Um;.-,-: Stales
Environmental Protection
Agency
Office of Air Quality
Planning and Standards
Research "mangle Park NC 27711
EMB Report 85-HWS-3
October 1985
Air
Hazardous Waste TSDF
Waste Process Sampling
Volume II:
Amoco Petroleum Additives Company, Wood River, IL
Reilly Tar and Chemical Corporation, Granite City, IL
Shell Oil Company, Wood River, IL
Texaco, Incorporated, Salem, IL

-------
                     Prepared for
         U.S. ENVIRONMENTAL PROTECTION AGENCY
     Office of Air Quality Planning and Standards
    Research Triangle Park, North Carolina  27711
                 HAZARDOUS WASTE TSDF
                WASTE PROCESS SAMPLING
                      VOLUME II.
  Amoco Petroleum Additives Company, Wood River, IL
Reilly Tar and Chemical Corporation, Granite City, IL
          Shell Oil Company, Wood River, IL
           Texaco, Incorporated, Salem, IL
                     October 1985


                     Prepared by
                   GCA CORPORATION
               GCA/TECHNOLOGY DIVISION
            Bedford, Massachusetts  01730

-------
                                   DISCLAIMER
    This Final Report was furnished to the Environmental Protection Agency by
GCA Corporation in fulfillment of Contract Nos. 68-01-6871, Task No. 37 and
68-02-3851, Task No. 8.  The opinions, findings, and conclusions expressed are
those of the authors and not necessarily those of the Environmental Protection
Agency.  Mention of company or product name is not to be considered as an
endorsement by the Environmental Protection Agency.
                                      ii

-------
                               TABLE OF CONTENTS






                                                                          Page




Introduction	      iv




Amoco Petroleum Additives Company Trip Report	     1-1




Reilly Tar and Chemical Corporation Trip Report	     2-1




Shell Oil Company Trip Report	     3-1




Texaco, Incorporated Trip Report	     4-1




Appendix A - Sample Identification Forms	     A-l




Appendix B - GCA Data Report Forms	     B-l




Appendix C - Radian Corporation Data Report Forms	     C-l




Appendix D - Analytical Procedures	     D-l




Appendix E - RCRA Part A Permit Profile Sheet	     E-l
                                  iii

-------
                                   INTRODUCTION

     Air emissions  from hazardous  waste  treatment,  storage  and  disposal
 facilities  (TSDFs) are currently  being  studied by  the  EPA  Office  of Air
 Quality Planning and  Standards  (OAQPS).   The  four  sites  described herein
 represent a portion of the  testing program undertaken  by OAQPS in an effort  to
 profile TSDFs  and  estimate  emissions.   The results of  the  testing will be  used
 as  background  information for possible  standards for TSDF  area source air
 emissions.
     Process sampling  of wastestreams at  the four sites was conducted.  In
 additions detailed information on all waste operations,  emission  controls  and
 operating practices was collected.  The  facilities were  selected  to increase
 the scope of TSDF  operations encompassed by previous case  study and testing
 programs.   An  effort  was  made to  expand  the data base  in terms of treatment
 operations,  waste  types and geography.
     The wastestream characterization, sample  analysis  and  waste process
 descriptions should supply  the necessary inputs to emission estimation
 techniques.  Liquid samples from  waste  treatment tanks and impoundments were
 obtained from  each site.  Sludge  samples from impoundments were taken where
 applicable.  The results  of these analyses are presented for each site.
     These four Illinois sites, visited  in November 1984, represent waste
 generators with on site treatment operations.  All four  are involved in the
 petroleum products  industry and include  a production field,  an oil refinery, a
 tar  refinery and a  petroleum additives manufacturer.   Sample analysis and
 process descriptions  reflect operations  on the day of  the  visit.   Included
with each trip report  is  a  summary of the analytical sample results,  the
 actual  analytical  results and the Part A Permit Profile  sheet  for the facility.
                                    iv

-------
            Section 1.
Amoco Petroleum Additives Company
          Wood River, IL
               1-1

-------
                               TABLE OF CONTENTS


Section

  I.     Introduction	 1-5

 II.     Wastestream Characterization Information	 1-7

III.     Facility Process Description	 1-7

 IV.     Sampling Information.	 1-9
              Sample Location Description	 1-9
              Quality Assurance	 1-11

  V.     Sample Analysis	 1-12
              Analytical Summary	,	 1-12
              Quality Assurance	 1-12
                                    1-2

-------
                                 LIST OF TABLES
Table                                                                    Page

 1  Model Input Data for Air Emission Release Rate Determination at
    Amoco Petroleum Additives, Wood River, IL	 1-10

 2  Liquid Sample Analysis from the Sludge Lagoon at Amoco Chemical
    Corporation in Wood River, IL	 1-13

 3  Liquid Sample Analysis from the Sludge Lagoon/Oil Layer at
    Amoco Chemical Corporation in Wood River, IL.	 1-14

 4  Liquid Sample Analysis from the Sludge Lagoon Water at Amoco
    Chemical Corporation in Wood River, IL	 1-15

 5  Liquid Sample Analysis from the Spray Pond at Amoco Chemical
    Corporation in Wood River, IL	 1-16

 6  Liquid Sample Analysis from the Spray Pond at Amoco Chemical
    Corporation in Wood River, IL	 1-17

 7  Solid Sample Analysis from the Sludge Lagoon at Amoco Chemical
    Corporation in Wood River, IL	 1-18

 8  Cross Referenced List of Submitted Samples Collected at Amoco
    in Wood River, IL	 1-19

 9  Quality Control Data for Analysis Conducted on the Samples
    Collected at Amoco in Wood River, IL: Surrogate Recoveries -
    Volatile Organics	 1-21

10  Quality Control Data: Duplicate Aliquots of Sample ACC-OMS-1C
    (GCA 41757) Spiked with Volatile Organics,
    Amoco, Wood River, IL	 1-23

11  Quality Control Data Matrix Spike Recoveries for Sample
    ACC-SL-1C (GCA #41761), Amoco, Wood River, IL	 1-24
                                    1-3

-------
                                TABLE OF FIGURES

Figure                                                                   Page

 1  Facility layout, Amoco Petroleum Additives,
    Wood River, IL	 1-6

 2  Disposal pond clean up process, and location and size of sludge,
    clear water and oil slicks, Amoco, Wood River, IL.	 1-3
                                 1-4

-------
Site:                         Amoco Petroleum Additives Company
                              Old St. Louis Road
                              Wood River, IL  62095
FCID:                         ILD006272629
Site Contact:                 Richard A. Sumner, Environmental Engineer
                              (618) 251-2228
Field Trip Personnel:         Andrew Baldwin, GCA/Engineering
                              James Thomas, GCA/Measurements
                              Richard Roat, GCA/Measurements
                              Chuck Vaught, GCA/Engineering
                              Richard Sumner, Amoco
Visit Time and Date:          9:00 a.m., 11/15/84
I.   INTRODUCTION

     The Amoco Petroleum Additives Company in Wood River, Illinois has been a
manufacturer of petroleum additives since 1983.  The company was involved in
oil refining from 1907 to 1981, but decreased demand has ceased these
operations.  Presently, Amoco employs over 285 workers and production includes
additives for lube oils, such as viscosity improvers and friction modifiers.
Amoco sells roughly 3 million gallons monthly to automotive oil companies.
     Past refinery operations were performed at the main plant with treatment
of wastewater via mixing, aeration, and settling of sludges in a series of
treatment ponds.  Treated liquid wastewater was discharged directly into the
Mississippi River.  Cooling water was cooled in a 35-acre cooling pond via an
active sprayer system.
     Presently the treatment of petroleum additive wastewater includes removal
of waste solids and biosolids via aeration and clarification in an enclosed
treatment facility.  Effluent is discharged to the Mississippi River.  The
facility layout is shown in Figure 1.
     The size of the main plant is 586 acres; the old treatment ponds occupy
an additional 120 acres.  Other oil refineries are located within a 1-mile
radius of the site.  A residential area is situated to the east.
Climatological conditions the day of the visit were sunny skies, air
temperature of 50°F, and southwesterly winds at about 20 to 25 mph.
                                    1-5

-------
                                                         RESIDENTIAL  AREAS
                                                       PRODUCT STORAGE TANKS
                                                           OLD REFINERY
                                                         COMPANY BUILDINGS
                                                                          PUMP HOUSf
                                                                           35-ACRE
                                                                           COOLING POND
                                                                           SYSTEM
MISSISSIPPI
   RIVER
      Figure 1.  Facility layout, Amoco Petroleum Additives, Wood River,  Illinois.

-------
II.  WASTESTREAM CHARACTERIZATION INFORMATION

     Hazardous wastes generated by the facility primarily include oil sludge
and solids from heat exchanger leaks and tank bottoms.  These were stored in
pond Nos. 1 and 2 and are now removed in the treatment process.  Solid sludges
removed by DAF or API separator units during treatment of petroleum additive
production wastewater are dried and landfilled.  Biosolids removed during
secondary clarification are recycled back to the treatment process.  Effluent
has always been discharged into the Mississippi River.  A more detailed waste
characterization was not available.

III. FACILITY PROCESS DESCRIPTION

     The wastewater treatment system in use when Amoco was an active oil
refinery was a series of polishing surface impoundments until 1977 as shown in
Figure 2.  Pond No. 2 served as a mixing lagoon; pond No. 1 served as a
storage lagoon for oil sludges and solids; and other lagoons were active
aeration and sludge settling basins.
     A separate treatment facility began operation in 1977, and Amoco has
begun cleanup of the treatment ponds.  An estimated 45 million gallons of
solids and sludges will be dried, chemically fixated, and stored in Pond No.
5.  Dewatering was expected to be complete by the end of winter, including
transport of wastewater from Pond Nos. 2 and 4 to Pond No. 3, via subsurface
pipes and drainage into a surge basin enroute to the treatment facility.  At
the time of the site visit the sludge storage lagoon (Pond No. 1) had an area
of standing water.  Waste oil from past refinery operations still floats on
the surface of most ponds as well.
     Treatment facility operations at Amoco include oil/water separation
followed by aeration via DAF (dissolved air flotation) unit processing.
Solids are bubbled to the surface, skimmed, belt-pressed, and sent to landfill
areas.
                                 1-7

-------
                           EFFLUENT  TO  MISSISSIPPI   RIVER
SURGE
 BASIN
                                          f
WASTEWATER -*	PROCESS
TREATMENT        WASTEWATER
                                                WHEN ALL PONDS  ARE DRY,
                                                SLUDGE WILL BE  EXCAVATED
                                                AND LANDFILLED  IN POND 5-
                                                DOTTED ARROWS INDICATE
                                                SUBSURFACE FLOW THROUGH
                                                PIPES.
                                                   SAMPLING LOCATION
     Figure 2.  Disposal pond clean up process, and location and  size of sludge,
                clear water and oil slicks,  Amoco, Wood River, Illinois.
                                           1-8

-------
Wastewater is further biotreated in tanks using four 150 horsepower aerators.
A secondary clarification step removes biosolids which are recycled back to
the treatment tank.  Effluent is eventually discharged into the Mississippi
River.  Currently, water from the former treatment ponds is also being treated
in this system.
     Since oil refinery operations have ceased, there is little need for
operation of the sprayer cooling system.  Basically, the 35-acre pond serves
as a reservoir for cooling water pumped-in below the surface via a small, open
tank.  From a waste standpoint, the pond is basically inactive.  On the
average, its depth is 8 feet, and well water is pumped in when evaporative
losses become significant.  A small oil slick has formed within the past
6 months, although the total surface oil content has drastically decreased
since refinery operations have ceased.  However, sulfide sludges are still
present on the pond bottom.
     Table 1 contains information necessary for estimating air emission
release rates of volatile organics from the cooling pond, sludge lagoon, and
old mixing lagoon at Amoco.

IV.  SAMPLING INFORMATION

Sample Location Description

     Three sources sampled (Figure 2) at the time of visit included:

          o    35 acre cooling pond,
          o    sludge lagoon (Pond 1), and
          o    the old mixing pond (Pond 2).
     Two quadruplicate liquid samples were obtained from the cooling  pond.
One liquid sample (ACC-SP-l) was obtained at the inlet  (16°C), the other
(ACC-SP-2) was taken at the outlet  (13°C).  These samples appeared slightly
cloudy.
                                    1-9

-------
     TABLE  1.  MODEL  INPUT DATA FOR AIR EMISSION RELEASE RATE DETERMINATION
               AT AMOCO PETROLEUM ADDITIVES, WOOD RIVER, ILLINOIS.
Cooling Pond
  Impoundment type:
  Operation:
  Typical throughput:
  Handling/transfer:
  Activity:
  Surface area:
  Average depth:
  Typical retention times
Sludge Lagoon (Pond 1)
  Impoundment types
  Operation:
  Activity:
  Dimensions:
  Surface area:
  Average depth:
Old Mixing Pond (Pond 2)
  Impoundment type:
  Operation:

  Handling/transfer:
  Activity:
  Dimensions:
  Surface area:
  Average depth:
Nonaerated
Continuous flow
10,000 gpm
Subsurface pumping
Storage
35 acres (1,524,600 ft2)
8 ft
150 hrs
Nonaerated
No flow in or out-drying
Disposal (inactive)
250 ft by 400 ft by 0-1 ft deep
100,000 ft2
1 ft where liquid present
Nonaerated
Continuous outflow, no input other than
  storm runoff
Subsurface flow to pond 3
Disposal (inactive)
450 ft by 500 ft by 6-8 ft deep
225,000 ft2
7 ft
                                     1-10

-------
     One duplicate soil core sample (ACC-SL-C) was taken from the solid
material in the sludge lagoon (Pond 1) and a quadruplicate liquid sample
(ACC-OM-1) was taken from the liquid phase in the sludge lagoon (17°C).
Another quadruplicate liquid sample (ACC-OMS-1), temperature 15°C, was taken
from the oil slick in the old mixing pond (Pond 2).  No splits were requested
by Amoco.

Quality Assurance

     Sampling procedures were employed as described in the Quality Assurance
Project Plan dated 30 October 1984.  Liquid samples were collected in
quadruplicate.  Soil core samples were collected in duplicate. The
quadruplicate liquid samples and the duplicate soil samples were returned to
the GCA Analytical Laboratory in Bedford, MA where they were received into the
sample bank.
     Sample custody and handling procedures included the use of sample tags,
chain-of-custody sheets, refrigeration of samples between sampling and
analysis, and shipping of samples in coolers sealed with custody seals.  In
addition, each sample was assigned a unique sample code which linked it to the
facility, the source, and the sample point.
     Some of the sample matrices and locations made it difficult if not
impossible to collect the liquid samples without air bubbles forming in the
40 ml VOA vial.  In every case repeated attempts were made to obtain the
highest quality samples.
     The samples from this facility which contained air bubbles include:

     Sample Number                      Air Bubble Size
      ACC-OMS-1A                            Small
      ACC-OMS-1B                            Small
      ACC-OMS-1D                            Small
                                     1-11

-------
 V.    SAMPLE  ANALYSIS

 Analytical Summary

      Tables  2  through  7  provide  the analytical summary reports  for all of the
 process  samples  collected  during the  site visit  (see Appendix A.).  These
 tables present the major compounds quantified by either GC/MS (GCA
 Corporation/Technology Division) or a multiple detection system (Radian
 Corporation).  The actual  data report sheets for each respective sample are
 provided in  Appendix B and Appendix C.
      Analytical  procedures are detailed  in Appendix D.  Aqueous po; amd soil
 samples  were analyzed  as indicated.

 Quality  Assurance

 Chain of Custody

      A set of  samples  was  received by GCA/Technology Division on November 19,
 1984  for volatile  organic  analysis (VGA).  Routine inspection upon receipt
 revealed the samples to  be clearly labeled and appropriately chilled.  Air
 bubbles  were observed  in some samples; these are noted in Table 8 under
 remarks.  Upon receipt the submitted  samples were entered in the Master Log
 Book  and assigned  GCA  Control Numbers as listed in Table 8.  Chain of custody
 procedures were  adhered  to and the samples were transferred to  the locked
 Sample Bank  for  refrigerated storage  until the time of analysis.  Sample
 custody  records were maintained  throughout all laboratory procedures.
 Duplicate samples were submitted  to Radian Corporation of Austin, Texas under
 chain of custody for volatile organic analysis (VGA).

 Quality  Control

     Quality control protocol for the determination of volatile organics
 included  the use of surrogate spikes, and matrix spikes.  Each  sample was
 spiked with a surrogate mixture containing d4~l,2-dichloroethane, dg-toluene,
and 4-bromofluorobenzene;  these recoveries are presented in Table 9.
                                   1-12

-------
                    TABLE  2.     LIQUID  SAMPLE ANALYSIS  FROM THE SLUDGE  LA5QQM  AT
                                AMOCO CHEMICAL CORPORATION IN HOGB RIVER,  ILLINOIS.
                                                                         a,b
          Major Caapcunds                           Concentration (ag/1)
          Cnlorofors                                       0.03
          TOTAL HALOBENATED HC  •                           0.03
          TOTAL UNIDENTIFIED HC                           11

          TOTAL HOM-KETKAHE HC -                           11
l
  Analysis of saaple 41754 by 6CA Corporation/Technology Division using 6C/HS.
b
  •g/I = ppa asstiiing a density of 1.
                                                  1-13

-------
                    TABLE 3.    LI3UID SAMPLE ANALYSIS FROH THE SLUDcE LAGOON/OIL LAYER
                                AT AttOCO CHEMICAL CORPORATION IN iiOGD RIVER,  ILLINOIS.
                                                                         a,b
          Major Coapounds                           Concentration (tg/l)
          Methyl ens chlorids                                 27
          TOTAL HALOGE.NATED HC                               27
          TOTAL 'JNISaTIFIES HC                             266

          TOTAL NON-BETHANE HC                              294
a
  Analysis of satple 41757 by GCA Corporation/Technology Division  using SC/HS.
b
  •g/I = pps assuiing a density of 1.
                                                  1-14

-------
                   TABLE 4.    LIQUID SAMPLE ANALYSIS FROrt THE SLUD6E LABDDN KATES AT
                               A.10CO CHEJIICAL CORPORATION IN JiQQO RIVER,  ILLINOIS.
          Hijor Compounds                           Concentration (ag/li
          Acetone                                           0.2
          Methyl ene chloride                                0.2
          TOTAL  HALCGEHATE3 HC                              0.2
          TOTAL  OHBEJiATE!) HC                               0.2
          TOTAL  UNIDENTIFIED HC                             3.0

          TOTAL  WHHCTHANE HC                              3.4


a
  Analysis of sasple 41761 by  BCA Corporation/Technology Division using SC/HS.
b
  •q/1 - ppi assuiing a density  of I.
                                                  1-15

-------
                     TABLE 5.     LIQUID SASPLE  ANALYSIS  FROM THE  SPRAY  POND AT
                                 AHQCQ CHEMICAL CORPORATION IN WJQD  RIVES, ILLINOIS.
 Major  Compounds
                                                 Concentration  lag/li
                                       Analysis  i
Analysis 2
1-Propanoi
2,3-Diiethylbutane
2,4-Disetnylpentane
3-ltetnylpentane
Acetone
8-?insR9
Benzene
Chlcrctors
Cydohexane
Insan
Iscsiitane
Isehexane
hsthylcyclonexane
Rethylene chloride
H-3utane
M-Octsne
Nechexane
TOTAL PARAFFINS
TOTAL OLEFINS
TOTAL ARGJ1ATIC HC
TOTAL HALOSENATED HC
TOTAL OXYSESATEJ" HC
0.004
0.01
0.02
O.S03
0.2
0.03
0.7 1.8
0.06 O.Oi
0.31
0.003
0.01
C.01
o.Oi
O.M 0.1
0.02
0.003
0.002
1.1
0.03
0.7 1.8
0.06 0.1
0.004
TOTAL SGN-aETHAKE HC
                                          0.7
   3.0

b
d
Analysis si saspls 4!7i6 by 6CA Corporation/Techncloay Division using SC/HS.

Analysis ai saaple 41764 by Radian Corporation using SC/HD.

sg/1 = ppa assuaing a density or 1.

Csncsntratisn of Qxygsnated HC not used in Total NHHi. caic-jlaticr..
                                                     1-16

-------
                  TABLE fa.     LIQUID SAMPLE ANALYSIS FSQii  THE  SPRAY  PQNQ AT
                              AMOCO CKH1ICAL CORPORATION IN  UOOD  RIVES, ILLINOIS.



Hajor Coapoiinds
Acetone
Methylsne chloride
N-Hexane
T-2-Hixsne
TOTAL PARAFFINS
TOTAL OLEFINS
TOTAL HALQ6ENATED HC
TOTAL OXYGENATED HC
TOTAL UNIDENTIFIED HC
TOTAL NON-METHANE HC

Concentration (
i
Analysis 1
0.4
0.6




0.6
0.4
1.2
2.2
c
»g/l)
b
Analysis 2

0.05
0.01
0.1
0.05
0.1
0.05


0.3
Analysis of saspie 41769 by 6CA Corporation/Technology Division using 6C/H5.

Analysis at saepls 41767 by Radian Corporation using SC/'HD.

•g/1 = ppa assuEing a density of 1.
                                                  1-17

-------
                    TABLE 7.     SOLID  SAHPLE ANALYSIS FROrt THE SLUDGE LAGOON AT
                                AHQCC CKBtlCAL CORPORATION IH WOOD RIVER, ILLINOIS.

Hajor Coipounds
N-Undecane
M-Hexane
N-Ncnane
M-Decane
B-Pinene
Liaonene
N-3utylbenzene
P-Disthylbenzene
Isoiieptane
(Hieptane
S-Hethyihssiane
N-Octane
H-Propylfaenzene
H-Ethyltolusne
Isofaittyibenzene
Indan
Indene
Chiorosethane
Methylene cnlcride
Benzaldehyde
TOTAL PARAFFISS
TOTAL K^INS
TOTAL AROMATIC HC
TOTAL HALOEENATEil HC
TOTAL OXYGENATED HC
TOTAL IWIDEHTIFIED HC

TOTAL NQN-KETHAHE HC
c
Concentration (ug/g)
a b
Analysis 1 Analysis 2
100
13
20
45
14
21
32
13
S
5
7
• b
9
6
5
7
7
5
11 &
9
670
140
150
11 14
10
3
d
11 990
b
Analysis of saiole 41314 headspace by 3CA Corporation/Technology Division  using 6C/.1S.

Analysis of sassle 41315 soil by Radian Corporation using a 6C/HD.

ug/g = ppi assusing a density oi 1.

Concentration of Oxygenated HC not used in Total KHHC calculation.

                                                 1-18

-------
TABLE 8.  CROSS REFERENCED LIST OF SUBMITTED SAMPLES
          COLLECTED AT AMOCO IN WOOD RIVER, ILLINOIS
Sample
Identification
ACC-OM-1A
ACC-OM-1B
ACC-OM-1C
ACC-OM-1D
ACC-OMS-1A
ACC-OMS-1B
ACC-OMS-1C
ACC-OMS-1D
ACC-SL-1A
ACC-SL-1B
ACC-SL-1C
ACC-SL-1D
ACC-SP-1A
ACC-SP-1B
ACC-SP-1C
ACC-SP-1D
GCA
Control No. Remarks
41751*
41752*
41753
41754
41755* SAB
41756 SAB
41757
41758* SAB
41759
41760*
41761
41762*
41763
41764*
41765*
41766
(continued)
                    1-19

-------
                              TABLE 8 (continued)
           Sample                     GCA
        Identification             Control No.             Remarks
        ACC-SP-2A                  41767*

        ACC-SP-2B                  41768

        AGG-SP-2C                  41769

        ACC-SP-2D                  41770*


        ACC-SL-C1                  41814

        ACC-SL-C2                  41815*


SAB = Small air bubble

* Submitted to Radian Corporation, Austin, Texas.
                                      1-20

-------
TABLE 9.  QUALITY CONTROL DATA FOR ANALYSIS CONDUCTED ON THE
          SAMPLES COLLECTED AT AMOCO IN WOOD RIVER, ILLINOIS:
          SURROGATE RECOVERIES - VOLATILE ORGANICS
Sample GCA
Identification Control No.
ACC-OM-1D
ACC-OMS-1D


ACC-SL-1C

ACC-SP-1D
ACC-SP-2C
Method Blank
Method Blank
Method Blank
Method Blank
41754
41757 MS
41757 MSD
41757
41761 MS
41761 MSD
41766
41769
01/09/85
01/10/85
01/11/85
01/15/85
Average Percent Recovery
Relative Standard
Deviation(%)
D8-
Toluene
93
88
105
87
98
94
90
97
88
87
83
83
91
6.6
Bromo f luorobenzene
125
74
82
80
82
74
90
71
114
62
90
80
85
18
D4-1.2-
D ich lor oe thane
86
94
108
87
62
95
102
94
91
105
59
124
92
18
                           1-21

-------
Duplicate aliquots of Samples ACC-OMS-1C (GCA 41757) and ACC-SL-1C (GCA 41761)
were spiked with a volatile organic mixture; results are shown in Tables 10
and 11.
     At this time there are no appropriate quality control procedures
available for this type of soil core analysis.
                                   1-22

-------
         TABLE 10.  QUALITY CONTROL DATA: DUPLICATE ALIQUOTS OF SAMPLE
                    ACC-OMS-1C (GCA 41757) SPIKED WITH VOLATILE ORGANICS,
                    AMOCO, WOOD RIVER, ILLINOIS.
Parameter
        Concentration (ug)
Expected     Aliquot A   Aliquot B
                      Percent     Average
                      Recovery    Percent
                      Difference  Recovery
1,1-Dichloroethene

Chlorobenzene

Toluene

Benzene
        50

        50

        50

        50
60

43

48

30
66

39

42

50
10

10

13

50
126

 82

 90

 80
                                   1-23

-------
           TABLE 11. QUALITY CONTROL DATA MATRIX SPIKE RECOVERIES FOR
                     SAMPLE ACC-SL-1C (GCA #41761), AMOCO,
                     WOOD RIVER, ILLINOIS.
Parameter
               Reported
Expected    Concentration (ug)
 (ug)       Spike A     Spike B
        Relative    Average
        Percent     Percent
        Difference  Recovery
1,1-Dichloroethene   50

Trichloroethene      50

Chlorobenzene        50

Toluene              50

Benzene              50
              70

              54

              55

              56

              30
60

42

46

46

28
15

25

18

20

 7
130

 96

101

102

 58
                                  1-24

-------
             Section 2.
Reilly Tar and Chemical Corporation
          Granite City, IL
               2-1

-------
                               TABLE OF CONTENTS


Section                                                                  Page

    I.   Introduction	  2-5

   II.   Wastestream Characterization Information	  2-6

  III.   Facility Process Descriptions	  2-6
              Lagoon Cleanup Operations	  2-6
              Process Wastewater Treatment	  2-9

   IV.   Sampling Information	  2-9
              Sample Location Description.	  2-9
              Quality Assurance	  2-10

   V.     Sample Analysis	  2-10
              Analytical Summary	  2-10
              Quality Assurance	  2-14
                                   2-2

-------
                                 LIST OF TABLES

Table                                                                    Page

 1  Description of the Impoundments at Reilly Tar and Chemical,
    Granite City, XL	 2-7

 2  Liquid Sample Analysis from the Leaching Field at Reilly
    Tar and Chemical in Granite City, IL	 2-11

 3  Liquid Sample Analysis from the Lagoon/Aerated Area at Reilly
    Tar and Chemical in Granite City, IL	  2-12

 4  Liquid Sample Analysis from the Lagoon/Calm Area at Reilly
    Tar and Chemical in Granite City, IL	 2-13

 5  Cross Referenced List of Submitted Samples Collected At
    Reilly Tar and Chemical, Granite City, IL	 2-15

 6  Quality Control Data for Analyses Conducted on the Samples
    Collected at Reilly Tar and Chemical, Granite City, IL.
    Surrogate Recoveries - Volatile Organics	 2-16
                                      2-3

-------
                                LIST OF FIGURES

Figure                                                                    Page

 1  Facility layout for Reilly Tar and Chemical Corporation,
    Granite City, IL	  2-8
                                   2-4

-------
Site:                         Reilly Tar and Chemical Corporation
                              Edwardville and 19th Sts.
                              Granite City, IL  62040
                              Mail Address:  P.O. Box 370
FCID:                         ILD006278360
Site Contacts:                William Justin, Director of Environmental Control
                              (317) 638-7531
                              Larry Purtle, Plant Manager
                              (618) 452-3141
                              William Roder, Research Chemist
                              (317) 247-8141
Field Trip Personnel:         Andrew Baldwin, GCA/Engineering
                              James Thomas, GCA/Measurements
                              Richard Roat, GCA/Measurements
                              Chuck Vaught, GCA/Engineering
                              Larry Purtle, Reilly Tar
                              William Justin, Reilly Tar
                              William Roder, Reilly Tar

Visit Time and Date:          9:00 a.m., 11/16/84
I.   INTRODUCTION

     Reilly Tar and Chemical Corporation is headquartered in Indianapolis,
Indiana; the subject of this trip report is the Granite City, Illinois,
facility, which is a tar refinery.  Reilly Tar buys coal tar from the steel
coking industry.  Creosote oil, one of Reilly Tar's final products, is a
byproduct of coal tar distillation.  The remaining residue is tar pitch that
is sold to the aluminum industry for anode binders, as well as to other
industries as roofing tar and roofing pitch.  There are about 40 fixed roof
product storage tanks on site, but no drum storage.
     Reilly Tar is in the process of cleaning up an old settling lagoon, as
mandated by new state regulations.  This operation should be completed within
2 years.  Reilly Tar also operates an above ground biotreatment system for
process wastewater.  All treated wastewater is routed to a discharge field,
where it either evaporates or infiltrates.
     Climatological conditions at the time of visit were sunny and clear
skies, an ambient air temperature of 34°F, and westerly winds at 10 to
15 mph.  No odors were noticeable.
                                  2-5

-------
II.  WASTESTREAM CHARACTERIZATION INFORMATION

     Waste handled by Reilly Tar and Chemical is the "wet cut" from coal tar
distillation.  This is, for the most part, phenolic waste at a concentration
of about 1000 ppm«  Other materials in the wastestream are polyaromatic
hydrocarbons such as naphthalene, pyrene, and phenanthrene, as well as trace
amounts of benzenes, toluenes, and xylenes.  A more detailed wastestream
characterization was not available from the facility.  The facility's Part A
Profile is attached (Appendix E); also in this Appendix is a copy of the most
recent update to their Part A Permit Application.

III. FACILITY PROCESS DESCRIPTIONS

     Information necessary for estimating air emission release rates of
volatile organics from the lagoon and discharge field are summarized in
Table 1..  Process operations and locations are shown in Figure 1.
     Because the only material entering the lagoon is storm water runoff, no
retention time or throughput was given.  According to company officials, the
lagoon probably will be cleaned out within 2 years.  The discharge field will
probably be inactive by 19S5.

Lagoon, Cleanup^Operations

     As mentioned earlier, Reilly Tar is in the process of cleaning up an old
settling lagoon.  The first part of the operation (currently in progress) is
in-situ biodegradation of hazardous materials present in the sludge at the
bottom of the lagoon; this is expected to decrease sludge removal costs
later.  The system was set up by Polybac Corporation, and was designed to
destroy naphthalene, phenanthrene, pyrene, and other two-, three-, and
four-ring hydrocarbons found in the sludge.  According to Reilly Tar
engineers, the process appears to be working.  Occasionally, when the lagoon
becomes too full due to accumulation of storm water runoff, water is pumped
from the lagoon to one of the biotreatment tanks, where it is treated and
released to the discharge field.
                                    2-6

-------
     TABLE 1.  DESCRIPTION OF THE IMPOUNDMENTS AT REILLY TAR AND CHEMICAL,
               GRANITE CITY, ILLINOIS.
Aerate
-------
NJ
oo
                   -It—K	K	M	K	H	H	K	K	H	»	H	*	H	*	*	*	*	*	*	K	»	M—-*	*	H	M	K	K	1

                                                                                                                           1

                                                                                                                           1

                                                       	                                                                   I
                                        EQUALIZATION          	                          '
                                            »• * U I*     I     L -   ji^-*^  •vnr*ir*tr'Ltv                        \          ^^  \         '



                             COOLING TOWER OVERFLOW
                                    S10RM WAFER
                                    STOKAGE
                             PROCESS
                          WASTEWATER
                           PROCESS
                        UNITS  OFFICES
   ABOVE-GROUND
       TREATMENT
   I  1     TANKS
                                                 -*—X—It-
                                                              KEY
 OCCASIONAL PUMPING

 AERATOR LOCATION

 FENCE


SAMPLING LOCATION
                                                                                                           DISCHARGE  FIELD  ,
                                  Figure 1.   Facility layout  for Reilly Tar  and Chemical Corporation,
                                               Granite  City,  Illinois.

-------
Process Wastewater_Treatment

    Most BTXs (benzenes, toluenes, and xylenes) present in the coal tar are
stripped out at the steel coking facility before the tar reaches Reilly.
Wastewater from processes at Reilly Tar is, thus, mostly the "wet cut" from
coal tar distillation (coal tar is 2 to 10 percent water when it arrives).
Wastewater contains approximately 1000 ppm phenolic waste, as well as some
polyaromatic hydrocarbons, and trace BTXs.
    The wastestream is routed through a storage tank, and then to an
equalization tank.  En route, the wastestream may be diluted with storm water
and cooling tower overflow stored in a nearby tank.  After equalization, most
organics present in the wastewater are biodegraded in 250,000 gallon above
ground biotreatment tanks.  The treated wastewater is then released to a
discharge field at a rate of about 20,000 gallons per day.  Reilly Tar
personnel stated that a sewer hookup to the Granite City sewer system will be
installed before the end of the year to accept the treated wastewater.

IV. SAMPLING INFORMATION

Sample Location Description
     Samples were taken at two locations (Figure 1):
          o    the aerated lagoon, and
          o    the discharge field.

     Two quadruplicate liquid samples were taken from the aerated lagoon.  The
first set of samples (RTC-L-1) was taken near one of the aerators; the surface
of the lagoon was foamed due to aerator action.  The second set of liquid
samples (RTC-L-2) was taken in a calmer section of the lagoon, near the  lagoon
discharge.  All samples were at 10°C when taken.
     A final quadruplicate liquid sample (RTC-F-1) was taken from the
discharge field.  Only the area directly next to the influent line was
sufficiently deep to obtain a liquid sample.  No soil core samples were
obtained.  No liquid samples were requested by Reilly Tar and Chemical.
                                    2-9

-------
 Quality Assurance

     Sampling procedures were  employed  as  described  in  the  Quality Assurance
 Project Plan dated  30  October 1984.  Liquid  samples were collected in
 quadruplicate.   The quadruplicate  liquid  samples were  returned  to the GCA
 Analytical  Laboratory  in  Bedford,  MA,  where  they were  received  into the  sample
 bank.   The  facility did not request  splits,  so none were taken.
     Sample  custody  and handling procedures included the use  of  sample tags,
 chain-of-custody sheets,  refrigeration of samples between  sampling and
 analysis, and shipping of samples  in coolers sealed with custody  seals.   In
 addition, each  sample  was assigned a unique  sample  code which linked it  to the
 facility, the source,  and the sample point.
     Some of the sample matrices and  locations made  it  difficult if not
 impossible  to collect  the liquid samples  without air bubbles forming in  the  40
ml VOA  vial.  In every case repeated attempts were  made to obtain the highest
 quality samples.

V.   SAMPLE  ANALYSIS

Analytical  Summary

     Tables  2  through 4 provide the analytical summary  reports for all of the
process samples  collected during the site visit (see Appendix A).   These
tables  present  the major  compounds quantified by either GC/MS (GCA Corporation
/Technology Division)  or  a multiple  detector system (Radian  Corporation).  The
actual  data report sheets  for each respective sample are provided in
Appendix B and Appendix C.
    Appendix  D outlines the analytical procedures employed.  Only aqueous
samples were  obtained  at  Reilly Tar.
                                   2-10

-------
                    TABLE 2.    LIQUID SAMPLE ANALYSIS FROM THE LEACHIN3 FIELD AT
                                REILLY TAR AND CHEHICAL IN GRANITE CITY, ILLINOIS

                                                                    c
                                                Concentration (as/I!
                                                  a                        b
Ssjar CsiBcanas                         Analysis 1               Analysis 2

Acetone                                     0.2
Careen tetrsehisride                                                0.03
fisthylens chiorise                          0.2                     0.05
TQTfil fcHLOSENATi:- HC                                                0.07
TOTAL UNIDENTIFIED HC                       6.0

TOTAL MON-ftETHASE HC                        6.0                     0.07
  Anaiysii at 5£.uBi3 -1772 iy 5CA Carcoratian/TgcnnaiDsy Division isino SC/fls.
b
  Analysis sf saapis 41773 ay Radian Corporation using SC/HB.
c
  ag/'i = 3Bi assuaing a sarsity 3t 1.
                                               2-11

-------
                     TABLE  3.     LIQUID  SAMPLE  ANALYSIS  PROS THE  LABOGN/AERATtB AREA AT
                                 REILLY  TAfl  AND CKEKICAL IN 5RANITE CITY,  ILLINOIS
                    jasaaaaasaaasasaaaasgagaaaasasaagaaA-jjssaasasj-JMaTaassaaraasasaaasaa
                                                                    c
                                                Concentration  (sa/1!

Hajar Caapcunss
1.2,4.-7ri3etf:yi!3enzsris
Acstsns
Cartsn tstracnicnae
Hetiwlene chiarida
N-'jRiecana
TOTAL PARAFFINS
TOTAL A50MTIC HC
TOTAL HALaSESATES HC
TGTAL OXYGENATED HC
TOTAL UNIDENTIFIED KC
T3TAL NON-NtTHANE HC
a
Analysis I

0.2

0.2

—--—------

0.2
0.2
2.0
2.0
b
Analysis 2
0.02

0.03
0.03
0.04
' oTbl
0.02
0.05
0.04

0.2
T -J - ;t:="i"=~~=r=r-;
a
  Analysis of sasscls 41777 by ECA Ccrporatian/Technciagy Division using SC/flS.
b
  Analysis or ssapla 41775 by Saflian Corporation using BC/JiO.
c
  iq/i = ppa assuing a density of I.
                                               2-12

-------
                    TABLE 4.    LI3UID SAMPLE ANALYSIS FF.QH THE LAGQOK/CALH AREA AT
                                REILLY TAR AND CHEMICAL IN GRANITE CITY, ILLINOIS



fiajsr Ccapounds
2,5-Diaethyihsxar.e
2-.1atnyl-2-3uteRe
Acstane
Kethyiene chioriss
TOTAL PARAFFINS -
TOTAL OLEFIHS
TOTAL HALSGENATED HC
TOTAL QXYEEHATED HC
TOTAL NGN-HSThftNE HC
========== =====r======:=s:r
Concentrition
a
Analysis 1


0.03
0.02
««»«»____..

0.02
0.03
0.05
c
(ag/1)
b
Analysis 2
O.G02
0.02

0.1
o"7i -
•0,02
0.1

0.2
a
  Analysis ar saapis 417B2 by 3CA Ccrsoraticn/Technology Division using SC/3S.
b
  Analysis or saaple 41779 by Radian Corporation using 3C/HC.
c
  ag/1 - psa assuiaing a dansity of 1.
                                               2-13

-------
Quality Assurange

Chain of Custody

    A set of samples was received by GCA/Technology Division on November  19,
1984, for volatile organic analysis (VOA).  Routine inspection upon receipt
revealed the samples to be clearly labeled and appropriately chilled.  Air
bubbles were observed in some samples; these are noted in Table 5 under
remarks.  Upon receipt the submitted samples were entered in the Master Log
Book and assigned GCA Control Numbers as listed in Table 5.  Chain of custody
procedures were followed and the samples were transferred to the locked Sample
Bank for refrigerated storage until the time of analysis.  Sample custody
records were maintained throughout all laboratory procedures.  Duplicate
samples were submitted to Radian Corporation of- Austin, Texas, under chain of
custody for volatile organic analysis (VOA).

Quality Control

    Quality control protocol for the volatile organics analysis included  the
use of surrogate spikes.  Each sample was spiked with a surrogate mixture
containing dg-toluene, bromofluorobenzene and d^.-!,2-dichloroethane.
Surrogate recoveries are listed in Table 6.
                                 2-14

-------
       TABLE 5.  CROSS REFERENCED LIST OF SUBMITTED SAMPLES COLLECTED AT
                 REILLY TAR AND CHEMICAL, GRANITE CITY, ILLINOIS.
         Sample                      GCA
     Ident i ficat ion                Control                 Remarks

      RTC-F-1A                      41171                    LAB
      RTC-F-1B                      41772                    LAB
      RTC-F-1C                      41773*                   LAB
      RTC-F-1D                      41774*                   LAB

      RTC-L-1A                      41775*                   LAB
      RTC-L-1B                      41776                    SAB
      RTC-L-1C                      41777                    SAB
      RTC-L-1D                      41778*                   LAB

      RTC-L-2A                      41779*
      RTC-L-2B                      41780*
      RTC-L-2C                      41781
      RTC-L-2D                      41782
SAB = Small air bubble

LAB = Large air bubble

*Submitted to Radian Corporation, Austin Texas.
                                   2-15

-------
TABLE 6.  QUALITY CONTROL DATA FOR ANALYSES CONDUCTED ON THE SAMPLES COLLECTED
          AT REILLY TAR AND CHEMICAL, GRANITE CITY, ILLINOIS.  SURROGATE
          RECOVERIES - VOLATILE ORGANICS
Sample
Identification
RTC-F-1B
RTC-L-1C
RTC-L-2D
Method Blank
Method Blank
Average Percent
GCA
Control No.
41772
41777
41782
01/09/85
01/10/85
Recovery
Relative Standard Deviation (%)
D8
Toluene
106
82
85
88
87
90
9
Bromo f luorobenzene
94
78
74
114
62
84
20
D4-l,2-
Dichloroe thane
99
72
99
91
105
93
13
                                  2-16

-------
    Section 3.
Shell Oil Company
  Wood River, IL
     3-1

-------
                               TABLE OF CONTENTS






Section                                                                  Page




   I.    Introduction	 3-5




  II.    Wastestream Characterization Information	 3-5




 III.    Facility Process Description.......	 3-7




  IV.    Sampling Information	 3-7




              Sample Location Description	 3-7




              Quality Assurance	 3-10









   V.    Sample Analysis	 3-11




              Analytical Summary......	 3-11




              Quality Assurance	 3-11
                                   3-2

-------
                                 LIST OF TABLES
Table                                                                     Page

 1  Model Input Data for Air Emission Release Rate Determinations
    at Shell Oil, Wood River, IL	  3-9

 2  Liquid Sample Analysis from the Biotreatment Pond #2 at Shell Oil
    Company in Wood River, IL	  3-12

 3  Liquid Sample Analysis from the Surface Impoundment Influent at
    Shell Oil Company in Wood River, IL	  3-13

 4  Liquid Sample Analysis from the Surface Impoundment at Shell
    Oil Company in Wood River, IL	  3-14

 5  Liquid Sample Analysis from the Surface Impoundment/Oily  Surface
    at Shell Oil Company in Wood River, IL	  3-15

 6  Cross Referenced List of Submitted Samples Collected at Shell Oil,
    Wood River, IL	  3-16

 7  Quality Control Date for Analyses Conducted on the Samples  Collected
    at Shell Oil in Wood River, IL: Surrogate Recoveries -
    Volatile Organics	  3-17
                                  3-3

-------
                                LIST OF FIGURES


Figure                                                                   Page

 1  Facility layout for Shell Oil, Wood River, IL	 3-6

 2  Wastewater treatment process flow for Shell Oil,
    Wood River, IL	 3-8
                                 3-4

-------
Facility:                     Shell Oil Company
                              Wood River Manufacturing Complex
                              P.O. Box 262
                              Wood River, Illinois  62095
FCID:                         ILD080012305
Site Contacts:                Joseph N. Brewster, Process Engineer, Manager
                              Gina Pruitt, Process Engineer
                              (618) 254-7371
Field Trip Personnel:         Andrew Baldwin, GCA/Engineering
                              James Thomas, GCA/Measurements
                              Richard Roat, GCA/Measurements
                              Charles Vaught, GCA/Engineering
                              Joseph Brewster, Shell
                              Gina Pruitt, Shell
Visit Time and Date:          1:00 p.m., November 15, 1984
I.   INTRODUCTION

     Shell Oil Company, located in Wood River, Illinois, is the largest oil
refinery in the state.  Products manufactured by the company include
lubricants and asphalts, as well as gasoline and turbine fuel.  Most crude
oils arrive by pipeline and are refined via distillation, cracking, and
separation processes.  Shell Oil has been in operation since 1917, and employs
about 1750 workers.  The general facility layout is shown in Figure 1.
     Storage of refinery products is one of the primary operations at Shell.
Emissions have been estimated in the most recent State Implementation Plan
(SIP) at 20,000 kilograms per day of nonmethane volatile organics.  This
estimate includes emissions from fugitive sources.
     Climatic conditions the day of the visit were sunny skies, an ambient air
temperature of 45°F, and northwesterly winds of 25 to 30 mph.

II.  WASTESTREAM CHARACTERIZATION INFORMATION

     Process wastewater (5,000 gpm) is treated to remove waste oil sludges and
solids.  The water softening process removes approximately 40,000 pounds per
day of calcium carbonate.  Water softening is used to treat raw well water for
use in the refinery.
                                 3-5

-------
V
Oi
 MISSISSIPPI
    RIVER
	I
                            AMOCO
                          PETROLEUM
                          ADDITIVES
                           COMPANY
                               WEST PROPERTY
RESIDENTIAL
   AREA
                                                      NORTH
                                                      PROPERTY
                                                                     PRODUCT
                                                                   TANK STORAGE
                                                                                        15 ACRE SOLID WASTE
                                                                                         DISPOSAL BASIN
                              Ml I  I I  I  I I  I  I  I  I I I  I  I  'I I  I
                                            WASTEWATER
                                          TREATMENT  AREA
                          I I I  I  I +-J-
                       SEPARATOR


                     REFINERY OPERATIONS


                                     MAIN PROPERTY
                                                 .  PRODUCT
                                                TANK STORAGE
                                                          SOUTHWEST
                                                          PROPERTY
                                      RESIDENTIAL
                                        AREA
                                                                                      SCALE:   1" - 2,000'
                  Figure 1.   Facility  layout  for  Shell  Oil, Wood River,  Illinois.

-------
     Solids and semi-solid wastes are stored in a 15-acre solid waste disposal
basin.  These wastes include dissolved air floatation (DAF) float, slop oil
emulsion solids, and API separator sludge.  Waste quantities are provided in
the Part A Profile in Appendix E.

III. FACILITY PROCESS DESCRIPTIONS

     The wastewater treatment system at Shell, shown in Figure 2, is typical
of those found at many refinery operations.  First, oils and water are
separated via API separator.  The liquid is then combined with sanitary sewage
wastewater and lime solids from process cooling water and boiler water
softening.  Further removal of floats and solids is accomplished in the
dissolved air floatation unit.  The liquid is then allowed to equalize in
pond 1, bio-treated in a trickling filter, and is bio-treated in pond 2.
Bio-solids are removed in DAF 2 and returned to pond 2.  The fate of the final
effluent is the Mississippi River.
     Waste solids and sludges from API and DAF separations are allowed to
settle in a 15-acre disposal basin.  The major waste types in the basin are
listed in the Wastestream Characterization Information section.  An oil slick,
covering about 10 percent of the surface area of the basin, is periodically
drawn off by vacuum trucks and recycled to the refinery.  Solid calcium
carbonate deposits, extracted during water softening, occupy about 5 percent
of the water surface.  The rest of the surface area is open water.  Water
removed from the basin is routed back to the first API separator.
     Specific information necessary for estimating air emission release rates
from the waste disposal basin and bio-treatment pond 2 are given  in Table  1.

IV.  SAMPLING INFORMATION

Sample Location ..Description

     Two impoundments were sampled (Figure 2):
     o    biotreatment pond 2, and
     o    the solid waste basin
                                 3-7

-------
LJ

00
             REFINERY
             PROCESS
              UNITS
                         PROCESS
                         WASTEWATER
            OIL LAYER
            WITHDRAWN BY
            VACUUM TRUCKS
             POND  NO,I
           (EQUALIZATION)
                                   OILY
                                  WATER
        API
      SEPARATOR
   IS - ACRE SOLID
WASTE DISPOSAL BASIN
                                DAF NO.)
TRICKLING
 FILTER
          SAMPLING LOCATION
FLOAT
AND
SOLIDS
                      API
                    SEPARATOR
                         API
                       SEPARATOR
                                                                                   API SOLIDS
                                  SEWAGE
                                                                LIME
                                                                SOLIDS
                                                                                   WASTE BIO-SOLIDS
                                                                              BIO-SOLIDS RECYCLE
   POND NO.2
 (BIOTREATMENT)

& AM
                       DAF NO.2
                      (CLARIFIER)
SANITARY
  SEWER
                                                 COOLING AND
                                                 BOILER WATER
                                                LIME SOFTENING
POLISHING
 LAGOONS
                                                                                                                                f.OOOgpm
                                                                                                                          EFFLUENT TO
                                                                                                                       MISSISSIPPI RIVER
                       Figure  2.   Wastewater  treatment  process flow  for  Shell Oil,  Wood  River,  Illinois,

-------
    TABLE 1.  MODEL INPUT DATA FOR AIR EMISSION RELEASE RATE DETERMINATIONS
              AT SHELL OIL, WOOD RIVER, ILLINOIS.
_Spli
-------
 One  set  of quintuplicate  liquid  samples  (SOC-AP-1) was  taken  from
 bio-treatment  pond  2, an  aerated surface  impoundment where wastewater  is
 biologically treated  following equalization and  filtering.  No characteristic
 odors were noticeable.  Sample temperature was 28°C.
     Three sets  of  quintuplicate liquid samples  were taken from the  solid
 waste basin.   One sample  set  (SOC-SI-1) was taken at the influent  (35°C),
 another  (SOC-SI-2)  from a calm section of the basin (14°C), and the  final
 sample set (SOC-SI-3) from an oily area  (14°C).  A strong odor was noticeable
 in the vicinity  of  the basin.  Splits were provided for Shell for  all  samples
 taken.

 Quality^Assurance

     Sampling  procedures  were employed as described in  the Quality Assurance
 Project  plan dated  30 October 1984.  Liquid samples were collected in
 quintuplicate, as a standard procedure, with one of the five samples retained
 by the facility  as  a split.  The  remaining quadruplicate liquid samples were
 returned to the  GCA Analytical Laboratory in Bedford, MA, where they were
 received into  the sample  bank.
     Sample custody and handling  procedures included the use of sample tags,
 chain-of-custody sheets,  refrigeration of samples between sampling and
 analysis,  and  shipping of samples in coolers sealed with custody seals.  In
 addition,  each sample was assigned a unique sample code which linked it to the
 facility,  the  source, and the sample point.
     Some  of the sample matrices  and locations made it  difficult if not
 impossible to collect the liquid  samples without air bubbles forming in the
40 ml VOA vial.  In every case repeated attempts were made to obtain the
highest quality  samples.
                                   3-10

-------
V.   SAMPLE ANALYSIS

Analytical, Summary

     Tables 2 through 5 provide the analytical summary reports for all of the
process samples collected during the site visit (see Appendix A).  These
tables present the major compounds quantified by either GC/MS (GCA
Corporation/Technology Division) or a multiple detection system (Radian
Corporation).  The actual data report sheets for each respective sample are
provided in Appendix B and Appendix C.
     Aqueous and oil samples obtained at Shell were analyzed as indicated in
Appendix D.

Quality.. Assurance

Chain of Custody

     A set of samples was received by GCA/Technology Division on November 19,
1984, for volatile organic analysis (VGA).  Routine inspection upon receipt
revealed the samples to be clearly labeled and appropriately chilled.  Air
bubbles were observed in some samples; these are noted in Table 6 under
remarks.  Upon receipt the submitted samples were entered in the Master Log
Book and assigned GCA Control Numbers as listed in Table 6.  Chain of custody
procedures were followed and the samples were transferred to the locked Sample
Bank for refrigerated storage until the time of analysis.  Sample custody
records were maintained throughout all laboratory procedures.  Duplicate
samples were submitted to Radian Corporation of Austin, Texas, under chain of
custody for volatile organic analysis (VGA).

Quality Control

     Quality control protocol for volatile organics determination included the
use of surrogate spikes.  Each sample was spiked wih a surrogate mixture
containing dg-toluene, d^-l-Z-dichloroethane, and bromofluorobenzene; these
results are shown in Table 7.
                                   3-11

-------
                    TABLE 2.    LIQUID SAMPLE ANALYSIS FROrt THE BIOTREATHEST PGHO 12
                                AT SHELL OIL COnPANY IN HOOD RIVER,  ILLINOIS
Kajor Cccpcunds
1,2-Dichloropropane
2,2,5-Trisethylhexane
2,4,4-Trise-2-pentene
2,5-Bisethylhexane
Acetcne
B-Pinene
Butanone
Butyr aldehyde
Isoautvlbanzsne
Isebutyraliishyce
iscoentine
itethylsne chloride
N-Hexane
8-Pantane
N-l'ndecane
Toluene
TOTAL PARAFFINS
TOTAL OLEFlfiS
TOTAL ARDJ1ATIC HC
TOTAL HALQ6ENATED HC
TOTAL OXYGENATED HC
TOTAL UHIDENTIFIH HC

TOTAL NON-ffiTHAKE HC
c
Concentration lig/1)
a b
Analysis 1 Analysis 2
0.01
0.03
0.02
0.03
0.4 1.3
0.02
0.1
0.1
0.1
0.02
1.6
0.4 C.J
0.4-
0.1
0.01
0.5
2.6
0.05
0.6
0.3
1.5 •
2.6
d
2.6 3.5
.,.,_.. ..— — — 	 -_.-_..,._--,--.-.———————
0
Analysis oi saaple 41786 by SCA Corporation/Technology Division using SC/ilS.

Analysis of saiple 41734 by Radian Corporation using BC/ND.

iq/i = pps assuiin; a density of 1

Concsntration of Qxyqenatad HC not used in Total NHHC calculation.
                                                  3-12

-------
                    TABLE 3.    LIQUID SAMPLE ANALYSIS FROH THE SURFACE IMPOUNDMENT
                                INFLUENT AT SHELL OIL COMPANY IN HOOD  RIVER,  ILLINOIS
                                                Concentration iog/U
Major Coapcunds

1.1,1-Trichloroetriane
2,2,5-Triaethylhexane
2,4-Diaethylpentane
S-Hethylpentane
Acetone
Benzene
Cyclohexane
Ethane
Ethylbenzene
Isebutyraldehyde
Ischeptane
Iscpentane
Hethylcyclohexane
Methyl cyclopentane
Ksthyiene chloride
N-Decane
N-Hexane
Nechexane
Toluene
Total Xylenes
TOTAL PARAFFINS
TOTAL AROMATIC HC
TOTAL HALOEENATE3 HC
TOTAL OXYGENATED HC
TOTAL UNIDENTIFIED HC

TOTAL NQN-KETHANE HC
                                      Analysis  t
          fa
Analysis 2




1.6
2.5








0.9



6.3
2.4

	
11
0.9
1.6
29

42
0.1
0.1
0.1
0.3
5.5
1.7
0.1
0.06
0.2
0.6
0.1
2.5
0.1
1.5
0.5
0.1
1.5
0.2
2.1

0.9
12
5
I
6

d
19
b
d
Analysis of sa,iple 41789 by 6CA Corporation/Technology Division using GC/MS.

Analysis of sasple 417B9 by Raaian Corporation using GC/MO.

sg/1 = pp» assuming a density of 1.

Ccncentraticn of Oxygenated HC not used in Total NtthC calculation.
                                                   3-13

-------
                   TABLE 4.    LIQUID SA8PLE ANALYSIS FRQH THE SURFACE 1SPOUKDBEN7
                              AT SHELL OIL COMPANY IN WOOD RIVER. ILLINOIS

                                                                  c
                                              Concentration lag/1)
a
Major Cojpounds Analysis I
1-Butanol
1-Decene
1-Prapanol
1-Undecene
2,2,4-Triaethylpsntane
2,2,5-Triiethylhexane
2,3,5-Triiethylpentane
2,3-Oiiethylpentane
2,4-Oiiethylqentane
2,5-Diaethylhexane
3-Hethyl heptane
3-flethylpentane
Acetone . l.S
Benzene 4.3
Cyclohexane
Cyclepentsne
DifcroBocnierosetbane
Isoheptane
Bethyl cyclohexane
Wethylene chloride 0.9
H-Decane
N-Sonane
N-Octane
N-Undecane
T-4-Bethyl -2-pentene
Toluene l.S
Total lylenss 1.0
TOTAL PARAFFIHS
TOTAL QLEFINS
TOTAL ARQHATIC HC
TOTAL HALGSENATEiJ HC 6.8
TOTAL OXYGENATED HC
TOTAL UNIDENTIFIED HC 40

TOTAL !WN-«ETHANE HC 67
Analysis 2a
0.4
0.5

0.2

0.1

O.S


0.1
0.1

0.9
0.3
10
0.2
0.3
0.6
O.OS
0.1
0.3
0.1
0.1

0.6

34
0.7
1.4
O.S
0.4

d
58
b
1 2b
1.2

7.2
0.6
0.1
0.05
0.03
0.1
0.1
0.1
0.2


0.3

11
0.2

0.2

0.1


0.9
0.4
0.8

30
1.0
1.1
0.6
8.4

d
47
Analysis of sawie 41794 by SCA Corporation/Technology  Division using  6C/3S.

Analysis cf sa*ole 41792 !2 analyses)  by  Radian  Corporation  using  5C/hD.

sg/1 = ppa assuiinq a density of 1.

Concentration ot Oxygenated HC not used in  Total  fWHC calculation.
                                               3-14

-------
                    TABLE 5.     LIQUID  SAMPLE ANALYSIS FRQH THE SURFACE INPOUSDhENT/OILlf
                                SURFACE AREA AT SHELL OIL COMPANY IN HQOQ RIVER, ILLINOIS
                                                                         a,b
          Major Cospounds                             Concentration  leg/U
                   .                                          7
          Ethylbenzene                                       IB
          Hethylene chloride                                 16
          Toluene                                            47
          Total  xylenes                                      77
          TOTAL AROMATIC HC                                 150
          TOTAL HALDBENATED HC                               16
          TOTAL ^IDENTIFIED HC                            3fcOO

          TOTAL NON-METHANE HC                             3700
a
  Analysis of saaole 41796 by SCA Corporation/Technology Division  using  SC/MS.
b
  •g/1 - ppi assusing a density of I.
                                                   3-15

-------
         TABLE 6.  CROSS REFERENCED LIST OF SUBMITTED SAMPLES COLLECTED
                   AT SHELL OIL, WOOD RIVER, ILLINOIS.
Sample
Identification
SOC-AP-1A
SOC-AP-1B
SOC-AP-1C
SOC-AP-1D
SOOSI-1A
SOC-SI-1B
SOC-SI-1C
SOC-SI-1D
SOC-SI-2A
SOC-SI-2B
SOC-SI-2C
SOC-SI-2D
SOC-SI-3A
SOC-SI-3C
SOC-SI-3C
SOC-SI-3D
GCA
Control
41783
41784*
41785*
41786
41787
41788
41789*
41790*
41791
41792*
41793*
41794
41795
41796
41797*
41798*

Remarks
SAB
LAB
LAB
SAB
SAB
LAB
LAB
LAB
SAB
SAB
SAB
SAB




SAB -Small air bubble

LAB = Large air bubble

*Submitted to Radian Corporation, Austin, Texas.
                                  3-16

-------
          TABLE 7.  QUALITY CONTROL DATA FOR ANALYSES CONDUCTED ON THE
                    SAMPLES COLLECTED AT SHELL OIL IN WOOD RIVER, ILLINOIS:
                    SURROGATE RECOVERIES - VOLATILE ORGANICS
     Sample
Identification
    GCA        D8-
Control No.  Toluene
Bromofluorobenzene
    D4-l,2-
Dichloroethane

SOC-AP-1D 41786
SOC-SI-1B 41788
SOC-SI-2D 41794
SOC-SI-3B 41796
Method Blank 01/09/85
Method Blank 01/10/85
Method Blank 01/15/85
Laboratory Control Sample
93
96
95
104
88
87
83
79
81
117
117
133
114
62
80
77
81
89
96
123
91
105
124
106
  Average Percent Recovery        90

  Relative Standard Deviation (7.)  8
                                   98

                                   26
                             102

                              16
                                      3-17

-------
     Section 4.
Texaco,  Incorporated
     Salem, IL
      4-1

-------
                               TABLE OF CONTENTS


Section                                                                  Page


  I.     Introduction	 4-5

 II.     Was test ream Characterization Data	 4-6

III.     Facility Process Descriptions	 4-6
 IV.     Sampling Information...	 4-8
              Sample Location Description	 4-8
              Quality Assurance.	 4-8
  V.      Sample Analysis	 4-11
              Analytical Summary.	 4-11
              Quality Assurance	 4-14
                                     4-2

-------
                                 LIST OF TABLES
Table                                                                     Page

 1  Model Input Data for Air Emission Release Rate Determinations,
    Texaco, Salem, IL	  4-9

 2  Liquid Sample Analysis form the Bubble Pit at Texaco Inc.  in
    Salem, IL	  4-12

 3  Liquid Sample Analysis from the Settling Basin at Texaco Inc.
    in Salem, IL	  4-13

 4  Cross References List of Submitted Samples Collected at Texaco
    in Salem, IL	  4-15

 5  Quality Control Data for Analyses Conducted on the Samples
    Collected at Texaco in Salem, IL.  Surrogate Recoveries -
    Volatile Organics	  4-17
                                      4-3

-------
                                LIST OF FIGURES

Figures                                                                  Page

 1  Flow plan water flooding extraction operation at Texaco,
    Salem, IL	 4-7

 2  Sampling points at Texaco, Salem, IL	  4-10
                                     4-4

-------
Site:                   Texaco, Inc.
                        Route 2
                        Salem, Illinois  62881
Site Contact:           Gailon Gibb, Assistant Superintendent
                        Chris Culver, Engineer
                        (618) 548-1803
Field Trip Personnel:   Andrew Baldwin, GCA/Engineering
                        James Thomas, CCA/Measurements
                        Richard Roat, CCA/Measurements
                        Chuck Vaught, GCA/Engineering
                        Gailon Gibb, Texaco
                        Chris Culver, Texaco
                        John Hamby, Texaco
Visit Time and Date:    10:00 a.m., 11/14/84
I.  INTRODUCTION

    The Texaco facility in Salem, Illinois, is an oil production field.
Secondary oil extraction processes are currently in operation.  These involve
"flooding" the oil field with water via injection wells, withdrawing the
oil/water mixture, and separating the oil from the water.  Currently,
approximately 244,000 barrels (bbl) of oil/water mixture are withdrawn  from
360 wells each day, of which 4,000 bbl are oil.
    A problem unique to this field is the formation of barium sulfate due  to
the presence of barium and sulfate in two of the geologic formations which are
flooded.  When water from these two formations is mixed, barium sulfate is
generated, forming a thick, rock-like layer on pipes and in lagoons.  For  this
reason, a large settling pond was constructed to allow settling of barium
sulfate.
    A wastewater treatment plant removes solids and minerals prior to
reinjection to prevent clogging of the formations.  Two hundred forty-five
water injection wells are currently in operation.
    The size of the field is approximately 8,800 acres, about 2.5 miles wide
and 6.5 miles long.  Residences are interspersed throughout the field.
Climatological conditions on the day of the visit were hazy skies, air
temperature about 45°F, and southerly winds about 10 mph.
                                   4-5

-------
 II.  WASTESTREAM CHARACTERIZATION DATA

     No listed hazardous  waste is generated  by  this facility.   No effluent  is
 produced because all treated process  water  is  reinjected into the oil  field
 wells.  Waste that is removed in the  settling  pond includes excess crude oil
 and  barium sulfate.   Approximately 10.08 million gallons of waste are  handled
 each day in this system.   No specific waste characterization  was available.

 III.   FACILITY PROCESS DESCRIPTIONS

     The  basic process flow is shown in  Figure  1.   The  oil/water  mixture is
 withdrawn from 360 wells  throughout the field.   From there it is pumped to one
 of two oil/water separation systems designated  as the  north and  south
 batteries.   Each battery  has six 400-bbl free water knockout  (FWKO) tanks, two
 400-bbl  "gun barrels," and two 400-bbl  stock tanks.
     In the  FWKO tanks, oil and water  are separated by  gravity, after which the
 oil  layer is drawn off.   This oil is  pumped to  the gun barrels,  where
 additional  oil/water separation takes place.  The oil  then goes  to the two
 stock  (storage)  tanks, which are connected  to a "sales line"  that eventually
 reaches  a refinery.
    Prior to installation of the two  400-bbl stock tanks, a single 3,000-bbl
 tank was  used.   Because this tank had a longer  residence time, tank botttom
 solids had  to be  removed  periodically and disposed in  a nearby earthen pit.
 Illinois  State regulations  recently required the  closing and  filling of such
 pits,  hence  Texaco switched to smaller  stock tanks.  The pit  was still open at
 the time  of  visit to allow material in  it to dry,  but  company officials noted
 that it has  been  inactive for at least  a year.
    The water from the FWKO tanks  is  pumped  to  a  bubbling chamber,  to  drive
 off hydrogen sulfide gas.   From there the water is pumped to  the barium
 sulfate/oil  skim  pond, allowing for the removal of oil (not a substantial
 quantity) as  well  as  the  settling  of  barium sulfate.   Following  the skim pond,
water  is  pumped to a cement  lined  pond  where fresh groundwater is added to
 supplement evaporative losses.   The water is then flocculated and filtered as
                                4-6

-------
                       PRODUCING
                         WELLS
                       (CURRENTLY
                         360 IN
                       OPERATION)
              WATER
•vl
            (CURRENTLY
         2^0.000 bbl/day)
                                                     OIL
                                                     (CURRENTLY
                                                     *lOOO bbl/day)
BARIUM SULFATE/
 OIL SKIM POND
                                              GUN BARREL
                                                TANKS
                            FRESHWATER
                            (FROM RANNEY
                            COLLECTOR)
 CEMENT  POND
 (STORAGE AND
  FRESHWATER
  MIX-IN)
                                              STOCK TANKS
                                              SALES LINE
                                            DISTRIBUTION
                                                                   HIGH PRESSURE
                                                                   INJECTION WELL
                                                                      SYSTEM
                                                                    (245 WELLS)
                                                    WASTEWATER
                                                    TREATMENT
                                                (FLOCCULATION AND
                                                   FILTRATION)
                                    Figure 1.
Flow  plan—water flooding extraction
operation at  Texaco,  Salem,  Illinois.
 SLUDGE  TO
 LANDFILL

-------
 a final treatment step to remove  iron,  barium sulfate,  and  other inorganic
 solids.  Filtered backwash is  pumped  back to  the  barium sulfate  settling
 pond.   Final  effluent  is  then  injected  back into  the  same formations  from
 which  it came,  closing the cycle.
     Operating parameters  for the  bubbling pit  and for the settling pond are
 provided in Table 1.   The bubbling  pit  is actually a  tank,  while the  settling
 pond in an impoundment.

 IV.  SAMPLING  INFORMATION

 Sample  Location Description

     The bubbling pit is the first process step where  volatiles are exposed to
 the  atmosphere.   One quadruplicate  liquid sample  (TI-BP-1)  was obtained near
 the  effluent  discharge of the  bubbling  pit (Figure 2).   Due to the highly
 aerated condition of the  pit,  samples contained some  air bubbles.  Sample
 temperature was  32°C.
     Another quadruplicate liquid sample (TI-SB-1)  was taken from the  settling
 pond (Figure  2).   Sampling was performed  from  the catwalk of the oil  skimmer,
 where the sample  was taken from an  oil  slick on the pond surface.  Sample
 temperature was  28°C.

 Qua 1 i ty_As surance

     Sampling  procedures were employed as  directed  in  the Quality Assurance
 Project Plan  dated 30  October  1984.  Liquid samples were collected in
 quadruplicate.  The facility did not request a split.   The  quadruplicate
 liquid  samples were returned to the GCA Analytical Laboratory in Bedford, MA
where they were received  into  the sample  bank.
     Sample custody and handling procedures included the  use  of sample tags,
chain-of-custody  sheets,  refrigeration  of samples  between sampling and
analysis, and shipping of  samples in coolers sealed with custody seals. In
addition, each sample was  assigned a unique sample code  which linked  it to the
 facility, the source, and  the sample point.
                                    4-8

-------
    TABLE 1.  MODEL INPUT DATA FOR AIR EMISSION RELEASE RATE DETERMINATIONS,
              TEXACO, SALEM, ILLINOIS.
Bubbling Pit
  Type:
  Aeration type:
  Operation:
  Typical throughput:
  Typical retention time:3
  Dimensions:
  Operational surface area:
  Operational depth:
  Number of blowers:
  Blower output:
  Diffusion system:
Settling Pond
  Type:
  Operation:
  Typical throughput:
  Typical retention time:3
  Dimensions:
  Operational surface area:
  Average operational depth:
  Approximate area of oil slick:
Aerated tank
Diffused air
Continuous flow
10,080,000 gpd (240,000 bbl/day)
Approximately 15 minutes
20 ft by 40 ft by 20 ft deep
800 ft2
18.5 ft
3 (two operational at a time)
4,600 standard ft3/min (two blowers)
Piping from blowers (uniform diffusion)
Nonaerated impoundment
Continuous flow
10,080,000 gpd (240,000 bbl/day)
13 hrs
1,200 ft by 300 ft by 0-8 ft deep
360,000 ft2
2 ft
1,000 ft2
  Based on reported throughput and tank dimensions.
                                  4-9

-------
H
O


BUBBLE
PIT
LIME SOLUTION



SAND SOLUTION

®BP-1








V




R
o
A
D



















p
SB-1®

ii

k^_




'
/
'
^
;
/
£
OIL
SKIMMER









/ CAT
' WALK
DISCHARGE
PIPES SETTLING BASIN {SKIM POND)
                                                                                NOTE:NOT TO  SCALE

                                                                                ® SAMPLE  POINT
                               Figure 2.   Sampling points at Texaco, Salem, Illinois.

-------
    Some of the sample matrices and locations made it difficult if not
impossible to collect the liquid samples without air bubbles forming in the
40 ml VGA vial. In every case repeated attempts were made to obtain the
highest quality samples.
V.  SAMPLE ANALYSIS

Analytical Summary

    Tables 2 and 3 provide the analytical summary reports for all of the
process samples collected during the site visit (see Appendix A).  These
tables present the major compounds quantified by either GO/MS (GCA
Corporation/Technology Division) or a multiple detection system (Radian
Corporation).  The actual data report sheets for each respective sample are
provided in Appendix 8 and Appendix C.
    Analytical procedures are outlined in Appendix D.  Aqueous and oil samples
were obtained at Texaco.
                                   4-11

-------
                    TABLE 2.    LISUIG SASPLE A5SLYSI5 FfiW THE BUBBLE PIT AT
                                TE2ACD INCORPORATED  18 SALES,  ILLINOIS
s= :===== — xsxsssssssesssssasssss=5=-~s=ss-—-assssss=sssss=~—
Concantraticn
a
Major Ceapsunds Analysis 1
1-Butanal
l-2scsne
i-Propansl
2.3-Disethylcap.tane
3-fcatnylhaxana
3-Kethylssntans
Acetone 0.4
Ssr.zans 1.0
Cycicaentane
UaJrosech! srasstnsne
Ethylbenzena
Ischestane
Ssrhylcyclchsxane
Satlivlane chlsrine 0.4
M-ricnane
JKJctana
M-Prcuyibsnisr.s
Prsayrse
Styrsre
T-*-SBinyl -2-psntins
Talasne 0.8
Total Ivlsnss 0.2
s-iylens/a-iyiens
TOTAL PflRAFFUIS
TOTAL OL-FL1S
TOTAL AROi-fiTIC HC 2.0
TOTAL HALSSSHATED HC
TGTSL OIYGSiATB HC
TOTAL IWI5ESTIFIE3 HC 2.9

T2TAL 3CS-STHANE HC 4.9
c
lsg/1)
b
Analysis 2
0.9
0.1
0.4
0.7
0.7
1.1

0.8
12.0
O.I
2.1
1.0
0.4

7.0
2.0
0.2
0.3
0.7
0.4
0.3

0.5
45
0.9
4.o
0.1
1.3
19.6
a
70
b
Analysis of isapie 41SCO by  3CA Carpcritian/Tacnnolagy Bivision  using  SC/BS.

Analysis sf ssaala 41201 by  Sasian  Corsoration  using SC/ftO.

og/'l = pss aisuaing a deasity OT 1.

Csr-cMtraiisn ot Oxyganatac  HC ns:  usad  ir.  Total  NhHC calculation.
                                                    4-12

-------
                   TABLE 3.    LIQUID SAMPLE ANALYSIS FRGN THE SETTLINS BASIN
                               AT  TEXACO  INCORPORATED IN SALEM, ILLINOIS
                                                                   a,b
          Rajor  Ccapounds                            Concentration  (sg/1)
          Benzene                                             6.
          Ethylbenzene                                        25
          Rethylene  chloride                                 41
          Toluene                                            19
          Total  xylsnes                                      SB
          TDTAL AROMATIC HC                                 110
          TOTAL HAL06ENATED HC                               41
          TOTAL IMIOENTIFIEO HC                            2600

          TOTAL JESJ-HETKASE HC                             2700

a
  Analysis of saapls 41604 by SCA Corporation/Technolcqy Division using SC/KS.
b
  eg/1 = ppa assuming a density of 1.
                                                   4-13

-------
Quality Assurance

Chain of Custody

    A set of samples was received by GCA/Technology Division on November 19,
1984 for volatile organic analysis (VGA).  Routine inspection upon receipt
revealed the samples to be clearly labeled and appropriately chilled.  Air
bubbles were observed in some samples; these are noted in Table 4 under
remarks.  Upon receipt the submitted samples were entered in the Master Log
Book and assigned GCA Control Numbers as listed in Table 4.  Chain of custody
procedures were followed and the samples were transferred to the locked Sample
Bank for refrigerated storage until the time of analysis.  Sample custody
records were maintained throughout all laboratory procedures.  Duplicate
samples were submitted to Radian Corporation of Austin, Texas under chain of
custody for volatile organic analysis (VGA).
                               4-14

-------
       TABLE 4.  CROSS REFERENCED LIST OF SUBMITTED SAMPLES COLLECTED AT
                  TEXACO IN SALEM, ILLINOIS.
Sample
Identification
TI-BP-1A
TI-BP-AB
TI-BP-1C
TI-BP-1D
TI-SB-1A
TI-SB-1B
TI-SB-1C
TI-SB-1D
GCA
Control
41799
41800
41801*
41802*
41803*
41804
41805*
41806

Remarks
SAB
LAB
LAB
LAB
SAB
SAB
SAB
SAB
SAB = Small air bubble

LAB = Large air bubble

*Submitted to Radian Corporation, Austin, Texas.
                                  4-15

-------
Quality Control

    Quality control procedures for the determination of volatile organics
included the use of surrogate spikes.  Each sample was spiked with a surrogate
mixture containing ds-toluene, bromofluorobenzene, and d4-l,2-dichloroethane.
Surrogate recoveries are presented in Table 5.
                                  4-16

-------
      TABLE 5.  QUALITY CONTROL DATA FOR ANALYSES CONDUCTED ON THE SAMPLES
                COLLECTED AT TEXACO IN SALEM, ILLINOIS.  SURROGATE RECOVERIES
                - VOLATILE ORGANICS
Sample
Identification
TI-BP-1B
TI-SB-1D
Method Blank
Method Blank
GCA
Control No.

41800
41806
01/09/85
01/15/85
Laboratory Control Sample
D8-
To luene

83
99
88
83
79
Bromof luorobenzene

110
74
114
80
77
D4-l,2-
Dichloroe thane

96
120
91
124
106
Average Percent Recovery              86

Relative Standard Deviation (%)        7.7
91
19
107
 14
                                4-17

-------
         APPENDIX A
SAMPLE IDENTIFICATION FORMS
     A-l

-------
                                                                        SAMPLE INVENTORY FOR MIOCO CHEMICAL  CORPORATION  III HOOD RIVER, ILLINOIS.
1DI
ILOC04272629
UD004272429
1LD004272429
ILD004272429
1LC004272429
1LB004272429
ILIIO(I4272429
1LCQ04272429
ILD004272429
1LD004272429
1LC004272429
1LM04272429
1LD004272429
1LD006272429
ILD004272429
ILD004272429
ILD004272429
11D004272429
1LD004272429
ILD004272429
ILD004272429
1LD004272429
SITE
Aioco Chiiicil Corp.
Aioco Chiiicil Corp,
Aioco Chiiicil Corp.
Aioco Chiiicil Corp.
Aioco Chiiicil Corp,
AJOCO Cheiicil Corp.
Aioco Cheiicil Corp.
Aioco Chiiicil Corp.
Aioco Chiiicil Corp.
Aioco Chiiicil Corp.
Aioco Chiiicil Corp.
Aioco Chiiicil Corp,
Aioco Chiiicil Corp.
Aioco Chiiicil Corp.
Aioco Cheiicil Corp,
Aioco Chiiicil Corp.
Aioco Chiiicil Corp,
Aioco Chiiicil Corp,
Aioco Cheiicil Corp,
Aioco Chiiicil Corp.
Aioco Chiiicil Corp.
Aioco Cheiicil Corp.
SOURCE
Sludgi Ligoon
Sludgi Ligoon
Sludgi Ligoon
Sludgi ligoon
Sludgi Ligoon
Sludgi tigoon
Sludgi Ligoon
Sludgt Ligoon
Sludgi Ligoon
Eludgi Ligoon
Sludgi Ligoon
Sludgi Ligoon
Spriy Pond
Spriy Pond
Spriy Pond
Spriy Pond
Epny Pond
Spriy Pond
Spriy Pond
Spriy Pond
Sludgi Ligoon
Sludgi Ligoon
COHHCNTS
Clur Liquid Phut
Clur Liquid Phut
Clur Liquid Phiu
Clur Liquid Phm
Oil Slick
Oil Slick
Oil Slick
Oil Slick














SAMPLE
IDI
ACC-OM-IA
ACC-ON-IB
ACC-OIMC
ACC-OIH0
ACC-OhS-IA
ACC-OHS-IB
ACC-ONS-IC
ACC-ONS-ID
ACC-SL-IA
ACC-SL-IB
ACC-SL-1C
ACC-9L-1D
ACC-SP-IA
ACC-SP-IB
ACC-SP-IC
ACC-SP-ID
ACC-SP-2A
ACC-EP-2B
ACC-SP-2C
ACC-9P-2B
ACC-SL-CI
ACC-SL-M
SAMPLE LAB
TYPE CONTROL 1
Liquid
Liquid
Liquid
Liquid
Liquid
Liquid
Liquid
Liquid
Liquid
Liquid
Liquid
Liquid
Liquid
Liquid
Liquid
Liquid
Liquid
Liquid
Liquid
Liquid
Soil Con
Boil Cori
41731
41732
41733
41734
41733
41734
41737
4I7SB
41739
41740
41711
41742
41763
41744
41743
41744
41747
41748
41749
41770
41814
41813
DATE SAHPLIKB DATE DATE ANALYSIS DATE
SAHPLED CONTRACTOR RECEIVED ANALYZED CONTRACTOR REPORTED
11/I3/B4
11/13/84
11/13/84
11/13/84
11/13/84
11/13/84
11/13/84
11/13/84
11/13/84
11/13/84
11/13/84
1I/13/B4
11/13/84
11/15/84
11/13/84
11/13/84
11/13/84
11/13/84
11/13/84
11/13/84
11/13/84
11/13/84
BCA
BCA
BCA
BCA
BCA
ECA
BCA
BCA
BCA
BCA
BCA
6CA
BCA
BCA
ECU
BCA
BCA
ECA
BCA
BCA
BCA
BCA
11/19/84 NA
11/19/64 NA
11/19/84 12/05/84
11/19/84 01/11/83
11/19/84 NA
11/19/84 12/04/84
11/19/84 01/13/83
11/27/84 NA
11/19/84 12/05/84
1 1/27/84 NA
11/19/84 01/10/83
11/27/94 NA
11/19/84 I2/03/B4
11/27/84 OI/22/B3
11/27/84 NA
11/19/84 OI/09/B3
11/27/84 01/22/81
11/19/84 I2/03/B4
11/19/84 01/10/85
11/27/84 NA
11/19/84 02/2I/B3
11/27/84 01/01/83
RAD
RAD
BCA
GCA
RAO
BCA
BCA
RAD
BCA
RAD
BCA
RAD
ECA
RAD
RAD
BCA
RAD
ECA
BCA
RAD
BCA
RAO


OI/09/B3
02/12/83

DT
02/I2/B3

01/01/81

4I/2B/8S

01/09/83
02/28/83

OI/2B/B3
02/2B/B3
OI/C9/B3
OI/2B/B3

03/2B/B3
02/03/83
NA > not inilynd

-------
uo
                                                                                    SAHPLE INVENTORY FDR REILLY TAR t CHEMICAL IN 6RANITE CITY, ILLINOIS.
FACILITY
IDI
ILM04278340
RDOC427B340
1111004278340
lU0042763iO
1LD004278340
iwtotnmo
ILD004278340
1LD00427BM
11DOC627BIW
1LDC01279340
HD004278340
ILD0042763fcO
SI
Reilly Tir
Reilly Tir
Reilly Tir
Reilly Tar
Reilly Tir
Rfilly Tir
Reilly Tir
Reilly Tir
Reilly Tir
Reilly Tir
Reilly Tir
Rtllly Tir
FE
Chuicil
Chtiicil
ChttlcJl
ChHlcil
Chuicil
Chiilcil
Chuicil
Cheiicil
Cheiicil
Chtiicil
Cheiicil
Chuicil
SOURCE
Liiching Fiild
Ltiching FiiU
Ltiching Field
LiicMng Fitld
Ligoon
Ligoon
Ligoon
Ligoon
Ligoan
ligoon
Ligoon
Ligoon
COHNENTS




Fony, Aeritid Am
Foiiy, Aerited Am
Fony, Aerittd Am
Fony, Aeritid Arei
Cili Arei
Cili Am
CiU Arei
Cili Arei
SAMPLE
IB 1
RTC-F-IA
RTC-F-IB
RTC-F-IC
RTC-F-U
RTC-L-IA
RTC-L-IB
RTC-L-IC
RTC-L-IB
RTC-L-2A
RTC-L-2B
RTC-L-2C
RTC-L-2D
SAMPLE
TYPE
Liquid
Liquid
Liquid
Liquid
Liquid
Liquid
Liquid
Liquid
Liquid
Liquid
Liquid
Liquid
LAB
CONTROL 1
41771
41772
4I77I
41774
41775
41774
41777
4I77B
41779
41760
41761
41762
DATE
SAMPLED C
I1/14/B4
11/14/84
11/14/84
11/14/84
11/14/84
11/14/84
11/14/84
11/14/84
11/14/84
11/14/84
11/14/84
11/14/84
SAKPLINB
ONTRACTO
BCA
ECA
BCA
ECA
BCA
6CA
ECA
BCA
BCA
ECA
BCA
BCA
DATE
) RECEIVED
II/H/B4
11/11/84
11/27/64
11/27/64
11/27/64
11/19/64
11/19/84
11/27/84
II/27/B4
11/27/64
11/19/64
11/19/84
DATE
ANALY2ED C
12/04/84
01/10/63
01/22/6S
NA
OI/22/B5
12/04/64
01/10/85
NA
01/22/85
NA
12/04/84
01/09/65
INALYSU
1NTRACTO
ECA
ECA
RAD
RAD
RAD
6CA
BCA
RAD
RAD
RAD
ECA
ECA
DATE
R REPORTED
OI/09/6S
OI/2B/85
02/28/85

02/26/65
OI/09/B5
OI/2B/65

02/26/65

01/09/65
01/23/65
        M • not inilyzed

-------
r
                                                                                  SAMPLE INVENTOR* FOR SHELL OIL COMPANY IX HMD RIVER, ILLINOIS.
FACILITY
101
ILD00427B340
KD006278310
1LD00427B140
ILDOOi27BUA
UD004276I40
1LD00427B340
110004276340
H500427E510
1LC004278360
Ilt00427SJ«
ILD30627B340
1LD00427B340
111)006278:40
ILD00427B340
ILC004278360
1LD004276340
SITE
Ehill Oil Coipiny
Shill Oil Coipiny
Shill Oil Coipiny
Shill Oil Coipiny
Shill Oil Coipiny
Shill Oil Coipiny
Shill Oil Coipiny
Shill Oil Coipiny
Shill Oil Coipiny
Skill Oil Coipiny
Shill Oil Coipiny
Still I Oil Coipiny
Shill Oil Coipiny
Shill Oil Coipiny
Shill Oil Conpiny
Shill Oil Coipiny
SOURCE
Biotriitunt Pond 12
Biotriitunt Pond 12
Biotriitunt Pond 12
liotriitunt Pond 12
Surdci lipoundunt
Surdci lipoundunt
Surdci lipoundunt
Surdci Iipoundunt
Surdci lipoundunt
Surdtf Upoundunt
Eurdci lipoundunt
Surdci lipoundunt
Surdci lipoundunt
Surdci lipoundunt
Surdci lipoundunt
Surdci lipoundunt
COMMENTS




Influent
Influent
Inlluint
IMlutot




Oil Slick
Oil Slick
Oil Slick
Oil Slick
SAMPLE
ID 1
SOC-AP-IA
EDC-AP-1B
BOC-AP-IC
SDC-AP-ID
SOC-EI-1A
SOC-S1-U
SOC-61-IC
SDC-SI-ID
BOC-SI-2A
SOC-S1-28
SOC-SI-2C
SOC-S1-2B
SOC-SI-3A
SOC-S1-3B
SOC-6I-3C
SOC-SI-30
SAMPLE
TYPE
Liquid
Liquid
Liquid
Liquid
Liquid
Liquid
Liquid
Liquid
Liquid
liquid
Liquid
Liquid
Liquid
Liquid
Liquid
Liquid
LAB
CONTROL 1
41763
41784
41763
41784
4I7B7
4I7B8
4I7B9
41790
41791
41792
41793
41794
41795
4179ft
41797
41798
DATE
SAMPLED C
11/15/64
11/15/84
11/13/84
11/13/84
11/13/84
II/I3/B4
11/13/84
11/13/84
11/15/84
11/13/84
11/15/84
11/13/84
11/15/64
II/IS/B4
11/13/64
11/13/84
SAHPLIN6
ONTRACTOR
ECA
ECA
BCA
BCA
ECA
BCA
GCA
ECA
ECA
BCA
BCA
BCA
ECA
BCA
BCA
BCA
DATE
1 RECEIVED
I1/I9/B4
11/27/64
11/27/84
11/19/64
11/19/64
1I/I9/B4
11/27/64
11/27/64
11/19/84
11/27/84
11/27/84
11/19/84
11/19/64
11/19/84
11/27/64
11/27/64
DATE «
ANALY2ED U
12/06/64
01/22/83
NA
01/10/83
12/07/84
01/09/6S
01/22/85
NA
12/07/64
01/29/65
NA
01/09/85
NA
01/15/83
NA
NA
DIALYSIS
INTRACTD
ECA
RAD
RAD
BCA
BCA
ECA
RA1
RAD
ECA
RAD
RAD
ECA
ECA
ECA
RAD
RAD
DATE
R REPORTED
01/09/63
03/15/85

OI/2B/B3
01/09/85
05/28/85
01/15/65

01/09/B3
01/13/65

01/28/85

02/12/85


        NA > not  inilynd

-------
                                                                                        SAMPLE INVENTORY FOR TEIACO, INCORPORATED IN SOLED, ILLINOIS.
U1

Teuco
Teuco
Teuco
Teuco
Teuco
Teuco
Teiito
Tiiico
SITE
Incorporited
Incorporited
Incorporited
Incorporited
Incorporited
Incorporited
Incorporited
Incorporited
SOURCE
Bubble Pit
Bubble Pit
Bubbli Pit
Bubble Pit
Settling Bitin
Settling Bitin
Settling Bitin
Settling luin
BAHPLE
COKHENTS ID 1
TI-BP-IA
TI-BP-1D
TI-BP-1C
TI-BP-IO
TI-SB-1A
Tl-SB-IB
TI-SB-IC
Tl-SB-ID
BAHPLE
TVPE
Liquid
Liquid
Liquid
Liquid
Liquid
Liquid
Liquid
Liquid
LAB
CONTROL 1
4IW
41BOO
41801
4IB02
41B03
4IB04
4IB05
41B04
DATE
SAMPLED C
11/14/84
11/14/84
11/14/64
II/14/B4
11/14/84
11/14/64
11/14/84
11/14/64
5AHPLINB
ONTRAC16I
BCA
ECA
BCA
ECA
ECA
ECA
BCA
BCA
DATE
» RECEIVED
11/19/64
11/19/64
11/27/B4
11/27/64
11/27/64
II/I9/B4
11/27/64
11/19/84
DATE 1
ANALYZED Cl
12/07/64
01/09/85
01/29/B3
NA
NA
NA
NA
01/13/65
INALVSIS
1NTRACTO
BCA
BCA
RAD
RAD
RAO
SCA
RAD
ECA
DATE
IR REPORTED
01/09/65
01/26/65
03/15/65




02/12/8!
                 NA • not inilyied

-------
      APPENDIX B
GCA DATA REPORT FORMS
     B-l

-------
Project
            1-623-027
                                          CCA Control No.
                                                             41754
                              DATA REPORT SHEETS

                                  Purgeables
Sample I.D.

Sample Matrix Water
                         Instrument
                                        Analysis Date ..1/11/85 ______

                                       5985^00 /MS, Sample Dilution _1;5,PT
Parameter
Chlororaethane
Bromome thane
Vinyl chloride
Chloroethane
Methylene chloride
Acetone
Carbon disulfide
1 , 1-Dichloroethene
1 . 1-Dichloroethane
Trans-l,2-dichloroethene
Chloroform
2-Butanone
1,1, 1-Trichlorot thane _
Carbon tetrachloride
Bromodichloronethane
Total xvlenes
Concentration
(ug/1)
NT)*
NO
NO*
ND
NO**
ND**
ND
ND
ND
ND-.''
34K
ND
ND
ND
ND
ND
Parameter
1,1^2,2-Tytrachlcroethane
1 ,2-Di.chloroprooare
Trans- 1 ,3-DichloroDropen§
T rich loroet hens
Dibrotnochlprome thane
Benzene
cis-l,3-Dichlorccrooene
2-Chloroethvl vinvl ether
Broiaoform
4-Methvl-2-oentat;oTie
Tetrachloroethene
Toluene
Chlorobenzene
Ethylbenzcne
Styrene

Concentration
(ug/1)
ND
ND
ND
ND
ND
ND
ND
ND*
1 ND
f -ND*
ND
ND
ND
ND
ND

PT s Purge and Trap
DI = Direct Injection
ND
ND*
     < 50 ug/1
      < 100 ug/1
     = blank contamination was  observed  for  this compound
ug/1 = ppb (for  density  of water  »  1)
K = Quantitation below detection  limit
                                      B-2
                                                  ©DA
                                                  GCA
                                                           ..-
                                                           Technology Division

-------
Project
        1-628-037
GCA Control No.
                               DATA REPORT SHEET

                             Qualitative Compounds*
Sample I.D.   ACC-OM-3D
                                  Analysis Date
                                                     1/11/85
Sample Matrix _Water ^^  Instrument  HP 5985 GC/HS  Sample Dilution  1:5 ?T
Parameter
Allyl Alcohol 	
Bis(chloromethvl)ether
Cvclohexane_ T _ r ~ .
Cvclohexanone
1,2-Dibromoethane
Dichlo rod ifluorome thane
Diethyl_etherTT,_ 	 .._.
Ethyl acetate
Ethvl acrvlate



Concentration
(Mg/D
NA
NU
ND
ND
ND
ND
ND
ND
JNA



Parameter
Furfural _^_ ^ 	 n._<_^ 	 ^ 	
IsobutYl alcohol .
Methyl acetate
Methyl alcohol
Methyl rcethacrylate
n-Butyl alcohol
n-Propyl benzene
Tetrahydrofuran
Trichlorof luoromethane
1,,1,2-Trichloro-
1,,2,,2-tfrifluoroethane
Trifluoroethane
Concentration
(ug/D
ND
NA
ND
NA
ND
NA
ND
ND
ND

ND
ND
^Concentration based on a comparison of the total ion area of the compound with
  that of  the internal standard.

NA « Not  analyzed by purge and trap

PT * Purge and Trap
DI * Direct Injection
 ND
< 50  ug/1
 ug/1  =  ppb  (for density of water =  1)
                                         B-3
                                                        GCA COPPOflAPCN
                                                   '.^  Technology Division
                                              GCA

-------
Project
1-628-037
GCA Control No.  41757
                               DATA REPORT  SHEETS

                                   Purgeables
Sample I.D. _ ACC-J3MS-1J^
                             Analysis Date _l/15/85_
Sample Matrix   Oil   (PEG)lnstrument   HP  5985  CC/MS   Sample  Dilution  1:500 FT
Parameter
Chlorome thane
Bromomethane
Vinyl chloride
Chloroethane
Methylene chloride
Acetone
Carbon disulfide
1 , 1-Dichloroethene
1 , 1-Dichloroethane
Trans-1 ,2-dichloroethene
Chloroform
2-Butanone
1 . 1 , 1-Trichloroethane
Carbon tetrachloride
Bromodichloromethane
Total xvlenes
Concentration
(yg/1)
ND*
ND
ND*
ND
27400*
ND
ND
ND
ND
ND-'
ND
ND
ND
ND
ND
ND
Parameter
1 , 1 ,2 ,2-Tetrachloroethane
1 , 2-Dichloropropane
Trans-l^S-Dichloropropene
Trichloroethene
Dibromochlorome thane
Benzene
c is-1 , 3-Dichloropropene
2-Chloroethvl vinvl ether
Bronioform
4-Methvl-2-pent2none
Tetrachloroethtjne
Toluene
Chlorobenzene
Ethvlbenzene
Stvrene

Concentration
(ug/1)
ND
ND
ND
ND
ND
ND
ND
ND*
ND
1 ND*
ND
ND
ND
ND
ND

PT = Purge and Trap
DI = Direct Injection

ND = < 5000 jig/1
ND* - < 10000 ug/1

ug/1 = ppb (for density  of water  =  1)
K = Quantitation below detection  limit

* = corrected for blank value
                                         B-4
                                       ~^^r -^^ •^••v
                                       GCA
                                                             GCA cCRPORAncr:
                                                             Technology Division

-------
Project
        1-628-037
GCA Control No.  41757
                               DATA REPORT SHEET

                             Qualitative Compounds*
Sample I.D. .  ACC-QMS-1 C
                                   Analysis Date.-^.1/1.5/_85.
Sample Matrix   Oil  (PEG) Instrument  HP 5985 GC/MS  Sample Dilution  1:50.0 FT
Parameter
Allvl Alcohol 	
BisCchloromethyDether
Cvclohexane
(^yclohexanone
1,2-Dibromoethane
Dichiorodifluorome thane
Diethvl ether 	
Ethyl acetate 	
Ethyl acrylate



Concentration
(yg/l)
NA
ND
ND
NA
ND
ND
ND
ND
NA
-f '


Parameter
Furfural
Isobutyl alcohol
Concentration
(ug/D
ND
NA
Methyl acetate 1 ra
Methyl alcohol
Methyl methacrylate
n-Butyl alcohol
n-Propyl benzene
Tetrahydrofuran
NA
ND
NA
ND
ND
Trichlorof luoromethane ' ND
1.1.2-Trichloro-
1,,2,,2-trif luoroethane
Trifluoroethane
ND
ND
^Concentration based on a comparison  of  the  total  ion area of the compound with
 that of the internal standard.

NA = Not analyzed by purge and  trap  ; see FID results

PT - Purge and Trap
DI = Direct Injection
ND
< 5000 ug/1
ug/1 = ppb  (for density  of  water = 1)
                                         B-5
                                                    GCA
                                                             GCA
                                                             Technology Division

-------
Project
1-628-037
Sample I.D.
             GCA Control  No.   41757	
                            (Matrix Spike)"

 DATA REPORT SHEETS

     Purgeables


	Analysis  Date  _J./15/85;	
Sample Matrix ,011  (PEG) Instrument  HP 5985 GC/MS  Sample Dilution 1:500 PT
Parameter
Chloromethane
Bromome thane
Vinyl chloride
Chloroethane
Methylene chloride
Acetone
Carbon disulfide
1,1-Dichloroethene
1 , 1-Dichloroethane
Trans-1 ,2-dichloroethene
Chloroform
2-Butanone
1,1, 1-Trichloroethane
Carbon ^tetrachloride
Bromodichloromethane
Total xylenes
Concentration
(ug/1)
NO*
ND
ND*
ND
41550*
6635*
ND
ND
ND
ND-'
ND
ND
ND
ND
ND
ND
Parameter
1,1,2, 2-Tetrachloroethane
1 ,2-Dichloropropane
Trans-1 ,3-Dichloropropene
Trichloroethene
Dibromochloromethane
Benzene
cis—1 ,3-Dichloropropene
2-Chloroethyl vinvl ether
Bromoform
4-Methvl-2-pentanone
Tetrachloroethene
Toluene
Chlorobenzene
Ethylbenzene
Styrene

Concentration
(ug/1)
ND
ND
ND
ND
ND
ND
ND
ND*
ND
ND*
ND
ND
ND
ND
ND

PT « Purge and Trap
DI = Direct Injection

ND = < 5000 ug/1
ND* = < 10000 ug/1

uy/1 = ppb (for density of water =  1)
K = Quantitation below detection limit

* = corrected for blank value
                                        B-6
                                                   GCA
                                                GCA CQRFORAriOM
                                                Technology Division

-------
Project
1-628-037
GCA Control No._*!7_5MMS)_
                               DATA REPORT SHEET

                             Qualitative Compounds*
Sample I.D. ^ACC-OMS-lC
                           Analysis Date  1/15/85
Sample Matrix   Oil  (PEG) Instrument  HP $985 GC/KS  Sample Dilution 1:50° PT
Parameter
Allvl^Alcohol 	
Bis(chlQromethyl}ether
Cyclohexane
$vc lohexanone
1,2-Dibromoethane 	
Dichlorodif luoromethane
Diethvl ether
Ethyl acetate^_ 	
EthvLacrYlate 	



Concentration
(Ug/1)
NA
ND
ND
NA
ND
ND
ND
ND
NA



Parameter
Furfural
Isobutvl alcohol
Methyl acetate
Methyl alcohol
Methyl methacrylate
n-Butyl alcohol
n-Propyl benzene
Tetrahydrofuran
Trichl
-------
Project
            1-628-037
GCA Control No. ,_4T757
                               DATA REPORT SHKKTS
                                   Purgeables
                                                              (Matrix Spike
                                                                  Duplicate)
                                         Analysis Date __1/_15/_S5_
Sample I.D. __ACCd2i!S=.LC	

Sample Matrix   Oil fprm Instrument  HP 5985 GC/MS. Sample Dilution  1:500 PT
Paraneter
Chlororaethane
Bronome thane
Vinyl chloride
Chloroethane
Methylene chloride
Acetone
Carbon disulfide
1 , 1-Dichloroethene
1 , 1-Dichloroethane
Trans-li2-dichloroethene
Chloroform
2-Butanone
1.1, 1-Trichloroethane
Carbon tetrachlcride
Broraod ich loromethane
Tocal xvlenes
Concentration
(ug/1)
'ND*
ND
ND*
ND
37050*
ND
ND
ND
ND
ND-'
ND
ND
ND
ND
ND
ND
Parameter
1 , 1 , 2 , 2-To t rach lo ro
-------
Project
1-623-037
GCA Control No. 41757 (MSP)
                               DATA REPORT SHEET


                             Qualitative Compounds*
Sample I.D. __ACC-QMS-1C
                           Analysis Date    1/15/85
Sample Matrix __Qil. (PEG) Instrument _HP..$985 GC/MS  Sample Dilution _1;50° PT
Parameter
Allvl Alcohol_
p is (chlorotngthyl) ether
Cvclohexane
Cvclohexanone
1,2-Dib^omoethane .
pichlorod if luorome thane
Diethvl ether
Ethyl acetaeerntm_^
Ethyl acrylaee_ _



Concentration
(ug/1)
NA
ND
ND
NA
ND
ND
ND
ND
NA
•


Parameter
Furfural
Isobutyl alcohol
Methyl acetate
Methyl alcohol
Methyl methacrvlate
n-Butyl alcohol
n— PTOPV! benzene
Tetrahydrofuran
Trich loro f luorqmechane
1.1.2-Trichloro-
1.2, 2-t;r if lueroethane
^Tri^luoroethane
Concentration
(pg/1)
ND
i^A
ND
NA
ND
NA
ND
ND
ND
ND
ND
^Concentration based on a comparison of the  total ion area of the compound with
 that of the  internal standard.


NA * Not analyzed by purge and  trap;  see  FID results


PT « Purge and Trap
DI * Direct Injection


ND = <  5000 ug/1
 ug/1 =  ppb  (for  density  of water  =  1)
                                          B-9
                                                    GCA
                                                             GCA CORPORATION
                                                             Technology Division

-------
Project    1-628-037
      GCA Control No.  41761
                            DATA REPORT SHEET: TSOF
                           Volatile Organic Compounds
 Sample Identification   ACC-SL-IC
 Analysis Date    1/10/85	
                                      Instrument and Sample Volume*
                                      HP 5935 GC/MS  1:5 FT	
 Sample Matrix 	Water
Finnigan OWA GC/MS_
PE 3920 GC/FID 	
HP 5890 GC/FID
Compound
Acetone
Acetonitrile
Allvl Alcohol
Aniline
Benzene
Bis (chloromethyl) ether
Bromodichlorome thane
Bromoform
Bromome thane
Carbon disulfide
Carbon tetrachloride
Chlorobenzene
Chloroethane
2-Chloroethvl viuyl ether
Chloroform
Chloromethane
C is-1 ,3-Dichloropropene
Cyclohexane
Cyclehexanone
Dibromochlorome thane
1 ,2-Dibromoethane
Dich lorod if luorozne thane
1 . 1-Dichoroethane
1 ,2-Dichloroethylenf!
1 , 1-Dichloroethylerrc
ij2-Dichioroorocj:n2
Diethvl ether
Ethyl acetate
Ethvl acrvlate
Ethylene
Concentration
(mg/1)
0.17
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND*
ND
ND*
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
Compound
Ethytene chloride
Ethvlene dibromide
Ethylene dichloride
Furfural
Isobutyl alcohol
Methyl acetate
Methyl alcohol
Methvl chloride
Methyl ethyl ketone
Methyl isobutvl ketone
Methyl methacrvlate
Methylene chloride
n-Butvl alcohol
n-Propyl benzene
Styrene
1,1,2,2-Tetrachloroethane
Tetrachloroethvlene
Tetrahydrofuran
Toluene
Trans l,3-Dichlorcr>rooene
1,1. 1-Trichlorcethar.e
Trichloroethvlsna
Trichlorof lt:oro^r»rh-in .-
1,1,2-Trichlorc-
-l,2.2-Trifluoronethar.ci
Trif luoroechane
Vinyl chloride
Xylenes


Concentration
(rag/1)
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND*
ND
0.19
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
I MD

ND
ND
ND~
MD '
1

*PT = Purge and Trap
 DI = Direct Injection
 HS = Headspace
ND =  <  0.05 rag/1
ND* = < 0.10 tag/1
                                          B-10
             GCA TECHNOLOGY DIVISION

-------
Pro ject_
1-628-037
CCA Control .No.	41761 (tnauri:-: spike)
                            DATA  REPORT  SH'.CLT:  TSDF
                           Volatile  Organic Compounds
 Sample Identification ACC-SL-IA
 Analysis Date   1/10/85	
 Sample Matrix 	Wat_er	
                                       Instrument  and Sample Volume*
                                       UP 5985 GC/MS 1:5 FT	
                           Finnigan OWA GC/MS.
                           PE  3920 GC/FTD
                           HP  5890 GC/FiD
Compound
Acetone
Acotonitrile
Allvl Alcohol
Aniline
Benzene
Bis(chloromethyl)ether
Bromodichlorome thane
Bromoform
Brombme thane
Carbon disulfide
Carbon tetrachloride
Chlorobenzene
Chloroethane
2-Chloroethyl vinvl ether
Chloroform
Chlorome thane
C is-1 ,3-Dichloropropcne
Cvclohexane
Cvclohexanone
Dibroraochloromethane
1 ,2-Dibromoethane
Dichlorodif luo rome t hane
1 , 1-Dichoroethane
1 ,2-Dichloroethylcne
1 , 1-Dichloroethvlene
1 ,2-Dichloroprooane
Diethvl ether
Ethvi acetate
Ethyl acrvlate
Ethvlene
Concentration
(mg/1)
0.17
NU
NO
Nn
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND*
ND
ND*
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
Compound
Ethylene chloride
Ethylene dibroraide
Ethvlene dichloride
Furfural
Isobutyl alcohol
Methvl acetate
Methyl alcohol
Methvl chloride
Methyl ethyl ketone
Methvl isobutvl ketone
Methyl methacrylate
Methvlene chloride
it-Butyl alcohol
n-Propyl benzene
Styrene
1,1,2,2-Tetrachloroethane
Tetrachloroethvlenu
Tet rahvdrof uran
To luene
Trans 1,3-Dichloropropene
I , I , l-Trichlorc-thane
Trichloroethvlene
Trichlorof luorom" thane
1,1,2-Trichloro-
-!,2,2-TrifluorcTetban2
Trif luoroethans
Vinvl chloride
Xvlenes
1
1
Concentration
(mg/1)
MD
ND
ND
ND
ND
ND
ND
ND
ND
ND*
ND
0.43
L ND
ND
ND
ND
ND
ND
ND
ND
1 ND
ND
t ND

ND
ND
ND*
NI)


 *FT = Purge and Trap
  DI = Direct Injection
  HS = Keadspace
  ND = < 0.05 rajj/l
  ND* = <- 0.10 ms/1
                                            B-ll
                                                     GCA  TECHNOLOGY DIVISION 3OA

-------
Project.
1-628-037
GCa Control No,
_417fil  (matrix spike-
        duplicate)
                            DATA REPORT SHEET: TSDF
                           Volatile Organic Compounds
 Sample Identification  ACC-SL-1A
 Analysis Date   1/10/85	
                                      Instrument and  Sample Volume*
                                      HP 5985 GC/MS   1:5 FT	
 Sample Matrix 	Water
                           Finnigan OWA GC/MS__
                           PE 3920 GC/FID 	
                           H? 5890 GC/FID	
Compound
Acetone
Acetonitrile
Allvl Alcohol
Aniline
Benzene
Bis(chloromethyl)ethor
Bromodichlorome thane
Bromoform
Bromotnethane
Carbon disulfide
Carbon tetrachloride
Chlorobenzene
Chloroethane
2-Chloroethvl vinvl ether
Chloroform
Chlorome thane
C is-1,3— DichlorooroDene
Cvclohexane
Cyclohexanone
Dibromochlorome thane
1 . 2-Dibromoethane
Dichlo rod if luorone thane
1 . 1-Dichoroethane
1 ,2-Dichloroethvlene
1 , 1-Dichloroethvlene
1 , 2-Dichlorooropane
Diethvl ether
Ethyl acetate
Ethvl acrvlate
Ethylene _
Concentration
(mg/1)
0.45
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND*
ND
ND*
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
Compound
Ethylene chloride
Ethylene dibromide
Ethylene dichloride
Furfural
Isobutyl alcohol
Methyl acetate
Methyl alcohol
Methyl chloride
Methyl ethyl ketone
Methyl isobutvl ketone
Methyl tnethacrvlate
Methylcne chloride
n- Butyl alcohol
n-Proovl benzene
Styrcnti
1,1,2,2-Tetrachloroethane
Tetrachloroethylene
Tet rally drofuran
To luene
Trans 1,3-Dichloroprooene
1.1. 1-Trichloroethane
Trichioroethvlene
Trichlorof luorome Chans
1,1,2-Trichioro-
-1,2, 2-Tr if luoromethane
Tr if luoroe thane
Vinvl chloride
Xylenes


Concentration
(mg/D
ND
ND
ND
ND
ND
ND
ND
ND
NE
ND*
ND
0.75
ND
ND
ND
ND
ND
ND
ND
ND
?ID
ND
xn

?ID
ND
OT*
::D


*PT = Purge and Trap
 DI = Direct Injection
 HS = lieadspace
 ND = < 0.05 mg/1
 ND* = < 0.10 mfi/1
                                        B-12
                                                    OCA  TECHNOLOGY DIVi:..QN

-------
Project_
1-62S-Q37
          Control No.
                            DATA RKPOUT SilKKT: TiiDF
                           Volatile Organic Compounds
 Sample Identification
 Analysis Date 	
              ACC-SP-1D
              1/9/85
                                      Instrument and Saaple Volune*
                                      HP 5985 GC/MS  1:5'PT	
 Sanple Matrix	Water
Finnigan OWA GC/MS_
PE 3920 GC/FID 	~
HP 5890 GC/FID	
Compound
Acetone
Acetonitrile
Allvl Alcohol
Aniline
Benzene
Bis(chloromethvl)ether
Bromodichloromethanp
Bromoform
Bromome thane
Carbon disulfide
Carbon tetrachloride
Chlorobenzene
Chloroethane
2-Chloroethyl vinyl ether
Chloroform
Chloroine thane
C is-l,3-Dichlorooropene
Cvclohexane
Cyclohexanone
Dibromochlorome thane
1 . 2-Dibrorcoethane-
D ichlorod if luoroase thane
1 , 1-Dichoroethane
1 ,2-Dichloroethylene
1 , 1-Dichloroethylene
1 ,2-Dichloropropune
Diethvl ether
Ethyl acetate
Ethyl acrvlate
Ethylene
Concentration
(rag/1)
0.15
ND
ND
ND
0.68
ND
ND
ND
ND
ND
ND
ND
ND
ND*
0.06
ND*
ND
ND
ND
ND
ND
ND
NU
ND
ND
ND
ND
ND
| ND
| ND
Compound
Ethvlene chloride
Ethylene dibromide
Ethylene dichloride
Furfural
Isobutyl alcohol
Methyl acetate
Methyl alcohol
Methyl chloride
Methyl ethvl ketone
Methyl isobutvl ketone
Methyl methacrylate
Methylene chloride
n-Butvl alcohol
n-Propyl benzene
Stvrene
1, 1,2,2-Tatrachloroethane
Tetrachloroethylene
Tetrahvdrofuran
Toluene
Trans 1,3-Dichloronropene
1,1, 1-Trichloroethane
Triehloroethvlen^
Trichlorof luorome thane
1, 1,2-Trichloro-
-1.2,.2-Trif luoroir.athane
Tr if luoroe thane
Vinyl chloride
Xylenes


Concentration
(ms/l)
ND
ND
NU
ND
ND
ND
KD
ND
MD
ND*
ND
0.09
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
Kb

ND
ND
ND-
ND


 *PT = Purge and Trap
  DI = Direct Injection
  HS - Headspace
  ND = < 0.05 mg/1
  ND* = < 0.10 mg/1
                                           B-13
                                                    OCA TECHNOLOGY DIVISION

-------
Project    1-628-G37
                                           GCA Control. No.  41769
                            DATA REPORT SHKET: TSDF
                           Volatile Organic Compounds
Samp le Ident if icat ion_
Analysis Date
                                      Instrument and  Samnle Volume*
                                      HP 5985 GC/MS    1:5 P'f	
                        1/10/85
 Sample Matrix	Water
Finnigan OWA GC/MS	
PE 3920 GC/FID    "
HP 5890 GC/FID	
Compound
Acetone
Acetonitrile
Allvl Alcohol
Aniline
Benzene
Bis (chloromethyl)ether
Bromodichloromethane
Bromoform
Bromome thane
Carbon disulfide
Carbon tetrachloride
Chlorobenzene
Chloroethane
2-Chloroethyl vinvl ether
Chloroform
Chlorome thane
C is-l,3-Dichloropropene
Cvclohexane
Cyclohexanone
Dibromochloromethane
1 , 2-Dibromoethane
Dichlorodif luoromechane
1 , 1-Dichoroethane
1 , 2-Dichloroethvlene
1 , 1-Dichloroethylene
1 , 2-Dichloropropane
Diethyl ether
Ethyl acetate
Ethyl acrvlate
Ethvlene
Concentration
(mg/l)
0.44
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND*
NU
ND*
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
Compound
Ethylene chloride
Ethvlene dibromide
Ethvlene dichlorids
Furfural
Isobutyl alcohol
Methvl acetate
Methvl alcohol
Methvl chloride
Methyl ethvl ketone
Methyl isobutyl k^'tone
Methvl methacrylate
Methylene chloride
n-Butvl alcohol
n-Propyl benzene
Stvrene
1,1,2.2-Tetrachloroethane
Tetrschloroethvlene
Tetrahvdrofuran
To luene
Trans 1,3-Dichloroorooene
1,1. 1-Trichlorcethane
Trichloroethvlene
Trichlorof luorometrhnne
[,1,1,2-Trichloro-
-1,2, 2-Tr if Luoromethane
Trif luoroethane
Vinyl chloride
^Xylenes

-
Concentration
(mg/l)
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND*
ND
0.61
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND

ND
ND
ND*
ND


*PT = Purge and Trap
 DI = Direct Injection
 HS = Headspace
 ND = < 0.05 mg/L
 N'D* = < 0.10 mg/l
                                          B-14
                                                   :CA  TECHi iOLCGY DIVISION

-------
  Project   1-628-niI
                                                          GCA  Control Me.
                                                        41814
                                                  DATA REPORT SHEET
                                                  Haadspace Analysis
  Sample I.D.
 ACC-SL-C1
                                                    Analysis Date    2/21/85
  Sample Matrix
Soil Core
Instrument   HP5985 GC/MS
Sample Dilution
C.A.S.
Number
74-87-3
74-83-9
75-01-4
75-00-3
75-09-2
67-64-1
75-15-0
75-35-4
75-34-3
156-60-5
67-66-3
78-93-3
71-55-6
56-23-5
75-27-4
*
Parameter
Chloromethane
Bromomethane
Vinyl Chloride
Chloroethane
Methylene Chloride
Acetone
Carbon disulfide
1 , 1-Dichloroethylene
1 , 1-Dichloroethane
Trans-1 L2-dichloroethylene
Chloroform
2-Butanone (MEK)
1,1, 1-Trichloroethane
Carbon tetrachloride
Bromodi Chloromethane
Total xylenes
Concentration
(ug/g)
ND •
ND
ND-
ND
11
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
C.A.S.
Number
79-34-5
78-87-5
10061-2-6
79-01-6
124-48-1
71-43-2
10061-01-5
110-75-8
75-25-2
108-10-1
127-18-4
108-88-3
108-90-7
100-41-4
100-42-5

Parameter
1,1,2, 2-Tetrachloroethane
1 , 2-Dichloropropane
Trans-1 , 3-dichloropropylene
Trichloroethvlene
Dibromech lor ome thane
Benzene
cis-1 , 3-DichloroproDVlene
2-Chloroethylvinylether
Bromof orm
4-Methyl-2-pjentanone (MIBK)
Tetrachloroethylene
Toluene
Chlorobenzene
Ethylbenzene
Styrene

Concentratic
(ug/g!
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND

Ln
       = PPm
 *C.A.S.  Numbers for xylene  isomers are as  follows;
                                               ND  «  <  5.0 ug/g
                                               K «* Quantitation below detection limit

                                  ortho- 95-47-6,  meta-  108-38-3, para-  106-42-3.
                                                                                         GCA
                                                                                                  Technology Divisioi

-------
    Project    1-628-037
                                                        GCA Control  No.
    Sample I.D.
ACC-SL-C1
    Sample Matrix    So11 Core
                                                 DATA REPORT SHEET

                                                  Headspace Analysis
                                                Additional Compounds
                    Instrument  HP5985 GC/MS
                                                  Analysis Date
                2/21/85
Sample Dilution
                      N.A.
C.A.S.
Number
75-05-8
107-18-6
542-88-1
110-82-7
108-94-1
106-93-4
75-71-8
60-29-7
141-78-6
140-88-5

Parameter
Acetonitrile
Allyl Alcohol
Bis (chloromethvl )ether
Cyclohexane
Cyclohexanone
1 , 2-Dibromoethane
Dichlorodif luorome thane
Diethyl ethor
Ethvl acetate
Ethyl acrylate

Concentration
(ug/g )
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND

L* t A • fa •
Number
98-01-1
78-83-1
79-20-9
67-56-1
79-41-4
71-36-3
103-65-1
109-99-9
75-69-4
76-13-1
420-26-2
Parameter
Furfural
Isobutyl alcohol
Methyl acetate
Methyl alcohol
Methyl methacrylate
n-Butyl alcohol
n-Propyl benzene
Tetrahydrofuran
Trichlorof luorome thane
1,1,2-Trichloro-
1,2, 2-trif luoroethane
1,1, 1-Trif luoroethane
Concentration
(ug/g)
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
w
I
    Concentrations  based on a comparison  of  the total ion area of  the compound with that of  the  internal
    standard.
    ug/g =
                                                                 ND  =  <  5.0 ug/g

                                                                 K = Quantitation below detection  limit
                                                                                       O0A
                                                                                       GCA
                                                                           .
                                                                           Technology Division

-------
Pro ject_
1-628-037
CCA Conrrol No.   41772
                            DATA REPORT SHEET; TSDF
                           Volatile Organic Compound:;
 Sample Identification  RTC-F-1B
 Analysis Date	I/10/85
 Sanple Matrix	Water 	
                           Instrument and Sanple Volume*
                           IIP 5935 C.C/MS	U1JTL	
                           Finnigan OVA GC/MS	
                           PE 3920 GC/FID 	
                           HP 5890 GC/FID	
Compound
Acetone
Acetonitrile
Allvl Alcohol
Aniline
Benzene
Bis(chlororaethyl)eth'-.r
Brotnodichloromethane
Bromofonn
-Bromome thane
Carbon disulfide
Carbon tetrachloride
Chlorobenzene
Chloroethane
2-Chloroethvl vinvl ether
Chloroform
Chlororaethane
C is-1 ,3— Dichloropropene
Cvclohexane
Cvclohexanone
Dibromochloroiae thane
1 , 2-Dibroicoethane
Dichlorod if luorome thane
1 , 1-Dichoroethane
1 ,2-Dichloroeth"l3ne
1 , 1-Dichloroethvlene
1 ,2-Dichlorooroocna
Diethvl ether
Ethvl acetate
Ethvl acrvlate
Ethvleno
Concentration
( mg/1)
0 I1}
Nn
ND
NT)
NH
ND
ND
ND
ND
ND
ND
ND
ND
ND*
ND
ND*
ND
ND
ND
ND
ND
NU
ND
ND
ND
ND
ND
ND
ND
ND
Compound
Ethvlene chloride
Ethvlene dibromide
Ethvlene dichloride
Furfural
Isobutyl alcohol
Methyl acetate
Methvl alcohol
Mathvl chloride
Methyl ethvl ketone
Methvl isobutvl ketone
Methyl methacrvlate
Methylene chloride
n-3utyl alcohol
n-Propyl benzene
Styrene
1,1,2.2-Tetrachloroethane
Tetrachloroethvlene
Tetrahydrofuran
To luene
Trans 1,3-Dichloroprooene
1,1. l-Trichlorceth.ciie
Trichloroethvlenc
Trichlorof luorowethaue
1,1,2-Trichloro-
-1 ,2 ,2-Trif luororaethane
Tr if luorce thane
Vinyl chlorida
Xvlenes


Concentration
(mR/1)
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND*
ND
0.20
ND
ND
ND
ND
ND
ND
ND
! ND
XD'
ND
ND

ND
ND
ND*
ND


 *PT =  Purge and  Trap
  DI =  Direct Injection
  HS =  Hsadspace

  ND = < 0.05 mg/1
  ND* = < 0.10 mg/1
                                                          TECHNOLOGY DIVISION
                                       B-17

-------
Project
L-623-037
                                           CCA Control
                                                             41772
                               DATA REPORT SHEETS

                                   Purgeablcs
Sacple I.D.	HElEll!	
                                         Anal%-sis Date
                                                 1/10/35
oacple Matrix  Water     Instrument  HP 5985 GC/HS  Sample Dilution  1:5 ?T
Parameter
Chloroaethane
Bcorooee thane
Vinvl chloride
Chloroethane
Methvlene chloride
Acetone
Carbon distilfide
1 , 1-DichlorcPthene
1,1-Dichlcroethar.e
Trans-1 ,2-dichloroethene
Chloroform
2-Butar.one
1,1, 1-Trichloroethane
Carbon tetrachloride
BroraodichloroTsethane
Total xylenss
Concentration
(WS/D
N!)*
NO
NO*
ND
ND**
ND**
ND
ND
ND
ND •''
ND
KD
ND
N'D
XD
ND
Parameter
l,l,2,2-Tetrachloro§thane
1 ,2-Dichloropropane
Trans-1 ,3-Dichlorooro^ene
Trichloroethene
Dibromochloronethane
Benzene
cis-1 ,3-Dichloroorooene
2-Chloroath"l vinyl ether
Brotnoform
! 4-Methyl-2-T3entanone
[Tetrachloroethene
iToluene
Chlorobenzer.e
Ethylbenzene
Stvrene

Concentration
(,g/U
ND
iN'D
ND
ND
ND
ND
ND
ND*
ND
ND*
ND
ND
ND
ND
ND

 PI = Purge and Trap
 DI * Direct Injection

 ND = < 50 ug/1
 ND* = <100 us/1

 ug/1 = ppb (for density of water = 1)
 K - Quantitation belov detection limit
 ND** = Elaak contaninaticn observed for this sample.
                                         B-18
                                                       •i^Ji^  Technology Division
                                       GCA

-------
             1-62S-C37
                                         GCA Coatrol No.   41772
                               DATA KSPURT SilEET

                             Qualitative Compounds*
Scnple I.D. _ RTC-F-13
                                  Analysis Date
                                                    1/10/85
Saaole Matrix
Instrument
                                               Sample Dilution   1 :5 PT
Parameter
Allvl Alcohol
Bis (chlororaethvl) ether
Cvclohsxar.e _
C'-"c lohexanone
Concentration
(yg/1)
NA
KD
ND
ND
1,2-Dibrocioetbane ! ND
pichlorodif luoroTWthsne
Diathvl ether
Ethvl acetate
Erhvl acrvlate
ND
ND
MD
NA
I
	 1 _
1
Parameter
Furfural
Isobutyl alcohol
Msthv! acetate
Methyl alcohol
Methvl methacrvlate
n-Butvi alcohol
n-Propyl benzene
T^t.r3hvdTof'jran
Trichlozof luorongthanf
1-1.2-Trichloro-
1,2,2-trif luoroethan*
Trif luoroethfine
Concentration
(yg/1)
ND
NA
ND
NA
ND
	
NA
MD
SD
N:D
ND
ND
 ^Concentration based on a comparison of the total ion area of the compound with
  that of the internal standard.
 NA
Not analyzed by purge and trap
 PT - Purge and Trap
 DI = Direct Injection

 ND = < 50 ug/1
 ug/1 = ppb  (for  density  of  water = 1)
                                           B-19
                                                         Technology Civision

-------
Project   ' 1-628-037
                    CCA Control No.
                            DATA REPORT SHEET: T3DF
                           Volatile Organic Compounds
 Sample Identification,
 Analysis Date
                                      Instrument and Snrapla Volume*
                                      HP 5985 GC/MSj_-5F[	
RTC-L-1C
1/1Q/85
 Sample Matrix	Water
Finnigan OWA GC/MS_
PE 3920 GC/FID 	~
HP 5890 CC/FID	
Compound
Acetone
Acetonitrile
Allvl Alcohol
Aniline
Benzene
Bis (chloromethvl) ether
Bromodichlorome thane
Bromoform
Bromome thane
Carbon disulfide
Carbon tetrachloride
Chlorobenzene
Chloroethane
2-Chloroethvl vinyl ether
Chloroform
Chloromethane
C is-l,3-Dichloropropene
Cvclohexane
Cvclohexanone
Dibromochlorome thane
1,2-Dibromoethane
Dichlorodif luoroinethane
I . l-Dichoroethane
1 ,2-Dichloroethylene
1 , 1-Dichloroethvlene
1 . 2-DichloroproDiine
Diethvl ether
Ethyl acetate
Ethyl acrvlate
Ethvlene
Concentration
(mg/1)
0.16
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND*
ND
ND*
ND
NO
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
Compound
Ethvlene chloride
Ethylene dibromide
Ethvlene dichloride
Furfural
Isobutyl alcohol
Methyl acetate
Methvl alcohol
Methyl chloride
Methyl ethyl ketone
Methvl isobutvl ketone
Methyl methacrylate
Methylene chloride
n— Butyl alcohol
n-Propyl benzene
Styrene
1 , 1 ,2 ,2-Tetrachloroethane
Tetrachloroethvlene
Tetrnhvdrofuran
Toluene
Trans l,3-Dichloroorot3er.e
1 . 1 . 1-Trichlorcethane
Trichloroethvlene
Trichlorof luorociethane
1,1,2-Trichloro-
-1 .2 ,2-Trif luororKjthane
Tr if luo roe thane
Vinvl chloride
Xylencs


Concentration
(mg/1)
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND*
ND
0.16
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND

ND
ND
ND*
::D


*PT = Purge and Trap
 DI = Direct Injection
 HS = Keadspace
 ND = < 0.05 mg/1
 ND* = < 0.10 mg/1
                                          B-20
                                                     CA TECHNOLOGY DIVISION

-------
Project
.1-623-037
Control  No.
               41777
                               DATA REPORT SiiKtTS

                                   Purgeables
Sanple I.D. 	RTC-L-IC

Sample Matrix  Water
                             Analysis Date

Parameter
Chlorotne thane
BromoTne thane
Vinvl chloride 	 _
Chlorcethane
Mgthvlere chloride
Acetone
Carbon disulfide
1 , 1-Oichloroethene
1 , 1-Dichloroethane
Trans-l ,2-dichlorcethenp
Chloroform
2-Butanone
1.1. 1-Trichloroethane
Carbon tetrachlcrids
Brnraodichloromethane
Total xvlenes

Concentration
(ug/1)
ND*
ND
ND*
ND
ND**
ND**
ND
N'T)
ND
ND '
ND
ND
ND
ND
ND
ND

Parameter
1A 1,,2,,2-Tetrachloroethane
1 ,2-Dichloropropane
Trans- 1 , 3-D ichloroprooene
Trichioroethene
Dibronochlorone thane
Benzene
c is- 1 , 3-D ichloropropene
2-Chlorosthyl vinyl eChar
[.Bromoform
1 4-Methvl-2-oentanone
lT«> t rach loroe thene
[TqluRne
IChlotobenzene
Ethvlbenzene
Stvrene


Concentration
(-g/D
ND
85
ND
ND
ND
ND .
ND
ND*
ND
ND*
ND
ND
ND
ND
ND

 PT - Purge and Trap
 DI = Direct Injection

 ND « <  50 ug/1
 ND* - <1QQ ug/1

 ug/i -  ppb  (for  density  of water  =  1)
 K - Quantitation b^lov detection  linit
  ND** = Blank contamination observed for this compound.
                                          B-21
                                                    GCA
                                                                .
                                                              Technology Division

-------
Project
1-628-027
                   GCA Control  No.   41777
Sanple I.D.
   RTC-L-1C
   DATA REPORT SHEET

 Qualitative Compounds*


.. _           Analysis Date
                                                            1/10/35
Sr.=ple Matrix   Water     Instrument   H?  5985 GC/MS  Sample Dilution   1:5 PT
Parameter
Allvl Alcohol
B is (chloromethvl) ether
Cvclohexane
Cvc lohexanone
1 j, 2-D Ibroiaoet hane
D ichlc rod if luoroma thane
Diethvl ether
Euhvl acetate
Concentration
(ug/1)
NA
ND
ND
NO
ND
ND
ND
Parameter
Furfural
Isobutyl alcohol _
Methyl acetate 	
Methyl alcohol
Methvl raethacrvlate_ _
Concentration
(wg/l)
ND
NA
ND
NA
ND
n- Butyl alcohol i NA
n-Pronyl benzene 	
Nn L Tetrahvdroftjrsn
ND
ND
 Schvl_acrvlate
                  NA
             _TrichlQTQfluoronethane_
                                                                        ND
!




1,1,2-Trichloro-
lA2J,2-trifluorQ9thane
Trifluotoethane
ND
ND
 ^Concentration based on a comparison of the total ion area of the compound with
  that of the internal standard.

 KA * Not analyzed by purge and trap

 PT » Purge and Trap
 DI = Direct Injection

 SID - < 50  ug/1
 ug/1 = ppb (for density of water = 1)
                                          B-22
                                                     GCA
                                                 HCA CORPORATION
                                                 Technology Division

-------
Project,
1-628-037
GCA Control i'io.
                 4173:
                            DATA REPORT SHEET: TSDF
                           Volatile Organic Compounds
 Sample Identification_RTC-L-2D
 Analysis Date         1/9?S5
                                      Instrument and Sample Volume*
                                      HP 5985 GC/MS  Nn 'IN uf Ion: F
 Sample Matrix	\Jater_
                           Finnigan OWA GC/MS_
                           PE 3920 GC/FID 	
                           HP 5890 CC/FID	
Compound
Acetone
Acetonitrile
Allvl Alcohol
Aniline
Benzene
Bis(chloromethyl)ethf;r
Bromodichloromethane
Bromoform
Bromome thane
Carbon disulfide
Carbon tetrachloride
Chlorobenzene
Chloroethane
2-Chloroethyl viuvl ether
Chloroform
Chloromethane
C is-l,3-Dichloropropene
Cvclohexane
Cvc lohexanone
Dibromochloromethane
1 ,2-Dibroraoethane
Dichlorod if luorome thane
1 , 1-Dichoroethane
1 .2-Dichloroethvlene
1 , 1-Dichloroethvlene
1 .2-Dichioroorops.ne
Diethvl ether
Ethvl acetate
Ethvl acrvlate
Ethylene
Concentration
(mg/1)
0.025
MD
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND*
ND
ND*
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
Compound
Ethylene chloride
Ethylene dibromide
Ethylene dichloride
Furfural
Isobutyl alcohol
Methyl acetate
Methyl alcohol
Methyl chloride
Methyl ethyl ketone
Methyl isobutvl ketone
Methyl methacrylate
Methylene chloride
n-Butyl alcohol
n-Propyl benzene
Styreno
1, 1,2,2-Tetrachloroethane
Tetrachloroethvlene
Tetrahydrofuran
Toluene
Concentration
(tns/1)
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND*
KD
0.016
ND
ND
ND
ND
ND
ND
ND
Trans 1,3-Dichlorcurooene! ND
1, 1,1-Trichloroethane ' > ND
Trichloroethvlene
Trichlorof luoroine thane
1,1,2-Trichloro-
-1.2,2-Trif luororea thane
Trifluoroe thane
Vinvl chloride
Xylenes


MD
ND
ND
ND
ND*
ND


*PT  =  Purge and Trap
  DI  =  Direct Injection
  HS  =  Headspace

  ND  =  < 10 ug/1
  ND* = < 20 ug/1
                                          B-23
                                         GCA  TECHNOLOGY DIVISION O'3A

-------
Pro icct.
            1-623-027
Control No.     41752
                                DATA RF.P03T SIIKK7C

                                    Purgoables
Sample I.D. 	

Sscple Matrix  Water
                                          Analysis Date ___l/9/8A
                          Instrument  HP 5985 GC/HS  Sample Dilution  No  dilution: PT
Parameter
Chlorine tfcane
Bromcnsethnne
Vinvl chloride
Chlqroethane
Methvlene chloride
Acetone
Carbon disulfide
1, 1-DichLoroethene
1 , i-Dichloroethar.e
Trans-1 ,2-dichloroethsne
Chlorofcra
2-But.ir.or.e
1,1, 1-Trichloroethane
Carbon tetrachloride
Broracdichloromethanc
Total xvler.es
Concentration
(ug/1)
Nn*
NO
NO*
ND
ND**
NO*-
ND
ND
ND
ND •'
! ND
ND
ND
ND
ND
ND
Faraneter
1 , 1^2 ,2-Tetrachloroe5hnne
1 .2-Dichloroprcoane
Trans-1 ,3-Dichloroorooene
Trichlotoethene
Dibromochloronethane
B^n^ene
r. is- 1 . 3-D ich lorop ropene
i 2-Chloroethvl vinyl ether
Bronipform
1 4-MethYl-2-pen.tanone
iTetrachloroe there
Toluene
Chlorobenzene
Ethvlbenzene
Stvrene . _ _
1
Concentration
(ug/1)
ND
ND
ND
ND
NB
ND
ND
ND*
ND
ND*
ND
ND
ND
ND
ND

 PT = Purge and Trap
 DI = Direct Injection

 ND - < 10 ug/1
 ND* = < 20 ug/1

 ug/1 = ppfa (for density of water  =  1)
 K 3 Quantitation below detection  limit

       =  Blank contamination observed for this compound.
                                            B-24
                                                             .
                                                              T-ichnology Civision

-------
Proiect
1-628-037
CtV Control No.
                -1732
                                DATA REPORT SHEET

                              Qualitative Compounds*
Sa-ple I.D.  _ RTC-L-2D
                       	Analysis  Date  ..__ j-/9/85.
       Matrix
             Instrument   HP, 5985  GC/M3  Sample Dilution No dilution; PT
Parameter
Allvl Alcohol
3i£(chioro:netnYl)eth«;T
Cyclohex-ine_
C'-c lohgxanqne
1.2-Dibrccocthane
Concentration
d.g/1)
NA
ND
ND
N'J
ND
Parameter
Furfural
Isobutyl alcohol
. Het;hvl_acet3te
. Hethvl alcohol
Methyl methacrYlate
Concentration
(yg/1)
ND
NA
ND
NA
ND
                                N'f)
                                                   alcohol
                                                           NA
Diethvl ether 1 ND
Ethyl ncstate Ni>
E:hyl acrvlate _ NA ••
1 r.— Protivl b«>nz<>r.e
L Tetrih^drofuran
1 Trichlorofluoronethane .
....'.. 1 1,1.2-Trichloro-
1 1^2,,2-tTif luoroethar.e
_ . i
1 Trif luQToetnsne
ND
ND
ND
ND
ND
 *Concentration based on a cocparison of the total ion area of the compound with
  that of  the internal standard.

 NA « Not  analyzed by purge and trap

 PT * Purge and Trap
 DI s Direct Injection

 ED = <  10 ug/1
  U2/1 = ppb (for density of vater =  1)
                               B-25

                                                                GC-'- CGFPORATICM
                                                                Technology Division

-------
            1-625-037
                                            GCA Control  No.
417S6
                               DATA REPORT SHEETS

                                   Purgeabl.es
Sample I.D. ___

Sample Matrix  Water
                                         Analysis Date  ^1/10/35
                         Instruaent  HP  5985 GC/KS  Sample  Dilution   1:5 PT

Parameter
Chloromethane
Bro:r.onethane
Vinyl chlorida
Chloroethane
Methylene chloride
Acetone
Carbon disulfide
1 , l-Dichloroethene
I, 1-Dichloroethane
Trans-1 ,2-dichloroethene
Chloroform
2- Brit anon e
1,1. 1-Trichlorcethane
Cirbon tetrachloride
Brcnodichlorcme thane
Toc.il xvienes

Concentration
(yg/1)
NO*
NL>
ND*
ND
ND**
ND**
NU
ND
ND -.
ND
ND
ND
ND
ND
ND
ND

Parameter
1 , I ,2 ,2-Tetrachloroethan?
1^2-Dichloropropane
Tranr.-l^G-Dichloroprooene
Tcichlgroethgne
Dibronochlorome thane
Benzono
cis-1 .3-Dichloronrcoer.e
> 2-Chloroethvl vinyl ether
tBrcraofonn
r4-HethYl-2-pon'tanone
Ta t rach loroe thene
i Toluene
tChlorobenzene
Ethvlbenrene
rStvrene^ .- _ T--,._ '


Concentration
(yg/1)
ND
N6
ND
ND
ND
ND
ND
ND*
ND
ND*
i ND
ND
ND
ND
ND

PT » Purge and  Trap
DI = Direct  Injection

•ND - <  50 ug/1
ND* = < IQQ ug/1
    1 »  ppb  (for density of water = 1)
    Quantitation below detection limit
             contamination observed for this compound.
                                        B-26
                                                    GCA
                                                              CCA coF-
                                                              Technology Division

-------
Project
      1-628-037
CCA Control Ko.
                                                                41736
                               DATA REPORT SHEET

                             Qualitative Compounds*
Sample I.D.  _  SOC-AP-lD
                                  Analysis Date
                                                   1/10/85
Sample Matrix Water Instrument HP 5935 GC/MS Saaple Dilution 1:5 PT

Parameter
Allvl Alcohol
Bistchlorocethyllether .
Cvclohexane
Cvc lohexanone
1 , 2-Dibroaoethane
D ichlorgd if luorome thane
Diethyl ecb.er
Eth*/l acetate 	
Ethyl acrylate _



Concentration
(us/D
NA
ND
Parameter
Furfural
Isobutvl alcohol
ND 1 Methvl acetate
ND
ND
ND
ND
N'D
NA .



Methyl alcohol
Methvl methacrylate
n-Butvl alcohol
n-Prooyl bensene
Te t rah vdro f uran
Trichlorof luoromethane
. 1,1,2-Trichloro-
lJ,2J,2-tTifluoroethane
Trtf luoroethane . . . .
Concentration
(wg/1)
ND
NA
ND
NA
ND
NA
ND
ND
ND
ND
ND
 ^Concentration based en a comparison of the total ion area of the compound with
  that of the internal standard.

 NA - Not analyzed by purge and trap

 PT * Purge  and Trap
 DI = Direct Injection
  ND
< 50 ug/1
  ug/1 = ppb (for density cf water - 1)
                                            B-27
                                                     GCA
                                                        GCA CCFPQfV-TlCN
                                                        Technology Division

-------
Project,
1-628-037
      CCA Control Mo.   417S6
                            DATA REPORT SHEET: YSDF
                           Volatile Organic Compounds
                                      Instrument and Sample Volume*
                                      HP 5985 GC/M3 1:5 FT	
 Sample Identification.
 Analysis Date
             SOC-AP-1D
             1/10/85
 Sample Matrix	Water
Finnigan OWA GC/MS_
PE 3920 GC/FID 	"
HP 5890 GC/FID	
Compound
Acetone
Acetonitrile
Allvl Alcohol
Aniline
Benzene
Bis(chloromethvl)ethf;r
Bromodichloromethane
Bromoform
Bromomethane
Carbon disulfide
Carbon tetrachloride
Chlorobenzene
Chloroethane
2-Chloroethyl vinvl ether
Chloroform
Chloromethane
C is-l,3-Dichloropropene
Cvclohexane
Cvclohexanone
Dibromochloromethane
1,2-Dibromoethane
Dichlorodif luorome thane
1 . 1-Dichoroethane
1,2-Dichloroethylene
1 . 1-Dichloroethvlene
1 ,2-Dichloropropans
Diethyl ether
Ethyl acetate
Ethyl acrvlate
Ethylene
Concentration
(mg/1)
0.41
ND
ND
ND •
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND*
ND
ND*
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
Compound
Ethylene chloride
Ethylene dibromide
Ethylene dichloride
Furfural
Isobutyl alcohol
Methyl acetate
Methyl alcohol
Methyl chloride
Methyl ethyl ketone
Methyl isobutyl k«tone
Methyl tnethacrylate
Methylene chloride
n-Butyl alcohol
n-Propyl benzene
Styrene
1,1,2,2-Tetrachloroethane
Tetrachloroethvlene
Tetrahvdrofuran
To luene
Trans 1.3-Dichloropropene
1.1, 1-Trichlorcethana
Trichloroethylene
Trichlorof luo rone thane
1,1,2-Trichloro-
-1 ,2 ,2-Trif luorotnethane
Tr if luoroe thane
Vinvl chloride
Xylenes


Concentration
(mg/1)
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND*
ND
0.35
ND
ND
ND
ND
ND
ND
ND
ND
N'D
ND
ND

ND
ND
ND*
ND


*PT = Purge and Trap
 DI = Direct Injection
 HS = Headspace

 NU = < 0.05 mg/1
 ND* = < 0.10 mg/1
                                          B-28
                                        OCA TECHNOLOGY DIVISION

-------
Project  1-62B-037
                                      GCA Control No.  41788
                                                DATA  REPORT SHEET

                                                    Purgeables
Sample  I.D.   SOC-SI-1B
                               Analysis  Date    1/9/85
Sample Matrix Aqueous
Instrument   HP5985  GC/MS
Sample Dilution   1;5°
C.A.S.
Number
74-87-3
74-83-9
75-01-4
75-00-3
75-09-2
67-64-1
75-15-0
75-35-4
75-34-3
156-60-5
67-66-3
78-93-3
71-55-6
56-23-5
75-27-4
*
Parameter
Chloromethane
Bromomethane
Vinyl Chloride
Chloroethane
Methylene Chloride
Acetone
Carbon disulfide
1 , 1-Dichloroethylene
1 , 1-Dichloroethane
Trans-1 , 2-dichloroethylene
Chloroform
2-Butanone (MEK)
1,1, 1-Trichloroethane
Carbon tetrachloride
Bromodi ch lor ome thane
Total xylenes
Concentration
(ug/1)
ND*
ND
ND*
ND
850
1600
ND
ND
ND
ND
ND
ND
ND
ND
ND
2400
C.A.S.
Number
79-34-5
78-87-5
10061-2-6
79-01-6
124-48-1
71-43-2
10061-01-5
110-75-8
75-25-2
108-10-1
127-18-4
108-88-3
108-90-7
100-41-4
100-42-5

Parameter
1,1,2, 2-Tetrachloroethane
1 , 2-Dichlor,opropane
Trans-1 , 3-dichloropropylene
Trichloroethylene
Dibroirochlorome thane
Benzene
cis-1 , 3-Dichloropropylene
2-Chloroethylvinylether
Bromoform
4-Methvl-2-pentanone (MIBK)
Tetrachloroethylene
Toluene
Chlorobenzene
Ethylbenzene
Styrene

Concentratio
(ug/1)
ND
' ND
ND
ND
ND
2500
ND
ND*
ND
ND*
ND
6300
ND
ND
ND

PT = Purge  and  Trap
DI = Direct Injection

ug/1 - ppb  (for density of water)

*C.A.S. Numbers for xylene isomers  are  as follows;
                           ND = < 500 ug/1
                           ND* » < 1000 pg/1
                           K = Quantitation below detection limit
             ortho-  95-47-6,  meta- 108-38-3, para-  106-42-3.
                                                                                       -*^*r -*+l*r tut mm

                                                                                       GCA
                                                                                                GCA
                                                                                                Technology Divisioi

-------
Project 1-628-037
                                    GCA Control  No.  41788
Sample I.p.    SOC-SI-1B
Sample Matrix  Aqueous
                                             DATA REPORT SHEET

                                            Additional Compounds
Instrument  HP5985  GC/MS
                              Analysis Date    1/9/85
Sample Dilution  1;50
V* • f\ • ^ •
Number
75-05-8
107-18-6
542-88-1
110-82-7
108-94-1
106-93-4
75-71-8
60-29-7
141-78-6
140-88-5

Parameter
Acetonitrile
Allyl Alcohol
Bis (chloromethyl ) ether
Cyclohexane
Cyclohexanone
1 , 2-Dibromoethane
Di ch lor odif luorome thane
Diethyl ether
Ethyl acetate
Ethyl acrylate

Concentration
(ug/1)
ND
NA
ND
ND
ND
ND
ND
ND
ND
NA

C.A.S.
Number
98-01-1
78-83-1
79-20-9
67-56-1
79-41-4
71-36-3
103-65-1
109-99-9
75-69-4
76-13-1
420-26-2
Parameter
Furfural
Isobutyl alcohol
Methyl acetate
Methyl alcohol
Methyl methacrylate
n-Butyl alcohol
n-Propyl benzene
Tetrahydrofuran
Trichlorof luorome thane
1,1, 2-Trichloro-
• 1^2j2-trif luoroethane
1,1, 1-Trif luoroethane
Concentration
(ug/1)
ND
MA
ND
NA
ND
NA
ND
ND
ND
ND
ND
Concentrations  based on a comparison of  the total ion area of the  compound with that of the internal
standard.
PT = Purge  and  Trap
DI = Direct Injection

ug/1 = ppb    (for density of water)
                         ND - < 500 ug/1
                         NA = Not analyzed by  Purge  and  Trap
                         K = Quantitation below detection limit
                                                                                   GCA
                                                                                           GCA CORPOR-'-' ."J: :
                                                                                           Technology Division

-------
            1-G2S-037
CCA Control No.
41794
                               DATA REPORT SHEETS

                                   Purgeables
Saaple I.C. 	JOC-Jil-JJD	Analysis Date

Saaple Matrix Water      Instrument  .H? 5985 .GC/MS. Saaple Dilution _1;50_PT_

Parameter
Chloroaiethane
Procomethnne
V;r.yl chloride
Chloroethane
Methvlene chloride
Acetone j
Carbon disulfide
1 , 1-Cichlorosthene
1 , 1-Dichloroethane
Trans- 1^2-dichloroether.p
Chloroform . .
2-3utanone
1,1, 1-Trichloroethane
Carbon tetrachlcride
BrcTucdichiorcme thane
Total xvlenes

Concentration
(ug/1)
NO*
NO
NO*
NO
NO**
ND**
MD
MD
ND
ND •'
ND
ND
I ND
ND
ND
970

Parameter
1 ,1 ,2 ,2-Tetrachlotoethar.e
1 ,2-Dichlorooropane
Trans-1 ,3-DichloroprQuene
Trichloroethene
Dibromochlororoethan^
Benzene
c is-l^S-Dichlgroproegne
2-Chloro
-------
Project
             1-628-037
CCA Control No.
                                                                  4179.!
                               DATA REPORT SHEET

                             Qualitative Compounds*
                                        Analysis Date
       I.D.    SOC-ST-2D	

Saxple Matrix  Water       Instrument  HP 5985 GC/MS  Sample Dilution  1:5° PT
Parameter
Allvl Alcohol
E is (chlorocethvl) ether
Cvclob^xane
Cyclohexanone
1 . 2-Dibronoethane
Dichlcrodif luorocethar.e
Die-hvl ether
Ethyl acetate
Ethvl acrvlate



Concentration
(ug/1)
NA
ND
NO
ND
ND
ND
N'D
Mi)
Ni ''



Parameter
Furfural
Isobutvl alcohol
Mejhvl acetate
Methyl alcohol
Methyl raethacrylate
n-Bntyl alcohol
L nrPrapyl^b^nzene
Tctrahydrofuran
Trichlorof luorome thane
1,,1,2-Trichloro-
1 ^2^1-trif luoroethnne
Tr if luo roe thane
Concentration
(yg/1)
ND
NA
ND
NA
ND
NA
ND
ND
ND
ND
ND
 ^Concentration based on a comparison of the total ion area of the  compound with
  that of the internal standard.

 NA « Not analyzed by purge and trap

 PT » Purge and Trap
 DI = Direct Injection

 SID - < 500 ug/1
 ug/1 - ppb (for density of water = 1)
                                           B-32
                                                    GCA
                                                              CCA CCRFCnATlCN
                                                              Technology Division

-------
Project.
1-628-037
                                 CCA
                       41794
                            DATA REPORT SHliliT: T15UK
                           Volatile Organic Compounds
 Sample Identification
 Analysis Date 	
             SOC-SI-2D
             1/9/85
                                      Instrument and  Sample  Volume*
                                      HP 5935 GC/MS   1:5Q  PT	
 Sample Matrix	Water
Finnigan OWA GC/MS_
PE 3920 GC/FID 	~
HP 5890 GC/FID	
Compound
Acetone
Acetonitrile
Allvl Alcohol
Aniline
Benzene
Bis(chloromethyl)eth^r
Bromodichloromethane
Bromoform
Bromome thane
Carbon disulfide
Carbon tetrachloride
Chlorobenzene
Chloroethane
2-Chloroethyl vinvl ether
Chloroform
Chloromethane
C is-1 ,3-Dichloropro^enn
Cvclohexane
Cvclohexanone
Dibromochlorome thane
1 ,2-Dibromo ethane
Dichlorodif luorome thane
1 , i-Dichoroethane
1,2-Dichloroethylene
1 , 1-Dichloroethvlene
1,2-Dichloropropane
Diethyl ether
Ethvl acetate
Ethvl acrvlate
Ethylene
Concentration
(mg/1)
1.77
ND
ND
ND
4.33
ND
ND
ND
ND
ND
ND
ND
ND
ND*
ND
ND*
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
Compound
Ethylene chloride
Ethylene dibromide
Ethylene dichloride
Furfural
Isobutyl alcohol
Methvl acetate
Methvl alcohol
Methvl chloride
Methyl ethyl ketona
Methvl isobutyl ketona
Methyl methscrvlate
Methvlene chloride
n-Butvl alcohol
n-Propyl benzene
Styrene
1,1,2.2-Tetrachloroethane
Tetrachloroethylem:
Te t rahyd ro f uran
Toluene
Trans 1,3-DichloroDrooene
1,1. l-Trichlorcathane
Trichloroethvlene
Trichlorof luorotns thane
1,1,2-Trichloro-
-1,2,2-Trif luoroaethane
Trif luo roe thane
Vinvl chloride
Xylenes


Concentration
(mg/1)
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND*
ND
0.90
ND
ND
ND
NU
ND
ND
1.47
ND
ND
ND
ND

ND
L ND
ND*
0.97


 *PT  = Purge and Trap
  DI  = Direct Injection
  HS  = Headspace

  ND = < 0.50 mg/1
  ND* = <• 1.00 mg/1
                                         B-33
                                                     GCA TECHNOLOGY DIVISION

-------
Project
1-623-037
CCA Control No.   41796
Sample  I.D. .SOC^SI;
                   DATA KLIOKT SHKETSJ

                       Purgaables


                             Analysis Date .i^
Sample Matrix   Oil  (PEC)Instrument  HP 5985 GC/MS  Sample Dilution 1:500 PT
Parameter
Chloromethane
Bromcrae thane
Vinyl chloride
Chloroethane
Methvlene chloride
Acetone
Carbon disulfide
1 , 1-Dichloroethene
1, 1-Dichloroethane
Irans-l_12-dichloroethene
Chloroform
2-Butanone
1 , 1 » 1-Trichloroethane
Carbon tetrachloride
Bromodichlorome thane
Total xylenes
Concentration
(vg/1)
ND*
ND
ND*
ND
16300*
*m
ND
ND
ND
ND''
ND
ND
N»
ND
ND
77400
Paraneter
lJlA2,2-T«trachIorcethane
1 . 2-D ich loropropaue
Trans- 1 , 3-Dich loroorotJene
Trichloroethens
Dibromochlorome thane
Ben^enn
cis-1.3-Dichlorocrcpene
2-Chloroethvl vinyl ether
Bromoform
4-Methvl-2-oentanone
Tetrachloroethene
Toluene
Chlorobenzene
Ethylb^nzene
Stvrene

Concantration
(i-g/1)
ND
NT)
ND
ND
ND
7000
ND
ND*
ND
ND*
ND
47300
ND
18000
ND

PT = Purge and Trap
DI = Direct Injection

ND = < 5000 ug/1
ND* = <10000 wg/1

ug/1 = ppb (for density  ot  water - 1)
K = Ouantitation below detection limit
* = corrected for blank value
                                        B-34
                                       GG
                                                         •£&  Technology Division


-------
Project
1-628-037
GCA Control No.  41796
                               DATA REPORT SHEET


                             Qualitative Compounds*
Sample I.D. JLQCr.SI-3B
                           Analysis Date   1/15/85
Sample Matrix  .Oil  (PEG)Instrument ,HP 5985 GC/MS  Sample Dilution 1 : 500 PT
Parameter
Allvl^Alcohol^
Bis(chloromethvl)ether
Cyclohexane 	
Cvdohexanone
1.,2-Dibromo ethane
Dichlorodif luoromethane
Diethyl_ether_
£5hyl_acetate_ _
Ethyl acrylate



Concentration
(ug/1)
ND
ND
ND
NA
ND
ND
ND
ND
NA



Parameter
Furfural
IsobutvJ alcohol „ n „
Methyl acetate
Methyl alcohol
Methyl methacrylate
n-Butyl alcohol
n-Prop'/l benzene.
Tetrahydrofuran
Trichlorof luoromethane
1^1,,2-Tricbloro-
U2,2-trif lugroethane
Trifluoroethane . „ _
Concentration
(ug/D
ND
NA
ND
NA
ND
NA
ND
ND
ND

ND
ND
^Concentration  based  on a comparison of the total ion  area  of  the compound with

  that of  the  internal standard.


NA " Not  analyzed.by  purge and trap


PT « Purge  and  Trap
DI » Direct Injection


ND = <5000 ug/1
 ug/1 a ppb (for density of water = 1)
                                           B-35
                                       •^^ -^^ *^^*m

                                       GCA
                                                              GCA CORPORATION
                                                              Technology Division

-------
Project    1-62S-037
                   GCA Control, Ho.  41SOQ
                            DATA  REPORT  SHEET:  TSDF
                           Volatile Organic  Compounds
                                       Instrument  and  Sample  Volume*
                                       HP  5985 GC/HS   1:20 PT	
 Sample Identification
 Analysis Date 	
TI-RP-1B
1/9/85
 Sample Matrix 	
Water
Finnigan OWA GC/MS_
PE 3920 GC/FID 	
HP 5890 GC/FID	
Compound
Acetone
Acetonitrile
Allvl Alcohol
Aniline
Benzene
Bis(chloromethvl)eth*:r
Bromodichloromethane
Bromoform
Bromomethane
Carbon disulfide
Carbon tetrachloride
Chlorobenzene
Chloroethane
2-Chloroeth'vl vinvl ether
Chloroform
Chloromethane
C is-l,3-Dichloropropene
Cvclohexane
Cvclohexanone
Dibroraochloromethane
1,2-Dibromoethane
D ich lorod if luorome thane
1 , 1-Dichoroethane
1,2-Dichloroethvlene
1 , 1-Dichloroethvlene
1,2-Dichloroprooane
Diethvl ether
Echvl acetate
Ethyl acrvlate
Ethvlene
Concentration
(mg/1)
0.63
ND
ND
ND
1.04
ND
ND
ND
ND
ND
ND
ND
ND
ND*
ND
ND*
ND
ND
ND
ND
•ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
Compound
Ethvlene chloride
Ethylene dibromide
Ethvlene dichloride
Furfural
Isobutvl alcohol
Methvl acetate
Methvl alcohol
Methvl chloride
Methvl ethyl ketone
Methvl isobutvl ketone
Methvl methacrvlate
Methylene chloride
n-Butvl alcohol
n-Propyi benzene
Styrene
1 , 1 ,2 ,2-Tetrachloroethane
Tetrachloroethvlene
Tetrahvdrofuraa
Toluene
Trans 1.3-Dichlorcprooene
1 ; 1 , 7-Trichloroethane
Trichlcroethvlene
Triclilorof luornmethane
1,1,2-Trichloro-
- 1 , 2 , 2-T-if luoromethane
Tr if iuoroe thane
Vinvl chloride
Xylenes


Concentration
(mg/1)
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND*
ND
0.42
ND
ND
ND
ND
ND
ND
0.75
ND
:ID
ND
ND

ND
ND
ND*
0.17


*PT = Pur^e nnti Trap
 DI = Direct Injection
 HS = Headspace
 ND = < 0.20 mg/1
 ND* = < 0.40 ng/1
                                          B-36
                                                    GCA  TECHNOLOGY DIVISION 3-9A

-------
Project
L-628-037
GCA Control No.   41806
                               DATA REPORT SIIKETS

                                   Purgeables
Sample I.D.
                             Analysis  Date .
Sample Matrix _.Qil  fp_rg) Instrument  HP,5985 ,GC/HS  Sanple Dilution   1:500  PT_
Parameter
Chlorome thane
Bromome thane
Vinyl chloride
Chloroethane
Methvlene chloride
Acetone
Carbon disulfide
1 , 1-Dichloroethene
1 , 1-Dichloroethane
Trans-1 ,2-dichloroethene
Chloroform^
2-Butanone
1,1, 1-Trichloroethane
Carbon tetrachioride
Bromodichlorome thane
Total xylenes
Concentration
(ug/1)
ND*
ND
ND*
ND
40900*
ND
ND
ND
ND
ND.'
ND
ND
ND
ND
ND
58000
Parameter
1,1,2,2-Tetrachloroethane
1 »2-Dich]oropropane
Trans— 1 ,3— Dichloropropene
Trichloroethene
Dibromochlorome thane
Benzene
cis-liS-Dichloropropene
2-Chloroethvl vinyl ether
Bromoform
4-Methyl-2-pentanone
Tetrachloroethene
Toluene
Chlorobenzene
Ethylbenzene
Stvrene

Concentration
(•jg/1)
ND
N&
ND
N7D
ND
6800
ND
ND*
ND
ND*
ND
19000
ND
25000
ND

PT « Purge and Trap
DI » Direct  Injection

ND = < 5000  ug/1
ND* = < 10,000^/1

ug/1 = ppfa  (for density  of water  =  1)
K = Quantitation below detection  limit
* = corrected for blank  value
                                         B-37
                                       GCA
                                                             GCA CORPORA ncr.1
                                                             Technology Division

-------
Project
1-628-037
GCA Control No.
                               DATA REPORT SHEET


                             Qualitative Compounds'*
Sample I.D.   TI-SB-ID
                           Analysis Date   1/15/85
Sample Matrix  Oil  (PEG! Instrument  HP 5985 GC/MS  Sample Dilution 1:500  PT
Parameter
Allvl Alcohol
Bis(chloromethyl)ether
Cyclohexane
Cvclohexanone
lJ2-Dibromo§thane
Dichlorodifluoromethane
Diethyl ether
Ethyl acetate
Ethyl acrylate



Concentration
(ug/1)
NA
ND
ND
NA
ND
ND
ND
ND
NA
"..


Parameter
Furfural
Isobutyl alcphol 	
Methyl acetate ..
Methyl alcohol
Methyl raethacrylate
n-Butyl alcohol 	
n-Propyl benzene
^Tetrahydrofuran 	
Trichlorof luoromethane .
l.l.2-Tr:j.ch}Qro-
l , 2 ,2-trif luoroethane
Trifluoroethane 	 	
Concentration
(ug/D
ND
NA
ND
NA
ND
NA
ND
ND
ND
ND
ND
^Concentration based on a comparison of the total ion area of the compound with
 that of the internal standard.                      *


NA = Not analyzed by purge and trap


PT = Purge and Trap
DI = Direct Injection


ND = < 5000 ug/1
ug/1 = ppb (for density of water = 1)
                                         B-38
                                      GCA
                                                             GCA CORPORATION
                                                             Technology Division

-------
    APPENDIX C




RADIAN CORPORATION




DATA REPORT FORMS
        C-l

-------
                in NO:  M7M
          SAMI'U CONTROL HO:  4210-7
                         LinillC
OATC
DATE ANALYZED:
fll/22/85
    COMPOUND
                                           CONCENTRATION
                                                                           COMPOUND
                  CONCENTRATION
               ING-C/KL»   IKS/LI*
PARAFFINS
r.-3 vac
ISOflUTANE
I!-OUTAN£
M E 0 H E X A N f
?i3-niMETHYLClUTAHC
1S3HEXANE
J-MCTMYLPENTANE
?,4-OIHiTHYLPEHTANE
rYfL3»CKANC
irTHYLCYCLOIIEXANE
N-OC1 AtJE
C6 MKAMC
C7 .UK AM.
C7 »LKAIir
C? AI.KAMT
CT *LKA»/E
C8 ALKANT
I C1 AlKANf
ro CT ALKANE
CIO* ALKANE
C10« »l.K»HE
cio* ALKAIIE
C|0» ALKA'IE
C10« ALKANE
OLEMHS
M-r It.'ENE
O1AL AR3HHICS
nr-mwE
inn AN
TOTAL tULOSfNATfn I'C
TRicHLonorLORonriiurir
HLTHYLENt CHLORIDE
rt'LDROFORH

776.0
II.)
12.0
Ifk
• u
&.:.
4.1
2.4
13.8
9.3
5.7
?.S
6.0
5.0
7.4
13.0
2.5
3.3
4.3
a. A
6.9
2.5
3.0
3.0
*.R

23.5

1630.0
3.0

12.3
13.9
 VtRIAPLC RCCOVfY TMROUSH ORYINS .SYSTEM - CONCENTRATIONS
(C) CONCENTRATIONS UERE CALCULATED
USING VALUES OF
6 FOR THE
TOTAL OXYGENATED HC(B)
ItPROriliOL 2.5 0.004

UNIDENTIFIED VOCICI

UNIDENTIFIED VOC 7.4 0.009
UNIDENTIFIED VOC . 9.7 0.012
UNIDENTIFIED VOC 9.2 O.P11
UNIDENTIFIED VOC 6.2 0.007

PARAFFINS 91H.6 1.077
OLEFIHS 33.5 0.027
TOTAL AftGMATlCS 1633.0 1.771
TOTAL HALOGCNATEO HC 13.0 0.09?
TOTAL OXYGENATED HC 2.5 O.OOMBI
UNIDENTIFIED VOC 32.5 0.039
-------
             firm  in  NO:   4i76i
             SAMPLE  CONTROL NO:
             SAMPLE  TYPE:    LIQUID
                                                        DATE SAMPLED:
                                                        DATE ANALYZED:
                                                                                                                    Ol/22/Bb
       COMPOUND
   CONCENTRATION
CNG-C/HL)   IHG/LX
                                                                               COMPOUND
   CONCENTRATION
(NG-C/ML)   IMG/LI*
PARAFFINS

 C-3 VOC
 II-HCXANC
 Cf, ALKAVE
 ci ALKANE
 C10» ALKANE
 CIO* ALKANE

OLTFIMS

 T-?-HEXENE

TOTAL HALOGENATED HC

 TRICHLOROFLOROM^THAHE
 METHYLCHE CHLORIDE

       IFIED VOC(C>
 IINIOENTIFIED VOC
 IIHIDENTiriED VOC

PARAFFINS
OLEFIHS
T1TAL MALOGENATED MC
UNIOENT IF ICO VOC

TOTAL NMMC
                                               20.8
                                                4.9
                                                7.6
                                                2.4
                                                3.4
                                                2.0
                                              121.0
                                               20.3
                                                6.7
            0.024
            0.006
            0.009
            0.002
            0.004
            0.002
            0.142
            0.23HA)
            0.047
4.7
9.5
40.7
121.0
6.7
14.2
0.006
0.011
0.048
0.142
0.047
0.017IC)
   162.6
                                                       0.254
n
i
U)
 CA)   ARTIFACT COMPOUND - CONCENTRATION  NOT  USED IN TOTAL NMMC CALCULATIONS.
    VAR|A(UF RECOVERY THROUGM ORYPtr. SYSTEM - COSCE fITRA T IONS NOT USED  IN TOTAL NMMC  CALCULATIONS.
 CC»   COI4CENTRAT IONS WERE CALCULATED  USING  VALUES  OF  6 FOR THE CAR113N NUMOFR AMI) H6 F "l»  THE  MOLECULAR WEIGHT.
      UNITS  ARE EUUIVALfHT TO PPM  ASSUMING  A  DENSITY OF I.

-------
      F irin in NO:  n«i5
      sAtc'ir CONTROL NO:   42in-29
      SVILT TYPE:   SOLID
                                                        DATE SAMPLED:
                                                        DATE ANALYZED:
 I1/15/B1
 01/03/05
                                                                                                                                  m
                                                                                                                                   I)
                                                                                                                                   a
COMPOUND
   CONCFUTRAT ION
UIO-C/G)     |UG/C)i
                                                                       COMPOUND
   CONCENTRATION
(NG-t/0)    IUS/G)«
PARAFFINS
f' £ Q"£ \ A*| £
CYCLOPCUHNE
2«3-f)!.'ir. THYLflllTA'lf
1 SOHFX Aflf
3-M* Tt1YLr'ENT AUF
N-HEXAHE
"F THYLCYCLOPENTANF
CYCLOIKXANE
JSOHEPTMif
3 -ME THYLHE XA'lf
II-HEPT ANE
HFTMYLrYCLOHFXAf.T
?. t'i-O 1 MF. TH YLI'F. X J'lf
2i3»4-TRJMriMYLnEllTAME
3-METHYLHrpTANC
2i2**-V* IMEIMYLI'EXANE
o (1-OCTANE
1 M-N3NANE
*" N-DECA»jF
•l-ijrjOEC* Mr
C7 ALKAME
C? ALKANF.
C7 ALKA'IE
C7 ALKA*'E
Cfl ALKA'.'E
CP ALKANE
CO ALKAME
C» ALKAMF.
Cfl ALKAME
ce ALKAvf
C9 ALKANF
C9 ALKAVF
CQ ALKANE
r.<) ALKAIIC
C9 ALKANE
C" AlKA'lE
C9 ALKAV'E
cio* ALKANE
(A) ART|C»CT COMPOUND
111) VAIIIAOLf HtCOVWY
< C ) C O'lCFNl" AT ITMS WE"

H5.1
26 J.O
2A6.0
79J.9
1273.0
11000. (I
PP30.0
796.0
1320.0
1129.0
4210.0
251C.O
1R70.0
1160.0
5550.0
1310.0
4990.0
17000.0
376P9.0
87* 00.0
513. 0
457.0
995.0
1 67P.Q
456.0
370.9
377.0
PB6 .n
674. P
4020.0
7 7 A A
* 1 1 » 'J
432."
191.3
1550.?
3290.0
4^40.0
!,1f,0.0
2490. 0
?.->ao.n

0.2
0.3
0.3
0.9
1.5
13.2
2.1
0.9
5.2
3.7
5.1
2.9
2.2
1.1
6.6
1.8
5.9
20.2
44.6
101.7
a. 6
0.5
1 .2
2.0
0.5
0.4
0.4
1 .1
0.8
4.B
Oq
• 7
0.5
0.2
l.P
3.9
P. 2
6.5
3.0
3.9
• COMCf NTfvATION NOT IISF" IN TOTAL NHHC
THROUGH OHYING SVSTC" - C3HCtHIP A T IONS
E CALCULATED USIN3 VALUER OF
f. FOR Tilt
PARAFFINS (CONT*0)
C*0« ALKANE
cio* ALKANE
Cl?» ALKANE
CIO* ALKANE
CIO* ALKANE
CIO* ALKANE
CIO* ALKANE
CIO* ALKANE
CIO* ALKANE
CIO* ALKANE
CIO* ALKANE
CIO* ALKANE
CIO* ALKANE
CIO* ALKANE
C»0* ALKANE
CIO* ALKANE
Clfl* AtKANE
CIO* ALKANE
CIO* ALKA«JE
CIO* ALKANE
CIO* ALKANE
CIO* ALKANE
CtO* ALKANE
CIO* ALKANE
CIO* ALKANE
CIO* ALKANE
CIO* ALKANE
CtO* ALKANE

OLEFINS
2i1i1-TRJHE-1-PENTENE
I-HCTHYLCYCLOHEXENE
1-OCTEHF
C-2-OCTENE
A-piunriE
P-.P1HEHE
LIHONENE
C" ALKFME
CALCULATIONS.
NOT USED ttt TOTAL HMHC CALCULATIONS.
CAROON NUHMLIt AND H6 F QR THE HOLECUI.AP UFITMT.

9930.0
20600.0
13300.0
9110.0
10300.0
9270.0
22700.0
36100.0
9960.0
12800.0
1690.0
3340C.O
7050.0
11400.0
2273.0
10500.0
12100.0
226CO.O
13300. P
11800.0
4900.0
5200.0
14ROO.O
54AO.O
74SO.O
14100.0
13000.0
1960.0


959.0
1350.0
1450.0
461.0
2020.0
12400.0
Ifl20d.fl
3300.9



11.8
24.4
5.8
1.2
2.2
1.0
6.9
3.2
1.6
5.2
5.6
36.0
fi.4
1 3.5
2.7
1 ?.5
14.3
26. E
15. fl
14.0
5.6
£.2
17.6
6.5
9.1
16.7
15.4
2.3


1 .1
1.5
1.7
0.5
3.3
14.1
2(1.7
3.9


     AT FOlllVAfMT  TO  PPM  A'SIIMIHG A (UN-MTV "F 1.

-------
                 r i r L n in no:  11 B 15
                 SA^IUr. CONTPOL HO:   1210-29
                 SAPIM.F TTPE:   SOLIC
                                                                                                      DATE SAHPLED:
                                                                                                      DATE ANALYZED:
   11/15/81
   01 /03/P.5
          COMPOUND
            
    cq AIKEHE
    C9 ALKf'JE
    cio« AI.KHJE
    cio* AL>T"E
    CIO* ALKENE
    CIO* ALKENF
    CIO* ALKFNE
    CIO* ALTNE

   TOTAL AROMATIC"!

    REII?ENF
    TOLUENE
    I SOPROPYLHLN?rNr
n
Ul
 I «3ib-TR
 ISO«UIYLOENZEIIE
 P-ISOPROPYLIOI.U'~r'E
 I NO* 'I
 inortiE
 II-BUTYLSFNZEWE
 P-OIEIHYLPEMZEUE
 CIO* AROHAIJC
 CIO* APOHAT1C
 CIO* AROMATIC

T1TAL MALOrirfJ»Trn  HC

 CHLOPOHf TH«nr
    MEIHYLEK'E CHLORITE
    1 <1 ,1-TRKHLOFOETHA'ir
    UriIOENTIFlEO HAI 03CNATED
                                                  CONCENTRATION
                                               (NT.-C/G)     (UG/G>»
                           HC
5920.0
7110.0
13700.0
11303.0
13100.0
5070.0
1 •'000.0
5?10.0
1980.0
1360.0
J320.0
12AO.O
"\MO.O
510Q.O
I2noo.o
1630.0
3R30.0
592 l.d
6739.0
2«600.0
11ROO.O
11000.0
11800. 0
l?000.0
1250. 0
269.0
flit .0
215.0
143.0
6.9
8.3
16.0
16.7
15.3
5.9
19.9
6.5
2.1
1 .5
3.7
1 .8
".2
6.1
11.2
5.2
1.3
6.5
7.2
32.0
13.2
12.3
16.6
13.1
5.3
0.7
5.1
1 .1
O.S
                                                                                 COMPOUND


                                                                        TOTAL  OXYUNATEt) HC   CONCFHTRA!MMS  WERE CALCULATED  USING  VALUES Of 6 FOR THE CARB3U  NUMnER AND H6 FOR THE  MOLECULAR UEIfiHT.
      «   UNITS ART roi/IV«lE*JT  TT PP" AS^UMIK",  A  DENSITY OF I.

-------
                 rinn in no:  «ii7J
                 SAMPLE CONTROL NO:  4219-M
                 SAMPLE ivpt:   Linuin
                                                        PAIE SAMPLED:
                                                        DATE ANALYZED:
                                                                        oi/22/»i
          COMPOUND
    nut M»L?'»tN»irn HC
    1EIMYUNC  CHLORint
    CARIIOM  TflRACHLOP IDE
   CONCIN1RAIION
ING-C/HI.)   IM1/L)'
    3H.2    0.439IAI
     6.4    0.045
     2.0    0.026
                                                                                  COMPOUND
   CQNCCNTRM ION
INO-C/PLI   IHS/ll*
    T3TAL

    I3TAL
                      MC
                                                    a.*
            0.071

            0.071
n
     |At   ARTIFACT COHPOIlNn - CONCENTRATION  NOT  USED IN TOTAL NHIT CALCULATIOMS.
     Ill)   VADIAniE RECOVERY TI'ROIISH ORYINS SYSTEM - CONCENTRATIONS NQt USED IN TOTAL NHHC CAl CUL ATIONS.
     10   COUCENTPATIONS JERE CALCULATED  USIN5 VALUES  OF  t FOR THE CARB3N NUMBER AND 86 MR  THE  MOLECULAR

       •   UNITS ARE EQUIVALENT TO PPH  ASSUMING A DENSITY  OF I.

-------
                   FIELD I" N":  41775                                                                     0»TE SAMPLED:   II/I6/P4
                   SAMI'LE CON1ROL NOt   4213-13                                                            DATE ANALYZED:  31/22/BO
                   SAMPLE TYPE:   nouin
                             _—			

                                                    CONCENTRATION                                                           CONCCNTRAT ) ON
            C3HPOUHP                             • N'S-C/l'l)    (HG/L)'                 CQHPOU'IO                            (N5-C/ML)    IK3/LI*

                                                                                                                                                   ca
     PARAFFINS

      •|-U!JDCC»NC                                     31.1     0.040

     tOlU AROHAIIC*

      Ii?i4-TH|HfTHYLnCN7rNC                        14.6     0.016

     T1TM. UALnSCNAiro  MC

      in iriiLOnorLOBOHflHANr                         16.0     0.205(A»
      MftllYLClIC CHLORIDC                             4.0     0.028
      CARBON Tin ACMLGP IPE                           2.0     0.026

     IINIDCMI IF ICO  VOCIC)

      IMHOEUTI PI ED V3C                                3.5     0.004
n    UNinCN'IFICD VOC                               32.9     0.039
I
*-l   ntmrFIN'.                                       34.1     0.040
     ITUL AROHATICS                                 14.6     0.01A
     T3I4L MALOSCNAICn  DC                             6.0     0.054
            IFIED  VOC                                36.4     0.043IC)
     TOTAL NMHC
                                                     91.1
                                                             0.1S4
         ARTIFACT COMPOlllin  - COMC EN1 o AT I ON  NOT  USED IN TOTAL NMHC CALCULATIONS.
      ll!»   VARIAIILC RffOVERY  T»'ROU5M DRYING SYSTEM - CONCENTRATIONS HOT  USED I •• TOTAL MHMC CALCULATIONS.
      1C)   CONCCNIRATIONS  WERE CALCULATED USINS VALUES OF 6 FOR THE CARBON  NUMBER AMD Ob FOR  THE  HOLECtlLAR UFIGHT.

        •   UNITS ART  rOUIVALFMT TO PPH ASSUMING A DENSITY OF 1 .

-------
             FIELD ID in:   MT79                                                                   DATE SAMPLED:   I I/If/M
             SAMPLE CONIROL NO:   «2IO-15                                                           DATE ANALYZED!  01/22/H5
             SAMPLE TYPE.*   LIOIMO                                                 N


                                              CONCCNTRATIOri                                                          CONCCNIPAT I ON
       COMPOUND                            INP-C/PLI    IMS/LI*                COHPOUHD                            (H5-C/ML)   IHG/LJ*
                                                                                                                                         il .
                                                                                                                                          ea


                                                2.1    0.002                                                                              JP
 C6 ALKAHT                                      2.2    0.003                                                                              Ma
 C7 ALKANE                                     69.3    O.J83
 rn ALKANE                                      1.2    o.ooi

 ILTF INS

 •>-«rTIIYL-2-BUTrNE                             17.8    0.017

 MAL HAL13ENATED HC

 TRICHLOROFLOROHCTHANC                          9.8    O.I1KAJ
 M:IMYLENE CHLORIDE                            11.6    o.os6

             vocio

              vac                               1.7    0.002
n
CO
PARAFFINS
OLEFIHS
T5TAL HALOSENATEO HC
UrjIDENl IF1ED VOC

TOTAL NMMT
 17.R
 13. b
  1.7

107.9
O.OP9
0.017
0.096
0.302ICI

0.205
 «»  APT |r ACT  COMPOUND  -  COMCCNTP AT I ON NAT ((SCO IN TOTAL NHHC CALCULATIONS.
 CPI  VARIADLf  RLCOVERV  IMRnilCM DRYISH SYSTEM - CONCENTRATIONS NOT USED  IK  TOTAL  NHHC  CALCULATIONS.
 (Cl  COIICENTRAUONS  WERE  CALCULAIEO USINS VALUES OF £ FOR THE CARBON NUMBER  AND  fib  FOR  THE  MOLECULAR
      UNITS  ARE  EQUIVALENT  TO PPH ASSUHIN3 A DENSITY OF 1.

-------
                 10  NO:   «iTfi
          •SAHPLE  CONTROL NQ:  4210-17
          s*HPtr  TYPE:    tiouir
PATE SAMPLED:   ii/is/e4
DATE ANALYZED:  02/22/85
COMPOUND
PARAFFINS
N-PF.NT ANC
N-HE«ANC
2,-S-OINETHYLHEXAHE
>t2i«-Tn IHETHYLHEXANE
CI ALKANE
C" ALKAIJf
ci ALKANE
C9 ALKAI/E
D0« ALKANE
3LCFINS
^;;;NERIMC"~PC"Tr"F
T1TAL AR3HAT1CS
9 TOLUFNf.
T3TAL HALOSCMATEO HC
TRlCHLOROFLOROHETHANr
HfTMYLENE CHLORIDE
TOTAL OXYGENATED HC»f)
ACFTOur
ISOnuTYRALDL'HYDr.
ilUTAriONT
OLCF INS
TTTAL AROKATICS
T.1TAL HALO^CNATEO MC
(At ARTIFACT COMPOUND - COKCTNTPAT
(Rl VAStACLT RtCOVcPY THROUGH D»YI
«C> CONrFNT'ATIONS VERC CALCULATED
CONCENTtATION CONCENTRATION
• NG-C/ML1 (Hli/LI* CONPUUNO (NC-C/HLI (HG/LI*
134A.O
121.0
357.0
27.4
20.5
11.4
10.2
171 .n
23.0
33.6
20.2
19.7
454.0
71. H
67.2
37. R
4.5
B35.0
16.7
52.5
44. A
2124. I
39.0
525. f
42.3
TOTAL OXYGENATED HC 948.5 l.SlSIb)
1.612 TOTAL NHHC 2732.1 3.458
0.146
0.427
0.033
O.C27
0.013
0.012
0.203
0.027-
0.011
0.040
0.024
0.022
0.49B
O.OPO
0.267
0.314
1.346
0.024
O.U79
O.OA7
2.S52
O.d46
C.578
0.2H2 |
ION NOT USTO IN TOTAL NHHC CALCULATIONS.
'IG SYSTE1 - CONCENTRATIONS IIDT USED }f TOTAL NHHC CALCULATIONS.
USINS VALUfS 'JF 6. FOR THE CARRTN NUHOfR AND R6 FOR THE MOLECULAR UEK.HT.
                                                                                                                                           2
•   UNITS ARE EOUIVALE'lT  TO PPM ASSUMI»|j A CENf-ITY  PF  1.

-------
0
                 FJfLO  10  NO:   4J7P9
                        CON1NOL NC:   42IO-1<»
                        TYPE:    LIOUIC
                                                       DATE  SAMPLED:
                                                       DATE  ANALYZED:
 11/15/84
 01/22/RS
          OHPOUNO
   CONCENTRATION
IN>>-C/ML)    IHG/L><
                                                                                 COMPOUND
   CONCENTRATION
ING-C/HL)   IHG/L)'
P.R*rFIN,
TTMANE
1 SOPfNT A>.f
UEJHLXA'il.
IS1HMANC
•"j-HfvUIL
HrTHYLCYCL3PfNTAK'E
2|4-D1HLTMYLPENTANE
CYCLOHEXAME
"-•1ETHYLHCXANE
'(-HCPTAHf
*UHYLCYCLOHEXANE
S-MfTHYLITPTANE
2»2t'»-TniMETHYLHEXANr
•1-OCTAHE
M-UQ'JANr.
'(-DECAHE
•I-UNOECAME
C6 ALKANf
C7 ALKAUr
C" ALKAMf
C<> ALKANt
C1* ALKAME
CIO* ALKANE
CIO* ALKAME
CIO* ALKAIir
Cll* ALKANE
CIC. ALK»-:r
Clfl* ALKAMf
CIO» ALKAME
TOTAL AROMATICS
ut'i?riif
I ILUCNC
rTHYLllt»l?E».C

(A) IRflFACT COMPOUND - COKCTNTRAT I Oh
mt vANiAnir nf.ctvr.fi THHOUGH DFYIMT
ICI CT ffHIlM JO'IS V'iRT CALCULA1EO US

41.1
2100.0
1B4 . 0
41.0
252 . C
1270. C
1270.6
70.1
45. B
24.7
38.6
70. P
26.9
40.4
33.7
27.4
56.3
26.5
3407.5
251.5
*66.1
43.4
61 .9
127.3
77.3
40.5
212.7
36.2
62.4
•56.9

1575.7
I'll A. 3
200. h
833. ft
.
0.060
2.527
0.220
0.049
0\i.*
• J U C
1.520
1.4R6
O.OH4
0.054
On • t
• U 3 1
0.025
0.046
O.OR3
0.032
0.054
0.040
0.033
O.U67
0.031
4.0*0
0.300
0.435
0.052
O.C74
.151
.092
.b4f>
.252
.043
.698
.367

1.709
2.103
0.722
0.9?2
NOT USED I 'I TOTAL NMI'C
SVSTC" - C3NCENTKATIONS
INI VALUES OF * FOR THE
TOTAL HALOGCNATEO HC
HETHYLENE CHLORIDE 68.3
1«1«1-TPICHLOROETHANE 19.2

TOTAL OXYGENATED HCI8»
ACETONE 3410.0
ISODUTYRALOEHYDt 396.0

UNIDENTIFIED vocio
UNIOCNTIFItO VOC 381. R
UNIDENTIFIED VOC 157.0

PARAFFINS 10429.0
TOTAL AROHATICS 4527.9
TOTAL HAL06ENATED HC XT. A
TOTAL OXYGENATED HC 3806.0
UNIDENTIFIED VOC 1138.8

TOTAL NMHC 161A3.2
.







•







CALCULATIONS.
NOT USED IN TOTAL NHHC CALCULATIONS.
C>RBON NUMBER AND «6 FOP THE MOLECULAR UEIGHT.

0.4B3
0.107


5.503
0.595


0.456
0.904

12.453
4.956
0.590
6.098(0)
1 .360ICI

19.360

















                                                                                                                                              z
       •  UNITS ARE EQUIVALENT TO PPM  AS'-UHlN'.  A  DENSITY  OF  1.

-------
FIELD 10 N"! 41TS2
SAMPLE CPNI19L fit: 421
SAMPLE TYPF: LIOUIO

c IMPOUND
PA,*FC,,,<
c-2 vnc
CVCLOPF'ITANC
J-MfTHYLPENTANC
CYCLOHCXAHE
ISOMEPUNE
rO-QIPrTMYLPENYANF
MCTHYLCYCLOHEvA^f
\.t{ THYLHEPIANE
?.2,?-TP|ir.THYLHf-»ANt
N-1CTAN1:
•J-fJ1i'll4t
M-OECANf.
H-UNDECU'E
C6 ALKA'lE
C6 ALKA'lf
C6 ALKA'JE
Cl ALKANE
C7 ALKA«E
1 C7 ALKAIIf
M C7 ALKA'Jf
C* ALKA'IT
CA ALKA'lE
C« *LKAUE
Cft ALKAMf
C" AlKA'lE
C-» ALKAHf
C *J A I, K A'*f
CO ALKA'IC
C9 ALKANL
CO ^ A L K A *J f
C-» »LKA'-r
CO 4LKA-IE
C'» ALKANT
C"> ALKAML
ci ALKANC
C9 ALKA'T
C1* ALKAHf


0-21-A

CONCfN]RATION
IN'i-C/MI.) • (HG/LI*

59.6 0.070
•540.6 9.978
53.2 • 0.064
245.9 0.2M
212.3 0.2!>3
425.1 0.507
M8.0 0.606
101.1 0.120
. 40.7 0.054
57.4 0.06A
3495.0 2.964
87.0 0.103
89.3 0.106
30.5 0.037
92.3 0.111
52. 5 0.063
984.3 1.174
1122.2 1.339
429.7 0.513
02.1 0.098
168. f 0.201
54.4 0.065
60. » 0.072
52.9 0.063
1195.0 1.420
202.4 0.240
* q Q 7 ni&QA
^»*«' U • n 7 1
814.? 0.967
1246.5 I. 491
237.7 0.282
237.7 0.2*2
f 4 n A n a A A
f ^ •! • ^ u • r p u
734.1 0.873
509.6 0.712
475.4 O.StS
73C.*> 0.660
7*1 n AQfiA
lit 1 » J Ut^Ull
49fl.l 0.592
2*>4.(, 0.349
II) APTKAC1 COKPOUND > CP» CLNTP AT 1 Cl. NOT USfH IN TOTAL 'HMMC
(III VAPIAOLC RtrOVfaV IHROUOH OfiYlwc SYSIEM - f JNCt •JfO A T IONS
1C) CO'JCf NTS AT IONS «C«E CALr.ULATEO
US INC VALUES 3F 6 FOP THL
DATE SAMPLED:
DATE ANALYZED:

11/15/84
01/29/05




CONCCNTRATION
COMPOUND
PARAFFINS ICONT'O)
CIO* ALKANC
CIO* ALKANC
CIO* ALKANC
CIO* ALKANC
CIO* ALKANC
CIO* ALKANC
CIO* ALKANC
CIO* ALKANC
CIO* ALKANC
CIO* ALKANC
CIO* ALKANC
CIO* ALKANC
CIO* ALKANC
CIO* ALKANC
CIO* ALKANC
CIO* ALKANC
CIO* ALKANC
CIO* ALKANC
CIO* ALKANC
CIO* ALKANC
CIO* ALKANE
CIO* ALKANC
CIO* ALKANC
CIO* ALKANE •

OLEFINS
1-DCCCNC
ItUNDCCFNC

TOTAL AROMATICS
OENZEWE
TOLUENE

TOTAL HALOCCNATCO HC
HCTHYLEN^ CHLORIOC.
OIBRQHQCHLOROHCTHANC
CALCULATIONS.
NOT US£0 IN T)TAL NHHC CALCULATIONS.
CAPBON NUHPEH AND fb FOR THE MOLECULAR WEIGHT.
INO-C/HL)

853.9
115.7
249.6
212.4
220.8
135.9
558.9
25.6
94.0
34.2
93.7
53.4
38.4
95.3
32.6
32.2
77.7
120.8
161.9
42.2
43.8
201.9
70.4
59.2


413.0
• 192.8


7(17.6
52'. 3


6.9
9.9


IHO/D*

1.015
0.137
0.296
0.252
0.262
0.161
0.663
0.030
0.064
0.041
G.099
0.063
0.046
0.113
O.P39
0.038
0.092
0.143
0.192
O.C50
0.052
0.239
0.063
0.070


0.4C3
0.225


O.F54
0.578


O.P4C
0.172


                                                                                                                                     n
                                                                                                                                     &
                                                                                                                                     0
                                                                                                                                     5
                                                                                                                                     z
UNITS ARE EQUIVALENT TO PPM  ASSUMING A PfMSlTY OF  1.

-------
                  riCLU 10 H*:  41792
                         CONIROL no:  42io-2i-A
                         TYPE;   i inuii;
                                            OATC
                                            OATL
                                                                                                        SAMPLED:
                                                                                                                    M/I3//I4
                                                                                                                    01/Z9/85
13TAL HAI. li


 UNIOCNi
 UK MCIH IK ico HAir>3F.«j*Tii>
                       HC «CO«I'0»


                               HC
o
I
in i uc HI I HID voc ic t

              voc
          rtro voc
          ; ir.o voc
 I'MHE'lTIf IFO VOC
        into voc
              voc
 uNinKNiirirn voc
        'IF)£0 VOC
              vac
 iif.'loruTirifO VOC
              voc
        iuro voc
           iro vor
     OLEM»'S
     111*1
     UI*t  H»fi3tN»TCn HC
     T"f»L  OKYTNAirO HC
     n'iinr»'T tr no voc
                                                    19.S
                                                    04.2
                                                            IMS/LI*
                                                                               COMPOUND
                                                              CnMCENTRATlON
                                                           INO-C/ML)    IHS/L1*
0.032
P. 264
                                                            0.3S7
.me. 2
212ft. f.
5987.4
M 06 . .Y
5IB..1
58.1
154.1
1.7
1266.2
201.4
464.3
I?J7.0
S06.1
J«PS6.ft
f.05.B
1314.1
1JO.S
231.1
1737».2
4.«iil
. 2*540
7.146
!.*AO
0.300
O.Uf.9
0.1 114
O.OU9
1.515
0.336
O.S'S
1.47A
0.366
34.161
0.70ft
1.432
0.514
O.J!U(D>
20.7S7ID
                                                 4"306.4
      '*i  Aiiif»cr cjMPounp  -  courttdPAiioi.1 NCI uscn IN IOTAL NHHC CALCOLAIIONS.
      ("i  vAciAnir Hrrovfy  T>
-------
       FICLO in N.I:  41712
       SAMPLE CONTROL NT!   421Q-21-B
       SAMPLE TYPE:   tiouic
                                                       DATE SAHPLCD:
                                                       OATC ANALYZED!
 it/is/64
 01/29/65
 COMOOIIND
   CONCENTRATION
(NG-C/HLt*  IMG/LI*
                                                                        COMPOUND
   CONCENTRATION
ING-C/HL)   (HC/L)>
PARAFMNS
c-2 vac
CYCLOnFNTANE
?.4-OIH£THYLPENT«NE
?. ,3-niTTHYLPENTANt
2t2.«-l»|H£!HYLr'CNtANE
NfTMYLCYCLOHEXA'lF
2.5-OMETHYLHEXANr
7i3,4-TRIHETHYLPENTAHE
J-MCTHYLHEPTA'lE
2i2t5-T'MHETHYLHE*AME
'1-QECANr
«J-UNDEC»NE
Ch ALKANf
C6 ALKANE
C& iLKANf
CT ALKANE
CT HKANC
CT »LKANE
r.r ALKA'ir
CT ALKA'JE
CT ALKA'IT
CT ALKA»,r
CT ALKANf.
r.« iLKAur
Cl> ALKAMf
CC Al.KA»IC
fn Ai^k*ir
C " AUK A JL
C* ALXAMT
C« »LK*«Jf
C» ALKANt
C« ALKA'IC
l*tt AlVAtJf"
1. fl • U R A * i
C« ALKAMf
C1 >LKAUt
CM ALKA'lf
C" UKANC
C9 ALK A'|T
C9 ALKA'ir
C1* AlKAHf

186.9
9602.0
83.9
126.9
T?,9
173.1
93.9
28.4
1TC..T
36.9
42.2
T90.4
. 55. 4
83.0
S6.3
131.2
186.3
513.4
1068.0
158.2
21T.7
77.0
125.9
111.)
323.5
196.9
• 9 X T
23 . f
21.1
20.8
121.1
47. ^
9 A 7
* n • r
196.6
3545.0
710.0
205.1
9 \1 *\
f 3 t • 3
3T.7
216. H

0.219
11.218
0.100
0.151
0.087
0.202
0.064
0.034
0.210
0.049
0.050
0.889
0.066
0.099
0.06T
0.157
0.222
0.612
1.2T4
0.1P9
0.260
0.093
0.1 Ml
0.132
0.365
0.234
'A A 9 ll
0 • U f O
0.026
0.025
0.144
O.J56
0/11*
• IIJ *
0.234
4.211
0.249
0.244
09 A 9
• c r c
0.945
0.25B
(A) ARTITAC1 COMPOUND - CO'lCf KTh A 11 ON NOT US(D IN TOTAL NMHC
IB) VARIAULf RtCnvrPY THROUGH PRYING SYSTEM - CONCENTRATIONS
CC» CO'ICCNTRAT IONS WERl
CALCIILAUn USING VALUES OF
6 FOR THE
PARAFFINS (CONT'OI
CIO* ALKANE
CIO* ALKANE
CIO* ALKANE
CIO* ALKANE
CIO* ALKANE
CIO* ALKANE
CIO* ALKANE •
CIO* ALKANE
CIO* ALKANE
CIO* AtKANL
CIO* ALKANE
CIO* ALKANE
CIO* ALKANE
CIO* ALKANE
CIO* ALKANE
CIO* ALKANE
CIO* ALKANE
CIO* ALKANE
CIO* ALKANC
CIO* ALKANE
CIO* ALKANE
CIO* ALKANE
CIO* ALKANE
CIO* ALKANE

OLEF1NS
T-.4-HETMYL-2-PENTENE
. 1-UNOECENC

TOTAL AROHATICS
BENZENE
TOLUENE

TOTAL HALOGENATtO HC
01BROHOCHLOROHETHANE
UNIDENTIFIED HALOSENATED HC
CALCULATIONS.
NOT USED IN TOTAL NHHC CALCULATIONS.
CARBON NUMBER AND P6 FOR THE MOLECULAR WEIGHT.

23.7
*4.3
32.6
259.3
61.0
29.9
59.1
195.6
210.4
54.6
117.7
197.5
69.9
63.8
63.9
198.7
262.0
63.3
252.6
2274.0
26*. 8
389.4
179.4
386.6


355.3
S4| .9


2fB.1
761.0


12.3
73.9



0.028
0.100
O.P39
0.307
O.OT2
0.035
O.OTO
0.2J2
0.249
0.065
0.134
0.187
0.063
0.076
0.099
0.236
0.311
0.075
0.300
2.699
0.319
0.462
0.213
0.461


0.416
0.633


0.313
O.B34


0.714
0.232


UNITS ARE EQUIVALENT TO PPM A
-------
                 rtcio 10 NO:   1179;
                 5AMPLE CONMOL  NC!   42I1-2I-B
                 SAMPLE TVPEt    LIQUID
                                                                                                  OATC SAHPLEO:
                                                                                                  DATE ANALYSED!
                                                            I1/I5/B4
                                                            01/29/85
                                                                                                                                                8
o
I
           COMPOUND


          HALPOFNATfn HC  (COUT'DI

     UNIDENTIFIED HALORtNATEO  HC

    TOTAL OXYGENATED HCIBI
     I-PROPAHOL
     I -UUTAN3L
                 VOC«CI
IINIDIMTI TIED  VOC
IINIilfNT If UD  VOC
IINIOCMI IF1EO  VOC
UNIDCNTin CO  VOC
UNIDENTIFIED  VOC
UNIOCflTIFICO  VOC
iiNior^TiriEO  vnc
UNI DLST iriCO  VOC
UNinCNTIFIED  VOC
UMinCNTlHEO  VOC
IINintNTlFlEO  VOC
UNtOfNIIFICO  VOC
UMIOtNl 1FIEO  VOC
IIN|i)rNUf IEO  VOC
UNIOINTIFIED  VOC
    OLEFI»'S
    TOTAL A«nM«HCS
    TOTAL HAL^GENATEO HC
    T.1TAL 3»YtCN»Un  HC
              ico  voc
                                             CUHCtNJRATION
                                          OIR-C/MLI   (HG/L1*
                                              34.1
                                                                             COMPOUND
                                                              CONCENTRATION
                                                           (N6-C/HLI    (HC/LI<
0.110
4324.0
767.7
29. B
31.7
49.9
3005.0
2165.0
1I1S.O
2193.0
578.3
3H1.9
954.1
508.0
20. a
237.8
311.)
182.0
503. b
2S32B.6
817,2
1C49.5
121.3
3121. 5
12238.4
7.219
1.185
0.041
0.038
0.060
3.589
2.566
1.332
2.619
0.691
0.456
1.140
0.601
0.029
0.2R4
0.372
0.218
0.601
29.102
1.049
1.147
0.5*6
e.44SIBI
14.618(0
     T1TAL
                                                39635.0    47.272
      IAI   ARTIFACT COMPOUND - CONCfNT»AT I ON NUT USED  IN  TOTAL  NHHC  CALCULATIONS.
      (Ill   VAIHABLT RtCOVfBY IHRPUSh ORYlNC SYSTE^ - CO'ICCNTH AT IONS  NOT  USfO IN TOTAL NHHC CALCULATIONS.
      in   co:irr.NTRATions UERC CAICULAIEO USINU VALUED or  t- ron  THL  CARIIJN NUHPER ANO «t FOA THE HOLECULAD WEIGHT,
        •   UNITS  ARE EQUIVALENT I1) PPM ASSI't-INf. A PENS IT Y  OF  I.

-------
n
i
                FIELD  in NO:  41*01
                SAMPLE CONTROL *ic:  *2io-25
                SAMPLE TYPCt   LIOU1P
                                                       DATC. SAMPLED:
                                                       DATE ANALYZED:
 tl/H/8*
 01/29/85
          COMPOUND
   COhCLHJRATIO'l
CNf-C/HLI    ING/LI*
                                                                                 COMPOUND
   CONCENTRATION
(NG-C/Mll   IHG/LI*
PARAFFINS
C-J VOC
CYCLOPENTANE
^-HfTMYLPFNTAME
il-HEYANE
2l4-DlltrYHVL'tENTANE
1 ^ftWTP T A UF
l*>ur*L> ' • I4b
9f J-OIMCTMYfCNf ANE
^--KTHYLMEXiNE
"ETNYLCYrLOHr.XANE
J-METHYIHTPTANE
?|2»«-TR|METHYLHEXANC
U-OCTANE
N_ u n u ft ur
— N j N * " r.
iJ-UNDCCAUF
CT ALKANE
CT ALKA'ir
fT ALKA'Jf
c» ALKANr
C« ALKAMF
C* ALKANF
C* ALKANC
P • A 1 K A IT
l> n *L^*I
CA ALKt*fl
_*• A
.9^0
.05R
.547
.925
.967
A 3 T
• * • *
.404
.353
748.7 O.AB9
287.4 0.341
105. k 0.125
47.7 0.057
240. fi 0.261,
234. q 0.276
(A) ARTIFACT C3CPOIIIIO - CONCT.NTRA1 1 0>. NOT IISfD IN TOTAL NHHC
ID) VARIABLE "£COVtPY THHOUSH ORYINC SYSTEl - C3NCLKTR AT IONS
(Cl CONfEHTRATlON^ UERE CAlfULMEtj
USIN5 VALUES OF 6 FOR THE
PARAFFINS ICONT'OI
CIO* ALKANE
CIO* ALKANE
C14« ALKANE

OLCFINS
PROPYNE
Tt4-«ETHYL-2-PENTENE
1-.OECENE
1-UNOECENC

TOTAL AROMATICS
BENZENE
TOLUENE
ETHYLBENZENE
P-XVLENr/H-XVLENE
STYRENE
NtPROPYLBENZENC

TOTAL HALOGCNATEO HC
01 BROHOCHLOROME THANE

TOTAL OXYGENATED HCIBI
1-PROPANOL
1-BUTANOL

UNIDENTIFIED VOCICI
UNIDENTIFIED VOC
UNIDENTIFIED VOC
UNIDENTIFIED VOC
UNIDENTIFIED VOC
UNIDENTIFIED V?C
UNIDENTIFIED VOC
UNIDENTIFIED VOC
UNIDENTIFIED VOC
CALCULATIONS.
NOT USED IN TOTAL NHHC CALCULATIONS.
CARBON NUMBER AND fl6 FOR THE MOLECULAR WEIGHT.

104.9
195.7
94.2


295.7
355.3
120. S
82.4


697.9
317.4
1878.5
436.7
672.8
195.3


7.2


238.3
60R.6


390.4
TO.O
3860.0
1725.0
2419.0
1117.0
792.2
520.2



0.124
0.230
0.116


• .269
0.416
0.141
0.096


0.757
0.348
2.078
0.483
0.730
0.217


0.125


0.398
0.940


0.466
0.084
4.611
2.060
2.PR9
1.334
0.946
0.621


12
'I
 2
      •  UNITS AHF EQUIVALENT TO PPM ASSUMIN3 A DENSITY OF  1.

-------
                  FIELD ID NO:  u*oi
                  SAwptt CONTROL Not  4210-25
                  SAMPLE TYPC:   LinillO
                                                       DATE SAMPLED:
                                                       DATC ANALYZED!
                                                            U/14/B4
                                                            Ol'29/aS
            C9MOOUNO
   CONCENTRATION
(Ut-C/MLI    
-------
      APPENDIX D




ANALYTICAL PROCEDURES
    D-l

-------
                              ANALYTICAL PROCEDURES

 GCA CORPORATION ANALYTICAL PROCEDURE

 GC/FID Screening of Aqueous Samples

     All of  the  aqueous  samples were screened on an HP 5890 GC/FID to  determine
 the appropriate dilution factor for subsequent GC/MS analysis.   One ul  sample
 aliquots were injected  directly into the GC/FID using the conditions  described
 in  the QA Project Plan  with the temperature program proceeding  to 230°C and
 the Helium  flow rate at about 30 ml/oxin.   The thirty-seven organic compounds
 which  were  screened by  GC/FID are shown in Table D-l.  The detection  limits
 for these compounds ranged from 1 mg/1  to 200 mg/1 owing to the variable
 response of the flame ionization detector to these compounds.
     Due to  the  large number of organic  compounds screened by GC/FID,  sample
 analyses were conducted over several days.   Subsets of the total number of
 compounds were  quantified  on each day.   Analyses were conducted on January 24
 and 28,  1985 and  February  1,  4,  13,  14,  and 15,  1985.

 GS/MS,Analvsi3

     Following the GC/FID screening,  aqueous samples were analyzed using the
 purge  and trap  method (5030 of SW-846)  for introducing the sample, or an
 appropriately diluted sample,  into the  GC/MS.
     Oil  samples were  dispersed in polyethylene glycol as described in
 Section  7.0 of  the  QA Project  Plan.   The  dispersed samples were then analyzed
 by  purge and trap GC/MS.
    A  1000 ul headspace  sample was withdrawn through the septum of each soil
 core and then injected  directly  into the  GC/MS.
    All  compounds were  identified by GC/MS  using the conditions described in
 the QA Project  Plan.  GC/MS tuning and  calibration checks were  performed as
described in the  QA Project Plan.   Qualitative identification of priority
pollutants was performed using the retention time and spectral  matches  to
                                     D-2

-------
standards.  Quantitative analysis was performed using an internal standard
method of quantitation and a three point calibration curve as described in the
QA Project Plan.  These values are reported on the Data Report Sheets
entitled: Purgeables.  Additional compounds were identified employing a
forward search of the NBS mass spectral library.  Component concentrations for
additional compounds were calculated relative to the closest eluting internal
standard.  These values, entered on Data Report Sheets entitled: Qualitative
Compounds, represent approximations due to inherent variabilities in component
response factors in the absence of reference materials.
    All data reported are blank corrected using the protocols described in the
QA Project Plan.  Detection limits are indicated on each Data Report Sheet.
    The GC/FID data for the samples reflect the ability to screen for alcohols
and ethyl aerylate.  These compounds are not amenable to purge and trap GC/MS
analysis.  Ethylene, aniline and acetonitrile were not included on the list of
targeted compounds.
    An estimation of the concentration levels of unidentified volatile organic
constituents was made for each sample.  This value was attained by comparison
of the total ion response for the entire sample GC/MS run to the response of
one internal standard.  The achieved concentration was then corrected for
blank levels, levels of surrogate and internal standards added to the sample
prior to analysis, and levels of components found in the samples.  Results of
this estimation are presented in the attached data summary tables.
    In spite of the clean-up procedures applied prior to the use of PEG, some
low level contamination of acetone and methylene chloride were noted.  Sample
results were not corrected for this contamination in order to allow the user
to evaluate the blank data.

RADIAN CORPORATION ANALYTICAL PROCEDURE

    Radian Corporation employs a gas chromatography/multiple detection (GC/MD)
method which uses three detection systems operated simultaneously.  These are
as follows:  a flame ionization detector  (FID)  to detect and quantitate
hydrocarbons, a photoionization detector  (PID)  to generate toluene -
normalized response factors, and a Hall electrolytic conductivity detector
(HECD) in the halogen mode to provide quantitation and identification of
halogenated compounds.  Detailed descriptions of the analytical  procedures
required by this method are provided in Radian  Corporation's September 23,
1984 document entitled "Protocols For Sampling  And Analysis Of  Surface
Impoundments And Landtreatment/Disposal Sites For VOCs."
                                  D-3

-------
TABLE D-l.  ORGANIC COMPOUNDS SCREENED BY GC/FID ON SAMPLES COLLECTED
Compound
1. Methanol*
2. Methylene chloride
3. Acetone
4. Trichlorofluoromethane
5. 1, 1-Dichloroe thane
6. Allyl alcohol*
7. 1, 1-Dichloroe thane
8. Trans-l,2-dichloroethene
9. Ethyl ether*
10. Chloroform *
11. 2-Butanone
12. 1,2-Dichloroethane
13. Isobutanol*
14. 1,1,1-Trichloroethane
15. Carbon tetrachloride
16. Dichlorobromomethane •
17. 1-Butanol*
18. 1,2-dichloropropane
19. Cis-l,3-dichloropropene
20. Trichloroethene
21. Benzene
Relative Retention
Time to Benzene
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
1.
079
317
342
426
466
512
551
592
612
637
678
684
764
767
790
838
859
922
942
974
00
                             (continued)
                                D-4

-------
                           "TABLE D-l.  (continued)
                                  Relative Retention
    Compound                       Time to Benzene
22. Trans-l,3-dichloropropene                         1.03

23. 1,1,2-Trichloroethane                             1.03

24. Dibromochloromethane                              1.03

25. Hexane*                                           1.10

26. Ethyl aerylate*                                   1.14

27. Bromoform                                         1.21

28. 2-Hexanone                                        1.24

29. 4-Methyl-2-pentanone                              1.34

30. 1,1,2,2-Tetrachloroethane                         1.37

31. Toluene                                           1.45

32. Chlorobenzene                                     1.53

33. Ethylbenzene                                      1.66

34. Styrene*                                          1.86

35. m-Xylene                                          1.88

36. o-Xylene                                          1.92

37. p-Xylene                                          1.99


GC Conditions:   •  HP 5890 ft. x 1/8 inch OD column packed with 1%  SP-1000
                   on 60/80 Mesh Carbopack B; Temperature Program: 60°C for 2
                   minutes, 60°C to 230°C at 10°C/min., then 230°C for 11
                   minutes; carrier gas: 36 ml Helium/minute; injector
                   temperature = 230°C.

*Area counts determined for a single concentration standard only.  All other
compounds were determined over a dilution series.
                                     D-5

-------
           APPENDIX E




RCRA PART A PERMIT PROFILE SHEET
               E-l

-------
                                    U.S. ENVIRONMENTAL PROTECTION  AGEHCY, OFFICE OF SOLID HASTE
                                                  HAZARDOUS HASTE  FACILITY PROFILE
                                PREPARED BY DEVELOPMENT PLAWING AND RESEARCH ASSOCIATES, INC. (DPRAI

                                             DATA SOURCE!  HHDM3 VERSION VI (AS OF 27DEC04)
                                FOR FACILITY! ILD006272629, AMOCO  OIL CO MAIN OFF I HATER TREATMENT
                                                                                                                     DATE!  06FEB85
                                                                                                                     PAGE!        1

                                                                                                            FACILITY! IL0006272629
 FACILITY INFORMATION
     EPA IDENTIFICATION NUMBER! XLD006272629
     FACILITY NAME*         AMOCO OIL CO MAIN OFF ft MATER TREATMENT
     MAILING ADDRESS!       P 0 BOX 102
                            MOOD RIVER
                                                                     EPA REGION!
                                                                     FACILITY OWNER»
     CONTACT PERSON/TITLE!
     CONTACT TELEPHONE!

     ACTUAL ADDRESS!
                          SUMMER RICHARD A
                          616/251-2228

                          OLD ST LOUIS RD
                          MOOD RIVER
                                                        IL  62095
                                                          IL  62095
                   OS
                   AMOCO OIL COMPANY
                   200  EAST RANDOLPH DRIVE
                   CHICAGO
                   312/856-5111
W

NJ
    FACILITY  IS A MAJOR HANDLER NOTIFIED UNDER RCRA.
    FACILITY  IS PRIVATE.
    TSOF  OWNER IS ALSO THE OPERATOR.
    EXISTING  FACILITY.
    NATURE  OF BUSINESS DESCRIPTION IS PRESENT.
    MAP IS  NOT ACCEPTABLE. DRAWING IS ACCEPTABLE.
FACILITY OPERATOR!  AMOCO OIL COMPANY
                   200 EAST RANDOLPH DRIVE
                   ?i??????mw?mwwt
                   312/856-5111
                                                                  IL 60601
                                                                  IL
                COUNTY!  119 MADISON
                LATITUDE i   38-51-05.0
                LONGITUDE!   80-05-36.0
PHOTOGRAPHS ARE NOT ACCEPTABLE.  INDIAN LANDi NO
                                      EXISTENCE! 07JAN08
                                        CLOSURE! UNKNOHN DATE
                               LAST HHDMS UPDATE! 07DEC84
 NOTIFICATION ACTIVITIES! GENERATION. TREATMENT/STORAGE/DISPOSAL.
  SIC CODES!
     (01)  2911 PETROLEUM REFINING

  DESIGN CAPACITIES!
     (01)  SOI CONTAINER
     (03)  T04 OTHER TREATMENT

  HASTES!
     U122  FORMALDEHYDE
     K048  OAF FM OILY HATER SEWER PETRO
     D001  NON-LISTED IGNITABLE HASTES
               MM FACILITY TOTAL MM
                                             (021 2869 INDUSTRIAL ORGANIC CHEMICALS.
                                        6,000.00 GALLONS.
                                        2,400.00 GALLONS/DAY.
              (021 S02 TANK STORAGE
                                  53.000.00 GALLONS.
                                            METRIC TONS MASTE PROCESSESS
                                               3.628.80
                                              49,896.00 SOI S02
                                               1,840.71 S04
                                              55,365.51
  HASTES WITHOUT AMOUNTS OR  PROCESSES!
      DOOO 0002  F001  F003-F005  F012 K049 K051-K052 P022 P053 P110 U002 U012-U013 UOI9 U044 U052 U054 U133
      U135 U140  U151  UI54 U188  U210 U220 U226 U239
  FINANCIAL DATA*
      CURRENT CLOSURE  COST ESTIMATE!
      CURRENT POST-CLOSURE COST  ESTIMATE!

  PHASE II VERIFICATION SURVEY!
      HASTE PROCESS SIZESi
      HAZARDOUS HASTE  GENERATED  IN 19811
                                             18,400. POSTED ON 22FEB84I PRIOR CLOSURE COST ESTIMATE!
                                           *102,200. POSTED ON 22FEB84I PRIOR POST-CLOSURE COST ESTIMATEl
                                                UNKNOHN TONS.

DUNS DATA!

KM INFORMATION FOR AMOCO OIL CO MAIN OFF ft MATER TREATMENT CONTINUED ON NEXT PAGE. MM

-------
                                    U.S. ENVIRONMENTAL PROTECTION AGENCY. OFFICE OF SOLID HASTE
                                                  HAZARDOUS WASTE FACILITY PROFILE                                     DATEt 06FEB85
                                PREPARED BY DEVELOPMENT PLANNING AND RESEARCH ASSOCIATES. INC.  (OPRA)                   PAGE!       2

                                             DATA SOURCE! HWDMS VERSION VI (AS OF E7DEC84)                    FACILITY: 110006272629

 DUNS DATA: (CONTINUED FROM PREVIOUS PAGE)
     SICS: 2911                                                                      STARTED:        UNKNOWN
     AMOCO OIL COMPANY INC THE           BUSINESS LINE!     PETROLEUM PRODUC         NET WORTH!     UNKNOWN
     400 S MAIN                          PRINCIPAL OFFICER! F K WEBB                 SALES!          UNKNOWN
     WOOD RIVER IL 62095                 PHONEi             618/254-7351             EMPLOYEES!          640

 M«  NOTE: END OF REPORT FOR FACILITY! UD006272629, AMOCO OIL CO MAIN OFF « MATER TREATMENT  «*
M

OJ

-------
                                   U.S. ENVIRONMENTAL PROTECTION ACENCYt OFFICE OF SOLID HASTE
                                                 HAZARDOUS WASTE FACILITY PROFILE
                                PREPARED BY DEVELOPMENT PLANNING AND RESEARCH ASSOCIATES! INC. (DPRA)

                                            DATA SOURCE( HWDM3 VERSION VI IAS OF 27DEC84)
                                FOR FACILITY:  ILD006278360, REILLY TAR ft CHEMICAL CORP
                                                                                                                 DATEl 06FEB85
                                                                                                                 PAGE!       1

                                                                                                         FACILITY: ILD006270360
 FACILITY INFORMATION
     EPA IDENTIFICATION NUMBER j  110006270360
     FACILITY NAME I          REILLY  TAR  A CHEMICAL CORP
     HAILING ADDRESSi       P 0  BOX 370
                            GRANITE CITY
                                                                 EPA REGION:
                                                                 FACILITY OWNERt
CONTACT PERSON/TITLE:
CONTACT TELEPHONE:

ACTUAL ADDRESS:
                            PIRTLE LARRY L PLANT MGR
                            19TH I EDMARDSVILLE RD
                            GRANITE CITY
                                                     IL  62040
                                                     IL  62040
                    05
                    REILLY TAR I CHEMICAL CORPORATION
                    151 NORTH DELAWARE STREET
                    INDIANAPOLIS
                    317/638-7531
                   IN 46204
PI
FACILITY IS A MAJOR HANDLER NOTIFIED WIDER RCRA.
FACILITY IS PRIVATE.
TSDF OWNER IS ALSO THE OPERATOR.
EXISTING FACILITY.
NATURE OF BUSINESS DESCRIPTION IS PRESENT.
MAP IS ACCEPTABLE.     DRAWING IS ACCEPTABLE.
  FACILITY OPERATOR: REILLY TAR ft CHEMICAL CORPORATION
                    151 NORTH DELAWARE STREET
                    mm????7i?m?t?mm       IN 7777?
                    317/638-7531
  COUNTY:  119  MADISON
  LATITUDE :   38-41-20.0
  LONGITUDE:   80-08-20.0
        EXISTENCE:  09SEP76
          CLOSURE:  UNKNOWN DATE
LAST HWDMS UPDATE:  26NOV84
                                                       PHOTOGRAPHS ARE ACCEPTABLE.
                  INDIAN  LAND: NO
 NOTIFICATION ACTIVITIES: GENERATION.  TREATMENT/STORAGE/DISPOSAL.
 SIC CODES:
     (OH 2865 CYCLIC CRUDES AND INTERMEDIATE
 DESIGN CAPACITIES:
     (Oil SOI CONTAINER
     (03) S03 WASTE PILE
     (05) T02 SURFACE IMPOUNDMENT
                                       110.00 GALLONS.
                                     1*106.00 CUBIC YARDS.
                                    30.000.00 GALLONS/DAY.
(021 S02 TANK STORAGE
(04) T01 TANK TREATMENT
(06) T03 INCINERATOR
   71,000.00 GALLONS.
   30.000.00 GALLONS/DAY.
        0.32 METRIC TONS/HOUR.
 HASTES:
     U239 XYLENE
     U226 1.1.1-TRICHLOROMETHANE »
     U220 TOLUENE
     U188 PHENOL OR CARBOLIC ACID.HYDROX
     U151 MERCURY
     U112 ETHYL ACETATE (I)
     U051 CRESOTE
     U002 ACETONE (I)
     POOS 4-AHINOPYRIDINE OR AVITROL.PHI
     K035 TREAT SLUDGES FM PROO CREOSOTE
               «» FACILITY TOTAL **

 WASTES WITHOUT AMOUNTS OR PROCESSES:
     0001 U013

 FINANCIAL DATA:
     CURRENT CLOSURE COST ESTIMATE:
     CURRENT POST-CLOSURE COST ESTIMATE:
                                         METRIC TONS WASTE PROCESSESS
                                                0.02 T03
                                                0,02 T03
                                                0.00 SOI
                                                0.00 T03
                                                0.00 SOI
                                                0.01 T03
                                              453.60 T03
                                                0.00 T03
                                                0.00 T03
                                                1.36 S02
                                              455.02
                                     t2.14I.000. POSTED ON 22FEB84I PRIOR CLOSURE COST ESTIMATE:      *1,600,000.
                                       tieO.OOO. POSTED ON 22FEB84I PRIOR POST-CLOSURE COST ESTIMATE:   1180,000.
  **  INFORMATION  FOR REILLY TAR ft CHEMICAL CORP CONTINUED ON NEXT PAGE. «M

-------
                                    U.S.  ENVIRONMENTAL PROTECTION AGENCY, OFFICE OF SOLID WASTE
                                                  HAZARDOUS HASTE FACILITY PROFILE
                                PREPARED  BY DEVELOPMENT PLANNING AND RESEARCH ASSOCIATES, INC. (DPPA)

                                             DATA SOURCE! HUDMS VERSION VI (AS OF 270ECB4)
                                                                              DATEI 06FEB85
                                                                              PAGEI       2

                                                                     FACILITY! ILD006278360
 FINANCIAL DATAl  (CONTINUED FROM PREVIOUS PAGE)
     ASSURANCE INSTRUMENT LETTER OF EFFECTIVE  ON UNKNOWN DATE.  EXPIRES ON  16JAN84.
       THE INSTRUMENT NUMBER IS UNKNOWN AND THE  INSTRUMENT COVERS ONE FACILITY.
     LIABILITY INSTRUMENT FINANCIAL EFFECTIVE  ON UNKNOMN DATE,  EXPIRES ON  30MAR84.
       THE INSTRUMENT NUMBER IS UNKNOWN AND THE  INSTRUMENT COVERS ONE FACILITY.

 PHASE II VERIFICATION SURVEY!
     HASTE PROCESS SIZES!
          SURFACE IMPOUNDMENTS!         30,000.00 SQUARE YARDS.
          HASTE PILES:                    UNKNOWN CUBIC YARDS.
          STORAGE CONTAINERS!              175.00 GALLONS.
     THIS FACILITY MAS A TSD OR GENERATOR IN 1981.
     HAZARDOUS HASTE GENERATED  IN 1981:              8.00  TONS.
     THIS SITE DID NOT RECEIVE  HAZARDOUS HASTES  GENERATED  BY OTHER  FIRMS.
 DUNS DATA:
     SICS: 2665
     REILLY TAR t CHEMICAL CORP
     19TH I EDUARDSVILLE RD
     GRANITE CITY IL 62040
BUSINESS LINE:     COAL TAR REFINER
PRINCIPAL OFFICER: KENNETH J MORRISON
PHONE:             618/452-3141
                                           STATUS  ON THIS  INSTRUMENT IS ACTIVE.

                                           STATUS  ON THIS  INSTRUMENT IS ACTIVE.
STARTED:
NET WORTH:
SALES:
EMPLOYEES:
UNKNOWN
UNKNOWN
UNKNOWN
     70
 «»  NOTE: END OF REPORT FOR FACILITY:  110006278360,  REILLY TAR  t CHEMICAL CORP  MM
PI

-------
                                    U.S. ENVIRONMENTAL PROTECTION AGENCY* OFFICE til  >ciUo
                                                  HAZARDOUS HASTE FACILITY PROFILE
                                 PREPARED BY DEVELOPMENT PLANNING AMI) RESEARCH ASSOCIATES, IN*   (DPRA)

                                             DATA SOURCE I HHDMS VERSION VI lAS ul- 2/UtLfi^l
                                 FOR FACILITY:  ILD080012305, SHELL OIL CO MOOD RIVER REFINERY
                                                                                                                 DATES  06FEB85
                                                                                                                 PAGE!        1

                                                                                                        FACILITY: ILD080012305
FACILITY INFORMATION
EPA IDENTIFICATION
FACILITY NAME:
MAILING ADDRESS:



NUMBER I XLD080012305
SHELL OIL CO MOOD
PO BOX 262
MOOD RIVER



RIVER REFINERY

IL 62095


EPA REGION:
FACILITY OWNER:




OS
SHELL OIL CO
PO BOX 262
MOOD RIVER
616/254-7371




XL 62095

      CONTACT PERSON/TITLE:
      CONTACT TELEPHONE:

      ACTUAL ADDRESS:
                       MALLS CG MGR ENV CONSERV
                       618/254-7371

                       SA MA ft RTC 111
                       ROXANA
                                 FACILITY OPERATOR:
                                                           IL  62084
SHELL OIL CO
PO BOX 262
m?mmmtw»?wm
618/254-7371
                                                                                   IL TWt
W
FACILITY IS A MAJOR HANDLER NOTIFIED UNDER RCRA.
FACILITY IS PRIVATE.
TSDF OWNER IS ALSO THE OPERATOR.
EXISTING FACILITY.
NATURE OF BUSINESS DESCRIPTION IS PRESENT.
MAP IS ACCEPTABLE.     ORAUING IS ACCEPTABLE.     PHOTOGRAPHS ARE NOT ACCEPTABLE. INDIAN LAND:  NO
                                                                       COUNTY: 119  MADISON
                                                                       LATITUDE :  38-50-42.0
                                                                       LONGITUDE:  90-02-59.0
                                                                        EXISTENCE: 01JAN18
                                                                          CLOSURE: UNKNOWN DATE
                                                                LAST HMDMS UPDATE: 07DEC84
  NOTIFICATION ACTIVITIES: GENERATION. TRANSPORTATION.  TREATMENT/STORAGE/DISPOSAL.

      TRANSPORTATION MODE(S): HIGHWAY.
  SIC COOES:
      (01) 2869 INDUSTRIAL ORGANIC CHEMICALS,
  DESIGN CAPACITIES:
       (01) 003 SURFACE IMPOUNDMENT
       (03) S02 TANK STORAGE
                                          102)  2911 PETROLEUM REFINING


                                                               (02) SOI CONTAINER
40,000,000.00 GALLONS.
   600,000.00 GALLONS.
                5,000.00 GALLONS.
   WASTES:
       U16B  PHENOL OR CARBOLIC ACID.HYDROX
       U019  BENZENE
       K052  BOTTOMS  (LEADED) FM PETRO REFI
       K051  API  SLUDGE FM API OILY SEWER P
       K050  PETRO REFIN EXC BUNDLE CLEANIN
       K049  SLOP OIL FM OILY MATER SEHER P
       K048  OAF  FM OILY MATER SEWER PETRO
       F003  NON-HALOGENATED SOLV i SOLV RE
       F001  SPENT HALO CHLORIDES I SLUDGE
       D003  NON-LISTED REACTIVE WASTES
       D002  NON-LISTED CORROSIVE MASTRES
                MM  FACILITY TOTAL MM

   HASTES WITHOUT AMOUNTS OR PROCESSES:
       DOOO-D001 P110 U013

   FINANCIAL DATA:
       CURRENT CLOSURE COST ESTIMATE:
       CURRENT POST-CLOSURE COST ESTIMATE:
                                         METRIC  TONS HASTE PROCESSESS
                                                4.54 SOI
                                                0.91 301
                                                4.54 SOI
                                            9,072.00 D83
                                                4.54 SOI
                                            2,721.60 D83
                                            1,814.40 DB3
                                                0.91 SOI
                                                0.91 SOI
                                              825.55 SOI  304
                                            6,350.40 802
                                           20,800.28
                                       *415,000. POSTED ON 22FEB84I  PRIOR CLOSURE COST ESTIMATE:
                                         16,300. POSTED ON 22FEBQ4I  PRIOR POST-CLOSURE COST ESTIMATE:
                                                                       1415,000.
                                                                         «6,300.
      INFORMATION FOR  SHELL OIL CO HOOD RIVER REFINERY CONTINUED ON NEXT PAGE.  MM

-------
                                    U.S. ENVIRONMENTAL PROTECTION AGENCYi  OFFICE OF SOLID WASTE
                                                  HAZARDOUS HASTE FACILITY PROFILE
                                PREPARED BY DEVELOPMENT PLANNING AND RESEARCH ASSOCIATES, INC. (DPRA)

                                             DATA SOURCE! HWDM3 VERSION VI (AS OF 27DEC84)
                                                                              DATE: 06FEB65
                                                                              PAGE:       2

                                                                     FACILITY! ILD080012305
 FINANCIAL DATA! (CONTINUED FROM PREVIOUS PAGE)
     ASSURANCE INSTRUMENT FINANCIAL EFFECTIVE ON UNKNOWN DATE, EXPIRES ON 31HAR84.   STATUS ON THIS INSTRUMENT IS ACTIVE.
       THE INSTRUMENT NUMBER IS UNKNOUN AND THE INSTRUMENT COVERS ONE FACILITY.
     LIABILITY INSTRUMENT FINANCIAL EFFECTIVE ON UNKNOUN DATE, EXPIRES ON 31MAR84.   STATUS ON THIS INSTRUMENT IS ACTIVE.
       THE INSTRUMENT NUMBER IS UNKNOUN AND THE INSTRUMENT COVERS ONE FACILITY.
 PHASE II VERIFICATION SURVEY!
     HASTE PROCESS SIZES:
     HAZARDOUS HASTE GENERATED IN 1981I

 DUNS DATA:
     SICS: 2911
     SHELL OIL COMPANY
     JCT HMY 111 t 143
     ROXANA IL 62084
         UNKNOUN TONS.
BUSINESS LINE!
PRINCIPAL OFFICER!
PHONE:
REFINERY
A R MILLIAMS
618/254-7371
STARTED!
NET WORTH:
SALES:
EMPLOYEES:
UNKNOUN
UNKNOUN
UNKNOUN
  1,700
 «»  NOTE: END OF REPORT FOR FACILITY! ILD080012305, SHELL OIL CO MOOD RIVER REFINERY  «»
M
I

-------
  FORM

    3
  RCRA
              EPA
                                    U.S. ENVIRONMENTAL. PROTECTION ACCNCY •
                               HAZARDOUS WASTE PERMIT APPLICATION
                                             Consolidated Permit! Program
                                 (Thit information it required under Srelion 3003 of RCRA.)
                                                                                              EPA I.D.
                                                              F  I
 FOR OFFICIAL USE ONLY
APPLICATION
 >PPROVCO
                             3£S€g3$@f&&€S£3£IS^^
                OATCRCCCIVEO
                fyr. mo., f day)
                                                                            COMMENTS
 II. FIRST OR REVISED APPLICATION
 Place in "X" in the appropriate box in A or 8 below (mark one box only) to indicate whether this is the first application you are submitting for your facility o
 revised application. If this is your first application and you already know your facility's EPA I.O. Number, or if this is a revised application, enter your facility's
 EPA 1.0. Number in Item I above.
 A. FIRST APPLICATION (place on "X" btlou and provide tht appropriate date)
      [531. EXISTING FACILITY (Stt instructions for definition of "ffitting" faeiUty.
      11     .                  Complete item below.)
                     18
                         FOR EXISTING FACILITIES. PROVIDE THE DATE (yr.. mo.. A day)
                         OPERATION BEGAN OR THE DATE CONSTRUCTION COMMENCED
                         fuse the boitt to tht left)
                                                                                            ]2.NEW FACILITY (Complete Htm below.)
                                                                                                               FOR NEW FACILITIt
                                                                                                               PROVIDE THE DATE
                                                                                                               (yr.. mo., A day) OPEH
                                                                                                               TION BEGAN OR IS
                                                                                                               EXPECTED TO BEGI
 B. REVISED APPLICATION (place on A  below and complete Item I above)

      r"5«- FACILITY HAS INTERIM STATUS
                                                                                                 FACILITY MAS A RCRA PERMIT
 III. PROCESSES - CODES AND DESIGN CAPACITIES ^Ig^^^^^^^»^CJ
 A, PROCESS CODE — Enter the code from the list of process codes below that best describes each process to be used at the facility. Ten lines are provided for
    entering codes. If more lines are needed, enter the cotie(s) in the space provided. If a process will be used that is not included in the list of codes below, the:
    describe the process (including la design capacity) in the space provided on the form (Item III-CI.

 B. PROCESS DESIGN CAPACITY — For each code entered in column A enter the capacity of the process.
    t. AMOUNT — Enter the amount.
    2. UNIT OF MEASURE — For each amount entered in column Bill, enter the code from the list of unit measure codes below that describes the unit of
      measure used. Only the units of measure that are listed below should be used.
           PROCESS
                             PRO-   APPROPRIATE UNITS OF
                             CESS   MEASURE FOR PROCESS
                             CODE      DESIGN CAPACITY
                                                                                                    PRO-
                                                                                                    CESS
                                                                              PROCESS
                                                                                                         APPROPRIATE UNITS OF
                                                                                                         MEASURE FOR PROCESS
                                                                                                                   CAPACITY
Storage:
CONTAINER (barrel, drum, etc.)
TANK
WASTE PILE

SURFACE IMPOUNDMENT
SOI   GALLONS OR LITERS
502   GALLONS OR LITERS
SO3   CUBIC YARDS OR
      CUBIC METERS
S04   GALLONS OR LITERS
                                                                    Treatment:

                                                                    TANK

                                                                    SURFACE IMPOUNDMENT

                                                                    INCINERATOR
                                                                                                   TO I  GALLONS PER DAY OR
                                                                                                        LITERS PER DAY
                                                                                                   T02  GALLONS PER DAY OR
                                                                                                        LITERS PER DAY
                                                                                                   T03  TONS PER HOUR OR
                                                                                                        METRIC TONS PER HOUR:
                                                                                                        GALLONS PER HOUR OR
                                                                                                        LITERS PER HOUR
LANDFILL D»0 ACRE-FEET (the volume that OTHER (Ute for physical, chemical. T04 GALLONS PER DAY OR
would cover one acre to a thermal or biolofical treatment LITERS PER DAY
depth of one foot) OR processes not occurrinf in tanks.
HECTARE-METER surface impoundments or inciner-
LAND APPLICATION D*1 ACRES OR HECTARES atorx. Describe the practise* in
OCEAN DISPOSAL O«2 GALLONS PER DAY OR the space provided: Item ai-C.)
LITERS PER DAY
SURFACE IMPOUNDMENT Dt3 GALLONS OR LITERS
UNIT OF UNIT OF UNIT
MEASURE MEASURE MEASl
UNIT OF MEASURE CODE UNIT OF MEASURE CODE UNIT OF MEASURE COD
GALLONS 	 G
LITERS
CUBIC 1
CUBIC K
GALLOI
EXAMPLE
other can 1


IET
IS 1
:FC
10lC
t (
c]


}R COMPLETING ITEM III (tho
400 gallons. The facility also ha
• T*A
DUP
t 1 > • tilt-
LINE
NUMOER
X-1
X-2
1
-
3
4
1
A. PRO-
CESS
CODE
(from list
above)
n - i»
s
T
5
S
T

0
0
C
0
0

2
3
1
3
2

B. PROCESS DESIGN
LITERS PER DAY
TONS PER HOUR
METRIC TONS PE
GALLONS PER HC
LITERS PER MOU
wn in line numbers X- 1 and X
s an incinerator that can burn
c \ N
1 \
• ~ \
. . . . V ACRE-FEET . t

R H
JUF
B
OUR
»




2 below): A facility has two storage tanks, one tank can hold 200 gallons and t
up to 20 gallons per hour.
\\x\\\\\\\\\\\\\\\\\\
CAPACITY
t. AMOUNT
(specify;
f* *
600


20
660
500
40,000
i» - i*
2. UNIT
OF MEA-
SURE
(enter
code)






G
E
G
Y
U
T«






FOR
OFFICIAL
USE
ONLY
f» - »i





t»

















jt
LINE
NUMBER

5
6
7
8
9
10
A. PRO-
CESS
CODE
(from list
above;
t» - «•





• •











i»
B. PROCESS DESIGN CAPACITY
t. AMOUNT
!• - Z»





«» - !»
2. UNIT
OF MEA-
SURE
(enter
code)






>•





rt






FO
OFFK
US
ON
H •





?•






EPA Form 2510-3 16-80)
                                                            PAGE  1  OF 5
                                                                  « ...e  n —.
                                                                                                   E-8
                                                                                                              CONTINUE ON RHVc
                                                                                     1 _TO_O/.

-------
111. PROCESSES (continued)

C. SPACE FOR ADDITIONAL PROCESS CODES OR FOR DESCRIBING OTHCR PROCESSES (code "T04"). FOR EACH PROCESS ENTERED HERE
  JNOUUDE DESIGN CAPACITY.
 IV. DESCRIPTION OF HAZARDOUS WASTES >S*^
   *     -~*-~~  -.•^«	^ » .*« .  j»****• ^* VW • •«-» M « ^h* ^^.^Tl^V^^^*--'-^^*v*'gi.'.^^-"g^:r"j*> <~ ^ry^^—c-•St1-*,*f>J5'=^'«":"^—i"t**r"^'r*'VJtTi~~<^"'^i*fc'T'''a'^"^'•a^r-^?>^^M-~'~*'•* =—^^1—^^^-
A. EPA HAZARDOUS WASTE NUMBER —.Enter the four-aigrt numoer trom 40 CFfiTSubpart^0 tor each listed hazardous waste you will1 handle. If you
   handle hazardous wastes which are not listed in 40 CFR. Subpart D. enter the four—digit numberW from 40 CFR. Subpart C that describes the characteris-
  * tics and/or the toxic contaminants "of those hazardous wastes.

B. ESTIMATED ANNUAL QUANTITY — For each listed waste entered in column A estimate the quantity of that waste that will be handled on an annual
   basis. For each characteristic or toxic contaminant entered in column A estimate the total annual quantity of all the non—listed wastefo/ that will be handled
   which possess that characteristic or contaminant.

C. UNIT OF MEASURE — For each quantity  entered in column B enter the unit of measure code. Units of measure which must be used and the appropriate
   codes are:
                ENGLISH UNIT OF MEASURE
                                                                               METRIC UN IT QFJAEASUHE^
                                                             CODE.
                POUNDS.
                TONS. . .
.f
.T
KILOGRAMS..
METRIC TONS.
,K
. M
    If facility records use any other unit of measure for quantity, the units of measure must be converted into one of the required units of measure talcing into
    account the appropriate density or specific gravity of the waste.

D.  PROCESSES
    1. PROCESS COOES:
      For listed hazardous wast*:  For each listed hazardous waste entered in column A select the coded) from the list of process codes contained in Item III
      to indicate how the waste will be stored, treated, and/or disposed of at the facility.
      For non—fisted hazardous wastes:  For each characteristic or toxic contaminant entered in column A, select the codefil from the list of process codes
      contained in Item III to indicate all the processes that will be used to store, treat, and/or dispose of all the non—listed hazardous wastes that poses
      that characteristic or toxic contaminant.
      Nota:   Four spaces are provided for entering process codes. If more are needed: (1) Enter the first  three as described above; (2) Enter "OCX)"  in the
      extreme right box of Item IV-Q(I); and (3) Enter in the space provided on page 4, the line number and the additional codefrj.

    2. PROCESS DESCRIPTION:  If a code is not listed for a process that will be used, describe the process in the space provided on the form.

NOTE:  HAZARDOUS WASTES DESCRIBED BY MORE THAN ONE EPA HAZARDOUS WASTE NUMBER - Hazardous wastes that can be described by
more than one EPA Hazardous Waste Number shall be described on the form as follows:
    1. Select one of the EPA Hazardous Waste Numbers and enter it in column A. On the same line complete columns B.C. and O by estimating the total annual
      quantity of the waste and describing all the processes to be used to treat, store, and/or dispose of the waste.
    2. In column A of the next line enter the other EPA Hazardous Waste Number that can be used to describe the waste. In column D(2) on that line enter
      "included with above" and make no other entries on that line.
    3. Repeat step 2 for each other EPA Hazardous Waste Number that can be used to describe the hazardous waste.

EXAMPLE FOR COMPLETING ITEM IV (shown in line numben X-1. X-2, X-3. and X-4 below} - A facility will treat and dispose of an estimated 900 pounds
per year of chrome shavings from leather tanning and finishing operation. In addition, the facility will treat and dispose of three non—listed wastes. Two  wastes
are corrosive only and there will be an estimated 200 pounds per year of each  waste. The other waste is corrosive and ignitable and there will be an estimated
100 pounds per year of that waste. Treatment will be in an incinerator and disposal will be in a landfill.
u
So
_1Z
X-1
%
J .
X-3
X-4
A. EPA
HAZARD.
WASTENO
(enter code)
K
D
D
D
0
0
0
0
5
0
0
0
4
2
1
2
B. ESTIMATED ANNUAL,
QUANTITY OF WASTE
900
400
100

C. UNIT
OF MEA-
SURE
(enter
code)




P
P
P





D. PROCESSES
t. PROCESS COOES
(enter)
1 J~
T 0 3
\ \
T 0 3
i J
T 0 3
\ i
i i
D 8 0
i i
D 8 0
D 8 0
i i
i i
i i
i *
i i
i i
i i
i i
i i
Z. PROCESS DESCRIPTION
(If a code it not entered in DID)



included with above
EPA Form 3510-3 16-80)
                                                                 PAGE 2 OF 5
                                                                         A—7    Revi
                               11-28-84
                                                 E-9
                                                                                                                           CONTINUE ON PAG

-------
Continued front page 2.
NOTE: Photocopy this p»or before completing if you have more than 26 wastts to list
Form Approved OMB No. 1S8-S80OO4
EPA 1.0. NUMBER fcnlcr from paftf 1)
•
w
•
1
L
D
0
0
62783
6
0
s - *•
T/A

f •
C
1
1*
\ \ \

*
W

row orriciAi. use ONUY \ \ \ \ \ \ \
DUP
U£ * 	 \ \ \ \ \ \ »•
_J-2 DUP \\\\\\\

— DESCRIPTION OF HAZARDOUS WASTES (continued) "^^5 ?£* ^^^Jfc2^£3^^>:^
u
Ed
1
2
3
4
5
6
7
8
9
10
1
1
1
fe
13
14
15
16
17
18
19
20
21
22
23

25
26
A. EPA
HAZARD.
WASTE NO
(enter code)
L
K























M
0
0
























5
3
























1
5























>• i
B. ESTIMATED ANNUAL
QUANTITY OF WASTE
500
6,600





-



*





•








C. UNIT
OrMEA-
SURE
f enter
code)


























JX
T
P


















































D. PROCESSES
1. PROCESS COOKS
(tnlrrl
l I
S 0 3
S



0 1



»
i i
i <
i i

i i
i i



i
i
i
i
i i
i
l
i
i
i i
i
l
i
i


i i
i i


i >
i i


i i
i i
i i



• i
i i
i i
i i
i i
i i
i i
i <
i i
i i
i i
i i
i i
i i


i i
i —i


i f
• i
• t



• i
i i
< i
i i
i i
i i
i i
i i
i i
i i
i i
i i
i i
" - >•
i *


I »




1 l




1 1
t 1
1 1
t 1
1 1
t 1
t t
« i
i i -
I *
t 1
i 1
i i
Z. PROCESS DESCRIPTION
(If a code U not entered in D(l))
Off Site Disposal
Off Site Disposal
























EPA Form 2570-3 (5-801
                                                                A-8  Revised 11-28-84
                                                     PAGE 3 	OF 5
     E-10
                                                                                                           CONTINUE ON REVEF

-------
Continued from the Iront.
IV. DESCRIPTION OF HAZARDOUS WASTES (contir.uedl ^^^$$ J^^^lf^
  •  — — i - -  - - —^-	._ _ ™" ™ ^* •••«** »*»»ji|^^«»»**»»*to/ i^r ^~¥i ^^^v *  — -•• ^**^~ •*^«, • v\ t\"^y •• " % j
 E. USE'THIS SPACE TO LIST ADDITIONAL PROCESS COOES FROM ITEM D(l J ON PACE 3.
      EPA I.O. NO. (eater from page 1)
 V. FACILITY DRAWING
 All ex'cting facilities must indude in the space provided on pace 5 a scale drawing of the facility (see instructions for more detail!.
 VI. PHOTOGRAPHS JS^J^gl^^?^^^^^
 AH existing facilities must indude photographs (aerial or ground— level) that dearly delineate all existing structures; existing storage.
 treatment and disposal areas; and sites of future storage, treatment or disposal areas (see instructions for more detail}.
                                                                                                           _   _
     FACILITY GEOGRAPHIC LOCATION ^:«^Sg^g^^45J:5?r^^^^
               LATITUDE fdttrtr*. minute*. £ ttcondt)
                                                                                LONGITUDE tdtgrret. minutet. ti seconds)
                         3 8
                               4  1
020
090
0  8
020
VIII. FACILITY
                                                              ^3^^
       If the facility owner a also th« facility operator as lined in Section VIII on Form 1. "General Information", place an ~X~ in the box to the left and
       ikip to Section IX below.

     B. If the facility owner is not the facility operator as lined in Section VIII on Form 1. complete the following items:
                                1. NAME OF FACILITY'S LEGAL. OWNER
                                                                                                      2. PHONE NO. (ana code & nt
E!
                S. STREET OR P.O. BOX
                                                                    4. CITY OR TOWN
                                                                                                  S.ST.
                                                                                                                C. ZIP COOE
F!
                                                      C 1
                                                      Gl
 IX. OWNER CERTIFICAT10N ^IV^S^^^^^^^Sg^^-r^^r^^^^^^gr^H^
 / certify under penalty of law that I have personally examined and am familiar with the information submitted in this and all attached
 documents, and that based on my inquiry of those individuals immediately responsible for obtaining the information, I believe that the
 submitted information is true, accurate, and complete, I am aware that there are significant penalties for submitting false information,
 including the possibility of fine and imprisonment.
 A. NAME (print or type)
    C.  F.  Lesher
    Executive Vice  President
                                                  B. SW-HATUR
                                                                                                   C, DATE SICNEO
 X. OPERATOR CERTIFICATION

    tify under penalty offaw that I have personally examined and am familiar with the information submitted in this and all attached
•I	uments. and that bzssd on my inquiry of those Individuals immediately responsible for obtaining the information, I believe that the
 submitted information is true, accurate, and complete. I am aware that there are significant penalties for submitting false information,
 including the possibility of fine and imprisonment.
 A. NAME (print or type]
                                                  8. SIGNATURE
                                                                                                    C. DATE SICNEO
                                                                                                               CONTINUE ON P;

-------