EPA-452/F-03-016
                              Air Pollution Control Technology
                                                  Fact Sheet
Name of Technology: Spray-Chamber/Spray-Tower Wet Scrubber

This type of technology is a part of the group of air pollution controls collectively referred to as "wet scrubbers."
When used to control inorganic gases, they may also be referred to as "acid gas scrubbers."  When used to
specifically control sulfur dioxide (SO2), the term flue-gas desulfurization (FGD) may also be  used.

Type of Technology: Removal of air pollutants by inertial or diffusional impaction, reaction  with a sorbent
or reagent slurry, or absorption into liquid solvent.

Applicable Pollutants:

Primarily particulate matter (PM), including PM less than or equal to  10 micrometers (|j,m) in aerodynamic
diameter (PM10), PM less than or equal to 2.5 • m in  aerodynamic  diameter (PM25), and  hazardous air
pollutants (HAP) in particulate form (PMHAP); and  inorganic fumes, vapors, and gases (e.g., chromic acid,
hydrogen sulfide, ammonia, chlorides, fluorides, and SO2).  These type of scrubbers may also be used to
control volatile organic compounds (VOC).  Hydrophilic VOC maybe  absorbed by aqueous fluid, while the
addition of amphiphilic block copolymers to the water can be used to absorb hydrophobic VOC. When using
absorption as the primary control technique, the spent solvent must be easily regenerated or disposed of in
an environmentally acceptable manner (EPA, 1991).

Achievable Emission Limits/Reductions:

PM: Spray tower scrubbers generally are not used for fine PM applications because high liquid to gas ratios
(greater than 3 liters per cubic meter (l/m3) or 22.4 gallons per thousand cubic feet (gal/1000 ft3)) are required.
Collection efficiencies range from 70 to greater than 99  percent, depending upon the application. Cyclonic
spray towers generally achieve collection efficiencies at the higher end of the range (Perry, 1984; Corbitt,
1990; EPA, 1998; EPA, 1973).

Inorganic Gases: Control device vendors estimate that removal efficiencies range from 95 to 99 percent. SO2
removal efficiencies vary from 80 to greater than 99 percent, depending upon the type of reagent used and
the spray tower design. Most current applications have a removal efficiency greater than 90  percent (EPA,
1993; Sondreal,  1993; Soud, et al., 1993).

VOC:  Removal  efficiencies for gas absorbers vary for each pollutant-solvent system and with the type of
absorber used. Most absorbers have removal efficiencies in excess of 90 percent, and spray tower absorbers
may achieve efficiencies greater than 99 percent for some pollutant-solvent systems. The typical collection
efficiency range  is from 50 to 95 percent.  Lower control efficiencies represent flows containing relatively
insoluble compounds at low concentrations, while the higher efficiencies are for flows which contain readily
soluble compounds at high concentrations (EPA, 1996;  Perry, 1984; EPA, 1991).

Applicable Source Type: Point
EPA-CICA Fact Sheet                           1                           Spray-Tower Scrubber

-------
Typical Industrial Applications:

Spray tower applications include light-oil and benzene storage tank emission control using wash oil as a
solvent. Spray towers do not suffer from restrictions to gas flow by accumulated residues commonly found
in packed bed scrubbers. However, spray towers have the least effective mass transfer capability and thus,
are generally limited to use for PM removal and with high-solubility gases (EPA, 1992).

Wet scrubbers are often used as part of FGD systems, where they are used to control emissions from coal
and oil combustion from electric utilities and industrial sources. Spray towers are one of the more popularwet
scrubber configurations used to bring waste gases into contact with a sorbent designed to absorb and react
with the SO2.  Wet scrubbers have been applied  to  SO2 emissions from the primary nonferrous metals
processing (e.g., copper, lead, and aluminum), but sulfuric acid or elemental sulfur plants are more popular
control devices due to the high SO2 concentrations associated with these processes (Soud, et al., 1993).

Emission Stream Characteristics:

       a.      Air Flow:  Typical gas flow rates for spray tower wet scrubbers are 0.7 to 47 standard cubic
               meters per second (sm3/sec) (1,500  to  100,000 standard cubic feet per minute  (scfm))
               (Cooper, 1994).

       b.      Temperature:  In general, the higherthe gas temperature, the lowerthe absorption rate, and
               vice-versa.  Excessively high  gas temperatures also can lead to significant solvent or
               scrubbing liquid loss through evaporation.  For waste gases in which the PM is to  be
               controlled,  the temperature  range is generally 4 to 370-C  (40 to 700-F), and for gas
               absorption  applications, 4 to 38-C (40  to 100-F) (EPA, 1996; Avallone, 1996).

       c.      Pollutant Loading:  Typical gaseous pollutant concentrations range from 250 to  10,000
               ppmv (EPA, 1996). Spray tower wet scrubbers are not as prone to fouling as other wet
               scrubber designs, but very high liquid-to-gas ratios may be necessary to  capture fine PM
               (EPA, 1982; Perry, 1984).

       d.      Other Considerations:   For organic vapor  HAP  control  applications,   low  outlet
               concentrations will typically be required, leading to impractically tall absorption towers, long
               contact times, and high liquid-gas ratios that may not be cost-effective.  Wet scrubbers will
               generally be effective for HAP control when they are used in combination with other control
               devices such as incinerators or carbon adsorbers (EPA, 1991).

Emission Stream Pretreatment Requirements:

Precoolers  (e.g., an  additional spray chamber) may be needed to reduce  the inlet air temperature to
acceptable levels to avoid solvent evaporation or reduced absorption rates (EPA, 1996).

Cost Information:

The following are cost ranges (expressed in  2002 dollars) for spray tower wet scrubbers of conventional
design under typical operating conditions, adapted from EPA cost-estimating spreadsheets (EPA, 1996) and
referenced to the volumetric flow rate of the waste stream treated. For purposes of calculating the example
cost effectiveness, the pollutant is PM at a loading of approximately 7 grams perstandard cubic meter (g/sm3)
(3 grains per standard cubic foot (gr/scf)). The  costs do not include costs for post-treatment or disposal of
used solvent or waste.

Costs can be higher than in the ranges shown for applications which require expensive materials, solvents,
or treatment methods. As  a rule, smaller units controlling a low concentration waste stream will be more

EPA-CICA Fact Sheet                           2                           Spray-Tower Scrubber

-------
expensive (per unit volumetric flow rate) than a large unit cleaning a high pollutant load flow. Operating costs
are much more significant than capital costs for spray towers since they are relatively simple to construct and
install, and require relatively large quantities of liquid and higher water recirculation rates (EPA, 1996).

       a.      Capital Cost: $4,200 to $13,000 per sm3/sec ($2 to $6 per scfm)

       b.      O & M Cost:  $3,200 to  $64,000 per sm3/sec ($1.50 to $30 per scfm), annually

       c.      Annualized Cost: $5,300 to $102,000 per sm3/sec ($2.5 to $48 per scfm),  annually

       d.      Cost Effectiveness: $50 to $950 per metric ton ($45 to $860 per short ton), annualized
               cost per ton per year of pollutant controlled

Theory of Operation:

Spray scrubbers consist of empty cylindrical or rectangular chambers in which the gas stream is contacted
with liquid droplets generated  by spray nozzles. A common form is a spray tower,  in which the gas flows
upward through a bank or successive banks of spray nozzles.  Similar arrangements are sometimes used in
spray chambers with horizontal gas flow.  Such devices have very low gas pressure drops, and all but a small
part of the contacting power is derived from the liquid stream. The required contacting power is obtained from
an appropriate combination of liquid pressure and flow rate (Perry, 1984).

Physical absorption depends on properties of the gas stream and liquid solvent, such as density and viscosity,
as well as specific characteristics of the  pollutant(s) in the gas and the liquid stream (e.g.,  diffusivity,
equilibrium solubility). These properties are temperature dependent, and lowertemperatures  generally favor
absorption of gases by the solvent.  Absorption is also enhanced by greater contacting surface, higher liquid-
gas ratios, and higher concentrations in the gas  stream (EPA, 1991).  Chemical absorption  may be  limited
by the rate of reaction, although the rate-limiting step is typically the physical absorption rate, not the chemical
reaction rate (EPA, 1996).

Inorganic Gases Control:

Water is the most common solvent used to remove  inorganic contaminants.  Pollutant removal may be
enhanced by manipulating the chemistry of the  absorbing solution so that it  reacts with the pollutant.  An
example of this is using caustic solution for acid-gas  absorption instead of pure water as a solvent (EPA,
1996). Amphiphilic block copolymers dissolved in the water can be used to remove hydrophobic VOC, which
has much less affinity for water than hydrophilic VOC do.

Used  in FGD systems, spray tower scrubbers introduce a  reagent slurry as atomized droplets through the
spray nozzles at the top of, or in stages within the scrubber. The SO2-laden gas enters at the bottom of the
column and travels upward through the tower in a countercurrent flow, though horizontal spray towers which
use a crosscurrent design also exist. In  most cases the sorbent is an alkaline slurry, commonly limestone,
slaked lime,  or a mixture of slaked lime  and  alkaline fly ash,  though many other sorbent processes exist.
Absorption of SO2 is accomplished by the  contact between the gas reagent slurry. The sulfur oxides react with
the sorbent, forming a wet mixture of calcium sulfite and sulfate (EPA, 1981; Soud, et al., 1993).

For horizontal FGD designs, the fresh slurry (recycle and makeup streams) is often introduced at the  last, or
rear, stage of the absorber where the SO2 content  of the gas stream is lowest. The slurry contacted in the
last stage is  pumped forward to the next stage.  This way,  the slurry "flows" countercurrent to the gas flow.
The first stage of the absorber has the highest SO2 concentration gas stream and a slurry that has had much
of its active alkalinity exhausted.(EPA, 1981).
EPA-CICA Fact Sheet                           3                           Spray-Tower Scrubber

-------
PM Control:

In spray tower scrubbers, the PM-laden stream is introduced into the chamber where in comes in contact with
the liquid droplets generated by the spray nozzles. The size of the droplets generated by the spray nozzles
is controlled to maximize liquid-particle contact and, consequently, scrubber collection efficiency (EPA, 1998).

A cyclonic spray chamber is similar to a spray tower, with the exception that the is introduced in such  a way
as to produce cyclonic motion inside the chamber. The motion contributes to higher gas velocities, more
effective particle and droplet separation, and higher collection efficiency. Tangential inlet orturning vanes are
common  means of inducing cyclonic motion (EPA, 1998).

VOC Control:

Absorption is applied in chemical processing as  a raw material  and/or a product recovery technique in
separation and purification of gaseous streams containing high concentrations of organics (e.g., in natural gas
purification and coke by-product recovery operations).  In absorption, the organics in the gas stream are
dissolved in a liquid solvent. The contact between the absorbing liquid and the vent gas is accomplished in
counter current spray towers, scrubbers, or packed or plate columns (EPA, 1995).

Spray towers do not suffer from restrictions to gas flow by accumulated residues commonly found in packed
scrubbers.  However, spray towers have the least effective mass transfer capability and thus, are generally
limited to use for PM removal and with high-solubility gases (EPA, 1992).

Advantages:

Advantages of spray towers include (AWMA, 1992; EPA, 1996):

       1.      Relatively low pressure drop;

       2.      Can handle flammable and explosive dusts with little risk;

       3.      Fiberglass-reinforced plastic (FRP) construction permits operation in highly corrosive
               atmospheres;

       4.      Relatively low capital cost;

       5.      Relatively free from plugging;

       6.      Relatively small space  requirements; and

       7.      Ability to collect PM as well as gases.


Disadvantages:

Disadvantages of spray towers include  (AWMA,  1992; EPA, 1996):

       8.      May create water (or liquid) disposal problem;
       9.      Waste product collected wet;
       10.     Relatively low mass-transfer efficiencies;
       11.     Relatively inefficient at removing fine PM;
       12.     When FRP construction is used, it is sensitive  to temperature; and
       13.     Relatively high operating costs.
EPA-CICA Fact Sheet                           4                           Spray-Tower Scrubber

-------
Other Considerations:

For gas absorption, the water or other solvent must be treated to remove the captured pollutant from the
solution. The effluent from the column may be recycled into the system and used again.  This is usually the
case if the solvent is costly (e.g., hydrocarbon oils, caustic solutions).  Initially, the recycle stream may go to
a waste treatment system to remove the pollutants or the reaction product. Make-up solvent may then be
added before the liquid stream reenters the column (EPA, 1996).

For PM applications, wet scrubbers generate waste in the form of a slurry. This creates the need for both
wastewatertreatment and solid waste disposal. Initially, the slurry is treated to separate the solid waste from
the water.  The treated water can then be reused or discharged. Once the water is removed, the remaining
waste will  be in the form of a solid or sludge. If the  solid waste is inert and nontoxic, it can generally be
landfilled.  Hazardous wastes will have more stringent procedures for disposal. In  some cases, the solid
waste may have value and can be sold or recycled (EPA, 1998).

For FGD applications, the slurry combines with the SO2-laden waste gas to form a waste slurry in the bottom
of the scrubber. The sludge is removed from the scrubber and, depending upon the reagent or sorbent used
to react with the SO2, the waste reacted  sludge is disposed of, recycled or regenerated, or, in some cases a
salable product. For slurries which produce calcium sulfate and sulfite, oxidizing the waste sludge results in
gypsum.   Gypsum is a preferred product because it can be marketed and also because  of its superior
dewatering characteristics. Most scrubbers are operated without the oxidizing step and the waste sludge must
be dewatered and disposed of properly. Some slurries can  be regenerated and used again, but few such
systems are in use due to high energy costs associated with the regeneration of the reagent (Sondreal, 1993;
Soud, et al.,  1993; Merrick,  1989).

Configuring a control  device that optimizes control of more than one pollutant often does not achieve the
highest control possible for any of the pollutants controlled alone. For this reason, waste gas flows which
contain multiple pollutants (e.g.,  PM  and SO2,  or PM and inorganic gases) are generally  controlled with
multiple control devices, occasionally more than one type of wet scrubber (EC/R, 1996).

References:

AWMA,  1992.  Air& Waste Management Association, Air Pollution Engineering Manual, Van Nostrand
Reinhold,  New York.

Avallone, 1996. "Marks' Standard Handbook for Mechanical  Engineers," edited by Eugene Avallone and
Theodore  Baumeister, 10th Edition, McGraw-Hill, New York, NY, 1996.

Cooper, 1994. David Cooper and F. Alley, Air Pollution Control: A Design Approach, 2nd Edition,
Waveland  Press, Prospect Heights, IL, 1994.

Corbitt, 1990. Standard Handbook of Environmental Engineering, edited by Robert A. Corbitt, McGraw-
Hill, New York, NY, 1990.

EC/R, 1996.  EC/R, Inc., "Evaluation of Fine Particulate Matter Control Technology:  Final Draft," prepared
for U.S. EPA, Integrated Policy and Strategies Group, Durham, NC, September, 1996.

EPA, 1973.  U.S. EPA, "National  Emissions Data System Control Device Workbook," APTD-1570,
Research  Triangle Park, NC, July, 1973.

EPA, 1981.  U.S. EPA, Office of Research and Development, "Control Techniques for Particulate
Emissions from Stationary Sources - Volume 1," EPA-450/3-81-005a, Research Triangle Park,  NC,
September, 1982.


EPA-CICA Fact Sheet                          5                          Spray-Tower Scrubber

-------
EPA, 1982. U.S. EPA, Office of Research and Development, "Control Techniques for Particulate
Emissions from Stationary Sources - Volume 1," EPA-450/3-81-005a, Research Triangle Park, NC,
September, 1982.

EPA, 1991. U.S. EPA, Office of Research and Development, "Control Technologies for Hazardous Air
Pollutants," EPA/625/6-91/014, Washington, D.C., June, 1991.

EPA, 1992. U.S. EPA, Office of Air Quality Planning and Standards, "Control Technologies for Volatile
Organic Compound Emissions from Stationary Sources," EPA 453/R-92-018, Research Triangle Park,
NC, December, 1992

EPA, 1993. U.S. EPA, Office of Air Quality Planning and Standards, "Chromium Emissions from
Chromium Electroplating and Chromic Acid Anodizing Operations - Background Information for Proposed
Standards," EPA-453/R-93-030a, Research Triangle Park, NC, July, 1993.

EPA, 1995. U.S. EPA, Office of Air Quality Planning and Standards, "Survey of Control Technologies for
Low Concentration Organic Vapor Gas Streams," EPA-456/R-95-003, Research Triangle Park, NC, May.

EPA, 1996. U.S. EPA, Office of Air Quality Planning and Standards, "OAQPS Control Cost Manual," Fifth
Edition, EPA 453/B-96-001, Research Triangle Park, NC, February, 1996.

EPA, 1998. U.S. EPA, Office of Air Quality Planning and Standards, "Stationary Source Control
Techniques Document for Fine Particulate Matter," EPA-452/R-97-001, Research Triangle Park, NC,
October, 1998.

Merrick, 1989. David Merrick and Jan Vernon, "Review of Flue Gas Desulphurization Systems,"
Chemistry and Industry, February 6 ,  1989.

Perry, 1984. "Perry's Chemical Engineers' Handbook," edited by Robert Perry and Don Green, 6th Edition,
McGraw-Hill, New York, NY, 1984.

Sondreal, 1993.  Everett A. Sondreal, "Clean Utilization of Low-Rank Coals for Low-Cost Power
Generation," from "Clean and Efficient Use of Coal: The New Era for Low-Rank Coal," Organization for
Economic Co-Operation and Development/International Energy Agency, Paris,  France, 1993.

Soud, et al., 1993.  Hermine N. Soud, Mitsuru Takeshita, and Irene M. Smith, "FGC Systems and
Installations for Coal-Fired Plants" from "Desulfurization 3," Institution of Chemical Engineers,
Warwickshire, UK,  1993.
EPA-CICA Fact Sheet                           6                          Spray-Tower Scrubber

-------