HIGH ALTITUDE VEHICULAR EMISSION CONTROL PROGRAM
VOLUME Vl-A. THE DATA BASE: IDLE EMISSIONS
INSPECTION IN THE PRIVATE SECTOR
PREPARED FOR:
STATE OF COLORADO
DEPARTMENT OF HEALTH
DENVER, COLORADO 80220
/automotive
ATL/ testing
-------
HjGH ALTITUDE VEHICULAR EMISSION CONTROL PROGRAM
' * £%
VOLUTVIE Vl-A. THE DATA base: IDLE EMISSIONS l-t'b
INSPECTION IN THE PRIVATE SECTOR;
EXHAUST CONTROL- RETROFIT;
MODIFIED TUNING SPECIFICATIONS;
MANDATORY ENGINE MAINTENANCE
PREPARED FOR:
STATE OF COLORADO
DEPARTMENT OF HEALTH
DENVER, COLORADO 80220
/AUTOMOTIVE
TESTING
-------
Disclaimer
This report was furnished to the Colorado Air Pollution Control Commission
by Automotive Testing laboratories, Inc. in fulfillment of Contract
No. C290526 and the Environmental Protection Agency, Region VIII, Contract
No. 68-02-0048, Task Order 22. The contents of this report are repro-
duced herein as received from the contractor. The opinions, findings
and conclusions expressed are those of the authors and not necessarily
those of the Air Pollution Control Commission. Mention of company or
product names is not considered as an endorsement by the Colorado Air
Pollution Control Commission.
-------
PREFACE
This report is the sixth of a seven volume report prepared for
the State of Colorado, Department of Health and the Environmental
Protection Agency, Region VIII. The title of each respective volume
is as follows:
Volume I Executive Summary
Volume II Experimental Characterization of Idle Inspection, Exhaust
Control Retrofit and Mandatory Engine Maintenance
Volume III Impact of Altitude on Vehicular Exhaust Emissions
Volume IV Analysis of Experimental Results
Volume V Development of Techniques, Criteria, and Standards to
Implement a Vehicle Inspection, Maintenance and Modification
Program
Volume VI The Data Base
Volume VII Experimental Characterization of Vehicular Emission and
Engine Deterioration
These reports describe the design, conduct, findings and conclusions
of study programs Initiated in compliance with the requirements of the
Colorado Department of Health and the Environmental Protection Agency.
Volume VI is comprised of data from the experimental program designed
to Investigate several elements of emission control; idle emission
inspection, exhaust control retrofit, modified engine tuning specifi-
cations and mandatory engine maintenance.
-------
SUMMARY
A sample of 300 of the 1964 through 1973 model-year vehicles was
utilized to Investigate the effectiveness and feasibility of several
exhaust emission control strategies as might be applied In the Colorado
environment. Four strategies were evaluated; Idle emissions Inspection
In the private sector, exhaust control retrofit, modified engine tuning
specifications, and mandatory engine maintenance.
A further sample of 153 of the 1964 through 1973 model-year vehicles
was utilized to investigate the effects of altitude on vehicular
emissions. The evaluation of altitude effects was accomplished by
combining data from the 153 vehicle sample at 10,000 feet, the 300
vehicle sample at 5500 feet, and from a previously conducted test
program at 600 feet Incorporating a 180 vehicle sample.
An additional evaluation of deterioration of reductions achieved
in the Inspection and maintenance program as a function of time was
undertaken. This was accomplished by retesting of vehicles used in
the Inspection and maintenance evaluation at known time intervals.
The various programs are fully discussed in other volumes of
this report. The data base resulting from the testing program is
presented in this volume as follows.
The idle Inspection data base is presented in volume VI A.
Volume VI B contains the data base for the retrofit evaluation, and
modified tuning specifications. The data bases of the altitude effects
testing program and the deterioration study are in volume VI C.
-------
TABLE OF CONTENTS
Page
1. INTRODUCTION 1
2. DATA REDUCTION 3
2.1 EMISSION TESTS 3
2.1.1 Federal Test Procedure 3
2.1.2 Key Mode Test Procedure 4
2.1.3 Idle Test Procedure 4
2.2 VEHICLE MAINTENANCE STATUS INSPECTION 5
2.3 IDLE INSPECTION AND MAINTENANCE 5
3. INSPECTION AND MAINTENANCE EVALUATION DATA 6
3.1 HEADING 6
3.2 MAINTENANCE STATUS 6
3.3 IDLE INSPECTION 7
3.4 AS RECEIVED FROM OWNER 8
3.4.1 Federal Test Procedure 9
3.4.2 Key Mode Test Procedure 9
3.4.3 Idle Test Procedure 9
3.5 AS RECEIVED FROM INSPECTION 10
4. LISTING OF DATA LI
5. APPENDICES 312
-------
1. INTRODUCTION
Colorado was required to submit plans by April 15, 1973 that
contain control strategies demonstrating how ambient air quality
standards would be achieved by 1975 in the Metropolitan Denver Air
Quality Control region. In response, the State of Colorado, Department
of Health submitted the State of Colorado Air Pollution Control Trans-
portation and Land Use Plan, dated May 14, 1973.
In order to deal with air pollution problems caused by mobile
sources, the Colorado Legislature, in June of 1973, passed Senate Bill
393. The bill directed the Colorado Health Department to investigate
several emission control strategies. Automotive Testing Laboratories,
Inc. was selected by the state to provide testing and other consulting
services to experimentally investigate and characterize the various
emission control alternatives outlined.
Because of the scope of the program needed to fulfill the require-
ments of S. B. 393, the results are presented in a seven volume report*
Volume VI is the data base generated in the testing program. The
quantity of data resulting from the evaluation of the various control
alternatives was such that volume VI was further divided into three
sub-volumes.
This report, volume VI A, contains the data generated by the
evaluation of an Idle inspection and maintenance program in the
private sector.
Other volumes of the report discuss the manner in which the vehicle
sample was selected, the procedures used in testing the vehicles and
collecting the data, and the test sequences followed by the various
-------
cars. This volume will be limited to the methods of data reduction
and the presentation of the reduced data.
-------
2. DATA REDUCTION
A detailed account of the data accumulation process is contained
in volume II of this report. To facilitate discussion of data treat-
ment after collection, the steps of the test sequence are listed in
Table 1.
1. Collect vehicle information (make, model, CID, etc.)
2. Initial exhaust emission test
3. Initial inspection of vehicle maintenance status
4. Idle inspection and maintenance at Inspection
station
5. Second exhaust emission test (if vehicle failed at
inspection station)
6. Second maintenance status (if vehicle failed
at inspection station)
TABLE 1. Data Collection Procedure
The vehicle information collected at step 1. required no data
reduction.
2.1 EMISSION TESTS
The emission tests actually consisted of three separate tests,
the 1975 Federal mass emission test, a key mode (Clayton Mfg. Co.)
test, and an idle test.
2.1.1 Federal Test Procedure
These tests were performed according to procedures stipulated
in the Federal Register, Volume 38, Number 124, Part III dated June 28,
1973. The data is accumulated through the constant volume sampler
technique in which diluted samples of the exhaust are collected in a
bag. Simultaneously, samples of background air are also bagged. The
-------
test is divided into three parts with the exhaust sample from each
portion being collected in a separate bag. The first portion is
designated the cold transient phase and lasts for the first 505 seconds
of the driving schedule. The second is the cold stabilized phase
and consists of the remaining 867 seconds of the driving schedule. The
third portion is the hot transient phase and is a repeat of the cold
transient phase. The data thus collected is then reduced to mass
emissions using the equations shown in Appendix 1. The mass emissions
of the exhaust can then be used to calculate fuel consumption with
the equation developed in Appendix 2.
2.1.2 Key Mode Test Procedure
Immediately following each mass emission test, a key mode test
was performed using procedures outlined by Clayton Manufacturing
Company of El Monte, California. The key mode test consists of
measuring exhaust concentrations during idle, a loaded low cruise
steady state mode, and a loaded high cruise steady state mode. The
concentration of each emittant is corrected as specified in CALIFORNIA
EXHAUST EMISSION STANDARDS AND TEST PROCEDURES FOR 1972-MODEL GASOLINE-
POWERED MOTOR VEHICLES UNDER 6001 POUNDS GROSS VEHICLE WEIGHT, as
amended on February 17, 1971, which specifies that exhaust gas concen-
trations shall be adjusted to a dry exhaust volume containing 14.5
mole percent carbon atoms by applying the following dilution factor.
14.5/(% C02 + (0.5)% CO + (1.8 X 6)7, HC)
This correction factor was not applied to the readings taken with
garage type instruments.
2.1.3 Idle Test Procedure
The idle test procedure is the procedure by which the inspection
stations performed the initial vehicle inspection. This is specified
-------
Co be an exhaust concentration measurement of hydrocarbons and carbon
monoxide at curb idle and at 2500 engine RPM (transmission in neutral).
These measurements were taken with the garage type instrument. The
curb idle portion of this test was taken simultaneous with the idle
portion of the key mode.
2.2 VEHICLE MAINTENANCE STATUS INSPECTION
Upon completion of the emission tests, the vehicle was moved to
a staging area where the condition of various engine components and
adjustments were ascertained by specified procedures as shown in
Appendix 3. The results required no data reduction and were used as
reported.
2.3 IDLE INSPECTION AND MAINTENANCE
The idle Inspection was performed at one of the ten inspection
stations. Inspections were performed in accordance with the Idle
Test Procedures for Participating Garages following guidelines presented
at inspector and mechanic training sessions. Again, this data required
no reduction and was used as reported.
-------
3. INSPECTION AND MAINTENANCE EVALUATION DATA
The data presented on the following pages is divided into several
sections which depend on the type of test performed or the type of infor-
mation collected.
3.1 HEADING
The heading contains a physical description of the vehicle and
indicates which tests were conducted using the vehicle.
The first line identifies the vehicle by an assigned number.
The second line identifies the following items:
1. Vehicle model year
2. Vehicle make
3. Vehicle model
4. Engine displacement in cubic Inches
5. The inertia weight used during vehicle testing
6. The tests performed using the vehicle. IDLE
INSPECTION ONLY indicates the vehicle was used only
for evaluation of the idle inspection and resulting
maintenance. SEA LEVEL RETROFIT Indicates that
in addition to Idle inspection the vehicle was
also utilized In the sea level retrofit evaluation.
HIGH ALTITUDE RETROFIT indicates a high altitude
retrofit test in addition to the idle inspection.
TUNE UP EVALUATION indicates that in addition to
the idle Inspection the vehicle was also used In
the moillfied tuning specifications program.
COMBINATION RETROFIT indicates that after the
idle inspection evaluation the vehicle was used
to evaluate both sea level and altitude retrofits.
The third line identifies these items:
1. Number of cylinders
2. Number of carburetor Venturis
3. Transmission type
4. Number of miles the vehicle has been driven
5. Whether or not the vehicle has an emission control
system, an evaporative control system, or a PCV
valve.
3.2 MAINTENANCE STATUS
The data reported in this section reveals Information concerning
the state of various engine components and adjustments. The first
-------
line reports the status as the vehicle was received from the owner
while the second line gives the same information for the vehicle after
the idle inspection and maintenance procedure. The data are represented
in the following order.
I. CO - This is a measurement of tailpipe carbon monoxide
concentration in mole percent, measured with a lab
type infra red instrument.
I. RPM - Idle RPM, this is reported as a deviation from the
manufacturer's specified setting. A positive value
indicates an actual RPM higher than specified.
TIM - Ignition timing, reported in degrees, as a deviation
from the manufacturer's specified setting. A positive
value indicates an advance in timing from specifications.
DWL - Dwell, reported in degrees, as a deviation from the
setting specified by the manufacturer. A positive
value indicates a setting greater than specified.
PCV - Indicates whether the PCV valve is functioning properly.
NA indicates not applicable.
A. CL - Indicates whether the air cleaner element is acceptable
or not.
CHOKE - Indicates if the choke is functioning properly.
A. PMP - Indicates whether or not the air pump is operating
properly.
MISF. - Indicates ignition misfire.
NOXC. - Indicates whether or not the NOx control is functioning
properly.
3.3 IDLE INSPECTION
This section presents the data exactly as reported by the various
inspection stations. The first item identifies the station which
performed the inspection. The following lines are the data for each of
the individual steps followed during garage inspection and subsequent
maintenance. The last line is the total of all charges incurred.
-------
The first column identifies the individual steps of the test
data is presented as follows.
- Hydrocarbon concentration in the exhaust, measured at
curb idle, in P.P.M. hexane.
- Exhaust hydrocarbon concentration measured at an unloaded
2500 RPM engine speed, In P.P.M. hexane.
- Carbon monoxide concentration in the exhaust,
measured at curb idle, in mole percent.
- Exhaust carbon monoxide concentration measured at an
unloaded 2500 RPM engine speed, in mole percent.
- Indicates the reason the vehicle failed, A failure
because of hydrocarbon and carbon monoxide is signified
by BOTH.
- This is the cost for that particular step of the Inspec-
tion. Note that the charge listed as REPAIRS is for
parts and labor while the other costs are for only
inspections and adjustments. The cost listed after
FINAL INSPECTION is an estimated cost to bring a vehicle
continuing to fail the inspection.into compliance.
* - The hydrocarbon instrument has a full scale reading of 2000
P.P.M. and the carbon monoxide full scale value is 10%. Off
scale values are printed as asterisks (*****).
3.4 AS RECEIVED FROM OWNER
The Initial emission tests were performed on the vehicle In the
condition in which it was delivered to the laboratory. The data from
these tests are presented In this section. The first items are the
test number, the date the test was conducted, and the ambient conditions
at the time the test was performed. The ambient conditions are:
BAR: barometric pressure in Inches of mercury.
DB: dry bulb temperature In degrees Fahrenheit.
WB: wet bulb temperature in degrees Fahrenheit.
REL. HUM: relative humidity in percent.
NOX COR: humidity correction factor applied to the oxides of
nitrogen mass emissions.
The remaining
I. HC*
2500 HC*
I. CO*
2500 CO*
FAILURE
COST
-------
3.4.1 Federal Test Procedure
The first four lines of data are the results of the Federal Test
Procedure. These results are reported as follows:
HC - Unburned hydrocarbons emitted during the test phase in
grams per mile.
CO - Carbon monoxide emitted during the test phase in grams per
mile.
CO2 - Carbon dioxide emitted during the test phase in grams per
mile.
NOx - Oxides of nitrogen emitted during the test phase In grams
per mile nitrogen dioxide.
MPG - Fuel consumption in miles per gallon for the test phase.
3.4.2 Key Mode Test Procedure
The next three lines are data obtained during the key mode test.
These results are presented as follows:
3C - Concentration of unburned hydrocarbons in exhaust, reported
in P.P.M. carbon.
CO - Concentration of carbon monoxide in exhaust, in mole percent.
N0X - Oxides of nitrogen in exhaust in P.P.M.
LHC* - Concentration of unburned hydrocarbons in exhaust, in P.P.M.
hexane.
SHC* - Concentration of unburned hydrocarbons in exhaust, in
P.P.M. hexane as measured with the garage type instrument.
SCO* - Concentration of carbon monoxide in exhaust, reported in
mole percent as measured with garage type instrument.
* - LHC has a full scale value of 1600 P.P.M., SHC has a full
scale value of 2000 P.P.M. and SCO has a full scale value of
10%. Off scale readings are reported as asterisks (****).
3.4.3 Idle Test Procedure
Following the keymode test, the unburned hydrocarbons and carbon
monoxide concentrations in the exhaust were measured with the engine
operating at 2500 RPM and the transmission in neutral. The readings
-------
were taken with the garage type equipment and are reported on the last
line as described in section 3.4,2.
3.5 AS RECEIVED FROM INSPECTION
After the vehicle underwent the idle inspection at the station,
it was returned to the laboratory where a second emission test was
performed to evaluate the effectiveness of the Inspection and mainte-
nance procedure. These tests followed the format of testing conducted
when the vehicle was first received. Data are presented as described In
section 3.4.
-------
4. LISTING OF DATA
-------
*** COLORADO-393 ***
VEHICLE 001
1965 OLDS DELT 425 4500LBS
8CYL 4BBL AUTOMATIC 040150 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
saaaaaaaaaaaaaaaaaaa:
aasstasaa
»= MAINTENANCE STATUS
I. CO
I. RPM
TIM DWL
PCV
A.CL 1
FROM OWNER 5.59
+0125
-05 —01
BAD
OK
FROM INSP. 5.59
+0125
-05 -01
BAD
OK
IDLE INSPECTION
STATION NO. 9
I.HC
2500HC
I. CO
2500CO
INITIAL INSPECTION
320
150
4.20
4.80
AFTER I. RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
320
150
4.20
4.80
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
FAILURE COST
PASS 4.00
PASS
4.00 TOT.
***************************
TEST NO:C0001
AS RECEIVED FROM OWNER ***************************
08/07/73 BAR:24.65 DB:76 WB:60
REL.HUM:41.5% NOX COR: .965
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
19.26
6.28
5.60
8.81
247.5
118.6
106.6
142.3
483.2
513.5
477.5
497.2
1.66
1.50
2.01
1.68
9.54
12.37
13.44
11.90
5022
3438
3366
5.87
3.01
3.52
47
802
1240
439
293
264
385
246
220
140
6.25
3.30
3.50
4.70
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0001
08/07/73 BAR:24.65 DB:76 WB:60
REL.HUM:41.5% NOX COR: .965
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
19.26
6.28
5.60
8.81
247.5
118.6
106.6
142.3
483.2
513.5
477.5
497.2
1.66
1.50
2.01
1.68
9.54
12.37
13.44
11.90
5022
3438
3366
5.87
3.01
3.52
47
802
1240
439
293
264
385
246
220
140
6.25
3.30
3.50
4.70
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 002
1967 MERC COUG 289 3500LBS
8CYL 4BBL AUTOMATIC 070863 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
=== MAINTENANCE STATUS
I. CO
I.RPM
TIM DWL PCV A,
.CL
CHOKE
A.PMP
MISF
FROM
OWNER
7.50
-0075
-10 +03 OK
OK
OK
NA
NO
FROM
INSP.
3.60
-0125
-06 +02 OK
OK
OK
NA
NO
NOXC
NA
NA
IDLE INSPECTION
STATION NO. 7
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
500
400
400
2500HC
520
460
520
I. CO
7.40
3.10
3.10
2500CO
5.90
6.80
3.10
FAILURE
CO
PASS
PASS
COST
2.50
5.00
30.00
37.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0003
HC CO CO2
COLD TRANSIENT 17.95 178.6 402.2
COLD STABILIZED 10.42 168.1 425.3
HOT TRANSIENT 10.21 187.0 352.9
1975 COMPOSITE 11.94 175.6 400.4
08/07/73 BAR:24.65 DB:74 WB:57
REL.HUM:37.1% NOX COR: .918
NOX
1.78
1.65
1.08
1.52
MPG
12.04
12.33
13.11
12.48
LHC
SHC
SCO
IDLE KEYMODE
7647
8.03
90
726
600
7.60
LOW CR. KEYMODE
6680
6.93
549
888
810
6.80
HI. CR. KEYMODE
6773
9.93
202
856
765
9.60
2500 RPM
580
6.80
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0015
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
08/10/73 BAR:24.75 DB:75 WB:55
REL.HUM:28.9% NOX COR: .876
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
17.65
9.92
8.92
11.26
96.4
88.7
95.0
92.0
472.3
425.2
380.2
422.6
4.42
2.63
3.02
3.11
13.10
14.94
15.97
14.78
10592
5434
5070
4.26
1.99
2.01
103
2161
2560
1195
716
598
910
590
500
350
4.00
2.05
2.10
3.30
AUTOMOTIVE TESTING LABORATORIES.INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 003
1966 BUIC LESA 340 4000LBS
8CYL 4BBL AUTOMATIC 022750 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
MAINTENANCE STATUS
I. CO I.RPM TIM DWL PCV A.CL
FROM OWNER 2.90 +0130 +13 -01 OK OK
FROM INSP. 5.00 +0130 +00 -02 OK OK
CHOKE A.PMP MISF. NOXC
OK NA YES NA
OK NA NO NA
STATION NO. 8
IDLE INSPECTION
I.HC
2500HC
I.
• CO
2500CO
FAILURE
COST
INITIAL INSPECTION
1000
400
1.
.60
5.00
BOTH
3.50
AFTER I.RPM ADJUST
1550
550
1.
.35
3.60
HC
1.50
AFTER I.MX/TM ADJ1
1200
1000
0.
.00
7.60
BOTH
2.50
AFTER I.MX/TM ADJ2
0
0
0,
.00
0.00
NO ANS.
1.50
REPAIRS
10.75
FINAL INSPECTION
795
300
5.
.60
5.20
PASS
19.75 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0002
08/07/73 BAR:24.64 DB:72 WB:58
REL.HUM:45.3% NOX COR: .951
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.50
6.78
6.27
6.79
188.7
144.1
156.0
156.8
408.2
416.3
367.1
401.0
1.62
1.37
1.47
1.45
12.23
13.41
14.09
13.32
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
7776
4349
4502
3.18
7.07
11.08
76
457
235
1185
504
484
800
430
405
1650
3.10
6.90
5.40
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0007
08/08/73 BAR:24.77
REL.HUM:38.4%
DB: 76
NOX COR
WB: 59
: .942
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
9.25
6.78
5.95
7.06
198.8
164.1
161.8
170.7
402.1
405.6
359.7
392.1
0.87
0.62
0.87
0.74
11.97
13.00
14.07
13.05
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4730
3563
4047
5.11
6.97
10.67
44
233
155
458
388
415
420
335
350
325
5.00
7.10
*****
6.20
AUTOMOTIVE
TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 004
1967 BUIC SPEC 300 3500LBS
8CYL 2BBL AUTOMATIC 048935 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
MAINTENANCE STATUS
I.CO I.RPM TIM DWL PCV A.CL
FROM OWNER 6.30 -0040 +12 +02 OK OK
FROM INSP. 5.30 +0075 +00 +01 OK OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 6
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
600
310
400
400
2500HC
90
160
130
130
I. CO
8.00
7.50
5.60
5.60
2500CO
3.05
4.40
3.60
3.60
FAILURE
CO
CO
PASS
PASS
COST
4.50
1.80
1.80
8.10 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0005
08/08/73 BAR:24.75 DB:73 WB:60
REL.HUM:49.2% NOX COR: .986
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
19.97
8.35
6.84
10.36
239.8
163.2
153.5
176.5
405.3
393.4
357.7
386.0
1.10
0.56
1.13
0.83
10.53
13.17
14.35
12.80
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
5303
3799
5055
6.58
4.59
10.90
35
481
131
484
398
533
455
365
460
280
6.90
4.60
*****
4.30
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:COO13
08/09/73 BAR:24.79 DB:80 WB:56
REL.HUM:22.5% NOX COR: .862
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
18.61
5.90
5.93
8.57
230.2
145.4
131.2
159.2
385.9
388.8
344.4
375.9
0.92
0.47
1.03
0.72
11.04
14.01
15.64
13.64
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4514
3878
5040
5.27
5.28
10.79
42
457
133
476
404
535
390
355
440
245
5.30
4.70
*****
3.50
AUTOMOTIVE TESTING LABORATORIES.INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 006
1967 CADI SEDA 429 5000LBS
8CYL 4BBL AUTOMATIC 104304 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
*== MAINTENANCE STATUS =====
I. CO
I. RPM
TIM DWL
PCV
A.CL
CHOKE
A.PMP
MISF.
NOXC
FROM OWNER 9.10
+0040
+05 +00
OK
OK
OK
NA
NO
NA
FROM INSP. 6.70
+0050
+02 +00
OK
OK
OK
NA
NO
NA
Till F TN^PFPTTnN
iujju inorCiui iUii
STATION NO. 10
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
530
420
8.40
5.40
CO
1.50
AFTER I.RPM ADJUST
620
380
8.00
4.80
BOTH
0.00
AFTER I.MX/TM ADJ1
500
180
5.00
3.80
PASS
3.00
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
500
180
5.00
3.80
PASS
4.50 TOT.
£ sb k k k k k k k A * k k k k k k k k k k A k k k
TEST NO:C0006
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
AS RECEIVED FROM OWNER ***************************
08/08/73 BAR:24.75 DB:80 WB:60
REL.HUM:32.8% NOX COR: .935
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
13.07
11.74
9.14
11.30
237.8
243.0
180.5
224.6
605.7
505.5
483.3
520.3
2.02
1.01
2.04
1.51
8.72
9.63
11.19
9.80
9593
4336
3515
9.83
4.79
4.52
25
607
783
674
502
305
600
445
245
370
9.70
4.80
4.10
6.00
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0012
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
08/09/73 BAR:24.79 DB:75 WB:56
REL.HUM:31.7% NOX COR: .892
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
11.68
9.78
7.92
9.66
235.7
232.9
169.7
216.0
569.6
476.5
463.6
492.4
1.70
0.83
1.87
1.30
9.12
10.20
11.79
10.33
5714
4372
3476
7.00
4.78
3.48
35
621
1034
573
502
296
470
420
240
365
7.00
4.65
3.40
6.20
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 007
1966 CHEV IMPA 327 4000LBS
8CYL 4BBL AUTOMATIC 043884 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
== MAINTENANCE
; STATUS
= ====;
I. CO
I.RPM
TIM DWL
PCV A
.CL <
FROM OWNER 1.40
-0050
-32 -05
BAD
OK
FROM INSP. 3.30
+0120
-01 +01
BAD
OK
TnT F TN
-------
*** COLORADO-393 ***
VEHICLE 008
1964 VOLK SEDA 73 2000LBS
4CYL 1BBL 4 SPEED 105861 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, NO PCV
FROM OWNER
FROM INSP.
I.CO
4.40
4.40
I.RPM
+0330
+0330
MAINTENANCE STATUS
TIM
-22
-22
DWL
-15
-15
PCV
NA
NA
A.CL
BAD
BAD
CHOKE
OK
OK
A.PMP
NA
NA
MISF.
NO
NO
NOXC
NA
NA
STATION NO. 4
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC
400
2500HC
600
400 600
I. CO
2.50
2500CO
4.70
2.50 4.70
FAILURE COST
PASS 5.00
PASS
5-00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0009
08/09/73 BAR:24.80 DB:75 WB:58
REL.HUM:37.7% NOX COR: .928
SCO
HC
CO
CO 2
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.73
8.27
5.43
7.16
70.3
75.7
61.0
70.5
207.7
213.9
195.2
207.4
1.83
1.29
1.69
1.51
26.23
24.80
28.89
26.13
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
6165
4917
4530
4.73
4.48
5.68
59
1293
1540
533
563
406
405
420
300
2500 RPM
355
4.65
4.30
5.50
6.90
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0009
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
08/09/73 BAR:24.80 DB:75 WB:58
REL.HUM:37.7% NOX COR: .928
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
6.73
8.27
5.43
7.16
70.3
75.7
61.0
70.5
207.7
213.9
195.2
207.4
1.83
1.29
1.69
1.51
26.23
24.80
28.89
26.13
6165
4917
4530
4.73
4.48
5.68
59
1293
1540
533
563
406
405
420
300
355
4.65
4.30
5.50
6.90
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 010
1966 CHRY 300 383 4000LBS
8CYL 4BBL AUTOMATIC 066648 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
AINTENANCE
STATUS ====
I. CO
I. RPM
TIM
DWL
PCV A.CL
CHOKE
A.PMP
MISF
FROM
OWNER
8.52
+0190
+07
-05
OK BAD
OK
NA
NO
FROM
INSP.
6.07
+0080
+00
+03
OK BAD
OK
NA
NO
IDLE INSPECTION
NOXC
NA
NA
STATION NO.
INITIAL INSPECTION
RPM ADJUST
MX/TM ADJ1
MX/TM ADJ2
AFTER I
AFTER I
AFTER I
REPAIRS
FINAL INSPECTION
I.HC
325
320
220
220
2500HC
175
200
400
400
I. CO
6.90
6.90
2.60
2.60
2500CO
5.00
5.50
1.75
1.75
FAILURE
CO
CO
PASS
PASS
COST
0.00
0.00
12.00
12.00 TOT.
¦k'k&&'k'kic'k&A A ** A A A A "k A
TEST NO:C0008
AS RECEIVED FROM OWNER ***************************
08/08/73 BAR:24.75 DB:83 WB:58
REL.HUM:22.6% NOX COR: .878
HC CO
COLD TRANSIENT 12.14 242.4
COLD STABILIZED 9.79 179.4
HOT TRANSIENT 8.51 161.3
1975 COMPOSITE 9.93 187.6
IDLE KEYMODE 8313 9.01
LOW CR. KEYMODE 5223 5.73
HI. CR. KEYMODE 5240 7.49
2500 RPM
C02
NOX
MPG
LHC
SHC
475.4
1.76
9.95
452.5
1.49
11.63
435.1
2.44
12.45
452.5
1.81
11.44
28
734
820
908
559
590
734
500
510
SCO
350
9.80
5.80
7.70
6.40
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0016
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
08/10/73 BAR:24.7 4 DB:78 WB:56
REL.HUM:25.9% NOX COR: .875
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
28.01
8.54
7.22
12.25
304.1
147.5
134.1
176.6
401.5
462.9
432.8
441.7
0.93
1.60
2.27
1.65
9.20
12.34
13.36
11.75
5468
5298
5294
6.39
6.10
7.38
60
793
782
603
580
530
620
510
430
280
7.00
6.10
7.40
6.10
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE Oil
1966 CHEV CHE2 194 3000LBS
6CYL 1BBL 3 SPEED 072251 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
MAINTENANCE STATUS
I.CO I.RPM TIM DWL PCV A.CL
FROM OWNER 9.50 -0065 -03 -02 OK BAD
FROM INSP. 8.00 -0115 -03 +01 OK OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 5
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
400
400
450
450
2500HC
250
300
300
300
I.CO
8.00
6.90
4.20
4.70
2500C0
4.80
4.80
4.80
4.80
FAILURE
CO
CO
PASS
PASS
COST
5.50
0.00
5.50
11.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0011
08/09/73 BAR:24.79 DB:84 WB:61
REL.HUM:28.0% NOX COR: .928
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
12.58
10.41
9.66
10.66
118.1
117.2
99.1
112.4
323.1
336.6
251.0
310.0
2.58
2.20
2.12
2.26
16.23
16.08
20.36
17.12
15629
3974
5675
10.16
1.62
9.82
24
2073
200
815
447
645
720
335
475
385
9.60
1.85
9.50
6.80
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0026
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
08/13/73 BAR:24.93 DB:78 WB:58
REL.HUM:31.2% NOX COR: .907
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
14.89
11.06
9.14
11.33
111.6
134.1
92.3
117.8
280.1
256.4
245.1
258.2
2.03
0.88
2.00
1.44
17.72
17.73
21.25
18.59
15775
4606
5642
8.98
2.59
8.17
25
1982
342
894
488
610
730
365
450
385
8.70
2.60
8.20
5.90
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 012
1967 CHRY STAU 383 5000LBS
8CYL 4BBL AUTOMATIC 063004 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
MAINTENANCE STATUS ==============================
I.CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 3.85 +0140 +00 +04 OK OK OK NA NO NA
FROM INSP. 3.85 +0140 +00 +04 OK OK OK NA NO NA
IDLE INSPECTION
STATION NO. 1
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
200
200
2500HC
90
90
I. CO
3.50
3.50
2500CO
2.70
2.70
FAILURE
PASS
PASS
COST
2.50
0.50
3.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0017
08/10/73 BAR:24.7 5 DB:78 WB:55
REL.HUM:23.3% NOX COR: .858
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
17.12
5.27
4.84
7.63
233.0
91.8
78.7
117.7
499.4
562.4
511.7
535.1
1.90
2.04
2.97
2.27
9.68
12.31
13.69
11.97
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
4076
3862
3679
4.25
3.50
3.86
92
1032
1465
484
330
273
380
360
230
2500 RPM
140
4.10
3.50
4.10
3.30
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:COO 17
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
08/10/73 BAR:24.75 DB:78 WB:55
REL.HUM:23.3% NOX COR: .858
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
17.12
5.27
4.84
7.63
233.0
91.8
78.7
117.7
499.4
562.4
511.7
535.1
1.90
2.04
2.97
2.27
9.68
12.31
13.69
11.97
4076
3862
3679
4.25
3.50
3.86
92
1032
1465
484
330
273
380
360
230
140
4.10
3.50
4.10
3.30
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 013
1965 DODG DART 225 3000LBS
6CYL 1BBL AUTOMATIC 032679 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
FROM OWNER
FROM INSP.
I. CO
3.20
3.20
MAINTENANCE STATUS
I.RPM
-0010
-0010
TIM
+07
+07
DWL
+01
+01
PCV
OK
OK
A.CL
OK
OK
CHOKE
BAD
BAD
A.PMP
NA
NA
MISF.
NO
NO
NOXC
NA
NA
STATION NO.
8
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC
210
2500HC
170
210 170
I. CO
1.50
2500CO
1.30
1.50 1.30
FAILURE COST
PASS 3.50
PASS
3.50 TOT.
RECEIVED FROM OWNER **&***£****££**************
TEST NO:COOl4
08/10/73 BAR:24.75 DB:70 WB:56
REL.HUM:43.8% NOX COR: .925
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
HC
9.17
3.43
2.93
4.49
CO
149.8
47.4
50.0
69.5
C02
347.9
361.9
338.9
352.6
NOX
3.59
4.75
5.44
4.70
MPG
14.54
19.91
20.87
18.71
LHC
SHC
SCO
IDLE KEYMODE
4086
3.29
278
468
405
3,
,35
LOW CR. KEYMODE
2861
0.92
3377
264
205
1.
.00
HI. CR. KEYMODE
2741
1.49
3464
229
190
1.
.60
2500 RPM
185
1,
.75
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0014
08/10/73 BAR:24.7 5 DB:70 WB:56
REL.HUM:43.8% NOX COR: .925
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
9.17
3.43
2.93
4.49
149.8
47.4
50.0
69.5
347.9
361.9
338.9
352.6
3.59
4.75
5.44
4.70
14.54
19.91
20.87
18.71
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4086
2861
2741
3.29
0.92
1.49
278
3377
3464
468
264
229
405
205
190
185
3.35
1.00
1.60
1.75
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 014
1964 CHEV CHE2 194 3000LBS
6CYL 1BBL 3 SPEED 049237 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
MAINTENANCE STATUS
I.CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 0.09 -0100 -12 +02 OK OK OK NA NO NA
FROM INSP. 0.09 -0100 -12 +02 OK OK OK NA NO NA
IDLE INSPECTION
STATION NO. 9
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
320
320
2500HC
260
260
I.CO
0.20
0.20
2500C0
1.40
1.40
FAILURE
PASS
PASS
COST
4.00
4.00 TOT.
*************************** as RECEIVED FROM OWNER ***************************
TEST NO:COO18
08/10/73 BAR:24.75 DB:78 WB:56
REL.HUM:25.9% NOX COR: .874
SCO
HC
CO
CO 2
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
13.48
9.31
7.02
9.55
109.0
107.9
75.0
99.0
280.5
263.1
247.6
262.5
1.80
0.99
1.73
1.37
18.01
19.27
22.97
19.87
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
6665
4288
5044
0.14
2.83
10.20
43
2071
176
958
431
502
640
365
415
2500 RPM
365
0.15
2.90
9.80
4.30
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:COO 18
08/10/73 BAR:24.75 DB:78 WB:56
REL.HUM:25.9% NOX COR: .874
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
13.48
9.31
7.02
9.55
109.0
107.9
75.0
99.0
280.5
263.1
247.6
262.5
1.80
0.99
1.73
1.37
18.01
19.27
22.97
19.87
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
6665
4288
5044
0.14
2.83
10.20
43
2071
176
958
431
502
640
365
415
365
0.15
2.90
9.80
4.30
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 015
1967 FORD STAU 289 3500LBS
8CYL 2BBL 3 SPEED 060240 MILES
SEA LEVEL RETROFIT
HAS: NO EMC, NO EVC, PCV
============================== MAINTENANCE STATUS
I.CO I.RPM TIM DWL PCV A.CL
FROM OWNER 8.60 -0075 +00 +00 OK OK
FROM INSP. 6.20 -0095 +00 +01 OK OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA YES NA
STATION NO. 4
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC
390
355
450
450
2500HC
200
200
190
190
I. CO
7.50
8.80
4.50
4.50
2500CO
4.80
5.00
4.80
4.80
FAILURE
CO
CO
PASS
PASS
COST
5.00
1.00
1.00
7.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST N0:C0021
08/13/73 BAR:24.94 DB:77 WB:60
REL.HUM:39.0% NOX COR: .953
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
13.66
15.31
9.79
13.43
126.5
171.4
115.2
146.4
331.4
303.4
276.4
301.8
1.09
0.40
0-87
0.67
15.53
14.34
18.23 -
15.51
19106
5136
5100
8.87
4.35
4.95
14
687
604
848
589
613
720
460
485
345
9.40
4.50
4.90
5.90
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0027
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
08/14/73 BAR:24.80 DB:73 WB:55
REL.HUM:33.1% NOX COR: .887
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
11.78
10.42
9.30
10.39
125.1
134.7
106.3
124.8
382.2
376.5
316.3
361.0
1.03
0.59
1.00
0.80
14.46
14.34
17.36
15.10
8713
5531
4784
6.90
4.29
4.41
35
759
596
737
640
525
550
410
315
305
6.75
4.40
4.40
6.30
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 016
1967 FORD FALC 289 3000LBS
8CYL 2BBL AUTOMATIC 059003 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
MAINTENANCE STATUS ==============================
I.CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 6.10 +0045 +€0 +00 OK BAD OK NA NO NA
FROM INSP. 6.10 +0045 +00 +00 OK BAD OK NA NO NA
STATION NO. 5
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC
350
2500HC
250
350 250
I. CO
5.10
2500CO
5.00
5.10 5.00
FAILURE COST
PASS 5.50
PASS
5.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0022
08/13/73 BAR:24.94 DB:76 WB:59
REL.HUM:38.3% NOX COR: .939
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.47
7.38
6.23
7.08
96.9
134.8
106.0
118.9
398.8
362.8
332.0
361.8
2.50
1. 10
1.67
1.55
15.49
14.89
17. 18
15.60
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
5167
5372
5561
6.52
4.22
7.52
70
894
293
600
672
618
450
560
500
2500 RPM
365
6.50
4.20
7.80
6.40
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0022
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
08/13/73 BAR:24.94 DB:76 WB:59
REL.HUM:38.3% NOX COR: .939
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
7.47
7.38
6.23
7.08
96.9
134.8
106.0
118.9
398.8
362.8
332.0
361.8
2.50
1.10
1.67
1.55
15.49
14.89
17.18
15.60
5167
5372
5561
6.52
4.22
7.52
70
894
293
600
672
618
450
560
500
365
6.50
4.20
7.80
6.40
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 017
1966 CHEV BISC 283 4000LBS
8CYL 2BBL AUTOMATIC 051045 MILES
SEA LEVEL RETROFIT
HAS: NO EMC, NO EVC, PCV
FROM OWNER
FROM INSP.
I.CO I.RPM
6.30 +0190
6.30 +0190
MAINTENANCE STATUS
TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
-18 -01 OK BAD BAD NA NO NA
-18 -01 OK BAD BAD NA NO NA
STATION NO. 10
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC
750
2500HC
500
750 500
I. CO 2500CO
5.00 5.00
5.00 5.00
FAILURE COST
PASS 1.50
PASS
1.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0020 08/13/73 BAR:24.94 DB:75 WB:62
REL.HUM:50.3% NOX COR:1.014
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
16.09
9.43
8.02
10.43
211.5
169.6
148.8
172.6
385.7
370.5
339.2
365.0
2.18
1.21
1.67
1.54
11.58
13.35
14.88
13.31
6007
5153
4177
6.77
6.09
4.01
82
647
1723
746
610
425
590
440
295
420
6.70
5.80
4.10
5.90
TEST NO:C0020
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
08/13/73 BAR:24.94 DB:75 WB:62
REL.HUM:50.3% NOX COR:1.014
HC
CO
C02
NOX
MPG
LHC
SHC
. SCO
16.09
9.43
8.02
10.43
211.5
169.6
148.8
172.6
385.7
370.5
339.2
365.0
2.18
1.21
1.67
1.54
11.58
13.35
14.88
13.31
6007
5153
4177
6.77
6.09
4.01
82
647
1723
746
610
425
590
440
295
420
6.70
5.80
4.10
5.90
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 019
1965 AMMO CLAS 232 3000LBS
6CYL 1BBL 3 SPEED 062545 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
========================= MAINTENANCE STATUS
I.CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 6.07 +0070 -06 +01 OK OK OK NA NO NA
FROM INSP. 6.56 -0030 +00+01 OK OK OK NA NO NA
IDLE INSPECTION
STATION NO. 6
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
440
440
400
400
2500HC
340
220
220
220
I. CO
8.60
7.80
5.60
5.60
2500CO
7.80
5.60
4.40
4.40
FAILURE
CO
CO
PASS
PASS
COST
4.50
1.50
1.50
7.50 TOT.
& ¦&&&&&&A jckick •k'k'k'kick'k A
AS
RECEIVED
FROM OWNER
***************************
TEST NO:C0023
08/13/73 BAR:2 4.9 3
DB :78
WB: 58
REL. HUM: 31.2%
NOX COR:
: .907
HC
CO
CO 2
NOX
MPG LHC
SHC
SCO
COLD TRANSIENT
8.25
119.1
287.4
1.74
17.79
COLD STABILIZED
8.09
121.3
262.4
0.87
18.61
HOT TRANSIENT
5.33
97.9
263.2
1.61
20.52
1975 COMPOSITE
7.36
114.4
267.9
1.26
18.92
IDLE KEYMODE
11888
9.22
30
725
555
8.70
LOW CR. KEYMODE
4273
4.93
1025
409
330
4.80
HI. CR. KEYMODE
4998
10.04
201
498
385
9.80
2500 RPM
310
5.60
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0034
08/14/73 BAR:24.77 DB:78 WB:61
REL.HUM:39.8% NOX COR: .971
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.08
5.24
4.46
5.20
102.0
80.9
75.8
83.9
251.6
253.0
246.1
250.8
1.46
0.94
1.72
1.26
20.66
22.44
23.47
22.32
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
6952
4201
4837
6.90
3.99
8.18
41
1208
333
648
417
501
620
380
450
250
5.80
3.60
8.00
2.80
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 020
1967 OLDS DELT 425 4500LBS
8CYL 4BBL AUTOMATIC 089113 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
MAINTENANCE STATUS
I. CO I.RPM TIM DWL PCV A.CL
FROM OWNER 5.60 +0040 +00 +02 OK BAD
FROM INSP. 3.60 +€020 +00 +02 OK BAD
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 2
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
****
****
400
400
2500HC
¦kifk-k
A ***
300
300
I. CO
2.00
1.60
4.20
4.20
2500CO
1.50
1.00
2.00
2.00
FAILURE
HC
HC
PASS
PASS
COST
5.50
3.30
3.30
3.30
15.40 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0025
08/13/73 BAR:24.93 DB:79 WB:59
REL.HUM:31.9% NOX COR: .919
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
9.93
7.28
7.03
7.77
167.8
126.9
110.1
130.8
546.5
500.7
461.7
499.5
2.11
1.49
1.95
1.75
10.58
12.32
13.56
12.21
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
5888
4602
3936
6.16
3.96
3.70
55
639
953
650
443
309
415
300
210
2500 RPM
280
5.80
3.90
3.60
5.70
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0A33
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
08/14/73 BAR:24.78 DB:78 WB:59
REL.HUM:34.1% NOX COR: .928
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
8.20
6.50
5.53
6.58
123.2
122.9
99.7
116.6
512.4
507.3
446.5
491.5
2.47
1.52
2. 11
1.88
12.17
12.35
14.35
12.81
4177
3732
3522
3.90
2.70
3.59
90
968
1109
442
327
257
430
330
250
370
3.50
2.35
3.45
6.50
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 021
1967 PLYM BELV 273 3500LBS
8CYL 2BBL AUTOMATIC 070009 MILES
SEA LEVEL RETROFIT
HAS: NO EMC, NO EVC, PCV
«============= MAINTENANCE STATUS
I.CO I.RPM TIM DWL PCV A.CL CHOKE A.PHP MISF. NOXC
FROM OWNER 6.30 +0080 -01 +01 OK OK BAD NA NO NA
FROM INSP. 6.30 ' +0080 -01 +01 OK OK BAD NA NO NA
IDLE INSPECTION
STATION NO. 3
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
370
370
2500HC
250
250
I. CO
1.80
1.80
2500CO
3.00
3.00
FAILURE
PASS
PASS
COST
6.00
6.00 TOT.
£*&** A******* ** ***** *******
AS RECEIVED FROM
. OWNER
***************************
TEST NO:C0028
08/14/73 BAR
:24.80
DB: 71
WB: 55
REL.HUM:
00
r-.
CO
NOX COR
: .900
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
11.37
201.0
361.0
1.45
12.49
COLD STABILIZED
10.85
189.4
350.9
1.06
13.04
HOT TRANSIENT
7.35
104.4
354.8
2.92
16.43
1975 COMPOSITE
9.98
168.2
354.1
1.66
13.70
IDLE KEYMODE
5573
7.20
56
573
410
6.75
LOW CR. KEYMODE
4380
2.93
1633
491
345
3.00
HI. CR. KEYMODE
4489
5.48
852
442
305
5.20
2500 RPM
350
4.90
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0028
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
08/14/73 BAR:24.80 DB : 71 WB:55
REL.HUM:37.8% NOX COR: .900
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
11.37
10.85
7.35
9.98
201.0
189.4
104.4
168.2
361.0
350.9
354.8
354.1
1.45
1.06
2.92
1.66
12.49
13.04
16.43
13.70
5573
4380
4489
7.20
2.93
5.48
56
1633
852
573
491
442
410
345
305
350
6.75
3.00
5.20
4.90
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 022
1971 CHEV VEGA 140 2500LBS
4CYL 2BBL 4 SPEED 040186 MILES
IDLE INSPECTION ONLY
HAS: EMC, EVC, PCV
============================== MAINTENANCE STATUS
I.CO I.RPM TIM DWL
FROM OWNER 8.52 -0040 +00 +00
FROM INSP. 5.20 -0060 +00 +00
PCV A.CL CHOKE A.PMP MISF. NOXC
OK BAD OK NA NO OK
OK BAD OK NA NO OK
IDLE INSPECTION
STATION NO. 2
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
230
230
160
160
2500HC
90
90
65
65
I. CO
6.90
6.80
3.10
3.10
2500CO
4.00
3.50
2.75
2.75
FAILURE
CO
CO
PASS
PASS
COST
5.50
3.30
3.30
12.10 TOT.
k k k k k k k k k k k k k k k k k k k k k k "k & k k *
AS i
RECEIVED
FROM OWNER
kkkk&kkkkkkkkkkkkkkkkkkkkkk
TEST NO:C0033
08/14/73 BAR
: 24.73
DB: 80
WB:61
REL.HUM:
35.52
NOX COR:
.957
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
7.85
83.0
293.6
1.96
19.84
COLD STABILIZED
8.12
88.0
330.8
1.32
18.00
HOT TRANSIENT
6.03
81.5
264.4
1.91
21.64
1975 COMPOSITE
7.49
85.1
304.6
1.62
19.28
IDLE KEYMODE
6785
9.20
57
579
580
9.50
LOW CR. KEYMODE
4023
3.39
475
255
200
3.50
HI. CR. KEYMODE
4057
3.95
1446
318
280
4.00
2500 RPM
-
750
3.40
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0043
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
08/15/73 BAR:24.82 DB:71 WB:56
REL.HUM:41.1% NOX COR: .917
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
8.25
4.49
4.61
5.31
80.4
66.6
66.1
69.3
292.4
320.2
259.3
297.5
1.84
1.48
1.91
1.67
20.01
20.28
23.58
21.05
4902
3889
4056
5.43
3.01
3.86
89
497
1424
380
220
309
610
300
440
300
5.20
3.10
4.00
3.10
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 023
1973 FORD STAW 400 5000LBS
8CYL 2BBL AUTOMATIC 003001 MILES
IDLE INSPECTION ONLY
HAS: EMC, EVC, PCV
FROM OWNER
FROM INSP.
=====
=========== MAINTENANCE STATUS
I. CO
I.RPM TIM DWL PCV A,
.CL
CHOKE
A.PMP
MISF
2.80
-0145 +08 -02 BAD
OK
OK
NA
YES
1.02
-0005 +00 -01 BAD
OK
OK
NA
YES
NOXC
OK.
OK
IDLE INSPECTION
STATION NO. 8
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
450
300
300
2500HC
110
70
70
I.CO 2500CO
1.70 1.50
0.50 0.50
0.50
0.50
FAILURE
HC
PASS
PASS
COST
3.50
2.00
5.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0031
08/14/73 BAR:24.78 DB:76 WB:58
REL.HUM:35.5% NOX COR: .922
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
HC
5.01
3.72
3.68
3.98
CO
91.7
69.5
68.0
73.7
C02
645.2
635.8
564.3
618.0
NOX
6.53
3. 15
5.85
4.61
MPG
11.06
11.77
13.04
11.93
LHC
SHC
SCO
IDLE KEYMODE
3450
3.15
114
337
320
3.00
LOW CR. KEYMODE
2804
1.47
2867
248
230
1.60
HI. CR. KEYMODE
2530
1.49
3430
189
170
1.55
2500 RPM
400
1.80
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0041
08/15/73 BAR:24.78 DB:72 WB:56
REL.HUM:38.6% NOX COR: .911
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.50
3.50
3.30
3.65
87.5
65.9
64.3
70.0
678.3
685.1
602.5
660.8
6.71
3.03
5.60
4.51
10.73
11.14
12.47
11.39
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2854
2562
2377
1.01
1.32
1.39
265
3225
3767
274
229
188
400
320
340
jcjcJck
1.00
1.20
1.50
1.10
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 024
1964 CHRY NEWP 361 4500LBS
8CYL 2BBL AUTOMATIC 099340 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
MAINTENANCE STATUS
I. CO I.RPM TIM DWL PCV A.CL
FROM OWNER 6.90 +0220 +00 +03 OK BAD
FROM INSP. 1.08 +0190 +00 +03 OK BAD
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO.
I.HC
2500HC
I.CO
2500CO
FAILURE
COST
INITIAL INSPECTION
380
490
8.00
8.80
CO
0.00
AFTER I.RPM ADJUST
380
150
8.00
8.50
CO
0.00
AFTER I.MX/TM ADJ1
140
150
1.50
9.00
CO
0.00
AFTER I.MX/TM ADJ2
160
180
1.20
8.50
CO
12.00
REPAIRS
30.57
FINAL INSPECTION
120
120
0.60
3.70
PASS
"k it "kick"kick je$ck'k'k'k&"kick Idc && &&&
TEST NO:C0024
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
42.57 TOT.
AS RECEIVED FROM OWNER ***************************
08/13/73 BAR:24.93 DB:78 WB:58
REL.HUM": 31.2% NOX COR: .907
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
11.18
6.81
6.43
7.62
271.2
210.1
203.7
221.1
443.0
^59.3
382.8
434.7
0.62
0.57
0.59
0.59
9.85
10.98
12.31
11.05
6111
5267
4944
7.39
9.52
9.12
66
130
192
765
552
466
520
385
300
220
7.30
9.10
8.80
9.30
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0042
08/15/73 BAR:24.78 DB:78 WB:58
REL.HUM:31.3% NOX COR: .909
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
/
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
9.25
4.57
4.70
5.59
223.7
86.5
123.6
125.5
433.5
491.5
403.3
454.9
0.92
1.27
1.13
1.16
10.94
13.88
14.54
13.30
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3208
4252
4305
1.20
6.53
6.99
163
348
544
343
442
410
600
740
710
320
1.20
6.50
7.10
5.20
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 025
1966 DODG VAN 273 3500LBS
8CYL 2BBL 3 SPEED 054740 MILES
SEA LEVEL RETROFIT
HAS: NO EMC, NO EVC, PCV
I. CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 7.70 +0030 +13 -03 OK OK OK NA NO NA
FROM INSP. 7.70 +0030 +13 -03 OK OK OK NA NO NA
IDLE INSPECTION
-STATION NO. 9
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
500
500
2500HC
240
240
I. CO
6.80
6.80
2500C0
7.00
7.00
FAILURE
PASS
PASS
COST
4.00
4.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0032
08/14/73 BAR:24.78 DB:79 WB:60
REL.HUM:34.8% NOX COR: .942
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
15.82
28.82
14.76
22.20
124.3
206.9
167.3
178.7
313.9
254.2
242.7
263.5
2.49
0.56
0.93
1.07
15.92
13.28
16.12
14.50
11411
6062
4845
8.96
8.45
5.65
40
367
1106
704
748
526
640
700
480
200
8.40
8.20
7.80
3.60
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0032
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
08/14/73 BAR:24.78 DB:79 WB:60
REL.HUM:34.8% NOX COR: .942
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
15.82
28.82
14.76
22.20
124.3
206.9
167.3
178.7
313.9
254.2
242.7
263.5
2.49
0.56
0.93
1.07
15.92
13.28
16.12
14.50
11411
6062
4845
8.96
8.45
5.65
40
367
1106
704
748
526
640
700
480
200
8.40
8.20
7.80
3.60
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 026
1965 CADI DEVI 429 5000LBS
8CYL 4BBL AUTOMATIC 084961 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
MAINTENANCE STATUS
I.CO I.RPM TIM DWL PCV A.CL
FROM OWNER 5.95 +0020 +00 +01 OK OK
FROM INSP. 5.95 +0020 +00 +01 OK OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 1
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I. MX/.TM AD J 2
REPAIRS
FINAL INSPECTION
I.HC
280
280
2500HC
80
80
I.CO 2500C0
4.00 1.00
4.00 1.00
FAILURE COST
PASS 2.50
PASS
2.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0029
08/14/73 BAR:24.80 DB:73 WB:56
REL.HUM:36.2% NOX COR: .904
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
7.39
99.8
578.1
4.50
11.74
COLD STABILIZED
5.88
83.8
539.5
4.60
12.91
HOT TRANSIENT
5.22
75.9
493.2
4.35
14.16
1975 COMPOSITE
6.01
85.0
534.8
4.51
12.96
IDLE KEYMODE
4859
6.36
73
518
370
6.10
LOW CR. KEYMODE
3516
0.83
2162
329
235
0.80
HI. CR. KEYMODE
3263
1.60
1995
251
165
1.70
2500 RPM
125
1.05
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0029
08/14/73 BAR:24.80 DB:73 WB:56
REL.HUM:36.2% NOX COR: .904
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.39
5.88
5.22
6.01
99.8
83.8
75.9
85.0
578.1
539.5
493.2
534.8
4.50
4.60
4.35
4.51
11.74
12.91
14.16
12.96
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4859
3516
3263
6.36
0.83
1.60
73
2162
1995
518
329
251
370
235
165
125
6.10
0.80
1.70
1.05
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 027
1965 MERC MONR 390 4000LBS
8CYL 2BBL AUTOMATIC 072548 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
============================== MAINTENANCE STATUS
I. CO I.RPM TIM DWL PCV A.CL CHOKE
FROM OWNER 1.01 -0025 +00 +02 BAD BAD BAD
FROM INSP. 1.01 -0025 +00 +02 BAD BAD BAD
A.PMP MISF. NOXC
NA YES NA
NA YES NA
IDLE INSPECTION —
STATION NO. 9
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
800
800
2500HC
350
350
I. CO
0.20
0.20
2500CO
0.40
0.40
FAILURE
PASS
PASS
COST
4.00
4.00 TOT.
*************************** Ag RECEIVED FROM OWNER ***************************
TEST NO:C0030
08/14/73 BAR:24.78 DB:76 WB:55
REL.HUM:26.9% NOX COR: .870
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
10.43
6.54
6.28
7.28
178.0
93.7
93.5
111.3
486.6
501.9
440.2
481.6
1.56
1.54
1.90
1.64
11.14
13.30
14.67
13.11
5150
4646
4065
1.17
4.51
2.74
144
849
1479
747
527
356
950
510
334
390
1.15
4.35
2.65
5.50
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* as RECEIVED FROM INSPECTION ' ************************
TEST NO:C0030
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
08/14/73 BAR:24.78 DB:76 WB:55
REL.HUM:26.9% NOX COR: .870
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
10.43
6.54
6.28
7.28
178.0
93.7
93.5
111.3
486.6
501.9
440.2
481.6
1.56
1.54
1.90
1.64
11.14
13.30
14.67
13.11
5150
4646
4065
1.17
4.51
2.74
144
849
1479
747
527
356
950
510
334
390
1.15
4.35
2.65
5.50
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 028
1964 OLDS STAW 330 4000LBS
8CYL 2BBL AUTOMATIC 089020 MILES
SEA LEVEL RETROFIT
HAS: NO EMC, NO EVC, NO PCV
FROM OWNER
FROM INSP.
I.CO
11.20
7.10
I.RPM
+0000
-0100
MAINTENANCE STATUS
TIM
+03
-07
DWL
-10
-16
PCV
NA
NA
A.CL
BAD
OK
CHOKE
BAD
OK
A.PMP
NA
NA
MISF.
NO
NO
NOXC
NA
NA
IDLE INSPECTION
STATION NO. 6
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
****
****
600
600
2500HC
1600
1600
500
500
I.CO
*****
*****
2.00
4.00
2500CO
9.40
8.00
2.80
2.80
FAILURE
BOTH
BOTH
PASS
PASS
COST
4.50
1.50
3.50
9.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0035
08/15/73 BAR:24.87 DB:68 WB:55
REL.HUM:45.9% NOX COR: .918
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
14.56
195.4
468.1
2.28
10.84
COLD STABILIZED
17.39
206.0
395.3
1.05
11.51
HOT TRANSIENT
12.17
199.6
402.8
1.66
11.80
1975 COMPOSITE
15.35
202.0
412.6
1.47
11.44
IDLE KEYMODE
38839
10.09
5
1373
1720
*****
LOW CR. KEYMODE
5481
7.18
356
613
535
7.40
HI. CR. KEYMODE
5504
9.08
305
541
500
9.80
2500 RPM
800
5.20
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0044
08/16/73 BAR:24.80 DB:70 WB:54
REL.HUM:37.0% NOX COR: .889
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
8.69
7.61
7.01
7.67
152.6
158.0
149.1-
154.4
448.6
408.8
389.3
411.7
1.52
0.72
1.13
1.00
12.44
13.07
13.79
13.13
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
6214
4354
5080
7.79
4.12
9.91
44
619
162
717
449
480
1050
580
600
375
7.80
4.00
9.80
4.10
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 029
1965 PONT TEMP 326 3500LBS
8CYL 2BBL AUTOMATIC 059585 MILES
SEA LEVEL RETROFIT
HAS: NO EMC, NO EVC, PCV
============================== MAINTENANCE STATUS ==============================
I.CO I.RPM TIM DWL PCV A.CL
FROM OWNER 7.30 -0010 -12 +02 OK OK
FROM INSP. 7.30 -0010 -12 +02 OK OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 4
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
250
2500HC
115
250 115
I.CO 2500CO
1.80 1.20
1.80 1.20
FAILURE
PASS
PASS
COST
5.00
5.00 TOT.
*************************** as RECEIVED FROM OWNER ***************************
TEST NO:C0036
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
08/15/73 BAR:24.87 DB:68 WB:54
REL.HUM:42.3% NOX COR: .901
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
15.56
10.61
8.81
11.15
234.1
193.7
163.8
193.9
396.4
366.8
328.7
362.4
0.71
0.52
0.72
0.61
10.95
12.63
14.50
12.68
8490
4474
5992
8.41
3.02
11.41
35
529
97
845
463
632
760
360
520
375
8.20
3.20
*****
5.15
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0036
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
08/15/73 BAR:24.87 DB:68 WB:54
REL.HUM:42.3% NOX COR: .901
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
15.56
10.61
8.81
11.15
234.1
193.7
163.8
193.9
396.4
366.8
328.7
362.4
0.71
0.52
0.72
0.61
10.95
12.63
14.50
12.68
8490
4474
5992
8.41
3.02
11.41
35
529
97
845
463
632
760
360
520
375
8.20
3.20
*****
5.15
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 030
1964 CADI DEVI 429 5000LBS
8CYL 4BBL AUTOMATIC 048156 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
==-=========================== MAINTENANCE STATUS
I. CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 5.60 +0015 +00 +00 BAD BAD OK NA NO NA
FROM INSP. 0.11 +0090 +00 +02 BAD BAD OK NA YES NA
STATION NO. 7
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
300
380
6.10
6.40
CO
2.50
AFTER I.RPM ADJUST
240
360
2.40
6.30
CO
2.50
AFTER I.MX/TM ADJ1
220
240
1.20
5.30
CO
2.50
AFTER I.MX/TM ADJ2
220
300
1.50
4.10
PASS
2.50
REPAIRS
FINAL INSPECTION
220
300
1.50
4.10
PASS
10.00 TOT.
** **************** *********
AS RECEIVED
FROM OWNER
*************** * * ** *** * ****
TEST NO:C0037
08/15/73 BAR
:24.87
DB :69
WB: 55
REL.HUM:
43.0%
NOX COR:
: .912
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
9.76
230.2
579.5
2.01
9.16
COLD STABILIZED
9.78
194.5
615.2
2. 10
9.36
HOT TRANSIENT
7.99
194.8
500.3
1.93
10.71
1975 COMPOSITE
9.28
202.0
575.8
2.03
9.65
IDLE KEYMODE
4645
5.96
72
436
390
5.95
LOW CR. KEYMODE
4520
6.08
639
409
343
6. 10
HI. CR. KEYMODE
4653
7.45
484
421
345
7.70
2500 RPM
390
5.90
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0056
08/16/73 BAR:24.67 DB:76 WB:58
REL.HUM:35.5% NOX COR: .923
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
8.88
8.82
8.16
8.65
203.4
149.6
183.2
170.2
572.5
610.6
493.0
570.0
1.93
2.05
1.83
1.96
9.68
10.19
11.04
10.30
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3910
4356
4724
0.14
6.20
8.93
69
596
316
414
425
467
500
710
660
700
0.17
6.50
9.00
6.20
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 031
1964 CHEV IMPA 327 3500LBS
8CYL 4BBL AUTOMATIC 060672 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
============================= MAINTENANCE STATUS ==============================
I. CO I.RPM TIM DWL PCV A.CL
FROM OWNER 6.10 +0030 +00 +01 NA BAD
FROM INSP. 2.60 -0025 +01 +02 NA OK
CHOKE A.PMP MISF. NOXC
BAD NA NO NA
OK NA NO NA
STATION NO. 1
IDLE INSPECTION
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
740
360
5.60
8.00
CO
2.50
AFTER I.RPM ADJUST
620
300
2.20
6.60
CO
5.35
AFTER I.MX/TM ADJ1
330
200
5.70
7.20
CO
0.00
AFTER I.MX/TM ADJ2
160
170
1.50
6.80
CO
0.00
REPAIRS
42.72
FINAL INSPECTION
700
900
4.00
9.00
BOTH
50.57 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0038
08/15/73 BAR:24.87 DB:71 WB:55
REL.HUM:37.8% NOX COR: .899
HC
CO
C02
NOX
MPG
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
8.85
8.81
6.72
8.24
143.5
171.3
126.0
152.9
418.8
367.6
361.2
376.5
2.00
0.75
1.64
1.26
13.25
13.40
15.34
13.86
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
5797
5178
4202
6.65
6.46
3.05
64
359
1461
LHC
SHC
SCO
657
670
6.45
588
550
6.60
419
360
3.40
405
6.20
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0073
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
08/18/73 BAR:24.7 6 DB:74 WB:62
REL.HUM:53.2% NOX COR:1.026
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
8.02
8.04
7.55
7.90
139.0
169.4
126.0
151.0
395.9
337.1
323.5
345.6
2.36
0.56
1.68
1.25
13.92
14.16
16.33
14.66
8504
6115
4185
3.90
8.55
1.86
48
178
2017
898
656
392
1050
940
500
780
3.00
8.50
2.00
8.50
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 033
1965 FORD MUST 200 3000LBS
6CYL 1BBL AUTOMATIC 065042 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
MAINTENANCE STATUS
I. CO I.RPM TIM DWL PCV A.CL
FROM OWNER 4.80 +0140 +00 -01 OK BAD
FROM INSP. 1.44 -0100 +00 -01 OK BAD
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
STATION NO. 10
— IDLE INSPECTION
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
880
410
4.20
4.80
tie
1.50
AFTER I.RPM ADJUST
880
410
4.20
4.80
HC
1.50
AFTER I.MX/TM ADJ1
860
500
3.80
5.00
HC
1.50
AFTER I.MX/TM ADJ2
780
520
2.20
5.20
PASS
1.50
REPAIRS
FINAL INSPECTION
780
520
2.20
5.20
PASS
6.00 TOT.
*************************** as RECEIVED FROM OWNER ***************************
TEST NO :.C0039
08/15/73 BAR:24.88 DB:73 WB:56
REL.HUM:36.1% NOX COR: .903
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
10.60
197.5
331.8
1.14
13.18
COLD STABILIZED
5.56
92.1
341.2
1.96
17.69
HOT TRANSIENT
5.72
129.3
301.3
1.28
17.04
1975 COMPOSITE
6.66
124.5
328.2
1.60
16.35
IDLE KEYMODE
5154
5.36
84
608
720
4.95
LOW CR. KEYMODE
4472
3.62
1251
494
505
3.65
HI. CR. KEYMODE
5339
10.78
185
516
500
*****
2500 RPM
360
6.40
A * A & A A A •& * "k je k k k k A k k k k k * k k k
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0057
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
08/16/73 BAR:24.7 6 DB:74 WB:58
REL.HUM:40.1% NOX COR: .936
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
14.59
4.91
4.78
6.90
201.3
87.5
112.1
118.2
354.4
354.2
287.8
335.8
1.26
1.98
1.42
1.67
12.42
17.56
18.59
16.40
4306
4278
4143
1.59
3.15
3.93
119
1423
1140
542
471
408
800
700
580
500
1.80
3.40
4.00
6.00
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 035
1965 DODG POLA 383 4000LBS
8CYL 2BBL AUTOMATIC 064463 MILES
SEA LEVEL RETROFIT
HAS: NO EMC, NO EVC, PCV
============================== MAINTENANCE STATUS ==============================
I. CO I.RPM TIM DWL PCV A.CL
FROM OWNER 4.30 +0240 +02 -03 OK OK
FROM INSP. 4.30 +0240 +02 -03 OK OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 3
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
240
240
2500HC
120
120
I.CO
3.00
3.00
2500CO
2.00
2.00
FAILURE
PASS
PASS
COST
6.00
6.00 TOT.
A*****************a******** AS RECEIVED FROM OWNER ***************************
TEST NO:C0046
08/16/73 BAR:24.78 DB:73 WB:55
REL.HUM:33.1% NOX COR: .888
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
10.54
6.88
6.32
7.49
195.4
132.7
133.0
145.9
453.6
494.0
432.7
468.5
1.85
2.08
2.09
2.03
11.21
12.29
13.46
12.35
4359
4574
4565
4.70
4.62
6.37
73
828
606
475
531
464
595
665
550
270
4.50
4.40
6. 10
2.30
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0046
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
08/16/73 BAR:24.78 DB:73 WB:55
REL.HUM:33.1% NOX COR: .888
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
10.54
6.88
6.32
7.49
195.4
132.7
133.0
145.9
453.6
494.0
432.7
468.5
1.85
2.08
2.09
2.03
11.21
12.29
13.46
12.35
4359
4574
4565
4.70
4.62
6.37
73
828
606
475
531
464
595
665
550
270
4.50
4.40
6.10
2.30
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 036
1965 BUIC SKYL 300 3500LBS
8CYL 2BBL AUTOMATIC 075400 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
============================== MAINTENANCE STATUS
I.CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 6.70 -0010 +07 -06 OK BAD BAD NA NO NA
FROM INSP. 5.07 +0040 +02 -06 OK BAD BAD NA NO NA
IDLE INSPECTION
STATION NO. 8
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
****
2000
600
2500HC
****
****
****
280
I. CO
2.60
2.20
1.50
1.00
2500CO
4.00
1.00
3.80
4.00
FAILURE
BOTH
BOTH
BOTH
PASS
COST
3.50
2.00
2.50
10.80
18.80 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0050
08/16/73 BAR:24.77 DB:77 WB:56
REL.HUM:27.8% NOX COR: .880
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
31.06
26.41
24.41
26.83
174.1
128.6
121.0
136.0
375.1
352.5
324.9
349.6
1.81
1.35
1.60
1.52
11.92
13.95
15.03
13.74
22115
18761
21871
7.51
4.66
7.54
35
641
369
1955
1866
1920
****
****
****
****
6.80
4.40
7.20
5.65
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0068
08/17/73 BAR:24.77 DB:73 WB:58
REL.HUM:42.6% NOX COR: .942
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.91
4.49
5.91
5.39
155.9
118.5
109.3
123.8
436.9
421.7
370.0
410.6
1.42
0.91
1.16
1.09
12.66
14.31
15.89
14.32
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3716
3528
3612
5.53
4.98
6.08
63
376
527
312
296
290
450
440
400
250
5.40
5.00
6.00
5.70
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 037
1964 FORD FAIR 289 3500LBS
8CYL 2BBL 3 SPEED 052629 MILES
SEA LEVEL RETROFIT
HAS: NO EMC, NO EVC, PCV
============================== MAINTENANCE STATUS =============================
I.CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 0.57 -0137 +06 +05 BAD BAD OK NA YES NA
FROM INSP. 6.60 +0000 +06 +05 BAD BAD OK NA NO NA
IDLE INSPECTION
STATION NO. 5
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
1100
460
460
2500HC
180
150
150
I. CO
0.30
3.80
3.80
2500C0
3.00
3.00
3.00
FAILURE
HC
PASS
PASS
COST
5.50
5.50
11.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0045
08/16/73 BAR:24.78 DB:72 WB:54
REL.HUM:32.3% NOX COR: .877
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
9.16
113.0
459.1
2.66
13.38
COLD STABILIZED
9.67
152.7
422.5
1.06
12.85
HOT TRANSIENT
7.09
98.8
393.4
2.04
15.59
1975 COMPOSITE
8.85
129.5
422.1
1.67
13.63
IDLE KEYMODE
5717
0.71
49
802
1620
0.70
LOW CR. KEYMODE
4199
3.93
577
435
495
3.95
HI. CR. KEYMODE
3958
3.28
1453
441
525
3.30
2500 RPM
340
4.40
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0082
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
19 75 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
08/20/73 BAR:24.97 DB:79 WB:59
REL.HUM:31.9% NOX COR: .919
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
11.85
12.68
9.33
11.58
114.5
161.7
101.8
135.2
400.9
371.1
348.5
371.1
2.16
1.03
1.77
1.47
14.40
13.39
16.55
14.36
11025
4030
3675
7.02
3.50
3.07
32
605
1502
930
410
342
850
285
240
230
7.00
3.45
3.15
4.30
AUTOMOTIVE TESTING LABORATORIES,INC.
19900, E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 038
1966 FORD GALA 390 4000LBS
8CYL 4BBL AUTOMATIC 054529 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
=== MAINTENANCE STATUS
==:
I. CO
I.RPM
TIM DWL PCV A.
.CL
FROM
OWNER
3.00
+0120
+04 +01 OK
OK
FROM
INSP.
3.00
+0120
+04 +01 OK
OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 6
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJI
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
190
2500HC
220
190 220
I.CO 2500CO
1.60 3.60
1.60 3.60
FAILURE COST
PASS 4.50
PASS
4.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0049
08/16/73 BAR:24.77 DB:78 WB:57
REL.HUM:28.62 NOX COR: .891
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
HC
9.06
8.04
7.22
8.02
CO
190.8
172.6
139.8
167.3
C02
671.6
593.2
596.6
610.5
NOX
4.38
2.25
4.45
3.31
MPG
8.90
10.01
10.61
9.91
LHC
SHC
SCO
IDLE KEYMODE
3745
3.76
105
434
560
3.15
LOW CR. KEYMODE
4115
4.75
1017
426
520
4.40
HI. CR. KEYMODE
3575
3.59
1919
299
345
3.45
2500 RPM
485
6.00
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0049
08/16/73 BAR:24.77 DB:78 WB:57
REL.HUM:28.6% NOX COR: .891
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
9.06
8.04
7.22
8.02
190.8
172.6
139.8
167.3
671.6
593.2
596.6
610.5
4.38
2.25
4.45
3.31
8.90
10.01
10.61
9.91
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3745
4115
3575
3.76
4.75
3.59
105
1017
1919
434
426
299
560
520
345
485
3.15
4.40
3.45
6.00
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 039
1968 PONT VENT 428 4500LBS
8CYL 4BBL AUTOMATIC 069716 MILES
TUNE UP EVALUATION
HAS: EMC, NO EVC, PCV
============================== MAINTENANCE STATUS ==============================
I. CO I.RPM TIM DWL PCV A.CL
FROM OWNER 3.60 +0150 +€3 +03 OK OK
FROM INSP. 1.60 -0080 +00 +01 OK OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
STATION NO. 5
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC
550
200
200
2500HC
150
110
110
I.CO 2500C0
4.00 1.70
2.40 2.40
2.40
2.40
FAILURE
HC
PASS
PASS
COST
5.50
5.50
11.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0062
08/17/73 BAR:24.75 DB:75 WB:56
REL.HUM:31.8% NOX COR: .893
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.44
5.02
3.87
4.58
86.0
127.7
78.3
105.3
484.0
473.4
437.6
465.7
2.89
1.36
2.93
2.12
14.06
12.91
15.54
13.80
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3464
3156
3147
3.88
2.07
3.49
111
1594
1384
330
318
286
530
480
410
285
3.60
2.00
3.40
2.30
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0083
08/20/73 BAR:24.94 DB:78 WB:62
REL.HUM:42.6% NOX COR: .991
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.71
4.71
4.11
4.75
108.1
109.3
76.8
100.0
526.0
512.4
454.7
499.2
3.33
2.20
3.70
2.85
12.47
12.74
15.14
13.27
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3240
3234
3101
1.72
2.98
3.18
107
1421
1602
322
356
289
240
180
200
140
1.80
3.00
2.80
1.90
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 040
1968 FORD CUST 302 4000LBS
8CYL 2BBL AUTOMATIC 019445 MILES
SEA LEVEL RETROFIT
HAS: EMC, NO EVC, PCV
MAINTENANCE STATUS
I.CO I.RPM TIM DWL PCV A.CL
FROM OWNER 2.80 +0050 +06 +03 BAD OK
FROM INSP. 1.88 +0050 +06 -07 OK OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
— IDLE INSPECTION
STATION NO. 10
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
2500HC
I.CO
2500CO
FAILURE
COST
400
180
2.00
1.00
HC
1.50
400
180
2.00
1.00
HC
1.50
400
100
1.20
1.10
HC
1.50
400
200
1.30
0.80
HC
1.50
14.34
260
140
0-80
0.70
PASS
20.34 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST .NO: C0048
08/16/73 BAR:24.78 DB:77 WB.\58
REL.HUM:33.3% NOX COR: .915
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.69
4.39
3.97
4.55
65.4
47.5
38.8
43.8
511.8
527.3
457.4
504.7
5.52
4.84
6.22
5.37
14.08
14.46
16.77
14.95
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3340
3589
3181
3.09
0.55
0.26
185
3112
3882
330
384
284
470
485
343
210
3.15
0.60
0.32
1.40
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO :C0063
08/17/73 BAR
REL.HUM:
: 24.75
27.8%
DB: 77
NOX COR
WB: 56
: .880
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.94
3.81
3.61
3.99
46.7
28.8
26.9
32.0
480.1
505.5
439.7
481.9
4.52
3.44
5.14
4.14
15.65
15.82
18.05
16.35
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3109
3463
3048
1.98
0.43
0.24
219
2821
3718
291
348
259
470
505
370
220
2.10
0.50
0.30
1.10
AUTOMOTIVE
TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 041
1970 CHEV NOVA 230 3000LBS
6CYL 2BBL AUTOMATIC 030980 MILES
SEA LEVEL RETROFIT
HAS: EMC, NO EVC, PCV
MAINTENANCE STATUS
I.CO I.RPM TIM
DUL
PCV A.CL CHOKE A.PMP MISF.
FROM OWNER
8.20
+0100
+16 -13
BAD
OK
OK
OK
NO
FROM INSP.
1.00
+0050
+16 -13
BAD
OK
OK
OK
NO
IDLE INSPECTION
—
STATION NO.
2
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
250
50
7.00
0.60
BOTH
5.50
AFTER I.RPM ADJUST
200
50
7.50
1.00
BOTH
3.30
AFTER I.MX/TM
ADJ1
120
25
1.40
0.50
PASS
3.30
AFTER I.MX/TM
AD J 2
REPAIRS
FINAL INSPECTION
120
25
1.40
0.50
PASS
NOXC
NA
NA
12.10 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:COOA7
08/16/73 BAR:24.78 DB:75 WB:56
REL.HUM:31.8% NOX COR: .892
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
4.93
72.5
435.4
4.01
15.77
COLD STABILIZED
4.60
64.0
417.3
2.97
16.73
HOT TRANSIENT
3.95
53.3
366.0
4.30
19.27
1975 COMPOSITE
4.49
62.8
406.9
3.56
17.14
IDLE KEYMODE
5848
8.96
68
708
960
8.70
LOW CR. KEYMODE
3987
1.50
1892
409
480
1.60
HI. CR. KEYMODE
3962
3.95
1299
368
430
3.95
2500 RPM
130
0.70
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0059
08/17/73 BAR:24.75 DB:74 WB:59
REL.HUM:43.3% NOX COR: .956
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.82
2.71
2.91
3.21
83.5
27.1
39.5
42.3
464.0
532.9
401.9
482.2
2.79
2.63
3.11
2.80
14.59
15.25
18.82
15.94
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2522
2178
4404
1.06
0.64
8.89
225
1380
307
252
147
358
440
225
500
75
1. 15
0.70
8.75
0.38
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 042
1969 PLYM BELV 318 3500LBS
8CYL 2BBL AUTOMATIC 039269 MILES
SEA LEVEL RETROFIT
HAS: EMC, NO EVC, PCV
I. CO I.RPM TIM DWL PCV A.CL
FROM OWNER 5.90 +0250 +00 +03 OK OK
FROM INSP. 2.30 -0130 +00 +03 OK OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
STATION NO.
IDLE INSPECTION
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
460
420
5.00
2.10
BOTH
2.50
AFTER I.RPM ADJUST
480
420
5.20
2.40
BOTH
2.50
AFTER I.MX/TM ADJ1
300
380
1.30
1.40
PASS
2.50
AFTER I.MX/TM ADJ2
280
300
1.20
2.00
PASS
2.50
REPAIRS
FINAL INSPECTION
300
300
1.30
2.00
PASS
10.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0061
08/17/73 BAR:24.74 DB:74 WB:54
REL.HUM:28.1% NOX COR: .866
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.03
5.72
4.67
5.49
81.5
74.6
56.9
71. 1
438.6
456.8
405.6
438.8
3.41
3.36
3.82
3.50
15.20
15.04
17.47
15.68
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
4667
4266
3929
6.27
0.87
2.48
78
2470
1635
481
461
358
640
665
500
2500 RPM
400
5.90
0.95
2.45
2.30
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0078
08/20/73 BAR: 24.99 DB-.74 WB-.56
REL.HUM:33.8% NOX COR: .896
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.28
4.83
4.01
4.91
87.8
42.4
33.9
49.5
447.7
477.4
425.2
456.7
3.04
3.64
4.25
3.68
14.71
15.92
18. 13
16.19
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3940
4373
4093
2.54
0.43
2.23
112
2609
1661
379
459
376
295
370
298
165
2.55
0.45
2.30
1.60
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 043
1971 FORD MAVE 170 2750LBS
6CYL 2BBL 3 SPEED 020583 MILES
SEA LEVEL RETROFIT
HAS: EMC, EVC, PCV
===s=»=======j===========i=====i== MAINTENANCE STATUS =============================
I. CO I.RPM TIM DWL PCV A.CL
FROM OWNER 6.10 +0060 +00 +04 OK BAD
FROM INSP. 6.10 +0060 +00 +04 OK BAD
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 4
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
320
320
2500HC
160
160
I. CO
3.40
3.40
2500CO
1.50
1.50
FAILURE
PASS
PASS
COST
5.00
5.00 TOT.
* A A 1c kit 4c A felt ** AAAAAAAA A A AA AAA
TEST NO:COO64
AS RECEIVED FROM OWNER ***************************
08/17/73 BAR:24.75 DB:77 WB:62
REL.HUM:45.2% NOX COR:1.002
HC
CO
CO 2
NOX
MPG
COLD
TRANSIENT
7.71
65.5
270.9
2.68
22.36
COLD
STABILIZED
5.25
63.9
281.6
2.18
22.34
HOT
TRANSIENT
4.94
57.2
252.2
2.70
24.89
1975
COMPOSITE
5.68
62.4
271.2
2.43
23.00
LHC
SHC
SCO
IDLE KEYMODE 4497
LOW CR. KEYMODE 3879
HI. CR. KEYMODE 3912
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
5.99
56
445
730
6.90
1.54
1830
463
800
2. 10
2.09
1777
480
800
2.30
640
2.80
TEST NO:C0064
08/17/73 BAR:24.75 DB:77 WB:62
REL.HUM:45.2% NOXCOR:1.002
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.71
5.25
4.94
5.68
65.5
63.9
57.2
62.4
270.9
281.6
252.2
271.2
2.68
2. 18
2. 70
2.43
22.36
22.34
24.89
23.00
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4497
3879
3912
5.99
1.54
2.09
56
1830
1777
445
463
480
730
800
800
640
6.90
2. 10
2.30
2.80
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 044
1967 CHEV CAPR 327 4000LBS
8CYL 4BBL AUTOMATIC 046046 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
MAINTENANCE STATUS
I.CO I.RPM TIM DWL PCV A.CL
FROM OWNER 4.47 +0025 +02 +04 BAD OK
FROM INSP. 4.47 +0025 +02 +04 BAD OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
STATION NO. 9
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
350
2500HC
300
350 300
I. CO
1.90
2500C0
6.00
FAILURE COST
PASS 4.00
1.90 6.00
PASS
4.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0072
08/17/73 BAR:24.77 DB:71 WB:59
REL.HUM:51.5% NOX COR: .978
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
8.59
149.1
424.1
2.44
12.99
COLD STABILIZED
7.60
157.1
408. 3
1.23
13. 11
HOT TRANSIENT
6.97
132.5
422.5
2.69
13.64
1975 COMPOSITE
7.63
148.6
415.6
1.89
13.23
IDLE KEYMODE
5826
5.03
56
744
1100
4.60
LOW CR. KEYMODE
4358
3.75
1138
508
700
3.60
HI. CR. KEYMODE
4044
3.09
1636
423
580
3.00
2500 RPM
640
6.60
* & rk ie A * A A & A & A A A A A A A A A A A A A A
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0072
08/17/73 BAR:24.77 DB:71 WB:59
REL.HUM:51.5% NOX COR: .978
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
8.59
7.60
6.97
7.63
149.1
157.1
132.5
148.6
424. 1
408.3
422.5
415.6
2.44
1.23
2.69
1.89
12.99
13.11
13.64
13.23
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
5826
4358
4044
5.03
3.75
3.09
56
1138
1636
744
508
423
1100
700
580
640
4.60
3.60
3.00
6.60
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 045
1972 DODG DART 225 3000LBS
6CYL 1BBL AUTOMATIC 005414 MILES-
SEA LEVEL RETROFIT
HAS: EMC, EVC, PCV
MAINTENANCE STATUS ==============================
I.CO I.RPM TIM DWL
FROM OWNER 3.60 +0550 +09 -12
FROM INSP. 3.80 -0060 +01 +03
PCV A.CL CHOKE A.PMP MISF. NOXC
OK OK OK NA NO NA
OK BAD OK NA NO NA
IDLE INSPECTION
STATION NO. 3
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
600
140
240
240
2500HC
250
70
150
150
I. CO
3.50
1.30
3.20
3.20
2500CO
1.50
2.25
2.30
2.30
FAILURE
HC
HC
PASS
PASS
COST
0.00
0.00
0.00
12.00
12.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0066
08/17/73 BAR:24.76 DB:72 WB:54
REL.HUM:32.3% NOX COR: .878
SCO
HC
CO
CO 2
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.22
3.49
3.34
3.81
145.2
75.9
89.8
94.2
356.0
370.4
329.0
355.9
2.59
3. 13
3.33
3.07
14.83
17.79
18.53
17.26
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3454
3341
4196
4.24
4.22
10.09
95
2321
281
331
703
415
540
460
600
320
4.10
3.20
10.00
2.40
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0086
08/21/73 BAR:24.85 DB:78 WB:60
REL.HUM:36.8% NOX COR: .947
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.03
3.22
3.32
3.63
141.4
73.8
90.5
92.6
363.8
373.3
330.8
359.5
2.92
3.20
3.32
3.17
14.80
17.83
18.42
17.25
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3450
3172
4163
4. 21
3.86
10.23
75
1103
189
336
320
402
270
250
320
170
4. 10
2.70
9.80
2. 10
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 046
1965 PLYM VALI 225 3000LBS
6CYL 1BBL 3 SPEED 085428 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
STATUS ===
I. CO
I.RPM
TIM
DWL
PCV A.CL
CHOKE
A.PMP
MISF.
FROM
OWNER
3.10
-0140
+10
-01
OK BAD
BAD
NA
YES
FROM
INSP.
3.10
-0140
+10
-01
OK BAD
BAD
NA
YES
IDLE INSPECTION
l————————
.1 ¦ M
M m _ I, ,
NOXC
NA
NA
STATION NO. 9
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
350
350
2500HC
250
250
I. CO
4.00
4.00
2500CO
5.00
5.00
FAILURE
PASS
PASS
COST
0.00
4.00
4.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0071
08/17/73 BAR: 24.77 DB-.7I WB-.56
REL.HUM:41.1% NOX COR: .918
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
37.95
8.97
7.73
14.69
186.6
106.5
92.4
119.3
289.2
321.0
295.4
307.2
1.35
1.29
1.83
1.45
12.67
17.24
19.14
16.46
6158
4495
3881
3.32
5.26
3.77
47
903
1117
812
435
359
1300
580
420
800
3.50
5. 10
3.80
5.30
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0071
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
08/17/73 BAR:24.77 DB:71 WB:56
REL.HUM:41.1% NOX COR: .918
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
37.95
8.97
7.73
14.69
186.6
106.5
92.4
119.3
289.2
321.0
295.4
307.2
1.35
1.29
1.83
1.45
12.67
17.24
19. 14
16.46
6158
4495
3881
3.32
5.26
3.77
47
903
1117
812
435
359
1300
580
420
800
3.50
5.10
3.80
5.30
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 048
1967 MERC STAW 390 4500LBS
8CYL 2BBL AUTOMATIC 064033 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
MAINTENANCE STATUS ==
I. CO I.RPM TIM DWL PCV A.CL
FROM OWNER 0.70 -0035 -24 +03 OK OK
FROM INSP. 0.70 -0035 -24 +03 OK OK
CHOKE
OK
OK
A.PMP
NA
NA
MISF. NOXC
YES NA
YES NA
IDLE INSPECTION
STATION NO. 10
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
550
550
2500HC
220
220
I. CO
0.40
0.40
2500C0
1.50
1.50
FAILURE
PASS
PASS
COST
1.50
1.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0080 08/20/73 BAR:24.99 DB:75 WB:59
REL.HUM:40.6% NOX COR: .945
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
9. 11
92.4
708.3
9.14
10.09
COLD STABILIZED
9.33
46.5
735.3
8.82
10.63
HOT TRANSIENT
8.42
46.3
584.4
9.50
13.02
1975 COMPOSITE
9.03
56.1
687.8
9.08
11.07
IDLE KEYMODE
8481
0.87
150
1591
1450
0.75
LOW CR. KEYMODE
4201
1.41
2998
492
375
1.40
HI. CR. KEYMODE
3742
1.70
3161
360
270
1.80
2500 RPM
185
1.30
AS RECEIVED FROM
INSPECTION ************************
TEST NO:COO80
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
08/20/73 BAR:24.99 DB:75 WB:59
REL.HUM:40.6% NOX COR: .945
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
9. 11
9.33
8.42
9.03
92.4
46.5
46.3
56.1
708.3
735.3
584.4
687.8
9. 14
8.82
9.50
9.08
10.09
10.63
13.02
11.07
8481
4201
3742
0.87
1.41
1.70
150
2998
3161
1591
492
360
1450
375
270
185
0.75
1.40
1.80
1.30
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 049
1967 CHEV CAMA 250 3000LBS
6CYL 1BBL 4 SPEED 076864 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
===,=========================,=,= MAINTENANCE STATUS ==============================
I. CO I.RPM TIM DWL PCV A.CL
FROM OWNER 7.40 40180 +04 -08 BAD BAD
FROM INSP. 10.30 +0750 +21 +02 BAD BAD
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA YES NA
IDLE INSPECTION
STATION NO. 6
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
260
****
7.00
*****
BOTH
4.50
AFTER I.RPM ADJUST
300
2000
4.00
10.00
BOTH
1.50
AFTER I.MX/TM ADJ1
300
2000
4.00
10.00
BOTH
1.50
AFTER I.MX/TM ADJ2
2000
2000
6.60
10.00
BOTH
3.00
REPAIRS
FINAL INSPECTION
2000
2000
6.60
10.00
BOTH
10.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0077
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
08/20/73 BAR:24.99 DB:74 WB:57
REL.HUM:36.8% NOX COR: .913
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
18.80
15.59
12.00
15.27
211.8
232.1
202.8
219.7
202.0
212.5
184.5
202.5
0.24
0.12
0.18
0. 16
14.98
14.21
16.46
14.95
6436
8164
6646
8.15
12.95
12.05
40
82
104
456
762
686
430
730
640 •
****
8.40
*****
*****
kkkkk
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0110
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
08/22/73 BAR:24.79 DB:74 WB:60
REL.HUM:46.5% NOX COR: .977
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
26.11
27.72
18.46
24.81
241.1
320.8
222.3
276.8
238.7
262.3
201.4
240.5
0.36
0.18
0.37
0.27
12.72
10.43
14.62
11.82
39195
13304
4497
9.62
12.52
0.46
18
60
1610
1645
1081
476
****
1100
1040
850
kkkkk
1.60
6.00
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 051
1969 OLDS DELT 455 4500LBS
8CYL 2BBL AUTOMATIC 064800 MILES
IDLE INSPECTION ONLY
HAS: EMC, NO EVC, PCV
FRCM OWNER
FROM INSP.
I.CO I.RPM
4.90 -0065
4.90 -0065
== MAINTENANCE STATUS ============.=======>==========
TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
-05 +03 OK OK OK NA NO NA
-05 +03 OK OK OK NA NO NA
IDLE INSPECTION
STATION NO. 1
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC 2500HC
180 120
180 120
I.CO 2500CO
5.00 3.00
5.00 3.00
FAILURE COST
PASS 2.50
PASS
2.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0087
08/21/73 BAR:24.85 DB:72 WB:58
REL.HUM:45.1% NOX COR: .948
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
4.69
86.8
546.9
4.43
12.75
COLD STABILIZED
4.22
84. 1
585.4
3.40
12.19
HOT TRANSIENT
3.56
69.0
494.7
4.54
14.49
1975 COMPOSITE
4.13
80.5
552.2
3.93
12.88
IDLE KEYMODE
3509
5.42
50
309
230
4.90
LOW CR. KEYMODE
2965
1.94
1419
277
215
1.70
HI. CR. KEYMODE
2551
1.39
1866
204
140
1.50
2500 RPM
140
1.90
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0087
08/21/73 BAR: 24.85 DB:72 WB:58
REL.HUM:45.1% NOX COR: .948
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.69
4.22
3.56
4.13
86.8
84.1
69.0
80.5
546.9
585.4
494.7
552.2
4.43
3.40
4.54
3.93
12.75
12.19
14.49
12.88
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3509
2965
2551
5.42
1.94
1.39
50
1419
1866
309
277
204
230
215
140
140
4.90
1.70
1.50
1.90
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 053
1964 DODG POLA 318 4000LBS
8CYL 2BBL AUTOMATIC 042474 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
============================== MAINTENANCE STATUS ==============================
I. CO I.RPM TIM DWL PCV A.CL CHOKE A. PMP MISF. NOXC
FROM OWNER 1.30 +€010 +05 +01 OK BAD OK NA NO NA
FROM INSP. 0.19 +0000 +<30 +02 OK BAD OK NA NO NA
IDLE INSPECTION
STATION NO. 8
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
650
650
360
360
2500HC
350
350
300
300
I. CO
7.00
7.00
0.20
0.20
2500CO
1.40
1.40
1.20
1.20
FAILURE
BOTH
BOTH
PASS
PASS
COST
3.50
2.00
2.50
8.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0088 08/21/73 BAR: 24.85 DB:75 WB:59
REL.HUM:40.7% NOX COR: .948
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
8.60
109.6
510.4
3.06
12.54
COLD STABILIZED
7.46
101.8
470.5
2.81
13.62
HOT TRANSIENT
6.13
70.2
462.7
4.49
15.03
1975 COMPOSITE
7.33
94.7
476.7
3.33
13.73
IDLE KEYMODE
6000
7.99
51
649
580
7.75
LOW CR. KEYMODE
3687
0.69
2234
387
300
0.75
HI. CR. KEYMODE
3655
2.33
1711
328
250
2.35
2500 RPM
160
1.55
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0107 08/22/73 BAR:24.80 DB:74 WB:60
REL.HUM:46.5% NOX COR: .977
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.40
5.50
4.84
5.72
104.1
45.5
45.8
57.8
530.8
511.4
462.9
502.0
3.39
3.51
4.73
3.82
12.41
14.83
16.19
14.58
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3797
3765
3592
0.22
0.66
1.94
168
2362
2012
531
491
405
460
340
260
600
0.25
0.25
2.00
5.20
AUTOMOTIVE TESTING LABORATORIES.INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 055
1966 FORD MUST 200 3000LBS
6CYL 1BBL AUTOMATIC 054749 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
=========== MAINTENANCE STATUS =======
I. CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 6.00 -0040 +00 -07 OK OK OK NA NO NA
FROM INSP. 5.11 -0025 -05 -07 OK OK OK NA NO NA
IDLE INSPECTION
STATION NO. 7
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
240
220
5.10
3.40
CO
2.50
AFTER I.RPM ADJUST
240
220
4.40
4. 10
CO
2.50
AFTER I.MX/TM ADJ1
220
120
2.10
2.40
PASS
2.50
AFTER I.MX/TM ADJ2
200
130
2.40
2.40
PASS
2.50
REPAIRS
FINAL INSPECTION
200
200
1.20
2.40
PASS
10.00 TOT.
*************************** as RECEIVED FROM OWNER ***************************
TEST NO:C0089 08/21/73 BAR:24.85 DB:78 WB:59
REL.HUM:34.0% NOX COR: .927
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
9.41
3.53
6.30
5.53
179.3
156.5
161.4
162.6
323.7
293.0
260.6
290.4
1. 18
0.62
0.61
0.73
14.02
16. 19
16.67
15.81
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
5237
5673
4889
6.24
9.40
7.66
67
147
318
682
696
536
550
575
395
2500 RPM
600
5.80
9.00
7.60
9.80
************************* as RECEIVED FROM INSPECTION ************************
TEST NO:C0109
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
08/22/73 BAR:24.79 DB:76 WB:60
REL.HUM:41.4% NOX COR: .963
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
10.65
6.47
7.12
7.53
210.5
163.5
161.8
172.8
277.3
274.0
249.5
267.9
0.59
0.57
0.54
0.57
13.88
16.15
16.92
15.82
5706
6312
5379
5.46
9.76
7.96
77
157
389
891
890
676
640
680
470
700
5.00
9.50
7.90
*****
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 056
1964 CHEV BELA 230 3500LBS
6CYL 1BBL AUTOMATIC 046660 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
FROM OWNER
FROM INSP.
I. CO
6.30
3.45
I.RPM
+0100
-0050
MAINTENANCE STATUS
TIM
-18
-18
DWL
+04
-09
PCV
OK
OK
A.CL
OK
OK
CHOKE
OK
OK
A.PMP
NA
NA
MISF.
YES
NO
NOXC
NA
NA
— IDLE INSPECTION
STATION NO. 10
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I. HC
640
580
580
2500HC
160
240
240
I. CO 2500CO
7.60 1.70
0.50 1.80
0.50
1.80
FAILURE
CO
PASS
PASS
COST
0.00
1.50
1.50 TOT.
*************************** as RECEIVED FROM OWNER ***************************
TEST NO:C0102
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
08/22/73 BAR:24.80 DB:76 WB:58
REL.HUM:35.4% NOX COR: .922
SCO
HC
CO
CO 2
NOX
MPG
LHC
SHC
10.24
8.50
7.67
8.63
223.0
205.0
193.1
205.4
378.6
358.4
322.1
352.5
2.06
1.81
1.94
1.90
11.70
12.59
13.71
12.68
5606
8193
6232
6.77
13.82
12.60
155
53
89
739
841
694
785
880
760
1800
6.50
** ***
*****
2.40
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0121
08/23/73 BAR:24.77 DB:77 WB:60
REL.HUM:39.1% NOX COR: .956
HC
CO
CO 2
NOX
MPG
COLD
COLD
HOT
1975
TRANSIENT
STABILIZED
TRANSIENT
COMPOSITE
8.47
7.74
6.66
7.59
189.9
180.9
173.2
180.7
384.2
346.4
301.9
342.0
1.84
1.52
1.54
1.59
12.55
13.59
14.96
13.71
LHC
SHC
SCO
IDLE KEYMODE
4900
3.79
84
722
740
3.50
LOW CR. KEYMODE
7066
12.99
74
871
960
*****
HI. CR. KEYMODE
6324
12.68
97
802
840
*****
2500 RPM
300
2.10
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 057
1971 VOLK SEDA 97 2000LBS
4CYL 1BBL 4 SPEED 034981 MILES
TUNE UP EVALUATION
HAS: EMC, NO EVC, PCV
3aaaa=33asa
aaaaaasna
aaaamaa
»»= MAINTENANCE STATUS
aa:
I. CO
I.RPM
TIM DWL PCV A,
.CL
FROM OWNER
6.10
+0030
+00 -05 NA
OK
FROM INSP.
2.60
+0050
+00 -02 NA
OK
CHOKE A.PMP MISF. NOXC
OK. NA NO NA
OK NA NO NA
IDLE INSPECTION —
STATION NO. 4
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TN ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
85
60
60
2500HC
55
40
40
I. CO
4.90
2.40
2.40
2500CO
3.70
1.80
1.80
FAILURE
CO
PASS\
PASS
COST
5.00
1.00
6.00 TOT.
* A*** A ****** *** A* A** *******
TEST NO:C0099
AS RECEIVED FROM OWNER ***************************
08/22/73 BAR:24.80 DB:72 WB:59
REL.HUM:48.6% NOX COR: .970
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.71
5.83
4.40
5.41
92.1
103.3
75.4
93.2
269.8
277 .7
243.3
266.5
1.73
0.93
1.54
1.27
20.58
19.42
23.71
20.71
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
4468
3672
2968
6.55
3.87
2.72
71
691
1574
318
341
252
255
250
190
2500 RPM
160
6.20
3.80
2.95
3.50
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0112
08/23/73 BAR: 24.82 DB:73 WB:58
REL.HUM:42.5% NOX COR: .942
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.59
3.93
3.61
4. 19
75.5
70.3
65.8
70.1
264.0
292.2
238.1
271.3
1.87
1.05
1.39
1.32
22.24
21.45
25.23
22.56
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3412
3918
3152
2.88
3.42
2.56
88
844
1706
324
416
291
278
330
245
150
2.80
3.40
2.58
2.30
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 059
1965 CHEV STAW 327 4000LBS
8CYL 4BBL AUTOMATIC 079730 MILES
TUNE UP EVALUATION
HAS: NO EMC, NO EVC, PCV
===================
========
== MAINTENANCE STATUS ==========
I. CO
I. RPM
TIM DWL
PCV
A.CL CHOKE
A.PMP
MISF.
FROM OWNER 10-90
+0190
-20 -01
OK
BAD OK
NA
NO
FROM INSP. 3.99
-0010
-04 +01
OK
OK OK
NA
NO
IDLE INSPECTION
STATION NO. 1
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
850
300
8.00
4.00
BOTH
2.50
AFTER I.RPM ADJUST
800
350
6.30
4.10
BOTH
0.00
AFTER I.MX/TM ADJ1
720
300
1.60
3.00
PASS
5.00
AFTER I.MX/TM ADJ2
REPAIRS
5.35
FINAL INSPECTION
720
300
1.60
4.10
PASS
12.85
NOXC
NA
NA
***************************
TEST NO:C0101
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
AS RECEIVED FROM OWNER ***************************
08/22/73 BAR:24.80 DB:71 WB:58
REL.HUM:47.9% NOX COR: .956
SCO
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
HC
CO
C02
NOX
MPG
LHC
SHC
26.49
31.53
17.80
26.67
239.7
378.0
208.9
302.1
423.0
348.5
363.7
368.3
1.32
0.32
1.33
0.81
10.08
8.54
11.90
9.61
9376
4438
3806
11.65
5.57
3.76
25
554
1246
750
529
408
720
500
355
595
*****
5.40
3.70
7.80
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:CO120
08/23/73 BAR:24.78 DB:78 WB:63
REL.HUM:45.8% NOX COR:1.019
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
9.13
7.67
6.92
7.77
141.5
132.2
96.8
124.3
427.4
412.9
412.9
416.0
2.50
1.69
3.20
2.28
13.12
13.81
15.17
14.01
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
5188
4127
4571
4.23
3.31
4.17
56
1236
1183
722
558
606
840
550
600
820
4.00
3.20
4.00
7.00
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 060
1970 CADI DEVI 472 5000LBS
8CYL 4BBL AUTOMATIC 045946 MILES
IDLE INSPECTION ONLY
HAS: EMC, NO EVC, PCV
FROM OWNER
FROM INSP.
I. CO I. REM
0-69 +0010
0.69 40010
===== MAINTENANCE STATUS ==========
TIM DWL PCV A.CL CHOKE
-02 +02 OK BAD OK
-02 +02 OK BAD OK
A.PMP MISF. NOXC
NA NO NA
NA NO NA
STATION NO. 6
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC 2500HC
80 50
80
50
I. CO 2500CO
0.90 1.40
0.90 1.40
FAILURE COST
PASS 4.50
PASS
4.50 TOT.
***************************
TEST NO:C0132
AS RECEIVED FROM OWNER ***************************
08/24/73 BAR:24.70 DB:78 WB:60
REL.HUM:36.9% NOX COR: .950
CO
262.8
132.3
180.7
173.1
C2
617.9
712.5
551.0
647.9
NOX
1.92
2.18
2.53
2.22
MPG
8.43
9.52
10.46
9.50
LHC
SHC
SCO
HC
COLD TRANSIENT 8.16
COLD STABILIZED 4.69
HOT TRANSIENT 5.16
1975 COMPOSITE 5.55
IDLE KEYMODE 2031
LOW CR. KEYMODE 3225
HI. CR. KEYMODE 3385
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
0.78
153
425
130
0.75
2.07
1513
533
280
2.00
4.56
868
498
250
4.20
90
2.30
TEST NO:CO132
08/24/73 BAR:24.70 DB:78 WB:60
REL.HUM:36.9% NOX COR: .950
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
8.16
4.69
5.16
5.55
262.8
132.3
180.7
173.1
617.9
712.5
551.0
647.9
1.92
2.18
2.53
2.22
8.43
9.52
10.46
9.50
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2031
3225
3385
0.78
2.07
4.56
153
1513
868
425
533
498
130
280
250
90
0.75
2.00
4.20
2.30
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 061
1972 CHEV VEGA 140 2500LBS
4CYL 2BBL 4 SPEED 025879 MILES
IDLE INSPECTION ONLY
HAS: EMC, EVC, PCV
MAINTENANCE STATUS ==============================
I. CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 5.30 -0200 -K)0 -02 OK OK OK NA NO NA
FROM INSP. 5.30 -0200 +00 -02 OK OK OK NA NO NA
IDLE INSPECTION
STATION NO. 2
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
180
180
2500HC
95
95
I.CO 2500CO
2.50 2.75
2.50 2.75
FAILURE COST
PASS 5.00
PASS
5.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0090
08/21/73 BAR:24.85 DB:78 WB:60
REL.HUM:36.8% NOX COR: .947
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
10.92
8.28
5.45
8.05
209.9
156.6
132.4
161.1
266.9
283. 1
207. 1
258.6
0.53
0.84
0.56
0.70
14. 11
16.04
20.60
16.59
6825
5536
4800
5.83
9.46
9.05
38
207
221
528
496
414
345
335
275
190
5.45
9.15
8.85
4.50
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0090
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
08/21/73 BAR:24.85 DB:78 WB:60
REL.HUM:36.8% NOX COR: .947
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
10.92
8.28
5.45
8.05
209.9
156.6
132.4
161. 1
266.9
283.1
207.1
258.6
0.53
0.84
0.56
0.70
14.11
16.04
20.60
16.59
6825
5536
4800
5.83
9.46
9.05
38
207
221
528
496
414
345
335
275
190
5.45
9.15
8.85
4.50
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 063
1967 PLYM FURY 318 4000LBS
8CYL 2BBL AUTOMATIC " 042005 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
============================= MAINTENANCE STATUS =============¦=================
I. CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 5.00 +0240 +12 +07 OK OK OK NA YES NA
FROM INSP. 2.40 -0200 +12 -02 OK BAD OK NA NO NA
IDLE INSPECTION
STATION NO. 8
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
340
520
400
2500HC
1400
1700
300
I.CO 2500CO
1.90 1.60
0.20 1.60
0.20
1.30
FAILURE
HC
HC
PASS
COST
3.50
2.00
5.50
11.00 TOT.
*************************** as RECEIVED FROM OWNER ***************************
TEST NO:C0103
08/22/73 BAR:24.80 DB:75 WB:59
REL.HUM:40.8% NOX COR: .948
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
13.17
227.3
354.8
1.01
11.
82
COLD STABILIZED
10.77
189.3
365.2
1.02
12.
78
HOT TRANSIENT
6.59
84.1
367.2
3.39
17.
12
1975 COMPOSITE
10.11
168.1
363.6
1.68
13.
50
IDLE KEYMODE
6013
5.76
70
795
760
5.00
LOW CR. KEYMODE
5220
4.87
857
659
595
4.75
HI. CR. KEYMODE
4302
3.19
1396
443
360
3.25
2500 RPM
1900
2.90
*************************
AS RECEIVED FROM
INSPECTION
************************
TEST NO:C0122
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
08/23/73 BAR:24.76 DB:74 WB:60
REL.HUM:46.5% NOX COR: .978
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
16.91
10.00
6.89
10.58
237.2
169.9
82.6
159.8
363.8
352.6
357.1
356.2
1.11
0.79
3.35
1.57
11.27
13.67
17.51
13.90
6157
5378
4442
2.86
4.29
2.93
61
998
1612
1124
895
607
800
760
420
520
2.40
4.00
2.80
2.60
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 064
1970 AMMO REBE 232 3500LBS
6CYL 1BBL AUTOMATIC 064875 MILES
IDLE INSPECTION ONLY
HAS: EMC, NO EVC, PCV
============================== MAINTENANCE STATUS ==============================
I. CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 4.65 -0010 +01 +01 OK OK OK NA NO NA
FROM INSP. 4.65 -0010 +01 +01 OK OK OK NA NO NA
IDLE INSPECTION
STATION NO. 6
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC 2500HC
200 160
200 160
I.CO 2500CO
3.20 1.50
3.20 1.50
FAILURE COST
PASS 4.50
PASS
4.50 TOT.
*************************** as RECEIVED FROM OWNER ***************************
TEST NO:C0111
08/23/73 BAR:24.82 DB:74 WB:58
REL.HUM:40.0% NOX COR: .935
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.10
4.55
3.71
4.43
67.6
76.8
52.2
68.1
440.1
395.9
379.3
400.5
6.96
3.93
6.34
5.24
15.83
16.77
18.83
17.08
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
5930
4048
3593
5.02
1.46
1.40
127
2646
3074
617
337
253
1120
480
320
305
4.80
1.60
1.52
2.70
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C01U
08/23/73 BAR:24.82 DB:74 WB:58
REL.HUM:40.0% NOX COR: .935
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.10
4.55
3.71
4.43
67.6
76.8
52.2
68.1
440.1
395.9
379.3
400.5
6.96
3.93
6.34
5.24
15.83
16.77
18.83
17.08
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
5930
4048
3593
5.02
1.46
1.40
127
2646
3074
617
337
253
1120
480
320
305
4.80
1.60
1.52
2.70
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 065
1970 CHRY NEWP 383 4500LBS
8CYL 2BBL AUTOMATIC 036717 MILES
IDLE INSPECTION ONLY
HAS: EMC, NO EVC, PCV
MAINTENANCE STATUS
FROM OWNER
FROM INSP.
I. CO
8.90
2.35
I.RPM
+0160
+0050
TIM DWL
+07 +02
+00 +03
PCV
OK
OK
A.CL
BAD
OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 3
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
700
700
150
150
2500HC
200
200
210
210
I. CO
9.40
9.40
3.50
3.50
2500CO
2.00
2.00
2.20
2.20
FAILURE
BOTH
BOTH
PASS
PASS
COST
0.00
0.00
0.00
17.20
17.20 TOT.
***************************
TEST NO:C0113
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
AS RECEIVED FROM OWNER ***************************
08/23/73 BAR:24.82 DB:74 WB:59
REL.HUM:43.2% NOX COR: .955
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
11.81
12.55
8.97
11.40
142.1
169.7
131.0
153.2
584 .3
561.8
531.3
558.0
4.40
3.87
4.60
4.18
10.54
10.26
11.63
10.67
11735
3636
3523
9.32
0.75
1.51
38
2174
1422
750
478
393
860
365
260
170
9.60
0.85
1.65
1.80
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0131
08/24/73 BAR:24.70 DB:76 WB:62
REL.HUM:47.7% NOX COR:1.Oil
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
9.03
5.67
4.97
6.18
147.1
106.4
90.5
110.5
615.2
615.2
557.0
599.1
4.56
3.79
5.21
4.34
10.18
11.13
12.46
11.24
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2849
2954
2788
2.48
0.89
1.25
76
2434
2463
450
459
381
170
220
160
75
2.40
0.90
1.20
1.00
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 066
1970 PLYM DUST 318 3000LBS
8CYL 2BBL 3 SPEED 037361 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
============================== MAINTENANCE STATUS ==============================
I.CO I.RPM TIM DWL PCV A.CL
FROM CWNER 8.90 +0110 +02 -02 OK BAD
FROM INSP. 3.80 -0125- +01 -02 OK BAD
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
STATION NO.
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
430
220
7.20
1.20
BOTH
2.50
320
180
6.20
1.20
CO
2.50
180
130
1.20
1.10
PASS
2.50
180
180
1.30
1.30
PASS
2.50
180
180
1.30
1.30
PASS
10.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0116
08/23/73 BAR:24.81 DB:77 WB:59
REL.HUM:36.2% NOX COR: .934
SCO
HC
CO
CO 2
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.67
7.31
5.56
6.69
61.6
81.5
57.4
70.7
409.9
419.2
367.4
402.9
3.22
2. 17
3.07
2.64
16.87
15.61
18.74
16.65
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
11181
3506
3593
9.66
1.21
1.94
30
1470
1647
748
402
413
765
315
345
2500 RPM
190
9.40
1.30
2.00
1.70
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0133
08/24/73 BAR:24.70 DB:78 WB:60
REL.HUM:36.9% NOX COR: .950
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.08
4.77
4.82
5.27
67.0
65.0
58.7
63.7
435.8
462.0
392.1
437.1
3.31
2.27
3.27
2.76
15.80
15.37
17.83
16.08
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4247
3137
3363
4.28
1.36
2.29
53
1367
1487
585
464
500
300
230
270
130
3.80
1.20
2.40
0.90
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 067
1971 CADI DEVI 472 5000LBS
8CYL 4BBL AUTOMATIC 041770 MILES
IDLE INSPECTION ONLY
HAS: EMC, EVC, PCV
============================= MAINTENANCE STATUS =============================
I. CO I. RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 2.70 -0200 +00 -K)2 OK OK OK OK NO NA
FROM INSP. 2.70 -0200 +00 +02 OK OK OK OK NO NA
IDLE INSPECTION —
STATION NO.
1
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
100
100
2500HC
40
40
I. CO
3.00
2500CO
1.00
FAILURE COST
PASS 2.50
3.00 1.00
PASS
2.50 TOT.
*** ************************
TEST NO:C0114
AS RECEIVED FROM OWNER ***************************
08/23/73 BAR:24.82 DB:75 WB:58
REL.HUM:37.7% NOX COR: .928
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.01
2.68
2.54
2.92
80.7
68.4
55.5
67.4
742.1
754.6
628.8
717.1
3.38
2.07
3.88
2.85
10.10
10.23
12.30
10.70
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2091
2325
1785
3.37
2.40
1.05
52
749
1535
337
341
249
175
205
105
40
2.90
2.10
0.93
0.40
************************* AS RECEIVED FROM INSPECTION ************************
TEST N0:C0114
08/23/73 BAR:24.82 DB:75 WB:58
REL.HUM:37.7% NOX COR: .928
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.01
2.68
2.54
2.92
80.7
68.4
55.5
67.4
742. 1
754.6
628.8
717.1
3.38
2.07
3.88
2.85
10.10
10.23
12.30
10.70
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2091
2325
1785
3.37
2.40
1.05
52
749
1535
337
341
249
175
205
105
40
2.90
2. 10
0.93
0.40
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 068
1968 OLDS CUTL 350 3500LBS
8CYL 2BBL AUTOMATIC 054881 MILES
IDLE INSPECTION ONLY
HAS: EMC, NO EVC, PCV
==================*=,===========, MAINTENANCE STATUS =======>=====.======»====:=====«==
I. CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 9.05 +0050 +05 +04 OK BAD OK NA NO NA
FROM INSP. 3.68 -0075 405 +04 OK OK BAD NA NO NA
IDLE INSPECTION
STATION NO. 2
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
650
300
7.00
3.20
BOTH
5.00
AFTER I.RPM ADJUST
600
300
7.00
7.20
BOTH
2.00
AFTER I.MX/TM ADJ1
500
300
5.00
6.00
BOTH
2.00
AFTER I.MX/TM ADJ2
600
350
2.00
5.00
BOTH
2.00
REPAIRS
FINAL INSPECTION
600
350
2.00
5.00
BOTH
101.00
11.00 TOT.
*************************** as RECEIVED FROM OWNER ***************************
TEST NO:C0115
08/23/73 BAR:24.82 DB:75 WB:59
REL.HUM.-40.7% NOX COR: .948
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
8.20
8.00
6.41
7.60
117.5
146.5
85.5
123.5
475.3
438.9
424. 1
442.4
3.20
1.68
3.65
2.55
12.98
12.82
15.39
13.49
8299
4449
3220
9.90
7.16
1.13
47
259
2083
858
607
385
1600
650
300
230
9.80
6.80
1.50
1.80
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* as RECEIVED FROM INSPECTION ************************
TEST NO:C0146
08/27/73 BAR:24.65 DB:78 WB:59
REL.HUM:34.1% NOX COR: .930
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.80
6.57
5.30
6.47
96.0
92.3
43.0
79.4
539.2
484.4
455.6
487.9
3.65
1.94
3.60
2.76
12.46
13.70
16.49
14.07
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
7391
4110
3307
3.50
1.99
0.84
77
1038
1937
1534
697
529
1400
410
210
340
4.00
1.80
0.80
1.40
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 069
1967 FORD LTD 390 4000LBS
8CYL 2BBL AUTOMATIC 048253 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
===== MAINTENANCE STATUS =======
FRCM OWNER
FROM INSP.
I.CO I.RPM
8.50 +0000
4.31 +0000
TIM DWL PCV A.CL CHOKE A. PMP MISF. NOXC
-04 +00 OK BAD OK NA NO NA
-05 -01 OK BAD OK NA NO NA
IDLE INSPECTION
STATION NO.
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
700
580
680
680
2500HC
150
180
240
240
I. CO
9.50
7.00
4.40
4.40
2500CO
2.60
3.60
3.80
3.80
FAILURE
CO
CO
PASS
PASS
COST
5.50
5.50
5.50
16.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0119
08/23/73 BAR:24.79 DB:79 WB:61
REL.HUM:37.6% NOX COR: .963
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
8.85
10. 16
6.88
8.98
80.0
120.1
72.9
98.6
443.3
448.2
399.6
433.7
4.44
3.29
4.17
3.77
14.91
13.31
16.62
14.44
11778
4104
3885
9.42
1.08
2.01
31
2187
2257
1313
630
548
1380
540
425
340
9.00
1. 10
2. 10
1.80
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0145
08/27/73 BAR:24.67 DB:79 WB:58
REL.HUM:29.4% NOX COR: .904
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
8.60
7.35
6.14
7.28
80.2
82. 1
65.8
77.2
536.2
479.7
453.3
484.2
5.22
3.33
4.66
4.09
12.92
14.09
15.46
14.17
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
6802
3907
3713
4.80
1.29
2.15
109
2139
2139
1106
688
598
1160
600
430
410
4.40
1.40
2.20
1. 70
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 070
1972 PONT CATA 400 4500LBS
8CYL 2BBL AUTOMATIC 016700 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, EVC, PCV
============================== MAINTENANCE STATUS =============================
I. CO I.RPM TIM DWL PCV A.CL CHOKE A. PMP MISF. NOXC
FROM OWNER 5.10 -0005 +02 -02 OK OK OK NA NO NA
FROM INSP. 1.50 -0035 -K)2 -02 OK OK OK NA NO NA
STATION NO. 10
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC
380
420
310
270
2500HC
50
120
110
110
I. CO
3.40
3.60
1.60
0.50
2500CO
0.40
3.00
0.90
0.90
FAILURE
HC
HC
PASS
PASS
COST
1.50
1.50
1.50
4.50 TOT.
*************************** Ag RECEIVED FROM OWNER ***************************
TEST NO:C0125
08/24/73 BAR:24.73 DB:71 WB:60
REL.HUM:55.1% NOXCOR:1.001
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
5.76
77.7
619.7
5.92
11.72
COLD STABILIZED
4.07
69.4
652.6
2.88
11.50
HOT TRANSIENT
4.06
43.6
544.6
6.27
14.23
1975 COMPOSITE
4.42
64.0
615.8
4.45
12.20
IDLE KEYMODE
4031
5.44
88
576
340
4.75
LOW CR. KEYMODE
2023
0.32
1019
306
90
0.35
HI. CR. KEYMODE
2466
0.32
4174
340
150
0.35
2500 RPM
45
0.70
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:CO144
08/27/73 BAR:24.71 DB:78 WB:58
REL.HUM:31.3% NOX COR: .910
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.98
3.16
3.50
3.85
79.0
35.8
27.9
42.6
635.3
657.1
547.6
622.2
5.92
2.95
6.03
4.43
11.44
12.31
14.78
12.70
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4070
2553
3087
1.90
0.31
0.28
103
1217
4772
652
437
473
420
150
260
110
1.70
0.35
0.30
0.70
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 071
1972 VOLK SEDA 97
2250LBS
IDLE INSPECTION ONLY
4CYL 1BBL 4 SPEED 041347 MILES
HAS: EMC, EVC, NO PCV
====================
== MAINTENANCE STATUS
asssssssaasassssaaassassss
!=== =
I. CO
I.RPM
TIM DWL
PCV A
.CL CHOKE A.PMP MISF.
NOXC
FRCM OWNER 6.30
+0000
-03 +14
BAD
OK OK NA NO
NA
FROM INSP. 3.30
-0175
-05 +10
BAD
OK OK NA NO
NA
IDLE INSPECTION -
STATION NO. 4
I. HC
2500HC
I. CO
2500CO FAILURE COST
INITIAL INSPECTION
110
85
4.50
4.00 CO 5.00
AFTER I.RPM ADJUST
110
8
4.50
4.00 CO 0.00
AFTER I.MX/TM ADJ1
70
55
2.80
2.00 PASS 1.00
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
70
55
2.80
2.00 PASS
6.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0127
HC CO
COLD TRANSIENT 7.79 68.7
COLD STABILIZED 6.62 86.0
HOT TRANSIENT 5.11 67.8
1975 COMPOSITE 6.44 77.3
IDLE KEYMODE 4860 6.97
LOW CR. KEYMODE 3215 1.60
HI. CR. KEYMODE 2666 1.24
2500 RPM
08/24/73 BAR:24,72 DB:75 WB:59
REL.HUM:40.8% NOX COR: .950
C02
NOX
MPG
LHC
SHC
SCO
290.4
311.2
273.9
296.5
2.60
1.75
2.31
2.08
21.05
19.06
22.45
20.32
71
942
1999
482
410
347
230
165
125
6.70
1.60
1. 20
200
4.60
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0147
08/27/73 BAR:24.64 DB:77 WB:58
REL.HUM:33.4% NOX COR: .917
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.37
4.69
4.56
5.00
63.5
67.6
75.4
68.9
291.0
313.6
253.9
292.3
2.33
2.06
2.12
2.13
21.67
20.49
23.02
21.39
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4108
3541
3069
3.63
1.46
1.14
101
1259
2535
545
476
443
1050
250
190
620
5.40
1.50
1. 10
2.80
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 072
1972 CHEV NOVA 250 3000LBS
6CYL 1BBL AUTOMATIC 012834 MILES
IDLE INSPECTION ONLY
HAS: EMC, EVC, PCV
===========»===>=>=====.=======.== MAINTENANCE STATUS ==============================
I.CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 6.10 -0020 +04 +01 BAD OK OK NA YES NA
FROM INSP. 1.08 -0150 +02 +02 BAD BAD OK NA NO NA
IDLE INSPECTION
STATION NO. 2
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
170
140
100
100
2500HC
100
30
50
50
I. CO
4.20
4.20
1.60
1.60
2500CO
2.00
1.00
1.40
1.40
FAILURE
BOTH
CO
PASS
PASS
COST
0.00
0.00
0.00
9.90
9.90 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:CO126
08/24/73 BAR:24.71 DB:79 WB:61
REL.HUM:37.6% NOX COR: .964
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
3.06
2.59
2.48
2.66
55.8
37.7
32.5
40.1
530.8
521. 1
432.0
498.4
2.82
2.14
2.99
2.52
14.18
15. 13
18.14
15.63
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
4503
1627
3133
6.59
0.21
3.19
78
1274
1304
704
255
335
460
70
160
2500 RPM
*************************
TEST NO:C0148
75
6.20
0.25
3.20
1.30
AS RECEIVED FROM INSPECTION ************************
08/27/73 BAR:24.66 DB:74 WB:56
REL.HUM:34.0% NOX COR: .900
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.22
1.95
2.25
2.51
46.8
12.7
19.1
21.6
524.6
507.9
408.3
483.8
2.94
2.16
2.91
2.53
14.56
16.68
20.00
16.95
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3752
1925
3338
1.25
0.17
2.28
129
1243
1651
646
454
487
510
120
280
85
1. 10
0.20
2.25
0.40
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 073
1971 FORD TORI 351 3500LBS
8CYL 2BBL AUTOMATIC 022051 MILES
TUNE UP EVALUATION
HAS: EMC, EVC, PCV
FROM OWNER
FROM INSP.
I.CO I.RPM
1.80 +0450
1.80 +0450
MAINTENANCE STATUS ==
TIM DWL
+04 +06
+04 +06
PCV
OK
OK
A.CL
OK
OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
STATION NO. 5
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION —
I.HC 2500HC
190 60
190
60
I. CO 2500CO
0.80 0.45
0.80 0.45
FAILURE COST
PASS 5.50
PASS
5.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0123
08/24/73 BAR:24.73 DB:70 WB:55
REL.HUM:40.4% NOX COR: .907
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.37
4.51
3.99
4.55
50.4
47.9
34.9
44.8
555.6
523.0
478.8
517.5
4.07
3.00
4.11
3.53
13.67
14.54
16.30
14.79
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2992
3314
3356
2.06
0.38
0.99
119
1865
2077
490
510
425
290
280
250
100
1.90
0.45
1.05
0.60
************************* as RECEIVED FROM INSPECTION ************************
TEST NO:C0123
08/24/73 BAR:24.73 DB:70 WB:55
REL.HUM:40.4% NOX COR: .907
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.37
4.51
3.99
4.55
50.4
47.9
34.9
44.8
555.6
523.0
478.8
517.5
4.07
3.00
4.11
3.53
13.67
14.54
16.30
14.79
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2992
3314
3356
2.06
0.38
0.99
119
1865
2077
490
510
425
290
280
250
100
1.90
0.45
1.05
0.60
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 074
1965 FORD FAIR 289 3500LBS
8CYL 2BBL AUTOMATIC 073336 MILES
TUNE UP EVALUATION
HAS: NO EMC, NO EVC, PCV
FROM OWNER
FROM INSP.
================3== MAINTENANCE STATUS ==============»=====>=========
I.CO I.RPM
4.20 +0100
4.20 +0100
TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
+09 +02 NA BAD OK NA NO NA
+09 +02 NA BAD OK NA NO NA
STATION NO. 8
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
420
— IDLE INSPECTION —
2500HC
350
420 350
I. CO
4.20
2500CO
2.80
FAILURE COST
PASP 3.50
4.20 2.80
PASS
3.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO.-C0124
08/24/73 BAR:24.73 DB:70 WB:59
REL.HUM:54.5% NOX COR: .986
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
HC
7.92
7.09
5.85
6.92
CO
102.7
91.7
72.8
88.7
C02
456.4
451.5
410.2
441.1
NOX
5.38
4.66
5.43
5.02
MPG
13.85
14.41
16.40
14.79
LHC
SHC
SCO
IDLE KEYMODE
4465
4.50
177
642
405
4.25
LOW CR. KEYMODE
3937
2.67
1567
609
375
2. 70
HI. CR. KEYMODE
3475
2.01
2826
491
275
1.95
2500 RPM
450
3. 10
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0124
08/24/73 BAR:24.73 DB:70 WB:59
REL.HUM:54.5% NOX COR: .986
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.92
7.09
5.85
6.92
102.7
91.7
72.8
88.7
456.4
451.5
410.2
441.1
5.38
4.66
5.43
5.02
13.85
14.41
16.40
14.79
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4465
3937
3475
4.50
2.67
2.01
177
1567
2826
642
609
491
405
375
275
450
4.25
2.70
1.95
3. 10
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 075
1971 FORD PINT 98 2250LBS
4CYL 1BBL 4 SPEED 012609 MILES
IDLE INSPECTION ONLY
HAS: EMC, EVC, PCV
FROM OWNER
FROM INSP.
I. CO
10.70
4.70
»========»=• MAINTENANCE STATUS =========*===============*=====
I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
-0100 +00 +05 OK BAD OK NA NO NA
-0080 +08 +06 OK BAD OK NA NO NA
IDLE INSPECTION
STATION NO. 4
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
950
175
*****
5.50
BOTH
5.00
AFTER I.RPM ADJUST
950
175
*****
5.50
BOTH
1.50
AFTER I.MX/TM ADJ1
500
100
4.00
1.20
BOTH
1.50
AFTER I.MX/TM ADJ2
620
105
4.10
1.00
BOTH
2.00
REPAIRS
6.00
FINAL INSPECTION
325
130
4.00
1.20
PASS
16.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0134
08/27/73 BAR:24.74 DB:70 WB:54
REL.HUM:37.1% NOX COR: .890
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.20
8.36
5.77
7.40
82.8
79.5
61.8
75.3
233.9
248.5
215.3
236.2
1.58
1.41
1.56
1.49
23.03
22.27
26.93
23.57
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
40599
4852
4242
9.95
3.68
4.56
21
552
1336
1624
462
420
****
335
315
315
3.80
4.50
6.50
*************************
AS RECEIVED FROM
INS PECTION ************************
TEST NO:C0160
08/28/73 BAR:24.78 DB:70 WB:58
REL.HUM:50.9% NOX COR: .963
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.98
3.97
3.27
3.99
70.0
52.6
46.0
54.4
237.7
267.1
212.8
245.9
1.39
1.35
1.31
1.35
24.50
24.58
30.15
25.90
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
6632
4092
3924
6.77
2.63
3.70
55
355
1049
1005
555
552
700
250
310
200
4.80
2.60
3.50
2. 30
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 076
1967 BUIC LESA 340 4000LBS
8CYL 4BBL AUTOMATIC 021887 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
============================== MAINTENANCE STATUS ==============================
I. CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FRCM OWNER 5.60 +0180 402 -04 OK OK OK NA NO NA
FROM INSP. 5.60 +0180 +02 -04 OK. OK OK NA NO NA
IDLE INSPECTION
STATION NO. 1
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
340
340
2500HC
250
250
I. CO
5.00
5.00
2500CO
5.30
5.30
FAILURE
PASS
PASS
COST
2.50
2.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0135
08/27/73 BAR:24.74 DB:70 WB:54
REL.HUM:37.1% NOX COR: .890
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
11.36
8.24
7.68
8.74
212.4
220. 1
184.3
208.6
401. 1
401.8
357.0
389.2
0.90
0.43
0.89
0.66
11.55
11.51
13.27
11.96
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
4485
4705
4775
6.35
6.78
9.39
46
270
206
529
610
579
440
520
460
2500 RPM
*************************
TEST N0:C0135
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
400
5.70
6.40
9.00
6.30
AS RECEIVED FROM INSPECTION ************************
08/27/73 BAR:24.74 DB:70 WB:54
REL.HUM:37.1% NOX COR: .890
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
11.36
8.24
7.68
8.74
212.4
220.1
184.3
208.6
401. 1
401. 8
357.0
389.2
0.90
0.43
0.89
0.66
11.55
11.51
13.27
11.96
4485
4705
4775
6.35
6.78
9.39
46
270
206
529
610
579
440
520
460
400
5.70
6.40
9.00
6.30
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 077
1972 CHEV IMPA 400 4500LBS
8CYL 4BBL AUTOMATIC 027848 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, EVC, PCV
:«===========
========
=== MAINTENANCE STATUS
===
========
ssssass;
I. CO
I.RPM
TIM DWL PCV A
.CL
CHOKE
A.PMP
FROM
OWNER 2.50
+0060
+04 +01 OK
OK
OK
OK
FROM
INSP. 2.50
+0060
+04 +01 OK
OK
OK
OK
NO
NO
NOXC
NA
NA
STATION NO. 8
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
120
IDLE INSPECTION
I.HC 2500HC
120 45
45
I. CO 2500CO
2.10 0.25
2.10 0.25
FAILURE COST
PASS 3.50
PASS
3.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0136
08/27/73 BAR:24.73 DB:71 WB:54
REL.HUM:34.6% NOX COR: .884
HC
CO
C02
NOX
MPG
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.65
2.16
2.81
2.86
84.1
52.4
56.3
60.1
672.0
720.8
569.6
668.7
3.10
1.97
3.18
2.54
10.87
10.99
13.35
11.53
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
1829
2521
2041
2.83
0.67
1.28
34
1142
1400
LHC
SHC
SCO
284
90
2.70
339
145
0.55
263
100
1.20
35
0.28
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:CO136
08/27/73 BAR:24.73 DB:71 WB:54
REL.HUM:34.6% NOX COR: .884
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.65
2.16
2.81
2.86
84.1
52.4
56.3
60.1
672.0
720.8
569.6
668.7
3.10
1.97
3.18
2.54
10.87
10.99
13.35
11.53
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
1829
2521
2041
2.83
0.67
1.28
34
1142
1400
284
339
263
90
145
100
35
2.70
0.55
1.20
0.28
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 078
1972 FORD STAW 351 4000LBS
8CYL 2BBL AUTOMATIC 020434 MILES
IDLE INSPECTION ONLY
HAS: EMC, EVC, PCV
======»=====•================= maintenance status ===
I. CO I.RPM TIM DWL PCV A.CL
FROM OWNER 4.20 -0210 +24 +05 OK OK
FROM INSP. 4.20 -0210 +24 405 OK OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
STATION NO. 5
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC 2500HC
170 90
170
90
I.CO 2500CO
3.80 1.80
3.80 1.80
FAILURE COST
PASS 5.50
PASS
5.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST N0:C0137
"08/27/73 BAR:24.73 DB:72 WB:55
REL.HUM:35.5% NOX COR: .894
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.03
5.00
4.47
4.86
87.2
95.7
72.8
87.6
573.7
660.9
564.3
615.9
5.17
4.36
5.79
4.93
12.25
10.77
12.85
11.59
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
3069
3391
3151
4.73
1.75
1.91
89
1861
1871
399
490
402
275
440
330
2500 RPM
190
4.45
1.65
1.90
1.60
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:CO137
08/27/73 BAR:24.73 DB:72 WB:55
REL.HUM:35.5% NOX COR: .894
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.03
5.00
4.47
4.86
87.2
95.7
72.8
87.6
573.7
660.9
564.3
615.9
5.17
4.36
5.79
4.93
12.25
10.77
12.85
11.59
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3069
3391
3151
4.73
1.75
1.91
89
1861
1871
399
490
402
275
440
330
190
4.45
1.65
1.90
1.60
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 079
1971 FORD STAW 400 4500LBS
8CYL 2BBL AUTOMATIC 035284 MILES
IDLE INSPECTION ONLY
HAS: EMC, EVC, PCV
============================== MAINTENANCE STATUS ==============================
I. CO I.RPM TIM DWL PCV A.CL CHOKE A. PMP MISF. NOXC
FRCM OWNER 7.60 -0060 +00 +02 OK OK OK NA NO NA
FROM INSP. 3.06 -0080 +00 -02 OK OK OK NA NO NA
IDLE INSPECTION
STATION NO. 7
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
700
840
6.40
4.40
BOTH
2.50
AFTER I.RPM ADJUST
680
850
6.10
2.30
BOTH
2.50
AFTER I.MX/TM ADJ1
580
800
4.10
4.10
BOTH
2.50
AFTER I.MX/IM ADJ2
0
0
0.00
0.00
BOTH
2.50
REPAIRS
10.50
FINAL INSPECTION
380
250
3.20
1.40
HC
35.00
20.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:COl38
08/27/73 BAR:24.73 DB:72 WB:55
REL.HUM:35.5% NOX COR: .894
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
8.17
120.9
571.4
4.29
11.31
COLD STABILIZED
5.71
95.3
555.0
3.63
12.32
HOT TRANSIENT
5.07
59.4
518.8
5.47
14.18
1975 COMPOSITE
6.05
90.7
548.3
4.28
12.55
IDLE KEYMODE
5423
8.05
34
654
720
8.20
LOW CR. KEYMODE
3102
0.63
1797
422
365
0.65
HI. CR. KEYMODE
2548
0.90
1831
318
205
0.90
2500 RPM
1100
1.10
A************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0176
08/29/73 BAR:24.76 DB:72 WB:58
REL.HUM:45.2% NOX COR: .949
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.39
4.20
4.49
4.95
101.1
61.5
41.8
64.3
621.5
591.4
531.7
581.1
5.78
4.55
6.51
5.35
11.08
12.70
14.56
12.76
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3416
2781
2120
3.19
0.32
0.57
52
2211
1855
660
611
501
360
240
110
250
3.20
0.40
0.58
0.75
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 080
1967 CHEV MALI 283 3500LBS
8CYL 2BBL 3 SPEED 075280 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
============================== MAINTENANCE STATUS ==============================
I. CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 5.60 -0060 -18 400 OK BAD OK NA NO NA
FROM INSP. 4.97 +0025 -06 +02 OK BAD OK NA NO NA
STATION NO. 2
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
950
950
600
600
2500HC
325
325
290
290
I. CO
3.75
3.75
4.75
4.75
2500CO
3.50
3.50
4.00
4.00
FAILURE
BOTH
BOTH
PASS
PASS
COST
5.50
3.30
3.30
12.10 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0139
08/27/73 BAR:24.73 DB:75 WB:56
REL.HUM:31.8% NOX COR: .893
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
12.76
12.01
8.20
11.11
128.6
108.3
90.5
107.6
362.1
367.0
335.0
357.1
2.55
1.52
2.37
1.97
14.73
15.48
17.70
15.87
16863
5664
4706
6.56
4.38
3.14
28
985
1216
1506
799
667
1750
770
615
720
5.60
4.30
3.20
4.00
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0161
08/28/73 BAR:24.78 DB:70 WB:58
REL.HUM:50.9% NOX COR: .963
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
16.03
9.95
8.96
10.95
132.2
110.0
93.9
110.2
371.8
349.4
315.3
344.6
2.33
1.09
1.89
1.57
14. 13
16.08
18. 13
16. 13
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
12729
5533
4623
5.93
4.36
3.01
22
664
989
1264
867
742
800
480
370
370
5.00
4.20
2.80
3.00
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 082
1971 PLYM STAW 383 4000LBS
8CYL 2BBL AUTOMATIC 050843 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, EVC, PCV
==================.==
=========
== MAINTENANCE STATUS ======
I. CO
I.RPM
TIM DWL
PCV
A.CL i
FRCM OWNER 4.70
+0090
-02 +04
OK
OK
FRCM INSP. 1.90
-0010
-02 +03
OK
OK
IDLE INSPECTION
STATION NO. 3
I.HC
2500HC
I. CO
2500CO
INITIAL INSPECTION
490
40
8.00
1.50
AFTER I.RPM ADJUST
220
30
8.00
1.00
AFTER I.MX/TM ADJ1
110
100
1.70
2.80
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
110
100
1.70
2.60
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
FAILURE
BOTH
CO
PASS
PASS
COST
0.00
0.00
0.00
12.00
12.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:CO150
08/28/73 BAR:24.71 DB:69 WB:55
REL.HUM:43.1% NOX COR: .914
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.37
4.62
4.47
4.94
131.0
98.9
101.3
106.3
614.4
633.8
548.9
606.2
3.01
2.42
3.25
2.77
10.60
11.08
12.33
11.29
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
3635
3016
4133
5.11
0. 26
6.53
48
1474
353
483
416
482
370
270
460
2500 RPM
90
4.60
0.30
6.70
0.35
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0191
08/30/73 BAR:24.67 DB:72 WB:55
REL.HUM:35.5% NOX COR: .895
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.00
4.16
4.67
4.89
137.2
80.6
107.7
100.0
589.8
635.1
503.7
589.2
2.52
1.99
2.13
2.14
10.76
11.49
12.95
11.69
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3209
3380
4546
2.15
0.47
8.45
61
1547
171
545
638
738
185
230
315
60
2. 10
1.90
8.60
0.90
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 083
1970 DODG DART 318 3000LBS
8CYL 2BBL AUTOMATIC 016300 MILES
IDLE INSPECTION ONLY
HAS: EMC, NO EVC, PCV
============================== MAINTENANCE STATUS =================
FRCM OWNER
FRCM INSP.
I.CO I.RPM
6.30 +0040
0.78 -0150
TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
-05 +02 OK OK OK NA NO NA
+02 +06 OK OK OK NA NO NA
IDLE INSPECTION
STATION NO.
1
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
220
200
150
150
2500HC
70
70
175
175
I. CO
8.00
7.00
2.80
2.80
2500CO
3.00
3.20
2.40
2.40
FAILURE
CO
CO
PASS
PASS
COST
2.50
0.00
5.00
7.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0151
08/28/73 BAR:24.71 DB:71 WB:54
REL.HUM:34.7% NOX COR: .884
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.16
4.24
4.26
4.44
92.4
87.8
67.7
83.2
498. 1
513.3
440. 4
489.9
2.04
1.40
2.29
1.78
13.50
13.40
15.90
14.04
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
4391
3585
3769
7.16
1.43
2.46
46
608
945
560
517
501
530
390
395
6.60
1.60
2.50
2500 RPM
260
1.40
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO-.C0175
08/29/73 BAR:24.76 DB:75 WB:59
REL.HUM:40.8% NOX COR: .949
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.91
4.16
4.52
4.62
74. 1
46.5
46.4
52. 2
507.3
525. 1
428.0
494.4
2.92
2.12
3.11
2.56
13.86
14.57
17.29
15.07
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3216
3623
3642
1.11
0.79
2.41
63
1198
1248
645
609
556
400
320
285
180
0.90
1.00
2.40
1.00
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 084
1970 PONT GTO 400 4000LBS
8CYL 4BBL AUTOMATIC 042846 MILES
IDLE INSPECTION ONLY
HAS: EMC, NO EVC, PCV
==============
======
=========
« MAINTENANCE
; STATUS
============»=====
223 32233
:===
I. CO
I.RPM
TIM DWL
PCV A
.CL CHOKE A.PMP
MISF.
NOXC
FROM OWNER
2.30
+0240
+03 -01
OK
OK OK NA
YES
NA
FROM INSP.
2.06
+0075
+02 -01
OK
OK OK NA
YES
NA
IDLE INSPECTION -
STATION NO.
9
I.HC
2500HC
I. CO
2500CO FAILURE
COST
INITIAL INSPECTION
600
200
0.80
1.50 HC
0.00
AFTER I.RPM ADJUST
140
80
1.10
1.00 PASS
0.00
AFTER I.MX/TM
AD J1
AFTER I.MX/TM ADJ2
REPAIRS
4.00
FINAL INSPECTION
140
80
1.10
1.00 PASS
***************************
TEST NO:C0149
4i 00 TOT.
AS RECEIVED FROM OWNER ***************************
08/27/73 BAR:24.71 DB:73 WB:55
REL.HUM:33.2% NOX COR: .888
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
6.34
129.8
685.6
2.06
9.79
COLD STABILIZED
4.27
51.2
647.1
2.11
12.02
HOT TRANSIENT
4.33
62.8
607.5
2.45
12.37
1975 COMPOSITE
4.72
70.9
644.2
2.19
11.56
IDLE KEYMODE
3802
2.65
67
607
500
2.40
LOW CR. KEYMODE
3037
0.59
855
474
280
0.60
HI. CR. KEYMODE
4270
2.62
694
645
790
0.70
2500 RPM
160
1.70
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0174
08/29/73 BAR:24.77 DB:73 WB:58
REL.HUM:42.6% NOX COR: .942
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.38
4.23
4.31
4.70
121.5
57.2
69.3
74.0
673.1
638.6
573.5
627.8
2.41
2.15
2.36
2.26
10.07
12.00
12.79
11.74
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3527
2476
4014
2. 27
0.51
1.86
71
733
973
569
401
620
320
150
550
100
2.40
0.55
2.10
1.75
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 085
1968 BUIC RIVI 430 4500LBS
8CYL 4BBL AUTOMATIC 060029 MILES
IDLE INSPECTION ONLY
HAS: EMC, NO EVC, PCV
MAINTENANCE STATUS ==============================
I. CO I.RFM TIM DWL PCV A.CL CHOKE A. PMP MISF. NOXC
FROM OWNER 6.50 -K)090 +05 -10 OK OK OK NA YES NA
FRCM INSP. 3.30 -0075 +06 -08 OK OK OK NA NO NA
IDLE INSPECTION
STATION NO. 5
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
350
380
250
250
2500HC
325
160
160
160
I. CO
8.10
8.10
2.40
2.40
2500CO
3.20
3.00
2.90
2.90
FAILURE
BOTH
BOTH
PASS
PASS
COST
5.50
5.50
0.00
11.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST N0:C0165
08/29/73 BAR:24.76 DB:69 WB:58
REL.HUM:53.9% NOX COR: .971
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
10.00
7.68
7.81
8.20
145.5
155.4
99.7
137.8
525.9
493.9"
471.7
494.5
5.19
3.28
6.16
4.48
11.33
11.68
13.64
12.09
6062
4178
4903
8.63
3.69
2.22
218
994
1936
893
665
806
345
280
315
280
7.10
3.40
2.00
3.60
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST N0:C0190
08/30/73 BAR:24.68 DB:72 WB:56
REL.HUM:38.7% NOX COR: .912
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7. 13
5.62
5.50
5.90
127.1
105.2
71.6
100.5
500.9
498.5
450.7
485.7
4.21
2.62
5.03
3.62
12.31
13.07
15.34
13.45
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4829
4060
3671
3.74
3.00
1.82
74
1403
2474
733
690
619
420
360
240
280
3.40
2.80
1.80
2.79
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 087
1967 OLDS STAW 330 4000LBS
8CYL 2BBL AUTOMATIC 064223 MILES
IDLE INSPECTION ONLY
HAS: EMC, NO EVC, PCV
========== MAINTENANCE, STATUS =======
FROM OWNER
FROM INSP.
I.CO I.RPM
9.20 +0090
9.20 +0090
TIM DWL
-18 -07
-18 -07
PCV
OK
OK
A.CL
BAD
BAD
CHOKE
OK
OK
A.PMP MISF. NOXC
NA NO NA
NA NO NA
STATION NO. 6
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC
230
2500HC
160
230 160
I. CO
4.40
2500CO
3.20
FAILURE COST
PASS 4.50
4.40 3.20
PASS
4.50 TOT.
***************************
AS RECEIVED FROM OWNER
***************************
TEST NO:C0164
08/29/73 BAR
.: 24. 76
DB : 72
WB:57
REL.HUM:
41.9%
NOX COR:
: .930
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
11.98
193.4
496.9
3.04
10.62
COLD STABILIZED
11.69
175.7
496.3
1.88
11.00
HOT TRANSIENT
7.75
133.9
440.2
2.85
13.19
1975 COMPOSITE
10.66
167.8
480.8
2.39
11.45
IDLE KEYMODE
11326
10.53
20
926
565
9.70
LOW CR. KEYMODE
4607
4.43
599
688
300
4.50
HI. CR. KEYMODE
4251
4.49
976
622
245
4.35
2500 RPM
270
4.90
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0164
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
08/29/73 BAR:24.76 DB:72 WB:57
REL.HUM:41.9% NOX COR: .930
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
11.98
11.69
7.75
10.66
193.4
175.7
133.9
167.8
496.9
496.3
440.2
480.8
3.04
1.88
2.85
2.39
10.62
11.00
13.19
11.45
11326
4607
4251
10.53
4.43
4.49
20
599
976
926
688
622
565
300
245
270
9.70
4.50
4.35
4.90
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 088
1967 AMMO STAW 290 4000LBS
8CYL 2BBL AUTOMATIC 072440 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
======,===,======,============ MAINTENANCE STATUS ==============================
I.CO I.RFM TIM
DWL
PCV A.CL CHOKE A.PMP MISF.
FRCM OWNER 9.50
-0100
+00 -01
OK
OK
OK
NA
NO
FRCM INSP. 5.80
+0040
+00 -01
OK
OK
OK
NA
NO
IDLE INSPECTION
STATION NO. 7
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
1000
400
8.20
2.10
BOTH
2.50
AFTER I.RPM ADJUST
950
320
8.00
2.00
BOTH
2.50
AFTER I.MX/TM ADJ1
400
220
1.30
1.30
PASS
2.50
AFTER I.MX/TM ADJ2
400
220
1.30
1.30
PASS
2.50
REPAIRS
FINAL INSPECTION
400
220
1.30
1.30
PASS
NOXC
NA
NA
10.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:CO163
08/29/73 BAR:24.76 DB:71 WB:57
REL.HUM:44.5% NOX COR: .937
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
11.63
10.92
9.02
10.54
129.3
147.5
138.0
141.1
496.2
452.5
431.4
455.8
3.51
2.69
4. 14
3.27
12.10
12.39
13.16
12.53
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
10931
4466
6315
10.52
0.91
10.29
23
2046
149
921
702
849
635
345
540
330
10.00
1.00
9.80
1.80
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0179
08/30/73 BAR:24.67 DB:71 WB:56
REL.HUM:41.2% NOX COR: .919
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
10.46
7.45
6.85
7.91
117.7
113.4
106.4
112.3
507.7
480.1
432.9
472.8
3.87
2.74
3.30
3.13
12.27
13.06
14.32
13.21
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
5403
4406
6311
6.56
0.69
10.22
64
2093
183
831
735
885
610
375
540
130
5.90
0.73
9.60
1. 16
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 090
1970 FORD MAVE 200 2750LBS
6CYL 1BBL AUTOMATIC 022467 MILES
IDLE INSPECTION ONLY
HAS: EMC, NO EVC, PCV
=========a==================3== MAINTENANCE STATUS ===
I.CO I.RPM TIM DWL PCV A.CL
FRCM OWNER 1.50 -0090 -12 +01 OK OK
FROM INSP. 1.50 -0090 -12 +01 OK OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 4
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC 2500HC
85 100
85 100
I.CO 2500CO
2.70 1.80
2.70 1.80
FAILURE COST
PASS 5.00
PASS
5.00 TOT.
***************************
TEST NO:C0166
AS RECEIVED FROM OWNER ***************************
08/29/73 BAR:24.77 DB:72 WB:59
REL.HUM:48.6% NOX COR: .970
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
4.01
59.9
391.8
4.11
17.86
COLD STABILIZED
3.52
41.3
398.0
3.11
18.78
HOT TRANSIENT
3.00
34.1
352.2
4.32
21.45
1975 COMPOSITE
3.48
43.2
384.0
3.66
19.24
IDLE KEYMODE
3130
1.71
145
509
165
1.70
LOW CR. KEYMODE
3846
1.00
1229
639
280
0.90
HI. CR. KEYMODE
3730
2.38
1149
562
220
2.40
2500 RPM
125
1.55
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0166
08/29/73 BAR:24.77 DB:72 WB:59
REL.HUM:48.6% NOX COR: .970
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.01
3.52
3.00
3.48
59.9
41.3
34. 1
43.2
391.8
398.0
352.2
384.0
4.11
3.11
4.32
3.66
17.86
18.78
21.45
19.24
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3130
3846
3730
1.71
1.00
2.38
145
1229
1149
509
639
562
165
280
220
125
1.70
0.90
2.40
1.55
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 091
1973 PONT LEMA 400 4000LBS
8CYL 2BBL AUTOMATIC 006704 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, EVC, PCV
MAINTENANCE STATUS ==============================
I.CO I.RPM TIM DWL PCV A.CL
FRCM OWNER 1.40 +0010 +00 403 OK BAD
FROM INSP. 1.40 +0010 +00 +03 OK BAD
CHOKE A.PMP MISF. NOXC
OK NA NO BAD
OK NA NO BAD
STATION NO. 2
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC
75
75
2500HC
40
40
I. CO
1.20
2500CO
1.00
1.20 1.00
FAILURE COST
PASS 5.50
PASS
5.50 TOT.
***************************
AS RECEIVED FROM OWNER
***************************
TEST NO:C0162
08/29/73 BAR
: 24.76
DB :70
WB:56
REL.HUM:
43.8%
NOX COR
: .924
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
4.06
67.3
724.6
2.27
10.56
COLD STABILIZED
3.19
39.0
701.5
2.42
11.52
HOT TRANSIENT
3.07
31.7
598.3
4.40
13.54
1975 COMPOSITE
3.34
42.9
677.7
2.94
11.79
IDLE KEYMODE
2217
1.46
147
353
145
1.55
LOW CR. KEYMODE
2475
0. 16
2659
507
150
0.25
HI. CR. KEYMODE
2425
0.38
3167
472
130
0.40
2500 RPM
80
1.90
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0162
08/29/73 BAR:24.76 DB:70 WB:56
REL.HUM:43.8% NOX COR: .924
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.06
3.19
3.07
3.34
67.3
39.0
31.7
42.9
724.6
701.5
598.3
677.7
2.27
2.42
4.40
2.94
10.56
11.52
13.54
11.79
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2217
2475
2425
1.46
0.16
0.38
147
2659
3167
353
507
472
145
150
130
80
1.55
0.25
0.40
1.90
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 092
1970 FORD MAVE 200 2750LBS
6CYL 1BBL AUTOMATIC 035000 MILES
IDLE INSPECTION ONLY
HAS: EMC, NO EVC, PCV
========= MAINTENANCE STATUS
FROM OWNER
FROM INSP.
I. CO
4.70
0.27
I.RPM
+0090
+0050
TIM DWL
+00 +05
+03 +05
PCV
OK
OK
A.CL
BAD
BAD
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
— IDLE INSPECTION
STATION NO. 10
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
400
A***
4.00
1.50
BOTH
1.50
AFTER I.RPM ADJUST
500
&***
7.00
0.30
BOTH
1.50
AFTER I.MX/TM ADJ1
500
2000
5.00
0.20
BOTH
1.50
AFTER I.MX/TM ADJ2
520
1200
3.40
0.40
BOTH
1.50
REPAIRS
FINAL INSPECTION
270
1600
2.20
0.40
HC
28.30
6.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:CO156
08/28/73 BAR:24.77 DB:77 WB:59
REL.HUM:36.2% NOX COR: .935
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.63
3.17
2.72
3.35
46.7
50.6
27.5
43.4
442.7
424.2
388.1
418.1
8.35
7.07
8.40
7.71
16.78
17.33
20.24
17.93
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3796
3087
3032
5.16
0. 12
3.03
71
3250
1350
567
526
473
340
290
260
****
4.80
0.15
3.00
1.70
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0201
08/31/73 BAR:24.55 DB:80 WB:57
REL.HUM:25.1% NOX COR: .882
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
3.20
2.62
2.25
2.64
30.1
23.2
15.0
22.4
437.9
421.0
366.1
409.3
7.15
6.14
7.71
6.79
17.98
19.12
22.45
19.67
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3249
3034
2631
0.71
0.94
1.20
149
2276
3082
606
609
523
125
215
175
700
0.30
0.60
0.80
1.00
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 093
1972 PLYM DUST 198 3000LBS
6CYL 1BBL AUTOMATIC 020817 MILES
IDLE INSPECTION ONLY
HAS: EMC, EVC, PCV
MAINTENANCE STATUS ==============================
I.CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 5.10 -0060 +00 -03 OK BAD OK NA NO NA
FROM INSP. 0.90 -0120 -03 -03 OK BAD OK NA NO NA
IDLE INSPECTION
STATION NO. 3
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
420
250
150
150
2500HC
20
100
100
100
I. CO
6.50
5.10
1.00
1.00
2500CO
2.50
0.80
0.50
0.50
FAILURE
BOTH
CO
PASS
PASS
COST
0.00
0.00
0.00
12.00
12.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0183
08/30/73 BAR:24.67 DB:74 WB:56
REL.HUM:34.0% NOX COR: .900
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.59
3.43
2.96
3.96
129.2
63.6
76.3
80.8
341.9
344.6
302.2
332.3
2.67
3.85
3.45
3.49
15.74
19.56
20.64
18.88
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
5575
4257
4945
6.03
3.06
8.41
102
1811
541
794
676
699
440
275
330
140
5.20
2.80
7.90
1.00
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0218
09/04/73 BAR:24.88 DB:73 WB:54
REL.HUM:30.OZ NOX COR: .870
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.07
2.96
2.76
3.14
81.0
19.6
45.2
39.6
367.4
372.0
336.5
361.2
3.89
4.90
4.83
4.67
17.55
21.60
21.39
20.56
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
7051
3677
4374
0.14
0.76
7.42
272
3709
908
1082
460
501
800
190
245
100
0. 14
0.85
7.50
0.35
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 094
1969 BUIC LESA 350 4500LBS
8CYL 4BBL AUTOMATIC 034309 MILES
IDLE INSPECTION ONLY
HAS: EMC, NO EVC, PCV
=============
====.===
========
«— MAINTENANCE STATUS
===
I. CO
I.RPM
TIM DWL PCV A,
.CL
FROM
OWNER
5.60
-0060
+08 -04 OK
OK
FROM
INSP.
2.26
-0100
+02 +02 OK
OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 9
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
160
140
140
2500HC
580
280
280
I. CO 2500CO
3.80 4.10
2.10 3.20
2.10
3.20
FAILURE
BOTH
PASS
PASS
COST
0.00
0.00
4.00
4.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0178
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
08/30/73 BAR:24.67 DB:71 WB:56
REL.HUM:41.2% NOX COR: .919
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
7.98
5.52
5.26
5.96
204.1
136.9
132.5
149.8
470.7
489.9
439.6
471.9
3.29
2.65
3.81
3.11
10.90
12.33
13.40
12.27
5846
4594
4597
6.15
2.85
5.89
59
1265
168
852
774
716
380
355
340
1000
5.70
2.80
6.40
3.90
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0200
08/31/73 BAR:24.53 DB:81 WB:60
REL.HUM:31.0% NOX COR: .932
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
8.69
4.60
4.25
5.36
215.3
119.6
113.3
137.9
449.7
487.8
411.3
458.6
2.60
2.22
3.12
2.55
10.92
12.90
14.78
12.87
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3020
3306
3002
2.40
3.00
2.29
80
1387
2288
479
565
488
250
320
230
300
2.20
2.90
1.80
3.50
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 095
1968 AMMO STAW 290 4000LBS
8CYL 2BBL AUTOMATIC 052932 MILES
IDLE INSPECTION ONLY
HAS: EMC, NO EVC, PCV
=============
II
u
ii
ii
it
ii
ii
=======
=== MAINTENANCE STATUS
===
I. CO
I.RPM
TIM DWL PCV A,
.CL
FRCM
OWNER
8.30
-0050
+11 -03 OK
OK
FRCM
INSP.
2.16
-0025
+11 -02 OK
OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 1
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
200
210
220
220
2500HC
250
230
420
420
I. CO
9.00
8.10
3.10
3.10
2500CO
6.80
5.80
1.40
1.40
FAILURE
CO
CO
PASS
PASS
COST
2.50
0.00
4.00
6.50 TOT.
***************************
TEST NO:C0180
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
AS RECEIVED FROM OWNER ***************************
08/30/73 BAR:24.67 DB:74 WB:56
REL.HUM:34.0% NOX COR: .900
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
10.30
10.68
9.16
10.18
138.7
127.7
113.1
126.0
393.5
377.7
349.8
373.3
2.31
2.45
3.06
2.59
13.83
14.55
16.00
14.76
12579
4186
5278
11.85
1.66
8.37
21
1979
301
1083
728
785
540
410
500
400
8.70
1.60
8.30
2.70
IDLE KEYMODE
LOW CR. KEYMODE'
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0202
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
08/31/73 BAR:24.55 DB:81 WB:57
REL.HUM:23.5% NOX COR: .876
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
8.17
5.78
6.15
6.39
114.9
78.8
83.4
87.6
392.8
396.7
341.7
380.6
2.48
2.54
3. 13
2.69
14.86
16.53
18.09
16.54
3828
3635
4671
2.94
1.87
8.09
167
2202
367
585
572
684
330
380
440
410
2.20
1.70
8. 10
2.20
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 096
1965 PONT CATA 389 4000LBS
8CYL 4BBL AUTOMATIC 076369 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
FROM OWNER
FRCM INSP.
I.CO I.RPM
3.10 -0010
6.00 +0300
¦» MAINTENANCE STATUS =»==
TIM DWL PCV A.CL
400 406 OK BAD
400 -05 OK BAD
CHOKE A.PMP MISF. NOXC
OK NA YES NA
OK NA YES NA
STATION NO. 8
IDLE INSPECTION
I.HC
2500HC
I. CO
250OCO
FAILURE
COST
INITIAL INSPECTION
1310
****
0.80
6.40
BOTH
3.50
AFTER I.RPM ADJUST
1720
****
5.00
5.40
BOTH
2.00
AFTER I.MX/TM ADJ1
1400
****
4.50
6.20
BOTH
2.50
AFTER I.MX/TM ADJ2
600
380
4.40
6.80
BOTH
2.00
REPAIRS
31.55
FINAL INSPECTION
600
380
4.40
6.80
CO
30.00
41.55 TOT.
***************************
TEST NO:C0181
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
AS RECEIVED FROM OWNER ***************************
08/30/73 BAR:24.67 DB:75 WB:56
REL.HUM:31.8% NOX COR: .894
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
36.25
33.74
31.40
33.62
224.8
168.6
198.2
188.6
449.2
420.7
374.2
413.7
1.26
0.96
1.11
1.06
9.71
11.24
11.34
10.91
15430
27069
33148
3.73
6.73
9.18
32
180
110
****
****
****
****
****
****
****
3.30
6.60
9.40
5.80
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0219
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
09/04/73 BAR:24.88 DB:70 WB:54
REL.HUM:37.0% NOX COR: .888
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
17.29
12.78
11.37
13.33
307.2
219.8
243.4
244.7
404.5
417.5
363.0
399.7
0.62
0.55
0. 66
0.60
9.45
11.08
11.40
10.78
11942
4965
5510
6.33
7.49
11.09
24
237
163
857
621
636
720
350
340
580
6.50
7.80
*****
8.90
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 097
1964 PLYM VALI 170 3000LBS
6CYL 1BBL 3 SPEED 026268 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
MAINTENANCE STATUS =======================
I. CO I.RPM TIM DWL PCV A.CL
FROM OWNER 9.40 +0000 +09 -02 OK BAD
FROM INSP. 9.40 +0000 +09 -02 OK BAD
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
STATION NO.
INITIAL INSPECTION
RPM ADJUST
MX/TM ADJ1
MX/TM ADJ2
AFTER I
AFTER I
AFTER I
REPAIRS
FINAL INSPECTION
I.HC
260
2500HC
240
260 240
I. CO
4.60
2500CO
4.80
FAILURE COST
PASS 5.50
4.60 4.80
PASS
5.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0182
08/30/73 BAR:24.67 DB:76 WB:56
REL.HUM:29.8% NOX COR: .887
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
10.46
8.55
6.74
8.45
147.2
136.9
123.7
135.4
301.1
321.9
276.0
304.8
1.88
1.83
1.84
1.84
15.75
15.79
18.12
16.37
28157
5518
5596
9.33
5.23
8.31
21
1282
406
1097
834
832
1080
400
450
550
10.00
4.90
8.40
6.50
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0182
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
08/30/73 BAR:24.67 DB:76 WB:56
REL.HUM:29.8% NOX COR: .887
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
10.46
8.55
6.74
8.45
147.2
136.9
123.7
135.4
301.1
321.9
276.0
304.8
1.88
1.83
1.84
1.84
15.75
15.79
18.12
16.37
28157
5518
5596
9.33
5. 23
8.31
21
1282
406
1097
834
832
1080
400
450
550
10.00
4.90
8.40
6.50
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 098
1972 FORD MAVE 302 3000LBS
8CYL 2BBL AUTOMATIC 026575 MILES
COMBINATION RETROFIT
HAS: EMC, EVC, PCV
============================== MAINTENANCE STATUS ==============================
FROM OWNER
FROM INSP.
I.CO I.RPM
4.15 +0060
3.68 +0140
TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
400 -09 OK OK OK NA NO NA
400 -14 OK OK OK NA NO NA
IDLE INSPECTION
STATION NO.
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
420
220
3.20
2.00
HC
2.50
AFTER I.RPM ADJUST
410
220
4.00
3.00
BOTH
2.50
AFTER I.MX/TM ADJ1
360
"220
2.30
2.30
PASS
2.50
AFTER I.MX/TM ADJ2
0
0
0.00
0.00
NO ANS.
2.50
REPAIRS
FINAL INSPECTION
380
220
2.30
2.30
PASS
k k it it it k k k k k k * A k k k k k k A k k k k k k k
TEST NO:C0192
10.00 TOT.
AS RECEIVED FROM OWNER ***************************
08/31/73 BAR:24.49 DB:74 WB:57
REL.HUM:37.2% NOX COR: .920
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.02
4.55
5.00
4.98
88.2
82.6
61.2
77.8
491.0
525.8
429.8
491.9
2.64
1.32
2.55
1.93
13.73
13.29
16.44
14.14
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
3943
3738
4320
4.84
1.58
2.35
78
836
1979
629
642
730
340
265
340
2500 RPM
90
4.30
1.55
2.30
1.90
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0205
09/04/73 BAR:24.81 DB:70 WB:56
REL.HUM:43.8% NOX COR: .924
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.78
4.33
4.49
4.68
72.8
68.5
50.9
64.5
515.2
536.9
433.2
503.6
3.15
1.67
3.04
2.36
13.75
13.53
16.89
14.37
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4152
3919
4331
4.19
0.90
1.99
81
867
1302
485
383
518
330
235
330
95
3.80
1.00
2.00
1.50
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 099
1971 CHEV BLAZ 350 4000LBS
8CYL 4BBL 4 SPEED 019987 MILES
COMBINATION RETROFIT
HAS: EMC, NO EVC, NO PCV
=====
ii
ii
ii
ii
ii
ii
ii
ii
ii
ii
ii
ii
ii
ii
=========
==¦ MAINTENANCE STATUS
sa:
I. CO
I.RPM
TIM DWL PCV A,
.CL
FRCM
OWNER
4.60
+0020
+00 +04 OK
OK
FROM
INSP.
4.00
-0010
+00 +04 OK
OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 2
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECdION
I.HC
140
165
165
2500HC
25
15
15
I. CO
4.60
3.90
3.90
2500CO
0.60
0.20
0.20
FAILURE
BOTH
PASS
PASS
COST
5.50
3.30
8.80 TOT.
***************************
TEST NO:CA194
AS RECEIVED FROM OWNER ***************************
08/31/73 BAR:24.49 DB:74 WB:57
REL.HUM:37.2% NOX COR: .920
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.17
4.52
4.47
4.64
57.5
52.2
54.4
53.9
587.0
612.6
511.6
579.2
3.05
1.90
2.87
2.41
12.84
12.56
14.57
13.13
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
4078
1804
2532
5.21
0.32
1.08
52
682
1406
640
520
542
195
55
115
2500 RPM
*************************
TEST NO:C0203
40
4.70
0.35
1.05
0.43
AS RECEIVED FROM INSPECTION ************************
09/04/73 BAR:24.77 DB:70 WB:55
REL.HUM:40.4% NOX COR: .906
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
8.53
4.19
3.96
5.03
97.8
46.3
41. 1
55.7
562.6
631.5
512.7
584.1
3.26
2. 11
3. 13
2.63
11.98
12.41
15. 10
12.96
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3509
1699
2421
4.37
0.34
0.84
58
731
1721
248
143
206
140
48
90
30
4.10
0.35
0.70
0.30
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 100
1969 FORD MUST 302 3000LBS
8CYL 2BBL AUTOMATIC 047190 MILES
COMBINATION RETROFIT
HAS: EMC, NO EVC, PCV
============================ MAINTENANCE STATUS =================
FROM OWNER
FRCM INSP.
I.CO I.RPM
6.40 -0060
3.06 +0040
TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
-08 +03 OK OK OK NA NO NA
-08 +04 OK OK OK NA NO NA
IDLE INSPECTION
STATION NO.
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
725
375
300
300
2500HC
225
160
180
180
I. CO
6.70
5.60
3.30
3.30
2500CO
2.20
2.00
2.30
2.30
FAILURE
BOTH
BOTH
PASS
PASS
COST
5.00
1.00
1.00
7.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0196
08/31/73 BAR:24.52 DB:70 WB:57
REL.HUM:47.5% NOX COR: .947
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
8.56
6.01
5.22
6.33
119.1
85.2
53.1
83.4
470.0
469.9
427.6
458.2
3.38
3.27
4.68
3.69
13.01
14.30
16.88
14.62
5419
4380
3931
7.16
0.70
0.75
53
2146
2420
856
811
694
460
400
260
180
6. 60
0.70
0.70
1.60
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* as RECEIVED FROM INSPECTION ************************
TEST NO:C0206
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
09/04/73 BAR:24.85 DB:70 WB:56
REL.HUM:43.8% NOX COR: .923
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
8.06
5.71
4.62
5.90
102.2
68.9
50.2
70.7
464.0
461.5
401.5
445.4
3.92
3.28
4.74
3.82
13.70
15.15
17.99
15.49
5997
4575
3810
3.50
0.63
0.59
92
2309
2424
887
638
483
940
450
270
200
3.30
0.70
0.65
1.50
AUTOMOTIVE TESTING LABORATORIES.INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 101
1969 CHEV STAW 327 4500LBS
8CYL 2BBL AUTOMATIC 068576 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
============================== MAINTENANCE STATUS ==============================
FROM OWNER
FROM INSP.
I. CO
5.11
0.17
I.RPM
-0110
-0050
TIM DWL
-08 +01
+00 +01
PCV
OK
OK
A.CL
BAD
BAD
CHOKE
OK
OK
A.PMP
NA
NA
MISF.
YES
NO
NOXC
NA
NA
IDLE INSPECTION
STATION NO. 10
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
700
420
3.17
2.00
BOTH
1.50
AFTER I.RPM ADJUST
600
430
1.90
1.80
HC
1.50
AFTER I.MX/TM ADJ1
600
360
2.20
1.20
BOTH
1.50
AFTER I.MX/TM ADJ2
560
360
1.40
0.70
HC
1.50
REPAIRS
66.09
FINAL INSPECTION
310
160
1.20
0.80
PASS
72.09 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0177
08/30/73 BAR:24.67 DB:71 WB:56
REL.HUM:41.2% NOX COR: .919
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
43.26
241.0
517.8
2.80
8.
62
COLD STABILIZED
40.57
205.2
463.0
1.87
9.
74
HOT TRANSIENT
34.07
176.4
443.6
3.34
10.
75
1975 COMPOSITE
39.33
204.7
469.1
2.47
9.
73
IDLE KEYMODE
22170
5.62
46
****
****
5.20
LOW CR. KEYMODE
21660
2.81
1087
****
****
2.70
HI. CR. KEYMODE
27127
5.71
442
****
****
5.50
2500 RPM
****
3.10
*************************
AS RECEIVED FROM
INSPECTION
************************
TEST NO:C0217
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
09/04/73 BAR:24.88 DB:74 WB:54
REL.HUM:27.9% NOX COR: .865
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
10.32
5.04
5.76
6.34
117.1
21.8
51.8
50.1
603.3
644.9
515.5
600.3
6.11
6.05
6.25
6.12
10.86
12.81
14.48
12.74
3690
4020
3877
0.24
0.48
1.13
286
3226
3380
480
506
441
285
300
225
140
0.26
0.50
1. 10
0.60
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 102
1964 MERC PARK 390 4500LBS
8CYL 4BBL AUTOMATIC 055285 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
============
=============.==,=== MAINTENANCE STATUS
33=
:====-=--
I. CO I.RPM TIM DWL PCV A,
.CL
CHOKE
A.PMP
MISF.
FROM OWNER
7.00 40040 +00 -03 OK
OK
OK
NA
NO
FROM INSP.
7.00 +0040 +00 -03 OK
OK
OK
NA
NO
NOXC
NA
NA
STATION NO. 6
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC 2500HC
400 500
400 500
I.CO 2500CO
6.50 1.50
6.50 1.50
FAILURE COST
PASS 4.50
PASS
4.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0210
09/04/73 BAR:24.86 DB:76 WB:58
REL.HUM:35.4% NOX COR: .921
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
9.71
8.34
5.84
7.93
108.4
122.2
71.6
105.3
519.0
475.8
430.1
472.2
6.99
5.92.
6.71
6.37
12.37
12.83
15.87
13.44
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
6524
4717
4302
8.66
1.41
1.81
61
2604
2647
699
658
583
540
380
290
230
7.40
1.40
1.85
2.40
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0210
09/04/73 BAR:24.86 DB:76 WB:58
REL.HUM:35.4% NOX COR: .921
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
9.71
8.34
5.84
7.93
108.4
122.2
71.6
105.3
519.0
475.8
430.1
472.2
6.99
5.92
6.71
6.37
12.37
12.83
15.87
13.44
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
6524
4717
4302
8.66
1.41
1.81
61
2604
2647
699
658
583
540
380
290
230
7.40
1.40
1.85
2.40
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 103
1973 FORD MAVE 302 3000LBS
8CYL 2BBL AUTOMATIC 009029 MILES
TUNE UP EVALUATION
HAS: EMC, EVC, PCV
============================== MAINTENANCE STATUS ==============================
I. CO I.RPM TIM DWL PCV A.CL CHOKE A. PMP MISF. NOXC
FROM. OWNER 2.20 +0060 +00 +00 OK OK OK NA NO OK
FROM INSP. 2.20 +0060 +00 +00 OK OK OK NA NO OK
IDLE INSPECTION
STATION NO. 5
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
230
230
2500HC
60
60
I. CO
3.00
25O0CO
2.20
3.00 2.20
FAILURE
PASS
PASS
COST
5.50
5.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0208
09/04/73 BAR:24.86 DB:78 WB:55
REL.HUM:23.2% NOX COR: .857
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.59
4.29
3.65
4.39
104.0
83.2
61.2
81.5
571. 7
567.7
498.8
549.5
1.45
1.26
1.50
1.37
11.83
12.51
14.68
12.88
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
5465
4820
4494
2.39
1.44
1.20
85
670
921
694
659
676
300
235
210
2500 RPM
105
2.60
1.50
1. 15
2.20
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0208
09/04/73 BAR:24.86 DB:78 WB:55
REL.HUM:23.2% NOX COR: .857
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.59
4.29
3.65
4.39
104.0
83.2
61.2
81.5
571.7
567. 7
498.8
549.5
1.45
1.26
1.50
1.37
11.83
12.51
14.68
12.88
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
5465
4820
4494
2.39
1.44
1.20
85
670
921
694
659
676
300
235
210
105
2.60
1.50
1. 15
2. 20
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 104
1968 PLYM BELV 273 3500LBS
8CYL 2BBL AUTOMATIC 058630 MILES
SEA LEVEL RETROFIT
HAS: EMC, NO EVC, PCV
============================= MAINTENANCE STATUS =============
I. CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 9.90 +0001 +02 +02 OK OK OK NA NO NA
FRCM INSP. 3.55 +0025 -K)9 +04 OK OK OK NA NO NA
IDLE INSPECTION
STATION NO. 9
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
460
460
200
200
2500HC
200
200
110
110
I. CO
*****
*****
3.80
3.80
2500CO
5.50
5.50
2.80
2.80
FAILURE
BOTH
BOTH
PASS
PASS
COST
0.00
0.00
0.00
4.50
4.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0204
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
09/04/73 BAR:24.77 DB:71 WB:55
REL.HUM:37.8% NOX COR: .900
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
10.59
8.81
6.55
8.55
203.0
186.7
145.8
178.8
412.3
420.3
369.6
404.5
1.16
1.35
1.86
1.45
11.64
12.01
14.38
12.50
12025
3941
4727
10.42
2.82
8.01
24
991
251
696
469
553
620
315
360
215
*****
2.90
8.10
4.60
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0220
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
09/05/73 BAR:24.94 DB:70 WB:52
REL.HUM:30.4% NOX COR: .857
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
8.13
3.80
4.68
4.95
175.7
102.8
102.8
118.0
444.7
472.2
383.4
441.8
1.20
1.97
1.99
1.82
11.93
13.79
15.91
13.85
4048
3826
4783
3.81
1.84
7.69
99
1788
403
499
480
597
325
263
330
190
3.80
2.00
7.80
3.80
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 106
1964 FORD GALA 289 4500LBS
8CYL 2BBL 3 SPEED 030087 MILES
TUNE UP EVALUATION
HAS: NO EMC, NO EVC, NO PCV
========= MAINTENANCE STATUS
I.CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 8.30 +0040 400 +02 NA OK OK NA NO NA
FRCM INSP. 8.30 +0040 400 +02 NA OK OK NA NO NA
I.HC
250
STATION NO. 4
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
2500HC
160
250 160
I. CO
5.20
2500CO
4.50
5.20 4.50
FAILURE
PASS
PASS
COST
5.00
5.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0207
09/04/73 BAR:24.86 DB:69 WB:52
REL.HUM:32.8% NOX COR: .864
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
14.68
13.30
10.25
12.74
157.1
171.6
113.2
152.4
414.4
400.8
367.9
394.5
1.91
1.34
2.00
1.64
12.58
12.50
15.40
13.21
12290
4005
7435
8.88
3.22
6.13
36
797
531
680
409
690
605
255
560
420
8.80
3.10
6.00
4.90
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0207
09/04/73 BAR:24.86 DB:69 WB:52
REL.HUM:32.8% NOX COR: .864
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
14.68
13.30
10.25
12.74
157. 1
171.6
113.2
152.4
414.4
400.8
367.9
394.5
1.91
1.34
2.00
1.64
12.58
12.50
15.40
13.21
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
12290
4005
7435
8.88
3.22
6.13
36
797
531
680
409
690
605
255
560
420
8.80
3. 10
6.00
4.90
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 107
1965 CHEV CORV 164 2750LBS
6CYL 2BBL 4 SPEED 076078 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
MAINTENANCE STATUS ====
FROM OWNER
FRCM INSP.
I. CO
1.70
4.30
I.RPM
-0075
+0500
TIM DWL
+02 -03
+07 -03
PCV A.CL
NA OK
NA OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
STATION NO.
IDLE INSPECTION
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
1200
600
4.40
4.10
BOTH
2.50
AFTER I.RPM ADJUST
1000
800
5.10
6.10
BOTH
2.50
AFTER I.MX/TM ADJ1
800
800
4.30
6.10
BOTH
2.50
AFTER I.MX/TM ADJ2
800
800
4.20
4.20
BOTH
2.50
REPAIRS
FINAL INSPECTION
800
780
4.20
4.20
PASS
10.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0209
09/04/73 BAR:24.87 DB:72 WB:53
REL.HUM:29.1% NOX COR: .861
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
10.62
8.83
5.85
8.38
93.8
79.8
33.1
69.7
297.9
332.9
155.1
276.2
1.58
1.34
1.77
1.51
18.60
18.32
39.48
21.60
13045
5210
4840
2.45
3.77
4.05
46
822
1229
2088
855
738
****
480
400
400
2.00
3.60
3.80
4.00
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST N0:C0229
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
09/05/73 BAR:24.87 DB:75 WB:56
REL.HUM:31.7% NOX COR: .891
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
10.31
6.44
5.40
6.96
107.7
102.3
84.8
98.6
292.3
339.3
280.4
313.2
1.21
1. 11
1.38
1.21
18.02
17.11
20.67
18.18
5531
4802
4636
4.74
4.99
5.15
54
376
904
500
529
533
360
355
375
345
4.55
4.85
4.90
6.10
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 108
1964 FORD FALC 200 3000LBS
6CYL 1BBL 3 SPEED 087334 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
===================
=========
== MAINTENANCE STATUS
=====:
I. CO
I.RPM
TIM DWL
PCV A
• CL 1
FROM OWNER 3.80
+0400
-05 +00
BAD
OK
FROM INSP. 3.80
+0400
-05 +00
BAD
OK
IDLE INSPECTION -
STATION NO. 10
I.HC
2500HC
I. CO
2500CO
INITIAL INSPECTION
240
260
2.40
4.00
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
240
260
2.40
4.00
CHOKE
OK
OK
A.PMP
NA
NA
MISF.
YES
YES
NOXC
NA
NA
FAILURE COST
PASS 1.50
PASS
1.50 TOT.
A************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0212
09/04/73 BAR:24.90 DB:78 WB:55
REL.HUM:23.2Z NOX COR: .857
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
8.57
8.17
8.16
8.25
103.1
145.6
115.4
128.3
310.7
301.8
274.6
296.1
0.99
0.42
0.67
0.61
17.82
16.00
18.48
17.00
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
5562
5856
5129
4.04
7.43
4.88
46
174
556
610
830
531
520
460
460
2500 RPM
490
4. 10
7.60
5.40
6.20
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0212
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
09/04/73 BAR:24.90 DB:78 WB:55
REL.HUM:23.2% NOX COR: .857
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
8.57
8.17
8.16
8.25
103.1
145.6
115.4
128.3
310.7
301.8
274.6
296.1
0.99
0.42
0.67
0.61
17.82
16.00
18.48
17.00
5562
5856
5129
4.04
7.43
4.88
46
174
556
610
830
531
520
460
460
490
4.10
7.60
5.40
6.20
AUTOMOTIVE TESTING LABORATORIES,INC.
Iy900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 109
1966 AMMO AMER 232 3000LBS
6CYL 1BBL 3 SPEED 064169 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
===========
========
=======
=== MAINTENANCE STATUS
====
I. CO
I. RPM
TIM DWL PCV A,
.CL
FROM
OWNER
7.20
+0040
-05 -01 BAD
OK
FROM
INSP.
7.20
+0040
-05 -01 BAD
OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 10
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
600
2500HC
400
600 400
I.CO 2500C0
5.20 4.80
5.20 4.80
FAILURE COST
PASS 1.50
PASS
1.50 TOT.
*************************** as RECEIVED FROM OWNER ***************************
TEST NO:C0211
09/04/73 BAR:24.86 DB:77 WB:55
REL.HUM:25.0% NOX COR: .863
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
10. 17
7.78
6.98
8.06
104.7
113.9
97.3
107.4
307.0
279.2
250.8
277.1
3.12
1.51
2.10
2.01
17.68
18.45
20.91
18.90
17023
4650
4177
8.49
2.57
2.62
26
1805
2058
1029
706
563
720
340
265
730
8.00
2.45
2.00
9.10
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0211
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
09/04/73 BAR: 24.86 DB:77 WB:55
REL.HUM:25.0% NOX COR: .863
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
10.17
7.78
6.98
8.06
104.7
113.9
97.3
107.4
307.0
279.2
250.8
277.1
3.12
1.51
2.10
2.01
17.68
18.45
20.91
18.90
17023
4650
4177
8.49
2.57
2.62
26
1805
2058
1029
706
563
720
340
265
730
8.00
2.45
2.00
9. 10
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX,, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 110
1969 CHEV CHEV 307 3500LBS
8CYL 2BBL AUTOMATIC 045577 MILES
IDLE INSPECTION ONLY
HAS: EMC, NO EVC, PCV
====,====================,===== MAINTENANCE STATUS
I. CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 2.70 +0100 -01 +00 OK BAD OK NA NO NA
FRCM INSP. 0.90 -0010 402 +00 OK OK OK NA NO NA
IDLE INSPECTION
STATION NO.
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
300
220
2.40
4.80
CO
2.50
AFTER I.RPM ADJUST
280
250
3.20
4.80
CO
2.50
AFTER I.MX/TM ADJ1
180
200
3.40
4.60
CO
2.50
AFTER I.MX/TM ADJ2
300
230
1.50
3.00
PASS
2.50
REPAIRS
FINAL INSPECTION
300
230
1.50
3.00
PASS
10.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0221
09/05/73 BAR:24.94 DB:71 WB:52
REL.HUM:28.2% NOX COR: .851
SCO
HC
CO
CO 2
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
9.11
5.42
5.43
6.20
151.5
85.5
90.8
100.8
431.5
452.9
378.6
427.8
2. 12
2.06
2.13
2.09
12.75
14.73
16.54
14.70
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
4161
4612
4387
3.07
3.92
4.18
90
995
1410
519
612
536
310
350
290
2500 RPM
200
3.00
4.00
4. 10
3.20
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0242
09/06/73 BAR:24.70 DB:77 WB:55
REL.HUM:25.1% NOX COR: .865
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
8.35
5.11
5.50
5.90
143.2
64.5
89.3
87.9
439.9
454.9
398.7
436.2
2.19
2.14
2.39
2.22
12.88
15.56
16.01
15.02
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3505
4566
4261
1.05
3.97
3.96
109
980
1483
410
560
456
340
415
330
300
0.95
3.85
3.90
4.60
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 111
1972 FORD TORI 302 4000LBS
8CYL 2BBL AUTOMATIC 017170 MILES
TUNE UP EVALUATION
HAS: EMC, EVC, PCV
»= MAINTENANCE STATUS ==
FRCM OWNER
FRCM INSP.
I.CO I.RPM
1.00 +0120
1.00 +0120
TIM DWL
-02 -10
-02 -10
PCV A.CL
OK BAD
OK BAD
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
— IDLE INSPECTION
STATION NO. 8
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
85
85
2500HC
90
90
I. CO
0.40
2500C0
0.75
0.40 0.75
FAILURE COST
PASS 3.50
PASS
3.50 TOT.
*************************** as RECEIVED FROM OWNER ***************************
TEST NO:C0232 09/06/73 BAR:24.87 DB:70 WB:54
REL.HUM:37.0% NOX COR: .888
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.12
4.16
4.96
5.00
128.3
55.6
64.4
73.3
558.6
662.9
510.2
598.7
3.30
2.62
3.79
3.09
11.38
11.67
14. 20
12.21
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2866
3707
3675
1.13
1.15
2.05
313
2258
2469
294
414
398
205
300
280
90
1. 10
1.25
2. 10
1.25
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0232
09/06/73 BAR:24.87 DB:70 WB:54
REL.HUM:37.0% NOX COR: .888
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.12
4.16
4.96
5.00
128.3
55.6
64.4
73.3
558.6
662.9
510.2
598.7
3.30
2.62
3.79
3.09
11.38
11.67
14.20
12.21
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2866
3707
3675
1.13
1.15
2.05
313
2258
2469
294
414
398
205
300
280
90
1.10
1.25
2.10
1.25
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 112
1970 FORD MUST 351 3500LBS
8CYL 2BBL AUTOMATIC 051330 MILES
TUNE UP EVALUATION
HAS: EMC, NO EVC, PCV
FROM OWNER
FRCM INSP.
I.CO I.RPM
9.90 +0000
9.90 +0000
MAINTENANCE STATUS
TIM DWL PCV A.CL
-10 -04 OK OK
-10 -04 OK OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
STATION NO. 6
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/IM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC
50
50
2500HC
10
10
I. CO
9.00
2500CO
5.00
9.00 5.00
FAILURE COST
PASS 4.50
PASS
4.50 TOT.
*************************** as RECEIVED FROM OWNER ***************************
TEST NO:C0233
09/06/73 BAR:24.87 DB:70 WB:56
REL.HUM:43.7% NOX COR: .923
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
7.21
66.2
543.6
6.68
13.28
COLD STABILIZED
7.19
93.0
447.5
3.48
14.45
HOT TRANSIENT
5.05
45.4
410.5
5.95
17.89
1975 COMPOSITE
6.60
74.2
457.3
4.84
14.98
IDLE KEYMODE
11204
10. 21
29
710
600
*****
LOW CR. KEYMODE
2951
0.50
2666
338
230
0.60
HI. CR. KEYMODE
2853
0.87
3835
311
205
0.90
2500 RPM
650
0.80
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST N0:C0233
09/06/73 BAR:24.87 DB:70 WB:56
REL.HUM:43.7% NOX COR: .923
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.21
7.19
5.05
6.60
66.2
93.0
45.4
74.2
543.6
447.5
410.5
457.3
6.68
3.48
5.95
4.84
13.28
14.45
17.89
14.98
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
11204
2951
2853
10.21
0.50
0.87
29
2666
3835
710
338
311
600
230
205
650
*****
0.60
0.90
0.80
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 113
1969 CHEV STAW 350 4000LBS
8CYL 4BBL AUTOMATIC 075334 MILES
TUNE UP EVALUATION
HAS: EMC, NO EVC, PCV
3=a=:=ia==s=============a==i===i=o MAINTENANCE STATUS ==========>=»=============3======
I. CO I. RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 10.50 +0190 +00 -01 OK BAD OK OK NO NA
FROM INSP. 5.30 +0030 +00 -01 OK OK OK OK NO NA
STATION NO.
IDLE INSPECTION
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
400
400
200
200
2500HC
125
125
125
125
I. CO
*****
*****
4.80
4.80
2500CO
1.80
1.80
1.60
1.60
FAILURE
CO
CO
PASS
PASS
COST
0.00
0.00
0.00
12.00
12.00 TOT.
*************************** as RECEIVED FROM OWNER ***************************
TEST NO:C0234
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
09/06/73 BAR: 24.89 DB:70 WB:54
REL.HUM:37.0% NOX COR: .888
SCO
HC
CO
CO 2
NOX
MPG
LHC
SHC
7.90
7.85
6.17
7.39
114.6
121.3
68.6
105.3
516.6
484.8
446.9
481.0
4.90
3.37
5.93
4.40
12.34
12.72
15.51
13.30
11627
3857
3033
11.09
1.64
0.31
21
1935
3931
716
447
291
590
315
180
725
*****
1.80
0.38
2.70
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0256
09/07/73 BAR:24.59 DB:76 WB:55
REL.HUM:27.1% NOX COR: .872
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.87
5.78
5.13
6.04
118.3
90.7
55.9
86.8
528.9
502.4
460.6
496.3
4.46
3.24
5.15
4.02
12.04
13.43
15.77
13.66
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4272
3742
3123
5.59
1.85
0.85
68
1704
3091
499
443
307
330
320
190
200
5.30
1.85
0.85
2.80
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 115
1967 CHEV IMPA 283 4000LBS
8CYL 2BBL AUTOMATIC 064860 MILES
TUNE UP EVALUATION
HAS: NO EMC, NO EVC, PCV
FRCM OWNER
FRCM INSP.
I.CO I.RPM
3.45 +0020
3.45 +0020
TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
+00 +06 OK BAD OK NA NO NA
+00+06 OK BAD OK NA NO NA
IDLE INSPECTION
STATION NO. 2
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
380
2500HC
550
380 550
I. CO 2500CO
2.60 5.80
2.60 5.80
FAILURE
PASS
PASS
COST
5.50
5.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO.:C0236
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
*************************
TEST NO:CQ236
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
09/06/73 BAR:24.89 DB:76 WB:57
REL.HUM:32.5% NOX COR: .902
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
13.28
13.48
11.24
12.82
176.1
178.3
154.2
171.2
452.8
438.1
416.8
435.2
2.32
1.21
2.37
1.77
11.54
11.70
12.82
11.96
8665
6758
8687
3.75
3.50
9.60
224
1268
245
1488
1095 ..
1161
1090
790
800
180
3.60
3.30
9. 20
5.00
AS RECEIVED FROM INSPECTION ************************
09/06/73 BAR:24.89 DB:76 WB:57
REL.HUM:32.5% NOX COR: .902
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
13.28
13.48
11.24
12.82
176.1
178.3
154.2
171.2
452.8
438.1
416.8
435.2
2.32
1.21
2.37
1.77
11.54
11.70
12.82
11.96
8665
6758
8687
3.75
3.50
9.60
224
1268
245
1488
1095
1161
1090
790
800
180
3.60
3.30
9.20
5.00
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 116
1973 CHEV VEGA 140 2500LBS
4CYL 2BBL 3 SPEED 009706 MILES
IDLE INSPECTION ONLY
HAS: EMC, EVC, PCV
MAINTENANCE STATUS
I. CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 8.80 -0100 +04 -01 OK BAD OK NA NO OK
FRCM INSP. 2.60 -0110 402 +00 BAD BAD OK NA NO OK
STATION NO.
IDLE INSPECTION
I.HC
2500HC
I. CO
250OCO
FAILURE
COST
INITIAL INSPECTION
220
180
3.20
2.40
BOTH
2.50
AFTER I.RPM ADJUST
300
200
2.20
3.10
NO ANS.
2.50
AFTER I.MX/TM ADJ1
200
220
1.00
2.10
NO ANS.
2.50
AFTER I.MX/TM ADJ2
0
0
0.00
0.00
NO ANS.
2.50
REPAIRS
FINAL INSPECTION
200
220
1.10
2.10
PASS
10.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0246
09/07/73 BAR:24.76 DB:72 WB:53
REL.HUM:29.2% NOX COR: .862
HC
CO
C02
NOX
MPG
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.98
5.20
3.90
5.00
100.2
85.3
66.9
83.3
270.5
271.6
221.2
257.4
1.56
0.88
1.41
1.17
19.93
21. 10
26.29
22.04
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
20309
3128
3218
8.96
2.80
4.95
20
555
784
LHC
SHC
SCO
1036
710
8.90
319
165
2.70
358
190
4.50
110
3.90
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0278
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
09/10/73 BAR:24.86 DB:73 WB:64
REL.HUM:63.3% NOX COR:1.089
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
9.11
5.85
5.08
6.32
105.5
87.7
73.7
87.5
256. 1
266.5
242.7
257.7
1.31
0.87
1.80
1.22
19.76
21.06
23.78
21.45
4505
3238
3495
2.95
2.31
5.65
49
436
506
556
400
454
340
150
205
120
2.75
2.30
5.00
3.50
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 117
1970 OLDS CUTL 350 4000LBS
8CYL 2BBL AUTOMATIC 05372 7 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
MAINTENANCE STATUS
I.CO I.RPM TIM DWL PCV A.CL
FRCM OWNER 5.20 +0000 -04 +14 BAD BAD
FRCM INSP. 0.21 +0025 +00 -01 BAD OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 4
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
260
150
150
2500HC
95
85
85
I. CO
6.40
0.60
0.60
2500CO
3.60
3.40
3.40
FAILURE
BOTH
PASS
PASS
COST
5.00
2.00
7.00 TOT.
k k * k * k k * * k k k k k * k k k k k k * k k k k k
AS RECEIVED FROM
[ OWNER
&*&****£&*kkkkkkkkkkkkkkkkk
TEST NO:C0247
09/07/73 BAR
:24.74
DB : 71
WB: 55
REL.HUM:
37.9%
NOX COR:
.900
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
7.44
145.2
541.2
2.73
11.23
COLD STABILIZED
5.23
123.1
518.3
1.57
12.23
HOT TRANSIENT
4.55
103.5
458.3
2.37
14.02
1975 COMPOSITE
5.51
122.3
506.5
2.04
12.44
IDLE KEYMODE
3876
5.56
71
459
270
5.00
LOW CR. KEYMODE
3898
3.22
846
457
260
3.10
HI. CR. KEYMODE
3623
3.91
1168
385
205
3.70
2500 RPM
115
4. 10
kkkkkkkkkkkkkkkkkkkkkkkkk
TEST NO-.C0277
AS RECEIVED FROM INSPECTION ************************
09/10/73 BAR:24.88 DB:80 WB:66
REL.HUM:49.9% NOX COR:1.086
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
8.14
5.09
8.18
6.59
139.2
69.7
94.7
91.2
577.8
595.1
507.5
567.2
2.33
1.74
2.53
2.08
10.83
12.35
13.05
12.18
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3094
3891
3681
0. 24
2.89
3.33
92
650
1120
555
725
727
175
265
215
140
0.25
3. 10
3.30
3.20
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 118
1967 PONT CATA 400 4000LBS
8CYL 2BBL AUTOMATIC 071128 MILES
IDLE INSPECTION ONLY
HAS: EMC, NO EVC, PCV
FROM OWNER
FRCM INSP.
i=======»========= MAINTENANCE STATUS ===
I. CO I.RPM TIM DWL PCV A.CL
0.39 +0000 -04 +03 OK OK
0.39 +0000 -04 +03 OK OK
CHOKE A.PMP MISF. NOXC
OK NA YES NA
OK NA YES NA
STATION NO. 10
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC
500
2500HC
200
500 200
I. CO
0.20
2500CO
2.40
FAILURE COST
PASS 1.50
0.20 2.40
PASS
1.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0248
09/07/73 BAR:24.74 DB:72 WB:56
REL.HUM:38.6% NOX COR: .912
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
HC
5.75
4.59
4.47
4.80
CO
100.7
58.4
79.5
73.1
C02
546.6
542.1
450.7
517.7
NOX
3.32
2.82
3.17
3.02
MPG
12.32
13.73
15.10
13.75
LHC
SHC
SCO
IDLE KEYMODE
3828
0.50
163
411
240
0.50
LOW CR. KEYMODE
3517
2.52
1371
377
220
2.90
HI. CR. KEYMODE
3113
2.94
1727
309
170
3.00
2500 RPM
135
3.90
************************* AS RECEIVED FROM INSPECTION ************************
TEST N0:C0248
09/07/73 BAR:24.74 DB:72 WB:56
REL.HUM:38.6% NOX COR: .912
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.75
4.59
4.47
4.80
100.7
58.4
79.5
73.1
546.6
542.1
450.7
517.7
3.32
2.82
3.17
3.02
12.32
13.73
15.10
13.75
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3828
3517
3113
0.50
2.52
2.94
163
1371
1727
411
377
309
240
220
170
135
0.50
2.90
3.00
3.90
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 119
1971 PONT LEMA 350 3500LBS
8CYL 2BBL AUTOMATIC 031776 MILES
IDLE INSPECTION ONLY
HAS: EMC, NO EVC, PCV
MAINTENANCE STATUS
I. CO I.RFM TIM DWL PCV A.CL
FROM OWNER 2.45 -0010 +00 +00 OK BAD
FROM INSP. 2.45 -0010 +00 +00 OK BAD
CHOKE A.PMP MISF. NOXC
OK NA YES NA
OK NA YES NA
STATION NO.
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC
290
290
2500HC
55
55
I. CO
1.60
2500CO
1.40
FAILURE COST
PASS 5.50
1.60 1.40
PASS
5.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST N0.:'C0249
09/07/73 BAR:24.72 DB:76 WB:59
REL.HUM:38.5% NOX COR: .943
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
6.49
119.9
568.5
2.97
11.46
COLD STABILIZED
4.36
47.7
570. 7
3.03
13.51
HOT TRANSIENT
3.60
39. 1
492.1
4. 10
15.76
1975 COMPOSITE
4.59
60.4
548.4
3.32
13.54
IDLE KEYMODE
4107
2.75
175
553
335
2.50
LOW CR. KEYMODE
3395
1.23
1593
355
190
1.10
HI. CR. KEYMODE
2837
0.95
2286
258
130
0.90
2500 RPM
60
1.90
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0249
09/07/73 BAR:24.72 DB:76 WB:59
REL.HUM:38.5% NOX COR: .943
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.49
4.36
3.60
4.59
119.9
47.7
39.1
60.4
568.5
570.7
492. 1
548.4
2.97
3.03
4.10
3.32
11.46
13.51
15.76
13.54
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4107
3395
2837
2.75
1.23
0.95
175
1593
2286
553
355
258
335
190
130
60
2.50
1.10
0.90
1.90
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 120
1967 DODG CORO 318 3500LBS
8CYL 2BBL AUTOMATIC 044942 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
FRCM OWNER
FROM INSP.
I. CO I.RM
3.20 +0280
3.40 +0020
== MAINTENANCE STATUS =¦==
TIM DWL PCV A.CL
+00 -01 OK OK
+00 +00 OK OK
CHOKE A.PMP MISF. NOXC
OK OK NO NA
OK OK NO NA
— IDLE INSPECTION
STATION NO. 3
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
400
400
400
400
2500HC
850
870
200
200
I. CO
1.00
1.00
2.00
2.00
2500CO
1.00
1.00
3.00
3.00
FAILURE
HC
HC
PASS
PASS
COST
0.00
0.00
0.00
12.00
12.00 TOT.
***************************
AS I
DECEIVED FROM OWNER
***************************
TEST NO:C0245
09/07/73 BAR
:24.76
DB :71
WB: 53
REL.HUM:
31.5%
NOX COR:
.868
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
8.56
131.1
431.5
2.67
13.40
COLD STABILIZED
6.21
101.9
443.2
2.15
14.29
HOT TRANSIENT
5.15
87.0
399.8
2.83
16.11
1975 COMPOSITE
6.41
103.9
428.7
2.45
14.55
IDLE KEYMODE
4252
3.49
121
512
350
3.40
LOW CR. KEYMODE
4684
5.55
605
571
365
5.30
HI. CR. KEYMODE
4126
4.85
904
442
269
4.70
2500 RPM
220
3.30
************************* XS RECEIVED FROM INSPECTION ************************
TEST N0:C0279
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
09/10/73 BAR:24.83 DB:70 WB:60
REL.HUM:58.2% NOX COR:1.007
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
14.00
10.54
8.17
10.61
180.9
154.2
116.0
149.2
442.4
405.1
382.7
406.7
2.07
1.43
2.25
1.79
11.55
13.08
15.07
13.20
5119
4643
4492
3.69
3.09
5. 20
75
1235
714
660
615
539
470
410
330
340
3.65
3.00
4.80
4.20
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 121
1967 VOLK SEDA 91 2000LBS
4CYL 1BBL 4 SPEED 048582 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, NO PCV
============================== MAINTENANCE STATUS ==============================
I. CO I.RPM TIM DWL PCV A.CL CHOKE A. PMP MISF. NOXC
FROM OWNER 8.70 -0150 +00 -09 NA OK OK NA NO NA
FRCM INSP. 4.80 +0050 +00 -10 NA OK OK NA NO NA
IDLE INSPECTION
STATION NO. 4
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
1300
2000
400
400
2500HC
200
200
195
195
I. CO
7.80
7.20
4. 20
2500CO
5.50
5.70
4.10
4.20 4.10
FAILURE
BOTH
BOTH
PASS
PASS
COST
5.00
1.00
1.00
7.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0266
09/10/73 BAR:24.84 DB:70 WB:60
REL.HUM:58.2% NOX COR:1.007
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
7.74
9.95
5.93
8.37
103.9
105.8
82.7
99.0
240.6
240.1
2L3.8
232.9
2.40
1.74
2.13
1.99
20.79
20.34
24.57
21.47
34614
4850
3999
8.41
5.29
4.54
21
1126
1840
****
599
488
1790
320
235
260
9.40
5.00
4.20
6.30
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0294
09/11/73 BAR:24.65 DB:75 WB:60
REL.HUM:44.0% NOX COR: .972
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.17
6.41
4.80
5.91
94.2
88.7
75.6
86.2
241.9
245.4
220.8
237.8
2.45
1.86
2.20
2.08
21.75
21.98
25. 10
22.72
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
7650
4501
3949
5.61
5.16
4.09
54
1280
1955
(
698
512
461
400
280
220
305
4.90
4.80
3.70
4.20
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 122
1967 PONT FIRE 326 3500LBS
8CYL 2BBL 3 SPEED 042146 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
FROM OWNER
FROM INSP.
:aa=iaa====33=33ao MAINTENANCE STATUS ===
I. CO I.RPM TIM DWL PCV A.CL
5.90 -0110 400 -02 OK OK
5.40 +0120 +00 +03 OK OK
:as3S3n3sasss3sas3aaasssss
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
STATION NO. 1
IDLE INSPECTION
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
1200
300
6.40
4.20
BOTH
2.50
AFTER I.RPM ADJUST
1100
300
5.00
2.20
HC
0.00
AFTER I.MX/TM ADJ1
850
350
5.20
3.10
HC
0.00
AFTER I.MX/TM ADJ2
800
430
5.40
4.80
PASS
0.00
REPAIRS
25.49
FINAL INSPECTION
800
430
5.40
4.80
PASS
27.99 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0267 09/10/73 BAR:24.84 DB:70 WB:61
REL.HUM:62.0% NOX COR:1.032
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
9.91
11.88
9.48
10.80
88.4
138.8
91.9
115.2
426.7
365.1
336.8
370.1
4.12
1.85
3.36
2.74
14.92
14.34
17.42
15.22
19722
4720
4183
7.32
2.55
2.31
26
1924
3119
1845
636
566
240
355
305
420
6.80
2.70
2.40
5.70
TEST NO:C0291
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
09/11/73 BAR:24.72 DB:74 WB:62
REL.HUM:53.2% NOX COR:1.027
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
14.09
12.81
8.76
11.95
115.4
150.8
99.0
129.0
396.2
358.4
352.9
364.8
3.14
1.35
3.52
2.33
14.31
14.00
16.61
14.72
18165
4409
4122
6.53
2.49
2.18
38
1756
2896
1241
537
506
740
290
255
330
5.40
2.30
2.00
4.40
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 123
1964 CHEV IMP 283 4000LBS
8CYL 2BBL AUTOMATIC 085172 MILES
TUNE UP EVALUATION
HAS: NO EMC, NO EVC, PCV
FRCM OWNER
FRCM INSP.
I.CO I.RPM
7.40 +0100
7.40 +0100
MAINTENANCE STATUS ==========================
TIM DWL PCV A.CL
-01 +00 OK OK
-01 +00 OK OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 8
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
420
2500HC
420
420 420
I. CO
1.80
2500CO
5.00
FAILURE COST
PASS 3.50
1.80 5.00
PASS
3.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0250
09/07/73 BAR:24.72 DB:76 WB:60
REL.HUM:41.5% NOX COR: .964
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
11.45
8.91
8.07
9.21
187.6
154.0
152.8
160.7
403.3
388.6
346. 1
379.9
1.63
1.04
1.44
1.27
12.13
13.52
14.56
13.47
8637
5442
4994
8.36
6.48
5.89
44
469
924
922
710
586
615
450
360
550
7.80
6.00
5.40
5.80
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0250
09/07/73 BAR:24.72 DB:76 WB:60
REL.HUM:41.5% NOX COR: .964
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
11.45
8.91
8.07
9.21
187.6
154.0
152.8
160.7
403.3
388.6
346.1
379.9
1.63
1.04
1.44
1.27
12.13
13.52
14.56
13.47
8637
5442
4994
8.36
6.48
5.89
44
469
924
922
710
586
615
450
360
550
7.80
6.00
5.40
5.80
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 124
1973 VOLK BUS 102 3000LBS
4CYL 2BBL 4 SPEED 003006 MILES
IDLE INSPECTION ONLY
HAS: EMC, EVC, PCV
zs========3=3=====3M3a3Ma3a3 MAINTENANCE STATUS =============================
I. CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FRCM OWNER 2.10 -0260 +14 -05 NA OK OK NA YES NA
FRCM INSP. 2.10 -0230 +15 404 NA OK OK NA NO NA
IDLE INSPECTION
STATION NO. 7
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
380
360
200
200
2500HC
200
180
120
120
I. CO
3.00
3.00
1.20
1.20
2500CO
1.20
1.20
1.20
1.20
FAILURE
HC
PASS
PASS
PASS
COST
2.50
2.50
2.50
7.50 TOT.
***************************
AS RECEIVED FROM
: OWNER
***************************
TEST NO:C0280
09/11/73 BAR:
24.79
DB : 70
WB:61
REL.HUM:62.0%
NOX COR:
1.033
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
4.83
83.0
404.6
3.88
16.18
COLD STABILIZED
2.86
44.9
472.2
2.98
16.14
HOT TRANSIENT
3.04
53.7
367.4
3.84
19.30
1975 COMPOSITE
3.32
55.3
429.0
3.41
16.92
IDLE KEYMODE
1620
3.19
53
227
80
2.50
LOW CR. KEYMODE
1965
0.74
1285
284
120
0.60
HI. CR. KEYMODE
3855
7.13
971
464
250
5.50
2500 RPM
45
0.75
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0308
09/12/73 BAR:24.65 DB:79 WB:60
REL.HUM:34.9% NOX COR: .944
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.47
2.81
4.17
3.53
61.3
49.7
67.4
57.0
393.2
438.0
339.3
401.2
3.90
2.27
2.75
2.74
17.68
16.97
19.43
17.74
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2726
2705
3013
3.04
1.67
5.04
54
1242
1074
555
594
553
80
100
no
35
2.20
1.20
4.00
1.60
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 125
1971 PONT CATA 400 4500LBS
8CYL 2BBL AUTOMATIC 029602 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
============================== MAINTENANCE STATUS —
FROM OWNER
FROM INSP.
I.CO I.RPM
1.30 +0040
1.30 +0040
TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
+04 +00 OK OK OK NA NO NA
+04 +00 OK OK OK NA NO NA
IDLE INSPECTION
STATION NO. 9
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
120
120
2500HC
50
50
I. CO
1.40
1.40
2500CO
1. 10
1.10
FAILURE
PASS
PASS
COST
0.00
4.00
4.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0281
09/11/73 BAR:24.79 DB:71 WB:62
REL.HUM:62.4% NOX COR:1.051
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.03
4.78
4.77
5.04
101.0
51.5
46.0
60.3
714.3
689.1
597.7
669.0
5.82
4.34
7.34
5.48
9.98
11.34
13.00
11.42
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2836
2771
2440
1.51
0.67
0.81
152
2093
2749
313
305
259
190
170
125
280
1.50
0. 70
0.85
1.60
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0281
09/11/73 BAR
REL.HUM:
:24.79
62.4%
DB : 71
NOX COR:
WB: 62
1.051
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.03
4.78
4.77
5.04
101.0
51.5
46.0
60.3
714.3
689.1
597.7
669.0
5.82
4.34
7.34
5.48
9.98
11.34
13.00
11.42
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2836
2771
2440
1.51
0.67
0.81
152
2093
2749
313
305
259
190
170
125
280
1.50
0.70
0.85
1.60
AUTOMOTIVE
TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 126
1966 CHEV IMPA 327 4000LBS
8CYL 4BBL AUTOMATIC 033735 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, EVC, PCV
FRCM OWNER
FRCM INSP.
================= MAINTENANCE STATUS
I. CO I.RPM
8.20 +0045
3.50 +0000
TIM DWL PCV A.CL
-02 +03 OK OK
-02 +01 OK OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 2
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
740
680
750
750
2500HC
300
320
350
350
I. CO
9.25
8.40
3.00
3.00
2500CO
4.60
4.60
3.80
3.80
FAILURE
BOTH
BOTH
PASS
PASS
COST
5.50
3.30
3.30
12.10 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0282
09/11/73 BAR:24.79 DB:69 WB:59
REL.HUM:57.7% NOX COR: .993
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
10.39
9.29
7.56
9.04
145.9
158.0
121.7
145.4
483.3
420.8
384.3
423.8
3.87
2.09
2.99
2.71
11.95
12.75
14.86
13.09
7578
4619
3854
9.00
3.67
2.48
44
1268
2268
871
613
485
680
420
280
325
8.80
3.50
2.50
5.00
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0306
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
09/12/73 BAR:24.65 DB:79 WB:60
REL.HUM:34.9% NOX COR: .944
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
9.78
7.36
6.26
7.56
142.9
118.9
105.7
120.3
444.3
414.3
379.8
411.0
3.03
1.98
2.87
2.44
12.72
14.26
15.74
14.28
6228
4804
4048
4.03
4.27
2.79
63
1106
1977
919
750
625
520
340
245
320
3.30
3.70
2.60
6. 20
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 127
1966 DODG CORO 318 3500LBS
8CYL 2BBL AUTOMATIC 048219 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
============================== MAINTENANCE STATUS ==============================
I. CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FRCM OWNER 4.30 -0100 +05 +00 OK BAD OK NA NO NA
FRCM INSP. 0.20 +0120 +05 +05 OK BAD OK NA NO NA
IDLE INSPECTION —
STATION NO. 3
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
350
340
350
350
2500HC
250
250
250
250
I. CO
5.00
4.90
2.50
2.50
2500CO
8.50
8.25
5.75
5.75
FAILURE
CO
NO ANS.
PASS
PASS
COST
0.00
0.00
0.00
12.00
12.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0283
09/11/73 BAR:24.79 DB:72 WB:62
REL.HUM:59.2% NOX COR:1.042
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
14.31
6.77
5.00
7.86
210.6
81.5
59.0
102.3
386.4
437.4
398.0
415.8
1.82
5.12
5.70
4.59
11.68
15. 18
17.58
14.81
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
5777
4765
4219
4.79
0.80
2.39
126
3173
2137
720
634
507
615
350
390
240
4.40
0.70
2.30
1.40
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO-.C0309
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
09/12/73 BAR:24.65 DB:77 WB:60
REL.HUM:39.2% NOX COR: .958
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
12.44
4.15
4.01
5.85
174.3
37.2
35.6
65.4
363.0
430.5
392.5
405.8
1.13
2.59
3.02
2.40
13.17
17.73
19.31
16.90
3677
3659
3517
0.25
1.87
2.40
215
1387
1670
727
682
644
265
250
200
115
0.25
2.00
2. 20
1.65
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 128
1966 MERC MONT 390 4000LBS
8CYL 2BBL AUTOMATIC 108053 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
=== MAINTENANCE STATUS ====
FRCM OWNER
FRCM INSP.
I.CO I.RPM
6.50 +0000
6.50 -0040
TIM
+02
401
DWL
-11
-11
PCV
OK
OK
A.CL
BAD
BAD
CHOKE
OK
OK
A.PMP
NA
NA
MISF.
NO
NO
NOXC
NA
NA
IDLE INSPECTION
STATION NO.
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
370
****
4.40
7.00
BOTH
4.50
AFTER I.RPM ADJUST
370
****
4.40
7.00
BOTH
1.50
AFTER I.MX/TM ADJ1
300
1600
5.00
6.00
HC
0.00
AFTER I.MX/TM ADJ2
300
1600
5.00
6.00
HC
3.00
REPAIRS
9.00
FINAL INSPECTION
300
1600
5.00
6.00
HC
18.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0284
09/11/73 BAR:24.77 DB:71 WB:61
REL.HUM:58.7% NOX COR:1.025
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
16.07
21.08
14.24
18.14
255.9
296.5
236.8
271.5
373.4
334.2
302.3
333.6
0.63
0.27
0.53
0.42
10.78
10.27
12.38
10.90
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
9112
7077
6235
8.33
9.33
8.30
35
141
350
1313
1079
915
720
660
520
****
6.70
8.60
7.80
7.70
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0307
09/12/73 BAR:24.65 DB:78 WB:61
REL.HUM:39.9% NOX COR: .973
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
21.92
23.92
17.85
21.82
323.7
383.5
291.5
345.5
406.9
374.5
339.6
371.6
0.40
0.22
0.37
0.30
9.04
8.46
10.43
9.06
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
7862
5460
5163
9.15
10. 11
9.42
33
89
151
941
767
761
345
315
300
6.20
8.90
8.30
8.00
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 129
1965 CHEV BISC 283 3500LBS
8CYL 2BBL AUTOMATIC 073598 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
============================== MAINTENANCE STATUS ==============================
FRCM OWNER
FROM INSP.
I.CO I.RPM
8.70 +0050
5.60 +0000
TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
-14 +00 NA BAD OK NA NO NA
+00 +02 NA BAD OK NA NO NA
IDLE INSPECTION
STATION NO. 8
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
1100
400
8.40
4.50
BOTH
3.50
AFTER I.RPM ADJUST
1000
420
8.00
4.20
BOTH
2.00
AFTER I.MX/TM ADJ1
1040
400
8.20
5.40
BOTH
2.50
AFTER I.MX/TM ADJ2
760
460
4.80
3.60
PASS
2.50
REPAIRS
FINAL INSPECTION
760
460
4.80
3.60
PASS
***************************
TEST N0:C0295
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
10.50 TOT.
AS RECEIVED FROM OWNER ***************************
09/12/73 BAR:24.69 DB:71 WB:60
REL.HUM.-55.1% NOX COR: 1.002
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
10.32
8.96
7. 11
8.73
160.7
164.3
136.5
155.8
394.3
366.4
341.0
365.2
2.50
1.31
1.96
1.74
13. 11
13.64
15.41
13.97
13746
5330
4515
9.41
5.69
4.47
26
616
1207
617
654
546
800
455
315
550
9.20
5.20
4.20
4.40
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST N0:C0324
09/13/73 BAR:24.63 DB:78 WB:56
REL.HUM:26.0% NOX COR: .876
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
8.27
6.72
5.33
6.66
144.2
133.6
125.4
133.6
394.0
377.0
339.7
370.2
1.42
0.77
1.27
1.04
13.77
14.64
16.09
14.82
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
6862
4167
3802
5.99
5.06
4.39
50
491
852
773
689
629
490
355
280
390
5.70
4.80
4.20
5.70
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 130
1965 FORD MUST 200 2750LBS
6CYL 1BBL 3 SPEED 092515 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
FROM OWNER
FRCM INSP.
I.CO I.RPM
3.50 +0020
3.50 +0020
*= MAINTENANCE STATUS ===========
TIM DWL PCV A.CL CHOKE
-02 -07 OK. OK OK
-02 -07 OK OK OK
A.PMP MISF. NOXC
NA YES NA
NA YES NA
IDLE INSPECTION
STATION NO. 1
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
600
2500HC
250
600 250
I. CO
4.20
2500CO
4.80
4.20 4.80
FAILURE
PASS
PASS
COST
2.50
2.50 TOT.
***************************
TEST NO:C0297
AS RECEIVED FROM OWNER ***************************
09/12/73 BAR:24.68 DB:71 WB:60
REL.HUM:55.1% NOXCOR:1.002
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
9.70
8.66
5.60
8.03
67.8
77.9
48.4
67.6
309.2
295.0
272.2
291.6
3.67
2.03
3.44
2.77
19.94
20.02
24.33
21.04
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
5810
4998
4775
3.97
4.71
5.42
61
529
922
544
562
561
450
355
340
3.
4.
80
50
2500 RPM
*************************
TEST NO:C0297
240
5.00
3.50
AS RECEIVED FROM INSPECTION ************************
09/12/73 BAR:24.68 DB:71 WB:60
REL.HUM:55.1% NOXCOR:1.002
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
9.70
8.66
5.60
8.03
67.8
77.9
48.4
67.6
309.2
295.0
272.2
291.6
3.67
2.03
3.44
2.77
19.94
20.02
24.33
21.04
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
5810
4998
4775
3.97
4.71
5.42
61
529
922
544
562
561
450
355
340
240
3.80
4.50
5.00
3.50
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 132
1965 VOLK SEDA 73 2000LBS
4CYL 1BBL 4 SPEED 089782 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, NO PCV
===================
ii
n
ii
ii
ii
ii
ii
ii
-- MAINTENANCE STATUS
I. CO
I.RPM
TIM DWL
PCV A
.CL
CHOKE
A.PMP
MISF.
FRCM OWNER 1.47
-0085
-01 -01
NA
OK
OK
NA
YES
FRCM INSP. 5.40
+0575
-01 -02
NA
OK
OK
NA
NO
— THT F TM^PPrTTHM —
LULiLi lii O JrULi 1 J-UL1 •
STATION NO. 5
I. HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
1000
250
1.00
5.40
HC
5.50
AFTER I.RPM ADJUST
1200
300
0.50
6.00
BOTH
5.50
AFTER I.MX/TM ADJ1
500
240
3.00
5.00
PASS
5.50
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
500
240
3.00
5.00
PASS
NOXC
NA
NA
16.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0296
09/12/73 BAR:24.68 DB:69 WB:60
REL.HUM:61.5% NOX COR:1.018
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.56
6.02
4.38
5.47
75.7
91.5
60.7
79.6
243.0
226.7
210.4
225.6
3.23
1.24
2.78
2.08
23.46
22.86
27.86
24.20
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
12924
4315
3128
1.76
4.61
1.91
72
1198
3889
2042
518
440
1350
240
160
360
1.50
4.20
1.80
8.10
A**A*A**A********AAAA*AA*
AS RECEIVED FROM
INS PECTION ************************
TEST NO:C0325
09/13/73 BAR:24.63
REL.HUM:26.0%
DB: 78
NOX COR:
WB:56
: .876
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.95
6.83
4.41
5.77
77.0
103.6
66.0
87.6
232.5
209.2
197.0
210.7
2.41
0.92
1.88
1.50
24.13
22.62
28.30
24.30
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
7918
4068
3038
6.00
5.15
2.37
52
986
2958
1143
707
566
465
265
190
500
5.60
4.70
2.35
9.30
AUTOMOTIVE
TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 133
1970 FORD TORI 351 3500LBS
8CYL 2BBL AUTOMATIC 045898 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
============================== MAINTENANCE STATUS ==============================
I. CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 0.60 -0100 +06 -04 BAD OK OK NA YES NA
FROM INSP. 3.00 +0040 +06 +00 BAD OK OK NA NO NA
STATION NO.
IDLE INSPECTION
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
1200
1310
4.10
4.30
BOTH
2.50
AFTER I.RPM ADJUST
1250
850
3.10
2.10
HC
2.50
AFTER I.MX/TM ADJ1
1300
850
3.40
2.10
PASS
2.50
AFTER I.MX/TM ADJ2
400
200
2. 10
2.00
HC
2.50
REPAIRS
36.00
FINAL INSPECTION
280
200
2.40
2.00
PASS
46.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0310
09/13/73 BAR:24.66 DB:69 WB:59
REL.HUM:57.7% NOX COR: .995
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.12
. 7.23
7.01
7.15
74.3
23.4
27.3
35.1
508.3
492.7
451.1
484.4
6.51
5.22
8. 14
6.30
13.75
16. 12
17.25
15.84
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
10686
6964
2939
0.79
0.14
0.74
166
2700
4230
974
1360
578
1150
750
170
****
0.80
0.20
0.70
0.60
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0347
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
09/17/73 BAR:24.92 DB:72 WB:56
REL.HUM:38.5% NOX COR: .909
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
19.50
3.58
3.80
6.97
190.2
65.9
56.9
89.4
571.4
564.2
504.8
549.3
1.75
1.63
2.11
1.79
9.55
13.11
14.69
12.51
3778
2604
2568
4.78
1.05
1.34
80
1042
1266
713
531
491
150
150
140
100
2.90
0.85
1.35
1.20
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 134
1969 DODG CORO 225 3500LBS
6CYL 1BBL AUTOMATIC 038665 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
==================1=========== MAINTENANCE STATUS ==============================
I. CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FRCM OWNER 3.90 -0030 +05 -04 OK OK OK NA NO NA
FROM INSP. 3.10 -0180 +05 -09 OK OK OK NA NO NA
STATION NO. 3
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC
175
150
250
250
2500HC
75
80
150
150
I. CO
4.60
5.00
4.00
4.00
2500CO
8.50
8.75
2.00
2.00
FAILURE
CO
CO
PASS
PASS
COST
0.00
0.00
0.00
12.00
12.00 TOT.
***************************
AS 1
RECEIVED FROM
: OWNER
***************************
TEST NO:C0311
09/13/73 BAR:24.69
DB: 70
WB:59
REL.HUM:54.5%
NOX COR
: .987
HC
CO
C02
NOX
MPG LHC
SHC
SCO
COLD TRANSIENT
9.03
190.5
366. 1
2. 19
12.83
COLD STABILIZED
3.75
73.9
374.3
3.90
17.73
HOT TRANSIENT
3.67
87.6
344.4
3.93
18.04
1975 COMPOSITE
4.83
102. 1
364.3
3.55
16.49
IDLE KEYMODE
4005
4.25
82
667
275
3.90
LOW CR. KEYMODE
3255
2.51
2141
564
225
2.50
HI. CR. KEYMODE
4082
8. 11
438
618
230
8.00
2500 RPM
180
2.80
************************* as RECEIVED FROM INSPECTION ************************
TEST NO:C0336
09/14/73 BAR:24.63 DB:76 WB:55
REL.HUM:27.0% NOX COR: .871
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.58
3.45
3.40
4.30
178.7
66.2
76.3
92.5
344.3
377.7
346.6
362.1
1.87
3.73
3.84
3.37
13.72
18.08
18.66
17.10
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3622
3031
4006
3.42
2.07
8.20
99
2440
385
560
534
612
320
255
320
195
3.10
2. 10
8.90
2.00
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 135
1969 VOLK SEDA 91 2000LBS
4CYL 1BBL 4 SPEED 068227 MILES
IDLE INSPECTION ONLY
HAS: EMC, NO EVC, NO PCV
=====
=========
=======
sasaaas:
===== MAINTENANCE STATUS
sss
I. CO
I.RPM
TIM DWL PCV A,
,CL
FRCM
OWNER
0.42
+0100
+15 -05 NA
OK
FRCM
INSP.
3.80
+0600
+00 -07 NA
OK
CHOKE A.PMP MISF. NOXC
OK NA YES NA
OK NA NO NA
STATION NO. 4
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
975
825
1.00
1.80
HC
5.00
AFTER I.RPM ADJUST
900
830
1.40
2.00
HC
1.00
AFTER I.MX/TM ADJ1
675
1000
1.80
2.50
HC
1.00
AFTER I.MX/TM ADJ2
220
100
1.40
2.30
PASS
2.50
REPAIRS
FINAL INSPECTION
220
100
1.40
2.30
PASS
9.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0313
09/13/73 BAR:24.72 DB:71 WB:56
REL.HUM:41.2% NOX COR: .918
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
8.17
5.47
4.10
5.65
117.5
85.5
84.1
91.8
268.4
280.0
219.9
260.9
2.77
2.17
1.79
2.19
18.59
20.63
24.40
21.06
9478
4117
3301
0.48
5.07
5.79
77
1142
1260
1964
692
557
1280
270
190
1000
0.50
4.60
5. 10
3.70
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0337
09/14/73 BAR:24.62 DB:76 WB:54
REL.HUM:24.3% NOX COR: .856
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.08
4.53
3.75
4.43
93.9
80.2
74.6
81.5
256.2
266.8
220.4
251.7
1.58
0.95
1.06
1.11
21.21
21.87
25.48
22.62
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3888
3280
3033
3.57
4.09
4.81
58
655
1171
426
449
443
215
200
205
240
4.00
4. 20
4.80
4.20
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 136
1965 OLDS CUTL 330 3500LBS
8CYL 2BBL AUTOMATIC 045665 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
============================== MAINTENANCE STATUS ==============================
FROM OWNER
FROM INSP.
I.CO I.RPM
4.30 +0000
4.30 +0000
TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
+00 +00 NA OK OK NA YES NA
+00 +00 NA OK OK NA YES NA
IDLE INSPECTION
STATION NO. 9
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
400
400
2500HC
480
480
I. CO
3.80
3.80
2500CO
5.80
5.80
FAILURE
PASS
PASS
COST
0.00
4.00
4.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO ::C0314
09/13/73 BAR:24.73 DB:71 WB:56
REL.HUM:41.2% NOX COR: .918
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
8.56
150.6
456.8
1.61
12.36
COLD STABILIZED
6.58
142.5
433.7
0.78
13.13
HOT TRANSIENT
6.32
132.0
390.9
1.24
14.40
1975 COMPOSITE
6.92
141.3
426.7
1.08
13.28
IDLE KEYMODE
6865
4.53
57
859
500
4.50
LOW CR. KEYMODE
4931
5.35
424
754
410
5. 20
HI. CR. KEYMODE
4554
5.15
764
679
310
4.90
2500 RPM
265
6.50
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C 0314
09/13/73 BAR:24.73 DB:71 WB:56
REL.HUM:41.2% NOX COR: .918
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
8.56
6.58
6.32
6.92
150.6
142.5
132.0
141.3
456.8
433.7
390.9
426.7
1.61
0.78
1.24
1.08
12.36
13.13
14.40
13.28
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
6865
4931
4554
4.53
5.35
5. 15
57
424
764
859
754
679
500
410
310
265
4.50
5.20
4.90
6.50
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 137
1964 CHEV STAW 327 4500LBS
8CYL 4BBL AUTOMATIC 071086 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
FRCM OWNER
FROM INSP.
«==========.==»==.=. MAINTENANCE STATUS ====
I. CO I.RPM TIM DWL PCV A.CL
1.87 +0200 +10 +04 BAD BAD
1.87 +0200 +10 +04 BAD BAD
CHOKE A.PMP MISF. NOXC
OK NA YES NA
OK NA YES NA
STATION NO. 6
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC
640
2500HC
150
640 150
I. CO
4.80
2500CO
1.60
4.80 1.60
FAILURE COST
PASS 4.50
PASS
4.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST N0:C0315
09/13/73 BAR:24.73 DB:70 WB:54
REL.HUM:37.1% NOX COR: .890
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.71
4.31
4.38
4.83
120.2
67.1
83.1
82.7
503.0
524.7
433.7
494.9
4.48
4.45
3.85
4.29
12.49
13.83
15.40
13.92
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
5807
3256
3215
2.21
1.91
3.23
117
2123
1997
833
521
500
450
205
195
125
2.00
1.90
0.90
1.70
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0315
09/13/73 BAR:24.73 DB:70 WB:54
REL.HUM:37.1% NOX COR: .890
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.71
4.31
4.38
4.83
120.2
67.1
83. 1
82.7
503.0
524.7
433.7
494.9
4.48
4.45
3.85
4.29
12.49
13.83
15.40
13.92
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
5807
3256
3215
2.21
1.91
3.23
117
2123
1997
833
521
500
450
205
195
125
2.00
1.90
0.90
1.70
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 139
1970 FORD TORI 250 3500LBS
6CYL 1BBL 3 SPEED 031895 MILES
COMBINATION RETROFIT
HAS: EMC, NO EVC, PCV
FROM OWNER
FROM INSP.
MAINTENANCE STATUS am=
I.CO I.RPM TIM DWL PCV A.CL
1.90 -0210 -12 +00 OK BAD
1.90 -0150 -12 -09 OK BAD
CHOKE A.PMP MISF. NOXC
OK NA YES NA
OK NA YES NA
STATION NO. 1
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
400
150
150
2500HC
120
150
120
I. CO
3.00
2.10
2.10
2500CO
2.40
1.40
1.40
FAILURE
HC
PASS
PASS
COST
2.50
3.00
4.47
9.97 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:.C0326
09/14/73 BAR:24.80 DB:71 WB:59
REL.HUM:51.4% NOX COR: .977
HC
CO
C02
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.43
3.65
4.34
4.63
88.6
59.5
74.7
69.8
389.9
426.8
347.0
397.0
2.72
2.35
2.46
2.46
16.11
16.75
18.63
17.09
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2543
3413
2983
2.07
2.45
2.63
73
1382
1637
225
569
519
70
195
130
2500 RPM
130
SCO
2.20
2.40
2.45
3.40
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0338
09/17/73 BAR:24.82 DB:69 WB:56
REL.HUM:46.6% NOX COR: .930
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.03
3.28
3.44
3.69
77.9
56.2
64.9
63.2
421.0
456.0
376.0
426.5
3. 15
2.54
2.31
2.60
15.92
16.05
18.21
16.57
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2097
2882
2621
2.10
2.42
2.03
101
1423
1850
145
287
347
100
225
190
160
2.20
2.50
2.30
4. 10
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 140
1966 OLDS DYNA 425 4500LBS
8CYL 2BBL AUTOMATIC 048553 MILES
SEA LEVEL RETROFIT
HAS: NO EMC, NO EVC, PCV
FRCM OWNER
FROM INSP.
»================ MAINTENANCE STATUS ===
I. CO I.RPM TIM DWL PCV A.CL
0.75 -0060 +02 +01 OK BAD
0.50 +0000 +00 +00 OK BAD
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
STATION NO. 2
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC
****
* ***
¦kit-kit
****
2500HC
1500
1600
1550
1550
I. CO
0.40
0.50
0.50
0.50
2500CO
3.40
3.60
3.60
3.60
FAILURE
BOTH
BOTH
BOTH
COST
0.00
0.00
0.00
12.10
BOTH 200.00 EST.
12.10 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0327
09/14/73 BAR:24.80 DB:70 WB:59
REL.HUM:54.5% NOX COR: .985
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
9.11
4.73
5.15
5.76
208.5
99.4
113.3
126. 1
654.3
670.9
557.0
635.8
1.88
1.44
1.88
1.66
8.81
10.58
11.85
10.45
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2965
3115
3511
0.86
1.96
4.25
116
634
767
450
464
496
130
140
170
105
0.70
0.80
4.30
3.10
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0339
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
09/17/73 BAR:24.82 DB:69 WB:57
REL.HUM:50.2% NOX COR: .950
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
47.07
57.64
43.57
51.53
220.8
181.9
169.3
186.5
595.7
582.2
478.5
556.2
1.90
1.11
1.22
1.31
8.16
8.48
10.09
8.80
29685
37615
36367
0.65
6.68
6.23
128
97
163
A AAA
A AAA
AAA*
A AAA
AAA A
AAA A
A AAA
0.60
7.00
6.90
3.20
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 141
1972 TOYO STAW 120 2750LBS
4CYL 2BBL AUTOMATIC 009840 MILES
IDLE INSPECTION ONLY
HAS: EMC, EVC, PCV
FROM OWNER
FROM INSP.
MAINTENANCE STATUS ===
I.CO I.RPM TIM DHL PCV A.CL
3.20 -0010 +00 -01 OK OK
3.20 -0010 +00 -01 OK OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
STATION NO. 5
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
320
IDLE INSPECTION
2500HC
110
320 110
I.CO 2500CO
3.00 2.00
3.00 2.00
FAILURE COST
PASS 5.50
PASS
5.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0328
09/14/73 BAR:24.80 DB:70 WB:59
REL.HUM:54.5% NOX COR: .985
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
3.65
2.38
2.05
2.55
62.5
43.8
35.3
45.4
392.8
369.8
353.6
370.1
5.25
2.37
5.48
3.84
17.72
19.96
21.43
19.82
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3915
2569
2523
4.07
1.03
0.45
70
872
3513
615
412
414
220
120
110
95
3.30
1.20
0.50
2.20
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0328
09/14/73 BAR:24.80 DB:70 WB:59
REL.HUM:54.5% NOX COR: .985
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
3.65
2.38
2.05
2.55
62.5
43.8
35.3
45.4
392.8
369.8
353.6
370.1
5.25
2.37
5.48
3.84
17.72
19.96
21.43
19.82
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3915
2569
2523
4.07
1.03
0.45
70
872
3513
615
412
414
220
120
110
95
3. 30
1. 20
0.50
2. 20
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 142
1972 CHEV NOVA 350 3500LBS
8CYL 2BBL AUTOMATIC 025592 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, EVC, PCV
====¦========================== MAINTENANCE STATUS ==============================
I. CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 1.30 +0000 +10 -04 BAD BAD OK NA NO NA
FROM INSP. 1.30 +0000 +10 -04 BAD BAD OK NA NO NA
STATION NO. 9
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC
80
80
2500HC
90
90
I. CO
0.20
2500CO
0.50
0.20 0.50
FAILURE
PASS
PASS
COST
0.00
4.00
4.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0346
09/17/73 BAR:24.92 DB:72 WB:56
REL.HUM:38.5% NOX COR: .909
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.73
3.80
3.20
4.25
124.9
36.4
37.7
55.3
578.1
594.4
497.7
564.2
4.21
2.88
4.60
3.63
11.19
13.42
15.70
13.40
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2853
3028
2367
1.20
1.24
0.23
361
1788
2956
530
603
490
220
220
130
135
1.50
1.30
0.25
1.60
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO-.C0346
09/17/73 BAR:24.92 DB:72 WB:56
REL.HUM:38.5% NOX COR: .909
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.73
3.80
3.20
4.25
124.9
36.4
37.7
55.3
578.1
594.4
497.7
564.2
4.21
2.88
4.60
3.63
11.19
13.42
15.70
13.40
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2853
3028
2367
1.20
1.24
0.23
361
1788
2956
530
603
490
220
220
130
135
1.50
1.30
0.25
1.60
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 143
1966 FORD MUST 289 3000LBS
8CYL 2BBL AUTOMATIC 038659 MILES
SEA LEVEL RETROFIT
HAS: NO EMC, NO EVC, PCV
MAINTENANCE STATUS
I.CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FRCM OWNER 3.40 -0135 -06 -02 OK OK OK NA NO NA
FRCM INSP. 3.40 -0135 -06 -02 OK OK OK NA NO NA
STATION NO. 4
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC
280
2500HC
170
280 170
I. CO
2.90
2500CO
1.20
2.90 1.20
FAILURE COST
PASS 5.00
PASS
5.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0340
09/17/73 BAR:24.83 DB:70 WB:58
REL.HUM:50.8% NOX COR: .963
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
11.01
8.47
5.67
8.22
110.0
89.3
53.6
83.7
459.4
416.4
400.9
421.1
3.16
3.00
3.97
3.30
13.35
15.26
17.70
15.39
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
5604
5329
4664
3.53
1.00
1.44
60
2211
1954
954
953
777
580
560
400
270
3.70
1. 10
1.50
6.80
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0340
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
09/17/73 BAR:24.83 DB:70 WB:58
REL.HUM:50.8% NOX COR: .963
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
11.01
8.47
5.67
8.22
110.0
89.3
53.6
83.7
459.4
416.4
400.9
421.1
3.16
3.00
3.97
3.30
13.35
15.26
17.70
15.39
5604
5329
4664
3.53
1.00
1.44
60
2211
1954
954
953
777
580
560
400
270
3.70
1.10
1.50
6.80
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 144
1972 FORD GALA 400 4000LBS COMBINATION RETROFIT
8CYL 2BBL AUTOMATIC 012721 MILES HAS: EMC, EVC, PCV
============================= MAINTENANCE STATUS ==============================
I. CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 5.30 40040 -08 +09 OK OK OK NA NO NA
FRCM INSP. 3.40 +0050 -08 +08 OK OK OK NA YES NA
IDLE INSPECTION
STATION NO. 8
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
150
50
4.40
0.80
BOTH
3.50
AFTER I.RPM ADJUST
150
50
4.40
0.80
BOTH
2.00
AFTER I.MX/TM ADJ1
180
50
3.20
0.50
PASS
2.50
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
180
50
3.20
0.50
PASS
8.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0342
09/17/73 BAR:24.82 DB:70 WB:56
REL.HUM:43.8% NOX COR: .924
HC
CO
C02
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.43
4.37
4.00
4.49
88.0
81.9
5L.0
74.6
639.6
636.8
537.2
609.8
4.73
3.85
5.25
4.42
11.20
11.43
14.14
12.02
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
3407
3076
2979
5.37
0.81
0.87
85
2015
2564
493
527
485
235
220
175
2500 RPM
110
SCO
5.40
0.80
1.00
4.40
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0353
09/18/73 BAR:24.80 DB:72 WB:60
REL.HUM:52.0% NOX COR: .992
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
3.39
3.01
3.28
3.16
60.0
72.6
53.8
64.8
771.7
741.7
614.5
712.7
3.55
2.24
2.82
2.68
10. 16
10.29
12.55
10.80
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2899
1101
1215
3.46
0.94
0.63
117
633
1472
300
221
231
255
85
79
48
3.50
1.10
0.65
1.40
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 145
1973 FORD MAVE 302 3000LBS
8CYL 2BBL AUTOMATIC 005516 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, EVC, PCV
=============
II
ii
ii
ii
ii
ii
ii
=======
===« MAINTENANCE STATUS
I. CO
I.RPM
TIM DWL PCV A.
.CL
CHOKE
A.PMP
MISF.
NOXC
FROM OWNER
1.08
+0010
+00 +00 OK
OK
OK
NA
NO
OK
FRCM INSP.
1.08
+0010
+00 +00 OK
OK
OK
NA
NO
OK
STATION NO. 10
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
— IDLE INSPECTION
I.HC
150
2500HC
100
150 100
I. CO
0.15
2500CO
0.80
0.15 0.80
FAILURE COST
PASS 1.50
PASS
1.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0343
09/17/73 BAR:24.85 DB:70 WB:56
REL.HUM:43.8% NOX COR: .923
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
4.82
64.2
519.8
2.03
14.00
COLD STABILIZED
3.56
55.8
552.6
1.82
13.67
HOT TRANSIENT
3.95
42.3
470.9
2.40
16.19
1975 COMPOSITE
3.93
53.8
523.1
2.03
14.36
IDLE KEYMODE
2945
1. 10
123
545
240
1.30
LOW CR. KEYMODE
3077
1. 10
1140
531
230
1.20
HI. CR. KEYMODE
3185
1.42
1430
548
245
1.50
2500 RPM
115
1.70
AAAA*******A*AAAAAA*&***&
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0343
09/17/73 BAR:24.85 DB:70 WB:56
REL.HUM:43.8% NOX COR: .923
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.82
3.56
3.95
3.93
64.2
55.8
42.3
53.8
519.8
552.6
470.9
523.1
2.03
1.82
2.40
2.03
14.00
13.67
16. 19
14.36
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2945
3077
3185
1. 10
1. 10
1.42
123
1140
1430
545
531
548
240
230
245
115
1.30
1.20
1.50
1.70
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 146
1969 OLDS DELT 455 4000LBS
8CYL 2BBL AUTOMATIC 061594 MILES
COMBINATION RETROFIT
HAS: EMC, NO EVC, PCV
MAINTENANCE STATUS =============================
I. CO I.RPM TIM DWL PCV A.CL
FRCM OWNER 9.15 -0010 -06 +04 OK BAD
FRCM INSP. 2.20 +0350 +06 +04 OK BAD
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 6
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
310
150
150
2500HC
230
80
80
I.CO 2500CO
9.40 4.60
2.80 3.20
2.80
3.20
FAILURE
CO
PASS
PASS
COST
4.50
1.50
6.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0341
09/17/73 BAR:24.83 DB:70 WB:56
REL.HUM:43.8% NOX COR: .923
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
11.56
6.76
5.30
7.36
206.4
172.4
126.0
166.6
600.7
580.6
513.3
566.1
2.73
2. 13
2.77
2.43
9.26
10.20
12.23
10. 46
5378
3719
3130
9.57
3.01
2.54
44
992
1657
560
573
483
290
270
175
180
9.60
3.80
2.70
4.40
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* as RECEIVED FROM INSPECTION ************************
TEST NO:C0354
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
09/18/73 BAR:24.80 DB:74 WB:59
REL.HUM:43.2% NOX COR: .955
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
5.17
4.64
3.94
4.56
107.7
95.5
76.1
92.6
650.4
713.9
583.0
664.3
3.90
2.80
3.57
3.24
10.65
10. 14
12.45
10.81
2784
3000
2534
2.36
2.45
1.90
259
812
1896
343
438
372
230
265
,180
165
2.50
2.60
2. 10
3.90
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 147
1970 CHEV IMPA 350 4000LBS
8CYL 2BBL AUTOMATIC 080466 MILES
TUNE UP EVALUATION
HAS: EMC, NO EVC, PCV
============================= MAINTENANCE STATUS
I. CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 6.07 +0050 +00 +02 OK BAD OK NA YES NA
FROM INSP. 5.60 +0000 +00 +01 OK OK OK NA NO NA
IDLE INSPECTION
STATION NO.
I.HC
2500HC
I. CO
2500C0
FAILURE
COST
INITIAL INSPECTION
1500
200
4.00
1.20
HC
0.00
AFTER I.RPM ADJUST
900
150
4.50
1.20
BOTH
0.00
AFTER I.MX/TM ADJ1
340
150
3.90
1.00
BOTH
0.00
AFTER I.MX/TM ADJ2
200
60
2.20
1.50
PASS
0.00
REPAIRS
18.00
FINAL INSPECTION
200
60
2.20
1.50
PASS
18.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0345
09/17/73 BAR:24.87 DB:70 WB:56
REL.HUM:43.7% NOX COR: .923
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
11.61
7.88
6.01
8.14
188.0
104.8
82.6
116.0
548.0
573.9
455.8
535.7
1.97
2.26
2.34
2.22
10. 12
11.66
14.73
11.98
6254
3340
3584
6.82
1.36
3.52
153
1300
1287
863
532
549
800
230
250
115
6.30
1.60
3.50
1.40
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO.-C0379
09/19/73 BAR:24.68 DB:83 WB:55
REL.HUM:15.8% NOX COR: .832
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
9.37
4.49
4.39
5.48
160.5
73. 2
77.4
92.7
470.0
504.7
429.0
476.4
1.77
1.91
1.98
1.90
11.84
14.05
15.78
13.93
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4890
3441
3751
5.84
1.40
3.28
65
1302
1217
613
436
477
520
280
295
175
5.80
1.55
3.60
1.90
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 148
1972 PLYM SATE 400 3500LBS
8CYL 2BBL AUTOMATIC 014660 MILES
SEA LEVEL RETROFIT
HAS: EMC, EVC, PCV
============================== MAINTENANCE STATUS ==============================
I. CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 6.40 +0090 +00 +00 OK BAD OK NA NO NA
FROM INSP. 2.45 -0020 +00 +00 OK BAD OK NA NO NA
IDLE INSPECTION —
STATION NO.
I.HC
2500HC
I. CO
2500C0
FAILURE
COST
INITIAL INSPECTION
140
40
5.50
2.50
CO
0.00
AFTER I.RPM ADJUST
170
40
5.10
2.20
CO
0.00
AFTER I.MX/TM ADJ1
160
40
1.50
2.00
PASS
0.00
AFTER I.MX/TM ADJ2
REPAIRS
12.00
FINAL INSPECTION
160
40
1.50
2.00
PASS
12.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0357 09/18/73 BAR:24.79 DB:71 WB:53
REL.HUM:31.4% NOX COR: .868
SCO
HC
CO
CO 2
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
8.62
5.60
4.52
5.93
184.3
142.5
103.3
140.4
530.2
538.0
472.5
518.2
1.91
1.29
2. 17
1.66
10.51
11.42
13.72
11.76
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
4666
3285
3250
7.27
2.76
3.29
55
960
1533
517
475
462
380
270
255
2500 RPM
130
6.50
2.80
3.40
3.00
************************* as RECEIVED FROM INSPECTION ************************
TEST NO:C0367
09/19/73 BAR:24.65 DB:73 WB:55
REL.HUM:33.2% NOX COR: .889
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.16
3.96
3.87
4.61
140.3
79.5
77.3
91.6
486.6
534.9
439.9
498.5
1. 71
1.38
1.82
1.57
12.20
13.24
15.52
13.56
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3339
3107
3262
3.09
2.15
3.00
57
889
1449
366
362
381
255
250
255
110
2.70
2.30
3.30
2. 20
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 149
1966 FORD GALA 352 4000LBS
8CYL 4BBL AUTOMATIC 078274 MILES
TUNE UP EVALUATION
HAS: NO EMC, NO EVC, PCV
============================== MAINTENANCE STATUS
I.CO I.RPM TIM DWL PCV A.CL
FROM OWNER 6.60 +0060 +10 -04 OK OK
FROM INSP. 1.60 -0070 +00 -03 OK OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 5
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
620
600
480
480
2500HC
180
180
160
160
I. CO
8.20
6.80
2.80
2.80
2500CO
1.80
2.30
2.30
2.10
FAILURE
CO
CO
BOTH
PASS
COST
5.50
5.50
5.50
16.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO :,C0344
09/17/73 BAR:24.86 DB:70 WB:56
REL.HUM:43.8% NOX COR: .923
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
10. 66
8.78
6.57
8.56
129.6
136.5
95.2
123.6
518. 1
478.2
440.1
4 76.0
4.39
3.59
3.72
3.80
11.79
12.36
14.59
12.78
5055
3610
3740
6.85
2. 15
2.31
92
1727
2330
751
610
630
505
410
300
210
7.20
2.60
2.55
3.00
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0362
09/18/73 BAR:24.78 DB:77 WB:53
REL.HUM:19.8% NOX COR: .834
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
9.18
6.98
5.70
7.09
113.1
85. 2
68.3
86.4
494.3
488.7
451.1
479.4
3.93
3.67
3.81
3.76
12.70
13.81
15.45
13.97
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4163
4205
3749
1.90
2.29
2.08
245
1888
2341
562
599
518
410
450
340
255
1.55
2.30
2. 10
2.90
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 150
1971 DODG DART 318 3000LBS
8CYL 2BBL AUTOMATIC 026700 MILES
COMBINATION RETROFIT
HAS: EMC, NO EVC, PCV
=========== MAINTENANCE STATUS
FROM OWNER
FROM INSP.
I.CO I.RPM
7.50 +0030
2.20 +0020
TIM DWL
+05 +00
+05 +00
PCV
OK
OK
A.CL
OK
OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 1
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
310
180
180
2500HC
200
150
150
I. CO
7.00
2.00
2.00
2500CO
1.10
1.00
1.00
FAILURE
CO
PASS
PASS
COST
2.50
3.00
5.50 TOT.
***************************
AS RECEIVED FROM OWNER
***************************
TEST NO:C0358
09/18/73 BAR:24.80
DB : 72
WB: 54
REL.HUM:32.3%
NOX COR:
.877
HC
CO
C02
NOX
MPG LHC
SHC
SCO
COLD TRANSIENT
6.02
86. 1
449.5
3.46
14.75
COLD STABILIZED
6.68
112.9
430.4
2.29
14. 16
HOT TRANSIENT
4.51
61.8
401.4
3.81
17.37
1975 COMPOSITE
5.94
93.1
426.4
2.95
15.06
IDLE * KEYMODE
6092
8.54
49
667
620
7.70
LOW CR. KEYMODE
3801
1. 19
1969
529
420
1.20
HI. CR. KEYMODE
3655
2.58
1731
464
350
2.70
2500 RPM
250
2.40
************************* AS RECEIVED FROM INSPECTION ************************
TEST N0-.C0368
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
09/19/73 BAR:24.65 DB:71 WB:56
REL.HUM:41.2% NOX COR: .919
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
5.16
4.31
3.77
4.34
55.3
53. 1
41.7
50.4
481.9
468.2
395.0
450.7
3.58
2.44
3.20
2.89
15.22
15.76
18.85
16.38
3340
3722
3561
2.43
0.65
2.16
88
2297
2024
417
512
441
335
390
330
180
2.40
0.75
8.80
1. 10
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 151
1971 VOLV 145S 121 3000LBS
4CYL 2BBL 4 SPEED 045943 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
FROM OWNER
FROM INSP.
I.CO I.RPM
1.30 +0000
1.30 +0000
MAINTENANCE STATUS
TIM DWL PCV A.CL
+04 +05 OK BAD
+04 +05 OK BAD
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
STATION NO. 4
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
205
IDLE INSPECTION
2500HC
150
205 150
I. CO
1.90
2500CO
1.80
1.90 1.80
FAILURE COST
PASS 5.00
PASS
5.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0359
09/18/73 BAR:24.80 DB:76 WB:54
REL.HUM:24.2% NOX COR: .854
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.05
3.00
3.25
3.29
42.9
26.3
30.5
30.9
356.9
361.8
331.2
352.3
5.67
4. 10
5.51
4.82
: 0. 37
21.58
22.87
21.66
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2346
2513
2618
1.65
1.06
1.54
137
2836
4197
333
411
418
165
255
250
120
1.50
1.00
1.60
0.50
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0359
09/18/73 BAR
REL.HUM:
:24.80
24.2%
DB :76
NOX COR:
WB: 54
.854
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.05
3.00
3.25
3.29
42.9
26.3
30.5
30.9
356.9
361.8
331.2
352.3
5.67
4. 10
5.51
4.82
20.37
21.58
22.87
21.66
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2346
2513
2618
1.65
1.06
1.54
137
2836
4197
333
411
418
165
255
250
1.50
1.00
1.60
2500 RPM
120
0.50
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 152
1971 FORD GALA 351 4000LBS
8CYL 2BBL AUTOMATIC 029562 MILES
COMBINATION RETROFIT
HAS: EMC, NO EVC, PCV
*============= MAINTENANCE STATUS ==
I.CO I.RPM TIM
DWL
PCV A.CL CHOKE A.PMP MISF.
FRCM OWNER 4.00
40000
+02 +00
OK
BAD
OK
NA
NO
FROM INSP. 4.70
+0000
+02 +00
OK
BAD
OK
NA
NO
STATION NO. 6
IDLE INSPECTION
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
****
2000
2.40
0.
70
HC
4.50
AFTER I.RPM ADJUST
****
****
3.40
0.
70
BOTH
1.50
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
2000
2000
2.00
0.
90
HC
3.00
REPAIRS
25.51
FINAL INSPECTION
1300
600
1.20
0.
30
HC
NOXC
NA
NA
34.51 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0369
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
*************************
TEST NO:CA383
COLD TRANSIENT
COLD STABILIZED
HOT v TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
09/19/73 BAR:24.66 DB:71 WB:56
REL.HUM:41.2% NOX COR: .919
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
30.94
30.40
26.44
29.42
95.0
81.4
63.2
79,2
492.3
548.7
455.4
511.0
3.41
4.23
4.92
4.25
12.04
11.52
13.95
12.22
10833
10771
10767
4.74
0.92
2.50
94
2112
1788
* ***
****
****
****
****
****
****
4.50
0.90
2.60
1.35
AS RECEIVED FROM INSPECTION ************************
09/20/73 BAR:24.71 DB:71 WB:56
REL.HUM:41.2% NOX COR: .918
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
8.01
6.23
6.30
6.62
83.7
80.7
69.5
78.2
539.6
521.0
461.5
508.4
5.33
4.18
5.26
4.72
12.79
13.34
15.07
13.66
5325
3923
3513
4.94
1.13
1.36
131
2503
3052
654
483
417
515
320
240
190
5.00
1.20
1.40
1.40
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 153
1965 CHEV BELA 283 4000LBS
8CYL 2BBL AUTOMATIC 130460 MILES
SEA LEVEL RETROFIT
HAS: NO EMC, NO EVC, NO PCV
MAINTENANCE STATUS ==============================
I.CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FRCM OWNER 2.40 +0000 +02 +01 NA BAD OK NA NO NA
FROM INSP. 2.40 +0000 +02 +01 NA BAD OK NA NO NA
STATION NO. 8
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC
600
600
2500HC
400
400
I. CO
1.80
1.80
2500CO
3.80
3.80
FAILURE
PASS
PASS
COST
3.50
3.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0370 09/19/73 BAR:24.67 DB:72 WB:56
REL.HUM:38.7% NOX COR: .912
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
HC
CO
CO 2
NOX
MPG
LHC
SHC
11.44
8.51
7.77
8.92
151.3
160.5
141.5
153.3
418.8
394.9
349. 8
387.4
1.81
0.62
1. 18
1.02
12.85
13.21
14.92
13.57
5367
5454
5891
2.65
4.72
7.52
88
628
406
776
776
783
m
620
SCO
550
2.75
4.70
8.00
5.00
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0370
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
09/19/73 BAR:24.67 DB:72 WB:56
REL.HUM:38.7% NOX COR: .912
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
11.44
8.51
7.77
8.92
151.3
160.5
141.5
153.3
418.8
394.9
349.8
387.4
1.81
0.62
1. 18
1.02
12.85
13.21
14.92
13.57
5367
5454
5891
2.65
4.72
7.52
88
628
406
776
776
783
700
640
620
550
2.75
4. 70
8.00
5.00
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 154
1968 VOLK SEDA 91 2000LBS
4CYL 1BBL AUTOMATIC 050486 MILES
IDLE INSPECTION ONLY
HAS: EMC, NO EVC, NO PCV
============================== MAINTENANCE STATUS ==============================
FRCM CWNER
FROM INSP.
I. CO I.RPM
8.90 -0260
10.20 +0050
TIM DWL PCV A.CL
+02 +00 NA OK
+09 +00 NA OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
STATION NO.
IDLE INSPECTION
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
1200
1200
10.00
10.00
BOTH
2.50
AFTER I.RPM ADJUST
1200
1200
10.00
10.00
BOTH
2.50
AFTER I.MX/TM ADJ1
1200
1200
10.00
10.00
BOTH
2.50
AFTER I.MX/TM ADJ2
1250
1200
10.00
10.00
BOTH
2.50
REPAIRS
3.50
FINAL INSPECTION
1250
"1200
10.00
10.00
BOTH
40.00
13.50 TOT.
***************************
TEST NO:C0371
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
AS RECEIVED FROM OWNER ***************************
09/19/73 BAR:24.68 DB:70 WB:52
REL.HUM:30.6% NOX COR: .860
SCO
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
HC
CO
C02
NOX
MPG
LHC
SHC
11.67
19.72
10.70
15.53
113.7
164.8
106.2
137.8
250.0
202.7
207.3
213.9
2. 11
0.70
1.42
1. 19
19.13
16.99
21.82
18.57
32148
6234
4715
10.72
7.41
5.47
16
377
1307
****
862
617
****
710
440
890
ick'k'k'k
8.10
5.60
************************* as RECEIVED FROM INSPECTION ************************
TEST NO:C0394
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
09/20/73 BAR:24.58 DB:78 WB:56
REL.HUM:26.1% NOX COR: .876
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
9.43
16.23
10. 11
13. 11
115.5
181.8
120.5
150.9
260.8
217.0
228.4
229.3
2.92
0.88
1.88
1.59
18.86
16.07
19.80
17.54
29266
4905
3770
11.95
4.64
6.01
14
1513
1240
****
552
418
•kifkJc
530
340
****
*****
4.70
6.10
*****
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 155
1968 CHEV BELA 307 4000LBS
8CYL 2BBL AUTOMATIC 066417 MILES
COMBINATION RETROFIT
HAS: EMC, NO EVC, PCV
MAINTENANCE STATUS
I.CO I.RPM TIM DWL PCV A.CL
FROM OWNER 7.40 -0135 +08 -01 OK OK
FROM INSP. 2.55 -0100 -01 -02 OK OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 10
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
1300
350
6.50
1.20
BOTH
1.50
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
750
250
3.00
0.60
HC
1.50
AFTER I.MX/TM ADJ2
300
150
0.70
1.10
PASS
1.50
REPAIRS
FINAL INSPECTION
300
150
0.70
1.10
PASS
4.50 TOT.
***************************
AS RECEIVED !
FROM OWNER
***************************
TEST NO:C0384
09/20/73 BAR:24.71
DB : 72
WB: 58
REL.HUM:
45. 2%
NOX COR
: .950
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
8.93
75.9
503.3
7.23
13.68
COLD STABILIZED
9.34
62.3
475.3
5.89
14.77
HOT TRANSIENT
6.58
50.1
460.7
7.91
15.90
1975 COMPOSITE
8.49
61.8
477.1
6.73
14.82
IDLE KEYMODE
9200
8.27
26
1264
320
7.60
LOW CR. KEYMODE
4098
0.63
3049
518
400
0.70
HI. CR. KEYMODE
3646
0.60
4117
417
275
0.65
2500 RPM
370
4.50
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0396
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM '
09/21/73 BAR:24.54 DB:71 WB:52
REL.HUM:28.5% NOX COR: .855
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
8.13
6.03
5.43
6.30
107.5
55.5
66.4
69.4
528.5
502.5
455.3
494.9
3.86
2.91
3.88
3.38
12.31
14.63
15.44
14.28
5302
3815
3229
3.01
1.22
1.00
63
1711
2505
589
409
326
519
320
215
200
2.90
1.20
1.05
1.70
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 156
1971 VOLK SEDA 97 2000LBS
4CYL 1BBL 4 SPEED 024425 MILES
SEA LEVEL RETROFIT
HAS: EMC, NO EVC, NO PCV
============================== MAINTENANCE STATUS ==============================
I. CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FRCM OWNER 3.99 -0055 400 +01 NA OK OK NA NO NA
FROM INSP. 3.99 -0055 +00 *+01 NA OK OK NA NO NA
STATION NO. 4
INITIAL INSPECTION
AFTER I.RPM ADJUS
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC
220
2500HC
120
220 120
I. CO
1.30
2500C0
0.70
1.30 0.70
FAILURE COST
PASS 5.00
PASS
5.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST N0:C0385
09/20/73 BAR:24.70 DB:71 WB:56
REL.HUM:41.2% NOX COR: .919
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.73
3.61
3.62
3.85
60.4
73.8
53.9
65.5
288.7
291.8
252.5
280. 2
3.02
1.49
2.48
2.09
22.34
21.25
25.54
22.54
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4240
3281
2859
4.66
3.78
2.39
72
991
2298
441
381
342
335
270
210
160
4. 10
3.90
2.50
1.90
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0385
09/20/73 BAR:24.70 DB:71 WB:56
REL.HUM:41.2% NOX COR: .919
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.73
3.61
3.62
3.85
60.4
73.8
53.9
65.5
288.7
291.8
252.5
280.2
3.02
1.49
2.48
2.09
22.34
21.25
25.54
22.54
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4240
3281
2859
4.66
3. 78
2.39
72
991
2298
441
381
342
335
270
210
160
4. 10
3.90
2.50
1.90
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 157
1973 VOLK SEDA 97 2000LBS
4CYL 1BBL 4 SPEED 007972 MILES
IDLE INSPECTION ONLY
HAS: EMC, EVC, NO PCV
============================== MAINTENANCE STATUS
I.CO I.RPM TIM DWL PCV A.CL CHOKE
FROM OWNER 5.60 -0260 -02 +00 NA OK OK
FROM INSP. 5.60 -0260 -02 +00 NA OK OK
A.PMP MISF. NOXC
NA NO NA
NA NO NA
STATION NO. 5
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM AD J2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION —
I.HC
210
2500HC
140
210 140
I. CO
3.20
2500CO
2.40
3.20 2.40
FAILURE COST
PASS 5.50
PASS
5.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO ::C0386
09/20/73 BAR:24.70 DB:72 WB:57
REL.HUM:41.9% NOX COR: .931
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.83
5.53
4.38
5.27
79.4
62.8
57.5
64.8
274.6
283.2
240.5
269.5
2.97
1.93
2.41
2.28
21.32
22.30
25.84
22.96
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
5266
3101
2953
6.16
1.54
1.56
63
1273
2765
443
283
290
350
200
190
2500 RPM
210
6.00
1.65
1.60
2.60
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0386
09/20/73 BAR:24.70 DB:72 WB:57
REL.HUM:41.9% NOX COR: .931
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.83
5.53
4.38
5.27
79.4
62.8
57.5
64.8
274.6
283.2
240.5
269.5
2.97
1.93
2.41
2.28
21.32
22.30
25.84
22.96
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
5266
3101
2953
6.16
1.54
1.56
63
1273
2765
443
283
290
350
200
190
210
6.00
1.65
1.60
2.60
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 158
1970 OLDS STAW 455 4500LBS
8CYL 4BBL AUTOMATIC 033747 MILES
IDLE INSPECTION ONLY
HAS: EMC, NO EVC, NO PCV
FROM OWNER
FROM INSP.
:== =============== MAINTENANCE STATUS ===========
I. CO I.RPM TIM DWL PCV A.CL CHOKE
1.50 -0005 -02 +01 BAD BAD OK
1.50 -0005 -02 +01 BAD BAD OK
A.PMP MISF. NOXC
NA NO NA
NA NO NA
IDLE INSPECTION
STATION NO. 9
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
180
180
2500HC
100
100
I. CO
1.20
1.20
2500CO
0.90
0.90
FAILURE
PASS
PASS
COST
0.00
4.00
4.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST N0:C0387
09/20/73 BAR:24.70 DB:71 WB:54
REL.HUM:34.7% NOX COR: .884
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.69
4.89
4.41
5.13
91.2
67.5
56.3
69.3
734.8
698.9
630.9
687.5
5.05
3.44
4.97
4.20
9.90
10.86
12. 14
10.96
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3004
3307
2903
1.60
1.60
1.03
80
1410
2172
277
383
311
180
240
162
80
1.90
1.80
1.10
1.50
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0387
09/20/73 BAR
REL.HUM:
:24.70
34.7%
DB: 71
NOX COR
WB:54
: .884
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.69
4.89
4.41
5.13
91.2
67.5
56.3
69.3
734.8
698.9
630.9
687.5
5.05
3.44
4.97
4.20
9.90
10.86
12.14
10.96
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3004
3307
2903
1.60
1.60
1.03
80
1410
2172
277
383
311
180
240
162
80
1.90
1.80
1.10
1.50
AUTOMOTIVE
TESTING LABORATORIES,INC.
-------
*** COLORADO-393 ***
VEHICLE 159
1968 CHEV BELA 250 4000LBS
6CYL 1BBL AUTOMATIC 009065 MILES
IDLE INSPECTION ONLY
HAS: EMC, NO EVC, PCV
MAINTENANCE STATUS =============================
I.CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FRCM OWNER 1.40 -0060 +00 +02 OK BAD OK OK YES NA
FRCM INSP. 1.40 -0060 +00 +02 OK BAD OK OK YES NA
IDLE INSPECTION
STATION NO. 2
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
230
230
2500HC
250
250
I. CO
2.40
2500CO
0.50
2.40 0.50
FAILURE
PASS
PASS
COST
5.50
5.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0395
09/20/73 BAR:24.58 DB:77 WB:56
REL.HUM:27.9% NOX COR: .882
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
10.06
5.54
5.81
6.56
132.1
90.0
96.0
100.5
383.0
410.5
356.3
389.7
2.27
1.63
2.29
1.94
14.31
15.64
16.94
15.67
1745
2247
4243
1.78
1.61
7.09
54
2100
552
272
333
526
60
95
270
460
1.40
1.30
6.20
0.42
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0395
09/20/73 BAR:24.58 DB:77 WB:56
REL.HUM:27.9% NOX COR: .882
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
10.06
5.54
5.81
6.56
132.1
90.0
96.0
100.5
383.0
410.5
356.3
389.7
2.27
1.63
2.29
1.94
14.31
15.64
16.94
15.67
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
1745
2247
4243
1. 78
1.61
7.09
54
2100
552
272
333
526
60
95
270
460
1.40
1.30
6.20
0.42
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 160
1969 CADI FLEE 472 5000LBS
8CYL 4BBL AUTOMATIC 036519 MILES
IDLE INSPECTION ONLY
HAS: EMC, NO EVC, PCV
===3=mz3====o=j=3================ MAINTENANCE STATUS ======================
I. CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 0.10 -0130 +00 +01 OK OK OK NA NO NA
FROM INSP. 0.10 -0130 -K)0 +01 OK OK OK NA NO NA
IDLE INSPECTION
STATION NO. 6
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
200
200
2500HC
160
160
I. CO
0.60
0.60
2500CO
0.50
0.50
FAILURE
PASS
PASS
COST
4.50
4.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0416
09/24/73 BAR:24.52 DB:70 WB:57
REL.HUM:47.5% NOX COR: .947
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
7. 10
11.48
7.53
9.47
68.7
34.8
72.5
52.3
586.9
622.6
586.8
605.2
4.37
5.12
5.77
5.14
12.41
12.48
12.29
12.42
20696
5681
4208
0.40
1.28
0.45
280
2089
2868
0
715
495
****
390
270
170
0.10
1. 10
0.45
0.35
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0416
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
09/24/73 BAR: 24.52 DB:70 WB:57
REL.HUM:47.5% NOX COR: .947
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
7.10
11.48
7.53
9.47
68.7
34.8
72.5
52.3
586.9
622.6
586.8
605.2
4.37
5.12
5.77
5. 14
12.41
12.48
12.29
12.42
20696
5681
4208
0.40
1.28
0.45
280
2089
2868
0
715
495
****
390
270
170
0.10
1. 10
0.45
0.35
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 161
1969 MERC COUG 351 3500LBS
8CYL 2BBL AUTOMATIC 047191 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
============================= MAINTENANCE STATUS
I. CO I.RPM TIM DWL PCV A.CL
FRCM OWNER 0.30 -0050 -06 +00 OK BAD
FROM INSP. 0.30 -0050 -06 +00 OK BAD
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
STATION NO. 1
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC
120
120
2500HC
50
50
I. CO
0.80
2500CO
0.40
0.80 0.40
FAILURE COST
PASS 2.50
PASS
2.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO::.C0397
09/21/73 BAR:24.56 DB:70 WB:55
REL.HUM:40.6% NOX COR: .909
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.16
3.96
3.97
4.43
53.8
20.1
19.7
27.0
547.2
548.8
479.8
529.3
5.54
4.36
5.94
5.05
13.67
15.02
17.02
15.20
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2747
3523
3740
0.37
0.23
0.81
233
2387
3327
324
420
435
190
240
260
100
0.45
0.25
0.85
0.45
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0397
09/21/73 BAR
REL.HUM:
:24.56
40.6%
DB: 70
NOX COR
WB: 55
: .909
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.16
3.96
3.97
4.43
53.8
20. 1
19.7
27.0
547.2
548.8
479.8
529.3
5.54
4.36
5.94
5.05
13.67
15.02
17.02
15.20
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2747
3523
3740
0.37
0.23
0.81
233
2387
3327
324
420
435
190
240
260
100
0.45
0. 25
0.85
0.45
AUTOMOTIVE
TESTING LABORATORIES,INC.
19900 E,
-------
*** COLORADO-393 ***
VEHICLE 162
1964 CHEV STAW 283 4000LBS
8CYL 4BBL AUTOMATIC 074643 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
============================= MAINTENANCE STATUS ==============================
I. CO I.RPM TIM DWL PCV A.CL CHOKE A. PMP MISF. NOXC
FROM OWNER 7.40 40110 +00 -K)0 NA BAD OK NA NO NA
FROM INSP. 1.40 -0025 +06 -01 NA BAD OK NA NO NA
— IDLE INSPECTION
STATION NO. 8
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
780
800
460
460
2500HC
480
580
380
380
I. CO
9.40
3.00
3.00
2500CO
8.00
8.80
6.00
6.00
FAILURE
BOTH
BOTH
PASS
PASS
COST
3.50
2.00
2.50
8.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0399
09/21/73 BAR:24.62 DB:77 WB:56
REL.HUM:27.9% NOX COR: .882
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
16.12
15.01
10.84
14.09
184.0
223.7
176.7
202.4
417.4
389.4
335.6
380.3
1.41
0. 79
0.91
0.95
11.75
11.29
13.75
11.99
12982
5711
5471
9.70
5.51
7.04
38
435
381
1042
645
579
710
460
390
510
7.90
4.80
7.10
8.00
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0412
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
09/22/73 BAR: 24.78 DB:74 WB:56
REL.HUM:33.9% NOX COR: .898
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
12.99
7.38
7.03
8.45
142.0
124.0
128.8
129. 1
420.2
405.4
361.4
396.3
1.60
0.91
1.14
1.12
13.01
14.28
15.20
14.23
5316
5128
4894
2.08
4.90
6.89
96
478
385
742
654
563
500
515
440
500
1.70
4.40
7.20
6.60
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 163
1972 DATS STAW 97 2500LBS
4CYL 1BBL 4 SPEED 024888 MILES
IDLE INSPECTION ONLY
HAS: EMC, EVC, NO PCV
======================= MAINTENANCE STATUS
I.CO I.RPM TIM DWL
FROM OWNER 3.00 -0200 -03 +11
FROM INSP. 3.00 -0100 +00 +00
PCV A.CL CHOKE A.PMP MISF. NOXC
NA OK OK NA NO NA
NA OK OK NA NO NA
IDLE INSPECTION
STATION NO. 5
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
360
300
300
2500HC
150
140
140
I. CO
2.60
1.70
1.70
2500CO
1.30
1.20
1.20
FAILURE
HC
PASS
PASS
COST
5.50
12.50
18.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO::.C0431
09/25/73 BAR:24.48 DB:70 WB:53
REL.HUM:34.0% NOX COR: .877
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.21
5.05
4.22
5.06
56.5
43.6
40.2
45.4
311.3
312.8
264.3
299.0
3. 12
2.91
3.22
3.04
21.21
22.42
26.13
23.06
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
4577
3402
2951
3.48
1.75
0.91
52
1585
2657
502
451
410
355
260
175
2500 RPM
310
3. 10
1.50
0.85
2.70
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0454
09/27/73 BAR:25.06 DB:76 WB:54
REL.HUM:23.9% NOX COR: .851
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5. 13
4.78
3.27
4.43
49.3
41.9
31.1
40.4
321.3
337.0
278.9
317.6
3.21
2.96
3.45
3. 14
21.46
21.31
26.34
22.54
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4593
3543
3065
3. 19
1. 19
0.67
67
2703
3343
660
557
476
295
200
150
250
3. 10
1. 15
0.65
2. 10
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 165
1964 PONT CATA 389 4000LBS
8CYL 2BBL AUTOMATIC 054195 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
============================== MAINTENANCE STATUS =============================
FROM OWNER
FROM INSP.
I. CO I.RPM
2.10 +0070
1.30 +0095
TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
+08 +02 OK • BAD OK NA YES NA
+02 -03 OK OK OK NA NO NA
— IDLE INSPECTION
STATION NO.
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
1250
1300
4.10
*****
BOTH
2.50
AFTER I.RPM ADJUST
1275
1300
4.20
7.30
BOTH
2.50
AFTER I.MX/TM ADJ1
800
1300
3.20
7.30
BOTH
2.50
AFTER I.MX/TM ADJ2
400
320
4.00
3.20
PASS
2.50
REPAIRS
43.95
FINAL INSPECTION
400
320
4.00
3.20
PASS
***************************
TEST NO:C0398
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
53.95 TOT.
AS RECEIVED FROM OWNER ***************************
09/21/73 BAR:24.59 DB:72 WB:54
REL.HUM:32.5% NOX COR: .879
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
20.21
9.03
5.60
10.42
110.7
77.0
77.7
84.3
498.3
509.4
427.4
484.3
4.02
3.77
3.88
3.86
12.10
13.51
15.70
13.71
5651
3490
3506
3.29
1.58
4.43
69
2198
1458
733
454
412
450
230
225
160
2.30
1.60
4.40
3.40
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0417
09/24/73 BAR:24.55 DB:70 WB:57
REL.HUM:47.4% NOX COR: .946
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.64
5.66
4.59
5.78
110.4
87.8
80.9
90.6
538.6
553.6
466.6
526.3
5.79
4.84
5.22
5.15
12.10
12.55
14.64
12.97
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4576
3794
3838
1.58
1.43
4.26
132
2400
1650
601
528
487
255
270
240
250
1.30
1. 40
4. 10
2.80
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 166
1970 VOLK SEDA 97 2 000LBS
4CYL 1BBL 4 SPEED 012474 MILES
SEA LEVEL RETROFIT
HAS: EMC, NO EVC, NO PCV
============================== MAINTENANCE STATUS
I. CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 4.20 -0060 +05 +00 NA OK OK NA NO NA
FROM INSP. 7.40 -0100 +05 +00 NA OK OK NA NO NA
IDLE INSPECTION
STATION NO. 4
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
0
220
220
2500RC
95
90
90
I. CO
0.00
1.80
1.80
2500CO
0.60
0.60
0.60
FAILURE
BOTH
PASS
PASS
COST
5.00
1.00
6.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0413
09/24/73 BAR:24.49 DB:72 WB:54
REL.HUM:32.5% NOX COR: .881
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.35
6.21
5.28
5.77
76.4
63.6
69.0
67.8
301. 3
339. 3
255.4
308. 1
2.64
1.87
2.24
2.14
20.32
19.40
23.41
20.58
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
8898
2754
2993
4.45
1.61
3.06
51
1172
2276
745
265
307
200
205
210
2500 RPM
180
4.50
1.75
3. 10
1.60
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0438
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
09/25/73 BAR:24.48 DB:69 WB:52
REL.HUM:33.2% NOX COR: .867
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
8.18
7.71
6.48
7.47
102.2
76.9
82. 1
83.6
286.7
290.9
247. 3
277.9
2.25
1.59
1.84
1.80
18.82
20.42
22.44
20.57
16800
3700
3629
8.50
2.00
3.96
35
1142
1954
2014
461
471
****
310
280
360
8.60
2.00
4.00
3.00
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 168
1966 VOLK SEDA 78 2000LBS
4CYL 1BBL 4 SPEED 048575 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, NO PCV
II
II
II
II
II
II
II
II
II
II
II
II
II
II
1!
ii
ii
ii
========
'== MAINTENANCE STATUS
=====
I. CO
I.RPM
TIM DWL
PCV
A,
.CL i
FROM OWNER 9.30
+0465
+10 +00
NA
OK
FROM INSP. 4.30
40325
402 +00
NA
OK
IDLE INSPECTION
—
STATION NO. 5
I.HC
2500HC
I. CO
2500CO
INITIAL INSPECTION
580
260
8.00
6.00
AFTER I.RPM ADJUST
1200
280
6.60
6.00
AFTER I.MX/TM ADJ1
280
220
3.00
4. 20
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
280
220
3.00
4.20
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
FAILURE
CO
BOTH
PASS
PASS
COST
5.50
5.50
5.50
16.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0415
09/24/73 BAR:24.51 DB : 70 WB:57
REL.HUM:47.5% NOX COR: .947
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
8.37
12.27
8. 16
10.31
102.9
130.5
99.9
116.2
246.6
251.5
233.3
245.4
3.33
1.59
2.61
2.23
20.48
17.98
21.40
19.34
13235
4488
3831
10.37
5.37
4.15
26
1365
2286
1039
501
400
860
380
290
420
9.20
5.20
4.00
7.60
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0437
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
09/25/73 BAR:24.48 DB:70 WB:52
REL.HUM:30.8% NOX COR: .862
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
7.22
8.25
5.42
7.25
88.3
94.1
78.4
88.5
248.1
236.0
205.8
230.2
2.83
1.46
2. 10
1.92
21.73
21.72
25.72
22.71
5467
4428
3633
4.92
6.54
3.96
56
635
2526
504
508
445
365
335
260
340
4.90
6.20
3-80
5.50
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 169
1965 PLYM FURY 318 4000LBS
8CYL 2BBL AUTOMATIC 113497 MILES
SEA LEVEL RETROFIT
HAS: EMC, NO EVC, PCV
MAINTENANCE STATUS ============================
I. CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 7.60 40045 +08 -02 OK BAD OK NA NO NA
FROM INSP. 6.10 +0100 +08 -02 OK BAD OK NA NO NA
IDLE INSPECTION
STATION NO. 3
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
550
700
650
650
2500HC
300
350
500
500
I. CO
3.50
6.00
1.00
1.00
25O0CO
8.50
6.50
1.00
1.00
FAILURE
BOTH
CO
PASS
PASS
COST
0.00
0.00
0.00
12.00
12.00 TOT.
***************************
TEST NO:C0414
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
AS RECEIVED FROM OWNER ***************************
09/24/73 BAR:24.49 DB:72 WB:54
REL.HUM:32.5% NOX COR: .881
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
23.66
15.34
11.03
15.88
289.3
236.1
227.2
244.8
407.1
354. 1
340.1
361.3
1.06
0.71
0.84
0.82
9.51
11.51
12. 17
11.19
10085
5906
4867
8.86
9.76
7.74
22
161
364
940
672
530
860
475
420
560
8.20
9. 10
8.00
4.80
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0430
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
09/25/73 BAR:24.49 DB:70 WB:51
REL.HUM:27.7% NOX COR: .847
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
17.12
11.10
8.61
11.67
258.3
204.5
207.6
216.6
375.3
365.2
328.9
357.3
1.01
0.87
0.82
0.88
10.66
12.34
13.05
12.13
6087
5802
5046
6.91
9.22
7.76
58
208
389
786
773
666
485
460
355
370
6.20
8.60
7.50
3.90
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 170
1966 FORD MUST 289 3000LBS
8CYL 2BBL AUTOMATIC 081058 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
=====
========
========
=======
== MAINTENANCE STATUS
I. CO
I.RPM
TIM DWL PCV A,
.CL
FROM
OWNER
8.50
+0000
+01 +00 OK
OK
FROM
INSP.
2.70
+0000
+00 +00 OK
OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDDE INSPECTION
STATION NO.
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
460
500
8.10
2.30
BOTH
2.50
AFTER I.RPM ADJUST
480
420
8.20
2.30
BOTH
2.50
AFTER I.MX/TM ADJ1
320
380
2.20
2.20
PASS
2.50
AFTER I.MX/TM ADJ2
0
0
0.00
0.00
NO ANS.
2.50
REPAIRS
FINAL INSPECTION
320
380
2.10
2. 10
PASS
10.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0432
09/25/73 BAR:24.49 DB:70 WB:53
REL.HUM:34.0% NOX COR: .877
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
12.59
11.54
8.13
10.81
152. 1
151.3
87.0
133.6
403.2
399.7
379.2
394.7
1.87
1.60
2.78
1.98
13.06
13.21
16.44
13.94
8852
4350
3940
9.69
2.00
2.24
27
1308
1789
724
542
476
540
390
300
700
9. 10
2. 10
2.20
4.20
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0452
09/26/73 BAR:24.88 DB:69 WB:52
REL.HUM:32.8% NOX COR: .863
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
9.95
6.82
5.21
7.03
135.2
101.7
60. 6
97.3
390.5
424.5
374.3
403.5
1.93
2.00
3.01
2.27
14.04
14.70
18.32
15.39
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4062
4308
3977
3.12
1.45
1.63
83
1316
2561
529
618
556
325
365
285
500
3.00
1.55
1.80
2. 20
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 171
1965 FORD STAW 289 4500LBS
8CYL 2BBL AUTOMATIC 071092 MILES
SEA LEVEL RETROFIT
HAS: NO EMC, NO EVC, PCV
FROM. OWNER
FROM INSP.
I.CO I.RPM
4.80 +0020
0.50 +0100
TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
-03 +03 OK OK OK NA NO NA
-03 +04 OK OK OK NA NO NA
IDLE INSPECTION
STATION NO. 8
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
480
420
420
2500HC
400
420
420
I. CO
7.40
1.90
2500CO
5.00
1.90 4.00
4.00
FAILURE
CO
PASS
PASS
COST
3.50
2.50
6.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0427
09/25/73 BAR:24.48 DB:72 WB:56
REL.HUM:38.8% NOX COR: .915
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
17.03
13.84
10.72
13.64
190.7
155.8
132.6
156.7
486. 1
477.8
450.2
471.9
2. 11
1.99
2.54
2.17
10-61
11.62
12.86
11.70
6219
5411
5347
4.83
3.61
6.46
72
1000
445
844
768
704
770
600
470
520
4.00
3.70
6.50
4. 60
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0440
09/26/73 BAR:24.78 DB:72 WB:59
REL.HUM:48.6% NOX COR: .970
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
17.93
15.58
9.63
14.42
222.3
194.4
117.5
178.9
573.8
611.3
466.1
563.1
3.02
2.68
2.96
2.83
9.09
9.22
13.07
10.01
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
5511
5381
4722
0.58
2.82
2.97
108
1277
1353
766
706
578
740
660
480
560
0.60
2.70
2.90
4. 30
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 172
1964 CHEV IMPA 283 3500LBS
8CYL 2BBL AUTOMATIC 110629 MILES
SEA LEVEL RETROFIT
HAS: NO EMC, NO EVC, PCV
FROM OWNER
FROM INSP.
*== MAINTENANCE STATUS
I. CO I.RPM TIM DWL PCV A.CL
3.20 +0290 +12 -06 NA BAD
6.10 +0030 +02 +00 NA BAD
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
STATION NO. 2
IDLE INSPECTION
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
720
840
4.60
10.00
BOTH
0.00
AFTER I.RPM ADJUST
640
840
1.80
10.00
BOTH
0.00
AFTER I.MX/TM ADJ1
640
700
6.00
10.00
CO
0.00
AFTER I.MX/TM ADJ2
880
880
6.80
10.00
BOTH
0.00
REPAIRS
15.40
FINAL INSPECTION
880
880
6.80
10.00
BOTH
90.00
15.40 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0428
09/25/73 BAR:24.58 DB:72 WB:51
REL.HUM:23.5% NOX COR: .835
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
17.08
14.01
11.81
14.04
201.6
210.2
174.2
198.4
354.4
334.9
309.4
331.9
1.37
0 • 66
1. 11
0.93
12.28
12.55
14.35
12.95
6684
6724
5890
3.91
7.34
6.08
127
414
833
847
807
717
670
680
540
1000
3.30
7.40
6.00
9.00
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* as RECEIVED FROM INSPECTION ************************
TEST NO:C0441
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
09/26/73 BAR:24.78 DB:72 WB:56
REL.HUM:38.6% NOX COR: .911
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
17.05
18.65
12.07
16.49
212.8
243.7
184.8
220.9
335.5
304.5
291.6
307.4
0.77
0.35
0.65
0.52
12.30
11.93
14.36
12.61
11071
6520
5600
8.39
8.10
6.39
31
196
503
1038
771
662
920
785
550
920
6.10
8.20
6.30
9.60
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 173
1972 OLDS CUTL 350 3500LBS
8CYL 2BBL AUTOMATIC 026639 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, EVC, PCV
============================== MAINTENANCE STATUS ===
FROM OWNER
FROM INSP.
I.CO I.RPM
4.30 +0150
4.30 +0150
TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
-05 -06 OK BAD OK NA NO NA
-05 -06 OK BAD OK NA NO NA
STATION NO. 10
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC
130
130
2500HC
60
60
I. CO
3.20
2500CO
2.30
3.20 2.30
FAILURE COST
PASS 1.50
PASS
1.50 TOT.
***************************
AS ]
RECEIVED :
FROM OWNER
***************************
TEST NO.: C0429
09/25/73 BAR:24.48
DB: 70
WB:51
REL.HUM:27.7%
NOX COR
: .847
HC
CO
CO 2
NOX
MPG LHC
SHC
SCO
COLD TRANSIENT
6.94
117. 1
580.4
3.46
11.33
COLD STABILIZED
5.54
133.2
538.5
1.36
11.64
HOT TRANSIENT
4.54
87.4
485.1
2.97
13.99
1975 COMPOSITE
5.56
117. 1
532.5
2.25
12. 14
IDLE KEYMODE
3787
4.52
72
536
220
4.50
LOW CR. KEYMODE
4080
3.55
695
591
310
3.50
HI. CR. KEYMODE
3301
1.19
2326
468
190
1.20
2500 RPM
130
3.80
*************************
TEST NO:C0429
AS RECEIVED FROM INSPECTION ************************
09/25/73 BAR:24.48 DB:70 WB:51
REL.HUM:27.7% NOX COR: .847
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.94
5.54
4.54
5.56
117. 1
133.2
87.4
117. 1
580.4
538.5
485.1
532.5
3.46
1.36
2.97
2.25
11.33
11.64
13.99
12.14
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3787
4080
3301
4.52
3.55
1.19
72
695
2326
536
591
468
220
310
190
130
4.50
3.50
1. 20
3.80
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 174
1969 FORD FAIR 302 3500LBS
8CYL 2BBL AUTOMATIC 055127 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
=====
=======
=========
========
== MAINTENANCE STATUS
sas
I. CO
I.RPM
TIM DWL PCV A
.CL
FROM
OWNER
4.00
40000
+02 +00 OK
OK
FROM
INSP.
0.14
-0050
+07 +00 OK
OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 6
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
470
430
1500
270
2500HC
270
240
820
250
I. CO
4.40
2.10
1.00
0.20
2500CO
0.50
0.40
0.50
0.40
FAILURE
BOTH
HC
HC
PASS
COST
4.50
1.50
3.00
9.00 TOT.
'k'k'k&Jejt'k&TkJc&'k'kJe&icJeJc'kikjcjc'kJejcik'k
TEST NO:C0442
AS RECEIVED FROM OWNER ***************************
09/26/73 BAR:24.77 DB:69 WB:53
REL.HUM:36.2% NOX COR: .880
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
9.76
7.65
6.25
7.70
122.3
80.7
66.5
85.5
507.6
572.5
501.2
539. 1
4.52
7.29
7.83
6.86
12. 19
12.31
14.24
12.76
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
5095
4491
4842
4.45
0.42
4.02
95
4463
1397
675
642
639
520
420
435
2500 RPM
235
4.20
0.45
4. 20
0.80
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0464
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
09/27/73 BAR:24.99 DB:70 WB:54
REL.HUM:36.9% NOX COR: .887
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
8.74
5.34
6.70
6.43
173.9
68.6
64.5
89.5
526.4
551.5
545.5
544.6
1.96
3.83
4.40
3.60
10.76
13.17
13.33
12.62
1761
4067
4480
0.17
0.42
7.27
101
2598
292
425
684
630
125
330
275
125
0.20
0.30
7.10
0.70
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 175
1972 CHEV NOVA 350 3500LBS
8CYL 2BBL AUTOMATIC 021117 MILES
TUNE UP EVALUATION
HAS: EMC, NO EVC, PCV
============================= MAINTENANCE STATUS ===
I.CO I.RFM TIM DWL PCV A.CL
FROM OWNER 2.80 -0010 +00 +01 OK BAD
FROM INSP. 2.80 -0010 +00 +01 OK BAD
CHOKE A.PMP MISF. NOXC
OK OK NO NA
OK OK NO NA
IDLE INSPECTION
STATION NO. 1
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
130
130
2500HC
60
60
I.CO 25O0CO
2.80 1.80
2.80 1.80
FAILURE COST
PASS 2.50
PASS
2.50 TOT.
***************************
TEST NO:C0443
AS RECEIVED FROM OWNER ***************************
09/26/73 BAR:24.77 DB:70 WB:53
REL.HUM:33.8% NOX COR: .874
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
6.90
94.9
555.9
3.72
12.25
COLD STABILIZED
4.96
65.7
546.3
2.40
13.39
HOT TRANSIENT
4.63
59.8
477.1
3.87
15.20
1975 COMPOSITE
5.28
70.2
529.1
3.08
13.58
IDLE KEYMODE
4411
2.94
101
556
395
3.00
LOW CR. KEYMODE
4106
2.01
1699
541
350
2.60
HI. CR. KEYMODE
3577
0.98
2638
483
2 70
1. 15
2500 RPM
185
2.60
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0443
09/26/73 BAR:24.77 DB:70 WB:53
REL.HUM:33.8% NOX COR: .874
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.90
4.96
4.63
5.28
94.9
65.7
59.8
70.2
555.9
546.3
477.1
529.1
3.72
2.40
3.87
3.08
12.25
13.39
15.20
13.58
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4411
4106
3577
2.94
2.01
0.98
101
1699
2638
556
541
483
395
350
270
185
3.00
2.60
1. 15
2.60
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 176
1973 CADI DEVI 472 5000LBS
8CYL 4BBL AUTOMATIC 007405 MILES
IDLE INSPECTION ONLY
HAS: EMC, EVC, PCV
============================== MAINTENANCE STATUS ==============================
FROM OWNER
FRCM INSP.
I.CO I.RPM
1.50 +0000
1.50 +0000
TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
+00 +09 OK BAD OK OK NO OK
+00 +09 OK BAD OK OK NO OK
IDLE INSPECTION
STATION NO. 8
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
60
60
2500HC
40
40
I. CO
1.20
2500CO
0.25
1.20 0.25
FAILURE COST
PASS 3.50
PASS
3.50 TOT.
***************************
TEST NO:C0444
AS RECEIVED FROM OWNER ***************************
09/26/73 BAR:24.77 DB:69 WB:53
REL.HUM:36.2% NOX COR: .880
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
5.73
112.0
837.3
1.62
8.63
COLD STABILIZED
2.53
69.7
887.5
1.70
8.86
HOT TRANSIENT
2.29
77.5
755.6
1.77
10.07
1975 COMPOSITE
3.13
80.7
840.4
1.70
9. 12
IDLE KEYMODE
1371
1.69
74
312
110
1.60
LOW CR. KEYMODE
2174
1.97
1227
419
150
1.70
HI. CR. KEYMODE
1517
1.08
1162
368
110
0.90
2500 RPM
70
0.40
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0444
09/26/73 BAR:24.77 DB:69 WB:53
REL.HUM:36.2% NOX COR: .880
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.73
2.53
2.29
3.13
112.0
69.7
77.5
80.7
837.3
887.5
755.6
840.4
1.62
1.70
1.77
1.70
8.63
8.86
10.07
9. 12
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
1371
2174
1517
1.69
1.97
1.08
74
1227
1162
312
419
368
110
150
110
70
1.60
1.70
0.90
0.40
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 177
1972 CHRY NEWP 400 4500LBS
8CYL 2BBL AUTOMATIC 029493 MILES
IDLE INSPECTION ONLY
HAS: EMC, EVC, PCV
FROM OWNER
FROM INSP.
I.CO I.RPM
9.10 +0180
1.10 +0120
MAINTENANCE STATUS =========.==================.===
TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
-02 +10 OK OK OK NA NO NA
-10 +08 OK OK OK NA NO NA
STATION NO.
IDLE INSPECTION
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
1350
500
*****
*****
BOTH
0.00
AFTER I.RPM ADJUST
1300
550
*****
*****
BOTH
0.00
AFTER I.MX/TM ADJ1
1300
550
*****
*****
BOTH
0.00
AFTER I.MX/TM ADJ2
0
0
0.00
0.00
NO ANS.
12.00
REPAIRS
33.95
FINAL INSPECTION
150
60
2.60
2.00
PASS
45.95 TOT.
*************************** as RECEIVED FROM OWNER ***************************
TEST NO:C0445
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
09/26/73 BAR:24.77 DB:70 WB:56
REL.HUM:43.8% NOX COR: .924
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
27.89
48.60
21.07
36.63
265.8
394. 3
230.8
322. 1
453.2
423.6
415. 9
427. 7
1.28
0.51
1.50
0.95
9.28
7.44
10.53
8.49
12878
5268
4088
11.37
7.72
5.63
20
270
771
1037
722
568
730
415
270
****
9.50
7.80
5.60
*****
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO.-C0480
09/28/73 BAR:24.83 DB:70 WB:54
REL.HUM:37.0% NOX COR: .889
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.66
4.21
4.54
5.02
129.2
55.1
68.6
74.3
567. 2
586.4
501.9
558.9
3. 14
2.36
3.55
2.85
11.21
12.98
14.27
12.88
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3036
3081
3239
1. 20
0.38
2.30
73
1861
2206
313
353
344
120
180
115
65
1.25
0.40
2.40
0.90
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 178
1964 FORD GALA 390 4000LBS
8CYL 4BBL AUTOMATIC 059024 MILES
SEA LEVEL RETROFIT
HAS: NO EMC, NO EVC, PCV
============================== MAINTENANCE STATUS =»=¦=
I.CO I.RPM TIM DWL PCV A.CL
FROM OWNER 7.00 -0100 -02 +00 NA OK
FROM INSP. 7.00 -0100 -02 -K)0 NA OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 10
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
450
450
2500HC
150
150
I. CO
6.00
6.00
2500CO
2.00
2.00
FAILURE
PASS
PASS
COST
1.50
1.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0453
09/26/73 BAR:24.91 DB:70 WB:53
REL.HUM:33.7% NOX COR: .872
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
17.19
13.95
9.71
13.45
131.5
135.5
91.2
122.4
572.7
519.5
489.1
522.2
3.00
2.51
2.76
2.68
10.68
11.47
13.43
11.76
8486
5536
5159
8.03
2.81
1.96
78
941
1922
1465
787
674
1100
490
380
260
7.20
2.80
2. 10
3.10
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0453
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
09/26/73 BAR:24.91 DB:70 WB:53
REL.HUM:33.7% NOX COR: .872
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
17.19
13.95
9.71
13.45
131.5
135.5
91.2
122.4
572.7
519.5
489.1
522.2
3.00
2.51
2. 76
2.68
10.68
11.47
13.43
11.76
8486
5536
5159
8.03
2.81
1.96
78
941
1922
1465
787
674
1100
490
380
260
7.20
2.80
2. 10
3. 10
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 179
1973 CHEV NOVA 307 3500LBS
8CYL 2BBL AUTOMATIC 017115 MILES
TUNE UP EVALUATION
HAS: EMC, EVC, PCV
============================== MAINTENANCE STATUS
I.CO I.RPM TIM DWL PCV A.CL
FROM OWNER 1.16 -0200 +00 +01 OK OK
FROM INSP. 1.16 -0200 +00 -K)l OK OK
CHOKE A.PMP MISF. NOXC
OK NA NO OK
OK NA NO OK
IDLE INSPECTION
STATION NO. 1
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
70
70
2500HC
30
30
I. CO
0.60
0.60
2500CO
0.30
0.30
FAILURE
PASS
PASS
COST
0.00
2.50
2.50 TOT.
***************************
TEST NO:C0708
AS RECEIVED FROM OWNER ***************************
10/22/73 BAR:24.73 DB:70 WB:51
REL.HUM:27.4% NOX COR: .845
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.08
2.50
2.49
2.83
84.8
56.7
67.7
65.6
599.2
562.6
471.6
545.0
1.91
1.32
1.44
1.48
11.95
13.50
15.20
13.56
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
898
1919
1319
1.62
2.21
2.67
49
546
556
197
303
266
20
40
30
20
0.37
0.50
0.65
0. 15
************************* as RECEIVED FROM INSPECTION ************************
TEST"NO:CO708
10/22/73 BAR:24.73 DB:70 WB:51
REL.HUM:27.4% NOX COR: .845
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.08
2.50
2.49
2.83
84.8
56.7
67.7
65.6
599.2
562.6
471.6
545.0
1.91
1.32
1.44
1.48
11.95
13.50
15.20
13.56
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 kPM
898
1919
1319
1.62
2.21
2.67
49
546
556
197
303
266
20
40
30
20
0.37
0.50
0.65
0. 15
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 180
1968 FORD GALA 302 4000LBS
8CYL 2BBL AUTOMATIC 076747 MILES
TUNE UP EVALUATION
HAS: EMC, NO EVC, PCV
FROM OWNER
FROM INSP.
I. CO
6.70
5.50
•========= MAINTENANCE STATUS ===========
I.RPM TIM DWL PCV A.CL CHOKE
-0020 +04 +00 OK OK OK
-0050 +04 +00 OK OK OK
A.PMP MISF. NOXC
NA NO NA
NA NO NA
IDLE INSPECTION
STATION NO. 6
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
****
2000
5.40
0.60
BOTH
4.50
AFTER I.RPM ADJUST
****
****
3.60
0.50
BOTH
1.50
AFTER I.MX/TM ADJ1
****
****
2.40
0.50
HC
1.50
AFTER I.MX/TM ADJ2
****
****
1.10
0.30
NO ANS.
3.00
REPAIRS
26.07
FINAL INSPECTION
230
1600
1.50
0.50
HC
30.00
36.57 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0456
09/27/73 BAR:25.06 DB:74 WB:53
REL.HUM:24.9% NOX COR: .848
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
8.89
5.66
5.60
6.32
90.5
66.7
57.2
69.1
585.8
535.0
488.1
532.6
7.19
6.09
7.55
6.73
11.78
13.54
14.95
13.47
6014
3294
3960
7.17
0.42
5.67
64
3619
861
791
591
616
550
235
265
****
7.20
0.55
5.40
1.10
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0475
09/28/73 BAR:24.84 DB:70 WB:56
REL.HUM:43.8% NOX COR: .923
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.18
4.16
4.45
4.87
94.8
52.7
53.4
61.7
603.5
555.4
496.6
549.2
5.56
4.53
5.61
5.04
11.49
13.67
14.98
13.46
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4473
2831
2875
5.82
0.32
1.57
66
2463
2403
543
386
387
320
160
150
270
6.00
0.40
1.60
0.80
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 181
1968 CHEV NOVA 307 3000LBS
8CYL 2BBL AUTOMATIC 042449 MILES
TUNE UP EVALUATION
HAS: EMC, NO EVC, PCV
==== MAINTENANCE STATUS
FROM OWNER
FROM INSP.
I. CO
6.80
1.80
I.RPM
-0060
+0000
TIM DWL
408 -05
+08 -05
PCV
OK
OK
A.CL
OK
OK
CHOKE A.PMP MISF. NOXC
OK NA ' NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 8
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
500
270
5.00
3.20
BOTH
0.00
680
300
6.00
2.80
BOTH
0.00
450
250
6.00
2.50
BOTH
0.00
300
200
1.60
1.50
PASS
0.00
10.50
300
200
1.60
1.50
PASS
10.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0457
09/27/73 BAR:25.06 DB:70 WB:54
REL.HUM:36.8% NOX COR: .886
SCO
HC
CO
CO 2
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT ' TRANSIENT
1975 COMPOSITE
8.27
7.34
5.60
7.05
108.6
96.2
72.7
92.3
431.6
403.1
366.9
399.0
3.45
2.69
3.48
3.07
14.17
15.42
17.85
15.73
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
6918
4425
4354
7.35
2.29
2.99
65
1765
1959
1109
755
704
740
390
330
2500 RPM
340
7.00
2.50
3.00
2.50
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:CA475
09/28/73 BAR:24.85 DB:71 WB:56
REL.HUM:41.1% NOX COR: .917
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.19
4.72
5.52
5.25
100.0
46.6
72.7
65.0
432.2
444.1
368.2
420.6
2.61
2.37
3.59
2.76
14.62
16.73
17.81
16.51
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4765
4786
4313
3.06
2. 14
2.55
899
215
1414
0
639
582
420
350
270
210
2.20
2.70
3.50
2.40
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 182
1968 CHEV CAME 327 3500LBS
8CYL 2BBL AUTOMATIC 083926 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
==j==:3=========x=======::3in:3«==:s= MAINTENANCE STATUS ==»========¦=================>=
I. CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF NOXC
FROM OWNER 5.90 -0160 404 +00 OK BAD OK NA NO NA
FRCM INSP. 4.60 -0300 +00 +00 OK OK OK NA NO NA
IDLE INSPECTION
STATION NO. 9
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
650
700
700
700
2500HC
320
280
260
260
I. CO
5.00
3.00
2.20
2.20
2500CO
2.50
1.50
1.50
1.50
FAILURE
BOTH
BOTH
BOTH
PASS
COST
0.00
0.00
0.00
4.00
4.00 TOT.
***************************
TEST NO:C0458
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
AS RECEIVED FROM OWNER ***************************
09/27/73 BAR:25.06 DB:70 WB:53
REL.HUM:33.5% NOX COR: .871
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
12.55
7.86
6.95
8.59
157.3
74.0
79.1
92.9
476.7
447.5
414.7
444.5
3.71
3.20
'3.90
3.50
11.66
15.12
15.87
14.42
7035
4574
4238
6.16
1.77
2.45
82
1992
2252
885
689
625
730
390
310
280
6.00
1.90
2.50
2.00
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0491
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
10/01/73 BAR:24.72 DB:79 WB:58
REL.HUM:29.4% NOX COR: .903
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
13.33
7.62
6.10
8.39
149.9
83.2
78.2
95.8
438.7
418.9
380.3
412.4
3.42
2.77
3.70
3.16
12.43
15.52
17.04
15.11
6179
4809
4321
4.77
2.87
2.94
102
1230
2050
832
665
575
790
460
340
360
4.60
3.00
3.10
3.10
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 183
1971 CHEV STAW 400 4500LBS
8CYL 2BBL AUTOMATIC 021163 MILES
TUNE UP EVALUATION
HAS: EMC, NO EVC, PCV
============================== MAINTENANCE STATUS ==============================
I.CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 2.00 -0010 400 400 OK OK OK NA NO NA
FROM INSP. 2.00 -0010 400 400 OK OK OK NA NO NA
STATION NO.
1
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
70
70
2500HC
20
20
I.CO 2500CO
2.00 0.50
2.00 0.50
FAILURE COST
PASS 2.50
PASS
2.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0459
09/27/73 BAR:25.05 DB:70 WB:53
REL.HUM:33.5% NOX COR: .871
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
10.79
4.33
4.41
5.70
230.9
72.7
92.8
111.4
626.5
701.1
579.4
651.7
2.55
2.95
3.39
2.99
8.70
10.74
12.05
10.54
3634
2701
3238
2.15
0.82
2.71
149
1529
1569
544
445
469
235
120
145
50
2. 10
0.75
2.70
0.55
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST N0:C0459
09/27/73 BAR:25.05 DB:70 WB:53
REL.HUM:33.5% NOX COR: .871
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
10.79
4.33
4.41
5.70
230.9
72.7
92.8
111.4
626.5
701.1
579.4
651.7
2.55
2.95
3.39
2.99
8.70
10.74
12.05
10.54
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3634
2701
3238
2. 15
0.82
2.71
149
1529
1569
544
445
469
235
120
145
50
2. 10
0.75
2.70
0.55
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO—393 ***
VEHICLE 184
1971 CHEV IMPA 350 4000LBS
8CYL 2BBL AUTOMATIC 035988 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
============================== MAINTENANCE STATUS =========>===»===============
FROM OWNER
FRCM INSP.
I.CO I.RPM
4.80 +0100
1.40 +0000
TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
404 -02 OK BAD OK NA NO NA
+00 +00 OK BAD OK NA NO NA
IDLE INSPECTION
STATION NO.
I. HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
300
60
7.60
0.40
BOTH
5.50
AFTER I.RPM ADJUST
300
60
7.60
0.40
BOTH
3.30
AFTER I.MX/TM ADJ1
180
35
2.20
0.20
PASS
3.30
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
180
35
2.20
0.20
PASS
12.10 TOT.
TEST NO:C0467
AS RECEIVED FROM OWNER ***************************
09/27/73 BAR:24.98 DB:70 WB:52
REL.HUM:30.4% NOX COR: .857
HC CO
COLD TRANSIENT 6.27 121.1
COLD STABILIZED 4.90 59.8
HOT TRANSIENT 4.39 64.8
1975 COMPOSITE 5.04 74.0
IDLE KEYMODE 4901 5.35
LOW CR. KEYMODE 3793 1.07
HI. CR. KEYMODE 2945 0.44
2500 RPM
CO 2
NOX
MPG
LHC
SHC
SCO
600.7
600.2
510.6
575.4
3.68
3.49
4.18
3.72
10.98
12.55
14.22
12.59
94
1548
3183
759
636
555
390
230
140
5.20
1.20
0.50
110
1.70
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0492
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
10/01/73 BAR:24.71 DB:76 WB:53
REL.HUM:21.6% NOX COR: .840
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
4.78
3.21
3.50
3.62
78.0
15.3
45.9
36.9
611.5
639.0
505.2
596.1
3.69
3.24
3.60
3.43
11.89
13.23
15. 14
13.38
3811
2289
2748
1.48
0.20
0.50
147
1046
2810
539
419
404
325
120
150
85
1.60
0.24
0.50
1.20
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 185
1971 TOYO CORO 71 2000LBS
4CYL 2BBL 4 SPEED 029881 MILES
IDLE INSPECTION ONLY
HAS: EKC, NO EVC, NO PCV
u
ii
ii
u
11
II
II
II
II
== MAINTENANCE STATUS
======
I. CO
I.RPM
TIM DWL
PCV A
.CL 1
FROM OWNER 4.10
+0210
+00 -11
NA
OK
FROM INSP. 1.16
+0010
+00 +00
NA
OK
IDLE INSPECTION -
STATION NO. 5
I.HC
2500HC
I. CO
2500CO
INITIAL INSPECTION
390
120
4.60
1.20
AFTER I.RPM ADJUST
520
130
4.40
1.20
AFTER I.MX/TM ADJ1
300
130
0.80
1.30
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
300
130
0.80
1.30
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
FAILURE
BOTH
BOTH
PASS
PASS
COST
5.50
0.00
12.50
18.00 TOT.
***************************
AS RECEIVED FROM
[ OWNER
***************************
TEST NO:C0469
09/28/73 BAR
00
00
-------
*** COLORADO-393 ***
VEHICLE 186
1970 VOLK SEDA 97 2000LBS
4CYL 1BBL 4 SPEED 048300 MILES
IDLE INSPECTION ONLY
HAS: EMC, NO EVC, NO PCV
=============*=»================ MAINTENANCE STATUS =a=:=
I.CO I.RPM TIM DWL PCV A.CL
FROM OWNER 5.10 -0100 +04 -07 NA OK
FROM INSP. 4.95 +0000 +04 +00 NA OK
CHOKE A.PMP MISF.
OK NA NO
OK NA NO
NOXC
NA
NA
— IDLE INSPECTION
STATION NO.
I.HC
2500HC
I. CO
2500C0
FAILURE
COST
INITIAL INSPECTION
1020
350
1.00
0.40
BOTH
5.00
AFTER I.RPM ADJUST
1150
300
4.50
0.60
BOTH
1.00
AFTER I.MX/TM ADJ1
1150
300
4.50
0.60
BOTH
1.00
AFTER I.MX/TM ADJ2
290
80
2.20
0.70
PASS
2.00
REPAIRS
FINAL INSPECTION
290
80
2.20
0.70
PASS
9.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0470
09/28/73 BAR:24.85 DB:70 WB:55
REL.HUM:40.3% NOX COR: .905
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.62
5.49
3.68
5.02
81.7
40; 4
40.4
49.1
292.6
328.8
276.7
306.8
3.97
3.74
4.40
3.97
20.30
21.73
25.31
22.28
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
14291
3744
3159
6.00
0.89
1.74
35
2479
: 4267
****
526
509
****
220
200
350
5.00
0.90
1.70
0.55
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0495
10/01/73 BAR:24.70 DB:74 WB:56
REL.HUM:34.0% NOX COR: .899
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.34
3.65
3.24
3.89
82.2
60.4
64.3
66.1
265.6
304.1
248.2
280.5
2.01
1.49
1.64
1.64
21.63
21.69
24.77
22.46
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
5145
2209
2353
5.56
1.32
2.06
66
933
2389
594
408
442
330
130
140
200
5.30
1.25
1.90
2.00
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** C0L0RAD0-393 ***
VEHICLE 187
1973 FORD LTD 351 4500LBS
*8CYL 2BBL AUTOMATIC 004725 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, EVC, PCV
=====
II
li
II
li
u
n
ii
ii
ii
u
ii
ii
ii
ii
========
=== MAINTENANCE STATUS
==:
I. CO
I.RPM
TIM DWL PCV A,
.CL
FROM
OWNER
0.60
-0155
+10 +00 OK
OK
FROM
INSP.
0.60
-0155
+10 +00 OK
OK
CHOKE A.PMP MISF. NOXC
OK NA, NO OK
OK NA NO OK
STATION NO. 10
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
150
150
2500HC
75
75
I. CO 2500CO
0.20 1.30
0.20 1.30
FAILURE COST
PASS 1.50
PASS
1.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0482
10/01/73 BAR:24.74 DB:70 WB:54
REL.HUM:37.1% NOX COR: .890
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
HC
6.29
4.48
3.99
4.72
CO
134.7
78.8
79.1
90.6
C02
659.0
661.6
537.5
626.6
NOX
2.09
1.92
2.00
1.98
MPG
10.00
11.14
13.21
11.36
LHC
SHC
SCO
IDLE KEYMODE
2763
0.62
184
354
140
0.70
LOW CR. KEYMODE
3607
2.18
1826
508
220
2.20
HI. CR. KEYMODE
3176
2.16
1154
451
165
2.10
2500 RPM
110
3. 10
*************************
TEST NO:C0482
AS RECEIVED FROM INSPECTION
(
************************
10/01/73 BAR:24.74 DB:70 WB:54
REL.HUM:37.1% NOX COR: .890
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.29
4.48
3.99
4.72
134.7
78.8
79.1
90.6
659.0
661.6
537.5
626.6
2.09
1.92
2.00
1.98
10.00
11.14
13.21
11.36
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2763
3607
3176
0.62
2. 18
2.16
184
1826
1154
354
508
451
140
220
165
no
0.70
2.20
2. 10
3. 10
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 188
1971 MERC COUG 351 4000LBS
8CYL 2BBL AUTOMATIC 017215 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
===¦==¦=====¦======="a==i ========== MAINTENANCE STATUS ==============================
I. CO I.RPM TIM DWL PCV A.CL CHOKE A. PMP MISF. NOXC
FROM OWNER 2.50 +0025 -+00 +02 OK OK OK NA NO NA
FROM INSP. 2.50 +0025 -H)0 +02 OK OK OK NA NO NA
IDLE INSPECTION
STATION NO. 9
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
210
210
2500HC
105
105
I. CO
1.50
1.50
2500CO
0.30
0.30
FAILURE
PASS
PASS
COST
0.00
4.00
4.00 TOT.
***************************
TEST NO:C0483
AS RECEIVED FROM OWNER ***************************
10/01/73 BAR:24.74 DB:70 WB:54
REL.HUM:37.1% NOX COR: .890
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
8.74
4.74
4.91
5.63
84. 1
54.4
48.6
59.0
591.4
611.4
537.3
586.6
5.33
4.84
6.06
5.28
11.85
12.51
14. 16
12.78
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3826
3461
3091
2.60
0.36
0.83
177
2923
3008
449
426
372
250
180
130
80
2.60
0.30
0.75
0.50
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0483
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
10/01/73 BAR:24.74 DB:70 WB:54
REL.HUM:37.1% NOX COR: .890
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
8.74
4.74
4.91
5.63
84. 1
54.4
48.6
59.0
591.4
611.4
537.3
586.6
5.33
4.84
6.06
5.28
11.85
12.51
14. 16
12.78
3826
3461
3091
2.60
0.36
0.83
177
2923
3008
449
426
372
250
180
130
80
2.60
0.30
0.75
0.50
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 189
1971 DODG DART 225 3000LBS
6CYL 1BBL AUTOMATIC 011166 MILES
IDLE INSPECTION ONLY
HAS: EMC, NO EVC, PCV
============================== MAINTENANCE STATUS ==============================
I. CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 10.28 -0255 +03 -02 BAD BAD OK NA NO NA
FROM INSP. 1.32 -0100 +03 -06 BAD BAD OK NA NO NA
IDLE INSPECTION
STATION NO. 3
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJl
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
2500HC
I. CO
2500C0
FAILURE
COST
1440
400
*****
5.00
BOTH
0.00
1050
400
*****
5.00
BOTH
0.00
300
290
1.50
3.00
PASS
0.00
12.00
300
290
1.50
3.20
PASS
12.00
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0484
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
10/01/73 BAR:24.74 DB:70 WB:54
REL.HUM:37.1% NOX COR: .890
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
18.31
21.14
14.21
18.62
209.2
232.9
194.6
217.3
326.9
280.0
273. 2
287.9
1. 14
0.59
0.89
0.79
12.48
12.49
14.27
12.94
31256
7209
5859
12.81
9.18
7.36
10
239
483
****
891
714
****
630
440
610
*****
8.60
6.50
8.00
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0512
10/02/73 BAR:24.61 DB:72 WB:54
REL.HUM:32.4% NOX COR: .879
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
10.58
7.39
6.54
7.82
203.7
161.6
163.2
170.9
353.9
326.3
303.3
325.7
1.23
0.91
1.16
1.05
12.59
14.75
15.34
14.39
5467
6005
7371
1.52
7.82
13.30
450
395
91
727
761
887
470
510
580
560
1.60
8.30
*****
7.40
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 190
1973 PLYM DUST 225 3000LBS
6CYL 1BBL AUTOMATIC 008056 MILES
IDLE INSPECTION ONLY
HAS: EMC, EVC, PCV
FROM OWNER
FRCM INSP.
=================¦ MAINTENANCE STATUS ===
I. CO I.RPM TIM DWL PCV A.CL
0.60 +0030 +01 +00 OK BAD
0.60 +0030 +01 +00 OK BAD
CHOKE A.PMP MISF. NOXC
OK OK NO OK
OK OK NO OK
IDLE INSPECTION
STATION NO. 9
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
90
90
2500HC
60
60
I. CO
0.70
0.70
2500CO
0.30
0.30
FAILURE
PASS
PASS
COST
0.00
4.00
4.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0498
10/02/73 BAR:24.67 DB:69 WB:54
REL.HUM:39.7% NOX COR: .897
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
HC
5.02
2.90
3.89
3.62
CO
96.3
33.7
49.6
51.2
C02
420.3
458.6
402.0
434.9
NOX
2.52
3.21
3.17
3.05
MPG
15.16
17.10
18.09
16.91
LHC
SHC
SCO
IDLE KEYMODE
2747
0.72
299
340
170
0.60
LOW CR. KEYMODE
2723
0.19
2095
412
165
0.18
HI. CR. KEYMODE
3908
6.19
601
543
280
6.20
2500 RPM
95
0.25
************************* AS RECEIVED FROM INSPECTION ************************
TEST N0:C0498
10/02/73 BAR:24.67 DB:69 WB:54
REL.HUM:39.7% NOX COR: .897
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.02
2.90
3.89
3.62
96.3
33.7
49.6
51.2
420.3
458.6
402.0
434.9
2.52
3.21
3.17
3.05
15.16
17.10
18.09
16.91
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2747
2723
3908
0.72
0.19
6.19
299
2095
601
340
412
543
170
165
280
95
0.60
0. 18
6.20
0.25
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 191
1967 CHEV CHE2 194 3000LBS
6CYL 1BBL 3 SPEED 022266 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
============================¦== MAINTENANCE STATUS ==============================
I. CO I.RPM TIM DWL PCV A.CL CHOKE A. PMP MISF. NOXC
FROM OWNER 6.70 +0050 -02 +00 OK OK OK NA NO NA
FRCM INSP. 7.20 +0140 +00 +00 OK OK OK NA NO NA
IDLE INSPECTION
STATION NO. 6
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
1500
520
560
560
2500HC
520
420
360
360
I. CO
*****
7.40
6.80
6.80
2500CO
3.00
3.80
3.20
3.20
FAILURE
BOTH
CO
PASS
PASS
COST
4.50
1.00
1.50
7.00 TOT.
* ** ********** ********* **** A
TEST NO:C0499
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 "COMPOSITE
AS RECEIVED FROM OUNER ***************************
10/02/73 BAR:24.67 DB:69 WB:54
REL.HUM:39.7% NOX COR: .897
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
19.08
14.67
11.88
14.82
128.2
162.6
102.8
138.8
318.4
282.3
289.3
291.8
1.84
0.81
2.02
1.36
15.34
15.24
18.23
16.00
6564
4482
5427
7.54
3.96
8.93
41
703
203
648
607
694
500
420
475
720
6.90
4.00
8. 10
6. 60
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0527
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
10/03/73 BAR:24.81 DB:69 WB:56
REL.HUM:46.6% NOX COR: .930
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
19.26
14. 13
11.02
14.34
146.0
170.3
119.7
151.2
329.8
311.8
276.3
305.7
1.81
1.14
1.50
1.38
14.36
14.27
17.84
15.13
6389
4656
5366
8.11
2.79
9.15
50
1606
178
776
760
842
320
300
330
285
7.60
3.00
2.40
4. 10
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 192
1966 CHEV CHEV 230 3500LBS
6CYL 1BBL AUTOMATIC 046973 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
==»=============¦=============== MAINTENANCE STATUS =======•=======================
I. CO . I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 4.00 +0085 +02 +00 OK BAD OK NA NO NA
FROM INSP. 1.60 +0045 +00 +00 OK BAD OK NA NO NA
IDLE INSPECTION
STATION NO. 1
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
450
440
340
340
2500HC
240
240
250
250
I.CO
7.00
8.00
4.60
4.60
2500CO
3.40
3. 20
3.20
3.20
FAILURE
CO
CO
PASS
PASS
COST
2.50
2.00
3.00
7.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0497
10/02/73 BAR:24.67 DB:69 WB:54
REL.HUM:39.7% NOX COR: .897
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
9.60
7.77
6.53
7.81
131.4
116.0
93.6
113.0
366.7
335.8
315.6
336.7
2.47
1.68
2.84
2.17
14.76
16.41
18.43
16.53
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
6803
4049
4612
6.18
0.89
5.54
51
2486
876
862
496
546
480
320
365
2500 RPM
*************************
TEST NO:C0528
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
270
4.00
0.80
5.30
1.60
AS RECEIVED FROM INSPECTION ************************
10/03/73 BAR:24.85 DB:69 WB:57
REL.HUM:50.2% NOX COR: .949
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
11.93
9.08
6.85
9.06
151.0
117.1
102.2
120.0
359.2
331.4
328.3
336.3
2.24
1.73
2.86
2. 15
14.04
16.37
17.44
16.09
5177
4102
5573
2.89
0.46
8.61
52
2459
314
1049
796
883
180
235
330
160
1.70
0.55
9.00
1.30
AUTOMOTIVE TESTING LABORATORIES.INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 193
1969 FORD FAIR 302 3500LBS
8CYL 2BBL 3 SPEED 054596 MILES
TUNE UP EVALUATION
HAS: EMC, NO EVC, PCV
===========.=================== MAINTENANCE STATUS ==============================
I.CO I.RPM TIM DWL PCV A.CL CHOKE
FROM OWNER 3.10 +0090 +04 +00 OK OK OK
FROM INSP. 1.60 -0110 -07 -K)l OK OK OK
A.PMP MISF. NOXC
NA NO NA
NA YES NA
IDLE INSPECTION
STATION NO. 7
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
420
300
200
200
2500HC
300
220
200
200
I. CO
4.10
5.10
1.40
1.40
2500CO
5.20
2. 10
1.40
1.40
FAILURE
BOTH
CO
PASS
PASS
COST
2.50
2.50
2.50
10.00
17.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0481
10/01/73 BAR:24.74 DB:71 WB:54
REL.HUM:34.6% NOX COR: .884
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
9.64
75.2
444.6
4.41
15.01
COLD STABILIZED
7.12
89.3
480.9
3.28 '
13.83
HOT TRANSIENT
6.11
49.5
412.5
4.71
17.48
1975 COMPOSITE
7.37
75.3
454.3
3.91
14.95
IDLE KEYMODE
3400
3.38
78
346
150
3.10
LOW CR. KEYMODE
4378
0.82
2386
602
300
0.80'
HI. CR. KEYMODE
4199
0.90
3346
538
240
0.70
2500 RPM
130
1.60
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0507
10/02/73 BAR:24.63 DB:78 WB:53
REL.HUM:18.4% NOX COR: .830
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
8.51
5.14
6.05
6.10
74.4
57.8
58.1
61.4
400.4
444.8
346.5
408.3
3. 17
2.38
3.07
2.74
16.36
16.13
19.49
17.00
2145
4114
3978
0.18
0.97
0.45
78
2170
3570
318
596
613
160
355
350
190
0.25
1.10
0.49
1.25
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 194
1968 CHEV IMPA 327 4000LBS HIGH ALTITUDE RETROFIT
8CYL 4BBL AUTOMATIC 054000 MILES HAS: EMC, NO EVC, PCV
=========.====«=.=.===.=========,= MAINTENANCE STATUS ====.==>=======.======»=========.
I. CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FRCM OWNER 7.50 -0020 +07 +00 OK OK OK NA NO NA
FROM INSP. 3.30 +0020 +01 +00 OK OK OK NA NO NA
IDLE INSPECTION
STATION NO. 2
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
640
760
6.40
*****
BOTH
5.50
AFTER I.RPM ADJUST
420
700
6.00
*****
BOTH
3.30
AFTER I.MX/TM ADJ1
230
600
1.00
9.90
BOTH
3.30
AFTER I.MX/TM ADJ2
220
580
1.00
10.00
BOTH
3.30
REPAIRS
35.97
FINAL INSPECTION
150
170
1.80
3.90
PASS
51.37 TOT.
***************************
TEST NO:C0496
AS RECEIVED FROM OWNER ***************************
10/02/73 BAR:24.67 DB: 75 WB:55
REL.HUM:29.0% NOX COR: .877
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
19.68
13.21
11.56
14.10
314.1
312.3
262.0
298.7
393.2
397.8
336.2
379.8
0.57
0.32
0.44
0.41
9.38
9.57
11.35
9.97
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
6912
6311
6050
7.95
10.68
10.90
53
129
156
681
819
789
560
530
585
530
7.60
9.60
*****
9.80
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0566
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
10/08/73 BAR:24.45 DB:72 WB:48
REL.HUM:15.1% NOX COR: .799
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
11.83
6.22
6.03
7.34
176.6
119.8
105.7
127.8
430.4
464.3
399.4
439.2
2.13
1.40
2.28
1.80
11.95
13.25
15.23
13.43
4839
4556
3862
3.70
4.41
2.36
100
841
2156
742
809
691
310
355
250
260
3.50
3.90
2. 20
4. 20
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 195
1973 CHEV CHEV 350 4000LBS
8CYL 2BBL AUTOMATIC 006886 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, EVC, PCV
=====,==========.========.====== MAINTENANCE STATUS ==========.=====*=============
FROM OWNER
FRCM INSP.
I.CO I.RPM
2.90 +0140
0.07 +0200
TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
404 +00 OK OK OK OK NO OK
+04 +00 OK OK OK OK NO OK
IDLE INSPECTION
STATION NO. 7
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
420
420
200
200
2500HC
400
430
200
200
I. CO
4. 10
4.20
1. 10
1.10
2500CO
4.20
4.30
1.10
1.10
FAILURE
BOTH
BOTH
PASS
PASS
COST
2.50
2.50
2.50
7.50 TOT.
***************************
AS RECEIVED :
FROM OWNER
***************************
TEST NO:C0514
10/03/73 BAR
:24.71
DB: 71
WB: 55
REL.HUM:
37.9%
NOX COR:
.901
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
5.76
105.1
593.7
1.74
11.46
COLD STABILIZED
3.54
53.5
619.9
1.59
12.45
HOT TRANSIENT
3.59
55.2
525.7
2.00
14.28
1975 COMPOSITE
4.02
64.8
588.3
1.74
12.67
IDLE KEYMODE
3783
4.02
62
522
215
3.00
LOW CR. KEYMODE
2164
0.20
861
395
100
0. 18
HI. CR. KEYMODE
3034
3.93
462
458
145
3.20
2500 RPM
60
0.23
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0540
10/04/73 BAR:24.88 DB:72 WB:52
REL.HUM:26.1% NOX COR: .846
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.60
3.09
3.36
3.69
70.4
14.3
31.1
30.7
637.6
623.9
519.8
597.9
2.35
1.73
2.02
1.94
11.63
13.57
15.37
13.54
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3867
2313
2241
0.13
0.15
1.72
104
802
1308
1025
742
655
190
110
100
80
0. 10
0. 16
1.50
0.16
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 196
1971 CHEV CAPR 400 4500LBS
8CYL 2BBL AUTOMATIC 036250 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
FROM OWNER
FRCM INSP.
a=======M==tm===s MAINTENANCE STATUS ="=¦
I. CO I.RPM TIM DWL PCV A.CL
0.45 +0290 +04 +00 OK OK
0.45 +0290 +04 +00 OK OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 8
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
120
120
2500HC
70
70
I. CO
0.80
0.80
2500CO
1.70
1.70
FAILURE
PASS
PASS
COST
3.50
3.50 TOT.
***************************
TEST NO:C0513
AS RECEIVED FROM OWNER ***************************
10/03/73 BAR:24.71 DB:75 WB:55
REL.HUM:28.9% NOX COR: .876
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
6.35
83.0
689.6
6.29
10.60
COLD STABILIZED
4.48
35.2
700.6
5.03
11.56
HOT TRANSIENT
4.44
51.0
624.1
6.57
12.40
1975 COMPOSITE
4.86
49.6
677.1
5.72
11.56
IDLE KEYMODE
2890
0.41
416
350
210
0.45
LOW CR. KEYMODE
2873
0.52
2584
359
160
0.50
HI. CR. KEYMODE
3035
1.60
2323
373
160
1.70
2500 RPM
75
1.60
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0513
10/03/73 BAR:24.71 DB:75 WB:55
REL.HUM:28.9% NOX COR: .876
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.35
4.48
4.44
4.86
83.0
35.2
51.0
49.6
689.6
700.6
624.1
677.1
6.29
5.03
6.57
5.72
10.60
11.56
12.40
11.56
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2890
2873
3035
0.41
0.52
1.60
416
2584
2323
350
359
373
210
160
160
75
0.45
0.50
1.70
1.60
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 197
1972 FORD PINT 122 2250LBS
4CYL 2BBL AUTOMATIC 011175 MILES
IDLE INSPECTION ONLY
HAS: EMC, EVC, PCV
=====
:s33==3SBSsss=aa:
======== MAINTENANCE STATUS
I. CO
I.RPM TIM DWL PCV A,
.CL
CHOKE
A.PMP
MISF
FROM
OWNER 6.10
+0310 +00 -04 OK
OK
OK
NA
NO
FROM
INSP. 6.10
+0310 +00 -04 OK
OK
OK
NA
NO
NOXC
NA
NA
IDLE INSPECTION
STATION NO. 10
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
160
2500HC
170
160 170
I.CO 2500CO
1.60 1.00
1.60 1.00
FAILURE COST
PASS 1.50
PASS
1.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0530
10/04/73 BAR:24.94 DB:69 WB:54
REL.HUM:39.5% NOX COR: .894
HC
CO
C02
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.76
4.73
5.93
5.28
104.2
71.5
78.3
80.2
322.6
321.2
304.5
316.8
3.08
2.85
3.33
3.03
17.65
19.86
19.95
19.38
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
4686
4517
5152
6.81
1.74
7.85
86
2068
717
769
769
831
260
250
300
2500 RPM
250
SCO
6. 10
1.50
7.10
5.00
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0530
10/04/73 BAR:24.94 DB:69 WB:54
REL.HUM:39.5% NOX COR: .894
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.76
4.73
5.93
5.28
104.2
71.5
78.3
80.2
322.6
321.2
304.5
316.8
3.08
2.85
3.33
3.03
17.65
19.86
19.95
19.38
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4686
4517
5152
6.81
1.74
7.85
86
2068
717
769
769
831
260
250
300
250
6.10
1.50
7. 10
5.00
AUTOMOTIVE TESTING LABORATORIES.INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 198
1966 CHEV IMPA 283 4000LBS
8CYL 2BBL AUTOMATIC 083297 MILES
TUNE UP EVALUATION
HAS: NO EMC, NO EVC, PCV
FRCM OWNER
FRCM INSP.
I. CO
9.50
7.20
I.RPM
-0020
+0050
MAINTENANCE STATUS ==¦=
TIM DWL
+10 +03
+10 +00
PCV
OK
OK
A.CL
OK
OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA YES NA
STATION NO.
IDLE INSPECTION
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
****
****
8.00
4.80
BOTH
0.00
AFTER I.RPM ADJUST
****
****
8.00
4.80
HC
0.00
AFTER I.MX/TM ADJ1
****
****
5.80
2.90
HC
0.00
AFTER I.MX/TM ADJ2
1600
900
5.90
4.60
HC
0.00
REPAIRS
17.85
FINAL INSPECTION
1600
900
5.90
4.60
HC
150.00
17.85 TOT.
*************************** AS RECEIVED FROM OWNER ************************r.***
TEST NO:C0517
10/03/73 BAR:24.71 DB:69 WB:54
REL.HUM:39.7% NOX COR: .896
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
44.16
45.79
33.74
42.11
181.7
207.8
172.4
192.5
505.8
380.2
394.8
410.5
4.03
1.17
2.57
2.16
9.56
10.45
11.53
10.52
21814
13717
15624
10.98
4.82
7.04
16
824
718
****
****
****
****
****
****
****
9.60
4.80
6.50
7.80
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0541
10/04/73 BAR:24.87 DB:72 WB:52
REL.HUM:26.1% NOX COR: .847
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
14.44
11.40
9.84
11.61
167.8
163.9
158.3
163.1
460.4
412.0
400.7
419.0
3.51
1.77
2.71
2.40
11.57
12.62
13.08
12.51
12268
5997
5061
8.13
6.23
4.39
46
687
1845
2003
1187
1023
1200
540
400
580
7.40
6.20
4.40
6.70
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 199
1967 VOLK SEDA 91 2000LBS
4CYL 1BBL 4 SPEED 068155 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, NO PCV
•======
==>= MAINTENANCE STATUS
ass:
FROM
FROM
OWNER
INSP.
I. CO
6.30
3.56
I. RPM
+0260
+0230
TIM DWL PCV A,
+12 +00 NA
+02 +00 NA
.CL
OK
OK
CHOKE A.PMP MISF. NOXC
OK NA YES NA
BAD NA NO NA
IDLE INSPECTION
STATION NO. 4
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
1550
550
8.20
3.20
BOTH
5.00
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
1175
550
5.40
2.50
HC
1.00
AFTER I.MX/TM ADJ2
550
180
4.20
2.50
PASS
0.00
REPAIRS
FINAL INSPECTION
550
180
4.20
2.50
PASS
6.00 TOT.
*************************** AS RECEIVED FROM OWNER- ***************************
TEST NO:C0518
10/03/73 BAR:24.77 DB:70 WB:55
REL.HUM:40.4% NOX COR: .906
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
6.96
8.90
5.45
7.54
79.0
89.3
68.9
81.5
253.2
246.2
228.3
242.7
4.38
2.56
3.61
3.23
22.30
21.48
25.17
22.58
15226
4881
3979
8.62
3.95
3.84
26
1782
3382
1941
552
479
1050
235
180
750
6. 40
4. 10
4.00
4.70
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0542
10/04/73 BAR:24.88 DB:72 WB:52
REL.HUM:26.1% NOX COR: .846
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.79
4.79
4.25
4.85
75.3
78.8
65.5
74.4
252.5
251.1
216.8
241.9
1.79
0.93
1.30
1.21
22.88
22.83
26.73
23.81
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
5765
3071
2446
4.58
4.19
3.42
56
633
1962
945
781
758
260
180
140
175
3.90
4.00
3.20
3.80
AUTOMOTIVE TESTING LABORATORIES.INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 200
1972 CHEV NOVA 307 3500LBS
8CYL 2BBL AUTOMATIC 015710 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, EVC, PCV
»= MAINTENANCE STATUS =¦==============
I.CO I.RPM TIM DWL
PCV A.CL CHOKE A.PMP MISF.
FROM OWNER 5.75
+0080
+02 +03
BAD
OK
OK
NA
YES
FROM INSP. 1.37
+0050
-01 +00
BAD
OK
OK
NA
YES
IDLE INSPECTION
STATION NO. 2
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
720
240
4.60
1.00
BOTH
5.50
AFTER I.RPM ADJUST
700
240
4.40
l.OO
BOTH
3.30
AFTER I.MX/TM ADJ1
800
140
0.80
0.50
BOTH
3.30
AFTER I.MX/TM ADJ2
300
120
0.70
1.30
PASS
3.30
REPAIRS
FINAL INSPECTION
300
120
0.70
1.30
PASS
NOXC
NA
NA
15.40 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0531
10/04/73 BAR:24.94 DB:70 WB:54
REL.HUM:36.9% NOX COR: .888
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
9.90
7.78
6.94
7.99
160.4
117.7
109.4
124.3
498.3
516.6
447.1
493.5
1.64
1.61
1.76
1.66
11.39
12.26
13.89
12.47
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
6233
4756
5561
6.45
1.47
4.12
82
1133
839
1231
891
1001
570
270
420
160
5.80
1.30
3.60
1.30
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0555
10/05/73 BAR
REL.HUM:
:24.68
33.9%
DB: 70
NOX COR;
WB: 53
; .875
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
8.94
5.35
6.20
6.33
156.3
61.9
95.3
90.9
515.9
580.8
475.6
538.0
1.13
1.64
1.53
1.50
11.28
12.81
13.81
12.71
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4388
3891
5988
1.52
1.18
9.78
159
767
139
816
708
896
340
210
410
105
1.50
1.00
9.00
2.00
AUTOMOTIVE
TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 201
1973 FORD PINT 122 2500LBS
4CYL 1BBL AUTOMATIC 010729 MILES
IDLE INSPECTION ONLY
HAS: EMC, EVC, PCV
=================:='=:=========== MAINTENANCE STATUS ==============================
I.CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 10.40 -0140 -K)6 -02 NA BAD OK NA NO NA
FRCM INSP. 3.20 -0050 +00 -K)0 NA OK OK NA NO NA
IDLE INSPECTION
STATION NO. 1
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
350
270
9.80
*****
BOTH
2.50
270
290
8.80
*****
CO
2.00
90
240
0.20
9.00
CO
3.00
170
250
2.80
8.60
CO
0.00
21.90
100
210
0.20
8.00
CO
40.00
29.40 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0532
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
10/04/73 BAR:24.94 DB:70 WB:54
REL.HUM:36.9% NOX COR: .888
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
11. 10
12.22
6.78
10.48
176.7
185.7
122.0
166.1
299.3
249.5
255.2
261.5
1.14
0.65
1.31
0.94
14.55
15.35
19.02
16.03
12725
4926
4312
11.57
7.10
6.95
13
363
420
1363
933
805
630
320
235
520
*****
6.20
6.20
*****
************************* A.S RECEIVED FROM INSPECTION ************************
TEST NO:C0556
10/05/73 3AR:24.65 DB:72 WB:52
REL.HUM:26.3% NOX COR: .849
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
9.96
5.55
4.12
6.08
176.8
149.3
114.9
145.5
307.2
288.5
277.5
289.3
1.12
0.87
1.21
1.02
14.44
16.47
18.90
16.58
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4135
5253
4081
3.51
9.43
5.83
65
133
735
653
834
690
230
390
250
360
3.20
9. 10
1.50
*****
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 202
1973 DATS 1200 71 2000LBS
4CYL 1BBL 4 SPEED 000519 MILES
IDLE INSPECTION ONLY
HAS: EMC, EVC, NO PCV
============================== MAINTENANCE STATUS ==============================
I. CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 0.13 -0050 -K)5 -09 NA OK OK NA NO BAD
FROM INSP. 0.13 -0050 405 -09 NA OK OK NA NO BAD
IDLE INSPECTION
STATION NO. 5
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
280
280
2500HC
100
100
I. CO
0.20
0.20
2500CO
1.60
1.60
FAILURE
PASS
PASS
COST
5.50
5.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0533
10/04/73 BAR:24.94 DB:71 WB:54
REL.HUM:34.5% NOX COR: .882
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
3.46
2.56
4.15
3.19
58.3
28.7
31.2
35.6
274.2
315.8
247.9
288.2
1.79
1.44
2.00
1.67
23.64
24.13
28.71
25.14
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3955
2580
3404
0.17
0.59
3.25
79
1229
1410
770
533
628
220
100
170
140
0.13
0.50
3.30
3.20
************************* Ag RECEIVED FROM INSPECTION ************************
TEST NO:C0533
10/04/73 BAR:24.94 DB:71 WB:54
REL.HUM:34.5% NOX COR: .882
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
3.46
2.56
4.15
3.19
58.3
28.7
31.2
35.6
274.2
315.8
247.9
288.2
1.79
1.44
2.00
1.67
23.64
24. 13
28.71
25.14
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3955
2580
3404
0.17
0.59
3.25
79
1229
1410
750
533
628
220
100
170
140
0. 13
0.50
3.30
3.20
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 203
1973 CHRY NEWP 400 4500LBS
8CYL 2BBL AUTOMATIC 059407 MILES
IDLE INSPECTION ONLY
HAS: EMC, EVC, PCV
•== MAINTENANCE STATUS
I.CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FRCM OWNER 6.40 -0160 -05 +00 OK OK OK NA NO OK
FROM INSP. 3.10 -0260 +00 +00 OK OK OK NA NO OK
STATION NO. 3
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
500
100
4.50
5.00
BOTH
0.00
300
100
4.70
5.00
CO
0.00
225
100
4.20
5.80
CO
0.00
250
130
4.00
4. 60
CO
12.00
21.45
190
220
1.50
2.80
PASS
33.45 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0529
10/04/73 BAR:24.94 DB:75 WB:55
REL.HUM:28.7% NOX COR: .874
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
17.07
12.05
9.53
12.40
231.4
204.9
154.8
196.6
562.3
617.2
534.0
582.6
1.36
1.03
1.58
1.26
9.09
9.11
11.03
9.57
7517
4214
4596
7.51
1.34
3.42
34
1273
1259
1110
725
734
470
170
155
90
6.50
1.20
2.80
1.70
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0545
10/05/73 BAR:24.84 DB:71 WB:55
REL.HUM:37.8% NOX COR: .899
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
12.87
5.66
6.63
7.44
192.7
91.5
129.0
123.1
628.4
745.4
579.6
674.9
1.79
1.64
1.67
1.68
9.16
9.82
11.09
9.99
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
5011
3383
3953
3.27
0. 66
4.53
52
1002
690
713
603
631
280
170
180
85
3. 20
0.65
4.20
1.65
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 204
1970 FORD GALA 390 4000LBS
8CYL 2BBL AUTOMATIC 020723 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
============================ MAINTENANCE STATUS =============================
I. CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 0.59 -0200 +01 +03 OK OK OK OK NO NA
FROM INSP. 0.59 -0200 +01 +03 OK OK OK OK NO NA
STATION NO. 6
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC
190
2500HC
150
190 150
I. CO 2500CO
0.90 2.90
0.90 2.90
FAILURE COST
PASS 4.50
PASS
4.50 TOT.
***************************
TEST NO:C0543
AS RECEIVED FROM OWNER ***************************
10/05/73 BAR:24.83 DB:71 WB:56
REL.HUM:41.1% NOX COR: .917
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
HC
8.75
4.28
4.64
5.32
CO
153.8
65.0
70.5
85.1
C02
623.6
657.6
569.2
625.9
NOX
4.83
3.86
5.42
4.50
MPG
9.97
11.52
12.82
11.47
LHC
SHC
SCO
IDLE KEYMODE
2394
1.01
339
908
155
0.70
LOW CR. KEYMODE
3482
2.49
2377
751
230
2.30
HI. CR. KEYMODE
3250
2.89
2544
699
170
2.60
2500 RPM
95
3. 10
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0543
10/05/73 BAR:24.83 DB:71 WB:56
REL.HUM:41.1% NOX COR: .917
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
8.75
4.28
4.64
5.32
153.8
65.0
70.5
85.1
623.6
657.6
569.2
625.9
4.83
3.86
5.42
4.50
9.97
11.52
12.82
11.47
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2394
3482
3250
1.01
2.49
2.89
339
2377
2544
908
751
699
155
230
170
95
0.70
2.30
2.60
3.10
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 205
1969 CHEV STAW 350 4500LBS
8CYL 4BBL AUTOMATIC 093878 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
==========================>== MAINTENANCE STATUS ==============================
I. CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 3.90 +0000 -02 +00 OK BAD OK NA NO NA
FROM INSP. 0.65 +0000 -02 +00 OK OK OK NA NO NA
STATION NO. 9
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
700
300
300
300
2500HC
300
180
180
180
I. CO
5.80
1.00
1.00
1.00
2500CO
2.60
1. 20
1.20
1.20
FAILURE
BOTH
PASS
PASS
PASS
COST
0.00
0.00
0.00
10.87
10.87 TOT.
***************************
TEST NO:C0544
AS RECEIVED FROM OWNER ***************************
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
HC
6.79
5.92
4.76
5.78
CO
101.0
85.4
50.1
78.9
C02
591.5
584.9
524.0
569.4
10/05/73 BAR:24.84 DB:71 WB:56
REL.HUM:41.1% NOX COR: .917
NOX
4.67
3.04
4.95
3.91
MPG
11.54
12.07
14.41
12.52
LHC
SHC
SCO
IDLE KEYMODE
4646
4.40
105
853
350
3.80
LOW CR. KEYMODE
3831
1.56
1418
752
260
1.40
HI. CR. KEYMODE
3285
0.39
2807
665
180
0.38
2500 RPM
120
2.20
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0568
10/08/73 BAR:24.43 DB:74 WB:48
REL.HUM:12.0% NOX COR: .789
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.16
4.73
5.57
5.47
122.9
51.3
77.1
73.5
574.3
582.2
534.9
567.4
3.66
2.70
3.93
3.24
11.27
13. 14
13.22
12.72
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3769
4025
3251
0.81
2.12
0.62
192
1340
3167
729
761
679
285
265
185
115
0.70
1.80
0.60
2.40
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 206
1965 CADI FLEE 429 5500LBS
8CYL 4BBL AUTOMATIC 053146 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
.======= MAINTENANCE STATUS ====
FROM OWNER
FROM INSP.
I. CO
6.30
6.30
I.RPM
-0420
-0420
TIM DWL
400 +00
+00 +00
PCV
OK
OK
A.CL
OK
OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
STATION NO. 8
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC
620
2500HC
300
620 300
I.CO 2500CO
5.60 4.40
5.60 4.40
FAILURE
PASS
PASS
COST
3.50
3.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0548
10/05/73 BAR:24.84 DB:71 WB:55
REL.HUM:37.8% NOX COR: .899
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
15.66
14.97
9.79
13.67
211.0
172.2
139.8
171.3
646.8
555.8
511.6
562.6
4.28
2.70
3.62
3.29
8.66
10.19
11.68
10. 18
11533
4733
4078
7.03
4.48
4.92
35
1086
1122
1289
823
724
170
340
260
270
6.50
4.30
4.70
4.70
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0548
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
10/05/73 BAR:24.84 DB:71 WB:55
REL.HUM:37.8% NOX COR: .899
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
15.66
14.97
9.79
13.67
211.0
172.2
139.8
171.3
646.8
555.8
511.6
562.6
4.28
2.70
3.62
3.29
8.66
10.19
11.68
10.18
11533
4733
4078
7.03
4.48
4.92
35
1086
1122
1289
823
724
170
340
260
270
6.50
4.30
4.70
4.70
AUTOMOTIVE TESTING LABORATORIES.INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 207
1972 VOLK SQBK 97 2500LBS
4CYL OBBL 4 SPEED 011511 MILES
IDLE INSPECTION ONLY
HAS: EMC, EVC, NO PCV
==========,================== MAINTENANCE STATUS ==============================
I.CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 2.90 +0160 +05 -01 NA OK NA NA NO NA
FROM INSP. 2.90 +0160 +05 -01 NA OK NA NA NO NA
STATION NO. 4
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC
80
80
2500HC
55
55
I. CO
1.00
2500CO
1. 10
1.00 1.10
FAILURE COST
PASS 5.00
PASS
5.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0557
10/08/73 BAR:24.46 DB:69 WB:49
REL.HUM:23.6% NOX COR: .826
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.50
5.27
3.70
5.09
42.3
40.1
21.6
35.4
346.2
377.2
319.4
354.7
5.20
3.25
4.63
4.04
20.55
19.49
24.40
20.89
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2964
999
1319
3.03
0.20
0.14
99
1083
3501
445
.433
465
115
70
80
2.90
0.08
0.08
2500 RPM
110
2.40
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0557
10/08/73 BAR:24.46 DB:69 WB:49
REL.HUM:23.6% NOX COR: .826
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.50
5.27
3.70
5.09
42.3
40.1
21.6
35.4
346.2
377.2
319.4
354.7
5.20
3.25
4.63
4.04
20.55
19.49
24.40
20.89
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2964
999
1319
3.03
0.20
0.14
99
1083
3501
445
433
465
115
70
80
110
2.90
0.08
0.08
2.40
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 208
1971 DATS 510 97 2000LBS
4CYL 1BBL 4 SPEED 027615 MILES
IDLE INSPECTION ONLY
HAS: EMC, NO EVC, PCV
FRCM OWNER
FRCM. INSP.
I. CO
3.50
2.45
=======»= MAINTENANCE STATUS =========«=======»========
I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
-0200 -04 -07 NA BAD OK NA NO NA
+0000 -05 -03 NA BAD OK NA NO NA
IDLE INSPECTION
STATION NO. 5
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
160
130
130
2500HC
150
110
110
I. CO
6.80
1.80
1.80
2500CO
1.80
2. 10
2.10
FAILURE
BOTH
BOTH
PASS
COST
5.50
5.50
11.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0558
10/08/73 BAR:24.45 DB:69 WB:49
REL.HUM:23.6% NOX COR: .826
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.28
4.65
3.94
4.37
36.2
47.7
36.8
42.2
343.2
338.4
282.3
323.8
4.83
2.90
4.01
3.61
21.53
20.81
25.26
22.04
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
8242
3907
3354
4.78
2.36
1.00
24
2507
3800
822
787
672
270
190
165
230
3.50
1.65
0.80
0.65
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0586
10/09/73 BAR
REL.HUM:
:24.39
30.9%
DB : 70
NOX COR:
WB:52
: .862
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
8.41
3.26
3.36
4.36
64.3
42.0
42.0
46.6
331.6
337.2
285.6
321.7
4. 06
2. 20
3.35
2.91
19.39
21.54
24.58
21.79
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4352
3821
3302
3.31
2.76
1.04
39
2221
4108
393
551
494
130
150
150
290
2.50
1.80
0.80
0.70
AUTOMOTIVE
TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 209
1966 BUIC ELEC 401 4500LBS
8CYL 4BBL AUTOMATIC 056428 MILES
IDLE INSPECTION ONLY
HAS: EMC, NO EVC, PCV
============================== MAINTENANCE STATUS ==============================
I. CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FRCM OWNER 5.20 -0040 -02 +00 OK BAD OK NA NO NA
FROM INSP. 5.50 -K)050 402 +00 OK BAD OK NA NO NA
IDLE INSPECTION
STATION NO. 7
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
840
500
6.10
4.20
BOTH
2.50
850
620
6.20
4.20
BOTH
2.50
400
380
3.40
3.20
PASS
2.50
2.50
400
380
3.40
3.20
PASS
10.00
***************************
TEST NO:C0559
AS RECEIVED FROM OWNER ***************************
10/08/73 BAR:24.45 DB:74 WB:52
REL.HUM:22.7% NOX COR: .840
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
14.95
12.98
9.81
12.51
175.5
149.4
131.0
149.8
527.6
478.2
462.2
484.1
3.81
2.25
3.32
2.88
10.47
11.81
12.74
11.74
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
8196
4977
4650
5.62
3.25
3.88
44
1491
1545
902
803
737
580
365
295
2500 RPM
275
5. 10
3.10
3.10
3.60
************************* A.g RECEIVED FROM INSPECTION ************************
TEST NO:C0585
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
10/09/73 BAR:24.39 DB:71 WB:53
REL.HUM:31.8% NOX COR: .872
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
16.71
13.50
10.30
13.29
178.8
147.8
127.3
148.6
572.2
486.0
428.3
488.0
4.32
2.62
3.35
3. 18
9.83
11.70
13.47
11.67
8582
5244
4809
5.98
3.23
3.46
37
1667
2010
1138
814
724
610
370
310
335
5.10
3.00
3.20
3.80
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 210
1973 VOLK SEDA 97 2000LBS
4CYL 1BBL 4 SPEED 015868 MILES
TUNE UP EVALUATION
HAS: EMC, EVC, NO PCV
==s=»=a=========>===========si MAINTENANCE STATUS ===========m»=====s»=3======3====
I. CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FRCM OWNER 6.70 -0100 +05 +02 NA OK OK NA NO NA
FROM INSP. 2.55 -0100 +00 +04 NA OK OK NA NO NA
IDLE INSPECTION
STATION NO. 5
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
300
180
180
2500HC
210
140
140
I. CO
6.00
3.20
2500CO
3.20
2.20
3.20 2.20
FAILURE
CO
PASS
PASS
COST
5.50
5.50
11.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0571
10/08/73 BAR:24.42 DB:72 WB:49
REL.HUM:17.9% NOX COR: .811
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.82
6.22
5.39
6.33
100.4
95.4
76.8
91.3
296.7
293.5
265.7
286.5
3.12
1.79
3.00
2.40
18.58
19.23
22.07
19.80
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
5549
3772
2861
7.19
3.25
0.75
66
1371
3834
798
743
716
270
230
160
290
7.00
3. 20
0.70
5.10
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0592
10/10/73 BAR:24.68 DB:72 WB:53
REL.HUM:29.3% NOX COR: .863
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.86
5.48
5.31
5.72
91.1
81.0
71.2
80.4
333.7
335.7
296.5
324.4
4.07
2.53
3.31
3.07
17.86
18.54
20.94
19.00
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3604
3652
2787
2.83
2.98
0.62
81
1621
3921
293
378
326
140
165
115
140
2.55
2.50
0.55
2.90
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 211
1970 PLYM FURY 318 4000LBS
8CYL 2BBL AUTOMATIC 063652 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
============================== MAINTENANCE STATUS ==============================
I. CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 2.80 +0060 +10 -10 OK BAD OK NA YES NA
FROM INSP. 3.50 +0000 +03 -09 OK BAD OK NA NO NA
IDLE INSPECTION
STATION NO. 3
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
2000
200
200
150
2500HC
****
****
****
100
I. CO
3.00
2.60
2.50
2.50
2500CO
0.50
1.50
1.50
2.00
FAILURE
HC
HC
HC
PASS
COST
0.00
0.00
0.00
51.08
51.08 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0573
10/09/73 BAR:24.39 DB:74 WB:53
REL.HUM:25.5% NOX COR: .855
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
33.83
26.66
29.43
28.93
152.1
110.6
117.0
121.0
516.2
490.3
444.2
483.0
4.03
3.33
3.55
3.54
10.33
11.90
12.34
11.65
13683
5991
13655
3.58
3.23
7.52
185
1458
460
****
1146
****
****
600
1900
****
2.80
2.90
6. 10
1.50
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0601
10/10/73 BAR: 24.66 DB:71.WB:52
REL.HUM:28.4% NOX COR: .854
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.91
5.20
5.58
5.87
143.7
100.9
97.7
109.0
572.4
544.8
430.4
518.8
2.94
2.64
2. 17
2.57
10.82
12.37
14.80
12.57
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3556
3592
3417
3.92
2.89
3.68
68
1315
1219
365
461
430
140
170
130
120
3. 10
2.20
3.00
2.20
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 212
1967 FORD MUST 289 3000LBS
8CYL 2BBL 3 SPEED 051835 MILES
TUNE UP EVALUATION
HAS: NO EMC, NO EVC, PCV
============
=======
========
== MAINTENANCE STATUS =====
I. CO
I.RPM
TIM DWL
PCV
A.CL
FROM OWNER
9.85
-0250
-02 +02
OK
OK
FRCM INSP.
5.60
-0100
-02 +00
OK
OK
T HI F TMQPRPTTfiM
j.uLtCt lnorijuiiuii
STATION NO
. 10
I.HC
2500HC
I. CO
2500C0
INITIAL INSPECTION
800
250
6.50
6.00
AFTER I.RPM
ADJUST
400
150
7.00
0.40
AFTER I.MX/TM ADJ1
250
150
3.90
1.80
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
250
150
3.90
1.80
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
FAILURE
CO
CO
PASS
PASS
COST
1.50
1.50
1.50
4.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0572
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
10/08/73 BAR:24.42 DB:72 WB:48
REL.HUM:15.2% NOX COR: .799
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
16.37
16.63
12.00
15.29
173.1
181.1
130.7
165.4
302.0
292.7
296.0
295.6
0.85
0.52
1.25
0.79
14.23
14.14
16.51
14.75
16921
4953
4627
10.35
4.37
4.05
17
917
1250
1368
901
873
740
335
320
450
*****
4.00
3.80
5.00
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0593
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
10/10/73 BAR:24.68 DB:73 WB:52
REL.HUM:24.3% NOX COR: .843
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
10.87
11.32
7.52
10.17
141.4
142. 1
107.8
132.4
339.2
344.9
319.8
336.8
1.35
0.85
1.65
1.18
14.94
14.74
17.36
15.44
5771
4890
4721
5.98
3.95
4.23
54
639
1125
484
636
613
285
310
270
295
5.50
3.50
3.60
4.70
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 213
1966 CHEV STAW 283 4000LBS
8CYL 2BBL 3 SPEED 061637 MILES
IDLE INSPECTION ONLY
HAS: EMC, NO EVC, PCV
============================== MAINTENANCE STATUS ==============================
I. CO I.RPM TIM DWL PCV A.CL
FRCM OWNER 5.70 +0000 +02 +00 OK OK
FROM INSP. 5.70 +0000 +02 +00 OK OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
STATION NO. 2
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
600
IDLE INSPECTION
2500HC
260
600 260
I.CO 2500CO
5.75 4.25
5.75 4.25
FAILURE COST
PASS 5.50
PASS
5.50 TOT.
*************************** RECEIVED FROM OWNER ***************************
TEST NO:C0574
10/09/73 BAR:24.39 DB:71 WB:53
REL.HUM:31.8% NOX COR: .872
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
13.45
15.88
11.48
14.15
145.9
174.6
138.8
158.7
463.6
550.2
450.7
504.5
2.32
2.15
2.51
2.28
12. 11
10.18
12.63
11. 15
10189
5621
5548
6.06
4.58
7.32
37
941
432
1391
1005
989
570
350
335
375
5.30
4.00
6.60
5.90
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST N0:C0574
10/09/73 BAR:24.39 DB:71 WB:53
REL.HUM:31.8% NOX COR: .872
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
13.45
15.88
11.48
14.15
145.9
174.6
138.8
158.7
463.6
550.2
450.7
504.5
2.32
2.15
2.51
2.28
12. 11
10.18
12.63
11.15
10189
5621
5548
6.06
4.58
7.32
37
941
432
1391
1005
989
570
350
335
375
5.30
4.00
6.60
5.90
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 214
1966 PONT CATA 389 4000LBS
8CYL 2BBL AUTOMATIC 046086 MILES
TUNE UP EVALUATION
HAS: NO EMC, NO EVC, PCV
==5S=n==aaa3*aa3=3=33===aBaa== MAINTENANCE STATUS ====3===a====a3===3a3==a=oa3
I. CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FRCM CWNER 3.30 -0060 -03 +00 BAD OK OK NA NO NA
FRCM INSP. 3.30 -0060 -03 +00 BAD OK OK NA NO NA
STATION NO. 1
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
580
IDLE INSPECTION
2500HC
150
580 150
I. CO
2.60
2500CO
2.40
2.60 2.40
FAILURE COST
PASS 2.50
PASS
2.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0575
10/09/73 BAR:24.40 DB:71 WB:53
REL.HUM:31.8% NOX COR: .872
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
10.70
7.20
6.21
7.66
167.1
103.3
86.7
112.0
490.3
477.5
444.4
471.0
2.83
1.69
3.43
2.41
11.32
13.44
14.84
13.27
5654
4099
3940
3.64
1.42
2.44
58
1739
2018
895
776
735
400
245
210
200
3.20
1.30
2.10
2.80
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0575
10/09/73 BAR:24.40 DB:71 WB:53
REL.HUM:31.8% NOX COR: .872
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
10.70
7.20
6.21
7.66
167.1
103.3
86.7
112.0
490.3
477.5
444. 4
471.0
2.83
1.69
3.43
2.41
11.32
13.44
14.84
13.27
5654
4099
3940
3.64
1.42
2.44
58
1739
2018
895
776
735
400
245
210
200
3.20
1.30
2.10
2.80
AUTOMOTIVE TESTING LABORATORIES, INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 217
1972 CADI COUP 472 5000LBS
8CYL 4BBL AUTOMATIC 017251 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, EVC, PCV
FROM OWNER
FROM INSP.
laaaaaaasaaasaasa MAINTENANCE STATUS
I.CO I.RPM TIM DWL PCV A.CL
2.95 +0020 +02 +02 OK BAD
2.95 +0020 +02 +02 OK BAD
CHOKE A.PMP ' MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 6
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
180
180
2500HC
50
50
I.CO 2500CO
3.20 0.50
3.20 0.50
FAILURE COST
PASS 4.50
PASS
4.50 TOT.
***************************
TEST NO:C0588
AS RECEIVED FROM OWNER ***************************
10/10/73 BAR:24.68 DB:72 WB:53
REL.HUM:29.3% NOX COR: .863
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.54
2.24
3.55
3.08
141.7
88.7
103.6
103.9
882.9
854.5
707.6
819.7
2.96
1.82
2.79
2.33
7.95
8.90
10. 10
8.97
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2088
1747
1485
3.71
2.86
1.88
64
404
1402
260
284
291
235
180
145
2500 RPM
95
2.95
2.20
1.60
0.60
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0588
10/10/73 BAR:24.68 DB:72 WB:53
REL.HUM:29.3% NOX COR: .863
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.54
2.24
3.55
3.08
141.7
88.7
103.6
103.9
882.9
854.5
707.6
819.7
2.96
1.82
2.79
2.33
7.95
8.90
10. 10
8.97
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2088
1747
1485
3.71
2.86
1.88
64
404
1402
260
284
291
235
180
145
95
2.95
2.20
1.60
0.60
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 218
1973 CHEV NOVA 307 3500LBS
8CYL 2BBL AUTOMATIC 016372 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, EVC, PCV
FROM OWNER
FROM INSP.
MAINTENANCE STATUS =¦==
I. CO I.RPM TIM DWL PCV A.CL
4.10 -0040 +01 -04 OK OK
4.10 -0040 +01 -04 OK OK
CHOKE A.PMP MISF. NOXC
OK NA NO OK
OK NA NO OK
IDLE INSPECTION
STATION NO. 9
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
HO
110
2500HC
60
60
I. CO 2500CO
1.10 0.50
1.10 0.50
FAILURE COST
PASS 4.00
PASS
4.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0589
10/10/73 BAR:24.68 DB:76 WB:54
REL.HUM:24.3% NOX COR: .855
HC
CO
CO 2
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
9.51
4.95
5.65
6.10
132.8
87.6
97.4
99.8
491.6
550.9
462.5
514.0
1.51
1.41
1.74
1.52
12.19
12.65
14.06
12.91
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
3522
4111
3453
5.00
3.23
3.98
47
755
700
388
532
446
175
210
160
SCO
2500 RPM
95
4. 10
2.50
3.30
0.50
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0589
10/10/73 BAR:24.68 DB:76 WB:54
REL.HUM:24.3% NOX COR: .855
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
9.51
4.95
5.65
6.10
132.8
87.6
97.4
99.8
491.6
550.9
462.5
514.0
1.51
1.41
1.74
1.52
12. 19
12.65
14.06
12.91
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3522
4111
3453
5.00
3.23
3.98
47
755
700
388
532
446
175
210
160
95
4. 10
2.50
3.30
0.50
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 219
1968 CHRY STAW 383 4500LBS
8CYL 4BBL AUTOMATIC 071302 MILES
IDLE INSPECTION ONLY
HAS: EMC, NO EVC, PCV
FROM OWNER
FROM INSP.
I. CO I. RPM
5.40 +0050
0.80 -0050
== MAINTENANCE STATUS =================«™=========:==»
TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
+00 +00 OK BAD OK NA NO NA
+00 +00 OK BAD OK NA NO NA
IDLE INSPECTION
STATION NO. 3
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
110
100
120
120
2500HC
100
100
200
200
I. CO
2.00
4.50
0.50
0.50
2500CO
5.30
5.00
3.50
3.50
FAILURE
CO
CO
PASS
PASS
COST
0.00
0.00
0.00
12.00
12.00 TOT.
***************************
TEST NO:C0604
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
AS RECEIVED FROM OWNER ***************************
10/11/73 BAR:24.51 DB:71 WB:53
REL.HUM:31.7% NOX COR: .871
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
12.56
8.67
8.82
9.52
241.3
171.6
157.8
182.4
560.5
556.0
517.3
546.2
2.87
2.93
3.71
3. 13
9.09
10.44
11.23
10.32
4553
4658
4226
6.61
5.30
4.75
65
1038
1383
443
590
528
190
255
190
175
5.30
5.00
4. 10
5.20
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0629
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
10/12/73 BAR:24.53 DB:71 WB:49
REL.HUM:19.6% NOX COR: .815
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
10.36
6.58
6.51
7.35
214.9
103.3
108.9
128.2
608.7
605.5
531.9
585.7
3.08
3.85
4.68
3.92
9. 10
11.29
12.31
10.99
6245
4714
3975
0.88
4.52
3.99
98
1424
1767
866
546
451
200
110
80
200
0.90
4.30
3.90
4.60
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 220
1968 BUIC LESA 350 4500LBS
8CYL 4BBL AUTOMATIC 074568 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
aaaaaaaaaaaa
aaaassas
aaass&aaa
»= MAINTENANCE STATUS
aaaaa:
I. CO
I. RPM
TIM DWL
PCV A
.CL i
FROM OWNER
7.50
+0210
+00 +00
OK
OK
FROM INSP.
0.19
+0000
+00 -06
OK
OK
IDLE INSPECTION -
STATION NO
. 2
I.HC
2500HC
I. CO
2500CO
INITIAL INSPECTION
280
370
7.60
5.20
AFTER I.RPM
ADJUST
290
360
6.40
5.00
AFTER I.MX/TM ADJ1
150
250
0.50
3.20
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
150
250
0.50
3.20
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
FAILURE
BOTH
BOTH
PASS
PASS
COST
5.50
3.30
3.30
12.10 TOT.
*****************AAAAAA*AAA
TEST NO:C0605
AS RECEIVED FROM OWNER ***************************
10/11/73 BAR:24.51 DB:71 WB:53
REL.HUM:31.7% NOX COR: .871
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
14.94
7.87
7.33
9.20
237.5
201.1
170.3
200.2
456.7
476.0
400.8
451.1
1.69
0.84
1.79
1.28
10. 15
10.90
12.88
11.21
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4709
4392
5218
7.92
4.74
10.13
69
700
223
525
644
743
270
290
320
265
7.40
4.40
8.60
5.80
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0630
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
10/12/73 BAR:24.53 DB:71 WB:49
REL.HUM:19.6% NOX COR: .815
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
12.54
5.37
5.35
6.86
211.2
110.3
129.8
136.8
461.7
516.7
403.2
473.7
2.02
1.28
1.86
1.60
10.69
12.60
14.27
12.54
2171
4198
3905
0.23
3.72
3.08
140
1013
1867
285
563
522
140
330
265
275
0.20
3.60
3. 10
4.10
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 221
1964 PONT GRAN 389 4000LBS
8CYL 4BBL AUTOMATIC 074401 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
FROM OWNER
FROM INSP.
I.CO I.RPM
5.80 +0140
I.10 +0230
¦» MAINTENANCE STATUS »=«
TIM DWL PCV A.CL
-02 -06 OK BAD
-01 -06 OK BAD
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 7
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
460
480
380
380
2500HC
520
520
360
360
I. CO
4.30
5.30
3.40
3.40
2500CO
5.30
5.40
4.00
4.00
FAILURE
BOTH
BOTH
PASS
PASS
COST
2.50
2.50
2.50
10.00
17.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0606
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
10/1/7 BAR:24.51 DB:70 WB:52
REL.HUM:30.8% NOX COR: .861
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
20.54
18.67
15.52
18.19
298.9
297.5
289.1
295.5
356.0
335.9
281.3
324.9
0.56
0.30
0.31
0.36
10.00
10.33
11.35
10.52
11558
8941
7807
9.61
13.19
12.52
21
94
158
1161
993
885
420
800
610
750
5.80
*****
*****
9.80
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0631
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
10/12/73 BAR:24.56 DB:70 WB:49
REL.HUM:21.5% NOX COR: .820
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
15.27
10.71
10.95
11.73
293. 1
237.3
286.0
262.5
409.6
454.0
364.7
419.9
0.75
0.89
0.71
0.81
9.69
10.35
10.49
10.25
4484
7319
6819
1.65
12.13
12.26
515
117
137
575
883
815
350
610
550
620
1.10
9.80
*****
10.00
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 222
196A AMMO AMER 196 3000LBS
6CYL 1BBL 3 SPEED 068526 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
FROM OWNER
FROM INSP.
isaasaaaMaaasnM MAINTENANCE STATUS "=
I.CO I.RPM TIM DWL PCV A.CL
0.28 +0150 +00 -07 NA BAD
0.28 +0150 +00 -07 NA BAD
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. .10
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
120
120
2500HC
140
1A0
I. CO
0.20
0.20
2500CO
1.70
1.70
FAILURE
PASS
PASS
COST
1.50
1.50 TOT.
***************************
TEST NO:C0607
AS RECEIVED FROM OWNER ***************************
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
HC
8.55
5.42
6.31
6.32
10/11/73 BAR:24.51 DB:70 WB:53
REL.HUM:34.0% NOX COR: .876
CO
95.0
62.5
86.6
76.0
C02
387.6
416.9
339.0
389.1
NOX
3.29
3.27
2.37
3.02
MPG
15.79
16.74
17.99
16.85
LHC
SHC
SCO
IDLE KEYMODE
3523
0.33
186
476
275
0.30
LOW CR. KEYMODE
4150
3.38
1207
605
350
3.40
HI. CR. KEYMODE
5510
9.24
285
764
450
9.20
2500 RPM
380
4.60
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0607
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
10/11/73 BAR:24.51 DB:70 WB:53
REL.HUM:34.0% NOX COR: .876
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
8.55
5.42
6.31
6.32
95.0
62.5
86.6
76.0
387.6
416.9
339.0
389.1
3.29
3.27
2.37
3.02
15.79
16.74
17.99
16.85
3523
4150
5510
0.33
3.38
9.24
186
1207
285
476
605
764
275
350
450
380
0.30
3.40
9.20
4.60
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 223
1964 BUIC WILD 401 4500LBS
8CYL 4BBL AUTOMATIC 051818 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
MAINTENANCE STATUS ==
FROM OWNER
FROM INSP.
I.CO I.RPM
1.90 -0080
3.00 +0020
TIM
+00
+00
DWL
+01
+00
PCV A.CL
OK OK
OK OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 1
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
900
600
600
2500HC
260
200
200
I.CO 2500CO
3.40 3.80
4.20 2.60
4.20
2.60
FAILURE
HC
PASS
PASS
COST
2.50
2.00
4.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0608
10/11/73 BAR:24.51 DB:75 WB:55
REL.HUM:29.1% NOX COR: .879
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
10.68
12.12
8.24
10.74
93.4
124.8
79.9
105.7
459.0
425.2
422.9
431.6
5.72
2.96
4.74
4.03
13.93
13.50
15.50
14. 10
11614
4849
4106
5.69
2.44
1.42
36
1933
3009
1550
637
519
370
410
325
370
1.85
2.25
1.50
3. 10
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0632
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
10/12/73 BAR:24.52 DB:71 WB:50
REL.HUM:22.6% NOX COR: .828
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
10.87
11.22
8.01
10.25
92.6
113.6
78.2
99.4
487.6
468.1
462. 1
470.5
5.40
3.38
5.12
4.29
13.34
13.05
14.59
13.51
9665
5051
4216
6.38
2.88
1.71
41
1670
2756
1140
699
571
390
400
310
300
2.80
2.40
1.40
2.30
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 224
1968 CHEV MALI 250 3500LBS
6CYL IBBL AUTOMATIC 043307 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
FROM OWNER
FROM INSP.
»===»==»="«=¦=¦»== MAINTENANCE STATUS =m=====*m«
I.CO I.RPM TIM DWL PCV A.CL CHOKE
5.90 -0200 -02 -09 OK BAD OK
5.60 -0100 -02 -02 OK BAD OK
A.PMP MISF. NOXC
NA NO NA
NA NO NA
-- IDLE INSPECTION
STATION NO. 6
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJl
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
210
210
210
2500HC
150
140
140
I. CO
4.80
3.80
3.80
2500CO
2.00
1.00
1.00
FAILURE
CO
PASS
PASS
COST
4.50
1.50
6.00 TOT.
***************************
TEST NO:C0617
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
AS RECEIVED FROM OWNER ***************************
10/12/73 BAR:24.48 DB:75 WB:55
REL.HUM:29.1% NOX COR: .879
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
20.39
5.18
5.50
8.45
212.6
114.7
89.3
128.1
459.2
464.8
407.8
447.8
2.46
1.63
2.86
2.15
10.38
13.46
15.75
13. 18
4438
3959
4281
6.41
4.03
4.90
76
652
802
474
413
471
290
210
200
260
5.00
3.00
4.30
2.40
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0655
10/16/73 BAR:24.87 DB:70 WB:54
REL.HUM:37.0% NOX COR: .888
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
20.42
4.29
4.74
7.79
203.1
86.9
73.5
107.5
445.2
450.1
414.0
439.0
2.26
1.51
3.00
2.08
10.74
14.84
16.36
14.08
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4393
3276
4069
6.25
1.90
5.07
65
1063
770
475
351
439
540
360
380
560
5.80
7.80
5.00
3.80
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 225
1968 CHEV STAW 396 4500LBS HIGH ALTITUDE RETROFIT
8CYL 4BBL AUTOMATIC 048577 MILES HAS: EMC, NO EVC, PCV
asaaaaaxSBasaaassiiasasiasaaaas MAINTENANCE STATUS saaassaaaaaaaaassasfisaaasaasas
I.CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 3.30 -0010 +04 +00 OK OK OK NA NO NA
FROM INSP. 1.30 -0050 +11 +00 OK OK OK NA NO NA
IDLE INSPECTION
STATION NO. 8
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
500
260
4.30
5.80
BOTH
0.00
AFTER I.RPM ADJUST
260
170
4.60
4.40
BOTH
0.00
AFTER I.MX/TM ADJl
270
180
1.00
4.60
BOTH
0.00
AFTER I.MX/TM ADJ2
130
150
1.00
4.20
PASS
0.00
REPAIRS
60.15
FINAL INSPECTION
130
150
1.00
4.20
PASS
60.15 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0665 10/17/73 BAR:24.91 DB:69 WB:50
REL.HUM:26.3% NOX COR: .835
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
8.95
5.53
4.92
6.08
212.1
143.9
139.3
156.9
532.6
550. 1
441.5
516.3
1.42
0.88
1.20
1.08
9.96
11.22
13. 18
11.39
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3519
4280
4000
3.61
7.07
6.37
72
229
466
344
546
508
345
610
480
480
3.60
7.20
6.40
8.50
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0689
10/18/73 BAR
REL.HUM:
:24.83
28.3%
DB: 71
NOX COR:
WB: 52
: .852
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
9.11
6.31
5.82
6.76
218.5
161.6
163.5
174.0
523.3
561.3
437.5
519.0
1.36
0.90
0.96
1.01
9.95
10.66
12.49
10.95
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3657
4407
4020
2.03
6.52
6.35
138
348
805
472
601
567
230
325
285
250
1.25
5. 10
5.40
6. 10
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 226
1973 DODG DART 318 3000LBS
8CYL 2BBL AUTOMATIC 003813 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, EVC, PCV
sssaaaaaaaaaa
aaanna
massssaasi
=» MAINTENANCE STATUS
93!
I. CO
I. RPM
TIM DWL PCV A
.CL
FROM OWNER
1.77
-0030
+00 +00 OK
OK
FROM INSP.
5.10
+0000
+00 +00 OK
OK
CHOKE A.PMP MISF. NOXC
OK OK NO OK
OK OK NO OK
STATION NO.
IDLE INSPECTION —
I. HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
440
460
4.10
4.40
BOTH
2.50
AFTER I.RPM ADJUST
430
460
4.20
4.40
BOTH
2.50
AFTER I.MX/TM ADJ1
200
200
2. 10
2. 10
PASS
2.50
AFTER I.MX/TM ADJ2
REPAIRS
2.50
FINAL INSPECTION
200
200
2.10
2. 10
PASS
10.00
***************************
TEST NO:C0633
AS RECEIVED FROM OWNER ***************************
10/15/73 BAR:24.88 DB:70 WB:49
REL.HUM:21.2% NOX COR: .817
HC
4.56
3.43
3.94
3.81
CO
51.0
43.6
51.4
47.3
C02
525.2
520.6
464.7
506.0
NOX
4.84
2.35
4.32
3.42
MPG
14.37
14.84
15.96
15.03
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOTV CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* as RECEIVED FROM INSPECTION ************************
2910
1.88
136
341
370
2.00
3465
2.09
2393
488
460
2.20
3467
2.34
2696
472
430
2.50
250
1.80
TEST NO:C0657
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
10/16/73 BAR:24.86 DB:75 WB:56
REL.HUM:31.7% NOX COR: .891
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
5.19
3.90
3.63
4.10
84. 1
78.9
62.4
75.4
488.5
490.2
448.9
478.4
3.62
1.76
4.19
2.82
13.98
14.22
15.95
14.61
4146
3800
3522
5.92
3.32
3.35
80
1598
1354
515
587
532
500
480
400
280
5.00
3.00
3.30
2.30
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 227
1973 AMMO STAW 304 3000LBS
8CYL 2BBL AUTOMATIC 003437 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, EVC, PCV
FROM OWNER
FROM INSP.
MAINTENANCE STATUS =¦==
I.CO I.RPM TIM DWL PCV A.CL
0.63 -0020 +00 +00 OK OK
0.63 -0020 +00 +00 OK OK
CHOKE A.PMP MISF. NOXC
OK NA YES OK
OK NA YES OK
— IDLE INSPECTION
STATION NO. 9
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
80
80
2500HC
50
50
I. CO
0.20
0.20
2500C0
0.30
0.30
FAILURE
PASS
PASS
COST
0.00
4.00
4.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0634
10/15/73 BAR:24.88 DB:69 WB:50
REL.HUM:26.3% NOX COR: .835
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.36
3.29
3.52
4.00
124.1
43.3
36.3
58.3
582.2
575.6
473.5
548.6
2.32
1.65
2.24
1.95
11.17
13.62
16.44
13.64
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2377
2887
2618
0.81
0.49
0.59
190
867
1719
903
384
395
265
345
265
75
0.65
0.40
0.51
0. 26
* * * ***** AAA * A AAAAAAAA AAA A
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0634
10/15/73 BAR:24.88
REL.HUM:26.3%
DB: 69
NOX COR:
WB: 50
: .835
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.36
3.29
3.52
4.00
124. 1
43.3
36.3
58.3
582.2
575.6
473.5
548.6
2.32
1.65
2.24
1.95
11. 17
13.62
16.44
13.64
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2377
2887
2618
0.81
0.49
0.59
190
867
1719
903
384
395
265
345
265
0.65
0.40
0.51
2500 RPM
75
0.26
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 228
1971 OPEL 1900 116 2250LBS IDt,E INSPECTION ONLY
4CYL 1BBL AUTOMATIC 011626 MILES HAS: EMC, NO EVC, NO PCV
32aa3a3S33=33aa3i3ao3=3zaaaaaa3 MAINTENANCE STATUS sBaaaaaaaasaaaasaaaaaaaasssssa
I.CO I.RPM
FROM 017NER 4.60 +0500
FROM INSP. 4.60 +0500
STATION NO. 5
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION 100
***************************
TEST NO:C0635
HC
COLD TRANSIENT 3.51
COLD STABILIZED 2.74
HOT TRANSIENT 2.53
1975 COMPOSITE 2.84
IDLE KEYMODE 3611
LOW CR. KEYMODE 3546.
HI. CR. KEYMODE 3396
2500 RPM
*************************
TEST NO:C0635
HC
COLD TRANSIENT 3.5
COLD STABILIZED 2.7
HOT TRANSIENT 2.5
1975 COMPOSITE 2.8
IDLE KEYMODE 361
LOW CR. KEYMODE 354
HI. CR. KEYMODE 339
2500 RPM
TIM DWL PCV A.CL
-02 -08 NA OK
-02 -08 NA OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
I.HC 2500HC I.CO 2500C0 FAILURE COST
100 160 2.70 1.05 PASS 5.50
160 2.70 1.05 PASS
5.50 TOT.
AS RECEIVED FROM OWNER ***************************
10/15/73 BAR:24.89 DB:69 WB:50
REL.HUM:26.3% NOX COR: .835
CO C02 NOX MPG LHC SHC SCO
43.5 392.5 4.75 18.87
39.8 326.4 2.57 22.40
28.5 284.1 3.98 26.44
37.4 328.5 3.42 22.47
4.86 113 426 470 5.00
1.21 2335 510 480 1.40
0.29 5039 467 360 1.40
280 1.90
AS RECEIVED FROM INSPECTION ************************
10/15/73 BAR:24.89 DB:69 WB:50
REL.HUM:26.3% NOX COR: .835
CO C02 NOX MPG LHC SHC SCO
1 43.5 392.5 4.75 18.87
4 39.8 326.4 2.57 22.40
3 28.5 284.1 3.98 26.44
4 37.4 328.5 3.42 22.47
1 4.86 113 426 470 5.00
6 1.21 2335 510 480 1.40
6 0.29 5039 467 360 1.40
280 1.90
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 229
1972 VOLK SEDA 97 2000LBS
4CYL 1BBL 4 SPEED 018774 MILES
IDLE INSPECTION ONLY
HAS: EMC, EVC, NO PCV
FROM OWNER
FROM INSP.
.»»»»=,„»=== MAINTENANCE STATUS =¦==
I. CO I.RPM TIM DWL PCV A.CL
7.99 +0030 +02 +00 NA OK
3.60 -0200 +00 +00 NA OK
333=33S3aa:
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 4
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
250
700
180
180
2500HC
190
300
110
110
I. CO
7.90
9.00
1.60
1.60
2500CO
4.20
6.00
3.20
3.20
FAILURE
BOTH
BOTH
PASS
PASS
COST
5.00
1.00
3.00
9.00 TOT.
***************************
TEST NO:C0637
AS RECEIVED FROM OWNER ***************************
10/15/73 BAR:24.89 DB:69 WB:50
REL.HUM:26.3% NOX COR: .835
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.75
5.85
4.95
5.58
82.2
110.7
78.4
95.7
328.8
301.0
272.8
299.0
3.49
1.65
2.63
2.31
18.71
18.05
21.64
19.07
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
6424
3254
2320
9.05
3.15
1.18
60
1331
3670
590
417
434
520
320
220
450
8.80
3.30
1. 20
6.50
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0658
10/16/73 BAR:24.86
REL.HUM:33.9%
DB: 74
NOX COR:
WB: 56
: .897
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.80
5.89
5.11
5.86
81.5
83. 1
78.3
81.4
370.7
369.3
303.9
351.4
2. 10
1.39
1.48
1.56
17. 12
17.17
20. 10
17.89
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
3530
2405
2514
3.96
2.73
2.93
96
750
1301
374
302
340
390
200
210
3.90
2.80
3. 10
2500 RPM
180
4.00
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 230
1966 PLYM BELE 225 3500LBS
6CYL 1BBL 3 SPEED 099^61 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
FROM OWNER
FROM INSP.
MAINTENANCE STATUS ===
I.CO I.RPM TIM DWL PCV A.CL
A.70 +0250 +00 -10 OK BAD
1.45 -0010 +00 +00 OK OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 3
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
150
400
450
450
2500HC
300
300
375
375
I. CO
7.00
2.00
2.50
2.50
25O0CO
7.00
7.00
5.50
5.50
FAILURE
CO
CO
PASS
PASS
COST
0.00
0.00
0.00
12.00
12.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0636
10/15/73 BAR:24.88 DB:69 WB:49
REL.HUM:23.2% NOX COR: .823
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
12.46
7.92
5.68
8.25
135.6
153.8
102.6
135.8
359.1
316.7
290.4
318.3
2.56
0.82
1.68
1.42
14.56
15.26
18.96
15.97
5800
4850
3723
5.16
7.24
4.76
81
542
1438
510
512
472
660
480
420
620
4.90
7.60
4. 70
9.80
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* A.S RECEIVED FROM INSPECTION ************************
TEST NO:C0654
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
10/16/73 BAR:24.92 DB:69 WB:54
REL.HUM:39.5% NOX COR: .894
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
12.63
7.36
6.71
8.28
135.4
124.9
107.4
122.2
356.9
316.5
293.8
318.7
2.67
1.29
1.89
1.74
14.61
16.61
18.41
16.59
4515
4158
3596
1.53
6.31
4.55
54
533
1258
449
503
436
580
460
420
800
1.40
6.70
4.90
10.00
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 231
1973 PLYM DUST 318 3500LBS
8CYL 2BBL AUTOMATIC 007751 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, EVC, PCV
==*===»====»==»===="=> =»=»=»==»======»=«=> MAINTENANCE STATUS ===
I. CO I.RPM TIM DWL PCV A.CL
FROM OWNER 5.70 -0140 +02 +00 OK OK
FROM INSP. 2.89 -0140 +05 +00 OK OK
CHOKE A.PMP MISF. NOXC
OK NA NO OK
OK NA NO OK
IDLE INSPECTION
STATION NO. 3
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ 1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
400
400
200
200
2500HC
150
150
150
150
I. CO
5.10
5.00
2.00
2.00
2500CO
2.50
2.50
2.00
2.00
FAILURE
BOTH
BOTH
PASS
PASS
COST
0.00
0.00
0.00
12.00
12.00 TOT.
***************************
AS 1
RECEIVED
FROM OWNER
* * * * * * it * * * * * jfe * A * * A * afe A "k * * * * ie
TEST NO:C0660
10/17/73 BAR
:24.86
DB :69
WB: 50
REL.HUM:
26.4%
NOX COR
: .836
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
4.62
75.3
470.6
2.86
14.75
COLD STABILIZED
4.13
78.1
434. 1
1.67
15.62
HOT TRANSIENT
3.65
51.0
378.4
3.05
18.94
1975 COMPOSITE
4.10
70.0
426.3
2.30
16.22
IDLE KEYMODE
4873
6.31
61
502
690
6.30
LOW CR. KEYMODE
3481
1.64
2489
464
560
1.80
HI. CR. KEYMODE
3458
3. 13
1490
452
510
3.40
2500 RPM
290
2.40
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO-.C0685
10/18/73 BAR:24.83 DB:83 WB:56
REL.HUM:17.9% NOX COR: .845
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.94
3.88
3.94
4.12
81.9
63.6
71.5
69.6
485.3
501.8
435.0
479.9
3.06
2.03
2.71
2.43
14. 14
14.50
15.91
14. 79
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3451
3638
3751
3.22
2.34
4.35
91
2242
996
442
562
573
260
290
270
150
2.85
2.25
3.70
3.00
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 232
1973 FORD MAVE 200 2500LBS
6CYL 1BBL 3 SPEED 003468 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, EVC, PCV
MAINTENANCE STATUS
isaaas
I.CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 2.65 +0015 400 +00 OK OK OK NA NO OK
FROM INSP. 2.65 +0015 +00 +00 OK OK OK NA NO OK
STATION NO. 10
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC
100
2500HC
100
100 100
I. CO
1.80
2500C0
1.90
1.80 1.00
PASS
FAILURE COST
PASS 1.50
1.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0647
10/16/73 BAR:24.92 DB:71 WB:50
REL.HUM:22.1% NOX COR: .825
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.36
3.67
3.68
4.45
79.7
74.7
54.9
70.3
314.6
330.5
289.0
315.7
1. 11
0.50
1.09
0. 79
19.23
19.38
23.02
20.24
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
3438
4074
4019
3.05
2.05
2.99
58
1206
884
381
584
580
360
590
555
2500 RPM
360
3.00
2. 20
2.90
2.20
************************* AS RECEIVED FROM INSPECTION ************************
TEST N0-.C0647
10/16/73 BAR:24.92 DB :71 WB:50
REL.HUM:22.1% NOX COR: .825
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.36
3.67
3.68
4.45
79.7
74. 7
54.9
70.3
314.6
330.5
289.0
315.7
1.11
0.50
1.09
0.79
19.23
19.38
23.02
20. 24
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3438
4074
4019
3.05
2.05
2.99
58
1206
884
381
584
580
360
590
555
360
3.00
2. 20
2.90
2.20
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 233
1972 BUIC LESA 350 4500LBS
8CYL ABBL AUTOMATIC 020861 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, EVC, PCV
FROM OWNER
FROM INSP.
I. CO I.RPM
3.20 +0080
3.20 +0080
» MAINTENANCE STATUS =¦=¦=
TIM DWL PCV A.CL
-08 -01 OK BAD
-08 -01 OK BAD
CHOKE A.PMP MISF. NOXC
OK OK NO NA
OK OK NO NA
IDLE INSPECTION
STATION NO. 4
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
265
265
2500HC
65
65
I. CO
3.10
2500CO
2.00
3.10 2.00
FAILURE
PASS
PASS
COST
5.00
5.00 TOT.
***************************
TEST NO:C0649
AS RECEIVED FROM OWNER ***************************
10/16/73 BAR:24.92 DB:70 WB:53
REL.HUM:33.6% NOX COR: .872
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.53
5.. 60
5.01
5.63
91.9
106.4
72. 1
93.9
646.5
595.4
524.0
586.3
5.51
2.91
4.50
3.90
10.97
11.41
13.63
11.85
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
3952
3876
3357
3.53
2.65
1.49
97
1565.
2648
401
437
356
560
510
330
2500 RPM
270
3.80
2.70
1.50
3.80
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0649
10/16/73 BAR:24.92 DB:70 WB:53
REL.HUM:33.6% NOX COR: .872
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.53
5.60
5.01
5.63
91.9
106.4
72. 1
93.9
646.5
595.4
524.0
586.3
5.51
2.91
4.50
3.90
10.97
11.41
13.63
11.85
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3952
3876
3357
3.53
2.65
1.49
97
1565
2648
401
437
356
560
510
330
270
3.80
2.70
1.50
3.80
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 234
1968 MERC COUG 302 3500LBS
8CYL 4BBL AUTOMATIC 074758 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
FROM OWNER
FROM INSP.
usiaaainaraiau MAINTENANCE STATUS ===
I. CO I.RPM TIM DWL PCV A.CL
6.00 +0050 +11 +03 OK BAD
4.90 +0045 400 +03 OK OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 1
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
****
750
2500HC
260
90
I. CO
5.40
2.60
25O0CO
1.40
1.00
FAILURE
BOTH
HC
COST
0.00
51.61
200.00 EST.
51.61 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0661
10/17/73 BAR:24.86 DB:69WB:50
REL.HUM:26.4% NOX COR: .836
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.16
7.38
5.25
6.33
66.5
59.3
39.5
55.3
421. 1
408.0
357.7
396.8
4.63
2.96
4.94
3.86
16.43
16.97
20.40
17.68
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
9075
4130
3590
6.62
0.78
0.86
50
3041
4267
1739
514
439
****
600
490
370
6.60
0.90
0.90
1. 10
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0684
10/18/73 BAR:24.86 DB:83 WB:56
REL.HUM:17.9% NOX COR: .845
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.48
3.83
3.82
3.96
54.5
76.2
47.7
63.8
452.3
493. 1
426.2
466.0
3.46
2.34
3.62
2.93
16.13
14.25
17.35
15.39
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3374
3208
2996
5.79
1.40
0.98
80
1784
2822
403
481
463
200
210
165
100
4.60
1.20
0.75
1.80
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 235
1965 BUIC WILD 425 4500LBS
8CYL 4BBL AUTOMATIC 078046 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
FROM OWNER
FROM INSP.
»=======«==.=,===»=•= MAINTENANCE STATUS ===
I.CO I.RPM TIM DHL PCV A.CL
11.10 -0060 +10 +00 OK BAD
11.00 -0060 +22 +00 OK BAD
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
STATION NO.
IDLE INSPECTION
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
1400
500
*****
8.00
BOTH
4.50
AFTER I.RPM ADJUST
1300
500
*****
7.80
BOTH
1.50
AFTER I.MX/TM ADJ1
****
700
5.00
7.60
BOTH
1.50
AFTER I.MX/TM ADJ2
1200
1800
2.00
7.00
BOTH
4.50
REPAIRS
41.42
FINAL INSPECTION
****
****
*****
6.40
BOTH
45.00
53.42 TOT.
A************************** as RECEIVED FROM OWNER ***************************
TEST NO:C0662
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
10/17/73 BAR:24.86 DB:69 WB:50
REL.HUM:26.4% NOX COR: .836
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
19.21
30.27
17.59
24.44
201.6
263.7
219.5
238.5
459. 1
398.6
374. 1
404.5
2.93
0.96
1.41
1.50
10.64
9.80
11.49
10.40
16320
6929
5977
11.88
8.16
6.97
11
327
790
1800
993
796
****
1440
1040
****
*****
9.00
7.40
9.80
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0687
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
10/18/73 BAR:24.82 DB:71 WB:52
REL.HUM:28.3% NOX COR: .853
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
21.80
34.57
19.07
27.60
202.2
272.6
237.8
248.2
482.2
426.0
441.7
442. 1
3.83
1.20
2.04
1.98
10.25
9.24
10. 17
9.69
16549
6568
6059
12.62
7.71
7.48
8
417
762
****
799
728
****
620
530
720
*****
6.90
6.70
7.30
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 236
1965 CHEV IMPA 327 4000LBS
8CYL 4BBL AUTOMATIC 061259 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
¦= MAINTENANCE STATUS
FROM OWNER
I. CO
8.20
I.RPM
-0010
TIM
+02
DWL
+01
PCV
OK
A.CL
BAD
CHOKE A.PMP MISF.
OK
NA
NO
NOXC
NA
FROM INSP. 0.16
+0000
+00 +00
OK
OK OK
NA
NO NA
STATION NO. 7
I. HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
640
660
6.20
6. 10
BOTH
2.50
AFTER I.RPM ADJUST
640
660
6.20
6. 10
BOTH
2.50
AFTER I.MX/TM ADJ1
400
400
2. 10
2. 20
PASS
2.50
AFTER I.MX/TM ADJ2
REPAIRS
2.50
FINAL INSPECTION
400
400
2.10
2. 20
PASS
10.00 TOT.
* A A A A AAA A AAA A AAA 4c AAA A AAA AAA
AS RECEIVED
FROM OWNER ***************************
TEST NO:C0663
10/17/73 BAR:24.86 DB:71 WB:51
REL.HUM:25.2% NOX COR: .838
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
13.24
10. 28
9.29
10.62
240.1
220.0
162.5
208.3
423.6
413.9
392.5
410.0
0.89
0.67
1.44
0.93
10.57
11.24
13. 15
11.56
7311
5017
6232
9.24
4.64
9.23
46
764
225
858
641
833
385
800
950
920
8.40
4.60
9.30
6.80
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0690
10/18/73 BAR:24.83 DB:72 WB:52
REL.HUM:26.2% NOX COR: .847
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
9.39
6. 20
6.25
6.88
202.7
131.5
132.5
146.7
462.9
453.3
413.2
444.2
1.21
0.92
1.53
1. 15
10.98
13.10
13.89
12.79
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3420
4113
3911
0.20
5.05
5.42
126
636
706
481
564
544
285
320
260
400
0. 13
4.40
4.60
2.20
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 237
1968 CADI FLEE 472 5000LBS
8CYL 4BBL AUTOMATIC 065733 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
FROM OWNER
FROM INSP.
==«=.=== MAINTENANCE STATUS =•==
I.CO I.RPM TIM DWL PCV A.CL
0.35 +0090 +00 +00 OK BAD
0.35 +0090 +00 +00 OK BAD
ssaaasaasssaaaaaaasasaaaaa
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 9
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I. HC
90
90
2500HC
50
50
I. CO
2.30
2500CO
0.70
2.30 0.70
FAILURE
PASS
PASS
COST
4.00
4.00 TOT.
k-kkk'kkkkitk'kk'k'k kkickk ********
TEST NO:C0677
AS RECEIVED FROM OWNER ***************************
10/18/73 BAR:24.89 DB:73 WB:53
REL.HUM:27.0% NOX COR: .855
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
19 75 COMPOSITE
5.35
4.57
3.77
4.51
142.9
115.3
106.2
118.6
661.3
664.2
502.9
618.8
1.72
1.17
1.40
1.35
9.86
10.36
13.06
10.87
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
1039
3267
4824
0.48
2.86
10.03
101
682
141
272
540
700
40
190
280
0.35
2.00
2.00
2500 RPM
30
0.53
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0677
10/18/73 BAR:24.89 DB:73 WB:53
REL.HUM:27.0% NOX COR: .855
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.35
4.57
3.77
4.51
142.9
115.3
106.2
118.6
661.3
664.2
502.9
618.8
1.72
1.17
1.40
1.35
9.86
10. 36
13.06
10.87
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
1039
3267
4824
0.48
2.86
10.03
101
682
141
272
540
700
40
190
280
30
0.35
2.00
2.00
0.53
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 238
1969 DODG CORO 318 3500LBS
8CYL 2BBL AUTOMATIC 051016 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
MAINTENANCE STATUS
FROM OWNER
FROM INSP.
I. CO
5.40
5.70
I.RPM
-0050
+0100
TIM DWL
+02 +00
+02 +00
PCV
OK
OK
A.CL
OK
OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 10
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
450
450
350
2500HC
320
180
200
I. CO
2.80
1.50
2.00
2500CO
1.50
1.40
1.50
FAILURE
HC
HC
HC
COST
1.50
1.50
17.32
20.32 TOT.
*************************** as RECEIVED FROM OWNER ***************************
TEST NO:C0674
10/18/73 BAR:24.89
REL.HUM:30.4%
DB:70 WB:52
NOX COR: .858
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
10.51
9.88
8.49
9.63
125.0
118.8
102.9
115.7
453.0
464.4
454.7
459.3
3.92
2.90
3.63
3.32
13.04
13.05
13.84
13.26
7828
5499
4954
5.77
3.52
4.22
69
1417
1198
1478
782
670
1260
540
385
400
4.80
3.00
3.40t,
4.30
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0706
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
10/19/73 BAR:24.86 DB:70 WB:50
REL.HUM:24.2% NOX COR: .830
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
10.78
9.83
6.31
9.05
152.1
124.5
69.6
115.0
460.4
486.3
372.3
449.2
3.04
3. 17
3.64
3.27
12. 14
12.49
17.75
13.52
6611
5320
4825
6.49
2.83
3.92
75
1813
1424
1168
831
683
820
520
375
370
5.50
2.30
3.40
3.60
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 239
1968 VOLK SEDA 91 2000LBS
4CYL 1BBL 4 SPEED 084309 MILES
IDLE INSPECTION ONLY
HAS: EMC, NO EVC, NO PCV
ssssa
133393333
3333333
S3333333
== MAINTENANCE STATUS
====•
3333933
3 333333
3333333
33333
I. CO
I.RPM
TIM DWL PCV A
.CL
CHOKE
A.PMP
MISF.
NOXC
FROM
OWNER
6.94
+0010
+00 +00 NA
OK
OK
NA
YES
NA
FROM
INSP.
0.70
+0000
-K)0 +00 NA
OK
OK
NA
NO
NA
IDLE INSPECTION
STATION NO. 5
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
200
180
180
2500HC
210
160
160
I.CO 2500CO
4.00 4.40
1.10 3.60
1.10
3.60
FAILURE
CO
PASS
PASS
COST
5.50
0.00
5.50 TOT.
A******************* *******
TEST NO:C0664
AS RECEIVED FROM OWNER ***************************
10/17/73 BAR:24.90 DB:74 WB:53
REL.HUM:25.0% NOX COR: .849
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.63
3.79
6.30
4.66
93.2
106.4
99.5
101.7
247.4
254.3
197.4
237. 1
1.28
0.78
0.73
0.87
21.80
20.54 •
23.83
21.64
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
5081
3799
2722
7.78
8.92
4.93
55
247
1387
401
434
360
400
410
290
720
7.70
9.00
4. 70
*****
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0707
10/19/73 BAR
REL.HUM:
:24.85
24.2%
DB: 70
NOX COR
WB: 50
: .830
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.77
4.09
3.82
4.16
78.9
54.4
62.5
61.8
267.8
295.5
240.3
274.4
2.20
1.97
1.82
1.98
21.88
22.61
25.41
23. 16
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
3411
2926
2835
0.78
3.09
4.59
73
1283
1521
430
402
411
250
170
185
0.70
2.80
4.00
2500 RPM
260
2.90
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 240
1965 CHEV CHEV 230 3000LBS
6CYL 1BBL AUTOMATIC 071640 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
laasaaaaaaaaaaaa
FROM OWNER
FROM INSP.
I.CO I.RPM
3.80 +0000
3.80 +0000
« MAINTENANCE STATUS -==
TIM DWL PCV A.CL
+00 -03 OK BAD
+00 -03 OK BAD
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 8
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
280
2500HC
140
280 140
I. CO 2500CO FAILURE COST
2.20 2.00 PASS 3.50
2.20 2.00
PASS
3.50 TOT.
************** ***** * *** ****
TEST NO:C0688
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
AS RECEIVED FROM OWNER ***************************
10/18/73 BAR:24.83 DB:71 WB:52
REL.HUM:28.3% NOX COR: .852
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
19.74
5.60
5.33
8.48
224.3
87.6
102.6
120.4
365.5
370.0
319.4
355.0
2. 18
2.58
2.82
2.56
11.41
16.95
17.90
15.60
5232
4385
5829
3.92
3.59
11.16
91
1983
199
677
583
737
490
320
440
170
3.50
3.30
*****
1.70
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0688
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
10/18/73 BAR:24.83 DB:71 WB:52
REL.HUM:28.3% NOX COR: .852
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
19.74
5.60
5.33
8.48
224.3
87.6
102.6
120.4
365.5
370.0
319.4
355.0
2.18
2.58
2.82
2.56
11.41
16.95
17.90
15.60
5232
4385
5829
3.92
3.59
11.16
91
1983
199
677
583
737
490
320
440
170
3.50
3.30
*****
1.70
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 241
1965 CHEV IMPA 396 3500LBS
8CYL 4BBL AUTOMATIC 101402 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
MAINTENANCE STATUS
FROM OWNER
FROM INSP.
I. CO
11.10
10.30
I. RPM
+0225
+0225
TIM DWL
+02 -08
+02 -08
PCV
OK
OK
A.CL
BAD
BAD
CHOKE
OK
OK
A.PMP
NA
NA
MISF.
YES
NO
NOXC
NA
NA
IDLE INSPECTION
STATION NO. 4
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1"
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
****
****
2500HC
•kick*
****
I.CO 2500CO
***** 6.00
*****
6.00
FAILURE
BOTH
BOTH
COST
5.00
5.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0691
10/19/73 BAR:24.86 DB:69 WB:52
REL.HUM:32.8% NOX COR: .864
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
24.68
21. 12
14.35
19.99
254. 1
393.6
231.5
319.4
503.8
542.0
459.4
511.1
1.00
0.70
0.95
0.83
9.07
7.26
10.25
8. 28
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
11885
5113
5432
12.80
6.72
4.71
27
215
631
1259
536
758
650
260
450
250
8.60
4.80
3.10
5.90
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0714
10/22/73 BAR:24.83 DB:76 WB:52
REL.HUM:18.8% NOX COR: .825
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
47.02
46.83
35.23
43.65
244.1
274.6
211.2
250.6
523.0
523.6
417.5
494.0
1.31
1.59
1.00
1.36
8.44
8.07
10.34
8.68
15150
10009
9879
12.53
5.33
5.11
29
376
507
2086
1999
1991
****
****
****
****
9.20
4.20
4.00
4.90
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 242
1970 FORD MUST 302 3500LBS
8CYL 2BBL AUTOMATIC 016785 MILES
COMBINATION RETROFIT
HAS: EMC, NO EVC, PCV
FRCM OWNER
FROM INSP.
msaaaaasaaaaaaa MAINTENANCE STATUS ===
I. CO I.RPM TIM DWL PCV A.CL
0.30 -0055 +00 -06 BAD OK
0.22 -0055 +00 +01 BAD BAD
CHOKE A.PMP MISF. NOXC
OK NA YES NA
OK NA YES NA
STATION NO. 8
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC 2500HC
840 250
400 190
270 170
270
170
I. CO
0.20
0.20
0.40
0.40
2500CO
0.90
0.50
0.70
0.70
FAILURE
HC
NO ANS.
PASS
PASS
COST
3.50
2.00
2.50
8.00 TOT.
***************************
TEST N0:C0692
AS RECEIVED FROM OWNER ***************************
10/19/73 BAR:24.85 DB:70 WB:50
REL.HUM:24.2% NOX COR: .830
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.09
5.31
5.48
5.73
80.4
44.7
38.6
50.5
472.0
446.9
419.4
444.5
4.23
2.76
4.18
3.46
14.35
16.68
17.90
16.44
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
6276
4234
4001
0.38
1.37
1.59
100
2658
3132
1051
611
546
640
310
240
190
0.23
1.00
1. 20
1.30
**********************AAA
AS RECEIVED FROM
INSPECTION ************************
TEST N0:C0712
10/22/73 BAR
REL.HUM:
:24.82
27.4%
DB: 70
NOX COR:
WB: 51
.844
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.64
4.84
6.56
5.69
85.6
52.9
44.5
57.4
500.8
457.0
405.5
451.9
3.75
2.47
3.99
3.16
13.57
16.03
17.95
15.90
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
3266
3366
3374
0.26
1. 13
1.51
121
1947
2726
431
477
476
250
290
275
0.23
1. 10
1.30
2500 RPM
180
1.60
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 243
1969 PONT CATA 400 4000LBS
8CYL 2BBL AUTOMATIC 057823 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
MAINTENANCE STATUS
Baaasss:
ssasassz
I. CO I.RPM TIM DWL PCV A.CL CHOKE A. PMP MISF. NOXC
FROM OWNER 3.90 -0110 -10 +0 7 OK BAD OK NA NO NA
FROM INSP. 0.73 -0090 -K)5 -07 OK BAD OK NA YES NA
IDLE INSPECTION
STATION NO. 7
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
460
480
380
380
2500HC
480
460
360
360
I. CO
4.10
4.30
3.10
3.10
2500CO
4. 20
4. 10
3.00
3.00
FAILURE
BOTH
BOTH
PASS
PASS
COST
2.50
2.50
0.00
10.00
15.00 TOT.
* ************** A*** A A**** * **
TEST NO:C0695
AS RECEIVED FROM OWNER ***************************
10/19/73 BAR:24.85 DB:70 WB:50
REL.HUM:24.2% NOX COR: .830
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.70
4.42
4.53
4.93
144.9
83.4
83.3
96.2
633.2
632.1
557.2
611.6
2.23
2.07
2.50
2.22
10. 10
11.46
12.68
11.44
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3825
3150
2408
4.46
2.07
0.69
102
807
1652
480
409
339
175
120
60
100
2. 20
1. 10
0.30
1.30
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:CO719
10/22/73 BAR
REL.HUM:
: 24.83
13.9%
DB: 81
NOX COR
WB: 53
: .813
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.77
4.88
4.74
5.24
106.0
36.5
35.5
50.7
557.4
505.0
458.1
502.9
4.56
3.68
5.40
4.34
11.95
15.41
16.84
14.86
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4472
3949
3448
0.86
1.00
0.42
165
2706
4225
603
551
495
380
320
200
330
0.80
1.00
0.35
0.65
AUTOMOTIVE
TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 245
1968 FORD FAIR 289 3500LBS
8CYL 2BBL 3 SPEED 077348 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
MAINTENANCE STATUS
FROM OWNER
FROM INSP.
I. CO
3.56
7.68
I.RPM
-0115
-0005
TIM DWL
+06 +00
+02 +00
PCV A.CL
OK BAD
OK BAD
CHOKE A.PMP MISF. NOXC
OK OK YES NA
OK OK YES NA
STATION NO.
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
780
680
3.40
0.20
HC
4.50
AFTER I.RPM ADJUST
500
620
2.40
0.20
HC
1.50
AFTER I.MX/TM ADJ1
380
300
4.20
2.00
BOTH
1.50
AFTER I.MX/TM ADJ2
280
100
3.60
0.30
PASS
3.00
REPAIRS
FINAL INSPECTION
280
100
3.60
0.30
PASS
10.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0696
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
10/19/73 BAR:24.86 DB:74 WB:52
REL.HUM:22.3% NOX COR: .836
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
9.52
7.34
6.36
7.53
119.5
88.7
76.1
91.7
377.8
449.2
361.4
409.9
1.48
1.45
1.96
1.60
14.95
14.55
17.77
15.42
5701
3322
4059
4.24
1.86
3.02
39
1620
1739
456
513
618
250
160
235
115
3.00
1.20
2.00
0.70
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0718
10/22/73 BAR:24.83 DB:81 WB:53
REL.HUM:13.9% NOX COR: .813
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
12.54
13.71
9. 17
12.21
151.4
125.5
97.5
123.2
468.3
459.6
406.2
446.6
1.79
1.63
2.55
1.92
11.94
12.72
15. 14
13. 12
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
13179
4612
4567
10. 18
1.39
2.63
23
1891
1693
1957
708
679
1300
380
400
600
7.20
1.00
2.00
0.70
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 246
1968 OLDS DELT 455 4500LBS
8CYL 2BBL AUTOMATIC 114750 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
3S33S
:a==333S!3
S33=3S3
3=333333
=¦=> MAINTENANCE STATUS
sess;
I. CO
I.RPM
TIM DWL PCV A,
.CL
FROM
OWNER
6.80
+0015
+02 -03 OK
OK
FROM
INSP.
6.80
+0015
+02 -03 OK
OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
STATION NO. 10
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC
230
2500HC
100
230 100
I. CO
3.00
2500CO
1.90
3.00 1.90
FAILURE COST
PASS 1.50
PASS
1.50 TOT.
***************************
AS i
RECEIVED
FROM OWNER
***************************
TEST NO:C0693
10/19/73 BAR
:24.86
DB : 70
WB: 52
REL.HUM:
30.5%
NOX COR:
: .858
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
6.62
72.0
662.6
4.75
11. 18
COLD STABILIZED
5.65
82.7
564.0
2.46
12.51
HOT TRANSIENT
4.52
60.0
514.4
3.47
14. 29
1975 COMPOSITE
5.54
74. 1
570.9
3.22
12.64
IDLE KEYMODE
6943
8.40
55
720
420
6.20
LOW CR. KEYMODE
3210
2.79
1228
405
160
2. 10
HI. CR. KEYMODE
3099
1.86
2688
389
130
1.50
2500 RPM
240
3. 10
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0693
10/19/73 BAR:24.86 DB:70 WB:52
REL.HUM:30.5% NOX COR: .858
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.62
5.65
4.52
5.54
72.0
82.7
60.0
74. 1
662.6
564.0
514.4
570.9
4.75
2.46
3.47
3.22
11. 18
12.51
14.29
12.64
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
6943
3210
3099
8.40
2.79
1.86
55
1228
2688
720
405
389
420
160
130
240
6.20
2. 10
1.50
3. 10
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 247
1968 FORD GALA 390 4000LBS
8CYL 2BBL AUTOMATIC 046034 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
issssaaos
FROM OWNER
FRCM INSP.
¦==»=¦======*===*"»= MAINTENANCE STATUS ="*=
I.CO I.RPM TIM DWL PCV A.CL
5.50 +0010 +09 +00 OK BAD
5.50 +0010 +09 +00 OK BAD
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 10
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
210
210
2500HC
80
80
I. CO
3.80
2500CO
0.40
3.80 0.40
FAILURE
PASS
PASS
COST
1.50
1.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0694 10/19/73 BAR:24.86 DB:70 WB:50
REL.HUM:24.2% NOX COR: .830
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
7.12
65.6
602.5
7.15
12. 23
COLD STABILIZED
6.51
100.6
520.8
5.13
12.73
HOT TRANSIENT
5.74
54.4
503.7
7.11
14.66
1975 COMPOSITE
6.43
80.4
533.2
6.10
13. 10
IDLE KEYMODE
4569
6.31
65
502
220
6.00
LOW CR. KEYMODE
3535
0.25
3298
552
180
0.20
HI. CR. KEYMODE
3180
0.25
4275
472
115
0. 16
2500 RPM
126
0.60
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0694
10/19/73 BAR:24.86 DB:70 WB:50
REL.HUM:24.2% NOX COR: .830
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.12
6.51
5.74
6.43
65.6
100.6
54.4
80.4
602.5
520.8
503.7
533.2
7.15
5.13
7.11
6.10
12.23
12.73
14.66
13.10
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4569
3535
3180
6.31
0.25
0.25
65
3298
4275
502
552
472
220
180
115
126
6.00
0.20
0. 16
0.60
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 248
1969 PONT LEMA 350 4000LBS
8CYL 2BBL AUTOMATIC 027997 MILES
COMBINATION RETROFIT
HAS: EMC, NO EVC, PCV
aaasazaaaaaaaaBaassaaaaaaasaaa MA1NTENANC E STATUS ssasaaaaaaaasassasssssssaaaoas
I.CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 0-38 -0130 -04 +04 OK OK OK NA NO NA
FROM INSP. 0.38 -0130 -04 +04 OK OK OK NA NO NA
STATION NO.
IDLE INSPECTION
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
175
175
2500HC
90
90
I.CO 2500CO
0.20 0.55
0.20 0.55
FAILURE COST
PASS 5.00
PASS
5.00 TOT.
***************************
AS :
RECEIVED
FROM OWNER
***************************
TEST NO:CO709
10/22/73 BAR
: 24.77
DB: 70
WB: 50
REL.HUM:
24.3%
NOX COR:
.831
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
8.34
131.8
567.4
4.51
11.12
COLD STABILIZED
4.75
35.0
582.2
4.83
13.65
HOT TRANSIENT
5.08
59.7
494.0
5.11
14.75
1975 COMPOSITE
5.59
62. 1
554.6
4.84
13.30
IDLE KEYMODE
1739
0.42
91
251
50
0. 13
LOW CR. KEYMODE
3765
1.65
2669
523
110
0.50
HI. CR. KEYMODE
4529
7.25
506
608
120
7. 10
2500 RPM
45
0.23
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:CO709
10/22/73 BAR:24.77 DB:70 WB:50
REL.HUM:24.3% NOX COR: .831
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
8.34
4.75
5.08
5.59
131.8
35.0
59.7
62. 1
567.4
582.2
494.0
554.6
4.51
4.83
5.11
4.84
11. 12
13.65
14.75
13.30
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
1739
3765
4529
0.42
1.65
7.25
91
2669
506
251
523
608
50
110
120
45
0. 13
0.50
7. 10
0.23
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 249
1971 PLYM FURY 383 4000LBS
8CYL 4BBL AUTOMATIC 030259 MILES
SEA LEVEL RETROFIT
HAS: EMC, NO EVC, PCV
FROM OWNER
FROM INSP.
oasauixuasiim MAINTENANCE STATUS =="
I. CO I.RPM TIM DWL PCV A.CL
5.40 -0110 +04 +00 OK OK
5.40 -0110 +04 +00 OK OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
STATION NO. 3
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
300
300
2500HC
300
300
I. CO
2.00
2.00
2500CO
2.50
2.50
FAILURE
PASS
PASS
COST
0.00
6.00
6.00 TOT.
***************************
AS RECEIVED FROM
: OWNER
* * A * * * sk * it it it * it it it it it it it * * it * it it it *
TEST NO:C0710
10/22/73 BAR
:24.77
DB :70
WB: 50
REL.HUM:
24.3%
NOX COR
: .831
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
11.95
199.3
548.2
2.18
9.90
COLD STABILIZED
6.75
157.5
559.3
1.13
10.75
HOT TRANSIENT
5.61
126.0
480.8
2. 10
12.79
1975 COMPOSITE
7.52
157.5
535.2
1.62
11.05
IDLE KEYMODE
5950
5.93
44
535
365
4.60
LOW CR. KEYMODE
4087
4.29
657
459
275
3.40
HI. CR. KEYMODE
3766
4.63
1167
425
210
3.70
2500 RPM
195
3.90
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0710
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
10/22/73 BAR:24.77 DB:70 WB:50
REL.HUM:24.3% NOX COR: .831
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
11.95
6.75
5.61
7.52
199.3
157.5
126.0
157.5
548.2
559.3
480.8
535.2
2. 18
1.13
2.10
1.62
9.90
10.75
12.79
11.05
5950
4087
3766
5.93
4.29
4.63
44
657
1167
535
459
425
365
275
210
195
4.60
3.40
3.70
3.90
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 250
1970 CHEV CAME 350 3500LBS
8CYL 2BBL 4 SPEED 047370 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
FROM OWNER
FROM INSP.
,====.=.========, MAINTENANCE STATUS »=
I. CO I.RPM TIM DWL PCV A.CL
6.40 -0200 +00 +05 OK OK
5.40 -0170 -04 +04 OK OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. -7
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
460
420
7.20
6.20
BOTH
2.50
AFTER I.RPM ADJUST
460
420
7.20
6.20
BOTH
2.50
AFTER I.MX/TM ADJ1
300
300
3.40
3.30
PASS
2.50
AFTER I.MX/TM ADJ2
REPAIRS
2.50
FINAL INSPECTION
300
300
3.40
3.30
PASS
10.00 TOT.
***************************
AS RECEIVED
FROM OWNER ***************************
TEST NO:C0727
10/23/73 BAR:24.68 DB:72 WB:51
REL.HUM:23.4% NOX COR: .834
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
11.13
6.36
5.52
7.13
101.8
87.5
60.7
83. 1
476.3
553.1
428.8
502.5
3.49
2.06
3.46
2. 75
13.26
12.53
16.44
13.59
4402
2790
2911
6.56
1.07
2.45
51
2086
2200
387
371
414
255
190
220
90
5.40
0.90
2.20
1.20
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
lEST NO:C0746
10/24/73 BAR:24.64 DB:71 WB:50
REL.HUM:22.4% NOX COR: .827
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
8.63
6.32
5.03
6.45
105.3
71.6
48.0
72. 1
602.5
584.4
487.0
561.1
4.02
2.32
3.88
3.11
11.20
12.42
15.40
12.82
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
6296
3823
3601
5.45
1.24
2.93
62
1975
2094
724
465
430
380
200
190
180
4.60
1.70
2.60
1. 10
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 251
1973 CHEV IMPA 350 4000LBS
8CYL 4BBL AUTOMATIC 006702 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, EVC, PCV
FROM OWNER
FRGtl INSP.
I.CO I.RPM
1.40 +0020
1.40 +0020
« MAINTENANCE STATUS «=
TIM DWL PCV A.CL
+02 +02 OK BAD
+02 +02 OK BAD
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
STATION NO.
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
60
60
2500HC
40
40
I. CO
1.30
2500CO
0.35
1.30 0.35
FAILURE COST
PASS 5.50
PASS
5.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0724
10/23/73 BAR:24.70 DB : 70 WB:50
REL.HUM:24.4% NOX COR: .832
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
3.84
2.92
3.04
3.15
88.5
64.7
69.8
71. 1
606.0
644.4
492.2
594. 1
1.83
1.33
1.48
1.47
11.76
11.79
14.56
12.44
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
1061
2337
2203
1.79
1.63
1.57
53
649
1356
220
407
380
50
155
125
40
1.40
I. 30
1.25
0.40
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0724
10/23/73 BAR
REL.HUM:
:24.70
24.4%
DB: 70
NOX COR:
WB: 50
: .832
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
3.84
2.92
3.04
3.15
88.5
64.7
69.8
71.1
606.0
644.4
492.2
594. 1
1.83
1.33
1.48
1.47
11.76
11.79
14.56
12.44
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
1061
2337
2203
1.79
1.63
1.57
53
649
1356
220
407
380
50
155
125
40
1.40
1.30
1.25
0.40
AUTOMOTIVE
TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 252
1973 OLDS OMEG 350 3500LBS
8CYL 4BBL 3 SPEED 009599 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, EVC, PCV
FROM OWNER
FROM INSP.
»========= MAINTENANCE STATUS =«=.»======
I. CO I.RPM
0.42 +0110
0.42 +0110
TIM DWL PCV A.CL
-02 -02 BAD OK
-02 -02 BAD OK
CHOKE A.PMP MISF. NOXC
OK NA NO BAD
OK NA NO BAD
IDLE INSPECTION
STATION NO. 9
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
200
200
2500HC
100
100
I. CO
0.40
0.40
2500CO
1.00
1.00
FAILURE
PASS
PASS
COST
0.00
4.00
4.00 TOT.
* ****************** ** A A A* A *
TEST NO:C0726
AS RECEIVED FROM OWNER ***************************
10/23/73 BAR:24.68 DB:70 WB:48
REL.HUM:18.4% NOX COR: .807
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.66
3.74
4.24
4.07
82.8
79.7
70.8
77.9
577.3
621.0
464.5
568.4
1.49
0.91
1. 10
1.08
12.33
11.75
15. 12
12.66
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
1464
2092
2062
0.41
1.34
0.65
69
485
1665
218
275
280
75
140
120
95
0.48
1.30
0.58
1.50
*************************
AS RECEIVED FROM
INS PECT ION ************************
TEST NO:C0726
10/23/73 BAR
REL.HUM:
:24.68
18.4%
DB: 70
NOX COR:
WB:48
.807
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.66
3.74
4.24
4.07
82.8
79.7
70.8
77.9
577.3
621.0
464.5
568.4
1.49
0.91
1.10
1.08
12.33
11.75
15. 12
12.66
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
1464
2092
2062
0.41
1.34
0.65
69
485
1665
218
275
280
75
140
120
95
0.48
1.30
0.58
1.50
AUTOMOTIVE
TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 254
1970 FORD MUST 302 3000LBS
8CYL 2BBL AUTOMATIC 036423 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
FROM OWNER
FROM INSP.
•================, MAINTENANCE STATUS =¦==
I.CO I.RPM TIM DWL PCV A.CL
4.30 -0050 +04 +07 OK BAD
4.30 -0050 +04 +07 OK BAD
saaaaaas
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 8
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
200
2500HC
190
200 190
I. CO
0.60
2500C0
0.90
0.60 0.90
FAILURE COST
PASS 3.50
PASS
3.50 TOT.
* k k * * k k k * k k k k k k k k k k k k k k k k k k
TEST NO:C0730
AS RECEIVED FROM OWNER ***************************
10/23/73 BAR:24.64 DB:80 WB:51
REL.HUM:10.9% NOX COR: .794
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.21
4.88
7.75
6. 17
98.4
90.7
77.2
88.5
479.9
494.9
411.5
468.6
3.00
1.44
2.69
2.11
13.55
13.64
15.98
14.20
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4870
4829
4716
3.69
3.55
3.05
112
768
1803
581
700
687
300
380
360
340
3.40
3. 20
2.60
3.40
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0730
10/23/73 BAR:24.64
REL.HUM:10.9%
DB: 80
NOX COR
WB: 51
: .794
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.21
4.88
7.75
6.17
98.4
90.7
77.2
88.5
479.9
494.9
411.5
468.6
3.00 .
1.44
2.69
2. 11
13.55
13.64
15.98
14.20
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4870
4829
4716
3.69
3.55
3.05
112
768
1803
581
700
687
300
380
360
340
3.40
3.20
2.60
3.40
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 255
1972 CHEV NOVA 307 3000LBS
8CYL 2BBL AUTOMATIC 032867 MILES
COMBINATION RETROFIT
HAS: EMC, EVC, PCV
*= MAINTENANCE STATUS
FROM OWNER
FROM INSP.
I. CO
6.50
1.50
I.RPM
-0040
+0180
TIM DWL
+00 +00
+00 +00
PCV
OK
OK
A.CL
OK
OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 10
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
440
320
320
2500HC
250
200
200
I.CO 2500CO
4.60 1.00
0.40 0.80
0.40 0.80
FAILURE
BOTH
NO ANS.
PASS
COST
1.50
1.50
3.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0723
10/23/73 BAR:24.70 DB:70 WB:50
REL.HUM:24.4% NOX COR: .832
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.79
3.70
3.27
3.81
56.0
36.5
33.3
39.7
421.1
399.9
359.2
393.0
3.83
2.07
3.56
2.85
16.99
18.99
21. 11
19.05
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
5604
3445
3162
6.83
0.53
1.82
48
2926
2137
752
513
451
575
290
240
190
5.60
0.43
1.60
1.40
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0752
10/24/73 BAR
REL.HUM:
:24.50
24.4%
DB: 76
NOX COR:
WB: 54
.857
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.27
3. 19
2.64
3.26
67.2
23.5
37.4
36.5
468.7
520.8
372.9
468.9
3.43
2.86
3. 14
3.05
15. 15
15.68
20.24
16.60
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
3479
3440
3340
0.86
0.66
1.99
231
2246
2176
528
479
460
320
260
280
1. 20
0.40
1.60
2500 RPM
160
0.60
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 256
1966 OLDS CUTL 330 3500LBS
8CYL 2BBL AUTOMATIC 053077 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
aaaaa
laaaassa
aaaaaaa
aaaaaaaa
— MAINTENANCE STATUS
am;
I. CO
I. RPM
TIM DWL PCV A
.CL
FROM
OWNER
2.56
-0200
+00 +00 OK
OK
FROM
INSP.
1.50
+0125
+00 +00 OK
OK
CHOKE
OK
OK
A.PMP
NA
NA
MISF.
YES
YES
NOXC
NA
NA
STATION NO.
— IDLE INSPECTION
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
1500
****
3.00
3.60
HC
4.50
AFTER I.RPM ADJUST
1250
****
2.80
4.00
HC
1.50
AFTER I.MX/TM ADJ1
1060
****
0.30
4.20
HC
1.50
AFTER I.MX/TM ADJ2
****
****
0.20
3.00
HC
4.50
REPAIRS
33.70
FINAL INSPECTION
1500
1600
1.90
4.00
HC
50.00
45.70 TOT.
***************************
TEST NO:C0729
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
AS RECEIVED FROM OWNER ***************************
10/23/73 BAR:24.65 DB:78 WB:51
REL.HUM:13.5% NOX COR: .804
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
28.86
19. 16
15.89
20. 28
149.0
128.7
72.7
117.4
354.2
376.7
310.9
353.7
1.73
1. 14
2.09
1.52
13.10
13.92
18.73
14.79
9916
9479
9098
4.25
3.28
2.39
69
810
1569
2008
2128
2020
1120
****
2000
1950
2. 20
2.40
1.90
3.70
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:CO767
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
10/25/73 BAR:24.40 DB:69 WB:50
REL.HUM:26.8% NOX COR: .840
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
16.17
8.28
6.40
9.41
175.7
98.0
67.5
105.8
367.5
451.7
365.1
410.0
1.93
1.90
2.90
2. 18
12.82
14.10
18.12
14.70
9180
5318
4412
1.92
3.32
2.36
170
1063
2283
1811
801
606
1140
600
400
1280
1.40
2.80
2.00
3.80
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 257
1965 CHRY STAW 413 5000LBS
8CYL 4BBL AUTOMATIC 083241 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
====«==*=====»======="»=»======= MAINTENANCE STATUS ==="»====»====«*!»======»====
I.CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 2.50 +0100 +00 -15 OK BAD OK NA NO NA
FROM INSP. 2.50 +0100 +00 -15 OK. BAD OK NA NO NA
XDLE INSPECTION
STATION NO. 2
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
370
2500HC
260
370 260
I. CO 2500CO
5.20 4.40
5.20 4.40
FAILURE COST
PASS 5.50
PASS
5.50 TOT.
***************************
TEST NO:CO738
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
AS RECEIVED FROM OWNER ***************************
10/24/73 BAR:24.55 DB:69 WB:50
REL.HUM:26.1% NOX COR: .838
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
12. 18
7.57
11. 16
9.53
b54.5
127. 2
129.8
133.6
461.2
457.0
411.2
445.1
3.40
2.37
2.54
2.63
11.99
13.08
13.69
13.00
4532
4242
4267
2.68
3.31
4.28
49
1711
1797
507
582
538
300
350
275
275
2.60
2.70
3.40
3.20
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0738
10/24/73 BAR:24.55 DB:69 WB:50
REL.HUM:26.7% NOX COR: .838
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
12. 18
7.57
11. 16
9.53
154.5
127.2
129.8
133.6
461.2
457.0
411.2
445.1
3.40
2.37
2.54
2.63
11.99
13.08
13.69
13.00
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4532
4242
4267
2.68
3.31
4.28
49
1711
1797
507
582
538
300
350
275
275
2.60
2.70
3.40
3.20
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 258
1965 FORD THUN 390 5000LBS
8CYL 4BBL AUTOMATIC 083016 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
aasaa
!333SaS3
SaSB83 33SS
SS93S3S
»= MAINTENANCE STATUS
as:
I. CO
I.RPM
TIM DWL PCV A
.CL
FROM
OWNER
5.12
+0000
+00 +06 OK
OK
FROM
INSP.
5.70
+0000
+00 +05 OK
OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 1
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I. HC
350
240
240
2500HC
170
100
100
I. CO
7.10
1.50
1.90
2500C0
3. 10
1.50
1.50
FAILURE
CO
PASS
PASS
COST
2.50
2.00
4.50 TOT.
***************************
AS 1
RECEIVED :
FROM OWNER
&A&4 ***** ****** ************
TEST NO:C0739
10/24/73 BAR
:24.56
DB : 76
W B: 50
REL.HUM:
14.0%
NOX COR
: .802
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
9.94
142.3
599.1
3.68
10.43
COLD STABILIZED
7.53
169. 1
526.4
1.80
10.91
HOT TRANSIENT
5.73
145.4
467.9
1.88
12.46
1975 COMPOSITE
7.54
156.9
525.4
2.21
11. 19
IDLE KEYMODE
4494
5.16
74
436
280
4. 10
LOW CR. KEYMODE
3816
4.15
973
488
310
3.40
HI. CR. KEYMODE
3504
3.99
1327
438
240
3.20
2500 RPM
180
3.80
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0762
10/25/73 BAR:24.61 DB:72 WB:54
REL.HUM:32.4% NOX COR: .879
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
8.97
7.29
11.79
8.89
141. 1
174.3
174.7
167.5
567.6
568.2
473.8
541.9
3.59
1.91
1.51
2.15
10.89
10. 29
11.33
10.69
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3927
3839
3536
5.70
5.48
5.47
85
596
759
461
491
449
380
360
270
220
4.80
1. 20
4.60
4.80
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 259
1966 VOLK FAST 97 2250LBS
4CYL 2BBL 4 SPEED 115141 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, NO PCV
ssssa
1333333
33333333
333333 3 33
== MAINTENANCE STATUS
==!
I. CO
I.RPM
TIM DWL PCV A,
.CL
FRCM
OWNER
5.40
+0050
+05 +00 NA
OK
FROM
INSP.
5.40
+0050
+05 +00 NA
OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
STATION NO. 5
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ 1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION —
I.HC
250
2500HC
220
250 220
I. CO
3.10
2500CO
0.55
3.10 0.55
FAILURE COST
PASS 5.50
PASS
5.50 TOT.
*************** ***** *** ****
TEST NO,:C0740
AS RECEIVED FROM OWNER ***************************
10/24/73 BAR:24.62 DB:79 WB:50
REL.HUM: 9.9% NOX COR: .787
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.74
4.14
3.60
4.74
140.9
64.3
66.5
80.9
287.9
234.6
194.8
234.7
1.06
1.33
1.40
1. 29
16.68
25.54
28.67
23.64
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
5466
3313
2955
6.26
3.49
3.14
49
1456
2251
581
424
377
335
230
180
4.80
3. 10
2.90
2500 RPM
240
3.20
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0740
10/24/73 BAR:24.62 DB:79 WB:50
REL.HUM: 9.9% NOX COR: .787
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.74
4.14
3.60
4.74
140.9
64.3
66.5
80.9
287.9
234.6
194.8
234.7
1.06
1.33
1.40
1.29
16.68
25.54
28.67
23.64
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
5466
3313
2955
6.26
3.49
3.14
49
1456
2251
581
424
377
335
230
180
240
4.80
3.10
2.90
3.20
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 260
1971 CHRY IMPE 440 5000LBS
8CYL 4BBL AUTOMATIC 023677 MILES
IDLE INSPECTION ONLY
HAS: EMC, NO EVC, PCV
FROM OWNER
FROM INSP.
:====»===»¦"===*=»===» MAINTENANCE STATUS ==¦=
I. CO I.RPM TIM DWL PCV A.CL
5.20 -0060 +08 +04 OK OK
5.20 -0060 +08 +04 OK OK
CHOKE A.PMP MISF. NOXC
OK NA YES NA
OK NA YES NA
IDLE INSPECTION
STATION NO. 3
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
120
2500HC
120
120 120
I. CO
2.00
2500CO
2.00
2.00 2.00
FAILURE COST
PASS 0.00
PASS
0.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0741
10/24/73 BAR:24.62 DB:74 WB:49
REL.HUM:14.4% NOX COR: .799
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
8.45
4.99
5.34
5.81
199.8
117.6
131.5
138.7
707.0
763.0
511.5
681.5
1.82
1.61
2.24
1.83
8.50
9.24
12. 12
9.71
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3386
3117
3360
5.73
2.62
4.60
77
701
666
303
309
320
175
130
130
140
4.50
2.20
3.70
3.00
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:CO741
10/24/73 BAR:24.62
REL.HUM:14.4%
DB : 74
NOX COR
WB:49
: .799
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
8.45
4.99
5.34
5.81
199.8
117.6
131.5
138.7
707.0
763.0
511.5
681.5
1.82
1.61
2.24
1.83
8.50
9.24
12. 12
9.71
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3386
3117
3360
5.73
2.62
4.60
77
701
666
303
309
320
175
130
130
140
4.50
2. 20
3.70
3.00
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 261
1969 FORD MUST 200 3000LBS
6CYL LBBL 3 SPEED 068680 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
MAINTENANCE STATUS
FROM OWNER
FROM INSP.
I.CO I.RPM
2.75 +0170
2.75 +0170
TIM DWL
-06 +03
-06 +03
PCV
BAD
BAD
A.CL
BAD
BAD
33333===:
CHOKE
OK
OK
A.PMP MISF. NOXC
NA YES NA
NA YES NA
STATION NO. 4
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
140
IDLE INSPECTION
2500HC
160
140 160
I.CO 2500CO
3.00 3.40
3.00 3.40
FAILURE COST
PASS 5.00
PASS
5.00 TOT.
*************************** as RECEIVED FROM OWNER ***************************
TEST NO:C0753
10/25/73 BAR:24.64 DB:69 WB:49
REL.HUM:23.4% NOX COR: .825
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.51
4.54
4.25
4.66
76.7
98.0
69.2
85.5
401.3
427.0
340.3
397.5
1.75
0.97
1.37
1.25
16.52
14.96
19.25
16.29
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3490
2306
4141
2.94
0.92
6.45
104
994
433
294
248
500
190
130
320
175
3. 10
0.90
5.30
3.50
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0753
10/25/73 BAR:24.64 DB:69 WB:49
REL.HUM:23.4% NOX COR: .825
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.51
4.54
4.25
4.66
76. 7
98.0
69.2
85.5
401.3
427.0
340.3
397.5
1.75
0.97
1.37
1.25
16.52
14.96
19.25
16.29
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3490
2306
4141
2.94
0.92
6.45
104
994
433
294
248
500
190
130
320
175
3. 10
0.90
5.30
3.50
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 262
1973 CHEV STAW 454 4500LBS
8CYL 4BBL AUTOMATIC 017416 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, EVC, PCV
FROM OWNER
FROM INSP.
:==============" MAINTENANCE STATUS ===
I.CO I.RPM TIM DWL PCV A.CL
1.70 -0160 +00 +01 OK OK
1.70 -0160 +00 +01 OK OK
CHOKE A.PMP MISF. NOXC
OK NA YES OK
OK NA YES OK
STATION NO. 2
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC
250
250
2500HC
40
40
I. CO
1.60
1.60
2500CO
0. 15
0. 15
FAILURE
PASS
PASS
COST
5.50
5.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO.-C0754
10/25/73 BAR:24.64 DB:69 WB:48
REL.HUM:20* 4% NOX COR: .812
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
2.98
2.40
2.49
2.55
41.6
37.7
31.5
36.8
771.3
786.3
624.1
738.2
2.99
1.38
3.96
2.43
10.52
10.44
13.07
11.08
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
1613
1550
945
2. 14
0.19
0.32
41
1408
2328
251
264
211
100
85
50
75
1.70
0.20
0.35
0. 19
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0754
10/25/73 BAR
REL.HUM:
:24.64
20.4%
DB: 69
NOX COR
WB:48
: .812
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
2.98
2.40
2.49
2.55
41.6
37.7
31.5
36.8
771.3
786.3
624.1
738.2
2.99
1.38
3.96
2.43
10.52
10.44
13.07
11.08
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
1613
1550
945
2. 14
0.19
0.32
41
1408
2328
251
264
211
100
85
50
75
1.70
0.20
0.35
0. 19
AUTOMOTIVE
TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 263
1968 DODG DART 273 3000LBS
8CYL 2BBL 3 SPEED 065448 MILES
IDLE INSPECTION ONLY
HAS: EMC, NO EVC, PCV
sasaaaassaaassassassss
=»==.==««- MAINTENANCE STATUS
3 3=33:
======
==============
SS3=S
I. CO
I.RPM TIM DUL PCV A
.CL
CHOKE
A.PMP MISF.
NOXC
FROM
OWNER 4.19
+0080 +02 +00 OK
OK
OK
NA NO
NA
FROM
INSP. 4.19
+0080 +02 +00 OK
OK
OK
NA NO
NA
STATION NO. 3
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
160
160
2500HC
100
100
I. CO
2.90
2.90
2500CO
0.35
0. 35
FAILURE
PASS
PASS
COST
0.00
6.00
6.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0755
10/25/73 BAR:24.65 DB:70 WB:47
REL.HUM:15.5% NOX COR: .796
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.96
4.25
3.32
4.14
43.0
61.4
35. 1
50.3
421.1
437.6
367.0
414.6
4.92
2.80
4.41
3.69
17.65
16.26
20.58
17.58
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3073
2351
2420
4.52
0.36
0.63
80
3305
3793
315
347
405
170
175
210
140
3.60
0.30
0.50
1. 10
*************************
AS RECEIVED FROM
INS PECTION *********************
TEST NO:CO755
10/25/73 BAR
REL.HUM:
:24.65
15.5%
DB: 70
NOX COR:
WB: 47
: .796
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.96
4.25
3.32
4.14
43.0
61.4
35.1
50.3
421.1
437.6
367.0
414.6
4.92
2.80
4.41
3.69
17.65
16.26
20.58
17.58
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3073
2351
2420
4.52
0.36
0.63
80
3305
3793
315
347
405
170
175
210
140
3.60
0.30
0.50
1. 10
AUTOMOTIVE
TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 264
1972 OPEL 1900 116 2250LBS
4CYL 2BBL 4 SPEED 022672 MILES
IDLE INSPECTION ONLY
HAS: EMC, EVC, NO PCV
3S=33S==3333
S33338S3
aaasaaa
=»== MAINTENANCE STATUS
as:
I. CO
I.RPM
TIM DWL PCV A,
.CL
FRCH OWNER
1.29
-0200
+05 +04 NA
OK
FRCM INSP.
6.80
+0000
+03 +04 NA
OK
CHOKE A.PMP MISF. NOXC
OK NA YES NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 5
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
385
135
135
2500HC
160
150
150
1. CO
0. 17
2. 70
2.70
2500CO
1.30
1.80
1.80
FAILURE
HC
PASS
PASS
COST
5.50
5.50
11.00 TOT.
ftftft*ft**ftft***ftft*ftftft*********
TEST NO:CO772
AS RECEIVED FROM OWNER ***************************
10/26/73 BAR:24.77 DB:72 WB:50
REL.HUM:20.4% NOX COR: .821
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7. 11
6.05
4.65
5.88
107.2
105.4
63.4
94.2
273.2
282.0
238.7
268.2
2. 15
0.84
1.85
1.40
19.19
19.08
25.22
20.49
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3340
3823
3495
1.42
3.02
1.48
58
1219
3005
386
470
447
90
185
155
190
1.40
2.60
1.40
3.60
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0795
10/29/73 BAR:24.53 DB:77 WB:52
REL.HUM:17.5% NOX COR: .823
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.39
4.24
4.55
4.78
93.0
74.5
68.0
76.5
295.1
290.0
253.0
280.8
2.79
1.32
1.87
1. 78
19.30
21.18
23.80
21.40
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4638
4118
3603
7.30
3.79
1.52
46
714
2838
356
512
412
230
375
275
210
6.30
3.20
1.40
3.00
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. .80011
-------
*** COLORADO-393 ***
VEHICLE 265
1969 CHEV CAPR 327 4000LBS
8CYL 4BBL AUTOMATIC 030213 MILES
COMBINATION RETROFIT
HAS: EMC, NO EVC, PCV
ssaaasasasa
332333=33
aaeasaaa
== MAINTENANCE STATUS
saa:
I. CO
I.RPM
TIM DWL PCV A,
.CL
FROM
OWNER
7.60
-0060
+01 +00 OK
OK
FROM
INSP.
3.50
+0000
+00 +00 OK
OK
CHOKE A.PMP MISF. NOXC
OK NA YES NA
OK NA YES NA
STATION NO. 1
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
340
240
170
170
2500HC
350
200
40
40
I. CO
7.40
5.80
2.80
2.80
2500CO
0.90
0.80
0.40
0.40
FAILURE
BOTH
CO
PASS
PASS
COST
2.50
0.00
5.00
7.50 TOT.
**************AAA*****A***A
TEST NO:CO770
AS RECEIVED FROM OWNER ***************************
10/26/73 BAR:24.76 DB:72 WB:50
REL.HUM:20.4% NOX COR: .821
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
9.73
5.18
4.19
5.86
167.3
78. 1
41.6
86.6
544.8
515.4
463. 1
507.0
4.69
4.28
6.61
5.01
10.62
13.61
16.44
13.46
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
7236
3398
2761
8.11
1.27
0.28
39
2208
4137
629
452
361
420
270
160
380
7.00
1. 10
0.25
1.60
AS RECEIVED FROM
INSPECTION ************************
TEST NO:CO785
10/29/73 BAR
REL.HUM:
:24.61
22.5%
DB: 71
NOX COR
WB:50
: .827
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.41
4.13
4.12
4.81
148.9
54.5
27.2
66.7
551.6
573.3
475.9
541.7
3.76
3.19
4.30
3.62
11.01
13. 25
16.75
13.46
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4020
3013
2101
3.95
1.78
0.32
70
1401
3205
471
425
318
350
240
130
150
3. 10
1.50
0.30
1.70
AUTOMOTIVE
TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 266
1967 FORD MUST 200 3000LBS
6CYL 1BBL 3 SPEED 064477 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
aaaasssaaoBSsaasa&as
=» MAINTENANCE
; STATUS
aaaaaaaaaa:
I. CO
I. RPM
TIM DWL
PCV A
.CL CHOKE
FROM OWNER
3.90
40125
-02 -02
OK
OK OK
FROM INSP.
0.40
-0055
+04 -01
OK
OK OK
IDLE INSPECTION -
STATION NO.
6
I.HC
2500HC
I.CO
2500CO
INITIAL INSPECTION
320
280
5.80
8.70
AFTER I.RPM ADJUST
320
280
5.90
8.70
AFTER I.MX/TM
ADJ1
300
380
1.80
7.80
AFTER I.MX/TM
AD J 2
REPAIRS
FINAL INSPECTION
300
380
1.80
7.80
NA
NA
FAILURE
CO
CO
PASS
PASS
YES
YES
NOXC
NA
NA
COST
4.50
1.50
1.50
7.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0769
10/26/73 BAR:24.76 DB:72 WB:50
REL.HUM:20.4% NOX COR: .821
SCO
HC
CO
CO 2
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.89
5.37
4.52
5.45
94.5
106.1
85.2
97.9
298.6
288.5
264.4
283.9
1.67
0.89
1.42
1.20
18.99
18.86
21.59
19.58
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
3878
3798
4156
4.29
3.86
6.58
70
1091
576
325
435
535
220
270
340
2500 RPM
240
3.80
3.30
5.40
6.00
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:CO786
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
10/29/73 BAR:24.59 DB:70 WB:50
REL.HUM:24.5% NOX COR: .833
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
10.33
9.55
5.78
8.67
143.4
138.0
131. 1
137.2
258.8
272.4
231.5
258.2
0.86
0.62
0.57
0.66
17.23
17.14
19.54
17.77
8039
4375
4088
0.62
7.35
6.29
206
363
642
1726
581
550
1300
400
360
420
0.60
6.00
5.10
7.40
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 267
1967 FORD FALC 200 2750LBS
6CYL 1BBL 3 SPEED 103550 MILES
SEA LEVEL RETROFIT
HAS: NO EMC, NO EVC, PCV
MAINTENANCE STATUS ===========
¦ 3 3335
FROM OWNER
FROM INSP.
I.CO I.RPM
0.70 +0000
4.70 -0100
TIM DWL
+09 -01
+09 +00
PCV
OK
OK
A.CL
BAD
BAD
CHOKE
NA
NA
A.PMP MISF. NOXC
NA NO NA
NA YES NA
— IDLE
INSPECTION
STATION NO. 7
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
430
420
4.20
4. 10
BOTH
2.50
AFTER I.RPM ADJUST
430
420
4.20
4. 20
BOTH
2.50
AFTER I.MX/TM ADJ1
300
280
3.10
3. 10
PASS
2.50
AFTER I.MX/TM ADJ2
REPAIRS
2.50
FINAL INSPECTION
300
280
3.10
3. 10
PASS
10.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0784
10/26/73 BAR:24.80 DB:69 WB:52
REL.HUM:32.9% NOX COR: .864
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
3.85
34.2
375.7
7.33
20. 16
COLD STABILIZED
2.77
29.6
354.3
3. 36
21.75
HOT TRANSIENT
2.40
21.6
308. 1
5.39
25.47
1975 COMPOSITE
2.89
28.3
345.9
4. 76
22.29
IDLE KEYMODE
2233
0.86
84
240
260
0-80
LOW CR. KEYMODE
3124
0. 31
3872
464
340
0. 10
HI. CR. KEYMODE
3074
0. 71
3976
445
300
0.60
2500 RPM
150
0.30
AAA * * AAA A ********* *******
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0796
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
10/30/73 BAR:24.72 DB:69 WB:50
REL.HUM:26.5% NOX COR: .837
HC
CO
CO 2
NOX
MPC
LHC
SHC
SCO
5.31
3.45
3.29
3.79
53.4
46. 1
36.0
44.8
364.4
321.6
280.2
319. 1
5.61
2.98
4.62
3.99
19. 15
21.99
25.65
22. 18
2269
3057
3120
0.57
0.46
2.09
84
3606
2468
261
444
446
125
275
250
500
0.46
0.60
1.70
0.60
AUTOMOTIVE TESTING LABORATORIES.INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 268
1973 DODG DART 225 3000LBS
6CYL 2BBL AUTOMATIC 025094 MILES
IDLE INSPECTION ONLY
HAS: EMC, EVC, PCV
FROM OWNER
FROM INSP.
I.CO I.RPM
4.60 +0000
4.60 +0000
.==== MAINTENANCE STATUS =»==
TIM DWL PCV A.CL
+02 +00 OK BAD
+02 400 OK BAD
CHOKE A.PMP MISF. NOXC
OK NA YES OK
OK NA YES OK
IDLE INSPECTION
STATION NO. 3
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
200
200
2500HC
120
120
I. CO
6.00
6.00
2500CO
1.80
1.80
FAILURE
PASS
PASS
COST
0.00
12.00
12.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:CO774 10/26/73 BAR:24. 77 DB: 72 WB:50
REL.HUM:20.4% NOX COR: .821
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.78
3.74
3.17
3.80
86.4
51.9
52. 7
59.4
426.6
409. 3
346.8
395.6
3.43
3. 16
3.26
3.24
15.42
17.71
20. 26
17.78
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
4223
3070
4214
4.95
1.06
7.98
86
2968
529
352
368
488
250
235
295
2500 RPM
135
4.40
1.00
6.80
0.85
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:CO774
10/26/73 BAR:24.77 DB:72 WB:50
REL.HUM:20.4% NOX COR: .821
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.78
3.74
3.17
3.80
86.4
51.9
52.7
59.4
426.6
409.3
346.8
395.6
3.43
3.16
3.26
3.24
15.42
17.71
20.26
17.78
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4223
3070
4214
4.95
1.06
7.98
86
2968
529
352
368
488
250
2 35
295
135
4.40
1.00
6.80
0.85
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 269
1968 TOYO CORO 116 2500LBS
4CYL 2BBL 4 SPEED 061312 MILES
IDLE INSPECTION ONLY
HAS: EMC, NO EVC, NO PCV
FROM OWNER
FROM INSP.
MAINTENANCE STATUS ===
I.CO I.RPM TIM DWL PCV A.CL
1.50 -0210 +00 +00 NA BAD
1.50 -0210 +00 +00 NA BAD
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
— IDLE INSPECTION
STATION NO. 5
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.-MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
100
100
2500HC
50
50
I.CO 2500CO
1.10 0.90
1.10 0.90
FAILURE COST
PASS 5.50
PASS
5.50 TOT.
***************************
TEST NO:C0773
AS RECEIVED FROM OWNER ***************************
10/26/73 BAR:24.77 DB:72 WB:50
REL.HUM:20.4% NOX COR: .821
HC
CO
CO 2
NOX
MPG
COLD
COLD
HOT
1975
TRANSIENT
STABILIZED
TRANSIENT
COMPOSITE
3.82
3.06
2.88
3.17
64.6
64. 1
73.0
66.7
348.7
367.7
274.8
338.0
2.22
1.00
1.17
1.30
19.26
18.63
22.34
19.67
LHC
SHC
SCO
IDLE KEYMODE
2825
3. 10
34
412
90
1.20
LOW CR. KEYMODE
1780
2.30
550
317
60
1.20
HI. CR. KEYMODE
2515
3.44
1821
372
90
2. 20
2500 RPM
30
0.57
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0773
10/26/73 BAR:24.77 DB:72 WB:50
REL.HUM:20.4% NOX COR: .821
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
3.82
3.06
2.88
3.17
64.6
64. 1
73.0
66.7
348.7
367.7
274.8
338.0
2.22
1.00
1.17
1.30
19.26
18.63
22.34
19.67
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2825
1780
2515
3. 10
2.30
3.44
34
550
1821
412
317
372
90
60
90
30
1.20
1. 20
2. 20
0.57
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 270
1971 CHEV NOVA 250 3500LBS
6CYL 1BBL AUTOMATIC 095217 MILES
IDLE INSPECTION ONLY
HAS: EMC, NO EVC, PCV
FRCM OWNER
FROM INSP.
I. CO I.RPM
2.26 +0140
2.26 +0140
==== MAINTENANCE STATUS =>=¦=
TIM DWL PCV A.CL
-02 +00 BAD OK
-02 +00 BAD OK
CHOKE A.PMP MISF. NOXC
OK NA YES MA
OK NA YES NA
IDLE INSPECTION
STATION NO. 2
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
120
120
2500HC
30
30
I. CO
1.50
2500CO
0. 20
1.50 0.20
FAILURE
PASS
PASS
COST
5.50
5.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0775
10/26/73 BAR:24.77 DB:72 WB:50
REL.HUM:20.4% NOX COR: .821
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.05
2.60
3. 13
3.26
85.1
30.4
32.2
42.3
501. 1
486.2
392.0
463.2
4.07
2.79
4.59
3.56
13.68
16.43
19.68
16.49
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2461
2602
3005
2.47
0.20
1.66
88
2888
2496
255
344
363
140
180
180
65
2. 40
0. 20
1.50
0.29
A A A ********** **** ********
AS RECEIVED FROM
INS PECTION ************************
TEST NO:C0775
10/26/73 BAR
REL.HUM:
:24.77
20.4%
DB: 72
NOX COR
WB: 50
: .821
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.05
2.60
3.13
3.26
85. 1
30.4
32.2
42.3
501.1
486.2
392.0
463.2
4.07
2.79
4.59
3.56
13.68
16.43
19.68
16.49
IDLE KEYMODE
LOW CR. KEYMODE
2461
2602
2.47
0.20
88
2888
255
344
140
180
2.40
0.20
HI. CR. KEYMODE 3005 1.66
2500 RPM
2496
363
180
65
1.50
0. 29
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 271
1967 PONT FIRE 326 3500LBS
8CYL 4BBL AUTOMATIC 059028 MILES
SEA LEVEL RETROFIT
HAS: NO EMC, NO EVC, PCV
FROM CWNER
FROM INSP.
I. CO
6.23
6.23
I.RPM
-0115
-0115
MAINTENANCE STATUS ==
TIM DWL
+00 +00
+00 +00
PCV
OK
OK
A.CL
OK
OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
STATION NO. 9
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC
720
2500HC
400
720 400
I. CO
3.90
2500CO
2.00
3.90 2.00
FAILURE
PASS
PASS
COST
0.00
4.00
4.00 TOT.
***************************
TEST NO:CO787
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
AS RECEIVED FROM OWNER ***************************
10/29/73 BAR:24.59 DB:70 WB:50
REL.HUM:24.5% NOX COR: .833
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
12. 18
9.58
10.32
10. 33
175.2
157.4
143.2
157.2
445.9
405. 1
329.7
392.7
2. 20
1.34
1.69
1.62
11.72
13.04
15. 16
13.25
7305
4055
4353
6.91
2. 17
5.88
49
1713
855
910
566
578
800
370
370
480
5. 10
1.80
4.60
2.80
IDLE KEYMODE
LOW _CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0787
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
10/29/73 BAR:24.59 DB:70 WB:50
REL.HUM:24.5% NOX COR: .833
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
12.18
9.58
10. 32
10.33
175.2
157.4
143.2
157.2
445.9
405.1
329.7
392.7
2.20
1.34
1.69
1.62
11.72
13.04
15.16
13.25
7305
4055
4353
6.91
2. 17
5.88
49
1713
855
910
566
578
800
370
370
480
5. 10
1.80
4.60
2.80
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 272
1966 PLYM FURY 318 4000LBS
8CYL 2BBL AUTOMATIC 092494 MILES
SEA LEVEL RETROFIT
HAS: NO EMC, NO EVC, PCV
FROM OWNER
FROM INSP.
I. CO I. RPM
7.60 +0100
6.80 +0000
" MAINTENANCE STATUS =>=>=>
TIM DWL PCV A.CL
-05 +00 OK BAD
+01 +00 bad bad
CHOKE A.PMP MISF. NOXC
OK NA YES NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 3
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
400
900
600
600
2500HC
300
350
300
300
I. CO
9.20
3.00
4.50
4.50
2500CO
6.50
3.00
2.50
2.50
FAILURE
CO
HC
PASS
PASS
COST
0.00
0.00
0.00
12.00
12.00 TOT.
ft*********;***************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0788
10/29/73 BAR:24.57 DB:70 WB:50
REL.HUM:24.5% NOX COR: .833
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
12.93
7.64
6.81
8.52
208.3
139.2
139.9
153.8
418.1
443.0
393.8
424. 1
2.77
2.87
2.93
2.87
11.33
12.99
14.02
12.86
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
6679
4193
4513
8.03
3.65
3.52
60
2152
2235
785
536
606
710
330
380
165
6.50
3.00
2.90
5. 70
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0797
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
10/30/73 BAR:24.70 DB:71 WB:55
REL.HUM:37.9% NOX COR: .901
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
11.28
8.63
7.05
8.75
172.6
136.7
128.6
142.0
487.9
439.5
406. 1
440.4
3.93
2.91
3.53
3. 30
11.20
13.06
14. 12
12.89
7182
4111
3475
7.48
4.45
3. 10
58
1402
2052
835
524
403
730
360
235
550
6.00
3.50
2.60
4.60
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 273
1970 CHEV CAPR 400 4000LBS
8CYL 2BBL AUTOMATIC 047305 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
FRCtl OWNER
FROM INSP.
================= MAINTENANCE STATUS ===
I. CO I.RPM TIM DUL PCV A.CL
7.00 -0090 -04 +00 OK BAD
3.30 -0080 +06 +00 OK OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 8
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
220
200
140
140
2500HC
140
160
70
70
I. CO
5.00
4.60
3.40
3.40
2500CO
4.00
3.50
1.40
1.40
FAILURE
CO
CO
PASS
PASS
COST
3.50
2.00
2.50
8.00 TOT.
* ******
TEST NO:C0789
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
AS RECEIVED FROM OWNER ***************************
10/29/73 BAR:24.57 DB:78 WB:51
REL.HUM:13.6% NOX COR: .805
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
10.33
5.27
5.11
6.28
208. 1
109. 1
92.9
125.3
600.5
603.4
448.6
559.8
2. 12
2.02
2.09
2.06
9.27
11.25
14.58
11.47
5203
2814
3375
7.60
1.63
3.54
63
1198
1385
475
370
404
250
160
190
110
5.60
1.20
2.90
2.90
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0806
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
10/30/73 BAR:24.56 DB:70 UB:50
REL.HUM:24.5% NOX COR: .833
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
11.44
4.17
5.92
6.18
213.4
79.0
78.7
107.1
64 7.4
648.0
500.8
607.0
2. 35
2.40
2. 72
2.48
8.74
11.34
13.84
11.21
3472
2646
3130
3.66
1.31
2.90
123
1224
1571
411
332
377
260
160
175
80
3.20
1. 00
2.40
2. 10
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 274
1970 BUIC SKYL 350 4000LBS
8CYL 4BBL AUTOMATIC 034266 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
====3====3=====aaaoB3aaaaaa== MAINTENANCE STATUS === =========================»= =
I. CO I.RPM TIM DWL PCV A.CL
FROM OWNER 0.51 -0100 +03 -05 OK OK
FROM INSP. 0.51 -0100 +03 -05 OK OK
CHOKE A.PMP MISF. NOXC
OK OK NO NA
OK OK NO NA
IDLE INSPECTION
STATION NO. 10
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
120
120
2500HC
90
90
I. CO
0.10
2500CO
1.30
0.10 1.30
FAILURE COST
PASS 1.50
PASS
1.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0790 10/29/73 BAR:24.57 DB:78 WB:51
REL.HUM:13.6% NOX COR: .805
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
11.64
231.7
491.6
2.32
9.98
COLD STABILIZED
3.90
58.9
528.2
3.41
14.07
HOT TRANSIENT
3.95
75.3
416.9
3. 18
16. 26
1975 COMPOSITE
5.53
99.6
489.7
3.12
13.42
IDLE KEYMODE
2700
0.54
76
345
200
0.45
LOW CR. KEYMODE
2993
1.08
2587
389
215
1. 10
HI. CR. KEYMODE
4026
8.73
314
493
280
6.80
2500 RPM
160
2.50
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST N0.-C0790
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
10/29/73 BAR:24.57 DB:78 WB:51
REL.HUM:13.6% NOX COR: .805
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
11.64
3.90
3.95
5.53
231.7
58.9
75.3
99.6
491.6
528.2
416.9
489.7
2.32
3.41
3. 18
3. 12
9.98
14.07
16.26
13.42
2700
2993
4026
0.54
1.08
8.73
76
2587
314
345
389
493
200
215
280
160
0.45
1. 10
6.80
2.50
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 276
1966 PONT LEMA 326 3500LBS
8CYL 4BBL AUTOMATIC 073426 MILES
SEA LEVEL RETROFIT
HAS: NO EMC, NO EVC, PCV
===== MAINTENANCE STATUS
FROM CWNER
FROM INSP.
I. CO
7.40
2.00
I.RPM
-0070
-0060
TIM DWL
-03 +00
-01 +00
PCV
OK
OK
A.CL
OK
OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
STATION NO. 4
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
800
620
620
2500HC
225
210
210
I. CO
8.50
4.20
4.20
2500C0
2.60
1. 30
1.30
FAILURE
BOTH
PASS
PASS
COST
0.00
0.00
6.00
6.00 TOT.
* ****************** ft *** ****
TEST NO:CO798
AS RECEIVED FROM OWNER ***************************
10/30/73 BAR:24.70 DB:75 WB:53
REL.HUM:23.3% NOX COR: .846
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
11.94
8.93
6.47
8.88
148.2
126. 3
105. 2
125. 1
493.7
455-. 7
409.4
450.8
3.72
2.65
3.24
3.04
11.65
13.05
14.96
13. 19
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
8090
3838
5241
7.93
0.62
10.14
34
2668
228
881
481
637
800
360
430
2500 RPM
150
6.40
0.52
7.80
2.40
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0810
10/31/73 BAR:24.52 DB:70 WB:49
REL.HUM:21.5% NOX COR: .820
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.55
5.43
4.82
5.70
102. 1
67.2
74.2
76.5
536.8
468.2
419. 1
468.9
5.03
2.79
3.50
3.46
12.35
15.07
16. 17
14.67
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
5575
3476
4772
2.17
0.27
8. 70
51
2495
295
787
500
654
580
280
400
225
1.70
0.30
7.00
0.90
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 277
1966 FORD STAW 289 3000LBS
8CYL 2BBL AUTOMATIC 084032 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
FROM OWNER
FROM INSP.
I.CO I.RPM
7.40 +0060
2.00 +0000
» MAINTENANCE STATUS «=
TIM DWL PCV A.CL
-02 +00 OK BAD
-02 +00 OK OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 1
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
400
520
350
350
2500HC
700
540
500
500
I. CO
8.60
7.20
0.50
0.50
2500CO
8.60
6.00
5.80
5.80
FAILURE
CO
CO
PASS
PASS
COST
2.50
2.00
5.00
4.20
13.70 TOT.
************ A AAA** A A A A A AAA A
TEST NO:C0854
AS RECEIVED FROM OWNER ***************************
11/05/73 BAR:24.55 DB:69 WB:50
REL.HUM:26.7% NOX COR: .838
HC
CO
C02
NOX
MPG
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
14.33
15.94
9.96
13.94
151.0
220.6
128.2
180.4
368.8
344.4
313.6
341.0
1.84
0.89
1.82
1.35
13.67
12.01
16.29
13.32
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
5223
5219
4592
7.75
4.39
3. 72
56
1150
1353
LHC
SHC
SCO
449
235
4.50
706
400
2.50
555
290
2.20
560
5.30
2500 RPM
AAAAAA*AAAAAAAAAAAAAA*AAA AS RECEIVED FROM INSPECTION AAAAAAAAAAA AAAAAAAAAAAAA
TEST NO:C0884
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
11/06/73 BAR:24.64 DB:76 WB:54
REL.HUM:24.3% NOX COR: .856
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
13.27
11.98
9.63
11.60
151.5
164.6
112.9
147.5
401.0
367. 7
347.9
369.2
1.95
1. 14
2.06
1.57
13.08
13.41
16.02
13.97
3928
5405
4972
2.15
3.79
5.86
64
1149
591
544
764
640
135
185
135
250
2.00
3.50
5. 20
9.80
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 278
1965 FORD MUST 289 3000LBS
8CYL 4BBL AUTOMATIC 059885 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
assaaaaaaaaaasassssaasdssaaaas MAXNT£ NANC E STATUS sssssaaaaaaaaaassaasasasssasaa
I.CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 5.30 +0120 +00 +00 OK BAD OK NA NO NA
FROM INSP. 5.30 +0120 +00 +00 OK BAD OK NA NO NA
STATION NO.
1
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
230
2500HC
270
230 270
I. CO 2500C0
3.10 2.60
3.10 2.60
FAILURE COST
PASS 2.50
PASS
2.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0801
10/30/73 BAR:24.70 DB:72 WB:50
REL.HUM:20.5% NOX COR: .821
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
9.05
5.73
4.93
6.20
96.5
100.6
55.5
87.2
429.2
418.5
396.1
414.5
3. 16
2.32
3.96
2.95
14.61
14.97
17.85
15.59
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
4394
4167
3539
5.64
3.35
2.30
64
1321
1304
485
653
651
320
470
310
4. 20
2.70
1.90
2500 RPM
380
3.40
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0801
10/30/73 BAR:24.70 DB:72 WB:50
REL.HUM:20.5% NOX COR: .821
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
9.05
5.73
4.93
6.20
96.5
100.6
55.5
87.2
429.2
418.5
396.1
414.5
3.16
2.32
3.96
2.95
14.61
14.97
17.85
15.59
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4394
4167
3539
5.64
3.35
2.30
64
1321
1304
485
653
651
320
470
310
380
4.20
2.70
1.90
3.40
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 279
1973 TOYO STAW 120 2500LBS
4CYL 2BBL AUTOMATIC 003829 MILES
IDLE INSPECTION ONLY
HAS: EMC, EVC, PCV
aasa:
sasasasaa
333333
S3SSSS33
==*= MAINTENANCE STATUS
38:
I. CO
I.RPM
TIM DWL PCV A,
.CL
FROM
OWNER
3.01
+0030
+00 +00 OK
OK
FROM
INSP.
3.01
+0030
+00 +00 OK
OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 5
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
290
2500HC
110
290 110
I. CO
2.60
2500CO
2. 20
2.60 2.20
FAILURE COST
PASS 5.50
PASS
5.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0802
10/30/73 BAR:24.70 DB:72 WB:50
REL.HUM:20.5% NOX COR: .821
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.36
3.24
2.76
3.34
78.6
61.6
41.9
59.7
429.0
374.9
359.2
381.9
3.73
2. 14
3.51
2.85
15.73
18.48
20.53
18.32
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4856
3174
3009
4.70
2.60
1.75
82
828
2135
563
418
393
250
190
165
140
2.60
1.90
1.40
3.00
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0802
10/30/73 BAR:24.70 DB:72 WB:50
REL.HUM:20.5% NOX COR: .821
HC
CO
C02
NOX
MPC
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.36
3.24
2.76
3.34
78.6
61.6
41.9
59.7
429.0
374.9
359.2
381.9
3.73
2. 14
3.51
2.85
15.73
18.48
20.53
18.32
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4856
3174
3009
4.70
2.60
1.75
82
828
2135
563
418
393
250
190
165
140
2.60
1.90
1.40
3.00
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 280
1967 CHEV STAW 327 4000LBS
8CYL 4BBL 3 SPEED 096491 MILES
SEA LEVEL RETROFIT
HAS: NO EMC, NO EVC, PCV
FROM OWNER
FROM INSP.
==========,=====,== MAINTENANCE STATUS ==»==
I. CO I.RPM TIM DWL PCV A.CL
5.90 -0240 -02 +06 OK BAD
3.60 -0150 -02 +05 OK BAD
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 2
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
540
520
360
360
2500HC
340
350
320
320
I. CO
5.60
5.40
2.60
2.60
2500CO
6.80
6. 60
5.20
5.20
FAILURE
BOTH
BOTH
PASS
PASS
COST
5.50
3.30
3.30
12.10 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0799
10/30/73 BAR:24.70 DB:75 WB:53
REL.HUM:23.3% NOX COR: .846
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
19.84
12.63
8.96
13. 12
210. 1
184.6
143.5
178.5
361.5
351.7
316.6
344.0
1.32
0.78
1.21
1.01
11.80
13.06
15.61
13.37
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
7510
5583
4698
6.80
6. 12
4.05
55
720
1375
879
686
597
860
550
400
4.80
4.70
3.30
2500 RPM
*************************
TEST NO:C0811
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
640
5.80
AS RECEIVED FROM INSPECTION ************************
10/31/73 BAR:24.52 DB: 70 WB:49
REL.HUM:21.5% NOX COR: .820
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
16.58
8.16
7.63
9.78
202.0
152.7
136. 1
158.4
393.4
398. 1
329.5
378. 1
1. 12
0.61
0.96
0.82
11.67
13.41
15.69
13.54
5088
4709
3963
3.84
5.94
3.83
57
428
1020
585
669
564
400
430
320
440
3. 10
4.60
3. 10
5.10
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 281
1966 FORD MUST 200 3000LBS
6CYL IBBlT™ AUTOMATIC 059352 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
FROM OWNER
FROM INSP.
>===============»=» MAINTENANCE STATUS =¦=¦=
l.CO I.RPM TIM DWL PCV A.CL
2.60 -0050 -06 -01 BAD OK
2.60 -0050 -06 -01 BAD OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 6
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
260
260
2500HC
250
250
I. CO
3.40
3.40
2500C0
6.00
6.00
FAILURE
PASS
PASS
COST
4.50
4.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0800
10/30/73 BAR:24.70 DB:72 WB:52
REL.HUM:26.3% NOX COR: .848
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
12. 14
4.89
4.20
6.22
221.4
68. 1
80.9
103.7
383.2
420.0
375.0
399.8
1. 12
2.51
2.58
2.24
11.57
16.42
17.28
15.29
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4146
4143
4520
2.80
2.77
8.85
97
1589
526
452
500
523
310
335
310
330
2.70
2.40
7. 10
5.00
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0800
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2 500 RPM
10/30/73 BAR:24.70 DB:72 WB:52
REL.HUM:26.3% NOX COR: .848
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
12. 14
4.89
4.20
6.22
221.4
68. 1
80.9
103.7
383.2
420.0
375.0
399.8
1. 12
2.51
2.58
2.24
11.57
16.42
17.28
15.29
4146
4143
4520
2.80
2.77
8.85
97
1589
526
452
500
523
310
335
310
330
2. 70
2.40
7.10
5.00
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 282
1968 FORD FALC 170 3000LBS
6CYL 1BBL 3 SPEED 097889 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
FROM OWNER
FROM INSP.
1.CO I.RPM
2.AO +0020
2.40 +0020
»» MAINTENANCE STATUS «=
TIM DWL PCV A.CL
-04 +01 OK BAD
-04 +01 OK BAD
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 9
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
180
180
2500HC
200
200
I. CO
1.40
1.40
2500CO
2.80
2.80
FAILURE
PASS
PASS
COST
0.00
4.00
4.00 TOT.
*************************** as RECEIVED FROM OWNER ***************************
TEST NO:C0813
10/31/73 BAR:24.53 DB:68 WB:48
REL.HUM:22.5% NOX COR: .818
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
19.60
5.43
3.84
7.96
197.9
89.9
52.6
102.2
263.6
379.4
311.8
336.4
0.28
0.82
1.75
0.97
13.99
16.56
21.90
17.06
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3021
3936
2894
3.04
1.72
1.22
37
1830
2169
325
515
379
130
210
140
60
2.30
1. 20
1.00
0.40
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST N0:C0813
10/31/73 3AR
REL.HUM:
:24.53
22.5%
DB: 68
NOX COR
WB: 48
: .818
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
19.60
5.43
3.84
7.96
197.9
89.9
52.6
102. 2
263.6
379.4
311.8
336.4
0.28
0.82
1. 75
0.97
13.99
16.56
21.90
17.06
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3021
3936
2894
3.04
1.72
1.22
37
1830
2169
325
515
379
130
210
140
60
2.30
1.20
1.00
0.40
AUTOMOTIVE
TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 283
1968 PONT CATA 400 4500LBS
8CYL 4BBL AUTOMATIC 075255 MILES
COMBINATION RETROFIT
HAS: EMC, NO EVC, PCV
aaaa:
3S33SS3
aaaaaaaaa
aaaaaaaa
=»=> MAINTENANCE STATUS
saaa:
saaaaaa
aaaaaaa
aaaaaaa
=3333
I. CO
I.RPM
TIM DWL PCV A
.CL
CHOKE
A.PMP
MISF.
NOXC
FROM
OWNER
0.13
-0190
+01 +01 OK
OK
OK
NA
YES
NA
FROM
INSP.
0.13
-0190
+01 +01 OK
OK
OK
NA
YES
NA
STATION NO. 1
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
270
2500HC
160
270 160
I. CO
3.40
2500CO
3.40
3.40 3.40
FAILURE COST
PASS 2.50
PASS
2.50 TOT.
******ft***********ft********
TEST NO:C0812
AS RECEIVED FROM OWNER ***************************
10/31/73 BAR:24.53 DB :71 WB:49
REL.HUM:19.6% NOX COR: .815
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.32
6.03
4.92
5.78
161.9
178.8
105.0
154.8
620.2
546.5
480.6
543.6
2.70
1.07
2.59
1.83
9.96
10.52
13.47
11.06
IDLE KEYMODE
LOU CR. KEYMODE
HI. CR. KEYMODE
2634
3255
3185
0. 16
3.37
4. 12
64
796
1295
371
455
454
180
240
220
0. 13
0.80
3.40
2500 RPM
225
2.80
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0812
10/31/73 BAR:24.53 DB : 71 WB:49
REL.HUM:19.6% NOX COR: .815
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.32
6.03
4.92
5.78
161.9
178.8
105.0
154.8
620. 2
546.5
480.6
543.6
2.70
1.07
2.59
1.83
9.96
10.52
13.47
11.06
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2634
3255
3185
0.16
3.37
4.12
64
796
1295
371
455
454
180
240
220
225
0. 13
0.80
3.40
2.80
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 284
1971 AMMO AMBA 401 4000LBS
8CYL 4BBL AUTOMATIC 031837 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
*= MAINTENANCE STATUS ====
FROM OWNER
FROM INSP.
I. CO
7.60
6.60
I.RPM
-0090
-0060
TIM DWL
+00 +07
+00 +00
PCV
OK
OK
A.CL
OK
OK
CHOKE A.PMP MISF. NOXC
OK NA YES NA
OK NA YES NA
STATION NO. 10
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
41.70 TOT.
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
160
1200
3.60
0.60
HC
1.50
150
1240
2.40
0.80
HC
1.50
130
1020
1.60
0.80
HC
1.50
160
700
1.40
0.60
HC
3.00
34.20
170
290
3.00
0.60
PASS
AA**AA********
TEST NO:C0814
AS RECEIVED FROM OWNER " ***************************
10/31/73 BAR:24.53 DB:70 WB:45
REL.HUM:10.0% NOX COR: .775
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
8.77
6.74
7.36
7.34
74.9
120.7
74.8
98.4
'559.6
491.0
449. 2
493.8
6.12
2.83
5.31
4.21
12.63
12.69
15.09
13.26
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
5701
3584
3224
8. 25
1.34
1.54
49
2427
3779
459
496
417
270
300
2 30
1510
6.30
1. 10
1.20
1.00
******A*A AAAAAAA*********
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0862
11/05/73 BAR:24.73
REL.HUM:33.8%
DB: 70
NOX COR:
WB: 53
: .874
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
11.80
8.00
7.09
8.55
115.9
110.8
112.0
112.2
539. 2
508.0
447.9
497.9
6.65
4.70
4.81
5.14
11. 74
12.59
13. 78
12.70
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
5609
3859
4250
7.53
1.44
6.33
61
2971
1025
603
471
498
345
265
275
6.50
1. 10
6. 10
2500 RPM
600
1.40
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 285
1968 PLYM BARR 318 3500LBS
8CYL 2BBL AUTOMATIC 060568 MILES
HIGH ALTITUDE RETROFIT
HAS: QIC, NO EVC, PCV
FROM OWNER
FROM INSP.
================= MAINTENANCE STATUS ===========
I.CO I.RPM TIM DWL PCV A.CL CHOKE
2.80 +0120 +00 -02 OK BAD OK
6.20 +0000 +00 -02 OK BAD OK
sssasasassssssaassa
A.PMP MISF. NOXC
NA YES NA
NA NO NA
IDLE INSPECTION
STATION NO. 6
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
350
340
240
240
2500HC
250
240
150
150
I. CO
2.80
2.80
3.20
3.20
2500CO
1.50
1.50
1.50
1.50
FAILURE
HC
HC
PASS
PASS
COST
4.50
1.50
3.00
9.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0815
10/31/73 BAR:24.53 DB:74 WB:50
REL.HUM:17.1% NOX COR: .812
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.94
4.31
4.00
4.78
115.6
49.7
56.0
65.2
467.2
480.6
431. 7
464.2
4.30
5.46
5.93
5.35
13.28
15.56
16. 73
15.31
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4076
3060
3018
3.00
0.60
1.95
73
3951
2666
368
395
366
2 70
260
225
330
2.70
0.50
1.50
1.20
AAA**********A***********
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0833
11/01/73 BAR:24.25
REL.HUM:12.2%
DB :81
NOX COR:
WB: 52
: .805
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.24
4.48
3.91
4.90
134.4
63.3
70.7
80.2
491.9
504.8
470.4
492.6
3.04
3. 11
3.76
3. 27
12.26
14.40
15.00
14.05
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
4051
3389
3115
6.69
2.57
3.27
73
1643
1249
443
429
374
310
275
210
5.80
2.20
2.80
170
2.70
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 286
1968 DODG CHAR 318 3500LBS
8CYL 2BBL AUTOMATIC 065609 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
FROM OWNER
FROM INSP.
,==.===«======«=. MAINTENANCE STATUS ===
I. CO I.RPM TLM DWL PCV A.CL
A. 40 +0000 +00 -02 OK BAD
4.30 -0050 +06 -02 OK BAD
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 3
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
300
200
200
200
2500HC
520
190
170
170
I. CO
4.40
2.50
2.50
2.50
2500CO
3.00
3.80
3.00
3.00
FAILURE
BOTH
HC
PASS
PASS
COST
0.00
0.00
0.00
12.00
12.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST N0::C0816
10/31/73 BAR:24.49 DB:74 WB:50
REL.HUM:17.2% NOX COR: .813
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
HC
8.95
6.31
5.72
6.70
CO
170.2
99.4
96.6
113.5
C02
410.3
458.8
411.1
435.4
NOX
1.24
2.29
1.82
1.94
MPG
12.61
14.03
15.33
14.03
LHC
SHC
SCO
IDLE KEYMODE
4096
5. 10
81
439
270
3. 10
LOW CR. KEYMODE
4482
2. 14
1617
601
420
1.90
HI. CR. KEYMODE
4187
4.52
648
475
280
3.80
2500 RPM
250
3. 20
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0834
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
11/01/73 BAR:24.20 DB:77 WB:52
REL.HUM:17.8% NOX COR: .826
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
13.05
5.85
5.28
7.20
201.2
81.4
89.2
108.6
434.8
465.0
405.8
442.2
1.23
2.37
1.95
2.02
11.24
14.57
15.83
14.01
3886
4415
3876
4.79
2.82
4.74
89
1268
570
489
599
446
340
420
270
340
4. 10
2.60
4.30
3. 10
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 287
1971 BUIC LESA 455 4500LBS
8CYL 4BBL AUTOMATIC 017998 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
FROM OWNER
FROM INSP.
I.CO I.RPM
5.10 +0020
3.60 +0020
== MAINTENANCE STATUS =¦==
TLM DUL PCV A.CL
-10 +00 OK BAD
-06 +00 OK BAD
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 7
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
420
430
4.10
4.20
BOTH
2.50
AFTER I.RPM ADJUST
420
430
4.10
4.20
BOTH
0.00
AFTER I.MX/TM ADJ1
220
200
2.10
2.00
PASS
2.50
AFTER I.MX/TM ADJ2
0
0
0.00
0.00
NO ANS.
2.50
REPAIRS
FINAL INSPECTION
220
200
2.10
2.00
PASS
k k k k k k k k kk k k * k k k k k k * * * k k * it k
TEST NO:C0817
7.50 TOT.
AS RECEIVED FROM OWNER ***************************
10/31/73 BAR:24.47 DB: 74 WB:50
REL.HUM:17.2% NOX COR: .813
SCO
HC
CO
CO 2
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.58
6.05
5.09
5.89
143.0
151.2
102. 2
135.9
775.5
763.9
665.8
739.1
3.61
1.56
3.42
2.50
8.72
8.73
10.57
9. 17
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
3900
2971
2904
5.56
0.92
2.53
71
1454
1798
406
331
328
275
180
155
2500 RPM
70
4.50
0.75
2.20
2.25
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0835
11/01/73 BAR:24.20 DB:78 WB:51
REL.HUM:13.9% NOX COR: .808
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.50
4.92
4.95
5.26
133. 2
103.6
99.1
108.5
730.3
753. 1
635.7
715.8
3.35
1.91
3.24
2.58
9.27
9.56
11.04
9.87
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3340
3509
2790
3.72
3.92
1.64
77
663
2169
357
411
308
240
270
140
80
3.60
3.70
1.50
2.30
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 288
1968 PONT TEMP 350 3500LBS
8CYL 2BBL AUTOMATIC 040178 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
assa:
S38S33S
========
=========
==> MAINTENANCE STATUS
sa;
I. CO
I.RPM
TIM DWL PCV A.
.CL
FROM
OWNER
5.40
-0130
+03 +00 OK
OK
FROM
INSP.
2.50
-0025
-02 +00 OK
OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 8
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
250
250
130
130
2500HC
110
110
100
100
I. CO
5.00
5.00
1.40
1.40
2500CO
1.00
1.00
1.40
1.40
FAILURE
CO
CO
PASS
PASS
COST
3.50
2.00
0.00
2.00
7.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO.:C0818
10/31/73 BAR:24.47 DB:69 WB:49
REL.HUM:23.6% NOX COR: .826
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT' TRANSIENT
1975 COMPOSITE
7.68
4.47
4.33
5. 10
162.6
66.3
74.9
88.8
587.9
611. 1
521.5
581.4
2.92
2.83
3.75
3. 10
10.26
12.21
13.64
12.08
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
4165
3341
3352
6.40
1.33
2.71
70
1590
1586
520
419
412
360
250
225
2500 RPM
145
4.90
1. 10
2.30
1.00
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0836
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2 500 RPM
11/01/73 BAR:24.20 DB:75 WB:51
REL.HUM:18.5% NOX COR: .823
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
10.65
4.19
3.84
5.44
177.3
67.2
66.9
90.2
604.7
615.7
521.0
587.1
3.11
2.52
3.72
2.97
9.71
12. 12
13.95
11.94
3127
3088
3080
2.92
1.36
2.39
161
1652
1827
348
355
360
220
210
190
120
2.35
1.40
2. 15
1.90
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 289
1969 VOLK SEDA 91 2000LBS
4CYL 1BBL 4 SPEED 063512 MILES
TUNE UP EVALUATION
HAS: EMC, NO EVC, NO PCV
saaaa
3333==
SS33SS33S
sassssasa
« MAINTENANCE STATUS
as:
I. CO
I.RPM
TIM DWL PCV A
.CL
FROM
OWNER
6.20
+0100
+00 +00 OK
OK
FROM
INSP.
6.20
+0100
+00 +00 OK
OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 5
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER "I.MX/TM ADJ 1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
160
160
2500HC
160
160
I. CO
3.30
3.40
2500CO
3.60
3.60
FAILURE
PASS
PASS
COST
5.50
5.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0826 11/01/73 BAR:24.23 DB:70 WB:50
REL.HUM:24.9% NOX COR: .836
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.46
6.09
4.35
5.68
98.5
84.3
71.4
83. 7
258.7
259.1
213.8
246.4
1.73
1.38
1.69
1.54
20.52
21.67
26.21
22.50
IDLE KEYMODE
LOW CR. KEYMODE
III. CR. KEYMODE
4124
3156
2844
6.44
3.90
2.28
68
840
2428
312
374
377
210
220
215
2500 RPM
300
4.90
3.10
1.90
3.40
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0826
11/01/73 BAR:24.23 DB:70 WB:50
REL.HUM:24.9% NOX COR: .836
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.46
6.09
4.35
5.68
98.5
84.3
71.4
83. 7
258.7
259. 1
213.8
246.4
1.73
1.38
1.69
1.54
20.52
21.67
26.21
22.50
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4124
3156
2844
6.44
3.90
2.28
68
840
2428
312
374
377
210
220
215
300
4.90
3. 10
1.90
3.40
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 291
1969 PLYM FURY 318 4000LBS
8CYL 2BBL AUTOMATIC 052667 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
=========,========*=====,=======,= MAINTENANCE STATUS ======
I.CO I.RPM TIM DWL PCV A.CL
FROM OWNER 7.80 -0140 +08 +00 OK BAD
FROM INSP. 1.37 -0200 +00 +00 OK OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
•STATION NO.
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
620
460
8. 10
5. 10
BOTH
2.50
AFTER I.RPM ADJUST
600
420
7.10
5.00
BOTH
2.50
AFTER I.MX/TM ADJ1
380
360
3. 10
3. 10
PASS
2.50
AFTER I.MX/TM ADJ2
REPAIRS
6.70
FINAL INSPECTION
380
360
3. 10
3. 10
PASS
14.20 TOT.
***************************
AS RECEIVED
FROM OWNER ***************************
TEST NO:C0839
11/02/73 BAR:24.57 DB:75 WB:52
REL.HUM:20.8% NOX COR: .833
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
7.53
141.9
4 55.7
2.28
12.68
COLD STABILIZED
5.98
118.0
459.0
2.05
13.42
HOT TRANSIENT
5.42
94.4
421.8
2. 72
15. 16
1975 COMPOSITE
6. 15
116.5
448.0
2.29
13.69
IDLE KEYMODE
3590
1.44
97
443
580
7.00
LOW CR. KEYMODE
3475
2.15
1281
378
250
1.70
HI. CR. KEYMODE
3360
3.04
1786
381
230
2. 50
2500 RPM
230
3.00
AS RECEIVED FROM
INSPECTION ************
TEST NO:C0868
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
11/05/73 BAR:24.66 DB:72 WB:53
REL.HUM:29.3% NOX COR: .863
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
7.09
5.10
4.24
5.27
129.7
81.0
64.0
86.5
418.9
464.3
419.2
442.3
2.86
2.91
4. 19
3.25
13.80
14.65
16.70
14.97
3590
3534
3344
1.44
2.45
2.84
97
1899
1911
443
462
406
2 70
240
185
165
1. 25
2.30
2.45
2.60
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 292
1971 CHEV NOVA 307 3500LBS HIGH ALTITUDE RETROFIT
8CYL 2BBL AUTOMATIC 029533 MILES HAS: EMC, NO EVC, PCV
=a====aa====r=3====s=sao33===a MAINTENANCE STATUS ==============================
I.CO I.RPM
FROM UJNER 4.40 -0030
FROM INSP. 4.40 -0030
STATION NO. 2
I.HC
INITIAL INSPECTION 290
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION 290
************* **************
TEST NO:C0840
HC
COLD TRANSIENT 7.50
COLD STABILIZED 5.40
HOT TRANSIENT 4.77
1975 COMPOSITE 5.67
IDLE KEYMODE 5191
LOW CR. KEYMODE 4124
HI. CR. KEYMODE 3531
2500 RPM
*************************
TEST NO:C0840
HC
COLD TRANSIENT 7.50
COLD STABILIZED 5.40
HOT TRANSIENT 4.77
1975 COMPOSITE 5.67
IDLE KEYMODE 5191
LOW CR. KEYMODE 4124
HI. CR. KEYMODE 3531
2500 RPM
TIM DWL PCV A.CL
+01 +01 OK OK
+01 +01 OK OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
- IDLE INSPECTION
2500HC I.CO 2500CO FAILURE COST
60 2.60 0.80 PASS 5.50
60 2.60 0.80 PASS
5.50 TOT.
AS RECEIVED FROM OWNER ***************************
11/02/73 BAR:24.60 DB:71 WB:51
REL.HUM:25.5% NOX COR: .841
CO
C02
NOX
MPG
LHC .
SHC
SCO
79.7
46.7
43.3
52. 7
536.4
530.4
422. 1
501.6
4. 13
3.26
3.79
3.59
12.99
14.34
17.63
14. 79
5.09
0.79
1.32
55
1996
2272
534
544
399
350
350
215
150
3.80
0.55
1. 20
1.70
AS RECEIVED FROM INSPECTION ************************
11/02/73 BAR:24.60 DB : 71 WB:51
REL.HUM:25.5% NOX COR: .841
CO
C02
NOX
MPG
LHC
SHC
SCO
79.7
46.7
43.3
52. 7
536.4
530.4
422.1
501.6
4.13
3.26
3.79
3.59
12.99
14. 34
17.63
14. 79
5.09
0.79
1.32
55
1996
2272
534
544
399
350
350
215
150
3.80
0.55
1. 20
1.70
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 293
1972 FORD MUST 351 3500LBS
8CYL 4BBL AUTOMATIC 019843 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, EVC, PCV
====»==========================¦ MAINTENANCE STATUS =======»===========>=========*===
FROM OWNER
FROM INSP.
I. CO I.RPM
5.10 +0140
5.10 +0140
TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
+00 +04 OK BAD OK NA NO NA
+00 +04 OK BAD OK NA NO NA
STATION NO. 10
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC
150
2500HC
150
150 150
I. CO
3.00
2500CO
0.80
3.00 0.80
FAILURE COST
PASS 1.50
PASS
1.50 TOT.
***************************
TEST NO:C0841
AS RECEIVED FROM OWNER ***************************
11/02/73 BAR:24.61 DB:73 WB:52
REL.HUM:24.4% NOX COR: .844
HC
CO
CO 2
NOX
MPC
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
8.28
5.79
5.81
6.32
174.3
135. 1
114.9
137.7
691.2
654.3
568.2
638. 1
1.31
1.05
1.31
1.17
8.98
10.06
11.61
10. 19
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4817
2137
2665
6.28
1.72
1.69
54
386
849
469
228
251
260
90
100
100
4.60
1.40
1.50
1.60
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0841
11/02/73 BAR
REL.HUM:
:24.61
24.4%
DB: 73
NOX COR:
WB:52
.844
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
8.28.
5.79
5.81
6.32
174.3
135. 1
114.9
137.7
691.2
654.3
568.2
638. 1
1.31
1.05
1.31
1.17
8.98
10.06
11.61
10. 19
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4817
2137
2665
6.28
1.72
1.69
54
386
849
469
228
251
260
90
100
100
4.60
1.40
1.50
1.60
AUTOMOTIVE
TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 294
1969 CHRY NEWP 383 4500LBS
8CYL 2BBL AUTOMATIC 065163 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
assasaaaaas
saasssssa
=======>«===* MAINTENANCE STATUS
=====
ssssaas
3333=33
3333333
33333
I. CO
I.RPM TIM DWL PCV A
• CL
CHOKE
A.PMP
MISF.
NOXC
FROM OWNER
0.14
+0000 -K)0 +01 OK
OK
OK
NA
YES
NA
FROM INSP.
0.14
+0000 +00+01 OK
OK
OK
NA
YES
NA
STATION NO.
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
100
2500HC
110
100 110
I. CO
0.20
2500CO
2.50
0.20 2.50
FAILURE COST
PASS 4.00
PASS
4.00 TOT.
******** **** A AAA** *********
TEST NO:C0837
AS RECEIVED FROM OWNER ***************************
11/02/73 BAR:24.53 DB:69 WB:50
REL.HUM:26.7X NOX COR: .839
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.65
3.32
4.76
4.63
124.9
37.8
101.9
73.8
614.3
672.7
519.0
617.8
2.47
2.42
2.44
2.43
10.67
11.99
12.83
11.90
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
917
2772
3655
0.15
1. 22
4.17
85
1252
1156
174
332
409
40
160
215
0. 15
1. 10
3.30
2500 RPM
420
1.00
************************* as RECEIVED FROM INSPECTION ************************
TEST NO:C0837
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
11/02/73 BAR:24.53 DB:69 WB:50
REL.HUM:26.7% NOX COR: .839
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
7.65
3.32
4.76
4.63
124.9
37.8
101.9
73.8
614. 3
672.7
519.0
617.8
2.47
2.42
2.44
2.43
10.67
11.99
12.83
11.90
917
2772
3655
0.15
1.22
4.17
85
1252
1156
174
332
409
40
160
215
420
0.15
1. 10
3.30
1.00
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 295
1970 DODG POLA 383 4500LBS
8CYL 2BBL AUTOMATIC 053254 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
============================== MAINTENANCE STATUS ================
I.CO I.RPM TIM DWL PCV A.CL
FROM OWNER 3.80 +0140 +05 +00 OK BAD
FRCM INSP. 3.50 +0030 +05 +00 OK OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 8
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
140
140
140
2500HC
80
40
40
I. CO 250OCO
4.20 0.20
4.00 0.20
4.00
0.20
FAILURE
CO
PASS
PASS
COST
3.50
2.00
5.50 TOT.
*************** St* ft**** AAA* A
TEST NO:CO842
AS RECEIVED FROM OWNER ***************************
11/02/73 BAR:24.64 DB:69 WB:49
REL.HUM:23.4% NOX COR: .825
HC
CO
C02
NOX
MPC
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.60
4.45
3.91
4.96
114.6
74.3
71.6
82.0
618.4
622.7
524.6
594.6
4.52
4.61
4.85
4.66
10.83
11.82
13.71
12.05
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3108
2548
2816
4.00
0. 15
1.22
70
3200
2700
260
311
314
145
155
150
50
3.20
0. 17
1.20
0. 30
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0861
11/05/73 BAR
REL.HUM:
:24.75
27.21
DB : 73
NOX COR
WB: 53
: .857
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.50
4.34
3.99
4.91
106.4
68.0
69.5
76.5
572. 1
607.0
542.7
581.8
4.05
4.18
5.12
4.41
11.67
12. 24
13.40
12.41
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3359
3064
3063
4.07
0.24
1.69
88
3244
2269
331
351
334
155
135
115
50
3. 10
0.20
1.40
0.65
AUTOMOTIVE
TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 296
1965 FORD MUST 260 3000LBS
8CYL 2BBL AUTOMATIC 052813 MILES
IDLE INSPECTION ONLY
HAS: NO EMC, NO EVC, PCV
======== MAINTENANCE STATUS ===
FROM OWNER
FROM INSP.
I. CO
10.30
2.60
I.RPM
-0015
-0055
TIM DWL
+08 +00
+0 7 +00
PCV
OK
OK
A.CL
BAD
OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 4
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
****
640
640
2500HC
220
150
150
I. CO
9.20
1.00
1.00
2500CO
0.60
0.50
0.50
FAILURE
BOTH
PASS
PASS
COST
5.00
2.00
7.00 TOT.
*******:&********** ***** ****
TEST NO:C0825
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
AS RECEIVED FROM OWNER ***************************
11/01/73 BAR:24.23 DB:70 WB:49
REL.HUM:21.8% NOX COR: .823
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
10.80
15.81
10. 15
13. 19
138.5
135.5
101. 2
126.6
454.6
370.0
378.0
389.9
3.61
2.06
3.55
2.80
12.60
14.07
15.64
14. 13
15667
4243
3775
11.09
3.01
3.05
15
1894
2372
A 4fkje
623
555
****
420
340
760
8.30
2.50
2.60
1.40
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0853
11/02/73 BAR:24.73 DB:69 WB:51
REL.HUM:29.7% NOX COR: .850
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.97
6.95
5. 15
6.66
121.7
79. 1
58.5
82.3
429.8
403.5
378.4
402.0
3.26
2.82
3.96
3.23
13.78
16. 20
18. 30
16. 13
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4890
3925
3763
2.84
2.15
2.89
88
1859
2458
685
540
493
530
370
310
340
2.40
1.90
2.60
4.50
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 297
1971 PLYM DUST 198 3000LBS
6CYL 1BBL 3 SPEED 027784 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
MAINTENANCE STATUS
I. CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 5.90 -0080 +00 +03 OK BAD OK NA NO NA
FROM INSP. 0.40 -0160 +00 +03 OK BAD OK NA YES NA
STATION NO. 3
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
1.11C
350
150
150
2500HC
125
125
125
I.CO 2500CO
9.00 3.00
2.80 3.00
2.80
3.00
FAILURE
BOTH
PASS
PASS
COST
0.00
0.00
6.00
6.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0838
11/02/73 BAR:24.56 DB:71 WB:50
REL.HUM:22.5% NOX COR: .828
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
HC
8.80
7.03
6.31
7.20
CO
135.5
119.0
106.2
118.9
C02
336.8
350.4
308.4
335.9
NOX
1.60
1.30
1.80
1.50
MPG
15.42
15.91
17.98
16. 33
LHC
SHC
SCO
IDLE KEYMODE
5055
6.24
2590
416
270
4.80
LOW CR. KEYMODE
4013
4.64
819
483
330
3.60
HI. CR. KEYMODE
3375
3.89
1441
394
220
3. 10
2500 RPM
210
4.80
************************* as RECEIVED FROM INSPECTION ************************
TEST NO:C0877
11/06/73 BAR:24.65 DB:70 WB:51
REL.HUM:27.5% NOX COR: .846
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.53
5.11
5.25
5.66
113.9
85. 2
86.5
91.6
313.2
345.4
306.7
327.9
1.70
1.10
1.71
1.40
17.26
17.98
19.39
18. 19
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2204
6431
6748
0.44
4.37
7.70
71
810
286
238
665
758
140
150
200
130
0. 15
1.50
2.00
1.20
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 298
1972 AMMO JAVE 360 3500LBS
8CYL 4BBL 4 SPEED 023737 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, EVC, PCV
MAINTENANCE STATUS =
33S333=3333333333333333333333
I.CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 1.20 -0180 -02 +00 BAD BAD OK NA NO NA
FROM INSP. 1.20 -0180 -02 +00 BAD BAD OK NA NO NA
IDLE INSPECTION
STATION NO. 4
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
70
70
2500HC
32
32
I. CO
0.55
0.55
2500C0
0.28
0.28
FAILURE
PASS
PASS
COST
5.00
5.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0870
11/06/73 BAR:24.65 DB:69 WB:50
REL.HUM:26.6% NOX COR: .837
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
20.55
223.4
525.7
0.90
9.46
COLD STABILIZED
6.00
101.4
566.0
1.35
11.96
HOT TRANSIENT
9.09
121. 1
487.6
1.45
12.60
1975 COMPOSITE
9.90
132.4
535.8
1.28
11.49
IDLE KEYMODE
926
1.70
55
182
30
0.50
LOW CR. KEYMODE
569
1.05
846
192
25
0.32
HI. CR. KEYMODE
954
2.34
788
222
35
0.65
2500 RPM
45
0.09
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0870
11/06/73 BAR:24.65 DB:69 WB:50
REL.HUM:26.6% NOX COR: .837
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
20.55
6.00
9.09
9.90
223.4
101.4
121.1
132.4
525.7
566.0
487.6
535.8
0-90
1.35
1.45
1.28
9.46
11.96
12.60
11.49
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
926
569
954
1.70
1.05
2.34
55
846
788
182
192
222
30
25
35
45
0.50
0.32
0.65
0.09
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 299
1972 PLYM SATE 318 3500LBS
8CYL 2BBL AUTOMATIC 028091 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, EVC, PCV
============
sa=ss3s =
========
=== MAINTENANCE STATUS
= = :
I. CO
I.RPM
TIM DWL PCV A
.CL
FROM OWNER
8.19
-0200
+00 +00 OK
OK
FROM INSP.
9.20
+0050
+00 +00 OK
OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
— IDLE INSPECTION
STATION NO. 9
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
350
300
300
2500HC
150
150
150
I. CO
6. 10
3.80
3.80
2500CO
0.90
1.90
1.90
FAILURE
BOTH
PASS
PASS
COST
0.00
0.00
4.00
A.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0873
11/06/73 BAR:24.65 DB:69 WB:49
REL.HUM:23.4% NOX COR: .824
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.48
6.43
5.40
6. 16
132.9
153.4
118.3
139.4
450.6
437.8
363.6
419.9
1.61
1.11
1.23
1.25
13. 10
12.74
15. 72
13.53
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
7153
3656
3476
9.00
3. 22
3.91
44
703
768
664
447
406
160
110
90
90
2. 70
1.00
1.20
1.30
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0898
11/07/73 BAR:24.69 DB:80 WB:56
REL.HUM:22.5% NOX COR: .863
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.50
5.41
5.05
5.33
100.9
127.3
122.7
120.5
500.3
489.7
387.4
463.5
2.03
1.21
1.24
1.39
13. 17
12.60
14.94
13.30
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
7441
4009
3749
10.54
3.87
4.65
35
596
625
776
512
434
600
380
270
200
9.00
3.90
4.00
4.20
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 300
1973 OPEL MANT 116 2250LBS
4CYL 2BBL 4 SPEED 006817 MILES
IDLE INSPECTION ONLY
HAS: EMC, EVC, NO PCV
MAINTENANCE STATUS =*
FROtl OWNER
FROM INSP.
I. CO
6.07
3.70
I. RPM
-0150
+0000
TIM DWL
-01 -08
-01 -05
PCV A.CL
NA OK
NA OK
CHOKE A.PMP MISF. NOXC
OK NA NO OK
OK NA NO OK
IDLE INSPECTION
STATION NO. 5
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
290
240
180
180
2500HC
150
160
130
130
I. CO
6.30
5.00
2.60
2.60
2500CO
2.30
2.30
1.00
1.00
FAILURE
CO
CO
PASS
PASS
COST
5.50
5.50
5.50
16.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0872
HC CO
COLD TRANSIENT 5.28 76.9
COLD STABILIZED 5.05 88.9
HOT TRANSIENT 4.00 59.7
1975 COMPOSITE 4.81 78.3
IDLE KEYMODE 6566 8.58
LOW CR. KEYMODE 3058 1.73
HI. CR. KEYMODE 3253 2.39
2500 RPM
11/06/73 BAR:24.65 DB:70 UB:52
REL.HUM:30.7% NOX COR: .860
C02
NOX
MPG
LHC
SHC
SCO
274.6
288.7
244.3
273.4
2.31
1.36
2.12
1.77
21.60
20.04
25.38
21.64
43
1641
2040
567
364
424
150
100
120
2.90
2.50
1.20
80
0.90
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0901
11/07/73 BAR:24.69 DB:74 WB:53
REL.HUM:25.2% NOX COR: .852
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.24
3.59
3.10
3.59
67.6
62.9
48. 1
59.8
307.8
319.4
268.9
303.0
2.24
1.41
2. 11
1.78
20.84
20.73
25.13
21.82
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3069
3306
3506
3.75
2.66
3.69
70
1000
1956
257
331
402
155
205
245
220
3.50
2.45
3.60
3. 10
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 301
1973 MERC COME 302 3000LBS
8CYL 2BBL AUTOMATIC 010804 MILES
HIGH ALTITUDE RETROFIT
HAS: QIC, EVC, PCV
FROM OWNER
FROM INSP.
I.CO I.RPM
3.40 +0040
2.90 -0010
»== MAINTENANCE STATUS ==============================
TIM DHL PCV A.CL CHOKE A.PMP MISF. NOXC
+02 +00 OK BAD OK NA NO OK
-03 +00 - OK OK OK NA NO OK
STATION NO.
IDLE INSPECTION
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
440
420
4. 10
4.20
BOTH
2.50
AFTER I.RPM ADJUST
440
420
4.20
4.20
BOTH
2.50
AFTER I.MX/TM ADJ1
220
200
2.20
2. 10
PASS
2.50
AFTER I.MX/TM ADJ2
REPAIRS
2.50
FINAL INSPECTION
220
200
2.20
2. 10
PASS
10.00 TOT.
***************************
AS RECEIVED
FROM OWNER ***************************
TEST NO:C0874
11/06/73 BAR:24.65 DB:78 WB:54
REL.HUM:20.8% -NOX COR: .844
HC
CO
C02
NOX
MPG
LHC
SI1C
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.98
5.31
4.08
5.11
107.3
114.9
68.2
100.3
562.8
503.0
483. 1
510.0
1.54
1. 11
1.40
1.28
11.87
12.72
14.76
13.03
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3306
3379
3296
4.66
2.50
1.78
75
558
868
290
386
390
65
80
80
70
1.00
0.70
0.50
0.80
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0899
11/07/73 BAR:24.69 DB:74 WB:53
REL.HUM:25.2% NOX COR: .852
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.90
4.28
3.91
4.52
91.0
67.9
60.0
70.5
578.9
596.7
498.7
565.8
1.55
1. 19
1.35
1.31
12.03
12.42
14.71
12.89
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3402
3472
3378
3.11
2.06
1.40
115
687
1003
406
391
388
330
260
235
110
3. 10
1.80
1.40
2.30
AUTOMOTIVE TESTINC LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 302
1973 BUIC CENT 350 4000LBS
8CYL 4BBL AUTOMATIC 006508 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, EVC, PCV
MAINTENANCE STATUS
ssaasosassssssss
ssssxssassss
I.CO I.RPM TIM DWL PCV A.CL
FROM OWNER 0.63 +0000 -02 +00 OK OK
FROM INSP. 0.63 +0000 -02 +00 OK OK
CHOKE A.PMP MISF. NOXC
OK NA NO OK
OK NA NO OK
IDLE INSPECTION —
STATION NO. 2
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
50
50
2500HC
30
30
I.CO 2500CO
I.00 0.60
1.00 0.60
FAILURE COST
PASS 5.50
PASS
5.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO-.C0871
11/06/73 BAR:24.65 DB:69 WB:50
REL.HUM:26.6% NOX COR: .837
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
3.83
129.6
656.3
1.58
10.21
COLD STABILIZED
2.44
73. 1
668.8
0.90
11.25
HOT TRANSIENT
2.85
88.4
531.2
2.06
13.11
1975 COMPOSITE
2.84
89.2
628.0
1.36
11.46
IDLE KEYMODE
534
0.80
72
172
35
0.62
LOW CR. KEYMODE
2278
3.61
445
366
145
0.80
HI. CR. KEYMODE
1801
3.10
1091
320
100
0.80
2500 RPM
35
0.20
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0871
11/06/73 BAR:24.65 DB:69 WB:50
REL.HUM:26.6% NOX COR: .837
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
3.83
2.44
2.85
2.84
129.6
73. 1
88.4
89.2
656.3
668.8
531.2
628.0
1.58
0.90
2.06
1.36
10.21
11.25
13.11
11.46
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
534
2278
1801
0.80
3.61
3.10
72
445
1091
172
366
320
35
145
100
35
0.62
0.80
0.80
0.20
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 303
1973 PLYM DUST 318 3500LBS
8CYL 2BBL AUTOMATIC 006473 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, EVC, PCV
======================«======== MAINTENANCE STATUS ==============================
I.CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 2.45 -0120 +00 +00 OK OK OK NA NO OK
FROM INSP. 2.45 -0120 +00 +00 OK OK OK NA NO OK
IDLE INSPECTION
STATION NO.
INITIAL INSPECTION
RPM ADJUST
MX/TM ADJ1
MX/TM ADJ 2
AFTER I
AFTER I
AFTER I
REPAIRS
FINAL INSPECTION
I. HC
80
80
2500HC
90
90
I. CO
0.30
0.30
2500CO
1.50
1.50
FAILURE
PASS
PASS
COST
4.50
4.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0875
11/06/73 BAR:24.65 DB:82 WB:56
REL.HUM:19.5% NOX COR: .853
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.26
3.66
3.74
4.43
134.8
77.5
86.9
92. 1
500.8
505.2
455.4
490.5
1.64
1.35
1.66
1.50
12.11
13.95
14.75
13.72
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2377
3220
3186
2.45
2.36
3.66
76
1455
781
242
424
394
45
85
80
80
0.60
0. 70
1.00
0.90
&&&&&&&&&**&&&&&*&*&£&*&& as RECEIVED FROM INSPECTION ************************
TEST NO:C0875
11/06/73 BAR:24.65 DB:82 WB:56
REL.HUM:19.5% NOX COR: .853
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.26
3.66
3.74
4.43
134.8
77.5
86.9
92. 1
500.8
505.2
455.4
490.5
1.64
1.35
1.66
1.50
12.11
13.95
14.75
13.72
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2377
3220
3186
2.45
2.36
3.66
76
1455
781
242
424
394
45
85
80
80
0.60
0. 70
1.00
0.90
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 304
1972 DODG CORO 318 3500LBS
8CYL 2BBL .AUTOMATIC 022983 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, EVC, PCV
=3==sa3aa=ss3=s3SM33aa==aa==» MAINTENANCE STATUS ==========»====================
I. CO I.RPM TIM DWL PCV A.CL CHOICE A.PMP MISF. NOXC
FROM OWNER 2.75 -0150 +00 -01 BAD BAD OK NA NO NA
FROM INSP. 2.75 -0150 +00 -01 BAD BAD OK NA NO NA
IDLE INSPECTION
STATION NO. 3
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I. HC
150
150
2500HC
175
175
I. CO
0.70
0.70
2500CO
1.80
1.80
FAILURE COST
PASS 0.00
PASS
6.00
6.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0885
11/07/73 BAR:24.67 DB:69 WB:51
REL.HUM:29.7% NOX COR: .851
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.34
4.38
4.43
4.60
97.0
79.2
95.3
87.4
469.4
473.9
399.9
452.4
3.29
2.42
2.49
2.62
13.94
14.54
15.80
14.74
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
3380
3612
3829
2.91
2.50
5.21
53
1422
917
313
478
484
225
350
350
2500 RPM
210
2.70
2.50
4.80
3.40
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0885
11/07/73 BAR:24.67 DB:69 WB:51
REL.HUM:29.7% NOX COR: .851
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.34
4.38
4.43
4.60
97.0
79.2
95.3
87.4
469.4
473.9
399.9
452.4
3.29
2.42
2.49
2.62
13.94
14.54
15.80
14.74
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3380
3612
3829
2.91
2.50
5.21
53
1422
917
313
478
484
225
350
350
210
2.70
2.50
4.80
3.40
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 305
L969 AMMO AMBA 290 4000LBS
8CYL 2BBL AUTOMATIC 054001 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
=================== ============ MAINTENANCE STATUS ===
I.CO I.RPM TIM DWL PCV A.CL
FROM 017NER 4.95 -0130 +00 +01 OK OK
FROM INSP. 4.95 -0130 +00 +01 OK OK
CHOKE A.PMP MISF. NOXC
OK NA YES NA
OK NA YES NA
IDLE INSPECTION
STATION NO. 1
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
90
90
2500HC
70
70
I. CO 2500CO
0.50 1.80
0.50 1.80
FAILURE COST
PASS 2.50
PASS
2.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0886
11/07/73 BAR:24.67 DB:76 UB:51
REL.HUM:16.4% NOX COR: .814"
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.03
4.66
5.41
5.16
133.3
91.3
118.5
107.6
527.6
544.5
475.3
521.8
2.14
2. 18
2.28
2.20
11.78
12.67
13.12
12.60
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4060
3441
4170
5.50
2.02
5.65
68
1171
671
412
424
527
300
255
330
180
4.90
2.20
5.00
3.00
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0886
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
11/07/73 BAR:24.67 DB:76 WB:51
REL.HUM:16.4% NOX COR: .814
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
6.03
4.66
5.41
5.16
133.3
91.3
118.5
107.6
527.6
544.5
475.3
521.8
2. 14
2. 18
2.28
2.20
11.78
12.67
13.12
12.60
4060
3441
4170
5.50
2.02
5.65
68
1171
671
412
424
527
300
255
330
180
4.90
2.20
5.00
3.00
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 306
1969 BUIC ELEC 430 4500LBS
8CYL 4BBL AUTOMATIC 034898 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
FROM OWNER
FROM INSP.
¦===»=*============ MAINTENANCE STATUS ===
I.CO I.RPM TIM UWL PCV A.CL
1.20 -0160 -05 +03 OK OK
2.35 -0010 -05 +03 OK OK
CHOKE A. PttP MISF. NOXC
OK NA NO NA
OK NA NO NA
STATION NO. 6
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC
220
200
200
2500HC
150
120
120
I.CO 2500CO
5.00 2.60
3.20 2.20
3.20
2.20
FAILURE
CO
PASS
PASS
COST
4.50
1.50
6.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0888
11/07/73 BAR:24.66 DB:74 WB:50
REL.HUM:17.0% NOX COR: .811
SCO
HC
CO
C02
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.36
6.42
5.67
6.41
191.3
135.7
130.5
145.9
617.1
628.6
507.4
592.6
2.92
2.09
3.09
2.54
9.46
10.33
12.19
10.58
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
3414
3413
3170
1.20
2.09
3.26
70
1268
1633
282
383
383
210
270
240
2500 RPM
185
1.20
1.90
3.00
2.80
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0915
11/08/73 BAR:24.71 DB:75 WB:54
REL.HUM:26.1% NOX COR: .861
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
9.73
6.24
5.57
6.79
243.0
134.6
128.5
155.6
628.1
635.9
534.7
606.2
2.90
1.72
3.26
2.40
8.56
10.27
11.81
10.21
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3904
3390
3086
2.43
1.93
1.43
150
1472
2546
443
395
368
355
225
225
250
2.40
1.85
1.40
3.20
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 307
1969 CHEV NOVA 230 3000LBS
6CYL 1BBL AUTOMATIC 029124 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
3S3S3SSSS3SS
aasssss
=========== MAINTENANCE STATUS
I. CO
I.RPM TIM DWL PCV A
.CL
CHOKE
A.PMP
MISF
FROM OWNER
3.50
-0100 -01 -01 OK
OK
OK
NA
YES
FROM INSP.
3.60
-0050 +03 +00 OK
OK
OK
NA
YES
NOXC
NA
NA
STATION NO.
IDLE INSPECTION
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
320
700
3.60
2.50
BOTH
5.50
AFTER I.RPM ADJUST
390
720
2.50
2.20
NO ANS.
3.30
AFTER I.MX/TM ADJ1
280
400
4.40
0.80
BOTH
3.30
AFTER I.MX/TM ADJ2
270
260
3.80
2.50
PASS
3.30
REPAIRS
FINAL INSPECTION
270
260
3.80
2.50
PASS
15.40 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0887
11/07/73 BAR:24.66 DB:74 WB:50
REL.HUM:17.0% NOX COR: .811
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.23
4.00
3.98
4.67
124.8
59.0
68.6
75.5
420.6
429.0
394.2
417.6
3. 17
3. 19
3.86
3.37
13.92
16.66
17.30
16. 17
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3993
3692
3230
4. 20
3.70
2.80
63
1147
1833
374
446
378
280
335
245
1700
3.70
3.50
2.60
2.40
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0916
11/08/73 BAR
REL.HUM:
: 24.70
30.2%
DB: 73
NOX COR
WB:54
: .872
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.78
3.44
3.45
4.35
138.8
59.0
72.3
79.4
437.9
437.4
381.2
421.9
2.44
2. 19
2.57
2.35
13.08
16.46
17.61
15.89
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
3435
3471
3362
3.86
3.37
4.36
92
975
897
408
391
362
330
280
220
3.50
3.35
4. 15
2500 RPM
350
2.10
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 308
1969 FORI) TORI 351 3500LBS
8CYL 2BBL AUTOMATIC 021037 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
SS33S
IS33S3SS
saassssa
sasssssaa
« MAINTENANCE STATUS
»:
I.CO
I.RPM
TIM DWL PCV A
.CL
FROM
OWNER
3.60
-0030
+00 +02 OK
OK
FROM
INSP.
3.60
-0030
+00 +02 OK
OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
STATION NO. 10
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I. MX/Til AD J 2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC
120
120
2500HC
30
30
I. CO
0.70
2500C0
0.50
0.70 0.50
FAILURE COST
PASS 1.50
PASS
1.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0889
11/07/73 BAR:24.68 DB:70 WB:50
REL.HUM:24.4% NOX COR: .832
SCO
HC
CO
C02;
NOX
MPG
LHC
SHC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.74
3.56
4.21
3.99
51.8
38.2
46.2
43.3
594.5
572.8
479.7
551.5
3.26
2.27
2.55
2.56
12.89
13.83
15.74
14.09
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
3389
2741
3360
3.81
0.35
1.68
78
1384
1918
318
319
407
200
175
235
2500 RPM
110
3.40
0.30
1.50
2.50
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0889
11/07/73 BAR:24.68 DB:70 WB:50
REL.HUM:24.4% NOX COR: .832
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.74
3.56
4.21
3.99
51.8
38. 2
46.2
43.3
594.5
572.8
479.7
551.5
3.26
2.27
2.55
2.56
12.89
13.83
15.74
14.09
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3389
2741
3360
3.81
0.35
1.68
78
1384
1918
318
319
407
200
175
235
110
3.40
0.30
1.50
2.50
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 309
1969 FORD TORI 351 3500LBS
8CYL 2BBL AUTOMATIC 074369 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
============================== MAINTENANCE STATUS ==============================
FROM OWNER
FROM INSP.
I.CO I.RPM
6.50 -0050
4.80 +0000
TIM DHL PCV A.CL CHOKE A.PMP MISF. NOXC
-02 -02 OK OK OK NA YES NA
-02 -02 OK OK OK NA NO NA
IDLE INSPECTION
STATION NO. 8
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I. HC
520
160
160
2500HC
200
80
80
I.CO 2500CO
7.80 0.30
2.80 0.30
2.80
0.30
FAILURE
BOTH
PASS
PASS
COST
3.50
2.00
5.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:CO890
11/07/73 BAR:24.68 DB:75 WB:52
REL.HUM:20.7% NOX COR: .832
HC
CO
C02
NOX
MPG
LHC
' SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.47
5.49
5.18
5.82
126.3
104.6
92.5
105.8
457.2
466.1
412.9
449.5
2.28
2.33
2.90
2.48
13. 11
13.75
15.50
14.05
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
6065
3695
3776
8.05
1.59
2.72
53
2237
2211
554
453
453
380
300
280
140
7.00
1.30
2.30
1.80
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0917
11/08/73 BAR
REL.HUM:
:24.72
27.5%
DB : 70
NOX COR:
WB: 51
: .845
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.12
4.49
5.52
5.33
103.9
62.2
49.9
67.5
525. 1
545.5
471.9
520.8
3.85
4.45
4.93
4.46
12.53
13.55
15.68
13.84
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
3985
3519
3679
5.10
0.54
1. 16
172
2643
3354
223
373
437
410
280
285
4.90
0.60
1. 15
2500 RPM
70
0.50
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 310
1972 FORD MAVE 302 3000LBS
8CYL 2BBL AUTOMATIC 008455 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, EVC, PCV
== MAINTENANCE STATUS
FROM OWNER
I. CO
2.35
I.RPM
-0020
TIM
-02
DWL
+00
PCV
OK
A.CL
OK
CHOKE
OK
A.PMP MISF.
NA
NO
NOXC
NA
FROM INSP. 1.50
+0000
-02 +00
OK
OK
OK
NA
NO
NA
t r\i IT TM^PFfTTON -
STATION NO. 7
I.HC
2500HC
I.CO
2500CO
FAILURE
COST
INITIAL INSPECTION
480
480
4.30
4.10
BOTH
2.50
AFTER I.RPM ADJ'UST
480
460
4.30
4. 10
BOTH
2.50
AFTER I.MX/TM ADJ 1
330
320
2.20
2.10
PASS
2.50
AFTER I.MX/TM ADJ2
REPAIRS
2.50
FINAL INSPECTION
330
320
2.20
o
»¦ <
CM
PASS
10.00
TOT.
•kifkifk &£&&&&&* "kieick * A A A A&&&A it
AS RECEIVED
FROM OWNER ***************************
TEST NO:C0902
11/08/73
BAR:24. 68
DB : 69 WB:49
REL.
HUM:
: 23.4%
NOX COR:
.824
HC
CO CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT 6.01 68.4
COLD STABILIZED 4.41 43.5
HOT TRANSIENT 7.52 51.1
1975 COMPOSITE 5.61 50.9
IDLE KEYMODE 2795 2.52
LOW CR. KEYMODE 3858 1.77
HI. CR. KEYMODE 4029 1.53
2500 RPM
488.1
543.8
476.0
513.4
3.30
2.45
3.75
2.99
92
1511
2761
14.49
14.22
15.35
14.58
267
479
505
210
365
3 70
195
3.90
1.80
1.50
1.80
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0934
11/09/73 BAR:24.83 DB:72 UB:51
REL.HUM:23.2% NOX COR: .833
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.43
3.88
5.01
4.72
86.2
41.7
41.1
50.8
534.3
554.7
459.9
524.1
3.58
1.84
3.60
2.69
12.91
14.08
16.48
14.39
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2734
3507
3737
1.60
1.59
1.68
132
1190
2500
325
445
490
225
300
325
125
1.40
1.50
1.60
1.30
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 311
1972 FORD MAVE 250 2750LBS
6CYL 1BBL AUTOMATIC 022036 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, EVC, PCV
==============================1 MAINTENANCE STATUS ==============================
I.CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 8.10 -0120 -04 +00 OK BAD OK NA NO NA
FROM IN'SP. 2.45 -0050 -06 +00 OK BAD OK NA NO NA
IDLE INSPECTION
STATION NO. 4
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ 1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I. HC
155
150
95
95
2500HC
125
100
130
130
I. CO
5.50
2.50
0.90
0.90
2500C0
2.00
3. 10
3.00
3.00
FAILURE
CO
CO
PASS
PASS
COST
5.00
1.00
1.00
7.00 TOT.
*************************** A.S RECEIVED FROM OWNER ***************************
TEST NO:C0903
11/08/73 BAR:24.67 DB:80 WB:56
REL.HUM:22.6% NOX COR: .864
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.51
3.68
3.34
3.76
75.0
102.9
76.5
89.7
480.4
396.8
384.0
410.8
4.15
1.80
3. 36
2.72
14.54
15.62
17.30
15.80
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4617
3330
2764
9.10
3.67
1.91
58
1156
2295
390
411
312
250
290
180
210
8.40
3.40
1.80
4.20
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0920
11/09/73 BAR
REL.HUM:
:24.82
24.2%
DB:73
NOX COR:
WB: 52
: .842
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.21
3.23
4.14
3.69
74.2
62.2
84.4
70.9
411.9
437.9
356.7
409.9
2.81
2.23
2.52
2.43
16.44
16.32
17.72
16.71
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2356
3535
3053
2.67
3.98
2.52
114
900
2130
201
487
391
100
335
230
2.50
3.50
2.20
2500 RPM
200
4.00
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 312
1972 MERC COME 302 3000LBS
8CYL 2BBL AUTOMATIC 008589 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, EVC, PCV
FROM OWNER
FROM INSP.
I.CO I.RPM
2.30 +0020
2.30 +0020
¦= MAINTENANCE STATUS =>=»=
TIM DWL PCV A.CL
-01 - -08 OK OK
-01 -08 OK OK
:3a3S333333aasa3333S33S3SS
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 9
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ 1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
100
100
2500HC
110
110
I. CO
0.40
0.40
2500CO
1.30
1.30
FAILURE COST
PASS 0.00
PASS
4.00
4.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0904
11/08/73 BAR:24.67 DB:80 WB:56
REL.HUM:22.6% NOX COR: .864
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.15
3.14
4.34
3.89
87.9
56.6
56.3
63.1
527.7
508.6
446.5
495.4
2.85
1.11
2.65
1.90
13.05
14.66
16.23
14.68
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2585
3374
3773
2.45
1.93
2.23
86
756
1718
247
437
478
160
300
330
130
2.50
2.70
2.30
1. 20
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0904
11/08/73 BAR:24.67 DB:80 WB:56
REL.HUM:22.6% NOX COR: .864
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.15
3.14
4.34
3.89
87.9
56.6
56.3
63. 1
527.7
508.6
446.5
495.4
2.85
1.11
2.65
1.90
13.05
14.66
16.23
14.68
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
2585
3374
3773
2.45
1.93
2.23
86
756
1718
247
437
478
160
300
330
130
2.50
2. 70
2.30
1.20
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 314
1971 FORD BRON 302 3500LBS
8CYL 2BBL 3 SPEED 020440 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
== = :=:
===333 33=
======
========
=== MAINTENANCE STATUS
33 =
S3S33335
=======
=3333 333 3=3 3
I. CO
I.RPM
TIM DWL PCV A
.CL
CHOKE
A.PMP
MISF. NOXC
FROM
OWNER
2.30
-0050
+04 +00 OK
OK
OK
NA
YES NA
FROM
INSP.
1.00
+0300
+01 +03 OK
OK
OK
NA
YES NA
IDLE INSPECTION
STATION NO. 6
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
1800
900
1000
180
2500HC
800
210
400
310
1. CO
2.10
0.60
2. 10
0.30
2500CO
2.00
1. 70
0.50
0.30
FAILURE
HC
HC
HC
PASS
COST
4.50
1.50
3.00
31.57
40.57 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO-.C0906
11/08/73 BAR:24.71 DB:74 WB:53
REL.HUM:25.2% NOX COR: .851
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
10.31
7.71
7.50
8. 19
118. 2
97.5
93.5
100.7
459. 1
495.9
406.2
463.3
2.87
1.53
2.76
2.15
13. 14
13.22
15.44
13.76
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
6787
4340
3773
3.34
3.22
2.73
54
1655
1840
1219
497
457
1000
340
280
1150
2.80
2. 70
2. 30
2.20
*************************
AS RECEIVED FROM
INS PECTION ************************
TEST NO:C0933
11/09/73 BAR
REL.HUM:
:24.84
26.0%
DB : 75
NOX COR
WB:54
: .859
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
9.20
6.01
7.57
7.11
113.2
70.7
72.5
80.1
498.1
516.2
443.0
492. 1
5.00
3. 10
4.82
3.97
12.63
13.78
15.33
13.91
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
1756
3848
3799
0.84
2.02
2.45
80
1907
2676
203
491
456
125
355
320
0.90
1.85
2.30
2500 RPM
1000
2.50
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 315
1971 OLDS CUTL 350 3500LBS
8CYL 4BBL AUTOMATIC 026169 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
FROM OWNER
FROM INSP.
===========««==,=, MAINTENANCE STATUS ===
I.CO I.RPM TIM DUL PCV A.CL
4.50 -0073 +02 -01 OK OK
4.50 -0073 +02 -01 OK OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 2
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/HI ADJ 1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
250
250
2500HC
60
60
I.CO 2500CO
3.60. 0.80
3.60 0.80
FAILURE COST
PASS 5.50
PASS
5.50 TOT.
************* AS RECEIVED FROM OWNER A***************************
TEST NO:C0918
11/09/73 BAR:24.80 DB:69 WB:50
REL.HUM-.26-.47. NOX COR: .836
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.50
3.89
4.63
4.43
81. 1
42.5
63. 1
56.3
619.5
595.8
572.1
594.2
3.93
3.98
5.90
4.50
11.65
13.20
12.98
12.79
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3707
3173
2883
4.84
1.29
0.71
58
2017
3017
360
433
366
250
290
210
80
4.70
1.20
0.75
1.90
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0918
11/09/73 BAR:24.80
REL.HUM:26.4%
DB: 69
NOX COR
WB: 50
: .836
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.50
3.89
4.63
4.43
81. 1
42.5
63.1
56.3
619.5
595.8
572.1
594.2
3.93
3.98
5.90
4.50
11.65
13.20
12.98
12.79
IDLE KEYMODE
LOU CR. KEYMODE
HI. CR. KEYMODE
3707
3173
2883
4.84
1.29
0.71
58
2017
3017
360
433
366
250
290
210
4.70
1.20
0.75
80
1.90
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 316
1970 MERC MONT 302 3500LBS
8CYL 2BBL 3 SPEED 027532 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
FROM OWNER
FROM INSP.
asaaass
MAINTENANCE STATUS
I.CO I.RPM
0.15 -0225
1.20 -0200
TIM DHL
+00 +06
+00 +00
PCV A.CL
BAD BAD
OK BAD
CHOKE
OK
OK
A.PMP
NA
NA
MISF.
YES
YES
NOXC
NA
NA
IDLE INSPECTION
STATION NO. 1
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I. HC
1100
150
150
2500HC
180
180
180
I. CO 2500CO
0.20 0.80
0.20 0.70
0.20
0.70
FAILURE
HC
PASS
PASS
COST
2.50
4.00
6.50 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0919
11/09/73 BAR:24.83 DB:76 WB:52
REL.HUM:18.8% NOX COR: .825
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
8.19
5.79
6.56
6.50
106.4
53.4
70.2
69.2
442.8
522.3
409.4
474.3
1.69
2. 12
2. 17
2.04
14.01
14.26
16.48
14.76
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
5680
4173
4051
0.18
1.39
1.32
70
1568
2390
924
512
526
700
360
350
175
0. 30
1.30
1. 30
1.30
*************************
AS RECEIVED FROM
INS PECTION ************************
TEST NO:C0946
11/12/73 BAR
REL.HUM:
: 24.57
22.5%
DB : 74
NOX COR
WB: 52
: .838
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
8.99
4.64
7.12
6.24
107.5
55.0
71.2
70.5
509.7
535.9
426.8
500.2
3.08
2.27
3.44
2.77
12.60
13.98
15.87
14. 12
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2155
4126
4158
1.33
1.85
1.79
100
1994
2470
222
504
546
110
3 70
380
1.30
1.80
1. 70
2500 RPM
210
1.70
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 317
1971 FORD HAVE 200 2 750LBS
6CYL 1BBL AUTOMATIC 023567 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
FROM OWNER
FROM INSP.
================= MAINTENANCE STATUS ===
I. CO I.RPM TIM DHL PCV A.CL
3.60 +0000 -06 -K)0 OK BAD
3.60 +0000 -06 +00 OK BAD
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA NO NA
STATION NO. 4
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC
245
2500HC
170
245 170
I. CO
1.60
2500CO
0.80
1.60 0.80
FAILURE COST
PASS 5.00
PASS
5.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0921
11/09/73 BAR:24.81 DB:74 WB:52
REL.HUM:22.3% NOX COR: .836
HC
CO
C02
NOX
MPC
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.36
6. 10
4.99
6.06
119.5
116.7
66.0
103.2
454.0
384.3
381.0
398.0
3. 14
1.63
3.40
2.44
13.39
15. 17
17.79
15.38
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
3641
4816
3945
4.05
4.43
1.44
97
730
2522
LHC
SHC
SCO
335
200
3.70
688
560
4.20
507
325
1.21
270
2.40
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0921
11/09/73 BAR:24.81 DB:74 WB:52
REL.HUM:22.3% NOX COR: .836
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
197-5 COMPOSITE
7.36
6. 10
4.99
6.06
119.5
116.7
66.0
103.2
454.0
384.3
381.0
398.0
3. 14
1.63
3.40
2.44
13.39
15. 17
17.79
15.38
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3641
4816
3945
4.05
4.43
1.44
97
730
2522
335
688
507
200
560
325
270
3.70
4.20
1.21
2.40
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 318
1971 FORD GALA 400 4000LBS
8CYL 2BBL AUTOMATIC 040209 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
===='
I==333=
It
I
li
II
n
li
ii
sssssaaaa
== MAINTENANCE STATUS
= = :
I. CO
I.RPM
TIM DWL PCV A
.CL
FROM
OWNER
6.60
+0075
+00 +00 OK
OK
FROM
INSP.
3.90
+0020
405 +00 OK
OK
CHOKE A.PMP MISF. NOXC
OK NA YES NA
OK NA NO NA
IDLE INSPECTION
STATION NO. 9
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
300
200
200
2500HC
200
200
200
I. CO
6.00
3.10
3.10
2500CO
0.20
0.30
0.30
FAILURE
BOTH
PASS
PASS
COST
0.00
0.00
4.00
4.00 TOT.
k A A A A it A A A A A A A A A A * * * * * A A A £ * *
TEST NO:C0922
AS RECEIVED FROM OUNER ***************************
11/09/73 BAR:24.81 DB : 72 WB:51
REL.HUM:23.2% NOX COR: .833
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
6.99
123.2"
718.0
7.95
9.54
COLD STABILIZED
4.80
107.8
649.6
5.78
10.68
HOT TRANSIENT
4.50
63.4
602.9
8.27
12.43
1975 COMPOSITE
5.17
98.7
650.9
6.92
10.83
IDLE KEYMODE
4501
7.07
64
389
285
6. 70
LOU CR. KEYMODE
2532
0.71
3383
295
170
0.65
HI. CR. KEYMODE
2016
0.33
3965
233
100
0.35
2500 RPM
270
0.85
A A A A A A it A A A A A A it A A A A A A it A A A A
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0947
11/12/73 BAR:24.56 DB:74 WB:52
REL.HUM:22.6% NOX COR: .839
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.65
3.98
4.55
4.90
182.8
85. 1
63. 1
99.5
669.4
656.1
650.7
657.4
5.95
4.92
6.90
5.69
9.08
11. 10
11.65
10. 74
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3635
2665
2017
4.31
1.51
0.93
76
2463
3308
326
325
242
260
220
130
120
4.50
1.60
0.85
1.50
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 319
1971 FORD TORI 351 3500LBS
8CYL 2BBL AUTOMATIC 013444 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, N'0 EVC, PCV
========================1====== MAINTENANCE STATUS =======*===========3==========
I.CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 5.10 -0100 +00 +01 OK OK OK NA NO NA
FROM INSP. 2.60 -0010 -H30 -KJ1 OK OK OK NA NO NA
STATION NO. 8
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
250
250
190
190
2500HC
110
120
110
110
I. CO
6. 30
4.80
2.60
2.60
2500C0
1.00
1.00
0.60
0.60
FAILURE
CO
CO
PASS
PASS
COST
3.50
2.00
2.50
8.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0923
11/09/73 BAR:24.85 DB:68 WB:51
REL.HUM:31.9% NOX COR: .855
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO.
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.29
5.31
4.91
5.41
75.7
92.7
57.0
79.3
606.3
564.4
472.2
547.6
5. 13
2.68
4.33
3.65
11.95
12.25
15.43
12.92
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4376
3293
3312
5^31
0.88
1.14
65
2136
2929
392
436
425
310
285
240
170
5.00
0.80
1.00
1. 10
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0948
11/12/73 BAR
REL.HUM:
:24.52
19. 1%
DB: 76
NOX COR:
WB: 52
.828
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.95
4.68
5.97
5.51
98.8
79. 1
68. 1
80.2
588.5
527.6
469.8
524.3
4.23
2.53
3.95
3.28
11.63
13.36
14.95
13.34
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
3114
3083
3137
2.70
0.74
1.15
72
2109
3019
275
350
339
215
270
240
140
2.50
0.75
1. 10
1.20
AUTOMOTIVE TESTINC LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 320
1973 FORD MUST 351 3500LBS
8CYL 2BBL AUTOMATIC 003445 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, EVC, PCV
=============
======
========
===> MAINTENANCE STATUS
I. CO
I.RPM
TIM DWL PCV A,
.CL
FROM OWNER
6.00
+0055
-08 +00 OK
OK
FROM INSP.
6.00
+0055
-08 +00 OK
OK
CHOICE A.PMP MISF. NOXC
OK NA NO BAD
OK NA NO BAD
STATION NO. 10
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC
190
2500HC
100
190 100
I. CO
3.00
2500CO
1. 10
3.00 1.10
FAILURE COST
PASS 1.50
PASS
1.50 TOT.
*************************** as RECEIVED FROM OWNER ***************************
TEST NO:CO924
11/09/73 BAR:24.81 DB:70 WB:51
REL.HUM:27.4% NOX COR: .844
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.28
5.02
4.36
4.89
98.6
134.5
83.4
112.8
572.4
513.8
442.6
506.3
1.83
0.99
1.71
1.37
11.97
12.02
15. 16
12.74
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
5642
2981
2819
6.46
2. 14
1.73
51
1074
1360
485
410
382
350
280
230
190
5.80
2.00
1. 70
2.40
*************************
AS RECEIVED FROM
INSPECTION ************************
TEST NO:C0924
11/09/73 BAR
REL.HUM:
: 24.81
27.4%
. DB:70
NOX COR
WB: 51
: .844
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5.28
5.02
4.36
4.89
98.6
134.5
83.4
112.8
572.4
513.8
442.6
506.3
1.83
0.99
1.71
1.37
11.97
12.02
15. 16
12.74
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
5642
2981
2819
6.46
2. 14
1.73
51
1074
1360
485
410
382
350
280
230
190
5.80
2.00
1. 70
2.40
AUTOMOTIVE
TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 321
1970 CHEV NOVA 250 3500LBS
6CYL 1BBL AUTOMATIC 012130 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
MAINTENANCE STATUS
FROM OWNER
FROM INSP.
I.CO I.RPM
4.70 +0050
4.70 +0050
TIM DWL
-02 +00
-02 +00
PCV
OK
OK
A.CL
BAD
BAD
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK ¦ NA NO NA
IDLE INSPECTION
STATION NO. 3
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ 1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
75
75
2500HC
25
25
I. CO
0.30
0.30
2500CO
0. 10
0. 10
FAILURE
PASS
PASS
COST
0.00
6.00
6.00 TOT.
*************************** AS RECEIVED FROM OWNER ***************************
TEST NO:C0935
11/12/73 BAR:24.73 DB:73 WB:50
REL.HUM:18.6% NOX COR: .816
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
6.04
115.5
558.5
3.80
11.73
COLD STABILIZED
3.14
42.7
539.5
2.58
14.44
HOT TRANSIENT
2.78
40.2
493.3
4.10
15.75
1975 COMPOSITE
3.65
57.2"
530.7
3.26
14.09
IDLE KEYMODE
3421
5.09
90
392
345
4. 70
LOW CR. KEYMODE
2644
0.83
2139
238
155
0.85
HI. CR. KEYMODE
2679
1.43
2324
258
145
1.45
2500 RPM
80
1.35
*************************
AS RECEIVED FROK
INSPECTION ************************
TEST NO:C0935
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
11/12/73 BAR:24.73 DB:73 WB:50
REL.HUM:18.6% NOX COR: .816
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
6.04
3.14
2.78
3.65
115.5
42.7
40.2
57.2
558.5
539.5
493.3
530.7
3.80
2.58
4. 10
3.26
11.73
14.44
15. 75
14.09
3421
2644
2679
5.09
0.83
1.43
90
2139
2324
392
238
258
345
155
145
80
4.70
0.85
1.45
1.35
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 322
1970 CHEV NOVA 307 3500LBS
8CYL 2BBL AUTOMATIC 032511 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
MAINTENANCE STATUS =========
FROM OWNER
I. CO
7.40
I.RPM
-0025
TLM
-02
DUL
-08
PCV
OK
A.CL
OK
CHOKE A.PMP MISF.
OK
NA
NO
NOXC
NA
FROM INSP. 3.40
-0100
-01 -07
OK
OK
OK iNA
YES NA
STATION NO. 7
I.HC
2500HC
I. CO
2500CO
FAILURE
COST
INITIAL INSPECTION
860
820
8.20
6. 10
BOTH
2.50
AFTER I.RPM ADJUST
860
820
8. 10
6.00
BOTH
2.50
AFTER I.MX/TM ADJ1
460
300
2.30
2.30
PASS
2.50
AFTER I.MX/TM ADJ2
REPAIRS
2.50
FINAL INSPECTION
460
300
2.30
2. 30
PASS
10.00 TOT.
***************************
AS RECEIVED
FROM OWNER ***************************
TEST NO:C0936
11/12/73
BAR:24. 72
DB : 73 WB:50
REL.HUM:18.6% NOX COR: .816
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
10.06
7.74
5.74
7.67
109.4
78.4
59.8
79.7
412.5
412.3
358.6
397.5
2.80
2.57
3.53
2.88
14.45
15.90
18.92
16.28
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
7291
4197
3847
8.97
0.88
1.78
50
2229
2152
916
557
466
750
430
320
190
7.35
1.05
1.70
1.70
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0964
11/13/73 BAR:24.49 DB:70 WB:51
REL.HUM:27.7% NOX COR: .847
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
8.52
5.44
5.45
6.09
112.6
47.5
61.8
65.1
437.3
432.8
394.7
423.2
3. 13
2.88
3.50
3.10
13.89
16.97
17.49
16.35
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
5726
4270
4026
4.12
1.00
2.64
55
2391
2014
576
536
453
490
420
330
450
3.20
0.90
2.40
1. 10
AUTOMOTIVE TESTING@LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 323
1970 PONT TEMP 350 3500LBS
8CYL 2BBL AUTOMATIC 030849 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, NO EVC, PCV
============================== MAINTENANCE STATUS ==============================
I. CO I.RPM TLM DHL PCV A.CL
FROM OWNER 8.50 +0025 +01 -03 OK BAD
FROM INSP. 4.10 +0000 +00 -03 OK OK
CHOKE A.PMP MISF. NOXC
OK NA NO NA
OK NA YES NA
IDLE INSPECTION
STATION NO. 6
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
600
590
270
250
2500HC
120
160
160
160
I. CO
8.20
8.00
4. 20
2.60
2500CO
2.40
4.00
3.80
4.00
FAILURE
BOTH
BOTH
CO
PASS
COST
4.50
1.50
1.50
18.54
26.04 TOT.
* ******************** ** **** AS RECEIVED FROM OWNER ***************************
TEST NO:C0937
11/12/73 BAR: 24. 71 DB:73 WB:50
REL.HUM:18.7% NOX COR: .816
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
20.34
22.78
12.51
19.42
206.8
248.9
160.3
215.5
477.9
480.4
393. 1
455.7
2.70
1.91
2.67
2.29
10.27
9.44
13.01
10.41
11538
5488
3999
8.77
7.62
3.87
204
1394
2063
785
686
457
720
530
295
175
8.20
6.70
3.45
5.00
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0965
11/13/73 BAR:24.50 DB:76 WB:54
REL.HUM:24.4% NOX COR: .857
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
9.53
5.66
5.05
6.30
148.7
147.8
107.2
136.7
508.4
522.0
424.0
4 92.0
2.50
1.63
2.39
2.02
11.53
11.53
14.64
12.26
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4046
4334
3527
4.61
6.08
3.75
82
794
2070
461
568
411
250
400
260
120
4.00
4.70
3. 10
3.60
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX," AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 324
1973 CHEV NOVA 250 3500LBS
6CYL 1BBL 3 SPEED 004682 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, EVC, PCV
============================== MAINTENANCE STATUS ==============================
FROM OWNER
FROM INSP.
I.CO I.RPM
0.95 +0060
0.95 +0060
TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
-01 +01 OK BAD OK NA NO ' OK
-01 +01 OK BAD OK NA NO OK
IDLE INSPECTION
STATION NO. 8
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
80
80
2500HC
50
50
I. CO
0.50
0.50
2500CO
0.50
0.50
FAILURE
PASS
PASS
COST
3.50
3.50 EST.
3.50 TOT.
**************** *********** Ag RECEIVED FROM OWNER ***************************
TEST NO:C0939
11/12/73 BAR:24.70 DB:77 WB:52
REL.HUM:17.3% NOX COR: .821
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.28
2.57
3.20
3.73
90. 1
47. 1
52.4
57.5
539.0
626.9
478.0
567. 2
1.60
1.10
1.73
1.38
12.66
12.56
15.61
13.31
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
788
968
537
1.32
0.94
1.09
67
490
869
122
171
138
40
50
30
25
0.95
0.80
0.95
0.32
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0939
11/12/73 BAR:24.70 DB:77 WB:52
REL.HUM:17.3% NOX COR: .821
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
7.28
90.1
539.0
1.60
12.66
COLD STABILIZED
2.57
47.1
626.9
1. 10
12.56
HOT TRANSIENT
3.20
52.4
478.0
1.73
15.61
1975 COMPOSITE
3.73
57.5
567.2
1. 38
13.31
IDLE KEYMODE
788
1.32
67
122
40
0-95
LOW CR. KEYMODE
968
0.94
490
171
50
0.80
HI. CR. KEYMODE
537
1.09
869
138
30
0.95
2500 RPM
25
0.32
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 325
1973 FORD GALA 351 4500LBS
8CYL 2BBL AUTOMATIC 016385 MILES
HIGH ALTITUDE RETROFIT
HAS: EMC, EVC, PCV
FROM OWNER
FROM INSP.
: = = ===
ii
u
ii
ii
n
ii
ii
ii
===» MAINTENANCE STATUS
S333SBSS3SS
sassaas
ii
ii
ii
ii
u
ii
SS333SS
I. CO
I. RPM
TIM DWL PCV A.
,CL CHOKE
A. PMP
MISF.
NOXC
5.50
+0020
+02 +00 OK
OK OK
NA
NO
OK
5.50
+0020
+02 +00 OK
OK OK
NA
NO
OK
STATION NO. 10
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
IDLE INSPECTION
I.HC
150
150
2500HC
70
70
I. CO
2.60
2500CO
1. 10
2.60 1.10
FAILURE COST
PASS 1.50
PASS
1.50 TOT.
*************************** as RECEIVED FROM OWNER ***************************
TEST NO:C0938
11/12/73 BAR:24. 71 DB:77 WB:52
• REL.HUM:17.3% NOX COR: .821
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.48
5.43
5.37
5.84
117.7
112.7
86.9
106. 6
591.9
604. 1
520.4
578.3
2.16
1.89
2.25
2.05
11.13
11. 16
13.22
11.66
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4013
3681
3199
5.85
2.00
2.09
88
1943
1125
454
454
372
0
375
335
250
170
5.00
1.85
1.95
2.40
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0938
11/12/73 BAR:24.71 DB:77 WB:52
REL.HUM:17.3% NOX COR: .821
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
7.48
5.43
5.37
5.84
117.7
112.7
86.9
106.6
591.9
604.1
520.4
578.3
2. 16
1.89
2.25
2.05
11.13
11. 16
13.22
11.66
IDLE KEYMODE
LOU CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4013
3681
3199
5.85
2.00
2.09
88
1943
1125
454
454
372
375
335
250
170
5.00
1.85
1.95
2.40
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 326
1969 TOYO CORO 116 2500LBS
4CYL 2BBL 4 SPEED 076050 MILES
IDLE INSPECTION ONLY
HAS: EMC, MO EVC, NO PCV
MAINTENANCE STATUS
I.CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 3.50 -0175 -08 +00 NA BAD OK NA YES NA
FROM INSP. 0.70 -0100 -07 +02 NA BAD OK NA YES NA
STATION NO. 5
INITIAL INSPECTION
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION
I.HC
860
1140
140
140
2500HC
590
800
280
280
I. CO
0.70
1.00
1.20
1.20
2500CO
1.60
1.80
1.50
1.50
FAILURE
HC
HC
PASS
PASS
COST
5.50
5.50
5.50
35.50
52.00 TOT.
is it is A is A * it A * A A it it it it is * it it A is -J: * A
TEST NO:C0952
** AS RECEIVED FROM OWNER ***************************
11/13/73 3AR:24.50 DB:75 WB:52
REL.HUM:20.8% NOX COR: .834
HC
CO
CO 2
NOX
MI'G
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
5. 16
7.09
6.76
6.59
120.7
156.9
170.9
153. 2
328. 3
348.0
261.9
320.0
2.69
1.44
0.84
1.54
16.67
14.43
16. 14
15. 32
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
4433
5320
4169
3.66
11.22
11.06
34
196
275
301
678
508
210
360
250
750
3. 20
8.40
9.10
3.60
0
AS RECEIVED FROM
INSPECTION ****
&-k'A*A
;'c * % *
TEST NO:C0981
11/14/73 BAR
REL.HUM:
:24.51
16.8%
DB : 71
NOX COR:
UB: 48
.803
HC
CO
CO 2
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
4.70
3.89
5.01
4.37
141.3
149.2
150. 2
147.8
288.3
350. 1
277.6
317. 1
1. 32
0.76
1.01
0.95
16.95
14.92
16.82
15.82
IDLE KEYMODE
LOU CR. KEYMODE
HI. CR. KEYMODE
2796
1567
2639
1.00
4.41
6.40
90
522
1100
439
234
324
150
80
140
0.50
3.40
4.70
1500 RPM
210
1. 60
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
*** COLORADO-393 ***
VEHICLE 327
1970 TOYO CORO 113 2500LBS IDLE INSPECTION ONLY
4CYL 2BBL 4 SPEED 051836 MILES HAS: EMC, NO EVC, PCV
aaaaiiBassaasaaoaasiaaaaaasaaaa MAINTENANCE STATUS sscsiaaaaaaasassassassaaaaaaasss
I.CO I.RPM TIM DWL PCV A.CL CHOKE A.PMP MISF. NOXC
FROM OWNER 0.21 +0200 -K)5 -02 OK OK OK NA YES NA
FROM INSP. 0.15 +0270 -04 -05 OK OK OK NA YES NA
STATION NO. 5
I.HC 2500HC I. CO 250OCO FAILURE COST
INITIAL INSPECTION 700 120 0.20 0.30 HC 5.50
AFTER I.RPM ADJUST
AFTER I.MX/TM ADJ1
AFTER I.MX/TM ADJ2
REPAIRS
FINAL INSPECTION 700 120 0.20 0.30 HC 45.00 EST.
5.50 TOT.
*************************** A.S RECEIVED FROM OWNER ***************************
TEST NO:C0978
11/14/73 BAR
REL.HUM:
: 24.46
17.9%
DB: 72
NOX COR
WB: 49
: .811
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
8.29
4.92
4.46
5.50
135.8
42.0
42.5
61.7
337.2
399. 1
324.8
365.6
2.49
3.19
3.24
3.06
15.44
18.53
21.95
18.56
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
5732
2697
2703
0.32
0.21
0.39
132
2299
3654
855
302
310
400
510
160
110
0.25
0.20
0.40
0.20
************************* AS RECEIVED FROM INSPECTION ************************
TEST NO:C0982
11/15/73 BAR:24.77 DB:75 WB:49
REL.HUM:12.7% NOX COR: .793
HC
CO
C02
NOX
MPG
LHC
SHC
SCO
COLD TRANSIENT
COLD STABILIZED
HOT TRANSIENT
1975 COMPOSITE
6.68
3.44
3.23
4.06
88.4
16.1
23.6
33.3
334.3
433.6
343.1
387.7
2.33
4.09
3.38
3.53
18.02
18.96
22.81
19.67
IDLE KEYMODE
LOW CR. KEYMODE
HI. CR. KEYMODE
2500 RPM
1726
2205
2693
0.23
0.27
2.00
186
1834
2888
227
258
319
170
130
170
145
0. 19
0.27
1.80
2.00
AUTOMOTIVE TESTING LABORATORIES,INC.
19900 E. COLFAX, AURORA, COLO. 80011
-------
-------
CONTENTS OF APPENDICES
Appendix No. Description Page
1. Federal Test Procedure Equations 314
2. Derivation of Fuel Consumption Equation 315
3. Maintenance Status Determination 316
-------
RULES AND REGULATIONS
17161
(a) For light duty vehicles:
v.»=(o.43 y.i+o,a7y»i+7.)/7j
where:
y«„=Weighted mass emissions of each,
pollutant. I.e. HC, CO, or NO«, la
grams per vehicle mile.
Y«i= Mass emissions as calculated from
the "transient" phase of the cold
start test, in grams per test phase.
Y\i ~ Mass emissions as calculated from
the "transient" phase of the hot
start test. In grama per test phase.
r«=Mass emissions as calculated from
the "stabilized" phase of the cold
start test. In grams per test phase.
(b) The mass of each pollutant for
each phase ol both the cold start test and
the hot start test la determined from the
following:
(1) Hydrocarbon Mass:
= Vmi.xDensltyscX
HC.~.
1,000,000
(2) Oxides of nitrogen Mass:
= F-"X Densityjo.x^^jx Ka
(3) Carbon monoxide Mass:
CO =7 m i* X Density™ X
(c) Meaning of symbols:
COfnm
1.000.000
HCmtt, =Hydrocarbon emissions. In grama
per test phase.
Denaltyuc=Density of hydrocarbons In the
exhaust gas, assuming an aver-
age carbon to hydrogen ratio of
1:1.33. In grams per cubic foot
at 68* F. and 760 mm. Hg pres-
sure (18J3 gzn./cu. ft).
HCe»nt=Hydrocarbon concentration of the
dilute exhaust sample corrected
for background, in p.pja. car-
bon. equivalent, I.e. equivalent
propane x 3.
SC....=H C.—HC* (1 - l/DF)
where:
HC.=Hydrocarbon concentrations of
- the dilute exhaust sample as
measured. In p.pjn. carbon
equivalent.
HCi—Hydrocarbon concentration of
the dilution air as measured
. In p.p.m. carbon equivalent.
JVO»„.,t = Oxides of nitrogen emissions,
in grams per test phase.
Densltyyo,=Oen3lty of oxides of nitrogen
In the exhaust gas, assum-
ing they are In. the form of
nitrogen dioxide. In grams
per cubic foot at 68" F. and
760 mm. Hg pressure (54.18
gm./cu.ft.).
WO»„„,=Oxldes of nitrogen concentra-
tion of the dilute exhaust
sample corrected for back-
ground. in p.p jn..
NO,0^=XO,.-NO,i(l-\/DF)
where:
iVO»,=Oxlde3 of nitrogen concentra-
tion of the dilute exhaust
sample as measured. In p.p.m.
iVO^r: Oxides of nitrogen concentra-
tion of the dilution air as
measured. In p.pjn.
(70mu>=Carbon monoxide emissions. In
grams per test phase.
Denslty?p=Density of carbon monoxide In
grams per cubic foot at 68* P.
and 760 mm. Hg pressure
(32.97 gm./cu. ft.).
CO»M=Carbon monoxide concentration
of the dilute exhaust sample
corrected for background,
water vapor and CO, extrac-
tion, In p.pjn.
CO««w=CO.—<704(1 —l/DP)
where:
COi=Carbon monoxide concentration of.
the dilute exhaust sample volume
corrected for water vapor and car-
bon dioxide extraction. In p.pjn.
The calculation assumes the car-
bon to hydrogen ratio of the fuel
Is 1:1.85.
CO. = (1 -0.01925CO».—0.000323B) COtm.
where:
CO.n= Carbon monoxide concentration of
the dilute exhaust sample as
measured in p.p.m.
COn =Carbon dioxide concentration of
the dilute exhaust sample, in
mole percent.
5=Relative humidity of the dilution
air, m percent.
COj=Carbon monoxide concentration of
the dilution air corrected for
water vapor extraction, in p.pjn.
COiss (1 -0.000333a) COtm
where:
CO=Barometric pressure In mm. Hg.
Pi =:Pressure depression below atmosphere
measured at the inlet to the positive
displacement pump.
Tt=Average temperature of dilute exhaust
entering positive displacement
pump during test while samples are
being collected, in degrees Ranklne.
Ks—Humidity correction factor.
Ka~ 1-0.0047 {H—75)
where:
H—Absolute humidity in grains of water
per pound of dry air.
(43.478) lUXPt
Pt—{P*XR*/100)
AaslMatlve humidity of the ambient air.
In percent.
Saturated vapor pressure. In mm. Hg
at the ambient dry bulb tempera-
ture.
(d) Example calculation of mass
emission values:
(1) For the "transient" phase of the
cold start test assume 7^=0.29344 cu. ft.
per- revolution; 10,485; 48.0%:
¦R.=48.2%: Pt=762 mm. Hg: Pt=22.225
mm. Hg; Pi=70 mm. Hg; rP=570°.R;
HC.=> 105.8 p.pjn. carbon equivalent;
NOz.= 11.2 p.pjn.: CO.«=306.8 p.p.m.;
CO,.=1.43%; HC4= 12.1 p.pjn.; NOu
=0.8 p.pjn.; CO<«=15.3 p.pjn. Then:
Vmit —
H=
Kb=
(0.29344) (10,485) (762 - 70) (528)
' — -=2593.0 cu. ft. per test phase.
(760) (570)
(43.478) (48.2) (22.225)
762 - (22.225 X 482/100)
1
=0.9424.
1—0.0047(62 — 75)'
CO.= (1-0.01925(1.43) -0.000323(48))306.0 =293.4 p.pjn.
CO*-(1-0.000323(48) >15.3 = 15.1 p.pJB.
13.4
DF=-
-=9.118.
I.43+(105.8+293.4) X10"»"
105.8-12.1(1 — 1/9.116) =95.03.
: (2595) (16.33) (95.03/1,000,000) =4.027 grams per test phase.
II.2-0.8(1 —1/9.116) =10.49.
: (2595) (54.16) (10.49/1.000.000) (0.9424) =1.389 grams per test phase.
293.4-15.1(1-1/9.116) =280.
CO-.,, = (2595) (33.97) (280/1,000,000) =23.96 grams per test phase.
(2) For the "stabilized" portion of the hot start test assume that similar calcu-
HCcon*~
HC nil. -
wo».».=
COcone -
cold start test assume that similar calcu-
lations resulted in HC«,„.=0.52 grams
per test phase: NO«™..,=1.27 grams per
test phase; and CO man-*5< 98 grams per
test phase.
(3) For the "transient" portion of the
lations resulted in HC Bill =0.51 grams
per test phase; NOm...1.28 grams per
test phase; and COm...=5,01 grams per
test phase.
(4) For a 1975 light duty vehicle:
HC,m = { (0.43) (4.027) + (0.57) (0.51) + 0.62)/7.5=0.352 gram per vehicle mile.
NO.,m= ((0.43) (1.389) + (0.57) (1.38) + 1.27) 77.5=0.354 gram per vehicle mile.
CO„„ = ( (0.43) (23.36) +(0.57) (5.01) +5.98)/7.5=2.55 grams per vehicle mile.
§ 35.073—27 Calculations (fuel evapora.
tive emissions).
The net weights of the individual col-
lection traps employed in § 85.075-13
shall be added together to determine
compliance with the fuel evaporative
emission standard.
§ 85.075—28 Compliance with emission
standards.
(a) The exhaust and fuel evapora-
tive emission standards in 3 85.075-1
apply to the emissions of vehicles for
their useful life.
(b) Since emission control efficiency
decreases with mileage accumulated on
the vehicle, the emission level of a ve-
hicle which has accumulated 50,000
miles will be used as the basis for
determining compliance with the
standards.
(c) The procedure for determining
compliance of a new light duty motor
vehicle with exhaust and fuel evaporative
emission standards is as follows:
Ha. 124—Pt. HI-
FEDERAL REGISTER, VOL 38, MO. 124—THURSDAY, JUNE 28, 1973
-------
APPENDIX 2.
FUEL CONSUMPTION
The fuel consumption, in miles per gallon, for the Federal Test
Procedure can be calculated using a carbon balance equation and the
mass emissions found during the test.
If the hydrogen to carbon ratio in the fuel is assumed to be
1.85 then the combustion process can be explained by some chemical
formula of the form:
^1.85 + °2~"* CH1.85 + co + C02 + H2°
The carbon constituent of each of the above is known as follows:
1 gram CO contains 12.011/28.010 gram carbon
1 gram CO2 contains 12.011/44.010 gram carbon
1 gram CHj^g5 contains 12.011/13.875 gram carbon
The chemical formula yields a carbon balance equation in which the
carbon in the fuel equals the carbon in the tailpipe exhaust
. _ 12.011 _ „„ 12.011 , _ 12.011 . _ 12.011
A x 13.875 C x 13.875 C0 * 28.010 C02 x 44.010
where,
A » fuel used (hydrocarbons), in grams per mile
HC ¦ unburned hydrocarbons in exhaust, in grams per mile
CO ¦ carbon monoxide in exhaust, in grams per mile
CO2 *» carbon dioxide in exhaust, in grams per mile
simplifying
A «¦ HC + 0.4954 x CO + .3153 x C02
The density of gasoline is 2808 grams per gallon, so converting grams
per mile to miles per gallon yields
MPG - 2808/(HC + 0.4954 CO + 0.3153 C02)
-------
Maintenance Status Determination
1. Air Pump - With the engine running, the air pump hose is pulled
off. If air is flowing, the pump is assumed to be working. With
the engine off the belt tension is checked for sufficient tension
to drive the pump at high speed.
2. Idle RPM and dwell will be measured with a Kal-equip model T-lll
Dwell-Tach tester.
3. Timing will be measured with a Kal-equip model L-10 timing light.
4. The PCV test procedure is as follows:
Remove PCV from valve cover, note RPM. Cover valve inlet, again
note RPM. If the system is working properly, the RPM should fall
off at least 50 RPM when the inlet is covered.
5. The air cleaner is assumed to be OK if it is not oil soaked or
excessively dusty.
6. The choke is assumed to be OK if the heat riser is not bent and
is operating freely, and if the vacuum kick responds to vacuum and
is operating freely.
7. The idle CO will be measured with a Beckman Model 315A NDIR CO
analyzer, during Keymode idle.
8. Misfire will be noted by monitoring HC and CO as the car is being
accelerated to Keymode low cruise.
9. NOX Control - The distributor vacuum advance will be examined at
Keymode low cruise and at Keymode high cruise. At low cruise,
there should be no vacuum; at high cruise, there should be vacuum
to the distributor.
------- |