EPA/600/SR-92/104 August 1992
              ESPVI  4.0  Electrostatic
              Precipitator  V-l and
              Performance  Model:  User's
              Manual
              Phil A. Lawless
               The User's Manual is the companion
              document for the microcomputer pro-
              gram ESPVI 4.0, Electrostatic Precipi-
              tator V-l and Performance Model. The
              program was developed to provide a
              user-friendly interface to an advanced
              model  of electrostatic precipitation
              (ESP) performance. The program is ca-
              pable of modeling standard ESP con-
              figurations as well as those that might
              be proposed for improved performance.
              It incorporates many of the latest de-
              velopments  in prediction of ESP per-
              formance, including electrical waveform
              effects, non-rapping reentrainment, and
              electrode misalignment.
               This Project Summary was developed
              by EPA's Air and Energy Engineering
              Research Laboratory, Research Tri-
              angle Park, NC, to announce key find-
              ings of the research project that is fully
              documented In a separate report of the
              same title (see Project Report ordering
              Information at back).


              The Manual
               The  manual provides the documenta-
              tion needed to load the program from  its
              disks, sets up the computer configuration
              for optimal operation, and introduces the
              operation of the program. The user is ex-
              pected to be familiar with the operation of
              an ESP and  know the important factors
              that affect it. An example ESP is provided
              with the program to help with the manual's
              exposition. It  is taken from a report de-
              scribing measurement of the unit's perfor-
              mance and so provides a direct compari-
              son of the model's predictions.
  The  program consists of  a series  of
menu screens; the document is similarly
organized, with increasing levels of detail
provided as the menus become more spe-
cific. Finally, a section on the underlying
algorithms discusses typical  values that
might be encountered with the model.
                                                        Printed on Recycled Paper

-------
 Phil A. Lawless is with Research Triangle Institute, Research Triangle Park, NC
   27709
 Norman Plaks is the EPA Project Officer (see below).
 The complete report consists of paper copy and diskette, entitled "ESPVI 4.0
   Electrostatic Precipitator V-l and Performance Model: User's Manual:
    Paper Copy (Order No. PB 92-169 614/AS; Cost: $19.00, subject to change)
    Diskette (Order No. PB 92-502 251/AS; Cost: $90.00, subject to change)
    (Cost of diskette includes paper copy.)
 The above items will be available only from:
        National Technical Information Service
        5285 Port Royal Road
        Springfield, VA 22161
        Telephone: 703-487-4650
 The EPA Project Officer can be contacted at:
        Air and Energy Engineering Research Laboratory
        U.S. Environmental Protection Agency
        Research Triangle Park, NC 27711
United States
Environmental Protection Agency
Center for Environmental Research Information
Cincinnati, OH 45268

Official Business
Penalty for Private Use
$300
      BULK RATE
POSTAGE & FEES PAID
         EPA
   PERMIT No. G-35
EPA/6QO/SR-92/104

-------