Survey of Technologies
for Monitoring
Containment Liners and
Covers
  Existing sandstone
    quarry
                - Insulating 2.5mm high-density
                polyethylene liner
                    L Grid of monitoring
                    electrodes
                               20m
                            Bentonite enhanced sand
                  -A-
                             395100.00 395140.00 395180.00 395220.00 395260.M

-------

-------
                  Solid Waste and              EPA542-R-04-013
                  Emergency Response          June 2004
                  (5102G)                    http://cluin.org
                                           www.epa.gov/tio
Survey of Technologies for Monitoring
    Containment Liners and Covers
            U.S. Environmental Protection Agency
         Office of Solid Waste and Emergency Response
    Office of Superfund Remediation and Technology Innovation
                 Washington, DC 20460
                                             PUnM offli SoyfCmla Ink on pwer that
                                               « MH 50% ncycM tt»r

-------

-------
                            NOTICE AND DISCLAIMER

This report has been funded wholly by the U.S. Environmental Protection Agency (EPA) under Contract
Numbers 68-W-00-084 and 68-W-03-038. It is intended solely to provide general information about
current technologies for monitoring containment liners and covers. The report is not intended, nor can it
be relied upon to create any rights enforceable by any party in litigation with the United States. Mention
of trade names or commercial products does not constitute endorsement or recommendation for use.
Cover illustrations are reprinted from Ground Water Monitoring & Remediation with permission of the
National Ground Water Association. Copyright 1997.

Copies of this report are available free of charge from the National Service Center for Environmental
Publications (NSCEP), P.O. Box 42419, Cincinnati, OH 45242-0419; telephone (800) 490-9198 or
(513) 490-8190; or facsimile (513) 489-8695. Refer to document EPA 542-R-04-013, Survey of
Technologies for Monitoring Containment Liners and Covers. This document can also be obtained
through EPA's Hazardous Waste Clean-Up Information (CLUIN) System on the Web at http://cluin.org.

For more information about this report, please contact: Kelly Madalinski, U.S. Environmental Protection
Agency, Technology Innovation Program (5102G), 1200 Pennsylvania Avenue, NW, Washington, DC
20460; telephone (703) 603-990lor email  madalinski.kellv@epa.gov.
                               ACKNOWLEDGMENT

Special acknowledgment is given to the federal and state staff and other remediation professionals for
providing information for this document. Their cooperation and willingness to share then" expertise
about existing and potential technologies to provide innovative long-term monitoring on the integrity of
containment liners and covers encourages their application at other sites.

-------

-------
                                EXECUTIVE SUMMARY

 Regulations governing the design of engineered liners and covers for hazardous waste landfills and
 surface impoundments were issued in 1982 with the promulgation of Resource Conservation and
 Recovery Act (RCRA) Subtitle C rules. These regulations were performance based and required
 installation of a double liner system and a cover having a permeability equal to or less than that of the
 liner system. The goal of RCRA Subtitle C landfill regulations was to ensure that the primary liner and
 leachate collection system collect and treat any liquids that enter a containment unit. Because Subtitle C
 containment units receive hazardous wastes, a second composite liner with a leachate collection system
 beneath the primary liner was required. In effect, this second liner acts as a leak detection system for the
 primary liner and serves as a backup barrier to contain any leachate that manages to penetrate the
 primary liner. With the compacted soil base of the liner and the very low leachate head expected to exist
 on the overlying geomembrane, regulators anticipated that there would be minimal chance of a release of
 leachate to the environment.

 In 1991, the Environmental Protection Agency (EPA) promulgated RCRA Subtitle D rules, regulating
 the design of engineered liners and covers for municipal solid waste landfills. These regulations were
 also performance based and specified a composite liner construction, or its equivalent, and a cover
 having a permeability of 10~5 cm/s or less, or equal to or less than the liner system.  Since co-disposal
 with hazardous wastes was no longer allowed, regulators determined that the leachate generated at
 municipal solid waste landfills would be considerably less of an environmental problem than at
 hazardous landfills. Thus, only one composite liner was deemed necessary.

 Regulations under Subtitles C and D identify several common methods for measuring the performance
 of liner and cover systems, including the visual inspection of covers, observation of leachate levels and
 rates, and installation of groundwater quality monitoring wells downgradient of the landfill. This report
 examines a variety of technologies that can further measure performance of covers and liners. Liner
 technologies monitor the vadose zone beneath containment system liners and/or provide an early
 warning of releases before they can have an impact on the groundwater. They may supplement or
 replace the groundwater monitoring system. A list of the methods presented and their attributes is
 provided in Table ES-1.

 Systems designed to monitor releases through liners  or provide an early warning of a potential liner
 failure can be divided into two major groups: those that can chemically speciate and quantitate the
 materials that escape (or provide a sample of them for analysis) and those that can only indicate that a
 release is occurring. Examples of the technologies capable of chemical speciation and quantitation are
 lysimeters, diffusion hoses, and soil gas detectors.  Examples of the technologies that simply indicate a
 release is occurring are electrode grids and other electrical methods, electrochemical sensing wire
 cables, time domain reflectometry detection cables, capacitance sensors, and neutron probes. Of these,
 electrochemical sensing wire cables, time domain reflectometry detection cables, and intrinsic fiber optic
 sensors can be constructed so that they react to certain classes of chemicals.

 Most of the monitoring systems listed in Table ES-1  have been deployed at landfills or surface
 impoundments to monitor the unsaturated zone. Each has strengths and weaknesses. Advanced
 tensiometers, lysimeters, electrochemical sensing wire cables, time domain reflectometry detection
 cables, capacitance sensors, and neutron probes mostly monitor the immediate vicinity of the devices.
 Hence, to better detect leaks, they either must be closely spaced, or the unsaturated zone beneath the
containment unit must be engineered to bring the liquid to them. Closely spacing the detectors has the
 advantage of providing a fairly accurate estimate of where a release is occurring, but can be expensive to


                                              iii

-------
deploy and operate. Engineering the unsaturated zone to divert a release to the detectors, can reduce the
number of detectors needed and increase the probability of detecting a release. However, this approach
increases construction costs and reduces the operator's ability to accurately locate the release. Some of
the sites examined in this report have deployed more than one type of detector under a single
containment unit. In these situations, instruments with limited spatial detection capabilities were used at
locations beneath the containment unit considered to be most vulnerable to leaks. For example, suction
lysimeters were placed beneath leachate collection sumps and neutron probe access pipes located at low
points in the primary  or secondary liner system.

Soil gas detectors (diffusion hoses and probes) are relatively easy to deploy, can be automated, and
provide speciation capabilities. For soil gas detectors to be useful, however, the release must contain
volatile constituents. Soil gas detectors have been widely used in the chemical and petroleum industries
for tank and pipeline leak detection and have found some use in monitoring landfills. They can be
deployed before or after construction of a landfill or impoundment. If deployed at a new landfill, it is
possible to greatly reduce the time to detection by including a thin, coarse-grained layer of sand beneath
the bottom of the composite liner to allow for faster diffusion of the escaping volatile organic chemicals.

Some electrical systems for leak detection can only be deployed when the containment unit is built and
remain permanently under the liner or cover. Others can be deployed after construction is complete. The
most widely used electrical system that is deployed under a liner during construction is the electrode
grid. Provided the released material has an effect on the electrical properties of the unsaturated zone
soils, these systems are capable of locating and tracking a release under the landfill with good accuracy.
Electrode grid systems can be automated and, hence, provide frequent checks on the liner's integrity.
However, they do not provide any information on the chemical makeup of the released material. Over
120 electrical grid systems are in use, the majority of which are in Europe.

Electrical systems that can be deployed at a landfill that has already been constructed apply an electrical
potential across the non-conductive geomembrane liner to look for conductive leaks. Though generally
used as a quality assurance method for leak detection in newly constructed landfill liners, these systems
have been applied with some success to operating units. Systems of this type can easily be used to
periodically monitor operating surface impoundments, and there is a well-established commercial
vendor sector offering this service.
                                              IV

-------
Table ES-1. Key Attributes of Vadose Zone Monitoring Systems.













Attribute
Automated
Continuous Operation
Unskilled Operators
Locates Discrete Area of Release
Locates General Area of Release
Determines Volume of Release
Identifies Contaminant
Identifies Chemical Class of
Contaminant
Retrofitted
Commercially Available
Full Scale Deployment for Liners
Demonstration Scale for Liners










c


U
Q
fc"
u
c
o
u

c
'3
o
Q
I
H
^S
^f
*f
*f
*S


*f

P/B
•















Wire Net Design



^j
^f
•





^^r
•
P=Perimeter
B=Beneath liner

-------
VI

-------
                                   CONTENTS

NOTICE AND DISCLAIMER	i

ACKNOWLEDGMENT	i

EXECUTIVE SUMMARY	iii

FIGURES	ix

TABLES  	ix

ACRONYMS	 x

1.0  INTRODUCTION 	 1
     1.1 Objectives .. '.	 1
     1.2 Approach	 1
     1.3 Report Organization	 1

2.0  REGULATORY OVERVIEW OF LINER AND FINAL COVER SYSTEMS	 2

3.0  LINERS  	 5
     3.1 Design	 5
     3.2 Monitoring	 6
     3.3 Technologies  	 6
       3.3.1 Diffusion Hoses	 6
       3.3.2 Intrinsic Fiber Optic Sensors	 7
       3.3.3 Soil Gas		 8
       3.3.4 Electrochemical Sensing Wire Cables  	 9
       3.3.5 Time Domain Reflectometry Detection Cables  	 11
       3.3.6 Electrode Grids 	 12
       3.3.7 Portable Electrical Systems	 15
       3.3.8 Moisture Measuring Devices  	 16
             Capacitance Sensors 	 16
             Lysimeters	 17
             Neutron Probes 	 20
             Advanced Tensiometers 	 21
       3.3.9 Wire Net Designs 	 22
       3.3.10 Cable Network Sensors	 23

4.0  FINAL COVERS	 25
     4.1 Design	'.	 25
       4.1.1 RCRA Subtitle C	 25
       4.1.2 RCRA Subtitle D  	 26
     4.2 Monitoring	 26
     4.3 Leachate Inventory and Survey 	 27
                                        vu

-------
     4.4 Technologies 	  27
       4.4.1 Moisture Measuring Devices  	  28
             Tensiometers	  28
             Time Domain Reflectometry Probes	  29
       4.4.2 Electrode Grids 	  30
       4.4.3 Portable Electrical Systems	  30
       4.4.4 Fiber Optic Stress Gauges	  31
       4.4.5 Fourier Transform Infrared Spectroscopy	  32

5.0  SUMMARY AND DISCUSSION OF FINDINGS  	  34

REFERENCES 	  38

APPENDIX A Glossary 	 A-l

APPENDIX B List of Contacts, Vendors, and Products  	 B-1
                                          vui

-------
                                        FIGURES

1. Typical components of a closed double-lined landfill	  3
2. Minimum design for a hazardous waste landfill liner	  5
3. Minimum design for a MSW landfill liner	  6
4. Diffusion hose detection system	  7
5. Intrinsic fiber optic sensor system	  8
6. Soil gas sampling probe	  9
7. Conceptual model of electrochemical sensing wire cables	  10
8. Conductivity sensing wire	  11
9. Hydrocarbon and solvent sensing wire	  11
10. Time domain reflectometry detection cable	  12
11. Sandy Hill Landfill geophysical electrode grid and borehole installation	  13
12. Cross-sectional view of Sandy Hill Landfill and geophysical electrode grid	  14
13. Sandy Hill Landfill electrical anomaly	  14
14. Portable electrical leak detection system	  16
15. Capacitance sensor  	  17
16. Soilmoisture Model 1920 pressure/vacuum soil water sampler	  18
17. In-plan layout of vadose zone sampling system in California landfill	  19
18. Detail of neutron probe access trench with lysimeter/soil gas conduit for monitoring California
     landfill	  19
19. CAMU vadose zone monitoring system at Sandia National Laboratories	 20
20. Configuration of an advanced tensiometer	 22
21. Layout of wire net design	-. 23
22. Cable network sensor layout	 24
23. Typical Subtitle C cover	 26
24. Typical minimum Subtitle D cover	 26
25. Gage tensiometer	 29
26. Time domain reflectometry probe	 29
27. Monitoring cover using a portable electrical system	:	31
                                        TABLES

ES-l. Key Attributes of Vadose Zone Monitoring Systems  	  v
1.    Key Attributes of Vadose Zone Monitoring Systems  	 37
                                            IX

-------
                                    ACRONYMS
ARAR        applicable or relevant and appropriate requirement
BGS          below ground surface
CAMU        corrective action management unit
CERCLA      Comprehensive Environmental Response, Compensation, and Liability Act of 1980
CCL          compacted clay liner
CFR          Code of Federal Regulations
DoD          Department of Defense
DOE          Department of Energy
ELDS         electronic leak detection system
FS            feasibility study
GC           gas chromatograph
GC/MS        gas chromatograph/mass spectrometer
GM           geomembrane
GPS          global positioning system
HDPE         high-density polyethylene
IFOS          intrinsic fiber optic sensors
IR            infrared
KRC          Karlsruhe Research Center
LCRS         leachate collection and removal system
LDPE         low-density polyethylene
LDS          leachate detection system
LED          light emitting diode
MSW         municipal solid waste
NAS          naval air station
NCP          National Oil and Hazardous Substances Pollution Contingency Plan
OP-FTIR      open-path Fourier transform infrared
PVC          polyvinyl chloride
QA/QC        quality assurance/quality control
RCRA         Resource Conservation and Recovery Act of 1976
SNL          Sandia National Laboratories
UST          underground storage tank

-------
 1.0  INTRODUCTION

 The primary performance goal for waste containment systems is protection of groundwater quality. From
 about the mid-1970s, liners have been used to protect groundwater quality for some types of landfills in
 some parts of the country (EPA, 2002). The integrity of liners and covers for waste containment units is
 typically determined through indirect methods—sampling of downgradient groundwater monitoring
 wells for liners, and the measurement of changes in leachate levels occurring after closure for covers.
 This report documents technologies that can be used to detect releases through liners more directly as
 well as technologies that can detect changes in cover integrity before large amounts of water enter a
 closed landfill.

 1.1 Objectives

 The objectives of this report are:

 •    Identify and describe current technologies that could be used to detect releases to the vadose zone
     beneath the liner of a containment unit.
 •    Identify and describe technologies that could be used to identify potential problems with the
     integrity of final covers.
 •    Present examples of where these technologies have been deployed.
 •    Provide sufficient information on these technologies to provide some preliminary assessment on
     technology applicability.

 1.2 Approach

 The information on liner and cover monitoring technologies was gathered by conducting a
 comprehensive literature search and reviewing vendor websites that feature leak detection equipment.
 Both existing and potential leak detection technologies were evaluated for their applicability to vadose
 zone and final cover monitoring.

 1.3 Report Organization

 This report is divided into four sections.

 •    Section 1.0, Introduction, describes the content of the report.
 •    Section 2.0, Overview of Liner and Final Cover Systems, explains the regulations governing the
     standard design of liners and covers and summarizes design requirements.
 •    Section 3.0, Liners, discusses the design and monitoring requirements for liners and describes the
     current industry practice. This is followed by a summary of technologies that can be used to
     monitor the performance of liner systems.
 •    Section 4.0, Final Covers, discusses the design and monitoring requirements for covers and
     describes the current industry practice. This is followed by a summary of technologies that can be
     used to monitor the performance of cover systems.
A list of references relevant to this report follows, as do two appendices:
     •    Appendix A, a glossary of technical terms used in the report.
     •    Appendix B, a list of vendors organized by technology.

-------
2.0  REGULATORY OVERVIEW OF LINER AND FINAL COVER
      SYSTEMS

The need for liner and cover systems at landfills is driven in large part by the need to contain
contaminated liquids (leachate) and gases generated within a landfill. Containment prevents the
migration of leachate and gases to soil, groundwater, surface water, and air outside the landfill. Leachate
is generated when liquids are disposed of directly in the waste pile, when rainfall accumulates in the
landfill before placement of a final cover, or when there is a flaw in the final cover that allows water to
penetrate it. Landfill gases are generated as organic wastes biodegrade. Biodegradation primarily
produces methane and carbon dioxide, but these gases can also contain small amounts of chlorinated and
non-chlorinated volatile solvents. Volatile organic vapors also can be produced when they partition from
the dissolved phase of a leachate.

The Resource Conservation and Recovery Act of 1976 (RCRA) and subsequent amendments gave the
Environmental Protection Agency the authority to regulate the design of hazardous waste landfills and
impoundments as well as municipal solid waste (MSW) landfills. RCRA Subtitle C regulations
governing the design of engineered liners and covers for hazardous waste landfills and surface
impoundments were issued in 1982. These regulations were performance based and required installation
of a double liner system and a cover having a permeability equal to or less than that of the liner. The
goal of RCRA Subtitle C was to ensure that the primary liner and leachate collection system (for
landfills) collect and treat any liquids that enter a containment unit.

In 1991, RCRA Subtitle D regulations covering the design of engineered liners and covers for MSW
landfills were issued. These regulations were also performance based and specified a single, composite
liner construction (or its equivalent) and a cover having a permeability of 10~5 cm/s or less or less than or
equal  to the liner system. Composite liners are constructed using a geomembrane material overlying
compacted soil. Final cover systems can vary widely but are typically composite systems similar in
design to single liners. Figure 1 shows many of the components of an engineered containment system.

The performance standards for liners and covers are discussed in Sections 3 and 4 of this report,
respectively. State requirements generally mirror the federal performance standards. Currently 49 of 50
states  have delegated MSW landfill programs (EPA, 2002).

Remedial actions carried out under the Comprehensive Environmental Response, Compensation, and
Liability Act of 1980 (CERCLA) and subsequent amendments can include capping of hazardous wastes
in place, constructing a landfill to contain wastes from a cleanup, or constructing a treatment facility,
such as an impoundment or leach pad. The National Oil and Hazardous Substances Pollution
Contingency Plan (NCP) that implements CERCLA requires that remedial actions must at least attain
applicable or relevant and appropriate requirements (ARARs). This means that before remedial or
removal actions can occur at a CERCLA site, EPA must determine what other federal, state, and local
regulations apply—either directly (applicable) or indirectly (relevant and appropriate)—to the action
(EPA, 1989b). RCRA Subtitle C requirements for treatment, storage, and disposal facilities will
frequently be ARARs for CERCLA actions because RCRA regulates the same or similar wastes as those
found at CERCLA sites.

-------
                                                               Gas
                                                        Collection and Removal
                                                             System
                                                             j_l__C-
                                                            To Treatment
                       Surface-Water
                    Management System
                     To Treatment
                            Leachate Collection
                                  and
                             Removal System
                                               Leakage         T
                                            Detection System  _   '  .      Composite
                                                          Double Liner    Bottom Liner1
                                                            System
  Figure 1. Typical components of a closed double-lined landfill.
                                                                                   Source: EPA, 2002.
The current regulations, with some exceptions among state regulations, do not call for directly
monitoring the integrity of all landfill components or impoundment containment systems. For example,
the long-term performance of covers is determined by observing the level of leachate that is produced in
a landfill cell. Leachate levels after closure generally fall to a negligible level within 10 years, or less,
following capping (EPA, 2002). If leachate levels do not exhibit a downward trend with time, then it can
be assumed that the integrity of the cover has been compromised.

In double-lined landfill cells, the second liner with attendant leachate collection system acts as a leak
detection system for the first liner. However, with the exception of some state regulations, there is no
requirement to monitor directly under the bottom-most liner of single- and double-lined designs. The
accepted practice for monitoring the performance of liner systems is to install groundwater monitoring
wells at the downgradient edge of a containment unit that are screened within the uppermost aquifer and
look for changes in groundwater quality that might indicate a release is occurring.

The primary alternative to groundwater monitoring is to measure vapors and liquids in the unsaturated
zone beneath a containment structure or vapors at its perimeter. There are many technologies available
for monitoring the vadose zone beneath a containment unit. The choice of which one to use or which
ones to use in conjunction with each other is site specific. Some considerations in making this choice
are:

•     Will the containment unit require retrofitting?
•     Will the monitoring strategy cover the entire subsurface beneath the bottom liner, or will it
      monitor the most vulnerable areas, such as where it is difficult to obtain competent geomembrane
      seals (e.g., around high-flow leachate collection channels and sumps)?

-------
•    Does the system continue to produce good results after a leak is detected and repaired?
•    Is it necessary to identify chemical species, or is it sufficient to simply know that a release is
     occurring?
•    How accurate must the monitoring system be in locating the point of the release?
•    What is the service life and reliability of the monitoring devices, and how easy are they to replace
     if they fail?
•    Does the monitoring system need to operate continuously?

Several states (e.g., Arizona, New Mexico, Oregon, and Washington) allow alternatives to monitoring
wells for measuring the performance of liner systems. Alternative methods are generally allowed when
the methods can be shown to be more cost effective than monitoring wells which is generally the case
when the depth to groundwater is large. The State of California requires that alternative methods be used
in conjunction with monitoring wells.

-------
3.0  LINERS
A liner system functions to intercept leachate or gas migrating within a landfill and route it to a
collection point where it can be removed or treated. With impoundments it prevents the escape of the
unit's contents. For optimum long-term performance, the liner must be physically resistant to the
concentrations of chemicals expected in the leachate for as long as leachate is generated in the unit.

Landfill and impoundment liners typically include a composite liner component. Composite liners are
constructed using a geomembrane (GM) overlying compacted soil to achieve a specified minimum
hydraulic conductivity. Large sheets of geomembrane must be seamed together to completely cover the
landfill bottom and sides. Commonly used geomembrane materials include:

•    high-density polyethylene (HDPE);
•    very flexible polyethylene;
•    polyvinyl chloride (PVC);
•    flexible polypropylene; and
•    ethylene propylene diene monomer (EPA, 2002).

3.1 Design

A double-liner system with leachate collection and removal capabilities above each liner is required for
Subtitle C landfill units. 40 CFR 264.301 suggests that the top (or primary) liner consist of a
geomembrane and the bottom (or secondary) liner be a composite, with a geomembrane overlying at
least 90 cm of compacted clay  (CCL) or compacted soil (Figure 2). The soil must have a hydraulic
conductivity of no more than IxlO"7 cm/s. In practice, a landfill owner/operator has a wide choice of
construction techniques and materials to choose from to meet these performance criteria.

The primary leachate collection and removal
system (LCRS), which is situated above the
primary liner, is designed to maintain leachate
levels at 30 cm (1 ft) or less and to convey the
leachate to a sump where it is pumped to a
holding tank or treatment system. The leachate
detection system (LDS) below  the primary liner,
is a secondary leachate collection system that
detects leaks through the primary liner.
Impoundment design (40 CFR  264.221) is
similar to landfills but lacks the LCRS section.
Subtitle D requirements for MSW landfills are
somewhat less stringent than Subtitle C units.
Subtitle D requires a composite liner with a
leachate collection system capable of
maintaining the leachate at a depth of 30 cm or
less. Subtitle D requirements for MSW landfills
are somewhat less stringent than Subtitle C
units.

0.9 m^ >>>>>>>/>V
                                                  v  x/xxxx^xxx/xxx/xxx
                               GM
                               (primary liner)

                               GM
                               (secondary liner]

                               Composite
                               secondary
                               liner
Figure 2. Minimum design for a hazardous
waste landfill liner.

                                Source: EPA, 2002.

-------
                                  GM
                                  Composite
  Figure 3. Minimum design for a MSW landfill
  liner.

                                 Source: EPA, 2002.
Subtitle D requires a composite liner with a
leachate collection system capable of maintaining
the leachate at a depth of 30 cm or less. The liner
must consist of a minimum 30-mil flexible
membrane liner (60 mil if the liner is HDPE)
overlying not less than 60 cm of compacted soil
with a hydraulic conductivity of no greater than
IxlO"7 cm/s. A different design may be used if the
liner is found to be protective by the state's
program director. Figure 3 shows a typical Subtitle
D liner system, which consists from top to bottom
of filter material, LCRS, and a composite liner.
Some states have adopted more stringent
requirements for their MSW landfills.
3.2 Monitoring

The monitoring and inspection requirements of 40 CFR 264.303 (Subtitle C liners) include weekly
inspections for the presence of leachate in the two leachate collection systems—the LCRS and the LDS.
The amount of liquid removed from the LDS must be recorded weekly for both the active life and
closure period of the landfill or impoundment. Depending upon the performance of the liner system, the
weekly requirement can be relaxed to longer intervals (e.g., monthly, quarterly, or semi-annually). Sub-
tide D requires leachate removal and treatment when necessary to maintain head limitations, but does
not require leachate monitoring. Both subtitles require a groundwater monitoring system to detect
changes in water quality that may be related to a release.

3.3 Technologies

The literature research conducted for this report identified 13 technologies that either have been used to
monitor the vadose zone beneath a liner or have the potential to do so. While three technologies were
specifically intended for vadose zone containment monitoring, the remainder were designed for leak
detection or moisture measurements in other industries (petroleum, chemical, agricultural, geological
exploration). The technologies are not necessarily deployed in the same fashion, nor do they detect or
measure the same aspects of a release.

3.3.1 Diffusion Hoses

Diffusion hose systems consist of a collection hose, pump, and detector. The collection hose is
permeable to the chemical being monitored. When a release occurs, the chemical, which must have some
volatility, diffuses into the air space in the hose. The pump pulls air through the hose and past the
detector. Since the velocity of the carrier gas can be calculated, the location of the leak can be
determined using the arrival time of the detected contaminant. Diffusion hose systems can be
constructed directly under a geomembrane liner. In double-liner systems, they can be placed both above
and below the bottom liner, allowing leak locations to be determined in both liners.

-------
 Status. Diffusion hoses have been deployed at a number of petroleum and chemical facilities to detect
 releases from product pipelines and tanks as well as at several landfills in Europe.

 General Attributes. Diffusion hose systems can be automated and set up to sound an alarm that a
 volatile substance is present in the collection hose or the hose can be connected to a gas chromatograph
 for contaminant identification. For best results, the system should be deployed beneath the liner during
 construction. Unless perimeter monitoring for soil gas monitoring is acceptable, the system would be
 difficult to construct under an existing unit. The equipment associated with diffusion hose systems is
 relatively rugged and can be easily replaced if needed.
Examples. An example of a
diffusion hose system is the
Siemens LEGS leak detection
system, which has been deployed
at several landfills in Germany
(Siemens, 1998). The system
consists of a permeable low-
density polyethylene (LDPE)
tube that fits around a perforated
stiff core to provide strength
(Figure 4). The LDPE tube is
pressure tight at installation so
air can only enter at the opening
of the tube during purging.
During a purge cycle, a pump
pulls the contents of the tube
through a detector that provides
total concentrations and displays
them in a format similar to a gas
chromatogram. Before a purge
cycle begins, an electrolytic cell
injects a specific volume of test
gas into the end of the tube. This
gas acts as a marker and its
appearance at the detector indicates that the entire tube has been purged. Based on the ratio of the travel
time of the leak peak to the marker peak, the leak location can be calculated.

3.3.2 Intrinsic Fiber Optic Sensors (IFOS)

The IFOS are deployed in dry wells beneath or beside the containment unit. IFOS typically consist of a
cladded optical fiber that has had part of the cladding replaced with a chemically selective layer (Figure
5). The index of refraction of the chemically sensitive layer changes in direct proportion to the
concentration of chemicals in the air or water that comes in contact with it. As a chemical partitions into
the layer, which selectively and reversibly adsorbs it, the change in the effective index of refraction is
determined by measuring the amount of light transmitted through the optical fiber. The response is
directly proportional to the concentration of the chemical(s) present. IFOS can detect chemicals (or
classes of chemicals) of interest in the parts per million (ppm) range, which may be too high for some
landfill vadose zone applications.
Figure 4. Diffusion hose detection system.
                                             Courtesy: Siemens.

-------
Status. The most prevalent use of intrinsic fiber optic sensors (IFOS) is in the petroleum and chemical
manufacturing industries.
General Attributes. IFOS systems are generally
automated and alarmed. In a hazardous waste
impoundment where the contents are known,
the chemically sensitive layer is chosen to
match the chemical of concern. Deciding which
chemicals or class of chemicals to monitor in a
landfill with uncertain contents is more
difficult. An operation and maintenance
drawback of using IFOS at landfills is that the
number of reversible reactions that include the
adsorption and subsequent desorption of
chemicals is limited; therefore, probes may
have to be regenerated after extended use. The
method of deployment makes retrieval and
replacement of IFOS relatively easy.

Examples. No examples of IFOS deployment at
landfill or impoundment units were identified.
Figure 5. Intrinsic fiber optic sensor system.
                                                                            Courtesy: DecisionLJnk.
3.3.3 Soil Gas

Soil gas detection systems rely on the movement of volatile chemicals through the vadose zone and into
a collection system. These volatile chemicals can originate from vapors diffusing through the liner or as
part of escaping leachate in which they are dissolved. The collection system can be active or passive.

Passive systems: There are two basic designs of passive soil gas systems. In the first design, a collector
(typically an activated carbon ribbon or other sorbent material) is placed in a container that is closed at
the top and open at the bottom. This container is then suspended in a dry well for a set period of time.
After retrieving the container, the sorbent material is purged of the sorbed chemicals, which are analyzed
using a gas chromatograph/mass spectrometer (GC/MS). In the second design, the collector is placed in
a hydrophobic, gas-permeable material and suspended in the dry well. After a set period of time, it is
collected and the sorbed chemicals are purged and measured with a GC/MS. A more recent modification
of the passive system involves the use of fiber optic sensors that are placed in a probe or dry well where
they periodically test the ambient gas  for contaminants.

Active systems: In an active soil gas system, a collection tube and/or probe are placed in a dry well and
soil gas samples are removed under vacuum. Figure 6 shows a horizontally deployed,  slotted conduit
with varying lengths of probe-tipped tubing inside. The probes are placed at pre-determined distances in
the conduit and sampled from a central sampling station. Deployment of soil gas systems in dry wells or
horizontal screens should perform well, even in fine-grained soil, because the systems measure
equilibration concentrations of well air with soil gas. However, the time from release to detection will be
longer in fine-grained soils than in coarse-grained soils, and preferential channeling can defeat the
system.
                                              8

-------
Status. Soil gas systems have been used primarily for characterizing hazardous waste sites and for
detecting leaks in petroleum and chemical storage tanks. There are approximately 100 different soil gas
sampling systems in existence (Looney and Falta, 2002).
                                                      Slotted Conduit
Sample Port
 Protector
                                                                                 Waterproof
                                                                                 Membrane
General Attributes. Measurement of soil gas
vapors is generally done by collecting samples
from perforated piping placed under the landfill
or from vertical dry wells placed at its perimeter.
Generally, for large landfills, perimeter dry wells
will not be able to detect leaks in a timely
fashion. Lateral piping placed under the bottom
liner should be designed similarly to the leachate
collection piping in the landfill liner so that it
can withstand landfill loading. The effectiveness
of the soil gas monitoring system can be
improved if the dry wells or perforated piping
are emplaced with a layer of coarse-grained sand
to facilitate vapor movement.

Soil gas monitoring systems are generally easy to
install and are accessible for repair and
maintenance. Active systems can be  automated
and connected to total detectors, GC, or GC/MS
units for speciation and quantitation. Operation of a total detection system requires minimal training,
while GC/MS operation require a trained operator. The ability to detect and locate a release depends
upon the spatial distribution of the dry wells and/or horizontally laid screens. The systems only detect
volatile organic compounds, but generally have sufficiently low detection limits to detect the low levels
found in MSW landfill leachates.
                                                 Figure 6. Soil gas sampling probe.
                                                                           Courtesy: Tracer Research Crap.
Examples. Soil gas monitoring systems in perimeter vertical dry wells have been used in California for
containment units that were not constructed with vadose zone monitoring systems. They have also been
used where groundwater is deep and monitoring wells are not likely to provide a good first warning
system. For example, deep groundwater at the Kettleman Hills California hazardous waste facility
necessitated the use of perimeter vertical dry wells. The dry wells are periodically sampled using a
portable GC, that can identify the presence of volatile organics with parts per billion detection limits. If
chemicals are found, the dry well can be immediately resampled for offsite analysis.

Several gold beneficiation facilities in California also use lateral, perforated, PVC pipe under
containment units to monitor for cyanide releases. Soil vapors are pumped under vacuum out of the pipe
and through a Draeger tube that tests for cyanide gas. The Draeger tube detection limit is in the 2 to 15
mg/m3 range. This deployment could conceivably be used in conjunction with GC or GC/MS equipment
for monitoring multipurpose units.

3.3.4 Electrochemical Sensing Wire Cables

Electrochemical sensing wire cables all function on the same general principle. The cable contains at
least two circuit loops — one of which carries an impressed current (continuity circuit), and the other is
connected to an alarm. A leak is detected when the circuits are shorted (Figure 7), which can be caused

-------
                             With Leak
Figure 7. Conceptual model of electrochemical
sensing wire cables.
                                     Courtesy: Raychem Corp.
by several mechanisms, depending on the
cables used. For example, the short can
occur when a leak of conductive fluid
facilitates current flow between the cables
(Figure 8). Shorting can also occur by
direct wire contact. Direct wire contact
results when the material separating the
wires degrades allowing the wires to
touch. Finally, the short can occur when
an outer coating of the cables swells when
brought into contact with the leak (Figure
9). The swelling forces the two wires
together to complete the alarm circuit.

When small areas are being monitored, the
system is usually set up to sound an alarm.
When the monitored area is large,
hardware is added that can also calculate
the point of the voltage drop in the
continuity line—thus, pinpointing the
position of the leak. Conductive fluid
cables generally can be dried and reused, while the swelling and degradation types must be replaced.

Status. Electrochemical sensing wire cables were originally designed to detect releases from product
pipelines and storage tanks. Then- primary market has been the petroleum and chemical industry, though
the cables can generally be modified to detect water.

General Attributes. The various types of electrochemical sensing wire cables are all automated and
require minimum maintenance and operator experience. When installed during the initial construction of
a containment unit, the cables can be installed within a drainage layer. While this increases the cost of the
monitoring system, it also improves its ability to locate a release. When the monitoring system is
deployed as a retrofit, it can only monitor the area that drains to the cables. If the overlying soil is fine-
grained, then  wicking away from the cable's more permeable zone might delay the detection of a leak for
some time. For access and operation and maintenance, the cables would have to be deployed in protective
perforated piping.

Examples. No examples of electrochemical sensing wire cable deployment at landfill or impoundment
containment units were identified.
    10

-------
        Continuity \
        wire (red)!
Fiuoropolymer
carrier
       Signal wire i   \ Sensing wires
         (yellow) j   ! (black)
Continuity
wire (red)
) Fiuoropolymer
1 carrier
0.92 in.
(23 mm)
              Sensing   ^\iK   Sensing
                 wire —»pc£— wire
               (black)    VW--'   (black)

                Signal wire i
                   (yellow) 1
                                                         1
  Figure 8. Conductivity sensing wire.
                                        T
                                  Drawing not to scale
                                                                                 Courtesy: Raychem Crap.
           Fiuoropolymer braid
  0.27 in.
  (6.9 mm)
        Conductive polymer jacket
         Continuity wire (red)
         {   Spacer wire (white)

             Signal wire (yellow)
            ! Sensing wire (black)
                                                                        0.52 in.
                                                                        (13 mm)
  Figure 9. Hydrocarbon and solvent sensing wire.
                                                                                 Courtesy: Raychem Corp.
3.3.5 Time Domain Reflectometry Detection Cables


Time domain reflectometry measures an electromagnetic pulse sent down a coaxial cable to detect an
impedance change or discontinuity. The electromagnetic pulse travels down the cable until a change in
impedance is encountered. When this happens, part of the wave is reflected, and instrumentation at the
input area measures the time it takes for the reflection (or echo) to reach a receiver. The measured time is
used to compute the distance to the impedance change. Impedance changes can be caused by a number of
physical changes in the cable. For chemical release detection cables, the change is generally caused when
the impedance fluid (air) is replaced by a fluid having a different impedance, such as leachate, solvent, or
contaminated air.


Status. Time domain reflectometry has been used extensively in the telecommunications industry for
testing continuity in cable systems and for detecting unauthorized access to these systems. It is also used
in the petroleum and chemical industries to detect releases of product.


General Attributes. Time domain reflectometry is an automated detection system that is easy to install
and requires little operator training. When installed during the construction of a containment unit, it can
be placed within a drainage layer. While this increases the cost of the system, it also improves its ability
                                                11

-------
 to locate the release. When the monitoring system is deployed as a retrofit, it can only monitor the area
 that drains to the cables, unless volatile organics are present. If volatile organics are present, the change in
 gas impedance might be sufficient to trigger a response from the system. If the source of the release is
 repaired, cables can be dried and reused. Because of loading from the landfill waste and maintenance
 concerns, the cables need to be placed in protective piping.

 Examples. Although originally designed for use in the petroleum and chemical industries, Perma-Pipe,
 Inc., offers a product line called "PermAlert" that has been used for (1) monitoring miles of hazardous
 waste pipeline at the Department of Energy's Hanford Reservation; (2) vadose zone leak detection under
 double-lined impoundments (e.g., acid ponds); and  (3) for monitoring piping that carry leachate from
 landfills to a treatment system or holding impoundment. PermAlert has both wicking and non-wicking
 leak detection cables that are coated with polymers and are designed to detect water-based chemicals
 and/or hydrocarbon liquids. Time domain reflectometry sensing cables are constructed with an open
 architecture coaxial cable (Figure 10). A protective, permeable, nonconductive cover surrounds a wire
 mesh that is separated by an air pocket from a
 polymer coated copper wire. After installation,
 the cable has a characteristic impedance
 between the wire mesh and the copper wire.
 Any changes to this impedance brought about
 by breaks or intrusion  into the cable, or as is
 the case of the PermAlert, by the replacement
 of the interstitial air by a fluid, can be detected
 using standard time domain reflectometry            **««•/ **•  1^1
 .  .       . ..                                      nw*W**JwiO
 instrumentation.

 3.3.6 Electrode Grids

 Electrode grids can be used to test for liner
 flaws immediately after construction and to
 conduct long-term performance monitoring at a
 containment unit. During construction of the containment unit, individual electrodes are placed in a
 conductive layer beneath the lower geomembrane liner and compacted soil layer. The electrodes are
 connected to one of a number of multicore cables that run to a central processor. A source electrode is
 placed in the protective sand overlying the geomembrane liner. Electrode grids can be configured to
 measure the electrical potential caused by electrical  current flowing through leaks or to measure changes
 in the localized resistivity of the conductive layer caused by fluids flowing through the leaks.

 Status. Electrode grids were designed specifically for landfill vadose zone monitoring. As of 1999, over
 120 of the electrode grid-type systems had been installed, mostly in Europe (Peggs, 1999).

 General Attributes. An electrode grid system can only be installed during the initial construction of the
 unit. It uses simple, durable parts. Electrodes made of high-grade, stainless steel alloy or non-corrosive,
 liner compatible conductive HOPE are less likely to fail before the design life of the facility. Electrode
 grid systems cover the entire area beneath a containment unit and can be used to both identify releases and
 track their migration in the subsurface. These systems can be continuous and require a trained operator.

Examples. An electrode grid system was deployed in 1995 at the Sandy Hill Landfill in the United
 Kingdom. A simple mathematical model and small-scale testing were used to determine the electrode
:igure 10. Time domain reflectometry detection
cable.

                                  Courtesy: Penna-Hpe, Inc
 12

-------
spacing, which consists of parallel lines of electrodes spaced 20 m apart. Spacing between electrodes
within a given line alternates between a line on 20-m centers and a line on 10-m centers (Figure 11). The
316 stainless steel electrodes were placed in the base of a 300-mm-thick, bentonite-enhanced sand that
makes up the bottom layer of the composite liner. A 2.5-mm thick HDPE liner overlies the bentonite-
enhanced sand and is covered by a 500-mm layer of protective sand (Figure 12). The electrodes are
connected by multicore cables that lead to a portable computer for processing data and a Campus Geopulse
earth resistance meter. The liner was tested using the electrode system prior to accepting waste in the
landfill. The test revealed an anomaly within one of the 20-m grid squares (Figure 13). Testing with a
hand-held voltmeter located the anomaly within 2 cm, and the soil cover was removed to reveal two knife
cuts. As the landfill accepted waste, the protective sand layer was applied higher and higher on the berm
sides. The sand layer provided a conductive material that allowed the liner on the upper portions of the
berm to be tested. Tests revealed two more holes. Testing of the 3-hectare cell takes approximately 1 to 2
hours. For more information, see White and Barker, 1997.
                                  Get! 2 to be lined
                           Geophysical System Installed
                              During Summer of 1998
                                                                         Electrode Position
                                                                         on Geophysical Grid
                                                                     General direction of
                                                                     dip of the WHdinoofB
                                                                      Sandstone (0-10)
 Figure 11. Sandy Hill Landfill geophysical electrode grid and borehole installation.

                                                     Reprinted from Ground Water Monitoring & Remediation with permission
                                                      of the National Ground Water Association. Copyright 1997.
                                                 13

-------
  Existing sandstone
       quarry
r Insulating 2.5mm high-density
! polyethylene liner
                                                                                       Sandstone
                                              • Grid of monitoring
                                              electrodes
                                    20m
                           L Bentonita enhanced sand
  Figure 12. Cross-sectional view of Sandy Hill Landfill and geophysical electrode grid.
                                                      Reprinted from Ground Water Monitoring & Remediation with permission
                                                        of the National Ground Water Association. Copyright 1997.
The system can detect a release from the overlying liner and track the progress of the leachate plume as it
moves through the soil beneath the liner. Resistivity data were collected and archived before the landfill
began operating. These data are compared to resistivity data measured during landfill operation to identify
any substantial changes that would
indicate a release.

Welsh Engineering Science &
Technology, Inc. (now SRK Consulting)
developed and patented an electrode grid
called the Electronic Leak Detection
System (ELDS) for detecting leaks below
heap leaching containment units used in
the gold mining industry. The first
deployment of ELDS occurred in 1987,
and at least 12 have been deployed since.
The company, G2 Imaging, installed
ELDS under a leach pad liner in northern
Nevada. The system consists of 147
stainless steel  electrodes placed in a
rectangular grid beneath the liner. Two
PVC pipes also were installed to calibrate
the system by  injecting a salt solution.
The system, which consisted of an array
of 215 monitoring points, was able to
detect a hole that was purposely placed in
the liner as a test.

After ore was placed on the leach pad
and the leaching process began, the
              3951 OO.OO   395140.00  39518O.OO  395220.OO  395260.00
                Units are volts/amps

      Figure 13. Sandy Hill Landfill electrical anomaly.
                    Reprinted from Ground Water Monitoring & Review with permission
                         of the National Ground Water Association. Copyright 1997.
                                                 14

-------
 system was monitored biweekly using an Ms Instruments Syscal Junior resistivity meter. ELDS software
 downloaded the data from the receiver and produced contour and three-dimensional surface plots of the
 data. The ELDS detected four separate leak locations. Each location was excavated and the holes were
 repaired; however, upon rewetting, the system again indicated leaks in the same areas as before. A more
 careful check of the excavated areas revealed additional holes. After these repairs, the response of the
 ELDS to the gradual drying of the soil beneath the liner indicated the liner was effectively repaired.

 3.3.7 Portable Electrical Systems

 The portable electrical system involves transmitting an electrical current from an electrode in a conductive
 medium above the geomembrane liner. A second electrode is placed in the material (which must be
 conductive) below the primary geomembrane liner in a double liner system, or in the case of a single liner,
 grounded at the containment unit perimeter. When a current is applied to the first electrode, current leaks
 through any breaks in the liner. The leakage is detected by gridding the surface and conducting a survey
 with a hand held probe and digital recorder. The probe can locate the release with excellent accuracy. Use
 of this system is generally limited to construction quality assurance in landfill operations because the
 probe is sensitive to the vertical distance from the release area. While there have been some investigators
 who report leak identification in fill up to 15-20 feet in depth (Peggs, 2001a), this system should not be
 thought of as a long-term landfill monitoring method. Surface impoundments, on the other hand, can be
 periodically drained to make them wadeable or the probe can be towed across the bottom by a boat.

 Status. The portable electrical system (Figure  14) was commercialized in 1985 and has been used at
 hundreds of sites (Coluci et al.,_ 1996, and Darilek and Lane, 1999). The system was developed as a quality
 assurance measure for testing newly installed liners at landfills and impoundments, but it can also be used
 for long-term monitoring at surface impoundments. More than 20 companies worldwide offer these
 systems.

 General Attributes. Portable electrical systems are well understood among geophysicists. They are easy to
 install or retrofit.

Examples. The Electrical Leak Imaging and Monitoring System developed by Leak Location Services,
Inc. was used to locate a leak at a hazardous waste landfill that accepted stabilized treatment residues and
soils. Two 80-mm long cuts  were found under 3 m of waste and were subsequently repaired by the
owner/operator. The system  used a generating electrode in the leak detection layer with a sink electrode
located in the waste. In a variation of the normal survey technique, a reference electrode was also placed in
the waste and the gridded survey potentials were compared to it using a mathematical algorithm (Laine,
Binley, and Darilek, 1997a and 1997b) .

No examples of this system being  used for long-term performance monitoring were identified.
                                               15

-------
                                                             Current
                                                            electrode
       Receiving electrode
                   Electrical current
                  passed into landfill
                                                                            Synthetic
                                                                              liner
                                                                             (HOPE)
               Current flow
              through defect
                  (miner
  Figure 14. Portable electrical leak detection system.
Sandstone aquifer
                                                    Adapted from Ground Water Monitoring & Remediation with permission
                                                            of the National Ground Water Association. Copyright 1997.
3.3.8 Moisture Measuring Devices

There are a number of moisture measuring devices that either directly or indirectly measure soil moisture
content or soil water potential. Many of these devices have been thoroughly tested in other applications;
some were developed for agricultural applications, while others are traditional borehole geophysical
techniques used in geological exploration. The summary of devices below (capacitance sensors,
lysimeters, neutron probes, and advanced tensiometers) is not meant to be comprehensive. It includes only
those techniques that have actually been deployed (primarily in California) to measure vadose zone
moisture beneath a landfill.

Moisture monitoring devices are widely available, generally easy to install, and most do not require highly
skilled operators. Although some can be retrofitted after a containment unit is constructed, it is best to
install them during construction. The devices typically only measure moisture content in a small area
around them or require direct contact with percolating water.

Capacitance Sensors

Capacitance sensors use frequency domain induced polarization to measure the dielectric of the soil
around them. The dielectric properties of soil are primarily related to its water content but also could be
affected by the ionic content of the water. The dielectric of dry soil is approximately 5, and the dielectric
of water is approximately 80.  When soil becomes moistened by a leak, its dielectric increases. Measuring
the dielectric  over time will reveal whether the soil is becoming wetter or drier. The sensors are calibrated
and implanted in the ground at the desired depth. They can be permanently or temporarily installed.
                                                16

-------
                                           51 mm
                    -261 mm-
Figure 15. Capacitance sensor.
Status. The primary use for capacitance sensors is the measurement of field moisture in agricultural
applications, although they also have been used in construction applications.

General Attributes. Capacitance sensors must make good contact with the surrounding soil. As a result,
they may be difficult to install in some soils. Capacitance sensors can be operated continuously, need
relatively unskilled operators, and provide accurate values for soil moisture. As the soil moisture increases
however, their accuracy decreases. Their long-term reliability and ability to maintain calibration is
uncertain, especially in water with varying ionic concentrations (U.S. EPA, 1993b).

Examples. Troxler Electronic Laboratories, Inc., produces the Sentry 200 series of capacitance sensors for
use with environmental moisture monitoring systems. A Sentry 200 system was installed at the San
Marcos Landfill in San Diego, California, in 1995. The system contains sixty probes and eight monitoring
units. Each probe measures the dielectric
of approximately 1.5 liters of soil
surrounding it. The probes are 261-mm
long, 51-mm wide, and weigh 3.6 kg
(Figure 15). They can operate in
temperatures ranging from 0-70°C. The
outside of the probe is constructed of
stainless steel, HDPE, and fiberglass
filament making it resistant to corrosion
and breakage. The probes are connected
to the monitoring units by coaxial cable.
The personal computer, which has
downloading capabilities, can be run on
DC or AC power. The total cost of the
project, including equipment,
engineering, and installation, was $219,000. The system automatically measures moisture levels four
times per day, and the data are down-loaded biweekly. Performance has been good except compression
pressures from the overlying fill have broken the wiring connections to several of the capacitors.

Lysimeters

Suction lysimeters are used to sample soil pore water, which is generally under negative pressure (non-
flowing). In addition to being capable of obtaining water samples, suction lysimeters can be used to
evaluate whether soil is gaining or losing moisture. Typically, suction lysimeters are constructed of a
porous ceramic bulb and a cylindrical reservoir to store the water. For shallow applications, they are
usually equipped with a tube that extends to the surface. A vacuum is applied to this tube to draw water
through the bulb, into the reservoir, and to the surface. For use at lengths or depths greater than 4.5-6 m,
suction lysimeters can be equipped with two tubes. The two-tube arrangement allows for a vacuum to be
applied to draw water into the reservoir, followed by air pressure to transport it to the surface. To function
properly, a good hydraulic connection between the ceramic bulb and the surrounding soil must be
established—usually by placing the bulb in a layer of silica flour during installation (Figure 16).

Plate/pan lysimeters are covered containers that collect water that percolates through the vadose zone and
comes  in contact with the permeable covers. The container is connected to a tube that leads to a sampling
point on the surface. The water is generally withdrawn from the container by pumping.
                           Courtesy: Troxler Electronic Laboratories, Inc.
      17

-------
     Silica'
      Flour
Ceramic Cup •""
  Figure 16. Soilmoisture Model 1920
  pressure/vacuum soil water sampler.

                   Courtesy: Soilmoisture Equipment Corporation.
Status. Lysimeters are primarily used in
agricultural and forestry applications. There are
two basic designs: those that sample soil moisture
in unsaturated conditions (e.g., suction
lysimeters) and those that sample in saturated
flow conditions (e.g., plate lysimeters).

General Attributes. Lysimeters have a limited
range of influence and should be placed in areas
most likely to experience a release, such as under
pump sumps. Because they are very difficult to
retrofit, lysimeters ideally should be installed
during landfill construction. While the required
operator skill is minimal, lysimeters are generally
not automated, so sample collection can be time
consuming. Typically, the volume of the water
sample collected is not large, which limits the
number of chemical analyses that can be
performed. In addition, the ceramic cup is subject to mineralization and clogging, and depending on the
installation technique used, the suction lysimeter may not be retrievable.

Examples.  A redundant vadose zone system that included pressure/vacuum suction lysimeters, gypsum
blocks, neutron probe tubes, and soil gas sampling points was installed at a landfill in California (Cullen et
al., 1994). The gypsum blocks were used to monitor potential problems at the seam joints along Module HI
(Figure 17), and were not intended for long-term monitoring. The design of the monitoring system also
included a neutron probe access tube that extended under and down the center of each of the three new
cells. The leachate collection system of each cell drained to the center of the cell and then to a sump. The
trench in which the neutron probe access tube was installed also housed the soil gas and lysimeter
sampling tubes (Figure 18). Horizontal soil gas wells were placed at equal alternating intervals, 38 m apart
along the trench. The wells consisted of a 15.25-m long horizontal trench placed just under the compacted
clay of the composite liner. Within each trench, five sections of alternating schedule 80 PVC casing blanks
and screens (20-slot) were installed and surrounded with drainage gravel. The sampling tubes for the soil
gas samplers in these dry wells were routed to the neutron probe trench and then routed to a sampling
station outside the containment module wall. The soil gas was drawn  from each sampling station and
tested with a portable GC.

Lysimeter placement at the landfill was based on an evaluation of the subsurface soil beneath the modules.
Cullen et al., recommended placing pressure vacuum lysimeters in areas most likely to receive preferential
flow from a release. For example, if the subsurface soil consisted of interbedded clays and sands, the
lysimeter would be placed in the first sand layer overlying a clay to maximize the potential to detect leaks.
In addition, the distance and depth of the lysimeter influenced the type of lysimeter chosen. When the
distance to the lysimeter was large, high-pressure vacuum lysimeters were used.

Lysimeters were placed 15m from the two containment walls and beneath the neutron probe trench to
detect potential movement of liquids along the top of a fine-grained soil interval. The lysimeter sampling
tubes were routed through the piping containing the soil gas monitoring tubes, which were routed to the
sampling stations.
18

-------
                                                                              Symbol
                                                                            Explanation
                                                                            L    Lysimeter


                                                                            G    Gypsum Block


                                                                            VII  Module Number

                                                                            Surface Water Pond

                                                                     if  Neutron Probe Access Tube

                                                                - -S- -   Soil Qas Sampling Trenches
                                                                       (utilizing and branching off of
                                                                       neutron probe access tube trench)


                                                           ,C) Combination soil gas probe/lysimeter Installation (vertical)


                                                           N) Neutron probe Installation (vertical)
Figure 17. In-plan layout of vadose zone sampling system in California landfill.


                                                                          Reprinted with permission from CuDen, et al., 1994.
                                                     Waste
                                 Drainage layer
                                                                Main leachate collection drain
                                                                               Flexible membrane
                                                                                    liner 
      Gas monitoring
      cross ditch filled
      with drain rock
                      Conduit for lysimeter
                      access tubes and
                      soil gas sample lines
          Compacted low permeability
                    soil liner
                                                                     Neutron access tube, 6'
                                                                     sched 40 steel pipe, back-
                                                                     filled with drain rock only
                                                                     at cross trenches
Pressure/vacuum lysimeter
      Figure 18. Detail of neutron probe access trench with lysimeter/soil gas

      conduit for monitoring California landfill.
                                                               Reprinted with permission from Cullen et al., 1994.
                                                     19

-------
Neutron Probes
A neutron probe contains a neutron source (usually americium-24 I/beryllium) and detectors. The detectors
measure the number of neutrons that are back-scattered from interactions with hydrogen atoms in the
surrounding soil. Neutron collisions with hydrogen produce a characteristic slowing down or
"thermalizing" of the neutron. These thermalized neutrons are counted by the detector. Since most
naturally occurring hydrogen in the Earth's crust is associated with water, the count can be directly related
to the amount of water in the formation. To obtain moisture values, the probe is pulled through a casing,
and a reading is taken at preset intervals. The time taken for each reading determines the precision of the
reading—the longer the count time, the better the precision. When the count is completed, the probe is
moved to the next measurement position (Parasnis, 1997).

Status. The neutron probe is a standard downhole geophysical instrument used for measuring moisture
content in the immediate vicinity (6-12 inches) of a borehole wall. The borehole can be cased or open.

General Attributes. Casings for neutron probes can be installed before construction of the liner or
retrofitted by drilling a horizontal or angle boring. Although operator skill requirements are low, neutron
probes cannot be automated. The operator must pull the probe through each casing to obtain readings,
which can be time consuming. Neutron probes
provide information on changing moisture content in
the immediate vicinity of the casing, not on chemical
speciation or concentration.
Examples. A vadose zone monitoring system that
uses neutron probes is operating at two RCRA
hazardous waste management cells at the Safety-
Kleen facility in Westmoreland, CA. One was
installed at an existing cell. An approximately 50-ft
long borehole was drilled at an angle under the cell
on each side for installation of the casing. The
second cell was constructed with three,
approximately 730-ft long, access tubes equally
spaced under the liner system. Neutron probe
measurements are taken quarterly at 10-ft intervals
in the 730-ft tubes and at 2.5-ft intervals for the
inclined tubes using a Boart Longyear CPN® 503
DR Hydroprobe®. The Hydroprobe uses an
americium-24 l:beryllium source with a helium-3
detector. The soil volume for each measurement is
approximately spherical with a radius of 15 cm.

Sandia National Laboratories (SNL) in
Albuquerque, NM, has constructed a 200-by-300-ft
RCRA (Figure 19) corrective action management
unit (CAMU). Because the depth to groundwater at
Foot print of the
contaminated cell
land surface
200 ft by 300 ft-^,

  Primary sub-liner
  subsystem
  1 of 5 horizontal access
  tubes for Vadose zone
  monitoring system
  (under ceH liner)
    40 ft typical
 Vertical sensor
 array subsystem
 1 of 10 Instrumented
 vertical boreholes
Sloped sides (2:1)
                28.5ft
                    28.5ft
  19.2ft
19.2ft
Figure 19. CAMU vadose zone monitoring
system at Sandia National Laboratories.

                   Reprinted with permission from Studer, 2000.
                                               20

-------
the CAMU is 500 ft, SNL obtained a waiver from the State of New Mexico for installing a groundwater
monitoring system. The approved vadose zone monitoring system consists of five lateral vitrified clay
pipes placed directly under the unit's geomembrane composite liner. These pipes provide access for a
neutron probe. In addition to the neutron probe, five vertical 15-ft deep boreholes were drilled on
approximately 40-ft centers along the two outer access pipes. Similar to the access pipes, these holes are
directly below the liner system. Two instrument arrays were placed in each borehole. The arrays consist of
a time domain reflectometry probe, a thermistor temperature probe, and a soil gas sampling tube. One
array was placed in the native soil at the base of the borehole, and the second array was set 5 ft below the
base of the liner in borehole backfill. Monthly monitoring will occur for a year prior to placement of waste
to establish a base line. Monthly monitoring will continue for as long as the unit is active; then the system
will be monitored quarterly for the first three years after closure. The frequency after three years will be
negotiated (Studer, 2000).

Advanced Tensiometers

Tensiometers consist of a porous cup or plate, a pressure sensor, and a reservoir of water connecting the
two. The instrument is placed in a pre-drilled hole to ensure intimate contact between the cup and the soil.
The soil, unless fully saturated, pulls water from the reservoir through the porous cup until a pressure
equilibrium is attained. The partial vacuum caused by the loss of water in the tube is read by a vacuum
gage or transducer. This reading can be related to soil moisture content. If the moisture content of the
surrounding soil increases, the instrument draws in water and the vacuum pressure decreases. Traditional
tensiometers are generally limited to several meters in depth. The advanced tensiometer (Figure 20) is
designed to overcome this depth limitation and has been used to depths greater than 60 meters.

Status. While traditional tensiometers are well established for measuring soil water potential, particularly
for agricultural uses, advanced tensiometers are a more recent development. They are available
commercially, but the number of vendors is more limited than for those designed for agricultural use.

General Attributes, Advanced tensiometers are placed in pre-drilled holes (generally 3.6 cm or greater).
They also can be nested in a larger borehole so multiple depths can be measured. The measurement gauge
is a downhole pressure transducer that can be queried automatically at preset intervals by a data logger
located at the surface. Because of its depth of operation and the location of its instrumentation downhole,
it is not subject to diurnal temperature and barometric pressure fluctuations. Access to the installation is
required for periodic transducer maintenance and replenishment of the water reservoir. The instrument can
be installed in directionally drilled holes or horizontal ones as well as vertical holes. Optimum
interpretation requires calibration with site-specific soils, and tensiometers in general are not accurate in
dry soils. More information is available at http://tech.inel.gov/tech-detail.asp?id=50.

Examples. While the technology has been demonstrated at several sites, no long-term monitoring
examples were found.
                                               21

-------
                                                                           •Surface cap
             -Electric lead
             -Air line

             -Inner guide pipe
             -Pressure transducer
?	Connector  AdapterJ
N	Gasket        K  \
A
Outer guide pipe
    (1"PVC)
                                          Gasket throat

                                          Water reservoir

                                          Porous ceramic cup
•                             Gasket seated
                             in gasket throat
                                                                                     Water
  Figure 20. Configuration of an advanced tensiometer.
                                                                          Courtesy: U.S. Department of Energy.
3.3.9 Wire Net Designs

The wire net design consists of two arrays of parallel stainless steel wires arranged orthogonally and
separated by a thin layer of a permeable, but resistive material, such as sand. A multi-core cable connects
each wire to measurement equipment (Figure 21). The released material must provide an electrical
contrast to the sand. The system checks for all possible combinations of shorting in the grid and, in doing
so, can accurately identify where a release has occurred. An alternative design positions the wires located
immediately above and below the geomembrane liner. A leak causes the resistance between the nearest
wires to decrease significantly.

Status. The wire net design was specifically developed for vadose zone monitoring at containment sites. It
is estimated that fewer than five have been deployed (Peggs, 1999).

General Attributes. Wire net designs are easy to construct and made of relatively inexpensive materials.
They must be installed when the containment unit is built. Generally, a trained operator queries the system
daily.
                                                22

-------
                                     b)
1





—— — Topvrir


e layer
wire layer

Computer H JJ^JJJ,.
A/D eonvwter 1 1 Booster
M Switching unK


IUghtnlng
protection



t._-





.1-
jlti core cable connected to the wires
£
.
-
sann "^*
1-1*101 ' • * 5 S • . ! • ! 5


• 
'v'-C
, V'^F
- -
.
V
- ; t '
•^•'\ "




f/
****•»&
iV
^\£? ;
"/^v>

:,

,

' '•''-'
"'i
- , ^;^
"" <:%
'^••i-\"^f
•;,.. C*:
,^ Wj:;,
^f^C* ',
'<




v"
-,
*';"


if''',."/-
's'"''j|-*i
'•1 ^ ./'^
•/".-~-J
tlL




>


y

(x1) 
-------
General Attributes. While relatively simple to install, cable network sensors can only be deployed when
the containment unit is being constructed. Interpretation of the data requires a trained operator. The system
requires calibration using an
independent standard, which may
not reflect soil moisture content
across the unit.                                              40m
                                     I
                                     
-------
4.0  FINAL COVERS

As discussed in Section 3, active landfills are open to the atmosphere, which allows precipitation to enter
and interact with waste to form leachate. The liner system must contain the leachate until it can be removed
and treated. Once a landfill cell is full, a final cover is placed over the waste to prevent additional water
from entering and generating more leachate. By preventing the entrance of water into the landfill,
eventually all the liquid in the landfill will be collected and treated, and the liner will no longer need to act
as a barrier to leachate migration. Some landfill owners minimize the amount of leachate generated during
the active life of a landfill with a "cover as you fill" strategy  in which waste is covered as soon as a section
of a cell is complete (EPA 2002).

4.1 Design

The design requirements for hazardous waste (RCRA Subtitle C) covers are performance based and are not
prescribed by specific regulations. The covers are designed to:

•     Minimize migration of liquids long-term.
•     Function with minimum maintenance.
•     Accommodate settling and subsidence.
•     Have a hydraulic conductivity less than or equal to any bottom liner or natural subsoils present.

MSW (RCRA Subtitle D) covers function the same way, but have more specific design requirements (U.S.
EPA, 1985a; 1985b; 1987; 1989a; 1991; and 1993a).

Because the design of a final cover must consider climate, waste characteristics, and other site-specific
conditions, the minimum design recommendations may be altered provided that the alternative design
meets the intent of the regulations. For example, freeze/thaw cycles will damage a cover's compacted soil
layer. Hence, in northern parts of the country where the soil can freeze to depths greater than 60 cm, a
thicker vegetation/soil layer is needed to protect the compacted soil layer. Although other layer types may
be called for on a site-specific basis, the most common optional layers are used to collect gases and create a
biotic barrier to prevent the intrusion of plant roots or burrowing animals.

4.1.1 RCRA Subtitle  C

Since they are used for hazardous waste containment, Subtitle C covers are the most protective and
expensive to install. EPA issued minimum design guidance for covers under Subtitle C. The recommended
design, as shown in Figure 23, consists of the following layers:

•     Low Hydraulic Conductivity Geomembrane/Soil Layer: A 60-cm layer of compacted, natural, or
      amended soil with a hydraulic conductivity of IxlO"7 cm/s in intimate contact with a minimum
      0.5-mm (20 mil) geomembrane liner (60 mil if the liner is HDPE).

•     Drainage Layer: A minimum 30-cm layer of soil having a minimum hydraulic conductivity of IxlO"2
     cm/s, or a layer of geosynthetic material having the same characteristics. The drainage layer should
     be covered by a sand filter or geosynthetic filter layer.

•    Top. Vegetation/Soil Layer: A top layer with vegetation (or an armored top surface) and a minimum
     of 60 cm of soil graded at a slope between 3 and 5 percent.


                                              25

-------
4.1.2 RCRA Subtitle D

As specified in 40 CFR 258.60(a)(l-3), a
Subtitle D cap must, at a minimum:

•     Have a permeability less than or equal to
      the permeability of any bottom liner or
      natural subsoils present, or a
      permeability no greater than IxlO"5
      cm/s, whichever is less.
•     Minimize infiltration through the
      containment unit using an infiltration
      layer that includes a minimum of 45 cm
      of earthen material.
•     Minimize erosion of the final cover
      using an erosion layer that contains a
      minimum of 15 cm of earthen material
      capable of sustaining native plant growth.

Hence the minimum profile for a Subtitle D
cap is a 15-cm vegetative erosion layer over  a
45-cm engineered soil infiltration layer
(usually a composite barrier of a.
geomembrane [GM] and compacted soil) that
blankets the waste (Figure 24). Typically
cover designs include other components, such
as a drainage layer and gas collection system.

4.2 Monitoring
             .'\:;-f. Sand drainage layer, \y»-V- ^ QM
             '.'•*•/•'.•/.•" ka Iff* cm* '••'•• f-:'-!'i^^
             'v; CCL^ k 5JOf cmfs >v; [- Composite barrier
          _>_ *,f«'..-:. *.-:. •j.f.;. f. f. fjjsspfvi
      ft* requited v?>:Gas drainage layer>>S
          T'"	""
 Figure 23. Typical Subtitle C cover.
                                       Source: EPA 2002.
Figure 24. Typical minimum Subtitle D cover.

                                       Source: EPA 2002.
Subtitles C and D do not specify any direct
monitoring requirements for covers. They do, however, require that the integrity and effectiveness of the
final cover be maintained. Maintenance could include a monitoring or inspection system to detect the
effects of settlement, subsidence, erosion, or other disturbances, and prevent run-on and run-off from
eroding or otherwise damaging the final cover. Subtitle D requires a gas monitoring system to ensure that
no dangerous buildup of methane gas occurs.

While the federal regulations do not require monitoring systems for covers, some states, like California, do
require them. California Title 23, Division 3, Chapter 15, Article 9, Section 2597(b) has a performance
requirement for cover monitoring that applies to landfill areas that will be redeveloped for purposes other
than non-irrigated open land. The owner/operator must provide a water balance study (an
evapotranspiration study that shows that irrigation water  plus expected precipitation will not impact the
liner integrity) at the site and detailed design plans and description(s) of the monitoring system(s) that will
effectively detect penetration of the final cover by precipitation or applied irrigation waters.
                                               26

-------
4.3 Leachate Inventory and Survey

Long-term monitoring systems for covers are primarily performance based and do not generally require
direct measurements. The most typical system used for cover leaks is to monitor the flow of leachate in the
leachate collection system. Visual inspection of the cover (or survey marker comparison) is the industry
standard for detecting settlement and subsidence.

A leachate inventory is a surrogate method for examining cover integrity and is required for hazardous
waste liners, although it is not required for MSW liners. As a result, it is the most common method used to
determine if the cover leaks. The inventory involves comparing the volumes of liquid being pumped or
treated in the containment leachate collection system over time. For a closed cell with a final cover, the
volume of liquid should decrease over time. If the cover leaks, the volume of liquid should increase.
However, depending upon the type and volume of waste, even a large breach in the cover might go
unnoticed for a long time, and clogging of the collection system could mask infiltration rates (EPA 2002).

Survey techniques are used to evaluate potential subsidence and settlement problems. Subsidence occurs
when one part of a landfill loses mass faster than another, creating differential elevations that can cause the
cover to rupture. Settling usually occurs at MSW landfills as the materials in them biodegrade over time.
This type of mass loss has potential to damage the integrity of cover systems, but usually does not result in
the high tensile stress caused by differential subsidence and the accompanying ponding of water.

There are two general techniques for monitoring the subsidence and settlement of landfill covers. The first
method involves surveying the position of monuments placed on the landfill surface at closure. The
monuments are surveyed initially for elevation and then periodically re-surveyed to determine if their
elevation has changed. A significant change in the elevation of one monument relative to the others would
indicate differential subsidence that can stress cover materials and cause failure. General loss of elevation
compared with a survey marker located away from the landfill proper indicates settlement is occurring.

The second method for monitoring subsidence and settlement, which is usually combined with the first,
involves creating topographic maps with relatively small contour intervals. Topographic maps can be
highly accurate if they are created using aerial photographs as well as survey data. Topographic maps are
created after the containment unit is closed. Subsequent aerial photographs can be compared with the
baseline map to determine if there has been any subsidence or settlement. This method is more expensive,
but also is much more accurate than using survey markers alone.

4.4 Technologies

Although direct measurements are not typically required for the performance monitoring of landfill covers,
technologies are available for monitoring beneath covers. However, as a result of the landfill gases that
accumulate under the cover, many of the devices used in liner monitoring cannot be used to monitor covers
because they will detect the gases. Furthermore, monitoring beneath covers requires access to the
monitoring devices through the cover, which can increase monitoring and maintenance costs; landfills that
are subject to differential subsidence or settlement will present additional design and maintenance
problems. Despite these potential obstacles, liner monitoring devices may be useful  in some cover designs.
The portable electrical system design listed below requires a single access point to materials lying beneath
                                               27

-------
the cover geomembrane, but the actual measurement and leak detection activities take place on top of the
cover. Hence, it avoids most access, settlement, and subsidence issues.

Alternative cover designs for landfills in arid and semi-arid climates often rely on the field capacity of the
cover soil, rather than a low permeability barrier, to prevent infiltration of the landfill wastes. In these
instances, monitoring is done to ensure that moisture is not reaching a calculated depth into the soil layer
where the monitoring devices would be placed. Liner technologies, such as lysimeters, and capacitance
sensors are effective, as are any of the electric grid designs. Technologies specific to covers include fiber
optic stress gauges and open-path Fourier transform infrared spectroscopy.

4.4.1 Moisture Measuring Devices

As discussed in Section 3.3.8, capacitance sensors, neutron probes, and lysimeters are moisture measuring
devices that can be used to monitor landfill liners. These devices also can be used in monitoring alternative
cover designs that rely on the grain size of the cover soil, vegetation, and field capacity to prevent water
from infiltrating the waste. The devices are placed within the cover to monitor moisture content and show
that saturated conditions are not reached. All of these instruments have been used for landfill cap
monitoring.

Examples. A monolithic, evapotranspiration cover consisting of 1.5 m of gravelly sand with silt was
installed at the Phelan Landfill in Phelan, CA. Performance is being monitored with four 0.9-m wide by
15.25-m long HDPE lysimeters consisting of a 40-mil HDPE geomembrane overlain with two layers of
geo-grid and a geotextile to collect percolation. The percolation is measured with a tipping bucket gauge at
a resolution of 0.025 cm. In addition, there are eight soil moisture capacitance probes located at each
lysimeter to monitor soil moisture.

Neutron probes are used to monitor the performance of a capillary barrier style cap at the Gaffey Street
Sanitary Landfill in Wilmington, CA.  The cover was constructed with 1 foot of vegetated soil, 3 feet of
silty sandy soil, an 8 oz/yd2 geotextile filter and 0.5 foot of drainage gravel. Dry wells have been placed in
the cap at two locations, and probes are periodically run down them to check for moisture content.

A seven acre  monolithic evapotranspiration cover was used at the Coffey County Landfill in Burlington,
KS. The cover consists of six inches of topsoil cover over 42 inches of compacted silty clay. Two
approximately 15-m long by 9-m wide lysimeters were placed at the base of the silty clay to monitor cover
performance.

Tensiometers

While the mechanism of operation is the same as was described for advanced tensiometers in Section 3.3.8,
tensiometers used for cover monitoring do not have the depth or distance requirements that may be needed
for monitoring liners.

Status. Shallow tensiometers were developed to measure soil moisture primarily for scheduling agricultural
irrigation events. They have been employed in agricultural and forestry applications for many years and are
an established technology with many vendors.
                                               28

-------
General Attributes. Tensiometers can be grouped into two broad designs—those that use vacuum dial
gages (Figure 25) and those that use pressure transducers. The dial gauge design is less expensive but is not
generally automated. Dial gauges also are usually located at the surface of the ground and are affected
by barometric pressure and temperature changes,
which must be accounted for in data interpretation.
Pressure transducer tensiometers, while more
expensive, can be automated and queried remotely,
thereby saving on labor costs. Depending upon the
design, they too can be subject to barometric
pressure and temperature fluctuations. Both
categories need their water supply manually
replenished on a regular basis.

Examples. No examples of commercial deployment
of tensiometers for monitoring covers were found.
They have been used by various groups to
investigate the viability of alternative landfill cover
systems.

Time Domain Reflectometry Probes

Time domain reflectometry probes operate similarly
to the cables described in the liner Section 3.3.5. A
very fast step voltage increase is sent by a cable
tester down a co-axial  cable to a probe that contains
two (Figure 26), three, or four prongs. The tester
(generally with a fast oscilloscope) captures the
reflected waveforms and can be set to capture all or any
part of the wave including those from the probe alone.
The reflected waveforms indicate changes in
permittivity or impedance in the material  between the
conductors. The materials causing these changes would
be the plastic separating the two wires, the plastic head
holding the rods in place in the probe, and the soil
between the rods. The  permittivity of the  soil is a
function of soil type and moisture content. Hence, for
accurate readings the probe should be calibrated to site-
specific conditions.

Status. TDR probes were originally developed to
measure soil moisture  for agricultural applications and
are  widely available though a number of vendors. More
recently they have found application in monitoring soil
moisture in alternative landfill cover designs.
                            —Vacuum
                              Gauge
             — Hollow Tube
             — Ceramic Cup
Figure 25. Gage tensiometer.
                     Courtesy: University of California, Davis.
   Figure 26. Time domain reflectometry
   probe.

                  Courtesy: U.S. Army Corps of Engineers.
                                               29

-------
General Attributes, TDR probes can be multiplexed and used for unattended automated data collection.
They can be set at different depths to provide a soil moisture profile within a landfill cover.
Calibration/interpretation problems may be experienced when the probes are placed in dry soils with low
bulk density or when deployed in soils containing expansive (smectite) clays (Evert, 2000).

Examples. An evapotranspiration cover was placed over the 100-acre Coyote Canyon Landfill located in
Somis, CA. The design of the landfill cover consists of a 30-inch fine sand barrier layer overlain by a 78-
inch vegetative layer that was made with locally obtained borrow soils. The moisture content of the cover is
measured by three stacks of TDRs. The TDRs were placed at depths of 6, 12, 24, 36, 51, 66, 84, 93, and
102 inches and initially monitored on an hourly basis. The TDRs have shown moisture intrusion into the
cap to a maximum depth of 36 inches.

An evapotranspiration cover was placed over the 166-acre Lopez Canyon Sanitary Landfill located in Los
Angeles, CA. The landfill cover consists of a 3-foot silty sand/clayey sand layer, which overlies a 2-foot
foundation layer. Two of the four cell covers have monitoring systems that consist of two stacks of TDR
probes, that measure soil moisture at 24-inch intervals to a maximum depth of 78 inches.

For more examples of covers and monitoring systems see:
http://cluin.org/products/altcovers/usersearch/lf_search.cfm

4.4.2 Electrode Grids

While not common, electrode grid systems similar to those discussed in Section 3.3.6 for liners can be used
for monitoring landfill covers. Differential settlement issues can make their design difficult and their long-
term viability problematic.

An automated electrode grid was deployed at a former mining site as part of a cover monitoring system
(U.S. DOE, 2003). The 62-acre rock dump (sulfidic waste rock and spent heap leach ore) was covered with
a geotextile overlain by 15 feet of soil. Before placing the cover, 600 stainless steel electrodes, each
connected to 18-gauge copper wire, were placed on a 25-foot center grid over the waste. The wires connect
to a control station where the electrodes can be queried to generate a detailed resistivity map. The electrode
grid provides information on moisture changes within the pile and detects whether any moisture is
penetrating the cover. Design and maintenance issues were greatly reduced at the rock dump site because
the dump is not expected to settle or subside
(http://subsurface.inel.gov/inf6rmation/newsletter/Vol4Issl/giltedge.asp).

4.4.3 Portable Electrical Systems

The portable electrical system described in Section 3.3.7 of the Liner Chapter can also be used to locate
leaks in cover systems containing geomembranes. The geomembrane cover leak location method transmits
an electrical current from an electrode in a conductive medium above the liner (Figure 27). The current
flows through any breaks in the liner and is received by a second electrode placed in a conductive medium
below the geomembrane  liner. Electrical potential measurements on the surface of the conductive media
using moving electrodes  locates holes in the liner. The high current density caused by localized current
flowing through the holes causes a localized characteristic leak signal that can be located with great
accuracy.
                                               30

-------
Status. The system was designed for locating leaks in geomembranes and is commercially available. It has
been widely applied in both the United States and abroad and is offered by over 20 vendors. ASTM
Standard D 7007 includes standard practices for locating leaks in geomembranes covered with earthen
materials.

General Attributes. Geomembrane leak location surveys can be applied at any time on any containment
cover that has a geomembrane liner. The results are available in the field. It does not require sensors and
associated cabling to be installed during construction of the cover. There is no up-front investment needed
for installation so the method can be applied only if indicated by increased leachate levels.
                                          LANDFILL
                                           COVER
                                                                            DIGITAL
                                                                            DATA
                                                                            RECORDER
                              GEOMEMBRANE
LANDFILL
     Figure 27. Monitoring cover using a portable electrical system.
                                                                        Courtesy: Leak Location Services, Inc.
Examples. While portable electrical systems could be deployed for long-term monitoring, no examples
were found. The system is most often used for spot checking when a problem is suspected or the integrity
of the liner is an important safety concern. Examples of the former: a survey at a CERCLA landfill cover in
New York after construction damage was noted in the geomembrane and a survey at a large landfill in
Connecticut after leachate levels were observed to be increasing. The survey of a Kentucky landfill that
contained hydrogen cyanide waste is an example of monitoring for safety reasons.

4.4.4 Fiber Optic Stress Gauges

Fiber optic stress gauges use changes in light reflectance to sense deformation. By attaching fiber optic
cables to the underside of a geomembrane cover, changes in the membrane position due to subsidence and
settlement can be detected and, depending upon the density of the attached cables, accurately located.
                                               31

-------
Status. Fiber optic stress gauges function in much the same fashion as metal stress gauges, which are used
to measure deformation of a material from its original emplaced form. Metal gauges have been employed in
the construction industry for a number of years and generally rely on a change in the resistance of the metal
when it is deformed.

General Attributes. Fiber optic stress gauges for landfill cover monitoring have not been commercialized.
If used, fiber optic stress gauges must be installed during initial construction of a cover. The cables are
attached to a central control unit that tests them on a predetermined schedule. This type of system alerts the
operator to a shift in the geomembrane cover due to lateral sloughing of the cover material or vertical
displacement due to differential subsidence. Near continuous and automated monitoring provides for
relatively inexpensive operation. However, the gauges may need to be replaced after detecting movement.

Examples. SNL has been conducting experiments to automate the detection of differential subsidence using
geomembranes with embedded fiber optic stress gauges (Boras, 1997). By incorporating fiber optics into
geomembranes, the SNL has produced a membrane that can be monitored for strain. This capability is
especially useful for detecting stretching and tearing in geomembrane liners and covers. Strain detection is
possible because the fiber optic lines are crimped into small folds called "microbends." These microbends
are either distributed evenly along the entire optical fiber, or the fiber has short sections of microbends a
few meters apart. As the geomembrane tears or stretches, the microbends flatten out, changing the way
optical signals are reflected through them.

Field-scale testing on the SNL Geosynthetic Membrane Monitoring System was completed in October
1997. During the test, a 43-by-4.5-m section of geomembrane was installed as a cover over a test facility
that was designed to simulate both local and general subsidence.  The strain in the geomembrane was
measured for three months as water and air drained from fabric bladders and inner tubes in the test cell. The
strain data indicated the location and magnitude of the subsidence.

4.4.5 Fourier Transform Infrared Spectroscopy

FTIR spectroscopy measures the chemical absorption of specific  energy bands in the infrared (IR)
spectrum. Not all chemicals absorb in the IR range of a given instrument, but those that do create a pattern
unique to each. Detection by IR analysis is accomplished by measuring the absorption of energy by
molecules in a target sample. The concentration of the chemical can be estimated from the amount of
energy absorbed. FTIR instruments can be deployed either in an open path mode or through the use of a
portable cell. A typical open path FTIR spectroscopy system includes an IR source, a Michelson
interferometer, beam splitter, helium-neon laser for beam alignment, collimating telescope, and detector.
The system can be set up in either a bistatic or monostatic configuration (U.S. EPA, 1999). In the bistatic
configuration, an IR source transmits a beam of energy directly through the area where chemical
measurement is desired to a receiving detector on the other side, In the monostatic configuration, an IR
source transmits a beam of energy through the area where chemical measurement is desired to a
retroreflector that reflects it back through the area to a receiving detector, hi both configurations, the
concentration reported is an average over the area traversed. With-portable cells air is drawn into the cell
where it is queried by bouncing a light beam repeatedly between  the ends of the cell. After a fixed number
of bounces the light exits the cell where it is captured by a detection system that measures the amount of
energy absorbed.
                                              32

-------
Status. Open-path Fourier transform infrared (OP-FTIR) spectroscopy is an established analytical
technique that measures the concentrations of non-atmospheric gases that may escape from a landfill cover.
If gases escape from a section of the cover, presumably liquids can infiltrate the containment unit via the
same conduits. The primary use of OP-FTIR in hazardous chemical work has been for fence-line
monitoring at industrial sites and remedial action sites. FTIR cell systems are also established and find their
principal use in laboratory settings.

General Attributes. An OP-FTIR spectroscopy system can be deployed as a permanent system or as a
temporary one to periodically check for releases. The technology is capable of identifying a broad range of
chemicals in the low ppbv range. In general, a total travel distance of 100 meters or more is required to
achieve good detection limits. While automated systems have been used in industrial fence-line
applications, detection of cover leaks would likely require a radial configuration of multiple points, that
cannot be automated. A skilled operator is needed for OP-FTIR spectroscopy.

Examples. EPA used OP-FTIR spectroscopy to determine if gases escaping from a closed Superfund
landfill will present a health risk to people if the landfill is redeveloped into a soccer field. The landfill
cover was gridded, and retroreflectors were placed in each grid cell. This configuration allowed average
measurements to be taken over increasing distances and also provided for good area! coverage. The field
work took three days and identified three separate methane gas releases. No other contaminants were
detected. Detection limits generally ranged between 4 and 60 ppbv (U.S. EPA, 2004).

I-CORP International, Inc. has deployed a portable FTIR spectrometer that is mounted on a vehicle. The
instrument can measure the distribution of methane, non-methane hydrocarbons, and carbon dioxide. When
these measurements are combined with a global positioning system, exact locations of gas concentrations
can be mapped. The spectrometer has an 8-foot long sample cell  that is moved across the cover. As the cell
moves, air flows through it and potential contaminants are measured. I-CORP reports a sensitivity of less
than 0.1 ppm when analyses are conducted every second. However, with somewhat less sensitivity, the
instrument is capable of producing 100 readings a second, and hence can provide near continuous data as it
traverses the cover.
                                              33

-------
5.0   SUMMARY AND DISCUSSION OF FINDINGS

LINERS

The industry standard for monitoring beneath the liner of a containment unit is to place groundwater
monitoring wells at the downgradient edge of the unit and periodically test the groundwater for changes in
its quality. In the event that an alternative to groundwater monitoring is needed or required, this study
identified 13 technologies that have been used to monitor the vadose zone beneath a containment liner, or
have the potential to do so. Table 1 summarizes the key attributes of these technologies.

Advanced tensiometer. Advanced tensiometers are a variation on traditional tensiometers that allows them
to be automated and deployed at depth (60 meters or greater) and at angles ranging from horizontal to
vertical. They are used to measure the moisture content of the soil in then* immediate vicinity. They can be
deployed during or after the construction of the landfill liner but their location must allow access for
maintenance.

Cable network sensor. Cable network  sensors are an experimental technology developed in Europe. They
measure the change in the dielectric of clay, which is used in the compacted soil layers of liners. The
change in dielectric is brought about by a change in moisture content. The released liquid must be capable
of changing the dielectric of the clay, but does not need to directly contact the cable. The sensors are placed
in the soil when the containment unit is constructed and must be queried by a trained operator.

Capacitance sensors. Capacitance sensors were developed primarily for use in agriculture and
construction. The sensors measure the  moisture content of the soil in their immediate vicinity. Hence, for
use at landfills they must be placed during construction at points deemed most vulnerable to leaking or in
areas where infiltrating leachate might be expected if a failure occurs. Capacitance sensors can be
automated and do not require highly skilled operators.  One landfill in California was identified as having a
capacitance system in place.

Diffusion hoses. While diffusion hoses have been deployed beneath landfills in Europe, they are used
mostly in detecting releases from equipment, tanks, and pipelines at chemical and petroleum facilities.
Diffusion systems detect chemical vapors that are released from chemical spills or leachate releases that are
capable of diffusing through their permeable tubing walls. If there are no volatile compounds in the
leachate, then diffusion hoses will not detect the release. Diffusion hoses can be placed during or after
construction of a containment unit and are typically automated. They can provide chemical concentrations,
speciation, and, depending on the design of the monitoring system, its specific or general location.

Electrochemical sensing wire cables. Electrochemical sensing wire cables have been installed to monitor a
doubled-lined hazardous waste acid impoundment. However, in general, these cables are used primarily for
detecting releases from equipment, tanks, and pipelines at chemical and petroleum facilities.
Electrochemical sensing wire cables rely on a direct interaction of the cable with the liquid, which triggers
a short between a continuity line and an alarm line. The cables are all continuous, fully automated systems
that can determine the exact location of a release. Some cables must be replaced if a release occurs, and if
the  leak is not repaired, the system will emit a continuous alarm. The cables require a protective, perforated
piping to avoid being crushed. This piping allows for the maintenance and replacement of cables. The
piping can be placed either during construction of the containment unit, or afterward using horizontal
drilling.


                                               34

-------
 Electrode grids. Electrode grids were developed specifically for monitoring beneath the liner of a landfill
 or impoundment. They measure points where electrical current flows through breaks in the liner or measure
 changes in the localized resistivity of the conductive layer caused by fluids flowing through the breaks.
 Over 120 electrode grids have been deployed. They consist of a series of electrodes individually connected
 by cables to a central processing unit. The grid is placed beneath the liner during construction of the
 containment unit.

 Portable electrical systems. Portable electrical systems are used extensively as a quality assurance tool
 following liner construction, but no examples of their use in permanent monitoring systems were identified.
 The system detects holes in the liner by impressing a current between an electrode located within the liner
 system and an electrode grounded outside the liner system. A detection probe is then used to scan the liner
 to locate any leakage of current caused by breaches in the liner. The system can be used over the service life
 of a surface impoundment but is generally restricted to construction quality assurance for landfill liners.

 Intrinsic fiber optic sensors. Intrinsic fiber optic sensors are primarily  used for leak detection in the
 chemical and petroleum industries. The sensors are chemically sensitive to a target chemical or class of
 chemicals. As a chemical or class of chemicals is adsorbed by the sensor, it changes the effective index of
 refraction of the sensor, which is determined by measuring the amount of light transmitted through an
 optical fiber. The probes generally have to be regenerated over time. This regeneration requires that they be
 placed in accessible locations, such as dry, vertical, perimeter wells or in perforated piping laid under the
 liner. No examples of the deployment of intrinsic fiber optic sensors at a landfill were found.

 Lysimeters. Lysimeters are used primarily in agriculture for irrigation programs and water balance studies.
 They are commonly deployed at landfills in California. There are two basic designs: (1) suction lysimeters,
 which sample pore water under negative pressure;  and (2) plate/pan lysimeters, which collect free-flowing
 percolation. In general, they are placed during construction of the landfill and are sampled manually.
 Lysimeters measure a limited area around and/or above them and may collect insufficient sample volume if
 speciation of the chemicals is desired.

 Neutron probes. Neutron probes are a standard geophysical instrument used to measure the moisture
 content of the soil in the immediate vicinity of an open borehole or well casing. It works by counting back-
 scattered neutrons that have been slowed down by  their interaction with hydrogen atoms. The count is
 directly related to the amount of moisture in the formation. When used at landfills, neutron probes must be
 pulled through horizontal or angled piping, which can be placed during construction or retrofitted. Several
 landfills in the western U.S. employ neutron probes as part of their vadose zone monitoring system.

 Soil gas. Soil gas systems are primarily used in site characterization studies and for leak detection
 monitoring at petroleum and chemical facilities. Soil gas systems measure volatile chemicals that have
 partitioned into the soil gas from escaping leachate. In passive soil gas systems, a sorbent device is placed
 in a dry well and the sorbed chemicals are measured after a pre-specified period of time. In active soil gas
 systems, the soil gas is pumped from the dry well and analyzed. Passive systems cannot be automated, but
 active ones can. In  silty and clayey soil, the time required for detecting  a release can be quite long.
 Depending upon the number and placement of the dry wells, soil gas systems can identify the release
 location. Several landfills in the western U.S. use soil gas systems as part of their vadose zone monitoring
program.
                                               35

-------
 Time domain reflectometry detection cables. Although time domain reflectometry detection cables are
 primarily used to detect releases at petroleum and chemical facilities, they have been used for vadose zone
 leak detection under double-lined acid impoundments and for monitoring piping that transports leachate
 from a landfill to a holding or treatment center. Time domain reflectometry depends on a change in
 impedance in the cable caused by an infiltrating liquid or gas. The distance to the change in impedance is
 easily calculated to determine the general area of the release. The cables must be shielded in protective,
 perforated piping, which can be installed while the containment unit is being constructed or as a retrofit.
 The cables are fully automated, and if the leak is repaired the cables can be dried and reused.

 Wire net. Wire nets were designed to monitor the vadose zone beneath containment unit liners and have
 been deployed at several units in Europe. A wire net consists of two arrays of orthogonally oriented wire
 electrodes that are separated by a thin layer of permeable, but resistive material, such as sand. The system
 detects leaks in the liner by measuring changes in the resistivity between the wire electrodes. In general, the
 system must be queried by a trained operator.

 COVERS

 The primary reason for performance monitoring of covers is to make sure water is not introduced to the
 landfill wastes. The industry standard for monitoring cover integrity is to visually inspect the cover and to
 measure leachate production over time to ensure that the volume is decreasing. Four of the technologies
 used to monitor liners—capacitance sensors, lysimeters, electrode grids, and portable electrical
 systems—have also been deployed for covers. Two more of the technologies that are found in the liner
 section—tensiometers and time domain reflectometry are also used to monitor covers but they use a
 different configuration and are discussed below. Two additional technologies—fiber optic stress gauges
 and Fourier transform infrared spectroscopy—were identified as having been designed for or deployed in
 final cover monitoring.

 Fiber optic stress gauges. Fiber optic stress gauges are an experimental technology designed specifically
 for measuring deformation of geomembranes caused by lateral sloughing or vertical displacement, which
 can occur during settlement and subsidence. Fiber optic cables are attached directly to  a geomembrane
 cover when it is installed. These cables measure changes in reflectance that are indicative of changes in
 their position on the geomembrane. A change in position is generally caused by a shift in the geomembrane
 due to general or differential settlement. The location of the reflectance change is easily determined. While
 the system does not indicate that a breach has occurred in the cover, it does alert the operator to a potential
 problem.

 Fourier transform infrared spectroscopy. h'llK spectroscopy is primarily used in the environmental field
 to monitor volatile chemical releases from industrial facilities and remediation actions  at the fence line.
 Open path-FTIR spectroscopy provides an average concentration of a variety of organic and inorganic
 chemicals at the ppbv level over preset distances. A radial survey approach is used when monitoring a final
 cover, to locate hotspots caused by escaping volatiles. If a hotspot allows a significant release of gas, it
 might also allow water to enter the landfill. FTIR equipment can also be mounted on a vehicle, which can
be driven across the top of the cover to look for hotspots. When the vehicle is equipped with a GPS, exact
 locations of hotspots can be mapped as they are encountered.

 Tensiometers. Tensiometers measure soil moisture content in the immediate vicinity of their porous
ceramic cups. They can be deployed singularly without automation or multiplexed with automation. They
                                               36

-------
OJ
-0
Demonstration
00
1
n
Q

f/"1
3'
E2



^
\
\
^

^

\
\
\
\

^
g
0
!
o
1
3
r*
S*
£3
fH






^
\

^

^
^
^
^

^
Commercially
j>
<
pa
s*
o






^

^
\
\
\
^
^
^
^
\
^
^
Retrofitted











W


*
Cd 5

Cd 15

W
Cd 5
td 5
td 5

Identifies Cher

8.
n
P
w

O
n
|
a
^



\
^

^
^


\
^

1 Identifies Cont
5

n











\


\
^


\


\ Determines Vc
g"
i
o
H*»
W
n
o
O)




\



^






^
| Locates Generi
&
^~
S
0
>-h
JO
n
1




\

^
\
^
^


^
^
^
^
1 Locates Discre
ff

B
Q
Ht)
M
P,




\

^
^
^
^

^
^
^

\
^
| Unskilled Opei

a











^
^
^

^
^
^


^

[ Continuous Of

'i.
§








^



^
^
\




^

| Automated











^

^
^
^
^
^


^
\
\

cr
c
ff











Advanced Tensiometers
Cable Network Sensors
Capacitance Sensors
Diffusion Hoses
Electrochemical Sensing Wire Cables
Electrode Grids
Intrinsic Fiber Optic Sensors
Lysimeters
Neutron Probes
Portable Electrical Systems
Soil Gas Systems
Time Domain Reflectometry Detection Cables
Wire Net Design
51
2
(D
                                                                                            I

                                                                                            §
                                                                                            i
                                                                                            (0
                                                                                            0)
                                                                                            a
                                                                                            o
                                                                                            (A
                                                                                            (D


                                                                                            i1
                                                                                            (D
                                                                                            (Q

                                                                                            «

                                                                                            |

                                                                                            (0


                                                                                                          O JJj
               8*
               £
               c

               8-

               B'

               3
                3

               CTQ

                O



                I


               $
                en
                                                                                                  -
     ill
3

I



I


I
                                                                                                            m

                                                                                                            o
                                                                                                            en
                                                                                                            O
                                                                                                            1
                                                                                                            en

                                                                                                            S,
                                                                                                            ta

-------
                                      REFERENCES

Akgun, H. and R. Wallace, 1996. Leakage detection in lined systems. Journal of Solid Waste Technology
Management, Vol 23 No 2, p 67-71, May 1996.

Anderson, R., G. Young, and T. Crist, 1997. Subsurface landfill gas monitoring strategies in California.
California Integrated Waste Management Board, Sacramento, CA. Proceedings of the 1997 13th
International Conference on Solid Waste Technology and Management. Part 1  (of 2) 16-19 November
1997, Philadelphia, PA. Widener Univ., School of Engineering, Chester, PA. E.I. Conference No. 47586,
Vol 1, 8 pp.

Barrie, S., 1998. An eastern European perspective on leak detection. Waste Management, p 36-37, Apr
1998.

Bemstone, C, T. Dahlin, P. Ulriksen, J. Claesson, 1998. A wire net design for electrical monitoring of
environmental barriers. The Symposium on the Application of Geophysics to Environmental and
Engineering Problems (SAGEEP), 22-26 March  1998, Chicago, Illinois, p 645-653.

Bonaparte, R., 1995. Long-term performance of landfills. Proceedings of the ASCE Specialty Conference
Geoenvironment 2000. ASCE Geotechnical Special Publication No. 46, Vol. 1, p 415-553.

Boms, D., 1997. Geomembrane with incorporated optical fiber sensors for geotechnical and
environmental applications. Proceedings of the International Containment Technology Conference, St.
Petersburg, Florida, p 1067-1073.

Brandelik, A. and C. Huebner, 1997. Large-area, long-term monitoring of mineral barrier materials.
International Containment Technology Conference: Proceedings p 1060-1066.

Coluci, P., F. Crozier, and D. Laine, 1996. Geomembrane liner testing using the GLLS: a high-voltage
electrical leak location system. Geosynthetics: Applications, Design and Construction, 30 September - 2
October, 1996, Maastricht, Netherlands.

Cullen, S., J. Kramer, and J. Luellen, 1994. A risk-based approach to the design of a vadose zone
monitoring system for a solid waste landfill. 87th Annual Meeting and Exhibition Air & Waste Manage-
ment Association, Cincinnati, OH, June 19-24, 1994.

Darilek, G. and L. Miller, 1998. Comparison of dye testing and electrical leak location testing of a solid
waste liner system. Proceedings of the Sixth International Conference on Geosynthetics, 25-29 March
1998, Atlanta, Georgia. Industrial Fabrics Association International, St. Paul, MN. ISBN: 0093583076.

Darilek, G. and D. Laine, 1999. Performance-based specification of electrical leak location surveys for
geomembrane liners. Conference Proceedings of Geosynthetics '99,28-30 April 1999, Boston, MA.
Industrial Fabrics Association International, St. Paul, MN. Vol 2, p 645-650.
                                             38

-------
Evett, S., 2000. Some aspects of time domain reflectometry (TDR), neutron scattering, and capacitance
methods of soil water content and measurement. In Comparison of Soil Water Measurement Using the
Neutron Scattering, Time Domain Reflectometry and Capacitance Methods. International Atomic Energy
Agency, Vienna, Austria, IAEA-TECDOC-1137, p 5-49.
http://www.cprl.ars.usda.gov/programs/pdfs/IAEAEVET.PDF

Frangos, W., 1997. Electrical detection of leaks in lined waste disposal ponds. Geophysics, Vol. 62, No. 6
(November-December 1997), p 1737-1744.

G2 Imaging, undated. Heap Leach Pad Monitoring to Manage Risks in Gold and Copper Mining.
TerraPlus, Inc. Littleton, CO. http://www.terraplus.com/papers/g2%20Imaging.com.

Gray, W., L. Everett, and S. Cullen (eds.), 1995. Handbook ofVadose Zone Characterization &
Monitoring, CRC Press, Boca Raton, FL.

Hassoun, S., T. McBride, and D. Russell, 2000. Development of perfluorocarbon tracer technology for
underground leak location. Journal of Environmental Monitoring, Vol 2 No 5, p 432-435, Oct 2000.

Hubbell, J. and J. Sisson, 1998. Advanced tensiometer for shallow or deep soil water potential
measurements. Soil Science, 163(4) p 271-276.

Laine, D., A. Binley, and G. Darilek, 1997a. Locating geomembrane liner leaks  under waste in a landfill.
Geosynthetics '97 Conference Proceedings, Long Beach California, U.S.A., March 11-13,1997. Industrial
Fabrics Association International, St. Paul, MN. p 407-411.

Laine, D., A. Binley, and G. Darilek, 1997b. How to locate liner leaks under waste. Geotechnical Fabrics
Report, Aug 1997.

Laine, D. and G. Darilek, 1993. Locating leaks  in geomembrane liners of landfills covered with a protective
soil. Geosynthetics '93 Conference Proceedings, Vancouver, British Columbia, Canada, March 30 - April 1,
1993.

Looney, B. and R. Falta (eds.), 2002. Vadose Zone Science and Technology Solutions. Battelle Press,
Columbus, OH.

Parasnis, D., 1997. Principles of Applied Geophysics. Chapman & Hall, London.

Peggs, I.D. and S. McLaren, 2002. Portable infrared spectroscopy for the rapid monitoring of leaks in
landfill caps and bottom geomembrane liners. Proceedings 7ICG September 2002, Swets & Zeitlinger,
Lisse, The Netherlands, p 775-778.

Peggs, I.D., 2001. Three challenging electrical integrity/leak surveys on uncovered and deep waste-covered
liners. Proceedings of Geosynthetics Conference 2001, IFAI, Roseville, MN, p 245-262.

Phaneuf, R.J. and I. Peggs, 2001. Landfill construction quality- lessons learned  from electrical resistivity
testing of geomembrane liners. In Geotechnical Fabrics Report (GFR), IFAI, Roseville, MN, April 2001, p
28-35.

Peggs, L, 1999. Geomembrane Liner Integrity Survey Technologies and Their Findings. I-Corp
International, Inc. 11 pp.

-------
 Rodel, A., 1996. GEOLOGGER: A new type of monitoring system for the total area monitoring of seals on
 landfill sites. Geosynthetics: Applications, Design and Construction. Proceedings of the First European
 Geosynthetics Conference, Maastricht, 1996. p 625-626.

 Rouessac, F. and A. Rouessac, 2000. Chemical Analysis: Modern Instrumental Methods and Techniques.
 John Wiley & Sons, West Sussex, UK.

 Siemens, A.G., 1998. Leos® Leak Detection and Location System. Erlangen, Germany, 7 pp.
 http://www.de.framatome-anp.eom/anp/e/foa/anp/products/a-z/leose.pdf

 Sisson, J. B., G.W. Gee, et al., 2002. Advances in tensiometry for long-term monitoring of soil water
 pressures. Vadose Zone Journal 1: p 310-315.

 Staller, G. and R. Wemple, 1996. Geomembrane Barriers Using Integral Fiber Optics to Monitor Barrier
 Integrity. Sandia Corp., Albuquerque, MM. Patent No.: US 5567932 A.  10 pp, 22 Oct 1996.

 Stormont, J., M. Ankeny, and J. Kelsey, 1998. Airflow as monitoring technique for landfill liners. Journal
 of Environmental Engineering (New York), Vol 124 No 6, p 539-544, 30 Jun 1998.

 Studer, J., 2000. The vadose zone monitoring system for the CAMU project at Sandia National
 Laboratories. Vadose Zone Science and Technology Solutions. Battelle Press, Columbus, OH.

 Swyka, M. and I. Peggs, 1999. Overview of landfill liner leak location technologies. WasteCon '99,
 February 1999, New Orleans, Louisiana.

 U.S. DoD, 2000. Cost and Performance Report- Elecromagnetic Surveys for 3-d Imaging  of Subsurface
 Contaminants. Environmental Security Technology Certification Program, Department of Defense.

 U.S. DOE, 2000. Innovative  Technology Summary Report: Subsurface Barrier Verification with the
 Seatrace™ Monitoring System, DOE/EM-0549. Subsurface Contaminants Focus Area and
 Characterization, Monitoring, and Sensor Technology Crosscuttmg Program.

 U.S. DOE, 2002. Innovative  Technology Summary Report: Advanced Tensiometerfor Vadose Zone
 Monitoring,  DOE/EM-0639. Subsurface Contaminants Focus Area and Characterization, Monitoring, and
 Sensor Technology Crosscutting Program.  http://apps.em.doe.gov/OST/pubs/itsrs/itsr2122.pdf

 U.S. DOE, 2003. Geophysical monitoring system installed on EPA's Gilt Edge Superfund  Site
 INEEL Subsurface Science Initiatives Newsletter, Vol 4 No 1, Mar 2003.
 http://subsurface.inel.gov/information/newsletter/Vol4Issl/giltedge.asp

 U.S. EPA, 1983. Standardized Procedures for Planting Vegetation on Completed Sanitary Landfills, EPA
 600/2-83/055.

 U.S. EPA, 1985a. Covers for Uncontrolled Hazardous Waste Sites, EPA 540/2-85/002.

 U.S. EPA, 1985b. Settlement and Cover Subsidence of Hazardous Waste Landfills, EPA 600/2-85/035.

 U.S. EPA, 1987a. Engineering Guidance for the Design, Construction, and Maintenance of Cover Systems
for Hazardous Waste, EPA 600/2-87/039.
                                             40

-------
U.S. EPA, 1987b. Prediction/Mitigation of Subsidence Damage to Hazardous Waste Landfill Covers, EPA
600/2-87/025.

U.S. EPA, 1989a. Final Covers on Hazardous Waste Landfills and Surface Impoundments, EPA
530/SW-89/047.

U.S. EPA, 1989b. RCRA ARARs: Focus on Closure Requirements, OSWER Directive 9234.2-04FS.

U.S. EPA, 1991a. Conducting Remedial Investigations/Feasibility Studies for CERCLA Municipal Landfill
U.S. EPA, 1991b. Seminar Publication: Design and Construction of RCRA/CERCLA Final Covers, EPA
625/4-91/025.

U.S. EPA, 1993a. Solid Waste Disposal Facility Criteria: Technical Manual, EPA/530/R-93/017.

U.S. EPA, 1993b. Subsurface Characterization and Monitoring Techniques, A Desk Reference Guide.
Volume II: The Vadose Zone, Field Screening and Analytical Methods Appendices C and D. EPA/625/R-
93/003b.

U.S. EPA, 1993c. Technical Guidance Document: Quality Assurance and Quality Control for Waste
Containment Facilities. EPA/600/R-93/182.

U.S. EPA, 1994. Seminar Publication: Design, Operation, and Closure of Solid Waste Landfills,
EPA/625/R-94/008.

U.S. EPA, 1995. Presumptive Remedies: CERCLA Landfill Caps RI/FS Data Collection Guide, EPA
540/F-95/009.

U.S. EPA, 1998a. Evaluation of Subsurface Engineered Barriers at Waste Sites. EPA/542/R-98/005.

U.S. EPA, 1998b. Evaluation of Subsurface Engineered Barriers at Waste Sites, Volume II, Appendix B.
EPA/542/R-98/005a.

U.S. EPA, 1999. Compendium of Methods for the Determination of Toxic Organic Compounds in Ambient
Air, Compendium Method TO-16, Long-Path Open-Path Fourier Transform Infrared Monitoring of
Atmospheric Gases. EPA/625/R-96/10b.

U.S. EPA, 2002. Assessment and Recommendations for Improving the Performance of Waste Containment
Systems, EPA/600/R-02/099.

U.S. EPA, 2004. Research and Development: Measurement of Fugitive Emissions at Region I Landfill,
EPA/600/R-04/001.

Versteeg, R., G. Heath, et al., 2003. Electrical resistance tomography to monitor mitigation of metal-toxic
acid-leachates ruby gulch waste rock Repository Gilt Edge Mine Superfund site, South Dakota, USA. 2003
AGU meeting, San Francisco, EOS Trans. AGU, 84(46), Fall Meet. Suppl, Abstract H31B-0471, 2003.
                                            41

-------
Versteeg, R., G. Heath, et al., 2003. Design and installation of a remotely controllable autonomous
resistivity monitoring system at the Gilt Edge Mine superfund site, South Dakota. SEG Annual Meeting,
Dallas, TX. Society of Exploration Physicists.

White, C. and R. Barker, 1997. Electrical leak detection system for landfill liners: a case history. Ground
Water Monitoring and Remediation, Vol. 17, No. 3 Summer 1997, p 153-159.
                                               42

-------
                                         APPENDIX A

                                           Glossary

 Capacitance sensor. An instrument used to measure the difference in electric potential between two points
      in the soil. This data is then used to determine the amount of water in the soil.

 Capillary zone: The area immediately above the saturated zone where water is drawn up into pores by
      capillary pressure.

 Dielectric: The ability of a dielectric to store electrical potential energy under the influence of an electric
      field measured by the ratio of the capacitance of a condenser with the material as dielectric to its
      capacitance with vacuum as dielectric.

 Field capacity: The quantity of water that can be held by soil against the pull of gravity.

 Gypsum block: A cylindrical block  of calcium sulfate (CaSO4) into which two electrodes are inserted. The
      block is porous and allows water to move in and out as the soil wets and dries. In the presence of
      moisture the CaSO4 goes into solution allowing ion movement between the two electrodes. The
      current can be measured and is  directly related to soil moisture content.

 Heap leaching: A method for extracting precious metals from low grade ores where the ore is placed in a
      pile and a leaching solution, usually cyanide, is poured over it and then recovered.

 Hydraulic conductivity: A coefficient of proportionality describing the rate at which water can move
      through a permeable medium. Hydraulic conductivity is a function of both the intrinsic permeability
      of the porous medium and the kinematic viscosity of the water that flows through it. In older
      documents, hydraulic conductivity is  referred to as the coefficient of permeability.

 Impedance: A material's opposition to the flow of electrical current.

 Permeability: The capacity of a soil to transmit a fluid.

Permeameter: An instrument used to measure the permeability of a soil.

Soil water potential: The amount of work needed, per unit quantity of pure water, to transport the pure
      water from the reference state to the state in question, reversibly and isothermally.

Suction lysimeter: A device for collecting pore water from soils. Usually consisting of a ceramic cup,
     reservoir, and collection tube.

Time domain reflectrometry: The measurement of an electromagnetic pulse sent down a coaxial cable to
     detect an impedance change or discontinuity.
                                               A-l

-------
Vadose zone: The area in the subsurface that lies between the ground surface and the capillary zone.

Water balance: Evapotranspiration study that shows the fate of water that is applied to an area (e.g., how
      much is used by vegetation, evaporates, or infiltrates).

Wicking: The process of pulling a liquid into a material using differential potential pressures.
                                               A-2

-------
                                    APPENDIX B1


                    List of Contacts, Vendors, and Products

Advanced Tensiometer

In-Situ Inc.
P.O. Box I
210 S. Third Street
Laramie, WY 82073 USA
Phone:(307)742-8213
Fax:(307)721-7598
Website: http://www.in-situ.com

North Wind Environmental, Inc.
P.O. Box 51174
Idaho Falls, ID 83402
Phone:(208)528-8718
Fax:(208)528-8714
Website: http://www.nwindenv.com

Chemical Fiber Optic Leak Detection

DecisionLink, Inc.
1181GrierDr.,BldgB
Las Vegas, NV 89119
Phone: (702) 361-3027
Fax:(702)361-9652

Diffusion Hose

Siemens AG
Bereich Power Generation
KWUNW-D
Freyeslebenstr. 1
P.O. Box 3220
D-91058Erlangen
Phone: (09131)  18-3615 or 18-5043
Website: http://www.siemens.com
        1 This list of vendors is not meant to be comprehensive and was developed from either their
 mention in the literature or websites that provided descriptions of devices that may be applicable to
 monitoring liners or covers. Mention of trade names or commercial products does not constitute
 endorsement or recommendation for use.


                                          B-l

-------
Electrical Grid Systems

Forschungszentrum Karlsruhe
Postfach 3640
D-76021 Karlsruhe, Germany
Dr. Alexander Brandelik
Phone: 49 (0) 7247-823913

SENSOR International Environmental Protection
11 Avenue de la Liberte - L 1931 - Luxembourg
Phone: 352 489 921
Fax : (352) 2629 6328
Email: sensor@sensoriep.com

SRK Consulting
Suite 115
3275 West InaRd.
Tucson, AZ 85741
Phone: (520) 544-3688
Fax: (520) 544-9853
Website: http://www.na.srk.com/

Electrochemical Sensing Wire Cable

Tyco Thermal Controls LLC
300 Constitution Dr.
Menlo Park, CA 94025-1164
Tel (800) 545-6258 (within U.S. only)
Tel (650) 216-1526 (outside U.S.)
Fax (800) 527-5703
Website: http://www.tycothermal.com/northamerica/english/leakdetection/default.asp

Lysimeters

Soilmoisture Equipment, Corp.
P.O. Box 30025
Santa Barbara, CA 93105
Phone: (805) 964-3525
Fax: (805) 683-2189
Website: http://soihnoisture.com
                                            B-2

-------
Moisture Capacitance Instruments

Troxler Electronic Laboratories, Inc.
P.O. Box 12057
3008 Cornwallis Rd.
Research Triangle Park, NC 27709
Phone: (919) 549-8661
Fax: (919) 549-0761
Website: http://www.troxlerlabs.com/PRODUCTS/fieldequip.html

Neutron Probes

CPN International, Inc.
2830 Howe Road
Martinez, CA 94553
Phone: 925-228-9770
Fax: 925-228-3183
Toll Free: 800-468-4276
Website: http://www.cpn-intl.com

Portable Electric Systems

I-CORP International, Inc.
6072 N. Ocean Blvd.
Ocean Ridge, FL 33435
Phone: (561) 369-0795
Fax: (561) 369-0895
Website: http://www.geosynthetic.com

Leak Location Services, Inc.
16124 University Oak
San Antonio, TX 78249
Phone:(210)408-1241
Fax:(210)408-1242
Website: http://www.llsi.com

Soil Gas

Tracer Research Corporation
3755 North Business Center Drive
Tucson, AZ 85705-2944
Phone:  (800) 394-9929
Fax:  (520) 293-1306
Website: http://www.tracertight.com
                                            B-3

-------
Time Domain Reflectometry Probes

Dynamax, Inc.
10808 Fallstone Suite 350
Houston, TX 77099
Phone:(281)564-5100
Fax:(281)564-5200
Website: http://www.dynamax.com

Soilmoisture Equipment, Inc.
P.O. Box 30025
Santa Barbara, CA 93105
Phone: (805) 964-3525
Fax: (805) 683-2189
Website: http://soilmoisture.com

Campbell Scientific, Inc.