BACT/LEAR Clearinghouse

   A Compilation Of Control
   Technology Determinations

   Volume IIA
   Appendix G
   Source Type Codes 1.0-5.0
                    STATE
             EPA
                            LOCAL
00
0)
CO
   Developed As Part Of A Joint Effort
   Between The U.S. Environmental Protection Agency
   And State And Local Air Pollution Control Agencies

-------

-------
BACT/LAER Clearinghouse
                  Prepared By

        Emission Standards And Engineering Division
         US. Environmental Protection Agency
         Region V, Library
         230 South Dearborn Street
         Chicago, Illinois  60604
        U. S.  Environmental Protection Agency
    Office of  Air Quality Planning and Standards
    Research Triangle Park, North Carolina  27711
                  May 1984

-------
                                  DISCLAIMER
     This report was prepared by PEDCo Environmental, Inc., Cincinnati  Ohio
under Contract No  68-02-3512, Work Assignment No. 60.  It has been renewed'
by the Emission Standards and Engineering Division of the Office of Air Quality
Planning and Standards, U.S. Environmental Protection Agency and approved for
publication   Approval  does not signify that the contents necessarily reflect
the views and policies  of the U.S.  Environmental Protection Agency.  Mention
of trade names or commercial products is not intended to constitute endorse-
ment or recommendation  for use.   Copies of this report are available from the
National  Technical  Information Service, 5285 Port Royal  Road,  Springfield,
                                     11

-------
                                  CONTENTS
Volume
Figures	      iv
Acknowledgment  	       v

     Introduction 	       1
          Background  	       1
          Report format 	       2
          Improvements to the system	      12

     Procedures for Future Submissions to the Clearinghouse 	      16

Appendices

     A.  Table 1.  Index of control technology determinations ....     A-l
     B.  Table 2.  Control technology determinations by type
           of source - summary of emission limitations	     B-l
     C.  Table 2A.  Control technology determinations for
           external combustion sources	     C-l
     D.  Detailed listing of source type codes	     D-l
     E.  Abbreviations for process and emission limits	     E-l
     F.  Format for BACT/LAER clearinghouse submittals and
           instructions for completing BACT/LAER clearing-
           house input summary sheet	     F-l

Volume IIA

     G.  Detailed source listings
         Source type code 1.0	     G-l
         Source type code 2.0	   G-152
         Source type code 3.0	   G-175
         Source type code 4.0	   G-255
         Source type code 5.0	   G-318

Volume I1B

     G.  (continued)  Detail^ soy r^e^i-st Jims
         Source type code 6.0	".''V'l;'v'vn . ,	   G-577
         Source type code 7.0	   G-723
         Source type code 8.0	   G-784
         Source type code 9.0	   G-879
         Source type code 10.0	G-1031
         Source type code 11.0	G-1134
         Source type code 12.0	G-1178


                                      iii

-------
                                             APPENDIX  —  DETAILED  SOURCE LISTING
                                                                                                                         05/23/1984




SOURCE TYPE/SIZE—         EXTERNAL COMBUSTION -  COAL                                      1780.00 MVI
                           „____.„ __ __• __ __• _ _ _..._ — -».___ — — .. __ — — »,_ — — — -. — — — — _ — — —. ™ — — ™ — — — — —— — — — •-» — •- — — — — ••• — _... — .._ — — — •—— — — — — — — •« — — — — — — — ^ ..•. — — — —


COMPANY NAME/SITE LOCATION  AL ELEC COOP INC                                             ANDALUSIA, AL 36420
                            P. 0. BOC 550                                                                           CHOCTAW COUNTY
                           »__« ___.».. ..____ .__•»_ ._«««_» »^_.w« — »._....——•* __~_ —— — — — — —>_~__« _•—_ —— ™—— — — ..———— — •._— — — — — — — — —— — — ~ — — — — — ._«.. _ •.— —«.


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE— 02/24/81
PERMIT NO. AL 071                                                                              ESTIMATED DATE OF START-UP—   1986
DETERMINATION MADE BY       ALABAMA APCD                   SUE ROBERTSON                       (205J-834-6570
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)

= = = = = = = = = = = = = = = = = r = = = = = = = rr = = = = = = = = = = = = = = = === = r = = = === = = = = = = = = = === = = r = = = = r= = =:= = =====r===== = r ==rr===r ==rr===r= === ====rr= ===r== ===rr=


PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ...  &  BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ...  PCT  EFF
LIGNITE BOILER
                                   4805.00 MMBTU/H EA
                                                           PM      144.0000 LB/H
                                                                   631.0000 T/YR
                                                                            ESP
                                                           S02    3803.0000 LB/H
                                                                 16653.0000 T/YR
                                                                            FGD
                                                           NOX    2883.0000 LB/H
                                                                 12628.0000 T/YR
                                                                            BOILER DESIGN * OPERATION
                                                           CO      470.0000 LB/H
                                                                  2060.0000 T/YR
                                                                            BOILER DESIGN i OPERATION
                                                                                                     NSPS

                                                                                                     99.80
                                                                                                     NSPS

                                                                                                     90.00
                                                                                                     NSPS
                                                                                                      BACT
NOTES 	
ESTIMATED STARTUP DATES
— UNIT 1, 3/86 - UNIT 2,  5/91  -  UNIT 3,  7/96 - UNIT 4, 9/01.
 (*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

 PAGE G-   1
                                                                                                       INITIAL REVIEW  POST STARTUP
                                                                                          REVIEW STATUS;   04/01/1933
                              ID NUMBER AL-0001
                                                                                    SOUKCE  TYPE  CCDE
                                                                                                        1.1

-------
                                                       -- DETAILED SOURCE  LISTING
                             EXTE-NAL CCVI:'JSTICM - COAL                                         i^.ec r.j


COMPANY  N'-ME-'SITE  LOCATION  AMERICAN LIGNITE PRODUCTS                                          IONE , CA


DETERMINATION  IS BACT FOR A NEW SOURCE.                                                         DATE OF PERMIT ISSUANCE—   01/10/S4
PE^IIT NO.  SJ  83-02                                                                              ESTIMATED TATE CT STAHT-UP--
DETCR.MI'.'VTIC-)  M/DE BY       EFA REGION IX                  JOE SLAMOVICH                        (<-l5)-<)~^-f.2?S
                              (iGENCY)                   (AGEK'CY CONTACT PERSON)                     (PHONE)



PPOCESSES SL?JECT                      THi?OU?'^UT        POLLUTANT    EMISSION LIMITS                                     ...& BASIS
TC THIS  PERMIT                          CAPACITY          EMITTED            CONTROL EQUIPMENT  CR  PROCESS MODIFICATION   ... PCT  EFF


CC:-'.I;'J37C°,  FLUIDIZED  BED              23.30 7/H
                                                            N02      61.5000 LB/H
                                                                             CIKCULATIK'3 FLUIFIZED  BED
                                                            CO       3"+. 2000 LB.-H
                                                                             CIRCULATING FLUIDIZED  BED
                                                            S02      65.COOC LB-'H
                                                                             LIMESTONE INJECTION                               94.30
                                                            PM        7.5COO LB/H
                                                                             BAGHOUSE                                          99.90


NOTES -----------












                                                                                                        INITIAL REVIEW  POST STARTUP
(*> INDICATES DATUM W?S TPUNCATCD  FC1?  THIS TADLE.                                         REVIE!! STATUS:

PAGE G-   2                                            ID N'Jt'BER  CA-OOsSA                                    SOV^CE  TYPE CCDE    1.1

-------
                                            APPENDIX ~ DETAILED SOURCE LISTING
                                                                                                                        05/22/1934



SOURCE TYPE/SIZE—         EXTERNAL COMBUSTION - COAL                                        17.00 MW


COMPANY NAME/SITE LOCATION  AMERICAN LIGNITE PROD. CO.                                        IONE, CA


DETERMINATION IS                                                                              DATE OF PERMIT  ISSUANCE—  12/21/83
PERMIT NO.                                                                                    ESTIMATED DATE  OF  START-UP—    1985
DETERMINATION MADE BY       AMADOR COUNTY APCD             EARL WITHYCOMBE                     (916)-862-1233
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     ( FHONE)



PROCESSES SUBJECT                    THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... & BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
FLUID BED COMBUSTION
                                   240.00 MM3TU/H
                                                          PM        0.0156 GR/DSCF
                                                                           BAGHOUSE
                                                          S02     115.0000 PFM
                                                                           LIMESTONE BED
                                                                           1.5X S FUEL
                                                          NOX     150.0000 PFM
                                                                           FLUID BED
                                                                           STAGED COMBUSTION
                                                          CO      138.0000 PPM
                                                                           STAGED COMBUSTION
                                    BACT
                                    99.93
                                    BACT
                                    94.25

                                    BACT
                                    BACT
NOTES 	
RECIRCULATING FLUID BED INCREASES S02/LIMESTONE INTERACTION AND CAPTURE, MAINTENANCE OF BED TEMPERATURE AT  1560  F  KEEPS NOX PR
CDUCTION LOW, BAGHOUSE FOLLOWS RECIRCULATIK'G CYCLONE ANO MULTICLONE FOR PARTICULATE CONTROL.
(*) INDICATES DATUM WAS TRUNCATED  FOR THIS TABLE.

PAGE G-   3
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS;
                                                     ID NUMBER CA-004S
                                                                                                           SOURCE  TYPE  CODE
                                                                                                                               1.1

-------
                                             APPENDIX  —  DETAILED  SOURCE LISTING
                                                                                                                         C5/22/19S<+



SOURCE TYPE/SIZE—-         EXTERNAL COMBUSTION -  COAL                                       350.00 MM


COMPANY NAME/SITE LOCATION  ARIZONA PUBLIC SERVICE CO., CHOLLA UNIT*                   JOSEPH CITY, AZ
                           — — — — — — — — — — — — — -- — — — — — — — — — — — — — — — — — — —. — — — *. — — — — — —™ —— —^ —— ___—— — _ ——— — —__ — ™ —__ — _____—__«. — ____.________-.__ — _______

DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—  02/15/78
PERMIT KO. AZP 78-01                                                                           ESTIMATED DATE OF START-UP--
DETERMINATION MADE BY       EPA REGION IX                 JIM HANSON                           (415 )-97<+-8038
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT       POLLUTANT    EMISSION LIMITS                                   ... & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... FCT EFF
•" — — — — — — — — — — — — — — — •— — — — — — — — — — — — — — — — — — — — — — — _ — — — — __ — — »__— — «.___-._____ — __ — __«.____„.____________ __,_ _ — ___»»„_»_____ _________ _ _______,, — __ —_..__

COAL FIRED BOILER                   350.00 MW
                                                          PM        0.0500 LB/MM3TU
                                                                            ESP
                                                          S02       0.0720 LB/MM3TU
                                                                            U'ET  LIMESTONE SCRUBBING                          94.00
                                                                            LOW  S COAL
                                                          NOX       0.7000 LB/MN3TU                                         NSPS
COAL HANDLING AREAS
                                                          PM
                                                                            DUST CONTROL SYS
LIMESTONE HANDLING AREAS
                                                          PM
                                                                            DUST CONTROL SYS


NOTES 	
THE DEGREE OF CONTROL WAS PROPOSED BY CO. IN ITS APPLICATION. FUGITIVE D UST SHALL BE CONTROLLED DURING CONSTRUCTION BY WATER
SPRAY. BOTTOM ASH SHALL BE PUMPED TO A SPRAY POND.  ASH SHALL BE MIXED  WITH WASTE SLUDGE FROM S02 ABSORBERS AK'D OR
HASTEWATER FROM COOLING TOWER AND TRANSPROTED IN A SLURRY TO A SEPERATE DISPOSIAL AREA





                                                                                                      INITIAL REVIEW  POST STARTUP
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEW STATUS:   04/01/1933

PAGE G-   <+                                           ID NUMBER AZ-0003                                    SOl'"CE TYPE CODE    1.1

-------
                                             APPENDIX ~  DETAILED SOURCE LISTING
                                                                                                                         05/22/1984



SOURCE TYPE/SIZE—         EXTERNAL COMBUSTION - COAL                                       800.00 KM


COMPANY NAME/SITE LOCATION  ARKANSAS PUR & LT CO.                                           NEWARK, AR
                                                                                                                INDEPENDENCE COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                         DATE OF  PERMIT ISSUANCE—  03/30/78
PERMIT NO. PSD-AR-48                                                                           ESTIMATED  DATE OF START-UP-
DETERMINATION MADE BY       EPA REGION VI                  JOHN BUNYAK                         (214 )-767-1594
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... t BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS  MODIFICATION  ... PCT EFF
~^ — — — — — — -. — — — — — — — — — — — »• _____«.«_ _ -. •> _____ __ _____,. — .,fc.._»,-,»_____ — — _ _ — „. ,.»^._ «„... _.._ __ «. — __ -,__ ««. « _ _.. _ v __ _ «. ^ _ ____•.«._ __. «.^^___ _^_______^»_ «. ._

COAL-FIRED STEAM GEN                800.00 MM
                                                           S02        0.9300 LB/MMBTU                                          NSPS
                                                                            LOW S WESTERN COAL
                                                           PM         0.1000 LB/MI-IBTU
                                                                            ESP                                               99.50


NOTES 	















                                                                                                      TMTTTftL crviEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FCR THIS TABLE.                                        REVIEW STATUS:   0^/01/1983

PAGES-   5                                           ic  ;•'„:•;.> :.- . .  .                                     .   	,-_ ^^i    1.1

-------
                                            APPENDIX -- DETAILED SOURCE LISTING
                                                                                                                        05/23/1934



SOURCE TYPE/SIZE—         EXTERNAL COMBUSTION - COAL                                       730.00 HW


COMPANf NAME/SITE LOCATION  ASSOC.  ELECT.  COOP., INC.                                              , MO
                            THOMAS  HILL  STATION                                                                     RANDOLPH CCUNTY


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF  PERMIT  ISSUANCE--  02/06/78
PERMIT NO.                                                                                    ESTIMATED DATE  OF  START-UP--   1982
DETERMINATION MADE BY       EPA REGION VII                DANIEL RODRIGUEZ                    (816)-374-65£5
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                    THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ...  & BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ...  FCT EFF


BOILER, COAL FIRED (UNIT 3), PU*   6588.00 MMBTU/H
                                                          S02       1.2000 LB/MMBTU                                          BACT
                                                                           WET LIMESTONE SCRUBBER                            90.00
                                                          PM        0.1000 LB/MM3TU                                          BACT
                                                                           COLD-SIDE ESP                                     99.70
                                                          NOX       0.7000 LB/rr.3TU                                          NSPS
                                                                           BOILER DESIGN


NOTES 	
PLANT NAME- THOMAS HILL (EXISTING UNIT 1 - 180MVJ, NET, EXISTING UNIT Z - 303 KV4, NET). THE NEW UNIT 3 IS SUBJECT  TO NSFS, SUSP
ART D. EXISTING UNITS 1 AND 2 WILL  BE LIMITED TO 8.0 LB S02/MMBTU (3-HR. AVG. ) BECAUSE OF POSSIBLE
AMBIENT STANDARD VIOLATIONS. THE EXISTING  UNITS WILL BURN WASHED COAL (4.5X S BY WT.). UNIT 3 WILL BURN UNWASHED  COAL  (5.57. S
BY WT.). MISSOURI COAL
(*) INDICATES DATUM WAS TRUNCATED  FOR THIS TABLE.

PAGE G-   6
                                                                                                     INITIAL REVIEW  POST STARTUP
                                                                                        REVIEW STATUS;  04/01/1953
ID NUMBER MO-0002
                                                     SOURCE TYPE CODE
                                                                         1.1

-------
                                            APPENDIX -- DETAILED SOURCE LISTING
                                                                                                                        05/22/193
-------
                                             APPENDIX — DETAILED  SOURCE LISTING
                                                                                                                          05/22/1984



SOURCE TYPE/SIZE	         EXTERNAL COMBUSTION - COAL                                       1500.00 KW
                           — — — — — — — — — — — — — — — — — — — -.-.«- — —..— ——. — •,. — — — —._ — — — — — _ — _-.___..__________ — _________,._______.__,..____________„._ ___________

COMPANY NAME/SITE LOCATION  BASIN ELECTRIC POWER COOP.                                    WHEATLANO, WY
                           — —— — — — — — — — — ——— — —_ — — — — ..__—___,.,».. — _ ___ »_____ _ _ _ _________ __________„.__»__» _ _ -• • _ — —__...•___-...___.,_« ______ -»___«.

DETERMINATION IS BACT FOR A NEW SOURCE.                                                         DATE OF PERMIT  ISSUANCE—  05/14/76
PERMIT NO. CT-36                                                                                ESTIMATED DATE  OF  START-UP--
DETERMINATION MADE BY       WYOMING AQD                    ECKART  HAAS                          (307)-777-7391
                             (AGENCY)                   (AGENCY CONTACT  PERSON)                    (FHCNE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ...  4 BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT OR PROCESS MODIFICAT^4  ...  PCT EFF
*•"•- — — — — — — _ — — — __—.__._ — ___.-.-____ — __—.«.___«,___....___ ..__ — — •.».__».«.,—__•___* — ,•___„•____— ____ — — _.»_._ __ __,„___.•..____ _____ __„ ___»•___ ____., _____H_>«__^

BOILER, COAL, 2 EA                 5513.62 MM3TU/H
                                                           S02       0.2000 LB/t-fttBTU                                          NSPS
                                                                             FGQ, WET LIMESTONE SCRUBBER                       90.00
                                                           PM        0.1000 LB/MH3TU                                          NSPS
                                                                             ESP                                               99.50
BOILER, COAL                       5513.62 MMBTU/H
                                                           S02       0.2000 LB/MMBTU                                          NSPS
                                                                             FGD, DRY LIME SCRUBBER                            90.00
                                                           PM        0.1000 LB/MKBTU                                          NSPS
                                                                             ESP „                                             99.50


NOTES 	
UNIT 1 START UP WAS 07/01/80. UNIT 2 START UP WAS 07/01/81. UNIT 3, THE  FIRST FULL-SCALE DRY SCRUBBER INSTALLED CM A  LARGE  STE
Aft GENERATOR IN THE U.S., IS PRESENTLY UNDERGOING S'u'BS~ANTIAL MOD. TO MEET  S02 EMISSION LIMITS.









                                                                                                       INITIAL REVIEW  POST  STARTUP
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEW STATUS:

PAGE G-   8                                           ID HUI1BER WY-0013                                     SOURCE TYPE  CODE    1.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE—
                            EXTERNAL COMBUSTION - COAL
                                                                                            880.00 MM
COMPANY NAME/SITE LOCATION  BIG RIVERS ELECT. -D.B. WILSON STATION
                            D.B.  WILSON STATION
                                                                                        LIVERMORE, KY 42352
                                                                                                                       OHIO COUNTY
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT NO. C-80-41
DETERMINATION MADE BY       KENTUCKY  DAPC
                             (AGENCY)
                                                          BILL DILLS
                                                       (AGENCY CONTACT PERSON)
                                                                                              DATE OF  PERMIT ISSUANCE—  03/11/81
                                                                                              ESTIMATED  DATE OF  START-UP—   1964
                                                                                              < 502 )-564-33S2
                                                                                                   (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
                                                       POLLUTANT
                                                        EMITTED
                                                                    EMISSION  LIMITS
                                                                           CONTROL EQUIPMENT OR  PROCESS MODIFICATION
                                                                                                                           8 BASIS
                                                                                                                           PCT EFF
BOILER, COAL FIRED
                                   4585.00 MMBTU/H EA
COAL HANDLING
LIMESTONE HANDLING
NOTES ------ .....
2 C04L FIRED 440 MM BOILERS
                                   3281.00 MT/YR


                                 279000.00 T/YR
                                                          PM

                                                          S02

                                                          NOX


                                                          PM


                                                          PM
                                                                    0.0300  LB/MMBTU
                                                                            ESP
                                                                    1.2000  LB/MMBTU
                                                                            WET SCRUBBER
                                                                    0.6000  LB/M!13TU
                                                                            BOILER DESIGN  &  OPERATION
                                                                           LIMITED OPERATING COrrDITIONS
                                                                           LIMITED OPERATING CONDITIONS
                                                                                                                             BACT
                                                                                                                             99. SO
                                                                                                                             BACT
                                                                                                                             90.00
                                                                                                                             BACT
(*) INDICATES DATUM WAS TRUNCATED FOR THIS  TABLE.

PAGE G-   9
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW  STATUS:   04/01/1933
                                                      ID KLI'.r.ER Ki-0009
                                                                                                           SOURCE TYPE CODE    1.1

-------
                                             APPENDIX  —  DETAILED  SOURCE  LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE---         EXTERNAL COMBUSTION -  COAL                                       2<+6.00  MW


COMPANY NAME/SITE LOCATION  BOARD OF PUBLIC UTILITIES                                   KANSAS CITY,  KS
                                                                                                                  WYAMDOTTE COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                         DATE  OF PERMIT ISSUANCE—  09/29/76
PERMIT NO.                                                                                     ESTIMATED  DATE OF START-UP--   1931
DETERMINATION MADE BY       EPA REGION VII                CHARLES WHITMORE                     (8161-374-6525
                             (AGENCY)                  (AGENCY CONTACT PERSON)                    (PKONE )



PROCESSES SUBJECT                     THROUGHPUT       POLLUTANT     EMISSION  LIMITS                                    ... & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            COts'TROL EQUIPMENT OR  PROCESS  MODIFICATION  . . . PCT EFF


BOILER, COAL FIRED, PULV.           346.00 MW
                                                          S02        1.2000 LB/MflBTU                                          BACT
                                                                           LOW  S  WESTERN  COAL
                                                          PM         0.1000 LB/Mr;BTU                                          NSPS
                                                                           ESP
                                                          NOX        0.7000 LB/MMBTU                                          NSPS
                                                                           BOILER DESIGN


NOTES 	
PLANT NAME: NEARMAN CREEK. THE UNIT IS SUBJECT  TO  NSPS, SUSPART D.












                                                                                                      INITIAL REVIEW  POST STARTUP
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:   Gn/01/1933

PAGE G-  10                                           ID  NUMBER KS-0012                                     SOURCE  TYPE CCDE    1.1

-------
                                            APPEKDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984




SOURCE TYPE/SIZE—         EXTERNAL COMBUSTION - COAL
                           — ..___ — —,-,____ — __•___.___„__•_.,__ — _____.»____ — „__ — ..-._ — — — — _.. — — — —. — — — — — -. — — — —. — — — — — — — — — — — — — — — — — — — — —•— — — — — — — — — — — — —


COMPANY NAME/SITE LOCATION  B.F. GOODRICH                                                    HENRY, IL
                                                                                                                   MARSHALL COUNTY



DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—  09/16/82
PERMIT NO. 82 03 0046                                                                         ESTIMATED DATE OF START-UP—   1985
DETERMINATION MADE BY       ILLINOIS EPA                   CHRIS ROMAINE                       (217J-7S2-2113
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)




PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... & BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... FCT EFF
BOILER, FLUIDIZED BED, RECIRCUL*
150.00 MKBTU/H
                                                          PM         0.0600  LB/MMBTU
                                                                            CYCLONE 4  BAGHOUSE
                                                          S02        1.2000  L6/r;^3TU
                                                                   85.0000  7.  REDUCTION
                                                                            FLUIDIZED  LIMESTONE BED
                                                          NOX        0.6000  LB/^:BTU
                                                                            EQUIPMENT  DESIGN
                                                          CO      400.0000  PFM
                                                                            EQUIPMENT  DESIGN
                                                                                         BACT
                                                                                         99.00
                                                                                         BACT
                                                                                         BACT

                                                                                         BACT
NOTES 	
CO EMISSION IS SUBJECT TO REVISION BASED  UPON RESULTS OF TRIAL OPERATION.
(»> INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G-  11
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW STATUS:  04/01/1933
                  ID  NCM3ER IL-0021
                                                                       SOURCE TYPE CODE
                                                                                            1.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1934
SOURCE TYPE/SIZE —
                            EXTERNAL COMBUSTION  - COAL
                                                                                           6507.00 MMBTU/H
COMPANY NAME/SITE LOCATION  CAJUN ELECT.  POWER COOP.
                                                                                        COUSHATTA, LA
                                                                                                                 RED RIVER PARISH
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT NO. (REGION FILE NO.) PSD-LA-106
DETERMINATION MADE BY       EPA REGION VI
                             (AGENCY)
     JOHN BUNYAK
  (AGENCY CONTACT PERSON)
                                         DATE OF PERMIT ISSUANCE—  03/25/80
                                         ESTIMATED DATE OF START-UP—   1935
                                                                                                  ( PHONE )
PROCESSES SUBJECT THROUGHPUT POLLUTANT
TO THIS PERMIT CAPACITY EMITTED
BOILER, LIGNITE FIRED 6507.00 MMBTU/H
PM

S02

NOX

CO

EMISSION LIMITS ... t BASIS
CONTROL EQUIPMENT OR PROCESS MODIFICATION ... PCT EFF

0.0300 LB/MMBTU
ELECTROSTATIC PRECIPITATOR
1.0800 LB/MM3TU
LIME/LIMESTONE SCRUBBER
0.6000 LB/fiMBTU
02 CONTROL
0.0900 LB/MM3TU
02 CONTROL

NSPS
99.95

80.00




COAL PILES
COAL HANDLING
LIME/LIMESTONE HANDLING AND PIL*
     PM       20.7000 LB/H
                      COMPACTION, CRUSTING AGENT

     PM        1.6000'LB/H
                      BAG FILTER

     PM        2.1000 LB/H
                      BAG FILTER
                                                                                                                            99.90
                                                                                                                            99.90
NOTES 	
A REQUEST FOR PERMIT MODIFICATION WAS RECEIVED AND IS CURRENTLY UNDER REVIEW. BACT WILL BE CHANGED. S02 LIMIT MAY BE EXPRESSED
(*) INDICATES DATUM WAS TRUNCATED FOR THIS  TABLE.

PAGE G-  12
                                                                                                     INITIAL REVIEU  POST STARTUP
                                                                                        REVIEW STATUS;  04/01/1933
ID NUMBER LA-0006
                                                     SOURCE TYPE CODE    1.1

-------
AS 0.6 LB/MKBTU, 30-DAY ROLLING AVG.
                                                                                                      INITIAL  REVIEW  POST STARTUP
<*) INDICATES DATUM WAS TRUNCATED  FOR THIS TABLE.                                        REVIEW STATUS:   04/01/1933
- — - — - — 3 —r~r = ±rr~z = rzzr = zr~ = -rrzrrsrzrzssr = z = -~z —— — — - — = = — — = - — = — — — — —= — — = = = = = = = = = = = = = = —— — — — — —~ = —— — — —— —= = -:= = =	—	~~	~"
PAGE G-  13                                          ID NUMBER LA-0006                                     SOURCE  TYPE COOE    1.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/22/1934
SOURCE TYPE/SIZE---
                            EXTERNAL COMBUSTION - COAL
                                                                                           6781.00 KMBTU/H
COMPANY NAME/SITE LOCATION  CENTRAL POWER  &  LIGHT
                                                                                           FANNIN, TX
                                                                                                                    GOLIAD COUNTY
DETERMINATION IS BACT FOR A MODIFIED SOURCE.
PERMIT NO. (REGION FILE NO.) PSD-TX-365
DETERMINATION HADE BY       EPA REGION VI
                             (AGENCY)
   JOHN BUNYAK
(AGENCY CONTACT PERSON)
                                                                                              DATE OF PERMIT ISSUANCE—  10/19/81
                                                                                              ESTIMATED DATE OF START-UP—    1933
                                                                                              (2141-767-1594
                                                                                                  ( FHCNE )
PROCESSES SUBJECT THROUGHPUT POLLUTANT EMISSION LIMITS ... 8 BASIS
TO THIS PERMIT CAPACITY EMITTED CONTROL EQUIPMENT OR PROCESS MODIFICATION ... PCT EFF
COAL FIRED BOILER 6781.00 MMBTU/H
PM 0.0300

S02 0.3900

NOX 0.5000

CO 0.0600

COAL DUMPER, ROTARY 11000.00 T/D COAL
PM 29.7600
149.8000

CONVEYOR TO SAMPLE HOUSE
PM 2.4000
11.7500

CONVEYOR TO ACTIVE PILE
PM 2.2500
2.2500


LB/MMBTU
ELECTROSTATIC PRECIPITATOS
LS/Kr.3TU
FLUE GAS DESULFURIZATION
LB/MN3TU
FIRE BOX DESIGN & 02 CONTROL
LB/MMBTU
02 CONTROL OPTIMAL WITH NOX

LB/H
LB/D
WET SUPPRESSION

LB/H
LB/D
COVERS, WET SUPPRESSION

LB/H
LB/D
TELESCOPIC CHUTE

NSPS
99.60
NSPS
99.60
NSFS

BACT


BACT

50.00

BACT

99.00

BACT

99.00
                                                                           COVERS, WET SUPPRESSION
PAGE G-  14

-------
(CONTINUED)  CENTRAL POWER  &  LIGHT
PROCESSES SUBJECT THROUGHPUT
TO THIS PERMIT CAPACITY
ACTIVE COAL PILE


INACTIVE COAL PILE


COAL CONVEYOR TO TRANSFER HOUSE



COAL CONVEYOR TO BOILER



FLYASH HANDLING




LIMESTONE CAR DUMP



LIMESTONE CONVEYOR TO STORAGE



LIMESTONE CONVEYOR TO BINS



= = = = = = = = = r = = = = = = = r = = = = r = = sr = s = = = s = ::r = = = = = = = = = r = = = r=r = = = = = :: = = = = = = :::r
POLLUTANT EMISSION LIMITS
EMITTED CONTROL EQUIPMENT OR PROCESS MODIFICATION

PM 5.7800 LB/H
COMPACTION & WET SUPPRESSION

PM 2.5000 LB/H
COMPACTION

PM 2.3200 LB/H
6.7200 LB/D
COVERS, WET SUPPRESSION

PM 4.6300 LB/H
13.4400 LB/D
COVERS, WET SUPPRESSION

PM 0.2800 LB/H
1.7000 LB/D
BAG FILTERS
PNEUMATIC CONVEYOR TO SILO

PM 2.7000 LB/H
24.2900 LB/WK
NONE

PM 0.3500 LB/H
3.1200 LB/WK
COVERED BAG COLLECTOR

PM 0.4000 LB/H
3.6000 LB/UX
COVERED BAG COLLECTOR
... £ BASIS
... PCT EFF

BACT


BACT
90.00

BACT

99.00

BACT

99.00

BACT

99.00


BACT



BACT

98.00

BACT

93.00
PAGE G-  15

-------
(CONTINUED) CENTRAL POWER 4 LIGHT
PROCESSES SUBJECT
TO THIS PERMIT
LIMESTONE STORAGE PILE


LIMESTONE RECLAIM



COAL SAMPLE HOUSE



COAL TRANSFER HOUSE




LIMESTONE SILOS



LIMESTONE TRANSFER HOUSE



THROUGHPUT POLLUTANT EMISSION LIMITS
CAPACITY EMITTED CONTROL EQUIPMENT OR PROCESS MODIFICATION

PM 0.0480 LB/H
NONE

PM 19.9000 LB/H
179.5200 LB/HK
NONE

PM 7.0000 LB/H
34.3000 LB/D
WET SUPPRESSION & COVERED CONVEYORS

PM 7.0000 LB/H
34.3000 LB/D
COVERED CONVEYORS
WET SUPPRESS.* COVERED CONVEY.

PM 0.3500 LB/H
3.1500 LB/WK
BAG FILTER

PM 0.1900 LB/H
1.7100 LB/KK
BAG FILTER
... & BASIS
... PCT EFF

BACT


BACT



BACT

99.00

BACT

99.00


BACT

99.00

BACT

99.00
                                                                           ENCLOSED CONVEYOR
NOTES
(*> INDICATES DATUM WAS TRUNCATED FOR  THIS TABLE.


PAGE G-  16
             INITIAL KVIEW  POST STARTUP
REVIEW STATUS--  0^/01/1933
                                                     ID NUMBER TX-0009
                                                                                                          SOURCE TYPE CODE
                                                                                                                              1.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/22/1984
SOURCE TYPE/SIZE—-
EXTERNAL COMBUSTION - COAL
                                                                                           1200.00 MW
COMPANY NAME/SITE LOCATION  CINCINATI GAS t ELECTRIC CO. - EAST BEN*
                                                                                                   KY
DETERMINATION IS BACT FOR A MODIFIED  SOURCE.
PERMIT NO.  0-82-072
DETERMINATION MADE BY       KENTUCKY  DAPC
                             (AGENCY)
                              B&LL OfLLS
                            (AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE—  05/14/82
                                       ESTIMATED DATE OF START-UP—   1981
                                       (502)-564-33S2
                                           (FHCNE)
PROCESSES SUBJECT
TO THIS PERMIT
          THROUGHPUT
           CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
& BASIS
PCT EFF
WIT 82
                                   6313.00 MM3TU/H
UNIT 81
                                   6270.00 MMBTU/H
                               PM         0.1000  LB/MMBTU
                                      2970.0000  T/YR
                                                ESP,  WET SCRUBBER
                               S02        1.2000  LB/MMBTU
                                     35640.0000  T/YR
                                                WET SCRUBBER
                               NOX        0.7000  LB/MMBTU
                                     20790.0000  T/YR

                               PM         0.1000  LB/MMBTU
                                      1650.0000  T/YR
                                                ESP
                               S02        0.8400  LB/MMBTU
                                     13860.0000  T/YR
                                                WET SCRUBBER
                               NOX        0.7000  LB/MMBTU
                                     11550.0000  T/YR
                                                                                                                             99.60
                                                                                                                             81.50
                                                                                                                             99.50
                                                                                                                             85.00
NOTES 	
PERMIT COVERS ONLY UNIT S2. UNIT SI CONSTRUCTION  PERMIT C-78-51 ON 8/25/78
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G-  17                                           ID NUMBER KY-0030
                                                                                                      INITIAL  REVIEW  POST STARTUP
                                                                                        REVIEW  STATUS;   04/01/1933    02/13/1934
                                                                               SC'JPCE TYPE CODE    1.1

-------
 EST. DATE OF START-UP UNIT *1 IS 01/86.
                                                                                                     INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED  FOR  THIS TABLE.                                        REVIEW STATUS:   04/01/1933    02/13/1984
PAGE G-  18                                          ID NUMBER KY-0030                                    SOURCE TYPE CODE    1.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE—-         EXTERNAL  COMBUSTION - COAL                                        92.50 MMBTU/H


COMPANY NAME/SITE LOCATION  CITY OF WILKES-BARRE                                      WILKES-BARRE, PA
                                                                                                                    LUZERUE COlflfTY
                           — ^____ —^___ —— „____ — ___ — — —__— — — — __ — — — _ — — — — —. — — — — — •- — — — — — — — — — —~ —— — — — — — — — — — — — — — — — — — — — — — — — — — — — — —— — — — — —— — — —— — —— ~

DETERMINATION IS BACT FOR A MODIFIED  SOURCE.                                                   DATE OF PERMIT ISSUANCE--  07/01/80
PERMIT NO. 79PA23                                                                             ESTIMATED DATE OF START-UP—   1980
DETERMINATION MADE BY       EPA REGION III                 DAVID ARNOLD                        ( 215J-597-793&
                             (AGENCY)                  (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                    THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... & BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF


BOILER                               92.50  MMBTU/H
                                                          PM        8.0000 LB/H                                              BACT
                                                                           BAGHCUSE/CYCLONE                                  99.70
                                                          S02     199.0000 LB/H                                              BACT
                                                                    1.5000 LB/MMBTU
                                                                           S IN FUEL


NOTES 	














                                                                                                      INITIAL REVIEW  POST STARTUP
(*> INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEW  STATUS:   04/01/1983

PAGE G-  19                                           ID NUMBER PA-0020                                     SOURCE  TYPE CODE    1.1

-------
                                             APPENDIX —  DETAILED  SOURCE LISTING
                                                                                                                        05/32/1984
SOURCE TYPE/SIZE— EXTERNAL COMBUSTION - COAL
COMPANY NAME/SITE LOCATION COLORADO UTE-CRAIG UNIT 93

DETERMINATION IS FOR A MODIFIED SOURCE.
PERMIT NO.
DETERMINATION MADE BY EPA REGION VIII
( AGENCY )
PROCESSES SUBJECT THROUGHPUT
TO THIS PERMIT CAPACITY
RR CAR 1.87 MMT/YR


ASH SILO VENT 355.00 MT/YR


ASH UNLOAD 355.00 MT/YR


BOILER, 440 MW 214.00 T/H











NEAR



JOHN DALE
(AGENCY CONTACT PERSON)
POLLUTANT EMISSION LIMITS
1320.00 MW
CRAIG, CO
MOFFAT COUNTY
DATE OF PERMIT ISSUANCE-- 03/27/80
ESTIMATED DATE OF START-UP— •
(303)-837-3763
( PKOUE )
... & BASIS
EMITTED CONTROL EQUIPMENT OR PROCESS MODIFICATION ... PCT EFF

PM 1.0000 T/YR
FF

PM 149.0000 T/YR
FF

PM 34.0000 T/YR
HYDROMIXER

CO
NO CONTROL
VOC
NO CONTROL
NOX 0.5000 LB/W.STU
BOILER DESIGN
PM 0.0300 LB/MM3TU
BAGHOUSE
S02 0.2000 LB/KM3TU
DRY SCRUBBER

BACT
99.80

BACT
99.80

BACT
59.00

BACT

BACT

BACT
65.00
BACT
99.60
BACT
90.00
PAGE G-  20

-------
(CONTINUED) COLORADO UTE-CRAIG UNIT 83
PROCESSES SUBJECT
TO THIS PERMIT
 THROUGHPUT
  CAPACITY
POLLUTANT    EMISSION LIMITS
 EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION
* BASIS
PCT EFF
COAL PILE
CONV.
LIME TRANS./STORAGE
TRANS PTS.
 1.87 MMT/YR


 1.87 MMT/YR


37.40 MT/YR


 1.87 MMT/YR
                                                          PM
                                                          PM
                                                          PM
                                                          PM
             5.0000 T/YR
                    SURFACTANT

             5.0000 T/YR
                    ENCLOSURES

             0.0000 T/YR
                    FF

             0.0000 T/YR
                    ENC + FF
  BACT
  85.00

  BACT
  90.00

  BACT
  99.80

  BACT
  99.80
NOTES
(*> INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G-  21
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW STATUS:  04/01/19S3
                 ID NUMBER CO-0007
                                                                      SCU3CE TYPE CODE    1.1

-------
                                             APPENDIX  — DETAILED SOURCE  LISTING
                                                                                                                        05/22/1934




SOURCE TYPE/SIZE---         EXTERNAL COMBUSTION -  COAL                                       137.00  MMBTU/H
                           		

COMPANY NAME/SITE LOCATION  CURTISS-KRIGHT CORP.                                        WOOD-RIDGE,  NJ  07075
                            1 PASSAIC ST.                                                                             BERGEN COUNTY


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE  OF  PERMIT  ISSUANCE—  06/13/80
PERMIT NO.                                                                                     ESTIMATED  DATE  Or  START-UP--
DETERMINATION MADE BY       EPA REGION II                  STEVE RIVA                           (212J-264-S6S4
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (FHONE)



PROCESSES SUBJECT                     THROUGHPUT       POLLUTANT    EMISSION  LIMITS                                    ...& BASIS
TO THIS PERMIT                         CAPACITY         EMITTED             CONTROL EQUIPMENT OR PROCESS  MODIFICATION  ...  PCT EFF
_ _	„ _ —	_.. _	— — _	— — —	— —	— — —	-- —	— — __ — — —	—	..__	— — — —	— — — —	— — — -. — — — — — —	— — —	__ — — — — _ — — —	_„ — _«._ — — — — — —

PFB BOILER                          137.00 MMBTU/H
                                                          S02       0.3000  LB/MMBTU                                          SIP
                                                                            PROCESS MOD.                                      93.00
                                                                            CALCIUM/SULFUR, 2/1
                                                          PM                NONE
                                                                            PROCESS CYCLONES
                                                          NOX               NONE
                                                          CO                NONE


NOTES 	
TEMPORARY SOURCE - NOT TO OPERATE IN EXCESS OF 3100 H/YR FOR A PERIOD  NOT TO EXCEED TWO YEARS FROM  START-UP.












                                                                                                      INITIAL  REVIEU  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:  04/01/19S3

PAGE G-  22                                           ID NUMBER NJ-OOO^f                                     SOURCE TYPE CODE    1.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/198*
SOURCE TYPE/SIZE—         EXTERNAL  COMBUSTION - COAL                                       550.00 MW


COMPANY NAME/SITE LOCATION  DELMARVA  POWER 8 LIGHT                                          VIENNA, HD 21869
                                                                                                                DORCHESTER  COUNTY


DETERMINATION IS BACT FOR A MODIFIED  SOURCE.                                                   DATE OF PERMIT ISSUANCE—   09/30/81
PERMIT NO. 80HT201                                                                             ESTIMATED DATE OF START-UP--    1983
DETERMINATION MADE BY       EPA REGION  III                 VERNON BUTLER                       (2151-597-8711
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                    THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ...  & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ...  PCT EFF
BOILER
                                   5702.00 MMBTU/H
BOILERS & STORAGE PILES
                                      1.20  HMT/YR
     S02        0.6000 LB/M3TU
              70.0000 •/. EMISSION REDUCTION
                      SCRU3BER
     NOX        0.6000 LB/M3TU
              65.0000 •/. EMISSION REDUCTION
                      BURNER DESIGN
     CO        0.0400 LB/MBTU
                      BURNER DESIGN
     VOC        0.0100 LB/K3TU
                      BURNER DESIGN
     VE       20.0000 •/. OPACITY STACK

     PM        0.0300 LB/M3TU
                      ESP
                      DUST-SUPPRESSANT LIQUID
                                                                                                                             BACT

                                                                                                                             90.00
                                                                                                                             BACT
BACT

BACT

BACT

BACT
99.65
NOTES
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G-  23
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                                S.ATU5:   0^/01/1983
ID NUMBER MD-000^
                                                     SCU.7CE TYPE CODE
                                                                         1.1

-------
                                             APPENDIX  —  DETAILED  SOURCE  LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE	
                            EXTERNAL COMBUSTION -  COAL
                                                                                             800.00 MW
COMPANY NAME/SITE LOCATION  DESERET GEN & TRANS,  MOON  LAKE
                                                                                      NEAR BONANZA, UT
                                                                                                                     UINTAH  COUNTY
DETERMINATION IS
PERMIT NO.
DETERMINATION MADE BY
                            EPA REGION VIII
                             (AGENCY)
   JOHN DALE
(AGENCY CONTACT PERSON)
DATE OF PERMIT ISSUANCE--  02/04/60
ESTIMATED DATE OF START-UP--   19S4
(303J-S37-3763
    (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
COAL CONV



COAL CRUSHER



COAL STORAGE



LIMESTONE HAND.



BOILERS, COAL-FIRED, 2 EA





THROUGHPUT POLLUTANT
CAPACITY EMITTED
475.00 T/H COAL
PM

VE
2.70 MMT/YR
PM

VE
2.70 MMT/YR
PM

VE
55.60 MT/YR
FM

VE
400.00 MW
CO

VOC

NOX
EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

1.0000 T/YR
ENC t FF
20.0000 y. OPACITY

1.0000 T/YR
ENC i FF
20.0000 7. OPACITY

2.0000 T/YR
WET SUP
20.0000 •/. OPACITY

1.0000 T/YR
ENC & FF
20.0000 '/. OPACITY


NO CONTROL

NO CONTROL
0.5500 LB/N"BTU
... & BASIS
... PCT EFF

BACT
99.00


BACT
99.00


BACT
50.00


BACT
90.00


BACT

BACT

BACT
PAGE G-  24

-------
                                                                           BOILER DESIGN
                                                          PM        0.0300 LB/MMBTU
                                                                    0.0200 GR/DSCF
                                                                           FF
                                                          S02     418.0000 LB/H
                                                                    0.0550 LB/KMBTU
                                                                           WET SCRUBBER
                                                          VE       20.0000 7. OPACITY
                                          99.60
                                          BACT

                                          99.60
                                          BACT

                                          94.00
NOTES 	
CEH QA REQUIRED BY 40CFR, PART 60, SUBPART  DA. BOILER EMISSION COMPLIANCE FOR S02,
RTS. VE IS STATEPERMIT REQUIREMENT.
NOX, OPACITY WILL BE DETERMINED BY CEM REPO
(*) INDICATES DATUM WAS TRUNCATED  FOR THIS TABLE.

PAGE 6-  25
                   INITIAL ftVIEW  POST STARTUP
      REVIEW STATUS:  04/01/1°S3
                                                     ID NUSER UT-0006
                                                                                                          SOURCE TYPE CCDE
                                                                                                                              1.1

-------
                                             APPENDIX  — DETAILED  SOURCE  LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE—         EXTERNAL COMBUSTION -  COAL                                        526.00  HW MOD.


COMPANY NAME/SITE LOCATION  EAST KENTUCKY POWER COOP.                                     MAYSVILLE,  KY 40391
                            P.O. BOX 707                                                                              MASON COUNTY
                           		— — —	— -,— _ — — —	— — —	—	— — —	— —	_-._ __	— —	— —	— —	— — — —	— — — — —

DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE  OF PERMIT  ISSUANCE—   12/02/76
PERMIT NO. C-76-46                                                                             ESTIMATED  DATE  OF  START-UP—   1931
DETERMINATION MADE BY       KENTUCKY DAPC                 BILL DILLS                           (502J-564-3332
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ...  & BASIS
TO THIS PERMIT                         CAPACITY         EMITTED            CONTROL EQUIPMENT OR PROCESS  MODIFICATION   ...  PCT EFF
__»_.._„.„.„.-	__	_.- — _.	— _._	__—..__:	— _ —	——-.— — — —	—	-._ —	— ~ — — —	— _«•-,	__ — —_	_-._—_..	— —	—	— — —

BOILER, PULV., COAL FIRED, DRY *   6760.00 MMBTU/H
                                                          PM        0.1000 LB/MMBTU
                                                                           HOT  SIDE ESP                                      99.50
                                                          PB
                                                                           HOT  SIDE ESP                                      99.50
                                                          S02       1.2000 LB/MM3TU
                                                                           0.72X S IN FUEL
                                                          CO
                                                          NOX       0.7000 LB/M!'i3TU


NOTES 	
UfUT NlfMBER 2










                                                                                                      INITIAL  REVIEW  POST  STARTUP
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEW STATUS:  C4/01/1933     02/13/1934

PAGE G-  26                                          ID NUMBER KY-0018                                    SOLACE T\PE CODE    1.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE---         EXTERNAL COMBUSTION - COAL                                       670.00 MMBTU/H


COMPANY NAME/SITE LOCATION  EASTMAN KODAK CO., KODAK PARK DIV.                           ROCHESTER, NY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF  PERMIT  ISSUANCE—  13/20/82
PERMIT NO. C262800 025 00004                                                                  ESTIMATED  DATE  OF  START-UP—    1936
DETERMINATION MADE BY       NEW YORK DEC                   FRANK SHATTUCK                      (716)-£26-246&
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PhCNE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                    ... & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS  MODIFICATION  ... PCT EFF
BOILER, COAL FIRED
670.00 MMBTU/H
COAL CAR UNLOADER
CRUSHING
BUNKER
                       PM

                       S02

                       NOX

                       CO

                       BE


                       PM


                       PM


                       PM
0.0350 LB/MMBTU
       ESP
1.2000 LB/MM3TU
       LOU S COAL
0.7000 L6/MM3TU
       CCM3USTION CONTROL
o.o<+50 LB/M;;BTU
       COMBUSTION CONTROL
0.0010 LB/H
       ESP

1.1000 LB/H
       FABRIC FILTER

0.7500 LB/H
       FABRIC FILTER

0.0230 LB/H
BACT
99.57
BACT

BACT

BACT

BACT
98.40

BACT
99.00

BACT
99.00

BACT
PAGE G-  27

-------
(CONTINUED) EASTMAN KODAK CO.,  KODAK PARK DIV.
PROCESSES SUBJECT                     THROUGHPUT         POLLUTANT    EMISSION  LIMITS                                    ...  8 BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ...  FCT  EFF


ASH HANDLING
                                                          PM        0.0750 LB/H                                             BACT
                                                                           FABRIC FILTER                                    99.00
NOTES
                                                                                                     INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:  04/01/1983

PAGE 6-  28                                          ID NUMBER NY-0004                                    SOURCE TYPE CODE    1.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/22/1984
SOURCE TYPE/SIZE---
                            EXTERNAL COMBUSTION - COAL
                                                                                            600.00 MW, 2 EA
COMPANY NAME/SITE LOCATION  E. KENTUCKY POWER CORP.
                            J.K.  SMITH POWER STATION
                                                                                            TRAPP, KY
                                                                                                                     CLARK COUNTY
DETERMINATION IS BACT FOR A NEW  SOURCE.
PERMIT NO. C-80-67
DETERMINATION MADE BY       KENTUCKY DAPC
                             (AGEUCY)
                                                          BILL DILLS
                                                       (AGENCY CONTACT PERSON)
DATE OF PERMIT ISSUANCE—  08/21/80
ESTIMATED DATE OF START-UP--   1992
(5C2)-564-33S2
    (PHOHE)
PROCESSES SUBJECT THROUGHPUT POLLUTANT EMISSION LIMITS ... 8 BASIS
TO THIS PERMIT CAPACITY EMITTED CONTROL EQUIPMENT OR PROCESS MODIFICATION ... PCT EFF
BOILER, COAL FIRED 6760.00 MMBTU/H EA
PM 0.0300 LB/MMBTU
ESP
S02 1.2000 LB/MMBTU
WET SCRUBBER
NOX 0.6000 LB/MHBTU
BOILER DESIGN
BOILER, COAL FIRED 6760.00 MKBTU/H
PM 0.0300 LB/MMBTU
ESP
S02 1.2000 LB/MMBTU
WET SCRUBBER
NOX 0.6000 LB/MMBTU
BOILER DESIGN

BACT
99.80
BACT
90.00
BACT


BACT
99.80
BACT
90.00
BACT

NOTES 	
STARTUP UNIT 1, 8/92 UNIT 2, 8/93
 («) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

 PAGE G-  29
                                                                                                     INITIAL REVIEW   POST  STARTUP
                                                                                        REVIEW STATUS:   04/01/1933
                                                      ID NUMBER KY-OC03
                                                                                                           SOURCE  TYPE  CODE
                                                                                                                               1.1

-------
                                             APPENDIX  — DETAILED  SOURCE  LISTING
                                                                                                                        05/23/1934



SOURCE TYPE/SIZE—         EXTERNAL COMBUSTION -  COAL                                      1220.00  BTU/H


COMPANY NAME/SITE LOCATION  FLORIDA POWER CORP.                                CRYSTAL RIVER,  FLA.,  FL 33733
                                                                                                                     CITRUS COUNTY


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE  OF PERMIT ISSUANCE--  01/15/80
PERMIT NO. AC52-36102                                                                          ESTIMATED DATE OF START-UP—   1933
DETERMINATION MADE BY       FLORIDA DER                    BOB  KING                             < 904 )-4S3-134<*
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION LIMITS                                   ... & BASIS
TO THIS PERMIT                         CAPACITY         EMITTED            CONTROL EQUIPMENT  OR PROCESS MODIFICATION  ... PCT EFF
„__ _	_»_ —	__.. — -. —	— —	______ — ____ — ..—__	— — — — —	— — — — — —	___-,_____ —	— — — __	____ — -. — __ — — .....,	«._ — — __	— ____	____ — ._	—.

FLY ASH HANDLING UNITS            55000.00 LB/H
                                                           PM         4.0000  LB/H                                              BACT
                                                                            BAGHOUSE                                         99.90


NOTES 	
ADDED ESP TO EXISTING BOILER
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PiGE G-  30
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW STATUS:   04'01/19S3    01/25/1934
ID NUMBER FL-0013
                                                     SCL'SCE TYPE CODE    1.1

-------
                                            APPENDIX -- DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE---         EXTERNAL COM3USTION - COAL                                        58.00 HW


COMPANY NAME/SITE LOCATION  GRAND  HAVEN BOARD OF LT 4 PRR                              GRAND HAVEN, MI 49417
                            HARBOR ISLAND                                                                          MUSKEGON  COUNTY


DETERMINATION IS BACT FOR A NEW  SOURCE.                                                        DATE OF PERMIT ISSUANCE—  03/18/80
PERMIT NO. 541-79                                                                             ESTIMATED DATE OF START-UP--    1933
DETERMINATION MADE BY       MICHIGAN DNR                   GREGORY EDWARDS                     (5171-322-1333
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                    THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    . . . « BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF


COAL-FIRED BOILER                  710.00 MMBTU/H
                                                          PM        0.0300 LB/MMBTU
                                                                           ESP                                               99.60
                                                          SO2       0.8400 LB/MHBTU 300 AV
                                                                    0.8000 LB/W3TU 24H AV
                                                                           LIME SLURRY WET SCRUBBER                          90.00
                                                          NOX       0.6000 LB/Mr.3TU 30D AV


NOTES 	













                                                                                                      INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED  FOR THIS TABLE.                                        REVIEW STATUS:   04/01/1933     03/13/1964

PAGE G-  31                                          ID NUMBER MI-0004                                     SOURCE  TYPE CODE     1.1

-------
                                             APPENDIX  —  DETAILED  SOURCE LISTINS
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE	         EXTERNAL COMBUSTION - COAL                                       490.00 MW
                           	«,	— — — __	— —	— — — — — —	—	—	— — — — —	— — — —	-._____.	— —

COMPANY NAME/SITE LOCATION  GRAND RIVER DAM AUTHORITY                                              . OK 74361
                                                                                                                      HAYES COUNTY
                           	__.__	— — — — —	,.__ — ____ — ..-._ —	—	—	— — —•	— — — —	—	— — —	— — —

DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—  03/30/78
PERMIT NO. PSD-CK-51                                                                           ESTIMATED DATE OF START-UP--
DETERMINATION MADE BY       EPA REGION VI                 JOHN BUNYAK                         (£14)-767-1594
                             (AGENCY)                  (AGENCY CONTACT PERSON)                    (PHONE)



FROCESSCS SUBJECT                     THROUGHPUT       POLLUTANT     EMISSION LIMITS                                   ... & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
	.	•	•	

COAL FIRED GEN STATION              490.00 MW
                                                          S02        1.2000 LB/MHBTU
                                                                  6157.2000 LB/H
                                                                            LOW S COAL
                                                          PM        o.iooo LB/nr:sTU
                                                                   513.1000 LB/H


NOTES 	














                                                                                                      INITIAL REVIEW  POST STARTUP
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:  04/01/1933
~~--~z~-~ = = ~~~~-~- = = ~ = = ~ ~- = = ^-~~ = ~~------~~ = ~--~--~'~~~~='~~ = ~~ = -~~ = ~ = ===-~~ = = = = ===~ = ~-~~=-^-----~~-~ = ~='~~-~~~~~~~~~~~~='~ = ~~~= ===~
PAGE G-  32                                           ID  HUt'BER OK-0001                                    SOURCE TYPE CODE    1.1

-------
                                            APPENDIX  — DETAILED SOURCE  LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE — -         EXTERNAL COMBUSTION  - COAL


COMPANY NAME/SITE LOCATION  HOLVOKE WATER  POMER  CO., MT. TOM PUR  PL*                        HOLYOKE,  MA


DETERMINATION IS PACT FOR A MODIFIED SOURCE.                                                    DATE  OF PERMIT ISSUANCE—  10/27/82
PERMIT NO. AFPR. LTR 10-27-82                                                                  ESTIMATED DATE OF START-UP--   1981
DETERMINATION MADE BY       MASSACHUSETTS  DEQE - AIR       DAVID  HOWLAND                        (617)-727-8640
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     ( FHCNE )



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                   ... 4 BASIS
TO THIS PEP-MIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT OR PROCESS MODIFICATION  . . . PCT EFF


COAL COMBUSTION                    1447.00 MM8TU/H
                                                          S          1.2100  LB/MMBTU MONTHLY AV                              PACT
                                                                     1.6000  LB/MM3TU DAILY AV
                                                          PM         O.OSOO  LB/HH3TU                                         PACT
                                                                            ESP                                               99.51
                                                          NOX


NOTES 	
Of.'E UNIT - 155 MM. VOLUNTARY COAL CONVERSION














                                                                                                      INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEW STATUS:  04/01/1983

PAGE G-  33                                          ID N'JtiSER MA-OC05                                     SOURCE TYPE CODE    1.1

-------
                                             APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                         05/22/1934



SOURCE TYPE/SIZE—          EXTERNAL COMBUSTION - COAL                                        550.00 MW


COMPANY NAME/SITE LOCATION   HOUSTON LIGHTING * POWER                                        HOUSTON, TX
                           —	—	—	—	—	—	—	— —	—	— —	— —	— — — — -. — — .._,___	_	___	— —	_	___	— __-. —	___ — ..___..___,_

DETERMINATION IS BACT FOR A  NEW SOURCE.                                                         DATE OF PERMIT ISSUANCE—  10/28/77
PERMIT NO. PSD-TX-33                                                                            ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY        EPA REGION VI                  TOM DIGGS                            (214 )-767-1594
                              (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHCNE )



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ...& BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ... PCT EFF
— — — •—— — — — — — — — — — — — — — — — — —-•— — -• — — •-•- — —». — — — — ___ — — _ — _..__..__»,.__ _ — — — -.___.. ____..— __„ ____ ________ — _ __• __„.«. ___„ _ ___ — — __., ____ ___„. __„. ^. __^____—.«__ — _

COAL FIRED STEAM ELECT. GEN         550.00 MW
                                                           S02       1.2000 LB/MMBTU
                                                                   573.0000 LB/H
                                                                            LOM S WESTERN COAL
                                                           PM        0.1000 LB/M"3TU


NOTES		
(*> INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G-  34
             INITIAL S^-IVIEW   POST  STARTUP
REVIEW STATUS;  04/01/1933
                                                      ID NUI13ER TX-0005
                                                                                                           SOURCE  TYPE  CODE
                                                                                                                                1.1

-------
                                            APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                        05/32/1984
SOURCE TYPE/SIZE —
                            EXTERNAL COMSUSTION - COAL
                                                                                            550.00  MM
COMPANY NAME/SITE LOCATION  HOUSTON LIGHTING & POWER
                                                                                        THOMPSONS,  TX
                                                                                                                  FORT BEND COUNTY
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT HO. PSD-TX-234
DETERMINATION MADE BY       EPA REGION VI
                             (AGENCY)
                     JOHN BUNYAK
                  (AGENCY CONTACT PERSON)
                                                         DATE OF PERMIT ISSUANCE—  11/12/81
                                                         ESTIMATED DATE OF START-UP—
                                                                                                   ( PHONE )
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
& BASIS
PCT EFF
COAL FIRED BOILER
                                   5729.00 MMBTU/H
LIMESTONE UNLOAD
ACTIVE LIMESTONE PILE
INACTIVE LIMESTONE PILE
                     S02        0.3600 LB/MMBTU
                                      LIMESTONE SCRU3BER
                     NOX        0.5000 LB/MM3TU
                                      02 CONTROLS, TANGENTIAL BURNERS
                     CO        0.0590 LB/MM3TU
                                      02 CONTROLS
                     PM        0.0300 LB/r.r
-------
(CONTINUED) HOUSTON LIGHTING & POHER
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT    EMISSION LIMITS
 EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION
& B4SIS
FCT EfF
LIMESTONE CONVEYERS fc TRANSFER *
LIMESTONE CRUSHER
LIMESTONE FEED SILO
FLY ASH MIX TANK
                                                           PM
                                                           PM
                                                           PM
                                                           PM
                               0.5000 LB/H
                                      ENCLOSED

                               0.1000 LB/H
                                      BAGHOUSE

                               0.1000 LB/H
                                      BAGHOUSE

                               0.7000 LB/H
                                      WILL BE A SLURRY
                                                                     BACT
                                                                     90.00

                                                                     BACT
                                                                     99.50

                                                                     BACT
                                                                     99.50

                                                                     BACT
NOTES
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G-  36
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW STATUS:   04/01/1933
                ID  NUI1EER  TX-0011
                                                                     SOL'SCE TYPE CCDE    1.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE-—         EXTERNAL COMBUSTION - COAL                                       727.00 MM


COMPANY NAME/SITE LOCATION  IA SOUTHERN UTILITIES (CENTERVILLE, IA.)            (NEAR) CHILLICOTHE, IA
                            OTTUMWA STATION                                                                         WAFELLO  COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT  ISSUANCE—  12/01/76
PERMIT NO.                                                                                    ESTIMATED DATE  OF START-UP—    1980
DETERMINATION MADE BY       EPA REGION VII                 CHARLES WHITMORE                    (816J-374-6525
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHOHE)



PROCESSES SUBJECT                    THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... & BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF


BOILERi STEAM GEN, COAL FIRED
                                                          S02       1.2000 LB/MMBTU                                          BACT
                                                                           LOU S COAL
                                                          PM        0.1000 LB/MMBTU                                          BACT
                                                                           ESP


NOTES 	
THE PERMIT WAS AMMENDED ON 03/30/78 TO ADDRESS PARTICULATE MATTER.














                                                                                                     INITIAL  REVIEW   POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED  FOR THIS TABLE.                                        REVIEW STATUS:  04/01/1983

PAGE G-  37             i                             ID NUMEER IA-0007                                    SOURCE TYPE CODE     1.1

-------
                                             APPENDIX --  DETAILED SOURCE LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE---         EXTERNAL COMBUSTION - COAL                                       165.00 HMBTU/H
                           		„_____..	— _ —	—	— —	—	— —	—	— —	— —	—	— — _	

COMPANY NAME/SITE LOCATION  IDAHO NAT ENGINEERING LAB.                                 IDAHO FALLS, ID
                           _ „ ... _ — __ ____. — _________ — — _____________ _•_ ______„ — »-___..____-___ — — -_«. — — — -.»- — — — •—•— — — — •• — __^__™ —— -.-» — — — _._ _ _ — — _ ______

DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—  06/05/81
PERMIT NO. (REGION FILE NO.) PSD-XS1-11                                                        ESTIMATED DATE OF START-UP—   1983
DETERMINATION MADE BY       EPA REGION X                   DAVID TETTA                         <206)-442-1193
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (FHCNE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... 8, BASIS
TO THIS PESMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF


BOILERS, 2                           82.50 M EA
                                                           S02      99.2000 LB/H                                             BACT
                                                                            FLUIDIZIED BED
                                                           NOX       0.5000 LB/MM3TU                                         BACT
                                                                            COMBUSTION CONTROLS
                                                           PM        0.0500 GR/DSCF                                          BACT
                                                                            BAGHOUSE                                         99.00
FUGITIVE EMISSIONS
                                                           PM        0.0100 GR/ACF
                                                                            BAGHOUSE                                         99.00


NOTES 	











                                                                                                      INITIAL REVIEW  POST STARTUP
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:  0^/01/1933

PAGE G-  38                                           ID NUMBER 10-0002                                    SCARCE TYPE CODE    1.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/22/198*
SOURCE TYPE/SIZE—-
EXTERNAL COMBUSTION - COAL
                                                                                            980.00 MM
COMPANY NAME/SITE LOCATION  INDIANA STATEWIDE RURAL ELEC. COOP., ME*
                                                                                                 , IN
                                                                                                                  SULLIVAN COUNTY
DETERMINATION IS BACT FOR A NEW SOURCE.
PEPMIT NO.  EPA-5-77-A-7
DETERMINATION MADE BY       EPA REGION V
                             (AGENCY)
                              BONIFACE THAYIL
                            (AGENCY CONTACT PERSON)
                                                                  DATE OF  PERMIT  ISSUANCE—   06/28/77
                                                                  ESTIMATED  DATE  OF  START-UP—
                                           ( PHONE )
PROCESSES SUBJECT
TO THIS PEPMIT
          THROUGHPUT
           CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
& BASIS
PCT EFF
BOILER, COAL FIRED, 2 EA
                                    490.00 MM
                                                          PM
                                                          S02
                                         0.1000  LB/MMBTU
                                         1.2000  LB/ttMBTU
                                                                     NSPS
                                                                     NSPS
NOTES
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G-  39
                          ID NUMBER IN-0022
                                                                          INITIAL REVIEW  POST STARTUP
                                                             REVIEW STATUS;  04/01/1933

                                                                               SOURCE TYPE CODE    1.1

-------
                                             APPENDIX  -- DETAILED  SOURCE  LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE —
                            EXTERNAL COMBUSTION -  COAL
                                                                                            2600.00
COMPANY NAME/SITE LOCATION  INDIANA & MICHIGAN ELEC. CO., ROCKPORT  *
                                                                                          ROCKPORT,  IN
DETERHINATION IS BACT FOR A NEW SOURCE.
PEPMIT NO. EPA-5-78-A-1
DETERMINATION MADE BY       EPA REGION V
                             (AGENCY)
                     BONIFACE THAYIL
                  (AGENCY  CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE—  10/27/77
                                       ESTIM4TEO DATE OF START-UP--
                                       (3121-686-6054
                                           (FHOME)
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
& BASIS
PCT EFF
BOILER, COAL FIRED, 2 EA
                                   1300.00 MW
                                                           PM
                                                           S02
                               0.1000 LB/MMBTU
                               1.2000 LB/MfiSTU
                                                                     NSPS
                                                                     N'SFS
NOTES
(*> INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G-  40
                ID  NUMBER  IN-0023
                                                                INITIAL REVIEU  POST STARTUP
                                                   REVIEW  STATUS-'   0^/01/1933

                                                                     SOL'FCE TYPE CCDE    1.1

-------
                                             APPENDIX —  DETAILED SOURCE LISTING
                                                                                                                         05/22/1984



SOURCE TYPE/SIZE—         EXTERNAL COMBUSTION - COAL                                      1950.00 MW
                           __	„___	 _ —	___„___«.__ — — _ —	— _ — .._ — — — — — — — — — — _____ __ —	—	— -—. _ — — _———_— — — •, — — •. — ...— » — — — — — — — —

COMPANY NAME/SITE LOCATION  INDIANAPOLIS POUER & LIGHT CO., PATRIOT*                               • IN
                                                                                                                 SWITZERLAND COLfffTY
                           	~	

DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—  12/14/79
PERMIT NO. EPA-5-A-80-8                                                                        ESTIMATED DATE OF START-UP—
DETERMINATION MADE BY       EPA REGION V                   BONIFACE THAYIL                     <312J-8S6-6054
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... t BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT  OR PROCESS MODIFICATION  ... PCT EFF
	.	•	

BOILER, COAL FIRED, 3 EA            650.00 MW
                                                           PM        0.0300 LB/MMBTU
                                                           S02       0.5500 LB/re-STU
                                                                            SCRUBBER                                          91.00
                                                           NOX       0.6000 LB/M!i3TU


NOTES —	















                                                                                                       T..T-T-,,  nryyctj   POST  STARTUP
<*) INDICATES DATUM WAS TRUNCATED  FOR  THIS TABLE.                                         i-c.iL^  SIAi'US:   0-V01/19o3

PAGE G-   41                                            ^ •  •-•    •    -                                      .•-...,-£.  7ir£ CODE     1.1

-------
                                             APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE	
                            EXTERNAL COMBUSTION -  COAL
                                                                                            1640.00  KW
COMPANY NAME/SITE LOCATION  INTERKQUNTAIN POHER  PROJECT
                                                                                            LYKDLE,  UT
DETERMINATION IS BACT FOR A MODIFIED SOURCE.
PERMIT NO.
DETERMINATION MADE BY       UTAH BAQ
                             (AGENCY)
                     DAVID  KAPTA
                  (AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE—  10/17/83
                                       ESTIMATED DATE CF START-UP--   1985
                                       (801J-533-6103
                                           (PHCNE)
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
& BASIS
PCT EFF
BOILER, COAL FIRED, 3
                                   8352.00 MMBTU
COAL HANDLING, UNLOADING, CRUSH*      5.00 MMT/YR
COAL, LIMESTONE, ASH HANDLING
                                      5.00 MMT/YR
                     PM         0.0200  LB/MMBTU
                                      FABRIC  FILTER
                     S02        0.0150  LB/M!',3TU
                                      LIMESTCS'E  SCRUB
                     NOX        0.5500  LB/MtlBTU
                                      COMBUSTION CONTROL
                     VE        20.0000  7. OPACITY
                                      FABRIC  FILTER

                     PM         0.0240  G3/DSCF
                                      13 FABRIC  FILTERS
                     VE        20.0000  7. OPACITY
                                      13 FABRIC  FILTERS

                     VE        20.0000  y. OPACITY
                                      WET SUPPRESSION
                                                                                                                             BACT
                                                                                                                             99.80
                                                                                                                             BACT
                                                                                                                             90.00
                                                                                                                             BACT

                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             99.00
                                                                                                                             BACT
                                                                                                                             SACT
                                                                                                                             50.00
NOTES
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G-  42
                                                                                                      INITIAL  REVIEW   POST  STARTUP
                                                                                        REVIEW STATUS:
                ID  NUMBER  UT-0009A
                                                                     SCITCE  TYPE CODE
                                                                                         1.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE---         EXTERNAL COMBUSTION - COAL                                       3000.00  MW


COMPANY NAME/SITE LOCATION  INTERMOUNTAIN  PWR PROJECT-IPP                             NEAR  LYNNDYL,  UT
                                                                                                                    MILLARD COUNTY
                           __ ___«.___ _______ — _ — _ —„«__•_»_____ — -._-. — __-.-. — — — — — — — —. — — » — — — — — — — — — — — _ — — _—.—_ — — — — — _ — — ________ —__—__ __,-__.___ — _

DETERMINATION IS BACT FOR A NEW SOURCE.                                                         DATE  OF  PERMIT ISSUANCE--  06/03/80
PERMIT NO.                                                                                      ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY       EPA REGION VIII                JOHN DALE                            (303NS37-3763
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT         POLLUTANT    EMISSION LIMITS                                    ... * BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
ASH UNLOAD
4 BOILERS
COAL CONV
COAL CRUSHING
                                   3000.00  MM
                                     10.00 MMT/YR
                                     10.00 MMT/YR
PM

VE

CO
VOC
NOX

PM

S02

VE

PM

VE

PM

VE
  64.0000

  20.0000

1248.0000
 375.0000
   0.5500

   0.0200

   0.1500

  20.0000

  17.0000

  20.0000

   1.0000

  20.0000
LB/H
HYDEOMIXER
7. OPACITY

LB/H
LB/H
LB/MMBTU
DESIGN
LB/M"3TU
ESP
LB/MMBTU
SCRUE3ER
•/. OPACITY

LB/H
ENCLOSURE
7. OPACITY

LB/H
BAG-HOUSE
'/ OPACITY
                                                                                                                             BACT
                                                                                                                             99.00
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             65.00
                                                                                                                             BACT
                                                                                                                             99.80
                                                                                                                             EACT
                                                                                                                             90.00
                                                                                                                             BACT
                                                                                                                             90.00
                                                                                                                             BACT
                                                                                                                             99.60
PAGE G-  43

-------
(CONTINUED) INTERMCUNTAIN PUR FROJECT-IPP
PROCESSES SUBJECT
TO THIS PERMIT
COAL STORAGE



COAL UNLOAD



HAUL ROADS


LIME STORAGE



CONV/TRANSFER



THROUGHPUT POLLUTANT EMISSION LIMITS ...& BASIS
CAPACITY EMITTED CONTROL EQUIPMENT OR PROCESS MODIFICATION ... FCT EFF
10.00 MMT/YR
PM

VE
10.00 MMT/YR
PM

VE

PM


PM

VE
10.00 MMT/YR
PM

VE

27.0000

20.0000

2.0000

20.0000

1.0000


0.1000

20.0000

4.0000

20.0000

LB/H
CRUSHING MGMT
X OPACITY

LB/H
WET SUPFRES.
X OPACITY

LB/H
CHEM. SUPFRES.

LB/H
BAGHOUSE
•/. OPACITY

LB/H
BAGHOUSE
X OPACITY

BACT
90.00


BACT
98.50


BACT
85.00

BACT
99.60


BACT
9S.80

NOTES 	
THIS PROJECT IS UNDER CURRENT RE-REVIEW SINCE  THE PROJECT HAS BEEN DOWN SIZED TO Z UNITS VERSES THE ORIG.4. STRONGLY RECOMMEND
 THIS BE DELETED ANDWE WILL UPDATE THE ABOVE INFO AS SOON AS RE-EVALUATION IS COMPLETED (PROS. MAY 1983.
CEM QA REQUIRED BY 40CFR,  PART 60, SUBPART  DA.
(*> INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G-  4
-------
                                             APPENDIX  — DETAILED SOURCE  LISTING
                                                                                                                        05/22/1984




SOURCE TYPE/SIZE---         EXTERNAL COMBUSTION  - COAL                                       650.00 MW
                           	__	__„	__„___.,,_..--. — .. — —	__«,_^__ —•_ — »_ — — _. — — -. — — — — — — *•. — — «- — — —— — •^ — — —— — — —— — — — — — — — — — — — — — — — — — — —— ~ —


COMPANY NAME/SITE LOCATION  IOWA ELECTRIC LIGHT  * POWER CO.                                  PANORA, IA
                                                                                                                    GUTHRIE COUNTY
                           _•..,.._.__.___..__..__«___»_.«—..__•.__•••_» — —~r— — — — — — ——. — _ — — — — — — ^ —— — — — — — — —— — _«. — _._.• ___._ _— ____»_w _»__.»__»->__ __.__*._


DETERMINATION IS BACT FOR A NEW SOURCE.                                                         DATE OF PERMIT ISSUANCE—  10/29/82
PERMIT HO.                                                                                     ESTIMATED DATE Or START-UP--
DETERMINATION MADE BY       EPA REGION VII                STEVE  KOVAC                         (8161-374-6525
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)




PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... & BASIS
TO THIS PERMIT                         CAPACITY           EMITTED             CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
STEAM GENERATING COAL-FIRED BOI*    400.00 T/H COAL
MATERIAL HANDLING
     S02        0.6000 LB/MMBTU DAILY MAX
                      WET LIMESTONE SCRUBBER
                      LOW S COAL
     NOX        0.5000 LB/MUBTU 300 R AV
                      COMBUSTION DESIGN
     PM        0.0300 LB/MN3TU
                      ELECT. FRECIP.
     VE       20.0000 •/. OPACITY

     PM        0.0100 GR/DSCF
                      BAGHOUSES
     VE       20.0000 •/. OPACITY
BACT


BACT



BACT

BACT

BACT
NOTES 	
SOURCE IS SUBJECT TO NSPS, SUBPART DA
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G-  45
                                                                                                      INITIAL REVIEW   POST STARTUP
                                                                                         REVIEW STATUS:   04/01/1933
ID NUMBER IA-0011
                                                     SO'JRCE TYPE  CODE
                                                                          1.1

-------
                                             APPENDIX  -- DETAILED SOURCE  LISTING
                                                                                                                        05/22/1=34
SOURCE TYPE/SIZE—         EXTERNAL COMBUSTION -  COAL                                       600.00 MM


COMPANY NAME/SITE LOCATION  IOWA-ILLINOIS GAS  & ELECT.                                             , IA
                            LOUISA STATION                                                                           LOUISA  COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT  ISSUANCE—   06/16/81
PERMIT NO.                                                                                    ESTIMATED DATE  OF START-UP--    1983
DETERMINATION MADE BY       EPA REGION VII                CHARLES WHITMORE                    (816 )-374-6525
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE )



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                    ... t BASIS
TO THIS PERMIT                         CAPACITY         EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF


BOILER                             7000.00 MMBTU/H
                                                          NOX       0.6000 LB/MMBTU                                         BACT
                                                                           EOILER DESIGN
                                                          PM        0.0300 LB/MM3TU                                         BACT
                                                                           ESP
                                                          S02       0.8600 LB/ttfiSTU 24H AV                                  BACT
                                                                    1.0500 LB/rriBTU 3H AV
                                                                           LOW S COAL


NOTES 	
PERMIT ORIGINALLY ISSUED 07/07/79.

53600.0 LB/DAY TOTAL ALLOWED









                                                                                                     INITIAL  REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:  04/01/1933

PAGE G-  46                                          ID NUMBER IA-0002                                    SOURCE TYPE  CODE     1.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/32/1984



SOURCE TYPE/SIZE—-         EXTERNAL COMBUSTION - COAL                                       600.00 MM


COMPANY NAME/SITE LOCATION  JACKSONVILLE ELECT. AUTHORITY                             JACKSONVILLE, FL 32208
                            HORTHSIDE                                                                                  DUVAL COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT  ISSUANCE—   01/01/82
PERMIT NO. (REGION FILE NO.) PSD-FL-010                                                        ESTIMATED DATE  OF  START-UP—   1986
DETERMINATION MADE BY       FLORIDA DcR                    BOB KING                            (9C4 )-<+S8-1344
                             (AGENCY)                    (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT         POLLUTANT    EMISSION  LIMITS                                    ...» BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF


STEAM GEN. UNIT                    600.00  M4  EA
                                                          S02       0.7600 LB/MMBTU                                          BACT
                                                                           LIME/LIMESTONE  FGD                                90.00
                                                          PM        0.0300 LB/HM3TU                                          NSFS
                                                                           ESP                                               99.73
                                                          NOX       0.6000 LB/MMBTU                                          NSPS
                                                                           BOILER DESIGN


NOTES 	
TWO UNITS AT 600.0 MW EACH.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G-  47
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW STATUS:  04/01/1933
ID NUMBER FL-0006
                                                     SO'JRCE TYPE CODE
                                                                         1.1

-------
                                             APPENDIX -- DETAILED SOURCE  LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE—-         EXTERNAL COMBUSTION  -  COAL                                       630.00 MW


COMPANY NAME/SITE LOCATION  KANSAS CITY POWER &  LIGHT                                        IATAN, HO
                            IATAN STATION                                                                            PLATTE COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                       DATE OF PERMIT  ISSUANCE—  01/07/77
PEFMIT NO.                                                                                    ESTIMATED DATE  OF  START-UP--    1981
DETERMINATION MADE BY       EPA REGION VII                DANIEL RODRIGUEZ                    (816 )-374-6525
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT       POLLUTANT     EMISSION  LIMITS                                    ... & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
	•	

BOILER, COAL FIRED, PULV.           630.00 MW
                                                          PM         0.1000 LB/MKBTU                                         BACT
                                                                           ESP                                              99.40
                                                          SOZ        1.2000 LB/MM3TU                                         BACT
                                                                           LC'A S WESTERN COAL
                                                          NOX        0.7000 LB/MMBTU                                         NSPS
                                                                           BOILER DESIGN


NOTES 	
THE UNIT IS SUBJECT TO NSPS, SBPART D. THE PSD REGS. ADDRESSED ONLY  PM AND S02.












                                                                                                     INITIAL  REVIEW   POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:  04/01/1953

PAGE G-  48                                          ID NUMBER MO-0004                                    SOURCE TYPE CODE     1.1

-------
                                            APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                        05/22/1934
SOURCE TYPE/SIZE---         EXTERNAL COMBUSTION  - COAL                                       2880.00 MM (TOTAL, 4 UNIT C*


COMPANY NAME/SITE LOCATION  KANSAS POWER & LIGHT CO.                                     ST.  MARY'S, KS
                            JEFFREY ENERGY CENTER                                                               POTTAWATOMIE COUNTY


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE OF PERMIT ISSUANCE—  03/30/78
PERMIT NO.                                                                                     ESTIMATED DATE OF START-UP--   1964
DETERMINATION MADE BY       EPA REGION VII                 DANIEL  RODRIGUEZ                    (8161-374-6525
                             (AGEN'CY)                   (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION LIMITS                                   . . . & BASIS
TO THIS PERMIT                         CAPACITY           EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
_ _ — -___ — ___•___»_.»•___».__•„.•»„ — _________ — •• _ _____________ ___ «.__. __«._««.•. — —._ — ____.._...__..__-__ — — __„_»»__—__•«»• — -,«, — « — — — ™.-—. — ™ — — ._.. — — __ _•— _

COAL FIRED BOILERS, UNITS 3 AST)*    720.00 MW EA
                                                           S02       1.2000 LB/MMBTU                                         BACT
                                                                            WET  LIMESTONE SPRAY TOWERS                       60.00
                                                           PM        0.1000 LB/MMBTU                                         BACT
                                                                            2 COLD SIDE ESP'S PER UNIT                       99.20
                                                           NOX       0.7000 LB/MMBTU                                         NSPS
                                                                            BOILER DESIGN


NOTES 	
THE UNITS ARE SUBJECT TO NSPS, SUBPART D. BACT EMISSION LIMITS FOR NOX AND CO WERE NOT SET BECAUSE THE REGS. ADDRESSED ONLY PM
 AND S02. PLANT NAME: JEFFREY ENERGY CENTER.
UNITS 1 AND 2 WERE NOT SUBJECT TO PSD REVIEW. UNIT  3 STARTUP 1982. UNIT 4 STARTUP 1984.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G-  49
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW STATUS'-  04/01/1S33
ID NUMBER KS-0010
                                                     SOURCE TYPE  CODE
                                                                          1.1

-------
                                             APPENDIX  —  DETAILED  SOURCE LISTING
                                                                                                                          05/22/1984



SOURCE TYPE/SIZE—         EXTERNAL COMBUSTION  -  COAL                                      1300.00 MW
                           ____._.___._._.____„__.-.____.____-___—. — __.-.—._ — — _._. — — — — — — — — — —. — — — — •— — — — — — — — — -- — — — — •— — — -" — — — — — — — — — — — — — — — — •--——— — — — — -- — — — — •— —

COMPANY NAME/SITE LOCATION  KENTUCKY POWER  - CARR'S FAC.                                      ASHAD, KY
                            LEWIS COUNTY  POWER PLANT                                                                    LEWIS COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                         DATE OF PERMIT  ISSUANCE--  04/18/80
PERMIT NO. C-80-42                                                                              ESTIMATED DATE  OF START-UP—   1939
DETERMINATION MADE BY       KENTUCKY DAPC                 BILL DILLS                          (502 >-56<»-3332
                              (AGENCY)                   (AGENCY CONTACT PERSON)                    (P.'iOME)



PROCESSES SUBJECT                     THROUGHPUT       POLLUTANT     EMISSION LIMITS                                    . .. fi BASIS
TO THIS PERMIT                         CAPACITY           EMITTED             CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
_ — — — — — __v _ ___ ___ _._«. — _.«<•»•_ — — • _ — — „.»•.._ —••• — — — .».— — — •.— — — — — _ — ___..__« .._ _...»«_.««__,«___»___«..«« — — — — — .- — — -» — — — .- — ™_ — ___•»• — — *_ — — • — — «•, — — ^«- — —

POWER BOILER                      11943.00  MMBTU/H EA
                                                           S02        0.6000 LB/MM3TU                                          BACT
                                                                             FGD                                               95.00
                                                           PM         0.0300 LB/MMBTU                                          BACT
                                                                             ESP                                               99.81
                                                           NOX        0.6000 LB/KMBTU                                          BACT
                                                                             BOILER DESIGN & OPERATION


NOTES 	
TWO UNIT COAL BURNING POWER PLANT












                                                                                                       INITIAL  REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS  TABLE.                                         r^vlf',' STAn'S:  ?-'./01.'l
-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1954
SOURCE TYPE/SIZE—-
                            EXTERNAL COMBUSTION - COAL
                                                                                           1300.00 MW
COMPANY NAME/SITE LOCATION  KENTUCKY UTILITIES - HANCOCK POWER PLANT
                                                                                        LEXINGTON, KY
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT NO.  C-82-123
DETERMINATION MADE BY       KENTUCKY  DAPC
                             (AGENCY)
                                                          BILL DILLS
                                                       (AGENCY CONTACT PERSON)
                                                                                              DATE OF  PERMIT  ISSUANCE—   04/15/82
                                                                                              ESTIMATED DATE  OF  START-UP—    1990
                                                                                              (502 J-564-33S2
                                                                                                   (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
                                                       POLLUTANT
                                                        EMITTED
                                                                    EMISSION  LIMITS
                                                                           CONTROL EQUIPMENT OR PROCESS  MODIFICATION
                                                                                                                           & BASIS
                                                                                                                           PCT EFF
UNIT SI
                                   6650.00 MMBTU/H
UNIT S2
                                   6650.00  MMBTU/H
                                                          PM        0.0300  LB/MMBTU
                                                                  874.0000  T/YR
                                                                            ESP
                                                          CO     1397.0000  T/YR
                                                          S02       1.2000  LB/MMBTU
                                                                15768.0000  T/YR
                                                                            WET SCRUBBER
                                                          NOX       0.6000  LB/Mk18TU
                                                                17476.0000  T/YR

                                                          PM        0.0300  LB/MMBTU
                                                                  874.0000  T/YR
                                                                            ESP
                                                          CO     1397.0000  T/YR
                                                          S02       1.2000  LB/MMBTU
                                                                15763.0000  T/YR
                                                                            KET SCRUBBER
                                                          NOX       0.6000  LB/K,'iBTU
                                                                17476.0000  T/YR
                                                                                                                             99.80
                                                                                                                             91.50
                                                                                                                             99.80
                                                                                                                             91.80
NOTES
(*) INDICATES DATUM WAS TRUNCATED FOR THIS  TABLE.

PAGE G-  51
                                                                                                      INITIAL REVIEW  POST STAPTUP
                                                                                         REVIEW  STATUS:   04/01/1933
                                                      ID NUC2ER KY-OC27
                                                                                                           SOURCE TYPE CODE    1.1

-------
                                             APPENDIX — DETAILED SOURCE  LISTING                                         05/22/1934

                                             	--------------=-===--======-----=-~=-=--~--===~==~~=	



SOURCE TYPE/SIZE—         EXTERNAL COMBUSTION^COAL	


COMPANY NAME/SITE LOCATION  LOUISVILLE GAS * ELECT.  - TRIMBLE CNTY  *                 ""ES LANDING,  KY              ^^ ^^


                                                                                               DATE  OF PERMIT ISSUANCE--  12/27/78
DETERMINATION IS                                                                               ESTIMATED DATE OF START-UP—   1936
PERMIT HO. C-78-34                                              nil I 5                          <502J-564-3332
DETERMINATION MADE BY                                   (AGScY CONTACT PERSON)                    (PHONE.




PROCESSES SUBJECT                          rTT             i                 ONfSISoUIPMENT OR PROCESS MODIFICATION   '.'.'.
TO  THIS  PERMIT                         CAPACITY    	_.___..


IS-OIRECT HEAT EXCHANGER             ^51.00 MMBTU/H         ^        ^^^ ^^^
                                                                  1275.0000 T/YR
                                                                            ESP
                                                           S02       1.2000 LB/HMBTU
                                                                 10790.0000 T/YR
                                                                            KET SCRUBBER
                                                           NOX       0.7000 LB/MM3TU
                                                                  892^.0000 T/YR



 NOTES 	
 UNIT NUMBER 1
  (*) INDICATES DATUT1 UAS TRUNCATED  FOR THIS

  PAGE  G-   52
ID NUMBER KY-0025
                                                INITIAL jTtVIEU  POST STARTUP
                                   REVIEW STATUS;   0^/01/1^33
                                                     SCL'ICE TYPE CODE    1.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1964



SOURCE TYPE/SIZE—         EXTERNAL COMBUSTION - COAL


COMPANY NAME/SITE LOCATION  LOUISVILLE  GAS  & ELECT. - WISE'S LANDIN*                               , KY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT  ISSUANCE—  03/01/79
PERMIT NO. C-79-53                                                                            ESTIMATED DATE  OF  START-UP—    1938
DETERMINATION MADE BY       KENTUCKY DAPC                  BILL DILLS                          (502 )-564-3382
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHONE )



PROCESSES SUBJECT                    THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... t  BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS MODIFICATION   ... PCT EFF


INDIRECT HEAT EXCHANGER            4851.00  MMBTU/H
                                                          PM        0.1000 LB/MMBTU
                                                                 1275.0000 T/YR
                                                                           ESP                                               99.60
                                                          S02       1.2000 LB/MM3TU
                                                                10790.0000 T/YR
                                                                           WET SCRUBBER                                      90.00
                                                          NOX       0.7000 LB/MMBTU
                                                                 8924.0000 T/YR


NOTES 	
UNIT NUMBER 2.











                                                                                                     INITIAL  REVIEW   POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS  TABLE.                                        REVIEW STATUS:  OV01/19S3

PAGE G-  53                                          ID NUMBER KY-00£<*                                     SOURCE TYPE CODE     1.1

-------
                                             APPENDIX -- DETAILED SOURCE  LISTING
                                                                                                                       05/22/193"+
SOURCE TYPE/SIZE	
                            EXTERNAL COMBUSTION  -  COAL
                                                                                           4735.00 HMBTU/H
COMPANY NAME/SITE LOCATION  LOWER COLORADO RIVER  AUTHORITY
                                                                                                  , TX
                                                                                                                   FAYETTE COUNTY
DETERMINATION IS BACT FOR A NEW SOURCE.
PEPMIT NO. 9231-34
DETERMINATION HADE BY       TEXAS ACB
                             (AGENCY)
   JIM CROCKER
(AGENCY CONTACT PERSON)
DATE OF PERMIT ISSUANCE--  12/22/83
ESTIMATED DATE OF START-UP--
(512)-451-5711
    (FHCNE)
PROCESSES SUBJECT
TO THIS PERMIT
BOILER, LIGNITE FIRED










COAL HANDLING, CONVEYING SYS.


COAL HANDLING, STORAGE



ASH HANDLING


THROUGHPUT POLLUTANT
CAPACITY EMITTED
4735.00 MMBTU/H
H2S*
PM

HG
VGC
NOX

S02

CO
1200.00 T/H
FM

1800.00 T/H
PM


300.00 T/H
PM

EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

954.7000 T/YR
622.0000 T/YR
ESP
0.1300 T/YR
163.2000 T/YR
12350.2000 T/YR
BURNER DESIGN
20736.9000 T/YR
LIMESTONE SCRUBBER
2627.7000 T/YR

53.8000 T/YR
COVERS * UETTING AGENTS

32.9000 T/YR
BAGHOUSE
WET SFRAY

4.7000 T/YR
BAGHOUSE
... 4 BASIS
... PCT EFF

BACT
B/N
99.96
B.4CT
BACT
B/N

B/N
90.00
BACT

BACT


BACT
99.00


BACT
99.00
                                                                            KET UNLD  MIXERS
PAGE G-  54

-------
(CONTINUED) LOWER COLORADO RIVER  AUTHORITY
PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    • - -  * BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT CR  PROCESS  MODIFICATION  ...  PCT EFF


LIMESTONE HANDLING                  300.00 T/H
                                                          PM        0.7000 T/YR                                              BACT
                                                                           ENCLOSURE


NOTES 	
ALT. EMISSION LIMITS ON BOILER ARE — 0.6  LB/MMBTU NOX, 0.03 LB/MMBTU PM,  1.0 LB/MMBTU  SOZ.
                                                                                                      INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEW STATUS:  05/04/1934
PAGE G-  55                                           ID NUMBER TX-0136                                    SOURCE TYPE CCCE    1.1

-------
                                             APPENDIX  —  DETAILED  SOURCE  LISTING
                                                                                                                        05/22/1984




SOURCE TYPE/SIZE---         EXTERNAL COMBUSTION - COAL                                       517.60 MtlSTU/H


COMPANY NAME/SITE LOCATION  MARQUETTE BOARD OF LT * PUR                                   MARQUETTE, MI 49855
                            SHIRAS GENERATING STA.                                                                MARQUETTE COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE--  04/01/80
PERMIT NO. 65-80                                                                               ESTIMATED DATE OF START-UP—   1932
DETERMINATION MADE BY       MICHIGAN DMR                   DAVID FERRIER                        (517)-3£2-1333
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)

— — — — ~—— — ZZZ — — — — — — — — — — — — — —— — — — — — — — — — — — — — — — — — — — — — — — — — ~ — ~ — — — — — ~~~~~~~~'''''~~~~~™~~~"~"~""*~~~"	.- — — — — — — — — — — — — — —• — — — — — — •- — — — •••— — — — — — — — — — — — — —• — — — ~~

PROCESSES SUBJECT                     THROUSHPUT        POLLUTANT    EMISSION LIMITS                                   ... & BASIS
TO THIS PEPMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... FCT EFF
                                               —  — _ ___________ — — _ — — — — — — — — — — »^ — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —— — — —. — ——.—


BOILER, COAL-FIRED                  517.60 MMBTU/H
                                                           PM        0.0300 LB/MMBTU
                                                                            BAGHOUSE                                         99.90
                                                           S02       0.4000 LB/Mt-'BTU
                                                                            SPRAY LIME FGD UNIT                              70.00
                                                                            LOU SULFUR WESTERN COAL
                                                           NOX       0.5000 LB/Mr3TU
                                                                            LONG. FIRING + EXCESS AIR CON.
COAL & ASH HANDLING & STORAGE
                                                           PM        0.0300 GR/DSCF
                                                                            BAG FILTER CONTROL                               99.90
                                                                            ENCLOSURES, CUST SUPPRESSANTS



NOTES 	








                                                                                                      INITIAL REVIEU  POST STARTUP
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:  04/01/1933	°3/13/193*_

PAGE'G-""^                                           ID NUMBER Mi-ooi4                                    SC-JRCE TYPE CCOE    1.1

-------
                                            APPENDIX  — DETAILED SOURCE  LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE—         EXTERNAL COMBUSTION  -  COAL                                     500000.00 LB/H


COMPANY NAME/SITE LOCATION  MICHIGAN SOUTH CENTRAL POWER  AGENCY                          LITCHFIELD, MI
                                                                                                                  HILLSDALE COUNTY
                           __________....___._ — — —.. — — •_• — — — — -. — — — — — — — — —. — — — — — — — — — —••- — — — — — — — — — ..••..•. — -• — — — —•—. — — — — — — -» — — — — — — » — — — — — — — — — — ~ — — •" — — — "~

DETERMINATION IS BACT FOR A NEW SOURCE.                                                         DATE OF PERMIT ISSUANCE—  05/16/30
PERMIT HO. 607-78                                                                              ESTIMATED DATE OF START-UP—   1982
DETERMINATION MADE BY       MICHIGAN DNR                  GREGORY EDWARDS                      (517)-322-1333
                             (AGENCY)                   (AGENCY CONTACT  PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION LIMITS                                    ... & BASIS
TO THIS PERMIT                         CAPACITY           EMITTED             CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF
	.	

COAL-FIRED BOILER                500000.00 LB/H
                                                           PM         0.0300 LB/MMBTU
                                                                            ESP                                              99.70
                                                           S02                                                                NSPS
                                                                            LIMESTONE SPRAY SCRUB                            90.00
                                                           NOX        0.6000 LB/MMBTU
                                                                            CONTRL EXCESS & OVERFIRE AIR


NOTES 	













                                                                                                       INITIAL REVIEW  POST STARTUP

(*) INDICATES DATUM W4S  TRUNCATED FOR THIS TABLE.                                          REVIE^.ST^!:__?^^^!"__..°-.^^!---

      -~~57"                             ID NUMBER MI-0001                                     SOURCE  TYPE CCDE     1.1

-------
                                             APPENDIX -- DETAILED SOURCE LISTING                                         05/22/1984

         _	r-r — = -~-- = - = = ~-~~~-- = --* = - = = ----- = ~ = ~ = = -~- = = ~~~---- = = ~~ = ~~~~ = ~~ = ~ = ~~ = ~~~'~=:~~	



SOURCE TYPE/SIZE—         EXTERNAL COMBUSTION - COAL                          	!!°l°!_'j"	


COMPANY NAME/SITE LOCATION  MINN. POWER & LIGHT CO., CLAY-BOSWELL                     	C°"^S^!l_"!!			


DETERMINATION IS BACT FOR A NEW SOURCE.

                .DE BY       EPA REGION V
                             (AGENCY)




                ;T




BOILER, COAL FIRED                   500.00 MM                                LB/MMBTU                                         NSPS

                                                           S02        1.2000  LB/MM3TU                                         NSPS



NOTES  	



















                                                                                                       INITIAL REVIEW  POST  STARTUP

 («) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.  ^         	_--=! = ==I = I= = = = = = = = = = = = = = = = = === = === = = = = = =

 ^^^ = = ^^^ = ^ = = ^ = = ^ = ^^^^ = ^ = ^^^^^^                                    SSUrXE  TYPE  CCDE    1'1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE—-         EXTERNAL COMBUSTION - COAL                                         98.30  MMBTU/H


COMPANY NAME/SITE LOCATION  MORGANTOHN ENERGY RESEARCH CENTER                           MCRGANTOWN,  WV
                            MORGANTOWN ENER3Y RESEARCH CE*                                                        MONCNGALIA COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                         DATE  OF PERMIT ISSUANCE—  09/20/79
PERMIT NO. 78WV08                                                                              ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY       EPA REGION III                 EILEEN GLEN                          (215 )-597-8187
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION  LIMITS                                    ... t BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... FCT EFF
FLUIDIZED BED BOILER
COAL/LIMESTONE DRYER

COAL/LIMESTONE DRYER
COAL/LIMESTONE DRYER
COAL/LIMESTONE UNLOAD

COAL/LIMESTONE CONVEYORS
                                     98.30  MMBTU/H
   52.00 CF/H

13230.00 T COAL
 66CO.OO T LIMESTONE
20000.00 T COAL LIME*

20000.00 T COAL LIME*
PM        5.4000 LB/H
                 CENTRIF. COLL. i, FABRIC FILTER
S02      86.0000 LB/H
NOX      34.0000 LB/H

                 FABRIC FILTER
                 FABRIC FILTER

                 FABRIC FILTER
BACT
99.00
BACT
BACT

99.00
99.90

99.90
NOTES 	
PROJECT CANCELLED
(*) INDICATES D4TUM HAS TRUNCATED FCR THIS TA2LE.

PAGE G-  59
                                                                                                        TTTAL REVIEW  POST STARTUP
                                                                                                         04/01/1933
                    ID NUriSER  WV-0006
                                                                         SC'JKCE TYPE CODE
                                                                                             1.1

-------
                                            APPENDIX -- DETAILED SOURCE LISTING
                                                                                                                       05/22/1984
SOURCE TYPE/SIZE—         EXTERNAL COMBUSTION - COAL


COMPANY NAME/SITE LOCATION  MUSCATINE POWER  & WATER
                                                                                        MUSCATINE , IA
                                                                                                                 MUSCATINE COUNTY
DETERMINATION IS  B/L FOR A MODIFIED  SOURCE.
PEPMIT NO.
DETERMINATION MADE BY       EPA REGION VII
                             (AGENCY)
                                                          DANIEL RODRIGUEZ
                                                       (AGENCY CONTACT PERSON)
DATE OF PERMIT ISSUANCE--  01/24/80
ESTIMATED DATE OF START-UP--
(816)-374-6525
    (PHONE)
PROCESSES SUBJECT THROUGHPUT
TO THIS PERMIT CAPACITY
BOILER, UNIT »9, COAL/OIL/GAS 166.00 MW






COAL HANDLING

ASH HANDLING

POLLUTANT EMISSION LIMITS ... & BASIS
EMITTED CONTROL EQUIPMENT OR PROCESS MODIFICATION ... FCT EFF
PM 0

S02 0
0

NOX 0

PM 0

PM 0

.0300

.4500
.5600

.6000

.0100

.0200

LB/MM3TU
COLDSIDE ESP
LB/MM3TU 30D R AV
LB/MMSTU MAX D AV
WET-LIHESTCNE SCRUBBER
LB/MMBTU
BOILER DESIGN
GR/SCF
BAGHOUSE
GR/SCF
BAGHOUSE
LAER
99.70
LAER

92.00
BACT

LAER
99.99
LAER
99.93
 LAFRSS"ESTABLI^ED BY THE IOWA DEPT. OF ENVIRONMENTAL QUALITY,  CONTACT  -  AFTER  ?/i/83,  THE  IOHA OEPT.  OF  WATER,  AIR,  &  WASTE M
 ANAGEMENT, 515-2S1-8924. UNIT 9 WILL BURN SOUTHERN ILL.  COAL.  S02  &  FM  OFFSETS  WILL  BE  CSTAINED.
 (*)  INDICATES  DATUM WAS TRUNCATED FOR THIS TABLE.
                                                                                                      INITIAL REVIEW   POST  STARTUP
                                                                                         REVIEW STATUS:   04/01/1983
 PAGE  G-   60
                                                      ID NUMBER IA-0001
                                                                                                           SOURCE  TYPE  CODE     1.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING                                        05/22/198*

                         ___-._-.__—,___—. — — — — — — — — — — — — — — — — — — — — ~~~~~~ — ~ —— —————————— — — — — ~ — — — — — — — — — — — — — — — — — — — — — — — — — — — ~~~~~ ~"



SOURCE TYPE/SIZE—         EXTERNAL COMBUSTION - COAL            ^    _   	t!!l°*.!^				


COMPANY NAME/SITE LOCATION  KE  PUBLIC POWER DIST./GENTLEMAN *2                          SUTHERLAND, NE              LINCOLN COUNTY
                            GERALD  GENTLEMAN STATION (UNI*                        _		_

                                                                                              DATE OF PERMIT ISSUANCE--   02/09/77
DETERMINATION IS BACT FOR A NEW SOURCE.                                                        ESTIMATED DATE OF  START-UP—

                   sr       HPA^OH „,               ISSL^S^LoH,                "".'SSS"*

                                  	---- = rr = = = r = = = = = = = = = = = = = = = = = ::: = = = - = := = ~ = :::~=:: = ==~ = = = = = = = = :: = = ~ = ===~~~~"'


                                                                   __


BOILER, STEAM GEN, COAL FIRED       650.00  MW             ^       ^^^  LB/MnBTU                                         BACT
                                                                            LOW S COAL
                                                          PM       0.1000  LB/r^iBTU                                         BACT
                                                                            ESP



NOTES 	














                                                                                                      INITIAL REVIEW   POST STARTUP

 I.) INDICATES DATUM WAS TRUNCATED  FOR THIS TABLE.                               	?!™.!I™:.-^~""«« = « = «««=
                                                                "                                            SOU7CE TYPECCDE     1.1

-------
                                             APPENDIX  — DETAILED  SOURCE  LISTING
                                                                                                                        05/22/1934



SOURCE TYPE/SIZE	         EXTERNAL COMBUSTION -  COAL                                       650.00 MM


COMPANY NAME/SITE LOCATION  NEBRASKA PUBLIC POUER  DIST.                                            > NE
                            COMSTOCK STATION


DETERMINATION IS BACT                                                                          DATE CF PERMIT ISSUANCE—  12/16/80
PERMIT NO.                                                                                     ESTIMATED DATE CF STAPT-UP--
DETERMINATION HADE BY       NEBRASKA DEC                   GENE  ROBINSON                        (402J-471-21S6
                             (AGENCY)                   (AGENCY  CONTACT PERSON)                    ( FHCS'E )



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION LIMITS                                   ... i BASIS
TO THIS PERMIT                         CAPACITY         EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... FCT EFF


BOILER                              650.00 MW
                                                           PM        0.0300 LB/MM8TU
                                                                            FABRIC FILTER                                    99.90
                                                           S02       70.0000 '/. REMOVAL
                                                                     0.3600 LB/F.N3TU 30D AV
                                                                            DRY SCRUBBER                                     70.00
                                                           HOX        0.5000 LB/MMBTU 3CD AV
                                                           CO       50.0000 PPM
COAL HANDLING
                                                           PM       20.0000 7. OPACITY
                                                                            FABRIC FILTER                                    99.90



NOTES 	









                                                                                                      INITIAL REVIEW  POST STARTUP

 <*)  INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                           _      _      !?^'IEW STATUS:  C^°*lt:!'!	

 PAGE~6-~~62                                           ID NUMBER NE-0002                                    SO'JICE TYPE CODE    1.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984




SOURCE TYPE/SIZE—         EXTERNAL  COMBUSTION - COAL                                       560.00 KW  EA
                           _____ ____ — __ ____„__«.— _______ _ ____ — — __ — — — ^— — ___ — .. — — — — —i — — ^ «.—.-, — •»•_•_ — _— «,™-™ — »^— — -. — — .• — «™ — —«lB~™ — ~»— —»•- — — — — — W.—— — —


COMPANY NAME/SITE LOCATION  NEVADA POWER CO.                                                       > NV
                            25 MILES  NE OF  LAS VEGAS
                           ___. __ _ — • — — — — -,™.™ —— — — — — — ,. — — — .» — — — — —. — — .-•— — — — — — — — — __••. — — .. — — ———————• »» — — — — — — — — ^^™.» — i— — _ — -, — ______  _ _


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF  PERMIT  ISSUANCE--  04/13/81
PE9MIT NO. NV-77-01                                                                           ESTIMATED DATE  OF START-UP—   1990
DETERMINATION MADE BY       EPA REGION IX                  LARRY BOWERMAN                      (415)-974-8213
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHONE)




PROCESSES SUBJECT                    THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ••• * BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ... PCT EFF
BOILERS, 4 EA
                                    560.00 MW
                                                           CO
                                                           NOX
                                                           S02
                                                           PM
                                                           VOC
                                                           PB
                                                           BE

                                                           HG
 320.0000 LB/H
  50.0000 PPM AT 20X EXCESS AIR
          PROPER BOILER DESIGN
          EXCESS AIR HONITORINS
2498.0000 LB/H
   0.4400 LB/MK3TU
          PROPER BOILER DESIGN W/ COMBUSTION AND  LOW NOX*
 566.0000 LB/H
   0.1000 LB/KMBTU
          ONE (1) WET LIME SCRUBBER
          TWO (2) STANDBY MODULES TO IMPROVE SYSTEM RELI*
   0.0150 LB/KM3TU
  10.0000 y. OPACITY
          BAGHOUSE, UNLESS ESP DESIGN APPROVED

          PROPER BOILER DESIGN
          COMBUSTION MONITORS

          NONE
          SAME AS LEAD
          NONE
BACT



BACT


BACT

95.00

BACT

99.76



BACT
 PAGE G-  63

-------
                                                                           FM AND SOS CONTROLS EQUIPMENT
                                                                           MONITOR HG CONTENT IN COAL
                                                          F         9.0000 LB/H
                                                                           SAME AS MERCURY
                                                          H2S*     13.0000 LB/H
                                                                           SAME AS MERCURY W/0 COAL MONITORING
PAGE G-

-------
(CONTINUED) NEVADA POWER CO.
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
$ BASIS
PCT EFF
COAL FIRED BOILERS,  4
ACTIVE COAL STORAGE SILOS
COAL DEWATERING PLANT
                                  31250.00 T/D
INACTIVE COAL STORAGE PILE

LIME CONVEYING, TRANSFER, STORA*
                     PM



                     PM


                     CO


                     NOX


                     SOS


                     BE

                     HG

                     F


                     H2S*
            11.4000 T/YR
                    VENTURIES TO WET SCRUBBER OR BAGHOUSE
                    ENCLOSURE AND UETTINS TRANSFER POINTS

                    TRACE
                    BAGHOUSE ON SILO VENTS
                                                                                                                            99.00
                                                                                                                            95.00
            26.0000 LB/H
            50.0000 PPM
                    SAME AS FOR BOILERS
           304.0000 LB/H
             0.4400 LB/MKSTU
                    SAME AS FOR BOILERS
            46.0000 LB/H
             0.1100 LB/MMBTU
                    SAME AS FOR BOILERS
                    NONE
                    SAME AS FOR BOILERS
                    NONE
                    SAME AS FOR BOILERS
             1.0000 LB/H
             e.oooo LB/H
                    SAME AS FOR BOILERS
             1.0000 LB/H
             2.0000 LB/H
                    SAME AS FOR BOILERS

                    COMPACTION & CHEMICAL STABILIZATION W/BINDING *   90.00

                    BAGHOUSES ON LIME SILO AND SLAKER VENTS.
                    PNEUMATIC UHLOADIN3, ENCLOSED CONVEYORS
PAGE G-  65

-------
(CONTINUED) NEVADA POWER CO.
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT    EMISSION LIMITS                                   ... 4 BASIS
 EMITTED            CONTROL EQUIPMENT OS PROCESS MODIFICATION  ... PCT EFF
ASH HANDLING,STOR.  £ DISPOSAL
PLANT ACCESS t HAUL ROADS
FUEL OIL STORAGE
                                      3.10 MMGAL
                                                          FUG*
                                                          VOC
                                                                           SILO VENTED TO BAGHCUSE.
                                                                           FLY ASH  PNEUMATICALLY CONVEYED  TO  SILO.
                                                                           MOST  ROADS  PAVED AND  20 MPH  SPEED  LIMIT
                                                                            FIXED OR  FLOATING ROOT
NOTES 	
(250) LB/HR LIMITS APPLY TO ANY CONSECUTIVE E4-HOUR  PERIOD, ALL OTHER ARE  FORCONSECUTIVE  30-DAY  PERIOD  AS  DETERMINED  BY  CONTIN
UCUS MONITORING SYS. OPACIT Y LIMIT (6 MINUTE  AVERAGE) CANNOT BE  EXCEEDED
EXCEPT FOR ONE 6-MINUTE PERIOD PER HOUR OF NOT KCRE  THAN  15X OPACITY AS DETERMINED  BY  METHOD  9 09 THE OPACITY  MONITORING SYS.
BACT FOR PM REPRESENTS BACT FOR LEAD. TRACE EQUALS  LESS THAN 0.1  T/YR.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G-  66
                                                                                                      INITIAL  REVIEW  POST STARTUP
                                                                                         REVIEW STATUS:   04/01/1963
                ID NUMBER NV-0001
                                                                     SOURCE TYPE CODE
                                                                                         1.1

-------
                                             APPENDIX ~  DETAILED  SOURCE LISTING
                                                                                                                        05/23/1984



SOURCE TYPE/SIZE—         EXTERNAL COMBUSTION - COAL                                      1080.00 MW


COMPANY NAME/SITE LOCATION  HEW ENGLAND POWER CO., BRAYTON POINT ST*                      SOMERSET, MA


DETERMINATION IS RACT FOR A MODIFIED SOURCE.                                                    DATE OF PERMIT ISSUANCE—  11/01/80
PERMIT NO. APFR. LTR 10-01-80                                                                  ESTIMATED DATE OF START-UP—   1930
DETERMINATION MADE BY       MASSACHUSETTS DEQE - AIR        VAUGHAN STEEVES                     t617)-727-1440
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHOh)E)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION LIMITS                                    ...& BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF
- — —	~ "* — ~	— — — —	_ __________________	......	_	„_..__„.,._	.. ___-._„__..	-. — __ — — __	_	«.__..______.._..	_________	__________________

COAL COMBUSTION                   10625.00 MM3TU/H
                                                           S          1.2100 LB/MMBTU MONTHLY AV                              RACT
                                                                     2.3100 LB/MMBTU DAILY AV
                                                           PM         0.0600 LB/MMBTU                                         RACT
                                                                            ESP                                              99.30
                                                           NOX


NOTES -		
PM TESTED AT 0.03* LB/MMBTU, 0.016 LB/MMBTU,  & 0.010  LB/MMBTU  FOR  UNITS 1-3, RESPECTIVELY. THREE UNITS COMBINED - 250 MW, 25
0 MW, 4 580 MW. VOLUNTARY COAL CONVERSION.













                                                                                                      INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEW STATUS:  04/01/1933

PAGE G-  67                                           ID  NUMBER MA-0006                                    SOURCE TYPE CODE    1:1

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/22/1984
SOURCE TYPE/SIZE —
                            EXTERNAL COMBUSTION  - COAL
                                                                                           7934.00 MMBTU/H
COMPANY NAME/SITE LOCATION  NORTHERN INDIANA  PUBLIC SERVICE CO.
                                                                                       WHEATFIELD, IN
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT NO. EPA-5-A-80-18
DETERMINATION MADE BY       EPA REGION V
                             (AGEKCY)
     BONIFACE THAYIL
  (AGENCY CONTACT PERSON)
DATE OF PERMIT ISSUANCE—  03/31/80
ESTIMATED DATE OF START-UP—
(312)-8S6-6054
    (FHCNE)
PROCESSES SUBJECT THROUGHPUT
TO THIS PERMIT CAPACITY
BOILERS, COAL-FIRED, 2 EA 3967.00 MMBTU/H





FUGITIVE EMISSIONS, CRUSHER HOU*

POLLUTANT
EMITTED

PM

S02

NOX

PM
EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

0.0300 LB/MMBTU
ESP
0.6200 LB/HMBTU
SCRUBBER
0.6000 LB/MMSTU


... 4 BASIS
... PCT EFF


99.73

90.00



FUGITIVE EMISSIONS, CONVEYORS
FUGITIVE EMISSIONS, FLYASH 8 HA*
                                                          PM
                                                          PM
                                                                           BAGHOUSE
                                                                           ENCLOSED COAL CONVEYORS
                                                                           BAGHOUSE
                                                                           WETTED COAL
NOTES 	
TWO BOILERS UNDER PERMIT. TRUCKS UTILIZIED FOR ASH  DISPOSAL SHALL BE COVERED.
                                                                                                                            99.00
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G-  68
                                                                                                     INITIAL REVIEW  POST STARTUP
                                                                                        REVIEW STATUS:  0'V01/19S3
ID NUMBER IN-0003
                                                     SOURCE TYPE CODE    1.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/22/1984
SOUPCE TYPE/SIZE---
EXTERNAL COMBUSTION - COAL
                                                                                           1600.00 MM
COMPANY NAME/SITE LOCATION  NORTHERN STATE POWER CO., SHERBURNE STA
                                                                                           BECKER, MN
                                                                                                                 SHERBURNE COUNTY
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT NO. EPA-5-77-A-2
DETERMINATION MADE BY       EPA REGION V
                             (AGENCY)
                              BONIFACE THAYIL
                            (AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE--  04/25/77
                                       ESTIMATED DATE OF START-UP--
                                       (312)-8a&-6C54
                                           (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
          THROUGHPUT
           CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
t BASIS
PCT EFF
BOILER, COAL FIRED, 2 EA
                                    800.00 MM
                                                          PM
                                                          S02
                                         0.1000  LB/MMBTU
                                         1.2000  LB/MM3TU
                                                                     NSPS
                                                                     NSPS
NOTES
(*> INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G-  69
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW STATUS:   04/01/1933
                          ID NUMBER MN-0007
                                                                               SOURCE TYPE CODE
                                                                                                   1.1

-------
*d* n
CO II
O- 1
r-l n
X n
c\j n
CJ II
X II
to n
O II
u
n
n
n
n
n
n
n
M
n
i
i
i
i
i
i
i
i
u
u
n
M
n
u
n
u
n
n
n
u
n
i
n
u
n
u
i
n
i
CD II
M II
h- 1
01 1
M 1
_J 1
1
UJ 1
O 1
g !
O I
V) 1
I
O 1
UJ 1
-J 1
M 1
< II
t- M
UJ II
o n
11
1 II
t II
II
X, H

e n
LU II
Q. II
Q. II
< II
1
II
II
H
II
II
II
It
II
II
U
II
}
II
1
H
11
II
II
I
II
II
II
II
II
II
II
II
II
1
I
I
1
t
1
1
1
1
1

I
1
1




































































_J
«t
O
u
1

"Z.
0

h-
s


o
u


<(
z
CK
UJ
)»
^
UJ









1
1
1
UJ
N
M
CO
X
UJ
CL
^.
r-

UJ
U
g
O
01
^.
L-,
[^

O
u

UJ
u

UJ
1

_J













§

V.
£
M
O
CL
^
h-
3
o
01




















r-
u
UJ
1
o
CK
Q.

O
E
UJ
a

UJ
§


h-t
i;

a."
UJ
H~

3

.j
 CK n
Z < n

D 01 M
Ol II
01 U- II
MO II
II
r- UJ 11 n
M r- U~i II
E < iH II
CK CJ Ul ~ II
UJ 1 UJ II
0. C r-1 7. n
uj in o n
U. |~ Kl X II
O < 1 CL II
r. — — n
UJ M - II
< O II
CK z n
U- UJ II
ID II
< 11
•» 11
II
II
II
II
II
II
II
II
II
II
II
II
M
II
II
II
II
II
1. II

3 >- n
O (J II
z: z u
01 UJ II
r- to H
a < n
O — II
CL II
n
n
u
n
u
u
n
V II
03 II
II
UJ II
r^ D n
01 0 < II
M r-l H II
1 II
z r> z n
O 0 O II

i- • i- ii
•< O < II
z z z n
MM II
r i- i: n
CK M u; II
UJ n UJ II
1- CK H- II
UJ UJ UJ II
CD CL 0 II
01 U.
M U.
01 UJ

03 h-
U
•a CL

, ,
« .
« ,

Z
o
M

<{
(J

U.
M
Q
O
sr

01
01
UJ
o
o

a
CK
o

t-
z
UJ

a.
M
^3
cr
UJ
01
M O

l-l k-
-1 7.
O
Z U

M
Ol
01
M
JZ
UJ



So
•< UJ
>— *—
3 !-
_J M
i y
O UJ
P.







^

a. h-
X M
13 (J
Z) <
O 0.
CK <

pZ





















V-
o
UJ
-> t-
CO M
3 n
01 CK
UJ
01 CL
UJ
01 01
01 M
UJ I
O h-
O
a o
U. (-
c- o o
oiO'Oi 010-01 uic>oi
CL • a. a. • a. n. • a.

Z^Z ZCr^Z 2C^Z
_J
<^
O
(J

01
01
UJ
u
o
CK


u.
0

1-
01
o
i:

z
M

O
1-
UJ

01
y.
z
^
t- CK
UJ
CK CK or - u.
uJ uj uj 01 01
h- t- I- uj z
_1 -1 _J CL <
M>- M>- M>- MCK
U.H- U.K U.H Q.H-
UOU OOU UOO >-U.

O CK CL D CK O- D D" D-
XGJO X(DO XCJO OX
CK CL > CL > CKO
U. CL
0 CK

-J O BJ
-j CK i:
< u- D
*jr
CK CK
UJ tH >-
M < M
3 3 3 CK CK a:
1— t— 1— uj uj uj
CO CQ tij ^» U- ^
y y~ y i (/j
XI 2Z 3Z 3 2^ O
O. < 01
000 CK -J
CO CO CO O 1- <
. t-
W CJ (VI UJ •
a 1- a
Ul  OJ -J
M -J
UJ • M
U CK DC
UJ UJ
CK K Ul
< Ul
-J 3 3
< O
0 I Zi
OHO
M '!
IX 3 CO
O
u. a j;
UJ O
t- X C£
01 CL M u.
r-l Cg K* UJ UJ E
O O O h- LJ CK
O O O O X Ol M
Q. CL CL Z UJ M •<

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/22/1984



SOURCE TYPE/SIZE—         EXTERNAL COMBUSTION - COAL                                       635.00 MW


COMPANY NAME/SITE LOCATION  NY STATE ELECT, t GAS - CYUGA STATION                         SOMERSET, NY
                                                                                                                   NIAGARA COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—  06/29/81
PERMIT NO.                                                                                    ESTIMATED DATE OF START-UP—    1936
DETERMINATION MADE BY       EPA REGION  II                  BARRY TORNICK                       (212)-264-9579
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                    THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... t BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF
MAIN BOILER
                                   1750.00 MMBTU/H
AUXILIARY BOILERS,  2
                                    195.00 MMBTU/H
PM

S02


NOX

CO

F

PB

HG

BE


S02

NOX
0.0300 LB/MMBTU
       ESP
0.7000 LB/MMBTU
0.6000 LB/MM3TU
       FGD & 5<3.6X BY WT.
0.6000 LB/MKBTU
       GOOD DESIGN ft COMBST PRACT.

       GOOD COMBST PRACT.

       FGD SYSTEM

       ESP/FGD

       ESP/FGD

       ESP/FGD


       USE OF #2 FUEL OIL
BACT

BACT

90.00
BACT

BACT

BACT

BACT

BACT

BACT


BACT

BACT
PAGE G-  71

-------
                                                                           USE  OF  82  FUEL OIL
PAGE 6-  7Z

-------
(CONTINUED) NY STATE ELECT.  * GAS -  CYUGA STATION
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT    EMISSION LIMITS
 EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION
...  t  BASIS
. ..  PCT  EFF
COAL HANDLING
LIMESTONE HANDLING
FLY ASH HANDLING
                                 200000.00 T/YR
                                                          PM
                                                          Ptl
                                                          PM
                                                                           FABRIC FILTER
                                                                           H20 SPRAY « ENCLOSED SYS.
                                                                           FABRIC FILTER
                                                                           H20 SPRAY & ENCLOSED SYS.
                                                                           FABRIC FILTER
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
NOTES
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G-  73
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW STATUS;   04/01/1933
                                                      ID NUMBER NY-0003
                                                                     SOfSCE TYPE CODE    1.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE—-         EXTERNAL COMBUSTION - COAL                                       550.00 MW
                           	,	.	

COMPANY NAME/SITE LOCATION  OKLAHOMA GAS &  ELECT. CO.                                      BEDROCK, OK
                                                                                                                     NOBLE COUNTY


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF  PERMIT  ISSUANCE--  10/05/81
PERMIT NO. (REGION FILE NO.) PSD-CK-218                                                       ESTIMATED DATE  OF START-UP—    1986
DETERMINATION MADE BY       EPA REGION VI                 JOHN BUNYAK                         (214J-767-1594
                             (AGENCY)                  (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                    . .. «  BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF
GEN. UNITS, COAL-FIRED, Z EA
                                   5250.00  MMBTU/H
TUNNELS, COAL RECLAM.,  2 EA
COAL CRUSHER TOWER
BIN TOWERS, COAL SURGE, Z EA
S02       0.4600 LB/MMBTU
                 FLUE GAS DESULFURIZATION
NOX       0.5000 LB/Mf!BTU
                 EXCESS AIR
CO        0.0640 LB/KM3TU
                 COM. CONTROLS & PROPER OPER.
PM        0.0300 LB/MM3TU
                 ESP OR BAGHOUSE

PM        2.8000 LB/H
                 DUST COLLECTOR

PM        3.4000 LB/H
                 DUST COLLECTOR

PM        3.9000 LB/H
                 DUST COLLECTOR
NSPS
70.00
NSPS

BACT

NSPS
99.60

BACT
93.00

BACT
98.00

BACT
98.00
PAGE G-  74

-------
(CONTINUED) OKLAHOMA GAS & ELECT.  CO.
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
,..  * BASIS
, ..  PCT  EFF
COAL SILOS, 2 EA
COAL STORAGE PILES
                                     80.00  LB/ACRE-H
                                                          PM
                                                          PM
                               3.7000 LB/H
                                      DUST COLLECTOR

                               5.8000 LB/ACRE
                                      CHEMICAL 4 WATER STABILIZERS
                                                                     BACT
                                                                     98.00

                                                                     BACT
NOTES 	
OKLAHOMA GAS » ELECTRIC COMPANY,  UNIT *3.
(*) INDICATES DATUM WAS TRUNCATED FOR  THIS  TABLE.

PAGE G-  75
                                                                INITIAL REVIEW  POST STARTUP
                                                   REVIEW STATUS-1  0'»/01/1983
                                                      ID NUMBER GK-OC03
                                                                                                           SOU3CE TYPE CODE    1.1

-------
                                             APPENDIX  —  DETAILED  SOURCE  LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE-—         EXTERNAL COMBUSTION - COAL                                       550.00 MW


COMPANY NAME/SITE LOCATION  OKLAHOMA GAS & ELECT. CO.                                      MUSKOGEE, OK


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE OF PERMIT ISSUANCE—  03/30/78
PERMIT NO. PSO-OK-57                                                                           ESTIMATED  DATE OF START-UP—
DETERMINATION MADE BY       EPA REGION VI                  JOHN  BUNYAK                          (314)-767-1594
                             (AGENCY)                  (AGENCY  CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROU3HPUT       POLLUTANT     EMISSION  LIMITS                                    . . .  * BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS  MODIFICATION  ...  PCT EFF
______«._ — __»„.___»_____ — __•__ — ____—._____ —~ —___ — — — — — — — — — — — —. — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —^ —•" — — — — •«•• — — —••^• — — — —

COAL FIRED BOILER                   550.00 MW
                                                           S02        1.2000  LB/MMBTU
                                                                  6180.0000  LB/H
                                                                            LOU  S WESTERN  COAL
                                                           PM         0.1000  LB/MHBTU
                                                                  212.0000  LB/H


NOTES 	















                                                                                                      INITIAL REVIEW  POST  STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                       REVIEW STATUS:   04/01/1983

PAGE G-  76                                           ID  NUMBER  OK-0002                                     SOURCE TYPE CODE    1.1

-------
                                            APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                        05/22/1934



SOURCE TYPE/SIZE---         EXTERNAL COMBUSTION  - COAL                                        500.00 MW


COMPANY NAME/SITE LOCATION  PACIFIC POWER  *  LIGHT                                    POINT OF  ROCKS, WY


DETERHINATION IS BACT FOR A NEW SOURCE.                                                         DATE OF PERMIT ISSUANCE—  12/01/75
PERMIT NO. CT-23                                                                               ESTIMATED DATE OF START-UP—   1979
DETERMINATION MADE BY       WYOMING AQD                     LEE SRIBOVICZ                        (307 )-332-314
-------
                                             APPENDIX  — DETAILED SOURCE  LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE—-         EXTERNAL COMBUSTION -  COAL                                         37.00  MW


COMPANY NAME/SITE LOCATION  PANORAMA ENERCORP,  INC                                   KETTLE  FALLS,  WA


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE  OF  PERMIT  ISSUANCE--   09/22/81
PERMIT NO. (REGION FILE NO.) PSD-X81-15                                                        ESTIMATED DATE  OF  START-UP--
DETERMINATION MADE BY       EPA REGION X                  PAUL BOYS                           (206 )-4<+2-1193
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                    ... & BASIS
TO THIS PERMIT                        CAPACITY         EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT  EFF


BOILER                               37.00 MW
                                                          PM        0.0070 GR/DSCF 127. C02
                                                                           ESP                                              99.00
                                                          CO      107.3000 LB/H                                             BACT
                                                          VOC      36.5000 LB/H
                                                          NOX       0.1700 LB/ttMBTU                                         BACT


NOTES 	
GENERAL DESIGN CONTRIBUTES TO REDUCTION  OF ALL  POLLUTANTS AND INCLUDES 1) INCREASED BOILER HEIGHT FOR BETTER EFFICIENCY,  2) 0V
ERFIRE /NO U>;DERFIRE AIR, 3) FEEDWATER HEATERS  TO  INCREASE EFFICIENCY.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G-  78
                                                                                                     INITIAL REVIEW  POST STARTUP
                                                                                        REVIEW STATUS:  04/01/19S3
ID NUMBER WA-0001
                                                     SO'JRCE TYPE CODE
                                                                         1.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE—-         EXTERNAL  COMBUSTION - COAL                                       625.00 MW ONE
                           ________ _— __„______»_______ _— — ______„___„________»__ — W_«__ — —»_ — — «————— — — — — —.— ———— — — — — — — ——•*••—— — — -• — — — -• — — — !^ —

COMPANY NAME/SITE LOCATION  PENNSYLVANIA ELECT. CO.                                      LAKE CITY, PA
                            COHO-1                                                                                     ERIE COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE— 08/18/81
PERMIT HO. 78PA13                                                                             ESTIMATED DATE OF START-UP—   1989
DETERMINATION MADE BY       EPA REGION  III                 DAVID ARNOLD                        (215)-597-7936
                             (AGENCY)                  (AGENCY CONTACT PERSON)                    ( PHONE)



PROCESSES SUBJECT                    THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    . .. t BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF


UTILITY BOILER,  COAL FIRED        6280.00 MMBTU/H
                                                          PM        0.0300 LB/MMBTU                                         NSPS
                                                                           ESP                                              99.70
                                                          S02       0.6260 LB/MMBTU                                         BACT
                                                                           LIME SCRUBBING-??*                               99.00
                                                          NOX       0.6000 LB/MMBTU                                         NSFS
                                                          CO        0.0400 LB/MMBTU                                         NSFS
COAL AND ASH HANDLING
                                                          PM                                                                BACT
                                                                           WET SUPPRESSION AND DUST COLLECTORS


NOTES 	
UP TO 40X SULFUR TO BE REMOVED BY COAL  CLEANING PRIOR TO REACHING BOILER.









                                                                                                     INITIAL REVIEW POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:   04/01/1983

PAGE G-  79                                          ID NUMBER PA-0004                                    SCL"5CE  TYPE  CODE     1.1

-------
                                             APPENDIX -- DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE—         EXTERNAL COMBUSTION  - COAL                                      2471.00 HM3TU/H


COMPANY NAME/SITE LOCATION  PLAINS ELECT.  GEN &  TRANS                                      PREWITT, KM
                                                                                                                  MCKINLEY COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT  ISSUANCE—  05/27/81
PERMIT NO. (REGION, FILE NO.) PSQ-NM-82                                                        ESTIMATED DATE  OF START-UP—    1983
DETERMINATION MADE BY       EPA REGION VI                  JOHN BUNYAK                         (214 )-767-1594
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHCNE)

r = = = = = = = r = = = r = r = = = = = = = = = = = : = r = = = r = = = = = = : = = :r = = = = = = = - = = = = = = = = = = = = = = = = = r = = = = = = = = ==r = = = = r = = = = = = = r = = = = = = = = = = r = r = r = = = r = = r = r = = = r = = = = = = r =

PROCESSES SUBJECT                     THROUGHPUT       POLLUTANT    EMISSION LIMITS                                   ... t BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT CR PROCESS MODIFICATION  ... PCT EFF
STEAM GENERATOR, COAL-FIRED
                                   2471.00 MMBTU/H
COAL HANDLING

STOCKPILING AND STORAGE

LIMESTONE HANDLING

FUGITIVE EMISSIONS
     PM

     S02

     CO

     NOX

     F

     PM

     PM

     PM

     PM
                                                                     0.0300  LB/T.MBTU
                                                                            BAGHOUSE
                                                                     0.2000  LB/MM3TU
                                                                            FLUE GAS DESULFURIZATICN
                                                                     0.0630  LB/MKBTU
                                                                            FIRE BOX DESIGN  4 COM. CONTROL
                                                                     0.4500  LB/MMBTU
                                                                            FIRE BOX DESIGN  t COM. CONTROL
                                                                     0.0010  LB/MMBTU
NSPS
99.90
BACT
90.00
BACT

BACT

BACT
NOTES
(*> INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G-  80
                                                                                                      INITIAL REVIEW   POST  STARTUP
                                                                                        REVIEW STATUS;   04/01/1933
ID NUMBER NM-0002
                                                     SOU"CE TYPE CODE
                                                                         1.1

-------
                                            APPENDIX -- DETAILED SOURCE LISTING
                                                                                                                        05/23/1984
SOURCE TYPE/SIZE---
                            EXTERNAL COMBUSTION - COAL
                                                                                            250.00 MW
COMPANY NAME/SITE LOCATION  PLATTE RIVER  PWR-RAKHIDE
                                                                                NEAR FORT COLLINS, CO
                                                                                                                    LARIMER COUNTY
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT NO.
DETERMINATION MADE BY       EPA REGION VIII
                             (AGENCY)
                       JOHN DALE
                    (AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE—  05/22/80
                                       ESTIMATED DATE OF START-UP—
                                       (303)-837-3763
                                           (PHOKE)
PROCESSES SUBJECT
TO THIS PERMIT
  THROUGHPUT
   CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
& BASIS
PCT EFF
BOILER
                                    250.00  MW
COAL CONV


COAL CRUSHING


COAL STORAGE


COAL UNLOAD
870.00 MT/YR
870.00 MT/YR
870.00 MT/YR
                                    870.00  MT/YR
   NOX       0.5000 LB/MMBTU
                    DESIGN
   PM        0.0300 LB/MMBTU
                    BAGHOUSE
   S02       0.1300 LB/MMBTU
                    DRY SCRUBBER

   PM        0.5300 LB/H
                    BAGHOUSE

   PM        0.4000 LB/H
                    BAGHOUSE

   PM       40.4000 LB/H
                    CRUSHING AGENT

   PM        1.0500 LB/H
                    BAGHOUSE
                                                        BACT
                                                        65.00
                                                        BACT
                                                        99.70
                                                        BACT
                                                        80.00

                                                        BACT
                                                        99.70

                                                        BACT
                                                        99.70

                                                        BACT
                                                        80.00

                                                        BACT
                                                        99.70
PAGE G-  81

-------
(CONTINUED) PLATTE RIVER PWR-RAWHIDE
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATIOM
X BASIS
PCT EFF
LIME STORAGE
SILO(ASH)
                                      5.60 MT/YR
                                     57.70  MT/YR
                                                          PM
                                                          PM
                               0.0400 LB/H
                                      BAGHOUSE

                               0.0100 LB/H
                                      BAGHOUSE
                                                                     BACT
                                                                     99.60

                                                                     BACT
                                                                     99.70
NOTES
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G-  83
                ID NUMBER CO-OOia
                                                                INITIAL REVIEW  POST STARTUP
                                                   REVIEW STATUS:  04/01/1983

                                                                     SOURCE TYPE CODE    1.1

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                         05/22/1984



SOURCE TYPE/SIZE—-         EXTERNAL COMBUSTION - COAL                                       350.00 MM
                           „___	«.	«.	_„_..__._.._	»	-.-.__ — -.„-. — -.__. — -._-. — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —	— __ — «._ — — _ — — — — — — -.—

COMPANY NAME/SITE LOCATION  SALT RIVER PROJECT CORONADO STATION UNI*                     ST. JOHNS, AZ
                           -.___ — ___ — ___ —— __ — ____»_ — —~_ — — ~_ —— ~ —— — -. — — — •. — — — *— — — —. — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — "" — — —~ —

DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE—  04/10/78
PERMIT NO. (REGION FILE NO.) AZP76-1                                                           ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY       EPA REGION IX                  JIM HANSON                          (415)-974-8038
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... t BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF
_____«___.>_____ ___._____,._ ___..______.._____ _______ _, ___ __ _____ __ ___ ..__._ •_ _~_ _____ ___ «»__ __.._« __^^.._ — — _ __ — __ — —_ .._____.__ ___~__ ________

STEAM GEN. UNIT                     350.00 MM
                                                           PM        0.0820 LB/MMBTU
                                                                            ESP
                                                           S02       0.8000 LB/MM3TU
                                                                            WET LIMESTONE SCRUBBER                            64.00
                                                           NOX       0.7000 LB/MMBTU                                          NSPS


NOTES 	
COAL CONVEYING SYS WILL BE ENCLOSED AND DUST SUPPRESENT ADDED AT TRANSFER POINTS.














                                                                                                      INITIAL REVIEW   POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:  C4/01/19S3

PAGE G-  83                                           ID NUMBER AZ-0004                                    SOURCE  TYPE C03E    1.1

-------
                                             APPENDIX ~  DETAILED  SOURCE  LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE-—         EXTERNAL COMBUSTION - COAL                                       890.00  MW


COMPANY NAME/SITE LOCATION  SANDOW STEAM ELECT. STATION                                   ROCKDALE,  TX
                                                                                                                      MILAM COUNTY


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE  OF PERMIT ISSUANCE--  09/20/77
PERMIT NO. PSD-TX-28                                                                           ESTIMATED  DATE OF  START-UP--
DETERMINATION MADE BY       EPA REGION VI                 TOM  DIGGS                            <214)-767-1594
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT       POLLUTANT     EMISSION  LIMITS                                    . ..  S. BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT OR  PROCESS  MODIFICATION  ...  PCT EFF


BOILER, LIGNITE FIRED               890.00 MW
                                                          S02        1.2000  LB/MMBTU
                                                                  6827.0000  LB/H
                                                                            FGD                                               70.00
                                                          PM         0.1000  LB/MMBTU
                                                                            ESP                                               99.80


NOTES 	














                                                                                                      INITIAL REVIEW   POST  STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:   O't/01/1933

PA3E G-  84                                           ID  NUMBER TX-0007                                    SCUPCE TYPE  CODE    1.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/198*



SOURCE TYPE/SIZE—-         EXTERNAL COMBUSTION - COAL                                       530.50 MM


COMPANY NAME/SITE LOCATION  SIERRA PACIFIC  POWER CO.                                         VALMY, NV


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF  PERMIT  ISSUANCE—  04/04/78
PERMIT NO. (REGION FILE NO.) NV 77-02                                                         ESTIMATED DATE  OF START-UP--    1933
DETERMINATION MADE BY       EPA REGION IX                 DAVID SOLOMON                       (415)-974-8066
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHON'E)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ...» BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ...  PCT EFF


BOILERS, COAL FIRED, 2              277.00  MM
                                                          S02       1.2000 LB/MMSTU
                                                          NOX       0.7000 LB/MM3TU
                                                          PM        0.10CO LB/MM5TU
                                                                           BAGHOUSE                                          99.75


NOTES 	
EMISSION LIMITS APPLY TO EACH UNIT SEPERATELY. BASIS DETERMINED BY NAPS AND PSD CLASS II  INCREMENT CONSIDERATIONS.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G-  85
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS;  04/01/1933    02/13/1934
                                                      ID NUMBER NV-0002
                                                                                                           SCU2CE  TYPE CODE    1.1

-------
                                             APPENDIX  -- DETAILED SOURCE  LISTING
                                                                                                                        05/32/1984



SOURCE TYPE/SIZE—         EXTERNAL COMBUSTION -  COAL                                      235.00 MW


COMPANY NAME/SITE LOCATION  SIKESTON BOARD OF MUNICIPAL UTILITIES                         SIKESTON, MO
                                                                                                                     SCOTT COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—  07/14/77
PERMIT NO.                                                                                    ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY       EPA REGION VII                CHARLES WHITMORE                    (616 )-374-6525
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT       POLLUTANT    EMISSION LIMITS                                    ... S BASIS
TO THIS PERMIT                         CAPACITY         EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF


BOILER, STEAM GEN, COAL FIRED       235.00 MW
                                                          S02       1.2000 LB/MMBTU                                         BACT
                                                                           WET LIMESTONE SCRUBBER
                                                          PM        0.1000 LB/MM3TU                                         BACT
                                                                           ESP


NOTES 	















                                                                                                     INITIAL REVIEW  POST STARTUP
(»> INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:  04/01/1933

PAGE G-  66                                           ID NUMBER MO-0003                                    SOURCE TYPE CODE    1.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE—         EXTERNAL COMBUSTION - COAL                                       567.00 MM, 2 EA


COMPANY NAME/SITE LOCATION  SOUTHWESTERN  PUBLIC SERVICE                                      SUOAN, TX
                                                                                                                       LAMB  COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF  PERMIT  ISSUANCE—  03/30/78
PERMIT NO. (REGION FILE NO.) PSO-TX-50                                                         ESTIMATED DATE  OF  START-UP-
DETERMINATION MADE BY       EPA REGION VI                 TOM DIGGS                           (214 )-767-1594
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     ( PHOf^E )



PROCESSES SUBJECT                    THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                    ...  t BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ...  PCT EFF


STEAM TURBINE, COAL-FIRED           567.00  MW
                                                          S02     508.8000 LB/H
                                                                    1.2000 LB/MMBTU
                                                                           LOU SULFUR  FUEL
                                                          PM        0.1000 LB/MM3TU
                                                                           FABRIC FILTER                                     98.60
                                                                           SPRINKLE ROADS WITH WATER OR CHEM.


NOTES 	
TWO UNITS, 567 MW EACH.












                                                                                                     INITIAL  REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS  TABLE.                                        REVIEW STATUS:   04/01/1933

PAGE G-  87                                          ID NUMBER TX-0006                                     SOURCE TYPE CODE    1.1

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                         05/3Z/1984



SOURCE TYPE/SIZE-—         EXTERNAL COMBUSTION - COAL                                       348.00 MW  (GROSS)
                           — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —^«_ — .- — ___ —»___w.— — — — —^—— — » — — — — -.._ — —...—.__..«. — __._.__._.__.«__.•..».»

COMPANY NAME/SITE LOCATION  SUNFLOWER ELECT. COOP., INC. - HAYS, KS.              NEAR HOLCOMB, KA, KS
                            HOLCCMB STATION                                                                           FINNEY COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF  PERMIT ISSUANCE—   05/19/80
PERMIT NO.                                                                                     ESTIMATED DATE OF START-UP--
DETERMINATION MADE BY       EPA REGION VII                 DANIEL RODRIGUEZ                    (816)-374-6525
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT  EFF


BOILER, COAL-FIRED                 3389.00 MMBTU/H
                                                           NOX       0.6000 LB/MMBTU                                         BACT
                                                                            STAGED COMBUST., LEA
                                                           SOZ       0.4800 LB/MM3TU 3CD R AV                                BACT
                                                                            LIME BASED DRY SCRUBBER                          SO.00
                                                                            LIME BASED DRY SCRUBBER
                                                           CO        0.0640 LB/MMBTU 300 R AV                                BACT
                                                           Ptl        0.0300 LB/M,'iBTU                                         BACT
                                                                            FABRIC FILTER


NOTES 	
THE NOX LIMIT TAKES PRIORITY OVER THE CO LIMIT. IF NECESSARY THE CO LIMIT WILL BE ADJUSTED AFTER THE UNIT HAS BEEN PERFORMANCE
 TESTED.  THE UNIT WILL BURN LOU S WYOMING COAL.









                                                                                                      INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEW STATUS:   04/01V933

PAGE G-  88                                           ID NUMBER KS-0001                                    SC'JSCE TYPE CCOE     1.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/22/1984
SOUP.CE TYPE/SIZE—
                            EXTERNAL COMBUSTION - COAL
                                                                                           1440.00 MW
COMPANY NAME/SITE LOCATION  SW ELECT.  POWER
                                                                                           CANTON, TX
                                                                                                                 VAN ZANDT COUNTY
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT NO. (RESIGN FILE NO.) PSO-TX-130
DETERMINATION MADE BY       EPA REGION VI
                             (AGENCY)
   JOHN BUNYAK
(AGENCY CONTACT PERSON)
DATE OF PERMIT ISSUANCE--  02/23/81
ESTIMATED DATE OF START-UP--
(214>-767-1594
    (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
BOILERS, 2 EA








COAL UNLOAD


COAL TRANSFER


COAL STORAGE

THROUGHPUT POLLUTANT
CAPACITY EMITTED
6821.00 HMBTU/H
PM

S02

NOX


CO


PM


PM


PM
EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION
0.0300 LB/MMBTU
ELECTROSTATIC PRECIPITATOR
0.9000 LB/Mr.BTU
WET LIMESTONE FLUE SAS DESULFURIZATION
0.6000 LB/KMBTU
LOW NOX BURNERS
FLUE GAS RECIRCULATION
0.1000 LB/"M3TU
LOW EXCESS AIR

2.4000 LB/H
WET SUPPRESSION

2.4000 LB/H
ENCLOSED

2.4000 LB/H
... 4 BASIS
... PCT EFF
NSPS
99.80
BACT
87.40
NSPS


BACT









                                                                            CHEMICAL STABILIZER
 PAGE  G-   89

-------
(CONTINUED) SW ELECT. POWER
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT    EMISSION LIMITS
 EMITTED            CONTROL EQUIPMENT OH PROCESS MODIFICATION
. . .  &  BASIS
...  PCT EFF
LIMESTONE UNLOAD
LIMESTONE TRANSFER
LIMESTONE STORAGE
                                                           PM
                                                           PM
                                                           PM
                               0.2000 LB/H
                                      WET SUPPRESSION

                               0.6000 LB/H
                                      ENCLOSED

                               0.2000 LB/H
                                      CHEMICAL STABILIZER
NOTES 	
NOX LIMIT FOR BOILERS IS 30 DAY ROLLING AVERAGE.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G-  90
                                                                                                      INITIAL REVIEW   POST  STARTUP
                                                                                        REVIEW STATUS;   04/01/1933
                10  NUMBER  TX-0010
                                                                     SOURCE TYPE COOE    1.1

-------
                                            APPENDIX -- DETAILED SOURCE LISTING
                                                                                                                        05/22/1934



SOURCE TYPE/SIZE—         EXTERNAL COMBUSTION - COAL                                       720.00 MM  EA


COMPANY NAME/SITE LOCATION  SW ELECT.  POWER                                              NABORTION, LA  71156
                            P.O.  BOX 21106                                                                    DESOTO PARISH PARISH


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF  PERMIT ISSUANCE—  09/01/81
PERMIT HO. (REGION FILE NO.) PSO-LA-117                                                       ESTIMATED DATE OF  START-UP--
DETERMINATION HADE BY       EPA REGION VI                 JOHN BUNYAK                         (2141-767-1594
                             (AGENCY)                   {AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                    ...  & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ...  PCT EFF
BOILER, COAL FIRED
BOILER, COAL FIRED
COAL HANDLING
                                    720.00  MW
                                    720.00  MW
S02

NOX

P«

CO


S02

NOX

PM

CO


PM
1.2000 LB/MMBTU
       FGD
0.6000 LB/MM3TU
       LCVJ NOX BURNERS
0.1000 LB/HMBTU
       ESP
0.8000 LB/MMBTU
       EFFICIENT COMBUSTION

0.6000 LB/MMBTU
       FCO
0.6000 LB/MM3TU
       LOW HOX BURNERS
0.0300 LB/Mf.BTU
       ESP
0.8000 LB/MM3TU
       EFFICIENT OPERATION
                                                                           SPRAY APPL. & DUST COLLECT.
                                                                                                                             NSPS
                                                                                                                             76.00
                                                                                                                             NSPS

                                                                                                                             BACT
                                                                                                                             99.80
                                                                                                                             BACT
                                                                                                                             NSPS
                                                                                                                             89.50
                                                                                                                             NSPS

                                                                                                                             BACT
                                                                                                                             99.SO
                                                                                                                             BACT
(*) INDICATES DATUM WAS TRUNCATED FOR THIS  TABLE.

PAGE G-  91
                                           INITIAL REVIEW  POST STARTUP
                              REVIEW STATUS:  04/01/1933
                                                     ID NUMBER LA-0002
                                                                                                           SOURCE  TYPE  CODE
                                                                                                                               1.1

-------
NOTES 	
UNIT 1 UNDER 40CFR PART 60 SUBPART D.  UNIT 2  UNDER 40CFR PART 60 SUBPART DA. FUGITIVE DUST CONTROLLED BY WATER SPRAY DURING CO
NSTRUCTION
                                                                                                     INITIAL REVIEW   POST STARTUP
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:   04/01/1933
PAGE G-  92                                          ID NUMBER  LA-0002                                    SC'JRCE TYPE C03E     1.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/32/1984
SOURCE TYPE/SIZE—         EXTERNAL COMBUSTION - COAt                                       720.00 MM,  2  EA


COMPANY NAME/SITE LOCATION  SH ELECT.  POWER                                                 DALLAS, TX 75250
                            2700 ONE MAIN  PL.


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT  ISSUANCE-
PERMIT HO.                                                                                    ESTIMATED DATE  OF  START-UP-
DETERMINATION MADE BY       EPA REGION VI                  JOHN BUNYAK                         (2141-767-1594
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHOUE)



PROCESSES SUBJECT                     THROUGHPUT         POLLUTANT    EMISSION  LIMITS                                    ...» BASIS
TO THIS PEP.MIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ... PCT EFF
BOILER, COAL FIRED UNIT *1
                                   6780.00  MMBTU/H
BOILER, COAL FIRED UNIT 32
6780.00 MMBTU/H
                                                          PM
                                                          S02
                                                          NOX
                                                          CO
                                                           PM
                                                           S02
                                                           NOX
                                203.0000
                                  0.0300

                                  0.7200
                               4882.0000

                                  0.6000
                               4068.0000

                                  0.1300
                                892.0000
LB/H
LB/MMBTU
ESP
LB/MMBTU
LB/H
DESULFURIZATION SYS.
LB/MMBTU
LB/H
BURNER DESIGN
LB/MMBTU
LB/H
BURNER DESIGN
                                203.0000 LB/H
                                  0.0300 LB/MMBTU
                                         ESP
                                  0.7200 LB/MMBTU
                               4882.0000 LB'H
                                         DESULFURIZATION SYS.
                                  0.6000 LB/MMSTU
                               4068.0000 LB/H
                                                                                                                             99.90
                                                                                                                             90.00
                                                                                                                             99.90
                                                                                                                             90.00
PAGE G-  93

-------
                                                                            BURNER  DESIGN
                                                           CO         0.1300  LB/HKBTU
                                                                   892.0000  LB/H
                                                                            BURNER  DESIGN
NOTES
                                                                                                     INITIAL REVIEW  POST STARTUP
<*) INDICATES DATUM WAS TRUNCATED FOR THIS  TABLE.                                        REVIEW STATUS:  CV01/19S3

PAGE G-  9^t                                          ID NUMBER TX-0015                                    SOURCE TYPE CODE    1.1

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                         05/22/1934



SOURCE TYPE/SIZE—         EXTERNAL COMBUSTION - COAL                                        720.00 MW


COMPANY NAME/SITE LOCATION  SW ELECT. POWER                                              HALLSVILLE, TX


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    PATE OF PERMIT ISSUANCE—  03/30/78
PERMIT NO. PSO-TX-64                                                                            ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY       EPA REGION VI                  JOHN BUNYAK                          (21A )-767-1594
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHCHE )



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                    ... 4 BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
•"• — — • — •--- — — — -• — «- — *• — — — — — — — — — — — — — — — — — — — — — — _— • — — — __ — •___^.___-. — — —._«.___-.-.-._ — ____ _„_ _ __»___^_____,. »_.. — .._ — .,____.._-_____ _ --__..._ _______.._ ™ —•_»«

COAL FIRED STEAM GEN                720.00 MW
                                                           S02       1.2000 LB/MM3TU
                                                                   682.0000 LB/H
                                                                            WET LIMESTONE  FGO                                76.00
                                                           PM        0.1000 LB/MM3TU
                                                                            ESP                                               99.00


NOTES —		















                                                                                                       TMTTTiL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        ntVXLri STATUS:   CH/01/1<=33

PAGE G-  95                                           ID NUMBER TX-OCS1                                     SCJ.RCE T'iPE CODE    1.1

-------
                                             APPENDIX -- DETAILED SOURCE  LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE---
                            EXTERNAL COMBUSTION -  COAL
                                                                                            500.00 MW
COMPANY NAME/SITE LOCATION  S.C. PUBLIC SERVICE  AUTHORITY
                            CROSS SITE
                                                                                            CROSS, SC
                                                             BERKELEY COUNTY
DETERMINATION IS BACT
PERMIT NO. P/C-08-190
DETERMINATION MADE BY
                            SOUTH CAROLINA DHEC
                             (AGENCY)
     OTTO PEARSON
  (AGENCY CONTACT PERSON)
DATE OF PERMIT ISSUANCE--  12/03/81
ESTIMATED DATE OF START-UP--
(803)-758-5406
    (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
S3 GENERATOR








THROUGHPUT POLLUTANT
CAPACITY EMITTED
500.00 MW
PM

S02

NOX

CO

EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

0.0300 LB/MMBTU
ESP
0.4100 LB/MMBTU
LOW S COAL
0.6000 LB/f."BTU
EQUIPMENT DESIGN S OPERATION
0.0400 LB/MMBTU
EQUIPMENT DESIGN & OPERATION
... & BASIS
... PCT EFF

NSPS
99.80
BACT
85.00
B/N

BACT

NOTES
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G-  96.
                                                                                                     INITIAL REVIEW  POST STARTUP
                                                                                        REVIEW STATUS:   04/01/1933     04/02/19S<+
ID NUMBER SC-C010
                                                     SOURCE TYPE CODE
                                                                         1.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/22/1984



SOURCE TYPE/SIZE—         EXTERNAL COMBUSTION - COAL                                      1600.00 MMBTU/H


COMPANY NAME/SITE LOCATION  TACOMA CITY LIGHT                                               TACOMA, WA


DETERMINATION IS BACT FOR A NEW  SOURCE.                                                        DATE OF PERMIT ISSUANCE—  05/11/82
PERMIT NO. (REGION FILE NO.) PSD-X-82-06                                                       ESTIMATED DATE OF START-UP—
DETERMINATION MADE BY       EPA  REGION X                   DAVID TETTA                         (206 )-<+<»2-1597
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                    THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... t BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF
BOILER
                                   1600.00 MMBTU/H
                                                          S02


                                                          S02

                                                          NOX

                                                          NOX
               0.2300
             367.0000

            1366.0000

               0.5000
             786.0000
            2926.0000
LB/MMBTU
LB/H
DRY SCRUBBER
T/YR
DRY SCRUBBER
LB/MMBTU
LB/H
T/YR
85.00

85.00
NOTES
(*) INDICATES DATUM WAS TRUNCATED FOR  THIS  TASLE.

PAGE G-  97
                                                                                                     INITIAL  REVIEW   POST  STARTUP
                                                                                        REVIEW STATUS:   04/01*933
ID NUMBER1 WA-0006
                                                     SOURCE TYPE CCDE
                                                                         1.1

-------
                                             APPENDIX  —  DETAILED  SOURCE  LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE-—         EXTERNAL COMBUSTION - COAL                                       425.00  I1W


COMPANY NAME/SITE LOCATION  TAMPA ELECT.  CO.                                                 RUSKIN,  FL 33601
                            P.O. BOX 111                                                                        HILLSBOSOUGH COUNTY


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE  OF PERMIT ISSUANCE--  10/15/81
PERMIT HO. (REGION FILE NO.) FSD-FL-OHO                                                        ESTIMATED DATE OF START-UP—   19S1
DETERMINATION MADE BY       FLORIDA DER                   BOB KINS                             (904J-488-1344
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHOME )



PROCESSES SUBJECT                     THROUGHPUT       POLLUTANT     EMISSION  LIMITS                                    ...  & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ...  PCT EFF
BOILER, COAL FIRED
                                    425.00 MW
                                                          PM         0.0300  LB/MT.6TU
                                                                  130.0000  LB/H
                                                                            ESP
                                                          S03        0.8200  LB/MMSTU
                                                                 3576.0000  LB/H
                                                                            LIMESTONE  SCRUBBER
                                                                            COAL WASHING
                                                          NOX        0.6000  L6/t"',6TU
                                                                 2598.0000  LB/H
                                                                            EQUIPMENT  DESIGN  4 OPERATION
                                                          CO         0.0140  LB/KMBTU
                                                                   61.0000  LB/H
                                                                            EQUIPMENT  DESIGN  & OPERATION
                                                                       NSPS

                                                                       99.00
                                                                       NSFS

                                                                       90.00

                                                                       BACT


                                                                       BACT
NOTES 	
BIG BEND STATION UNIT S4.
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G-  98
                                                INITIAL REVIEW  POST STARTUP
                                   REVIEW STATUS:  04/01/1
-------
    -
o
z
UJ
13

~
















^^
>-
^
UJ

2
























ii
n
ii
n
n
n
n
n
n
u
n
n
u
n
n
n
n
n
n
ii
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
u
n
n
n
u
tt
n
n
M
n
n
n
ii
n
n
n
u
n
n
u
n
n
n
n
n
n
n
ii
ii
n
ii
n
n
u
u
n
n
n
i
n
n
i
n
n
n
n
i
n
n
n
ii
n
u
n
i
n
n
n
n
n
M
it
n
H
n
n
u
n
n
i
n
i
n
n
i
i
i
i
i
i
t
i
i
i
i
i
ii
n
n
n
n
n
n
n
V) u.
HI U-
vi uj

CD t-
CJ
•a a.


, ,
« •


z
o
M
H-

O
HI
U.
HI
O
O
E

in
in
UJ
8
or
a

o:
o

k~
z
UJ
E
a.
HI
a
UJ
in
H- -1
M 0
E a:
M H-
-J Z
O
Z O
o
M
in
in
M

UJ



5a
< UJ

5 H-
-J HI
-1 E
O UJ
a.






t-
3 >-
D. H-
Z M
13 O
D <
O a.
CK <
I O
H-
















H-
u
LU
-> r-
gj HI
in a
UJ
in a.
UJ
in in
in HI
uj :c
0 H-
o
o: o
CJL H~
o
o
t
in
CO
























in
z
cc o
UJ HI
CD H-
CO <
3 U
a HI
u u.
in M
o
UJ O
0 *"
H. Z
10 o
g ^?P?
co HI co in m
E x "* § to £
X X >- X K X
CO CO O: CO O CD
_J _J 0 _l U -J

o o o o
<
0 0 E
in z o.














o
o
t
o
in
ro











in
t—
M

5

»
^r
UJ
CD


UJ
a-
Hl
U.

—1
O
u
•o

•
o^
o-







































UJ
in in
SH-
Hl
I 1-
O HI
•< — 1
CO
z
o
HI
in
in
HI
E
UJ

O
CO

u.
o

z
o
HI
H-
HI
E

UJ
H-
UJ
a

UJ
£

z
HI

O
UJ

in
a.
z

g

-------
                                            APPENDIX ~ DETAILED SOURCE LISTING
                                                                                                                       05/22/1984
SOURCE TYPE/SIZE---
                            EXTERNAL COMBUSTION - COAL
                                                                                            700.00 MW
COMPANY NAME/SITE LOCATION  TUCSON ELECT.  POWER CO. UNITS SI & 2
                                                                                           TUCSON, AZ
                                                                                                                    APACHE COUNTY
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT NO.  (REGIOH FILE NO.) AZ77-01
DETERMINATION MADE BY       EPA REGION IX
                             (AGENCY)
     DAVID  SOLOMON
  (AGENCY CONTACT PERSON)
                                                                                              DATE OF PERMIT ISSUANCE--  12/21/77
                                                                                              ESTIMATED DATE OF START-UP-
                                                                                              (415 J-974-8066
                                                                                                  I PHONE)
PROCESSES SUBJECT THROUGHPUT
TO THIS PERMIT CAPACITY
COAL FIRED GEN. UNITS, 2 350.00 MW EA





COAL HANDLING

POLLUTANT
EMITTED

PM

SO 2

NOX

PM
EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

0.0340 LB/MM3TU
HOT SIDE ESP
0.6900 LB/Mr3TU
KET LIME SCRUBBER
0.6970 LB/M:!3TU


... & BASIS
... PCT EFF

BACT

BACT
64.00
NSFS


BOTTOM ASH
FLY ASH
                                                          PM
                                                          PM
                                                                           SPRAY APPLIC. & DUST COLLECT
                                                                           HYDRALIC CONVEYANCE
                                                                           PNE'JMATIC CONVEYANCE
NOTES 	
DETAILED CONTROL STRATIGIES FOR THESE FACILITIES  IS GIVEN IN PERMIT. WET SUPPRESSION SHALL BE USED TO CONTROL FUGITIVE DUST DU
RING CONSTRUCTION. SAMPLING OF COAL IS REQUIRED.  THIS DEGREE OF CONTROL WAS PROPOSED BY THE CO. IN ITS A PPLICATION.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 100
                                                                                                     INITIAL REVIEW  POST STARTUP
                                                                                        REVIEW STATUS'-  CH/01/1Q83
ID NUMBER AZ-C002
                                                     SOURCE TYPE
                                                                         1.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE—-
                            EXTERNAL COMBUSTION - COAL
                                                                                            200.00 MM3TU/H
COMPANY NAME/SITE LOCATION  TVA -  AFBC  PILOT PLANT - SHAWNEE STEAM *
                            AFBC PILOT  PLANT
                                   PADACAH, KY 42001
                                                                                                                 MCCRACKEN  COUNTY
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT NO. C-80-18
DETERMINATION MADE BY       KENTUCKY  DAPC
                             (AGENCY)
   BILL DILLS
(AGENCY CONTACT PERSON)
DATE Or PERMIT ISSUANCE—  04/14/80
ESTIMATED DATE OF START-UP—   1962
(502)-564-3382
    (PHONE)
PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ...  4 BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ...  PCT  EFF
	•	.	»	,	—	,	

FLUIOIZED BED BOILER                200.00 MKBTU/H
                                                          S02       1.2000 LB/MMBTU                                         BACT
                                                                           FLUIOIZIED BED COMBUSTION                        85.00
                                                          PM        0.1000 LB/flMBTU                                         BACT
                                                                           BAGHOUSE                                         99.90


NOTES 	















                                                                                                     INITIAL REVIEW  POST  STARTUP
(*) INDICATES DATUM WAS TRUNCATED  FOR  THIS TABLE.                                        REVIEW STATUS'-  04/01/1933     02/1V19S4

PAGE G- 101                                          ID NUMSER KY-0007                                     SOURCE TYPE  CODE    1.1

-------
CJ  M
CJ  II
X  II



























3
XI

o
o
•
o
ro
CJ

































_j

o
u

1
o
w
OKBUST
CJ



Z
or
UJ
H-
X
UJ







t
i
I
UJ
N
M
in
LU
O.
H-
UJ
CJ
b
to
1 >
(-
z
^J
o
o

CD
§
19

uj
—J
eP

jc











^~
^






































o
CL'
O
CO
V)
UJ
y
tt
o

1
UJ 15
to a
M —I
0 tt

a o
< u
a D:
a
1 UJ
< o
> oj
t— f^

z
o
M
h-

U
O


UJ
1-
H
in
LU
z
z

a.
g
u
O- i-l

N. o-
UI rH
CJ
X
•o
0 1
1
a
1 13
i i
UJ H-
cj D:
Z "^
- >-
LU ^ O
M CJ Z
u. n LU
M t- ID
0 2 <
O LU —
r ^

"*
D:
0
u.

CJ CD

CO Is- UJ
~
o o:
o: a: x <
>- >- CD 1—
N N < O
t- H- co n:

o o
o o
O 0

, ,
l/t -0
e\j ro
fO rH





E i?






-J

O
U
«. x
h- K
o o
0 0
o o
o o
o o
CJ CJ














2 I—
< z
-1 <
a. -i
Q.
CD
z o
HI Z
in x
3 in
a •*
u 3

o o
U 0





,

>.
a
h*

O
10

2
*t
tc
J_

(O
to
UJ
— J

u_
o

t
4
t

UJ
-J
£D

I
_j
_j •
< u.
u.
Z UJ

x
H- ro
O. o
UI
u a.
u r:
< 5
o
o
H- n:
CD CJ
z
M >-
— J D:
— ' •<
M H-
2 0
oc
tn
HI •
D:
^ UJ
> <
H~ „}

ui to
U M
M K
10 M

CC
i : LU
• jQ_
tn o
UJ LU —I
t— tt *f

t- D O
to cy t~i
UJ h-
Z£ D' M
o tn Q
MHO
H- <
2: o to
31 —I X
D: O H-
UJ U.

UJ V- 1**
Ct UJ N.
(0 O
1 U. 1
U. rH
< O CO
UJ 1
0:0:0
- h-
)- _J H
H *T H
< 2 o:
-
UJ  1*1  ll  K-
M  CO  II
>  a*  n  LU
LU  rH  II  U
        II
                                                                                                                                                                  -J o
                                                                                                                                                                  < s.
        I  O
        i  in

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE—-
                            EXTERNAL COMBUSTION - COAL
                                                                                            1600.00 MW
COMPANY NAME/SITE LOCATION  UTAH Pk'R «  LT CO-HUNTER STATION
                            NEAR CASTLE DALE
                                            UT
                                                                                                                      EMERY COUNTY
DETERMINATION IS BACT FOR A MODIFIED  SOURCE.
PERMIT NO.
DETERMINATION MADE BY       EPA REGION VIII
                             (AGENCY)
   JOHN DALE
(AGENCY CONTACT PERSON)
DATE OF PERMIT ISSUANCE—  06/02/80
ESTIMATED DATE OF START-UP—   1983
(303)-837-3763
    (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
ACTIVE STORAGE



ASH SILO UNLD


ASH SILO VENT



BOILER, 84







THROUGHPUT POLLUTANT
CAPACITY EMITTED

PM

VE

VE


PM

VE
860.00 MW
NOX

PM

S02

VE
EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

2.0000 LB/H
SPRAY & ENC.
20.0000 '/. OPACITY

20.0000 7. OPACITY
KEPT DAMP

49.0000 LB/H
FF
20.0000 7. OPACITY

0.5500 LB/MM3TU
BOILER DESIGN
0.0300 LB/MM3TU
FF
0.1200 LB/MHBTU
SCRUBBER
20.0000 •/. OPACITY
... t BASIS
. . . PCT EFF

BACT
90.00


BACT
100.00

BACT
99.80


BACT
65.00
BACT
90.00
BACT
90.00

PAGE G- 103

-------
 (CONTINUED) UTAH PUR & LT CO-HUNTER STATION
PROCESSES SUBJECT
TO THIS PERMIT
CONV



HAUL ROADS


INACT STORAGE



LIME T/S


SLUDGE MIX(ASH)


TRANS



TRUCK UNLD



===========s======s=========r=r===s====:
THROUGHPUT POLLUTANT
CAPACITY EMITTED
2.50 MMT/YR
PM

VE

PM


PM

VE

VE


VE

2.50 MMT/YR
PM

VE
2.50 MMT/YR
PM

VE
EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

5.0000 LB/H
ENC.
20.0000 7. OPACITY

2.7000 LB/H
ASPHALT + H20

40.0000 LB/H
SEAL. & COMP.
20.0000 7. OPACITY

20.0000 '/. OPACITY
FF

20.0000 •/. OPACITY
FF

1.0000 LB/H
SPRAYS * ENC.
20.0000 7. OPACITY

0.1000 LB/H
SPRAYS & ENC.
20.0000 7. OPACITY
... & BASIS
... PCT EFF

BACT
90.00


BACT
90.00

BACT
90.00


BACT
99.80

BACT
99.80

BACT
98.50


BACT
98.50

NOTES		
CEM QA REQUIRED BY 40CFR, PART 60, SUBPART DA.  BOILER  EMISSION COMPLIANCE  FOR  SOX,  NOX,  OPACITY  WILL BE DETERMINED BY CEM REPO
RTS.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 104
         INITIAL PEVIEH  POST STARTUP
L^ 3'iAluS-   04/01/1933    02/13/198'+
                                                     ID NUMBER UT-0021
                                                                                                           SO'JSCE  TYPE  CODE
                                                                                                                               1.1

-------
                                            APPENDIX  — DETAILED  SOURCE  LISTING
                                                                                                                        05/22/19S*



SOURCE TYPE/SIZE—         EXTERNAL COMBUSTION  -  COAL                                      2080.00 MW
                           — — — — — — — — — —— — — — — — — — — —^ — — — __ — — _ — -. — __ — _ — -.•__ —™.__^____™_»_ —_• —_^.___ —— _-. — ___ — —«._ — __«_^_ — «.__ — •_ — — _______„__»_

COMPANY NAME/SITE LOCATION  WASHINGTON WATER POWER CO.                              -              , WA


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—  11/17/82
PEPMIT NO. (REGION FILE NO.) PSD-X-S3-01                                                        ESTIMATED DATE OF START-UP—   198*
DETERMINATION MADE BY       EPA REGION X                   PAUL BOYS                            (206 )-<+42-1567
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT       POLLUTANT    EMISSION LIMITS                                    ... & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ... FCT EFF
CGS BOILER
ROTARY CAR DUMPER (COAL)
ROTARY CAR DUMPER (LIMESTONE)
S02       0.2200 LB/KKBTU 300 R AV
       11*0.0000 LB/H 24H D AV
NOX       O.SOOO LB/MMBTU S3. COAL
          0.6000 LB/t-TSTU BIT. COAL
                 LIMITS ARE 30 DAY ROLLIN AVG
PM        0.0300 LB/NM3TU
VE       20.0000 7. OPACITY
CO      332.0000 LB/H
VOC       3.3200 LB/H
PB        0.2700 LB/H ANNUAL AV
BE        0.0200 LB/H ANNUAL AV
HG        0.0300 LB/H ANNUAL AV
F         1.1500 LB/H ANNUAL AV
SUL*     80.9000 LB/H ANNUAL AV

PM        0.0100 GR/DSCF
                 BAGHCUSE
VE        5.0000 •/. OPACITY

PM        0.0100 GR/DSCF
                 BAGHOUSE
VE        5.0000 7. OPACITY
                                                                                                                             90.00
                                                                                                                             90.00
PAGE G- 105

-------
(CONTINUED) WASHINGTON WATER  POWER  CO.
PROCESSES SUBJECT
TO THIS PERMIT
CONVEYORS



COAL CONVEYOR DISCHARGE



COAL CONVEYOR TRIPPERS



TRANSFER HOUSES



COAL SUPPLY SYSTEM



COAL SILOS



LIMESTONE SILOS



BOTTOM ASH DISPOSAL

THROUGHPUT POLLUTANT
CAPACITY EMITTED

PM

VE

PM

VE

PM

VE

PM

VE

PM

VE

PM

VE

PM

VE

PM
EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

0.0100 GR/DSCF
BAGHO'JSE
5.0000 V. OPACITY


TELESCOPIC CHUTES/LOWERING WELL
20.0000 X OPACITY

0.0100 GR/DSCF
BAGHOUSE
5.0000 X OPACITY

0.0100 GR/DSCF
BAGKQUSE
5.0000 X OPACITY

0.0100 GR/DSCF
BAGHOUSE
5.0000 X OPACITY

0.0100 GR/DSCF
BAGHOUSE
5.0000 X OPACITY

0.0100 GR/DSCF
BAGHCUSE
5.0000 X OPACITY


... & BASIS
... PCT EFF


99.00



75.00



99.00



99.00



99.00



99.00



99.00



                                                                           FIXATED W/SCRUBBER SLUDGE
                                                                                                                           100.00
PAGE G- 106

-------
(CONTINUED) WASHINGTON WATER POWER  CO.
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
& BASIS
PCT EFF
ROAD DUST
FLY ASH HANDLING t SILOS
WASTE TREATMENT BLDG.
DEAD STORAGE
                     PM


                     PM

                     VE

                     PM

                     VE

                     PM

                     VE
                    CHEM. STABILIZ..DESIGN 8 OPER. PRACT.

             0.0100 GR/DSCF
                    BAGHOUSE
             5.0000 X OPACITY

             0.0100 GR/DSCF
                    BAGHOUSE
             5.0000 y. OPACITY

            20.0000 GR/DSCF
                    SURFACE STABILIZATION
            95.0000 7. OPACITY
                                                                                                                             85.00
                                                                                                                             99.00
                                                                                                                             99.00
NOTES 	
THE PROPOSED CONTROL SYSTEM CONSISTS  OF  A  LIMESTONE FGD SYSTEM FOR S02 REMOVAL FRECEEDED BY A BAGHOUSE  (OR  POSSIBLY AN  ESP)  FO
R PARTICULATE REMOVAL.  THE APPLICABLE TRACE MATERIALS WILL ALSO BE REMOVED TO SOME EXTENT
BY THE PARTICULATE AND  SQ2 CONTROL SYSTEMS. NOX.CO.VOC ARE MINIMIZED BY COMBUSTION CONTROL (IE. EXCESS  AIR  CONTROL, ETC.). AMO
UNTS SITED ARE EMISSIONS PER UNIT.
(*> INDICATES DATUM WAS TRUNCATED  FOR  THIS TABLE.

PAGE G- 107
                                                                INITIAL REVIEW  POST STARTUP
                                                   REVIEW STATUS:  C4/01/19S3
                                                     ID NUMBER WA-0003
                                                                                                          SOLACE TYPE  CCDE
                                                                                                                               1.1

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                         05/22/192.4



SOURCE TYPE/SIZE	         EXTERNAL COMBUSTION - COAL                                       640.00 MW (NET)


COMPANY NAME/SITE LOCATION  WEST TEXAS UTILITIES CO.                                      OKLAUNION, TX
                                                                                                                  WILBERGER COUNTY

                               tf
DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—  05/20/82
PERMIT HO. 9015                                                                                ESTIMATED D4TE OF START-UP--    1932
DETERMINATION MADE BY       TEXAS ACB                      JAMES CROCKER                       (512 )-451-5711
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    . . . i BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... FCT EFF
._.»_..._._.	_ — — ___	— — __......___.._	»_ — __»„	_______	„	—— —	— .._ — — — __	......	—	-.____ —	«.	„_	— _	— _ „	_.__	._..___..-.__..__

STEAM GENERATOR                       6.80 MMMBTU/H
                                                           PM        0.0300 LB/MMBTU                                         NSPS
                                                                            ESP                                              99.70
                                                           S02       0.5000 LB/MM3TU                                         NSPS
                                                                            WET LIMESTONE SCRUBBER                           70.00
                                                           NOX       0.5000 LB/ttMBTU
                                                                            LOW NOX BURNERS
COAL & LIMESTONE STORAGE/HANDLI*
                                                           PM       60.0000 LB/H
                                                                            DUST CONTROL SYSTEM


NOTES 	
THIS IS A COAL FIRED BOILER BURNING LOW SULFUR COAL ( .bV/. S WORST CASE).









                                                                                                      INITIAL REVIEW  POST STARTUP
<*) INDICATES DATUM WAS TRUNCATED FCR THIS TABLE.                                         REVIEW STATUS:   04/01/1<533

PAGE G- 108                                           ID NUMBER TX-C012                                    SCL'SCE TYPE CCDE    1.1

-------
                                            APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                        05/23/198'+
SOURCE TYPE/SIZE---         EXTERNAL COMBUSTION  - COAL                                       1160.00  MW


COMPANY NAME/SITE LOCATION  WISCONSIN ELEC.  POWER CO., PLEASANT PRA*                               ,  HI
                                                                                                                    KENOSHA COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                         DATE  OF PERMIT ISSUANCE—  08/09/76
PERMIT NO. EPA-5-76-A-1                                                                        ESTIMATED DATE OF START-UP—   1980
DETERMINATION MADE BY       EPA REGION V                  BONIFACE THAYIL                      (312 )-8S6-6C54
                             (AGENCY)                   (AGENCY CONTACT  PERSON)                     (FHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION  LIMITS                                    ...  S BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT  OR  PROCESS MODIFICATION  ...  FCT EFF
	,	.	

BOILER, COAL FIRED, Z EA            560.00 MW
                                                          PM         0.1000 LB/MMSTU                                          NSPS
                                                                           ESP                                               99.00
                                                          S02        1.3000 LB/MMBTU  COAL                                     NSPS
                                                                     o.eooo LB/r;r:3TU  OIL
                                                                           LOW  S FUEL  --  <0.7X COAL,  <0.5X OIL


NOTES 	















                                                                                                      INITIAL REVIEW  POST  STARTUP
(*) INDICATES DATUM WAS TRUNCATED  FOR THIS TABLE.                                        REVIEW STATUS:   0^/01/1983

PAGE G- 109                                          ID NUMBER WI-0030                                     S^L'^CE TYPE CCOE    1.1

-------
                                             APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE---
EXTERNAL COMBUSTION  -  COAL
                                                                                            400.00 MW
COMPANY NAME/SITE LOCATION  WISCONSIN POWER &  LIGHT CO.,  EDGEWATER *
                                                                                        SHEBOYGAN, WI
DETERMINATION IS BACT FOR A HEM SOURCE.
PERMIT NO. EPA-5-77-A-3
DETERMINATION MADE BY       EPA REGION V
                             (AGENCY)
                              BONIFACE THAYIL
                            (AGENCY CONTACT  PERSON)
                                       DATE OF PERMIT ISSUANCE--  04/36/77
                                       ESTIMATED DATE OF START-UP—
                                       (312)-886-6054
                                           (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
          THROUGHPUT
           CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT 03 PROCESS MODIFICATION
& BASIS
PCT EFF
BOILER, COAL FIRED
                                    400.00  MM
                                                          PM
                                                          S02
                                        0.1000  LB/MMBTU
                                        1.2000  LB/MM3TU
                                                                     NSPS
                                                                     NSFS
NOTES
(*) INDICATES DATUM WAS TRUNCATED FOR THIS  TABLE.

PAGE G- 110
                                                                                                     INITIAL REVIEW  POST STARTUP
                                                                                        REVIEW STATUS-'  04/01/1933
                         ID NUMBER WI-0029
                                                                              SOURCE TYPE CCDE
                                                                                                  1.1

-------
                                             APPENDIX  — DETAILED  SOURCE  LISTING
                                                                                                                        05/22/198<+
SOURCE TYPE/SIZE—-
                            EXTERNAL COMBUSTION  -  COAL
                                                                                             321.00 MV4
COMPANY NAME/SITE LOCATION  WISCONSIN PUBLIC SERVICE CORP., WESTON
                                                                                                                   MARATHON COUNTY
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT NO. EPA-5-77-A-4
DETERMINATION MADE BY       EPA REGION V
                             (AGENCY)
PROCESSES SUBJECT
TO THIS PERMIT
                     BONIFACE THAYIL
                  (AGENCY CONTACT PERSON)
                                                         DATE OF PERMIT ISSUANCE—  05/11/77
                                                         ESTIMATED DATE OF START-UP--
                                                                                                   ( PHONE )
THROUGHPUT
 CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
t BASIS
PCT EFF
BOILER, COAL FIRED
                                    321.00 MW
                                                           FM
                                                           S02
                               0.1000 LB/MM3TU
                               1.2000 LB/Mf!BTU
                                                                      NSPS
                                                                      NSPS
NOTES
(*> INDICATES DATUM WAS TRUNCATED FCR THIS  TABLE.

PAGE G- 111
                                                                INITIAL REVIEW  POST STARTUP
                                                   REVIEW STATUS:  04/01/1933
                                                      ID NUMBER WI-0028
                                                                                                           SC'J"CE TYPE CCDE
                                                                                                                               1.1

-------
                                             APPENDIX  —  DETAILED  SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE---         EXTERNAL COMBUSTION - OIL


COMPANY NAME/SITE LOCATION  ANGUS PETROTECH                                                       »  CA


DETERMINATION IS BACT FOR A NEW SOURCE.                                                         DATE  OF PERMIT ISSUANCE--  11/29/83
PERMIT NO. 4132002-004                                                                         ESTIMATED DATE OF START-UP--
DETERMINATION MADE BY       KERN COUNTY  APCD               TOM PAXSON                          <805 )-661-36S2
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (FHOfJE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION LIMITS                                   ... 4 BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
______ — ____•_«__ — •_« __»_«___.« ____ — — ___ — ____. — — — — .-- — — — — — —— __ — —. — __ — — — — — — ^ — — — — — — — — — — —. — — — — — — •- — — — — — — — — — — — — — — — — — —— — — — — — — — — — — — — — — — — — — — — — _ -. —

BOILER, OIL FIRED                    62.50 MMBTU/H
                                                           S02     61.4000 LB/D
                                                                            SCDIUM BASED SCRUBBERS
                                                           NOX     199.0000 LB/D
                                                                            LOW  NOX BURNERS


NOTES —	-
(»> INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 112
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW STATUS:
ID NUMBER CA-0069
                                                     SC'JRCE TYPE CODE
                                                                         1.2

-------
                                            APPENDIX -- DETAILED SOURCE LISTING
                                                                                                                       05/22/1984



SOUPCE TYPE/SIZE-—         EXTERNAL COMBUSTION - OIL                                         81.90 MSTU/H


COMPANY NAME/SITE LOCATION  HOOKER  CHEMICAL & PLASTICS CORP.                            PERRYVILLE, MO 21903
                            P.O.  BOX D                                                                                CECIL COUNTY


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT  ISSUANCE--   07/03/79
PERMIT HO. 78MD07                                                                             ESTIMATED DATE  OF  START-UP—    1930
DETERMINATION MADE BY       EPA REGION  III                 BOB BLASZCZAK                       ( 215 J-597-8186
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                    THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... *  BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... FCT EFF


OIL FIRED BOILER                     81.90 MK3TU/H
                                                          S02     355.1000 LB/H                                              BACT
                                                                           S IN FUEL  LIM. TO 1.3X  BY WT


NOTES -----------
355.1 LB/H, 3 BOILERS (2 EXISTING & 1 NEW) WITH COMMON STACK

NEVER BUILT - COMPANY OUT OF BUSINESS
                                                                                                                           STARTUP
(*) INDICATES DATUM WAS TRUNCATED  FOR  THIS TABLE.

PAGE 6- 113
                                                                                        kEVItW STATUS:   04/01/1933
                                                                                                                               1.2

-------
                                             APPENDIX  --  DETAILED SOURCE LISTING
                                                                                                                        05/22/1934



SOURCE TYPE/SIZE---         EXTERNAL COMBUSTION - OIL                                         185.00 MM3TU/H EA
                           	

COMPANY NAME/SITE LOCATION  HOUSTON LIGHTIH3 & POKER                                               » TX 77001
                                                                                                                  MATAGORDA COUNTY
                           __ _ __ _ _ ____.-.-.___ ___..___-.____.— — __. — — — — — — _ — — — —— — — — — — — — _ —— .___«,___ —.. _______ _ — _ _ _—. — —._ — _....____-.___ _ _ _ _ _______

DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE--  01/16/80
PEPMIT NO. (REGION FILE NO.) PSD-TX-209                                                        ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY       EPA REGION VI                  JOHN  BUNYAK                         (214>-767-1594
                             (AGENCY)                   (AGENCY  CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... * BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ... PCT EFF
	

BOILER, Z EA                        185.00 MMBTU/H
                                                           S02       0.5000 LB/MMSTU                                         BACT
                                                                    92.1000 LB/H
                                                                            LOW SULFUR *2 FUEL OIL
                                                           PM        0.1000 LB/MM3TU                                         BACT
                                                                    18.3500 LB/H
                                                                            FGD
                                                                            02 CONTROL
                                                           NOX       0.3000 LB/MMSTU                                         BACT
                                                                    55.0000 LB/H
                                                                            LCW NOX BURNER
                                                                            LEA FIRING


NOTES 	
NO. 2 FUEL OIL — < 0.5X SULFUR BY WT. CONTINUOUS OPERATION — 8760 HR/YR







                                                                                                      INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:  04/01/1933

PAGE G- 114                                           ID  NUMBER  TX-0013                                    SOU'SCE TYPE CODE    1.2

-------
                                             APPENDIX  —  DETAILED  SOURCE  LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE—         EXTERNAL COMBUSTION  -  OIL
                           — ——— — — — ——————— — —————— — -- — __ _ — __ — ___•_-._ ____ _ — „_ — _—. ____..____ __—___— ___.._ __»,.._ _ A«»_ UU_.V^_1»»___W— V__.v«««.____^_

COMPANY NAME/SITE LOCATION  NORTHERN INDIANA PUBLIC SERVICE  CO. , SC*                               ,  IN
                                                                                                                     JASPER COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE  OF PERMIT ISSUANCE—  03/16/79
PERMIT NO. EPA-5-79-A-25                                                                       ESTIMATED DATE OF START-UP—
DETERMINATION HADE BY       EPA REGION V                  BONIFACE THAYIL                      (312)-eS6-6054
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHC1IE)



PROCESSES SUBJECT                     THROUGHPUT       POLLUTANT     EMISSION LIMITS                                   ... & BASIS
TO THIS PERMIT                         CAPACITY           EMITTED             CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ... PCT EFF


GENERATOR, OIL FIRED, 2
                                                          S02
                                                                            LIMITED TO O.SX S FUEL OIL
                                                          NOX      75.0000  PFM


NOTES 	
EACH TURBINE RESTRICTED TO 2000 H/YR















                                                                                                      INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEW STATUS:   OVOl^SS

PAGE G- 115                                           ID  N'JJIBER IN-0024                                     SC'JSCE TYFE CODE    1.2

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                         05/22/1984



SOURCE TYPE/SIZE---         EXTERNAL COMBUSTION - NATURAL GAS                                 18.00 KW


COMPANY NAME/SITE LOCATION  APPLIED POWER TECHNOLOGY                                      OROVILLE, CA
                           — — — — — — — — — — — — — — — — — — — — — — — — — — — ——~ — — — — — — — — — — — — — — — _ — — — — — _ — —.——_«.—._______ — —^.___»_ —— _-.___ — «___ — _____________ —__.

DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE Of PERMIT ISSUANCE—   11/29/83
PERMIT NO. SAC 83-02                                                                           ESTIMATED DATE OF START-UP--
DETERMINATION MADE BY       EPA REGION IX                  JOE SLAMOVICH                       (415)-974-8235
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (FHCNE )



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... FCT EFF
	—	— —	—	— —	— —	— —	— — — — — —	— — —	—	— _ — ..-. — — .. — _ — • —	— _ —	_	__	_	__	_ _ _ _	»., — _...,____ — .. __ — ____«.	„	

BOILER, 2                           307.10 MI1BTU/H
                                                           PM       11.9000 LB/H
                                                                            ESP & MULTICLONES                                96.70
                                                           NOX      35.4000 LB/H
                                                                            ccr;3USTioN CONTROLS


NOTES 	
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PA3E G- 116
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS;
                                                      ID  NUMBER  CA-0066
                                                                                                           SOURCE TYPE CODE
                                                                                                                               1.3

-------
                                             APPENDIX  —  DETAILED  SOURCE LISTING
                                                                                                                        05/22/1934
=.^z = =; = - = i:- — -zz = =-----~-- = = -~- = --z:~- = = --~~--- = -~-- = --~~- = ~--~ — ---- — = -—~ — -~~-~ = -~~--~:::- = -~~~~~ = ~ = ~~::~	'	


SOURCE TYPE/SIZE-—         EXTERNAL COMBUSTION -  NATURAL GAS                                 175.00 MLB/H
                           	-----------—--

COMPANY NAME/SITE LOCATION  CONSUMERS POWER CO.                                            MIDLAND, MI


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT  ISSUANCE-   06/01/81
PERMIT NO. 99-81                                                                               ESTIMATED DATE  OF  START-UP--   1932
DETERMINATION MADE BY       MICHIGAN DNS                   DAVID FERRIER                       (5171-3C2-1333
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (FHCNE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ••• & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ... PCT EFF
	___	_	— — —	— —	_ —	— —	—	«.-,,___.,_.- — — —	. _ — _	-.»_ — — — — —	— — — —	— — — —	— — — —	— — — —	—	—	—	—	"*	•"• —


BOILERS, NAT. GAS, 3 EA             175.00 MLB/H
                                                           NOX       0.2000 LB/MHBTU
                                                                            BURNER DESIGN & EX. AIR CONTRL



NOTES 	
3 NATURAL GAS-FIRED BOILERS.
 <*)  INDICATES  DATUM  WAS TRUNCATED  FOR THIS TABLE.

 PAGE G-  117
                                                                                                       INITIAL REVIEW  POST STARTUP
                                                                                          REVIEW STATUS:  e4/01/1933    03/13/1984
ID NUi!3ER MI-0013
                                                      SG'JRCE  TYPE  CODE
                                                                          1.3

-------
                                             APPENDIX -- DETAILED SOURCE  LISTING
                                                                                                                        05/32/1984
SOURCE TYPE/SIZE---         EXTERNAL COMBUSTION  - NATURAL GAS


COMPANY NAME/SITE LOCATION  MQBAY CHEMICAL CORP.                                       KANSAS CITY, MO
DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—   08/16/83
PERMIT NO. 485                                                                                ESTIMATED DATE OF START-UP--   1984
DETERMINATION MADE BY       KANSAS CITY  AQS                LARRY COLE                          (816)-274-25Cl
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     IPHCHE )
PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION  LIMITS                                    ...  & BASIS
TO THIS PERMIT                         CAPACITY           EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ...  PCT  EFF
	.	

BOILER, 2 TOTAL                     198.60 MMBTU/H
                                                          NOX        0.2000 LB/HMBTU                                         NSPS
                                                          S02              MINIMIZE
                                                          VOC              MINIMIZE
                                                          FM               MINIMIZE
                                                          CO               MINIMIZE


NOTES 	
SOURCE TEST FOR NOX BY MAY 1984. ALLOWABLE FUELS ARE NATURAL GAS /  *3 FUEL OIL.
                                                                                                      INITIAL REVIEW   POST  STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEW  STATUS:   C4/13/19S4
PASE G- 118
                                                      ID  NUMBER  MO-0006                                     SOURCE  TYPE  CODE     1.3

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/22/1984
SOURCE TYPE/SIZE—-
                            EXTERNAL COMBUSTION - NATURAL GAS
                                                                                           2000.00 HP
COMPANY NAME/SITE LOCATION  SOUTHERN NAT.  GAS
                                                                                       ENTERPRISE, MS
                                                                                                                    CLARKE COUNTY
DETERMINATION IS BACT FOR A MODIFIED SOURCE.
PERMIT NO. (REGION FILE NO.) PSD-MS-036
DETERMINATION MADE BY       MISSISSIPPI DNR
                             (AGENCY)
   DWIGHT WILEY
(AGENCY CONTACT PERSON)
DATE OF PERMIT ISSUANCE—  08/21/81
ESTIMATED DATE OF START-UP—
(60D-354-2550
    (PHONE)
PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ...  4 BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ...  PCT  EFF
- — —	— —	-—	— — — — —— — —— — ——— — — — — — — — — — — — *— — ——-—-. — — —-.—— — _ — — — __—»___._»._»_«._:	— „__..__..•..___..._..__.,..__...«.,.__«,_____	——„—-,•_—_._»__«.	_ __„ _

ENGINE, NAT. GAS                  14000.00  CF/H N. G.
                                                          NOX      37.4000 LB/H                                             NSPS
                                                                  163.9000 T/YR
                                                                           BOILER DESIGN & OPERATION
                                                          CO       10.5000 LB/H                                             NSPS
                                                                   46.2000 T/YR
                                                                           BOILER OPERATION & DESIGN


NOTES 	














                                                                                                     INITIAL REVIEW  POST  STARTUP
<*) INDICATES DATUM WAS TRUNCATED FOR THIS  TABLE.                                        REVIEW STATUS:  04/01/1=33

PAGE G- 119                                          ID NUMBER MS-0003                                    SOURCE TYPE  CODE     1.3

-------
                                             APPENDIX -- DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE—-         EXTERNAL COMBUSTION - WOOD WASTE                                 155.62 MMBTU/H
                           — — — —— — —— — — — — — — — — — — — — — — — —— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — -— — — — — •-—•— — — — — ---—-. — —. — -- — — — — -•—. — — •«.—

COMPANY NAME/SITE LOCATION  AFTON GENERATING CO.                                             AFTON, WY
                           — — — •— — —»——— — —— — — —— — —— ~ — ————— — — — — — — — ——— — -.— — — — •.— — —•!» — — — — •--— — —-.-. «-^ — • — — — —•,-. — — — — — ^— — • — ^»«-— __ — —.—__•.•.___•••__« _.«^

DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—  02/15/83
PERMIT NO. CT-483                                                                              ESTIMATED DATE OF START-UP—   1934
DETERMINATION MADE BY       WYOMING AQD                    LEE GRIBOVICZ                       (307)-332-3144
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... 4 BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
- — — —	—	— —	— —	— — — _—_	— — —	„_	_	—	— — —	_	«._—__».._	«._	_	„_ ___„	:	«,	_„	__—	„

BOILER, WOOD & BARK WASTE           155.62 MMBTU/H
                                                           PM        0.0500 GR/DSCF AT 127. C02                               BACT
                                                                     0.1000 LB/MM3TU
                                                                            MULTICLOHE & LOU ENERGY WET SCRUBBER             80.00
                                                           CO        0.4400 LB/MM3TU                                         BACT
                                                                            CCTBUSTION CONTROL
                                                           VOC       0.0900 LB/MMBTU                                         BACT
                                                           NOX       0.2400 LB/MtlBTU                                         BACT
                                                                            COMBUSTION CONTROL


NOTES 	
AS PERMIT CONDITION, AN ADJACENT LUMBER MILL WILL DISCONTINUE USE OF 2 WOOD WASTE BURNERS, A WOOD CHIP FIRED BOILER,  AND AN 01
L FIRED BOILER.










                                                                                                      INITIAL REVIEW   POST STARTUP
<*> INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEW STATUS:

PAGE G- 120                                           ID NUMBER HY-0003                                    SOURCE T1FE CCDE    1.4

-------
                                            APPENDIX -- DETAILED SOURCE LISTING
                                                                                                                       05/22/1984




SOURCE TYPE/SIZE—-         EXTERNAL COMBUSTION - WOOD WASTE


COMPANY NAME/SITE LOCATION  CO-GEN                                                   COEUR D'ALENE, ID
                           _„„»__ — _.... _ __ __,__—__ __.«•_ ___ —_—_————— . _ —.—— — — w ——————, — — — — —— — — « — ———— — — — — _ — — —-.— — — — ..•_ — __«.^^..^,. —~ —^ —^ —»—— •—^

DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF  PERMIT ISSUANCE—  03/15/83
PERMIT NO.                                                                                    ESTIMATED DATE OF  START-UP—    1983
DETERMINATION MADE BY       IDAHO AQB                      CLINT AYER                          (2081-334-5360
                             (AGENCY)                    (AGENCY CONTACT PERSON)                    (PHONE)

z = = r = = = = = r = = = = = = = = = = = = = = = = = = = = = = = = = = = = = === = = = = = = = = =: = = = r = = = ==r = = = = = = = = = = = = = = = = = = = === = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =

PROCESSES SUBJECT                    THROUGHPUT         POLLUTANT    EMISSION LIMITS                                    ... & BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF
	

BOILER, WOOD FIRED                  104.00 MMBTU/H
                                                          PM        3.9500 LB/H
                                                                           MULTICLONE & BAGHOUSE                            98.40
                                                          CO        5.9000 LB/H
                                                          NOX      19.0000 LB/H


NOTES 	
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 121
ID NUMBER ID-0001A
                                                INITIAL REVIEW  POST STARTUP
                                   REVIEW STATUS;  04/01/1933

                                                     SC'JHCE TYPE CODE    1.4

-------
                                             APPENDIX —  DETAILED  SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE	         EXTERNAL COMBUSTION - WOOD HASTE                                    6.00  MW


COMPANY NAME/SITE LOCATION  CO-GEN., INC.                                             COEUR  D'ALENE,  ID


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE  OF PERMIT ISSUANCE—  03/15/83
PERMIT NO. (REGION FILE NO.) PSD-X81-16                                                        ESTIMATED  DATE OF  START-UP—   1933
DETERMINATION MiDE BY       EPA REGION X                   PAUL  BOYS                            (206J-442-1193
                             (AGENCY)                  (AGENCY  CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT       POLLUTANT     EMISSION  LIMITS                                   ...  & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL  EQUIPMENT  OR  PROCESS  MODIFICATION  ...  PCT EFF
BOILER
                                      6.00 MH
                                                           PM


                                                           NOX

                                                           CO

                                                           VOC
  0.0340
 16.6000

  0.1700
 88.2000
  0.2200
117.6000
  0.0800
117.6000
LB/MMBTU
T/YR
ESP
LB/MM3TU
T/YR
LB/MMBTU
T/YR
LB/MMBTU
T/YR
99.00
BACT

BACT

BACT
NOTES 	
GENERAL DESIGN CONTRIBUTES TO REDUCTION OF  OIL POLLUTANTS AND  INCLUDES  1)  INCREASED BOILER HEIGHT FOR BETTER  EFFICIENCY,  2)  0V
ERFIPE ANO U?;DERFIRE AIR,  3) FEEDWATER HEATERS TO  INCREASE EFFICIENCY.
(») INDICATES DATUM WAS TRUNCATED FOR THIS  TABLE.

PA3E G- 122
                                                     ID NUMBER ID-0001
                                   TNTTTAL "EVIEW  POST STARTUP
                      KLVIt* SIAiUS:   0-+/01/1933

                                        SO'J-CE TYPE CODE    1.4

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1934



SOURCE TYPE/SIZE—         EXTERNAL COMBUSTION - WOOD WASTE


COMPANY NAME/SITE LOCATION  HAYFORK COGENERATION PROJECT                                           • CA


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF  PERMIT ISSUANCE—  12/14/83
PERMIT NO. TAC-012                                                                            ESTIMATED  DATE OF  START-UP—   1985
DETERMINATION MADE BY       NORTH COAST  UNITED AQMD        CHUCK SASSENRATH                    (707 >-443-3093
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHCN'E)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION  LIMITS                                    ... & BASIS
TO THIS PERMIT                        CAPACITY          EMITTED             CONTROL EQUIPMENT  OR PROCESS  MODIFICATION  ... FCT EFF


BOILER, WOOD WASTE                  236.00 MH3TU/H
                                                          PM         0.0400  LB/MMBTU
                                                                            MULTICLONE/ESP                                   99.30
                                                          NOX       0.1500  LB/MM3TU
                                                                            DESIGN
                                                          CO         0.3500  LB/M:!3TU
                                                                            COMBUSTION MODIFICATION
                                                          VOC       0.0700  LB/MKSTU
                                                                            DESIGN


NOTES 	
STATE FILE 9 A320-024











                                                                                                      INITIAL REVIEW  POST STARTUP
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEW  STATUS:

PAGE G- 123                                           ID NUMBER  CA-0070                                     SOURCE TYPE CODE    1.4

-------
                                             APPENDIX  — DETAILED  SOURCE  LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE—-         EXTERNAL COMBUSTION -  WOOD WASTE                                   50.00  M»


COMPANY NAME/SITE LOCATION  MCNEIL GENERATING STATION                                   BURLINGTON,  VT
                            BURLINGTON ELECTRIC LIGHT  DEP*


DETERMINATION IS BACT FOR A NEW SOURCE.                                                       DATE  OF PERMIT  ISSUANCE—   05/01/80
PERMIT NO.                                                                                    ESTIMATED  DATE  OF  START-UP--    1984
DETERMINATION MADE BY       VERMONT AEC                   HAROLD  GARABEDIAN                  (802)-62S-3395
                             (AGENCY)                  (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT       POLLUTANT     EMISSION  LIMITS                                    ... t BASIS
TO THIS PERMIT                         CAPACITY         EMITTED             CONTROL EQUIPMENT  OR  PROCESS  MODIFICATION   ... PCT EFF


WOOD FIRED FURNACE                  670.00 MMBTU/H
                                                          PM         0.0070  LB/MMBTU
                                                                     0.0070  GR/DSCF AT  12X  C02
                                                                            MEC.  DUST COLLECTOR & ESP                        99.90
                                                                            80X-MEC COLLECT. & 99.5X-ESP


NOTES 	
418000 ACFM AT 310F-CYCLONES-LARGE DIA. CERAMIC-24 TUBE, 58 IN. DIAMETER,  12.3 FT LONG, DELTA  P=3.4  IN. H20, INLET VEL. 63.1FT
/SEC-ESP-KEIGHTEO WIRE TYPE .TOTAL PLATE AREA 280000 SQ. FT.,SCA=672  SQ.  FT./1000 ACFM, LINEAR VEL.  3  FT/SEC
- 9 FIELDS, 119 GAS PASSAGES,  9 IN. PASSAGE SPACING, 45 FT GAS TRAVEL DISTANCE.
                                                                                                      INITIAL REVIEW  POST STARTUP
    INDICATES DATUM WAS TRUNCATED FCR THIS TABLE.                                        REVIEW STATUS:
PAGE G- 124                                           ID NUMBER VT-0002                                    SO'JRCE TYPE CODE     1.4

-------
^.
CO
O-

\
CM
CM
X.
in
o







































ID

M
t-
to
M


UJ
O



CO

O
UJ

H
Ul
a

i
i
•x
M
i
UJ
a
a




































n
it
ii
n
u
n
i
n
n
n
n
n
n
n
n
n
n
ii
n
M
n
n
n
n
n
n
it
u
n
n
n
n
n
n
n
M
ir
n
n
n
it
n
n
u
I
H
n
II
n
it
II
n
u
n
II
n
it
n
II
ii
u
H
II
M
II
n
n
n
n
n
it
n
ii
n
n
u
n
n
n
it
n
n
n
M
n
it
i
i
i
i
I
i
n
n
it
n
u
M
u
it
it
n
ii
n
u
n
it
n
n
it
t
i
i
i
I
I
i
II
it
n
n
ii
n
it
n
ti
n
ti
n






















~r
X
3
t~

5-
f~

O
o

Ul
Kl































UJ
H-
to

2f

§
O
3
1

z
o
n
to
3
e
o
u

3J
z
cc
UJ
l-
X
UJ






1
1

UJ
M

N
UJ
a.
^.
t-
UJ
o
CE
8
to
>-
H


Q
u

a
UJ
OL















X
K

*»









































f
o
z
M

.
D.
O
O
U

U
£
1-
U
UJ
_J
UJ

(0
^t
^^
Ul



1
1-

8


UJ
K
M
to
UJ
E

Z

z
^
a.
j;
o
o
^
CO
N

O
N

O


1
1
UJ
y
5
3
to
CO
M

1-
l-l
E
a:
UJ
a.

u.
O

Ul
t-

o
















































t
UJ

g
O
(0

2
UJ
Z

^f
g
u.

1-
(J
«t
to

CO
M

CJ
M
1-

z
J~
n;
UJ
h-
UJ
a
^
CO
a-




i
i
a
3
i
i-

^_
to

u.
0

Ul
t-
<
o

o
UJ
t-
<
r:
M
t-

UJ




































































(?•
-£>
O-


g

t-
M
J^
C*
UJ
a.




















M
^
f^
in *^
1 ^

in o
^ X
i a

CM
^—i
tn


















z
o

C£
Ul
a.

}_-
a: u
UJ <
^: H
u z
o o
t£ O
u

si
—> ui
ID

^^















U >-
< o
z
en uj
< CD

in ta-
t—





>-
CO

UJ
o
<
i;

o
M
t-
•<
•z
T.
ci:
UJ
1-
UJ
O
1 10
1 >-l
i to
i -a.
II CO
i
i •»
n
n •
i •
t
ii
i
i
t
i

t
u
i
i
t
t

t
i
i
t
t
n
i
t
i
i
i
i
i
i
t

i
i
t
i
i

1 CO
1 I-
1 M

1 M
1 _J
1
I Z
1 O
1 M
1 CO
to
1 M
I E
1 UJ
II
1
1
II
! z
1 <
1 3
1 -1
1 -I
1 O
i a.
i
n
i
i
i
i
i
i
i h-
! 2
1 X
t 3
1 O
I D:
•x.
1 1-
t
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1 t-
1 O
I UJ
i ->
1 (0
1 3
1 CO
1
1 10
1 UJ
i to
t to
1 UJ
I O
I O
t a
1 OL
u.
u.
UJ

H
o
a.

t
•
•


§
M

^
u

u.
M
O
o
E

(/)
to
UJ
o
o
G?
a.

a
0

k_
z
UJ
x:
CL
M
*"^
CJ
UJ

_ J
o
OL

z
o
u











o
UJ
t-
1—
M
y
UJ








1-
t-l
U

a
o





















h-
M
D:
Ul
a.
to
n
X
t-
o

0
»- in *- t- i- t-
o • o u u o
< CM «t - £D 03 CO BJ
_J U _l _l _l _J

O O O O O
o o o o o
O O CO 0 O
M CJ O CM I-l
• • * * *
O O O O rH






O X CM
E O O O O
a. > z to u







-,-

3
5
£

o
o
tn
K)

























CK
UJ
_J
M
O
CO




z
LU
M
0
M
U.
U.
UJ

UJ
re
o
E

t
>-
n:
<(
D

O
U
UJ
to

UJ
X
h-

fy_
o
u.

X
o


o
z
^(


or

E
M
a.
a.

UJ

[_

O:
O
u.

s:
m
CO

UJ
a

to
UJ
M
O

UJ
M •
u to
u. to
U- >-
UJ -J

z z
o <
M
t- U
U M

-J c5
-J Z
o o
u o
UJ

CO 0
UJ H
M
CK UJ
uj 3
to a

z a
M Ul
tt
tO M
z a
O Ul
-1 Lt
U
>- 1-
u p

O
3 tO
>- <
3
to
M -J
O
-J a:
0 1-
i n: z
1 t- 0
z u
to o
tu u E
H- a
O E
Z CL 1-
a.
CO
to
o
a.
UJ
M


UJ

DC
UJ
o
o
-
   <
   UJ
   a;
          D:
          ut
          £0

          §
   cc
   o
   to
   <
           I
          CD
          UJ
          ID

-------
                                             APPENDIX  —  DETAILED  SOURCE  LISTING
                                                                                                                        05/22/1934
SOURCE TYPE/SIZE---
                            EXTERNAL COMBUSTION - WOOD  WASTE
COMPANY NAME/SITE LOCATION  ULTRASYSTEMS
                                                                                         BLUE  LAKE,  CA
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT NO. HAC-129
DETERMINATION HADE BY       NQRTH COAST  UNITED AQMO
                             (AGENCY)
                     CHUCK SASSENRATH
                  (AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE—  01/12/6'*
                                       ESTIMATED DATE OF START-UP—   1980
                                       <707)-4«-3093
                                           (FHONE)
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
4 BASIS
PCT EFF
BOILER, WOOD WASTE
                                    162.00 MH3TU/H
                                                           PM
                                                                     0.0450  LB/MMBTU
                                                                            MULTICLONE/GRANULAR  BED  ELECTO-SCRUBBER
                                                                                       99.20
NOTES 	
STATE FILE A320-029
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 126
                                                                                                      INITIAL  REVIEW   POST STARTUP
                                                                                        REVIEW STATUS:
                ID  NUMBER  CA-0077
                                                                     SO'J"CE TYPE  CODE

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE—
EXTERNAL COHBUSTION  - MULTIPLE FUELS
                                                                                             65.00 MW
COMPANY NAME/SITE LOCATION  AMES MUNICIPAL  POWER PLANT
                                                                                             AMES, IA
                                                                                                                      STORY  COUNTY
DETERMINATION IS BACT FOR A MODIFIED SOURCE.
PERMIT NO.
DETERMINATION MADE BY       EPA REGION VII
                             (AGENCY)
                              DANIEL RODRIGUEZ
                            (AGENCY CONTACT  PERSON)
                                       DATE OF PERMIT ISSUANCE—  11/05/79
                                       ESTIMATED DATE OF START-UP—
                                       <816)-374-6525
                                           (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
          THROUGHPUT
           CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
t BASIS
FCT EFF
BOILER, UNIT 88, STEAM GEN.
                                    769.00  MMBTU/H
                                                          PM         0.1000  LB/MMBTU
                                                                            HOT  SIDE  ESP'S
                                                          S02        1.2000  LB/KMBTU
                                                                            LOW  S  COAL
                                                          NOX        0.7000  LB/KMBTU
                                                                            BOILER DESIGN
                                                                                                 BACT
                                                                                                 99.60
                                                                                                 BACT

                                                                                                 BACT
NOTES 	
UPON STARTUP OF UNIT 8, S02 EMISSIONS FROM EXISTING  UNITS  5,6,  AND  7 WILL  BE  REDUCED  FROM PRE-MODIFICATION EMISSION LEVELS EEC
AUSE OF A PROJECTED VIOLATION OF THE 2<*HR S02/NAAQS.  SEE IO',JA CONSENT CRDER 79-A-007.  THE STACKS ON TWO EXISTING UNITS
AMD CM PROPOSED UNIT 8 ARE LESS THAN GEP STACK  HEIGHT.  UNIT  «8  WILL BE CAPABLE  OF  BURNING UP TO 30X REFUSE-DERIVED FUEL. TWO E
SP'S UILL BE INSTALLED, STACKED ONE ON TOP OF THE  OTHER BECAUSE OF  SPACE  LIMITATION.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 127
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW STATUS:   04/01/19S3
                          ID NUMBER IA-0006
                                                                               SOURCE TYPE CCDE
                                                                                                   1.5

-------
                                             APPENDIX  — DETAILED SOURCE  LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE---         EXTERNAL COMBUSTION -  MULTIPLE  FUELS                               90.00  MW


COMPANY NAME/SITE LOCATION  CITY OF COLUMBUS                                              COLUK8US,  OH
                                                                                                                   FRANKLIN COUNTY


DETERMINATION IS  B/L FOR A NEW SOURCE.                                                         DATE  OF PERMIT  ISSUANCE--  10/16/79
PERMIT NO. EPA-5-A-80-3                                                                        ESTIMATED  DATE  CF  START-UP-
DETERMINATION MADE BY       EPA REGION V                   BONIFACE  THAYIL                      (312J-6S6-6054
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT       POLLUTANT     EMISSION  LIMITS                                    ...  & BASIS
TO THIS PERMIT                         CAPACITY         EMITTED             CONTROL EQUIPMENT  OR  PROCESS  MODIFICATION  ...  FCT EFF


BOILER, REFUSE/COAL FIRED, 6 EA     240.00 MMBTU/H
                                                           PM         0.1000  LB/MMBTU
                                                           S02        0.9300  LB/MM3TU 6  BOILERS OPER.
                                                                     1.4400  LB/MI-!3TU,<4 BOILERS OPER.
                                                           NOX        0.5000  LB/IiMBTU
                                                                     0.7000  LB/M!!3TU COAL  ONLY


NOTES 	
REFUSE MUST COMPRISE AT LEAST SOX OF THE TOTAL HEAT  INPUT.













                                                                                                      INITIAL  REVIEW   POST  STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:   04/01/1933

PAGE G- 12S                                           ID NUMBER CH-0045                                    SOURCE TYPE CODE    1.5

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                         05/22/1934
SOURCE TYPE/SIZE—         EXTERNAL COMBUSTION - MULTIPLE FUELS                             3600.00 MMBTU/H


COMPANY NAME/SITE LOCATION  FLORIDA POWER & LIGHT                                           SANFORD, FL 32771
                            BARWICK ROAD                                                                             VOLUSIA COUNTY
                           __ ___„ __.__« <____»•• — .» — -.-. — —• — _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ — — _ •. _ _ H — .. w — « — ••. .__...__ _ _ — i« «. — ~ _ — ~ — _ —. — — ..^^ — _ — -. — «.«, — — ____..

DETERMINATION IS      FOR A MODIFIED SOURCE.                                                    DATE OF PERMIT ISSUANCE—  02/20/80
PERMIT NO. FL-047                                                                               ESTIMATED DATE OF START-UP—   1979
DETERMINATION MADE BY       FLORIDA DER                    ED PALAGYI                           (904)-<488-1344
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)

= = = = = = = = = = r; === = = = = = = = rz = = rs = = = = = r = = rrr = = = ; = : = = = r= = = = r = = = = = = 5 = = = = = r = = = = z = = = = = = r = = = = = = = === = = = 5=rr = = r ====r= = = = = = = ==r====r =====rr= = r =

PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ...» BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
_	__ — __ — ____ — — _-._*_-_ — —.___ — __ — »__ — — ___ — ___ — __ — ___ — _ — — _____ _ „__ — ••______«._-. — — _ — _^_ — _ —— _ ____ — ~ — —— — ___ —_ __».,_.-.•.__._-..- — — -.-. — — -. — — — -. — -. — -.—


COAL PULVERIZERS                  96000.00 LB/H
                                                           PM        7.7000 LB/H                                              NSPS
                                                                    11.0900 T/YR
                                                                            BAGHOUSE                                          99.96


NOTES 	
TEST FACILITY - 50/50 COAL/OIL FIRED UNIT.

TESTING COMPLETED, SOURCE NO LONGER EXISTS.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 129
                                                                                                       INITIAL REVIEW   POST  STARTUP
                                                                                          REVIEW STATUS:  04/01/19S3     01/25/1984
ID NUMBER FL-0014
                                                      SOURCE TYPE CCDE
                                                                          1.5

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/22/1984



SOURCE TYPE/SIZE—-         EXTERNAL COMBUSTION  - MULTIPLE FUELS                            4457.00 MMBTU/H


COMPANY NAME/SITE LOCATION  GULF STATES UTILITY                                          WEST LAKE, LA
                                                                                                                 CALCASIEU PARISH


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE—  07/24/81
PERMIT NO. (REGION FILE NO.) PSD-LA-305                                                       ESTIMATED DATE OF START-UP--
DETERMINATION MADE BY       EPA REGION VI                  JOHN BUNYAK                         (214J-767-1594
                             (AGENCY)                  (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT       POLLUTANT    EMISSION LIMITS                                   . . . & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
TURBINE
                                   1390.00  MMBTU/H
COAL GASIFIER
                                     75.34  T/H COAL
NOX


CO


SOS


PM



NOX

CO

S02

PM
0.2700 LB/MMBTU OIL
0.2700 LB/MM3TU GAS
       STEAM INJECTION
0.1300 LB/MMBTU OIL
0.0900 LB/MMBTU GAS
       EFFICIENT tCMBUSTION
0.6800 LB/MMBTU OIL
0.0010 LB/MMBTU GAS
       LOW SULFUR FUEL (.7X)
0.2100 LB/MMBTU OIL
0.0010 LB/MM9TU GAS
       EFFICIENT COMBUSTION (.5X ASH)

0.0300 LB/T
       EXISTING INTERNAL CONTROLS
0.6900 LB/T
       EXISTING INTERNAL CONTROLS
0.1000 LB/T
       EXISTING INTERNAL CONTROLS
0.0300 LB/T
       EXISTING INTERNAL CONTROLS
                                                                                                                            NSPS

                                                                                                                            60.00
                                                                                                                            BACT
BACT


BACT



BACT

BACT

BACT

BACT
PAGE G- 130

-------
(CONTINUED)  GULF  STATES UTILITY
PROCESSES SUBJECT
TO THIS PERMIT
BOILER












COAL GASIFIER








TURBINE








COAL DELIVERY


THROUGHPUT POLLUTANT
CAPACITY EMITTED
1706.00 MMBTU/H
NOX


CO


$02


P»


53.65 T/H COAL
NOX

CO

S02

PM

1361.00 MMBTU/H
NOX

CO

S02

PM


PM

EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

0.1900 LB/HMBTU COAL GAS
0.3000 LB/HK3TU OIL
LOW BTU COAL GAS AS FUEL
0.0080 LB/HK3TU COAL GAS
0.0300 LB/MfiBTU OIL
LOW BTU COAL GAS AS FUEL
0.6200 LB/MfSTU COAL GAS
0.6600 LB/MM3TU OIL
LOW BTU COAL GAS AS FUEL
0.0300 LB/t1"BTU COAL GAS
0.0100 LB/MM3TU OIL
LOW BTU COAL GAS AS FUEL

0.0100 LB/T
RECYCLE PROCESS GAS
0.0100 LB/T
EFFICIENT COMBUSTION
0.1900 LB/T
TAIL GAS FLARE
0.0100 LB/T
HONE

0.2500 LB/MMBTU
STEAM INJECTION
0.0900 LB/MK5TU
EFFICIENT COMBUSTION
0.2100 LB/MMSTU
LOW SULFUR FUEL ( .77.)
0.0010 LB/r,:.3TU
COAL GAS SLOW ASH FUEL (.5X)

0.0800 LB/H
WETTING
... 4 BASIS
... PCT EFF

BACT

56.00
BACT


BACT


BACT



BACT

BACT

BACT

BACT


NSPS

BACT

BACT

BACT


BACT

PAGE G- 131

-------
(CCOTINUEO) GULF STATES UTILITY
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
& BASIS
PCT EFF
CRUSHING/SCREENING
PULVERIZING
                                                           PM         0.1400  LB/H
                                                                            BAGHOUSE
                                                           PM
                               0.0800  LB/H
                                      BAGHOUSE
                                                                                                                             BACT
                                                                                                                             BACT
NOTES
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 132
                                                                                                     INITIAL REVIEW  POST STARTUP
                                                                                        REVIEW STATUS:   04/01/1=33
                ID NUMBER  LA-0004
                                                                     SOURCE  TYPE  CODE
                                                                                         1.5

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/19S4
SOURCE TYPE/SIZE---
                            EXTERNAL COMBUSTION  - MULTIPLE FUELS
                                                                                             442.00  MMBTU/H
COMPANY NAME/SITE LOCATION  HARNEY ELECT.
                                                                                             HINES,  OH
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT HO. (REGION FILE NO.) FSO-X81-12
DETERMINATION MADE BY       EPA REGION X
                             (AGENCY)
                     PAUL BOYS
                  (AGENCY CONTACT PERSON)
                                                         t'ATE OF PERMIT ISSUANCE--  08/14/81
                                                         ESTIMATED DATE OF START-UP--
                                           ( FHCN'E )
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
& BASIS
PCT EFF
BOILERS, Z
                                    221.00 MMBTU/H EA
                                                           S02       0.1800 L8/MMBTU
                                                                            DRY SCRUBBING
                                                           NOX       0.5000 LB/M;:BTU
                                                                            DRY COMBUSTION CONTROLS
                                                                                       BACT
                                                                                       65.00
                                                                                       BACT
NOTES
 (*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

 PAGE G- 133
                ID NUMBER OR-0001
                                                                INITIAL REVIEW   POST  STARTUP
                                                   REVIEW STATUS:  04/01/~
-------
                                             APPENDIX  —-  DETAILED  SOURCE  LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE—         EXTERNAL COMBUSTION - MULTIPLE  FUELS                              350.00  HP


COMPANY NAME/SITE LOCATION  INTERNATIONAL PAPER CO.                                                ,  TX
                                                                                                                     DALLAS COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                       DATE  OF  PERMIT  ISSUANCE--  02/04/84
PERMIT NO. 14163                                                                              ESTIMATED  DATE  OF  START-UP--   1984
DETERMINATION MADE BY       TEXAS ACS                      RANDY HAMILTON                     I 512>-451-5711
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT       POLLUTANT     EMISSION  LIMITS                                    .. .  & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT OR PROCESS  MODIFICATION  ...  PCT EFF


BOILER, PACKAGE                      14.60 MMBTU/H
                                                           P(1         0.0100  LB/MMBTU                                          BACT
                                                           VOC        O.OOCO  LB/MM3TU                                          BACT
                                                           NOX        0.1000  LB/MMBTU                                          BACT
                                                                            AUTOMATIC QZ CONTROL
                                                           S02        0.2200  LB/MJ3TU                                          BACT
                                                                            0.3X S IN OIL
                                                           CO         0.0300  LB/MMBTU                                          BACT


NOTES 	
EMISSION LIMITS ARE BASED ON OIL FIRING WHICH WAY BE USED AS BACK-UP. NATURAL  GAS WILL BE  PRIMARY FUEL. GAS  FIRIN3  EMISSIONS A
RE - NEGLIGIBLE FCR PM, SOS, VOC, AND CO, BUT 0.09 LB/MI13TU FOR NOX.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 134
                                                                                                     INITIAL REVIEW   POST STARTUP
                                                                                        REVIEW STATUS;
ID NUMBER TX-0144
                                                     SOURCE TYPE CODE
                                                                         1.5

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                         05/22/1934




SOURCE TYPE/SIZE—-         EXTERNAL COMBUSTION - MULTIPLE FUELS                             700.00 MM
                           	,	__«.._..—*.	_.	•	•	

COMPANY NAME/SITE LOCATION  POWER AUTHORITY STATE OF NEW YORK                               STATEN, NY
                           	__	„_„„_„__—__. —	___.„._—. — _...- — _.	„______ — — -... — -..- — — — *.	— — — — _«.- — — — — — — *. — — — •. — — — — — — — — — —— — — — — — — — — —

DETERMINATION IS BACT FOR A NEW SOURCE.                                                        OVTE 0F PERMIT  ISSUANCE--  02/22/82
PERMIT NO.                                                                                     ESTIMATED DATE  OF START-UP--   1937
DETERMINATION MADE BY       EPA REGION II                  DENNIS SANTELLA                     (£12>-264-9623
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHCME)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                    ... t BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ... PCT EFF
BOILER
                                   6700.00 MMBTU/H
AUX. BOILER
COAL HANDLING
                                    220.00 MMBTU/H
PM        0.0310 LB/MMBTU COAL
          0.0300 LB/MMBTU COAL/ROF
PM        0.0120 LB/MK3TU OIL
VE       20.0000 '/. OPACITY
S02       0.4000 LB/MM3TU
                 FGD
NOX       0.6000 LB/MKBTU COAL
          0.3000 LB/KM3TU OIL
                 GOOD CO:3'JSTION
CO        0.0410 LB/TOSTU
                 GCCD COtEUSTION

PM        0.0640 LB/MV3TU
                 GOOD COrSUSTION
S02       0.3000 '/. S FUEL
NOX       0.3000 LB/IC'.STU

COA»
                 USE OF  PRE-WASHED  COAL
                                                                                                                              BACT

                                                                                                                              BACT

                                                                                                                              BACT
                                                                                                                              92.00
                                                                                                                              BACT
                                                                                                                              BACT
                                                                                                                               SIP
                                                                                                                               BACT
 PAGE  G-  135

-------
(CONTINUED) POWER AUTHORITY STATE OF  NEW YORK
PROCESSES SUBJECT
TO THIS PERMIT
COAL CRUSHED
THROUGHPUT POLLUTANT
CAPACITY EMITTED
PM
VE
EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION
0.0300 GR/DSCF
20.0000 X OPACITY
... t BASIS
... PCT EFF
BACT
COOLINS TOWER
                                                          PM        0.0020 X OF H20 FLOW
                                                                           DRIFT ELIMINATOR



NOTES 	
CONTACT REGION 2 FOR DESIGN SPECIFICS FOR CONTROL DEVICES.
                                                                                                     INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:  CV01/19S3
PAGE G- 136                                           ID NUMBER NY-0005                                    SOURCE TYPE CCDE    1.5

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/198*



SOURCE TYPE/SIZE	         EXTERNAL COMBUSTION - MULTIPLE FUELS


COMPANY NAME/SITE LOCATION  STONE CONTAINER CORP.                                            HODGE, LA
                                                                                                                    JACKSON  PARISH


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT  ISSUANCE—  06/02/83
PERMIT NO. PSD-LA-505                                                                         ESTIMATED DATE  OF  START-UP—    198*
DETERMINATION MADE BY       LAQD/EPA REGION VI             BHARAT CONTRACTOR                   (5041-342-8940
                             (AGENCY)                  (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                    ... & BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF
BOILER, COAL FIRED
                                   1023.00 MMBTU/H
BOILER, COMBINATION, BARK/COAL *    680.40 MMBTU/H
                                                          S02    1227.6000 LB/H
                                                                    1.2000
PM      102.3000
          0.1000

NOX     716.1000
          0.7000

CO       47.6000
          0.0465

VOC      14.3000

BE        0.0006

F         0.8200

S02
                                                                           SIKGLE-ALKALI FGD
                                                                           LB/H
                                                                           LB/NMBTU
                                                                           ESP
                                                                           LB/H
                                                                           LB/MMBTU
                                                                           BOILER DESIGN
                                                                           LB/H
                                                                           LB/HMBTU
                                                                           BOILER DESIGN
                                                                           LB/H
                                                                           BOILER DESIGN
                                                                           LB/H
                                                                           EOILER DESIGN
                                                                           LB/H
                                                                  816.5000  LB/H
                                                                    1.2000  LB/KMBTU
                                                                            LOW S FUEL/STACK MONITOR
B/N

95.00
NSPS

99.00
B/N
BACT


BACT

BACT

BACT

B/N
PAGE G- 137

-------
                                                           PM       68.0000  LB/H
                                                                     0.1000  LB/MMBTU
                                                                            ESP
                                                           NOX      476.3000  LB/H
                                                                     0.7000  LB/MMBTU
                                                                            OVERFIRE AIR  COMPARTMENT
                                                           CO      4Z0.4000  LB/H
                                                                     0.6180  LB/MMBTU
                                                                            OVERFIRE AIR  COMPARTMENT
                                                           VOC      105.9000  LB/H
                                                                            OVERFIRE AIR  COMPARTMENT
                                                           BE        0.0003  LB/H
                                                                            OVERFIRE AIR  COMPARTMENT
                                                           F          3.7500  LB/H
                                                                       NSPS

                                                                       99.00
                                                                       B/N
                                                                       BACT


                                                                       BACT

                                                                       BACT

                                                                       BACT
NOTES 	
BASIA OF F LIMIT ON BOILER IS 100. PPM F IN COAL.
(«) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 133
                                                                                                      INITIAL REVIEW   POST  STARTUP
                                                                                        REVIEW STATUS:
ID NUMBER LA-0042
                                                     SCURCE TYPE CCDE
                                                                         1.5

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/22/1984



SOURCE TYPE/SIZE—         EXTERNAL COMBUSTION - OTHER                                   161000.00 LB/H


COMPANY NAME/SITE LOCATION  CALIFORNIA POWER & LIGHT                                     FIREBAUGH, CA

                           	

DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE--   01/01/6*
PERMIT NO. SJ 83-08                                                                           ESTIMATED DATE OF START-UP-    1936
DETERMINATION MADE BY       EPA REGION IX                 MATT HABER                          (415 )-974-8c09
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT         POLLUTANT    EMISSION  LIMITS                                    ••-  * BASIS
TO THIS PERMIT                         CAPACITY           EMITTED            CONTROL EQUIPMENT OR  PROCESS MODIFICATION   ...  FCT EFF
BOILER, 2 EA
                                  80500.00 LB/H  BIOMASS
                                                           S02       37.0000  LB/H
                                                                    40.0000  PPM AT  17.  02
                                                                            DRY SCRUBBER
                                                                            LIMIT ON FUEL S CONTENT IS 0.21 7..
                                                           NOX      140.0000  LB/H
                                                                            CONTROL OF OVERFIRE  4  UNDER FIRE AIR
                                                           CO      309.0000  LB/H
                                                                            PROPER  COMBUSTION
                                                           PM        0.0100  GR/DSCF
                                                                            BAGHOUSE
                                                                       89.00
THE TOTAL PLANT HAS A NET ELECTRICAL GENERATING CAPACITY OF APPROX.  50 MM.  ALL BACT IS DETERMINED BY TECH./ ECONOMICS. TSP LIM
IT IS DISTRICT LAER. CEM'S REQUIRED FOR NOX, S02, OPACITY.  FINAL NOX PPM LIMIT WILL BE SET
AFTER OPERATION COMMENCES.
 (*)  INDICATES DATUM WAS  TRUNCATED FOR THIS TABLE.

 PAGE G-  139
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW STATUS:  04/19/19S4
ID NUMBER CA-0062
                                                     SOURCE TYPE CODE
                                                                         1.6

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/19S4



SOURCE TYPE/SIZE	         EXTERNAL COMBUSTION - OTHER


COMPANY NAME/SITE LOCATION  CONTINENTAL CARBON CO.                                                ,  TX
                                                                                                                      MOORE COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE  OF PERMIT ISSUANCE—  11/04/82
PERMIT NO. C-9011                                                                              ESTIMATED DATE OF START-UP—   19S1
DETERMINATION MADE BY       TEXAS ACB                      JAMES  CROCKER                       (512)-451-5711
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ...  i BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ...  FCT EFF


WASTE GAS DRYER                      13.60 MMBTU/H
                                                           PM         3.2000  LB/H
                                                                            INCIN.  OF  CARBON BLACK IN C.  BLACK REACTOR
                                                           NOX        5.8000  LB/H
                                                           S02       69.1000  LB/H


NOTES 	
100X EFF. IN REDUCING REDUCED SULFUR COMPOUNDS « HYDROCARBONS,  A  CORRESPONDING INCREASE  IN SULFUR DIOXIDE EMISSIONS.














                                                                                                      INITIAL REVIEW   POST  STARTUP
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         K.,,iu,, S:«,^b:   o:, ;-,/19S4

PAGE G- 140                                           ID NUMBER TX-0124                                     SOURCE  TYPE CODE    1.6

-------
                                            APPENDIX -- DETAILED SOURCE LISTING
                                                                                                                        05/32/1984



SOURCE TYPE/SIZE-—         EXTERNAL COMBUSTION - OTHER                                     1500.00 MW
                           		________-._----	

COMPANY NAME/SITE LOCATION  HOUSTON LIGHTING & POWER                                        FARRAR, TX
                                                                                                                  LIMESTONE COUNTY
                           	

DETERMINATION IS BACT FOR A NEW SOURCE.                                                         DATE OF  PERMIT ISSUANCE—  09/10/81
PERMIT NO. (REGION FILE NO.) PSD-TX-371                                                         ESTIMATED  DATE OF  START-UP—   19S5
DETERMINATION MADE BY       EPA REGION VI                  JOHN BUNYAK                          (2141-767-1594
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHOHE )



PROCESSES SUBJECT                     THROUGHPUT         POLLUTANT     EMISSION  LIMITS                                    ... & BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS  MODIFICATION  ... PCT EFF
BOILER, LIGNITE-FIRED, 2 EA
                                   7863.00 MMBTU/H
LIMESTONE RAILCAR UNLOAD
PM        0.0300 LB/MMBTU
                 ELECTROSTATIC PRECIPITATOR
S02
                 FLUE GAS DESULFURIZATION
NOX       0.6000 LB/MMBTU
                 TAKGENTIAL FIRING, LOW NOX BURNER
CO        0.1100 LB/MMBTU
                 CONTROLLED COMB. 4 02 MON.
VOC       0.0010 LB/HM3TU
                 BOILER DESIGN
FB        o.oooo LB/TMBTU
                 FLUE GAS DESULFURIZATION
HG        0.0000 LE/M;:3TU
                 FLUE GAS DESULFURIZATION
BE        0.0000 LB/MI3TU
                 FLUE GAS DESULFURIZATICN
H2S*      0.0310 LB/tt;i3TU
                 MIST ELIMINATOR

PM        1.3300 LB/H
                 WET SUPPRESSION
                                                                                                                             NSPS
                                                                                                                             99.95

                                                                                                                             82.00
                                                                                                                             NSPS

                                                                                                                             BACT

                                                                                                                             BACT

                                                                                                                             BACT
                                                                                                                             93.00
                                                                                                                             BACT
                                                                                                                             13.00
                                                                                                                             BACT
                                                                                                                             99.40
                                                                                                                             BACT
                                                                                                                             BACT
PAGE G- 141

-------
(CONTINUED) HOUSTON LIGHTING & POWER
PROCESSES SUBJECT
TO THIS PERMIT
LIMESTONE RECLAIM & TRANSFER


LIMESTONE LOADOUT


LIMESTONE STORAGE PILE


LIMESTONE RECLAIM TUNNEL


LIMESTONE FEED SILO, 3 EA


FLY ASH SILO


FEED SILO, WASTE BLENDING


PUGMILL, WASTE BLENDING


THROUGHPUT POLLUTANT
CAPACITY EMITTED

PM


PM


PM


PM


PM


PM


PM


PM

EMISSION LIMITS
CONTROL EQUIPMENT OP PROCESS MODIFICATION

0.0500 LB/H
BAGHOUSE

0.0200 LB/H
BAGHOUSE

0.3700 LB/H
TELESCOPIC CHUTE

0.0200 LB/H
BAGHOUSE

0.0100 LB/H
BAGHOUSE

0.1200 LB/H
BAGHOUSE

0.1200 LB/H
BAGHOUSE

0.2100 LB/H
BAGHOUSE
...» BASIS
... PCT EFF

BACT
99.80

BACT
99.80

BACT


BACT
99.80

BACT
99.80

BACT
99.80

BACT
99.80

BACT
99.80
NOTES 	
PM LIMIT TO BE COMPUTED BY APPLICANT USING GRAPH DERIVED FROM NSPS (CONSIDER CONTROL EFFICIENCY AKD FUEL SULFUR CONTENT). SULF
UP 1C ACID MIST LIMIT APPLIES WHEN FIRING LIGNITE WITH UP TO 1.71 LB/M,'3TU.
OTHERWISE, 0.075 LE/MMBTU WHEN FIRING LIGNITE WITH tiCRE THAN 1.71 LB/MiBTU.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 142
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW STATUS:  -04/01/**i933
ID NUMBER TX-OOOS
                                                     SOURCE TYPE CCDE
                                                                          1.6

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/22/1984



SOURCE TYPE/SIZE---         EXTERNAL COMBUSTION - OTHER                                     2010.00 T/D


COMPANY NAME/SITE LOCATION  METROPOLITAN SERVICE DISTRICT                              OREGON CITY, OR


DETERMINATION IS  B/L FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE-
PERMIT NO.  03-2667                                                                            ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY       OREGON DEQ                     LLOYD KOSTOW                        (503)-229-5186
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    '(PHONE)



PROCESSES SUBJECT                    THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ...  &  BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ...  PCT  EFF
BOILERS, 3
2010.00 T/D
                                                          PM        0.0150 GR/DSCF
                                                                           BAGHOUSE
                                                          VOC       0.1200 LB/T
                                                                           GOOD COMBUSTION
                                                          S02       0.5730 LB/T
                                                                           DRY SCRUBBER
                                                          NOX       3.5800 LB/T
                                                          HG        0.0025 LB/T
                                                                           BAGHOUSE
                                                          CO        1.4300 LB/T
                                                                           GOOD COMBUSTION
                                                          PB        0.0075 LB/T
                                                                           BAGHOUSE
                                                          F         0.0170 LB/T
                                                                           DRY SCRUBBER
                                                          HCL       0.6690 LB/T
                                                                           DRY SCRUBBER
                                                          TET*      0.0000 LB/T
                                                                           BAGHOUSE
                                                                           GOOD COMBUSTION
                                                                                          LAER
                                                                                          99.90
                                                                                          BACT

                                                                                          BACT
                                                                                          80.00
                                                                                          BACT
                                                                                          BACT

                                                                                          BACT

                                                                                          BACT

                                                                                          BACT
                                                                                          70.00
                                                                                          BACT
                                                                                          90.00
                                                                                          BACT
(*) INDICATES DATUM WAS TRUNCATED FOR THIS  TABLE.

PAGE G- 143
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                        REVIEW  STATUS:   04/01/19S3
                   ID N'UI'BER OR-C003
                                                                        SOURCE TYPE CODE
                                                                                            1.6

-------
NOTES 	
THE FINAL PERMIT HAS NOT ISSUED BECAUSE APPLICATION WAS  WITHDRAWN  FOLLOWING DEFEAT OF THE PROJECT BY VOTE ON INITIATIVE.  LIMIT
 ARE BASED ON PROPOSED PERMIT.
                                                                                                      INITIAL REVIEW  POST STARTUP
<») INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:  04/01/1933
PAGE G- l
-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/22/1934
SOURCE TYPE/SIZE—
EXTERNAL COMBUSTION  - OTHER
                                                                                             80.00 MW
COMPANY NAME/SITE LOCATION  OCCIDENTAL  GEOTHERMAL - OXY 81
                                                                                                   CA
                                                                                                                       LAKE COUNTY
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT NO. NSR-4-4-1 NC-81-03
DETERMINATION MADE BY       EPA REGION IX
                             (AGENCY)
                              MATT HABER
                            (AGENCY CONTACT  PERSON)
                                       DATE OF PERMIT ISSUANCE--  05/10/82
                                       ESTIMATED DATE OF START-UP--
                                       (415)-974-8209
                                           (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
          THROUGHPUT
           CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
& BASIS
PCT EFF
POWER PLANT
                                     80.00  MM
                                                          H2S
                                         8.0000  LB/H
                                                STRETFORD PROC..H202 TREAT.,  DESIGN
                                                                                                                             99.00
NOTES
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 145
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW STATUS:   04/01/1983    04/04/1934
                          ID NUMBER CA-0034
                                                                               SOURCE TYPE COOE    1.6

-------
                                             APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE---         EXTERNAL COMBUSTION -  OTHER


COMPANY NAME/SITE LOCATION  PACIFIC GAS S ELECTRIC CO., GEYSERS UNI*                               , CA
                                                                                                                    SONOMA COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                       DATE OF PERMIT ISSUANCE—   07/27/62
PERMIT NO. (REGION FILE NO.) NSR-4-4-3 SSB-31-03                                              ESTIMATED DATE OF START-UP--
DETERMINATION MADE BY       EPA REGION IX                 MATT HABER                          (415J-974-82C9
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT       POLLUTANT    EMISSION  LIMITS                                    ... « B4SIS
TO THIS PERMIT                         CAPACITY         EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT  EFF


POWER PLANT                           2.00 MMLB/H  STEAM
                                                          H2S      10.4000 LB/H                                             BACT
                                                                           STRETFORD  PROCESS i CATALYST SYS


NOTES 	
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 146
                                                                                                      INITIAL REVIEW   POST STARTUP
                                                                                        REVIEW STATUS:   04/01/1S33     04/04/1934
ID NUMBER CA-OOC9
                                                     SC'JPCE TYPE CODE    1.6

-------
                                            APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                        05/22/198*
SOURCE TYPE/SIZE—         EXTERNAL COMBUSTION  - OTHER                                      1500.00  MW
                           	____ — _ __	«.___ — ..	______ — — ______ — _ — ,- — — _ — —.___..__ — — -. — — — — —.	«.-. — » — •__ — — — — — — »_ — — — — __ —_ — — _ — —— —___——


COMPANY NAME/SITE LOCATION  TEXAS UTILITIES SEN  CO.                                       FRANKLIN,  TX
                            TWIN OAKS STATION                                                                      ROBERTSON COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                         DATE  OF PERMIT ISSUANCE—  09/22/77
PERMIT NO. PSD-TX-32                                                                           ESTIMATED  DATE OF START-UP—
DETERMINATION MADE BY       EPA REGION VI                   JOHN  BUNYAK                          (214)-767-1594
                             (AGENCY)                   (AGENCY  CONTACT PERSON)                     (PHONE)




PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                    ... t BASIS
TO THIS PERMIT                         CAPACITY           EMITTED           CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ... PCT EFF



LIGNITE FIRED STEAM                1500.00  MW
                                                           S02       1.2000  LB/MMBTU
                                                                            FGD                                               71.90
                                                           PM        0.1000  LB/MMBTU
                                                                            ESP                                               99.50



NOTES 	
LIGNITE-FIRED
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 147
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW STATUS:  04/01/1933
ID NUMBER TX-0003
                                                     SOURCE TYPE CODE
                                                                          1.6

-------
                                             APPENDIX —  DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE—         EXTERNAL COMBUSTION - OTHER                                     1500.00 MW
                           — __^ — _—. —————___—___— — — — — — _____ — — — — — — — — — — _v— — — — — — — — — — — —— — —— — — — — — ——. — — — ——— — — ——— — —— — — ^-— — — ————————— — — — — — —— — —-.

COHPANY NAME/SITE LOCATION  TEXAS UTILITIES SERVICE,  INC.                                    KOSSE, TX 76653
                            OAK KNOLL STATION                                                                      LIMESTON COUNTY
                           --_- —		— _---_	— _ — ..-.---_-	_- — _--	___-_	

DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—  02/09/78
PERMIT NO. PSD-TX-47                                                                           ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY       EPA REGION VI                  JOHN BUNYAK                         (214 J-767-1594
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHCNE )



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   .. . & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
— — — — — — — — — — — — — -. — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —— — — — — — — — — — — — — — — — — — — —— «. —».—. — — — — — — — — — — — — — — — — — — — — — — —. — — — — — — — — — — — -. — — — — — — — — — — — — — — — — — — — — —

LIGNITE FIRED STEAM                1500.00 MW
                                                           SOZ       1.2000 LB/MMBTU
                                                                            FGD                                              74.00
                                                           PM        0.1000 LB/MMBTU
                                                                            ESP                                              90.00


NOTES 	
LIGNITE FIRED














                                                                                                      INITIAL REVIEW  POST STARTUP
(*> INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:  04/01/1933

PAGE G- 148                                           ID NUMBER TX-0002                                    SOURCE TYPE CODE    1.6

-------
                                            APPENDIX  — DETAILED  SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE—         EXTERNAL COMBUSTION -  OTHER                                       792.00 MKMBTU/H


COMPANY NAME/SITE LOCATION  TEXAS UTILITIES SERVICE, INC.                                 HENDERSON, TX
                            MILL CREEK                                                                                 RUSK COUNTY
                           —	_ —	_ — —	__	— — — — — — _ — — ,....--. — — — — — .- — — — — — — — — — — -. — — — — — — — — —	—, — — — — — — — — — — — -. — — — — — — — — — — — — — —— — —— —— — — — —.

DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—  01/17/78
PERMIT NO. PSD-TX-44                                                                           ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY       EPA REGION VI                 JOE WINKLER                         (214)-767-1594
                             (AGENCY)                  (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT       POLLUTANT     EMISSION LIMITS                                    ...» BASIS
TO THIS PERMIT                         CAPACITY         EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... FCT EFF
— — — — — — — — ™ — — — — — _ — • — — — __ — __ — •_•_•____ — •____ — «™— — ™_ —™__ —— ™ —— —™ —— — — — — — — — — — — — —.—— — — » — — — — — — — — — — — — — — — — — — • — — — — — — — — — — — — — — — — — — — — — — — —~~"*~ — ~~~™

LIGNITE FIRED STEAM ELECT.          750.00 MM
                                                          S02       1.2000 LB/MMBTU
                                                                            FGD                                              89.70
                                                           PM        0.1000 LB/MMBTU
                                                                            ESP                                              99.44


NOTES 	
EMISSIONS ARE BASED ON 1.06 LB/MMSTU S02, 0.1  LB/MMBTU PART., AND  0.6 LB/HR NOX. LOWER EMISSIONS MAY BE REQUIRED.

LIGNITE FIRED













                                                                                                      INITIAL REVIEW   POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         rLsitvi STATUS:  04/01/1933

PAGE G- 149                                           ID  f."J"!:C^ T'-'~:                                     C-'J'^E T>FE  CODE     1.6

-------
                                             APPENDIX -- DETAILED SOURCE LISTING
                                                                                                                        05/22/198*
                                                   	_.._	— — — —	—	— —	— — — —	—— ""S —— — = — — = = = — —— — — — = = ~ — = = = = = = = :==:::= — — :: =



SOURCE TYPE/SIZE—         EXTERNAL COMBUSTION - OTHER                                     2250.00 T/D
                           	___	___-_-	-	-	-	—	__-----__-. — — --	- — —	— _„___ — — — — __ —	- — --.-- —


COMPANY NAME/SITE LOCATION  WESTCHESTER COUNTY RESOURCE RECOVERY                         PECKSKILL, NY
                           ___	— ———— —	——— — ———	___..._.__— — — _..-.——————— —————— ————— — ————


DETERMINATION IS BACT FOR A NEW SOURCE.                                                                       o

DETERMINATION MADE BY       EPA REGION II                  BARRY TORNICK                       (212J-264-9579
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)

— — •— — — — — — — — — — » — — — — — 3 — — — — ~ S— — — — — Z —~~ —— Z — — US — — — — ~~ — ™ — ~ —— ~ —— — — 3 —— — — — IT—— — — ~ — — — — — — — IT — " — — "—. — — — — — — — ». — — — — — — ——^^ — — — — —— — — — — — — — — — — — — — — — — — — — — — —


PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
INCINERATORS, REFUSE FIRED, WAT*    750.00 T/D
                                                           PM        0.0300 GR/DSCF
                                                                            ESP
                                                                            AT 12X CO
                                                           CO        0.6200 LB/T REFUSE
                                                                            DESIGN, HIGH XS AIR, GOOD COMBUSTION
                                                           NOX       3.0000 LB/T REFUSE
                                                                            DESIGN, PROPER OPERATION
                                                           S02
                                                           PB        0.0300 GR/DSCF
                                                                            ESP
                                                                            AT 1£X CO
                                                           HG        0.0300 GS/DSCF
                                                                            ESP
                                                                            AT 12X CO
                                                           BE        0.0300 GR/DSCF
                                                                            ESP
                                                                            AT 12X CO
                                                           ASB*      0.0300 GR/DSCF
                                                                            ESP
                                                                            AT 12X CO
                                                                       BACT
                                                                       98.50

                                                                       BACT

                                                                       BACT

                                                                       BACT
                                                                       BACT
                                                                       93.50

                                                                       BACT
                                                                       93.50

                                                                       BACT
                                                                       93.50

                                                                       BACT
                                                                       98.50
 (*)  INDICATES DATUM WAS TRUNCATED  FOR  THIS TABLE.

 PAGE G-  150
                                                                                                       INITIAL  REVIEW  POST STARTUP
                                                                                         REVIEW  STATUS;   04/01/1053
ID NUMBER NY-0008
                                                     SOURCE TYPE CODE     1.6

-------
NOTES
                                                                                                      INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEW STATUS:   04/01/"i933

PAGE 6- 151                                           ID  NUMBER  NY-OOOS                                    SOURCE TYPE CODE    1.6

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE---         REFUSE INCINERATION


COMPANY NAME/SITE LOCATION  DUTCHESS COUNTY RESOURCE RECOVERY                         POUGHKEEPSIE, NY
                           __ »_«. _____ _.» — •__• — — — — — — — — — — —. — — -•— — — — — — — —.«• — — — — — — — — — ™_ — — — _ »_..«. — — — —.—..•. — — — •— — — — •. — ••• — — •- — « — — .-^..—. — — — «••• — — -. — — » — -• — -• — —

DETERHINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—  10/14/83
PERMIT NO. 134601 0024                                                                         ESTIMATED DATE OF START-UP—   1986
DETERMINATION MADE BY       NEW YORK DEC                   JAMES HARRINGTON                    (518)-457-2018
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    
-------
                                             APPEKDIX — DETAILED SOURCE LISTING
                                                                                                                         05/22/1984
SOURCE TYPE/SIZE—         REFUSE INCINERATION                                             1800.00 T/D RDF
                           — —,«___ —™ —___ — w —— — — — _ — — — — — —. — — — — -. — — — — — » — — — — — — —— — — -. — — — — — •— — — — — — — — — — — — — — — — — — — — — — — — — —~ — -- —— — —~— — — —-1"1 —— ~~~~ — ~-~"-

COMPANY NAME/SITE LOCATION  ENERGY ANSWERS CORP.                                         ROCHESTER, MA
                            SEMASS PROJECT


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—  03/15/82
PERMIT NO. 025-120MA14                                                                         ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY       EPA REGION I                   JOHN COURCIER                       (617J-223-4448
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (FKONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ...  & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ...  FCT EFF
— _-.- —	__.._	______..________,___,._.._____ — ___	____«_»____ — __-,___»-.__-.-._ — —. — _ — •, — _ — — — __ — — — — — — — — — — — — — — — — — — — ". — --—— — ---. — — — •--- — — -- — •• — — -- — — — — — — —

BOILER,MATER-COOLED, 3 EA.          600.00 T/D RDF EA
                                                           PM        0.0500 GR/DSCF 12X C02                                   BACT
                                                                            ESP.3-STAGE                                       96.00
                                                           S02       0.3400 LB/MMBTU                                          BACT
                                                                     0.3000 X S BY UT, OIL
                                                                            LOW S 82 FUEL OIL/LOW S RDF
                                                           NOX       0.5000 LB/MMBTU                                          BACT
                                                                            BOILER DESIGN


NOTES 	
ALL BACT LIMITS WERE DETERMINED SIMPLY BY TECHNOLOGY AVAILABLE AND THE ECONO NOMIC IMPACTS OF OTHER CONTROLS.











                                                                                                       INITIAL REVIEW  POST STARTUP
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:   04/01/1933

PAGE G- 153                                           ID NUMBER MA-0002                                     SOURCE  TYPE  CODE    2..1

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984
r:r = : = = rr = = = rr = = = = r = = = : = = r: = = = = r = = = rr== = = = = = = = rrrrrz=r: = r = : = = = = = r = = = = = = r = = = = = = = = = = = r = r = r = = = = = = = = z = = = = = = = = = : = = = = r = r = = r = = = r: = = r = = rr =



SOURCE TYPE/SIZE	         REFUSE INCINERATION                                             2360.00 T/D
                           — ______.. _______ «.______ _,,..______..______,._.-___ __ ».«____ — — — — — «- — — — i—— — — — — — — — — — — — ^-«- —— — — — — — — •--• — — — — • — «..«.— __ — — «. — — —

COMPANY NAME/SITE LOCATION  HOOKER ENERGY CORP.                                      NIAGARA FALLS, NY
                                                                                                                    NIAGARA COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE--  07/23/81
PERMIT NO. NONE                                                                                ESTIMATED DATE OF START-UP—   19S2
DETERMINATION MADE BY       EPA REGION II                  BARRY TORNICK                       (212)-264-9579
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHCNE )



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
RDF/COAL FIRED BOILERS
                                   2360.00 T/D REFUSE
                                                           S02       1.2000 LB/MMBTU COAL
                                                                     0.8000 LB/MMBTU OIL
                                                                            CONTRL METHOD: FUEL s CONTENT
                                                           HOX       0.7000 LB/MMBTU COAL
                                                                     0.3000 LB/MriBTU OIL
                                                                            CONTRL METHOD: TEMP t E.A.
                                                           PM        0.1000 LB/MMBTU COAL
                                                                     0.0700 LB/MMSTU OIL
                                                           PM        0.0300 GR/DSCF REFUSE
                                                           VE       20.0000 •/. OPACITY COAL
                                                                    20.0000 '/. OPACITY OIL
                                                           VE       20.0000 7. OPACITY REFUSE
                                                                       BACT

                                                                       BACT
NOTES 	
COAL USE LIMITED TO 30 DAYS PER YEAR. COMBUSTION FUEL EMISSION LIMITS INTERPOLATED BASED ON FUEL MIXTURE RATIO.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 154
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW STATUS:  04/01/1933
ID NUMBER NY-0002
                                                     SOURCE TYPE CODE
                                                                          2.1

-------
                                            APPENDIX -- DETAILED SOURCE LISTING
                                                                                                                       05/22/1984



SOURCE TYPE/SIZE—-         REFUSE  INCINERATION


COMPANY NAME/SITE LOCATION  KATY  SEGHERS                                                CLEARFIELD, UT


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—  02/24/84
PERMIT NO.                                                                                    ESTIMATED DATE OF START-UP--    1985
DETERMINATION MADE BY       UTAH  BAQ                       DAVID KOPTA                         (801J-533-6108
                             (AGEKCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    . . . i BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF
INCINERATOR & BOILER, WASTE HEAT    500.00  T/D
                                                          PM        0.0250 GR/DSCF AT 12X C02
                                                                           ESP
                                                          VE       20.0000 7. OPACITY
                                                                           ESP
                                                          S02      22.4000 LB/H
                                                                           LIME SCRUBBER/INJECTION
                                                          HCL      31.8000 LB/H
                                                                           LIME SCRUBBER/INJECTION
                                                          NOX      29.9000 LB/H
                                                                           COMBUSTION CONTROL
                                                          CO       35.5000 LB/H
                                                                           COMBUSTION CONTROL
                                                          F         1.1000 LB/H
                                                                           ESP
                                                          HG        0.1200 LB/H
                                                          PB        0.2200 LB/H
                                                                           ESP
                                    BACT
                                    98.00
                                    BACT

                                    BACT
                                    50.00
                                    BACT
                                    50.00
                                    BACT

                                    BACT

                                    BACT

                                    BACT
                                    BACT
NOTES
<*) INDICATES DATUM WAS TRUNCATED FOR THIS  TABLE.

PAGE G- 155
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS;
                                                      ID NUMBER UT-0032
                  SOURCE TYPE CODE
                                      2.1

-------
                                             APPENDIX  — DETAILED SOURCE  LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE	         REFUSE INCINERATION                                             1000.00 T/D


COMPANY NAME/SITE LOCATION  MCKAY BAY REFUSE-TO-ENERGY PROJECT                               TAMPA, FL 33602


DETERMINATION IS LAER FOR A NEW SOURCE.                                                        DATE OF PERMIT  ISSUANCE—   04/25/82
PERMIT NO. AC 29-47277                                                                        ESTIMATED DATE  OF  START-UP—    1984
DETERMINATION MADE BY       FLORIDA DER                    JOHN SVEC                           (904)-4S8-1344
                             (AGENCY)                  (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    . .. S BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF


MASS BURN FURNACES                 1000.00  T/D WASTE
                                                          PM        0.0250 GR/DSCF AT 12X 02                                LAER
                                                                           ESP                                              99.00
                                                          VE
                                                                           CONTINUOUS OPACITY MONITOR


NOTES 	
CONTINUOUS OPACITY MONITOR LIMITS TO BE  DETERMINED DURING PERFORMANCE TESTING. FACILITY TO INCLUDE WASTE HEAT  BOILERS ANDTURBI
NE ELECTRICAL GENERATORS.














                                                                                                     INITIAL  REVIEW  POST STARTUP
<*) INDICATES DATUM WAS TRUNCATED FOR THIS  TABLE.                                        REVIEW STATUS:  04/01/1983

PAGE G- 156                                           ID NUMBER FL-0030                                    SOURCE TYPE  CODE    2.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1934
SOURCE TYPE/SIZE —
                            REFUSE INCINERATION
                                                                                           1000.00 T/D
COMPANY NAME/SITE LOCATION  MCKAY BAY REFUSE-TO-ENERGY PROJECT
                                                       TAMPA,  FL 33602
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT NO. (REGION FILE NO.) PSD FL-086
DETERMINATION MADE BY       FLORIDA DER
                             t AGENCY)
                                                         DATE OF PERMIT ISSUANCE—  07/02/82
                                                         ESTIMATED DATE OF START-UP—
                     JOHN SVEC
                  (AGENCY CONTACT PERSON)
                                           ( PHCfJE )
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
& BASIS
PCT EFF
MASS BURN FURNACES
                                   1000.00  T/D WASTE
                                                          S02     170.0000  LB/H
                                                                            LOU SULFUR  FUEL
                                                          NOX     300.0000  LB/H
                                                                            COMBUSTION  TECHNIQUE
                                                          VOC        9.0000  LB/H
                                                                            COMBUSTION  TECHNIQUE
                                                          PB         3.1000  LB/H
                                                                            ESP
                                                          f          6.0000  LB/H
                                                                            NONE
                                                          HG         0.6000  LB/H
                                                                            ESP
                                                          BE         5.0000  G/D
                                                                            ESP
                                                                                       98.00
                                                                                       93.00
NOTES 	
FACILITY DESIGN ALLOWS FOR FUTURE INSTALLATION OF A SCRUBBER SYSTEM; NSPS APPLIES TO THIS  FACILITY.  FURNACES-FOUR 250 TPD USIN
G VOLUND TECHNOLOGY, WASTE HEAT BOILERS t TURBINE GENERATORS.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 157
                                                                INITIAL REVIEW  POST STARTUP
                                                   REVIEW STATUS:  04/01/1933
                                                      ID NUMBER FL-0030A
                                                                     SOURCE TYPE CODE    2.1

-------
                                              APPENDIX — DETAILED SOURCE LISTING
                                                                                                                           05/22/1984
SOURCE TYPE/SIZE---          REFUSE INCINERATION                                               600.00 T/D
                            — — — — — — — — — — .«..•. — — — — — .^—. — — .._•— —»-__• —•. — ___.— ___»_ — — —.—.» — — —. —— _ —— -,»_,.~ «.___»_,___„___ ._..__ — __ — — ____» — ___.»_._,...__ —•___—,


COMPANY NAME/SITE  LOCATION  MUNICIPAL INCINERATOR PULASKI HWY                             BALTIMORE, MD 21237
                             PULASKI HIGHWAY                                                                   BALTIMORE CITY COUNTY
                            —•— — — — •- — — — — — — — — — — — — — — — — — .. — — — __ — — — .»__ «..__«_ _ — ___ _n _ — ___ ,«..._• — ._•__ — ____„__., __.... „_..__.«____.. »«__..«.__.. __ — «. — __•,


DETERMINATION  IS BACT  FOR  A NEW SOURCE.                                                         DATE OF PERMIT  ISSUANCE—  01/25/80
PERMIT NO.  76MD-09                                                                              ESTIMATED DATE  OF START-UP--   1981
DETERMINATION  MADE BY        EPA REGION III                 ED VOLLBERG                          (215)-597-8990  •
                              (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)

u~~ ~~~~~ ~~ *~~" ~ zr~ — — — — — — — — — — — — — — — — — — — — — — — — -. — — — — •- — —— — — — — — -• — — — »- — — — — >.•-« — -._« — _»__«»«.____«___ -r — _. — — ^_ —-, — __ — .,___ «.___ — . _ _ _ «. — __«.« «. _-.___ —___•«.__
— — — — — — — — — — — — — — — -. — — .--.__ — -, — — _«- — _ — — _ — — — ___ — —____—____^ — ____-.__-.«,_______—,_____________ — _ — _„.______________„___ __ — •.____»___^_^___~~__~~~ —


PROCESSES SUBJECT                      THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... 4 BASIS
TO THIS PERMIT                          CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
MUNICIPAL INCINERATOR
                                     600.00 T/D MSW
                                                            PM        0.0300  GR/DSCF
                                                                     81.6000  T/YR
                                                                              ESP
                                                            S02      35.1000  PFH
                                                                    154.0000  T/YR
                                                                              PROPER  COMBUSTION TECHNIQUES
                                                            CO       30.0000  PFH
                                                                    127.0000  T/YR
                                                                              PROPER  COMBUSTION TECHNIQUES
                                                            VOC       1.3000  PPH
                                                                      5.5000  T/YR
                                                                              PROPER  COMBUSTION TECHNIQUES
                                                            NOX       2.6000  FFH
                                                                     11.4000  T/YR
                                                                              PROPER  COMBUSTION TECHNIQUES
                                     SIP

                                     93.00
                                     BACT
                                     BACT


                                     BACT


                                     BACT
NOTES
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 158
             INITIAL  REVIEW  POST STARTUP
REVIEW STATUS;   04/01/1933
                                                       ID NUMBER MO-OC02
                                                                                                             SOURCE TYPE  CODE
                                                                                                                                  2.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1934



SOURCE TYPE/SIZE—         REFUSE  INCINERATION                                               62.50 T/H WASTE


COMPANY NAME/SITE LOCATION  NESWC RESOURCE RECOVERY FACILITY                         NORTH ANDOVER, MA


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT  ISSUANCE--  05/27/82
PERMIT NO. 029-121MA16                                                                        ESTIMATED DATE  OF START-UP--    1983
DETERMINATION MADE BY       EPA REGION I                   JOHN COURCIER                       (617)-223-4448
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                    THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... *  BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
STEAM GENERATING UNITS, 2 INCIN*
750.00 T/D  EA,  WAS*
AUXILIARY BOILER, 1
 19.60 MMBTU/H
PM        0.0500 GR/DSCF AT 12X C02
                 ESP
S02       0.3400 LB/MMBTU
                 LOU S FUEL - 0.3X S »2 OIL
NOX       0.3200 LB/MMBTU
                 INCINERATOR DESIGN
CO        0.0700 LB/MMBTU
                 INCINERATOR DESIGN
SOX       0.0200 LB/r.MBTU
                 INCINERATOR DESIGN

NOX       0.1550 LB/MMBTU
                 BOILER DESIGN
co        0.0350 LB/MMBTU
                 BOILER DESIGN
SOX       0.0200 LB/MM3TU
                 BOILER DESIGN
PM        o.iooo LB/t;;;sTU
S02       0.3400 LB/MM3TU
                 LOW S FUEL - 0.3/C S 32 OIL
                                                                                                                             B/S
                                                                                                                             98.66
                                                                                                                             BACT

                                                                                                                             BACT

                                                                                                                             BACT
                                                                                                                             98.00
                                                                                                                             BACT
                                                                                                                             BACT

                                                                                                                             BACT
                                                                                                                             98.00
                                                                                                                             BACT

                                                                                                                             B/S
                                                                                                                             BACT
(*) INDICATES DATUM WAS TRUNCATED FOR  THIS  TABLE.

PAGE G- 159
                                                                  INITIAL REVIEW  POST STARTUP
                                                     REVIEW STATUS:  04/01/1933
                                                     ID NUMBER MA-0004
                                                                       SOURCE TYPE CODE
                                                                                           2.1

-------
NOTES 	
LIMITS ARE REDUCTION OVER AP-4Z EMISSIONS
                                                                                                      INITIAL  PEVIEW   POST  STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:   04/01/1 <>33
PAGE G- 160                                           ID NUMBER MA-0004                                     SOURCE  TYPE  CCDE

-------
                                            APPENDIX ~ DETAILED SOURCE LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE — -
                            REFUSE  INCINERATION
                                                                                           2010.00 T/D 3 UNITS
COMPANY NAME/SITE LOCATION  N.E.  MARYLAND WASTE DISPOSAL AUTHORITY
                            1801  OLD  ANNAPOLIS ROAD
                                 BALTIMORE, MD 21230
                                                                                                            BALTIMORE  CITY  COUNTY
DETERMINATION IS BACT FOR A MODIFIED  SOURCE.
PERMIT NO. 81MD01
DETERMINATION MADE BY       EPA REGION  III
                             (AGENCY)
   BOB BLASZCZAK
(AGENCY CONTACT PERSON)
DATE OF PERMIT ISSUANCE—  09/10/81
ESTIMATED DATE OF START-UP--
(215)-597-8ie6
    (PHONE)
PROCESSES SUBJECT THROUGHPUT
TO THIS PERMIT CAPACITY
WATER WALL, 3 EA INCINERATOR 2010.00 T/D








POLLUTANT
EMITTED

S02

CO

NOX

F

EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

335.0000 LB/H
1259.0000 T/YR
109.0000 LB/H
406.0000 T/YR
227.0000 LB/H
999.0000 T/YR
4.2000 LB/H
15.7000 T/YR
... t BASIS
. . . PCT EFF

BACT

BACT

BACT

BACT

NOTES 	
MARYLAND DEPT.  OF HEALTH AND MENTAL HYGIENE PERFORMED  LAER ANALYSIS FOR PARTICULATE MATTER.  0.019 GR/OSCF  CORRECTED  TO \Z7. CO
IS BEING CONSIDERED (ESP).
EMISSION RATES BASED ON REFUSE CHARACTERISTICS. PERMITTEE IS TO PROVIDE PROCEDURES TO  ENSURE ACCEPTABLE  WASTE  BEFORE OPERATION
(») INDICATES DATUM WAS TRUNCATED FOR  THIS  TABLE.

PAGE G- 161
                                              INITIAL REVIEW  POST STARTUP
                                 REVIEW STATUS;  04/01/1033
                                                     ID
                                                               N3-3CC
                                                                                                           SO'JRCE  TYPE  CODE
                                                                                                                               2.1

-------
                                             APPENDIX  --  DETAILED  SOURCE  LISTING
                                                                                                                        05/32/1984
SOLRCE TYPE/SIZE-—         REFUSE INCINERATION                                              100.00  T/D SOLID WASTE
                           	•	

COMPANY NAME/SITE LOCATION  REDDY CREEK IMPROVEMENT  DIST                           LAKE  BUENA VISTA,  FL 32830
                            P.O. BOX 36                                                                              ORANGE COUNTY
                           	.	•	

DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE  OF PERMIT ISSUANCE—  02/11/81
PERMIT NO. PSD-FL-044                                                                          ESTIMATED DATE OF START-UP--   1932
DETERMINATION MADE BY       FLORIDA DER                    ED  PALAGYI                           1904)-4SS-13
-------
                                             APPENDIX  — DETAILED SOURCE  LISTING
                                                                                                                        05/22/1934
r = = = = = rrr = z = = rr = rs = = = = = = = = = = z = r=rr = = rrr = = = = = =: = r = = r = = i:r = = = - = = = r = = r = = = r = = ==r^ = =: = r = r = rr = rr = = = = = = = = = =: = = = = = = = = = = = = = = =: = === = == = = = = = = = = = = =


SOURCE TYPE/SIZE	         REFUSE INCINERATION                                               960.00 T/D RDF
                           	_.__	— — — — _ — .._-...—	»_ —*» —•.— .•».—, — — .. — — -••- — — — — — — — — — — — —	— — — — — —	— « — — «. — — — — — — — — — — — — -.*.— — —.— — — — — — —

COMPANY NAME/SITE LOCATION  REFUSE FUELS,  INC.                                             LAWRENCE, MA


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE OF PERMIT ISSUANCE—  03/23/81
PERMIT NO. 023-121MA12                                                                         ESTIMATED DATE OF START-UP—   1982
DETERMINATION MADE BY       EPA REGION I                  JOHN COURCIER                        (617)-223-4448
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT         POLLUTANT     EMISSION LIMITS                                    ... * BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF
FURNACE,WATER WALL, BALANCED DR«
                                    960.00 T/D RDF
                                                           PM        0.0250 GR/DSCF
                                                                            ESP,5-FIELD,IN SERIES
                                                           S         1.0000 '/. S OIL
                                                                     1.2000 LB/MM3TU RDF
                                                                            LOW S So OIL/LOW S RDF
                                                           NOX       0.7000 LB/MN3TU RDF
                                                                     0.3000 L6/MMBTU OIL
                                                                            BOILER DESIGN
                                                                        LAER
                                                                        93.00
                                                                        BACT
                                                                        BACT
NOTES 	
LAER REQUIRED ON TSP FOR NONATTAINMENT AREA IN LAWENCE. BACT ON S02 DETERMINED BY TECHNOLOGY AND ECONOMICS.  BACT  ON N02  DETERM
IHED BY MEETING NSPS LIMITS F03 FOSSIL FUEL BOLIERS.
1.2 LB/HJ-13TU EQUIV. TO 1.0 7. S OIL.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 163
                                                                                                       INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW STATUS'-   04/01/1983
ID NUMBER MA-0001
                                                      SOURCE  TYPE  CODE
                                                                          2.1

-------
                                             APPENDIX  — DETAILED  SOURCE  LISTING
                                                                                                                        05/22/1984
=—=z===—=======—================"==—=======" === ===—==="= —=—^


SOURCE TYPE/SIZE—         REFUSE INCINERATION                                               75.00 T/D 2 EA
                           	____„„	--.	---—---—-—-	__ — __- — — — __-_- — — - — - — -	— --------	_-. — __ —-.-__--	— - —	— — — —	

COMPANY NAME/SITE LOCATION  RESOURCES AUTHORITY                                           SALLATIN, TN                      „„,„.„.„
                                                                                                                     SUMMER COUNTY
                           	

DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE-  08/01/80
PERMIT NO                                                                                      ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY       TENNESSEE APCD                 MERVAT  AHMED                         (6151-741-3651
                             (AGENCY)                   (AGENCY CONTACT  PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION LIMITS                                   • • - * BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
	

BOILERS, 2 MUNICIPAL REFUSE BUR*     75.00 T/D EA
                                                           PM        0.0400 GR/SCF                                           NSPS
                                                                           SCRUB, t FABRIC FILTERS                          99.00



NOTES 	
 (*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

 PAGE G- 164
ID NUMBER TN-0012
                                                INITIAL REVIEW  POST STARTUP
                                   REVIEW STATUS;  04/01/1933
                                                     SOURCE TYPE CODE    2.1

-------
                                            APPEKDIX — DETAILED SOURCE  LISTING
                                                                                                                        05/22/198*



SOURCE TYPE/SIZE—         REFUSE INCINERATION
                           •»_«.»~ •.____«._ — _.... — _ __ — —— _*..._ __ _ _,._ __«_ _._ — __ __ ~__ ^»ww«««««v — — __ww^__».«._..».__» —_.. — — .... — — -•«. — — — — — — -•. — ••• — — — — — •— —

COMPANY NAME/SITE LOCATION  STEAM SUPPLY  CORP.                                                TULSA,  OK
                           	.	;	.	—	— — --	—	—	

DETERMINATION IS BACT FOR A NEW SOURCE.                                                         DATE  OF PERMIT ISSUANCE—  12/16/82
PERMIT NO. T82-90                                                                              ESTIMATED DATE OF START-UP—   1965
DETERMINATION MADE BY       TULSA CITY-COUNTY HEALTH DEPT   JIM  VAN SANDT                        (918)-744-1000
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION LIMITS                                   ... & BASIS
TO THIS PERMIT                        CAPACITY          EMITTED             CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF


INCINERATORS, SOLID WASTE, 3 EA     230.00 T/D
                                                           PM       31.7000  LB/H
                                                                            3 ESP'S, SEE  NOTE 82                             98.00
                                                           SOS      17.5000  LB/H
                                                           NOX      46.0000  LB/H
                                                           VOC        3.5000  LB/H
                                                           CO       54.6000  LB/H
                                                           HG         0.2000  LB/H


NOTES 	
RATES ARE TOTAL EMISSIONS. DSIC CODES 4931 & 4961  ARE  ALSO INVOLVED  BECAUSE STEAM t ELECTRICITY WILL BE SOLO TO INDUSTRY.

2) PERFORMANCE STANDARDS OF 10X AVG. OPACITY  (PER  CLOCK HOUR)  8 0.06  GR/DSCF CORRECTED  TO 12X CO HAVE BEEN IMPOSED.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 165
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW STATUS:  04/01/1933
ID NUMBER OK-0013
                                                     SCU-CE TYPE CODE
                                                                          2.1

-------
                                             APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                        05/22/1984




SOURCE TYPE/SIZE	         REFUSE INCINERATION                                              624.00  T/D


COMPANY NAME/SITE LOCATION  TRANS ENERGY                                                   BROOKS,  OR


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE  OF PERMIT  ISSUANCE—  12/19/83
PERMIT NO. 24-5398                                                                            ESTIMATED  DATE  OF  START-UP—    19S7
DETERMINATION MADE BY       OREGON DEQ                    WENDY SIMS                          (S03)-229-5259
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



PPOCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ...  & BASIS
TO THIS PERMIT                         CAPACITY         EMITTED             CONTROL EQUIPMENT OR  PROCESS  MODIFICATION  ...  PCT EFF
INCINERATOR, SOLID WASTE, 2 EA
                                    312.00 T/D
                                                           PM        0.0300  GR/DSCF  AT \Z'/. C02
                                                                    61.0000  T/YR
                                                                            BAGHOUSE,  OR  ESP
                                                           NOX      94.0000  LB/H
                                                                   290.0000  T/YR
                                                                            EQUIPMENT  DESIGN & OPERATION
                                                           HCL      23.0000  LB/'H
                                                                    69.0000  T/YR
                                                                            SCRUBBER
                                                           S02      73.0000  LB/H
                                                                   220.0000  T/YR
                                                                            EQUIPMENT  DESIGN 4 OPERATION
                                                           VE       10.0000  •/. OPACITY  SEE NOTE
                                                           CO       55.0000  LB/H
                                                                   170.0000  T/YR
                                                                            EQUIPMENT  DESIGN * OPERATION
                                                           HS        0.1700  LB/H
                                                                     0.5100  T/YR
                                                                            EQUIPMENT  DESIGN « OPERATION
                                                           VOC       3.1000  LB/H
                                                                     9.6000  T/YR
                                                                            EQUIPMENT  DESIGN 8, OPERATION
80.00
PAGE G- 166

-------
                                                           PB        0.5200 LB/H
                                                                     1.6000 T/YR
                                                                            EQUIPMENT DESIGN  * OPERATION
                                                           FLU*      1.6000 LB/H
                                                                     4.8000 T/YR
                                                                            EQUIPMENT DESIGN  * OPERATION
NOTES 	
NOT TO BE EXCEEDED FOR MORE THAN 3 MINUTES IN ANY ONE HOUR PERIOD.
                                                                                                       T'.'TTT1L PTVIEM  POST  STARTUP
<*) INDICATES DATUM WAS TRUNCATED  FOR THIS TABLE.                                         K..J.:.., b.AlLS:  04/19/1984
PAGE G- 167                                           ID NlT"Cn>  C"-000*                                     SC'J"CE TYPE CODE     2.1

-------
                                             APPENDIX —  DETAILED  SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE-—         SEWAGE SLUDGE INCINERATION
                           	•	

COMPANY NAME/SITE LOCATION  CITY OF L.A., HYPERION,  BUREAU OF ENGIN*                    LOS ANGLES, CA
                            CITY HALL
                           	_	_	— — —	—	•- —	—	—	—	—	—	—	— —	—	—	— — —

DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE--  09/30/62
PERMIT NO. (REGION FILE NO.) NSR-4-4-9 LA-82-02                                                ESTIMATED DATE OF START-UP--
DETERMINATION MADE BY       EPA REGION IX                  RICK SUGAREK                        <415J-974-3224
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION LIMITS                                   ... & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
_.. _____ ____..___--_____ — — _»-—. _____•• — __ — .i»_ —— — — .. — — — — ~ — •,__»• — __ — — — — — — -. — — — .- -. — _ — —. — —. — — — — — — — __•.«.___ — __ — _— — — _ _ — ______ ____ — ___ — __ — — — _• — __ — — — ,.-.—

GAS TURBINE, 4, DIGESTER GAS FI*      8.00 MW EA
                                                           S02      20.0000 PPM DRY BASIS                                    BACT
                                                                            WET SCRUBBER                                     90.00
THERMAL PROCESSING WASTE HEAT R*
                                                           S02      20.0000 PFM DRY BASIS                                    BACT
                                                                     9.2000 LB/H
                                                                            2 STAGE WET SCRUBBER/VENTU3I SCRUB
                                                                            COUNTER CURRENT TRAY TOWER
                                                           HG        0.2890 LB/H                                             BACT
                                                                            2 STAGE WET SCRUCBER
                                                           BE        0.0000 LB/H                                             BACT
                                                                            FABRIC FILTER/2 STAGE WET SCRUBBER


NOTES 	








                                                                                                      INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:  0PE CCDE    2.2

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/22/1984
SOURCE TYPE/SIZE—-
                            SEWAGE  SLUDGE INCINERATION
                                                                                            360.00 T/D SLUDGE
COMPANY NAME/SITE LOCATION  COUNTY  SANITATION DISTRICTS OF L.A. COU*
                                                                                           CARSON, CA
                                                                                                               LOS ANGELES COUNTY
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT NO. LA 83-02
DETERMINATION MADE BY       EPA REGION  IX
                             (AGENCY)
                     JOE  SLAMOVICH
                  (AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE—  02/13/84
                                       ESTIMATED DATE OF START-UP—
                                       (4151-974-8235
                                           (FHOS'E)
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
& BASIS
PCT EFF
COMBUSTOR, FLUIDIZED
                                     68.17 MMBTU/H
                                                          S02
                               0.0600 LB/MM3TU
                                      LIMESTONE INJECTION/SFRAY DRYER
                                                                                                                             99.00
NOTES
 <*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

 PAGE G- 169
                                                                                                      INITIAL P^VIEW  POST STARTUP
                                                                                         REVIEW STATUS:
                ID NUMBER CA-0033A
                                                                     SOURCE TKPE CODE    2.2

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984
==================================================================================================================================


SOURCE TYPE/SIZE—         OTHER SOLID WASTE DISPOSAL
                           _. __.___•_ ____________» — — — — — — — — — .—.-_ _ — — ™» —— — — -. — — — — — — — — — — -._ — — — — •—..— — — •- — — — — «- — — — — — — — — —-. — __ — -» — _ — — ..«* — — — — •- — — __•___

COMPANY NAME/SITE LOCATION  CREMATION SERVICES, INC.                                     CLEVELAND, OH 44113
                            1612 LEONARD ST.
                           	—	•	

DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE--
PEPMIT NO. 13-1217                                                                             ESTIMATED DATE OF START-UP--
DETERMINATION MADE BY       CLEVELAND DAPC                 IKE HABIB                           (216 1-664-3503
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (FHCNE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... & BASIS
TO THIS PEPMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT 05 PROCESS MODIFICATION  ... FCT  EFF
	

INCINERATOR, PATHOLOGICAL WASTE     800.00 LB/H
                                                           PM        0.5800 T/YR
                                                           VE        0.0000 '/. OPACITY
                                                           ODOR             NONE


NOTES		-
INCINERATOR BURN BODIES & INFECTIOUS WASTE FROM HOSPITALS.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PA3E G- 170
ID NUMBER OH-0055
                                                INITIAL REVIEW  POST STARTUP
                                   REVIEU STATUS;
                                                     SOURCE TYPE CODE    2.3

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/22/1984



SOURCE TYPE/SIZE	         OTHER  SOLID WASTE DISPOSAL


COMPANY NAME/SITE LOCATION  DELAWARE  SOLID WASTE AUTHORITY                              WILMINGTON, DE
                                                                                                                NEW CASTLE COUNTY


DETERMINATION IS BACT FOR A HEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—   03/14/80
PERMIT NO. 79DE02                                                                             ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY       EPA REGION  III                 BOB BLASZCZAK                       (215J-597-8186
                             (AGENCY)                  (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                    THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                    ...  &  BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS MODIFICATION   ...  PCT EFF
AIR CLASSIFIER


AIR CLASSIFIER

DUST CONTROL SYS

GLASS RECOVERY

AIR KNIFE

SECONDARY AIR CLASSIFER

DRYER
     PM        7.7000 LB/H
                      BAGHOUSE

     PM        7.7000 LB/H

     PM        5.2000 LB/H

     PM        6.2000 LB/H

     PM        3.8000 LB/H

     PM        4.1000 LB/H

     PM       12.8000 LB/H
BACT
99.90

BACT

BACT

BACT

BACT

BACT

BACT
NOTES
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 171
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW STATUS;   04/01/1933
ID
          DE-0003
                                                     SOURCE TYPE CODE
                                                                         2.3

-------
                                              APPENDIX — DETAILED  SOURCE LISTING
                                                                                                                         05/22/1984
= = = = = = = = r=rr = = = = = = = = = = = = r = = r = = = = = = = = = = s = = = = = = = = = = r = = r = = = = r = = = sr = = = r = = = r = = = = = = r = = = r = = = = = = = = = = = = r = = = = = r = = = = = rr = = = = = = = = = r = = = = = = r = = = = =


SOURCE TYPE/SIZE	         OTHER SOLID WASTE DISPOSAL
                           — »• — — — —— — — — — — -• — — — — "- — — — — — — — — — .— — — — — — — — — .— — — — — — — — — _ — — ___.-____.._______.__ __»-•-___..___..._,. — — ___.•...___.. ___«._ —_____*»

COMPANY NAME/SITE LOCATION  DELAWARE SOLID WASTE II                                      WILMINGTON, DE
                                                                                                                  NEW CASTLE COUNTY
                           •— — — •-— — — — — — — — — — — — — — — —•- — — — — — — — _ — — — -._ — — — — _ — — ___.,__.._-___•,____ — _»._____ ___ —— _______..__..________________».___.B,-,

DETERMINATION IS EACT FOR A MODIFIED SOURCE.                                                    DATE OF PERMIT ISSUANCE—  03/14/80
PERMIT NO. 79DE02 II                                                                            ESTIMATED DATE CF START-UP--
DETERMINATION MADE BY       EPA REGION III                 BOB BLASZCZAK                       (215)-597-81S6
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (FHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION LIMITS                                   .. . fc BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
DRYER

DRYER

BOILER

BOILER

HEATER

VENTS, 3
PM

PM

PM

PM

PM

PM
0.4800 LB/H

1.0400 LB/H

0.0100 LB/H

0.0200 LB/H

0.0010 LB/H

1.6000 LB/H
BACT

BACT

BACT

BACT

BACT

BACT
NOTES
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 172
                                            INITIAL REVIEW  POST STARTUP
                              REVIEW STATUS:   04/01/1933
                                                      ID NUMBER DE-0003A
                                                                                                            SCITCCE TYPE CODE
                                                                                                                                2.3

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/22/1984
SOURCE TYPE/SIZE—
                            OTHER  SOLID WASTE DISPOSAL
                                                                                        2880000.00 GAL
COMPANY NAME/SITE LOCATION  LUBBOCK  FEEOLOTS, INC.
                                                                                                  , TX
                                                                                                                    LUBBCCK  COUNTY
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT NO.  X-4142
DETERMINATION MADE BY       TEXAS ACB
                             (AGENCY)
     RALPH  BOWLER
  (AGENCY CONTACT  PERSON)
DATE OF PERMIT ISSUANCE—  02/16/83
ESTIMATED DATE OF START-UP-
IS^ )-451-5711
    (PHCHE)
PROCESSES SUBJECT THROUGHPUT POLLUTANT E
TO THIS PERMIT CAPACITY EMITTED
LOADING DIGESTERS, 12 EA 240000.00 G4L
ODCR
COLLECTING GAS, 12 EA 240000.00 GAL
ODOR
: — = = r — — = = = = = r = = r — — = = = — — = =r — — = = = = = ::_ = = = — = = = = = — = = =r =
EMISSION LIMITS ... & BASIS
- CONTROL EQUIPMENT OR PROCESS MODIFICATION . . . PCT EFF
SEE NOTE
EMPTYING DIGESTERS, 12 EA
                                 240000.00  GAL
                                                          ODOR
                      H2S COLLECT.  IN FE SPOUNGE & PIPED TO CUSTOMER.

                      SEE NOTE
NOTES 	
PROCESSES MANURE FROM A CATTLE FEEDLOT.

NOTE — SHOULD BE THE SAME AS EXISTINS FEEDLOT ODORS.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 173
ID NUMBER TX-0119
                                                INITIAL REVIEW  POST STARTUP
                                   REVIEW STATUS;  05/04/1934
                                                     SOURCE TYPE CODE    2.3

-------
•^ 1
CO i

rH
N i
CM 1
CM t
X 1

O 1
1
1

1
i
1
1
1
1

,
I

1
1
t

1



















g
M
t-

M
_J

UJ
U



in

o
UJ
_J
M
1-
UJ
O

|
1

X

D
Z
UJ
C.
C-

















































1
1



1
1
1 UJ
1 |-
i in
i <
l 3
i
1 00
1
1 1— t
l O
l O
t ^
1
1 D
l \
1 H
I
1 O
i O
1 '
1 O
1 "fr
1 vJ1
1 M
I
t
1
\
I
1
t
1
1
1
1
t
1
1
1
1
1
I
1
1
1

I
1
I
1
1
1
1
1
1


1
1
1
1 -J
I <
> in
1 O
i a.
i to
1 M
1 O
1
i uj
i t—
i (/>
i <
i 3
i
1 O
1 M
I -J
l 0
I CO
1
i a
1 UJ
I ^C.
I h-
I O
l
1
l
l
i
l
i
l
l
l l
l i
l i
1 UJ
H N
11 M
II (O
1 \
II UJ
ii a.
n >-
n \-
n
n UJ
II O
ii D:
II ID
II O
M U)



























•«(
U

7,
0
H
O
Z
M
5
H
3


































*
U
2


*
CO
55

^-
13
a
UJ

UJ
2
o
in
h-

3


2
O


^
U
o


UJ
^
rH
in
x
UJ
i:

2

^_
2

a
j:
o
u
O 1
CO 1
X
K)
0 1
X 1
rH
O 1
1
a.
i 3
i i
UJ t—
o n:
2 <
< 1—
3 I/)
in
in u.
M 0

H- uj o
M t- t\l
31 «C OJ
a: o co —
UJ 1 UJ
a Q -a- z
iu r- o
u. >- o- X
o < _i_ a
uj M in
H 1— rH

O UJ s-














2
O
in
a
UJ
a.

^
u

a: r-
UJ Z
^ o
< o
CO

CO O
O 2
CO UJ
in

«-^














>:
-
3 i o o
o r>- uj 2
in t^ u: uj
U
3 < < <
uj _i a —
2 _^ uj

*f *
o
a: 2
o
U. UJ

a M >~
UJ U. CD

— i 7: uj
O 0
10 rH <
M 13 3Z
UJ
2 D: 2
O — O
rH M
1- - 1-
< O <
222

r i- £
tt rH CC
UJ 3~ UJ
r- Ct r-
UJ uj UJ
o a. o
in u.
1 rH U.
i in uj

CO r-
1 0
i « a.
i
i • •
i « •
i • •
i
i
1 2
l 0
1 M
1 1-
1 <
1 U
1 t-4
1 U.
1 rH
1 0
1 O
1 H
1
i in
i in
1 UJ
i 8
i n:
i a.
i
1 Ct
l O
1
1 1-
1 2
1 UJ
1 ZZ
1 tL
1 M
1 Z3
i a
1 UJ
i in
i i- -i
1 M O
i r a:
1 M 1—
1 -1 2
1 0
1 2 0
1 O
1 M
i in
in
1 rH
1 E
1 UJ
1
1
1
1
i ^-
1 2 0
1 •< UJ
! i5t
1 _J rH
i -i r:
1 O UJ
1 O.
1
1
1
1

1
1
1
1 1-
1 O >-
1 D. r-
1 X rH
1 IB U
1 ID <
i o a.
i a: <
1 X O
i i-
i
i
i
i
i
i
n
n
n
n
ii
u
n
n
n
n
n
n
n
n
n
ii t-
II U
II UJ
n -> I'-
ll CO rH
ii 5 r
ii in a:
II UJ
n in a.
II UJ
n in in
II I/I M
1 UJ X
1 U t-
1 O
1 CK O
1 0. r-
o o
D; ce o CK in
UJ UJ • UJ •
< < o < o
_j — J ^ ^
CO «£>






g S C
2 (n a













0
X
1-
o
C3
«
O
•^

rH


*
_J
UJ
23
U_
X
UJ
^—
CO

3

*«
^

f~
in

rH
§

•
2
UJ
12

i:
^
UJ
1-
in
                                                        .
                                                      3 •*
                                                      h- CO
                                                      £E O-
                                                      < in
                                                      V- X
                                                      in -t
                                                       in -.T
                                                       O o
                                                       ti-
ll  CM
II
II  O
II  U
                                                      3
                                                      UJ Kt
                                                      M CO
                                                      > O-
                                                        l O
                                                          X
                                                              II   UJ
                                                              II   to-
ll  UJ
II  U
 i  o:
 I  Z>
 I  O
 I  in
                                                          VI

                                                          3
                                                               II  O
                                                               n   i
                                                               n  <
                                                               n  U
                                                               n
                                                               II  CK
                                                               II  UJ
                                                               II  CO
                                                               ii  r
                                                               II  D
                                                               ii  2
                                                               II
                                                               II  O
                                                               II  M
                                                           CO
                                                           in
                                                           n
                                                           •s.
                                                           a.
                                                           o
                                                           o
                                                           UJ
                                                           l-
                                                           <
                                                           <
                                                           <
                                                           Q
in
UJ

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE—         NATURAL GAS TURBINES                                              26.00 MW


COMPANY NAME/SITE LOCATION  CHUGACH ELECTRIC ASSOCIATION, UNIT 84                     BERNICE LAKE, AK
                           _ _______ _ — _« .. ___ ________—. — -.— — — — — — — — — — —— — _~-~__ ___ ___» _«_ ___ _ w ___ .».._•___•-••— — — — — ••• — —— — — _ —— —• — — _.....•. — _ » —-.— ___ —

DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   CATE OF PERMIT ISSUANCE—  08/06/82
PERMIT NO. (REGION FILE NO.) PSD-X82-07                                                        ESTIMATED DATE OF START-UP—   1982
DETERMINATION MADE BY       EPA REGION X                   PAUL BOYS                           (206)-442-1567
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHCHE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION LIMITS                                    ... t BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
GAS TURBINE
                                     26.00  MW
                                                          NOX      130.0000  LB/H
                                                                   569.0000  T/YR
                                                                            WATER  INJECTION
                                                          PM        12.0000  LB/H
                                                                    48.2000  T/YR
                                                                            LCW S  COAL,DISTILLATE OIL BACKUP
NOTES 	
THE BACT NOX EMISSION LIMIT WAS BASED ON THE NSPS.  THE  BACT PM EMISSION WAS BASED ON THE USE OF *2 DISTILLATE OIL, HOWEVER, TH
E COMPANY PLANS TO USE NATURAL GAS AS THE PRIMARY FUEL.  BECAUSE OF  LIMITED  BACKUP CAPACITY AT THAT LOCATION,
THE COMPANY REQUESTED A PERMIT BASED ON 100X OIL USE.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 175
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW STATUS:  04/01/1933
ID NUMBER AK-0005
                                                     SOURCE TYPE CODE
                                                                         3.1

-------
                                             APPENDIX —  DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE-—         NATURAL GAS TURBINES


COMPANY NAME/SITE LOCATION  COLORADO INTERSTATE GAS                                   LAKE STATION,  KS
                                                                                                                     KEARNY COUNTY


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE  OF PERMIT ISSUANCE—  10/19/83
PERMIT NO.                                                                                     ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY       EPA REGION VII                 STEVE  KOVAC                         (816)-374-6525
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT       POLLUTANT    EMISSION LIMITS                                   ... t BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ... PCT EFF


I.C. RECIP. ENGINES, GAS-FIRED,*   1475.00 HP EA
                                                           NOX     760.0000  PPMV .15X 02,  DRY BASIS
                                                                            OPERATE AT MAX EFFICIENCY


NOTES		
(*> INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 176
                                                INITIAL REVIEW  POST STARTUP
                                       Ehi SiATL'S:  0^/01/1933
ID NUMBER KS-0013
                                                     SOIKCE TYPE CODE    3.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/2C/19S4
SOURCE TYPE/SIZE—         NATURAL  GAS  TURBINES


COMPANY NAME/SITE LOCATION  CROWN ZELLERBACH, INC.                                         ANTIOCH, CA


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—  03/01/83
PERMIT NO. 28179                                                                              ESTIMATED DATE OF START-UP—    1933
DETERMINATION MADE BY       BAY AREA AQMD                  DOUG WOLF                           (415)-771-6000
                             (AGEMCY)                  (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... 8 BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   . .. PCT EFF


GAS TURBINE                          32.00 MW
                                                          NOX      42.0000 PPM N02 AT 157. 02
                                                                           WATER/STEAM INJECTION
DUCT BURNER                         145.00 MMBTU/H
                                                          NOX      88.0000 PPM N02 AT 3X 02
                                                                           LO-NOX DESIGN


NOTES 	
BURNING NATURAL GAS














                                                                                                     INITIAL REVIEW   POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:  04/01/1933

PAGE G- 177                                           ID NUMBER CA-0044                                     SCUSCE  TYPE CODE     3.1

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1934



SOURCE TYPE/SIZE	         NATURAL GAS TURBINES


COMPANY NAME/SITE LOCATION  DOW CHEMICAL, USA                                           PLAQUEMINE, LA
                                                                                                                  IBERVILLE PARISH


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE--  11/14/83
PERMIT NO. PSD-LA-393.M-1                                                                      ESTIMATED DATE OF START-UP--
DETERfUNATION MADE BY       LAQD/EPA REGION VI             BHARAT CONTRACTOR                   (504 J-342-8940
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF
_^__________^™_ — ^^__^_____ — ™_ — ____ — —_™^~ —— _ — _____ — — — — — — -- — _-- — — — — — — — — — — — —• — •— — — — — — — — — — — — -. — -•-- — -• — — — — — — — — — — —•--*--• — — — — — — — — — —• — •-• — — — ~ —— — — — — — — -*•-

TURBINE, 8GT-300 * GT-400, Z EA     100.00 MW
                                                           NOX    1194.0000 LB/H                                             N/A
                                                                            COMB. CONTRL
                                                           CO       66.0000 LB/H
                                                           VE        0.0000 •/. OPACITY


NOTES 	
THE ORIGINAL PERMIT PSD-LA-393 WAS ISSUED ON 08/11/81. SUBSEQUENT REVISION TO NSPS BY EPA ON 01/27/82 , 40CFR60, SUBPART GG, E
XEMPTEO THESE TURBINES FROM STEAM INJECTION CONTROLS.
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 178
                                                                                                      INITIAL P^VIEW  POST STARTUP
                                                                                         REVIEW STATUS:
ID NUMBER LA-0011A
                                                     SOURCE TYPE CODE
                                                                          3.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE—-         NATURAL GAS TURBINES                                             300.00 MM


COMPANY NAME/SITE LOCATION  GETTY OIL,  KERN  RIVER COGENERATION PROJ*                               , CA
                                                                                                                       KERN COUNTY
                           — — — — ____ — _-_ — ™^,»_____ —__«.„_____—. — *.____ — — — — — _____ — — — — __— — — — — — — — — — — ——. — — — — — — —. — — — — — — — — — — — —^ —— — — — — — — — — — — — ~ —— —

DETERMINATION IS BACT FOR A NEW SOURCE.                                                       DATE OF PERMIT ISSUANCE—  11/03/83
PERMIT NO. SJ 83-03                                                                           ESTIMATED DATE OF START-UP—   1934
DETERMINATION MADE BY       EPA REGION  IX                 MATT HABER                          (415J-974-S209
                             (AGENCY)                    (AGENCY CONTACT  PERSON)                    (PHONE )



PROCESSES SUBJECT                     THROUGHPUT         POLLUTANT    EMISSION LIMITS                                    ...  * BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ...  PCT EFF


TURBINE, GAS FIRED, 4 EA            825.00 MMBTU/H
                                                          CO        9.0000 PPM
                                                                   17.0000 LB/H
                                                                           PROPER COMBUSTION


NOTES 	
1.) EACH TURBINE IS LIMITED TO NOX EMISSION  OF 42 PPM &  140  LB/H BY A  LOCAL NSR PERMIT. 2.)  THE SOURCE HAS APPLIED  FOR  A MAJOR
 MODIFICATION TO INCREASE THE CO LIMIT  WHEN  FIRING  ON DISTILLATE FUEL, THE STAND-BY FUEL.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 179
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS;  04/19/1934
                                                      ID NUMBER CA-0063
                                                                                                           SOURCE TYPE CODE    3.1

-------
                                             APPENDIX  — DETAILED SOURCE  LISTING
                                                                                                                        05/22/1934



SOURCE TYPE/SIZE — -         NATURAL GAS TUPBINES


COMPANY NAME/SITE LOCATION  KISSIMMEE UTILITIES                                         KISSIMMEE,  FL


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE  OF  PERMIT  ISSUANCE—  03/30/84
PERMIT NO. AC 49-74656                                                                         ESTIMATED  DATE  OF START-UP—    1934
DETERMINATION MADE BY       FLORIDA DER                   TERESA HERON                         <904)-463-1344
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHC»E)



PROCESSES SUBJECT                     THROL'SHPUT        POLLUTANT     EMISSION  LIMITS                                    ... &  BASIS
TO THIS PERMIT                         CAPACITY         EMITTED             CONTROL EQUIPMENT  OR PROCESS  MODIFICATION   ... PCT EFF


TURBINE, GAS                        400.00 MHBTU/H
                                                          NOX       79.0000  PPM GAS FIRED
                                                                   129.0000  PPM OIL FIRED
                                                                            WATER  INJECTION                                  40.00
                                                          so2        o.sooo  LB/M:;STU
                                                                            FUEL S CONTENT
                                                          VE        20.0000  •/.  OPACITY  MAX
BOILER, WASTE HEAT                   41.70 HMBTU/H
                                                          S02        0.5000  LB/MMBTU
                                                                            FUEL S CONTENT


NOTES 	
NSPS SUSPART GG APPLICABLE. TURBINE EXHAUST GASES DISCHARGE  INTO A  WASTE  HEAT  BOILER.  TOTAL ELECTRIC POWER  GENERATED BY THE SY
STEM IS 50 GROSS MEGAWATTS.









                                                                                                      INITIAL  REVIEW  POST STARTUP
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                 _   _  REVIEW STATUS:

PAGE G- 160                                           ID NUMBER FL-0029A                                    SOURCE  TYPE CODE     3.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE-—         NATURAL  GAS TURBINES                                              73.50 MW


COMPANY NAME/SITE LOCATION  NEVADA PWR CO., CLARK STATION UNIT »7                   EAST  LAS VEGAS, NV


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF  PERMIT ISSUANCE—  10/01/79
PERMIT NO. (REGION FILE NO.) NV 78-02                                                         ESTIMATED  DATE OF START-UP—   1980
DETERMINATION MADE BY       EPA REGION IX                  JIM HANSON                          (415)-974-8038
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                    THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                    ...& BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS  MODIFICATION  ...  PCT EFF


GEN., GAS TURBINE                    73.50 MW
                                                          NOX       0.3<+00 LB/MMBTU
                                                                           WATER  INJECTION
                                                          PM        0.0300 LB/MflBTU
                                                          CO        0.1200 LB/Mt-fBTU
                                                          S02
                                                                           0.25X  S FUEL  CONTENT


NOTES 	
REGENERATOR IS SUBJECT TO NSPS.













                                                                                                      INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEW STATUS:  04/01/1983    02/13/19S4

PAGE G- 181                                 •         ID NUMBER NV-0003                                     SOURCE TYPE CODE    3.1

-------
                                             APPENDIX -- DETAILED SOURCE  LISTING
                                                                                                                        05/22/1934
SOURCE TYPE/SIZE- —
                            NATURAL GAS TURBINES
                                                                                             73.50 MW
COMPANY NAME/SITE LOCATION  NEVADA PWR CO.,  CLARK  STATION UNIT #8
                                                                                   EAST  LAS VEGAS, NV
DETERMINATION IS BACT FOR A MODIFIED SOURCE.
PERMIT HO.  (REGION FILE NO.) NV 60-01
DETERMINATION MADE BY       EPA REGION IX
                             (AGENCY)
                     LARRY  BOWERMAN
                  (AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE—  09/11/80
                                       ESTIMATED DATE OF START-UP—   1982
                                       (
-------
                                            APPENDIX ~ DETAILED SOURCE LISTING
                                                                                                                       05/22/1984
SOURCE TYPE/SIZE	         NATURAL GAS TURBINES


COMPANY NAME/SITE LOCATION  NORTHERN NATURAL GAS                                        CUNNINGHAM, KS
DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   OATE OF  PERMIT  ISSUANCE—   03/12/82
PERMIT NO.                                                                                     ESTIMATED DATE  OF  START-UP-
DETERMINATION MADE BY       EPA REGION VII                 STEVE KOVAC                         (816 )-37<+-6525
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)
PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ...  & BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS  MODIFICATION  ...  PCT EFF


I.C. RECIP. ENGINES,  DUAL FUEL,*    2250.00 HP EA
                                                          NOX      60.0000 LB/H
                                                          CO       15.0000 LB/H
                                                          VOC       3.9000 LB/H


NOTES 	
IN CONSIDERATION OF TEST RESULTS,  THE  CO  EMISSION LIMIT WAS CHANGED FROM 9 TO 15 LB/H ON NOV. 29,  1982.
                                                                                                      INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED  FOR  THIS TABLE.                                        REVIEW  STATUS:   04/01/1933
PAGE G- 183                                          ID NUMBER KS-0015                                     SOURCE TYPE CODE    3.1

-------
                                             APPENDIX --  DETAILED  SOURCE LISTING
                                                                                                                         05/22/1984



SOURCE TYPE/SIZE---         NATURAL GAS TURBINES


COMPANY NAME/SITE LOCATION  PANHANDLE EAST.  PIPELINE  CO.                            ELKHART STATION, KS
                                                                                                                     MORTON COUNTY


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE OF PERMIT ISSUANCE—   11/18/81
PERMIT NO.                                                                                     ESTIMATED DATE OF START-UP--
DETERMINATION MADE BY       EPA REGION VII                 STEVE KOVAC                         (816 )-374-6525
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION LIMITS                                    ... & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT  EFF
_..___ __..___ —. — — — „ .... _ _______» _______ -,_•______—_,.^..-____..__. — __ — ___ — — — _.- — — — — — — ___ — — -. — __ — — — ™ — — — — ~ — — — _™_..— -.»_—_ — — •.—— — _ — — — — ___ — — — — -._-. — — «. — —

I.C. RECIP. ENGINES, GAS FIRED,*   3200.00 HP EA
                                                           NOX     600.0000 PPMV 15X 02, DRY BASIS
                                                                            PRE-IGNITION CHAMBER


NOTES 	
(#) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- l£
-------
                                             APPENDIX —  DETAILED SOURCE LISTING
                                                                                                                         05/22/1984



SOURCE TYPE/SIZE---         NATURAL GAS TURBINES


COMPANY NAME/SITE LOCATION  PETRO-TEX CHEMICAL  CORP.                                                . TX
                                                                                                                      HARRIS COUNTY
                           — _ — — ....-. — — .,	„ —	.» —	«,— __.._ — _ — .. — — », — — — — — — — — — — _.. — .... — — — — — .» — — — — — — -•. — — — — — — — — — — — — — "- — — — — — — — — — — — — — — — —	— — — -. — — —

DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—  12/21/82
PERMIT NO. SEE NOTE                                                                            ESTIMATED DATE OF  START-UP--   1983
DETERMINATION MADE BY       TEXAS ACB                      JIMMY RANDALL                       (512(-451-5711
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT       POLLUTANT    EMISSION LIMITS                                    ... & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF


TURBINE, GAS                        982.30 MSCFH
                                                           NOX     237.9000 LB/H                                              NSPS
                                                                            H20 INJECTION
                                                           S02       0.7000 LB/H
                                                           CO       15.2500 LB/H                                              TECH


NOTES 	
NOTE — PERMIT NUMBER 9199, 9200. EACH PERMIT COVERS ONE  TURBINE.














                                                                                                       TMTJTSL PCVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        -'L..L,J  S.ATUS:   05/04/1934

PAGE G- 185                                           ID  NJI.jLK  i,-.--^..'                                     o_ ~t  lire CODE    3.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/198A
SOURCE TYPE/SIZE—-         NATURAL GAS TUPBINES                                             217.00 MMBTU/H


COMPANY NAME/SITE LOCATION  PROCTOR &  GAMBLE                                            SACRAMENTO, CA


DETERMINATION IS                                                                              DATE OF PERMIT ISSUANCE—   05/10/83
PERMIT NO. SAC 83-01                                                                          ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY       EPA REGION IX
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



FPOCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF
TURBINE. GAS
                                    217.00 MKBTU/H
BURNER, DUCT
     S02       0.3000 X S BY WT
     NOX      75.0000 PPM AT 15X 02, OIL
              62.0000 PPM AT 15X 02, GAS
                      H20 INJECTION
     CO       32.0000 LB/H GAS FIRED
              22.0000 LB/H OIL FIRED

     NOX       0:1500 LB/MMBTU
                      LOW NOX BURNERS
     CO        0.5000 LB/H
NOTES
(*> INDICATES DATUM WAS TRUNCATED FOR  THIS  TABLE.

PAGE G- 186
                                                                                                     INITIAL REVIEW  POST STARTUP
                                                                                        REVIEW STATUS;
ID NUMBER CA-0067
                                                     SOURCE TYPE CODE
                                                                         3.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/22/1984
SOURCE TYPE/SIZE---
                            NATURAL GAS TURBINES
                                                                                            303.00 NHP
COMPANY NAME/SITE LOCATION  PRUDHOE BAY CONSORTIUM
                                                 PRUDHOE BAY,  AK
DETERMINATION IS BACT FOR A MODIFIED SOURCE.
PERMIT NO.  (REGION FILE NO.) PSO-X81-01
DETERMINATION HADE BY       EPA REGION X
                             (AGENCY)
                                                         CATE OF PERMIT ISSUANCE—  09/29/81
                                                         ESTIMATED DATE OF START-UP--
                     DAVID  TETTA
                  (AGENCY CONTACT PERSON)
                                           ( PHONE )
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
4 BASIS
PCT EFF
TURBINES
HEATERS
                                    303.00 MHP
                                    250.00 MMBTU/H
                     NOX     150.0000 PPM
                                      DRY CONTROLS
                     CO        1.0900 LB/MMSCF FUEL
                                      PROPER COMBUSTION

                     NOX       0.0800 LB/MMBTU
                                      LOW NOX BURNERS
                     CO        0.0100 LB/MMBTU
                                      PROPER COMBUSTION
                                                                     BACT

                                                                     BACT


                                                                     BACT

                                                                     BACT
NOTES
(*) INDICATES DATUM WAS TRUNCATED  FOR THIS TABLE.

PAGE G- 187
                                                                INITIAL VVIEW  POST STARTUP
                                                   REVIEW STATUS:  04/01/19S3
                                                     ID NUMBER AK-0004
                                                                     SOURCE TYPE CCDE
                                                                                         3.1

-------
                                             APPENDIX -- DETAILED SOURCE  LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE-—         NATURAL GAS TURBINES                                              200.00 MM


COMPANY NAME/SITE LOCATION  PUGET SOUND POWER fc LIGHT                                     FREDONIA, HA


DETERMINATION IS BACT FOR A NEW SOURCE.                                                       DATE OF  PERMIT  ISSUANCE—  08/23/82
PERMIT NO. PSD-X-82-09                                                                        ESTIMATED DATE  OF  START-UP—    1984
DETERMINATION MADE BY       EPA REGION X                  PAUL BOYS                           (206J-442-1567
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHONE )



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... 8  BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... FCT EFF
GAS TURBINE, 2
100.00 MW EA
                                                          NOX     480.0000 LB/H
                                                                 2061.OCOO T/YR
                                                                           WATER INJECTION
                                                          CO      185.0000 LB/H
                                                                  645.0000 T/YR
                                                          S02     640.0000 LB/H
                                                                  154.0000 T/YR
                                                          PM        2.9000 LB/H
                                                                   12.5000 T/YR


NOTES 	
THE NSPS LIMIT FOR NOX WAS THE BASIS FOR BACT. THE S02 BACT LIMIT WAS BASED ON THE USE OF 0.5X S OIL.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS  TABLE.

PAGE 6- 1S8
                                                                                                     INITIAL REVIEW   POST STARTUP
                                                                                        REVIEW STATUS;  04/01/1933
                 ID NUMBER WA-0007
                                                                       SOURCE  TYPE  CODE
                                                                                           3.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/22/1984
= = = : = = = = = = = r = = = = = = = = r = = = = = = = = = = = = = = = = = = = = = r = = = = = = = = = = = = r = = = = = = = = = = = ===r = = = r = = = = == = = = = = = = = = = = = = = = r = = = = = = r = = = = = = ==r = = = = r = = = = = r = = :r = =


SOURCE TYPE/SIZE---         NATURAL GAS TURBINES                                            1290.00 MW TOTAL


COMPANY NAME/SITE LOCATION  SOUTHERN CALIF. EDISON CO.                                            , CA
                            UPPER JOHNSON VALLEY                                                             SAN BERNARDINO COUNTY


DETERMINATION IS BACT                                                                         DATE OF PERMIT ISSUANCE—  04/25/63
PERMIT NO. SE 81-01                                                                           ESTIMATED DATE OF START-UP—
DETERMINATION MADE BY       EPA REGION IX                  MATT HABER                          (415 )-974-8209
                             CAGENCY)                   (AGENCY CONTACT PERSON)                    (PHOHE)



PROCESSES SUBJECT                    THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   .. . t BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... FCT  EFF
GAS TURBINE, 20
                                     64.50 MW EA
                                                          S02       0.0960 LB/MMBTU
                                                                   71.4500 LB/H/TUEBINE
                                                                           USE OF VERY LOW SULFUR (0.1X) OIL
                                                          NOX      44.5000 FFM
                                                                  140.0000 LB/H/TURBINE
                                                                           WATER INJECTION
                                                          CO       17.0000 LB/H/TURBINE
                                                                           PROPER COflBUSTION
                                                          PB        1.8000 FFM FUEL CONTENT
                                                          H2S*      0.1000 SULFUR FUEL OIL
                                                          ASB*      2.8500 LB/H/TURBINE
                                                                           CCMPL. H/TSP LIM. 10 LB/H.& SEMI-ANN. FUEL SAM*
                                                          HG        2.8500 LB/H/TUK5INE
                                                                           COMPL. W/TSP LIM. 10 LB/H.4 SEMI-ANN. FUEL SAM*


NOTES 	
1) CONTINOUS MONITORS ARE REQUIRED  FOR NOX, S02, AND CO. 2) TURBINE CURRENTLY PLANNED FOR IS THE GE FRAME 7. 3) OPERTION IS  LI
MITED TO 1500 HR/YR PER TURBINE.  ALSO UNDER SOURCE CODES 3.2 & 3.3
(*) INDICATES DATUM WAS TRUNCATED  FOR THIS TABLE.

PAGE G- 189
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS;  04/19/1934
                                                     ID NUMBER CA-0047
                                                                                                          SOURCE TYPE CODE
                                                                                                                               3.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/22/1984
SOURCE TYPE/SIZE---         NATURAL GAS  TURBINES                                            3200.00 HP


COMPANY NAME/SITE LOCATION  SW GAS STORAGE CO., PANHANDLE EAST. PIP*                              , KS
                            BROCHERS STATION                                                                          MEADE COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE--  12/11/80
PERMIT NO.                                                                                    ESTIMATED DATE OF START-UP--
DETERMINATION MADE BY       EPA REGION VII                 STEVE KOVAC                         (S16)-374-6525
                             (AGENCY)                  (AGENCY CONTACT PERSON)                    ( PHONE )



PROCESSES SUBJECT                    THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... * BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF


ENGINES, NAT. GAS FIRED,  5 1C R*   3200.00 HP EA
                                                          NOX     850.0000 PPM 15X 02 tD)                                   BACT


NOTES 	
BGRCHERS UNDERGROUND STORAGE FACILITY. (2-CYCLE, TURBO CHARGED ENGINES WITH STANDARD COMBUSTION CHAMBERS, DESIGNED TO OPERATE
AT RELATIVELY LOW SPEED)
<*) INDICATES DATUM WAS TRUNCATED FOR  THIS TABLE.

PAGE G- 190
                                                                                                     INITIAL REVIEW  POST STARTUP
                                                                                        REVIEW STATUS:  04/01/1933
ID NUMBER KS-0005
                                                     SOURCE TYPE CODE
                                                                         3.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/193^
SOURCE TYPE/SIZE—
                            NATURAL GAS TURBINES
                                                                                          18500.00 HP
COMPANY NAME/SITE LOCATION  TEXAS EASTERN  TRANSMISSION CO.
                                                                                          DELMONT,  PA
                                                                                                               WESTMORELAfJD COUNTY
DETERMINATION IS BACT FOR A MODIFIED SOURCE.
PERMIT HO. 82PA02
DETERMINATION MADE BY       EPA REGION III
                             (AGENCY)
                     VERNON BUTLER
                  (AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE—  07/07/83
                                       ESTIMATED DATE OF START-UP--   1982
                                       (215)-597-2711
                                           (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS                                    ... & BASIS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF
GAS TURBINE
                                  18500.00  HP
                                                          NOX
                                                                  150.0000 PPM
                                                                           NATURAL  GAS
                                                                                       BACT
NOTES
(*) INDICATES DATUM WAS TRUNCATED  FOR THIS TABLE.

PAGE G- 191
                                                                INITIAL REVIEW  POST STARTUP
                                                   REVIEW STATUS;   04/01/1933
                                                     ID NUMBER PA-0027
                                                                                                           SOLACE  TYPE  CCDE     3.1

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/23/1981*
SOURCE TYPE/SIZE	
                            NATURAL GAS TURBINES
                                                                                             88.00 MW
COMPANY NAME/SITE LOCATION  TOSCO CORP.
                                                                                         MARTINEZ, CA
                                                                                                              CONTRA COSTA COUNTY
DETERMINATION IS
PERMIT NO. 5193
DETERMINATION MADE BY
EPA REGION IX
 (AGENCY)
                                                          MATT HABER
                                                       (AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE--  13/13/83
                                       ESTIMATED DATE OF START-UP—   1984
                                       (415)-974-8209
                                           (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
          THROUGHPUT
           CAPACITY
POLLUTANT    EMISSION LIMITS                                   ... t BASIS
 EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
TURBINE, GAS, Z EA
        500.00  MMBTU/H
                                                          NOX      45.0000 PPM AT 15X 02
                                                                   75.0000 LB/H
                                                                           STEAM INJECTION
NOTES 	
TURBINES ARE GE FRAME 6 TURBINES. CEM REQUIRED  FOR NOX. PRIMARY FUEL IS REFINERY FUEL GAS, SECONDARY FUEL IS PIPELINE GAS.

2.) ALSO SOURCE TYPE 5.6
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 192
                                                                                                     INITIAL REVIEW  POST STARTUP
                                                                                        REVIEW STATUS;  04/19/1934
                          ID NUMBER CA-0046B
                                                                              SCUSCE TYPE  CODE     3.1

-------
                                            APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE—         NATURAL GAS TURBINES                                            8563.00  KM


COMPANY NAME/SITE LOCATION  UNIVERSITY CO-GENERATION  LTD-, 1983-1              BELLRIDGE OIL  FIELD,  CA
DETERMINATION IS      FOR A NEW SOURCE.                                                        DATE OF  PERMIT  ISSUANCE—  03/21/84
PERMIT NO. 4133001                                                                            ESTIMATED  DATE  OF  START-UP—
DETERMINATION MADE BY       KERN COUNTY  APCD               TOM PAXSON                          (805)-861-3682
                             (AGENCY)                    (AGENCY CONTACT  PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT         POLLUTANT    EMISSION  LIMITS                                    ...  4 BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS  MODIFICATION  ...  PCT EFF


TURBINE, GAS & BOILER, WASTE HE*   8563.00  KM
                                                          NOX     714.0000 LB/D
                                                                           H20 INJ., 0.9/1.0 W/F                            65.00


NOTES 	
EMISSION LIMITS MAY BE FIXED AT LOWER  LEVEL UPON EMISSIONS TESTING - UNIT WILL OPERATE 24 H/D, 7 D/WEEK,  52  WEEK/YR.
                                                                                                      INITIAL  REVIEW   POST STARTUP
(#) INDICATES DATUM WAS TRUNCATED  FOR  THIS TABLE.                                        REVIEW STATUS:

PAGE G- 193                                          ID NUMBER CA-0064                                     SOURCE  TYPE CODE    3.1

-------
                                             APPENDIX  — DETAILED  SOURCE  LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE—-         NATURAL GAS TURBINES                                              39.10  KW


COMPANY NAME/SITE LOCATION  VULCAN MATERIALS CO.                                            WICHITA,  KS
                                                                                                                   SEDGWICK COUNTY


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE  OF PERMIT ISSUANCE—  07/23/81
PERMIT NO.                                                                                     ESTIMATED  DATE OF  START-UP-
DETERMINATION MADE BY       EPA REGION VII                STEVE KOVAC                          (816J-374-6525
                             (AGENCY)                  (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT       POLLUTANT     EMISSION  LIMITS                                    ...  * BASIS
TO THIS PERMIT                         CAPACITY         EMITTED             CONTROL EQUIPMENT  OR PROCESS  MODIFICATION  ...  PCT EFF


TURBINE, SIMPLE-CYCLE, NAT. GAS      39.10 MW
                                                          NOX               SEE  NOTE                                          BACT
                                                                            STEAM  INJECTION


NOTES 	
THE UNIT IS SUBJECT TO NSPS, SUBPART GG.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 194
ID NUMBER KS-0009
                                                INITIAL PFVTFW  POST STARTUP
                                    _ V _ C r « w1 1 ~-\ o »J •   O'r/Cl/l?^^


                                                     SOURCE TYPE CODE    3.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/22/1984



SOURCE TYPE/SIZE-—         NATURAL  GAS TURBINES


COMPANY NAME/SITE LOCATION  WARREN RED. CO.                                                        , CA


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—  10/19/83
PERMIT NO. 2023008                                                                            ESTIMATED DATE OF START-UP—
DETERMINATION MADE BY       KERN COUNTY APCD               IVAN NEO                            (805)-861-3682
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... & BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT  EFF


I.C. ENGINE, NATURAL GAS, 3 EA    2133.00 HP
                                                          NOX      69.0600 LB/D
                                                                           CATALYTIC CONVERTOR                              86.00


NOTES 	
STATE FILE 8 A330-020
(*) INDICATES DATUM WAS TRUNCATED  FOR  THIS TABLE.

PAGE G- 195
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS:
                                                     ID NUMBER CA-0068
                                                                                                           SOLACE TYPE  CODE
                                                                                                                               3.1

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                         05/22/1984



SOURCE TYPE/SIZE-—         NATURAL GAS COMPRESSORS                                         4000.00 BRAKE HP
                           „______ __ ____--____._____.-____.- — — •___ — — — ,-_- — — — — __ — — — ._ — — — — — — _______„______ — -.—__ — — — ——— — — — — — — — _.._ — _ _ __.... _ .._« _w

COMPANY NAME/SITE LOCATION  ALGONQUIN GAS TRANSMISSION CO.                                CROKWELL, CT
                           ______•_ — ____.-«.____ ____—-__™ — — — __.__.. — _ ___ ___.._______ — ____.^__..__ —— .-_ — _ — — — .. — — — — — — — — — — — ..-. — — — — ~,^~ — — — —™ —— — — —

DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE Of PERMIT ISSUANCE—  03/05/82
PERMIT NO. 026-042CT01                                                                         ESTIMATED DATE OF START-UP—   1982
DETERMINATION MADE BY       EPA REGION I                   JOHN COURCIER                       (617)-223-4448
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... t BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF


EN3INE,TURBINE COMPRESSION           40.00 BHP
                                                           NOX       0.0135 •/. BY VOL                                         BACT
                                                                            MANUFACTURER'S GUARANTEE


NOTES 	
NSPS USED AS GUIDE, BUT MODIFICATION WAS NOT SUBJECT TO NSPS. BACT BASED ON MANUFACTURER'S GUARANTEE. LIMIT MEASURED AT  \S7. 02
 DRY BASIS.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.
                                                                                                      INITIAL VVIEW   POST  STARTUP
                                                                                         REVIEW STATUS:  04/01/1<=33
PAGE G- 196
                                                      ID NUMBER CT-0001
                                                                                                           SCU^CE TYPE CODE     3.2

-------
                                            APPENDIX -- DETAILED SOURCE  LISTING
                                                                                                                        05/82/198*



SOURCE TYPE/SIZE	         NATURAL GAS COMPRESSORS


COMPANY NAME/SITE LOCATION  ANR STORAGE CO.                                           EXCELSIOR  TUP,  MI 49000
                                                                                                                   KALKASKA COUNTY
                           _ .	_ «.	-. _ _				______,.__..___..___-.___	____.-	— — — — _	______	—	— —	_______

DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE  OF PERMIT ISSUANCE—  04/01/80
PERMIT NO. 67-80                                                                               ESTIMATED DATE OF START-UP—   1931
DETERMINATION MADE BY       MICHIGAN DNT?                  DAVID FERRIER                        (517)-32£-1333
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT         POLLUTANT     EMISSION LIMITS                                   ... S BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ... PCT EFF


COMPRESSOR, NAT. GAS, Z EA         3750.00 HP
                                                          NOX      12.0000  G/HP-H
                                                                            RETARDED IGNITION


NOTES 	
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 197
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW STATUS:  04/01/19S3    03/13/1934
ID NUMBER MI-0015
                                                     SOURCE TYPE CODE     3.2

-------
                                             APPENDIX  —  DETAILED  SOURCE  LISTING
                                                                                                                        05/23/1934



SOURCE TYPE/SIZE	         NATURAL GAS COMPRESSORS                                            20.00 MHP
                           __	_	__ ,	_	— —	__._.. — _	— _ —	— — —	—	—	__ —	—	—	— __ —

COMPANY NAME/SITE LOCATION  CO INTERSTATE GAS,  CHEYENNE                               NEAR ROCKPORT, CO
                                                                                                                       WELD COUNTY
                           	___	_ — —	_	— — —	— — — —	__.._______-..-__._	— — —	—	— _ — —	___-. —	___ —	_..__	_

DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE OF PERMIT ISSUANCE—  09/12/80
PERMIT NO.                                                                                     ESTIMATED  DATE OF START-UP--
DETERMINATION MADE BY       EPA REGION VIII               JOHN DALE                            (303J-837-3763
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHCUE)



PROCESSES SUBJECT                     THROUGHPUT       POLLUTANT    EMISSION LIMITS                                   ... & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL  EQUIPMENT OR  PROCESS  MODIFICATION  ... PCT EFF


2 ENGINES                          5130.00 HP
                                                          NOX       39.2400  LB/H                                              BACT
                                                                            DESIGN
2 REC ENGINES                      5130.00 HP
                                                          CO                                                                 BACT
                                                          NOX       68.0000  LB/H                                              BACT
                                                                            DESIGN
2 REC ENGINES                     12000.00 HP
                                                          CO                                                                 BACT
                                                          NOX      158.6000  LB/H                                              BACT
                                                                            DESIGN


NOTES 	









                                                                                                      INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEW STATUS:   04/01/1983

PAGE G- 198                                           ID  NUMBER CO-0001                                    SCU9CE TYPE CCQE    3.2

-------
                                            APPENDIX -- DETAILED SOURCE LISTING
                                                                                                                       05/22/1984



SOURCE TYPE/SIZE---         NATURAL  GAS COMPRESSORS                                           20.00 MHP


COMPANY NAME/SITE LOCATION  CO INTERSTATE GAS, DEERTRAIL                                          , CO
                                                                                                                    ELBERT COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE--  10/24/80
PERMIT NO.                                                                                    ESTIMATED DATE OF START-UP--
DETERMIHATION MADE BY       EPA REGION VIII                JOHN DALE                           (303J-837-3763
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... 4 BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF
ENGINE
2 ENGINES
GEN. ENGINE
HEATER
                                   6000.00 HP
                                  16000.00 HP
                                    425.00 HP
                                      6.00 MMBTU/H
                                                          CO
                                                          NOX
                                                          CO
                                                          NOX
                                                          CO
                                                          NOX
                                                          CO
                                                          NOX
                                                                   79.3000 LB/H
                                                                           DESIGN
                                                                  211.4000 LB/H
                                                                           DESIGN
                                                                   10.2000 LB/H
                                                                           DESIGN
                                                                    0.7600 LB/H
                                    BACT
                                    BACT
                                    BACT
                                    BACT
                                    BACT
                                    BACT
                                    BACT
                                    BACT
NOTES
(*> INDICATES DATUM WAS TRUNCATED  FOR  THIS TABLE.

PAGE G- 199
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS;  04/01/1933
                                                     ID NUMBER CO-0002
                                                                                                          SOURCE TYPE CCDE     3.2

-------
                                             APPENDIX  — DETAILED SOURCE  LISTING
                                                                                                                        05/22/1984




SOURCE TYPE/SIZE---         NATURAL GAS COMPRESSORS                                            66.00  MHP


COMPANY NAME/SITE LOCATION  CO INTERSTATE GAS,  FLANK                                  NEAR  LA  JUNTA,  CO
                                                                                                                       BACA  COUNTY


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE  OF PERMIT  ISSUANCE—  10/24/80
PERMIT NO.                                                                                     ESTIMATED  DATE  OF  START-UP--
DETERMIHATION MADE BY       EPA REGION VIII                JOHN DALE                            (303J-837-3763
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT       POLLUTANT     EMISSION  LIMITS                                    ... 4 BASIS
TO THIS PERMIT                         CAPACITY         EMITTED             CONTROL EQUIPMENT OR  PROCESS  MODIFICATION  ... PCT EFF
____„_»^__ — _____________„»„„_____ — — _„_„ — _____ — ____ — — — ~ — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —————— — — —


H3 GLYCO REBOIL                       8.00 MMBTU/H
                                                           NOX    8610.0000  SCFH                                              BACT
6 REC NG ENGS                     13320.00 HP
                                                           NOX      83.1000  LB/H                                              BACT
                                                                            DESIGN


NOTES 	
















                                                                                                      INITIAL  REVIEW  POST STARTUP
(») INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:   04/01/1933

PAGE G- 200                                           ID NUMSER CO-0003                                    SC'J-CE TYPE  CODE     3.2

-------
                                            APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                        05/23/1984



SOURCE TYPE/SIZE—         NATURAL GAS COMPRESSORS                                            44.00  MHP


COMPANY NAME/SITE LOCATION  CO INTERSTATE  GAS, KIT CARSON                                 NEAR  EADS,  CO
                                                                                                                   CHEYENNE COUNTY


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE  OF PERMIT ISSUANCE--  09/12/80
PERMIT NO.                                                                                     ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY       EPA REGION VIII                 JOHN  DALE                            (3031-837-3763
                             (AGENCY)                   (AGENCY  CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT         POLLUTANT     EMISSION LIMITS                                   ... t BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT  OR PROCESS MODIFICATION  ... PCT EFF
_	_	_ — —	_	— __	—	_	—	—	—	—	— ___._ — — _ —	-.— __ —	—	— -,	—	—	—	— —	—	„ — .___.-..._•,..__-.—

ENGINE, OPR                         370.00 HP
                                                           NOX        8.9000  LB/H                                              BACT
                                                                            DESIGN
                                                           CO                                                                 BACT
3 ENGINES                         16000.00 HP
                                                           CO                                                                 BACT
                                                           NOX     211.4000  LB/H                                              BACT
                                                                            DESIGN


NOTES 	













                                                                                                      INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEW STATUS:  04/01/1933

PAGE G- 201                                           ID NUMBER  CO-OC04                                     SC'JSCE TYPE CODE    3.2

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE---
                            NATURAL GAS COMPRESSORS
                                                                                              34.00 MHP
COMPANY NAME/SITE LOCATION  CO INTERSTATE GAS, TOTEM/LONG
                                                                                                  ,  CO
                                                                                                                     ELBERT COUNTY
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT NO.
DETERMINATION MADE BY       EPA REGION VIII
                             (AGENCY)
   JOHN DALE
(AGENCY CONTACT PERSON)
DATE OF PERMIT ISSUANCE--  09/12/80
ESTIMATED DATE OF START-UP--
(303>-837-3763
    (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
4 ENGINES



6 ENGINES

GENERATOR


2 HEATERS


THROUGHPUT
CAPACITY
1340.00 HP



2130.00 HP

370.00 HP


16.00 MMBTU/H


POLLUTANT
EMITTED

CO
NOX


CO

CO
NOX

CO
NOX
= = - = = = = = = = = rr = = rr = rr = = rrrr = rzr = = r = = r:rrr = = i:rrrrrrr = r =
EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION


53.1600 LB/H
DESIGN




8.9000 LB/H


2.5200 LB/H
... k BASIS
... PCT EFF

BACT
BACT


BACT

BACT
BACT

BACT
BACT
6 ENGINES
                                   8550.00 HP
                                                          NOX      216.6000  LB/H
                                                                            DESIGN
                                                                     BACT
NOTES
(*> INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 202
                                              INITIAL REVIEW   POST  STARTUP
                                 REVIEW  STATUS;   04/oi/i?e3
                                                     ID NUMBER CO-0005
                                                                                                          SC'J~CE TYPE CODE
                                                                                                                              3.2

-------
                                            APPENDIX -- DETAILED SOURCE LISTING
                                                                                                                       05/22/1984
SOURCE TYPE/SIZE---
                            NATURAL SAS COMPRESSORS
                                                                                             60.00 MHP
COMPANY NAME/SITE LOCATION  CO INTERSTATE GAS, WATKINS
                                                                                     NEAR WATKINS, CO
                                                                                                                     ADAMS COUNTY
DETEPMINATION IS BACT FOR A MODIFIED  SOURCE.
PERMIT NO.
DETERMINATION MADE BY       EPA  REGION  VIII
                             (AGENCY)
     JOHN DALE
  (AGENCY CONTACT PERSON)
DATE OF PERMIT ISSUANCE—  09/12/80
ESTIMATED DATE OF START-UP--
(333)-837-3763
    (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
ENGINE




4 ENGINES




5 ENGINES



THROUGHPUT POLLUTANT
CAPACITY EMITTED
1350.00 HP
CO
voc
NOX

10800.00 HP
CO
voc
NOX

30000.00 HP
CO
vcc
NOX
EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION



17.8400 LB/H
DESIGN



142.7200 LB/H
DESIGN



396.5000 LB/H
. . . fc BASIS
.. . PCT EFF

BACT
BACT
BACT


BACT
BACT
BACT


BACT
B4CT
EACT
                                                                           DESIGN
NOTES
(») INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 203
                                                                                                      INITIAL REVIEW   POST  STARTUP
                                                                                        REVIEW STATUS;   0^/01/1953
ID NUMBER CO-0006
                                                     SOURCE TYPE CCDE    3.2

-------
                                             APPENDIX  —  DETAILED  SOURCE LISTING
                                                                                                                        05/22/198"+



SOURCE TYPE/SIZE	         NATURAL GAS COMPRESSORS                                          1600.00 HP 2 EA


COMPANY NAME/SITE LOCATION  CONSOLIDATED GAS SUPPLY  CORP.                                          . WV
                            HASTINGS COMPRESSOR STATION                                                               WETZEL COUNTY


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE--  09/14/81
PERMIT NO. S1WV01                                                                              ESTIMATED DATE OF START-UP--   1932
DETERMINATION MADE BY       EPA REGION III                 BOB  BLASZCZAK                       (215)-597-3186
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION LIMITS                                   ...& BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ...  PCT EFF


I.C. ENGINE                        1600.00 HP
                                                           NOX        7.3300  G/SEC                                            BACT
                                                                            NCNE


NOTES 	
RELOCATION OF TWO 1600 HP. COOPER BESSEMER I.C. ENGINES.  THIS RELOCATION MASA MAJOR MODIFICATION  TO THE COMPRESSOR STATION REC
EIVINS THE ENGINES. THE ENGINES WERE 16 YEARS OLD  AND  NATURAL GAS-FIRED. OPERATION LIMITED  TO 5600 HRS./YR.
CONSOLIDATED G4S SUPPLY CO. REQUESTED A MOD. OF PSD  PERMIT  FROM USEPA REGION 3 ON 01/11/83.  HOD.  OF PERMIT  KOULD INVOLVE ALTER
NATE METHOD OF 0DER. OF COMPRESSOR ENGINES X AN INCREASE  IN EMISSION'S OF NOX.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 20<+
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW STATUS-'   04/01/1983
ID NUMBER WV-0001
                                                     SCU"CE TYPE CCDE
                                                                         3.2

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE-—         NATURAL GAS  COMPRESSORS


COMPANY NAME/SITE LOCATION  EL PASO NATURAL GAS CO., WASHINGTON RAN*                   WHITES CITY, NM


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        PATE OF  PERMIT ISSUANCE--  05/14/82
PERMIT NO. NM-428                                                                             ESTIMATED  DATE OF  START-UP—    1932
DETERMINATION MADE BY       AIR QUALITY  BUREAU - NMEID     SHANKAR ANANTHAKRISHNA              (505>-934-0020
                             (AGENCY)                    (AGENCY CONTACT  PERSON)                     ( FHQ!,'E )



PROCESSES SUBJECT                     THROUGHPUT         POLLUTANT    EMISSION  LIMITS                                    ...» BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS  MODIFICATION  ...  FCT EFF


ENGINE, I.C. COMPRESSOR            4500.00 HP
                                                          NOX       2.4500 G/HP-H
                                                                           COOPER ENERGY  SERVICES
ENGINE, I.C. COMPRESSOR            4500.00 HP
                                                          NOX       2.4500 G/HP-H
                                                                           COOPER ENERGY  SERVICES


NOTES 	
STACK TEST PERFORMED ON THESE TWO ENGINES BUT NO REPORT  RECIEVED YET.














                                                                                                      INITIAL WVIEM  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR  THIS TABLE.                                        REVIEW STATUS:  04/01/1933

PAGE G- 205                                          ID NUMBER NM-OOC6                                     SOURCE TYPE CC3E     3.2

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                         05/22/1984



SOUPCE TYPE/SIZE---         NATURAL GAS COMPRESSORS
                           _____-__..__ — _ — ____ — — _ — _ — — __ _-___—.—.«. — — ____.-•_..___ — ——————— — — __-.____ — -,____ — — — —. — _ — — .._ _ — ____ — —.._-__ _,- — ___________ —

COMPANY NAME/SITE LOCATION  ENSERCH EXPLORATION CO.                                               , TX
                                                                                                                    EASTLAND  COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE--   12/28/82
PERMIT NO. X-4051                                                                              ESTIMATED DATE OF START-UP--    1933
DETERMINATION MADE BY       TEXAS ACB                      RANDY HAMILTON                      (512J-451-5711
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... 4 BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF


WHITE SUPERIOR 8G825                780.00 HP
                                                           NOX       7.7000 T/YR
                                                                            CATALYTIC CONVERTER                               90.00
                                                           CO        5.5000 T/YR
                                                           VOC       0.7000 T/YR


NOTES 	
EMISSION LIMITS ARE 1.0 G/HP-H NOX, 0.75 6/HP-H" CO, 0.1 G/HP-H VOC.














                                                                                                      INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:  C5/04/19S4

PAGE G- 206                                           ID NUMBER TX-0133                                    SOURCE TYPE CODE     3.2

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/23/1984
SOURCE TYPE/SIZE — -
                            NATURAL GAS COMPRESSORS
COMPANY NAME/SITE LOCATION  GETTY OIL CO.
                                                                                       SKELLYTOWN, TX
                                                                                                                     CARSON COUNTY
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT NO. X3378
DETERMINATION MADE BY       TEXAS ACB
                             (AGENCY)
   RANDY HAMILTON
(AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE—  10/18/82
                                       ESTIMATED DATE OF START-UP—   1983
                                                                                                   ( FKCNE )
PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                    ...  t BASIS
TO THIS PERMIT                         CAPACITY           EMITTED            CONTROL EQUIPMENT  OR  PROCESS  MODIFICATION  ...  PCT EFF


SUPERIOR 126TA 'CLEAN BURN1  ENG*   2000.00  HP
                                                          NOX       77.2000 T/YR
                                                                           COMBUSTION  CHAMBER MOD.
                                                          CO       115.8000 T/YR
                                                          VOC       8.^.000 T/YR


NOTES 	
2.0 G/HP-H NOX, 3.0 G/HP-H CO, 0.2 G/HP-H VOC














                                                                                                      INITIAL REVIEW  POST  STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS  TABLE.                                         REVIEW STATUS:   04/01/1933

PAGE G- 207                                          ID  NUMBER TX-0101                                     SCURCE  TYPE CODE    3.2

-------
                                             APPENDIX  — DETAILED  SOURCE  LISTING
                                                                                                                        05/23/1984
SOURCE TYPE/SIZE	         NATURAL GAS COMPRESSORS                                           200.00  MHSCFD
                           __	_	—	— —	__ — .._,_	— _ ——	


COMPANY NAME/SITE LOCATION  LIQUID ENERGY CORP.                                                    .  TX
                                                                                                                       WISE  COUNTY
DETERMINATION IS BACT FOR A NEW SOURCE.                                                         DATE  OF  PERMIT  ISSUANCE—   11/10/63
PERMIT NO. 9153                                                                                ESTIMATED  DATE  OF  START-UP--    1933
DETERMINATION MADE BY       TEXAS ACB                      KAREN HORNE                          (512J-451-57I1
                             (AGENCY)                   (AGENCY  CONTACT PERSON)                    ( FHOS'E )
PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ...  4 BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT OR  PROCESS  MODIFICATION  ...  PCT  EFF


TURBINE ENGINE COMPRESSOR, 2 EA    3200.00 HP
                                                           NOX       1.7500  G/HP-H
MEP-8 RECIPROCATING ENGINE COMP*   2000.00 HP
                                                           NOX       4.0000  G/HP-H
                                                                            TURBOCHARGERS


NOTES 	
THE EFFECTIVENESS OF TURBOCHARGERS HAS NOT BEEN PROVEN BY PERFORMANCE TESTING YET.
                                                                                                      INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEW STATUS:   05/04/19S4
PAGE G- 203                                           ID NUMBER  TX-0128                                    SOURCE TYPE CCDE    3.2

-------
                                            APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                        05/23/1984
SOURCE TYPE/SIZE---
                            NATURAL GAS COMPRESSORS
COMPANY NAME/SITE LOCATION  LLANO,  INC.
                                                     NEAR  HCBBS,  KM
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT NO. NM-477
DETERMINATION MADE BY       AIR QUALITY  BUREAU  - NMEID     SHANKAR ANANTHAKRISHNA
                             rAGENCY)                    fAGENCY CONTACT  PERSON)
                                                            DATE OF PERMIT ISSUANCE—  06/22/82
                                                            ESTIMATED DATE OF START-UP--   1982
                                                            (505)-984-OOcO
                                                                CPHCJiE)
PROCESSES SUBJECT
TO THIS PERMIT
   THROUGHPUT
    CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
.. .  &  BASIS
...  PCT EFF
ENGINE, I.C. COMPRESSOR
ENGINE, I.C. COMPRESSOR
ENGINE, I.C. COMPRESSOR
ENGINE, I.C. COMPRESSOR
ENGINE, I.C. COMPRESSOR
                                   1100.00  HP
                                   1100.00  HP
                                   1100.00  HP
1100.00 HP
                                   1100.00  HP
   NOX       2.2000 G/HP-H
                    NEW DESIGN

   NOX       2.2000 G/HP-H
                    NEW DESIGN

   NOX       8.2000 G/HP-H
                    NEW DESIGN

   NOX       2.2000 G/HP-H
                    NEW DESIGN

   NOX       2.2000 G/HP-H
                    NEW DESIGN
NOTES 	
STACK TESTS, EPA REF. METHOD 7,  WERE PERFORMED  ON  TWO OF THE ABOVE  MENTIONED  FIVE  ENGINES  &  THE  ACTUAL EMISSIONS WERE 0.38 G/H
P-H t 1.34 G/HP-H.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 209
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW STATUS;   04/01/1933
                                                      ID  MU.k!3ER  KM-0009
                                                                                                           SOl'~CE TYPE CODE    3.;

-------
                                             APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE-—         NATURAL GAS COMPRESSORS                                         4000.00 HP 2  EA


COMPANY NAME/SITE LOCATION  MICHIGAN WISCONSIN  PIPE  LINE CO.                     CHARLTON TOWNSHIP, MI 49000
                                                                                                                    OTSEGO COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                       DATE OF PERMIT  ISSUANCE—  11/01/80
PERMIT NO. 660-80                                                                             ESTIMATED  DATE  OF START-UP—    1983
DETERMINATION MADE BY       MICHIGAN DNR                  GREGORY  EDWARDS                     (517)-322-1333
                             (AGENCY)                  (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT       POLLUTANT     EMISSION  LIMITS                                    ... t BASIS
TO THIS PERMIT                         CAPACITY         EMITTED            CONTROL EQUIPMENT OR PROCESS  MODIFICATION   ... PCT ErF


COMPRESSOR, NAT. GAS, 2 EA         4000.00 HP
                                                          NOX       12.3000 G/HP-H
                                                                           COMBUSTION MODIFICATIONS


NOTES 	
2 NATURAL GAS COMPRESSORS.
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 210
ID NUMBER MI-0016
                                                INITIAL REVIEW  POST STARTUP
                                   REVIEW STATUS:   04/01/1933    03/13/19S4

                                                     SOLACE TYPE CODE    3.2

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1934
SOURCE TYPE/SIZE — -
                            NATURAL  GAS COMPRESSORS
                                                                                           1669.00 HP
COMPANY NAME/SITE LOCATION  PANHANDLE  EAST. PIPELINE CO.
                            COGNAC STATION
                                                                                                   KS
                                                                                   GRANT COUNTY
DETERMINATION IS BACT FOR A MODIFIED SOURCE.
PERMIT NO.
DETERMINATION MADE BY       EPA REGION VII
                             (AGENCY)
                        STEVE KOVAC
                     (AGENCY CONTACT  PERSON)
                                       DATE OF PERMIT ISSUANCE—  07/28/80
                                       ESTIMATED DATE OF START-UP—
                                       (816)-374-6525
                                           (FHQKE)
PROCESSES SUBJECT
TO THIS PERMIT
   THROUGHPUT
    CAPACITY
POLLUTANT    EMISSION LIMITS                                   ...» BASIS
 EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
I.C. RECIP. ENGINE, UNITS3
1669.00 HP
                                                          NOX
                                700.0000  PPM 15X 02 (D)
                                         PRE-IGNITION CHAMBER
                                                                                                                             BACT
NOTES 	
IF CONSTRUCTION COMMENCES PRIOR TO JANUARY/1932,  THE  UNIT WILL NOT BE SUBJECT  TO  PROPOSED  SUBPART  FF  OF  THE NSPS REGS.  THE PER
MIT, HOWEVER, INCORPORATES SEVERAL PROVISION'S OF  PROPOSED SUBPART FF AS  PERMIT CONDITIONS.
(*> INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 211
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW STATUS:   04/01/1933
                   ID NUMBER KS-0002
                                                                        SOURCE TYPE CODE    3.2

-------
                                             APPENDIX  — DETAILED  SOURCE  LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE—-         NATURAL 6AS COMPRESSORS                                            18.00  MHP


COMPANY NAME/SITE LOCATION  PANHANDLE EAST.  PIPELINE-FRED.                                         »  CO
                                                                                                                       WELD COUNTY
                           	

DETERMINATION IS BACT                                                                          DATE  OF PERMIT ISSUANCE—  11/25/81
PERMIT NO.                                                                                     ESTIMATED  DATE OF START-UP-
DETERMINATION MADE BY       EPA REGION VIII                 JOHN DALE                            (303>-337-3763
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION LIMITS                                   ... t BASIS
TO THIS PERMIT                         CAPACITY         EMITTED            CONTROL EQUIPMENT OR PROCESS  MODIFICATION  ... PCT EFF
	_ —	———__—	— — —	...	.._ — _ — — — _.	— —	— — —	— — —	— —	— —	— — — — — — — — —	. — — — — — — _ — —	— — —	—	—	—	— — — — — — —	— —

REC COMP ENG                       4500.00 HP
                                                           CO                                                                 BACT
                                                           VOC    -                                                            BACT
                                                           NOX        5.5000  6/HP-H                                           BACT
                                                                            ENS MODS                                         55.00


NOTES 	















                                                                                                      INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM HAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:   04/01/1=33

PAGE G- 212                                           ID NUflSER CO-0010                                     SOLTCE T^PE CODE    3.2

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/22/1984



SOURCE TYPE/SIZE—-         NATURAL  GAS COMPRESSORS                                        13746.00 HP


COMPANY NAME/SITE LOCATION  PANHANDLE  EAST., FT. LUPTON                                           , CO
                                                                                                                      WELD COUNTY


DETERMINATION IS BACT                                                                         DATE OF PERMIT ISSUANCE—  05/29/80
PERMIT NO.                                                                                    ESTIMATED DATE OF START-UP—
DETERMINATION MADE BY       EPA REGION VIII                JOHN DALE                           (303)-837-3763
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... * BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... FCT EFF


REC COMP ENG, 3                   2246.00 BRAKE HP EA
                                                          NOX      55.0000 LB/H EA                                          BACT
                                                                           ENS DESIGN & MODIFICATINS
NOTES
                                                                                                     INITIAL REVIEW   POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED  FOR THIS TABLE.                                        REVIEW STATUS:  04/01/1033

PAGE G- 213                                          ID NUJI3ER CO-OC11                                    SCUSCE TYPE CCDE     3.2

-------
                                             APPENDIX  -- DETAILED SOURCE  LISTING
                                                                                                                        05/22/193*
SOURCE TYPE/SIZE---         NATUPAL GAS COMPRESSORS


COMPANY NAME/SITE LOCATION  PHILLIPS PETROLEUM CO.                                                 , TX
                                                                                                                    WINXLER  COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                       DATE OF  PERMIT  ISSUANCE—   12/15/82
PERMIT NO. X-3903                                                                             ESTIMATED  DATE  OF  STA9T-UP--    1932
DETERMINATION MADE BY       TEXAS ACB                     RANDY HAMILTON                      (512)-451-5711
                             (AGENCY)                   (AGENCY CONTACT  PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION  LIMITS                                    ... & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT  OR  PROCESS  MODIFICATION   ... PCT EFF


WAUKESHA 6LRZB-9                    220.00 HP
                                                          NOX       23.4000 T/YR
                                                                           EQUAL NOX-CO  CARBURETOR SETTING
                                                          CO        23.4000 T/YR
                                                          VOC        4.5000 T/YR
SUPERIOR 8G825                      585.00 HP
                                                          NOX       62.1000 T/YR
                                                          CO        62.1000 T/YR
                                                          VOC        5.4000 T/YR


NOTES		—
RICH-BU INDICATES DATUM HAS TRUNCATED FCR THIS TABLE.                                         REVIEW STATUS:   05/04/19^%

PAGE G- 214-                                          ID  NUMBER TX-0125                                    SOL-.CE TiPE  CODE     3.2

-------
                                             APPENDIX  — DETAILED SOURCE  LISTING
                                                                                                                        05/22/198*



SOURCE TYPE/SIZE---         NATURAL GAS COMPRESSORS
                           _....__-...-.____«.,,——,	____	_ — — _, — — — — — _._— — — — — — — — — — — — ..—	_ — — — — — — _ — — — — — -.	_ — — — — ___ — _ — — — — — — — — -. — — — — — — —— — — — — — — — —

COMPANY NAME/SITE LOCATION  SANTA FE ENERGY                                                       > CA


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE OF PERMIT ISSUANCE--  12/02/82
PERMIT NO. 0951                                                                                ESTIMATED DATE OF START-UP--
DETERMINATION MADE BY       VENTURA COUNTY                KEITH DUVAL                          (805 )-65<*-266*
                             (AGENCY)                  (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT       POLLUTANT     EMISSION LIMITS                                    ... 4 BASIS
TO THIS PERMIT                         CAPACITY         EMITTED             CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF


COMPRESSOR, NATURAL GAS             180.00 HP
                                                          NOX     150.0000 PPM


NOTES 	
STATE FILE * A330-030
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 215
                                                                                                       INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW  STATUS:
ID NUMBER CA-0073
                                                      SOURCE  TYPE  CODE    3.2

-------
                                             APPENDIX  -- DETAILED SOURCE  LISTING
                                                                                                                        05/22/193'*
SOURCE TYPE/SIZE	
                            NATURAL GAS COMPRESSORS
                                                                                            2000.00 HP  EA
COMPANY NAME/SITE LOCATION  SOUTHERN NAT.  GAS
                            P.O. BOX 2563
                                                                                       BIRMINGHAM,  AL  35202
                                                                            JEFFERSON COUNTY
DETERMINATION IS BACT FOR A MODIFIED SOURCE.
PERMIT NO. (REGION FILE NO. ) PSD-AL-055
DETERMINATION MADE BY       ALABAMA APCD
                             (AGENCY)
                     SUE  ROBERTSON
                  (AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE—  01/29/80
                                       ESTIMATED DATE OF START-UP--
                                       (205J-S34-6570
                                           (FHCNE)
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
& BASIS
FCT EFF
VERT COMPRESSOR ENGINES, 3 EA
                                   6000.00  HP
                                                          NOX
                                                                    16.5000 GM/HP-H
                                                                           COMBUSTION  CONTROL
                                                                                                                             BACT
NOTES 	
THREE UNITS.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS T4BLE.

PAGE G- 216
                                                                                                      INITIAL  REVIEW  POST  STARTUP
                                                                                         REVIEW  STATUS:   C-f/01/lcS3
                ID NUMBER  AL-0011
                                                                     SCL'ECE TYPE CC3E    3.2

-------
                                            APPENDIX -- DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE---         NATURAL GAS COMPRESSORS                                         4000.00 HP


COMPANY NAME/SITE LOCATION  SOUTHERN NAT.  GAS                                              GALLION, AL  36742
                            P.O.  BOX 68                                                                                HALE  COUNTY


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF  PERMIT  ISSUANCE—  06/04/81
PERMIT NO. PSD-AL-074                                                                         ESTIMATED  DATE  OF  START-UP—    1962
DETERMINATION" MADE BY       ALABAMA APCD                  SUE ROBERTSON                       (2C5)-834-6570
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... i BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS  MODIFICATION  ... PCT EFF
— —	—- — — — — -. —	— — — — — — — — — — — — — — — — — — — —— _ — — — -_——-______________fc___»___________ —__«_____________„__„______ ___________..___________.».___.. _

VERTICAL COMPRESSOR ENGINE         4000.00 BRAKE HP
                                                          NOX      15.0000 G/HP-H
                                                                           EQUIPMENT OPERATION


NOTES 	
MANUFACTURER EMISSION TEST
<*) INDICATES DATUM WAS TRUNCATED  FOR  THIS TABLE.

PAGE G- 217
                                                     ID NUMBER AL-0012
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS--  04/01/1933
                  SOURCE TYPE CODE    3.2

-------
                                             APPENDIX -- DETAILED SOURCE  LISTING
                                                                                                                        05/32/1984



SOURCE TYPE/SIZE	         NATURAL GAS COMPRESSORS                                         5000.00 BRAKE HP


COMPANY NAME/SITE LOCATION  SOUTHERN NAT.  GAS                                              ELMCRE, AL 36025
                            P.O. BOX 67                                                                             ELMORE COUNTY


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE--  06/04/81
PERMIT NO. (REGION FILE NO.) PSD-AL-075                                                       ESTIMATED DATE OF START-UP--    1982
DETERMINATION MADE BY       ALABAMA APCD                  SUE ROBERTSON                       (2051-834-6570
                             (AGENCY)                  (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                    ... * BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF


VERTICAL COMPRESSOR ENGINE         5000.00 BRAKE HP
                                                          NOX      15.0000 6/HP-H                                           BACT
                                                                           EQUIPMENT OPERATION


NOTES 	
MANUFACTURER EMISSION TEST
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 218
                                                                                                     INITIAL REVIEW  POST STARTUP
                                                                                        REVIEW STATUS:  04/01/15S3
ID NUMBER AL-0013
                                                     SC'JRCE TYPE CCDE
                                                                         3.2

-------
                                             APPENDIX —  DETAILED SOURCE LISTING
                                                                                                                         05/22/1984



SOURCE TYPE/SIZE	         NATURAL GAS COMPRESSORS                                        15500.00 HP
                           _ — _,»_ „___ ___	__•».	„	___.._	_**__-.____....	— —_	>._....._...._...._...^ — ~-.-	—	— — _ — _____ — — _—— — — -. —	—	-. — _-. — — —

COMPANY KAME/SITE LOCATION  TENNESSEE GAS PIPELINE CO.                                  MARIONVILLE, PA
                                                                                                                     FOREST  COUNTY


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE OF PERMIT ISSUANCE--  03/01/83
PERMIT NO. 27-399-001                                                                          ESTIMATED DATE OF  START-UP—    1983
DETERMINATION MADE BY       PENNSYLVANIA BAQ, DER          WILLIAM CHARLTON                    (814)-724-S530
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)

= = = r = = = = = r = = = = r = = = = = = r = = = = r = r = = = r = = = :r = = = r = z = = = r = = = = = = = = = = = = = = = = = = r = = = = = = = = = = = = = r = 5 = = = = = = = = = = = = === = = = = r = r = = z = z = = === = = = r= = = = = = r=rr =

PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF
— ^ — — — — _ — — —. — _. — — —^_ —— — »__ — -,„__ — — ____ —___ — -,____™. —___%.»_ — — __——.—,__ — — — — — —.— — — — — — — — — — •—. — — — — — — — — — — — — —. — — — — — — — — — — — — — — — — — — — — — — — — — — — —• — — — — — — — — — —

GAS COMPRESSOR                    15500.00 HP
                                                           NOX                                                                PSD
                                                                            LEAN BURN PROC./AIR-FUEL RATIO ADJUST.


NOTES 	
EXISTING CAPACITY IS 11500 HP. PROPOSED ADDITIONS ARE 4000 HP. TOTAL CAPACITY WILL BE 15500 HP.
                                                                                                       INITIAL REVIEU  POST STARTUP
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEW STATUS:   04/01/1°S3
PAGE G- 219                                           ID NUfSER FA-OOCS                                     SOURCE TYPE CODE    3.2

-------
                                             APPENDIX  — DETAILED  SOURCE  LISTING
                                                                                                                        05/23/1984
SOURCE TYPE/SIZE---         NATURAL GAS COMPRESSORS                                          2250.00 HP
                           	„		—	— — — —	— —.	— — — —	__ — -. — — —	—	—	— —


COMPANY NAME/SITE LOCATION  TRANSCONTINENTAL GAS  PIPELINE  CORP.                              GILLIS, LA
                                                                                                                 BEAUPEGARD PARISH


DETERMINATION IS BACT                                                                          DATE OF PERMIT ISSUANCE—  10/14/83
PERMIT NO. PSO-LA-506                                                                          ESTIMATED DATE OF START-UP—   1933
DETERMINATION MADE BY       LAQD/EPA REGION VI            HARENDRA  RAOL                       (504)-342-8S40
                             (AGENCY)                   (AGENCY  CONTACT  PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT         POLLUTANT     EMISSION  LIMITS                                    ... t BASIS
TO THIS PERMIT                         CAPACITY         EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
	

ENGINE, RECIPROCATING COMPRESSOR   2250.00 HP
                                                          NOX       29.7000  LB/H
                                                                            CLEAN  BURN ENGINE, MOO. COMB. W/CCNTRLS          55.00



NOTES 	



















                                                                                                      INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:
      _    		___ — _ — — —	—	____» — ___ -%— __________ — — _ — — — — —	_,___.___ _ __ — -. ~. ~ — — — — — — — — — — — zz~n ~~~n ~ — — ~~ — ~ ~ — ~ — — ~~~ ~
PAGE G- 220                                           ID NUMBER  LA-0043                                     SCL.TCE TYFE CCQE    3.2

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                         05/22/1964



SOURCE TYPE/SIZE—-         NATURAL GAS COMPRESSORS


COMPANY NAME/SITE LOCATION  TRANSHESTERN PIPELINE CO.,  BITTER LAKE *                  NEAR ROSWELL, NM
                           — — — — — -• — — — — — — — — — — — — — — — — — — — — — — — — — — ——... — — — — — — ._ — — — — — — ..— — — — — — -. — — — _ — .— —, — — — ,_•. — —. — — — • — — .. — — — ,. — •_ — _ — .„ — — — — — — ._ — — .._ — — _ —

DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE— 09/23/82
PERMIT NO. NM-274-M-2                                                                          ESTIMATED DATE OF START-UP—
DETERMINATION MADE BY       AIR QUALITY BUREAU - NMEID      SHANKAR ANANTHAKRISHNA              (505J-934-0020
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... &  BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF


ENGINE, I.C. COMPRESSOR            1596.00 HP
                                                           NOX       4.0000 G/HP-H
                                                                            LOW NOX ENGINE


NOTES 	
STACK TEST PERFORMED, EPA REF. METHOD 20, RESULTS - 2.96 G/HP-H
(*) INDICATES DATUM WAS TRUNCATED FC3 THIS TABLE.

PAGE G- 221
                                                      ID  NUMBER  NM-0013A
        Tf-'TTTiL REVIEW  POST STARTUP
x STATUS;  04/01/1933

             SOURCE TYPE CCQE     3.3

-------
                                             APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE	         NATURAL GAS COMPRESSORS
                             _        _ —  _——___————————— _______.___ — — _,——————————————————————————— —————— —————— —————————————————————

COMPANY NAME/SITE LOCATION  TRANSWESTERN PIPELINE  CO., BITTER  LAKE *                   NEAR  ROSWELL, NM
                           -	-—_	--	—	_---	----	_—-_--_-_--.—-----—--------- —

DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE OF PERMIT ISSUANCE—  05/03/82
PERMIT NO. NM-274-M-1                                                                          ESTIMATED  DATE OF  START-UP—   1982
DETERMINATION MADE BY       AIR QUALITY BUREAU - NMEID     SHANKAR ANANTHAKRISHNA               (5051-984-0020
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHCKE)

rr = r = r:r:=r: = = = = = = = = = = r:; = r = = rr = ::rrr: = = = = = = r = = = = : = r = = = r = = = = = = = = = = = = = = rr = = = r = = r = = = = r = r = = = = = = = r = r = = = r = = r = = = = = = = = = = = = = = = - = = = = = = = = = --

PROCESSES SUBJECT                     THROUGHPUT         POLLUTANT    EMISSION  LIMITS                                    ...& BASIS
TO THIS PERMIT                         CAPACITY         EMITTED            CONTROL EQUIPMENT OR PROCESS  MODIFICATION   ... PCT EFF
	

ENGINE, I.C. COMPRESSOR            1050.00 HP
                                                          NOX      5.00CO G/HP-H
                                                                           LOW NOX ENGINE


NOTES 	
STACK TEST PERFORMED, EPA REF. METHOD 20, RESULTS  - 2.42 G/HP-H
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 222                                           ID  NUMBER  NM-0013
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW STATUS:   0^/01/1583
SOURCE TYPE CODE
                    3.2

-------
                                             APPENDIX  —  DETAILED  SOURCE LISTING
                                                                                                                         05/22/1984




SOURCE TYPE/SIZE—         NATURAL GAS COMPRESSORS
                           _	*.	_	—	—	___.-._ — — -,_._—— — ^. — — — —— — —— — — --«* — •- — — — — ™ —•• — — — — — — — — — — — — — — — — —  ___«._..__...._ — .. — — -. — ..—— — — — — —

COMPANY NAME/SITE LOCATION  TRANSWESTERN PIPELINE CO., ISLER NO. 1 *                  NEAR ROSWELL, HM
                                _ —— _	___	—	_	 __„______„_«. «.____ — _ ____-.-. __-. — •*_ — — — — — — — — — — — — — — — — — — — — — — — — — — — » — — — — — — — — — —

DETERMINATION IS BACT FOR A NEW SOURCE.                                                        CATE OF PERMIT ISSUANCE--  05/08/82
PERMIT NO. NM-464                                                                              ESTIMATED DATE Of START-UP—   1982
DETERMINATION M4DE BY       AIR QUALITY BUREAU - NMEID     SHANKAR ANANTHAKRISHNA              (5051-984-0020
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



FROCESSCS SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    .. . « BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF
	

ENGINE, I.C. COMPRESSOR            1588.00 HP
                                                           NOX       4.0000 G/HP-H
                                                                            LOW NOX ENGINE


NOTES 	
STACK TEST PERFORMED, EPA REF. METHOD 20, — RESULTS - 2.06 G/HP-H
 (*)  INDICATES DATUM WAS  TRUNCATED  FOR  THIS TABLE.

 PAGE G-  223
                                                                                                       INITIAL FrtVIEW  POST STARTUP
                                                                                          REVIEW STATUS:  04/01/1933
ID NUMBER NM-0014
                                                      SC'JRCE TYPE CODE    3.2

-------
                                              APPEKDIX  --  DETAILED  SOURCE LISTING
                                                                                                                          05/22/1984



SOURCE TYPE/SIZE---         NATURAL  GAS  COMPRESSORS
                            — — — — —.- — — — — — — — — — — _ — —. — — _.• — -.__._.- — __.__..____.»___ ___ — _____..___.,__ _ ___ ____ _____•.__ __ _ __ — ____.» ___ „_« — — ___ — ..__.„.„_

COMPANY NAME/SITE LOCATION  TRANSWESTERN PIPELINE CO., KEMNITZ  STAT*                 NEAR MALJAMAR, MM
                            — — — — — ~ — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — .— — — — — ..-- — — —..P. — — —- — -- — —... — .-.. — .. — ___ — .,__.•,_._«_.___—...__.1_ —— _

DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE OF PERMIT ISSUANCE—  05/03/82
PERMIT NO. NM-399-M-1                                                                           ESTIMATED DATE OF  START-UP—   1932
DETERMINATION MADE BY       AIR QUALITY  BUREAU - NMEID     SHANKAR ANANTHAKRISHNA              (505 J-984-0020
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    ( FKON'E )



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION LIMITS                                   . . .  & BASIS
TO THIS PERMIT                         CAPACITY           EMITTED             CONTROL EQUIPMENT OR PROCESS MODIFICATION  ...  PCT EFF


ENGINE, I.C. COMPRESSOR            1072.00 HP
                                                           NOX        5.0000 6/HP-H
                                                                             LOW NOX ENGINE


NOTES 	
STACK TEST PERFORMED, EPA REF. METHOD 20, —  RESULTS - 4.15 G/HP-H
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 224
                                                      ID NUMBER NH-0012
             INITIAL REVIEW   POST  STARTUP
REVIEW STATUS:  O-VOl/1933

                  SOURCE TYPE  CODE    3.2

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE---         NATURAL GAS COMPRESSORS


COMPANY NAME/SITE LOCATION  TRANSU'ESTERN PIPELINE CO., RED BLUFF ST*                  NEAR ROSWELL,  NM


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE  OF PERMIT ISSUANCE—  05/03/82
PERMIT NO. NM-411-M-1                                                                          ESTIMATED  DATE OF START-UP—   1982
DETERMINATION MADE BY       AIR QUALITY BUREAU - NMEID     SHANKAR ANANTHAKRISHNA               < 505 )-9S<4-0020
                             (AGENCY)                  (AGENCY CONTACT  PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                    ...  i BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT  OR PROCESS  MODIFICATION  ...  PCT EFF


ENGINE, I.C. COMPRESSOR            1596.00  HP
                                                          NOX       A.0000  G/HP-H
                                                                            LOU NOX ENGINE


NOTES 	
STACK TEST PERFORMED, EPA REF.  METHOD 20, RESULTS — 3.58 G/HP-H
<*) INDICATES DATUM WAS TRUNCATED  FOR  THIS  TABLE.

PAGE G- 225
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS:
                                                     ID NUMBER NM-0010
                                                                                                           SOURCE TYPE CCDE    3.2

-------
                                             APPENDIX —  DETAILED  SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE-—         NATURAL GAS COMPRESSORS


COMPANY NAME/SITE LOCATION  TRANSWESTERN PIPELINE CO.,  RED  BLUFF ST*                  NEAR ROSWELL,  NM


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE  OF PERMIT ISSUANCE--  05/03/82
PERMIT NO. NM-412-M-1                                                                          ESTIMATED DATE OF START-UP—   19S2
DETERMINATION MADE BY       AIR QUALITY BUREAU - NMEID      SHANKAR ANANTHAKRISHNA              (5051-984-0020
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION LIMITS                                   ...& BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
_________...._____-._ — ___.— — ___— — — _—_—^—___ — — — __—— — — — —. — — —. — —_ — — —— __———__ _. _ ______ — «___ ___ r- — — ___ — —-.—-. — —— — -.——.— ———— — — — — _ v — — — _ _———___ — — — __ —

ENGINE, I.C. COMPRESSOR            1073.00 HP
                                                           NOX       5.0000 G/HP-H
                                                                            LOW NOX ENGINE


NOTES 	
STACK TEST PERFORMED, EPA REF. METHOD 20, RESULTS —  2.4 G/HP-H
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 2£6
ID NUMBER NM-0010A
                                                INITIAL REVIEW  POST STARTUP
                                   REVIEW STATUS;  04/01/1033
                                                     SCURCE TYPE CCDE    3.2

-------
                                             APPENDIX —  DETAILED SOURCE LISTING
                                                                                                                         05/22/1984



SOURCE TYPE/SIZE-—         NATURAL GAS COMPRESSORS


COMPANY NAME/SITE LOCATION  TRANSWESTERN PIPELINE CO., RED BLUFF ST*                  NEAR ROSWELL, NM


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE OF PERMIT ISSUANCE—  05/03/82
PERMIT NO. NM-413-M-1                                                                          ESTIMATED DATE OF START-UP—    1932
DETERMINATION MADE BY       AIR QUALITY BUREAU - NMEID     SHANKAR ANANTHAKRISHNA              (505)-934-0020
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHCNE )



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ...  4 BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ...  PCT EFF
— — — — — — — — — — — ___ — — —._____ »___ _-,___ _ __ _• — — ™. — ______» ______ ..____«.•. — — __ — .... — ,.__ — «,-.___ — — -_ ______-__.—.___ — __ — ______„.-_____ _ ^ _ _ — »__._ ______..-.____..

ENGINE, I.C. COMPRESSOR            1588.00 HP
                                                           NOX       4.0000 G/HP-H
                                                                            LOW NOX ENGINE


NOTES 	
STACK TEST PERFORMED, EPA REF. METHOD 20, RESULTS — 2.51 G/HP-H
(») INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 227
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS:  04/01/1933
                                                      ID NUMBER NM-0010B
                                                                                                            SOURCE  TYPE CCDE    3.2

-------
                                             APPENDIX  --  DETAILED  SOURCE  LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE — -         NATURAL GAS COMPRESSORS


COMPANY NAME/SITE LOCATION  TRANSWESTERN PIPELINE CO.,  RED  BLUFF ST*                  NEAR  ROSWELL,  NM


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE  OF PERMIT ISSUANCE—  05/03/82
PERMIT NO. NM-414-M-1                                                                          ESTIMATED  DATE OF  START-UP—    1982
DETERMINATION MADE BY       AIR QUALITY BUREAU -  NMEID      SHANKAR ANANTHAKRISHNA              (505)-984-0020
                             (AGENCY)                  (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION  LIMITS                                    . . . &  BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT  OR  PROCESS  MODIFICATION  ... PCT EFF


ENGINE, I.C. COMPRESSOR            2647.00 HP
                                                           NOX        4.0000  G/HP-H
                                                                            LOW NOX ENGINE


NOTES 	
STACK TEST PERFORMED, EPA REF.  METHOD 20, RESULTS — 0.82 G/HP-H
<#> INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 228
                                                                                                      INITIAL  REVIEW   POST STARTUP
                                                                                         REVIEW  STATUS:   o<;/oi/i?33
ID NUMBER NM-0010C
                                                     SO'J^CE TYPE CCOE    Z.Z

-------
                                            APPENDIX -- DETAILED SOURCE  LISTING
                                                                                                                        05/22/1934
SOURCE TYPE/SIZE---
                            NATURAL GAS COMPRESSORS
COMPANY NAME/SITE LOCATION  TRAHSWESTERN PIPELINE CO., RED BLUFF ST*
                                                NEAR ROSWELL, NM
DETERHINATION IS BACT FOR A MODIFIED SOURCE.
PERMIT NO. NM-415-M-1
DETERMINATION MADE BY       AIR QUALITY BUREAU  - NMEID     SHANKAR  ANANTHAKRISHNA
                             (AGENCY)                   (AGEN'CY  CONTACT  PERSON)
                                                         DATE OF PERMIT ISSUANCE—  05/03/82
                                                         ESTIMATED DATE OF START-UP--   1932
                                                         (5051-934-0020
                                                             (PHONE )
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
. ..  8  BASIS
. ..  PCT  EFF
ENGINE, I.C. COMPRESSOR
                                   25S5.CO  HP
                                                          NOX
                                                                     5.0000  6/HP-H
                                                                            LOW  NOX  ENGINE
NOTES 	
STACK TEST PERFORMED, EPA REF.  METHOD 20,  RESULTS  --  3.2 6/HP-H
(#> INDICATES DATUM WAS TRUNCATED FOR  THIS  TABLE.

PAGE G- 229
                                                                INITIAL REVIEW  POST STARTUP
                                                   REVIEW STATUS:   04/01/1933
                                                     ID NUMBER NM-0010D
                                                                                                           SOURCE  TYPE  CODE    3.2

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                         05/22/1984



SOURCE TYPE/SIZE	         NATURAL GAS COMPRESSORS


COMPANY NAME/SITE LOCATION  TRANSHSTERN PIPELINE CO., MALJAMAR STAT*                 NEAR MALJAMAR, MM


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE--  05/03/82
PERMIT NO. NM-387-M-1                                                                          ESTIMATED  DATE OF  START-UP—   1932
DETERMINATION MADE BY       AIR QUALITY BUREAU - NMEID     SHANKAR ANANTHAKRISHNA              (5051-984-0020
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    . . .  « BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS  MODIFICATION  ...  PCT EFF
_ ___,— .. ____.._ ____ __ » _ __ __.. — _ -» ___.._.___.. _ — _____• — — •____•-«•__ — __™ — — — __._ — —.-.» — _ — — — — — — — — — ™ — — •- — — — — — — — — — — — • — — —••- — ---- — — — — — — •-•-- — — — — — — •'•- — — — ••»'•-• — ••

ENGINE, I.C. COMPRESSOR            1073.00 HP
                                                           NOX       5.0000 G/HP-H
                                                                            LOW NOX ENGINE


NOTES 	
STACK TEST PERRFORMED, EPA RREF. METHOD 20, — RESULTS - 3.93 G/HP-H
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 230
                                                                                                       INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW  STATUS:   04/01/1903
ID NUM3ER NM-0011
                                                     SOURCE  TYPE  CODE     3.2

-------
                                            APPENDIX -- DETAILED SOURCE LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE	         NATURAL GAS COMPRESSORS                                         3000.00 HP


COMPANY NAME/SITE LOCATION  VALERO TRANSMISSION CO.                                      OLD OCEAN, TX
                                                                                                                   BRAZOPIA  COUNTY
DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF  PERMIT  ISSUANCE—   09/09/82
PERMIT NO. X-3603                                                                             ESTIMATED  DATE  OF  START-UP--    1982
DETERMINATION M^DE BY       TEXAS ACB                     RANDY HAMILTON                      (512)-451-5711
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT         POLLUTANT    EMISSION  LIMITS                                    ... 8  BASIS
TO THIS PERMIT                         CAPACITY           EMITTED            CONTROL EQUIPMENT  OR  PROCESS  MODIFICATION  ... PCT EFF


GAS COMPRESSORS, 3                 1000.00  HP  EA
                                                          NOX       34.8000 T/YR
                                                          CO        64.4000 T/YR
                                                          VOC       0.7000 T/YR


NOTES 	
GAS TURBINES INHERENTLY CLEAN-BURNING WITH  RESPECT TO NOX EMISSIONS. EMISSIONS OF NOX BASED ON 1.2  G/HP-H
                                                                                                      INITIAL REVIEW  POST STARTUP
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEW  STATUS:   04/01/1933

PAGE G- 231                                           ID  NUIIEER  TX-C1Q4                                     SC'JPCE TYPE CODE    3.2

-------
                                             APPENDIX — DETAILED  SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE—-         NATURAL GAS COMPRESSORS


COMPANY NAME/SITE LOCATION  WESTAR TRANSMISSION CO.                                               ,  TX
                                                                                                                     POTTER COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE  OF PERMIT ISSUANCE--  12/07/82
PERMIT NO. X-3990                                                                              ESTIMATED  DATE OF  START-UP—   19£2
DETERMINATION MADE BY       TEXAS ACS                      RANDY HAMILTON                      (512J-451-5711
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION  LIMITS                                    ...  4 BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT  OR  PROCESS  MODIFICATION  ...  PCT EFF


SUPERIOR 8GTLA                     1100.00 HP
                                                           NOX       21.2000  T/YR
                                                                            CCM3USTION  CHAMBER MODIFICATION
                                                           CO        21.2000  T/YR
                                                           VOC        7.9000  T/YR


NOTES 	
EMISSION LIMITS ARE 2.0 G/HP-H NOX, 2.0 G/HP-H  CO,  0.75  G/HP-H VOC.














                                                                                                      INITIAL k^.VIEW   POST  STARTUP
(*) INDICATES DATUM WAS TRUNCATED FCR THIS TABLE.                                        REVIEW STATUS:   05/04/19S4

PAGE G- 232                                           ID  NUMBER TX-0134                                    SO'J"CE T1PE CCDE    3.2

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/23/1984



SOURCE TYPE/SIZE-—         OTHER INTERNAL  COMBUSTION


COMPANY NAME/SITE LOCATION  ARGO PETROLEUM,  FERNDALE LEASE                                         , CA


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE--  09/30/83
PERMIT NO. 03SO                                                                               ESTIMATED DATE OF START-UP--
DETERMINATION MADE BY       VENTURA COUNTY                 KEITH DUVAL                         (805 )-65^-2664
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... &  BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT  EFF


I.C. ENGINE, NATURAL GAS            200.00  HP
                                                          NOX      50.0000 PPM
                                                                           CATALYTIC REDUCTION                               96.70


NOTES 	
STATE FILE 8 A330-031
(*) INDICATES DATUM WAS TRUNCATED FOR  THIS  TABLE.

PAGE G- 233
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS:
                                                     ID NUMBER CA-0074
                                                                                                          SOURCE  TYPE  CODE     3.3

-------
                                             APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                         05/22/1984



SOURCE TYPE/SIZE	         OTHER INTERNAL COMBUSTION                                         540.00  MW
                           __ — _-.—._____________._..—. — — — — — _____________,-,• _ — _«._^.__ —— _______ — — — —. — — ________ — — —.-, — — _.__ — _ __ _ — ______________ _

COMPANY NAME/SITE LOCATION  CAJUN ELECT. POWER COOP.                                     NEW  ROADS,  LA
                                                                                                                POINTE COUPE PARISH
                           „ __ __________.» ______ _ — _____ _ — «._______.___ — — — — ______ — _ — ___ — _•. — ... — ____ __ ______.»•____ — .— ______—. — .— _.-_ — __ — _ — .•-__

DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE  OF PERMIT  ISSUANCE—  03/30/78
PERMIT NO. (REGION FILE NO.) FSD-LA-062                                                        ESTIMATED DATE  OF  START-UP--
DETERMINATION MADE BY       EPA REGION VI                  JOHN BUNYAK                         (214J-767-15Q4
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... 4 BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ... PCT EFF


TURBINE> COAL FIRED                 540.00 MW
                                                           S02
                                                                            LOW SULFUR WESTERN COAL
                                                           Ptl


NOTES		
(*> INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 234
                                                                                                       INITIAL  REVIEW  POST STARTUP
                                                                                         REVIEW  STATUS--   04/01/1933
ID NUMBER LA-0001
                                                     SO'J^CE  TYPE  CODE
                                                                          3.3

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/28/1984



SOURCE TYPE/SIZE—         OTHER  INTERNAL COMBUSTION                                       6000.00 KW


COMPANY NAME/SITE LOCATION  CITY OF  AUGUSTA                                                AUGUSTA, KS
                            (MUNICIPAL  ELECT. SYS, PLANT *                                                           BUTLER COUNTY


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF  PERMIT  ISSUANCE—   05/29/81
PERMIT NO.                                                                                    ESTIMATED DATE  OF START-UP-
DETERMINATION MADE BY       EPA REGION  VII                 STEVE KOVAC                         (S16 )-37
-------
                                             APPENDIX  — DETAILED SOURCE  LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE---         OTHER INTERNAL COMBUSTION                                      18611.00 HP


COMPANY NAME/SITE LOCATION  CITY OF KINSMAN                                               KINGMAN, KS 67068
                            P.O. BOX 168                                                                           KINGMAN COUNTY


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT  ISSUANCE—  03/01/83
PERMIT NO.                                                                                    ESTIMATED DATE  OF START-UP—    1983
DETERMINATION MADE BY       EPA REGION VII                CHARLES WHITMORE                    (816>-374-6525
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHCNE )



PROCESSES SUBJECT                     THROUGHPUT       POLLUTANT     EMISSION  LIMITS                                    ... & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... FCT EFF


1C ENGINE, DUAL FUEL, UNIT 8       3495.00 HP
                                                          NOX    1150.0000 PPMV,  15X 02, DRY                                BACT
                                                                           EFFICIENT OPERATION OF THE UNIT


NOTES 	
THE UNIT, A COOPER-BESSEMER MODEL LSV-12-GDT, WAS  PREVIOUSLY OPERATED SINCE 1963 BY ANOTHER MUNICIPAL UTILITY. TO ENSURE  THAT
S02 EMISSIONS WILL NOT INCREASE BY A "SIGNIFICANT" AMOUNT,
THE AMOUNT OF DISTILLATE FUEL OIL WHICH MAY BE COMBUSTED IS LIMITED TO 10X OF  THE  TOTAL ANNUAL HEAT INPUT FOR  THE UNIT.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 236
                                                                                                     INITIAL REVIEW  POST STARTUP
                                                                                        REVIEW STATUS:  04/01/19S3
ID NUMBER KS-0017
                                                     SOLACE TYPE CODE
                                                                         3.3

-------
                                            APPENDIX  — DETAILED SOURCE  LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE—         OTHER INTERNAL  COMBUSTION                                       16624.00  HP (TOTAL,  TO BE AD*


COMPANY NAME/SITE LOCATION  CITY OF OTTAWA                                                   OTTAWA,  KS
                                                                                                                   FRANKLIN COUNTY
                           «.«._—. — ______ — ___,. __ — _ ____ — ....___ — ____ _ _ __ — » «.__>. «.___« ___.._ __ __,- — __,• — — —. — ,. — — — — — •- — — -• — — — — — —— — — — — —*- — — — — — — — — — — —

DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE  OF PERMIT ISSUANCE—  12/02/80
PERMIT NO.                                                                                     ESTIMATED DATE OF START-UP—   1980
DETERMINATION MADE BY       EPA REGION VII                  STEVE KOVAC                          <816)-374-6525
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION LIMITS                                   ... & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL  EQUIPMENT OR PROCESS MODIFICATION  ... FCT EFF


RECIP. ENGINES, 2 DUEL-FUEL 1C,*   6000.00  KW EA
                                                           NOX    1150.0000 PPM  15X  02 (D)                                   BACT
                                                           S02               FUEL STANDARD
                                                                            S IN FUEL LIM. TO  0.5X BY WT.


NOTES 	
(«) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 237
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW STATUS;  04/01/1933
ID NUMBER KS-0004
                                                     SOURCE TYPE CODE    3.3

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                         05/22/1934



SOURCE TYPE/SIZE—-         OTHER INTERNAL COMBUSTION                                         90.00 MW


COMPANY NAME/SITE LOCATION  EMPIRE DIST. ELECT. CO.                                               , MO
                            LARUSSELL STATION                                                                      LAKSENCE COUNTY
                           	—	•	—	—	— —	—	_ — ___,._	_____	__	_«.__..______	_.„._.__,,	„«.	„ _		„_

DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE—  01/07/81
PERMIT NO.                                                                                     ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY       EPA REGION VII                 DANIEL RODRIGUEZ                    (816)-374-6525
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT 03 PROCESS MODIFICATION  ... PCT EFF


COMBUSTION TURBINE, SIMPLE-CYC,*   1056.00 MMBTU/H (MA*
                                                           NOX     330.0000 PFMV, 15X 02, (ISO)-STAK'D. DAY COND.             BACT
                                                                            DESIGN
                                                           CO       56.0000.LB/H                                             BACT
                                                                    21.0000 FFfiV
                                                           S02              FUEL STANDARD
                                                                            SEE NOTE


NOTES 	
THE UNIT IS NOT SUBJECT TO NSPS, SUBPART GG. THE 7. 5 CONTENT OF THE FUEL TO BE BURNED IN UNIT 2 IS LIMITED BY PERMIT CONDITION
S TO 0.8X, BY UT. THE NOX AND CO/EACT LIMITS WERE DERIVED FROM INFO.  PROVIDED BY THE TURBINE MANUFACTURER.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 233
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS:  04/01/19S3
                                                      ID  NUMBER MO-0.001
                                                                                                           SOURCE TYPE CCOE
                                                                                                                               3.3

-------
                                            APPENDIX  — DETAILED SOURCE  LISTING
                                                                                                                        05/23/1934
SOURCE TYPE/SIZE—-
                            OTHER INTERNAL COMBUSTION
                                                                                             252.00 MW
COMPANY NAME/SITE LOCATION  FLORIDA POWER
                                 AVON PARK, FL 33733
                                                                                                                  HIGHLANDS COUNTY
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT NO. FL 017
DETERMINATION MADE BY       FLORIDA DER
                             (AGENCY)
   ED PALAGYI
(AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE—  01/21/81
                                       ESTIMATED DATE OF START-UP—    1982
                                                                                                   ( PHONE )
PROCESSES SUBJECT                     THROUGHPUT         POLLUTANT     EMISSION LIMITS                                   ... $ BASIS
TO THIS PERMIT                         CAPACITY           EMITTED             CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF


TURBINE PEAKING UNITS, 
-------
                                             APPENDIX  -- DETAILED SOURCE  LISTING
SOURCE TYPE/SIZE---         OTHER INTERNAL COMBUSTION


COMPANY NAME/SITE LOCATION  GENERAL MOTORS CORP.,  PROVING GROUNDS                          MILFORD, MI


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—  03/14/84
PERMIT NO. 27-84                                                                              ESTIMATED DATE OF START-UP—   1933
DETERMINATION MADE BY       MICHIGAN DNR                  KENNETH TERRY                       (5171-322-1333
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT         POLLUTANT    EMISSION LIMITS                                    ... & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF


DYNAMOMETER, CAR/TRUCK TESTING
                                                          VE       20.0000 7. OPACITY
                                                                           FILTER TOWER, SEE NOTE


NOTES -----------
ONLY BEIN3 USED WHEN 5 OR MORE ENGINES ARE SIMULTANEOUSLY RUNNING OR AN OPACITY PROBLEM EXISTS, OR APPROXIMATELY 1/2 HR PER DA
Y t 3 1/2 HR PER WEEK.
(*> INDICATES DATUM WAS TRUNCATED FOR  THIS TABLE.

PAGE G- 240
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS;
                                                     ID NUMBER MI-0026A
                                                                                                          SOURCE TYPE CODE    3.3

-------
                                            APPENDIX -- DETAILED SOURCE LISTING
                                                                                                                       05/22/1934



SOURCE TYPE/SIZE—         OTHER  INTERNAL COMBUSTION                                       2672.00 MMBTU/H


COMPANY NAME/SITE LOCATION  GULF STATES UTILITY                                        BATON ROUGE, LA
                            13 MI.  S.  BATON ROUGE                                                                 IBERVILLE  PARISH


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE—   01/30/81
PERMIT NO. (REGION FILE NO.) PSD-LA-292                                                        ESTIMATED DATE OF START-UP--
DETERMINATION MADE BY       EPA REGION VI                  JOHN BUNYAK                         <214)-767-1594
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                    ... & BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT  EFF
COMBUSTION TURBINE(2)
                                   1336.00 MMBTU/H
                                                          S02       5.5000 LB/H
                                                                    0.0040 LB/MMBTU GAS
                                                                           NATURAL GAS FIRING
                                                          NOX     334.0000 LB/H
                                                                    0.2500 LB/MMBTU GAS
                                                                           STEAM/WATER INJECTION
                                                          CO      125.0000 LB/H
                                                                    0.0900 LB/MMBTU GAS
                                                                           COMBUSTION CONTROLS
                                                          PM        1.0000 LB/H
                                                                    0.0010 LB/MMBTU GAS
                                                                           NATURAL GAS FIRING
                                                          S02     296.0000 LB/H
                                                                    0.2200 LB/M;:BTU OIL
                                                                           .23X S. FUEL OIL
                                                          NOX     362.0000 LB/H
                                                                    0.2700 LB/MMBTU OIL
                                                                           STEAM/WATER INJECTION
                                                          CO      216.0000 LB/H
                                                                    0.1600 LB/MMBTU OIL
                                                                           COM3USTION CONTROLS
NSPS


NSPS


BACT


BACT


NSPS


NSPS


BACT
PAGE G- 241

-------
                                                           PM       33.0000 LB/H                                             8ACT
                                                                     0.0250 LB/MM8TU OIL
                                                                            .IX ASH FUEL OIL
NOTES 	
TWO COMBUSTION TURBINES ARE PERMITTED TO FIRE EITHER NATURAL GAS OR FUEL OIL.
                                                                                                     INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR  THIS TABLE.                                        REVIEW STATUS:  04/01/1983
PAGE G- 242                                          ID NUMBER LA-0005                                    SOURCE TYPE CODE    3.3

-------
                                            APPENDIX ~ DETAILED SOURCE LISTING
                                                                                                                       05/22/1984



SOURCE TYPE/SIZE—-          OTHER  INTERNAL COMBUSTION                                        100.00 MM


COMPANY NAME/SITE LOCATION  GULF STATES UTILITY                                       LAKE CHARLES, LA
                            6  MI WNW OF LAKE CHARLES                                                              CALCASIEL PARISH


DETERMINATION IS BACT FOR  A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE—  12/22/80
PERMIT NO.  (REGION FILE NO.) PSO-LA-29<+                                                        ESTIMATED DATE OF START-UP--
DETERMINATION MADE BY       EPA REGION VI                  JOHN BUNYAK                         (214)-767-1594
                            (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                    THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... * BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... FCT EFF
TURBINE
                                   1396.00 MMBTU/H
                                                          S02       0.3500 LB/MMBTU OIL
                                                                    0.0010 LB/MM3TU GAS
                                                                           LOM SULFUR OIL (0.46X)
                                                          NOX       0.2600 LB/MM3TU OIL
                                                                    0.2500 LB/KM3TU GAS
                                                                           WATER/STEAM INJECTION
                                                          CO        0.1600 LB/MM3TU OIL
                                                                    0.0900 LB/MM3TU GAS
                                                                           EFFICIENT DESIGN
                                                          PM        0.0900 LB/MMBTU OIL
                                                                    0.0010 LB/flKBTU GAS
                                                                           LOU ASH OIL (0.1X)
                                                                                                                            NSPS
                                    NSPS

                                    60.00
                                    BACT
                                    BACT
NOTES
(*) INDICATES DATUM WAS TRUNCATED  FOR THIS TABLE.

PAGE G- 243
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS:  04/01/1?33
                                                     ID NUMBER LA-0003
                                                                                                          SOURCE TYPE COOE
                                                                                                                              3.3

-------
                                             APPENDIX  — DETAILED SOURCE  LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE—-         OTHER INTERNAL COMBUSTION                                          23.30 MKW


COMPANY NAME/SITE LOCATION  HOFFMANN-LAROCHE, INC.                                        BELVIDERE, NJ  07823
                            MAMUNKACHUNK AVENUE                                                                       WARREN COUNTY


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE OF  PERMIT ISSUANCE--  08/17/81
PERMIT NO.                                                                                     ESTIMATED  DATE OF  START-UP-
DETERMINATION MADE BY       EPA REGION II                  LARRY KARAS                          (212 )-264-953S
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT       POLLUTANT    EMISSION  LIMITS                                    .. .  « BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT  OR  PROCESS  MODIFICATION  ...  PCT EFF
— — - *	—	•	— ——-.— ——_	— _	_	— _ —	_	„.	__	__	«._ _	_	_,_	__..	_	— —__.».._	— -,	..__	_ _:	.._	—___.._	___	_	__-.•.	— — —

DIESEL ENGINE, W/WASTE HEAT BOI*     23.30 MKW
                                                          NOX    2272.0000 T/YR                                              NSPS
                                                                           WASTE HEAT BOILER
                                                                           RETARD. FUEL  INJ.  TIMING


NOTES —	-
SPECIFIC LIMITATIONS IN TERMS OF CAPACITY SHALL  BE MET (AS PERMIT CONDITIONS)  FOR THE OPERATION OF  THE  DIESEL COGENERATION  FAC
ILITY IN COMBINATION WITH SOME OF THE FIVE EXISTING BOILERS.
<*) INDICATES DATUM WAS TRUNCATED  FOR  THIS TABLE.

PAGE G- 24<+
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS;  0^/01/1933
                                                     ID NUMBER NJ-0003
                                                                                                          SO'J°CE TYPE CODE
                                                                                                                              3.3

-------
-

UJ
0
g
o
V)
£
z
3
O
u

z
o

M
o

E













r -f
H


a
UJ
>
M
a

o

o









































•
(_j

M

O

*»

a:

01

O
i
3
M
^


Z
M
f—

8
_j

UJ
t-
M
in
X
UJ
E
<
Z
>-
Z
<
D-
E
O
U
in
o-
rH



i
i
a
1 3
i i
UJ t-
O Q:
Z <
< t-
3 W
in
in u.
M O

f- UJ fl
M H rH
E < rH
DC D CM —
Ul 1 UJ
O- O CM Z
Ul CO O
U, r- N I
O -
[y ^_J
X 2
U UJ
is


















<(
* a.
LU UJ
U ~

§M O
o z:
*/> i: LU
M CD
U) -J ^
2 M

^

g


H- rH >-
O CJ UJ
< 0
03 O LU
O
in r^ <
M 0 E

Z CM Z
O <0 O
M M
H • r-
< O <
z z z
M M
E »- r
D: M a;
UJ 3- uj
1- o: r-
UJ UJ UJ
o a. o
n
n
n
n
u
u
n
n
n
n
n
it
n
u
it
n
n
it
u
n
n
n
n
ii
n
n
n
n
ii
ii
11
n
n
it
it
n
u
it
n
n
n
ii
n
n
n
n
u
ii
n
ii
n
n
ii
n
ii
M
II
II
II
It
II
II
II
II
II
II
II
II
II
II
II
It
II
It
II
II
II
Jj
11
II
II
II
II
II
II
II
II
11
II

II
II
II
II
II
II
II
It
II
II
II
II
II
II
II
II
II
II
II
II
II
II
II
II
U
II
II
II
II
II
II
II
II
II
II
II
II
II
11
II
M U.
in LU
^
10 r-
U
•a a

( •
, ,
. .


Z
o
M

^
U
M
U.
M
O
g

in

UJ
o
0

fl

o:
o

r-

UJ
r:
a.
M

cr
Ul

i 	 1
M O

M r-
-J Z
O
Z 0
o
M
in
in
M
E
Ul




lEa
< Ul

ID f—
_J M
— J 3C
O LU
a.








f~
D >
a H
3Z H
CD U

o a.

-£ (J
r~


















r-
o
UJ
-> t-

3 3T
in D;
UJ
in a.
UJ
in tn
in M
UJ I
o >-
o
a: o
a K
in 10
D. n.
in in
Z Z





















in w
^ ^
10 ID

1- 1-
U O
3 3
O O
o o
C£ [X
n Q_
Z
U. U- ID
O O M
w
Z Z UJ
O O Q
M M
(-(-!-
< < z
O U UJ
M M z:
u. u- a.
M M I M
E K E a X D
Q. 3 a. 3 fl3 Gf
a. u, a. CL -i ui

o o o
O 0 0
O 0 O
o o o
• * *
O LA O
in r^ o-
rH CM




CM X
0 0 O
in z u


































o
Ul
a:
M
u.

in

0

t
^
o
o

UJ
z
M
1
r-
     O
     or
     LL
     o
     E
     UJ
     a

     o
     in
     ID
     o
     u
a.
UJ
a.

o
o
M
M
O
o
in
10
    M
    D:
    ID
    O
    a:
    o.
    UJ
    E
    a.
    x
    UJ
    z
    M

    O
    Ul
    in
    e
in  M   .
ui  tn t-
t-  <* o
                                                 3     II   •
                                                 f-     n  to
                                                 CK     II
                                                 <     II
                                                 t-     II
                                                 V)     II
                                                        II  UJ
                                                 H     HO
                                                 in     no
                                                 O     II  LJ
                                                 QL     II
                                                        II  Ul
                                                        ii  a.
                                                 3     n  v
                                                 UJ IO II  f-
                                                 M CO II
                                                 > O' II  Ul
                                                 LU rH II  U
                                                 a x ii  CK
                                                    rH II  D
                                                 .J O II  CJ
                                                 «t x n  10
                                                 M ~S- II
                                                 r- O II
                                                 M     II
                                                 Z     II
                                                 M ••  II
                                                    in n
                                                    3 II
                                                    H- II
                                                    < II
                                                    K II
                                                    in n
                                                        n
                                                        >  II
                                                        UJ  II
                                                        EX  II
                                                             II
                                                             II
                                                             II
                                                             II
                                                            II
                                                            II
                                                            II
                                                            II
                                                            II
                                                            It
                                                            II
                                                            II
                                                            II
                                                            II
                                                            II
                                                            II
                                                            It  O
                                                            II  rH
                                                            II  O
                                                            II  O
                                                            II   I
                                                            II  —I
                                                            II  M
                                                            II
                                                            II  tX.
                                                            II  UJ
                                                            ii  rn
                                                        CD  u
                                                        <  n
                                                        t-  ii
                                                            n
                                                        in  n
                                                        M  II
                                                   in it
                                                   UJ It
                                                   t- II  Ul
                                                   < II  J-
                                                   U II  CJ
                                                   M II
                                                   p II   I
                                                   2 ii  10
                                                   M II
                                                       II  UJ
                                                   — II  ID
                                                   *  II  <
                                                   •^ ii  a.

-------
                                             APPENDIX  —  DETAILED  SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE—         OTHER INTERNAL COMBUSTION


COMPANY NAME/SITE LOCATION  MUNICIPAL GENERATING PLANT                                      BELOIT, KS
                           — _ —	___,-_	_	—	—	— ___	____-._ — _ — —_ — ._	_-,_ — -._ — — __.,_.._.- — _ — —_.._ — _ — — — — — — — _	_-.__..	______,,_

DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE OF PERMIT ISSUANCE-
PERMIT NO.                                                                                     ESTIMATED DATE OF START-UP—
DETERMINATION MADE BY       EPA REGION VII                STEVE KOVAC                         (816)-374-6525
                             (AGENCY)                  (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT       POLLUTANT     EMISSION LIMITS                                   ... & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF


ENSINE-GENERATOR                   6000.00 KW
                                                          NOX     1150.0000 PPMV 15'/. 02, DRY BASIS
                                                          S02               FUEL STANDARD
                                                                            S CONTENT LIM. TO 0.7X BY WT.
                                                          CO


NOTES 	
TEST DATA USED TO ESTABLISH NOX STANDARD
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 246
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW STATUS:  04/01/1933
ID NUMBER KS-001^
                                                     SOURCE TYPE CCOE
                                                                          3.3

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE-—         OTHER  INTERNAL COMBUSTION                                        250.00 MW


COMPANY NAME/SITE LOCATION  NEVADA PWR CO./REID GARDNER STATION                              MOAPA, NV


DETERMINATION IS BACT FOR A MODIFIED  SOURCE.                                                   DATE OF PERMIT  ISSUANCE—  01/03/80
PERMIT NO. (REGION FILE NO.) NV 79-03                                                         ESTIMATED DATE  OF  START-UP—    1983
DETERMINATION MADE BY       EPA REGION IX                  JIM HANSON                          (415)-974-8038
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                    THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ...  & BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ...  PCT EFF


GENERATOR                          250.00 MM
                                                          S02       0.2900 LB/MMBTU
                                                                           WET SCRUBBER                                      85.00
                                                          NOX       0.5000 LB/MI1BTU S3. COAL
                                                                    0.6000 LB/MM8TU BIT. COAL
                                                                           PROPER BOILER DESIGN &  OPER.
                                                          PM        0.0300 LB/MM3TU
                                                                           BAGHOUSE                                          99.60


NOTES 	
ALL EMISSION LIMITS ARE BASED ON:  NSPS,  AND BACT DETERMINED BY TECHNOLOGY ANDECONIMICS. ADDITION OF GENERATOR  TO  AN EXISTING F
ACILITY.
(*) INDICATES DATUM WAS TRUNCATED FOB THIS  TABLE.

PAGE G-
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW STATUS;   04/01/1933    02/13/1934
ID NUMBER NV-0004
                                                     SCU.7CE TYPE CODE
                                                                         3.3

-------
                                             APPENDIX -- DETAILED SOURCE LISTING
                                                                                                                        05/22/1934



SOURCE TYPE/SIZE—         OTHER INTERNAL COMBUSTION                                          4.20 (1MCF/YR


COMPANY NAME/SITE LOCATION  ORGANIC FUEL PRODUCTION,  INC.                                          , TX
                                                                                                                    LUBBOCK COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—  02/16/83
PERMIT NO. X-4141                                                                              ESTIMATED DATE OF START-UP—   1983
DETERMINATION HADE BY       TEXAS ACB                      GARY WALLIN                         t512)-451-5711
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   . . .  t BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ...  PCT EFF
	-------«--..-.--•	

DIGESTERS, 7                          4.20 MMCF/YR
                                                           PM         0.0100 T/YR
                                                           S02        0.0020 T/YR
                                                                            IRON SPONGE
                                                           NOX        0.2100 T/YR


NOTES 	















                                                                                                      INITIAL REVIEW  POST  STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEW STATUS:   05/04/1934

PAGE G- 248                                           ID NUMBER  TX-0113                                     SOLTCE  TYPE CCDE    3.3

-------
                                            APPENDIX ~ DETAILED SOURCE  LISTING
                                                                                                                        05/22/1934



SOURCE TYPE/SIZE—         OTHER INTERNAL COMBUSTION                                         160.00 MHP


COMPANY NAME/SITE LOCATION  PRUDHOE BAY CONSORTIUM                                      PRUDHOE BAY, AK
                           — — — — — — — — — — — — — — — — — — — — • — — — — — — — — — — — — — — — — — — — — -. — — — — — — — — — — __ — — _ — — •_ — — __ — »_ — — _.„ — •„__ — ___._,.•_._._ — .•____.«_•_.__,____..,_

DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE OF PERMIT ISSUANCE—  12/17/80
PERMIT NO. (REGION FILE NO.) PSD-X81-13                                                        ESTIMATED DATE OF START-UP--
DETERMINATION MADE BY       EPA REGION X                  PAUL BOYS                            (2061-442-1193
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF


GAS TURBINE, 10                      16.00 MHP EA
                                                          NOX     150.0000 PPM                                               BACT
                                                                           DRY  CONTROLS
                                                          CO      109.0000 LB/MMSCF FUEL                                     BACT
                                                                           MONTGOMERY  PROPER COMBST.  COND.
GAS HEATERS
                                                          NOX       0.0800 LB/MMBTU                                          BACT
                                                                           LOU  NOX BURNERS
                                                          CO        0.0180 LB/MMSTU
                                                                           MONTGOMERY  PROPER COMBST.  COND.


NOTES 	











                                                                                                      INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:  04/01/1983

PAGE G- 249                                          ID HUTSER AK-OOC3                                     SC'J~CE TYPE CODE    3.3

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/23/1984



 SOURCE TYPE/SIZE---         OTHER INTERNAL COMBUSTION
                           	

 COMPANY NAME/SITE LOCATION  SEA WORLD, INC.                                              SAN DIEGO,  CA 92109
                            1720 SOUTH SHORES RD.


 DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE  OF PERMIT ISSUANCE-  06/11/82
 PERMIT NO. 7801                                                                                ESTIMATED DATE OF START-UP--   1981
 DETERMINATION MADE BY       SAN DIEGO APCD                 GUS  ANDERSON                        (6191-565-3925
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



 PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ...  « BASIS
 TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ...  PCT EFF
 	

 I.C. PISTON ENGINE                    7.10 MM3TU/H
                                                           NOX        1.8000  LB/MHBTU SEE  NOTE
                                                                            SINGLE  STAGE  CATALYTIC CONVERT.
                                                           CO         1.5000  LB/MMBTU SEE  NOTE
                                                                            SINGLE  STAGE  CATALYTIC CONVERTER


NOTES 	
COSENERATION UNIT CONSISTING OF 930 BMP I.C.  PISTON ENGINE, NATURAL GAS FUELED, 630 KW  ELECTRIC GENERATOR  AS!D EQUIPPED  FOR  WAS
TE HEAT RECOVERY.
BEFORE USING THE EMISSION UNITS SHOWN, THE SAN  DIEGO AGENCY SHOULD BE CONTACTED.
(*> INDICATES DATUM HAS TRUNCATED FOR  THIS  TABLE.

PAGE G- 250
             INITIAL P*cVIEW  POST STARTUP
REVIEW STATUS:  04/01/19S3
                                                     ID NUMBER CA-0042
                                                                                                          SOURCE TYPE CODE
                                                                                                                               3.3

-------
                                             APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                         05/22/1984



SOURCE TYPE/SIZE—         OTHER INTERNAL COMBUSTION
                            — — —— — — — — — — —. — — — -... — — — _«..._. __ «. _ .__ __ •...•»„»„_ _«.«.„__ •••«.„.»„....»•,.»_ __..____.__..•..„ — __« ________ _«.»__fcfc,ii»^™«-.«,«,^ — «••«_«•._

COMPANY NAME/SITE  LOCATION  SEA WORLD, INC.                                               SAN DIEGO,  CA 92109
                            1720 SOUTH SHORES RD.
                            	_	

DETERMINATION IS BACT FOR A NEW SOURCE.                                                         DATE  OF PERMIT ISSUANCE--  05/12/83
PERMIT NO. 8134                                                                                 ESTIMATED DATE OF START-UP--   1983
DETERMINATION MADE BY       SAN DIEGO APCD                 GUS ANDERSON                         (619J-565-3925
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... 4 BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF


I.C. PISTON ENGINE                    7.10 MMBTU/H
                                                           NOX       0.2480 LB/MMBTU
                                                                            2 STAGE CATALYTIC CONVERT.                       90.00
                                                           CO        0.2300 LB/Mr'.BTU
                                                                            2 STAGE CATALYTIC CONVERTER                      90.00


NOTES 	
COGENERATION UNIT CONSISTING OF 930 BHP I.C.  PISTON ENGINE, NATURAL GAS FUELED,  630 KM  ELECTRIC GENERATOR Af!D EQUIPPED FOR WAS
TE HEAT RECOVERY. PERMIT PENDING
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 251
             INITIAL REVIEW   POST  STARTUP
REVIEW STATUS;  04/01/1933
                                                      ID NUMBER CA-004CA
                                                                                                            SOU3CE TYPE CODE
                                                                                                                                3.3

-------
                                             APPENDIX  — DETAILED SOURCE  LISTING
                                                                                                                        05/32/1934



SOURCE TYPE/SIZE	         OTHER INTERNAL COMBUSTION                                         40.00 MW


COMPANY NAME/SITE LOCATION  SEBRING UTILITIES COMMISSION                                   SEBRING, FL 33870
                            368 S. COMMERCE AVE.  P.O.  BOX*                                                        HIGHLANDS COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE--   04/03/81
PERMIT NO. (REGION FILE NO.) PSD-FL-071                                                        ESTIMATED DATE OF START-UP—    1983
DETERMINATION MADE BY       FLORIDA DER                    ED PALAGYI                          (9041-428-1344
                             (AGENCY)                  (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                    ... & BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF
DIESEL ENGINES
                                     19.53 MW  EA
                                                          NOX     819.0000 PPMV
                                                                           COMBUSTION CONTROL
                                                          S02        2.6700 LB/MHBTU
                                                                           Z.57. SULFUR OIL
                                                          PM         0.1000 LB/MMBTU
                                                                           COMBUSTION CONTROL
                                                          CO         0.5750 LB/MMBTU
                                                                           EQUIPMENT OPERATION
                                                          VOC        0.2600 LB/KMBTU
                                                                           EQUIPMENT OPERATION
                                                                       NSPS

                                                                       BACT

                                                                       BACT

                                                                       NSPS

                                                                       NSPS
NOTES 	
HU3E SLOW-SPEED RECIPROCATING INTERNAL COMBUSTION  ENGINES TO DRIVE ELECTRICAL GENERATORS.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 252.
                                                                                                     INITIAL REVIEW  POST STARTUP
                                                                                        REVIEW STATUS:  04/01/1933    01/25/1934
ID NUMBER FL-0025
                                                     SOURCE TYPE CODE
                                                                         3.3

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                         05/23/1984



SOURCE TYPE/SIZE—-         OTHER INTERNAL COMBUSTION                                         27.50 MMCFD
                           — — — — — — —	—	— — —	— — — — — _ — ».-.—. — __ — ».______	-, — __ — »._«.	_______	__	_•.«»..__»•.__...,__ ».»~ —„••«».-_ — ____.,____

COMPANY NAME/SITE LOCATION  SHELL OIL CO.                                             NEAR MCCAMEY, TX
                                                                                                                       UPTON COUNTY
                           	—	.	.	

DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE—  03/27/81
PERMIT NO. (REGION FILE NO.) PSD-TX-360                                                        ESTIMATED DATE OF START-UP—   1981
DETERMINATION MADE BY       EPA REGION VI                  BILL TAYLOR                         (214)-767-1594
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ...  t BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ...  PCT EFF


I.C. ENGINES, RECIPROCATING FUE*   1215.00 HP
                                                           NOX      10.0000 G/HP-H                                            BACT
                                                                            DERATED OLD ENGINES


NOTES 	
(*) INDICATES DATUM MAS TRUNCATED FOR THIS TABLE.

PAGE G- 253
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS:  04/01/1983
                                                      ID NUMBER TX-0030
                                                                                                           SCX'SCE TYPE CODE     3.3

-------
                                             APPENDIX --  DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE	         OTHER INTERNAL COMBUSTION                                      12000.00 KW


COMPANY NAME/SITE LOCATION  TRENTON DISTRICT ENERGY CO.                                     TRENTON, NJ
                            S. WARREN BET. LIVINSSTON * F*                                                           MERCER COUNTY
                           ____„_________„___„___„_______._______,___»__„___«____ — _ — __ —— __^ ——._ — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —

DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE--  10/29/81
PERMIT NO.                                                                                     ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY       EPA REGION II                  LARRY KARAS                         (212)-264-953S
                             (AGENCY)                  (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT       POLLUTANT    EMISSION LIMITS                                   . . . t. BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT CR PROCESS MODIFICATION  ... PCT EFF
_ _ _ ,_ ___.. _______ ». _ _ . ______ — _ _ _ _ „_ ___________________________ _-, _________ _ — •__—.».» — _•,__•>. — — __ — — — _ — — » — — — «. — — — — — — — — — — — — — — — — -. — — — — — — — —• — — — -»•• — — — —

DIESEL ENGINES, W/2 SUP. FIRED *      6.00 MKW EA
                                                           PM       71.0000 T/YR
                                                                            SUPPLEMENTARY FIRED BOILERS
                                                                            PROPER COMBST. OF EXAUST GASES
                                                           S02     432.0000 T/YR                                             SIP
                                                                            LOW SULFER FUEL
                                                                            LOU SULFUR FUEL
                                                           NOX    1869.0000 T/YR                                             DESI
                                                                            USE OF MANUFACT. ENS. MOD.


NOTES 	
GCOO COMBUSTION PRACTICE 4 USE OF LOU SULFUR FUEL OIL, 0.5X BY WT., t USE OF NATURAL GAS AS AVAILABLE,ARE REQUIRED FOR WASTE H
EAT BOILERS. BASIS FOR PM CONTROL IS CONTROL EQUIPMENT.
BASIS FOR FM CONTROL IS CONTROL EQUIPMENT








                                                                                                      INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:  04/01/1°33

PAGE G- 254                                           ID  NUMBER NJ-0002                                    SOURCE TYPE CODE    3.3

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1964



SOURCE TYPE/SIZE—         SURFACE COATING - CANS/COILS


COMPANY NAME/SITE LOCATION  BALL METAL CONTAINER GROUP                                EAST FINDLAY, OH


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE 0F PERMIT ISSUANCE—  04/10/81
PERMIT NO. 03-1025                                                                             ESTIMATED DATE OF START-UP—   1981
DETERMINATION MADE BY       OHIO EPA NKD                   DON WALTERMEYER                     (419 )-35;i-S461
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (RHONE)
PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... S BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF
•"— — -- — — — — — — — — —— — -* — — — — — ••-•- — — — — — «_ — — _ __ _ _ __ „ _ _ __ __ _„. ____„..__..,___„_,____ __ ___»_ — •__________—..-.-__—,_ —_„________.„___.»______„,___„.___„,.„_______

EXTERIOR BASE OPERATION             300.00 MM CANS/LIN*
                                                           VOC       0.3600 KG/L COATING SOLIDS                              NSFS
                                                                            THERMAL INCINERATOR                              85.00
INTERNAL COAT                       300.00 MM CANS/LIN*
                                                           VOC       0.5400 LB/GAL COATING MINUS H20                         BACT


NOTES 	
PERMIT REQUIRES THAT VOC EMISSIONS SHALL NOT EXCEED ANY NSPS LIMITS APPLICABLE TO BEVERAGE CAN SURFACE COATING. IT REQUIRES TH
E SOURCE TO NOTIFY OF 1) CONSTRUCTION DATE, 2) ANTICIPATED STARTUP DATE, 3) ACTUAL STARTUP DATE, AHO 4) DATE
OF PERFORMANCE TESTING
                                                                                                      INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         PEVIEW STATUS:  04/01/1933
PAGE G- 255                                           ID  NUMBER  OH-0035                                    SCUSCE TYPE CODE    
-------
                                             APPENDIX  —  DETAILED  SOURCE  LISTING
                                                                                                                        05/22/1934
SOURCE TYPE/SIZE—         SURFACE COATING - CANS/COILS


COMPANY NAME/SITE LOCATION  CONTINENTAL CAN CO.,  USA  PLANT  #82                      WEST CARROLLTON,  OH
DETERMINATION IS LAER FOR A NEW SOURCE.                                                         DATE OF PERMIT ISSUANCE—  07/01/S3
PERMIT HO. 0857101741                                                                          ESTIMATED DATE OF START-UP—   1933
DETERMINATION M40E BY       REGIONAL APCA                  JAMES GROSS                         (513)-225-4435
                             (AGENCY)                   (AGENCY  CONTACT PERSON)                     (PHONE)
PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... S BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
___________________ — ___ — — __•«• — — — — — »__ — __ — -.__— — — — — — — — — — — -. — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — -._ — — — — — ••. — — — — —— — •- — — — — •••"- — — — — -•• — — — — — — •"*- — — — — —


END SEAM COMPOUND                     4.70 GAL/H
                                                          VOC        3.0900 LB/GAL COMPOUND, MINUS H20                       TECH
                                                                    38.1600 T/YR


NOTES 	
PHASED INSTALLATION OF 4 LINES, 4 MACHINES EA. , WILL OCCUR IN  A  6 MONTH PERIOD. IN APRIL, 1984, CONTINENTAL CAN WILL BEGAIN EM
PLOYING A NEW END SEAM COMPOUND
WHICH WILL BE COMPOSED OF A VOC CONTENT LESS THAN 3.09  LB/GAL, MINUS WATER.
                                                                                                      INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:
PAGE G- 256
                                                      ID NUMBER OH-0047                                    SOURCE TYPE COOE    4.1

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/22/1984



SOURCE TYPE/SIZE—-         SURFACE  COATING - CANS/COILS


COMPANY NAME/SITE LOCATION  EVANS COOPERAGE CO., INC.                                        TULSA, OK


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—  05/04/83
PERMIT NO.  T82-31                                                                             ESTIMATED DATE OF START-UP—   1983
DETERMINATION MADE BY       TULSA CITY-COUNTY HEALTH DEPT  JIM VAN SANDT                       (918)-744-1000
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                    THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    . . . fc BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF


HAND SPRAY DRUM PAINTING             73.00 DRUMS/H
                                                          VOC      15.6800 LB/H
                                                                           HIGH SOLIDS PAINT,43.9X SOLIDS                   12.90


NOTES 	
1) VOC REDUCTION IN PAINTS BACT BECAUSE  OF ECONOMIC FACTOR. ANY OTHER CONTROLS WOULD HAVE COST BOX OF THE TOTAL INVESTMENT.
(*) INDICATES DATUM WAS TRUNCATED FOR  THIS TABLE.

PAGE G- 257
      INITIAL REVIEW  POST STARTUP
STATUS:  04/01/1933
                                                     ID NUMBER OK-0015
                                                                                                          SOURCE TYPE CODE    4.1

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1964
SOURCE TYPE/SIZE—-
                            SURFACE COATING - CAMS/COILS
                                                                                             600.00 MM CANS/YR
COMPANY NAME/SITE LOCATION  MILLER BREWING CO.
                                                                                          MOULTRIE, GA
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT NO. 3411-035-6906-C
DETERMINATION MADE BY       GEORGIA EPO
                             (AGENCY)
                       HAI  CHANG
                    (AGENCY CONTACT PERSON)
                                                           DATE OF PERMIT ISSUANCE--  07/02/79
                                                           ESTIMATED DATE OF START-UP--   1931
                                           ( FHCN'E )
PROCESSES SUBJECT
TO THIS PERMIT
  THROUGHPUT
   CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MCDIFICATION
« BASIS
FCT EFF
BASE COATING
INTERIOR BODY SPRAYING
OVERVARNISH
END SEALING COMPOUND
298.00 T/YR


182.00 T/YR


 76.00 T/YR


 66.00 T/YR
   VOC       1.8500 LB/GAL COATING MINUS H20
                    LOW SOLVENT COATING

   VOC       3.9900 LB/GAL COATING MINUS H20
                    LOW SOLVENT COATIS'G

   VOC       2.3300 LB/GAL COATINS MINUS H20
                    LOW SOLVENT COATING

   VOC       3.7000 LB/GAL COATIK'S MINUS H20
                    LC'.>f SOLVENT COATINS
NOTES 	
PLANT CURRENTLY DOES NOT PREFORM ANY BASE COATING OPERATION.  COMPLIANCE COATIN'35 ARE NOW BEIN3 USED FCR THE OTHER THREE COATIN
G OPERATION'S.
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 258
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW STATUS:   04/01/1933
                  ID  NUMBER  GA-0011
                                                                       scur:c£ TYPE CCCE

-------
                                            APPENDIX -- DETAILED SOURCE LISTING
                                                                                                                        05/22/1934



SOURCE TYPE/SIZE—-         SURFACE COATING  - CANS/COILS


COMPANY NAME/SITE LOCATION  NATIONAL CAN CORP.                                              CHICAGO,  IL
                                                                                                                       COOK COUNTY


DETERMINATION IS LAER FOR A NEW SOURCE.                                                         DATE  OF PERMIT ISSUANCE—  11/09/81
PERMIT NO. C 7906091                                                                           ESTIMATED  DATE OF  START-UP—   1983
DETERMINATION MiDE BY       ILLINOIS EPA                  CHRIS ROMAINE                        (217 )-782-2113
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION  LIMITS                                    ... * BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT OR PROCESS  MODIFICATION  ... FCT EFF


COATER & OVENS
                                                          VOC      209.6000  T/YR                                              LAER
                                                                            COATINS BREAKDOWN SEE NOTES


NOTES 	
COATING SOLVENT LIMITATION - INSIDE SPRAY 3.63  LB/GAL,  BOTTOM END SPRAY 2.1  LB/GAL, OVERVARNISH 2.1  LB/GAL, BASECOAT 1.8 LB/GA
L
















                                                                                                      INITIAL RtVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEW STATUS:  04/01/19'33    CVC4/1-W

PAGE G- 259                                           ID K"J!!2ER  IL-0011                                     SC'J^CE TfPE CCDE    4.1

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/33/1984



SOURCE TYPE/SIZE — -         SURFACE COATING - CANS/COILS


COMPANY NAME/SITE LOCATION  PREFINISH METALS                                            WALBRIQGE, OH


DETERMINATION IS LAER FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—  05/04/79
PERMIT HO. 03-746                                                                             ESTIMATED DATE OF START-UP—   1931
DETERMINATION MADE BY       OHIO EPA NWD                   CHUCK HULL                          (4191-352-8461
                             (AGENCY)                  (AGENCY CONTACT PERSON)                    (FHCNE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   . . . & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF


Z COIL COATERS 4 OVENS           700000.00  T/H VARIES
                                                          VOC      37.0000 LB/H
                                                                           AFTERBURNERS                                     97.00


NOTES 	
(*> INDICATES DATUM WAS TRUNCATED FOR THIS  TABLE.

PAGE G- 260
                                                                                                     INITIAL REVIEW  POST STARTUP
                                                                                        REVIEW STATUS;  04/01/1^3
ID NUMBER OH-0039
                                                     SOURCE  TYPE  CODE     4.1

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                         05/22/1984



SOURCE TYPE/SIZE—         SURFACE COATING - CANS/COILS


COMPANY NAME/SITE LOCATION  STROH CONTAINER                                                FREMONT, OH
                           	.	•	

DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF  PERMIT ISSUANCE—  08/30/79
PERMIT NO. 03-807                                                                              ESTIMATED  DATE Or  START-UP--   1931
DETERMINATION MADE BY       OHIO EPA NWD                   DON WALTERMEYER                     («._« _ — — _ _

BASE, BOTTOM, AND INTERNAL COAT*   3000.00 CANS/MIN.
                                                           VOC      ^0.0000 T/YR
                                                                            CATALYTIC INCINERATOR                             90.00


NOTES 	
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE 6- 261
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS:  04/01/19S3
                                                      ID NU::BER OH-oo3&
                                                                                                            SOURCE  TYPE CODE

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/198'*
-~z = = = =- = = = = = ~ =-- = - = ---- = --- = - = = = = ----=---- = ~-~~--= = ~ = - = = = = = -- = ~ = ~ = ~---=-~ = ~~~---~ = = ~--- = = ---- = ~~~~ = = ~:~~ = = ~~ = ~ = ~~~ = = = = ~:=~ = ~~~~ = ~~~


SOURCE TYPE/SIZE—-         SURFACE COATING - PAPERS/FABRICS


COMPANY NAME/SITE LOCATION  ALLIED PRINTERS & PUBLISHERS, INC.                               TULSA, OK


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE—  03/13/81
PERMIT NO. T80-74                                                                              ESTIMATED DATE OF START-UP--   I960
DETERMINATION MADE BY       TULSA CITY-COUNTY HEALTH DEPT  JIM VAN SAKDT                       (918)-744-1000
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF
	—	_____.. — ..___. — ..	,.—	—	•	— —	— —	—, — _-.,.-.__ — -.—	________ _	— —	— —	— —	— —	— — —	— ~ ——	


WEB OFFSET PRINTING PRESS           800.00 FT/SEC
                                                           VOC       0.7140 LB/H
                                                                            STRAIGHT FLAME INCIN., W/PREHEATER               90.00
                                                                            HIGH SOLIDS INK (68X)


NOTES 	
1) DECREASE IN VOC CONTENT. EFFICIENCY = IZ.5X. 2) CONVERSION OF PHOTOCHEMICAL REACTANTS TO NON-REACTANT MATERIALS. EFFICIENCY
 = 90X
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 262
ID NUMBER OK-0016
                                                INITIAL REVIEW  POST STARTUP
                                   REVIEW STATUS:  04/01/1033
                                                     SOL'"CE TYPE CODE    <+.2

-------
                                             APPENDIX —  DETAILED SOURCE LISTING
                                                                                                                        05/22/198*
SOURCE TYPE/SIZE---         SURFACE COATING - PAPERS/FABRICS


COMPANY NAME/SITE LOCATION  AVERY INTERNAT                                        PAINESVILLE TWP., OH
                                                                                                                       LAKE COUNTY


DETERMINATION IS LAER FOR A NEW SOURCE.                                                         DATE OF PERMIT ISSUANCE—  06/11/81
PERMIT NO. 0243110957                                                                          ESTIMATED DATE OF START-UP--
DETERMINATION MADE BY       OHIO EPA NED                   DENNIS BUSH                         (216 )-425-9171
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ...» BASIS
TO THIS PERMIT                         CAPACITY           EMITTED            CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ... PCT EFF
—	— —	—	— —	— —	—	— — —	— - —	— —	— —	— _ — _..__	_.. — __________ ...,_ — ..__...„__..	„	___..»___ ____„_______	„_______,.___	_ — ___-...

VINYL AND PAPER COATING LINE         63.90 GAL/H
                                                           VOC       2.6000 LB/6AL COAT. APPLIED                              LAER
                                                                   132.8000 T/YR
                                                                            LOW SOLVENT COATING


NOTES 	
LAER LIMITS AND ANNUAL MAX. EMISSION IMPOSED BY  PERMIT CONDITIONS WHICH REQUIRES REDUCTIONS FROM  SOURCE K007 OF 159.4 TPY TO P
ROVIDE THE OFFSET AMD FURTHER REDUCTIONS FROM 6  (CONT. 27)
OTHER COATINS LINES TO LIMIT VOC EMISSIONS TO 2.05 LB/GAL,  EXCL. WATERBY 4-1-82
(*> INDICATES DATUM HAS TRUNCATED FOR THIS TABLE.

PAGE G- 263
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS;  04/01/1933
                                                      ID  NUMBER  OH-0014
                                                                                                           SOURCE TYPE CODE

-------
                                             APPENDIX  — DETAILED  SOURCE  LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE—-         SURFACE COATING - PAPERS/FABRICS


COMPANY NAME/SITE LOCATION  DIETZ6EN CORP.                                               DES  KOINES,  IL


DETERMINATION IS LAER FOR A NEW SOURCE.                                                        DATE  OF  PERMIT  ISSUANCE—   12/11/80
PERMIT NO. C8006034                                                                           ESTIMATED  DATE  OF  START-UP—    1982
DETERMINATION MADE BY       EPA REGION V                  CHRIS  ROMAINE                       (217 )-732-2113
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (FHCNE )



PROCESSES SU3JECT                     THROUGHPUT         POLLUTANT    EMISSION  LIMITS                                    ... &  BASIS
TO THIS PERMIT                         CAPACITY           EMITTED             CONTROL EQUIPMENT  OR  PROCESS  MODIFICATION   ... PCT EFF


ROLLER COATER LINE
                                                          VOC        0.6000  LB/GAL COATING                                    LAER
                                                                            AFTERBURNER                                       90.00


NOTES	                                                     :
90X EFFICIENCY REQUIRED OF AFTERBURNER SYSTEM (CAPTURE  & DESTRUCTION).
<») INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 264
                                                                                                      INITIAL  REVIEW  POST  STARTUP
                                                                                         REVIEW  STATUS:   C^/01/1°S3     04/04/1934
ID NUMBER IL-0013
                                                     SOURCE TYPE CODE    4.2

-------
                                            APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE—
                            SURFACE COATINS  -  PAPERS/FABRICS
                                                                                             240.00  LB/H
COMPANY NAME/SITE LOCATION  FRYE COPY SYS,  INC
                                                                                            GOSHEN,  IN
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT NO. PC(20)1460
DETERMINATION MADE BY       INDIANA APCO
                             (AGENCY)
                     FRANK PROFIT
                  (AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE--  11/07/00
                                       ESTIMATED DATE OF START-UP--
                                       (317)-633-0664
                                           (PHCHE)
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
& BASIS
PCT EFF
PAPER COATING LINE
                                    240.00  LB/H
                                                          VOC
                                                                    25.0000 T/YR
                                                                           CARBON  ABSORBER
                                                                                                                             95.00
NOTES 	
4000 MRS/YEAR OPERATION
<*) INDICATES DATUM WAS TRUNCATED  FOR  THIS TABLE.

PAGE G- 265
                                                     ID NUMBER IN-0019
                                                                INITIAL REVIEW  POST STARTUP
                                                   REVIEW STATUS:   04/01/1983

                                                                     SOURCE TYPE CODE    4.2

-------
                                             APPENDIX  —  DETAILED  SOURCE LISTING                                        05/22/1984
SOURCE TYPE/SIZE—-         SURFACE COATING - PAPERS/FABRICS





COMPANY NAME/SITE LOCATION  GAZETTE PRESS PRINTING                                      PITTSBURGH ,  CA
             ,          " * *"
PERMIT NO. Zoic?                                                                               .,,,-» -,-,,  tn*n
DETERMINATION MADE BY       BAY AREA AQMD                  MOHAMAD MDAZED                      (415>-771-6000
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)
          SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... & BASIS

TO THIS'PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  . . . PCT JFF






DRYING OVENS                      12950.00 CF/M

                                                           VOC       9.0000 LB/D

                                                                            FUME INCINERATOR                                 95.00








FUME INCINERATOR 13950 CFM KATEC, TVA-8U, FILE A 340-007. SOURCE OPERATES \Z H/0 , 6 D/WEEK, 52 WEEK/YR.
                                                                                                      INITIAL REVIEW  POST STARTUP


 (*)  INDICATES  DATUM  WAS  TRUNCATED  FOR  THIS TABLE.                 _          	-f^:'-.!!*!-!! —?-!'=?--!! = — = = = = = === = = = =



 PAGE=6-"6r=S ==== = === = = = = = = = === = === = = = = = "           iD~NUM3ER~CA-005*SCISCE TYPE CCDE    4.2

-------
                                             APPENDIX  — DETAILED  SOURCE  LISTING
                                                                                                                        05/22/198*



SOURCE TYPE/SIZE—         SURFACE COATING - PAPERS/FABRICS


COMPANY NAME/SITE LOCATION  H.S.  CROCKER CO.  PRINTING                                     SAN BURNO,  CA


DETERMINATION IS BACT FOR A NEW SOURCE.                                                         DATE  OF PERMIT ISSUANCE—  03/21/82
PERMIT NO. 28709                                                                               ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY       BAY AREA AQMD                 MOHAMAD MOAZED                      (415J-771-6000
                             (AGENCY)                  (AGENCY  CONTACT PERSON)                     (PHONE)



FPOCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION LIMITS                                   ... & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ... PCT EFF


FRINTIN3 PRESS, 64 INCH
                                                          VOC      415.0000 LB/D
                                                                            SEE  NOTE


NOTES 	
VOC<2.5 LB/GAL LIMIT VOC CONTENT OF INKS. FILE A  340-008.  SIX COLOR PRESS OPERATES 14  H/D,  5 D/WEEK, 48 WEEK/YR.
(»> INDICATES DATUM WAS TRl'S'CATEO FOR  THIS  TABLE.

PAGE G- 267
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS:  04/19/1934
                                                      ID NUMBER CA-0055
                                                                                                           SCt'RCE TYPE CG3E    4.2

-------
                                             APPENDIX  — DETAILED  SOURCE  LISTING
                                                                                                                        05/22/l?34




SOURCE TYPE/SIZE	         SURFACE COATIHS - PAPERS/FABRICS


COMPANY NAME/SITE LOCATION  INLAtID, DIVISIOH OF  G.M. CORP.                                 VANDALIA,  OH


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE  OF PERMIT ISSUANCE—  09/18/80
PERMIT NO. 0857170135 K001                                                                     ESTIMATED  DATE OF START-UP--   1977
DETERMINATION M4DE BY       REGIONAL APCA                  JAMES GROSS                         <513J-225-4435
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION LIMITS                                   ...  & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT OR PROCESS  MODIFICATION  ...  PCT EFF
	•	

LEMSO GRAVURE VINYL COATER           45.00 GAL/H
                                                           VOC      83.8400 LB/H                                             TECH
                                                                            CARBON ADSORPTION                                73.00


NOTES 	
THE 73X EFFICIENCY REPRESENTS THE FIRST EFFICIENCY DETERMINATION.  SEMI-ANNUAL EVALUATIONS WILL BE PERFORMED.
 (*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

 P,iGE G- 263
                                                                                                      INITIAL RtVIEU  POST STARTUP
                                                                                         REVIEW STATUS:
ID NUMBER OH-0048
                                                     SOURCE TYPE CODE    4.2

-------
                                              APPENDIX — DETAILED SOURCE LISTING


 		                                                                                                               05/22/1954
 	— = —— — — S —= ~rs~mrzrs~ — — — — — — — — — *- — — — — - — — —	— — — _ — — __ — — _..«._	— — —...___ ___  _
                                 	— —	— *• —	— — —	—— _—	— — — — — —_s = r:r:~c — rs~~ srzzs^zsi; si: s = ss~—~s~ = — ~i:s = = = s~ = ^~r






 SOURCE TYPE/SIZE	         SURFACE COATING - PAPERS/FABRICS







 COMPANY NAME/SITE LOCATION  INTERNAT. LABEL MFG. FAC.                                   CLARKSVILLE, TN


                                                                                                                    MONTGOMERY COUNTY

                            "•fc— — "* — — ——— — ——— — — — — — — — — —__ — »-_••.„.„ __• ——„___... —— ta_—« _ ... -._—__ __ — .. — — _ — «n_ _ __ -.— —.__ — —.-. — -.—.. —w. — —........ — — — . ••.• ^—— — v_





 PFPMT™      °R * NEW SOURCE'                                                         OATE OF PER»IT ISSUANCE-  03/26/80
 PERMIT NO.  PSD-TN-060                                                                           ESTIMATED DATE OF START-UP-

 DETERMINATION MADE BY       TENNESSEE APCD                 ANGIE PITCOCK                       (615)-741-3651


                              (AGENCY)                   (AGENCY CONTACT  PERSON)                    (PHONE)




                        — — — :; = —:;;: — ;; — — --__..__ = = = = S = = = = = = a = = = = = = = = = = = = = = = = = = = = = r = = = = = = = = = = S = = = S = = = = = = — - = = -= = = - = = = = = = -= = = = = = = = =




                                       THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... 4 BASIS


 __.__.____                             CAPACITY          EMITTED             CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF

                                        •"~~™~~~*-"'~~'"~"'1-* — —— — — — «•••• — -•—•»—-. — — — — — — **.._ — — .. — _ •.— — ^_ — — — _ — ™ —— ^^_ _ — „_,._•..__ ™,^__ — ».»^™. —^ — — «.«.-. — _ — — «.•




 PAPER  PRINTING                     3454.00 LB/H


                                                            VOC      46.9400 T/YR                                              LAER


 BOTtFPS  NiT  TA.J  x CA                                                      CARBON ADSORP. BEDS + INCIN.                      99. ?0
 D'JILtRi), NAT.  GAS,  3 EA


                                                            S02     152.8800 T/YR                                              EACT





 NOTES  	










































m INDICATES DATUM  WAS TRUNCATED  FOR  THIS TABLE.                                          REVIEW STATUS-""4/01/1983"  ^^ STARTUP




PAGE G- 269                                            ID  NUMBER TN-0004                                      SOURCE TYPE CODE    4.2

-------
                                             APPENDIX  -- DETAILED  SOURCE  LISTING
                                                                                                                        05/22/1934
SOURCE TYPE/SIZE-—         SURFACE COATING - PAPERS/FABRICS


COMPANY NAME/SITE LOCATION  ITEM FIBRE CO.                                               ASHTABULA, OH
                                                                                                                  ASHTAEULA  COUNTY
DETERMINATION IS LAER FOR A NEW SOURCE.                                                        DATE OF  PERMIT  ISSUANCE—   12/23/81
PERMIT NO. 0204010112                                                                         ESTIMATED DATE  OF  START-UP--
DETERMINATION MADE BY       OHIO EPA NED                   DENNIS  BUSH                         <216J-425-9171
                             (AGENCY)                   (AGENCY  CONTACT  PERSON)                     (FHCNE )
PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION  LIMITS                                    ...  8 BASIS
TO THIS PERMIT                         CAPACITY           EMITTED             CONTROL EQUIPMENT OR PROCESS MODIFICATION   ...  PCT  EFF


RESIN COATING LINE
                                                           VOC        2.9000  LB/GAL COAT.  APPLIED                             LAER
                                                                   516.0000  T/YR
                                                                            LOW SOLVENT COATING


NOTES 	
COMPANY TO REPORT QUARTERLY OR MONTHLY COATING USE,  TOTAL VOC EMISSIONS,  AND LB/GAL VOC EMISSIONS RATE.

OFFSETS NOT REQUIRED RURAL APEA.
                                                                                                      INITIAL  REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEW  STATUS:   04/01/19S3
PAGE G- 270                                           ID  NL'MoER  OH-0015                                    SOURCE  TYPE  CCOE

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE—-         SURFACE COATING  - PAPERS/FABRICS                                 450.00 LB/H


COMPANY NAME/SITE LOCATION  MURRAY RUBBER, (MEAD COMPANY)                                  HOUSTON, TX  77040
                                                                                                                     HARRIS COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF  PERMIT  ISSUANCE—  07/01/82
PERMIT NO. 9040                                                                               ESTIMATED  DATE  OF  START-UP--   1982
DETERMINATION HADE BY       TEXAS ACS                     ART KELLOGG                         (5X3J-451-5711
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHCUE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                    ...  & BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS  MODIFICATION  ...  PCT EFF


FABRIC COATER                       450.00 LB/H
                                                          VOC      27.0000 LB/H
                                                                           THERMAL OXIDIZER                                  90.00


NOTES 	
THIS SYSTEM REDUCES EMISSIONS TO 0.83 LB/GAL APPLIED W/GREATER THAN 90X EFFICIENCY (MAXIMUM). TACB REGULATIONS &  EPA  GUIDELINE
S ALLOW A MAX. OF 2.9 LB/GAL APPLIED. THE OXIDIZER REQUIRES NO FUEL FOR OFER.  OTHER THAN THE DRYER EMIS.
                                                                                     I
<*) INDICATES DATUM WAS TRUNCATED  FOR  THIS TABLE.

PAGE G- 271
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS:  04/01/1933
                                                     ID NUMBER TX-0086
                                                                                                          SOURCE TYPE  C03E     4.2

-------
                                             APPENDIX  — DETAILED SOURCE  LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE---         SURFACE COATING - PAPERS/FABRICS


COMPANY NAME/SITE LOCATION  NDM CORP.                                                      MORAINE, OH


DETERMINATION IS LAER FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—  07/23/82
PERMIT NO. 0857101457 K001                                                                    ESTIMATED DATE OF START-UP—   1982
DETERMINATION MADE BY       RAPCA - DAYTON,OH             THURMAN SMITH                       (513>-225-4435
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                    ... t BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   . ... PCT EFF


PAPER COATINS                        30.00  FT/MIN
                                                          VOC      19.0000 LB/H
                                                                   11.4000 T/YR
                                                                           THERMAL INCINERATOR                              99.70


NOTES 	
THERMAL INCINERATOR WAS TESTED AT 99.77. OVERALL EFFICIENCY. COATING MUST  MEET  2.9  LB VOC/GAL COATING OR CONTROL EQUIPMENT MUST
 PROVIDE AN EMISSION REDUCTION OF 50.5X. PERMIT RESTRICTS OVERALL EFFICIENCY TO NO LESS THAN 85.5X.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 272
                                                                                                     INITIAL REVIEW  POST STARTUP
                                                                                        REVIEW STATUS:  04/01/1933    02/13/19C4
ID NUMBER OH-OC43
                                                     SOUPCE TYPE CC3E
                                                                         4.2

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE—         SURFACE  COATING - PAPERS/FABRICS


COMPANY NAME/SITE LOCATION  STECHER-TRAUNG-SCHMIDT                                          NEWARK, CA


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE--   10/08/82
PERMIT NO. 28246                                                                              ESTIMATED DATE OF START-UP--    1983
DETERMINATION MADE BY       BAY AREA AQMD                  ELLEN LINDER                        (4151-771-6000
                             (AGENCY)                  (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                    . .. t  BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF


OVEN, VARNISHER DRYING            4000.00 SHEETS/H
                                                          VOC      67.0000 LB/D                                              BACT
                                                                           HIRT FUME INCINERATOR                             90.00


NOTES 	
OVERALL EFFICIENCY 90X,  97X IN-OUT OF INCINERATOR.
<*) INDICATES DATUM WAS TRUNCATED FOR  THIS TABLE.

PAGE G- 273
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS:  04/19/1934
                                                     ID NUMBER CA-0050
                                                                                                           SOURCE  TYPE  CODE     4.2

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE—         SURFACE COATING - AUTO./LIGHT DUTY TRUCKS
                           __—.^_—.____«.___•.____«._•— ^____—, — —._ — — —.• — — — — — — — — — — — — — — — — —^ —— — — — — -* — — — — — — — — — — •-— — — — — — — — «• — — — — ^-^ —— — — — —— — — — — ———•"-• —

COMPANY NAME/SITE LOCATION  CHEVROLET - FLINT MANUFACTURING                                  FLINT, MI
                            3CO NORTH CHEVROLET AVE


DETERMINATION IS LAER FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—  03/07/84
PERMIT NO. 95-84                                                                               ESTIMATED DATE OF START-UP—   1934
DETERMINATION MADE BY       MICHIGAN DNR                   GREGORY EDWARDS                     <517)-3£2-1333
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... t BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  .... PCT EFF
__,-.______..___..____.. _ _ ——. __«.___v,H_»«__W» — «.^— — — — —._ _ _.-.—_ —_.——, — — ————— — ______ _ ..»___ — — _ _ .»__ — ___ — — .. — — — _«__ — — _ _ —_..-—..._ _ _______ __ •.——_ — — —

SPRAY BOOTH, SOUND DEADENER         300.00 PARTS/H
                                                           VOC      78.5000 LB/H SEE NOTE                                    LAER
                                                                   108.0000 T/YR SEE NOTE
                                                                            AIRLESS GUNS S TIMED SPRAYING
SPRAY BOOTH, REINFORCEMENT          300.00 PARTS/H
                                                           VOC      78.5000 LB/H SEE NOTE                                    LAER
                                                                   108.0000 T/YR SEE NOTE
                                                                            AIRLESS GUNS 4 TIMED SPRAYING


NOTES 	
NOTE - EMISSION LIMITS ON VOC ARE FOR BOTH BOOTHS COMBINED.











                                                                                                      INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:

PAGE G- 274                                           ID NUMBER MI-0035                                    SOURCE T»FE CC3E    4.3

-------
                                             APPENDIX —  DETAILED  SOURCE LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE —
                            SURFACE COATING - AUTO./LIGHT DUTY TRUCKS
                                                                                              75.00 CARS/H
COMPANY NAME/SITE LOCATION  CHRYSLER CORP.
                            JEFFERSON AV. ASSEMBLY PLANT
                                                          DETROIT,  MI 48226
                                                                                                                      WAYNE COUNTY
DETERMINATION IS LAER FOR A MODIFIED SOURCE.
PERMIT NO. C-5366 THRU C-5369
DETERMINATION MADE BY       WAYNE COUNTY APCD
                             (AGENCY)
PROCESSES SUBJECT
TO THIS PERMIT
     THROUGHPUT
      CAPACITY
                          AL SCHEANS
                       (AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE—  06/05/80
                                       ESTIMATED DATE OF START-UP—    19SO
                                       (313)-224-4693
                                           (PHONE )
POLLUTANT    EMISSION LIMITS                                    ... t BASIS
 EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... FCT EFF
TACK-OFF BOOTH


COLOR SPRAY BOOTH


COLOR FLASH-OFF BOOTH

DOUBLE-WIDTH OVEN
500000.00 SCFM


 10000.00 SCFM

  6663.00 SCFM
   VOC


   VOC


   VOC

   VOC
        EXHAUST THRU SPRAY BOOTH


        SEE NOTE

25.2000 LB/GAL APPL. SOL

12.9000 LB/GAL APPL. SOL
        OVEN EXHAUST IHCIN.
                                                                                            LAER
LAER
                                                                                                                             90.00
NOTES 	
STAGED LAER CONCEPT PROVIDING FCR PHASE-IN OF  NEW  TECHNOLOGY  AS  IT  IS  DEVELOPED  -  PHASE  1,  START UP USING LOW VOLTAGE ELECTROS
TATIC PAINT SPRAYING AND OVEN EXAUST INCINERATION;  PHASE  2, INTRCDUCTICM CF  HIGH VOLTAGE
ELECTROSTATIC PAINT SPRAYING; PHASE 3,  INTRODUCTION OF HIGH SOLIDS  TOPCOAT ENAMELS BY  8/31/83.
(*1 irDICATES DATUM WAS TRUNCATED F09  THIS  TADLE.

PAGE G- 275
                                                                     INITIAL REVIEW  POST STARTUP
                                                        REVIEW  STATUS'-   04/01/1SS3
                                                     ID N'JtSER MI-COC8
                                                                                                           SO'JRCE TYPE CODE

-------
                                             APPENDIX —  DETAILED  SOURCE LISTING
                                                                                                                        05/22/1934



SOURCE TYPE/SIZE—-         SURFACE COATING - AUTO./LIGHT DUTY  TRUCKS


COMPANY NAME/SITE LOCATION  FHC CORP.  - SAN JOSE ORDINANCE                                SAN JOSE,  CA


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE  OF PERMIT ISSUANCE--  06/22/82
PERMIT NO.  28310                                                                               ESTIMATED  DATE OF START-UP--
DETERMINATION MADE BY       BAY AREA AQMD                 BRIAN BATEMAN                       (415)-771-6000
                             (AGENCY)                   (AGENCY CONTACT  PERSON)                     
-------
                                             APPENDIX —  DETAILED SOURCE LISTING
                                                                                                                         05/22/1934
SOURCE TYPE/SIZE—
                            SURFACE COATING -  AUTO./LIGHT DUTY TRUCKS
COMPANY NAME/SITE LOCATION  F0 INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEW STATUS:  04/01;?933     03/13/19S4

PAGE G- 277                                           ID NUMBER MI-0017                                    SOURCE TYPE  CODE    4.3

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1934
SOURCE TYPE/SIZE —
                            SURFACE COATING - AUTO./LIGHT DUTY TRUCKS
                                                                                              60.00 TRUCKS/H
COMPANY NAME/SITE LOCATION  G(1 WORLD WIDE TRUCK DIV
                            2601 WEST STROOP ROAD
                                                     MORAINE, OH 45439
                                                                                                                 MONTGOMERY COUNTY
DETERMINATION IS LAER FOR A NEW SOURCE.
PERMIT NO. 08-215
DETERMINATION MADE BY       RAPCA - DAYTON,OH
                             (AGENCY)
                     GORBY LEE
                  (AGENCY  CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE—  05/13/80
                                       ESTIMATED DATE OF START-UP—   19S1
                                       <513)-225-4435
                                           (PHCNE)
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT    EMISSION LIMITS                                   ... 8 BASIS
 EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
ELPO PRIME
PRIMER SURFACER
TOP COAT
ANTI-CORROSION
PLASTISOL/ANTI-CHIP
                                     63.50 UNITS/H
                                     63.50 UNITS/H
                                     63.50 UNITS/H
                                     63.50 UNITS/H
                                     63.50  UNITS/H
                     VOC        1.2000  LB/GAL COATING MINUS H20
                                      CATHODIC EDP

                     VOC        2.8800  LB/GAL COATING MINUS H20
                              15.8400  LB/G4.L VOC  SOLIDS  AFPL
                                      WITH  bZ7. TRANSFER  EFFICIENCY

                     VOC        3.6000  LB/GAL COATING MINUS H20
                              15.0500  LB/GAL VOC  SOLIDS  AFPL
                                      WITH  59X TRANSFER  EFFICIENCY

                     VOC        4.3000  LB/GAL COATING MINUS H£0
                                      WITH  90X TRANSFER  EFFICIENCY

                     VOC        3.5000  LB/GAL COATING MINUS H£0
                                      WITH  50X TRANSFER  EFFICIENCY
                                                                                                                             LAER
                                                                                                                             LAER
                                                                                                                             LAER
                                                                                                                             LAER
                                                                                                                             LAER
PAGE G- 278

-------
(CONTINUED) GM WORLD HIDE TRUCK DIV
PROCESSES SUBJECT
TO THIS PERMIT
CHASSIS BLACK

WHEEL PAINT

MAST JACKET

FINAL REPAIR

THROUGHPUT
CAPACITY
63.50 JOB/H

63.50 JOB/H

63.50 JOB/H

63.50 JOB/H

POLLUTANT
EMITTED

VOC

VOC

VOC

VOC
EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

3.5000 LB/GAL VOC MINUS HZO

3.7000 LB/GAL VOC MINUS HZO

6.3000 LB/GAL VOC MINUS H20

4.8000 LB/GAL VOC MINUS H20
...& BASIS
... PCT EFF








NOTES 	
MISCELLANEOUS FUGITIVE VOC EMISSIONS  ARE ESTIMATED TO TOTAL 488 TPY FROM THIS FACILITY.

TOTAL VOC EMISSIONS NOT TO EXCEED  2050 TPY
                                                                                                     INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED  FOR THIS TABLE.                                        REVIEW STATUS:  04/01/1983     02/13/1934

PAGE G- 279                                          ID NUMBER OH-0009                                    SOURCE TYPE  CC3E     4.3

-------
                                             APPENDIX -- DETAILED SOURCE  LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE---         SURFACE COATING  -  AUTO./LIGHT DUTY TRUCKS
COMPANY NAME/SITE LOCATION  VOLKSWAGEN OF  AM                                      STERLING HEIGHTS, MI 48077
                            16 MILE ROAD t VAN DYKE AVENUE                                                          OAKLAND COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                       DATE OF PERMIT  ISSUANCE—   06/01/80
PERMIT NO. 250-80 TO 273-60, 3*                                                               ESTIMATED DATE  OF START-UP—
DETERMINATION MADE BY       MICHIGAN DNR                   JON TROUT                           (517)-322-1333
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (FHCNE )
PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                    ...  &  BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ...  PCT  EFF
_— __„ __„ ___-.-__— V •. _ _•> W _ _ _• •— — —. — !_ — — — — — — — — _ — — — -. ____. — __w__ ~ — __» « ___ _ ___»___-. «. — »_•__„_•_•.__——• — — — — — — — ———— — •— — —— — — ——— — •— — — — •- — — — — — — W— — — — —.


PAINTING OPERATIONS
                                                          VOC              SEE  NOTE
                                                                           SEE  NOTES



NOTES 	
CHECK WITH STATE FOR DETAILS. EMISSION LIMITS TOO  EXTENSIVE TO MENTION HERE.
                                                                                                      INITIAL REVIEW  POST STARTUP
(#) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEU STATUS:   04/01/1933    03/13/19&4
PAGE G- 280                                           ID  NUMBER  MI-0007                                    SC'JRCE TYPE  CCDE

-------
                                            APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                        05/22/198*
SOURCE TYPE/SIZE—         SURFACE COATING  - METAL FURNITURE


COMPANY NAME/SITE LOCATION  KINCAID FURNITURE CO., INC.                                      LENIOR,  NC


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE  OF PERMIT ISSUANCE—  10/17/83
PERMIT NO. 5276                                                                                ESTIMATED DATE OF START-UP—   198*
DETERMINATION MADE BY       NORTH CAROLINA DEM             MIKE SEWELL                          (919)-733-7015
                             (AGENCY)                   (AGENCY CONTACT  PERSON)                     (PHCNE)



PROCESSES SUBJECT                     THROUGHPUT         POLLUTANT     EMISSION LIMITS                                   ... * BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ... PCT EFF
— — —	—	—	— —	— —	— — — — — __-...__	_	__	_„	.,___,.	_	______,.__	___________	_	____	_______	.,____ — ,.__..	_	— _ —

FINISHING OPERATION
                                                          voc
                                                                            NONPHOTOCHEMICALLY REACTIVE FINISHING MATL.
BOILER, WOODWASTE, 2                 11.60 MMBTU
                                                          VOC
                                                                            GOOD OPERATING PRACTICES


NOTES 	
PSD ONLY FOR VOC EMISSIONS.














                                                                                                      INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEW STATUS:  04/19/19S4

PAGE G- 281                                          ID NUI'.BER NC-0031                                     SOURCE TYPE CODE    4.4

-------
                                             APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE — -         SURFACE COATING - METAL FURNITURE


COMPANY NAME/SITE LOCATION  STEELCASE,  INC.                                          GRAND RAPIDS, MI 49501
                            1120 36TH STREET                                                                          KENT COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                       DATE OF PERMIT ISSUANCE—  06/01/80
PERMIT HO. 51-80                                                                              ESTIMATED DATE OF START-UP—   1981
DETERMINATION MADE BY       MICHIGAN DNR                  JOHN CAUDELL                        (517J-322-1333
                             (AGENCY)                  (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... * BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
BOILER, COAL FIRED, 2 EA
40000.00 LB/H
COAL t ASH HANDLING SYS.
                         PM         0.0500  LB/MMBTU
                                          CYCLONE t BAGHOUSE
                         S02        1.6000  LB/MM3TU
                                          LOW S COAL, MAX IX
                         NOX        0.6000  LB/MMSTU
                                          CONTROL EXCESS * OVERFIRE AIR

                         PM         0.0300  GR/DSCF
                                          FABRIC FILTER
                                          DUST SUPFRESENT
                                                                                                                            99.00
NOTES
(*) INDICATES DATUM WAS TRUNCATED  FOR  THIS TABLE.

PAGE G- 282
                                                                   INITIAL REVIEW  POST STARTUP
                                                      REVIEW STATUS:  04/01/1933    03/13/1954
                                                     ID NUMBER MI-0018
                                                                                                          SOURCE TYPE CC3E
                                                                                                                              4.4

-------
                                            APPENDIX -- DETAILED SOURCE  LISTING
                                                                                                                        05/22/1934
SOURCE TYPE/SIZE—-
                            SURFACE COVTING  - MAGNET WIRE
COMPANY NAME/SITE LOCATION  PHELPS DODGE,  MAGNET WIRE CORP.
                            P.O.  BOX 768
                                                HOPKINSVILLE,  KY
                                                                                                                  CHRISTIAN COUNTY
DETERMINATION IS BACT FOR A MODIFIED SOURCE.
PERMIT HO. C-75-16
DETERMINATION MADE BY       KENTUCKY DAPC
                             (AGENCY)
                     BILL DILLS
                  (AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE—  03/25/75
                                       ESTIMVTED DATE OF START-UP—   1976
                                       (502J-5&4-33S2
                                           (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT    EMISSION LIMITS
 EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION
& BASIS
PCT EFF
OVENS,
OVENS, FINE WIRE, 10
                                   1501.00  T/YR COATING
                                    165.00  T/YR COATING
OVENS, 1 HEAVY & 1 MEDIAN WIRE      514.00  T/YR COATING
OVENS, 6 HEAVY ft 1 FINE WIRE       2158.00  T/YR COATING
OVEN, 1 FINE WIRE
                                     16.00  T/YR COATING
                     VOC      40.8000 LB/H
                             675.4900 T/YR
                                      INCINERATOR

                     VOC       4.5500 LB/H
                              19.1100 T/YR
                                      INCINERATOR

                     VOC      13.9600 LB/H
                              58.6000 T/YR
                                      INCINERATOR

                     VOC      31.3000 LB/H
                              85.9000 T/YR
                                      CATALYTIC (1350 F), THERMAL INCINERATOR

                     VOC       0.4550 LB/H
                               1.9100 T/YR
                                                                     90.00



                                                                     90.00



                                                                     90.00

                                                                     BACT

                                                                     95.CO
NOTES
(*) INDICATES DATUM UAS TRUNCATED FOR  THIS  TABLE.

PAGE G- 283                                          ID NUMBER KY-0035
                                                                INITIAL REVIEW  POST STARTUP
                                                   REVIEW STATUS:  04/01/1
-------
ALSO COVERS PERMIT NUMBERS C-75-23, C-77-75, C-78-60, C-79-013.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE 6- 2S4
                                                                                                      INITIAL REVIEW   POST  STARTUP
                                                                                           ,'ic,; STATUS:  0^/01/1953     02/13/1934
ID NUMBER KY-0035
                                                     SOl'~CE TYPE CODE    4.5

-------
                                            APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                        05/22/1964



SOURCE TYPE/SIZE—         SURFACE COATING  -  LARGE APPLIANCES


COMPANY NAME/SITE LOCATION  SANYO E*E CORP.                                              SAN DIEGO, CA 92123
                            400 RUFFIN RD.


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT  ISSUANCE—  08/21/81
PERMIT NO. 07037                                                                              ESTIMATED DATE  OF  START-UP—    1979
DETERMINATION HADE BY       SAN OIEGO APCO                 LORENZO ALEJANDRIA                  (619)-565-3914
                             (AGENCY)                  (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                    ... t  BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... FCT EFF


COATING LINE                        107.50 GAL/D
                                                          VOC     275.0000 G/LITER OF COATING                                BACT
                                                                           HIGH SOL. COAT. TO LOW SOL. COAT..


NOTES 	
AVERAGE SOLVENT CONTENT OF COATINGS USED BEFORE MODIFICATION WAS 365.9 G/LITER, * AFTER MODIFICATION, THE SOLVENT CONTENT  OF  N
EW COATINGS IS 280 G/LITER (WITH 10X DEVIATION FOR UNSTAHDARDIZED TEST METHOD  USED t AGREED BY APCD).
COATINS LINE INCLUDES ONE AUTOMATIC PAINT SFSAY BOOTH USING ELECTROSTATIC SPRAY DEVICES, TWO TOUCHUP SPRAY BOOTHS, ONE  BAKING
OVEN.
<*) INDICATES DATUM WAS TRUNCATED  FOR  THIS TABLE.

PAGE G- 285
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS:  04/01/1983
                                                     ID NUMBER CA-0043
                                                                                                          SOURCE TYPE  CODE
                                                                                                                              4.6

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                         05/23/1984
SOURCE TYPE/SIZE	         SURFACE COATING - MISC. METAL PARTS/PRODUCTS


COMPANY NAME/SITE LOCATION  ALENCO DIVISION OF REDMAN BUILDING PROD*                               »  TX
                                                                                                                      BRAZOS COUNTY
DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF  PERMIT  ISSUANCE—  04/17/81
PERMIT NO. C-6696                                                                              ESTIMATED  DATE  OF  START-UP--   1981
DETERMINATION MADE BY       TEXAS ACB                      ART KELLOGG                         (5121-451-5711
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)
PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    . . .  i BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS  MODIFICATION  ...  PCT EFF
».«	_-. —	__ — — _-.__— — — — —	____-. — ____ — .__-._.--. — ._-.-.	__.. — _	„ — -. — — — — __ — — — -. — -.-.-._ — — -. — _	___...._..__._..,.-...___...,._ — — ____-. — — —	_____-.____ — ..—

PAINTING EXTRUSIONS                 384.00 LB/H PAINT *
                                                           VOC      65.1000 LB/H
                                                                            DIRECT FLAME INCINERATION                         6&.00
                                                                            USE OF HIGH SOLIDS  PAINT


NOTES	—
EFFICIENCY OF THE BAKE OVEN DIRECT FUME INCINERATION IS ESTIMATED TO BE A MINIMUM OF 68'/., PER  FIG. Ill ON  PG. 181  OF AP-40, B
UT IS THOUGHT TO BE GREATER. HOWEVER, NO SAMPLING WAS REQUIRED FOR THIS LOW EMISSION RATE.
                                                                                                      INITIAL REVIEW   POST STARTUP
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:   05/04*934
PAGE G- 266                                           ID NUMBER TX-0129                                    SOURCE  TYPE  COOE    4.7

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/198*



SOURCE TYPE/SIZE—         SURFACE COATING  - MISC. METAL PARTS/PRODUCTS


COMPANY NAME/SITE LOCATION  AMERICAN METAL DECORATING CO.                                  FREMONT, CA


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF  PERMIT  ISSUANCE—  03/07/80
PERMIT NO. 27361                                                                              ESTIMATED DATE  OF  START-UP—    I960
DETERMINATION MADE BY       BAY AREA AQMD                  JOHN PHILLIPS                       (415)-771-6000
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION  LIMITS                                    ... & BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT  OR  PROCESS MODIFICATION  ... PCT EFF
— —	— — —	— — - — — — — — —	— — — — — « — — — —	—	»„___. —	_ —	— —	————„—	— — — — — — — — _«.	-._ — — — — — — _ — — — _ — — _ — — —	— — — — —	—	— — _	_ — — — — — — ,._	_ —

COATING LINE                      91300.00 GAL/YR
                                                          VOC      250.0000 LB/D
                                                                           FUME INCINERATOR                                  87.00


NOTES 	
FILE A 340-006
<*) INDICATES DATUM WAS TRUNCATED FOR  THIS TABLE.

PAGE G- 287
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS:  04/19/1934
                                                     ID NUM3ER CA-0053
                                                                                                           SOURCE  TYPE  CODE    4.7

-------
tf
CO

(H

C\J
CJ
N
LO
O




































ID
Z
HI

in
HI
_i

UJ
CJ
a.
**^
O
(0

a
UJ
M
t-
LJJ
O

1
1

X
M
C3
y
UJ
a.
a.
^









































i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
t
i
t
i
t
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
t
i
i
i
j
i
i
i
i
i
i
i
1 10
1 H
1 U
1 O
1 D
1 O
1 Ct
i a.
1 X
M in
II h-
ii o:
u <
n a.
n
n —i
n <
II H-
II UJ
II £
II
II •
II U
ii in
II HI
II TC.
u
n i
n
II CD
II Z
II HI
II \—
II <
II O
II U
II
II UJ
ii U
II <
II U-
II tt
n ID
n in
n
n
n
n
n
u
ii
u
n
n i
n i
n i
II UJ
II M
M IH

II X
II UJ
II D.
II V
II t-
II
II UJ
II U
II tt
II ~%
II O
ii in
y.
L«
z

o
u

Ul
a
D

fj
X
0
i-H 1
1
D.
i :D
i i
UJ H-
o a
z <
3 In
in
in li-
nt p

1— UJ r4
HI H r-H
£ •< r-
ct o in <—
UJ ' 1 UJ
D. 0 rH 2
ui ui o
u. i— -
Z CJ
«< 2
a: ui
CD
1^
«_,

















•
UJ
O QJ —
o; o v
0 < CJ
o z
in in uj
-
U CO

CO UJ
o
in r~ *<
M O £

Z M Z
O X O
HI HI
H. • H-

Z Z Z
HI M
£ H. T.

UJ £ 01
H a H-
UJ UJ Ol
a a. o
n
u
i
n
u
u
u
n
n
n
n
u
u
n
u
u
n
i
n
n
u
u
n
u
n
n
i
n
n
u
n
n
u
n
n
n
n
n
u
u
u
n
n
i
u
it
u
u
ii
n
n
n
u
n
n
n
u
n
n
n
ii
n
n
n
n
n
n
n
u
n
u
u
i
n
n
n
n
u
n
i
u
t
t
i
i
i
i
n
u
n
n
n
n
n
n
n
n
i
i
i
u
n
u
n
n
n
n
n
u
n
n
n
u
n
n
n
n
n
u
n
u
u
n
n
n
n
n
n
n
n
in u.
M U-
in uj

CO t-
CJ
« a.

i ,
• >
• •



o
M
1-

U
HI
U.
HI
O
O
£

in
in
UJ
CJ
0
m
a.

K
O
h-
Z
UJ
1

3
cr
UJ
M '
t- -i
HI O
£ a.
H t-
— 1 Z
o
z o

HI
in
in
HI
£
UJ




t-
Z a
< UJ
}— H>
O f—
-I HI
-I £
O Ul
a.








K

f\ i—
X HI
CD U
O <
O 0-
a: <
X CJ


















H-
o
Ul
"1 H-

5 3~
in a
UJ
in a.
UJ
in en
in HI
UJ X
o H.
o
a: o
O. H-
o
o

o
o













tv
UJ
1-
_j in
HI in
U. UJ
_j
>- a.
K HI

x
tn -
S" 0
UJ
ID I-
<{
h- Ul
Z X
HI

O. K
Z
O M
HI <
H. Q.

N- UJ
in in
o <
CC <£l
H. S
or o ui
>- UJ H-
X -J <
t- UJ 3

0
o
-a-

•
f»s






8









































CJ

•.
in
x
H-
o
o
CO

V

o:
Q.
in
        n
        II  UJ
        II  O
3
Ul  M
HI  CO
>  O-
UJ  i-l
o:  x
    •H
-J  O
<  X
HI  J-
I-  O
HI
I  UJ
I  U
I  K
I  ZI3
I  O
i  in
    in  n
    D  u
    I-  n
    <  n
    t-  n
    in  M

    3  !'
    UJ  II
    M  II
    >  II
    UJ  U
    a  n
        n
        n
        n
        n
        II  X
        n  i-
        M
        n  tx
        II  UJ
        II  (O
           *"~
    CO

    H-

    in
    ct
    o
    o
    s
    a:
     h-  II  CO
     <  II  CO
     U  II  Cxi
     l-l  II
         §11   I
         II  CD
     HI  II
         II  UJ
     —  II  CD
     *   II  <
     —  ii  a.

-------
                                             APPENDIX — DETAILED SOURCE LISTING
 		___                                                                                                       05/23/198*



 SOURCE TYPE/SIZE—         SURFACE COATING - MISC. METAL PARTS/PRODUCTS                       9.00 GAL/H


 COMPANY NAME/SITE LOCATION  SQUARE D CO.                                                    OXFORD, OH
                            5735 COLLEGE CORNER RD                                                                   BUTLER COUNTY
                           -"•"•——— — — — — — — — •—..— — — — — _ _ _ ., ___ __ «,_ — •__.. — — -_.— —. — „ __ __ —•,__•.•..„___•_ — _ ..».»_ _..__ «_ ____•._ — ___.„„_»„,„.__..___. •—„__.»___.,_

 DETERMINATION IS                                                                               DATE OF PERMIT ISSUANCE—  01/25/8*
 PERMIT NO. 18-18*                                                                              ESTIMATED DATE OF START-UP—   193*
 DETERMINATION MADE BY       SOUTHWEST OHIO APCA            THOMAS TUCKER                       t513)-251-8777
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



 PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... « BASIS
 TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... FCT EFF
 	~	~	—	_ — ..____	—.„__,_	__ —	«,__ — __	_,.____.____ _ — __	__.. .._	___.._	— _	,»_	„„	_,	_ — ___..____.__»._...___

 PAINT TANK, EOP                    6000.00 SQF METAL/H
                                                           VOC       2.*000 LB/GAL COATING MINUS H20
                                                                     1.0000 LB/GAU
                                                                            WATERBASE COATINGS, ELECTRCDEFCSITION
 SPRAY BOOTH, TOUCH-UP PAINT
                                                           VOC       2.*000 LB/GAL COATING MINUS H20
                                                                     1.1*00 LB/GAL
                                                                            WATERBASE COATINGS


NOTES 	
BACT DETERMINED BY TECHNOLOGY,  ECONOMICS, S SOURCE SIZE.











                                                                                                      INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED  FOR THIS TABLE.                                         REVIEW STATUS:

PAGE G- 289                                           ID NUMBER OH-0060                                    SOURCE TYPE CODE    *.7

-------
                                             APPENDIX  — DETAILED SOURCE  LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE —
                            SURFACE COATING - MISC.  METAL  PARTS/PRODUCTS
COMPANY NAME/SITE LOCATION  TIFTON ALUMINUM CO.
                                                                                            DELHI,  LA
                                                                                                                   RICHLAND  PARISH
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT NO. PSD-LA-514
DETERMINATION MADE BY       LAQD/EPA REGION VI
                             (AGENCY)
                     BHARAT  CONTRACTOR
                  (AGENCY  CONTACT PERSON)
DATE OF PERMIT ISSUANCE—  01/10/8*
ESTIMATED DATE OF START-UP--   19S4
(504)-342-8
-------
                                             APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                          05/22/1984
         — — — — — — — — — — — — — — — — — — ——————_—__________.._ _____.______._..,»_____,.•______„.„„______________.,_______ ___ __. —;!__ — :;;_ — _ —___S———™~—— ;r~x —sm~~



SOURCE TYPE/SIZE—         SURFACE COATING - FLATWOOD PANELING                             63300.00 SQFT/H
                           — — — — — —	— -. — — — — — _ — —	— —. —_	_ _ „	«.• — __•__	— __	— -,__-...___.-..__.._____	__-._____..	— — ___ — ..__—.,.________,___

COMPANY NAME/SITE LOCATION  ABITIBI-PRICE CORP.                                              TOLEDO, OH 43607
                            2900 HILL AVE
                           " — —•" — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — » — — — — — — — — — — — — — — — — — — — •- — — —.-... — .— .— ,... — — — .••.•_•.».— __....__•.»,.„_—..•.«._._ —

DETERHINATION IS LAER FOR A NEW SOURCE.                                                         DATE OF PERMIT ISSUANCE—  07/07/83
PERMIT HO. 04-204                                                                               ESTIMATED DATE OF START-UP—   1980
DETERHINATION MADE BY       TOLEDO ENVIRONMENTAL SERVICE   DALE KRYGIELSKI                     1419J-693-0350
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)




PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF
FLATWOOD PANELING
                                  63300.00 SQF/H
                                                           VOC        2.4000 LB/MSQFT CLASS II HB
                                                                      5.3300 LB/MSQFT CLASS I TB
                                                                             INCINERATION OF SOME VOC EMISSIONS
                                                                             H£0 BASED COATINGS,LOW VOC HISH  SOLIDS COATINGS
                                     59.00
NOTES 	
FACILITY COATS EITHER HARDBOARD OR TILEBOARD BUT NOT BOTH AT THE  SAME  TIME.  ORIGINAL PTI 04-108 ISSUED 01/78. REVISED PTI ISSU
EO 07/83. INCINERATION AND TOTAL SYSTEM EFFICIENCIES ARE LOWER  ESTIMATES SINCE UNDETERMINED AHr.OUNTS OF
FLASHOFF EMISSIONS ARE USED TO COOL THE INCINERATOR EXHAUST. CLASS  II  HARDSOARD HAS 62.BY. CAPTURE EFFICIENCY AND  94.3+X INCINE
RATION EFFICIENCY. CLASS I TILEBOAKD HAS 57.2* CAPTURE EFFICIENCY AND  95.7+X INCINERATION EFFICENCY
(*> INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 291
             INITIAL  REVIEW  POST STARTUP
REVIEW STATUS:  C4/13/1964
                                                      ID NUMBER OH-0049A
                                                                                                            S3l'RCE  TYPE CODE
                                                                                                                                 4.8

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/Z2/1984



SOURCE TYPE/SIZE—         SOLVENT DECREASING
                           —	— — —	—	— —- ——	— —	— — — — — — — — — — — — — — — — — — — — — — — — _ — — — — _... — — — _ — .. — — _ — _ — _ — — — — — — — _ — ..	— — — — — — — — — —	—— — — — — — — — —

COMPANY NAME/SITE LOCATION  ALLOYTEK                                                    GRANDVILLE, MI
                           — — — — — — — — — — — — — — — —	— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —.— — — — — -. — — — — — — — — — _ — _ — — _ — — — — — — — — — — __ — —____ — — _

DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—  08/05/83
PERMIT NO. 258-83A                                                                             ESTIMATED DATE OF START-UP—   1933
DETERMINATION HADE BY       MICHIGAN DNR                   DAVID FERRIER                       <517)-322-1333
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHOSE )



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... 4 BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF


VAPOR DE6REASER
                                                           VOC       8.0000 LB/H
                                                                            REFRIG.  FREEBOARD W/COVER DURING OWN TIME        95.00


NOTES 	
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- Z1Z
                                                      ID NUMBER MI-0033
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS:  0<4/19/193<+

                  SOURCE TYPE CODE    4.9

-------
                                             APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                         05/22/1984
 — —™ — —— — — — » — — — ~— — s^ —~~~~rr~~~ — ~~~~~~~— — — — — —~ — — — ^ — — — — ~ —— — — — — — — — — — — — — — — — — — — — — — — — — ~ — » — — — — w —— — — — — — ——— — — — ™__..__....._.__...».___.. —— — •,._ _,_  _ _
                     _ _ _ •.__ _ — _ — ______.__ ____„.,____ _ — __________ — ———.———_ _ — — __., _ __ ..__ — _., — » — _ — ________ —_ — ___ — __.— — — — __ _ ________ ~~_;T™~_ ^~ —


 SOURCE TYPE/SIZE-—         SOLVENT DECREASING


 COMPANY NAME/SITE LOCATION  BRIGGS « STRATTON CORP.                                MENOMONEE FALLS, WI
                           	•	.	—	.	•	.	_—_	.	

 DETERHINATION IS LAER FOR A NEW SOURCE.                                                         DATE OF PERMIT ISSUANCE—  03/04/81
 PERMIT NO. MAN-10-GEB-81-68-002                                                                 ESTIMATED DATE OF START-UP--
 DETERMINATION MADE BY       WISCONSIN DNR                  EMILIA ESTRADA                      (608)-266-024
-------
                                             APPENDIX ~  DETAILED  SOURCE  LISTING
                                                                                                                        C5/2C/1964




SOURCE TYPE/SIZE—         SOLVENT DECREASING


COMPANY NAME/SITE LOCATION  REGAL INTERNATIONAL,  INC.                                             >  TX

                           „ — -.___	— —	—	— — —	— __ — _._ —	___ — _	_ — ,.____...._.. — — — — .- —	— —	— — —	_ — — — _ — _ — —	— —	—

DETERMINATION IS BACT FOR A NEW SOURCE.                                                       DATE  OF PERMIT ISSUANCE--  09/22/82
PERMIT NO. X-3641                                                                             ESTIMATED DATE OF START-UP—   1978
DETERMINATION MADE BY       TEXAS ACS                      ART KELLOGG                        (512)-451-5711
                             (AGENCY)                   (AGENCY CONTACT PERSON)                   (PHONE)



PROCESSES SUBJECT                     THROUGHPUT         POLLUTANT     EMISSION LIMITS                                    ... & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
	*.-	•	

PAINT SPRAYIUS                    49920.00 LB/YR
                                                           VOC       4.0000  T/YR
VAPOR DECREASING                  18460.00 LB/YR
                                                           VOC       1.1500  T/YR
                                                                            COOLING COILS


NOTES 	
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 294
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW STATUS;   05/04/1954
ID NUMBER TX-0132
                                                     SOURCE TYPE CCDE
                                                                         4.9

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                         05/22/1984



SOURCE TYPE/SIZE—         GRAPHIC ARTS
                           _,._-.	_--„	_„___	__	__	___ —	„_	-_-.__.._____-.___.___.»____,._	_.,..____..____	...- — ..,.__.._..___.,..__

COMPANY NAME/SITE LOCATION  BEMIS CARPHANE FILMS                                           OSHKOSH, WI
                           --- — __-_---__	--------•------------ — — »-- — ---«- — -----.---- — — - — — --- — __-_» — — -,___„__._._»__.__. _.«._._,____.___

DETERMINATION IS LAER FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—  08/25/81
PERMIT NO. MAN-10-EYE-81-71-083                                                                ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY       WISCONSIN DNR                  EMILIA ESTRADA                      (608)-266-0244
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... &  BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT  EFF


SARAN COATERS, 2 EA
                                                           VOC       0.3200 KG/L                                              LAER
                                                                     2.6700 LB/GAL
                                                                            LOW SOLVENT COATING


NOTES 	
OFFSET FROM SHUTDOWN OF 814 LAMINATOR AT CURWOOD, NEW LONDON
(*> INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 295
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS;  ovoi-^sj
                                                      ID NUH3ER WI-0003
                                                                                                           SOURCE TYPE CODE   4.12

-------
                                             APPENDIX -- DETAILED SOURCE LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE—
                            GRAPHIC ARTS
COMPANY NAME/SITE LOCATION  BEMIS CO.
                                                                                           OSHKOSH,  WI
DETERMINATION IS LAER FOR A NEW SOURCE.
PERMIT NO. MAN-03-80-71-125
DETERMINATION HADE BY       WISCONSIN DNR
                             (AGENCY)
   EMILIA ESTRADA
(AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE —  11/13/80
                                       ESTIMATED DATE OF START-UP— •
                                                                                                   ( PHCNE )
PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ...  & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ...  PCT EFF
	

FLEXOGRAFHIC PRINTING PRESS *8
                                                           VOC      85.0000 7. REDUCTION                                      LAER
                                                                            LOW SOLVENT COATINGS
EXTRUSION COATER 89
                                                           VOC       0.0900 KG/L                                             LAER
                                                                     1.5600 LB/GAL
                                                                            LOW SOLVENT COATINGS
LAMINATOR 816
                                                           VOC       0.1700 KG/L                                             LAER
                                                                     1.4300 LB/GAL
                                                                            LOW SOLVENT COATINGS


NOTES 	
OFFSET FROM CLOSING 81 SARAN COATER « LAMINATOR Sll










                                                                                                      INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FCR THIS TABLE.                                        REVIEW  STATUS:   04/01/1933

PAGE G- 296                                          ID  NUMBER  WI-0002                                    SOL'RCE TYPE CODE    4.12

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/22/1984
SOURCE TYPE/SIZE—
                            GRAPHIC ARTS
COMPANY NAME/SITE LOCATION  BEMIS SPECIALTY  FILMS
                                                     OSHKOSH,  HI
DETERMINATION IS LAER FOR A NEW SOURCE.
PERMIT NO. KAN-10-EYE-81-71-082
DETERMINATION MADE BY       WISCONSIN DNR
                             (AGENCY)
                     EMILIA ESTRADA
                  (AGENCY  CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE—  12/21/81
                                       ESTIMATED DATE OF START-UP—•
                                       <608)-266-0244
                                           (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
...  &  BASIS
...  PCT EFF
LAMINATOR 817
COATER S10
COATER *11
FLEXOPRESS COATER 82
                     VOC       0.0400 KG/I COATING
                               0.3300 LB/GAL
                                      LOW SOLVENT COATINGS

                     VQC       0.0300 KG/L COATING
                               0.2500 LB/GAL
                                      LOW SOLVENT COATINGS

                     VOC       0.2100 KG/L
                               1.7700 LB/GAL
                                      LOU SOLVENT COATINGS

                     VOC      18.0000 7. VOC VOL.  IN IKK
                                      LOW SOLVENT COATINGS
                                                                                                                             LAER
                                                                                                                             LAER
                                                                                                                             LAER
                                                                                                                             LAER
NOTES 	
OFFSET FROM SHUTDOWN OF 814 LAMINATOR 4 82  SARAN COATER AT CURWOOD, NEW  LONDON
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE 6- 297
                                                                INITIAL REVIEW  POST STARTUP
                                                   REVIEW STATUS;  04/01/1933
                                                      ID NUMBER WI-0004
                                                                                                           SOURCE  TYPE  CCDE    4.12

-------
                                             APPENDIX ~ DETAILED  SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE—         GRAPHIC ARTS                                                     102.00 GAL INK/H
                           	_.	.	

COMPANY NAME/SITE LOCATION  BROWN PRINTING                   '                             FRANKLIN, KY 42134
                            P.O. BOX 451                                                                            SIMPSON COUNTY
                           ______	_	_ — _ _	__ —__________ — ______ — — — _ — — —— — — — — —— — — — — —— — — — — —— — — —— — — --—•- — — — — — -•-••- —— —	——————	— — — — — ..-.

DETERMINATION IS LAER FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—  07/28/80
PERMIT NO. C-80-95                                                                             ESTIMATED DATE OF START-UP—   1931
DETERMINATION MADE BY       KENTUCKY DAPC                  BILL DILLS                          (502)-564-3382
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PKOHE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION LIMITS                                   ... * BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF


ROTOGRAVURE PRINTING PRESS          102.00 GAL/H INK
                                                           VOC     102.0000 GAL/H INK                                        LAER
                                                                            CARBON ADSORPTION                                97.00


NOTES 	
CHANGING THINNER USAGEi BUT LIMITING INK TO 102 GAL INK/HOUR.  7 UNITS, BACT/LAER WILL BE DETERMINED USING A PHASED APPROCH.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- £98
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW STATUS--  04/01/1933
ID NUMBER KY-0015
                                                     SOURCE TYPE CODE   4.12

-------
                                            APPENDIX -- DETAILED SOURCE LISTING
                                                                                                                        05/23/1984



SOURCE TYPE/SIZE—         GRAPHIC ARTS


COMPANY NAME/SITE LOCATION  COLUMBUS COATED  FABRICS                                       COLUMBUS, OH


DETERMINATION IS LAER FOR A MODIFIED SOURCE.                                                   DVTE OF  PERMIT ISSUANCE—  04/29/81
PERMIT NO. 01-415                                                                             ESTIMATED  DATE OF  START-UP--
DETERMINATICN MADE BY       OHIO EPA CD                    VICTOR FISHER                       (614)-864-3195
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROU3HPUT         POLLUTANT     EMISSION  LIMITS                                    ...  4 BASIS
TO THIS PERMIT                        CAPACITY          EMITTED             CONTROL EQUIPMENT OR  PROCESS  MODIFICATION  ...  PCT EFF


INTA-ROTO HL-41 PRINTER               7.00 MT1YD/YR
                                                          VOC        4.8000  LB/GAL VINYL                   «                 BACT
                                                                     2.9000  LB/GAL INK
                                                                            COAT  COMPOSIT.<252 SOLV,BY  VOL                    70.00


NOTES 	
LIMITS IMPOSED BY PERMIT TO INSTALL, WHICH ALSO REQUIRES NEW  PERMIT  APPLICATION IF SOLVENT  COMPOSITION  OR SCHEDULE ARE CHANGED
(*> INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 299
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS;  04/01/1033
                                                      ID NUM3ER  OH-0033
                                                                                                           SOURCE TYPE CODE   4.12

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/198*
SOURCE TYPE/SIZE	
                            GRAPHIC ARTS
                                                                                             360.00 T/YR
COMPANY NAME/SITE LOCATION  CONTAINER CORP. OF AM
                                                                                            MUHCIE, IN
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT NO. PC(18)1*77
DETERMINATION MADE BY       INDIANA APCD
                             (AGENCY)
                     FRANK PROFIT
                  (AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE—  10/31/80
                                       ESTIMATED DATE OF START-UP--
                                       (317J-633-066*
                                           (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
& BASIS
PCT EFF
ROTOGRAVURE PRINT PRESS
                                    362.00 T/YR VOC
                                                           voc
                                                                    36.0000  T/YR
                                                                            FUME  INCINERATOR
                                                                                                                             90.00
NOTES 	
OPERATES 62*0 MRS/YEAR
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 300
                                                      ID NUMBER  IN-0018
                                                                INITIAL  REVIEW  POST  STARTUP
                                                   REVIEW STATUS:   04/01/1°33

                                                                     SOSJPCE  TYPE CCOE   *.12

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                         05/22/198*
SOURCE TYPE/SIZE— GRAPHIC ARTS
COMPANY NAME/SITE LOCATION CPS INDUSTRIES
DETERMINATION IS LAER FOR A NEW SOURCE.
PERMIT NO. (REGION FILE NO.) FSD-TN-069
DETERMINATION MADE BY TENNESSEE APCO
(AGENCY)
PROCESSES SUBJECT THROUGHPUT
TO THIS PERMIT CAPACITY
CERUTTI & HELIX PRESSES, 5 1073.30 L8/H TOTAL
1073.30 LB/H
FRANKLIN, TN
DATE OF PERMIT
ESTIMATED DATE
ANN NIELSON ( 615)-741-3651
(AGENCY CONTACT PERSON) { PHOHE )

WILLIAMSON COUNTY
ISSUANCE--
OF START-UP —
POLLUTANT EMISSION LIMITS ... t BASIS
EMITTED CONTROL EQUIPMENT OR PROCESS MODIFICATION ... PCT EFF
VOC 128.1100 LB/H
SOLVENT REC. SYS & CARBON. BED
LAER
84.00
NOTES
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.


PAGE G- 301
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS:  04/01/1933
                                                      ID  N'JIIBER  TN-0005
                                                                                                           SOURCE TYPE CODE   4.12

-------
                                             APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                         05/23/198*



SOURCE TYPE/SIZE—         GRAPHIC ARTS                                                     2400.00 T/YR


COMPANY NAME/SITE LOCATION  DIVERSIFIED PRINTING                                            BACKSON, TN 37055
                            DICKSON CORAMY INDUSTRIAL PARK                                                           DICKSON COUNTY


DETERMINATION IS LAER FOR A NEH SOURCE.                                                         DATE OF PERMIT ISSUANCE—  03/10/81
PERMIT NO. PSD-TN-069                                                                           ESTIMATED DATE OF START-UP—   1982
DETERMINATION MADE BY       TENNESSEE APCD                 ANGIE PITCOCK                        (615J-741-3651
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                    .. .  & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ...  FCT EFF
^ — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —— — — — — — — — — — — — -- — — — -- — — — -. — — -- — -- — — — — — — — — — -. — — — — —.-. — — — -. — — — —. — — —.—.—._ — _,-- —___ — — ___» — __._„_,__»_.___„__.__„____._____._

PRINTING
                                                           VOC    £400.0000 T/YR                                              LAER
                                                                            CARBON ADSORPTION                                 64.00


NOTES 	
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 302
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS:  04/01/1983
                                                      ID NUMBER TN-0002
                                                                                                           SOURCE TYPE CODE    4.12

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/32/1984



SOURCE TYPE/SIZE—         GRAPHIC  ARTS                                                    2000.00 FT/MIN


COMPANY NAME/SITE LOCATION  R.  J.  R.  ARCHER,INC.                                     WINSTON-SALEM, NC
                            220 E. POLO RO


DETERMINATION IS BACT FOR A MODIFIED  SOURCE.                                                   DATE OF PERMIT ISSUANCE-
PERMIT NO. 00466-0005-P                                                                       ESTIMATED DATE OF START-UP--
DETERMINATION MADE BY       FCSSYTH  COUNTY  EKV. AFFAIRS    KEITH TART                          (919)-7£7-8S60
                             (AGENCY)                  (AGENCY CONTACT PERSON)                    (PHONE)
PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ...  * BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ...  PCT  EFF


ROTOGRAVURE PRESS                  2630.00  LB/H PAPER
                                                          VOC     341.0000 LB/H
                                                                           CARBON ADSORB. SYS  & RECOVERY  SYS                69.00


NOTES 	
LOCAL PERMIT TO CONSTRUCT WAS NOT ISSUED. R.J.R. ARCHER, INC. REQUESTED TERMINATION OF PSD EVALUATION  BECAUSE  THEY  CONTROLLED
THE MAJORITY OF THE EXISTING PLANT AND THE  OFFSET GENERATED WOULD ELIMINATE THE REQUIREMENTS OF A  PSD  ANALYSIS.
                                                                                                      INITIAL  REVIEW  POST STARTUP
(») INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEW  STATUS:   04/01/1933

PAGE G- 303                                           ID NUMBER NC-0026                                     SOURCE  TYPE COCE   4.12

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                         05/22/1 
-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/198*



SOURCE TYPE/SIZE—         GRAPHIC ARTS                                                    5860.00 LB/H


COMPANY NAME/SITE LOCATION  SOUTHWEST COLOR PRINTING CORP.                                         , TX
                                                                                                                   ANGELINA COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—  09/22/82
PERMIT NO. C-9131                                                                              ESTIMATED DATE OF START-UP—    1983
DETERMINATION MADE BY       TEXAS ACS                      ART KELLOGG                         (7I3J-634-3357
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... * BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   .. . PCT EFF
— — — — — — — — — — — — — — — — — — •« — .— •— — .— — •.,. — — __• _____,._ — — _*—.__ — _•,_« __ __ __»»—._ — • ,, __-, ___ ______ ». _ __„ __ _•, -, _ _ _*.___ „ _ _ ., _ — — _ _ _ .._ ___„ v ^. _. ». v — _«.«.__»^__ — _»_»._

OFFSET PRINTERS, 2                 5860.00 LB/H PRODUC*
                                                           VOC     204.0000 T/YR SEE NOTE
                                                           NOX       3.5000 T/YR SEE NOTE


NOTES 	
NOTE-THESE EMISSION LIMITS ARE WITHOUT CONTROLS. IN LIEU OF ADD-ON CONTROL DEVICES THIS SOURCE IS REQUIRED TO CONVERT TO  HIGH-
SOLIDS OR WATER-BORNE INKS WHEN THEY ARE DEMONSTRATED TO BE SATISFACTORY FOR USE IN THE INDUSTRY.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 305
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS;
                                                      ID NUMBER TX-0131
                                                                                                           SOURCE TYPE CODE   4.12

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/22/198*
SOURCE TYPE/SIZE	
                            GRAPHIC ARTS
                                                                                             32.00 LB/H  INK
COMPANY NAME/SITE LOCATION  UNITED COLOR PRESS
                            351 GARVER RD
                                                                                           MONROE, OH
                                                                                        BUTLER COUNTY
DETERMINATION IS
PERMIT NO. 18-176
DETERMINATION MADE BY
SOUTHWEST OHIO APCA
 (AGENCY)
PROCESSES SUBJECT
TO THIS PERMIT
          THROUGHPUT
           CAPACITY
   RAY SILBERNAGEL
(AGENCY CONTACT PERSON)
                          DATE OF PERMIT ISSUANCE—  09/17/83
                          ESTIMATED DATE OF START-UP--   1983
                          1513)-251-S777
                              (PHCNE)
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
* BASIS
PCT EFF
OVEN i PRESS, TITAN
                                     32.00 LB/H INK
                                                           VOC
                                        90.0000  '/. CONTROL
                                                CATALYTIC INCINERATOR
                                                                     TECH
                                                                     92.00
92XEDESTRUCTION~EFFICIENCY DEMONSTRATED, CAPTURE EFFICIENCY UNDETERMINED.  THE  SOURCE WAS MOVED  FROM PREVIOUS  LOCATION,  TRIGGER
ING NEW SOURCE REVIEW REQUIREMENTS.
 (*> INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

 PAGE G- 306
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW STATUS;
                          ID NUMBER OH-0061
                                                                               SOURCE TYPE CODE   4.12

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/22/1984
SOURCE TYPE/SIZE—         GRAPHIC ARTS


COMPANY NAME/SITE LOCATION  WORLD COLOR PRESS                                                SALEM, IL
                                                                                                                    MARION COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT  ISSUANCE—   01/13/82
PERMIT NO. C 80 10 0006                                                                       ESTIMATED DATE  OF START-UP—    1980
DETERMINATION MADE BY       ILLINOIS EPA                   CHRIS ROMAINE                       (217 )-782-2113
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT         POLLUTANT    EMISSION  LIMITS                                    ... 4 BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF


ROTOGRAVURE PRESSES
                                                          VOC     336.0000 T/YR                                             BACT
                                                                           CARBON ADSORPTION SYSTEM                         94.00
OFFSET PRESSES
                                                          VCC     251.0000 T/YR                                             BACT
                                                                           AFTERBURNER SYSTEM                               90.00
                                                                           OR EQUIVALENT SYSTEM


NOTES 	
l.BACT RETROSPECTIVELY APPLIED  WHEN PSD PROJECT BROUGHT  TO LIGHT BY APPLICANT. 2.EFFECTIVENESS OF AFTERBURNERS FOR OFFSET  PRES
SES IS BEIN3 INVESTIGATED WITH  TRIAL PROGRAM ON ONE PRESS TO BE CONCLUDED 9/84. EVALUATING ADD ON
CONTROLS VS. REDUCTIONS ACHIEVED THROUGH REFORMULATION OF INK AND FOUNTAIN SOLUTION.  LIMITS WILL BE ADJUSTED ACCORDINGLY.
(*) INDICATES DATUM WAS TRUNCATED FOR  THIS TABLE.

PAGE G- 307
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS:  oPE  CODE    4.12

-------
                                              APPENDIX — DETAILED SOURCE LISTING
                                                                                                                         05/22/1984
 - = = = = = = = = = = = r === = = r = = = === === = = = = = = = = === = = = = = = = = = = = : = === = = = = = = = = = = = = = = = = === = = = = = = = === = = ==== = _ = = = = = = = = = = = = = = = === = = = = = = _== = = :: = = = = = = = =



 SOURCE TYPE/SIZE—         GRAPHIC ARTS                                                     120.00 MMBTU/H
                            	

 COMPANY NAME/SITE LOCATION  H.F. HALL PRINTING CO.                                           EVANS, GA
                             4310 EVANS TO LOCK RD
                            "~  """""*     ~"~"  ~"  —   "••"	— — — — — — — — — — — — — — — — — — — —	— — — — — _ — . — _— — __^_	....	_	__ — -. — — — ..._	— -. — — -, — _.— _ — «._	—— —

 DETERMINATION IS BACT FOR A NEW SOURCE.                                                         DATE OF pERMIT ISSUANCE--  10/04/82
 PERMIT NO.  2754-036-8480                                                                        ESTIMATED DATE OF START-UP-   1981
 DETERMINATION MADE BY       GEORGIA EPD                     BILL FARRISEE                       <404)-656-4867
                              (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)

 = = = = = = = r = = rr = = = = ;r = = = r = = : = = = r = = r = = = r = r = = = rr = = = = = = r = : = = ::: = r = = r = = = r = = = = = = r = = r = :: = r = = = =:: = r = r= = r === = = r = = = = r = = = = = r = = = = = = = = = = = = :::: = = = = = = = =

 PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ...  S BASIS
 TO THIS PERMIT                        CAPACITY           EMITTED            CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ...  PCT EFF
BOILERS, 2
CARBON BED ADSORPTION UNIT
                                      60.00 MMBTU/H
                                    513.00  LB/H VOC
PM

S02



VOC

CO
NOX
  0.1000 LB/MMBTU
         BOILER DESIGN
246.0000 LB/H
  O.SOOO LB/MKBTU
         BOILER DESIGN

 39.0000 LB/H
         CARBON ADSORPTION SYSTEM

  0.3000 LB/Mf-tBTU
         BOILER DESIGN
                                                                                                                              NSPS

                                                                                                                              NSPS
                                                                                                                              LAER
                                                                                                                              95.00

                                                                                                                              NSPS
NOTES 	
PERMIT AMMENDED TO COVER TWO BOILERS INSTEAD OF THREE BOILERS IN ORIGINAL PERMIT AND TO COVER USE OF NO.6  FUEL  (2  17. SULFUR)  I
NSTEAO OF NO.6 FUEL ( . 9X SULFUR) IN ORIGINAL PERMIT.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 308
                                           INITIAL REVIEW  POST STARTUP
                              REVIEW STATUS:  04/01/1983
                                                      ID NUMBER GA-0013
                                                                                                           SOURCE TYPE CODE    4.12

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984
 SOURCE TYPE/SIZE—
                            OTHER ORGANIC EVAPORATION LOSS
                                                                                             300.00 GAL TOPCOAT/D
COMPANY NAME/SITE LOCATION  BROYHILL FURNITURE
                                                                                            NEWTON,  NC
                                                                                                                    CATAKBA COUNTY
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT NO. NC-035
DETERMINATION MADE BY       NORTH CAROLINA DEN
                             (AGENCY)
                     MIKE SEWELL
                  (AGENCY CONTACT PERSON)
DATE OF PERMIT ISSUANCE-
ESTIMATED DATE OF START-UP--
(919J-733-61E6
    (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ...  * BASIS
 CAPACITY          EMITTED             CONTROL EQUIPMENT OR PROCESS MODIFICATION  ...  PCT EFF
SPRAY BOOTHS
                                                           VOC      688.0000  T/YR
                                                                            NONE
                                                                            EQUIPMENT  DESIGN &  OPERATION
                                                                                       BACT
NOTES 	
11 SPRAY BOOTHS
<*) INDICATES DATUM WAS TRUNCATED FOR  THIS TABLE.

PAGE G- 309
                                                                INITIAL  REVIEW   POST STARTUP
                                                  REVIEW STATUS;   04/01/1933
                                                     ID NUMBER NC-0014
                                                                                                          SOURCE TYPE  CODE

-------
*T*   3003 3dJU 33anOS
===============z=======r========r=z=============s=:
                           :S(UV1S M3IA33
tuutfvis isoa  H3ZA3tt IVXIZHZ
                                                         esoo-HO itaeunN 01
                                                                   OK -a
                                                                  ========
                              •ansvi situ aoj oaiv3Mnai SVM Mtuva saivaxoHi c«>
HA/1 OOSZ't
                                                                  3QA
                                     M'OOOI
                                                                                                   saaruxu nen 'asm SNUMU
                                                                    *ON
JJ3 13d •••  NOJ1V3IJIOOM SS330iU HO lNBWint)3 1CHUN03           03111113          JHI3VdV3                        UWOgf SHU. Ol
szsva t • • •                                  sinm Nozsszua    iwinmod        ifuusnoiMi                    xaarons sassaaoaj

==s====r======r===============r=======s====z=zz========s==r========:

                        laNOHdl                    INOSlQd 13V1N03 A3N39V1                  CA3N39V1
                     COS£-^99-t 912)                          8ZQVN 3XZ                3riVO ONV13A3J13      18 3QTU
       --dn-lOTlS JO 31VQ O31Vt4IlS3
          ~33wnssi iztraM jo itva                                                      -33dnos ION v au iova sx


                                                                                     OB H010S OS£*2
                      9»I*» NO 'S1H OHCUOaQ                           'OS 9JM t HEWdZflba lN33S3OOmj  MOX1V3O1


                                                                      ssori NOiivaodVAa outran 
-------
                                             APPENDIX — DETAILED  SOURCE LISTING
__			               _                                                                          05/22/1984



SOURCE TYPE/SIZE—         OTHER ORGANIC EVAPORATION LOSS


COMPANY NAME/SITE  LOCATION  GUARDIAN INDUSTRIES CORP.                                              , TX
                                                                                                                     NAVARRO COUNTY
                           •" — ""• •— — — »-» — — — «._•_ _•__ —__„ —,„.•...*__ —.....•. — — •..• — _ _ _,„.._ — — _ __ — „_ •••__ • »._„__ .... __ _ — _ «..._ _.•.»„._„_ ___.^__ — — ».«.___ ___________

DETERMINATION IS BACT FOR A NEW SOURCE.                                                         DATE OF PERMIT ISSUANCE—  06/C8/83
PERMIT NO. X-4293                                                                               ESTIMATED DATE OF START-UP—   1933
DETERMINATION MADE BY       TEXAS ACS                      ROBERT  MAUEL                        (512)-451-5711
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION LIMITS                                    ...  * BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT OR PROCESS MODIFICATION   ...  PCT EFF


COATING APPLICATOR
                                                           VOC               NONE
                                                                             VACUUM SPUTTERING MACHINE


NOTES 	
(*) INDICATES DATUM WAS TRUNCATED F03 THIS TABLE.

PAGE G- 311
      •" TTTH REVIEW   POST STARTUP
blATUS-  05/04/1934

           C~_~_L T;"E CCDE   4.14

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                         05/22/1984



SOURCE TYPE/SIZE---         OTHER ORGANIC EVAPORATION LOSS


COMPANY NAME/SITE LOCATION  MEREDITH CORP.                                              DES MOINES, IA
                           _	_ —	___„„	—	..-._.. — —	— — -. — — — —	— — — — — —	— — .. — -. — —	— — — -. — — -. —	— _ — _„_ — — — — _ — — — — — — -. — — -. —	.._ — — — — — — _..

DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE— 04/15/82
PERMIT NO.                                                                                     ESTIMATED DATE OF START-UP-
DETERMINATION HADE BY       EPA REGION VII                 STEVE KOVAC                         (816)-374-6525
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ...  & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED         .   CONTROL EQUIPMENT OR PROCESS MODIFICATION   ...  PCT  EFF
. —	____	— _ — — — — — _.. — —	„_-.	— — — -._ —	— _„._-.	— -.- — ,_ — _	— — —	— — . — — —	_ — — —	__., — _ — —	—— __	_,..- — —	— —	— — — — —	—

ROTOGRAVURE PRINTING PRESS         1614.00 LB/H SOLVENT
                                                           VOC      16.0000 •/. VOL SOLVENT USED
                                                                            SOLVENT RECOVERY SYSTEM                          95.00
FLEX03RAFHIC PRINTER


NOTES 	
THE FLEXOC-3AFHIC PRINTER SHALL NOT USE A RAW INK (OR RELATED COATING) WITH A RATIO OF VOC VOLUME CONTENT TO SOLIDS VOLUME CONT
ENT WHICH IS GREATER THAN 0.64 NOR SHALL RAW INK BE DILUTED WITH ANYTHING OTHER THAN WATER ADDITION.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 312
                                                                                                      INITIAL REVIEW   POST  STARTUP
                                                                                         REVIEW STATUS:   04/01/1933
ID NUMBER IA-0009
                                                     SOURCE TYPE CODE    4.14

-------
                                            APPENDIX -- DETAILED SOURCE  LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE—
                            OTHER ORGANIC EVAPORATION  LOSS
COMPANY NAME/SITE LOCATION  MR.  SPA,  INC.
                                                   CAMARILLO,  CA
                                                                                                                    VENTURA COUNTY
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT NO. 1240-1
DETERMINATION MADE BY       VENTURA COUNTY APCD
                             (AGENCY)
                     KEITH DUVAL
                  (AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE—  09/08/83
                                       ESTIMATED DATE OF START-UP—   1983
                                       (805)-654-2664
                                           (FHONE)
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT    EMISSION LIMITS                                   ... « BASIS
 EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
FIBERGLASS-POLYESTER RESIN APPL*   3093.00  LB/D RESIN
                                                          VOC
                                                                   120.0000  LB/D
                                                                            SEE NOTE
NOTES 	
FILE A 340-A013. INCREASE STYRENE CONTENT  IN GEL COAT TO  ELIMINATE NEED  FOR ACETONE  DILUTION,  USE  OF  FILLER  MATERIAL IN RESIN
FOR DISPLACEMENT, VAPOR SUPPRESENT IN RESIN.
(*) INDICATES DATUM WAS TRUNCATED FOR  THIS TABLE.

PAGE G- 313
                                                                INITIAL REVIEW  POST STARTUP
                                                   REVIEW STATUS:   04/26,1934
                                                     ID NUMBER CA-0060
                                                                                                           SOURCE  TYPE  CODE    4.14

-------
                                             APPENDIX —  DETAILED  SOURCE  LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE—         OTHER ORGANIC EVAPORATION LOSS


COMPANY NAME/SITE LOCATION  PPG INDUSTRIES, INC.                                          CLEVELAND,  OH  44111
                            3800 WEST 143 ST.


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE  OF  PERMIT ISSUANCE—  01/06/84
PERMIT NO. 13/18/00/0101,SEE N*                                                                ESTIMATED DATE OF  START-UP—    19S4
DETERMINATION MADE BY       CLEVELAND DAPC                 IKE  HABIB                            (216)-664-3503
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION LIMITS                                   ... t  BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL  EQUIPMENT  OR  PROCESS MODIFICATION   ... FCT EFF


ENTIRE PLANT, SEE NOTE 82
                                                           VOC
                                                                            THERMAL  INCINERATOR SYSTEM                        90.00
                                                           ODOR
                                                                            THERMAL  INCINERATOR SYSTEM                        90.00
FUGITIVE EMISSIONS
                                                           PM      898.0000  T/YR
                                                                            UNCONTROLLED


NOTES 	
NOTE - SOURCE * P001-P004, P008-P010, P013-P015,  P017,  P019-P022,  P024- P029,  P032,  P033,  P035-P040,  P043-P046, 4 T116-T122.  N
OTE S2 - INCLUDES SAND MILLS, ATTRITION HILLS,  CCHLES 4 HCCKMEYER  MIXERS,  BATCH  BLENDING  TANKS,
TANK & TOTE BIN CLEANING BOOTHS.









                                                                                                     INITIAL REVIEW   POST STARTUP
(*> INDICATES DATUM KAS TRUNCATED FOR THIS TABLE.                                         REVIEW STATUS:

PAGE G- 314                                           ID  NUMBER OH-0059       ,                              SOURCE TYPE CCCE    4.14

-------
                                            APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE—
                            OTHER ORGANIC EVAPORATION  LOSS
COMPANY NAME/SITE LOCATION  ROCKWELL INTERNATIONAL
                                                                                            TULSA, OK
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT NO. T80-43
DETERMINATION MADE BY       TULSA CITY-COUNTY HEALTH DEPT  BILL GIBBONS
                             (AGENCY)                   (AGENCY CONTACT  PERSON)
DATE OF PERMIT ISSUANCE—  07/08/80
ESTIMATED DATE OF START-UP—   1981
(918)-744-1000
    (PHONE)
PROCESSES SUBJECT                     THROUGHPUT         POLLUTANT     EMISSION  LIMITS                                    .. .  « BASIS
TO THIS PERMIT                         CAPACITY           EMITTED            CONTROL EQUIPMENT  OR  PROCESS MODIFICATION  ...  PCT EFF


CHEM MASKANT ON ACFT SKINS                 NOTE *1
                                                          VOC      202.0000 T/YR UNCONT..NOTEB2
                                                                           CARBON ADSORPTION                                 90.00
BOND PRIME, PRIME & ENAMEL COAT*           NOTE #1
                                                          VOC       18.4000 T/YR UNCONT.,NOTE*2
                                                                     3.4000 T/YR CONT.,NOTES2
                                                                           CARBON ADSORPTION  UNITS                           80.00


NOTES 	
1) MASKANT & COATINGS RELATED TO COMMERCIAL AIRCRAFT BODY SECTION  PRODUCTION,  PERMIT  LIMITS  PRODUCTION TO 144 SHIP  SETS PER YE
AR.
2) BATCH TYPE COATINGS OPERATIONS NEGATES MEANINGFUL HOURLY EMISSION RATE.











                                                                                                      INITIAL REVIEW  POST  STARTUP
(*> INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:   04/01/1
-------
                                             APPENDIX —  DETAILED SOURCE LISTING
                                                                                                                        05/22/198*
SOURCE TYPE/SIZE	         OTHER ORGANIC EVAPORATION LOSS


COMPANY NAME/SITE LOCATION  SOLVENT RESOURCE RECOVERY                              WEST CARROLLTON,  OH
DETERMINATION IS LAER FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—  07/07/82
PERMIT NO. 0857751346 P004                                                                     ESTIMATED DATE OF START-UP—   1983
DETERMINATION MADE BY       RAPCA - DAYTON,OH              GORBY LEE                           (5131-225-4435
                             (AGENCY)                   (AGENCY  CONTACT PERSON)                    (PHONE)
PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ...  i B4SIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT OR PROCESS MODIFICATION  ...  PCT EFF
— _«._„, — ___,. — .__ — _ — _«._ _ ___ _ — _~- ~ _ _ — — — — — _«_ — — — — — — — — — ___.. _ «__ m. ~ __ V — — ____.. ~ __ — — ~_- _»»____.*,•__.— «.__ — —-.»— — — — — — — ————-!•——• — — — •- — ^ — —— — ——— — — — — *— — _ — — —


DISTILLATION UNIT                300000.00 GAL/YR
                                                          VOC        1.2700 LB/D
                                                                     0.1600 T/YR
                                                                            CONDENSORS                                       99.99



NOTES 	
DISTILLATION UNIT IS OPERATED WITH CONDENSORS WHICH ARE  150X OF DESIGN CAPACITY.
                                                                                                      INITIAL REVIEW  POST STARTUP
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEW STATUS:   04/01/1983    02/13/1934
PAGE G- 316                                           ID NUMBER OH-0044                                    SOURCE TYPE CODE   4.14

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/22/1984



SOURCE TYPE/SIZE—         OTHER ORGANIC  EVAPORATION LOSS


COMPANY NAME/SITE LOCATION  U.S.  AVIEX CO.                                                   MILES, MI 49120
                            1800  TERMINAL  ROAD


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT  ISSUANCE—   10/14/83
PERMIT NO. 260-83                                                                             ESTIMATED DATE  OF START-UP—    19S3
DETERMINATION MADE BY       MICHIGAN DNR                   ASAD KHAN                           (517)-322-1333
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                    ... t BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF


CONTAMINATED GROUND WATER CLEAN*     200.00 GPfl
                                                          1,1*     16.9100 MG/CU METER
                                                                           3  - 1000 CFM CAP. ADSORPTION UNITS              90.00
                                                          CAR*      5.3400 MG/CU METER
                                                          TRI*      2.6700 MS/CU METER
                                                          CHL*      0.0900 MG/CU METER
                                                          VOC      28.4700 MG/CU METER


NOTES 	
VOC DETERMINED BY BACT REQUIREMENTS PER STATE REGULATIONS.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 317
                                                                                                      INITIAL  REVIEW  POST STARTUP
                                                                                        REVIEW STATUS;   04/19/1934
                                                      ID NUMBER MI-0034
SOURCE TYPE CODE   4.14

-------
                                             APPENDIX —  DETAILED  SOURCE LISTING
                                                                                                                        05/32/1934



SOURCE TYPE/SIZE—-         PETROLEUM REFINING - SEPARATION                                  450.00  HMBTU/H


COMPANY NAME/SITE LOCATION  ARCO PETROLEUM PROD. CO.                                         CARSON,  CA


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE  OF PERMIT ISSUANCE—  04/06/79
PERMIT NO. (REGION FILE NO.) LA-78-17                                                          ESTIMATED  DATE OF  START-UP-
DETERMINATION MADE BY       EPA REGION IX                  RICK  SUGAREK                        (415)-974-8058
                             (AGENCY)                   (AGENCY  CONTACT PERSON)                    ( PHOS'E )



PROCESSES SUBJECT                     THROUGHPUT       POLLUTANT     EMISSION LIMITS                                    ...»  BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS  MODIFICATION  ... PCT EFF


DISTIL. UNIT, REPLACEMENT CRUDE     450.00 MMBTU/H HEA*
                                                           S02      800.0000  PPM  S  REFIN.  GAS
                                                                     0.2500  •/. S  FUEL  OIL
                                                                            SULFUR-IN-FUEL


NOTES 	
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 318
                                                                                                     INITIAL REVIEW  POST STARTUP
                                                                                        REVIEW STATUS:  04/01/19S3     C4/C4/19S4
ID NUMBER CA-0017
                                                     SOURCE TYPE CC2E    5.1

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/198*



SOURCE TYPE/SIZE	         PETROLEUM REFINING - SEPARATION


COMPANY NAME/SITE LOCATION  GULF STATES OIL « REFINING CO.                           CORPUS CHRISTI, TX
                                                                                                                     NUECES COUNTY
                           — — «"• — — — — — — -. — — -.*. — — — — -. — — — — — ___._.._ ._._._ .*_..»___*._ _«.__. ..._...__..___ _____ _____ «_____ ..-._____ —,_•__ — — — __ __„__ — •

DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—  12/04/80
PERMIT NO. 8452                                                                                ESTIMATED DATE OF START-UP—   1981
DETERMINATION MADE BY       TEXAS ACS                      STUART KEIL                         (5121-451-5711
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ...» BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF


HEATERS, 4                          109.00 MMBTU/H
                                                           S02      32.9000 T/YR                                             BACT
                                                                            NONE - LOW SULFUR FUELS
                                                           NOX      19.5000 T/YR                                             AP42
FUGITIVE EMISSIONS
                                                           VOC       3.1000 T/YR                                             BACT
                                                                            MONITORING * MAINTENANCE                         75.00
VAC. COLUMN EJECTOR               16000.00 B/D FEED
                                                           VOC              NONE
                                                                            VAPORS TO FUEL SYSTEM                           100.00


NOTES 	
VACUUM COLUMN VAPORS ROUTED TO FUEL SYSTEM, STEAM CONDENSATE TO DESALTER. CONSIDERED AS A CLOSED SYSTEM.









                                                                                                      INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS'-  OV01/1983

PAGE G- 319                                           ID NUMBER TX-0087:                                   SOURCE TYPE CODE    5.1

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                         05/22/1984



SOURCE TYPE/SIZE—-         PETROLEUM REFINING - SEPARATION                                   400.00  MHBTU/H
                           		•	

COMPANY NAME/SITE LOCATION  THE DOW CHEMICAL CO.                                           FREEPORT,  TX
                                                                                                                    BRAZORIA COUNTY
                            _         _«. ____•___ — _..____ — — ————— ____»_.. _ — — — -- — ..____ ___ _____-,__ __—__—_—— — — — __— — —.— «, — _—-.-. — — — __ — •.«.—.———. — —-.

DETERMINATION IS BACT                                                                           DATE  OF PERMIT ISSUANCE--  13/03/81
PERMIT HO. (REGION FILE NO.) PSD-TX-405                                                         ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY       EPA REGION VI                  JOHN BUNYAK                          121""~~~~*"1~*"~~~""~~"

Z VACUUM DISTALL. UNITS, GAS        200.00 MMBTU/H EA
                                                           S02       0.0270 LB/MMBTU                                          NSPS
                                                                            LIMIT H2S TO 0.10 GR/DSCF
                                                           NOX       0.1200 LB/HMBTU                                          BACT
                                                                            COM. AIR CONT. BY BURN.  DESIGN


NOTES 	















                                                                                                       INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED  FOR THIS TABLE.                                 _     _ -^'T"' <--T\^-:  _^''01/19S3	

PAGE G- 320                                           ID NUMBER TX-C019                                     SOURCE TYPE CODE    5.1

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE—-         PETROLEUM REFINING - CONVERSION                                55000.00 BBL/D


COMPANY NAME/SITE LOCATION  ASHLAND OIL, INC.                                                 LEACH, KY


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE OF PERMIT ISSUANCE—  09/21/82
PERMIT HO. C-82-127 SEE NOTE                                                                   ESTIMATED DATE OF START-UP—   1983
DETERMINATION MADE BY       KENTUCKY DAPC                  BILL DILLS                          <502 )-564-3362
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
CRACKER, REDUCED CRUDE W/2 FB C*
800.00 MM3TU/H
                                                           PM       68.0000  LB/H
                                                                   298.0000  T/YR
                                                                            FABRIC FILTER
                                                           CO      300.0000  PPM
                                                                  2234.0000  T/YR
                                                                            AFTER  BURNER
                                                           S02      250.0000  PPM
                                                                  «(260.0000  T/YR
                                                                            DRY LIME  INJ.
                                                           NOX        0.2000  LB/MMBTU
                                                                   713.0000  T/YR
                                                           VOC       65.0000  T/YR
                                                                            PROCESS CHANGE
                                                                                         LAER

                                                                                         99.70
                                                                                         BACT

                                                                                         93.70
                                                                                         LAER

                                                                                         92.90
                                                                                         BACT

                                                                                         LAER
                                                                                         66.20
NOTES 	
NOTE — C-62-127 WAS NOT A NSR/PSD PERMIT.  IT MODIFIED  FACILITIES  BEING CONSTRUCTED  UNDER  PERMIT C-80-127 ISSUED 12/01/60 KHIC
H WAS BOTH NSR & PSD.
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 321
                                                                  INITIAL REVIEW  POST STARTUP
                                                     REVIEW STATUS:   04/01/19S3    02/13/1964
                                                      ID NUMBER  KY-0026
                                                                                                           SOURCE TYPE CODE
                                                                                                                               5.2

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                         05/22/1984



SOURCE TYPE/SIZE—         PETROLEUM REFINING - CONVERSION


COMPANY NAME/SITE LOCATION  CHAMPLIN PETROLEUM CO.                                      WILMINGTON, CA


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE—   03/24/80
PERMIT NO. LA-79-05                                                                            ESTIMATED DATE OF START-UP—
DETERMINATION MADE BY       EPA REGION IX                  LARRY BOWERMAN                      (415)-974-8213
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHOKE )



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... S BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT  EFF
__w« ___.-__.. _____________.._.. ________..~_~ — — _ — _.___«..____ . _ _ . . — _..»___ „ ______ __ _. ___ _«___._ _ _ — — -..,— —— — i————— — — —— ——•. —^ —— — ——-, — ___ . v ~_ ___ __

FCC UNIT                          30000.00 BBL/D
                                                           S02      84.0000 LB/H 2H AV
                                                                    56.0000 LB/H 24H AV
                                                                            SULFLf? SCAVENGING ZEOLITE CATALYST
                                                                            DESULFURIZATION OF FEED TO 0.2X S
ALKYLATION UNIT, HYDROFLUORIC A*   8500.00 BBL/D
                                                           S02     230.0000 MS/DSCM H2S
                                                                     0.1000 GR/DSCF
                                                                            SULFUR IN FUEL
CATALYTIC POLYMERIZATION UNIT      3500.00 BBL/D
                                                           S02     230.0000 MG/DSCM H2S
                                                                     0.1000 GR/DSCF
                                                                            SULFUR IN FUEL


NOTES		
0.2X S FEED. -- FLUIDIZED CATALYTIC CRACKING UNIT







                                                                                                      INITIAL REVIEW  POST STARTUP
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:  04/01^,933     C<+/04/1?S4

PAGE G- 322                                           ID NUMBER CA-0016                                    SOURCE TYPE  CCDE     5.2

-------















































cn z
0 0
ro X






0 0

O H*
w ro
I-" 0
0 0

o r- r- r-
• W 0 CO
I"J,^ ^ ij
ci :: T. C:
SB w o ro
\HX-I
ad c
CO OT
n cr
~n sj
Z
x
cn »

M m
Z x
n
n rn
C cn
m CO
r-

Q M
> XI





















7. OT
CO >
•a o
CO -4

x
rn
j>
—^
m
S3

3
X
m
0

0
M
CO

X
— <
0
XI
o
-t

m
-(
m
*




J>
O
o
o



1









CO
0
ro






o
t
o
w
ro
o

o r-
• OT
1-1 ^
o ;:
,TJ UJ
~\ -H
0 C
co
n
-n
X
CO

f-f
z

•n
C
m
r~

01
in




















7.
CO
13
cn
















































Z
o
X






o

i-f
ro
o
o

r- i—
O CO
*" ~c
Z "'
p ro

co
c
S3
Z
ft*

m
X
n
in
CO
CO

j»
M
S3





















ro
j>
o
H

X
rn
j>
-<
rn
XI

X
m
O
CO
m
Z
m
X

a
XI
o
-4
XI
m
^
H
m
XI
XI
*




ro
VI
o
o

~f
ro
^
x








CO
0







o
•
a
w
w
o

o r-
• ro
M -t
o r:
S3 CU
0 C
r/1
O
-n
x
ro
CO

M
Z

-n
C

r~

5
cn




















Z
CO
•o
cn
















































Z
o
X






o

f_<
ro
a
o

r~ r-
o 03
£ X
Z °?
p CD

CD

Z
»•

m
X
O
m
CO
CO

>^
XI





















03
J>
O


x n
m o
^, p^
-I m
m xi
XI
x
m
m -i
XI m
O XI
CO
m
Z
m
x

o
XI
o
H

m
^
-t
m
O
*



ro
ro -g
£• 09
0 O
0 O

§TJ
CP
~> ^
C C
x x
X X








CO Z
o o
ro X






o o

O M
ro c»
«o o
0 O

o r- r- r~
• TO O CO
!-> X i: X
o :? z r:
S3 ro o 5>
C3 C d
CO 03
O C
•n si
X ?
ro
cn 8»

M m
z x
0
"n m
C CO
rn cn
r*

G) M
> XI
cn




















z ro
cn >
•D o
CO -(

-H T3
o ^o
o
H O
X m
M CO
co cn
m
TI cn
m
xi cn
3 C
M ro
H (_
rn
O
H
















^
n x
> XI
TI Q
> C

M X
-H T3
-< C
-H






T3
m o
3 r"
M |—
H C
H H
m j>

H



m
3
M
cn
cn
M
O
o z

z r-
H M
S3 3
O M
r- -t
CO
rn
C
M
3
m
z
-H

0
XI

T3
S3
O
O
m
cn
CO

3
O
a
M
n
H
n
>
-i
M
O
Z

• •

• •

T3 »
n
H 03
j>
m cn
-n M
-n CO
n
n
n
n
n
n
n
H
u
n
n
n
n
ii
n
n
n
ii
i
i
n
i
i
i
i
i
i
i
i
i —
i >
1 G*>
i m
l Z
i O
i -<
i
i
i
l
i
i
l
l
l
l
r
i
1
i
l
l
l ~
i >
1 Q
i m
1 Z
i n
i -<
i
i n
1 O
l Z
1 H
1 >
i n
1 H
i
1 TJ
l m
1 S3
i cn
1 O
i Z
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i

1 TJ
1 X
1 O
1 Z
l m
1 —
1
1
1
1
1
1
1
1
1
1
1
1
1
1

1
1
1
1
1
1
1
1
1
0-00
m rn m
H XI H
m 3 m
XI M XI
3 H 3
M M
Z Z Z
> O )>
-H • -(
O -* O
Z XI Z
m
3 CT M
J» M CO
0 0
m Z CD

CO -n o
•< M -»
r-
m n

Z xi
Q

-_-
m 3
T3 TJ O
> cn a
a 1-1
X) 1 TI
rn H M
 x rn
M 1 0
O £•
z o cn
CO O
5 i
O
m












H
0
^£

0
M


C/J





















— . rn O
M O) ^"
M H H
4> M m
^* "T
l > 0
vj H H
O- m
^J O TJ
i m
M a xi
 3
*O "-^ M
•e- rn H

O M
•n cn
cn
CO C
-H >
53
-i m
i i
C 1
TJ

1 M
M
X
M
^4
X
09
M
n
o
3
T3
J>
z

r
3
m
X
cn

-l
m
r*
R

-H
M

"Z


TlS
XI 3
M TJ
< 1-
m M
XI Z
XI TJ
O m
§3
X O
cn i—
o ft
|i
rn n
XI O
Z •






























n
o
XI
1

o
X
;O
H
CO

HI
V

3














g
m
O
m
CO

n

(~
2
**i
-<
CO



o
m

H
TJ
m
X
CO
H
N
m
1
1
1








TJ
m
H
XI
O
r-
m
§

XI
m
•n
H
z
M
in
i
n


II TJ
II TJ
i m
: §
II M
II X
II
II 1
II 1
II
ii a
n m
II H
n >
II M
ii r-
ii m
i a
u
n cn
n O
" S
II XI
n n
n m
n
ii r~
II M
II tA
II H
II M
II Z
II G7
II
II
II
II
II
II
II
II
II
II
II
II
II
II
II
II
II
II
II
II
If
II
II
II
II
II
II
(1
II
II
II
II
II
II
II
II
II
II
II
II
II O
(i cn
II X
ii ro
n ro
II X
II H
II -O
n a
ii *•

-------
NOTES
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.


PAGE G- 324
                                                                                                     INITIAL REVIEW  POST STARTUP
                                                                                        REVIEW STATUS;   04/01/1933
10 NUMBER TX-OQ18
                                                     SOURCE TYPE  CCDE     5.2

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                         05/22/198*



 SOURCE TYPE/SIZE—         PETROLEUM REFINING - CONVERSION                                 6100.00 BBL/D
                           ~~ —---------- ----- — - — — -- — - — — — — — - — — — — — ---— — — — ---- — — - — — - — •-.	- —	— - — — — -.- — -_ — — ----_ — -«. — _-____.-. — _«.._«___»._

 COMPANY NAME/SITE  LOCATION  CHEVRON                                                       RICHMOND, CA
                           ~™~~™»»— —————-• — ••—*- — — •••— — — «_•. — »__ MV. __ ____ _ _______ _.__... ____ __ _____....__ __________ _____ _ _ _______ ___________ »•_

 DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE—  10/06/81
 PERMIT NO. 27803                                                                               ESTIMATED DATE OF START-UP—    1983
 DETERMINATION MADE BY       BAY AREA AQMD                  JOHN SWANSON                        «tl5)-771-6000
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



 PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... 8 BASIS
 TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF


 FCC                               61000.00 BPD
                                                           PM       10.0000 LB/H
                                                                   240.0000 LB/D
                                                                            2 PARALLEL ESP'S                                 94.00


 NOTES 	
 ESP COST $9600000. FILE A 350-009
(*> INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 325
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS;
                                                      ID  NUMBER CA-0045B
                                                                                                           SC'JSCE TYPE CCDE    5.2

-------
                                             APPENDIX --  DETAILED SOURCE  LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE---
                            PETROLEUM REFINING - CONVERSION
                                                                                              45.00 MBPSD
COMPANY NAME/SITE LOCATION  EXXON CO., USA/BAYWAY REFIN.
                            1400 PARK AVENUE
                                                                                            LINDEN, NJ  07036
                                                                                UNION COUNTY
DETERMINATION IS  B/L
PERMIT NO.
DETERMINATION MADE BY
                            EPA REGION II
                             (AGENCY)
                    • LARRY  KARAS
                  (AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE—  10/27/80
                                       ESTIMATED DATE OF START-UP--
                                       (212)-264-953S
                                           (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
...  t  BASIS
...  PCT  EFF
PROCESS HEATER
HYDROFINER POWER FORMER
TASK AGE
FUGITIVE EMISSIONS
                    VOC        5.1000  T/YR                                              LAER
                                      02  ANALYZER/EFFICIENT  COMBUSTION
                    NOX     1663.0000  T/YR                                              BACT
                                      CONVENTIONAL  BURNERS
                    S02      195.4000  T/YR                                              BACT
                                      SCRUBBER  &  SULFUR  PLANT
                                      .1  GR/DSCF  H2S-FLUEGAS/.5X S  BY WT.  FUEL  OIL

                    VOC        2.5000  T/YR                                              LAER
                                      FURNACE BURNER
                    S02     4416.6000  T/YR                                              BACT
                                      3 CLAUS & 1 PARSON BEAVON UNITS

                    VOC        4.1000  T/YR                                              LAER
                                      EXT.  FLOATING ROOF + DOUBLE SEAL
                                      EXT.  FLOAT. ROOF t 2 SEALS

                    VOC      203.0000  T/YR                                              LAER
                                      PROPER COflBUSTION
                                      PROPER MAINTENANCE
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PA3E G- 326
                ID  NUMBER NJ-0001
                                                                INITIAL REVIEW   POST  STARTUP
                                                   REVIEW  STATUS;   04/01/1933
                                                                    SOURCE TYPE CODE    5.2

-------
NOTES 	
A NEW 45 MB/SD CATALYTIC REFORMING UNIT (POWER FORMER) WILL UPGRADE OCTANE LEVELS OF VIRGIN AND ICN NAPHTHAS.
                                                                                                     INITIAL REVIEW  POST STARTUP
(») INDICATES DATUM WAS TRUNCATED FOR  THIS TABLE.                                        REVIEW STATUS:  0^/01/1933
PAGE G- 327                                          ID NUMBER NJ-0001                                    SOURCE TYPE CODE    5.Z

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/28/1984



SOURCE TYPE/SIZE—         PETROLEUM REFINING - CONVERSION                                 1480.00 BPSD


COMPANY NAME/SITE LOCATION  TEXAS OLEFINS CO.                                                     , TX
                                                                                                                     HARRIS COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERnlT ISSUANCE-  11/23/83
PERMIT NO. 9348                                                                                ESTIMATED DATE OF START-UP—   19S4
DETERMINATION MADE BY       TEXAS ACB          .           KAREN NEUMANN                       (BIZ 1-451-5711
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ...  j BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT  OR  PROCESS MODIFICATION  . ..'  PCT EFF
	

POLYMERIZATION UNIT                14SO.OO BPSD
                                                           VOC       54.8200  T/YR                                              BACT
                                                                            SEE NOTES
                                                           NOX        8.4700  T/YR                                              BACT
                                                                            LOW NOX BURNERS
                                                           CO         1.2600  T/YR                                              BACT
                                                           PM         0.3500  T/YR


NOTES 	
SIC = 2869.  VOC CONTROL PROVIDED BY VAPOR  RECOVERY UNIT  ON  TOAOINS OPERATIONS/  DIRECTED MAINTENANCE CH VALVES, PUMPS, ETC /  FL
ARES FOR UPSET EMISSIONS/ FLOATING ROOFS WITH SECONDARY  SEALS ON TANKS.
(») INDICATES DATUM WAS TRUNCATED FOR  THIS  TABLE.

PAGE G- 328
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS;  05/04/1934
                                                     ID NUMBER TX-0140
                                                                                                          SOURCE TYPE CODE
                                                                                                                              5.2

-------
                                             APPENDIX  —-  DETAILED  SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE—-         PETROLEUM REFINING -  CONVERSION                                20000.00 MBBL/D


COMPANY NAME/SITE LOCATION  UNITED REFINING CO.                                              WARREN, PA
                                                                                                                     HARREN COUNTY


DETERMINATION IS  B/L FOR A MODIFIED SOURCE.                                                    DATE OF PERMIT ISSUANCE—  01/25/80
PERMIT NO. 78PA14                                                                              ESTIMATED DATE OF START-UP—   1980
DETERMINATION MADE BY       EPA REGION III                  VERNON  BUTLER                       (215J-597-2711
                             (AGENCY)                   (AGENCY  CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT         POLLUTANT     EMISSION LIMITS                                   ...» BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF


FCC UNIT
                                                           S02      350.0000 LB/H                                             BACT
                                                                            0.652 S FUEL OIL
REFORMER HEATER
                                                           S02       65.0000 LB/H                                             BACT
                                                                            IX S IN FUEL OIL
CLAUS PLANT
                                                           S02                                                                BACT
REBOILER
                                                           S02       24.0000 LB/H                                             NSPS
                                                                            17. S FUEL OIL


NOTES 	
S02 EMISSIONS FROM FLUID CATALYTIC CRACKER  UNIT,  REFORMER HEATER,  AND REBOILER IMPACT ON NON-ATTAINMENT AREA








                                                                                                      INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS  TABLE.                                         KL.Ii.ii STATUS:  CVQ1/19S3

PAGE G- 329                 '                          ID  N'JTIBLR  PA-CG16                                    Sw-'-CE TrPE CODE    5.2

-------
                                             APPENDIX  ~ DETAILED SOURCE  LISTING
                                                                                                                        05/82/198*




SOURCE TYPE/SIZE—-         PETROLEUM REFINING -  TREATING


COMPANY NAME/SITE LOCATION  ENDEVCO, INC.                                                     FOUKE,  AR               „,. , „ „„,„.,,-„
                            ST. HWY 134                                                                              MILLER COUNTY
                           	;	

DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE  OF PERMIT ISSUANCE-  13/03/S1
PERMIT NO. AR-240M-1                                                                           ESTIMATED DATE OF START-UP-   I960
DETERMINATION MADE BY       EPA REGION VI                   TOM  DIGGS                            < 214 J-767-1594
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT         POLLUTANT     EMISSION LIMITS                                   ...» BASIS
TO THIS PERMIT                         CAPACITY         EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ...  PCT EFF
		

DIETHANOLAMINE RECONCENTRATOR     60000.00 BTU/H
                                                           S02        0.1000 LB/H                                              BACT
                                                                            FIRINS OF NAT GAS
TRIETHYLENE GLYCOL                60000.00 BTU/H
                                                           S02        0.1000 LB/H                                              BACT
                                                                            FIRING OF NAT. GAS
INCIN.                                                                                                                       _.__
                                                           S02      460.0000 LB/H                                              BACT
                                                                            NO CONTROL,USED TO CONTROL H2S



NOTES 	











                                                                                                      INITIAL REVIEW  POST STARTUP
<*> INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS;__°_4/01/19S3	

PAGE~G-~330"ID NUMBER AR-0003                                    SOURCE TYPE CODE    5.3

-------
                                             APPENDIX — DETAILED  SOURCE LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE---
                            PETROLEUM REFINING - TREATING
                                                                                               2.00 MMSCFD
COMPANY NAME/SITE LOCATION  OIL INTERNATIONAL LTD
                                                                                           OILMONT,  MT
                                                                                                                      TOOLE COUNTY
DETERMINATION IS
PERMIT NO.
DETERMINATION MADE BY
                            STATE OF MONTANA
                             (AGENCY)
   HARRY KELTZ
(AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE--  03/10/83
                                       ESTIMATED DATE OF START-UP—
                                                                                                   ( PHONE )
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
CAPACITY
POLLUTANT
EMITTED
EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION
... & BASIS
... PCT EFF
INCINERATOR
                                      2.00 MMSCFD
                                                           S02       57.0000  LB/H
                                                                   2*9.0000  T/YR
                                                                            INCINERATION
                                                                     BACT

                                                                      0.00
NOTES 	
50 WEEK/YR OPERATION - PLANT IS IN BASICALLY  SAME  LOCATION  AS  OLD  PERMIT
<*) INDICATES DATUM WAS TRUNCATED FOR  THIS TABLE.

PAGE G- 331
                                              INITIAL REVIEW  POST STARTUP
                                 REVIEW STATUS:   04/01/1933
                                                     ID NUMBER MT-0003
                                                                                                           SOURCE  TYPE  CODE     5.3

-------
                                             APPENDIX  ~  DETAILED  SOURCE  LISTING
                                                                                                                        05/22/1984
z = rzr = = — — z — ~zrr = z = ~~cz —	— — — — — — __—«_—	—	— — —	— — —	—	— — — — — —	— - — —	— — —            —


SOURCE TYPE/SIZE — -         PETROLEUM REFINING - TREATING
                           	

COMPANY NAME/SITE LOCATION  PACIFIC REFINING CORP.                                         HERCULES,  CA


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                  DATE  OF  PERMIT ISSUANCE—  09/38/63
PERMIT NO. 29180                                                                               ESTIMATED  DATE OF START-UP—   1986
DETERMINATION MADE BY       BAY AREA AQMD                  LEONARD CLAYTON                     (415)-771-6000
                             (AGENCY)                   (AGENCY  CONTACT PERSON)                    ( FHCNE )



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION LIMITS                                   ...  t BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT  OR  PROCESS  MODIFICAT^4  ...  PCT EFF
	

FUEL HANDLING, REFINERY FUEL GA* 500000.00 SCF/H
                                                           S02       50.0000 PPM H2S IN FUEL  GAS                               BACT
                                                                            DIGLYCOL AMINE SCRUB  SYSTEM                      80.00
FURNACE, REFORMING                  275.00 MT1BTU/H
                                                           NOX       20.0000 PPM AT 3X 02                                     BACT
                                                                            SCR & NH3 INJECTION                               85.00


NOTES 	
SCR = SELECTIVE CATALYTIC REDUCTION














                                                                                                      INITIAL REVIEW  POST STARTUP
(*) IS-OICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW  STATUS:  04/19/1934

PAGE G- 332                                           ID NUMBER  CA-0056                                    SOURCE TYPE CCDE    5.3

-------
                                             APPENDIX ~ DETAILED SOURCE LISTING
                                                                                                                       05/22/1984



SOURCE TYPE/SIZE—         PETROLEUM REFINING - TREATING                                      5.00 HP


COMPANY NAME/SITE LOCATION  TOSCO CORP.                                                   MARTINEZ, CA


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—  02/19/82
PERMIT NO. 27769                                                                              ESTIMATED DATE OF START-UP—   1983
DETERMINATION MADE BY       BAY AREA AQMD                  JIM KARAS                           1415 J-771-6COO
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... t BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... FCT EFF


CENTRIFUGAL PUMPS                     5.00  HP
                                                          VOC     500.0000 PPM
                                                                           DOUBLE MECH. SEAL W/HEAVY SEAL OIL


NOTES 	
(*) INDICATES DATUM WAS TRUNCATED  FOR  THIS TABLE.

PAGE G- 333
                                                     ID NUMBER CA-0046
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS;  0^/01/1933
                  SOURCE TYPE C02E    5.3

-------
                                             APPENDIX  — DETAILED  SOURCE LISTING
                                                                                                                         05/2 2/1984



SOURCE TYPE/SIZE—-          PETROLEUM  REFINING  - FEEDSTOCK                                     10.80 MMGAL


COMPANY NAME/SITE LOCATION   AMOCO  OIL  CO.                                                   WHITING, IN
                           —	— — — — — —	— — —	__.»	— „ —.	— — — — — — — — — — — — — — — — — — — — — —— — — — —— — —— — — — — —— — — ___ — _____»_______ —__,._.,_._,_„_._.._,_._,._._,_.._._._,_

DETERMINATION IS LAER FOR A  NEW SOURCE.                                                         DATE OF PERMIT ISSUANCE—  02/27/81
PERMIT NO. PC (45) 1479                                                                         ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY        INDIANA APCD                   KEN KEARNEY                          (317)-633-0647
                             (AGENCY)                   (AGENCY CONTACT  PERSON)                     (PHONE)

=========r=:=r===============r===r==================r=====r===r===r==============r====r====r=r============r====r===r==============

PROCESSES SUBJECT                      THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    . .. fc BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF


STORAGE TANKS, GASOLINE                5.40 HKGAL
                                                           VOC                                                                LAER
                                                                            WELDED TANKS & INT FLOAT ROOFS


NOTES 	
2 GASOLINE STORAGE TANKS
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 334
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS:  04/01/19S3
                                                      ID NUMBER IN-0010
                                                                                                            SOURCE  TYPE  CCDE    5.4

-------
                                             APPENDIX  — DETAILED  SOURCE  LISTING
                                                                                                                        05/22/198*
SOURCE TYPE/SIZE	
                            PETROLEUM REFINING  -  FEEDSTOCK
COMPANY NAME/SITE LOCATION  ARCO PIPELINE CO.
                            FT. MIFFLIN TERMINAL
                                              TINICUM TOWNSHIP, PA
                                                                                                                   DELAWARE COUNTY
DETERMINATION IS BACT FOR A MODIFIED SOURCE.
PERMIT NO. 79PA24
DETERMINATION MADE BY       EPA REGION III
                             (AGENCY)
                       BOB BUSZCZAK
                    (AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE—  01/18/80
                                       ESTIMATED DATE OF START-UP—   1981
                                       (£15)-597-8186
                                           (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
  THROUGHPUT
   CAPACITY
POLLUTANT    EMISSION LIMITS                                   ... $ BASIS
 EMITTED            CONTROL EtJUIPMENT OR PROCESS MODIFICATION  . . . FCT EFF
STORAGE TANKS NO. 1
STORAGE TANKS NOS. 2, 13, 15
STORAGE TANKS NOS. 4, 12
STORAGE TANKS NOS. 9, 10
STORAGE TANKS NOS. 11, 14
 10.00 MBBL


100.00 MBBL


150.00 MBBL


100.00 MBBL


100.00 MBBL
   VOC       0.2700 LB/H
                    INTERNAL FLOATING ROOFS

   VOC       1.6500 LB/H
                    INTERNAL FLOATING ROOFS

   VOC       2.1600 LB/H
                    INTERNAL FLOATING ROOFS

   VOC       1.3200 LB/H
                    INTERNAL FLOATING ROOFS

   VOC       1.6100 LB/H
                    INTERNAL FLOATING RCOFS
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
NOTES
(*) INDICATES DATUM WAS TRUNCATED FOR  THIS TABLE.

PAGE G- 335
                                                                  INITIAL REVIEW  POST STARTUP
                                                     REVIEW STATUS:   04/01/1933
                                                     ID NUMBER PA-0010
                                                                                                           SOURCE  TYPE  CODE    5.4

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE—
                            PETROLEUM REFINING - FEEDSTOCK
COMPANY NAME/SITE LOCATION  VENTECH REFIN.
                            JCT. HWY 190 * RT. 105
                                                    KROTZ SPRINGS,  LA 70750
                                                                                                                 ST. LAN-DRY PARISH
DETERMINATION IS BACT FOR A MODIFIED SOURCE.
PERMIT NO. (REGION FILE NO.) PSD-LA-278A
DETERMINATION MADE BY       EPA REGION VI
                             (AGENCY)
                          TOM DIGGS
                       (AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE—  03/13/80
                                       ESTIMATED DATE OF START-UP—
                                       (214>-767-159<+
                                           (PHOKE)
PROCESSES SUBJECT
TO THIS PERMIT
     THROUGHPUT
      CAPACITY
POLLUTANT    EMISSION LIMITS                                   ... « BASIS
 EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
TANKS, 2EA


TANKS, 6EA


TANK


BARGE LOAD/UNLOAD
120000.00 BBL
 55000.00 BBL
 25000.00 BBL
   VCC       0.8700 LB/H
                    DOUBLE SEALS

   VOC       0.0200 LB/H
                    DOUBLE SEALS

   VOC       0.3500 LB/H
                    DOUBLE SEALS

   VOC       3.0200 L8/H
                    VAPOR COLLECTION k INCIN. SYS
                                                                                            BACT
                                                                                            BACT
                                                                                            BACT
                                                                                                                             BACT
NOTES
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 336
                                                                    INITIAL REVIEW  POST STARTUP
                                                       REVIEW STATUS:  04/01/1?S3
                                                     ID NUMBER  LA-0026
                                                                                                           SC'J~CE  TYPE  CODE     5.4

-------
                                             APPENDIX —  DETAILED  SOURCE  LISTING
                                                                                                                        05/32/1984
SOURCE TYPE/SIZE—
                            PETROLEUM REFINING -  AUXILIARY
COMPANY NAME/SITE LOCATION  ALLIED MATERIALS CORP.
                            RT. 66
                                                      STROUD, OK
                                                                                                                    LINCOLN COUNTY
DETERMINATION IS BACT FOR A MODIFIED SOURCE.
PERMIT NO. (REGION FILE NO.) PSO-OK-344
DETERMINATION MADE BY       EPA REGION VI
                             (AGENCY)
                     BILL TAYLOR
                  (AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE—  09/30/81
                                       ESTIMATED DATE OF START-UP—   1931
                                       (ai4)-767-1594
                                           (FHOK'E)
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT    EMISSION LIMITS                                    ... * BASIS
 EMITTED            CONTROL EQUIPMENT OP PROCESS MODIFICATION   ... PCT EFF
WASTE INCINERATOR/HEAT RECOVERY*
                                     56.00 MM3TU/H
                                                           S02
                                                                     4.4300 LB/MMBTU
                                                                            NONE APPLICABLE
                                                                                       BACT
NOTES 	
WASTE INCIN./HEAT RECOVERY UNIT.
(*> INDICATES DATUM WAS TRUNCATED  FOR  THIS  TABLE.

PAGE G- 337
                                                                INITIAL REVIEW  POST STARTUP
                                                   REVIEW STATUS:   04/01/1983
                                                     ID NUMBER OK-0007
                                                                                                           SOURCE TYPE CODE    5.5

-------
                                              APPENDIX — DETAILED SOURCE LISTING
                                                                                                                          05/23/1984



SOURCE TYPE/SIZE	          PETROLEUM REFINING -  AUXILIARY
                            "• — — — — — — — — — — _—. — — _ — — _ — .-____.,_____ «.,__ — _ _«_._....._.. __ ___ __. ™«.___ ___.. _«_ ... __-.__..__.__.._— ».^_™.«»_..«_ — _ ___ » — — .. __.

COMPANY NAME/SITE  LOCATION  AMERICAN PETROFINA CO.  OF TEXAS                                       , TX
                                                                                                                    JEFFERSON COUNTY


DETERMINATION IS BACT  FOR  A MODIFIED SOURCE.                                                    DATE OF PERMIT ISSUANCE—  01/21/83
PERMIT NO. SEE NOTE                                                                             ESTIMATED DATE OF  START-UP—   1964
DETERMINATION MADE BY        TEXAS ACS                      STUART KEIL                         (512 )-451-5711
                              fAGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                      THROUGHPUT         POLLUTANT    EMISSION LIMITS                                    ...» BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ...  PCT EFF
""" — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —— — -.— — — — —	— — — — — — — — — «.«.-. — _•. — _ — — _-,_ — -.__ —— __^_ __„ — _„ _______ _..-._.»,».___.»_„___..___.._.._____

COMBUSTION UNITS
                                                           NOX        0.1200 LB/MMSTU GAS
                                                                      0.3000 LB/MSAL LIQUID
                                                                             STAGED COMBUSTION
NEW & EXISTING SRU'S
                                                           S02     250.0000 PFM                                               NSPS
                                                                             SCOT TAIL GAS CLEAN-UP
                                                           H2S               NOTE «2
                                                                             FUG. MONITOR & MAINTEN.  FOR H2S PROCESS LEAKS


NOTES 	
NOTE -- PERMIT NO. C-9193,9194,9195,9196

NOTE 82 — MININIZE FUGITIVES








                                                                                                       INITIAL REVIEW   POST  STARTUP
(*) INDICATES DATUM WAS TRUHCATED  FOR  THIS  TABLE.                                         Kcvit_,< SIAVUS:   05/0-»,'19o4

PAGE G- 333                                           ID NUMBER  TX-0127                                    SOURCE TYPE CODE     5.5

-------
                                            APPENDIX  — DETAILED SOURCE  LISTING
                                                                                                                        05/22/1934
SOURCE TYPE/SIZE — -
                            PETROLEUM REFINING  - AUXILIARY
                                                                                             130.00 MBPSD
COMPANY NAME/SITE LOCATION  AMOCO
                            5TH AVE.  S.  TEXAS CITY
                                TEXAS CITY, TX
                                                                                                                  GALVESTON  COUNTY
DETERMINATION IS BACT FOR A MODIFIED SOURCE.
FESMIT NO. (REGION FILE NO.) FSD-TX-402
DETERMINATION MADE BY       EPA REGION VI
                             (AGENCY)
   JOHN BUNYAK
(AGENCY CONTACT PERSON)
DATE OF PERMIT ISSUANCE—  12/08/81
ESTIMATED DATE OF START-UP—
(214J-767-1594
    (PHONE)
PROCESSES SUBJECT THROUGHPUT POLLUTANT EMISSION LIMITS ... & BASIS
TO THIS PERMIT CAPACITY EMITTED CONTROL EQUIPMENT OR PROCESS MODIFICATION ... PCT EFF
HEATERS, 12 EA 144.00 MMBTU/H
NOX

S02

SULFUR RECOVERY UNIT 1000.00 LT/0 SULFUR
NOX

so a

SRU FLARE 8.80 MMBTU/H
NOX

SOC

HYDROTREATER FLARES, 2 6.10 MMBTU/H EA
NOX

SOS

0.1200

0.0300


13.0000

250.0000


0.1200

0.0300


0.1200

0.0300

LB/MMBTU
LOW NOX BURNERS
LB/MM3TU
GAS FIRED

LB/H
EFFICIENT OPERATION
PFM
3-STAGE CLAUS UNIT

LB/MMBTU
EFFICIENT OPERATION
LB/MM3TU
GAS FIRED

LB/KM3TU
EFFICIENT OPERATION
LB/MJ1STU

BACT

NSPS


BACT

NSPS
99.90

BACT

NSPS


BACT

BACT
                                                                           GAS FIRED
(*) INDICATES DATUM WAS TRUNCATED  FOR  THIS TABLE.

PAGE G- 339
                                              INITIAL REVIEW  POST STARTUP
                                 REVIEU STATUS;   04/01/1933
                                                     ID NUMBER TX-0020
                                                                                                          SOURCE TYPE CC3E    5.5

-------
NOTES 	
H2S LIMITED TO 0.1 GRAIN/DSCF.
                                                                                                      INITIAL PEVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEW STATUS:   C-t/ 01/"i9S3

PAGE 6- 340                                           ID  NUMBER  TX-OOeO                                    SGU"CE TtFE CC3E    5.5

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/198*
SOURCE TYPE/SIZE	
                            PETROLEUM REFINING - AUXILIARY
                                                                                           50000.00 BPSD
COMPANY NAME/SITE LOCATION  AMOCO TEXAS REFINING CO.
                            2401 5TH AVENUE SOUTH
                                                  TEXAS CITY, TX 77490
DETERMINATION IS BACT FOR A MODIFIED SOURCE.
PERMIT NO. TX-101
DETERMINATION MADE BY       EPA REGION VI
                             (AGENCY)
                     JOHN BUNYAK .
                  (AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE--
                                       fSTIflATEO DATE OF START-UP-
                                       <214>-767-1594
                                           ( PHCME )
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT    EMISSION LIMITS
 EMITTED            CONTROL EQUIPMENT 03 PROCESS MODIFICATION
...  &  BASIS
. ..  PCT  EFF
FURNACE, EXISTING PREHEAT
FURNACE, EXISTING REHEAT
FURNACE, EXISTING REHEAT
FURNACE, EXISTING HOT OIL
FURNACE, NEW DESULFURIZING
                     NOX      56.2000 LB/H
                                      LOU NOX/HIGH COMBUST EFF BURN

                     NOX      63.2000 LB/H
                                      LOW NOX/HIGH COMBUST EFF BURN

                     NOX      76.5000 LB/H
                                      LOW NOX/HIGH COI18UST EFF BURN

                     NOX      47.9000 LB/H
                                      LOW NOX/HIGH COMBUST EFF BURN

                     NOX      21.2000 LB/H
                                      LC-i NOX/HIGH COr-JF.UST EFF 8L'.7M
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             EACT
                                                                                                                             BACT
NOTES 	
MODIFIED GASOLINE REFORMER TO PRODUCE GASOLINE OF LOU LEAD CONTENT.  INCREASED REFORMER CHARGE RATE FPOM 49000 TO 5COOO ERL/STS
EAM DAY.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 341
                                                                INITIAL REVIEW  POST STARTUP
                                                   REVIEW STATUS:  04/C1/1<=33
                                                      ID  NUMBER TX-0067
                                                                                                           SOURCE TYPE CODE    5.5

-------
                                             APPENDIX  —  DETAILED  SOURCE  LISTING
                                                                                                                        05/22/1934



SOURCE TYPE/SIZE—         PETROLEUM REFINING - AUXILIARY


COMPANY NAME/SITE LOCATION  CALCASIEU REFIN.                                           LAKE  CHARLES,  LA
                                                                                                                   CAUSIEU PARISH


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE  OF PERMIT ISSUANCE—  07/23/81
PERMIT NO. (REGION FILE NO.) P5D-LA-293                                                        ESTIMATED  DATE OF  START-UP-
DETERMINATION MADE BY       EPA REGION VI                  JOHN  BUNYAK     -                     (214 )-767-1594
                             (AGENCY)                  (AGENCY  CONTACT PERSON)                     (FHONE)



PROCESSES SUBJECT                     THROUGHPUT       POLLUTANT     EMISSION  LIMITS                                    ...  * BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT  OR  PROCESS  MODIFICATION   ...  PCT EFF


HEATERS, 3 EA                       160.00 MMBTU/H
                                                           NOX        0.1100  LB/KMBTU                                          BACT
                                                                            LOW  NOX BURNERS                                  35.00
INCIN.                                2.00 MMBTU/H
                                                           NOX        0.1000  LB/MMBTU                                          BACT
                                                                            LOW  NOX BURNERS                                  35.00


NOTES 	
THREE HEATERS AND ONE INCINERATOR













                                                                                                      INITIAL REVIEW  POST  STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:   04/C1/1S83

PAGE G- 342                                           ID  NUMBER  LA-0019                                     SOURCE TYPE CODE    5.5

-------
                                            APPENDIX —- DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE—         PETROLEUM  REFININS - AUXILIARY                                 30000.00 BPSD


COMPANY NAME/SITE LOCATION  CAROLINA REFINING & DIST                                      SAVANNAH, GA
                            STATE  HWY  21                                                                             CHATHAM COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                         DATE CF  PERMIT  ISSUANCE—  09/10/80
PERMIT NO. GA 063                                                                              ESTIMATED  DATE  OF  START-UP—   1981
DETERMINATION MADE BY       GEORGIA EPD                    BILL MITCHELL                        (404 )-656-6
-------
                                             APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                       05/22/1984



SOURCE TYPE/SIZE—         PETROLEUM REFINING  -  AUXILIARY


COMPANY NAME/SITE LOCATION  CHAMPLIN PETROLEUM  CO.                                         HOUSTON, TX  77002
                            1200 SMITH ST.,  SUITE 1900                                                               NUECES COUNTY


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF  PERMIT ISSUANCE--   04/03/81
PERMIT NO.  TX-337                                                                             ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY       EPA REGION VI                  JOHN BUNYAK                         (214)-767-1594
                             (AGENCY)                  (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                    ... t BASIS
TO THIS PERMIT                         CAPACITY         EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF
PLATFORM CHARGE HEATERS,  3
                                    392.00  MMBTU/H
HEATER, PLATFORMER DEPENTANIZER
                                     25.20  MMBTU/H
502       9.9000 LB/H REFIN. GAS
          0.0250 LB/MMSTU REFIN. GAS
                 TRACE H2S
NOX      47.0000 LB/H REFIN. GAS
          0.1200 LB/MMSTU REFIN. GAS
                 AFR CONTROL, LNB
S02     112.7000 LB/H G/0
          0.7600 LB/NMBTU G/0
                 TRACE H2S
NOX      67.3000 LB/H G/0
          0.1700 LB/MMBTU G/0
                 AFR CONTROLS, LNB

S02       0.6000 LB/H REFIN. GAS
          0.0250 LB/MH3TU REFIN. GAS
                 TRACE H2S
NOX       3.0000 LB/H REFIN. GAS
          0.1200 LB/M"3TU REFIN. GAS
S02      17.5000 LB/H G/0
          0.7600 LB/MMDTU G/0
                 TRACE H2S
                                                                                                                            NSPS
                                                                                                                            BACT
                                                                                                                            NSPS
                                                                                                                            BACT
                                                                                                                            NSFS
                                                                                                                            NSPS
PAGE G- 344

-------
                                                          NOX        4.4000  LB/H  6/0                                          BACT
                                                                     0.1700  LB/MMBTU  G/0
                                                                            APR CONTROLS,  LNB
PAGE G- 345

-------
(CONTINUED) CHAMPLIN PETROLEUM CO.
PROCESSES SUBJECT
TO THIS PERMIT
HEATER, PLATFORM AROMATIC












HEATER, HYDROTREATER CHARGE












REBOILER, HYDPOTREATER STRIPPER











THROUGHPUT POLLUTANT
CAPACITY EMITTED
£0.30 MMBTU/H
502


NOX


502


NOX


47.60 MMBTU/H
502


NOX


502


NOX


31.40 MMBTU/H
S02


NOX


S02


NOX

EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

0.5000 LB/H REFIN. 6AS
0.0250 LB/MMBTU REFIN. GAS
TRACE H2S
2.4000 LB/H REFIN. GAS
0.1200 LB/MM3TU REFIN. GAS
APR CONTROL, LNB
13.8000 LB/H G/0
0.7600 LB/MM3TU G/0
TRACE H2S
3.5000 LB/H G/0
0.1700 LB/KMBTU G/0
AFR CONTROL, LNB

1.2000 LB/H REFIN. GAS
0.0250 LB/MM3TU REFIN. GAS
TRACE H2S
5.7000 LB/H REFIN. GAS
0.1200 LB/Ml'.BTU REFIN. SAS
AFR CONTROL, LN3
33.0000 LB/H G/0
0.7600 LB/MMBTU G/0
TRACE H2S
8.2000 LB/H G/0
0.1700 LB/MM3TU G/0
AFR CONTROL, LKB

0.8000 LB/H REFIN. GAS
0.0250 LB/MM3TU REFIN. GAS
TRACE H2S
3.8000 LB/H REFIN. GAS
0.1200 LB/r."STU REFIN. GAS
AFR CONTROLS, LKB
2.2000 LB/H G/0
0.7600 LB/MM3TU G/0
TRACE H2S
5.4000 LB/H G/0
0.1700 LB/MMBTU G/0
... t BASIS
... PCT EFF

NSPS


BACT


NSPS


BACT



NSPS


BACT


NSPS


BACT



NSPS


BACT


NSPS


BACT

PAGE G- 346

-------
                                                                            AFR  CONTROLS,  LNB
PAGE 6- 347

-------
(CONTINUED) CHAMPLIN PETROLEUM CO.
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
4 BASIS
FCT EFF
BOILERS, 3 (FUEL GAS ONLY)
                                     47.00 MMBTU/H  EA
EMERGENCY FLARE
                                     16.00 SCFM
                     S02       1.2000 LB/H
                               0.0250 LB/MMBTU
                                      TRACE H2S
                     NOX       5.6000 LB/H
                               0.1200 LB/MMBTU
                                      AFR CONTROL,  LNB

                     S02       0.1000 LB/H
                                      NOME
                     NOX       0.1000 LB/H
                                      STEAM INJECTION
                                                                     NSPS


                                                                     BACT



                                                                     BACT

                                                                     BACT
NOTES 	
FUEL OIL S CONTENT NOT SPECIFIED. PERMITTIE IS REQUIRED  TO  SAMPLE  &  ANALYZE  S CONTENT OF  FUEL  OIL  AT  LEAST ON'CE/DAY TO DETERMI
NE COMPLIANCE WITH THE ALLOWABLE S02 EMISSION LIMITS.  EMERGENCY  FLARE  OPERATED ONLY  UNDER EMERGENCY CONDITIONS.
WHEN PROCESS GASES APE VENTED TO FLARE FOR MORE THAN 5 MIN.  IN ANY 2 HOUR  PERIOD,  RECORDS SHALL  BE KEPT  FCR 2  YEARS FOLLCWINS
SUCH CCCURANCE.  TRACE = <0.10 GR/DSCF. LNS = LOW KOX BURNERS. AFR  CONTROLS =AIR/FUEL RATIO CONTROLS.  G/0 = GAS/OIL MIX.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 348
                                                                                                      INITIAL  REVIEW   POST  STARTUP
                                                                                        REVIEW STATUS:   C<+/01/1
-------
                                             APPENDIX — DETAILED SOURCE LISTING
 =======================- —	                                                       05/Z2/1984



 SOURCE TYPE/SIZE—         PETROLEUM REFINING - AUXILIARY                                  7000.00 GPCD


 COMPANY NAME/SITE  LOCATION  CHEVRON USA REF.                                            BASCAGOULA, MS
                                                                                                                    JACKSON COUNTY
                            "                                    „, — — — — ___,._ —_____„__ _ __. .»___,_»___.,_ — ___.„._ — _ __.». _ — _—_»_ — —___ __».   _   _


                                                                                               °ATE °F PERMIT I«W«1«-  «/"/80
 DETERMINATION MADE BY       MISSISSIPPI DK>,                DWIGHT WILEY                        fSJES-SSS °? ^P^P"
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)

                                     -- = = = =r = r = r=r= = = r=rr = = ==== = r = r = = r = = r== = = = = = r = r = = = = = = = = = ==r::: = = = ==r = = :: = = r = = =:: = = = = = = :;: = = = = = = ===- =

 TOTHpFT                        THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ...» BASIS
 ^THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF


 PROCESS EQUIPMENT                 16000.00 GPCD
                                                           S02       0.1000 GR/DSCF                                          NSPS
                                                                            BEAVON S REM. PROC. TAIL GAS
                                                                            LOW SULFUR
                                                           NOX     135.0000 PPM GAS                                          BACT
                                                                            DESIGN


NOTES 	

















                                                                  	             REVIEW sTATusHSSiH"If  P°ST STARTUP

                                                               MS-0007                                     ~~~~~~~~~~

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                         •05/22/1984



SOURCE TYPE/SIZE-—         PETROLEUM REFINING - AUXILIARY
                           ________« __.-.___—__ — — — _ ____•__ ______ __ _«___i_ __ — _»• — __ — — — •..— •.»-.—..— — — —..» — — -.-» — — — •» — __ — — _ — — — _ — — _ — — _..__-____,____ — .- —

COMPANY NAME/SITE LOCATION  CHEVRON USA, INC.                                             RICHMOND, CA


DETERMINATION IS BACT FOR A NEW SOURCE.                                                         DATE OF PERMIT ISSUANCE--  04/08/83
PERMIT NO. 27797                                                                                ESTIMATED DATE OF START-UP--   1984
DETERMINATION MADE BY       BAY AREA AqMD                  JOHN SWANSON                         (415J-771-6000
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (FHCNE )



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    . . .  S BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ...  PCT EFF
FURNACE 4


FURNACE 85


FURNACE 86


FURNACE 81


FURNACE 82


FUPNACE 83
57.00 MMBTU/H


18.00 MM3TU/H


15.00 MMBTU/H


12.50 MMBTU/H


19.00 MMBTU/H


66.50 MMBTU/H
NOX      40.0000 PPM K02
                 ONE SCR

NOX      40.0000 PPM N02
                 ONE SCR

NOX      40.0000 PPM N02
                 ONE SCR

NOX      40.0000 PPM N02
                 ONE SCR

NOX      40.0000 PPM N02
                 CNE SCR

NOX      40.0000 PPM K02
                 CNE SCR
AT 37. 02
UNIT ON FURNACES 4,5,6

AT 37. 02
UNIT ON FURNACES 4,5,6

AT 37. 02
UNIT ON FURNACES 4,5,6

AT 37. 02
UNIT ON FURNACES 1,2,3

AT 37. 02
UNIT ON FURNACES 1,2,3

AT 37. 02
UNIT ON FURNACES 1,2,3
PAGE G- 350

-------
 (CONTINUED) CHEVRON USA, INC.
PROCESSES SUBJECT
TO THIS PERMIT
FURNACE »7


FURNACE «8


FURNACE 89


FURNACE S10

KinTP1; 	
THROUGHPUT POLLUTANT EMISSION LIMITS ... 4 BASIS
CAPACITY EMITTED CONTROL EQUIPMENT OR PROCESS MCDIFICATICN ... PCT EFF
22.00 MMBTU/H
NOX 40.0000 PPM
ONE
28.00 MMBTU/H
NOX 40.0000 PPM
ONE
26.00 MMBTU/H
NOX 40.0000 PPM
ONE
15.00 MMBTU/H
NOX 40.0000 PPM
ONE

N02
SCR

N02
SCR

NO 2
SCR

NO 2
SCR

AT "*,•/. 02
UNIT ON FURN.

AT 3* 02
UNIT ON FURN.

AT 37. 02
UNIT ON FURN.

AT 37. 02
UNIT ON FURN.


7,8,9,10


7,8,9,10


7,8,9,10


7,8,9,10
SCR = SELECTIVE CATALYTIC REDUCTION, FURNACES ARE BURNING REFINERY MAKE GAS OF  1025 BTU/ACF
(*) INDICATES DATUM WAS TRUNCATED  FOR THIS TABLE.


PAGE G- 351
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS;  04/01/1933
                                                     ID NUMBER CA-0045
                                                                                                          SOURCE TYPE CODE    5.5

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE-—         PETROLEUM REFINING - AUXILIARY


COMPANY NAME/SITE LOCATION  CITIES SERVICE CO.          ,                              LAKE CHARLES, LA 70602
                            P.O. BOX 1562


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE—  01/18/80
PERMIT HO.                                                                                     ESTIMATED DATE OF START-UP--
DETERMINATION MADE BY       EPA REGION VI                  JOHN BUNYAK                         (214)~767-1594
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... 4 BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ... PCT EFF
REFORMER FURNACE, B-501,502,506*    198.50 MMBTU/H
REFORMER FURNACE, B-503,504,505*    536.90 MM3TU/H
C REFORMER, REGEN. VENT
A REFORMER FURNACE, B-102 - 106      93.10 MMBTU/H GAS
NOX


VOC



NOX


VOC



NOX

VOC

VOC
  0.0030 LB/MM8TU
 37.6000 LB/H
         LOW NOX BURNERS « LEA FIRING
  0.0030 LB/flfSTU
  0.6000 LB/H
         COM. CCNT. F. G. 02 METER
                              1
  0.1900 LB/MMBTU
101.7000 LB/H
         LCN NOX BURNERS
  0.0030 LB/MM3TU
  1.5000 LB/H
         CCM. CONT. F.G. 02 METER
                                                                            NONE
                                                                     0.9000 LB/H
                                                                     0.0100 M."3TU/H
                                                                            NONE
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
PAGE G- 352

-------
                                                           NOX      34.5000 LB/H                                             BACT
                                                                     0.0400 LB/MM3TU
                                                                            NONE
PAGE 6- 353

-------
(CONTINUED) CITIES SERVICE CO.
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
,..  &  BASIS
...  FCT  EFF
A REFORMER FURNACE, B-201
                                     64.80 MMBTU/H
A REFORMER FURNACE, B-202
B REFORMER FURNACE, B-401
B REFORMER FURNACE, B-406
B REFORMER FURN4CE, B-402
                                     53.00 HMBTU/H
                                     60.40 MMBTU/H
                                     57.30 MM3TU/H
                                     55.90 MMBTU/H
                     NOX      14.2000 LB/H
                               0.0003 LB/MMBTU
                                      NONE
                     VOC       0.2000 LB/H
                               0.0030 LB/MMBTU
                                      NONE

                     NOX      11.6000 LB/H
                               0.0003 LB/MMBTU
                                      NONE
                     VOC       0.2000 LB/H
                               0.0030 LB/MMBTU
                                      NONE

                     NOX      13.2000 LB/H
                               0.0003 LB/MMBTU
                                      NONE
                     VOC       0.2000 LB/H
                               0.0030 LB/MMBTU
                                      NONE

                     NOX      12.6000 LB/H
                               0.0003 LB/MMBTU
                                      NONE
                     VOC       0.2000 LB/H
                               0.0030 LB/MM3TU
                                      NCNE

                     NOX      12.2000 LB/H
                               0.0003 LB/MMBTU
                                      NONE
                     VOC       0.2000 LB/H
                               0.0030 LB/MMBTU
                                      NONE
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             EACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
PAGE G- 354

-------
 (CONTINUED) CITIES SERVICE CO.
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
...4  BASIS
,..  PCT  EFF
B REFORMER FURNACE, B-403,404,4*    330.00 MMBTU/H
COKER FURNACE, B-101
COKER FURNACES, B-201
TOPPER FURNACE, B-2C
POWER HOUSE BOILER, B-3, B-3B
                                    103.20 MMBTU/H
                                     82.40 MMBTU/H
                                     65.90 MMBTU/H
                                    173.00 MMBTU/H GAS
                     NOX      50.8000 LB/H
                               0.2200 LB/MMBTU
                                      NONE
                     VOC       2.3000 LB/H
                               0.0030 LB/MMBTU
                                      NONE

                     NOX      23.7000 LB/H
                               0.0030 LB/MMBTU
                                      NONE
                     VOC       0.3000 LB/H
                               0.0030 LB/MMBTU
                                      NONE

                     NOX      18.0000 LB/H
                               0.2200 LB/MMBTU
                                      NONE
                     VOC       0.2000 LB/H
                               0.0030 LB/MMBTU
                                      NONE

                     NOX      14.4000 LB/H
                               0.2200 LB/MMBTU
                                      NOME
                     VOC       0.2000 LB/H
                               0.0030 LB/MMBTU
                                      NCNE

                     NOX      60.5000 LB/H
                               0.0050 LB/MMBTU
                                      NCNE
                     VOC       0.9000 LB/H
                               0.0050 LB/f!M8TU
                                      NONE
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
PAGE G- 355

-------
(CONTINUED) CITIES SERVICE CO.
PROCESSES SUBJECT
TO THIS PERMIT
 THROUGHPUT
- CAPACITY
POLLUTANT    EMISSION LIMITS                                   ... £ BASIS
 EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
POWER HOUSE BOILER, B-A3.3C
                                    173.00 MMBTU/H
TANKAGE
REFINERY, MSC. SOURCES
COMPLEX COOLING TOWERS
                     NOX      60.5000  LB/H
                               0.3500  LB/MM3TU
                                       NONE
                     VOC       0.9000  LB/H
                               0.0050  LB/MMBTU
                                       NONE

                     VOC     581.7000  LB/H              \
                                       BACT  FOR  FUGITIVE'.HC

                     VOC     291.0000  LB/H
                                       BACT  FOR  FUGITIVE HC

                     VOC     234.4000  LB/H
                                       BACT  FOR  FUGITIVE HC
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             EACT
NOTES 	
REFINERY MODIFICATIONS INCLUDE: INSTALLATION OF NEW "C"  REFORMER,  REVISION OFREFINERY FUEL BALANCE,  INSTALLATION OF  AIR  PREHEA
T AND FLUE GAS WASTE HEAT BOILERS FOR EMERGENCY CONSERVATION,  CRUDE  DISTILLATION COLUMN MODIFICATION,
AND CONVERSION OF CONE ROOF TANKS TO INTERNAL FLOATING PANS.
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 356
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW STATUS:   04/01/19S3
                 ID NUMBER  LA-0033
                                                                     SCL'^CE TYPE CCDE    5.5

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1934
 SOURCE TYPE/SIZE—          PETROLEUM REFINING - AUXILIARY
 COMPANY NAME/SITE  LOCATION  CLARK OIL CO., WOOD RIVER REFIN.                               HARTFORD, IL 62048
                            P.O. BOX 7                                                                              MADISON COUNTY
                                                                                               DATE OF PERMIT ISSUANCE-  09/25/81
 DERMTTp  Mnr *v       T, , T.HTC „                                                        ESTIMATED DATE OF START-UP-   1986
 DETERMINATION MADE BY       ILLINOIS EPA                   CHRIS RONAINE                       ( 217J-732-2U3
                              (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)
TOTUT    SU3JECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                       * BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ...  PCT EFF


PROCESS HEATERS
                                                           NOX     389.3000  T/YR
                                                                            LCM NOX BURNERS
                                                           S02       1.0000  LB/MM3TU
                                                                            BURNING BYPRODUCT GAS WITH  OIL
                                                           PM       92.9000  T/YR

STORAGE TANKS                                              C°       55-5°°°  T/YR
                                                           VOC      70.2000  T/YR


NOTES -----------
NOX EMISSION LIMIT ON PROCESS HEATERS WILL BE SPECIFIED  UPON  SUBMISSION OF DETAILED ENGINEERING  SPECIFICATIONS.

ALSO PERMIT NUMBER 119 050 AAA.
(*> INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW                        ***

PAGE G" 357                                          10 NUMBER iL-0003

-------
                                             APPENDIX -- DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE-—         PETROLEUM REFINING - AUXILIARY


COMPANY NAME/SITE LOCATION  CLARK OIL, MT. AIRY REFINERY                                 SARYVILLE,  LA
                                                                                                           ST.  JOHN BAPTIST PARISH


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE  OF PERMIT ISSUANCE--  12/22/83
PERMIT NO. PSD-LA-392                                                                          ESTIMATED DATE OF  START-UP-
DETERMINATION MADE BY       LAQD/EPA REGION VI             BHARAT CONTRACTOR                    (50$)-342-3940
                             (AGENCY)                   (AGENCY  CONTACT PERSON)                     ( PHOK'E )



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    . ..  & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED           CONTROL EQUIPMENT  OR  PROCESS MODIFICATION   ...  PCT  EFF


RECOVERY UNIT, SULFUR                12.00 LT/D
                                                        ,   S02       50.0000 LB/H                                             B/A
                                                                           CATALYTIC  AFTER  BURNER                            96.00


NOTES 	
NSPS NOT APPLICABLE
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PA3E G- 358
             INITIAL P^VIEW  POST STARTUP
REVIEW STATUS--
                                                      ID NUH3ER  LA-0045
                                                                                                          SO'JPCE TYPE CCDE     5.5

-------
                                             APPENDIX -- DETAILED SOURCE LISTING
                                                                                                                        05/32/1984
SOURCE TYPE/SIZE—-
                            PETROLEUM REFINING - AUXILIARY
                                                                                             225.00 MBPSO
COMPANY NAME/SITE LOCATION  COASTAL STATES PETROLEUM
                            P.O. DRAWER 521
                                              CORPUS CHRISTI, TX 78043
                                                                                                                     NUECES COUNTY
DETERMINATION IS BACT FOR A MODIFIED SOURCE.
PERMIT NO. TX-243
DETERMINATION HADE BY       EPA REGION VI
                             (AGENCY)
                     JOHN BUNYAK
                  (AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE—  10/14/80
                                       ESTIMATED DATE OF START-UP--
                                       (2141-767-1594
                                           (PHCHE)
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
& BASIS
PCT EFF
INCIN.
                                     15.70 MMBTU/H
HEATER, COKER CHARGE
HEATER, FCCU FEED
                                    113.00 MMBTU/H
                                     65.00 MMBTU/H
                     NOX       2.3000 LB/H
                               0.1500 LB/MKBTU
                                      LEA FIRING
                     CO        0.3000 LB/H
                               0.0200 LB/MM3TU
                                      LEA FIRING

                     NOX      13.6000 LB/H
                               0.1200 LB/MMBTU
                                      LEA FIRING/LOW NOX BURNERS
                     CO        2.0400 LB/H
                               0.0200 LB/MMBTU
                                      LEA FIRING

                     NOX       7.8000 LB/H
                               0.1200 LB/MMBTU
                                      LEA FIRING/LOW NOX BURNERS
                     CO        1.1700 LB/H
                               O.OEOO LB/flMSTU
                                      LEA FIRING
                                                                     BACT


                                                                     BACT



                                                                     BACT


                                                                     BACT



                                                                     BACT


                                                                     BACT
PAGE G- 359

-------
(CONTINUED) COASTAL STATES PETROLEUM
PROCESSES SUBJECT
TO THIS PERMIT
 THROUGHPUT
  CAPACITY
POLLUTANT    EMISSION LIMITS                                   ... * BASIS
 EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
REBOILER, ISOSTRIPPER
                                     89.00 MMBTU/H
GAS OIL HDS HEATER
REBOILER, GAS OIL HDS
REBOILER, CRUDE UNIT
HEATER, VACUUM CHARGE
                                     73.00 MMBTU/H
36.00 MMBTU/H
                                     55.00 MMBTU/H
                                     51.00 MM3TU/H
   NOX      10.7000 LB/H
             0.1200 LB/MMBTU
                    LEA FIRING/LOW NOX BURNERS
   CO        1.6000 LB/H
             0.0200 LB/MMBTU
                    LEA FIRING

   NOX       8.8000 LB/H
             0.1200 LB/MMBTU
                    LEA FIRING/LOW NOX BURNERS
   CO        1.3100 LB/H
             0.0200 LB/MMBTU
                    LEA FIRING

   NOX       4.3000 LB/H
             0.1200 LB/MMBTU
                    LEA FIRING/LOW NOX BURNERS
   CO        0.6500 LB/H
             0.0200 LB/HMBTU
                    LEA FIRING

   NOX       6.6000 LB/H
             0.1200 LB/MMBTU
                    LEA FIRING/LOW NOX BURNERS
   CO        0.9900 LB/H
             0.0200 LB/MMBTU
                    LEA FIRING

   NOX       5.4000 LB/H
             0.1200 LB/KM3TU
                    LEA FIRING/LOW NOX BURNERS
   CO        0.9200 LB/H
             0.0£00 LB/MMBTU
                    LEA FIRING
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
PAGE G- 360

-------
 (CONTINUED) COASTAL STATES PETROLEUM

 PROCESSES SUBJECT
 TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT    EMISSION LIMITS                                    ... i BASIS
 EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ,.. PCT EFF
HEATER, CRUDE CHARGE
                                     45.00 MMBTU/H
HEATER, TAIL GAS UNIT
HEATER, REFORMER
HEATER, NAPTHA HDS
HEATER, KEROSENE HDS
                                      6.30 MMBTU/H
                                    123.00 MMBTU/H
                                     35.00 MMBTU/H
                                     16.30 MMBTU/H
                     NOX       5.4000 LB/H
                               0.1200 LB/MMBTU
                                      LEA FIRING/LOW NOX BURNERS
                     CO        0.8100 LB/H
                               0.0200 LB/MMBTU
                                      LEA FIRING

                     NOX       0.8000 LB/H
                               0.1200 LB/MMBTU
                                      LEA FIRING/LOW NOX BURNERS
                     CO        0.1100 LB/H
                               0.0200 LB/MMBTU
                                      LEA FIRING

                     NOX      14.8000 LB/H
                               0.1200 LB/MMBTU
                                      LEA FIRING/LOW NOX BURNERS
                     CO        2.2200 LB/H
                               0.0200 LB/MM3TU
                                      LEA FIRING

                     NOX       4.2000 LB/H
                               0.1200 LB/MMSTU
                                      LEA FIRING/LOW NOX BURNERS
                     CO        0.6300 LB/H
                               0.0200 LB/MMBTU
                                      LEA FIRING

                     NOX       2.0000 LB/H
                               0.1200 LB/MMBTU
                                      LEA FIRING/LOW NOX BURNERS
                     CO        0.2900 LB/H
                               0.0200 LB/MMBTU
                                      LEA FIRING
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
PAGE G- 361

-------
 (CONTINUED) COASTAL STATES PETROLEUM
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT    EMISSION LIMITS                                    ... t BASIS
 EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF
REBOILER, KEROSENE HDS
                                     12.50 MMBTU/H
HEATER, DIESEL HDS
REBOILER, DESIEL HDS
BOILER, UTILITY
BOILER, UTILITY
                                      9.10 MMBTU/H
                                     10.30 MMBTU/H
                                     83.00 MMBTU/H
                                     88.00 MMBTU/H
                     NOX       1.5000 LB/H
                               0.1200 LB/MMBTU
                                      LEA FIRING/LOW NOX BURNERS
                     CO        0.2300 LB/H
                               0.0200 LB/MMBTU
                                      LEA FIRING

                     NOX       1.1000 LB/H
                               0.1200 LB/MMBTU
                                      LEA FIRING/LOW NOX BURNERS
                     CO        0.1600 LB/H
                               0.0200 LB/MMBTU
                                      LEA FIRING

                     NOX       1.2000 LB/H
                               0.1200 LB/MMBTU
                                      LEA FIRING/LOW NOX BURNERS
                     CO        0.1800 LB/H
                               0.0200 LB/MMBTU
                                      LEA FIRING

                     NOX      10.6000 LB/H
                               0.1200 LB/MMBTU
                                      LEA FIRING/LOW NOX BURNERS
                     CO        1.6000 LB/H
                               0.0200 LB/flMBTU
                                      LEA FIRING

                     NOX      10.6000 LB/H
                               0.1200 LB/MMBTU
                                      LEA FIRING/LOW NOX BURNERS
                     CO        1.6000 LB/H
                               0.0200 LB/MMBTU
                                      LEA FIRING
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
PAGE G- 362

-------
(CONTINUED) COASTAL STATES PETROLEUM
PROCESSES SUBJECT                      THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                    ...  t BASIS
TO THIS PERMIT                          CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ...  PCT EFF
— — — — —	— — — —. — -. — — — — -. — -._ — — — .._,»_,»,. — ..__..,_ __.,___ __ ______ -.__•-.»_ — __*. — _ _______ ___.•..«,_.._.. __.._-..._•„.__..___.._ «. — — _ — «. — ». __«.^^ __*_«. __^._« — ___^-.___ w.^^.

REGENERATOR, FCCU
                                                            NOX     160.0000 LB/H                                              BACT
                                                                             NONE
                                                            CO      103.9000 LB/H                                              BACT
                                                                             HIGH TEMP.  REGENERATION


NOTES 	
CAPACITY INCREASE FROM 185 TO 225 MBPSD.
                                                                                                        INITIAL  REVIEW  POST STARTUP
(*) INDICATES DATUM WAS  TRUNCATED  FOR  THIS TABLE.                                          REVIEW STATUS:  04/01/1983
PAGE G- 363                                            ID NUMBER TX-0066                                      SOURCE  TYPE CODE    5.5

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE—
                            PETROLEUM REFINING - AUXILIARY
                                                                                           12000.00 BPSD
COMPANY NAME/SITE LOCATION  CONOCO, INC.
                            LAKE CHARLES REFIN.
                                                    MESTLAKE, LA
                                                                                                                  CALCASIEU PARISH
DETERMINATION IS BACT FOR A MODIFIED SOURCE.
PERMIT NO. (REGION FILE NO.) PSD-LA-419
DETERMINATION MADE BY       EPA REGION VI
                             (AGENCY)
                     JOHN BENHAM
                  (AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE—  10/08/81
                                       ESTIMATED DATE OF START-UP--   1982
                                       (214)-767-1594
                                           (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT    EMISSION LIMITS                                   ... t BASIS
 EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
HEATER, HDS CHARGE
REBOILER, HDS STRIPPER
HEATER, REFORMER CHARGE
HEATER, INTERPASS
HEATER, INTERPASS
                                     39.00 MMBTU/H
                                     39.00 MMBTU/H
                                     52.00 MMBTU/H
                                     46.00 MMBTU/H
                                     37.00 MMBTU/H
                     NOX       0.1200 LB/MMBTU
                                      LOW NOX BURNERS
                                      LOW EXCESS AIR

                     NOX       0.1200 LB/MMBTU
                                      LOW NOX BURNERS
                                   ,   LOW EXCESS AIR

                     NOX       0.1200 LB/MMBTU
                                      LOW NOX BURNERS
                                      LOW EXCESS AIR

                     NOX       0.1200 LB/MMBTU
                                      LCW NOX BURNERS
                                      LOW EXCESS AIR

                     NOX       0.1200 LB/MMBTU
                                      LOW NOX BURNERS
                                      LOW EXCESS AIR
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
PAGE G- 364

-------
 (CONTINUED) CONOCO,  INC.
 PROCESSES SUBJECT
 TO THIS PERMIT
THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... ft BASIS
 CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
REBOILER, DEPROPANIZER
                                     32.00 MMBTU/H
                                                           NOX       O.ieOO LB/MMBTU
                                                                            LOW NOX BURNERS
                                                                            LOW EXCESS AIR
                                                                                       BACT
NOTES
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 365
                                                                TMTTUl REVIEW  POST STARTUP
                                                  REVIEW  STATUS:   0
-------
                                             APPENDIX ~  DETAILED  SOURCE LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE—-
                            PETROLEUM REFININS - AUXILIARY
                                                                                          100000.00  BBL/D
COMPANY NAME/SITE LOCATION  CONOCO, INC.
                            LAKE CHARLES REFIN.
                                                                                          WESTLAKE,  LA
                                                                            CALCASIEU PARISH
DETERMINATION IS BACT FOR A MODIFIED SOURCE.
PERMIT NO. (REGION FILE NO.) PSD-LA-390
DETERMINATION MADE BY       EPA REGION VI
                             (AGENCY)
                     TOM DIGGS
                  (AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE—  08/10/81
                                       ESTIMATED DATE OF START-UP—   1933
                                       (214)-767-1594
                                           (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
...  i.  BASIS
. ..  PCT  EFF
COKER HEATERS, 2 DELAYED REG.
                                     99.00 MMBTU/H
HEATER, CRACKED DISTIL HYDRO OE*     16.00 MMBTU/H
HEATER, HEAVY VACUUM GAS OIL HY*     15.00 MMBTU/H
INCIN., SULFUR RECOVERY PLANT
                                      9.68 MMBTU/H
                     NOX       0.1200 LB/MKBTU
                                      LOW NOX BURNER
                                      LOW EXCESS AIR

                     NOX       0.1200 LB/MMBTU
                                      LOW NOX BURNER
                                      LOW EXCESS AIR

                     NOX       0.1200 LB/MMBTU
                                      LOW NOX BURNER
                                      LOU EXCESS AIR

                     NOX       0.1200 LB/WBTU
                                      LOW NOX BURNER
                                      LOW EXCESS AIR
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
NOTES 	
<* FUEL GAS-HEATERS.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 366                                           ID  NUMBER  LA-0010
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW STATUS:   04/01/1933
                                                                     SOURCE  TYPE CODE     5.5

-------
                                            APPENDIX ~ DETAILED SOURCE LISTING
                                                                                                                        05/23/1984
SOURCE TYPE/SIZE—
                            PETROLEUM REFINING - AUXILIARY
                                                                                          48000.00 BBU/D
COMPANY NAME/SITE LOCATION  CRA.INC.
                                                                                      COFFEYVILLEt KS
                                                                                                                MONTGOMERY COUNTY
DETERMINATION IS BACT FOR A MODIFIED SOURCE.
PERMIT NO.
DETERMINATION MADE BY       EPA REGION VII
                             (AGENCY)
                     DANIEL RODRIGUEZ
                  (AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE—  09/04/80
                                       ESTIMATED DATE OF START-UP—
                                       (816)-3?4-6525
                                           (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT    EMISSION LIMITS
 EMITTED            CONTROL EQUIPMENT 03 PROCESS MODIFICATION
,..  & BASIS
. ..  PCT  EFF
HEATER, UNIT 40 (RETROFIT)
                                     51.00  MHBTU/H
HEATER, UNIT 41 (BUILT, BUT NOT»     32.00  MMBTU/H

HEATER, UNIT 42 (RELOCATE)          136.00  MMBTU/H
HEATER, UNIT 43 (RELOCATE)
HEATER, UNIT 44 (NEW)
HEATER, UNIT 45 (NEW)
                                     27.60  MHBTU/H
                                     21.70  MM3TU/H
                                     62.20  MMBTU/H
                     NOX       0.1300 LB/MMBTU
                                      LOW NOX BURNERS

                     NOX       0.1500 LB/MMBTU

                     NOX       0.1600 LB/MMBTU
                                      CONVENT. BURN W/AIR PREHEAT

                     NOX       0.1300 LB/MMBTU
                                      LOW NOX BURNERS

                     NOX       0.1300 LB/MMBTU
                                      LOW NOX BURNERS

                     NOX       0.1300 LB/MMBTU
                                      LOW NOX BURNERS
                                                                     BACT


                                                                     BACT

                                                                     BACT


                                                                     BACT


                                                                     BACT


                                                                     BACT
NOTES 	
LIMITS FOR UNITS 42 4 43 WERE AMMENDED  FROM  0.15  LB/KM5TU ON JULY 6,  1981. SIZE  IS REFINERY CAPACITY. UNITS  41  &  42  EQUIPPTED
WITH CONVENTIONAL BURNERS.
(*) INDICATES DATUM WAS TRUNCATED FOR  THIS TABLE.

PAGE G- 367
                                                                INITIAL f^VIEW  POST STARTUP
                                                   REVIEW STATUS:   04/01/1933
                                                     ID NUMBER KS-0003
                                                                                                           SOURCE  TYPE  CODE     5.5

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                         05/82/1984
SOURCE TYPE/SIZE—         PETROLEUM REFINING - AUXILIARY                                 30000.00 BBL/D


COMPANY NAME/SITE LOCATION  CYPRESS REFINING CO., HILL PETROLEUM CO.                 KROTZ SPRINGS, LA
                                                                                                                 ST.  LANDRY PARISH
DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE—   01/03/84
PERMIT NO. PSD-LA-504                                                                          ESTIMATED DATE OF START-UP—    1932
DETERMINATION MADE BY       LAQD/EPA REGION VI             BHARAT CONTRACTOR                   (504)-3<*2-8940
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    . .. «  BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF
_..___«.__..	— — «. — — _-.—._„— — _ — __•_ — _»___-._».„—_«_«.. __ — _ — —__ — _	— — -, — — — — — — — — — _-, — ——.-.-._ — —, — _—_ — «,_-. — — _-._ — _ — —— ^_ — — _w____.__ —_«._«.__„_«.___________

BOILER, Sl-82                        99.50 MMBTU/H
                                                           NOX      15.3200 LB/H                                              BACT
                                                                            COMB. CONTRL W/02 MONITOR
                                                           VE       20.0000 y. OPACITY      "                                   BACT
                                                                            COMB. CONTRL W/02 MONITOR
BOILER, #2-82                        99.50 MMBTU/H
                                                           NOX      17.5100 LB/H                                '              BACT
                                                                            COMB. CONTRL W/02 MONITOR
                                                           VE       20.0000 V. OPACITY                                         BACT
                                                                            COMB. CONTRL W/02 MONITOR


NOTES 	
BOTH BOILERS ARE FIRED WITH REFINERY FUEL GAS. BOTH BOILERS HAVE THE SAME RATED HEAT INPUT, HOWEVER, THE EMISSION RATES FOR NO
X ARE DIFFERENT DUE TO DIFFERENT FIRE BOX CONFIGURATION.
                                                                                                      INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEW STATUS:
PAGE G- 368                                           ID NUMBER LA-0027A                                   SOURCE TYPE CODE    5.5

-------
                                             APPENDIX — DETAILED SOURCE LISTING
 ===================	               _                                                   05/22/19S4


 SOURCE TYPE/SIZE—          PETROLEUM REFINING - AUXILIARY                                 60000.00 BBL/D


 COMPANY NAME/SITE  LOCATION  DIAMOND SHAMROCK CORP.                                        AMARILLO, TX 77173
                                 BOX 631                                                                              MOORE COUNTY


                                                                                               DATE OF PERHIT ISSUANCE-  09/04/81
 nFTFpMTNATTfiw  M*nc nv        c0. or--™                                                         ESTIMATED DATE OF START-UP-
 DETERMINATION  MADE BY        EPA REGION VI                  JOHN BUNYAK                         C214}-76?-159<*
                              (AGENCY!                   (AGENCY CONTACT PERSON)                    (FHONE)



 PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                       4 BASIS
 ______                                CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
 PROCESS BOILER, Z
FCCU REGEN STACK, 2
                                    240.00 MM3TU/H
                                  45000.00 BBL/D
S02     103.6700 LB/H
                 SCRUB FUEL G./.7X S FUEL OIL
NOX     130.0000 LB/H
                 LOW NOX BURNERS
CO        6.8100 LB/H
                 EFFICIENT COMBUSTION
PM       10.0600 LB/H
                 SCRUB FUEL S./.7X FUEL OIL

S02     931.5000 LB/H
                 NONE
NOX      24.4000 LB/H
                 HIGH TEMP REGENERATION
CO      195.0000 LB/H
                 HIGH TEMP RENERATION
PM       22.7000 LB/H
                 ESP
B/N

BACT

BACT

BACT


BACT

BACT

BACT

BACT
98.80
NOTES
(*> INDICATES DATUM WAS TRUNCATED FOR THIS  TABLE.

PAGE G- 369
                                           INITIAL REVIEW  POST STARTUP
                              REVIEW STATUS:  04/01/1933
                                                      ID NUMBER TX-0034
                                                                                                           SCUPCE TYPE CODE
                                                                                                                               5.5

-------
                                              APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                          05/22/1984



SOURCE TYPE/SIZE—          PETROLEUM REFINING - AUXILIARY
                            —	— — —	— — — —• —	*._ — — »-. — —* — — -.-.«. — — » — — — _ — — -._ — -. — _-. — — _-.-. — _ — «__	-. — __,._.. — .._._-._.,...._..,_	— — _........«._—..__,.__..___...___

COMPANY NAME/SITE  LOCATION  EXXON CHEMICAL AMERICAS                                         BAYTOWN,  TX 77520
                                                                                                                       HARRIS COUNTY


DETERMINATION IS BACT  FOR  A MODIFIED SOURCE.                                                    DATE  OF PERMIT ISSUANCE—  07/30/81
PERMIT NO. (REGION FILE  NO.) PSD-TX-302                                                         ESTIMATED DATE OF START-UP—   1984
DETERMINATION MADE BY        EPA REGION VI                  TOM DIGGS                            (214)-767-1594
                              (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                      THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... & BASIS
TO THIS PERMIT                          CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ... PCT EFF
•- — — — — — —— .._ .- _ _ _ ««.. ______ __ _•.»__,„«.__•,•., —_ _.«•.__,..»»™...^_ — w_ ,—— •— __ ____ ______ __ «.«_v»«-.v»-<_..«>~ _« — — __,_•__»•__«___«_ ——•.—.™,..^ —^•_«™-,-_«.«_ —•.•„,,.^_

HEATERS, NAT. GAS-FIRED, 3 EA       275.00 MMBTU/H
                                                            NOX       0.2300 LB/MMBTU                                          BACT
                                                                             CONTROL OF EXCESS OXYGEN


NOTES 	
EPA ORIGINALLY SPECIFIED 0.12 LB/MMBTU AS BACT, BUT EXXON PROVIDED INFORMATION ON THE HEATER  DESIGN  AND TEST DATA ON SIMILIAR
HEATERS TO JUSTIFY THE NEED FOR0.23 LB/MMBTU.
(*) INDICATES DATUM WAS TRUNCATED  FOR  THIS  TABLE.

PAGE G- 370
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS:  OVOl/1963
                                                       ID NUMBER  TX-0046
                                                                                                            SOURCE  TYPE CODE    5.5

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                         05/22/1984
SOURCE TYPE/SIZE—         PETROLEUM REFINING - AUXILIARY


COMPANY NAME/SITE LOCATION  EXXON CO, USA                                                  BENICIA, CA
                           __,	— «.	—— __	.„_».».__.„	„.	— __ — — _ —	«_^ — _ —__ — — — — -.«.— — — -. — — — _ — — — — — — — — — — — — —— — — — — — — — —— — — — —— — — — —— — — — —— — — — —

DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—  12/10/80
PERMIT NO. 27599                                                                               ESTIMATED DATE OF START-UP--    1932
DETERMINATION MADE BY       BAY AREA AQMD                  LEONARD CLAYTON                     (415)-7?l-6000
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... S  BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF
.. __ — ___•._____—»_ — _ _ _ __ _ _ ____ ___ — __., — _ — — ____-._ — — ______>.___ ___ ___ __,-____. — ..__ — .__ — — _ — — -. — — — — •. — -- — — — — — — — — — — — — — —. — —._____._ _ — — _ — ___ — •_ — — — — — — —

FURNACE, REFINERY PROCESS           165.00 MfiBTU/H
                                                           NOX      ^0.0000 PPM AT 3X 02
                                                                   207.0000 LB/D
                                                                            LOW NOX BURNERS & THERMAL DE-NOX                  70.00


NOTES 	
DEMONSTRATED TECHNOLOGY. FILE A 310-010
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 371
                                                                                                       INITIAL REVIEW  POST STARTUP
                                                                                          REVIEW STATUS;   04/19/1934
ID NUMBER CA-0057
                                                      SOURCE  TYPE  CODE    5.5

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                         05/22/1964



SOURCE TYPE/SIZE—         PETROLEUM REFINING - AUXILIARY                                 30000.00 BPSD
                           •___—___—— _ _ — — .. _ — __ — — _____________ _ _ __ — _..____ __ .».._ — — •_ — „.... — — — — ,— — — — — — •. — — — — — •.-. — — ~ — — — — —. — .— — — — •».•• — — — .*-•— — — — — — —• —

COMPANY NAME/SITE LOCATION  FRIENDSWOOD REFIN.                                             HOUSTON, TX
                            CHOATE ROAD                                                                              HARRIS COUNTY


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE—   06/30/81
PERMIT MO. (REGION FILE NO.) PSD-TX-387                                                        ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY       EPA REGION VI                  JOHN BUNYAK                         (2141-767-1594
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... * BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
HEATERS, 4
                                     75.00 MMBTU/H
BOILER
                                     40.00 MMBTU/H
SULFUR RECOVERY UNIT
PM        0.0042 LB/MMBTU
                 GAS FIRED
S02       0.0224 LB/MMBTU
                 REFINERY GAS FIRED
NOX       0.1000 LB/MMBTU
                 LOW NOX BURNERS
CO        0.0142 LB/MKBTU
                 EFFICIENT COMBUSTION

PM        0.0042 LB/MM3TU
                 GAS FIRED
S02       0.0214 LB/MMBTU
                 REFINERY GAS FIRED
NOX       0.1000 LB/MMBTU
                 LOW NOX BURNERS
CO        0.0142 LB/TMSTU
                 EFFICIENT COMBUSTION

S02       9.1500 LB/H
                 CLAUS PLANT
BACT

KSPS

BACT

BACT


BACT

NS~S

EiCT

BACT
                                                                                                                              BACT
                                                                                                                              
-------
 (CONTINUED)  FRIENDSWOOD REFIN.
 PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... t BASIS
 TO  THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
                                                 •	.	

 FCCU REGENERATOR
                                                           PM       Z
-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE—         PETROLEUM REFINING - AUXILIARY                                   350.00 MMBTU/H


COMPANY NAME/SITE LOCATION  GETTY OIL CO.                                              BAKERSFIELD, CA 93308
                            ROUTE 1, BOX 197-X
                           _ ____-—.—__—___ — — __-.___ — -.—_ — ..... ~ ___~ ___~_ _,_ — __«_. __ __ ___ _ __«.— _ _,- — _ _ ^ ~ ,.—. _ __„.._ __ v — __«.— _ _.,_«__-»«_w_.__ — «« —

DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE—  08/24/8Z
PERMIT NO. SJ-81-11                                                                            ESTIMATED DATE OF START-UP—
DETERMINATION MADE BY       EPA REGION IX                  JOE SLAMOVICH                       (415J-974-S235
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... t BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
WIKAW — — >• •._VB*M__*»«M_wb_v-»-~ _• — — >. — — .._._».___ -. — ___«.»««»««.. — — •,«.—i_— «.»— — _•.-.—_—— ——— — — ——— — -.— — — — ^ — ——————— — — — — — — — — ———-. ••— — — —— — — — — — — — — — — — — «. — »

STEAM GENERATOR, 7                  240.00 B3L/D
                                                           NOX       0.1500 LB/MMBTU PER GEN.
                                                                            AMMONIA INJECTION                                63.00


NOTES 	
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 374
ID NUMBER CA-0030
                                                INITIAL REVIEW  POST STARTUP
                                     VICrt' STATUS:  C-t/ul/lcS3    04/04/1934

                                                     SOURCE TYPE CODE    5.5

-------
                                             APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                         05/22/1984
rr======r===r================================r-=---__-_-_-_-____=___.__^


SOURCE TYPE/SIZE—          PETROLEUM REFINING - AUXILIARY                                 350000.00  BPSD


COMPANY NAME/SITE LOCATION   6000 HOPE REFIN., INC.                                        6000  HOPE,  LA 70079
                             P.O. BOX 126, 257 PROSPECT AV*                                                       ST. CHARLES PARISH
                            •"••"• — — — — •- — •- — —— — -» — — — — — — — — — — — «. — — __—,^«.^.__-,^».—.«._ — _ _^.__ __ _ _ »__ —•^•__»___„._„__,,—.__ — _ „.„„_ _______ __ _ _ _ _«.«,__ ________

DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE  OF PERMIT ISSUANCE—  05/08/81
PERMIT NO.                                                                                      ESTIMATED DATE OF START-UP—
DETERMINATION MADE BY        EPA REGION VI                  JOHN BUNYAK                          (214>-767-1594
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... t BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT  OR  PROCESS MODIFICATION  ... PCT EFF
STRIPPER REBOILER
                                     26.00 MMBTU/H
REFORMER STABILIZER
                                     26.00 MMBTU/H
PM        0.3000  LB/H
          0.0110  LB/MMBTU
                  GASEOUS FUEL
S02       0.5000  LB/H
          0.0190  LB/MM3TU
                  0.10 GRH2S/DSCF
NOX       3.1000  LB/H
          0.1200  LB/MM3TU
                  LOW NOX BURNERS,  LEA  FIRING
CO        0.4000  LB/H
          0.0140  LB/MMBTU
                  COMBUSTION CONTROL

PM        0.3000  LB/H
          0.0110  LB/MMBTU
                  GASEOUS FUEL
S02       0.5000  LB/H
          0.0190  LB/MMBTU
                  0.10 GRH2S/DSCF
NOX       3.1000  LB/H
          0.1200  LB/MMBTU
                                                                                                                              BACT
                                                                                                                              NSPS
                                                                                                                              BACT
                                                                                                                              BACT
                                                                                                                              BACT
                                                                                                                              NSPS
                                                                                                                              BACT
PAGE G- 375

-------
                                                                            LOW NOX BURNERS, LEA FIRtNS
                                                           CO        0.4000 LB/H                                             BACT
                                                                     0.0140 LB/MHBTU
                                                                            COMBUSTION CONTROL
PAGE 6- 376

-------
 (CONTINUED)  GOOD  HOPE REFIN., INC.
 PROCESSES  SUBJECT
 TO  THIS  PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT    EMISSION LIMITS                                   ... 4 BASIS
 EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
 CRUDE HEATER
                                    317.00 MMBTU/H
FCCU FURNACE
                                     45.00 MMBTU/H
FCCU FURNACE
                                     39.00 MMBTU/H
                     PM        3.4000 LB/H
                               0.0110 LB/MMBTU
                                      GASEOUS FUEL
                     S02       6.1000 LB/H
                               0.0190 LB/MMBTU
                                      0.10 GRH2S/DSCF
                     NOX      38.0000 LB/H
                               0.1200 LB/MMBTU
                                      LOW NOX BURNERS,  LEA FIRING
                     CO        4.5000 LB/H
                               0.0140 LB/MM3TU
                                      COMBUSTION CONTROL

                     PM        0.5000 LB/H
                               0.0110 LB/MMBTU
                                      GASEOUS FUEL
                     302       0.9000 LB/H
                               0.0190 LB/MMBTU
                                      0.10 GRH2S/DSCF
                     NOX       5.4000 LB/H
                               0.1200 LB/MMBTU
                                      LOW NOX BURNERS,  LEA FIRING
                     CO        0.6000 LB/H
                               0.0140 LB/MMBTU
                                      COMBUSTION CONTROL

                     PM        0.4000 LB/H
                               0.0110 LB/MMBTU
                                      GASECUS FUEL
                     S02       0.7000 LB/H
                               0.0190 LB/MMBTU
                                      0.10 GRH2S/DSCF
                     NOX       4.7000 LB/H
                               0.1200 LB/MMBTU
                                      LOW NOX BURNERS,  LEA FIRING
                     CO        0.6000 LB/H
                               0.0140 LB/MMBTU
                                                                     BACT


                                                                     NSPS


                                                                     BACT


                                                                     BACT



                                                                     BACT


                                                                     NSPS


                                                                     BACT


                                                                     BACT



                                                                     BACT


                                                                     NSPS


                                                                     BACT


                                                                     BACT
PAGE G- 377

-------
                                                                           COMBUSTION CONTROL
PAGE 6- 378

-------
 (CONTINUED) GOOD HOPE REFIN., INC.
 PROCESSES SUBJECT
 TO THIS  PERMIT
THROUGHPUT        POLLUTANT    EMISSION LIMITS
 CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION
...  ft  BASIS
...  PCT  EFF
VACUUM COLUMN FURNACE
                                    244.00 MMBTU/H
DEMEX HEATER
                                     25.00 MKBTU/H
VISEBREAKING FURNACE, 3 EA
                                     40.00 MMBTU/H
                     PM        2.6000 LB/H
                               0.0110 LB/MMBTU
                                      GASEOUS FUEL
                     S02       4.7000 LB/H
                               0.0190 LB/MMBTU
                                      0.10 GRH2S/DSCF
                     NOX      29.3000 LB/H
                               0.1200 LB/MHBTU
                                      LOW NOX BURNERS,  LEA FIRING
                     CO        3.5000 LB/H
                               0.0140 LB/MMBTU
                                      COMBUSTION CONTROL

                     PM        0.3000 LB/H
                               0.0110 LB/MMBTU
                                      GASEOUS FUEL
                     S02       0.5000 LB/H
                               0.0190 LB/MtlBTU
                                      0.10 GRH2S/DSCF
                     NOX       3.0000 LB/H
                               0.1200 LB/MMBTU
                                      LOW NOX BURNERS,  LEA FIRING
                     CO        0.4000 LB/H
                               0.0140 LB/MMBTU
                                      COMBUSTION CONTROL

                     PM        0.4000 LB/H
                               0.0110 LB/MMBTU
                                      GASEOUS FUEL
                     S02       0.8000 LB/H
                               0.0190 LB/MMBTU
                                      0.10 GRH2S/DSCF
                     NOX       4.6000 LB/H
                               0.1200 LB/MHBTU
                                      LOW NOX BURNERS,  LEA FIRING
                     CO        0.6000 LB/H
                               0.0140 LB/MMBTU
                                                                                                                             BACT
                                                                                                                             NSPS
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             NSPS
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             NSPS
                                                                                                                             BACT
                                                                                                                             BACT
PAGE G- 379

-------
                                                                           COMBUSTION CONTROL
PAGE G- 380

-------
 (CONTINUED) GOOD HOPE REFIN.,  INC.
PROCESSES SUBJECT
TO THIS PERMIT
FCCU REGENERATOR







SULFUR PLANT INCIN.


THROUGHPUT POLLUTANT
CAPACITY EMITTED
82000.00 BBL/D
PM

S02

NOX

CO

S02

EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

64.9000 LB/H
THIRD-STAGE CYCLONE SEPARATOR
761.7000 LB/H
SULFUR REDUCTION CATALYST
242.6000 LB/H
LEA FIRING
138.6000 LB/H
COMBUSTION CONTROL
12.8000 LB/H
TAIL-GAS TREATMENT (SCOT)
... ft BASIS
... PCT EFF

NSPS
95.00
BACT

BACT

NSPS

NSPS
93.00
NOTES
<») INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.
= = = = r:::::r = :: = = = = = = = = = = : = - = = = = = = = = : = = r = = = = = = = = = = = = = = :

PAGE G- 301
             INITIAL REVIEW   POST STARTUP
REVIEW STATUS;  04/01/1933
                                                      ID NUMBER LA-0032
                                                                                                            SOURCE  TYPE CODE
                                                                                                                                5.5

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/23/1984
                        		—	— — —	—	— — •£ — — •£—— — — ~z:~~~~ — —~ — ~ — ~ —— — — ~~ —~ — ~ — — — —~ — — — ~ ——
— ~z: — — ~~~~ — — — ~~~ — ~ — — ~ — — — —	—	~	~	


SOURCE TYPE/SIZE—         PETROLEUM REFINING - AUXILIARY
                           	

COMPANY NAME/SITE LOCATION  GULF OIL CO.                                               PORT ARTHUR, TX 77640                ,.„,„„
                            20 M SE BEAUMONT H 73                                                                 JEFFERSON COUNTY
                                          _  _ — — ., — ___ — — — — .. — _ — — _ — — _ — — — — — — — — — — _,» — — — — — .. — —— — — — — — ••- — — — ___„_ — .. — — — .._ — —• — — — «• — — — — — — —— — — — — — — ••- —


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE—  10/13/81
PERMIT NO. (REGION FILE NO.) PSQ-TX-214                                                        ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY       EPA REGION VI                  JOHN BUNYAK                         < 214 )-767-159"+  v
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)

==:================r===:===rr:===:======r========:=r==r===r===r=======r===========rrrrr====^2=====================================

PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... t BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
HEATERS, 4 EA
                                    £(25.00 MMBTU/H
TREATING UNIT, SCOT TAIL GAS
     NOX       0.3000 LB/MMBTU
                      AIR/FUEL RATIO
     S02       0.5800 LB/^3TU
                      LOW SULFUR FUEL ( .5 7. S)
     CO        0.0370 LB/MMSTU
                      EFFICIENT COMBUSTION
     PM        0.0580 LB/MK3TU
                      EFFICIENT COMBUSTION

     S02      70.4000 LB/H
                      DESULFURIZED FUEL
BACT

NSPS

BACT

BACT


NSPS
NOTES
(*) INDICATES DATUM WAS TRUNCATED  FOR THIS TABLE.

PAGE G- 3S2
                                                                                                      INITIAL REVIEW   POST  STARTUP
                                                                                         REVIEW STATUS;   04/01/1933
ID NUMBER TX-0049
                                                     SOURCE TYPE CODE
                                                                         5.5

-------
                                             APPENDIX —  DETAILED  SOURCE LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE—
                            PETROLEUM REFINING -  AUXILIARY
COMPANY NAME/SITE LOCATION  GULF OIL CO.
                            P.O. BOX 701
                              PORT AURTHER, TX 77640
                                                                                                                  JEFFERSON COUNTY
DETERMINATION IS BACT FOR A MODIFIED SOURCE.
PERMIT NO. TX-342
DETERMINATION MADE BY       EPA REGION VI
                             (AGENCY)
   JOHN BUNYAK
(AGENCY CONTACT PERSON)
DATE OF PERMIT ISSUANCE--  10/21/80
ESTIMATED DATE OF START-UP--
(214J-767-1594
    (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
SOLVENT EXTRACTION UNIT 81843






LUBE VACUUM UNIT *147






GULFINING UNIT 3243






THROUGHPUT POLLUTANT
CAPACITY EMITTED
122.30 MMBTU/H
S02


NOX


124.30 MMBTU/H
S02


NOX


66.70 MMBTU/H
S02


NOX


: = = = = = r = rr = - = rr = r = = =rrrr = r:rrr = rr = = = = r = r = r = = r^: = = r = = rrr
EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

2.0000 LB/H
0.0200 LB/MM3TU
NAT. GAS/REFIN. GAS, TRACE H2S
14.6700 LB/H
0.1200 LB/MMBTU
LEA CONTROLS, LN5

72.3000 LB/H
0.6000 LB/HMSTU
NAT. GAS/REFIN. GAS, TRACE H2S
37.3000 LB/H
0.3000 LB/W1BTU
LEA CONTROLS, LN3

38.3000 LB/MM3TU
0.6000 LB/H
NAT. GAS/REFIN. GAS, TRACE H2S
20.0000 LB/H
0.3000 LB/MMBTU
LEA CONTROLS, LNB
... & BASIS
. . . PCT EFF

NSPS


BACT



NSPS


BACT



NSPS


BACT


PAGE G- 383

-------
(CONTINUED) GULF OIL CO.
PROCESSES SUBJECT
TO THIS PERMIT
CATALYTIC DEWAXING UNIT #1944


•



SULFUR RECOVERY UNIT 8544




SOLVENT DEWAXING UNIT






SOLVENT DEWAXING UNIT 81943






GULFINING UNIT 8244





• THROUGHPUT POLLUTANT
CAPACITY EMITTED
20.00 MMBTU/H
S02


NOX


15.70 MMBTU/H
S02

NOX

100.10 MMBTU/H
S02
^

NOX


35.60 MMBTU/H
S02


NOX


60.00 MMBTU/H
S02


NOX

EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATICN

11.6000 LB/H
0.6000 LB/MMBTU
NAT. GAS/REFIN. GAS, TRACE H2S
6.0000 LB/H
0.3000 LB/MMBTU
LEA CONTROLS, TRACE H2S

45.0000 LB/H
NAT. GAS FIRED
1.9000 LB/H
LEA CONTROLS, LNB

3.0000 LB/H
0.03"00 LB/MMBTU
NAT. GAS/REFIN. GAS, TRACE H2S
67.4000 LB/H
0.67CO LB/MMBTU
NONE
,
1.1000 LB/H
0.0300 LB/KM3TU
REFIN. GAS/NAT. GAS, TRACE H2S
23.9000 LB/H
0.6700 LB/HM3TU
N3HE

34.9000 LB/H
0.6000 LB/MI3TU
0.5X S IN OIL
18.0000 LB/H
0.3000 LE/HMSTU
... * BASIS
... PCT EFF

NSPS


BACT



NSPS
99.90
BACT


NSPS


BACT



NSPS


BACT



NSPS


BACT

                                                                            LEA  CONTROL,  LNS
PAGE G- 384

-------
(CONTINUED) GULF OIL CO.
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
...  *  BASIS
...  PCT  EFF
DELAYED COKING UNIT
                                    116.00 MMBTU/H
                                                           S02        3.5000  LB/H
                                                                     0.0200  LB/MMBTU
                                                                            TRACE  H2S
                                                           NOX       13.9000  LB/H
                                                                     0.1200  LB/MMBTU
                                                                            LEA FIRING,
                                                  LNB
                                                                                       NSPS
                                                                                       BACT
NOTES 	
SOLVENT DEWAXING UNIT 81943: CHANGE FUEL TYPE FROM REFINERY  GAS  ONLY TO REFINERY  GAS/NATURAL EAS.  LNB
E H2S -- <0.10 GR H2S/DSCF.
                                                                —  LOW NOX BURNERS.  TRAC
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 385
                                                                INITIAL RfVIEW   POST  STARTUP
                                                  REVIEW STATUS:   04/01/1933
                                                      ID NUMBER TX-0062
                                                                                                           SOURCE  TYPE  CODE
                                                                                                                               5.5

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984




SOURCE TrPE/SIZE—         PETROLEUM REFINING - AUXILIARY
                           _ ________ _________ — __ _».», — _ — _ — -,« — — — «. — — — — — —— — — — —• — — — —•.__ — — — — — __ — —. — .- — — — — — — — — — — — — — *. — — — — .••.• — — — — .— — — — .- — — — — •.•- — — — — — —

COMPANY NAME/SITE LOCATION  HAWAIIAN INDEPEN. REFIN.                                     EWA BEACH, HI


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE—  03/18/81
PERMIT NO. (REGION FILE NO.) HI 81-01                                                          ESTIMATED DATE OF START-UP—
DETERMINATION MADE BY       EPA REGION IX                  DENNIS BEAURE6ARD                   (415)-974-8236
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... 4 BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... FCT EFF
HEATER, CRUDE OIL,
                                    110.00 MMBTU/H
REFORMER FURNACE, HZ GEN. PUNT     125.00 MMBTU/H
     NOX       0.4000 LB/MMBTU
                      LOW NOX BURNERS
     S02      60.0000 LB/MMBTU
                      0.57. S S6 FUEL OIL
     PM        6.1000 LB/H
                      0.5X S 86 FUEL OIL

     NOX       0.1700 LB/MMBTU
                      LOW NOX BURNERS
     S02       2.4000 LB/H
                      BURN REF GAS - 0.1 GR H2S/DSCF
     PM        1.4000 LB/H
                      NOME
NOTES 	
BACT IS DETERMINED BY TECHNOLOGY AND ECONOMICS. FACILITY EXPANSION FROM 95000 BBL/DAY TO 125000 B5L/DAY BY INSTALLATION OF A H
EATER AND HYDROGENATION PLANT.
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 386
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW STATUS:  04/01/1933
ID NUMBER HI-0001
                                                     SOURCE TYFE CODE
                                                                         5.5

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984
 SOURCE  TYPE/SIZE ---          PETROLEUM REFINING - AUXILIARY
                            " --~   ---     __   ---__--^__

 COMPANY NAME/SITE  LOCATION   HIGH PRAIRIE ENERGY CO.
                                                                                               2.00 MMSCFD
                                                                                    -_-.-»««.„__.. --- «-__^-_.


                                                                                     NEAR CUT BANK, MT
                                                                                                                     TOOELE COUNTY
DETERMINATION MADE BY
PROCESSES SUBJECT
TO THIS PERMIT
                            EPA REGION VIII
                              (AGENCY)
                                                           JOHN DALE
                                                        (AGENCY CONTACT PERSON)
                                                                                               DATE °F PERHIT ISSUANCE-  09/05/80

                                                                                                              °F
                                                                                                   (PHONE)
                                      THROUGHPUT        POLLUTANT    EMISSION LIMITS
                                       CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION
                                                                                                                           4 BASIS
                                                                                                                           PCT EFF
INCINERATOR
NOTES -----------
4 YEAR PERMIT LIMIT
                                      2.00 HMSCFO
                                                           S02      65.0000 LB/H
                                                                            INCINERATION
                                                                                                                             BACT
                                                                                                                              0.00
<*) INDICATES DATUM WAS TRUNCATED FOP THIS TABLE.

PAGE G- 387
                                                                                        REVIEW
                                                     ID NUMBER MT-OOOI
                                                                                                          SOURCE TYPE CODE    5.5

-------
                                             APPENDIX --  DETAILED  SOURCE LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE—
                            PETROLEUM REFINING - AUXILIARY
                                                                                           66550.00  BPSD
COMPANY NAME/SITE LOCATION  HILL PETROLEUM
                            KROTZ SPRINGS TERMIN
                                                    KROTZ SPRINGS,  LA 70750
                                                                                                                 ST.  LANDRY PARISH
DETERMINATION IS BACT FOR A MODIFIED SOURCE.
PERMIT NO. (REGION FILE NO.) PSD-LA-286A
DETERMINATION MADE BY       EPA REGION VI
                             (AGENCY)
                          TOM  DIGGS
                       (AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE—  03/10/80
                                       ESTIMATED DATE OF START-UP--
                                       (2141-767-1594
                                           (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
     THROUGHPUT
      CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
,..  4 BASIS
. ..  PCT  EFF
HEATER


HEATER


TANKS, 11 EA


TAWS, 4 EA


TANKS, 2 EA


LOADING DOCK WASTEWATER
   146.00 MMBTU/H
    31.00 MMBTU/H
 80000.00 BBL
100000.00 BBL
150000.00 BBL
   VOC       0.0020 LB/MMBTU
                    EFFICIENT COMBUSTION

   VOC       0.0020 LB/MMBTU
                    EFFICIENT COMBUSTION

   VOC       2.4200 LB/H
                    DOUBLE SEALS

   VOC       2.5800 LB/H
                    DOUBLE SEALS

   VOC       7.3200 LB/H
                    DOUBLE SEALS

   VOC       3.8200 LB/H
                    MAINTENANCE PROGRAM
                                                                                            BACT
                                                                                            BACT
                                                                                            BACT
                                                                                            BACT
                                                                                            BACT
                                                                                                                             BACT
PAGE G- 388

-------
 (CONTINUED) HILL PETROLEUM
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT    EMISSION LIMITS                                   ... * BASIS
 EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
SEPARATOR
PUMP SEALS
VALVES & FLANGES
RELIEF VALVES
COMPRESSOR SEALS
                     VOC       0.3100 LB/H
                                      MAINTENANCE PROGRAM

                     VOC       0.6500 LB/H
                                      MAINTENANCE PROGRAM

                     VOC       7.7200 LB/H
                                      MAINTENANCE PROGRAM

                     VOC       1.2000 LB/H
                                      MAINTENANCE PROGRAM

                     VOC       0.1900 LB/H
                                      MAINTENANCE PROGRAM
                                                                     BACT


                                                                     BACT


                                                                     BACT


                                                                     BACT


                                                                     BACT
NOTES
(») INDICATES DATUM WAS TRUNCATED FOR THIS  TABLE.

PAGE G- 389
                                                                INITIAL REVIEW  POST STARTUP
                                                   REVIEW  STATUS;   04/01/1933
                                                      ID  NUMBER  LA-0027
                                                                                                           SOURCE TYPE CODE    5.5

-------
                                              APPENDIX  —  DETAILED SOURCE LISTING
                                                                                                                         05/22/198*



SOURCE  TYPE/SIZE—-          PETROLEUM REFINING -  AUXILIARY
                            — — — — — "••— — — •• — —«. — — _ _ _ —™ —_— _..______ — »^ ______ _^_ __ __,,__.^___ _„.. _..__.._________ — — — •._«.».____«.»_•_„_ _„ — •.____ ______

COMPANY NAME/SITE  LOCATION  HYDROCARBON RECYCLERS,  INC.                                       TULSA, OK
                            __ —	„ _«.___ ___.... ., _-._.. ____• _^,_. —_ — __ —_ — — — — «. _. — ,___ — —«, — -._ — — ___ «,_«__ _ —— _« __ — _ — — _ — — — ———_ — — — — — — _-.-.-, —-._._ — __ — »._—_

DETERMINATION  IS BACT  FOR  A MODIFIED  SOURCE.                                                    DATE OF PERMIT ISSUANCE—  05/14/82
PERMIT  NO. T81-15  & T82-101                                                                    ESTIMATED DATE OF START-UP—   1982
DETERMINATION  MADE BY        TULSA CITY-COUNTY HEALTH DEPT JIM VAN SANDT                       (91S)-744-1000
                              (AGENCY)                  CAGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                      THROUGHPUT        POLLUTANT   EMISSION LIMITS                                   ... & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF


ATMOS.  & VACUUM DISTIL. USED 01* 500000.00 GAL/YR
                                                           VOC      13.0000 T/YR
                                                                             INCIN.  IN OIL PREHEAT FURNACE                    98.00
DISTIL. OF CHLORINATED HC         150000.00 GAL/YR
                                                           VOC
                                                                             CLOSED  SYS-DISTIL.  UNIT i TANKAGE-2"H20 PRV      99.00


NOTES 	















                                                                                                       INITIAL REVIEW   POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                          REVIEW STATUS:   04/01/1983

PAGE G- 390                                           ID NUMBER  OK-0014                                    SOURCE TYPE CODE    5.5

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/22/198*



SOURCE TYPE/SIZE—         PETROLEUM  REFINING - AUXILIARY                                    50.00 MBPSD


COMPANY NAME/SITE LOCATION  INDEPENDENT REFIN.                                              WINNIE, TX
                                                                                                                  JEFFERSON  COUNTY


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF  PERMIT  ISSUANCE—   09/11/81
PERMIT NO. (REGION FILE NO.) PSD-TX-38S                                                        ESTIMATED DATE  OF  START-UP--
DETERMINATION MADE BY       EPA REGION VI                  TOM DIGGS                           (214)-767-159*
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION  LIMITS                                    ... 4 BASIS
TO THIS PERMIT                        CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF


HEATERS, 6                          96.50  MMBTU/H
                                                          NOX        0.1100 LB/MMBTU                                          NSPS
                                                                           LOW NOX BURNERS
REBOILER                            14.40  MMBTU/H
                                                          NOX        0.1100 LB/MM3TU                                          NSPS
                                                                           LOW NOX BURNERS


NOTES 	














                                                                                                      INITIAL  REVIEW POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR  THIS  TABLE.                                         REVIEW  STATUS: 04/01/1983

PAGE G- 391                                          ID NUMBER TX-0021                                     SOURCE TYPE  CODE     5.5

-------
                                             APPENDIX  — DETAILED  SOURCE  LISTING
                                                                                                                        05/22/1964



SOURCE TYPE/SIZE—-         PETROLEUM REFINING -  AUXILIARY                                   404.00  LT/D


COMPANY NAME/SITE LOCATION  KOCH REFINING CO.                                            ROSEMOUNT,  MM


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE  OF  PERMIT  ISSUANCE—  08/18/81
PERMIT NO. 106-81-1-19                                                                        ESTIMATED DATE  OF  START-UP—    1933
DETERMINATION MADE BY       MINNESOTA PCA                 AHTO NIEMIOJA                       (612)-296-7718
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION  LIMITS                                    ... 4  B4SIS
TO THIS PERMIT                         CAPACITY         EMITTED            CONTROL EQUIPMENT OR  PROCESS MODIFICATION   ... PCT EFF


CLAUS SULFUR RECOVERY UNIT *3       170.00 LT/D
                                                          SQZ      250.0000 PPM                                               NSPS
                                                                           TAIL GAS SCRUBBER                                 99.85


NOTES 	
THE EMISSION LIMIT IS BASED ON NSPS AVERAGING TIMES.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 392
                                                                                                      INITIAL REVIEW   POST STARTUP
ID NUMBER MN-0008
                                                     SOURCE TYPE CODE    5.5

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                         05/22/1984



SOURCE TYPE/SIZE—         PETROLEUM REFINING - AUXILIARY                                   404.00 LT/D


COMPANY NAME/SITE LOCATION  KOCH REFINING CO.                                            R05EMOUMT, MN
                           — — — — — — — ———-.-. — __ — — _—. — ^«,—,_ — ___»______«. —_ — _,^_»,_ —_ —___-, — _.__,____^__.__, — _w_—.____„.__,_.„,_— ^^, —_—,—_^_______.__^_w_-.__

DETERMINATION IS LAER FOR A NEW SOURCE.                                                        PATE OF  PERMIT  ISSUANCE—  01/25/83
PERMIT NO. 106A-83-I-23                                                                        ESTIMATED DATE  OF  START-UP—    19S3
DETERMINATION MADE BY       MINNESOTA PCA                  AHTO NIEMIOJA                       (612 J-E96-7718
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PKGNE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    . . . &  BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF


CLAUS SULFUR RECOVERY UNIT «4       234.00 LT/D
                                                           S02     150.0000 PPM
                                                                            TAIL GAS SCRUBBER                                 99.85


NOTES 	
THE EMISSION LIMIT IS BASED ON NSPS AVERAGING TIMES. A CONTINOUS EMISSION MONITORING SYSTEM WILL BE USED TO VERIFY  COMPLIANCE
OF COMBINED SRU 3 & 4 GASES AS A 30 D ROLLING AVERAGE AT 200 PPM.
(*> INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 393
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS;  04/19/1934
                                                      ID NUMBER MN-0008A
                                                                                                           SOURCE  TYPE  CODE    5.5

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE—         PETROLEUM REFINING - AUXILIARY                                 30000.00 BPSD


COMPANY NAME/SITE LOCATION  LOHGVEIW REFIN.                                               LONGVIEW, TX
                            5 KM SW POST OFFICE                                                                       GREGG COUNTY
                           — — — — — — — — — — — — — — — — — — — — — — — — — -• — — — — — — — — — — — — — — — — — » — — — — — _ — — — _ — — _ — — __ — — _». — _______„„__„____„_„„___»__,»______,_,___.._

DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE--  05/08/81
PERMIT NO. PSD-TX-364                                                                          ESTIMATED DATE OF START-UP--
DETERMINATION MADE BY       EPA REGION VI                  JOHN BUNYAK                         (2141-767-1594
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... t BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
FCC REGENERATOR
                                  15000.00 BBL/D
TURBINE, 3
HEATERS, 25
                                   6275.00 HP
                                     80.60 MMBTU/H
PM       10.6000 LB/H
                 ESP
S02     190.3000 LB/H
                 S REDUCTION CATAYLST
NOX      32.7000 LB/H
                 NONE
CO       79.5000 LB/H
                 HIGH TEMP REGENERATION

PM        0.0700 G/HP-H
                 REF. FUEL GAS
SQ2       0.1200 G/HP-H
                 REF. FUEL GAS
NOX       1.3000 G/HP-H
CO        0.4900 G/HP-H
                 EFFICIENT COMBUSTION

PM        0.0100 LB/MMBTU
                 FUEL GAS/LOW S OIL
S02       0.0270 LB/MJIBTU
                 FUEL GAS/LOW S OIL
                                                                                                                             BACT
                                                                                                                             75.00
                                                                                                                             BACT

                                                                                                                             BACT
BACT

BACT

BACT
NSPS


BACT

NSPS
PAGE G-

-------
                                                          NOX        0.1200  LB/MM8TU                                         BACT
                                                                            LOW NOX BURNERS
                                                          CO         0.0200  LB/MMBTU                                         BACT
                                                                            EFFICIENT COMBUSTION
PAGE S- 395

-------
(CONTINUED) LONGVEIW REFIN.
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
t BASIS
PCT EFF
BOILERS, 2
                                     74.00 MMBTU/H
SULFUR RECOVERY UNIT
                                     40.00 T/D
                     PM

                     S02

                     NOX

                     CO


                     S02
                                                                     0.0100  LB/MMBTU
                                                                            FUEL GAS
                                                                     0.0270  LB/MMBTU
                                                                            FUEL GAS
                                                                     0.1200  LB/MMBTU
                                                                            LOW  NOX BURNERS
                                                                     0.0200  LB/MV3TU
                                                                            EFFICIENT COMBUSTION
                                                                            3 STAGE CLAUS PLANT
                                                                     BACT

                                                                     BACT

                                                                     BACT

                                                                     BACT
                                                                                                                            NSPS
                                                                                                                            99.00
NOTES
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 396                                           ID NUMBER TX-0029
                                                                                                     INITIAL REVIEW  POST STARTUP
                                                                                        REVIEW STATUS:   0^/01/1933
                                                                     SOURCE  TYPE  CODE
                                                                                         5.5

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/32/1964
=r:r==r==="=======:-===================-:--=-===-_-=--_________-____^^



SOURCE TYPE/SIZE—         PETROLEUM REFINING -  AUXILIARY


COMPANY NAME/SITE LOCATION  MARATHON OIL CO.                                               ROBINSON,  IL
                                                                                                                   CRAWFORD COUNTY
                           — _— —	__	„	„	_	_,_ — — „	__«.____«._	_	..	„.	.		.	„.	™____

DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE  OF PERMIT ISSUANCE—  09/01/80
PERMIT NO. C 600503*                                                                           ESTIMATED DATE OF START-UP—   198Z
DETERMINATION MADE BY       ILLINOIS EPA                   CHRIS  ROHAINE                       (£17 }-78E-ail3
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PKGNE)



PROCESSES SUBJECT                     THROUGHPUT         POLLUTANT    EMISSION LIMITS                                   ... t BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
HEATERS
HEATER
                                    250.00 MHBTU/H  MAX
                                    £50.00 MKBTU/H  MAX
S02       1.0000 LB/MMBTU
                 H2S FUEL LIM .'0.10 GR/DSCF
NOX       0.3000 LB/MMBTU
                 LOU NOX BURNERS
PM        0.1000 LB/MMBTU

503       0.6000 LB/MMBTU
NOX       0.3000 LB/MMBTU
                 LOW NOX BURNERS
PM        0.1000 LB/MM3TU
NOTES 	
S02 EMISSION LIMIT TO BE MET WITH REFINERY GAS,  RESID.  OIL,  OR  ANY  COMBINATION.  H£S IN FUEL GAS LIMITED TO 0.1 GR/DSCF.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS  TABLE.

PAGE G- 397
                                           INITIAL REVIEW  POST STARTUP
                              REVIEW STATUS:  0
-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE—-         PETROLEUM REFINING - AUXILIARY


COMPANY NAME/SITE LOCATION  MARATHON OIL CO.                                            TEXAS CITY,  TX 77590
                            P.O. BOX 1191                                                                         GALVESTON COUNTY


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE  OF PERMIT ISSUANCE—  03/03/80
PERMIT NO. TX-241                                                                              ESTIMATED DATE OF START-UP--
DETERMINATION MADE BY       EPA REGION VI                  JOHN BUNYAK                         (214)-767-1594
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ...  & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ...  FCT EFF
HEATER, CRUDE
                                    175.00 MMBTU/H
                                                           NOX       36.7400  LB/H  NAT GAS
                                                                     0.2200  LB/MMBTU NAT  GAS
                                                                            LOU NOX BURN./LEA  FIRING
                                                           S02        4.3000  LB/H  NAT GAS
                                                                     0.0260  LB/MMBTU NAT  GAS
                                                                            <0.1  GR H2S/DSCF
                                                           NOX       52.5000  LB/H  FUEL OIL
                                                                     0.3000  LB/MM3TU FUEL OIL
                                                                            LOW NOX BURN/LEA FIRING
                                                           S02      115.8000  LB/H  FUEL OIL
                                                                     0.6600  LB/KMBTU FUEL OIL
                                                                            0.6'/.  S  FUEL OIL
                                    BACT


                                    NSPS


                                    BACT


                                    NSPS
NOTES 	
REPLACES AN EXISTING CRUDE HEATER FIRING REFINERY  GAS.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 39S
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS:  04/01/1933
                                                     ID NUMBER TX-0065
                                                                                                          SOURCE TYPE CODE
                                                                                                                              5.5

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/Z2/1984
SOURCE TYPE/SIZE —
                            PETROLEUM REFINING - AUXILIARY
                                                                                           70000.00 BBL/0
COMPANY NAME/SITE LOCATION  NATIONAL COOP.  REFIN.  ASSOC.
                                                                                         I1CPHERSON,  KS
                                                                                                                  MCPHERSON COUNTY
DETERMINATION IS BACT FOR A MODIFIED SOURCE.
PERMIT NO.
DETERMINATION MADE BY       EFA REGION VII
                             (AGENCY)
                      DANIEL RODRIGUEZ
                   (AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE--  07/17/81
                                       ESTIMATED DATE OF START-UP—
                                       (8161-374-6525
                                           (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
 THROUGHPUT
  CAPACITY
POLLUTANT    EMISSION LIMITS                                   ... & BASIS
 EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
PROCESS HEATER, UNIT HF-009
PROCESS HEATER, UNIT HF-010
PROCESS HEATER, UNIT HP-012
64.00 MMBTU/H


64.00 MMBTU/H


33.90 MMBTU/H
   NOX       0.1500 LB/MMBTU MAX
                    LOW EXCESS AIR

   NOX       0.1500 LB/MMBTU MAX
                    LOW EXCESS AIR

   NOX       0.1500 LB/MMBTU MAX
                    LOW EXCESS AIR
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
NOTES 	
REFINERY BEING MODIFIED TO ALLOW PROCESSING  OF  HIGH  SULFUR  CRUDES  (SCC  PROJECT).  CAPACITY  TO BE  INCREASED FROM 57000 TO 70000
EBL/D. SOURCE SIZE IS PEFINERY CAPACITY.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS  TABLE.

PAGE G- 399
                                                                 INITIAL REVIEW  POST STARTUP
                                                    REVIEW STATUS:   04/01/1933
                                                      ID NUMBER KS-0003
                                                                                                           SOURCE  TYPE  CODE     5.5

-------
                                             APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                         05/22/1984




SOURCE TYPE/SIZE—          PETROLEUM REFINING - AUXILIARY                                     35.00 MBPSD
                            — — — — -. — — —— — — — »—— — ———-.— — — — — — _ — —-_— — — __ _ _ __ — _<_.___ — _,- «. ___ __«____«_ „.._ _.. _ _ »_ _• — _•• -.«_.._____ — •.!—•—«— — —••—«• — — ___ _

COMPANY NAME/SITE LOCATION   NEDERLAND PROCESSING CO.                                      NEOERLAND, TX 77627
                             P.O. BOX 1567                                                                          JEFFERSON COUNTY
                            — — — — — — — — — — — — — —— — — — — — — — — — — —— — — — — — — — — — — — — — — — —— — — — — — ~ —— •. — — — — — — «•. — — •— — — »- — ——. — — »•. — — —. — — •. — ..._^ — «.™™«__..^_._.___.,—_»___,»_._,,.


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE--  10/31/80
PERMIT NO. TX-262                                                                              ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY        EPA REGION VI                  JOHN BUNYAK                         (214)-767-1594
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)




PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ...  4 BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT  OR PROCESS MODIFICATION  ...  PCT EFF
VACUUM UNIT FURNACE
                                    150.00 MMBTU/H
                                                           PM        7.9000 LB/H OIL
                                                                     0.0530 LB/MMBTU OIL
                                                                            LIQUID OR GASEOUS FUEL
                                                           S02      70.0000 LB/H OIL
                                                                     0.4670 LB/MMBTU OIL
                                                                            0.42X S OIL
                                                           NOX      45.0000 LB/H OIL
                                                                     0.3000 LB/MMBTU OIL
                                                                            LEA FIRING
                                                           CO        5.5000 LB/H OIL
                                                                     0.0370 LB/MMBTU OIL
                                                                            COMBUSTION CONTROLS
                                                           VOC       1.1000 LB/H OIL
                                                                     0.0070 LB/MMBTU OIL
                                                           PM        2.0000 L6/H GAS
                                                                     0.0130 LB/W13TU GAS
                                                                            LIQUID 03 GASEOUS FUEL
                                                           S02       3.5000 LB/H GAS
                                                                     0.0230 LB/M?:BTU GAS
                                                                            O.T/. GR H2S/DSCF
                                                           NOX      18.0000 LB/H GAS
BACT


BACT


BACT


BACT


LAER

BACT


NSPS


BACT
PAGE G- 400

-------
                                                                      0.1200  L8/KMBTU GAS
                                                                             LEA  FIRING
                                                           CO         2.3000  LB/H GAS                                         BACT
                                                                      0.0150  LB/MHBTU GAS
                                                                             COMBUSTION CONTROLS
                                                           VOC        0.4000  LB/H GAS                                         BACT
                                                                      0.0070  LB/MKSTU GAS
PAGE G- 401

-------
 (CONTINUED) NEDERLAND  PROCESSING CO.
PROCESSES SUBJECT THROUGHPUT POLLUTANT
TO THIS PERMIT CAPACITY EMITTED
FCCU REGEN
PM


S02

NOX

CO


voc
ISOSTRIPPER REBOILER 90.00 MMBTU/H
PM


S02


NOX


CO


voc

PM


S02


NOX


CO

EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

8.4000 LB/H
1.0000 LB/MLB COKE
ESP
42.7000 LB/H
S REDUCTION CATALYST
31.5000 LB/H
LEA FIRING
73.5000 LB/H
500.0000 PPMV, LESS THAN
COMBUSTION CONTROL
7.9000 LB/H

4.7000 LB/H OIL
0.0520 LB--W.BTU OIL
LIQUID OR GASEOUS FUEL
42.0000 LB/H OIL
0.4670 LB/MIIBTU OIL
0.42X S OIL
27.0000 LB/H OIL
0.3000 LB/MMBTU OIL
LEA FIRIKS
3.3000 LB/H OIL
0.0370 LB/KH3TU OIL
COI3USTION CONTROLS
0.7000 LB/H OIL
O.OCSO LB/ M^STU OIL
1.2000 LB/H GAS
0.0130 LB/Mri3TU GAS
LIQUID OR GASEOUS FUEL
2.1000 LB/H GAS
0.0230 LB/MM3TU GAS
0.1X GR H2S/DSCF
10.8000 LB/H GAS
0.1200 LB/MM3TU GAS
LEA FIRIN3
1.4000 LB/H GAS
0.0160 LB/MMBTU GAS
... li BASIS
... PCT EFF

NSPS

95.00
BACT
75.00
BACT

NSPS


BACT

BACT


BACT


BACT


BACT


BACT

BACT


NSPS


BACT


BACT

PAGE G- 402

-------
(CONTINUED) NEDERLAND PROCESSING CO.
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
...  t  BASIS
...  PCT  EFF
SULFUR PLANT
FLARE
                                      2.70 MMBTU/H GAS
BOILER
                                    170.00 MMBTU/H OIL
                     S02       2.2000 LB/H
                                      SCOT TAIL GAS TREAT.
                     NOX •      0.3000 LB/H
                               0.1200 LB/MMBTU
                                      NONE

                     PM               TRACE
                                      SMOKELESS OPERATION
                     S02              NEGLIGIBLE
                                      NOME
                     NOX              TRACE
                                      SMOKELESS/STEAM INJECTION
                     CO               TRACE
                                      SMOKELESS OPERATION

                     PM        8.9000 LB/H OIL
                               0.0520 LB/MMBTU OIL
                                      LIQUID OR GASEOUS FUEL
                     S02      79.3000 LB/H OIL
                               0.4670 LB/MM3TU OIL
                                      0.42X S FUEL
                     NOX      51.0000 LB/H OIL
                               0.3000 LB/HM3TU OIL
                                      LEA FIRING
                     CO        6.2000 LB/H OIL
                               0.0360 ,LB/t',:;3TU OIL
                                      COMBUSTION CONTROLS
                     VOC       1.2000 LB/H OIL
                               0.0070 LB/Mr'3TU OIL
                     PM        2.3000 LB/H GiS
                               0.0140 LB/MM3TU GAS
                                      LIQUID OR GASEOUS FUEL
                     S02       4.2000 LB/H GAS
                               O.OC50 LB/MMBTU GAS
                                      0.1X GR H2S/DSCF
                     NOX      20.4COO LB/H G^S
                               0.1200 LB/MMBTU GAS
                                                                                                                             BACT
                                                                                                                             95.00
                                                                                                                             BACT
                                                                     BACT

                                                                     BACT

                                                                     BACT

                                                                     BACT


                                                                     BACT


                                                                     BACT


                                                                     BACT


                                                                     BACT


                                                                     BACT

                                                                     BACT


                                                                     BACT


                                                                     BACT
PAGE G- 404

-------
                                                                             COMBUSTION CONTROLS
                                                           CO         2.6000  LB/H  GAS                                         BACT
                                                                      0.0150  IB/MMBTU GAS
                                                                             COMBUSTION CONTROL
                                                           VOC        0.5000  LB/H  GAS                                         BACT
                                                                      0.0070  LB/MTTBTU GAS
PAGE G- 405

-------
(CONTINUED)  NEDERLAND PROCESSING CO.
PROCESSES SUBJECT
TO THIS PERMIT
VALVES -

VALVES -

VALVES -

FLANGES,

- GAS VAPOR, 396

- LIGHT LIQUID, 268

- HEAVY LIQUID, 357

3650

THROUGHPUT POLLUTANT
CAPACITY EMITTED

VOC

VOC

VOC

VOC
EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS

2.1000

0.9000

0.2000

2.1000

LB/H

LB/H

LB/H

LB/H
... & BASIS
MODIFICATION ... PCT EFF

BACT

BACT

BACT

BACT
OIL/WATER SEP

PUMPS —

PUMPS —

COOLING

STORAGE


LIGHT LIQUID, 58

HEAVY LIQUID, 7

TCHER

TANKS, 6

VOC

VOC

VOC

VOC
55.00 MBBL EA
VOC
3.6000

2.0000

0.3000

3.6000

7.8000
LB/H

LB/H

LB/H

LB/H

LB/H TOTAL
BACT

BACT
.
BACT

BACT

BACT
                                                                           EXTERNAL FLOATING ROOFS
NOTES
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.


PAGE G- 406
                                                                                                     INITIAL REVIEW  POST STARTUP
                                                                                        REVIEW STATUS;  0^/01/1933
ID NUMBER TX-0060
                                                     SOURCE  TYPE CODE
                                                                        5.5

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984
 SOURCE  TYPE/SIZE---
                            PETROLEUM REFINING - AUXILIARY
 COMPANY NAME/SITE  LOCATION  PETRACO VALLEY OIL * REFINING CO.
                            1201 DAIRY ASHFORD, SUITE 150
                                   HOUSTON, TX
                                                                                                                    CAMERON COUNTY
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT NO. TX-236
DETERMINATION HADE BY       EPA REGION VI
                             (AGENCY)
   JOHN BUNYAK
(AGENCY CONTACT PERSON)
DATE OF PERMIT ISSUANCE—  10/15/80
ESTIMATED DATE OF START-UP--
    1-767-1594
    (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
HEATER, CRUDE CHARGE














HEATER, VACUUM CHARGE





THROUGHPUT POLLUTANT
CAPACITY EMITTED
427.00 MM3TU/H
PM


S02


NOX


VCC


CO

£19.00 MMBTU/H
PM


S02

EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

3.2000 LB/H
0.0070 LB/MM3TU
GAS FIRED, F.G. 02 CONTROL
6.6000 LB/H
0.0100 LB/MMBTU
LOW S GAS (0.1 GR H2S/DSCF )
51.3000 LB/H
0.1200 LB/MMBTU
LEA FIRING, F.G. 02 CONTRL
0.8000 LB/H
0.0020 LB/MMBTU
F.G. 02 CONTROL
4.6000 LB/H
0.0100 LB/MUBTU
F.G. 02 CONTROL
1.7000 LB/H
0.0070 LB/MM3TU
GAS FIRED, F.G. 02 CONTRL.
3.5000 LB/H
0.0200 LB/MMBTU
... 8 BASIS
... PCT EFF

BACT


NSFS


BACT


BACT


BACT


BACT


NSPS

PAGE G- 407

-------
                                                                            LOW S GAS (0.1 GR H2S/DSCF)
                                                          NOX      26.2000  LB/H                                             BACT
                                                                    0.1200  LB/MMBTU
                                                                            LEA FIRING, F.G. 02 CONTRL
                                                          VOC       0.4000  LB/H                                             BACT
                                                                    0.0020  LB/MMBTU
                                                                            F.G. 02 CONTROL
                                                          CO        2.3000  LB/H                                             BACT
                                                                    0.0100  LB/MMBTU
                                                                            F.G. 02 CONTROL
PAGE G- 403

-------
 (CONTINUED) PETRACO VALLEY OIL ft REFINING CO.
PROCESSES SUBJECT THROUGHPUT POLLUTANT
TO THIS PERMIT CAPACITY EMITTED
COKER HEATER 401.00 MMBTU/H
PM


soa


NOX


VOC


CO


FCCU REGENERATOR 24.90 MBBL/D
PM


S02

NOX

VOC

CO


HEATER, HYDROHEATER FEED 147.00 MMBTU/H
PM


so2


NOX

EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

3.0000 LB/H
0.0070 LB/MMBTU
GAS FIRED, F.G. 0.°. CONTRL
6.7000 LB/H
0.0200 LB/MMBTU
LOW S GAS, (0.1 6R H2S/OSCF )
48.1000 LB/H
0.1200 LB/MH3TU
LEA FIRING, F.G 02 CONTRL
0.9000 LB/H
0.0020 LB/MMBTU
F.G. 02 CONTROL
4.7000 LB/H
0.0100 LB/MMBTU
F.G. OZ CONTROL

16.7000 LB/H
1.0000 LB/MLB COKE
ESP
116.9000 LB/H
S REDUCTION CATALYST
39.3000 LB/H
LEA FIRING, F.G. 02 CONTROL
12.7000 LB/H
F.G. 02 CONTROL
61.2000 LB/H
O.CSOO 7. BY VOL.
F.G. 02 CONTROL

1.1000 LB/H
0.0070 LB/."MBTU
GAS FIRED, F.G. 02 CONTRL
2.6000 LB/H
0.0200 LB/MM5TU
LOU S GAS (0.1 GR H2S/DSCF)
17.6000 LB/H
0.1200 LB/MMBTU
... & BASIS
... PCT EFF

BACT


BACT


BACT


BACT


BACT



NSPS

75.00
BACT
85.00
BACT

BACT

NSPS



BACT


NSPS


BACT

PAGE G- 409

-------
                                                                           LEA FIRING, F.G. 02 CONTROL
                                                          VOC.      0.3000 LB/H                                             BACT
                                                                    0.0020 LB/MM3TU
                                                                           F.. 02 CONTROL
                                                          CO        1.7000 LB/H                                             BACT
                                                                    0.0100 LB/HHBTU
                                                                           F.. 02 CONTROL
PAGE G- 410

-------
 (CONTINUED) PETRACO VALLEY OIL fc REFINING CO.
PROCESSES SUBJECT
TO THIS PERMIT
HEATER, HYDROCRACKER















REGENERATOR, PLATFORMER CAT.










HEATER, PLATFORM FEED










THROUGHPUT POLLUTANT
CAPACITY EMITTED
352.00 MMBTU/H
PM


S02


NOX


VOC


CO



PM

S02

NOX

VOC

CO

932.00 MttBTU/H
PM


S02


NOX


VOC
EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

2.7000 LB/H
0.0070 LB/MMBTU
GAS FIRED, F.G. 02 CONTRL
6.1000 LB/H
0.0200 LB/HMBTU
LOW S GAS, 0.1 GR H2S/OSCF
42.3000 LB/H
0.1£00 LB/MMBTU
LEA FIRING, F.G. 02 CONTRL
0.8000 LB/H
0.0020 LB/KMBTU
F.G. 02 CONTROL
4.1000 LB/H
0.0100 LB/MMBTU
F.G. 02 CONTROL

TRACE
NONE
0.1000 LB/H
NOS'E
TRACE
NOS'E
TRACE
NOME
TRACE
NOME

53.2000 LB/H
0.0070 LB/MM3TU
OIL FIRED, F.G. 02 CONTRL
570.9000 LB/H
O.OCCO LB/HMSTU
LOW S GAS, 0.7X S/LB
321,9000 LB/H
0.1200 LB/MM3TU
LEA FIRING, F.G. 02 CONTRL
5.3000 LE/H
:.. & BASIS
. . . PCT EFF

BACT


NSPS


BACT


BACT


BACT



BACT

BACT

BACT

BACT

BACT


BACT


BACT


BACT


BACT
PAGE G-

-------
                                                                     0.0020  LB/MHBTU
                                                                            F.6.  02 CONTROL
                                                           CO        86.8000  LB/H                                             BACT
                                                                     0.0100  LB/HMBTU
                                                                            F.6.  02 CONTROLS
PAGE G- 412

-------
 (CONTINUED) PETRACO VALLEY OIL 4 REFINING CO.
PROCESSES SUBJECT
TO THIS PERMIT
HEATER, PENEX ISOMER FEED














INCIN., SULFUR PLANT















HEATER, HF ALK ISOSTRIPPER REBO*





THROUGHPUT POLLUTANT
CAPACITY EMITTED
15.00 MMBTU/H
PM


S02


NOX


VOC

CO


48.00 MMBTU/H
PM


S02


NOX


VOC


CO


233.00 MMBTU/H
PM


S02

EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

0.1000 LB/H
0.0070 LB/MMBTU
6AS FIRED, F.G. 02 CONTROL
0.3000 LB/H
0.0200 LB/HMBTU
LOW S GAS, 0.1 GR H2S/DSCF
1.7000 LB/H
0.1200 LB/MMBTU
LEA FIRING, F.S. 02 CONTRL
TRACE
F.G. 02 CONTROL
0.2000 LB/H
0.0100 LB/MI1BTU
F.G. 02 CONTROL

0.4000 LB/H
0.0080 LB/MMBTU
NOME
26.0000 LB/H
0.0200 •/. BY VOL.
SULFUR PLANT, SULFUR RECOVERY
67.4000 LB/H
1.4000 LB/MMBTU
LEA FIRING, F.G. 02 CONTRL
0.1000 LB/H
0.0020 LB/rtfBTU
F.G. 02 CONTROL
0.4000 LB/H
0.0080 LB/MMBTU
F.G. 02 CONTROL

1.7000 LB/H
0.0070 LB/MMBTU
GAS FIRED, F.G. 02 CONTRL
4.0000 LB/H
0.0200 LB/MM3TU
...» BASIS
. . . PCT EFF

BACT


NSPS


BACT


BACT

BACT



BACT


NSPS

99.90
BACT


BACT


BACT



BACT


NSPS

                                                                            LOW  S  645,  0.1  GR  H2S/DSCF
PAGE G- 413

-------
                                                           NOX      28.0000 LB/H                                             BACT
                                                                     0.1EOO LB/MMBTU
                                                                            LEA FIRING,  F.G.  02 COMTRL
                                                           VOC       0.5000 LB/H                                             BACT
                                                                     0.0020 LB/MMBTU
                                                                            F.G. 02 CONTROLS
                                                           CO        2.7000 LB/H                                             BACT
                                                                     0.0100 LB/MMBTU
                                                                            F.G. 02 CONTROL
PAGE G-

-------
 (CONTINUED)  PETRACO VALLEY OIL & REFINING CO.
PHOCE55ES SUBJECT THROUGHPUT POLLUTANT
TO THIS PERMIT CAPACITY . EMITTED
HEATER, BUTAMER ISOMER 12.00 MMBTU/H
PM


S02


NOX


VOC

CO


FLARE
S02

NOX

VOC

CO

PM

BOILER 255.00 MMBTU/H
PM


S02


NOX


VOC

EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

0.1000 LB/H
0.0070 LB/MMBTU
GAS FIRED, F.G. O2 CONTROL
0.2000 LB/H
0.0200 LB/MMBTU
LOW S GAS, 0.1 GR H2S/OSCF
1.4000 LB/H
0.1200 LB/MMBTU
LEA FIRING, F.G. 02 CCNTRL
TRACE
F.G. 02 CONTROL
0.1000 LB/H
0.0100 LB/MMBTU
F.G. 02 CONTROL

112.1000 LB/H
NONE
78.8000 LB/H
STEAM INJECTION
3.3000 LB/H
STEAM INJECTION
17.8000 LB/H
STEAM INJECTION
0.0000 LB/H
STEAM INJECTION

1.9000 LB/H
0.0070 LB/MMBTU
GAS FIRED, F.G. 02 CONTRL
3.4000 LB/H
0.0100 LB/mSTU
LOW S GiS, 0.1 G3 H2S/DSCF
31.7000 LB/H
0.1200 LB/r;rBTU
LEA FIRING, F.G. 02 OT4TROL
0.4000 LB/H
0.0020 LB/MMBTU
... t BASIS
... PCT EFF

BACT


BACT


BACT


BACT

BACT





BACT

BACT

BACT

BACT


BACT


NSPS


BACT


BACT

PAGE G- 415

-------
                                                                            F.G. 02 CONTROL
                                                           CO        2.3000 LB/H                                             BACT
                                                                     0.0100 LB/MMBTU
                                                                            F.G. 02 CONTROL
PAGE 6- 
-------
 (CONTINUED)  PETRACO VALLEY OIL fc REFINING CO.
PROCESSES SUBJECT THROUGHPUT POLLUTANT
TO THIS PERMIT CAPACITY EMITTED
HEATER, OIL 163.00 MMBTU/H
PM


S02


NOX


VOC


CO


HEATER, SCOT UNIT FEED 5.00 MMBTU/H
PM

so2


NOX


VOC

CO


EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

1.8000 LB/H
0.0070 LB/MMBTU
GAS FIRED, F.6. 02 CONTRL
2.8000 LB/H
0.0100 LB/MMBTU
LOW S GAS, 0.1 GR H2S/DSCF
19.6000 LB/H
0.1200 LB/MMBTU
LEA FIRING, F.6. 02 CONTROL
0.4000 LB/H
0.0020 LB/MMBTU
F.G. 02 CONTROL
1.9000 LB/H
0.0100 LB/MMBTU
F.G. 02 CONTROL

TRACE
NOME
0.1000 LB/H
0.0100 LB/MMBTU
NONE
0.6000 LB/H
0.1200 LB/MMBTU
NONE
TRACE
NONE
0.1000 LB/H
0.0100 LB/MMBTU
NONE
... 4 BASIS
... FCT EFF

BACT


NSPS


BACT


BACT


BACT



BACT

BACT


BACT


BACT

BACT


NOTES
(*) INDICATES DATUM WAS TRUNCATED  FOR  THIS TABLE.

PAGE G- 417
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS:  0*/01/1983
                                                     ID NUMBER TX-0073
                                                                                                          SOURCE TYPE CODE
                                                                                                                              5.5

-------
                                             APPENDIX —  DETAILED SOURCE LISTING
                                                                                                                        05/23/1984




SOURCE TYPE/SIZE—         PETROLEUM REFINING - AUXILIARY                                130000.00 BPSD
                           __	_	— „ —	—	— —	—	_______	_ — ___-,	— ,-.	— — —	— — _	— _	—— —	_______	______	— —	— —


COMPANY NAME/SITE LOCATION  PHILLIPS PETROLEUM CO.                                           BORGER, TX
                            BORGER REF NGL CONTR.                                                                 HUTCHINSON COUNTY
                           — — «... — — — —— — —_ __ — — _ _________ ___—. ________.-___->____ __ — — — — —•.. — — — — — — —— — ————• — — —— — — — — ——. — — —••••- — — — —— — —— — — — — — — ——— —


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE—  10/15/81
PERMIT NO.  PSD-TX-102M-1                                                                       ESTIMATED DATE OF START-UP—
DETERMINATION MADE BY       EPA REGION VI                 JOHN BUNYAK                         (214J-767-1594
                             (AGENCY)                  (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT       POLLUTANT   EMISSION LIMITS                                   ...  4 BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT  OR PROCESS MODIFICATION  ...  PCT EFF
I.C. ENGINE, Z
                                    650.00 HP EA
TURBINE, 2
                                   3000.00 HP EA
                                                           S02
                                                           NOX
                                                           VOC
                                                           CO
                                                           PM
                                                           S02
                                                           NOX
0.0320
0.8000

0.1360
0.4000

0.0036
0.0070

0.0170
0.0340

0.0100
0.0700

0.0320
0.8000

0.1360
0.4000
LB/MMBTU GAS
LB/nr'BTU OIL
0.7X S IN OIL
LB/MMBTU GAS
LB/MM3TU OIL
02 MONITORING
LB/MMBTU GAS
LB/MMBTU OIL
02 MONITORING
LB/MMBTU GAS
LB/MM3TU OIL
02 MONITORING
LB/MMBTU GAS
LB/MC3TU OIL

LB/MMBTU GAS
LB/MMBTU OIL
0.7X S IN OIL
LB/MMBTU GAS
LB/MMBTU OIL
02 MONITORING
PAGE G- 418

-------
                                                           VOC       0.0036 LB/MMBTU GAS
                                                                     0.0070 LB/MMBTU OIL
                                                                            02 MONITORING
                                                           CO        0.0170 LB/MMBTU GAS
                                                                     0.03-+0 LB/MMBTU OIL
                                                                            02 MONITORING
                                                           PM        0.0100 LB/MMBTU GAS
                                                                     0.0700 LB/MMBTU OIL
PAGE G-

-------
(CONTINUED) PHILLIPS PETROLEUM CO.
PROCESSES SUBJECT THROUGHPUT
TO THIS PERMIT CAPACITY
HEATERS, 4 32.00 MMBTU/H










CRUDE OIL TANKS, 3 200.00 MBBL


FUGITIVE EMISSIONS


CO BOILERS, 2 370.00 MMBTU/H









I.C. COMPRESSOR 720.00 HP







<*> INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.
POLLUTAW
EMITTED

S02

NOX

VOC

CO

PM


VOC


VOC


S02
NOX

VOC

CO

PM


S02

NOX
VOC
CO
PM


f EMISSION LIMITS . . . i BASIS
CONTROL EQUIPMENT OR PROCESS MODIFICATION . . . PCT EFF

0.0320 LB/MMBTU
GAS AS FUEL
0.1360 LB/MMBTU
02 MONITORING
0.0036 LB/M;:BTU
02 MONITORING
0.0170 LB/MMBTU
02 MONITORING
0.0100 LB/MM3TU
GAS AS FUEL

1.8300 T/YR EA
EPA EQUIV. STAND t MAINT. PROG

140.0000 T/YR
EPA EQUIV. STAND & KAINT . PROG

0.1000 LB/Mr.BTU
1.9000 LB/MNBTU
02 MONITORING
0.0014 L3/MM3TU
02 MONITORING
0.0170 LB/NI-STU
02 MONITORING
0.3100 LB/MM3TU
G4S AS FUEL

0.1000 G/HP-H
GAS AS FUEL
10.9000 G/HP-H
4.4COQ G/HP-H
1.3900 G/HP-H
0.0200 G/HP-H
GAS AS FUEL
INITIAL REVIEW POST STARTUP
REVIEW STATUS; 04/01/1933
PAGE G- 420
                                                     ID NUMBER TX-OOS2
                                                                                                          SOURCE TYPE CODE
                                                                                                                              5.5

-------
 NATURAL SAS FIRED
(*_!_I^ICATES_DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEW STATUS:NIo"*/Ol!a9S3W  ***




PAGE G- 421                                           ID ^if«BER TX-0052
                                                                                                             SOURCE  TYPE  CODE    5.5

-------
                                             APPENDIX -- DETAILED SOURCE LISTING
                                                                                                                        05/22/198"+




SOURCE TYPE/SIZE---         PETROLEUM REFINING - AUXILIARY                                 10000.00 BBL/D
                           _.	— —	—	— —	— — —	— — —	— —	—	—	—	— — — —	— — —	— — — —	-._-. — _ — _ — —. — — — -. — — — — — —

COMPANY NAME/SITE LOCATION  PROCESS REFIN. CO.                                         BAKERSFIELD, CA
                           	«_«„«-__-_--—-_-_—	«.„_„___--_•____.-._-.—————--———----------------—-------—----—-----—--—---—---—

DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE--  09/19/79
PERMIT HO. SJ-78-27                                                                            ESTIMATED DATE OF START-UP—
DETERMINATION MADE BY       EPA REGION IX                  MATT HABER                          (4151-974-8053
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    < PHCh'E )



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... * BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF


VACUUM HEATER                        £5.00 MMBTU/H
                                                           NOX       0.2700 LB/MMBTU
                                                                            LOW NOX BURNERS                                  35.00
CRUDE HEATER                         20.00 MMBTU/H
                                                           NOX       0.2700 LB/MM3TU
                                                                            LOU NOX BURNERS                                  35.00
BOILER, 2 EA                          4.31 MH3TU/H
                                                           NOX       0.2700 LB/HMBTU
                                                                            LOW NOX BURNERS                                  35.00



NOTES 	













                                                                                                      INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED  FOS THIS TABLE.                                        REVIEW STATUS^__04/01/19S3____04/04/19S4_

PAGE~G-~422ID NUMBER CA-0013                                    SOUPCE TYP5 CODE    5.5

-------
                                              APPENDIX — DETAILED  SOURCE LISTING
                                                                                                                           05/22/1984
 SOURCE TYPE/SIZE—         PETROLEUM REFINING - AUXILIARY                                     50.00 HBPSO
                                                                           -
 COMPANY NAME/SITE LOCATION  PROVIDENT ENERGY CO.
                                                                                              MOBILE, AZ
                                                                                                                        E—   03/03/80
 DETERMINATION MADE BY       EPA REGION IX                  JIM HANSON                           fS^-S-S^S °* *™™P"
                              (AGENCY)                   (AGENCY CONTACT  PERSON)                     (FHCNE)
                                      : = r:rr-=-r = rrr=:= = = zr = z = r: = ==rmr:sr;- = r=r = = ^zrr=:rr=rr=r:rr = r^ = rr-=:r7:^:rr-z- — -	----	___	_..„_	
                                       THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                     ..  & BASIS
                ._	           CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ] !.' PCT  EFF
                     — — — — ,.__-.___„_  ___	_	_	__	, —_ _<-	—	^:	__	_^_	^	
                                                                                           — — _ »_ _ „._- — — — — -• — — — -. — — — __-_____^.__-,_—11_^.__—,__,___
 BOILER  & HEATER
                                                            NOX       0.4300 LB/tlMBTU  2H  AV
                                                                             LOW NOX BURNERS
                                                            S02
 CLAUS SULFUR  RECOVERY UNIT                                                  FUEL  LIM^S-.IGR/DSCF.S-.^XWT
                                                            H2S
 FCC UNIT i CATALYIST REGEN.                                                  SC°T  TAIL GAS ™ir
                                                            PM        1.0000 LB/MLB COKE  BURNED
                                                                             3 STAGE CATALYST SEP.  4 ESP
                                                            CO
                                                                             CO BOILER
                                                            S02
                                                                             FUEL  LIM:H£S-.1GR/DSCF,S-.1XWT
NOTES
COVERED DILUTES SUPER.™. WPCH RECOVERY OH  LIGHT GASOLINE  TANKS,  WD DOUBLE SEALED fSjATITO Mwl^ mlrBER eASOLIMt T
«^f™!!J™B^8™^*I!L = «=^LI^!:	          REVIEW STATUS^SJ/o'l/mf  "** *™™
PAGE G" 4"                                           ID Nl^BER  AZ-0001                                     SOUScrTYFrcODE==:=T5

-------
                                             APPENDIX -- DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE—-         PETROLEUM REFINING - AUXILIARY                                   100.00 MBPSO


COMPANY NAME/SITE LOCATION  SABER REFIN.                                            CORPUS CHRISTI, TX
                            6560 UPRIVER ROAD                                                                        NEUCES COUNTY


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE—  05/08/81
PERMIT NO. (REGION FILE NO.) PSD-TX-324                                                        ESTIMATED DATE OF START-UP--
DETERMINATION MADE BY       EPA REGION VI                  JOHN BUNYAK                         (214)-767-1594
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   . .. « BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ... PCT EFF
HEATERS, 5
365.00 MMSTU/H
FURNACES, 5
REBOILERS, 2
178.00 MMBTU/H
                                    158.00 MMBTU/H
PM        0.0100 LB/MMBTU
                 REF. FIELD GAS
S02       0.0140 LB/MMBTU
                 FIRE REFINERY FLUE GAS
NOX       0.1EOO LB/rr,5TU
                 IQ'A NOX BURNERS
CO        0.0160 LB/MMBTU
                 EFFICIENT COMBUSTION

PM        0.0100 LB/Mt'.BTU
                 REF. FUEL GAS
S02       0.0140 LB/f1!'3TU
                 REF. FUEL GAS
NOX       0.1200 LB/MMBTU
                 LOW NOX BURNERS
CO        0.0160 LB/71M3TU
                 EFFICIENT COMBUSTION

PM        0.0100 LB/MMBTU
                 REF. FUEL GAS
S02       0.0140 LB/MMBTU
BACT

NSPS

BACT

BACT


BACT

NSPS

B4CT

BiCT


BACT

NSPS
PAGE G- 424

-------
                                                                            REF.  FUEL GAS
                                                           NOX       0.1200 LB/HMBTU                                         BACT
                                                                            LCM NOX BURNERS
                                                           CO        0.0160 LB/MKBTU                                         BACT
                                                                            EFFICIENT COMBUSTION
PAGE G-

-------
(CONTINUED) SABER REFIH.
PROCESSES SUBJECT
TO THIS PERMIT
REFORMERS, 2








HEAVY OIL CRACKING UNIT








THROUGHPUT POLLUTANT
CAPACITY EMITTED
356.00 MMBTU/H
PM

S02

NOX

CO

46500.00 BPSD
PM

S02

NOX

CO

EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

0.0100 LB/MHBTU
REF. FUEL GAS
0.0140 LB/KMBTU
FIRE REF. FUEL GAS
0.1200 LB/HMBTU
LOW NOX BURNERS
0.0160 LB/MM3TU
EFFICIENT COMBUSTION

5.6000 LB/H
3-STAGE CYCLONE
178.0000 PPM
FLUE GAS DESULFURIZATION
203.0000 LB/H
KO CONTROLS AVAILABLE
178.0000 PPM
WASTE HEAT BOILER
...& BASIS
... FCT EFF

BACT

NSPS

BACT

BACT


BACT

NSPS
93.20
EACT

NSPS

NOTES 	
H2S CONTENT OF FLUE GAS WILL BE LIMITED TO 0.054  GRAINS/DSCF.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.


PASE G- 426
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS;  04/01/1933
                                                     ID NUMBER TX-0041
                                                                                                          SCtTCE TYPE CODE
                                                                                                                              5.5

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984
= ~ = = = = -~ = = := = = - = :: = :: = = = = :::: = = = = = = = = = = = = = = = = === = = = - = = = = = r = = r: = = = = =:r = = = = r = ===r=: = = = r = = = = = = r = ri: = = r = = = rr = = = =: = r=r = = = = = = rsr = = = = = = = = = = =r = = r = = =


SOURCE TYPE/SIZE—         PETROLEUM REFINING - AUXILIARY                                    67.00 MBPSD


COMPANY NAME/SITE LOCATION  SIGMORE REFIN. CO.                                         SAN ANTONIO, TX 78220
                            P.O. BOX 20267                                                                         LIVE OAK COUNTY


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE—  12/10/80
PERMIT HO. (REGION FILE NO.) PSD-TX-331                                                        ESTIMATED DATE OF START-UP--
DETERMINATION MADE BY       EFA REGION VI                  JOHN BUNYAK                         (214 J-767-1594
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... S BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
HEATER, SI CRUDE
                                     59.50 HMBTU/H
HEATER, LUBE CRUDE
FCCU REGENERATOR
                                     10.80 MM3TU/H
                                     40.00 MBPSD
PM        2.7500 LB/H
                 EFFICIENT COMBUSTION
S02      22.1800 LB/H
                 0.7X S FUEL OIL
NOX       9.3400 LB/H
                 EFFICIENT COMBUSTION
CO        3.1300 LB/H
                 EFFICIENT CCM3USTION

PM        0.0600 LB/H
                 EFFICIENT COMBUSTION
S02       0.2300 LB/H
                 0.7X S FUEL OIL
NOX       2.4800 LB/H
                 EFFICIENT COMBUSTION
CO        0.1SOO LB/H
                 EFFICIENT CCMDUSTION

PM       12.0000 LB/H
                 ESP
S02     205.4COO LB/H
BACT

BACT

BACT

BACT


BACT

BACT

BACT

BACT
                                                                                                                             NSPS
                                                                                                                             90.00
                                                                                                                             BACT
PAGE G- 427

-------
                                                                           HIGH TEMP REGEN.
                                                          NOX       37.0100 LE/H                                             BACT
                                                                           HIGH TEMP REGEH.
                                                          CO        90.1300 LB/H                                             BACT
                                                                           HIGH TEMP REGEN.
PAGE G-

-------
 (CONTINUED)  SIGMORE  REFIN. CO.
PROCESSES SUBJECT
TO THIS PERMIT
REBOILER, ISOSTRIPPER







BOILER







HEATER, VISBREAKER CHARGE







HEATER, VACUUM DISTALLATION








THROUGHPUT POLLUTANT
CAPACITY EMITTED
48.80 MMBTU/H
PM

S02

NOX

CO
167.80 MMBTU/H
PM

S02

NOX

CO
40.00 MMBTU/H
PM

S02

NOX

CO
96.50 MMBTU/H
PM

soa

NOX

CO

EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

3.3100 LB/H
EFFICIENT COQMBUSTION
38.6000 LB/H
0.7X S FUEL OIL
32.8700 LB/H
EFFICIENT COMBUSTION
1,6500 LB/H
EFFICIENT COMBUSTION
11.3600 LB/H
EFFICIENT COMBUSTION
138.7200 LB/H
O.T/. S FUEL OIL
113.0400 LB/H
EFFICIENT COMBUSTION
9.6800 LB/H
EFFICIENT COMBUSTION
2.7100 LB/H
EFFICIENT COMBUSTION
31.6400 LB/H
0.7X S FUEL OIL
26.9500 LB/H
EFFICIENT COMBUSTION
1.3500 LB/H
EFFICIENT COMBUSTION
1.6000 LB/H
EFFICIENT COMBUSTION
19.4900 LB/H
.77. S FUEL, SCRUB TO .1 GR/DSCF
CO. 8000 L3/H
EFFICIENT COMBUSTION
2.5000 LB/H
EFFICIENT COMBUSTION
... * BASIS
. . . PCT EFF

BACT

BACT

BACT

BACT

BACT

BACT

BACT

BACT

BACT

BACT

BACT

BACT

BACT

BACT

BACT

BACT

PAGE G- 429

-------
(CONTINUED) SIGMORE REFIN.  CO.
PROCESSES SUBJECT
TO THIS PERMIT
HEATER, 82 CRUDE UNIT








HEATER, VISBREAKER CHARGE








HEATER, CRUDE CHARGE








REBOILER, NAPHTHA STABILIZER








THROUGHPUT POLLUTANT
CAPACITY EMITTED
18.10 MMBTU/H
PM

S02

NOX

CO

40.00 MMBTU/H
PM

S02

NOX

CO

130.40 MMBTU/H
PM

SO 2

NOX

CO

19.50 MMBTU/H
PM

S02

NOX

CO

EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

0.2700 LB/H
EFFICIENT COMBUSTION
0.0100 LB/H
0.7X S FUEL OIL
4.1600 LB/H
EFFICIENT COMBUSTION
0.31CO LB/H
EFFICIENT COMBUSTION

2.7100 LB/H
EFFICIENT COMBUSTION
31.6400 LB/H
0.7X S FUEL OIL
26.9500 LB/H
EFFICIENT COMBUSTION
1.3500 LB/H
EFFICIENT COMBUSTION

8.8300 LB/H
EFFICIENT COMBUSTION
103.1400 LB/H
0.7X S FUEL OIL
87.8400 LB/H
EFFICIENT CCMSUSTION
4.4200 LB/H
EFFICIENT COMBUSTION

1.3200 LB/H
EFFICIENT CCMBUSTICN
15.4200 LB/H
o.?:: s FUEL OIL
13.1400 LB/H
EFFICIENT COMBUSTION
0.6600 LB/H
EFFICIENT COMBUSTION
... & BASIS
. . . PCT EFF

BACT

BACT

BACT

BACT


BACT

BACT

BACT

BACT


BACT

EACT

BACT

BACT


EACT

BACT

BACT

BACT

PAGE G- 430

-------
 (CONTINUED)  SIGMORE REFIN. CO.
HKULtSSES SUBJECT
TO THIS PERMIT
HEATER, NAPHTHA HDS CHARGE







REBOILER, NAPHTHA SPLITTER







HEATER, 1ST REFORMER







HEATER, 2ND REFORMER








THROUGHPUT POLLUTANT
CAPACITY EMITTED
36.40 MMBTU/H
PM

502

NOX

CO
27.30 MMBTU/H
PM

S02

NOX

CO
59.50 MMBTU/H
PM

S02

NOX

CO
52.80 MM3TU/H
PM

S02

NOX

CO

EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

0.1900 LB/H
EFFICIENT COMBUSTION
1.0000 LB/H
FUEL GAS SCRUB. TO 0.1 GR/DSCF
4.4600 LB/H
EFFICIENT COMBUSTION
0.6300 LB/H
EFFICIENT COMBUSTION
0.1400 LB/H
EFFICIENT COMBUSTION
0.7500 LB/H
FUEL GAS SCRUB. TO 0.1 GR/DSCF
3.3400 LB/H
EFFICIENT COMBUSTION
0.4700 LB/H
EFFICIENT COMBUSTION
0.3100 LB/H
EFFICIENT COMBUSTION
1.6300 LB/H
FUEL GAS SCRUB. TO 0.1 GR/DSCF
7.2900 LB/H
EFFICIENT COMBUSTION
1.0300 LB/H
EFFICIENT COMBUSTION
0.2700 LB/H
EFFICIENT CCMEUSTICM
1.4500 LB/H
FUEL GftS SCRUB. TO 0.1 GR/DSCF
6.4700 LE/H
EFFICIENT CCMEUSTICN
0.9200 LB/H
EFFICIENT CCM3USTIOM
... * BASIS
... PCT EFF

BACT

BACT

BACT

BACT

BACT

BACT

BACT

BACT

BACT

BACT

BACT

BACT

BACT

BACT

BACT

BACT

PAGE G- 431

-------
(CONTINUED) SIGT10RE REFIN. CO.
PROCESSES SUBJECT THROUGHPUT POLLUTANT
TO THIS PERMIT CAPACITY EMITTED
HEATER, 3RD REFORMER 26. 40 UMBTU/H
PM
EMISSION LIMITS ... & BASIS
CONTROL EQUIPMENT OR PROCESS MODIFICATION ... PCT EFF

0

.1400

LB/H



BACT
EFFICIENT OPERATION
S02

NOX

CO

HEATER, 4TH REFORMER 13.20 MMBTU/H
PM

S02

NOX

CO

REEOILER, REFORMER STABILIZER 16. 40 MMBTU/H
PM

S02

NOX

CO

REBOILER, KEROSENE HDS STRIPPER 13.60 MMBTU/H
PM

soa

NOX

CO

0

3

0


0

0

1

0


0

0

2

0


0

0

1

0

.7200

.2300

.4600


.0700

.3600

.6200

.2300


.0800

.4500

.0100

.2800


.0700

.3700

.6700

.2400

LB/H
FUEL GAS
LB/H
EFFICIENT
LB/H
EFFICIENT

LB/H
EFFICIENT
LB/H
FUEL GAS
LB/H
EFFICIENT
LB/H
EFFICIENT

LE/H
EFFICIENT
LB/H
FUEL GAS
LB/H
EFFICIENT
LB/H
EFFICIENT

LB/H
EFFICIENT
L3/H
FUEL GAS
LB/H
EFFICIENT
LB/H
EFFICIENT

SCRUB. TO 0.1 GR/DSCF

COMBUSTION

COMBUSTION


COMBUSTION

SCRUB. TO 0.1 GR/DSCF

COMBUSTION

COMBUSTION


COMBUSTION

SCRUB. TO 0.1 GR/DSCF

COMBUSTION

COMBUSTION


CFEPATION

SCRUB. TO 0.1 GR/DSCF

COMBUSTION

COMBUSTION
BACT

BACT

BACT


BACT

BACT

BACT

BACT


BACT

EACT

BACT

BACT


BACT

BACT

BACT

BACT

PAGE G- 432

-------
 (CONTINUED) SIGMORE REFIN. CO.
PROCESSES SUBJECT THROUGHPUT POLLUTANT
TO THIS PERMIT CAPACITY EMITTED
HEATER, GAS OIL HDS CHARGE 97.80 MMBTU/H
PM

S02

NOX

CO

REBOILER, DEETHANIZER 25.20 MMBTU/H
PM

S02

NOX

CO

= === ==:: = = = = = = = = = = = = = = = ===:: ===r === ==== === = === ======= = = === = ========
EMISSION LIMITS ...» BASIS
CONTROL EQUIPMENT CR PROCESS MODIFICATION . . . PCT EFF

0

2

11

1


0

0

3

0


.5000

.6800

.9800

.7000


.1300

.6900

.0900

.4400


LB/H
EFFICIENT
LB/H
FUEL GAS
LB/H
EFFICIENT
LB/H
EFFICIENT

LB/H
EFFICIENT
LB/H
FUEL GAS
LB/H
EFFICIENT
LB/H
EFFICIENT


COMBUSTION

SCRUB. TO 0.1 SR/DSCF

COMBUSTION

COMBUSTION


COMBUSTION

SCRUB. TO 0.1 GR/DSCF

COMBUSTION

COMBUSTION

BACT

BACT

BACT

BACT


BACT

BACT

BACT

BACT

NOTES
(*> INDICATES DATUM WAS TRUNCATED  FOR  THIS TABLE.

PAGE G- 433
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS-'  04/01/1983
                                                     ID NUMBER TX-0039
                                                                                                          SOURCE TYPE CCDE
                                                                                                                              5.5

-------
                                             APPENDIX —  DETAILED SOURCE LISTING
                                                                                                                        05/23/198-4



SOURCE TYPE/SIZE—-         PETROLEUM REFINING - AUXILIARY                                 31500.00  BPSD


COMPANY NAME/SITE LOCATION  SOUTHERN UNION REFIN.                                         LOVINSTON,  NM
                            5 MI SE LOVINSTON                                                                           LEA COUNTY


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE  OF PERMIT  ISSUANCE—  10/05/81
PERMIT NO. HM-350                                                                              ESTIMATED DATE  OF  START-UP—
DETERMINATION MADE BY       EPA REGION VI                  JOHN  BUNYAK                         (214)-767-1594
                             (AGENCY)                   (AGENCY  CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT       POLLUTANT    EMISSION LIMITS                                    ...  * BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT  OR  PROCESS MODIFICATION  ...  PCT  EFF


HEATER, 13 EA                        85.00 MMBTU/H
                                                           PM         0.0050  LB/MMBTU  GAS                                      BACT
                                                                            FUEL GAS  OS LOW SULFU3 OIL
                                                           S02        0.0270  LB/MMBTU                                          BACT
                                                                            FUEL OIL  OR NATURAL GAS
                                                           NOX        0.1200  LB/MM3TU                                          BACT
                                                                            LOU  NOX BURNERS
SULFUR RECOVERY UNIT
                                                           S02        0.8400  LB/H                                             BACT
                                                                            CLAUS UNIT


NOTES 	
13 HEATERS AND 1 SULFUR RECOVERY UNIT.









                                                                                                      INITIAL  REVIEW   POST  STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEW STATUS:   04/01/1933

PAGE G- 434                                           ID  NUMBER  NM-0004                                    SOURCE  TYPE CC3E    5.5

-------
                                             APPENDIX —• DETAILED SOURCE LISTING
                                                                                                                         05/22/1984
SOURCE TYPE/SIZE —
                            PETROLEUM REFINING - AUXILIARY
COMPANY NAME/SITE LOCATION TENNECO

DETERMINATION IS BACT FOR A MODIFIED SOURCE.
PERMIT NO. PSD-LA-199
DETERMINATION MADE BY EPA REGION VI
(AGENCY)
PROCESSES SUBJECT THROUGHPUT
TO THIS PERMIT CAPACITY
HEATERS, 26 287.00 MMBTU/H



BOILERS, 13 160.00 MMBTU/H



CO BOILER 350.00 MMBTU/H



FLARES, Z


SULFUR PLANT 6.60 KM3TU/H


CHAU1ETTE, LA

DATE OF PERMIT
ESTIMATED DATE
TOM DIGSS { £14 )-76 7-1594
(AGENCY CONTACT PERSON) (PHONE)

ST. BERNARD PARISH
ISSUANCE-- 12/23/81
OF START-UP-- 1934

POLLUTANT EMISSION LIMITS ... 4 BASIS
EMITTED CONTROL EQUIPMENT OR PROCESS MODIFICATION . . . PCT EFF

CO 0.0210 LB/MMBTU GAS
0.0300 LB/MMSTU OIL
02 MONITORING

CO 0.0210 LB/KNBTU GAS
0.0300 LB/MM3TU OIL
02 MONITORING

CO 0.0210 LB/MM3TU GAS
0.0300 LB/Hfi3TU OIL
02 MONITORING

CO 1.6000 LB/H EA
NONE

CO 0.0 330 LE/r,MBTU
NOSE

BACT



BACT



BACT



BACT


BACT

PAGE G- 437

-------
(CONTINUED) TENNECO
PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ...  4 BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ...  FCT  EFF
	_	— — _ — _ —	....	—	—	— _	____..	- —	— —	— — —	— — —	—	_-.___ — —	__ — _ — -. —	— —	— — ___-.	__	_	_•-__,.	«.	_-. — _— — -.—

FCCU REGEN                        42000.00 BPSD
                                                           CO      212.8000 LB/H                                             NSPS
                                                                            COMPLIANCE W/NSPS


NOTES 	
26 HEATERS RANGING IN SIZE FROM 11 TO 287 MMBTU/HR. 13 BOILERS RANGING IN SIZE FROM 24 TO 160 MMBTU/HR.
                                                                                                      INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:  04/01/19S3

PAGE G- 438                                           ID NUMBER LA-0022                                    SOURCE TYPE CODE     5.5

-------
                                              APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                           05/22/1984
 	= = - = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = === = = r = = = = :: = = = z = = == = = = = == = - = = = = = = :: = = = = :: = = === = :: = = = === = :: = = = = :: = ;: = ,=::- =


 SOURCE TYPE/SIZE	         PETROLEUM REFININS - AUXILIARY                                 100000.00 BPSD
                            — ""• — •" — —————— — — *-— — — — — — — — — — — _.-__.-__ ___.•___.»____ _^*fc—— •«_•«__ — _ w—.« ________ ^_».___—^,— „ __„,.. ___ _ „ _.. _ _—„__.. _ _« _ —

 COMPANY NAME/SITE LOCATION  TEXACO, INC.                                                    CONVENT, LA
                                                                                                                    ST. JAMES  PARISH
                            ~~~~~~~~ —~~~~™~™~~~~^ — ~ — ~ — — ™~ — — ™^ — —— ™ — — ™ — — —— — — ^ — — —— — — ~ —— — — — — — — — — — — — — — — — — ^ — —— — — — -• — — — — ».. — — .._ — *.__....._,»,_.•.»__

 DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE OF PERMIT ISSUANCE- 11/16/81
 PERMIT NO. (REGION FILE NO.) PSD-LA-420                                                         ESTIMATED DATE OF START-UP-
 DETERMINATION MADE BY       EPA REGION VI                  JOHN BUNYAK                          <214)-767-1594
                              (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)

 = = = rrrrr = rr = r = r = rr = r = rr = = = = = = r = = : = = :r = r = = = r = = = = - = ~rr = = r = = = = = = = = = = = = = = r = rr = = = = = = = = = = = r = = = ::::z:- = ::-:: = :.::_ = =	

 PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... 4 BASIS
 TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ." PCT  EFF
 ~  -----------------  -_-   _-_	-.-__«...._	,	__	_____^__,...	„_ ---__-____..___	-__	_	„__,	_.„	„		^____._	-__fc	--_-_._

 HEATERS,  15 EA                      198.00 MMBTU/H
                                                            CO        0.0300 LB/MMBTU                                         BACT
                                                                             FLUE GAS 02 MONITOR
                                                                             LOU  EXCESS AIR
 ACID GAS INCIN.                        8.00 MMBTU/H
                                                            CO        0.9300 L8/KMBTU                                         BACT
 _n_ T.,-T.,cniT«                                                              L0'^  EXCESS AIR, FLUE GAS 02 MONITOR
 ERG INCINERATOR                       13.10 MMBTU/H
                                                            CO        0.0200 LB/MMBTU                                         BACT
                                                                             LOU  EXCESS AIR, FLUE GAS 02 MONITOR


 S'OTES	












 <*>  INDICATES  DATUM  WAS  TRUNCATED  FDR  THIS TABLE.                                          REVIEW STATUS^"J/Ol/lS!"  P°ST STARTUP

PAGE  G- <+39                                            ID  NUMBER LA-0007                                     SOURCE TYPE CODE    5.5

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1934



SOURCE TYPE/SIZE	         PETROLEUM REFINING - AUXILIARY                                140000.00 BPSD


COMPANY NAME/SITE LOCATION  TEXACO, INC.                                                   CONVENT, LA
                                                                                                                  ST.  JAMES PARISH


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE—  04/23/81
PERMIT NO. (REGION FILE NO.) PSD-LA-378                                                        ESTIMATED DATE OF START-UP--
DETERMINATION M/DE BY       EPA REGION VI                  JOHN BUNYAK                         (214>-767-1594
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ...  & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS MODIFICATION   ...  PCT EFF


MTU-CRU FLUE GAS COOLER             670.00 MMBTU/H
                                                           CO        0.02CO LB/MMBTU                                         BACT
                                                                            HIGH TEMP REGENERATION (HTR )
INCIN., 3 EA                         13.10 MMBTU/H
                                                           CO        0.0200 LB/t-r.STU                                         BACT
                                                                            HIGH TEMP REGENERATION (HTR)
POWER RECOVERY STACK
                                                           CO                                                                NSPS
                                                                            LIMIT EMISSIONS TO 500 PPM


NOTES 	











                                                                                                      INITIAL REVIEW  POST  STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEW STATUS:   04/01/1933

PAGE G- 440                                           ID NUMBER LA-0024                                    SO'JRCE  TYPE CODE    5.5

-------
                                              APPENDIX — DETAILED  SOURCE LISTING
 __		                                                                                                             05/22/1984
 	= - = = = = = = = = :: = = = = :: = = = = = = = ::=:= = = = = = = = = = = = = = = = = = = = = = = = = === = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = r = = = = = = ==r = = === = ==== = -r = r = = = = r = =

 SOURCE  TYPE/SIZE—         PETROLEUM REFINING - AUXILIARY
                            "~  """ "*"" ~"	""""	~	~	""	~~~~~~~~~~ — ~ — — — —~ — — — — — — ~ — — — — — —~ — — — — — — — — — — — — — — — — — — — — — — — ~ —— — — __.-.._...-_..,._«,-._

 COMPANY NAME/SITE LOCATION  TEXACO, INC.                                                PORT ARTHUR, TX 77640
                             P.O. BOX 712                                                                           JEFFERSON COUNTY
                            ~  ~~~	_--	--__..____,. _.»____*.	-.-_ — ..__-..,__,-,_,__.-.,..__,.____	-.-_ — -._-____.	_.	__»____

                        °R * "ODIFIED SOURCE-                                                    DATE OF PERMIT ISSUANCE-  06/20/79
 DETERMINATION MADE BY       EPA REGION VI                  JOHN BUNYAK                          ff™767-15™ ^ ^^~VP~~
                              (AGENCY)                   (AGENCY CONTACT  PERSON)                    CPHONE)


 PROCESSES  SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION .LIMITS                                    ..   & BASIS
 _____    PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF
                                      "~ " "*~~~—™ — •• — •* «- — — — — — — — — — — — _ -.__«_-.__. «._^_ -_«_ _ ».•_ _ « _ — ^_-_»™ — «._-.-__. —_ _^_ ___-__._»__ fc — — — — » — — ••-_•»__» — ^ —^__

 FCCU                                 170.00 MBBL/D
                                                            S02     406.3000 LB/H                                              NSPS
 HFATFD  «^n7                                                                  SOX REDUCTION CATALYST                            75.00
 HEATER  81407                          30.74 SCFM
                                                            S02       4.5000 LB/H                                              NSPS
 FLUE GAS SCRUB./SULFUR  RECOVERY                                              °'1 GR/°SCF'  ^ ^^
                                                            502       1.1000 LB/H SEE NOTE                                     NSPS
                                                                              TAIL GAS TREATING UNIT                            99.97

NOTES —	-
NOTE: F.G. SCRUB./S  RECOVERY  EMISSIONS ARE INCREASE ONLY OVER EXISTING CONDITIONS.









(*) INDICATES DATUM  WAS TRUNCATED FOR  THIS TABLE.                                          REVIEW STATUS^oJ/Ol/l?""   P°S

PAGE G- 441                                            ID  NUMBER  TX-OC64                                     SCARCE TYPE CCDE

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1934



SOURCE TYPE/SIZE	         PETROLEUM REFININS - AUXILIARY


COMPANY NAME/SITE LOCATION  TOSCO CORP.                                                BAKERSFIELD,  CA


DETERMINATION IS      FOR A MODIFIED SOURCE.                                                   DATE  OF PERMIT ISSUANCE--  06/18/SO
PERMIT NO. (REGION FILE NO.) SJ-73-26                                                          ESTIMATED DATE OF START-UP-
DETERMINATION HADE BY       EPA REGION IX                  DAVID SOLOMON                       (415)-974-8066
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHCHE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ...  « BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ...  PCT EFF


CO BOILER                         92700.00 LB/H
                                                           CO       45.7000 LB/H                                             LAER
                                                                            BOILER BURNS CO EMITTED  FROM TCC UNIT            99.40
                                                           S02        0.5000 7. S FUEL                                         LAER
                                                                            SULFUR IN AUXILLARY FUEL OIL
                                                           NOX       41.0000 LB/H                                             BACT
                                                                            COMBUSTION MODIFICATION  BASED ON 0.3 LB/MMBTU


NOTES 	
THERMOFOR CATALYTIC CRACKING. INSTALLATION OF CO BOILER  ON REFINERY TCC1  UNIT
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 442
                                                INITIAL REVIEW  POST STARTUP
                                   REVIEW STATUS:   04/01/1933    04/04/1934
ID NUMBER CA-0007
                                                     SCL'SCE TYPE CODE
                                                                         5.5

-------
                                             APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                         05/22/1984
SOURCE TYPE/SIZE—
                             PETROT.EUM REFINING - AUXILIARY
COMPANY NAME/SITE  LOCATION  TOSCO CORP.
                                                                                           MARTINEZ, CA
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT NO. 27769
DETERMINATION MADE BY       BAY AREA AQMD
                              (AGENCY)
   JIH KARAS
(AGENCY CONTACT PERSON)
DATE OF PERMIT ISSUANCE—   02/19/82
ESTIMATED DATE OF START-UP—    1983
(415J-771-6COO
    (PHONE)
PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION  LIMITS                                   ... i BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
     """ ~~~*"~~ — *~ — ~~-"~ —•• — — — — — — — — —-— — — __ — — __..______ _» —_ «. „. __ „.„_ __ _„„»_»___ _»._„ __ .._______,»._,„... __ — «. — «• — _•.»__«.__ ,„__.„ -._..__•___-_ _ _.»™. _ —__—.™ — __^.__

FURNACE, REFINERY PROCESS, 2 TO*    119.00 MM3TU/H SEE*
                                                           NOX      40.0000  PPM  AT  37.  02                                      BACT
                                                                             LOW  NOX BURNERS/1 SCR UNIT FOR BOTH FURNACES     70.00
FURNACE, REFINERY PROCESS            40.00 t^BTU/H
                                                           NOX      40.0000  PFM  AT  3X  02                                      BACT
                                                                             LOW  NOX BURNERS / SCR                            70.00


NOTES 	
BURNING REFINERY FUEL GAS WITH HEAT VALUE OF 1025 BTU/CF. NOTE — THROUGH  PUT  CAPACITY IS TOTAL CAPACITY. ONE IS 67. MfJBTU/H,
THE OTHER IS 52. MHBTU/H.















                                                                                                       INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FCR THIS TABLE.                                         REVIEW STATUS'-   04/19/1984

PAGE G- 443                                           ID NUMBER CA-0046A                                    SOURCE TYPE CODE    5.5

-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/22/1984
SOLACE TYPE/SIZE	
                            PETROLEUM REFINING  - AUXILIARY
                                                                                          10000.00 BBL/D
COMPANY NAME/SITE LOCATION  UNI OIL
                                                                                        INGLESIDE, TX
                                                                                                              SAN PATRICIO COUNTY
DETERMINATION IS BACT FOR A MODIFIED SOURCE.
PERMIT NO. (REGION FILE NO.) PSD-TX-229
DETERMINATION MADE BY       EPA REGION VI
                             (AGENCY)
   JOHN BUNYAK
(AGENCY CONTACT PERSON)
DATE OF PERMIT ISSUANCE--  03/12/80
ESTIMATED DATE OF START-UP--
(214J-767-1594
    (PHONE)
PROCESSES SUBJECT THROUGHPUT POLLUTANT EMISSION LIMITS ... t BASIS
TO THIS PERMIT CAPACITY EMITTED CONTROL EQUIPMENT OR PROCESS MODIFICATION ... PCT EFF
HEATER, VACUUM 66.65 KMBTU/H
S02 1
0

PM 1
0

NOX 11
0

CO 1
0

VOC 0
0

FCC UNIT 17000.00 BBL/D
S02 64

PM 12
1


.2700 LB/H
.0190 LB/WBTU
FUEL GAS: o.l GR/DSCF H2S
.5100 LE/H
.0230 LB/MM3TU
COMBUSTION CONTROL
.6000 LB/H
.1740 LB/HM3TU
CC^:3US. CONTROL/LOW NOX BURN.
.6700 LB/H
.0250 LB/MM3TU
CCM3USTION CONTROL
.1600 LB/H
.0024 LB/MfiBTU
COMBUSTION CONTROL

.1000 LB/H
F. G. :0.1 GR/DSCF H2S
.0000 LB/H
.COCO LB. MLB COKE BURN OFF •
ESP

NSPS


BACT


BACT


BACT


BACT



NSPS

NSPS


PAGE G- 444

-------
                                                           NOX      29.4000 LB/H                                             BA.CT
                                                                            CKBST. CONTRL.  fc LOW NOX BURN.
                                                           CO       89.1000 LB/H                                             NSPS
                                                                            HIGH TEMP.  REGENERATION
                                                           VOC       2.6000 LB/H                                             BACT
                                                                            COMBUSTION CONTROL
PAGE G- 445

-------
(CONTINUED) UNI OIL
PROCESSES SUBJECT THROUGHPUT
TO THIS PERMIT CAPACITY
HEATER, ISOSTRIPPER 38.24 MMBTU/H















TAIL GAS INCIN




REGENERATOR, HYDROTREATER CATAL*




HEATER, REFORMER 161.00 MM3TU/H











POLLUTANT
EMITTED

S02


PM


NOX


CO


VOC



S02

NOX


S02

PM


S02


PM


NOX


CO

EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

0.6300 LB/H
0.0790 LB/MM8TU
F.G. : 0.01 GR/DSCF H2S
0.8700 LB/H
0.0230 LB/MMBTU
COMBUSTION CONTROL
6.8500 LB/H
0.1790 LB/MMBTU
CM3ST. CONTRL./LOW NOX BURN.
1.1100 LB/H
0.0290 LB/Mr;BTU
COMBUSTION CONTROL
0.1600 LB/H
0.0042 LB/MMBTU
COr.BUSTICN CONTROL

39.7000 LB/H
NO CONTROL
0.0790 LB/H
NO CONTROL

0.2400 LB/H
F.G. : 0.1 GR/DSCF H2S
0.7900 LB/H
COMBUSTION CONTROL

1.9000 LB/H
0.0120 LE/t.MBTU
F.G. : 0.1 GR/DSCF
0.0790 LB/H
0.0005 LB/r;r:BTU
cc::3USTioN CONTROL
43.8000 LB/H
0.2700 LB/MM3TU
CMBST. CONTRL./LOW NOX BURN.
6.7500 L3/H
0.0420 LB/MMBTU
... 8 BASIS
. . . PCT EFF

NSPS


BACT


BACT


BACT


BACT



BACT

BACT


NSPS

BACT


NSPS


BACT


BACT


BACT

PAGE G-

-------
                                                                            COMBUSTION CONTROL
                                                           VOC       0.8000 LB/H                                             BACT
                                                                     0.0050 LB/MMBTU
                                                                            COMBUSTION CONTROL
PAGE G-

-------
(CONTINUED) UNI OIL
PROCESSES SUBJECT THROUGHPUT
TO THIS PERMIT CAPACITY
HEATER, 80S 40.00 MMBTU/H















BOILER, PACKAGE 103.24 MMBTU/H















NOTES 	
THE NEW FACILITY WILL NOT INCREACE THE REFINERIES CP.UDE
ED GASOLINE.

(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.
POLLUTANT EMISSION LIMITS
EMITTED CONTROL EQUIPMENT OR PROCESS MODIFICATION

S02 0.4800 LB/H
0.0120 LB/MMBTU
F.G. : 0.1 GR/DSCF H2S
PM 1.4300 LB/H
0.0360 LB/MMBTU
COMBUSTION CONTROL
NOX 10.9000 LB/H
0.2700 LB/MMBTU
CMBST. CONTRL./LOW NOX BURN.
CO 1.6700 LB/H
0.04EO LB/MMBTU
COMBUSTION CONTROL
VOC 0.1600 LB/H
0.0040 LB/MMBTU
COMBUSTION CONTROL

S02 0.7900 LB/H
0.0077 LB/MMBTU
F.S. : 0.1 GR/DSCF
PM 1.5900 LB/H
0.0150 LB/MMBTU
COMBUSTION CONTROL
NOX 7.9400 LB/H
0.0760 LB/MMBTU
COMBUSTION CONTROL
CO 0.7100 LB/H
0.0069 LB/MM3TU
COMDUSTION CONTROL
VOC 0.0600 LB/H
0.0006 LB/t'.r'.BTU
COMBUSTION CONTROL

... S BASIS
. . . FCT EFF

NSPS


BACT


BACT


BACT


BACT



NSPS


BACT


BACT


BACT


BACT



HANDLING CAPACITY, BUT WILL ENABLE THE REFINERY TO MAKE PREMIUM UNLEAD

INITIAL F* VIEW
REVIEW STATUS; 0^/01/1^33

POST STARTUP

PAGE G- 448
                                                     ID NUMBER TX-0061
                                                                                                          SCURCE TYPE CCOE    5.5

-------
                                               APPENDIX — DETAILED SOURCE LISTING
 ==="= = "="="="~rrr=========r===== ==-..--__=_____:...:______=	^             ^                   05/22/1984


 SOURCE TYPE/SIZE—          PETROLEUM REFINING - AUXILIARY

 COMPANY NAME/SITE  LOCATION   UNION  OIL                                                   ROHEOVILLE,  IL
                                                             """'""'~'™"~"~-'" —~"~- —— —— —"* — — -• — — — — — — — — —	— — — — — — — •» — — — — «- — — — — — — —__..,._,...___-.M._ — ____
 DETERMINATION IS BACT FOR A  NEW SOURCE
 PERMIT NO. 83 01 0013                                                                           DATE  OF PERMIT ISSUANCE—  06/09/83
 DETERMINATION HADE BY        ILLINOIS  EPA                    CHRIS ROHAINE                       *1™"H llll " START-UP~   198S
                              (ASENCY)                    "AGENCY CONTACT PERSON)                    (TOME?


                                                                                 iniTS                                    ...  i BASIS
                                                                        ^     CONTROL EQUIPMENT OR PROCESS MODIFICATION  ...  PCT EFF

 HEATER,  W/AIR PREHEAT, 2 TOTAL      18-*. 00 MMBTU/H
                                                            NOX        0.1600 LB/MMBTU                                          BACT
 HEATER,  W/0 AIR PERHEAT, 3 EA        25.00 KMSTU/H MAX                       EQUIPMENT DESIGN,  EXCESS AIR  ANALIZERS
                                                            NOX        0.1300 LB/TM8TU                                          BACT
                                                                              EQUIFMENT DESIGN,  EXCESS AIR  ANALIZERS

 NOTES  	
 PROJECT HAS NOT  A  MAJOR  MODIFICATION FOR S02. S02 EMISSIONS GOVERNED BY NSPS.  ALSO PERMIT NtttBER  197 090 AAI.











(*> INDICATES DATUM WAS TRUNCATED FOR  THIS TABLE.                                         DCWTC,, <:      INITIAf- REVIEW  POST STARTUP
~ — — — ~^z:~zr!~~~~2~'— — — — — — — — — — — — — — •.-._ -* — ».__—                                                   KtVJtW STATUS *

PAGE G~

-------
                                             APPENDIX -- DETAILED SOURCE LISTING
                                                                                                                        05/22/1934




SOURCE TYPE/SIZE---         PETROLEUM REFINING - AUXILIARY                                 46500.00 BPSD
                                                    „. ________ — — .— — .,_—.—. — — — _ — —,,•. — — •- — — — — — — — — — — — — — — — — •— — •— — — — — — — — — — .» — — — — .- — — — — — — — — — — — — — •— — •••


COMPANY NAME/SITE LOCATION  VENTECH REFIN.                                           KROTZ SPRINGS, LA



DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE QF PERMIT ISSUANCE-  02/13/80
PERMIT NO. (REGION FILE NO.) PSD-LA-232                                                        ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY       EPA REGION VI                  JOHN BUNYAK                         <214 )-767-1594
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... k BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
CATALYTIC REGEN
SULFUR RECOVERY PLANT
FCCU FURNACE
                                     50.00 MMBTU/H
PM       14.6000 LB/H
                 3 STAGE CYCLONE
S02     265.2000 LB/H
                 LOW H2S FUEL (OIL LB/DCSF)
NOX      66.6000 LB/H
                 LCV4 EXCESS AIR
VOC       2.2000 LB/H
                 LCW EXCESS AIR
CO      104.7000 LB/H
                 PLOT REGEN

S02       2.1000 LB/H
                 NONE

PM        0.0200 LB/Mr3TU
                 EFFICIENT OPERATION
S02       0.0260 LB/MM3TU
                 LC^I HCS FUEL
NOX       0.2300 LB/MMSTU
                 LOU EXCESS AIR - COMBST CONTRL
VOC       0.0060 LB/MMBTU
BACT
94.00
NSPS

BACT

BACT

NSPS
99.90

NSPS


BACT

NSPS

BACT

BACT
PAGE G- 450

-------
                                                                            EFFICIENT OPERATION
                                                           CO        0.0200 LB/MMBTU                                         NSPS
                                                                            LOW EXCESS AIR
PAGE G- 451

-------
(CONTINUED) VENTECH REFIN.
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
« BASIS
PCT EFF
VACUUM FURNACE
                                    100.00  MMBTU/H
                                                          PM         0.0200  LB/MNBTU
                                                                            EFFICIENT OPERATION
                                                          S02        0.0260  LB/MM3TU
                                                                            LOW H2S FUEL
                                                          NOX        0.2300  LB/MMBTU
                                                                            COMBUSTION CONTROLS
                                                          VOC        0.0060  LB/MK3TU
                                                                            EFFICIENT OPERATION
                                                          CO         0.0200  LB/MMBTU
                                                                            LOW EXCESS AIR
                                                                                       BACT

                                                                                       NSPS

                                                                                       BACT

                                                                                       BACT

                                                                                       BACT
NOTES
<*> INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 452
                                                                                                     INITIAL REVIEW  POST STARTUP
                                                                                        REVIEW STATUS:
                ID  NUMBER  LA-0029
                                                                     SOUSCE  TYPE  CODE
                                                                                         5.5

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/23/1934
 SOURCE TYPE/SIZE	
                            PETROLEUM REFINING - ENTIRE OPERATION
COMPANY NAME/SITE LOCATION  CHEVRON USA LUBE OIL
                                                                                          RICHMOND, CA
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT NO. 27797
DETERMINATION MADE BY       BAY AREA AQMD
                             (AGEK'CY ;
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
                     ELLEN LINOEP
                  fAGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE—  04/OS/82
                                       ESTIMiTED DATE OF START-UP--   1984
                                       14151-771-6000
                                           (PHONE;
POLLUTANT    EMISSION LIMITS                                   . . . £ B
 EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... FCT
GAS COMPRESSOR, 9 EA
                                           SEE NOTE
                                                           voc
                                                                     0.3000 LB/D PER SEAL
                                                                            SEAL/VAPOR RECOVERY
                                                                                                                             99.00
NOTES 	
CAPACITY 20 HP TO 1000 HP. FILE A 350-011
<*) INDICATES DATUM WAS TRUNCATED FOF? THIS  TABLE.

PAGE G- 453
                                                                INITIAL REVIEW  POST STARTUP
                                                   REVIEW STATUS:   04/19/1^34
                                                      ID  NUMBER  CA-0045A
                                                                                                           SOURCE TYPE CODE    5.6

-------
                                             APPENDIX —  DETAILED  SOURCE LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE —
                            PETROLEUM REFINING - ENTIRE OPERATION
                                                                                              21.00 MBBL/D
COMPANY NAME/SITE LOCATION  GARY WESTERN REFIN.
                            GARY COMMUNITY RUAL  STATION
                                                                                            FRUITA,  CO 81521
                                                                                   MESA COUNTY
DETERMINATION IS BACT FOR A MODIFIED SOURCE.
PERMIT NO.
DETERMINATION MADE BY       EPA REGION VIII
                             (AGENCY)
                       JOHN DALE
                    (AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE--  06/24/81
                                       ESTIMATED DATE OF START-UP--
                                       (303)-837-3763
                                           (PHCHE)
PROCESSES SUBJECT
TO THIS PERMIT
  THROUGHPUT
   CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
...  & BASIS
...  PCT  EFF
VAP. REC. GAS CONT.


BOILER *4


CRUDE UNIT


DISTILLATE HDS


GILSONITE MELT


HYDRCCRACKER
                                     18.00 MMSCFD
 47.00 MLB/H STEAM
 21.00 MBPSD
  7.35 MBPSD
565.00 T/D
  8.40 M3PSD
   NQX       1.2600 LB/H
                    LOW NOX BURNERS

   NOX       8.4100 LB/H
                    LOW NOX BURNERS

   NOX       5.3100 LB/H
                    LOW NOX BURNERS

   NOX       3.4200 LB/H
                    LOW NOX BURNERS

   NOX       3.6000 LB/H
                    LOW NOX BURNERS

   NOX       6.0200 LB/H
                    LOW NOX BURNERS
                                                                                         BACT
                                                                                         BACT
                                                                                         BACT
                                                                                         BACT
                                                                                         BACT
                                                                                                                             BACT
PAGE G- 454

-------
 (CONTINUED) GARY WESTERN REFIN.
 PROCESSES SUBJECT
 TO THIS PERMIT
  THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... 4 BASIS
   CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
 MARUZEN LUMMIS


 NEW H2 PLANT


 PLATFORMER


 SUL RECOV PLANT



 SUL RECOV PLANT
  3.15 MBPSD


650.00 MSCFD


  6.30 MBPSD


 25.00 T/D



 25.00 T/D
NOX       1.4400  LB/H
                  LOW NOX BURNERS

NOX      13.3200  LB/H
                  LOW NOX BURNERS

NOX      10.0900  LB/H
                  LOW NOX BURNERS

502     250.0000  PPM
         60.1000  LB/H
                  TAIL GAS SCRUBBER

NOX       0.3600  LB/H
                  LOW NOX BURNERS
BACT


BACT


BACT


BACT

99.00

BACT
 NOTES
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TADLE.

PAGE G- 455
                                                                 TNTTIAL OFVIEW  POST STARTUP
                                                                b.   0 », 01/19S3
                                                                                                                               5.6

-------
                                             APPENDIX — DETAILED SOURCE LISTING                                         „ ,-,„,•,„«/
                                                                                                                         05/22/1S8H




SOURCE TYPE/SIZE—         PETROLEUM REFINING - ENTIRE OPERATION                      _  184000.00 EPSD



COMPANY NAME/SITE LOCATION  HAMPTON ROADS ENERGY CO,                                    PORTSMOUTH, VA       pORTSHOUTH  CITY  COUNTy

                                                                                         _ — -.-. __ — • — — — — «. — «. — -• — — — — — — — — — — — — — —••— — — — — — -*•"• — —
                           _„ — — -. __™_—_—™— — — _ — _ — _ — — — — — — — — •— — — — — • — — «,__^ — » — -. — — — •— — — „____». —— — — — — — •- —

ncTCDMTwsTrnM T* RAPT FOP A NEW SOURCE                                                         OATE OF PERMIT ISSUANCE—  01/25/80
PPPMTT m  7RVA01                                                                              ESTIMATED DATE OF START-UP-
PERMIT NO. 78VA01                                                                                 _. _Q, C1C7
DETERMINATION MADE BY       EPA REGION III                 EILEEN GLEN                         (215 -597-S187
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)

                         	=-====-===——-======r===========================================


   „- Eg SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    • • • * BA?Jf
?5 THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT  EFF
HEATER, RESIDUE HDS, STACK 1.
                                     32.00 MMBTU/H
HEATER, HYDROGEN  PLANT,  STACK  1.     770.00 MMBTU/H
 HEATER,  SULFUR  PLANT,  STACK 1.
                                      50.00  MMBTU/H
PM
SQZ

NOX

CO


PM
S02

NOX

CO
                                                            PM
                                                            S02

                                                            NOX
 18.0000
 96.0000

 60.0000

 11.0000


 43.0000
£32.0000

144.0000

 25.0000
LB/H
LB/H
0.3X S FUEL
LB/H
LOU NOX BURNERS
LB/H
GOOD OPERATION

LB/H
LB/H
0.3X S FUEL
LB/H
LC1.) NOX BURNERS
LB/H
GOOD OPERATION
          4.0000  LB/H
         15.0000  LB/H
                  0.3X S  FUEL
         15.0000  LB/H
                  LOW NOX BURNERS
BACT
HAAQ

BACT

BACT


BACT
NiU

BACT

BACT
                                                          BACT
                                                          NAAQ

                                                          BACT
 PAGE G- 456

-------
                                                           CO        2.0000  UB/H                                             BACT
                                                                             SOOD OPERATION
PAGE G- 457

-------
(CONTINUED)  HAMPTON  ROADS  ENERGY CO.
PROCESSES SUBJECT THROUGHPUT
TO THIS PERMIT CAPACITY
SULFUR RECOVERY UNIT

HEATER, DISTILLATE HDS, STACK 2. 130.00 MMBTU/H






HEATER, NAPHTHA HDS, STACK 2. 260.00 MMBTU/H






HEATER, CATALYTIC REFORMER, STA* 520.00 MMBTU/H






HEATER, ISOMERIZATION UNIT, STA* 95.00 MMBTU/H







POLLUTANT
EMITTED
S02

PM
S02

NOX

CO

PM
S02

NOX

CO

PM
S02

NOX

CO

PM
S02

NOX


CO

EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION
152.0000 LB/H
BEACON UNIT OR EQUIVALENT
7.0000 LB/H
39.0000 LB/H
0.3X S FUEL
24.0000 LB/H
LOW NOX BURNERS
4.0000 LB/H
GOOD OPERATION
15.0000 LB/H
78.0000 LB/H
0.3X S FUEL
49.0000 LB/H
LOW NOX BURNERS
9.0000 LB/H
GOOD OPERATION
29.0000 LB/H
152.0000 LB/H
0.3X S FUEL
97.0000 LB/H
LCW NOX BURNERS
17.0000 LB/H
GOCD OPERATION
6.0000 LB/H
28.0000 LB/H
0.3X S FUEL
18.0000 LB/H
LOW NOX BURNERS
LOW NOX BURNERS
3.0000 LB/H
GOOD OPERATION
... 4 BASIS
. . . FCT EFF
NAAQ
99.50
BACT
NAAQ

BACT

BACT

BACT
NAAQ

BACT

BACT

BACT
NAA3

BACT

BACT

BACT
NAAQ

BACT


BACT

PAGE G- 458

-------
 (CONTINUED) HAMPTON ROADS ENERGY CO.

PROCESSES SUBJECT THROUGHPUT
TO THIS PERMIT CAPACITY
HEATER, ATMOS. CRUDE DISTIL, ST* 505.00 MMBTU/H






GEN, UTILITY STEAM, STACK 3 60.00 MMBTU/H






C 1 An Tl 1^*

POLLUTANT
EMITTED

PM
502

NOX

CO

PM
S02

NOX

CO


EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

29.0000 LB/H
152.0000 LB/H
0.3X S FUEL
95.0000 LB/H
LOW NOX BURNERS
17.0000 LB/H
GOOD OPERATION
34.0000 LB/H
180.0000 LB/H
0.3X S FUEL
106.0000 LB/H
LOW NOX BURNERS
20.0000 LB/H
GOOD OPERATION

... * BASIS
. . . PCT EFF

BACT
NAAQ

BACT

BACT

BACT
NAAQ

BACT

BACT

                                                           soz
                                                                     8.0000 LB/H
                                                                                                                             BACT
NOTES 	


"" " «;;""£! p"!""™" BY NAAQS & PS° CUSS « INCREHEMT CONSTRAINTS. S02 EMISSIONS FROM START-UP OF LPG PLANT TO BE OF
row t D i KcbUU I xUro rKUfl OTHER SOURCES.

TANKERS BURN FUEL WITH S CONTENT <1.0X.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.


PAGE G- 459
             INITIAL REVIEW  POST STARTUP

REVIEW STATUS:  04/01/1983
                                                      ID NUMBER VA-0005
                                                                                                           SCITCCE TYPE CODE
                                                                                                                               5.6

-------
                                             APPENDIX « DETAILED SOURCE LISTING
                                                                                                                        05/22/1984




SOURCE TYPE/SIZE—         PETROLEUM REFINING - ENTIRE OPERATION                            750.00 MBPSD
                           _. _ .. — ___ ________ — -_ — _—————— — ——— — _—.»•—— — —.«..*•—. — — •— — — .— • — ™^™^—,«-— • — — — — ««.— — — —— — ——— ___.»__..»«.——— — «-— — — — —•••—»- — — —— — —— — —


COMPANY NAME/SITE LOCATION  HESS OIL - VIRGIN ISLANDS                                    ST. CROIX, VI 00806
                           _______.._.._____,,.._-	«,_„_„___-______ — — - — «-- — -- — ----- — - — ----------- — ---- — ------- — --- — — — — - — --- — --- — — — - —


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE—  02/09/82
PERMIT NO. NONE                                                                                ESTIMATED DATE OF START-UP—   19S5
DETERMINATION MADE BY       EPA REGION II                  ED NOWAK                            (212)-264-6690
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE )




PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
FCC UNIT, 2
                                 152734.00 BBL/D
PROCESS HEATERS, 3
SOZ       0.6000 7. BY WT
                 USE OF LOW S FEED STOCK VOG
PM        0.8UOO LB/MLB COKE BURN
                 ESP
NOX     175.0000 PFM 2X 02
                 LEA 4 LCU COMBST TEMPS
CO      500.0000 PPM VOL
                 CO BURNING REGENERATOR
VOC
                 CO BURNING REGENERATOR

S02       0.1000 GR/OSCF H2S,GAS
          0.5000 7. S OIL
                 LOW S GAS OR OIL
PM        0.1000 LB/r.!3TU
                 PROPER MAINTENANCE
NOX       0.2000 LB/MMBTU GAS
          0.3000 LB/Mf'.STU OIL
                 LEA & WASTE HEAT REC.
CO        0.2000 LB/HMBTU GAS
          0.3000 LB/MM3TU OIL
                 LEA fc WASTE HEAT REC.
                                                                                                                             BACT

                                                                                                                             BACT
                                                                                                                             95.00
                                                                                                                             BACT

                                                                                                                             BACT
                                                                                                                             NSPS


                                                                                                                             NSPS

                                                                                                                             BACT


                                                                                                                             BACT
PAGE G- 460

-------
                                                            VOC       0.2000 LB/HMBTU GAS                                     BACT
                                                                      0.3000 LB/MMBTU OIL
                                                                             LEA & WASTE HEAT REC.
PAGE G- 
-------
(CONTINUED) HESS OIL - VIRGIN ISLANDS
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS                                   ... t BASIS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
FUGITIVE EMISSION SOURCES
                                                           VOC
                                                                                                                             BACT
                                                                            GOOD ENGINEERING PRACT.
NOTES
(*) INDICATES DATUM WAS TRUNCATED FOR THIS  TABLE.

PAGE G- 462
                                                               INITIAL REVIEW  POST STARTUP
                                                  REVIEW STATUS:
                                                     ID NUMBER VI-OOOZ
                                                                                                          SOURCE TYPE CODE    5.6

-------
                                              APPENDIX — DETAILED SOURCE LISTING
 -----__-.-___.___.__._______.._	_	                      _                                 05/2Z/1984



 SOURCE TYPE/SIZE—         PETROLEUM REFINING -  ENTIRE  OPERATION


 COMPANY NAME/SITE LOCATION  HILL PETROLEUM CO.                                        KROTZ SPRINGS, LA
                            ~~"     ~~~'	--__	— _--_ — __-__«.	„	___	-_„«_.	-__«,_	„._..	«._- — -___-._. — „_____	— »_„ — __..__

 DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE OF PERMIT ISSUANCE    10/09/fiQ
 PERMIT NO.  (REGION FILE NO.) PSD-LA-286A                                                        ?£in£e0 DATE OF START UP 10/°9/8°
 DETERMINATION MADE BY       EPA REGION VI                   JOE  WINKLEP                         m™-76?-?&5o
                              (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)

                     = = ======== = = « = === = = «=««= = ^^

                                       THROUGHPUT         POLLUTANT    EMISSION LIMITS                                   ...» BASIS
                                        CAPACITY           EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ...PCT EFF
 LIQ. STORAGE TANKS  «  11.1  PSIA*
 LICJ. STORAGE TAWS  (>  11.1 PSIA«
LIQUID PETROLEUM PUMPS
LIQUID PETROLEUM BARGES
HEATER, REFORMER CHARGE
                                    100.15 MMBTU/H
                                                           VOC
                                                           VOC
                                                           VOC
                                                           VOC
                                                           NOX
                                                           CO
                                                                             FLOATING ROOF  TANK W/DBL SEALS
                                                                             PRES.  VESSELS W/ VAPOR BAL.
                                                                            DOUBLE MECHANICAL SEALS
                                                                            SUBMERGED  FILL  LINES
0.0610 L6/MM3TU GAS
0.0430 LB/T'MBTU PROPANE
       LCM NOX BURNERS W/F.G.
4.0000 LB/Ii;i3TU G\5
1.5000 LB/M:'STU PROPANE
       FLUE G4S MONITORING
                                                                                                    MONITOR
PAGE G- 463

-------
(CONTINUED) HILL PETROLEUM CO.
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
I BASIS
PCT EFF
HEATER, HYDROTREATER CHARGE
HEATER, HYDROTREATER STABLIZER
REBOILER, REFORMER STABILIZER
REBOILER, STABILIZER (GASOLINE)
BOILER
                                     18.29 MMBTU/H
                                     13.58 MMBTU/H
                                     13.93 MMBTU/H
                                     15.49 MMBTU/H
                                     78.15 MMBTU/H
                     NOX       0.0610 LB/MMBTU
                                      LOW HOX BURNERS W/F.G. MONITOR
                     CO        4.0000 LB/MMBTU
                                      FLUE GAS MONITORING

                     NOX       0.0610 LB/MMBTU GAS
                               0.0430 LB/MMSTU PROPANE
                                      LOW NOX BURNERS W/F.G. MONITOR
                     CO        4.0000 LB/KM3TU GAS
                               1.5000 LB/MMBTU PROPANE
                                      FLUE GAS MONITORING

                     NOX       0.0610 LB/MMBTU GAS
                               0.0430 LB/NC3TU PROPANE
                                      LCW t.'OX BURNERS W/F.G. MONITOR
                     CO        4.0000 LB/MMBTU GAS
                               1.5000 LB/MM3TU PROPANE
                                      FLUE GAS MCMITORING

                     NOX       0.0610 LB/MM3TU
                                      LOU NOX BURNERS W/F.G. MONITORS
                     CO        4.0000 LB/MMBTU
                                      FLUE GAS MONITORING

                     NOX       0.1000 LB/MMBTU GAS
                               0.1100 LB/MfSTU PROPANE
                                      Ley NOX BURNERS W/F.G. MONITOR
                     CO        4.0000 LB/f"l3TU GAS
                               1.5000 LB/?":BTU PROPANE
                                      FLUE GAS MONITORING
NOTES 	
THE SOURCE WILL OPERATE CONTINUOUSLY, 6640 HRS/YR. ALL CONTROL STRATIGES ARE CONSIDERED BACT.
 (*)  INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

 PAGE G- 464
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEW STATUS;  04/01/1933
                ID NUMBER LA-0031
                                                                     SC'J-CE TYPE CODE
                                                                                         5.6

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/23/1984
 SOURCE  TYPE/SIZE—         PETROLEUM REFINING - ENTIRE OPERATION


 COMPANY NAME/SITE  LOCATION  MIAMI VALLEY REFIN. CO.
                                                                                            AURORA, IN
DETERMINATION  IS BACT FOR A NEW SOURCE.
PERMIT NO. PC(15)1485
DETERMINATION  MADE BY       INDIANA APCD
                             (AGENCY)
                     FRANK PROFIT
                  (AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE—  01/07/81
                                       ESTIMATED DATE OF START-UP—
                                       (317)-633-C664
                                           C PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS                                   ... & BASIS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
FBC COAL FIRED BOILER
NOTES
                                  50000.00 BTU/H
                                                           PM        0.0600 LB/MM8TU
                                                                            MULTICLONE « BAGHOUSE
                                                           S02       0.1400 LB/MM3TU
                                                                                       99.00
<*) INDICATES DATUM WAS TRUNCATED FOR THIS  TABLE.

PAGE G- 465
                                                                INITIAL  REVIEW  POST STARTUP
                                                  REVIEW  STATUS:   04/01/1933
                                                      ID NUMBER  IN-0009
                                                                                                           SO'JRCE  TYPE CODE    5.6

-------
                                             APPENDIX  — DETAILED  SOURCE  LISTING
                                                                                                                        05/32/1984
SOURCE TYPE/SIZE—
                            PETROLEUM REFINING -  ENTIRE  OPERATION
                                                                                              10.00 MBPSD
COMPANY NAME/SITE LOCATION  MITCHELL ENERGY
                            HWY 380, 2 MI W OF  BRIDGE  PORT
                                                      BRIDGEPORT,  TX
                                                                                    WISE  COUNTY
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT NO. (REGION FILE NO.) PSD-TX-139
DETERMINATION MADE BY       EPA REGION VI
                             (AGENCY)
                         JOHN  BUNYAK
                      (AGENCY  CONTACT  PERSON)
                                                            DATE  OF  PERMIT  ISSUANCE—   07/24/81
                                                            ESTIMATED  DATE  OF  START-UP—
                              ( PHONE )
PROCESSES SUBJECT
TO THIS PERMIT
HEATERS, 2


BOILER


FLARE

THROUGHPUT
CAPACITY
21.34 MMBTU/H


12.55 MMBTU/H




POLLUTANT
EMITTED

VOC


VOC


VOC
EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

0.0030 LB/MM3TU
EFFICIENT OPERATION

0.0030 LB/MM3TU
EFFICIENT OPERATION

0.0460 LB/MMBTU
... & BASIS
... PCT EFF

BACT


BACT


BACT
MALTHA STORAGE TANKS,  2
KEROSENE STORAGE TANKS,  Z
DIESEL STORAGE TANKS,  2
                                                                           EFFICIENT OPERATION
                                  10000.00  B3L  EA
                                  10000.00  BBL EA
10000.00 BBL EA
                                                          VOC
                                                          VOC
                                                          VOC
0.3700 LB/MM3TU
       DOUBLE SEALS

0.1600 LB/MMBTU
       DOUBLE SEALS

0.1200 LB/MMBTU
       DOUBLE SEALS
                                                                                                                            BACT
                                                                                                                            BACT
                                                                                                                            BACT
PAGE G- 466

-------
 (CONTINUED)  MITCHELL  ENERGY
 PROCESSES SUBJECT
 TO THIS PERMIT
    THROUGHPUT
     CAPACITY
POLLUTANT    EMISSION LIMITS                                   . .. « BASIS
 EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
 RESIDUE  STORAGE  TANKS


 PROCESS  DRAINS


 VALVES & FLANGES


 PUMP  SEALS


 CRUDE UNLOAD


 PRODUCT  UNLOAD
10000.00 BBL EA
                         VOC        0.0100 LB/MM8TU
                                          DOUBLE  SEALS

                         VOC        0.1600 LB/MMBTU
                                          MAINTENANCE  PROG.

                         VOC       11.7000 LB/MMBTU
                                          MAINTENANCE  PROG.

                         VOC        4.1700 LB/MMBTU
                                          MAINTENANCE  PROG.

                         VOC        Z.6200 LB/MMBTU
                                          MAINTENANCE  PROG.

                         VOC        1.4800 LB/MM3TU
                                          MAINTENANCE  PROG.
                                                                     BACT
                                                                     BACT
                                                                     BACT
                                                                     BACT
                                                                     BACT
                                                                                                                             BACT
NOTES
(*) INDICATES DATUM WAS TRUNCATED FOR  THIS TABLE.

PAGE G- 467
                                                                   INITIAL REVIEW  POST STARTUP
                                                      REVIEU STATUS;  04/01/1933
                                                      ID NUMBER TX-0050
                                                                                                           SOURCE  TYPE CODE    5.6

-------
                                             APPENDIX —  DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE	         PETROLEUM REFINING - ENTIRE OPERATION                             26.30 T/D


COMPANY NAME/SITE LOCATION  SOUND REFINING,  INC.                                            TACOMA, WA 9S422
                            2628 MARINE VIEW DRIVE


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—  10/17/83
PERMIT NO. N/C 2445                                                                            ESTIMATED  DATE OF  START-UP--   1984
DETERMINATION MADE BY       PUGET SOUND APCA               HARRY  MATTERS                       (206 )-344-7334
                             (AGENCY)                  (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT       POLLUTANT    EMISSION LIMITS                                    ...  t  BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT  OR  PROCESS  MODIFICATION  ...  PCT EFF


RECOVERY PLANT, SULFUR               26.30 T/D
                                                           S02       75.0000  PPM
                                                                            SEE  NOTE  91


NOTES 	
USIT 150 ALSO SUBJECT TO THE REQUIREMENTS OF 40 CFR  PART  60, SUBPART J  AND PSAPCA LETTER  DATED 10/17/83.

NOTE SI 	 SOUR WATER STRIPPER, AMINE STRIPPER, CLAUS UNIT, BEVIN TAILGAS CATALYTIC  UNIT,  STRETFOSD UNIT
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.
PAGE' G- 468
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS:  04/13/19S4
                                                     .TO NUMBER WA-0010
                                                                                                           SOURCE  TYPE  CCDE
                                      5.6

-------
                                             APPENDIX ~ DETAILED SOURCE  LISTING
 ===========	=	     _  _                                                                  05/22/1984


 SOURCE  TYPE/SIZE	          PETROLEUM REFINING - ENTIRE OPERATION                            9010.00  BPD
                            ---	-_..___	_«_	_______	- — _-_-__«_	______	__	__	„_	__«.._..__-,	_	__«____«

 COMPANY NAME/SITE  LOCATION   SOUND REFINING, INC.                                             TACOMA,  WA 9842?
                             2628 MARINE VIEW DRIVE
                                       '•	

                       OR * NEW SOURCE'                                                        DATE  OF PERMIT  ISSUANCE-  10/17/83
  PTCDMTU™™ M»r                                                                             ESTIMATED DATE  OF  START-UP—    1984
 DETERMINATION MADE BY        PUGET SOUND APCA               HARRY MATTERS                       (206 >-344-733
-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE	         PETROLEUM REFINING - ENTIRE OPERATION


COMPANY NAME/SITE LOCATION  SUNLAND REFIN. CORP.                                       BAKERSFIELD,  CA


DETERMINATION IS LAER FOR A MODIFIED SOURCE.                                                   DATE  OF PERMIT  ISSUANCE—  09/22/60
PERMIT NO. SJ-79-22                                                                            ESTIMATED  DATE  OF  START-UP-
DETERMINATION MADE BY       EPA REGION IX                  DAVID  SOLOMON                       (415)-454-8066
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... 4 BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT OR  PROCESS  MODIFICATION   ... PCT  EFF
STORAGE TANKS
LOADING RACKS
TANK TRUCKS
VALVES/FLANGES/PUMPS/COMFRESSORS
WORK WATER SEPARATOR
SUMP
                                                          voc
                                                          voc
                                                          voc
                                                          voc
                                                          voc
                                                          voc
        DOUBLE SEAL INTERNAL FLOATING ROOF
        OR VAPOR RECOVERY

30.0000 MG/L OF PRODUCT
        CARBON ABSORPTION SYS
                                                                           TRAILER TANKS TO BE  LEAK TIGHT
                                                                            FUGITIVE  I«M PROGRAM
                                                                           REQUIRED TO BE COVERED
                                                                           REQUIRED TO BE COVERED
PAGE G- 470

-------
 (CONTINUED) SUNUND REFIN.  CORP.
 PROCESSES SUBJECT
 TO THIS PERMIT
THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... $ BASIS
 CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
 PROCESS TURNAROUNDS
 VACUUM DEVICES
 PRESSURE  RELIEF  VALVES
 COMBUSTION SOURCES
 SULFUR RECOVERY  PLANT
                                                           VOC
                                                           VOC
                                                           VOC
                                                           S02
                                                           NOX
                                                           S02
                                                                            VENT DEPRESSURED & PURSED TO FUEL GAS SYS
                                                                            VENTED TO FUEL GAS SYS
                                      VENTED TO FLARE SYS & INCINERATED

                               0.0300 GR/DSCF H2S
                              50.0000 PPM 3X 02
                                      LOW NOX BURNERS
                                      NON-CATALYTIC AMMONIA INJECTION

                               1.0000 LB/H
                                                                                                                             LAER
LAER
BACT
                                                                                                                             LAER
NOTES  	
AWAFOR COLLECTION SYS MUST BE VAPOR TIGHT.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS  TABLE.

PAGE G- 471
                                                               INITIAL REVIEW  POST STARTUP
                                                  REVIEW STATUS-'  04/01/19S3
                                                      10  NUMBER  CA-0003
                                                                                                           SOURCE TYPE CODE    5.6

-------
                                             APPENDIX  — DETAILED  SOURCE  LISTING
                                                                                                                       05/22/1984
SOURCE TYPE/SIZE—
                            PETROLEUM REFINING - ENTIRE OPERATION
                                                                                           26000.00 BPSD
COMPANY NAME/SITE LOCATION  SWANN OIL CO.
                                                                                       CHESAPEAKE, VA
                                                                                                                CHESAPEAKE COUNTY
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT NO. 78VA04
DETERMINATION MADE BY       EPA REGION III
                             (AGENCY)
   EILEEN GLEN
(AGENCY CONTACT PERSON)
DATE OF PERMIT ISSUANCE—  03/30/81
ESTIMATED DATE OF START-UP—
(215)-597-8187
    (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
HEATER, CRUDE UNIT ATMOS.







HEATER, CRUDE UNIT VACUUM







HEATER, VISBREAKER


THROUGHPUT POLLUTANT
CAPACITY EMITTED
94.00 MMBTU/H
PM
S02

NOX

CO

18.00 MMBTU/H
PM
S02

NOX

CO

44.00 MMBTU/H
PM
S02
EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

9.0000 LB/H
18.0000 LB/H
0.57X S IN FUEL
36.0000 LB/H
2 STAGE + OFF-STOICH. CCMB.
3.0000 LB/H
GOOD OPERATION

2.0000 LB/H
3.0000 LB/H
S IN FUEL 0.37.
7.0000 LB/H
2 STAGE + OFF-STOICH. COK3.
1.0000 LB/H
GOOD OPERATION

4.0000 LB/H
8.0000 LB/H
. . . & BASIS
... PCT EFF

BACT
BACT

BACT

BACT


BACT


BACT

BACT


BACT
BACT
                                                                           S  IN  FUEL 0.37.
                                                          NOX       17.0000 LB/H
                                                                           2  STAGE  + OFF-STOICH. CCtB.
                                                                     BACT
PAGE G- 472

-------
                                                           CO        1.0000 LB/H                                             BACT
                                                                            GOOD OPERATION
PAGE G- 473

-------
(CONTINUED) SWANN OIL CO.
PROCESSES SUBJECT THROUGHPUT
TO THIS PERMIT CAPACITY
HEATER, NAPHTHA REFORMER 50.00 MMBTU/H







HEATER, NAPHTHA HYOROOESULFURIZ* 16.00 MMBTU/H







HEATER, DISTILLATE HYDRODESULFU» 16.00 MMBTU/H







BOILER, STEAM 29.00 MM3TU/H







EMERGENCY FLARE SYS


POLLUTANT
EMITTED

PM
SOS

NOX

CO


PM
S02

NOX

CO


PM
502

NOX

CO


PM
S02

NOX

CO


S02
NOX
EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION . . .

1.0000 LB/H
0.3000 LB/H
BURN REFINERY GAS <0.0063X S
11.0000 LB/H
2 STAGE + OFF-STOICH. COMB.
1.0000 LB/H
GOOD OPERATION

0.3000 LB/H
0.1000 LB/H
BURN REFINERY GAS <0.0063X S
4.0000 LB/H
2 STAGE + CFF-STOICH. COMB.
0.3000 LB/H
GOOD OPERATION

0.3000 LB/H
0.1000 LB/H
BURN REFINERY GAS <0.0063X 5
4.0000 LB/H
2 STAGE * OFF-STOICH. COM3.
0.3000 LB/H
GOOD OPERATION

0.5000 LB/H
0.2000 LB/H
BURN REFINERY GAS <0.0063X S
7.0000 LB/H
2 STAGE « STOICHICMETRIC CCttS
0.6000 LB/H
GOOD OPERATION

0.0100 LB/H
0.2000 LB/H
& BASIS
PCT EFF

BACT
BACT

BACT

BACT


BACT
BACT

BACT

BACT


BACT
BACT

BACT

BACT


BACT
BACT

BACT

BACT


BACT
BACT
PAGE G- 474

-------
 (CONTINUED) SWANN OIL CO.
PROCESSES SUBJECT
TO THIS PERMIT
POWER PUNT., TANKER




THROUGHPUT POLLUTANT
CAPACITY EMITTED
VARIABLE
PM
S02
NOX
CO
EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

14.0000 LB/H
311. 0000 LB/H
64.0000 LB/H
1.0000 LB/H
... * BASIS
. . . PCT EFF

BACT
BACT
BACT
BACT
                                                          S02
                                                                   14.0000 LB/H
                                                                                                                            BACT
NOTES 	

SC2 EMISSIONS FROM ATMOSPHERIC HEATER,  VACUUM HEATER, t VISBREAKER HEATER SHALL NOT EXCEED THE SPECIFIED EMISSION RATES ON A 2
  -     ROLLING AVERAGE BASIS.
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.


PAGE G- 475
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS;   04/01*933
                                                     ID NUMBER VA-0002
                                                                                                          SOURCE TYPE CODE
                                                                                                                              5.6

-------
                                             APPENDIX ~ DETAILED SOURCE LISTING
                                                                                                                        05/22/1984




SOURCE TYPE/SIZE—-         PETROLEUM REFINING - ENTIRE OPERATION                            200.00 MBPSD
                           		_ -—	——	-	

COMPANY NAME/SITE LOCATION  VIRGIN ISLANDS REFINERY CORP.                                ST. CROIX, VI
                            ESTATE BETHLEHAM
                           — „ __ __.—_._ _ ._«_.._ _.. . _~_~ — — — —. — — — ___ — » — «,———— — • — •. — -.—-. — •— _.__~__ _——.— -.— — — — —— — — —_—__—™—_ »._—•.»-.— «•-»——«. — —.,— — — — «•••—i —

DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE—  09/04/81
PERMIT NO. NOKE                                                                                ESTIMATED DATE OF START-UP—   1985
DETERMINATION HADE BY       EPA REGION II                  ED NOWAK                            (212J-264-8690
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... * BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... FCT EFF
BOILERS, FOSSIL FIRED, 3
                                 175000.00 BBL/D
HYDROGEN PLANT
CO       14.0000 T/YR
                 GOOD BOILER OPERATION
VOC       3.0000 T/YR
                 GOOD BOILER OPERATION
NOX       0.2000 LB/MtlBTU GAS
          0.3000 LB/MMBTU OIL
PM        0.3520 LB/MtlBTU
S02      20.0000 PFM H£S GAS
          0.3300 X S BY WT, OIL

CO      105.0000 T/YR
                 GOOD BOILER OPER./NO FUEL OIL
VOC      19.0000 T/YR
                 GOOD BOOILER OPER./NO FUEL OIL
NOX    1088.0000 T/YR
                 STOICHIO. COKBST./NO FUEL OIL
PM        0.3520 LB/tir.BTU
S02       3.0000 T/YR
                 NO GAS<.1 GR/DSCF H2S
BACT

BACT

BACT

BACT
BACT


BACT

BACT

BACT

BACT
BACT
PAGE G- 476

-------
 (CONTINUED) VIRGIN ISLANDS REFINERY CORP.
PROCESSES SUBJECT
TO THIS PERMIT
PROCESS HEATERS








FCC UNIT








SULFUR RFrnVFDY Dl AWT
THROUGHPUT POLLUTANT
CAPACITY EMITTED

CO

voc

NOX

PM
S02
175000.00 BBL/D
CO
VOC

NOX

PM

S02

EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

369.0000 T/YR
GOOD BOILER OPERATION
73.0000 T/YR
GOOD BOILER OPER.
0.3000 LB/MMBTU OIL
0.2000 LB/MMBTU ALT. FUELS
0.3520 LB/MMBTU
3683.0000 T/YR
OIL<.33XS WT/ALT<.1GR/DSCF H2S
565.0000 T/YR
3247.0000 T/YR
GOOD BOILER OPER.
0.3000 LB/MMBTU OIL
0.2000 LB/MMBTU ALT. FUELS
1.0000 LB/MLB COKE BURN
0.1000 LB/MMBTU SUPP. OIL
79.0000 T/YR
OIL<.33XS WT/ALT<.1GR/DSCF H2S
... 8 BASIS
... PCT EFF

BACT

BACT

BACT

BACT
BACT

NSPS
BACT

BACT

LAER

NSPS

PETROLEUM LIQUID STORAGE TANKS
CO       29.0000 T/YR
                 GOOD HEATER OPERATION
VOC      35.0000 T/fR
                 GOOD HEATER OPERATION
NOX       0.3000 LB/MMBTU OIL
          0.2000 LB/MMSTU ALT.
PM        0.3520 LB/MMBTU
S02     365.0000 T/YR
                 CLAUS SYS. W/ 3 UNITS
                 OIL<.33S WT/ALT<.1GR/DSCF H2S

VOC     937.0000 T/YR
                 FLOATING ROOF TANKS
BACT

BACT

BACT

BACT
NSPS



NSPS
PAGE G- 477

-------
(CONTINUED) VIRGIN ISLANDS REFINERY CORP.
PROCESSES SUBJECT
TO THIS PERMIT
PUMPS, SEALS, VALVES, FLANGES

MARINE LOAD t UNLOAD FACILITY


THROUGHPUT POLLUTANT
CAPACITY EMITTED

VOC

VOC

EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION . . .

177.0000 T/YR

64.0000 T/YR
SEALS
& BASIS
PCT EFF

BACT

SIP

INCINERATOR, MULTI-CHAMBER
API WASTE OIL SEPERATOR
     CO               NONE
                      GOOD OPERATION
     NOX              NONE
                      GOOD OPERATION
     PM        0.3000 LB/H

     VOC     436.0000 T/YR
                      FIXED COVER/FOAM SPHERES
BACT

BACT



NSPS
NOTES
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 478
                                                                                                     INITIAL REVIEW  POST STARTUP
                                                                                        REVIEW STATUS;  04/01/1933
ID NUMBER VI-0001
                                                     SOURCE TYPE CODE
                                                                         5.6

-------
                                             APPENDIX  —  DETAILED  SOURCE LISTING
 	                                                                                                                     05/22/198*
 	= = - = = = = = - = = = = = = = = = = = = = = = = = = = = = =: = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = == = = r = = = = = = = = = = = = = = = r = = = = = = = = = = = = r= = = r = r = = = =r = = = = = r = r = = r



 SOURCE TYPE/SIZE—          BULK TERMINALS
                            _-.__-_	-_-_-__.._.._..__....	-,._ — _..__„..	«._---_-.___,.__ _„__..___..___,._.„______	_______	«.-.__.__ —«.»_._«._„»«.«


 COMPANY NAME/SITE LOCATION  AMOCO OIL CO., GRANVILLE                                      MILWAUKEE, WI
                            	



                        °R * NEW SOURCE-                                                         DATE OF PERMIT ISSUANCE-  06/23/80
 nrrroMT   T"064                                                                     ESTIMATED DATE OF START-UP-   1981
 DETERMINATION MADE BY       WISCONSIN DNR                  ELIZABETH SPAETH                    (414)-257-4929
                              (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)

 ; = = = = = = = = = = r = = = = r = === = r= = = = = r==r^= = = = = ==r=== = = rrrr = == = = ===== = = = = = = ==r = = = = = i: = = = = = = = = = = = =: = = = = = = = = = = = = = = = = = = == = = = = = _ = = = = = = = = = = = -.-___-


 PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ...» BASIS
 TO THIS PERMIT                         CAPACITY           EMITTED             CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
  ""                                                     •	—	—	—	

 TERMINAL                         214494.00 MGAL GASOLI*

                                                           VOC       30.0000 MG/L                                             LAER
 _.cnMTl A                                                                      FLOAT ROOF & VAPOR RECOVERY SYS.                 97.00
 TERMINAL                          71358.00 MGAL 82 OIL
                                                           VOC      80.0000 MG/L
                                                           VOC       30.0000 MG/L                                             LAER


 NOTES 	

 OFFSET OBTAINED BY CLOSING JONES ISLAND TERMINAL, EXTRA EMISSIONS  BANKED 41.55 TPY



















 , ,  ,                                                                                                  INITIAL REVIEW  POST STARTUP
 (*)  INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                          REVIEW STATUS:   04/01/1933


PAGE  G- 479                                            ID NUMBER WI-0005                                     SC'JSCE TYPE CODE    S~7

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                         05/23/1984
SOURCE TYPE/SIZE—         BULK TERMINALS


COMPANY NAME/SITE LOCATION  ASHLAND PETROLEUM CO.                                        COVINGTON, KY  41015
                            30TH « JONES ST.                                                                          KENTOH COUNTY
                           _	—	—	—	— ——	•_____„«,_„ — _-._-. — — ». — _-. — -. — -. — — — — -.-. — — — — — — — — —	— —	— — — — — —	„_ — — — — — _ —	._„_., — _ — _-. — — _

DETERMINATION IS BACT                                                                          DATE OF  PERMIT ISSUANCE—   04/01/81
PERMIT NO. C-81-37                                                                             ESTIMATED  DATE OF START-UP--   19S1
DETERMINATION MADE BY       KENTUCKY DAPC                  BILL DILLS                          (502)-564-33S2
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ...  * BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS  MODIFICATION  ...  PCT EFF
— „ — _ — _ — .. — __ — — — — .. — — _ H — v_ v — _ — — _.*— — _ _ _ »_ ____________ — — .. — .. — _ — w _ v_ .»_ .• «*»b •-_ — — — — w — — — « — v —— — — «.__> — — —. — • — »— — • — — — — — — — — — — — — -, — — -. — -. — — — — — —. — — —. — — — • — —

BOTTOM FILL LOADING RACK           3000.00 GAt/MIN
                                                           VOC      80.0000 MG/L GROUND LOADING
                                                                            CARBON ABSORPTION


NOTES -	
THIS PERMIT GRANTED UNDER A VOC BUBBLE REQUEST TO AtlEVATE RETROFITTING EXISTING TANKS W/FLOATING ROOFS.  PERMIT N/A  TO  BACT/LA
ER.
THIS BUBBLE SET THE ALLOWABLE AT 30000. MG/L
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.
                                                                                                       INITIAL  REVIEW  POST STARTUP
                                                                                         REVIEW  STATUS:   OV01/19S3     02/13/1934
PAGE G- 480
                                                      ID NUMBER KY-0019
                                                                                                            SCL'SCE  TYPE  CODE    5.7

-------
                                             APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                         05/22/198*
 SOURCE TYPE/SIZE—         BULK  TERMINALS                                           -     476000.00 BBL

 COMPANY NAME/SITE LOCATION  BAYTANK  INC., HOUSTON                                         SEABROOK, TX
                                                                                                                     HARRIS COUNTY
                                                                                               DATE °F PERMIT ISSUANCE-  02/12/82
 DETERMINATION MADE BY       TEXAS ACB                      STUART KEIL                         ff I'           °?
                              (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)
                                      THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... t BASIS
         PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS t^OIFICATION  . . . PCT EFF

 STORAGE  TANKS, 49                          CAPACITY VA*
                                                           V°C                                                               BACT
                                                                            FLARING EMIS., SEE NOTE 2                        99 00
 WASTE WATER SEPERATOR, SEE NOTE»                                            "AT' W/>°'5 PSIA ^ FRESS'
                                                           VOC                                                               BACT
                                                                            COVERS W/VENTS TO FLARES                         99.00
NOTES
RHTEuTTu onnIEnn'AIER SEPARATOR INCLUDES Z DECANTERS S DOUBLE SKIMMER SYS. NOTE 2 - ALSO MATERIALS WITH < 0.5 PSIA VAP. PRESS
BUT WITH ODGR OR TOXICITY EFFECTS ARE REQUIRED TO MEET THESE EQUIPMENT STANDARDS / TO USE ADSORBERS.
PAGE G- 431                                           ro HurfBER  TX.0108

-------
                                              APPENDIX  —  DETAILED SOURCE LISTING
                                                                                                                          05/22/1984



SOURCE TrPE/SIZE-—          BULK  PLANTS                                                         1.00 MMGAL/D


COMPANY NAME/SITE  LOCATION   TIME  OIL  CO.                                                   RICHMOND, CA
                            — — — — — — — —— — — — — — — — — — ——.» — —— — — •— — • — _ — _ ««.,.... _____<__ _.. w .__. __._ v_ _ __.. ««..._..„_ __ _«..__«....*..._._ _ — _ — _ — _«___.- — _ _~

DETERMINATION IS BACT  FOR A NEW SOURCE.                                                         DATE OF PERMIT ISSUANCE—  12/23/80
PERMIT MO. 27611                                                                                ESTIMATED DATE OF START-UP—   1981
DETERMINATION MADE BY        BAY AREA  AQMO                  KELLY WEE                           (415 )-771-6000
                             (AGENCY)                  (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... 4 BASIS
TO THIS PERMIT                         CAPACITY           EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
— — —	— — — — — — -. — — — — —— — — — — — — .. — — .. — _-.._ — __._.._.._«._	— — — — — — — — — — — — — — — — — — — — — —.^ — ~^ — ~~ — — ~ —— — ^_ —— — —_ — _._ —____.-._-._..__._„.__.__._._,__.__.._.,._„.._.».__,.	

GASOLINE BULK LOADING  RACK            1.00 MMGAL/D
                                                           VOC       91.0000 LB/D                                             BACT
                                                                     90.0000 LB/MMGAL
                                                                             CARBON ADSORPTION                                93.60


NOTES 	
SOURCE TEST *83062. FILE A  350-004
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 462
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS:  04/19/1934
                                                      ID NUMBER CA-0051
                                                                                                            SOURCE TYPE CODE    5.6

-------
                                              APPENDIX  — DETAILED  SOURCE LISTING
 = ---_--__..._____._.____.____..______		                                                05/22/1984


 SOURCE TYPE/SIZE—         STORAGE OF PETROLEUM LIQUIDS


 COMPANY NAME/SITE LOCATION  MCKESSON CHEMICAL CO.                                             TULSA, OK
                            -. .. «. _ _ — _ — ••__.• ». _.».. _ ___ „.'"• —— — — — -• — — — •- — — •- — — •-•• — — — .•».— •....__._„,.— _^.___ — __ — — __<1-r_ _, _.

 DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE OF PPpMTT  TWIturF     in/*,/*,
 PERMIT NO.  SEE NOTE                                                                                E OF PERf1IT  ISSUANCE—   10/01/81
 DETERMINATION MADE BY       TULSA CITY-COUNTY HEALTH DEPT  BILL GIBBONS                        "IJ1SS-55S  ^ START-UP"
                              {AGENCY)                   (AGENCY CONTACT PERSON)                    (PHCHE)


                                       THROUGHPUT        POLLUTANT    EMISSION LIMITS                                        4  BASIS
 --_--._„.„	             CAPACITY          EMITTED             CONTROL EQUIPMENT OR PROCESS MODIFICATION   !!!pCTEFF
                        ~~~"~~"*""~™'~*""  ""  "~         ~"	~	—	— — — — —	— — ,.__-___	,	^._»™_	„ ___ — ___ __w	__.	— _ — _.,__	^ —	
 DRUM  FILLING FACILITY
                                                            VOC
                                                                              VAPOR  RECOVERY LOOP                               90.00

 NOTES		-
                                                                                                                       CAPACITY
(*) INDICATES DATL'M WAS TRUNCATED FOR THIS TABLE.
PAGE G- 483
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS:  OV01/19S3
                                                       ID  NU!^3ER CK-0011
                                                                                                             SOL"CE TYPE CODE    5.9

-------
                                             APPENDIX  — DETAILED SOURCE  LISTING
                                                                                                                       05/22/1984



SOURCE TYPE/SIZE—         TRANSPORT « MARKETING -  PETROLEUM  PRODUCTS


COMPANY NAME/SITE LOCATION  COLUMBIA GAS TRANSMISSION  CORP.                            SUGAR GROVE, OH


DETERMINATION IS BACT FOR A NEW SOURCE.                                                       DATE OF PERMIT ISSUANCE--  04/13/81
PERMIT NO. 0123000137                                                                         ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY       OHIO EPA CD                   GEORGE DEMIS                        (614>-864-3195
                             (AGENCY)                  (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                   ... * BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF


NAT. GAS FIRED I. C. ENGINES
                                                          NOX      5.0000 G/HP-H
                                                                           ENGINE DESIGN
                                                          CO        2.0000 G/HP-H
                                                                           ENGINE DESIGN
                                                          VOC      0.3000 G/HP-H
                                                                           ENGINE DESIGN


NOTES 	
(«) INDICATES DATUM WAS TRUNCATED FOP THIS TABLE.

PAGE G- 484
                                                                                                     INITIAL REVIEW  POST STARTUP
                                                                                        REVIEW STATUS--  04/01x933
ID NUMBER OH-0024
                                                     SOURCE  TYPE CCDE   5.11

-------
                                             APPENDIX — DETAILED SOURCE LISTING
 	                                                                                     05/22/1984


 SOURCE  TYPE/SIZE—         TRANSPORT 8 MARKETING - PETROLEUM PRODUCTS
                           ~~— —• — — — — •-— — — — — — — — — — — —.— _ — —«..— _ — _.. —*.^*»_*»~«WMH.>T« __-.______ w«._ • __-,_,»„ •-•.•_«» — _— —_—.» — —_»_..-.^__—. — .B_.,-._ — _____„ —

 COMPANY NAME/SITE  LOCATION  CRYSEN REFINING, WESTERN DIV.                              WOODS CROSS, UT
                                                                                                                      DAVIS COUNTY
                           	

 CFDHTTI^TI°N IS                                                                               DATE OF PERMIT ISSUANCE—  11/12/82
 n^rnM      L                                                                                  ESTIMATED DATE OF START-UP—   1933
 DETERMINATION MADE BY       UTAH BAQ                       DONALD ROBINSON                     (801 )-533-6108
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



 PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ...» BASIS
 TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  !.. PCT EFF


 NAPTHA  TANK, 2                   365000.00 BBL/YR EA
                                                           VOC
                                                                            INTERNAL FLOATING ROOF

 NOTES 	
(*) INDICATES DATUM WAS TRUNCATED FOR  THIS TABLE.

PAGE G- 485
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS--  04/01/1933    22/13/1964
                                                     ID NUMBER UT-0027
                                                                                                           SOURCE  TYPE COCE    5.11

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                         05/22/1984
SOURCE TYPE/SIZE	         TRANSPORT t MARKETING - PETROLEUM PRODUCTS                     22600.00  GAL/D
                           		_ __	—	_ — -. — _. — —	_____ — _.-._. — — -. — — -. — — _ — —	_«__	— __ — — — —	


COMPANY NAME/SITE LOCATION  DEPT. OF THE NAVY                                       CORPUS CHRIST!,  TX
                                                                                                                      NUECES COUNTY
DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE  OF  PERMIT ISSUANCE—  09/15/32
PERMIT NO. X3S18                                                                               ESTIMATED  DATE OF START-UP—
DETERMINATION MADE BY       TEXAS ACB                      STUART KEIL                         (512)-451-5711
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE )
PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                    ...  4 BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT  OF}  PROCESS MODIFICATION  ...  PCT EFF
	_„___.,_.._.. _.,_-.__,_._.._ —	— — _ — _-. — »_.,	•«.„__._ — -» —— — — •^•™ —— — — «»«.•. — — -. — — — — — —— — — — — — — — — — — — — — —— — •-•^ — — —— — — — —— — —	—	— — — —	— — »•-. — -. — — — — — — —

LOADING RACK/STORAGE TANKS, 2      6000.00 BBL
                                                           VOC              NIL EMISSIONS
                                                                            DISPLACED VAPORS ROUTED TO FLARE                 99.
-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1934
 SOURCE TYPE/SIZE—          TRANSPORT ft MARKETING - PETROLEUM PRODUCTS


 COMPANY NAME/SITE  LOCATION   NORTHERN ALASKAN PIPELINE
                                    2000.00 MMCFD
                                                                                                    AK
 DETERMINATION IS BACT  FOR A NEW SOURCE.
 PERMIT  NO.  (REGION  FILE NO.) PSD-X81-03-09
 DETERMINATION MADE  BY       EPA REGION X
                             (AGEKCY)
   PAUL BOYS
(AGENCY CONTACT PERSON)
DATE OF PERMIT ISSUANCE—  02/23/81
ESTIMATED DATE OF START-UP—
(2C6)-442-1193
    (PHCHE)
 PROCESSES SUBJECT
                                      THROUGHPUT
                                       CAPACITY
POLLUTANT    EMISSION LIMITS
 EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION
                        ...  « BASIS
                        ...  PCT EFF
MAINLINE COMPRESSOR TURBINE
REFRIG. COMPRESSOR TURBINE
ELECT. GEN. TURBINE
GLYCOL HEATER MISC.
NOTES
   NOX     150.0000 PPM
            80.0000 KG/H
                    DRY CONTROLS

   NOX     150.0000 PFM
            38.0000 KG/H
                    DRY CONTROL

   NOX     150.0000 PPM
            15.0000 KG/H
                    DRY CONTROL

   NOX      43.0000 NG/J
             4.0000 KG/H
                    LCU NOX BURNERS
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                    vn
                    Tc Ar?
                                  STATION'  7 WILL  BE  BUILT  ALONG  PIPELINE.  ALSO TOTAL LIMIT FOR  EACH STATION OF 175 KG/HR OR 1
(*) INDICATES DATUM WAS TRUNCATED FOR  THIS  TABLE.

PAGE G- 487
                                              INITIAL REVIEW  POST STARTUP
                                 REVIEW STATUS;   04/01/1933
                                                     ID NUflBER  AK-0002
                                                                                                           SOURCE  TYPE  CODE    5.11

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE	         TRANSPORT t MARKETING - PETROLEUM PRODUCTS                       933.00  MEBL/D


COMPANY NAME/SITE LOCATION  NORTHERN TIER                                                         ,  AK


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE  OF  PERMIT  ISSUANCE—  09/14/81
PERMIT NO. (REGION FILE NO.) PSD-X31-14                                                        ESTIMATED  DATE  OF  START-UP-
DETERMINATION MADE BY       EPA REGION X                   PAUL BOYS                           (206)-442-1193
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... * BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS  MODIFICATION   ... PCT  EFF





NOTES 	
FOR PERMIT CONDITIONS, SEE ATTACHMENT, ALL ARE BASED ON TECHNOLOGY AND ECONOMICS.
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 483
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS;  04/01/1933
                                                      ID NUMBER AK-0001
                                                                                                          SCL'SCE TYPE CC3E   5.11

-------
                                              APPENDIX  ~ DETAILED  SOURCE LISTING
 			     _                                                                                         05/22/1984
                                    = :: = = = = = :::: = = :: = = = = = = = = = = === = = = = = = = = = = r = = = = r===r=r=r = = ====rrr========rr===r==r==r===r= === = = r=r = = = =


 SOURCE TYPE/SIZE	         NATURAL GAS/GASOLINE PROCESSING PLANTS                         55000.00 HP


 COMPANY NAME/SITE LOCATION  AMERADA HESS                                                     TULSA  TX

                                                                                                   '
                                               ""   """"  — — ——— — — — —— — — —— — — — —•»—•-.— -.	—«.—_•_.	_	„_,.

 DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE OF PEBMIT TSSUANrp
 PERMIT HO.  (REGION FILE  NO. ) PSD-TX-328                                                        S?in!ra ?ATE 0?S?ART"uP
 DETERMINATION MADE BY       EPA REGION VI                  JOHN BUNYAK                          "™-76?-?W    START-UP"
                              (ASENCY)                   (AGENCY CONTACT  PERSON)                     (PHONE)

                                      - = = = = = r = s = = r = r = -p*	
                                                             •	= - = = = = = = -== = = = - = = - = ===== = = = = = ===rr = r^ri:r = r = = r = =

                                       THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                   ...  t BASIS
                                        CAPACITY          EMITTED            CONTROL  EQUIPMENT OR PROCESS MODIFICATION  ...  FCT EFF
 ENGINE, NAT. GAS, COMPERSSOR, 3*   1600.00 HP
                                                           NOX      10.6000 G/HP-H
                                                                            ADJUSTED AIR FUEL RATIO
                                                           VOC      53.0000 T/YR
                                                                            NORMAL EQUIP. OPERATION
                                                           CO        1.4000 G/HP-H
                                                                            NORMAL EQUIP. OPERATION
                                                           SOS       0.2500 T/YR
                                                                            NORMAL EQUIP. OPERATION
                                                           PM               TRACE
                                                                            NORMAL EQUIP. OPERATION
                                     BACT

                                     BACT

                                     8ACT

                                     BACT

                                     BACT
NOTES
(*) INDICATES DATUM WAS TRUNCATED F09 THIS TABLE.
PAGE G- 489
                                                      ID  NUMBER TX-0017
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS:  04/01/1933
                  SOURCE TYPE CODE   5.12

-------
                                             APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                       05/22/1984
SOURCE TYPE/SIZE —
NATURAL GAS/GASOLINE PROCESSING PLANTS
                                                                                            250.00 MMCFO
COMPANY NAME/SITE LOCATION  AMOCO PRODUCTION
                                                                                            UINTA, WY
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT NO. CT-272
DETERMINATION M40E BY       WYOMING AQD
                             (AGENCY)
                              BERNIE  DAILEY
                            (AGENCY  CONTACT PERSON)
DATE OF PERMIT ISSUANCE—  12/20/79
ESTIMATED DATE OF START-UP—   1983
(307)-777-7391
    (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
BOILER, GAS, 2 EA
HEATER, GAS
THROUGHPUT
CAPACITY
65.50 MMBTU/H
33.30 MHBTU/H
POLLUTANT
EMITTED
NOX
EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION . . .
0.2000 LB/MMBTU
DESIGN
t BASIS
PCT EFF
BACT
HEATER, GAS
INCINERATOR, SULFUR PLANT
                                      7.10 MMBTU/H
                               NOX       0.2000 LB/MMBTU
                                                DESIGN

                               NOX       0.2000 LB/MMBTU
                                                DESIGN

                               S02     311.5000 LB/H
                                                CLAUS S  CBA
                                                                                                                            BACT
                                                                                                                            BACT
                                                                                                                            BACT
                                                                                                                            93.60
NOTES 	
AN EXTENSIVE BACT ANALYSIS BASED ON ECONOMIC,  ENERGY,  & ENVIRONMENTAL  FACTORS COMPARING CLAUS-CBA TO CLAUS-SCOT WAS PERFORMED.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 490
                                                                                                     INITIAL REVIEW  POST STARTUP
                                                                                        REVIEW STATUS:
                          ID  NUMBER  WY-0008
                                                                               SOURCE  TYPE CODE   5.12

-------
                                              APPENDIX  — DETAILED  SOURCE LISTING
                                                                                                                         05/22/1984
 SOURCE TYPE/SIZE ---         NATURAL GAS/GASOLINE  PROCESSING  PLANTS                                   SEE NOTE


 COMPANY NAME/SITE LOCATION  AMOCO PRODUCTION CO.
                                                                                                                    BILLINGS COUNTY
                           * NE         -                                                         DATE Of PERMIT ISSUANCE-  01/12/83
 DETERMINATION MADE  BY        NORTH  DAKOTA SHD               GARY HELBLING                             --
                              (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)
TnTHr    FT                        THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                    . . .  g BASIS
TO THIS  PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ...  PCT EFF


INCINERATOR STACK                          SEE NOTE
                                                           S02              SEE NOTE                                          BACT
                                                                            CLAUS UNIT  « CBA                                  98.60
NOTES

     c
      nu,
      O"4 LIMIT OF 249 LB/H S02.
             T° BE CONSTRUCTED IN ™"EE STEPS. THE PLANT WILL PROGRESS FROM A 25 MMCF/D PLANT WITH  AN  EMISSION LIMIT OF 6? 25
               5° MMCF/D PUNT "ITH AN EMISSIOM LIMIT OF l««-5 LB/H S02 4 THEN TO A 100 KHCF/D  PLANT WITH  AN
                                                                                                      ^•JTTT \t DPVTFW   Pfr«;T  «5TAQTnD
<,*)_INOICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         KLVltn STATUS:  'o*/01/l?33    TObT5TARTUP

PAGE G- 491                                           ID K1JHBE3 no.0003                                     ^^l^CC3E~~~slll

-------
                                             APPENDIX —  DETAILED  SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE—         NATURAL GAS/GASOLINE PROCESSING PLANTS


COMPANY NAME/SITE LOCATION  ATW COMPANY                                               ISABELLA  TUP,  MI
                                                                                                                   ISABELLA COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE  OF  PERMIT  ISSUANCE—  04/28/83
PERMIT NO. 631-82B                                                                             ESTIMATED  DATE  OF START-UP—    1983
DETERMINATION MADE BY       MICHIGAN DNR                   LAURA OTWELL                         (517)-322-1333
                             (AGENCY)                  (AGENCY CONTACT  PERSON)                    (PHONE )



PROCESSES SUBJECT                     THROUGHPUT       POLLUTANT     EMISSION  LIMITS                                    ... t BASIS
TO THIS PERMIT                         CAPACITY           EMITTED            CONTROL EQUIPMENT OR PROCESS  MODIFICATION   ... PCT EFF


GAS SWEETENING AMINE FACILITY         2.30 MMCF/0
                                                           S02       24.0000 LB/H
                                                                           2  STAGE CAUST. SCRUBS..INCINERATOR              99.99


NOTES 	
RULE 403(4) OF THE MICHIGAN APC RULES REQUIRE BACT  ON ALL NEW SWEETENING FACILITIES. DETERMINATION IS BASED ON DETAILED  ECOS'CM
1C ANALYSIS AND EXPECTED EFFICIENCIES OF VARIOUS CONTROL  SYSTEMS.
                                                                                                     INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS'-  04/19/1964    03/13/1934

PAGE G- 492                                           ID NUMBER MI-0032                                    SOLACE TYPE CODE   5.12

-------
                                              APPENDIX — DETAILED SOURCE LISTING
 ======= = r=== = ::============!.___:._ = r-==-==5=====	                                            05/22/1984


 SOURCE TYPE/SIZE—         NATURAL GAS/GASOLINE  PROCESSING PLANTS                            60.00 MMCFD


 COMPANY NAME/SITE LOCATION  CHAMPLIN PETROLEUM                                                    t MY

                                                                                                                       UINTA COUNTY

 DETERMINATION IS BACT FOR A NEW SOURCF
 PERMIT NO. CT-515               SOURCE.                                                         DATE Qf pERMIT ISSUANCE_.  11/08/83
 DETERMINATION MAnF RY       uvnMTui- ir,n                                                         ESTIMATED DATE OF START-UP—
 utitKFUNAJIUN MADE BY       WYOMING AQD                     CHUCK  COLLINS                       (307)-777-7391
                              (AGENCY)                   (AGENCY CONTACT  PERSON)                     (PHONE)



                                       THROUGHPUT         POLLUTANT    EMISSION  LIMITS                                        ft BASIS
                                       CAPACITY           EMITTED             CONTROL EQUIPMENT  OR  PROCESS MODIFICATION  .".".'  PCT EFF
 COMPRESSOR,  2  EA
HEATER, GAS
TURBINE, 2 EA
                                    2250.00 HP
                                      3.75 MMBTU/H
                                    886.00 HP
NOX        4.0000  G/HP-H
                  DESIGN
CO         2.0000  G/HP-H
                  DESIGN
VOC        0.5000  G/HP-H
                  DESIGN
S02        0.8900  LB/H

NOX        0.2300  LB/MMBTU
CO         0.0200  LB/MH3TU
S02        0.3000  LB/H

NOX        1.0800  G/HP-H
                  DESIGN
CO         2.0000  G/HP-H
                  DESIGN
VOC        0.0100  G/HP-H
                  DESIGN
S02        0.5800  LB/H
BACT

BACT

BACT

BACT

BACT
BACT
BACT

BACT

BACT

BACT

BACT
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE 6- 493
                                           INITIAL REVIEW  POST STARTUP
                              REVIEW STATUS:
                                                      ID  NUMBER  WY-0005
                                                                                                           SOL'?CE TYPE CODE   5.12

-------
NOTES 	
S02 EMISSIONS LIMITS BASED ON FUEL S CONTENT OF LESS  THAN 20  GR/100  SCF.
                                                                                                     INITIAL REVIEW  POST STARTUP
I*) INDICATES DATUM WAS TRUNCATED FOR  THIS TABLE.                                        REVIEW STATUS:
PAGE G- 494                                          ID NUMBER WY-COC5                                    SOURCE TYPE CODE   5.13

-------
                                             APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                         05/22/198*
 SOURCE TYPE/SIZE	
                             NATURAL GAS/GASOLINE PROCESSING PLANTS
                                                                                              260.00 MMCFD
 COMPANY NAME/SITE LOCATION  CHAMPLIN PETROLEUM CO.
                             P.O.  BOX 310
                                                    CARTHAGE, TX
                                                                                                                     PONALA COUNTY
 DETERMINATION IS BACT FOR A MODIFIED SOURCE
 PERMIT NO.  TX-206
 DETERMINATION MADE  BY       EPA REGION VI
                              (AGENCY)
                     JOHN BUNYAK
                  (AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE—  01/11/60
                                       ESTIMATED DATE OF START-UP—
                                           )-767-1594
                                           (PHONE)
 PROCESSES SUBJECT
 TO  THIS  PERMIT
 I.  C.  ENGINE
 I. C. ENGINE, 2
I. C. ENGINE, 2
THROUGHPUT
 CAPACITY
                                    800.00 HP
                                   1050.00 HP EA
                                    730.00 HP EA
POLLUTANT    EMISSION LIMITS
 EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION
                     NOX      19.2000 LB/H
                              24.0000 LB/MHP-H
                                      CNTRL AIR/FUEL RATIO,  IGN TIM.

                     NOX      25.2000 LB/H EA
                              24.0000 LB/MHP-H
                                      CNTRL AIR/FUEL RATIO,  ISN TIM.

                     NOX      16.4000 LB/H
                              24.0000 LB/MHP-H
                                      CNTRL AIR/FUEL RATIO,  IGN TIM.
...  & BASIS
...  PCT  EFF
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
NOTES 	
MODIFICATION — INCREASED CAPACITY FROM 220 MMCFD TO 260 MMCFD.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.
PAGE G- 495
                                                               INITIAL REVIEW  POST STARTUP
                                                  REVIEW STATUS--  04/01/1933
                                                      ID NUMBER TX-0069
                                                                                                           SOURCE  TYPE  CODE    5.12

-------
                                             APPENDIX — DETAILED  SOURCE  LISTING
                                                                                                                        05/22/198*
 SOURCE TYPE/SIZE —
                             NATURAL  GAS/GASOLINE PROCESSING PLANTS
                                                                                             420.00 MKCFD
 COMPANY  NAME/SITE  LOCATION   CHEVRON U.S.A.
                                                                                             UINTA, MY
 DETERMINATION  IS
 PERMIT NO. CT-297
 DETERMINATION  MADE BY
                            WYOMING AQD
                              (AGENCY)
                        LEE GRIBOVICZ
                     (AGENCY CONTACT PERSON)
                                    DATE OF  PERMIT ISSUANCE—   05/28/80
                                    ESTIMATED DATE OF START-UP—   1983
                                    (307J-332-3144
                                        (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
   THROUGHPUT        POLLUTANT    EMISSION LIMITS   '                                ...& BASIS
    CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ...  PCT EFF
SULFUR PLANT & TGU, 3 EA
REHEATER, STACK GAS, 3 EA
HEATER, GLYCOL STILL, 3 EA
HEATER, PROCESS, 3 EA
FURNACE, G4S, 3 EA
1000.00 T/D




  23.00 MMBTU/H


  10.00 MMBTU/H


  62.50 MMBTU/H


  10.00 MMBTU/H
CO      220.0000 LB/H
COS     460.0000 LB/H
H2S       8.2000 LB/H
                 3 STAGE CLAUS - BEAVQN

NOX       0.2000 LB/MMBTU
                 DESIGN

NOX       0.2000 LB/MM3TU
                 DESIGN

NOX       0.2000 LB/MMSTU
                 DESIGN

NOX       0.2000 LB/f^BTU
                 DESIGN
BACT
BACT
BACT
99.70

BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
PAGE G- 496

-------
 (CONTINUED) CHEVRON U.S.A.
                                       THROUGHPUT         POLLUTANT     EMISSION  LIMITS                                    .    t BASIS
                                        CAPACITY           EMITTED             CONTROL EQUIPMENT OR  PROCESS MODIFICATION  . . .  PCT EFF
 BOILER, GAS, 6 EA
                                      93.80 MMBTU/H
                                                           NOX
0.2000 LB/MMBTU
       DESIGN
                                                                                                                              BACT
 NOTES
                                                PROCESSINS TRAIN HITH * 1°°° T/D SULFUR RECOVERY CAPACITY. TGU REPRESENTS A TH
    INDICATES DATUM WAS TRUNCATED FOR  THIS TABLE.
                                INITIAL
                   REVIEW STATUS--
PAGE G"
                                                      ID
                                                               WY-0009

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                         05/23/1934
— = — = £ = " ~~ — ~ — cr = ~ — rrr r~ ~s rs = ~~~s:=~z~— ~~~~~rc— z~=~r = ^zc = ~ = ~ = = czc=~— =z — —=~=~— ~s~~~s~~~~~~~r = ~~~rrr:^z — =~~ ~^r^ = c = ~ = ~~~r:=^ = ~~ = s~s —^"~^ —z


SOURCE TYPE/SIZE	         NATURAL GAS/GASOLINE PROCESSING PLANTS                            60.00 MttCFD


COMPANY NAME/SITE LOCATION  CIG                                                                   , WY
                                                                                                                  SWEETWATER COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE OF  PERMIT ISSUANCE—  08/25/76
PERMIT NO. CT-58                                                                               ESTIMATED DATE OF  START-UP—   1977
DETERMINATION MADE BY       WYOMING AQD                    LEE GRIBOVICZ                       (307)-332-314
-------
                                            APPENDIX  — DETAILED  SOURCE  LISTING
                                                                                                                        05/22/19S4
SOURCE TYPE/SIZE—         NATURAL GAS/GASOLINE  PROCESSING  PLANTS                              3.09  KMCFD


COMPANY NAME/SITE LOCATION  CRYSTAL EXPLORATION CO.                      •              MARATHON TUP,  MI
                                                                                                                     LAPEER COUNTY


DETERMINATION IS BACT FOR A NEW SOURCE.                                                         DATE  OF PERMIT ISSUANCE—  11/30/82
PERMIT NO. 238-80E                                                                             ESTIMATED DATE OF START-UP—   1983
DETERMINATION MADE BY       MICHIGAN DNR                  GREGORY  EDWARDS                     (517)-322-1333
                             (AGENCY)                   (AGENCY CONTACT  PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT         POLLUTANT     EMISSION LIMITS                                   ...  * BASIS
TO THIS PERMIT                        CAPACITY           EMITTED             CONTROL EQUIPMENT OR  PROCESS MOOIFICATION  ...  PCT EFF
	..	--..	.	_	_--	_--,	

SWEETENING FACILITIES                 3.09 MMCF/D
                                                          H2S       96.0000  •/. REMOVAL FROM ACID GAS  STRM
                                                                            TWO  STAGE CAUSTIC SCRUBBER                       96.00
                                                          SOZ    1350.0000  LB/D
                                                                            SOUR GAS INCINERATOR                              99.50


NOTES 	
MICHIGAN REGULATIONS REQUIRE BACT FOR ALL NEW NATURAL GAS SWEETENING FACILITIES.
(*> INDICATES DATUM WAS TRUNCATED FOR  THIS  TABLE.

PAGE G- 499
                                                      ID  NUMBER  MI-0029
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS:  04/01/19S3    04/19/1984

                  SOURCE TYPE CODE   5.12

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                         05/22/1984



 SOURCE TYPE/SIZE—         NATURAL GAS/GASOLINE PROCESSING PLANTS                          1642.50 MMSCF/YR
                            	

 COMPANY NAME/SITE LOCATION  CRYSTAL OIL CO.                                                HOSSTON, LA
                                                                                                                      CADDO PARISH
                            __-,	— __	— — — — — — — — — — — — — - — — — — — — — — — — — — — — — —. — — — — — _ — — _ — __ — — «._-._„«._„_____„„._____,„___„„____,.__„	_	_	_____

 DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE—  10/19/83
 PERMIT NO. PSD-LA-510                                                                          ESTIMATED DATE OF START-UP-
 DETERMINATION MADE BY       LAQD/EPA REGION VI             NAN KILLEEN                         (504)-342-8940
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)




 PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... t BASIS
 TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF


 FLARE, 83-81                        300.00 BTU/SCF
                                                           S02     144.4800 LB/H


 NOTES 	
 NO APPLICABLE NSPS FOR GAS  PROCESSING PLANTS.  PERMIT INCLUDES PROVISION FOR RE-EVALUATION OF BACT> DEPENDING UPOM K2S CONTENT
 OF SCUR GAS STEAM.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 500
                                                      ID  NUMBER  LA-0046
 INITIAL REVIEW  POST STARTUP
5--

      SOURCE TYPE CODE   5.12

-------
                                             APPENDIX — DETAILED SOURCE LISTING
 ================= ======	                   __                                                       05/22/1984
                                                      =-=======-_=========== ====== = ===== === = ===____________________=__________ = ___


 SOURCE TYPE/SIZE—         NATURAL GAS/GASOLINE PROCESSING  PLANTS                           60.00 MMCFD


 COMPANY NAME/SITE  LOCATION  DELHI GAS PIPELINE CORP.                                        ATHENS, TX

                           	                                                         HENDERSON COUNTY


                                                                                              DATE OF PERMIT ISSUANCE—  04/29/82
 DETERMINATION MADE BY       TEXAS ACB                     STUART KEIL                         ?I™-JS-Sm * STA"T-UP"   1983
                             (AGENCY)                   (AGENCY CONTACT  PERSON)                    (PHONE)



                                      THROUGHPUT        POLLUTANT   EMISSION LIMITS                                   ..  & BASIS
 ___			_	"^ITY  _       EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF

 GAS PROCESSING PLANT - SULFUR        37.70  LT/D
                                                          SOS      92.9000 T/YR
                                                                  400.0000 PPM

 GAS PROCESSING PLANT - GAS           60.00  MMCF/D                           * ^"^ CUUS PLANT/SCOT TA1L GAS                99.70
                                                          H2S       1.3000 T/YR
                                                                   10.0000 PPM

NOTES 	
CONCENTRATIONS OF S02  AND H2S ARE CALCULATED ON A DRY, OXYGEN FREE BASIS AT INCINERATOR EXIT.














                                    -™".I*!H:			                    REVIEW
                                                     ID  NUMBER  TX-0096

-------
                                             APPENDIX  --  DETAILED  SOURCE  LISTING
                                                                                                                        05/32/1984
SOURCE TYPE/SIZE—
NATURAL GAS/GASOLINE PROCESSING PLANTS
                                                                                              11.50  MJ1CFD
COMPANY NAME/SITE LOCATION  ENDERCO
DETERMINATION IS BACT FOR A MODIFIED SOURCE.
PERMIT NO. PSD-704-A
DETERMINATION MADE BY       ARKANSAS DEP
                             (AGENCY)
                               CECIL HARRELL
                            (AGENCY  CONTACT  PERSON)
                                                                                           GARLAND,  AR
                                                                                                                     MILLER  COUNTY
                                       DATE OF PERMIT ISSUANCE—  02/23/83
                                       ESTIMATED DATE OF START-UP—   1933
                                       (50D-562-7444
                                           (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
          THROUGHPUT
           CAPACITY
POLLUTANT
 EMITTED
EMISSION LIMITS
       CONTROL EQUIPMENT OR PROCESS MODIFICATION
* BASIS
PCT EFF
AMINE SWEETENING CLAUS
                                     11.50  MMCF/D
                                                          S02
                                       155.0000  LB/H
                                                CLAUS PLANT
                                                                     BACT
                                                                     90.00
NOTES
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 502
                                                                                                     INITIAL REVIEW  POST STARTUP
                                                                                        REVIEW STATUS;
                          ID NUMBER AR-0011
                                                                              SOURCE TYPE  CODE    5.12

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/32/1984
 SOURCE TYPE/SIZE—          NATURAL GAS/GASOLINE PROCESSING PLANTS


 COMPANY NAME/SITE  LOCATION   ETEXAS PRODUCERS 6AS CO.
                                      15.00 HHCFD
                                                                                                    TX
                                                                                                                      SMITH COUNTY
 DETERMINATION  IS BACT  FOR A NEW SOURCE.
 PERMIT  NO. X-3832
 DETERMINATION  MADE BY       TEXAS ACS
                             (AGENCY)
NOTES
   JENNIFER SEINFELD
(AGENCY CONTACT PERSON)
DATE OF PERMIT ISSUANCE—  10/05/82
ESTIMATED DATE OF START-UP—   1933
(5ia)-451-5711
    (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
HOT OIL HEATER

REGENERATION HEATER

COMPRESSOR






THROUGHPUT POLLUTANT
CAPACITY EMITTED
2.26 MMBTU/H
NOX
1.31 MMBTU/H
NOX
700.00 HP
VOC

NOX

CO

EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

2.1000 T/YR
SHEET NAT GAS FIRED
1.4000 T/YR
SWEET NAT GAS FIRED
3.0000 T/YR
4.4000 G/HP-H
67.0000 T/YR
10.0000 G/KP-H
9.0000 T/YR
1.4COO G/KP-H
... 8 BASIS
... PCT EFF

AP42

AP42







                                                          VOC
                                                                    24.0000  T/YR
                                                                                                                             AP42
(*) INDICATES DATUM WAS TRUNCATED FOR  THIS TABLE.

PAGE G- 503
                                              INITIAL REVIEW   POST  STARTUP
                                REVIEW STATUS:   05/04/19S4
                                                     ID NUMBER TX-0123
                                                                                                          SOURCE TYPE CCDE   5.12

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE---
                            NATURAL GAS/GASOLINE PROCESSING PLANTS
                                                                                              24.00 MMCFD NAT GAS
COMPANY NAME/SITE LOCATION  EXXON CO., U.S.A.
                            6 MI. N. GILMER W. HWY 271
                                    GILMER, TX
                                                                                                                     UPSHAW COUNTY
DETERMINATION IS BACT FOR A NEW SOURCE. •
PERMIT NO. (REGION FILE NO.) PSD-TX-362
DETERMINATION MADE BY       EPA REGION VI
                             (AGENCY)
   JOHN BUNYAK
(AGENCY CONTACT PERSON)
DATE OF PERMIT ISSUANCE—  02/09/82
ESTIMATED DATE OP START-UP--
<214)-767-15
-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/23/198*
 SOURCE TYPE/SIZE—-         NATURAL  GAS/GASOLINE PROCESSING PLANTS


 COMPANY NAME/SITE  LOCATION  LIQUID ENERGY CORP.
        60.00 MMCFD


NEAR ARTESIA, NM
 DETERMINATION IS BACT FOR  A NEW SOURCE.
 PERMIT NO.  NM-389
 DETERMINATION MADE  BY       AIR QUALITY BUREAU - NMEIO     SHANKAR ANANTHAKRISHNA
                              (AGENCY)                   (AGENCY CONTACT PERSON)
         DATE OF PERMIT ISSUANCE—  12/10/81
         ESTIMATED DATE OF START-UP—   1981
         (5Q5)-9S4-0020
             (PHONE)
                                      THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    . . . & BASIS
 --_---______	         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   .. . PCT EFF
                                                                       •	•	.	

 ENGINE, I.C. COMPRESSOR            2000.00 HP
                                                           NOX       3.4000 G/HP-H

 ENGINE, I.C. COMPRESSOR            2000.00 HP                               L°W ^ EN5INE
                                                           NOX       3.4000 G/HP-H

 ENGINE, I.C. COMPRESSOR            2000.00 HP                               "* *"* ™G™
                                                           NOX       3.4000 G/HP-H
                                                                            LOW NOX ENGINE


 NOTES 	

                             2°' WERE PERFORMED ON ALL THREE ENSINES & THE ACTUAL EMISSIONS WERE 2.01 G/HP-H, 2.6 G/HP-H, & 3.












                                                ^		______REVIEW
PAGE G-  5C5                                           1D NUMQFR  KM-0003

-------
                                             APPENDIX  --  DETAILED  SOURCE  LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE —
                            NATURAL GAS/GASOLINE PROCESSING  PLANTS
COMPANY NAME/SITE LOCATION  MAPCO PRODUCTION CO.
                                                                                      NEAR  ROSWELL,  NM
DETERMINATION IS BACT FOR A MODIFIED SOURCE.
PERMIT NO. PSD-NM-576
DETERMINATION MADE BY       AIR QUALITY BUREAU -  NMEIO      SHANKAR  ANANTHAKRISHNA
                             (AGENCY)                   (AGENCY CONTACT  PERSON)
                                                           DATE  OF  PERMIT ISSUANCE—  01/14/83
                                                           ESTIMATED DATE OF  START-UP—    1983
                                                           (5051-934-0020
                                                               (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
  THROUGHPUT
   CAPACITY
POLLUTANT    EMISSION LIMITS                                   ...  t BASIS
 EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ...  PCT EFF
ACID CAS FLARE
ENGINE, I.C. COMPRESSOR
ENGINE, I.C. COMPRESSOR
ENGINE, I.C. COMPRESSOR
ENGINE, I.C. COMPRESSOR
                                      7.50 MMSCFD
446.00 HP
670.00 HP
507.00 HP
                                    278.00 HP
   S02     703.0000 LB/H
                    DIETHANOL AMINE UNIT

   NOX       9.0000 G/HP-H
                    AIR/FUEL RATIO

   NOX       9.0000 G/HP-H
                    AIR/FUEL RATIO

   NOX       9.0000 G/HP-H
                    AIR/FUEL RATIO
                                                          NOX
                                                                     9.0000 G/HP-H
                                                                           AIR/FUEL  RATIO
NOTES 	
STACK TESTS, EPA REF. METHOD 7, WERE PERFORMED  ON ALL FOUR  ENGINES  S  EMISSIONS  WERE  7.1  G/HP-H.
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.
                                                                                                     INITIAL REVIEW  POST STARTUP
                                                                                        REVIEW STATUS:  04/01/1933
PAGE G- 5C6
                                                     ID NUMBER NM-0007
                                                                                                          SOURCE TYPE CODE   5.12

-------
                                              APPENDIX — DETAILED SOURCE LISTINS

 r = = = — = = r = = = = = = = = = = ---____.„__._______.„_________	  ^               ^                    05/32/1934





 SOURCE TYPE/SIZE—         NATURAL GAS/GASOLINE PROCESSING PLANTS                             7.10 MMCFD




 COMPANY NAME/SITE LOCATION  MARATHON OIL CO.
                                                                                                   > WI

                            	 _                                                                                       PARK COUNTY



 DETERMINATION IS BACT FOR A NEW SOURCE
 PERMIT NO  CT-479               =>"UKLt.                                                         DATE Qf PERHIT ISSUANCE__  01/20/83


 DETERMINATION MADE BY       WYOMING AQD                     CHUCK COLLINS                 '      f™-™ ™[ ™ 5J^'UP"   19M

                              <*SENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)






                                       THROUGHPUT        POLLUTANT    EMISSION LIMITS                                       , BASIS

 -..	           CAPACITY           EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  \ '.'. PCT EF?



 STILL,  GLYCOL                         0.76  MMBTU/H


 HF4TFO  HOT nn                                             NOX        0.2000 LB/KMBTU                                         STP
 HEATER, HOT OIL                       14.20  MM3TU/H                                                                            SIP

 .,._....        CIIIBIIB  n, A.rr                                  NOX        0.2000 LB/MMBTU                                         SIp
 INCINERATOR,  SULFUR  PLANT             2.50  MMBTU/H

                                                            S02       79.8000 LB/H                                              BACT

                                                                     31.9000 LB/KMBTU

                                                                             5 LTD CLAUS                                       90.00



 NOTES 	
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.
PAGE G- 507
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS;
                                                      ID NUMBER WY-0002
                                                                                                           SOURCE TYPE CODE   5.12

-------
                                              APPENDIX — DETAILED  SOURCE LISTING
                                                                                                                         05/32/1984



SOURCE TYPE/SIZE—-         NATURAL GAS/GASOLINE  PROCESSING  PLANTS                            12.50 MMCFD
                            — — — — — — — — — — — — — — — — — — — — ———— — — — — — — — — —— — — w — —. — — — -. — —— — — M-. — — — — — — _» —w—_____». — ««,_.__.._w__. _ H ___ __ __ — _..___-._.. _•«._«._„

COMPANY NAME/SITE LOCATION  MOUNTAIN FUEL SUPPLY                                              UINTA, WY
                            — — — — —— — — — — — — —— — — — — — — —— — — — — — — — — —^ —j—^-. —— — — — — — — — — «-—. — — — «. — • — —^ — —— •_ — — —— i^ — — ». —_»_«_ —•,^»™»^«,^^«.__ — ^«._»._„.«_ —_^ —_„.__

DETERMINATION IS BACT FOR A NEW SOURCE.                                                         DATE OF PERMIT ISSUANCE—  08/01/78
PERMIT NO. CT-117                                                                               ESTIMATED DATE OF START-UP—   1
-------
                                              APPENDIX  — DETAILED  SOURCE  LISTING
                                                                                                                         05/22/1984
 SOURCE TYPE/SIZE	         NATURAL GAS/GASOLINE  PROCESSING PLANTS


 COMPANY NAME/SITE LOCATION  PACIFIC ALASKA  LNG ASSOCIATES
                                                                                             KENAI, AK
 DETERMINATION IS BACT FOR A NEW SOURCE.
 PERMIT NO. 8423-AA002
 DETERMINATION MADE BY       ALASKA DEC
                              (AGENCY)
                     DAVE ESTES
                  (AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE—  01/30/84
                                       ESTIMATED DATE OF START-UP--   1987
                                       (907)-465-2666
                                           (PHONE)
 PROCESSES SUBJECT
 TO THIS PERMIT
 HEATER,  PROCESS,  GAS  FIRED, 5
THROUGHPUT
 CAPACITY
POLLUTANT    EMISSION LIMITS
                                                         EMITTED
                                                           NOX
                                                               ... & BASIS
                                                                            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF
                                                                    38.0000 NG/J
                                                                     0.0900 LB/MKBTU
                                                                            LOW NOX BURNERS
                                                                                       BACT
NOTES
 THIS B4CT DETERMINATION RESULTED FROM AN IS MONTH REQUEST FOR EXTENSION AT A FACILITY PREVIOUSLY PERMITTED
                                                                                                           BY EPA REGION 10.
<*) INDICATES DATUM WAS TRUNCATED FOR  THIS  TABLE.

PAGE G- 509
                                                                                                      TWTTTAL  REVIEW  POST STARTUP
                                                                                                                              5.12

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE—         NATURAL GAS/GASOLINE PROCESSING PLANTS


COMPANY NAME/SITE LOCATION  PHILADELPHIA GAS WORKS                                    PHILADELPHIA,  PA
                                                                                                               PHILADELPHIA COUNTY


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE  OF PERMIT ISSUANCE—  05/15/79
PERMIT NO. 78PA03                                                                              ESTIMATED DATE OF START-UP—
DETERMINATION MADE BY       EPA REGION III                 VERNON BUTLER                       (3151-557-2711
                             (AGENCY 1                   (AGENCY CONTACT PERSON 1                     (PHCN'E 1



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   .. .  t, BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ...  PCT EFF


BOILER                              110.00 MBTU/H
                                                           PM         5.4000 LB/H                                             BACT
                                                           S02       75.0000 LB/H                                             BACT
                                                                            STRETFORD
                                                                            LOW  S FUEL
                                                           NOX       74.0000 LB/H                                             BACT
STORAGE TANKS                         1.00 MMBBL/YR
                                                           VOC       91.0000 T/YR                                             BACT
                                                                            DEL  SEALS, FLOAT.  ROOF TANKS


NOTES 	











                                                                                                      INITIAL REVIEW   POST  STARTUP
<*! INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEW STATUS:   04/C1/1933

PAGE G- 510                                           ID NUMBER PA-0002                                    SOURCE TYPE CODE   5.12

-------
                                             APPENDIX -- DETAILED SOURCE  LISTING
                                                                                                                         05/22/1984
 SOURCE  TYPE/SIZE—          NATURAL GAS/GASOLINE PROCESSING PLANTS


 COMPANY NAME/SITE  LOCATION   PHILLIPS PETROLEUM CO.
                                                                                              30.00 WSCFD
DETERMINATION MADE BY
T00THTf PFPH?TECT
 °™"
                                                                                                    NO
    SOURCE-
NORTH DAKOTA SHD
 (AGENCY)
                                                           GARY HELBINS
                                                        (AGENCY CONTACT PERSON)
                                                                                                    OF  PERMIT

                                                                                                     S!-
                                                                                                    (PHONE)
                                                                                                                   WILLIAMS COUNTY


                                                                                                                      —  10/25/82
          THROUGHPUT
           CAPACITY
                                                        POLLUTANT-    EMISSION LIMITS
                                                         EMITTED             CONTROL EQUIPMENT OR PROCESS MODIFICATION
                                                                                                                            & BASIS
                                                                                                                            FCT  EFF
INCINERATOR STACK
NOTES
                                     30.00 MMCF/D
                                                           S02      93.3000 LB/H
                                                                            CLAUS PLANT
                                                                                                                             BACT
                                                                                                                             98.50

                                                     ID f!Uf
                                                               ND-OOC2

-------
                                             APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                       05/22/198*
SOURCE TYPE/SIZE---         NATURAL GAS/GASOLINE  PROCESSING PLANTS


COMPANY NAME/SITE LOCATION  PHILLIPS PETROLEUM  CO.                                        MALJAMAR, KM
                            HWY 126 15 HI.  S. OF  MALJAMAR                                                                LEA COUNTY
                           	

DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE—  10/08/81
PERMIT HO. (REGION FILE NO.) PSD-HM-389                                                       ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY       EPA REGION VI                 JOHN BENHAM                         (214(-767-1594
                             (AGENCY)                   (AGENCY CONTACT  PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT         POLLUTANT     EMISSION  LIMITS                                    • • • & BASIS
TO THIS PERMIT                         CAPACITY         EMITTED             CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF
		

ENGINE, I.C. COMPRESSOR, 2 EA       585.00  HP EA
                                                          NOX       11.0000  G/HP-H
                                                                            AIR/FUEL  RATIO



NOTES 	
2 INTERNAL COMBUSTION COMPRESSOR ENGINES.
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 512
10 NUMBER NM-0003
                                                INITIAL REVIEW  POST STARTUP
                                   REVIEW STATUS:   04/01/1933

                                                     SOURCE TYPE CODE   5.12

-------
                                              APPENDIX  --  DETAILED  SOURCE LISTING
 --__--.......___	                                                                              05/22/1984



 SOURCE TYPE/SIZE—         NATURAL GAS/GASOLINE  PROCESSING  PLANTS
                            	

 COMPANY NAME/SITE  LOCATION  PHILLIPS PETROLEUM CO.                                     BARTLESVILLE, TX 74009
                             PHILLIPS BUILDING
                            ~     - ——         —-__-,   _,-_—   _______ ___—..__,*.__.._	—. — _ — __.„_«.__«	„	„_.,.______,.	-. — -.-.__.._,.... _-._ — __„

 DETERMINATION IS BACT FOR  A MODIFIED SOURCE.                                                    DATE OF PFDMTT ISSUANCE—  01/30/SO
 PERMIT NO.  (REGION FILE  NO.) FSD-TX-314                                                         ESTIMATED OAT? " START-UP--
 DETERMINATION MADE BY       EPA REGION VI                  JOE  WINKLER                         (214)-767-1594
                              (AGENCY)                  (AGENCY CONTACT PERSON)                    (PHONE)



 PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION LIMITS                                   . .  4 BASIS
 TO  THIS PERMIT                        CAPACITY           EMITTED             CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ... PCT EFF


 I.C. COMPRESSOR ENGINES              650.00 HP EA
                                                           NOX       12.4000  G/HP-H                                           BACT

 TURBINE  COMPRESSOR ENGINES         3000.00 HP EA
                                                           NOX        1.8000  G/HP-H                                           BACT
                                                                             NORMAL OPERATION


 NOTES  	
















 (*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEW STATUS:   04/01/1933

PAGE G- 513                                           I0 NUMBER TX-0045                                     SOURCE     '''''

-------
                                             APPENDIX — DETAILED SOURCE LISTING
SOURCE TYPE/SIZE—-         NATURAL GAS/GASOLINE PROCESSING PLANTS
                           	


COMPANY NAME/SITE LOCATION  PROCESS EQUIPMENT CORP.                                        MAYFIELO, MI       ^^ TRAVERSE COUNTY





PEP-MIT NO. 813-81                                                                              /ci-»i i->o 1111
DETERMINATION MADE BY       MICHIGAN DNR                   DAVID FERRIER                       (517)-3.2-1333
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)




PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... t BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT EFF
__-__---_^w,--------.-~---- — -- —------------------,_-------	..____....___-.._-_- — --------	«..--_--- — -- — - — — --- — - — --- — - — - — --------- — ------


SOUR GAS SWEETENER                   10.00 MMSCFD
                                                           S02      81.1000 LB/MMSCF
                                                                            CLAUS UNIT                                       85.00



NOTES	—



















                                                                                                       INITIAL REVIEW  POST STARTUP

 (*)  INDICATES DATUM WAS TRUNCATED FOR  THIS TABLE.        ___				?™!-s!I*™!i= = = «" = "~ = = =="="«« = =

 plGrG-lir"========== = = = r= = = = === = = Z= = " = = " = = = = "="="lo"NUMBER"MI-OOC7                        •           SOIPCE  TYPE CODE   5.12

-------
                                              APPENDIX — DETAILED SOURCE  LISTING
 = = = = = = m = = = = r=- =	                                                                          05/22/198*


 SOURCE TYPE/SIZE—         NATURAL GAS/GASOLINE PROCESSING PLANTS                             39.00 MM8TU/H
                            ™"~'~'""""~~**~"*~"~'1I"~~~'"""*~""""~™"~*~ — ~"*~~*'~"'"'^ — -" — — — •* — •• — — — — — » — — ^^ — — —— — — ^ — — — -^ — — — — — » — — _^_ _ _ _

 COMPANY NAME/SITE LOCATION  REPUBLIC REFINING CO.                                             JOHNS, MS
                                                                                                                       RANKIN COUNTY
                                            "  "            ——— — — _W— __	,.	.»_..___	— — — —_*,__„«,_	_ __	,	.___	—	— _«.


 PERMIT NO. (REGION F!LE NO.) PSD-MS-037                                                         ESSIES ofsTA^'uP °8/C3/81
 DETERMINATION MADE BY       MISSISSIPPI DNR                DWIGHT WILEY                         "JlTJS-2550    START-UP"
                              (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



                                       THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                    ... 4 BASIS
                                        CAPACITY          EMITTED            CONTROL  EQUIPMENT OP PROCESS MODIFICATION   ... PCT EFF


 NAT.  GAS PROCESSING-SULFUR RECO*     50.00  MMCF/D
                                                            S02       0.0030 LB/H EA                                           BACT
                                                                             TREATED  NAT.  GAS FOR BOILERS

 NOTES 	
 TWO BOILERS

















<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEW  STATUS^il/Ol/lSr  ^^ STARTUP
= = = = = " = = = = = = = r = = = = —= - = = = = = = — — — — — — - — ----_-_-___. = = = = = = = = = r = r = = r = = === = = -::=r = = r = = r = rr = r = = = = z = = r = = = rr = = :r::r = = = = = = = = = = === = = = = =
PAGE G- 515                                            ID NUISER  MS-OOO*                                      SOL'PCE  TYPE  CCOE   5.12

-------
                                              APPENDIX — DETAILED SOURCE  LISTING
SOURCE TYPE/SIZE—-          NATURAL GAS/GASOLINE PROCESSING PLANTS



COMPANY NAME/SITE LOCATION   SHELL OIL CO.                                          FREDERIC TOWNSHIP, MI              rD,UCnr>n rraiviTY
                             SECTION 10                         .                                                      CRAWFORD COUN1T






DETERMINATION MADE BY        MICHIGAN DNR                   LAURA STEINBERGER                    (517)-322-1333
                              (AGENCY)                   (AGENCY CONTACT  PERSON)                     (PHONE)





PROCESSES SUBJECT                      THROUGHPUT        POLLUTANT     EMISSION LIMITS                                    • • • * BASIS
TO THIS PERMIT                          CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
                                                                                          — ___„,«.••„..._.,—. — •• — — •• — — — — • — — -• — ~ — — — — — — — *- — — — — "*
 • — •„_»_ — — •».» — »•»»»•. —™» — •••• — •« — — •- — •••• — — •- — — — — -•"•• — -" — "• — "•"' — — — — ™— — "* — ""**~*~'™~""'~*~~'~™"'~™' — """""<~""~~"~""~""~™'~°~'~"


GAS SWEETENING  FACILITY                7.00 MMCF/D
                                                            S02
                                                                             3-STAGE CLAUS UNIT                                93.50

                                                            S02      184.0000 LB/H
                                                                     540.0000 LB/H
                                                                             GROUND LEVEL INCINERATOR                          99.90




NOTES 	
2NO ALTERNATE  LIMIT -  2100  LB/0


















                                                                                                         INITIAL  REVIEW  POST STARTUP

(*) INDICATES  DATUM WAS TRUNCATED  FOR THIS TABLE.                                  	?^!".!I*I"!i__?^.!^-!!!	.	_--.-

= ™™™ = "" = = = = "=S"" = = " = = :: = = "S              io"NUMBER"MI-0031                                     SOL'PCE TYPE CODE   5.12

-------
                                              APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                          05/22/1984
 SOURCE TYPE/SIZE—         NATURAL GAS/GASOLINE PROCESSING PLANTS                            U7.00 HMSCFD

 COMPANY NAME/SITE LOCATION  SIO RICHARDSON CARBON fc GASOLINE CO.                             KERMIT, TX
                                                                                                                      WINKLER COUNTY
 DETERMINATION IS BACT FOR A MODIFIED sntlPrp
 PERMIT NO  272"            nooiFIED SOURCE.                                                    OATE OF PERMIT iSSUANCE—  01/14/31
 DETERMINATION MADF BY       TFVAC Arn                                                           ESTIMATED DATE OF START-UP—   1981
 utit.,ruNAIJOH MADE BY       TEXAS ACS                      LES MONTGOMERY                       (51Z )-451-5711
                              (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)
                                       THROUGHPUT        POLLUTANT    EMISSION LIMITS                                        s e4SIS
                        _____           CAPACITY          EMITTED            CONTROL EQUIPMENT  OR  PROCESS MODIFICATION  . . . PCT EFF
                                                     ~'~^~'~""~""'*"" — *"~*™"~"~**"* — *"""""™*™ — '~"*™"™""""""""™"~~"""""~~""~*-~ — "•-••- — — •• — *-•- — —•«— — — — •• — ~-> — — ..^ — — _™ •_„_„
 NATURAL  GAS TREATING PLANT          117.00 MMSCFD
                                                            S02     816.0000 T/YR
                                                                             SELECTOX S RECOV.  UNIT                            95.00
NOTES
                                    v™ «* NTSULFIDE EXTRACTED FROM RAW NATURAL GAS TO ELEMENTAL SULFUR.  THIS UNIT IS A THREE
 „« TC  A  M*.                      /- CONVERSION TO H2S.  THE REMAINDER IS INCINERATED TO S02.
THIS IS  A SMALL UNIT  IN AN ISOLATED LOCATION.
1!---^^.IP.DATUM WAS TRUNCATE0 FOR THIS TABLE.                                         REVIEW STATUS:  04/01/1933"   ^^

PAGE G" 51?                                           1° "UMBER TX-0094                                     SOUSCE~TYPrcODT=Tl2

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE-—         NATURAL GAS/GASOLINE PROCESSING PLANTS                            10.00 MMCFD


COMPANY NAME/SITE LOCATION  WARREN PETROLEUM CO.                                              VADA, MM 88267
                            20 MI. NH OF TATUM                                                                          LEA COUNTY


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE—  12/23/81
PERMIT NO. (REGION FILE NO.) PSO-NM-156M-1                                                     ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY       EPA REGION VI                  TOM DIGGS                           (214 )-767-159<+
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ...& BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ... PCT EFF


ACID GAS FLARE                       10.00 MMSCFD
                                                           S02     703.0000 LB/H
                                                                     0.0016 LB/SCF
                                                                            DIETHANOL AMINE UNIT


NOTES 	
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 518
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                          -.-iCri STAIUS:   0-4, Cl/1933
ID NUMBER NM-0005
                                                     SOURCE TYPE CODE   5.12

-------
                                             APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                         05/22/1984
SOURCE TYPE/SIZE—         NATURAL GAS/GASOLINE  PROCESSING  PLANTS
                           «- — — — — •- — — — — — — — — ™, — _ » _ _ „__ • _ ___ — — — •• — .. — _,.__,.


COMPANY NAME/SITE LOCATION  WARREN PETROLEUM CO.
                                                                                               24.00 MMCFD
                                                                                                                   BILLINGS COUNTY
 DETERMINATION IS BACT  FOR  A  MODIFIED SOURCE
 PERMIT  NO.
 DETERMINATION MADE  BY        NORTH DAKOTA SHD
                              (AGENCY)
                                                          TERRY O'CLAIR
                                                       (AGENCY CONTACT PERSON)
DATE OF PERMIT ISSUANCE—  01/12/83
ESTIMATED DATE OF START-UP--
(70D-224-2348
    (PHONE)
 PROCESSES SUBJECT
 TO THIS  PERMIT
                                     THROUGHPUT        POLLUTANT    EMISSION  LIMITS
                                      CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS  MODIFICATION
                            & BASIS
                            PCT EFF
 INCINERATOR STACK
NOTES

               «
              30 nnCF/D .
                                                           S02
                                                                   534.0000 LB/H
                                                                            CLAUS & CBA
                                                                                                                             BACT
                                                                                                                             93.60
                              F/N EXISTING SOURCE' ™E EXISTING SOURCE CURRENTLY PROCESSES 20 - 24 KMCF/0 OF GAS WITH AN EMIS
                               AFTER EXPANSION THE ^W S02 EMISSION RATE WILL BE 534 LB/H « CAN HAWLE
(») INDICATES DATUM WAS TRUNCATED FOR THIS  TABLE.

PAGE G- 519
                                                                                                     INITIAL REVIEW  POST STARTUP
                                                                                        REVIEW STATUS:  04/01/1983
                                                      ID  NUMBER  ND-0001
                                                                                                           SOURCE TYPE CODE   5.12

-------
                                             APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                         05/32/1984
 SOURCE  TYPE/SIZE---
                             ASPHALT  *  ASSOCIATED PRODUCTS MFG./PROCESSING
 COMPANY NAME/SITE  LOCATION  KERNRIDGE OIL CO.
                             BELRIQGE OIL FIELD
                                                              CA
                                                                                                                       KERN COUNTY
DETERMINATION  IS BACT  FOR  A MODIFIED SOURCE.
PERMIT NO.  (REGION  FILE NO.)  SJ-79-26
DETERMINATION  tUOE  BY       EPA REGION IX
                              (AGENCY)
                     DON HARVEY
                  (AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE--  04/14/81
                                       ESTIMATED DATE OF START-UP--
                                       <415)-974-e223
                                           (FHCME)
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT    EMISSION LIMITS                                   ... & BASIS
 EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
STEAM GEN., 11 EA
                                     50.00 MKBTU/H
OIL WELL VENTS - EXISTING
OIL U'ELL VENTS - NEW
                     S02        0.0650 LB/MM3TU
                               1.2000 '/. S FUEL OIL
                                      S02 SC^L'SSER W/ EQUCTOR/VENTURI
                     NOX        0.2000 LB/M?!3TU
                                      LC'rl NOX BURNERS EXCESS 02 CONTROLLERS
                     PM         0.0570 LB/M!-:3TU
                                      S02 SCRUBBER W/ EDUCTCR/VENTURI
                     PM         o.oioo LB/n-t-jTU
                                      SCRUE3ER U/ ESP SECTION

                     VOC               NCNE
                                      VAPOR  RECOVERY

                     VOC               NOME
                                      SHUT IN WELLS
                                                                                                                             95.00
                                                                                                                             BACT
                                                                                                                             50.00
                                                                                                                             LAER
                                                                                                                             50.00
                                                                                                                             LAER
                                                                                                                             90.00
                                                                                                                             85.00
                                                                                                                            100.00
NOTES 	
PM EMISSIONS FROM ONE OF THE UNITS WILL BE CONTROLLED WITH AN ESP WHICH IS AN INNOVATIVE TECHNOLOGY AS APPLIED TO THERMALLY EN
HANGED OIL RECOVERY (TEOR ) .
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE 6- 520
                                                               INITIAL REVIEW   POST STARTUP
                                                  REVIEW STATUS:   04/ClA933     04/04/1954
                                                      ID  NU",3ER  CA-OC09
                                                                                                           SOURCE T\PE CCDE   5.13

-------
                                             APPENDIX — DETAILED SOURCE LISTING
 SOURCE  TYPE/SIZE—         ASPHALT & ASSOCIATED PRODUCTS MFG./PROCESSING


 COMPANY NAME/SITE  LOCATION  R.A. CHIIDS
                                                       130.00 T/YR
                                                                                                  ,  UT
DETERMINATION  IS BACT FOR A NEW SOURCE.
PERMIT NO. MIN 083182-5T
DETERMINATION  MADE BY       UTAH BAQ
                             (AGENCY)
                     DON ROBINSON
                  (AGENCY CONTACT PERSON)
DATE OF PERMIT ISSUANCE—  10/08/82
ESTIMATED DATE OF START-UP—   1983
(80D-533-6108
    (FKCME)
PROCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ...  $ BASIS
 CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ...  PCT EFF
DRUM DRYER
                                    130.00 T/H
                                                           PM        0.0200 GR/DSCF
                                                                     1.4900 LB/H
                                                                            VENTURI SCRUBBER
                                                           VE       20.0000 •/. OPACITY
                                                                                       99.00
NOTES 	
MOBILE ASPHALT PLANT
<*) INDICATES DATUM WAS TRUNCATED  FOR  THIS TABLE.

PAGE G- 5ZI
                                                                INITIAL  REVIEW   POST  STARTUP
                                                  REVIEW  STATUS:   C4/01/1033     02/13/1934
                                                     ID NUMBER UT-C030
                                                                                                           SCU^CE  TYPE  CODE    5.13

-------
                                             APPENDIX -- DETAILED SOURCE  LISTING
                                                                                                                         05/22/1984
r = r = r:r = : = : = = r = rr = = = = = = = :r = = = r = = :r = - = = = = = = = = = : = ::r; = = = = = = r = = = = = = = = r = = = = = = = rr = = = z= = = = = = r = = = = = = = r = r = = : = = rrrz = = r= = = = = r = r = r = rrr = = = = = = =


SOURCE TYPE/SIZE-—         ASPHALT 4 ASSOCIATED PRODUCTS MFG./PROCESSING                   30000.00 GAL


COMPANY NAME/SITE LOCATION  US OIL & REFINING CO.                                            TACOMA, HA 98401
                            3001 MARSHALL AVE.
                           — —	- — —	-.-. — — — — _ — — _ — _».	-,___-__-.__..	_	—	__ — — __ — .»_ —		

DETERMINATION IS BACT FOR A NEW SOURCE.                                                         DATE OF PERMIT ISSUANCE—  08/15/83
PERMIT NO. N/C 2455                                                                             ESTIMATED DATE OF START-UP—   1984
DETEPMINATION MADE BY       FL'GET SOUKT) APCA               HARRY WATTERS                        (205 1-344-7334
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHCNE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ...  4 BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT CR  PROCESS MODIFICATION  ...  PCT EFF
	--_-___-	-_„__--.-_-_-_.---	_-„	,	.	_	_„.„ — ___	«._—-_---_--_^	-_---_-_.	-. — _____-_-	„	--«_	_.---»_---_-__„_„„-

ASPHALT BLOW STILLS, 2            15000.00 GAL EA
                                                           P«        0.0200 LB/T ASPHALT  CHARGED
                                                                            INCINERATOR                                       95.00
                                                           S02       0.1000 CR/DSCF H2S IN FUEL GAS
                                                                            CONTIKO'JS r.CHITCRItiG


NOTES 	
APPROVED NOTICE OF CONSTRUCTION AND TRANSMITTAL LETTER DATED 08/15/83.  ASPHALT TRUCK LOADING  RACK  WITH HEAP  CONTROL,  AND  5  ASP
HALT STORAGE TANKS WITH HIGH ENERGY AIR FILTER,  HEAF,  CONTROL.
SOLACE CLAIMS CCNFIDENTIALITY FCR DETAILS OF PROCESS.
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 522
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS-.  04/13/1934
                                                      ID NUMBER WA-0009
                                                                                                           SC'Jf7CE TYPE CODE   5.13

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1934
 SOURCE TYPE/SIZE — -
                            CRUDE OIL/NAT. SAS PRODUCTION (INCL.  OIL SHALE)
COMPANY NAME/SITE LOCATION  AMINOIL USA, INC.
                                                                                  HUNTINGTON BEACH,  CA 92648
DETERMINATION IS BACT FOR A MODIFIED SOURCE.
PERMIT NO. NS9-4-4-9 LA-82-01
DETERMINATION MADE BY       EPA REGION IX
                             (AGENCY)
                     DAVID SOLOMON
                  (AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE—  08/04/82
                                       ESTIMATED DATE OF START-UP—
                                       (415J-974-8240
                                           (PHONE)
FPOCESSES SUBJECT
TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT    EMISSION LIMITS                                   ... 4 BASIS
 EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
TURBINE 4 WASTE HEAT BOILER
                                   6464.00 KW
                                                           SOX       14.0000  LB/H
                                                                            FGD  SYSTEM
                                                           BE         0.0000  LB/H
                                                                            UET  SCRUBBER  &  FGD  SYSTEM
                                                                                       BACT
                                                                                       95.00

                                                                                       99.00
NOTES 	
36.0 BBLS/H OF 1.34X SULFUR CRUDE OIL
(*) INDICATES DATUM WAS TRUNCATED FOR  THIS TABLE.

PAGE G- 523
                                                                INITIAL REVIEH   POST  STARTUP
                                                  REVIEW STATUS;   04/01/1933     04/04/1934
                                                      ID NUMBER CA-0035
                                                                                                           SOURCE  TYPE CODE    5.14

-------
                                             APPENDIX —  DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE-—         CRUDE OIL/NAT.  GAS PRODUCTION (INCL.  OIL SHALE)


COMPANY NAME/SITE LOCATION  BEREY HOLDING CO.                                                     .  CA
                            MIDWAY-SUNSET OIL FIELD                                                                     KEP.N COUNTY
                           _ ___ — __ — -__ — __ — _.__ — — — — — —-__. — — — — — -.__ _-.__ «__ __ — _ _ — _ — _ _ _ — ~ — _.._._ — __ — — • — —• — — — — — — — •• — —. — -. —- — — •. — — •. — — •— — ™— — — — — — — — — ——

DETERMINATION IS      FOR A MODIFIED SOURCE.                                                   DATE  OF PERMIT ISSUANCE--  02/23/61
PERMIT NO. (REGION FILE NO.) SJ-79-17                                                          ESTIMATED DATE OF START-UP—
DETERMINATION MADE BY       EPA REGION IX                  DON HARVEY                          (415)-974-82C3
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   . . . !, BASIS
TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... FCT EFF


COMPRESSOR, ROTARY SCREW,2 EA       500.00 HP
                                                           VOC     690.0000 PPM (AS CARBON)
                                                                            INCINERATION IN STEAM GENERATOR AT 2600 f        95.00
COMPRESSORS, RECIP. BOOSTER, 2 *
                                                           VOC      10.5000 LB/H 3X 02


NOTES 	
















                                                                                                      INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:  04/01/1933    0^/04/196'*

PAGE G- 524                                           ID  NUMBER CA-OOOS                                    SCU^CE TYPE CODE   5.14

-------
                                             APPENDIX -- DETAILED SOURCE LISTING
                                                                                                                         05/22/1984



SOURCE TYPE/SIZE—         CRUDE OIL/NAT. GAS PRODUCTION (INCL. OIL SHALE)                  450.00 KMBTU/H
                           — ~"**~~~'*~"-"~'"1™ — —— — — —— — — —————. — — — — — — _ __ _ ___ •_«,_ _«. ..._—.__.•_••. — — __ _. _ — • — — — _•.___._.._ ___«. _•____ •„__•_____ ___ _ — ^— _ —

COHPANr NAME/SITE LOCATION  CHEVRON USA, INC.                                          BAKERSFIELD, CA
                            P.O. BOX 5355


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF  PERMIT ISSUANCE-   07/16/82
PERMiT NO. NSR-4-4-8 SJ-79-33                                                                  ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY       EPA REGION IX                  BOB BAKER                           (415)-974-S215
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHCNE)

r = = = = = = r-r = = = - = = = r = = = r = = = = = = = r = r: = = r = = = = = r = = = = = = = = = = = = = = = = = = = = = = = = - = = = = = = = = = - = --- = - = ----_-_ = _ = _-___.___ = _...._.._______._____.__._

PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... 4 BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ... PCT  EFF
—— _    *_ —— . ___ •.___^_.w._p	^_	«	_	_	_,__	— — __ — _-.____to«. —_„,___„.„w_ —	— —_^.__	„	— — _ — _•_•«,	*.	«. _	._«,_._»_«•	»__..___

BOILERS, 9                          390.00 GAL/H, EA
                                                           SOS      18.8000 LB/H                                             BACT
                                                                            KET SCRUBBERS                                    90.00
                                                                            1.5X S LIMIT ON FUEL OIL
                                                           PM        3.6000 LB/H                                             LAER
                                                                            WET SCRUBBERS                                    50.00


NOTES 	















                                                                                                      INITIAL REVIEW  POST STARTUP
m^iraiCATES DATUM MAS TRUNCATED FOR THIS TABLE.                                         REVIEW STATUS:  04/01/1933    04/04/1984

PAGE G- 525                                           10  NUMBER CA-0037                                    SOURCE TYPE CCOE   5.14

-------
                                            APPENDIX — DETAILED SOURCE LISTING                                        05/22/1984




SOURCE TYPE/SIZE—         CRUDE OIL/NAT.  GAS  PRODUCTION (IK'CL. OIL SHALE)        ^   ^      24.00 MHCF         		


COMPANY NAME/SITE LOCATION  EXXON CO                                                  NEW ORLEANS, MS                      rniiNTY
                            P. 0. BOX 60626                                                                          HIHDS



                      fM A

                   sr                                   .^ocr «BSo«,



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                   ... * BASIS
Si"? PERMIT                         CAPACITY         EMITTED             CONTROL EQUIPMENT OR PPQCESS MODIFICATION  ... PCT EFF
                   		

TEST WELL                            25.00 MMCF/D
                                                           S02      745.0000  T/D  30 D  MAX
                                                                            FLARE                                            99.00



NOTES 	
TEST FACILITY — EXPECTED LIFE 120 DAYS.
 <*)  INDICATES  DATUM  WAS TRUNCATED FOR THIS TABLE.


 PAGE 6-  526
                                                                                                      INITIAL REVIEW  POST STARTUP
                                                                                         REVIEU STATUS:   04/01/1933
ID NUMBER MS-0001
                                                     SC'J7CE  TYPE  CCOE    5.14

-------
                                              APPENDIX — DETAILED SOURCE LISTING
 SOURCE TYPE/SIZE—         CRUDE OIL/NAT. GAS PRODUCTION  (INCL.  OIL SHALE)                   426.00 BBL/D


 COMPANY NAME/SITE LOCATION  GEOKINETICS INC., OIL SHALE                          40 MILES S.  VERNAL, UT
                                                                                                                        UINTAH  COUNTY
                            — — — — — — — — -- — --- — — -- — -- — -- — — — — — — — — — — — — — — —.-._..-...-..._..____.._.._ __ __._ ___ — — _-__ __ -. — _ — _ — ....__.«._«,_.„..________.„_ __ _.__

                                                                                                  DATE OF PERf1IT ISSUANCE--  11/13/80
        NO.                                                                                        ESTIMATED DATE OF START-UP--
 DETERMINATION MADE BY       EPA REGION VIII                JOHN  DALE                            ( 303 )-837-3763
                              (AGENCY)                   (AGENCY  CONTACT PERSON)                     (PHONE)

 = = = = = = r = = = = = = = = = = = z = = = = = = == = = = = : = : = = - = = -__---_.._. r = = = = = = = = = = = = = = - = = = = = r = - = = = = = = = = = = = = = = = = = = === = = = = = = = = __-.:__--__.. __„___-____„___

 PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                     ... J BASIS
 TO THIS PERMIT                         CAPACITY          EMITTED             CONTROL EQUIPMENT OR  PROCESS MODIFICATION   . . ". PCT EFF
 — ------------ — - -- -. — — — * — — _-,___»__.. --- _ __ ___ - — — — „ — »_^__, __ _«
                                                     ™—     — — — *••" — '•""•*• — — — *-^ — — — — •— — •— — — •• — — -- — » — — — — — — — — — •» — — — — — -. — -. — — — — — •. — ^ — ^•^•™_™^»,__,_ — «..__

 GENERATOR                            650.00 HP
                                                            NOX       38.9000 LB/H                                              BACT
                                                                              DESIGN
                                                            VE        20.0UOO '/. OPACITY
 INCINERATOR                          100.00 BBL/D
                                                            NOX       45.1000 LB/H                                              BACT
                                                                              NONE                                               0.00
                                                            S02      135.3000 LB/H                                              BACT
                                                                              NONE                                               0.00
                                                            VE        20.0000 Y. OPACITY


NOTES  — ........
 3.5 YR  OPERATION,  LIMITED  EXPERIMENTAL VARIANCE.









                                                                                                         •rv.Tt-T'i  nr.-Tr;j  PQ3J STARTUP
(*>  INDICATES DATUM  WAS  TRUNCATED  FOR  THIS  TABLE.                                          KL,i = ^ S FAILS:   0-4/01/1983

PAGE  G- 527                                            ID  KUMEcR L'T  C-,;,                                      . _•_  , .  7 , re CC2E   5.14

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/l«S4
SOURCE TYPE/SIZE	
                            CRUDE OIL/NAT. GAS PRODUCTION (INCL.  OIL SHALE)
                                                                                             225.00 MMSCFD
COMPANY NAME/SITE LOCATION  MOBIL OIL EXPLORATION
                                                                                                    AL
                                                                                                                     MOBILE COUNTY
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT NO. AL-07S
DETERMINATION HOE BY       ALAB4.MA APCD
                             (AGENCY)
   SUE ROBERTSON
(AGENCY CONTACT PERSON)
DATE OF PERMIT ISSUANCE--  10/16/81
ESTIMATED DATE OF START-UP--
(205) -334-6570
    (PHONE)
= = : = = : = r: = r: = = :r = = r = = = = r = = r = rr = rzrrr = = = r: = = -:rr = = == = = = r = = = z: = = = = :r = r = = = r = = r = = = = =rr: = = = = = = r = = = r: = = :r = = r = r = = rr: = r: = r = = = = = :
PROCESSES SUBJECT THROUGHPUT POLLUTANT EMISSION LIMITS
TO THIS PERMIT CAPACITY EMITTED CONTROL EQUIPMENT OR PROCESS MODIFICATION
NAT. GAS SULFUR REMOVAL 225.00 MMSCFD
S02

DIESEL ENGINES, 4 RIGS 1100.00 HP/ENGINE
CO

S02

NOX

PM

SUPPLEMENTAL BOILER 50.00 MM3TU/H
NOX

S02

SULFUR DEPOT BOILER 5.00 MKBTU/H
NOX

S02

200


9

7

71

3


0

1


0

z

.0000


.4000

.3000

.6000

.4000


.2000

.0000


.2000

.2000

LB/H EA
CLAUS AN'D SCOT TAIL GAS REMOVAL

LB/H-RIG
NONE
LB/H-RIG
LOU S FUEL
LB/H-RIG
NOME
LB/H-RIG
KCN'E

LB/rMSTU
STAGED COMBUSTION £ LOW EXCESS AIR
LB/H
LCW S FUEL

LB/KMSTU
STAGED COMBUSTION * LOW EXCESS AIR
LB/H
... t BASIS
.. . FCT EFF

BACT
Q9.86











54.00




37.00

                                                                            LOU S FUEL
PAGE G- 528

-------
 (CONTINUED) MOBIL OIL  EXPLORATION
 PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ...  4 BASIS
 TO  THIS  PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ...  PCT EFF
                            "                                                                  .».._....__	»,	

 TURBINE  GENERATOR, SAS-FIRED          7.50 KW
                                                           NOX     175.0000 PPM BY VOL
                                                                            NONE
                                                           SOZ       1.0000 LB/H
                                                                            LOW S FUEL
 PLATFORM GENERATORS, 5 EA., GAS*    661.00 HP/ENGINE
                                                           NOX     146.0000 LB/H-PLATFORM
                                                                            NONE
                                                           CO      146.0000 LB/H-PLATFORM
                                                                            NONE
                                                           SOZ       1.0000 LB/H-PLATFORM
                                                                            LCa S FUEL
NOTES 	
DRILLING PERMIT
                                                                                                      INITIAL REVIEW  POST STARTUP
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                         REVIEW STATUS:  04/01A9S3
PAGE G- 529                                           jD NUMBER AL-0010
                                                                                                           SCl'SCE TYPE CODE   5.14

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE	         CRUDE OIL/NAT. GAS PRODUCTION (INCL. OIL SHALE)                    1.00 MBBL/D


COMPANY NAME/SITE LOCATION  OXY-LOGAN WASH MODIF.1930                                NEAR DE BEQUE, CO
                                                                                                                   GARFIELD COUNTY


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE—  06/27/80
PERMIT NO.                                                                                     ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY       EPA REGION VIII                JOHN DALE                           <3031-S37-3763
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... t BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ... PCT EFF
BOILER, ETC
RETORT
                                   1000.00 BBL/D
CO        2.0000 LB/H
VOC       3.0000 LB/H
                 CCN'DENSCR
NOX      52.0000 LB/H
                 COiflJENSCR
PM        7.0000 LB/H
                 DUST CONTROL
S02      31.0000 LB/H

CO     3640.0000 LB/H
VOC     154.0000 LB/H
                 CC',DENSCR
H2S     376.0000 LB/H
                                                                                                                             BACT
                                                                                                                             BACT

                                                                                                                             BACT
                                                                                                                             60.00
                                                                                                                             BACT
                                                                                                                             50.00
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             60.00
                                                                                                                             BACT
NOTES 	
OPERATION OVER IN 1952
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 530
                                                      ID  NUMBER  CO-0009
                                           INITIAL REVIEW  POST STARTUP
                              REVIEW STATUS;  04/01/1933

                                                SC'JSCE TYPE CCDE   5.14

-------
                                             APPENDIX  — DETAILED  SOURCE  LISTING
 =	                                                                                            05/22/1984
                                ===s="===============-=====s=s===s-=---==s-s=s--===-==.=--ss=s=_==s=ss=s===__s____________________


 SOURCE TYPE/SIZE—         CRUDE  OIL/NAT. GAS PRODUCTION  (INCL. OIL  SHALE)
                            — ""' — — — "•— —— —-- —	—	_	„	——____	— _,-__..	_ _ _	— _-._•,.	__,-.	_	__ _ _ __..	— _„____.»_»,__	«._.	„	„_

 COMPANY NAME/SITE LOCATION  PARAHO DEVELOPMENT CORP.                                               f m

                                                                                                                      UINTAH COUNTY


                                                                                                     OF PERM" ISSUANCE-  11/16/82
 nFTFPMTMATTrw M«ne cv       ,,T.U D1o                                                            ESTIMATED DATE OF START-UP--   1990
 DETERMINATION MADE BY       UTAH BAO                       DONALD ROBINSON                      (801 )-533-6103
                              (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



                                      THROUGHPUT        POLLUTANT     EMISSION  LIMITS                                    ...  t BASIS
                                       CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ...  FCT EFF
BOLTING, SCALING, HANDLING, DRI*  75000.00 T/D SHALE
BLASTING
CRUSHING
IN MINE TRANSFER
MINE MOBILE EQUIPMENT
                                  54000.00 LB ANFO/D
                                  75000.00 T/D
                                  75000.00 T/D
                                  11730.00 6AL/D DIESE*
                                                           FUG*
                                                           CO
                                                           NOX
                                                           FUG*
PM


PM


PM

NOX

S02
voc
                                                                            WATER SPRAYING
         SETTLING

  0.0150 GR/DSCF
         BAGHOUSE

  0.0150 G3/DSCF
         BAGKCUSE

 11.0000 LB/MGAL
         SETTLING
3S5.2000 L8/MGAL
         CATALYTIC CONVERTER
 31.2000 LB/M3AL
  2.6000 LB/I-'GAL
         CATALYTIC COMV.
50.00




50.00


99.90


99.00


50.00

10.00


90.00
PAGE G- 531

-------
                                                           CO        4.5000 LB/MGAL
                                                                            CATALYTIC CONV.                                   95.00
PAGE G- SZZ

-------
(CONTINUED)  PARAHO DEVELOPMENT C03P.
PROCESSES SUBJECT
TO THIS PERMIT
MATERIAL HANDLING






STORAGE PILES


HYDROGEN PLANT REFORMER FURNACE













HYDROTREATER FEED FURNACE






POWER GENERATION FACILITY




THROUGHPUT POLLUTANT
CAPACITY EMITTED
75000.00 T/D
PM

PM

PM

VARIOUS SIZ*
PM

800.00 MMBTU/H
PM
CO
voc
NOX

S02
PM
CO
VOC
NOX

S02

41.25 MMBTU/H
PM
CO
VOC
NOX

SO 2
2110.00 MMBTU/H
FM
CO
VOC
NOX
EMISSION LIMITS
CONTROL EQUIPMENT Of! PROCESS MODIFICATION

0.0100 GR/DSCF
BAGHOUSE
0.0150 GR/DSCF
BAGHOUSE
0.0200 GR/DSCF
WET SCRUBBERS


WATER SPRAYS

15.0000 LB/MMCF
17.0000 LB/MMCF
3.0000 LB/MMCF
161.0000 LB/MMCF
LOU! NOX BURNERS
0.6000 LB/MMCF
0.0150 LB/MM3TU
0.0170 LB/MMBTU
0.0030 LB/MM3TU
0.1610 LB/retSTU
LOW NOX BURNERS
9.8300 LB/H
HOLMES STRETFORD UNIT

15.0000 LB/MMCF
17.0000 LB/MMCF
3.0000 LB/MMCF
161.0000 LB/MMCF
LC'ri NOX BURNERS
o.6ooo LB/M;:CF

0.0150 LB/MMBTU
0.0170 LB/MMBTU
0.0030 LB/i'MBTU
0.2500 LB/MMBTU
... « BASIS
... PCT EFF


99.00

99.00

99.00


50.00





30.00





30.00

99.60





30.00





NSPS
                                                          NOX
                                                                           HATER UASH OF RETORT OFF GAS TO REMOVE NH3
                                                                    0.2000 LB/MMBTU
97.00
NSFS
PAGE G- 533

-------
                                                                           WATER WASH OF RETORT OFF GAS TO REMOVE NH3       97.00
                                                          S02       0.1400 LB/mSTU
                                                                           REMOVE H£S BEFORE COMBUST.                       99.60
PAGE G- 534

-------
 (CONTINUED)  PARAHO DEVELOPMENT CORP.
  SUBJECT
FERMIT
THROUGHPUT
 CAPACITY
                                                        POLLUTANT    EMISSION LIMITS                                   ..  & BASIS
                                                         EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
 PACKAGE BOILER
 STORAGE TANKS,
                                     W.50 MM8TU/H
                                  53000.00 BBL
                     PM
                     S02
                     CO
                     VOC
 CRUDE SHALE OIL STORAGE TANKS, 7 150000.00 BBL
                                                           VOC
                                                           VOC
                                                                     Z. 0000 LB/MSAL
                                                                     0.5000 X S CONTENT
                                                                     5.0000 LB/MGAL
                                                                     1.0000 LB/MGAL
                                                                                              R°°P »
                                                                            EXT.  FLOAT.  ROOF W/F3IMARY 4 SEC.  SEAL
                                                                                                                             95.00
NOTES ---- ..... --

n21f_P«iIuIIATI°N IS F°R URGER BAGHOUSES ON CRUSHERS.  PUR.  GEN.  -  3 STACKS GAS TURBINE ft WASTE  HEAT BOILER EA.  BOILERS PROVI
DE 36.73X HEAT INPUT. 9 OTHER TANKS WILL CONTAIN EITHER  82  FUEL OIL,  PROPANE (CRYC3ENIC) , DIESEL FUEL OR
GASOLINE. NONE OF THEM SUBJECT TO NSPS. S02 EMISSIONS FROM  POWER GENERATION FACILITIES INCLUDE RETORT OFF GAS AND WASTE WATER
TREATE ACID GAS.
              DATUM WAS TRUNCATED  FOR  THIS TABLE.
                                                                                        REVIEW
PAGE G- 535
                                                     ID NUMBER UT-0024
                                                                                                          SOURCE TYPE CODE

-------
SOURCE TYPE/SIZE—-
                                             APPENDIX — DETAILED SOURCE LISTING
                            CRUDE OIL/NAT. GAS PRODUCTION (INCL. OIL SHALE)
                                                                                                                         05/22/1984
                                                                                               2.00 flEBL/D
COMPANY NAME/SITE LOCATION RIO BLANCO OIL SHALE-SI

DETERMINATION IS BACT FOR A MODIFIED SOURCE.
PERMIT NO.
DETERMINATION MftDE BY EPA REGION VIII
(AGENCY)
PROCESSES SUBJECT THROUGHPUT
TO THIS PERMIT CAPACITY
2 BOILERS 198.00 MV.BTU/H

HEATER 5.00 MMBTU/H

LUP.GI RETORT EOOO.OO BBL/D OIL S»





ORE CONV-STKPILE 4400.00 T/D SHALE


C°E TRANSFER 4400.00 T/D SHALE


ORE LOADOUT 4400.00 T/D SHALE


NEAR RANGE LY, CO



JOHN
( AGENCY



DALE
CONTACT PERSON)
POLLUTANT EMISSION LIMITS
EMITTED

NOX

NOX

NOX
S02

PM


PM


PM


PM

CONTROL EQUIPMENT

39.6000 LB/H

1.0000 LB/H

127.0000 LB/H
18.0000 LB/H
RETENTION
39.6000 LB/H
ESP

0.4000 LB/H
BAGHOUSE

0.4000 LB/H
BAGHOUSE

0.0800 LB/H
BAGHOUSE
RIO BLANCO COUNTY
DATE OF PERMIT ISSUANCE— 12/20/81
ESTIMATED DATE OF START-UP—
(3031-837-3763
(PHCME)
... * BASIS
OR PROCESS MODIFICATION ... PCT EFF

BACT

BACT

BACT
BACT

BACT
99.80

BACT
99.00

BACT
99.00

BACT
99.00
PAGE G- 536

-------
 (CONTINUED) RIO BUNCO OIL SHALE-ftl
PROCESSES SUBJECT
TO THIS PERMIT
PRIM.


PROC


PROC


SEC.


PROD.



CRUSH/SCR


SHALE TRANS., FEED


SHALE TPANS. DISP


CRUSH/SCR


GAS INC/SCRUB



THROUGHPUT
CAPACITY
4400.00


4400.00


4400.00


4400.00


70.00



T/D SHALE


T/D SHALE


T/D SHALE


T/D SHALE


MMBTU/H



POLLUTANT
EMITTED

Ptl


PM


PM


PM


S02

NOX
EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

0


0


0


0


9

24

.2400


.4000


.4000


.3200


.7000

.0000

LB/H
BAGHOUSE

LB/H
BAGHOUSE

LB/H
BAGHOUSE

LB/H
BASHOUSE

LB/H
SCRUE-BER
LB/H
... & BASIS
... PCT EFF

BACT
99.00

BACT
99.00

BftCT
99.00

BACT
99.00

BACT
SO. 00

NOTES 	

THREE YEAR OPERATION PLANNED.
(*) INDICATES DATUM WAS TRUNCATED  F03 THIS TABLE.


PAGE G- 537
                                                     ID NUMBER CO-0013
             INITIAL REVIEW  POST STARTUP
REVIEU STATUS;  04/01/1933

                  SOURCE TYPE CCDE   5.14

-------
                                              APPENDIX  — DETAILED  SOURCE  LISTING
                                                                                                                         05/22/198'+



 SOURCE  TYPE/SIZE---          CRUDE  OIL/HAT.  GAS  PRODUCTION  (INCL. OIL  SHALE)                    50.00  MMBTU/H
                            ——————	—	— —	— — — — — _ — — — _ — _ — _— _______	_._ ___	___	__-.__..	.._,.__	_..,	— _____	_	„__	

 COMPANY NAME/SITE  LOCATION   TEXAS  TAR SANDS,  LTD                                            LAPRYCR,  TX
                                                                                                                    MAVERICK COUNTY
                            	

 DETERMINATION IS BACT FOR A NEW SOURCE.                                                        DATE  OF PERMIT ISSUANCE--  06/24/82
 PE-MIT  NO. 9075                                                                                ESTIMATED  DATE OF  START-UP—   1932
 DETERMINATION MM3E BY        TEXAS  ACB                      JAMES CROCKER                       (512J-451-5711
                              (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHDNE)



 PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION LIMITS                                    ...  4 BASTS
 TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS  MODIFICATION   ...  PCT EFF
        	_		

 STEAM GENERATOR                      50.00  MMBTU/H
                                                           PM         0.0940 LB/MMSTU
                                                                            FABRIC FILTER                                    99.30
                                                           S02        1.2000 LB/Mr;3TU
                                                                            LIMESTONE INJECTION                              78 00
 COAL *  LIMESTONE STORAGE/HANDLI*
                                                           PM         1.3000 LB/H
                                                                            DUST CONTROL SYSTEM


NOTES 	
THIS IS A COAL FIRED SYSTEM. EMISSIONLIMITS ARE BACT,  DETERMINED BY TECHNOLOGY 4 ECONOMICS.











                                                                                                      INITIAL REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR  THIS  TABLE.                                         REVIEW STATUS:  04/01/J.933

PAGE G-  538                                           ID NUMBER  TX-OOS5                                    SOLACE TYPE CCDE   5.14

-------
                                              APPENDIX — DETAILED SOURCE LISTING
                                                                                                                          05/23/1934



 SOURCE  TYPE/SIZE—         CRUDE OIL/NAT.  GAS PRODUCTION (INCL. OIL SHALE)                    45.00 M5BL/0


 COMPANY NAME/SITE LOCATION  TOSCO OIL SHALE-1981                                      NEAR  BONANZA, UT
                                                                                                                       UINTAH COUNTY
                            » —— — — — -• — — — •»._____ __ __ _ __»_ _. «. — ••__•,_„. _ — _ _ — • — «, — «. — _» — ^»_ — — ™ — __.____._ _«._*.—.-»»•._ — — — .-._.-_.._...— .. _ _ „ ... ... . _ _.._.,___.. -,

 DETERMINATION IS BACT FOR A NEW SOURCE.                                                          DATE OF PERMIT ISSUANCE—  12/09/81
 PERMIT  NO.                                                                                       ESTIMATED DATE OF START-UP-
 DETERMINATION MADE BY       EPA REGION VIII                JOHN DALE                            <303 )-837-3763
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)

 — — — — — — — — — — — ——— — — — Z — ^ —»^~z~ir~~^ ~ s * ~ — t: Z — ~» —™^S™~ — ~~ ~ — — — — — — — — — — — — — — — — — — — — — •• — — — — — — — — — — — — -. — _ — ^ — _•_ — _«.____—.__ — _ »._ — — ——— — — •. — » — »»«.^»_^._ — „«.„

 PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... 4 BASIS
 TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT  OR  PROCESS MODIFICATION  ... PCT EFF
Z AUX BOILERS
FEED HEATER
MINE VENTS
OIL REEOILER
                                                            CO
                                                            NOX

                                                            PM
                                                            SOZ
CO
NOX
PM
SOS

PM
                                                            CO
                                                            NOX
                                                            PM
                                                            SOS
 2.9000 LB/H
18.0000 LB/H
        DESIGN
 3.2000 LB/H
 8.0000 LB/H
        LOW S COAL

 1.1000 LB/H
 7.0000 LB/H
 1.2000 LB/H
 3.1000 LB/H

10.6000 LB/H
14.9000 LB/H
        SETTLING

 1.5000 LB/H
 9.1000 LB/H
 1.6000 LB/H
 4.0000 LB/H
        LOW S FUEL
                                                                   BACT
                                                                   BACT

                                                                   BACT
                                                                   BACT
BACT
BACT
BACT
BACT

BACT
                                                                   BACT
                                                                   BACT
                                                                   BACT
                                                                   BACT
PAGE G- 539

-------
 (CONTINUED) TOSCO OIL SHALE-1981
PROCESSES SUBJECT
TO THIS PERMIT
ORE STORAGE


RECL TUNNEL


SEC CRUSHER


SPENT SHALE STOR


2 502 REC. PLANTS


4 REFORM FURN





6 ELUTRIATORS




6 PROCESS SHALE WET


THROUGHPUT POLLUTANT
CAPACITY EMITTED

PM


PM


PM

45.00 MB3L/D
PM


S02


CO
NOX
PM
S02


NOX
PM

S02

PM

= = - = = = = = = = - = = = = = = = = = = = = r: = = = = = = r = r = = = = = = r = rrz = = = r = "r =
EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

4.7000 LB/H
BAGHOUSE

6.2000 LB/H
BAGHOUSE

36.6000 LB/H
BAGHOUSE

7.9000 LB/H
WVTER

92.2000 LB/H
CLAUS iTAILGAS

10.8000 LB/H
90.3000 LB/H
12.0000 LB/H
30.1000 LB/H
LCU S FUEL

15.8000 LB/H
42.0000 LB/H
SCRUBBER
5.3000 LB/H

43.2000 LB/H
SCRUBBER
. . . « BASIS
... PCT EFF

BACT
99.70

BACT
99.70

BACT
99. 70

EACT
50.00

BACT
99.60

BACT
BACT
BACT
EACT


BACT
BACT
99.99
BACT

BACT
93.40
PAGE G- 540

-------
 {CONTINUED) TOSCO OIL SHALE-1981
 6 PREHEAT STK
                                       THROUGHPUT        POLLUTAHT     EMISSION  LIMITS                                    .. .  j BASIS
                                        CAPACITY          EMITTED            CONTROL EQUIPMENT  OR  PROCESS MODIFICATION  ...  PCT EFF
                                                           VOC     303.0000  LB/H                                              BACT
                                                                             INCINERATOR                                       85 00
                                                           NOX    1583.2000  LB/H                                              BACT
                                                           PM       90.0000  LB/H                                              BACT
                                                                             SCRUBBER                                          99 99
                                                           S02      62.5000  LB/H                                              EACT
                                                                             ABSORPTION                                        
-------
                                             APPENDIX -- DETAILED SOURCE LISTING
                                                                                                                        05/22/1984
 SOURCE TYPE/SIZE — -
                            CRUDE OIL/TUT. GAS PRODUCTION (INCL.  OIL SHALE)
                                                                                              10.00  KSBL/D
COMPANY NAME/SITE LOCATION  UNION OIL SHALE SI
                                                                                    NEAR  PARACHUTE,  CO
                                                                                                                   GARFIELD  COUNTY
DETERMINATION IS
PERMIT HO.
DETERMINATION MADE BY
                            EPA REGION VIII
                             (AGENCY)
   JOHN DALE
(AGENCY CONTACT PERSON)
DATE OF PERMIT ISSUANCE—  05/27/81
ESTIMATED DATE OF START-UP--
(303)-837-3763
    (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
H2 CHG HTR


DEARSENITER PURGE HTR


DEARSENITER CHARGE HTR


FRACT CHG HTR


REFORMER FURN


STEAM BOILER


THROUGHPUT POLLUTANT
CAPACITY EMITTED
24.00 MMSCFD
NOX


NOX


NOX


NOX


NOX


NOX

EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

2.8000 LB/H
DESIGN

1.8000 LB/H
DESIGN

2.3000 LB/H
DESIGN

2.5000 LB/H
DESIGN

53.1000 LB/H
DESIGN

12.0000 LB/H
DESIGN
... 4 BASIS
... FCT EFF

BACT


BACT


BACT


BACT


EACT


BACT
99.90
PAGE G- 542

-------
 (CONTINUED)  UNION OIL SHALE  81
           nUBJECT                    THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    . ..  4  BASIS

 _____            _                     CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION   ...  PCT  EFF



 SULFUR  REC.UNIT                      la.00 T/0

                                                           S02     300.0000 PPM                                               BACT
                                                                     1.9000 LB/H

                                                                            CLAUS&TAIL GAS                                    99.90
 NOTES
<*) INDICATES DATUM WAS TRUNCATED FOR THIS  TABLE.                                         REVIEW                            STA"TUP
r = = = - = ; = r = = = -::: = = = : = ::-=: = = = = = = : = - = _ = - = --- = _-__-____.___________________________________________

PAGE G- 543                                           10 NUMBER  CO-001^
                                                                                                           SOURCE TYPE CCDE

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/198*
SOURCE TYPE/SIZE—
                            CRUDE OIL/NAT. GAS PRODUCTION (IHCL.  OIL SHALE)
                                                                                          106000.00 BPSD
COMPANY NAME/SITE LOCATION  WHITE RIVER SHALE OIL CORP.
                                                                                           BONANZA) UT
                                                                                                                     UINTAH COUNTY
DETERMINATION IS BACT FOR A NEW SOURCE.
PERMIT NO. MAJ 053062-IT
DETERMINATION MADE BY       UTAH BAQ
                             (AGENCY)
                          CARL BROADHEAD
                       (AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE—  08/04/82
                                       ESTIMATED DATE OF START-UP—   1988
                                       (80D-533-6108
                                           (PHCME)
PROCESSES SUBJECT
TO THIS PERMIT
     THROUGHPUT
      CAPACITY
POLLUTANT    EMISSION LIMITS                                   . . . & BASIS
 EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
IN-MINE PRIMARY CRUSHING
CRUSHING 4 SCREENS
MINE CONVEYOR SURGE BIN
                                  89000.00 TPSD
                                 176000.00 TPSD
176000.00 TPSD
MINE CONVEYOR TRANSFER POINTS    176000.00 TPSD
FEED TO STORAGE SILOS
SURFACE CRUSHING t SCREENS
                                 176000.00 TPSD
                                 176000.00 TPSD
                                                           PM
                                                           PM
                                                           PM
                                                           PM
                                                           PM
                                                          PM
                                                                            WET SUPPRESSION
             0.0200 GR/DSCF
                    BAGHOUSE

             0.0130 6R/DSCF
                    BtGHOUSE

             0.0130 GR/DSCF
                    BAGHOUSE

             0.0130 G3/DSCF
                    BAGHOUSE

             0.0130 GR/DSCF
                    BAGHOUSE
                                                                                                                             80.00
                                                                                                                             99.70
                                                                                                                             99.70
                                                                                                                             99.70
                                                                                                                             99.70
                                                                                                                            99.70
PAGE G- 544

-------
 (CONTINUED) WHITE RIVER SHALE OIL CORP.
 PROCESSES SUBJECT
 TO THIS PERMIT
 CONVEYORS


 UNION RETORT SILO FEED


 SUPERIOR RETORT SILO FEED


 TOSCO RETORT SILO FEED
MAIN ACCESS ROADS
2ND LIGHT DUTY ROADS
•--========================================s=====-====-=.==s=-.=_==___._.__=___.__..:.__.=____.:__
THROUGHPUT POLLUTANT EMISSION LIMITS
CAPACITY EMITTED CONTROL EQUIPMENT OR PROCESS MODIFICATION
TRANSFER 900.00 TPSD
VE 20.0000 X OPACITY
WET SUPPRESSION
PM 0.0130 GR/DSCF
FULLY COVERED
46400.00 TPSD
PM 0.0130 GR/DSCF
ED mooo.00 TPSD W6HOOSE
PM 0.0130 GR/DSCF
BAGHCUSE
18500.00 TPSD
PM 0.0130 GR/DSCF
3 SHALE 39550.00 TPSD
VE 20.0000 X OPACITY
FULLY COVERED CONVEYORS
EYORSHA* 8.000.00 TPSD 20X MOISTURE
VE 20.0000 X OPACITY
FULLY COVERED CONVEYORS
20X MOISTURE
PM
PAVE
PAVINS
... 4 BASIS
... PCT EFF


80.00

90.00

99.70

99.70

99.70

99.00


99.00


95.00

                                                           PM
                                                                            MINIMIZE
                                                                            CHEMICAL SUPPRESSION
                                                                                                                             75.00
PAGE S- 545

-------
 (CONTINUED) WHITE RIVER SHALE OIL CORP.
PROCESSES SUBJECT THROUGHPUT POLLUTAN"
TO THIS PERMIT CAPACITY EMITTED.
TOSCO PROCESSED CONVEYOR SHALE 15000.00 TPSD
PM

PROCESSED SHALE CONVEYOR TRANSF* 149500.00 TPSD
VE

PROCESSED SHALE DISPOSAL 149500.00 TPSD
PM

LOAD IN 149500.00 TPSD
VE

GROOMING 112.00 SCRAPER H/D
VE

WIND EROSION 30.00 ACRE
PM

LOAD IN, RAW SHALE STOCKPILE 5000.00 TPSD
PM

LIVE STORAGE HIND EROSION, RAW * 175000.00 T
PM

GROOMING, RAW SHALE STOCKPILE 5000.00 TPSD
PM

F EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

MINIMIZE
20X MOISTURE COVERED CONVEYORS

20.0000 X OPACITY
15 X MOISTURE ENCLOSED

MINIMIZE
CHEM. DUST SUPPRES. COMPACT. ,REVEG.

20.0000 X MINIMIZE
15X HATER

20.0000 X OPACITY
WATERING

MINIMIZE
COMPACT. REVEG. 4 CHEM. DUST SUPPRES.

MINIMIZE
LCI.'ERING WELL

MINIMIZE
WATER SPRAYS

MINIMIZE
ViXTER SPRAYS
...» BASIS
... PCT EFF


99.00


99.00


85.00


60.00


50.00


85.00


75.00


50.00


50.00
DEAD STORAGE WIND EROSION, RAW *      2.80 MMT
PAGE G- 546

-------
 (CONTINUED) WHITE RIVER SHALE OIL CORP.
 PROCESSES SUBJECT
 TO THIS PERMIT
THROUGHPUT
 CAPACITY
POLLUTANT    EMISSION LIMITS
 EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION
& BASIS
PCT EFF
 PHASE III-UNION B RECYCLE GAS H*    960.00 MMBTU/H
 PHASE III - HYDRO TREATER REACT*    150.00 MWBTU/H
 TOSCO  PREHEAT  4  BALL  HEATERS
                                    479.00 MM3TU/H
BOILER 8 POWER PLANTS (3 STK)      3438.00 MMBTU/H
                     PM        0.0210 LB/KttBTU
                               5.0000 LB/H STACK
                     S02       0.0230 LB/MM3TU
                               5.5000 LB/H STACK
                                      TREATED GAS * UPGRADED SHALE OIL
                     NOX       0.0220 LB/Mf-IBTU
                              53.1000 LB/H STACK
                                      LOW NOX BURNERS

                     PM        0.0200 LB/MM3TU
                               2.6000 LB/H STACK
                     S02       0.1600 LB/MKBTU
                              10.0000 LB/H STACK
                                      CLEANED & TREATED  HIGH BTU FUEL GAS
                     NOX       0.2600 LB/M.'STU
                              39.0000 LB/H STACK

                     PM        0.0240 GR/DSCF
                              22.5000 LB/H STACK
                                      VENTL'31 SCRUBBER
                     S02        0.0020 GR/DSCF
                               0.5000 LB/H STACK
                                      TREATED FUELS
                     NOX        0.2200 GR/OSCF
                              51.9000 LB/H STACK
                                      LOU-NCX BURNERS
                                                           PM        0.0300 LB/r,t3TU
                                                                    73.2000 LB/H
                                                           S02       0.0700 LB.'KMBTU
                                                                   166.9000 LB/H
                                                                            FGD
                                                                            CLEANED & TREATED FUEL GAS,
                                                           NOX       0.2000 LB/HM5TU
                                                                   487.5000 LB/H
                                                                                                                              99.50
                                                                                                                              50.00
                                                                 UPGRADED SHALE  OIL
                                                                                       80.00
PAGE G- 547

-------
 (CONTINUED)  WHITE  RIVER  SHALE  OIL CORP.
 PROCESSES SUBJECT
 TO  THIS  PERMIT
 THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ...  * BASIS
  CAPACITY          EMITTED            CONTROL EQUIPMENT CR PROCESS MODIFICATION  ...'  PCT EFF
 Ha  PLANT REFORMER FURNACE
NAPTHA & CRUDE STORAGE TANKS

GAS TREATMENT PLANT, 3 UNITS




FUEL GAS TREATED HIGH BTU



FUEL GAS TREATED LOW BTU
                                    2058.00 MMBTU/H
28.00 MMBTU
                                                           PM

                                                           S02


                                                           NOX
                     S02
                     PM

                     NOX

                     H2S
                     T.S*
                     NH3

                     S
                     NH3
  0.2000 LB/MMBTU
 25.8000 LB/H
  0.0070 LB/MM3TU
  9.0000 LB/H
         CLEANED, TREATED & UPGRADED FUELS
  0.2100 LB/MMSTU
267.8000 LB/H
         LOW-NOX BURNERS

         FLOATING ROOF TANKS W/DBL SEALS

250.0000 PPMV AT OX 02

         TREATED HIGH BTU FUEL GAS
  0.1000 GR/DSCF
  0.4900 GR/DSCF
 10.0000 PPMV

 75.0000 PFMV
 10.0000 PFMV
                                                                                                                             25.00
NOTES 	
THE FEASIBILITY APPROVAL ORDER IS BASED ON BACT AS OF 1982.  THIS  IS A PHASE  CONSTRUCTION  PROJECT.  EACH UNIT OF  EACH  PHA^E HILL
 BE PERMITED BASED ON THE "THEN CUPRENT" BACT.  TPSD = TON PER  STREAM DAY
DIESEL FUEL SULFUR LIMIT - 0.20X BY WT. FUEL OIL - S = 20 PPMV ,  KH3 = 1500  PFMV.
{*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 548
                                                     ID.NUK3ER UT-0025
                                                                INITIAL REVIEW  POST STARTUP
                                                   REVIEW STATUS:   04/01/1953
                                                                     SOLACE TYPE CCDE   5.14

-------
                                              APPENDIX — DETAILED  SOURCE LISTING
                                                                                                                           05/22/1964
 SOURCE TYPE/SIZE—         OIL AND GAS FIELD SERVICE


 COMPANY NAME/SITE LOCATION  DRLGMUD CO.
                                   100000.00 LB/D
 DETERMINATION IS BACT FOR A NEW SOURCE.
 PERMIT NO.  X-3973
 DETERMINATION MADE BY       TEXAS ACS
                              (AGENCY)
   ROBERT MAUEL
(AGENCY CONTACT PERSON)
                                                                                                      TX
                                                                                                                    FORT  BEKD  COUNTY
DATE OF PERMIT ISSUANCE--   13/22/81
ESTIMATED DATE Or START-UP--    1932
(512 1-451-5711
    (PHONE)
           SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                         t  B.*
 ..-....„!.._.		   CAPACITY          EMITTED             CONTROL EQUIPMENT OR PROCESS MODIFICATION   .' '. '.  PCT  EFF
                                  "~~~~~""""~"~""'~~~**""™*~~~~"""""™"~ — ~~™*~~~"~~"~~^"""~~"~~*~"*'~~~~~*""~^'""- —— ••-•*- — »•• — — — » — •• — — — — — — —. — — _ — •.__»«»,„»__

 SILO  &  LOADING                    100000.00 LB/0
                                                            BAR*      0.1000  LB/H

 VENT  HOUSE  TRAFFIC                                                           SHOP MADE  FABRIC "LTER                           "-1°

                                                            PM        0.9000  LB/H


 NOTES 	


















[?^^TES_D^TUM_UASJRU*CATED FOR THIS TABLE.                                         REVIEW  STATUS™""^""  ™" ^"^

PAGE G- 5<+9                                            ID  Kur!BER  TX-0116                                  "~SOUSCE^TYPE~CraE~~~5~15

-------
                                              APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                         05/22/1984
 SOURCE TYPE/SIZE---
                             OIL AND  GAS  FIELD SERVICE
 COMPANY NAME/SITE  LOCATION  SIGMOR  PIPELINE CO.
                                                                                             306.00 MMGAL/YR
                                                                                       SAN ANTONIO, TX
                                                                                                                      BEXAR COUNTY
 DETERMINATION  IS BACT  FOR A NEW  SOURCE.
 PERMIT  NO.  6348
 DETERMINATION  MADE BY       TEXAS ACS
                              (AGENCY)
                       SAM CROWTHER
                    (AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE—  04/27/78
                                       ESTIMATED DATE OF START-UP--   1979
                                       (512)-451-5711
                                           (PHONE)
 PROCESSES SUBJECT
 TO THIS PERMIT
  THROUGHPUT
   CAPACITY
POLLUTANT    EMISSION LIMITS
 EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION
S BASIS
PCT EFF
GASOLINE LOADING 3 RACKS (12 SP*    306.00 MMGAL/YR
DIESEL/KERO LOADING


STORAGE TANKS (7)


FUGITIVE VOC
153.00 H-IGAL/YR


217.00 MGAL
   VOC      23.6000 T/YR
             0.1250 LB/MGAL VOC
                    CARSON ADSORPTION

   VOC      14.1000 T/YR
                    BOTTOM LOADING (SEE NOTE)

   VOC      25.0000 T/YR
                    INT. FLOAT COVERS,  WHITE TANKS

   VOC      12.0000 T/YR
                    NONE
  AP42

  97.50

  AP42
   0.00

  AP42
  97.00


   0.00
NOTES
CARBON ADSORPTION UNIT PURCHASE PRICE =$240,000  NOTE  -  BOTTOM  LOADING  IS CONSIDERED  UNCONTROLLED,  FUGITIVE  VOC  ESTIMATED  ONLY
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 550
                                                                 INITIAL REVIEW  POST STARTUP
                                                    REVIEW STATUS;  04/01/1933
                                                     ID NUMBER TX-008S
                                                                                                          SOURCE TYPE CODE   5.15

-------
                                              APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                         05/22/198*
 SOURCE TYPE/SIZE—-
 COMPANY NAME/SITE LOCATION  UNITED  GAS  PIPE  LINE CO.
                             OIL AND  GAS  FIELD SERVICE                                       2000.00 Hp EA>NAT- GASj
                                                                                          CARTHAGE, TX
                                                                                                                     PANDLA COUNTY
 DETERMINATION MADE  BY
TEXAS ACB
 (AGENCY)
                                                           J1H CARAMAY
                                                        {AGENCY CONTACT PERSON)
                                                                                                    °" PERMIT ISSUANCE-  05/07X80

                                                                                                              °*
                                                                                                   (PHONE)
                                      THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... 4 BASIS
 			"!ACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF

 SUPERIOR COMPRESSOR ENGINE         2000.00 HP
                                                           NOX       4.2000 G/BHP-H
                                                                            TU3BQCHARGED

 NOTES 	















<*> INDICATES DATUM WAS TPtWTATFn FPB  THT*  T4«fe                                         nrvrr,,        INITIAL  REVIEW  POST STARTUP
                                                                                        REVIEW
                                                     ID NUMBER TX-OOS4

-------
                                             APPENDIX ~ DETAILED SOURCE LISTING
                                                                                                                        05/22/1984
 SOURCE TYPE/SIZE—
                             PETROLEUM INDUSTRY — OTHER
COMPANY NAME/SITE  LOCATION  BEAR CREEK STORAGE
                                                                                         BIENVILLE, LA
                                                                                                                  BIENVILLE PARISH
DETERMINATION MADE BY
                            EPA REGION V!
                              ( AGENCY)
                                                           TOM DIGGS
                                                        (AGENCY CONTACT PERSON)
                                                                                               DATE OF PERMIT ISSUANCE-  09/22/79
                                                                                                              r*c t-r*nT i m
                                                                                                                 START-UP"
                                                                                                   (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
                                      THROUGHPUT        POLLUTANT    EMISSION LIMITS                                       t BASIS
                                       CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  . . '. PCT EFF
I.C. COMPRESSORi
GAS HEATERS, 3
REGENERATOR HEATERS, 3
                                   7000.00 HP EA
                                           UNKNOWN
                                           UNKNOWN
                                                           NOX      11.7000 6/HP-H
                                                                            AIR/FUEL RATIO
                                                           CO        1.4000 G/HP-H
                                                                            AIR/FUEL RATIO

                                                           NOX       2.1000 LB/H
                                                                            AIR/FUEL RATIO

                                                           NOX       0.4000 LB/H
                                                                            AIR/FUEL RATIO
                                                                                                                             BACT

                                                                                                                             BACT


                                                                                                                             BACT


                                                                                                                             BACT
NOTES
<»> INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.
==================:======:==r====rzrr=r=r=====rr=
PAGE G- 552
                                                                                        REVIEU
                                                     ID NUMBER LA-0023
                                                                                                          SGL'RCE TYPE CODE   5.16

-------
                                             APPENDIX -- DETAILED SOURCE  LISTING
                                                                                                                         05/22/1984
 SOURCE TYPE/SIZE — -
                             PETROLEUM  INDUSTRY — OTHER
                                                                                          525600.00 MMGAL/YR
 COMPANY NAME/SITE LOCATION  CHEVRON USA, INC.
                                                                                                    UT
                                                                                                                      DAVIS COUNTY
 DETERMINATION IS  BACT  FOR  A  MODIFIED SOURCE
 PERMIT NO.
 DETERMINATION MADE  BY        UTAH BAQ
                              (AGENCY)
                     DONALD ROBINSON
                  (AGENCY CONTACT PERSON)
DATE OF PERMIT ISSUANCE—  07/08/82
ESTIMATED DATE OF START-UP--   1933
(8011-533-6108
    (PHONE)
 PROCESSES  SUBJECT
 TO  THIS  PERMIT
THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... 4 BASIS
 CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
SEPARATOR
                                    525.60 MMGAL/YR
                                                           VOC
                                                                            STEEL COVER-TOTAL
                                                                                                                             95.00
NOTES 	
AIR TIGHT STEEL COVER PLATES OVER THE ENTIRE SEPARATOR.
(») INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 553
                                                                INITIAL  REVIEW   POST STARTUP
                                                  REVIEW STATUS:   C4/01/1933     OZ/13/19S4
                                                      ID  NUMBER  UT-002S
                                                                                                           SO'JSCE TYPE CODE   5.16

-------
                                              APPENDIX  -- DETAILED  SOURCE LISTING
                                                                                                                         05/22/1984



SOURCE TYPE/SIZE—          PETROLEUM INDUSTRY  ~ OTHER
                            ~~™~l~~""'™—— — «• — — "'•" — — —-"'— — — — — — — — •— — — — — — — — — — — — — -.-. — .»_ _______ _ .__ ______ — ••_„«> ——-. __ — „ — ,. — _.»•.• ___ — — — — — » — — — •_^_™«,___

COMPANY NAME/SITE  LOCATION   COLORADO  INTERSTATE GAS                                COLORADO SPRINGS,  OK 80944
                             P.O.  BOX  1087
                            	•	

DETERMINATION IS BACT  FOR A NEW SOURCE.                                                        DATE  OF PERMIT ISSUANCE—  02/26/81
PERMIT NO. (REGION FILE NO.) PSD-OK-358                                                        ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY        EPA REGION VI                  JOE WINKLER                         (214)-767-1594
                             (AGENCY)                   (AGENCY CONTACT  PERSON)                     (PHONE)



PROCESSES SUBJECT                      THROUGHPUT        POLLUTANT    EMISSION  LIMITS                                   ...  8 BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL  EQUIPMENT OR  PROCESS MODIFICATION  ...  PCT EFF
COMPRESSOR ENGINE
                                   2700.00 HP
EMERGENCY GEN.
                                    370.00 HP
NOX

CO

soa

VOC

PM


NOX

CO

S02

VOC

PM
 0.0010 G/HP-H
        TUHBOCHARGED CLEAN BURN
 0.0010 G/HP-H
        EFFICIENT COMBUSTION
 0.0010 G/HP-H
        EFFICIENT OPERATION
 0.0010 G/HP-H
        EFFICIENT COMBUSTION

        EFFICIENT COMBUSTION

10.9000 G/HP-H
        NORMAL OPERATION
 1.4000 G/HP-H
        NCSfl-'.L OPERATION
 0.0010 G/HP-H
        NORMAL OPERATION
 0.8400 G/HP-H
        NORMAL OPERATION

        NCP.HAL OPERATION
BACT

BACT

BACT

BACT

BACT


BACT

BACT

BACT

EACT

BACT
PAGE G- 554

-------
 (CONTINUED) COLORADO INTERSTATE GAS
PROCESSES SUBJECT THROUGHPUT POLLUTANT
TO THIS PERMIT CAPACITY EMITTED
801 LER 2.60 MM8TU/H
NOX

CO

S02

VOC

PM
EMISSION LIMITS . . . S BASIS
CONTROL EQUIPMENT OR PROCESS MODIFICATION ... PCT EFF

0.3200 LB/H
NORMAL OPERATION
0.0500 LB/H
NORMAL OPERATION
O.OOZO LB/H
NORMAL OPERATION

NORMAL OPERATION
0.0130 LB/H

BACT

BACT

BACT

BACT

BACT
                                                                             NORMAL OPERATION
 NOTES  	
 OPERATED  ONLY DURING POWER OUTAGES. BOILER OPERATED ONLY DURING COLD WEATHER.
                     IAS TRUNCATED FOR THIS TABLE.                                         REVIEW
PACE R_ ccc                                            ,_  ,,
rMJl- ^>  ->jj                                            T n  *Fi '  . ij  ,  _ i .•, ^.
                                                                                                             SCJxCE TYPE CCDE   5.16

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/23/1984



SOURCE TYPE/SIZE—         PETROLEUM INDUSTRY — OTHER


COMPANY NAME/SITE LOCATION  HOUSTON PIPE LINE CO.                                          HOUSTON, TX 77001
                            HOUSTON NAT. GAS BLDG 14TH FL.


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE—  04/30/81
PERMIT NO. TX-313                                                      .                        ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY       EPA REGION VI                  JOHN BUNYAK                         <214 )-767-1594
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... * BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT 07?  PROCESS MODIFICATION  ... PCT EFF


I.C. ENGINES, 4 TURSO.             2400.00 HP EA
                                                           NOX      60.8000 LB/H                                             BACT
                                                                    11.5000 G/HP-H
                                                                            AIR/FUEL RATIO CONTROL
DEHYDHATORS, 2                        1.25 MMBTU/H EA
                                                           NOX       0.1500 LB/H                                             BACT
                                                                     0.1200 LB/ttt!BTU
                                                                            COMBUST. CONTRL, EFF.  DESIGN


NOTES 	
EACH OF THE I.C. ENGINES WERE LIMITED TO 0.65 G/HP-H FOR CO,  HOWEVER, POLLUTANT WAS NOT REVIEWED  UJJDER PSD.











                                                                                                      INITIAL P.JVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:   04/01/1933

PAGE G- 556                                           ID NUMBER TX-00/6                                   SOURCE  TYPE CODE   5.16

-------
                                              APPENDIX — DETAILED SOURCE LISTING
 SOURCE TYPE/SIZE—         PETROLEUM INDUSTRY — OTHER
                                   "" ~"~ ~"~" ~ -" — — — — — — — — — —.-__.— ___.___„.__ ,^,_ — __. __ _ __.»____,_____ _ — _ _ _ __. _ — — — .. — — -, — _—..-._»__ __ .,_ __ _ __ — _— « .__„ ,»-_ — ___ — _

 COMPANY NAME/SITE LOCATION  OASIS PIPELINE CO.                                             HOUSTON,  TX 77001
                             1200 TRAVIS, BOX 1188


                       FOR * MODIFIED SOURCE-                                                   »*TE  OF PERMIT ISSUANCE-  10/06/80
 DETERMINATION MADE BY       EPA PESION VI                  JOHN BUNYAK
                              (AGENCY)                   (AGENCY CONTACT PERSON)                    ( PHCNE )



                                       THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    . . . 4 BASIS
               ___________              CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  . . . PCT EFF

 COMPRESSOR  ENGINE                  1350.00 HP EA
                                                            NOX       6.8600 G/HP-H                                            BACT
                                                                             LOW EX. AIR -- AIR/FUEL  RATIO                     37 00
                                                            VOC       0.7000 G/HP-H                                            BACT
                                                                             EFFICIENT COMBUSTION
                                                            CO        1.4000 G/HP-H                                            BACT
                                                                             EFFICIENT COMBUSTION

NOTES  — ........














l:L^^^nL^I^=^!J^^I^=^!_I^!.^Bb!: ____________________________

PAGE G' 55?                                           10 N^SER  TX-003S

-------
                                             APPENDIX  — DETAILED  SOURCE  LISTING
                                                                                                                       05/22/193*
SOURCE TYPE/SIZE —
                            PETROLEUM INDUSTRY  —  OTHER
COMPANY NAME/SITE LOCATION  ODESSA NATURAL CORP.
                                                                                            CISCO, TX
                                                                                                                  EASTLAND COUNTY
DETERMINATION IS BACT FOR A MODIFIED SOURCE.
PERMIT NO. (REGION FILE NO.) PSD-TX-36S
DETERMINATION HADE BY       EPA REGION VI
                             (AGENCY)
     BILL TAYLOR
  (AGENCY CONTACT PERSON)
                                         DATE OF PERMIT ISSUANCE—  03/02/81
                                         ESTIMATED DATE OF START-UP--
( PHONE )
PROCESSES SUBJECT
TO THIS PERMIT
TURBINE




I. C. ENGINES, 2 EA



THROUGHPUT POLLUTANT
CAPACITY EMITTED
7660.00 HP
NOX

CO

1560.00 HP
NOX

CO
EMISSION LIMITS
CONTROL EQUIPMENT OR PROCESS MODIFICATION

1.3000 G/HP-H
AIR/FUEL RATIO
0.5000 G/HP-H
AIR/FUEL RATIO

6.5000 G/HP-H
AIR/FUEL RATIO
2.2000 G/HP-H
... i BASIS
... PCT EFF

BACT

BACT


BACT

BACT
                                                                           AIR/FUEL RATIO
NOTES
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 55S
ID NUMBER TX-0028
                                                INITIAL REVIEW  POST STARTUP
                                   REVIEW STATUS:   0^/01/1933
                                                     SOURCE TYPE CCDE   5.16

-------
                                              APPENDIX  — DETAILED SOURCE  LISTING
                                                                                                                        05/22/198"+
 SOURCE TYPE/SIZE—         PETROLEUM INDUSTRY — OTHER


 COMPANY NAME/SITE LOCATION  PANHANDLE EAST.  PIPELINE
                                                                                              ALVA, OK
                                                                                                                      WOODS COUNTY
 DETERMINATION IS BACT FOR A MODIFIED  SOURCE
 PERHIT NO.  (REGION FILE NO.) PSD-OK-330
 DETERMINATION MADE BY       EPA  REGION VI
                              (AGENCY)
                     BILL TAYLOR
                  (AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE—  05/29/81
                                       ESTIMATED DATE OF START-UP--
                                       (214 1-767-1594
                                           (PHONE)
 PROCESSES SUBJECT
 TO THIS  PERMIT
 I.C.  ENGINE,  3  EA
 I.C. ENGINE
THROUGHPUT
 CAPACITY
                                   4500.00 HP
                                    631.00 HP
POLLUTANT    EMISSION LIMITS
 EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION
                     NOX        6.0000  G/HP-H
                                      AIR/FUEL  RATIO
                     CO         4.8000  G/HP-H
                                      AIR/FUEL  RATIO

                     NOX      11.5000  G/HP-H
                                      AIR/FUEL  RATIO
                     CO         5.5000  G/HP-H
                                      AIR/FUEL  RATIO
& BASIS
FCT EFF
                                                                     BACT

                                                                     BACT


                                                                     BACT

                                                                     BACT
NOTES
<»> INDICATES DATUM WAS TRUNCATED  FOR  THIS  TABLE.

PAGE G- 559
                                                               INITIAL REVIEW  POST STARTUP
                                                  REVIEW STATUS;  04/01/1933
                                                     ID NUMBER OK-0003
                                                                                                          SOURCE TYPE CODE   5.16

-------
                                             APPENDIX — DETAILED  SOURCE  LISTING
                                                                                                                         05/22/1984



SOURCE TYPE/SIZE—         PETROLEUM  INDUSTRY -- OTHER
                           — — — — — — —— — — — —	— — — — — —	— — — — — -. — — — — — — — — — — _-.— — •.— _._ — __ — — _«. — — —	— — — — — _ — — — — — — _—.«._-. —	— — — .. — — _-.—.	-. — — — — _— — — —,— _ — _

COMPANY NAME/SITE LOCATION  PANHANDLE  EAST. PIPELINE                                        CASHION,  OK
                            CASHION STATION                                                                       KINGFISHER COUNTY
                           — — —	— — — — — —	— — —	—	— — — — — — — — — — — _. — — ,_—. — _.».— ...— — „. — — ,.. — _.. — ,_„ — ____..__..	— — — — —	_ — — —	_,	_	_ _„	.	_

DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE  OF PERMIT ISSUANCE—  05/08/81
PERMIT NO. (REGION FILE NO.) PSO-CK-329                                                         ESTIMATED DATE OF START-UP--
DETERMINATION MADE BY       EPA RESICH VI                  JOHN BUNYAK                          (214)-767-1594
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE )



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ... * BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
— — — — —«-———•— — — — — — — ^™ — — ———— — — — — — wv. _ — IB _ . _ V •. _ ^ — — —— — — _—v— ,» _ — — — — „. —. — — _ — — ^— — — — i— — — _. — — — _— —»—^^— _«.„_„._•.-— _ — — _— — — _— — _— — — _ — — _ — — ... • — _•.— ... _ _ __ _ „.

I. C. ENGINE, 2 EA                 4500.00 HP
                                                           NOX       9.0000 G/HP-H                                           BACT
                                                                            AIR/FUEL  RATIO
                                                           CO        9.0000 G/KP-H                                           BACT
                                                                            AIR/FUEL  RATIO


NOTES		-
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 560
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS:  0^/01/1933
                                                      ID NUMBER OK-0009
                                                                                                            SOURCE  TYPE  CODE    5.16

-------
                                              APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                         05/22/l
-------
                                              APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                          05/22/19S1*



 SOURCE  TYPE/SIZE-—         PETROLEUM INDUSTRY — OTHER
                            — ~ — ~™~~* — """^™"""~"""""'''"~"*"~~~~™I'~"~~™""1~*"~ — ~~'~""1~""-""*~ — ™ —•» — — • — "• — — ••'••"—™ —— •" — «» — — — — --• — — — — •-• — — •— — •• — — — — — — — — — ..___™.__,. —_„.__„__.

 COMPANY NAME/SITE LOCATION  PANHANDLE EAST. PIPELINE                                               , TX 64141
                             6 KM SW GARNER OIL FD.                                                                    CARSON COUNTY
                            — •"• — —	— — —	—	—	— — -,_» —— _ — — _„__ — — — — .. — __..______,.__________________	 __________	,_	_______

 DETERMINATION  IS  BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE--  02/11/81
 PERMIT  NO.  (REGION FILE  NO.) PSD-TX-320                                                        ESTIMATED DATE OF START-UP--
 DETERMINATION  MADE BY       EPA REGION VI                  JOHN BUNYAK                          (214j-767-1594
                              (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



 PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ...  S BASIS
 TO THIS  PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ...  PCT EFF
COMPRESSOR ENGINE
                                     771.00 HP EA
                                                            NOX      11.5000 G/HP-H
                                                                             AIR/FUEL RATIO
                                                            VOC      13.5000 LB/H
                                                                             EFFICIENT COMBUSTION-
                                                            CO        5.7000 G/HP-H
                                                                             EFFICIENT COMBUSTION
                                                            NH3       0.6800 LB/H
                                                                             EFFICIENT COMBUSTION
                                     BACT

                                     BACT

                                     BACT

                                     BACT
NOTES 	
AIR/FUEL RATIO WITH A RESULTANT  Z7.  FUEL SACRIFICE
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 562
             INITIAL REVIEW   POST STARTUP
REVIEW STATUS:  04/01/1933
                                                      ID NUMBER TX-0044
                                                                                                            SOURCE TYPE CCDE   5.16

-------
                                              APPENDIX — DETAILED SOURCE LISTING

 = = r = = = = = = -rr = r= = = r = = = rrr = = r = = ___________________________         _       _                                               05/32/1934


 SOURCE TYPE/SIZE—         PETROLEUM INDUSTRY — OTHER
                            --- ""* ---- -.-_--- -- _ ----- , -- :_ ---- -- — - — - — -- — _ — _»___«.___.^«
                                                                                ^*"™*"~~*-~*' — ~ — — — *-•• — — — —• — — «» — '•- — — — — — — -« — — •». — •. — — »_«. — »._ — .» — _

 COMPANY NAME/SITE LOCATION  PANHANDLE EAST. PIPELINE                                      AMARILLO, TX

                                                                                                                       CARSON COUNTY


                                                                                                DATE OF PERMIT  ISSUANCE-  02/11/61

 DETERMINATION MADE BY       EPA RESION VI                   TOM DIGSS                           ?f™™-2S  * START'UP"
                              (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)

                                       === ==^===== = ^======== ============^===========^= ._... _____ ==.. = ... = ......._._......„.„._..

                                       THROUGHPUT         POLLUTANT    EMISSION LIMITS                                        4 BASrs
 __...___„__._ .........             CAPACITY           EMITTED            CONTROL EQUIPMENT OH PROCESS MODIFICATION  .'.'.  PCT EFF
                                         *"~""""~~~'~~   --*- — - — ----- — — -- — -- — -*-» — ----------^--_--_«- --- ------—-_ — _-_*_„_. -- _--__»___»_._

 I.C. ENGINES, 3                      771.00 BRAKE  HP EA
                                                            NOX      11.5000 G/HP-H                                            BACT
                                                                             AIR/FUEL RATIO
                                                            CO        5.7000 G/HP-H                 -                           BACT
                                                                             AIR/FUEL RATIO


NOTES -----------
                                      THIS TA8LE-
                                                                                                                       POST STARTUP

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/32/1934
= = = = = = r = = r = = = = = = = = = r = = = = = = r: = rz = = = == = r = === = = = = = = = = = = = = = = = = = === = = = = = = = = = = = = = = = = = = = === = = = = = = ==== = = = = = = = = = = = = -== = = = === === = :: = :: = ::-::: = -- =


SOURCE TYPE/SIZE—         PETROLEUM INDUSTRY — OTHER


COMPANY NAME/SITE LOCATION  PETRO-LEWIS CORP.                                                     ' CA


DETERMINATION IS LAER FOR A NEW SOURCE.                                                        DATE OF PERMIT ISSUANCE-  02/23/84
PERMIT NO. 4052033-037                                                                         ESTIMATED DATE OF START-UP--
DETERMINATION MADE BY       KERN COUNTY APCO               TOM PAXSOM                          (605)-861-3682
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHCME>



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... PCT EFF
	_	'--------

GENERATOR, STEAM, 5 EA               62.50 MMBTU/H
                                                           PM        0.0340 LB/MMBTU
                                                                    50.6600 LB/D
                                                                            KET SCRUBBER                                     61.00
                                                           SOX       0.0230 LB/MM3TU
                                                                    34.8100 LB/D
                                                                            VENTURI SCRUBBER                                 30.00
                                                           NOX       0.1200 LB/tt3TU
                                                                   181.3000 LB/D
                                                                            STAGED COMBUSTION                                70.00


NOTES 	











                                                                                                       INITIAL REVIEW  POST STARTUP
 (*l  INDICATES DATUM WAS  TRUNCATED  FOR  THIS  TABLE.                                        REVIEW STATUS'-
 	= -- = = - = = = = r = rrr = = rr = : = :r = r = = = = : = = = = = rr = = = = = = = = = = = = = = = = = = : = = = = = = = = = = = = = = = = = = = = = = = - = = = = ::::: = = = = = = = = = =
 PAGE~G-~564ID NUf1BER CA-0053                                    SOURCE TYPE CODE   5.16

-------
                                            APPENDIX  — DETAILED SOURCE  LISTING
                                                                                                                        05/22/198'*
SOURCE TYPE/SIZE—         PETROLEUM INDUSTRY  — OTHER


COMPANY NAME/SITE LOCATION  REFINERY WASTE  GAS  RECOVERY                                            , CA
                                                                                                                       KERN COUNTY


DETERMINATION IS                                                                              DATE OF  PERMIT ISSUANCE—   03/19/S4
PERMIT NO. SEE NOTE                                                                           ESTIMATED  DATE OF  START-UP-
DETERMINATION MADE BY       KERN COUNTY APCD                TOM  PAXSON                          (8051-861-3682
                             (AGENCY)                   (AGENCY CONTACT  PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT         POLLUTANT    EMISSION LIMITS                                   ... *  BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL  EQUIPMENT OR  PROCESS  MODIFICATION  ... PCT  EFF


VAPOR COMPRESSOR, VALVES, * FLA* 720000.00  SCF/D
                                                           VOC       28.9000  LB/D
                                                                            I & M TO MINIMIZE FUG.  EMIS.                      65.00


NOTES 	
NOTE -- PERMITS NUMBERS 2018008A, 2018012B, 2018046A,  2018062.  SOURCE  WILL OPERATE 24 H/D,  7 D/WEEK,  52 WEEK/YR.
















                                                                                                      INITIAL F^VIEW  POST STARTUP
<*) INDICATES DATUM WAS TRUNCATED FOR THIS  TABLE.                                         REVIEW  STATUS--

PAGE G- 565                                           ID NUMBER CA-0065                                     SOURCE TYPE CODE   5.16

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                         05/22/1984



 SOURCE TYPE/SIZE—          PETROLEUM  INDUSTRY — OTHER                                     8200.00 BBL/D


 COMPANY NAME/SITE  LOCATION   SHELL OIL  CO.                                                          , US 70161
                                                                                                                       PIKE COUNTY


 DETERMINATION IS BACT FOR A  MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE—  09/17/80
 PERMIT NO. MS 025                                                                              ESTIMATED DATE OF START-UP-
 DETERMINATION MADE BY        MISSISSIPPI DK'R                DUIGHT WILEY                        (601 )-35
-------
                                            APPENDIX — DETAILED SOURCE LISTING
                                                                                                                       05/22/1934



SOURCE TYPE/SIZE—-         PETROLEUM INDUSTRY  — OTHER


COMPANY NAME/SITE LOCATION  SOUTHERN NAT.  GAS                                            BIENVILLE,  LA
                            BIENVILLE                                                                            BIENVILLE  PARISH


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE  OF  PERMIT  ISSUANCE—   09/11/81
PERMIT HO. (REGION FILE NO.) PSO-LA-406                                                        ESTIMATED  DATE  OF  START-UP--
DETERMINATION MADE BY       EPA REGION VI                  BILL TAYLOR                         (214)-767-15<54
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT         POLLUTANT     EMISSION LIMITS                                    ...  S BASIS
TO THIS PERMIT                        CAPACITY         EMITTED             CONTROL EQUIPMENT OR PROCESS  MODIFICATION  ...  PCT EFF


I.C. ENGINES, Z EA                  448.00 BRAKE HP
                                                          NOX       11.0000  G/HP-H                                            BACT
                                                                            AIR/FUEL  RATIO


NOTES 	
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 567
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS:  04/01/1953
                                                      ID  NUMBER  LA-0009
                  SOURCE TYPE CODE   5.16

-------
                                             APPENDIX — DETAILED  SOURCE  LISTING
                                                                                                                         05/22/1984



SOURCE TYPE/SIZE—          PETROLEUM  INDUSTRY — OTHER
                            — — — — — — «• — —— — — — — — — — — — ——— — «-———— ^ — — «- — — —— — — — — ^ — —— — » — — — — — -.— — — — —-^ — «, — —• — — «.-.«.—.«..._ — — !_—.» — — — —^--^ ™._» — _^— — _ — __ — —_ — __„

COMPANY NAME/SITE LOCATION  SOUTHERN NAT. GAS                                           FRANKLINTON, LA
                                                                                                                  WASHINGTON PARISH


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE OF PERMIT ISSUANCE—  07/17/80
PERMIT NO. (REGION FILE NO.) PSD-LA-267                                                         ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY       EPA REGION VI                  JOHN BUNYAK                          1214)-767-159<+
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                    ...  t BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT  OR  PROCESS MODIFICATION  ...  PCT EFF
- — —	- — — — — — — -. — — •. — — _-.-._-. — _ — — — _ — • — — — _-. — _ — — ___ — — __»_«»_«._ «.«.-. — ^ — — _ — — _-. «_ —._ —___«__«._ —« —_w —__ —»^-.____w.-.-1.	„___ _ — _-._,..	_„_ — _„_.»...._ •_. __

I.C. ENGINE                        5000.00 HP
                                                           NOX     182.0000 LB/H                                             BACT
                                                           CO        <+.0000 LB/H                                             BACT
                                                                            AIR/FUEL  RATIO


NOTES 	
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 563
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS:  04/01/15S3
                                                      ID NUMBER LA-0021
                                                                                                            SOURCE  TYPE  CODE    5.16

-------
                                             APPENDIX —  DETAILED  SOURCE LISTING
                                                                                                                        05/22/196*
SOURCE TYPE/SIZE —
                            PETROLEUM INDUSTRY ~  OTHER
COMPANY NAME/SITE LOCATION  SUN GAS CO.
                            THREE NORTH PARK EAST ST.
                                    DALLAS, TX
DETERMINATION IS BACT FOR A MODIFIED SOURCE.
PERMIT NO. (REGION FILE NO.) PSD-TX-R72
DETERMINATION MADE BY       EPA REGION VI
                             (AGENCY)
   JOHN BUNYAK
(AGENCY CONTACT PERSON)
                                       DATE OF PERMIT ISSUANCE—  02/26/81
                                       ESTIMATED DATE OF START-UP—
                                                                                                   ( PHONE )
PROCESSES SUBJECT                     THROUGHPUT         POLLUTANT     EMISSION LIMITS                                   . . .  & BASIS
TO THIS PERMIT                         CAPACITY           EMITTED             CONTROL EQUIPMENT OS  PROCESS MODIFICATION  ...  PCT EFF


COMPRESSOR ENGINE, 2               1200.00  HP
                                                          NOX       9.1000  G/HP-H                                            BACT
                                                                            AIR/FUEL RATIO,IGNITION RETARD
                                                          CO         1.2000  G/HP-H                                            BACT
                                                                            AIR/FUEL RATIO,IGNITION RETARD
COMPRESSOR                          600.00  HP
                                                          NOX       9.1000  G/HP-H                                            BACT
                                                                            AIR/FUEL RATIO,IGNITION RETARD
                                                          CO         1.2000  G/HP-H                                            BACT
                                                                            AIR/FUEL RATIO,IGNITION RETARD


NOTES 	










                                                                                                      INITIAL REVIEW  POST  STARTUP
<*) INDICATES DATUM WAS TRUNCATED FOR  THIS  TABLE.                                         REVIEW STATUS:   04/01/1933

PAGE G- 569                                           ID  N'JMSER TX-OC26            ,                         SO'JRCE  TYPE CODE   5.16

-------
                                             APPENDIX —  DETAILED SOURCE LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE-—         PETROLEUM INDUSTRY —  OTHER


COMPANY NAME/SITE LOCATION  TEXACO, INC.                                      EAST COTE  BLANCHE BAY,  LA
                                                                                                                     IBERIN  PARISH


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE  OF  PERMIT  ISSUANCE—   07/30/81
PERMIT HO. (REGION FILE NO.) PSD-LA-382                                                       ESTIMATED  DATE  OF  START-UP-
DETERMINATION MADE BY       EPA REGION VI                  JOHN BENHAM                        (214)-767-1594
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION LIMITS                                    ...» BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS  MODIFICATION  ... PCT EFF


I.C. ENGINE 8                      1560.00 BRAKE HP
                                                           NOX       10.0000  G/HP-H                                          BACT
                                                                            AIR/FUEL  RATIO
I.C. ENGINE 1                        40.00 BRAKE HP
                                                           CO        10.0000  G/HP-H                                          BACT
                                                                            AIR/FUEL  RATIO


NOTES 	














                                                                                                     INITIAL  REVIEW  POST STARTUP
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:   04/01/1933

PAGE G- 570                                           ID  NUMBER LA-001E                                   SOURCE TYPE CODE   5.16

-------
                                             APPENDIX — DETAILED SOURCE  LISTING
                                                                                                                       05/22/1984



SOURCE TYPE/SIZE—-         PETROLEUM INDUSTRY  — OTHER


COMPANY NAME/SITE LOCATION  TEXACO,  INC.                                               NEW ORLEANS,  LA  70160
                            P.O. BOX 60252


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE  OF  PERMIT  ISSUANCE--   07/27/81
PEPMIT NO. (REGION FILE NO.) PSD-LA-381                                                       ESTIMATED  DATE  OF  START-UP-
DETERMINATION MADE BY       EPA REGION VI                  JOHN  BUNYAK                         (21
-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984
SOURCE TYPE/SIZE	         PETROLEUM INDUSTRY -- OTHER                                     6300.00 HP


COMPANY NAME/SITE LOCATION  TEXACO, INC.                                               NEW ORLEANS, LA
                            1501 CANAL ST., P.O. BOX 60252
                           •	——————	———————————— —— —	—	— „. — — ..— — — _.. — — ,-,_..— — .._..— — — — — — .. — — — — — — — — — — — — — — — — — — — — — — — — — — —*- — —	— — — — — — — — — — — — — — —

DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE OF PERMIT ISSUANCE—  08/Z9/80
PERMIT NO. (REGION FILE NO.) FSD-LA-301                                                        ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY       EPA REGION VI                  JOHN BUNYAK                         (214)-767-1594
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ... t BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR PROCESS MODIFICATION  ... FCT EFF
___._ — _ — _ — _ — — — — — — — — — — — — — — — _ — — — _ — — — .. — — — .* — — — —	~ — — —	— — — — — — — — — —	— — — — — — — — — — — — — — — — — — — -, — »• — — «»	— — — —	— —	— — —	. — — — — — — —— — — -.— — — — — — — — — — — — ..—

ENGINE, I.C., TURBOCHARGED         2650.00 HP
                                                           NOX      43.7000 LB/H                                             BACT
                                                                     7.5000 G/HP-H
                                                                            IGN. TI. RETARD ENG. SPARK
TURBINE COMPRESSOR, GAS-FIRED      3300.00 HP
                                                           NOX       9.4000 LB/H                                             NSPS
                                                                     1.3000 G/HP-H
I.C. ENGINE, NAT. ASPIRATED         350.00 HP
                                                           NOX       7.7000 LB/H                                             BACT
                                                                    10.0000 G/HP-H
                                                                            AIR/FUEL RATIO CONTROL


NOTES 	









                                                                                                      INITIAL REVIEW  POST STARTUP
<*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEU STATUS:  04/01/1033

PAGE G- 572                                           ID NUMBER LA-0033                                    SG'JRCE T1PE CODE   5.16

-------
                                             APPENDIX -- DETAILED SOURCE LISTING
                                                                                                                        05/22/198*
 SOURCE TYPE/SIZE—
                             PETROLEUM INDUSTRY — OTHER
COMPANY NAME/SITE LOCATION  TEXACO,  INC.
                            1501 CANAL ST
                                                                                       NEW ORLEANS, LA 70160
DETERMINATION IS BACT FOR A MODIFIED SOURCE.
PERMIT NO. (REGION FILE NO.) PSD-LA-300
DETERfUNATION MADE BY       EPA REGION VI
                             (AGENCY)
                                                           JOHN BUNYAK
                                                        (AGENCY CONTACT  PERSON)
                                                                                               DATE OF PERMIT ISSUANCE--  08/29/80
                                                                                               ESTIMATED DATE OF START-UP—
                                                                                               ( 214 )-767-159<+
                                                                                                   (PHONE)
PROCESSES SUBJECT
TO THIS PERMIT
                                      THROUGHPUT        POLLUTANT     EMISSION  LIMITS
                                       CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS  MODIFICATION
                                                                                                                       ... & BASIS
                                                                                                                       ... PCT EFF
I. C. ENGINE, TURBOCHARGED
I. C. ENSINE, TURBOCHARGED
I. C. ENGINE, NAT. ASPIRATED
                                   2650.00 HP
                                   2650.00 HP
TURBINE, GAS FIRED, COMPRESSION    3500.00 HP
                                    500.00 HP
                                                          NOX       7.5000 G/HP-H
                                                                   43.7000 LB/H
                                                                           CON IGN TIM/RETARD ENGINE SPARK

                                                          NOX       7.5000 G/HP-H
                                                                   43.7000 LB/H
                                                                           CON IGN TIM/RETARD ENSINE SPARK

                                                          NOX       1.8000 G/HP-H
                                                                   14.2000 LB/H
                                                                           NONE

                                                          NOX      10.0000 G/HP-H
                                                                   11.0000 LB/H
                                                                           AIR/FUEL RATIO CONTROL
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
                                                                                                                             BACT
NOTES
(») INDICATES DATUM WAS TRUNCATED FCR THIS TABLE.

PAGE G- 573
                                                                                                     INITIAL REVIEW  POST STARTUP
                                                                                        REVIEW STATUS:  04/01/1933
                                                      ID  N'trBER  LA-OO^O
                                                                                                           SC'_"CE TYPE CODE   5.16

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE-—         PETROLEUM INDUSTRY — OTHER


COMPANY NAME/SITE LOCATION  TRUNKLINE LNG CO.                                         LAKE  CHARLES,  LA
                                                                                                                  CALCASIEU PARISH


DETERMINATION IS EACT FOR A NEW SOURCE.                                                        DATE  OF PERMIT ISSUANCE—   04/25/83
PERMIT NO. PSD-LA-97,M-1                                                                       ESTIMATED  DATE OF  START-UP—
DETERMINATION MADE BY       LAQD/EPA REGION VI             BHARAT CONTRACTOR                   (5041-342-8940
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT    EMISSION LIMITS                                   ...  * B4SIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT  OR  PROCESS  MODIFICATION   ...  PCT  EFF


TURBINE, GAS, 2                     105.00 MMBTU/H
                                                           NOX       79.0000  LB/H                                             N/A
                                                                            CCMB.  CONTRL, 02 & CO MONITOR
VAPORIZER, LNG, 7 EA                 72.54 NMBTU/H
                                                           NOX        3.6600  LB/H                                             N/A
                                                                            COMBUSTION CONTROL
HEATER, FUEL GAS, 2 EA                3.50 MMBTU/H
                                                           NOX        0.6300  LB/H                                             N/A


NOTES -	--
THE ORIGINAL PERMIT, PSD-LA-97, WAS ISSUED ON 02/09/79 BASED ON 75.  PPM NOX  EMISSION LIMITS UNDER NSPS. HOWEVER,  THE NSPS AMME
NDED CM 01/27/82, SPECIFICALLY EXEMPTED THESE TURBINES FROM H20 INJECTION CONTROLS.










                                                                                                      INITIAL  WIEW  POST  STARTUP
<*> INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.                                        REVIEW STATUS:

PAGE G- 574                                           ID NUMBER LA-0047                                   SOURCE  TYPE CODE   5.16

-------
                                             APPENDIX —  DETAILED  SOURCE LISTING
                                                                                                                        05/22/1984



SOURCE TYPE/SIZE—         PETROLEUM INDUSTRY — OTHER


COMPANY NAME/SITE LOCATION  UNITED GAS PIPE LINE CO.                                        HOUSTON,  LA 77001
                            P.O. BOX 1478


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                    DATE  OF PERMIT ISSUANCE—  03/04/80
PERMIT NO. (REGION FILE NO.) PSD-LA-230                                                        ESTIMATED DATE OF START-UP-
DETERMINATION MADE BY       EPA REGION VI                  JOHN BUNYAK                         (214)-767-1594
                             (AGENCY)                   (AGENCY CONTACT PERSON)                    (PHONE)



PROCESSES SUBJECT                     THROUGHPUT        POLLUTANT     EMISSION LIMITS                                   ... & BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS MODIFICATION  ... PCT ErF
— •"• — ———•————•-— — —-*— — «• — — —  • — — — — _ — — —<——•——— — —•— —.—.«.— ____»,_»_-. — »____—,_.w.___—,„_.„__ _,, _ 1M««»— »...— W _ .«_.._._ _«.____w_._ _ _ _——._•.__-.___•• ..____.».__..,_,.__.>__ ..

COMPRESSOR ENGINE, 3 EA            3500.00 HP
                                                           NOX     107.9000 LB/H EA                                          BACT
                                                                    30.8000 LB/MHP-H
                                                                            CON. AIR/FUEL RATIO,  IGN. TIM.


NOTES 	
(«) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 575
             INITIAL REVIEW  POST STARTUP
REVIEM STATUS;  0^/01/1933
                                                      ID  NUMBER  LA-0039
                                                                                                           SC'JRCE TYPE CODE   5.16

-------
                                             APPENDIX — DETAILED SOURCE LISTING
                                                                                                                        05/22/1984



SOIRCE TYPE/SIZE---         PETROLEUM INDUSTRY — OTHER


COMPANY NAME/SITE LOCATION  UNITED PIPE LINE CO.                                            HOUSTON,  TX 77001
                            P.O. BOX 1478


DETERMINATION IS BACT FOR A MODIFIED SOURCE.                                                   DATE  OF PERMIT ISSUANCE--  03/04/60
PERMIT NO. TX-211                                                                              ESTIMATED  DATE OF  START-UP--
DETERMINATION HADE BY       EPA REGION VI                  JOHN BUNYAK                         (214J-767-15S4
                             (AGENCY)                   (AGENCY CONTACT PERSON)                     (PHONE)



PROCESSES SUBJECT                     THROUGHPUT         POLLUTANT    EMISSION LIMITS                                   ...  t BASIS
TO THIS PERMIT                         CAPACITY          EMITTED            CONTROL EQUIPMENT OR  PROCESS  MODIFICATION  ...  PCT EFF


COMPRESSOR ENGINE, 3               1000.00 HP EA
                                                           NOX       31.5000  LB/H                                             BACT
                                                                    31.5000  LB/MHP-H
                                                                            CNTRL AIR/FUEL RATIO,  IGN  TIM.


NOTES 	
(*) INDICATES DATUM WAS TRUNCATED FOR THIS TABLE.

PAGE G- 576
             INITIAL REVIEW  POST STARTUP
REVIEW STATUS;   04/01/1933
                                                      ID  NUMBER  TX-0070
                  SC'JRCE TYPE CODE   5.16

-------