PASSIVE RADON CONTROL SYSTEM N
CRAWL  SPACE FOR NEW CONSTRUCTION

NOTES:
1. NSTALL A LENGTH OF 3" OR 4" DIAMETER PERFORATED DRAW
  TIE HORIZONTALLY BENEATH THE SHEETWG  AND CONNECT
  TO THE "T" FITTNG WITH THE VERTICAL  STANOPPE THROUGH
  THE SOB.-GAS-RETARDER MEMBRANE. THIS HORIZONTAL PPE
  SHOULD NORMALLY  BE PLACED PARALLEL TO THE LONG
  DIMENSION OF THE HOUSE AND SHOULD EXTEND NO CLOSER
  THAN 6 FEET TO THE FOUNDATION WALL.

2. VENTILATE CRAWLSPACES IN CONFORMANCE WITH
  LOCAL COOES: VENTS SHALL BE OPEN TO THE
  EXTERIOR AND BE OF NONCLOSEA8LE DESIGN.
3. CRCUTS SHOULD BE A MINIMUM 15 AMP. 115 VOLT.
                                          EXHAUST OO'FROM OPEMNGS WTO
                                             ,    CONDITIONED SPACES  OF BUILDWG)
                                                12" M1N. ABOVE ROOF
    INTERIOR PARTITION —

LIVING AREA

    SEAL AROUND
    FLOOR  PENETRATIONS-

FLOORING
                        JOIST
  GRADE
  LEVEL
                           CAP BLOCK OR OTHER SEAL
                           ON HOLLOW  BLOCK WALLS
                          CRAWL  SPACE
                          NOTE 2
SOL-GAS-REJAROER MEMBRANE  SEALED AGAINST
WALL AND AROUND PENETRATIONS (MIN. 6-MIL
POLYETHYLENE SHEETING OR EQUIVALENT)

PERFORATED DRAIN
TILE: NOTE 1
                                                                                   •ELECTRICAL JUNCTION BOX
                                                                                    FOR FUTURE WSTALLATION
                                                                                    OF VENT FAN; NOTE 3.

                                                                               -ELECTRICAL JUNCTION BOX
                                                                                FOR FUTURE WSTALLATION
                                                                                OF WARNING DEVICE: NOTE 3.
                                                      SUPPORT
                                                      STRAPPING
   3"-4" DiA. VENT  PIPE
   (PVC  OR EQUIVALENT)

  •SEAL  MEMBRANE  AROUND
   PIPE PENETRATION

ADJOWING SHEETS OF
MEMBRANE OVERLAPPED
AND SEALED	>
                                                                             PVC T-FffTING (OR EQUIVALENT)
                                                                             TO  SUPPORT VENT PIPE

-------

-------
 PASSIVE SUB-SLAB DEPRESSURIZATION  RADON
 CONTROL SYSTEM FOR NEW  CONSTRUCTION

 NOTES:
 1 ALL CONCRETE SLABS THAT COME IN CONTACT WITH THE GROUND SHALL
   BE LAW OVER A GAS PERMEABLE MATERIAL MADE UP OF EITHER A MN1MUM
   4" THICK INFORM LAYER OF CLEAN AGGREGATE. OR A MINIMUM 4" THICK
   UNIFORM LAYER  OF SAND. OVERLAIN BY A LAYER OR STRPS OF MANUFACTURED
   MATTING DESIGNED TO ALLOW THE LATERAL FLOW  OF SOI GASES.

2. ALL CONCRETE FLOOR SLABS SHALL BE DESIGNED  AND CONSTRUCTED
   IN ACCORDANCE  WITH LOCAL BUILDING CODES. ADDITIONAL REFS:
   AMERICAN CONCRETE INSTITUTE PUBLICATIONS. "ACI302.1R" &
   "ACI332R". OR THE POST TENSIONNG  NSTITUTE MANUAL. "DESIGN
   AND CONSTRUCTION OF POST-TENSIONED SLABS ON GROUND".

3. ALL OPENINGS. GAPS AND JOINTS IN FLOOR AND WALL ASSEMBLIES IN
   CONTACT SOIL OR  GAPS  AROUND PIPES. TOILETS. BATHTUBS OR
   DRAINS PENETRATING THESE ASSEMBLIES SHALL BE FILLED OR CLOSED
   WITH MATERIALS  THAT PROVOE A PERMANENT AIR-TIGHT SEAL. SEAL
   LARGE  OPENINGS WITH NON-SHRINK MORTAR. GROUTS OR EXPANDING
   FOAM MATERIALS AND SMALLER GAPS WITH AN ELASTOMERIC  JOINT
   SEALANT. AS DEFINED IN ASTM C920-87.

4. VENT PIPES SHALL BE INSTALLED SO THAT ANY RAINWATER OR
   CONDENSATION DRAINS DOWNWARD WTO  THE  GROUND BENEATH THE
   SLAB OR SOIL-GAS-RETARDER MEMBRANE.

5. CIRCUITS  SHOULD BE A MINIMUM 15 AMP. 115 VOLT.
                                              EXHAUST (10'FROM OPENINGS INTO  .
                                                      CONDITIONED SPACES  OF BUILDWG)
                                                    12- MIN. ABOVE ROOF
                            JOIST
LIVING AREA


       INTERIOR PARTITION-

   FLOORING	1
                            JOIST
     GRADE
     LEVEL
  -CAP BLOCK  OR OTHER SEAL
   ON HOLLOW BLOCK WALLS

  -WATERPROOF SEALANT APPLED
   TO EXTERIOR WALLS

   SOIL-GAS-RETAROER MEMBRANE (MIN.
   6-MIL POLYETHYLENE  SHEETING OR
   EQUIVALENT): OVERLAP SEAMS 12" MIN.-
                              SEAL OPENINGS IN SLAB AND
                              AROUND PENETRATIONS: NOTE 3
                                                                                         ELECTRICAL JUNCTION BOX
                                                                                         FOR FUTURE INSTALLATION
                                                                                         OF VENT FAN; NOTE 5.

                                                                                    -ELECTRICAL JUNCTION BOX
                                                                                     FOR FUTURE WSTALLATION
                                                                                     OF WARNING DEVICE: NOTE 5.
                                                         - SUPPORT
                                                          STRAPPING
                                                                                    -3"-4" DIA, VENT PIPE
                                                                                     (PVC OR EQUIVALENT)
-SLAB: NOTE 2

-MIN. 4" THICK LAYER
 OF GAS PERMEABLE
 MATERIAL: NOTE 1
                                                                                    PVC T-FITTING (OR EQUIVALENT)
                                                                                    TO SUPPORT  VENT PIPE

-------

-------
ADDITIONAL COMPONENTS REQUIRED FOR ACTIVATION
OF PASSIVE SUB-SLAB  DEPRESSURIZATION  OR
CRAWLSPACE RADON CONTROL SYSTEM

NOTES:
1  INSTALL THE VENT  FAN IN THE VERTICAL RUN OF THE VENT PIPE.
   THE SIZE AND AIR MOVEMENT CAPACITY OF THE VENT FAN SHALL
   BE SUFFICIENT TO CREATE AND MAWTAJN A PRESSURE FIELD
   BENEATH THE SLAB OR CRAWLSPACE MEMBRANE  THAT IS LOWER
   THAN THE PRESSURE ABOVE THE SLAB OR MEMBRANE.

2.  ALL POSITIVELY PRESSURED PORTIONS OF THE VENT PPE AND
   FAN SHALL BE LOCATED OUTSIDE THE HABITABLE SPACE
   THE BUILDING.

3.  PROVIDE A VISIBLE  OR AUDIBLE WARNING  SYSTEM TO  •
   ALERT  THE BUILDING OCCUPANT IF THERE IS A LOSS
   OF PRESSURE OR AIR FLOW IN THE  VENT PIPE.
EXHAUST (10* FROM OPENINGS INTO
        CONDITIONED SPACES' OF BUILDING)
      12" MIN. ABOVE ROOF
            FAN COUPLING TO PIPE

                    ROOF BRACE
                                                  FAN; NOTE 1
                                                  & NOTE 2
                                                                                      ELECTRICAL
                                                                                      JUNCTION BOX
                                 LIVING AREA
                                                                                SYSTEM FAJLURE
                                                                                DEVICE: NOTE 3.
                               INTERIOR PARTITION

                           FLOORING

-------

-------