PARTNER
                               ENERGY STARŪ Program Requirements
                                          for Commercial  Fryers

                                          Partner Commitments
Commitment
       The following are the terms of the ENERGY STAR Partnership Agreement as it pertains to the
manufacturing of ENERGY STAR qualified commercial fryers. The ENERGY STAR Partner must adhere
to the following program requirements:

       comply with current ENERGY STAR Eligibility Criteria, defining the performance criteria that must
       be met for use of the ENERGY STAR certification mark on commercial fryers and specifying the
       testing criteria for commercial fryers. EPA may, at its discretion, conduct tests on products that
       are referred to as ENERGY STAR qualified. These products may be obtained on the open
       market, or voluntarily supplied by Partner at EPA's request;

       comply with current ENERGY STAR Identity Guidelines, describing how the ENERGY STAR
       labels and name may be used.  Partner is responsible for adhering to these guidelines and for
       ensuring that its authorized representatives, such as advertising  agencies, dealers, and
       distributors, are also in compliance;

       qualify at least one ENERGY STAR qualified commercial fryer model within one year of activating
       the commercial fryers portion of the agreement. When Partner qualifies the product, it must meet
       the specification (e.g., Tier 1 or 2, if applicable) in effect at that time;

       provide clear and consistent labeling of ENERGY STAR qualified commercial fryers. The
       ENERGY STAR label must be clearly displayed on the front/inside of the product, in product
       literature (i.e., user manuals, spec sheets, etc.), and on the manufacturer's Internet site where
       information about ENERGY STAR qualified models is displayed;

       provide to EPA, on an annual basis, an updated list of ENERGY STAR qualifying commercial fryer
       models.  Once the Partner submits its first list of ENERGY STAR qualified commercial fryer
       models, the Partner will be listed as an ENERGY STAR Partner. Partner must provide annual
       updates in order to remain on the list of participating product manufacturers;

       provide to EPA, on an annual basis, unit shipment data or other market indicators to assist in
       determining the market penetration of ENERGY STAR. Specifically, Partner must submit the total
       number of ENERGY STAR qualified commercial fryers shipped (in units by model) or an
       equivalent measurement as agreed to in advance by EPA and Partner.  Partner is also
       encouraged to provide ENERGY STAR qualified unit shipment data segmented by meaningful
       product characteristics (e.g., capacity, size, speed, or other as relevant), total unit shipments for
       each model in its product line, and percent of total unit shipments that qualify as ENERGY STAR.
       The data for each calendar year should be submitted to EPA, preferably in electronic format, no
       later than the following March and  may be provided directly from the Partner or through a third
       party. The data will be used by EPA only for program evaluation purposes and will be closely
       controlled. If requested under the  Freedom of Information Act (FOIA), EPA will argue that the
       data is exempt. Any information used will be masked by EPA so as to protect the confidentiality of
       the Partner;

       notify EPA of a change in the designated responsible party or contacts for commercial fryers
       within 30 days.
ENERGY STAR Program Requirements for Commercial Fryers

-------
Performance for Special Distinction
       In order to receive additional recognition and/or support from EPA for its efforts within the
Partnership, the ENERGY STAR Partner may consider the following voluntary measures and should keep
EPA informed on the progress of these efforts:

       consider energy efficiency improvements in company facilities and pursue the ENERGY STAR
       label for buildings;

       purchase ENERGY STAR qualified products.  Revise the company purchasing or procurement
       specifications to include ENERGY STAR.  Provide procurement officials' contact information to
       EPA for periodic updates and coordination. Circulate general ENERGY STAR qualified product
       information to employees for use when purchasing products for their homes;

       ensure  the power management feature is enabled on all ENERGY STAR qualified monitors in use
       in company facilities,  particularly upon installation and after service is performed;

       provide general information about the ENERGY STAR program to employees whose jobs are
       relevant to the development, marketing, sales, and service of current ENERGY STAR qualified
       product models;

       feature  the ENERGY STAR label(s) on Partner Web site and in other promotional materials. If
       information concerning ENERGY STAR is provided on the Partner Web site as specified by the
       ENERGY STAR Web Linking Policy (this document can be found in the Partner Resources
       section  on the ENERGY STAR Web site at www.enerqystar.qov), EPA may provide links where
       appropriate to the Partner Web site;

       provide a simple plan to EPA outlining specific measures Partner plans to undertake beyond the
       program requirements listed above. By doing so, EPA may be able to coordinate,  communicate,
       and/or promote Partner's activities, provide an EPA representative, or include news about the
       event in the ENERGY STAR newsletter, on the ENERGY STAR Web pages, etc. The plan may
       be as simple as providing a list of planned activities or planned milestones that Partner would like
       EPA to  be aware of.  For example, activities may include: (1) increase the availability of ENERGY
       STAR qualified products by converting the entire product line within two years to meet ENERGY
       STAR guidelines; (2)  demonstrate the economic and environmental benefits of energy efficiency
       through special in-store displays twice a year; (3) provide information to users (via the Web site
       and user's manual) about energy-saving features and operating characteristics of ENERGY STAR
       qualified products; and (4) build awareness of the ENERGY STAR Partnership and brand identity
       by collaborating with EPA on one print advertorial and one live press event;

       provide quarterly, written updates to EPA as to the efforts undertaken by Partner to increase
       availability of ENERGY STAR qualified products, and to promote awareness of ENERGY STAR
       and its  message.
ENERGY STAR Program Requirements for Commercial Fryers

-------
  ENERGYSTAR
ENERGY STARŪ Program Requirements
           for Commercial  Fryers

                Eligibility Criteria
Below is the product specification (Version 1.0) for ENERGY STAR qualified commercial fryers. A product
must meet all of the identified criteria if it is to be labeled as ENERGY STAR by its manufacturer.

1)  Definitions: Below is a brief description of a commercial fryer and other terms as relevant to ENERGY
    STAR.

    A.  Commercial Open, Deep-Fat Fryer:  An appliance, including a cooking vessel, in which oil is
       placed to such a depth that the cooking food is essentially supported by displacement of the
       cooking fluid rather than  by the bottom of the vessel. Heat is delivered to the cooking fluid by
       means of an immersed electric element or band-wrapped vessel (electric fryers), or by heat
       transfer from gas burners through either the walls of the fryer or through tubes passing through
       the cooking fluid (gas fryers).

    B.  Cooking Energy Efficiency: The quantity of energy input to the food product (e.g., French fries)
       during the cooking process; expressed as a percentage of the quantity of energy input to the fryer
       during the heavy-, medium-, and light-load tests.  For purposes of this specification, heavy-load
       will be used as a measurement of energy efficiency.

    C.  Heavy (French fry) Load Cooking: A 3-pound load of frozen shoestring potatoes, divided evenly
       into 11/2-lb loads and placed in two baskets  for cooking.

    D.  Idle Energy Rate: The rate of fryer energy consumption while it is maintaining or holding the frying
       medium at the thermostat(s) set point. For purposes of this specification, idle energy rate is
       measured by Btu/h (gas) or watts (electric).


2)  Qualifying Products: Any commercial fryer that  meets the definition in Section 1A is eligible for the
    ENERGY STAR.
3)  Energy-Efficiency Specifications for Qualifying Products: Only those products listed in Section 2 that
    meet the following criteria may qualify as ENERGY STAR:
Energy Efficiency Requirements for Open Deep-Fat Gas Fryers
Heavy Load (French fry) Cooking
Energy Efficiency
Idle Energy Rate
> 50%
< 9,000 Btu/h r*
         *Based on 15-inch fryer
Energy Efficiency Requirements for Open Deep-Fat Electric Fryers
Heavy Load (French fry) Cooking
Energy Efficiency
Idle Energy Rate
> 80%
< 1000 watts*
         *Based on 15-inch fryer
ENERGY STAR Program Requirements for Commercial Fryers

-------
4)  Test Criteria: Manufacturers are required to perform tests and self-certify those product models that
    meet the ENERGY STAR guidelines. The test results must be reported to EPA using the Commercial
    Fryer Qualifying Product Information Form.

    In performing these tests, partner agrees to measure a model's cooking energy-efficiency and idle rate
    using ASTM Standard F1361 -99, Test Method for the Performance of Open Deep Fat Fryers.


5)  Effective Date: The date that manufacturers may begin to qualify products as ENERGY STAR will be
    defined as the effective  date of the agreement. The ENERGY STAR Specification for Commercial
    Fryers is effective August 15, 2003.
6)  Future Specification Revisions: ENERGY STAR reserves the right to change the specification should
    technological and/or market changes affect its usefulness to consumers, industry, or the environment.
    In keeping with current policy, revisions to the specification are arrived at through industry
    discussions. Please note that ENERGY STAR qualification is not automatically granted for the
    life of the product model. To carry the ENERGY STAR label, a product model must meet the
    ENERGY STAR specification in effect on the model's date of manufacture.
ENERGY STAR Program Requirements for Commercial Fryers

-------