                  Environmental Technology Verification Program
                                   Verification Statement

TECHNOLOGY TYPE: Passive Soil Gas Sampler

APPLICATION:       Subsurface Soil Sampling

Technology Name:     EXFLUX® Soil Gas Investigation System

Company:            Quadrel Services, Inf.
Address:              1896 Urbana Pike, Suite 20
                     Clarksburg, MD 20871

Phone:               (800) 878-5510

ETV Program Description

The U.S. Environmental Protection Agency (EPA created the Environmental Technology Verification (ETV)
Program to facilitate the deployment of innovative technologies through performance verification and information
dissemination. The goal of the ETV Program is to further environmental protection by substantially accelerating the
acceptance and use of improved and cost-effective technologies. The ETV Program is intended to assist and inform
those involved in the design distribution, permitting, and purchase of environmental technologies. This document
summarizes the results of a demonstration of the EMFLUX® Soil Gas Investigation System.

Program Operation

Under the ETV Program and with the full participation of the technology developer, the EPA evaluates the
performance of innovative technologies by developing demonstration plans, conducting field tests, collecting and
analyzing demonstration data, and preparing reports. The technologies are evaluated under rigorous quality assurance
(QA) protocols to ensure that data of known and adequate quality are generated and that the demonstration results are
defensible. The EPA's National Exposure  Research Laboratory,  which demonstrates field characterization and
monitoring technologies, selected Tetra Tech EM Inc. as the verification organization to assist in field testing various
soil and soil gas sampling technologies. This demonstration was  conducted under the EPA's Superfund Innovative
Technology Evaluation Program.

Demonstration Description

In May and June 1997, The EPA conducted a field test of the EMFLUX® system along with three other soil and two
gas sampling technologies. This Verification statement focuses on the EMFLUX® system ; similar statements have
been prepared for each of the other technologies. The performance of the EMFLUX® system was compared to a
reference subsurface soil sampling method (hollow-stem auger drilling and split-spoon sampling) in terms of the
following parameters: (1) sample recovery, (2) volatile organic compound (VOC)  concentrations in recovered
samples, (3) sample integrity, (4) reliability and throughput, and (5) cost. Data quality indicators for precision,
accuracy, representativeness, completeness, and comparability were also assessed against project-specific QA
objectives to ensure the usefulness of the data.

-------
The EMFLUX® system was demonstrated at two Sites: The Small Business Administration (SBA) site in Albert City,
Iowa, and the Chemical Sales Company (CSC) site in Denver, Colorado. These sites were chosen because of the wide
range of VOC concentrations detected at the sites and because each has a distinct soil type. The VOCs detected at the
sites include cis-l,2-dichloroethene (cis-l,2-DCE); 1,1,1-trichloroethane (1,1,1-TCA); trichloroethene (TCE); and
tetrachloroethene (PCE). Soils at the SBA site are composed primarily of clay, and soils at the CSC site are
composed primarily of medium- to fine-grained sand. A complete description of the demonstration, including a data
summary and discussion of results, is available in a report titled Environmental Technology Verification Report: Soil
Sampler,SimulProbe®'Technologies,Inc., QuadrelServices, Inc. (Quadrel), EMFLUX, EPA/600/R-98/096).


TECHNOLOGY DESCRIPTION

The EMFLUX<" system is a passive soil gas sampling technology designed for use in shallow deployment to identify
and quantify a broad range of VOCs and semivolatile organic compounds (SVOC), including halogenated
compounds,
petroleum hydrocarbons, polynuclear aromatic hydrocarbons, and other compounds present at depths to more than
200 feet. For this ETV demonstration, the EMFLUX<" system consisted of the EMFLUX« sample cartridge, sample
insertion tools, and developer-provided sample analysis. The EMFLUX ® cartridge consists of 100 milligrams of
sorbent sealed in a fine-mesh screen, which is placed in a glass vial; the vial and cartridge make up the EMFLUX"
field collector. This  assembly is inserted into the soil, but only the cartridge is thermally desorbed and analyzed in
the laboratory. The EMFLUX« field collector is installed by creating a three to four-inch deep pilot hole using a
manual hammer and a stake, and inserting the sampler manually.  The sampler is then covered to reduce the potential
for sorption of airborne contaminants. The cartridge is retrieved by hand and, for this demonstration, was analyzed
by the developer. The EMFLUX« system also includes computer modeling by Quadrel using a proprietary model
to predict periods of maximum soil gas emission for geographic locations and optimize sampling efficiency.
However, the performance of the model was not evaluated during the demonstration.

VERIFICATION OF PERFORMANCE

The demonstration data indicate the following performance characteristics for the EMFLUX" system:

VOC Detection and Quantitation: Soil gas samples collected using the EMFLUX" system and the reference soil gas
sampling method at  nine grids at both the sites were analyzed for six target VOCs. Analysis of EMFLUX" samples
yielded results in total nanograms per sample, which Quadrel converted to mass per unit volume of air (nanograms
per liter [ng/L]). The reference method also produced results in mass per unit volume of air (ng/L). A comparison
of the mean VOC concentrations calculated for each sampling method at each grid indicates that the EMFLUX *
system identified the presence of all of the VOC compounds detected by the reference soil gas sampling method in 24
of 25 cases. In addition, in 7 of 31 cases, the EMFLUX" system also reported VOCs that the reference method did
not detect but were identified as present during previous soil and groundwater investigations at the demonstration
sites. This performance characteristic suggests that the EMFLUX" system can detect the presence of lower
concentrations of VOCs in soil  gas than the reference soil gas sampling method. In addition, the sample locations
where the EMFLUX" system reported high VOC concentrations  generally corresponded to the sample locations
where the reference method also reported high VOC concentrations. However, the values  in the two data sets do not
appear to exhibit any direct or consistent proportional relationship, and the mean concentrations of VOCs calculated
using the reference method data were typically one to four orders of magnitude higher than those  calculated using the
EMFLUX" system for samples from the same grid. Because the EMFLUX * system relies on diffusion of soil gas
from subsurface sources such as contaminated soil or groundwater, the performance range for the EMFLUX" system
may be controlled by factors such as depth to the contaminant source, contaminant concentrations and diffusion rates,
soil type and organic content, the detection limits of the methods  used to analyze the samples,  and possibly other
factors. However, during the demonstration, the system was evaluated at locations with relatively shallow subsurface
contamination, and was only evaluated with regard to its ability to detect certain targeted VOCs. For these reasons,
the performance range of the EMFLUX« system was not fully established by the demonstration data. It should be
noted that the EMFLUX« system and reference method are field  screening techniques that provide only an estimate
of the actual concentration of contaminants in soil gas. Because the EMFLUX« system and reference method use

-------
different techniques to collect soil gas samples, it is not expected that the two methods will provide the same
response and that the data will be directly comparable. Because the mean VOC concentrations for the data sets differ
by several orders of magnitude in most instances, a statistical analysis of the data was not performed and
interpretation of the chemical concentration data for this demonstration is limited to qualitative observations.

Sample Retrieval Time: Installation of the EMFLUX " system averaged 3.0 minutes per sample at the  SBA site and
4.0 minutes per sample at the CSC site. For the demonstration, the samplers were left in place for approximately 4
days at each site. Collection of the samplers required an average of 2.3 minutes per sample at the SBA site and 3.2
minutes at the CSC site. Overall, installation and collection of 35 samples at the SBA site required 187 minutes, an
average of 5.3 minutes per sample, and installation and collection of 28 samples at the CSC site required 201
minutes, an average of 7.2 minutes per sample. The analysis and reporting by the technology developer required an
additional 12 days for the SBA site data and 16 days for the CSC site data from the time samples were collected until
the laboratory report was delivered. The reference soil gas method required 458 minutes to collect 35 samples at the
SBA site, an average of 13.1 minutes per sample, and 183 minutes to collect 28 samples at the CSC site, an average
of 6.5 minutes per sample. One day was required per site to analyze the samples and report the results. Based on the
demonstration results, the average sample retrieval times for the EMFLUX" system were quicker than those of the
reference soil gas sampling method in the clay soils at the SBA site  and slower than those of the reference sampling
method in the sandy soils at the CSC site. During sample collection using the reference soil gas sampler, the clay soil
at the SBA site  caused the system to hold its vacuum at several  sampling locations; therefore, soil gas was not
completely drawn into the system for sampling. In these cases, the rod was withdrawn in additional 6-inch increments
until the vacuum was broken and the system's pressure reached equilibrium with atmospheric pressure. The vacuum
problem was not encountered in the sandy soil at the CSC site. At both sites, one person collected soil gas samples
with the EMFLUX« system, and a three-person sampling crew  collected and analyzed soil samples using  the
reference sampling method.

Cost. Based on  the demonstration results, the EMFLUX« system costs $85 to $195 per sample plus equipment costs
of $25 to $90 per day and mobilization/demobilization costs of $200 to $600 per day. Operating costs for  the
EMFLUX <• system ranged from $660 to $1,390 at the clay soil  site and $710 and $1,440 at the sandy soil site. For
this demonstration, the  active soil gas sampling method was procured at a lump sum of $4,700 for each site. The
oversight costs  for the active soil gas sampling method ranged from $680 to $1,260 at the clay soil site and $480 to
$910 at the sandy soil site. A site-specific cost and performance analysis is recommended when selecting  a
subsurface soil  gas sampling method.

A qualitative performance assessment of the EMFLUX" system indicated that (1) the samplers are reliable in that
100 percent of the required samples were collected without sample losses; (2) the samplers are easy to use and
require minimal training (a 16-minute training video is available from the developer); (3) logistical requirements for
the EMFLUX®  system differ from those of the reference sampling method because the EMFLUX« field collectors
are installed using a hammer-driven, 6-inch steel rod, left in place for several days,  retrieved by hand, and sent to the
developer for analysis;  and (4) sample handling in the field was easier than the reference method because the only
requirements are that the recovered cartridges be properly packed and shipped to the developer for analysis.

The demonstration results indicate that the EMFLUX" system can provide useful, cost-effective data for
environmental
problem-solving. The EMFLUX« system successfully collected soil gas samples in clay and sandy soils. The sampler

provided positive identification of target VOCs and may be able to detect lower concentrations of VOCs in the soil
gas than the reference method. The results of the demonstration did not indicate consistent proportional
comparability between the EMFLUX" data and the reference method's data. As with any technology selected, the
user must determine what is appropriate for the application and the project data quality objectives.

Gary J.  Foley, Ph.D.
Director
National Exposure Research Laboratory
Office of Research and Development

-------
NOTICE: EPA verifications are based on an evaluation of technology performance under specific, predetermined criteria and
appropriate quality assurance procedures. EPA makes no expressed or implied warranties as to the performance of the
technology and does not certify that a technology will always operate as verified. The end user is solely responsible for
complying with any and all applicable federal, state, and local requirements.

-------