oEPA
         United States
         Environmental Protection
         Agency
                Office of Water
                (WH-552)
EPA-821-R-93-009
June 1993
Preliminary Report of EPA Efforts to
Replace Freon For The Determination
of Oil and Grease

-------
DISCLAIMER

This report has been reviewed by the Analytical Methods Staff of the EPA Office of Water.  It is a
preliminary report intended to provide information on the current status of this study.  Evaluation of
the data collected under this study is ongoing.  Mention of company names, trade names or
commercial products does not constitute endorsement or recommendation for use.

Questions or comments regarding this report should be addressed to:

William A. Telliard, Chief
Analytical Methods Staff
Engineering and  Analysis Division (WH-552)
Office of Science and Technology
U.S. EPA Office of Water
401 M Street,  S.W.
Washington, D.C. 20460
ACKNOWLEDGEMENTS

This study was the result of a cooperative effort between the EPA Office of Water, Office of Solid
Waste and Emergency Response, Office of Air and Radiation, and Office of Research and
Development.  This report was prepared under the direction of William A. Telliard with assistance
from the Environmental Services Division of DynCorp Viar, Inc. (under EPA contract no. 68-C9-
0019), and its subcontractors: Interface Inc., Environmental Survey Associates, SRI International,
Skinner  and Sherman Laboratories, ETS Analytical Services, and the Geochemical and Environmental
Research Group of Texas  A&M University.  Other contributors to this study  included the EPA
Central Regional Laboratory  in Annapolis, MD, the 3M Corporation, Horiba Instruments, and Varian
Sample Preparation Products.

-------
                                                          TABLE OF CONTENTS
Executive Summary	    1

Section 1 Background	    3

Section 2 Phase I Study Design	    5
     2.1   Study Objectives  	    5
     2.2  Sample Source Selection	    5
     2.3  Analytical Study Design	    6

Section 3 Field Sampling	   11

Section 4 Data Validation and Statistical Analysis 	   13
     4.1   Data Validation	   13
     4.2  Statistical Analysis	   13

Section 5 Discussion  	   19
     5.1   Separatory Funnel Extraction of Aqueous Samples	   19
     5.2  Soxhlet and Sonication Extraction of Solid Samples  	   20
     5.3  Solid Phase Extraction (SPE) of Aqueous Samples  	   20
     5.4  Non-Dispersive Infrared Analysis of Aqueous Samples	   22
     5.5  Graphical Presentation of RMSD  Versus Acceptance Limit Results	   22
     5.6  Graphical Presentation of the Solvent-Freon Ratios	   22

Section 6 Phase I Study Conclusions  	   39
     6.1   Alternative Solvents for Existing  Methods 413.1, 9070 and 9071A	   39
     6.2  Sonication as an Alternative Technique to Soxhlet Extraction	   40
     6.3  Alternative Techniques for Aqueous Samples	   40
     6.4  Retention and Elimination  of Solvents for Further Study   	   40
     6.5   Retention of Alternative Techniques for Further Study	   41

Section 7 Follow-Up and Possible Phase II Activities  	   43

Appendix A Site Summary

Appendix B Data Summary

Appendix C Discussion of Statistical Techniques Used in the Preliminary Data Evaluation

-------
                                 LIST OF EXHIBITS
Exhibit 1:     Solvent RMSDs for Conventional Techniques
Exhibit 2:     Relative Percent Deviation vs. Concentration
Exhibit 3:     Summary Statistics for Alternative Solvents in the Determination of Oil and
             Grease - Aqueous Waste Stream, Separatory  Funnel Extraction
Exhibit 4:     Summary Statistics for Alternative Solvents in the Determination of Oil and
             Grease - Solid Waste Stream, Soxhlet Extraction
Exhibit 5:     Summary Statistics for Alternative Techniques in the Determination of Oil
             and Grease - Solid Waste Stream, Sonication  Extraction
Exhibit 6:     Summary Statistics for Alternative Techniques in the Determination of Oil
             and Grease - Aqueous Waste Stream, 90 mm Solid Phase Extraction Disk
Exhibit 7:     Summary Statistics for Alternative Techniques in the Determination of Oil
             and Grease - Aqueous Waste Stream, 45 mm Solid Phase Extraction Disk
Exhibit 8:     Summary Statistics for Alternative Techniques in the Determination of Oil
             and Grease - Aqueous Waste Stream, SPE Column (old version)
Exhibit 9:     Summary Statistics for Alternative Techniques in the Determination of Oil
             and Grease - Aqueous Waste Stream, SPE Column (new version)
Exhibit 10:   Summary Statistics for Alternative Techniques in the Determination of Oil
             and Grease - Aqueous Waste Stream, Infrared Analysis
Exhibit 11:   Root Mean Square Deviations - Aqueous Waste Stream,  Separatory Funnel
             Extraction
Exhibit 12:   Root Mean Square Deviations - Solid Waste Stream, Soxhlet Extraction
Exhibit 13:   Root Mean Square Deviations - Solid Waste Stream, Sonication Extraction
Exhibit 14:   Root Mean Square Deviations - Aqueous Waste Stream,  Alternative
             Techniques, Non-Petroleum Samples
Exhibit 1 5:   Root Mean Square Deviations - Aqueous Waste Stream,  Alternative
             Techniques, Petroleum Samples
Exhibit 1 6:   Mean Solvent-Freon Ratios for All Techniques Tested
Exhibit 17:   Summary of Solvents and Conventional Techniques with RMSDs Within the
             Acceptance Limit

Exhibit A-1:   Site Summary Freon  Replacement Study
Exhibit A-2:   Wastewater Sources Freon Replacement Study

-------
                                                                 EXECUTIVE  SUMMARY
       The Clean Air Act Amendments of 1990 (CAAA) require that use of Class I
chlorofluorocarbons (CFCs)  which deplete the ozone layer be phased out by 1996. Freon 113
(trichlorotrifluoroethane) is a Class I CFC that is required by present U.S. Environmental Protection
Agency (EPA) wastewater and solid waste methods for measurement of the conventional pollutant "oil
and grease". This report provides the results of Phase I of EPA's study to replace Freon 113 in the
determination of oil and grease.
       The objective of Phase I was to find a solvent or solvents that would produce results nearly
identical to the results produced by Freon 113 in the oil and grease measurement. Solvents evaluated
were n-hexane, n-hexane plus methyl tertiarybutyl ether (MTBE) in an 80/20 mixture, DuPont 123
(2,2-dichloro-l,l,l-trifluoroethane), methylene chloride, and perchloroethylene (tetrachloroethene).
Solvents were evaluated by comparing results from triplicate extraction of 40 wastewaters and 28
solid/sludge wastes, from 39 industrial facilities  in 24 industrial categories, to the results produced by
extraction of these same samples with Freon 113.
       In addition to testing the solvents listed above, sonication extraction, solid phase extraction
(SPE) using cartridges and disks, and a proprietary solvent/non-dispersive infrared technique were
tested on a subset of samples.

Alternative Solvents

       Results were stratified according to extraction solvent and technique, and within this
stratification, into three categories:  all samples, petroleum-based samples, and non-petroleum based
samples, depending on whether the oil and grease was of animal, vegetable, or mineral origin.
       Data from solvent comparisons in the Phase I study are summarized in Exhibit 1 and show
that the results produced by n-hexane, perchloroethylene, and the 80/20 mixture of n-hexane and
MTBE are not statistically different from the results produced by Freon 113 (i.e., within the
Acceptance Limit) for some sample strata, whereas the results produced by methylene chloride and
DuPont 123 are not within this limit.
       Based on these results and on the results of a preliminary study by EPA's Environmental
Monitoring Systems Laboratory in Cincinnati, Ohio (EMSL-Ci),  EPA will retain or eliminate certain
solvents and techniques from further consideration as  candidates  for replacement  of Freon 113 in the
oil and grease measurement,  as follows:

       1.  n-hexane will be retained because the results for petroleum-based solid samples  and non-
           petroleum aqueous samples are within the Freon 113 Acceptance Limit and because n-
           hexane was used in the oil and grease measurement prior to the advent of Freon 113.

       2.  Perchloroethylene will be retained because the results for non-petroleum aqueous samples
           are within the Freon 113 Acceptance Limit and because perchloroethylene can be used in
           the measurement of oil and grease by infra-red techniques.
June 1993

-------
Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
        3.  n-hexane/MTBE (80/20) will be retained because the results for petroleum-based solid
            samples are within the Freon 113  Acceptance Limit and because 80/20 is the solvent
            developed by EMSL-Ci in the preliminary study.

        4.  Methylene chloride will be eliminated because the results produced are far from results
            produced by Freon 113.

        5.  DuPont 123 will be eliminated because results produced using this solvent are not within
            the Freon 113 Acceptance Limit for any category of solid or aqueous samples and because
            DuPont 123 is a Class II CFC that will need to be phased out eventually.

Alternative Techniques

        Of the alternative techniques evaluated in this study, only sonication extraction of non-
petroleum solid samples produced results equivalent to existing techniques with Freon 113. The use of
smaller solvent volumes required by solid phase extraction (SPE) and the increased sensitivity of the
non-dispersive infrared technique might warrant further  study.

                                              Exhibit 1.
         Solvent Root Mean Square  Deviation (RMSDs) for Conventional Techniques
               80/20
              DuPont
             Perchlor
                                                                          Technique
                                                               Matrix   Aqueous   Soxhlet
                                                             Non-Petroleum   O      a
                                                              Petroleum     •      •
[01
               MeCh
              Hexane
            Acceptance
               Limit
                         I	•	1	1	1	'	[	'	1
                         12345

                                          Normalized Root Mean Square Deviation

            NOTE:  Acceptance Limits for Freon 113 in each stratum (petroleum or non-petroleum) are shown by dotted vertical lines.
                  RMSDs to the left of the respective Acceptance Limit indicate that the alternative solvent produces results
                  equivalent to Freon 113 for that stratum, whereas RMSDs to the right of the respective Acceptance Limit indicate
                  degrees of lesser agreement, with the least agreement being farthest to the right (highest RMSD).
                                                                                           June 1993

-------
                                                                               SECTION  1
                                                                           BACKGROUND
       Chlorofluorocarbons (CFCs) have been shown to be primary contributors to the depletion of
the earth's stratospheric ozone layer. The United States, as a party to the Montreal Protocol on
Substances that Deplete the Ozone Layer and as required by law under the Clean Air Act
Amendments of 1990 (CAAA), is committed to controlling and eventually phasing out CFCs. Under
both the Montreal Protocol and the CAAA, Class I CFCs will be phased out by January 1, 1996. To
be consistent with its commitment to control and phase out CFC use, the U.S. Environmental
Protection Agency (EPA) is investigating the use of alternative solvents in lieu of Freon 113, a CFC
that is mandated in EPA methods for the determination of "oil and grease".
       Currently, three Agency methods are used for regulatory compliance monitoring
determinations of oil and grease content in environmental samples. They are Method 413.1,
promulgated at  40 CFR Part 136, and Methods 9070 and 9071A, promulgated at 40 CFR Parts 260-
270 (EPA Publication SW-846 by reference). Method 413.1 is used in  Clean Water Act (CWA)
programs to determine total oil and grease content in surface and saline waters and in industrial and
domestic wastes. This gravimetric method involves acidification of the  sample, serial extraction of the
oil  and grease with Freon 113 in a separately funnel, evaporation of the solvent from the extract, and
weighing of the residue. Method 9070 is used in programs administered under the Resource
Conservation and Recovery Act (RCRA) and is essentially the same as  Method 413.1. RCRA Method
9071A is used to recover low levels of oil and grease from sludges, soils, other solid matrices, and
some industrial wastewaters. The method involves acidification or drying, Soxhlet extraction of oil
and grease with Freon 113, and weighing of the residue after evaporation of the solvent.
       In all three methods described above, the result, termed  "total recoverable oil and grease", is
a method-defined parameter. This means that the result depends  totally on how the measurement is
made. Therefore, changes to the specific analytical protocols have the potential of changing the
numerical value of the results for a given sample.
       Clean Water Act effluent guidelines for 25  major industries include limitations on the
discharge of oil and grease (40 CFR 407-471). Further, oil and grease  is a regulated pollutant in over
10,000 National Pollutant Discharge Elimination System (NPDES) permits and in many RCRA
operating permits. Civil penalties for violation of NPDES and RCRA permits can be severe. The
measurements on which these guidelines and permits are based were made with Freon 113 or, before
1978, with n-hexane as the solvent. The regulated community is concerned that a change in the
solvent used for oil  and grease determinations could cause a change in the results and put their
facilities in violation of NPDES or RCRA permits. In response to this concern, EPA initiated efforts
to identify a replacement solvent or an alternative measurement technique that gives oil and grease
results as close  as possible to those obtained with Freon 113.
       The Agency's initial efforts to find a suitable replacement solvent for Freon 113 were
conducted by the Office of Research and Development's Environmental Monitoring Systems
Laboratory in Cincinnati, Ohio (EMSL-Ci). EMSL-Ci first used laboratory-prepared, synthetic
samples containing materials that represent "oil and grease" compounds covering extremely wide


June 1993                                                                                  3

-------
Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
boiling ranges, such as No. 2 fuel oil, No. 6 fuel oil, Prudhoe Bay crude oil, animal lard, and wheel-
bearing grease. Reagent water was spiked with these materials dissolved in an organic solvent to
simulate real-world samples. These samples were then extracted using several different solvents in
place of Freon 113, and the residues were determined gravimetrically.
        Subsequent evaluations by EMSL-Ci used a limited number of actual industrial waste samples.
The results of EMSL-Ci's work were presented in A Study to Select a Suitable Replacement Solvent
for Freon 113 in the Gravimetric Determination of Oil and Grease, by F. K. Kawahara, October 2,
1991. This study resulted in the preparation of draft Method 413.3, a modification of 413.1 which
utilizes an 80/20 mixture of n-hexane and methyl tertiary butyl ether (MTBE) instead of Freon 113.
        On July 3, 1991, the EPA Office of Air  and Radiation (OAR) proposed (56 PR 30519) to
amend CWA and RCRA analytical methods for oil and grease to require the use of the 80/20 mixture
in lieu of Freon 113. This proposal was based on the findings of the EMSL-Ci studies. Based on
comments received on this proposal, OAR has delayed  any solvent replacement to allow additional
time to study alternatives. In late 1991, the Office of Water (OW) and the Office of Solid Waste
(OSW) began planning a comparative study to collect data in support of OAR's efforts to replace
Freon 113 in Agency oil and grease methods. The remainder of this  document provides a report on
the first phase of that study.
 4                                                                                  June 1993

-------
                                                                                SECTION 2
                                                               PHASE I STUDY DESIGN
        The first phase of the cooperative Office of Water (OW) and Office of Solid Waste (OSW)
 effort involved evaluation of alternative solvents and measurement techniques. The original study
 design is described fully in a study plan dated December 1991'. The final Phase I study design is
 summarized below.

 2.1    Study  Objectives

        The purpose of the first phase of the study was to continue EMSL-Ci's investigation of
 replacement solvents to identify solvents or solvent/extraction systems that provide equivalent
 performance to Freon 113. Specific objectives were to:

        •   Evaluate alternative solvent and solvent/extraction system equivalency across a range of
           real world effluent and solid waste samples from a variety of facility types
        •   Evaluate a series of solvents posing  a lower potential risk to stratospheric ozone
        •   Provide clear direction for  further study of one or two solvents or solvent/extraction
           systems across an even broader range of effluent and solid waste samples that are
           regulated under the Clean Water Act (CWA) and the Resource Conservation and
           Recovery Act (RCRA).

        This effort was intended to be used as a screening study that would be followed by a Federal
 Register notice of the availability of resulting data, development of revised analytical procedures, and
 a confirmation study to support the recommended method revisions.

 2.2    Sample Source Selection

        The kinds of sample matrices included in this first phase of the study represented wastewaters
 and solid wastes from a variety of industrial categories and facilities. A total of 18 facilities were
 originally selected for sampling based on the following considerations:

        •   industrial category
        •   sample matrix (e.g., wastewater, sludge)
    lDraft Study Plan For Sampling and Analysis Activities to Support Freon Replacement Method Study, December
1991. Copies of this study plan are available from the Sample Control Center (operated by DynCorp Viar), 300
North Lee Street, Alexandria, Virginia 22314, (703) 557-5040.


June 1993                                                                                   5

-------
Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease	


        •  expected oil and grease concentration levels
        •  geographic location
        •  accessibility of waste streams
        •  limited co-mingling of wastes
        •  willingness of facilities to participate
        •  cooperation and assistance of facility personnel.

        As the study progressed, 21 additional sites were included to expand the number of industrial
categories and waste types, as budget constraints would allow. Considerations for selecting additional
sites involved extending the range of oil and grease concentrations being studied, focusing on
categories with existing oil and grease effluent limitations and on categories with petroleum-based
waste types,  and including waste streams with known analytical interference problems.
        The Office of Water coordinated all facility contacts and planning for the sample collection
efforts. Facilities volunteering to participate were selected primarily from EPA Regions I, II, and III
to minimize the costs of travel and equipment transportation.
        Aqueous and solid/sludge waste samples were collected from a total of 39 industrial and
commercial facilities. These 39 facilities represent 24 industrial categories, 40 aqueous waste streams
and 28 solid/sludge waste sources.  A site summary is presented in Appendix A, Exhibit A-l, and
shows the facility types, industrial categories, and waste streams included in the study. Appendix A,
Exhibit A-2, presents additional information about the wastewater sources; it  identifies petroleum-
based  streams and groups the samples into one of four treatment categories. Samples identified as
having no treatment include raw process wastewaters. Primary treatment includes simple detention for
oil/water separation or solids removal, or physical/chemical treatment designed for something other
than oil removal.  Secondary oil/water separation includes systems such as dissolved air flotation,
dispersed gas flotation, and filtration intended for oil removal beyond simple  detention. Biological
treatment includes activated sludge and aerated lagoon systems.

2.3    Analytical Study Design

        Initially, the study focused on evaluation of six solvents,  including Freon 113, using
conventional separatory funnel extraction for aqueous samples and Soxhlet and sonication extraction
for solid samples, all followed by gravimetric determination. Interest in EPA's study was widespread,
however, and shortly after initiating the first phase of the study EPA was approached by several
manufacturers of alternative extraction devices and measurement techniques.  These manufacturers
agreed to analyze splits of the EPA samples by their techniques  and to provide the results of their
analyses to EPA at no cost to the Agency. The approaches to evaluation of each of the measurement
techniques are presented below.
                                                                                       June  1993

-------
          Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
 Separator/ Funnel Extraction of Aqueous Samples

        The performance of five alternative extraction solvents was compared with Freon 113 in
 actual sample matrices. The five solvents were:


        •   n-hexane and methyl tertiary butyl ether (MTBE) in an 80/20 mixture
        •   «-hexane alone
        •   DuPont 123 (2,2-dichloro-l,l,l-trifluoroethane)
        •   methylene chloride (dichloromethane)
        •   perchloroethylene (tetrachloroethene).

        Wastewater samples were extracted with each of these solvents and Freon 113 using the
 separatory funnel techniques described in Method 413.1.2 Since the densities of the solvents range
 from lighter than water to heavier than water, the specifics of the extraction procedures in Method
 413.1 were adjusted to explicitly deal with removal of each solvent from the separatory funnel and
 appropriate treatment for emulsions that might form.3
        Three aliquots of each sample were extracted with each solvent and were analyzed in a single
 laboratory only.  Although the initial plan was to have all samples analyzed in one laboratory to
 eliminate a potential source of differences, three laboratories were ultimately required to meet
 schedule, cost, and quality considerations.  Having multiple laboratories was  thought to be a negligible
 source of variability because all comparisons between solvents were performed on a single sample
 basis.
        A total of 40 triplicate aqueous sample sets were collected and sent to contract laboratories for
 analysis. Twenty-one triplicate sample sets were sent to Skinner and Sherman, Inc. in Waltham, MA,
 13 triplicate sample sets were sent to ETS Analytical Services  in Roanoke, VA and eight triplicate
 sample sets were sent to the Geochemical  and Environmental Research Group of Texas A&M
 University.

 Soxhfet and Sonication Extraction of Solid Samples

        Sonication was tested as an alternative to the Soxhlet extraction required by Method 9071 A.
 In addition, the performance of five alternative extraction solvents was compared with Freon 113  in
 actual sample matrices. The five alternative solvents tested were the same as those tested in aqueous
 samples using conventional separatory funnel techniques.
    2Method 9070 is essentially the same as Method 413.1 and therefore was not formally evaluated.


    3A total of five alternate versions of Method 413.1 were drafted for use by laboratories participating in this
study.  Copies of these methods are available from the Sample Control Center, 300 North Lee Street, Alexandria,
Virginia 22314, (703) 557-5040.


June  1993                                                                                     7

-------
Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
        Solid samples were extracted with each of the five alternative solvents and Freon 113 using
the Soxhlet extraction techniques described in Method 9071 A. Splits of the solid samples were also
analyzed at the same laboratory using all six solvents and sonication procedures. The specifics of the
extraction procedures in Method 9071A were adjusted to explicitly deal with the use of alternative
solvents and the use of sonication extraction techniques.4
        A total of 28 triplicate solid sample sets were collected and sent to contract laboratories for
analysis. Twelve triplicate sample sets were sent to Skinner and Sherman, Inc. in Waltham, MA, nine
triplicate sample sets were sent to ETS Analytical Services in Roanoke, VA and nine triplicate sample
sets were sent to the Geochemical and Environmental Research Group of Texas A&M University.

Solid Phase Extraction (SPE) of Aqueous Samples

        The performance of solid phase extraction (SPE) techniques was evaluated by the EPA's
Central Regional Laboratory (CRL) in Annapolis, MD and by two manufacturers of SPE devices. The
SPE techniques tested on aqueous samples have the advantage of using significantly less solvent than
conventional separatory funnel extraction techniques.
        EPA's CRL extracted aqueous samples with EnvirElute SPE columns (also known as SPE
cartridges) supplied by Varian Sample Preparation Products, using Freon 113 and all five solvents
listed above and gravimetric determination. Each of the samples sent to the EPA laboratory was
analyzed in triplicate. Due to the high solids content in most of the aqueous samples, the EPA CRL
was able to analyze only four of the eight sample sets they received.
        Varian Sample Preparation Products extracted 20 aqueous samples  with a newer version of the
SPE columns and a refined technique that allowed testing of samples containing higher concentrations
of suspended solids than the previous version tested by the EPA CRL. Varian tested Freon 113, n-
hexane, and the 80/20 hexane/MTBE mixture as solvents and determined the results gravimetrically.
Varian did not test methylene chloride or perchloroethylene as extraction solvents. Each of the
samples sent to Varian was analyzed in triplicate.
        The 3M Corporation extracted 28 aqueous samples, using Empore  SPE disks, with the
following five solvents: Freon 113, methylene chloride, n-hexane, 100% MTBE,  and
perchloroethylene. The results were determined gravimetrically. The 3M Corporation did not test the
80/20 mixture of n-hexane and MTBE. Splits of each sample were analyzed using 47 mm SPE disks
and 90 mm SPE disks. Each of these sample splits was analyzed  in triplicate. The 90 mm SPE disks
required the use of a full 1-liter sample volume, which is consistent with traditional oil and grease
measurement techniques and with all other techniques evaluated in this study except the 47 mm SPE
disks and the infrared technique described below. Both of these techniques utilized 250 Ml  sample
volumes.
        All samples extracted with SPE  devices were splits of samples analyzed by separatory funnel
extraction.
    4A total of eleven alternate versions of Method 9071A were drafted for use by laboratories participating in this
study.  A separate version was prepared for Soxhlet extraction of each of the five alternative solvents.  Separate
versions were also prepared for sonication extraction of each alternate solvent and Freon 113. Copies of these
methods are available from the Sample Control Center, 300 North Lee Street, Alexandria, Virginia 22314, (703)
557-5040.

8                                                                                    June 1993

-------
          Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
 Non-Dispersive Infrared Analysis of Aqueous Samples

        Horiba Instruments Inc. analyzed 36 aqueous samples by a non-dispersive infrared (NDIR)
 analyzer technique using S-316 (a chlorofluorocarbon also known as Flon and specifically developed
 for the Horiba analyzer) as a solvent. An advantage of this infrared technique is that it offers lower
 levels of detection than those afforded by conventional  separatory funnel extraction followed by
 gravimetric determination. As  with the SPE analyses, the Horiba results were compared statistically to
 the results produced on splits of the same samples with separatory funnel and Freon  113  extraction.
June  1993

-------

-------
                                                                                 SECTION  3
                                                                         FIELD  SAMPLING
        Sample collection and handling efforts were carried out by Office of Water (OW) staff,
 contractors, and facility staff. Activities included:

        •  communications and coordination with representatives of selected sampling sites and
           assigned laboratories
        •  logistics planning
        •  preparation of field equipment, sample containers, shipping containers, and documentation
        •  collection, handling, and transport of samples
        •  preparation of sample collection documentation
        •  follow-up communications with receiving laboratories for sample tracking.

        For safety purposes,  arrangements were made in advance to have plant personnel accompany
 and assist U.S. Environmental Protection Agency (EPA) and contractor representatives while on site.
 To minimize sampling costs where possible, EPA also asked some of the selected facilities to have
 plant personnel collect samples. In those cases, EPA sent prepackaged sampling kits directly to the
 sites with instructions for use and shipment to  assigned laboratories.
        Since the primary purpose of this data gathering effort was to investigate the use of alternative
 oil and grease extraction solvents with real world samples, and not to characterize selected
 wastewaters and solid wastes for regulation development, short-term grab sampling of the selected
 sources was deemed sufficient to meet the requirements of the study.
        Sampled material was mixed in a collection vessel, and transferred by siphoning or scooping
 into 1-liter, wide-mouth, clear glass bottles with PTFE-lined caps. (Samples sent to 3M for extraction
 with the 47 mm disks and to  Horiba for infrared analysis were collected in 250 Ml bottles.) Aqueous
 samples were preserved on-site with HC1 (1:1) to Ph less than two, and all aqueous and solid/sludge
 samples were cooled to between 0° and 4°C during storage and shipment. Each sample bottle was
 labeled with a unique EPA sample number and identifying information, including bottle number,
 source location, collection date, and preservatives used. EPA sample numbers were the primary
 method of identifying and tracking samples.  These numbers were pre-assigned and recorded to ensure
 proper control over samples.  EPA traffic reports were completed for each site or sampling episode,
 and accompanied each shipment to the appropriate  laboratories. Copies of these reports were used by
 EPA contractor and field personnel for tracking purposes.
       Information regarding site-specific sampling activities was recorded in an on-site log for each
 sample location, and included EPA sample numbers, collection date and time, description of sample
 location, collection procedure, sample Ph and temperature, and preservatives used. Field personnel
 double-checked all labels, traffic reports, and log entries to ensure accuracy and consistency.
June 1993                                                                                   //

-------

-------
                                                                                SECTION 4
                              DATA VALIDATION AND STATISTICAL ANALYSIS
        This section describes data validation and statistical analysis. Data validation was
straightforward, as described in subsection 4.1 below.  Statistical analysis was complicated by the
non-uniform nature of the error distribution of the data. The ultimate measure of agreement between
alternative solvents  or techniques  and Freon 113 was the "normalized root mean square deviation"
(RMSD), as described in subsection 4.2 below. An indicator of the  amount of oil and grease extracted
by a given solvent relative to the amount extracted by Freon 113 is  the "solvent-to-Freon ratio" which
is also described in 4.2. When this ratio is averaged across samples, those with greater extraction of
oil and grease (i.e., ratios of more than one) will cancel those with lesser extraction of oil and grease
(i.e.,  ratios  of less than one), yielding an average ratio close to  one. Therefore, the average solvent-
to-Freon ratio cannot  be relied upon as a measure of agreement between the alternative solvent and
Freon 113. The solvent-to-Freon ratio is presented before the RMSD in Section 4.2 because the data
are not log-transformed to construct the solvent-to-Freon ratio, but are log-transformed to construct
the RMSD.

4.1    Data  Validation

        All data from  Phase I of the study were submitted to the U.S. Environmental Protection
Agency (EPA) by May 1993. The contract laboratories and other study participants submitted data in
computer-readable or  hardcopy formats. The computer-readable result files were verified against the
hardcopy data,  then loaded into the study database. Results were entered into the  study database
manually if no computer-readable data were provided. Hardcopy data, including all calculations,
submitted by the three contract laboratories (for separately funnel extraction of aqueous samples and
Soxhlet and  sonication extraction of solid samples), were verified from the bench sheets provided.
        A number of samples containing low concentrations of oil and grease yielded negative results
or results below the nominal detection limit of Method 413.1 for aqueous samples (5 mg/L) or the
equivalent detection limit in solid samples (approximately 1,000 mg/kg). The negative numbers
resulted from either the subtraction of blanks (as required by the method) containing concentrations
larger than those in the associated samples  or from measurement error in the tare weights of the
sample bottles (which weighed approximately 100 grams whereas the oil and grease residue was
measured in milligrams). Negative results were found almost exclusively in aqueous samples and were
primarily traceable to  one of the contract laboratories performing the analyses. Treatment of negative
values and values below the method detection limit is discussed  in Section 4.2.

4.2    Statistical Analysis

       Preliminary statistical analyses of gravimetric results from the separatory  funnel, Soxhlet, and
sonication techniques were presented at the Pittsburgh Conference on Analytical Chemistry and
Applied Spectroscopy  held in Atlanta, Georgia on March 10, 1993,  and at the Oil and Grease

June  1993                                                                                  13

-------
Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
Workshop held by the Office of Water (OW) in Norfolk, VA on May 4, 1993. This report includes a
revised statistical analysis of those results as well as a statistical analysis of the results generated using
solid phase extraction (SPE) and infrared measurement techniques. A table containing all results for
the study in unreduced form is provided in Appendix B.

Data Stratification

       Initial statistical analyses of all samples within each extraction technique yielded no solvents
that were within the respective RMSD Acceptance Limits. Further stratification of the study database
was undertaken to determine whether results equivalent to Freon 113 could be achieved by testing
subclasses of the data. Stratification by industry type was attempted, but resulted in too many small
data sets. Because it was expected that oil and grease of biological (animal or vegetable) origin might
behave differently than oil and grease of mineral origin (petroleum), the data were stratified into
"petroleum" and "non-petroleum" samples. (If necessary, personnel from the sampled facilities were
questioned as to the origin of oil and grease in their effluents or wastes). For  example, the effluent
from a meat packing plant was categorized as non-petroleum, whereas the effluent from a refinery
was categorized as petroleum.

Solvent-to-Freon  113 Ratio

       A solvent-to-Freon 113 ratio (solvent-Freon ratio) was computed to allow comparison of the
average amount of oil and grease extracted by various solvents and measurement techniques with the
amount extracted by the approved techniques using Freon 113.
       The solvent-Freon ratio for each sample was formed by dividing the mean of the triplicate
results produced with the  alternative solvent or technique by the mean of the triplicate result produced
with the approved technique using Freon 113. The mean, standard deviation (SD), relative standard
deviation (RSD), and the median of the solvent-Freon ratios were calculated across all samples in
each of the eight data sets representing an alternative solvent or technique (Exhibits 3 through 10).
These results are discussed in Section 5.
       Because averaging gives no indication of the variability of the data, the solvent-Freon ratio is
a less powerful measure of the agreement between an alternative solvent (or technique) and Freon 113
than the normalized RMSD described below. This normalized RMSD was used as the main criterion
of similarity. Median, mean,  and standard deviation values of the solvent-Freon ratio were used as an
aid in describing the distribution of the data.

Logarithmic Data Transformation

       The triplicate analysis of each sample allows the error associated with each measurement to be
modeled as  a function of concentration. Analytical data normally have a proportional error structure
over the calibration range of the measuring technique (i.e., as the parameter being measured
increases, the standard deviation will increase in proportion to the measurement). This proportional
error structure normally results in a constant relative standard deviation (RSD; coefficient of
variation.)
 14                                                                                   June 1993

-------
          Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease


        To determine the nature of the error in this study, the RSD was plotted as a function of
concentration. Exhibit 2 shows this plot for aqueous samples. Similar results occurred with
solid/sludge samples. As can be seen from Exhibit 2, the plot has a proportional error structure above
a concentration of approximately 35  mg/L. Below 35 mg/L, however, the RSD rises rapidly and
asymptotically approaches a very large value at the detection limit of the method (5 mg/L).
        The data were examined by ANOVA statistical techniques. The heteroscedasticity (non-
uniform standard deviations) of these data, however, violates the statistical requirements  for use of
ANOVA techniques. The heteroscedasticity was overcome by modeling standard deviation as a
function of concentration, as discussed in Appendix C, and then subjecting the data to an appropriate
variance-stabilizing transformation according to the equation:

        z  = log (x + c) - log c

where

        x  is the concentration (in mg/L or mg/kg), and

        c  is a constant.

        The constant (c) was used to prevent samples at low concentrations from having  exaggerated
influence and to allow negative values to be transformed to a logarithmic scale. The constant (c) was
set to 100 mg/L for aqueous samples and 10,000 mg/kg for solid samples. The transformed data (z)
were then subjected to ANOVA.
        To assure that the results below the detection limit were not unduly influencing the
comparison between solvents, the data were treated in three ways before transformation:  (1) the
results were tested "as is" (i.e., without alteration), (2) all results below the nominal detection limit
were set to the detection limit, and (3) results were eliminated if they were below the nominal
detection limit using the currently approved extraction technique (e.g., separatory funnel  extraction
with Freon 113 or Soxhlet extraction with Freon 113).  After transforming the data using the equation
cited above, all three treatments yielded nearly identical results: the solvents that produced results
closest to  Freon 113 were not changed by  the three data treatments.  This conclusion substantiates the
belief that the transformation diminishes the effect of the results below and near the nominal detection
limit. After  reaching this conclusion, all data were treated with the second option for the remainder of
the study. This is consistent with the EPA Engineering and Analysis Division's standard  reporting of
results that are below method detection limits.

Root Mean Square Deviation (RMSD)

        As was noted above, the primary measure of similarity used to compare Freon 113 with each
of the other solvents and techniques was the RMSD of the alternative results for each sample around
the Freon 113 results. For each technique, the RMSD represented the standard deviation of  the
differences between the alternative solvent-determined concentrations for each sample and the Freon
113-determined concentrations using the appropriate approved technique. A smaller RMSD indicated
better agreement with Freon  113.

June 1993                                                                                   15

-------
Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease


                                         Exhibit 2.
                       Relative Percent Deviation vs.  Concentration
RPD
2OO
1 9O

18O

17O

160

150

140

130

120

110

100

 90

 8 O

 70

 6O

 5O

 4O

 3O

 20

 10

  0
<9

                                          A quaou 3 S amplas
                    '00
                 ^00,0
          1 O O
 o
I
 o
                                   O o
    0    1OO   200  3OO  40O   5OO   6OO  7OO   BOO   90O   1OOO  1100  12OO 130O  14OO  150O 1600 170O
                                                MEAN
 16
                                                                                  June 1993

-------
          Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
        In performing the statistical analyses, the data were transformed using the equation above, and
the triplicate concentration results for each sample and solvent or technique were averaged. The
RMSD for each alternative procedure was calculated by taking the difference of the Freon  113
averages from those of the alternative procedure, squaring the differences, averaging these  across all
samples, and then taking the square root of those averages. (The details of this calculation are
presented in Appendix C.)

        The RMSD values were normalized by dividing each RMSD by the square root of the
expected mean squared deviation based on the replicate variability (see Appendix C for details). To
determine the significance of the RMSD results (where sufficient data existed), a 95 percent
Acceptance Limit was calculated from each of the eight data sets (aqueous, Soxhlet, Sonication,
Horiba, EPA CRL SPE, Varian SPE, 3M 47 mm SPE, and 3M 90 mm SPE)  for the three  sample
strata: (1) all samples,  (2) petroleum-based samples, and (3) non-petroleum based samples.  In other
words, the Acceptance Limit is the 95th percentile of the normalized RMSD that would be  observed
if the two methods under comparison were exactly equivalent, (i.e., if Freon 113 were compared to
itself). Solvents or techniques with RMSDs smaller than the associated Acceptance Limit are  not
statistically different from Freon 113 extraction with the approved technique. Normalized RMSD
results and Acceptance Limits  for each of the alternative solvent and measurement techniques
evaluated are presented in Exhibits 3 through 10.
        The RMSD measures variations both above and within the amount of oil and grease extracted
by Freon 113. This is important because the alternative solvent might extract less or more oil and
grease than Freon 113, depending on the sample. Having the same average results across many
samples is a desirable but by no means sufficient test of equivalence of the extraction performance of
the alternative solvent. Average results for a solvent might be close to those obtained with Freon 113,
but the results for a particular  sample may be quite disparate.  The RMSD is smallest, and is therefore
most likely to be within the Acceptance Limit when the results for a solvent are both accurate and
precise when compared to results obtained with Freon 113.
June 1993                                                                                   77

-------

-------
                                                                                SECTION 5
                                                                              DISCUSSION
        The statistical results presented in Exhibits 3 through 10 are discussed in Sections 5.1  through
5.4 below. As explained in Section 4, the root mean square deviation (RMSD) was used as the main
criterion of equivalence between the results obtained with established techniques (Freon 113 with
separatory funnel or Soxhlet extraction) and all other solvents and techniques. Other descriptive
statistics (median, mean, standard deviation [SD], and relative standard deviation [RSD] of solvent-
Freon ratios) are provided in this report only to demonstrate the distribution of the data.
        In these tests, some solvents and techniques extracted more oil and grease than Freon  113.
Although achieving higher results than the Freon 113 methods might be seen as a method
"improvement", such enhanced recovery of an operationally-defined parameter presents significant
problems for the implementation of the "improved" method under the National Pollutant Discharge
Elimination System (NPDES), as thousands of NPDES permits contain oil and grease limits based on
the present methods. Therefore, the objective  of this study  was to find a solvent or technique that
yields oil and grease results equivalent to rather than better than those obtained with Freon 113.
        Exhibits 3 through 10 are arrayed to provide a comparison of each alternative solvent  or
technique tested, for the entire group of samples analyzed,  for petroleum-based samples, and for non-
petroleum samples.  Solvents or techniques that have a normalized RMSD within the Acceptance Limit
shown for the established method (separatory funnel or Soxhlet extraction with Freon) yield results
that are not statistically different from Freon 113.

5.1    Separatory Funnel Extraction of Aqueous  Samples

        Results of the statistical analysis of data for separatory funnel extraction and gravimetric
determination of oil and grease in aqueous samples are presented in Exhibit 3. The results are based
on analysis of 25 petroleum-based samples and 13 non-petroleum samples for a total of 38 aqueous
samples. (Not all of the 40 aqueous samples taken were successfully analyzed.)
        Exhibit 3 shows that when all  samples were examined as a group, none of the solvents tested
yielded results within the Acceptance Limit. When non-petroleum and petroleum samples were
examined separately, however, n-hexane and perchloroethylene were  both within the Acceptance
Limit in the non-petroleum group.
        Mean solvent-Freon ratios for the separatory funnel extractions ranged from 1.02 (for
petroleum-based samples extracted with n-hexane) to 2.61 (for non-petroleum extracted with DuPont
123).  Relative standard deviations of the solvent-Freon ratios ranged from 51% (for petroleum-based
samples extracted with methylene chloride) to  230% (for non-petroleum samples extracted with
DuPont 123). Median solvent-Freon ratios were in the range of 0.81 to 1.38.
June  1993                                                                                  19

-------
Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease	


       The data in Exhibit 3 suggest that although some alternative solvents were capable of
producing average and/or median results similar to Freon 113 in each category of samples analyzed,
the variability of these data was extremely high. As a result, and based on the RMSD, the only
alternative solvents  that yielded results equivalent to Freon 113 were n-hexane and perchloroethylene,
and the equivalency of these solvents was demonstrated for non-petroleum samples only.

5.2   Soxhlet and Sonication  Extraction  of Solid Samples

       Results of the statistical analysis of data for 28 solid samples are presented in Exhibits 4 and
5. Exhibit 4 presents the results of data generated using the established Soxhlet extraction and
gravimetric determination with six solvents; Exhibit 5 presents the results generated using the
alternative sonication and gravimetric determination with the same six solvents.
       Exhibit 4 indicates that relatively good agreement between median solvent-Freon ratios was
obtained using alternative solvents and Soxhlet extraction of solid samples. Means of solvent-Freon
ratios ranged from 0.99 to 2.14, and RSDs ranged from 22% to  160%. The results in Exhibit 4
further indicated that none of the alternative solvents was within  the Acceptance Limit when all
samples were evaluated together. Similarly, none of the solvents  was within the Acceptance Limit
when only non-petroleum samples were examined. Two of the solvents, however, were within the
Acceptance Limit when only petroleum-based samples were evaluated (w-hexane and 80/20.)
       In Exhibit 5, all six solvents (including Freon 113) used  with sonication extraction of solid
samples were compared to Freon 113 using Soxhlet extraction. This  comparison was made because
the purpose of the study was to compare the performance of alternative solvents and techniques with
currently approved  solvents and techniques. As noted earlier, the Agency method for determination of
oil and grease in solids (Method 9071A) specifies  the Soxhlet extraction using Freon 113 as a solvent.
       Exhibit 5 shows poor agreement between the mean and median results obtained with Freon
113 using the  Soxhlet extraction and with all solvents using sonication. Further, variability (standard
deviation and relative standard deviation)  of these  data was high.  (Exhibit 5 shows mean solvent-
Freon ratios that range from 0.49 to 3.69, with RSDs of 37% to 370% and median solvent-Freon
ratios from .43 to .81.) Aside from methylene chloride, all solvents tested with sonication yielded
mean and median solvent-Freon ratios within those obtained using Soxhlet extraction with Freon  113.
As a result of the high variability between the sonication data and the Soxhlet data with Freon 113,
only one RMSD value was observed within the Acceptance Limit in Exhibit 5. That value was for
perchloroethylene when only non-petroleum samples were examined.

5.3   Solid Phase Extraction  (SPE)  of  Aqueous Samples

       Exhibits 6 through 9 present the results of the statistical  analysis of data generated from
aqueous samples using solid phase extraction (SPE) and gravimetric  determination. The format of
these tables is the same as that of Exhibits 3 through 5. As with  the results of sonication extraction of
solid samples, all results generated using  SPE techniques were compared to the performance of
approved test methods (in this case, Freon 113 using separatory  funnel techniques).  Results of
alternative techniques were not compared with  each other, nor were they compared to the
performance of Freon 113 with the  alternative technique.


20                                                                                  June  1993

-------
          Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
        Exhibit 6 summarizes the statistical calculations of data generated by 3M using 90 mm SPE
disks. Exhibit 7 presents the  results generated by 3M using 47 mm SPE disks. Nineteen of the 25
aqueous/petroleum and nine of the 13 aqueous non-petroleum samples in the study were tested using
each type of disk.
        Mean solvent-Freon ratios in Exhibits 6 and 7 for the SPE data using alternative solvents were
all above 1.0 (they ranged from  1.09 to 2.78 for 90 mm disks and from 1.19 to 3.5 for 47 mm
disks). The ratios between Freon 113 with SPE and Freon 113 with separatory funnel extraction were
.94 and 1.11 for the 90 mm and the 47 mm disks,  respectively. Variability with the SPE disks was
generally high, with RSDs ranging  from 57 to 110% for the 90 mm disks and from 60 to  130% for
the 47 mm disks. Median solvent-Freon ratios using the 90 mm disks ranged from 0.94 to  1.83. The
highest mean results were obtained with methylene chloride and 100% MTBE.  Median solvent-Freon
ratios for alternative solvents using the 47 mm disks were higher than for the 90 mm SPE disks,
ranging from 1.26 to 3.65.
        The RMSD values in Exhibits 6 and 7 further show that the use of separatory funnel
extraction with Freon 113 and the use of either 47  mm or 90 mm disks with alternative solvents do
not produce equivalent results. The only RMSD value in these tables within the Acceptance Limit is
for Freon 113 using the 90 mm disks when non-petroleum samples were examined alone.
        Exhibit 8 presents the results obtained by the EPA Central Regional Laboratory (CRL) using
an early version of the Varian SPE column.  Due to technical difficulties (primarily clogging of the
columns due to high percent  solids in the samples)  results for only two petroleum and two non-
petroleum samples were obtained. Mean and median solvent-Freon ratios were less than 1.0, and
RSDs were lower than for other techniques tested.  Normalized RMSD results indicate that all solvents
tested were equivalent to separatory funnel extraction with Freon 113. A review of the individual
results for the samples tested, however, shows that oil and grease concentrations in three of four
samples is near or below the  detection limit.
        The setting of results below the detection limit to 5 mg/L was considered as a possible reason
why the CRL  SPE data showed all solvents to be equivalent to Freon 113. Tests with the three data
treatments described in the section on  "Logarithmic Data Transformation" in section 4.2, however,
yielded equivalent results, indicating that this was not the sole reason. Because these concentrations
are low, the addition of the constant in the log-transformation reduces the effect of the differences
between solvents. In addition, the results are fairly precise, with RSDs ranging from 19 to 55 percent.
This combination of low concentrations and precise data makes the RMSDs small and consistent, so
that differences between solvents are not discernable.  Although it would be possible to reduce or
eliminate the constant from the equation for transforming the CRL SPE data, the net result  would be
that the conclusions would be based on a single sample.
        Given all of  the above, the final conclusion concerning the CRL SPE data is that there are
insufficient data to provide a  rigorous comparison between solvents.
        Exhibit 9 summarizes Varian's  data for fifteen of the 25 petroleum samples and five of the 13
non-petroleum samples tested using a later version of the their SPE column. As noted earlier, only
Freon 113 and two alternative solvents  (n-hexane and the 80/20 mixture) were evaluated by Varian.
Mean solvent-Freon  ratios ranged from 0.93 to 1.13, and the median ratios ranged from 0.93 to 1.19.
Variability,  as represented by the RSD  of the solvent-Freon ratio, was relatively low (21%  to 49%.)
Neither n-hexane nor the 80/20 mixture yielded RMSDs within the Acceptance Limit for all samples
June 1993                                                                                   21

-------
Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
taken together, or for the petroleum subset. Both n-hexane and the 80/20 mixture had RMSDs within
the Acceptance Limit in the non-petroleum category. This result must be viewed with caution due to
the small number of samples involved (n = 5).

5.4   Non-Dispersive Infrared Analysis of Aqueous Samples

       The statistical results obtained with data generated by Horiba Instruments using an infrared
analyzer are presented in Exhibit 10. These results represent 23 of the 25 petroleum-based aqueous
samples and all 13  of the non-petroleum aqueous samples in Phase I of the study. The mean solvent-
Freon ratio found using the Horiba method was 1.2 to 2.3 times the result for separatory funnel
extraction using Freon  113. Variability was high (58 to 98% RSD.) The normalized RMSDs for the
Horiba results were much higher than the Acceptance Limits in all three categories analyzed,
indicating that results were not equivalent to Freon 113.

5.5   Graphical Presentation of  RMSD Versus Acceptance Limit Results

       To give the reader a better understanding of the relative performance of all of the alternative
solvents and techniques evaluated, the RMSD and Acceptance Limit data are presented graphically in
Exhibit 1, which was presented in the Executive Summary of this report, and in greater detail in
Exhibits 11 through 15.
       In Exhibits 11 through 15, the RMSD  for a particular  solvent or technique is represented by a
solid or hollow circle, and Acceptance Limits are indicated by horizontal lines.  Where these RMSD
circles fall within the relevant Acceptance Limit line, that solvent or technique is equivalent to
separatory runnel or  Soxhlet extraction with Freon 113, as appropriate.  Where no solvents or
techniques yield results equivalent to Freon 113, no circles are shown within the Acceptance Limit
line.

5.6   Graphical Presentation of  the Solvent-Freon  Ratios

       Exhibit 16  summarizes all of the solvent-Freon ratios on one graph.  In this graph, the mean
solvent-Freon ratio (computed prior to log-transformation of the data) is plotted on a logarithmic scale
so that amounts of oil and grease greater or less than the amount extracted by Freon 113 are
equidistant from 1.00.
       This graph shows that the solvent-Freon ratio can range from  approximately 0.3 to 2.6,
depending on the solvent, technique, and kind of sample being extracted. Of interest in this graph is
the influence  of the solvent or technique on the average amount of material extracted. For example,
Soxhlet extraction with the alternative solvents seems to extract somewhat more oil and grease than
the reference  Soxhlet extraction with Freon 113, whereas less oil and  grease is extracted with
sonication rather than with Soxhlet using Freon 113 unless methylene chloride is used in the
sonication extraction. It must be remembered that these ratios  represent the overage amount of
material extracted,  whereas the RMSD represents the deviation from the amount extracted by Freon
113 on an individual sample basis. Therefore,  although these averages are interesting, they cannot be
relied upon as the final criterion for equivalence.


22                                                                                 June 1993

-------
          Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
        The use of Freon 113 as the extracting solvent in these alternative techniques allowed the
 variables of the solvent and the technique to be separated. The amount of oil and grease extracted by
 Freon 113 using cartridges and 90 mm disks was, on average, less than the amount extracted using
 the reference separatory funnel method whereas the average amount of material extracted by the 47
 mm disks was greater. For the cartridges and the 90 mm disk, this lesser average amount extracted by
 Freon 113 was compensated when an alternative solvent such as MTBE, 80/20, or perchloroethylene
 was used. (Due to large standard deviations  in the results, however, the average amount extracted
 may not be statistically significant.)
        The variables of solvent versus technique cannot be separated for Flon-316 and NDIR because
 Freon 113 was not tested with the NDIR technique. Therefore it is not known whether the larger
 amount of oil and  grease indicated by the Flon/NDIR technique results from the use of Flon-316 or
 results from the way in which the NDIR was calibrated.
June 1993                                                                                  23

-------
Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
                                             Exhibit 3.
    Summary Statistics For Alternative Solvents in the Determination of Oil and Grease
                    Aqueous Waste Stream,  Separatory Funnel Extraction
           ' Acceptance Limit
: Value Within Acceptance Limit
All Samples (N=38)
Solvent
Freon
Hexane
MeCl2
Perchlor
DuPont
80/20
Mean
1 00
1 17
1 57
1 65
1.85
1.38
SD
-
1.26
1 84
0.99
3 66
2.17
RSD
--
110
120
60
200
160
Median
1 00
0.87
1.00
1.37
1.08
0.94
RMSD
1.4"
1.7
3.3
1 7
4.5
3.7
Non-Petroleum (N=I3)
Solvent
Freon
Hexane
MeCl2
Perchlor
DuPont
80/20
Mean
1 00
1.45
2.33
1 65
2.61
200
SD
--
1.89
3.00
1.01
6.00
3.62
RSD
--
130
130
61
230
180
Median
1.00
0.94
1.32
1.34
1.03
0.98
RMSD
1.8"
1.3"
3.2
1.1"
4.7
4.1
Petroleum (N=25)
Solvent
Freon
Hexane
MeCl2
Perchlor
DuPont
80/20
Mean
1.00
1.02
1 20
1.65
1.47
1.07
SD
-
0.77
0.60
1.00
1.61
0.74
RSD
-
75
51
61
110
69
Median
1.00
0.81
1.00
1.38
1.15
0.92
RMSD
1.5"
2.6
3.6
2.9
3.5
2.0
          Mean = Mean of Solvent to Freon Ratios
          SD = Standard Deviations of Solvent to Freon Ratios
          RSD = 100 x SD/Mean
          Median = Median of Solvent to Freon Ratios
          RMSD = Normalized Root Mean Square Deviation of Sample x Solvent Means
 24
                                                                                          June 1993

-------
          Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
                                              Exhibit 4.
     Summary Statistics For Alternative Solvents in the Determination of Oil and Grease
                             Solid Waste Stream,  Soxhlet Extraction
               * Acceptance Limit
All Samples (N=28)
Solvent
Freon
Hexane
MeCI2
Perchlor
DuPont
80/20
Mean
1.00
1 18
1.63
1 75
1.37
1.29
SD
--
1.07
1 56
240
1 03
1 31
RSD
-
91
95
140
75
100
Median
1.00
0.95
1.06
1 20
1.04
1.01
RMSD
1.5'
22
2 9
3 5
2 5
2.4
Non-Petroleum (N=ll)
Solvent
Freon
Hexane
MeCl2
Perchlor
DuPont
80/20
Mean
1.00
1 48
2.05
2.14
1.52
1.66
SD
-
1.69
2.27
3.44
1.52
2.07
RSD
-
110
110
160
100
120
Median
1.00
0.95
1.11
1.22
0.94
1.03
RMSD
1.9'
2.6
3.1
3.5
2.8
2.8
Petroleum (N=n>
Solvent
Freon
Hexane
MeCl2
Perchlor
DuPont
80/20
Mean
1.00
0,99
1.36
1.50
1.28
1.06
SD
-
0.23
0.83
1.46
0.56
0.23
RSD
-
23
61
98
44
22
Median
1.00
0.96
1.04
1.18
1.08
1.00
RMSD
1.7'
1.1"
2.5
3.5
2.0
1.1"
** Value Within Acceptance Limit
         Mean = Mean of Solvent to Freon Ratios
         SD = Standard Deviations of Solvent to Freon Ratios
         RSD = 100 x SD/Mean
         Median = Median of Solvent to Freon Ratios
         RMSD = Normalized Root Mean Square Deviation of Sample x Solvent Means
June 1993
                                                               25

-------
Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
                                             Exhibit  5.
   Summary Statistics For Alternative Techniques in the Determination of Oil and Grease
                           Solid Waste Stream, Sonication Extraction
               * Acceptance Limit
** Value Within Acceptance Limit
All Samples (N=27)
Solvent
Soxhlet Freon
Hexane
MeCI2
Perchlor
DuPont
80/20
Freon
Mean
1.00
0.50
2.51
0.82
0.72
061
0.62
SD
-
032
9.25
0.57
0.55
0.61
0.42
RSD
-
65
370
69
77
99
68
Median
1.00
0.43
057
0.73
0.52
0.50
0.50
RMSD
1.5"
3.3
3.8
2.0
2.6
3.4
2.4
Non-Petroleum (N=iO)
Solvent
Soxhlet Freon
Hexane
MeCl2
Perchlor
DuPont
80/20
Freon
Mean
1.00
0.49
0.63
0.89
0.64
0.53
0.58
SD
--
0.34
0.38
0.33
0.34
0.34
0.31
RSD
--
70
60
37
53
64
53
Median
1.00
0.48
0.62
0.81
0.70
0.56
0.54
RMSD
1.9'
3.1
2.6
1.3"
2.5
3.1
2.5
Petroleum (N= 17)
Solvent
Soxhlet Freon
Hexane
MeCl2
Perchlor
DuPont
80/20
Freon
Mean
1.00
0.50
3.69
0.79
0.76
0.66
0.64
SD
-
0.33
11.77
0.68
0.66
0.73
0.49
RSD
-
65
320
86
86
110
76
Median
1.00
0.43
0.57
0.70
0.49
0.47
0.48
RMSD
1.7"
3.5
4.6
2.5
2.7
3.7
2.4
         Mean = Mean of Solvent to Freon Ratios
         SD = Standard Deviations of Solvent to Freon Ratios
         RSD = 100 x SD/Mean
         Median = Median of Solvent to Freon Ratios
         RMSD =  Normalized Root Mean Square Deviation of Sample x Solvent Means
26
                                                       June 1993

-------
          Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
                                              Exhibit 6.
    Summary Statistics For Alternative Techniques in the Determination of Oil and Grease
                  Aqueous Waste Stream, 90 mm Solid Phase Extraction Disk
            * Acceptance Limit
1 Value Within Acceptance Limit
           Mean = Mean of Solvent to Freon Ratios
           SD = Standard Deviations of Solvent to Freon Ratios
           RSD = 100 x SD/Mean
           Median = Median of Solvent to Freon Ratios
           RMSD = Normalized Root Mean Square Deviation of Sample x Solvent Means
All Samples (N=28)
Solvent
Sep. Funnel Freon
Hexane
MeCl2
Perchlor
MTBE
Freon
Mean
1.00
1 15
1.95
1 26
2.71
0.93
SD
--
1 03
1 75
1 01
2 81
062
RSD
-
90
90
80
100
66
Median
1.00
0.99
1.26
1.11
1.62
0.94
RMSD
1.5'
6.0
7.1
5.8
7.9
5.0
Non-Petroleum (N=9)
Solvent
Sep. Funnel Freon
Hexane
MeCl2
Perchlor
MTBE
Freon
Mean
1.00
1.09
2.27
1.44
2.57
0.94
SD
-
068
1.71
0.81
209
0.35
RSD
-
63
76
57
81
38
Median
1.00
1.00
1.83
1.36
1.67
1.00
RMSD
2.0'
3.2
6.3
3.7
5.4
1.3"
Petroleum (N-19)
Solvent
Sep. Funnel Freon
Hexane
MeCl2
Perchlor
MTBE
Freon
Mean
1.00
1.18
1.80
1.19
2.78
0.93
SD
-
1.18
1.80
1.08
3.15
0.70
RSD
—
100
100
91
110
76
Median
1.00
0.94
1 16
0.99
1.58
0.87
RMSD
1.7*
7.3
7.6
6.8
9.2
6.3
June 1993
                                                                27

-------
Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
                                             Exhibit 7.
   Summary Statistics For Alternative Techniques in the Determination of Oil and  Grease
                 Aqueous Waste Stream, 47 mm Solid Phase Extraction Disk
           * Acceptance Limit
** Value Within Acceptance Limit
          Mean = Mean of Solvent to Freon Ratios
          SD = Standard Deviations of Solvent to Freon Ratios
          RSD = 100 x SD/Mean
          Median = Median of Solvent to Freon Ratios
          RMSD = Normalized Root Mean Square Deviation of Sample x Solvent Means
All Samples (N=28)
Solvent
Sep Funnel Freon
Hexane
MeCl2
Perchlor
MTBE
Freon
Mean
1 00
1 81
244
205
3.27
1.70
SD
--
2.00
2.50
2.36
3.82
1.75
RSD
--
110
100
110
120
100
Median
1.00
1 28
1.46
1.32
1.75
1 24
RMSD
1.5"
8.0
8.8
6.6
9.2
5.1
Non-Petroleum (N=9)
Solvent
Sep. Funnel Freon
Hexane
MeCl2
Perchlor
MTBE
Freon
Mean
1.00
1.19
2.59
1.64
2.78
1.11
SD
--
0.98
2.13
0.99
2.26
0.70
RSD
--
82
82
60
81
63
Median
1.00
1.31
2.94
1.44
3.65
1.06
RMSD
2.0"
13.0
14.0
3.0
14.0
3.7
Petroleum (N=19)
Solvent
Sep. Funnel Freon
Hexane
MeCl2
Perchlor
MTBE
Freon
Mean
1.00
2.11
2.37
2.22
3.50
1.93
SD
-
2.30
2.71
2.72
4.40
1.99
RSD
-
110
110
120
130
100
Median
1.00
1.26
1.44
1.30
1.68
1.24
RMSD
1.7"
7.7
8.5
8.5
9.5
6.6
 28
                                                                                          June 1993

-------
          Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
                                              Exhibit 8.
   Summary  Statistics For Alternative Techniques in the Determination of Oil and Grease
                       Aqueous Waste Stream, SPE Column (old version)
All Samples (N=4)
Solvent
Sep. Funnel Freon
Hexane
MeCl2
Perchlor
DuPont
80/20
Freon
Mean
1.00
075
0.84
0.84
071
0.85
0.69
SD

020
0.16
0.47
0.22
0 16
0.25
RSD

26
19
55
31
19
36
Median
1.00
0.74
0.77
0.62
067
0.80
065
RMSD
2.4'
07"
03"
1 1"
1.0"
0.3"
1 2"
           * Acceptance Limit        ** Value Within Acceptance Limit

          Due to the small number of samples, these results should be interpreted with caution

          Mean = Mean of Solvent to Freon Ratios
          SD = Standard Deviations of Solvent to Freon Ratios
          RSD = 100 x SD/Mean
          Median = Median of Solvent to Freon Ratios
          RMSD = Normalized Root Mean Square Deviation of Sample x Solvent Means
June 1993
29

-------
Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
                                            Exhibit 9.
   Summary Statistics For Alternative Techniques in the Determination of Oil  and Grease
                     Aqueous Waste Streams, SPE Column (new version)
           ; Acceptance Limit
** Value Within Acceptance Limit
          Mean = Mean of Solvent to Freon Ratios
          SD = Standard Deviations of Solvent to Freon Ratios
          RSD = 100 x SD/Mean
          Median = Median of Solvent to Freon Ratios
          RMSD = Normalized Root Mean Square Deviation of Sample x Solvent Means
All Samples (N=20)
Solvent
Sep. Funnel Freon
Hexane
80/20
Freon
Mean
1.00
096
1.13
0.76
SD
-
0 38
049
0.33
RSD
-
39
43
44
Median
1.00
095
I 16
0.78
RMSD
1.7"
3.5
4.6
4.5
Non-Petroleum (N=5)
Solvent
Sep. Funnel Freon
Hexane
80/20
Freon
Mean
1.00
1.07
1.13
0.72
SD
-
0.38
0.24
0.22
RSD
-
36
21
31
Median
1.00
1.08
1.19
0.77
RMSD
2.6'
1.6"
1.8"
6.2
Petroleum (N=15)
Solvent
Sep. Funnel Freon
Hexane
80/20
Freon
Mean
1.00
0.93
1.13
0.78
SD
-
0.39
0.55
0.37
RSD
-
42
49
47
Median
1.00
0.93
1.13
0.80
RMSD
1.8-
3.7
4.8
4.3
30
                                                         June 1993

-------
          Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
                                            Exhibit  10.
   Summary Statistics For Alternative Techniques in the Determination of Oil and Grease
                           Aqueous Waste Stream, Infrared Analysis
           * Acceptance Limit
1 Value Below Acceptance Limit
          Mean = Mean of Solvent to Freon Ratios
          SD = Standard Deviations of Solvent to Freon Ratios
          RSD = 100 x SD/Mean
          Median = Median of Solvent to Freon Ratios
          RMSD = Normalized Root Mean Square Deviation of Sample x Solvent Means
All Samples (N=36)
Solvent
Sep. Funnel Freon
Flon
Mean
1.00
1.62
SD
--
1.55
RSD
--
96
Median
1.00
1.01
RMSD
1.5'
8.3
Non-Petroleum (N=I3)
Solvent
Sep. Funnel Freon
Flon
Mean
1.00
2.33
SD
--
2.29
RSD
-
98
Median
1.00
2.05
RMSD
2.0'
9.4
Petroleum (N=23)
Solvent
Sep. Funnel Freon
Flon
Mean
1.00
1.21
SD
-
0.71
RSD
-
58
Median
1.00
1.00
RMSD
1.7'
6.4
June 1993
                                                                 31

-------
Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
                                            Exhibit 11.
                           Normalized Root Mean Square Deviations
                    Aqueous Waste Stream, Separatory Funnel Extraction
 5.0 -


 4.5 -


 4.0 -



 3.5 -


 3.0 -


 2.5 -


 2.0 -


 1.5 -


 1.0 -


 0.5 -
  0.0
O
                                        o
             O
                           o
                                                      o
                Hexane         MeCl2       Perchlor

                                           Solvent
                                      DuPont
80/20
                                                                     O  Non-Petroleum

                                                                     •  Petroleum
                                                                       Non-Petroleum
                                                                       Acceptance Limit
                                                                          Petroleum
                                                                       Acceptance Limit
      NOTE: Points below the respective Acceptance Limit are not significantly different from separatory funnel extraction with Freon
32
                                                                                         June 1993

-------
          Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
                                             Exhibit  12.
                            Normalized Root Mean Square Deviations
                             Solid Waste Stream, S.oxhlet Extraction
5.0 -,

4.5 -

4.0 -

3.5 -

3.0

2.5

2.0 -

1.5 -

1.0 -

0.5 -
 0.0
                   O
                                 O
                                                             0
                                                           DuPont
                                                                        80/20
                                                                                    C  Non-Petroleum
                                                                                    •  Petroleum
                                                                                           Non-Petroleum
                                                                                          Acceptance Limit
                                                                                             Petroleum
                                                                                          Acceptance Limit
            Hexane         MeCl2        Perchlor
                                       Solvent
Note: Points below the respective Acceptance Limit are not significantly different from separatory funnel extraction with Freon
June 1993
                                                                                                 33

-------
Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
                                            Exhibit  13.
                            Normalized  Root Mean Square Deviations

                           Solid Waste Stream, Sonication Extraction
 5.0 -i



 4.5 -



 4.0 -



 3.5 -



 3.0 -



 2.5 -



 2.0 -



 1.5 -



 1.0 -



 0.5 -
  0.0
O
              o
                                         O
                            o
                                                       o
                 Hexane        MeCl2       Perchlor

                                            Solvent
                                       DuPont
80/20
               O  Non-Petroleum

               •  Petroleum
               O
               •
                                                                        Non-Petroleum
                                                                       Acceptance Limit

                                                                          Petroleum
                                                                       Acceptance Limit
Freon
     NOTE: Points below the respective Acceptance Limit are not significantly different from separatory funnel extraction with Freon
34
                                                                       June 1993

-------
          Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
                                          Exhibit 14.
                           Normalized Root Mean Square Deviations
                       Aqueous Waste Stream, Alternative Techniques
                                    Non-Petroleum  Samples
 15 -i
 12 -
  9-
  6-
  3 -
               v
v  SPE 47 mm Disk
T  SPE 90 mm Disk
c  SPE Column (new)
•  Infrared
  Acceptance Limit
     SPE Column
  ** SPE Disk
     Infrared
             Hexane      MeCl2     Perchlor      80/20       Freon      MTBE       Flon

                                              Solvent

    NOTE: Points below the respective Acceptance Limit are not significantly different from separatory funnel extraction with Freon
June 1993
              35

-------
   Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
                                           Exhibit 15.
                            Normalized Root Mean Square Deviations
                         Aqueous Waste Stream, Alternative Techniques
                                       Petroleum Samples
     10 -i
      6 -
Q
1/3
      4 -
      2 -
                                                                      v
                                                                      T
                                       V
                    v SPE 47 mm Disk
                    T SPE 90 mm Disk
                    a SPE Column (new)
                    • Infrared
                                                            v
                  D
                       Acceptance Limit
                         SPE Column
                     r...  SPE Disk
                         Infrared
                Hexane      MeCl2     Perchlor     80/20

                                          Solvent
Freon
MTBE
Flon
   36
                         June 1993

-------
             Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
                                            Exhibit 16.

                       Mean Solvent-Freon Ratios for All Techniques Tested
o
CO
      MTBE
       Flon
      Freon
     DuPont
       80/20
    Perchlor
     Hexane
           0.2
O
                          O  D
Id
Ra


>

eal
tio


V


Legend
<- Aqueous
• Soxhlet
C Sonication
G SPE Column (old)
A SPE Column (new)
O SPE Disk 47 mm
* SPE Disk 90 mm
• Infrared
                              BD
                         O
                   O
                                                                      A
                                                            1.0
                                         Solvent to Freon Ratio
                                                                            A i
O
                                                             2.0      2.6
    June  1993
                                                                         37

-------

-------
                                                                            SECTION 6
                                                   PHASE I STUDY CONCLUSIONS
       The purpose of Phase I of this study was to find an alternative solvent or
extraction/measurement technique that yields results equivalent to the results produced using Freon
113 and gravimetry. No solvent or technique produced results exactly equivalent to Freon 113, but as
shown in Exhibits 1 through 16, some solvents can be considered to be equivalent to Freon 113 for
some sample matrices. This section summarizes some of the conclusions that can be drawn from
results to date.

6.1    Alternative Solvents for Existing Methods 413.1, 9070 and 9071A

       Methods 413.1, 9070 and 9071A are the three EPA oil and grease methods currently used for
regulatory compliance monitoring in the NPDES and RCRA programs.
       Among the five solvents tested as possible replacements for Freon 113 in Methods 413.1,
9070 and 9071 A, /z-hexane had the greatest number of results equivalent to Freon 113. Hexane had
two acceptable RMSDs out of a possible four (separately funnel extraction of non-petroleum aqueous
samples and Soxhlet extraction of petroleum-based solid samples). Perchloroethylene had  one
acceptable RMSD (separatory funnel extraction of non-petroleum aqueous samples) as did the 80/20
mixture (Soxhlet extraction of petroleum-based solid samples). Methylene chloride and DuPont 123
had no acceptable  RMSDs for the separatory funnel or  Soxhlet extraction. Based on the current
extraction techniques for aqueous and solid samples (separatory funnel extraction and Soxhlet
extraction, respectively), n-hexane is the most promising candidate replacement solvent for Freon
113. Exhibit 17 below summarizes these conclusions.

                                        Exhibit 17.
                   Summary of Solvents Using Conventional Techniques
                          with RMSDs within Acceptance Limits
Sample Stratum
All
Petroleum
Non-Petroleum
Solvents with Significant RMSDs
Separatory Funnel Extraction
(Aqueous Samples)
None
None
n-hexane
perchloroethylene
Soxhlet Extraction
(Solid Samples)
None
n-hexane
80/20
None
June 1993
39

-------
Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
6.2   Sonication as an Alternative Technique to Soxhlet Extraction

       For sonication as an alternative extraction technique, perchloroethylene was equivalent to
Soxhlet extraction with Freon 113 for petroleum samples.  Therefore, perchloroethylene is a leading
candidate replacement solvent if sonication is considered on an equal footing with the currently-used
Soxhlet extraction technique. Perchloroethylene and n-hexane would both have two acceptable
RMSDs out of a possible six.

6.3   Alternative Techniques for Aqueous Samples

       None of the alternative techniques for aqueous samples yielded results with RMSDs within the
Acceptance Limits when an adequate number of samples was tested. Some of the results using the
Varian SPE columns, particularly the newer version, are promising. It remains to be seen, however,
whether solid phase extraction (SPE) is applicable to samples with high dissolved solids. Without
further work, none of the alternative techniques for aqueous samples can be recommended as a
replacement for methods 413.1 and 9070 at this time.

6.4   Retention and Elimination  of  Solvents for Further  Study

       Based on these results and the results of the earlier study by EMSL-Ci, the following solvents
will be retained or eliminated from further consideration as candidates for replacement of Freon 113
in oil and grease measurement as follows:

       1.  n-hexane will be retained because the results for petroleum-based solid samples and non-
           petroleum aqueous samples are  within the Freon 113 Acceptance Limit and because n-
           hexane was used in the oil and grease measurement prior to  the advent of Freon 113.

       2.  Perchloroethylene will be retained because the results for non-petroleum aqueous samples
           are within the Freon 113 Acceptance Limit and because perchloroethylene can be used in
           the measurement of oil and grease by infra-red techniques.

       3.  n-hexane/MTBE (80/20) will be retained because it is the solvent developed by EMSL-Ci
           in the preliminary study and because the results produced are within the  Freon 113
           Acceptance Limit for petroleum-based solid samples.

       4.  Methylene chloride will be eliminated because the results produced are far from results
           produced by Freon 113.

       5.  DuPont 123 will be eliminated because results produced using this solvent are not within
           the Freon 113 Acceptance Limit for any category of solid or aqueous  samples and because
           DuPont 123 is a Class II CFC that will need to be phased out eventually.
 40                                                                                June 1993

-------
         Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
 6.5    Retention of Alternative Techniques for Further Study

        Of the alternative techniques evaluated in this study, only sonication extraction of non-
 petroleum solid samples produced results equivalent to existing techniques with Freon 113. The use of
 smaller solvent volumes required by solid phase extraction (SPE) and the  increased sensitivity of the
 non-dispersive infrared technique might warrant further study.
June  1993                                                                                 41

-------

-------
                                                                                SECTION  7
                              FOLLOW-UP AND  POSSIBLE PHASE II ACTIVITIES
       A presentation of preliminary results was made at the Pittsburgh Conference on Analytical
Chemistry and Applied Spectroscopy in Atlanta, Georgia on March 4, 1993, and a U.S.
Environmental Protection Agency (EPA) workshop was held on May 4,  1993 in Norfolk, Virginia for
all interested parties to discuss the preliminary results of Phase I and possible options for Phase II. A
second workshop is scheduled to be held in Boston, Massachusetts on June 30, 19935.
       A notice of the availability of the results of the first phase of the study will be published in
the Federal Register, with a request for public comment. This report, with subsequent revisions, if
any, will be mailed to those responding to the notice. The notice may also include a study plan for the
second phase of the study and a request for regulated industries to produce data using the one or two
most promising alternative solvents.
       If EPA proceeds with a second study phase, it will likely be designed to assess the precision,
accuracy, and comparability of the one or two most promising alternative solvent/extraction systems
and measurement techniques from the Phase I study results. The range of industrial effluents might
also be expanded in the second phase, in part through cooperative efforts sponsored by  various
regulated  industries. Alternatively, the second phase of the study may involve side-by-side testing of
an alternative solvent versus Freon 113, so that each permittee can develop its own correction factor
(see below) pending renewal of their NPDES or RCRA permit.

Options for Replacement of Freon 113 in the Oil & Grease Method

       The Phase I results have shown that no solvent produces results identical to the  results
produced  by Freon 113, but that n-hexane, perchloroethylene, and the 80/20 mixture of Az-hexane and
MTBE produce results equivalent to Freon 113 for some samples. These results suggest that if an
immediate decision to replace Freon 113 needs to be made, one or more of these solvents should be
selected, and that any Phase II effort should concentrate on these solvents. The reduction in solvent
use afforded by solid phase extraction and the lowered detection limit attained with non-dispersive
infrared determination, however, provide compelling reasons for further study of these techniques.
EPA therefore desires to be as comprehensive as possible in exploring options for any possible Phase
II study, but needs to narrow  the focus of these options once they have been  explored.
       The range of options under consideration at this time is given below.

       •   File for an exemption under the Clean Air Act Amendments for the use of Freon 113 in
           the  oil and grease method.
       •   Use recycled Freon.  Laboratories would reuse Freon 113 recovered from earlier testing.
   'Conference arrangements for the Oil and Grease Workshop are being coordinated by DynCorp Viar, Inc. For additional information, please
contact Christopher Berry at (703)519-1387.


June 1993                                                                                  43

-------
Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease	


       •   Choose one new solvent.
       •   Choose more than one new solvent, if different solvents are found to work best on
           different  kinds of samples.
       •   Use the Total Petroleum Hydrocarbon (TPH) method for petroleum-contaminated
           samples.
       •   Switch from gravimetric to infrared spectroscopy-based methods.
       •   Use solid phase extraction (SPE) rather than solvent extraction.
       •   Develop  a correction factor or factors to be applied to data generated by solvents other
           than Freon 113.

       EPA solicits  comments on these options and seeks any other  options for resolution of this
issue. As comments  and other information become available, the Agency will continue to attempt to
keep all interested parties informed. Because Freon 113 will not be commercially available  after
January 1,  1996, and because it is desirable to  phase out the use of all Class I CFCs as expeditiously
as possible, the first  two options listed above may not be viable.
 44                                                                                  June 1993

-------
  APPENDIX A
SITE SUMMARY

-------

-------
            Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
                                                   Exhibit A-1.
                                                  Site Summary
                                           Freon  Replacement Study
                                                                                   WASTE STREAMS
        FACILITY TYPE
 Paper Mitt
 Oil Production Site
 POTU

 Leather Tannery
 POTU
 Petroleum Refinery

 Industrial Laundry
 Textile Mill
 Metal Finishing Plant
 Fish Oil Plant
 Rendering Plant
 Coke Plant
 Slaughterhouse

 Wood Preserving Plant
 Drilling Fluid Supplier
 Soils
 PwUryvPlant
 Rolling Hill
 Oil Terninat
 Mayonnaise Plant
 Seafood: Plant
 Abrasives Plant
 Seafood Plant
 Meat Packing Plant
 Railroad Yard
 Can Manufacturing Plant
 Soup Plant
 Oily Water Treatment Plant
 Can Manufacturing Plant
 Can Manufacturing Plant

 Drum HarxiUng f aci I i ty
 Polymer Plant
 Restaurant
 Industrial Laundry
 forttuta;t ing Plant
 Leather Tannery
 Petroleum Refinery
                                        INDUSTRIAL
                                    CATEGORY/ACTIVITY
Pulp & Paper
Oil & Gas Extraction
POTW

Leather Tanning
POTW
Petroleum Refining

Industrial Laundries
Textile Manufacturing
Metal Finishing
Soap & Detergent Hanf.
Heat Products  & Rendering
Iron & Steel Manufacturing
Meat Products  & Rendering

Timber Products
Oil & Gas Extraction
Contaminated Soils
Poultry Processing
Iron & Steel Manufacturing
Petroleum Storage Facilities
Miscellaneous  Foods
Seafood Processing
Abrasives Manufacturing
Petroleum Storage Facilities
Seafood Processing

Poultry Processing
Meat Products  & Rendering
Transportation Facilities
Coil Coating
Miscellaneous  Foods
Shore Reception Facilities
Coit: Coating
Coil Coating

Drum Recondi tioning
Organic Chemicals
Food; Retail
Industrial Laundries
Soap: & Detergent Manf.
Leather Tanning
Petroleum Refining
                                                                         AQUEOUS
                                                                                                     SOLID/SLUDGE
Bleach Plant Effluent
Dispersed Gas Flotation Eff.
Primary Effluent
Secondary Effluent
Primary Effluent

API Separator Effluent
Secondary Effluent
Dissolved Air Flotation Eff.
Lagoon Effluent
Separator Effluent
Primary Effluent
Primary Effluent
Secondary Effluent
Primary Effluent
Secondary Effluent
Secondary Effluent
Secondary Effluent
Filter Effluent
Separator Effluent
Filter Effluent
Secondary Effluent
Process Wastewater
Separator Effluent
Primary Effluent

Dissolved Air Flotation Inf.
Lagoon Effluent
Dissolved Air Flotation Eff.
Primary Effluent
Dissolved Air Flotation Eff.
Separator Effluent
Dissolved Air Flotation tnf.
Dissolved Air Flotation Inf.
Dissolved Air Flotation Eff.
Filter Effluent
Secondary Effluent

Primary Effluent
PrSmagy Effluent
Primary Effluent
API Separator Effluent
Interceptor Effluent
Dewatered Sludge

Dewatered Sludge

Dewatered Sludge
Digested Sludge
API Separator Sludge

DAF Sludge


Oily Sludge

Waste Activated Sludge
Solid Waste
Used Drilling Mud
SoiI w/ Kerosene
Waste Activated Sludge
Dewatered Scale Material

Oily Sludge
Waste Sludge
Oily Sludge
Deuatered Sludge
DAF Sludge

Oily Sludge
Filter Cake
DAF Sludge
Oily Sludge
Filter Cake
Filter Cake

Oily; Sludge
Dewatered Sludge
Vegetable Oil Waste
Waste Sludge
June 1993
                                                                                 A-3

-------
Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease


                                                  Exhibit  A-2.
                                            Wastewater Sources
                                          Freon Replacement Study
                                                                                      LEVEL OF TREATMENT
                                                                                   UPSTREAM OF SAMPLE POINT
                   FACILITY TYPE
                                                    AQUEOUS
                                                 WASTE STREAMS
             Slaughterhouse
             Poultry Plant
             Paper Mitt
             Oil  Production Site
             WTVT

             Leather Tannery
             Pet*-t>t«u« «efir»ery

             Industrial Laundry
             Textile »U1
             Metal Finishing Plant
             i&6 :Oit Plant  :
             Rendering Plant
                            plant
             Oil  Terminal
             ilteyonnaise Plant .
             Seafood Plant
             Afarasives Plant
             Oil  Terminal
             feaf^ Plant
             Poultry Plant
             Meat Packing Plant
             Railroad Yard
             Can Manufacturing Plant
             Soup Plant
             Oily Water Treatment Plant
             Can Manufacturing Plant
             Can Hamfectwing plant

             Drum Handling Facility
             piptymer Plant
             Industrial Laundry
             Formulating Plant    :
             Leather Tannery
             Petroleum Refinery
Bleach Plant Effluent
Dispersed Gas  Flotation Eff .
.PrtBary iff ttient
        '
Primary Effluent
API s>paratiaf Eff Soeot ;
Secondary .ffflwent     :
Dissolved Air Flotation Eff.
lagooiv Effluent
Separator Effluent
Primary Iff hient
Primary Effluent
Secondary Effluent
Primary Effluent
Secondary Effluent
Secondary. Effluent
Secondary Effluent
Filter Effluent
Separator Effluent
Filter Effluent
Secondary Effluent
Process Wastewater
Separator Effluent
Primary Effluent
Dissolved Air Flotation Inf.
Lagoon Effluent
Dissolved Air Flotation Eff.
Primary Effluent
Dissolved Air Flotation Eff.
Separator Effluent
Dissolved Air Flotation Inf.
Dissolved Air Flotation Inf.
Dissolved Air Flotation Eff,
Filter Effluent
Secondary £f fluent
Primary Effluent
Primary Effluent
Primary Effluent
API Separator Effluent
interceptor Effluent
                                                                         BASIS
 P
 P
:P
.IP
 N
IP
                                                                                   NONE   PRIM.   SO/U   BIOL.
                               x
                               X
                               X
                                     LEGEND

             BASIS:
                P  -   Petroleum
                N  -   Non-Petroleum

             LEVEL OF TREATMENT:
                NONE   -  No Treatment
                PRIM   -  Primary Treatment
                SO/U   -  Secondary Oil/Water Separation
                BIOL   -  Biological Treatment
 A-4
                                                                                                         June 1993

-------
   APPENDIX B
DATA SUMMARY

-------

-------
                                                                              OIL & GREASE DATA
                                                                           FREON REPLACEMENT STUDY
                                                                                   PHASE I
                                                                                                                      June 21, 1993
                                                                                                                        Page 1 of 25
              FACILITY
   1   PAPER MILL
_SCC|

22221
  WASTE STREAM
BLEACH PLANT EFF
  TECHNIQUE


LIQ/LIQ (A)
                                 22221

                                 22222
          BLEACH PLANT EFF

          DEWATERED SLUDGE
                     INFRARED (A)

                     SONICATION (S)
                                 22222
          DEWATERED SLUDGE
                     SOXHLET (S)
                                 23479
          BLEACH PLANT EFF
                     LIQ/LIQ (A)
                                 23479

                                 23479
                                 23479
          BLEACH PLANT EFF

          BLEACH PLANT EFF
          BLEACH PLANT EFF
                     INFRARED (A)

                     SPE  DISK 90mm (A)
                     SPE  DISK 47mm (A)
      SOLVENT
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

FLON

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

FLON

METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC

METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC
                                                                                                                          Oil  & Grease Concentrations:
                                                                                                                             mg/L in aqueous samples (A)
                                                                                                                             mg/kg in solid/sludge samples (S)
REP1
5.0 <
5.0 <
5.0 <
5.0 <
5.1
5.0 <
2.5
3700.0

1200.0
7800.0
4800.0
1100.0
11000.0
11000.0
6600.0
25000.0
16000.0
11000 0
7.4
5.0 <
5.0 <
8 1
7 0
5 0 <
5.1
14.0
15.0
12.0
61 0
11 0
22.0
32 0
29.0
76.0
28.0
REP2






2.4
2700.0
3400.0
1100.0
320.0
1500.0
2400.0
12000.0
5300.0
2400.0
26000.0
5000.0
6500 0
7.7
5.0 <
5 0 <
8 9
6.5
5.0 <
4.3
13.0
16.0
13.0
66 0
11 0
20.0
24.0
32.0
85.0
26.0
REPS







2300.0
2000.0
1300.0
8800.0
2900.0
1900.0
10000 0
7900.0
11000.0
27000.0
7700.0
6900.0
6.3
5.0 <
5.0 <
8.1
5.8
5.8











MEAN
5.0 <
5.0 <
5.0 <
5.0 <
5.1
5.0 <
2.5
2900.0
2700.0
1200.0
5700.0
3100.0
1800 0
11000.0
8000.0
6600.0
26000.0
9500.0
8000 0
7 1
5.0 <
5.0 <
8.3
6.4
5.3
4.7
14 0
15.0
13.0
63.0
11.0
21.0
28.0
30.0
80.0
27.0
STD. DEV.






0.1
679.3
1036.3
101.3
4652.9
1616.9
673 1
909.5
2762.2
4203.1
925.9
5560.2
2214.9
0.8


0.4
0 6
0 4
0.6
0.8
0.2
1.3
3.8
0.3
1.1
5.4
2.5
6.2
1.3
SPE Disk Values are not blank-corrected since blanks were not  analyzed  for  two  solvents,  and the remaining solvents  had blank values < 1 mg/L.

-------
                                                                              OIL  & GREASE DATA
                                                                           FREON REPLACEMENT STUDY
                                                                                   PHASE I
                                                                                                                      June 21, 1993
                                                                                                                        Page 2 of 25
              FACILITY
   2   OIL PRODUCTION SITE
 SCCI

23479



22223
  WASTE STREAM
                                           BLEACH PLANT EFF
DGF EFFLUENT
  TECHNIQUE

SPE COLUMN II  (A)
LIQ/LIQ (A)
                                 22223

                                 22223
          DGF EFFLUENT

          DGF EFFLUENT
                     INFRARED (A)

                     SPE  COLUMN  I  (A)
   3   POTW
22224
PRIMARY EFFLUENT
LIQ/LIQ (A)
                                 22224

                                 22238
          PRIMARY EFFLUENT

          SEWAGE SLUDGE
                     INFRARED (A)

                     SONICATION  (S)
                                 22238
          SEWAGE SLUDGE
                     SOXHLET  (S)
      SOLVENT
FREON
HEXANE
80/20

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

FLON

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

FLON

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
                                                                                                                         Oil  & Grease  Concentrations:
                                                                                                                            mg/L  in  aqueous  samples  (A)
                                                                                                                            mq/kq in solid/sludge  samples  (S)
REP1
6.0
5.0 <
12.0
23.0
5.0 <
27.0
15.0
5.0 <
44.0
15.0
11.0
8.4
14.0
10.0
10.0
16.0
30.0
18.0
43.0
24.0
31.0
5.0 <
13.0
37000.0
46000.0
20000.0
46000.0
22000.0
23000.0
120000.0
98000.0
110000.0
120000.0
140000.0
100000.0
REP2
5.0 <
5.0 <
5.0 <
17.0
42.0
29.0
23.0
5.0 <
31.0
15.0
11.0
9.3
18.0
13.0
16.0
16.0






14.0
35000.0
40000.0
27000.0
45000.0
23000.0
19000.0
110000.0
81000.0
86000.0
140000.0
160000.0
81000.0
REPS



20.0
5.0 <
27.0
42.0
32.0
19 0

12.0
9.4
13.0
22.0
12.0
12.0







37000.0
37000.0
21000.0
40000.0
26000.0
26000.0
110000.0
81000.0
80000.0
150000.0
110000.0
72000.0
MEAN
5.5
5.0 <
8.5
20.0
17.0
27.0
27.0
14.0
31.0
15.0
11.0
9.0
15.0
15.0
13.0
15.0
30.0
18.0
43.0
24.0
31.0
5.0 <
13.0
36000.0
41000.0
22000.0
44000.0
24000.0
22000.0
110000.0
87000.0
91000.0
140000.0
130000.0
84000.0
STD. DEV.
0.7

4.9
2.9
21.3
1.0
14.0
15.4
12.3
0.2
0.5
0 5
2.7
5.9
2 6
2.1






0.2
867.0
4211.9
3894.8
2996.8
2203.7
3487.1
4041.5
9940.5
13281.3
14364.3
26764.4
14360.0
SPE Disk Values are not blank-corrected since blanks  were  not  analyzed for two solvents, and the remaining solvents had blank values < 1 mg/L.
                                                                                     B-2

-------
                                                                              OIL & GREASE DATA
                                                                           FREON REPLACEMENT STUDY
                                                                                   PHASE I
                                                                                                                      June 21. 1993
                                                                                                                        Page 3 of 25
              FACILITY
 SCC#

23116
  UASTE STREAM
TECHNIQUE
                                           SECONDARY EFFLUENT   LIQ/LIQ  (A)
       LEATHER TANNERY
23116

22225
SECONDARY EFFLUENT   INFRARED (A)

PRIMARY EFFLUENT     LIQ/LIQ (A)
                                 22225

                                 22226
          PRIMARY EFFLUENT     INFRARED  (A)

          DEWATERED SLUDGE     SONICATION  (S)
                                 22226
          DEWATERED SLUDGE      SOXHLET  (S)
   5   POTW
22227
DIGESTED SLUDGE       SONICATION  (S)
                                 22227
          DIGESTED  SLUDGE      SOXHLET  (S)
                                                                                         SOLVENT
                 DUPONT123
                 FREON
                 HEXANE
                 METHYLENE CHLORIDE
                 PERCHLOR
                 80/20

                 FLON

                 DUPONT123
                 FREON
                 HEXANE
                 METHYLENE CHLORIDE
                 PERCHLOR
                 80/20

                 FLON

                 DUPONT123
                 FREON
                 HEXANE
                 METHYLENE CHLORIDE
                 PERCHLOR
                 80/20

                 DUPONT123
                 FREON
                 HEXANE
                 METHYLENE CHLORIDE
                 PERCHLOR
                 80/20

                 DUPONT123
                 FREON
                 HEXANE
                 METHYLENE CHLORIDE
                 PERCHLOR
                 80/20

                 DUPONT123
                 FREON
                 HEXANE
                 METHYLENE CHLORIDE
                 PERCHLOR
                 80/20
                                                                                                                          Oil  & Grease Concentrations:
                                                                                                                             mg/L in aqueous samples (A)
                                                                                                                             mg/kq in solid/sludge samples  (S)
REP1
5.0 <
5.0 <
5.4
5.0 <
23.0
5.0 <
0.0
540.0
89.0
30.0
74.0
110.0
920.0
200.0
10000.0
10000.0
11000.0
8800.0
12000.0
6300.0
31000.0
11000.0
21000.0
62000.0
29000.0
23000.0
61000.0
70000.0
2200.0
53000.0
100000.0
4100.0
67000.0
130000.0
54000.0
120000.0
160000.0
88000.0
REP2
5.0 <
5.0 <
5.0 <
5.0 <
9.3
5.0 <
0.0
1200.0
80.0
49.0
51.0
65.0
580.0
230.0
15000.0
7900.0
5300.0
6900.0
14000.0
10000.0
27000.0
12000.0
15000.0
54000.0
18000.0
26000.0
50000.0
36000.0
30000.0
66000.0
63000.0
3900.0
190000.0
97000.0
76000.0
54000.0
82000.0
73000.0
REPS
5.0 <
5.0 <
5.0 <
5.0 <
11.0
5.0 <

3200.0
53.0
23.0
39.0
80.0
1500.0

15000.0
11000.0
9800.0
6300.0
20000.0
10000.0
23000.0
12000.0
19000.0
58000.0
23000.0
20000.0
22000.0
82000.0
50000.0
56000.0
110000.0
12000.0
220000.0
66000.0
48000.0
97000.0
190000.0
67000.0
MEAN
5.0 <
5.0 <
5.1
5.0 <
15.0
5.0 <
0.0
1700.0
74.0
34.0
55.0
84.0
1000.0
220.0
13000.0
9600.0
8700.0
7400.0
15000.0
8900.0
27000.0
12000.0
18000.0
58000.0
23000.0
23000.0
44000.0
63000.0
28000.0
58000.0
91000.0
6800.0
160000.0
98000.0
59000.0
91000.0
140000.0
76000.0
STD. DEV.


0.3

7.6


1381.6
18.4
13.7
18.1
21.6
465.8
21.2
2857.7
1502.5
2921.8
1320.5
4348.8
2271.5
3998.2
731.9
3201.0
4070.3
5814.3
2839.9
20031.4
23699.5
24101.2
7064.5
24297.9
4758.3
80184.4
33027.6
14515.9
34967.3
55096.7
10530.1
SPE Disk Values are not blank-corrected since  blanks were not analyzed for two solvents, and the  remaining solvents had  blank values <  1 mg/L.

-------
                                                                              OIL & GREASE DATA
                                                                           FREON REPLACEMENT STUDY
                                                                                   PHASE I
                                                                                                                       June 21,  1993
                                                                                                                         Page 4  of 25
              FACILITY
   6   PETROLEUM REFINERY
 SCC#


22228
  WASTE STREAM
  TECHNIQUE
API SEPARATOR EFF    LIQ/LIQ (A)
                                 22229
          SECONDARY EFFLUENT   LIQ/LIQ (A)
                                 22229

                                 22229
                                 22230
          SECONDARY EFFLUENT   INFRARED (A)

          SECONDARY EFFLUENT   SPE COLUMN I  (A)
          API SEPARATOR SLUDGE SONICATION (S)
                                 22230
          API SEPARATOR SLUDGE SOXHLET (S)
   7   INDUSTRIAL LAUNDRY
22231
DAF EFFLUENT
LIQ/LIQ (A)
      SOLVENT
                                 22231
          DAF EFFLUENT
                     INFRARED (A)
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

FLON

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
80/20

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

FLON
                                                                                                                          Oil & Grease Concentrations:
                                                                                                                             mg/L in aqueous samples  (A)
                                                                                                                             rnq/kq in solid/sludge samples  (S)
REP1
35.0
24.0
32.0
20.0
12.0
28.0
9.5
5.0 <
5.0 <
5.0 <
11.0
5.0 <
6.4
5.0 <
5 0 <
5.0 <
5.6
5.4
210000.0
140000.0
200000.0
160000.0
180000.0
190000.0
240000.0
320000.0
240000 0
290000.0
200000.0
280000.0
130.0
62 0
76.0
120.0
88.0
67.0
REP2
31.0
14.0
35.0
11.0
29.0
37.0
11.0
5.0 <
5.0 <
5.0 <
5 0 <
14 0
6.4
5.0 <
5.0 <
5 0 <
5 6
5.2
200000.0
190000.0
220000.0
160000.0
160000.0
200000.0
310000.0
350000.0
320000.0
280000 0
280000 0
250000.0
100.0
74.0
30.0
83.0
91.0
46.0
REPS
25.0
17.0
29.0
5.0 <
28.0
23.0
7.5
5.0 <
5.0 <
5.0 <
5.0 <
8.0

5.0 <
5.0 <
5.0 <
5.4
5.8
220000.0
230000.0
200000.0
140000.0
180000.0
220000.0
280000.0
250000.0
240000.0
280000.0
240000.0
360000.0
80.0
94.0
66.0
97.0
92.0
39 0
MEAN
30.0
18.0
32.0
12.0
23.0
29.0
9.3
5.0 <
5.0 <
5.0 <
7.0
8 9
6.4
5.0 <
5 0 <
5 0 <
5.5
5.5
210000.0
190000.0
210000.0
150000.0
170000.0
200000 0
280000.0
310000.0
270000.0
280000.0
240000.0
300000.0
100.0
77.0
57.0
99.0
90.0
51.0
STD. DEV.
5.1
5.3
2.9
7.6
9.5
7.2
1.7



3.5
4.4




0.1
0.3
10148.9
46177.2
9609.0
14153.9
8888.2
15534.9
32187.0
53257.2
43821.6
5033.2
41036.6
54555.8
24.5
16.1
24.2
17.4
2.3
14.2
                                             150.0
160.0
150.0
                                                                                                                                                                       4.9
SPE Disk Values are not blank-corrected since blanks were not analyzed  for  two  solvents,  and  the  remaining solvents  had blank values < 1 mg/L.
                                                                                     B-4

-------
                                                                              OIL & GREASE  DATA
                                                                           FREON REPLACEMENT STUDY
                                                                                   PHASE  I
                                                                                                                      June  21,  1993
                                                                                                                         Page  5  of 25
              FACILITY
 SCCf
23463
  WASTE STREAM
                                           DAF EFFLUENT
  TECHNIQUE
LIQ/LIQ (A)
                                 23463
                                 23463
                                 23463
                                 23464
          DAF EFFLUENT
          DAF EFFLUENT
          DAF EFFLUENT
          DAF SLUDGE
                     INFRARED (A)
                     SPE DISK 90mm (A)
                     SPE DISK 47mm (A)
                     SONICATION (S)
                                 23464
          DAF SLUDGE
                     SOXHLET (S)
   8   TEXTILE MILL
22232
LAGOON EFFLUENT
LIQ/LIQ (A)
                                                                                                                          Oil & Grease  Concentrations:
                                                                                                                             mg/L  in aqueous samples  (A)
                                                                                                                             mg/kg  in solid/sludge  samples  (S)
SOLVENT
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
FLON
METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC
METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
REP1
620.0
630.0
400.0
440.0
450.0
510.0
590.0
450.0
260.0
290.0
250.0
390.0
640.0
320.0
280.0
750.0
420.0
110000.0
170000.0
230000.0
130000.0
100000.0
170000.0
260000.0
310000.0
290000.0
360000.0
180000.0
280000.0
58.0
34.0
6.4
140.0
64.0
25.0
REP2
670.0
650.0
440.0
340.0
550.0
380.0
570.0
430.0
250.0
290.0
400.0
490.0
610.0
430.0
250.0
410.0
460.0
140000.0
190000.0
200000.0
140000.0
120000.0
120000.0
280000.0
310000.0
360000.0
140000.0
150000.0
280000.0
18.0
46.0
55.0
160.0
58.0
14.0
REPS
550.0
590.0
370.0
500.0
460.0
430.0











150000.0
240000.0
270000.0
94000.0
110000.0
120000.0
280000.0
240000.0
180000.0
220000.0
130000.0
280000.0
21.0
74.0
22.0
49.0
31.0
11.0
MEAN
610.0
620.0
400.0
430.0
490.0
440.0
580.0
440.0
260.0
290.0
330.0
440.0
630.0
380.0
270.0
580.0
440.0
130000.0
200000.0
240000.0
120000.0
110000.0
140000.0
270000.0
290000.0
280000.0
240000.0
150000.0
280000.0
32.0
51.0
28.0
120.0
51.0
17.0
STD. DEV.
58.7
31.1
35.3
82 8
58.1
66.6
18.4
12 7
12 7

106.8
68.6
17 7
81.3
21 2
234.8
25.5
17175.8
35483.4
35964.3
24904.3
9558.2
29936.9
10924.7
41716.8
90818.8
110232.9
25636.6
1035.9
22.7
20 3
24.9
61.9
17.8
7.5
                                 22232
          LAGOON EFFLUENT
                     INFRARED  (A)
                   FLON
110.0
                                                                                                                           110.0
                                                                                                                      110.0
                                                                                                                            0.7
SPE Disk: Values are not blank-corrected since blanks were not analyzed  for two solvents,  and the remaining solvents had blank values < 1 mg/L.
                                                                                     B-5

-------
                                                                              OIL & GREASE DATA
                                                                           FREON REPLACEMENT STUDY
                                                                                   PHASE I
                                                                                                                       June 21, 1993
                                                                                                                         Page 6 of 25
              FACILITY
 SCCI
  WASTE STREAM
  TECHNIQUE
   9   METAL FINISHING PLANT     22233     SEPARATOR EFFLUENT   LIQ/LIQ (A)
  10   FISH OIL PLANT
22233
22233

22234
SEPARATOR EFFLUENT
SEPARATOR EFFLUENT

PRIMARY EFFLUENT
INFRARED (A)
SPE DISK 90mm (A)

LIQ/LIQ (A)
                                 22234
                                 22234

                                 22235
          PRIMARY EFFLUENT
          PRIMARY EFFLUENT

          OILY SLUDGE
                     INFRARED (A)
                     SPE DISK 90mm (A)

                     SONICATION  (S)
                                 22235
          OILY SLUDGE
                     SOXHLET (S)
  11   RENDERING PLANT
22236
PRIMARY EFFLUENT
LIQ/LIQ (A)
                                                                                                                          Oil & Grease Concentrations:
                                                                                                                             mg/L in aqueous samples  (A)
                                                                                                                             nig/kg in solid/sludge samples  (S)
SOLVENT
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
FLON
METHYLENE CHLORIDE
HEXANE
MTBE
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
FLON
METHYLENE CHLORIDE
HEXANE
MTBE
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
REP1
35.0
5.0 <
25.0
15.0
15.0
21.0
8.9
18.0
7.1
18.0
660.0
570.0
500.0
750.0
670.0
580.0
290.0
510.0
460.0
540.0
280000.0
280000.0
390000.0
330000.0
880000.0
230000.0
800000.0
890000.0
440000.0
780000.0
580000.0
620000.0
5.0 <
56.0
5.0 <
320.0
5.1
5.0 <
REP2
66.0
5.0 <
22.0
5.0 <
22.0
20.0
9.9
28.0
8.3
25.0
680.0
530.0
490.0
720.0
470.0
540.0
290.0
540.0
430.0
490.0
190000.0
240000.0
210000.0
250000.0
790000.0
230000.0
780000.0
1000000.0
530000.0
790000.0
350000.0
590000.0
5.0 <
30.0
5.0 <
240.0
9.7
5.2
REPS
34.0
5.0 <
17.0
13.0
12.0
21.0




690.0
500.0
500.0
650.0
710.0
620.0




230000.0
210000.0
420000.0
340000.0
830000.0
390000.0
770000.0
770000.0
460000.0
760000.0
360000.0
560000.0
5.0 <
27.0
5.0 <
780.0
62.0
25.0
MEAN
45.0
5.0 <
22.0
11.0
16.0
21.0
9.4
23.0
7.7
22.0
680.0
530.0
500.0
700.0
620.0
580.0
290.0
520.0
450.0
520.0
230000.0
240000.0
340000.0
310000.0
830000.0
280000.0
790000.0
890000.0
480000.0
780000.0
430000.0
590000.0
5.0 <
38.0
5.0 <
450.0
25.0
12.0
STD. DEV.
18.0

4.0
5.1
5.3
0.5
0.7
7.2
0.8
4.8
13.2
35.7
4.7
53.1
130.8
39.3
2.1
18.4
21.9
33.9
45014.8
37634.2
114823.1
51156.6
44575.8
93275.6
16441.8
131249.1
46317.7
16258.3
126950.1
26514.1

16.2

292.4
31.4
11.5
SPE Disk Values are not blank-corrected since blanks were not analyzed for two solvents,  and the remaining solvents had blank values < 1 mg/L.
                                                                                     B-6

-------
                                                                              OIL & GREASE DATA
                                                                           FREON REPLACEMENT STUDY
                                                                                   PHASE I
                                                                                                                      June 21. 1993
                                                                                                                        Page 7 of 25
              FACILITY
  12   COKE PLANT
_SCCJ


22236

22236



22239
  WASTE STREAM

PRIMARY EFFLUENT

PRIMARY EFFLUENT
  TECHNIQUE


INFRARED (A)

SPE DISK 90mm (A)
SECONDARY EFFLUENT   LIQ/LIQ (A)
                                 22239

                                 22240
          SECONDARY EFFLUENT

          WASTE ACTIV SLUDGE
                     INFRARED (A)

                     SONICATION (S)
                                 22240
          WASTE ACTIV SLUDGE   SOXHLET (S)
  13   SLAUGHTERHOUSE
22241
PRIMARY EFFLUENT
LIQ/LIQ (A)
                                 22241

                                 22242
          PRIMARY EFFLUENT

          SECONDARY EFFLUENT
                     INFRARED (A)

                     SPE  COLUMN  I  (A)
      SOLVENT
FLON

METHYLENE CHLORIDE
HEXANE
MTBE

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

FLON

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

FLON

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
                                                                                                                          Oil  & Grease Concentrations:
                                                                                                                             mg/L in aqueous samples (A)
                                                                                                                             mg/kq in solid/sludge samples (S)
REP1
37.0
68.0
7.1
59.0
5.0 <
5.0 <
5.0 <
5.0 <
25.0
5.0 <
4.6
32000.0
40000.0
24000.0
770000.0
30000.0
14000.0
27000.0
8300.0
14000.0
25000.0
69000.0
9800.0
6.8
5.0 <
6.4
5.0 <
7.3
6.2
46.0
5.0 <
5.0 <
5.0 <
5.0 <
9.9
5.0 <
REP2
30.0
45.0
8.3
56.0
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
4.5
26000.0
30000.0
14000.0
1300000.0
88000.0
75000.0
31000.0
8000.0
19000.0
29000.0
120000 0
15000.0
5.0 <
5.0 <
5.5
5.0 <
15.0
5.0 <
45.0
5.0 <
5.0 <
5.0 <
5.0 <
10.0
5.0 <
REPS




5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <

38000.0
33000.0
13000.0
50000.0
19000.0
48000.0
23000.0
18000.0
15000.0
27000.0
45000.0
11000.0
5.0 <
9.5
15.0
5.0 <
5.0 <
10.0

5.0 <
5.2
5.0 <
5.0 <
10.0
5.0 <
MEAN
34.0
56.0
7.7
58.0
5.0 <
5.0 <
5.0 <
5.0 <
12.0
5.0 <
4.6
32000.0
34000.0
17000.0
720000.0
46000 0
46000 0
27000.0
11000.0
16000.0
27000.0
78000.0
12000.0
5.6
6.5
9.0
5.0 <
9.2
7.1
46.0
5.0 <
5.1
5.0 <
5.0 <
10.0
5.0 <
STD. DEV.
4.9
16.8
0.8
2.5




11.5

0.1
6106.9
5598.0
6280.2
650639.3
37224.4
30839.8
3899.9
5505.4
2732.0
2141.0
39027.1
2738.9
1.1
2.6
5.3

5.4
2.7
0.7

0.1


0.3

SPE Disk Values are not blank-corrected since blanks were not  analyzed  for two  solvents,  and the remaining solvents had blank values < 1 mg/L.
                                                                                     3-7

-------
                                                                              OIL & GREASE DATA
                                                                           FREON REPLACEMENT STUDY
                                                                                   PHASE I
                                                                                                                     June  21.
                                                                                                                        Page £
                                                                                                                    1993
                                                                                                                    of 25
              FACILITY
SCCf
WASTE STREAM
TECHNIQUE
  14   WOOD PRESERVING PLANT     22243     SECONDARY EFFLUENT   LIQ/LIQ  (A)
                                 22243

                                 22244
         SECONDARY EFFLUENT   INFRARED (A)

         SOLID WASTE          SONICATION (S)
                                 22244
         SOLID WASTE
                   SOXHLET (S)
  15   DRILLING FLUID SUPPLIER   22237
         USED DRILLING MUD    SONICATION (S)
                                 22237
         USED DRILLING MUD    SOXHLET (S)
  16   CONTAMINATED SOILS        24020
         KEROSENE CONTAM SOIL SONICATION (S)
                                                                                                                          Oil  & Grease Concentrations:
                                                                                                                             mg/L in aqueous samples (A)
                                                                                                                             mg/kg in solid/sludge samples (S)
SOLVENT
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
FLON
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
REP1
5.0 <
7.0
5.0 <
8.8
17.0
9.9
7.1
87000.0
81000.0
45000.0
120000.0
120000.0
50000.0
180000.0
150000.0
140000.0
140000.0
60000 0
120000 0
2900.0
1600.0
1600.0
4600.0
1200.0
2800.0
410.0
1300.0
1300.0
800.0
1100.0
2000.0
2300.0
1000.0
1900.0
3900.0
2000.0
2400.0
REP2
5.0 <
7.4
5.0 <
5.0 <
5.0 <
11.0
6.1
95000.0
85000.0
52000.0
110000.0
99000.0
54000.0
140000.0
140000.0
130000.0
160000.0
41000.0
140000.0
2900.0
2200.0
1700.0
4400.0
910.0
2900.0
540.0
1600.0
1200.0
950.0
1200.0
1900.0
2100.0
1600.0
2200.0
2500.0
1200.0
1400 0
REPS
5.0 <
5.0 <
5.0 <
5.0 <
74.0
5.0 <

84000.0
83000.0
59000.0
110000.0
180000.0
61000.0
140000.0
140000.0
130000.0
160000.0
170000.0
130000.0
2900.0
1800.0
1500.0
4200.0
1100.0
3500.0
400.0
1300.0
1600.0
1100.0
1500 0
2000.0
1900.0
1400.0
1700.0
3100.0
1600.0
1500.0
MEAN
5.0 <
6.5
5.0 <
6.3
32.0
8.7
6.6
89000.0
83000 0
52000.0
110000.0
130000.0
55000.0
150000.0
140000.0
130000.0
150000.0
89000 0
130000.0
2900.0
1800.0
1600.0
4400.0
1100.0
3100.0
450.0
1400.0
1400.0
930.0
1300.0
2000.0
2100.0
1300.0
1900.0
3100.0
1600.0
1700.0
STD. DEV.

1.3

2.2
37.0
3.3
0.7
5657.3
1895.3
6909.6
3511.9
42922.4
5176.8
19078.8
3511.9
6557.4
15373.1
68169.0
8888.2
18.5
315.3
112.6
191.2
143.5
374.2
80.3
157.0
200.6
124.9
216.6
72.8
229.8
309.3
226.8
689.6
402.7
533.1
SPt Disk Values are not blank-corrected since blanks were not analyzed  for two  solvents,  and the  remaining  solvents had blank  values <  1 mg/L.

-------
                                                                              OIL & GREASE DATA
                                                                           FREON REPLACEMENT STUDY
                                                                                   PHASE  I
                                                                                                                      June 21, 1993
                                                                                                                        Page 9 of 25
              FACILITY
_SCCJ

24020
  WASTE STREAM
                                                                  TECHNIQUE
                                           KEROSENE CONTAM SOIL SOXHLET (S)
  17   POULTRY PLANT
23106     SECONDARY EFFLUENT   LIQ/LIQ (A)
                                 23106     SECONDARY EFFLUENT   INFRARED (A)

                                 23106     SECONDARY EFFLUENT   SPE COLUMN I  (A)
                                 23107     WASTE ACTIV SLUDGE   SONICATION (S)
                                 23107
          WASTE ACTIV SLUDGE    SOXHLET  (S)
  18   ROLLING MILL
23108
FILTER EFFLUENT      LIQ/LIQ  (A)
                                              SOLVENT
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

FLON

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
                                                                                                                          Oil & Grease Concentrations:
                                                                                                                             mg/L in aque9us samples  (A)
                                                                                                                             mg/kg in solid/sludge samples (S)
REP1
1900.0
2000.0
2500.0
1200.0
1900.0
2000.0
5.0 <
8.3
5.0 <
5.0 <
5.0 <
5.0 <
0.0
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
17.0
4100.0
10000.0
2300.0
6800.0
130000.0
2000.0
21000.0
38000.0
5900.0
39000.0
47000.0
10000.0
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
REP2
2100.0
1400.0
3200.0
1300.0
1600.0
1400.0
5.0 <
12.0
5.0 <
5.0 <
37.0
5.0 <
0.0
5.0 <
5.0 <
5.0 <
12.0
5.0 <
5.0 <
7100.0
19000.0
1800.0
1200.0
12000.0
2100.0
22000.0
11000.0
11000.0
52000.0
53000.0
7300.0
5.0 <
26.0
5.0 <
5.0 <
17.0
5.0 <
REPS
2200.0
1900.0
2600.0
1600.0
2100.0
2000.0
5.0 <
8.1
5.0 <
5.0 <
19.0
5.0 <

5.0 <
5.0 <
5.0 <
7.0
5.0 <
5.0 <
7500.0
16000.0
130.0
8000.0
10000.0

13000.0
40000.0
46000.0
9800.0
19000.0
23000.0
5.0 <
5.0 <
5.0 <
5.0 <
13.0
5.0 <
MEAN
2100.0
1700.0
2800.0
1300.0
1900.0
1800.0
5.0 <
9.5
5.0 <
5.0 <
20.0
5.0 <
0.0
5.0 <
5.0 <
5.0 <
8.2
5.0 <
9.0
6200.0
15000.0
1400.0
5300.0
51000.0
2100.0
19000.0
30000.0
21000.0
34000.0
40000.0
13000.0
5.0 <
12.0
5.0 <
5.0 <
12.0
5.0 <
STD. DEV.
148.8
352.3
409.8
221.0
232.7
339.8

2.3


16.2





3.9

6.9
1841.6
4438.1
1112.1
3656.0
69556.7
85.6
5098.0
16262.8
21795.3
21708.6
18069.0
8455.2

12.2


6.2

SPE Disk Values are not blank-corrected since blanks  were  not  analyzed  for two solvents,  and  the  remaining  solvents  had  blank  values  <  1  mg/L.
                                                                                     B-9

-------
                                                                             OIL & GREASE DATA
                                                                          FREON REPLACEMENT STUDY
                                                                                  PHASE I
                                                                                                                      June 21, 1993
                                                                                                                        Page 10 of 25
             FACILITY
 SCCI

23108





23108





23109
  WASTE STREAM
                                                                 TECHNIQUE
                                          FILTER EFFLUENT      SPE DISK 90mm (A)
                                          FILTER EFFLUENT      SPE DISK 47mm (A)
                                          DEWATERED SCALE MAT  SONICATION (S)
                                 23109
          DEWATERED SCALE MAT  SOXHLET (S)
  19   OIL TERMINAL
23110
SEPARATOR EFFLUENT   LIQ/LIQ (A)
                                 23110

                                 23110
                                 23110
          SEPARATOR EFFLUENT   INFRARED (A)

          SEPARATOR EFFLUENT   SPE DISK 90mm (A)
          SEPARATOR EFFLUENT   SPE DISK 47mm (A)
      SOLVENT
METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC

METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

FLON

METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC

METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC
                                                                                                                         Oil & Grease Concentrations:
                                                                                                                            mg/L in aqueous samples (A)
                                                                                                                            mg/kg in solid/sludge samples (S)
REP1
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
8.6
12000.0
21000.0
16000.0
17000.0
18000.0
15000.0
14000.0
11000.0
14000.0
17000.0
18000.0
18000.0
5.0 <
5.0 <
5.1
15.0
20.0
5.0 <
1.0
8.0
5.0 <
5.0 <
15.0
7.8
7.3
5.0 <
5.0 <
11.0
5.0 <
REP2
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
7.0
12000.0
16000.0
17000.0
15000.0
18000.0
16000.0
18000.0
14000.0
14000.0
15000.0
17000.0
19000.0
5.0 <
5.0 <
5.1
8.1
21.0
5.0 <
1.0
6.6
5.0 <
5.0 <
14.0
5.0 <
11.0
5.0 <
5.0 <
12.0
13.0
REPS










13000.0
18000.0
17000.0
14000.0
24000.0
15000.0
18000.0
17000.0
16000.0
18000.0
22000.0
16000.0
5.0 <
11.0
5.8
14.0
5.0 <
18.0











MEAN
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
7.8
13000.0
19000.0
17000.0
15000.0
20000.0
16000.0
16000.0
14000.0
15000.0
17000.0
19000.0
18000.0
5.0 <
6.9
5.3
12.0
15.0
9.4
1.0
7.3
5.0 <
5.0 <
15.0
6.4
9.3
5.0 <
5.0 <
12.0
8.9
STD. DEV.









1.1
762.7
2600.6
762.5
1437.9
3757.9
229.1
2178.0
2884.3
983.4
1523.8
2861.4
1706.1

3.2
0.4
3.7
8.9
7.7

1.0


0.6
2.0
2.8


0.4
5.4
SPE Disk Values are not blank-corrected since blanks  were  not analyzed for two solvents, and the remaining solvents had blank values < 1 mg/L.
                                                                                    B-10

-------
                                                                             OIL  & GREASE  DATA
                                                                           FREON REPLACEMENT  STUDY
                                                                                  PHASE  I
                                                                                                                      June  21.  1993
                                                                                                                        Page  11 of 25
              FACILITY
  20   MAYONNAISE PLANT
 SCCf

23111
  WASTE STREAM
FILTER EFFLUENT
  TECHNIQUE
LIQ/LIQ (A)
                                 23111

                                 23111
                                 23111
                                 23112
          FILTER EFFLUENT

          FILTER EFFLUENT
          FILTER EFFLUENT
          OILY SLUDGE
                     INFRARED  (A)

                     SPE  DISK  90mm  (A)
                     SPE  DISK  47mm  (A)
                     SONICATION  CS)
                                 23112
          OILY SLUDGE
                     SOXHLET  (S)
  21   SEAFOOD PLANT
23113     SECONDARY EFFLUENT    LIQ/LIQ  (A)
      SOLVENT
                                 23113     SECONDARY  EFFLUENT   INFRARED (A)
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

FLON

METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC

METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

FLON
                                                                                                                         Oil & Grease Concentrations:
                                                                                                                            mg/L in aqueous samples  (A)
                                                                                                                            mg/kg in solid/sludge samples (S)
REP1
17.0
5.0 <
5.5
21.0
16.0
5.0 <
10.0
28.0
5.0 <
5.0 <
35.0
12.0
26.0
5.0 <
5.0 <
27. 0
5.0 <
650000.0
670000.0
480000.0
560000.0
610000.0
370000.0
910000.0
880000.0
590000.0
890000.0
840000.0
860000.0
6.9
5.0 <
18.0
13.0
14.0
5.0 <
2.0
REP2
5.0 <
5.0 <
5.0 <
14.0
18.0
8.7
10.0
33.0
5.0 <
5.0 <
35.0
12.0
27.0
5.6
5.0 <
30.0
6.0
640000.0
760000.0
470000.0
510000.0
580000.0
490000.0
910000.0
850000.0
780000.0
900000.0
660000.0
760000.0
5.0 <
5.0 <
5.0 <
11.0
23.0
5.0 <
2.0
REPS
20.0
5.0 <
100.0
8.3
16.0
5.0 <











740000.0
160000.0
360000.0
510000.0
460000.0
570000.0
940000.0
780000.0
520000.0
870000.0
670000.0
800000.0
5.0 <
47.0
27.0
28.0
13.0
5.0 <

MEAN
14.0
5.0 <
38.0
15.0
16.0
6.2
10.0
31.0
5.0 <
5.0 <
35.0
12.0
26.0
5.3
5.0 <
28.0
5.5
680000.0
530000.0
440000.0
520000.0
550000.0
470000.0
920000.0
840000.0
630000.0
890000.0
720000.0
800000.0
5.6
19.0
17.0
17.0
17.0
5.0 <
2.0
STD. DEV.
7.9

56.1
6.6
1.1
2.1
0.1
4.0


0.1
0.1
0.8
0.4

2.1
0.7
57133.5
319216.2
68563.8
29194.7
80727.9
97495.3
18770.5
50520.6
132020.2
15044.4
99926.6
51791.2
1.1
24.4
11.1
9.4
5.3


SPt Disk Values are not blank-corrected since  blanks were not analyzed for two solvents, and the remaining solvents had blank values < 1 mg/L.

                                                                                    B-ll

-------
                                                                             OIL & GREASE DATA
                                                                          FREON REPLACEMENT STUDY
                                                                                  PHASE I
                                                                                                                      June 21, 1993
                                                                                                                        Page 12 of 25
             FACILITY
 SCCI


23113





23113





23114
                                            WASTE STREAM
                      TECHNIQUE
                                          SECONDARY EFFLUENT   SPE DISK 90mm (A)
                                          SECONDARY EFFLUENT   SPE DISK 47mm (A)
                                          WASTE SLUDGE
                     SONICATION  (S)
                                 23114
          WASTE SLUDGE
                     SOXHLET  (S)
  22    ABRASIVES PLANT
23115
                                 23115
                                 23115
PROCESS WASTEWATER   LIQ/LIQ  (A)
          PROCESS WASTEWATER   SPE DISK 90mm (A)
          PROCESS WASTEWATER   SPE DISK 47mm (A)
      SOLVENT
METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC

METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

DUPONT123
FREON
METHYLENE CHLORIDE
PERCHLOR
80/20

METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC

METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC
                                                                                                                         Oil & Grease Concentrations:
                                                                                                                            mg/L in aqueous samples (A)
                                                                                                                            mg/kq in solid/sludge samples
                                                                                                                          (S)
REP1
6.7
5.0 <
5.0 <
9.3
5.0 <
6.8
5.0 <
5.0 <
7.8
6.4
77000.0
74000.0
0.0
59000.0
57000.0
46000.0
350000.0
64000.0
34000.0
7900.0
35000.0
14000.0
5.0 <
9.2
14.0
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
REP2
6.6
5.0 <
5.0 <
9.8
5.0 <
8.6
5.0 <
5.0 <
11.0
5.0 <
5600.0
14000.0
21000.0
68000.0
83000.0
32000.0
170000.0

31000.0
64000.0
36000.0
28000.0
5.0 <
27 0
21.0
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
5.9
5.0 <
REP3










74000.0
28000.0
36000.0
62000.0
62000.0
48000.0
180000.0
53000.0
27000.0
39000.0
12000.0
94000.0
5.0 <
5.0 <
5.0 <
5.0 <
5.7










MEAN
6.7
5.0 <
5.0 <
9.6
5.0 <
7.7
5.0 <
5.0 <
9.5
5.7
52000.0
39000.0
19000.0
63000.0
67000.0
42000.0
230000.0
58000.0
31000.0
37000.0
28000.0
45000.0
5.0 <
14.0
13.0
5.0 <
5.2
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
5.5
5.0 <
STD. DEV.
0.1


0.4

1.3


2.4
1.0
40342.5
31219.4
17989.7
4535.1
14065.4
8923.1
100583 3
7525.9
3867.0
28005.2
13882.9
42738.5

11.6
8.0

0.4








0.6

SPE Disk Values are not blank-corrected since blanks  were  not  analyzed for two solvents, and the remaining solvents had blank values < 1 mg/L.

-------
                                                                              OIL & GREASE DATA
                                                                           FREON REPLACEMENT STUDY
                                                                                   PHASE I
                                                                                                                      June 21. 1993
                                                                                                                        Page 13 of 25
              FACILITY
  23   OIL TERMINAL
 SCCI

23120
  WASTE STREAM
  TECHNIQUE
SEPARATOR EFFLUENT   LIQ/LIQ (A)
  24   SEAFOOD PLANT
                                 23120

                                 23120
                                 23120
                                 23120
23121
          SEPARATOR EFFLUENT

          SEPARATOR EFFLUENT
                     INFRARED (A)

                     SPE DISK 90mm (A)
          SEPARATOR EFFLUENT   SPE  DISK 47mm  (A)
          SEPARATOR EFFLUENT   SPE  COLUMN  II  (A)
PRIMARY EFFLUENT
LIQ/LIQ (A)
                                 23121

                                 23121
                                 23121
          PRIMARY EFFLUENT

          PRIMARY EFFLUENT
          PRIMARY EFFLUENT
                     INFRARED (A)

                     SPE DISK 90mm (A)
                     SPE DISK 47mm (A)
      SOLVENT
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

FLON

METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC

METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC

FREON
HEXANE
80/20

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

FLON

METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC

METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC
                                                                                                                          Oil  & Grease Concentrations:
                                                                                                                             mg/L  in  aqueous  samples  (A)
                                                                                                                             rcg/kg in solid/sludge samples  (S)
REP1
7.0
5.0 <
6.0
12.0
8.0
5.0 <
3.2
11.0
5.0 <
5.0 <
17.0
5.7
19.0
7.3
5.0 <
23.0
13.0
5.0 <
8.0
7.0
16.0
14.0
21.0
37.0
28.0
11.0
40.0
44.0
11.0
17.0
57.0
20.0
60.0
11.0
18.0
63.0
24.0
REP2
6.0
5.0 <
5.0 <
13.0
14.0
5.0 <
3.3
9.2
5.0 <
5.0 <
17.0
5.5
17.0
9.2
5.5
23.0
12.0
7.0
8.0
5.0 <
17.0
14.0
20.0
29.0
24.0
11.0
33.0
43.0
10.0
23.0
56.0
21.0
58.0
13.0
19.0
65.0
25.0
REPS
9.0
6.0
5.0 <
9.0
5.0 <
5.0 <














13.0
13.0
17.0
38.0
19.0
11.0











MEAN
7.3
5.3
5.3
11.0
9.0
5.0 <
3.3
10.0
5.0 <
5.0 <
17.0
5.6
18.0
8.3
5.3
23.0
13.0
6.0
8.0
6.0
15.0
14.0
19.0
35.0
24.0
11.0
36.0
44.0
11.0
20.0
56.0
20.0
59.0
12.0
18.0
64.0
24.0
STD. DEV.
1.5
0.6
0.6
2.1
4.6

0.1
1.3


0.2
0.1
1.4
1.3
0.4
0.2
0.4
1.4

1.4
2.2
0.6
1.9
4.9
4.7
0.2
4.7
0.7
0.5
4.0
1.1
0.4
1.8
1.3
0.9
1.3
0.4
SPE Disk Values are not blank-corrected since blanks  were  not analyzed  for two solvents,  and the  remaining  solvents had  blank  values  <  1 mg/L.
                                                                                    B-13

-------
                                                                              OIL & GREASE DATA
                                                                           FREON REPLACEMENT STUDY
                                                                                   PHASE I
                                                                                                                       June 21.  1993
                                                                                                                         Page 14 of 25
              FACILITY
 SCCI
23121

23122
  WASTE STREAM
                                           PRIMARY EFFLUENT
                                           OILY SLUDGE
  TECHNIQUE
SPE COLUMN II (A)
                     SONICATION  (S)
                                 23122
          OILY SLUDGE
                     SOXHLET (S)
                                 23123
          DEWATERED SLUDGE
                     SOXHLET (S)
  25   POULTRY PLANT
23457
DAF INFLUENT
LIQ/LIQ (A)
                                 23457
                                 23457
                                 23457
          DAF INFLUENT
          DAF INFLUENT
          DAF INFLUENT
                     INFRARED  (A)
                     SPE  DISK  90mm  (A)
                     SPE  DISK 47mm  (A)
                                                                                                                          Oil & Grease Concentrations:
                                                                                                                             mg/L in aqueous samples (A)
                                                                                                                             mq/kq in solid/sludge samples (S)
SOLVENT
FREON
HEXANE
80/20
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
FLON
METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC
METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC
REP1
13.0
7.0
13.0
490000.0
340000.0
300000.0
420000.0
470000.0
320000.0
360000.0
400000.0
400000.0
520000.0
400000.0
440000.0
24000.0
31000.0
220000.0
220000.0
380000.0
250000 0
340.0
730.0
530.0
420.0
820.0
400.0
24.0
1700.0
700.0
700.0
850.0
870.0
1000.0
900.0
890.0
830.0
1000.0
REP2
11.0
8.0
7.0
420000.0
310000.0
330000.0
400000.0
530000.0
340000.0
400000.0
410000.0
390000.0
570000.0
390000.0
420000.0
27000.0
27000.0
150000.0
260000.0
280000.0
220000.0
340.0
630.0
600.0
400.0
990.0
440.0
27.0
1700.0
840.0
770.0
830.0
950.0
970.0
910.0
850.0
1000.0
910.0
REPS



410000.0
300000.0
300000.0
410000.0
410000.0
330000.0
320000.0
430000.0
390000.0
620000.0
300000.0
420000.0
23000.0
31000.0
200000.0
210000.0
440000.0
210000.0
330.0
650.0
680.0
430.0
870.0
290.0











MEAN
12.0
7.5
10.0
440000.0
320000.0
310000.0
410000.0
470000.0
330000.0
360000.0
410000.0
400000.0
570000.0
370000.0
430000.0
25000.0
29000.0
190000.0
230000.0
370000.0
230000 0
330.0
670.0
610.0
420.0
890.0
370.0
25.0
1700.0
770.0
740.0
840.0
910.0
980.0
900.0
870.0
920.0
960.0
STD. DEV.
1.4
0.7
4.2
42673.2
20108 0
17616.3
6806.9
63500.7
8621.7
37527.8
16370.7
7094.6
48507.7
57873 4
10116.0
2022.4
2285.5
36295 1
25534.3
79567.6
20792.6
7 6
54.1
74.7
12.8
90.7
79.0
2.2
0.7
99.7
48.1
14.1
57.3
24.0
3.5
26.9
125.2
72.8
SPE Disk Values are not blank-corrected since blanks were not analyzed  for  two  solvents,  and the remaining solvents had blank values < 1 mg/L.
                                                                                     B-14

-------
                                                                              OIL & GREASE DATA
                                                                           FREON REPLACEMENT STUDY
                                                                                   PHASE  I
                                                                                                                      June 21,  1993
                                                                                                                         Page  15 of 25
              FACILITY
            WASTE STREAM
                                           DAF SLUDGE
                       TECHNIQUE
                               SONICATION (S)
                                 23458
          DAF SLUDGE
                     SOXHLET (S)
  26   MEAT PACKING PLANT
23124
LAGOON EFFLUENT
LIQ/LIQ (A)
  27   RAILROAD YARD
                                 23124
                                 23124
                                 23124
                                 23124
23459
          LAGOON EFFLUENT
          LAGOON EFFLUENT
          LAGOON EFFLUENT
          LAGOON EFFLUENT
DAF EFFLUENT
                     INFRARED (A)
                     SPE DISK 90mm (A)
                     SPE DISK 47mm (A)
                     SPE COLUMN II (A)
LIQ/LIQ (A)
                                                                                                                          Oil & Grease Concentrations:
                                                                                                                             mg/L in aqueous samples  (A)
                                                                                                                             mg/kg in solid/sludge samples (S)
SOLVENT
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
FLON
METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC
METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC
FREON
HEXANE
80/20
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
REP1
170000.0
190000.0
130000.0
190000.0
320000.0
140000.0
590000.0
670000.0
530000.0
580000.0
690000.0
610000.0
12.0
11.0
15.0
39.0
51.0
110.0
87.0
17.0
11 0
13.0
21.0
9.3
39.0
5.0 <
28.0
61.0
13.0
7.0
20.0
14.0
34.0
170.0
91.0
54.0
170.0
140.0
REP2
210000.0
160000.0
85000.0
150000.0
390000.0
140000.0
570000.0
600000.0
530000.0
540000.0
450000.0
430000.0
16.0
13.0
12.0
43.0
52.0
25.0
88.0
11.0
11.0
13.0
22.0
10.0
38.0
5.0 <
26.0
66.0
13.0
5.0 <
13.0
17.0
30.0
120.0
110.0
62.0
240.0
150.0
REPS
240000.0
190000.0
92000.0
170000.0
330000.0
70000.0
580000.0
570000.0
530000 0
530000 0
530000.0
550000.0
17.0
14.0
15.0
39.0
58.0
26.0














69.0
190.0
81.0
42.0
250.0
150.0
MEAN
200000.0
180000.0
100000.0
170000.0
350000.0
120000.0
580000.0
610000.0
530000.0
550000.0
560000.0
530000.0
15.0
13.0
14.0
40.0
54.0
55.0
87.0
14.0
11.0
13.0
22.0
9.8
38.0
5.0 <
27.0
63.0
13.0
6.0
17.0
16.0
44.0
160.0
93.0
53.0
220.0
140.0
STD. DEV.
36721.9
14298.1
22482.0
21072.8
39362.0
40578.7
7019.6
49549.3
2449.0
22853.1
120291.7
88521.9
2.6
1.4
1.8
2.0
3.9
50.7
0 8
4.2

0.3
0.8
0.7
0.9

1.5
3.7
0.5
1.4
4.9
2.1
21.2
36.1
13.3
10.1
43.3
6.7
SPE Disk Values are not blank-corrected since blanks  were not  analyzed  for  two solvents,  and the remaining solvents had blank values < 1 mg/L.
                                                                                     B-15

-------
                                                                             OIL & GREASE  DATA
                                                                           FREON REPLACEMENT  STUDY
                                                                                  PHASE  I
                                                                                                                      June 21.  1993
                                                                                                                        Page  16 of 25
              FACILITY
 SCCI
23459
23459
                                 23459
                                 23460
  UASTE STREAM
DAF EFFLUENT
DAF EFFLUENT
          DAF EFFLUENT
          OILY SLUDGE
  TECHNIQUE
INFRARED (A)
SPE DISK 90mm (A)
                     SPE DISK 47mm (A)
                     SONICATION (S)
                                 23460
          OILY SLUDGE
                     SOXHLET (S)
  28   CAN MANUFACT PLANT
23461
PRIMARY EFFLUENT
LIQ/LIQ (A)
                                 23461
                                 23461
          PRIMARY EFFLUENT
          PRIMARY EFFLUENT
                     INFRARED (A)
                     SPE DISK 90mm (A)
                                                                                                                         Oil & Grease  Concentrations:
                                                                                                                            mg/L  in aquepus  samples  (A)
                                                                                                                            mq/kq in solid/sludge  samples  (S)
SOLVENT
FLON
METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC
METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
FLON
METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC
REP1
400.0
80.0
83.0
57.0
150.0
53.0
330.0
66.0
210.0
430.0
91.0
290000.0
380000.0
250000.0
350000.0
400000.0
160000.0
790000.0
870000.0
850000.0
800000.0
1000000.0
860000.0
400.0
220.0
180.0
340.0
400.0
190.0
230.0
390.0
370.0
250.0
420.0
360.0
REP2
380.0
96.0
48.0
39.0
160.0
58.0
360.0
88.0
230.0
440.0
95.0
480000.0
380000.0
110000.0
320000.0
410000.0
310000.0
790000.0
920000.0
840000.0
800000.0
1000000.0
860000.0
390.0
220.0
180.0
360.0
390.0
190.0
230.0
360.0
370.0
300.0
430.0
360.0
REPS











520000.0
450000.0
200000.0
190000.0
410000.0
310000.0
670000.0
870000.0
830000.0
800000.0
930000.0
750000.0
350.0
220.0
170.0
370.0
390.0
190.0






MEAN
390.0
88.0
66.0
48.0
160.0
56.0
340.0
77.0
220.0
440.0
93.0
430000.0
400000.0
190000.0
290000.0
410000.0
260000.0
750000.0
890000.0
840000.0
800000.0
990000.0
820000.0
380.0
220.0
180.0
360.0
390.0
190.0
230.0
380.0
370.0
270.0
420.0
360.0
STD. DEV.
12.7
11.5
24.7
13.1
8.5
3.6
17.0
15.1
15.6
6.4
2.5
123939.1
37435.9
68359.5
83973.2
3281.3
85200.8
68154.5
27906.0
6884.3
3722.0
52451.3
60549.2
23.4
2.9
5.5
13.4
3.2
4.1
1.4
19.1
0.7
37.5
7.8
2.1
SPE Disk Values are not blank-corrected since blanks were not  analyzed  for two solvents, and the  remaining  solvents  had  blank  values  <  1 mg/L.
                                                                                    B-16

-------
                                                                              OIL & GREASE DATA
                                                                           FREON REPLACEMENT STUDY
                                                                                   PHASE I
                                                                                                                      June 21, 1993
                                                                                                                        Page 17 of 25
              FACILITY
_SCCJ

23461





23461



23462
  WASTE STREAM
                                           PRIMARY EFFLUENT
                                           PRIMARY EFFLUENT
                                           FILTER CAKE
  TECHNIQUE

SPE DISK 47mm (A)
                     SPE  COLUMN  II  (A)
                     SONICATION  (S)
                                 23462
          FILTER CAKE
                     SOXHLET  (S)
  29   SOUP PLANT
23466
DAF EFFLUENT
LIQ/LIQ (A)
                                 23466

                                 23466
                                 23466
          DAF EFFLUENT

          DAF EFFLUENT
          DAF EFFLUENT
                     INFRARED  (A)

                     SPE  DISK  90mm  (A)
                     SPE  DISK 47mm  (A)
      SOLVENT
METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC

FREON
HEXANE
80/20

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

FLON

METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC

METHYLENE CHLORIDE
FREON
HEXANE
MTPE
PERC
                                                                                                                          Oil  & Grease Concentrations:
                                                                                                                             mg/L in aqueous samples  (A)
                                                                                                                             mq/kq In solid/sludge samples  (S)
REP1
500.0
410.0
370.0
510.0
450.0
290.0
220.0
320.0
43000.0
42000.0
31000.0
51000.0
61000.0
27000.0
40000.0
62000.0
69000.0
74000.0
71000.0
67000.0
5.0 <
5.4
5.0 <
5.0 <
5.1
5.0 <
3.2
9.8
6.0
7.8
11.0
6.4
17.0
6.9
6.8
23.0
13.0
REP2
450.0
360.0
370.0
500.0
470.0
270.0
190.0
340.0
25000.0
38000.0
36000.0
48000.0
72000.0
30000.0
61000.0
62000.0
64000.0
72000.0
85000.0
65000.0
6.7
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
2.9
9.0
7.3
7.1
10.0
6.9
21.0
8.9
9.4
15.0
17.0
REPS








42000.0
34000.0
38000.0
46000.0
44000.0
39000.0
60000.0
60000.0
66000.0
74000.0
68000.0
69000.0
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <











MEAN
470.0
380.0
370.0
500.0
460.0
280.0
200.0
330.0
37000.0
38000.0
35000.0
48000.0
59000.0
32000.0
53000.0
61000.0
66000.0
73000.0
75000.0
67000.0
5.6
5.1
5.0 <
5.0 <
5.0 <
5.0 <
3.1
9.4
6.7
7.5
10.0
6.7
19.0
7.9
8.1
19.0
15.0
STD. DEV.
37.5
29.7
3.5
3.5
14.1
14.1
16.3
15.6
10167.0
4175.8
3749.6
2486.4
14050.6
6014.5
11630.8
976.2
2615.1
927.7
9239.2
1791.8
1.0
0.2


0.1

0.2
0.6
0.9
0.5
0.6
0.4
2.5
1.4
1.8
5.8
2.9
SPE Disk Values are not blank-corrected since blanks  were  not analyzed for two solvents, and the  remaining  solvents  had blank  values <  1 mg/L.
                                                                                    B-17

-------
                                                                              OIL & GREASE DATA
                                                                           FREON REPLACEMENT STUDY
                                                                                   PHASE  I
                                                                                                             June  21,  1993
                                                                                                               Page  18 of 25
              FACILITY            SCCI


                                 23466



                                 23467
  UASTE STREAM
DAF EFFLUENT
DAF SLUDGE
  TECHNIQUE


SPE COLUMN II (A)
SONICATION (S)
                                 23467
DAF SLUDGE
SOXHLET (S)
  30   OILY WATER TREAT PLANT    23468     SEPARATOR EFFLUENT   LIQ/LIQ (A)
                                 23468

                                 23468
                                 23468
SEPARATOR EFFLUENT

SEPARATOR EFFLUENT
INFRARED (A)

SPE DISK 90mm (A)
SEPARATOR EFFLUENT   SPE  DISK  47mm  (A)
                                 23468     SEPARATOR EFFLUENT   SPE  COLUMN  II  (A)
                                                                                                                          Oil & Grease Concentrations:
                                                                                                                             mg/L in aqueous samples  (A)
                                                                                                                             mg/kg in solid/sludge samples  (S)
SOLVENT
FREON
HEXANE
80/20
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
FLON
METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC
METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC
FREON
HEXANE
80/20
REP1
5.0 <
11.0
6.0
580000.0
580000.0
560000.0
650000.0
550000.0
580000.0
620000.0
600000.0
580000.0
650000.0
700000.0
640000.0
23.0
29.0
16.0
22.0
16.0
11.0
24.0
17.0
9.0
11.0
30.0
13.0
39.0
34.0
38.0
18.0
46.0
9.0
23.0
14.0
REP2
5.0 <
5.0 <
7.0
650000.0
630000.0
550000.0
630000.0
620000.0
580000.0
610000.0
590000.0
520000.0
630000.0
740000.0
670000.0
26.0
27.0
21.0
24.0
32.0
15.0
27.0
14.0
9.1
8.3
22.0
8.3
44.0
36.0
42.0
15.0
40.0
9.0
29.0
16.0
REPS



620000.0
650000.0
540000.0
620000.0
590000.0
590000.0
600000.0
610000.0
600000.0
720000.0
740000.0
650000.0
25.0
28.0
29 0
21.0
13.0
16.0














MEAN
5.0 <
8.0
6.5
610000.0
620000.0
550000.0
630000.0
580000.0
590000.0
610000.0
600000.0
570000.0
660000.0
730000.0
650000.0
24.0
28.0
22.0
22.0
20.0
14.0
25.0
16.0
9.1
9.4
26.0
11.0
42.0
35.0
40.0
16.0
43.0
9.0
26.0
15.0
STD. DEV.

4.2
0.7
34703.5
33709.5
13576.9
16258.3
36115.6
6245.0
8504.9
10066.4
40360.9
47318.1
24433.6
15099.7
1.9
1.0
6.2
1.6
10.0
2.8
2.2
1.8
0.1
1.6
5.7
3.5
3.9
1.7
2.8
1.9
4.2

4.2
1.4
SPt Disk Values are not blank-corrected since blanks were not analyzed  for two solvents,  and  the  remaining  solvents  had  blank  values  <  1  mg/L.

                                                                                    B-18

-------
                                                                              OIL & GREASE DATA
                                                                           FREON REPLACEMENT STUDY
                                                                                   PHASE I
                                                                                                                      June 21.  1993
                                                                                                                        Page 19 of 25
              FACILITY
 SCC#

23469
  WASTE STREAM
                                           OILY SLUDGE
  TECHNIQUE

SONICATION (S)
                                 23469
          OILY SLUDGE
                     SOXHLET  (S)
  31   CAN MANUFACT PLANT
23470
DAF INFLUENT
LIQ/LIQ (A)
                                 23470

                                 23470
                                 23470
                                 23471
          DAF INFLUENT

          DAF INFLUENT
          DAF INFLUENT
          OILY  SLUDGE
                     INFRARED  (A)

                     SPE  DISK  90mm  (A)
                     SPE  DISK 47mm  (A)
                     SONICATION  (S)
      SOLVENT
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

FLON

METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC

METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
                                                                                                                          Oil  & Grease Concentrations:
                                                                                                                            mg/L  in  aqueous  samples  (A)
                                                                                                                            mq/kg in solid/sludge samples  (S)
REP1
43000.0
60000.0
16000.0
43000.0
52000.0
65000.0
91000.0
76000.0
77000.0
77000.0
85000.0
82000.0
350.0
360.0
320.0
370.0
380.0
370.0
290.0
450.0
410.0
370.0
440.0
430.0
480.0
300.0
410.0
510.0
460.0
64000.0
59000.0
67000.0
43000.0
62000.0
70000.0
REP2
58000.0
52000.0
32000.0
63000.0
62000.0
46000.0
99000.0
75000.0
60000.0
79000.0
91000.0
86000.0
360.0
340.0
410.0
390.0
390.0
360.0
280.0
410.0
400.0
350.0
440.0
410.0
450.0
420.0
410.0
460.0
470.0
61000.0
69000.0
45000.0
23000.0
64000.0
51000.0
REPS
51000.0
43000.0
37000.0
60000.0
23000.0
58000.0
110000.0
70000.0
79000.0
76000.0
100000.0
84000.0
400.0
350.0
470.0
350.0
420.0
320.0











65000.0
74000.0
46000.0
35000.0
70000.0
67000.0
MEAN
51000.0
51000.0
28000.0
55000.0
46000.0
56000.0
100000.0
74000.0
72000.0
77000.0
92000.0
84000.0
370.0
350.0
400.0
370.0
390.0
350.0
290.0
430.0
410.0
360.0
440.0
420.0
470.0
360.0
410.0
480.0
460.0
63000.0
67000.0
53000.0
34000.0
65000.0
62000.0
STD. DEV.
7650.6
8431.0
11093.8
10772.3
20211.1
9559.5
10159.8
3214.6
10712.9
1414.8
7886.5
2099.4
26.7
8.9
75.5
19.9
19.2
29.8
7.8
21.9
8.5
12.7
4.9
12.0
18.4
81.3
0.7
36.1
6.4
2086.2
7407.7
12097.0
10135.4
4477.1
10181.4
SPL- Disk Values are not blank-corrected since blanks were not analyzed for two solvents, and the  remaining solvents had blank values < 1 mg/L.
                                                                                    B-19

-------
                                                                              OIL & GREASE DATA
                                                                           FREON REPLACEMENT STUDY
                                                                                   PHASE I
                                                                                                                      June  21.  1993
                                                                                                                         Page  20 of 25
              FACILITY
 SCCI
23471
  WASTE STREAM
                                           OILY SLUDGE
  TECHNIQUE
                     SOXHLET (S)
  32   CAN MANUFACT PLANT
23472
OAF EFFLUENT
LIQ/LIQ (A)
                                 23472
                                 23472
                                 23472
                                 23472
                                 23473
          DAF EFFLUENT
          DAF EFFLUENT
          DAF EFFLUENT
          DAF EFFLUENT
          DAF INFLUENT
                     INFRARED (A)
                     SPE DISK 90mm (A)
                     SPE DISK 47mm (A)
                     SPE COLUMN II  (A)
                     LIQ/LIQ (A)
                                                                                                                          Oil  & Grease Concentrations:
                                                                                                                             mg/L in aqueous samples (A)
                                                                                                                             mq/kg in solid/sludge samples (S)
SOLVENT
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
FLON
METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC
METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC
FREON
HEXANE
80/20
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
REP1
92000.0
94000.0
80000.0
96000.0
120000.0
110000.0
34.0
9.0
5.0 <
35.0
19.0
6.2
8.3
65.0
9.2
8.1
58.0
22.0
110.0
35.0
38.0
65.0
51.0
7.0
5.0 <
30.0
480.0
430.0
310.0
420.0
570.0
360.0
REP2
95000.0
88000.0
90000.0
110000.0
120000.0
110000.0
33.0
16.0
5 0 <
34.0
27.0
6.7
8 8
68.0
12.0
6.0
63.0
21.0
100.0
34.0
43.0
71.0
58.0
9.0
7.0
27.0
440.0
410.0
340.0
440.0
560.0
340.0
REPS
89000.0
94000.0
83000.0
92000.0
100000.0
100000.0
35.0
16.0
5.5
34.0
24.0
7.5














450.0
360.0
350.0
400.0
460.0
350.0
MEAN
92000.0
92000.0
85000.0
98000.0
120000.0
110000.0
34.0
14.0
5.2
34.0
23.0
6.8
8.6
66.0
11.0
7.1
60.0
21.0
110.0
35.0
41.0
68.0
55.0
8.0
6.0
29.0
460.0
400.0
330.0
420.0
530.0
350.0
STD. DEV.
2998.2
3291.2
4991.8
7734.3
12649.4
1719.8
0.9
3.9
0.3
0.7
4.2
0.7
0.4
1.8
2.2
1.5
4.0
0.4
4.2
1.0
3.5
3.9
4.6
1.4
1.4
2.1
19.3
33.8
21.5
20.6
59.0
8.1
                                 23473
          DAF INFLUENT
                     INFRARED (A)
                   FLON
150.0
140.0
150.0
5.7
SPE Disk Values are not blank-corrected since blanks were not analyzed  for two solvents, and  the  remaining  solvents  had  blank  values  <  1  mg/L.
                                                                                    B-20

-------
                                                                              OIL & GREASE DATA
                                                                           FREON REPLACEMENT STUDY
                                                                                   PHASE I
                                                                                                                      June 21,  1993
                                                                                                                        Page 21 of 25
              FACILITY
 SCC#       WASTE STREAM


23473     DAF INFLUENT





23473     DAF INFLUENT





23473     DAF INFLUENT



23474     FILTER CAKE
  TECHNIQUE
                                                                SPE  DISK 90mm (A)
                                                                SPE DISK 47mm (A)
                                                                SPE  COLUMN  II  (A)
                                                                SONICATION  (S)
                                 23474     FILTER CAKE
                               SOXHLET  (S)
  33   DRUM HANDLING FACILITY    23475
          FILTER EFFLUENT
LIQ/LIQ (A)
                                 23475

                                 23475
          FILTER EFFLUENT

          FILTER EFFLUENT
INFRARED (A)

SPE DISK 90mm (A)
                                                                                         SOLVENT
METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC

METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC

FREON
HEXANE
80/20

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

FLON

METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC
                                                                                                                          Oil  & Grease Concentrations:
                                                                                                                             mg/L in aqueous samples (A)
                                                                                                                             mg/kg in solid/sludge samples (S)
REP1
470.0
420.0
430.0
470.0
520.0
630.0
490.0
510.0
510.0
560.0
470.0
470.0
500.0
96000.0
120000.0
190000.0
86000.0
200000.0
180000.0
310000.0
290000.0
290000.0
310000.0
260000.0
300000.0
230.0
140.0
110.0
310.0
180.0
140.0
110.0
150.0
36.0
57.0
110.0
62.0
REP2
460.0
410.0
410.0
500.0
520.0
520.0
480.0
500.0
490.0
560.0
250.0
460.0
450.0
120000.0
110000.0
200000.0
130000.0
190000.0
190000.0
310000.0
290000.0
290000.0
320000.0
390000.0
290000.0
220.0
130.0
98.0
290.0
180.0
140.0
110.0
130.0
43.0
48.0
110.0
66.0
REPS













81000.0
120000.0
180000.0
110000.0
230000.0
180000.0
310000.0
300000.0
290000.0
270000.0
300000.0
290000.0
170.0
130.0
130.0
320.0
190.0
150.0






MEAN
470.0
420.0
420.0
480.0
520.0
580.0
480.0
510.0
500.0
560.0
360.0
470.0
480.0
100000.0
120000.0
190000.0
110000.0
210000.0
180000.0
310000.0
290000.0
290000.0
300000.0
320000.0
290000.0
210.0
130.0
110.0
310.0
180.0
150.0
110.0
140.0
40.0
53.0
110.0
64.0
STD. DEV.
8.5
7.8
11.3
21.9
4.2
80.6
10.6
2.1
16.3
1.4
157.7
7.1
31.8
21559.9
7177.7
10923.2
20643.2
18781.7
6847.2
3104.1
6217.5
2029.0
25951.7
65215.3
6203.2
31.4
6.6
15.3
13.7
5.5
2.6
5.7
9.9
4.7
5.9
4.2
2.7
SPE Disk Values are not blank-corrected since blanks  were  not  analyzed for two solvents,  and the  remaining  solvents had blank  values <  1 mg/L.

                                                                                    B-21

-------
                                                                             OIL & GREASE  DATA
                                                                           FREON REPLACEMENT  STUDY
                                                                                  PHASE  I
                                                                                                                      June 21, 1993
                                                                                                                        Page 22 of 25
                                                                                                                         Oil & Grease Concentrations:
                                                                                                                            mg/L in aqueous samples  (A)
                                                                                                                            mq/kq in solid/sludge samples (S)
              FACILITY
_SCCf

23475





23475



23476




23476
  WASTE STREAM
                                           FILTER EFFLUENT
                                           FILTER EFFLUENT
                                           OILY SLUDGE
                                           OILY SLUDGE
TECHNIQUE
                     SPE DISK 47mm  (A)
                     SPE  COLUMN  II  (A)
                     SONICATION  (S)
                     SOXHLET  (S)
  34   POLYMER PLANT
23477
SECONDARY EFFLUENT   LIQ/LIQ  (A)
                                 23477

                                 23477
                                 23477
                                 23477
          SECONDARY EFFLUENT

          SECONDARY EFFLUENT
                     INFRARED  (A)

                     SPE DISK  90mm  (A)
          SECONDARY EFFLUENT   SPE DISK 47mm  (A)
          SECONDARY EFFLUENT   SPE COLUMN  II  (A)
SOLVENT
                 METHYLENE CHLORIDE
                 FREON
                 HEXANE
                 MTBE
                 PERC

                 FREON
                 HEXANE
                 80/20

                 FREON
                 HEXANE
                 PERCHLOR
                 80/20

                 DUPONT123
                 FREON
                 HEXANE
                 METHYLENE CHLORIDE
                 PERCHLOR
                 80/20

                 DUPONT123
                 FREON
                 HEXANE
                 METHYLENE CHLORIDE
                 PERCHLOR
                 80/20

                 FLON

                 METHYLENE CHLORIDE
                 FREON
                 HEXANE
                 MTBE
                 PERC

                 METHYLENE CHLORIDE
                 FREON
                 HEXANE
                 MTBE
                 PERC

                 FREON
                 HEXANE
                 80/20
REP1
160.0
42.0
67.0
120.0
110.0
65.0
150.0
230.0
1000000.0
860000.0
1200000.0
890000.0
1200000.0
1200000.0
990000.0
1000000.0
810000.0
800000.0
5.0 <
6.4
5.0 <
5.0 <
5.0 <
5.0 <
4.0
7.4
16.0
14.0
22.0
7.6
16.0
57.0
40.0
86.0
30.0
5.0 <
5.0 <
5.0 <
REP2
150.0
40.0
68.0
150.0
89.0
46.0
84.0
250.0
1000000.0
820000.0
1200000.0
730000.0
980000.0
1100000.0
1000000.0
1200000.0
850000.0
840000.0
5.0 <
5.0 <
5.0 <
5.0 <
5.0 <
7.5
4.0
6.4
7.6
14.0
25.0
7.7
14.0
54.0
49.0
91.0
29.0
5.0 <
5.0 <
5.0 <
REPS








970000.0
960000.0
1100000.0
810000.0
1100000.0
1200000.0
980000.0
1000000.0
830000.0
780000.0
5.0 <
14.0
5.0 <
5.0 <
5.0 <
5.0 <














MEAN
150.0
41.0
68.0
130.0
99.0
56.0
120.0
240.0
1000000.0
880000.0
1200000.0
810000.0
1100000.0
1200000.0
1000000.0
1100000.0
830000.0
810000.0
5.0 <
8.3
5.0 <
5.0 <
5.0 <
5.8
4.0
6.9
12.0
14.0
24.0
7.7
15.0
55.0
44.0
88.0
30.0
5.0 <
5.0 <
5.0 <
STD. DEV.
6.4
1.3
0.9
16.3
14.4
13.4
48.8
12.0
71174.7
73646.2
38349.5
79642 6
100976 9
57735.0
27319.1
94516.3
24062.4
28160.2

4.6



1.4

0.7
6.2
0.2
2.2
0.1
1.4
2.3
6.6
3.6
0.4



SPE Disk Values are not blank-corrected since blanks  were not analyzed for two solvents, and the remaining solvents had blank values < 1 mg/L.
                                                                                    B-22

-------
                                                                             OIL & GREASE DATA
                                                                          FREON REPLACEMENT  STUDY
                                                                                  PHASE  I
                                                                                                                      June 21. 1993
                                                                                                                        Page 23 of 25
              FACILITY
 SCC#

23478
  WASTE  STREAM
TECHNIQUE
                                          DEWATERED SLUDGE     SONICATION (S)
                                 23478
          DEWATERED SLUDGE      SOXHLET (S)
  35   RESTAURANT
23125
VEGETABLE OIL  WASTE   SONICATION  (S)
                                 23125
          VEGETABLE OIL WASTE  SOXHLET (S)
  36   INDUSTRIAL LAUNDRY
23480
PRIMARY EFFLUENT     LIQ/LIQ (A)
                                 23480

                                 23480
          PRIMARY EFFLUENT

          PRIMARY EFFLUENT
                     INFRARED (A)

                     SPE DISK 90mm (A)
SOLVENT
                 DUPONT123
                 FREON
                 HEXANE
                 METHYLENE CHLORIDE
                 PERCHLOR
                 80/20

                 DUPONT123
                 FREON
                 HEXANE
                 METHYLENE CHLORIDE
                 PERCHLOR
                 80/20

                 DUPONT123
                 FREON
                 HEXANE
                 METHYLENE CHLORIDE
                 PERCHLOR
                 80/20

                 DUPONT123
                 FREON
                 HEXANE
                 METHYLENE CHLORIDE
                 PERCHLOR
                 80/20

                 DUPONT123
                 FREON
                 HEXANE
                 METHYLENE CHLORIDE
                 PERCHLOR
                 80/20

                 FLON

                 METHYLENE CHLORIDE
                 FREON
                 HEXANE
                 MTBE
                 PERC
                                                                                                                         Oil & Grease Concentrations:
                                                                                                                            mg/L in aqueous samples  (A)
                                                                                                                            mg/kq in solid/sludge samples  (S)
REP1
28000.0
7100.0
1800.0
13000.0
23000.0
4200.0
31000.0
13000.0
8400.0
36000.0
26000.0
15000.0
790000.0
740000.0
930000.0
740000.0
850000.0
940000.0
930000.0
760000.0
1100000.0
960000.0
1000000.0
970000.0
250.0
180.0
120.0
170.0
230.0
110.0
190.0
230.0
190.0
190.0
270.0
200.0
REP2
23000.0
3400.0
1900.0
21000.0
15000.0
5500.0
33000.0
12000.0
6900.0
34000.0
28000.0
21000.0
840000.0
960000.0
950000.0
810000.0
950000.0
800000.0
960000.0
610000.0
980000.0
920000.0
1000000.0
1000000.0
250.0
190.0
120.0
150.0
170.0
130.0
190.0
240.0
190.0
190.0
260.0
200.0
REPS
23000.0
3500.0
2500.0
23000.0
17000.0
3700.0
30000.0
8200.0
9100.0
43000.0
31000.0
19000.0
790000.0
1000000.0
820000.0
920000.0
970000.0
780000.0
960000.0
780000.0
980000.0
1000000.0
1100000.0
1000000.0
250.0
170.0
79.0
160.0
220.0
130.0






MEAN
25000.0
4700.0
2100.0
19000.0
18000.0
4500.0
32000.0
11000.0
8100.0
38000.0
28000.0
19000.0
800000.0
900000.0
900000.0
820000.0
920000.0
840000.0
950000.0
720000.0
1000000.0
970000.0
1000000.0
990000.0
250.0
180.0
100.0
160.0
200.0
120.0
190.0
240.0
190.0
190.0
260.0
200.0
STD. DEV.
2849.2
2089.3
366.0
4998.5
4251.7
959.8
1826.6
2523.7
1121.9
5115.1
2373.8
2917.7
27039.5
148256.9
70035.6
89963.1
64103.0
87470.4
16464.8
92059.7
80063.8
57444.9
27967.4
18063.3
2.5
7.9
22.0
11.6
32.8
13.8
2.8
7.8
5.7
3.5
2.1
0.7
SPE Disk Values are not blank-corrected since blanks  were  not  analyzed for two solvents,  and  the  remaining  solvents  had  blank  values  < 1  mg/L.
                                                                                    B-23

-------
                                                                             OIL  & GREASE  DATA
                                                                           FREON REPLACEMENT STUDY
                                                                                   PHASE I
                                                                                                                      June 21, 1993
                                                                                                                        Page 24 of 25
                                                                                                                          Oil  &  Grease  Concentrations:
                                                                                                                            mg/L  in  aqueous  samples  (A)
                                                                                                                            mg/kg in solid/sludge samples
                                                                                                                          (S)
              FACILITY
  37   FORMULATING PLANT
 SCCI

23480





23481
  WASTE STREAM
                                           PRIMARY  EFFLUENT
PRIMARY EFFLUENT
  TECHNIQUE
                     SPE  DISK  47mm  (A)
LIQ/LIQ (A)
  38   LEATHER TANNERY
23481

23481




23481





23482
                                           PRIMARY EFFLUENT

                                           PRIMARY EFFLUENT




                                           PRIMARY EFFLUENT
                     INFRARED (A)

                     SPE  DISK 90mm  (A)
                     SPE  DISK 47mm  (A)
PRIMARY EFFLUENT     LIQ/LIQ (A)
                                 23482

                                 23482
                                 23482
          PRIMARY EFFLUENT

          PRIMARY EFFLUENT
          PRIMARY EFFLUENT
                     INFRARED (A)

                     SPE DISK 90mm  (A)
                     SPE  DISK 47mm  (A)
      SOLVENT
METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

FLON

METHYLENE CHLORIDE
HEXANE
MTBE
PERC

METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

FLON

METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC

METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC
REP1
270.0
220.0
210.0
330.0
210.0
64.0
73.0
66.0
72.0
110.0
71.0
260.0
500.0
430.0
670.0
420.0
1100.0
370.0
640.0
910.0
1000.0
47.0
48.0
100.0
55.0
88.0
49.0
200.0
160.0
83.0
160.0
270.0
150.0
300.0
170.0
200.0
260.0
150.0
REP2
250.0
220.0
210.0
320.0
210.0
82.0
78.0
67.0
70.0
130.0
68.0
280.0
570.0
400.0
710.0
350.0
630.0
540.0
750.0
870.0
750.0
73.0
58.0
150.0
120.0
82.0
76.0
220.0
180.0
64.0
140.0
220.0
160.0
320.0
110.0
160.0
260.0
210.0
REPS





92.0
78.0
48.0
84.0
110.0
52.0










68.0
76.0
130.0
150.0
110.0
54.0











MEAN
260.0
220.0
210.0
330.0
210.0
79.0
76.0
60.0
75.0
120.0
64.0
270.0
540.0
410.0
690.0
390.0
840.0
450.0
690.0
890.0
890.0
63.0
61.0
130.0
110.0
94.0
60.0
210.0
170.0
74.0
150.0
240.0
150.0
310.0
140.0
180.0
260.0
180.0
STD. DEV.
9.9
0.7
3.5
3.5
2.1
14.2
3.1
10.5
7.4
12.8
10.7
19.1
52.3
20.5
30.4
46.7
297.7
123.7
80.6
25.5
188.8
13.5
14.3
21.2
46.1
14.9
14.1
13.4
12.0
13.4
7.8
33.2
11.3
13.4
43.1
27.6
0.7
36.1
SPE Disk Values are not blank-corrected since blanks were not  analyzed for two solvents,  and the  remaining  solvents had  blank  values  <  1  mg/L.
                                                                                    B-24

-------
                                                                             OIL & GREASE DATA
                                                                          FREON REPLACEMENT STUDY
                                                                                  PHASE  I
                                                                                                                      June 21, 1993
                                                                                                                        Page 25 of 25
             FACILITY
 SCC#

23483
  WASTE  STREAM
                                          WASTE SLUDGE
                                                                 TECHNIQUE
                    SONICATION  (S)
                                 23483
          WASTE SLUDGE
                     SOXHLET  (S)
  39    PETROLEUM  REFINERY
23484
API SEPARATOR EFF    LIQ/LIQ (A)
                                 23484

                                 23484
          API SEPARATOR EFF    INFRARED (A)

          API SEPARATOR EFF    SPE DISK 90mm (A)
                                 23484     API  SEPARATOR  EFF    SPE DISK 47mm  (A)
                                 23484     API  SEPARATOR  EFF    SPE COLUMN  II  (A)
                                 23485     INTERCEPTOR EFFLUENT  LIQ/LIQ  (A)
      SOLVENT
DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20

FLON

METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC

METHYLENE CHLORIDE
FREON
HEXANE
MTBE
PERC

FREON
HEXANE
80/20

DUPONT123
FREON
HEXANE
METHYLENE CHLORIDE
PERCHLOR
80/20
                                                                                                                         Oil & Grease Concentrations:
                                                                                                                            mg/L in aqueous samples  (A)
                                                                                                                            mg/kg in solid/sludge  samples  (S)
REP1
190000.0
130000.0
140000.0
220000.0
210000.0
120000.0
170000.0
180000.0
240000.0
180000.0
270000.0
160000.0
20.0
11.0
17.0
5.0 <
34.0
14.0
23.0
16.0
16.0
8.7
18.0
17.0
13.0
17.0
27.0
19.0
9.2
5.0 <
14.0
10.0
22.0
14.0
5.0 <
5.0 <
30.0
5.0 <
REP2
140000.0
140000.0
160000.0
190000.0
170000.0
150000.0
170000.0
220000.0
270000.0
150000.0
240000.0
190000.0
23.0
15.0
18.0
5.0 <
40.0
17.0
24.0
16.0
17.0
14.0
21.0
10.0
12.0
16.0
26.0
20.0
9.2
5.0 <
10.0
12.0
14.0
12.0
9.3
5.0 <
20.0
6.8
REPS
160000.0
120000.0
130000.0
240000.0
220000.0
130000.0
180000.0
190000.0
210000.0
210000.0
220000.0
150000.0
18.0
11.0
17.0
36.0
33.0
18.0














13.0
12.0
8.8
5.0 <
28.0
5.7
MEAN
160000.0
130000.0
150000.0
220000.0
200000.0
130000.0
170000.0
190000.0
240000.0
180000.0
240000.0
170000.0
20.0
12.0
18.0
15.0
36.0
16.0
24.0
16.0
16.0
11.0
20.0
14.0
13.0
16.0
27.0
19.0
9.2
5.0 <
12.0
11.0
16.0
12.0
7.7
5.0 <
26.0
5.8
STD. DEV.
24084.7
9423.1
12447.0
21264.5
25168.8
13055.7
5487.6
22140.3
31176.8
29053.2
28710.4
18624.2
2.7
1.9
0.7
18.0
3 5
1.9
0.7
0.4
0.9
3.9
2.1
4.9
0.3
0.8
0.5
0.6


2.8
1.4
5.1
1.0
2.3

5.4
0.9
SPE Disk Values are not blank-corrected since blanks were  not  analyzed  for  two  solvents,  and  the remaining solvents  had blank values < 1 mg/L.
                                                                                     B-25

-------
                                                                             OIL & GREASE  DATA
                                                                           FREON REPLACEMENT STUDY
                                                                                  PHASE  I
                                                                                                                      June 21, 1993
                                                                                                                        Page 26 of 25
              FACILITY
 SCC#

23485

23485
                                 23485
                                 23485
  UASTE  STREAM
TECHNIQUE
                                                                                        SOLVENT
                                           INTERCEPTOR EFFLUENT  INFRARED (A)
                                       FLON
INTERCEPTOR  EFFLUENT SPE DISK 90mm  (A)  METHYLENE CHLORIDE
                                       FREON
                                       HEXANE
                                       MTBE
                                       PERC

INTERCEPTOR  EFFLUENT SPE DISK 47mm  (A)  METHYLENE CHLORIDE
                                       FREON
                                       HEXANE
                                       MTBE
                                       PERC

INTERCEPTOR  EFFLUENT SPE COLUMN  II  (A)  FREON
                                       HEXANE
                                       80/20
                                                                                                                         Oil & Grease Concentrations:
                                                                                                                            mg/L in aqueous samples  (A)

REP1
15.0
9.0
12.0
16.0
32.0
8.0
6.7
21.0
22.0
21.0
5.0 <
5.0 <
5.0 <
7.0
mq/kq in
REP2
13.0
9.9
18.0
20.0
34.0
8.7
8.0
24.0
24.0
24.0
6.2
5.0 <
5.0 <
8.0
solid/sludqe samples (S)
REPS MEAN
14.0
9.5
15.0
18.0
33.0
8.4
7.4
23.0
23.0
23.0
5.6
5.0 <
5.0 <
7.5

STD. DEV.
1.4
0.6
4.1
3.0
1.6
0.5
0.9
2.5
1.6
2.5
0.8


0.7
SPE Disk Values are not blank-corrected since blanks  were  not analyzed for two solvents, and the remaining solvents had blank values < 1 mg/L.

                                                                                    B-26

-------
                           APPENDIX C
   DISCUSSION OF STATISTICAL TECHNIQUES
USED IN THE PRELIMINARY DATA EVALUATION

-------

-------
          Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
 Data Transformations

        The standard deviations of the measured sample concentrations varied greatly and were
 roughly proportional to the mean sample concentrations, as is common with analytical data.  This
 heteroscedasticity violates the basic ANOVA assumptions, and was taken into account in the statistical
 analysis.

        The association between the standard deviations of sample concentrations and the mean
 sample concentrations was easily demonstrated in this data set by plotting the replicate standard
 deviations versus the mean of the replicate analyses for each sample/solvent combination, as is shown
 in Attachment A.  Linear regressions of the standard deviation of concentration versus the mean
 concentration showed a very significant trend.  Secondary predictors of the standard error including
 solvent, industrial category, sampling point, sample kingdom, and laboratory, were checked by
 including them as predictors along  with the mean concentration.  The only other factor that showed a
 relationship with standard error is laboratory (which is described in greater detail below.)

        In order to allow the use of standard statistical tools, the concentration data were transformed
 so that the data would have constant standard deviations.  If the standard deviations were exactly
 proportional to concentration, i.e.,  if there were no intercept in the regressions, then a logarithmic
 transformation would have produced constant standard deviations [1].  Since there was a positive
 intercept in each of the standard deviation regressions, the data were transformed using  the equation:

                                       z=log(x+c)-log(c),

 where c serves the dual purpose of adjusting for the non-zero intercept of the standard deviation curve
 and allowing for a well-defined transformation that is robust to the negative concentration estimates
 found  in this data.  Examination of the data suggested a value of c= 100 for the aqueous analyses and
 c= 10,000 for both types of solid sample extractions.  These values are on the same order of
 magnitude as the negative of the x-intercept(= -intercept/slope) of each regression, and  they  are of
 sufficient magnitude to keep even the most negative reported concentrations (-56 for aqueous, -1931
 for sonication, -7556 for Soxhlet) a reasonable distance away from the pole at 0 in the log
 transformation.  This distance prevents these points from gaining disproportionate leverage due to
 being transformed far out to the left of the data. Following this transformation, the data no longer
 showed a significant association between standard deviation and mean concentration.  Therefore, the
 transformation was suitable to the ANOVA analysis described below.

        The results on the transformed variable were translated back to statements about concentration
 by inverting the transformation, such that

                                       x=exp(z+log(c))-c
June 1993                                                                                    C-3

-------
Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
Results could then be expressed as approximate proportionate results, in concentration terms, if the
inverse calculations were applied at a representative level of concentration, such as the mean of the
transformed variable. For example, a limit value z, and a mean z0 could be presented as a
proportionate limit in concentration terms by calculating

                                   exp(z, +log(c)) -exp(z0+log(c))
The analyses described in the remainder of this discussion should not be highly sensitive to the
particular values of c used, within the constraints described  above.  A sensitivity check could be done
to demonstrate this by testing alternative values of c.

Negative Concentrations

       While it is counterintuitive to find negative measured concentrations, it can be expected to
occur, at least occasionally, due to analytical variability whenever very  small concentrations are
measured via methods involving blank-subtraction.  It is possible that some sample/solvent
combinations could be removed from this study by setting up statistical  limits on whether the sample
can statistically be shown to contain a non-zero amount of oil and grease,  for instance simply
computing a one-sided hypothesis (at say 5%) that the mean concentration for a  sample/solvent
combination is greater than zero using the three replicate measurements (either with or without the
data transformation).  However, it is desirable that the study remain balanced across solvents, and
since  some solvents show concentrations clearly greater than zero while other solvents do not, such a
rule may not be useful.  Since the data transformation method described above can cope  with negative
measured concentrations, such samples were left in the study for the moment.

ANOVAs

       The ANOVA model deemed best for this analysis was

                                      y=a+bi+gj+du+euk

where i=l...I solvents (l=Freon), j = 1...J samples, and k=l...K (3) replicate analyses. Here a,
bi; gj, and dy are all fixed effects that were estimated6, and eijk is the random measurement error,  with
mean 0 and variance a1.  This model is a standard ANOVA model, and was fitted to  obtain estimates
of each of these parameters and standard errors associated with each estimate.

       Upon testing this model (see Attachment B), it was  clear that the  interaction term is
significant, (i.e., the effect of solvents depends on the sample matrix).
 6With £ b,= 0, £ gj=0, and £ djj= 0 over i for fixed j and over j for fixed i


C-4                                                                                   June 1993

-------
         Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
Evaluation of Solvents

        The evaluation of individual sample-by-sample confidence limits on the difference between
each alternative solvent and Freon would have resulted in too many outcomes to consider and would
not have produced an overall picture of the performance of each alternative solvent.  Instead, an
overall  index of performance that summarizes the similarity of each alternative solvent to Freon,
while taking into  account the differences in the outcomes for each solvent on different samples was
considered desirable.  A natural measure for this is the root mean square deviation across samples
between the alternative solvent and the Freon results.  In terms of the model above, the mean result
for each solvent for a sample is,7
so the root mean square deviation for solvent i is
        This can also be computed as the root mean square deviation between the sample*solvent cell
means for the alternative solvent and Freon.  The smaller this measure, the more closely the results
using the alternative solvent approximate the results using Freon.  RMSD computes the squared
deviation of the average analytical results using alternative solvents on a sample from that of Freon on
the same sample, and accumulates these over all samples to provide an overall measure of agreement.
The data show significant interaction between solvent and sample in the statistical model, that is,
whether alternative solvents extract more or less oil and grease than Freon varies according to the
sample matrix. RMSD measures variations both above and below the Freon results, because we must
capture in our statistic the possibility that an alternative solvent extracts significantly less oil and
grease than Freon on some samples, and more on other samples.  Having the same average results as
Freon across multiple samples is a desirable, but by no means sufficient, test of equivalence of the
solvents.  As a rule of thumb, the RMSD that would be expected by chance alone, for instance if
Freon were tested in this protocol and compared with itself using separate analyses, can be computed.
Under the null hypothesis that there is no actual difference in the procedures, the square of RMSD,
appropriately normalized by the residual error estimate, will have an F distribution.  Therefore,
 7  For typographical simplicity, the carats over each parameter are omitted from this point on even though
   the formulae refer to the sample estimates rather than the theoretical model values.
June 1993                                                                                   C-5

-------
Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
                                      K(RMSD)2
where s is the root mean square error (RMSE) of the model, and I, J, and K are as above.

A 95 % acceptance region for the equality of the test is
                                    RMSD<  —
                                           \  /L
or,  in terms of the normalized RMSD,
                                      RMSD^f^i
Examples of these analyses are shown in Attachment C.

Laboratory Comparisons

       To test the sensitivity of the rankings to the effect of each laboratory, the above rankings were
rerun, dropping out each laboratory in turn. These tests yielded no significant changes in the
comparability of the solvents to Freon.

       Laboratory differences in the analytical standard deviation were also explored. This was done
by an ANOVA of the within-sample*solvent standard deviation of the non-transformed concentration
versus laboratory. One laboratory showed significantly greater RSDs than the other two on soxhlet
and sonication extractions of solid samples.  All labs had statistically similar RSDs on separatory
funnel extraction  of aqueous samples.

Analysis by Type of Sample

       Rankings were also run over subsets of the samples, including divisions by industrial source,
sampling point, kingdom, etc. to look for situations where the ranking changes or where all solvents
are markedly different from Freon. The results of these rankings as divided by industrial source
(petroleum vs. non-petroleum) are discussed in the report of preliminary findings.
C-6                                                                                  June 1993

-------
          Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
        Alternative solvents which rank well overall could be examined for their deviation on
 individual samples in order to spot sample types showing larger deviations, which may indicate areas
 for method improvement.  Since none of the alternative solvents ranked well overall in the
 preliminary analyses, no such examination of individual sample deviation was performed.

 Review Reference

 1.      N.R. Draper and H. Smith, Jr.. Applied Regression Analysis, Second Edition. John Wiley &
        Sons, New York, 1981, pp 238.
June 1993                                                                                  C-7

-------

-------
Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
                                                                            Attachment A

-------
Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
                                    AQUEOUS
                    Std(NET_AMOU)  By  Mean(NET_AMOU)
1400-
1300-
1200-
1100-
1000-
~ 900-
D
O 800-
1 700-
H1 600-
LLJ
S. 500-
•Q
W 400~
300-
200-
100-
o-
- 1 00

•













^^_^--
^ 	
*r~^F
 163540.51                      0.0000

 Parameter  Estimates
 Estimate   Std  Error   t  Ratio  Prob>|t|
 3.9038199   2.19739      1.78   0.0772
 0.1751866   0.01921      9.12   0.0000
 C-10
                                                                             June 1993

-------
        Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
                                      SONICAT
                     Std(NET_AMOU)   By  Mean(NET_AMOU)



o
1

LU
I





700000-
600000-
500000-
400000-

300000-

200000-
100000-
~
o-









-t •^J-^^"""""
ft-\^*J* — *~~^~~^ ' . . . *
AT^VC -. . •.. .











1 1 I 1 I I I 1 I I
-100000 200000400000600000800000
Mean(NET AMOU)
                                         Fitting

                                          	Linear Fit
                                      Linear  Fit
                                   Summary  of Fit
                            Rsquare                0.353493
                            Root Mean Square Error     7629.233
                            Mean of Response         5671.682
                            Observations (or Sum Wgts) 40.93224
                 Source  DF
                 Model       1
                 Error      142
                 C Total    143
                Term
                Intercept
                Mean(NET_AMOU)
 Analysis  of Variance
Sum of Squares  Mean Square
4519150093          5e + 9
8265136937       58205190
 1.28e+10

 Parameter  Estimates
 Estimate   Std  Error  t  Ratio
 1578.4888   1279.76       1.23
 0.1625567   0.01845       8.81
F Ratio
 77.6417
Prot»F
 0.0000
 Prob>|t|
 0.2195
 0.0000
June 1993
                                                  C-ll

-------
Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
                                      SOXHLET
                      Std(NET_AMOU)  By  Mean(NET_AMOU)
                     LLJ
                     2,
                     -o
                     CO
140000-
130000-
120000-
110000
100000
 90000-
 80000-
 70000-
 60000-
 50000
 40000
 30000-
 20000-
 10000-
     0
-10000
              i — i — i
n—i—r
    -100000
                                                  i — i
                                     200000   500000   800000
                                         Mean(NET_AMOU)
                                         Fitting

                                          	Linear Fit
                                       Linear  Fit
                                   Summary  of  Fit
                            Rsquare                0.341522
                            Root Mean Square Error     5148.764
                            Mean of Response         5813.688
                            Observations (or Sum Wgts)  35.17674
                  Source DF
                  Model       1
                  Error      148
                  C Total     149
                Term
                Intercept
                Mean(NET_AMOU)
         Analysis of  Variance
        Sum of Squares   Mean Square
        2034907888          2e + 9
        3923446381       26509773
        5958354269

         Parameter  Estimates
         Estimate  Std  Error   t Ratio
         3095.6208  921.88      3.36
         0.0832695  0.0095      8.76
     F Ratio
      76.7607
     Prob>F
      0.0000
      Prob>|t|
      0.0010
      0.0000
C-12
                                                                            June 1993

-------
Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
                                                                            Attachment B

-------

-------
Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
                                              AQUEOUS

                                        Response:    LNP_AMT
                                            Summary of Fit
                                  R square
                                  Root Mean Square Error
                                  Mean of Response
                                  Observations (or Sum Wgts)
                            0.97779
                            0.126681
                            0.4824
                              587
              Source
              SAMPLE
              SOLVENT
              SAMPLE-SOLVENT
Nparm
33
 5
165
DF
33
 5
165
Effect  Test
 Sum of Squares
  235.42051
   1.16299
  33.66981
F Ratio
444.5370
 14.4939
 12.7155
Prob>F
 0.0000
 0.0000
 0.0000
                                          Whole-Model  Test
                               3.0-
                              -1.0
                                             I   '  ^  I1  '   '  I
                                  -1.0      0.0      1.0      2.0
                                             LNP AMI  Predicted
                                        3.0
                                          Analysis of Variance
                     Source    DF      Sum of Squares        Mean Square       F Ratio
                     Model     203    270.59227            1.33297            83.0609
                     Error       383     6.14641             0.01605           Prob>F
                     C Total     586    276.73868                             0.0000
  June 1993
                                                                                                    C-15

-------
            Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
                                                    SAMPLE
                            t-
                            <
                                 3.0-
                                 2.CM
                                 1.0-
                                 o.o-
                               -1.0-
                                                 ~i    i	1	1	1	1	1	r
                                         0                   1
                                                  SAMPLE   Leverage
Sum of Squares
235.42051

Level
22221
22223
22224
22225
22228
22229
22231
22232
22233
22234
22236
22239
22241
22243
23106
23108
23110
23111
23113
23115
23116
23120
23121
23124
23457
23459
23461
23463
23466
23468
23470
23472
23473
23475
Least
Least Sq Mean
-0.081927652
0.166153922
0.213805049
1.143809535
0.211932028
0.045608445
0.576576027
0.370878501
0.129629655
1.939240086
0.358980370
0.025785114
0.060454805
-0.008480414
0.040835588
-0.052768754
0.026058421
0.114974854
0.082593153
-0.091542461
-0.101100310
0.063497202
0.177725090
0.262299843
1.823537819
0.739219598
1.321908021
1.774738573
0.021799847
0.196272754
1.549298928
0.171667433
1.630797456
1.011166706
                                                  Effect   Test
                                                     F Ratio       OF     Prob>F
                                                     444.5370      33      0.0000


                                                    Squares  Means
                                                          Std Error           Mean
                                                          0.0517172715       -0.08193
                                                          0.0298589806       0.16615
                                                          0.0517172715       0.21381
                                                          0.0298589806       1.14381
                                                          0.0298589806       0.21193
                                                          0.0298589806       0.04561
                                                          0.0298589806       O.57658
                                                          0.0298589806       0.37088
                                                          0.0298589806       0.12963
                                                          0.0298589806       1.93924
                                                          0.0298589806       0.35898
                                                          0.0298589806       0.02579
                                                          0.0298589806       0.06045
                                                          0.0298589806       -0.00848
                                                          0.0298589806       0.04084
                                                          0.0298589806       -0.05277
                                                          0.0298589806       0.02606
                                                          0.0298589806       0.11497
                                                          0.0298589806       0.08259
                                                          0.0298589806       -0.09154
                                                          0.0298589806       -0.10110
                                                          0.0298589806       0.06350
                                                          0.0298589806       0.17773
                                                          0.0298589806       0.26230
                                                          0.0298589806       1.82354
                                                          0.0298589806       0.73922
                                                          0.0298589806       1.32191
                                                          0.0298589806       1.77474
                                                          0.0298589806       0.02180
                                                          0.0298589806       0.19627
                                                          0.0298589806       1.54930
                                                          0.0298589806       0.17167
                                                          0.0310782124       1.62519
                                                          0.0298589806       1.01117
C-16
June 1993

-------
Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
                                                 SOLVENT
3.0-
2.0-
H
^' 1.0-
o.o-
-1.0




• i

• 	 j t ***l~*f II
• "
1 • , , | i , , | , , , | , ,
0.30 0.40 0.50 0.60





SOLVENT Leverage
Effect Test
Sum of Squares F Ratio DF Prot»F
1.1629909 14.4939 5 0.0000
                     Level
                     80/20
                     DUPONT123
                     FREON
                     HEXANE
                     METHYLENE CHLORI
                     PERCHLOR
  Least Squares Means
Least Sq Mean         Std Error         Mean
0.4429666373          0.0132606094      0.460088
0.4689320069          0.0133475652      0.471056
0.4441710175          0.0132606094      0.460378
0.3996973354          0.0132606094      0.417870
0.5210694150          0.0132606094      0.537898
0.5317680406          0.0132606094      0.546996
 June 1993
                                                                                                       C-17

-------
        Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
SAMPLE'SOLVENT






3.0-
2.0-
I —
I
^ 1.0-
o.o-
In —
.0
-1


•'/.•'''.
:<$r-
^
-""/y

\ '• i * i ' i • i ' i * i * i
.0 -0.5 0.0 0.5 1.0 1.5 2.0 2.5
SAMPLE'SOLVENT Leverage
Effect Test







Sum of Squares F Ratio OF Prot»F
33.669811 12.7155 165
Level
22221 ,80/20
Least Squares Means
Least Sq Mean
0.030529205
22221 .DUPONT1 23 -0.052346480
22221, FREON
22221, HEXANE
-0.073108472
-0.446287103
22221 .METHYLENE CHLORI -0.000000000
22221 .PERCHLOR
22223,80/20
0.049646940
0.270663947
22223.DUPONT123 0.183009609
22223.FREON
22223.HEXANE
0.008045125
0542453319
22223.METHYLENE CHLORI 0532777770
22223.PERCHLOR
22224,80/20
0.059973765
0.016463726
22224.DUPONT123 0.258587912
22224.FREON
22224.HEXANE
0.167292518
0.355223892
22224.METHYLENE CHLORI 0.217527813
22224.PERCHLOR
22225.80/20
0.267734435
2.339072219
22225,DUPONT123 2.647357710
22225.FREON
22225.HEXANE
0.549248083
0.288558265
22225.METHYLENE CHLORI 0.432379193
22225.PERCHLOR
22228,80/20
0.606241738
0.255844448
22228.DUPONT123 0.262488136
22228.FREON
22228.HEXANE
0.168376570
0576765722
22228.METHYLENE CHLORI 0.100717481
22228.PERCHLOR
22229.80/20
0.207399809
0.080562062
22229.DUPONT123 0.088903341
22229.FREON
22229.HEXANE
0.007156074
0.028209478
22229.METHYLENE CHLORI 0.039780510
22229.PERCHLOR
22231,80/20
0.029039203
0.407664714
22231, DUPONT1 23 0.710641029
22231. FREON
22231 .HEXANE
0.568079927
0.442544918
22231 .METHYLENE CHLORI 0.686321980
22231 .PERCHLOR
22232.80/20
0.644203593
0.153214764
22232.DUPONT123 0.270130900
22232.FREON
22232.HEXANE
0.408605785
0533756184
22232.METHYLENE CHLORI 0.754308091
0.0000
Std Error
0.1266809262
0.1266809262
0.1266809262
0.1266809262
0.1266809262
0.1266809262
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.1266809262
0.1 266809262
0.1266809262
0.1266809262
0.1266809262
0.1266809262
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
00731392668
C-18
June 1993

-------
Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
22232.PERCHLOR
22233.80/20
22233.DUPONT123
22233.FREON
22233.HEXANE
22233.METHYLENE CHLORI
22233.PERCHLOR
22234,80/20
22234.DUPONT123
22234.FREON
22234.HEXANE
22234.METHYLENE CHLORI
22234.PERCHLOR
22236,80/20
22236,DUPONT123
22236.FREON
22236.HEXANE
22236.METHYLENE CHLORI
22236.PERCHLOR
22239.80/20
22239.DUPONT123
22239.FREON
22239.HEXANE
22239.METHYLENE CHLORI
22239.PERCHLOR
22241 .60/20
22241 .DUPONT1 23
22241.FREON
22241 .HEXANE
22241 .METHYLENE CHLORI
22241 .PERCHLOR
22243.80/20
22243.DUPONT123
22243.FREON
22243.HEXANE
22243.METHYLENE CHLORI
22243.PERCHLOR
23106.80/20
23106.DUPONT123
23106.FREON
23106.HEXANE
23106.METHYLENE CHLORI
23106.PERCHLOR
23108,80/20
23108.DUPONT123
23108.FREON
23108.HEXANE
23108.METHYLENE CHLORI
23108.PERCHLOR
23110.80/20
23110.DUPONT123
23110.FREON
23110.HEXANE
23110.METHYLENE CHLORI
23110.PERCHLOR
23111,80/20
23111.DUPONT123
231 11, FREON
231 11. HEXANE
231 11. METHYLENE CHLORI
231 11, PERCHLOR
23113.80/20
23113.DUPONT123
23113.FREON
23113.HEXANE
23113.METHYLENE CHLORI
23113.PERCHLOR
23115.80/20
2311S.DUPONT123
23115.FREON
23115.HEXANE
23115.METHYLENE CHLORI
23115.PERCHLOR
231 16.80/20
23116.DUPONT123
23116.FREON
23116.HEXANE
23116.METHYLENE CHLORI
23116.PERCHLOR
23120,80/20
23120.DUPONT123
23120.FREON
23120.HEXANE
23120.METHYLENE CHLORI
23120.PERCHLOR
23121.80/20
23121.DUPONT123
23121.FREON
231 21 .HEXANE
231 21 .METHYLENE CHLORI
23121 .PERCHLOR
23124.80/20
0.405255284
0.188988959
0.365724967
-0.201028849
0.196219393
0.076333861
0.151539602
1.915012680
2.050117391
1 .842390883
1.787820143
2.083455076
1 .956644340
0.091455233
-0.079757881
0.315852264
0.008113392
1.610903084
0.207316127
0.021363971
0.006132858
0.035865335
-0.027923760
0.023174515
0.096097765
0.063867979
0.043815594
0.051997954
0.085105647
0.034613868
0.083327785
0.074858149
-0.397055696
0.041624164
-0.065607314
0.056849687
0.238448526
-0.037921896
0.009991076
0.090729899
0.013890435
-0.001218016
0.189542026
-0.304263947
0.012451833
0.107839250
0.010516094
-0.248037118
0.104881365
0.054514033
-0.112464383
-0.057731793
0.051891377
0.115524202
0.104617092
0.032430537
0.113213271
0.010865913
0.246631887
0.134357581
0.152349936
-0.012864876
-0.112727899
0.156503533
0.152200758
0.158711876
0.153735529
-0.353191414
-0.215X8359
0.105828916
-0.000000000
0.107651494
-0.194235402
-0.031491895
-0.755272277
0.014470841
0.033139273
-0.002536661
0.135088860
0.035937835
0.070701751
0.039128838
0.045570111
0.107241338
0.082403339
0.106309145
0.142302937
0.128118963
0.177416900
0.298465221
0.213737374
0.406740348
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
June 1993
C-19

-------
        Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
23124.DUPONT123
23124.FREON
23124.HEXANE
23124.METHYLENE CHLORI
23124.PEHCHLOR
23457,80/20
23457.DUPONT123
23457.FREON
23457.HEXANE
23457 .METHYLENE CHLORI
23457.PERCHLOR
23459,80/20
23459,DUPONT123
23459.FREON
23459.HEXANE
23459.METHYLENE CHLORI
23459.PERCHLOR
23461 ,80/20
23461 .DUPONT1 23
23461. FREON
23461.HEXANE
23461 .METHYLENE CHLORI
23461. PERCHLOR
23463,80/20
23463.DUPONT123
23463.FREON
23463.HEXANE
23463.METHYLENE CHLORI
23463.PERCHLOR
23466,80/20
23466.DUPONT123
23466.FREON
23466.HEXANE
23466.METHYLENE CHLORI
23466.PERCHLOR
23468,80/20
23468.DUPONT123
23468.FREON
23468.HEXANE
23468.METHYLENE CHLORI
23468.PERCHLOR
23470,80/20
23470.DUPONT123
23470.FREON
23470.HEXANE
23470.METHYLENE CHLORI
23470.PERCHLOR
23472,80/20
23472.DUPONT123
23472.FREON
23472.HEXANE
23472.METHYLENE CHLORI
23472.PERCHLOR
23473,80/20
23473.DUPONT123
23473.FREON
23473.HEXANE
23473.METHYLENE CHLORI
23473.PERCHLOR
23475,80/20
23475.DUPONT123
23475.FREON
23475.HEXANE
23475.METHYLENE CHLORI
23475.PERCHLOR
0.142777666
0.122163816
0.133983982
0.337924452
0.430208791
1.548051893
1 .467895079
2.037291907
1.950458735
1.643079228
2.294450072
0.893192151
0.360133237
0.948661900
0.657482979
0.420806466
1.155040855
1 .065287664
1 .569397541
1.158550214
1 .019989934
1.522559692
1.595663081
1.679632893
1.961525653
1 .978669660
1 .610839908
1.651522296
1.766241026
-0.020279108
0.032455987
0.035542717
0.014449181
0.029515790
0.039114518
0.128916135
0.218894130
0.245849721
0.198197495
0.202826321
0.182952721
.499087286
.546585294
.507133089
.603586213
.541638107
1.597763579
0.065431592
0592055667
0.126754795
0.042734632
0593780572
0.209247342
.497531799
.726140760
.609112920
.464292065
.650423816
.837283378
0.898253438
1.115189881
0.845932136
0.757485270
1.402980525
1.047158987
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
00731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0895769419
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
0.0731392668
C-20
June 1993

-------
Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
                                                                            Attachment C

-------

-------
 Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
AQUEOUS
SAMPLE
































RMSD
RMSE
J
1
K
22223
22225
22228
22229
22231
22232
22233
22234
22236
22239
22241
22243
23106
23108
23110
23111
23113
23115
23116
23120
23121
23124
23457
23459
23461
23463
23466
23468
23470
23472
23473
23475





95% AL
FREON
0.008
0.549
0.168
0.007
0.568
0.409
-0.201
1.842
0.316
0.036
0.052
0.042
0.091
0.108
-0.058
0.011
0.157
0.106
0.014
0.039
0.128
0.122
2.037
0.949
1.159
1.979
0.036
0.246
1.507
0.127
1.609
0.846

0.127
31
6
3
0.126
Sample * Solvent
Means


80/20 DUPONT123 HEXANE METHYLEN PERCHLOR
0.271
2.339
0.256
0.081
0.408
0.153
0.189
1.915
0.091
0.021
0.064
0.075
-0.038
-0.304
0.055
0.032
-0.013
-0.353
-0.031
0.036
0.106
0.407
1.548
0.893
1.065
1.680
-0.020
0.129
1.499
0.065
1.498
0.898
0.374





0.183
2.647
0.262
0.089
0.711
0.270
0.366
2.050
-0.080
0.006
0.044
-0.397
0.010
0.012
-0.112
0.113
-0.113
-0.215
-0.755
0.071
0.142
0.143
1.468
0.360
1.569
1.962
0.032
0.219
1.547
0.292
1.726
1.115
0.466





0.242
0.289
0.277
0.028
0.443
0.234
0.196
1.788
0.008
-0.028
0.085
-0.066
0.014
0.011
0.052
0.247
0.152
0.000
0.033
0.046
0.177
0.134
1.950
0.657
1.020
1.611
0.014
0.198
1.604
0.043
1.464
0.757
0.163





0.233
0.432
0.101
0.040
0.686
0.754
0.076
2.083
1.611
0.023
0.035
0.057
-0.001
-0.248
0.116
0.134
0.159
0.108
-0.003
0.107
0.298
0.338
1.643
0.421
1.523
1.652
0.030
0.203
1.542
0.294
1.650
1.403
0.321





0.060
0.606
0.207
0.029
0.644
0.405
0.152
1.957
0.207
0.096
0.083
0.238
0.170
0.105
0.105
0.152
0.154
-0.194
0.135
0.082
0.214
0.430
2.294
1.155
1.596
1.766
0.039
0.183
1.598
0.209
1.837
1.047
0.170





June 1993
C-23

-------

-------

-------
U.S. Environmental Protection Agency
Region 5, Library (PL-12J)
77 West Jackson Boulevard, 12th Floor
Chicago,  IL  60604-3590

-------
         Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease
                                              .
ERRATA SHEET
                                           /»

The following text supersedes that of Section 5.6 found on pages 22-23.

       Exhibit 16 summarizes all of the solvent-Freon ratios on one graph. In this graph, the mean
solvent-Freon ratio (computed prior to log-transformation of the data) is plotted on a logarithmic scale
so that amounts of oil and grease greater or less than the amount extracted by Freon 113 are
equidistant from 1.00.
       This graph  shows that the mean solvent-Freon ratios range from approximately 0.4 to 3.3,
depending on the solvent, technique, and type of sample being extracted.  Of interest in this graph is
the influence of the solvent or technique on the average amount of material extracted.  For example,
Soxhlet extraction with the alternative solvents seems to extract somewhat more oil and grease than
the reference Soxhlet extraction with Freon 113, whereas less oil and grease is  extracted with
sonication rather than with Soxhlet using Freon 113 unless methylene chloride is used in the
sonication extraction.  It must be remembered that these ratios represent the average amount of
material  extracted,  whereas the RMSD represents the deviation from the amount extracted by Freon
 113 on an individual sample basis.  Therefore, although these averages are interesting, they cannot be
relied upon as the final criterion for equivalence.
        The use of Freon 113 as  the extracting solvent in the alternative techniques allowed the
variables of solvent and technique to be separated.  Using cartridges (columns), the amount of oil and
grease extracted by Freon 113 and the alternative solvents is less than the amount  extracted using the
reference separatory funnel method for  all solvent-technique combinations except 80/20 with the new
cartridges.  However, all solvents extract more material than Freon 113 when extracted by the same
 cartridge technique.
        Using 47 mm disks with Freon 113, nearly twice as much oil  and grease is extracted than is
 extracted by Freon 113 in the reference separatory funnel method. The amounts of oil and grease
 extracted by the alternative solvents using the 47 mm disk are even greater than the amount extracted
 by Freon 113. For 90 mm disks, the amount of oil and grease extracted  by Freon 113 is slightly less
 than  the amount extracted using the reference separatory funnel method,  but the alternative solvents
 extract more than Freon 113 by either the reference separatory funnel extraction or 90 mm disk
 extraction.
        The effects of solvent versus technique cannot be separated for Flon-316 and NDIR because
 Freon 113 was not tested with the NDIR  technique.  Therefore, it is not  known whether the larger
 amount  of oil and  grease indicated by the Flon/NDIR technique results from the use of Flon-316 or
 results from the way in which the NDIR  is calibrated.
         It must be emphasized that the solvent to Freon ratios are averaged, and that the differences
 may not be statistically significant due to the high variability of the data.   Although significance tests
 could be performed, the RMSD  is a more reliable indicator of the difference between alternative
 solvents/techniques and the reference Freon 113 separatory funnel method.
 June 1993                                                                             Errata-1

-------
 Preliminary Report of EPA Efforts to Replace Freon for the Determination of Oil and Grease





 ERRATA SHEET




 This exhibit replaces Exhibit 16 shown on page 37 of the original report.



                       Mean Solvent-Freon Ratios for All Techniques Tested
       MTBE
         Flon
        Freon
+,    DuPont

 o
 


*o
CO

        80/20
     Perchlor
       MeCl,
      Hexane       o
             0.4
                                         Ideal


                                         Ratio

                                           i
O   D  A     *
    ED
                                     a
                                    aa
      a
                                                  • A
                                                          A •    o
               1


         Solvent to Freon Ratio
A    Aqueous



•    Soxhlet



O    Sonication



a    SPE Column (old)



A    SPE Column (new)



o    SPE Disk 47 mm



*    SPE Disk 90 mm



•    Infrared
                                                                     
-------