               Large-Volume Sample Preparation
               for Waterborne Pathogens

               Workshop Summary Report
   Office of Water
   Office of Research and Development. Cincinnati OH 45268

-------
Large-Volume Sample Preparation for Waterborne
     Pathogens Workshop Summary Report
                      Edited by

            Sandhya Parshionikar, Office of Water
      Ann C. Grimm, National Exposure Research Laboratory

-------
                                        Notices
The views expressed in this Summary Report are those of the individual authors and may not necessarily
reflect the views and policies of the United States Environmental Protection Agency (EPA). Mention of
trade names or commercial products does not constitute endorsement or recommendation by EPA for
use.

-------
            Large-Volume Sample Preparation for
   Waterborne Pathogens Workshop Summary Report

                 U.S. Environmental Protection Agency
Andrew W. Breidenbach Environmental Research Center, Cincinnati, OH

                          April 4 and 5, 2006

                          SPEAKER LIST
           Kevin Oshima, U.S. Environmental Protection Agency
      "Characterization and Optimization of Ultrafiltration Processes for the
                 Efficient Recovery of Waterborne Pathogens"

        Vincent Hill, U.S. Centers for Disease Control and Prevention
        "Ultrafiltration for Simultaneous Recovery of Diverse Biological
                        Agents in Drinking Water"

               Otto D. Simmons, University of North Carolina
        "Improved Methods for Concentrating Microbial Pathogens from
                        Large Volumes of Water"

         Jennifer Cashdollar, U.S. Environmental Protection Agency
 "Reuse of Electropositive Cartridge Filters for Concentrating Viruses from Water"

          Mark Borchardt,  Marshfield Clinic Research Foundation
  "Concentration of Enteroviruses, Adenoviruses, and Noroviruses from Drinking
                      Water with Glass Wool Filters"

                    Fred Tepper, Argonide Corporation
                 "High-Volume Sampling and  Concentration"

                   Fu-Chih Hsu, Scientific Methods, Inc.
     "Concentration of Viruses from Water Using Functionalized Silica Beads"

                    Jim Larkin, Scientific Methods, Inc.
       "Continuous-Flow Centrifugation of Pathogens and Indicators from
                      Large-Volume Water Samples"

           Suresh D. Pillai  and AM Beskok, Texas  A&M University
    "A Microfluidic Approach to Capturing and Concentrating Organisms from
                         Large Sample Volumes"

                  Mike Kent, Sandia National Laboratory
    "A High-Volume Alternative to Filtration Based on Adsorption and Elution"

                Blake Simmons, Sandia National Laboratory
    "Design, Fabrication, and Testing of Polymeric Microfluidic Separators and
           Concentrators Utilizing Insulator-Based Dielectrophoresis"

                 Mike Carpenter, Idaho National Laboratory
                   "Making a Lab Process Field Portable"

-------
                   Large-Volume Sample Preparation for
           Waterborne Pathogens Workshop Summary Report

At the U.S. Environmental Protection Agency's (EPA) workshop entitled "Large-Volume
Sample Preparation for Waterborne Pathogens," leading scientists from across the country
gathered in Cincinnati, Ohio, on April 4 and 5, 2006, to discuss a wide variety of techniques for
capturing and concentrating waterborne pathogens. Experts gave 12 presentations on a range of
topics, including various filtration methods, continuous flow centrifugation, microfluidic devices
that use electrophoresis or dielectrophoresis, and field-portable water concentrators.


Welcome and Workshop Objectives

Opening
Eric Bissonette, EPA

The conference began with an opening statement from Mr. Eric Bissonette, Deputy Director of
the Technical Support Center of the Office of Ground Water and Drinking Water (OGWDW), in
which he welcomed the workshop participants.

Workshop Background and Objectives—ORD's Perspective
Ann Grimm, EPA

Dr. Ann Grimm, Chief of the Biohazard Assessment Research Branch of the National Exposure
Research Laboratory  (NERL), explained the need for the workshop. Specifically, occurrence
methods are critical to EPA because they allow the Agency to obtain information on the presence
and concentration of waterborne pathogens. Such information is needed to determine the risk
associated with these contaminants. In addition, these methods are important for determining the
effectiveness of treatment methods.
Over the past several  years, there have been dramatic improvements in the quality of detection
methods for waterborne pathogens because of significant technological advances. For instance,
there are now molecular methods that can detect waterborne pathogens in less than two hours.
However, technologies often focus only on a single class of pathogen and can be both expensive
and time consuming.  Although more research is needed in the area of pathogen detection, overall,
this component of occurrence methods is progressing rapidly. In contrast, the sample collection
part of these methods has lagged behind. Although significant progress has recently been made
in the technologies used for sample collection and concentration, much still needs to be done to
incorporate these improvements into complete pathogen detection methods. EPA, therefore, is
considering where it should invest its funding and research efforts in this area. Ultimately, the
goal is to develop a method that can concentrate a variety of pathogens; has good recovery;  and
is rapid, relatively inexpensive, and easy to use.

-------
Workshop Background and Objectives—OW's Perspective
Sandhya Parshionikar, EPA

Dr. Sandhya Parshionikar of the Technical Support Center of OGWDW, elaborated on Dr.
Grimm's comments, providing further background for the workshop. The Safe Drinking Water
Act, enacted in 1974, mandates EPA to set national health-based standards for drinking water to
protect consumers from contaminants. This includes the identification of new contaminants that
may require regulation in the future. The Contaminant Candidate List (CCL) is the Agency's list
of priority unregulated chemicals and microorganisms.  This list, which includes several
pathogens, is used to prioritize research and data collection efforts to determine if specific
contaminants will need to be regulated. Data collection, which includes gathering  accurate
information on occurrence, disinfection properties, health effects, and dose response, requires
robust detection methods for the pathogen of concern. Also, although alternate approaches exist,
such as the use of indicators, they can be limited in their ability to  accurately predict the presence
of pathogens. Furthermore, other EPA-hosted workshops, held to determine the usefulness of
molecular techniques in solving environmental problems, identified the pathogen capture and
concentration methods as the bottleneck to detection. Low recovery efficiencies, high variability
in recovery efficiencies, high costs, and the inability to  simultaneously sample for all classes of
pathogens, such as viruses, bacteria, and protozoa, are some of the major challenges to water
sampling. This served as a crucial impetus for the workshop in Cincinnati. Therefore, the
workshop objectives were to:

• summarize and evaluate the state of the science,

• identify research gaps in technologies useful for EPA, and

• support research in those technologies that can be useful for EPA in the near future.

-------
Day 1: Invited Speaker Presentations
Characterization and Optimization of Ultrafiltration Processes for the
Efficient Recovery of Waterborne Pathogens
Kevin Oshima, EPA

Dr. Kevin Oshima, formerly of the Department of Biology at New Mexico State University,
described the challenges in trying to concentrate multiple pathogens from groundwater, surface
water, drinking water, sewage effluent, and other water matrices. One of these challenges is the
difficulty in obtaining consistent recoveries from water sources with differing water quality
parameters. Therefore, a goal of this research has been to try to develop a methodology or
process that can concentrate a range of contaminants including viral agents, bacterial agents,
protozoans, and toxins.
For multiorganismal recoveries, ultrafiltration and microfiltration are well-established
methodologies. There are significant differences between ultrafiltration and microfiltration; for
instance, ultrafiltration can retain even the smallest viruses, whereas microfiltration usually stops
at the ability to trap, remove, or retain bacterial agents and protozoa. Dr. Oshima's group has
focused on researching ultrafiltration, in particular, the development of a rapid, user-friendly
method.  In one study, virus recoveries between small-scale and large-scale 50,000 molecular
weight cutoff, hollow-fiber ultrafiltration systems was determined using spiked water samples.
The recoveries of virus, bacteria, and Cryptosporidium parvum using this 10-L system  were also
determined. Consistent recoveries among viral, bacterial, and protozoan agents were obtained
using this simultaneous approach.
In addition, Dr. Oshima has determined that:
• Ultrafiltration methods have been developed for multiorganism concentration from ground,
  surface, and drinking water that have greater than 50% recovery, except for Cryptosporidium
  oocysts.

• Ultrafilters can be reused at least 30 to 40 times without loss of performance.

• Pretreatment of the filters appears feasible and it can be done overnight. Once pretreated, the
  filter can either be used immediately or stored for up to one month.

• Concentrations of 100-L samples down to 15 to 20 mL can be completed in less than three
  hours.
In the future, his group plans to do additional work that includes completing final optimization of
100-L concentration procedure with low pathogen concentrations, and testing new concentration
methods with a variety of environmental water samples; not just drinking water.

-------
Ultrafiltration for Simultaneous Recovery of Diverse Biological Agents in
Drinking Water
Vincent Hill,  U.S. Centers for Disease Control and Prevention (CDC)

The CDC became interested in ultrafiltration because of its duty to respond to suspected
bioterrorism events and waterborne disease outbreaks. In particular, Dr. Hill has been interested
in finding techniques to detect biothreat agents in drinking water distribution systems.

The group's main goal has been to establish a single sampling technique for total microbe
capture. A short response time is critical, as is high recovery efficiency. In addition, the
technique needed to be field deployable and compatible with culture-, polymerase-chain-
reaction- (PCR),  and immunodiagnostic-based detection methods.
Dr. Hill described the filtration processes, provided a schematic for an ultrafiltration method, and
outlined the secondary concentration techniques his group used. Among his project's results, a
50% recovery generally was achieved using just ultrafiltration (he did not incorporate secondary
concentration data into his talk) for vegetative bacteria, bacterial spores, viruses, and parasites.
The use of polyphosphate improved the recovery of most microbes but had negative effects on
culturability for one type of bacteria (but not on vegetative bacteria in general); the group has
been using divalent cations and organic media to counteract the effect.
In his work with low seeding levels, he detected pathogens consistently at concentrations of as
low as 100 microbes per 100 L using PCR in conjunction  with sample collection.
The processing times were 1.5 to 2 hours for ultrafiltration,  1 to 2 hours for secondary
concentration,  and 2 to 2.5 hours for nucleic acid extraction and real-time PCR. Consequently,
the entire method could be completed in 4.5 to 6.5 hours, which was the group's goal for a rapid
method.
The costs totaled about $60 to $80 per sample for single-use consumables. The system could be
field deployable, making it effective for groundwater-related outbreak investigations. With this
method, his group has detected various viruses, bacteria, and parasites in contaminated
groundwater.
Improved Methods for Concentrating Microbial Pathogens from Large
Volumes of Water
Otto D. Simmons, University of North Carolina

Water quality is a significant concern because it is necessary for public health, and it is very
important for there to be consumer confidence in the public water supply. In addition, with
regard to microbial contaminants, there are societal and economic costs associated with
microbial disease outbreaks, as evidenced in the loss of worker days and higher health care costs.
For more than 100 years, the primary way of assessing the microbial quality of water has been to
look for indicator organisms. As detection methods for pathogens have improved, the question
becomes whether it is better to use direct pathogen detection methodologies. To determine the
risk posed by waterborne organisms, there are two possible approaches. One option is to be

-------
reactive, as in doing retrospective epidemiological studies or by acting in response to ecological
problems. In contrast, the second option is to take the proactive approach, which is to promote
public health by monitoring source and finished waters or by improving biosecurity in response
to potential terrorist events through the use of improved concentration, isolation, and detection
methodologies for the pathogens of greatest concern. In order to implement a proactive approach,
Dr. Simmons believed that direct pathogen detection would be necessary.
In joint research with Professors Mark Sobsey and Jan Vinje, it was determined that there were
statistically significant differences in murine norovirus recovery between the Cuno Virosorb
1MDS pleated cartridge and 90 mm flat-disk filters. Overall recovery was 2.5% for cartridge
filters and about 19% for flat filters. In these experimental trials, deionized reagent water was
comparable to tap water. These comparisons are important to characterize because the smaller
filters are less expensive and can process smaller water samples. This would be important when
there are limited volumes of suspect water, such as from a retrospective outbreak investigation. If
larger volumes of sample are available, it generally is  advantageous to process these larger
volumes, thus lowering the overall method detection limit and improving the probability of
detecting viruses in the waters sampled.
Additional work by Dr. Simmons focused on alternative eluting solutions for 1MDS filters,
specifically, ones made with arginine,  asparagine, glycine, or lysine. These alternate elutants are
advantageous because they are more defined and do not inhibit downstream virus detection
methodologies, such as molecular methods. He saw several advantages in the Cuno Virosorb
1MDS filter method for microbial concentration. For instance, for the current EPA method to
detect virus in water, no pretreatment of water is necessary prior to filtration, the filters are
capable of processing large volumes of water in short  periods of time, and there are multiple
filter formats for different types and volumes of water. However, there are numerous
disadvantages of the 1MDS filter, including the fact that they are very expensive and have
demonstrated variable recoveries with  different groups of viruses and water quality parameters.
Also, humic and fulvic acids can interfere with virus adsorption to and elution from the surface
of the filters.
Dr. Simmons has also been investigating the use of hollow-fiber ultrafiltration (HFUF) because
this method is capable of concentrating multiple classes of pathogens using a single filter, which
is inexpensive and made to the high standards of the medical industry. He also recognized these
filters limitations, which include longer sample processing times and potential downstream
problems during secondary concentration steps (they concentrate everything, including inhibitors
that may interfere with molecular detection methodologies). To address the first issue, he hoped
to develop ideas to decrease sample processing times.  As for the second issue, he hoped to
demonstrate that initial HFUF and secondary concentration steps are compatible with molecular-
and cell-culture-based detection methods.
He concluded by noting that he and Mark Sobsey were recently awarded an EPA Star Grant,
which gives them the funding to develop a new charge-modified filter during the next two years.
They will then compare the developed filter's use with the currently used Cuno Virosorb 1MDS
filter in a round-robin study with other laboratories familiar with the current method. This will
ensure that the technology can adequately be transferred and will demonstrate that the new
system works independently in other laboratories  and  with a variety of water types.

-------
Reuse of Electropositive Cartridge Filters for Concentrating Viruses from
Water
Jennifer Cashdollar, EPA

Ms. Cashdollar, who collaborated with EPA scientist Daniel Dahling on this project, identified
the need for a robust method for virus recovery from large volumes of water that would result in
high virus recovery while being cost effective and simple, so that most laboratories can perform
it. Ideally, a desirable filter method would be one in which the testing laboratory would take the
filter out to the field, hook it up, and walk away while the sample was being collected. She noted
the advantages and disadvantages of electropositive filters, such as the 1 MDS filter used by the
Agency to collect viruses. The biggest disadvantage is the cost of these filters (US $150-$ 180
each). This was one of the driving forces for investigating whether the filters could be used
numerous times. She described previous scientists' regeneration of pleated electronegative filters
and her group's attempt to adapt the method for use with electropositive cartridge filters.  As data
was being collected on filters that were treated and reused, it was noted that recovery efficiencies
were comparable between filters that were treated (with 0.1  M sodium hydroxide) and those that
were new. A new set of filters were then tested that were not treated prior to reuse to ascertain
whether treatment was even necessary.
In the study, several factors were found to be statistically significant in virus recovery: water
type (whether it was tap water or river water), filter type, and the volume of water filtered
(although it was important to note that all 20-L volumes of water were tap water, which was
statistically significant). There was no statistical difference in recovery between new filters,
filters that were treated, or filters that were untreated. In addition, filters could be used one to
three times without a statistically significant impact on percent recovery.
Concentration of Enteroviruses, Adenoviruses, and Noroviruses from
Drinking Water with Glass Wool Filters
Mark Borchardt, Marshfield Clinic Research Foundation

Dr. Mark Borchardt, his colleagues from the Marshfield Clinic, and researchers at the University
of California-Davis, have been involved in a collaborative project that makes use of a novel glass
wool filter. Dr. Borchardt noted that his group did not develop the glass wool filter method being
used in this study, although the technique was validated in his laboratory. The impetus for the
work came from a large groundwater epidemiological study called the Wisconsin Water and
Health Trial for Enteric Risk (WAHTER) Study.
The goal of the project was to estimate the amount of illness occurring in children who drank
municipal water served by a groundwater source. A secondary objective was to determine the
source of the viruses in the communities.
One of the problems faced by the study was the cost of virus sampling. Specifically, there were
14 communities involved in the study, and for each, 12 samples needed to be taken every month
for a year. Because each filter cost $170, and the university charged a 50% indirect rate, the total
filter cost would have been $514,080. In contrast, it was determined that the total cost of glass
wool filters for the project, including assembly labor plus the indirect cost, came to $25,636. He
                                          10

-------
therefore adopted the glass wool filter method for the study. To evaluate the method, his group
looked at the following variables: virus type, water matrix, pH, flow rate, virus seeding level, and
filter size. Their goal was to concentrate the EPA CCL viruses at a flow rate of 4 L per minute.
When looking at factors important for glass wool recovery, his group had to use a linear mixed-
effects model because of the day-to-day variation seen with this method. He found that flow rate
and volume filtered, among other things, did not have a statistically significant impact on
recovery. Variables that were significant for the glass wool method included virus type, water
matrix, and the interaction between these two factors. Also, the pH of the sample is crucial for
glass wool recovery, with high pH being associated with poorer recovery.
He emphasized the advantages of glass wool. The cost of the materials for one glass wool filter
can be divided into a one-time cost of $3.65, and an expendable cost of $0.75. As for the labor
for constructing glass wool filters, his estimate is 15 minutes per filter.
Dr. Borchardt concluded that the recovery efficiency of the glass wool  method ranged from 8%
to 98%, and that it depended on virus type and water matrix.  Additionally, it was determined that
the water pH must be less than 8.0 for effective concentration, and that it was possible to do
continuous-time composite sampling. In summary, glass wool filtration is a cost-effective
method for concentrating viruses from large sample volumes.
High-Volume Sampling and Concentration
Fred Tapper, Argonide Corporation

Mr. Tepper introduced attendees to another kind of filter called the NanoCeram® filter, which is
relatively inexpensive and good at concentrating viruses out of water. Argonide, founded in 1994
to develop nanotechnology products, sells NanoCeram® filters, whose active ingredient is a
highly electropositive nanoalumina (aluminum oxide hydroxide) fiber of only 2 nm in diameter.
These nanoalumina fibers are distributed on the scaffolding of another fiber, e.g., glass. The filter
media is manufactured using paper-making technology. During the several manufacturing steps,
the nanofibers are dispersed and adhere to glass fibers.
For NanoCeram® filters, flow rates (flux) were determined to be ten-fold or greater than
ultraporous membranes. Furthermore, NanoCeram® separates particles by charge rather than
size and has higher retentivity for virus than "absolute" ultraporous membrane filters or other
electropositive media. Additionally, filtration efficiency for micron-size particles exceeds
99.995%.
This filter was found to work well with matrices that contained a significant amount of
particulates. For instance, when used with water samples, the filter was able to function in a
muddy stream. In addition, the filter was very effective for removing viruses—at least at
sampling levels—and bacteria.  It operates effectively over pH 5-9.5 and in the presence of salt
water.
Right now, the company's principal thrust is the manufacture of filters as primary adsorbers
(point of use at a faucet, point of entry for a whole house, and as a prefilter to extend the life of
reverse osmosis membranes). The filters are being developed for portable (bottle) filter systems,
                                           11

-------
and the company is looking at biological warfare filters for the military, for hospitals, and for
other critical buildings.

In conclusion, the NanoCeram® filter is formulated specifically for water and can effectively
filter parasites, bacteria, and virus. Additionally, large-pore NanoCeram® filters are superior to
HEPA filters for retention of dry aerosols, as well as of microbe-containing aerosols. It has major
promise as an air sampling media. Microbes can be eluted from the media, although elution is far
less efficient than the adsorption step. Finally, a novel multistage adsorption/desorption process
for concentrating virus was described. He said that they demonstrated an enhancement factor of
2700 in one stage and a projection of 106 for two stages. A third stage may be needed to get from
100 L of sample down to microliter levels.
Note: In May 2008, Mr. Fred Tepper provided the following update on the NanoCeram® filter.
NanoCeram® VS2.5-5 virus filters have been tested in many countries and found to exceed the
performance of 1MDS sampling filters.  Three U S  groups, including the EPA, are developing
methodology for sampling of virus in fresh and sea water.  International R& D teams in Korea,
the U K,  Canada and France are utilizing existing extraction EPA-developed protocols and also
modifying them for different viruses using NanoCeram® samplers. The main benefits of the
NanoCeram unit are its much lower cost than the 1MDS, its capability to be used in alkaline
water (without requiring pH neutralization), its utility in sea water and the reduction of
complexity in extraction.
Concentration of Viruses from Water Using Functionalized
Silica Beads
Fu-Chih Hsu, Scientific Methods Incorporated

Today there are many more tools available to collect and concentrate pathogens (including
hollow-fiber ultrafiltration, nanoceramic filters, and glass wool filters) than there were in the past.
Dr. Hsu described an alternative approach to sample concentration, which involved the use of
functionalized silica beads to capture and remove viruses from water.
The goal of this project was to develop an electropositive silica matrix using functional chemical
groups to characterize the virus adsorption properties of each silica matrix using model viruses,
to develop an optimized surfactant-based elution buffer, and to validate the adsorption and
elution procedures for sampling large volumes of tap water.
Silica beads had many properties that may make them especially useful for pathogen collection.
For instance, silica chemistry is well established, a diversity of functional chemical groups is
available to attach to the surface of the silica beads, and silica beads provide good flexibility and
diversity because  they are not uniform in size and shape. His group conducted many experiments,
such as evaluating the capture and elution efficiency of bacteriophage MS-2 by prototype silica
beads. For that, the capture efficiency was very good (reaching 100% for several types of
functionalized silica beads, including APSI, APSII, and SLA), although elution reached only 9%.
However, as for the capture and elution of bacteriophage PRD-1  by prototype silica beads, the
best results were with APSII, which obtained an elution of 69.5%.
As a result  of this work, the researchers concluded that silica beads could be functionalized with
an assortment of chemical groups, and higher zeta potentials were associated with higher virus


                                           12

-------
capture efficiency. Combinations of functional group chain length and density yielded capture
efficiencies exceeding 95%. Functionalized silica beads could be "tuned" to achieve high
efficiency concentration for different virus groups.  Thus far, his group tested only MS-2 and
PRD-1 but plans to test other viruses.
Furthermore, it was observed that overall recoveries of viruses from functionalized DPS silica
beads range from 20% to 90% with alkaline beef extract or amino acid eluants (beef extract,
amino acids, and surfactant) and coliphage MS-2 could be recovered with efficiencies of 70% to
80% from 20-L  seeded volumes. The Scientific Methods group will continue to optimize the
functionalized silica beads and try to optimize the column geometry for large-volume samples.
This will include studying the column size, length, diameter, and flow rate.
Continuous Flow Centrifugation of Pathogens and Indicators from Large-
Volume Water Samples
Jim Larkin, Scientific Methods Incorporated

Dr. Larkin first noted that centrifugation is actually a very old and basic technique, developed as
a blood separation method called "blood fractionation", by Jack Latham of Arthur D. Little more
than 50 years ago. For CFC, the company Haemonetics has been central in developing this
technology. One significant modification was the development of a disposable plastic bowl to be
used for CFC. Dr. Larkin then noted other innovators in environmental microbiology who have
worked with centrifugation, including Jakubowski in 1982, Borchardt in the mid-90s to 2001,
and Tzipori in the mid-90s.
One important issue being addressed at the workshop is the fact that different matrices have an
impact on these different collection and concentration techniques. Another important issue is the
need for multiple pathogen concentration. Dr. Larkin showed an example of Giardia,
Cryptosporidium, andMicrosporidia being concentrated from the same samples by CFC.
He drew numerous conclusions about portable continuous-flow centrifuge (PCFC), including
that PCFC can concentrate protozoa from large volumes of water (10 to 1,000 L). PCFC also can
concentrate organisms from different types of water (i.e., finished, groundwater, surface water,
secondary wastewater), and it can concentrate multiple species of pathogenic protozoa.
As a result of his experiments, he concluded that it is possible to concentrate multiple
microorganisms using CFC. Cryptosporidium, Giardia, bacteria, and algae can be concentrated
inside the CFC bowl.  Additionally, viruses can be captured and eluted by positively-charged
filters after CFC.
In the future, Dr. Larkin's group intends to concentrate multiple pathogens with CFC by looking
at the following: large-volume water samples, continuous monitoring for pathogens and
indicators, sampling a variety of water types, capturing rare organisms that occur at low densities,
and investigating oligotrophic waters.
                                          13

-------
Day 2:  Invited Speaker Presentations and Panel Discussion
Summary of Previous Presentations
Ann Grimm, EPA

Dr. Ann Grimm provided an introduction for workshop attendees for the second day of the
meeting. She noted that in the workshop's first day there were interesting discussions pertaining
to ultrafiltration, the  1MDS electropositive filter and the potential for reusing the filter, glass
wool filters, nanoceramic filters, silica beads, and CFC. In the second day, discussion would
focus on microfluidics, alternatives to filtration, the iDEP technology, and field portability. She
observed that the talks have shown that the field has been advancing, and there appear to be
potential opportunities for EPA to invest and collaborate.
A Microfluidic Approach to Capturing and Concentrating Organisms from
Large Sample Volumes
Suresh D. Pillai and AH Beskok, Texas A  & M University

At the time of the conference, Dr. Suresh D. Pillai and Dr. Ali Beskok of the Texas A&M
University Bio-Micro-Fluidics Laboratory were completing an 18-month project funded by the
National Aeronautics and Space Administration. Dr. Pillai began the presentation by describing
the importance of concentration. Robust technology able to collect and concentrate a range of
pathogens is needed for water quality monitoring. It is also vital that it be compatible with
current and future detection technologies, e.g., PCR, biosensors, arrays.
In a clinical sample, it is much easier to detect an organism because the numbers of organisms
per unit sample are  much higher, whereas, in a water sample, the concentration of organisms is
often only between  1 and 10 organisms per liter. Therefore, to develop a very robust system it is
necessary to understand the first principles of how organisms attach to matrices. Until this is
done, everything else is simply observation. If only recovery and capture efficiencies are
considered, it might not be possible to understand why a system might fail. Consequently, some
components of this  work are outside the core competencies of microbiologists, and so engineers
and physicists could play a critical role in developing effective collection and concentration
methods.
Dr. Beskok then discussed the use of electrophoresis in pathogen isolation. His group looked into
the concentration of bacteria and viruses using this technology, noting that these organisms
mostly are negatively charged, even over the wide range of pH seen in various water matrices.
Consequently, the group decided to use electrophoretic transport in a microfluidic channel to
transport microorganisms toward electrode surfaces and to capture the microorganisms using
electrostatic mechanisms.
Finally, Dr. Pillai noted that even if an organism is captured on a positively charged surface,
eluting the organism can be a challenge. He therefore is trying to embed sensors into the surface,
integrating sensors with capture. His group wants to optimize this real-time detection on the
                                          14

-------
capture unit. Also, his group recently signed a working agreement with Luna Innovations, which
is working with off-the-shelf detection sensors. The group plans to, among other things, explore
terahertz sensors to detect the capture of organisms.
Note: In May 2008, Dr. Suresh D. Pillai and Dr. AH Beskok provided the follow ing publications:
Pillai, SD., Beskok, A., Balasubramanian, AK., and Soni, KA. 2006. A microfluidic device for
    capture and concentration of microorganisms in recycled water. Habitation  10: 224.
Balasubramanian, AK, Beskok, A., and Pillai, SD. 2007. In-situ analysis of bacterial capture in a
    microfluidic channel. Journal of Micromechanics andMicroengineering 17:1467-1478.
Balasubramanian, AK., Soni, KA., Pillai, S.D. and Beskok, A. 2007. A microfluidic device for
    continuous  capture and concentration of pathogens from potable water. Lab on a Chip
    7:1315-1321.
Soni, KA., Balasubramanian, AK., Beskok, A., and Pillai SD. 2008. Zeta potential of selected
    bacteria in drinking water when dead, starved, or exposed to minimal and rich culture media.
    Current Microbiology 56: 93-97.
A High-Volume Alternative to Filtration Based on Adsorption and Elution
Mike Kent, Sandia National Laboratory

Dr. Kent's project involved the development of a method for concentrating bacteria and viruses
from streams. It was done with the support of a biosensor developed at Sandia by other groups.
The handheld sensor can detect a range of different organisms within 15 minutes, and it is based
on protein fingerprinting. The goal of the project was to detect 103 cells/mL by preconcentrating
tolO7 cells/mL, but, after listening to the workshop discussion, it was apparent that this is a
relatively concentrated level of pathogens, and that participants are interested in detecting 1 cell
per liter. This method had to be portable, low cost, low power, and consistent with the detection
scheme, so that no proteins could be introduced. For this work, two approaches were  pursued.
One was to use temperature-responsive polymer, PNIPAM, to reversibly block and open pores in
a column or a micro capillary. The other—the focus of his talk—was to adsorb bacteria and
viruses from solution onto a high-surface-area media through nonspecific interactions and
release by elution. To do this, he used glass beads that generally ranged from 300 to 400 um. Dr.
Kent noted that his group chose to use hydrophobic surfaces to bind the pathogens, placing
emphasis on looking for chemical agents that maximized the efficiency of elution. He found one
of the best elution agents to be sodium dodecyl sulphate (SDS). Dr. Kent indicated that SDS can
be disadvantageous in that it lyses vegetative cells, but that this was not an issue for his group
because the cells have to be lysed anyway in their detection method, which is based on protein
fingerprinting (although that made it difficult to count). He added that the group has found
efficient elution agents similar in structure to SDS that do not lyse the cells, and these are based
on lipids (where one can use plate counts).
Dr. Kent's group spent a lot of time doing flow cell experiments looking at the efficiency of
release of cells from the surface. They examined two organisms: (1) Bacillus atrophaeus and (2)
Chattonella  marina, and most of the work was with SDS, using nucleic acid extraction and
elution with SDS. The capture for the two organisms in the vegetative state has generally been in
the range of 70% to 90%. Other experiments, including those with spores of Bacillus atrophaeus,
                                           15

-------
showed that they routinely got elution peaks that were several orders of magnitude above
background. Recovery efficiencies varied from 50% to below 10%, which are low values
compared to results reported in Day 1 of the workshop. He closed by noting that he has done
elution experiments with lipids, and they obtained efficient elution, but again, had low recovery
efficiencies. In sum, with hydrophobic surfaces, one can maximize the elution efficiency and
adsorption for a couple of species. Flow rate was not extensively examined.
Design, Fabrication, and Testing of Polymeric Microfluidic Separators and
Concentrators Utilizing Insulator-Based Dielectrophoresis (iDEP)
Blake Simmons, Sandia National Laboratory

Sandia National Laboratory has been conducting research on insulator-based dielectrophoresis
over the past five years. The motivation for this work has been the need for pathogen monitoring,
which is a global health and security issue. There has been a growing interest, both from a
homeland security standpoint and from a water quality monitoring standpoint, to be able to
effectively monitor large volumes of water for very low concentrations of organisms—ideally
one organism per liter. Traditional water analysis methods typically involve lengthy steps, such
as culturing or mechanical filtration, and there are a lot of problems associated with the recovery
and efficiency of those systems. The need for the selective concentration, as well as sensitive
detection of pathogens, is therefore very great. However, there is usually an inverse relationship
between selectivity and sensitivity. Thus, the question is, how can a system that provides both
sensitivity and selectivity be engineered?
Sandia National Laboratory has a number of multiuse technologies relevant to water monitoring
(examples include a Liquid microChemLab and a Gas microChemLab). In this presentation, he
focused on Sandia's biological preconcentrator; it is  an insulator dielectrophoresis to sort and
preconcentrate bacteria.
The goal of his group was to develop a selective concentrator with significant flow rates. He
noted that dielectrophoresis is a physically selective nonlinear electrostatic transport mechanism.
He said such technology can be a highly sensitive sorting technique.
Dr. Blake Simmons said that Sandia developed a system that is very powerful, robust, and simple.
It is a device that can separate particles from a background of various matrices in multiple
formats. The polymer chip performance is comparable to the glass devices. Sandia also had
initiated an integrated systems engineering approach to couple particle sorting and detection in
one platform to provide the sensitivity and selectivity desired. Additionally, the group's
experience indicated that the technology could be scaled from nanoliters per minute to milliliters
per hour.
Sandia was exploring other techniques to produce sensitive and selective devices, alternate
device  geometries, and different configurations. Also, Sandia had a path forward to
commercialization, with a couple of Cooperative Research and Development Agreements and
licensing agreements to develop the iDEP technology for aerosol monitoring. Finally, it has been
moving to alternative device architectures, such as continuous flow. Sandia recently developed a
design  that it hopes will allow for a flow rate of multiple liters per hour, as opposed to less than a
liter per hour.
                                           16

-------
Making a Lab Process Field Portable
Michael Carpenter, Idaho National Laboratory

This project represented collaboration between a developing EPA laboratory process and an INL
concept designed to embrace a new sample concentration paradigm, bringing the laboratory to
the field.
The EPA has identified the need for a portable, automated field sample concentrator. The current
concentrator exists as a laboratory scale process, and Dr. Carpenter said that INL was tasked to
produce an automated prototype, man-portable field system. This concentrator system will be
applied to monitoring municipal water supplies, public event potable water supply screening
activities, and first-responder sample collection.
The project's objectives are to achieve a 400-fold initial sample reduction from 100 L to 250 mL;
to reduce and control the sample collection rate variability; to make the system portable, simple
to use, lightweight, rugged,  and partially disposable (wet parts must be disposable and low-cost);
and to maintain biohazard containment.
Phase-1 development of the control software for the prototype automated system had been done,
and the prototype-1 system was complete. EPA will use the first prototype to evaluate recovery
rates, variability between system runs, various filter model recovery performance, and various
components of the  system. The test information from the prototype will be used to design a
second prototype, as well as subsequent designs.
Various obstacles in moving the work from a laboratory-based manual system to an automated
portable field system have been encountered. The overall goal of the work has been to automate
operation of the system to the greatest extent possible, which signifies a balancing act between
expediency and technical necessity.
With regard to the process undertaken to pursue this project, the INL evaluated the benchtop
ultrafiltrator concentrator (UC) process that required manual intervention to adjust operational
parameters such as flow rates, pressures, elution, and back-flush operations. Working closely
with EPA, INL proposed the initial  system concept to EPA. After some review and changes, INL
set up a benchtop system very similar to the current EPA method and introduced initial
automated features. INL developed proprietary software executable to automatically operate the
UC concept system within initially established parameters.
The reality of water security threats to long-standing infrastructure requires  a paradigm shift in
traditional laboratory methods. The laboratory simply has to be where the problem is, and the
ultrafiltration concentrator allows a laboratory process to be taken to the field.
In the future, the group will  continue testing concentrators in broader applications. Additionally,
they will plan production and distribution of concentrators to municipalities and to County, State,
and Federal agencies. INL Environmental Engineering will manage the subcontract
manufacturing of multiple units in those contracts, and INL will provide technical support and
system control training to the user base. The design will evolve as concentrator requirements
evolve.
                                           17

-------
Summary
James Sinclair, EPA

At the end of all the presentations, James Sinclair, of the EPA OGWDW's Technical Support
Center, summarized the presentations as follows:

• There were a range of interesting talks on a variety of different techniques, from continuous
  flow centrifugation, to hollow-fiber filters, to silica beads. Participants exchanged a great deal
  of data on the recovery efficiencies of the different technologies.

• The technologies all were demonstrated to offer noteworthy advantages, including the
  following highlights:
   o Hollow-fiber filters had a major benefit in that they allowed for the simultaneous
     concentration of viruses, bacteria, and protozoa.
   o Virosorb  1 MDS virus cartridge filters could be reused three times since there was no viral
     carryover after treatment.  Also, filters could receive additional treatment to remove
     nucleic acids.
   o Glass wool filters were sufficiently inexpensive that they allowed for a large occurrence
     study that would not otherwise be feasible. The filters worked with large volumes of water,
     and different viruses and water types yielded between 8% and 98% recovery.
   o  Electropositive nanoaluminum-fiber filters were shown to allow high flow rates. They also
     could hold a large amount of particulate material and retain a  variety of microorganisms
     well.
   o Silica bead virus filters also had good recovery. The addition  of different functional groups
     increased the capture of the viruses as compared with the uncoated silica beads alone. The
     capture efficiency could be optimized for different viruses.
   o Continuous-flow centrifugation was another valuable technique and could be used for
     bacteria and protozoa. It was inexpensive as well, with consumables costing about $50.
     The flow rate was between 100 and 700 mL/minute, but better recoveries were obtained
     with the lower flow rates and higher centrifugation speeds.
   o A chemical affinity based approach on hydrophobic interactions was demonstrated be able
     to concentrate bacteria and viruses. Different eluting agents were used, but SDS was found
     to be the best.  Adsorption and elution occurred efficiently, but bacteria appeared to be
     trapped on the thread, so more optimization was needed.
   o Electrophoresis was illustrated to transport and trap bacteria and viruses in a microfluidic
     device. Microorganisms are separated in a microchannel based on their charge and
     mobility under an electric field. The device was tested with different bacteria, viruses, and
     water types and under different operating conditions. Recoveries often exceeded 90%.
   o Dielectrophoresis, which is based on the movement of particles from polarization in a
     nonuniform electrical field, could separate particles based on  characteristics other than size.
   o Portable sampling systems will be important for more extensive field testing.
                                           18

-------
Panel Discussion

An open-panel discussion followed the presentations. Dr. Parshionikar first asked the panel
which technology, in their opinion, was the most promising that EPA could pursue. Dr. Suresh
Pillai was of the opinion that continuous-flow centrifugation was promising simply because of its
ease and simplicity. He also thought that microfluidics was a promising field that could be scaled
up to meet the requirements of large-volume water sampling. He noted that it was important to
understand how pathogens interacted with their matrices, and that it was not enough to simply
study capture and recovery efficiencies of pathogens. Dr. Parshionikar then asked Dr. Simmons
for his  thoughts on whether the iDEP technology could be used to distinguish between live and
dead viruses.  She wondered if, after the initial elution and concentration step, the viral
concentrate could be passed through the microfluidic channels of an iDEP and observe a
differential migration pattern between dead and live viruses. Dr. Simmons answered that it had
not been tried, but thought it might work, and was open to collaborative opportunities. Dr.
Gerard Stelma asked the panel why large volumes of water had to be used when sampling for
viruses. The panel answered that the viruses and parasites often are thought to be present in low
concentrations in contaminated water but could pose a health risk, as some early studies have
shown  the infectious dose of viruses to be very low. It therefore was thought that the larger the
volume of water, the more useful the data can be. Eunice Varughese asked how we could address
the issue of pathogen attachment to solid particles, as this may affect recovery efficiencies. Dr.
Hill answered that this indeed was a problem that he has had to deal with, but as yet, did not have
a solution. Dr. Parshionikar asked the panel if the nanoceramic particles mentioned in Dr.
Tepper's talk had different binding efficiencies to nucleic acids and whole organisms. The panel
answered that the binding efficiency was the same for the two.
In summary, the following themes emerged from the panel discussion (please note that these
themes do not constitute recommendations):

• There is a need for a method that could simultaneously recover multiple pathogens.

• The method must work with current and future detection methods such as PCR, microarrays,
  and biosensors.

• Variability  in recovery efficiency is a major problem with many filter technologies.

• Microfluidics seem to hold promise if the technology could be scaled up for large sample
  volumes.
                                           19

-------
Closing Statement
Sandhya Parshionikar, EPA

Dr. Sandhya Parshionikar thanked the presenters and participants and acknowledged that
pathogen capture and detection has come a long way since its very primitive days in the 1960s.
She noted that the technologies presented at the workshop look promising, but it remains to be
seen if they can withstand the demands of downstream molecular detection. One option for the
future could be using a combined approach, in which different technologies could be combined
to come up with a complete, optimized concentration method. Despite all the efforts that still
need to be made in this field, the future seems promising.
                                         20

-------
List of Participants
Adam Bange
All Beskok
Jennifer Best
Mark Borchardt
Susan Boutros
Kristin Brenner
Michael Carpenter
Gregory Carroll
Jennifer Cashdollar
John Chandler
Terry Covert
Daniel Dahling
Maura Donohue
Otis Evans
Debbie Flanigan
Shay Fout
Stephanie Friedman
Vince Gallardo
Gerard Stelma
Ann Grimm
Brian Hasall
Jafrul Hasan
Rich Haugland
Samuel Hayes
Elizabeth Hedrick
Vincent Hill
Ahmed Hosni
Christon Hurst
Fu-chi Hsu
Michael Kent
Kaci Klenk
University of Cincinnati
Texas A&M University
EPA
Marshfield Clinic Research Foundation
Environmental Associates Ltd
EPA
Idaho National Laboratory
EPA
EPA
Computer Sciences Corporation
Shaw Environmental Inc.
EPA
EPA
EPA
EPA
EPA
EPA
EPA
EPA
EPA
University of Cincinnati
EPA
EPA
EPA
EPA
CDC
University of Cincinnati
EPA
Scientific Methods Inc.
Sandia National Laboratory
USDA
                                        21

-------
Jim Larkin
Ian Laseke
Christina Likirdopulos
Alan Lindquist
Paul McCauley
Audrey McDaniels
John Meschke
Matthew Morrison
Carrie Miller
Yolanda Olivas
John Olszewski
Kevin Oshima
Jim Owens
Sandhya Parshionikar
Suresh Pillai
Stacy Waller
Shane Rogers
Nancy Schable
Kevin Schlueter
Keya Sen
Blake Simmons
Otto Simmons
Jim Sinclair
Fred Tepper
Umadevi Tiwari
Eunice Varughese
Eric Villegas
Mike Ware
Joseph Williams
Scientific Methods Inc.
University of Cincinnati
USGS
EPA
EPA
EPA
University of Washington
EPA
EPA
EPA
EPA
EPA
EPA
EPA
Texas A&M University
EPA
EPA
EPA/ORISE Fellow
University of Cincinnati
EPA
Sandia National Laboratory
University of North Carolina
EPA
Argonide Inc.
University of Cincinnati
EPA
EPA
EPA
EPA
                                        22

-------
23

-------