In-Process
            Modifications and
                 Pretreatment
                       Upgrading Meatpacking

                     Facilities to Reduce Pollution
EPA Technology Transfer Seminar Publication

-------
     IN-PLANT MODIFICATIONS AND PRETREATMENT

                          Upgrading Meat Packing Facilities
                                      to Reduce Pollution
ENVIRONMENTAL PROTECTION AGENCY • Technology Transfer
                        October 1973

-------
                ACKNOWLEDGMENTS
     This seminar publication contains materials prepared for the
U.S. Environmental Protection Agency Technology Transfer Program
and presented at industrial pollution-control seminars for the meat
packing industry.

     The basic publication was prepared by A. J. Steffen, Consulting
Environmental Engineer, West Lafayette, Ind., with the assistance of
Dan Lindenmeyer, FMC Corporation, Chicago, 111.; M. E. Ginaven,
Bauer Bros. Company (subsidiary of Combustion Engineering, Inc.),
Springfield, Ohio; Robert Johnson, FMC Corporation, Atlanta, Ga.;
Charles Grimes, Rex Nord, Inc., Waukesha, Wis.; and W. H.  Miedaner,
Globe Engineering, Chicago, 111.
                            NOTICE

     The mention of trade names of commercial products in this publication is
for illustration purposes, and does not constitute endorsement or recommenda-
tion for use by the U.S. Environmental Protection Agency.

-------
                         PREFACE

     This presentation is particularly oriented toward owners, managers,
superintendents, and engineering and operating staffs of meat packing
facilities. No attempt is made to include meat processing at locations
apart from killing plants (e.g., dogfood manufacturing, sausage plants),
although much of the information can be applied to such facilities.

     While it is recognized that many pretreatment systems include
biological systems to condition meat packing wastewaters for discharge
to municipal systems under municipal regulations, these treatment
methods are not covered in this study since they are discussed in "Waste
Treatment."

     Disposal of solids—such as recovered hog hair, screenings, paunch
manure, and floatables and settled solids from grease basins—is beyond
the scope of this study, but prevention of discharge of some types of
solids and removal of other materials from waste streams are included.

     At each seminar a special panel discussion on odor control was
held. One of these sessions was taped and the proceedings are included
as chapter VI of this publication.
                               111

-------
THIS PAGE INTENTIONALLY
        BLANK

-------
                                    CONTENTS


                                                                                     Page

Preface	iii

Chapter I. Introduction	   1
    Background	   1
    Regulatory Considerations	   1

Chapter II. In-Plant Modifications To Reduce Pollution	   7
    Waste-Conservation Practices in the Meat Packing Industry	   7
    Segregation of Waste Streams	   8
    Plant Waste-Conservation Survey	   9
    Recovery of Solids and Byproducts	10
    Water and Product Conservation	12
    Selection and Modification of Process Equipment for Waste Conservation	13
    Water and Waste Conservation in Cleanup Operations	15

Chapter III.  Pretreatment of Meat Packing Wastewaters for Discharge to Municipal Systems .   .  17
    Introduction	17
    Flow Equalization	18
    Screening and Centrifuging	18
    Grease and Suspended Solids Separation by Gravity and Flotation	30

Chapter IV.  Case Histories	55
    Case 1	55
    Case 2	56

Chapter V. Summary	57

Chapter VI.  Panel Discussion on Odor Control	61
    Introduction	61
    Panel Discussion	62

References and Bibliography	83

Appendix A.  List of Equipment Manufacturers	85

Appendix B. Terms, Methods, and Devices Used in Odor Measurement and Control	89

-------
                                       Chapter  I

                                  INTRODUCTION

                                      BACKGROUND
     The importance of in-plant modification to reduce pollution (ch. II) needs no emphasis.  It is
a simple economic fact that conservation and in-plant waste saving, along with water recycle and
reuse, must be considered before any plant undertakes to build pretreatment facilities for discharge
to a public sewer, pays a municipal charge for wastewater treatment, or builds a complete treatment
plant for discharge to a watercourse.

     The importance of chapter III, "Pretreatment of Meat Packing Wastewaters for Discharge to
Municipal Systems," becomes evident in the light of a 1967 survey showing that 70 percent of the
wastewater from the meat packing industry was discharged to municipal facilities.1  Although
recent data are lacking, it seems likely that this percentage may now be slightly lower with the
continuing trend toward decentralization into small plants discharging into independent lagoon sys-
tems in semirural areas.

     Where possible, this study deals with waste conservation in existing plants.  It will be evident,
however, that many of the methods discussed are applicable largely to new plants and could not
readily be retrofitted into existing plants because of space limitations and layout. Thus, each man-
ager and engineer can use the study as a guide and checklist, evaluating each  waste conservation
concept as it applies to his particular plant.

     Chapter III discusses the  elements of equipment that make up a pretreatment plant, whether
it be an expansion of existing pretreatment facilities or an entirely new system.

     The meat plant owner, operator, or engineer needs neither a preliminary discussion of the
processes in the industry nor a separate set of recommendations for beef kill and hog kill. Accord-
ingly, it is assumed that the reader is conversant with industry practices. Figure 1-1, however, pre-
sents a packinghouse flow chart for reference.


                            REGULATORY CONSIDERATIONS

Federal

     This discussion is limited to Federal regulations relating to the subject matter of this study,
and thus does not include a discussion of permits for discharge to watercourses.

     Public Law 92-500, amending the Federal Pollution Control Act, was passed by Congress on
October 18, 1972, and contains several points of direct interest to industry.  In providing grants for
new or expanded municipal treatment plants (now amounting to 75 percent of the construction
cost), the Federal Government requires that  the municipality "has made provision for the pay-
ment ... by the industrial user of the treatment works, of that portion of the cost. . . allocable to
the treatment of such industrial wastes ..."  for which he is responsible (sec. 204(b)(l)).

-------
              WASTE
      Solid
                          Liquid
                                                                                                    PRODUCTS
                                                 Primary
                                                                             Secondary
        r
 |   Solid waste   |
    composting   .
 I    land fill
 I	J
                  '    Secondary   '
                  '    treatment   I
                  L	J
                                                                                                     Dried blood

                                                                                             Process flow

                                                                                             Waste flow
Figure 1-1. Flow chart for packinghouse.  (From North Star Research and Development Institute, "Final Report,
            Industrial Waste Study of the Meat Products Industry," EPA (Contract No. 68-01-0031.)

-------
     The law also provides that, by April 16, 1973, the EPA shall

     "issue guidelines applicable to payment of waste treatment cost by industrial and nonindustrial
     recipients of waste treatment services which shall establish (A) classes of users of such services,
     including categories of industrial users; (B) criteria against which to determine the adequacy of
     charges imposed on classes and categories of users reflecting factors that influence the cost of
     waste treatment, including strength, volume, and delivery flow rate characteristics (surges and
     maximum flows) of wastes; and (C) model systems and rates of user charges typical of various
     treatment works serving municipal-industrial communities."

Thus the EPA will be involved in the rate structure or formula developed for sewage charges for all
municipalities (including sanitary districts) where grant funds are allocated, in order to insure repay-
ment of the Government's cost in proportion to the cost of the treatment works attributable to the
industry's wastewater discharged to the municipal sewer. The following is excerpted from Federal
Guidelines— Equitable Recovery of Industrial Waste Treatment Costs  in Municipal Systems:2

     Quantity or quality formulas based on  total  cost or average unit costs: This method of cost
allocation or derivation of industrial charge is computed by several forms of the generalized formula:
where  C,- = charge to industrial users, dollars per year

       v0 = average unit cost of transport and treatment chargeable to volume, dollars per gallon

       b0 = average unit cost of treatment, chargeable to BOD, dollars per pound

       s0 = average unit cost of treatment (including sludge treatment) chargeable to suspended
           solids, dollars per pound

       Vt = volume oi wastewater from industrial Users, gallons per year

       Bf = weight of BOD from industrial users, pounds per year

       Sf = weight of suspended solids from industrial users, pounds per year

     Note: The principle applies equally well with additional terms (e.g., chlorine feed rates) or
fewer terms (e.g., v0Vf only).

     The terms b0 and s0 may include charges (surcharges) for concentrated wastes above an estab-
lished minimum based on normal load criteria.

     Inasmuch as it is an objective of the Guidelines to encourage the initiation and use of user
charges, this general method of allocation is both preferable and acceptable.

     Since this guideline was published before enactment of the act, it serves only as an indication
of possible procedures.  No guidelines pursuant to the act have been developed at this time.

     Pretreatment before discharge to publicly owned (municipality, sanitary district, county, etc.)
treatment works also is regulated under the act.  Section 307(b)(l) requires that the EPA, by
April 16, 1973,

     "publish proposed regulations establishing pretreatment standards for introduction of pollutants
     into treatment works . . . , which are publicly owned, for those pollutants which are determined

-------
     not to be susceptible to treatment by such treatment works or which would interfere with the
     operation of such treatment works.  Not later than 90 days after such publication, and after
     opportunity for public hearing, the Administrator shall promulgate such pretreatment
     standards."

The act allows a maximum of 3 years for compliance by industry, and also provides for revision of
these standards as new technology warrants.

     The limits may be anticipated to be in two general categories.

     • Prohibited items (such as ashes, hair, whole blood, paunch manure, and similar materials
       untreatable in municipal plants)

     • Maximum concentrations of such items as biochemical oxygen demand (BOD), suspended
       solids, and other constituents that, in excess, could interfere with the operation of the
       municipal plant

Many municipalities will use such maximums in their structure of charges, figuring a volume cost
per 1,000 gallons per month (perhaps on a sliding scale similar to water billing or, more conveniently,
a definite multiplier of the municipal water bill).  To this volume cost, surcharges are added for BOD,
suspended solids, grease, and possibly other pollutional ingredients at a determined rate in cents per
pound of each such pollutional ingredient beyond a certain basic concentration, the base being
representative of the concentration of domestic sewage.


State

     This discussion will be limited to the State's role in in-plant conservation and pretreatment be-
fore discharge to public sewers. Recycling and reuse of water, and any other major in-plant changes,
should be reviewed with the State meat inspection agency if the plant is under State, rather than
Federal, inspection.

     Approval of plans for pretreatment of wastewaters before discharge to public sewers may be  a
requirement under the State regulations for approval of plans for sewage treatment. States differ on
this point.

     In some States, the plant may also be required to have a State-licensed wastewater-treatment-
plant operator for such pretreatment facilities.

     Municipal ordinances relating to wastewater generally are reviewed by the State stream-pollution-
control authority. Thus, ordinances and regulations regarding industrial wastewater and charges and
surcharges most likely will be reviewed by the State before passage.

     If the city has not passed the legislation required by the EPA for a Federal grant for sewage-
treatment construction, the State  (which allocates these funds) may advise EPA to withhold a por-
tion  of the grant until all requirements are met.

     When a new plant is planned for connection to a public sewer, and such connection substantially
will increase the flow or pollutional characteristics of wastewaters reaching the municipal wastewater-
treatment plant, the agency owning the sewer is required by Federal law to advise the State of such
change.

-------
Municipal

     Municipal ordinances and regulations that are less stringent than those set up under the Federal
act, discussed earlier, will require alteration to conform; but if they exceed the Federal standards,
they need not be reduced unless the city elects to do so.

     Existing municipal ordinances and regulations covering discharge to the public sewers vary
widely. A large number of cities use, as a guide, the so-called Model Ordinance, published as part of
Manual of Practice No. 3 of the Water Pollution Control Federation.  Article V of the Model Ordi-
nance contains an extensive list of limiting characteristics applicable to meat packing wastewaters
discharged to public sewers.3

     Municipal ordinances generally cover the subject under two headings, limitations and surcharges.

     Limitations. Prohibition of objectionable matter: Various minerals, toxic materials, and waste
characteristics and materials that are difficult to treat are  excluded.  The following examples are
typical:

     • The Metropolitan Sanitary District of Greater Chicago includes the following exclusions on
       ingredients that may affect packing plant effluents:

       — Noxious or malodorous liquids, gases, or substances that either singly or by interaction
          with other wastes are sufficient to create a public nuisance or hazard to life, or are suffi-
          cient to prevent entry into the sewers for their maintenance and repair

       — Solid or viscous  wastes that cause obstruction to the flow in sewers or other interference
          with the proper  operation of the sewerage system or sewage treatment works, such as
          grease, uncomminuted garbage, animal guts or tissues, paunch manure, bone, hair, hides,
          and fleshings

       — Waters or waste  containing substances that are not amenable to treatment or reduction
          by the sewage treatment process employed, or are amenable to treatment only to such
          degree that the sewage treatment plant effluent cannot meet the requirements of other
          agencies having jurisdiction over discharge to the receiving waters

       — Excessive discoloration

     •    Other cities use similar limiting clauses in their ordinances, often copied from the Manual
          of Practice No. 3, from which the above wording was adapted in part.

     Concentration of pollutional characteristics:  The Ordinance of the Metropolitan Sanitary
District of Greater Chicago provides no top limits for BOD or suspended solids, but does include
surcharges for these items (see "Surcharges").  It does, however, limit temperature to a maximum
of 150° F (65° C) and fats, oils, or greases (hexane solubles) to a maximum of 100 mg/1. These
limits are included in many municipal ordinances. Other cities may limit BOD to possibly 300 mg/1
and suspended solids to 350 mg/1, more or less. Catchall clauses also are common; for example,
"The Town Board of Trustees is authorized to prohibit the dumping of wastes into the Town's
sewage system which, in its discretion, are deemed harmful to  the operation of the sewage works of
said Town."
         "Regulation of Sewer Use," Manual of Practice No. 3, is available at $1.50 ($1 to Federation members)
from the Water Pollution Control Federation, 3900 Wisconsin Avenue, N.W., Washington, D.C.  20016. A 15-percent
quantity discount is available in lots of 12 or more copies.

-------
     Surcharges. The Metropolitan Sanitary District of Greater Chicago charges 2.1 cents per 1,000
gallons, 1.4 cents per pound of BOD, and 2.4 cents per pound of suspended solids, after deducting
the first 10,000 gal/day (and the BOD and suspended solids it would contain).  Also deducted are
the sewer district tax (a property-type tax) plus 4 mills per day per employee, an allowance for
sanitary sewage discharged during the working day.

     Most of the simpler sewage billing systems are based on the water use, ranging from about 50
percent to as high as 125 percent of the water billing, with maximums for BOD, suspended solids,
grease, and sometimes other ingredients. These are basic sewer charges applicable to all users-
domestic, commercial, and industrial—and are not classified as surcharges unless they include escala-
tion for BOD, suspended solids, grease, and so forth, and possibly flows, in excess of a "domestic"
base.  Thus the surcharge portion of the ordinance might be similar in structure to the Chicago
ordinance, but with a charge for flow in excess of a base, and a charge per pound of ingredients
above a base represented by discharge from a single residence.

     Also see the Federal guidelines discussed earlier.

     In general, the new Federal act may radically modify existing municipal ordinances and regula-
tions.  It should also be noted that recycle and reuse of used water must be checked by the U.S.
Department of Agriculture and by any other agency having jurisdiction over product sanitation.

-------
                                      Chapter  II

                          IN-PLANT  MODIFICATIONS

                            TO  REDUCE POLLUTION

         WASTE-CONSERVATION PRACTICES IN THE MEAT PACKING INDUSTRY

     Except for very small slaughtering plants, most plants recover blood, screenable solids, and
grease by various in-plant systems and devices. Many small packers without blood-drying facilities
or inedible-rendering departments recover such materials for local tank truck pickup operated by
specialized byproducts plants in the area.

     The quantity of water used varies widely, based on waste-conservation practices, blood- and
solids-handling methods, and the amount of processing done in the plant. This quantity may range
from about 0.5 to 2 gal/lb live weight killed (LWK).

     The degree of wastewater conservation, recycle and reuse, and solids and blood recovery in
each individual plant depends on many  factors:

     •  Age of the plant

     •  Views of management

     •  Whether markets or final disposal facilities for recovered blood, solids, and grease are readily
       available

     •  Market prices of the recoverable materials

     •  Local regulations regarding effluent quality and surcharge costs for plants discharging to
       public sewers

     •  The first cost, and operating costs of independent treatment if the packer discharges to a
       watercourse

     The low market price for recovered inedible grease in some localities has forced many packers
to dispose of it as feed-grade grease. If the meat packing plant is located  conveniently near a soap
plant, the possibilities of an  improved price will provide special incentives for grease recovery.
Variations in economics in disposing of the solids and concentrates such as paunch manure, blood,
hair, casing  slimes, and concentrated stick (in wet rendering) inevitably affect the diligence with
which these pollutional solids are kept out of the sewer.

     The limitations and surcharge regulations for wastes discharged to city sewers, however, or the
cost of complete treatment if the plant  discharges to a watercourse, must be evaluated carefully to
establish the level of waste conservation appropriate to the packing plant. For example, a plant
discharging  to its own anaerobic-aerobic pond system may find that some floatable inert solids,
such as stockpen bedding, can improve the insulating scum blanket on the anaerobic lagoon. In this
case neglect in recovery of such materials would  not be important. On the other hand, a packing
plant in Springfield, Mo., faced with a municipal waste-treatment charge of $1,400 a month, modi-
fied its production processes (including  solids recovery) so that the monthly payment dropped to
$225.

-------
     In processing and in quality control, the meat industry finds water an essential tool to help
cleanse the product and to convey and remove unwanted materials.  But in wastewater handling,
water becomes a problem—a diluter that flushes and dissolves organic matter and carries it to the
sewer. Wastewater treatment is basically nothing more than a processing system to separate the
organic and inorganic matter from the water that collected it.

     The goal of every wastewater engineer is to remove organic solids "dry," without discharging
to the sewer, and then use an absolute minimum of water for the essentials of sanitation. The
nearer this goal, the simpler becomes the wastewater problem.  This  goal provides the pattern in
waste conservation in the plant, and  can be summarized briefly in the following axioms:

     • Use water wisely—only enough to get the job done.

     • Keep waste solids in bulk whenever possible, for disposal as a solid or as a concentrated
       sludge, without discharging to the sewer.

     • Clean with high pressure and minimum water volume (small hoses).  Use the right detergents
       in the right proportions to clean well with minimum rinsing.

     • Recycle water as much as possible, within the limits of U.S. Department of Agriculture
       regulations.  Some reconditioning, such as cooling or screening, may be necessary for
       recycling in some instances.

     • Use the minimum pressure and volume for washing product,  consistent with quality con-
       trol. High pressure in washing product may drive soil into the product and also wash away
       valuable edible protein and fat.

     • Control volume, temperature, and pressure automatically. Dependence upon manual regula-
       tion can lead to waste.

     • Use valves that shut off automatically when the water is not  needed. For example, photo-
       electric cells are used in Japan to turn water on when product is in a washing position.

     • Study each process independently.  General rules alone will not do the job.


                           SEGREGATION OF WASTE STREAMS

     In meat packing, it has been common practice to provide separate sewer systems for grease
wastes, nongrease (variously termed  "manure" sewer or "red" sewer), clear waters from chilling,
condensing, and cooling operations,  surface and roof water (surface drainage), stockpen wastes, and
sanitary wastes.  For new plants, however, further segregation often  is desirable in order to permit
removal of pollutional ingredients before the wastewaters mingle with other plant waters.  Screen-
ing equipment can be smaller and can be designed for the special solids present.  In some cases, such
segregated waters may be sufficiently dilute to use for recycling.

     In the interests of dry or semidry manure separation, a separate manure sewer should be pro-
vided in new plants for all sources of manure.  This waste can be pretreated by screening, followed
by dissolved air flotation. The floated solids can be analyzed for fats and wet rendered if warranted.

     The grease sewer should receive only those wastes that contain  grease.  If the color of the
rendered tallow is a factor, special diligence must be exercised that all manure-bearing wastes be
kept out of the sewer. The settled solids should be discharged over a screen, dried, and used in
feeds, if possible. These solids contain a significant amount of grease.  Basically, the grease sewer

-------
should receive wastes from boning, cutting, edible and inedible rendering, casing washing (after
manure and slime have been removed), canning, sausage manufacturing, slicing, prepackaging,
smoking and smoked meats hanging, cooking, tank car loading and washing, carcass coolers, lard
and grease storage areas, equipment washrooms, pickling areas, and the like.

     The conventional nongrease sewer receives wastes from hog scalding, dehairing, tripe washing,
chitterling washing, and kill drains up to and including the polisher. It also receives the flow from
manure recovery systems when a separate manure screen is not provided.

     Hide-processing waters commonly are recirculated with or without screening for solids reduc-
tion.  If these waters must be dumped, they should be screened separately and then discharged to
the nongrease sewer.

     Vapors from cooking and rendering operations can be cooled and condensed through heat
exchangers and recycled to driers, or sent to the grease sewer.

     All clear water (jacket-cooling water, air conditioner water, steam condensate, and chill water)
should be separated carefully for reuse.

     Curing pickle (undiluted) has a very high BOD and should be reused whenever possible. Run-
off pickle from processing should be caught in recycling pan systems as part of the injection equip-
ment.  In a recent study, it was found that only 25 percent of the pickle produced was retained in
the product, the rest was lost by general leakage and spilled from the injection machines.  The BOD
of pickle varies, but the dextrose alone has a BOD of about 660,000 mg/1.

     Sanitary wastes are, of course, discharged directly to the  city sewer or to a separate treatment
system, and should not enter any pretreatment elements.

                        PLANT WASTE-CONSERVATION SURVEY

     The first step in waste conservation is a well-organized and well-executed waste-conservation
survey, backed by management. The following elements would be part of the basic survey.

     First the engineer should collect data on the volume, nature, and general facilities of the busi-
ness.  If he  is a company employee, he already has this information. In addition, he should know
all plans for future construction.  He should attempt to develop a 10-year forecast of business. If
the wastewaters discharge to a city sewer, he should know something about population  trends in
the area, the possibilities of industrial growth, and whether such growth will add load to the munici-
pal plant. Whether the wastewaters discharge to a public sewer system or to the packer's private
treatment plant, the engineer should be familiar with the system and the sewage treatment plant
and with the requirements for the receiving stream.

     The approach to wastewater control need not be complicated or expensive. The principal
effort should be applied toward preventing product (and contaminants) from  entering the waste
stream and reducing water use to a minimum. High waste-load areas should be probed first.
Accurate sampling, chemical analysis, and flow measurements  need not be performed initially, but
can be deferred until after the gross problems have been solved.

     Since most suspended solids in meat wastewaters are organic, their removal results  in a reduc-
tion of BOD.  Suspended solids concentrations (after screening) are a rough measure of  BOD and
can be measured easily and quickly.  Dissolved solids can be measured with  a conductivity meter.
Red color indicates the presence of blood, a very large contributor of BOD. A simple jar test will
give some information.  During the initial phase of in-plant waste control, approximate figures are
sufficient.  Flows must be measured at the time of sampling.  Flows can be estimated, or it is

-------
simple to catch the flow in a pail or 50-gallon drum for a period of time.  The'gallons per minute
can be calculated. In some instances it may be necessary to break into a sewer line or disconnect a
pipe to obtain a sample or flow measurement.

     Solids per unit volume, with associated water consumption, will give a measure of the pounds
of organic wastes generated. Problem areas then can be studied for methods of control.  In many
cases, a small outlay of money will effect substantial waste control.  Records should be kept to
follow progress.

     Table II-l lists waste-load ranges to provide a rough guideline. These ranges are broad because
they include small and large operations—some small plants with no inedible rendering and no blood
recovery, and others with a broad line of meat processing, with inedible rendering and blood
recovery.

            Table 11-1.—Typical plant waste generated per 1,000 pounds live weight kill, all species
            BOD	
            Suspended solids
            Grease	
            Flow	
4 to 18 pounds
3 to 17 pounds
1.5 to  12 pounds
600 to 2,000 gallons of water
     The following equation can be used to convert laboratory analyses and flow to pounds per
1,000 pounds LWK:

                                                    flow in gallons X 8.34 X mg/1
            Pounds pollutant per 1,000 pounds LWK =   1,000 Ib LWK X 1,000,000

where mg/1 = milligrams per liter from laboratory data.

     Anyone interested in typical flow, BOD, suspended solids, and grease from various processing
operations will find useful data in Industrial Wastewater Control.3 These values vary widely from
plant to plant; thus, it will be most useful to cite methods of correction without attaching specific
values to each process or process change. The order of priorities for in-plant waste conservation will
vary depending on the results of the waste-conservation survey in each individual plant.


                        RECOVERY OF SOLIDS AND BYPRODUCTS

Blood

     Blood has the highest BOD of any liquid material emanating from meat processing.  It has an
ultimate BOD (approximately 20-day) of 405,000 mg/1.4  Customary analytical methods for 5-day
BOD (BOD5) are not sufficiently accurate in these high ranges, but are estimated to average from
150,000 to 200,000 mg/1. Considering that one head of cattle contains approximately 49 pounds
of blood, the BOD5  of blood from a single animal is about 10 pounds, as against about 0.2 pound
BOD5 discharged per person per day.

     Thus, if the blood from a single animal killed in a day is discharged to the sewer, its pollutional
load would be equivalent to that of 50 people.  Clotted blood (about 70 percent of the total) has a
BOD (ultimate) of about  470,000 mg/1, while the liquid portion is about 200,000 mg/1.4 Comparing
these figures with  the ultimate BOD of domestic sewage, about 300 mg/1, it is evident that blood
conservation pays.
                                            10

-------
     The curbed bleeding area that discharges to the blood tank should be as long as possible, and
the blood should be squeegeed to the blood tank before the valves are switched to drain to the
sewer for the cleanup operation. The floor and walls then should be cleaned with a minimum of
water by use of small-diameter hoses. If the water used in the first rinse is held down to 30-50
gallons, it can be discharged to the blood tank as an added conservation measure.  The additional
cost of evaporating this quantity of water will, in most cases, be far less than the cost of treating it
as wastewater.

     Water is sometimes mixed with blood to facilitate transportation in pipes. The evaporation of
this added water in the drier adds expense and often can  be eliminated if the drain from the bleed-
ing area to the blood tank is large enough and the blood tank is located to permit  a straight drop
into it. If the blood is pumped to the tank, the piping layout should be checked.  If sewer alinement
cannot be improved to prevent drains from clogging, decoagulating electrodes can be installed to
prevent coagulation (see app. A). Troughs to catch and convey blood should be pitched and curved
to facilitate squeegeeing before washing.

     Blood-processing methods are important in waste conservation. For lowest losses to the sewer,
continuous driers are most common, using a jacketed vessel with rotating blades to prevent burn-on.
Continuous ring driers are also popular. They produce a relatively small amount of bloodwater that,
in small plants, usually is discharged to the sewers. The bloodwater can be clarified further by dis-
charging it through a small settling tank. This waste-conservation problem warrants further study.
The older steam coagulation systems are more serious problems in waste conservation, because a
substantial  amount of fines can be lost when the coagulated blood is screened. A  combination of
paunch manure solids and bloodwater can be cooked to produce a hydrolyzed hair stick, but the
process economics should be explored before a packer embarks on such a project.5 Casing slimes
can be added to the blood drier if desired, or can be dried with other product in conventional
inedible dry rendering.


Paunch Manure

     Paunch manure is either wet or dry dumped for recovery of tripe. Wet dumping consists of
cutting the paunch open in a water flow, discharging to a  mechanical screen, and thence to the
manure sewer. This washing action carries a large fraction of the BOD from the paunch waste solids
into the water phase. Paunch solids are about 75 percent  water, weigh about 50 to 60 pounds per
animal, and have a "dry dump" first-stage BOD of over 100,000 mg/1 (BOD5 slightly less). Eighty
percent of this BOD is soluble.

     Dry dumping consists of dry discharge of the manure solids down a chute to  an inedible area
for ultimate disposal as a waste solid or for blending to produce  a marketable solid.  After dry
dumping, fines are removed by washing and are discharged into the manure sewer.

     Stomach and peck contents may contain undigested  grains  that contain proteins and fats. An
investigation may disclose that these materials can be routed directly to a drier, unopened, if the
resulting product is acceptable as an ingredient in the end product (see also discussion  in "Hasher-
Washer Screen").


Casing Saving

     Casing-saving operations contribute substantially to pollution. Waste from the deslimer should
be passed directly to cookers in inedible rendering or dried with the blood. A  small catch basin in
the immediate casing area will recover sizable amounts of  good-quality fats.  Water should be kept
                                            11

-------
at a minimum.  Sprays should be checked for efficiency in volume of water used, proper design,
proper direction, and maximum spacing.


Stockpen Wastes

     Stockpen wastes are high in nutrients and should be segregated in a manner to allow alternative
methods of disposal. Pens should be dry cleaned and the waste should be hauled away for land
disposal.

     Usually runways and pens are hosed down periodically. Consideration should be given to
segregation of this strong liquid waste for disposal by trucking or piping for disposal directly on
farmland, within the limits of regulations regarding land disposal.


Scraps and Bone Dust

     Plant operations in cutting and trimming should be examined carefully for opportunities to
intercept waste solids before they enter the sewer.  Scraps and liquids from the hog-neck washer
should be caught in a container directly beneath the washer. Some form of grease  trap can suffice.
Collected contents should be routed direct to rendering. Bone dust from sawing operations is an
important source of pollution and contains a high concentration of phosphorus.  Bone dust is of
fine texture and when diluted with water is difficult to recover.  It should be recovered intact by
catching directly in containers, or by sweeping up and hauling to the inedible rendering department.


Hide Curing

     Hide-curing operations are becoming increasingly involved as segmems of tanning operations
are transferred from tanneries to beef-slaughtering plants. During winter months, a single hide can
contain 60 pounds of attached lumps of manure, mud, and ice. In addition, salt, caustic, acids, and
fleshing waste enter the sewage stream.  The wash water should be recycled, or retained for separate
treatment (usually screening) if considerable volumes are involved.


Disposal of Tank Water

     If lard is wet rendered, or if any inedible wet rendering is in service at the plant, the disposal
of tank water may be a problem (BOD about 22,000 mg/1). In processing lard by low- or medium-
temperature continuous rendering, one process uses about 150 pounds of water (as steam) per 230
pounds wet-rendered product.  There is, however, a market in some areas for 50- to 60-percent
edible stickwater produced by evaporating this tank water.  In another process, less water is used
and it goes out with the cracklings.  In contrast, inedible tank water is evaporated and is commonly
blended with animal feed as inedible stickwater.  Under no circumstances can this high-BOD waste
be discharged to the sewer.  In some cases, the tank water can be trucked to a central processing
plant for evaporation. It can also be dried with inedible solids.


                         WATER AND PRODUCT CONSERVATION

     Water conservation is an essential part of an in-plant wastewater-control program. It has been
shown that packing plants using the most water per animal generate the most waste per animal.
Excessive washing, especially with hot water, removes juices and tissues from product and flushes
them into the sewers. Water use can be reduced at many locations.
                                             12

-------
     The viscera-pan sterilizer and the final carcass washer are large water users. These washing
operations should be modified so that when the carcass chain stops the water automatically shuts
off.  This modification can be made using solenoid-operated valves under control of the conveyor-
chain motor starter. The viscera-pan sterilizer uses large amounts of 180° (F) water. The sterilizer
often runs continuously during the workday (and during the cleanup period). Thought should be
given to engaging the services of those skilled in spraying techniques—not only to design the
sterilizer for economy in water use but also to design cleaned-in-place (CIP) cleaning systems for
the viscera pans (see "Automatic CIP Cleaning").  The sprays on the final carcass washer should be
checked for proper spacing, direction, shape of spray, pressure, and water consumption.


SELECTION AND MODIFICATION OF PROCESS EQUIPMENT FOR WASTE CONSERVATION

Chitterling Washers

     Chitterling washers  can be improved by fitting them with limiting orifiqes and spray nozzles
rather than drilled pipes. Water consumption can be reduced from 130 to 70 gal/min by proper
design of sprays and control of water and pressure on these units.3


Hog-Casing Cleaning Machines

     These machines can be modified to recover the slime from the stripper, which amounts to 0.2
pound of dry solids per hog.3


Scalding Tub

     A means of slow drainage of the scalding tub and separate removal of the sludge will reduce
the waste concentration materially. It is reported that 100 hogs, at maximum slaughter rate, pro-
duce 11.2 pounds of BOD and 23.5 pounds of suspended solids.3 It may be expected that as much
as 30 percent of the BOD and 80 percent of the suspended solids will settle in the tub.   The scald-
ing tub can be fitted with a perforated riser pipe in the drain, extending about 6 inches above the
floor of the tub.  The residual sludge can then be squeegeed through a 12-inch-square sluice gate at
tank-floor level and discharged to a truck for disposal as waste solids.


Edible Rendering

     Low- or medium-temperature continuous edible rendering can be accomplished with a limited
amount of water discharged to the sewers. This factor should enter the cost analysis when  a new
system is purchased. See "Disposal of Tank Water," discussed earlier.


Hasher-Washer Screen

     It is not uncommon to eliminate the hasher-washer screen.  The entire product can be dry
rendered if the quality of the rendered product is not a sensitive consideration. The added  bulk in
dry rendering is small when balanced against increased yield and the elimination of the hasher-
washer screen drainage (see discussion of "Paunch Manure").
                                            13

-------
Automated CIP Cleaning

     For daily cleaning, consideration should be given to automated cleaning of viscera pans, tank
trucks, continuous rendering systems, conveyor tables, piping, cookers, and driers.  Systems that
will conserve water and labor are available from detergent manufacturers.


Heart Washers

     A considerable amount of raw water is used to chill hearts in modern heart washers.  A study
of this operation may prove that the use of refrigerated chill water will conserve water and result in
a better shelf-life product.


Offal Areas

     In the offal areas, continuous streams of water sometimes are used to aid in moving product
down chutes. Special sprays or redesign of chutes will reduce water use at these points. Any sprays
made up of a pipe with drilled orifices are usually inefficient and should be replaced with engineered
sprays, designed for minimum water consumption, proper pressure, and maximum effective cover-
age.  Master shutoff valves can be used to shut groups of sprays during rest periods. Ball-type valves
are effective for this service.
Knife and Sterilizing Boxes

     Knife and sterilizing boxes often are operated with excessive amounts of water and temperature.
The use of electric temperature-controlled knife boxes should be considered—particularly in coolers
where steam causes condensation problems and refrigeration losses.


Sanitary Facilities for Personnel

     Press-to-open valves (foot or knee operated) should be used on all lavatories.  Drinking foun-
tains should not run continuously.  Refrigerated water fountains will conserve water.


Animal Drinking Water

     Animal drinking water should be minimal, but consistent with satisfactory yields.  In the past,
it was believed that abundant drinking water was necessary for good yields; consequently, drinking
troughs flowed continuously. Recent information indicates that animals can go 1 or 2 days
without water and show negligible yield reduction.  Timeclock control of the master valve for
drinking water supply, programed for 1 minute on and 4 minutes off, will reduce water use by 80
percent.


Raw Water Recycle and Slowdown Water

     Once-through raw water in refrigeration condensers and compressor cooling jacket water are
expensive. Such water should be either reused in plant processes or recycled through heat-
exchanging devices—cooling towers or evaporative condensers. Evaporative condensers are usually
the most feasible.
                                             14

-------
     If possible, blowdown water should be returned to the soil because of its high mineral content.
Generally, regulated quantities can be discharged to the city sewer directly without violating limit-
ing regulations. Boiler blowdown water is "soft water" and can be reused in cleanup operations
or in fabric wash machines. Some experimentation is required to develop a proper blend of plant
water supply with the blowdown water, particularly relating to temperature.
Manual Washing

     Manual washing of meat and offal products can be improved. Washing operations requiring
under-the-spray time of less than 50 percent should have press-to-open sprays.  On-site observations
have disclosed many hand-washing operations (particularly offal) with time under the spray of not
more than 10 percent.  Sprays should not flow unattended at work tables. In addition to press-to-
open spray valves, efficient redesign of spray heads will improve product cleaning and conserve
water.  Pressures and volume of flow should be controlled with pipe restrictions or locked valves to
establish a minimum consistent with quality results. Photoelectric cells could serve well as auto-
matic control.
Dry Rendering

     In dry-rendering systems, many plants mix raw cold water with cooking vapors from rendering
driers to condense vapors and reduce odors.  This mixture is discharged to the sewer.

     A recent study of a typical operation disclosed that each drier used 120 to 130 gal/min of
water, and the mixture contained 118 mg/1 of BOD and 27 mg/1 of grease. It is likely that the BOD
and grease were carried over from overloaded driers. The water consumption represented 40 percent
of the entire plant water. A heat exchanger was recommended for direct water condensing to
eliminate the cooling-water loss. Heat extracted from the vapors can be removed by m'eans of a
cooling tower or returned to  the plant hot water system. Commonly, cooking operations closely
follow killing operations; thus the recovered heat can be reused.

     In some instances a portion of dissolved-air-flotation cell effluent is routed to the inedible
cooker vapor condensers. Details on dissolved air flotation are given in chapter III, "Static Screens"
and "Vibrating Screens."

     Condensed cooking vapors from dry-rendering operations should be routed to the fat-bearing
stream if they contain a significant amount of recoverable solids.


             WATER AND WASTE CONSERVATION  IN CLEANUP OPERATIONS

     Old-fashioned cleanup operations usually use excessive amounts of water, hot and cold.  Many
cleanup hoses discharge .10 to 20 gal/min of high-velocity, 140°-180° hot water. Some operators
believe that a flood of hot water for cleaning floors and equipment is necessary. Not only is indis-
criminate use of hot water undesirable from a wastewater-control standpoint, but such practice
erodes floors and Walls, removes lubrication from equipment, and can cause electrical failures.

     It is altogether too common for cleanup men to remove floor-drain grates and flush meat
scraps down the drain, believing that a screen or catch basin will trap all solids. By the time the
scraps are recovered, they have been broken up in the flow and much of the organic matter has
been dissolved or suspended in the wastewater to the extent that it cannot be removed without
complete treatment—by the packer or by the city.  What started as a removable scrap has become
a part of a wastewater-treatment load.


                                            15

-------
     Floors and equipment should be dry cleaned before hosing and scraps taken to the inedible
rendering. This first step in cleanup requires rigid surveillance.

     Smaller nozzles on smaller hoses and application of modern cleaning methods will reduce
water. For example, a kink-type valve, which is inserted in the hose and opens only when the hose
is bent, will automatically stop the water when the operator drops the hose. Water should be con-
trolled automatically to maintain the lowest temperature, lowest volume, and highest pressure con-
sistent with each cleaning job.  Effective detergents to emulsify fats and lift proteins and soil will
reduce the quantity of rinse water required. Well-qualified cleaning consultants are available for
guidance.

     As discussed earlier, the use of automated CIP systems will reduce and control water use.
                                             16

-------
                                     Chapter  III

        PRETREATMENT  OF  MEAT  PACKING WASTEWATERS

               FOR  DISCHARGE  TO  MUNICIPAL SYSTEMS

                                    INTRODUCTION

Advantages and Disadvantages of Pretreatment

     Although compliance with municipal regulations regarding the quality of a meat packer's
wastewater for discharge to the city's sewer usually will determine the degree of pretreatment,
there are some factors that may encourage pretreatment beyond the levels required by ordinance.

     • A higher quality of pretreatment may be justified economically if the city's charges and
       surcharges are at a level where some additional pretreatment becomes economically
       advantageous.

     • The meat packer may prefer to assume treatment responsibilities to avoid complaints
       from the municipality.

     • There may be indications that the future will bring increases in the city's rate structure.

     • Grease and solids may have a good market  in the area. Proximity of a soap plant or
       similar grease market may produce economic advantages for grease recovery, or may war-
       rant some expense in improving quality of  the finished inedible grease or tallow. Such
       improvements will also improve the wastewater effluent.

     Following are some disadvantages in pretreatment:

     • The pretreatment will be placed  on the property tax rolls, unless State regulations permit
       tax-free waste treatment for industry.

     • The maintenance, operation, and record  keeping may be expensive or burdensome.

     • The burden of good operation increases as  the treatment becomes more complex and
       extensive.
Evaluating Needs

     After the plant has been surveyed completely, and all possible waste conservation and water
reuse systems have been cataloged, the necessary pretreatment system must be designed and the
cost estimated. .Those parts of the treatment attributable to flow (such as grease basins and dis-
solved air flotation) should be totaled and reduced to a cost per 1,000 gallons. Similar breakouts
in costs per pound can be carried out for grease, suspended solids, and BOD.

     Then each major in-plant expense for waste conservation and water recycle and reuse can be
evaluated, based on the estimated reduction in flow,  BOD, suspended solids, and grease.  From
such data, priorities can be established for each in-plant waste-conservation measure suggested in
the survey.
                                           17

-------
     The future planning for the meat packing plant should serve as a guide to determine piping
arrangements and suitable locations (and sizes) for projected facilities.


Costs

     Waste-saving and treatment costs should be charged back to the department from which the
flow, BOD, suspended solids, and grease emanated. Selected costs of some of the equipment com-
mon to pretreatment will be discussed later.


                                  FLOW EQUALIZATION

     Equalization facilities consist of a holding tank and pumping equipment designed to reduce
the fluctuations of waste streams.  These facilities can be economically advantageous whether the
industry is treating its own wastes or discharging into a city sewer after some pretreatment.  The
equalizing tank will store wastewater for recycle or reuse, or to feed the flow uniformly to treat-
ment facilities throughout the 24-hour day.  The tank is characterized by a varying flow into the
tank and a constant flow out. Lagoons may serve as equalizing tanks or the tank may be a simple
steel or concrete tank, often without a cover.

     Advantages of equalization for the meat packer discharging to a city sewer are

     • In-plant pretreatment can be smaller, since it can be designed for the 24-hour average,
       rather than the peak flows.

     • The city may have penalties for high peaks that can be avoided by equalization.

     The disadvantages are few.

     • More equipment to maintain and operate

     • Additional fixed costs


                            SCREENING AND CENTRIFUGING

Introduction

     Because so much of the pollutional matter in meat wastes is originally solid  (meat particles
and fat) or sludge (manure solids), interception of the waste material by various types of screens
and centrifuges is a natural step.

     Unfortunately, when these pollutional materials enter the sewage flow and are subjected to
turbulence, pumping, and mechanical screening, they break down and release soluble BOD to the
flow, along with colloidal and suspended and grease solids. Waste treatment-H;hat is, the removal
of soluble, colloidal, and suspended organic matter—is expensive. It is far simpler and less expen-
sive to keep the solids out of the sewer entirely.

     But, because in-plant conservation is at best imperfect and people are fallible, final organic
solids separation in the main effluent sewer generally is employed.  Various combinations of
facilities for pretreatment may be selected, including screening, gravity grease and solids separation,
dissolved air flotation, and biological treatment of various types.6
                                            18

-------
                                                                           1 - Paunch manure screen
                                                                           2 = Kill-floor wastewater screen
                                                                           3 = Hair removal screen
                                                                           4 = Blood screen
                                                                           5 - Cooker tankage screen
                                                                           6 = Crackling or fluff screen
                                                                           7 - Cooker tankage screen
                                                                           8 - Bone-scalping screen
                                                                           9 - Bone-sizing screen
                                  Balance of plant is same
                                  as a continuous plant
                          _/  To centrifuges


                             Figure 111-1. Complete meat-processing plant.
To shipping
     The information in this discussion of screening and centrifuging can be applied both for in-
plant waste conservation and waste treatment.

     Figure III-l shows where screens might be used throughout the plant. While vibrating screens
are shown, other types of screens could be suitable for service in the locations cited. Whenever
feasible, pilot-scale studies are warranted before selecting a screen, unless specific operating data
are available for the specific use intended, in the same solids-concentration range and under the
same operating conditions.


Static Screens

     During the past several years, a substantial  number of so-called static screens have been in-
stalled in many process industries to recover suspended matter from plant effluents or liquid flows
within a plant. Highly successful screening operations have been achieved in the meat packing,
tanning, canning, textile, and paper and board products industries, as well as in domestic sewage-
treatment operations. Interesting new developments are underway, such as the treatment of
wastes from animal-producing farms and poultry-processing plants.

     In most instances, the  installed equipment represents new functions or concepts in recovery
and generally involves recycling or some other use of the recovered solids.  In many cases, sta-
tionary screens are installed as replacements for  screens that require moving parts to make a suit-
able separation of solids from a process stream.
                                               19

-------
                  Figure 111-2. Single Hydrasieve screen operating on industrial wastewater.
     Basic Design Concepts.  The primary function of a static screen is to remove "free" or trans-
porting fluids. These fluids can be removed by several means and, in most older concepts, only
gravity drainage is involved. A concave screen design using high-velocity pressure feeding was
developed and patented in the 1950's for mineral classification, and has been adapted to other
uses in the process industries.  This design employs bar interference to the slurry, which knifes off
thin layers of the flow over the curved surface.

     Beginning in 1969, U.S. and foreign patents were allowed  on a three-slope static screen made of
specially coined curved wires. This concept used the Coanda or wall attachment phenomenon to
withdraw the fluid from the under layer of a slurry stratified by controlled velocity over the
screen. This method of operation has been found to be highly effective in handling slurries contain-
ing fatty or  sticky fibrous suspended matter.

     Since the field tests to be reported were conducted on the later design of stationary screen,
details of this unit are presented here.  The device is known commercially as a Hydrasieve.  A typical
installation of a single screen operating on industrial wastewater is illustrated in figure IH-2.
                                              20

-------
      (a)
               (b)
                     Gravity feed
                     of liquids/solids I
      Self cleaning,
      hon clogging stainless
      steel screen for
      continuous dewatering
Headbox
                                            Alternate
                                            feed inlet
                                                                                   Liquid
                                                            Solids
        Figure III-3, (a) Diagram showing path of slurry screened by Hydrasieve. !b) Segmented section
        of screen wires with slurry in contact with upper end of Hydrasieve. (c) Screen design of Marvel'
                                           Hydrasieve.

     Method of Operation.  The slurry to be screened or thickened is pumped or may flow by
gravity into the headbox of the machine. As shown in figure III-3(a), the incoming fluid overflows
the weir above the screen area and is accelerated in velocity and thinned in depth as it approaches
the screen.  A lightweight hinged baffle is incorporated into the assembly in such a position that
it reduces turbulence in the flow.  Turbulence is reduced by the shape of the foil, which causes the
fluid to respond to Bernoulli's theorem through the wedge-shaped entrance. The increasing
velocity of fluid draws the baffle toward the surface of the screen.

     Suspended solids tend  to stratify in the thin stream, and fibrous materials aline themselves
lengthwise with the direction of flow. Figure III-3(b) shows a segmental section of the screen wires
and the slurry as it comes in contact with the upper end of the Hydrasieve screen.  Note that the
                                              21

-------
wall attachment of the fluid to the metal bars or wires draws or bends an under portion of the flow
through the openings.  Part of the underflow also moves along the arcuate surfaces of the wires,
and is concentrated primarily at the apex of the downward curve. Here this flow falls by gravity
from the screen back or flows in streams attached to the underside of the wire assembly in a central
path between the supports. The screen pattern permits a maximum of fluid extractiojrx based on
the limit of flow rate and screen area.  Figure III-3(c) illustrates the screen design which is regis-
tered under the trademark Mar-Vel'.

     On the first (top) slope of the screen, most of the fluid is extracted from the bottom of the
stream traveling at 25° from the vertical. When the angle of the screen changes to 35°, some addi-
tional fluid is withdrawn, and usually the massing solids begin to roll on the surface owing to the
residual kinetic energy. This action compacts the solids very slightly.  On the final slope of the
screen, the solids tend to hesitate for simple drainage action, but are always moved off the flat sur-
face by displacement with oncoming material.  The effluent is aerated as it passes through the screen
in ultrathin ribbons completely exposed to a natural or controlled atmosphere.

     Unique Features.  The arrangement of transverse wires with unique singular curves in the sense
of flow provides a relatively nonclogging surface for dewatering or screening.  The screens are made
precisely in No. 316 stainless steel and are extremely rugged. Harder, wear-resisting stainless alloys
also may be used for special purposes.

     Openings of 0.010 to 0.060 inch meet normal screening needs. The essential features of the
Hydrasieve are covered in U.S. Letters Patents No. 3,452,876 and No. 3,751,555.  Other U.S. patents
are pending. Patents are also issued and pending in foreign countries.  Figure III-4 shows a diagram
of one Hydrasieve model.

     Use in Meat-Processing Industry Installations.  A broad range of use for Hydrasieve screens has
been developed for meat processors and related operations, including the feed lots and stockyards
as well as the tanning and hide-processing industries. In these fields of service the Hydrasieve may
be modified to provide a "waterfall" (patent applied for) feed concept that can cope more effectively
with high loadings of fat or grease in the slurry  being screened. This development resulted from
research work done on commercial equipment by the Institute of Leather Technology, Milwaukee,
Wis., and has been used widely by the processors of animal hides.

    Paunch manure—the residue from cattle stomachs—consists of fluids plus straw, corn, and
minor miscellaneous solids. The Hydrasieve is an excellent device for screening this slurry, and
usually a 0.040-inch opening screen is used. The solids are separated readily from the carrying
stream, and a 72-inch Hydrasieve normally will handle a flow of 600 gal/min.  Solids are usually
above 5 percent.

     Hog stomach contents consist essentially of whole and split corn, with some hair and the
possibility of fat.  Usually, a 0.040-inch opening screen is employed, and flow rates of about 500
gal/min are obtained on a 72-inch-wide unit.

     Hog-hair recovery is the operation in hog processing in which the animals are scalded and
dehaired in a beater-scraper type of machine. Material coming from this operation is hair and scurf,
a dandruff-type flake.  Also present in this operation is foam, which is self-generating because of
the gelatin that is cooked out of the skins.

     Seventy-two-inch units with 0.020-inch openings are presently in use on the hog-hair recovery
application. Flow is 400-500 gal/min, with loads to 1,000 gal/min when the scalding tub is
dumped. Some problems existed in the operation due to foaming, but these are solved with proper
cold water sprays over the screen and/or antifoam at 10-20-gal/min concentration ahead of the
screen.
                                             22

-------
to
co
                                                                                                                                   I   O.D (fait USl WTM OMSSt*

                                                                                                                                        TtPt COOPUNS,)
                                                                                                                                                         DIA. -12 HOLES

                                                                                                                                                       EQUALLY  SPHiSO
                                                   Figure 111-4.  Diagram for Model 552-36.  (Courtesy of the Bauer Bros. Co.)

-------
     Hair screening is improved with the stockyard, paunch manure, or stomach contents added to
the flow.

     Ash from smokemakers results when, in smoking sausage and other meat products, sawdust is
burned to produce smoke. The ash is washed from the smokemakers and should be removed before
going into grease recovery systems, as this product is unwanted in the rendering. Hydrasieves offer
a satisfactory means of screening the wash water.

     The normal total waste flow from a packing plant is quite heavy with respect to flow, solids,
and fat. Normally, when a packer screens his total flow it is a safety measure used as primary
settling, ahead of additional treatment, such as pressurized air flotation. The material from the
screen may be rendered.

     At present a 72-inch unit with 0.040-inch screen operates on total waste flow of 500-700
gal/min.  Sprays are being used and the application is quite successful.

     A typical operation on a waste stream from an  operation where cattle, hogs, and sheep were
processed is indicated by the test data for a No. 552-2, 72-inch by 54-inch Hydrasieve with 0.040
Marvel' screen, as follows:

     • Flow rate, 550 gal/min

     • Solids removed, 10,000 Ib/day (dry)

     • Solids passed, 6,076 Ib/day (dry)

     • Effluent solids (80 minus 30 mesh), 920 ppm

     • Solids removal, 62.5 percent

     Solids are removed from stickwater, which is product water and condensation water evolved
in the process of wet or steam rendering of lard and tallow. Normally, stickwater is evaporated
to produce a high-protein feed additive.  Solids in stickwater are coarse and fibrous in inedible
rendering, and soft and stringy in edible renderings.  Normally, stickwater is hot (130°-160° F) as
it goes over the screen, eliminating grease blinding.

     Expeller grease solids removal is  performed after meat scraps are rendered in melters. Grease
is drained from the solids. The solids then are pressed in screw presses, and the additional grease is
expelled. This grease contains solids that normally are settled out before the grease is filtered. This
grease is sent over a 0.020-inch test screen, and solids are removed to the extent that settling can
be eliminated. Flow  is low, but separation is also slow. About 5-10 gal/min can be sent overman
18-inch unit with 0.020-inch screen, with adequate results.  Modifications need to be made so that
the  flow will start at  the overflow weir, rather than in a headbox.

     In hide processing, green (untreated) hides are delivered from the meat packer and are either
processed immediately or cured in brine.  The first process is to wash the hide in a drum washer,
where manure and dirt are removed.  Some hair and manure balls are also removed and sent to the
sewer. The Hydrasieve is used here to permit recycling of the wash water and for preliminary solids
removal. A 72-inch unit with 0.060-inch screen permitted one processor to reduce his flow from
this operation by at least half.  Seventy-two-inch units are handling 700 gal/min effectively.

     A fleshing machine is then used to remove tissue  particles and tails.  Handling this flow, due
to its high fat content (5-14 percent), may be done with a Hydrasieve with the waterfall adapter and
periodic cleaning.
                                             24

-------
      Table 111-1 .—Typical design information for stockyard effluent based on use of 0.040-inch slot opening
Hydrasieve
No. 552-18"
No. 552-36"
No. 552-48"
No. 552-60"
No. 552-72"
No. 552-72-2
No. 552-72-4
No. 552-72-6
No. 552-72-8
No. 552-72-10
Overall dimensions, feet
Width
2
3.5
4.5
5.5
6.5
7
14
21
28
35
Depth
3.5
4
5
5
5
9.5
9.5
9.5
9.5
9.5
Height
5
5
7
7
7
7.3
7.3
7.3
7.3
7.3
Weight,
pounds
350
550
650
800
1,000
1,800
3,600
5,400
7,200
9,000
Capacity,
gallons
per minute
75
150
300
400
500
1,000
2,000
3,000
4,000
5,000
Price for
estimating,
dollars
2,600
3,200
4,000
5,000
6,000
10,000
20,000
30,000
40,000
50,000
     The hides are cured by saturation in brine solution. The brine is regenerated continuously.
Brine should be screened on a Hydrasieve to insure proper operation by removing the hair and
manure that accumulate in the brine raceway, or merry-go-round. A 0.030-inch screen in a
72-inch unit will handle 450 gal/min of this solution.

     Summary.  Almost every static screen application problem has its own, slightly different, design
parameters to  be met, and in-plant evaluations are sometimes required.  Usually experience can be
relied upon, however, for an adequate background to engineer a new installation. As a guide, table
III-l gives brief specifications suitable for preliminary planning of an installation of effluent screen.


Vibrating Screens

     Vibrating screens have many uses in a meat packing plant. Figure III-l illustrates the various
areas where they can be used in waste conservation.

     This discussion is intended to acquaint the meat packer with the design criteria and the  basic
theory of vibrating screens.

     Vibrating screens are designed to

     • Convey material retained  on the screen surface to uncover the opening, so that the cloth can
       pass the undersize material or liquid.

     • Agitate the bed of material on the screen surface. Agitation and stratification are required
       to open the bed so that the fine particles or liquids can work their way down through the
       large particles and pass the openings.

     • Dislodge particles that stick or wedge in the opening. Particles of nearly the same dimension
       as the  opening will clog.  Motion of the screen must dislodge the particles.

     • Distribute the material in order  to make most efficient use of the entire screening area. The
       motion of the deck should distribute the material over the deck evenly.

     • Retain material before discharge. For high efficiency, sizing, or removing water from the
       solids, it is desirable to retain  the oversize as long as possible.  The material must be moved
                                              25

-------
       faster at the feed end to obtain quick distribution and a shallow bed where the volume is
       greatest. At the discharge end where the volume is least, the rate of travel should be slowed
       to allow the remaining fines or liquids to be removed.

     Vibrating screens are economical. They vary in size from 2 feet by 4 feet to 8 feet by 20 feet,
and are made up of three major parts.

     • The vibrating frame^or, as some may call it, the box—which is either the welded structure
       or the bolted assembly that supports the vibrating mechanism and the screening medium,
       mounted horizontally or declined on isolation springs
       The screening medium—cloth, perforated plate, or panels
     • The vibrating mechanism—the heart of the vibrating screen—which imparts the motion into
       the vibrating frame

     The effectiveness of a vibrating screen depends on a rapid motion.  Vibrating screens operate
between 900 and 1,800 rpm; the motion can either be circular or straight line, varying from 1/32-
to 1/2-inch total travel.  The speed and motion are selected by the screen manufacturer for the
particular application.

     The vibrating screen is driven by a shaft turning in a pair of bearings. The shaft carries un-
balanced weights, either machined into or keyed to the shaft. This assembly is normally driven by
a V-belt drive.

     When the unbalanced weights are rotated the screen follows the weights through a path.  When
a vibrator is placed on the top of the  box, a slight rocking action will take place, resulting in elliptical
motion with the ellipse leaning toward the vibrator. This motion tends to move the material away
from the feed and retard it at the discharge end. The screen box is mounted on springs to keep
vibration from being transmitted to the supports.

     On most vibrating screens the cloth is pulled tightly across longitudinal steel members equipped
with rubber caps. The cloth may be changed easily by loosening the tension bolts and sliding the
screen cloth out at either end.

     Of prime importance in the selection of a proper vibrating screen is the application of the proper
cloth.  The capacities on liquid vibrating screens are based on the percent open area of the cloth.
With this factor in mind, cloth should be selected with the proper combination of strength of wire
and percent of open area.  If the waste solids to be handled are heavy and abrasive, wire of a greater
thickness and diameter should be used to insure long life.  If the material is light or sticky in nature,
however, the durability of the screening surface may be the smallest consideration. In such a case,
a light wire may be necessary to provide an increased percent of open area.

     Screen cloth is woven in a variety of materials, such as black steel, spring steel,  all types of
stainless steel, Monel, and brass wire. Normally, on liquid waste applications, a type No. 304 stain-
less steel wire is used.  When conditions require other types of metal, however, special wire cloths
can be supplied.

     In the discussion of various installations, the term "mesh" will be used frequently to designate
the opening.  Where mesh is referred to as a number, the reference is to the number of openings to
the linear inch.  The mesh is counted by starting from the center of one wire and counting the num-
ber of openings to a 1-inch distance.  If the count does not work out to an even number, the frac-
tional part of the opening should be specified.
                                             26

-------
                           Figure 111-5. NRM-148 liquid dewatering screen.

     The NRM (fig. III-5) is used in liquid separation extensively; the 4-foot by 8-foot unit costs
slightly more than $3,000, with feed flume and tank in black steel. Prices vary with feeding arrange-
ments, surface sprays (if any), and other details, such as special metals and coatings.


Other Solids Removal Systems

     Screening Devices. Vibrating, rotary, and static screens are the most popular screens for sepa-
rating solids from meat packing plant wastewaters.

     One type of barrel or rotary screen (fig. III-6(a)), driven by external rollers, receives the waste-
water at one open end  and discharges the solids at the other open end.  The liquid passes outward
through the screen, usually stainless steel screen cloth or perforated metal, to a receiving box and
effluent sewer mounted below the screen. Usually the screen is sprayed continuously by means of
a line of external spray nozzles, and is inclined toward the solids exit end.  This type is popular as
an offal screen but has not been used to any great extent in secondary polishing—that is, in removing
solids from waste streams containing low solids concentrations. A screen of this type has been
developed for recycle of hide-brining waters.

     Another rotary screen commonly used in the meat industry (figs. III-6(b) and III-6(c)) is
driven by an external pinion gear. The raw flow is discharged into the interior of the screen below
center, and solids are removed in a trough and screw conveyor  mounted lengthwise at the centerline
of the barrel. The liquid exits outward through the screen into a box in which the screen is partially
submerged.  The screen is usually 40 X 40 mesh, with 1/64-inch openings. Perforated lift paddles
                                             27

-------
                                                          /—filtering mm -14
                                                            sections around
                                                                channel iron ho&nq wu
                                                                ftiesA onto square oar

                                                                  SfruChjfOl rod
                                                                        driving pnon
                                                                     .—rsctrving ton*
                       CROSS-SECTION Of SEWAGE SCREEN SHOWING  CONSTmjCTlON a OPERATION

 Figure  111-6, Rotary screens for wastewater  processing: (a)  rotary screen driven by  external rollers;
     (b)  rotary  screen driven by external  pinion  gear; (c)  cross section of rotary screen driven by
                                              pinion gear.

mounted  lengthwise  on  the  inside surface  of  the screen  assist in  lifting  the solids to the
conveyor trough.  This type is also generally sprayed externally to reduce blinding.  Grease
clogging can be reduced by coating the wire cloth with Teflon. Solids removals up to 82 per-
cent are reported.
                                                  28

-------
                Figure 111-7,  Influx and discharge from spring-mounted motor-driven screen.

     Several other types of mechanical screens have had some application in this field.

     One is a rotating disk that is submerged partially in the wastewater flow. As it rotates, parti-
cles partially adhere and are scalped off above the flow. The screen disk is placed vertically or at
a slight angle.  Some problems arise in maintaining the seal between the rotating disk and the
flowthrough box or sewer.

     Another type is a circular spring-mounted horizontal screen, driven by a motor located under
the screen and equipped with variable eccentric weights.  As the motor rotates, the eccentric
weights impart multiplaned vibrations to the spring-mounted screen.  These units are normally
centrally fed at the top, the liquid discharging through the screen to a pan above the motor and
the sludge discharging from a port at the periphery (see fig. III-7). Pilot units (18 inches diameter)
are available on loan. These screens are used in a number of meat packing plants, principally for
paunch manure removal, for removing solids from the entire manure sewer flow, and for
removing solids from the main sewer leaving the plant. Mesh sizes range from 10 mesh for paunch
manure to 80 mesh for the main plant sewer. One plant uses three 48-inch-diameter separators
with 80-mesh screening to handle a total main plant flow of 800 to 1,100 gal/min.

     A horizontal rotary slowly revolving screen has been developed using wedge bars and the
Coanda effect  (as in the static screen described earlier), but with the wastewater flowing vertically
downward through the screen. Some advantages claimed for rotary design are that the screen is
cleaned in its rotation by means of a doctor blade, that it can be rinsed with a stationary spray
system, and that the vertical downward flow helps backwash the screen as it flows through into
the receiving box under the screen drum. Several meat packing applications are reported, but no
operating data are available to date.

     There are many other ingenious mechanical screens. Some, such as a vertical spinning drum,
successfully have screened meat waste solids. Other screen systems have been tested and are in
limited use.  Under the impetus of need to improve effluents, testing such devices may  be
accelerated.

     Centrifuges.  Centrifuges have found use in processing meat packing wastewater, principally
in improving the quality and concentration of grease from grease recovery catch basins and dis-
solved air flotation.

     At one plant, tallow recovery from a catch basin was enhanced by running the skimmings
through two centrifuges.  At this plant, each centrifuge is of the three-stage type (having separate
                                             29

-------
streams of oil, liquid, and solids), has a capacity of 55 gal/min, is driven by a 25-hp motor, and cost
$36,000 plus about $4,000 for installation. The yield amounts to 80 percent of the recoverable
tallow, with 0.92 percent moisture and a color of 13 to 15.  The temperature is raised to 180° F
and is discharged through an 80-mesh, eccentric-weigh ted-type 60-inch circular vibrating screen,
then heated to 195° F and centrifuged.  The fat is classified as inedible fancy bleachable tallow and
brings top market prices.  Flow rate is about 30,000 to 40,000 gal/day, and recovered fats run
about 5,000 Ib/day.

     One system of blood concentration incorporates a centrifuge to separate the water after
coagulation, using a chemical aid. The centrifuge is reported to remove about 80 percent of the
water.  The coagulated blood is then dried. This system, however, still produces BOD in the effluent.
Drying of whole blood is better for waste conservation.

     First cost and power requirements  tend to limit the use of centrifuges for waste solids recovery.
As requirements for effluent quality  become more stringent, however, the centrifuge may be used
more frequently to remove residual grease and fine solids from waste streams.


     GREASE AND SUSPENDED SOLIDS SEPARATION  BY GRAVITY AND FLOTATION

General

     The catch basin for the separation  of grease and solids from meat packing wastewaters was
developed originally to recover marketable grease.  Because the primary object was grease recovery,
all improvements were centered on skimming. Many catch basins were not equipped with auto-
matic bottom-sludge-removal equipment.  These  basins could often be drained completely to the
sewer, and were sludged out weekly or at frequencies such that septic conditions would not cause
the sludge to rise. Rising sludge was  undesirable  because it could affect the color and reduce the
market value of the grease.

     In the past 20 years, with waste treatment gradually becoming an added economic incentive,
catch basin design has been improved in the solids removal area as  well.  In fact, the low market
value of inedible grease and tallow has reduced concern about quality of the skimmings, and now
the concern is shifting toward overall effluent-quality improvement.

     As might be expected, the combinations of  screening, catch basins, and dissolved air flotation
in pretreatment vary widely. For example, the Beardstown, 111., plant of Oscar Mayer &  Co. dis-
charges the grease sewer to a flotation tank with  30-minute detention at 30 percent recycle (no
chemicals), and the manure-carrying  (nongrease)  sewer to a 3-foot by 8-foot, 4-mesh vibrating
screen followed by a gravity basin with 50-minute detention prior  to lagoon treatment.  Overall
operating results show 49 percent BOD removal,  66 percent suspended solids removal, and 76
percent grease removal.7

     Other pretreatment systems  start with screening the individual waste streams followed by a
gravity catch basin, and then may be followed by a dissolved air flotation unit.

     Gravity grease recovery systems will remove 20-30 percent of the BOD, 40-50 percent of
the suspended solids, and 50-60 percent of the grease (hexane solubles).

     General removals for dissolved air flotation  systems without chemical treatment are about
30-35 percent in BOD, about 60 percent in suspended solids, and 80 percent (some as high as 90
percent) in grease (hexane solubles).  Combinations of gravity catch basins (about 25-30  minutes
detention) followed by dissolved  air  flotation produce somewhat better results, because the catch
                                            30

-------
basin removes the larger solids and thereby reduces the requirements imposed upon the flotation
unit (see discussion of "Dissolved Air Flotation").

     Chemical treatment will improve recovery when installed directly ahead of dissolved air
flotation systems.  Chemical treatment also can improve gravity separation of greases and solids,
but as much as 20 minutes of flocculation may be necessary to effect significant improvements.

     The use of chemicals to enhance coagulation and flotation varies widely.  Generally, flotation
is accomplished without chemicals, unless effluent quality must be improved.  Alum, as a coagu-
lant with or without a polymer, is used but tends to cause an emulsion problem in the cook tank.
Ferric chloride, with or without a polymer, is also used; however, U.S. Department of Agriculture
limitations on iron content in feeds should be checked before selecting this coagulant if significant
amounts are to be used, and if the end product will be a feed ingredient.  As knowledge of poly-
mers improves and their use becomes more general, proper polymers at proper pH and under con-
trolled mixing conditions may be effective alone, and thus may eliminate the problems incident
to iron and alum treatment.  Zinc chloride has had some success as a coagulant and may be effective
in combination with a polymer.  The proper pH—an important factor—should be determined by
coagulation tests.

     Manure-carrying sewers commonly are pretreated by means of screens, gravity basins, and
sometimes dissolved air flotation before discharge to the public sewers. If the wastewaters are
treated in  a separate system for discharge to a watercourse, the type of biological waste treatment
may not require the degree of solids removal necessary for discharge to the public sewer.

     Simple settling tanks are useful for stockpen flows.  They generally consist of shallow con-
crete trenches, about 3 feet deep, designed for cleaning with a bulldozer.8 A simple baffle at the
outlet end prevents escape of floatables.  One head of cattle in a feed lot will discharge 10 to 15
times as much BOD as one person in the same period of time.


Gravity Grease Separation and Suspended Solids Recovery in Rectangular Basins

     Design Elements. Engineers are sharply divided as to the merits of rectangular versus circular
separators for various purposes.  Many prefer rectangular to circular gravity grease recovery tanks
because they  believe that, in the circular tank, the grease loses its cohesiveness as the flow proceeds
outward in a radial direction, with the scum covering an ever-increasing surface area, and thereby
becomes thinner as it approaches the scum-removal device at  the outer periphery.  Others claim
that the gradually reducing velocity of the flow as it moves radially  outward  improves grease sepa-
ration as well as solids separation (a majority of engineers prefer circular tanks for settling floccu-
lent solids). It is safe to  say, however, that the majority favor rectangular basins for gravity recovery
of grease.  Accordingly, this section will concentrate on  this type. In dissolved air flotation systems
(discussed later) the two factions are about even. In clarification following biological treatment
systems, the circular clarifiers have a decided majority.

     Following are size criteria based largely on experience.  If individual State standards  normally
applied to clarifier design are imposed on the meat packer for catch basin design, the regulations
of course must be followed.

     Rate of flow is the most important criterion for design of a gravity unit. About 30 to 40
minutes' detention time at 1-hour peak flow is a common sizing factor. A shallow basin, 5 to 6 feet
liquid depth, generally is preferred. This depth produces about 1 gal/min per square foot area.
The daily  flow has little relationship to the design of grease recovery systems.
                                             31

-------
     Length-to-width ratio should be at least 3 to 1. Maximum widths are about 20 feet, but
heavy sludges may cause an excessive stress on the scrapers at that width. Widths to 12 feet are
safe. Beyond this width stresses should be checked, particularly if the system is operated
intermittently.

     Temperature variations can develop nonuniform density currents, reducing the efficiency of
grease and solids separation. Overnight icing can occur in northern climates. Accordingly, pro-
tection against wide variations in temperature should be considered.

     The design of inlet and outlet arrangements, as well as scum removal, will materially affect
the basin efficiency.

     The bottom (invert) of the influent sewer should be above the liquid level in the basin.  The
inlet, however, can enter the basin below the liquid surface. Properly baffled, multiple inlets will
reduce inlet velocities but can cause backup in the influent sewer or in an upstream receiving box
where scum can collect. Design of such a receiving box to overflow at high-flow periods could
prevent scum accumulation in the box. Surface discharge into the basin, on the other hand, can
develop velocity currents in the basin. However, multiple surface inlet openings with adjustable
baffles will reduce entrance velocities, permit manual adjustments of distribution of the flow across
the basin width, and prevent upstream scum accumulations.

     The effluent should  be conducted over a weir extending the full width of the basin.  Weir
overflow rates should not exceed 1,500 gallons per lineal foot per hour of maximum flow. A weir
trough at the outlet will provide double weir length if necessary.

     Scum  removal equipment is available in several styles.

     The slotted "swing-pipe" scum trough (see fig. III-8) is popular in rectangular municipal
clarifiers. In operation, it is periodically rotated manually to a point where the slot meets the
liquid level, allowing scum to enter the pipe and flow out one end to a receiving box. It is inadequate
generally for the quantities of scum encountered in treating meat packing wastewaters.

     A powered helical scum collector (fig. III-9) that mechanizes scum pickup is also available.
Its dewatering efficiency and its capacity do not usually satisfy the requirements for scum removal
in meat packing wastewater systems, but it is a slight improvement over the swing pipe.

     A more positive pickup, but using the same four-sprocket sludge and scum scraper system,
consists of a scum trough and "beach" with a short flight-type skimmer (fig. 111-10).  The skimmings
trough extends the full width of the basin and should be sloped to discharge to a receiving box where
the grease can be decanted from the residual water. In large installations, a screw conveyor in the
trough will be useful. In cold climates, the shaft of the screw can be hollow and can be connected
to a steam line to keep  the scum from freezing in the trough.  The scum trough should be several
inches above the liquid level. The metal beach provided on the upstream side  for scum pickup
permits some dewatering  of the scum on that part of the beach above the water level.  A short
baffle fastened to the underside of the trough and extending downward will reduce scum  loss
caused by effluent  flow moving toward the effluent weir downstream from the trough.

     All of the foregoing  skimming arrangements permit some grease to escape to the effluent be-
cause the grease adheres to the flights as they pass downward under the skimming device. To
eliminate this defect, two sets of scraper flights can be provided, as shown in figure III-ll. In this
system, the sludge is moved independently of scum removal by a three-sprocket collector. A
separate two-sprocket scraper system,  operating above the liquid level, moves the scum toward the
scum trough and up the beach into the trough. In this arrangement, septic action can be prevented
                                             32

-------
     u_
cte
J> IF




	
S-A 	
\ /* =
~.\/
tffyvfe*


















	 T 	 ^fl






7 	 ^
1:1



t Ja

\




E=,










1 t
V.
^
,<





„ 4
- - ~"
c





V.
^





	 *^_
^ *












J-s
	
^

Li 	
co
co
                             Figure 111-8. Four-sprocket collector with scum pipe for grease recovery.  (Courtesy of the Link-Belt Company.)

-------
CO
*>.
                          c
                          ^
                          re
                          tO
                          I
                          re
                          c
                          I
                          3


                          (D
                          O
                          O
                          •
                          O
                          CO

                          2.
                          ?
                          3

-------
                                                                                  SCUM TMMX mitt IK
                                                                                  mm iu.it • HIM
                                                                                  (w OF torn TINM
                                                                                   •!• MTU UMl
                                                                                   n HH
      Figure 111-10. Four-sprocket collector with flight-type skimmer. (Courtesy of the Link-Belt Company.)

by operating the bottom scrapers continuously.  The scum scrapers also can be operated separately
on a timer to hold the scum and develop a cohesive dense layer, thereby reducing the liquid content
of the skimmings. Normally, about 70 percent of the scum picked up is water. The two-flight sys-
tem can reduce the water content about 15 to 20 percent.

     A new pork plant using this type of arrangement has a production day's flow of 620,000
gal/day and 860 gal/min in a maximum hour.  This plant is large, and has  complete smoking and
sausage manufacturing. Pretreatment consists of a gravity basin (equipped for adding dissolved air
flotation when necessary) designed for 28 minutes' detention (12 feet wide, 45 feet long, and 6 feet
side-water depth). Estimated raw waste concentrations are 450 mg/1 BOD, 400 mg/1 suspended
solids, and 350 mg/1 grease. No raw waste operating data are available to  date, but effluent samples
taken on January 17,1973, show BOD 250 mg/1, suspended solids 70 mg/1, and grease 26 mg/1.
Sanitary wastes are included in these figure*-.

     Scraper mechanism for sludge removal may scrape the sludge to one  or several submerged
hoppers, generally at the inlet end of the basin. The need for several hoppers arises from two de-
sign limitations.  First, the side slopes for the sludge hoppers should be at least 60° with the hori-
zontal. Second, the flat bottom of the hopper should be no  greater than  2 feet by 2 feet in size.

     In one innovation that eliminates the hoppers and sludge pumps, the effluent end of the
basin is built in an incline and the sludge is scraped up the incline into a receiving trough at the
top.  The sludge is partially dewatered on that portion  of the incline that  extends above the liquid
level. The incline can be as long as necessary to accomplish the desired dewatering before the
sludge discharges into the trough.  A screw conveyor in the sludge trough  is an added convenience
to carry the sludge to a truck or receiving box alongside the basin. The effluent weirs and scum
removal trough are, of course, upstream from the incline.
                                             35

-------
CO
OS
                 Figure 111-11. Three-sprocket collector with flight skimmer full length and cross screw conveyor. (Courtesy of the Link-Belt Company).

-------
     Basin Arrangement and Materials of Construction. Usually two identical catch basins, with a
common wall, are desirable to permit one to operate whenever the other is down for maintenance
or repair.  Note that the "Design Example" (following) is based on this arrangement.

     Concrete tanks have the inherent advantages of lower overall maintenance and more permanence
of structure.  Some owners, however, prefer to be able to modify their operation for future expansion
or alterations, or even for relocation.

     All-steel tanks have the advantage of being semiportable, more easily field erected, and more
easily modified than concrete tanks. The all-steel tanks, however, require additional maintenance as
a result of wear in areas of abrasion.

     A tank equipped with all-steel walls and concrete bottom is probably the best compromise be-
tween the all-steel tank and  the all-concrete tank. The advantages are the same as for steel. The all-
steel tank, however, requires a footing underneath the supporting members; with the steel-wall tank
the concrete bottom forms the floor and supporting footings for the tank.

     Design Example.  Given a peak-hour flow of 1,300 gal/min, design a rectangular catch basin.

     • At a selected 40-minute detention, the volume = 52,000 gallons = 6,950 ft3.

     • Select 6 feet average water depth; area = 1,160 ft2.

     • Select two basins, with a common wall, each 10 feet wide, 58 feet long, and  6 feet average
       water depth.

     Cost Estimates for Design Example.  All costs are for  two basins, with a common wall between
them.  Table III-2 gives cost estimates that are order-of-magnitude prices, and thus should not be
used for other than rough approximations.  In each particular application, equipment prices and
construction costs should be developed for the area where  the plant is located and for the specific
situation.

                  Table 111-Z—Cost estimates for design example, rectangular catch basin
                                            [Dollars)
Basin
Concrete
Steel 	
Steel with concrete floor

Cost installed
25,000
29,000
32,000
Equipment
Type1
I
II
III
I
II
HI
1
II
III
Base cost
12,500
23,000
32,400
12,500
23,000
32,500
12,500
23,000
32,500
Installation cost
3,000
3,500
5,600
3,000
3,500
5,500
3,000
3,500
5,500
Total
40,500
51,500
63,000
44,500
55,500
67,000
47,500
58,500
70,000
      Type I, four-sprocket collector with rotatable scum pipe; type II, four-sprocket collector with short flight skimmer without
screw conveyor in trough (slightly less with helical scum skimmer); type III, three-sprocket sludge collector with full-length, separate,
two-sprocket scum-scraper system, and with screw conveyor in trough.
                                              37

-------
     Maintenance and Operation. Most gravity grease recovery units use no chemicals, flocculants,
or polymers to achieve the grease separation.  There is no requirement, therefore, for design or main-
tenance of a chemical-feeding system. The gravity grease recovery unit is quite simple in construc-
tion and operation, alleviating the need for sophisticated or highly trained operators.

     In gravity grease recovery and separation, as with any system of wastewater treatment, the
overall system must be considered in addition to the individual elements. Particular attention should
be given to maintaining low turbulence in the flow, and minimizing frequency of pumping.

     Each gravity grease recovery system requires a certain amount of housekeeping. After being in
operation for a few months, the equipment becomes coated with grease.  It is difficult, if not im-
possible, to maintain the equipment when the parts are not visible.  Hence, there is a need for scrap-
ing, scrubbing, steam cleaning, and in some cases high-pressure hosing, to assist the people responsi-
ble for maintenance in keeping the units operational. Cleanliness also helps in the control of odors
and elimination of odor-producing bacteria.

     Day-to-day observation and periodic checking of alinement, grease levels in speed reducers, and
greasing of bearings are natural requirements for mechanical maintenance of any wastewater equip-
ment.  Eventually the chains will wear and require replacement. This equipment has a wear life pro-
portional to the hours of use; hence,  operation on timers is recommended.  A high percentage of grit
in the wastewater may accelerate the wearing of the components, because the grease will tend to hold
the grit into the wearing part of the unit, acting as a lapping compound and accelerating the wear.

     Pilot Plants. The use of pilot plants for grease recovery and other wastewater treatment design
cannot be overemphasized. The most important information obtained from pilot plant studies is
that the plant can be operated with a relative flow rate and waste characteristics representative of
those for which the ultimate plant will be designed.  One of the most frequent errors in the use of
pilot plants for design purposes is the application of pilot plant data from one meat packing plant
to another with different flow pattern, production processes, and production equipment.

     Most major manufacturers have pilot plant equipment available on rental terms.


Dissolved Air Flotation

     Dissolved air flotation is a waste-treatment process in which oil, grease, and other suspended
matter are removed from a waste stream.  This treatment process has been in use for over 15 years,
and has been most successful in removing oil from waste streams. Its principal early use was, as it
still is, the removal of oil from petroleum refinery wastewaters.  Another natural area for applica-
tion of this treatment system has been the removal of contaminants from food-processing plant
waste streams. One of the very first applications of this treatment system was for meat processing.

     Basically, dissolved air flotation is a process for removing suspended matter from wastewater
that uses minute air bubbles, which upon  attachment to a discrete particle reduce the effective
specific gravity of the aggregate particle to less than  that of water. Reduction  of the specific gravity
for the aggregate particle causes separation from the carrying liquid in an upward direction. As
figure 111-12 suggests, the particle to be removed may have a natural tendency either to rise or to
settle.  Attachment of the air bubble to the particle induces a vertical rate of rise noted as VT.

     Figure 111-13 illustrates the basic design considerations of the flotation unit.  The measure-
ment of the parameter VT will be discussed later. Since the waste flow must pass through a treat-
ment unit, the particle to be removed will have a horizontal velocity. Certain criteria have been
established for limits of the parameter VH, which sets the width and depth of the treatment unit.
                                             38

-------
                                     Figure 111-12. Separation of
                                     particle from wastewater by
                                       dissolved air flotation.
                                      (Vf = vertical rate of rise.)
                                            V.
                                              H
                Figure 111-13. Basic design concept of flotation unit. (VT = vertical rate of rise;
                          VH = horizontal velocity; L = length of treatment unit.)

Therefore, as figure 111-13 suggests, the effective length of the treatment unit is directly propor-
tional to the horizontal velocity and depth and inversely proportional to the vertical rate of rise of
the particle to be removed.

     The mechanics of operation for a dissolved air flotation unit are illustrated in figure 111-14. It
can be noted that a portion of the clarified effluent is pressurized by a recycle pump.  This recy-
cled flow is pumped to a pressure tank into which air is injected.  In the pressure tank at approxi-
mately 40 psig, the recycle flow is almost completely saturated with air. The pressurized recycle
flow, containing the dissolved air, leaves the air saturation tank and flows through a pressure reduc-
tion valve.
                                               39

-------
     Figure 111-14. Dissolved air flotation unit:  mechanism of operation.
RECYCLE
                                Pressure
                                tank
Pump
TOTAL
PARTIAL
                  Figure 111-15.  Injecting air bubbles into
                  the waste stream: recycling, total pres-
                   surization, and partial pressurization.
                                   40

-------
     A 40-psig pressure drop occurs at the pressure reduction valve and causes the pressurized flow
stream to relinquish its dissolved air in the form of tiny air bubbles. This air-charged recycle flow
is then blended with the raw process flow to effect attachment of the air bubbles to the oil and
other suspended solids to be removed. The combined flow stream (raw flow plus recycle flow con-
taining the air bubbles) is mixed and uniformly distributed over the cross section of the basin.

     As the incoming  flow travels to the effluent end of the basin, separation of the oil and solids
from the associated liquid occurs. Solids accumulate at the water surface and form an oily sludge
blanket.  Clarified liquid flows over the effluent weir and into a wet well. From the effluent wet
well, a portion of the effluent is recirculated.  The remainder of the effluent is removed from the
basin for subsequent treatment or discharge. The floated scum blanket of separated solids can be
removed from the basin by skimmer flights traveling between two endless strands of chain. Since
the influent stream may also contain small amounts of heavy solids, such as grit, which are not
amenable to flotation, provision must also be made for solids removal from the bottom of the unit.

     The foregoing discussion illustrates the recycle method of injecting the air bubbles into the
waste stream. Figure 111-15 shows all three methods of dissolved air injection currently used.  Total
pressurization, as the name implies, occurs where the total waste flow is pressurized before entering
the treatment unit.  Partial pressurization is a method whereby a portion of the waste flow is pres-
surized and mixed with the remaining raw flow before entering the treatment unit.

     To obtain  optimum treatment with some wastes, it has been necessary to use chemical pre-
treatment before dissolved air flotation.  The necessity for use of chemical conditioning is normally
associated with a high degree of emulsification of the oil or grease matter in waste stream flow. It
is, therefore, a requirement to break the emulsion and form a floe to absorb the oil or grease.  It has
been shown (fig. 111-16) that increasing the particle size increases the rate of separation. Floccula-
tion as a means of promoting particle growth preceding flotation contributes to the effectiveness of
the flotation process where chemical conditioning is  used. The points of chemical injection and the
possible use of flocculation associated with the three methods of air injection are shown in figure
111-17.

     The use of steel-package dissolved air flotation units lends itself to application in the meat-
processing industry. This arrangement provides an economical, flexible design that requires minimal
construction cost and  area investment.  Most manufacturers of dissolved air flotation units have a
complete line of steel tank units to meet a wide variety of flow conditions.  Rex Nord  Model No.
9550A (fig. 111-18) would handle a raw waste flow of approximately 800 gal/min. Model No. 8032
handles a raw flow of about 300 gal/min, and  Model  No. 6020 would handle a raw flow of about
200 gal/min.  These raw flow figures were based on a vertical particle rise rate of 0.5 ft/min and a
recycle rate of 33 percent.

     The use of steel-package units lends itself equally  well to those applications requiring flash.
mixing and flocculation as a part of chemical pretreatment.

     In the following discussion, a steel-package Model No. 6020 with flash mix and flocculation
compartments has been used to illustrate the costs associated with this type of unit. The capital
cost of this unit would be approximately $37,500, which would include the following  equipment:

     • Flash mixer and drive

     • Flocculator and drive

     • Two-shaft surface skimmer and drive

     • Screw conveyor, sludge collector, and  drive


                                             41

-------
Ill
MOi4O
K?
w£ 030
2
0*0



-xs

O<


^
)

K> 0.

,-xt
^

SO 0.

^


BO 0.




TO 0




BO
                  AVERAGE PARTICLE  SIZE
                            (mm)
Figure 111-16.  Effect of average particle size on rate of rise:  100
       ppm lime; 20 ppm bentonite; 20 percent recycle.
   TOTAL
I                   PRESSURE
                   RETENTION
    FLOCCULATING     TAIgK
       AGENT
    OF REQUIRED)
                                                 CLARIFIED
                                                 EFFLUENT
   PARTIAL
                                           OILYKUM
    WASTE
    PLOCCULATINC
       AGENT
    (IPMEQUREO)
   RECYCLE
   WASTE
FUXCUUkTION
  CHAMBER
(IF REQUIRED)
                                        FLOTATION
                                        CHAMBER
                     AIR
    1
CLARIFIED.

EFFLUENT
                        PMS3URE
                       RETINTION
                         TANK
   FLOCCULATING
      AGENT  v
   (IP REQUIRED)
     Figure 111-17.  Points of chemical injection and use of
    flocculation associated with total and partial pressuriza-
                     tion and recycling.
                            42

-------
                                                                                                                THROTTLING VMVE
f
                 *••
                 CO
                           PRESSURE
                           REGULATING
 PLUG \W_VF. WHEN
 AUTOMATIC  CONTROLS
 ARE USED
                   PRESSURE TANK
                                                                                       FLOW METER
                             INLET ARRANGEMENT
                             FOR  TANK 6-0'TO 9-6"WIDE
                                  PLAtL
                          SKIMMER
                          DRIVE
ja
                   ("PUMP SELECTED ON BASIS OF MAXIMUM
m- - ~     ~  -, 'S  REQURED PRESSURIZED FLOW DELIVERED ID
PRESSURIZING  PUMP ^PRESSURE TANK S 40 BS.I.
                                                                                                                              SEE PRESSURE  TANK SIZE
                                4" DIA PIPE
                                                                                                            SEE TABLE FOR     /SCREW CONVEYOR
                                                                                                            NUMBER OF LEGS    \ DRIVE UNIT
                                                       Figure 111-18.  Steel tank with skimmer and sludge-removal facilities. (Courtesy of Rex Nord, Inc.)

-------
                       Table I \\-3.-Operating horsepower for Rex Nord Model 6020
Item
Flash mixer 	 ...
Flocculator 	
Skimmer
Bottom screw .
Recycle pump . . . . . . .
Compressor 	
Total . ....

Horsepower
0 5
5
5
5
7 5
1 5
11 0

                         Note.—Based on a 10-hour-day, 5-day-week operation, yearly operating
                    costs equal: $214, at 1 cent per kW-h;and $321, at 1.5 cents per kW-h.

     • Complete steel tank

     • Pressure tank and associated air control system

     • Recycle pump

     • Compressor

     • Recycle piping

     Table III-3 lists the operating horsepower included in the unit described. Based on a 10-hour-
day, 5-day-week operation, costs of running Model No. 6020 for 52 weeks are shown for electrical
costs at 1 cent per kW-h and 1.5 cent per kW-h.

     To give a full range of capital costs involved with steel-package flotation units, the largest unit,
Model 9550A, would cost approximately $57,000 with the above-listed equipment.  Model 2511,
the smallest unit, would cost approximately $22,000 with the same components.

     Tables III-4 and III-5 list operating results from units treating wastes of a mixed kill of hogs
and cattle and from a ham-packing operation.  Tables III-6 and III-7 show results from bench scale
testing of different types of meat-processing waste  and indicate degrees of treatment obtained in
different methods of treatment.

     In several  of the results, the use of chemicals was necessary to meet treatment objectives.
Table III-4 indicates the use of a cationic polyelectrolyte at a dosage of 0.75 mg/1. Based on a flow
of 1,600 gal/min and a chemical cost of 40 cents per pound, the cost for the chemical for a 12-hour
operation would be a little less than $3 per day.  The cost of a simple polyelectrolyte feed system
would be around $6,000.

     As is the case with most industrial  waste, treatability studies should be conducted to determine
not only the design parameters for a flotation unit, but also to determine whether chemical
treatment is a necessity to meet treatment objectives.

     Pilot dissolved air flotation units are available from most manufacturers for treatability studies.
The rental cost varies, but the normal rate is approximately $500 per month.

     A laboratory bench scale test procedure developed to simulate the dissolved air flotation process
has been used most successfully in the determination of design parameters for an air flotation unit.
                                              44

-------
                       Table 11 \-4.-Plant A operating results, hogs and cattle killing
                                         [Flow, 1,600gal/min)
Sample
Untreated
After gravity settling (25 minutes approximately) . .
After gravity settling followed by dissolved air flotation
treatment, 33-percent pressurized flow:
Type chemical cationic polyelectrolyte A dosage
Type chemical cationic polyelectrolyte B dosage




with chemical
0 75 mg/l
0 75 mg/l . .

Hexane-soluble
grease remaining,
mg/l
3 000
1 200
230
80

Percent
removal

60
180
193

      Percent removal beyond that obtained by gravity settling alone.
                       Table 111-5.—Plant B operating results, ham packing, no killing
                               [Flow, 200-gal/min design, 385-gal/min present]
Sample
Untreated:
Suspended solids
BOD
Hexane-soluble grease 	
After dissolved air flotation, without chemicals, 33-percent pressurized flow:
Suspended solids 	 	 	
BOD .... . . 	
Hexane-soluble grease

Constituent
remaining,
mg/l
350
1 100
600+
300
400
80

Percent
removal



17
64
87

     This flotation test (fig. 111-19) is used to determine the suspended particle rise rate (VT), which
is the most critical design parameter in the design of the flotation unit. The rate is determined by
filling the pressure cell with liquid to simulate closely the recirculation of the unit effluent of pres-
surization in a full size unit; this recycle water should be developed by several previous flotation runs.
This liquid is then injected with air until a pressure of over 40 psi is obtained; the cell then is shaken
vigorously to insure that the air is put into the solution. The pressurized liquid then is introduced
into the waste. The exact amount of pressurized liquid is determined by trial and error for best
results.  As the minute bubbles are released from solution, they attach to the suspended particle and
oil and rise to the surface. After flotation is complete, a sample of the effluent is taken and analyzed.
During the test, observation of the rise rate of the major portion  of the solid material with respect
to time is recorded.  From a graphic plot of these data a rise rate can be calculated.  This rise rate,
along with factors for turbulence and short circuiting, is used in the selection of the basin size neces-
sary to accomplish treatment required.


Other Systems

     Whereas the preceding section was limited to a discussion of rectangular dissolved air flotation
systems, it should be noted that the same  principles are applied to circular-shaped tanks by a number
of equipment manufacturers. These tanks are similar to conventional clarifiers with center baffled
                                               45

-------
                        Table 11 \-6.-Plam C bench scale testing results, hog killing
                                  Sample
Constituent
 remaining,
   mg/1
Percent
removal
Untreated:
     Suspended solids	
     BOD	
     Hexane-soluble grease	
After gravity settling (laboratory time to simulate 30 minutes full scale):
     Suspended solids	
     BOD	
     Hexane-soluble grease	
After gravity settling followed by dissolved air flotation, without chemicals,
   33-percent pressurized recycle flow:
     Suspended solids	
     BOD	
     Hexane-soluble grease	
After gravity settling followed by dissolved air flotation, with chemical treatment,
   dosage 200 mg/l alum and 1 mg/l anionic polyelectrolyte:
     Suspended solids	
     BOD	
     Hexane-soluble grease	
  3,700
  2,800
  3,300

    800
    600
    500
   440
   380
   190
   230
   210
     55
   78
   79
   85
  145
  136
  162
 165
 188
      Percent removal beyond that obtained by gravity settling alone.
                        Table I\\-7.-Plant D bench scale testing results, lamb killing
Sample
Untreated (grab sample) 	 	
After dissolved air flotation, without chemicals, 33-percent pressurized flow . .
After dissolved air flotation, with chemicals, 33-percent pressurized flow,
dosage 0.75 mg/l cationic polyelectrolyte .

Hexane-soluble
grease remaining,
mg/l
2 600
104
76

Percent
removal

96
97

inlet, peripheral weir, bottom sludge removal scrapers, and surface skimmer arms discharging to a
surface scum trough.  The pressurized air recycle arrangements are the same as those used in rectan-
gular tank systems. These circular systems average approximately $1,200 per foot of diameter to
20 feet in diameter, and $1,000 per foot of diameter above 20 feet.  These costs include steel tank
side sheets, sludge and scum removal mechanism, pressurizing pump, air saturation tank, and air
compressor. Installation costs can be estimated at 40 percent of the equipment costs.  Variations
among manufacturers lie in proprietary details such as baffling of the influent, design of the skim-
ming system, design of the effluent trough, and design of the scraper mechanism.

     Figure 111-20 shows suggested systems that are applicable to both circular or rectangular flota-
tion units.  The primary skim tank is a gravity  catch basin and the Sediflotor Clarifier is a proprietary
circular dissolved air flotation system. The systems shown in figure III-20(d and e), with proper
chemical treatment, are claimed to produce 90-percent grease removal and 70-90-percent  BOD and
suspended solids removal. Figure 111-21 illustrates the circular type of flotation system.
                                                46

-------
         Component parts—Rex Flot-Aire Kit
Flot-Aire pressure cell with clarified effluent
       Glass cylinder with raw waste
       Clarified effluent in Flor-Aire pressure cell
                 pressurized to 40 psi
                                                                        Pressurized effluent introduced to raw waste
Figure lli-19.  Laboratory bench scale test to simulate dissolved air flotation process.  (Courtesy of Rex Nord, Inc.)
                                                          47

-------
     Minute air bubbles floating waste material
              to surface of cylinder
 Flotation complete in cylinder
Clarified waste sample being withdrawn from cylinder
Analysis made of clarified waste
       Figure 111-19.  Laboratory bench scale test to simulate dissolved air flotation process.—Continued
                                                         48

-------
A.  Assume that a recirculation ratio of 0. 33/1 is to be tried.

    1.   Place 750 ml of a representative sample of the waste in a one liter
        graduated glass cylinder. (See Figure 3, Data Sheet 315-10. 804. )

    2.   Fill the Float-Treat Pressure Cell approximately three-fourths full
        with liquid.  (See Figure  3, Data Sheet 315-10. 804. )
              (It is desirable that the operation of the Float-Treat
              Pressure  Cell closely  similate the recirculation of
              effluent as used in the  Float-Treat Flotation System.
              The returned effluent (recycle water) may be developed
              by repeated flotation of several different portions of raw
              waste.  After the recycle water has been developed and
              used in the flotation tests,  samples may then be withdrawn
              for chemical analyses. )

    3.   Secure the cover gasket and  cover of the Float-Treat Cell,  making
        certain all the valves are closed.

    4.   Inject air  into the cell until a pressure of 40 psi is attained  and
        maintained during testing.  (See Figure 4,  Data Sheet 315-10. 804. )

    5.   Shake the  cell vigorously for thirty seconds.

    6.   Release 250 ml of the liquid which has been pressurized into the
        graduated  cylinder. (See Figure 5, Data Sheet 315-10.804.)  The
        volume of liquid in the graduated cylinder then totals 1000 ml
        (750 ml raw and 250 ml pressurized).  The ratio of volumes of
        recycle water to the raw waste is termed the recycle ratio.   This
        ratio is expressed in  percent and is termed the recycle rate.  Thus,
        the recycle rate used in this  test is 33%.   The most suitable recycle
        rate can be determined by repeated tests at varying rates of recycle
        and usually is not less than 20% and no more than 50%.  To  facilitate
        the introduction  of the air-charged recycle water to the graduated
        cylinder, a rubber tube may  be connected  to the petcock on  the
        pressure cell.  After clearing the rubber tube of air,  (Allow some
        liquid  to escape  through the tube by opening petcock.  Sufficient
        liquid  should be  removed until it has a milky appearance) the air-
        charged recycle water is introduced through the rubber tube into the
        graduated  cylinder.  The end of tube should be placed near bottom of
        the cylinder.  (See Figure 5,  Data Sheet 315-10.804.)
   Figure 111-19. Laboratory bench scale test to simulate dissolved air flotation process.— Continued
                                    49

-------
     The air bubbles rise through liquid in a manner similar to that in
     the Float-Treat flotation system.

7.   Allow the contents of the graduated cylinder to come to rest and
     observe the flotation. (See Figure 6,  Data Sheet 315-10. 805.)
     Allow sufficient time for the rising solids to come to the surface
     of the liquid.   Usually ten minutes will be sufficient time for the
     flotation to be completed. (See Figure 7,  Data Sheet 315-10. 805.)

8.   After the flotation is completed, a sample of the raw waste and
     treated waste should be taken for analysis. (See Figures 8 and 9,
     Data Sheet 315-10. 805. ) The treated waste should be carefully
     withdrawn from the graduated cylinder either through the use of
     a petcock installed in the side and near the bottom of the cylinder
     or through the use of a siphon inserted in the cylinder. Sufficient
     liquid should be withdrawn to complete the desired analysis,  how-
     ever,  care should be taken to avoid the break up of the skum blanket.

9.   Should chemical flocculation with flotation be desired,  the chemical
     may be added into the raw waste after step "1" is completed, floc-
     culation may be  carried  out, for convenience, in another vessel.
     Care should be taken not to  break up the floe when transferring the
     waste to the cylinder. Enough time for flocculation should be allowed
     before introducing the air-charged recycle water.  Under appropriate
     conditions, a  floe may  be formed  by gentle agitation of the waste
     after the chemical is added.  The procedure described above also
     applies when  chemical  flocculation is used.  When using chemical
     flocculation,  care should be exercised not to break up the floe par-
     ticles in handling  the flocculated waste.

     Because of the peculiarities of some floe  formations, they will break
     up readily upon any excessive agitation after being formed.   This  is
     most readily noticed when a liquid with a preformed floe is transferred
     from the cylinder used in the jar mixing  test to the cylinder used  in
     the flocculation test.  If the floe does break up  and does not re-form
     immediately,  it is suggested that the  transfer to the flotation cell not
     be made and that  flotation be accomplished in the vessel  where the
     floe was formed.   The procedure for running this test are the same.
     However, withdrawing of the clarified liquid, as described in step  "8",
     will probably  be  through  a  siphon.
 Figure 111-19. Laboratory bench scale test to simulate dissolved air flotation process.—Continued
                                  50

-------
In flotation of a particular waste,  it is quite possible that the test using
the recirculation ratio of  0. 33/1 may not yield the best  results.  It
may be that  some other recirculation ratio would  yield the results
needed to work  in with the economy of a final plant  design and effluent
requirements.   Therefore, the tests  described above may be repeated
with other recirculation ratios until the  optimum ratio is obtained.  In
these tests the values shown  in steps  "l" and "6" will be  changed
accordingly.

When running flotation tests in the  Rex Float-Treat demonstration kit,
the observed rate  of  rise of the major  portion of the solid material
should be recorded.  This value can be recorded in terms of inches per
minute and will be used in determining the  full scale plant requirements.

In order to insure the validity of results obtained, care should be taken
that representative samples of waste  are obtained before running tests.
When results have been  obtained, they should  be  recorded on Question-
naire for Design Data  Sheets 315-10.101 and 315-10.102.  These
completed sheets  shovild be returned  to  CHAIN Belt Company.
Figure 111-19. Laboratory bench scale test to simulate dissolved air flotation process.—Concluded.
                                  51

-------
(a)
                                                       Air Saturation Tank
                                             Air
                                          40-60 PSI
Pressurizing
Pump
Sump or Primary
Skim Tank


   5—30 Min Retention Time
                                                                                        E ffluent to Discharge
                                                                                        or Further Treatment
(b)
                                                                                       Effluent to Discharge
                                                                                       or F urther Treatment
  5—30 Min Retention Time
(c)
                 5—30 Min Retention Time
                                                                                            E ff luerrt
                                                                                            to Discharge or
                                                                                            Further Treatment
(d)
                                                      Air Saturation Tank
                                              Air
                                           40-60 PSI"
                                                                           Press Pump
                                                                                     Effluent to Discharge
                                                                                     or Further T reatment
   5—30 Min Retention T ime          5 Min Retention T ime
(e)
                                                                  Air Saturation Tank
                                                           Air
                                                         40-60 PSI '
                                   Treatment Chemicals




Sump or Primary
Skim T ank
  5-30 Min Retention Time
                                                                                       Press Pump
                                                                                     50% Recycle
                                                                                           Effluent to
                                                                                           Discharge or
                                                                                           F urther T reatment
                                               5 Min Retention T ime
   Figure 111-20. Typical flow sheets for meat packing and processing industry.  (Courtesy
                      of Westinghouse Electric Corporation, Infilco Division.)
                                                   52

-------
                                                                  "H" SCUM OUTLET
     WEIR ADJUSTING  NUT
     LADDER
                          MUST BE LEVEL
                      _"   WITHIN ±  1/8"
                                                                                                      D' INFLUENT
                                                                                                      (BY OTHERS)
     *f* EFFLUENT
     GROUT AFTER TANK
     PLATES WELDED
     IN PLACE
            DETAIL Y
                                                                                                        SCUM
                                                                                                        TROUGH
                                                                                          SKIMMER DETAIL
                             -HANDRAIL-PIPE a  ANGLE
      *r* EFFLUENT

      "E" RECYCLE OUTLET
                    DETAIL  Y
                               "G* SLUDGE LINE
                                 (BY OTHERS)
                                                                        \	RECYCLE "E"
                                                                            BY OTHERS
                                                           ELEVATION
A
B
C
0
E
F
TANK DIAMETER
SIDESHEET HEIGHT
SIOESHEET THICKNESS
INFLUENT
RECYCLE
EFFLUENT
G
H
I
J
K
L
SLUDGE BLOWOFF
SCUM OUTLET
SLUDGE SUMP, WIDTH
SLUDGE SUMP. DEPTH
NUMBER OF SKIMMERS
DRIVE HORSEPOWER
Figure 111-21.  Infilco Sediflotor Clarifier.  (Courtesy of Westinghouse Electric Corporation, Infilco Division.)
                                                         53

-------
                  Table I\\-8.-Operating data, primary skimming followed-by air flotation
Plant

A
p
J
Product

Beef
Beef
Pork
Head per day

1,100
1,000
300
Figure No.

lll-20(a)
lll-20(a)
lll-20(e)
System
capacity,
gal/min
1,000
1,500
100
Diameter
flotation unit

35 feet 9 inches
50 feet 0 inch
1 7 feet 6 inches
                                     Operating results reported
Plant
A
C
J
A
C
J
A
C
J
Chemicals added
None
None


None
Fe2(S04)3

None
Fe2(S04)3
Pollutant
Grease
Grease


BOD
BOD

Suspended solids
Suspended solids
Influent,
mg/l
1,150
2,150


1,710
1,306

6,200
1,380
Effluent,
mg/l
150
213


760
200

410
60
Percent removed
87
90


55
85

93
95
Table III-8 reports data for these systems.

     There are many other proprietary devices, processes, and mechanical details that, it is claimed,
enhance the efficiency of gravity separation and dissolved air flotation—too many to recount here.
It must be stressed again that the system must operate, in pilot scale, on the wastewaters from the
packing plant in question for several months before its value can be established for that particular
plant.
                                               54

-------
                                      Chapter  IV

                                  CASE  HISTORIES

                                          CASE 1

     A hog killing plant of medium size in Iowa, producing fresh pork with no further processing
other than edible and inedible rendering, has reduced BOD to 2.5 to 3 pounds per 1,000 pounds
live weight kill mainly by way of water conservation. The plant kills about 504,000 pounds live
weight using only 58,000 gallons of water.  Peak kill reaches  544,000 pounds and peak water use
78,000 gal/day, with a minimum of 33,000 gallons on any operational day.

     Yards and pens are all dry cleaned, using a manure spreader for direct disposal on farmland.
The blood floor is prerinsed with a small-diameter hose equipped with a fan nozzle using water at
600 pounds pressure. The small amount of rinse water, 35 to 50 gal/day, goes to the blood tank.
All blood is dried.  The extra drying cost for the prerinse water is small compared with the cost
saving in BOD reduction in final cleanup.

     The plant is equipped with edible and inedible dry rendering, but paunches and edible stomachs
are washed, and the wastewater is discharged to the sewer. The possibilities of further improvement
in waste conservation by dry dumping have not been explored.

     The plant produces a substantial saving in solids and BOD by its procedure in dumping the
scalding tub.  The tub is fitted with a drain 6 inches above the bottom of the tub, draining through
a 2-inch line.  The slow drain permits the sludge to settle. Then the residual sludge is scraped and
shoveled to a large sluice gate that is kept closed during drainage. The sludge is hauled to farm fields.

     The dehairing operation uses only 6 gallons per hog at 250 hogs per hour, with five men shaving
and trimming. The wet hair is sold.

     The grease sewer discharges to a small gravity catch basin 5 feet wide and 6.5 feet long, with
a sloping end. A single scraper chain mechanism serves to drag the bottom sludge up the sloping end
to a trough, and also pushes the scum to a scum trough.  The scrapers ride up a beach at the scum
trough and thence over the trough to complete the circuit. Bottom solids  and skimmings go to
rendering.

     The effluent of this basin joins the nongrease sewer at a 12-foot-diameter holding sump, from
which a 400-gal/min pump discharges to a circular dissolved air flotation unit also rated at 400
gal/min. The ratio of recycle to raw flow is 1 to 4. No chemicals are used. The effluent flow then
is discharged to a portion of the pump sump, walled off to carry the effluent to lagoon treatment
(the wastewater could be considered ready for discharge to a city sewer at this point). The walled
portion of the pump sump is arranged to recycle effluent through the flotation unit  during low-
flow periods, to insure uniform treatment in the flotation unit.

     The plant is washed down by a contract janitorial service after plant personnel dry clean the
floors and equipment to remove scraps.  The initial rinse on the blood floor is done by plant per-
sonnel.  All driers are equipped with sprays for cleaning in place.

     The owner gives major credit to water conservation for his overall success in reducing BOD as
well as water  consumption.
                                            55

-------
     It should be noted that the operations at this plant are limited to slaughtering and rendering.
Since individual process wastes in the rrieat industry have not been evaluated systematically, it is
impossible to predict the effect of additional processing on the results of these wastewater con-
servation data.
                                           CASE 2

     A large meat packing plant, killing 470,000 pounds live weight beef and 1,380,000 pounds
live weight hogs, operates a complete pork-processing system that includes smoking, sausage manu-
facturing, and curing, as well as sliced luncheon meat, canned meats, and lard manufacturing.  The
plant discharges less than 4 million gallons of wastewater daily and recycles 1,100,000 gallons of
wastewater daily for various purposes in the plant.  Blood is coagulated and the bloodwater is
evaporated.  Hides are sold green. Three-quarters of the hog hair is sold, the remainder going to land-
fill.  Paunches are washed and the manure is removed by screening before the wastewater joins the
major wastewater stream.  The plant operates  a laundry for shrouds and work clothes, and washing
facilities for all rail cars. Tripe and stomachs are washed, but casings and chitterlings are tanked
direct. Viscera are hashed and washed. Wet rendering is practiced for continuous edible rendering
and for inedible rendering of skimmings. Pretreatment consists of screens, gravity catch basins,
and dissolved air flotation.  Manure sewer wastewaters are screened separately.  The raw BOD is
1,600 mg/1, suspended solids 1,750 mg/1, and grease 800 mg/1. After pretreatment, these data drop
to 850 mg/1 (47-percent BOD removal), 500 mg/1 (71-percent suspended solids removal), and 150
mg/1 (81-percent grease removal).
                                             56

-------
                                      Chapter V

                                     SUMMARY

     In any effort to improve the quality of the wastewaters from a meat packing plant, the first
step must be a complete evaluation of in-plant waste-conservation opportunities. These opportuni-
ties include

     •  Recovery of product

     •  Removal of solid wastes and inedibles at the source (dry, where possible)

     •  Recycling of waters, such as cooling water and can quenching

     •  Reuse of wastewater for inedible purposes, such as condenser water in the tank house

     In the offing, and possibly already inaugurated in many communities, are new regulations set-
ting forth pretreatment requirements and surcharge systems to charge back to the meat packer those
costs of municipal treatment for which he is responsible.  The cost of purchased water, plus the cost
of waste treatment (pretreatment costs plus municipal surcharges), and possibly the value of re-
coverable byproducts offer economic incentives for waste conservation. After all feasible steps in
waste conservation have been taken, the degree of pretreatment of the various waste flows must be
determined, first to satisfy regulations, and second to determine whether pretreatment beyond that
required legally will produce economic advantages. The basic pretreatment will be required by
law; any pretreatment beyond this base is an economic decision.  Thus there is an economic break-
point where the pretreatment can stop. Possibly the legal requirements are the stopping point and
nothing can be gained by going further.

     Other variables enter the picture.

     • Possibilities for  increases in municipal surcharges

     • Adequacy of the municipal plant to treat the wastewaters

     • General growth  potential of the community, both in industry and in population

The meat packer also must consider his own future business plans, such as changes in processing,
additional processing, overall expansion, or possible reduction in operations. If wastewaters are
treated by the packer for direct discharge to a watercourse, he must consider obsolescence of the
treatment plant, possible changes in legal requirements, and the costs that are part of a wholly
owned facility (taxes, maintenance, operation, amortization, etc.).

     Within these elusive variables, the meat packer must determine

     • The amount of in-plant waste conservation he should economically undertake. It should
       be noted, however, that a substantial amount of waste conservation often can be accom-
       plished at insignificant expense.
                                             57

-------
     • The degree of pretreatment (for each of the segregated plant waste streams) that he should
       undertake in order to arrive at an economic breakpoint.  For example, he may find that a
       small amount of biological treatment, beyond the physical and chemical treatment discussed
       in this study, will drop the BOD and suspended solids to a level equivalent to domestic sew-
       age, and that surcharges levied by the city based on plant wastewater concentrations beyond
       the level of domestic sewage will drop to zero.

     • Whether the long-range possibilities for increases in municipal surcharges warrant considera-
       tion of a completely independent wastewater treatment system that discharges to a water-
       course, thereby eliminating all dependence on the municipal system.

     Most of the biological treatment systems discussed in "Waste Treatment"6 are also applicable
to treatment before discharge to a city sewer, should such treatment become necessary to satisfy
municipal regulations or become economically feasible.

     There follows an outline suggesting procedures for developing a decision matrix for waste con-
servation and pretreatment before discharge to a public sewer.

     1.   Employ a waste conservation supervisor. In a small plant, this supervisor may have other
duties, such as safety engineering, and he may have responsibility for compliance with the Occupa-
tional Safety and Health Act.  In a large plant, a full-time waste conservation supervisor should be
employed. He should have some engineering background, preferably in environmental engineering.
He will be responsible for waste conservation surveys, flow measurement, sampling surveys, cost
analyses of waste conservation and treatment, and continuing surveillance of the waste conservation
and treatment program, including supervision of the operation of any treatment facilities.

     2.   Install flow measuring and automatic sampling to collect and analyze wastewater samples
at sufficient frequencies and over a sufficient length of time to develop data on flow during the
maximum hour and the maximum day, as well as on averages.

     3.   Make an in-plant waste conservation survey as detailed in this study. Develop annual costs
for each possible change to include

     • Amortized cost of improvements, installed

     • Power costs, such  as heating, cooling, and pumping for recycling and water reuse

     • Chemical costs, if  some in-house treatment is required in recycling a waste stream

     • Labor cost (maintenance and operation)

     4.   Make a study of possible pretreatment systems, with annual costs developed as in para-
graph 3.

     5.   Determine the annual cost of municipal surcharges if wastewaters are discharged to the
city sewers, and select in-plant improvements based on comparative cost. If wastewaters are dis-
charged to a private treatment facility for disposal to a watercourse, the same type of cost analysis
should be made.

     6.   Select the elements of paragraphs 3 and 4 that are justified economically.
                                            58

-------
     7.    Design selected improvements to achieve the required results, considering such elements
as

     • Flexibility for alteration and expansion

     • Operating skills required

     • Quantity of residual solids and grease and feasible means of disposal
                                              59

-------
THIS PAGE INTENTIONALLY
        BLANK

-------
                                      Chapter VI

               PANEL  DISCUSSION  ON  ODOR  CONTROL

                                     INTRODUCTION3

     Odor is the number one air pollution problem for the red meat and related byproducts in-
dustry.  While the actual quantity of foreign matter entering the atmosphere from the meat indus-
try is relatively minor, some of the materials can be quite odorous.  Years ago it would not have
been difficult to locate some rendering plants by simply "following your nose." The red meat
industry increasingly has been required to practice odor control to overcome nuisance complaints
and to comply with newly enacted air pollution regulations.

     Historically, odor control has been practiced as response to nuisance complaints. It is curious
that the standard for nuisance has changed over the years. What the public was willing to accept
even a few years ago is now unacceptable—a major reason for an increasing number of complaints.
Odor is now considered air pollution, and is unlike an abstract pollutant, like BOD, in that the
public feels expert in understanding when odors are present.

     In response to public awareness and demands, the various regulatory agencies have been in-
creasingly aggressive in enforcing requirements for odor control. The basic  compliance requirement
is to proceed on any corrective program that will result  in a reduction of odor complaints.  Any
meat packer with a nuisance odor problem is expected to conform at least to this level of
compliance.

     Meat packers now have additional odor-control requirements that in certain localities take the
form of specific ambient-air quality standards for odor or of specific emission limits for odors.

     The discussion of odor in quantitative terms continues to be a major problem to everyone—
those with the odor problems, those offering odor-control resolution know-how and equipment,
and the regulatory agencies that attempt to write and enforce meaningful regulations. The current
practice is to define odor in terms of the magnitude of dilution required to  attain a concentration
that will no longer present an odor. A quantity called an  "odor unit" now appears in many regula-
tions, as does "odor unit per cubic foot" or "odor unit per standard cubic foot."b Since "odor
units," or odor concentration, is strictly a dilution value, the term makes no comment on whether
the odor is pleasant or unpleasant. Nor do odor units distinguish between a single odor and a blend
of odors. For example, the odor units measured in the ambient air downwind from a packing
plant probably will not be the same if the sample is taken on a concrete parking lot instead of in
a field of pollinating plants. Adding to the complexity is the problem that control of odor in terms
of odor-unit removal does not necessarily mean that nuisance complaints will be eliminated.

     Current methods for deriving odor units are still subjective; panels of qualified individuals  are
used to sniff samples at various dilutions.9 The resulting odor-unit values are not absolute, and
they should not be used without qualification as to the  type of testing and the nature of the test
conditions.
     aPrepared by Kenneth M. Ries, of Armour and Company.
      Terms related to odor measurement and control are defined ir appendix B.
                                            61

-------
     Several methods for odor measurement are now in use (see app. B). These methods of deriving
a dilution value (odor units) are not equatable; a direct correlation would have to be demonstrated
to establish any relationships between two test methods.

     The subject of odor control has several features that make it unique to the field of pollution
control

     • While the technical profession is engaged in the elusive battle to quantify odor in  scientific
       terms, the lay public has no trouble at all in identifying odors.

     • Everyone comes equipped with instantaneous analytical devices (olfactory system) that
       are always "plugged in."

     • While many pollution  problems concern the matter of degree, odor for the public is nor-
       mally an on-off, or yes-no, proposition.

     • Odor, as such, is a property of a pollutant, and not the pollutant itself. Thus it is correct
       to say that odor can cause no disease, and why odor perception can actually be eliminated
       by dilution.

     • Totally effective odor  control for a period,  followed by a single day of malfunction of
       odor-control equipment, can generate more complaints than if no control equipment were
       installed at all—the downwind public is more apt to react to a sudden increase in odor or
       presence of a new odor than to a continual  background odor level.

     It is important to understand that odors originate from both point sources (stack or vent) and
non-point-sources.  Emission standards would be difficult to define for non-point-sources. In the
meat industry, the potential odor sources are  from  bacterial activity on organic matter, the heating
of animal matter, and the handling of warm animal matter.

     Odor control can be summarized as

     • Source control, where the odor is eliminated by means such as  sanitation and rapid handling

     • Confinement and treatment of unpreventable odors

     • Perception  elimination, for example, by dilution

     Further advances in control technology are necessary if adequate  odor control  is to be attained
within an economically and ecologically sound framework.  With the greatly increased interest  and
activity in the field of odor control, these advances are expected.


                                   PANEL DISCUSSION

     A.J.STEFFEN: It was originally intended to hold this odor-control discussion as part of the
session this afternoon.  You can imagine the problem we would have had in squeezing it in. The
idea of holding it tonight was  first to get it into the program because the meat industry wanted it.
Second, and this is a very special reason, we can assemble here a panel of experts who, incidentally,
are not affiliated with any odor-control  company and so are free to express themselves.  All of
these experts have had some problems and, I understand, are free to talk about them.

     First I would like to say a few words about this problem of odor pollution, and then turn
the meeting over to the panel. I would like to mention the fact that there are many, many ways  of
                                            62

-------
controlling odor. You can put in a counterodor, you can put in a scrubber. A point source is one
problem that can be corrected in one way. A general source is another problem that can be cor-
rected another way.

     Now I would like to introduce the panel—W. James Wells,  of Bell, Galyard & Wells, whom
you met this afternoon; Donald O. Dencker, from Oscar Mayer; William H. Prokop of the National
Renderers Association; and Kenneth M. Ries, from Greyhound  Armour, or is it Armour Greyhound?

     K.  RIES: Greyhound. Armour and Company is a wholly  owned subsidiary of The Greyhound
Corporation.

     STE F F EN:  Don Dencker and Bill Prokop are going to speak on rendering. Ken Ries is going
to take everything else in the plant. Jim Wells is going to take everything outside—odorless lagoons,
that sort of thing.

     First Ken Ries will give you a few impressions.

     RIES: Since Jim Wells is going to review odors outside the plant and Don Dencker and Bill
Prokop are going to discuss what I consider the most serious odor problem in the meat industry—
the rendering problem—it falls to me to pick up the pieces that  are left over.

     One whole category of odor sources has one thing in common in our industry, namely, the
points at which putrescible materials accumulate and at which bacteria can, with time, operate on
these materials in a suitable environment to produce objectionable odors. In this category of
general sources, livestock unloading areas and stockpens will be considered first. Paved stockpens,
of course, lend themselves  to prompt cleaning, and a prompt cleanup minimizes the odor. A
second area for attention is the handling of the manure collected in some of these pens (if that is
the method of solid waste disposal).  Prompt handling and good sanitation practices are the most
effective methods of minimizing odors from  these operations.  I know of  no more effective means
of solving these kinds of  problems other than these measures. Then it is hoped that dilution will
dissipate remaining odors.

     Here let me make one comment about dilution.  I know that "dilution" is viewed as a bad
term by many regulatory agencies. But dilution is, in fact, a. legitimate method of odor control  in
certain cases. Odor is not a pollutant, it is a property of a pollutant. Odor, itself, is not hazardous
to one's health; it is basically a problem in esthetics.  Where dilution can be demonstrated as a
method  of eliminating any  esthetic objection, then it should be viewed as a viable method of com-
plying with an odor-control requirement.

     Blood collection and storage is a third area in which objectionable odors from bacteria are
created.  Again the method of control is prompt handling.  Keeping blood on the floor just for a
few hours can result in serious problems from the standpoint of odor, so one should strive to remove
and handle this blood as  promptly as possible.

     Another odor source is paunch manure  handling. Odors can result from this activity, par-
ticularly where paunch manure is stored prior to disposal, whether by screening or by dumping  into
a truck or other conveyance for removal from the plant site. If left standing, paunch manure can
cause odors. Also,  the ultimate disposal of paunch manure presents some difficult odor problems.
One of the unsolved problems in the meat packing industry is development of an acceptable and
practical method for handling this type of solid waste.

     Another area for odor control is that of hide handling. Again, whether you store hides on  site
for delivery to processor or process them yourself, rapid handling and good sanitation practices  are
advised.
                                            63

-------
     Inside the packing plant itself, the scraps that hit the floor—be it in the kill area, or in cutting,
breaking, fabricating, or boning—produce waste matter.  If this matter is left on the floor, it can
cause odor problems. However, thanks to USD A, most federally inspected plants do not have a
serious problem from this standpoint, because these floor scraps must be picked up promptly.

     Last in the category of bacteria-generated odors from solids would be the entire area of solid
waste handling, be it trash or garbage. Long-term storage of solid wastes can cause some very
objectionable odors.

     There are other odor sources that should be mentioned briefly without going into detail; we
can do this in the questioning.

     Livestock trucks present problems; as any of you know who drive down a highway, there is
no question that a livestock truck can be odorous. Then, in some plants, feed is manufactured for
livestock, and improper control of dust from feed operations can present some odor. Dust control
usually resolves this odor problem.

     In a hog plant, a potential odor source is the operation where hog carcasses are singed, pro-
ducing a burnt, foul odor.  In many plants the practice has been to dilute this odor with  the exhaust
air being ventilated from the building. This practice has been effective.

     Another minor odor source is edible rendering.  Most  of you who are familiar with this process
know that the primary problem is one of vapors produced by cooking of the edible grease for the
recovery of the tallow.  These fumes are not particularly malodorous. Only fresh material of high
sanitary quality is handled.

     In some cases, plants that  process hides will produce collagen, and the unhairing operations
on hides can produce odors from the chemicals used. Again,  the odor-control technique used is
dilution.

     The other areas in the plant concern cooking—for example, boiling and, in the case  of con-
venience food preparation, searing of meat. Vapors are produced and, again, these are not particu-
larly objectionable.  They are noticed as odors in the building, but when discharged outside they
are usually not noticeable.

     One area in the plant is common to all packing plants—the refrigeration system. The refrigera-
tion equipment normally used employs the ammonia system.  Uncontrolled ammonia discharges,
of course, can be objectionable, and should be attended  to by mechanical improvements in the
refrigeration equipment.

     If these odor sources are significant, then vent air from the restrooms is also an odor source.
Again dilution is the technique selected, as is the case, for example, in this building.

     Meat smoking is one meat-processing operation that deserves special consideration.  This
operation  presents a third potential major problem area in addition to the two problems that will
be discussed by the  other panelists. The problem is twofold.  First the smoke—particulate matter
that is submicron in size—presents a visible emission. The smokehouse emission can be seen, and
sometimes violates some of the codes on opacity. The second problem is one of odor—in this case
the wood  smoke odor.  The meat smoking process concerns two operations; first the meat is
cooked and then is smoked in two separate periods of a batch cycle. In the cooking cycle exhaust
air is emitted to  the atmosphere. This smokeless exhaust does contain a slight odor. This odor
source is normally not considered objectionable, and emission controls are not required. The re-
maining portion of the cycle, where the smoke occurs, can present some odor problems, and in
some instances odor has been noticed downwind resulting in  a complaint.
                                             64

-------
     The current technology for control of smokehouse emission recommends treatment of this
odor, as it may be applicable in certain plants. The best technical solution is incineration. In this
method of control, the smoke-containing gases coming from the smokehouse are passed through
an afterburner. The waste exhaust itself has essentially no Btu value of its own, heat recovery is
often impractical, and incineration is normally required to be at or above 1,200° F, resulting in a
significant fuel requirement. The incineration approach has some serious drawbacks.  One is that
fuel for this purpose is getting scarce; second, the use of fuels other than natural gas has been
shown to produce more pollutants than are removed, due to the contaminants in the fuel. Equally
effective alternative control methods are not currently available.  At least one meat packer is
investigating various scrubber techniques, including the use of a scrubber and electrostatic precipi-
tation in combination. Liquid  smoking as an alternative process is being explored.  Another area
that must be explored is process modification. It is hoped that these developments will result in a
control method more satisfactory  than incineration.

     STEFFEN: Thank you. We  will let questions accumulate. Those of you who are thinking
about them please make a note of them. Perhaps you may decide later whether one of the other
panelists would be better able to answer your question than the one you had first selected.

     Now I would like to introduce Mr. Don Dencker who is an old packinghouse hand.  I have
known him for many years.  In fact, he hired Tom Roberts, one of our Purdue graduates, quite
recently, so we are almost related. Don is going to talk about the irksome problem of inedible
rendering odors. Rendering produces an odor that cannot be hidden.  It is easily identified as a
rendering odor. You cannot talk about it as being just an odor of prosperity.

     D. DENCKER:  We deal primarily with fresh stock—at least in Oscar Mayer, we have fresh
material—and this helps immensely.  There are a couple of terms that are used extensively in the
regulations as applied to the control of odors.

     One of the terms is "odor units." The regulation limits are usually based on odor units.  An
odor unit is the number of cubic feet of odor-free air required to dilute 1 cubic foot of odorous au-
to the point of detectability by a median number of observers in an evaluation panel.  In other
words, the odorous air is diluted so that most of the people cannot smell it, or cannot tell it from
the blank. Usually these evaluation panels have a minimum of 6 to 10 people, having a normal
sense of smell.

     Another term is "odor threshold," which simply means the least concentration at which odor
is detectable by 50 percent or more of the observers.  Regulation by odor threshold is infrequent
and I do not know whether it has really been enacted  where applicable to rendering. Threshold
limits were proposed a year or so ago in Illinois.  For instance, some of the odorous substances from
rendering operations are detectable at a part per billion. The proposed Illinois regulations spelled
out odor thresholds of some 100 substances, and  would virtually have  put every waste-treatment
plant in the State of Illinois in immediate violation. So the odor-threshold principle is fortunately
not too active, but there is extensive use of odor-unit regulations.

     Odor-control regulatory approach in the past was on the nuisance basis. If your neighbors
were unhappy and found some legal basis for charging you with interference with their just, due
right to a comfortable environment for living—or  if you bothered their outdoor picnic—you could
be slapped with a nuisance action. This approach has  been felt to be too subjective, so regulations
are now going to ambient-air intensity-concentration measurements. But this approach is just one
of switching from one rather vague approach to another very subjective judgment.  The approach
was based on  an ASTM method published in about 1957, and modified; it also uses an odor
panel—a group of select sniffers—to evaluate odor intensity, and to  determine if they could still
smell the odor after a dilution of 2 to 1 on residential, 10 to 1 on commercial, and 20 to 1 on
industrial sites, for example.
                                             65

-------
     Now the regulatory trend in many instances is toward specified emission limits from specific
processes. The EPA has taken this tack in preliminary efforts to develop new source emission
standards for the inedible-rendering industry. And, therefore, the original proposal is to limit the
emission to 200 odor units per cubic foot of emission from any point source within the plant.  The
problem of plant-ventilation air is not dealt with fully in this initial approach.

     The odor-regulation measurement techniques I have touched on briefly are the nuisance
approach (a certain number or a certain percentage of the people complain), the ambient-air
approach with a Scentometer  (or the ASTM method, Mills modification), and the stack- or vent-
emission rate in odor units.  The ASTM method is under fire.  The Tenderers, in particular, through
their Fats and Protein Institute in conjunction with EPA and with some support by the American
Meat Institute, have been working with the Illinois Institute of Technology. The IIT Research Insti-
tute has developed a dynamic, more accurate method of measuring odor levels that eliminates some
of the bias of the members of the panel that is built into the ASTM technique.  The EPA, at the
present time, is conducting a number of tests to evaluate the suitability or the reliability of these
subjective test procedures.

     Sources of emissions you probably all know within your respective plants are cookers, driers,
and evaporators. Typically you are venting or exhausting around 50,000 odor units per cubic foot,
which is a ballpark number. If you  have an exhaust rate of 500 cubic feet per minute, emission
is 25 million odor units per minute. I believe there is one State—Minnesota—that proposes to limit
any total emission to 1 million odor units per minute. So you can see what the problem is if you
have a good-sized rendering plant.

     Cookers, evaporators, tank-odor evaporators,  presses, expellers—all would be covered in new
source standards.  The EPA, in its new source standards, is also considering what it calls a "process-
ing tank," which is basically any open vessel that contains a rendered product at 160°  F, or 180° F,
or above.

     Blood driers are another  source of odor emissions. Typically, the blood-drier emission rate might
be 100,000 odor units per cubic foot.  Other areas are the material receiving area, the holding tanks,
and so on.  There are many, many odor-control methods that have been employed, tried, experi-
mented  with; but there are three basic  approaches that generally are followed.

     First, if you have a vaporous emission, condense the condensable odor fractions.  Then, either
vent to the atmosphere and depend upon dilution to handle the remaining noncondensables, or pass
the noncondensables through  an afterburner or a thermal destructor. The trick, of course, is to
condense the condensables.  By this approach you  may reduce your afterburner heat requirements
to 5-10 percent of a noncondensing approach.

     Condensers of various types are employed; the direct-contact type  of condensers with a cooling
water spray on the vapors, the shell and tube, the surface condensers, and air-cooled surface-type
condensers have been used in  a number of installations.  Afterburners have been used—the conven-
tional ones and those employing catalysts (catalyst fouling has been a problem). Even feeding the
noncondensable gases to boilers for boiler-makeup air is a good approach in some instances.

     I mentioned two of the three major methods—the vapor condensers and the afterburners or
incinerators. The third method is the use of scrubbers. IIT has conducted  extensive tests on scrub-
bers, and they appear to be a very good solution—perhaps the only reasonable solution when you
must handle the plant air. Scrubbers can be spray towers or packed towers using water or chemicals-
potassium permanganate, calcium hydroxide, chlorine,  or some other oxidant in the spray solution.

     Another approach that has been used with generally poor success is ozonation. Activated
carbon adsorption, chemical counteractant addition,  masking chemicals, and so on—these all have
limited effectiveness, in my opinion.

                                             66

-------
     To conclude, the other thing I did mention is that the Federal people are very much interested
in the odor-emission problem.  Apparently they surveyed the State regulatory agencies a couple of
years ago after passage of the Clean Air Act of 1970. The responses from the State air-pollution-
control authorities were that the most frequent odor problems were caused by rendering plants.
The EPA proceeded to start work on the new source-emission standards as required by the act.  The
first sources were some of the more critical industrial processes, such as sulfuric acid plants, cement
plants, and incinerators; the second group was to include inedible-rendering plants. My informa-
tion, through the National Renderers Association, is that this action is now being held in abeyance
because the authorities want to work on the more critical emissions that have a health effect. They
do not have the staff to attempt immediately to police the more nuisance type of odors.  This may
mean, though, that there will be more activities by individual States, counties, and cities. And it
may mean that individual requirements may be more stringent than a national Federal standard.

     I believe that is all I have to say for the moment. Thank you.

     STEFFEN:  Thank you very much, Don. Don has covered the general areas of control very
well.

     I wonder where this place of abeyance is, where everything is being held. We  heard about it
this morning from the EPA people; this standard was being held in abeyance for a while, and so on.
I am not looking for this place, because wherever it is, it has a pile of stuff.

     We also have Jim Wells with us.

     I must plead guilty to having caused some of the problems, I guess, with the odors from what I
consider  to be very good and inexpensive ways of treating  wastewaters. I have sometimes felt that
we were just changing from one problem to another. I hope that Jim has some of the answers
because,  frankly,  the only answer I had was to plant some  evergreens around the plant. Jim, it is
your turn.

     J. WELLS:  I did not have that down on my list of acceptable procedures for  correcting the
problem, but it may be a good  idea.

     In dealing with waste-treatment systems outside the plant, in particular, I feel that first we
should talk a little about lift stations, flow-measuring systems, and coarse screens.  In and around
the lift station there is a tendency to forget that this area is an odor source outside the plant.  How-
ever, any time that grease or solids accumulate for any length of time in the wet pit of a lift station,
or in and around flow-measuring equipment, or on coarse screens, you are going to have odors.
Unfortunately, nobody wants to spend time looking after anything outside the plant area—anything
that is not making money.  It is very difficult, because most of the personnel responsible for assign-
ing people on their staffs to do jobs must be able to show that those people are absolutely essential
to making money. Well, it is hard to show that you need somebody to make money in looking
after your waste-treatment system, but as time goes on, I think you will find that it is more and
more important that you assign an individual to this responsibility.

     You not only need good housekeeping in and  around the lift station, flow-measuring system,
and coarse screens. In settling tanks  and clarifiers it is very important to get the grease  off quickly
and to remove bottom solids continuously. I have seen too many  clarifiers with grease  about a
foot thick.  You ask, "How long has  it been since you cleaned this?"  They say, "Well, we clean
it every day, we clean it regularly." You know full well they do not.  After three or four of these
instances, you finally take someone aside and say, "Look,  I'm on your side, tell me what you're
doing here."
                                            67

-------
     Grease removal is an area you do need to look after. It is to your advantage, of course, to get
that grease off quickly in rendering.  The longer it stays, the more problems you are going to have
in trying to handle it.

     It is also important that you have a system for removing the bottom solids on the settling
tanks.  In a settling tank you remove the grease because it makes money; you are not worried about
what settles to the bottom because it does not.  If you say, "Well, I'll hose it down once a week,"
this tank is going to be a source of odors. It is going to be a problem in operation; it is going to
affect your grease operation. So you should remove those solids regularly.

     My next point is one that I think Al Steffen was alluding to—the matter of anaerobic lagoons.
As was discussed in our session earlier today, we remain convinced that anaerobic lagoons are a
boon to the meat packing industry and an essential part of a great number of systems.  But unless
we begin to approach the problem of odors from the anaerobic lagoons we are going to find some
continued reluctance on the part of certain States to approve them.

     As far as anaerobic lagoons are concerned,  we primarily have been relying on location to pre-
vent odors from becoming a problem.  You do not locate a lagoon within a thousand feet or a
quarter of a mile of anybody, and usually they are placed at least a half mile and preferably two
or three miles out of town.  Well, this really is just a dilution system, and one that does not always
solve the problem, depending upon temperature conditions.

     Further, there are  situations in which we have a problem maintaining a grease cover. We dis-
cussed some of these matters in the earlier session, so I will not go into them now—but it is essential
that we do maintain a grease cover.

     One other thing has been done. We have a plant at Sioux Center, Iowa (Supreme Packing Com-
pany), with a 6-foot board fence all the way around the lagoon. This fence does two things. First,
it helps to keep the wind off, which then helps to keep the odors from being dissipated. Further,
it keeps the cover from being moved around. Without protection you will find a weak cover on one
side one day and back on the other side the next, just because the wind is blowing.

     The latest thing that has come up concerning anaerobic lagoons is the matter of attempting to
develop a cover for them. Now to be sure,  a cover is an expensive system—probably costing in the
neighborhood of a dollar a square foot, or $43,000 an acre.  On the other hand, perhaps the alter-
natives to  the anaerobic lagoon are much more expensive, so it is still a relatively economical system.

     At Monmouth, 111., there is an anaerobic-lagoon cover in a meat packing plant. I visited that
plant a month or two ago, and took some pictures while I was there. I think I might show them
at this time to give you some idea of what the cover looks like, what it consists of, how effective
it is, and, perhaps, what some of the problems are.

     The cover at Monmouth is nylon-reinforced Hypalon.  There are nylon ropes that  stretch all
the way across the cover and are anchored into the side. There is a concrete parapet wall that runs
all the way along the bottom, all the way around the pond.

     The method of sealing around the edges was to bring the cover across, then double it back.
Then there are anchor bolts going through 2 x 4's that anchor down into the concrete.  The prob-
lems with  this design have been the nonuniform surface on the parapet wall, which has resulted in
some leakage of gas underneath the cover, and possible corrosion, which has caused a loss of seal.

     Incidentally, Monmouth was forced into a cover because the wastewater is very high in sul-
fates, and  there was a lot of hydrogen sulfide being given off. There was an attempt to try to keep
the system aerobic, but it was not successful.
                                             68

-------
     You can get some idea of the maze of ropes laid across. These channels are made of Styrofoam,
and are laid on top of the wastewater in the pond. Their purpose is gas collection, to remove gas
from the system. They have openings that bring the gas inside the collectors, and they are spaced
across the pond. Also, around the periphery of the pond, there is perforated PVC pipe that also
draws off gas. All the  piping is brought together down at one end; it is hooked to a gas compressor,
and the suction side is  then hooked to the pond.

     In a closeup of the parapet wall, you can see where the cover has been doubled through and
then back under; then  the bolt is clamped down.  I walked all the way around the periphery. There
were certain areas where you could tell the cover was leaking because the odor was very strong,
but, by and large, it had made a tremendous difference in the odors from the pond.  We did not
detect any odors when we walked away, only right down next to the pond.

     The gas compressor is inside. The suction line comes through a flexible connection, through
a plug valve, over an elbow, on down, and becomes the suction line that goes out to the anaerobic-
lagoon cover.  The building is not completely enclosed.  Probably a foot or two all the way around
is open to the atmosphere, so in the wintertime it is quite cold. In order to insure against freezing—
this gas is very moist—there are infrared lamps directed onto the piping.

     There is a pressure-reducing valve, a flame arrester,  and then a waste-gas burner located outside.
Quite a bit of flame can be seen coming out.  They are not adding any natural gas or anything—the
flame is from  the methane that is collected underneath the cover and is being burned.

     QUESTION: Do  they have any protection for hail, or rain, or things of this nature?

     WELLS: No. I would say that the cover material—nylon-reinforced Hypalon—is probably the
best material that they could have. You could get cheaper materials, but that is probably one  of
the best.  Whether it would stand up under a very intense hail storm, I do not know, but I would
say it would stand up as well as, or better than, most other products.

     QUESTION: How much did this cost?

     WELLS: I do not know specifically what this one cost. We ran though some costs for another
installation, and it looked like about a dollar a square foot.  I am not sure, but I would say cost for
this installation was very close to that figure. It might have been somewhat less, but—particularly
when you include the parapet wall, the cover, the ropes, the gas collection—probably $43,000  an
acre is not a bad figure to look at,

     QUESTION: Is there enough methane to keep it burning?

     WELLS: Yes, I would say so. You probably ought to have a propane or a natural gas pilot on
the system, but there is enough methane to keep it going. It will support combustion. You do not
need to plan to spend for natural gas or propane.

     QUESTION: What  are the nylon ropes for?

     WELLS: I would say that one purpose would be to make very sure the cover did not blow
away with a great big wind.  Second, gas bubbles will be  created underneath  the ropes. Particularly
if the system is operated  intermittently, if either the time clock fails to come on or the operator
does not have it set often enough or does not look at it, some gas bubbles will build up.  If the
compressor is turned off, a big bubble starts to form. And probably the ropes are just a means of
confining that bubble and keeping wind from being a problem.
                                            69

-------
     DENCKER:  This cover was designed after they looked at one at Greenville, Mich., at an
Ore-Ida potato-processing plant. That was why the ropes were added, to restrain big bubbles that
developed.

     WELLS: The Greenville cover was, I think, a 30-mil PVC. I went up there to see it.  It was
an anaerobic treatment system for potato waste, and there was a problem with some mountainous
bubbles.  I suspect that is why they used ropes, in this installation.

     COMMENT:  They would have to walk out and push the bubbles down with their hands.

     WELLS: The other thing I want to cover is the problem in aerobic lagoons in a spring-thaw
breakup.  Ycu have a functional system that works beautifully in the summertime; in the winter-
time an ice cover develops on it. But during a period in the spring, when the ice goes off, you do
have some odor problems. I want to suggest how you might resolve that particular odor problem.

     If you were to broadcast approximately 200 pounds of ammonium nitrate per acre over the
lagoon system, and then follow that with a makeup dosage of about 100 pounds  of ammonium
nitrate per acre every week until the end of this problem period,  it would help considerably.  This
method supplies nitrates in the form of NO3. The bacteria like that form of oxygen much better
than they do the sulfates, so they will take the nitrates first. So, if in the spring  your neighbors
get on you and the flack becomes a little much, this method will get you over the hump until
reaeration from wave action can bring the  pond back to an aerobic condition.

     QUESTION:  I have a question on that. What do you do about the ammonia?

     WELLS:  Well, we will assume that that is not a problem.  Otherwise, you will have to
treat it.

     STEFFEN:  That is in that place we call "abeyance."

     WELLS:  We could use sodium nitrate until the  authorities start cracking  down  on that.
But the idea is to come up with a cheap source of nitrates, and if you do not  like ammonium,
we will use something else.

     STE F F EN:  Thank you, Jim.  I am happy that these speakers left quite a lot of questions
untouched, on purpose.  We wanted to keep the subject somewhat—I almost said that phrase,
"in abeyance."  Perhaps we might pause for those of you who  have questions.  Please address
them to the speaker you think can  best answer; and he is free to enlist another of the panelists
or anybody in the audience who might have a good answer to the problem.  So, if you please,
come to the mike. If you  want to announce your name, fine.  If you do not want to,  fine,
too.  This is not going to be one of those  sessions with finger pointing. We are all here for
the same thing. We want some answers, and we want some low-cost answers.

     QUESTION: This is to Mr. Dencker.  I am wondering if you have done any work on
collecting the odors from expellers—in  incinerating them, scrubbing them, or something of that
type.  Also,  what about this problem of rendering-ventilation air?

     DENCKER:  We have solved our expeller odors so far by  diluting them, quite frankly.
I think this would be a good time to hear Mr. Prokop's remarks on rendering.  The National
Renderers Association had a real go-around, I think, on the matter of plant-ventilation air. They
have had many discussions with the EPA.

     W. PROKOP: Although my remarks  on odor control are  based primarily on experience
with rendering plants that are independent of meat packing or  slaughterhouse operations, they
                                           70

-------
can be applied also to the on-site rendering plants.  However, the packinghouse material and the
blood handled by these rendering plants are usually quite fresh. It should be recognized that
the independent rendering plants process a wider variety of raw material and that it usually is
older, which tends to result in higher levels of odor to be controlled.

     The primary source of high-intensity odors in a rendering  plant are the noncondensables
from the cooker  exhaust and those emissions resulting from the screw press operation.  These
emissions range in odor intensity from 5,000 to 100,000 odor  units by the ASTM syringe method.
Other sources of  high-intensity odor emissions include centrifuges, tallow-processing tanks, and
the perc pans, which  are open to the room atmosphere and receive the discharge from batch
cookers.

     The raw material is another source of odor, but  normally  it is not significant when processed
without delay. It is commonly  known that animal byproduct material deteriorates rapidly upon
exposure to air and sun. The quantity of odor emitted from the rendering process is affected
greatly by the degree of deterioration that has preceded the cooking process.

     No simple generalized approach for solving odor-control problems is applicable to all render-
ing plants.   Each  individual  situation must be evaluated separately  based upon the plant building
features, process  equipment, raw material, and so forth.  However, the Tenderer can improve
his odor-control capability by conducting the following periodic reviews.

     Confinement of high-intensity  odors, such as cooker noncondensables and screw press vents
within the system, should be evaluated.  Excessive emission of  fat  aerosols to the building
atmosphere  not only increases odor levels but deposits grease on platforms and walkways, causing
slippery surfaces  that relate  to OSHA safety problems.  Further, these excessive grease deposits
require increased  cleanup labor and water use, which  results in  additional wastewater treatment
to process the greater volume and higher grease concentration in the plant effluent.  The gasket
seals on cooker inlet and discharge  doors and the tightness of odor-pickup duct connections
should be checked periodically.

     With the advent  of continuous rendering systems, the ability to confine odors within the
equipment has been improved substantially. Manufacturers of these systems  are becoming more
concerned with equipment details that relate to  providing gasketed  seals where odor emissions
may occur (e.g., inspection covers)  and the location of suction  pickup vents for improved col-
lection of odor emissions. Even batch cooker systems have a potential for improvement. Some
plants have  provided their batch cookers with a  manifold duct  system separate from the exhaust
system to draw off odorous vapors  with low steam content as the  cooker is being filled through
the sealed dome.  Several attempts  have been made to provide  batch system percolation pans that
are essentially closed.

     The entrainment separator between the cookers and the condenser should be checked
periodically  to determine that it is efficiently removing any solid or fat aerosol particles in the
cooker exhaust.  An efficient separator not only will  improve product yield but will result in
less odor in  the noncondensables and less solids  and grease in the condensate that ultimately
must be processed in  a wastewater-treatment plant.

     The condenser that removes steam vapors from the cooker exhaust should be provided with
adequate cooling  capacity.  The condensate temperature should not exceed 120°  F to minimize
the presence of volatile odorous components of high intensity.  The barometric or direct-contact
condenser is generally  being replaced by either a shell-and-tube  condenser or  an air-cooled con-
denser because of the trend  to minimize water use and wastewater-treatment costs.  The air-
cooled condenser is preferred because water circulation is not required for cooling and condensing.
                                             71

-------
     Overcooking and overpressing should be avoided. These are operating problems and depend
on the operational techniques developed in relating product quality to process variables such as
cooker time and temperature.

     Odor-control equipment should be kept in good operating condition. Operating procedures
should be clearly defined to insure proper operation and control of odors.

     Good housekeeping and sanitation practices should be maintained to reduce odor emissions
from spilled material and to create a good visual image.  Cleanup water hoses should be provided
with automatic shutoff valves to conserve water.

     Neighborhood areas should be checked periodically for effectiveness of plant odor control.
Whenever a meteorological temperature inversion occurs, conduct your own odor investigation and
determine the effectiveness of your odor control under adverse weather conditions.

     Present odor-control methods used in rendering plants consist primarily of incineration and
wet scrubbing with chemical oxidant solutions.

     Direct flame incineration can be an effective method of control for relatively small volumes
containing high-intensity odors. These volumes normally are limited to 1,000-2,000 cubic feet per
minute, and the odorous streams being incinerated usually consist of cooker noncondensables and
screw press vents. It is particularly important to avoid excess air being drawn into the odor duct sys-
tem, because fuel costs increase significantly. Afterburners with heat recovery  sections have been
installed to process large volumes (up to 25,000 cubic feet per minute) of rendering-plant air that
contains odors. In spite of 50-percent fuel savings, however, the fuel costs were so excessive that
these units were soon abandoned in favor of wet scrubbing systems.

     Instead of providing an afterburner for incineration, with the related additional capital and
operating costs, it sometimes is feasible to use the boiler firebox to incinerate low-volume, high-
odor-intensity gases.  Maximum fuel economy is achieved by using the odorous stream as primary
combustion air; however, the necessary precautions must be taken to clean up this stream by re-
moving solid and fat aerosol particles before passage through the burner and controls.  Some boiler
manufacturers and fire insurance companies recommend against using this odorous gas as primary
combustion air. If the gas is used as secondary air, then additional fuel is probably required. Also,
the boiler must be equipped with suitable burner controls to insure that the minimum firing rate
is sufficient to incinerate the maximum volume of effluent gas passing through the boiler firebox,
regardless of the steam requirement.

     Current and future trends dictate severe fuel shortages. The supply of natural gas is dwindling
rapidly.  The availability of low-sulfur fuel oil is also decreasing. As a result, higher sulfur-content
fuels will have to be burned, resulting in increased sulfur dioxide emissions that will probably ex-
ceed the quantity of odorous compounds to be incinerated.  Further, fuel oil costs are increasing
at an alarming rate due to the fuel oil crisis that has developed during the past months.  For these
reasons, incineration as a method of odor control is expected to decline in the future.

     The use of wet scrubbing systems that employ chemical oxidant solutions to control rendering-
plant odor emissions has increased significantly during the last 2 years.  The use of chlorine and
sodium hypochlorite has exceeded the use of potassium permanganate as a chemical oxidant, pri-
marily because of lower costs and ease of handling in solution.  Sulfuric acid and caustic soda or
soda ash have also been used as chemical scrubbing liquids to effect further reduction of odorous
constituents to less-odorous compounds.
     STEF F EN: What do you do with the liquid effluent?
                                             72

-------
     PROKOP: The chemical oxidant solutions used in wet scrubbers normally are recirculated or
recycled to conserve water and minimize chemical and wastewater-treatment costs. Where the
strength of the solution is reduced to such a level that it has to be dumped, this effluent has to go
through a waste-treatment system.  If it goes into the municipal sewer system the pH would be
adjusted.  That certainly would be the minimum that would be done.

     The concept of balancing the oxidant chemical addition rate with the chemical use rate is
important to achieve most effective use and minimum cost.  It is advisable to treat gas streams con-
taining solid and fat aerosol particles with a preconditioning device, such as a low- to medium-
pressure-drop venturi scrubber, to remove this particulate before passing to the chemical scrubber.
Since the  mass of the particulate matter suspended in the gas stream may  exceed significantly that
of the gaseous odor components, the rate of chemical oxidant consumption could rise quickly be-
cause the  presence of the particles in the recirculating solution will tend to use  up most of the
oxidizing  agent.

     Relatively few wet scrubber systems are being operated that handle exclusively rendering
process air emissions containing high-intensity odors, as opposed to plant  ventilating air that may
contain these process emissions but diluted to a lower odor level.  A two-stage system consisting of
a venturi scrubber with water sprays and a countercurrent-flow packed-tower scrubber with  recir-
culation of sodium hypochlorite solution is treating a combination of raw feather storage odors,
feather  cooker and drier exhaust, blood drier exhaust, noncondensables and screw press vents.
A three-stage, crossflow, packed-tower scrubber with gaseous chlorine addition, dilute sulfuric
acid recirculation, and dilute caustic soda recirculation is treating a poultry byproducts plant
effluent consisting of feather drier exhaust and offal cooker noncondensables.  These scrubbers
are achieving up to 99 percent reduction in odor level where the scrubber inlet  odor concentration
ranged from 5,000 to 20,000  odor units (ASTM  method).

     Plant-ventilating-air-type scrubbers include two basic types. A countercurrent-flow,
horizontal-spray-type scrubber with either one or two stages is being used extensively, with soda
ash or caustic soda solution recirculated through the first stage, and gaseous chlorine addition to
water recirculated through the second stage. The two-stage system is normally  used to treat all
sources  of rendering odors present in the ventilating air and where odor-control requirements are
more stringent due to closer proximity of neighbors. The countercurrent-flow  packed-tower
scrubber is being used with a variety of chemical oxidants that include sodium hypochlorite  and
a sulfuric acid solution  containing a powerful oxidant that is regenerated by a simple electrolytic
cell. These scrubbers, too, are treating the high-intensity odor streams along with the plant-
ventilating air. These types of scrubbers are achieving up to 95 percent reduction in odor level
where the scrubber-inlet odor concentration ranged 200 to 2,000 odor units (ASTM method).

     Atmospheric dilution with a properly designed stack is an important part of the overall
solution to plant odor control. In order to obtain adequate dispersion of  odors, the stack height
should extend sufficiently above the roof to compensate for the location of adjacent buildings
and the  surrounding topography. Under normal atmospheric conditions, a hundredfold or more
dilution is expected with such a stack.

     The fundamental problem with odor control and governmental regulation of odor emissions
from industrial plants is the lack of a reliable odor sensory method of measurement. Considerable
attention has been given to analytical measurement of odor emissions from rendering plants  by
gas chromatography and other means. However, due to the number and complexity of odorous
compounds present in rendering-plant emissions, these methods are hopelessly complex and  expen-
sive for  routine use. As a result, the only practical approach remaining is to provide a measure-
ment based on the olfactory senses of the human nose.
                                             73

-------
     Odor perception by various individuals is highly subjective and can vary widely.  Odor sensory
evaluation conducted with nine-member panels at IIT Research Institute indicated that a tenfold
variation in sensitivity normally exists among panel members, and occasionally the difference is as
high as a hundredfold.

     The problem of odor perception is complicated further because different odor-level values are
obtained by the various odor sensory methods currently available, even though the same identical
odorous air sample is being tested.  These differences are due primarily to the method of presenta-
tion of the odor stimulus to the panel members. Two current methods of odor sensory measurement
are being used as a basis for compliance with State or local odor regulations—the ASTM syringe
method and the Scentometer method.

     The ASTM syringe method is currently specified in the regulations of three States to determine
the odor concentration of exhaust stack emissions. This method consists of taking samples in a
100-cubic-centimeter cylinder or a 250-cubic-centimeter glass tube, and then diluting the samples
with odor-free air to predetermined odor-dilution levels for presentation to a panel of eight persons.
Each panel member must smell momentarily a rapidly expelled pulse of odorous air from the 100-
cubic-centimeter syringe. The median odor threshold level is defined as that dilution level where
50 percent of the panel barely detects the diluted odor stimulus.

     This method lacks a defined procedure for odor stimulus  presentation, since the various odor
dilutions are to be presented randomly to the panel by mixing the order of strong or weak odor
stimuli. Sometimes a blank or odor-free sample is substituted to check the panel's reaction. Since
a weak stimulus is much less detectable after a strong one, this approach can result in a false
response. Further, this method has no satisfactory provision to check  the reliability of positive-
negative responses of the panel.  Odor sensory evaluation of a single sample normally requires
from 30 to 45 minutes.

     The Scentometer has a history of compliance use across the country as a measurement of odor
in the ambient air. This instrument consists of a small rectangular chamber that contains two snif-
fing tubes on top for insertion into the nostrils. Normal breathing draws the odorous air from the
surrounding environment through the bottom panel and also through the two side panels that
contain activated carbon to provide odor-free air for dilution.  The bottom panel is provided with
four holes of varying diameter to vary the dilution ratio. These holes correspond to ratios of
dilution to threshold of 2, 7, 31, and 127.

     The Scentometer has three basic disadvantages.  First, this instrument is normally used by only
one individual. Odor sensory responses by different individuals are highly  subjective, and  the
Scentometer method does not provide for the selection of an odor sensory panel to average high
and low individual responses.  Next, the construction of the instrument does not provide positive
means for an individual to isolate his or her nose from the odorous environment being monitored.
Depending on the individual's pattern of breathing and ability  to seal off the nasal passages with
the two sniffing ports, it seems reasonable to expect that any odor in the ambient air could bypass
the instrument and be sensed directly by the nose, thus resulting in a false  positive response.  Finally,
the Scentometer is inherently limited to diluting the odor stimulus to  four specified levels, and
there is no adequate provision for achieving a graduated degree of dilution between adjacent levels.
Since a number of Scentometer regulations are specifically setting limits at low levels (2 and 7 odor
units) to define an objectionable odor nuisance for either residential or nonzoned areas, it is essen-
tial to have available an odor sensory method that is capable of accurately  determining the odor-
dilution level at these lower levels.

     Our association has been extremely concerned about the  reliability of the ASTM syringe
and Scentometer methods.  As a result, we initiated a project under the Fats and Proteins Research
Foundation, Inc., with IIT Research Institute to develop a dynamic method where the diluted odor
                                             74

-------
stimulus is continually discharged at a controlled flow. The dynamic olfactometer is based on a
forced-choice triangle statistical design. One diluted odor sample and two nonodorous air blanks
are presented continually at each dilution level.  Each panelist is required to judge which of the
three ports is odorous and to signal a choice. The three ports are arranged in a circular symmetrical
pattern to achieve a double-blind sample presentation, since neither panelists nor the panel leader
know the correct choice until after the judgment is made. The results can be related to statistically
significant confidence levels.  For a nine-member panel, a correct choice by six panel members
would indicate a 95-percent confidence level that the choice did not occur by chance.

     The test work is essentially complete for applying this method to measure stack-emission odors.
This work includes relating the odor test results with those  obtained by the ASTM syringe method.
Work is now being initiated to apply the IIT Research Institute dynamic method to ambient-odor
sensory measurement and to relate  the results of the method to those obtained by the Scentometer.

     The EPA published in the Federal Register of June 11 proposed performance standards for
new stationary sources in seven industrial categories.  The rendering industry was omitted from this
group of industries and, therefore, no odor emission standards are being published at this time by
the EPA.  As a result, it is anticipated that there will be increased activity by the individual State
agencies to develop and promulgate new odor regulations. As indicated before, however, there is
considerable need for a reliable odor sensory method  of measurement to be available for compli-
ance use.

     RIES:  I have a comment on this subject, partially in answer to the question that was addressed
to Don. My comment concerns an  experience that Armour and Company had recently.
 4.

     In January 1973, an inedible-rendering plant was installed at a beef abattoir. The State regula-
tory agency had just before that time enacted a very stringent law that covered the area of render-
ing.  The regulatory agency asked that all ventilation air be incinerated, and the plant management
thought this was prohibitively expensive.  The State wanted some sort of control, so the compromise
position was to install a scrubbing device. This rendering installation has five batch melters, three
blood driers, and two expellers.  The melter tank vapors were conventionally handled by direct
water-contact condensing. This condensation removed about 95 percent of the original volume of
the melter vapors. The noncondensable gases remained.  Fresh material is rendered at this plant,
and this material is not odorous when introduced into the melter. Therefore the melter vapors, or
the noncondensable gases, are less odorous than the gases from rendering dead and decaying stock.

     The system that was installed for scrubbing incorporated the collection of the noncondensable
gases and ventilation air at selected  points just above the percolation pans, expellers, and blood
driers. A maximum of 1,000 cubic feet per minute were  handled from the hot well where the
noncondensable gases were trapped, and 9,000 cubic feet per minute were handled from the venti-
lation ducts with inlets above  the non-point-sources within the building. It was expected that
removal of this volume of air-would, in a large measure, remove most of the odor present in the
rendering building.

     We have just put this system on stream, and I have brought with me some test results. These
data are in the form of Hemeon test odor units.  For those who are familiar with odor testing,
there is an alternative device that has  not  been mentioned—a dilution analytical technique.0 The
device is used to derive odor intensity (or odor units) on a given air sample, which is, in essence,
the dilution ratio. This number, incidentally, is not directly correlatable to ASTM odor units, but
a recently published curve10 shows a correlation between these two techniques for deriving odor
units.d This curve is only a clue to  the probable relationship of values for odor units, and cannot
     cSee "Odor meter" in appendix B.
     dSee figure VI-1.
                                             75

-------
    1,000,000
      100,000
   o
   I
      10,000
       1,000
                                Best fit
                                                               45  line
                       I   I   I Ix    I     ill
            J	I
              I   I  I
           100
                             1,000
10,000

 AOU
100,000
1,000,000
    Figure \l\-\. Comparison of odor measurement techniques: ASTM odor units per cubic foot (AOU) versus
                 Herneon odor units per cubic foot (HOU). (After Johnson and Bourne.9)


be used without considerable qualification. The science of odorometry is still too new to permit us
to discuss odor units in absolute terms. The scrubber that we installed on the 10,000-cubic-foot-
per-minute ventilation system consisted of gas chlorine addition preceding two packed-bed cross-
flow scrubbers, each with water and chemical recycle.  The first packed bed used an acid scrub (10
percent sulfuric acid). In the second packed bed a 10-percent caustic scrub is used.  Mist eliminators
follow each packed  bed to prevent windage loss of chemicals. The total installed cost for the entire
10,000-cubic-foot-per-minute scrubber system and ducts was below $25,000. The gases coming in
to this unit were found to have 12,000 odor units, 32,000 odor units, 18,000 odor units, and 3,500
odor units on four random inlet samples.

     The degree of odor control was over 90 percent removal, with outlet-gas discharge odor con-
centrations of 500,  250, 300, 500, and, in one case,  1,600 odor units.  In the case of 1,600 odor
units, all the chemicals were removed from the scrubbing solutions and water alone was used. The
resulting odor removal was 54 percent. This was a good verification that the  chemicals do perform
the required technique of improving capture of odorous matter present in the exhaust air. The
regulatory agency is satisfied with this solution.

     QUESTION:  I want to ask about the Hemeon  units.  I understand that  they are on the order
of magnitude of four or five times the more conventional units, is that right? What is the correlation?

     RIES: The correlation curve I mentioned was published in a paper  by Charles A. Johnson and
Joseph R. Bourne, of Air Quality Systems, Carrier Corporation.10  At the end of the article  there
                                             76

-------
appears an. empirical curve showing a comparison of Hemeon odor units to ASTM odor units.6  At
values of ASTM units above 100,000 odor units, the Hemeon and ASTM methods seem to give
comparable figures.  But as the concentration decreases, the Hemeon odor unit tends to generate
higher odor unit values than the ASTM method. According to this curve, at very low odor con-
centrations, where ASTM values approximate 100 odor units, the comparable Hemeon odor units
are over 2,000.  The Johnson and Bourne article is the first publication I have seen that relates
these two types of testing.

     The Hemeon method was used in our case because of its convenience.  A panel of only three
people was used and the odor units for a given sample could be computed in about 15 minutes.
For evaluation of equipment performance, this analytical method was satisfactory for the regula-
tory agency.

     DENCKER: I had read that under normal control levels it would be pretty poor to depend
upon the Hemeon method, because if you wanted 200 odor units per cubic foot, the Hemeon
reading is liable to be 800 or 1,000.  The Johnson curve seems to point that out. That is one reason
I did not mention that method.

     For control of expeller odors we have not gone to scrubbers, but I have heard of installations
where they have collected the expeller gases and directed them to the makeup air for gas-fired
burners for ring driers. That approach might be applicable in some instances.

     ST E F F E N:  OK, anybody else now?

     D. NEUBAUER: My name is Dave Neubauer, with the Omeco-St. John Company. We talk
about odor units. I would like the opinion of any member of the panel or in the audience—when
we talk about measuring the odor units, at what point do they measure them? Where odor is
produced—say, at the expeller or at the percolator pan? At the discharge, or at the property line?
Or, in the case of a lagoon, at the lagoon? Or some distance away? I wanted to get some idea
what we might expect—of what we get in the present regulations, and what we might expect in
the future.

     DENCKER: As you point out, there are two different approaches. One is called the outside,
or the ambient-air approach, and was the original attempt at quantifying odors.  For instance, you have
a plant neighboring residential property.  With a Scentometer, a few years back, you would dilute
a cubic foot (or a known volume) of odorous air, or supposedly odorous air, blowing off your
property.  If you could not smell the odor at a dilution of 2 to 1 you passed. If you could smell it
at  a higher dilution you  failed. That is an ambient-air test method.

     But the regulatory  approach of the Federal Government is, I think, the more conventional
stack-sampling approach of actually measuring emissions at the point the exhaust leaves the build-
ing, or at some convenient place before any dilution takes place with outside atmosphere.  In this
case odor units are used. And part of the problem of making this approach worthwhile—at least
such is  the argument of many people in this area—is the attempt to adapt an ambient-air testing
procedure to a stack-emission procedure.  There is no set answer. The regulatory people might
choose to take the ambient-air approach at the property line, they might choose to take the spe-
cific stack-vent-emission approach at the plant building itself, or they might try to get you both
ways. You cannot tell.

     NEUBAUER:  Do you have any idea of the consensus of the existing State regulations—
whether Minnesota, or California, or locally? Are they property-line tests or tests at the emission
from the stack?
    eSee figure VI-1.
                                           77

-------
     DENCKER: I do not know. I would even hesitate to guess.  The Tenderers have taken a
survey.

     PROKOP:  I would say that there are probably more ambient-air standards than there are
stack-emission standards. And I sense that the States are going to be leaning toward the ambient-
air approach. This will take into account zoning—in other words, the residential, industrial, rural
areas. Offhand, I think this is a reasonable approach, because then different zoning would not be
stuck with the same stack-emission standard. I think the big problem right now is having a good
and proper odor-answer method.

     ST E F F E N:  Anybody else on any part  of this subject at all?

     J. MAZURA: Joe Mazura, Rose Packing Company, Chicago. The gentleman from Armour
stated that Armour smokes with natural woodsmoke.  I was wondering if his feeling is that incin-
eration is better than water scrubbing for that type of emission.

     RIES:  No, as I started to point out in my introductory remarks, incineration is currently
viewed as the best technology. It does destroy odor. You cannot disregard the fact that it does
work. My disagreement with this solution is that it is not economical; it is very costly to operate.

     The second disadvantage to incineration is that it produces more problems than it solves. To
give a test case, some figures were computed for a given plant just to show the magnitude of the
problem. At one processing plant, 65.8 tons of smoked meat are processed per day in 11 smoke-
houses.  This is done throughout a 24-hour period. Both direct stack testing and U.S. Public Health
Service emission factors, which in this particular case correlated fairly close to the actual emissions
from this process, indicated that processing this volume of meat produced a total of about 20 pounds
of particulate matter per day,  which is the smoke emission to the atmosphere. The organic load
in this emission was also about 20 pounds a day.

     Fuel oil use—a requirement in this case  because gas  was  not available from the gas  company-
would have been 1,170 pounds a day to burn these 20 pounds of organic matter. Now  that does
not make much sense. Computation of the anticipated discharge of pollutants from fuel oil
(assuming No. 2 fuel oil with sulfur at 0.5 percent) resulted in values of 83 pounds of sulfur dioxide
a day and 70 pounds of nitrogen dioxide a day. These 153 pounds of pollutants would be generated
by burning 20 pounds of organic matter. That does not  seem like pollution control in the right
direction.

     The scrubbing approaches previously mentioned may be quite a bit less costly and would not
generate oxides of nitrogen and sulfur. The  problem right now is that it may not have the odor-
control effectiveness of incineration. From testing performed to date, venturi scrubbing has been
found effective in removing particles larger than 0.3 micron in diameter, but removal of particles
smaller than 0.3 micron has not been achieved. Unfortunately, most of the odor is associated
with the smaller particles. Evaluations of odor removal via venturi scrubbing suggested  that, with
removal of almost all particulates down to 0.3 micron, only half of the odor units were removed
from the raw gases. Venturi scrubbing is effective in control  of visible emissions, but water scrub-
bing has not totally solved the problem of a  detectable odor in the atmosphere. This technology
is still under evaluation; scrubbing with chemical solutions reduces odors significantly.

     MAZURA:  My second question is, Can you foresee, say in the  year 1985, that regulatory
agencies will ask for the control of emissions from a smokehouse?

     RIES:  Our company has three plants that are under order  to control emissions right now—
so it is not 1985, it is now.  At this time, our plan is to not put incinerators in; we are going to do
something else. Our company is currently conducting studies to find a satisfactory alternative
solution to incineration of smokehouse exhausts.

                                            78

-------
     W. COLVIN:  Bill Colvin.  Are you being asked to control your odors or your particulate
emissions?

     RIES: Both.  The primary problem in smokehouse emission has always been particulate
emissions. People can see smoke coming out of the packing plant, and it is therefore an obvious
discharge and a candidate for control. The more recent regulations have identified smokehouses
as violators of opacity, and also have identified them as point sources of odor. Personally, I do not
particularly see them as odor sources. The smoke is not an objectionable odor. In most of the
plants where our company conducts smoking, the odorous emissions that drift downwind have
never been, to our knowledge, the source of any complaints.  However, regulations may require
controls of odor if the emission violates a specific odor emission regulation.

     R. GERHARD: I am Bob Gerhard with Hormel.  I have two questions. One may seem quite
far out, but it regards the equivalent of water pollution by 1982 zero discharge.  Is there any
possibility of that standard being applied to the odor area? Second, in the process of these various
rendering facilities, there is a lot of heat generated.  Has there been any approach so far by the
Government as regards thermal pollution?

     DEIMCKE R:  Well, some afterburners have some waste heat recovery, which I think is a good
approach in preheating the incoming stream to assist combustion. I do not like afterburners either.
I think they are a tremendous waste of a natural resource—of natural gas— and afterburners are
thermal polluters. In areas with a photochemical smog problem, such as Los Angeles, the regula-
tions lead to afterburners, and then  speak of ridiculously high operating temperatures.  Higher
operating temperatures increase the emission of oxides of nitrogen.  An afterburner is, as I see it,
in some instances a patch or bandage for the benefit of the public^they cannot see the smoke.
You do not have to operate the afterburner at 1,200° or 1,500° F for 3/10- or 5/10-second
residence time to get rid of the visible smoke.  If that is the requirement, you should operate it at
a minimum temperature, which may be only 600° or 700° F, just to eliminate the visible emission.
As to zero discharge, there is no such thing. It defies the laws of conservation of energy. In going
toward zero in one direction, you are bound to increase the problem in another direction.

     QUESTION: Where do we stand with this ozone treatment that some people have tried? Are
any of you familiar with that?

     DENCKER:  I will pass that on to Ken. He had an ozone installation at Sterling, 111., if I
remember right.

     RI ES: Yes, our company did have an installation of ozone equipment on a rendering prob-
lem. In this case, an inedible-rendering operation at an abattoir (where only fresh offal was ren-
dered) had melter vapors discharging to the atmosphere. In this particular plant an ozone genera-
tor was installed to introduce ozone directly into the wet vapor. Loss of ozone-generating efficiency
was experienced due to the high moisture content of the air near the generator.  The ozone
generator did produce ozone, however, when the air was dry. Company engineers observed that
the ozonator destroyed odors in the stream emission completely.

     This ozonation application was discontinued in favor of direct water-contact condensers.

     I do not want to leave you with the impression that ozone is no good.  The installation was  pri-
marily a field test, based on the manufacturer's recommendation,  and our knowledge of the prob-
lem. It was not intended to be an exhaustive experimentation on  the potential for ozonation in
controlling rendering odors. Maybe ozone does have an application in rendering-odor control,
particularly where the ozone can be contained. There is one problem that you must consider
when using ozone—in itself, it is a pollutant. The contact  of ozone with the gases must be con-
                                            79

-------
fined and controlled in a manner that results in no discharge of unreacted ozone. This additional
problem must be solved if ozone is under consideration.

     STEP FEN: Any other questions? Any questions on lagoons? We all are, I think, in agree-
ment with Jim.  I think we have at least a consensus here that the anaerobic lagoon has been a god-
send to the meat packing industry, and we would like to see its use continued. This is one of our
real problems.  Don, do you want to comment a little on the questions that you raised" to our
biologists?  I do not remember all the answers because I am not a biologist—maybe you can help
me out on that.

     DENCKE R:  Professor Steffen refers to purple sulfur bacteria. This form of bacteria is a
phenomenon that has been noticed in a number of lagoon systems that have had a high sulfur-
sulfide content. In the subject system, the bacteria have eliminated or greatly reduced the odors,
except that, as in the anaerobic process, bacteria are temperature sensitive.  I suspect that, if you
could construct a proper vessel for an aerobic lagoon—you would need light to keep the bacteria
happy, as well as enough water and enough food—they would then handle your hydrogen sulfide
problem under controlled conditions.  We played around with a very unsuccessful fishbowl pilot
plant.

     STEFFEN: Did you not find that the sulfur in the water had something to do with it?

     DENCKER:  Yes, the amount of H2S odor is directly related to sulfate content of the water
supply that you take into the plant. If you have a low-sulfate water, you probably will not have
an H2S odor problem from the anaerobic lagoon or its effluent. If you do have a high-sulfate water,
you are bound to have a problem, as I see it.

     STEFFEN: It is a rather interesting and rather important conclusion that the sulfates in the
raw water you are using in the plants, rather than the waste you are adding to the water, may well
cause some of the problems in the lagoon.

     W. HELLMANN: Bill Hellmann from Smithville Packing. You are saying, "Stay with the
anaerobic lagoon." In 1977 we are required to have the best practical method.  Is an activated-
sludge system going to be considered the best practical  method over an anaerobic lagoon? And if
so, if we are planning additions now, what route should we go?

     DENCKER:  Of course, when the authorities talk  about best practical treatment, they are
going to come up with the effluent standards relating back to best practical treatment. Whether
you go with a completely aerobic system, such  as activated sludge, or whether you go into a two-
stage system with anaerobic lagoons followed by perhaps extended aeration and nitrification, the
resulting effluents of those two systems could well produce comparable results, even to the point
where the partial anaerobic system might produce superior results. So that the adoption of best
practical treatment, in my book, will not necessarily rule out anaerobic lagoons.  We hope to keep
them as a tool—but remember that they are just one tool. They are not necessarily everybody's
answer.

     DENCKE R:  This is really the importance of the anaerobic lagoon—it is a first stage. When
you are dealing with a 1,500- or 2,000-mg/l BOD5 waste, straight activated sludge is a bit of a
problem. If you can knock that down with the anaerobic lagoon and then go into aeration, the
anaerobic-lagoon effluent can easily be converted to an aerobic condition. You can still  follow
with activated sludge, or any other type of treatment. But the anaerobic lagoon is a real, low-cost
means of knocking down the major part of the  BOD.

     QUESTION:  Do you think an aerobic lagoon following an anaerobic lagoon increases or
decreases air pollution?
                                            80

-------
     DENCKER:  An aerated lagoon following an anaerobic lagoon, I would say, obviously would
increase air pollution, because the effect would be that a portion of the dissolved hydrogen sulfide
in the anaerobic effluent is going to be discharged to the atmosphere before it is oxidized in an
aerated lagoon.  I do not think there is much doubt about that. We have been involved with an
aerated lagoon following an anaerobic lagoon where water sulfates were rather high, and we picked
up some high hydrogen sulfide levels, even around the aerated lagoon.  I am sure the reason is that
the hydrogen sulfide was dissolved in the anaerobic effluent, and the action of the aerators in an
aerobic lagoon released a lot of it to the atmosphere before it was oxidized.

     MAZURA: Joe Mazura again. Mr. Wells, do you have any information on the efficiency of
microscreens?

     WELLS: Several papers were prepared, in the Journal of the Water Pollution Control Federa-
tion, on the microstrainer installation at Hanover Park in Chicago.  This installation was done in
parallel with a sandfilter system, so there were data on both sand filtration and microstrainers
following a waste-treatment plant.  Several companies make these microstrainers. I would suggest
that the best data source is the Journal of the Water Pollution Control Federation.  The Hanover
Park installation was a good installation. I am sure there probably have been some since then. I
have a file at home that has those articles in it.  I can make a copy for you if you cannot run them
down.

     P. MINOR:  Paul Minor, EPA Office of Technology Transfer.  The Technology Transfer Sus-
pended Solids Manual has a section on microscreening.   You can fill in the card for your copy.

     STEP FEN:  I know there are  many, many problems in odor control that we have not even
touched tonight. Some of you are sitting on your hands.  Some of you are, I am sure, reluctant to
ask some of the more nitty-gritty questions.  You can maintain your anonymity. But we do want
you to come away from this meeting on odor control with a feeling that you have had answers to
your questions.  Do not hesitate. Anybody else now?

     We can now assume, then, that all the questions on odor control have been answered in this
panel, and that was far beyond my fondest hopes—in fact, it is  beyond my belief. But I am de-
lighted that the panel was so well informed, so well equipped, and so well prepared. In fact, one
panel member even brought some charts that no one can see but himself—which shows how bashful
even the panel is in giving information. Everybody seems to be very much afraid of this odor prob-
lem, and well we should be.

     Now for one serious note. Odor is pollution, and we are going to be  facing that fact in this
business. You cannot sweep it under the rug. It is going to be  with us.  We have to recognize it as
a problem. We have to see how far regulatory agencies will be going with us, whether they will
recognize that there are reasonable limits to what can be done. And, as was mentioned here,
there is the very fact of energy transfer from one phase to another. Put in an afterburner and you
create a temperature problem, and so on. And with the energy crunch, it  would be a little embar-
rassing for Washington to tell us to use all of these Btu's to get  rid of a small amount of odor.

     So there are real problems, I am sure, not only for you but also for the regulatory  agencies.

     PROKOP:  Professor, I do not like your definition.

     STEP FEN:  Of what?

     PROKOP:  Odor is not pollution.  It has to be objectionable in some . . .

     STEFFEN:  I am not saying what I think it is; I am saying what the regulatory people say it is.
                                            81

-------
     PROKOP:. Well, we hope that they stay in tne realm of objectionable odors. Chanel No. 5,
or musk oil, on your wife—I do not think of that as a pollutant, but it is an odor.

     STE F F EN:  Well, it might be even an attractant. And at my age that might be a problem too.
But some of us, I think, do not agree with the definitions of pollution as they are stated by the
regulatory agencies. I am not spelling out what I consider pollution to be; but I believe I can rightly
say that the regulatory authorities believe, and take the stand, that odor is pollution.  Don, am I
right about that?

     DENCKER:  I would say some authorities are more reasonable than others.

     STEFF EN:  What about it, you in EPA?  Is odor a pollutant?

     EPA  REPRESENTATIVE: I think if any of you have small children, and you pass by a manu-
facturing plant, and there is an odor—the first thing your children will say is, "Pollution." And I do
not think there is any question that an objectionable odor is pollution. How far we can control it
economically may be another question.

     STE F F EN:  But the word was an "objectionable" odor, and that is like a definition of pollution.
Pollution is anything that affects the quality of life.  There is a study underway at Michigan State
University that is being funded by the Federal Government to define the quality of life. When this
is done we will have a definition of pollution.

     PROKOP: I would like to make a comment on objectionable odors as regarding people of
different ages.  A gentleman by the name of Linvall, in Sweden, has been making a study of children
and odors.  Pre-school-age children find all odors very interesting, not necessarily objectionable.
It is after they are in school, and have been in contact with adults, that they find the odors are
objectionable.

     STEFF EN:  I can say from my own experience that I flunked the course with my  kids.  When
I was with Wilson and Company, my kids thought I had an odorous job. I remember when we went
to Albert Lea,  Minn., on the way out west with the kids.  The superintendent of the plant at that
time, Eddie Ruble, took the kids through the plant.  The two girls did not want to go through the
plant. I said, "You go with Eddie, he's got a convertible." So they went, and he started them
through the smokehouse where they could pull a hotdog off a smokehouse tree.  So they munched
hotdogs as they walked through the plant, and when they came back to the picnic park where my
wife  and I were sitting waiting for them to return, they said, "Daddy, you never told us how nice
it was in a meat packing plant." This is actually true. Eddie Ruble  had the right psychology.
Anybody else now?

     We will then adjourn, with thanks to the EPA for giving us this opportunity tonight.  And
thank you for being with us.  A particular thanks to our panel of experts. Thank you very much.
                                            82

-------
                     REFERENCES  AND  BIBLIOGRAPHY
References
     1 "Industrial Waste Profile No. 8—Meat Products," in series The Cost of Clean Water, p. 53,
Washington, B.C., Federal Water Pollution Control Administration, 1967.
     ^Federal Guidelines—Equitable Recovery of Industrial Waste Treatment Costs in Municipal
Systems, Washington, D.C., Environmental Protection Agency, Oct. 1971.
     3A. S. Johnson, "Meat," p. 36, ch. 2, in Industrial Waste Control, ed. by C. F. Gurnham, New
York, N.Y., Academic Press, 1965.
     4 J. L. Witherow, "Meat Packing Waste Management Research Program," 65th Annual Meeting,
American Meat Institute, Chicago, 111., Oct. 1970.
     5Beefland International, Inc., Elimination of Water Pollution by Packinghouse Animal Paunch
and Blood, EPA Project 12060 Fds, Nov. 1971.
     6U.S. Environmental Protection Agency, "Waste Treatment: Upgrading Meat Packing Facili-
ties to Reduce Pollution," Washington, D.C., EPA Technology Transfer, Oct. 1973.
     7D. O. Dencker, "Some Solutions to Packinghouse Waste Problems," 15th Wastes Engineer-
ing Conference, University of Minnesota, Dec. 1968.
     8W. J. Wells, Jr., "How Plants Can  Cut Waste Treatment Expense," Nat. Provisioner, July 4,
1970.
     9D. M. Benfordo, W. J. Rotella, and D. L. Horton, "Development of an Odor Panel for Evalua-
tion of Odor Control Equipment," J. AirPollut. Cont. Ass., 19, 101-105, Feb. 1969.
     10Charles A. Johnson and Joseph R. Bourne, "Rendering Plant Odor Control by Electro-
chemical Oxidation: A Case History," Syracuse, N.Y., Air Quality Systems, Carrier Corporation,
undated.
     11 American Society for Testing and Materials, "Standard, Method for Measurement of Odor
in the Atmosphere (Dilution Method),"  ASTM D-1391-57, adopted 1957.
     12J. L. Mills, R. T. Walsh, K. D. Luedtke, and L. K.  Smith, "Quantitative Odor Measurement,"
J. AirPollut. Cont. Ass., 13, 465-475, Oct.  1963.


Bibliography

     In addition to the references, which are cited in the text by number, the following sources may
be useful:

"An Industrial Waste Guide to the Meat Industry," U.S. Public Health Service  Publication No. 386,
     rev. ed., Washington, D.C.,  USPHS, 1965.
H. C. Brammer and D. J. Motz, "An Overview of Industrial Water Costs," Ind. Water Eng., Mar. 1969.
W. H. Miedaner, "In-Plant Waste Control," Nat. Provisioner, Aug. 19, 1972.
W. H. Miedaner, "In-Plant Wastewater Control," presented at Univ. Wis. Extension Program, "Waste-
     water Treatment in the Meat Industry," Apr. 1972.
N. L. Nemerow, Theories and Practices of Industrial Waste Treatment, Syracuse, N.Y., Addison-
     Wesley Publishing Co., Inc., 1963.
A. J. Steffen, "Waste Disposal in the Meat Industry, A Comprehensive Review." Proceedings, Meat
     Industry Research Conference, American Meat Institute Foundation, Univ. Chicago, Mar. 1969.
                                           83

-------
THIS PAGE INTENTIONALLY
        BLANK

-------
                                   Appendix  A

                LIST  OF  EQUIPMENT  MANUFACTURERS

     Following is a list of manufacturers8 of equipment discussed in this study. The types of equip-
ment are listed in the order in which they are presented. Any mention of products or services here
or elsewhere in the study is for information only, is not selective unless it is used to illustrate a
point, and is not to be construed as an endorsement of the product or service by the Environmental
Protection Agency or the authors.

     Although the list is intended to be complete, there may be some oversights. Such oversights are
not to be construed as reflecting on the merits of the product or service.

     The author will appreciate being advised of errata, in order to improve subsequent editions of
this list.
Blood Coagulation Prevention System
Static Screens (Wedge Bar):
     Bauer Hydrasieve .  .
     Static Sieves.
     Other Models
Vibrating Screens:
     "Selectro," "Gyroset," "Kelly"
     Other Models
Swift Research & Development Laboratories
  Chemical & Engineering Group
  119 Swift Drive
  Oak Brook, 111.  60521

Bauer Bros. Company
  Subsidiary of Combustion Engineering, Inc.
  P.O. Box 968
  Springfield, Ohio  45501
F. J. Clawson & Associates
  6956 Highway 100
  Nashville, Tenn.  37205
Dorr-Oliver,  Inc.
  Havemeyer Lane
  Stamford, Conn. 06904
Hendricks Manufacturing Company
  Carbondale, Pa. 18407
Hydrocyclonics Corporation
  968 North Shore Drive
  Lake Bluff, 111. 60044
Peabody Wells
  Roscoe, 111. 61073

Productive Equipment Corporation
  2924 W. Lake Street
  Chicago, 111.  60612
Allis-Chalmers Manufacturing Company
  1126 S. 70th Street
  Milwaukee, Wis.  53214
DeLaval Separator Company
  Poughkeepsie, N.Y. 12600
    "Manufacturer's address is given with the first entry only.  Thereafter only the name appears (indicates
address given earlier).
                                           85

-------
Vibrating Screens—Continued:
Rotary Barrel Screens:
     Allison Screen for Hide Brining
     North Green Bay Screen
     Other Models  ....
    Rotating Disk Screens
Eccentric-Weighted Horizontal Disk Screens:
    Aero Vibe	
    Sweco	
     Syncro-Matic
    Other Models
Centrifuges:
     Eimco
     Merco Bowl .
     Other Models
Gravity Grease Recovery and Separation:
     Hardinge	
Envirex, Inc., A Rex Nord Company
  Water Control Division
  (formerly Rex Chainbelt, Inc.)
  1901 S. Prairie
  Waukesha, Wis. 53186
Link-Belt Material Handling Division
  FMC Corporation
  300 Pershing Road
  Chicago, 111. 60609
Simplicity Engineering Company
  Durand, Mich. 48429

Green Bay Foundry and Machine Works
  Box 2328
  Green Bay, Wis.  54306
Green Bay*
Dorr-Oliver*
Envirex*
Link-Belt Material Handling*
Envirex*
Link-Belt Material Handling*

Allis-Chalmers*
Sweco, Inc.*
  6033 E. Bandini Boulevard
  Los Angeles, Calif. 90054
Eriez Syncro-Matic
  1401 Magnet Drive
  Erie, Pa. 16512
Hydrocyclonics *
Kason Corporation
  231  Johnson Avenue
  Newark, N.J. 07108

Envirotech Corporation
  Municipal Equipment Division
  100 Valley Drive
  Brisbane, Calif. 95005
Dorr-Oliver*
Bird Machine Company
  South Walpole, Mass.  02071
Beloit-Passavant Corporation
  P.O. Box 997
  Janesville, Wis. 53545
DeLaval*
Pennwalt Corporation
  Sharpies-Stokes Division
  955 Mearns Road
  Warminster, Pa.  18974

Hardinge Co., Metal Products Division
  Koppers Co., Inc.
  York, Pa. 17405
                                            86

-------
Gravity Grease Recovery and Separation—Continued:
     Infilco	Infilco Division, Westinghouse Electric Company
                                                901 S. Campbell Street
                                                Tucson, Ariz.  85719
     Other Models	Belco Pollution Control Corporation
                                                100 Pennsylvania Avenue
                                                Paterson, N.J.  07509
                                             Beloit-Passavant *
                                             Ralph B. Carter Company
                                                192 Atlantic Street
                                                Hackensack, N.J. 07601
                                             Chicago Pump Division, FMC Corporation
                                                622 Diversey Parkway
                                                Chicago, 111. 60614
                                             Clow Corporation, Waste Treatment Division
                                                1999 N. Ruby Street
                                                Melrose Park, 111. 60160
                                             Crane Company, Environmental Systems Division
                                                Box 191
                                                King of Prussia, Pa.  19406
                                             Dorr-Oliver*
                                             Dravo Corporation
                                                One Oliver Plaza
                                                Pittsburgh, Pa. 15222
                                             Envirex*
                                             Environmental Services, Inc.
                                                1319 Mt. Rose Avenue
                                                York, Pa.  17403
                                             Environmental Systems
                                                Division of Litton Industries, Inc.
                                                354 Dawson Drive
                                                Camarillo, Calif. 93010
                                             Envirotech*
                                             Graver, Division  of Ecodyne Corporation
                                                U.S. Highway  22
                                                Union, N.J. 07083
                                             Jeffrey Manufacturing Company
                                                961 N. Fourth Street
                                                Columbus, Ohio 43216
                                             Keene Corporation, Fluid Handling Division
                                                Cookeville,  Tenn. 38501
                                             Lakeside Equipment Company
                                                1022 E. Devon Avenue
                                                Bartlett, 111. 60103
                                             Link-Belt Environmental Equipment
                                                FMC Corporation
                                                Prudential Plaza
                                                Chicago, 111. 60601
                                             Walker Process Equipment, Inc.
                                                Division of Chicago Bridge & Iron Company
                                                Box 266
                                                Aurora, 111.  60507
                                             Zurn Industries,  Inc.
                                                1422 East Avenue
                                                Erie, Pa. 16503


                                           87

-------
Dissolved Air Flotation:
    Graver "Aerofloter"	Graver, Division of Ecodyne Corporation
                                               U.S. Highway 22
                                               Union, N.J. 07083
    Other Models	Black-Clawson Company
                                               Middletown, Ohio 45042
                                             The Carborundum Co.—"Pacific"
                                               Buffalo Avenue
                                               Niagara Falls, N.Y.  14302
                                             Envirex*
                                             Environmental Systems*
                                             Envirotech*
                                             Infilco, Westinghouse*
                                             Keene*
                                             Komline-Sanderson Engineering Corporation
                                               Peapack, N.J. 07977
                                             Permutit Company
                                               Division of Sybron Corporation
                                               E. 49 Midland Avenue
                                               Paramus, N.J. 07652
                                           88

-------
                                    Appendix  B

                       TERMS,  METHODS, AND  DEVICES

             USED  IN  ODOR MEASUREMENT  AND CONTROL

     ASTM method. American Society for Testing and Materials static method of diluting samples
via 100-ml hypodermic odor-free room, to derive the value of odor units per cubic foot of sample).11
     Dilution ratio.  The value odor units per standard cubic foot or dilution threshold.
     Dilutions to threshold, (d/t) The number of cubic feet of odor-free air that must be added to a
cubic foot of odorous air sample to produce a mixture at the odor threshold.
     Hedonic.  Involving the psychological range of feelings from pleasant to unpleasant.
     IITRI methods. Procedures and equipment developed by the Illinois Institute of Technology
Research Institute. Sampling procedure where sample is passed through an adsorbent tube where
odorous vapors are retained but water vapor passes on.  The tube is then sent to a central odor
science laboratory that elutes the sample from the adsorbent and performs instrumental analysis
and sensory responses.  Gas chromatographic analysis coupled  with sensory response to significant
peaks produces an odorgram specific for the sample.  Mass spectrographic analysis may also be made.
A new device called a "dynamic forced-choice triangle olfactometer" is being offered as a device for
improved odor measurement. (Contact Dr. Andrew Dravnieks, Technical Director, Odor Sciences
Center, IITRI, Chicago, 111.)
     Malodor.  An odor capable of producing an unpleasant reaction  when sensed by humans.
     Mills modification (to ASTM).  Static and dynamic methods for dilution of samples and pres-
entation to a six- to eight-member test panel in an odor-free room, to derive the value of odor units
per standard, cubic foot,  from a graphic solution on log probability paper.12
     Minimal identifiable odors. (MIO) The odor threshold, normally for pure  compounds.
     Odor.  The sensation resulting from the human sense of smell.
     Odor concentration. The number of cubic feet that 1 ft3 of sample will occupy when diluted
to the odor threshold; a measure of the number of odor units per 1 cubic  foot of sample, and ex-
pressed in odor units per  cubic foot (ASTM).
     Odor emission rate,  (ou/min) The product of the odor unit per  cubic foot times the volume
rate of discharge in cubic feet per minute (ASTM).  For a point discharge, the odor emission rate is
ou/ft3 X ft3/min = ou/min)
     Odor intensity. Odor concentration. The concentration expressed in terms of multiples  of the
odor threshold.  Note that intensity does not relate to the character, quality, or hedonic quality of
an odor.
     Odor meter.  A semiportable apparatus that dynamically blends  odor-free  or room air with
sample air from a plastic bag for presentation to a three-member test  panel, to derive an odor inten-
sity value for the sample. Developed and marketed by Hemeon Associates, Pittsburgh, Pa.
     Odor threshold. The odor concentration that produces a median odor detection response in
humans. Threshold is not an absolute value; it varies with changes in  the test method, test condi-
tions, test panel members, and many other independent variables. Many of the methods for deter-
mining odor  intensity involve a determination of the threshold for each sample.
     Odor unit, (ou) One cubic foot of air at the odor threshold (ASTM).; The quantity of any
odorous substances or of any given mixture of odorous substances that, w|hen completely dispersed in
1 cubic foot  of odor-free air, produces a median threshold odor detection response in humans  (Mills).
     Odor units per cubic foot,  (ou/ft3) The number of odor units in a cubic foot of sample.
     Odor units per standard cubic foot, (ou/stdft3)  The number of  odor units in a cubic foot of
sample at standard conditions (70° F and 14.7 psia).
     Olfactory.  Relating to the sense of smell.
     Organoleptic. Affecting or making an impression on organs of special sense (taste, smell,  sight).
                                             89

-------
     Scentometer. A device consisting of a portable clear plastic box with a sniffing port.  Beds of
activated charcoal provide odor-free air that is mixed in various dilutions with ambient air for deter-
mination of dilutions to threshold. Limited to 170 d/t.  (Developed by the U.S. Public Health
Service and commercially available from Barneby-Cheney, Columbus, Ohio.)
                                              90

-------
METRIC CONVERSION TABLES
Recommended Units

Description
Length





Area










Volume







Mass





Time





Force





Moment or
torque




Stress


Unit
metre

kilometre
millimetre
micrometre

square metre

square kilometre

square millimetre
hectare





cubic metre


litre




kilogram
gram
milligram
tonne or
megagram

second
day

year


newton





newton metre





pascal
kilopascal

Symbol
m

km
mm
/im.

m2

km2

rnm^
ha





m3


1




kg
g
mg
t
Mg

s
d

year


N





N-m





Pa
kPa
Application

Description
Precipitation,
run-off.
evaporation






River flow


Flow in pipes.
conduits, chan-
nels, over weirs,
pumping

Discharges or
abstractions.
yields



Usage of water


Density






Unit
millimetre








cubic metre
per second

cubic metre per
second

litre per second

cubic metre
per day

cubic metre
per year

litre per person
per day

kilogram per
cubic metre





Symbol
mm








m3/s


m3/s


l/s

m3/d


m3/year


I/person
day

kg/m3






Comments
Basic SI unit










The hectare (10000
m2) is a recognized
multiple unit and
will remain in inter-
national use.




The litre is now
recognized as the
special name for
the cubic decimetre.

Basic SI unit


1 tonne = 1 000 kg
1 Mg = 1 000 kg

Basic SI unit
Neither the day nor
the year is an SI unit
but both are impor-
tant.

The newton is that
force that produces
an acceleration of
1 m/s2 in a mass
of 1 kg.

The metre is
measured perpendicu-
lar to the line of
action of the force
N. Not a joule.



of Units

Comments
For meteorological
purposes it may be
convenient to meas-
ure precipitation in
terms of mass/unit
area (kg/m3).
1 mm of rain =
1 kg/m2

Commonly called
the cumec






1 l/s = 86.4 m3/d








The density of
water under stand-
ard conditions is
1 000 kg/m3 or
1 000 g/l or
1 g/ml.
Customary
Equivalents
39.37 in.=3.28 ft=
1.09yd
0.62 mi
0.03937 in.
3.937 X 103=103A

10.764 sq ft
= 1.196sqyd
6.384 sq mi =
247 acres
0.001 55 sq in.
2.471 acres





36.314 cu ft =
1.3079cuyd

1. 057 qt = 0.264 gal
= 0.81 X 104acre-
ft


2.205 Ib
0.035 o/=1 5.43 gr
0.01 543 gr
0.984 ton (long) =
1.1023 ton (short)







0.22481 Ib (weight)
= 7.233 poundals




0.7375 ft-lbf





0.02089 Ibf/sq ft
0.14465 Ibf/sq in

Description
Velocity
linear






angular


Flow (volumetric)




Viscosity


Pressure








Temperature









Work, energy.
quantity of heat






Power




Recommended Units

Unit

metre per
second
millimetre
per second
kilometres
per second

radians per
second

cubic metre
per second

litre per second

pascal second


newton per
square metre
or pascal

kilometre per
square metre
or kilopascal
bar

Kelvin
degree Celsius








joule





kilojoule

watt
kilowatt
joule per second



Symbol

m/s

mm/s

km/s


rad/s


m3/s


l/s

Pa-s


N/m2

Pa

kN/m2

kPa
bar

K
C








J





kJ

W
kW
J/s



Comments











Commonly called
the cumec















Basic SI unit
The Kelvin and
Celsius degrees
are identical.
The use of the
Celsius scale is
recommended as
it is the former
centigrade scale.

I joule = t N-m
where metres are
measured along
the line of
action of
force N.


1 watt = 1 J/s




Customary
Equivalents

3.28 fps

0.00328 fps

2.230 mph





15,850 gpm
= 2.120cfm

15.85 gpm

0.00672
poundals/sq ft

0.000145 Ib/sq in



0.145 Ib/sq in.


14.5 b/sq in.

5F
~9 ~17-77








2.778 X TO 7
kwhr =
3.725 X 10 7
hp-hr = 0.73756
ft-lb = 9.48 X
10 4 Btu
2.778 kw-hr






Application of Units
Customary
Equivalents









35.314 cfs





15.85 gpm

1.83X 10 3 gpm





0.264 gcpd


0.0624 Ib/cu ft






Description
Concentration


BOD loading



Hydraulic load
per unit area;
e.g. filtration
rates




Hydraulic load
per unit volume;
e.g., biological
filters, lagoons

Air supply



Pipes
diameter
length


Optical units



Unit
milligram per
litre

kilogram per
cubic metre
per day

cubic metre
per square metre
per day





cubic metre
per cubic metre
per day


cubic metre or
litre of free air
per second


millimetre
metre


lumen per
square metre


Symbol
mg/t


kg/m3d



m3/m2d







m3/m3d




m3/s

l/s


mm
m


lumen/m2



Comments







If this is con-
verted to a
velocity, it
should be ex-
pressed in mm/s
(1 mm/s = 86.4
m3/m2 day).


















Customary
Equivalents
1 ppm


0.0624 Ib/cu-ft
day


3.28 cu ft/sq ft

















0.03937 in.
39.37 in. =
3.28ft

0.092 ft
candle/sq ft


-------
U.S. ENVIRONMENTAL PROTECTION AGENCY • TECHNOLOGY TRANSFER

-------