LT2ESWTR  Data Collection  and
              Tracking  System  Factsheet
WHAT Is THE LT2ESWTR?
The U.S. Environmental Protection Agency (EPA) published the Long Term 2 Enhanced Surface Water Treatment
Rule (LT2ESWTR) on January 5, 2006. The LT2ESWTR requires EPA, states, public water systems (PWSs), and
laboratories to work together collecting source water monitoring data soon  after the rule is finalized.

WHAT ARE THE IPMC AND DCTS?	

EPA developed the Information Processing and Management Center (IPMC) and Data Collection & Tracking
System (DCTS) to help manage data submissions and notifications associated with rule implementation. The
IPMC is a processing center that manages electronic and hard copy submittals, the  DCTS, and sends notification
letters. The DCTS ensures that PWSs can review and approve laboratory-reported data before EPA or the state
may access the data. The laboratories can enter data using data collection forms or upload data in XML format.
The LT2 Data  Collection System automatically calculates final analytical results to  reduce the potential for
human error.

The IPMC and  DCTS have been designed to help EPA and states save time and money by serving as a central
processing center that enables real-time tracking, enhances collaboration between states and EPA, and
streamlines recordkeeping. Technical assistance is available for IPMC and DCTS users. The DCTS will enable EPA
and state reviewers to share notifications, PWS and  state contacts, PWS profiles, and data generated for the
LT2ESWTR.

WHO SHOULD USE THE DCTS?	

The DCTS allows states, PWSs, laboratories, and EPA to upload, review, and/or download information.
Specifically, the DCTS allows laboratories to upload  Cryptosporidium  and E. coli sampling results. In addition,
PWSs can use  the DCTS to upload  sampling schedules and turbidity sampling results and to review and approve
or contest their sampling results uploaded by the laboratory. EPA and states will use the DCTS to track PWSs'
progress through compliance with the LT2SWTR source water monitoring requirements. For example EPA and
states  will review sampling schedules and sampling results. The following schematic summarizes the
information flow between labs, PWSs, EPA,  and states within the DCTS.


Upl
XA
i
La
Analyz
Sam
A
P
f
bmps

bs
e PWS
pies
Sample

Resample
notification
k
Provides list
rovides
results
rom QC
: hecks
Dad PWS data via
1L files or enter
/ia web forms
or samples
to review
LT2D



PWSs
Review
lab input
i


Grandfathered data
• i
1
1 1 Provides data to
• be considered for
EPA a
States
Review Lab
and PWS input
1 Grandfathering ^J
Review
and
Provides list ofi
"" . " Grandfathered
samples | data to review -
r ^v
ata Collection
System
*


— >

t
Provides list of
samples to
review

SDWIS
Accepts and
stores
acceptable
data

-------
How DOES THE DCTS WORK?
The DCTS is a Web-based application that allows for both manual entry and batch uploads. The system is
password protected and accessible only by approved EPA, state drinking water staff, PWSs, and laboratories.
Submissions to the DCTS are not considered confidential business information (CBI) and are subject to the
Freedom of Information Act (FOIA).

PWSs can create their sampling schedules in the DCTS by entering individual dates, generating a recurrence
pattern, or copying a previously entered schedule from another facility. Throughout monitoring, the DCTS
compares monitoring dates to scheduled dates to verify compliance. A PWS can also submit data through the
DCTS that they want EPA or the state to consider allowing them to use as grandfathered data.

After PWSs collect Cryptosporidium, E. coli, and turbidity samples and submit them to a laboratory for
analysis, the laboratory posts the analytical results  to the DCTS. When the laboratory approves and releases the
sampling results for PWS review, the PWS can logon to the DCTS to review the data. The PWS must
electronically approve the data within 10 days of the end of month following the month the sample was
collected. [Note: If the PWS does not approve their posted data in that time period, the database will
automatically process the data  as submitted by the laboratory with a flag to indicate the PWS did not approve
the data.] When Cryptosporidium monitoring is complete, the PWS uses the sampling data to calculate the
mean Cryptosporidium concentration. DCTS can keep  a running calculation of the mean Cryptosporidium
concentration for  the PWS, but a final calculation and bin determination will need to be submitted by the PWS
to EPA or the state.

All PWSs serving at least 10,000 people must report results from the initial source water monitoring to EPA
electronically at www.epa.gov/safewater/disinfection/tools/tools-dcts.html. A PWS that is unable to report
monitoring results electronically may use an EPA or state approved alternative approach for reporting. PWSs
serving less than 10,000 people must report results  from the initial source water monitoring to the state. EPA
encourages all systems to submit their source water monitoring results electronically.  The following table
summarizes options available to labs and systems for submitting data to the DCTS.

                  Options for  Meeting LT2ESWTR Submission Requirements to the  DCTS 1
              Option 1
 Upload sampling schedule or sampling
 data directly to the Web site 2
                 Option 2
      With EPA or state approval, mail
      paper copies to:
           US EPA-1 PMC
           P.O. Box 98
           Dayton, OH 45401
                         Option 3 2
             With EPA or state approval,
             e-mail electronic submissions as
             attachments to:
             stage2mdbp@epa. gov
1 PWSs and labs must use one of these three options to submit information to the DCTS. In addition, PWSs can send copies of submissions
to the state, but this is not required.
2 Go to EPA's Web site at www.epa.gov/safewater/disinfection/tools/tools-dcts.html to submit information (e.g., sampling schedule,
monitoring data, or intent to provide maximum treatment) and for a list of acceptable file formats.

WILL  THE DCTS INTEGRATE INTO OTHER DATABASE SYSTEMS?	

Although the database design is independent of EPA's Safe Drinking Water Information System (SDWIS), the
DCTS is built to easily integrate with EPA's Office of Water's data systems (i.e., Central Data Exchange (CDX),
and SDWIS). For example, a state can download an XML file (e.g., inventory, laboratory, or violation schema)
from the DCTS and then have the option to upload the file to SDWIS/State or other state databases.

How  CAN THE DCTS BE ACCESSED?	

The DCTS is available on the Web, but requires a username and password. The site is located at
www.epa.gov/safewater/disinfection/tools/tools-dcts.html. Each laboratory and PWS that is registered with
the DCTS has an Administrative User. The Administrative User is responsible for the initial registration of the
entire lab or PWS.
For additional information, please contact the Safe Drinking Water Hotline at 1-800-426-4791,
send an email to stage2mdbp@epa.gov. or visit www.epa.gov/safewater/disinfection/lt2.
Office of Water (4606)
EPA816-F-06-019
www.epa.gov/safewater/disinfection/lt2
June 2006

-------