United States Office of EPA 520/1 -87-01 5
Environmental Protection Radiation Programs July 1987
Agency Washington, D.C. 20460
. , ___
jfeyiaed Sepbaiter, 1987
Radiation
«EPA Radon/Radon Progeny
Measurement Proficiency
Program
Cumulative Proficiency Report
(This publication valid through September 1988}
-------
-------
ERRATA SHEET
Radon/Radon Progeny Measurement Proficiency
(RMP) Program Proficiency Reports for
Round 4
For the Cumulative Proficiency Report (CPR), changes are as follows:
Table 1, page 7, "National" listing; next to Affiliated Building
Inspectors, Inc., add CC method.
Table 1, page 8, "National" listing; add Rosentiel Research Center
with CC method.
Table 1, page 9, "Colorado" listing; add M.V.E., Inc. with AT, CC
methods.
Table 2, page 38; under listing for Radon & Environmental
Professionals, change the first listed telephone number to (913) 749-
7420.
Table 2, page 43; under listing for Rogers & Associates Engineering
Corporation, change indicator for 11/86 Round, CC method to LI.
V '
Table 2, page 43; add listing for Rosentiel Research Center; Brandeis
University; 415 South Street; Waltham, MA 02154; Dr. Daniel Perlman,
(617) 736-2461; with LJl indicator under CC method for 5/87 Round.
Table 2, page 43; under listing for Ross Systems, Inc., change
telephone number to (201) 362-5571.
For all State Proficiency Reports (PR's), changes are as follows:
Table 1; next to listing for Affiliated Building Inspectors, Inc., add
CC method.
Table 1; under listing for Radon Alert Detection Center, change address
to: Post Office Box 323, Flourtown, PA 1°031.
Table 1; next to listing for Radonics, Inc. add AT method.
Table 1; add listing for: +Rosentiel Research Center; Brandeis
University; 415 South Street; Waltham, MA 02154; (617) 736-2461, with
CC method.
Table 1; under listing for Ross Systems, Inc., change telephone number
to (201) 362-5571.
-------
-------
For Colorado Proficiency Report, changes are as follows:
Table 1: add listing for: M.V.E., Inc.; 1911 Leiaray Street; Colorado
Springs", CO 80809; (303) 635-5736, with AT and CC methods.
For Kansas, Missouri, Nebraska, and Oklahoma Proficiency Reports (PR's), changes
are as follows:
Table 1; under listing for Radon and Environmental Professionals,
change first listed telephone number to: (913) 749-7420.
-------
-------
CUMULATIVE PROFICIENCY REPORT
(This publication is valid through February 1988)
EPA Test Round 4
Prepared by
Research Triangle Institute
Radon Technical Information Service
Research Triangle Park, NC 27709
Prepared for the
Office of Radiation Programs
U.S. Environmental Protection Agency
Washington, DC 20460
EPA Contract No.: 68-01-7350
July 1987
-------
-------
TABLE OF CONTENTS
Page
t ntroduct i on 1
Selection of Measurement Method ?
Program Requirements.... 5
Explanation of Acronyms.... 5
Table 1: Areas Serviced by Measurement
Coinpan i es 7
Table 2: Performance Results of Companies 24
141
-------
-------
INTRODUCTION
Recent public concern over the health
effects from exposure to radon has greatly
increased the demand for companies qualified to
measure radon and radon progeny In Indoor air.
In response to States' requests for assistance,
the U.S. Environmental Protection Agency's
Office of Radiation Programs has developed the
Radon/Radon Progeny Measurement Proficiency
(RMP) Program. Under this program, any company
offering measurement services directly, or
Indirectly through another company -- Is Invit-
ed to demonstrate its proficiency in measuring
radon gas and radon progeny levels.
The program's Immediate oblectlve Is to
assist States and the public In selecting com-
panies that have demonstrated competence in
measuring Indoor radon and radon orogeny. This
is achieved by evaluating, on a semiannual
basis, the proficiency of companies' detector
operations and the quality of their data man-
agement. The companies that demonstrate their
proficiency are listed In the RMP proficiency
reports. The program's long-term objectives
are to promote standard measurement procedures
among measurement companies and to establish
quality assurance procedures for all measure-
ment companies.
ThP RMP Program Is nnt designed for ac-
crediting measurement companies.HOT JOS? It
certify, recommend, nr endnrse participating
companies. The Inclusion of a company In this
report should not be interpreted as a certifi-
cation or accreditation of that company. This
report is only a source of measurement compa-
nies that have demonstrated capabilities for
measuring radon and radon progeny levels.
The testing periods are referred to as
test "rounds". Each round consists of two
tests <- a performance test and a follow-up
test. A company enrolls Its measurement
method(s) (e.g., activated charcoal adsorption)
for evaluation. EPA tells the company to sub-
mit a specific number and type of detectors
(e.g., five charcoal canisters) for exposure to
known levels of radon and radon progeny. After
exposure in a federal radon chamber, EPA re-
turns the detectors to the company without
revealing the radon gas or .radon progeny lev-
els. The company analyzes the detector(s) and
reports its measurement results to EPA. EPA
compares the measurement results with the known
levels of exposure. If a company falls any. of
the program requirements in the performance
test, It must retest in the follow-up test.
The same detector submittal and exposure proce-
dures are followed for the follow-up test.
Companies that fail this second attempt may
participate in the next test round.
Only companies having met all the program
requirements for a method In either the per-
formance or the follow-up test are listed in
this Cumulative Proficiency Report. The com-
panies that meet all the program requirements
in the initial performance test are listed with"
an "LI" Indicator under the appropriate meth-
od(s). Companies that meet all the require-
ments In the follow-up test are listed with an
"LA" indicator under the appropriate method(s).
A company's method that fails after having been
listed in a.previous round's report Is omitted
entirely from this report and will not be rein-
stated until Its next successful performance In
a round. When the method passes again, its
performance Indicators for the previous three
-------
rounds as well as for the present round will be
listed. Upon reinstatement, the round during'
which the method had failed will be narked with
an "NL" Indicator, signifying its omission from
that round's report.
Table 1 lists all the proficient companies
serving each State. Numerous companies distri-
bute mall-In detectors and make measurements
nationwide. The companies offering nationwide
service are under the "Nationwide" heading, and
precede the Individual State headings.
Table 2 lists the companies'^ performance
Indicators for each round over a two-year peri-
od. In addition, it Indicates If they are
"prlaary" or "secondary" companies, and shows
whether they have submitted acceptable quality
assurance (QA) plans.
A prlaary company either owns analysis
capabilities or makes all measurements and
analyses with Its own Instrumentation and oper-
ators. This type of company may or may not
offer aeasurement services directly to the
public. A secondary company's services may
range froa detector distribution to home In-
spection and consultation. This type of com-
pany aust use one of the primary companies for
its analyses. In a case where a company offers
primary services for one method but not anoth-
er, the perfornance indicators In Table 2 are
underscored to mark the method(s) for which It
Is a prlaary company. EPA has asked, but has
not required, that participating companies
subs It for review a copy of their QA plans. An
X under the column headed "QA Plan" in Table 2
Indicates that the company has submitted a plan
that compiles with the QA criteria recommended
by this program.
SELECTION OF MEASUREMENT METHOD
Several different measurement methods may
be used to determine the radon or radon progeny
concentrations In houses. In practice, the
choice of a method Is often dictated simply by
availability If an adequate method is
available, you use It. If alternative methods
are available, then the cost or the duration of
the measurement may become the deciding factor.
EPA has developed measurement protocols
for seven different methods, and believes that
any of them, when used In accordance with EPA
protocols, can produce valid results. This
does not mean that all measurements made ac-
cording to the suggested protocols will produce
results with Identical certainties. However,
it does mean that the listed methods are capa-
ble of producing adequate results for screening
or follow-up purposes.
Each method has Its own advantages and
disadvantages. Users must decide which method
is best suited to their situations. The fol-
lowing sections detail the characteristics of
the seven methods, pointing out some of the
advantages and disadvantages of each one. This
summary Is not exhaustive, but is intended to
guide the user in making an informed selection
of a measurement method.
Continuous Radon Monitoring (CR) and
Continuous Working-Level Monitoring (CW) -
These measurement methods are similar in
"; ,;rt ) fr/p^jvy
that they use an electronic detector to accumu-
late and store information related to the perl-
' : ' .si.j X'ift* v,i jnsftfisnaq JsrtJ
odlc (usually hourly) average concentrations of
-" " ' . >,- , :' ~, -r ... .», ; «,|
-------
guidelines fn the EPA protocol, and then turned
on, or programmed for, the desired operating
time a minimum of six hours for screening
and twenty-four hours for follow-up measure-
ments." "At the end of the-test, the monitor
must be retrieved, and the results must be
_analyzed by a skilled Instrument operator,
Advantages
Relatively short measurement duration.
Hourly results can track the variation
of concentrations in the house.
"'*' Very precise (most Models).
Results are available on-site (for CW).
Disadvantages
Relatively expensive, cost nay range
froi $100 to $300, depending on the
type of services provided.
Requires a skilled Instrument operator.
this, as does any short-term measure-
aent, requires careful control of
,;.. closed-house conditions twelve hours
before and during the test.
Because of the highly reactive nature
of radon progeny, the continuous
,,^working-1eve I measurements are much
more susceptible to sampling error than
radon gas measurements.
Aloha-Track Detection (AT)
The alpha-track method measures radon. An
AT detector Is a small sheet of special plastic
material enclosed in a filtered container. The
container collects the radon progeny on the
filter paper while the radon gas enters the
container. As the gas and some of the short-
lived progeny decay, they emit alpha particles
< '.. /,: oj ': ..! . ' '
that permanently mark the plastic sheet.-,.
Jo gfioIj-siJnsonoo sgeisv? (v; ;..,;,.
The detectors are Installed in the home
according to guidelines In the EPA protocol.
They are left for periods of up to three months
for screening and twelve months for follow-up
measurements. At the end of the desired test-
ing period,^ they must be returned to the dis-
tributor- or analytical laboratory for process-
ing and evaluation. , ,
Advantages , .
Relatively low-cost services; cost may
range from $20 to $60.
No special skills required for making
the measurement.
Can be distributed by maiI.
Completely passive, needs no external
power. ,
Can measure the long-term average con-
centratlons over a twelve-month period,
which is the optimal measurement of
long-term concentrations.
Disadvantages
Relatively long measurement period
necessary; three months Is the recom-
mended minimum for currently available
detectors.
Activated Charcoal Adsorption (CO
The charcoal adsorption method measures
radon gas. The detectors for this method
consist of variously configured containers
filled with a measured amount of activated
charcoal. The container Is often perforated or
screened to keep the charcoal from fall ing-out,
and to filter out radon progeny. All charcoal
adsorbers are stored In airtight containers
when not being used for sampling.
,Charcoal adsorbers can be received through
the mail from a distributor. They are .
installed,in the home for up to seven days
according, to guidelines in the EPA protocols.
-------
At the end of testing, an adsorber Is reseated
and returned to the distributor or analytical
laboratory for processing and evaluation.
Advantages
Low cost for services; costs may range
froH $10 to $25.
Can be distributed by mall.
No special skills needed for making the
ieasurement.
Coapletely passive, needs no external
power.
With proper analysis, can yield precise
results.
Disadvantages
Scne charcoal adsorbers are more sensi-
tive than others to temperature and
hunidity.
United to short-tern testing.
Requires, as does any short-term meas-
urement , careful control of closed-
house conditions twelve hours before
and during the test.
Radon Prooenv Integrating Sampling Unlt-RPISU
(RP)
The RP method measures radon progeny. RP
detectors have a flow-rate air pump that pulls
air continuously through a detector assembly.
Depending on the node I, the unit can be in-
stalled and operated by homeowners or skilled
operators for three days or longer, according
to guidelines In the EPA protocol. At the end
of that time, the homeowner sends it to the
distributor, or an operator removes the unit
and returns It to the analysis laboratory for
processing and evaluation.
Advantages
Directly measures concentrations of
radon decay products.
Relatively short measurement period.
The detector assembly and some entire
units can be sent by mail.
There is extensive experience in the
use of RPISU's; therefore, measurement
errors are well established.
Disadvantages
Relatively expensive; cost may range
from $40 to $150, depending on type of
service provided.
May be limited to locations with AC
power.
Some units may be installed and picked
up by a skilled Instrument operator.
Because of the highly reactive nature
of radon decay products, measurements
are much more susceptible to sampling
error than radon gas measurements.
Grab Radon (GR> and Grab Radon Progenv(GH)
The grab sampling methods measure concen-
trations of radon gas or radon progeny concen-
trations. The radon grab sample is collected
in as special flask holding 100 to 2,000 cubic
centimeters of air. The radon progeny grab
sample is collected by drawing air through a
filter, upon which progeny, if present in the
air, are collected. Both samples can be ac-
quired simultaneously with some detector sys-
tems. All sampling should be done in accor-
s
dance with guidelines in the EPA protocols.
For results of the grab radon test, opera-
tors must return to their offices to analyze
the exposed detectors, and must delay the anal-
ysis for at least four.hours after the testing.
-------
For most grab work Ing-1 eve I tests (radon proge-
ny), operators can perform the analysis on
location in an hour or less.
Advantages
Results are quickly obtained.
Equipment can be portable.
Some detector systems can sample both
radon gas and radon progeny
simultaneously.
Can acquire and evaluate several
samples per day.
Conditions during the measurement are
known to the operator.
Disadvantages
Relatively expensive; costs may range
from $80 to $300, depending on the type
of services offered.
Very short measurement periods may not
be representative of the long-term
average concentrations.
Requires a skilled operator.
Requires, as does any short-term meas-
urement, careful control of closed-
house conditions twelve hours before
and during the test.
Because of the highly-reactive nature
of radon progeny, grab radon progeny
measurements are much more susceptible
to sampling error than radon gas
measurements.
PROGRAM REQUIREMENTS
For each method, participants must send
with their applications a copy of the operating
instructions they provide homeowners and/or
those'.used by an instrument operator. These
instrtftjt-i'oiis must reflect the measurement
procedures found in the EPA documents,'"Interim
Indoor Radon and Radon Decay Product Measure-
ment Protocols" and "Interim Protocols for
Screening and Follow-up Radon and Radon Decay
product Measurements". They must be accepted
by, and on file with, EPA by the end of the
follow-up test.
Once enrolled, a company must meet EPA's
minimum screening-measurement requirements for
each method. A company must meet all detector
and analysis result deadlines as listed on the
program schedule. Applications, detectors, and
analyses reporting forms received after, a
scheduled deadline will not be considered in
the performance evaluation process. A com-
pany's detector(s) must be tested every round
to maintain its proficiency listing.
EXPLANATION OF ACRONYMS
Methods Unit?
AT - Alpha-track Detection (pCi/l)
CC - Activated Charcoal Adsorption (pCI/l)
CR - Continuous Radon Monitoring (pCi/l)
CW - Continuous Working-Level
Monitoring (WL)
GR - Grab Radon Sampling (pCl/l)
GH - Grab Working-Level Sampling (WL)
RP - Radon Progeny Integrated
Sampllng/RPlSU - (WL)
Measurement Units
pCi/l - Picocurles per liter air, radon gas
measurement units.
WL - Work ing-1 eve I, radon progeny
measurement units.
HAfIn it Ion of Performance Indicators .
L1 - Signifies a company's ability to meet all
program requirements with the given meas-
urement method in the performance test.
LA - Signifies a company's ability to pass all
program requirements with the given method
only after the follow-up test.
-------
NL - Signifies a method's omission from the CPR
because of unsuccessful participation.
This Indicator is only used when a method
has passed a round, then failed, resulting
In Its performance record being omitted
froa a previous report, and has now passed
again. "NL" Is used In the method's
reinstated performance record.
Others
QA - Quality Assurance.
DT - Detector(s) damaged or lost through no
fault of the participant.
-------
TABLE 1
MEASUREMENT COMPANIES BY SERVICE AREAS
* Company . Measurement Methods
Company
Measurement Methods
NATIONAL
ABE Radiation Measurements Lab
ARIX Sciences, Inc.
Accu-Test
Accurate Air Testing
Advanced Radiation Monitoring Serv.
Affiliated Building Inspectors, Inc
Air Chek, Inc.
Air Sciences, Inc/Overman Assoc.
Air-N-Sol Corporation
Alpha Control, Inc.
Alpha Spectra
Amersham Corporation
Appalachian Envir. Testing Inc
Applied Energy Company
Applied Health Physics Inc.
Applied Radon Test. & Reduct'n
Barcon, Inc.
Barringer Laboratories, Inc.
Battelle
Bowling Green Radon Laboratory
CDS Technologies, Inc.
CMT Inc.
Camp Dresser & McKee Inc.
Camroden Associates
Canberra Industries Inc.
Capital Materials Testing Inc.
Centarus Corporation
+ Chemical Engineering Unit, RTI
Clean Air Engineering, Inc.
Con-Test, Inc.
Core Laboratories Inc
EKS RadTech
ENV Services, Inc.
EberIi ne Instrument Corp.
Electro Mechanical Concepts
EnRad, Inc./Rad. T. & Eng. Inc
Envirohazards Management, Inc.
CC
GR.OW
AT.CC
CC
CC.
AT
CC
CC
GR,GW,CW
AT,CC
CC
AT.CC
AT
CC
AT,CC,CR,GR,GW,CW
CC
AT,CC
CC
AT,CC,CR
CC
AT,CC
CC
CC,CR,GR,GW,CW
AT,CC,CR,GR
CC
CC
CC
CR
CC
GW
GR
CC
GW
CR
CC
AT,CC
CC
Environ. Detection Associates
Environmental Chemistry
Enviroserv
Env i rotest
Futura Medical Systems, Inc.
GEOMET Technologies, Inc.
Garden St. Home Inspection Svc
General Health Physics Inc.
Health Physics Associates, Inc.
Health Physics Associates, Ltd.
Health and Safety Associates
Home Inspection Service, Inc.
Home Sentry Inc.
Home Testing Service
Hudson Valley Radon Testing Corp.
Infiltec
Inspex of Boulder, Inc.
JRW Industries, Inc.
K & J Solar Service
KSE, Inc.
Key Technology, Inc.
Lapteff Associates
f MIT/MIT Radon Project
t- Maine Public Health Laboratory
NODAR, Inc.
National Radon Control, Inc.
Niton Corporation
Northeast Radon Testing Svc., Inc.
Northeastern PA Envir. CounciI
Nuclear Sources ft Services Inc.
Nucleon Lectern Associates, Inc.
0. K. Rems Corp.
+ Oak Ridge Assoc. Universities
Phoenix Labs
Princeton Testing Laboratory
Pylon Electronic Development
Pyramid Environmental Systems, Inc.
R.A.D. Service & Instruments Ltd.
RAD Environmental Services
RAF Engineering
CC
CC
CC
CC
CC
AT,CC
CC
CC
CC
CC
AT,CC
CC
CC
CC
CC
CC,GR
CC
CC
CC
CC
CC
CC
CC,GR
CC
GW
RP
CC,GR
CC
CC
CC
AT,CC,GR,CW ,: !
CC
CC
CC
AT,CC ;
GW,CW
CW ......
RP ; ,
AT,CC,CR,GR,GW,CW
AT.CC
* For addresses, phone numbers, and performance records see Table 2.
+ Non-cotrmercia! laboratory for research purposes or State agencies' assistance only.
-------
TABLE 1
MEASUREMENT COMPANIES BY SERVICE AREAS
* Company
Measurement Methods
oc
RISE
Rad-Elec, Inc.
Radiation Data
Radiation Protection Services
Radiation Safety Engineering
Radiation Safety Services, Inc.
Radiation Service Organization
Radon Alert Detection Center
Radon Ana lists, Inc.
Radon Analysis Incorporated
Radon Consultants, Inc., VA
Radon Detection Services, Inc.,-GA
Radon Detection Services, Inc., MD
Radon Detection Services, Inc., NJ
Radon Detection Services, Inc., PA
Radon Detection Systems, CO
Radon Detection and Control
Radon Engineering Services Inc
Radon Engr, a Unit of PSI Engr, Inc
Radon Environ. Monitoring, Inc
Radon Measurement and Services
Radon Measurements Inc.
Radon Project, The
Radon Research Group
Radon Safety Services, Inc.
Radon Surveys, Div. Cope Tech Svcs
Radon Testing Corp. of America RTCA
Radon Testing Svc, Pittsburgh, PA
Radon Testing Svcs, Baltimore, MD
Radonics, Inc.
Radonix
Real Estate Support Services
' Recon Systems, Inc.
' Rogers & Assoc. Engineering Corp.
Ross Systems, Inc.
Roy F. Weston, Inc.
Ryan Nuclear Laboratories
Scientific Testing Associates
SepTech
Southern Radon Services, Inc.
CC
AT,CC
CC
CC
CC
AT.GW
CC
AT,CC
CC
CC
AT.CC
AT,CC
AT,CC,GR,GW,CW
AT,CC
AT,CC,GW,CW
AT,CC,GW
CC
CC
AT,CC
AT
AT,CC,GR,GW
AT,CC
CC
AT
CC,RP
CC
CC
CC
CC
AT,CC
CC
CC
AT.CC
AT,CC,GR
AT,CC
GR,GW
CC
CC
CC,GR
CC,CW
* Company
Measurement Methods
Standor Radon Detection AT,CC
TCS Industries, Inc. CC
TEQ Corporation AT,CC,CR,CW
TMA/Eberline, Health Physics CC,GR
Teledyne Isotopes CC
Terradex Corporation AT
Testing 1. 2. 3 AT,CC
+ US Army Envir. Hygiene Agency CC
US E.P.A., Las Vegas, NV GR
US Radon Testing Service CC
Univ of Texas School of Pub. Health CC
Univ. of Pittsburgh Radon Project AT,CC
f University of Lowell CC
Virginia Radon Service, Inc. CC
W. S. Fleming and Associates AT,CC,CR,GR,CW
* Wi Ikes College AT,CC,CR,GR,CW
Wright Lab Services, Inc. CC
ALABAMA
Advanced Materials Enterprises, Inc CC
Cavin Analytical Consultants CC,GR,GW
Chem-Safe Inc. CC
Energy Systems, Inc AT,CC,CR,GR
Environmental Radon Measurements AT
Enviroserv-Radon Detect, of AL ' CC
Scientific Analysis, Inc. CC
Sorensen Enterprises, Inc. CC
ALASKA
Cavin Analytical Consultants CC,GR,GW
Chem-Safe Inc. CC
Columbia Radiological Test Lab AT
Madrona Divirsified, Inc. CC
Radon Testing Svc, Englewood, CO CC,GW
West Coast Environmental Services CC
ARIZONA
* For addresses, phone numbers, and performance records see Table 2.
+ Non-commercial laboratory for research purposes or State agencies' assistance only.
-------
TABLE 1
MEASUREMENT COMPANIES BY SERVICE AREAS
* Company,
Measurement Methods
* Company
Measurement Methods
AAAirscan Engineering Corp. AT,CC
Cavin Analytical Consultants CC,GR,GW
Chem-Safe Inc. .- . CC
Environmental Engineering ft Testing CC
Hazen Research, Inc. CC
Integral Resources, Inc. AT
Madrona Divirsified, Inc. CC
Radon Measurement and Control AT
Radon Screening Service, Inc. AT,CC
Radon Testing Svc, Englewood, CO CC,GW
Scientific Analysis, Inc. CC
Sorensen Enterprises, Inc. CC
West Coast Environmental Services CC
ARKANSAS
ACI Chemical Co. In. d/b/a ACI Insu CC
Cavin Analytical Consultants CC,GR,GW
Chem-Safe Inc. CC
Scientific Analysis, Inc. CC
Sorensen Enterprises, Inc. CC
CALIFORNIA
AAAirscan Engineering Corp. AT,CC
ABMS, Inc. GW
+ CA State Dept. of Health Serv. CC,GR
Chem-Safe Inc. CC
Environmental Engineering ft Testing CC
Faytek Incorporated AT,CC
Hazen Research, Inc. CC
Integral Resources, Inc. AT
Madrona Divirsified, Inc. CC
Radon Testing Svc, Englewood, CO CC,GW
Scientific Analysis, Inc. CC
Sorensen Enterprises, Inc. CC
West Coast Environmental Services CC
COLORADO
AAAirscan Engineering Corp. AT,CC
Alpha Radon Screening ft Home CC
Cavin Analytical Consultants CC,GR,GW
Chem-Safe Inc. CC
Colorado Radon Engineering Inc CC
Environmental Engineering ft Testing CC
Ero Resources Corporation CC
Faytek Incorporated AT,CC
Geo-Chek, Inc. CC.CW
Hazen Research, Inc. CC
Madrona Divirsified, Inc. CC
Natural Resource Technologies CC
Radon Consultants, CO AT,CC
Radon Env. Test Experts, Inc.- CC
Radon Measurement ft Control CC
Radon Measurement and Control AT
Radon Screening Service, Inc. AT,CC
Radon TNT CC,GW
Radon Testing Svc, Englewood, CO CC,GW
Rocky Mountain Radon Testing CC
Scientific Analysis, Inc. CC
Sorensen Enterprises, Inc. CC
Timber line Radon Service CW
Univ. of Colorado-Colorado Springs CC
West Coast Environmental Services CC
CONNECTICUT
A-l Sherlock Home Inspectors CW
AAAirscan Engineering Corp. AT,CC
AIDCO Maine Corp CC
Biomedical Toxicology Assoc. CC
Boxford Radon Lab (B.R.L.) CC
CDS Technologies, Inc. CW
Cavin Analytical Consultants CC,GR,GW
Commonwealth Eng. ft Technology CC
Continental Environment Company AT,CC
Ecological Interactions, Inc. AT,CC
Environmental Control Technologies CW
Environmental Radioactivity Measure CR,GR
* For addresses, phone numbers, and performance records see Table 2.
+ Non-commercial laboratory for research purposes or State agencies' assistance only.
-------
TABLE 1
MEASUREMENT COMPANIES BY SERVICE AREAS
* Company
Measurement Methods
* Company
Measurement Methods
Environmental Sys. Service Ltd
Environmental Systems Service
Enviroserv
Faytek Incorporated
FederaI NucIi de Mon i tors
Gesell Institute, The
MRC Home Inspections
Microbac Labs, Erie Testing Lab Div
Microbac Labs, Hanover, PA
Microbac Labs, MA Testing Division
Microbac Labs, New Castle, PA
Microbac Labs, Pittsburgh, PA
Microbac Labs, Schiller Div.
Microbac Labs, Seaway Div
New England Radon, LTD.
Protect-A-Home
Radiation Safety Associates, Inc.
Radon Detection Services, Inc., NJ
Radon Detection, Inc.
Radon Engr, a Unit of PSI Engr, Inc
Radon Inspection Service
Radon Management Laboratories
Radon Safety Services, Inc.
Radon Technologies Inc.
Radonics, Inc.
Res-I-Tec
Residential Radon Test Service
Ross Systems, Inc.
Scientific Analysis, Inc.
Shotwell Associates
Sorensen Enterprises, Inc.
DELAWARE
AAAirscan Engineering Corp.
ABE Radiation Measurements Lab
AIDCO Maine Corp
Alpha-Ban
Biomedical Toxicology Assoc.
CDS Technologies, Inc.
AT,CC
GR,GW,CW
CC
AT,CC
CC
CW
Cavin Analytics! Consultants CC,GR,GW
Commonwealth Eng. t Technology CC
Ecological Interactions, Inc. AT,CC
Environmental Sys. Service Ltd CC
Environmental Systems Service CC
Env i roserv CW
Health Physics Associates, Inc. GR,GW,CW
Microbac Labs, Erie Testing Lab Div CC
Microbac Labs, Hanover, PA CC
Microbac Labs, MA Testing Division CC
Microbac Labs, New Castle, PA CC
Microbac Labs, Pittsburgh, PA CC
Microbac Labs, Schiller Div. CC
Microbac Labs, Seaway Div CC
R.J. Moore & Associates, Inc. AT,CC
Radon Testing Svcs, Princeton, NJ CC
Radonics, Inc. GW,CW
Safe Shelter Environmental CW
Scientific Analysis, Inc. CC
ShotwelI Associates GW,CW
Sorensen Enterprises, Inc. CC
U.S. Toxic Substance Testing Bureau CW
DISTRICT OF COLUMBIA
AAAirscan Engineering Corp. AT,CC
ABE Radiation Measurements Lab GR,GW,CW
AIDCO Maine Corp CC
Abionics, Ltd. AT,CC
Alpha Control, Inc. GW
Alpha-Ban AT,CC
Appalachian Envir. Testing Inc CW
Biomedical Toxicology Assoc. CC
Cavin Analytical Consultants CC,GR,GW
Commonwealth Eng. ft Technology CC
Continental Environment Company AT,CC
Environmental Sys. Service Ltd CC
Environmental Systems Service CC
Enviroserv CW
Federal NucIide Monitors CC
* For addresses, phone numbers, and performance records see Table 2.
+ Non-commercial laboratory for research purposes or State agencies' assistance only.
-------
- ' TABLE 1 .
MEASUREMENT COMPANIES BY SERVICE AREAS
*Company
Measurement Methods
* Company
Measurement Methods
: Fores i ght Eng i neer i ng, Inc., VA CC
Health Physics Associates, Inc. GR,GW,CW
; Home Sure Inspections, Inc. GR
- Microbac Labs, Erie Testing Lab Div CC
Microbac Labs, Hanover, PA CC
Microbac Labs, MA Testing Division CC
Microbac Labs, New Castle, PA CC
Microbac Labs, Pittsburgh, PA CC
Microbac Labs, Schiller Div. CC
. Microbac Labs, Seaway Div CC
, R.J. Moore & Associates, Inc. AT,CC
RADON Home Inspection Service GW
Radon Engr, a Unit of PSI Engr, Inc CW
Radon Management Company CC
Radonics, Inc. GW,CW
Scientific Analysis, Inc. ; CC
Sorensen Enterprises, Inc. . CC
Terradynamics Corporation AT
West Coast- Environmental Services CC
FLORIDA
Microbac Labs, Seaway Div CC
Radon Engr, a Unit of PSI Engr, Inc CW
Radon Mitigators, Inc. CC
Scientific Analysis, Inc. CC
Sorensen Enterprises, Inc. CC
West Coast Environmental Services CC
GEORGIA
AAAirscan Engineering Corp. 'i AT,CC
AIDCO Maine Corp . CC
Advanced Materials Enterprises, Inc CC
Carolina Radon .Consultants CC
Cavin Analytical Consultants CC,GR,GW
Commonwealth Eng. ft Technology CC
Environmental Radon Measurements AT
Environmental Sys. Service Ltd CC
Environmental Systems Service CC
Enviroserv-Radon Detect, of AL CC
Microbac Labs, Erie Testing Lab Div CC
Microbac Labs, Hanover, PA CC
Microbac Labs, MA Testing Division CC
AAAirscan Engineering Corp.
AIDCO Maine Corp
Cavin Analytical Consultants
Commonwealth Eng. & Technology
Continental Environment Company
Ecological Interactions, Inc.
Environmental Radon Measurements
Environmental Sys. Service Ltd
Environmental Systems Service
Enviroserv-Radon Detect, of AL
Faytek Incorporated
Federa 1 Nuc 1 i de Moh i tors -
Microbac Labs, Erie Testing Lab Div
Microbac Labs, Hanover, PA
Microbac Labs, MA Testing Division
Microbac Labs, New Castle, PA
Microbac Labs, Pittsburgh, PA
Microbac Labs, Schiller Div.
AT,CC
CC
CC,GR,GW
CC
AT.CC
AT,CC
AT
CC
CC
CC
AT,CC ,
CC
CC
CC
CC
CC
CC
CC
Microbac Labs, New Castle, PA
Microbac Labs, Pittsburgh, PA
Microbac Labs, Schi 1 ler Div.
Microbac Labs, Seaway Div
Radon Measurement & Control
Scientific Analysis, Inc.
Sorensen Enterprises, Inc.
HAWAII
AAAirscan Engineering Corp.
Chem-Safe Inc.
IDAHO
Cavalier Corporation
Chem-Safe Inc.
Faytek Incorporated
CC
CC
CC
CC
CC
CC
CC
AT,CC
CC
CC
CC
AT.CC
For addresses, phone numbers, and performance records see Table 2.
Non-commercial laboratory for research purposes or State agencies' assistance only.
-------
TABLE 1
MEASUREMENT COMPANIES BY SERVICE AREAS
* Company
Measurement Methods
* Company
Measurement Methods
Integral Resources, Inc. AT
Madrona Divirsified, Inc. CC
+ Nuclear Radiation Center CC
Radon Screening Service, Inc. AT,CC
Radon Testing Svc, Englewood, CO CC,GW
Scientific Analysis, Inc. CC
Sorensen Enterprises, Inc. CC
ILLINOIS
AIDCO Maine Corp CC
Cavin Analytical Consultants CC,GR,CW
Chem-Safe Inc. CC
Columbia Radiological Test Lab AT
CommonweaIth Eng. ft Techno Iogy CC
Energy Marketing Midwest, Inc CC
Environmental Engineering ft Testing CC
Environmental Risk Consultants, Inc CC,GW
Environmental-'Sys. Service Ltd CC
Environmental Systems Service CC
Enviroserv-Radon Detect, of OH CC
Home Buyers Inspection Service CC
Hoosier Environmental CC
* IL Dspt. of Nuclear Safety AT,CC,GR,GW,CW
Microbac Labs, Erie Testing Lab Oiv CC
Microbac Labs, Hanover, PA CC
Microbac Labs, MA Testing Division CC
Microbac Labs, New Castle, PA CC
Microbac Labs, Pittsburgh, PA CC
Microbac Labs, Schiller Div. CC
Microbac Labs, Seaway Div CC
Radon Consultants, CO AT,CC
Radon Detection Specialists CC
Radon Engr, a Unit of PSI Engr, Inc CW
Radon Surveys, Div. Alpha Tech Corp GW
Residential Radon Measurements AT,CC
Scientific Analysis, Inc. CC
Sorensen Enterprises, Inc. CC
"INDIANA
Cavin Analytical Consultants CC,GR,GW
Chem-Safe Inc. CC
Commonwealth Eng. ft Technology CC
Environmental Engineering A Testing CC
Environmental Sys. Service Ltd CC
Environmental Systems Service CC
Enviroserv-Radon Detect, of OH CC
Home Buyers Inspection Service CC
Hoosier Environmental CC
Insul-Tech, Inc. CC
Microbac Labs, Erie Testing Lab Div CC
Microbac Labs, Hanover, PA CC
Microbac Labs, MA Testing Division CC
Microbac Labs, New Castle, PA CC
Microbac Labs, Pittsburgh, PA CC
Microbac Labs, Schiller Div. CC
Microbac Labs, Seaway Div CC
Rad-Test, Inc. CC
Radon Detection Specialists CC
Radon Surveys, Div: Alpha Tech Corp GW
Scientific Analysis, Inc. CC
Sorensen Enterprises, Inc. CC
IOWA
AIDCO Maine Corp CC
Cavin Analytical Consultants CC,GR,GW
Chem-Safe Inc. ' CC
Columbia Radiological Test Lab AT
Commonwealth Eng. ft Technology CC
Energy Marketing Midwest, Inc CC
Environmental Sys. Service Ltd CC
Environmental Systems Service CC
Frazier Co., The CC
Microbac Labs, Hanover, PA CC
Microbac Labs, MA Testing Division CC
Microbac Labs, New Castle, PA CC
.Microbac Labs, Pittsburgh, PA CC
Microbac Labs, Schiller Div. CC
* For addresses, phone numbers, and performance records see Table 2.
+ Non-commercial laboratory for research purposes or State agencies' assistance only.
-------
TABLE 1
MEASUREMENT COMPANIES BY SERVICE AREAS
Company Measurement Methods
* Company
Measurement Methods
Microbac Labs, Seaway Div CC
Scientific Analysis, Inc. CC
Sorensen Enterprises, Inc. CC
KANSAS
Alpha Radon Screening & Home CC
Cavin Analytical Consultants CC,GR,GW
Chem-Safe Inc. cc
Colorado Radon Engineering Inc CC
Columbia Radiological Test Lab AT
Environmental Engineering ft Testing CC
+ KS Dept. of Health & Environ. CC
: Radon & Environ. Professionals AT,CC
Radon Testing Svc, Englewood, CO CC,GW
Scientific Analysis, Inc. CC
Sorensen Enterprises, Inc. CC
KENTUCKY
AIDCO Maine Corp CC
Advanced Materials Enterprises, Inc CC
Cavin Analytical Consultants
Chem-Safe Inc.
Commonwealth Eng. ft Technology
Energy Systems, Inc
Environmental Radon Measurements
Environmental Sys. Service Ltd
Environmental Systems Service
Enviroserv-Radon Detect, of OH
Hoosier Environmental
Insul-Tech, Inc.
CC,GR,GW
CC
CC
AT,CC,CR,GR
AT
CC
CC
CC
CC
CC
Microbac Labs, Erie Testing Lab Div CC
Microbac Labs, Hanover, PA
Microbac Labs, MA Testing Division
Microbac Labs, New Castle, PA
Microbac Labs, Pittsburgh, PA
Microbac Labs, Schiller Div.
Microbac Labs, Seaway Div
Rad-Test, Inc.
CC
CC
CC
CC
CC
CC
CC
Radon Measurement ft Control CC
Scientific Analysis, Inc. CC
Sorensen Enterprises, Inc. CC
LOUISIANA
Cavin Analytical Consultants CC,GR,GW
Chem-Safe Inc. CC
Environmental Radon Measurements AT
Enviroserv-Radon Detect, of AL CC
Microbac Labs, Erie Testing Lab Div CC
Scientific Analysis, Inc. CC
Sorensen Enterprises, Inc. CC
MAINE
AAAirscan Engineering Corp. AT,CC
AIDCO Maine Corp CC
. Biomedical Toxicology Assoc. CC
Boxford Radon Lab (B.R.L.) CC
Cavin Analytical Consultants CC.GR.GW
Commonwealth Eng. & Technology CC
Environmental Control Technologies CW
Environmental Sys. Service Ltd CC
Environmental Systems Service CC
Federal NucIide Monitors CC
Microbac Labs, Erie Testing Lab Div CC
Microbac Labs, Hanover, PA CC
Microbac Labs, MA Testing Division CC
Microbac Labs, New Castle, PA CC
Microbac Labs, Pittsburgh, PA CC
Microbac Labs, SchiIler Div. CC
Microbac Labs, Seaway Div CC
New England Radon, LTD. CC
Radon Detection, Inc. CR
Radon Engr, a Unit of PSI Engr, Inc CW
Radon Inspection Service GR,GW
Radon Registry CC
Radonics, Inc. GW,CW
Residential Radon Test Service CC
* For addresses, phone numbers, and performance records see Table 2.
+ Non-commercial laboratory for research purposes or State agencies' assistance only.
-------
TABLE 1
MEASUREMENT COMPANIES BY SERVICE AREAS
* Company
Scientific Analysis, Inc.
Sorensen Ehterpi ises, Inc.
MARYLAND
Measurement Methods
CC
CC
AAAirscan Engineering Corp. AT,CC
ABE Radiation Measurements Lab GR,GW,CW
AIOCO Maine Corp CC
Abionics, Ltd. AT,CC
Alpha Control, Inc. QW
Alpha-Ban AT,CC
Appalachian Envir. Testing Inc CW
Biomedical Toxicology Assoc. CC
CDS Technologies, Inc. CW
Cavin Analytical Consultants CC,GR,GW
Commonwealth Eng. ft Technology CC
Continental Environment Company AT,CC
Ecological Interactions, Inc. AT,CC
Environmental Engineering ft Testing CC
Environmental Radioactivity Measure CR,GR
Environmental Sys. Service Ltd CC
Environmental Systems Service CC
Env i roserv CW
Federal Nuclide Monitors CC
Foresight Engineering, Inc., VA CC
Garco Research Company CC
Health Physics Associates, Inc. GR,OSW,CW
Home Sure Inspections, Inc. GR
Microbac Labs, Erie Testing Lab Div CC
Microbac.Labs, Hanover, PA CC
Microbac Labs, MA Testing Division CC
Microbac Labs, New Castle, PA CC
Microbac Labs, Pittsburgh, PA CC
Microbac Labs, Schiller Div. CC
Microbac Labs, Seaway Div CC
R.J. Moore ft Associates, Inc. AT,CC
RADON Home Inspection Service GW
Radon Engr, a Unit of PSI Engr, Inc CW
Radon Management Company CC
Radon Mitigators, Inc. CC
* Company
Measurement Methods
Radonics, Inc. GW CW
Scientific Analysis, Inc. CC*
ShotwelI Associates CW
Sorensen Enterprises, Inc. CC
Terradynamics Corporation AT
West Coast Environmental Services CC
MASSACHUSETTS
AAAirscan Engineering Corp. AT,CC
AIDCO Maine Corp CC
Biomedical Toxicology Assoc. CC
Boxford Radon Lab (B.R.L.) CC
Cavin Analytical Consultants CC,GR,GW
Commonwealth Eng. A Technology CC
Environmental Control Technologies CW
Environmental Sys. Service Ltd CC
Environmental Systems Service CC
Enviroserv CW
Federal Nuclide Monitors CC
Foresight Engineering, Inc., VA CC
Microbac Labs, Erie Testing Lab Div CC
Microbac Labs, Hanover, PA CC
Microbac Labs, MA Testing Division CC
Microbac Labs, New Castle, PA CC
Microbac Labs, Pittsburgh, PA CC
Microbac Labs, Schiller Div. CC
Microbac Labs, Seaway Div CC
New England Radon, LTD. CC
Radiation Safety Associates, Inc. CC
Radon Detection, Inc. CR
Radon Engr, a Unit of PSI Engr, Inc CW
Radon Inspection Service AT,CR,GR,GW
Radon Registry CC
Radon Safety Services, Inc. CW
Radon Technologies Inc. AT,CC,GR
Radon X Company, Inc., The GW
Radonics, Inc. GW,CW
Residential Radon Test Service CC
Scientific Analysis, Inc. CC
* For addresses, phone numbers, and performance records see Table 2.
+ Non-commercial laboratory for research purposes or State agencies' assistance only.
-------
TABLE 1
MEASUREMENT COMPANIES BY SERVICE AREAS
* Company
Sorensen Enterprises, Inc.
MICHIGAN
Measurement Methods
CC
* Company
Measurement Methods
AIDCO Maine Corp
Air-Tight of Genesee
Cavin Analytical Consultants
Chem-Safe Inc.
Commonwealth Eng. ft Technology
Environmental Sys. Service Ltd
Environmental Systems Service
Enviroserv-Radon Detect, of OH
Hoosier Environmental
Insul-Tech, Inc.
Microbac Labs, Hanover, PA
Microbac Labs, MA Testing Division
Microbac Labs, New Castle, PA
Microbac Labs, Pittsburgh, PA
Microbac Labs, Schiller Div.
Microbac Labs, Seaway Div
Radon Surveys, Div. Alpha Tech Corp
Scientific Analysis, Inc.
Sorensen Enterprises, Inc.
MINNESOTA
AAAirscan Engineering Corp.
Cavin Analytical Consultants
Chem-Safe Inc.
Energy Marketing Midwest, Inc
Enviroserv-Radon Detect, of OH
Madrona Divirsified, Inc.
Radon Measurement ft Control
Scientific Analysis, Inc.
Shotwe11 Assoc i ates
Sorensen Enterprises, Inc.
West Coast Environmental Services
MISSISSIPPI
CC
CC
CC,GR,GW
CC
CC
CC
CC
CC
CC
ec
CC
CC
CC
CC
CC
CC
GW
CC
CC
AT,CC
CC,GW
CC
CC
CC
CC
CC
CC
GW
CC
CC
Advanced Materials Enterprises, Inc CC
Cavin Analytical Consultants CC,GR,GW
Chem-Safe Inc. CC
Environmental Radon Measurements AT
Enviroserv-Radon Detect, of AL CC
Scientific Analysis, Inc. CC
Sorensen Enterprises, Inc. CC
MISSOURI
ACI Chemical Co. In. d/b/a ACI Insu CC
Cavin Analytical Consultants CC,GR,GW
Chem-Safe Inc. CC
Columbia Radiological Test Lab AT
Environmental Engineering ft Testing CC
Radon ft Environ. Professionals AT,CC
Radon Testing Svc, Englewood, CO CC,GW
Residential Radon Measurements AT,CC
Scientific Analysis, Inc. CC
Sorensen Enterprises, Inc. CC
MONTANA
Cavin Analytical Consultants CC,GR,GW
Chem-Safe Inc. CC
Environmental Engineering ft Testing CC
Faytek Incorporated
Integral Resources, Inc.
Madrona Divirsified, Inc.
Radon Consultants, CO
Radon Screening Service, Inc.
Radon Testing Svc, Englewood, CO
Scientific Analysis, Inc.
Sorensen Enterprises, Inc.
NEBRASKA
AAAirscan Engineering Corp.
Alpha Radon Screening ft Home
Cavin Analytical Consultants
AT,CC
AT
CC
AT,CC
AT,CC
CC,GW
CC
CC
AT,CC
CC
CC,GR,GW
* For addresses, phone numbers, and performance records see Table 2.
+ Non-conmercial laboratory for research purposes or State agencies' assistance only.
-------
TABLE 1
MEASUREMENT COMPANIES BY SERVICE AREAS
* Company
Measurement Method*
Chem-Safe Inc. CC
Colorado Radon Engineering Inc CC
Columbia Radiological Test Lab AT
Energy Marketing Midwest, Inc CC
Frazier Co., The CC
Radon ft Environ. Professionals AT,CC
Radon Testing Svc, Englewood, CO CC,GW
Scientific Analysis, Inc. CC
Sorensen Enterprises, Inc. CC
NEVADA
AAAirscan Engineering Corp. AT,CC
Cavin Analytical Consultants CC,GR,GW
Chem-Safe Inc. CC
Environmental Engineering ft Testing CC
Faytek Incorporated AT,CC
Hazen Research, Inc. CC
Integral Resources, Inc. AT
Madrona Divirsified, Inc. CC
Radon Screening Service, Inc. AT,CC
Radon Testing Svc, Englewood, CO CC,GW
Scientific Analysis, Inc. CC
Sorensen Enterprises, Inc. CC
West Coast Environmental Services CC
NEW HAMPSHIRE
AAAirscan Engineering Corp. AT,CC
AIDCO Maine Corp CC
Boxford Radon Lab (B.R.L.) CC
Cavin Analytical Consultants CC,GR,GW
Chem-Safe Inc. CC
Commonwealth Eng. ft Technology CC
Environmental Control Technologies CW
Environmental Sys. Service Ltd CC
Environmental Systems Service CC
Federal Nuclide Monitors CC
Microbac Labs, Erie Testing Lab Div CC
Microbac Labs, Hanover, PA CC
* Company
Measurement Methods
Microbac Labs, MA Testing Division
Microbac Labs, New Castle, PA
Microbac Labs, Pittsburgh, PA
Microbac Labs, Schiller Div.
Microbac Labs, Seaway Div
New England Radon, LTD.
Radon Detection, Inc.
Radon Inspection Service
Radon Registry
Radon X Company, Inc., The
Radonics, Inc.
Residential Radon Test Service
Scientific Analysis, Inc.
Sorensen Enterprises, Inc.
NEW JERSEY
A-l Sherlock Home Inspectors
AAAirscan Engineering Corp.
ABE Radiation Measurements Lab
AIDCO Maine Corp
Air-N-Sol Corporation
A11 Eastern Home Inspection Co.
BCT
Biomedical Toxicology Assoc.
CDS Technologies, Inc.
Cavin Analytical Consultants
Chem-Safe Inc.
Chief Construction Specialists
Commonwealth Eng. ft Technology
Continental Environment Company
Dittmar Inspection Co. Inc.
ECO Testing Corporation
Eastern Integrated Services
Ecological Interactions, Inc.
Environmental Engineering ft Testing
Environmental Radioactivity Measure
Environmental Sys. Service Ltd
Environmental Systems Service
Enviroserv
CC
CC
CC
CC
CC
CC
CR
GW
CC
GW
GW,CW
CC
CC
CC
CW
AT,CC
GR,GW,CW
CC
AT
CC
CC
CC
CW
CC,GR,GW
CC
CC
CC
AT,CC
CC
CC
CC
AT,CC
CC
CR,GR
CC
CC
CW
* For addresses, phone numbers, and performance records see Table 2*
+ Non-conmercial laboratory for research purposes or State agencies' assistance only.
-------
TABLE 1
MEASUREMENT COMPANIES BY SERVICE AREAS
* Company
Measurement Methods
* Company
Measurement Methods
Envr. Testing & Consulting Corp. CC,CW
Excel Inspection Service Inc. CC
,Faytek Incorporated AT,CC
:Federal NucIide Monitors CC
Foresight Engineering, Inc., NJ CC,CW
Garco Research Company CC
Health Physics Associates, Inc. GR,GW,CW
Home-Tech Engineering CC
JBK Inspection Service, Inc. CC
Lamson Home Inspections CC
MRC Home Inspections CC
Microbae Labs, Erie Testing Lab Div CC
Microbac Labs, Hanover, PA CC
Microbac Labs, MA Testing Division CC
Microbac Labs, New Castle, PA CC
Microbac Labs, Pittsburgh, PA CC
Microbac Labs, Schiller Div. CC
Microbac Labs, Seaway Div CC
+ NJ DEP - Bureau of Env. Radiation CC,OW,CW
» NJ Dept of Environmental Protection CC
0. K. Rems Corp. GW
Princeton Home Inspection Svc. CC
R.J. Moore t Associates, Inc. AT,CC
Radiation Surveys Incorporated CC,GR
Radon detection Services, Inc., NJ GW,CW
Radon Diagnostics CC
Radon Engr, a Unit of PSI Engr, Inc CW
Radon Gasbusters CW
Radon Inspection Service AT,CC,CR,GR,GW
Radon Management Laboratories CC,GW,RP
Radon Mitigators, Inc. CC
Radon Safety Services, Inc. CW
Radon Technologies Inc. AT,CC,GR
Radon Testing Svcs, Princeton, NJ CC
Radonics, Inc. GW,CW
Ram Exterminators CC
Ross Systems, Inc. GW,CW
Safe & Sound Home Inspect. Con CC
Safe Shelter Environmental CW
Scientific Analysis, Inc. CC
Shelterworks Inc.
Shotwell Associates
Silver Springs Home Inspection
Sorensen Enterprises, Inc.
Thorough Check, Inc.
CC
GW,CW
GW
CC
CC
U.S. Toxic Substance Testing Bureau CW
Union Cnty. Bid. Inspection Svc CC
NEW MEXICO
Alpha Radon Screening & Home
Cavin Analytical Consultants
Chem-Safe Inc.
Hazen Research, Inc.
Integral Resources, Inc.
Madrona Divirsifled, Inc.
Natural Resource Technologies
Radon Measurement and Control
Radon Screening Service, Inc.
Radon Testing Svc, Englewood, CO
Scientific Analysis, Inc.
Sorensen Enterprises, Inc.
NEW YORK
A-l Sherlock Home Inspectors
AMirscan Engineering Corp.
ABE Radiation Measurements Lab
AIDCO Maine Corp
Air-N-Sol Corporation
All Eastern Home Inspection Co.
Biomedical Toxicology Assoc.
Boxford Radon Lab (B.R.L.)
CDS Technologies, Inc.
Cavin Analytical Consultants
Chem-Safe Inc.
Chief Construction Specialists
Commonwealth Eng. ft Technology
Continental Environment Company
ECO Testing Corporation
CC
CC,GR,GW
CC
CC
AT
CC
CC
AT
AT,CC
CC,GW
CC
CC
CW
AT,CC
GR,GW,CW
CC
AT
CC
CC
CC
CW
CC,GR,GW
CC
CC
CC
AT,CC
CC
* For addresses, phone numbers, and performance records see Table 2.
+ Non-commercial laboratory for research purposes or State agencies' assistance only.
-------
TABLE 1
MEASUREMENT COMPANIES BY SERVICE AREAS
00
Company
Measurement Methods
Ecological Interactions, Inc.
Environmental Radioactivity Measure
Environmental Sys. Service Ltd
Environmental Systems Service
Enviroserv
Faytek Incorporated
Federal NucIide Monitors
Garco Research Company
Health Physics Associates, Inc.
Home-Tech Engineering
MRC Home Inspections
Microbac Labs, Erie Testing Lab Div
Microbac Labs, Hanover, PA
Microbac Labs, MA Testing Division
Microbac Labs, New Castle, PA
Microbac Labs, Pittsburgh, PA
Microbac Labs, Schiller Div.
Microbac Labs, Seaway Div
+ New York State Dept. of Health
0. K. Rents Corp.
Radiation Safety Associates, Inc.
Radiation Surveys Incorporated
Radon Detection Services, Inc., NJ
Radon Diagnostics
Radon Engr, a Unit of PSI Engr, Inc
Radon Inspection Service
Radon Management Laboratories
Radon Measurement ft Control
Radon Mitigators, Inc.
Radon Safety Services, Inc.
Radon Technologies Inc.
Radon X Company, Inc., The
Radonics, Inc.
Res-I-Tec
Ronald Stein Construction Inc.
Ross Systems, Inc.
Scientific Analysis, Inc.
Shotwell Associates
Sorensen Enterprises, Inc.
AT,CC
CR,GR
CC
CC
cw
AT,CC
CC
CC
GR,GW,CW
CC
CC
CC
CC
CC
CC
CC
CC
CC
CC
GW
CC
CC,GR
GW,CW
CC
CW
AT,CC,CR,GR,GW
CC,GW,RP
CC
CC
CW
AT,CC,GR
GW
GW,CW
CC
AT,CC
GW,CW
CC
GW,CW
CC
* Company
Measurement Methods
NORTH CAROLINA
AAAirscan Engineering Corp. AT
AIDCO Maine Corp CC
Appalachian Envir. Testing Inc CW
Carolina Radon Consultants CC
Cavin Analytical Consultants CC,GR,GW
Chem-Safe Inc. CC
Commonwealth Eng. ft Technology CC
Enviradon, Inc. ^7 CC
Environmental Radon Measurements AT
Environmental Sys. Service Ltd CC
Environmental Systems Service CC
Microbac Labs, Erie Testing Lab Div CC
Microbac Labs, Hanover, PA
Microbac Labs, MA Testing Division
Microbac Labs, New Castle, PA
Microbac Labs, Pittsburgh, PA
Microbac Labs, Schiller Div.
Microbac Labs, Seaway Div
+ NC Dept. of Human Resources
Radiological Physics Services
Radon Management Company
Radonics, Inc.
Roberts Environmental Services
Scientific Analysis, Inc.
Sorensen Enterprises, Inc.
+ University of North Carolina
CC
CC
CC
CC
CC
CC
GR
CC
CC
GW,CW
AT,CC,CR,GR,GW,CW
CC
CC
CC
NORTH DAKOTA
Cavin Analytical Consultants CC,GR,GW
Chem-Safe Inc. CC
Radon Consultants, CO AT,CC
Radon Screening Service, Inc. AT,CC
Radon Testing Svc, Englewood, CO CC,GW
Scientific Analysis, Inc. CC
Sorensen Enterprises, Inc. CC
West Coast Environmental Services CC
* For addresses, phone numbers, and performance records see Table 2.
+ Non-commercial laboratory for research purposes or State agencies' assistance only.
-------
TABLE 1
MEASUREMENT COMPANIES BY SERVICE AREAS
* Company Measurement Methods
OHIO
OH
AIDCO Maine Corp
Cavin Analytical Consultants
Chem-Safe Inc.
Commonwealth Eng. ft Technology
Environmental Sys. Service Ltd
Environmental Systems Service
Enviroserv-Radon Detect, of OH
Hoosier Environmental
Insul-Tech, Inc.
Microbac Labs, Erie Testing Lab Div
Microbac Labs, Hanover, PA
Microbac Labs, MA Testing Division
Microbac Labs, New Castle, PA
Microbac Labs, Pittsburgh, PA
Microbac Labs, Schiller Div.
Microbac Labs, Seaway Div
RADON SURVEY SYSTEMS, Inc.
Radon Detection Systems Inc
Radon Measurement ft Control
Radonics, Inc.
Scientific Analysis, Inc.
Sorensen Enterprises, Inc.
Triple Seal, Inc.
OKLAHOMA
Cavin Analytical Consultants
Chem-Safe Inc.
Columbia Radiological Test Lab
Radon ft Environ. Professionals
Radon Screening Service, Inc.
Radon Testing Svc, Englewood, CO
Scientific Analysis, Inc.
Sorensen Enterprises, Inc.
OREGON
Chem-Safe Inc.
CC
CC,GR,GW
CC
CC
CC
CC
CC
CC
CC
CC
CC
CC
CC
CC
CC
CC
AT.CC
CC
CC
GW,CW
CC
CC
CC
CC,GR,GW
CC
AT
AT,CC
AT.CC
CC.GW
CC
CC
CC
Company
Measurement Methods
Environmental Engineering ft Testing CC
Faytek Incorporated AT,CC
Madron* Diversified, Inc. CC
Radon Testing Svc, Englewood, CO CC.GW
Scientific Analysis, Inc. CC
Sorensen Enterprises, Inc. CC
West Coast Environmental Services CC
PENNSYLVANIA
A-1 Sherlock Home Inspectors CW
AAAirscan Engineering Corp. AT,CC
ABE Radiation Measurements Lab GR,GW,CW
AIDCO Maine Corp CC
Air-N-Sol Corporation AT
All Eastern Home Inspection Co. CC
Alpha-Ban AT,CC
Biomedical Toxicology Assoc. CC
CDS Technologies, Inc. CW
Cavin Analytical Consultants CC,GR,GW
Chem-Safe Inc. CC
Chief Construction Specialists CC
Commonwealth Eng. ft Technology CC
Continental Environment Company AT,CC
Ecological Interactions, Inc. ' AT,CC
Environmental Sys. Service Ltd CC
Environmental Systems Service CC
Enviroserv CW
Enviroserv-Radon Detect, of OH CC
Faytek Incorporated AT,CC
Foresight Engineering, Inc., NJ CC
Garco Research Company CC
Health Physics Associates, Inc. GR,GW,CW
Home-Tech Engineering CC
Insul-Tech, Inc. CC
Microbac Labs, Erie Testing Lab Div CC
Microbac Labs, Hanover, PA CC
Microbac Labs, MA Testing Division CC
Microbac Labs, New Castle, PA CC
Microbac Labs, Pittsburgh, PA CC
..* For addresses, phone numbers, and performance records see Table 2.
+ Non-commercial laboratory for research purposes or State agencies' assistance only.
-------
TABLE 1
MEASUREMENT COMPANIES BY SERVICE AREAS
Company
Measurement Methods
* Company
Measurement Methods
ro
o
Microbac Labs, SchiI lor Div. CC
Microbac Labs, Seaway Div CC
0. K. Rems Corp. GW
Princeton Home Inspection Svc. CC
R.J. Moore ft Associates, Inc. AT,CC
Radioactivity Alert Detection Serv. AT,CC
Radon Detection Services, Inc., NJ GW,CW
Radon Diagnostics CC
Radon Inspection Service AT,CC,CR,GR,GW
Radon Management Company CC
Radon Management Laboratories CC,GW,RP
Radon Mitigators, Inc. CC
Radon Safety Services, Inc. CW
Radon Technologies Inc. AT,.CC,GR
Radon Testing Svcs, Princeton, NJ CC
Radonics, Inc. GW,CW
Reynolds Radiological Services, Inc CW
Ross Systems, Inc. GW,CW
Safe Shelter Environmental CW
Science Management Services, Ltd. GW
Scientific Analysis, Inc. CC
ShotwelI Associates GW,CW
Soronsen Enterprises, Inc. CC
U.S. Toxic Substance Testing Bureau CW
RHODE ISLAND
AAAirscan Engineering Corp. AT,CC
AIDCO Maine Corp CC
Biomedical Toxicology Assoc. CC
Boxford Radon Lab (B.R.L.) CC
Cavin Analytical Consultants CC,GRJGW
Commonwealth Eng. ft Technology CC
Environmental Control Technologies CW
Environmental Sys. Service Ltd CC
Environmental Systems Service CC
Env i roserv CW
Foresight Engineering, Inc., VA CC
Microbac Labs, Erie Testing Lab Div CC
Microbac Labs, Hanover, PA CC
Microbac Labs, MA Testing Division CC
Microbac Labs, New Castle, PA CC
Microbac Labs, Pittsburgh, PA CC
Microbac Labs, Schiller Div. CC
Microbac Labs, Seaway Div CC
New England Radon, LTD. CC
Radiation Safety Associates, Inc. CC
Radon Engr, a Unit of PSI Engr, Inc CW
Radon Inspection Service GR,GW
Radonics, Inc. GW,CW
Residential Radon Test Service CC
Scientific Analysis, Inc. CC
Sorensen Enterprises, Inc. CC
SOUTH CAROLINA
AAAirscan Engineering Corp. ' AT,CC
Carolina Radon Consultants CC
Cavin Analytical Consultants CC,GR,GW
Commonwealth Eng. ft Technology CC
Enviradon, Inc. KJ (£
Environmental Radon Measurements AT
Environmental Sys. Service Ltd CC
Environmental Systems Service CC
Enviroserv-Radon Detect, of AL CC
Microbac Labs, Erie Testing Lab Div CC
Microbac Labs, Hanover, PA CC
Microbac Labs, MA Testing Division CC
Microbac Labs, New Castle, PA CC
Microbac Labs, Pittsburgh, PA CC
Microbac Labs, Schiller Div. CC
Microbac Labs, Seaway Div CC
+ S. C. Dept of Health ft Env Control CC
Scientific Analysis, Inc. CC
Sorensen Enterprises, Inc. CC
SOUTH DAKOTA
Cavin Analytical Consultants CC,GR,GW
Chem-Safe Inc. £C
* For addresses, phone numbers, and performance records see Table 2.
+ Non-commercial laboratory for research purposes or State agencies' assistance only.
-------
ro
Company
TABLE 1
MEASUREMENT COMPANIES BY SERVICE AREAS
Measurement Methods * Company
Measurement Methods
Energy Marketing Midwest, Inc
Radon Consultants, CO
Radon Screening Service, Inc.
Radon Testing Svc, Englewood, CO
Scientific Analysis, Inc.
Sorensen Enterprises, Inc.
West Coast Environmental Services
TENNESSEE
CC
AT,CC
AT,CC
CC,GW
CC
CC
CC
ACI Chemical Co. In, d/b/a ACI Insu
AIDCO Maine Corp
Advanced Materials Enterprises, Inc
CDS Technologies, Inc.
Carolina Radon Consultants
Cavin Analytical Consultants
Chem-Safe Inc.
Commonwealth Eng. & Technology
Energy Systems, Inc
Environmental Radon Measurements
Environmental Sys. Service Ltd
Environmental Systems Service
Enviroserv-Radon Detect, of AL
Microbac Labs, Erie Testing Lab Div
Microbac Labs, Hanover, PA
Microbac Labs, MA Testing Division
Microbac Labs, New Castle, PA
Microbac Labs, Pittsburgh, PA
Microbac Labs, Schiller Div.
Microbac Labs, Seaway Div
Radiation Services Inc.
Radon Air Pollution Testing Co, Inc
Radon Detection Systems of TN
Radon Measurement & Control
Safe Air
Scientific Analysis, Inc.
Sorensen Enterprises, Inc.
TEXAS
CC
CC
CC
CW
CC
CC,GR,GW
CC
CC
AT,CC,CR,GR
AT
CC
CC
CC
CC
CC
CC
CC
CC
CC
CC
GR.
AT,CC
CC,GW
CC
CC
CC
CC
Cavin Analytical Consultants CC,GR,GW
Chem-Safe Inc. °C
Continental Environment Company AT,CC
Environmental Engineering ft Testing CC
Madrona Divirsified, Inc. CC
Radon Measurement and Control AT
Radon Testing Svc, Englewood, CO CC,GW
Scientific Analysis, Inc.
Sorensen Enterprises, Inc.
West Coast Environmental Services
CC
CC
CC
UTAH
Cavin Analytical Consultants
Chem-Safe Inc.
Environmental Engineering & Testing
Faytek Incorporated
Hazen Research, Inc.
Integral Resources, Inc.
Madrona Divirsified, Inc.
Radiation Surveys Incorporated
Radon Consultants, CO
Radon Measurement and Control
Radon Screening Service, Inc.
Radon Testing Svc,.Englewood, CO
Scientific Analysis, Inc.
Sorensen Enterprises, Inc.
West Coast Environmental Services
VERMONT
AAAirscan Engineering Corp.
AIDCO Maine Corp
Biomedical Toxicology Assoc.
Boxford Radon Lab (B.R.L.)
Cavin Analytical Consultants
Commonwealth Eng. ft Technology
Environmental Control Technologies
Environmental Sys. Service Ltd
Environmental Systems Service
CC,GR,GW
CC
CC
AT.CC
CC
AT
CC
CC,GR
AT.CC
AT
AT,CC
CC,GW
CC
CC
CC
AT,CC
CC
CC
CC
CC,GR,GW
CC
CW
CC
CC
* For addresses, phone numbers, and performance records see Table 2.
+ Non-conroercial laboratory for research purposes or State agenc.es' assistance only.
-------
TABLE 1
MEASUREMENT COMPANIES BY SERVICE AREAS
ro
IV3
Company
Measurement Methods
Microbac Labs, Erie Testing Lab Div CC
Microbac Labs, Hanover, PA CC
Microbsc Labs, MA Testing Division CC
Microbac Labs, New Castle, PA CC
Microbac Labs, Pittsburgh, PA CC
Microbac Labs, Schiller Div. CC
Microbac Labs, Seaway Div CC
New England Radon, LTD. CC
Radon Detection, Inc. CR
Radon Engr, a Unit of PSI Engr, Inc CW
* Company
Measurement Methods
Radon Inspection Service
Radon Registry
Radon Technologies Inc.
Radon X Company, Inc., The
Residential Radon Test Service
Scientific Analysis, Inc.
Sorensen Enterprises, Inc.
VIRGINIA
AAAirscan Engineering Corp.
AIDCO Maine Corp
Abionics, Ltd.
Alpha Control, Inc.
Appalachian Envir. Testing Inc
Biomedical Toxicology Assoc.
rCavin Analytical Consultants
,Chem-Safe Inc.
Commonwealth Eng. & Technology
Continental Environment Company
Environmental Engineering & Testing
Environmental Radon Measurements
Environmental Sys. Service Ltd
Environmental Systems Service
Enviroserv
Federal Nuclide Monitors
Foresight Engineering, Inc., NJ
foresight Engineering, Inc., VA
Garco Research Company
Home Sure Inspections, Inc.
GR GW
cc
AT CC GR
GW
CC
CC
CC
AT,CC
CC
AT,CC
GW
CW
CC
CC,GR,GW
CC
CC
AT,CC
CC
AT
CC
CC
CW
CC
CC,CW
CC
CC
GR
Microbac Labs, Erie Testing Lab Div CC
Microbac Labs, Hanover, PA CC
Microbac Labs, MA Testing Division CC
Microbac Labs, New Castle, PA CC
Microbac Labs, Pittsburgh, PA CC
Microbac Labs, Schiller Div. CC
Microbac Labs, Seaway Div CC
R.J. Moore & Associates, Inc. AT,CC
RADON Home Inspection Service GW
Radiological Physics Services CC
Radon Engr, a Unit of PSI Engr, Inc CW
Radon Management Company CC
Radonics, Inc. QW CW
Scientific Analysis, Inc. CC*
Sorensen Enterprises, Inc. CC
Terradynamics Corporation AT
WASHINGTON
Cavalier Corporation CC
Chem-Safe Inc. CC
Faytek Incorporated AT cc
Insul-Tech, Inc. cc
Madrona Divirsified, Inc. CC
+ Nuclear Radiation Center CC
Radon Testing Svc, Englewood, CO CC,GW
Scientific Analysis, Inc. CC
Sorensen Enterprises, Inc. CC
West Coast Environmental Services CC
WEST VIRGINIA
AAAirscan Engineering Corp. AT CC
AIDCO Maine Corp cc'
Cavin Analytical Consultants CC,GR,GW
Commonwealth Eng. & Technology CC
Environmental Sys. Service Ltd CC
Environmental Systems Service CC
Env i roserv CW
Foresight Engineering, Inc., VA CC
* For addresses, phone numbers, and performance records see Table 2
* Non-commercial laboratory for research purposes or State agencies' assistance only.
-------
ro
OJ
TABLE 1
MEASUREMENT COMPANIES BY SERVICE AREAS
Company
Measurement Methods
* Company
Measurement Methods
Microbac Labs, Erie Testing Lab Div
Microbac Labs, Hanover, PA
Microbac Labs, MA Testing Division
Microbac Labs, New Castle, PA
Microbac Labs, Pittsburgh, PA
Microbac Labs, Schiller Div.
Microbac Labs, Seaway Div
Radiological Physics Services
Radon Engr, a Unit of PSI Engr, Inc
Radon Management Company
Radon Measurement & Control
Radon ics, Inc.
Scientific Analysis, Inc.
Sorensen Enterprises, Inc.
WISCONSIN
CC
CC
CC
CC
CC
CC
CC
CC
cw
CC
CC
GW,CW
CC
CC
Scientific Analysis, Inc. CC
Sorensen Enterprises, Inc. CC
West Coast Environmental Services CC
PUERTO RICO
Cavin Analytical Consultants CC,GR,GW
New England Radon, LTD. CC
Sorensen Enterprises, Inc. CC
VIRGIN ISLANDS
AAAirscan Engineering Corp. AT,CC
Cavin Analytical Consultants CC,GR,GW
Sorensen Enterprises, Inc. CC
CC
CC
CC
Cavin Analytical Consultants CC,GR,GW
Chem-Safe Inc.
Enviroserv-Radon Detect, of OH
Home Buyers Inspection Service
Radon Detection Specialists
Radon Surveys, Div. Alpha Tech Corp GW
Scientific Analysis, Inc. CC
Sorensen Enterprises, Inc. CC
WYOMING
Alpha Radon Screening & Home CC
Cavin Analytical Consultants CC,GR,GW
Chem-Safe Inc. CC
Colorado Radon Engineering Inc CC
Environmental Engineering ft Testing CC
Faytek Incorporated
Hazen Research, Inc.
Integral Resources, Inc.
Natural Resource Technologies
Radon Consultants, CO
Radon Screening Service, Inc.
Radon Testing Svc, Englewood, CO
AT,CC
CC
AT
CC
AT,CC
AT,CC
CC.GW
For addresses, phone numbers, and performance records see Table 2.
Non-commercial laboratory for research purposes or State agencies' assistance only.
-------
TABLE 2
PERFORMANCE RESULTS OF COMPANIES
* Company
A-l Sherlock Home Inspectors
6-O1 Fair lawn Avenue,
Fair lawn, NJ 07410
Steven J. Luxton
(201) 796-4942
AAAirscan Engineering Corp.
8 Eric Drive
Granby, CT 06035
Kevin O'Rourke
(203) 653-5639 (203) 653-4787
ABE Radiation Measurements Lab
Box 214
Lenhartsvi lie, PA 19534
r\)
-P1 Anthony LaMastra
(215) 756-4153
ABMS, Inc.
5506 San Pablo Ave
Oakland, CA 94608
Tim Hussler
(415) 547-7144
ACI Chemical Co. In. d/b/a ACI Insu
P. 0. Box 306
Walnut Ridge, AR 72476
Charles E. Snapp
(501) 886-6625
AIDCO Maine Corp
Grassy Pond House
Rindge, NH 03461
Robert K. Multer
(603) 899-5166
»«^> v, lYUQon nor* ing Level n»fj» «f &,* w < i
Round Measurement Measurement QA D±njf ^'f" f *£klnfl Uv?'
AT rr rp t>a rvi DO /- o? Wound Measurement Measurement QA
AT CC CR « GW RP CW Plan * Company AT CC CR GR GW RP CW Plan
5/87 il ARIX Sciences, Inc. 5/87 Ll Ll
1200 E. High St.
Pottstown, PA 19464
WilliamF. McKelvey
(215) 327-1140
»/»? LJ L1 Abionics, Ltd. n/88 Ll Ll
5/87 Ll Ll 12509 Kings Lake Dr. 5/87 Ll Ll
Reston, VA 22091 - ..
Dr. William R. Hancuff
(703) 620-3787
6/87 Ll Ll Ll Li X Accu-Test 5/37 Ll Ll
Suite 115-343, 1350 Beverly Rd
McLean, VA 22101
Bruce Johnson
(703) 448-8088
5'87 1=1 Accurate Air Testing 11/88 Ll
1209 Piney Woods Drive 5/87 Ll
Friendswood, TX 77546
Charles T. Gallagher
(713) 482-5097
5/87 L1 Advanced Materials Enterprises, Inc 5/87 Ll
P. 0. Box 121174
Nashville, TN 37212
Ron Queries
(615) 377-0624
E/87 L1 * Advanced Radiation Monitoring Serv. 5/87 Ll
2219 Prosperity
Portage, MI 49081
Philip B. Noack
(616) 323-9483
». JM«a^», ^^^^«^^^^__ - 1-1,1 »! u_l_
* See TABLE 1 for the States each company serves
Note:
capabl- of
See Definitions of Performance Indicators on pages 5 and 6.
-------
TABLE 2
PERFORMANCE RESULTS OF COMPANIES
* Company
Date of .Radon
Round Measurement
AT £C CR CR
Working Level
Measurement QA
GW ,tf> CW Plan
* Company
Date of Radon
Round Measurement
AT CC CR GR
Working Level
Measurement QA
GW RP CW Plan
Affiliated Building Inspectors, Inc 5/87 LI LI
7223 Delfield Street .
Chevy Chase, MD 20815
Larry Wasson
(301) 986-8866
Air Chek, Inc.
Box 2000
Arden, NC 28704
B. V. Alvarez
(704) 684-O893
Air Sciences, Inc/Overman Assoc.
P.O. Box 376
Bonne Terre, MO 63628
en Ralph T. Overman, Ph.D.
(314) 358-4011
Air-N-Sol Corporation
P.O. Box 437
Frenchtown, NJ 08826
Dale L. Johnson
(201) 996-2028
Air-Tight of Genesee
2429 N. Dort Hwy
t Flint, MI 48506
David Neb lock
(313) 235-5010
All Eastern Home Inspection Co. 6/87
309 Bloomfield Ave
Caldwell, NJ 07006
Peter Kras / Wi11iam Rodgers
, (201) 228-5548
4/86
7/86
11/86
5/87
A/86
7/86
11/86
5/87
4/86 LI
7/86 LA
11/86 LI
6/87 LI
5/87
LI
LI
LI
LI
LI
U.
LI
LI
LI
LI
LI
LI
LA
LI
LI
LI
LI
AIpha ControI, Inc.
6407 Good Luck Road
Riverdale, MD 20737
Scott Parry
(301) 474-0071
Alpha Radon Screening & Home
Inspection Inc.
1216 Chinook Way
Boulder, CO 8O303
Bill Jewell
(303) 494-9533
Alpha Spectra
P. 0. Box 6772
Denver, CO 80206
Frank Wilkinson III, M. S.
(303) 377-2118
AIpha-Ban
5330 Long Corner Road
White Hall, MD 21161
Kirk Nevin
(301) 692-2700
Amersham Corporation
2636 South Clearbrook Drive
Arlington Heights, IL 60005
Mark A. Doruff
(316) 693-6300
Appalachian Envir. Testing Inc
105 South Union St. Suite 326
Danville, VA 24641
Christopher R. Halladay
(804) 792-1300
11/86
5/87
5/87
LI
LI LI
LI
LI
Li
5/87 LI
11/86 LI
6/87 LI LI
7/86 LI
11/86 LI
6/87 LI LA
7/86 LI
11/86 "LI
5/87 LI
DT
LI
LI
* See TABLE 1 for the States each company serves.
Note: Underscored performance indicators denote a primary company capable of performing measurement analyses in house or making measurements
using operators and instruments belonging to the company.
See Definitions of Performance Indicators on pages 5 and 6.
-------
TABLE 2
PERFORMANCE RESULTS OF COMPANIES
* Company
Date of Radon
Round Measurement
AT CC CR GR
Working Level
Measurement Q.A
GW RP CW Plan
Company
Date of Radon
Round Measurement
AT CC CR GR
Working Level
Measurement QA
GW RP CW Plan
Applied Energy Company
3316 Augusta Avenue
Omaha, NE 68144
Jon Traudt
(402) 334-5881
Applied Health Physics Inc.
2986 Industrial Boulevard
Box 197
Bethel Park, PA 15102
Nathaniel L. Burden, Jr.
(412) 563-2242
Applied Radon Test. & Reduct'n
52205 Warehime Rd.
Cumberland, OH 43732-9804
Cft Frank J. Donia
(614) 638-2078
Argonne National Laboratory
9700 South Cass Avenue
Argonne, IL 60439
Henry Lucas
(312) 972-4172
BCT
12 Magnolia Ave.
Danville, NJ 07834
Kevin Scot tans
(201) 627-2802
Barcon, Inc.
599 Waldron Road
LaVergne, TN 37086
Randal I G. Smith
(615) 793-7993
5/87 LI
11/86 LI LI LI LI
5/87 LI LI LI LI LA
5/87 LI
LI
5/87
LI
11/86 LI
5/87 LA
5/87 LI LI
Barringer Laboratories, Inc.
15000 West Sixth Avenue,Suite 300
Golden, CO 80401
David Lasher
(303) 277-1687
Battelle
505 King Avenue
Columbus, OH 43201
V. Pasupathi
(614) 879-5163
Biomedical Toxicology Assoc.
P. 0. Box 3568
Frederick, MD 21701
Winifred G. Palmer, Ph.D.
(301) 662-0783
Bowling Green Radon Laboratory
P. 0. Box 83
Bowling Green, KY 42101
David W. Williams
(502) 842-6200
7/88
11/88
5/87
11/86
5/87
7/86
11/86
5/87
LI
LI
LI
LI
LI LI LI
LI
LI
LI
5/87 LI
Boxford Radon Lab
52 WiIdmeadow Rd
Boxford, MA 01921
(B.R.L.)
5/87 LI
John Fisher
(617) 887-9641
CA State Dept. of Health Serv.
Sanitation and Radiation Lab
2151 Berkeley Way, Room 465
Berkeley, CA 94704
George S. Uyesugi
(415) 540-2201 (415) 540-2515
6/87
LI
LI
* See TABLE 1 for the States each company serves.
Note: Underscored performance indicators denote a primary company capable of performing measurement analyses in house or making measurements
using operators and instruments belonging to the company.
See Definitions of Performance Indicators on pages 5 and 6.
-------
TABLE 2
PERFORMANCE RESULTS OF COMPANIES
* Company
Date of Radon
Round Measurement
AT CC CR GR'
Working Level
Measurement QA
GW RP CW Plan
CDS Technologies, Inc.
5050 Ti Ighman Street
A 1 1 en town, PA 18104
Richard D. Martin
(215) 398-7125
CMT Inc.
2813 Rio Vista
Emporia, KS 66801
Michael M. Nichols
(316) 342-2760
Camp Dresser ft McKee Inc.
Raritan Plaza 1, Raritan Ctr.
Edison, NJ 08818
£!- Jay W. Davis
(201) 225-7000
Camroden Associates
RD #4 Box 62
Rome, NY 13440
Terry Brennan
(315) 865-4269
Canberra Industries Inc.
One State Street
Meriden, CT 06450
Bruce M. Gi I lespie
(203) 238-2351
Capital Materials Testing Inc.
P. 0. Box 81
Latham, NY 12110
5/87 LI LI
LI
11/86
5/87
5/87
LI
LI
LI LI LI LI
LI X
5/87 LI LI LI LI
6/87 LI
5/87 LI
. Attridge
(518) 783-3150
* Company
Date of Radon
Round Measurement
AT CC CR GR
Working Level
Measurement QA
GW RP CW Plan
Carolina Radon Consultants 5/87 LI
Box 2000
Etowah, NC 28729
Ned Doyle
(704) 891-9559
Cavalier Corporation 5/87 LI
11516 E. Sprague
Spokane, WA 99206
Warren Riddie
(509) 926-6217
Cavin Analytical Consultants
P. 0. Box 454
Snellville, GA 30278
Donald K. Cavin
(800) 533-1224
Centarus Corporation 5/87
P. 0. Box 513
Glasgow, KY 42141
G. Wayne Calvert
(502) 651-2396
Chem-Safe Inc. 5/87
1345 Research ft Technology Pk.
Pullman, WA 99163
Cliff Cooper
(509) 335-O922
Chemical Engineering Unit, RTI 5/87
Research Triangle Institute
P. 0. Box 12194
Research Triangle Park, NC 27709
Linda Michaels / Andy Viner
(919) 541-6261 (919) 541-6747
5/87 LI LI LI
LI
LI
LI
* See TABLE 1 for the States each company serves.
Note: Underscored performance indicators denote a primary company capable of performing measurement analyses in house or making measurements
using operators and instruments belonging to the company.
See Definitions of Performance Indicators on pages 5 and 6.
-------
TA8LE 2
PERFORMANCE RESULTS OF COMPANIES
* Company
Date of Radon
Round Measurement
AT CC CR GR
Working Level
Measurement QA
GW RP CW Plan
Chief Construction Specialists
and Inspectors, Inc.
Box 284
Towaco, NJ 07082
Richard D. Conk I in
(201) 299-9087
Clean Air Engineering, Inc.
207 North Woodwork Lane
Palatine, IL 60067
Ann Marie Ramsden
(312) 991-3300
Colorado Radon Engineering Inc
5104 Greenview Ct.
Ft. Collins, CO 80525
TO Bill Alexander
(303) 223-9755
Columbia Radiological Test Lab
4054 Victoria Court
Columbia, MO 65201
William E. Becker / M Milewski
(314) 443-3538
Commonwealth Eng. £ Technology
3113 North Front Street
Harrisburg, PA 17110
Judy F. Musselman
(717) 232-2288
11/88
5/87
6/87
LI
LI
LI
5/87
LI
6/87 LI
6/87
LI
Con-Test, Inc.
126 Shaker Road
East Longmeadow,
MA 01028
7/86
11/86
5/87
LI
LI
LI
David A. MacLean
(413) 525-1198
* Company
Date of Radon
Round Measurement
AT CC CR GR
Working Level
Measurement QA
GW RP CW Plan
Continental Environment Company
34 Maple Street
Summit, NJ 07901
Alvin M. Natkin
(201) 277-2265
Core Laboratories Inc
420 West First St
Casper, Wy 82601
David L. Demorest
(303) 235-6741
Dittmar Inspection Co. Inc.
20 Redding Place
Towaco, NJ 07082
Willy C. fcittmar
(201) 263-4745
ECO Testing Corporation
RD. 1 Box 266 B
Annandale, NJ 08801
Peter W. Georges
(201) 735-2^70
EKS RadTech
1000 Herald Square
Aston, PA 19014
John T. Hoback
(215) 368-9425 (215) 358-9426
ENV Services, Inc.
216 Goddard Blvd., Suite 117
King of Prussia, PA 19406
Scott Berger
(800) 346-0094 (215) 337-8222
4/86 LI
7/86 LI
11/86 LI LI
6/87 LI LI
5/87
LI
5/87
LI
6/87
LI
5/87
LI
5/87
LI
* See TABLE 1 for the States each company serves.
Note: Underscored performance indicators denote a primary company capable of performing measurement analyses in house or making measurements
using operators and instruments belonging to the company.
See Definitions of Performance Indicators on pages 5 and 6.
-------
_ TABLE 2;
PERFORMANCE RESULTS OF COMPANIES
* Company
Date of Radon
Round Measurement
AT CC CR GR
Working Level
Measurement QA
GW RP CW Plan
* Company
Date of Radon Working Level
Round Measurement Measurement QA
AT CC CR GR GW RP CW Plan
Eastern Integrated Services
P. 0. Box 784
Princeton Jet., NJ 08550
Bi11 Thompson / Rick Pettit
(609) 799-8574
Eberline Instrument Corp.
P. 0. Box 2108
Santa Fe, MM 87504-2108
Eric L. Geiger
(505) 471-3232
Ecological Interactions, Inc.
96 East Main Street
Rockaway, NJ 07866
£; F. Michael Fitzpatrick
(201) 625-7700
Electro Mechanical Concepts
130 Mountaineer Lane
West Miff I in, PA 15122
Matt Kovac
(412) 276-2272
EnRad, Inc./Rad. T. & Eng. Inc
18705 B. North Frederick Road
Gaithersburg, MD 20879
Charles Osterberg, Ph.D.
(301) 948-8040
Energy Marketing Midwest, Inc
E-S7 Rd, Box 93
Kelley, IA 50134
Kenneth D. Wiggers
(515) 769-2400
5/87
LI
4/88
7/86
11/86
5/87
11/86 LI LI
5/87 LI LI
Li
LI LI X
ML LI
il LI
LI LI
4/86
7/86
11/86
5/87
LI
LI
LI
LI
7/86 LI
11/86 U
5/87 LI LI
5/87
LI
Energy Systems, Inc
134 Carr avenue
Cookeville, TN 38501
Dwight G Moore, Jr
(615) 628-7247
Enviradon, Inc.
914 Rollingwood Drive
Mt. Holly, NC 28120
William Brad McRee
(704) 827-1293
Envirohazards Management, Inc.
P. 0. Box 1064
So. Orange, NJ 07079
Diane Trainor
(201) 761-7226
Environ. Detection Associates
P. 0. Box 1008
Pisgah Forest, NC 28768-1006
Wolfgang Selle or Harry Hi 11
(704) 877-4300
Environmental Chemistry
1233 Ogden Street, Suite 604
Denver, Colorado 80218
John B. Taylor
(303) 831-0437
Environmental Control Technologies
400 Amherst Street
Nashua, NH 03063
Harold W. Eriksen
(603) 881-7133
5/87 LI LI LI LI
7/88
11/86
5/87
5/87
LI
LI LI
LI LI
LI
6/87
LI
5/87
LI
5/87
LI
* See TABLE 1 for the States each company serves.
Note: Underscored performance indicators denote a primary company capable of performing measurement analyses in house or making measurements
using operators and instruments belonging to the company.
See Definitions of Performance Indicators on pages 6 and 6.
-------
TABLE 2
PERFORMANCE RESULTS OF COMPANIES
Date of Radon
Round Measurement
AT CC CR GR
Company
Environmental Engineering ft Testing 11/86 LI
9185 East Kenyon Ave., Suit* 19O 5/87 LA
Denver, CO 80237
G. P. Logan
. (303) 722-2112
Environmental Radioactivity Measure 7/86 LI LI
P. 0. Box 226 11/86 LI LI
Piermont, NY 10968 5/87 LI LI
Katherine El I ins
(914) 353-3513, (914) 3S3-O208
Environmental Radon Measurements 5/87 LI
49 N. Orange Ave.
Orlando, PL 32801
o Catherine Hershey
(305) 648-1969
Environmental Risk Consultants, Inc 5/87 LI
800 Cluster
Evanston, IL 60202
David Slutzky
(312) 864-1265
Environmental Sys. Service Ltd 5/87 LI
P. 0. Box'220
College Park, MD 2O740
G. D. Fleming
(301) 779-0606
Environmental Systems Service 5/87 LI
P. 0. Box 512
Culpeper, VA 22701
Cheryl B. Ludy
(703) 825-6660
Working Level
Measurement QA
GW RP CW Plan
LI
* Company
Date of Radon
Round Measurement
AT CC CR GR
Working Level
Measurement QA
GW RP CW Plan
Env i roserv
15 Buckley Hill Road
Morristown, NJ 07960
Donald M. Ulbrich
(2010 285-1065
Enviroserv-Radon Detect, of AL
325-D Poplar Place
Birmingham, AL 35209
Douglas T. Ulbrich
(205) 871-6715
Enviroserv-Radon Detect, of OH
781 Mount Vernon Ave.
Marion, OH 43302
D. Todd Ulbrich
(614) 382-2354
7/86 LI
11/86 LI
5/87 LI
11/86 LI
5/87 LI
Envirotest
P.O. Box 223
North Ridgeville, OH
44039-0223
Vincent A. Gargaro
(216) 327-9432
Envr. Testing ft Consulting Corp.
1316 Gross Street
Manville, NJ 08835
Thomas R. ReiIly
(201) 722-5293
Ero Resources Corporation
2801 Youngfield, Suite #121
Golden, CO 804O1
Mark DeHaven
(303) 231-9022
11/86
5/87
11/86
5/87
4/86
7/88
11/86
5/87
5/87
U
LI
LA
LI
LI
LI
LI
LI
LI
LI
LI
LI
LI
LI
LI
LI
* See TABLE 1 for the States each company serves.
Note: Underscored performance indicators denote a primary company capable of performing measurement analyses in house or making measurements
using operators and instruments belonging to the company.
See Definitions of Performance Indicators on pages 5 and 6.
-------
TABLE 2
PERFORMANCE RESULTS OF COMPANIES
Company
Date of Radon Working Level
Round Measurement Measurement QA
AT CC CR GR GW RP CW Plan
Excel Inspection Service Inc.
438 Windmill Way
Somerville, NJ 08876
Daniel R. Loreti
(201) B26-7277
Faytek Incorporated .
P. 0. Box 2229 ...... .
Coeur D'Alene, ID 83814
Jan Elizabeth Fay
(208) 667-3263
Federal Nuclide Monitors
2023 Park Road, N.W.
Washington, DC 20010
5/87
LI
5/87 LI LI
A. Danckwerth
(202) 265-0429
Foresight Engineering, Inc., NJ
Box 621
Madison, NJ 07940
Theresa Kaufmann
(201) 377-0602
Foresight Engineering, Inc., VA
P. 0. Box 7333
Arlington, VA 22207-0333
Steven Duarte
(703) 525-4790
Frazier Co., The
15105 Industrial Rd.
Omaha, NE 68144
Dean Frazier
(402) 330-3400
11/86
5/87
4/86
7/86
11/86
5/87
E/87
LI
LA
LI
LI
LI
LI
LI
LI
5/87
LI
Company
Date of Radon
Round Measurement
AT CC CR GR
Working Level
Measurement QA
GW RP CW Plan
Futura Medical Systems, Inc. 5/87 LI
387 Regency Ridge
Centerville, OH 45459
E. Theodore Agard, Ph. D.
(513) 436-2215
GEOMET Technologies, Inc.
20251 Century Boulevard
Germantown, MD 2O874
Dr. Niren L. Nagda
(301) 428-9898
4/86 LI
7/86 LI
11/86 LI LI
5/87 LI LA
Garco Research Company 5/87 LI
144A Sutton Road
Lebanon, NJ 08833
Gary J. GiIbert
(201) 832-7895
Garden St. Home Inspection Svc 5/87 LI
475 Valley Rd.
West Orange, NJ O7052
Thomas Pasquariello
(201) 678-3333
General Health Physics Inc. 5/87 U
7217 Lockport PI .
Lorton, VA 22079
John B. Davis
(703) 650-7526
Geo-Chek, Inc. 5/87 LI
2270 Stony Hill Road
Boulder, CO 80303
Phi I Harrington
(303) 494-0576
LI
* See TABLE 1 for the States each company serves. . . .
Note: Underscored performance indicators denote a primary company capable of performing measurement analyses in house or making measurements
using operators and instruments belonging to the company.
See Definitions of Performance Indicators on pages 5 and 6.
-------
TABLE 2
PERFORMANCE RESULTS OF COMPANIES
* Company
Date of Radon
Round Measurement
AT CC CR GR
Working Level
Measurement QA
GW RP CW Plan
* Company
Date of Radon
Round Measurement
AT CC CR GR
Working Level
Measurement QA
GW RP CW Plan
Gesell Institute, The
Env. ft Occupational Health Div
310 Prospect St.
New Haven, CT 06E11
Robert McLellan, MD/MPH
(203) 789-1911
Hazen Research, Inc.
4601 Indiana St.
Golden, CO 80203
5/87 LI LI
5/87 LI
John C. Jarvis
(303) 279-4601 Ex.
218
Health Physics Associates, Inc.
RDI Box 796
Lenhartsvi He, PA 19534
CO
ro
Anthony La Mastra
(215) 756-4153
Health Physics Associates, Ltd.
3304 Commercial Avenue
Northbrook, Illinois 60062
William B. Rivkin
(312) 564-3330
Health and Safety Associates
35 Grove Street
Medford, MA 02155
Neil A. Gaeta
(617) 488-7081
Home Buyers Inspection Service
320 Elmwood Drive
Naperville, IL 60540
John R. Ball P.E.
(312) 357-0903
7/86
11/86
5/87
4/88
7/86
11/86
5/87
LI
LI
LI
LI
LI
LI
LA
LI
LI
LI
LI
LI
LI
LI
5/87 LI LI
6/87
LI
Home Inspection Service, Inc. 5/87 LI
1916 Southland Av«.
Highland Park, IL 60035
Jerry Comer
(312) 432-8861 (312) 831-4545
Home Sentry Inc. 5/87 LI
P. 0. Box 565
Midland Park, NJ O7432
Christopher Pedersen
(201) 662-2497
Home Sure Inspections, Inc. 5/87 LI
444 N. Frederick Ave. STE L348
Gaithersburg, MD 20877
James Scheible
(301) 428-7672
Home Testing Service 5/87 LI
7O Wabasso St.
Waltham, MA 02154
Steven D. Wightman
(617) 862-3440
Home-Tech Engineering 5/87 LI
P. 0. Box 43129
51 Upper Monte lair Plaza
Upper Monte lair, NJ 07O43
David A. Osage
(201) 744-6674
Hoosier Environmental 5/87 LI
11116 Wood Court
Car-met, IN 46032
Richard Jordan
(317) 846-0227
* See TABLE 1 for the States each company serves.
Note: Underscored performance indicators denote a primary company capable of performing measurement analyses in house or making measurements
using operators and instruments belonging to the company.
See Definitions of Performance Indicators on pages 5 and 6.
-------
TABLE 2
PERFORMANCE RESULTS OF COMPANIES
* Company
Date of Radon Working Level
Round Measurement Measurement. QA
AT CC CR GR GW RP CW Plan
* Company
Date of Radon Working Level
Round Measurement : Measurement QA
AT CC CR GR GW RP CW Plan
Hudson Valley Radon Testing Corp.
P.O. Box 790
Poughkeepsie, NY 126O1
Paul Costello, Robert Hare
(914) 431-6424 (914) 485-6561
IL Dept. of Nuclear Safety
1035 Outer Park Drive
Springfield, IL 627O4
Mslanie Anne Hame!
(217) 785-9956
11/86
6/87
LI
LI
7/86 LI
11/86 LI LI
5/87 LI LI
LI
LI
LI
LI
LI
Infiltec
P.O. Box 1533
Falls Church, VA
22041
David W. Saum
(703) 820-7696
Inspex of Boulder, Inc.
2955 Valmont Street, Suite 300
Boulder, CO 80301
Kevin M. O'Hornett
(303) 442-8995
Insul-Tech, Inc.
5559 Wester vi I le Road
Westeville, OH 43081
Danny R. West
(614) 891-9555
Integral Resources, Inc.
1916 East El Parque
Tempe, AZ 85282
Jamas W. Krueger
(602) 967-8O29
7/86
11/86
6/87
5/87
LI
LI
LI
LI
LI
LI
11/86
5/87
5/87 LI
LI
LI
JBK Inspection Service, Inc.
(The Bid. Inspector of America
225B CottrelI Road
Matawan, NJ 07747
Barry Benevento
(201) 525-9140
JRW Industries, Inc.
2312 North Second Street
Harrisburg, PA 17110
James Wi11iams
(717) 236-1418
K t J Solar Service
1142 FiIImore St.
Denver, CO 80206
James VaI astro
(303) 393-8372
KS Dept. of Health ft Environ.
Radiation Laboratory
Forbes Bldg. 740
Topeka, KS 66620
Dr. Dominic To
(913) 862-936O ext 408
KSE, Inc.
P. 0. Box 368
Amherst, MA 01004
Dr. Charles W. Quinlan
(413) 549-5506
Key Technology, Inc.
P.O. Box 662
Jonestown, PA 17038
Claude Wiblin
(717) 274-8310
6/87
LI
6/87
LI
5/87
LI
6/87 LI
X
11/86
6/87
4/86
7/86
11/86
6/87
LI
LI
LI
LI
.Ul
LI
* See TABLE 1 for the States each company serves. . .
Note: Underscored performance indicators denote a primary company capable of performing measurement analyses in house or making measurements
using operators and instruments belonging to the company.
See Definitions of Performance Indicators on pages 5 and 6.
-------
TABLE 2
PERFO«aiANCE RESULTS OF COMPANIES
* Company
Date of Radon Working Lovel
Round Measurement Measurement QA
AT CC CR GR GW RP CW Plan
* Company
Date of Radon Working Love I
Round Measurement Measurement QA
AT CC CR GR GW RP CW Plan
Lamson Homo Inspections
9 Lougheed Avenue
West CaIdwell, NJ 07006
Wi11iam M. Lamson
(201) 228-1862
Lapteff Associates
P.O. Box 4160
Woodbridge, VA 22194
Dr. Alexander Lapteff
(703) 491-6700
M.V.E., Inc.
1911 Lelaray Street
Colorado Springs, CO 8O9O9
£ Mr. Kent Rockwell
(303) 635-B736
MIT/MIT Radon Project
Building 26, Rra # 421
Cambridge, MA O2139
Professor Lea Grodziris
(817) 253-4151
MRC Home Inspections
P. 0. Box 157
Wyckoff, NJ 07481
Henry H. Doron
(201) 891-7057
Madrona Divirsified, Inc.
1938 Fairview'Ave. East
Seattle, WA 98102
Dr; Samuel E. Kelly
(206) 324-O92O
6/87 LI
11/88 LI
S/87 Ll
5/87 Ll Ll
6/87 Ll
Ll
5/87 Ll
5/87 Ll
Maine Public Health Laboratory 6/87 Ll
Statehouse Station #12
Augusta, ME 04333
Cheryl L. Baker
(207) 289-2727
Ll
LA
Microbac Labs, Erie Testing Lab Div 11/86
2411 W. 26th St. 6/87
Erie, PA 16506
Jeffrey Ports
(814) 833-4790
Microbac Labs, Hanover, PA 6/87 Ll
701 3rd. Street
Hanover, PA 17331
Ronald M. Barber
Not Installed Yet
Microbac Labs, MA Testing Division 6/87 Ll
202 Bussey Street
Dedham, MA 02021
Andrew W. Niemann
(617) 326-7117
Microbac Labs, New'Castle, PA 5/87 Ll
R. D. #3, Pulaski Road
New Castle, PA 16105
Mary V. Wo Iford
(412) 664-4212
Microbac Labs, Pittsburgh, PA 5/87 Ll
4580 McKnight Road
Pittsburgh, PA 15237
William A. Larid
(412) 931-5851
f Soe TABLE 1 for the States each company serves'!' ' "'" "'' " ..--..,
Note: Underscored performance indicators Denote a primary' company'capablo of performing measurement analyses in house or making measurements
using operators and instruments belonging to the company. " max ing measurements
See Definitions of Performance Indicators on pages 5 and 6.
-------
TABLE 2
PERFORMANCE RESULTS OF COMPANIES
* Company
Date of "- ' Radon Working Level
Round ' -Measurement Measurement QA
AT CC CR GR CHI RP CW Plan
Date of
Round
* Company
Radon
Measurement
AT CC CR GR
- Work i ng LeveI
Measurement QA
GW RP CW Plan
Microbac Labs, Schiller Div. 5/67 LI
449 Rochester Road
Pittsburgh, PA 16237-1733
David J. Danis, Lab Director
(412) 369-4830
Microbac Labs, Seaway Div 6/87
542-644 Conkey Street
Hammond, IN 46324
LI
National Radon Control, Inc.
P.O. Sox 6342
North Branch, NJ 08876
David T. deNeufville
(201) 231-O844
Natural Resource Technologies
32131 Steven Way
Conifer, CO 8O433
4/86
7/86
11/86
6/87
6/87
LI
LI
LI
LA
LI
Karen A. Erny
(219) 932-1770
NC Dept. of Human Resources
Radiation Protection Section
701 Barbour Drive
Raleigh, NC 27603-2008
on Harry J. Newman
(919) 733-4283
NJ DEP - Bureau of Env. Radiation
CN 411
Trenton, NJ 08625
Al Ian J. Dean
(609) 630-4001
NJ Dept of Environmental Protection
Environmental Laboratory
380 Scotch Road
Trenton, NJ 08628
Ms. Patricia Gardner
(609) 630-4116
NODAR, Inc.
Route 6 Box 333R
Athens, AL 35611
Wi 1 1 iam Young
(205) 729-1900
11/86
6/87
4/86
7/86
11/88
6/87
4/86
7/86
11/86
6/87
11/86
6/87 .
LI
LI
LI LI
LI- LI
LI LI
LI LI LI
LI
LI
LI
U
LI
LA
George H. Sylvester
(303) 860-9336
New England Radon, LTD. 11/86 LI X
373 Main St. 6/87 LA
Salem, NH O3079
Daniel Espinal
(6O3) 893-4260, (800) 637-2366
New York State Dept. of Health 6/87 LI
Radiological Sciences Lab
Empire State Plaza, Room D-366-B
Albany, NY 12201
Robert J. Mahoney
(618) 474-2134, (618) 474-6649
Niton Corporation 5/87 LI LI
P. 0. Box 9163
Lexington, MA 02173
James Wi 1 1 iams
(617) 229-4929
Northeast Radon Testing Svc., Inc. 5/87 LI
P. 0. Box 94
Stormville, NY 12582
Karen A. Bard
(914) 221-0236
» See TABLE 1 for the States each company serves. _
Note: Underscored performance indicators denote a primary company capable of performing measurement analyses in house or making measurements
using operators and instruments belonging to the company.
See Definitions of Performance Indicators on pages 5 and 6.
-------
TABLE 2
PERFORMANCE RESULTS OF COMPANIES
* Company
Data of Radon
Round Measurement
AT CC CR GR
Working Level
Measurement QA
GW RP CW Plan
Northeastern PA Envir. Council
P. 0. Box 3113
Scranton, PA 18505
Edward Dructor
(717) 961-1150
Nuclear Radiation Center
Washington State University
Pullman, WA 99164-1300
6/87
LI
5/87
LI
Roy FiI by
(509) 335-8917
(509) 335-8641
Nuclear Sources & Services Inc.
P. 0. Box 34042
Houston, TX 77234
en Charles T. Gallagher
(713) 641-0391
11/86 LI
5/87 LA
» Company
Phoenix Labs
L. Rorbes Road
Rout* 1, Box 247
Colebrook, NH 03576
GiIbert McCarthy
(603) 237-5773
Princeton Home Inspection Svc.
360 Nassau Street
Princeton, NJ 08540
Clive Usiskin
(609) 921-3775
Princeton Testing Laboratory
Princeton Service Center
3490 US Route 1
Princeton, NJ 08540
Mr. Anthony Damato
(609) 462-2037
Date of Radon
Round Measurement
AT CC CR GR
Working Level
Measurement QA
GW RP CW Plan
6/87
LI
6/87
LI
11/86
5/87
LI
LI LA
Nucleon Lectern Associates, Inc.
2919 Olney-Sandy Spring Road
Suite D
Olney, MD 20832
Michael S. Terpi lak
(301) 774-3301 "
0. K. Rems Corp.
174 Flock Rd.
Mercerville, NJ 08619
Jeffrey C. Olcott
(609) 588-9627
Oak R-idge Assoc. Universities
Professional Training Progress
P. 0. Box 117
Oak Ridge, TN 37831-0117
E Ibert Carl ton
(616) 576-5517
4/88
7/86
11/86
5/87
7/86
11/88
6/87
5/87
LI
LI
LI
LI LI LI LI
LI LI
LI LI
LI LI
LI
Protect-A-Home 6/87 LI
P. 0. Box 584
Newtown, CT 06470
B. Michael MeeKan
(203) 426-3000
Pylon Electronic Development 5/87 LI LI X
147 Colonnade Rd.
Nepean, Ont., Canada K2E7L9
Dave Hanneson
(613) 226-7920 j
Pyramid Environmental Systems, Inc. 7/86 LI
P. 0. Box 548 11/86 LT
Sparta, NJ 07871 6/87 LI
Jeffrey R. DeChacon
(201) 729-9375
* Sea TABLE 1 for the States each company serves.
Note: Underscored performance, indicators denote a primary company capable of performing raasurement analyses in house or making measurements
using operators and instruments belonging to the company.
See Definitions of Performance Indicators on pages 5 and 6.
-------
TABLE 2
PERFORMANCE RESULTS OF COMPANIES
* Company
Date of " Radon
Round ' Measurement
AT CC CR GR
Working Level
Measurement QA
' , RP CW Plan
* Company
Date, of Radon
Round Measurement
AT CC CR GR
Working Level
Measurement QA
GW RP CW Plan
R.A.D. Service ft Instruments Ltd.
50 Silver Star Blvd., Unit 208
Scarborough, Ontario M1V2W4
Canada
Dr. H. L. Pai
(416) 298-9200
R.J. Moore ft Associates, Inc.
1010 West Street
Annapolis, MD 21401
Roderic E. Ordway
(301) 269-5S50
RAD Environmental Services
2306 Rodeo Drive
Durham, NC 27704
CO
Dr. Marc Y. Menetrez
(919) 688-9226
RADON Home Inspection Service
P.O. Box 65
Damascus, MD 20872
Richard K. Jock
(301) 253-0029
RADON SURVEY SYSTEMS, Inc.
Div. of Terradon Exploration Tech.
P. 0. Box 22288
Cleveland, OH 44122
Dr. Darioush T. Ghahremani
(216) 464-7997
RAF Engineering
Hillside Road
Rockaway, NJ 07866
Ralph Favale
(201) 983-9041
7/86 LI
11/86 LI
5/87 LI
11/86 LI LI
5/87 LI LI
5/87 LI LI LI LI LI JL1 X
11/86
6/87
6/87 LI LI
LI
LI
5/87 LI LI
RISE 6/87 LI
280 Broadway
Providence, RI 02903
John Masiello
(401) 272-1040
Rad-Elec, Inc. . 6/87 LI LI
124 North Barry Street
Olean, NY 14760
John C. Dempsey
(716) S4S-S012
Rod-Test, Inc. 5/87 LI
P. 0. Box 22576
Louisville, KY 40222
Jeffrey L. Tallent
(502) 368-6996
Radiation Data 5/87 LI
Div. Princeton Geophysical Svc
1200 State Road
Princeton, NJ 08640
Thomas Van Leeuwen
(609) 921-7061
Radiation Protection Services 11/86 LI
P. 0. Box 2395 5/87 LI
Darien, CT 06820-1295
Michael L. Caprio Jr.
(203) 324-7967
Radiation Safety Associates, Inc. 6/87 LI
P. 0. Box 107
Hebron, CT 06248
Paul Steinmeyer
(203) 228-O487
* See TABLE 1 for the States each company serves.
Note: Underscored performance indicators denote a primary company capable of performing measurement analyses in house or making measurements
using operators and instruments belonging to the company.
See Definitions of Performance Indicators on pages 5 and 6.
-------
TABLE 2
PERFORMANCE RESULTS OF COMPANIES
* Company
Radiation Safety Engineering
6105 South Ash, Suite 1
Tempe, AZ 85283
Robert Metzger
(602) 897-9469
Radiation Safety Services, Inc.
1564 Ashland Avenue
Evanston, IL 60201-4070
Radon Coordinator
(312) 866-7744
.Radiation Service Organization
P.O. Box 1526
Laurel, MD 20707-7444
LO Kai-Dee Chu
Date of
Round
1 11/86
6/87
Radon
Measurement
AT CC CR GR
LI
LI
Working Level
Measurement QA
GW RP CW Plan
X
* Company
Radiological Physics Services
Health East, Inc.
Date of
Round
5/87
Radon
Measurement
AT CC CR GR
Ll
Working Level
Measurement QA
GW RP CW Plan
7/86
11/86
5/87 Ll
Ll
Ll
LA
oo
(301) 953-2482
Radiation Services Inc.
3412 Doriswood Ct.
Antioch, TN 37O13
Michael C. Bradshaw
(615) 361-6492
Radiation Surveys Incorporated
63 Kingwood Ave.
rVenchtown, NJ 08825
Carolyn Davis
(201) 996-3855
Radioactivity Alert Detection Serv.
1313 Roberts Ave.
Feasterville, PA 19047
Garry Stklovsky
(215) 357-0574
4/86
7/86
11/86
6/87
5/87
Ll
Ll
Ll
Ll
Ll
7/86
11/86
5/87 Ll
6/87 Ll Ll
Ll
Ll
Ll
Ll
Ll Ll
P. 0. Box 13387
Roanoke, VA 24033
Joseph . Surace
(703) 981-7379
Radon A Environ. Professionals 11/86
1902A Kentucky St. 6/87
Lawrence, KS 66044
Linda Guinn
(913) 749-7920 (316) 265-2005
Radon Air Pollution Testing Co, Inc 6/87 Ll Ll
1499 Lakeview Drive
Mt. Juliet, TN 27122
Carlotta Bogart
(615) 768-9392
Radon Alert Detection Center
P. 0. Box 323
Flourtown, PA 19031
Ulrich W. Hiesinger, Ph.D.
(800) 345-6348 (215) 247-9197
Radon Ana lists, Inc.
P. 0. Box 509
Livingston Manor, NY 12758
Vincent J. A. Santoro
(914) 439-5111 (914) 292-2277
Radon Analysis Incorporated 7/86 Ll
RR#1 Box 561M Fox Run Road 11/86 Ll
StewartsviIle, NJ 08886 5/87 Ll Ll
David Chippendale
(201) 479-6086
7/86 Ll
11/86 Ll
5/87 Ll Ll
7/86
11/86
5/87
Ll
Ll
Ll
* See TABLE 1 for the States each company serves. ' -'
Note: Underscored performance indicators denote a primary company capable of performing measurement analyses in house or making measurements
using operators and instruments belonging to the.'company.
See Definitions of Performance Indicators on pages 5 and 8.
-------
. TABLE 2
-PERFORMANCE RESULTS OF COMPANIES
* Company
Date of Radon
Round Measurement
AT CC CR GR
Working Level
Measurement QA
GW RP CW Plan
Company
Date of Radon
Round Measurement
AT CC CR GR
Working Level
Measurement QA
GW RP CW Plan
Radon Consultants, CO
P. 0. Box 789
Golden, CO 8402
Dennis N. Poffenroth
(303) 279-1358
Radon Consultants, Inc., VA
4012 N. 35th Street
Arlington, VA 22207
Dr. Jacquelyn G. Black
(703) 522-6669 (301) 736-7040
Radon Detection Services, Inc., GA
1729 Coventry Place
Decatur, GA 30030
cj Barrett Walker
^ (404) 377-2366
Radon Detection Services, Inc., MD
P. 0. Box 1195
Laurel, MD 20707
Tom Hoy
(301) 725-2901
Radon Detection Services, Inc., NJ
P.O. Box 419
Ringoes, NJ 08551
James G. Davidson
(201) 788-3080
Radon Detection Services, Inc., PA
P. 0. Box 3309
A lien town, PA 18106
Bruce E. Barker
(215) 481-9655
6/87 Ll Ll
11/86 Ll Ll
6/87 Ll Ll
11/86 Ll Ll X
5/87 Ll LA
11/86 Ll Ll Ll Ll Ll X
5/87 Ll LA Ll Ll Ll
4/86 Ll Ll Ll Ll X
7/86 Ll Ll Ll Ll
11/86 Ll Ll Ll Ll
6/87 LA LA Ll i-1
11/86 Ll Ll Ll Ll X
6/87 Ll Ll LJ. Ll
Radon Detection Specialists 11/86 Ll X
7966 South Madison Street 6/87 Ll
Burr Ridge, IL 60521 '
Karl Weber
(312) 325-4443
Radon Detection Systems Inc., OH 5/87 Ll
P. 0. Box 473
Aurora, OH 44202
Sandra Sawyer
(216) S62-4647
Radon Detection Systems of TN 5/87 Ll Ll LJ.
3102 Bel (wood Ave. Suite B
Nashville, TN 37203
Walter Perkins / Odom Clark
(615) 269-4616
Radon Detection Systems, CO 7/86 Ll Ll
2300 Central Avenue Suite B-l 11/86 Ll Ll Ll
Boulder, CO 8O301 5/87 Ll Ll LJ.
Tim Smith
(303) 444-6253
Radon Detection and Control 5/87 Ll
P. 0. Box 222
Georgetown, PA 15043
John B. Mai Ion Jr.
(412) 573-0202
Radon Detection, Inc. 5/87 LJ.
131 Amherst Street
P. 0. Box 900
Amherst, NH 03031-0900
Luc i an Borduz
(803) 882-7340
* See TABLE 1 for the States each company serves.
Note: Underscored performance indicators denote a primary company capable of performing measurement analyses in house or making measurements
using operators and instruments belonging to the company.
See Definitions of Performance Indicators on pages 5 and 6.
-------
TABLE 2
PERFORMANCE RESULTS OF COMPANIES
* Company
Date of Radon
Round Measurement
AT CC CR GR
Working Level
Measurement QA
GW RP CW Plan
Radon Diagnostics 5/87 LI
Box 761
Andover, NJ 07821
Charles R. Wayne, Jr.
(201) 729-1261
Radon Engineering Services Inc 5/87
3129 Overton Rd.
Birmingham, AL 35223
Dr. F. Mi Iton Jessup, P.E.
(205) 967-2665
LI
4/86
7/86
11/86
5/87
5/87
Radon Engr, a Unit of PSI Engr, Inc
One Lethbridge Plaza
Mahwah, NJ 07430
.p> Harvey Greenberg, P.E.
0 (201) 529-8300
Radon Env. Test Experts, Inc.
5271 Holmes PI.
Boulder, CO 80303
David Oppenheimer
(303) 442-2344
Radon Environ. Monitoring, Inc 5/87 Ll
Box 5305
Evanston, IL 6O2O4
Robert Pol lock
(312) 328-6628
Radon Gasbusters 11/86
513 Lyons Avenue 5/87
Irvington, NJ 07111
Michael Keilison
(201) 375-3710
Ll Ll
Ll Ll
Ll Ll
Ll Ll
LI
LI
Li
LI
LI
LI
LI
* Company
Date of Radon Working Level
Round Measurement Measurement QA
AT CC CR GR GW RP CW Plan
Radon Inspection Service
789 East Glen Avenue
Ridgawood, NJ 07450
Robert D. Shumeyko
<201) 670-8821
Radon Management Company
4332 Gingham Court
Alexandria, VA 22310
Gordon M. Davidson
(202) 547-1005 (703) 960-4407
Radon Management Laboratories
2 Riverdale Road
Pompton Lakes, NJ 07442
James Matonti, Joseph Fastiggi
(201) 835-8721
Radon Measurement ft Control
7935 Ki(bourne Rd.
Sunbury, OH 43074
John R. Hunt
(614) 866-1197
Radon Measurement and Control
of New Mexico
1527 Granite St. NW
Albuquerque, NM 87104
Dr. William M. Turner
(505) 843-7305
Radon Measurement and Services
13131 West Cedar Drive
Lakewood, CO 80228
R. Stanley Thompson
(303) 980-6088
4/86 LI U
7/86 LI Ll LI ,L1
11/88 Ll Ll Ll Ll
6/87 Ll Ll Ll Ll Ll
11/86
5/87
5/87
Ll
Ll
Ll
Ll Ll
11/86
5/87
5/87 Ll
U
LA
4/86 Ll
7/86 Ll
11/86 Ll Ll
5/87 Ll LA
Ll Ll
. * See TABLE 1 for the States each company serves.
Note: Underscored performance indicators denote a primary company capable of performing measurement analyses in house or making measurements
using operators and instruments belonging to the company.
See Definitions of Performance Indicators on pages 6 and 6.
-------
TABLE 2
PERFORMANCE RESULTS OF COMPANIES
* Company
Date of , . Radon
Round Measurement
AT CC CR GR
Working Level
Measurement QA
GW RP CW Plan
Date of
Round
* Company
Radon
Measurement
AT CC CR GR
Working Level
Measurement QA
GW RP CW Plan
Radon Measurements Inc. 5/87 LI LI
2916 West T. C. Jester
Houston, TX 77018
John H. Cohen
(713) 683-8227
Radon Mitigators, Inc. 5/87 LI
16 Hillside Drive
Clinton, NJ 08809
Lawrence K. Kaplan
(201) 730-6596
Radon Project, The S/87 LI
P. 0. Box 90069
Pittsburgh, PA 15224
£., Bernard L. Cohen
- (412) 687-3393
Radon Registry 5/87 LI
819 Second St. B-178
Manchester, NH 03102
Tom Roller
(603) 645-6780
Radon Research Group 7/86 LI
P.O. Box 1143 11/86 LI
Germantown, MD 20874 5/87 LI
Michael J. Myers
800/445-8436, MD 800/644-8436
Radon Safety Services, Inc. 7/86
Box 441 11/86
New Providence, NJ 07974 5/87 LI
Guy J. Agrati
(201) 826-8267 (201) 665-1188
LI LI
LI LI
LI LI
Radon Screening Service, Inc. 6/87 LI LI
P. 0. Box 37007
Denver, CO 80237
Thomas Staley
(303) 741-3207
Radon Surveys, Div. Alpha Tech Corp 11/86
2205 13th Street 6/87
Winthrop Harbor, IL 60096
Steven P. Ray
(312) 872-3663
Radon Surveys, Div. Cope Tech Svcs 6/87 LI
3506 87th PI.
Kenosha, WI 63142
James L. Cope
(414) 694-3730
Radon TNT 11/86
1015 Beta Loop 6/87 LI
Colorado Springs, CO 80906
Richard Cole
(303) 520-6693
LI
LI
LI
LI
5/87 LI LI LI
Radon Technologies Inc.
39 Woodrow Court
Troy, NY 12180
Robert J. Mahoney
(518) 447-5834
Radon Testing Corp. of America RTCA 7/86 LI
12 W. Main Street 11/88 LI
Elmsford, NY 10523 5/87 LI
Nancy A. Bredhoff
800/457-2366, 800/537-7822 -NY
* See TABLE 1 for the States each company serves.
Note: Underscored performance indicators denote a primary company capable of performing measurement analyses in house or making measurements
using operators and instruments belonging to the company.
See Definitions of Performance Indicators on pages 5 and 6.
-------
TABLE 2
PERFORMANCE RESULTS OF COMPANIES
* Company
Date of Radon
Round Measurement
AT CC CR GR
Working Level
Measurement QA
GW RP CW Plan
* Company
Date of Radon Working Level
Round Measurement Measurement QA
AT CC CR GR GW RP CW Plan
Radon Testing Svc, Englewood, CO 6/87 LI
P. 0. Box 1130
Englewood, CO 80110
David L. Eg Iaston, Jr.
- (303) 762-8598
Radon Testing Svc, Pittsburgh, PA 11/86 LI
P. 0. Box 19425 5/87 LI
Pittsburgh, PA 15213
Mark Johnson
(412) 687-1533
Radon Testing Svcs, Baltimore, MO 5/87 LI
P. 0. Box 7999
Baltimore, MD 21221-0999
^ Laurence V. Kolego
^ (3O1) 321-8008
Radon Testing Svcs, Princeton, NJ 5/87 LI
P. 0. Box 3311
Princeton, NJ 08543
Rodney T. Mi Iler
(609) 737-8818
Radon X Company, Inc., The 5/87
217 Roxbury Street
Keene, NH 03431
David P. Tkatch
(603) 352-5319
Radonics, Inc. 11/86 LI LI
(Div. of Gemini Research) 5/87 LI LI
5101-D Back lick Road
Annandale, VA 22003
Brian P. Fimian
703/941-O07O 800/8-RADON-O
LI
LI
LI
LA
LI X
LA
Radon ix 5/87 LI
34 Dogwood Lan«
Middletown, PA 17057
Edward V. Kellogg
(717) 944-5520
Rain Exterminators 5/87 LI
97 Frank St.
Somerset, NJ 06873
James R. Savage
(201) 937-6900
Real Estate Support Services 11/86 LI
7901 Flying Cloud Drive, #132 5/87 LI
Eden Prairie, MN 55344
Julie Steen
(612) 941-7558
Recon Systems, Inc. 7/86 LI
P.O. Box 460 11/86 LI LI
Three Bridges, NJ O8887 5/87 LI LI
Peter L. Rosen
(2O1) 782-6900
Res-I-Tec 6/87 LI
94 LimkiIn Road
Redding, CT 06896
Ron Passaro
(203) 938-9811
Residential Radon Measurements 6/87 LI LI
P. 0. Box 3051
Fairview Heights, IL 62208
Todd A. Jokerst
(618) 397-0099
* See TABLE 1 for the States each company serves.
Note: Underscored performance indicators denote a primary company capable of performing measurement analyses in house or making measurements
using operators and instruments belonging to the company. :
See Definitions of Performance Indicators on pages 5 and 6.
-------
' TABLE 2
PERFORMANCE RESULTS OF COMPANIES
* Company
Date of Radon
. Round..-.. -Measurement
AT CC CR GR
Working Level
Measurement QA
GW RP CW Plan
* Company
Date of Radon
Round Measurement
AT CC CR GR
Working Level
Measurement QA
GW RP CW Plan
Residential Radon Test Service 6/87
126 Old Oaken
Scituate, MA
Bucket Raod
O2068
LI Ross Systems, Inc.
174 Route 94
Blairstown, NJ 07825
4/86
7/86
11/86
B/87
LI
LI
LI
LI
LI
LI
LI
LI
LI
LI
LI
LI
LI
Jim Wood
(617) 645-9160
Reynolds Radiological Services, Inc 7/86
RD 1 Box 271-5 11/86
Bainbridge, PA 17502 5/87
H. W. Reynolds
(717) 653-9366 (717) 367-7829
Roberts Environmental Services 11/88 LI
4110 Old Wake Forest Road 5/87 LI LI U. LI
Suite 109
Raleigh, NC 27609
.p, Glenn David Osmond
00 (919) 790-9378
Rocky Mountain Radon Testing 5/87 LI
6820 S. Brook Forest Dr.
Evergreen, CO 8O439
Duane A. Riggenbach
(303) 674-7029
LI
LI
LI
LI
LI
LI
Rogers ft Assoc. Engineering Corp. 7/86 LI
515 East 4500 South, Suite G-200 11/86 LI NL
Salt Lake City, UT 84107 6/87 LI LI
Dr. Kirk X. Nielson
(801) 263-1600
Ronald Stein Construction Inc. .5/87 LI LI
21 Davis Ave.
Poughkeepsie, NY 12603
- Ronald Stein
(914) 473-0064
LI
LI
Richard Ross
(201)-364-6571
Roy F. Weston, Inc. 11/86
One Weston Way (Bldg. 4-2) 5/87
West Chester, PA 19380
Jean-Claude F. Dehmel
(216) 692^3030 ext 2746
Ryan Nuclear Laboratories 5/87 LI
7030 D Hunt ley Rd -'
Columbus, OH 43229
Wayne Ballantyne
(614) 848-4414
S. C. Dept of Health A Env Control 5/87 LI
Bureau of Radiological Health
J. Marion Sims Bldg.
Columbia, SC 29201
Nolan Bivens
(803) 734-4700
Safe ft Sound Home Inspect. Con 5/87 LI
P. 0. Box 195
Cedar Knolls, NJ 07927
Steven W. Freedman
(201) 515-0013
Safe Air 5/87 LI
P. 0. Box 120064
Nashville, TN 37115
Carolyn Tompkins .
(615) 865-6325
LI
LI
LI
LI
* See TABLE 1 for the States each company serves.
Note: Underscored performance indicators denote a primary company capable of performing measurement analyses in house or making measurements