APPENDIX A. PERMIT DESCRIPTIONS
ACCESS »: 73722
PERMIT ID NO; CT-672
AGENCY: WY DEPT. OF ENV. QUALITY, AIR QUALTIY DIV.
PERMITTING CONTACT: BRENDA DAI LEY
STATE: WY NOTABLE: Y
PHONE: (307) 777-7391
FACILITY CATEGORY: CHEMICAL MANUFACTURE: ARSENIC ACID
CONTROL EQUIPMENT: SCRUBBER, DEMISTER LIMITED HOURS OF OPERATION
COMMENTS:
4-DIGIT SIC CODE: 2879
YEAR PERMIT ISSUED: 1986
LAST YEAR AMENDED: 1987
SCC
POLLUTANT NAME
CAS
LIMIT UNIT
SOURCE
3-01-033-99 ARSENIC AND COMPOUNDS AS AS
7440-38-2
0.0008 G/S PROCESS
ACCESS it: 73723
PERMIT ID NO; CT-511
AGENCY: WY DEPT. OF ENV. QUALITY, AIR QUALTIY DIV.
PERMITTING CONTACT: BRENDA DAILEY
STATE: WY NOTABLE: Y
PHONE: (307) 777-7391
FACILITY CATEGORY: CHEMICAL TRANSFER STATION
CONTROL EQUIPMENT: CARBON CANISTERS 99X CONTROL
COMMENTS:
4-DIGIT SIC CODE: 2869
YEAR PERMIT ISSUED: 1983
LAST YEAR AMENDED:
SCC
POLLUTANT NAME
CAS
LIMIT UNIT
SOURCE
3-01-830-01 ACRYLAMIDE
3-01-830-01 ACRYLONITRILE
79-06-1
107-13-1
0.0000 G/S
0.0000 G/S
FUGITIVE & HANDLING
FUGITIVE & HANDLING
ACCESS if: 73724
PERMIT ID NO: CT-517
AGENCY: WY DEPT. OF ENV. QUALITY, AIR QUALTIY DIV.
PERMITTING CONTACT: BRENDA DAILEY
STATE: WY NOTABLE: Y
PHONE: (307) 777-7391
FACILITY CATEGORY: POLYMER PLANT
CONTROL EQUIPMENT: WET SCRUBBER
COMMENTS: NONE
4-DIGIT SIC CODE: 2821
YEAR PERMIT ISSUED: 1983
LAST YEAR AMENDED:
SCC POLLUTANT NAME
3-01-018-22 ACRYLAMIDE
3-01-018-22 ACRYLONITRILE
3-01-018-22 AMMONIA
CAS #
79-06-1
107-13-1
7664-41-7
LIMIT UNIT SOURCE
0.0000 G/S PROCESS AND STORAGE
0.0000 G/S PROCESS AND STORAGE
0.0010 G/2 PROCESS
314
-------
APPENDIX A. PERMIT DESCRIPTIONS
ACCESS it: 73725
AGENCY: GA OEPT. OF NATURAL RESOURCES, AIR PROTECTION BRANCH
PERMITTING CONTACT: JOHN U. MITCHELL
FACILITY CATEGORY: RESIN PRODUCTION
CONTROL EQUIPMENT: CONDENSER
COMMENTS: NONE
PERMIT ID NO; 2819-063-9597
STATE: GA NOTABLE: Y
PHONE: (404) 656-6900
4-DIGIT SIC CODE: 2819
YEAR PERMIT ISSUED: 1987
LAST YEAR AMENDED:
SCC
POLLUTANT NAME
CAS
LIMIT UNIT
SOURCE
XYLENE
1330-20-7
0.6500 LBS/HR SOLV. RECOVERY PROC.
ACCESS «; 73726
PERMIT ID NO; 2834-121-9479
AGENCY: GA DEPT. OF NATURAL RESOURCES, AIR PROTECTION BRANCH
PERMITTING CONTACT: JOHN W. MITCHELL
FACILITY CATEGORY: BULK PHARMACEUTICAL MFG.
CONTROL EQUIPMENT: CONDENSERS
COMMENTS: FIGURES ARE EXPECTED AVERAGE EMISSION RATES WHICH
RESULT IN 24 HOUR CONCENTRATIONS BELOW GEORGIA
GUIDELINES FOR ACCEPTABLE 24 HOUR CONCENTRATIONS.
STATE: GA NOTABLE: Y
PHONE: (404) 656-6900
4-DIGIT SIC CODE: 2834
YEAR PERMIT ISSUED: 1987
LAST YEAR AMENDED:
SCC
POLLUTANT NAME
CAS
LIMIT UNIT
SOURCE
ACETONE
AMMONIA
ETHANOL
ETHYL ACETATE
HEPTANE
METHANOL
TETRAHYDROFURAN
67-64-1 3.0700 LBS/HR PHARMACEUTICAL MFG.
7664-41-7 3.8100 LBS/HR PHARMACEUTICAL MFG.
64-17-5 5.8700 LBS/HR PHARMACEUTICAL MFG.
114-78-6 4.4900 LBS/HR PHARMACEUTICAL MFG.
142-82-5 2.3000 LBS/HR PHARMACEUTICAL MFG.
67-56-1 1.8200 LBS/HR PHARMACEUTICAL MFG.
109-99-9 4.6000 LBS/HR PHARMACEUTICAL MFG.
315
-------
APPENDIX A. PERMIT DESCRIPTIONS
ACCESS «; 75729
PERMIT ID NO; 86-A-041A
AGENCY: IQUA DEPT. OF NATURAL RESOURCES
PERMITTING CONTACT: BILL YOUNGQUIST
FACILITY CATEGORY: INDUSTRIAL INORGANIC CHEMICALS
CONTROL EQUIPMENT: SCRUBBER
COMMENTS: PERMIT 86-A-041A AND PERMIT 86-A041 ARE THE SAME
PERMITS, BUT DUE TO NATICH DATABASE RESTRICTIONS
THEY HAVE BEEN IDENTIFIED AS SEPERATE PERMITS.
STATE: IA NOTABLE: Y
PHONE: (515) 281-8924
4-DIGIT SIC CODE: 2810
YEAR PERMIT ISSUED: 1986
LAST YEAR AMENDED:
SCC
POLLUTANT NAME
CAS
LIMIT UNIT
SOURCE
HYDROGEN CHLORIDE
7647-01-0
0.6400 TN/YR TRANSFER STATION
ACCESS if: 73730
PERMIT ID NO; 86-A-041
AGENCY: IOWA DEPT. OF NATURAL RESOURCES
PERMITTING CONTACT: BILL YOUNGQUIST
STATE: IA NOTABLE: Y
PHONE: (515) 281-8924
FACILITY CATEGORY: INDUSTRIAL INORGANIC CHEMICALS
CONTROL EQUIPMENT: SCRUBBER
COMMENTS: PERMIT 86-A-041 AND PERMIT 86-A-041A ARE THE SAME
PERMITS, BUT DUE TO NATICH DATABASE RESTRICTIONS
THEY HAVE BEEN IDENTIFIED AS SEPERATE PERMITS.
4-DIGIT SIC CODE: 2810
YEAR PERMIT ISSUED: 1986
LAST YEAR AMENDED:
SCC
POLLUTANT NAME
CAS
LIMIT UNIT
SOURCE
HYDROGEN CHLORIDE
7647-01-0
0.2700 LBS/HR TRANSFER STATION
ACCESS »; 73731
PERMIT ID NO; 86-A-011
AGENCY: IOWA DEPT. OF NATURAL RESOURCES
PERMITTING CONTACT: BILL YOUNGQUIST
STATE: IA NOTABLE: Y
PHONE: (515) 281-8924
FACILITY CATEGORY: PESTICIDES AND AGRICULTURAL CHEMICALS
CONTROL EQUIPMENT: FABRIC DUST COLLECTOR
COMMENTS: CARBAMATE PESTICIDE BROOT
4-DIGIT SIC CODE: 2879
YEAR PERMIT ISSUED: 1986
LAST YEAR AMENDED:
SCC
POLLUTANT NAME
CAS
LIMIT UNIT
SOURCE
TRIMETHYLPHENYL N-METHYLCARBAMATE
58784-13-7
0.0600 GR/SCF PROCESS
316
-------
APPENDIX A. PERMIT DESCRIPTIONS
ACCESS »; 73732
PERMIT ID NO; 86-A-010
AGENCY: IQUA DEPT. OF NATURAL RESOURCES
PERMITTING CONTACT: BILL YOUNGQUIST
FACILITY CATEGORY: PESTICIDES AND AGRICULTURAL CHEMICALS
CONTROL EQUIPMENT: FABRIC DUST COLLECTOR
COMMENTS: NONE
STATE: IA NOTABLE: Y
PHONE: (515) 281-8924
4-DIGIT SIC CODE: 2879
YEAR PERMIT ISSUED: 1986
LAST YEAR AMENDED:
SCC
POLLUTANT NAME
CAS *
LIMIT UNIT
SOURCE
AMIBEN
133-90-4
0.1000 GR/SCF PROCESS
ACCESS »: 73733
PERMIT ID NO; 85-A-1385A
AGENCY: IOWA DEPT. OF NATURAL RESOURCES
PERMITTING CONTACT: BILL YOUNGQUIST
STATE: IA NOTABLE: Y
PHONE: (515) 281-8924
FACILITY CATEGORY: PESTICIDES AND AGRICULTURAL CHEMICALS
CONTROL EQUIPMENT: AFTERBURER
COMMENTS: PERMIT 85-A-1385 AND PERMIT 85-A-1385A ARE THE
SAME PERMIT. BUT DUE TO NATICH DATABASE RESTRIC-
TIONS THEY HAVE BEEN SEPERATED.
4-DIGIT SIC CODE: 2879
YEAR PERMIT ISSUED: 1985
LAST YEAR AMENDED:
SCC
POLLUTANT NAME
CAS *
LIMIT UNIT
SOURCE
ALACHLOR
15972-60-8 43.8000 LBS/YR PROCESS
ACCESS «: 73743
PERMIT ID NO; NC 2830
AGENCY: PUGET SOUND AIR POLLUTION CONTROL AGENCY
PERMITTING CONTACT: HARRY WATTERS
STATE: WA NOTABLE: Y
PHONE: (206) 344-7334
FACILITY CATEGORY: PIPELINE FOR REFINED PETROLEUM
CONTROL EQUIPMENT:
COMMENTS:
TWO CATALYTIC AFTERBURNERS
GASOLINE AND OTHER PETROLEUM VAPORS FROM A
PIPELINE LEAK VENTED THROUGH 2 CATALYTIC BURNERS.
SOURCE TEST TO DETERMINE COMBUSTION EFFICIENCY.
TEMPERATURE RISE ACROSS CATALYTIC BED MONITORED
AND RECORDED.
4-DIGIT SIC CODE: 4613
YEAR PERMIT ISSUED: 1986
LAST YEAR AMENDED:
SCC
POLLUTANT NAME
CAS it
LIMIT UNIT
SOURCE
BENZENE
GASOLINE
71-43-2
8006-61-9
0.0000
0.0000
317
-------
APPENDIX A. PERMIT DESCRIPTIONS
ACCESS *: 73745
PERMIT ID NO; NC 2797
AGENCY: PUGET SOUND AIR POLLUTION CONTROL AGENCY
PERMITTING CONTACT: HARRY MATTERS
STATE: UA NOTABLE: Y
PHONE: (206) 344-7334
FACILITY CATEGORY: ASPHALT SATURATOR
CONTROL EQUIPMENT:
COMMENTS:
SMOG HOG ESP
CONDITIONS- (DSOURCE TEST (2) TEMPERATURE
MONITORING OF ESP INLET GAS (3) OPACITY LIMIT
BASED ON OPACITY DURING SOURCE TEST. SUBJECT TO
SUBPART UU OF 40 CFR 60.
4-DIGIT SIC CODE: 2952
YEAR PERMIT ISSUED: 1986
LAST YEAR AMENDED:
SCC
POLLUTANT NAME
CAS *
LIMIT UNIT
SOURCE
3-05-001-04 ASPHALT (PETROLEUM) FUMES
8052-42-4
40.0000 G/MG FELT SAT.SPRAY/DIP
ACCESS «; 73747
PERMIT ID NO; NC 2735
AGENCY: PUGET SOUND AIR POLLUTION CONTROL AGENCY
PERMITTING CONTACT: HARRY UATTERS
STATE: UA NOTABLE: Y
PHONE: (206) 344-7334
FACILITY CATEGORY: ASPHALT ROOFING MANUFACTURE
CONTROL EQUIPMENT: HEPA FILTER
COMMENTS: MIXING OF ASBESTOS INTO ASPHALT ROOFING MATERIAL.
4-DIGIT SIC CODE: 2952
YEAR PERMIT ISSUED: 1986
LAST YEAR AMENDED:
ACCESS #: 73748
PERMIT ID NO; NC 2831
AGENCY: PUGET SOUND AIR POLLUTION CONTROL AGENCY
PERMITTING CONTACT: HARRY UATTERS
STATE: UA NOTABLE: Y
PHONE: (206) 344-7334
FACILITY CATEGORY: WOOD PRESERVING
CONTROL EQUIPMENT: VERTICAL TUBE & SHELL CONDENSOR
COMMENTS: TEMPERATURE MONITOR ON CONDENSOR OUTLET.
PSAPCA BOARD RESOLUTION NO. 596. ODOR CONTROL
NO EMISSION LIMIT.
4-DIGIT SIC CODE: 2491
YEAR PERMIT ISSUED: 1986
LAST YEAR AMENDED:
SCC
POLLUTANT NAME
CAS 0
LIMIT UNIT
SOURCE
3-07-005-01 NAPHTHALENE
91-20-3
0.0000
CREOSOTE UD PRES.TRT
318
-------
APPENDIX A. PERMIT DESCRIPTIONS
ACCESS »; 73749
PERMIT ID NO; NC 2748
AGENCY: PUGET SOUND AIR POLLUTION CONTROL AGENCY
PERMITTING CONTACT: HARRY WAITERS
FACILITY CATEGORY: WOOD PRESERVING
CONTROL EQUIPMENT:
COMMENTS!
VERTICAL TUBE & SHELL CONDENSOR
TEMPERATURE MONITOR ON CONDENSOR OUTLET;
PSAPCA BOARD RESOLUTION NO. 596. ODOR CONTROL.
NO EMISSION LIMIT.
STATE: UA NOTABLE: Y
PHONE: (206) 344-7334
4-DIGIT SIC CODE: 2491
YEAR PERMIT ISSUED: 1986
LAST YEAR AMENDED:
SCC
POLLUTANT NAME
CAS »..
LIMIT UNIT
SOURCE
3-07-005-01 NAPHTHALENE
91-20-3
0.0000
CREOSOTE UD PRES.TRT
ACCESS »; 73751
PERMIT ID NO; NC 2854
AGENCY: PUGET SOUND AIR POLLUTION CONTROL AGENCY
PERMITTING CONTACT: HARRY UATTERS
STATE: UA NOTABLE: Y
PHONE: (206) 344-7334
FACILITY CATEGORY: SEMICONDUCTOR MANUFACTURE
CONTROL EQUIPMENT: HARRINGTON PACKED TOWER SCRUBBER,
TRI-MER PACKED TOWER SCRUBBER
COMMENTS: CONTROL BY TECHNOLOGY, NOT EMISSION LIMITS.
EMERGENCY RESPONSE PLAN IN FILE.
4-DIGIT SIC CODE: 3674
YEAR PERMIT ISSUED: 1987
LAST YEAR AMENDED:
SCC
POLLUTANT NAME
CAS if
LIMIT UNIT
SOURCE
3-04-020-99 AMMONIA
3-04-020-99 ARSINE
3-04-020-99 CHLORINE
3-04-020-99 HYDRAZINE
3-04-020-99 HYDROGEN CHLORIDE
3-04-020-99 HYDROGEN FLUORIDE
7664-41-7
7784-42-1
7782-50-5
302-01-2
7647-01-0
7664-39-3
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
ELECTRONIC MANUFAC.
ELECTRONIC MANUFAC.
ELECTRONIC MANUFAC.
ELECTRONIC MANUFAC.
ELECTRONIC MANUFAC.
ELECTRONIC MANUFAC.
319
-------
APPENDIX A. PERMIT DESCRIPTIONS
ACCESS «: 73752
PERMIT ID NO; NC 2767
AGENCY: PUGET SOUND AIR POLLUTION CONTROL AGENCY
PERMITTING CONTACT: HARRY WAITERS
STATE: UA NOTABLE: Y
PHONE: (206) 344-7334
FACILITY CATEGORY: PORTLAND CEMENT PLANT
CONTROL EQUIPMENT:
COMMENTS:
A LIMITS OF POLLUTANTS UILL BE BASED ON SOURCE
TEST TO BE CONDUCTED IN APRIL, 1987. TIRE
DERIVED FUEL (TDF) TO BE BURNT IN CEMENT KILN.
4-DIGIT SIC CODE: 3241
YEAR PERMIT ISSUED: 1986
LAST YEAR AMENDED: 1987
SCC POLLUTANT NAME
3-05-006-06 BENZO(A)PYRENE
3-05-006-06 CADMIUM
3-05-006-06 CHROMIUM
3-05-006-06 COPPER
3-05-006-06 ZINC
CAS *
50-32-8
7440-43-9
7440-47-3
7440-50-8
7440-66-6
LIMIT UNIT
0.0000
0.0000
0.0000
0.0000
0.0000
SOURCE
KILN
KILN
KILN
KILN
KILN
ACCESS it: 73763
PERMIT ID NO; NC2830
AGENCY: PUGET SOUND AIR POLLUTION CONTROL AGENCY
PERMITTING CONTACT: HARRY UATTERS
FACILITY CATEGORY: PIPELINE FOR REFINED PETROLEUM
CONTROL EQUIPMENT: TWO CATALYTIC AFTERBURNERS
COMMENTS: GASOLINE AND OTHER PETROLEUM VAPORS FROM A
PIPELINE LEAK VENTED THROUGH 2 CATALYTIC BURNERS.
SOURCE TEST TO DETERMINE COMBUSTION EFFICIENCY.
TEMPERATURE RISE ACROSS CATALYTIC BED MONITORED
AND RECORDED.
STATE: UA NOTABLE: Y
PHONE: (206) 344-7334
4-OIGIT SIC CODE: 4613
YEAR PERMIT ISSUED: 1986
LAST YEAR AMENDED:
SCC
POLLUTANT NAME
CAS
LIMIT UNIT
SOURCE
BENZENE
GASOLINE
71-43-2
8006-61-9
0.0000
0.0000
320
-------
APPENDIX A. PERMIT DESCRIPTIONS
ACCESS it: 73765
AGENCY: PUGET SOUND AIR POLLUTION CONTROL AGENCY
PERMITTING CONTACT: HARRY UATTERS
FACILITY CATEGORY: ASPHALT SATURATOR
CONTROL EQUIPMENT: SMOG HOG ESP
COMMENTS: CONDITIONS- (1) SOURCE TESTING, (2) TEMPERATURE
MONITORING OF ESP INLET GAS, (3) OPACITY LIMIT
BASED ON OPACITY DURING SOURCE TEST. SUBJECT TO
SUBPART UU OF 40 CFR 60.
PERMIT ID NO; NC2797
STATE: UA NOTABLE: Y
PHONE: (206) 344-7334
4-DIGIT SIC CODE: 2952
YEAR PERMIT ISSUED: 1986
LAST YEAR AMENDED:
SCC
POLLUTANT NAME
CAS
LIMIT UNIT
SOURCE
TRICHLOROETHANE.1,1,1-
3-05-001-04 ASPHALT (PETROLEUM) FUMES
71-55-6 0.0000
8052-42-4 40.0000 G/MG FELT SATURAT.SPR/DIP
ACCESS »; 73767
PERMIT ID NO; NC2735
AGENCY: PUGET SOUND AIR POLLUTION CONTROL AGENCY
PERMITTING CONTACT: HARRY WATTERS
FACILITY CATEGORY: ASPHALT ROOFING MANUFACTURE
CONTROL EQUIPMENT: HEPA FILTER
STATE: WA NOTABLE: Y
PHONE: (206) 344-7334
4-DIGIT SIC CODE: 2952
YEAR PERMIT ISSUED: 1986
LAST YEAR AMENDED:
COMMENTS: MIXING OF ASBESTOS INTO ASPHALT ROOFING MATERIAL.
SCC POLLUTANT NAME CAS » LIMIT UNIT
SOURCE
3-05-001-98 OLIVINE
1317-71-1
0.0000
ASPHALT ROOF.MATER.
ACCESS »: 73768
PERMIT ID NO; NC2831
AGENCY: PUGET SOUND AIR POLLUTION CONTROL AGENCY
PERMITTING CONTACT: HARRY WATTERS
STATE: UA NOTABLE: Y
PHONE: (206) 344-7334
FACILITY CATEGORY: WOOD PRESERVING
CONTROL EQUIPMENT: VERTICAL TUBE AND SHELL CONDENSOR
COMMENTS: TEMPERATURE MONITOR ON CONDENSOR OUTLET;
PSAPCA BOARD RESOLUTION NO. 596
4-DIGIT SIC CODE: 2491
YEAR PERMIT ISSUED: 1986
LAST YEAR AMENDED:
SCC
POLLUTANT NAME
CAS #
LIMIT UNIT
SOURCE
3-07-005-01 NAPHTHALENE
91-20-3
0.0000
CREOSOTE WD.PRES.TRT
321
-------
APPENDIX A. PERMIT DESCRIPTIONS
ACCESS »; 73769
PERMIT ID NO: NC2748
AGENCY: PUGET SOUND AIR POLLUTION CONTROL AGENCY
PERMITTING CONTACT: HARRY UATTERS
FACILITY CATEGORY: WOOD PRESERVING
CONTROL EQUIPMENT: VERTICAL TUBE AND SHELL CONDENSOR
COMMENTS: TEMPERATURE MONITOR ON CONDENSOR OUTLET;
PSAPCA BOARD RESOLUTION NO. 596
STATE: WA NOTABLE: Y
PHONE: (206) 344-7334
4-DIGIT SIC CODE: 2491
YEAR PERMIT ISSUED: 1986
LAST YEAR AMENDED:
SCC
POLLUTANT NAME
CAS #
LIMIT UNIT
SOURCE
3-07-005-01 NAPHTHALENE
91-20-3
0.0000
CREOSOTE WD.PRES.TRT
ACCESS »; 73771
PERMIT ID NO; NC2854
AGENCY: PUGET SOUND AIR POLLUTION CONTROL AGENCY
PERMITTING CONTACT: HARRY UATTERS
STATE: WA NOTABLE: Y
PHONE: (206) 344-7334
FACILITY CATEGORY: SEMICONDUCTOR MANUFACTURE 4-DIGIT SIC CODE: 3674
YEAR PERMIT ISSUED: 1987
CONTROL EQUIPMENT: HARRINGTON PACKED TOWER SCRUBBER, TRI-MER PACKED LAST YEAR AMENDED:
TOWER SCRUBBER
COMMENTS: EMERGENCY RESPONSE PLAN IN FILE.
SCC POLLUTANT NAME
ARSINE
CHLORINE
HYDRAZINE
HYDROGEN CHLORIDE
HYDROGEN FLUORIDE
PHOSPHINE
SI LANE
3-04-020-99 AMMONIA
CAS #
7784-42-1
7782-50-5
302-01-2
7647-01-0
7664-39-3
7803-51-2
7803-62-5
7664-41-7
LIMIT UNIT SOURCE
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
322
-------
APPENDIX A. PERMIT DESCRIPTIONS
ACCESS »: 73772
AGENCY: PUGET SOUND AIR POLLUTION CONTROL AGENCY
PERMITTING CONTACT: HARRY WATTERS
FACILITY CATEGORY: PORTLAND CEMENT PLANT
CONTROL EQUIPMENT:
COMMENTS: A LIMITS OF POLLUTANTS WILL BE BASED ON SOURCE
TESTS TO BE CONDUCTED IN APRIL 1987. TIRE
DERIVED FUEL (TDF) TO BE BURNED IN CEMENT KILN.
PERMIT ID NO; NC2767
STATE: WA NOTABLE: Y
PHONE: (206) 344-7334
4-DIGIT SIC CODE: 3241
YEAR PERMIT ISSUED: 1986
LAST YEAR AMENDED: 1987
sec
3-05-006-06
POLLUTANT NAME
CADMIUM
CHROMIUM
COPPER
LEAD POUDER
ZINC
BENZO(A)PYRENE
CAS *
7440-43-9
7440-47-3
7440-50-8
7439-92-1
7440-66-6
50-32-8
LIMIT UNIT
0.0000 TBD
0.0000 TBD
0.0000 TBD
0.0000 TBD
0.0000 TBD
0.0000 TBD
SOURCE
KILN
ACCESS 0; 73807
PERMIT ID NO; 2879-092-9419
AGENCY: GA DEPT. OF NATURAL RESOURCES, AIR PROTECTION BRANCH
PERMITTING CONTACT: JOHN U. MITCHELL
FACILITY CATEGORY: CCA MIX PLANT
CONTROL EQUIPMENT: VENTURI SCRUBBER
COMMENTS: 10 FOOT STACK, 24 HR/DAY
10 FOOT STACK, 24 HR/DAY
SCC
POLLUTANT NAME
CAS #
STATE: GA NOTABLE: Y
PHONE: (404) 656-6900
4-DIGIT SIC CODE: 2879
YEAR PERMIT ISSUED: 1986
LAST YEAR AMENDED:
LIMIT UNIT
SOURCE
ARSENIC AND COMPOUNDS AS AS
CHROMATE. (CR042-)
COPPER OXIDE, (CUO)
7440-38-2 0.2300 GMS/HR CCA MIX TANK
13907-45-4 0.0200 GMS/HR CCA MIX TANK
1317-38-0 10.0000 GMS/HR CCA MIX TANK
323
-------
APPENDIX A. PERMIT DESCRIPTIONS
ACCESS »; 73808
PERMIT ID NO: 2819-063-9435
AGENCY: GA DEPT. OF NATURAL RESOURCES, AIR PROTECTION BRANCH
PERMITTING CONTACT: JOHN U. MITCHELL
STATE: GA NOTABLE: Y
PHONE: (404) 656-6900
FACILITY CATEGORY: CHEMICAL PROCESSING
CONTROL EQUIPMENT: SCRUBBERS AND CARBON ABSORBENT DRUMS
COMMENTS: MBAPA - METHYL-BIS(3-AMINOPROPYL)AMINE
MBAPA - METHYL-BIS(3-AMINOPROPYL)AMINE
4-DIGIT SIC CODE: 2819
YEAR PERMIT ISSUED: 1986
LAST YEAR AMENDED:
SCC POLLUTANT NAME
ACRYLONITRILE
MONOMETHYLAMINE
AMMONIA
PROPYLAMINE
CAS #
107-13-1
74-89-5
7664-41-7
107-10-8
LIMIT UNIT SOURCE
0.0000 NO/DCT STORAGE/MBAPA PROCES
0.0000 NC/DCT MBAPA PROCESS
145.0000 GMS/HR MBAPA PROCESS
40.0000 GMS/HR MBAPA PROCESS
ACCESS it: 98973
PERMIT ID NO; 7775-7776
AGENCY: SACRAMENTO CO. AIR POLLUTION CONTROL DISTRICT
PERMITTING CONTACT: ERIC SKELTON
STATE: CA NOTABLE: Y
PHONE: (916) 366-2107
FACILITY CATEGORY: GRAPHITE FIBRE MANUFACTURING
CONTROL EQUIPMENT: FUME INCINERATORN
COMMENTS: NONE
4-DIGIT SIC CODE: 2824
YEAR PERMIT ISSUED: 1985
LAST YEAR AMENDED:
SCC
POLLUTANT NAME
CAS #
LIMIT UNIT
SOURCE
3-01-999-99 HYDROGEN CYANIDE
74-90-8
100.0000 PPM PROCESS
ACCESS #: 98975
PERMIT ID NO; 8354
AGENCY: SACRAMENTO CO. AIR POLLUTION CONTROL DISTRICT
PERMITTING CONTACT: ERIC SKELTON
STATE: CA NOTABLE: Y
PHONE: (916) 366-2107
FACILITY CATEGORY: SOIL CLEANUP
(COMMERCIAL POLLUTION)
CONTROL EQUIPMENT: PROCESS RATE
COMMENTS: SOIL IS AERATED AND POLLUTANTS ARE VENTED TO THE
ATMOSPHERE GASOLINE CONTAMINATED SOIL.
NOTE: THIS PERMIT HAS BEEN CANCELLED.
4-DIGIT SIC CODE: 4959
YEAR PERMIT ISSUED: 1986
LAST YEAR AMENDED:
SCC
POLLUTANT NAME
CAS #
LIMIT UNIT
SOURCE
BENZENE
71-43-2
2.0000 LB/DAY PROCESS
324
-------
APPENDIX A. PERMIT DESCRIPTIONS
ACCESS »; 98981
AGENCY: SACRAMENTO CO. AIR POLLUTION CONTROL DISTRICT
PERMITTING CONTACT: ERIC SKELTON
FACILITY CATEGORY: CHEMICAL MFG.
(AEROSPACE AND MILITARY PRODUCTS)
CONTROL EQUIPMENT:
COMMENTS: EMISSION LIMIT: NON DETECTABLE
EMISSION LIMIT: NON DETECTABLE
PERMIT ID MO; 6311.6312.6313
STATE: CA NOTABLE: Y
PHONE: (916) 366-2107
4-DIGIT SIC CODE: 2869
YEAR PERMIT ISSUED: 1980
LAST YEAR AMENDED:
SCC
POLLUTANT NAME
CAS *
LIMIT UNIT
SOURCE
3-01-999-99 ETHYLENEIMINE
3-01-999-99 PHOSGENE
151-56-4
75-44-5
0.0000
0.0000
ACCESS It: 98982
PERMIT ID NO; 7677-7681
AGENCY: SACRAMENTO CO. AIR POLLUTION CONTROL DISTRICT
PERMITTING CONTACT: ERIC SKELTON
STATE: CA NOTABLE: Y
PHONE: (916) 366-2107
FACILITY CATEGORY: CHEMICAL MFG.
(AEROSPACE AND MILITARY PRODUCTS)
CONTROL EQUIPMENT: CONDENSERS,PACKED COLUMN SCRUBBERS.TEMPERTURE
CARBON ADSORBER
COMMENTS:
4-DIGIT SIC CODE: 2869
YEAR PERMIT ISSUED: 1984
LAST YEAR AMENDED: 1985
SCC
POLLUTANT NAME
CAS
LIMIT UNIT
SOURCE
3-01-999-99 ETHYLENE DICHLORIDE
107-06-2
22.0000 LB/DAY PROCESS
ACCESS #: 98983
PERMIT ID NO; 7511.7517.7547.7889
AGENCY: SACRAMENTO CO. AIR POLLUTION CONTROL DISTRICT
PERMITTING CONTACT: ERIC SKELTON
STATE: CA NOTABLE: Y
PHONE: (916) 366-2107
FACILITY CATEGORY: CHEMICAL MANUFACTURING
(AEROSPACE AND MILITARY PRODUCTS)
CONTROL EQUIPMENT: CONDENSERS,PACKED COLUMN SCRUBBERS,TEMPERATURE,
CARBON ADSORBER
COMMENTS:
4-DIGIT SIC CODE: 2869
YEAR PERMIT ISSUED: 1982
LAST YEAR AMENDED: 1984
SCC
POLLUTANT NAME
CAS #
LIMIT UNIT
SOURCE
3-01-999-99 CHLOROFORM
67-66-3
21.0000 LB/DAY PROCESS
325
-------
APPENDIX A. PERMIT DESCRIPTIONS
ACCESS *: 98984
PERMIT ID NO; 7204.7219.7220.7226
AGENCY: SACRAMENTO CO. AIR POLLUTION CONTROL DISTRICT
PERMITTING CONTACT: ERIC SKELTON
FACILITY CATEGORY: CHEMICAL MANUFACTURING
(AEROSPACE AND MILITARY PRODUCTS)
CONTROL EQUIPMENT: CONDENSERS
COMMENTS:
STATE: CA NOTABLE: Y
PHONE: (916) 366-2107
4-DIGIT SIC CODE: 2869
YEAR PERMIT ISSUED: 1982
LAST YEAR AMENDED: 1985
SCC
POLLUTANT NAME
CAS
LIMIT UNIT
SOURCE
3-01-999-99 TOLUENE
108-88-3
11.4000 LB/DAY PROCESS
ACCESS #; 99893
PERMIT ID NO; 82-A-103
AGENCY: IOWA OEPT. OF NATURAL RESOURCES
PERMITTING CONTACT: BILL YOUNGQUIST
FACILITY CATEGORY: PLASTIC BOTTLE BLOW MOLDING
CONTROL EQUIPMENT: PACKED BED SCRUBBER NAOH
COMMENTS:
STATE: IA NOTABLE: Y
PHONE: (515) 281-8924
4-DIGIT SIC CODE: 3079
YEAR PERMIT ISSUED: 1982
LAST YEAR AMENDED:
SCC
POLLUTANT NAME
CAS
LIMIT UNIT
SOURCE
FLUORIDES
16984-48-8
2.5000 HG/M3 PROCESS
326
-------
APPENDIX B
SOURCE TEST DESCRIPTIONS
Appendix B provides a complete description of each source test listed in
Tables 24 and 25 in Section 11. Source tests are described in consecutive
order by access number. Each description contains information on agency name,
source testing contact and phone number, test ID number, facility category,
SIC Code, test date, sampling technique and analytical method. Source
Classification Codes (SCC), pollutant names, CAS numbers, emission rates,
location of measurement, and comments. Note that a measured emission rate of
0.0000 may not necessarily mean 0. It may mean that the rate was not
submitted or that the concentration is less than 0.0001 (1/10,000).
327
-------
APPENDIX B. SOURCE TEST DESCRIPTIONS
ACCESS «t 73658
TEST ID NO; C-85-022-A
AGENCY: CA AIR RESOURCES BOARD
TEST CONTACT: DEAN SIMEROTH
STATE: CA NOTABLE: Y
PHONE: (916) 445-0657
FACILITY CATEGORY: GLASS FURANCE
SAMPLING TECHNIQUE: METHOD 5
ANALYTICAL METHOD: DIPHENYLCARBAZIDE COLORIMETRY
COMMENTS: AVERAGE OF THREE TESTS
4-DIGXT SIC CODE: 3221
TEST DATE: 05/23/85
SCC
POLLUTANT NAME
CAS *
RATE UNIT
LOCATION
3-05-014 CHROMIUM
7440-47-3
0.0007 LB/HR STACK
ACCESS «; 73659
TEST ID NO; C-85-022
AGENCY: CA AIR RESOURCES BOARD
TEST CONTACT: DEAN SIMEROTH
STATE: CA NOTABLE: Y
PHONE: (916) 445-0657
FACILITY CATEGORY: GLASS FURANCE
SAMPLING TECHNIQUE: METHOD 5
ANALYTICAL METHOD: DIPHENYLCARBAZIDE COLORIMETRY
COMMENTS: AVERAGE OF THREE TESTS
4-DIGIT SIC CODE: 3221
TEST DATE: 05/20/85
SCC
POLLUTANT NAME
CAS
RATE UNIT
LOCATION
3-05-014 CHROMIUM
7440-47-3
0.0001 LB/HR STACK
ACCESS »; 73660
TEST ID NO; ARB/SS-87-11
AGENCY: CA AIR RESOURCES BOARD
TEST CONTACT: DEAN SIMEROTH
STATE: CA NOTABLE: Y
PHONE: (916) 445-0657
FACILITY CATEGORY: HOSPITAL REFUSE INCINERATOR
SAMPLING TECHNIQUE: MM-5. GRAB BAG SAMPLES
ANALYTICAL METHOD: GC/MS. GC/FID/ECD
COMMENTS:
4-DIGIT SIC CODE: 8062
TEST DATE: 10/28/86
SCC
POLLUTANT NAME
CAS f
RATE UNIT
LOCATION
CARBON TETRACHLORIDE
DIOXINS
TETRACHLOROETHYLENE
TRICHLOROETHYLENE
5-02-005 VOLATILE ORGANIC COMPOUNDS
56-23-5 6.6000 UG/SEC BAGHOUSE VENT
CL-DIOXIN 165.0000 NG/SEC BAGHOUSE VENT
127-18-4 7.0000 UG/SEC BAGHOUSE VENT
79-01-6 1.5000 UG/SEC BAGHOUSE VENT
CL-VOC 2.8000 UG/SEC BAGHOUSE VENT
328
-------
APPENDIX B. SOURCE TEST DESCRIPTIONS
ACCESS »; 73661
TEST ID NO: ARB/SS-87-01
AGENCY: CA AIR RESOURCES BOARD
TEST CONTACT: DEAN SIMEROTH
STATE: CA NOTABLE: Y
PHONE: (916) 145-0657
FACILITY CATEGORY: HOSPITAL REFUSE INCINERATOR
SAMPLING TECHNIQUE: MODIFIED METHOD 5CSEMI VOLATILE ORGANIC)
ANALYTICAL METHOD: GC/NS (SEMI VOLATILE ORGANICS) (SEE COMMENTS)
COMMENTS: SAMPLING TECHNIQUES FOR VOLATILE ORGAICS: GRAB
WITH BAG.
ANALYTICAL METHOD FOR VOLATILE ORGANICS: GC/FID
AND GC/ECD.
4-DIGIT SIC CODE: 8062
TEST DATE: 08/11/86
SCC
POLLUTANT NAME
CAS if
RATE
UNIT
LOCATION
5-02-005
OIOXINS
BENZENE
TOLUENE
VOLATILE ORGANIC COMPOUNDS
CL-DIOXIN 618.0000 NG/SEC EXHAUST STACK
71-43-2 0.4100 LB/HR EXHAUST STACK
108-88-3 0.0001 LB/HR EXHAUST STACK
CL-VOC 0.0000 LB.HR EXHAUST STACK
ACCESS 0; 73662
TEST ID NO; ARB/SS-87-08
AGENCY: CA AIR RESOURCES BOARD
TEST CONTACT: DEAN SIMEROTH
STATE: CA NOTABLE: Y
PHONE: (916) 445-0657
FACILITY CATEGORY:
SAMPLING TECHNIQUE:
ANALYTICAL METHOD:
COMMENTS:
EMISSIONS FORM 1C. ENGINE FUELED WITH GASES FORM
A SANITARY LANDFILL.
MODIFIED METHOD 5 (SEMI-VOLATILE ORGANIC)
GC/MS (SEMI-VOLATILE ORGANIC) (SEE COMMENTS)
SAMPLING TECHNIQUE FOR VOLATILE ORGANICS: GRAB
WITH BAG.
ANALYTICAL METHOD FOR VOLATILE ORGANICS: GC/FID
AMD GC/ECD.
NO DETECTED EMISSIONS RATE FOR DIOXINS/FURAN.
4-DIGIT SIC CODE: 3519
TEST DATE: 01/28/86
SCC
5-03-006
POLLUTANT NAME
BENZENE
CARBON TETRACHLORIDE
DIOXINS
TOLUENE
TRICHLOROETHANE.1,1,1-
VINYL CHLORIDE
CAS #
71-43-2
56-23-5
CL-DIOXIN
108-88-3
71-55-6
75-01-4
RATE UNIT
0.0190 LB/HR
0.0000 LB/HR
0.0000 LB/HR
0.0049 LB/HR
0.0000 LB/HR
0.0001 LB/HR
LOCATION
CATALYTIC CONVERTER
CATALYTIC CONVERTER
CATALYTIC CONVERTER
CATALYTIC CONVERTER
CATALYTIC CONVERTER
CATALYTIC CONVERTER
329
-------
APPENDIX B. SOURCE TEST DESCRIPTIONS
ACCESS #; 73663
TEST ID NO; ARB/SS-87-06
AGENCY: CA AIR RESOURCES BOARD
TEST CONTACT: DEAN SINEROTH
STATE: CA NOTABLE: Y
PHONE: (916) 445-0657
FACILITY CATEGORY;
EMISSIONS FROM FLARE USED FOR COMBUSTION OF GASES
FROM A SANITARY LANDFILL
SAMPLING TECHNIQUE
ANALYTICAL METHOD
MODIFIED METHOD 5(SEMI VOLATILE ORGANICS)
GC/MS (SEMI VOLATILE ORGANICS) (SEE COMMENTS)
COMMENTS: SAMPLING TECHNIQUE FOR VOLATILE ORGANICS: GRAB
WITH BAG.
ANALYTICAL METHOD FOR VOLATILE ORGANICS: GC/FID
AND GC/ECD.
NO MEASURED EMISSION RATES DETECTED FOR
FURANS/DIOXIN.
4-DIGIT SIC CODE: 4953
TEST DATE: 02/18/86
sec
POLLUTANT NAME
BENZENE
CARBON TETRACHLORIDE
DIOXINS
TOLUENE
TRICHLOROETHANE, 1,1.1 -
VINYL CHLORIDE
CAS #
71-43-2
56-23-5
CL-DIOXIN
108-88-3
71-55-6
75-01-4
RATE UNIT
0.0004 LB/HR
0.0000 LB/HR
0.0000 LB/HR
0.0024 LB/HR
0.0039 LB/HR
0.0017 LB/HR
LOCATION
FLARE EXHAUST STACK
FLARE EXHAUST STACK
FLARE EXHAUST STACK
FLARE EXHAUST STACK
FLARE EXHAUST STACK
FLARE EXHAUST STACK
ACCESS #: 73664
TEST ID NO; ARB/SS-87-07
AGENCY: CA AIR RESOURCES BOARD
TEST CONTACT: DEAN SIMEROTH
FACILITY CATEGORY: EMISSION FROM GAS TURBINE FUELED WITH GASES FROM
SANITARY LANDFILL
SAMPLING TECHNIQUE: MODIFIED METHOD 5 (SEMI VOLATILE ORGANICS)
ANALYTICAL METHOD: GC/MS (SEMI VOLATILE ORGANICS) (SEE COMMENTS)
COMMENTS: SAMPLING TECHNIQUES FOR VOLATILE ORGANICS: GRAB
WITH BAG.
ANALYTICAL METHODS FOR VOLATILE ORGANICS: GC/FIO,
GC/ECD.
NO EMISSION RATES DETECTED FOR DIOXINS/FURANS.
STATE: CA NOTABLE: Y
PHONE: (916) 445-0657
4-DIGIT SIC CODE: 4953
TEST DATE: 02/01/86
sec
5-03-006
POLLUTANT NAME
BENZENE
DIOXINS
TOLUENE
TRICHLOROETHANE, 1.1,1 •
VINYL CHLORIDE
CAS *
71-43-2
CL-DIOXIN
108-88-3
71-55-6
75-01-4
RATE UNIT LOCATION
0.0279 LB/HR EXHAUST STACK
0.0000 LB/HR EXHAUST STACK
0.1980 LB/HR EXHAUST STACK
0.0057 LB/HR EXHAUST STACK
0.0157 LB/HR EXHAUST STACK
330
-------
APPENDIX B. SOURCE TEST DESCRIPTIONS
ACCESS »; 73665
TEST ID NO; AR8/SS/87-09
AGENCY: CA AIR RESOURCES BOARD
TEST CONTACT: DEAN SIMEROTH
STATE: CA NOTABLE: Y
PHONE: (916) 445-0657
FACILITY CATEGORY: EMISSIONS FROM FLARE USED FOR COMBUSTION OF GASES 4-DIGIT SIC CODE: 4953
FROM SANITARY.
TEST DATE: 07/01/86
SAMPLING TECHNIQUE: MODIFIED METHOD 5 (SEMI-VOLATILE ORGANICS)
ANALYTICAL METHOD: GC/MS (SEMI-VOLATILE ORGANICS)_(SEE COMMENT)
COMMENTS: SAMPLING TECHNIQUE FOR VOLATILE ORGANICS: GRAB
WITH BAG.
ANALYTICAL METHODS FOR VOLATILE ORGANICS: GC/FID
AND GC/ECD.
FOR CHLOROETHENE(VINYL CHLORIDE) NO EMISSION
RATES DETECTED.
see
POLLUTANT NAME
CAS 0
RATE UNIT
LOCATION
4-90-900
CARBON TETRACHLORIDE
DIOXINS
TOLUENE
TRICHLOROETHANE, 1,1,1-
VINYL CHLORIDE
BENZENE
56-23-5
CL-DIOXIN
108-88-3
71-55-6
75-01-4
71-43-2
0.0000 LB/HR
0.0000 LB/HR
0.0009 LB/HR
0.0001 LB/HR
0.0040 LB/HR
0.0028 LB/HR
FLARE EXHAUST 'STACK
FLARE EXHUAST STACK
FLARE EXHAUST STACK
FLARE EXHAUST STACK
FLARE EXHUAST STACK
FLARE EXHAUST STACK
ACCESS #: 73666
TEST ID NO; C-84-004
AGENCY: CA AIR RESOURCES BOARD
TEST CONTACT: DEAN SIMEROTH
STATE: CA NOTABLE: Y
PHONE: (916) 445-0657
FACILITY CATEGORY: USE OF CIRCULATING BED COMBUSTOR TO DESTROY OR 4-DIGIT SIC CODE: 3822
REMOVE ORGANIC COMPOUNDS.
TEST DATE: 05/01/84
SAMPLING TECHNIQUE: MODIFIED METHOD 5 GLASS WOOL WAS USED FOR FILTER.
ANALYTICAL METHOD: GC/FID/ECD
COMMENTS: DETERMINE DESTRUCTION AND REMOVAL EFFICIENCY OF
SYNTHETIC WASTE.
SCC POLLUTANT
ETHYL BENZENE
HEXACHLOROBENZENE
TOLUENE
TRICHLOROBENZENE,
VOLATILE ORGANIC
XYLENE
NAME
1,2,4-
COMPOUNDS
CAS #
100-41-4
118-74-1
108-88-3
120-82-1
CL-VOC
1330-20-7
RATE
99,
99.
97.
99,
99,
99.
.9900
.9900
.3900
.9900
.9900
.9900
UNIT
XDRE
XDRE
XDRE
XDRE
XDRE
XDRE
LOCATION
SAMPLE
SAMPLE
SAMPLE
SAMPLE
SAMPLE
SAMPLE
PORT
PORT
PORT
PORT
PORT
PORT
ON
ON
ON
ON
ON
ON
STACK
STACK
STACK
STACK
STACK
STACK
331
-------
APPENDIX B. SOURCE TEST DESCRIPTIONS
ACCESS 0: 73667
TEST ID NO; C-83-034
AGENCY: CA AIR RESOURCES BOARD
TEST CONTACT: DEAN SIMEROTH
STATE: CA NOTABLE: Y
PHONE: (916) 445-0657
FACILITY CATEGORY: SULFUR1C ACID REGENERATION PLANT
SAMPLING TECHNIQUE: MODIFIED METHOD 5 (SEMI-VOLATILE ORGANIC)(COMMENT>
ANALYTICAL METHOD: GC/MS (SEMI-VOLATILE ORGANICS) (SEE COMMENTS)
COMMENTS: SAMPLING TECHNIQUE FOR VOLATILE ORGANICS: GRAB
WITH BAG.
ANALYTICAL METHODS FOR VOLATILE ORGANICS: GC/FID
AND GC/ECD.
SYNTHETIC ORGANIC WASTES ADDED TO FUEL.
4-DIGIT SIC CODE: 2819
TEST DATE: 02/30/85
SCC
POLLUTANT NAME
CAS #
RATE
UNIT
LOCATION
3-01-023
PENTACHLOROPHENOL
TRICHLOR08ENZENE,1.2,4-
TRICHLC«OETHANE,1,1,1-
CARBON TETRACHLORIDE
87-86-5 0.0003 LBS/DY SAMPLING PORT(STACK)
120-82-1 0.0003 LBS/DY SAMPLING PORT(STACK)
71-55-6 0.0019 LBS/DY SAMPLING PORT(STACK)
56-23-5 0.0005 LBS/DY SAMPLING PORT(STACK)
ACCESS if: 73668
TEST ID NO; ARB/SS-87-02
AGENCY: CA AIR RESOURCES BOARD
TEST CONTACT: DEAN SIMEROTH
STATE: CA NOTABLE: Y
PHONE: (916) 445-0657
FACILITY CATEGORY: BURNING ORGANIC UASTES AS A SUPPLEMENT FUEL IN A
CEMENT KILN
SAMPLING TECHNIQUE: MODIFIED METHOD 5(SEMI-VOLATILE ORGANICS)(COMMENT)
ANALYTICAL METHOD: GC/MS(SEMI-VOLATILE ORGANICS) (SEE COMMENTS)
COMMENTS: SAMPLING TECHNIQUE FOR VOLATILE ORGANIC: GRAB WITH
BAG.
ANALYTICAL METHODS FOR VOLATILE ORGANIC: GC/FID
AND GC/ECD.
4-DIGIT SIC CODE: 3241
TEST DATE: 08/16/84
SCC
POLLUTANT NAME
CAS
RATE UNIT
LOCATION
VOLATILE ORGANIC COMPOUNDS
3-05-006 BENZENE
DIOXINS
CL-VOC 0.6900 LBS/DY KILN STACK
71-43-2 4.9800 LBS/DY KILN STACK
CL-DIOXIN 0.1900 MG/HR KILN STACK
332
-------
APPENDIX B. SOURCE TEST DESCRIPTIONS
ACCESS #: 73669
TEST ID NO; C-83-049
AGENCY: CA AIR RESOURCES BOARD
TEST CONTACT: DEAN SIMEROTH
FACILITY CATEGORY: SPICE MANUFACTURING STERILIZATION CHAMBER
SAMPLING TECHNIQUE: CONTINUOUS EXTRACTION TO HC ANALYZER
ANALYTICAL METHOD: FLAME IONIZATION DETECTION (FID)
COMMENTS: EMISSIONS RATE IS THE AVERAGE EMISSION RATE FROM
2-TWO HOUR + 2-THREE HOUR CYCLES.
STATE: CA NOTABLE: Y
PHONE: (916) 445-0657
4-DIGIT SIC CODE: 2099
TEST DATE: 08/04/83
SCC
POLLUTANT NAME
CAS
RATE UNIT
LOCATION
3-02-999 ETHYLENE OXIDE
75-21-8
4.9600 LBS/HR EXHAUST PIPE
ACCESS *; 73670
TEST ID NO; C-85-019
AGENCY: CA AIR RESOURCES BOARD
TEST CONTACT: DEAN SIMEROTH
STATE: CA NOTABLE: Y
PHONE: (916) 445-0657
FACILITY CATEGORY: GLASS MELTING FURNACE
SAMPLING TECHNIQUE: METHOD 5
ANALYTICAL METHOD: DIPHENYLCARBAZIDE COLORIMETRY
COMMENTS:
4-DIGIT SIC CODE: 3221
TEST DATE: 05/07/85
SCC
POLLUTANT HAME
CAS
RATE UNIT
LOCATION
3-05-014
CHROMIUM
7440-47-3
0.0000 LB/HR G.M. FURNACE STACK
ACCESS #; 73671
TEST ID NO; HMT 7645C
AGENCY: HM POLLUTION CONTROL AGENCY, DIV. OF AIR QUALITY
TEST CONTACT: ED CROWLEY
STATE: MN NOTABLE: Y
PHONE: (612) 296-7554
FACILITY CATEGORY: WAFERBOARD PLANT
SAMPLING TECHNIQUE: MODIFIED NIOSH 3500
ANALYTICAL METHOD: NIOSH 3500
COMMENTS: PLEASE NOTE THAT THIS SOURCE TEST AND TESTS MMT
7645, 7645A, AND 7645B ARE THE SAME.
4-DIGIT SIC CODE: 0000
TEST DATE: 03/11/87
SCC
POLLUTANT NAME
CAS #
RATE UNIT
LOCATION
FORMALDEHYDE
50-00-0
2.0900 LB/HR DRYER #4
333
-------
APPENDIX B. SOURCE TEST DESCRIPTIONS
ACCESS it: 73672
TEST ID NO; MMT 76458
AGENCY: MN POLLUTION CONTROL AGENCY, DIV. OF AIR QUALITY STATE: MN NOTABLE: Y
TEST CONTACT: ED CROULEY PHONE: (612) 296-7554
FACILITY CATEGORY: UAFERBOARD PLANT
SAMPLING TECHNIQUE: MODIFIED NIOSH 3500
ANALYTICAL METHOD: NIOSH 3500
COMMENTS: PLEASE NOTE THAT THIS SOURCE TEST AND TESTS MMT
7645, 7645A, AND 7645C ARE THE SAME TEST.
4-DIGIT SIC CODE: 0000
TEST DATE: 03/11/87
SCC
POLLUTANT NAME
CAS
RATE UNIT
LOCATION
FORMALDEHYDE
50-00-0
2.0700 LB/HR ECONOMIZER
ACCESS #; 73673
TEST ID NO; MMT 7645A
AGENCY: MN POLLUTION CONTROL AGENCY, DIV. OF AIR QUALITY
TEST CONTACT: ED CROULEY
STATE: MN NOTABLE: Y
PHONE: (612) 296-7554
FACILITY CATEGORY: UAFERBOARD PLANT
SAMPLING TECHNIQUE: MODIFIED NIOSH 3500
ANALYTICAL METHOD: NIOSH 3500
COMMENTS: PLEASE NOTE THAT THIS SOURCE TEST AND TEST MMT
7645, 7645B, AND 7646C ARE THE SAME.
4-DIGIT SIC CODE: 0000
TEST DATE: 03/11/87
SCC
POLLUTANT NAME
CAS
RATE UNIT
LOCATION
FORMALDEHYDE
50-00-0
0.4400 LB/HR PRESS VENT #7
ACCESS »; 73674
TEST ID NO; MMT 7645
AGENCY: MN POLLUTION CONTROL AGENCY, DIV. OF AIR QUALITY
TEST CONTACT: ED CROULEY
STATE: MN NOTABLE: Y
PHONE: (612) 296-7554
FACILITY CATEGORY: UAFERBOARD PLANT
SAMPLING TECHNIQUE: MODIFIED NIOSH 3500
ANALYTICAL METHOD: NIOSH 3500
COMMENTS: PLEASE NOTE THAT THIS SOURCE TEST AND TESTS:
MMT 7645A, 7646B, AND 7645C ARE ALL THE SAME
SOURCE TESTS BUT FOR DIFFERENT LOCATIONS.
4-DIGIT SIC CODE: 0000
TEST DATE: 03/11/87
SCC
POLLUTANT NAME
CAS
RATE UNIT
LOCATION
FORMALDEHYDE
50-00-0
0.8300 LB/HR PRESS VENT #3
334
-------
APPENDIX B. SOURCE TEST DESCRIPTIONS
ACCESS *; 73675
TEST ID NO; MMT 7644A
AGENCY: MN POLLUTION CONTROL AGENCY, DIV. OF AIR QUALITY
TEST CONTACT: ED CROULEY
FACILITY CATEGORY: UAFERBOARD PLANT
SAMPLING TECHNIQUE: MODIFIED NIOSH 3500
ANALYTICAL METHOD: NIOSH 3500
COMMENTS: NOTE THIS SOURCE TEST AND TEST #MMT 7644 ARE THE
SAME TESTS.
STATE: MN NOTABLE: Y
PHONE: (612) 296-7554
4-DIGIT SIC CODE: 0000
TEST DATE: 03/10/87
SCC
POLLUTANT NAME
CAS
RATE UNIT
LOCATION
FORMALDEHYDE
50-00-0
8.2200 LB/HR CORE DRYER
ACCESS *; 73676
TEST ID NO; MMT 7644
AGENCY: MN POLLUTION CONTROL AGENCY, DIV. OF AIR QUALITY
TEST CONTACT: ED CROWLEY
STATE: MN NOTABLE: Y
PHONE: (612) 296-7554
FACILITY CATEGORY: UAFERBOARD PLANT
SAMPLING TECHNIQUE: MODIFIED NIOSH 3500
ANALYTICAL METHOD: NIOSH 3500
COMMENTS: PLEASE NOTE THAT THIS SOURCE TEST AND MMT 7644A
ARE THE SAME PROGRAM.
4-DIGIT SIC CODE: 0000
TEST DATE: 03/10/87
SCC
POLLUTANT NAME
CAS
RATE UNIT
LOCATION
FORMALDEHYDE
50-00-0
0.7730 LB/HR PRESS VENT
ACCESS 0; 73677
AGENCY: MN POLLUTION CONTROL AGENCY, DIV. OF AIR QUALITY
TEST CONTACT: ED CROWLEY
FACILITY CATEGORY: UATERBOARD PLANT
SAMPLING TECHNIQUE: MODIFIED NIOSH 3500
ANALYTICAL METHOD: NIOSH 3500
COMMENTS:
TEST ID NO; MMT-7644
STATE: MN NOTABLE: Y
PHONE: (612) 296-7554
4-DIGiT SIC CODE: 0000
TEST DATE: 03/10/87
SCC
POLLUTANT NAME
CAS #
RATE UNIT
LOCATION
FORMALDEHYDE
50-00-0
0.7330 LB/HR PRSESS VENT
335
-------
APPENDIX B. SOURCE TEST DESCRIPTIONS
ACCESS »; 73678
TEST ID NO; ERT-AIR TOXICS
AGENCY: MN POLLUTION CONTROL AGENCY, DIV. OF AIR QUALITY
TEST CONTACT: ED CROWLEY
STATE: NN NOTABLE: Y
PHONE: (612) 296-7554
FACILITY CATEGORY: SEWAGE SLUDGE INCINERATOR - MUCC - METRO PLANT
SAMPLING TECHNIQUE:
ANALYTICAL METHOD:
COMMENTS:
VOLATILE ORGANICS- VOST (SEE COMMENTS)
VOST: THERMAL DESORPTION AND PURGEABLES FOR GC.MS
SCREENING/SEMIVOLATILES/ORGANIC EXTRACTION FOR GC/
MS ANALYSIS.
SAMPLING (CONT.): SEMIVOLATRE ORGANICS AND DIOXIN
AND FURANS: MODIFIED METHOD 5.
VOLATILES AND SEMIVOLATILE SAMPLING FOR SCREENING
ANALYSES. EMISSION RATES FOR SEXTA CHLORO FURANS
IS EQUAL TO 0.085 NG/M3 FOR INCINERATORS.
4-DIGIT SIC CODE: 0000
TEST DATE: 05/21/87
SCC POLLUTANT NAME
HEPTA CHLORO FURANS
OCTACHLOftODIBENZO-P-DIOXIN
PENTA CHLORO FURANS
TETRACHLORODIBENZODIOXIN,2,3,7,8-,P-
TRI CHLORO FURANS
2,3,7,8 TCDF
CAS *
38998-75-3
3268-87-9
30402-15-4
1746-01-6
43048-00-6
51207-31-0
RATE UNIT
0.0700 NG/M3
0.1100 NG/M3
0.3300 NG/M3
0.0200 NG/N3
0.5500 NG/M3
0.2300 NG/M3
LOCATION
INCINERATOR
INCINERATOR
INCINERATOR
INCINERATOR
INCINERATOR
INCINERATOR
ACCESS »: 73680
TEST ID NO; PACE 861022 004
AGENCY: MN POLLUTION CONTROL AGENCY, DIV. OF AIR QUALITY
TEST CONTACT: ED CROWLEY
STATE: NN NOTABLE: Y
PHONE: (612) 296-7554
FACILITY CATEGORY: HAZARDOUS WASTE INCINERATOR
SAMPLING TECHNIQUE: METHOD 5
ANALYTICAL METHOD: ATOMIC ABSORPTION SPECTROPHOT. CATCH
COMMENTS:
4-DIGIT SIC CODE: 0000
TEST DATE: 11/05/86
SCC
POLLUTANT NAME
CAS
RATE UNIT
LOCATION
CADMIUM
CHROMIUM
7440-43-9 0.0040 LB/HR INCINERATOR STACK
7440-47-3 0.0080 LB/HR INCINERATOR STACK
336
-------
APPENDIX 8. SOURCE TEST DESCRIPTIONS
ACCESS #1 73681
TEST ID NO; 1NTERPOLL 6-2253
AGENCY: MN POLLUTION CONTROL AGENCY, DIV. OF AIR QUALITY
TEST CONTACT: ED CROWLEY
STATE: NN NOTABLE: Y
PHONE: (612) 296-7554
FACILITY CATEGORY: PAPER PLANT - BOILERS
SAMPLING TECHNIQUE:
ANALYTICAL METHOD:
COMMENTS:
METHOD 5 FOR HEXANE SOLUBLE FRACTION(SEE COMMENTS)
HEXANE EXTRACTION OF FRONT AND HALF CATCH(COMMENTS
SAMPLING TECHNIQUE FOR BENZOO PYRENE (FLORISIL)
IS MODIFIED METHOD 5. ANALYTICAL METHODS INCLUDE
EVAPORATE AND GRAVIMETRIC ANALYSIS OF RESIDUE
BENZO () PYRENE: EXTRACTION WITH METHYLENE
CHLORIDE AND ANALYSIS OF CONCENTRATE BY HPLC.
4-DIGIT SIC CODE: 0000
TEST DATE: 07/30/86
SCC
POLLUTANTNAME
CAS if
RATE
UNIT
LOCATION
BENZO(A)PYRENE
HEXANE,N-
50-32-8
110-54-3
0.0050 LB/HR
5.8000 LB/HR
NO. 5 BOILER
NO. 5 BOILER
ACCESS »: 73689
TEST ID NO; PACE 851104 QUA
AGENCY: MN POLLUTION CONTROL AGENCY, DIV. OF AIR QUALITY
TEST CONTACT: ED CROWLEY
STATE: MN NOTABLE:
PHONE: (612) 296-7554
FACILITY CATEGORY: UAFERBOARD PLANT
SAMPLING TECHNIQUE:
ANALYTICAL METHOD:
COMMENTS:
FORMALDEHYDE: MODIFIED NIOSH 3500 (SEE COMMENTS)
FORMALDEHYDE: NIOSH 3500 (SEE COMMENTS)
SAMPLING TECHNIQUES: MDI- MODIFIED NIOSH METHOD
P AND CAM 142.
ANALYTICAL METHODS: MDI- NIOSH P AND CAM 142.
PLEASE NOTE: THIS SOURCE TEST AND TEST PACE 851104
014 ARE THE SAME TEST.
NEW RESIN USED AS BINDER: POLYMERIC AND MONOMER1C
4.4< DIPHENYLMETHANE DIISOCYANATE.
4-DIGIT SIC CODE: 0000
TEST DATE: 11/05/85
SCC
POLLUTANT NAME
CAS if
RATE
UNIT
LOCATION
DIPHENYLMETHANEDIISOCYANATE,4,4'- 101-68-8 0.0050 LB/HR UNLOADER VENT
FORMALDEHYDE 50-00-0 0.0300 LB/HR UNLOADER VENT
337
-------
APPENDIX B. SOURCE TEST DESCRIPTIONS
ACCESS *: 73690
TEST ID NO; INTERPOLL 5-2067A
AGENCY: NN POLLUTION CONTROL AGENCY, 0IV. OF AIR QUALITY
TEST CONTACT: ED CROULEY
STATE: MN NOTABLE: Y
PHONE: (612) 296-7554
FACILITY CATEGORY: UAFERBOARO PLANT
SAMPLING TECHNIQUE: FORMALDEHYDE -MODIFIED N10SH 3500
ANALYTICAL METHOD: FORMALDEHYDE -N10SH 3500
COMMENTS: THIS SOURCE TEST IS THE SAME AS INTERPOLL 5-2067,
THIS REPORT IS A CONTINUENCE OF THAT FOR FORMALDE-
HYDE.
4-DIGIT SIC CODE: 0000
TEST DATE: 08/21/85
SCC
POLLUTANT NAME
CAS
RATE
UNIT
LOCATION
FORMALDEHYDE
50-00-0
5.2300 LB/HR PRESS BOARD (ONE)
ACCESS »: 73691
TEST ID NO; PACE 851104 014
AGENCY: MN POLLUTION CONTROL AGENCY, DIV. OF AIR QUALITY
TEST CONTACT: ED CROULEY
STATE: MN NOTABLE: Y
PHONE: (612) 296-7554
FACILITY CATEGORY: UAFERBOARO PLANT
SAMPLING TECHNIQUE:
ANALYTICAL METHOD:
COMMENTS:
FORMALDEHYDE: MODIFIED NIOSH 3500 (SEE COMMENTS)
FORMALDEHYDE: NIOSH 3500_(SEE COMMENTS)
SAMPLING TECHNIQUE FOR MDI - MODIFIED NIOSH METHOD
P AND CAM 142. ANALYTICAL TECHNIQUE ARE NIOSH
P AND CAM 142.
NOTE: THIS SOURCE TEST AND TEST: PACE 851104 014A
ARE THE SAME SOURCE TEST.
NEW RESIN USED AS BINDER: POLYMERIC AND MONGER1C
4,4' DIPHENYLMITHANE DIISOCYANATE.
4-DIGIT SIC CODE: 0000
TEST DATE: 11/05/85
SCC
POLLUTANT NAME
CAS
RATE UNIT
LOCATION
DIPHENYLMETHANEDIISOCYANATE.4,4'- 101-68-8 0.0050 LB/HR PRESS VENT
FORMALDEHYDE 50-00-0 0.0380 LB/HR PRESS VENT
338
-------
APPENDIX B. SOURCE TEST DESCRIPTIONS
ACCESS 0; 73692
TEST IP NO; 1NTERPOLL 5-2067
AGENCY: MM POLLUTION CONTROL AGENCY, DIV. OF AIR QUALITY
TEST CONTACT: ED CROWLEY
STATE: NN NOTABLE: Y
PHONE: (612) 296-7554
FACILITY CATEGORY: WAFERBOARD PLANT
SAMPLING TECHNIQUE: FORMALDEHYDE-MODIFIED N10SH 3500 (SEE COMMENTS)
ANALYTICAL METHOD: FORMALDEHYE-N10SH 3500 (SEE COMMENTS)
COMMENTS: SAMPLING TECHNIQUE FOR PHENOL: METH SCRUBBERS
WITH 1 N SODIUM HYDROXIDE.
ANALYTICAL METHOD FOR PHENOL: EPA METHOD #604.
USE PHENOLIC RESIN AS BINDER.
SEE INTERPOLL 5-2067A EQUALS THE SAME SOURCE TEST.
4-DIGIT SIC CODE: 0000
TEST DATE: 08/21/85
SCC
POLLUTANT NAME
RATE UNIT
LOCATION
FORMALDEHYDE
PHENOL
50-00-0
108-95-2
10.9700 LB/HR
0.5300 LB/HR
UAFERBOAD
PRESS VENT (ONE)
ACCESS#: 73698
TEST ID NO; CEMENT PL 1985
AGENCY: SO DEPT. OF WATER & NAT. RES., OFFICE OF AIR QUALITY
TEST CONTACT: DAVE LENINGTON
STATE: SO NOTABLE: Y
PHONE: (605) 773-3153
FACILITY CATEGORY: CEMENT PLANT
SAMPLING TECHNIQUE: PITOT TUBE WITH GLASS, QUARTZ, & TEFLON FILTERS
ANALYTICAL METHOD: X-RAY FLOURENSCENCE (XRF) & ELECTRON MICROSCOPY
COMMENTS: TWO DIFFERENT METHOD 5'S WERE TRIED. IN ONE THE PR
QBE WAS WASHED IN ACETONE. IN THE OTHER THE PROBE
WAS WASHED IN WATER. AMMONIUM CHLORIDE CONCENTRATI
ONS WERE HIGHER IN THE WATER WASH TESTS. THREE DIF
FERENT TYPES OF FILTERS WERE ALSO TRIED.
4-DIGIT SIC CODE: 3241
TEST DATE: 06/04/85
SCC
POLLUTANT NAME
CAS
RATE
UNIT
LOCATION
3-05-006-06 AMMONIA
3-05-006-06 AMMONIUM CHLORIDE-FUME
7664-41-7 0.0000 LBS/HR DRY KILN #6
12125-02-9 4.9200 LBS/HR DRY KILN #6
339
-------
APPENDIX B. SOURCE TEST DESCRIPTIONS
ACCESS »! 73700 TEST ID NO; CA-SAC-01
AGENCY: SACRAMENTO CO. AIR POLLUTION CONTROL DISTRICT STATE: CA NOTABLE: Y
TEST CONTACT: ERIC SKELTON PHONE: (916) 366-2107
FACILITY CATEGORY: RESIN MANUFACTURING 4-DIGIT SIC CODE: 2821
TEST DATE: 04/07/86
SAMPLING TECHNIQUE: SODIUM BISULTITE IMPINGER
ANALYTICAL METHOD: CHROMOTROPIC ACID SODIUM SALT/SPECTROPHOTOMETER
COMMENTS: PLEASE NOTE THAT FOR CAS* 50-00-0 THE EMISSION
RATES VALUE WAS ENTERED AS 00000000. THIS VALUE
WAS GIVEN TO INDICATE THAT VARIOUS EMISSIONS
VALUES HAVE BEEN MEASURED FOR THIS POLLUTANT.
SCC POLLUTANT NAME CAS » RATE UNIT LOCATION
3-01-999-99 FORMALDEHYDE 50-00-0 0.0000 G/HR VACUUM PUMP VENT
ACCESS »: 73714 TEST ID NO; CL-MT-ST-3
AGENCY: MT DEPT. OF HEALTH AND ENV. SCIENCES, AIR QUALITY BUREAU STATE: MT NOTABLE: Y
TEST CONTACT: HARRY KELTZ PHONE: (406) 444-3454
FACILITY CATEGORY: PULP AND PAPER MILL 4-OIGIT SIC CODE: 2621
TEST DATE: 05/00/83
SAMPLING TECHNIQUE: WET SCRUBBER, ESP
ANALYTICAL METHOD:
COMMENTS:
SCC POLLUTANT NAME CAS # RATE UNIT LOCATION
TOTAL REDUCED SULFUR CL-TRS 0.4000 PPM RECOVERY FURANCE
340
-------
APPENDIX B. SOURCE TEST DESCRIPTIONS
ACCESS #: 73715
AGENCY: NT OEPT. OF HEALTH AND ENV. SCIENCES, AIR QUALITY BUREAU
TEST CONTACT: HARRY KELTZ
FACILITY CATEGORY: PRIMARY ALUMfNIM SMELTER
TEST ID NO; CL-MT-ST-4A
STATE: MT NOTABLE: Y
PHONE: (406) 444-3454
4-DIGIT SIC CODE: 3334
TEST DATE.- 12/00/86
SAMPLING TECHNIQUE: METHOD 13
ANALYTICAL METHOD: AUTOMATED UILLARD-UINTER DISTILLATION
COMMENTS: PLEASE NOTE THAT THIS SOURCE TEST AND TEST
CL-MT-ST-4 ARE THE SAME, BUT DUE TO NATICH
RESTRICTIONS THEY MUST BE SEPERATED. PLEASE ALSO
NOTE THAT THIS TEST (CL-HT-ST-4A) IS IN REFERENCE
TO FLUORIDES(ROOFS) (SECONDARY SYSTEM).
see
POLLUTANT NAME
CAS *
RATE
UNIT
LOCATION
3-03-001-03 FLUORIDES
16984-48-8 800.0000 LB/DAY POT-LINES
ACCESS 9: 73716
TESTID NO; CL-MT-ST-4
AGENCY: MT DEPT. OF HEALTH AND ENV. SCIENCES, AIR QUALITY BUREAU
TEST CONTACT: HARRY KELTZ
STATE: MT NOTABLE: Y
PHONE: (406) 444-3454
FACILITY CATEGORY: PRIMARY ALUMINUM SMELTER
SAMPLING TECHNIQUE: METHOD 13
ANALYTICAL METHOD: AUTOMATED UILLARD-UINTER DISTILLATION
COMMENTS: THIS SOURCE TEST AND CL-MT-ST-4 ARE THE SAME,
BUT DUE TO NATICH RESTRICTIONS THEY MUST BE
SEPERATED. PLEASE NOT THAT THIS P6RMIT(CL-MT-ST-4)
IS REFERENCED FOR FLUORIDES(PRIMARY SYSTEM).
4-DIGIT SIC CODE: 3334
TEST DATE: 12/00/86
SCC
POLLUTANT NAME
CAS #
RATE
UNIT
LOCATION
3-03-001-03 FLUORIDES
16984-48-8 46.0000 LD/DAY POT-LINES
341
-------
APPENDIX B. SOURCE TEST DESCRIPTIONS
ACCESS «; 73718
TEST ID KO; 1
AGENCY: TULSA CITY-COUNTY HEALTH DEPT., AIR QUALITY CONTROL
TEST CONTACT: RAY BISHOP
STATE: OK NOTABLE: Y
PHONE: (918) 744-1000
FACILITY CATEGORY: MUNICIPAL TRASH INCINERATOR
SAMPLING TECHNIQUE: MODIFIED METHOD 5
ANALYTICAL METHOD:
COMMENTS: NONE
4-DIGIT SIC CODE: 4953
TEST DATE: 06/00/86
SCC POLLUTANT NAME
FLUORIDES
DIOXINS
FURANS
CAS #
16984-48-8
CL-OIOXIN
CL-FURAN
RATE UNIT LOCATION
0.7200 LBS/HR STACK
18.9320 NG/NM3 STACK
15.5200 NG/NM3 STACK
ACCESS »; 73727
TEST ID NO; 07-22-86
AGENCY: SOUTH WEST AIR POLLUTION CONTROL AUTHORITY
TEST CONTACT: DAVID MOORE
STATE: UA NOTABLE: Y
PHONE: (206) 574-3058
FACILITY CATEGORY: TIRE PYROLYSIS
SAMPLING TECHNIQUE:
ANALYTICAL METHOD:
COMMENTS:
VOST, SEMI-VOST, MODIFIED METHODS
GC/MS INDUCTIVE PLASMA SPECTROSCOPY AA
NONCONTACT PYROLYSIS. SAMPLING AT BURNER CHAMBER
EXHAUST-(PYRO GAS IS COLLECTED AND INCINERATED
SEPERATELY AS WELL AS BEING USED TO FIRE THE BURN-
ERS).
4-OIGIT SIC CODE: 4953
TEST DATE: 07-22-86
SCC
POLLUTANT NAME
CAS
RATE UNIT
LOCATION
BENZENE
BUTYL BENZYL PHTHALATE
CHROMIUM
DI-N-BUTYL PHTHALATE
ETHYL BENZENE
ETHYLHEXYLPHTHALATE , B I S , 2 •
MAGNESIUM
MANGANESE
MERCURY
NAPHTHALENE
NICKEL
PHENOL
TOLUENE
XYLENE
ZINC
71-43-2
85-68-7
7440-47-3
84-74-2
100-41-4
117-81-7
7439-95-4
7439-96-5
7439-97-6
91-20-3
7440-02-2
108-95-2
108-88-3
1330-20-7
7440-66-6
29
2
0
1
45
22
0
0
0
4
4
2
43
.6000
.2000
.8600
.1000
.1000
.9000
.5000
.1000
.0800
.6000
.3100
.4000
.0000
33.9000
1
.0100
UG/M3
UG/M3
UG/M3
UG/M3
UG/M3
UG/M3
UG/M3
UG/M3
UG/M3
UG/M3
UG/M3
UG/M3
UG/M3
UG/M3
UG/M3
PYRO.
CHAM.
EXHAUST
PYRO.CHAM. EXHAUST
PYRO.
PYRO.
PYRO.
PYRO.
PYRO.
PYRO.
PYRO.
PYRO.
PYRO.
PYRO.
PYRO.
PYRO.
PYRO.
CHAM.
CHAM.
CHAM.
CHAN.
CHAM.
CHAM.
CHAM.
CHAM.
CHAM.
CHAM.
CHAM.
CHAM.
CHAM.
EXHAUST
EXHAUST
EXHAUST
EXHAUST
EXHAUST
EXHAUST
EXHAUST
EXHAUST
EXHAUST
EXHAUST
EXHAUST
EXHAUST
EXHAUST
342
-------
APPENDIX B. SOURCE TEST DESCRIPTIONS
ACCESS »: 73728
AGENCY: tOUA DEPT. OF NATURAL RESOURCES
TEST CONTACT: DAVE PNELPS
FACILITY CATEGORY: PESTICIDES AND AGRICULTURAL CHEMICALS
SAMPLING TECHNIQUE: STANDARD PARTICULATE SAMPLING METHODS
ANALYTICAL METHOD: STANDARD PARTICULATE METHOD INCLUDING BACK HALF
COMMENTS: CATCH.
CARBAMATE PESTICIDE BROOL.
TEST ID NO; lA-DNR-01
STATE: IA NOTABLE: Y
PHONE: (515) 281-8925
4-DIGIT SIC CODE: 2879
TEST DATE: 01-13-87
set
POLLUTANT NAME
CAS *
RATE UNIT
LOCATION
TRIMETHYLPHENYL N-METHYLCARBAMATE
58784-13-7 0.0144 GR/SCF POOCESS
ACCESS »; 73755
AGENCY: CHATTANOOGA-HAMILTON CO. AIR POLLUTION CONTROL BUREAU
TEST CONTACT: DALE E. FENTRESS
TES.T ID NO; 3500-65-1A
STATE: TN NOTABLE: Y
PHONE: (615) 867-4321
FACILITY CATEGORY: CHEMICAL MANUFACTURING FACILITY
SAMPLING TECHNIQUE: TEDLAR BAGS; EVACUATION THROUGH HCL AND SILICA GEL
ANALYTICAL METHOD: GC/FID
COMMENTS: DREACTOR CHARGING; 2>uNusuAL SAMPLING PROCEDURE
IN THAT THE SAMPLE WAS OBTAINED WITH TEDLAR BAGS
AND THEN ABSORBED IN A 3X HCL SOLUTION AND SILICA
GEL. THE SAMPLES WERE THEN EXTRACTED WITH CARBON
DISULFIDE AND ANALYZED USING A GAS CHROMATOGRAPH
WITH A FLAME IONIZATION DETECTOR.
4-DIGIT SIC CODE: 2819
TEST DATE: 09/11/84
ACCESS it: 73756
TEST ID NO; 3500-60-1
AGENCY: CHATTANOOGA-HAMILTON CO. AIR POLLUTION CONTROL BUREAU
TEST CONTACT: DALE E. FENTRESS
STATE: TN NOTABLE: Y
PHONE: (615) 867-4321
FACILITY CATEGORY: CHEMICAL MANUFACTURING PLANT
SAMPLING TECHNIQUE: PARTICULATE SAMPLING-EPA METHODS 1-5
ANALYTICAL METHOD:
COMMENTS:
4-DIGIT SIC CODE: 2819
TEST DATE: 03/21/80
SCC
POLLUTANT NAME
CAS #
RATE UNIT
LOCATION
1-02-013-01 COBALT
7440-48-4
0.8250 LB/HR COMBUSTION EQUIPMENT
343
-------
APPENDIX B. SOURCE TEST DESCRIPTIONS
ACCESS »; 73797
TEST ID NO; 7216-1
AGENCY: NJ DEPT. OF ENV. PROT., BUR. OF AIR POLLUTION CONTROL
TEST CONTACT: LOU MIKOLAJCZYIC
STATE: NJ NOTABLE: Y
PHONE: (609) 530-4042
FACILITY CATEGORY: DRY CLEANING
SAMPLING TECHNIQUE: INTEGRATED GAS BAG SAMPLE
ANALYTICAL METHOD: FID
COMMENTS:
4-DIGIT SIC CODE: 7216
TEST DATE: 06-12-84
SCC
POLLUTANT NAME
CAS
RATE UNIT
LOCATION
TETRACHLOROETHYLENE
127-18-4
0.0330 LB/HR VENT FROM CARBON
ACCESS *; 98990
TEST ID NO; CA-SACCQ-02
AGENCY: SACRAMENTO CO. AIR POLLUTION CONTROL DISTRICT
TEST CONTACT: ERIC SKELTON
STATE: CA NOTABLE: Y
PHONE: (916) 366-2107
FACILITY CATEGORY: CHEMICAL MANUFACTURING (AEROSPACE AND MILITARY
PRODUCTS)
SAMPLING TECHNIQUE: CHARCOAL TUBE
ANALYTICAL METHOD: GC/ECO
COMMENTS: INFRARED ANALYZERS ARE USED AS CONTINUOUS EMISSION
MONITORS ON CHLOROFORM AND ETHYLENE DICHLORIDE
EMIS.
4-DIGIT SIC CODE: 2819
TEST DATE: VARIOUS
SCC
POLLUTANT NAME
CAS *
RATE UNIT
LOCATION
3-01-999-99 CHLOROFORM
3-01-999-99 ETHYLENE DICHLORIDE
3-01-999-99 TOLUENE
67-66-3
107-06-2
108-88-3
0.0000 VAR.
0.0000 VAR.
0.0000 VAR
CONTROL DEVICE VENT
CONTROL DEVICE VENT
CONTROL DEVICE VENT
344
-------
APPENDIX B. SOURCE TEST DESCRIPTIONS
ACCESS it: 99791
TEST ID NO; MM4
AGENCY: HN POLLUTION CONTROL AGENCY, DIV. OF AIR QUALITY
TEST CONTACT: ED CROULEY
STATE: MM NOTABLE: Y
PHONE: (612) 296-7554
FACILITY CATEGORY: GOPHER SMELTING-SECONDARY LEAD SMELTER
SAMPLING TECHNIQUE: METHOD 5, 0.5 HA OH SOLUTION IN IMPINGERS
ANALYTICAL METHOD: ATOMIC ABSORPTION
COMMENTS: FILTER CATCH & IMPINGER HA OH SOL. ANALIZED TO IN-
CLUDE NON VOLATILE AND VOLATILE FORMS OF ARSENIC.
4-DIG1T SIC CODE: 3341
TEST DATE: 01/17/85
SCC
POLLUTANT NAME
CAS
RATE
UNIT
LOCATION
ARSENIC AND COMPOUNDS AS AS
7440-38-2
0.0025 LB/HR BLAST FURNACE STACK
ACCESS #: 99792
TEST ID NO-. MN3
AGENCY: MN POLLUTION CONTROL AGENCY, DIV. OF AIR QUALITY
TEST CONTACT: ED CROWLEY
STATE: MN NOTABLE: Y
PHONE: (612) 296-7554
FACILITY CATEGORY: 3 M CHEMOL1TE INCINERATOR
SAMPLING TECHNIQUE: EPA METHOD 5 WITH HC1 ABSORBED IN WATER
ANALYTICAL METHOD: ATOMIC ABSORBTION FOR CD & CR, & ION CHROMA-
COMMENTS: TOGRAPHY FOR C1
TOGRAPHY FOR C1
4-DIGIT SIC CODE: 4953
TEST DATE: 08/19/86
SCC POLLUTANT NAME
CADMIUM
CHROMIUM
HYDROGEN CHLORIDE
CAS #
7440-43-9
7440-47-3
7647-01-0
RATE UNIT LOCATION
0.0020 KG/HR INCINERATOR
0.0001 KG/HR INCINERATOR
0.0500 KG/HR INCINERATOR
345
-------
APPENDIX B. SOURCE TEST DESCRIPTIONS
ACCESS #! 99793
TEST ID HO; MN2
AGENCY: MN POLLUTION CONTROL AGENCY, OIV. OF AIR QUALITY
TEST CONTACT: ED CROWLEY
STATE: MN NOTABLE: Y
PHONE: (612) 296-7554
FACILITY CATEGORY: IMPERIAL LAND 0< LAKES-PESTICIDE FORMULATION
SAMPLING TECHNIQUE:
ANALYTICAL METHOD:
COMMENTS:
SAMPLING TRAIN AS IN METHOD 6.C2H602 ABSORBENT
GAS CHROMATOGRAPHY AS IN EPA MANUAL FOR PESTICIDES
PESTICIDES SAMPLED AS GAS OR VAPORS,FILTER USED TO
KEEP PART. FROM ENTERING IMPING., ANALIZED ASBORB.
4-DIGIT SIC CODE: 2879
TEST DATE: 12/17/85
SCC
POLLUTANT NAME
CAS #
RATE
UNIT
LOCATION
COUNTER 15 G
PHORATE
13071-79-9
298-02-2
0.0000
0.0000
CARBON FILTER PROC.
ACCESS if: 99794
TEST ID NO; MN1
AGENCY: MN POLLUTION CONTROL AGENCY, DIV. OF AIR QUALITY STATE: MN NOTABLE: Y
TEST CONTACT: ED CROULEY PHONE: (612) 296-7554
FACILITY CATEGORY: POTLATCH CORPORATION-CLOQUET
SAMPLING TECHNIQUE: EPA METHOD 6 SAMPLING TRAIN,IM NAOH SCRUBBING SOL.
ANALYTICAL METHOD: ION CHROMATOGRAPHY
COMMENTS:
4-DIGIT SIC CODE: 0000
TEST DATE:
SCC
POLLUTANT NAME
CAS
RATE UNIT
LOCATION
CHLORINE
CHLORINE DIOXIDE
7782-50-5 0.8800 LB/HR BLEACH S.T.SCRUBBER
10049-04-4 0.3000 LB/HR CL02 SEAL TANK SCRUB
346
-------
APPENDIX B. SOURCE TEST DESCRIPTIONS
ACCESS if: 99838
TEST ID NO: CL-NV-L.VEGAS-ST-3
AGENCY: AIR POLLUTION CONTROL DIV., DIST. HEALTH DEPT. OF CLARK CO.
TEST CONTACT: DAVID LEE
FACILITY CATEGORY: CHEMICAL MANUFACTURING
(HAZARDOUS WASTE MANAGEMENT)
SAMPLING TECHNIQUE: CL: BUBBLER TRAIN; OTHERS:DIRECT INJECTION
ANALYTICAL METHOD: CL: IDOMETRY; OTHERS: GC/MS
COMMENTS:
STATE: NV NOTABLE: Y
PHONE: (702) 383-1276
4-DIGIT SIC CODE: 2812
TEST DATE: DEC 86
sec
POLLUTANT NAME
CAS t
RATE UNIT
LOCATION
CHLOROFORM
CHLOROTHIOANISOLE
DICHLOROBENZENE,1,2-
MONOCHLOROBENZENE
TR I CHLOROBENZENE ,1,2,4-
BENZENE
CHLORINE
67-66-3
123-09-1
95-50-1
108-90-7
120-82-1
71-43-2
7782-50-5
35.0000
0.1000
5.0000
23.0000
0.2000
20.9000
0.0100
LB/D
LB/D
LB/D
LB/D
LB/D
LB/D
LB/HR
PROCESS
PROCESS
PROCESS
PROCESS
PROCESS
PROCESS
PROCESS
ACCESS »; 99839
TEST ID NO; CI-NV-L.VEGAS-ST-2
AGENCY: AIR POLLUTION CONTROL DIV., DIST. HEALTH DEPT. OF CLARK CO. STATE: NV NOTABLE: Y
TEST CONTACT: DAVID LEE PHONE: (702) 383-1276
FACILITY CATEGORY: PEPCON AMMONIUM PERCHLORATE MANUFACTURE
4-DIGIT SIC CODE: 2819
TEST DATE: 1984
SAMPLING TECHNIQUE: CL - BUBBLER TRAIN
ANALYTICAL METHOD: CL • IODOMETRY
COMMENTS:
NH3 - CONTINUOUS MONITORING
NH3 • CHEMILUMINESCENCE
_§££_
POLLUTANT NAME
CAS *
RATE
UNIT
LOCATION
AMMONIA
CHLORINE
7664-41-7 0.5000 LB/HR PROCESS
7782-50-5 1.0000 LB/HR PROCESS
347
-------
APPENDIX B. SOURCE TEST DESCRIPTIONS
ACCESS »; 99840
TEST ID NO; CI-NV-L.VEGAS-ST-1
AGENCY: AIR POLLUTION CONTROL DIV., DIST. HEALTH DEPT. OF CLARK CO. STATE: NV NOTABLE: Y
TEST CONTACT: DAVID LEE PHONE: (702) 383-1276
FACILITY CATEGORY: KERR MCGEE CHEMICAL CO.
AMMONIUM PERCHLORATE MANUFACTURE
SAMPLING TECHNIQUE: CL • BUBBLER TRAIN NH3 - CONTINUOUS MONITORING
ANALYTICAL METHOD: CL • IDOMETRY NH3 - CHEMILUMINESCENCE
COMMENTS:
4-DIGIT SIC CODE: 2819
TEST DATE: 1984
SCC
POLLUTANT NAME
CAS #
RATE UNIT
LOCATION
AMMONIA
CHLORINE
7664-41-7 5.0000 LB/HR PROCESS
7782-50-5 2.0000 LB/HR PROCESS
ACCESS »: 99867
TEST ID MO; CL-MT-ST-2
AGENCY: MT DEPT. OF HEALTH AND ENV. SCIENCES, AIR QUALITY BUREAU
TEST CONTACT: HARRY KELTZ
STATE: MT NOTABLE: Y
PHONE: (406) 444-3454
FACILITY CATEGORY: PULP AND PAPER MILL
SAMPLING TECHNIQUE:
ANALYTICAL METHOD:
COMMENTS:
4-DIGIT SIC CODE: 2621
TEST DATE: MAY 83
SCC
POLLUTANT NAME
CAS if
RATE UNIT
LOCATION
TOTAL REDUCED SULFUR
CL-TRS
1.1000 PPM LIME KILN
ACCESS »; 99868
TEST ID NO; CL-MT-ST-1
AGENCY: MT DEPT. OF HEALTH AND ENV. SCIENCES, AIR QUALITY BUREAU
TEST CONTACT: HARRY KELTZ
STATE: MT NOTABLE: Y
PHONE: (406) 444-3454
FACILITY CATEGORY: PULP AND PAPER MILL
SAMPLING TECHNIQUE:
ANALYTICAL METHOD:
COMMENTS:
4-DIGIT SIC CODE: 2621
TEST DATE: MAY 83
SCC
POLLUTANT NAME
CAS #
RATE UNIT
LOCATION
TOTAL REDUCED SULFUR
CL-TRS
0.4000 PPM RECOVERY FURNACE
348
-------
APPENDIX B. SOURCE TEST DESCRIPTIONS
ACCESS *; 99874
TEST ID NO; Cl-HD-ST-2
AGENCY: MD DEPT. OF HEALTH & MENTAL HYGIENE, AIR MANAGEMENT ADMIN. STATE: MO NOTABLE: Y
TEST CONTACT: DONALD ANDREW PHONE: (301) 225-5245
FACILITY CATEGORY: DRUM MIX ASPHALT PLANT
SAMPLING TECHNIQUE: SINCE STAGE SORBENT TUBES/XAD-2 i TENAX SORBENT
ANALYTICAL METHOD: GC/MS
COMMENTS: DATA TO BE PRESENTED AT 1985 APCA CONVENTION
4-DIGIT SIC CODE: 2951
TEST DATE: 1984
349
-------
APPENDIX C
CLEARINGHOUSE CAS NUMBERS
Information on toxic air pollutants is entered into the data base,
stored, and reported by Chemical Abstracts Service Registry Number (CAS
number). Clearinghouse acronyms prefaced with "CL- " have been assigned to
groups of similar pollutants where no CAS number was applicable. Appendix C
provides a list of Clearinghouse chemical acronyms used in place of the CAS
number.
351
-------
in
Of
ui
o
ee ui
co uj t- o
tO
Sg§
Si
:=|2u
CO X —
I Z
Ul « O Ul
: y o « x
CO CO CO CO CO < UJ -1 UJ
t—ujuiui_jUQeca_ii
— <H-t->>^:
a.a.cTa.cecccococococn
ddddudddddddddddddd
z 3 * co o ~ co
ui « -i z o o i—
_i co < co < p u sc >
>- Z U CO Z —• <_1 •< Q
co x Poop _i c/> m ui
co o • co a z — P co o 3 co
o z uj oc a 3 (/> u<-> i- u. ui
z 3 z < >- O co co >- x
3 am LJZCI.I-" Q -J ui V) —i o
£— C3 Ul < Ul 04
3 —If- t— > Ul
_ _ U _IUIU1< ZOT— z
co p co u i- oe ui 3 i- z u.z3z uiuioe
UJ O CO UJ - UJ
:toS§««Sz"StZ"^ " "~ "
i^P^!
JS
—i a.
: co a. $
co
> i-
co <
z!
o|
CO I— X
a < o
_ _ i— ui at
u O > co —
ae o 3 •— a.
— u o u. 1/1
< — o co co
t CJ X CO CO
I ••* UJ Ul Ul
— Q I-
UIUJCJPU-ZZ>—IO-I >- CO Z >- O I- P < Z<— -I—I_1UJLUPI— —<_)(_>(-> — CO <
z z zp — --_IUZPCO coujouce<—i<<<>-i—coui x — >- o —i 3:
— uj —i _ c>£ cc « ca»«xuiQ»*aeouizxaeOQC3-JC£ococ<<>-Ozoo—-)-i-zco
fl£i^»^Ok^OZtHOC«J«J^^UI>~UIUl*^O^Cl.f* — ' — — — — — ' ' " — . — .-..—
-
>a.cooc_i
of
o
e
X Ul
.1 V —I ^ ZV« U1U1O
Q3 -JOZ •• Ull/> < VICD I— h- CO
SW _J < UJ P — P P Z X < CO O-13— < ~ P
& u. ui co t/5 x j Zj < S 3 « cc < Q u. of K ee. i
l_IUIUIH-^Ul»«O(/>a.UICtf«lN
-------