                  The Performance of Selected
                  Radiological Decontamination
                  Processes on Urban Substrates
                  TEST/QA PLAN
   Office of Research and Development
   National Homeland Security Research Center

-------

-------
  Baneiie
7/7(2 Business of Innovation
 National Homeland Security
 Research Center
Technology Testing and
Evaluation Program

Test/QA Plan for
The Performance of Selected
Radiological Decontamination
Processes on Urban Substrates

-------
Al
                         Radiological Decontamination Processes Test/QA Plan
                                                    Date: 9/10/07
                                                     Version: 1.0
                                                     Page 2 of 33
TITLE AND APPROVAL PAGE
                                 Test/QA Plan

                                     for

     EVALUATION OF THE PERFOMANCE OF SELECTED RADIOLOGICAL
          DECONTAMINATION PROCESSES ON URBAN SUBSTRATES
                                  Version 1.0
                              September 10, 2007
                   >»^-*,*_—-
 John Brake
 U.S. EPA Task Order Project Officer
                                       Date
                                                               '2.
 Eletha Brady-Roberts
 NHSRC Quality Assurance Manager
                                       Date
                                                  
-------
                  Radiological Decontamination Processes Test/QA Plan
                                                     Date: 9/10/07
                                                      Version:  1.0
                                                      Page 3 of 33
This page intentionally blank.

-------
                                               Radiological Decontamination Processes Test/QA Plan
                                                                              Date: 9/10/07
                                                                               Version:  1.0
                                                                               Page 4 of 33
                             A2     TABLE OF CONTENTS
                                                                                    Page
A      PROJECT MANAGEMENT	2
Al     Title and Approval Page	2
A2     Table of Contents	4
A3     Distribution List	5
A4     Technology Evaluation Organization	7
A5     Background	12
A6     Technology Evaluation Description and Schedule	12
A7     Quality Objectives	13
A8     Special Training/Certification	14
A9     Documentation and Records	14

B      MEASUREMENT AND DATA ACQUISITION	16
Bl     Experimental Plan and Test Samples	16
B2     Reference Sample Collection	24
B3     Sample Handling and Identification	24
B4     Analytical Methods	25
B5     Quality Control Requirements	25
B6     Instrument/Equipment Testing, Inspection, and Maintenance	26
B7     Instrument Calibration and Frequency	26
B8     Inspection/Acceptance of Supplies and Consumables	27
B9     Non-Direct Measurements	27
BIO    Data Management	27

C      ASSESSMENT AND OVERSIGHT	29
Cl     Assessments and Response Actions	29
C2     Reports to Management	30

D      DATA VALIDATION AND USABILITY	31
Dl     Data Review, Validation, and Evaluation Requirements	31
D2     Validation Methods	31
D3     Reconciliation with User Requirements	31

E    REFERENCES	33

Figures and Table
Figure 1         Organization Chart for Radiological Decontamination Evaluation	8
Figure 2         Example Cement Coupon with Identification Marking	17
Figure 3         Diagram of the Aerosol Delivery System	19
Figure 4         Gamma Counting Equipment At The INL RML	20
Figure 5         Schematic Diagram of Front And Side View of Test Stand Face	21
Figure 6         Radiological Control Hood	23
Figure 7         Glovebox	23

Table 1          Replicate Concrete Test Coupons for Each Decontamination Technology	22

-------
                                             Radiological Decontamination Processes Test/QA Plan
                                                                           Date: 9/10/07
                                                                           Version: 1.0
                                                                           Page 5 of 33
A3    DISTRIBUTION LIST

Mr. John Drake
Ms. Eletha Brady-Roberts
U.S. EPA National Homeland Security
  Research Center
26 West Martin Luther King Drive
Cincinnati, Ohio 45268

Dr. Ryan James
Ms. Karen Riggs
Mr. Zachary Willenberg
Battelle
505 King Avenue
Columbus, Ohio 43201-2693

Mr. Eric Koglin
U.S. EPA National Homeland Security
  Research Center
944 East Harmon Avenue
Las Vegas, NV 89119

Dr. Robert Fox
Idaho National Laboratory
P.O. Box 1625 MS 2208
Idaho Falls, ID 83415

-------
                                                Radiological Decontamination Processes Test/QA Plan
                                                                                 Date: 9/10/07
                                                                                 Version: 1.0
                                                                                 Page 6 of 33
List of Abbreviations
ANSI          American National Standards Institute
ASTM         American Society for Testing and Materials
BG            Background
cm            Centimeters
DARPA        Defense Advanced Research Projects Agency
DF            Decontamination factor
DOD          Department of Defense
EPA           U.S. Environmental Protection Agency
IEEE          Institute of Electrical and Electronics Engineers
INL           Idaho National Laboratory
LRB           Laboratory record book
NHSRC        National Homeland Security Research Center
ORD          Office of Research and Development
QA            Quality assurance
QC            Quality control
QMP          Quality management plan
%R            Percent removal
ppm           Parts per million
ROD          Radiological dispersion device
RH            Relative humidity
RML          Radiological Measurement Laboratory
RTL           Radiochemistry technical lead
TOL           Task Order Leader
TOPO         Task Order Proj ect Officer

-------
                                               Radiological Decontamination Processes Test/QA Plan
                                                                              Date: 9/10/07
                                                                               Version: 1.0
                                                                               Page 7 of 33
A4    TECHNOLOGY EVALUATION ORGANIZATION
       The technology evaluation will be performed by Battelle with assistance from Idaho
National Laboratory (INL) under the direction of U.S. Environmental Protection Agency's
(EPA) National Homeland Security Research Center (NHSRC) through the Technology Testing
and Evaluation Program (TTEP), with input from the vendors whose decontamination
technologies will be evaluated. The organization chart in Figure 1 shows the individuals from
Battelle, INL, the vendor companies, and EPA who will have responsibilities in the technology
evaluation. The specific responsibilities of these individuals are detailed below.


A4.1   Battelle
       Dr. Ryan James is Battelle's Task Order Leader (TOL) for this technology evaluation. In
that role, Dr. James will oversee the evaluation of the radiological decontamination technologies.
Dr. James's responsibilities are to:
       •  Maintain communication with EPA's Task Order Project Officer (TOPO) on all
          aspects  of the program
       •  Select the appropriate laboratory for the evaluation
       •  Coordinate with vendor representatives to facilitate receipt and operation of the
          radiological decontamination technologies as well as the review of the draft test/QA
          plan and report
       •  Prepare and revise the draft test/QA plan
       •  Review and revise the draft evaluation reports
       •  Establish a budget and schedule for the technology evaluation and direct the effort to
          ensure that budget and schedule are met
       •  Assure that the evaluation is conducted according to this test/QA plan
       •  Keep the Battelle TTEP Manager informed of progress and/or difficulties in planning
          and conducting the evaluation
       •  Coordinate with the Battelle Quality Assurance (QA) Manager for the performance of
          technical and performance audits as required by Battelle or EPA Quality Management
          staff
       •  Respond to any issues raised in QA assessment reports and audits, including
          instituting corrective action as necessary
       •  Coordinate distribution of final test/QA plan and evaluation reports.

-------
     NHSRC
   QA Manager
 E. Brady-Roberts
                         EPA
                      Task Order
                     Project Officer
                       J. Drake
                                              Radiological Decontamination Processes Test/QA Plan
                                                                             Date: 9/10/07
                                                                              Version: 1.0
                                                                              Page 8 of 33
Battelle TTEP
  Manager
  K. Riggs
 Task Order
   Leader
  R. James
                                            Idaho National
                                             Laboratory
                                               R. Fox
   Battelle
 Management
    Vendor
Representatives
Figure 1.  Organization Chart for Radiological Decontamination Evaluation
will:
       Ms. Karen Riggs is Battelle's TTEP Manager. As such, Ms. Riggs will:

       •  Monitor adherence to budgets and schedules in this work
       •  Maintain regular communication with the EPA TTEP Program Manager on program
          level issues and provide oversight of Dr. James and the rest of the evaluation staff
       •  Provide the TOPO with monthly technical and financial progress reports
       •  Review the draft test/QA plan and approve the final version
       •  Review the draft evaluation reports
       •  Ensure that necessary Battelle resources, including staff and facilities, are committed
          to the technology evaluation
       •  Ensure that vendor data is not shared with other participating vendors prior to
          publication of results
       •  Issue stop work order if health and safety of workers or quality of work is
          compromised
       •  Support Dr. James in responding to any issues raised in QA assessment reports and
          audits.

       Mr. Zachary  Willenberg is Battelle's QA Manager for TTEP. As such, Mr. Willenberg
       •  Review the draft test/QA plan and approve the final version
       •  Conduct himself, or appoint a designee, to perform a technical systems audit (TSA) at
          least once during the technology evaluation
       •  Audit at least 10% of the evaluation data

-------
                                                  Radiological Decontamination Processes Test/QA Plan
                                                                                 Date: 9/10/07
                                                                                  Version:  1.0
                                                                                  Page 9 of 33

         •   Prepare and distribute an assessment report for each audit
         •   Verify implementation of any necessary corrective actions
         •   Notify Battelle's TTEP Manager to issue a stop work order if internal audits indicate
             that data quality is being compromised
         •   Provide a summary of the Q A/quality control (QC) activities and results for the
             evaluation reports
         •   Review the draft evaluation reports
         •   Ensure that all quality procedures specified in this test/QA plan and in the QMP1 are
             followed.

         Dr. Robert Fox is the Idaho National Laboratory (INL) radiochemistry technical lead
   (RTL) who will coordinate the experimental work that is conducted at INL during this
   evaluation.  In that role, he will:
         •   Assist in the development of the test/QA plan for the evaluation
         •   Determine the schedule for the experimental work
         •   Direct the INL staff in carrying out the evaluation procedures specified in this
             test/QA plan
         •   Provide the Battelle TOL a weekly status report via phone and a written monthly
             report describing the progress of the experimental work
         •   Ensure that all quality assurance measures dealing specifically with measuring
             radionuclides are followed
         •   Assist in drafting the evaluation reports.

Evaluation staff will include INL staff that will perform the experimental work in the laboratory.  In
   that role, they will:
         •   Review the final version of the test/QA plan
         •   Perform the evaluation of the radiological decontamination technologies as described
             in the test/QA plan and as directed by Dr. Fox.

   A4.2  Vendors
          Vendors that volunteer radiological decontamination technologies for evaluation will:
         •   Review the draft test/QA plan and final version prior to the evaluation of their
             radiological decontamination technologies
         •   Sign a vendor agreement specifying the respective responsibilities of the vendor and
             of Battelle in the evaluation
         •   Provide radiological decontamination technologies for use during the evaluation
         •   Review the draft evaluation report specific to their technology.

   A4.3  EPA
           Mr. John Drake is the EPA's TOPO for this program. As such, Mr. Drake will:

-------
                                              Radiological Decontamination Processes Test/QA Plan
                                                                             Date: 9/10/07
                                                                             Version: 1.0
                                                                             Page 10 of 33

       •  Have overall responsibility for directing the evaluation process under the oversight of
          the TTEP Program Manager
       •  Review the draft test/QA plan and approve the final version
       •  Coordinate involvement of the NHSRC QA Manager
       •  Review the draft evaluation reports
       •  Oversee the EPA review process on the draft test/QA plan and reports
       •  Notify the Battelle TTEP Manager to issue a stop work order if an external audit
          indicates that data quality is being compromised
       •  Coordinate the submission  of evaluation reports for final EPA approval.

       Ms. Eletha Brady-Roberts, the  NHSRC QA Manager for this program will:
       •  Review the draft test/QA plan and approve the final version
       •  Perform, at her option, one external TSA during the technology evaluation
       •  Notify the EPA TOPO to issue a stop work order if an external audit indicates that
          data  quality is being compromised
       •  Prepare and distribute an assessment report summarizing the results of the external
          audit, if one is performed
       •  Review the draft evaluation reports.

A4.4   Test Facility
       The experimental work involved in this evaluation will be performed by Idaho National
Laboratory. Over the past several years the U.S. Department of Defense (DOD) Defense
Advanced Research Projects Agency (DARPA) and the U.S. Department of Homeland Security
have been engaged in a Radionuclide Detection and Decontamination program which included a
Radionuclide  Capture and Decontamination component and Wide-Area Radionuclide Detection
component1.  Under that program, INL developed and implemented an effective method by
which five decontamination technologies for concrete surfaces were evaluated.  Because of their
experience with that previous work, INL was selected to perform the upcoming TTEP evaluation
of concrete decontamination technologies by employing similar methodology. In performing
this evaluation, Idaho National Laboratory will follow the procedures specified in this test/QA
plan and will  comply with quality requirements in the TTEP Quality Management Plan (QMP)2.
In general, the responsibilities of the technical staff of INL will be to:
       •  Ensure that any necessary laboratory equipment and hood(s) are fully functional and
          available prior to the times/dates needed in the technology evaluation.
       •  Have the appropriate training and experience to adequately complete the evaluation
          according to this test/QA plan.

-------
                                      Radiological Decontamination Processes Test/QA Plan
                                                                       Date: 9/10/07
                                                                       Version: 1.0
                                                                       Page 11 of 33

Review, approve, and maintain all data and records related to facility operation.
Adhere to the requirements of the test/QA plan and the program QMP1 in carrying out
the technology evaluation.
Provide input on facility procedures for the evaluation report.
Support Dr. James in responding to any issues related to facility operations raised in
QA assessment reports and audits.

-------
                                              Radiological Decontamination Processes Test/QA Plan
                                                                              Date: 9/10/07
                                                                              Version:  1.0
                                                                              Page 12 of 33
A5    BACKGROUND
       The National Response Plan, Nuclear/Radiological Annex, published in December of
2004, designates EPA as the lead agency for long term recovery following terrorist incidents
involving radioactive materials.  Consistent with EPA's legislated mission, this directive gives
the EPA the primary governmental responsibility for protecting human health and the
environment releases of radiological materials.  To meet the expected technology needs
associated with acts of radiological terrorism, the EPA's Office of Research and Development
(ORD), NHSRC, is conducting decontamination technology evaluations through the TTEP.
These technology evaluations will provide data to be used in support of decisions concerning the
selection and use of decontamination technologies for large outdoor environments contaminated
with radiological threat agents. The technology evaluation data may also be used in  clean-up
guidance pertaining to specific threat agents and release scenarios. This test/QA plan details the
experimental plan for the evaluation of selected commercially available radiological
decontamination technologies and/or processes that are applicable to urban building  materials,
specifically, concrete, contaminated as would be the case following terrorist use of a radiological
dispersion device (RDD), sometimes known as a "dirty bomb".

A6    TECHNOLOGY EVALUATION DESCRIPTION AND SCHEDULE
A6.1   Decontamination Technologies
       The experimental approach and evaluation matrix described within this test/QA plan is
not exclusive to one particular type of radiological decontamination technology, but  one that
would be appropriate for a variety of decontamination technologies.  The exact technologies to
be evaluated during this test have not yet been determined. However, EPA intends to test both
"chemical" (e.g., wet application, radionuclide dissolution, and removal) and "physical" (e.g.,
physical removal of contamination from the concrete surface with minimal damage)
technologies.

A6.2   Scope of Evaluation
       This technology evaluation will include concrete coupon selection, contaminant
application, radiation measurement of contamination present on coupons (by laboratory gamma

-------
                                               Radiological Decontamination Processes Test/QA Plan
                                                                              Date: 9/10/07
                                                                               Version: 1.0
                                                                              Page 13 of 33
counting), application of the decontamination technologies, and then subsequent measurement of
residual contamination in order to determine the decontamination factor (i.e., efficiency of
radionuclide removal; defined in Section B 1.6) attained by each technology. Following the
technology evaluation, reports describing the quantitative (i.e., decontamination factor) and
qualitative performance of each  technology will be generated.  The qualitative aspects, while
subjective, are a very important  part of the evaluation and will include: 1) a full description of
the technology including its mechanism of decontamination, how much ancillary equipment was
required, its applicability to other contaminants and substrates; 2) an itemization of the capital
and operating costs incurred during use of these technology including, reagents or media, waste
disposal, decontamination of equipment; 3) deployment and operational data including rate of
surface area decontamination, applicability to irregular surfaces, skilled labor requirement,
utilities requirements, extent of portability, set-up/tear-down time, shelf life of media, the
reliability of equipment; 4) secondary waste management including the estimated amount and
characteristics of the spent media; and 5) any health, safety, or legal concerns over any aspect of
the use of a technology.

A6.3   Schedule
       The initial TTEP evaluation of the decontamination technologies will be conducted
during the fall of 2007. The bulk of this experimental work will likely be completed from
October through December with the evaluation reports being drafted and peer reviewed from
approximately December through February.

A7    QUALITY OBJECTIVES
       The outcome of this evaluation is based largely on the measurement of gamma radiation
from the surface of concrete coupons. Accuracy of the detectors will be ensured through routine
calibration and duplicate sample analyses. In addition, for each sample, gamma ray counting
will be continued until the activity level of Cs-137 on the surface has a relative standard
deviation of less than 2% based  on nuclear counting statistics.  The final activity assigned to that
coupon is a compilation of information obtained from all components of the electronic
assemblage which comprises the "gamma counter", including the raw data, and the spectral

-------
                                               Radiological Decontamination Processes Test/QA Plan
                                                                              Date: 9/10/07
                                                                               Version: 1.0
                                                                              Page 14 of 33
analysis conducted by the spectroscopist using an INL data analysis program.  Final spectra and
all data which comprise the spectra are sent to a data analyst who independently confirms the
"activity" number arrived at by the spectroscopist. When both the spectroscopist and an expert
data analyst independently arrive at the same number in agreement then the data are certified.
This would be described as the full gamma counting QA process for certified results.
       In addition, the same coupons will be counted before and after application of the
decontamination technology in order to determine the decontamination factors of the
technologies. The concrete (prepared in a single batch) will have been verified that it falls within
the American Society for Testing and Materials (ASTM C150) standards for Type II Portland
cement3.

A8    SPECIAL TRAINING/CERTIFICATION
       Documentation on training related to standard radiochemistry laboratory techniques and
methods is maintained for INL technical staff in training files.  The RTL from INL will verify
the presence of appropriate training records prior to the start of testing.  All technical staff will
have a minimum of a bachelor's degree in science/engineering or have equivalent work
experience. Prior to the formal evaluation of radiological decontamination technologies, any
vendors that volunteer their technologies will have the option of training INL technicians on the
operation of their technologies. This can be done during a teleconference or during an in person
training session.  Following the training, the vendors will sign a consent form that states that they
have trained the technicians and will accept the data generated by these trained operators or
designee.

A9    DOCUMENTATION AND RECORDS
       The records for this evaluation include the test/QA plan, laboratory record books (LRB),
electronic files (both raw data and spreadsheets), audit reports, and evaluation reports. The
LRBs will serve as the primary repository of information during the experimental work
conducted during this evaluation.  The LRBs will be stored in the laboratory and periodically
reviewed by the RTL or the TOL. Following the evaluation, all evaluation records will be
transferred to permanent storage at Battelle's or INL's Records Management Office except for

-------
                                                Radiological Decontamination Processes Test/QA Plan
                                                                                Date: 9/10/07
                                                                                 Version:  1.0
                                                                                Page 15 of 33
quality assurance records which will be maintained by the Battelle Quality Assurance Manager.
All LRBs will be stored indefinitely, either by the RTL, TOL, or INL's Records Management
Office and final location will be noted in the evaluation records.  EPA will be notified before
disposal of any files.  Section BIO further details the data recording practices and
responsibilities.

-------
                                              Radiological Decontamination Processes Test/QA Plan
                                                                             Date: 9/10/07
                                                                              Version: 1.0
                                                                             Page 16 of 33
                                      SECTION B
                     MEASUREMENT AND DATA ACQUISITION
Bl     EXPERIMENTAL PLAN AND TEST SAMPLES
Bl.l   Concrete Test Coupons
       INL will supply up to 200 coupons composed of structural concrete. The coupons will be
approximately 4 centimeters (cm) thick, 15 cm square, and have a surface finish that is consistent
across all the coupons and, most importantly, that is representative of that which would be
typically found on the exterior of an urban structure (Type II Portland cement). These coupons
(2,500 of them are available) were prepared for the DARPA/DHS study1 in a single batch of
concrete provided by a redi-mix concrete supplier according to Uniform Building Code
requirements for structural concrete4.  Specifically, the redi-mix was poured into 0.9 m square
plywood forms with the surface exposed, the surface "floated" to get the smaller aggregate and
cement paste to float to the top, and then cured for 21 days. Following curing, the squares were
cut to the desired size with a laser guided rock saw. For this evaluation, the "floated" surface
will be used because of the possibility of interferences due to release agents, in the case of metal
forms, and cellulose residual, in the case of wood forms.
       The concrete has certification papers that details cementwater ratio, percent air
entrainment, admixtures, the ratio of tricalcium silicate and dicalcium aluminate, etc. Because
all of the coupons will have  been made from the same batch, tensile strength testing to confirm
uniformity within batches will not be performed. However, for the DARPA/DHS work1
mentioned previously, INL completed a comparison  of the radionuclide absorption properties of
this concrete with concrete samples collected from several locations around the United States5.
This comparison showed that the concrete coupons to be used for this evaluation are indeed
"typical" in terms of how radionuclides interact with the surfaces.
       Prior to contaminant application, the surface of the coupons will be examined for obvious
cracks or abnormalities and, if none are found, they will be cleaned with a soft nylon brush and
nanopure water and allowed to air dry for at least five days. Each coupon will be marked with an
identifying number using a permanent marker, as shown in Figure 2. In addition, in order to
protect against the possibility of any contamination seeping into the coupons through the edges,
and ensuring that contaminant is applied only via the surface of the coupons, the edges will be

-------
                                              Radiological Decontamination Processes Test/QA Plan
                                                                             Date: 9/10/07
                                                                              Version: 1.0
                                                                             Page 17 of 33
sealed with epoxy.  In addition, EPA has recommended that the concrete coupons need to be
preconditioned at 23.9 °C ± 1.7°C and between 40%-60% relative humidity (RH). However,
during the DARPA/DHS work1, INL completed a comparison of the radionuclide absorption
properties as a function of preconditioning moisture level on the surface of the coupons.  They
showed that the difference in cesium absorption depth between coupons preconditioned in an
environment of 12% RH and those saturated with water was on the order of nanometers.  This
difference corresponded to a very small difference in decontamination efficiency. INL
determined that uncontrollable differences in surface characteristics of the coupons proved to
have a more significant impact. In addition, ambient temperatures within the INL laboratories
are typically within the above range. Therefore, while the temperature and RH will not be
controlled, those parameters will be measured in the coupon storage location. However, if new
findings show that RH plays a significant role in cesium absorption, we will obtain an
environmental chamber for controlled pre-conditioning.
               Figure 2. Example Cement Coupon with Identification Marking

B1.2   Contaminant Application
       Each contaminated coupon will be spiked with 250 microliters of unbuffered, slightly
acidic aqueous solution containing 137 ppm Cs-137 which corresponds to an activity level of of
approximately 53 microCuries. The liquid spike will be delivered to each coupon using an
aerosolization technique used for the DARPA/DHS RDD program1. The aerosol delivery device

-------
                                               Radiological Decontamination Processes Test/QA Plan
                                                                              Date: 9/10/07
                                                                               Version: 1.0
                                                                              Page 18 of 33
is constructed of two syringes and is shown in Figure 3.  The first syringe has had the plunger
removed from it and a nitrogen gas line has been attached to the rear of the syringe. The second
syringe contains the contaminant spiking solution and is equipped with a 27 gauge needle which
penetrates through the plastic housing near the tip of the first syringe. Nitrogen gas is turned on
at a flow of approximately 1-2 liters per minute creating a turbulent flow through the first
syringe.  The liquid spike in the second syringe is introduced and becomes nebulized by the
turbulent gas flow. A very fine aerosol is ejected from the tip of the first syringe creating a
controlled and uniform spray of fine liquid droplets onto the coupon surface. The contaminant
spray is applied all the way to the edges of the coupon which are taped (after having previously
been sealed with epoxy) to insure that the contaminant is only applied to the surfaces of the
coupons.
       Due to the heterogenous nature of the texture of concrete coupons, perfect homogeneous
distribution of contaminant will likely never be attained. However, a reasonably uniform
coverage is expected because as the contaminant is being applied, the technician can  observe
whether or not the mist has been applied uniformly across the entire surface of the coupon.  In
addition, the intrinsic germanium detector that is used to measure the gamma rays from the
surface of these coupons has been set up specifically to measure the activity from the entire
surface of the concrete coupons.  Therefore, small differences in coverage across the  coupons,
while not quantified, will not impact the results. To protect against an  extremely rare instance
occurred in which the contaminant was applied in a very heterogeneous fashion (i.e.,  most or all
of the contaminant deposited onto one quadrant or one half of the coupon) a semi-quantitative
gamma counter will be used to confirm a reasonably uniform distribution of activity across the
surface of the coupons.  If this measurement suggests an uneven distribution of contaminant, that
coupon will not be used.  Because this is a  semi-quantitative measurement tool, this will rely on
the technician's experience of evaluating if there are areas of the coupons exhibiting abnormally
low or high levels of activity compared with the rest of the coupon. In summary, the
contaminant application step requires a degree of skill that only comes with much experience in
performing this task. Therefore, while difficuly to measure quantitatively, the technician that has
this skill is in the position to determine if a non-homogeneous application has occurred.

-------
                                              Radiological Decontamination Processes Test/QA Plan
                                                                              Date: 9/10/07
                                                                              Version: 1.0
                                                                              Page 19 of 33
       Because the activity from each full coupon will be measured before and after application
of the decontamination technology, differences in contaminant load between coupons is also not
critical. However, the acceptable amount of variation in activity on each coupon is 10%.  If a
coupon varies from the target activity level by more than 10%, it will not be used. Before
coupons are spiked, the coupon edges will be covered with masking tape to prevent accidental
overspray from contaminating the epoxy coating on the edges. The target activity level on each
coupon will be 53 microCuries Cs-137.
                                                                 Nitrogen
              Figure 3.  Diagram of the Aerosol Delivery System
B1.3   Contaminant Measurement
       Each spiked coupon will be allowed to air dry for at least 2 hours, then will be removed
from the radiological buffer area and gamma counted.  Gamma ray counting will be continued
until the average activity level of Cs-137 from the surface stabilizes to a relative standard
deviation of less than 2%.  Gamma-ray spectra acquired from Cs-137 spiked coupons will be
analyzed using the INL Radiological Measurement Laboratory  (RML) data acquisition and
spectral analysis programs. Radionuclide activities on coupons are calculated based on the
efficiency, emission probability, and half-life values. Decay corrections are made based  on
reference time and date and the duration of the counting period. Full RML gamma counting

-------
                                               Radiological Decontamination Processes Test/QA Plan
                                                                              Date: 9/10/07
                                                                               Version: 1.0
                                                                              Page 20 of 3 3
QA/QC (as described in Section A7)will be employed and certified results will be sent via inter-
department letter to the RTL.  Counting equipment is shown in Figure 2 below. This is not a
destructive measurement technique so the coupons that have been spiked with contaminant and
measured will be aged for either 7 or 28 days before they will be positioned in a radioactive hood
for application of a decontamination technology. Following application of the decontamination
technology, the residual radioactive contamination on the same coupons will be measured again
in order to calculate the decontamination factor.
                 Figure 4.  Gamma Counting Equipment at the INL RML

B1.4   Construction of the Test Stand
       In order to test these technologies in a way that simulates how they would be used in a
real-world setting, a test stand will be constructed to hold the concrete coupons in a vertical
orientation.  This stand, depicted as a schematic in Figure 5, will be constructed from a face plate
made from a non-reactive material such as Lexan. Non-reactive metal brackets extending across
the width of the face plate will be spaced adequately apart so that the concrete coupons can be
slid into these brackets from both sides and held firmly.  The stand itself will be wide enough so
that up to six concrete coupons will fit into each level  of the stand at once.  In all, this stand will
provide an area of up to six square feet of concrete surface (24 concrete coupons) to apply the
decontamination technologies. This surface area of 24 coupons will be constructed four times

-------
                                               Radiological Decontamination Processes Test/QA Plan
                                                                               Date: 9/10/07
                                                                               Version: 1.0
                                                                               Page 21 of 33
(using different coupons each time) in a vertical orientation, once after 7 days and once after 28
days for both technology types. The stand will be constructed in such a way to fit within the
radiological buffer area hood.  Throughout the construction of the test stand, INL, EPA, and
Battelle will consider the effectiveness of the stand for attaining the objective of this evaluation.
It is possible that another design will be implemented. Changes in  stand design will be
documented by amendment of the test/QA plan once the final design is determined.

^=

	





| Metal brackets


1





















| x
Six I5cmx 15cm «
coupons positioned
next to one another

f
1'
r
t

Figure 5. Schematic Diagram of Front and Side View of Test Stand Face
B1.5   Application of Decontamination Technologies
       Throughout the course of this evaluation, two decontamination technologies will be
applied to 24 concrete coupons arranged in 2' x 3' rectangular surfaces (referred to as the test
surface). Each test surface that is constructed will only be used for evaluation of one
decontamination technology. For each technology,  separate test surfaces will be evaluated in a
vertical orientation and a horizontal orientation.  In addition, separate vertical surfaces will be
evaluated 7 + 2 days after the contaminant was applied to the coupons and 28 + 2 days after it
was applied.  The same goes for the horizontal surfaces. Of the 24 coupons that are used for

-------
                                               Radiological Decontamination Processes Test/QA Plan
                                                                              Date: 9/10/07
                                                                               Version:  1.0
                                                                              Page 22 of 3 3
each test surface, six coupons, placed at edge and middle locations across the test surfaces, will
have been contaminated with radionuclide at the contaminant application step (it would be
impractical to apply contaminant to and measure all 24 coupons for each testing scenario).
Therefore, 18 coupons in each of those configurations will not have been contaminated at all,
their presence is to provide a scenario (of a wall or floor) that is similar to what might be the case
in an actual decontamination event.  Therefore, the decontamination efficiency of each
technology under each set of conditions will be measured at least six times.  Simply stated, each
test surface will be built in part with six coupons of a known activity, and following the
application of a decontamination technology, the remaining activity on those six coupons will be
measured, from which the decontamination factor can be calculated. Table 1 summarizes the
matrix of replicate test coupons in the various orientations and time delays.
       The decontamination technologies will be applied to the coupons as per manufacturer's
specifications.  All tests will either be conducted in a radiological fume hood or in a glove box
similar to those shown in Figures 6 and 7. One coupon that has not been contaminated will be
measured for background (BG) activity with each set of conditions.  The background coupons
will not be exposed to the decontamination technologies being evaluated.
     Table 1. Replicate Concrete Test Coupons for Each Decontamination Technology

7 Day
7 Day BG
28 Day
28 Day BG
Horizontal
Contamination
Measurement
6
1
6
1
Horizontal
Decontamination
Measurement
6
1
6
1
Vertical
Contamination
Measurement
6
1
6
1
Vertical
Decontamination
Measurement
6
1
6
1
   BG=Background activity measurement

-------
                                              Radiological Decontamination Processes Test/QA Plan
                                                                              Date: 9/10/07
                                                                              Version: 1.0
                                                                              Page 23 of 3 3
Figure 6. Radiological Control Hood
Figure 7.  Glovebox
B1.6   Calculation of Decontamination Efficacy
       The efficacy of decontamination will be calculated for each contaminated coupon in
order to evaluate the performance of each decontamination technology.  The decontamination
efficacy will be represented using the following equations for decontamination factor (DF) and
percent removal (%R):
                         DF = Ao/Af and %R = (l-Af/A0) x 100%
where A0 is the radiological activity from the surface of the coupon before application of a
decontamination procedure and Af is radiological activity from the surface of the coupon after
application of the decontamination technology.  Each of these equations represents the same data
in a slightly different way. The DF is the factor by which the contamination was removed and
the %R is the percent of contamination that was removed by the decontamination technology.
B1.7   Documentation of Operational Factors
       An important part of this evaluation will include the collection of qualitative data
pertaining to the operational aspects of each technology that is evaluated. This information will
include deployment and operational data including rate of surface area decontamination, which
will be measured simply by recording the time it takes to apply the decontamination technology.
It will also include applicability to irregular surfaces, skilled labor requirement, power and water
requirements, extent of portability, set-up/tear-down time, shelf life of media, and the reliability

-------
                                              Radiological Decontamination Processes Test/QA Plan
                                                                              Date: 9/10/07
                                                                              Version: 1.0
                                                                              Page 24 of 3 3
of equipment.  The information will be obtained by having the evaluation staff responsible for
operating the technology during the evaluation test fill out a questionnaire that includes questions
about these issues..  These staff will be INL technicians that have been trained by the vendor in
the operation of the technology. Some of the qualitative information will be easily gleaned
through their operational experience during the evaluation, but other information, such as the
applicability to irregular surfaces and the extent of portability, will require them to think  about
how effective these technologies would be if deployed for a field decontamination scenario.
       The approximate volume and weight of any secondary waste generated per unit surface
area decontaminated will be reported.  This might be reported in units of number of containers
that had to be disposed of as well as the approximate weight of those containers. The physical
characteristics of the waste will be described as well (e.g., if the waste is a solid, liquid, slurry,
etc.). The ease of clean-up and of secondary waste containment will also be described by the
operators. Lastly, the evaluation staff questionnaire  will also include be questions about  any real
or perceived health or safety concerns over any aspect of the use of the technology and
documented and reported.

B2     REFERENCE SAMPLE COLLECTION
       The radiological activity of the contaminated coupons will be measured after
contamination and then again after application of the decontamination technologies.  Because of
the direct nature  of radionuclide measurement from the surface of the coupons, no reference
samples will be collected during this evaluation.

B3     SAMPLE HANDLING AND IDENTIFICATION
       The key concern with sample handling and custody during this evaluation will be the
systematic organization of sample labeling so the concrete coupons that are contaminated and
then decontaminated remain properly identified from coupon contamination through final
gamma counting. This will be done by providing an identification number that is marked on the
edge of each concrete coupon in permanent marker and then covered with clear epoxy to ensure
its integrity. This number will be recorded in a laboratory record book and used throughout the
measurement and decontamination components of the evaluation. After contaminant application,

-------
                                              Radiological Decontamination Processes Test/QA Plan
                                                                              Date: 9/10/07
                                                                              Version: 1.0
                                                                              Page 25 of 3 3
each coupon will be stored in its own transparent plastic bag to allow visibility of the
identification number and protect against cross-contamination between coupons.

B4    ANALYTICAL METHODS
       Direct gamma counting is the only measurement method that will be used during this
evaluation. Coupons with an unknown Cs-137 activity will be placed into gamma ray counters
and nuclear counting will continue until the average activity level of Cs-137 measured on the
surface stabilizes to a relative standard deviation of less than 2% based on nuclear counting
statistics.  The sensitivity of these counters is 10 picoCuries of activity. Gamma ray counters
employ pulsered, intrinsic, High Purity germanium (HPGe) detectors which are either Low
Energy (Canberra LEGe Model GL 2825R/S) or Broad Energy (Canberra BEGe Model 2025 S)
detectors cooled with liquid nitrogen in a shielded, integral cryostat. Detectors are equipped with
an integral pre-amplifier which utilizes dynamic charge restoration methods to discharge the
integrator. High voltage is supplied to the detectors  using a Canberra Model 3125 power supply.
Signal from the detector is processed through a Canberra Model 2026 spectroscopy amplifier to
achieve correct shaping and amplitude.  Shaped signal then goes to a Canberra Model 8713
analog to digital converter (ADC) where the signal is digitized into a pulse height spectrum. A
Canberra Model 556A acquisition interface module  (AIM) is used to control the ADC, and to
collect and transfer the data over an ethernet connection to a computer. Spectral analysis is
conducted using the a software program developed at the INL.  Radionuclide activities  on the
coupons are calculated based on individual detector  efficiency, emission probability, and half-
life values. Decay corrections are made based on reference time and date and the duration of the
counting period. If specified, interference corrections between the desired photopeak and
background interference are made.  Data are also manually analyzed by an experienced  gamma
ray spectroscopist to confirm the value which the computer has determined.

B5    QUALITY CONTROL REQUIREMENTS
       Approximately 10% of the total coupons to be gamma counted will be counted two times
(with a requirement of agreement within 5%) as a quality check on the reproducibility of the
counting method.  In addition, the background activity of at least one coupon will be measured

-------
                                              Radiological Decontamination Processes Test/QA Plan
                                                                              Date: 9/10/07
                                                                              Version: 1.0
                                                                              Page 26 of 3 3
for each set of test conditions (technology, orientation, aging time, etc.). See Section A7 for a
description of the quality assurance of the certified activity levels.
B6    INSTRUMENT/EQUIPMENT TESTING, INSPECTION, AND MAINTENANCE
       The key piece of equipment is the intrinsic high purity germanium detector. It and the
accompanying electronics which comprise the "gamma counter" will be maintained according to
INL standard procedures.  Other equipment and supplies may include adjustable volume pipettes,
beakers, etc.  In general, all equipment will be operated and maintained per manufacturer
recommendations, or existing facility requirements.

B7    INSTRUMENT CALIBRATION AND FREQUENCY
       The intrinsic, high purity germanium detector energy  calibrations will be established
using standardized techniques called out in American National Standards Institute(ANSI)/
Institute of Electrical and Electronics Engineers (IEEE) 325-1996, 1996. IEEE Standard Test
Procedures for Germanium Gamma-ray Detectors6, and ANSI N42.14-1999, 1999. Calibration
and Use of Germanium Spectrometers for the Measurement of Gamma-ray Emission Rates of
Radionuclides, ANSI7.  In brief, detector energy calibrations will be established using thorium-
228 daughter gamma rays at 238.6, 583.2, 860.5, 1620.7, and 2614.5 kilo electron volts. A
quadratic fit of the energy of each photopeak versus detector  channel will be done with an
estimated uncertainty of + 0.03 keV over the given range. Detector efficiency calibrations will
be accomplished using the Cs-137 photopeak at 661.6 keV. Detector efficiency at 661.6 keV
will be determined both as a function of detector height from the surface of the coupon and as a
function of known Cs-137 activity on the surface. Efficiency  calibration curves will be
established to an estimated uncertainty of + 2.0% at the 68.3% confidence  level (1 sigma).  This
rigorous calibration  is performed weekly and documented by the RML and in addition, weekly
calibration checks are performed using a europium-152 standard. These calibration checks
provide assurance that the detectors are functioning properly. All calibrations or calibration
checks will be documented in the project laboratory record book. The instrument records will  be
reviewed by the Battelle QA Manager or designee prior to the evaluation.

-------
                                               Radiological Decontamination Processes Test/QA Plan
                                                                              Date: 9/10/07
                                                                               Version:  1.0
                                                                              Page 27 of 3 3
B8    INSPECTION/ACCEPTANCE OF SUPPLIES AND CONSUMABLES
       All materials, supplies, and consumables to be used during the evaluation will be ordered
by the RTL or designee. Battelle and INL will rely on previous experience or recommendations
to guide selection of manufacturers and materials. The ingredients of the concrete used to
prepare the coupons will be reviewed to confirm that it meets the criterion for structural concrete.
The Ready-mix supplier will provide documentation to INL that the concrete used in the coupons
meets the ASTM standards for Type II Portland cement.

B9    NON-DIRECT MEASUREMENTS
       Data published previously in the scientific literature will not be used during this
evaluation.

BIO    DATA MANAGEMENT
       Data will be acquired and recorded electronically or manually by Battelle or INL
technical staff during this evaluation test. All data and observations for the operation of the
radiological decontamination technologies will be documented by Battelle technical staff in
laboratory record books. All hand written entries will be recorded in  ink and corrections to the
entry will be made with a single line so as to not obliterate the original entry. The correction will
be initialed and dated. An explanation will accompany all non-obvious corrections.  Records
received by or generated by any of the technical staff during the evaluation will be reviewed by a
Battelle or INL staff member within two weeks of receipt or generation, respectively, before the
records are used to calculate, evaluate, or report evaluation results. If a staff member generated
the record, this review will be performed by a technical staff member involved in the evaluation
test, but not the staff member that originally received or generated the record. The review will
be documented by the person performing the review by adding his/her initials and date to the
hard copy of the record being reviewed. In addition, data calculations performed by technical
staff will be spot-checked by other staff to ensure that calculations are performed correctly.
Calculations to be checked include any statistical calculations described in this test/QA plan.
The data  obtained from this evaluation will be compiled for each radiological decontamination

-------
                                               Radiological Decontamination Processes Test/QA Plan
                                                                               Date: 9/10/07
                                                                                Version: 1.0
                                                                               Page 28 of 3 3
technology. During the course of any assessment or audit, the Battelle QA Manager or designee
will inform the technical staff of any immediate corrective action that should be taken.  If serious
quality problems exist, the Battelle QA Manager, or designee, will contact the TTEP Manager,
who is authorized to stop work. Once the assessment report has been prepared, the TOL will
ensure that a response is provided for each adverse finding or potential problem, and will
implement any necessary follow-up corrective action.  The Battelle QA Manager will ensure that
follow-up corrective action has been taken.

-------
                                              Radiological Decontamination Processes Test/QA Plan
                                                                              Date: 9/10/07
                                                                              Version: 1.0
                                                                              Page 29 of 3 3
                                      SECTION C
                           ASSESSMENT AND OVERSIGHT
Cl    ASSESSMENTS AND RESPONSE ACTIONS
       Every effort will be made in this evaluation test to anticipate and resolve potential
problems before the quality of performance is compromised.  One of the major objectives of the
test/QA plan is to establish mechanisms necessary to ensure this. Internal quality control
measures described in this test/QA plan, implemented by the technical staff and monitored by the
TOL, will give information on data quality on a day-to-day basis. The responsibility for
interpreting the results of these checks and resolving any potential problems resides with the
TOL. The technical staff has the responsibility to identify problems that could affect data quality
or the ability to use the  data.  Any problems that are  identified will be reported to the TOL, who
will work with the Battelle QA Manager to resolve any issues. Action will be taken to control
the problem, identify a  solution to the problem, and minimize losses and correct data, where
possible. Independent of EPA QA activities, Battelle will be responsible for ensuring that the
following audits are conducted as part of this evaluation test.

Cl.l   Technical Systems Audits
       The Battelle QA Manager, or designee at INL, will perform a technical systems audit
(TSA) at least once during this evaluation test.  The purpose of this audit is to ensure that the
evaluation is being performed in accordance with the QMP1 and this test/QA plan. In this audit,
the Battelle QA Manager, or  designee, may review the gamma counting methods used, compare
actual test procedures to those specified or referenced in this plan, and review data acquisition
and handling procedures. A TSA report will be prepared, including a statement of findings and
the actions taken to address any adverse findings. The NHSRC QA Manager will receive a copy
of Battelle's TSA report. At  EPA's discretion, EPA QA  staff may also conduct an independent
on-site TSA during the  evaluation. The TSA findings will be communicated to technical staff at
the time of the audit and documented in a TSA report.

-------
                                              Radiological Decontamination Processes Test/QA Plan
                                                                              Date: 9/10/07
                                                                              Version: 1.0
                                                                              Page 30 of 33
C1.2   Data Quality Audits
       The Battelle QA Manager will be responsible for auditing at least 10% of the evaluation
data acquired in the evaluation test. The Battelle QA Manager will trace the data from initial
acquisition, through reduction and statistical comparisons, to final reporting. All calculations
performed on the data undergoing the audit will be checked.

C1.3   QA/QC Reporting
       Each assessment and audit will be documented in accordance with Section 3.3.4 and
3.3.5 of the QMP1. The results of the assessment reports will be submitted to EPA. Assessment
reports will include the following:
    •   Identification  of any adverse findings or potential problems
    •   Response to adverse findings or potential problems
    •   Recommendations for resolving problem
    •   Confirmation  that solutions have been implemented and are effective
    •   Citation of any noteworthy practices that may be of use to others

C2    REPORTS TO MANAGEMENT
       The Battelle QA Manager, or INL designee, during the course of any assessment or audit,
will identify to the technical staff performing experimental activities any immediate corrective
action that should be  taken. If serious quality problems exist, the Battelle QA Manager,  or INL
designee, will contact the Battelle TTEP Manager who is authorized to stop work. In such an
event, the RTL and TOL would work together to quickly resolve whatever issues exist and
document any corrective actions. Once the assessment report has been prepared, the TOL will
ensure that a response is provided for each adverse finding or potential problem and will
implement any necessary follow-up corrective action. The Battelle QA Manager will ensure that
follow-up corrective action has been taken. The test/QA plan and final report are reviewed by
EPA QA staff and EPA program management staff.

-------
                                              Radiological Decontamination Processes Test/QA Plan
                                                                              Date: 9/10/07
                                                                              Version:  1.0
                                                                              Page 31 of 33
                                      SECTION D
                        DATA VALIDATION AND USABILITY
Dl    DATA REVIEW, VALIDATION, AND EVALUATION REQUIREMENTS
       The key data review requirements include a comparison of laboratory record book data
and comments against final data to flag any suspect data and a review of final data to resolve any
questions about apparent outliers. The quality assessments, as described within Section C of this
document are designed to assure the quality of this data.

D2    VALIDATION METHODS
       Data validation is conducted as part of the data review in Section Dl of this test/QA plan.
This validation will include a visual inspection of hand written data to ensure that all entries were
properly recorded and that any erroneous entries were properly noted. Calculations used to
determine Cs-137 concentrations will be spot checked to ensure accuracy and the
appropriateness of the calculations.  Data validation efforts include the completion of QC
activities and the performance of a ISA as described in Section C.I.2. An audit of data quality
will be conducted by the Battelle QA Manager to ensure that data review and validation
procedures were completed, and to assure the overall quality of the data.

D3    RECONCILIATION WITH USER REQUIREMENTS
       The purpose of this test is to evaluate the performance of radiological decontamination
technologies. The data obtained shall include thorough documentation of the performance of
each technology.  The data review and validation procedures described in the previous sections
will assure that data meet these requirements and are accurately presented in the evaluation
reports generated from this test.  Any limitation to the data will be discussed in the report.
       The data generated in this evaluation will be compiled into one TTEP evaluation report
for each technology evaluated. The report will be submitted to EPA in Word and Adobe pdf
format and subsequently posted on the TTEP website.  This test/QA plan and the resulting TTEP
evaluation report(s) will be subjected to review by the radiological decontamination technology
vendors, Battelle and INL staff, EPA,  and expert peer reviewers.  The reviews of this test/QA

-------
                                                   Radiological Decontamination Processes Test/QA Plan
                                                                                     Date: 9/10/07
                                                                                     Version:  1.0
                                                                                     Page 32 of 33

plan will assure that this evaluation and the resulting reports meet the needs of potential users of

the evaluated technologies.

-------
                                         Radiological Decontamination Processes Test/QA Plan
                                                                        Date: 9/10/07
                                                                        Version: 1.0
                                                                        Page 33 of 33
                                 SECTION E
                                REFERENCES
1.  Radionuclide Detection and Decontamination Program, Broad Agency Announcement
   03-013, U.S. Department of Defense (DOD) Defense Advanced Research Projects
   Agency (DARPA) and the U.S. Department of Homeland Security, classified program.
2.  Quality Management Plan for the Technology Testing and Evaluation Program, Version
   2.0, Battelle, Columbus, Ohio, January 2006.
3.  ASTM Standard C 150-07, 2007, "Standard Specification for Portland Cement," ASTM
   International, West Conshohocken, PA, www.astm.org.
4.  ACT Manual of Concrete Practice, American Concrete Institute, October 1978.
5.  Adsorption of cesium and cobalt onto cement, granite, and marble, Fox, R. V.; Ball, R.
   D.; Houghton, T.P.; and Fox S. L., poster -62nd Annual Meeting of the Northwest
   Regional American Chemical Society, June 2007.
6.  Standard Test Procedures for Germanium Gamma-ray Detectors ANSI/IEEE Std. 325-
   1996, Issue 29, May 1997.1996.
7.  Calibration and Use of Germanium Spectrometers for the Measurement of Gamma-ray
   Emission Rates of Radionuclides, American National Standards Institute ANSI N42.14-
   1999. New York, IEEE 1999 (Rev. 2004).

-------
                                                                      EPA/600/R-08/132 I November 2008 I www.epa.gov/ord
$EPA
     United States
     Environmental Protection
     Agency
PRESORTED STANDARD
 POSTAGES FEES PAID
         EPA
   PERMIT NO. G-35
     Office of Research and Development
     National Homeland Security Research Center
     Cincinnati, OH 45268

     Official Business
     Penalty for Private Use
     $300
             Recycled/Recyclable
             Printed with vegetable-based ink on
             paper that contains a minimum of
             50% post-consumer fiber content
             processed chlorine free

-------