United States            Office of Water (4303)              EPA-XXX-X-99-XXX
   Environmental Protection      Washington, DC 20460             January 1999
   Agency	


         Protocol for EPA Approval of New Methods or

         Alternate Test Procedures for Whole Effluent

         Toxicity
/~)

ir

-------
          Protocol for EPA Approval
of New Methods or Alternate Test Procedures
          for Whole Effluent Toxicity
                    January 1999
             Engineering and Analysis Division
             Office of Science and Technology
                   Office of Water
           U.S. Environmental Protection Agency
                   Washington, D.C.

-------
Approval of New Methods and A TPs for Whole Effluent Toxicity
                                           Foreword

       Within the U.S. Environmental Protection Agency's (EPA) Office of Water (OW), the Office of
Science and Technology (OST) has responsibility for administering the Clean Water Act (CWA) Section
304(h) Method Approval Program. The Method Approval Program entails proposal and promulgation of
chemical and biological methods at 40 Code of Federal Regulations (CFR) part 136 for use in National
Pollutant Discharage Elimination System (NPDES) data gathering and compliance monitoring under the
CWA. In 1995, program administration was transferred from EPA's Office of Research and Development
(ORD)-National Exposure Research Laboratory (NERL) in Cincinnati to OST to centralize the overall
responsibility for promulgating effluent guidelines and associated compliance monitoring methods, with the
intent of expediting the method approval process. Within OST, the Analytical Methods Staff (AMS)  was
delegated responsibility for administering the Method Approval Program. This responsibility includes  the
review and recommendation for approval of new test methods and alternate test procedures (ATPs)  within
approved methods.

       Approval to modify an EPA-approved method can be gained through the ATP process specified at
40 CFR 136.4 and 136.5. To implement the ATP program, EPA developed guidelines for submission and
review of ATP applications for chemical methods and selected microbiological methods approved at 40 CFR
part 136.  In 1995, EPA promulgated a series of whole effluent toxicity (WET) test methods at 40 CFR part
136.3, Table 1A. The EPA-approved WET methods employ standardized aquatic test organisms to directly
measure the aggregate toxicity of effluents and receiving waters. This draft protocol provides guidance for
validating and submitting an application for approval of a new WET method and  approval of an alternate test
procedure or modification within an Agency-approved WET method. In preparing this guidance, AMS
revised a draft WET ATP document developed by ORD to incorporate literature research on alternate
analytical methods, internal EPA comments, critiques by members of EPA's Biological Advisory Committee
(BAG), and external expert review comments to develop the current protocol.

       This document gives specific instructions to  external organizations regarding the validation,
submission, and EPA approval of applications for new methods and ATPs that determine whole effluent
toxicity. As it applies to modifications to approved WET methods, this document should serve as a
supplement to the existing ATP guidance at 40 CFR 136.4 and 136.5. Due to the inherent complexity of the
review of new methods, EPA will apply the concepts introduced in this protocol for the review of new WET
methods on a case-by-case basis. EPA anticipates that the standardized procedures described herein should
expedite the approval of WET methods, encourage the development of innovative technologies for measuring
WET, and enhance the overall utility of the EPA methods approved for NPDES compliance monitoring.

       This document is not a legal instrument and  does not establish or affect legal obligations under
Federal regulations. EPA reserves the right to change this protocol without prior notice.

       All questions regarding the guidelines presented in this protocol should be directed to:

       William A. Telliard
       Director, Analytical Methods Staff
       Engineering and Analysis Division (4303)
       U.S. EPA Office of Water
       401 M Street,  S.W.
       Washington, DC 20460

                                                ii

-------
                                                Approval of New Methods and ATPs for Whole Effluent Toxicity
                                     Table Of Contents

1.0    INTRODUCTION AND BACKGROUND  		1
       1.1     Regulatory Background and Objectives	1
       1.2     Approved Whole Effluent Toxicity Test Methods	2
       1.3     Acute and Short-Term Chronic Whole Effluent Toxicity Tests	5
       1.4     Definitions of "New Methods" and "Alternate Test Procedures"	6
               1.4.1 New Methods 	fi
               1.4.2 Alternate Test Procedures	6
       1.5     Precision and Sensitivity in WET Test Data  	7
       1.6     Use of Resident Species	8

2.0    APPLICATION REQUIREMENTS	9
       2.1     Submission Addresses and Approval Authority	9
       2.2     Application Information	11
       2.3     Standard EPA Method Format  	12
       2.4     Method Comparison Table	13
       2.5     Validation Study Plan	13
       2.6     Validation Study Report	13
       2.7     Documentation to Facilitate EPA Rulemaking	14
       2.8     Proprietary Information in Applications	J4

3.0    METHOD VALIDATION	16
       3.1     Introduction  	16
       3.2     Tiered Validation System For Proposed WET Methods	17
               3.2.1 Tier 1 Validation Studies	18
               3.2.2 Tier 2 Validation Studies	18
               3.2.3 Tier 3 Validation Studies	18
       3.3     Summary of Tier 1, 2, and 3 Validation Requirements for WET Methods	19
       3.4     Specific Validation Requirements for New Methods and Alternate Test Procedures  . . 22
               3.4.1 Distribution of Method and Validation Study Plan	22
               3.4.2 Side-by-Side Tests	22
               3.4.3 Replicate Testing	22
               3.4.4 Matrix Types  	23
               3.4.5 Reference Toxicants 	23
               3.4.6 Selection and Use of Test Species   	23
               3.4.7 Replicate Chambers Per Concentration	24
               3.4.8 Acute Tests - Sample Concentration Series  	24
               3.4.9 Short-Term Chronic Tests - Sample Concentration Series	25
               3.4.10 Preliminary Toxicity Range-Finding Tests  	25
               3.4.11 Quality Assurance and Quality Control   	25
               3.4.12 Data Collection and Recording	25
               3.4.13 Physical and Chemical Parameters and Test Acceptability Criteria	26
               3.4.14 Raw Data Analysis - Determination of Test Endpoints	26
               3.4.15 Statistical Analysis of Endpoints - Determination of Sensitivity and Precision  . . 26

                                               iii

-------
Approval of New Methods and ATPs for Whole Effluent Toxicity
       3.5     Selection of Laboratories to Participate in the Validation Study  	27
       3.6     Validation Study Plan 	29
              3.6.1 Background	29
              3.6.2 Objectives	29
              3.6.3 Study Management  	29
              3.6.4 Technical Approach	29
              3.6.5 Data Reporting and Evaluation	3_Q
              3.6.6 Limitations	3J)
       3.7     Validation Study Report	3_Q
              3.7.1 Background	3_Q
              3.7.2 Study Design and Objectives  	3J.
              3.7.3 Study Implementation	3J.
              3.7.4 Data Reporting and Validation 	3J.
              3.7.5 Results  	32
              3.7.6 Data Analysis/Calculation	32
              3.7.7 Conclusions	32
              3.7.8 Appendix A - The Method	32
              3.7.9 Appendix B -Validation Study Plan	22
              3.7.10 Appendix C - Supporting Data  	3.2

4.0    EPA REVIEW AND APPROVAL  	3j4
       4.1     EPA Review of New Method and ATP Applications  	3_4
       4.2     Approval Recommendation	3_6
       4.3     Rulemaking Process	3.6

5.0    REFERENCES  	3.8

6.0    APPENDIX A - APPLICATION FORM	40

7.0    APPENDIX B - REGIONAL ATP CONTACTS  	41

8.0    APPENDIX C - STANDARD EPA EMMC FORMAT FOR WET METHODS  	42

9.0    APPENDIX D - LIST OF STANDARD REFERENCE TOXICANTS	44
                                            IV

-------
                                                Approval of New Methods and ATPs for Whole Effluent Toxicity
1.0   INTRODUCTION AND BACKGROUND

1.1    Regulatory Background and Objectives

       The Clean Water Act (CWA) requires the U.S. Environmental Protection Agency (EPA) to
promulgate guidelines establishing test procedures for data gathering and compliance monitoring under
National Pollution Discharge Elimination System (NPDES) permits. Within EPA, the Office of Water
(O W) publishes test procedures for the analysis of wastewater. These test procedures are specified at 40
part 136 of the Code of Federal Regulations (CFR) (USGPO, 1996 and FWCA, 1987). On October 16,
1995, EPA promulgated a final regulation approving the use of whole effluent toxicity (WET) test
methods to protect aquatic life in NPDES compliance monitoring (60 FR 53529). Whole effluent toxicity is
defined as the aggregate toxic effect of an effluent or receiving water measured directly with a toxicity
test. The Agency-approved WET test methods are listed at 40 CFR §136.3, Table IA (USEPA, 1994a,
1994b, and 1993a). These WET methods employ standardized aquatic test species to directly measure the
acute or short-term chronic adverse effects of effluents and receiving waters in NPDES biomonitoring.

       WET is considered a "method-defined analyte," which is an analyte that does not have a specific,
known composition, therefore, the analytical result is dependent on the measurement technique. As a
result, a change in the analytical technique has the potential to change the numerical value of the sample
result. EPA believes that modifications to test procedures that determine method-defined analytes will
need to have less flexibility than is allowed for methods that determine individual chemical or biological
analytes. Therefore, EPA is restricting the allowable flexibility in methods for method-defined analytes
and has established more stringent, standardized requirements for demonstrating the acceptability of new
methods and alternate test procedures for EPA approval (USEPA, 1996a).

       The objective of this protocol is to provide guidance to external organizations regarding
preparation and submission of applications for formal EPA approval of new methods or alternate WET
test procedures for use in the NPDES program. This document serves as a supplement to the alternate
test procedure (ATP) guidelines published at 40 CFR §136.4 and 136.5. The codified ATP guidelines
allow entities to apply for approval to modify an EPA-approved method. Due to the inherent complexity
of evaluating new technologies for measuring WET  and the fact that guidelines for the approval of new
methods are being introduced in this document, EPA will apply the concepts in this protocol for the review
of new WET method applications on a case-by-case basis.

       Using this protocol, new methods or alternate WET test procedures may be developed and
validated using the "tiered" validation procedures delineated in this document. Method validation is the
process that establishes the performance of new methods or substantiates  the  performance of an ATP.
Under the  tiered system, a proposed WET method is classified based on its intended use,  and a method
validation  study is required that reflects the level of use associated with each of three tier levels. At Tier
1, methods that are proposed for limited use (LU)  in a single "matrix type" (e.g., field collected effluent
from a single industrial subcategory) or multiple matrix types may  be validated through a single-laboratory
validation  study, without the burden of conducting an interlaboratory (multi-laboratory) study. Methods
intended for nationwide use (NW) in a single matrix type (Tier 2) or all matrix types (Tier 3), require
interlaboratory testing. The validation data and other supporting documentation must then  be submitted to
EPA as a part of a formal new method or ATP application to request approval. Based on the
                                                                                 January 1999

-------
Approval of New Methods and ATPs for Whole Effluent Toxicity
intended level of use, the application must be submitted to the state permitting agency, EPA Region, or
EPA's Analytical Methods Staff (AMS) for internal review. The appropriate agency will review the
submission and assess the performance and applicability of the proposed WET method for use in NPDES
compliance monitoring. Proposed methods submitted for limited use will be formally approved by the
Regional Administrator or state agency through a "letter of approval", while nationwide applications are
officially approved by the EPA Administrator through rulemaking.

        The standardized application and validation procedures described in this protocol are intended to
accelerate the method approval process and encourage the development of innovative technologies for
measuring whole effluent toxicity. Ideally, proposed WET test methods should include one or more of the
following: advances in test species culturing, test procedures, and test concepts; improved data collection
and analysis techniques;  reduced test complexity; reduced analytical costs; enhanced method
performance (sensitivity  and/or precision); increased ecological relevance; and  heightened protection of
aquatic life in receiving waters. EPA believes that submissions that meet the requirements for approval
described in this protocol and incorporate any of the above attributes will enhance the utility of the WET
methods approved for use in the NPDES program.

1.2     Approved Whole Effluent Toxicity Test Methods

        The WET test procedures currently approved by EPA employ a suite of standardized, surrogate
freshwater, marine, and estuarine plants, invertebrates, and vertebrates to measure acute and estimate
chronic toxicity. Surrogate species are test organisms that can be studied to produce results to estimate
toxic responses of other  species that are not tested directly. The test species in the EPA-approved WET
methods were chosen because as a group they are readily cultured or maintained in the laboratory, they
are available in the appropriate life-stages throughout the year from commercial sources in sufficient
quantity and quality  for testing purposes, they are relatively inexpensive since they may be cultured year-
round in the lab, their reliability for use in toxicity testing is better established than  for other species, they
are better integrated  into  Toxicity Identification Evaluations (TIEs), and they span the sensitivity range of
species of the ecosystems studied (USEPA, 1991a and ASTM, 1998). A list of the EPA WET methods
approved at 40 CFR 136.3, Table IA is provided in Table 1. The methods are published in the following
documents:

•       Methods for Measuring the Acute Toxicity of Effluents and Receiving Waters to Freshwater
        and Marine Organisms, Fourth Edition, EPA-600-4-90-027F, August 1993 (USEPA, 1993a).

•       Short-Term Methods for Estimating the Chronic Toxicity of Effluents and Receiving Water
        to Freshwater Organisms, Third Edition,  EPA-600-4-91-002, July 1994 (USEPA, 1994a).

•       Short-Term Methods for Estimating the Chronic Toxicity of Effluents and Receiving Water
        to Marine and Estuarine Organisms, Second Edition, EPA-600-4-91-003, July 1994 (USEPA,
        1994b).

        These documents are referred to collectively throughout this document as the "EPA WET
        methods manuals".

        The approved marine chronic methods do not apply to discharges into marine waters of the
Pacific Ocean. EPA intends to propose approval of marine chronic methods applicable to the colder,

                                               2                                  January 1999

-------
                                                  Approval of New Methods and A TPsfor Whole Effluent Toxicity
Pacific coast waters. However, test species are included in the acute WET methods manual that are
applicable to west coast waters.
                                                                                   January 1999

-------
Approval of New Methods and ATPs for Whole Effluent Toxicity
                  Table 1: EPA-Approved Whole Effluent Toxicity Methods
Water Matrix
Test Organism
Scientific Name
Test Duration Endpoint
Acute Toxicity Tests* [USEPA, 1993a]
Freshwater
Marine and Estuarine
Cladoceran
Fathead minnow
Rainbow trout
Brook trout
Mysid shrimp
Sheepshead minnow
Silverside
Ceriodaphnia dubia
Daphnia magna
Daphnia pulex
Pimephales promelas
Oncorhynchus mykiss
Salvelinus fontinalis
Mysidopsis hahia
Holmesimysis costata
Cyprinodon variegatus
Menidia beryllina
Menidia mendia
Menidia peninsulae
24, 48, optional 96 h
24, 48, optional 96 h
24, 48, optional 96 h
24,48, 96 h
24,48, 96 h
24, 48, 96 h
24,48, 96 h
24, 48, 96 h
24,48, 96 h
24,48, 96 h
24,48, 96 h
24,48, 96 h
Mortality
Mortality
Mortality
Mortality
Mortality
Mortality
Mortality
Mortality
Mortality
Mortality
Mortality
Mortality
Short-Term Chronic Toxicity Tests - Freshwater [USEPA, 1994b]
Freshwater
Cladoceran
Fathead minnow
Fathead minnow
Green alga
Ceriodaphnia dubia
Pimephales promelas
Pimephales promelas
Selenastrum
capricornutum
60% of controls have
3 broods (7 days)
7 days
7-9 days
96 h
Survival and
Reproduction
Larval Survival and
Growth
Embryo-larval Survival
and Teratogenicity
Growth
Short-Term Chronic Toxicity Tests - Estuarine and Marine [USEPA, I994a]
Marine and Estuarine
Mysid
Sea urchin
Sheepshead minnow
Sheepshead minnow
Inland Silverside
Red Macroalga
Mysidopsis bahia
Arbacia punctulata
Cyprinodon variegatus
Cyprinodon variegatus
Menedia beryillina
Champia parvula
7 days
1.5 h
7 days
7-9 days
7 days
7-9 days
Survival, Growth, and
Fecundity
Fertilization
Larval Survival and
Growth
Embyro-larval Survival
& Teratogenicity
Larval Survival and
Growth
Reproduction
(Cystocarp production)
 : A supplemental list of EPA-approved acute test species is included on pp. 264-266 of USEPA, 1993a.
                                                                                   January 1999

-------
                                                  Approval of New Methods and A TPsfor Whole Effluent Toxicity
1.3     Acute and Short-Term Chronic Whole Effluent Toxicity Tests

        Both acute and short-term chronic WET tests are approved by EPA. Acute WET tests determine
the concentration of water sample (e.g., effluent, receiving water, reference toxicant) that produces an
adverse effect on a group of test organisms during either a 24, 48, or 96 hour exposure. Acute test
endpoints include the following:

        (1)     Lethal Concentration or Effect Concentration (LC or EC)- a point estimate of the water
               sample concentration that causes death or other adverse biological effect in a specified
               percentage (LCP or ECP) of the  exposed test species within a selected exposure period.
               The most common acute value reported is the LC50.
        (2)     No Observed Adverse Effect Concentration (NOAEC) - the highest concentration of
               water sample at which survival is not significantly different from control.
        (3)     Pass/Fail Test - determines whether the survival of test species in the water sample is
               significantly less than survival in control.

        Short-term chronic WET tests estimate chronic toxicity by evaluating, in addition to mortality, the
sublethal effects of water samples, such as suppression of growth or length, or impairment of
reproduction, fertilization, or larval development. A chronic effect is a stimulus from exposure to a
toxicant that lingers or continues for a relatively long period of time. Traditionally, a chronic test is either a
full-life cycle test or a shortened test of about 30 days known as an early life stage test. Because of the
high cost and time required for these classical chronic toxicity tests, short-term chronic tests that focus on
the critical life stage have been developed for use in compliance  monitoring. The critical life stage  is the
period of time in an organism's lifespan in which it is the most susceptible to adverse effects caused by
exposure to toxicants. The EPA-approved short-term chronic tests range from 40 minutes to 7 days of
exposure. Short-term chronic test endpoints include:

        (1)     No Observed Effect Concentration (NOEO - the highest concentration of water  sample
               in which the observed responses are not statistically different from the control response.
        (2)     Lowest Observed Effect Concentration (LOEC) - the lowest concentration of water
               sample in which the observed responses are statistically different from the control
               response.
        (3)     Lethal Concentration (LC) - defined above.
        (4)     Effective Concentration (EC) - a point estimate of the water sample concentration that
               produces an observable effect on an all or nothing response (e.g., death, immobilization).
        (5)     Inhibition Concentration (1C) - a point estimate of the water sample concentration that
               produces a given reduction (e.g., 25%, 50%) in survival, fecundity, or growth.
        (6)     Pass/Fail test - a determination of whether the specified response in a water sample is
               statistically different from the control response.

        A variety of statistical methods are used to generate and interpret the data generated in the tests
described above. The LC, EC, and 1C WET endpoints are determined using point estimate techniques.
Point estimate techniques are statistical analyses that determine  the test sample concentration at which a
given adverse effect level occurred. These statistical techniques include the Graphical, Spearman-

                                                5                                  January 1999

-------
Approval of New Methods and A TPs for Whole Effluent Toxicity
Karber, Trimmed Spearman-Karber, or Probit Method. The NOAEC, NOEC, LOEC, and pass/fail
endpoints are determined using hypothesis testing. Hypothesis testing determines the test sample
concentration in which the observed responses are statistically different from the control responses.
Additional terminology pertinent to statistical procedures used to generate toxicity endpoints is included in
the EPA WET methods manuals and the EPA Technical Support Document For Water Quality-based
Toxics Control or "TSD" (USEPA, 1994a, 1994b, 1993a, and 199la).

1.4    Definitions of "New Methods" and  "Alternate Test Procedures"

       A proposed WET test procedure will be considered either a new method or an ATP, according to
the following criteria.

1.4.1  New Methods

       A proposed test procedure will be considered a new method if it employs a test species, an
endpoint or organism response,  or a toxicity test concept that is not represented in the battery of Agency-
approved WET methods. Since  WET is a method-defined analyte, EPA generally considers the use of
new test species, endpoints, or test concepts to be substantial changes, and therefore will be approved as
new methods. The applicability  and performance (sensitivity and precision) of new methods for NPDES
compliance monitoring will be compared to the approved WET tests and considered for promulgation at
40 CFR part 136 on a case-by-case basis. Performance of WET methods is further discussed in Section
1.5 and the selection and use of resident species in WET testing is discussed in Section 1.6. The specific
requirements for validating new WET methods are outlined in Section 3.0.

Note:  Performance data for  the EPA-approved WET methods are included in the EPA WET
       methods manuals and the TSD (USEPA, 1994a, 1994b,  1993a, and 199la).

1.4.2  Alternate Test Procedures

       A proposed test procedure will be considered an alternate test procedure if it involves a
modification to selected attributes (i.e. test conditions) of the Agency-approved method.  A proposed
method that uses a subspecies, a species that has similar phylogeny (evolutionary history), or a species
that occupies the same feeding guild as the Agency-approved species, may be considered for approval as
an ATP. As is the case with all method-defined analytes, modifications to WET methods must be
carefully considered to guard against changes that will significantly alter the results of the test. Strict
review of validation data will ensure that only acceptable ATPs are approved. EPA expects that ATPs
may incorporate, but are not limited to, changes to the following aspects of an approved WET method:

•     Sample collection, holding time, and handling
•     Test type (i.e., static, static-renewal, flow-through)
•     Type and size of test chamber and sample delivery system
•     Test sample volume and  renewal scheme
•     Dilution water
•     Test species age (life-stage) and loading density in test chambers
•     Test species culturing protocols
•     Test conditions (i.e, lighting, type and quantity of food)
•     Test concentrations, dilution factor, and/or number of replicate chambers/concentration

                                               6                                 January 1999

-------
                                                  Approval of New Methods and ATPs for Whole Effluent Toxicity
•     Method of data analysis

      To be considered for approval, ATPs must meet the physical and chemical parameters and test
acceptability criteria of the approved method and demonstrate precision and sensitivity equal to or greater
than that demonstrated by the unmodified Agency-approved test procedure in side-by-side tests. Precision
and sensitivity in WET methods is further discussed in Section 1.5. The specific requirements for
validating a WET ATP are outlined in Section 3.0.

1.5   Precision and Sensitivity in WET Test Data

      Sensitivity and precision are attributes of WET test data that allow for the assessment of method
performance. In toxicity tests, the "detection limit" is determined by the sensitivity of the test organisms.
Sensitivity is defined as the capability of a method to differentiate between different concentrations of an
analyte (USEPA, 1996a). In relation to WET testing, sensitivity is the degree of response of a given test
species to different types (i.e, salts, metals, organics, effluents, and freshwater, marine, and estuarine
receiving waters) and concentrations of test samples. Precision is defined  as a measure of mutual
agreement among individual measurements or enumerated values of the same property of a sample
(USEPA, 1996a). Precision is described by the mean,  standard deviation, or relative standard deviation
(coefficient of variation) of a given set of data.

      The sensitivity of organisms to toxicants is an intrinsic quality, which may vary greatly between
species, but also varies somewhat between organisms within the same species. The range of acute and/or
chronic response exhibited by the least sensitive and most sensitive species across widely separated
taxonomic groups exposed to the same toxicant may differ by several orders of magnitude. In addition, a
given species that is relatively insensitive to one  compound (e.g. a metals)  may be very sensitive to a
different compound (e.g. a pesticide). Studies observing test species response to a wide variety  of whole
effluents and pure compounds have  shown that no  organism or test method is always the most sensitive
(USEPA, 199 la). The sensitivity of test species employed by a given method will depend on the
characteristics of the test sample, the age and condition (health) of the organisms, and  test conditions  such
as light quality, intensity, and photoperiod; water temperature, salinity, pH, alkalinity, and hardness; the
size of the test chambers, volume of test solution, and number and biomass of test species per chamber
(loading); dissolved oxygen concentration; food quality, quantity, and feeding regime; dilution water
quality; test duration; genetic make-up; and analyst experience. Because effluents and receiving waters
may contain complex mixtures of unknown toxic constituents, knowledge of the range  of toxic response
exhibited by representative  species of aquatic organisms is necessary for the protection of aquatic life in
receiving waters. The assessment of toxicity requires the use of several aquatic test species representing
different phylogenetic groups that display a wide range of sensitivity.

      In WET testing, precision usually is described as the test consistency or repeatability both in a
single laboratory (intralaboratory) and among multiple laboratories (interlaboratory) using the same WET
test procedure and water sample. Comparison of the toxicity test endpoint  determined using the same
method, test conditions, and test sample will allow  for the calculation of intralaboratory or interlaboratory
precision. WET tests must address the inherent variability of toxic response and natural variability of
within-species sensitivity exhibited by test organisms.  Replicate tests, specified physical and chemical
parameters, standardized test procedures, and test acceptability criteria are included in the EPA-approved
methods  to account for the intrinsic variability of WET tests.

                                                7                                   January 1999

-------
Approval of New Methods and ATPSfor Whole Effluent Toxicity
      Additional discussion of the sensitivity and precision of WET tests is included in the EPA WET
methods manuals and the TSD (USEPA, 1994a, 1994b, 1993a, and 199la).
1.6     Use of Resident Species

        Regulatory agencies may require the use of resident or indigenous species, under the assumption
that such tests are  needed to assess impact to local biota. Resident species are species that are present at
a specified site for some portion of its lifespan. Indigenous  species are species that are likely to occur at a
selected site for  some part of its life as a native species (ASTM, 1998). While the use of species taken
from the receiving water may have appeal, EPA considers  it unnecessary to conduct WET tests with
resident or indigenous species, whether the organisms are collected for direct use in WET tests or for
spawning  to obtain eggs or larvae for culture, because based on many years of development and use by
EPA, states, municipalities, academia, and the regulated community it has been demonstrated that the
Agency-approved  test species are appropriate for the NPDES program. The following factors may make
it impractical to  use resident species in toxicity tests (USEPA, 199la):

•       Sensitive organisms may not be present in the local receiving water because they may have
        acclimated to the ambient environment through prior exposure to toxic effluents, receiving waters,
        or other pollutants.

•       Handling of organisms during field collection and transport may cause excessive mortality or
        sublethal effects.

•       It may be difficult to collect sufficient numbers of feral  organisms  of the required life-stage and
        quality from the receiving water throughout the year.

•       Culturing organisms from broodstock collected in the field may be difficult and costly.

•       Test species collected directly from the receiving water may not be used immediately because of
        possible parasitic or bacterial disease, physical injury, or collection-induced stress, which may
        result in early mortality or excessive sensitivity to the test conditions.

•       Most states require collection permits, which may be difficult to obtain. Therefore, it is usually
        more cost-effective to culture them  in the lab or obtain them  from experienced private or state
        sources. Fish such as fathead minnows, sheepshead minnows, and silversides, and invertebrates
        that include daphnids and mysids, are readily reared in the laboratory or obtained from
        commercial sources.

•       Since it  is  mandatory that the identity of test organisms is known to the species level, it would be
        necessary to examine each organism caught in the wild to confirm its identity and/or age. Such
        identification may be impractical or, at the least, stressful to the organisms.

•       Unknown  reproductive states at the time of collection might produce aberrant results due to
        interactions between breeding condition and metabolism or toxicity of contaminants.
                                                                                    January 1999

-------
                                                Approval of New Methods and A TPsfor Whole Effluent Toxicity
       Historical quality assurance\quality control (QA/QC) records (control charts) and intralaboratory
       and interlaboratory performance data indicating the precision and reproducibility of test method
       may not be available for resident species.
•      For nationwide applications, the test species may not be widely available at a fair market price in
       the appropriate life-stage for testing purposes throughout the year or may require culturing or test
       conditions, laboratory equipment, or analyst expertise that cannot be duplicated in all qualified
       WET labs.

       EPA generally discourages the use of resident species toxicity testing unless it is required by a
state statute or some other legally binding factor, or supporting data has been developed by an EPA
Regional or state discharge permit program, permitee, or community member that demonstrates that a
unique endemic species would provide a more accurate reflection of effluent compliance and be more
protective of the local receiving water than  the species in Agency-approved methods (USEPA, 199la).

       In most cases, applicants seeking approval for use of a resident species should follow the method
validation and approval process  for new WET methods.  Further specific guidance on the selection and
use of resident species in aquatic toxicity tests is available in the EPA WET methods manuals (USEPA,
1994a, 1994b, 1993a), the TSD  (USEPA, 199la), and a  series of guidance documents (USEPA, 1973,
1990, 1993bandASTM,  1998).


2.0   APPLICATION REQUIREMENTS

       Every new method and ATP application shall be made in triplicate and shall include a completed
New Method and ATP Application Form for Whole Effluent Toxicity (provided in Appendix A) with
required attachments.

2.1    Submission Addresses and Approval Authority

       A summary of where to submit new methods and ATP applications and the approval authorities
for each tier level are provided in Table 2. An application for nationwide (N W) approval (Tier 2 or 3) of a
proposed method should be forwarded to the Director, Analytical Methods Staff, Engineering and
Analysis Division (4303), USEPA, 401  M Street, SW, Washington, DC 20460. An application for
limited use (LU) approval (Tier  1) of a new method or ATP by a Regional EPA laboratory shall be
forwarded directly to the appropriate EPA Regional Administrator. An application for limited use (LU)
approval (Tier 1) of a proposed method by a state, commercial laboratory, an individual discharger, or
permittee shall be forwarded directly to the Director of the state agency authorized to operate an EPA-
approved NPDES permit program under Section 402 of CWA. If the state does not operate its own
permit program, then the application by a state, commercial laboratory, individual discharger, or
permittee shall be forwarded directly to the appropriate EPA Regional Administrator. Applications to the
Regional Administrator may be submitted through the Regional ATP Coordinator; an address list for the
Regional ATP Coordinators is provided in Appendix B. The Regional Administrator may choose to
                                                                                January 1999

-------
Approval of New Methods and A TPS for Whole Effluent Toxicity
forward Tier 1 (LU) applications to the Director of the Analytical Methods Staff (AMS) for an approval
recommendation.
                                               10                                 January 1999

-------
                                                Approval of New Methods and ATPs for Whole Effluent Toxicity
         Table 2: Submission of Proposed WET Method Applications for Approval
TIER
Tierl
Tier 2
Tier 3
LEVEL OF
USE
Limited Use
Nationwide
Use
Nationwide
Use
APPLICANT
USEPA Regional laboratories
States, commercial laboratories,
individual dischargers, or
permitees in states that do not
operate an NPDES permit
program under Section 402 of
CWA
States, commercial laboratories,
individual dischargers, or
permitees in states that operate
an permit program under Section
402 of CWA
All applicants
All applicants
SUBMIT APPROVAL
APPLICATION TO AUTHORITY
EPA Regional
Administrator (Regional
ATP Coordinator)
EPA Regional
Administrator (Regional
ATP Coordinator)
Director of state Agency
issuing the NPDES permit
Director, Analytical
Methods Staff, EPA
Headquarters
Director, Analytical
Methods Staff, EPA
Headquarters
EPA Regional
Administrator
EPA Administrator
EPA Administrator
       Upon receipt of the application, the state agency or EPA will assign an identification number to
the application. The applicant should use the identification number in all future communications concerning
the application.

2.2    Application Information

       Information required on the new method or ATP application includes whether the proposed
method is a new method or ATP, the name and address of the applicant, the date of submission, the title
of the new method or ATP, the title of the EPA-approved method that is being modified in the ATP
(ATPs only), the level of use desired (i.e., limited use or nationwide use), the validation tier level, and
information about the applicant's NPDES permit if applicable (Tier 1 and 2 validation levels only). The
New Method and ATP Application Form for Whole Effluent Toxicity is attached as Appendix A.

       In addition, the following items must be submitted with the application: a brief summary and
rationale  for approval of the proposed method; the proposed method, prepared in standard EPA format; a
method comparison table that gives a side-by-side comparison of the modified method and the EPA-
approved method (ATPs only); the method validation study plan;  the method validation study report,
including supporting data; and, for nationwide applications that will undergo rulemaking, method
information to facilitate preparation of the Preamble and Docket during EPA rulemaking.
                                              11
January 1999

-------
Approval of New Methods and A TPSfor Whole Effluent Toxicity
       Because of the complex nature of assessing the performance of new test methods and ATPs
that determine method-defined analytes, it is highly recommended that applicants contact EPA for
preliminary guidance prior to performing the validation study and submitting the formal
application. All of the above-listed attachments do not need to be submitted with the initial application.
The applicant may request that EPA make an initial determination whether or not a modification is
allowed within the method-specified flexibility or whether a potential ATP or new method meets the
needs of the NPDES biomonitoring program. The minimum information required for EPA to begin
reviewing an application is the completed application form, the proposed method in standard EPA format,
the method comparison table, and the proposed validation study plan. From this information, EPA can
determine whether the applicant should proceed with the full validation.

       The elements for a complete  application for each tier level are presented in Table 3. The
appropriate approval authority must receive all required application information and attachments before
the application is considered complete.

      	Table 3: Application Requirements	
          Tier
          Tier 1
          Tier 2
          Tier 3
        Level of Use
Limited Use
                    Nationwide Use
      Application Requirements
Completed Application Form
Summary and Rationale for Approval
Method in EPA Format
Method Comparison Table (ATPs only)
Validation Study Plan
Validation Study Report
                              Completed Application Form
                              Summary and Rationale for Approval
                              Method in EPA Format
                              Method Comparison Table (ATPs only)
                              Validation Study Plan
                              Validation Study Report
                              Method Information for Preamble and Docket
2.3    Standard EPA Method Format

        In accordance with the standard EPA format advocated by EPA's Environmental Monitoring
Management Council (EMMC), methods must contain 17 specific topical sections in a designated order.
The 17 sections listed in Section 8.0 (Appendix C) of this document are mandatory for all methods.
Additional numbered sections, however, may be inserted starting with Section 11.0, Procedure, as
appropriate for a particular method.  For more detailed information on the format for proposed methods,
see EPA's Guidelines and Format document (USEPA, 1996b). If the organization developing the new
method or ATP is a voluntary consensus standards organization (e.g., Standard Methods, ASTM) or
government organization with a standardized format, that format may be used.
                                              12
                                                              January 1999

-------
                                               Approval of New Methods and ATPs for Whole Effluent Toxicity
2.4    Method Comparison Table

       As part of an ATP application, the applicant must perform an in-depth comparison of the
proposed ATP with the EPA-approved method that has been modified, and document the comparison in a
two-column method comparison table. The two-column method comparison table shall include the number
and title of each method, the latest revision date of the proposed ATP, and a detailed discussion of each
of the 17 topics (as required by the standard EPA method format described in Section 8.0 of this
document). Each topic should be discussed on a separate row in the method comparison table. The
applicant should highlight any differences between the proposed ATP and the approved method that has
been modified. This comparison is not required for new WET methods.

2.5    Validation Study Plan

       Prior to conducting all validation studies, the applicant must prepare a validation study plan. The
validation study plan should contain the elements listed below:

•      Background
•      Objectives
•      Study Management
•      Technical Approach
•      Data Reporting and Evaluation
•      Limitations

       These elements  are further described in Section 3.6.

2.6    Validation Study Report

       The applicant must conduct a validation study and provide a comprehensive validation study
report with the new method or ATP application. The validation study report must include the following
elements:

•      Background
•      Study Implementation
•      Data Reporting and Validation
•      Results
•      Data Analysis/Discussion
•      Conclusions
•      Appendix A - The Method
•      Appendix B - Validation Study Plan
•      Appendix C - Supporting Data (Raw Data and Example Calculations)

       These elements  are further described in Section 3.7.
                                             13                                 January 1999

-------
Approval of New Methods and A TPSfor Whole Effluent Toxicity
2.7     Documentation to Facilitate EPA Rulemaking

        For Tier 2 and 3 applications, new methods or ATPs are approved by the EPA Administrator
through rulemaking. In these cases, the applicant shall provide information that will aid EPA in preparing
the preamble for the proposed rule that will be published in the Federal Register and relevant supporting
documents used in developing the new method or ATP for EPA inclusion in the rule docket. Specifically,
the applicant shall submit information that:

•       Defines the purpose and intended use of the method.
•       States what the method is based upon, noting any relationship of the method to other existing
        analytical methods, and indicates whether the method is associated with a sampling method.
•       Identifies the matrix types for which the method has been found satisfactory.
•       Describes method limitations and indicates any means of recognizing cases where the method
        may not be  applicable.
•       Outlines the procedure  that is  followed to determine the toxicity of the effluent, receiving water,
        and reference toxicant samples tested. In this description, the basic steps involved in performing
        the test and data analysis must be identified, but the details that are a necessary part of the
        complete statement of procedure  should be omitted.
•       Describes the end-point statistics and gives example calculations.
•       Lists options to the method, if applicable.
•       Discusses test acceptability criteria development (new methods only).
•       Describes and discusses the validation study report,  including study design and objectives, study
        limitations, study management, technical approach, data reporting and validation, results, data
        analysis discussion, and conclusions.

        Previous method rules  can serve  as examples of the type of information and the appropriate level
of detail necessary. Examples of preambles for method rules include 49 FR 43234, October 26, 1984; 56
FR 5090, February 7, 1991; 60 FR 53988, October 18, 1995; and 61 FR 1730, January 23, 1996.

2.8     Proprietary  Information in Applications

        All information provided to the Federal government is subject to the requirements of the Freedom
of Information Act.  Therefore, any proprietary information submitted with the proposed WET method
application should be marked as confidential. EPA staff will handle such information according to the
regulations in subparts A and B of 40  CFR Part 2.

        In accordance with 40 CFR §2.203, a business that submits information to EPA may assert a
business confidentiality  claim covering the information by placing on (or attaching to) the information at
the time it is submitted  to EPA, a cover sheet, stamped or typed legend, or other suitable form of notice
employing language such as trade secret,proprietary, or company confidential. Allegedly confidential
portions of othenvise non-confidential documents should be clearly identified by the business, and may be
submitted separately to  facilitate identification and handling by EPA. If the business desires confidential
treatment only until a certain date or until the occurrence of a certain event, the notice should so state.

        If a claim of business confidentiality is not made at  the time of submission, EPA will make such
efforts as are administratively practicable to associate a late claim with copies of previously submitted
                                               14                                 January 1999

-------
                                                   Approval of New Methods and ATPs for Whole Effluent Toxicity
information in EPA files. However, EPA cannot assure that such efforts will be effective in light of the
possibility of prior disclosure or widespread prior dissemination of the information.
                                                 15                                   January 1999

-------
Approval of New Methods and A TPSfor Whole Effluent Toxicity
3.0    METHOD VALIDATION

        NOTE: This is a draft document, and the requirements for method validation have not been
finalized. Potential new method or ATP applicants should contact EPA during the design phase of
validation studies to ensure that the most current requirements are followed.

3.1     Introduction

        Method validation is the process that establishes the performance of a new method or
substantiates the performance of an ATP. All proposed new methods and ATPs must be validated in
single or multiple laboratory studies to demonstrate that they can achieve precision and sensitivity that
meets or exceeds that of approved methods. This is necessary to ensure that new methods and ATPs
are capable of yielding reliable data for compliance monitoring purposes, and to ensure that the
environmental protection provided by the WET program is consistent.  Alternate  test procedures will be
compared to the unaltered approved method, and new test methods will be compared to the suite of
approved methods.

        To demonstrate precision of the new method or ATP, tests must be conducted on multiple
replicates of real-world and reference toxicant samples.  For limited use approval, tests may be conducted
in a single laboratory, but for nationwide use approval, tests must be conducted in multiple laboratories.
Interlaboratory testing of new methods requires a more rigorous nine laboratory design than
interlaboratory testing of ATPs, which requires only three laboratories.  To demonstrate sensitivity of the
new method or ATP, side-by-side testing in a single laboratory must be conducted using the proposed new
method or ATP and an approved method.

        Proposed new WET methods and ATPs must be validated in a variety of water samples  that
include real-world matrices and reference toxicants. In relation to WET, a real-world matrix type  ("matrix
type") is defined as an effluent with common characteristics from a given industrial subcategory or
publicly-owned treatment work (POTW) or a field collected freshwater, estuarine, or marine receiving
water with common characteristics from a given receiving water source. Tests with effluents and
receiving waters are used to evaluate the acceptability of the proposed method using samples collected
directly from the environment. There is one effluent representative of each industrial subcategory and
POTW  facility. The individual industrial subcategories are defined in the regulations at 40 CFR parts 405 -
471 (USGPO, 1996). Examples of appropriate matrix types include the following: primary POTW
effluent, C-stage effluent from chlorine bleach mills, effluent from the Continuous Casting subcategory of
the Iron and Steel industrial category, Lake Superior water, or Chesapeake Bay water. Validation of
proposed methods require testing of one to nine matrix types depending on whether the applicant is
seeking limited use or nationwide use approval.

        Because the accuracy and sensitivity of test species to detect toxicity cannot be "calibrated"
before each WET test, the test must include standard reference  toxicants to ensure data integrity. These
reference toxicants are chemical compounds prepared in the laboratory that are used to check the
performance of the WET method under study. Reference toxicant tests are a part of the routine QA/QC
program used in WET testing to evaluate performance of laboratory personnel, equipment, and test
species. Reference toxicants, as opposed to effluents or receiving waters, are of a known chemical
composition and toxicity. Reference toxicants are used to assess the  sensitivity of the organisms being
used in  the test and the suitability of the test method for compliance monitoring. Salts, metals, and

                                               16                                 January 1999

-------
                                                  Approval of New Methods and ATPs for Whole Effluent Toxicity
organic compounds are usually used as reference toxicants in WET tests. Additionally, it is suggested that
reference toxicants are selected that display different modes of toxicity (e.g., neurotoxin, teratagen).
Validation of proposed methods require testing of at least three reference toxicants. A list of several
commonly used reference toxicants are provided in Appendix D.

        All validation study results with selected matrix types and reference toxicants must be submitted
along with all required documentation to the designated regulatory authority as a part of the formal new
method or ATP application. Additionally, the applicant must maintain the completed application and have
this documentation available for inspection by permitting authorities, laboratory certification authorities,
and regulatory agencies.

        Ideally, a proposed WET method should be substantiated through a classical interlaboratory
(multi-laboratory) method validation study that resembles those used historically by EPA, ASTM, AOAC-
International and other organizations for validating  chemical methods (ASTM, 1994, Youden, 1978, and
Wernimont, 1985). EPA recognizes, however, that a classical interlaboratory method validation study may
be prohibitively costly to  implement, especially for small laboratories and regulated entities. Therefore,
EPA has developed a three-tiered approach that is  applicable to the validation of WET methods. Further
discussion of the tiered-validation system and the validation requirements for new methods and ATPs at
each tier level are described in Sections 3.2 - 3.4 below.

3.2     Tiered Validation System For Proposed WET  Methods

        The tiered system classifies the intended use of a method and requires a method validation study
that reflects the level of use associated with each tier. The three tiers as they apply to WET methods are
summarized in Figure 1 and further discussed in Section 3.2.1- 3.2.3 below.

                              Figure 1: Tiered Validation System


           Tier 1 refers to new methods or ATPs that will be used by a single laboratory
           (limited use) for one or more matrix type(s). Tier 1 contains two levels of validation,
           depending on whether the individual laboratory will be applying the new method or
           ATP to a single  matrix type or to multiple matrix types.

           Tier 2 refers to new methods or ATPs that will be used by all laboratories
           (nationwide use) analyzing samples of one matrix type. Validation requirements are
           for a nine-laboratory validation study for new methods and  three-laboratory validation
           study for ATPs.

           Tier 3 refers to new methods or ATPs that will be used by all laboratories
           (nationwide use) in all matrix types. Validation requirements are for a nine-
           laboratory validation study for new methods and a three-laboratory validation study
           for ATPs.
                                                17                                  January 1999

-------
Approval of New Methods and A TPSfor Whole Effluent Toxicity
3.2.1   Tier 1 Validation Studies

        Tier 1 is expected to be used by commercial laboratories, dischargers, and state and municipal
laboratories repetitively testing samples of the same matrix type(s) from the same site(s) on a routine
basis. The primary intent of Tier 1 is to allow use of a new WET method or ATP by a single laboratory.
Tier 1 can be applied to a single matrix type or multiple matrix types. If a laboratory intends to apply the
method to more than one matrix type, the laboratory must validate the method on each matrix type, to a
limit of nine matrix types.

        For Tier 1 validation studies, all tests must be conducted in a single laboratory on one matrix type
and three reference toxicants. New methods and ATPs validated under Tier 1 may be approved for use
only at the laboratory at which the Tier 1 validation study was conducted. Applicants may test an effluent
or receiving water as the matrix type.-At least four complete WET tests (four replicates) must be
conducted with separate "aliquots" of each matrix type and reference toxicant included  in the study.  If a
method is validated by  a single laboratory using one to eight discrete matrix types, the validation is
applicable only to those matrix types tested. However, once a laboratory has validated the method on nine
matrix types, the validation is applicable to all other matrix types.

3.2.2   Tier 2 Validation Studies

        Tier 2 validation studies are expected to be used by dischargers and state  and municipal
laboratories repetitively testing samples from the same matrix type from multiple sites on a routine basis.
The intent of Tier 2 is to allow all regulated entities and laboratories to apply a new method or ATP to a
single matrix type for nationwide use. EPA believes that implementation of Tier 2 will encourage the
development and application of new techniques that apply to samples from a given industry , POTW
facility, or receiving water source.

        Tier 2 validation studies of new methods are performed in a minimum of nine laboratories and the
validation of ATPs are conducted in a minimum of three laboratories. Each laboratory must test the  same
matrix type and the same three reference toxicants. Applicants may test an  effluent or receiving water in
the Tier 2 study. At least two complete WET tests (two replicates) must be conducted with separate
aliquots of each matrix type included in the study, and at least four complete WET tests (four replicates)
must be conducted with each reference toxicant included  in the study. Following completion of Tier 2
validation, the method will be appropriate for the matrix type in which it was validated. In contrast to  Tier
1,  once a new method or ATP has been validated under Tier 2, the validation study results can be
transferred to other laboratories, and the other laboratories may freely use the method, provided that the
method is applied to analysis of samples of the matrix type(s) for which the  method has  been validated.
Additionally, the  other laboratories must meet all of the method's test acceptability criteria. If the new
method or ATP is to be applied to another matrix type, the proposed method must  be validated on that
specific matrix type.

3.2.3   Tier 3 Validation Studies

        Tier 3 studies are expected to be used by vendors, commercial  laboratories, dischargers, and state
and municipal laboratories testing a wide variety of matrix types from diverse sites. The primary intent of
Tier 3 is to allow nationwide use of a new method or alternate WET test procedure by all regulated

                                                18                                  January 1999

-------
                                                Approval of New Methods and ATPs for Whole Effluent Toxicity
entities and laboratories. For example, Tier 3 should allow commercial vendors to establish that new
methods or ATPs for WET produce results that are acceptable for nationwide compliance monitoring
purposes and should allow laboratory chains to apply new technologies or alternate techniques throughout
their chain of laboratories to a variety of matrix types.

       Tier 3 validation studies of new methods are performed in a minimum of nine laboratories using a
minimum of nine different matrix types.  Each laboratory shall test at least six of the nine matrix types,
such that all matrix types are evaluated at a minimum of six laboratories.  Tier 3 validation studies of
ATPs are performed in a minimum of three laboratories using a minimum of nine different matrix types.
For all Tier 3 studies, at least 7 of the nine matrix types must be effluents. Additionally, each laboratory
must test the same three reference toxicants. As with Tier 2, at least two complete WET tests (two
replicates) must be conducted with separate aliquots of each matrix type included in the study, and at least
four complete WET tests (four replicates) must be conducted with each reference toxicant included in the
study.

Note: Applicants may choose to employ a "referee laboratory" to conduct preliminary tests and to
collect, prepare, and distribute samples to participant laboratories.

3.3    Summary of Tier 1, 2, and 3 Validation  Requirements for WET Methods

       The requirements for method validation studies for new methods and ATPs are summarized in
Table 4 and 5, respectively. Further specific validation study requirements are provided in Section 3.4.
                                               19                                 January 1999

-------















(A
TJ
0
.n
+-i
i
a>
z
Vx
£
rements
'5
o
a>
a:
c
o
"ra

"ro

^^
0)
^2
H












'S JQ *~
° -|t--

*o

fl> 12

E ™

z
«-
— >- ° "re
.2 jg Q.-J

h~ C (Q Q)
zw

(M
W
re
u
'x
o
o
u
c
£
£
01
£


I/I
a

j—
X
re
S
2
W
I
re
01


0)
w
3
t»
a>
l_

"o
o


o
i-















11 fill
3 "S ° " S.
2CC OT
O o
11
E a.
3 a>
zoc
**~ (U
fell
^ £ o
EJ2x
3 0) O
ZKI-
"5 W j3
lli||s
2 w

o|
fl) ^
^ Qit
Ea.
3 a>
za:
„_
o
*- _L "o .25 to
Z









2










^0
-^


fS






^>


•*




Tj-






T3
O
tj
S
Z

2










VO
— '


(N






n


^




Tj-






0
"S
0
ex
ex
rs

"3
o
H




































X

(U O .^

s
2










^0
-^


fS






«


^




Tt






ID
O
J2
1>
S
CJ

2










^0
— H


(N






m


*




T^-






Method
T3
dj
0
ex
ex
S

"3
o
H




































-ii*-«


f— ^ S H

o










0
'—


OO






r,


(N




. ^
> t/J
•^ QJ
s .S
> «
""§ £
t- _j_j
ex ™
I i
monstrate
ie nine rea
•o
0 0
*^ 2
0 £
•5 «
OJ
S . rn"
S "S j™
"O "^3 i_
> § r?
and an apprc
etal, organic,
al is sought.
1 E o
g % S
c w n
| gf _
o <£ £
o*^ c
111"
-(i D * L(
C "£ t
i^ ^
»1£,
0 g 'C
V- O TO
a,* E
• — < 
-------

















2
T3
•-
o

* JD
E™

z


- °«-S
!| I'd
zw°-





U)
n
o
'x
o
1-
u
c
V
^
"S
ce




n
o
a
1—
x
13
5
T3
1
a
£






TJ
0)
U)
O
In
a)




—
0)
j

u
*"

















"S g~ W ^

"o J3 2 "o ^"^
H~ E «£2 /S o

za OT

"S 8
11
Eg.
ziS

o g »
fc. c C
O fl) (0
J2 " 0

3 0) O
Z ^ H
O 0) ^j
Z
o 2
1.1
Eo.
3 
J-" ^ •-• p.

H|SH




fN
"*




m





2



(N





-



^



(N

fN


_H





a.
H
"•








•^t











Tf



~





-



f->



fN

fN


_




-a
0
S
"S
o

o.
cx

""•



so
«f)

CQ
'S
H












































 J^
2 3
a. £

i f
1 1
o S
•a o
0 Z

-a "«
jz >-
"S u
1 1
S _c
QJ ^-i
cl £
.2-a^
U ^ I—
•g'S H g
o §>£ 1
l°- "

fll 'fcj M Pi
•S •• ™ X
roposed ATP an
different classes
ATP approval is
ample.
additional matri
S" 2 ^"S "1
•^ -^— (~; rt dj
•f ^*g*S'l
3 O oj o U
T3 j- PH a ^
| 1 1 S ^

S ~° 2 S1 u
*J "O Q ^ "S


£ .1 "3 * c
O "^ ^ OJ rt
5 !5 — "E.^
|!s|>
g 3 |g ^ "
o '| •» -5 3




•S g ". S ^ *^ ^ ^ cr

" — ^ "E. ""
^ 4^ Q 1U _C
en < u- &. f-

-------
Approval of New Methods and ATPSfor Whole Effluent Toxicity
3.4    Specific Validation Requirements for New Methods and Alternate Test
       Procedures

       The following requirements apply to the validation of new methods and ATPs for WET at all tier
levels. Where requirements differ between new methods and ATPs, the individual section is divided into
subsections. The information contained in sections that are not subdivided is applicable to the validation of
all proposed WET methods.

3.4.1  Distribution of Method and Validation Study Plan

       Prior to conducting the validation study, the organization responsible for developing or modifying a
method must detail the full method in standard EPA format in accordance with the Guidelines and Format
document (USEPA, 1996b). The documented method should be distributed along with the validation study
plan and any additional guidance to each laboratory participating in the validation study.

3.4.2 Side-by-Side  Tests

       Side-by-side testing is required for the validation of new methods and ATPs. Each side-by-side
test is referred to as a "test set". For ATPs, side-by-side tests must be conducted with the proposed
method and the EPA-approved method that is being modified. For new methods, side-by-side tests must
be conducted with the proposed method and at least one of the approved methods. This side-by-side
testing requirement is designed to establish the relative sensitivity of the new method or ATP compared to
approved methods. Approved methods conducted in the side-by-side testing must be conducted according
to the guidelines and procedures in the WET method manuals.  For ATPs, each side-by-side test must be
conducted with the same batch of test organisms, reference toxicant and/or matrix type, test sample
concentrations, number of replicate chambers per concentration, and using the test conditions and
procedures specified in the EPA-approved method or specified in the NPDES permits. This list of
standardized test parameters for side-by-side tests may be adapted for ATP applications that seek to
modify the test sample concentrations, replicate chambers, or test conditions listed in the approved
method.

3.4.3 Replicate Testing

       At least four  complete WET tests (replications or repeat tests) must be conducted with each
reference toxicant included in the study. For single laboratory validation studies (Tier 1), four complete
WET tests (replications) must also be conducted with aliquots of each real-world matrix sample included
in the study. For multiple laboratory validation studies (Tier 2 and 3), at least two complete WET tests
(replications) must be conducted with aliquots of each real-world matrix sample. Applicants may include
more  than the minimum number of replicate tests if they desire. The replicate tests must be conducted
with the same tests concentrations,  test conditions, and data analysis methods. These replications apply to
the entire test and are  independent of the "replicate test chambers" required in several approved WET
tests. Based on the complexity of a proposed new method or  the magnitude of the modification(s)
included in a proposed ATP, the required number of replicate tests may be amended on a case-by-case
basis.
                                              22                                 January 1999

-------
                                                  Approval of New Methods and ATPsfor Whole Effluent Toxicity
3.4.4   Matrix Types

        Validation of proposed methods requires testing of from one to nine matrix types. All effluent and
receiving water samples must be collected using the type of containers, preservation techniques, shipping
and handling, and holding times described in the EPA WET methods manuals and outlined in Table II, 40
CFR part 136. In multiple laboratory validation studies ( Tier 2 and 3), each real-world matrix sample
should be tested in each of the laboratories. However, in validation studies that include multiple matrix
types and nine or more laboratories, each laboratory may test six of the nine real-world matrix type
samples, such that each of the real-world matrix types is tested in at least six laboratories.

3.4.5   Reference Toxicants

        Validation of proposed methods require testing of at least three reference toxicants. Reference
toxicants must be included from each of the three different classes: metal, organic, and salt. Reference
toxicants also should be selected that display different "modes of toxicity" (e.g., neurotoxin, genotoxin,
teratogen, membrane disrupter, enzyme inhibitor, etc.). A list of common reference toxicants is included
as Appendix D.  In multiple laboratory validation studies (Tier 2 and 3), each laboratory should test each
of the same three reference toxicants. However, in validation studies that include nine or more
laboratories, each laboratory may test two of the three reference toxicants,  such that each of the three
reference toxicants is tested in at least six laboratories.

3.4.6   Selection and Use of Test Species

3.4.6.1 New Methods

        Applicants seeking nationwide approval (Tier 2 or 3) should  ensure that the new test species are
widely available at a fair market price in the appropriate life-stage in sufficient quantity and quality for
testing purposes throughout the year and do not require unique culturing or test conditions, laboratory
equipment, or analyst expertise that cannot be duplicated in all qualified WET labs. The following
parameters apply to the selection and use of test species in new methods.

•       The taxonomic identity of each test organism must be determined to the species level (or strain
        for bacteria) by appropriate keys and verified by an appropriate expert. A species profile should
        be provided that describes the taxonomy, habitat, feeding regime, and other information to
        characterize the new species.

•       If purchased from a commercial supplier, the source of new test species must be reported.

•       If cultured in the lab,  a protocol for culturing and handling a new test species must be developed
        and included with the validation study report.

•       The appropriate life stage of the proposed species must be available year round for  use in testing.
•       A new test organism must tolerate handling (or collection) without excessive disruption of its life
        processes, and should be amenable to culturing, maintenance,  and testing under controlled
        laboratory conditions. An exception to the  lab culturing requirement may be  considered for the
                                                23                                  January 1999

-------
Approval oj New Methods and A TPSfor Whole Effluent Toxicity
       breeding stock of certain species that cannot be maintained in the lab or a feral organism that has
       been determined to be the most sensitive.

•      The necessary federal or state collection permits, or both, must be acquired prior to collecting
       feral organisms. Rare or endangered species must not be used in WET tests without prior
       approval of appropriate regulatory agencies.

•      Feral organisms captured by electroshocking must not be used in toxicity testing.

•      Test species collected directly from the receiving water should be held for an appropriate time
       period to observe them for possible parasitic or bacterial disease, physical injury, or collection
       induced stress which may result in early mortality or excessive sensitivity to the test conditions.

•      All individual tests must use a new batch of test species taken from the same in-house culturing
       facility or outside supplier.

       Additional discussion relevant to new test species for WET tests  is provided in Sections 1.5 and
1.6.

3.4.6.2 Alternate Test Procedures

       Generally, all ATPs submitted for approval will employ approved test species. Proposed methods
that use subspecies, species that have similar phylogeny (evolutionary history), or species that occupy the
same feeding guild as the Agency-approved species, may be considered  for approval as an ATP.
Approval of closely related test organisms as ATPs will be evaluated by EPA on a case-by-case basis.
Each test set must use a new batch of test species taken from the same in-house culturing facility or
outside supplier.

3.4.7  Replicate Chambers Per Concentration

3.4.7.1 New Methods

       Tests must employ at least the minimum number of replicate chambers per concentration listed in
the new method. If replicate chambers are not applicable to a new test procedure or concept, it is
suggested that the applicant include additional test replication (repeat tests).

3.4.7.2 Alternate Test Procedures

       The side-by-side tests with the approved and alternate method must be conducted with at least
the minimum number of replicate chambers per concentration listed in the approved method, unless the
purpose for the ATP is to propose a change in the number of replicate chambers.

3.4.8  Acute Tests - Sample Concentration Series

       For  each acute test, a series of at least five effluent, receiving water, or reference toxicant sample
concentrations based on a dilution factor of 0.5 is suggested. Ideally, the selected dilution series should
                                                24                                 January 1999

-------
                                                 Approval of New Methods and A TPs for Whole Effluent Toxicity
provide partial mortalities at two or more concentrations, including at least one concentration resulting in
no mortality and at least one concentration resulting in 100% mortality.

3.4.9  Short-Term Chronic Tests - Sample Concentration Series

       For short-term chronic tests, a series of at least five effluent, receiving water, or reference
toxicant sample concentrations based on a dilution factor of 0.5 is suggested. Ideally, the dilution series
chosen should provide at least two concentrations with no statistically significant effect on survival or
sublethal endpoints compared to control, and at least two concentrations with a statistically significant
effect on survival or sublethal endpoints compared to control.

3.4.10  Preliminary Toxicity Range-Finding Tests

       If the appropriate effluent, receiving water, or reference toxicant sample concentration needed to
meet the  exposure/response requirements  set out in Section 3.4.8 and 3.4.9 is unknown, it may be
necessary for the laboratory to perform one or more preliminary range-finding tests. While non-toxic
samples may be used in the validation study to document false positive rates, samples selected for use in
the validation study should generally exhibit a measurable level of toxicity (so that precision measurements
can be made). For this reason also, preliminary range-finding tests may be necessary. If blind test
samples are employed, a referee laboratory may conduct the preliminary tests and distribute appropriate
samples to participant laboratories for use in the study. The procedures for performing a range-finding
test are outlined in the EPA WET methods manuals (USEPA  1994a, 1994b, 1993a).

3.4.11  Quality Assurance and Quality Control

3.4.11.1       New Methods

       All tests conducted using the approved methods must comply with the general QA/QC criteria
provided in the EPA WET methods manuals.  For new methods, QA/QC criteria that is at least as
rigorous as that for approved WET methods should be developed and detailed in Section 10 of the
required EPA formatted method description (see Section 2.3 and Appendix C of this document). All tests
conducted using the new method must comply with the QA/QC criteria developed for the method.

3.4.11.2       Alternate Test Procedures

       All tests conducted using the approved method and alternate test procedure must comply with the
general QA/QC criteria provided in the EPA WET methods manuals.

3.4.12  Data Collection and Recording

       All physical, chemical, and biological observations normally  required for the Agency-approved
methods  shall be recorded for proposed and approved methods tested in a validation study report as
described in Section 3.7.10. For new methods, alterations to the list of observations may be necessary to
include additional parameters important to a new WET technology. Observations must be placed on
appropriate bench sheets in the format provided in the EPA WET methods manuals (see sections on
physical,  chemical, and biological observations during the tests, and test data reporting requirements).

                                              25                                  January 1999

-------
Approval of New Methods and ATPSfor Whole Effluent Toxicity
All raw data entries and changes in original entries shall be dated and initialed. Changes to entries must be
accompanied by suitable, legible justification. The format and/or identification of the original data sheets
shall be such that the date of entry and identity of the observer for each observation is obvious. The
original data sheets (e.g., bench sheets, logbook pages) and other required documentation (e.g., sample
information, deviations from methods) shall be retained by the performing laboratory, and copies appended
to the final validation study report.
Note: All data from the method validation study must be submitted to the approval authority,
including tests that were incomplete or results that were not comparable to the EPA-approved
method(s).

3.4.13 Physical and Chemical Parameters and Test Acceptability Criteria

3.4.13.1       New Methods

       Data assembled in the validation study and previous studies should be used to develop and
substantiate optimum physical and chemical test conditions and appropriate test acceptability criteria for
the new test method.

3.4.13.2       Alternate Test Procedures

       The control data from all side-by-side tests must meet the physical and chemical parameters and
test acceptability criteria listed in the approved method.

3.4.14 Raw Data Analysis - Determination of Test Endpoints

       Test endpoints for Agency-approved acute and short-term chronic tests performed in validation
studies for ATPs shall  be determined using the flow charts, guidelines, and statistical methods specified in
EPA WET methods manuals. For new methods, a data analysis scheme and flowchart shall be developed
in a format comparable to schemes for Agency-approved methods. Computer software used in data
analysis must be identified by source, version, and date, and a machine-readable, executable copy
provided if the software is accessible to the public. Software specifically recommended and/or provided
by the Agency, shall be used where applicable.

3.4.15 Statistical Analysis of Endpoints - Determination of Sensitivity and Precision

       The sensitivity and precision of proposed WET methods in selected matrix types and reference
toxicants must be determined from the validation data. Method performance will be assessed from test
endpoints generated from analysis of four replicates of a minimum of one matrix type and three reference
toxicants.  Sensitivity will be described as the degree of response of the proposed method, exhibited by the
test endpoints, to each matrix type and reference toxicant under study. This will be compared to the
response of the approved method in side-by-side testing. For intralaboratory and interlaboratory precision
calculations, in cases where the test data are used in Probit Analysis or other point estimate techniques
(LC,, LC50 and IC25),  precision must be described by the mean, standard deviation, and CV of the
calculated endpoints from the replicate tests. When the results are reported in terms of the NOEC,
LOEC, or other endpoints derived from hypothesis testing, precision can only be described by listing the
NOEC-LOEC interval for each test. The specific method performance requirements for new method and
ATP applications are discussed below.

                                              26                                January 1999

-------
                                                  Approval of New Methods and ATPs for Whole Effluent Toxicity
3.4.15.1       New Methods

        Determination of sensitivity and intralaboratory precision of the new method is required for
validation studies at all tier levels. Assessment of interlaboratory precision of the results is required for
Tier 2 and 3 validation studies. The performance of new methods will be compared to the suite of EPA-
approved WET tests using appropriate statistical techniques. Precision and sensitivity data for the EPA-
approved methods is published in the EPA WET methods manuals and the TSD (USEPA,  1994a, 1994b,
1993a, 199 la).

3.4.15.2   •   Alternate Test Procedures

        Determination of sensitivity and intralaboratory precision of ATPs is required for validation
studies at all tier levels. Assessment of interlaboratory precision is required for Tier 2 and 3 validation
studies. The performance of ATPs will be compared to the unmodified method using appropriate
statistical techniques. In order to be considered for approval, the statistical analysis must demonstrate that
the sensitivity and precision of the ATP is equivalent to or greater than that furnished by the approved
method in the side-by-side tests.

3.5    Selection of Laboratories to Participate in the Validation Study

        It is essential that laboratories selected to participate in a validation study demonstrate  that they
are qualified to conduct the EPA-approved WET tests. Problems with WET tests are caused most often
by the misapplication of the tests, misinterpretation of data, quality of the WET testing laboratory, and lack
of training and experience of laboratory personnel. The participants at the Society of Environmental
Toxicology and Chemistry (SETAC) Whole Effluent Toxicity Workshop in 1995 concluded that the
largest source of variability in WET testing is the level of analyst experience and judgement, and test
species  condition and health. EPA suggests that applicants assess the qualifications of potential
laboratories  before selecting them to participate in a method validation study. The following list provides
some items that applicants may request to assess WET  laboratory experience, capability, and proficiency:

•        General information on the combination of facilities, equipment, staff, and laboratory capabilities.
•        Specific information on sample handling, temperature control, source of water, type of food and
        source of foods, test equipment used for conduct of each test method, source of organisms,
        quality control measures for each organism, and resumes of principal laboratory staff.
        Internal Standard Operating Procedures  (SOPs) for conducting WET tests and data analysis and
        preparing cultures, food, and dilution water that have been in use at the laboratory for  each
        method included in the study.
        Historical QA/QC data (cusum charts) with approved methods and standard reference toxicants
        and an explanation of the derivation of associated control limits.
•        Results from DMRQA studies.
•        Recommendations from  clients for whom they have conducted WET tests.

        Applicants may also choose to have potential laboratories perform WET test(s) with a  provided
"prequalification sample" to demonstrate proficiency with a specific WET method. Additional guidance
                                               27                                 January 1999

-------
Approval of New Methods and ATPS for Whole Effluent Toxicity
and standardized procedures for evaluating potential laboratories is provided in the document titled,
Manual for the Evaluation of Laboratories Performing Aquatic Toxicity  Tests (USEPA, 1991b). Any
problems associated with laboratory selection should be discussed with EPA prior to initiation of the
validation study.
                                               28                                  January 1999

-------
                                                 Approval of New Methods and ATPs for Whole Effluent Toxicity
3.6     Validation Study Plan

        Prior to conducting Tier 1, 2, or 3 validation studies, the organization responsible for conducting
the study must prepare a validation study plan. A detailed study plan must be provided to the participating
laboratories prior to their involvement. As mentioned in the application requirements section, applicants
should consult with, or submit a validation study plan to EPA prior to initiation of the validation study. The
version of the study plan used in the method validation study must be submitted to EPA as part of the
formal application for approval. The validation study plan should contain the elements described in
sections 3.6.1 through 3.6.6.

3.6.7   Background

        The Background section of the validation study plan must include the following items:

•       Identify the method as a new method or ATP.
•       Include a method summary.
•       If an ATP, cite the method number (given in 40 CFR parts 136, Table 1 A) for the approved
        method.
«       If an ATP, describe the reasons for and extent of the modification, the logic behind the technical
        approach to the modification, and the result of the modification.
•       If a new method, describe the rationale for developing the method and identify the matrix types to
        which the method is believed to be applicable.

3.6.2   Objectives

        The Objectives section of the validation study  plan should describe overall objectives and data
quality objectives of the  study.

3.6.3   Study Management

        The Study  Management section of the validation study plan should include the following
information:

•       Identify the organization responsible for managing the study.
•       Identify laboratories, facilities, and other organizations that will participate in the study.
•       Delineate the study schedule.

3.6.4   Technical Approach

        The Technical Approach section of the validation study plan should address the following:

•       Indicate at  which Tier level the study will be performed.
•       Describe the  approach that will be followed by each organization involved in the study.
•       Describe how sample matrices (effluents, receiving water, and reference toxicants) and
        laboratories will be selected.
•       Explain how  samples will be collected, prepared, and distributed.


                                               29                                  January 1999

-------
Approval of New Methods and A TPS for Whole Effluent Toxicity
•       Specify the numbers and types of analyses to be performed by the participating laboratories.
•       Describe how analyses are to be performed.
•       Describe the type and timing of monitoring and observations required.

3.6.5   Data Reporting and Evaluation

        This section of the validation study plan should explain the procedures that will be followed for
reporting and validating study data and should address the statistical analysis of study results.

3.6.6   Limitations

        The Limitations section of the validation study plan should explain any limiting factors related to
the scope of the  study.

3.7    Validation Study Report

        Laboratories or other organizations responsible for developing a proposed WET method at Tier 1,
2, or 3 must document the results of the validation study in a formal validation study report that is
organized and contains the elements described in this section. The information and supporting data
required in the validation study report must be sufficient to enable EPA to evaluate the performance of
the new method  or support a claim of equivalent performance for an ATP.

        Like the validation study plan, the validation study report contains background information and
describes the study design. Additionally, the validation study report details the process and results  of the
study, provides an analysis and discussion of the results, and presents study conclusions. The study plan
must be appended to and referenced in the validation study report. The validation study report must
identify and discuss any deviations from the study plan that were made when implementing the study. The
validation study report must contain the elements described in sections 3.7.1 through 3.7.9.

3.7.1   Background

        The Background section of the validation study report must describe the new method or ATP that
was validated and must identify the organization responsible for developing the method. This background
section must do the following:

•       Identify  the method as a new method or ATP.
•       State  if for nationwide or limited use.
•       Include a method summary.
•       If an ATP, cite the method number for the approved method at 40 CFR part 136, Table 1A.
•       If an ATP, describe the reasons for and extent of the modification, the logic behind the technical
        approach to the modification, and the result of the  modification.
•       If a new method, describe the rationale for developing the method.
•       Identify  the matrices, matrix types, and/or media to which the method is believed to be applicable.
•       State  the purpose of the study.
                                               30                                  January 1999

-------
                                                  Approval of New Methods and A IPs for Whole Effluent Toxicity
3.7.2   Study Design and Objectives

        The Study Design and Objectives section of the study report must describe the study design, and
identify overall objectives and data quality objectives of the study. Any study limitations must be identified.

3.7.3   Study Implementation

        The Study Implementation section of the validation study report must describe the methodology
and approach undertaken in the study. This section must do the following:

•       Identify the organization that was responsible for managing the study.
•       Identify the laboratories, facilities, and other organizations that participated in the study;
        describe how laboratories were selected (prequalification criteria);  indicate whether a referee
        laboratory was employed; and explain the role of each organization involved in the study.
•       Indicate the tier level at which the study was performed.
•       Clearly describe all samples prepared for the study (e.g., type of samples, number of samples of
        each type, concentration of reference toxicants in samples).
•       Describe the rationale for selection of matrix types and reference toxicants, including a statement
        of compliance with tier requirements for matrix type selection. Indicate the source of effluent
        and/or receiving water samples and reference toxicant (chemical supplier).
•       Describe how effluent and/or receiving water samples were collected in the field.
•       Describe sample handling and storage.
•       Provide background information on each matrix type (if available) and reference toxicant (e.g,
        chemical class, % active ingredients, toxic mode of action), and describe how each was prepared
        (e.g, compound in which toxicant is dissolved) and distributed (e.g.,  sample volumes shipped,
        sample containers, blind samples).
•       Describe any preliminary testing conducted prior to the validation study (e.g., physical and
        chemical, preliminary range-finding toxicity tests).
•       Describe the role and specific tasks performed by the referee laboratory (if applicable).
        Provide the source, strain (if appropriate), and species profile of the test species.
        Indicate the dilution water(s) that was used in the study.
•       Specify the numbers and types of analyses performed by the laboratories (i.e, test conditions, test
        procedures, statistical analyses).
•       Identify any problems encountered with samples, test species, equipment, etc. and their
        subsequent resolution.
•       Identify any approved deviations from the study plan and their impact on study performance
        and/or results.

3.7.4   Data Reporting and Validation

        This section of the validation study report must describe the procedures that were used to report
and validate study data.
                                                31                                  January 1999

-------
Approval of New Methods and ATPSfor Whole Effluent Toxicity
3.7.5   Results

        This section of the validation study report presents the study results. Raw data and example
calculations are required as part of the results and shall be included in an appendix to the validation study
report (see section 3.7.10). For ATPs, this section must verify that the test acceptability criteria for the
approved method were met for the purposes of assessing equivalency with the EPA-approved method.
For new methods, the test acceptability  criteria developed from the validation study should be described.
A summary table shall be provided that lists the test method, the laboratory number, the sample number
and type, individual test results in chronological order, including test endpoints and confidence intervals
(where appropriate).

3.7.6   Data Analysis/Calculation

        This section of the validation study report must provide a statistical analysis and discussion of the
study results.  Precision and sensitivity data shall be calculated and summarized in tabular form  that
includes, the mean, standard deviation,  and percent coefficient of variation (CV) for endpoints that are
point estimates (LC50 and IC25), or ranges for endpoints  determined by hypothesis testing (NOEC,
LOEC). For ATPs, the discussion must address any discrepancies between the results and test
acceptability criteria of the EPA-approved method.

3.7.7   Conclusions

        The Conclusions section of the validation study report must describe the conclusions drawn from
the  study based on the data analysis discussion. The Conclusions section must contain a statement(s)
regarding achievement of the study objective(s).

3.7.8   Appendix A - The Method

        For new methods, the method,  prepared in standard EPA format, must be appended to  the
validation study report (USEPA, 1996b). For ATPs, the modified portion of the EPA-approved  method,
prepared in standard EPA format, must be appended to the study report.

3.7.9   Appendix B - Validation Study Plan

        The validation study plan must  be appended to the validation study report.

3.7.10 Appendix C - Supporting  Data

        The validation study report must be accompanied by raw data and example calculations that
support the results presented in the report. The validation study report must include all raw data so that an
independent reviewer familiar with WET testing may verify each analytical determination and calculation
performed by the laboratory. The full names, titles, addresses, and telephone numbers of the analysts who
performed the analyses, the laboratory contact (lab manager) responsible for the study, and the  quality
assurance officer who verified the analyses must be provided.
                                               32                                 January 1999

-------
                                                 Approval of New Methods and ATPs for Whole Effluent Toxicity
3.7.10.1 Raw Data

        The applicant shall provide copies of the original data sheets, bench sheets, or log book pages of
sufficient quality that all data entries (and changes, if any) are clearly legible. The raw data may include
any of the specific information listed below. Some of the items listed below may have been discussed in
the study implementation section of the study report.

        (1) Sample Information
           •   Sample numbers or other identifiers applied to individual samples
           •   Dates of sample preparation and/or receipt in the laboratory
               Sample temperature when received at laboratory
           •   Physical and chemical data of sample contents (as required in appropriate method)
           •   Dilution water
               -  Source and time frame water is used or how maintained
               -  Collection or preparation date(s), where applicable
               -  Pretreatment information
               -  Physical and chemical characteristics (pH, hardness, conductivity, salinity, etc.)
           •   Sample storage information
           •   Problems with samples and a description of subsequent resolution
        (2) Test Procedure and Conditions
           •   Toxicity test methods used (title, number, source)
           •   Test duration
               Endpoint(s) to be determined
           •   Approved deviations/modifications from method(s), if any, and reason(s)
               Date and time test(s) started, date and time samples were prepared and solutions
               transferred for renewals.
           •   Date and time test(s) terminated
           •   Type and volume of test chambers
           •   Volume of solution used per chamber
           •   Number of organisms per test chamber
               Number of replicate test chambers per treatment
               Feeding frequency and amount and type of food (be specific with sources, concentrations
               of foods, and preparation dates)
           •   Acclimation of test organisms (temperature mean and range  and, where applicable,
               salinity mean and range)
               Test temperature (mean and range)
           •   Test salinity, where applicable (mean and range)
           •   Other physical/chemical analyses such as pH, alkalinity, and  hardness, and dissolved
               oxygen, if applicable
               Specify if aeration was needed
           •   Specify if organisms were dried immediately for weighing or preserved prior to drying
               Specify how food was prepared and sources of food
           •   Describe how routine chemistries on new solutions  were made (in actual test chamber or
               in beakers after dispensing)
           •   Describe how randomization was conducted
                                               33                                 January 1999

-------
Approval of New Methods and ATPS for Whole Effluent Toxicity
       (3) Test Organisms
               Scientific name of test species, verification of species documented
           •   Taxonomic key used for species identification
           •   Age (life stage) of test species, be specific for all species; Age at time of test initiation
           •   Mean length and weight (where applicable)
               Source and QA/QC test conditions
           •   Holding conditions
           •   Diseases and treatment (where applicable)
               For new test species, notation that a voucher specimen was preserved and archived
       (4) Results
           •   Raw data from any preliminary tests (if applicable)
               Table of physical and chemical data taken during study
               Raw toxicity data in tabular form, including daily records of affected organisms in each
               replicate at each concentration (including controls) and plots of toxicity data or
               concentration vs. biological response
               Description of data analysis/statistical methods used to calculate endpoints and method
               performance data summarized in the results section of the validation study report

3.7.10.2   Electronic Data Reporting

       Applicants may also choose to submit data in  electronic format (Excel spreadsheet, or equivalent)
that will allow EPA to create a database of study results.  This database will facilitate automated review
and statistical analysis of study results. The information included in electronic format may include:
laboratory, analyst, method, sample type, sample number, date and time of analysis, test concentration,
replicate number, raw toxicity data (e.g., survival counts, dry weight), and calculated toxicity endpoints.
The applicant should  discuss an appropriate electronic  format with EPA prior to data submission.

3.7.10.3   Example Calculations

       The validation study report must provide example statistical calculations that will  allow the data
reviewer to determine how the  laboratory used the raw data to arrive at the test acceptability criteria
(new methods only), test endpoints, and method performance data.
4.0    EPA REVIEW AND APPROVAL

4.1     EPA Review of New Method and ATP Applications

        All requests for approval of proposed WET test methods will undergo review and approval by
EPA on an individual basis. The ultimate approval authority for new methods and ATPs is provided in
Table 2. New methods and ATPs for limited use (Tier 1) will be approved through an EPA "letter of
approval". Proposed methods for nationwide use (Tier 2 and 3) will be approved through rulemaking.
Ideally, proposed WET test methodologies prepared under this protocol should demonstrate one or more
of the following when compared to the existing EPA-approved WET methods:

•       Advances in test organism culturing, toxicity test procedures, and test concepts


                                              34                                 January 1999

-------
                                                 Approval of New Methods and A TPs for Whole Effluent Toxicity
•       Improved data collection and analysis techniques
•       Reduced test complexity
•       Reduced time for test completion
•       Reduced analytical costs
•       Enhanced test sensitivity and/or precision
•       Heightened level of protection to aquatic life in receiving water
•       Improved ecological relevance of test conditions and/or test endpoints

        The Agency believes that applications that meet the submission and validation requirements
outlined in this protocol, demonstrate any of the above attributes, and meet general standards of
performance and utility, will enhance the value of the Agency-approved methods for use in the NPDES
compliance monitoring program.

        EPA's Analytical Methods Staff (AMS) at EPA Headquarters will review all nationwide use
new methods and ATPs and will review limited use applications if requested by a EPA Regional office or
state agency. AMS may be assisted in its technical review by contractor personnel and internal EPA and
external expert reviewers. When a formal proposed method application is received, AMS will first check
the documentation for completeness. If the documentation is incomplete, AMS will contact the applicant
and request missing documentation before proceeding with its review.

        At a minimum, an application must include  a completed New Method and ATP Application
Form for Whole Effluent  Toxicity, the proposed test procedure in EPA standard format, the method
comparison  table, and the proposed validation study plan before AMS will review the package. If these
elements are present, AMS will assess the application to determine  whether or not an ATP is  allowed
within the method-specified flexibility and whether a potential ATP or new method meets the needs of the
NPDES biomonitoring program. AMS will notify the applicant if full validation should be conducted. If all
elements of the application are present, including the validation study report and supporting data, AMS will
begin an internal review of the new method or ATP for scientific merit, consistency, and appropriateness.
The internal EPA review may involve multiple programs and workgroups.

        Should any problems or questions arise  during the review, EPA or its technical support contractor
will communicate with the applicant to resolve outstanding issues.  Depending on the circumstances, EPA
may return the application to the applicant for revision. Internal review of proposed methods will involve
the three steps briefly described below.

        The first step of EPA's technical review will evaluate the clarity and completeness of the
description of the proposed method and the method comparison table, and assess its applicability for
approval at 40 CFR part 136.3, Table IA. In general, the applicability of a proposed WET test will
depend on the ease with which the test can be performed  on a routine basis, the consistency and
availability of test organisms, and  whether it meets the needs of the NPDES program. Proposed methods
submitted for Tier 2 or 3 approval will be evaluated to confirm that the test species and/or test material
are widely available at a fair market price in the appropriate life-stage throughout the year in sufficient
quantity and quality for testing purposes and they do not require culturing conditions, test  conditions,
laboratory equipment, or analyst expertise that cannot be duplicated in all qualified WET  labs
nationwide. If the proposed method is not applicable to §136.3 and/or the method descriptions are not
                                               35                                  January 1999

-------
Approval of New Methods and ATPSfor Whole Effluent Toxicity
acceptable, EPA will recommend rejection of the application. If this information is acceptable, the
evaluation will proceed.

        In the second step, the performance of the new method or ATP will be evaluated. The
performance (sensitivity and precision) and utility of new methods will be compared to the suite of EPA-
approved WET tests and considered for inclusion at 40 CFR part 136 on a case-by-case basis. For an
ATP, the review will begin with an assessment of the performance of the test results generated by the
EPA-approved method. If the data determined with the approved method are sufficient, the sensitivity,
precision, compliance with physical and chemical parameters and test acceptability criteria of the results
from the side-by-side tests with the ATP and EPA-approved method will be compared. In most cases,
data comparisons will be conducted using appropriate statistical techniques described in ASTM Standards
on Precision and Bias for Various Applications (ASTM, 1997). If method performance is acceptable,
the review will continue.

        As the third and final step, EPA will perform a detailed audit of the proposed method test data
and will verify calculations of test endpoints. The endpoints reported for the tests in the precision and
sensitivity validation studies and the descriptive statistics, such as the mean,  standard deviation, and
percent coefficient of variation of endpoints, will be  substantiated.

        As required following internal review, EPA may solicit additional evaluation of the proposed new
method  or ATP application from external expert reviewers.

4.2     Approval Recommendation

        After the completeness check and technical review, the AMS Director will prepare EPA's
recommendation for approval or rejection of the application. For ATPs, EPA will complete its review and
notify the applicant of its approval recommendation within 90 days of receiving a complete application.
For new methods, EPA will complete the review and notify the applicant within 120 days of receipt of a
complete application. For limited use applications (Tier  1), AMS will notify the applicant of EPA's
recommendation, and forward the recommendation  to the appropriate EPA  Regional or state approval
authority (see Table 2) for action. The Regional or state approval authority will issue the formal approval
for use of the proposed WET method. For nationwide use applications (Tiers 2 or 3), AMS will notify the
applicant of EPA's recommendation, and if the proposed method is recommended for approval, will
initiate the rulemaking process through which the new method or ATP is formally approved by the EPA
Administrator.

4.3     Rulemaking Process

        Using the method information and supporting documents provided with the new method or ATP,
EPA will draft the proposed rule to approve the proposed method, prepare the proposed rule docket, pass
the draft rule through internal review at EPA, and submit it to the Office of the Federal Register (OFR)
for publication. Preparation, approval, and publication of a proposed rule generally requires a
minimum of four months, and may take longer depending on the nature of the method. When
published, the proposed rule requests public comment and allows a specified comment period, generally 30
to 60 days.  At the end of the comment period, EPA will forward any significant comments to the method
applicant for technical assistance to EPA in drafting responses to comments. All comments that have
                                              36                                January 1999

-------
                                                Approval of New Methods and ATPs for Whole Effluent Toxicity
scientific or legal merit, or raise substantive issues with the proposed rule, must be answered to complete
the rulemaking process.

        EPA will review the comment responses provided by the applicant and complete the response-to-
comments document for the final rule. EPA will then prepare and submit the final rule to the OFR for
publication. The final rule will state the date that the rule becomes effective, typically 30 days after rule
publication. As of this effective date, the method is approved by EPA and will be included in the 40 CFR
§136.3, Table IA in the next CFR update. It generally requires a minimum of eight months after the
proposed rule is published to receive and respond to comments, prepare and process the final rule
through internal EPA review, and publish the final rule in the Federal Register.

        If  circumstances merit, EPA may issue a letter of approval to authorize nationwide use of a new
method or ATP during the rulemaking period.
                                              37                                 January 1999

-------
Approval of New Methods andATPSfor Whole Effluent Toxicity
5.0   REFERENCES

ASTM, 1994. Standard Practice for Determination of Precision and Bias of Applicable Methods of
    Committee D-19 on Water. Designation D-2777-86 (Reapproved 1994). Annual Book of ASTM
    Standards. Vol. 11.04.

ASTM, 1997. ASTM Standards on Precision and Bias for Various Applications. Fifth Edition.
American Society of Testing and Materials. West Conshohocken, PA.

ASTM, 1998. Standard Guide for Selection of Resident Species as Test Organisms for Aquatic and
    Sediment Toxicity Tests. Designation E-1850-97. Annual Book of ASTM Standards,. Vol. 11.04.

Federal Water Pollution Control Act, amended by the Clean Water Act,  33 U.S.C.A. §§ 1251-1387.

USEPA, 1973. Biological Field and Laboratory Methods for Measuring the Quality of Surface
Waters               and Effluents. U.S. Environmental Protection Agency. Methods Development
                     and Quality Assurance Laboratory, Cincinnati, OH. EPA-600-4-73-001.

USEPA, 1990. Macroinvertebrate Field and Laboratory Methods for Evaluating the Biological
Integrity             of Surface Waters. U.S. Environmental Protection Agency. Environmental
                     Monitoring Systems Laboratory, Cincinnati, OH. EPA-600-4-90-030.

USEPA. 1991a. Technical Support Document For Water Quality-Based Toxics Control. Office of
Water,               U. S. Environmental Protection Agency, Washington, DC. EPA-505-2-90-001.

USEPA, 1991b. Manual for the Evaluation of Laboratories Performing Aquatic Toxicity Tests. U.S.
    Environmental Protection Agency, Washington, DC. EPA-600-4-90-031.

USEPA. 1993a. Methods for Measuring the Acute Toxicity of Effluents and Receiving Waters to
    Freshwater and Marine Organisms. Fourth edition. Environmental Monitoring Systems Laboratory,
    U. S. Environmental Protection Agency, Cincinnati, Ohio. EPA-600-4-90-027F.

USEPA, 1993b. Field and Laboratory Methods for Evaluating the Biological Integrity of Surface
    Waters. U.S. Environmental Protection Agency. Environmental Monitoring Systems Laboratory,
    Cincinnati,  OH. EPA-600-R-92-111.

USEPA. 1994a. Short-term Methods for Estimating the Chronic Toxicity of Effluents and Receiving
    Waters to Freshwater Organisms. Third edition. Environmental Monitoring Systems Laboratory, U.
    S. Environmental Protection Agency, Cincinnati, Ohio. EPA-600-4-91-002.

USEPA. 1994b. Short-term Methods for Estimating the Chronic Toxicity of Effluents and Receiving
    Waters to Marine and Estuarine Organisms. Second Edition. Environmental Monitoring Systems
    Laboratory, U. S. Environmental Protection Agency, Cincinnati, Ohio. EPA-600-4-91-003.

USEPA. 1996a. Guide to Method Flexibility and Approval of EPA Water Methods. U.S.
Environmental  Protection Agency. Office of Water, Engineering and Analysis Division.  Washington,
              DC. EPA-821-D-96-006.

                                            38                                January 1999

-------
                                               Approval of New Methods and A TPs for Whole Effluent Toxicity
USEPA. 1996b. Guidelines and Format for Methods to Be Proposed at 40 CFR Part 136 or Part
141.   U.S. Environmental Protection Agency. Office of Water, Engineering and Analysis Division.
       Washington, DC. EPA-821-B-96-003.

USGPO. 1996. Code of Federal Regulations. Guidelines for Establishing Test Procedures for the
Analysis    of Pollutants. Vol. 40. U.S. Government Printing Office, Washington, DC.

Wernimont, G.T., 1985. Use of Statistics to Develop and Evaluate Analytical Methods. AOAC
       International.

Youden, WJ. and E.H. Steiner,  1975. Statistical Manual of the AOAC. AOAC International.
                                             39                                January 1999

-------
Approval of New Methods and A TPSfor Whole Effluent Toxicity
6.0    APPENDIX A - APPLICATION FORM
                                 EPA Office of Water
                       New Method and ATP Application Form
                             For Whole Effluent Toxicity
    New
ATP:
   Applicant Name and Address:
      Date Application Submitted:
   EPA Use Only
ATP Case No.
    New Method or Alternate Test
                   Procedure:
              (Method# & Title)
       EPA-Approved Method for
      Equivalency Demonstration:
                   (ATPs only)
                  Level of Use:
                   (LUorNW)
                 Validation Tier:
                     (1,2 or 3)
 FOR TIER 1 AND 2 APPLICATIONS ONLY:
 ID number of existing or pending permit:
 Issuing agency:
 Type of permit:
 Discharge serial number:
 ATTACHMENTS:
 |_J  Summary and Rationale

 rj  Method in Standard EPA Format

 Q  Method Comparison Table

 Q  Validation Study Plan

 rj  Validation Study Report

 |~|  Documentation to Facilitate EPA Rulemaking (Tier 2 and 3 only)

 r~|  Other	
                      Submit Application and Attachments in Triplicate
                                           40
                                      January 1999

-------
                                            Approval of New Methods and ATP's for Whole Effluent Toxicity
7.0    APPENDIX B - REGIONAL ATP CONTACTS
Region 1
Arthur Clark
USEPA Region 1
EQA
60 Westview Street
Lexington, MA 02173

Region 2
Linda M.  Mauel
USEPA Region 2
Division of Science and Monitoring
2890 Woodbridge Avenue (MS-220)
Building 10
Edison, NJ 08837-3679

Region 3
Charles Jones
USEPA Region 3
Environmental Assessment and Protection
Division
1650 Arch Street, 3ES-10
Philadelphia, PA 19103-2029

Region 4
Wayne Turnbull
USEPA Region 4
Science & Ecosystems Support Division
980 College Station Road
Athens, GA 30605-2720

Region 5
Kenneth Gunter
USEPA Region 5
77 W. Jackson Blvd.,WT-15J
Chicago, IL 60604

Region 6
Charles Ritchey
USEPA Region 6
1445 Ross Avenue (6MD-HX)
Dallas, TX 75202-2733
Region 7
Doug Brune
USEPA Region 7
726 Minnesota Avenue, ENSV/QA
Kansas City, KS 66101

Region 8
Rick Edmonds
Regional Quality Assurance Officer
USEPA Region 8
999 18th Street - Suite 500 (8TMS-L)
Denver, CO 80202-2466

Region 9
Roseanne Sakamoto
USEPA Region 9
75 Hawthorne Street, PMD-3
San Francisco, CA 94105

Region 10
Bruce Woods
USEPA Region 10
200 Sixth Avenue, OEA-095
Seattle, WA 98101
                                          41
                            January 1999

-------
Approval of New Methods and ATPSfor Whole Effluent Toxicity
8.0   APPENDIX C - STANDARD EPA EMMC FORMAT FOR WET METHODS

1.     Scope and Application
           Describe the proposed use of the method in the NPDES Program, and its limitations.

2.     Summary of Method
           Describe the essential elements of the test: applicable water matrices, test species, test
           duration, brief description of test procedure, and test endpoints.

3.     Definitions
           Include only specialized terms.

4.     Interferences
           Include known or potential interferences.

5.     Safety
           Refer to recognized safe laboratory practices, such as the use of hoods, goggles, and/or
           protective clothing, and appropriate material safety data sheets. Emphasize special
           procedures.

6.     Equipment and Supplies
           In addition to apparatus and equipment include any applicable source documents.

7.     Reagents and Standards
           Describe reagent formulations (e.g., dilution waters) and the shelf life of packaged materials.

8.     Test Organism Culturing/Maintenance Procedures
           If the proposed test species is not currently described in Agency-approved methods, provide
           detailed descriptions of the  systematics, distribution, ecology, and life history of the test
           species, and information on the proposed commercial source(s) of test species or detailed
           methods for their culture and/or laboratory maintenance.

9.     Effluent and Receiving Water Collection, Preservation, Shipment, and Storage
           Follow the guidance in Table II, 40 CFR part 136, unless modifications in sampling and
           sample handling and holding procedures are an essential part of the new method or ATP.
           Provide full details  on procedures used.

10.   Quality Control.
           Describe the proposed formal laboratory quality control program; initial and periodic
           demonstration of performance using common reference toxicants, and maintenance of
           records, QC charts, etc. Include a summary of test conditions.

11.   Calibration and Standardization
                                              42                                 January 1999

-------
                                                  Approval of New Methods and A TPs for Whole Effluent Toxicity
12.    Toxicity Test Procedure
           Include each procedural step and test condition. Provide a summary table of test conditions
           similar to those in existing Agency WET methods manuals, including test acceptability
           criteria.

13.    Acceptability of Test Results
           Include test acceptability criteria.

14.    Data Analysis
           Describe the raw data to be collected, the data analysis procedures, and statistical methods
           employed, including tables for recording raw data and calculated test endpoints, Provide data
           analysis and statistical diagrams and flowcharts.

15.    Method Performance
           Indicate the intralaboratory and interlaboratory test precision using appropriate reference
           toxicants and applicable matrix types.

16.    Pollution Prevention

17.    Waste Management

18.    References

19.    Tables, Diagrams, Flowcharts, and Validation Data
                                                43                                   January 1999

-------
Approval of New Methods andATPSfor Whole Effluent Toxicity
9.0  APPENDIX D - LIST OF STANDARD REFERENCE TOXICANTS

Metals:

Cadmium (Cd)
Cadmium chloride (CdCl2)
Copper (Cu)
Copper sulfate (CuSO4)
Hexavalent chromium (Cr6*)
Potassium dichromate (K2Cr2O7)
Zinc sulfate (ZnSO4)

Salts:

Potassium chloride (KC1)
Sodium chloride (NaCl)

Organics:

Phenol
Sodium dodecyl sulfate (SDS)
Sodium pentachlorophenate (NaPCP)
Sodium pentachlorophenol
                                        44                             January 1999

-------