United States       Office of Ground Water       EPA/816-R-99-014o
Environmental       and Drinking Water (4601)     September 1999
Protection Agency
The Class V Underground Injection
Control Study
Volume 15

Experimental Technology Wells

-------
                                  Table of Contents
                                                                                     Page

1.      Summary	1

2.      Introduction	2

3.      Experimental Tracer Study Wells  	5
       3.1     Prevalence of Wells 	6
       3.2     Injectate Characteristics and Injection Practices 	8
              3.2.1   Injectate Characteristics	8
              3.2.2   Well Characteristics and Operating Practices  	9
       3.3     Potential and Documented Damage to USDWs 	20
              3.3.1   Injectate Constituent Properties 	21
              3.3.2   Observed Impacts	21
       3.4     Best Management Practices	22
       3.5     Current Regulatory Requirements	23
              3.5.1   Federal Programs	23
              3.5.2   State and Local Programs  	25

4.      Experimental ATES System Wells	26
       4.1     Prevalence of Wells 	26
       4.2     Injectate Characteristics and Injection Practices 	27
              4.2.1   Injectate Characteristics	27
              4.2.2   Well Characteristics and Operating Practices  	27
       4.3     Potential and Documented Damage to USDWs 	33
              4.3.1   Injectate Constituent Properties 	33
              4.3.2   Observed Impacts	34
       4.4     Best Management Practices	35
       4.5     Current Regulatory Requirements	37
              4.5.1   Federal Programs	37
              4.5.2   State and Local Programs  	37

Attachment A: State and Local Program Descriptions  	38

References	48
September 30,  1999

-------
                 EXPERIMENTAL TECHNOLOGY WELLS
       The U.S. Environmental Protection Agency (USEPA) conducted a study of Class V
underground injection wells to develop background information the Agency can use to evaluate the risk
that these wells pose to underground sources of drinking water (USDWs) and to determine whether
additional federal regulation is warranted. The final report for this study, which is called the Class V
Underground Injection Control (UIC) Study, consists of 23 volumes and five supporting appendices.
Volume 1 provides an overview of the study methods, the USEPA UIC Program, and general findings.
Volumes 2 through 23 present information summaries for each of the 23 categories of wells that were
studied (Volume 21 covers 2 well categories).  This volume, which is Volume 15, covers Class V
experimental technology wells.

1.     SUMMARY

       Experimental technology injection wells have been reported in seven states and are used  to test
new or unproven technologies.  Experimental "tracer study" wells, which inject chemical tracers for the
purpose of studying ground water and hydrogeologic parameters, comprise the vast majority of wells
classified as experimental wells for the purpose of this study.  Experimental technologies also have been
recently applied in Class V wells associated with Aquifer Thermal Energy Storage (ATES)  systems,
which store thermal energy by injecting heated and/or cooled water into an aquifer. The existence of
experimental wells varies widely from state to state because, in some instances, different definitions of
"experimental well" are used by different states. The definitions used by the states may not necessarily
correspond to the USEPA definition of experimental well that was included the Class V study
questionnaire.

       Experimental Tracer Study Wells

       Many different types of substances are injected into experimental tracer study wells. Examples
of these substances include organic dyes, inert gases, short half-life radionuclides, rare earth metals, and
inorganic or organic compounds.  Only one experimental well was reported for which injectate did not
meet the primary maximum contaminant levels (MCLs), secondary MCLs, and health advisory levels
(HALs), this being the tracer study well  at the Naturita, Colorado site, where contaminated native
ground water was used as a tracer carrier.  The injectate for this tracer well exceeded MCLs for
sulfates and chloride, and contained arsenic and molybdenum at levels greater than HALs.

       The injection zone characteristics for experimental technology injection wells vary widely
depending upon the purpose of the well. Wells used for tracer studies may inject into contaminated
aquifers, sometimes including aquifers that serve as drinking water supplies.

       No contamination incidents were reported for experimental tracer study wells. In addition,
experimental tracer study wells are not vulnerable to illicit discharges because injectate quality is
September 30, 1999

-------
controlled by the conditions of the experiment being conducted. Tracer study wells generally release
tracers in small quantities.

       According to the state and USEPA Regional survey conducted for this study six states have a
total of 396 documented experimental tracer study wells:  South Carolina, Colorado, Nevada, Idaho,
Texas, and Washington.  More than 97 percent of the documented tracer study wells exist in South
Carolina (207 wells or 52%) and Nevada (179 wells or 45%). Most of the tracer study wells in South
Carolina and Nevada are being operated at U.S. Department of Energy facilities.  The States of
Massachusetts, Florida, and Mississippi indicated that they may have experimental wells, but that they
could not provide an estimate of how many actually exist.  The Texas and Washington UIC programs
identified five and two experimental wells operating in their states, respectively, but did not provide any
information concerning the types of wells (they may in fact be something other than tracer study wells).
The Illinois UIC program reported two experimental wells that are most likely no longer operating.
Survey responses from the other states indicated that they had no experimental wells.

       The experimental technology wells in South Carolina, Nevada, and Washington are individually
permitted by the state. Idaho authorizes shallow injection wells (<18 feet deep) by rule, provided that
inventory information is supplied and use of the well does not result in contamination of a USDW.
Deep injection wells (>18 feet deep) in Idaho must obtain an individual permit.  Experimental wells in
Texas and Colorado are permitted by rule, but the wells in Colorado must have a construction permit.

       ATES System Wells

       Heated or cooled process water, which may originate from native ground water, surface water,
or potable water, are injected into aquifers for ATES systems. Experimental ATES wells inject water
into the same aquifer from which it was withdrawn.  While no contamination incidents were reported for
ATES system wells, several reports mentioned that the concentration of constituents in ground water
receiving fluids from some ATES wells were higher than background levels. Experimental ATES
system wells are not vulnerable to illicit discharges because injectate quality is controlled by the
conditions of the process operation. In particular, experimental ATES systems inject treated water for
which injectate  quality must be controlled. No UIC programs reported any operating ATES system
wells in the survey responses.  ATES systems, however, were recently operated in Minnesota and
New York, and are in operation in several European countries.

2.    INTRODUCTION

       Under the existing UIC Program regulations in 40 CFR 146.5(e), Class V injection wells
include "injection wells used in experimental technologies."  Experimental technology is defined in 40
CFR 146.3 as "a technology which has not been proven feasible under the conditions in which it is
being tested." As part of this study, USEPA conducted a survey of state and USEPA Regional staff
who administer Class V UIC programs in order to collect information on experimental technology
wells. Unfortunately, the UIC program personnel who identified "experimental wells" in their survey
responses did not use the same criteria to classify these types of wells, and in some cases, did not apply

September 30, 1999                                                                         2

-------
the definition of experimental well that appeared on the survey questionnaire itself.  The questionnaire
defined "experimental well" as follows:

       DEFINITION'. Experimental wells are used to test new technologies. Wells will not be
       classified as experimental if the technology can be considered under an established well
       subclass. For example, a well used for bioremediation will be classified as an aquifer
       remediation well.

       Despite this intended definition, the survey respondents classified many different types of wells
as experimental.  For example, certain state UIC programs included injection wells used for dye tracer
studies in the experimental well category while other programs did not identify tracer study wells as
experimental wells.  Tracer study wells are used to conduct experiments (e.g., characterization of
aquifers); however, the tracer study well technology itself is generally not considered an experimental
technology, and would therefore not fit the USEPA definition of an experimental well. Other survey
respondents included "experimental" solution mining, aquifer remediation, food processing, or aquifer
storage and recovery injection wells in the experimental well category. However, these wells are not
true experimental wells under the USEPA experimental well definition, either because they are not
intended to test new injection technologies or because they fit within another established well subclass.
For the purposes of this volume, wells that were identified by UIC programs as "experimental wells"
were recategorized if another Class V sub-category appeared to be more appropriate. In other words,
wells that USEPA believes are better classified under one of the other Class V well types - even if
considered experimental by the survey respondents - are not discussed in this volume, but are
discussed in the volume for the appropriate well type.

       To be more specific, the following sections identify the different kinds of wells classified as
experimental by  the survey respondents and describe where and how they are covered the Class V
Study.

       Tracer Study Wells

       Some UIC Programs identified tracer study wells as experimental wells since these wells
injected ground water tracers (also called tracer tests). Other programs, however, did not identify
these wells as experimental wells. A ground water tracer is "matter or energy carried by ground water
which will give information concerning the direction of movement and/or velocity of the water and
potential contaminants which might be transported by the water....  Tracers can also help with the
determination of hydraulic conductivity, porosity, dispersivity chemical distribution coefficients, and
other hydrogeologic parameters" (Davis, et. al., 1986 as cited in Holmbeck-Pelham, 1998).  While
tracers may exist in the subsurface due to natural or anthropogenic reasons, in the context of this
discussion the only tracers that are relevant are those deliberately introduced through injection wells.

       Tracer study wells may not be considered experimental wells under the USEPA definition, as
these wells are not intended to test new injection technologies. However, tracer study wells do not fit
September 30, 1999

-------
neatly into any other well category discussed in this report. Therefore, tracer study wells are discussed
in Section 3 of this volume.

       Aquifer Thermal Energy Storage Wells

       An aquifer thermal energy storage (ATES) system stores thermal energy by injecting heated
and/or cooled water into an aquifer. This energy can then be used at a later time. ATES system
injectate (whether heated or cooled) generally is returned to the same aquifer from which it was
previously withdrawn; however, in some cases, the injectate may have come from a different aquifer or
from surface water.  The heated or cooled water stored in the aquifer can be reused (for heating or
cooling) by pumping the water to the surface.

       Although no active ATES systems were identified in the survey, experimental ATES systems
were recently operated in Minnesota and New York (Marseille and Wicke, 1992; Hoyer, et. al.,
1994). ATES system wells are considered experimental injection wells because they are designed to
test new injection technologies. These systems are discussed in Section 4 of this volume.

       Solution Mining Wells

       The Arizona and Colorado UIC programs identified injection wells as experimental wells since
these wells tested innovative solution mining technologies. Solution mining involves injecting a fluid
(e.g., sulfuric acid or sodium bicarbonate) into an underground mineral formation through an injection
well, and then extracting the mineral-laden fluid through a recovery well for further processing to
recover the mineral of interest. In the past, solution mining wells operated for experimental purposes
have been rule authorized as Class V injection wells, while solution mining wells operated for
commercial purposes may be permitted as Class HI injection wells.

       Although these wells have been handled this way in the past, USEPA now believes such wells
are more appropriately classified as Class m solution mining wells. In fact,  the only remaining solution
mining well that was initially regulated as a Class V experimental well has been, or is in the process of
being, permitted as a Class m well.  In the future, all such wells will also be permitted as Class m
wells. Therefore, these wells are  not considered in this Class V Study.  Volume 12 covers other
solution mining wells that qualify as Class V wells.

       Experimental Aquifer Remediation Injection Wells

       Several UIC programs identified innovative aquifer remediation technologies as experimental
wells.  For example, the survey respondents identified the following experimental aquifer remediation
technologies:

       Chlorine for remediation of aquifer bacterial contamination;
       Ethanol for remediation of aquifer nitrate contamination;
•      Calcium polysulfide for remediation of aquifer hexavalent chromium contamination;


September 30, 1999                                                                         <•

-------
       Ground water to prevent migration of contaminants in aquifers; and
       Gas-phase or aqueous-phase nutrients for studies of experimental ground water in situ
       bioremediation systems.

       For this study, aquifer remediation wells identified as "experimental" by survey respondents are
not considered experimental because they do not test new injection technologies.  Instead, they are
covered along with other aquifer remediation wells in \blume 16 of this report.

       Aquifer Storage and Recovery Injection Wells

       The Tennessee UIC Program identified one injection well as an experimental well. This well is
used by a municipal water company for drinking water storage. Aquifer storage and recovery wells are
used to emplace and then retrieve drinking water from  an aquifer.  Typically, ground water (or surface
water) is treated to drinking water standards and is injected back into an aquifer. The treated water is
then retrieved during times of high water usage for distribution to customers.

       The Tennessee UIC Program indicated that this injection well was permitted as an experimental
well because, although aquifer storage and retrieval system technology has been demonstrated in other
states, this is the first such system to be constructed in  Tennessee. However, USEPA believes this well
is the same as other such wells throughout the nation, and therefore covers it along with other aquifer
storage and recovery wells in Volume 21 of this study.

       Food Processing Wells

       The West Virginia UIC Program reported that one experimental injection well is operating
within the state. This well, which is located at a goat cheese factory, consists of a drain field that
contains wood chips.  The state reported that this well was classified as an experimental well because it
did not fit into any other state program category.  However, USEPA considers this to be a food
processing well and covers it along with other such wells in Volume 6 of this report.

3.     EXPERIMENTAL TRACER STUDY WELLS

       This section provides the following information on experimental tracer study wells:
(1) prevalence; (2) injectate characteristics and well  operating practices; (3) potential and documented
impacts on USDWs; (4) practices for effectively installing, operating, and removing tracer study wells;
and (5) federal, state, and local programs governing the installation, operation, and removal of this well
type.
September 30, 1999

-------
       3.1    Prevalence of Wells

       For this study, data on the number of tracer study wells were collected through a survey of state
and USEPA Regional UIC programs. The survey methods are summarized in Section 4 of \blume 1
of the Class V Study.  Table 1 lists the number of experimental tracer study wells in each state by
USEPA Region,  as determined from the survey using the categorizations described above in Section 2.
The table includes the documented and estimated number of tracer study wells in each state, along with
the source and basis for any estimate, when noted by the survey respondents. If a  state is not listed in
Table 1, it means that the UIC program responsible for that state indicated that no tracer study wells
are currently operating in the state. As described above, wells that were originally identified by UIC
programs as "experimental" were reclassified if the wells were better addressed under another
established injection well category. Table 1 does not include these particular wells.

       As shown in Table 1, a total of 396 documented Class V experimental tracer study wells have
been identified. None of the UIC programs reported "estimated"  numbers for experimental tracer
study wells.  However, Florida, Massachusetts, and Mississippi reported that the true inventory of
experimental wells is "unknown." The Texas and Washington UIC programs provided no information
on the nature or purpose of the experimental wells existing in their states.

       There may be considerable temporal variation in the tracer study well inventory data
because, unlike some of the other Class V injection well categories, tracer study wells have a limited
operating life.  Operating permits or rule authorizations for tracer study wells generally expire at the
conclusion of the experiment being conducted (e.g., when a tracer study for aquifer characterization is
concluded).  The duration of operating permits and rule authorizations for tracer study wells reported in
the survey responses ranged in duration from two months to 10 years. Therefore, the numbers
reported in Table 1 may be considered only as a "snapshot" of the tracer study well inventory.

       Of the 396 operating Class V experimental tracer study wells, 179 are in Nevada and 207 are
in South Carolina.  These two states  account for more than 97 percent of the documented experimental
wells in the U.S.  All of the experimental tracer study wells reported by the Nevada UIC program are
associated with the proposed Micca Mountain High Level Radioactive Waste Repository Site
Characterization Project (YMSCP) operated by the U.S. Department of Energy (DOE). Some of
these 179 wells at the Micca Mountain site have reportedly been plugged  and abandoned.  In addition,
nearly all of the experimental wells documented in South Carolina are tracer study wells or aquifer
remediation injection wells associated with environmental remediation projects at the DOE Savannah
River Site.  The survey questionnaire for South Carolina did not identify how many of the wells are
tracer study wells and how many are  aquifer remediation wells. Because no  additional information is
available concerning the purpose of the experimental wells reported  by the South Carolina UIC
program, all of South Carolina's wells are included in the tracer study well inventory.
September 30, 1999

-------
            Table 1. Inventory of Experimental Tracer Study Wells in the U.S.
State
Documented
Number of Wells
Estimated Number of Wells
Number
Source of Estimate and Methodology
USEPA Region 1
MA
0
Unknown
NA
USEPA Region 2 - None
USEPA Region 3 - None
USEPA Region 4
FL
MS
SC
0
0
207
Unknown
Unknown
207
NA
NA
Permit Program Data.
USEPA Region 5
IL
0
NR
Permit Program Data. Two experimental wells reported to be used to inject
compressed air are believed no longer to be operating.
USEPA Region 6
TX
5
NR
Permit Program Data. The Texas UIC program reported 5 experimental wells
in the state, but provided no information concerning the purpose of the wells.
USEPA Region 7 - None
USEPA Region 8
CO
2
NA
Permit Program Data.
USEPA Region 9
NV
179
179
Permit Program Data.
USEPA Region 10
ID
WA
1
2
1
NR
IDWR Injection Well Permit Application No. 63-W-47, October 26, 1990,
provided by Ms. Jane Talllman, Idaho Department of Water Resources.
Permit Program Data. The Washington UIC program reported 2 experimental
wells in the state, but provided no information concerning the purpose of the
wells.
All USEPA Regions
All States
396
>396
Total estimated number counts the documented number when the estimate is
unknown or NR.
NA Not available
NR Although USEPA Regional or state officials reported the presence of the well type, the estimated number of wells was
not reported.
Unknown Questionnaire completed, but number of wells is unknown
September 30, 1999

-------
       Two state UIC programs - Colorado and Idaho - reported one or two operational Class V
experimental tracer study wells. Altogether, these programs comprise less than 1 percent of the documented
tracer study wells in the nation.

       The Colorado UIC Program reported two operational experimental tracer study wells. One well is
being operated at an experimental mining operation in Idaho Springs, Colorado.  The Colorado UIC
program also reported three "experimental" aquifer remediation wells and one "experimental" solution mining
well that have been recategorized for the purpose of this study, as described in Section 2.

       The Idaho UIC Program reported that one experimental well is being operated in Eagle Island State
Park by Boise State University (as part of a university graduate student research project).  This project
involves the construction of both a tracer injection well and monitoring wells used to study ground water
contaminant migration in shallow aquifers.

       3.2    Injectate Characteristics and Injection Practices

       The following sections describe the injectate characteristics and injection practices for experimental
tracer study wells.

       3.2.1   Injectate Characteristics

       Tracers used for injection well experiments may include organic dyes, rare earth metals, and other
organic and inorganic compounds (e.g., rare earth metals, Rhodamine WT dye, chloride, bromide, and
organic solutes) (Holmbeck-Pelham, 1998). Short half-life radioisotopes may also be used as long as the
likelihood of contaminating drinking water is extremely low, or the site is already contaminated with
radionuclides. For some tracer study wells, only general information is available concerning injectate
characteristics. For these wells, examples of tracers and injectate data are presented below

•      Boise State University Department of Geology. The permit issued by the Idaho Department of
       Water Resources for the injection well tracer study limits the injectate to heated ground water
       derived from the same aquifer from a nearby well (IDWR, 1990).  The project description in the
       permit application indicates that tracer solutions of chloride and bromide ions would be used in the
       tracer test (BSU,  1990). However, neither the permit application nor the permit for the injection
       well included any concentration data for the tracer solutions or identified the specific chloride and
       bromide ion compounds used in the tracer well tests.

•      Bureau of Mines Stope Leaching Project Tracer Study.  The U.S. Department of the Interior,
       Bureau of Mines (BOM) submitted an application in 1992 for authorization to inject potable water
       and sodium chloride (NaCl) tracer into a man-made fractured crystalline rock mass at the Colorado
       School of Mines (CSM) Experimental Mine Facility in Idaho Springs, Colorado. In all three tests,
       the injectate (potable water provided by the Idaho Springs Municipal Water Department) was
       mixed with a NaCl tracer. The concentration of NaCl in the injectate was 7,000 ppm, 3,000 ppm,
       and 6,000 ppm during the three tests.


   September 30,  1999                                                                          8

-------
       Naturita Uranium Site Tracer Study.  In 1998, the United States Geological Survey (USGS)
       applied for approval to conduct a small-scale tracer study of an aquifer in Colorado contaminated
       with uranium, vanadium, sodium chloride, sodium bicarbonate, sulfuric acid, and ammonium sulfate.
       The USGS applied for approval to conduct five tracer tests at the Naturita site. Each test would
       inject native ground water with 1,000 ppm potassium bromide (ppm as bromide) into the aquifer.
       The native ground water used as a tracer carrier is contaminated with uranium, chloride, and sulfates
       at levels greater than drinking water maximum MCLs, and with molybdenum and arsenic at levels
       greater than HALs.  Concentrations of strontium in the native ground water are also elevated above
       background concentrations. Native ground water (i.e., tracer carrier) quality data are summarized in
       Table 2 (USGS, 1999).

•      Yucca Mountain Site Characterization Project (YMSCP). Although many other chemicals are
       being used (e.g., helium, lithium bromide, synthetic colloids, and short half-life radionuclides), the
       most commonly injected tracer for YMSCP tracer study wells is sulfur hexafluoride gas.  Tracers
       approved by the Nevada UIC program for the Yucca Mountain project are shown in Table 3.  Not
       all of these tracers have been used.

       During 1996 and 1997, the YMSCP injected sulfur hexafluoride to conduct tracer and ventilation
       testing at the site (USDOE, 1996). Additionally, lithium bromide was mixed with water and was
       used as a tracer to tag construction, dust control,  and drilling water. Other tracers used in testing at
       the YMSCP include sodium iodide, pentafluorobenzoic acid (PFBA), and fluorescent microspheres.

       3.2.2  Well Characteristics and Operating Practices

       Examples of well characteristics and operating practices for tracer study wells are presented below.

       Bureau of Mines Slope Leaching Project Tracer Study

       The BOM conducted three tracer tests at the stope leaching research project. The research project
involved the control of fluids released into a simulated stope filled with fractured rock.1 The fractured rock
was formed by blasting the in-place rock  mass and by creating associated fracture patterns in the
surrounding bedrock. While some fluid introduced into the formation is lost in the fractures, the remaining
fluid is collected and recycled back into the formation for the duration of the tracer study (BOM, 1993).
       1 A stope is an excavation in the form of steps made by the mining of ore from steeply inclined or
   vertical veins.
   September 30, 1999

-------
       Table 2. Summary of Native Ground Water (Tracer Carrier) Analyses at the
                        Naturita Site 1989 -1994 (USGS, 1998)
Parameter
Aluminum
Ammonium
Antimony
Arsenic
Barium
Boron
Bromide
Cadmium
Calcium
Chloride
Chromium (total)
Cobalt
Copper
Cyanide
Fluoride
Iron
Lead (at tap)
Magnesium
Mercury (inorganic)
Molybdenum
Nickel
Nitrate (as N)
Phosphate
Potassium
Selenium
Silica
Silver
Sodium
Strontium
Background Ground
Water Quality
(mg/1)
O.09
<0.10
<0.003
O.01
<0.1
0.1
<0.1
<0.001
155
8.2
0.01
O.05
O.02
O.01
0.3
0.03
O.01
0.01
O.0002
0.01
O.04
1.7
0.1
1.9
O.005
O.005
0.01
48
1.2
Onsite Ground
Water Quality
(mg/1)
O.10
0.26
O.003
0.03
O.I
0.2
0.4
O.001
243
546
0.01
O.05
O.02
O.01
1.4
0.05
O.01
5.1
O.0002
0.29
O.04
2.7
0.4
41
0.01
0.01
0.01
997
5.5
MCL (mg/1)
0.05-0.2 (S)
--
0.006
0.05
2.0
--
--
0.005
--
250.0 (S)
0.1
--
1.3
0.2
4.0
0.3
0.015
--
0.002
--
0.1
10.0
--
--
0.05
--
0.1 (S)
--
--
HAL (mg/1)
--
--
0.003 (NC)
0.002 (C)
2.0 (NC)
0.6 (NC)
--
0.005 (NC)
--
--
0.1 (NC)
--
--
0.2 (NC)
--
--
--
--
0.002 (NC)
0.04 (NC)
0.1 (NC)
--
--
--
--
--
0.1 (NC)
--
17.0 (NC)
September 30, 1999
10

-------
            Table 2.  Summary of Native Ground Water (Tracer Carrier) Analyses at the
                                Naturita Site 1989 -1994 (USGS, 1998)
                                              (Continued)
Parameter
Sulfate
Suffide
Thallium
Tin
Uranium
Vanadium
Zinc
Background Ground
Water Quality
(mg/1)
348
0.1
O.01
<0.005
0.012
<0.01
0.057
Onsite Ground
Water Quality
(mg/1)
1200
0.1
O.01
O.005
2.2
6.4
0.005
MCL (mg/1)
500.0
--
0.002
--
0.02
--
5.0(S)
HAL (mg/1)
--
--
0.0005 (NC)
--
-
--
2.0 (NC)
— means no MCL or health advisory level specified
(S) means the reported value is a secondary MCL (no notation means the value is a primary MCL)
(NC) means the reported health advisory level is for non-cancer effects
( C ) means the reported health advisory level is for a 104 cancer risk
   September 30, 1999
11

-------
Table 3. Nevada UIC-Approved Tracers for Yucca Mountain Site Characterization Project, Yucca
                                             Mountain, Nevada
    NV UIC Approved Tracers for the Yucca Mountain
                        Project
   Pyridone
   Sodium Chloride
   Lithium Bromide
   Fluorescent Microspheres
   Polystyrene Spheres
   Sulfur Hexafluoride (SF6) - gaseous tracer
   Nitrogen
         " Cold-MP (tetra-fluorethane) (gas)
   2,4,6- Trifluorobenzoic Acid
   2,4,5- Trifluorobenzoic Acid
   2,3,4- Trifluorobenzoic Acid
   2,3,6- Trifluorobenzoic Acid
   2,3,4,5- Tetrafluorobenzoic Acid
   2,3,4,6- Tetrafluorobenzoic Acid
   3,4,5-Trifluorobenzoic Acid
   2,3- Difluorobenzoic Acid
   2,4-  Difluorobenzoic Acid
   2,5-  Difluorobenzoic Acid
   2,6-  Difluorobenzoic Acid
   3,4-  Difluorobenzoic Acid
   3,5-  Difluorobenzoic Acid
   Pentafluorobenzoic Acid
        NV UIC Approved Tracers per 1996
                  Modification
Sodium Tungstate Dihydrate
Sodium Molybdate Dihydrate
Sodium Fluoride
Fluorescein, sodium derivative
Potassium Fluoride
Magnesium Fluoride
Magnesium Iodide
Helium
Neon
Krypton
Xenon
Argon
Sodium Iodide
Sodium Bromide
Potassium Iodide
Potassium Bromide
  September 30, 1999
                                              12

-------
       Three tracer tests were conducted in a stope filled with fractured rock, into which tracer fluid was
injected.  This research project involved the filling of the stope with tracer fluid, which subsequently flowed
into the fractured rock.  The Situation Statement for the project approved the use of cementious grout and
superplasticizer for the control of water flow in the rock fractures. A USEPA Region 8 lexicologist
indicated that these grouting materials are lexicologically insignificant (BOM, 1993).  After the tracer tests
were initiated, the BOM requested and obtained approval to use alternative grouting materials, including
"Hey'di Special System" and "Hey'di K-ll" waterproofing grouts (USEPA Region 8,  1993a; BOM,
1993 a).

       The first tracer test was conducted by injecting approximately 4,000 gallons of potable water with
7,000 ppm of NaCl tracer into the man-made fracture formation (stope). The injectate  flowed through the
stope and exited through a bulkhead, and then flowed through a pipe to a sump.  Samples were taken from
the pipe before the water reached the sump. The NaCl tracer was detected in fluids  at a concentration
ranging between 1,000 and 1,500 ppm NaCl.  Approximately 3,000 gallons of tracer fluid were lost through
fractures adjacent to the bulkhead. Almost all of the lost fluid was recovered in the sump and was
transported to the Idaho Springs Municipal Waste Water Treatment Plant for disposal.  On three different
occasions, the stope was flushed with 4,000 gallons of potable water without any tracer to dilute the tracer
in the fractures and to test the grouting measures used to seal the leaking fractures. This first tracer test
resulted in considerable fluid loss through the fractures.  As a result, the leaking fractures were surface
grouted both inside and outside the stope with Portland cement grout and Hey'di waterproofing grouts
(BOM, 1993a; BOM 1993b).

       The second tracer test was conducted using a total of 8,000  gallons of potable  water with 3,000
ppm of NaCl tracer. The water samples used for this test were obtained from the same locations as were
the samples in the first tracer test and were analyzed for certain constituents (BOM, 1993b).

       The third tracer test and a constant head test were completed in September 1994. Water samples
were taken during this test at the same locations as during the first and second tests. A total of 8,114 gallons
of potable water with 6,000 ppm NaCl tracer was injected into the stope.  After the test's conclusion, in
May 1994, a total of 3,603 gallons of fluid were recovered in the sump.  The stope was subsequently
flushed with 8,185 gallons of potable water without tracer. Over a period of about four months, USEPA
Region 8 approved the reuse of the tracer solutions in drilling operations, and required that the concentration
of the tracer solution be diluted to no greater than 1,000 ppm NaCl prior to  reuse (USEPA Region 8,
1994).

       USEPA limited the concentration of the sodium chloride tracer to no more than 7,000 ppm and
required that BOM analyze fluid samples from the system sump for several constituents. Analyses were
required prior to the beginning of the tracer test, two months  after the beginning of the tracer test, and
quarterly, thereafter. Ten samples were taken during the first tracer test, and  analytical results are shown in
Table 4 (these data are representative of the injectate and ground water).
   September 30, 1999                                                                         13

-------
                            Table 4. Analytical Data for Recovered Injectate - BOM Stope Leaching Project

Parameter
Arsenic
Cadmium
Copper
Lead
Mercury
Zinc
Silver
Gross Alpha
(pCi/L)
Gross Beta
(pCi/L)

Parameter
Fluoride
Sulfate (SO4)
Sample Number
10-1
0.005
0.005
0.18
0.010
0.0011
0.72
<0.0001
90 +/- 25
64+7- 15
10-2
0.005
0.005
0.046
0.006
0.0002
0.28
0.0001
23 +/- 13
25 +/- 10
10-3
0.005
0.019
0.53
0.035
0.0026
3.3
0.0001
320 +/-
40
170+/-
20
Sample Number
2-1
0.5
470
2-2
1.1
780
1-1
0.5
450
10-4
0.005
0.016
0.52
0.030
0.0012
3.4
0.0001
300 +/-
50
160+/-
20
10-5
0.005
0.016
0.40
0.040
0.0008
3.9
0.0001
280 +/-
40
140 +/-
20
10-6
0.005
0.009
0.16
0.085
0.0010
2.7
0.0001
130+/-
30
81 +/- 17
10-7
0.005
0.014
0.49
0.034
0.0006
3.7
0.0001
340 +/-
50
170+/-
20
10-8
0.006
0.017
0.52
0.042
0.0006
3.6
0.0001
340 +/-
50
180+/-
20
10-9
0.005
0.017
0.51
0.026
0.0005
3.5
0.0001
360 +/-
50
160+/-
20
10-10
0.005
0.016
0.53
0.030
0.0029
3.6
0.0001
290 +/-
40
170 +/-
20
1-1
0.005
0.005
0.005
O.005
O.0001
1.2
0.0002
19+/-20
30+/-31
MCL
(mg/1)
0.05
0.005
1.3
0.015
0.002
5.0 (S)
0.1 (S)
15.0
--




















4.0
500.0
- means no discharge limit, MCL, or health advisory level specified
(S) means the reported value is a secondary MCL (no notation means the value is a primary MCL)
   September 30, 1999
14

-------
       USGS Naturita Uranium Site Tracer Study

       Each of the five proposed tests at this site, introduced in Section 3.2.1, would inject 50 gallons of
native ground water with 1,000 ppm potassium bromide tracer into the aquifer. Monitoring would be
conducted at two existing monitoring wells and 12 newly installed wells at the site.  The USGS reported that
injection and monitoring wells would be installed approximately 150 yards from the San Miguel River.  The
river recharges the alluvial aquifer during high water season, while the aquifer discharges to the river during
the low water season. Unconfmed ground water occurs in the alluvial aquifer at depths ranging from zero to
18 feet below ground surface (USGS,  1998). The USGS predicted that the tracer tests would result in
elevated concentrations of potassium (K+) and bromine (Br-). Local ground water concentrations of K+
would increase from approximately 40 mg/1 to 540 mg/1, and local concentrations of Br- would increase
from less than  5 mg/1 to 1,000 mg/1.  Bromide concentrations in the aquifer would be comparable in
magnitude to concentrations of sodium and sulfate in the aquifer, prior to any dispersion (USGS, 1998).
The USGS did not provide any information concerning well characteristics or operating data for the
experimental well operation.
       Boise State University Department of Geology

       A diagram of the injection well in use at the Boise State University (BSU) tracer study site is shown
in Figure 1.  The well has a 4.5 inch diameter Schedule 40 PVC casing slotted from 8 feet deep to 38 feet
deep, with a vented cap and a concrete and granular bentonite seal to 6 feet deep.  The well is 6 inches in
diameter. In the permit application for the proposed injection well, BSU requested exemption from a
requirement to install 18 feet of steel surface casing (BSU, 1990).

       Heated ground water containing chloride or bromide ions (i.e., the tracers) is injected into this well.
The ground water containing the injected tracer solution is withdrawn from the aquifer through monitoring
wells to determine the flow characteristics of the aquifer. The permit issued by the Idaho Department of
Water Resources limits the flow of injectate into the injection well to no more than 10 gallons per minute  on
a weekly average, and limits the source of the injectate to heated ground water taken from  a water
production well located in the same  aquifer zone as the injection well.

       Yucca Mountain Site Characterization Project

       The YMSCP is studying the hydrological and geological properties of rock formations around
Yucca Mountain.  Three wells are injecting tracers to study hydrological characteristics of the saturated
zone. Three more wells may be constructed, if necessary.  Other injection wells and boreholes are injecting
approved tracers to tag the drilling water or air. The tracers will allow project managers to identify water or
air from ground water and gas sources other than the water or air being injected into the well  (Land, 1997).
   September 30, 1999                                                                          15

-------
 Figure 1. Schematic Diagram of Tracer Study Injection Well, Boise State University Department
                                            of Geology
Source: BSU, 1990
       During 1996, YMSCP researchers injected 4.6 ft3 of sulfur hexafluoride to conduct tracer and
ventilation testing at the site (USDOE, 1996).  Additionally, 30,465 ounces of lithium bromide were mixed
with 9,374,000 gallons of water. The mixture was used to tag construction, dust control, and drilling water.
Other tracers used for this test include sodium iodide, pentafluorobenzoic acid (PFBA), and fluorescent
microspheres.

       During 1997, YMSCP scientists continued using sulfur hexafluoride as a tracer in
drilling and testing activities at the site (USDOE, 1997a).  The total annual amount of this tracer used in
operations, drilling activities,  and testing activities is approximately 215,000, 38, and 215,000 ft3,
respectively.
   September 30, 1999
16

-------
       During 1997, researchers also performed tests using several different tracers, including helium,
lithium bromide, and various dyes.  Tables 5 and 6 show the amounts and concentrations of selected dyes
and tracers used in research at the site in 1997. In order to tag construction, dust control, and drilling water,
researchers also used approximately 1.4 ft3 of helium in eight tracer tests and 15,000 ounces of lithium
bromide (diluted in over 4.6 million gallons of water).  Table 7 provides a side-by-side comparison of
analytical results characterizing ground water collected from a tracer test injection well and a drinking water
well at the Micca Mountain site. Figure 2 shows a schematic diagram of an injection well used for multi-
strata tracer studies.

             Table 5. 1997 Dye Usage, Yucca Mountain Site Characterization Project,
                                    Yucca Mountain,  Nevada
Dye
FD&C Blue #1
No. 8006 FD&C Yellow #6
FD&C Red #40
Sulfo rhodamine b
Lissamine FF
Amount Used (liters)
2.3522
0.13
2.2493
2.5718
0.118
Average Concentration (mg/1)
8,750
9,200
8,250
1,830
1,900
Source: USDOE, 1997a
   Table 6: 1997 Tracer Injection Analysis, Yucca Mountain Site Characterization Project, Yucca
                                       Mountain, Nevada
Tracer
LiBr (Lithium ion)
LiBr (Bromide ion)
PFBA
Fluorescent Microspheres
2,6-DFBA
Pyridone
Amount
Injected (kg)
14.6 (Li)
165.1 (Br)
12.12
0.0085
11.3505
3.018
Peak Concentration
(mg/1)
0.56
9.4
0.83
2.0 million/L
0.251
0.0437
Mass
Recovered (kg)
9.5 (Li)
115(Br)
10.24
0.0013
8.0
0.038
Percent Recovered
65
69
84
15
70
1.9
Source: USDOE, 1997b
   September 30, 1999
17

-------
       Table 7.1997 Semi-annual Ground Water Sampling Results, Yucca Mountain Site
                            Characterization Project, Nevada
Constituent
Total Dissolved Solids
Electrical Conductivity (• mo/cm)
Calcium
Magnesium
Sodium
Potassium
Sulfate
Chloride
Nitrate
Bicarbonate
Carbonate
Fluoride
Arsenic
Iron
Manganese
Copper
Zinc
Barium
Boron
pH (units)
Cadmium
Chromium
Lead
Mercury
Molybdenum
Nickel
Concentration mg/1 (except as noted)
Tracer Testing Injection Well
241
294
13
0.34
56
2.0
17
7.6
1.3
100
ND
1.7
ND
ND
ND
ND
ND
ND
0.14
8.04
ND
ND
ND
ND
NR
NR
Drinking Water Well
241
270
13
2.0
44
5.6
16
7.5
2.0
100
ND
1.6
ND
ND
ND
ND
ND
ND
0.14
7.62
ND
ND
ND
ND
ND
ND
September 30, 1999
18

-------
        Table 7.1997 Semi-annual Ground Water Sampling Results, Yucca Mountain Site
                         Characterization Project, Nevada (Continued)
Constituent
Selenium
Silver
Tungsten
Gross Alpha (pCi/L)
Gross Beta (pCi/L)
Silica
Lithium
Strontium
Bromide
Iodide
Pentafluorobenzoic Acid
2,6-Difluorobenzoic Acid
Fluorescent Microspheres
Pyridone
Concentration mg/1 (except as noted)
Tracer Testing Injection Well
ND
ND
ND
2.1±1.8
0.7±2.1
41
0.06
0.043
ND
ND
ND
ND
ND
ND
Drinking Water Well
ND
ND
ND
2.7±1.5
4.5±2.2
35
0.043
0.049
ND
ND
ND
ND
ND
ND
NR - Not Reported  ND - Not Detected
Source: USDOE, 1997b
  September 30, 1999
19

-------
   Figure 2. Schematic Diagram of Pneumatic Packed Tracer Injection Well for Geologic Strata
                              Tracer Studies at Yucca Mountain Site
       (Source: http://wwwymp.gov/about/science/e_sci/pneuma.htm) USDOE, No date.
       3.3    Potential and Documented Damage to USDWs

       The chemical quality of fluids released into experimental tracer study wells is not necessarily the best
indicator of the potential damage that these wells can have on USDWs.  The risk associated with
experimental wells is largely a function of the receiving ground water and aquifer characteristics as well as the
objective of the experimental project.

       In some cases, tracer study wells intentionally introduce a tracer into the ground water at a specific
concentration and location, knowingly exceeding drinking water standards.  This being the case, a direct
comparison of injectate quality to drinking water standards is useful, but does not tell the whole story about
the potential for experimental wells to endanger USDWs. It is also necessary to consider the potential
effects of experimental well operations by evaluating ground water monitoring data for these well systems.
In general, operators of experimental injection wells are required to collect ground water quality data from
monitoring wells situated in the vicinity of the injection well.  Monitoring is required to determine whether the
experimental well operation is having the desired effect and to determine  whether the operation is having any
effects beyond its zone of operation (e.g., the tracer is migrating beyond the  aquifer formation).
   September 30, 1999
20

-------
        Section 3.3.1 identifies the injectate constituents likely to exceed drinking water standards and
reviews the properties of these constituents that most influence risk (e.g., toxicity, persistence, and mobility in
ground water).  Section 3.3.2 then summarizes available ground water monitoring results and other
information on observed impacts associated with experimental well operations.

       Numerous boreholes intersecting many different geologic strata or levels have been drilled for tracer
studies at the Micca Mountain Site.  Tracer study injection wells use inflatable rubber bladders to separate
the different geologic segments ("packing them off"). These balloon-like devices allow DOE to study if and
how gases move through the various strata.  Tracer gases are injected into these boreholes and the
circulating gas pressure, found in each strata, is then measured to determine how much gas can be recovered
back from the rock.

        3.3.1   Injectate Constituent Properties

        The primary constituent properties of concern when assessing the potential for Class V wells to
adversely affect USDWs are toxicity, persistence, and mobility.  The toxicity of a constituent is the potential
of that contaminant to cause adverse health effects if consumed by humans. Appendix D to the Class V
Study provides information on the health effects associated with contaminants  found above drinking water
standards or health advisory limits in the injectate of experimental wells and other Class V wells.  As
discussed in Section 3.2.1, the contaminants that have been observed above MCLs and/or HALs in
experimental well injectate are chloride, strontium,  sulfates, uranium, molybdenum, and arsenic.

       Persistence is the ability of a chemical to remain unchanged in composition, chemical state, and
physical state over time. Appendix E presents published half-lives of common constituents in fluids released
in experimental wells and other Class V wells. All of the values reported in Appendix E are for ground
water.  Caution is advised in interpreting these values because ambient conditions have a significant impact
on the persistence of both inorganic and organic compounds.  Appendix E also provides a discussion of
mobility of certain constituents found in the injectate of experimental wells and other Class V wells.

        3.3.2   Observed Impacts

        Ground water monitoring data are not available for all of the experimental injection wells for which
injectate data and other permit data were reported.  Potential effects on ground water quality identified in the
survey conducted for this study include:

•      Migration of tracers from the study zone into drinking water aquifers; and
       Migration of contaminants (e.g., uranium, strontium) from reinjection of native contaminated ground
       water.

        The experimental tracer study well at the Naturita, Colorado site was the only well that did not meet
primary MCLs, secondary MCLs, and HALs.  The injectate for this tracer well exceeded MCLs for sulfates
and chloride,  and contained arsenic and molybdenum at levels greater than HALs. However, in this case,
   September 30, 1999                                                                          21

-------
the injectate was not being injected into an aquifer of drinking water quality.  In particular, the natural
concentrations of strontium and uranium in the receiving aquifer were higher than normal background levels.

       None of the state UIC programs documented any incidents of USDW contamination (i.e.,
exceedance of drinking water standards) from the operation of experimental tracer study wells.

       The majority of experimental tracer study wells reported by state and USEPA Regional UIC
programs are used to inject tracers (e.g., organic dyes, noble gases, short half-life radionuclides) into ground
water.  These tracers are used to determine the characteristics of the ground water. In tracer study well
experiments, these compounds are injected in low concentrations.  Therefore, negative ground water
impacts are unlikely.  As discussed in Attachment A, state UIC programs generally require that tracer wells
be permitted and operated so as not to affect ground water quality. Given this requirement, no incidents of
USDW contamination have been reported from the operation of experimental technology wells.

       3.4     Best Management Practices

       Best management practices (BMPs) for experimental tracer study wells are similar to the best
management practices for aquifer remediation wells (see \blume 16),  and include proper site characteristics,
design, construction,  maintenance, operation, monitoring, and closure. BMPs for tracer study wells are
primarily related to the concentration and characteristics of the tracer.  In general, tracers are injected in low
concentrations with either potable or native ground water.  Ideal tracers do not affect the flow regime or
experience significant chemical, biological, or physical reactions during the test(s) (Holmbeck-Pelham,
1998). Tracer injectate concentrations can be minimized by using tracers of unique isotopic signatures.
These signatures can allow the researcher to distinguish between natural and introduced compounds. In
some cases, environmentally benign tracer compounds such as sodium and potassium salts can be used as
tracers.  However, for other applications, tracers with more unique signatures are required. While stable
and radioactive isotopes fit this description, their use can raise concerns about residual radioactivity.  This
radioactivity can be minimized by using radioactive isotopes that have short half-lives.

       Another potential concern for tracer study wells is the use  of existing ground water as a tracer
carrier. Many tracer studies are conducted at aquifer remediation  sites where ground water is already
contaminated with metals,  organic compounds,  or other constituents.  The use of contaminated ground water
as a tracer carrier could potentially spread this contamination to other areas, if the tracer wells and
monitoring wells are not sited properly. However, the nature of the tracer study or the lack of potable water
may require the use contaminated ground water. Therefore, careful siting of both the injection and
monitoring wells will preclude any spreading  of contamination.  The potential for contamination can also be
reduced by minimizing the concentration and quantity of the injectate  required for the tracer study.
   September 30, 1999                                                                         22

-------
       3.5    Current Regulatory Requirements

       Several federal, state, and local programs exist that either directly manage or regulate experimental
wells, or impact them indirectly through broad based water pollution prevention initiatives.

       3.5.1  Federal Programs

       On the federal level, management and regulation of Class V experimental wells fall primarily under
the UIC program authorized by the Safe Drinking Water Act (SDWA), as discussed below. Some states
and localities have used these authorities, as well as their own authorities, to extend the controls in their areas
to address endemic concerns associated with experimental wells.  Because more than  97 percent of the
documented experimental wells are owned or operated by DOE, applicable DOE environmental control
programs are also summarized below.

       SDWA

       Class V wells are regulated under the authority of Part C of SDWA.  Congress enacted the SDWA
to ensure protection of the quality of drinking water in the United States,  and Part C specifically mandates
the regulation of underground injection of fluids through wells. USEPA has promulgated a series of UIC
regulations under this authority. USEPA directly implements these regulations for Class V wells in 19 states
or territories (Alaska, American Samoa, Arizona, California, Colorado, Hawaii, Indiana, Iowa, Kentucky,
Michigan, Minnesota, Montana, New York, Pennsylvania, South Dakota, Tennessee, Virginia, Virgin
Islands, and Washington, DC). USEPA also directly implements all Class V UIC programs on Tribal lands.
In all other states, which are called Primacy States, state agencies implement the Class V UIC program, with
primary enforcement responsibility.

       Experimental wells currently are not subject to any specific regulations tailored just for them, but
rather are subject to the UIC regulations that exist for all Class V wells.  Under 40 CFR 144.12(a), owners
or operators of all injection wells, including  experimental wells, are prohibited from engaging in any injection
activity that allows the movement of fluids containing any contaminant into USDWs, "if the presence of that
contaminant may cause a violation of any primary drinking water regulation ... or may otherwise adversely
affect the health of persons."

       Owners or operators of Class V wells are required to submit basic inventory information under 40
CFR 144.26. When the owner or operator  submits inventory information and is operating the well such that
a USDW is not endangered, the operation of the Class V well is authorized by rule. Moreover, under
section 144.27, USEPA may require owners or operators of any Class V well, in USEPA-administered
programs, to submit additional information deemed necessary to protect USDWs. Owners or operators
who fail to submit the information required under sections 144.26 and 144.27 are prohibited from using their
wells.

       Sections  144.12(c) and (d) prescribe mandatory and discretionary actions to be taken by the UIC
Program Director if a Class V well is not in compliance with section 144.12(a).  Specifically, the Director


   September 30, 1999                                                                        23

-------
must choose between requiring the injector to apply for an individual permit, ordering such action as closure
of the well to prevent endangerment, or taking an enforcement action. Because experimental wells (like
other kinds of Class V wells) are authorized by rule, they do not have to obtain a permit unless required to
do so by the UIC Program Director under 40 CFR 144.25. Authorization by rule terminates upon the
effective date of a permit issued or upon proper closure of the well.

        Separate from the UIC program, the SDWA Amendments of 1996 establish a requirement for
source water assessments.  USEPA published guidance describing how the states should carry out a source
water assessment program within the state's boundaries. The final guidance, entitled Source Water
Assessment and Programs Guidance (USEPA 816-R-97-009), was released in August 1997.

        States must conduct source water assessments which are comprised of three steps. First, a state
must delineate the boundaries of the assessment areas in the state from which one or more public drinking
water systems receive supplies of drinking water. In delineating these areas, states must use "all reasonably
available hydrogeologic information on the sources of the supply of drinking water in the state and the water
flow, recharge, and discharge and any other reliable information as the state deems necessary to adequately
determine such areas."  Second,  the state must identify contaminants of concern, and for those contaminants,
the state must inventory significant potential sources of contamination in delineated source water protection
areas.  Class V wells, including experimental wells, should be considered as part of this source inventory, if
present in  a given area.  Third, the state must "determine the susceptibility of the public water systems in the
delineated area to such contaminants." States should complete all of these steps by May 2003 according to
the final guidance2

       DOE Environmental Control Programs

        Approximately 99 percent of the experimental injection wells reported in the UIC survey
questionnaires are experimental tracer study wells being operated at DOE facilities as part of the its ongoing
aquifer remediation programs. A representative of the DOE Office of Science and Technology familiar with
the aquifer remediation program at the DOE Oak Ridge Reservation in Oak Ridge, Tennessee indicated that
she did not believe that the Department has established any standardized procedures for the construction
and operation of tracer study wells (Phillips, 1999). A representative of the USEPA National Risk
Management Research Laboratory who has worked with DOE on development of experimental tracer study
techniques for aquifer characterization indicated that experimental tracer study wells operated by DOE are
not subject to standardized design procedures but are designed on a site-specific basis (Parker, 1999).

        DOE is subject to federal and state environmental  regulations concerning the design and operation of
injection wells, including federal and state UIC regulations. DOE also has a system of Directives  (DOE
Orders) that have been developed by the Department to implement environmental protection programs.
DOE Order 5400.5, Radiation Protection of the Public and the Environment, establishes  standards and
requirements for operations of DOE and DOE contractors with respect to protection of members of the
public and the environment against undue risk from radiation. DOE Order 5400.1, General Environmental
       2 May 2003 is the deadline including an 18-month extension.

   September 30, 1999                                                                         24

-------
Protection Program, establishes environmental protection program requirements, authorities, and
responsibilities for DOE operations for assuring compliance with applicable federal, state, and local
environmental protection laws and regulations, executive orders, and internal department policies. Under
these and related DOE Orders, DOE is required to obtain operating permits for tracer study wells operated
at their facilities in states with UIC permit programs, and is required to comply with ground water protection
standards and other  environmental regulations related to construction and operation of underground
injection wells.

        3.5.2   State and Local Programs

        Six states — Colorado, Idaho, Nevada, South Carolina, Texas, and Washington — have
documented Class V experimental wells. Two of these states, Nevada and South Carolina, have more than
97 percent of the current documented well inventory. In addition, Illinois staff report that two experimental
wells have been recorded but are most likely no longer operating at this time.

        In Colorado, USEPA Region 8 directly implements the Class V UIC program. For the BOM Stope
Leaching Project Tracer Study and the  USGS Naturita Uranium Site Tracer Study conducted in that state,
USEPA Region 8 staff indicate that individual UIC permits were not required but that both projects were
rule authorized and subject to the general program requirements described above in Section 3.5.1. USEPA
Region  8 staff also indicate that, for the Naturita project, the rule authorization was valid for three years from
the date of issuance and the results of the tracer test had to be reported to USEPA. Both projects were also
required to comply with Colorado Department of Public Health and Environment Regulations (USEPA
Region  8, 1993).

        The other states listed above have primacy for the Class V UIC program and have established a
range of requirements for their programs. Specifically:

•       Idaho authorizes shallow injection wells (<18 feet deep) by rule, provided that inventory information
        is supplied and use of the well does not result in contamination of a USDW. Deep injection wells
        (>18 feet deep) must obtain an  individual permit. Both shallow and deep wells must satisfy
        operating requirements to ensure that no violation of the state's water quality standards for ground
        water occurs.

        Illinois has established rules for its Class V UIC program that are intended to be identical in
        substance to USEPA's rules in 40 CFR Part 144.  The  state applies inventory requirements and
        uses a permit-by-rule approach to ensure non-endangerment of USDWs. The state may require an
        individual permit to ensure no violation of drinking water requirements.

•       Nevada requires experimental wells to obtain individual permits, based on detailed information about
        the facility.

        South Carolina requires experimental wells to obtain individual permits, based on detailed
        information about the facility. South Carolina's operating requirements for experimental wells are


   September 30, 1999                                                                         25

-------
       identical to the requirements for Class n and m injection wells. Monitoring requirements are the
       same as those for Class in wells.

•      Texas authorizes Class V wells, including experimental wells, by rule. The state applies mandatory
       requirements and uses a permit-by-rule approach to ensure non-endangerment of USDWs.  In
       addition, the state applies specific construction standards for Class V wells.

•      Washington individually permits experimental wells.

4.     EXPERIMENTAL ATES SYSTEM WELLS

       An aquifer thermal energy storage (ATES) system stores thermal energy by injecting heated and/or
cooled water into an aquifer for use at a later time.  ATES system injectate (whether heated or cooled)
generally is returned to the same aquifer from which it was previously withdrawn; however, in some cases,
the injectate may have come from a different aquifer or from surface water.  The heated or cooled water
stored in the  aquifer can be reused (for heating or cooling) by pumping the water to the surface. Although
no operating ATES systems were identified in the survey responses as currently being active, experimental
ATES systems were recently operated in Minnesota and New "Vbrk (Marseille and Wicke, 1992, Hoyer,
et. al., 1994). ATES systems are considered to be experimental injection wells because they are intended to
test new injection technologies. These systems are therefore discussed in this volume of the report, and are
not discussed in other report volumes.

       4.1    Prevalence of Wells

       No UIC program reported any operating ATES system wells.  ATES system wells, however, were
recently operated in New "Vbrk and Minnesota.

       There may be considerable temporal variation in the experimental well inventory data
because, unlike some of the other Class V injection well categories, experimental wells have a limited
operating life. Operating permits or rule authorizations for experimental wells generally expire at the
conclusion of the experiment being conducted (e.g., when an experimental injection technology is
demonstrated as either viable or not viable). Therefore, ATES system wells may be  operated in the future,
although none were reported to be operating at present.

       4.2    Injectate Characteristics and Injection Practices

       Although no ATES system wells are currently known to be operating, their injectate characteristics
and injection practices are described here because they have been used recently and may be used  again in
the future. Because injectate data for ATES system wells were not available, Section 4.2.1  presents
general characteristics of ATES system injectate. Section 4.2.2 presents ATES system injection practices.
   September 30,  1999                                                                       26

-------
       4.2.1  Injectate Characteristics

       Injectate data for experimental ATES systems were not available, and therefore only a general
discussion of injectate characteristics is included in this section. Injectate for ATES systems is commonly
heated water, or in some cases cooled water, that is being returned to the same aquifer from which it was
withdrawn. In some cases, the water that is injected may come from a different aquifer or from a surface
water source. In addition, cleaning agents may be injected into ATES system wells during well operation
and maintenance activities to prevent plugging of the well due to scaling or other causes. The Minnesota
Franconia-Ironton-Galesville Experimental ATES System provides an illustrative example of this type of
well.  Based on the review of the literature, an ATES system was operated in a confined aquifer system in
St. Paul, Minnesota, referred to as the Franconia-Ironton-Galesville (F-I-G) aquifer (Hoyer, et. al., 1994).
The injectate was ground water that had been heated and softened.

       4.2.2  Well Characteristics and Operating Practices

       ATES injection wells are used to store thermal energy to supply process cooling, space cooling,
space heating, and ventilation air preheating; they may be used with or without heat pumps. Waste or by-
product energy, ambient air, and renewable energy (e.g., solar energy) are often used as energy sources for
ATES systems (Morofsky  1997).

       An ATES system is composed of one or more pairs of fairly conventional water supply wells drilled
into an aquifer (Hall and Raymond, 1992).  The well spacing is chosen to minimize interference and thermal
short-circuiting during operation, which is normally seasonal. ATES systems are designed to maximize the
amount of cold or heat stored in each cycle of ground water withdrawal and injection (Mirza, 1994). During
the operation, ground water is withdrawn from one well, heated or chilled in a heat exchanger, and then
returned for storage in the same aquifer through a second well.  The stored thermal energy is recovered
when the second well is pumped and the hot or cold water is again circulated through a heat exchanger and
then returned to the aquifer through the first well.  Different system types may be selected based on local
geology, geography, climate conditions, and general applications.  ATES systems have been classified into
four main types:

       1.     Storage of warm water;
       2.     Storage combined with process cooling;
       3.     Storage for combined space cooling and heating; and
       4.     High-temperature ATES systems.

       For the first type, in the summer, warm surface water is pumped through a heat exchanger to heat
ground water that is pumped from a cool part of the aquifer. The heated water is then  stored in a warm part
of the aquifer; in the winter, the water is withdrawn and used as a source of energy to a heat pump system.
The second and third types are similar and used for industrial process cooling and space heating and cooling.
The third type, however, differs in that the systems are designed for optimal space cooling while space
heating is complemented by the use of heat pumps.  Typical users of ATES systems are commercial building
owners and district heating networks (Andersson and  Sellberg, 1992).  Approximately 83% of 55 systems


   September 30,  1999                                                                        27

-------
reviewed (from Canada, Germany, The Netherlands, and Sweden) were for commercial building
applications, 13% for process cooling, and 4% for residential applications (Chant and Morofsky, 1992, Hall
and Raymond, 1992).

       ATES systems can potentially be used for seasonal and short-term energy storage at temperatures
ranging from 2°C to more than 100°C. In Sweden, several low-temperature systems (<25°C) have
operated since before 1990.  These systems also generally involve the use of heat pumps in combination
with the seasonal storage (Andersson and Sellberg, 1992).  Many systems have storage temperatures in the
range of 12 to 40°C, while there are fewer - one study found only six - high-temperature systems (greater
than 85°C). In 1992, high temperature systems were considered experimental (Jenne, et. al., 1992).  One
experimental high-temperature system was constructed to study scaling caused by over saturation
(Andersson and Sellberg, 1992).

       Potentially suitable aquifers for ATES systems are widely available throughout the U.S. The
capacity of an aquifer limits the flow rate of an ATES system.  The effective porosity of the aquifer affects
the volume of aquifer required to store a volume of heated or  chilled water.  This consequently affects the
size of an ATES well field required to store a specified quantity of energy (Hall and Raymond, 1992).
Maximum flow rates range from 30 to 1,000 m3/hour (Andersson and Sellberg,  1992). ATES system wells
may be operated in either confined or unconfmed aquifers. Operation in a confined aquifer would inhibit
heated water from migrating out of the formation.

       The configuration of ATES systems also varies widely depending upon the application. Although
information on ATES systems in the U.S. is limited, information characterizing these systems in Europe is
believed to be representative of systems in the U.S. For example, in Switzerland, one experimental ATES
system has a large diameter central well (2.2 meters), from which two networks of six horizontal drains (0.2-
meter diameter, 25-meter length) were driven into the soil at the level of two sandy aquifers (depths of 7 and
24 meters). The storage volume is 100,000 m3 with a flow rate of 5-20 mVhour (Jollien, et. al., 1992).
This system is illustrated in Figure 3.  Schematic diagrams of three other experimental ATES systems,
recently operated in Europe, are included in Figures 4 through 6.
   September 30,  1999                                                                       28

-------
             Figure 3. Schematic Diagram of Dorigny, Switzerland ATES System


         ftst stoge 0962 • 19S5)
"It *lI it
         Second Stogei 0085 -
                         PRESENT 1
                                                                     Om

                                                                    (* m
                                                                     26m
Source:  Jollien, et. al, 1992
  September 30, 1999
                                      29

-------
              Figure 4. Schematic Diagram of Stuttgart, Germany ATES System
           Watt**


            Siza
            am)

            Stzt
            pont
Source: Adinolfi and Ruck, 1992
  September 30, 1999
30

-------
                 Figure 5. Schematic Diagram of Impounded ATES System at
                             University of Stuttgart, Germany
                                       A » It.* m
                                    or Ic1( 0Q cm)
                                      OiBtn «t
Source: Adinolfi and Ruck, 1992
  September 30, 1999
31

-------
        Figure 6. Schematic Diagram of Combined Process ATES System, Malmo, Sweden
                                   -0	1
Source: Andersson and Selberg, 1992
       Separately, in New York, an experimental ATES system (which is believed to no longer be
operating) consisted of six wells, each 55 meters in depth, with a 0.305-meter diameter steel bushing fitted
with a 15.2-meter long screen, of 0.2-meter diameter. The screen is surrounded by a 0.46-meter diameter
fine gravel envelope that extends 6.1 meters above the screen for a total height of 21.3 meters.  The casing
above the gravel pack is enclosed in cement grout. The well pump is within the casing above the screen and
within the water table at a sufficient distance to allow for draw down. The 25-millimeter clearance around
the pump on all sides of the well casing allows for recharge.  The wells are located in glacial outwash sand
and gravel sediments (manetto gravel).  The ground water table is 12.2 meters below surface grade
(Marseille and Wilke, 1992).

       Finally, in Minnesota, one recent field-test facility of an ATES project was conducted in the
Franconia-Ironton-Galesville (F-I-G) confined aquifer in St. Paul, Minnesota. Researchers assessed the
feasibility of designing, constructing, and operating the ATES  system in a confined aquifer at temperatures as
high as 150°C. The storage and source wells were spaced 225 meters apart (Hoyer, et. al., 1994).
   September 30, 1999
32

-------
       4.3     Potential and Documented Damage to USDWs

       The chemical quality of fluids released into ATES system wells is not necessarily the best indicator of
the potential for these wells to threaten USDWs, because the risk associated with experimental wells is
largely a function of the receiving ground water and aquifer characteristics as well as the objective of the
experimental project. For example, injection of heated and softened ground water into the experimental
ATES facility located in Minnesota lowered ground water temperature, raised ground water pH, and
resulted in the mobilization of silica into the ground water from the native quartz deposits in the receiving
formation.  Although data are not available for other metals, it is possible that changes to the chemistry of the
ground water resulting from injection of heated and softened water or other treated water could mobilize
toxic metals (e.g., chromium, arsenic) if they are also present in the formation.

       This being the case, a direct comparison of injectate quality to drinking water standards is useful, but
does not tell the whole story about  the potential for experimental wells to endanger USDWs. It is also
necessary to consider the potential  effects of ATES system well operations by evaluating ground water
monitoring data for these systems.  In general, operators of experimental injection wells are required to
collect ground water quality data from monitoring wells situated in the vicinity of the injection well.
Monitoring is required to  determine whether the experimental well operation is having the desired  effect and
to determine whether the  operation is having any effects beyond its zone of operation (e.g., is heated water
injected into an ATES system aquifer formation migrating beyond the formation).

       Section 4.3.1 identifies the  injectate constituents likely to exceed drinking water standards.  Section
4.3.2 then summarizes available ground water monitoring results and other information on observed impacts
associated with experimental well operations.

       4.3.1   Injectate Constituent Properties

       The constituents that may exceed MCLs and HALs in ATES system well injectate include chlorine,
arsenic, and chromium. Biological  constituents (represented by total coliforms) may also be present in some
ATES system wells. In addition, although not present in the injectate itself, ground water monitoring data for
experimental injection wells indicate that trihalomethanes may be created in the aquifer through chemical or
physical reaction between the injectate and the ground water or receiving formation.

       Appendix D to the Class V Study describes the critical or adverse lexicological effects noted in the
studies that served as the  basis for the MCLs or HALs for these constituents. Appendix E to the study
presents data on the persistence and mobility of these and other constituents in ground water.
   September 30, 1999                                                                          33

-------
       4.3.2   Observed Impacts

       Ground water monitoring data are not available for ATES system experimental injection wells.
However, several potential effects on ground water quality were identified as a result of the survey
conducted for this study, including production of trihalomethanes in ground water from injection of treated
(chlorinated) water into aquifers; and mobilization of minerals from receiving formations into ground water
from injection into aquifers.

       Although experimental ATES system well operations were not reported to result in contamination of
a USDW to concentrations greater than drinking water standards, elevated concentrations in ground water
above background concentrations resulting from physical or chemical reaction of the injectate with the
ground water or ground water formation were notable for some experimental injection wells. Potential
impacts that may result directly from injectate characteristics or from physical or chemical reactions are
discussed further in Section 4.4.2.

       Injectate used for ATES systems (e.g., water used for heating or cooling systems) may not meet
primary and secondary drinking water standards.  Operation of ATES systems may also result in changes in
ground water temperature and geochemistry, and water treatment chemicals used in these operations may
migrate outside the ATES system aquifer. Literature sources indicate that the experimental ATES system
formerly operated in Minnesota affected the characteristics of the underlying aquifer.

       In general, ATES operations induce geochemical changes to native waters through the introduction
of non-native waters or heat (Holm, et. al, 1987).  Some of the geochemical changes that occur include
precipitation-dissolution reactions, ion exchange, and mixing. All of these types of reactions may occur to
different extents and at different times during ATES operation.  In the case of the experimental F-I-G
aquifer ATES system in St. Paul, Minnesota, the ATES operations caused the character of the geochemistry
of the native ground water to change from a calcium-magnesium-bicarbonate water system near saturation
with calcite, aragonite and dolomite, to a sodium-bicarbonate water system. The ATES system testing also
caused changes in ground water pH, alkalinity, dissolved silica, and most major ion concentrations.  Ground
water sampling data from the ATES operations on the F-I-G aquifer indicate that the ATES system raised
the native water temperature; slightly lowered the pH; and slightly increased the concentration of chloride,
fluoride, and silica above background levels (Hoyer, et. al., 1994).

       In addition to the direct effects of geochemical and heat changes (within the aquifer and its close
surroundings), there are other potential risks including (Andersson and Sellberg, 1992):

       Leakage of toxic substances like glycol, brine, etc.;
       Emission of CFC gases (see discussion below on methane);
•      Growth of pathogenic bacteria; and
•      Change of water composition in the aquifer due to chemical treatment.

       Some aquifer systems have  had high concentrations of dissolved gases such as methane while others
have had no major chemical contamination (Chant and Morofsky 1992). Reaction of methane with HC1


  September 30, 1999                                                                          34

-------
used as a water treatment chemical could result in the production of CFCs. Scaling and clogging were cited
as the biggest operational problem with ATES systems; the injection of HC1 prevented scaling but increased
corrosion and potential environmental impacts. The changes in aquifer chemistry included pH and hardness
(over saturation for calcium carbonate) (Jollien, et. al, 1992).

       4.4     Best Management Practices

       Research suggests certain characteristics are key to successful performance of ATES wells.  This
research generally defines successful performance in terms of energy storage and system operation,  and not
necessarily in terms of ground water quality. Best management practices begin with design of the system and
continue through construction and installation, characterization of the aquifer, and operation and maintenance
of the well.

       Proper design of wells includes attention to the entire well field and its relationship to the storage
aquifer. In addition, the water well design for the ATES facility requires that the energy management plan of
the facility be known. Poor design and installation of a number of ATES wells has led to poor performance.
Factors responsible for poor efficiency and specific yield include inadequate recognition of geochemical and
biologically induced degradation with time and temperature changes, use of improper water well  design,
incorrect siting, insufficient quality control during well construction, and not understanding the demands
placed on the well during its service. ATES operation requires wells and drains that are designed to
withstand seasonal changes in flow direction, accommodate large  changes in temperature on a cyclical basis,
and operate with little maintenance.

       Aquifer characterization, including site-specific investigations, is a critical step for well design.  The
characterization involves understanding the regional and local geology and hydrogeology, including analysis
of all operating water wells within a 2 to 3 mile radius of the ATES facility. Test wells are screened and
developed until the suspended solids in the discharge water are less than 1 ppm. A test well with more than
1 ppm of sediment during sustained pumping indicates either that it is not properly designed, installed or
developed, or that the aquifer has features that have not been taken into  consideration. Test drilling  and
pumping tests also yield water quality information and indicate whether or not dissolved gases may be
present under the confining aquifer pressure. The presence of gases can  later lead to problems in installation
and pollution from gases escaping into formations intersected by the well bore.  For well drilling, mud can
invade the fine pores of the aquifer formation. Proper well development ensures that all the mud that has
migrated into the aquifer formation is pulled back out of the aquifer zone immediately adjacent to the gravel
pack. If not, wells will eventually clog within a few years after commissioning (Mirza,  1994).

       The most significant problems affecting the operation of experimental ATES systems are caused by
scaling, clogging, and corrosion. Microbes play a crucial role  in these processes and are relevant to water
quality (Seppaenen,  1994). However, most of the hydrochemically related clogging and corrosion problems
in ATES systems can be predicted and prevented by  proper design, construction, operation (including water
treatment), and performing complete and careful pre-investigation.  Scaling of heat exchangers and clogging
of wells, gravel pack, and adjacent aquifer(s) caused by chemical  precipitates has frequently occurred in
ATES  systems. The precipitation of carbonates has especially occurred  in systems operating above 85°C


  September 30, 1999                                                                           35

-------
and iron and manganese oxides in systems operating below 40°C (Jenne, et. al., 1992). The content of
phosphonates or dissolved organic matter in the ground water serves as natural inhibitors for growing
carbonate crystals (Andersson and Sellberg, 1992). Conventional treatments for scaling utilize hydrochloric
acid, sodium hydroxide, or ion exchange (with a large consumption of regeneration chemicals) (Koch and
Ruck,  1992).  To avoid problems associated with conventional water treatment, chemicals and processes
are used to prevent scaling (i.e., mineral deposits inside pipes); the use of small amounts of carbon dioxide
has been found to be a preferable treatment alternative (Koch and Ruck, 1992).

        Clogging by iron bacteria slime is a potential risk mainly in low-temperature systems and in waters
with an iron concentration of at least 1  mg/1. Major bacterial growth is also a risk with redox potential (Eh)
values between 200 and 400 mV and pH values between 5.5-7.5.  Corrosion usually occurs in slightly
acidic water and with total dissolved solids greater than approximately 1,000 mg/1 (Driscoll, 1986 as cited in
Jenne, et. al., 1992).

        At the ATES facility in St. Paul, Minnesota, the water injected into the aquifer was treated by an
ion-exchange water softener to decrease calcium carbonate precipitation and scaling within the ATES
system. Previous operation of the system with a calcium carbonate precipitator filter protected the aquifer
and injection well from scaling and clogging problems, but scale build up required the heat exchangers to be
shut down for eight hours at a time so that the filters could be replaced (Hoyer, et. al.,  1994).

        The principal technical problems with warm surface water storage systems has been biofouling of the
surface water heat exchanger, clogging of injection wells,  and clogging of recovery wells during production.
The biofouling problem has been solved through use of a specially designed air bubble filter in front of the
surface water open-hole inlet.  Frequent cleaning with acid has been used to remove iron precipitation in the
tubes and the heat exchanger.  In one system, the source of the iron precipitation was considered to be from
the mixing of lake water containing elevated iron with oxidized aquifer water (relatively free of iron).  The
oxidized water oxidized the iron rich water when mixed in one of the wells, which caused a delayed
precipitation reaction to occur in tubes  and fittings. This problem was proposed to be resolved with an in
situ oxidation of the dissolved iron (Andersson and Sellberg, 1992).

        ATES well operations are also frequently hindered by the presence of a specific bacteria species,
Legionella.  Factors to control the survival and propagation of Legionella include:

        Maintaining pH and alkalinity  of the ground water below 5.5 or above 8.1 (tolerance range).
•       Preventing scaling and corrosion (of cooling towers) with the addition of organic phosphorous
        compounds and corrosion inhibitors such as zinc and chromate.
        Adding commercially available biodispersants to ensure Legionella associated with biofilms are
        exposed to disinfectant and high alkalinity conditions.
•       Reducing concentrations of metals, such as manganese and zinc, to levels that do not support the
        growth ofLegionella.  Low  levels of certain metals (such as iron, zinc, and potassium) enhance
        growth ofLegionella.
•       Maintaining temperatures of water systems below 5°C or above 65°C. Legionella have been
        isolated at temperatures between 5.7 and 63°C.


   September 30, 1999                                                                         36

-------
       Selecting biocides detrimental to both Legionella and the specific microflora found in association
       with this microorganism.
•      Keeping the environment aerobic. Legionella have been isolated at dissolved oxygen content
       between 0.3 to 9 mg/1 (Hicks and Stewart, 1988 as cited in Seppaenen, 1994).
       Using treatment chemicals responsibly and only in the amounts and frequencies necessary to control
       bacterial growth, biofouling, and other system operating parameters.

       4.5    Current Regulatory Requirements

       4.5.1   Federal Programs

       ATES system wells are covered by the UIC regulations discussed in Section 3.5.1 of this volume.

       4.5.2   State and Local Programs

       No UIC program reported any operating ATES wells.  Therefore no state regulatory requirements
currently apply.
   September 30,  1999                                                                        37

-------
                                        ATTACHMENT A
                       STATE AND LOCAL PROGRAM DESCRIPTIONS

       This attachment does not describe every state's program requirements; instead it focuses on the six
states where experimental tracer study wells are known to exist: Colorado, Idaho, Nevada, South Carolina,
Texas, and Washington. Altogether, these six states have a total of 396 documented experimental tracer
study wells.  The program in Illinois is also described because that state reports two experimental wells that
are most likely no longer operating.

Colorado

       Colorado is a Direct Implementation state.  However, the state engineer issues permits to construct
wells.  The Water Well Construction Rules (2 Colorado Code 402-2) (CCR)  apply to well construction
contractors and drillers and to the construction of water wells, test holes, dewatering wells, monitoring and
observation wells, and well plugging and sealing (abandonment). The rule specifies that excavations that do
not penetrate through a confining layer between aquifers recognized by the state engineer may be designed,
constructed,  used, and plugged and sealed by authorized individuals, as specified in the rule, who are not a
licensed well construction contractor.  Wells constructed for sampling, measuring and test pumping for
scientific, engineering, and regulatory purposes that do not penetrate a confining layer may be constructed by
an authorized individual.

Idaho

       Idaho is a Primacy state and has promulgated regulations for the underground injection control
program in the Idaho Administrative Code (IDAPA), Title 3,  Chapter 3.  Deep injection wells are  defined as
more than 18 feet in vertical depth below the land surface (37.03.03.010.11 IDAPA). Wells are further
classified, with Class V Subclass 5X25 defined as experimental technology wells (37.03.03.025.Ol.z
IDAPA).

       Permitting

       Construction and use of shallow injection wells is authorized by rule, provided that inventory
information is provided and use of the well does not result in unreasonable contamination of a drinking water
source or cause a violation of water quality standards that would affect a beneficial use (37.03.025.03.d.
IDAPA).  Construction and use of Class V deep injection wells  may be authorized by permit
(37.03.03.025.03.c IDAPA).  The regulations outline detailed specifications for the information that must be
supplied in a permit application (37.03.03.035 IDAPA).

       Operating Requirements

       Standards for the quality of injected fluids and criteria for location and use are established for rule-
authorized wells, as well as for wells requiring permits. The rules are based on the premise that if the
injected fluids meet MCLs for drinking water for physical, chemical, and radiological contaminants at the


   September 30,  1999                                                                        38

-------
wellhead, and if ground water produced from adjacent points of diversion for beneficial use meets the water
quality standards found in Idaho's "Water Quality Standards and Wastewater Treatment Requirements,"
16.01.02 IDAPA, administered by the Idaho Department of Health and Welfare, the aquifer will be
protected from unreasonable contamination. The state may, when it is deemed necessary, require specific
injection wells to be constructed and operated in compliance with additional requirements (37.03.03.050.01
IDAPA (Rule 50)). Rule-authorized wells "shall conform to the drinking water standards at the point of
injection and not cause any water quality standards to be violated at the point of beneficial use"
(37.03.03.050.04.d IDAPA).

       Monitoring, recordkeeping,  and reporting may be required if the state finds that the well may
adversely affect a drinking water source or is injecting a contaminant that could have an unacceptable effect
upon the quality of the ground waters of the state (37.03.03.055 IDAPA (Rule 55)). The permit for the
BSU Department of Geology tracer study well also prohibits the injection well operation from degrading
ground water or harming "beneficial uses" of ground water, and requires that Idaho water quality standards
not be exceeded.

       Plugging and Abandonment

       The Idaho Department of Water Resources (IDWR) has prepared "General Guidelines for
Abandonment of Injection Wells," which are not included in the regulatory requirements. IDWR expects to
approve the final abandonment procedure for each well. The General Guidelines recommend the following:

•      Pull casing, if possible. If casing is not pulled, cut casing a minimum of two feet below land surface;
•      Measure the total depth of the well;
       Perforate the  casing if is left in place. Neat cement with up to 5% bentonite can  be pressure-grouted
       to fill the hole. As an  alternative, when the casing is not pulled, coarse bentonite chips or pellets may
       be used to fill the hole. If the well extends into the aquifer, the chips or pellets must be run over a
       screen to prevent any  dust from entering the hole.  No dust is allowed to enter the bore hole because
       of the potential for bridging. Perforation of the casing is not required for this alternative;
       If well extends into the aquifer, a clean pit-run gravel or road mix may be used to fill bore up to ten
       feet below top of saturated zone or ten feet below the bottom of casing, whichever is deeper, and
       cement grout or bentonite clay used to surface. The use of gravel may not be allowed if the lithology
       is undetermined or unsuitable;
       Place a cement cap at top of the casing if it is not pulled, with a minimum of two feet of soil overlying
       filled hole/cap; and
•      Abandonment of well must be witnessed by IDWR representative.
   September 30, 1999                                                                          39

-------
       Financial Responsibility

       No financial responsibility requirement exists for rule-authorized wells  Permitted wells are required
by the permit rule to demonstrate financial responsibility through a performance bond or other appropriate
means to abandon the injection well according to the conditions of the permit (37.03.03.35.03.6 IDAPA).

Illinois

       Illinois is a Primacy state. The Illinois Environmental Protection Agency (IUSEPA), Bureau of Land
has promulgated rules establishing a Class V UIC program in 35 Illinois Administrative Code (IAC) 704 that
are intended to be identical in substance to USEPA rules in 40 CFR 144.

       Permitting

       Any underground injection, except into a well authorized by permit or rule, is prohibited.  The
construction of any well required to have a permit is prohibited until the permit has been issued (704.12.
IAC). Injection into Class V wells is authorized by rule until requirements under future regulations become
applicable (704.146 IAC).  Under the state's rules, basic information must be submitted, including the
activities to be conducted, location of the facility, principal activities, operator information, list of other
permits, topographic map of the facility, when required by the IUSEPA (702.123 IAC).  Wells used in
experimental technologies are required to submit the following information:

•      Location of each well;
•      Date of completion of each well;
•      Identification and depth of the formation(s) into which each well is injecting;
       Depth of each well;
•      Casing and cementing record, tubing size, and depth of packer;
•      Nature of the injected fluids;
       Average and maximum injection pressure at the wellhead;
       Average and maximum injection rate;
       Date of last mechanical integrity test, if any (704.148(b) IAC).

       Operating Requirements

       Owners or operators of wells authorized by rule must submit inventory information (704.148 IAC).
In addition, IUSEPA may require submission of other information deemed necessary by IUSEPA (704.149
IAC). This may include information about the performance of ground water monitoring, analysis of injected
fluids, and description of the geologic strata through which and into which injection is taking place.

       If at any time the IUSEPA learns that a Class V will may cause a violation of primary drinking water
regulations under 40 CFR 142, it will require the injector to obtain an individual permit, issue a permit that
requires the injector to take such action, including closure of the well, as may be necessary to prevent the
   September 30, 1999                                                                        40

-------
violation, or take enforcement action.  If a Class V well may be otherwise adversely affecting the health of
persons, the IUSEPA may prescribed such actions as may be necessary to prevent the adverse effect.

       Mechanical Integrity Testing

       If the IUSEPA determines that a well lacks mechanical integrity, it may order immediate cessation of
injection (704.142(f) IAC). However, the regulations do not establish a specific requirement for mechanical
integrity testing for Class V wells A permit for a Class V well may include requirements for demonstration of
mechanical integrity (704.190 IAC).

Nevada

       Nevada is a Primacy state in which the Division of Environmental Protection (DEP) administers the
UIC program. The statute specifically defines injection wells used in experimental technologies as Class V
wells (445A.849.16 NRS).

       Nevada Revised Statutes (NRS) §§ 445A.300 - 445A.730 and regulations under the Nevada
Administrative Code (NAC) §§ 445A.810 - 445A.925  establish the state's basic underground injection
control program.  The injection of fluids through a well into any waters of the state, including underground
waters, is prohibited without a permit issued by the DEP  (445A.465 NRS), although the statute allows
both general and individual permits (445A.475 NRS and 445A.480 NRS).  Furthermore, injection of a fluid
that degrades the physical, chemical, or biological quality of the aquifer into which it is injected is prohibited,
unless the DEP exempts the aquifer and the federal USEPA does not disapprove the exemption within 45
days after notice of it (445 A. 850 NRS).

       Regulations, particularly Chapter 445 A NAC, "Underground Injection Control," define and
elaborate these statutory requirements. First, they provide that any federal,  state, county, or municipal law
or regulation that provides greater protection to the public welfare,  safety, health, and to the ground water
prevails within the jurisdiction of that governmental entity over the  Chapter 445 A requirements (445 A. 843
NAC).

       Permitting

       The UIC regulations specify detailed information that must be provided in support of permit
applications, including proposed well location, description of geology, construction plans, proposed
operating data on rates and pressures of injection, analysis  of injectate, analysis of fluid in the receiving
formation, proposed injection procedures, and corrective  action plan (445A.867 NAC).  The DEP may
modify the permit application information required for a Class V well.
   September 30, 1999                                                                         41

-------
       Siting and Construction

       The state specifies, among other siting  requirements, that the well must be sited in such a way that it
injects into a formation that is separated from any USDW by a confining zone that is free of known open
faults or fractures within the area of review. It must be cased from the finished surface to the top of the zone
for injection and cemented to prevent movement of fluids into or between USDWs (445A.908 NAC).

       Operating Requirements

       Monitoring frequency for injection pressure, pressure of the annular space, rate of flow, and volume
of injected fluid is specified by the permit for Class V wells.  Analysis of injected fluid must be conducted
with sufficient frequency to yield representative data. Mechanical integrity testing is required once 5 years,
by a specified method (445A.913.5 NAC and 445A.916 - 445A.920 NAC). For the YMSCP site, the
concentration of injected chemicals "will not result in the injected water exceeding state or federal drinking
water standards or in degradation of waters of the state" according to officials at Nevada's Bureau of Water
Pollution Control (Land, 1997).

       Plugging and Abandonment

       A plugging and abandonment plan and cost estimate must be prepared for each well, and reviewed
annually.  Before abandonment, a well must be plugged with cement in a manner that will not allow the
movement of fluids into or between USDWs (445A.923 NAC).

       Financial Responsibility

       Class V wells may be required to provide a bond in favor of the state either equal to the estimated
cost of plugging and abandonment of each well or, if approved by DEP, a sum not less than $50,000 to
cover all injection wells of the permit applicant in the state (445 A. 871 NAC). However, if adequate proof of
financial responsibility is presented, the bonding requirements may  be waived or reduced.

South Carolina

       South Carolina is a Primacy  state.  The state's underground injection control program is
implemented by the Department of Health and Environmental Control (DHEC). The UIC regulations, found
in Chapter 61 of the state regulations (SCR), divide Class V wells into two groups, with experimental wells,
defined as "injection wells used in experimental technologies," found in group (A) ((R61-87.10E.(l)(g)).
The same requirements apply to experimental wells as are applied to other Class V(A) wells.
   September 30,  1999                                                                       42

-------
       Permitting

       Experimental wells, as Class V(A) wells, are prohibited except as authorized by permit (R61-
87.10.E.(2)).  The permit application must include a description of the activities to be conducted, the name,
address, and location of the facility, the names and other information pertaining to the owner and operator, a
description of the business, drawings of the surface and subsurface construction of the well, and proposed
operating data, including average and maximum daily rate and volume of fluid to be injected, average and
maximum injection pressure, and source and an analysis of the chemical, physical, biological, and
radiological characteristics of the injected fluid (R61-87.13.G(2)).  The movement of fluids containing
wastes or contaminants into USDWs as a result of injection is prohibited if the waste or contaminant may
cause a violation of any drinking water standard or otherwise adversely affect the health of persons (R61-
87.5).

       Siting and Construction

       Siting and operating criteria and standards for Class V(A) wells require logs and tests, which will be
specified by DHEC in the permit, to identify and describe USDWs and the injection formation.
Construction standards are the same as those applied to drinking water wells.

       Injection may not commence until construction is complete, the permittee has submitted notice of
completion to DHEC, and DHEC has inspected the well and found it in compliance
(R61-87.13U).

       Operating Requirements

       DHEC will establish maximum injection volumes and pressures and such other permit conditions as
necessary to assure that fractures are not initiated in the confining  zone adjacent to a USDW and to assure
compliance with operating requirements (R61-87.13 V). Operating requirements for Class V(A) wells are
not distinguished in the state regulations from operating standards for Class n and HI wells (R61-87.14).
Injection pressure at the wellhead may not exceed a maximum calculated value to ensure that injection does
not initiate new fracturing or propagate existing fractures in the confining zone adjacent to the USDW.

       Monitoring requirements will be specified in the permit.  Monitoring requirements for Class V(A)
wells are the same as those  for Class m wells, and may include installation of monitoring wells in the
injection zone and adjacent zones as necessary to detect the dispersion and migration of injection fluids
within and from the injection zone.  Monitoring of the fluid levels and water quality in the injection and
monitor wells at specified intervals and submission of monitoring results will be specified in the permit.
However, reporting of monitoring results to DHEC is required at least quarterly (R61-87.14.G and 1(1)).
   September 30, 1999                                                                         43

-------
       Mechanical Integrity

       Prior to granting approval for operation, DHEC will require a satisfactory demonstration of
mechanical integrity. Tests will be performed at least every 5 years (R61-87.14.G).

       Plugging and Abandonment

       A plugging and abandonment plan must be prepared and approved by DHEC (R61-87.12.B and
.15).

Texas

       Texas is a Primacy state.  The Injection Well Act (Chapter 27 of the Texas Water Code) and Title 3
of the Natural Resources Code provide statutory authority for the underground injection control program.
Regulations establishing the underground injection control program are found in Title 30, Chapter 331 of the
Texas Administrative Code (TAG).

       Permitting

       Underground injection is prohibited, unless authorized by permit or rule.  (331.7 TAG) By rule,
injection into a Class V well is authorized, although the Texas Natural Resources Control Commission
(TNRCC) may require the owner or operator of a well authorized by rule to apply for and obtain an
injection well permit (331.9 TAG). No permit or authorization by rule is allowed where an injection well
causes or allows the movement of fluid that would result in the pollution of a USDW. A permit or
authorization by rule must include terms and conditions reasonably necessary to protect fresh water from
pollution (331.5 TAG).  Experimental wells are not specifically identified in the rules as Class V wells, but
the category is not limited to the well types specified in the rules (331.11 (a)(4) TAG).

       Siting and Construction

       All Class V wells are required to be completed in accordance with explicit specifications in the rules,
unless otherwise authorized by the TNRCC.  These specifications are:

•      A form provided either by the Water Well Drillers Board or the TNRCC must be completed.
•      The  annular space between the borehole and the casing must be filled from ground level to a depth
       of not less than 10 feet below the land surface or well head with cement slurry.  Special requirements
       are imposed in areas of shallow unconfmed ground water aquifers and in areas of confined ground
       water aquifers with artesian head.
•      In all wells where plastic casing is used, a concrete slab or sealing block must be placed above the
       cement slurry around the well at the ground surface; and the rules include additional specifications
       concerning the slab.
       In wells where steel casing is used, a slab or block will be required above the cement slurry except
       when a pitless adaptor is used, and the rules contain additional requirements concerning the adaptor.


  September 30,  1999                                                                        44

-------
       All wells must be completed so that aquifers or zones containing waters that differ significantly in
       chemical quality are not allowed to commingle through the borehole-casing annulus or the gravel
       pack and cause  degradation of any aquifer zone.
•      The well casing must be capped or completed in a manner that will prevent pollutants from entering
       the well.
       When undesirable water is encountered in a Class V well, the undesirable water must be sealed off
       and confined to the zone(s) of origin (331.132 TAG).

       Operating Requirements

       None specified. Chapter 331, Subpart H, " Standards for Class V Wells" addresses only
construction and closure standards (331.131 to 331.133 TAG).

       Mechanical Integrity Testing

       Injection may be prohibited for Class V wells that lack mechanical integrity. The TNRCC may
require a demonstration of mechanical integrity at any time if there is reason to believe mechanical integrity is
lacking. The TNRCC may allow plugging of the well or require the permittee to perform additional
construction, operation,  monitoring, reporting, and corrective actions which are necessary to prevent the
movement of fluid into or between a USDW caused by the lack of mechanical integrity.   Injection may
resume on written notification from the TNRCC that mechanical integrity has been demonstrated (331.4
TAC).

       Plugging and Abandonment

       Plugging and abandonment of a well authorized by rule is required to be accomplished in accordance
with §331.46 TAC (331.9 TAC). In addition, closure standards specific to Class V wells provide that
closure is to be accomplished by removing all of the removable casing and filling the entire well  with cement
to land surface.  Alternatively, if the use of the well to be permanently discontinued, and if the well does not
contain undesirable water, the well may be filled with fine sand, clay, or heavy mud followed by a cement
plug extending from the land  surface to a depth of not less than 10 feet. If the use of a well that does contain
undesirable water
is to be permanently discontinued, either the zone(s) containing undesirable water or the fresh water zone(s)
must be isolated with cement plugs and the remainder of the well bore filled with  sand, clay, or heavy mud to
form a base for a cement plug extending from the land surface to a depth of not less than 10 feet (331.133
TAC).

       Financial Responsibility

       Chapter 27 of the Texas Water Code,  "Injection Wells," enacts financial responsibility  requirements
for persons to whom an injection well permit is issued.  A performance bond or other form of financial
security may be required to ensure that an abandoned well is properly plugged (§ 27.073).  Detailed
financial responsibility requirements also are contained in Chapter 331, Subchapter I of the state's UIC


  September 30, 1999                                                                        45

-------
regulations (331.141 to 331.144 TAG).  A permittee is required to secure and maintain a performance bond
or other equivalent form of financial assurance or guarantee to ensure the closing, plugging, abandonment,
and post-closure care of the injection operation. However, the requirement, unless incorporated into a
permit, applies specifically only to Class I and Class m wells (331.142 TAG).

Washington

       Washington is a Primacy state. Chapter 173-218 of the Washington Administrative Code (WAC)
establishes the underground injection control program. Under the program, the policy of the Department of
Ecology (WDOE) is to maintain the highest possible standards to prevent the injection of fluids that may
endanger ground waters which are available for beneficial uses or which may contain fewer than 10,000 mg/1
total dissolved solids (TDS). Consistent with that policy, new Class V injection wells that inject industrial,
municipal, or commercial waste fluids into or above a USDW are prohibited (172-218-090(1) WAC), and
existing wells that inject industrial, municipal, or commercial waste fluids into or above a USDW must obtain
a permit to operate.  All other Class V injection well owners and operators must notify the WDOE and
supply required inventory information (172-218-090 (2) and (3) WAC).

       Permitting

       A permit must specify conditions necessary to prevent and control injection of fluids into the waters
of the state, including all known, available, and reasonable methods of prevention, control, and treatment;
applicable requirements in 40 CFR Parts 124, 144, 146; and any conditions necessary to preserve and
protect a USDW. Any injection well that causes or allows the movement of fluid into a USDW that may
result in a violation of any primary drinking water standard under 40 CFR Part 141 or that may otherwise
adversely affect the beneficial use of a USDW is prohibited (173-218-100 WAC). The state's Waste
Discharge Permit Program, which prohibits the discharge of pollutants into waters of the state (which include
ground water) without a permit (Chapter 173-216 WAC) does not apply to the injection of fluids through
wells which are regulated by the UIC control program (173-216-010 WAC).

       Siting and Construction

       The state's minimum standards for construction and maintenance of wells require notice before
construction, reconstruction, or abandonment of a well, and submission of complete records describing
construction or alteration of a well (173-160-050 and 173-160-055 WAC).

       Wells are required to be planned and constructed to be adapted to the geologic and ground water
conditions at the well site and designed to facilitate conservation of ground water (173-160-065 WAC).

       The natural barriers to ground water movement between aquifers must be maintained, and aquifers
or strata penetrated during drilling must be sealed to prevent impairment of water quality or cascading water.
All  sealing must be permanent and prevent movement of surface or ground water into the annular space.
Sealing shall prevent the movement of ground water either upward or downward from zones that were
cased off because of poor quality. When cement grout is use in sealing, it must be set in place 72 hours


  September 30,  1999                                                                        46

-------
before additional drilling takes place, unless special additives are mixed with the grout that cause it to set in a
shorter period of time. All grouting must be performed by tremmying the mixture from the bottom of the
annular space to the surface in one continuous operation. The annual space to be grouted shall be a
minimum  four inches larger than the permanent casing. When casing diameter is reduced, a minimum of 8
feet of casing overlap is required and the bottom of the annular space between the casings shall be sealed
with a watertight packer. The remainder of the annular space must be pressure grouted with bentonite or
neat cement (173-160-075 WAC).

       Operating Requirements

       The water quality standards for ground waters establish an antidegradation policy.  The injectate
must meet the state ground water standards at the point of compliance (173-200-030 WAC).

       Plugging and Abandonment

       All wells not in use must be securely capped so that no contamination can enter the well
(173-160-085 WAC).
   September 30, 1999                                                                       47

-------
                                        REFERENCES

Adinolfi, M. and W. Ruck. 1992. Microbiological and Environmental Effects of Aquifer Thermal Energy
Storage. In: Aquifer Thermal Energy (Heat and Chill) Storage. Papers Presented at the 1992 Intersociety
Energy Conversion Engineering Conference. San Diego, California. August 3-4, 1992. Edited by E.A.
Jeanne. November 1992. Pages 69-74.

Andersson, O. and B. Sellberg. 1992.  Swedish ATES Applications: Experiences After Ten "Vears of
Development. Ibid. Pages 1-7.

Boise State University, Department of Geology. 1990. Letter from Associate Professor James Osiensky,
Boise State University Department of Geology and Geophysics, to Mr. Mark  Slifka, Idaho Department of
Water Resources, Re: Request for Drilling Permit for Hydrogeologic Testing at Eagle Island State Park,
October 22, 1990.

Boise State University, Department of Geology. 1990.  State of Idaho Department of Water Resources
Application No. 63-W-47, Application for Permit to Construct an Injection Well.  Associate Professor
James Osiensky, Boise State University Department of Geology and Geophysics, October 26, 1990.

The Cadmus Group. 1999.  State-by-State Notebooks Compiling Results from the Class V Underground
Injection Control Study, February  1, 1999.

Chant, Y and E. Morofsky. 1992.  Overview of Projects with Seasonal Storage for Cooling from Four
Countries. Ibid. Pages 17-21.

Gerba, C.P, and Bitton, G. 1984, Microbial pollutants: their survival and transport pattern to ground water:
in Bitton, G., and Gerba, C.P, (eds.) Ground Water Pollution Microbiology, John Wiley and Sons, Inc.,
New York.

Hall, S.H. and J.R. Raymond. 1992.  Geohydrologic Characterization for Aquifer Thermal Energy Storage.
In: Aquifer Thermal Energy (Heat and Chill) Storage. Papers Presented at the 1992 Intersociety Energy
Conversion Engineering Conference. San Diego, California. August 3-4, 1992. Edited by E.A. Jeanne.
November 1992. Pages 75-81.

Holm, T,R., S.J. Eisenreich, H.L.  Rosenberg, and N.P Holm. 1987.  Short-term Aquifer Thermal Energy
Storage Test Cycles. Water Resources Research 23(6): 1005-1019.

Holmbeck-Pelham, S.A. 1998.  Regulatory and Technical Suitability of Groundwater Tracers for the
Savannah River Site, South Carolina. A Thesis Submitted to the Graduate Faculty of the University of
Georgia in Partial Fulfillment of the Requirements for the Degree of Master of Science. Athens, GA.

Hoyer, M., J. Hallgren, S. Eisenreich, and R. Sterling. 1994.  Field-test Results of Aquifer Thermal Energy
Storage at St. Paul, Minnesota. Journal of Energy Engineering 120(2): 67-85.


  September 30,  1999                                                                       48

-------
Idaho Department of Water Resources. 1991. State of Idaho Department of Water Resources Attachment
I, Standard Conditions and Requirements Pertaining to Constructing, Operating, Modifying, Operating,
and/or Abandoning an Injection Well, Permit No. 63-W-47, May 28, 1991.

Idaho Department of Water Resources. 1991. State of Idaho Department of Water Resources Attachment
n, Special Conditions and Requirements Pertaining to Constructing, Operating, Modifying, Operating,
and/or Abandoning an Injection Well, Permit No. 63-W-47, May 28, 1991.

Jenne, E.A., O. Andersson, and A. Willemsen. 1992.  Well, Hydrology, and Geochemistry Problems
Encountered in ATES Systems and Their Solutions. In: Aquifer Thermal Energy (Heat and Chill) Storage.
Papers Presented at the 1992 Intersociety Energy Conversion Engineering Conference. San Diego,
California. August 3-4, 1992. Edited by E.A. Jeanne.  November 1992. Pages 51-62.

Jollien, L., S. Remonnay and F. Miserez. 1992.  Heat Storage at SPEOS (Swiss ATES Pilot Plant):
Chemical and Microbiological Aspects and Problems. Ibid. Page 41-46.

Koch, M. and W. Ruck. 1992.  Injection of CO2 for the Inhibition of Scaling in ATES Systems. Ibid. Pages
63-67.

Land, R. "Memo: Information on DOE Micca Mountain Project," Correspondence to Anhar Karimjee,
USEPA, OGWDW. December 1997.

Marseille, T.J. and D.A. Wilke. 1992. Review of the Aquifer Seasonal Thermal Energy Storage Building
HVAC System at the Melville, New %rk, Mid-Island Mail Facility. In: Aquifer Thermal Energy (Heat and
Chill) Storage. Papers Presented at the 1992 Intersociety Energy Conversion Engineering Conference. San
Diego, California. August 3-4, 1992. Edited by E.A. Jeanne. November 1992. Pages 117-122.

Mirza, C. 1994. Criteria for ATES Wells. In: Thermal Energy Storage: Better Economy, Environment,
Technology - Calorstock '94, 6th International Conference on Thermal Energy Storage, proceedings.
August 22-25, 1994. Espoo, Finland. Edited by M.T Kangas and PD. Lund. Helsinki University of
Technology, 1994. Pages 17-24.

Morofsky, E. 1997.  Aquifer Thermal Energy Storage,  Energy Efficiency, Economics, and the Environment.
Published at http://w3 .pwgsc.gc.ca/tech_env/dev/text/rdd/text/-energy/aqua-e.html

Parker, 1999. Mr. Randy Parker, Acting Assisting Director for Technology, National Risk Management
Research Laboratory, U.S. Environmental Protection Agency, USEPA SITE Program,
Cincinnati, Ohio. Telephone Conversation with Mr. Robert Lanza, P.E., ICF Consulting,  July 30, 1999.

Phillips, 1999.  Ms. Elizabeth Phillips, DNAPL Product Program Manager, Office of Science and
Technology, U.S. Department of Energy, Oak Ridge, Tennessee. Telephone Conversation with Mr. Robert
Lanza, P.E., ICF Consulting, July 30, 1999.
   September 30, 1999                                                                      49

-------
Seppaenen, H.T. 1994. Microbes and ATES, Illusions and Facts. In: Thermal Energy Storage: Better
Economy, Environment, Technology - Calorstock '94, 6th International Conference on Thermal Energy
Storage, proceedings. August 22-25, 1994. Espoo, Finland. Edited by M.T Kangas and P.D. Lund.
Helsinki University of Technology, 1994. Pages 615-622.

U.S. Department of Energy, Office of Civilian Radioactive Waste Management, Micca Mountain Site
Characterization Office. Underground Injection Control (UIC) Permit UNEV 89031 Annual Report for
1996.

U.S. Department of Energy, Office of Civilian Radioactive Waste Management, Micca Mountain Site
Characterization Office. Underground Injection Control (UIC) Permit UNEV 89031 Annual Report for
1997.

U.S. Department of Energy, Office of Civilian Radioactive Waste Management, Micca Mountain Site
Characterization Office. Underground Injection Control (UIC) Permit UNEV 89031 Fourth Quarter Report
for 1997.

U.S. Department of Energy, Office of Civilian Radioactive Waste Management, Micca Mountain Site
Characterization Office (No date). Schematic Diagram of Pneumatic Packed Tracer Injection Well for
Geologic Strata Tracer Studies at Micca Mountain Site.  Available:
http://www.ymp.gov/about/science/e_sci/pneuma.htm [1999, April]

U.S. Department of the Interior, Bureau of Mines. 1993. Situation Statement, U.S. Bureau of Mines Stope
Leaching Research Project, Colorado School of Mines Experimental  Mine, Class V Injection Well Rule
Authorization (USEPA File No. CO5000-03591), April 16,  1993.

U.S. Department of the Interior, Bureau of Mines. 1993. Letter from Ms. Nadia C. Miller, Environmental
Coordinator, Bureau of Mines, to Mr. Ron Zdyb, Underground Injection Control Implementation Section,
USEPA Region 8, September 14, 1993.

U.S. Department of the Interior, Bureau of Mines. 1993. Letter from Ms. Nadia C. Miller, Environmental
Coordinator, Bureau of Mines, to Mr. Ron Zdyb, Underground Injection Control Implementation Section,
USEPA Region 8, November 2, 1993.

U.S. Department of the Interior, Bureau of Mines. 1993. Letter from Ms. Nadia C. Miller, Environmental
Coordinator, Bureau of Mines, to Mr. Ron Zdyb, Underground Injection Control Implementation Section,
USEPA Region 8, December 7, 1994.

U.S. Department of the Interior, U.S. Geological  Survey (USGS). 1996. Letter from Mr. Peter B.
McMahon, Ph.D., Hydrologist, USGS Water Resources Division, Colorado District,  to Mr. Ronald Zdyb,
USEPA, July 28,  1996.
   September 30, 1999                                                                     50

-------
U.S. Department of the Interior, U.S. Geological Survey (USGS). 1996.  Letter from Mr. Peter B.
McMahon, Ph.D.., Hydrologist, USGS Water Resources Division, Colorado District, to Mr. Bob Becker,
USEPA, November 26, 1996.

USEPA. 1987. Report to Congress: Class V Injection Wells. Washington, D.C. Office of Water.
September 1987. USEPA 570/9-87-006.
USEPA, Region 8. 1993.  Letter from Mr. Thomas J. Pike, UIC Implementation Section, USEPA Region
8, to Mr. Edward E. Hollop, Research Director, U.S. Department of the Interior, Bureau of Mines. Re:
Underground Injection Control Class V Injection Well, Rule Authorization, Stope Leaching Research
Project, Colorado School  of Mines, Idaho Springs, CO (USEPA File No. CO5000-03591), April 20,
1993.

USEPA, Region 8. 1993.  Letter from Mr. Thomas J. Pike, UIC Implementation Section, USEPA Region
8, to Mr. Edward E. Hollop, Research Director, U.S. Department of the Interior, Bureau of Mines. Re:
Underground Injection Control Class V Injection Well, Rule Authorization Modification, Stope Leaching
Research Project, Colorado School of Mines, Idaho Springs, CO (USEPA File No. CO5000-03591),
August 25, 1993.

USEPA, Region 8. 1994.  Letter from Mr. Thomas J. Pike, UIC Implementation Section, USEPA Region
8, to Mr. Edward E. Hollop, Research Director, U.S. Department of the Interior, Bureau of Mines. Re:
Underground Injection Control Class V Injection Well, Rule Authorization Modification, Alternate Use of
Tracer Solution, Stope Leaching Research Project, Colorado School of Mines, Idaho Springs, CO
(USEPA File No. CO5000-03591), January 14, 1994.

USEPA, Region 8. 1998.  Letter from Mr. D. Edwin Hogle, Director, Groundwater Program, Office of
Partnerships and Regulatory Assistance, USEPA Region 8, to Mr. Gary Curtis, U.S. Geological  Survey,
Menlo Park, CA.  Re: Underground Injection Control Class V Injection Well, Rule Authorization, Small
Scale Tracer Study, Naturita Site, Naturita, CO. (USEPA File No. CO5000-03802), October 7, 1998.

Wilson, J., and Noonan, JJ. 1984.  Microbial Activity in Model I Aquifer Systems:  in Bitton, G, and
Gerba, C.P, (eds.) Ground Water Pollution Microbiology, John Wiley and Sons, Inc., New "Vbrk.
   September 30, 1999                                                                     51

-------