CBP/TRS 148/96
                          EPA903-R-96-006
Recommended Guidelines for
Sampling and Analyses in the
      Chesapeake Bay
    Monitoring Program

         August 1996
      Chesapeake Bay Program

-------
 Recommended Guidelines for
 Sampling and Analyses in the
        Chesapeake Bay
     Monitoring Program
           August 1996
       Chesapeake Bay Program
Printed by the U.S. Environmental Protection Agency for the Chesapeake Bay Program

-------
                                                                                    August 1996
                            TABLE OF CONTENTS
TABLE OF CONTENTS	  i

LIST OF FIGURES  (List is omitted from electronic version)	vi

LIST OF TABLES	iv

CHAPTER I - INTRODUCTION

       Section A.      Overview	1-2
              1.       Purpose of the SOW	1-2
              2.       Organization of the SOW 	1-2
              3.       Quality Assurance considerations	1-3
              4.       Health and Safety considerations  	1-3
              5.       Other Federal and State Requirements	1-4
              6       Future considerations  	1-4

       Section B.      Summary of Requirements   	1-5
              1.       SOW Task Areas	1-5
              2.       Personnel Requirements	1-7
              3.       Facilities	1-12
              4.       Instrumentation and Equipment	1-13


CHAPTER II - QUALITY ASSURANCE

       Section A.      Introduction	II-3

       Section B.      General QA/QC Requirements	II-4
              1.       Reporting	II-4
              2.       Chain-of-Custody	II-6
              3.       Participation in Technical Meetings	II-6
              4.       Procedural Change Authorization	II-7

       Section C.      Field QA/QC Procedures	II-9
              1.       Annual Calibration	II-9
              2.       Calibration Check	II-9
              3.       Check Sample	II-9

       SectionD.      Laboratory QA/QC Procedures	11-10
              1.       MethodBlank	11-10
              2.       Matrix Spike	11-10
              3.       Laboratory Replicates	II-l 1
              4.       Check Standard	11-12
              5.       Glassware Cleaning	11-12

-------
                                                                                        August 1996

        Section E.       Data Quality Objectives	11-14
               1.       General DQO's	11-14
              2.       Sampling	11-17
              3.       Field Measurements	11-17
              4.       Water Quality Monitoring	11-18
               5.       Phytoplankton Monitoring	11-19
               6.       Zooplankton Monitoring	11-19
               7.       Benthic Monitoring	11-20

        Section F.       Documentation Recommendations	11-21
               1.       Quality Assurance Plan	11-21
               2.       Quality Assurance Project Plans	11-24
               3.       Standard Operating Procedures	11-24
               4.       Document Control	11-26
               5.       Contingency and Health and Safety Plans	11-28

        Section G.       Performance Assessment	11-29
               1.       Split Sample Program	11-29
               2.       Performance Evaluation Samples	11-30
               3.       Audits of Data Quality	11-30
               4.       On-site Audits	11-30

        Section H.       References	11-32

CHAPTER III - DATA MANAGEMENT AND DELIVERABLES REQUIREMENTS
        Section A.       Automation of Data Collection	III-2
               1.       Introduction	III-2
               2.       Development Phase	III-2
               3.       Training	III-3

        Section B.       Hardware Requirements for Automated Entry and Storage	III-4
               1.       Minimum Requirements	III-4

        Section C.       Contract Reports and Deliverable Distribution	III-5
               1.       Deliverables	III-5
               2.       Archive of Results	III-5
               3.       Data Dictionary	III-5

CHAPTER IV - WATER QUALITY MONITORING

        Section A.       Introduction	IV-2
               1.       Objectives and Scope	IV-2
              2.       Rationale	IV-2

        Section B.       WQ Parameter List and Detection Limits	 IV-3

        Section C.       Field Measurements and Sampling	IV-4
               1.       Introduction	IV-4
              2.       Field Measurements	IV-8
              3.       Sampling	IV-11
                                                  11

-------
                                                                                        August 1996
        Section D.      Laboratory Analysis	IV-16
               1.       General Laboratory QA/QC	IV-16
              2.       Total Dissolved Phosphorus	IV-20
              3.       Dissolved Orthophosphate	IV-25
              4.       Particulate Phosphorus	 IV-30
              5.       Nitrite	IV-36
              6.       Nitrate + Nitrite	IV-42
              7.       Ammonia	IV-50
              8.       Total Dissolved Nitrogen/Particulate Nitrogen	IV-55
              9.       Particulate Carbon	IV-65
              10.       Dissolved Organic Carbon	IV-70
              11.       BOD, 5 day	IV-74
              12.       Chlorophyll and Phaeophytin	IV-79
              13.       Total Suspended Solids	IV-83
              14.       Fixed Suspended Solids	IV-86
              15.       Silicates	IV-88
              16.       Alkalinity	IV-92
Addendum
        1. Revised Method for Chlorophyll and Pheophytin - June 1999
                                                  ill

-------
                                                                                         August 1996
                                           LIST OF TABLES
Table II. 1.  Data Quality Objectives for Field
                        Measurements	11-17
Table II.2.  Precision, Accuracy, and Completeness
                        Objectives for Water Quality Monitoring	11-17

Table II.3.  Precision, Accuracy, and Completeness
                        Objectives for Water Quality Monitoring	11-18

Table II.4.  Precision, Accuracy, and Completeness
                        Objectives for Phytoplankton Monitoring	11-19

Table II.5.  Precision, Accuracy, and Completeness
                        Objectives for Zooplankton Monitoring	11-19

Table II.6.  Precision, Accuracy, and Completeness
                        Objectives for Benthic Monitoring	11-20

Table IV. 1.  WQ Parameter List and Detection Limits	IV-3

Table IV.2.  Sampling Station Locations	IV-6

Table IV.3.  Cruise Schedule for 1992	IV-8

Table IV.4.  WQ Laboratory Parameter Holding Times and Temperatures	IV-16
                                                  IV

-------
                                                                              Chapter I
                                                                           Introduction
                                                                           August 1996
                               CHAPTER  I
                         INTRODUCTION
Section A.      Overview

       1.      Purpose of the document
       2.      Organization of the document
       3.      Quality Assurance Considerations
       4.      Health and Safety Considerations
       5.      Other Federal and State Requirements
Section B.      Summary of Requirements

       1.      Document Task Areas
       2.      Personnel Requirements
       3.      Facilities
       4.      Instrumentation and Equipment
                                          1-1

-------
                                                                                                     Chapter I
                                                                                                 Introduction
                                                                                                 August 1996
                                          SECTION A


                                     INTRODUCTION

1.       Purpose of this document

        The purpose of this document is to provide field and laboratory methods and associated quality control (QC)
        procedures and criteria that will result in the generation of data of known and documented quality for use in the
        Chesapeake Bay Monitoring Program.  Under this document, the Participant will conduct field measurements and
        collect and analyze water and sediment samples for specific physical, chemical, and biological parameters that are in
        accordance with Appendix F and previous data collection efforts. These monitoring data will be used in
        characterizing the health of the Chesapeake Bay and its tributaries, identifying long term trends, and providing data
        and guidance to managers and modelers during the restoration phase.


2.       Organization of the document

        2.1      This document includes the requirements and procedures for field measurements, field sampling, and
                laboratory analysis in support of the Chesapeake Bay Monitoring Program.  The first chapters provide
                general information regarding technical and contractual requirements, and the remaining chapters have been
                organized so as to correspond chronologically with the  field and laboratory activities performed.

        2.2      Specifically, this document has been organized as follows:

                2.2.1    Chapter I provides a summary of the technical and management requirements established to ensure
                        attainment of Program objectives.

                2.2.2    Chapter II defines the Quality Assurance (QA) protocols and procedures that have been developed
                        for this document including specific requirements for QA procedures.  It outlines the chain-of-
                        custody and document control procedures which shall be followed with every sample.

                2.2.3    Chapter III specifies all reporting requirements, data management procedures, and software
                        procedures. It provides the deliverables and turnaround times required by this Scope of Work
                        (SOW).

                2.2.4    Chapter IV presents specific methods and procedures for water quality monitoring including
                        sampling, field measurements, and analysis and the associated QC requirements.


3.       Quality Assurance Considerations

3.1      The Participant must be aware of the importance of maintaining  the integrity of the data  generated under
        this contract, as the data may be used to make important decisions regarding the characterization and
        restoration of the Chesapeake Bay.  Data integrity is defined as ensuring that data are complete, consistent,
        and without errors, and ensuring the prevention of information corruption and unauthorized data
        modification.


                                                  1-2

-------
                                                                                               Chapter I
                                                                                           Introduction
                                                                                           August 1996
3.2     Participants will adhere to generally acceptable field and laboratory practices and good automated field and
        laboratory practices. Good automated practices for this SOW comprise the data management procedures
        described in Chapter III of this SOW. All procedures shall be carried out by qualified field laboratory
        personnel to ensure the quality and integrity of the monitoring data being produced.  By following the
        specific analytical and reporting procedures outlined in this document, the Participant will produce
        monitoring data of known and documented quality. Additional requirements for maintaining generally
        acceptable practices and good automated practices are provided throughout this SOW.

4.       Health and Safety Considerations

4.1     The samples to be collected and analyzed by the Participants' are from the Chesapeake Bay mainstem and
        tributaries and may contain hazardous materials which could present a risk to human health and a hazard to
        field and laboratory instrumentation/equipment. The Participant should be aware of the potential hazards
        associated with the handling and analyses of these samples. It is the Participants' responsibility to take all
        necessary measures to  ensure the health and safety of its employees, and to maintain its analytical
        instruments in good working condition.

4.2     The Participant will comply with all applicable Occupational Safety and Health Administration (OSHA)
        requirements.

4.3     The Participant will comply with the applicable requirements as stated in "Health and Safety Protocols for
        EPA Vessels," which has been included as an appendix to this SOW.  This document will become a chapter
        of the EPA Health and Safety Manual.  All contractors are expected to comply with all EPA health and
        safety requirements. However,  the contractor should develop their own Manual to reflect their operating
        conditions.

4.4     All vessels used to collect samples from the Chesapeake Bay mainstem monitoring stations will be in full
        compliance with state and federal regulations regarding the use of tributyltin (TBT) anti-fouling paints.
        Regulations ban the use of paint containing TBT to marine contractors and boatyards.

4.5     All vessels used to collect samples will be in compliance with Section 312 of the Water Quality Act of 1987
        which requires the installation of marine sanitation device (MSD) on all vessels with installed toilets
        operating in the navigable waters of the United States. Type III MSDs, which are designed to prevent the
        discharge of human waste from boats in any form, will be used.

5.       Other Federal and State Requirements

5.1     The Participant will comply with all relevant State and Federal laws and regulations, including the
        Resource Conservation Recovery Act (RCRA) and the Clean Water Act (CWA).

5.2     Because some substance used in the sample preparation and analysis procedures described in this SOW are
        hazardous (e.g., formalin and inorganic acids), appropriate state and federal regulations must be followed
        for their handling and disposal both in the laboratory and in the field.
                                                  1-3

-------
                                                                                             Chapter I
                                                                                         Introduction
                                                                                         August 1996
                                          SECTION B


                        SUMMARY OF REQUIREMENTS

1.       Document Task Areas

1.1      For each sample, the Participant will perform certain tasks. These tasks are: (1) development of a sampling
        schedule; (2) performance of field measurements; (3) collection, preparation, and transport of field samples;
        (4) laboratory receipt and preparation of field samples; (5) chemical and biological analyses of field
        samples; (6) adherence to QA/QC procedures outlined in this document; and (7) data management and
        reporting.

1.2      These tasks are specifically outlined as follows.

        1.2.1    Task 1. Development of a sampling schedule.

                1.2.1.1 The Participant will  develop a sampling schedule that complies with the frequency and
                       location requirements established in this document. This schedule shall be developed in
                       close coordination with the VADEQ, the CBPO, and the State of Maryland.

                1.2.1.2 The Participant will  ensure compliance with the sampling schedule through the
                       development and use of contingency plans.

                1.2.1.3 The Participant will  visit each sampling station as specified in Chapter IV, and verify and
                       record site location according to procedures specified in each Chapter.

                1.2.1.4 The Participant will  transport the sampling crew and all necessary sampling and field
                       measurement equipment and ensure that they are capable of meeting the specified data
                       quality objectives.

        1.2.2    Task 2. Performance of field measurements.

                1.2.2.1 The Participant will  measure physical and chemical parameters as defined in Chapter IV.

        1.2.3    Task 3. Collection, preparation, and transport of field samples.

                1.2.3.1 The Participant will  develop and implement field chain-of-custody procedures as
                       described in Chapter II.

                1.2.3.2 The Participant will  collect samples as described in Chapter IV.

                1.2.3.3 The Participant will  prepare and preserve samples as described in Chapter IV.


                1.2.3.4 The Participant will  transport samples as described in Chapter IV.

        1.2.4    Task 4. Laboratory receipt and preparation of field samples.
                                                 1-4

-------
                                                                                      Chapter I
                                                                                   Introduction
                                                                                   August 1996
        1.2.4.1  The Participant will develop and implement laboratory chain-of-custody procedures as
                described in Chapter II.

        1.2.4.2  All CBP monitoring samples shall be received and logged by the sample custodian.

        1.2.4.3  The Participant will provide adequate storage for CBP samples awaiting analysis.

        1.2.4.4  The Participant will follow the applicable sample preparation procedures outlined in this
                document.

1.2.5    Task5.  Chemical and biological analyses of field samples.

        1.2.5.1  Samples shall be analyzed by the techniques described in the methodologies given in
                Chapters IV through VII for the target parameters listed.

        1.2.5.2  Samples must be analyzed within the maximum specified holding times.

1.2.6    Task 6.  Adherence to QA/QC procedures outlined in this SOW.

        1.2.6.1  The Participant will adhere to all QA procedures described in Chapter II and all specific
                QC procedures described in Chapters IV, V, VI, and VII. Records documenting the use
                of the specified QC protocols shall be maintained in accordance with the document
                control procedures described in Chapter II.

        1.2.6.2  The Participant will establish a Quality  Assurance Plan (QAP) with the objective of
                providing sound monitoring data. This  program shall incorporate the QC procedures, any
                necessary corrective action, and all documentation required during data collection, as  well
                as the quality assessment measures performed by management to ensure acceptable data
                production.

        1.2.6.3  Additional QC may be conducted in the form of the analysis of Performance Evaluation
                (PE) check samples submitted to the Participant by the CBPO.  The results of all such
                control or PE check samples may be used for performance evaluation. "Compliant
                performance" is defined as that which yields correct compound identification and
                concentration values as determined by the CBPO, as well as meeting the method
                requirements for analysis, quality assurance/quality control, data reporting and other
                deliverables; including sample custody, sample documentation, and SOP documentation.

1.2.7    Task?.  Data management and reporting.

        1.2.7.1  Samples will be analyzed and the data reported to EPA within the turnaround times of 3
                months from the last day of sampling. The Participant will prepare electronic and
                hardcopy data according to the procedures outlined in Chapter II and will report
                electronic and hardcopy data according  to the formats, order, and turnaround times
                according to this document.
                                          1-5

-------
                                                                                              Chapter I
                                                                                           Introduction
                                                                                           August 1996
2.       Personnel Requirements

2.1     The Participant will provide technical expertise for this contract.

2.2     The Participant will designate and use key personnel to perform the functions described below.  The
        VADEQ and the CBPO reserve the right to review personnel qualifications and experience, and take
        contract action as appropriate.

2.3     The Participant should have an organization with well-defined responsibilities for each individual in the
        management system to ensure sufficient resources for this contract and to maintain a successful operation.
        To establish this capability, the Participant will designate personnel to carry out the following
        responsibilities for this contract.  Functions include, but are not limited to, the following:

        2.3.1    Project Manager

                Responsible for all aspects of this contract (from sample collection through data delivery) and shall
                be the primary contact for the VADEQ and CBPO. The project manager shall be responsible for
                the technical and management aspects of the contract and shall  ensure that all contractual
                requirements are met.

                Qualifications:

                        Education:

                        Minimum of Masters degree in chemistry, biology, or  any scientific/engineering
                        discipline.

                        Experience:

                        Minimum of 2 years of field experience, 2 years of laboratory experience, and 1 year of
                        project management experience.

        2.3.2    Field Supervisor

                Responsible for all field activities performed under this contract.

                Qualifications:

                        Education:

                        Minimum of Bachelor's degree in chemistry, biology,  or any scientific/engineering
                        discipline.

                        Experience:

                        Minimum of 4 years of field experience, including at least one year of supervisory
                        experience.
                                                  1-6

-------
                                                                                        Chapter I
                                                                                     Introduction
                                                                                    August 1996


2.3.3    Water Quality Laboratory Supervisor

        Responsible for all technical efforts of the water quality laboratory to meet all terms and
        conditions of this contract.

        Qualifications:

                Education:

                Minimum of Bachelor's degree in chemistry or any scientific/engineering discipline.

                Experience:

                Minimum of 4 years of water quality laboratory experience, including at least one year of
                supervisory experience.

2.3.4    PhytoplanktonLaboratory Supervisor

        Responsible for all technical efforts of the phytoplankton laboratory to meet all terms and
        conditions of this contract.

        Qualifications:

                Education:

                Minimum of Bachelor's degree in bio logy or any life science discipline.

                Experience:

                Minimum of 4 years of phytoplankton laboratory experience, including at least one year
                of supervisory experience.

2.3.5    ZooplanktonLaboratory Supervisor

        Responsible for all technical efforts of the zooplankton laboratory to meet all terms and conditions
        of this contract.

        Qualifications:

                Education:

                Minimum of Bachelor's degree in bio logy or any life science discipline.

                Experience:

                Minimum of 4 years of zoological laboratory experience, including at least one year of
                supervisory experience.

2.3.6    Benthic Laboratory Supervisor
                                           1-7

-------
                                                                                       Chapter I
                                                                                    Introduction
                                                                                   August 1996
        Responsible for all technical efforts of the benthic laboratory to meet all terms and conditions of
        this contract.

        Qualifications:

                Education:

                Minimum of Bachelor's degree in bio logy or any life science discipline.

                Experience:

                Minimum of 4 years of benthic laboratory experience, including at least one year of
                supervisory experience.

2.3.7    Quality Assurance Officer

        Responsible for overseeing the quality assurance aspects of contract data and reporting directly to
        upper management to meet all terms and conditions of this contract.

        Qualifications:

                Education:

                Minimum of Bachelor's degree in chemistry or any scientific/engineering discipline.

                Experience:

                Minimum of 3 years of field and laboratory experience, including at least one year of
                applied experience with QA principles and practices in sampling and analytical
                procedures.

2.3.8    Sample Custodian

        Responsible for receiving the EPA samples (logging, handling, and storage).

        Qualifications:

                Education:

                Minimum High School Diploma with four or more science courses.

                Experience:

                Minimum of 2 years experience receiving and logging scientific samples.

2.3.9    Data Systems Manager
        Responsible for the management and quality control of all computing systems (hardware, software,
        documentation, and procedures), generating, updating, and quality controlling automated
        deliverables to meet all terms and conditions of this contract.

-------
                                                                                      Chapter I
                                                                                   Introduction
                                                                                  August 1996
        Qualifications:

                Education:
                Minimum of Bachelor's degree with four or more intermediate courses in programming,
                information management, database management systems, or systems requirements
                analysis.

                Experience:

                Minimum of 3 years experience in data or systems management or programming
                including one year of experience with software utilized for data management and
                generation of data deliverables.

2.3.10   Field personnel

        Responsible for field measurements and collection of monitoring samples in accordance with this
        SOW.

        Qualifications:

                Education:

                Minimum of Bachelor's degree in chemistry or any scientific/engineering discipline.

                Experience:

                One year of experience sampling water, benthos, and plankton in estuarine waters.
                Specifically, experience in using the field instrumentation and sampling devices cited in
                this SOW.

2.3.11   Water Quality Laboratory personnel

        Responsible for the analysis of samples in accordance with this SOW.

        Qualifications:

                Education:

                Minimum of Bachelor's degree in chemistry or any scientific/engineering discipline.

                Experience:

                One year of experience analyzing nutrients and water quality parameters. Specifically,
                experience with the instrumentation and methods cited in this SOW.


2.3.12   Phytoplankton Laboratory expert

        Responsible for the analysis of phytoplankton samples in accordance with this SOW.


                                          1-9

-------
                                                                                       Chapter I
                                                                                   Introduction
                                                                                   August 1996
        Qualifications:

                Education:

                Minimum of Bachelor's degree in biology or any life science discipline.

                Experience:

                One year of experience analyzing water samples for phytoplankton.  Specifically,
                experience with the instruments and techniques cited in this SOW.


2.3.13   Zooplankton Laboratory expert

        Responsible for the analysis of zooplankton samples in accordance with this SOW.

        Qualifications:

                Education:

                Minimum of Bachelor's degree in biology or any life science discipline.

                Experience:

                One year of experience analyzing water samples for zooplankton.  Specifically,
                experience with the instruments and techniques cited in this SOW.


2.3.14   Benthic Laboratory expert

        Responsible for the analysis of benthic samples in accordance with this SOW.

        Qualifications:

                Education:

                Minimum of Bachelor's degree in biology or any life science discipline.

                Experience:
                One year of experience analyzing benthic samples.  Specifically, experience with the
                instruments and techniques cited in this SOW.

2.3.15   Data Management Analyst

        Responsible for the operation and maintenance of software and programs generating, updating and
        quality controlling analytical databases and automated deliverables to meet all terms and
        conditions of this contract.


                                          1-10

-------
                                                                                               Chapter I
                                                                                            Introduction
                                                                                           August 1996
                Qualifications:

                        Education:
                        Minimum of Bachelor's degree with four or more intermediate courses in information
                        management, information systems, database management systems, or systems
                        requirements analysis.

                        Experience:

                        Minimum of two years experience in systems or including one year of experience with
                        the software being utilized for data management and generation of data deliverables.
3.       Facilities

3.1      The adequacy of the facilities is of equal importance as the technical staff to accomplish the required work
        as specified by this contract. Therefore, the Participant will provide the field and laboratory facilities
        described in this Section.

3.2      Field Facilities

        An adequate cruise vessel to safely traverse the waterways and carry the field crew, field instrumentation,
        sampling equipment, sample preparation equipment and materials, and sample storage facilities.

3.3      Laboratory facilities

        3.3.1    Sample Receipt Area

                Adequate, contamination-free, well ventilated work space provided with chemical resistant bench
                top for receipt and safe handling of CBP samples.

        3.3.2    Storage Area

                Sufficient refrigerator space to maintain unused CBP sample volume for 60 days after data
                submission. NOTE: Samples or extracts and standards shall each be stored separately. Samples
                shall be stored in an atmosphere demonstrated to be free from all potential contaminants.


        3.3.3    Sample Preparation Area

                Adequate, contamination-free, well-ventilated work space provided with:

                3.3.3.1  Benches with chemical resistant tops, exhaust hoods.

                3.3.3.2  Source of distilled or demineralized organic-free water.

                3.3.3.3  Analytical balance(s) located away from drafts and rapid changes in temperature.
                                                  l-ll

-------
                                                                                               Chapter I
                                                                                           Introduction
                                                                                           August 1996
        3.3.4    Standards and reagents

                The Participant will have in-house appropriate standards and reagents to perform the procedures in
                this SOW.
4.       Instrumentation and Equipment

4.1     The Participant will have the field and laboratory instrumentation and equipment described in this Section.

4.2     All equipment and instrumentation specified in this document are recommended and should be in the
        possession of the Participant and in good condition at all times during the length of the grant. The
        Participant will ensure that, in the event of instrument or equipment failure, backup instrumentation or
        equipment in good condition are available to perform field measurements, and sample collection,
        preparation, and analysis.  It is recommended that surge protectors and a temporary backup power supply
        source are installed in order to protect analytical instruments, PCs, and other equipment in the event of a
        temporary electrical disruption or power surge.

4.3     In addition, the Participant should have an in-house stock of instrument parts to ensure continuous
        operation to meet contract-specified holding and turnaround times.

4.4     At a minimum, the Participant should have the following instruments and equipment operative.

        4.4.1    Field Instrumentation and equipment

                4.4.1.1  Secchidisk.

                4.4.1.2  CTD device, equipped with pH probe, DO probe, depth sensor, bottom sensor, light
                        attenuation sensors.

                4.4.1.3  Sample collection bottles.

                4.4.1.4  System to collect below surface samples.

                4.4.1.5  Plankton nets.

                4.4.1.6  Stationary Bongo dropnet.

                4.4.1.7  Diaphragm pump system.

                4.4.1.8  Spade-type coring device.


        4.4.2    Water Quality analyses

        4.4.2.1  Continuous flow automated analytical system equipped with an autosampler, manifold,
                proportional pump, colorimeter, phototube, recorder or computer based data system, and heating
                bath (e.g., Technicon Auto Analyzer).

                4.4.2.2  Nitrogen Analyzer equipped with a combustion tube, reduction tube, water trap, and


                                                  1-12

-------
                                                                                      Chapter I
                                                                                   Introduction
                                                                                   August 1996
                nitrogen detector.

        4.4.2.3  TOC Analyzer which employs high temperature combustion, platinum catalyst, and a
                nondispersive infrared detector.

        4.4.2.4  Air incubator, capable of maintaining 20 + 2« C.

        4.4.2.5  Dissolved oxygen meter and probe.

        4.4.2.6  Centrifuge.

        4.4.2.7  Dual beam spectrophotometer with matched cuvettes.

        4.4.2.8  Drying oven capable of maintaining 104 + 2« C.

        4.4.2.9  Muffle furnace capable of maintaining 550 + 50« C.

        4.4.2.10 pH meter and probe.


4.4.3    Biological analyses

        4.4.3.1  Binocular Dissecting microscopes.

        4.4.3.2  Fiber optic illuminators.

        4.4.3.3  Compound microscopes.

        4.4.3.4  Inverted plankton microscope.

        4.4.3.5  Epifluorescence microscope.

        4.4.3.6  Scintillation counter.

        4.4.3.7  Fluorescently lighted magnifiers.


4.4.4    Data Management and Handling

        4.4.4.1  Hardware and Software - IBM compatible personal computer running DOS 3.1 or 3.3
                with 640K RAM, a 60 megabyte hard disk, an Intel 80286 processor, a 3.5" disk drive, an
                EPSON FX100 or compatible printer, and a 2400 baud modem with PROCOMM. The
                Participant will also have word processing software capable of processing and reading
                ASCII text files.

        4.4.4.2  The Participant will submit reports and data packages as specified in Chapter III of this
                document. Space, tables, and adequate copy machines will be provided to meet the
                requirements of this document.  The Participant will also designate personnel to perform
                tasks specified in the SOW and to use the hardware and  software listed above in the
                performance of such tasks. The laboratory manager shall authorize by signing any data

                                         1-13

-------
                                                              Chapter I
                                                           Introduction
                                                          August 1996
that have been manually edited.
                      1-14

-------
                                                                                 Chapter II
                                                                         Quality Assurance
                                                                               August 1996
                                CHAPTER II
                    QUALITY  ASSURANCE
Section A.      Introduction

Section B.      General Q A/QC Requirements

       1. Reporting
       2. Chain-of-Custody
       3. Participation in Technical Meetings
       4. Procedural Change Authorization

Section C.      Field QA/QC Procedures

       1.  Annual Calibration
       2.  Calibration Check
       3.  Check Sample

Section D.      Laboratory QA/QC Procedures

       1. Method Blank
       2. Matrix Spike
       3. Laboratory Replicate
       4. Check Standard
       5. Glassware Cleaning

Section E.       Data Quality Objectives

       1. General DQOs
       2.  Sampling
       3. Field Measurements
       4. Water Quality Monitoring
       5. Phytoplankton Monitoring
       6. Zooplankton Monitoring
       7. Benthic Monitoring

Section F.       Documentation Recommendations

       1. Quality Assurance Plan
       2. Quality Assurance Project Plans
       3. Standard Operating Procedures
       4. Document Control
       5.  Contingency and Health and Safety Plans
                                            II-1

-------
                                                                                       Chapter II
                                                                               Quality Assurance
                                                                                    August 1996
       Section G.      Performance Assessment

       1. Split Sample Program
       2. Performance Evaluation Samples
       3. Audits of Data Quality
       4. On-Site Audits

Section H.      References
                                               II-2

-------
                                                                                          Chapter II
                                                                                  Quality Assurance
                                                                                        August 1996
                                         SECTION A

                                     INTRODUCTION
The Chesapeake Bay Program (CBP) was established by Congressional directive with the objectives of
characterizing the state of the Chesapeake Bay, identifying long term trends, and providing data and guidance to
managers and modelers during the restoration phase.  The Chesapeake Bay Program Office (CBPO) has developed
and integrated into all phases of the monitoring and measurement activities under its purview a scheme of quality
assurance (QA) practices. These practices, as defined in the CBP QA Program Plan (QAPP), are focused on
ensuring that all data generated through the CBP are scientifically valid, defensible, of known quality, and designed
to meet data user requirements.

A QA program shall be developed and implemented within the participants' organization that is in accordance with
the procedures and recommendations of this document.  The purpose of this chapter is to define the
recommendations of the participants' QA program.  Section B provides an overview of the programmatic QA and
quality control (QC) recommendations. Method-specific QC recommendations are provided within each field
measurement, sampling, and analytical procedure. Section C provides information on the program's Data Quality
Objectives, Section D provides documentation recommendations, Section E provides for initial and continuous
performance assessment, and Section F provides a list of relevant references.
                                                 II-:

-------
                                                                                           Chapter II
                                                                                  Quality Assurance
                                                                                        August 1996
                                         SECTION B

                     GENERAL QA/QC REQUIREMENTS
1.       Reporting

1.1      Field data and laboratory analysis information should be entered into an automated data entry and quality
        assurance program that will be provided by the Chesapeake Bay Program.  This Program will provide a first
        level of statistical range checking, quality control checking and output as recommended by this document.

1.2      Cruise event data collected at the cruise location may be entered on location. Cruise event data points
        relevant to laboratory analysis should be entered using the guidelines as outlined in the CBP Data
        Management Plan (DMP).

1.3      Hardcopy records and source documents for both the cruise event data and the laboratory analysis data
        should be kept for a period of 5 years after the last day of the cruise.

1.4      The CBPCC will provide training for up to  4 employees on the use of the CBP-supplied program, when the
        software is installed.  Henceforth, it will be the responsibility of the Participants to train their staff
        members.

1.5      The Participants shall keep electronic media backups of the cruise data, for the period of the grant. At the
        end of the grant, this data must be relinquished to the CBPO.

1.6      The Participants will submit a Cruise Report at the end of each cruise within approximately two days after
        the end of the cruise.

1.7      The Participants shall submit a complete data package for each cruise. This submission must comprise all
        field measurement, analytical, and all relevant QC data from all stations sampled during the cruise. This
        information must adhere to the requirements outlined in the Data Management Plan (DMP).

1.8      The Participants will be provided with a PC based program that can be utilized for entry, verification, and
        submission of data to the CBPO.

        1.8.1    Data may be entered in one of two ways: using manual data entry screens for each type of data; or
                the program will accept input from another computer or instrument if data are submitted in EPA
                standard format (ESF).

        1.8.2    The program has data entry screens for each type of data.  These screens are used to enter the data.
                While data are being entered, range checks will be run on each item. When an item is out of
                critical or warning range, the user will be notified.

        1.8.3    The program can accept data from another computer via floppy disk that is in ESF format. When
                these data are input, they will be run through range checks as described in item  1.8.2.

        1.8.4    After all data are entered by one of the above methods, the program will  print out a number of
                graphic plots of the data. The Participants will examine the plots, and the laboratory director is

                                                 II-4

-------
                                                                                               Chapter II
                                                                                      Quality Assurance
                                                                                            August 1996

                required to sign each plot indicating that the data have been examined and appear to be correct.

        1.8.5    The program will print out a listing of all values that are above or below warning and critical
                limits. The laboratory director is required to examine this listing and sign that it is correct.

        1.8.6    The program will print out a list of missing values for the cruise. The designated person in charge
                of the laboratory is required to enter a reason for each of the missing values and print out the list.

        1.8.7    The program will write out a disk in accordance to the DMP format that must be submitted to the
                CBPCC.

        1.8.8    The Participant shall provide a cover letter for each  submittal indicating, and not limited to:

                1.8.8.1  Cruise number.

                1.8.8.2  Time period covered by the submitted data.

                1.8.8.3  Type of data, i.e., Mainstem Monitoring.

                1.8.8.4  A synopsis of maj or problems, if any.

                1.8.8.5  A statement of any changes since the last data submission, if any (a restatement of any
                        issues previously recorded on the "Procedure Change Tracking Form" that affect this
                        submission).

                1.8.8.6  A statement indicating Participant willingness to ensure corrections to the data for a
                        period of five years.

1.9     The required submission must include the following:

        1.9.1    The data disk (results, QC data, and data summary file);

        1.9.2    The plots created under section 1.8.4;

        1.9.3    The list of range values created in section 1.8.5;

        1.9.4    The list of missing values created in section 1.8.6; and,

        1.9.5    A cover letter as described in Section 1.8.8.

1.10    The Participants shall be responsible for correcting any errors found by the CBPCC and resubmitting the
        data in the required format to the CBPO. The Participants shall be required to correct any errors found for
        no additional cost for a period of 5 years after sample collection.


2.       Chain-of-Custodv

2.1     Procedures should be established that ensure that samples are properly collected and preserved from the
        time the samples are collected until the corresponding data are submitted to the CBPCC.
                                                   II-5

-------
                                                                                                     Chapter II
                                                                                            Quality Assurance
                                                                                                  August 1996

        2.2     A system for assuring positive identification of samples and documentation of all samples must be
                operational. To ensure sample integrity, chain-of-custody procedures including procedures for sample
                identification, sample receiving, and sample tracking, should be developed and instituted.

                2.2.1    Sample Identification

                        2.2.1.1  To assure traceability of samples while in possession, there should be a specified method
                                for maintaining identification of samples in the field and throughout the laboratory.

                        2.2.1.2  Each sample and sample preparation container should be labeled with a unique identifier
                                that is cross-referenced with the corresponding documentation.

                2.2.2    Sample Receiving

                        2.2.2.1  A sample custodian (and an alternate) responsible for receiving all samples should be
                                designated.

                        2.2.2.2  The condition of the shipping and sample containers should be inspected and documented
                                upon receipt by the sample  custodian or his/her representative.

                        2.2.2.3  The sample custodian or his/her representative should sign and date all forms
                                accompanying the samples  at the time of sample receipt.

                2.2.3    Sample Tracking

                        2.2.3.1  Records documenting all phases of sample handling from collection to final analysis
                                should be maintained.

        3.       Participation in Technical Meetings

        3.1     Attendance of Monitoring Subcommittee meetings, Analytical Methods and Quality Assurance Workgroup
                (AMQAW) meetings, and miscellaneous technical meetings as required, is recommended by the CBPO.

        3.2     The CBP Monitoring Subcommittee coordinates multi-jurisdictional efforts to monitor the Chesapeake Bay
                basin system.  It manages and ensures continued accessibility of the resultant environmental data and
                promotes multi-disciplinary interpretation and reporting of the data on a jurisdiction and program-wide
                basis.  The Monitoring Subcommittee oversees implementation of new and innovative monitoring programs
                (water quality, living resources,  toxics and ecosystem processes) and techniques. It reevaluates existing
                programs to ensure that environmental data necessary to support implementation of a comprehensive
                quality assurance program (as part of components of the various monitoring programs) are collected.
                Emphasis is placed on ensuring collection and management of comparable environmental data of known
                quality through continued communication and transfer of technologies between the agencies and institutions
                involved in the Chesapeake Bay Monitoring Program.

3.3      AMQAW comprises technical advisors to the Monitoring Subcommittee concerning field and analytical methodology and
        quality assurance issues. These advisors  include laboratory directors from the mainstem and tributary laboratories, field
        managers, and State managers conducting work for the Chesapeake Bay Program.  The workgroup's goal is to discuss
        analytical and field protocols, identify discrepancies (the issues are usually identified by reviewing the  data), and take
        measures to improve the situation. The workgroup provides a forum for exchange of technical information focused on
        moving towards standardization of methods/use of comparable methods throughout the Chesapeake Bay Monitoring Program.


                                                          II-6

-------
        The forum allows the different organizations to share the way they do things and individuals to present new and innovative
        ideas, potentially for their use.

3.4     AMQAW reviews issues pertaining to the CBP Coordinated Split Sampling Program (CSSP). As directed by the CBPO and
        AMQAW, the Participants shall conduct follow-up investigations to determine possible causes of inter-organization
        differences in CSSP results.  Funding may be applied for from the Monitoring Subcommittee for special studies to improve
        the quality of field and laboratory methods.


4.       Procedural Change Authorization

4.1     Any substantial or long-term changes to a procedure or method, either in the field or laboratory, should be submitted to the
        CBP Quality Assurance Officer.  These types of changes may include items such as modifications to detection limits,
        instrument type or sampling stations.  All actual and proposed modifications should be documented using the Chesapeake
        Bay Monitoring Program Procedure Modification Tracking Form (PMTF) (Figure II-l).

4.2     The completed PMTF should be submitted to the CBP QAO within 30 days after the last day of the cruise.

4.3     Minor events occurring in the laboratory should be documented in the data summary file, associated with the data in the
        diskette.

4.4     At the conclusion of the cruise, a Monitoring Cruise Report should be completed and submitted to the State agency, who will
        then forward it to the CBPO. The Chesapeake Bay Monitoring Program Cruise Report is shown in Figure II-2.

4.5     Modifications due to emergencies during a sampling cruise are authorized by the Chief Scientist with priorities for safety and
        completion of the cruise. Modifications should be reported after the cruise. Depending on size or amount of impact on the
        data the deviation has, the change should be documented in either the PMTF or the Monitoring Cruise Report.

-------
                                                          Figure II-1
CHESAPEAKE BAY MONITORING PROGRAM
PROCEDURE MODIFICATION TRACKING FORM
PMTF#
                                                                                                         APPROVED
                                                                                                                        DENIED
         This form is used to request approval for modifications and to document approved modifications made to Chesapeake Bay Program Office
         procedures or methods.  It is not a substitute for timely contact with the CBPO Quality Assurance Officer or his/her designee, who may be
         reached at 1-800-523-2281. A detailed method description including the proposed modification must be attached to this form prior to submittal to
         CBPO.
DATE SUBMITTED DATE APPROVED
REQUESTOR NAME ORGANIZATION
NEWLY PROPOSED [] FIELD - APPRO VED [ ] APPROVED BY:
MODIFICATION MODIFICATION DATE:
TYPE OF
PROCEDURE/METHOD
DURATION
PROCEDURE/METHOD
DESCRIPTION
MODIFICATION
DESCRIPTION
JUSTIFICATION FOR
MODIFICATION
ANALYTICAL
PARAMETERS THAT MAY
BE AFFECTED BY THIS
CHANGE
AFFECTED QA PLAN(S)
(INCLUDE TITLE,
REVISION, AND DATE)
AFFECTED CRUISE(S)
PMTF COMPLETED BY
SAMPLING [ ] ANALYTICAL [ ] REPORTING [ ]
FIELD [ ] OTHER [ ]
MEASUREMENT SPECIFY:
PERMANENT [ ] EFFECTIVE DATE:
TEMPORARY [ ] START DATE:
END DATE:






NAME: DATE:
    STATE APPROVAL: NAME
    SIGNATURE
    CBPO APPROVAL:
                              NAME
                                                         DATE
                              SIGNATURE
                                                                          TITLE
                                                                                   TITLE.

                                                                                   DATE

-------
                                                                                        Chapter II
                                                                                Quality Assurance
                                                                                     August 1996
                                        SECTION C

             FIELD QUALITY ASSURANCE PROCEDURES
1.       Annual Calibration

1.1      An annual calibration is an extensive and thorough calibration using standards or instruments relating back
        to certified (e.g. National Institute of Standards and Technologies) instruments or standards to ensure the
        parameter precision.

1.2      These calibrations will be performed on each instrument at least annually.

2.       Calibration Check

2.1      A calibration check is a verification performed before and after each cruise to ensure that the instrument
        response is comparable that which existed at the annual calibration.

2.2      Calibration checks are performed before and after each cruise.

2.3      Calibration by standard operating procedures should include measurements against a reference standard or
        meter.

2.4      When the calibration check indicates a significant change during a cruise, the instrument should be re-
        calibrated as described in the annual calibration.

3.       Check Sample

3.1      A check sample is a water sample that is collected simultaneously with an in-situ measurement and returned
        to the laboratory for analysis.
                                               II-9

-------
                                                                                        Chapter II
                                                                                Quality Assurance
                                                                                     August 1996
                                        SECTION D
      LABORATORY QUALITY ASSURANCE PROCEDURES

1.      Method Blank

1.1     A method blank is a volume of ASTM Type II reagent grade water that is carried through the entire
       analytical procedure.  The purpose of a method blank is to determine the levels of contamination
       associated with the processing and analysis of samples.

1.2     A method blank should be analyzed once for every 10 CBP samples (preferable), however every 20
       samples is acceptable for those instances where the concentrations are low and this is the total sample
       number.

1.3     If the concentration of analyte exceeds the MDL, laboratory or reagent contamination should be suspected.
       If the analyte concentration is 5 times the MDL or greater, then corrective action is required and reanalysis
       if possible.

2.      Matrix Spike (not required for chlorophyll, PHOSP, TSS, PC and PN)

2.1     A matrix spike is used primarily as a means of evaluating bias that may result from the analysis of a
       particular matrix when using a specific procedure. The saline, aqueous matrix has been demonstrated to
       impart bias in some analyses.  Sample spike analysis involves the introduction of a know amount of the
       analyte of interest into one of two aliquots from a well homogenized sample and a calculation of spike
       recovery.

2.2     The spike concentration must be greater than the original or background concentration of the sample and
       not less than four times the calculated MDL.

2.3     The sample is spiked prior to all steps in the analytical process, particularly when a digestion is involved.

2.4     Proper assessment requires that the integrity of the sample matrix be maintained. The original sample must
       not be diluted more than 10% due to the spike process.


2.5     The analytical system response from the sample plus the spike should be in the same range as the sample
       set undergoing analysis, ideally approximating 50-75% of a full scale response.

2.6     A matrix spike should be analyzed once for every 10 CBP samples.

2.7     Matrix spikes can not be performed on lab or field blanks.
                                               11-10

-------
                                                                                              Chapter II
                                                                                     Quality Assurance
                                                                                           August 1996

2.8     The percent recovery of analyte from the matrix spike sample is calculated using the following equation:

                                                          oon   on
                              Matrix Spike Recovery = - x 100
                where,

                        SSR =  Spike sample result
                        SR  = Sample result
                        SA  = Spike added

2.9     If the spike recovery is outside the range designated in Table II.3, the spike analysis is repeated after
        checking for obvious sources of error.  At a minimum, this involves an immediate repeat of the
        instrumental analysis.  If the result is still beyond acceptance limits, and the analytical process employed a
        digestion step, the matrix spike should be reanalyzed including redigestion. If the recovery of the replicated
        sample spike continues to remain outside the designated range, the recover problem is judged to be matrix
        related.  It is considered a non-system problem, requiring no further corrective action.

2.10    The recovery of a matrix spike should be reported with the concentrations of the background sample and
        the known, theoretical spike.

3.       Laboratory Replicates

3 . 1     Laboratory replicate analyses provide a measure of laboratory precision.  Duplicates are prepared by taking
        two aliquots for analysis from a well homogenized sample.  More replicates may be analyzed and reported.

3.2     A laboratory replicate should be analyzed once for every 10-20 CBP samples preferably, however every 20
        samples is acceptable for those instances where the concentrations are low and this is the total sample
        number.
                                     SD
                                  MEAN
                                                               •   i     '

3.3     The precision is measured by calculating the coefficient of variation (CV) using the following equation:
                where,
                        CV  = Coefficient of variation
                        SD  = Standard deviation
                        Mean = Mean of the replicate readings
                        N  = Number of samples

3.4     If the CV does not fall within the range in Table II.3, corrective action should be taken.
                                                  11-11

-------
                                                                                             Chapter II
                                                                                    Quality Assurance
                                                                                          August 1996
4.       Check Standard
4.1      An accurately prepared chemical standard is analyzed every 10 CBP samples preferably, however every 20
        samples is acceptable for those instances where the concentrations are low and this is the total sample
        number. The results are compared to the known analyte concentration.  If the determined concentration for
        known analysis is not within 90-110% of the known analyte concentration, a second check standard is
        prepared and analyzed  to confirm or deny the initial "out of control" analysis. If the reanalyzed check
        standard is within acceptance limits, sample analysis proceeds; however, if the reanalyzed check standard
        fails the acceptable limits, the instrument must be recalibrated. All the samples between that check standard
        and the previous standard must be reanalyzed.


5. Glassware Cleaning

5.1      Standard and Reagent Glassware should be rinsed with 10% HC1 once and then rinsed 3 times with reagent
        grade water.

5.2      Sample Containers should be rinsed with tap water, 10% HC1 and then rinsed 4 times with reagent water.
        Then, before use they should be rinsed 3 times with sample.

5.3      AutoAnalyzer Cups should be rinsed three times with the sample, and then filled.
                                                 11-12

-------
                                                                                            Chapter II
                                                                                   Quality Assurance
                                                                                         August 1996
                                          SECTION E

                    DATA QUALITY OBJECTIVES  (DQO)
1.       General DQOs

1.1      Data Quality Objectives are qualitative and quantitative statements that specify the quality of data required
        to support specific CBPO decisions. DQOs also specify the level of uncertainty that a decision maker is
        willing to accept in results derived from monitoring data, when the results are used in a regulatory or
        programmatic decision, such as establishing analytical method requirements, establishing sampling
        protocols, and revision or development of industry standards.

1.2      The DQOs defined in this Section were developed by the CBPO using existing performance information on
        the methods and procedures contained in this document. DQOs are established through an iterative process,
        these values may be adjusted by the CBP QAO as a result of evaluations of performance data generated
        during this program.

1.3      The main objective of this document is to provide monitoring data of known and consistent quality to the
        CBPO. This data will be used in characterizing the state of the Chesapeake Bay, identifying long term
        trends, and providing data and guidance to managers and modelers during the restoration phase.

1.4      The domain of concern for the Chesapeake Bay Monitoring Program comprises the chemical and biological
        characterization of the waters and sediment of the Chesapeake Bay and its tributaries.

1.5      The levels of quality of sampling activities are expressed in terms of comparability, representativeness,
        precision, accuracy, and completeness using the following criteria.

        1.5.1   Following the sampling procedures and sample locations recommended in this document may
               ensure sampling comparability and representativeness of data generated to meet the CBP needs.

        1.5.2   Overall precision (sampling and analytical) is assessed through field replicate
               measurements/analyses, and is expressed as coefficient of variation (CV). Sampling precision can
               be evaluated by comparing overall precision to measurement/analytical precision.

        1.5.3   Overall accuracy is assessed through field spike analyses, and is expressed as percent recovery.
               Sampling accuracy can be evaluated by comparing overall accuracy to measurement/analytical
               accuracy. However, these are not recommended.

        1.5.4   Sampling completeness is calculated based on the ratio of samples collected to samples that were
               planned, and is expressed as percent completeness.

1.6      The levels of quality of measurement and analytical data are expressed in terms of comparability,
        representativeness, precision, accuracy, completeness, and method detection limits (MDL) using the
        following criteria.

        1.6.1   Measurement/analytical comparability and representativeness of data generated will be ensured
               through adherence  to the measurement and analytical procedures described methods document.

                                                11-13

-------
                                                                                              Chapter II
                                                                                     Quality Assurance
                                                                                           August 1996


        1.6.2    Precision, expressed as coefficient of variation (CV), for measurement and analytical data is
                calculated based on replicate measurements/analyses.

        1.6.3    Accuracy, expressed as percent of reference value, of measurement data is calculated based on
                measurements of standard reference materials (where available) and calibrating reference
                techniques.

        1.6.4    Accuracy, expressed as percent recovery, of analytical data is calculated based on the analysis of
                spiked samples and reference materials.

        1.6.5    Completeness of measurement data is calculated based on the ratio of measurements made to
                measurements planned, and is expressed as percent completeness.

        1.6.6    Completeness of analytical data is calculated based on the ratio of samples that are analyzed to the
                number of samples collected, and is expressed as percent completeness.

        1.6.7    Method detection limits should be determined for all parameters using the procedures
                recommended by the AMQAW as described below.

                1.6.7.1  Samples used in the determination of MDLs should be environmental samples collected
                        once each year during winter, or whenever that analyte's concentration is lowest for the
                        year. The sampling location most appropriate and representative for MDL analyses
                        should be determined before collection.

                1.6.7.2  MDL values should be determined as 3 times the standard deviation of seven replicate
                        measurements/analyses of the same sample.

                1.6.7.3  MDLs  should be verified for each parameter on an annual basis or whenever a change is
                        made in the measurement or analytical methodology.

                1.6.1 A  A table of MDLs values and all supporting documentation should be maintained by the
                        Participant and made available for review as requested by a CBPO representative. When
                        values  change, the revised table of MDL values should be included with each data
                        package.

1.7      Real-time quality control charts for precision and accuracy should be developed and maintained for each
        parameter and each concentration level, using the most recent 25  points, at least. More points may be used
        if deemed necessary.  The CBPO will provide further information on a PC-based software package to
        facilitate the calculations and to ensure consistency in the development of the control charts.

        1.7.1    Control charts are centered at the arithmetic mean. Unless otherwise specified in the method, the
                upper and lower control limits are defined at + 3 standard deviations from the mean and the upper
                and lower warning limits are defined at + 2 standard deviations from the mean.
        1.7.2    Precision and accuracy acceptance windows for implementation during the development phase of
                the control charts are provided within each method and in Sections 2, 3, 4, 5, and 7.

        1.7.3    Once control charts have been established, they should be used to determine if a  given analytical
                or measurement process is in control.
                                                  11-14

-------
                                                                               Chapter II
                                                                      Quality Assurance
                                                                            August 1996

1.7.3.1  A process is out of control if 3 or more data points are outside either control limit.

1.7.3.2  Immediate corrective action is recommended for any process identified as being out of
        normal control limits.  Where possible, this should include reanalysis.

1.7.3.3  A warning of possible systematic error is indicated if 7 successive data points fall away
        from the mean on the same side of the center line, if 7  or more data points fall outside of
        either warning limit, or if a discernible trend develops.
                                  11-15

-------
                                                                                           Chapter II
                                                                                  Quality Assurance
                                                                                        August 1996
2.       Sampling

2.1      Sampling precision, accuracy, and completeness objectives are provided in Table II. 1.

                               Table II. 1  Sampling Data Quality Objectives
PARAMETERS
Water Quality
Phytoplankton
Zooplankton
Benthic
REFERENCE
IV.C.3
IV.C.4
IV.C.4
IV.C.4
PRECISION
< 20%
< 20%
< 20%
< 20%
ACCURACY
80 -120%
80 -120%
80 -120%
80 -120%
COMPLETENESS
90%
90%
90%
90%
3.       Field Measurements

3.1      Precision, accuracy, completeness, and MDL objectives for field measurements are provided in Table II.2.

                               Table II.2 Objectives for Field Measurements
PARAMETER
PH
D.O.
Secchi Depth
Specific
Conductance
Salinity
Light
Attenuation
Water
Temperature
Depth
REFERENCE
IV.C.2.4
IV.C.2.4
IV.C.2.3
IV.C.2.4
IV.C.2.4
IV.C.2.4
IV.C.2.4
IV.C.2.4
PRECISION
< 20%
< 20%
< 20%
< 20%
< 20%
< 20%
< 20%
< 20%
ACCURACY
80 - 120
80 - 120
80 - 120
80 - 120
80 - 120
80 - 120
80 - 120
80 - 120
COMPLETENESS
90%
90%
90%
90%
90%
90%
90%
90%
MDL
0.1 pH
0.2 mg
DO/L
O.lm
1 umho/cm
0.1 ppt
0.05% @
100% light
0.1-C
1.0m
                                                11-16

-------
                                                                                          Chapter II
                                                                                  Quality Assurance
                                                                                        August 1996
4.       Water Quality Monitoring
4.1      Precision, accuracy, completeness, and MDL objectives for water quality analyses are provided in Table
        II.3.
                             Table II.3 Objectives for Water Quality Analyses
PARAMETER
Total Dissolved
Phosphorus
Dissolved
Ortho
Phosphate
Paniculate
Phosphorus
Nitrite
Nitrite +
Nitrate
Ammonia
Total
Dissolved
Nitrogen
Paniculate
Nitrogen
Paniculate
Carbon
Dissolved
Organic Carbon
Chlorophyll
Total Suspended
Solids
Silicates
REFERENCE
IV.D.2
IV.D.3
IV.D.4
IV.D.5
IV.D.6
IV.D.7
IV.D.8
IV.D.9
IV.D.10
IV.D.ll
IV.D.13
IV.D.14
IV.D.16
PRECISION
< 20% CV
< 20% CV
< 20% CV
< 20% CV
< 20% CV
< 20% CV
< 20% CV
< 20% CV
< 20% CV
< 20% CV
< 20% CV
< 20% CV
< 20% CV
ACCURACY
80 - 120%
Recovery
80 - 120%
Recovery
N/A
80 - 120%
Recovery
80 - 120%
Recovery
80 - 120%
Recovery
80 - 120%
Recovery
N/A
N/A
80 - 120%
Recovery
N/A
N/A
80 - 120%
Recovery
COMPLETENESS
90%
90%
90%
90%
90%
90%
90%
90%
90%
90%
90%
90%
90%
MDL
O.OOlmg
TDP/L
0.0006mg
PO4F/L
0.00 12mg
PP/L
0.0002mg
NO2/L
0.0002mg
NO2+3/L
0.004mg
NH4/L
0.026mg
TDN/L
0.019mg
PN/L
0.097mg
PC/L
0.5mg
DOC/L
0.2- g
Chla/L
2mg
TSS/L
O.OlSmg
Si/L
                                                11-17

-------
                                                                                            Chapter II
                                                                                   Quality Assurance
                                                                                         August 1996


5.       Phytoplankton Monitoring

5.1      Precision, accuracy, and completeness objectives for phytoplankton analyses are provided in Table II.4.


                             Table II.4 Objectives for Phytoplankton Analyses
PARAMETER
Phytoplankton
Enumeration
Phytoplankton
Identification
Phytoplankton
Biomass
Picoplankton
Enumeration
Picoplankton
Identification
Picoplankton
Biomass
Productivity
REFERENCE
V.D.3.3
V.D.3.3
V.D.3.4
V.D.4.3
V.D.4.3
V.D.4.4
V.D.5
PRECISION
< 20%
< 10%

< 20%
< 10%


ACCURACY
< 20%
< 10%

< 20%
< 10%


COMPLETENESS
95%
90%
90%
95%
90%
90%
90%
6.       Zooplankton Monitoring

6.1      Precision, accuracy, and completeness objectives for Zooplankton analyses are provided in Table II.5.

                              Table II.5  Objectives for Zooplankton Analyses
PARAMETER
Enumeration
Identification
Biomass
REFERENCE
VI.D.3.3
VI.D.3.3
VI.D.3.4
PRECISION
<5%
< 10%

ACCURACY
<5%
< 10%

COMPLETENESS
95%
90%
90%
                                                 11-18

-------
                                                                                          Chapter II
                                                                                 Quality Assurance
                                                                                       August 1996
7.       Benthic Monitoring

7.1      Precision, accuracy, and completeness objectives for benthic analyses are provided in Table II.6.

                                Table II.6 Objectives for Benthic Analyses
PARAMETER
Macrofauna
Sorting
Macrofauna
Enumeration
Macrofauna
Identification
Macrofauna
Biomass
Sediment
Particle Size
Sediment
Organic
Content
REFERENCE
VTLD.3.3
VTLD.3.4
VTLD.3.4
VTLD.3.5
VTLD.4.4
VTLD.4.5
PRECISION
<5%
<5%
<5%



ACCURACY
<5%
<5%
<5%



COMPLETENESS
90%
90%
90%
90%
90%
90%
                                                11-19

-------
                                                                                           Chapter II
                                                                                   Quality Assurance
                                                                                         August 1996


                                          SECTION F


                DOCUMENTATION RECOMMENDATIONS



1.       Quality Assurance Plan (QAP)

        A QA program with the objective of providing sound monitoring data should be developed and
        implemented.  This program should include the specific procedures for identifying out of control sampling,
        field measurement, and analytical conditions and implementing and documenting the necessary corrective
        actions, the mechanisms for the accurate and timely preparation of required documentation, as well as the
        quality assessment measures performed by management to ensure acceptable data production.

1.1      As evidence of such a program, a written Quality Assurance Plan (QAP) which describes the procedures
        that are implemented in the field and the laboratory should be prepared to achieve the following:

        1.1.1    Maintain data integrity, validity, and usability.

        1.1.2    Ensure that sampling and analytical systems are maintained in an acceptable state of stability and
                reproducibility.

        1.1.3    Detect problems through data assessment and establish corrective action procedures to ensure that
                the sampling, analytical, and measurement processes are reliable.

        1.1.4    Document all aspects of the sampling, analytical, and measurement processes in order to provide
                data that are technically sound and legally defensible.

1.2      The QAP should present, in specific terms, the policies, organization, objectives, and specific QA and QC
        activities designed to achieve the data quality requirements recommended in this document.  Where
        applicable, Standard Operating Procedures pertaining to each element should be included or referenced as
        part of the QAP.  The QAP should be available during on-site laboratory evaluations. Additional
        information relevant to the preparation of a QAP can be found in EPA and ASTM publications.

1.3      The following outline identifies the key elements that should be included in the QAP.
                                                11-20

-------
                                                                          Chapter II
                                                                  Quality Assurance
                                                                        August 1996
I       QA Policy and Objectives

II       Organization and Personnel
               QA Management
                       Organization
                       Assignment of QA and QC Responsibilities
                       Reporting Relationships

               Personnel
                       Education and Experience Qualifications Pertinent to this document
                       Training Program
III      Facilities and Equipment
               Equipment, Instrumentation, and Backup Alternatives
               Maintenance Activities and Schedules
               Materials and Supplies
IV      Document Control
               Field and Laboratory Notebook Policy
               Sample and Data Tracking/Custody Procedures and Documentation
               Requirements
               Logbook Maintenance and Archiving Procedures
               Data Package Organization, Preparation, and Review Procedures
               Procedures for Preparation, Approval, Review, Revision, and Distribution of
               SOPs
V      Field QA/QC
               Field Equipment Maintenance, Calibration, and Operation
               Field Measurements
               Sample Collection
               Sample Handling, Preservation, and Shipping
VI      Analytical QA/QC
               Calibration Procedures and Frequency
               Sample Handling and Storage Procedures
               Sample Preparation Procedures
VII     Data Generation
               Data Collection Procedures
               Data Reduction Procedures
               Data Review Procedures
               Data Reporting and Authorization Procedures
               Data Management Procedures


                                11-21

-------
                                                                                             Chapter II
                                                                                    Quality Assurance
                                                                                          August 1996


                VIII    Quality Assurance Program Assessment

                        •       Data Audits
                        •       Systems Audits
                        •       Performance Audits
                        •       Corrective Action System
                        •       QA Reporting Procedures


1.4     The Participant's QAP should be submitted to the CBPO within 30 days after grant award. The QAP
        should be revised based on any comments from the State Agency, EPA Project Officer or EPA QAO.

1.5     The revised QAP must include changes resulting from any of the following evaluations:

        1.5.1    The Participant's internal review of their organization, personnel, facility, equipment, policy, and
                procedures.

        1.5.2    The Participant's implementation of the requirements of the grant.

        1.5.3    The CBPO's review of the laboratory evaluation sample data, bidder supplied documentation.

        1.5.4    Recommendations made during the pre-award laboratory evaluation.

1.6     During the term of grant, the Participant shall amend the QAP when the following circumstances occur:

        1.6.1            The grant is modified.

        1.6.2            There are deficiencies in the QAP document.

        1.6.3            There are deficiencies resulting from the CBPO's review of their QAP document.

        1.6.4            Deficiencies resulting from their internal review of their QAP document are identified.

        1.6.5            The Participant's organization, personnel, facility, equipment, policy, and/or procedures
                        change, and/or

        1.6.6            The Participant identifies deficiencies resulting from the internal review of their
                        organization, personnel, facility, equipment, policy, or procedures.

1.7     The Participant will amend the QAP within 30 days of when the circumstances listed above result in a
        discrepancy between what was previously described in the QAP and what is presently occurring at the
        facility.

Note: The date any changes occurred shall be included as part of the amendment with a reference to the old
document.
                                                 11-22

-------
                                                                                            Chapter II
                                                                                   Quality Assurance
                                                                                         August 1996
2.       Quality Assurance Project Plans
2.1      The Chesapeake Bay Quality Assurance Program requires the development and implementation of a Quality
        Assurance Project Plan (QAPjP) for each of its monitoring activities.  The QAPjPs shall address specific
        activities to be performed and procedures to be used by the Participant.

2.2      The major goals of the QAPjPs are (1) to ensure that the level of needed data quality will be determined and
        stated before the data collection efforts begin, and (2) to ensure that all monitoring data generated and
        processed will reflect the quality and integrity established by the QAPjPs.

2.3      The QA Project Plans shall include all information covered by the sixteen points required by QAMS-005/80
        (listed below).

                        Title Page ~ with provision for approval signatures
                        Table of Contents
                        Project Description
                        Project Organization and Responsibilities
                        QA Objectives for Measurement Data
                        Sampling Procedures
                        Sample Custody
                        Calibration Procedures and Frequency
                        Analytical Procedures
                        Internal Quality  Control Checks
                        Performance and Systems Audits
                        Preventive Maintenance
                        Data Reduction, Validation, and Reporting Procedures ~ including specific procedures for
                        assessing data precision, accuracy, completeness, representativeness, and comparability.
                        Data Review Procedures and Criteria
                        Corrective Actions
                        Quality Assurance Reports to Management

2.4      Review and Approval of QAPjPs

        2.4.1    The CBPO (EPA PO and QAO) and the State agency will review all QAPjPs at least to the
                "Conditional Approval Recommended" level (all technical issues having been resolved to the
                satisfaction of the CBPO  and VADEQ) prior to data collection.  The QAPjPs shall be reviewed and
                approved in the context of the Program's DQOs.

        2.4.2    The CBP QAO shall review and evaluate the implementation of the plans during the operational phase
                of the monitoring activity. The CBP QAO shall also assess the actual performance of the planned
                activity and subsequent results according to the criteria described in the QAPjPs.

3.       Standard Operating Procedures

3.1      In order to obtain reliable results, adherence to recommended methodology is important.  In any operation that
        is performed on a repetitive basis,  reproducibility is best accomplished through the use of Standard Operating
        Procedures (SOPs). An SOP is a written document which provides directions for the step-by-step execution of
        an operation, test, or action which  is commonly accepted as the method for performing certain routine or
        repetitive tasks.  These tasks include such operations as sampling, sample tracking, analysis, glassware
        preparation, instrument calibrations, preventive and corrective maintenance, and data reduction and analysis.


                                                 11-23

-------
                                                                                              Chapter II
                                                                                     Quality Assurance
                                                                                           August 1996

        SOPs should be expressed in terms of fixed protocols which must be followed. Where options exist, these
        should be clearly described, and criteria for the selection of alternatives must be included. The SOPs should be
        written such that the actual practices are recorded. SOPs should be prepared in document control format and
        should be submitted to the CBP QAO for reference purposes.

3.2     SOPs should be clear, comprehensive, up-to-date, and sufficiently detailed to permit duplication of results by
        qualified analysts. All SOPs should reflect activities as they are currently performed in the field and
        laboratory.  In addition, all SOPs should be:

        3.2.1    Adequate to establish traceability of standards,  instrumentation, samples, and monitoring data.

        3.2.2    Simple, so that any user with appropriate general education, experience, and training can duplicate the
                task as historically performed.

        3.2.3    Complete enough so the user or auditor follows the directions in a logical step-wise manner through
                the sampling, analysis, and data handling processes.

        3.2.4    Consistent with sound scientific and engineering principles.

        3.2.5    Consistent with applicable federal and state regulations and guidelines.

        3.2.6    Consistent with the instrument manufacturers' specific instruction manuals.

        3.2.7    Consistent with the recommendations of methods consensus workshops approved by the Monitoring
                Subcommittee.

        3.2.8 Consistent with good laboratory practices.

3.3     Benefits of SOPs

        3.3.1    Provide a record of the performance of all tasks at any fixed point in time.

        3.3.2    Increase the opportunity for thorough review of procedures with appropriate sign-off by management.

        3.3.3    Serve as a training document for new employees providing consistent performance of tasks.

3.4     All environmental monitoring should meet established federal and state regulations and guidelines as well as
        comply with the program consensus decisions once confirmed by the Monitoring Subcommittee. Deviations
        should be justified, documented, and approved by the CBP QAO and Monitoring Coordinator. The degree of
        adherence to the approved SOPs should be determined during systems audits. Annually, all SOPS should be
        reviewed by the user, approved by his/her supervisor, and submitted for review of changes to the CBP QAO
        and Monitoring Coordinator.

3.5     The format for SOPs may vary depending upon the kind of activity for which they are prepared. However, at a
        minimum, the following sections must be included:

                •       Title page
                •       Scope and application
                •       Definitions
                •       Procedures


                                                  11-24

-------
                                                                                              Chapter II
                                                                                     Quality Assurance
                                                                                           August 1996

                •       QC limits
                •       Internal review procedures, including procedures for secondary review of information being
                        generated
                •       Corrective action procedures
                •       Documentation description and example forms
                •       Miscellaneous notes and precautions
                •       References

3.6     A typical SOP should include detailed procedures on the following topics, as they apply:

                        Specific sampling site selection
                        Sampling methodology
                        Analytical methodology; flow charts
                        Special precautions and requirements, such as holding times and preservation; interferences
                        State and Federal reference, equivalent, and alternate test procedures
                        Instrumentation selection and use
                        Calibration and standardization
                        Preventive and remedial maintenance
                        Replicate sampling and analysis
                        Blind and spiked samples
                        Quality control procedures such as inter- and intra-laboratory or field activities
                        Split sample protocols
                        Documentation, sample custody, transportation, and handling procedures
                        Sample custody and handling procedures
                        Sample transportation
                        Data management and evaluation procedures; calculations
                        Service contracts
                        Specific quantitative determinations of precision, accuracy, completeness, representativeness,
                        and comparability
                        Document control
                        Safety
                        References
4.       Document Control

4.1     The goal of the document control program is to assure that all documents and electronically stored information
        from a specified cruise are accountable, secure, and completely retrievable. Document control is recommended
        for each activity to include electronic as well as hardcopy documentation. Accountable documents should
        include but not be limited to field and laboratory logbooks, chain-of-custody records, sample work sheets,
        bench sheets, and other documents relating to the sample or sample analyses. The following document control
        procedures have been established to assure that all field and laboratory records are assembled and stored for
        delivery to the CBPO or are available upon request from the CBPO prior to the delivery schedule.

4.2.     Preprinted Forms and Logbooks

        4.2.1    All documents produced which are directly related to the sampling, preparation, and analysis of CBPO
                samples should be maintained for inspection by the CBPO. All observations and results recorded by
                field and laboratory staff but not on preprinted forms should be entered into permanent logbooks.
                When all data from a cruise are compiled, all original field and laboratory forms and copies of all
                                                  11-25

-------
                                                                                               Chapter II
                                                                                      Quality Assurance
                                                                                            August 1996

                cruise-related logbook entries should be included in the documentation package.

        4.2.2    Pre-printed field and laboratory forms should contain the name of the field crew/laboratory and be
                dated (month/day/year) and signed by the person responsible for performing the activity at the time an
                activity is performed.

        4.2.3    Logbook entries should be dated (month/day/year) and signed by the person responsible for
                performing the activity at the time an activity is performed.

        4.2.4    Logbook entries should be in chronological order.

        4.2.5    Pages in both bound and unbound logbooks should be sequentially numbered.

        4.2.6    Data sheets or logs should be maintained to enable a reconstruction of the sample collection or
                analysis in question.

        4.2.7    Corrections to supporting documents and raw data should be made by drawing a single line through
                the error and entering the correct information.  Corrections and additions to supporting documents and
                raw data should be dated and initialed. No information should be obliterated or rendered unreadable.
                All notations should be recorded in ink. Unused portions of documents shall be crossed out.

4.3     Consistency of Documentation

        4.3.1    A document control officer responsible for the organization and assembly of the data package should
                be assigned.

        4.3.2    All copies of field and laboratory documents should be complete and legible.

        4.3.3    Before releasing test results, the document control officer should assemble and cross-check the
                information on sample tags, custody records, laboratory bench sheets, personnel and instrument logs,
                and other  relevant data to ensure that data pertaining to each particular  sample or sample delivery
                group is consistent throughout the data package.

        4.3.4    All documents relevant to each cruise, including logbook pages, bench sheets, screening records, re-
                preparation records, records of failed or attempted tests, and custody records should be inventoried.

4.4     Storage of Files

        4.4.1    Field and  laboratory documents will be maintained in a secure location for a period of five years from
                the date of sample delivery.


5.       Contingency and Health and Safety Plans

5.1     The Participant should develop and implement the following additional plans:

        5.1.1    A contingency plan covering the availability and/or plan for a backup vessel.

        5.1.2    A contingency plan for key field instrumentation failure.
                                                  11-26

-------
                                                                                           Chapter II
                                                                                   Quality Assurance
                                                                                         August 1996

        5.1.3    A Health and Safety Plan in accordance with all applicable State and Federal regulations.

                                           SECTION  G


                         PERFORMANCE ASSESSMENT



1.       Split Sample Program

1.1      Background and Objectives

        The Chesapeake Bay Coordinated Split Sample Program (CSSP) was established in June 1989 by
        recommendation of AMQAW, to the Monitoring Subcommittee. The major objective of this program is to
        establish a measure of comparability between sampling and analytical operations for water quality monitoring
        basin-wide. A secondary objective is to evaluate the in-matrix dilution of standard EPA reference materials.
        These standard reference materials are analyzed in appropriate matrix, fresh to saline, and concentration level
        to match the sample.  All laboratories participating in basin-wide data collection programs are also required to
        participate in the CSSP.

1.2      Summary of Criteria

        1.2.1    The Participant will participate in the applicable component(s) of the CSSP.

        1.2.2    The SOPs that are developed and used should be in accordance with the Chesapeake Bay Coordinated
                Split Sample Program Implementation Guidelines CBP/TRS 58/91, May 1991  plus any revisions
                specified by the CBP QAO.

        1.2.3    For each of the Virginia and Maryland CSSP stations and on a quarterly basis,  the Participant will
                receive and analyze three sub-samples.  Treating each sub-sample as a discrete sample, participating
                laboratories  are generally required to perform only those analyses which they routinely perform in
                support of basin-wide data  collection programs. One of the three sub-samples  should be used to
                generate laboratory duplicates and a laboratory spike. These QC samples should be analyzed
                concurrently with the associated CSSP sub-samples.

        1.2.4    The routine submission of split sample data is the  responsibility of each laboratory and its in-house
                data management organization.

        1.2.5    To supplement the analyses of the three sub-samples and the respective QC sample, EPA standard
                reference material (SRM) for each parameter should be analyzed where available. The analysis of
                standard reference materials provides a strong measure of comparability between all laboratories and
                within one laboratory's analytical system over time. Quarterly analysis of SPJVIs is the most
                independent evaluation of laboratory performance available at this time.  It is a critical element of any
                diagnostic efforts associated with the CSSP.
                                                11-27

-------
                                                                                               Chapter II
                                                                                      Quality Assurance
                                                                                            August 1996
2.       Performance Evaluation Samples
2.1     Performance evaluation (PE) samples are distributed annually to the laboratories participating in the Mainstem
        Monitoring Program for Water Quality. Where available, EPA audit samples for nutrient and demand
        parameters, as well as solids are distributed. An effort is made to adjust PE sample preparation instructions to
        allow analysis in low concentration ranges more appropriate to the program's ambient monitoring levels.


3.       Audits of Data Quality

3.1     Field blank and field duplicate data will be reviewed in order to assess the quality of sampling activities.

3.2     Analytical and measurement data should be reviewed in order to assess the quality of measurement and
        analytical activities, respectively.

3.3     The CBP-provided software will electronically verify the data quality for every submittal or the data review
        criteria will be implemented.

3.4     The Participant will prepare and submit a summary with each data set. The summary must include an
        explanation for each data point that did not meet the QC criteria established for each method, and deviations
        that occurred during the generation of the data.

3.5     The Participant will be informed if any of the submitted data do not fall within the prescribed QC limits. Any
        errors found will be corrected by the Participant at no additional cost to the CBPO.

3.6     The CBP Grant Project Officer has the ultimate responsibility to accept or reject each data submittal.


4.       On-Site Audits

4.1     The CBP QAO will conduct annual on-site evaluations of field and laboratory activities. The frequency of
        these on-site audits may be  increased depending on the Participant's performance. On-site evaluations are
        carried out to monitor their  ability to collect and analyze samples according to the DQOs established by the
        CBP Monitoring Program.

4.2     The CBP QAO and a State representative will inspect the Participant's field and laboratory facilities to verify
        the adequacy and maintenance of instrumentation, the continuity of personnel meeting experience and/or
        education requirements, and the acceptable performance of analytical and QC procedures. The Participant
        should expect that items to be monitored will include but not be limited to the following:


                        Size and appearance of the facility.
                        Quantity,  condition, availability, and scheduled maintenance and performance of
                        instrumentation.
                        Availability, appropriateness, and use of field and laboratory SOPs.
                        Field and  laboratory staff qualifications,  experience, and personnel training programs.
                        Reagents  and sample storage facilities.
                        Reagent and test solutions preparation logbooks and raw data.
                        Field and  laboratory bench sheet and logbook maintenance and review.
                        Review of the sample analysis/data package inspection procedures.


                                                  11-28

-------
                                                                                               Chapter II
                                                                                      Quality Assurance
                                                                                            August 1996


4.3     Prior to an on-site evaluation, various documentation pertaining to performance of the specific Participant is
        integrated in a profile package for discussion during the evaluation. Items that may be included are previous
        on-site reports, laboratory evaluation sample scores, review of data, QA materials, and data trend reports.

4.4     The CBP QAO will discuss his/her findings with the Participant in the presence of a representative from the
        State agency.  During the debriefing, the auditor will present his/her findings and recommendations for
        corrective actions to field and laboratory personnel.

4.5     Following an on-site evaluation, audit reports which discuss deficiencies found during the on-site evaluation
        will be forwarded to the Participant.  The Participant must respond to the audit report within 30 days of the
        report and, concurrently, the report must be sent to the CBP QAO and the State representative.

        4.5.1    If the Participant fails to take appropriate corrective action to resolve the deficiencies discussed in the
                on-site reports, any further sampling or analytical activities will not be conducted.
                                                  11-29

-------
                                                                                     Chapter II
                                                                             Quality Assurance
                                                                                  August 1996
                                        SECTION H

                                    REFERENCES
U.S. Environmental Protection Agency. 1983. Chesapeake Bay: A Framework for Action, Appendix F - A Monitoring
       and Research Strategy to Meet Management Objectives. Chesapeake Bay Liaison Office, Annapolis, MD.

U.S. Environmental Protection Agency. 1986. Quality Assurance Program Plan for the Chesapeake Bay Program.
       Region 3, Chesapeake Bay Liaison Office, Annapolis, MD.

U.S. Environmental Protection Agency. 1991. Chesapeake Bay Coordinated Split Sample Program Implementation
       Guidelines, Revision 3, CBP/TRS 58/91. Analytical Methods and Quality Assurance Workgroup of the
       Chesapeake Bay Program Monitoring Subcommittee, Chesapeake Bay Program Office, Annapolis, MD.
                                             11-30

-------
                                                               Chapter III
                                                         Data Management
                                                             August 1996
                        CHAPTER III

            DATA MANAGEMENT AND
       DELIVERABLE REQUIREMENTS
Section A.    Automation of Data Collection

     1. Introduction
     2. Development Phases
     3. Training

Section B.    Hardware Requirements for Automated Entry and Storage

     1. Minimum requirements

Section C.    Contract Reports and Deliverable Distribution

     1. Deliverables
     2. Archive of Results
     3. Data Dictionary
                                  III-l

-------
                                                                                Chapter III
                                                                         Data Management
                                                                              August 1996
                                 SECTION A

          AUTOMATION OF DATA COLLECTION
Introduction

The contractor will be provided with an automated data entry program to input for each water quality data
submission and output deliverables in an acceptable format to the Chesapeake Bay Program Office (CBPO).
 This submission will consist of cruise data, field parameter data, and laboratory analysis data including the
quality control data points. This program is currently under development by the EPA and will be available prior
to contract award. The purpose of this automated data tool is to:

        o Increase the quality of the CBP monitoring data;
        o Decrease data processing;
        o Standardize data management procedures.

Development Phases

The automated system is being developed in three phases.  Phase 1 will be available upon contract award, phase
2 and 3 may be implemented at any time during the contract period.  The features of each phase are noted
below.

Phase 1 will provide:

        o Manual data entry of cruise, field and lab results;

        o Manual data entry of quality control results as required by the  Chesapeake Bay Program Data
        Management Plan (DMP);

        o Create graphical, visual, and hardcopy  output of data for both field and laboratory data.

        o Perform automatic checking of field and lab results for valid entry, such that only numbers that are
        possible for that parameter are accepted;

        o Automatic statistical range check on vertical profile parameters compared to historical CBP
        monitoring data for that station/depth;

        o An error report to flag missing or out of range data points;

        o File output for submission to the CBP monitoring program in an acceptable format.
                                        III-2

-------
                                                                                   Chapter III
                                                                            Data Management
                                                                                 August 1996
Phase 2 will provide:
        o Evaluates quality control (QC) data to ensure that values are within the QC limits established by the
        Scope of Work (SOW);

        o Entry of field parameter data electronically;

        o Entry of laboratory data electronically via the EPA's ESF format from EPA Order 2180.2, the EPA
        DATA  STANDARDS FOR THE   ELECTRONIC  TRANSMISSION  OF  LABORATORY
        MEASUREMENT RESULTS. The contractor will be responsible to create the data file from the
        instrument in ESF format.

Phase 3 will provide:

        o Integration of quality control charts to the laboratory quality control data;
 The contractor will enter cruise, field and laboratory data information into this automated program (see
hardware requirements below). For cruise and field data, this program will accept manual keyboard input. For
laboratory analysis data, this program will accept manual keyboard input. This program will provide a first
level of range checking and quality control as outlined within the constraints of this Monitoring Program, this
SOW and the Data Management Plan (DMP). Double key entry will be required.

It is the responsibility of the contractor to keep hardcopy records and source documents for the cruise, field and
laboratory analysis data.
The EPA will provide training at the beginning of the contract period to four contractor employees on the use
of this EPA supplied software program. Updates or enhancements for the software program will be supplied
at no cost and training will be provided. A Users' Manual will also be provided on the operation of the software
program. Hence forth, throughout the contract period, it will be the responsibility of the contractor to train their
staff members.
                                         Ill-:

-------
                                                                       Chapter III
                                                                 Data Management
                                                                      August 1996
                               SECTION B
HARDWARE REQUIREMENTS FOR AUTOMATED ENTRY

                             AND STORAGE

    Minimum requirements

    The minimum hardware requirements for the EPA's automated entry and storage program are an IBM
    compatible personal computer running DOS 3.3 or greater with 640K RAM, a 60 megabyte hard disk, an Intel
    80286 processor, a 1.4 megabyte 31/2 inch diskette drive, an EPSON FX100 or compatible printer, and a 2400
    baud modem with PROCOMM.
                                     III-4

-------
                                                                                       Chapter III
                                                                                Data Management
                                                                                     August 1996
                                        SECTION C
  CONTRACT REPORTS AND DELIVERABLE DISTRIBUTION

1.       Deliverables

1.1      Each cruise

        For each cruise submission, the following deliverables will be required.

        On 31/2 inch IBM compatible floppy diskette:

        1.1.1. An ASCII format copy of the Data Submission Document File (DSDOC) as detailed in the DMP;

        1.1.2. The output file(s) from the automated data entry system.


        In hardcopy format:

        1.1.3. The error report produced by the automated data entry system;

        1.1.4. The data verification plots produced by the automated data entry system;

        1.1.5. Other field and lab sheets as outlined in Chapter II, Section B.I. Reporting.

1.2      Other reports

        For each reporting quarter of the contract period, a Quarterly Report must       be submitted. The format and
contents for this are outlined in the EPA    Scope of Work for the Chesapeake Bay Program.


2.       Archive of Results

        The contractor will keep two electronic media backups of each cruise submission.  This will include the cruise,
        field and laboratory data for the period of the contract. This data will be retained for five years from the date
        of collection and the contractor will be responsible to resolve any issues related to the data.

        In addition, one hardcopy of the error reports must be retained.


3.       Data Dictionary

        Prior to contract award, an integrated data dictionary representing all data elements required for this monitoring
        program as outlined in the automated data entry system's User's Guide will be available.
                                               m-5

-------
                                                                  Chapter IV
                                                       Water Quality Monitoring
                                                                 August 1996
                         CHAPTER IV
       WATER QUALITY MONITORING
Section A.      Introduction

      1.     Objectives and Scope
      2.     Rationale

Section B.      WQ Parameter List and Detection Limits

Section C.      Field Measurements and Sampling

      1.     Introduction
      2.     Field Measurements
      3.     Sampling
                                   IV-1

-------
                                                                                            Chapter IV
                                                                            Water Quality Monitoring
                                                                                          August 1996
                                          SECTION A

                                      INTRODUCTION
1.       Objectives and Scope

1.1     Objectives: Data generated using the procedures in this chapter will be used to meet the water quality
        monitoring objectives of the Chesapeake Bay Water Quality Program. These objectives are:

        ••      To characterize the present state of the Bay and its tributaries (baseline), including spatial and
                seasonal variation, using key water quality indicators.

        • •      To determine long-term trends or changes in key water quality indicators in relation to pollution
                control programs.

        • •      To integrate the information collected in all components of the Monitoring Program to gain a more
                comprehensive understanding of water quality processes and the relationship between water
                quality and living resources.

1.2     Scope: The scope of work for the Water Quality Monitoring Program includes the measurement of the
        chemical and physical parameters for the water column.  Parameters such as nutrients, chlorophyll,
        dissolved oxygen, and water transparency, were selected to provide information to identify nutrient trends,
        calibrate the water quality models for the Chesapeake Bay, and to correlate living resource data to the water
        quality data. Other parameters such as salinity and temperature are necessary to provide a more rigorous
        interpretation of these key water quality indicators. The information from these parameters with their
        associated detection limits will demonstrate if the water quality goals established for the living resource
        habitat have been met and will assist managers in instituting programs to regulate controls for point and
        non-point sources.  A complete listing of the water quality parameters and the detection limit requirements
        is provided in Table IV. 1.

2.       Rationale

In the 1983 document entitled "Chesapeake Bay:  A Framework for Action" the U.S. EPA recommended that a long-
term water quality monitoring program was necessary. The purpose of this program is to provide data so that the
current state of the Bay can be described and long-term changes can be detected.
                                                 IV-2

-------
                                                 Chapter IV
                                        Water Quality Monitoring
                                                August 1996
                   SECTION B
WQ PARAMETER LIST AND DETECTION LIMITS
                      TABLE IV. 1
Field Parameter
Secchi depth
pH
Dissolved oxygen
Specific Conductance
Salinity
Light attenuation
Depth
Temperature
Laboratory Parameter
Total dissolved phosphorus
Dissolved orthophosphate
Paniculate phosphorus
Nitrite
Nitrate + Nitrite
Ammonia
Total dissolved nitrogen
Paniculate carbon
Paniculate nitrogen
Detection Limit
0.1 meters
0.01 pH
0.02 mg DO/L
10% of scale
0.1 ppt
0.05% @ 100% light
0.02 meters
0.1 C
Detection Limit
0.001 mg TDP-P/L
0.0006 mgPO4-P/L
0.0012mgPHOSP-P/L
0.0002 mg NO,-N/L
0.0002 mg NO,+NO,-N/L
0.004 mg NH4-N/L
0.026 mg TDN-N/L
0.097 mg PC/L
0.019 mgPN/L
Upper
Standard


















                        IV-3

-------
                                   Chapter IV
                      Water Quality Monitoring
                                  August 1996
Dissolved organic carbon
Chlorophyll A
Phaeophytin
Total Suspended Solids
Silicates
0.5 mg DOC/L
1.0»gChla/L
1.0 Pheo • g/L
2 mg TSS/L
0.013 mgSi/L





IV-4

-------
                                                                                         Chapter IV
                                                                          Water Quality Monitoring
                                                                                        August 1996
                                         SECTION C

                FIELD MEASUREMENTS AND SAMPLING
1.      Introduction

1.1    Sampling Stations: Forty-nine stations in the Chesapeake Bay and fifty stations in the Bay tributaries shall
be sampled for water quality in support of the Chesapeake Bay Monitoring Program. Station latitudes and
longitudes are provided in Table IV. 1. ^

1.2    Sampling Schedule

       1.2.1     Sampling occurs 14 times a year. The Maryland Department of Natural Resources (MDNR) and
               Virginia Department of Environmental Quality (VDEQ) collaborate to develop an annual sampling
               schedule that will ensure that samples are collected by both groups within reasonably the same
               time period.

       1.2.2     The station sampling schedule is submitted to the EPA Grant Project Officer.

       1.2.3     Weather and sea conditions permitting, all field monitoring and sample collections for each
               mainstem cruise shall be completed during three days; and all field monitoring and sample
               collections for each tributary cruise shall be completed as closely as possible to the mainstem
               dates.  Due to the large distance which must be covered in a single day of sampling, it is not
               practical to sample  stations at a selected tidal stage. Instead, cruises shall begin on the designated
               date in the early morning (staging usually at 5:45 AM) and shall be completed by evening (usually
               6 or 7 PM).  Sampling should occur during daylight hours. In addition, all "light measurements",
               i.e., secchi depth and light attenuation, must only be measured during daylight hours. However, if
               there are unforeseen circumstances that these requirements can not be met, the deviations should
               be documented  at the end of the cruise in the CBP  Cruise Report.

1.3    Number of Samples: The  number of grab samples taken and  the depth at which they are taken varies. At
       designated  stations, four samples will always be collected, surface, bottom and either above and below
       pycnocline  if one is present or 1/3 and 2/3 the  total depth or above and below the pycnocline, depending on
       the absence or presence of a pycnocline. At other stations two samples (surface and bottom) are collected.
       The presence of a pycnocline  and the sampling depths are determined according to the procedures found in
       Chapter IV Section C 2.4 and 3.3.
                                                IV-5

-------
                                              Chapter IV
                                 Water Quality Monitoring
                                             August 1996
          TABLE IV.2
SAMPLING STATION LOCATIONS
Station Name
CB5.4
CB5.4W
CB5.5
EE3.4
EE3.5
LE3.6
LE3.7
CB6.1
CB6.2
CB6.3
CB7.1N
CB7.1
CB7.1S
CB7.2
CB7.2E
WE4.1
WE4.2
WE4.3
WE4.4
LE5.5
CB8.1
CR 8 IF
Latitude
37 48 00
37 48 48
374130
37 54 30
374733
373548
373150
3735 18
3729 12
372441
37 46 30
374100
37 34 52
372441
372441
371842
37 1430
37 1036
37 06 36
365948
365915
36 56 49
Longitude
76 10 30
76 17 42
76 1124
75 47 30
75 50 37
76 17 06
76 18 25
76 09 45
76 09 24
76 09 36
75 58 30
75 59 24
76 03 30
76 04 48
760130
76 20 48
76 23 12
76 22 24
76 17 36
76 18 12
76 10 05
7601 30
CBP Segment
CBS
CB5
CB5
EE3
CB7
CB6
LE3
CB6
CB6
CB6
CB7
CB7
CB7
CB7
CB7
WE4
WE4
WE4
WE4
CBS
CBS
CR8
River
CBAY
CBAY
CBAY
TANG S
CBAY
CBAY
RAPPA
CBAY
CBAY
CBAY
CBAY
CBAY
CBAY
CBAY
CBAY
MOBJAC
MOBJAC
MOBJAC
MOBJAC
CBAY
CBAY
CRAY
            IV-6

-------
                                               Chapter IV
                                  Water Quality Monitoring
                                             August 1996
     TABLE IV.2 (Continued)
SAMPLING STATION LOCATIONS
Station Name
CB7.4N
CB7.3
CB7.3E
CB6.4
ELI2
WBE1
SBE2
SBE5
EBE1
Latitude
37 03 29
37 07 00
37 13 43
371411
36 52 56
365035
36 48 45
3646 11
36 50 26
Longitude
75 58 23
76 07 32
76 03 15
76 12 30
762021
762135
76 18 22
76 17 47
76 17 22
CBP Segment
CB7
CB7
CB7
CB6
LE5
LE5
LE5
LE5
LE5
River
CBAY
CBAY
CBAY
CBAY
ELIZABETH
ELIZABETH
ELIZABETH
ELIZABETH
ELIZABETH
             IV-7

-------
        TABLE IV.3
CRUISE SCHEDULE FOR 1996
                                            Chapter IV
                               Water Quality Monitoring
                                           August 1996
Month
January
February
March
April
April
May
May
June
July
July
August
August
September
October
November
Dprpmbpr
Cruise Number
231
232
233
235
236
237
238
239
241
242
243
244
245
247
249
950
Maryland Mainstem
Special
Special
11-13
8-10
22-24
13-15
28-30
10-12
8-10
22-24
5-7
26-28
9-11
7-9
18-20
9-11
Virginia Mainstem
16-19
12-15
11-14
8-11
No Cruise
13-16
No Cruise
10-13
8-11
22-25
5-8
26-29
9-12
7-10
18-21
9-19
          IV-8

-------
                                                                                              Chapter IV
                                                                             Water Quality Monitoring
                                                                                            August 1996
2.      Field Measurements
2.1    At each station, the latitude and longitude (accurate within + 15 seconds) in degrees, minutes and seconds
       should be recorded at the beginning of sampling. To obtain accurate location data, Global Positioning
       Systems (GPS) is recommended for use. The CBP segment location and total depth should also be recorded.

2.2    The weather and sea conditions at the time of sampling should also be recorded. General weather conditions
       include cloud cover, air temperature, precipitation type, wind speed, and wind direction.  Sea conditions that
       should be recorded include wave height and tidal current stage.

2.3    Secchi depth

       2.3.1     Equipment: A 20 cm Secchi disk, a circular plate-like disk painted in alternating black and white
                quadrants is held by a line that is marked in tenths of meters.

       2.3.2     Frequency:  The Secchi depth is determined at each station.

       2.3.3     Procedure: The Secchi disk is used to give a measurement of transparency of the water column,
                also called the Secchi depth.

                2.3.3.1   Slowly lower the Secchi disk until it is no longer visible and note the depth using the
                         markings on the line.

                2.3.3.2   Slowly raise the Secchi disk until it just becomes visible and note the depth using the
                         markings on the line.

                2.3.3.3   Perform steps 2.3.3.1 and 2.3.3.2 three times, noting both readings. Record average.

       2.3.4     Quality control

                2.3.4.1   If the range of measurements for the three sets of readings in section 2.3.3 is greater than
                         0.5 m, the entire process should be performed again. Raise and lower several times
                         around "disappearing" point.

                2.3.4.2   No sunglasses or any other devices should be used to shade the eyes while this procedure
                         is being performed.

                2.3.4.3   The Secchi depth should be determined from the shady side of the boat during daylight
                         hours.
                                                  IV-9

-------
                                                                                             Chapter IV
                                                                            Water Quality Monitoring
                                                                                           August 1996

2.4    Physiochemical Profile

       2.4.1     Equipment

                2.4.1.1  A multi-parameter water quality instrument, such as a Sea-bird Sealogger CTD, or any
                        combination of equipment that can provide the same measurements, shall be used.

                2.4.1.2  The instrument shall be equipped with the following sensors:
                                ••      pressure sensor - used to determine sampling depth,
                                • •      a bottom sensor - sounds an alarm on deck when the unit is approaching
                                        the bottom,
                                • •      Ph meter,
                                • •      dissolved oxygen probe, and
                                ••      light attenuation sensor - LI-COR LI-192SA underwater sensor, or
                                        equivalent
                                ••      temperature sensor
                                ••      conductivity cell

                2.4.1.3  The instrument should be outfitted with a system so that field measurements can be
                        logged from the instrument by computer, with a manual recording backup capability in
                        case of computer failure for as many parameters as possible.

       2.4.2     Frequency: The physiochemical profile is determined at every sampling station.  The surface
                reading is taken at 0.5m (MD) and 0.1m (VA) below the surface.  Readings are then recorded for
                1m, 2m, and 3m below the surface. Finally, readings every 2m to 1m above the bottom. For
                stations less than 10m readings should be made every meter.

       2.4.3     Procedure:  The following parameters should be measured at the frequency described in 2.4.2:
                water temperature, Ph, dissolved oxygen, salinity, light attenuation, depth of measurements,
                surface radiation, and total depth. The  sampling boat should be oriented so that the light sensor is
                not in the shadow of the boat during data collection. All apparatus should be operated according
                to manufacturer's instructions.

       2.4.4     Quality control

                2.4.4.1  Calibration:  All probes must be calibrated by manufacturers recommended methods..

                        2.4.4.1.1        Conductivity sensor:  The conductivity sensor must be calibrated
                                        against a reference solution, according to manufacturer's specifications.
                                        As a minimum conductivity should be verified before and after each
                                        cruise.

                        2.4.4.1.2        Ph meter: As a minimum the pH sensor must be calibrated at the
                                        beginning and end of every cruise against two buffer solutions, pH 7
                                        and 10. The pH probe must be rinsed with deionized water and may
                                        need to be soaked in pH 7 buffer when not in use.  If the probe drifts ±
                                        0.2 pH units, the sensor must be recalibrated using the pH 7 and  10
                                        buffers.

                        2.4.4.1.3        Dissolved oxygen meter: The dissolved oxygen meter should be
                                        verified using air-saturated water at the beginning of each day.

                                                 IV-10

-------
                                                                                           Chapter IV
                                                                           Water Quality Monitoring
                                                                                          August 1996

                                        Periodic verification checks should be performed using Winkler
                                        titrations. If titrations differ by + 0.5 mg/1 from probes readings the
                                        validity of the readings should be verified.

                        2 A A.I A         Thermometer: Calibrate the thermometer once a year against a NIST
                                        certified thermometer over a range of temperatures.

                        2.4.4. 1.5         Pressure sensor:  Calibrate the depth sensor once a year according to
                                        the manufacturer's instructions.

                2.4.4.2  The Contractor must maintain logbooks with calibration, replicate, and maintenance
                        information for each instrument and/or probe.

       2.4.5     Pycnocline determination: The pycnocline is a region in which the water density changes
                appreciably with increasing depth and thus forms a layer of much greater stability than is provided
                by overlying surface waters. The pycnocline calculated threshold value (CTV) is calculated using
                Equation IV. 1. If the CTV is less than 500 microohms/cm, then there is no discernible pycnocline.
                If the CTV is above 500 microohms/cm, a pycnocline exists with boundaries at the first and last
                depths where the change in conductivity is greater than the CTV.
       Where            Cb      = bottom conductivity  (microohms/cm),
                        Cs      = surface conductivity  (microohms/cm),
                        Db      = depth of bottom conductivity measurement (m),
                        Ds      = depth of surface conductivity measurement (m),
                        CTV    = calculated threshold value (microohms/cm)
3.      Sampling

3.1     Equipment
       3.1.1     Collection bottles: Two-Four bottles per sampling station.

       3.1.2     Hydrocast sampling system: General Oceanics Model 1016 Rosette sampling system, or
                equivalent.

       3.1.3     Laboratory sample bottles

                        NOTE: Always ensure sample bottles are in a clean state or have been thoroughly
                        cleaned before reuse.  Where ever possible, do not use sample bottles from high
                        concentration samples for low level events.
                                                IV-11

-------
                                                                                            Chapter IV
                                                                            Water Quality Monitoring
                                                                                          August 1996
3.1.4   Filtration apparatus.
       3.1.5     Filters:
                Note: Specific filter types and diameters are cited, however, alternate diameters can be used.  See
                specific comments throughout the analytical methodology about concerns related to alternate sizes.

                3.1.5.1  Whatman GF/F 25 mm diameter, 0.70 • m pores.

                3.1.5.2  Whatman GF/F 47 mm diameter, 0.70 • m pores.  Pre-wash, dry at 103-105°C, and weigh
                        until a constant weight ±.05 mg is reached. Store in a desiccator while cooling and until
                        weighed.
                3.1.5.3  Whatman GF/F 47 mm diameter, 0.70 um pores. Untreated for chlorophyll analysis.

       3.1.6     Cooler and freezer.

3.2    Reagents

       3.2.1     Magnesium carbonate suspension:  Add 1 g of finely powdered MgCO3 to 100 mL water.

       3.2.2     Sulfuric acid, H2SO4 (6N) // Hydrochloric acid, HC1 (6N).

       3.2.3     Reagent water, all water referred to in this document, unless otherwise specified, is ASTM Type II
                water, or equivalent.

3.3    Sample Collection

       3.3.1     The cruise vessel should ensure location by LORAN and anchor while taking samples. At those
                stations where anchoring is not practical, the LORAN shall be used to hold station.  The LORAN
                coordinates must be recorded at the beginning of the sampling time. It must be recorded whether
                the boat anchored or the station was held using the LORAN.

       3.3.2     At stations where pycnocline sampling is designated, if a pycnocline is detected, samples are
                collected 0.5m (MD) and 1.0 (VA) mbelow the surface, 1.0 m above the upper boundary of the
                pycnocline, 1.0 mbelow the lower boundary of the pycnocline, and 1.0 m above the bottom to
                nearest 0.5 m.  See Chapter IV Section C 2.4.5 for pycnocline calculations and definitions.

       3.3.3     If there is no discernable pycnocline at designated stations collections will be made at 0.5 m (MD)
                and 1.0 (VA) mbelow the surface, at the closest profile depth above one third of the distance
                between the surface depth, 1.0m, and the bottom sample depth, at closest profile depth below two
                thirds the distance between 1.0 m and the bottom sample depth, and 1.0 m above the bottom to the
                nearest 0.5 m.

       3.3.4     At all other stations, samples are only collected at the 1mbelow the surface and 1m above the
                bottom.

       3.3.5     Lower the collection system to each sampling depth and fill one bottle per depth. Process the
                sample according to 3.4.

3.4    Sample Processing

                                                 IV-12

-------
                                                                                    Chapter IV
                                                                    Water Quality Monitoring
                                                                                   August 1996

3.4.1     Sample processing and division for all samples should follow Figure IV.2.

3.4.2     Chlorophyll and phaeophytin:  Process sufficient sample (i.e. 100-1500 mL) to produce a green
         color on the filter pad.  For smaller diameter filters (i.e., 13 mm), do not exceed the capacity of the
         filters with large volumes of sample (i.e., greater than 50ml).
                                          IV-13

-------
                                                                       Chapter IV
                                                         Water Quality Monitoring
                                                                     August 1996
                                FIGURE IV.2
                        SAMPLING AND PROCESSING

Arrive



Take LORAN Readings
                        Weather and Sea Conditions
                           Physiochemical Profile
                            Compute Pycnocline
                          Collect Samples Based on
                           Pycnocline Calculations
                                Analyze for N02,NH4,
                                  N02+N03, TDN
Discard Filtrate Grind Tissue
  and Extract Chlorophyl
Analyze for Chlorophyll
     Pigments
                                   IV-14

-------
                                                                                                   Chapter IV
                                                                                  Water Quality Monitoring
                                                                                                 August 1996

                3.4.2.1  Immediately concentrate the algae by filtering a known volume of sample water (measured with a
                        graduated cylinder) onto a glass fiber filter (Whatman GF/F or equivalent). To avoid cell damage and
                        loss of contents during filtration, do not exceed a vacuum of l/i atm (50 kPa or 15 psi), or a filtration
                        duration greater than 5 minutes. Add 1ml of saturated MgCO3 solution 10mg/l during last few
                        seconds of filtering

                3.4.2.2  Samples that cannot be concentrated immediately  after collection may be held at 0 to 4°C in the dark
                        for 4 hours before the plankton are concentrated, however any delay is strongly discouraged due to the
                        possible lysis of phytoplankton cells.  The residue on the filter may be stored in the dark at -20 ± 2°C
                        for 28 days before extracting the pigments.

       3.4.3     Paniculate carbon and paniculate nitrogen:  25-500 mL of sample is filtered under vacuum through each of two
                13 mm GF/F filters.  The filters are stored in Petri dishes or foil pouches at -20 ± 2°C. Do not rinse the filters.
                Do not exceed 15 psi while filtering.

       3.4.4     Ammonia, nitrite, nitrite+nitrate, orthophosphate, total dissolved nitrogen, total dissolved nitrogen, dissolved
                organic carbon, and silicates: The filtrate is stored at -20°±2°C for laboratory analysis, except for silicates,
                which is stored at 4°±2°C. The DOC samples  should have acid preservation (HC1 or H2SO4) or be frozen.

       3.4.5     Total suspended solids and paniculate phosphorus:  50-1000 mL of sample is filtered under vacuum through
                two prepared 47 mm GF/F filters. The filters are stored in Petri dishes or foil pouches at -20 ± 2°C. If separate
                filters are  obtained for each analyses, then the total suspended solids filter can be stored at 4°±2°C.  These
                filters should be rinsed three times with at least 10 ml DI water. If filtrate is saved must save before rinse.

       3.4.6     Dissolved orthophosphate and total dissolved phosphorus: The filtrate used to prepare filters for particulate
                phosphorus and total suspended solids is stored at -20 ± 2°C for laboratory analysis.


3.5    Quality control

       3.5.1     Field blanks: A field blank is an equivalent aliquot of reagent water that is processed as a sample. The field
                blank should be processed at the beginning of every sampling day. If the concentration of any analytes exceeds
                the MDL, equipment contamination should be  suspected.

       3.5.2     Field duplicates: A field duplicate is a sample taken at  the same sample location and depth as a CBP sample.
                The duplicate and sample should be taken in quick succession of each other.  A field duplicate should be
                collected once for every 10 CBP  samples. The data from field duplicates indicates sampling precision.
                                                       IV-15

-------
                                                                         Chapter IV
                                                             Water Quality Monitoring
                                                                          August 1996
                             CHAPTER  IV
        WATER QUALITY MONITORING
Section D.       Laboratory Analysis

       1.  General Laboratory QA/QC
       2.  Total Dissolved Phosphorus
       3.  Dissolved Orthophosphate
       4.  Paniculate Phosphorus
       5.  Nitrite
       6.  Nitrate + Nitrite
       7.  Ammonia
       8.  Total Dissolved Nitrogen/Particulate Nitrogen
       9.  Paniculate Carbon
       10. Dissolved Organic Carbon
       11. Biological Oxygen Demand, 5-day
       12. Chlorophyll and Phaeophytin
       13. Total Suspended Solids
       14. Fixed Suspended Solids
       15. Silicates
       16. Alkalinity
                                        IV-15

-------
                                                                         Chapter IV
                                                             Water Quality Monitoring
                                                                          August 1996


                                   SECTION D

                         LABORATORY ANALYSIS

1.    General Laboratory QA/QC

1.1   Sample storage and holding times

     1.1.1     The following holding times should not be exceeded and the temperatures given should be
              maintained.

                                      TABLE IV.4
          WQ LABORATORY PARAMETER HOLDING TIMES AND TEMPERATURES
Parameter
Total dissolved phosphorus
Dissolved orthophosphate
Paniculate phosphorus
Nitrite
Nitrate + nitrite
Ammonia
Total dissolved nitrogen
Paniculate nitrogen
Paniculate carbon
Dissolved organic carbon
Chlorophyll and phaeophytin
Total suspended solids
Silicates
Holding Time (days)
28
28
28
28
28
28
28
28
28
28
30
7
28
Temperature (°C)
-20
-20
-20
-20
-20
-20
-20
-20
-20
-20 or acidify
-20
4
4
     1.1.2     Time allowed for field processing

     1.1.3     If samples are analyzed within 24 hrs, then samples may be refrigerated (4° C) rather than frozen.
                                        IV-16

-------
                                                                                         Chapter IV
                                                                           Water Quality Monitoring
                                                                                          August 1996


       1.1.4      The samples should be stored in an atmosphere free of all potential contaminants.

       1.1.5      Samples and standards should be stored separately.

1.2     Method Blank

       1.2.1      A method blank is a volume of ASTM Type II reagent grade water that is carried through the
                 entire analytical procedure.   The purpose of a method blank is to determine the levels of
                 contamination associated with the processing and analysis of samples.

       1.2.2      A method blank should be analyzed once for every 10-20 CBP samples, including duplicates.

       1.2.3      If the concentration of analyte exceeds the MDL, laboratory or reagent contamination should be
                 suspected.  If the analyte concentration is 5 times the MDL or greater, then corrective action is
                 required and reanalysis if possible.

1.3     Matrix Spike (not required for chlorophyll, PN, PHOSP, TSS,  PC)

       1.3.1      In order to evaluate the effects of the sample matrix on the analytical methods, a known quantity
                 of analyte is spiked in an aliquot of sample.  The analyte concentration should be high enough to
                 be seen over the original concentration of the sample and should not be less than four times the
                 calculated MDL.

       1.3.2      A matrix spike should be analyzed once for every  10-20 CBP samples.

       1.3.3      Matrix spikes should not be performed on laboratory or field blanks.

       1.3.4      The percent recovery of analyte from the  matrix spike sample is calculated using the following
                 equation:
                                             _ PD
          Matrix Spike Recovery  = -^ - —  x  100                                                (Eq. IV. 2)
                 where,

                               SSR  = Spike sample result
                               SR  = Sample result
                               SA  = Spike added

       1.3.5      If the recovery of the analyte falls outside the range designated in Table II. 1, repeat the spike
                 after checking for obvious sources of error.  If the recovery of the replicated spike of the same
                 sample again falls outside the designated range, the recovery problem encountered with the
                 spiked sample is judged to be matrix related, not system related and no further corrective action
                 is required.
                                                 IV-17

-------
                                                                                       Chapter IV
                                                                         Water Quality Monitoring
                                                                                       August 1996
1.4    Laboratory Replicates
      1.4.1       Laboratory replicate analyses provide a measure of laboratory precision. Duplicates are prepared
                 by taking two aliquots for analysis from a well homogenized sample. More replicates may be
                 analyzed and reported.

      1.4.2       A laboratory duplicate should be analyzed once for every 10-20 CBP samples.

      1.4.3       The precision may be measured by calculating the coefficient of variation (CV) using the
                 following equation:
      CV  = -— x  100, where SD  = .
             MEAN                        \
                                                   (x
(N-  1)
                 where,
                              CV =  Coefficient of variation
                              SD  =  Standard deviation
                              Mean = Mean of the replicate readings
                              N  = Number of samples

      1.4.4       The precision may be measured by calculating Relative Percent Differnce (RPD). The following
                 equation is used to calculate RPD:


                               RPD = [ | Al -A21 +((A1 +^2)-2)] * 100


1.5    Check Standard- An a accurately prepared chemical standard that is analyzed after every 10-20 CBP
      samples. The results are compared to the known analyte concentration. If the determined concentration for
      known analysis is not within 90-110% of the known analyte concentration, a second check standard is
      prepared and analyzed to confirm or deny the initial "out of control" analysis. If the reanalyzed check
      standard is within acceptance limits, sample analysis proceeds; however, if the reanalyzed check standard
      fails the acceptable limits, the instrument must be recalibrated. All the samples between that check standard
      and the previous standard must be reanalyzed.

1.6    Reference Materials

      1.6.1       Standard reference materials shall be analyzed at the frequency defined within each method.

1.7     See synthetic sea water: Strickland and Parsons

      1.7.1       Using analytical reagent grade reagents, dissolve 3 Ig of Sodium Chloride NaCl (CAS No. 7647-
                 14-5),  lOg of magnesium sulfate, Mg SO4 7H20 (CAS No.  10034-99-8) and 0.05g sodium
                 bicarbonate (NaHCO3H2O) (CAS No. 144-55-8) in  1 liter of reagent water.
                                               IV-18
                                                       (Eq. IV.3)

-------
                                                                                      Chapter IV
                                                                        Water Quality Monitoring
                                                                                       August 1996
1.8 Glassware Cleaning
      1.8.1       Standard and Reagent Glassware should be rinsed with 10% HC1 once and then rinsed 3 times
                 with reagent grade water.

      1.8.2       Sample Containers should be rinsed with tap water, 10% HC1 and then rinsed 4 times with
                 reagent water.  Then, before use they should be rinsed 3 times with sample.

      1.8.3       AutoAnalyzer Cups  should be rinsed two-three times with the sample, and then filled.

1.9    Reagent grade water: ASTM Type II reagent grade water, or equivalent, should be used in the preparation of
      reagents and standards. Reverse  osmosis systems or distilling units which produce 18 megohm water are two
      examples of acceptable water sources.
                                               IV-19

-------
                                                                                         Chapter IV
                                                                           Water Quality Monitoring
                                                                                          August 1996


2.      Total Dissolved Phosphorus

2.1    Scope and Application

       2.1.1      This method provides the procedure for the determination of low level total dissolved phosphorus
                 concentrations normally found in estuarine and /or coastal waters by the automated persulfate
                 oxidation technique in the range of 0.001 to 2.0 mg/L of P.

2.2    Summary of Method

       2.2.1      This method involves the digestion of the sample with an oxidizing agent (alkaline persulfate) in
                 an autoclave, which converts all the phosphorus compounds to orthophosphate. This is followed
                 by analysis for orthophosphate by an automated colorimetric method.

       2.2.2      The color in the samples is measured in the following manner. Ammonium molybdate and
                 antimony potassium tartrate react in an acid medium with dilute solutions of phosphorus to form
                 an antimony-phospho-molybdate complex.  This complex is reduced to an intensely blue-colored
                 complex by ascorbic  acid.  The color is proportional to the phosphorus concentration.

2.3    Interferences

       2.3.1      Silicon at a level of 100 • g/L causes an interference equivalent to approximately 0.04 • g/L of
                 P/L. This can be avoided by maintaining an acid concentration of 2.45N H2SO4 in the reagents
                 and analysis at 37 ± 2°C.

2.4    Apparatus and Materials

       2.4.1      Continuous flow automated analytical system equipped with an autosampler, manifold,
                 proportioning pump,  colorimeter, phototube, recorder or computer based data system, and
                 heating bath.

       2.4.2      Appropriate glassware.

                 NOTE:  Clean all culture tubes by adding 10ml persulfate digestion reagent and heating at 100°
                 C 1 hr, and rinse 3 times with reagent water.

       2.4.3      Autoanalyzer cups, see section 1.8.3 Do not reuse cups.

       2.4.4      An autoclave that can maintain a temperature of 100 -110°C.

       2.4.5      Culture tubes, 30 mL capacity.

       2.5        Reagents

       Stock Reagent Solutions

       2.5.1      Reagent  Grade Water: see section 1.9
                                                 IV-20

-------
                                                                                  Chapter IV
                                                                   Water Quality Monitoring
                                                                                  August 1996
2.5.2       Artificial Sea Water: See synthetic seawater 1.7
2.5.3       Borate Buffer Solution: To a two-liter volumetric flask, add approximately 800 mL of reagent
           water. Add 123.6 g of boric acid (H3BO3) and 16. Ig lowN sodium hydroxide (NaOH) and dilute
           to 2.0 L with reagent water. Store at room temperature.  Stable for two months.

2.5.4       Oxidizing Reagent: To a one-liter volumetric flask, add 400 mL of reagent water. Add 3.0 g of
           lowN NaOH and 20.0 g of low N (0.001%) potassium persulfate (K2S2O8), dissolve, and dilute
           to one liter with reagent water.  Store in a glass reagent bottle. This solution is only stable for
           two hours at room temperature. Make fresh daily.

2.5.5       Sulfuric Acid Solution, 5N: In a 500-mL volumetric flask, add 300 mL of reagent water. Add 70
           mL of concentrated sulfuric acid (H2SO4). Cool to room temperature and dilute to 500 mL with
           reagent water.

2.5.6       Potassium Antimony Tartrate Solution: In a 500-mL volumetric flask, add 300 mL of reagent
           water. Add 0.3 g of K(SbO)C4H4O6*y2H2O,  dissolve, and dilute to volume with reagent water.
           Store in a glass-stoppered bottle at room temperature.

2.5.7       Ammonium Molybdate Solution: In a 500-mL volumetric flask, add 400 mL of reagent water.
           Add 4 g of ammonium molybdate (NH4)6Mo7O24'4H2O, dissolve, and dilute to volume with
           reagent water. Store in a plastic bottle at 4 ± 2°C.

2.5.8       Ascorbic Acid: In a 100-mL volumetric flask, add 50 mL of reagent water. Add 1.8 g of
           ascorbic acid, dissolve, and dilute to 100 mL with reagent water.  This solution is stable for about
           one week at 4 ± 2°C.

2.5.9       Combined Reagent: In a 100-mL volumetric flask, add 50 mL of 5N H2SO4, 5 mL of potassium
           antimony tartrate solution, 15 mL of ammonium molybdate, and 30 mL of ascorbic acid.  All
           reagents should reach  room temperature before they are mixed. Add the reagents in the order
           given and mix the resultant solution after each addition.  The combined reagent is stable for 4
           hours.

Working Solutions

2.5.10      Stock Glycerophosphate Standard: In a 500-mL volumetric flask, add 400 mL of reagent grade
           water. Add 0.473 g of B-glycerophosphoric acid-disodium salt-5-hydrate, dissolve, and dilute to
           volume with reagent water. Add 0.5 mL of chloroform (under a hood)  as a preservative.  This
           solution is only stable  for ten months at 4 ± 2°C.

           2.5.10.1       Working Glycerophosphoric  Standard: In a 100-mL volumetric flask, add 50  mL
                        of substitute ocean water. Add 1.0 mL of stock glycerophosphate standard
                        solution, mix, and dilute to volume with substitute ocean water.  This solution
                        should be prepared on the day of analysis.  (1.0mL = 0.957 *gP)

2.5.11      Stock Phosphate Standard Solution: In a one-liter volumetric flask, add 500 mL of reagent water.
           Add 439.3 mg of anhydrous potassium dihydrogen phosphate  (KH2PO4) that has been dried
           overnight at 105 ± 2°C (stored in a desiccator), dissolve, and dilute to volume with reagent water.

                                         IV-21

-------
                                                                                          Chapter IV
                                                                           Water Quality Monitoring
                                                                                           August 1996


                  This solution is stable for six months at 4 ± 2°C. (1.0 mL = 100.0 • g P)

                  2.5.11.1      Working Standards

2.6    Sample Handling

       2.6.1       Samples are filtered through a Whatman GF/F glass fiber filter or equivaleant filter and can be
                  stored at -20 ± 2°C unacidified for a maximum of 28 days. They should not be preserved with
                  sulfuric acid. Do not freeze after digestion; a precipitate will form.

2.7    Procedure

       2.7.1       Sample preparation:

                  2.7.1.1       Pipet 10 mL of filtered sample into a 30 mL screw cap test tubes. Include  5-10%
                               duplicates and 5-10% spikes (spike with 0.30ml working standard).

                  2.7.1.2       Pipet 10.0 ml of working standards into 30 ml screw cap test tubes. Include two
                               oxidizing reagent blanks which contain only the oxidizing reagent.

                  2.7.1.3       Pipet 5.0 mL of the oxidizing reagent in each tube. Cap test tubes tightly  and very
                               quickly due to volatilization.

                                               NOTE: A precipitate (Mg(OH)2) will form with seawater
                                               samples which will not form with saline standards prepared with
                                               NaCl. If standards are made with Substitute Ocean Water the
                                               precipitate will form.

                  2.7.1.4       Autoclave tubes at a temperature between 100-110°C (follow Autoclave
                               instructions).

                  2.7.1.5       Remove tubes from the heating apparatus and cool to room temperature. Check
                               volumes for possible fluid loss and indicate any losses on bench sheet.  Samples
                               can be  refrigerated for several days at this point if necessary to delay analysis.

       2.7.2       Add 1.0 mL of borate  buffer solution to each tube and cap. Shake very well.  The pH of the
                  sample should be around 2. Samples can now be analyzed for orthophosphate.

       2.7.3       Allow both the colorimeter and recorder to warm up for 30 minutes. Obtain a stable baseline
                  with all reagents, feeding reagent water through the sample line.

       2.7.4       Prepare a series of standard solutions covering the concentration range  of the samples by diluting
                  either the stock or standard solutions and digesting them along with the samples.  Digest  matrix
                  spike and blanks along with the samples.

       2.7.5       Analytical sequence:  The samples and associated QC samples and standards should be
                  analayzed according to the following sequence.

                  2.7.5.1       Five calibration standards with concentration within  the linear range of the test.


                                                 IV-22

-------
                                                                                          Chapter IV
                                                                           Water Quality Monitoring
                                                                                          August 1996


                 2.7.5.2        Two method blanks.

                 2.7.5.3        Ten-twenty CBP samples.

                 2.7.5.4        One matrix spike sample.

                 2.7.5.5        One medium concentration calibration standard.

                 2.7.5.6        One method blank.

                 2.7.5.7        Steps 2.7.5.1 - 2.7.5.6 are repeated until all samples are analyzed or QC samples
                               indicate that the system is out of control and recalibration is necessary.

                 2.7.5.8        One high concentration calibration standard.

                 2.7.5.9        One medium concentration calibration standard.

                 2.7.5.10      One low concentration calibration standard.

       2.7.6      Switch  sample line from distilled water to  sampler and begin analysis.

       2.7.7      Prepare appropriate standard curve by plotting peak heights of processed standards against
                 known concentrations. Compute concentration of the samples by comparing sample peak heights
                 with standard curve.

                 NOTE:  Subtract the blank background response from the standards before preparing the
                 standard curve.

       2.7.8      Record the stabilized potential of each unknown sample and convert the potential to the TDP
                 concentration using the standard curve.

2.8    Quality Control

       2.8.1      Method detection limits (MDL):  Method detection limits should be established using the
                 guidelines in Chapter II, Section D.

       2.8.2      Calibration

                 2.8.2.1        Linear calibration range: Calibration standards should bracket the range of CBP
                               samples.

                 2.8.2.2        Correlation coefficient:  The correlation coefficient must be 0.995 or better for the
                               calibration curve to be used.

       2.8.3      Method blank:  see Chapter II, Section C.

       2.8.4      Matrix spike sample:  see Chapter II, Section C.

       2.8.5      Laboratory duplicate: see Chapter II, Section C.


                                                 IV-23

-------
                                                                                     Chapter IV
                                                                       Water Quality Monitoring
                                                                                     August 1996


      2.8.6      Reference materials: The laboratory must analyze a standard reference material once a year, as
                available.

2.9    References

      Standard Methods for the Examination of Water and Wastewater, 17th          Edition, p 1193.

      Annual Book of ASTM Standards, Part 31, "Water", Standard D 515-72, p 389 (1976).
                                              IV-24

-------
                                                                                         Chapter IV
                                                                           Water Quality Monitoring
                                                                                          August 1996


3.      Dissolved Orthophosphate

3.1     Scope and Application

       3.1.1      This method provides a procedure for the determination of low level Orthophosphate
                 concentrations normally found in estuarine and/or coastal waters. It is an automation of the
                 method of Murphy and Riley (1962).

       3.1.2      A method detection limit (MDL) of 0.0006 mg P/L has been statistically determined by one
                 laboratory. This MDL is defined as three times the standard deviation of at least seven replicates
                 of a low level estuarine (~15 parts per thousand salinity) sample. The method is linear to 0.050
                 mg P/L at a standard calibration setting of 9.0 on an AutoAnalyzer II  system. Where higher
                 concentrations are encountered, the method is also linear at lower standard calibration settings.

       3.1.3      This method should be used by analysts experienced in the use of automated colorimetric
                 analyses and matrix interferences and procedures for their correction. A minimum of six months
                 experience under supervision is recommended.

3.2     Summary of Method

       3.2.1      This is an automated colorimetric method for the analysis of low level Orthophosphate estuarine
                 samples. Ammonium molybdate  and antimony potassium tartrate react in an acid medium with
                 dilute solutions of phosphorus to form an antimony-phospho-molybdate complex. This complex
                 is reduced to an intensely blue-colored complex by ascorbic acid. The color produced is
                 proportional to the phosphate concentration present in the  sample.  A calibration curve is
                 established with standards of known concentrations and the unknown samples are measured
                 against the calibration curve.

3.3     Interferences

       3.3.1      It is reported that the interference caused by copper, arsenate and/or silicate is minimal to the
                 Orthophosphate determination because of their extremely low concentrations normally found in
                 estuarine or coastal waters.  High iron concentrations can cause precipitation of and subsequent
                 loss of phosphorus from the dissolved phase.  Hydrogen sulfide effects (samples collected from
                 deep anoxic basins) can be treated by simple dilution of the sample, since high sulfide
                 concentrations are most often associated with high phosphate values (Grasshoff, et al., 1983).

       3.3.2      Mercuric chloride, if used as a preservative, interferes (EPA, 1977).

       3.3.3      Sample turbidity should be removed by filtration prior to analysis.

       3.3.4      Refractive Index interferences should be corrected for estuarine/coastal samples.

3.4     Apparatus and Materials

       3.4.1      Continuous flow automated analytical system equipped with an autosampler, manifold,
                 proportioning pump, colorimeter, phototube, recorder or computer based data system, and
                 heating bath.
                                                 IV-25

-------
                                                                                        Chapter IV
                                                                          Water Quality Monitoring
                                                                                         August 1996


       3.4.2      Phosphate-free glassware: all glassware used in the determination must be low in residual
                 phosphate to avoid sample/reagent contamination.  Washing with 10% HC1 and thoroughly
                 rinsing with distilled/deionized water have been found to be effective.

3.5     Reagents

       3.5.1      Reagent Grade Water: see section 1.9.

       3.5.2      Substitute Ocean Water:  see section 1.7

       3.5.3      Stock Reagent Solutions

                 3.5.3.1       Ammonium Molybdate Solution (40 g/L):  Dissolve 20.0 g of ammonium
                              molybdate tetrahydrate [(NH4)6Mo7O24'4H2O, CAS RN 12027-67-7] in
                              approximately 400 mL of reagent water and dilute to 500 mL. Store in a plastic
                              bottle out  of direct sunlight. This reagent is stable for approximately three
                              months.

                 3.5.3.2       Antimony Potassium Tartrate Solution (3.0 g/L):  Dissolve 0.3 g of antimony
                              potassium tartrate [(K(SbO)C4H4O6«1/2H2O, CASRN 11071-15-1] in
                              approximately 90 mL of reagent water and dilute to 100 mL. This reagent is
                              stable for approximately three months.

                 3.5.3.3       Ascorbic Acid Solution (18.0 g/L):  Dissolve 18.0 g of ascorbic acid (Cfl6O6,
                              CAS RN 50-81-7) in approximately 800 mL of reagent water and dilute to one
                              liter. Dispense approximately 75 mL into clean poly bottles and freeze.  The
                              stability of the frozen ascorbic acid is approximately three months. Thaw
                              overnight  in the refrigerator before use. The stability of the thawed, refrigerated
                              reagent is  10 days.

                 3.5.3.4       Wetting Agent - use Skalar FFD6.

                 3.5.3.5       Sulfuric Acid Solution (5.0 N):  Add 140 mL concentrated sulfuric acid (H2SO4,
                              CAS RN 7664-93-9) to approximately 800 mL reagent water while cooling. After
                              the solution is cooled, dilute to 1000 mL with reagent water.

                 3.5.3.6       Stock Phosphorus Solution: Dissolve 0.439 g of pre-dried (105± 2°C for 1 hour)
                              potassium phosphate, monobasic (KH2PO4, CAS RN 7778-77-0) in reagent water
                              and dilute to 1000 mL (1.0 mL = 0.100 mg P). The stability of this stock standard
                              is approximately three months, if kept refrigerated.

       3.5.4      Working Reagents

                 3.5.4.1       Reagent A: Mix the following reagents in these proportions for 277 mL of
                              Reagent A: 125mL of sulfuric acid,  37.5 mL of PAT, 37.5 mL of Molybdate,
                              75ml of Ascorbic, and 2mL of FFD6. Prepare daily.

                 3.5.4.2       ReagentB: Add approximately 2.0  mL of the FFD6 solution to the  1000 mL of
                              DDL  Volumetric accuracy not required. Stability is approximately 10 days if


                                                IV-26

-------
                                                                                         Chapter IV
                                                                          Water Quality Monitoring
                                                                                         August 1996
                               kept refrigerated.
                 3.5.4.3        Refractive Reagent A:  Add 50 mL of 4.9 N H2SO4 to 20 mL of reagent water.
                               Add 1 mL of SLS. Prepare every few days.

                 3.5.4.4        Secondary Phosphorus Solution:  Take 1.0 mL of stock phosphorus standard and
                               dilute to 100 mL with reagent water (1.0 mL = 0.0010 mg P). Refrigerate and
                               keep no longer than 10 days.

                 3.5.4.5        Prepare a series of standards by diluting suitable volumes of standard solutions to
                               100 mL with reagent water. Prepare these standards daily.  When working with
                               samples of known salinity it is recommended that the standard curve
                               concentrations be prepared in substitute ocean water. When analyzing samples of
                               varying salinites, it is recommended that the standard curve be prepared in
                               deionized water and refractive index corrections be made to the sample
                               concentrations.

3.6    Sample Handling

       3.6.1      Samples are stored at -20 ± 2°C for a maximum 28 days.

3.7    Procedure

       3.7.1      If samples have not been freshly collected and are frozen, thaw the samples to room temperature.

       3.7.2      Set up the manifold as instructed by the instrument manufacturer.

       3.7.3      Allow both colorimeter and recorder to warm up for 30 minutes. Obtain a steady baseline with
                 deionized water pumping through the system, add reagents to the sample stream and after the
                 reagent baseline is steady, reset the "zero" if necessary.

       3.7.4      A good sampling rate is approximately 30 samples/hr. with a 60:60:0 sample:wash ratio.

       3.7.5      Analytical sequence:  The samples and associated QC samples and standards should be run
                 according to the following sequence.

                 3.7.5.1        Five calibration standards with concentration within the linear range of the test.

                 3.7.5.2        Two method blanks.

                 3.7.5.3        Ten - twenty CBP samples.

                 3.7.5.4        One matrix spike  sample.

                 3.7.5.5        One medium concentration calibration standard.

                 3.7.5.6        One method blank.

                 3.7.5.7        Steps 3.7.5.3 - 3.7.5.6 are repeated until all samples are analyzed or QC samples


                                                IV-27

-------
                                                                                          Chapter IV
                                                                           Water Quality Monitoring
                                                                                          August 1996


                              indicate that the system is out of control and recalibration is necessary.

                3.7.5.8       One high concentration calibration standard.

                3.7.5.9       One medium concentration calibration standard.

                3.7.5.10      One low concentration calibration standard.

      3.7.6      Calculations

                3.7.6.1       Orthophosphate concentrations are calculated from the linear regression obtained
                              from the standard curve in which the concentrations of the standards are employed
                              as the independent variables and their corresponding peak heights are the
                              dependent variables.  Need a correction for PO4 in reagent water. This is done by
                              matching the matrix with the refractive reagent.

                3.7.6.2       Refractive Index Correction For Estuarine/Coastal Systems

                              3.7.6.2.1         Obtain a second set of peak heights for all samples and
                                               standards with Refractive Reagent A being pumped through the
                                               system in place of Reagent A.  Reagent B remains the same and
                                               is also pumped through the system.  Peak heights for the
                                               refractive index correction must be obtained at the same
                                               Standard Calibration Setting and on the same colorimeter as the
                                               corresponding samples and standards (Froelich and Pilson,
                                               1978). Subtract these peak heights from the corresponding peak
                                               heights obtained reagent A.
.8     Quality Control

      3.8.1      Method detection limits (MDL): Method detection limits should be established using the
                guidelines in Chapter II, Section D.

      3.8.2      Calibration

                3.8.2.1       Linear calibration range: Calibration standards should bracket the range of CBP
                              samples.

                3.8.2.2       Correlation coefficient:  The correlation coefficient must be 0.995 or better for the
                              calibration curve to be used.

      3.8.3      Method blank:  see Chapter II, Section C.

      3.8.4      Matrix spike sample: see Chapter II, Section C.

      3.8.5      Laboratory duplicate: see Chapter II, Section C.

      3.8.6      Reference materials: The laboratory must analyze a standard reference material once a year, as
                available.

                                                IV-28

-------
                                                                                        Chapter IV
                                                                          Water Quality Monitoring
                                                                                         August 1996
3.9   References
      Froelich, P.N. and M.E.Q. Pilson. 1978. Systematic absorbance errors with Technicon AutoAnalyzer II
                 colorimeters. Water Research 12: 599-603.

      Grasshoff, K., M. Ehrhardt and K. Kremling. 1983. Methods of Seawater Analysis. Verlag Chemie, Federal
                 Republic of Germany. 419 pp.

      Thayer, G.W. 1970. Comparison of two storage methods for the analysis of Nitrogen and Phosphorus
                 fractions in estuarine water. Ches. Sci. 11:3, 155-158.

      Macdonald, R.W. and F. A. McLaughlin. 1982. The effect of storage by freezing on dissolved inorganic
                 phosphate, nitrate and reactive silicate for samples from coastal and estuarine waters. Water
                 Research. 16: 95-104.

      Murphy, I. and I.P. Riley. 1962. A modified single solution method for the determination of phosphate in
                 natural waters.  Analytica chim. Acta 27: 31-36.

      Klingamann,  E.D. and D. W. Nelson.  1976. Evaluation of methods for preserving the levels of soluble
                 inorganic phosphorus and nitrogen in unfiltered water samples. I. Environ. Qual. 5:1 42-46.
       Salley, B.A., I.G. Bradshaw and B.I. Neilson. 1986. Results of comparative studies of preservation
                 techniques for nutrient analysis on water samples. VIMS, Gloucester Point, VA., 23062. 32pp

       U.S. EPA. 1974. Methods for chemical analysis of water and wastes. Methods development and quality
                 assurance research laboratory. National environmental research center. Cincinnati, Ohio 45268.

       40 CFR, [part] 136 Appendix B. Definition and Procedure for the Determination of the Method Detection
                 Limit. Revision 1.11.
                                                IV-29

-------
                                                                                         Chapter IV
                                                                           Water Quality Monitoring
                                                                                          August 1996
4.      Paniculate Phosphorus

4.1    Scope and Application

       4.1.1      This method is applicable for the determination of paniculate phosphorus in water, wastewater,
                 saline, surface, and ground waters by a semi-automated high temperature combustion, HCL
                 extraction technique in the range of 0.01 to 2.0 mg/L of P (Aspila, et al, 1976).
       Note:  Final matrix of analysis = 0.2 NHC1

4.2    Summary of Method

       4.2.1      Ammonium molybdate and antimony potassium tartrate react in an acid medium with dilute
                 solutions of phosphorus to form an antimony-phospho-molybdate complex. This complex is
                 reduced to an intensely blue-colored complex by ascorbic acid.  The color is proportional to the
                 phosphorus concentration.

4.3    Interferences

       4.3.1      Silicon at a level of 100 • g/L causes an interference equivalent to approximately 0.04 • g/L of
                 P/L. This can be avoided by maintaining an acid concentration of 2.45N H2SO4 in the reagents
                 and analysis at 37 ± 2°C.

4.4    Apparatus and Materials

       4.4.1      Continuous flow automated analytical system equipped with an  autosampler, manifold,
                 proportioning pump, colorimeter, phototube, recorder or computer based data system, and
                 heating bath.  Add a dilution coil to automatically dilute the sample to 10% with reagent water
                 for orthophosphate analysis as per subsection 3.

       4.4.2      Appropriate glassware, see section 1.8

                 NOTE: Clean all glassware two times with 4N HC1 and rinse 9 times with reagent water.

       4.4.3      Autoanalyzer cups, see section 1.8.3

       4.4.4      Muffle furnace capable of maintaining temperatures 550 ± 50°C.

       4.4.5      Whatman 47 mm glass fiber filter (0.7 • m pore size).

       4.4.6      Centrifuge tubes, 50 mL capacity.

       4.4.7      Filter apparatus with a minimum of 100 mL capacity.

4.5    Reagents

       4.5.1      Reagent Grade Water: see section 1.9.
                                                 IV-30

-------
                                                                                        Chapter IV
                                                                          Water Quality Monitoring
                                                                                         August 1996


       4.5.2      Hydrochloric Acid, IN: In a one-liter volumetric flask, add approximately 800 mL of reagent
                 water.  Add 86 mL of concentrated HC1 and dilute to one liter with reagent water.

       4.5.3      Sulfuric Acid, 5.ON: To a one-liter volumetric flask, add 400 mL of reagent water. Add 140 mL
                 of concentrated H2SO4, mix, cool, and dilute to one liter with reagent water.

       4.5.4      Potassium Antimony Tartrate Solution:  In a one-liter volumetric flask, add 800 mL of reagent
                 water.  Add 3.0 g of K(SbO)C4H4O6*y2H2O, dissolve, and dilute to volume with reagent water.
                 Store in a glass-stoppered bottle at room temperature.

       4.5.5      Ammonium Molybdate Solution:  In a one-liter volumetric flask, add 800 mL of reagent water.
                 Add 40.0 g of ammonium molybdate  (NH4)(iMo7O24<4H2O, dissolve, and dilute to volume with
                 reagent water. Store in a plastic bottle at 4 ± 2°C away from direct sunlight.

       4.5.6      Ascorbic Acid:  In a one-liter volumetric flask, add 800 mL of reagent water. Add 18.0 g of
                 ascorbic acid, dissolve, and dilute to one liter with reagent water.  Dispense 40 mL into clean
                 polybottle and freeze.  Thaw overnight in the refrigerator before use.

       4.5.7      Sodium Lauryl Sulfate Solution:  In a 100-mL volumetric flask, add 80 mL of reagent water.
                 Add 3.0 g of sodium lauryl sulfate, dissolve, and dilute to 100-mL with reagent water.

       4.5.8      Working reagent:

                 4.5.8.1       Reagent A: In a 100-mL volumetric flask, add 50 mL of 4.9N H2SO4, 5 mL of
                              potassium antimony tartrate solution, 15 mL of ammonium molybdate, and 1.0
                              mL of sodium lauryl sulfate solution.  All reagents must reach room temperature
                              before they are mixed. Add the reagents in the order given and mix the resultant
                              solution after each addition. The combined reagent is stable for 4 hours.

                 4.5.8.2       Reagent B: In a 100-mL volumetric flask, add 30 mL of ascorbic acid, and 0.3
                              mL of sodium lauryl sulfate solution.  All reagents must reach room temperature
                              before they are mixed. Add the reagents in the order given and mix the resultant
                              solution after each addition. The combined reagent is stable for 4 hours.

       4.5.9      Stock Phosphate Standard Solution: In a one-liter volumetric flask, add 500 mL of reagent water.
                 Add 1.632 g of anhydrous potassium  dihydrogen phosphate (KH2PO4) that has been dried
                 overnight at 105 ± 2°C (stored in a desiccator), dissolve, and dilute to volume with reagent water.
                 Add 1.0 mL of chloroform as a preservative. This solution is only stable for  six months at 4 ±
                 2°C. (1.0 mL= 12.0 »gP)

4.6    Sample Handling

       4.6.1      Samples are stored at -20 ± 2°C for a  maximum 28 days.

4.7    Procedure

       4.7.1      Sample preparation:
                                                IV-31

-------
                                                                                    Chapter IV
                                                                     Water Quality Monitoring
                                                                                     August 1996
           4.7.1.1       Record the weight of the GF/F filter used for total suspended solids after the total
                        suspended solids have been determined and muffle for PP or refreeze them.

           4.7.1.2       Remove the filters from the freezer and store in a clean container and dry
                        overnight in an oven at 50 ± 2°C.

           4.7.1.3       Place the dried filters in a clean numbered crucible in a muffle furnace and heat
                        for 2 hours at 550 ± 2°C. Cool overnight.
4.7.2       Place the filters in labelled 50-mL plastic screw cap centrifuge tubes, add 10 mL of IN HC1, cap
           and shake gently, several times during a 24-hour period. Dilute to 50 ml with reagent water and
           measure phosphate concentration.

4.7.3       Transfer the supernatant extract to autoanalyzer cups with a Pasteur pipette, and prepare to
           measure the phosphate concentration

4.7.4       Allow both the colorimeter and recorder to warm up for 30 minutes.  Obtain a stable baseline
           with all reagents, feeding reagent water through the sample line.

4.7.5       Prepare a series of standard solutions covering the concentration range of the samples by diluting
           either the stock or standard solutions with substitute ocean water.

4.7.6       Analytical sequence: The samples and associated QC samples and standards should be run
           according to the following sequence.

           4.7.6.1       Five calibration standards with concentration within the linear range of the test.

           4.7.6.2       Two method blanks.

           4.7.6.3       Ten-twenty CBP samples.

           4.7.6.4       One matrix spike sample.

           4.7.6.5       One medium concentration calibration standard.

           4.7.6.6       One method blank.

           4.7.6.7        Steps 4.7.6.3 - 4.7.6.6 are repeated until  are samples are analyzed or QC samples
                        indicate that the system is out of control  and recalibration is necessary.

           4.7.6.8       One high concentration calibration standard.

           4.7.6.9       One medium concentration calibration standard.

           4.7.6.10      One low concentration calibration standard.

4.7.7       Switch sample line from distilled water to  sampler and begin analysis.

                                           IV-32

-------
                                                                                          Chapter IV
                                                                           Water Quality Monitoring
                                                                                          August 1996


       4.7.8      Prepare appropriate standard curve by plotting peak heights of processed standards made up with
                 KH2PO4, in a 0.2N Hcl matrix, against known concentrations. Compute concentration of the
                 samples by comparing sample peak heights with standard curve.

                 NOTE: Subtract the blank background response from the standards before preparing the
                 standard curve.

       4.7.9      Record the stabilized potential of each unknown sample and convert the potential reading to the
                 phosphorus concentration using the standard curve.

4.8    Quality Control

       4.8.1      Method detection limits (MDL): Method detection limits should be established using the
                 guidelines in Chapter II, Section D.

       4.8.2      Calibration

                 4.8.3         Linear calibration range: Calibration standards should bracket the range of CBP
                               samples.

                 4.8.3.1        Correlation coefficient:  The correlation coefficient must be 0.99 or better for the
                               calibration curve to be used.

       4.8.4      Method blank:  see Chapter II, Section C.

       4.8.5      Matrix spike sample: see Chapter II, Section C.

       4.8.6      Laboratory duplicate: see Chapter II, Section C.


       4.8.7      Reference materials: The laboratory must analyze a standard reference material once a year, as
                 available.

4.9    References

       Aspila, K.I., H Agemianand A.S.Y. Chau. 1976. A semi-automated method            for the
determination of inorganic, organic, and total phosphate               in sediments analysis. 101:187-197.


       Standard Methods for the Examination of Water and Wastewater, 14th           Edition, p 1193.

       Annual Book of ASTM Standards,  Part 31, "Water", Standard D 515-72, p 389 (1976).

       Standard Operating Procedures for  Nutrient Analytical Services Laboratory, Chesapeake Biological
                 Laboratory, May 1988.
                                                 IV-33

-------
                                Chapter IV
                    Water Quality Monitoring
                                August 1996
IV-34

-------
                                                                   Chapter IV
                                                        Water Quality Monitoring
                                                                    August 1996
Orthophosphate/Total Dissolved Phosphporus/Particulate Phosphorus

                            SKALAR SAN plus System
                  ml/min
 Mixed Reagent
  Air
              0.23
              0.23
  Sample       •
  Distilled Water  L
  + FFD6
              0.8
              0.32
     Sampler
              0.8
5246
                       WASTE
521Q/
      5325
5325
                        WASTE
                                                    40oC
                                                           Flow Cell 50* mn
                                                           Filter 880 nm
                                                           Cor. Filter 1010 rim
                                                       turbo flow cell catnr. SA 6275
                                     IV-35

-------
                                                                                         Chapter IV
                                                                           Water Quality Monitoring
                                                                                          August 1996


5.      Nitrite

5.1     Scope and Application

       5.1.1      This method provides a procedure for the determination of low level nitrite concentrations
                 normally found in estuarine and/or coastal waters.

       5.1.2      A method detection limit (MDL) of 0.0002 mgN/L has been statistically determined by one
                 laboratory. This MDL is defined as three times the standard deviation of at least seven replicates
                 of a low level estuarine (~15 parts per thousand salinity) sample. The method is linear to 0.070
                 mg N/L at a standard calibration setting of 9.0 on an AutoAnalyzer II system. Where higher
                 concentrations are encountered, the method is also linear at less sensitive standard calibration
                 settings.

       5.1.3      This method should be used by analysts experienced in the use of automated colorimetric
                 analyses, matrix interferences and procedures for their correction. A minimum of six months
                 experience under supervision is recommended.

5.2     Summary of Method

       5.2.1      This method is an automated colorimetric method for the analysis of low level nitrite
                 concentrations.  Filtered samples are analyzed by deoxidizing with sulfanilamide and coupling
                 with N-1-naphthylethylenediamine dihydrochloride to form a colored azo dye. The color
                 produced is proportional to the nitrite concentration present in the sample.

5.3     Interferences

       5.3.1      Metal ions may produce a positive error if present in sufficient concentrations.

       5.3.2      Sample turbidity should be removed by filtration prior to analysis.

       5.3.3      Refractive Index interferences should be corrected for when analyzing estuarine/coastal samples.

5.4     Apparatus and Materials

       5.4.1      Continuous flow automated analytical system equipped with an autosampler, manifold,
                 proportioning pump, colorimeter, phototube or recorder or computer based data system.

       5.4.2      Nitrogen-free glassware: All glassware used in the determination must be low in residual nitrite
                 to avoid sample/reagent contamination. Washing with 10% HC1 and thoroughly rinsing with
                 reagent water has been found to be effective.

5.5     Reagents

       5.5.1      Stock reagent solutions

                 5.5.1.1       Ammonium Chloride Reagent: Dissolve 10.0 g of ammonium chloride (NH4Cl)in
                              one liter of reagent water.  Adjust to pH 8.5 by adding three to four NaOH pellets

                                                 IV-36

-------
                                                                                               Chapter IV
                                                                                Water Quality Monitoring
                                                                                                August 1996


                                    as necessary.  Add 5 drops of 2% copper sulfate solution. No addition of EDTA
                                    is necessary. This reagent is stable for one week if kept refrigerated.

                      5.5.1.2        Color Reagent:  Combine 1500 mL reagent water, 200.0 mL concentrated
                                    phosphoric acid (H3PO4), 20.0 g sulfanilamide, and 1.0 g N-l
                                    napthylethylenediamine dihydrochloride. Dilute to 2000 mL with reagent water.
                                    Add 2.0 mL BRIJ-35 (Bran & Luebbe, Elmsford, N.Y.).Store at 4 ± 2°C in the
                                    dark. This should be prepared every six weeks.

                      5.5.1.3        Refractive Reagent:  Combine 100 mL of concentrated phosphoric acid (H3PO4)
                                    with 800 mL reagent water. Dilute to 1000 mL with reagent water. Add 1.0 mL
                                    BRIJ-35.

                      5.5.1.4        Stock Nitrite Solution: Dissolve 0.493 g pre-dried (60 ± 2°C for 1 hour) sodium
                                    nitrite (NaNO2) in reagent water and dilute to 1000 mL. 1.0 mL = 0.100 mg N.
                                    The stability of this stock standard is approximately 3 months, if kept refrigerated.

            5.5.2      Reagent water: see section 1.9

            5.5.3      Artificial Sea Water: see section 1.7

            5.5.4      Secondary Nitrite Solution: Dilute  1.0 mL of stock nitrite solution to 100 mL with reagent water.
                      1.0 mL  of this solution =  0.001 mg N.  Refrigerate and store no longer than 3 days.

            5.5.5      Prepare a series of standards by diluting suitable volumes of secondary nitrite solution to 100 mL
                      with reagent water. Prepare these standards daily.  When working with samples of known
                      salinity  it is recommended that the standard curve concentrations be prepared in substitute ocean
                      water diluted to that salinity and that the sampler wash solution also be substitute ocean water
                      diluted to that salinity.  When analyzing samples of varying salinities, it is recommended that the
                      standard curve be prepared in reagent water and Refractive Index corrections be made to the
                      sample  concentrations. The following dilutions, brought up to 100 mL with reagent water, are
                      suggested.

                mL of standard nitrite solution                                Concentration (mg N/L)
                            0.5                                                     0.005
                            1.0                                                     0.010
                            2.0                                                     0.020
                            4.0                                                     0.040
                            6.0                                                     0.060

       5.5.6       Saline nitrite  standards:  When analyzing samples of varying salinities, it is also recommended that
                  standards be prepared in a series of salinities in order to quantify the "salt error," the shift in the
                  colorimetric response of nitrite due to the change in the ionic strength of the solution.

5.6    Sample Handling

       5.6.1       Samples must be analyzed as quickly as possible. If the  samples are to be analyzed within 24 hours of
                  collection, then refrigeration at 4 ± 2°C is acceptable.

                                                   IV-37

-------
                                                                                                Chapter IV
                                                                                 Water Quality Monitoring
                                                                                                August 1996


       5.6.2       If samples will not be analyzed within 24 hours of collection, the sample must be stored at -20 ± 2°C
                  for a maximum of 28 days.
5.7    Procedure
       5.7.1       Calibration:  Standard curves of varying concentrations should be analyzed through several standard
                  calibration settings (calibrated sensitivity settings).  In so doing, where higher concentrations are
                  encountered, the method will also have been checked for linearity using sets of standards of higher
                  concentrations.

       5.7.2       Sample analysis

                  5.7.2.1       If samples have not been freshly collected and are frozen, thaw the samples to room
                               temperature.

                  5.7.2.2       Allow both colorimeter and recorder to warm up for 30 minutes.  Obtain a steady
                               baseline with reagent water pumping through the system, add reagents to the sample
                               stream and after the reagent base line is steady, reset the "zero" if necessary.

                  5.7.2.3       A good sampling rate is approximately 40 samples/hr. with a 9:1 sample:wash ratio.

                  5.7.2.4       Analytical sequence: The samples and associated QC samples and standards should be
                               run according to the following sequence.

                               5.7.2.4.1        Five calibration standards with concentration within the linear range
                                               of the test.

                               5.7.2.4.2        Two method blanks.

                               5.7.2.4.3        Ten CBP samples.

                               5.7.2.4.4        One matrix spike sample.

                               5.7.2.4.5        One medium concentration calibration standard.

                               5.7.2.4.6        One method blank.

                               5.7.2.4.7        Steps 5.7.2.4.3 - 5.7.2.4.6 are repeated until samples are analyzed or
                                               QC samples indicate that the system is out of control and
                                               recalibration is necessary.

                               5.7.2.4.8        One high concentration calibration standard.

                               5.7.2.4.9        One medium concentration calibration standard.

                               5.7.2.4.10       One low concentration calibration standard.

                  5.7.2.5       If a low concentration sample peak follows a high concentration sample peak, a certain

                                                    IV-38

-------
                                                                                                Chapter IV
                                                                                 Water Quality Monitoring
                                                                                                August 1996
                               amount of carry over can be expected. It is recommended that if there is not a clearly
                               defined low concentration peak, that the sample be reanalyzed at the end of the sample
                               run.
       5.7.3       Calculations
                  5.7.3.1       Nitrite concentrations are calculated from the linear regression obtained from the
                               standard curve in which the concentrations of the standards are entered as the
                               independent variable and their corresponding peak heights are the dependent variable.

                  5.7.3.2       Refractive Index Correction For Estuarine/Coastal Systems shall be performed in
                               accordance with procedures described in Section 6.7.3.2

                  5.7.3.3       Correction for Salt Error in Estuarine/Coastal Samples shall be performed in
                               accordance with procedures described in Section 6.7.3.3

                  5.7.3.4       Results should be reported in mg N/L.

5.8    Quality Control

       5.8.1       Method detection limits (MDL):  Method detection limits should be established using the guidelines in
                  Chapter II, Section D.

       5.8.2       Calibration

                  5.8.2.1       Linear calibration range:  Calibration standards should bracket the range of CBP
                               samples.

                  5.8.2.2       Correlation coefficient: The correlation coefficient must be 0.995 or better for the
                               calibration curve to be used.

       5.8.3       Method blank: see Chapter II, Section C.

       5.8.4       Matrix spike sample:  see Chapter II, Section C.

       5.8.5       Laboratory duplicate:  see Chapter II, Section C.

       5.8.6       Reference materials: The laboratory must analyze a  standard reference material once a year, as
                  available.


5.9 References

Froelich, P.N. and M.E.Q. Pilson. 1978. Systematic absorbance errors with Technicon AutoAnalyzer II calorimeters.
       Water Research 12: 599- 603.

       Grasshoff, K., M. Ehrhardt and K. Kremling.  1983. Methods of Seawater Analysis. Verlag Chemie, Federal
                  Republic of Germany. 419 pp.


                                                    IV-39

-------
                                                                                      Chapter IV
                                                                        Water Quality Monitoring
                                                                                       August 1996


Klingamann, E.D. and D. W. Nelson. 1976. Evaluation of methods for preserving the levels of soluble inorganic
           phosphorus and nitrogen in unfiltered water samples. J. Environ. Qual. 5:1 42-46.

Loder, T.C. and P.M. Glibert. 1977. Blank and salinity corrections for automated nutrient analysis of estuarine and
           seawaters. 7th Technicon International Congress: 48-56, Tarrytown, N.Y.

Macdonald, R.W. and F. A. McLaughlin. 1982. The effect of storage by freezing on dissolved inorganic phosphate,
           nitrate and reactive silicate for samples from coastal and estuarine waters. Water Research. 16: 95-104.

Salley, B.A., J.G. Bradshaw and B.I. Neilson. 1986. Results of comparative studies of preservation techniques for
           nutrient analysis on water samples. VIMS, Gloucester Point, VA., 23062. 32pp

Thayer, G.W. 1970. Comparison of two storage methods for the analysis of Nitrogen and Phosphorus fractions in
           estuarine water. Ches. Sci. 11:3, 155-158.

U.S. EPA. 1974. Methods for chemical analysis of water and wastes. Methods development and quality assurance
           research laboratory. National environmental research center. Cincinnati, Ohio 45268.

Wood, E.D., F.A.G. Armstrong and F.A. Richards.  1967. Determination of nitrate in seawaterby cadmium-copper
           reduction to nitrite. I. Mar. Biol. Assoc. U.K. 47: 23.

40 CFR, [part] 136 Appendix B. Definition and Procedure for the Determination of the Method Detection Limit.
           Revision 1.11.
                                            IV-40

-------
                                                  Chapter IV
                                          Water Quality Monitoring
                                                    August 1996
                Nitrite - Technicon AAII  Series
                             Proportioning Pump
To Sample Wash Receptacle-
             Color Reagent
                        Waste •
       50 mm Flow Cell
      COLORIMETER
       550 nm filters
Recorder
                   GRN/GRN (Water) 2.0 mL/min
                                             BLK/BLK (Air) 0.32 mL/min
                                             BLK/BLK (Air) 0.32 mL/min
                                             YEL/YEL (DIL.) 1.2 mL/min
                                                  Sampler
                                                   40/hr.
                                                    9:1
                   BLK/BLK (Sample) 0.32 mL/min

                   BLK/BLK 0.32mL/min


                   GRY/GRY (From F/C) 1.0 mL/min
                                    IV-41

-------
                                                                                               Chapter IV
                                                                                Water Quality Monitoring
                                                                                               August 1996


6.      Nitrate + Nitrite

6.1    Scope and Application

       6.1.1       This method provides a procedure for the determination of low level nitrite+nitrate concentrations
                  normally found in estuarine and/or coastal waters using the cadmium reduction technique of Wood, et
                  al., 1967.

       6.1.2       A determined method detection limit (MDL) of 0.0002 mg N/L has been statistically determined by
                  one laboratory. This MDL is defined as three times the standard deviation of at least seven replicates
                  of a low level estuarine (~15 parts per thousand salinity) sample. The method is linear to 0.070 mg
                  N/L at a standard calibration setting of 9.0 on an AutoAnalyzer II system.  Where higher
                  concentrations are encountered, the method is also linear at less sensitive standard calibration settings.

       6.1.3       This method should be used by analysts experienced in the use of automated colorimetric analyses and
                  matrix interferences and procedures for their correction. A minimum of six months experience under
                  supervision is recommended.

6.2    Summary of Method

       6.2.1       This is an automated colorimetric method for the analysis of low level nitrite+nitrate concentrations.
                  Filtered samples are passed through a granulated copper cadmium column to reduce nitrate to nitrite.
                  The nitrite originally present and the reduced nitrate are then determined by deoxidizing with
                  sulfanilamide and coupling with N-1-naphthylethylenediamine dihydrochloride to form a colored azo
                  dye. The color produced is proportional to the nitrite+nitrate concentration present in the sample.
                  Nitrite values are determined using the same method without the cadmium reduction column. Nitrate
                  values are calculated by subtracting the nitrite concentration from the previously determined
                  nitrate+nitrite value.

6.3    Interferences

       6.3.1       Concentrations of iron, copper and other metals above several milligrams per liter alter reduction
                  efficiency. The presence of large concentrations of sulfide and/or sulfate will cause a loss of
                  sensitivity to the copper-cadmium column (EPA, 1977; Grasshoff, et al., 1983).

       6.3.2       Sample turbidity should be removed by filtration prior to analysis.

       6.3.3       Refractive Index and "Salt Error" interferences should be corrected for when analyzing
                  estuarine/coastal samples by using the procedures included in this method.

6.4    Apparatus and Materials

       6.4.1       Continuous flow automated analytical system equipped with an autosampler, manifold, proportioning
                  pump, colorimeter, phototube and recorder or computer based data system.

       6.4.2       Nitrogen-free glassware: All glassware used in the determination must be low in residual nitrate to
                  avoid sample/reagent contamination. Washing with 10% HC1 and thoroughly rinsing with reagent
                  water have been found to be effective.

                                                    IV-42

-------
                                                                                             Chapter IV
                                                                               Water Quality Monitoring
                                                                                             August 1996


6.5    Reagents

       6.5.1      Stock Reagent Solutions

                 6.5.1.1        Ammonium Chloride Reagent:  Dissolve 10.0 g of nitrate-free ammonium chloride
                               (NH4C1) in one liter of reagent water. Adjust to pH 8.5 by adding three to four NaOH
                               pellets as necessary. Add 5 drops of 2% copper sulfate solution. No addition of EDTA
                               is necessary.  This reagent is stable for one week if kept refrigerated.

                 6.5.1.2        Color Reagent: Combine 1500 mL reagent water, 200.0 mL concentrated phosphoric
                               acid (H3PO4), 20.0 g sulfanilamide, and 1.0 gN-1 napthylethylenediamine
                               dihydrochloride. Dilute to 2000 mL with reagent water.  Add 2.0 mLBRIJ-35 (Bran &
                               Luebbe, Elmsford, N.Y.). Store at 4 ± 2°C in the dark. This should be prepared fresh
                               every six weeks.

                 6.5.1.3        Copper Sulfate: Dissolve 2.0 g of copper sulfate (CuSO4«5H2O) in 90.0 mL of reagent
                               water.  Bring up to  100 mL with reagent water.

                 6.5.1.4        Refractive Reagent: Combine 100 mL of concentrated phosphoric acid (H3PO4) with
                               800 mL reagent water. Dilute to 1000 mL with reagent water. Add 1.0 mL BRIJ-35.

                 6.5.1.5        Stock Nitrate Solution: Dissolve 0.721 g of pre-dried (60 ± 2°C for 1 hour) potassium
                               nitrate (KNO3) in reagent water and dilute to 1000 mL. 1.0 mL = 0.100 mg N.  The
                               stability of this stock standard is approximately 3 months, if kept refrigerated.

                 6.5.1.6        Stock Nitrite  Solution: Dissolve 0.493 g pre-dried (60 ± 2°C for 1 hour) sodium nitrite
                               (NaNO2) in reagent water and dilute to 1000 mL. 1.0 mL = 0.100 mg N. The stability
                               of this stock standard is approximately 3 months, if kept refrigerated.

       6.5.2      Reagent Grade Watersee  section 1.9.

       6.5.3      Substitute Ocean Water:  see section 1.7

       6.5.4      Cadmium preparation: The following description of cadmium and the column preparation is to be
                 used as a general guideline.  Other sizes and shapes of columns  which provide equivalent results are
                 acceptable. The ultimate goal is to obtain 100% reduction of nitrate to nitrite.

                 6.5.4.1        Use good quality cadmium filings. Depending on the reductor column shape and size,
                               cadmium filings should generally be less than 0.5 mm but greater than 0.3 mm for glass
                               columns and in the  25 - 60 mesh size range for columns prepared by using flexible
                               tubing.

                 6.5.4.2        New cadmium filings should be rinsed with diethyl ether to remove dirt and grease.
                               Approximately 10 g of this cadmium is then treated with 50 mL of 6N HC1 in a 150 mL
                               beaker. Swirl VERY CAREFULLY for one minute.

                 6.5.4.3        Carefully decant the HC1 and thoroughly rinse (at least 10 times) with reagent water.
                               Decant the reagent water and add a 50 mL portion of 2% (w/v) copper sulfate solution.

                                                  IV-43

-------
                                                                                        Chapter IV
                                                                          Water Quality Monitoring
                                                                                         August 1996


                        While swirling, brown flakes of colloidal copper will appear and the blue color of the
                        solution will fade.  Decant and repeat this sequence several times until the blue color
                        does not fade and a brown colloidal precipitate forms. To avoid contact with air, from
                        this point on the fillings must be kept submerged at all times.

           6.5.4.4       Immediately wash the filings thoroughly with reagent water until all blue color is gone
                        and the supernatant is free of paniculate matter (usually a minimum of 10 rinses is
                        necessary). The filings are now ready to be packed into the column.

           6.5.4.5       Column preparation:  Fill the reductor column with ammonium chloride reagent and
                        transfer the prepared  cadmium filings to the column using a Pasteur pipette or employ
                        some other method which avoids contact of the Cd particles with air.  One end of the
                        reductor column should be plugged with glass wool.  Column shape and size varies
                        with users. Some examples include a 22 cm length of 0.110" ID tubing, a 35 cm length
                        of 0.090" ID tubing, or a 3.5" length of glass tubing.

           6.5.4.6       When the entire column is fairly well packed with granules, insert another glass wool
                        plug at the top of the  column and with reagents pumping through the system, attach the
                        column. Remember to have no air bubbles in the valve and to attach the column to the
                        intake side of the valve first.

           6.5.4.7       Check for good flow  characteristics (regular bubble pattern) after the addition of air
                        bubbles beyond the column. If the column is packed too tightly, an inconsistent flow
                        pattern will be evident. Prior to sample analysis, condition the column by pumping
                        through the sample line approximately 1 mg N (nitrate)/L for five minutes followed by
                        1 mg N (nitrite)/L for 10 minutes.

6.5.5       Secondary Nitrate Solution:  Dilute  1.0 mL of stock nitrate solution to 100  mL with reagent water. 1.0
           mL of this solution = 0.001 mg N. Refrigerate and store no longer than 3 days.

6.5.6       Prepare a series of standards by diluting  suitable volumes of secondary nitrate solution to 100 mL with
           reagent water. Prepare these standards daily. When working with samples of known salinity it is
           recommended that the standard curve concentrations be prepared in substitute ocean water diluted to
           that salinity and that the sampler wash solution also be low nutrient seawater diluted to that salinity.
           When analyzing samples of varying salinities, it is recommended that the standard curve be prepared
           in reagent water and refractive index corrections be made to the sample concentrations. The following
           dilutions, brought up to 100  mL with reagent water, are suggested.

         mL of standard nitrate solution                               Concentration (mg N/L)
                     0.5                                                     0.005
                     1.0                                                     0.010
                     2.0                                                     0.020
                     4.0                                                     0.040
                     6.0                                                     0.060

6.5.7       Saline Nitrate Standards: When analyzing samples of varying salinities, it is also recommended that
           standards be prepared in a series of salinities in order to quantify the "salt error," the shift in the
           colorimetric response of nitrate due to the change in the ionic strength of the solution.

                                             IV-44

-------
                                                                                               Chapter IV
                                                                                Water Quality Monitoring
                                                                                               August 1996


       6.5.8       Secondary Nitrite Solution: Dilute 1.0 mL of stock nitrite solution to 100 mL with reagent water.  1.0
                  mL of this solution = 0.001 mg N. Refrigerate and store no longer than 3 days.

       6.5.9       Working Nitrite Solution:  One working standard must be prepared and used as a check on the
                  reduction capability of the cadmium column. Dilute 6.0 mL of secondary nitrite solution to 100 mL to
                  yield a concentration of 0.060 mg N/L.

6.6    Sample Handling

       6.6.1       Samples must be analyzed as quickly as possible. If the samples are to be analyzed within 24 hours of
                  collection, then refrigeration at 4 ± 2°C is acceptable.

       6.6.2       If samples will not be analyzed within 24 hours of collection, the  sample must be stored at -20 ± 2°C
                  for a maximum of 28 days.

6.7    Procedure

       6.7.1       Calibration: Prepare calibration curves using calibration standards that bracket the CBP samples.

       6.7.2       Sample analysis

                  6.7.2.1        If samples have not been freshly collected and are  frozen, thaw the samples to room
                               temperature.

                  6.7.2.2        Allow both colorimeter and recorder to warm up for 30 minutes.  Obtain a steady
                               baseline with reagent water pumping through the system, add reagents to the sample
                               stream and after the reagent base line is steady, reset the "zero" if necessary.

                  6.7.2.3        A good sampling rate is approximately 40 samples/hr. with a 9:1  sample:wash ratio.

                  6.7.2.4        Analytical sequence:  The samples and associated  QC samples and standards should be
                               analyzed according to the following sequence.

                               6.7.2.4.1         Calibration standards in reagent  water and saline water and working
                                               nitrite standards in order of decreasing concentration. Two standards
                                               of each composition and concentration should be analyzed.

                               6.7.2.4.2         Two method blanks.

                               6.7.2.4.3         Ten-twenty CBP samples.

                               6.7.2.4.4         One matrix spike sample.

                               6.7.2.4.5         One medium concentration calibration standard.

                               6.7.2.4.6         One method blank.

                               6.7.2.4.7         Steps  6.7.2.4.3 - 6.7.2.4.6 are repeated until all samples are analyzed

                                                   IV-45

-------
                                                                                        Chapter IV
                                                                          Water Quality Monitoring
                                                                                         August 1996
                                         or QC samples indicate that the system is out of control and
                                         recalibration is necessary.

                        6.7.2.4.8         One standard of each composition and concentration in order of
                                         decreasing concentration.

           6.7.2.5       The peak height of the 0.060 mg N/L nitrate standard prepared in deionized water must
                        be equal to or greater than 90% of the peak height of the 0.060 mg N/L nitrite standard.
                        If this criteria is not met, a fresh cadmium reduction column must be prepared and
                        checked before any CBP samples may be analyzed.

           6.7.2.6       If a low concentration sample peak follows a high concentration sample peak, a certain
                        amount of carry over can be expected.  It is recommended that if there is not a clearly
                        defined low concentration peak, that the sample be reanalyzed.
6.7.3       Calculations
           6.7.3.1       Concentrations of nitrite+nitrate are calculated from the linear regression obtained from
                        the standard curve in which the concentrations of the standards are entered as the
                        independent variable and their corresponding peak heights are the dependent variable.

           6.7.3.2       Refractive Index Correction For Estuarine/Coastal Systems

                        6.7.3.2.1         The absorbance peak obtained by an automated system for nitrate in a
                                         seawater sample (when compared to a reagent [deionized] water
                                         baseline) represents the sum of absorbances from at least four
                                         sources: (1) the light changes due to the differences in the index of
                                         refraction of the seawater and reagent water;  (2) reaction products
                                         (e.g., precipitates) of BRII-35 and the seawater; (3) the absorbance of
                                         colored substances dissolved in the sample; and (4) reaction products
                                         of the nitrite and the nitrate (reduced to nitrite by the cadmium
                                         column) in the  sample with the color reagent (Loder and Glibert,
                                         1977). The first three sources of color are corrected for by the
                                         refractive index correction described here.

                        6.7.3.2.2         Obtain a second set of peak heights for all samples and standards
                                         with refractive  reagent being pumped through the system in place of
                                         color reagent.  All other reagents remain the same. Peak heights for
                                         the refractive index correction must be obtained at the same standard
                                         calibration setting and on the same colorimeter as the corresponding
                                         samples and standards  (Froelich and Pilson, 1978).  Subtract these
                                         peak heights form the corresponding peak heights obtained with the
                                         color reagent.

           6.7.3.3       Correction for Salt Error in Estuarine/Coastal Samples

                        6.7.3.3.1         When calculating concentrations of samples of varying salinities from
                                         standards prepared in reagent water, it is necessary to first correct for

                                             IV-46

-------
                                                                                               Chapter IV
                                                                                 Water Quality Monitoring
                                                                                                August 1996


                                               Refractive Index errors, then correct for the "Salt Error" alteration in
                                               color development due to the ionic strength of the samples.

                               6.7.3.3.2        Use the CBPO software to generate a line with the salinity of the
                                               saline standards as the independent variable  (X variable) and the
                                               apparent concentration of nitrate (mg N/L) from the peak height
                                               corrected for refractive index as the dependent variable (Y variable)
                                               for all 0.060 mg N/L standards.  The concentrations of the samples of
                                               known salinity are corrected for the color enhancement due to Salt
                                               Error using the resulting regression.

                  6.7.3.4       Results should be reported in mg N/L.

6.8    Quality Control

       6.8.1       Method detection limits (MDL): Method detection limits should be established using the guidelines in
                  Chapter II, Section D.

       6.8.2       Calibration

                  6.8.2.1       Linear calibration range:  Calibration standards should bracket the range of CBP
                               samples.

                  6.8.2.2       Correlation coefficient: The correlation coefficient must be 0.99 or better for the
                               calibration curve to be used.

       6.8.3       Method blank: see Chapter II, Section C.

       6.8.4       Matrix spike sample:  see Chapter II, Section C.

       6.8.5       Laboratory duplicate: see Chapter II, Section C.

       6.8.6       Reference materials: The laboratory must analyze a standard reference material once a year, as
                  available.

6.9    References

       Froelich, P.N. and M.E.Q. Pilson. 1978. Systematic absorbance errors with Technicon AutoAnalyzer II
                  calorimeters. Water Research 12:  599- 603.

       Grasshoff, K., M. Ehrhardt and K. Kremling.  1983. Methods of Seawater Analysis. Verlag Chemie, Federal
                  Republic of Germany. 419 pp.

       Klingamann, E.D. and D. W. Nelson. 1976. Evaluation of methods for preserving the levels of soluble inorganic
                  phosphorus and nitrogen in unfiltered water samples. I. Environ.  Qual. 5:1 42-46.

       Loder, T.C. and P.M. Gilbert.  1977. Blank and salinity corrections for automated nutrient analysis of estuarine and
                  seawaters. 7th Technicon International Congress: 48-56, Tarrytown, N.Y.

                                                    IV-47

-------
                                                                                      Chapter IV
                                                                       Water Quality Monitoring
                                                                                      August 1996


Macdonald, R.W. and F. A. McLaughlin. 1982. The effect of storage by freezing on dissolved inorganic phosphate,
          nitrate and reactive silicate for samples from coastal and estuarine waters. Water Research.  16: 95-104.

Salley, B.A., J.G. Bradshaw and B.J. Neilson. 1986. Results of comparative studies of preservation techniques for
          nutrient analysis on water samples. VIMS, Gloucester Point, VA., 23062. 32pp

Thayer, G.W. 1970. Comparison of two storage methods for the analysis of Nitrogen and Phosphorus fractions in
          estuarine water. Ches. Sci. 11:3, 155-158.

U.S. EPA. 1974. Methods for chemical analysis of water and wastes. Methods development and quality assurance
          research laboratory. National environmental research center. Cincinnati, Ohio 45268.

Wood, E.D., F.A.G. Armstrong and F.A. Richards. 1967. Determination of nitrate in seawaterby cadmium-copper
          reduction to nitrite. I. Mar. Biol. Assoc. U.K. 47: 23.

40 CFR, [part] 136 Appendix B. Definition and Procedure for the Determination of the Method Detection Limit.
          Revision 1.11.
                                            IV-48

-------
                                              Chapter IV
                                      Water Quality Monitoring
                                               August 1996
    Nitrate + Nitrite - Technicon AAII Series
                               Proportioning Pump
To Sample Wash Receptacle
              Color Reagent
                         Waste •
        50 mm Flow Cell
      COLORIMETER
        550 nrn filters
Recorder
                    GRN/GRN (Water) 2.0 mL/min
                                               BLK/BLK (Air) 0.32 mL/min
                                               BLK/BLK (Air) O.32 mL/min
                                               YEL/YEL (DIL.) 1.2 mL/min
                                                     Sampler
                                                     40/hr.
                                                      9:1
                    BLK/BLK (Sample) 0.32 mL/min

                    BLK/BLK 0.32mL/min


                    GRY/GRY (From F/C) 1.0 mL/min
                                IV-49

-------
                                                                                              Chapter IV
                                                                               Water Quality Monitoring
                                                                                              August 1996


7.      Ammonia

7.1     Scope and Application

       7.1.1      This method covers the determination of ammonia in water by the automated phenate method in the
                 range of 0.01 to 2.0 mg/L of NH4.

7.2     Summary of Method

       7.2.1      Alkaline phenol and hypochlorite react with ammonia to form indophenol blue.  The color intensity of
                 indophenol blue is proportional to the ammonia concentration.  By adding sodium nitroprusside to the
                 mixture, the blue color is intensified for colorimetric measurements.

7.3     Interferences

       7.3.1      Precipitation problems can occur if calcium and magnesium ions are present in sufficient amounts.  A
                 sodium potassium tartrate solution should be used to prevent this effect.

7.4     Apparatus and Materials

       7.4.1      Continuous flow automated analytical system equipped with an autosampler, manifold, proportional
                 pump, colorimeter, phototube, recorder or computer based data system, and heating bath.

       7.4.2      Appropriate glassware, see section 1.7

                 NOTE: Clean all glassware with soap and tap water, then rinse two times with 4N HC1 and rinse 9
                 times with reagent water.

       7.4.3      Autoanalyzer cups,  see section 1.7.3

7.5     Reagents

       7.5.1      Reagent Water: see section 1.9

       7.5.2      Complexing Reagent:  To a one-liter volumetric flask, add approximately 750 Ml of reagent water.
                 Dissolve 33 g of potassium sodium tartrate (KNaC4H4O(5<4H2O) and 24 g of sodium citrate
                 [HOC(COONa)(CH2COONa)2^H2O]. Adjust the pH of this solution to 5.0 with concentrated sulfuric
                 acid (H2SO4). Dilute to one liter with reagent water. Store at 4 ± 2°C.

       7.5.3      Sodium Nitroprusside:  Add approximately 900 mL of reagent water to a one-liter volumetric flask.
                 Dissolve 0.5 g of sodium nitroprusside (Na2Fe(CN)5NO*?H2O) and dilute to  one liter with reagent
                 water. Add Brij-35 only if necessary. Store in a dark bottle at 4 ± 2°C.

       7.5.4      Sodium Hypochlorite Solution: To a one-liter volumetric flask, add 400 mL of reagent water.  Add
                 200 mL of a stock sodium hypochlorite solution containing 5.25% of chlorine (NaOCl) and dilute to
                 one liter with reagent water. Add 6 drops of Brij-35. This solution is stable  for one week if stored at
                 room temperature.
                                                   IV-50

-------
                                                                                            Chapter IV
                                                                              Water Quality Monitoring
                                                                                             August 1996


       7.5.5      Alkaline Phenol Solution: In a 500 mL volumetric flask, dissolve 41.5 g of phenol (C6H5OH) in
                 approximately 100 mL of reagent water. Make sure phenol is completely dissolved (it will be white
                 and cloudy). Measure out 90 mL of 20% (w/v) of NaOH solution using a graduated cylinder and mix
                 solutions.  The solution will turn clear. Dilute to 500 mL with reagent water and mix by inverting.
                 Store in amber glass bottle. This solution should be prepared daily._

                 Caution: Phenol should be prepared every few  days under a hood.  It is an extremely dangerous
                 chemical and should be handled accordingly.

       7.5.6      Artificial Sea Water: see section 1.7

       7.5.7      Wash Water: Dilute substitute ocean water to the average  salinity of the samples being analyzed.

       7.5.8      Sodium Hydroxide Solution: 20% (w/v), reagent grade.

       7.5.9      Ammonia Stock Standard Solution: In a one-liter volumetric flask, add 200 mL of reagent water.
                 Dissolve 0.3310 g of ammonium sulfate (NH4)2SO4, mix, and dilute to one liter. Add 1 mL of
                 concentrated H2SO4 as a preservative. Store at 4 ± 2°C. This solution is stable for six months.

                 7.5.9.1       Ammonia Standard Solution A: In a 100 mL volumetric flask, add 50 mL of wash
                              water solution.  Add 2 mL of stock standard solution, mix, and dilute to volume with
                              wash water solution. This solution should be prepared on the day of analysis.  (1.0 mL
                              = 1.4mgNH3-N/L)

                 7.5.9.2       Ammonia Standard Solution B: In a 100 mL volumetric flask, add 50 mL of wash
                              water solution. Add 10 mL of ammonia standard solution A, mix, and dilute to volume
                              with wash water solution.  This solution should be prepared fresh on the day of the
                              analysis. (1.0 mL = 0.14 mg NH3-N/L).

7.6    Sample Handling

       7.6.1      Samples are stored at -20 ± 2°C for a maximum 28 days.
                                                  IV-51

-------
                                                                                                Chapter IV
                                                                                 Water Quality Monitoring
                                                                                                August 1996


7.7    Procedure

       7.7.1       Allow both the colorimeter and recorder to warm up for 30 minutes. Obtain a stable baseline with
                  deionized water pumping through the system, add reagents to the sample stream, and after the reagent
                  baseline is steady, reset the "zero" if necessary.

       7.7.2       Prepare a series of standard solutions covering the concentration range of the samples by diluting
                  either the stock or standard solutions of ammonium sulfate.

       7.7.3       Analytical sequence:  The samples and associated QC samples and standards should be analyzed
                  according to the following sequence.

                  7.7.3.1       Five calibration standards with concentration within the linear range of the test.

                  7.7.3.2       Two method blanks.

                  7.7.3.3       Ten-twenty CBP samples.

                  7.7.3.4       One matrix spike sample.

                  7.7.3.5       One medium concentration calibration standard.

                  7.7.3.6       One method blank.

                  7.7.3.7       Steps 7.7.3.5 - 7.7.3.8 are repeated until are samples are analyzed or QC samples
                               indicate that the system is out of control and recalibration is necessary.

                  7.7.3.8       One high concentration calibration standard.

                  7.7.3.9       One medium concentration calibration standard.

                  7.7.3.10      One low concentration calibration standard.

       7.7.4       Use CBP software to prepare an appropriate standard curve and to calculate the concentration of NH4.
                  The blank background response should be subtracted from the standards before preparing the standard
                  curve.

7.8    Quality Control

       7.8.1       Method detection limits (MDL): Method detection limits should be established using the guidelines in
                  Chapter II, Section D.

       7.8.2       Calibration

                  7.8.2.1       Linear calibration range:  Calibration standards should bracket the range of CBP
                               samples.

                  7.8.2.2       Correlation coefficient: The correlation coefficient must be 0.99 or better for the

                                                    IV-52

-------
                                                                                            Chapter IV
                                                                              Water Quality Monitoring
                                                                                            August 1996


                              calibration curve to be used.

       7.8.3      Method blank:  see Chapter II, Section C.

       7.8.4      Matrix spike sample: see Chapter II, Section C.

       7.8.5      Laboratory duplicate:  see Chapter II, Section C.

       7.8.6      Reference materials: The laboratory must analyze a standard reference material once a year, as
                 available.
7.9   References
       Standard Methods for the Examination of Water and Wastewater, 14th Edition, p 410, Method 418A and 418B
                 (1975).

       Annual Book of ASTM Standards, Part 31, "Water", Standard D 1426-74, Method A, p 237 (1976).
                                                  IV-53

-------
                                                       Chapter IV
                                              Water Quality Monitoring
                                                         August 1996
MANIFOLD CONFIGURATION FOR AMMONIA
                                        Proportioning Pump
       Wash Water
        to Sampler
     Heating
     Bath
     37 °C
                Waste
          G
                                       Bk
                                       R
                                       O
                                       O
                                       Bk
                                       O
                                       R
Recorder
           Colorimeter
           50 mm Flow Cell
           650-660 nm filter
G
                         Bk
                          R
                         O
                         O
                        Bk
                          O
                         R
                             2.O Wash
   0.32 Air*
Sampler
 30/hr
  6:1
   0.8 Complexing Reagent
    O.42 Sample
   O.42 Phenolate
   O.32 Hypochlorite
   O.42 Nitroprusside
   0.8 Waste
                                                            * Scrubbed through
                                                            5N H2SO4
                               Lines are placed
                               in bleach in
                               order to
                               neutralize phenol
                                       IV-54

-------
                                                                                              Chapter IV
                                                                               Water Quality Monitoring
                                                                                              August 1996


      Total Dissolved Nitrogen

. 1     Scope and Application

      8.1.1      This method covers the determination of total dissolved nitrogen in estuarine water by the automated
                persulfate oxidation technique in the range of 0.01 to 2.0 mg/L of NO3+NO2-N.

.2     Summary of Method

      8.2.1      This method is a persulfate oxidation technique for nitrogen where, under alkaline conditions, all
                forms of nitrogen are oxidized to nitrite. This is followed by analysis for nitrate by an automated
                colorometric method (subsection 6). The inorganic fractions can then be subtracted from the total
                dissolved  sample to calculate the dissolved organic concentration, if desired.

.3     Interferences

      8.3.1      Metal ions may produce a positive nitrate error if present in sufficient concentrations. The presence of
                large concentrations of sulfate will cause a large loss of sensitivity to the copper-cadmium column.

      8.3.2      Turbidity  may interfere with this method if the sample has not been filtered.

.4     Apparatus and Materials

      8.4.1      Continuous flow automated analytical system equipped with an autosampler, manifold, proportional
                pump, colorimeter, phototube, recorder or computer based data system, and heating bath.

      8.4.2      Appropriate glassware,  see section 1.7

      8.4.3      Autoanalyzer cups,  see section 1.7.3

.5     Reagents

      8.5.1      Reagent Grade Water:  see section 1.9

      8.5.2      Borate Buffer Solution:  To a two liter volumetric flask, add approximately 800 mL of reagent water.
                Add 123.6 g of boric acid (H3BO3) and 16.16g of Low N sodium Hydroxide (NaOH) and dilute to two
                Liters with reagent water.  Stable for two months at room temperature.

      8.5.3      Oxidizing Reagent:  To a one-liter volumetric flask, add 400 mL of reagent water. AddS.Ogoflow
                nitrogen NaoH and 20.1 g of Baker Instra-analyzed potassium persulfate, dissolve, and dilute to one
                liter with reagent water. Store in a glass reagent bottle. This solution is only stable for two hours at
                room temperature.

      8.5.4      Ammonium Chloride Preparation Water: Measure out two liters of reagent water with a graduated
                cylinder into a clean 2-liter Erlenmeyer flask. Add a magnetic Teflon stirring bar. While  stirring the
                water, measure the pH.  Adjust the pH to 8.5 by adding one drop of ammonium hydroxide. If the
                solution becomes too acidic dilute the ammonium with water until the solution reaches a pH of 8.5.
                                                   IV-55

-------
                                                                                      Chapter IV
                                                                        Water Quality Monitoring
                                                                                      August 1996


8.5.5      Ammonium Chloride Reagent: In a two-liter volumetric flask, measure out approximately 1.5 L of
          ammonium chloride preparation water. Add 20 g of ammonium chloride (NH4C1) and 0.2 g of
          disodium EDTA, dissolve, and dilute to two liters with reagent water. Make sure the ammonium
          chloride and EDTA are completely dissolved.  Store in a glass bottle, add 1.0 mL of Brij-35, and 5
          drops of 2% copper sulfate (CuSO4) solution.

8.5.6      Color Reagent:  In a one-liter volumetric flask, add 500 mL of reagent water. Add 100 mL of
          concentrated phosphoric acid H3PO4 and 10 g of sulfanilamide (C6H8N2O2S), dissolve the mixture
          using low heat if necessary.  Add 0.5 g of N-1-naphthylethylenediamine dihydrochloride
          (C12H14N2«?HC1) and dissolve. Cool to room temperature then, dilute to one liter with reagent water.
          Pour into a plastic one-liter bottle and add 0.5 mL of Brij-35.  Store in the dark at 4 ±2°C. This
          solution is stable for one month at 4 ± 2°C.

8.5.7      Copper Sulfate Solution, 2% (w/v): In a one-liter volumetric flask, add 500 mL of reagent water. Add
          20.0 g of CuSO4, dissolve, and dilute to volume with reagent water.  Store in a plastic bottle at room
          temperature. This solution is stable for two months.

8.5.8      Phosphoric Acid, 10%: In a 500-mL volumetric flask, add 400 mL of reagent water.  Add 50 mL of
          concentrated phosphoric acid H3PO4, dissolve, and dilute to volume with reagent water. Add 0.25 mL
          of Brij-35.  Store in a ground glass-stoppered glass bottle at room temperature.

8.5.9      Artificial Sea Water: see section 1.7

8.5.10     Wash Water: Dilute substitute ocean water to the average salinity of the  samples being analyzed. Add
          4 mL of Brij-35 per liter. Make this solution daily.

8.5.11     Stock Glutamic Acid Standard:  In a 500-mL volumetric flask, add 400 mL of reagent water. Add
          0.3705 g of glutamic acid  (HOCOCH2CH2CH(NH2)COOH), mix, and dilute to volume with reagent
          water. Add 0.5  mL of chloroform (under a hood) as a preservative. This solution is only stable for ten
          months at 4 ± 2°C.

          8.5.11.1      Working Glutamic Acid Standard: In a 100-mL volumetric flask, add 50 mL of wash
                       water solution.  Add 0.5 mL of stock standard solution, mix,  and dilute to volume with
                       wash water solution. This solution should be prepared on the day of analysis. (1.0 mL
                       = .3528mgN/L)

8.5.12     Stock Nitrate Standard: In a one-liter volumetric flask, add 500 mL of reagent water. Add 0.7218 g of
          potassium nitrate (KNO3) that has been dried overnight at  103 ± 2°C (stored in a desiccator), mix, and
          dilute to volume with reagent water. Add 2 mL of chloroform (under a hood) as a preservative.  This
          solution is only  stable for six months at 4 ± 2°C.

8.5.13     Stock Nitrite Standard: In a 500-mL volumetric flask, add 400 mL of reagent water. Add0.6160gof
          sodium nitrite (NaNO2) that has been dried  overnight at 103 ± 2°C (stored in a desiccator), mix, and
          dilute to volume with reagent water. Add 2 mL of chloroform (under a hood) as a preservative.  This
          solution is only  stable for one month at 4 ±  2°C.

8.5.14     Column preparation:
                                            IV-56

-------
                                                                                             Chapter IV
                                                                               Water Quality Monitoring
                                                                                             August 1996


                 8.5.14.1      Treatment of cadmium: Approximately 7 g of cadmium are poured into a 125 mL
                              Erlenmeyer flask. Add enough IN HC1 to the flask to cover the cadmium, and swirl for
                              10 seconds (do not exceed this allotted time). Quickly rinse the cadmium with ASTM
                              type II water until the solution is non-acidic (test with pH paper). Next, add 100 mL
                              portions of 2% CuSO4 solution and swirl for 30 to 40 seconds. The cadmium will start
                              to look very  dark, the blue color will fade, and a brown colloidal precipitate forms.
                              Pour off the  2% CuSO4. Wash the cadmium-copper with reagent water (at least ten
                              times) to remove all precipitated copper. The color of the cadmium so treated should
                              be black. Add ammonium chloride reagent to the flask so that it covers the cadmium.
                              The cadmium can be capped tightly and stored this way or used immediately to make a
                              column.

                              NOTE: When a cadmium column significantly loses its efficiency, or the ammonium
                              chloride the  cadmium column is stored in appears cloudy, the column can be recleaned
                              with acid and recoated with copper sulfate according to the above directions, except
                              that it is only exposed to the copper sulfate for 15 seconds.

                 8.5.14.2      Packing the column:  Disconnect the end of the plastic tubing which connects the
                              cadmium column to the second set of mixing coils on the cartridges (farthest from the
                              column). Tape the end high enough so the ammonium chloride reagent will not leak
                              out of the column. Unscrew the column from the cartridge, fill the column with
                              ammonium chloride, pack the column by adding small amounts of the treated cadmium
                              to it and tapping the column so the cadmium is packed without allowing the air into the
                              column.

8.6    Sample Handling

       8.6.1      Samples are stored at -20 ± 2°C for a maximum 28 days.

8.7    Procedure

       8.7.1      Sample preparation:

                 8.7.1.1       To each 30 mL screw cap test tube add 10 mL filtered sample. Add 10 mL reagent
                              grade water to 3 test tubes as blanks.

                 8.7.1.2       Pipet 5.0 mL of the oxidizing reagent in all tubes. Cap test tubes tightly and very
                              quickly due to volatilization. Include two oxidizing reagent blanks which contain only
                              the oxidizing reagent.

                 NOTE:  A precipitate will form with seawater samples which will not form with saline standards
                 prepared with NaCl. If standards are made with substitute ocean water the precipitate will form.

                 8.7.1.3       Autoclave samples at 100 -110° (between 3-4 psi) for 30 minutes on the liquid
                              automatic cycle. No volatilization occurs after this point.

                 8.7.1.4       Remove tubes from autoclave and cool to room temperature (samples can be
                              refrigerated for several days at this point if necessary to delay analysis).

                                                   IV-57

-------
                                                                                        Chapter IV
                                                                          Water Quality Monitoring
                                                                                         August 1996


8.7.2       Add 1.0 mL of buffer solution to each tube. The pH of the sample should be around 2.5 after the
           addition of buffer solution.

8.7.3       Allow both the colorimeter and recorder to warm up for 30 minutes. Obtain a stable baseline with all
           reagents, feeding reagent water through the sample line.

8.7.4       Screw the column onto the cartridge. Untape the other end, and reconnect it to the color reagent line
           in the  10% phosphoric acid reagent. Once an acceptable baseline has been acquired, place the color
           reagent line into the color reagent.

8.7.5       Prepare a series of standard solutions covering the concentration range of the samples by diluting
           either the stock or standard solutions.

8.7.6       Analytical sequence:  The samples and associated QC samples and standards should be run according
           to the following sequence.

           8.7.6.1       Two high concentration calibration standards.

           8.7.6.2       Two medium concentration calibration standards.

           8.7.6.3       Two low concentration calibration standards.

           8.7.6.4       Two method blanks.

           8.7.6.5       Ten-twenty CBP samples.

           8.7.6.6       One matrix spike sample.

           8.7.6.7       One medium concentration calibration standard.

           8.7.6.8       One method blank.

           8.7.6.9       Steps 8.7.7.5 - 8.7.7.8 are repeated until are samples are analyzed or QC samples
                        indicate that the system is out of control and recalibration is necessary.

           8.7.6.10      One high concentration calibration standard.

           8.7.6.11      One medium concentration calibration standard.

           8.7.6.12      One low concentration calibration standard.

8.7.7       Switch sample line from distilled water to sampler and begin analysis.

8.7.8       Prepare appropriate standard curve by plotting peak heights of processed standards against known
           concentrations.  Compute  concentration of the samples by comparing sample peak heights with
           standard curve.

           NOTE:  Subtract the blank background response from the standards before preparing the standard

                                             IV-58

-------
                                                                                              Chapter IV
                                                                                Water Quality Monitoring
                                                                                               August 1996
                 curve.
       8.7.9      Test the cadmium column efficiency by analyzing 2 cups of the 0.4 mg NO3-N/L standard followed by
                 one cup of the 0.4 mg NO2-N/L standard. The column efficiency must be 90-110%. To ensure that
                 the nitrate standards are correct, also analyze 2 cups of the EPA standard. Complete loading of
                 sampler tray with quality control and unknown samples.

       8.7.10     Record the stabilized potential of each unknown sample and convert the potential reading to the TDN
                 concentration using the standard curve.

8.8    Quality Control

       8.8.1      Method detection limits (MDL): Method detection limits should be established using the guidelines in
                 Chapter II, Section D.

       8.8.2      Calibration

                 8.8.2.1        Linear calibration range:  Calibration standards should bracket the range of CBP
                               samples.

                 8.8.2.2        Correlation coefficient: The correlation coefficient must be 0.99 or better for the
                               calibration curve to be used.

       8.8.3      Method blank:  see Chapter II, Section C.

       8.8.4      Matrix spike sample: see Chapter II, Section C.

       8.8.5      Laboratory duplicate:  see Chapter II, Section C.

       8.8.6      Reference materials:  The laboratory must analyze a standard reference material once a year, as
                 available.

8.9    References

       Standard Methods for the Examination of Water and Wastewater, 14th Edition, p 427, Method 419D (1975).

       Annual Book of ASTM Standards, Part 31, "Water", Standard D 3867, p 453 (1976).
                                                   IV-59

-------
                                               Chapter IV
                                      Water Quality Monitoring
                                                 August 1996
MANIFOLD CONFIGURATION FOR NITRATE/TOTAL DISSOLVED NITROGEN
To Sample Wash Receptacle-
       Cadmium
       Reduction
       Column
    Colorimeter

    550 nm Filter;

    50 mmFlow Cel
                                      mL/min
                                       2.0
                                       0.32
0.32
                                       1.2
                                       0.32
                                       0.6
                                       0.32
                                       1.0
                                       Pump
      Water (GRN/GRN)
                                             Air (BLK/BLK)
      Air (BLK/BLK)
                                             NH CL (YEL/YEL)
                                             Sample (BLK/BLK)
                                             Debubbler (WHT/WHT)
                                             Color Reagent (BLK/BLK)
                                             Waste From F/C (GRY/GRY)
                              IV-60

-------
                                                                                             Chapter IV
                                                                               Water Quality Monitoring
                                                                                              August 1996


.10  Paniculate Nitrogen

. 11  Scope and Application

     8.12       This method covers the determination of paniculate nitrogen in estuarine or sea water.

. 13  Summary of Method

     8.13.1     The sample is filtered through a glass fiber filter and the filter is then placed in a combustion chamber
                for analysis.

     8.13.2     The nitrogen determination is made by burning the glass fiber filter in a closed system in the presence
                of oxygen. The nitrogen in the sample is converted to molecular nitrogen (N2) and oxides of nitrogen
                (NOX) during the combustion.  A carrier gas first transports the combustion products to a reduction
                tube where the NOX is converted to N2, and then to a thermal conductivity detector for measurement.

. 14  Apparatus and Materials

     8.14.1     Carlo Erba NA 1500 Nitrogen/Carbon Analyzer, or other instrumentation.

     8.14.2     Clean metal forceps.

     8.14.3     Plastic syringe, 60 mL.

     8.14.4     Filter holders with O-rings, 13 mm.

     8.14.5     Dichromic acid washed DOC bottle.

     8.14.6     Dichromic acid washed 50 mL graduated cylinder.

     8.14.7     Glass transfer pipettes.

     8.14.8     Desiccator.

     8.14.9     Glass fiber filters, mm diameter, with a nominal pore size of 0.7 • m.

  8.14.10        Muffle oven.

  8.14.11        Analytical balance.

.15  Reagents

     8.15.1     Cleaning Solvents



                8.15.1.1       Reagent Grade Water: see section 1.9.
                                                  IV-61

-------
                                                                                              Chapter IV
                                                                               Water Quality Monitoring
                                                                                              August 1996


. 16   Sample Handling

      8.16.1     Filter preparation

                8.16.1.1       Whatman glass fiber filters, or equivalent, are placed in a metal crucible, loosely
                              arranged.

                8.16.1.2       Place filters in muffle ovenfor 1.5 hours at 550°C.

                8.16.1.3       Remove from muffle oven, and cover crucible with aluminum foil until cool.

                8.16.1.4       Place muffled filters in clean labeled petri dishes until use.

      8.16.2     Sample preparation

                8.16.2.1       Remove foil pouches containing sample filters from freezer and open them.

                8.16.2.2       Put foil pouches in drying oven at 50 ± 1°C overnight.

                8.16.2.3       Next day, remove foil pouches from oven, fold closed and desiccate until ready for
                              analysis.

                8.16.2.4       Clean the metal forceps, and ANA metal sealing tray using reagent water and a
                              kimwipe. Never use acid on metal.

                8.16.2.5       Using metal forceps, place a clean tin cup in filter loading devise.

                8.16.2.6       With metal forceps remove glass fiber filter (sample) from the foil pouch, place in tin
                              cup

                8.16.2.7       Place sample in nickel sleeve into auto sampler wheel an desicate until analysis.

.17   Procedure
      8.17.1     Standards and Standard Curve Equipment Preparation

                8.17.1.1       Tin cups must always be handled with clean metal forceps.  The forceps, metal ANA
                              sealing plate and metal spatula must be rinsed with fresh reagent water and completely
                              dried with Kimwipes. Always work on a clean aluminum foil-covered surface
                              whenever handling standards or samples.

                8.17.1.2       Calibrate the electronic microbalance at the 200 mg range each day prior to weighing
                              any standards.

      8.17.2     Standardization
                                                  IV-62

-------
                                                                                       Chapter IV
                                                                         Water Quality Monitoring
                                                                                        August 1996


           8.17.2.1      For PN analysis of glass fiber filters, Chloramine-T (N-chloro-p-toluenesulfonamide
                        sodium salt) or other suitable standards are used as the standard. Standards should
                        weigh approximately 0.05 to 2.0 mg.

           8.17.2.2      Using metal forceps to handle tin cups, weigh a clean tin cup (see cleaning procedure,
                        1.7.1) on calibrated microbalance, and tare the balance to eliminate the weight of the
                        cup from the weight measurement.

           8.17.2.3      Apply balance brake and remove cup.  Place cup on clean ANA metal sealing plate and
                        unfold cup somewhat.

           8.17.2.4      Using a clean metal spatula, place approximately 0.05 to 2.0 mg Chloramine T into cup
                        and, using forceps (2 pairs), seal tin cup.

           8.17.2.5      Place sealed standard on microbalance, weigh, and record weight on data sheet.

           8.17.2.6      For the standard curve, 3 blanks (empty clean tin cups), then 7 Chloramine T standards
                        of known weight are analyzed on the Carlo Erba C/N analyzer in conjunction with the
                        Carlo Erba E. A.G.E.R. computer software.

           8.17.2.7      Chloramine T standards in the standard curve are analyzed as STD sample types and
                        CHLOR-T standard types. Blanks are analyzed as BLANK sample types.

           8.17.2.8      If the correlation coefficient for the standard curve is below the minimum acceptable
                        value, up to 2 standards and/or 1 blank may be omitted from the standard curve
                        (minimum of 2 blanks and 5 standards are required for a standard curve). A standard
                        can be omitted by bypassing the standard in the sample table and recalculating the
                        curve.

8.17.3      Analysis of Glass Fiber Filter Samples

           8.17.3.1      Set flow rates as outlined in the Carlo Erba NA 1500 Nitrogen/Carbon Analyzer
                        Instruction Manual. Set control panel parameters as follows:

                                        Filament temperature              190°C
                                        Oxygen injection stop      67 seconds
                                        Peak enable                       10 seconds
                                        Cycle stop                        410 seconds
                                        (this may need to be increased if carbon peak on Chromatogram is
                                        not completed during cycle time).

           8.17.3.2      Set autosampler tray with space #1 aligned with window on the front of the
                        autosampler.

           8.17.3.3      Place blanks and standards in spaces 1-10 of autosampler tray and, using the Carlo Erba
                        E.A.G.E.R. computer software,  generate the standard curve.

           8.17.3.4      After an acceptable standard curve has been generated, place one wrapped sample or

                                            IV-63

-------
                                                                                             Chapter IV
                                                                              Water Quality Monitoring
                                                                                             August 1996


                              standard in each space of the autosampler tray and, using the E.A.G.E.R. software, and
                              analyze the samples.

                8.17.3.5       In order to demonstrate that the instrument was still in calibration at the end of the
                              analytical run, the last sample analyzed in any series of analyses must be a standard.

                8.17.3.6       Samples will have a known volume of sample water filtered onto them. Divide that
                              volume (in mL) by 10, and place this value in the sample weight column of the sample
                              table of the E.A.G.E.R. file.

                8.17.3.7       The cycle time used in the E.A.G.E.R. program parameters should be 10 seconds longer
                              than the cycle stop time set on the C/N analyzer instrument panel.

.18  Quality Control

     8.18.1     The correlation coefficient of the calibration curve must • "0.990.

     8.18.2     Run a duplicate of each sample, and a Chloramine T standard after every 5 samples (sample and it's
                duplicate count as one sample). If the samples are not all analyzed in duplicate, a minimum of one
                duplicate must be analyzed after every 10 samples, and at least 2 duplicates must be  analyzed per
                analytical run.

     8.18.3     The calibration check standards are analyzed as unknown sample types. Recovery must be within 90-
                110% of actual value.  If recovery of a standard falls outside these limits, it is considered to be "out-of-
                control," and all samples analyzed after the last "in-control" standard must be reanalyzed.

     8.18.4     Prepare and analyze at least two standards (2 "in-control" standards must occur consecutively before
                proceeding with analyses).

     8.18.5     Re-prepare and reanalyze each sample which was analyzed after the last "in-control" standard.
                                                  IV-64

-------
                                                                                               Chapter IV
                                                                                Water Quality Monitoring
                                                                                               August 1996


9.      Paniculate Carbon

9.1    Scope and Application

       9.1.1       This method covers the determination of paniculate carbon in estuarine or sea water.

9.2    Summary of Method

       9.2.1       The sample is filtered through a glass fiber filter and the filter is then placed in a combustion chamber
                  for analysis.

       9.2.2       The carbon determination is made by burning the glass fiber filter in a closed system in the presence of
                  oxygen.  The carbon in the sample is converted to carbon dioxide during the combustion.  A carrier
                  gas then transports the CO2 to a thermal conductivity detector for measurement.

9.3    Apparatus and Materials

       9.3.1       Carlo Erba NA 1500 Nitrogen/Carbon Analyzer, or other instrumentation.

       9.3.2       Clean metal forceps.

       9.3.3       Plastic syringe, 60 mL.

       9.3.4       Filter holders with O-rings, 13 mm.

       9.3.5       Hydrochloric acid washed DOC bottle.

       9.3.6       Hydrochloric acid washed 50 mL graduated cylinder.

       9.3.7       Glass transfer pipettes.

       9.3.8       Desiccator.

   9.3.9           Muffle oven.

   9.3.10          Analytical balance.

9.4    Reagents

       9.4.1       Reagent Grade Water: see section 1.9.

9.5    Sample Handling

       9.5.1       Filter preparation


NOTE:
                  9.5.1.1       Whatman glass fiber filters are placed on aluminum foil in a muffle pan.  Filters should

                                                   IV-65

-------
                                                                                              Chapter IV
                                                                                Water Quality Monitoring
                                                                                               August 1996


                               not be touching each other.

                 9.5.1.2        Place filters in muffle ovenfor 15 minutes at 550°C.

                 9.5.1.3        Remove from muffle oven, and cover pan with aluminum foil until cool.

                 9.5.1.4        Wrap muffled filters in aluminum foil and desiccate until use.

       9.5.2      Sample preparation

                 9.5.2.1        Remove foil pouches containing sample filters from freezer.  Remove caps from foil
                               pouches and place caps and foil pouches in muffle pan.

                 9.5.2.2        Put vials in oven at 50 ± 1°C overnight.

                 9.5.2.3        Next day, remove foil pouches from oven, recap tightly, place foil pouches in divided
                               cardboard box and desiccate until ready for analysis.

                 9.5.2.4        Clean the metal forceps, and ANA metal sealing tray using reagent water and a
                               Kimwipe.  Never use acid on metal.

                 9.5.2.5        Using metal forceps, place a clean tin cup in hole #2 of ANA metal sealing tray, and
                               fan the top edges of the cup around edges of hole.

                 9.5.2.6        With metal forceps remove glass fiber filter (sample) from the glass vial, place in tin
                               cup, seal cup using forceps (2 pair), and form into a ball which should be small enough
                               to drop through the hole in the Carlo Erba C/N analyzer autosampler.

                 9.5.2.7        Replace  foil-wrapped sample into the glass vial, recap, and desiccate until analysis.

9.6    Procedure

       9.6.1      Cleaning C/N analyzer  tin cups

                 NOTE: Use the following procedure only if you have unusual contamination.

                 9.6.1.1        Pour approximately 50 mL of chloroform/methanol cleaning solution into a 100 mL
                               glass beaker.  (Level of solution in beaker should allow tin cups standing upright to be
                               completely submerged.)

                 9.6.1.2        Using clean metal forceps, submerge each cup individually into the
                               chloroform/methanol solution and stand cup upright.  Make sure all cups are
                               completely submerged.

                 9.6.1.3        Cover beaker with aluminum foil and let stand for at least 30 minutes.

                 9.6.1.4        Decant the cleaning solution from the beaker into a chloroform/methanol waste bottle
                               without losing any cups.  Remove any remaining solution from the beaker using a glass

                                                   IV-66

-------
                                                                                        Chapter IV
                                                                         Water Quality Monitoring
                                                                                        August 1996


                        transfer pipette.

           9.6.1.5       Using clean metal forceps, transfer cups individually to a 150 mL hydrochloric acid
                        washed glass container of acetone. Hold cup momentarily in acetone then remove and
                        drain acetone from cup. Do this twice for each cup.

           9.6.1.6       Transfer cup to 150 mL hydrochloric acid washed glass container of fresh reagent
                        water.  Be sure cups are completely submerged and resting on the bottom of the
                        container.

           9.6.1.7       Cover container with aluminum foil and let stand at least 15 minutes.

           9.6.1.8       Decant water from beaker and remove remaining water with a glass transfer pipette.

           9.6.1.9       Place clean cups on a clean sheet of aluminum foil and dry in oven at 100 - 200°C for at
                        least 2 hours. DO NOT exceed 200°C; tin cups will become brittle.

           9.6.1.10      Wrap dry cups in aluminum foil or place into a glass, hydrochloric acid cleaned
                        container and desiccate until use.

9.6.2       Standards and Standard Curve Equipment Preparation

           9.6.2.1       Tin cups must  always be handled with clean metal forceps. The forceps, metal ANA
                        sealing plate and metal spatula must be rinsed with fresh reagent water and completely
                        dried with Kimwipes.  Always work on a clean aluminum foil-covered surface
                        whenever handling standards or samples.

           9.6.2.2       Calibrate the electronic microbalance at the 200 mg range each day prior to weighing
                        any standards.

9.6.3       Standardization

           9.6.3.1       For PC analysis of glass fiber filters, Chloramine-T (N-chloro-p-toluenesulfonamide
                        sodium salt) or other suitable standards are used as the standard.  Standards should
                        weigh approximately 0.05 to 2.0 mg.

           9.6.3.2       Using metal forceps to handle tin cups, weigh a clean tin cup on calibrated
                        microbalance, and tare the balance to eliminate the weight of the cup from the weight
                        measurement.

           9.6.3.3       Apply balance brake and remove cup. Place cup  on clean ANA metal sealing plate and
                        unfold cup somewhat.

           9.6.3.4       Using a clean metal spatula, place approximately 0.05 to 2.0 mg Chloramine T into cup
                        and, using forceps (2 pairs), seal tin cup.

           9.6.3.5       Place sealed standard on microbalance, weigh, and record weight on data sheet.
                                             IV-67

-------
                                                                                             Chapter IV
                                                                               Water Quality Monitoring
                                                                                              August 1996


                 9.6.3.6       For the standard curve, 3 blanks (empty clean tin cups), then 7 Chloramine T standards
                              of known weight are analyzed on the Carlo Erba C/N analyzer in conjunction with the
                              Carlo Erba E. A.G.E.R. computer software.

                 9.6.3.7       Chloramine T standards in the standard curve are analyzed as STD sample types and
                              CHLOR-T standard types.  Blanks are analyzed as BLANK sample types.

                 9.6.3.8       If the correlation coefficient for the standard curve is below the minimum acceptable
                              value, for a maximum 2 standards and/or 1 blank may be omitted from the standard
                              curve (minimum of 2 blanks and 5 standards are required for a standard curve).  A
                              standard can be omitted by bypassing the standard in the sample table and recalculating
                              the curve.

       9.6.4      Analysis of Glass Fiber Filter Samples

                 9.6.4.1       Set flow rates as outlined in the Carlo Erba NA 1500 Nitrogen/Carbon Analyzer
                              Instruction Manual. Set control panel parameters as follows:

                                              Filament temperature               190°C
                                              Oxygen injection stop     67 seconds
                                              Peak enable                       10 seconds
                                              Cycle stop                       410 seconds
                                              (this may need to be increased if carbon peak on Chromatogram is
                                              not completed during cycle time).

                 9.6.4.2       Set autosampler tray with space #1 aligned with window on the front of the
                              autosampler.

                 9.6.4.3       Place blanks and standards in spaces 1-10 of autosampler tray and, using the Carlo Erba
                              E.A.G.E.R. computer software, generate the standard curve.

                 9.6.4.4       After an acceptable standard curve has been generated, place one wrapped sample or
                              standard in each space of the autosampler tray and, using the E.A.G.E.R. software, and
                              analyze the samples.

                 9.6.4.5       In order to  demonstrate that the instrument was still in calibration at the end of the
                              analytical run, the last sample analyzed in any series of analyses must be a standard.

                 9.6.4.6       Samples will have a known volume of sample water filtered onto them.  Divide that
                              volume (in mL) by 10, and place this value in the sample weight column of the sample
                              table of the E.A.G.E.R. file.

                 9.6.4.7       The cycle time used in the E.A.G.E.R. program parameters should be 10  seconds longer
                              than the cycle stop time set on the C/N analyzer instrument panel.

9.7    Quality Control

       9.7.1      The correlation coefficient of the calibration curve must greater than  or equal to 0.990.

                                                   IV-68

-------
                                                                                       Chapter IV
                                                                         Water Quality Monitoring
                                                                                        August 1996


9.7.2       Run a duplicate of each sample, and a Chloramine T standard after every 5 samples (sample and it's
           duplicate count as one sample).  If the samples are not all analyzed in duplicate, a minimum of one
           duplicate must be analyzed after every 10 samples, and at least 2 duplicates must be analyzed per
           analytical run.

9.7.3       The calibration check standards are analyzed as unknown sample types. Recovery must be within 90-
           110% of actual value. If recovery of a standard falls outside these limits, it is considered to be "out-of-
           control," and all samples analyzed after the last "in-control" standard must be reanalyzed.

9.7.4       Prepare and analyze at least two standards (2 "in-control" standards must occur consecutively before
           proceeding with analyses).

9.7.5       Re-prepare and reanalyze each sample which was analyzed after the last "in-control" standard.
                                            IV-69

-------
                                                                                              Chapter IV
                                                                               Water Quality Monitoring
                                                                                              August 1996


10.    Dissolved Organic Carbon

10.1   Scope and Application

      10.1.1     This method includes the measurement of dissolved organic carbon in surface and saline waters. The
                 method is most applicable to measurement of dissolved organic carbon above 1 mg/L.

10.2   Summary of Method

      10.2.1     The sample is filtered, acidified to a pH of 3, and purged with high purity air immediately prior to
                 analysis in order to remove inorganic carbon. The dissolved organic carbon is converted to carbon
                 dioxide (CO2) by catalytic combustion using a platinum catalyst at 680 ± 2°C. Carbon atoms are
                 oxidized into carbon dioxide which is measured by the nondispersive infrared detector. The amount of
                 CO2 is directly proportional to the concentration of dissolved carbonaceous material in the sample.

10.3   Interferences

      10.3.1     Carbonate and bicarbonate carbon represent an interference under the terms of this test and must be
                 removed or accounted for in the final calculation. (Frequently removed by sparging sample with high
                 purity air immediately prior to sample analysis.)

      10.3.2     This procedure is applicable only to homogeneous samples which can be injected into the apparatus
                 reproducibly by means of a microliter type syringe or pipette.  The openings of the syringe or pipette
                 limit the maximum size of particles which may be included in the sample.

10.4   Apparatus and Materials

      10.4.1     TOC analyzer equipped with a platinum catalyst and a nondispersive infrared detector.

                 10.4.1.1       A number of companies manufacture systems for measuring carbonaceous material in
                               liquid samples.  Considerations should be made as to the types of samples to be
                               analyzed, the expected concentration range, and forms of carbon to be measured.

                 10.4.1.2       No specific analyzer is recommended as superior, however, the analyzer being used
                               must have the capacity to maintain a combustion temperature of 680 ± 2°C.

      10.4.2     Glassware: Because carbon contamination is difficult to avoid, all glassware must be stringently
                 cleaned.  One method is to  wash with 10% HC1, rinse with DI water, rinse with acetone, rinse with DI
                 water, and dry  in a 100°C oven.  A second method is to wash with 10% HC1, rinse with DI water, and
                 place in muffle furnace at 450  ± 2°C for two hours.

10.5   Reagents

      10.5.1     Reagent Grade Water: see section 1.9.

      10.5.2     Potassium Hydrogen Phthalate, stock solution,  1000 mg carbon/L: Dissolve 0.2128 g of potassium
                 hydrogen phthalate (Primary Standard Grade) in distilled water and dilute  to 100.0 mL.
                                                   IV-70

-------
                                                                                               Chapter IV
                                                                                Water Quality Monitoring
                                                                                               August 1996


                 NOTE:       Sodium oxalate and acetic acid are not recommended for stock solutions.

       10.5.3     Potassium Hydrogen Phthalate, standard solutions: Prepare at least four standard solutions from the
                 stock solution by dilution with distilled water and add 4 mL of 6 N HCl/liter to each.

       10.5.4     Carbonate-bicarbonate, standard solution: Prepare a series of standards similar to step 10.5.3.  A
                 minimum of three standards and a blank must be used for calibration.

                 NOTE:  This standard is not required by some instruments.

       10.5.5     Blank Solution:  Use the same distilled water (or similar quality water) used for the preparation of the
                 standard solutions.

       10.5.6     Hydrochloric Acid (HC1), 6N.

10.6   Sample Handling

       10.6.1     Samples must be acidified to a pH of less then or equal to 3 with H2SO4 or HCland stored at 4 ± 2°C if
                 the sample will be analyzed within 28 days.  If the sample will not be analyzed within 28 days, freeze
                 the sample prior to acidification and store it at -20 ± 2°C.

       10.6.2     Sampling and storage of samples in glass bottles is preferable. Sampling and storage in plastic bottles
                 such as conventional polyethylene and cubitainers is permissible if it is established that the containers
                 do not contribute contaminating organics to the samples or alter the carbon concentration. Some
                 plastics actually  absorb carbon out of samples.

                 NOTE:       A brief study performed in an EPA Laboratory indicated that distilled water stored in
                               new, one quart cubitainers did not show any increase in organic carbon after two weeks
                               exposure.

       10.6.3     Because  of the possibility of oxidation or bacterial decomposition of some components of aqueous
                 samples, the lapse of time between collection of samples and start of analysis should be kept to a
                 minimum. Also, samples should be kept cool (4 ± 2°C) and protected from sunlight and atmospheric
                 oxygen.

10.7   Procedure

       10.7.1     The pH of the filtered samples is adjusted to less than 3 using 6N HC1.

                 NOTE: Under normal conditions, the sample should arrive at the laboratory as a filtrate.  The
       Contractor
shall ensure that all DOC samples have been filtered as required for the analysis.

       10.7.2     The compressed air is turned on and the TOC Analyzer is allowed to come to steady state at 680 ± 2°C
                 and in accordance with manufacturer's specifications.

       10.7.3     Set conditions for automated analysis per manufacturer's specifications.


                                                   IV-71

-------
                                                                                               Chapter IV
                                                                                Water Quality Monitoring
                                                                                               August 1996


       10.7.4     Check syringe position with injection port, make sure compressed air is on, and make sure SPARGE
                 switch is on if sparging is required.

       10.7.5     For calibration of the instrument, it is recommended that a series of at least four to five standards
                 encompassing the expected concentration range of the samples be used.

       10.7.6     Follow manufacturer's instructions for calibration.

       10.7.7     Analytical sequence: The following sequence is reccommended for sample analysis.

                 10.7.7.1       Four to five calibration standards with concentrations within the linear range of the test.

                 10.7.7.2       Two method blanks.

                 10.7.7.3       Ten CBP samples.

                 10.7.7.4       One matrix spike sample and one sample duplicate.

                 10.7.7.5       One medium concentration calibration standard.

                 10.7.7.6       One method blank.

                 10.7.7.7       Steps 10.7.7.3 - 10.7.7.6 are repeated until are samples are analyzed or QC samples
                               indicate that the system is out of control and recalibration is necessary.

                 10.7.7.8       One high concentration calibration standard.

                 10.7.7.9       One medium concentration calibration standard.

                 10.7.7.10     One low concentration calibration standard.

10.8   Quality Control

       10.8.1     Method detection limits (MDL):  Method detection limits should be established using the guidelines in
                 Chapter II, Section E.

       10.8.2     Calibration

                 10.8.2.1       Linear calibration range:  Calibration standards should bracket the range of CBP
                               samples.

                 10.8.2.2       Correlation coefficient: The correlation coefficient must be 0.99 or better for the
                               calibration curve to be used.

       10.8.3     Method blank:  see Chapter II, section D.

       10.8.4     Matrix spike sample: see Chapter II, section D.
                                                    IV-72

-------
                                                                                         Chapter IV
                                                                           Water Quality Monitoring
                                                                                         August 1996
      10.8.5     Reference materials:  The laboratory must analyze a standard reference material once a year, as
                available.

      10.8.6     All CBP samples must be analyzed a minimum of two times.

10.9   References

      Annual Book of ASTM Standards, Part 31, "Water", Standard D 2574-79, p 469 (1976).

      Standard Methods for the Examination of Water and Wastewater, 14th Edition, p 532, Method 505, (1975).
                                                IV-73

-------
                                                                                            Chapter IV
                                                                              Water Quality Monitoring
                                                                                             August 1996


11.    Biochemical Oxygen Demand. 5 Day

11.1   Scope and Application

      11.1.1     The 5-day Biochemical Oxygen Demand (BOD5) determination is an empirical test in which
                 standardized laboratory procedures are used to determine the relative oxygen requirements of surface
                 waters, wastewaters, effluents, and polluted waters. This test measures the amount of oxygen used
                 over a 5-day incubation period for the biochemical degradation of organic material (carbonaceous
                 demand) and the oxygen used to oxidize inorganic material such as sulfides and ferrous iron. It also
                 may measure the oxygen used to oxidize reduced forms of nitrogen (nitrogenous demand) unless their
                 oxidation is prevented by an inhibitor.

11.2   Summary of Method

      11.2.1     Upon arrival in the laboratory, each BOD5 sample is brought to approximately 20°C. Sample dilutions
                 are made so as to approximate a final DO of at least 1 mg/L and a DO uptake of at least 2 mg/L.
                 Diluted samples are neutralized and treated with a nitrification inhibitor, if required, and an initial
                 dissolved oxygen (DO) reading is taken and recorded for each sample. The BOD bottles are sealed
                 with DI water, capped, and incubated at 20 ± 1°C for a period of 5 days. After the 5-day incubation
                 period, a final DO reading is made and the BOD5 is calculated from the difference between the initial
                 and final DO.

11.3   Interferences

      11.3.1     Nitrogenous oxygen demand as a result of the oxidation of reduced forms of nitrogen by
                 microorganisms is the most common interference in determining BOD5 values.

                 11.3.1.1      The extent of nitrogenous demand during the 5-day incubation period depends on the
                              presence of microorganisms capable of carrying out the oxidation.

                 11.3.1.2      Nitrogenous  oxygen demand can be prevented by the use of an inhibitory chemical. If
                              an inhibitory chemical is not used, the oxygen demand measured is the sum of
                              carbonaceous (CBOD5) and nitrogenous (NBOD5) demands.

      11.3.2     Because the BOD5 test is a bioassay, its results can be influenced greatly by the presence of toxicants
                 such as residual chlorine and heavy metals. Care should be taken in the cleaning of glassware and
                 sample containers, and in the preparation of reagents.

      11.3.3     Photosynthetic production of DO may also influence BOD5 results. Care should be taken to store and
                 incubate BOD5 samples in the dark.
                                                  IV-74

-------
                                                                                               Chapter IV
                                                                                Water Quality Monitoring
                                                                                               August 1996
11.4   Apparatus and Materials
       11.4.1     Incubation bottles, 250- or 300-mL glass-stoppered BOD bottles with plastic caps. Clean bottles,
                 stoppers, and caps with a laboratory detergent, rinse thoroughly, and drain before use.

       11.4.2     Air incubator, thermostatically controlled at 20 ± 1°C.

       11.4.3     DO meter and probe, calibrated.

11.5    Reagents

       NOTE:  Discard reagents that show any sign of biological growth.

       11.5.1     Phosphate Buffer Solution: pH 7.

       11.5.2     Nitrification Inhibitor:  2-chloro-6-(trichloro methyl) pyridine.

       11.5.3     Glucose-Glutamic Acid Solution:  Dry reagent grade glucose and reagent grade glutamic acid at 103 ±
                 2°C for 1 hour.  Add 150 mg glucose and 150 mg glutamic acid to distilled water and dilute to 1 L.
                 Prepare fresh before each use.

       11.5.4     Magnesium Sulfate Solution:  Dissolve 22.5 g MgSO4«7H2O in distilled water and dilute to 1 L.

       11.5.5     Calcium Chloride Solution: Dissolve 27.5 g CaCl2 in distilled water and dilute to 1 L.

       11.5.6     Ferric chloride solution: Dissolve 0.25 g FeQ3«6H2O in distilled water and dilute to 1 L.

       11.5.7     Acid and alkali solutions, IN, for neutralizing caustic or acidic samples:

                 11.5.7.1      Acid:  Slowly and while stirring, add 28 mL concentrated sulfuric acid (H2SO4) to
                              distilled water. Dilute to 1 L.

                 11.5.7.2      Alkali: Dissolve 40 g sodium hydroxide (NaOH) in distilled water. Dilute to 1 L.

       11.5.8     Dilution water:  Place the desired amount of ASTM type  II water (see section 1.9) in a suitable
                 container. For every liter of water add 1 mL each of phosphate buffer, MgSO4, CaCl2, and FeCl3
                 solutions. Before use bring to 20 ± 2°C and saturate with DO by shaking in a partially filled bottle or
                 by aerating with organic-free filtered air.

11.6    Sample Handling

       11.6.1     Sample holding time:  The recommended holding time is 6 hours or less.  The maximum allowable
                 holding time is 48 hours from sample collection.

       11.6.2     Sample preservation and storage: Samples for BOD5 analysis may degrade significantly  during
                 storage and analysis, resulting in low BOD5 values.

                 11.6.2.1      If analysis is not started within 2 hours of collection, keep samples in the dark and at 4

                                                   IV-75

-------
                                                                                              Chapter IV
                                                                                Water Quality Monitoring
                                                                                               August 1996


                               ±2°C.

                 11.6.2.2       If analysis is started within 2 hours of collection, cold storage is unnecessary.

11.7  Procedure

      11.7.1     Sample preparation

                 11.7.1.1       Allow the samples to stabilize to 20 ± 2°C.

                 11.7.1.2       Neutralize samples to pH 6.5 to 7.5 with either the IN H2SO4 solution or the INNaOH
                               solution.

                 11.7.1.3       Using the dilution water from 12.5.8, make several dilutions of each sample to obtain a
                               final DO of at least 1 mg/L and a DO uptake of at least 2 mg/L. Dilutions may be made
                               directly in the BOD bottles by adding the desired volume of sample and filling the
                               BOD bottle to about 2/3 with dilution water. Experience with the samples from
                               specific monitoring stations may permit use of a smaller number of dilutions. In
                               general, dilutions of 25 to 100 percent may be needed.

                 11.7.1.4       For each sample dilution, pour approximately 200 mL of the diluted sample into a
                               cleaned BOD bottle and add 3 mg 2-chloro-6-(trichloro methyl) pyridine.

                 11.7.1.5       Fill the BOD bottle to the top with either dilution water or diluted sample, depending
                               on whether the dilution was made  in the BOD bottle or in a graduated cylinder.

      11.7.2     Initial DO measurement

                 11.7.2.1       Using a calibrated DO meter and probe, measure and record the DO for each field and
                               QC sample.

                 11.7.2.2       Reduce the DO in samples containing more than 9 mg DO/L at 20 ± 2°C by vigorous
                               shaking or by aeration with clean,  filtered  compressed air. Measure and record the DO
                               for the sample.

                 11.7.2.3       Rinse the DO electrode between determinations to prevent cross-contamination of
                               samples.

      11.7.3     Incubation

                 11.7.3.1       Replace any displaced contents and gently insert the glass stopper so that it displaces all
                               air, leaving no bubbles.

                 11.7.3.2       Cap and water-seal the stoppered bottle and incubate for 5 days at 20 ± 1°C.

      11.7.4     Final DO measurement

                 11.7.4.1       Using a calibrated DO meter and probe, measure and record the DO for each field and

                                                   IV-76

-------
                                                                                             Chapter IV
                                                                               Water Quality Monitoring
                                                                                              August 1996


                              QC sample.

11. 8 Quality Control

       11.8.1      Glucose-glutamic acid check

                 11.8.1.1      Check dilution water quality and analytical technique at a frequency of no less than
                              once every six months.

                 11.8.1.2      Determine BOD5 at 20 ± l°Cfora2 percent dilution of the glucose-glutamic acid
                              standard check solution using the same techniques used to determine BOD5 for the CBP
                              samples.

       1 1.8.2      Method detection limits (MDL):  Method detection limits should be established using the guidelines in
                 Chapter II, Section D.

       11.8.3      Calibration

                 11.8.3.1      Linear calibration range : Calibration standards should bracket the range of CBP
                              samples.

                 11.8.3.2      Correlation coefficient: The correlation coefficient must be 0.99 or better for the
                              calibration curve to be used.

       1 1.8.4      Method blank: The laboratory must analyze method blanks of both substitute ocean water and reagent
                 water at a minimum of every 10 CBP samples. Method blank data are used to assess contamination
                 from the laboratory environment.  If the concentration of analyte in the reagents blank exceeds the
                 MDL, then laboratory or reagent contamination should be suspected. If the analyte concentration is 5
                 times the MDL or greater, then corrective action is required and reanalysis if possible.

       1 1.8.5      Matrix spike sample:  The laboratory  should add a known amount of analyte to a minimum of 10%  of
                 the routine samples or one sample per sample set,  whichever is greater. The analyte concentration
                 should be high enough to be seen above the original concentration of the sample and should not be less
                 than four times the calculated minimum detectable concentration.

                 11.8.5.1      Calculate  the percent recovery of analyte from the matrix spike sample using the
                              following equation:
                                                 _  OD
             Matrix Spike Recovery =  -^ - — x  100                                               (Eq. IV.21)

-------
                                                                                             Chapter IV
                                                                               Water Quality Monitoring
                                                                                              August 1996
                 where,

                              SSR = Spike sample result
                              SR  = Sample result
                              SA  = Spike added

                 11.8.5.2      If the recovery of the analyte falls outside the designated range, repeat the spike after
                              checking for obvious sources of error. If the recovery of the replicated spike of the
                              same sample again falls outside the designated range, the recovery problem
                              encountered with the spiked sample is judged to be matrix related, not system related
                              and no further corrective action is required.

       11.8.6     Laboratory duplicate: A laboratory duplicate must be analyzed once for every 10 CBP samples.

                 11.8.6.1      The precision is measured by calculating the coefficient of variation (CV) using the
                              following equation:
           CV =           x  100, where SD  = .
                   MEAN                         \
(N-  1)
                 where,
                              CV  =  Coefficient of variation
                              SD  =  Standard deviation
                              Mean = Mean of the replicate readings
                              N  = Number of samples

                 11.8.6.2      If the CVdoes not fall within the control limits listed in Table II. 1, corrective action
                              should be taken.

       11.8.7     Reference materials: The laboratory must analyze a standard reference material once a year, as
                 available.
11.9  References
      American Public Health Association.  1989.  Standard Methods for the Examination of Water and Wastewater,
                 17th Edition.
                                                       (Eq. IV.22)
                                                   IV-78

-------
                                                                                             Chapter IV
                                                                              Water Quality Monitoring
                                                                                             August 1996


12.    Chlorophyll and Phaeophytin

12.1   Scope and Application

      12.1.1     This spectrophotometric method is used in the determination of chlorophyll a, b, and c, phaeophytin-a,
                 and carotenoids. This method can be used to estimate phytoplankton biomass.

12.2   Summary of Method

      12.2.1     The reference for this method is ASTM Method D3731-79. In brief, algal cells are ground in aqueous
                 acetone to extract the pigments. The extract is analyzed using a spectrophotometer to measure the
                 absorbances at the correct wavelengths.

12.3   Apparatus and Materials

      12.3.1     Laboratory coat: worn at all times and with an apron when handling acids.

      12.3.2     Protective eyewear:  worn at all times.

      12.3.3     PVC gloves: worn at all times.

      12.3.4     Glass fiber filter: Whatman GF/F or equivalent.

      12.3.5     Centrifuge.

      12.3.6     Dual beam spectrophotometer:  or scanning spectrophotometer with matched cuvettes.

      12.3.7     Tissue  Grinder.

      12.3.8     Filtration Apparatus

12.4   Reagents

      12.4.1     Solvents:

                 12.4.1.1      Hydrochloric acid (IN), Hcl.

                 12.4.1.2      Sodium bicarbonate solution (IN), (NaH(CO3)2), dissolve 8.4 g sodium bicarbonate  in
                              100 mL water.

                 12.4.1.3      Magnesium carbonate suspension, (MgCO3), add 1 g finely powdered magnesium
                              carbonate to 100 Ml water.

                 12 A.I A      Aqueous acetone (90%), add 1 part water to 9 parts of reagent grade acetone, add 5
                              drops of NaH(CO3)2 solution to every volume, made within 24-48 hours of time of use.

      12.4.2     Reagent Grade Water: See section 1.9.
                                                  IV-79

-------
                                                                                              Chapter IV
                                                                                Water Quality Monitoring
                                                                                               August 1996
                 12 A.2.1       Reference standards: use EPA SRM reference standards if provided.

12.5    Sample Handling

       12.5.1     After the addition of magnesium carbonate, samples can be held for 24 hours at 0-4°C.  The extract
                 can be store at -20 ± 2°C for a maximum 30 days.

12.6    Filtration Procedure

       12.6.1     Using a 47 mm GF/F, Pour a measured amount of well mixed sample (typically 500ml) through filter.
                 Apply vacuum to complete filtration process.

       12.6.2     Add approximately 1 ml of Magnesium Carbonate Suspension and apply vacuum to dryness.

       12.6.3     Release vacuum and remove filter.  Store as required. Record sample volume filtered.

12.7    Grinding Procedure

       12.7.1     Place filter in grinding vessel and add 2-3 ml of 90% acetone.

       12.7.2     Insert pestle into grinding vessel and turn on grinder.

       12.7.3     Grind filter for approximately  2 minutes being sure there are no discernible pieces remaining.

       12.7.4     Pull pestle from vessel and rinse with 90% acetone.

       12.7.5     Transfer sample to centrifuge tube using a glass funnel and 90% acetone for rinsing.

       12.7.6     Record filtration volume.

12.8    Procedure

       12.8.1     Adjust the temperature of the centrifuge so that unit cools to 4 ± 2°C. Centrifuge samples for 30
                 minutes at 4500 rpm. Keep centrifuged samples level, cool, and in a dark box.

       12.8.2     Zero the dual beam spectrophotometer at 750 nm using the 90% acetone reagent. After zeroing the
                 spectrophotometer, leave the cuvette in the reference cell.

                 Using a matched pair of cuvettes, one cuvette is used to zero the spectrophotometer at each
                 wavelength; and the other cuvette contains the sample, so that the chlorophyll sample is not transferred
                 back to the chlorophyll tube after the initial turbidity absorbance is obtained at the 750 nm wavelength.
                 To account for any differences between the two cuvettes, the cuvette which will contain the samples is
                 first filled with 90% acetone and the absorbance is read on the spectrophotometer.  If this absorbance
                 is not zero, the value obtained is used to adjust all of the chlorophyll readings. The acetone in the
                 reference and zeroing cuvettes must be  rehomogenized periodically throughout the analysis.

                 Record sample volume filtered and extract volume in screw-cap test tube onto the data sheet. Note

                                                   IV-80

-------
                                                                                               Chapter IV
                                                                                Water Quality Monitoring
                                                                                               August 1996


                 that the volume of the filter residue in the bottom of the centrifuge tube must be subtracted from the
                 total volume to obtain extract volume.  Then carefully dispense the sample into the sample cuvette
                 using a disposable glass pipette, and measure absorbances at the following wavelengths:  750 nm, 664
                 nm, 647 nm, 630 nm, 480 nm, and 510 nm.

       12.8.5     Re-zero spectrophotometer with 90% acetone before reading at each wavelength.  After the 510 nm
                 reading is taken, add 2 drops of IN HCL.  After 1 minute, but not longer than 2 minutes after
                 acidification, measure sample absorbances at 750 nm and 665 nm. Zero with the blank at each
                 absorbance before reading.

12.9   Quality Control

       12.9.1     The initial absorbance reading at 750 nm must be less than or equal to .007, or sample(s) must be re-
                 centrifuged. If after re-centrifugation the absorbance reading at 750nm is greater than .007, continue
                 to measure the absorbances at the rest of the wavelengths and write in the comment section that the
                 sample had been recentrifuged.

       12.9.2     It is especially important to maintain the spectrophotometers in peak operating condition.  This should
                 be confirmed by the following guidelines:

                 12.9.2.1       Analyzing an EPA SRM reference standard for chlorophyll analysis if provided.

                 12.9.2.2       Periodic evaluation of the slopes of calibration curves from spectrophotometer analyses
                               for other parameters for which there are reliable standards (e.g. orthophosphate, nitrite,
                               etc.). If significant slope deviation or consistent unidirectional slope change over time
                               is noted, an alternate spectrophotometer should be used until the problem is corrected
                               by  an authorized repair person.

                 12.9.2.3       The holmium oxide absorption spectrum should be analyzed at least annually or when
                               problems are suspected.  Details are not provided here since this and subsequent
                               evaluation should be performed only by or under direct supervision of experienced
                               personnel.

       12.9.3     Method detection limits (MDL): Method detection limits should be established using the guidelines in
                 Chapter II, Section D.

       12.9.4     Method blank:  see Chapter II, Section C.

       12.9.5     Laboratory duplicate:  see Chapter II, Section C.

       12.9.6     Reference materials:  The laboratory must analyze a standard reference material once a year, as
                 available.

12.10  References

       American Public Health Association.  Standard Methods for the Examination of Water and Wastewater.
       17th Edition.
                                                   IV-81

-------
                                                                               Chapter IV
                                                                  Water Quality Monitoring
                                                                               August 1996
Parsons, T., Y. Malta and C . Lalli.  1984. A Manual of Chemical and Biological Methods for Seawater
Analysis.  Pergamon Press, pp.  101-112.
                                        IV-82

-------
                                                                                                Chapter IV
                                                                                 Water Quality Monitoring
                                                                                                August 1996


13.     Total Suspended Solids

13.1    Scope and Application

       13.1.1      This method is applicable to drinking, surface, and saline waters, domestic and industrial wastes.  The
                  practical range of the determination is 2 to 20,000 mg/L.

13.2    Summary of Method

       13.2.1      A well-mixed sample is filtered through a glass-fiber filter, and the residue retained on the filter is
                  dried to constant weight at 103 - 105°C.

13.3    Interferences

       13.3.1      Filtration apparatus, filter material, pre-washing, post-washing, and drying temperature are specified
                  because these variables have been shown to affect the results.

       13.3.2      Samples high in filterable residue (dissolved solids), such as saline waters, brines and some wastes,
                  may be subject to a positive  interference.  Care must be taken in selecting the filtering apparatus so
                  that washing of the filter and any dissolved solids in the filter minimizes this potential interference.

13.4    Apparatus and Materials

       13.4.1      Glass fiber filter discs:  Whatman 47 mm diameter,.70 • ftipore size, or equivalent.

       13.4.2      Filter support: Filtering apparatus with reservoir and a coarse (40-60 microns) fritted disc as a filter
                  support.

                  NOTE:  Many funnel designs are available in glass or porcelain.  Some of the most common are
                  Hirsch or Btichner funnels, membrane filter holders and Gooch crucibles. All are available with
                  coarse fitted disc.

       13.4.3      Suction flask.

       13.4.4      Drying oven:  Capable of maintaining a temperature of 103-105°C.

       13.4.5      Desiccator.

       13.4.6      Analytical balance: Capable of weighing to 0.1 mg.

13.5    Sample Handling

       13.5.1      Non-representative particulates such as leaves, sticks, fish,  and lumps of fecal matter should be
                  excluded from the sample if it is determined that their inclusion is not desired in the final result.

       13.5.2      Preservation of the sample is not practical; analysis should begin as soon as possible. Refrigeration 4
                  ± 2°C, or freezing -20 ± 2°C to minimize microbiological decomposition of solids, is recommended.
                                                    IV-83

-------
                                                                                               Chapter IV
                                                                                Water Quality Monitoring
                                                                                               August 1996


13.6  Procedure

       13.6.1     Preparation of filters:

                 13.6.1.1       Number glass fiber filters with a fine-point indelible ink pen.  Allow ink to dry for 24
                               hours.

                 13.6.1.2       Place the numbered glass fiber filter on the membrane filter apparatus.

                 13.6.1.3       While vacuum is applied, wash the filter with three successive 30 ml volumes of
                               deionized, distilled water. Allow the vacuum pump to run until the filters are "dry".

                 13.6.1.4       Remove the filter from membrane filter apparatus and dry in an oven at 103 - 105°C for
                               four hours.

                 13.6.1.5       Cool in a desiccator, weigh each filter, record the filter number and weight in a
                               notebook set aside for this purpose, and return the filter to the drying tray.

                 13.6.1.6       Return the tray to the oven, 103 - 105°C , for one hour. Repeat the drying cycle until a
                               constant weight is obtained (weight verification 0.5 mg or less is obtained).

                 13.6.1.7       Record the second filter weight in the notebook and store the filters in aluminum cups
                               in an oven at 60 ± 5°C, or in a desiccator until needed.

       13.6.2     Sample analysis:

                 13.6.2.1       List filter numbers and sample indefications on Suspended Solids sheet.

                 13.6.2.2       Assemble the filtering apparatus, place a pre-weighed numbered filter on it, and begin
                               suction.

                 13.6.2.3       Shake the sample vigorously and with a small portion of sample. Quantitatively
                               measure  500 mL of sample into the graduated cylinder. Record the volume of sample
                               used beside the corresponding filter and sample on the Suspended Solids sheet.

                               NOTE: A smaller volume may be used if sample contains a large amount of suspended
                               matter.

                 13.6.2.4       Pour the measured sample volume onto the filter.  Remove all traces of water by
                               continuing to apply vacuum after sample has passed through.

                 13.6.2.5       With suction on, wash the filter, non-filterable residue and filter funnel wall with three
                               portions of deionized, distilled water allowing complete drainage between washing.
                               Remove all traces of water by continuing to apply vacuum after water has passed
                               through.

                 13.6.2.6       Carefully remove the filter from the filter support. Alternatively, remove crucible and
                               filter from crucible adapter. Dry at least one hour at 103-105°C. Cool in a desiccator

                                                   IV-84

-------
                                                                                             Chapter IV
                                                                               Water Quality Monitoring
                                                                                              August 1996
                              and weigh. Repeat the drying cycle until a constant weight is obtained (weight loss of
                              0.5 mg or less is obtained). Record both weights on the data sheet and determine the
                              concentration of the Suspended Solids in mg/L.
13.7   Quality Control
       13.7.1     Method detection limits (MDL):  Method detection limits should be established using the guidelines in
                 Chapter II, Section E.

       13.7.2     Method blank: see Chapter II, Section D.

       13.7.3     Laboratory duplicate: see Chapter II, Section D.

       13.7.4     Reference materials: The laboratory must analyze a standard reference material once a year, as
                 available.

13.8    References

       U.S. EPA, 1979, "Methods for Chemical Analysis of Water and Wastes". Method 160.2.
                                                   IV-85

-------
                                                                                               Chapter IV
                                                                                 Water Quality Monitoring
                                                                                                August 1996


14.     Fixed Suspended Solids

14.1    Scope and Application

       14.1.1     This method is used to obtain the amount of fixed suspended solids present in the solid fraction of
                 sewage, activated sludge, industrial wastes, or bottom sediments.


14.2    Summary of Method

       14.2.1     The residue obtained from the determination of total suspended solids is ignited at 550 ± 2°C in a
                 muffle furnace. The remaining solids after ignition is reported as mg fixed suspended solids/L.

14.3    Interferences

       14.3.1     The principal source of error in the determination is failure to obtain a representative sample.

       14.3.2     The test is subject to many errors due to loss of water of crystallization, loss of volatile organic matter
                 prior to combustion, incomplete oxidation of certain complex organics, and decomposition of mineral
                 salts during combustion.

14.4    Apparatus and Materials

       14.4.1     Filtration flask.

       14.4.2     Drying oven:  Capable of maintaining a temperature of 103-105 ± 2°C.


       14.4.3     Muffle furnace.

       14.4.4     Desiccator.

       14.4.5     Analytical balance: Capable of weighing to 0.1 mg.

14.5    Sample Handling

       14.5.1     Preservation of the sample is not practical; analysis should begin as soon as possible. Refrigeration 4
                 ± 2°C, or freezing  -20 ± 2°C to minimize microbiological decomposition of solids is recommended.

14.6    Procedure

       14.6.1     Ignite the residue from the suspended solids procedure at 550 ± 50°C for approximately  15 to 20
                 minutes in a muffle furnace to a constant weight.

       14.6.2     Let the dish or filter disk partially cool in air until most of the heat has dissipated. Transfer to a
                 desiccator and cool to room temperature. Repeat the drying cycle until a constant weight is obtained
                 (weight verification of 0.5 mg or less is obtained).  Record the weight on the data sheet and determine
                 the concentration of the fixed suspended solids by using the following equation in mg/L by subtracting

                                                    IV-86

-------
                                                                                           Chapter IV
                                                                             Water Quality Monitoring
                                                                                           August 1996


                 the weight of the residue plus the dish after ignition from the weight of the dish times 1000 over the
                 volume of sample used.


                                        (WRD ~  WD) x 100°
            Concentration (mg/L)  = ——	                                             (Eq. IV.25)
                 where,
                             WRD  = Weight of residue and dish
                              WD = Weight of dish
                              V = Volume of sample filtered
14.7   Quality Control
      14.7.1      Method detection limits (MDL): Method detection limits should be established using the guidelines in
                 Chapter II, Section E.

      14.7.2      Method blank: see Chapter II, Section C.

      14.7.3      Laboratory duplicate: see Chapter II, Section C.

      14.7.4      Reference materials: The laboratory must analyze a standard reference material once a year, as
                 available.

14.8   References

      U.S. EPA, 1979, Methods for Chemical Analysis of Water and Wastes. Method 160.2.

      Annual Book of ASTM Standards, "Fixed and Volatile Solids Ignited at 550°C", Standard D 2540, Method E, p 2-
                 77 (1980).
                                                 IV-87

-------
                                                                                              Chapter IV
                                                                               Water Quality Monitoring
                                                                                              August 1996


15.     Silicates

15.1    Scope and Application

       15.1.1     This method is applicable to drinking, surface, and saline waters, domestic and industrial wastes.

       15.1.2     The working range of the method is approximately 0.01 to 1.4 mg/L of SiO2.

15.2    Summary of Method

       15.2.1     A well-mixed sample is filtered through a 0.45 • •Whatman GF/F.  The filtrate, a silicamolybdate in
                 acidic solution, is reduced to "molybdenum blue" by ascorbic acid. Oxalic acid is introduced to the
                 sample stream before the addition of ascorbic acid to eliminate interference from phosphates.

15.3    Interferences

       15.3.1     Excessive color and/or turbidity interfere. Correct by running blanks prepared without addition of the
                 ammonium molybdate solution.

       15.3.2     Large amounts of iron and sulfide interfere.

       15.3.3     Contact with glass should be minimized, silica free reagents should be used as much as possible. A
                 blank should be run.

15.4    Apparatus and Materials

       15.4.1     Continuous flow  automated analytical system equipped with an autosampler, manifold, proportional
                 pump, colorimeter, phototube and recorder or computer based data system.

       15.4.2     Appropriate glassware: Whenever possible, all reagents and standards should be made and stored in
                 plastic containers.  Contact with glass should be minimized.
15.5   Reagents

      15.5.1     Reagent Grade Water: See section 1.9.

      15.5.2     Ammonium Molybdate:  To a one-liter volumetric flask, add approximately 500 mL of 0.1 N sulfuric
                 acid (H2SO4). Dissolve 10 g of ammonium molybdate ((NH4)6Mo7O24'4H2O). Dilute to one liter with
                 0.1 N H2SO4. Store in an amber plastic container. This solution is stable for approximately one month
                 at 4°C.

      15.5.3     Oxalic Acid:  Add approximately  900 mL of reagent water to a one liter volumetric flask. Dissolve 50
                 g of oxalic acid (H2C2O4) (or 70 g of (COOH)2«?H2O) and dilute to one liter with reagent water stable
                 indefinitely at 4°C.

      15.5.4     Ascorbic Acid: To a one liter volumetric flask, add 500 mL of reagent water. Dissolve 17.6 g of

                                                   IV-88

-------
                                                                                               Chapter IV
                                                                                Water Quality Monitoring
                                                                                                August 1996


                 ascorbic acid (C6H8O6), add 50 mL of acetone (CH3COCH3), mix, and dilute to one liter with reagent
                 water stable at one month at 4°C.

       15.5.5     Silica Stock Solution: In a one liter volumetric flask, add 500 mL of reagent water.  Dissolve 1.88 g of
                 sodium fluorosilicate (Na2SiF6) and dilute to volume with reagent water.  Store in tightly stoppered
                 plastic bottle at room temperature.

       15.5.6     Silica Standard Solutions: Prepare at least four standard solutions from stock solution by dilution with
                 reagent water. Prepare standard solutions on the day of analysis.

15.6   Sample Handling

       15.6.1     Samples are filtered through a Whatman GF/F glass fiber filter or equivalent filter and stored at
                 unacidified for 28 days 4°C .

15.7   Procedure

       15.7.1     Allow both the colorimeter and recorder to warm up for 30 minutes.  Obtain a stable baseline with all
                 reagents, feeding reagent water through the sample line.

       15.7.2     Analytical sequence: The following sequence is recommended for sample analysis..

                 15.7.2.1      Five calibration standards with concentrations within the linear range of the test.

                 15.7.2.2      Two method blanks.

                 15.7.2.3      Ten CBP samples.

                 15.7.2.4      One matrix spike sample and one sample duplicate.

                 15.7.2.5      One medium concentration calibration standard.

                 15.7.2.6      One method blank.

                 15.7.2.7      Steps  15.7.3.5 - 15.7.3.8 are repeated until are samples are analyzed or QC samples
                               indicate that the system is out of control and recalibration  is necessary.

                 15.7.2.8      One high concentration calibration standard.

                 15.7.2.9      One medium concentration calibration standard.

                 15.7.2.10      One low concentration calibration standard.

       15.7.3     Switch sample line from distilled water to sampler and begin analysis.

       15.7.4     Prepare appropriate standard curve by plotting peak heights of processed standards against known
                 concentrations. Compute concentration of the samples by comparing sample peak heights with
                 standard curve.

                                                   IV-89

-------
                                                                                              Chapter IV
                                                                                Water Quality Monitoring
                                                                                               August 1996


                 NOTE: Subtract the blank background response from the standards before preparing the standard
                 curve.

       15.7.5     Record the stabilized potential of each unknown sample and convert the potential reading to the silica
                 concentration using the standard curve.

15.8   Quality Control

       15.8.1     Method detection limits (MDL): Method detection limits should be established using the guidelines in
                 Chapter II, Section E.

       15.8.2     Calibration

                 15.8.2.1       Linear calibration range:  Calibration standards should bracket the range of CBP
                               samples.

                 15.8.2.2       Correlation coefficient: The correlation coefficient must be 0.99 or better for the
                               calibration curve to be used.

       15.8.3     Method blank: see Chapter II, Section D.

       15.8.4     Matrix spike sample: see Chapter II, Section D.

       15.8.5     Laboratory duplicate:  see Chapter II, Section D.

       15.8.6     Reference materials: The laboratory must analyze a standard reference material once a year, as
                 available.

15.9   References

       Standard Methods for the Examination of Water and Wastewater, 14th Edition, p 487, Method 426 F (1975).

       Annual Book of ASTM Standards, Part 31, "Water", Standard D 859-68, p 401 (1976).

       Standard Methods for Chemical Analyses of Water and Wastes, EPA-600/4-79-020, Edition 1978, p 370.1-1,
                 Method 370.1  (1978).
                                                   IV-90

-------
                                        Chapter IV
                                Water Quality Monitoring
                                          August 1996
MANIFOLD CONFIGURATION FOR  SILICA
Wash Water
to Sampler






V\






faste




proportioning rum
G G
Bk Bk
O O
Bk Bk
Bk Bk
0 0
Red Red

P
2.0 Wash
0.32 Air
Sampler
40/hr
4:1
0.42 Molybdate
0.32 Sample
0.32 Oxalic Acid
0.42 Ascorbic Acid
0.80 Waste


    Colorimeter
    50 mm Flow Cell
    650-660 nm filter
Recorder
                         IV-91

-------
                                                                                                 Chapter IV
                                                                                  Water Quality Monitoring
                                                                                                  August 1996


16.     Alkalinity

16.1   Scope and Application

       16.1.1      The alkalinity of a water is its acid-neutralizing capacity, and it comprises the sum of all titrable bases.
                  Alkalinity is a measure of an aggregate property of water and can be interpreted in terms of specific
                  substances only when the chemical composition of the sample is known.  While alkalinity values may
                  include contributions from borates, phosphates, silicates, and other bases, the alkalinity of most
                  surface waters is primarily a function of carbonate, bicarbonate, and hydroxide content.

16.2   Summary of Method

       16.2.1      Alkalinity is dependent upon the pH of the solution and is a measure of its quantitative capacity to
                  neutralize a strong acid to a designated pH (hydroxyl ions are neutralized). In this instance, the initial
                  pH is taken and the solution is carefully titrated with a standardized H2SO4 solution to a pH of 8.3 (if
                  necessary) and then to a pH of 4.5. Carbonate and total alkalinity values are calculated directly from
                  the titration data, and any existing bicarbonate alkalinity is calculated as the difference between total
                  and carbonate alkalinities.

16.3   Interferences

       16.3.1      Soaps, oily matter, suspended solids, or precipitates may coat the glass electrode and cause a sluggish
                  response.  Allow additional time between titrant additions to let electrode come to equilibrium and
                  clean electrode more frequently. Do not filter,  dilute, concentrate, or alter the sample.

       16.3.2      Dissolved gases contributing to  alkalinity, such as CO2, hydrogen sulfide,  or ammonia, may be lost or
                  gained during sampling, storage, or titration.

16.4   Apparatus and Materials

       16.4.1      pH meter and electrode, calibrated according to manufacturer's specifications at pH 4, 7, and 10.

       16.4.2      Buret, bororsilicate glass, of appropriate volume to contain enough titrant for at least one complete
                  titration.

       16.4.3      Titration vessels, the size and form will depend on the electrode and the sample size.

       16.4.4      Parafilm.

       16.4.5      Magnetic stirrer.

       16.4.6      Pipets, volumetric.

       16.4.7      Flasks, volumetric, 1-L.

       16.4.8      Analytical balance, capable of weighing to 0.001 g and calibrated according to manufacturer's
                  specifications using Class S weights.
                                                     IV-92

-------
                                                                                              Chapter IV
                                                                                Water Quality Monitoring
                                                                                               August 1996


16.5   Reagents

      16.5.1     Certified pH buffer solutions for pH 4, 7, and 10.

      16.5.2     Sodium Carbonate Solution, approximately 0.05N: Dry 3 to 5 g primary standard Na2CO3 at 250 ± 2°C
                 for 4 hours and cool in desiccator.  Weigh 2.5 + 0.2 g (to the nearest mg), transfer to a 1-L volumetric
                 flask, fill with approximately 500 mL of distilled water, swirl until the Na2CO3 is dissolved, and then
                 fill the flask to the 1-L mark with distilled water. Do not keep for longer than 1 week.

      16.5.3     Standard Sulfuric Acid Solution, 0.02N: Prepare acid solution of approximate normality.  Standardize
                 daily by potentiometric titration of Na2CO3  standard solution.

16.6   Sample Handling

      16.6.1     Sample holding time: The recommended maximum holding time is 24 hours from sample collection.

      16.6.2     Sample preservation and storage:

                 16.6.2.1       If analysis is not started within 2 hours of collection, keep samples at or below 4 ± 2°C.

                 16.6.2.2       If analysis is started within 2 hours of collection, cold storage is unnecessary.

      16.6.3     To minimize loss or absorption of gases, avoid sample agitation and prolonged exposure to air.

16.7   Procedure

      16.7.1     Calibrate the pH meter and electrode using certified buffer solutions at pH 4,  7, and 10.  A fresh
                 aliquot of each buffer should be used daily.

      16.7.2     Rinse electrode with distilled water.

      16.7.3     Rinse and fill burette with H2SO4 solution.

      16.7.4     Standardize the H2SO4 solution by  titrating  10.00 mL of the 0.05N Na2CO3 standard solution.  Please
                 note that the actual normality of the Na2CO3 solution must be calculated based on the exact weight of
                 dried standard used.

      16.7.5     Adjust sample to room temperature (if necessary), pour sample aliquot (100ml) into a clean titration
                 vessel, introduce a Teflon coated stirring bar into the sample and place on a magnetic stirrer.

      16.7.6     Position burette so that the acid goes directly into the titration vessel. The buret tip must be above
                 sample level at all times.

      16.7.7     Cover the titration vessel with parafilm, making small apertures for the pH electrode and the tip of the
                 buret.

      16.7.8     Measure and record the initial pH.
                                                   IV-93

-------
                                                                                               Chapter IV
                                                                                Water Quality Monitoring
                                                                                                August 1996


       16.7.9     Record initial buret reading.

       16.7.10    If the initial pH is less than 8.3, then proceed to Section 17.7.12, otherwise continue as described in
                 Section 17.7.11.

       16.7.11    Slowly add standard sulfuric acid solution until a pH of 8.3 is reached.  Record pH and the titration
                 volume.

       16.7.12    Add standard sulfuric acid solution until a pH of approximately 6 is reached.  Slowly add more acid,
                 until a pH of 4.5 is reached, record pH and the final titration volume.

       16.7.13    Calculate and report carbonate and total alkalinities. If the initial pH was 8.3 or greater, also calculate
                 and report bicarbonate alkalinity.

16.8   Quality Control

       16.8.1     Method detection limits (MDL): Method detection limits should be established using the guidelines in
                 Chapter II, Section D.

       16.8.2     Laboratory duplicate:  see Chapter II, Section C.

       16.8.3     Reference materials:  The laboratory must analyze a standard reference material once a year, as
                 available.

16.9   References

       American Public Health Association. 1989. Standard Methods for the Examination of Water and Wastewater,
                 17th Edition.

       McGraw-Hill, Chemistry and Environmental Engineering, pp. 364-376.

       Strickland and Parsons, A Practical Handbook of Seawater Analysis, pp.  27-28.
                                                    IV-94

-------