United States
Environmental Protection
Agency
EPA/600/R-07/032
February 2007
Evaluation of Fugitive
Emissions Using
Ground-Based Optical Remote
Sensing Technology
   Vertical Radial Plume Mapping Mass Emission Flux Measurement

-------
                                            EPA/600/R-07/032
                                               February 2007
Evaluation of Fugitive Emissions Using
Ground-Based Optical Remote Sensing
                   Technology
                       Prepared by

                     ARCADIS G&M, Inc.
                     Durham, NC27713
                     EPA Project Officer

                      Susan Thorneloe
              Air Pollution Prevention and Control Division
             National Risk Management Research Laboratory
                 Research Triangle Park, NC 27711
             National Risk Management Research Laboratory
                Office of Research and Development
                U.S. Environmental Protection Agency
                     Cincinnati, OH 45268

-------
                                           Notice
This document has been reviewed in accordance with the U.S. Environmental Protection Agency policy and
approved for publication. Mention of trade names or commercial products does not constitute endorsement or
recommendation for use.

-------
                                    Foreword
The  U.S. Environmental Protection Agency (EPA) is charged by Congress with protecting the
Nation's land, air, and water resources.  Under a mandate of national environmental laws, the
Agency strives to formulate and implement actions leading to a compatible balance between
human activities  and the ability to natural systems to support and  nurture life.  To meet this
mandate,  EPA's  research program  is providing data  and technical  support for solving
environmental problems today and building a science knowledge base necessary to manage our
ecological resources wisely, understand how pollutants affect our health, and prevent or reduce
environmental risks in the future.
The  National Risk Management Research  Laboratory (NRMRL) is the Agency's  center for
investigation of technological and management approaches for preventing  and reducing  risks
from pollution that threaten human health and the environment.  The focus of the Laboratory's
research program  is on methods and  their cost-effectiveness  for prevention and  control of
pollution to air, land, water, and subsurface resources; protection of water quality in public water
systems; remediation of contaminated sites, sediments and groundwater; prevention and control
of indoor air pollution; and restoration of ecosystems.  NRMRL collaborates with both  public and
private sector partners to foster technologies that  reduce the cost of compliance  and  to
anticipate emerging problems. NRMRL's research provides solutions to environmental problems
by developing and promoting technologies that protect and improve the environment;  advancing
scientific and  engineering information to support regulatory and policy decisions;  and providing
the technical support and  information  transfer to  ensure implementation of environmental
regulations and strategies at the national, state, and community levels.
This publication has been  produced as part of the Laboratory's strategic long-term research
plan.  It is published and made available by EPA's Office of Research and Development to
assist the user community and to link researchers with their clients.
                                      Sally Gutierrez, Director
                                      National Risk Management Research Laboratory

-------
                                         Abstract
EPA has developed and evaluated a method for characterizing fugitive emissions from large area
sources. The method,  known as radial plume mapping (RPM), uses multiple-beam, scanning, optical
remote sensing (ORS) instrumentation such as  open-path  Fourier transform infrared spectroscopy,
ultraviolet differential absorption spectroscopy, open-path tunable diode spectroscopy, and open-path
tunable  diode  laser  absorption  spectroscopy  in  unique  radial configurations  and  optimization
algorithms providing essential spatial data for emission calculations.  The RPM method can be used
for  characterizing emissions from  a  wide  range of area  sources,  including landfills, wastewater
treatment plants, and agricultural operations. This report represents a three-year effort conducted to
evaluate the feasibility of using ORS instrumentation to measure landfill gas emissions, which include
methane, volatile organic compounds, and air toxics.
                                                                                          IV

-------
                                              Contents
Foreword                                                                    iii

Abstract                                                                     iv

Tables                                                                       viii

Figures                                                                      ix


1.  Introduction                                                              1


2.  Overview of Optical Remote Sensing with the Radial Plume Mapping
    Method, and other Traditional Monitoring Approaches                      3

      2.1    Background                                                        3

      2.2    HRPM Method                                                      4

      2.3    VRPM Method                                                      6

      2.4    Alternative VRPM Approach                                           8

      2.5    Comparison to Other Measurement Approaches                           9


3.  Summary of Optical Remote Sensing Technologies                       12

      3.1    OP-FTIR                                                         13

      3.2    OP-TDLAS                                                       14

      3.3    UV-DOAS                                                        16

            3.3.1    Evaluation of OP-FTIR Instrumentation                          17

            3.3.2    Evaluation of OP-TDLAS Instrumentation                         18

            3.3.3    Evaluation of UV-DOAS Instrumentation                          19

            3.3.4    Comparison of Methane Data Collected with the IMACC OP-FTIR
                   and Unisearch OP-TDLAS Instruments                          19


4.  Summary of Project Field Campaigns                                    23

      4.1    Difficulties in the Application of the RPM Method at Landfill Sites             28

            4.1.1    Sites with Elevated Passive Vents                              28

            4.1.2    Measurement of Methane Emissions from Slopes of Sites           29

            4.1.3    Capture of Emissions from Hot Spots Located a Large Distance
                   Upwind of the VRPM Configuration                              31

-------
            4.1.4    Prevailing Wind Direction During the Time of the Measurements       31





5.  Orange County, NC Field Campaign                                        33



      5.1    Site Information                                                       33



      5.2    Project Objectives                                                    35



      5.3    Testing Procedures                                                   35



      5.4    Active Site                                                           36



            5.4.1    HRPM Measurements                                          36



            5.4.2    VRPM Measurements                                          37



      5.5    Closed Site                                                          38



            5.5.1    HRPM Measurements                                          38



            5.5.2    VRPM Measurements                                          38



      5.6    Addressing Potential Difficulties with Applying the RPM Method to the Site     40



      5.7    Development of Real-Time Analysis Capabilities                           40





6.  VRPM Plume Capture Validation Study                                     42



      6.1    Background Information and Study Objectives                             42



      6.2    Testing Procedures                                                   42



      6.3    Procedure for Plume Capture Assessment                                47



      6.4    Results and Discussion                                                48



            6.4.1    20-Meter Releases                                             48



            6.4.2    60-Meter Releases                                             50



            6.4.3    100-Meter Releases                                            50



            6.4.4    140-Meter Releases                                            52



      6.5    Summary of Release Results                                           54



      6.6    Assessment of Plume Capture                                          55



      6.7    Conclusions from the Results of the Study                                56



      6.8    QA/QC                                                              57



            6.8.1    Equipment Calibration                                          57
                                                                                                         VI

-------
            6.8.2   Assessment of DQI Goals                                      57

            6.8.3   DQI Check for Analyte PIC Measurement                          58

            6.8.4   DQI Checks for Ambient Wind Speed and Wind Direction Measurements     60

            6.8.5   DQI Checks for the Topcon Theodolite                            61

            6.8.6   QC Checks of OP-FTIR Instrument Performance                   61


7.  Quality Assurance Methods                                               63

      7.1    ORS Instrumentation Calibration                                        64

            7.1.1   Quality Assurance of the OP-FTIR Instruments                     64

            7.1.2   Quality Assurance of Unisearch OP-TDLAS Instrument              65

            7.1.3   Quality Assurance of the Boreal OP-TDLAS Instrument              67

      7.2    Non-ORS Instrumentation Calibration                                    68

      7.3    VRPM Tracer Release Validation Study                                  68

      7.4    Comparison of Methane Concentration Determination Using the Two
            Software Packages                                                   70


Acknowledgements                                                            74


References                                                                    75
Appendices

      Appendix A.  Radial Plume Mapping Algorithms


      Appendix B:  Results from the Chapel Hill, NC Field Campaign


      Appendix C:  Methane Emissions Results from the VRPM Validation Study Conducted
                  During June and July, 2006


      Appendix D:  ORS Instrument Manufacturers
                                                                                                        VII

-------
                                          Tables
Table 1. Summary of the advantages and disadvantages of ORS-based and
      traditional point monitor approaches                                      10

Table 2. Summary information on the ORS instrumentation and other traditional
      monitors                                                             11

Table 3. Summary information on the ORS instrumentation used                    12

Table 4. Summary of ORS instrumentation used for each measurement campaign     12

Table 5. Comparison of methane concentrations (in ppm) measured with the
      OP-TDLAS and OP-FTIR instruments                                    20

Table 6. Summary of methane flux values measured during the VRPM surveys in
      the active site                                                         38

Table 7. Summary of methane flux values measured during the VRPM surveys in
      the closed site                                                         40

Table 8. Results of the t-test performed using sulfur hexafluoride concentration
      data collected along beam path 4 and 5 during the 100-meter release          46

Table 9. Example dataset from the executed experimental  design                   47

Table 10. Average calculated flux values from the 60, 100, and 140 meter
      releases*                                                             54

Table 11. Plume capture percentages determined along the long VRPM
      configuration from the 60-, 100-, and  140-meter releases                    55

Table 12. Plume capture percentages determined along the long VRPM
      configuration from the 60-, 100-, and  140-meter releases                    56

Table 13. Instrumentation calibration frequency and description                     59

Table 14. Data quality indicator goals for the project                               60

Table 15. Summary of calibration results of the Unisearch OP-TDLAS instrument     66

Table 16. Accuracy of concentration measurements for different R2values            67

Table 17. Instrumentation calibration frequency and description                     68

Table 18. Summary of the advantages and disadvantages  of applying the RPM
      method to different types of measurement sites                            73
                                                                                                        VIM

-------
                                               Figures
Figure 1. Example HRPM configuration showing the location of the ORS
      instrument, and the beam paths used for the survey                          4

Figure 2. Example surface methane concentration contour map generated using
      the HRPM method (concentrations shown in ppmv)                          5

Figure 3. Example of a VRPM configuration deployed downwind of the survey
      area                                                                  6

Figure 4. Example plume map generated using the VRPM method (concentrations
      shown in ppmv). The location of the vertical structure is shown by the solid
      black vertical line. The scanning ORS instrument is located in the bottom
      left-hand corner of the figure                                              7

Figure 5. Schematic of the Alternative VRPM Approach                             8

Figure 6. Unisearch Associates OP-FTIR instrument and scanner                   13

Figure 7. IMACC OP-FTIR instrument and scanner                                14

Figure 8. Unisearch OP-TDLAS system                                          15

Figure 9. Boreal OP-TDLAS system and scanner                                 15

Figure 10. Opsis UV-DOAS system                                             16

Figure 11. Comparison of methane concentrations measured along similar beam
      paths during the Fort Collins measurement campaign with the OP-FTIR
      and OP-TDLAS instruments                                             21

Figure 12. Surface methane concentration contours (in ppmv) overlaid on the map
      of the Somersworth Superfund Landfill                                    23

Figure 13. Reconstructed methane plume map from the VRPM survey of the
      Somersworth site (concentrations shown in ppmv). The location of the
      vertical structure is shown by the solid black vertical line. The scanning
      ORS instrument is located in the  bottom left-hand corner of the figure          24

Figure 14. Summary map from the Fort Collins, CO site showing the surface
      gasoline concentration contour map (concentration shown  in ppbv), and
      suspected source location of the  measured methane and ammonia            25

Figure 15 Surface methane concentration contours (in ppmv) overlaid on the map
      of the Colorado Springs,  CO site. The figure shows the location of the
      VRPM configuration at the site                                           26

Figure 16. Reconstructed methane plume map from the VRPM survey of the
      Colorado Springs, CO site (concentrations shown  in ppmv). The location of
      the vertical structure is shown by the solid black vertical line. The scanning
      ORS instrument is located in the  bottom left-hand corner of the figure          27

Figure 17. Passive vents sealed with plastic at the Colorado Springs site             29
                                                                                                         IX

-------
Figure 18. Schematic of the OP-TDLAS configuration deployed along the southern
      slope of the Colorado Springs site                                         30

Figure 19. Site map of the Orange County Municipal Landfill site showing the
      location of the two landfill areas                                           33

Figure 20. Closed landfill site at the Orange County Municipal Landfill                34

Figure 21. Active landfill site at the Orange County Municipal Landfill                 35

Figure 22. Map of the active site showing the location of the survey areas and
      prevailing wind direction during the time of the surveys                       37

Figure 23. Map of the closed site showing the location of the survey areas and
      prevailing wind directions during the time of the surveys                      39

Figure 24. Schematic of the experimental configuration used for the VRPM
      validation study                                                         43

Figure 25. Time series of wind  direction and calculated sulfur hexafluoride fluxes
      from the 20 meter release (as analyzed along the 200 meter VRPM
      configuration)                                                           49

Figure 26. Time series of acetylene and sulfur hexafluoride flux values from the 60
      meter release survey                                                    51

Figure 27. Time series of acetylene and sulfur hexafluoride flux values from the
      100 meter release survey                                                52

Figure 28. Time series of acetylene and sulfur hexafluoride flux values from the
      140 meter release survey                                                53

Figure 29. Plot of the Unisearch OP-TDLAS instrument calibration response          66

Figure 30. Reconstructed ethylene plume from the VRPM validation study
      conducted during the Somersworth, NH field campaign (concentrations
      shown in ppmv). The location of the vertical structure is shown by the solid
      black vertical line. The scanning ORS instrument is located in the bottom
      left-hand corner of the figure                                              69

Figure 31. Comparison of methane concentration analysis using the Non-Lin and
      IMACCQuant software packages                                          71

Figure 32. Comparison of real-time and post-collection methane concentration
      analysis using the IMACCQuant software package                          71

-------
                                        1.  Introduction

Over the last several years, the Air Pollution Prevention and Control Division (APPCD) of the US EPA's
National Risk Management Research Laboratory (NRMRL), and ARCADIS, have developed and evaluated
a method for characterizing fugitive emissions from large area sources. The method, known as Radial
Plume Mapping (RPM) [Hashmonay et al., 1998; Hashmonay et al., 2001], uses multiple-beam, scanning,
Optical Remote Sensing (ORS) instrumentation such as Open-Path Fourier Transform Infrared (OP-FTIR)
Spectroscopy, Ultraviolet Differential Absorption Spectroscopy (UV-DOAS), and Open-Path Tunable Diode
Laser Absorption Spectroscopy (OP-TDLAS) in unique radial configurations and optimization algorithms,
providing essential spatial data for emission calculations. The RPM method can be used for characterizing
emissions from a wide range of area sources, including landfills, wastewater treatment plants, and
agricultural operations [Shores et al., 2004; Thoma et al., 2005].

Measuring emissions from landfill sites presents unique challenges due to the large source area, spatial and
temporal variability of emissions, and the wide variety of target pollutants present in landfill gas. The current
project represents a three-year effort conducted to evaluate the feasibility of using ORS instrumentation to
measure landfill gas emissions, which include methane, volatile organic compounds (VOC), and air toxics.
Landfill gas emissions have been found to be a concern to the environment, as well as human health due to
the explosive potential of the gas, emissions of hazardous air pollutants and volatile organic compounds,
emissions of methane that contribute to climate change, and odor nuisance associated with landfill gas. The
United States Environmental Protection Agency (U.S. EPA) has promulgated regulations under the Clean
Air Act to address the public health concerns of landfill  gas emissions. The final rule and guidelines are
contained in 40 CFR Parts 51, 52, and 60, Standards of Performance for New Stationary Sources and
Guidelines for Control of Existing Sources: Municipal Solid Waste Landfills.

The long-term study evaluation is based on several factors including target compounds, minimum detection
levels of the instrumentation for the target compounds,  resources necessary for deployment of each
instrument,  and resources needed for data analysis. Some of the site-specific issues affecting this evaluation
are the size of the survey area, topography of the site, location of passive vents, and physical barriers at the
site such as buildings and other structures. The project consisted of measurement campaigns at a
Superfund site  in Somersworth, New Hampshire (Modrak et al., 2004), a former landfill site in Fort Collins,
Colorado (Modrak et al., 2005a), a formal landfill site in Colorado Springs, Colorado (Modrak et al., 2005b),
and a measurement campaign and technology demonstration at the Orange County Municipal Landfill in
Chapel Hill, North Carolina. Additionally, project members conducted a study to validate the RPM method.
This long-term ORS evaluation study was funded by the U.S. EPA Office of Superfund Remediation and
Technology Innovation, Technology Integration and Information Branch (TUB) under its Monitoring and
Measurement for the 21st Century (21M2) initiative. More information on the 21M2 initiative can be found at
on the web at http://www.clu-in.orq/proqrams/21m2.

-------
This report presents a summary of the long-term evaluation of using the ORS instrumentation with the RPM
method for conducting measurements in active or former landfill sites. The findings of this report can be
used as guidance for selection of the appropriate ORS instrument for use with the RPM method for a
particular application.

-------
     2.  Overview of Optical Remote Sensing with the Radial Plume Mapping Method and Other
                                 Traditional Monitoring Approaches

2.1  Background

Open-path optical remote sensing (ORS) technologies have been used for many years as a powerful tool for
measuring air emissions. ORS instruments measure path-integrated concentration (PIC) data along a
configuration beam path, which is defined as the distance between the instrument detector and the retro-
reflecting mirror, or the instrument light source, depending on the type of instrument used. The ORS beam
path length typically ranges from 50 to 500 meters, depending on the instrument and application. The major
advantage of ORS instrumentation over traditional point monitors is the ability to provide greater spatial
information of the monitored area, reducing the chance of missing emissions hot spots.

For several years, researchers have been using ORS data to characterize fugitive emissions using methods
such as inverse dispersion modeling, Backward Lagrangian Stochastic (BLS) modeling, and tracer gas
releases. A major advancement in the application of ORS instrumentation (for measuring emissions from
large area  sources) was the advancement of the Radial Plume Mapping (RPM) method, which was
developed at the University of Washington in the mid-1990s [Hashmonay and Yost, 1999; Hashmonay et al.,
1999]. The method, which can be applied using any scanning ORS instrument, collects path-integrated
concentration data along multiple beam paths in the configuration. Multiple retro-reflecting mirrors are
deployed in the survey area to define the beam paths used in the survey. The ORS instrument can be
scanned in a horizontal plane (Horizontal Radial Plume Mapping) to produce surface concentration contour
maps, showing the location of localized surface emissions hot spots. The ORS instrument can also be
scanned in a vertical plane deployed downwind of the survey area (Vertical Radial  Plume Mapping) to map
the emissions plume downwind of the area of interest.  By including meteorological data collected
concurrently with the ORS measurements, the Vertical Radial Plume Mapping method can be used to
calculate the downwind emission flux from the site.

In recent years, work was done by ARCADIS, U.S. EPA, and the U.S. Department of Defense to
demonstrate and validate the RPM method in a series  of controlled-release experiments. As a result of this
work, a protocol for applying the RPM method (Radial Plume Mapping Method for Emissions
Characterization from  Non-Point Sources) was developed and peer reviewed, and  the RPM method is now
approved as  EPA Other Test Method 10 (OTM-10). A copy of OTM-10 can be viewed at
http://www.epa.gov/ttn/emc/tmethods.html. OTM-10 is  the only documented EPA-approved method for
characterizing fugitive  emissions from area sources.

-------
2.2  HRPM Method

Horizontal Radial Plume Mapping (HRPM) is a technique that can be used to identify the location of locally
higher areas of surface emissions, or hot spots, within the survey area. The technique can be used to
perform surveys in areas with dimensions as large as 250 meters. The HRPM method uses one scanning
ORS instrument, which is usually deployed in the corner of the survey area. Between four and twelve mirrors
are deployed in a radial pattern along the surface of the survey area. The exact deployment location of the
mirrors is pre-determined using a computer-based coordinate program. The ORS instrument scans along
each path length in the configuration, collecting path-integrated concentration data. This data is input into the
HRPM algorithm to produce surface concentration contour maps.

Figure 1 shows a schematic of an example HRPM configuration. In this example, nine mirrors are used in
the configuration, and the dimensions of the survey area are approximately 120 meters by 120 meters.

Figure 2 shows an example methane surface concentration contour map generated by the HRPM method in
a landfill.  Concentrations are shown in ppmv. The red dot indicates the location of the scanning ORS
instrument.
                                                                100
Figure 1.    Example HRPM configuration showing the location of the ORS instrument, and the beam paths used
           for the survey

-------
                             100
                                     10    20    30    40    50
                                               X
                                                                   N
   Figure 2. Example surface methane concentration contour map generated using the HRPM method
           (concentrations shown in ppmv)
The HRPM method is used to provide qualitative information on the location of hot spots in a survey area.
This information can be used as guidance in selecting the location of the VRPM configuration, which is
discussed in the next section. The data generated with the HRPM method can also be useful to landfill
operators, as they can provide information on the general location of surface methane leaks. More
information on the HRPM algorithm can be found in Appendix A of this document.

-------
2.3  VRPM Method

Vertical Radial Plume Mapping (VRPM) surveys are performed at a site after completion of the HRPM
surveys. When a surface hot spot is located, the VRPM configuration is deployed downwind, with the
configuration centered around the detected hot spot (see Figure 3). The VRPM configuration should be
deployed so that the prevailing wind direction is as close to perpendicular to the plane of the configuration as
possible.
            Figure 3. Example of a VRPM configuration deployed downwind of the survey area
The VRPM configuration consists of a scanning ORS instrument, a scissors jack or similar vertical structure
(between 5 and 15 meters high) deployed between 50 and 250 meters from the instrument, and multiple
mirrors. Typically, three mirrors are deployed along the ground between the ORS instrument and the vertical
structure, one mirror is mounted midway up the vertical structure, and one mirror is mounted on top of the
vertical structure. Wind speed and wind direction data are collected near the base  of the vertical structure,
and at the top of the vertical structure. Path-integrated concentration data is collected  along each beam path

-------
in the configuration. This data is input into the VRPM algorithm with wind data (collected concurrently) to
produce an emissions plume map and downwind emissions flux value. Figure 4 shows an example methane
plume map generated using data collected  in a landfill. The ORS instrument was located in the lower left
corner of the figure, and the location of the vertical structure is indicated by the solid black line.
Concentrations are shown in ppmv. The methane flux calculated by the VRPM method was 4.9 grams per
second.
                                        100       ISO       200
                                         Crosswind Distance jmelers]
                                                                   210
Figure 4.    Example plume map generated using the VRPM method (concentrations shown in ppmv). The
           location of the vertical structure is shown by the solid black vertical line. The scanning ORS
           instrument is located in the bottom left-hand corner of the figure
Flux data from the VRPM algorithm can be used to estimate an emission factor from the area of interest.
The flux values calculated by the VRPM method (in units of mass per unit time) are divided by the surface
area of the upwind area contributing to the measured emissions to yield an estimated emission factor from
the survey area (in units of mass per unit time per unit area). Thus, the VRPM method can be used to
estimate a direct, measurement-based emission factor, without the need for dispersion modeling. More
information on the VRPM algorithm can be found in Appendix A of this document.

-------
2.4 Alternative VRPM Approach
The previous section describes the VRPM method, which was utilized for emissions characterization during
each of the field campaigns of this long-term project.  However, in recent months, an alternative VRPM
approach has been developed and applied in other projects.  The alternative approach was developed in
response to concerns about capturing emission from the slopes of landfill cells (discussed in Section 4.1.2),
as well as the reliance on prevailing wind directions during the measurements (discussed in Section 4.1.4).

The alternative approach consists of deploying four VRPM configurations using two vertical structures and
two scanning ORS systems. Figure 5 presents an overhead  schematic of the configuration.
     Figure 5. Schematic of the Alternative VRPM Approach

-------
Two scanning ORS instruments are deployed on top of each measurement area, in opposite corners of the
landfill cells. Each instrument is scanned to two five-beam VRPM configurations. The data collected along
the four VRPM measurement configurations is used to characterize emissions from the slopes of the landfill
(or upwind areas), as well as emissions from the actual landfill cell, depending on the direction of the
prevailing winds during the time of data collection. The major advantages of this approach are:

    1.  No reliance on wind direction for VRPM flux calculations. Once the configuration has been
       deployed, flux measurements can be collected, regardless of wind direction. Since data can be
       collected during any wind conditions, there is no need to wait for periods of favorable winds,
       allowing data to be collected in a survey area for a longer period of time.  This is especially
       favorable for projects with limited resources.

    2.  The ability to more directly characterize emissions from the side slopes.
2.5  Comparison to Other Measurement Approaches

In the past, other measurement approaches have been used to obtain emissions measurements in landfills
and other area sources. These include traditional point sampling instrumentation such as PID, PID/FID,
Summa canisters, various sorbent methods, and flux boxes. Although these approaches are generally
easier to deploy, less costly than ORS-based measurement approaches, and do not rely on prevailing wind
direction during the time of measurements, they only provide concentration information from a single point in
the survey area, greatly increasing the chances of missing surface emissions hot spots or emissions plumes.
Even after collecting data from multiple points in the survey area, the point sampling approaches lack the
spatial and temporal data necessary to obtain a complete picture of the emissions from large area sources.
Additionally, the flux box approach may not accurately characterize surface emissions from the site, as
deployment of the flux box on the surface of the landfill cell may not allow actual emissions to escape from
the landfill in the vicinity of the deployment area. Another disadvantage of using the point sampling
approaches is that it is necessary to use dispersion modeling to obtain flux data from the site. Table 1
presents a summary of the advantages and disadvantages of the ORS-based, and traditional point monitor
approaches.

-------
Table 1.    Summary of the advantages and disadvantages of ORS-based and traditional point monitor
           approaches
        Measurement Method
Advantages
Disadvantages
       ORS-Based Approach Using
       Radial Plume Mapping
Measurements collected over
a larger area making it less
likely to miss major emissions
areas

Better spatial and temporal
resolution

Direct, measurement-based
emissions calculations
Instrumentation is more costly

Requires more time and effort to
deploy

Relies on prevailing wind direction
for emissions measurements
       Traditional Point Monitors
Easy to deploy

Less costly to deploy

No reliance on prevailing wind
direction for measurements
Only provides data from a single
measurement point

Lack of spatial and temporal data

Possibility of missing major
emissions areas

Requires modeling to obtain
emissions calculations
Sections 6 and 7 of this document present the results of RPM validation studies done using controlled
releases of tracer gases. The studies found that the VRPM method had capture rates as high as 97% of the
actual emissions released during the study. An additional RPM validation study using multiple tracer gases
also found favorable capture rates when using the VRPM method, as well as favorable results using the
HRPM method (Varma et al., 2005).

Table 2 presents a comparison of traditional point monitoring approaches, and ORS-based approaches
using RPM. The table includes approximate costs of instrumentation, number of target compounds each
approach is capable of detecting simultaneously, minimum detection limits (MDL), spatial resolution of each
measurement technique, and number of personnel necessary for deployment. The table does not include
labor costs associated with field personnel or data analysis.
                                                                                                          10

-------
Table 2. Summary information on the ORS instrumentation and other traditional monitors
Measurement Approach
Scanning OP-FTIR with RPM
Scanning OP-TDLAS with RPM
Scanning UV-DOAS with RPM
ORS/RPM-Based Field
Campaign Conducted by
Environmental Contractor
PID
PID/FID
Summa Canister
Flux Boxes
Sorbent Methods
Equipment
Cost
$125,000a
$75,000a
$200,000a
$20, 000 to
$40,000/weekb
$10,000
$10,000C
$350 per
sampled
$1,000e
Varies
Number of
Target
Compounds
See Table 2
See Table 2
See Table 2
See Table 2
Total VOC
Total VOC
Multiple
Multiple
Varies
MDL
(PPb)
1 to 100
1 to 100
1 to 100
1 to 100
1 to 1 00
1 to 1 00
0.1 to 0.5
0.1 to 0.5
0.1 to 0.5
Spatial
Resolution
Entire Survey Area
Entire Survey Area
Entire Survey Area
Entire Survey Area
Single Point
Single Point
Single Point
Single Point
Single Point
Personnel
Needed for
Deployment
3
2
2 to 3
2 to 3
1
1
1
1
1
aCost includes ORS instrument, scanner, and retro-reflecting mirrors
bCost includes creation of quality assurance documentation, conducting field campaign, data analysis, and reporting. The
cost could vary depending on the size of the site and number of survey areas.
cDoes not include the cost of hydrogen needed at the site to operate the instrument
dDoes not include the cost of a gas chromatograph needed to analyze sample
eCost includes materials for constructing box, but does not include the cost of  sample analysis, which are typically
collected with summa canisters or FID instrumentation

It should be noted that the measurement approaches shown in Table 2 can be performed as a service by an
environmental contractor, meaning that an initial  capital investment for equipment is not necessary. The
approximate costs of hiring an environmental contractor to conduct a five-day field campaign using an
ORS/RPM based approach are typically between $20,000 and $40,000, depending on the size of the site,
number of survey areas, and target compounds of the study. The cost  includes creation of quality assurance
documentation, data collection, data analysis, and reporting.

In comparing the costs of an ORS-based measurement approach with  traditional point monitoring
approaches, an ORS-based approach using the  RPM method may be  more cost-effective. The ORS-based
approach provides much better spatial and temporal resolution of concentration data, allowing for
characterization of emissions plumes and direct calculation of emissions fluxes. In order to achieve the same
level of temporal and spatial resolution (and speciation of the target analyte) using traditional point monitors,
the user would have to deploy a multitude of monitors simultaneously at the site, resulting in substantially
increased sampling and analysis costs.
                                                                                                          11

-------
                     3.  Summary of Optical Remote Sensing Technologies

The project team evaluated many different ORS-based instruments as part of this long-term project,
including OP-FTIR, OP-TDLAS, and UV-DOAS. Table 3 presents background information on the ORS
instrumentation used during the long-term project. The table lists the analytes measured by each instrument,
cost of instrumentation, and instrument limitations such as weather and interfering species. Table 4 presents
a summary of the instrumentation used for each of the four measurement campaigns.

Table 3. Summary information on the ORS instrumentation used

Wavelength Range
Detectable Compounds
Detection Limits
Limiting Weather Conditions
Interfering Species
Instrumentation Cost
OP-FTIR
Infrared
(2-20 microns)
Multiple
Parts per billion
Heavy rain
Carbon dioxide, water
$125,000a
OP-TDLAS
Near Infrared
(approx. 1.5 microns)
CO, CO2, NOX, NH3,
CH4] H2S and others
Parts per billion
Heavy rain, fog
None
$75,000a
UV-DOAS
Ultraviolet
(245-380 nanometers)
BTEX, NH3], CO, CO2,
mercury, and other VOC
Parts per billion
Heavy rain, fog
Oxygen, ozone
$200,000a
aCost includes ORS instrument, scanner, and retro-reflecting mirrors
Table 4. Summary of ORS instrumentation used for each measurement campaign
Somersworth, NH
Unisearch OP-FTIR



Ft. Collins, CO
Unisearch OP-FTIR
IMACC OP-FTIR
Unisearch OP-TDLAS
OPS IS UV-DOAS
Colorado Springs, CO
Unisearch OP-FTIR
IMACC OP-FTIR
Unisearch OP-TDLAS
OPSIS UV-DOAS
Orange Co., NC
IMACC OP-FTIR
Unisearch OP-TDLAS
Boreal OP-TDLAS

RPM Validation Study
IMACC OP-FTIR
AIL OP-FTIR


The following subsections provide an overview of each of the ORS instruments used during the long-term
evaluation. A list of ORS instrument manufacturers and their contact information can be found in Appendix D
of this document.
                                                                                                    12

-------
3.1  OP-FTIR

The OP-FTIR Spectrometer is designed for both fence-line monitoring applications, and real-time, on-site,
remediation monitoring and source characterization. An infrared light beam, modulated by a Michelson
interferometer is transmitted from a single telescope to a retro-reflecting mirror target, which is usually set up
at a range of 100 to 500 meters. The returned light signal is received by the single telescope and directed to
a detector. The  light is absorbed by the molecules in the beam path as the light propagates to the retro-
reflecting mirror and again as the light is reflected back to the analyzer. Thus, the round-trip  path of the light
doubles the chemical absorption signal. One advantage of OP-FTIR monitoring is that the concentrations of
a multitude of infrared absorbing gaseous chemicals can be detected and measured simultaneously, with
high temporal resolution.

A scanning OP-FTIR  instrument manufactured by Unisearch Associates, Inc. was used for the
Somersworth, Fort Collins, and Colorado Springs studies. A scanning OP-FTIR manufactured by IMACC,
Inc. was used for data collection in the Fort Collins, Colorado Springs, and Chapel Hill studies. Both OP-
FTIR instruments contain a Nicolet bench,  12-inch telescope, and can collect data at resolutions of 0.125
cm"1, 0.25 cm"1, 0.5 cm"1,1 cm"1, 2 cm"1, 4 cm"1, and 8 cm"1. Figures 6 and 7 present pictures of the
Unisearch Associates OP-FTIR, and the IMACC OP-FTIR, respectively.
          Figure 6. Unisearch Associates OP-FTIR instrument and scanner
                                                                                                        13

-------
                          Figure 7. IMACC OP-FTIR instrument and scanner
3.2  OP-TDLAS

The OP-TDLAS instrument is a fast, interference free, and sensitive technique, for making continuous
concentration measurements of many gases. Concentrations in the range of part per billions are suitable for
measurements over an open path up to 1 km, for gases such as CO, CO2, NOX, NH3, and CH4 The laser
emits radiation at a particular wavelength when an electrical current is passed through it. The light
wavelength depends on the current and therefore allows scanning over an absorption feature and analyzing
for the target gas concentration, using Beer's law. The OP-TDLAS applies a small 4-inch telescope, which
launches the laser beam to a retro-reflecting mirror. The laser beam is returned by the mirror to the
telescope, which is connected with fiber optics to a control box that houses the laser and a multiple channel
detection device. A multiple channel OP-TDLAS instrument (Unisearch Associates, Inc.) was used during
the Fort Collins, Colorado Springs, and Chapel Hill field campaigns. This instrument uses multiple
telescopes to collect path-integrated methane concentration data along multiple beam paths (up to 8
beams). A single channel OP-TDLAS (Boreal, Inc.) was used during the Chapel Hill field campaign. The
instrument is mounted to a scanner, and collects path-integrated concentration data along five beam paths.
Figures 8 and 9 show pictures of the Unisearch OP-TDLAS and Boreal OP-TDLAS systems, respectively.
                                                                                                      14

-------
Figure 8. Unisearch OP-TDLAS system
          Figure 9. Boreal OP-TDLAS system and scanner
                                                                                   15

-------
3.3  UV-DOAS

The UV-DOAS instrument (OPSIS, Inc.) has proven to be particularly useful for determination of the
concentration of unstable species like free radicals,nitrous acid, and others (Cowen etal., 2004, Kelly et al.,
2003, Myers etal., 2000). Additionally, many of the aromatic species can be determined at high sensitivity
(Platt, 1994). UV-DOAS, like all spectroscopic techniques, makes use of the absorption of electromagnetic
radiation by matter (Beers law). While the strong, structured UV absorption features of aromatic
hydrocarbons have been  known for a long time,  it only recently became possible to use these properties for
the reliable, sensitive, and selective measurement of monocyclic aromatics by UV-DOAS. UV-DOAS
measurements of trace gases can be an extremely valuable complement to more traditional techniques like
OP-FTIR. It allows the sensitive detection of a series of relevant molecules with good time resolution. The
UV-DOAS instrument was used during the Fort Collins and Colorado Springs field campaigns. The
instrument was used to measure concentrations  of benzene, toluene, and xylene along a single-path
configuration. Figure 10 presents a picture of the OPSIS UV-DOAS system.
                   Figure 10. Opsis UV-DOAS system
                                                                                                     16

-------
The following subsections provide a summary of the evaluation of each ORS instrument used during the
long-term evaluation study. The subsections discuss the performance of each instrument, ease of
deployment, and advantages and limitations of each instrument. The last subsection presents a comparison
of methane data collected with the IMACC OP-FTIR and Unisearch OP-TDLAS instruments during the Fort
Collins measurement campaign.

3.3.1   Evaluation of OP-FTIR Instrumentation

Scanning OP-FTIR  instruments were used as the primary instrument for each field campaign of the long-
term evaluation project. The evaluation included two OP-FTIR instruments (Unisearch, Inc. and IMACC,
Inc.). The OP-FTIR  instruments were scanned to collect path-integrated methane concentration data over
multiple beam paths at the sites. Additionally, the OP-FTIR data was analyzed for the presence of ammonia
and VOCs at the sites. The OP-FTIR detected ammonia, methanol, and gasoline (primarily octane) during
the Ft. Collins and Colorado Springs field campaigns at ppb concentrations. The major advantage of the OP-
FTIR (over the other ORS instruments used in the long-term evaluation project) is the ability to detect
multiple compounds from the same data set. In fact, the OP-FTIR is the most cost-effective ORS instrument
for applications where it is necessary to measure multiple compounds. Both OP-FTIR instruments were
extremely stable and reliable over the course of the four field campaigns, with little or no maintenance
required (Modraketal., 2005a, Modraketal., 2005b).

One of the disadvantages of the OP-FTIR is the effort needed for deployment of the instrument. During the
long-term evaluation project, the OP-FTIR was deployed in multiple locations at each site. Although the
instrument is mounted on a scanner, it requires at least two technicians to mount the instrument to  the
scanner cart and deploy the scanner cart to the measurement area. However, the effort needed for
deployment of the OP-FTIR would not be an issue for applications where the OP-FTIR instrument is
deployed in a single configuration. Once the instrument has been deployed, it must be aligned on each
mirror used in the configuration. Alignment of the instrument is done using the scanner joystick control,
which makes the alignment process quick and simple.

In recent years, OP-FTIR manufacturers have developed smaller instruments that are  substantially lighter
than the OP-FTIR instrumentation used in the current project. The disadvantages of these instruments are
that the detection limits are generally higher, and the optical range of the instruments is shorter, which would
not allow the instrument to scan over beam paths greater than 100 to 200 meters. However, the smaller OP-
FTIR instruments may be ideal for certain field applications.

Another disadvantage of the OP-FTIR is the need for liquid nitrogen to cool the instrument detector. During
the long-term evaluation project, it was necessary to add liquid nitrogen to the OP-FTIR instruments at the
beginning of every day of data collection. For projects requiring 24 hour data collection, it would be
necessary to add liquid nitrogen to the instrument approximately every 12 hours. Although filling the
                                                                                                      17

-------
instrument does not require a large amount of effort, it does add some extra cost to the field operations. It
should be noted that large liquid nitrogen dewars are commercially available for use with OP-FTIR
instrumentation. The dewars can be filled with liquid nitrogen, and are capable of automatically providing
liquid nitrogen to the OP-FTIR for long periods of time. Although the large dewars are ideal for projects with
permanent deployment locations, the large dewars are not an option for field campaigns with multiple
configurations and survey areas.

Post-field analysis of the OP-FTIR data is currently recommended to quantify path-integrated
concentrations. However, with the development of quantification software such as Non-Lin and
IMACCQuant, this process does not require a Spectroscopist. Recent advancements such as real-time
IMACCQuant and ARCADIS Real-Time RPM Software (discussed in Sections 5) have made it possible to
quantify real-time concentrations in the field,  but the performance of this software is still being evaluated by
EPA and ARCADIS. Section 6 of this report presents a comparison of concentration determinations made
with real-time and post-field analyses.

3.3.2  Evaluation of OP-TDLAS Instrumentation

The project team used OP-TDLAS instruments during the Fort Collins, Colorado Springs, and Orange Co.
measurement campaigns to collect path-integrated methane concentration data. The long-term project
evaluated two OP-TDLAS instruments (Unisearch, Inc. and Boreal, Inc.). The Unisearch OP-TDLAS
instrument used up to 8 stationary telescopes, each aligned on  up to 8 mirrors. The Boreal OP-TDLAS was
mounted to a scanner and collected data along 5 beam paths.

The major advantages of the OP-TDLAS instruments are that they are lightweight, can be easily deployed
by one person, and operate at ambient, rather than cryogenic, temperatures. The mirrors needed for OP-
TDLAS measurements are also smaller and more lightweight than  the mirrors traditionally used with OP-
FTIR measurements. Another advantage of the OP-TDLAS is that  it generates real-time, path-averaged
concentration data in the field, without the need for post-field data analysis.

One disadvantage of the Unisearch OP-TDLAS used in the long-term study is  that the instrument cannot be
mounted to a scanner. The instrument consists of a control box (that houses the laser and a multiple
channel detection device) and 8 stationary telescopes. Each telescope must be connected to the control box
with fiber optic cables. Depending  on the topography and location of physical barriers at the survey area, the
distance between the control box and the telescopes may require a large amount of fiberoptic cable, which
can be difficult to deploy. The Boreal OP-TDLAS instrument used in the long-term study is mounted on a
scanner, and was much easier to deploy.
                                                                                                      18

-------
Another disadvantage of the OP-TDLAS instruments is that they are not capable of measuring multiple
compounds from the same dataset. Although OP-TDLAS instruments can detect many compounds (such as
methane, CO, CO2, NOX, and NH3), it is necessary to employ separate lasers for analysis of multiple gases.

3.3.3  Evaluation of UV-DOAS Instrumentation

A UV-DOAS instrument was used during the Fort Collins and Colorado Springs measurement campaigns to
collect path-integrated concentrations of benzene, toluene, and xylenes (BTX). The long-term project
evaluated one UV-DOAS instrument (OPSIS, Inc.). The OPSIS UV-DOAS instrument was operated in a
bistatic configuration, where the source and detector were deployed at separate ends of a single beam path,
along the surface of the survey area.

During the Fort Collins field campaign, a representative of OPSIS, Inc. assisted in deployment of the
instrument. Alignment of the instrument was difficult and took a couple of hours to complete, but data was
collected. The OPSIS, Inc. representative was not present during the Colorado Springs field campaign.
Subsequently, field personnel had difficulty in aligning the instrument, and were unable to make the
instrument operational. However, this may have been due to the fact that the field crew did not have
previous experience in operating the instrument.

The major advantage of the UV-DOAS instrument is the ability to detect the BTX compounds at low
concentrations. The UV-DOAS detected benzene, toluene, and p-xylene during the Fort Collins
measurement campaign at levels less than 5 ppb. The OP-TDLAS instrument cannot detect the BTX
compounds, and although the OP-FTIR is capable of detecting the BTX compounds, the minimum detection
level of the UV-DOAS instrument is much lower than the OP-FTIR. Another advantage of the UV-DOAS
instrument is that it does not require liquid nitrogen for operation.

One disadvantage of the UV-DOAS instrument used in  the long-term study is that it required post-analysis of
the data collected. The data analysis was performed by a representative of OPSIS, Inc. However, a spectral
validation of the detected compounds was not provided, which is recommended for any future studies
performed using this instrument.

3.3.4  Comparison of Methane Data Collected with the IMACC OP-FTIR and Unisearch OP-TDLAS Instruments

During the Fort Collins measurement campaign, the OP-FTIR and Unisearch OP-TDLAS instruments were
deployed to measure path-integrated  methane concentrations. The configurations used by the Unisearch
OP-TDLAS were often similar to the configurations used with the OP-FTIR instruments. A comparison of the
methane measurements from the two instruments was  performed (Modrak et a/., 2005a). Table 5 presents
the average methane concentrations (in ppm) measured with the OP-TDLAS and OP-FTIR along similar
beam paths during the measurement campaign. Figure 11 shows a scatter diagram of the same dataset.
                                                                                                   19

-------
Table 5.    Comparison of methane concentrations (in ppm) measured with the OP-TDLAS and OP-FTIR
           instruments
Mirror
Number
1
2
3
4
5
6
7
8

Avg.
Std. Dev.
Avg.
Std. Dev.
Avg.
Std. Dev.
Avg.
Std. Dev.
Avg.
Std. Dev.
Avg.
Std. Dev.
Avg.
Std. Dev.
Avg.
Std. Dev.
Area A 9/8/03
Vertical
OP-
TDLAS
1.91
0.02
1.99
0.08
2.08
0.05
2.05
0.04
2.06
0.05
2.09
0.03
2.09
0.02
2.06
0.02
OP-
FTIR
1.92
0.03
1.88
0.03
1.84
0.02
1.85
0.03
1.84
0.02



Area A 9/9/03
Horizontal
OP-
TDLAS
1.94
0.02
1.96
0.01
1.98
0.01
1.95
0.02
1.98
0.03
1.99
0.02
2.01
0.02
1.96
0.02
OP-
FTIR

1.78
0.01
1.78
0.01
1.77
0.02
1.79
0.02



Area A 9/9/03
Vertical
OP-
TDLAS
1.96
0.05
1.83
0.12
2.03
0.05
2.03
0.05
2.03
0.04
2.07
0.06
2.04
0.05
2.04
0.04
OP-
FTIR
1.74
0.04
1.88
0.04
1.86
0.04
1.88
0.05
1.87
0.04



Area B
OP-
TDLAS
2.01
0.04
2.03
0.05
2.06
0.05
2.03
0.04
1.98
0.03
2.05
0.02
2.02
0.02
2.07
0.02
OP-
FTIR
1.81
0.01

1.81
0.02

1.82
0.02

1.81
0.02

Area D
OP-
TDLAS
2.03
0.12
1.93
0.18
1.90
0.24
1.98
0.12
1.94
0.12
1.95
0.15
1.99
0.13
1.97
0.15
OP-
FTIR
1.80
0.02
1.77
0.02
1.75
0.02
1.75
0.02
1.73
0.02
1.72
0.02
1.73
0.02
1.71
0.02
                                                                                                  20

-------
      1.95
      1.65
          1.8
1.85
 1.9           1.95           2
OP-TDLAS Methane Cone, (ppm)
2.05
2.1
Figure 11.   Comparison of methane concentrations measured along similar beam paths during the Fort Collins
           measurement campaign with the OP-FTIR and OP-TDLAS instruments
The methane concentrations measured by the two instruments were comparable, although the
concentrations measured with the OP-TDLAS system were almost always slightly higher than
concentrations measured with the OP-FTIR instrument along similar optical paths.

These results are consistent with the results of another experiment conducted (as part of a separate project)
to compare methane measurements from the two instruments [Thoma et al., 2005]. During this experiment,
the two instruments were deployed side-by-side and aligned to an identical mirror. Methane concentration
data were collected with each instrument for a period of 30 minutes. The results of the experiment found that
methane concentrations measured with the OP-TDLAS were slightly higher (3%) than concentrations
measured with the OP-FTIR instrument.
                                                                                                     21

-------
The results of these comparisons are significant because they show that methane concentration data
collected with the two instruments are comparable, and the two instruments can be used interchangeably in
RPM configurations.
                                                                                                     22

-------
                            4.  Summary of Project Field Campaigns

As mentioned previously, the long-term evaluation study consisted of four field campaigns. The following
subsections present a summary of the findings from the first three field campaigns, as well as difficulties that
were encountered (the Orange County field campaign is discussed in Section 5, and Appendix B of this
document). It should be noted that the concentration values reported from the Fort Collins and Colorado
Springs field campaigns have not been corrected to standard atmospheric conditions.

The Somersworth, NH field campaign was conducted  in October 2002 at a Superfund site being considered
for re-use as a recreational facility. The study employed OP- FTIR instruments to perform surveys using the
HRPM and VRPM methods. Figure 12 shows the surface methane concentration contour map of the entire
landfill and located sub areas of high methane emissions (up to 6.5 ppm average methane concentration
above the global background). The most intense methane hot spot detected was in the vicinity of a hole dug
to install a  utility pole which was never installed.
Figure 12.   Surface methane concentration contours (in ppmv) overlaid on the map of the Somersworth
           Superfund Landfill
The VRPM survey found a methane flux of 5.8 grams per second from the site. Figure 13 presents the
reconstructed methane plume map from the survey.
                                                                                                     23

-------
                                       60    60    100     120    140    160    190
                                           Crosswind Distance pneters)
           Figure 13. Reconstructed methane plume map from the VRPM survey of the Somersworth site
           (concentrations shown in ppmv). The location of the vertical structure is shown by the solid black
           vertical line. The scanning ORS instrument is located in the bottom left-hand corner of the figure
The Fort Collins, CO field campaign was conducted in September 2003 at a former landfill site currently
comprised of a commercial area, park, and playgrounds. The city of Fort Collins is interested in developing a
larger recreational area at the site, and requested assistance from EPA to perform an assessment of gas
emissions at the site. The study used OP-FTIR, OP-TDLAS, and UV-DOAS instruments.

HRPM surveys of the site did not detect the presence of any methane hot spots, and methane surface
concentrations at the site were essentially at ambient background levels. However, the HRPM survey
detected a gasoline hot spot (average concentration over 81 ppb, maximum concentration about 100 ppb) in
the vicinity of a large playground at the site.
                                                                                                      24

-------
A VRPM survey was performed to measure fluxes of fugitive emissions. The survey consisted of two VRPM
configurations, located on the upwind and downwind sides of the survey area. The VRPM survey detected
methane, ammonia, and gasoline in the downwind configuration, along the fence line of the site. The
measured concentrations of methane and ammonia correlated well temporally, suggesting the source of the
methane and ammonia emissions may be the same. However, the lack of methane and ammonia
concentrations measured during the HRPM survey suggested that the survey area was not a significant
source of methane emissions. By looking at data on wind direction, it was concluded that the source of
ammonia and methane measured along the downwind VRPM configuration may have been from a source
located outside of the site, northeast of the survey area (across the river). Figure 14 shows the surface
gasoline concentration contour map generated from the HRPM survey, as well as the suspected source
location of the measured methane and ammonia. The identification of the gasoline hot spot is significant
because it demonstrates the capability of the ORS instrumentation (with the RPM method) to detect
emissions hot spots of compounds (other than methane) from ground-based sources at relatively low
concentrations.
                                    hJ
                             fccrt j» tw t*
                                uoumwmd
                            Configure! on
           Figure 14.  Summary map from the Fort Collins, CO site showing the surface gasoline
           concentration contour map (concentration shown in ppbv), and suspected source location
           of the measured methane and ammonia
                                                                                                    25

-------
The UV-DOAS instrument was deployed at the site to collect data concurrently with the OP-FTIR instrument.
The UV-DOAS detected the presence benzene, toluene, and p-Xylene. The average measured
concentrations of benzene, toluene, and p-Xylene were 2.6 ppb, 21 ppb, and 4.9 ppb, respectively. The
concentrations of toluene measured with the UV-DOAS instrument correlated well with gasoline
concentrations measured with the OP-FTIR instrument during the same time period indicating that the
gasoline plume contains BTX compounds at levels lower than the MDL of the OP-FTIR instrument.

The Colorado Springs, CO field campaign was conducted in September 2003 at a former landfill site as part
of an effort to rehabilitate the site for recreational use. The current owners of the landfill and the State of
Colorado requested assistance from EPA to perform a site assessment to search for the presence of any
fugitive gas emissions from the site. The study used OP-FTIR, OP-TDLAS, and UV-DOAS instruments.

HRPM surveys of the site detected the presence of two methane hot spots  located along the eastern side of
the site (see Figure 15).
                                                 fUU
                Figure 15.  Surface methane concentration contours (in ppmv) overlaid on the
                          map of the Colorado Springs, CO site. The figure shows the location
                          of the VRPM configuration at the site
                                                                                                     26

-------
The first methane hot spot, located in the Northeast quadrant, had concentrations greater than 0.4 ppm
above an ambient background concentration of 1.55 ppm. The other hot spot was located in the Southeast
quadrant, and had concentrations greater than 0.5 ppm above ambient background levels.

The VRPM configuration was set up along the northern boundary of the site (see Figure 16). The calculated
methane flux from the site was 4.9 g/s. The peak of the methane plume measured during the VRPM survey
was located close to the location of the OP-FTIR/scanner. This agrees well with the location of the methane
hot spots detected during the HRPM survey, indicating that the hot spots may be a major source of the
methane plume detected during the VRPM survey. The location of the vertical structure is shown by the solid
black vertical line. The scanning ORS instrument is located in the bottom left-hand corner of the figure.
                                                          ef5]
           Figure 16.  Reconstructed methane plume map from the VRPM survey of the Colorado Springs,
                     CO site (concentrations shown in ppmv). The location of the vertical structure is
                     shown by the solid black vertical line. The scanning ORS instrument is located in
                     the bottom left-hand corner of the figure
The OP-TDLAS system collected information on methane concentrations along the surface of the site and
on a slope adjacent to the southern boundary of the site. The survey of the surface found average methane
                                                                                                      27

-------
concentrations between 0.47 ppm and 0.53 ppm above ambient background levels. These values agree
fairly well with the methane levels found in hot spots identified during the HRPM surveys.

The survey of the slope along the southern boundary of the site found slightly elevated methane
concentrations. The largest average measured methane concentration was 1.34 ppm above ambient
background levels.

4.1  Difficulties in the Application of the RPM Method at Landfill Sites

Over the course of the long-term evaluation study, the project encountered some difficulties in applying the
RPM methods at the measurement sites. The difficulties were primarily due to the topography and physical
barriers of the site,and unfavorable wind directions. The following sections present a discussion of these
difficulties, and guidance for addressing them.

4.1.1   Sites with Elevated Passive Vents

The Colorado Springs measurement site had several passive vents installed over the surface  of the landfill
area. The passive vents were located approximately 2 meters above the surface of the site (see Figure 17).
During the HRPM survey of this site, these vents were sealed with  plastic because they were suspected
methane emissions hot spots, and may have  masked other emissions hot spots located  along the surface of
the site. The seals were removed from the vents for the VRPM survey. However, after reviewing the
experimental design for this measurement campaign, this may not  have been the best approach for
characterizing the surface emissions from this site. The elevated vents are obvious potential surface
emissions hot spots. However, the HRPM surveys are used to present a true representation of actual
surface emissions from the site, and sealing the vents with plastic during the HRPM surveys may alter the
magnitude and spatial representation of actual surface emissions from the site.
                                                                                                       28

-------
                 Figure 17. Passive vents sealed with plastic at the Colorado Springs site
4.1.2  Measurement of Methane Emissions from Slopes of Sites

The topography of many landfill or former landfill sites consists of a large elevated mound with a flat surface
on the top and steep slopes on the sides. The topography of the Colorado Springs site was configured in this
manner. The RPM measurements conducted during this measurement campaign were done on the flat
surface of the site. Since it was not possible to deploy conventional RPM configurations on the side slopes,
the concern is that methane emissions from the slopes were not completely quantified.

As part of the Colorado Springs measurement  campaign, the Unisearch OP-TDLAS instrument was
deployed along the southern slope of the site. Path-averaged methane concentration data were collected
along 8 beam paths. Figure 18 presents a schematic of the configuration. The circles indicate the location of
the OP-TDLAS telescopes, the squares indicate the location of the mirrors, and the solid black lines indicate
the location of the beam paths.
                                                                                                       29

-------
                                          Landfill top surface
                          SWComra-rfSHc
                                                                SRComtrof Sht
                                                           SLOP!
                                                                 ii 1 it
Figure 18.   Schematic of the OP-TDLAS configuration deployed along the southern slope of the Colorado
           Springs site
The survey detected elevated methane along beam path #2 (1.07 ppm above background) and beam path
#7 (1.34 ppm above background). Additionally, the study found large standard deviations in the methane
concentrations data, suggesting that methane hot spots were present along the slope. However, since a
conventional HRPM survey was not conducted along the slope, it was not possible to locate or quantify
methane hot spots.

It is recommended that future measurement campaigns at sites with sloped topography include an HRPM
survey of the slope areas to locate and quantify methane hot spots. However, HRPM surveys may be
difficult to conduct if the site slopes are steep, especially when using the OP-FTIR instrument, because the
scanner cart requires a relatively level surface for safe deployment. This may not be possible along the side
slopes. The Unisearch  OP-TDLAS instrument may be a better instrument to conduct slope surveys because
it is lightweight, easier to deploy than the OP-FTIR, and does not require a  level surface for deployment.

If sufficient instrumentation and project resources are available, the alternative VRPM approach (described
in Section  2.4 of this document) can be applied to directly characterize methane emissions from the slopes
of the landfill cell.
                                                                                                     30

-------
4.1.3  Capture of Emissions from Hot Spots Located a Large Distance Upwind of the VRPM Configuration

During some of the measurement campaigns (Somersworth, Colorado Springs), a single VRPM
configuration was deployed along one side of the survey area to measure the methane flux from the entire
site. As mentioned in Section 2, the VRPM configuration is deployed so that the plane of the configuration is
as close to perpendicular to the prevailing wind direction as possible, to ensure that the maximum amount of
emissions from the site are captured by the configuration.  However, during  some of the VRPM surveys, the
winds were not exactly perpendicular to the configuration because the prevailing wind direction shifted
slightly after the configuration was deployed, or the possible locations for the VRPM configurations were
limited due to barriers at the site.  The concern is that in cases where the prevailing winds are not close to
perpendicular to the VRPM plane, emissions from all of the surface hot spots may not be captured
completely by the VRPM configuration, leading to an underestimation of the flux value from the site.  This is
an even larger concern for hot spots located a large distance upwind of the VRPM configuration.

During the long-term evaluation project, the VRPM configurations were deployed so that the length of the
configuration was as long as possible to increase the chances of capturing  all of the emissions from  the
survey area. In fact, whenever possible, the VRPM configuration should be extended beyond the boundaries
of the survey area.

The development of the Real-Time RPM software (discussed in Section 5 of this document) is a major
advancement in the application of the RPM method. The software is capable of providing real-time surface
concentration maps in the field. This is  extremely valuable in assuring that emissions  from major emissions
hot spots are captured by the VRPM configuration, because the VRPM configuration  can be setup directly
downwind of the hot spot locations, if necessary.

As part of the effort to assess the ability of the VRPM method to capture emissions from hot spots located a
large distance upwind of the  configuration, ARCADIS and  EPA conducted a validation study in June and
July 2006 using tracer gas releases. The objective of the study was to provide guidance towards the
development of procedures for ensuring the complete capture of emissions by the VRPM method. The
results of the study are presented in Section 6 of this document.

4.1.4  Prevailing Wind Direction During the Time of the Measurements

As mentioned in Section 2 of this document, the VRPM method configuration should be set up downwind of
the survey area so that the prevailing wind direction is as close to perpendicular to the plane of the
configuration as possible This is necessary to ensure that  the VRPM configuration is capturing as much of
the emissions plume from the survey area as  possible. When using the HRPM method, there is no need to
consider prevailing wind direction.
                                                                                                      31

-------
During the Colorado Springs field campaign, the project team deployed the VRPM configuration in the
morning on the last day of the campaign. The configuration was originally deployed along the eastern
boundary of the site, as the forecasted wind direction was from the west. However, after the configuration
was deployed, the project team observed that the prevailing winds were from the south. Since this occurred
on the last day of the field campaign, the project team decided to re-deploy the VRPM configuration along
the northern boundary of the site, in  order to capture emissions from the landfill cell.

When applying the VRPM configuration, the project team decides where to deploy the configurations based
on forecasted wind directions. However, the actual observed wind direction is not always the same as the
forecasted direction. This can be problematic when conducting a project involving multiple configurations
with limited project resources. When applying the VRPM configuration,  it is recommended to deploy the
configuration in one location for the longest time period possible, to account for periods of varying wind
conditions.

If sufficient instrumentation  and project resources are available, the alternative VRPM approach (described
in Section 2.4 of this document) can be applied to characterize emissions from the survey area and slopes,
as well as areas upwind of the landfill cell. Because the alternative VRPM approach employs four VRPM
measurement planes that totally encompass the survey area, flux measurements can be collected from the
area of interest, regardless  of the prevailing wind direction during the time of the measurements.
                                                                                                       32

-------
                             5.  Orange County, NC Field Campaign

ARCADIS and EPA conducted a fugitive emissions measurement campaign during May 2005 at the Orange
County Municipal Landfill located near Chapel Hill, North Carolina using OP-FTIR and OP-TDLAS
instruments. The measurement campaign also served as a demonstration of optical remote sensing
technologies and the RPM method. The following section presents background information on the site, the
experimental setup used during the campaign, a discussion of how difficulties encountered in previous
campaigns were addressed during this campaign, and details on the Real-Time RPM software, which was
deployed for the first time during this field campaign. The results of this study can be found in Appendix B of
this document.

5.1  Site Information

The project team conducted measurements in the active and closed landfill areas at the site  to compare
levels of fugitive emissions from different landfill areas. Figure 19 presents an overview of the site.
                                          Closed Landfill Site
                                             (50 acres)
                                                       --'
                                         Active Subtitle D  / i
                                           Landfill Site
                                            (26 acres)
Figure 19. Site map of the Orange County Municipal Landfill site showing the location of the two landfill areas
                                                                                                      33

-------
The Orange County Municipal Landfill site is located on 200 acres of land. The closed landfill site is located
on the northern portion of the site, and has a footprint of 50 acres. The area began accepting waste in 1972,
and operated until 1995 when the new Subtitle D Landfill (active site) was ready to accept waste.
Approximately 810,000 tons of waste was landfilled during the 23 years that the closed landfill site was in
operation. The area accepted municipal solid waste, construction and demolition waste, and yard waste.
The Closed Landfill Site was capped with three feet of soil in 1995 and 1996, and 45 elevated, passive gas
vents were installed in 1998. Figure 20 shows a picture of the closed landfill site.
           Figure 20. Closed landfill site at the Orange County Municipal Landfill
The active landfill Site is a 26-acre Subtitle D landfill that opened on July 1, 1995. Leachate is injected into
the waste, and is collected in a lined lagoon at the site. The active landfill site has a capacity of 880,000 tons
of waste. As of June 2004, approximately 524,645 tons of waste had been landfilled. Figure 21 shows a
picture of the active landfill site.
                                                                                                          34

-------
             Figure 21. Active landfill site at the Orange County Municipal Landfill
5.2  Project Objectives

The objectives of the study were as follows:

•   Collect OP-FTIR and OP-TDLAS data in order to identify major emissions hot spots by generating
    surface concentration maps in the horizontal plane using the HRPM method

•   Measure emission fluxes of detectable compounds downwind from major hot spots using the VRPM
    method

•   Demonstrate the operation and function of the ORS technologies

5.3  Testing Procedures

The following subsections describe the testing procedures used in the Active and Closed Sites of the landfill
facility (refer to Figure 19 for the geographical orientation of each area). The actual survey areas within the
two sites were chosen to ensure that the study investigated the maximum amount of surface area at the
sites.  One factor that affected the location of the survey areas was the topography of each site, and the
                                                                                                       35

-------
location of the work face within the active site. HRPM surveys were performed in each site (using an IMACC
OP-FTIR) to produce surface methane concentration maps and to locate any surface hot spots. The project
team performed VRPM surveys at both sites to obtain an estimated emission flux rate of methane. VRPM
surveys were done in the active site using an IMACC OP-FTIR and Boreal OP-TDLAS. VRPM surveys were
done in the  closed site using an IMACC OP-FTIR and Unisearch OP-TDLAS.

OP-FTIR data were collected as interferograms. Concentrations were determined in real-time in the field,
using the Real-Time RPM software. The software package uses IMACCQuant for concentration
determination. The concentration data are then input into the RPM algorithms to produce surface
concentration contour maps and downwind plume maps in the field.

In order to evaluate the performance of the IMACCQuant software (used by the Real-Time RPM software),
the raw OP-FTIR data (interferograms) were archived to CD-ROM, and a post-field analysis of the data was
done using  Non-Lin (Spectrosoft) quantification software and the IMACCQuant software. A comparison of
the results of the two analysis methods is presented later in this section.

The OP-TDLAS concentration data are provided  as a real-time output by the instrumentation. The
concentration data from the Boreal OP-TDLAS instrument was input to the Real-Time RPM software to
provide downwind plume maps in  the field. The concentration data from the Unisearch OP-TDLAS
instrument was input to the RPM software after the field campaign to produce downwind plume maps.

Meteorological data including wind direction, wind speed, temperature, relative humidity, and barometric
pressure were continuously collected during the measurement campaign. Two RM Young meteorological
instruments were deployed in the Active Site, and two Climatronics meteorological instruments were
deployed in the closed site. Both models are automated, collect real-time data, and record the data as one-
minute averages to the computer used for data collection. Wind direction and speed-sensing heads were
used during the VRPM surveys to collect data at two heights, 2 and 10 meters (the 10 meter sensor was
placed on top of the scissorsjack).

5.4  Active Site

5.4.1   HRPM Measurements

The project  team conducted HRPM surveys in two survey areas within the active site (see Figure 22).
                                                                                                    36

-------
Figure 22.   Map of the active site showing the location of the survey areas and prevailing wind direction during
           the time of the surveys
An HRPM survey was conducted in Survey Area #1 on May 2, 2005 using an IMACC OP-FTIR. The
instrument was located in the southwestern corner of the survey area.

HRPM surveys were conducted in Survey Area #2 on May 3-5 using an IMACC OP-FTIR. During each
survey, the OP-FTIR instrument was located in the southeastern corner of the survey area. The May 3
HRPM survey consisted of nine optical paths and the May 4-5 surveys consisted of twelve optical paths.

5.4.2  VRPM Measurements

VRPM surveys were not conducted in Survey Area #1 due to the close proximity of the area to the work face
of the Active Site. On May 4, two separate VRPM surveys were conducted in Survey Area #2 using the
IMACC OP-FTIR and the Boreal OP-TDLAS, respectively. On May 5, one VRPM survey was conducted
using the Boreal OP-TDLAS instrument. The prevailing wind direction during the surveys was from the
northeast. The VRPM  configurations were deployed along the southern boundary of Survey Area #2, and
consisted of five retro-reflecting mirrors; two deployed along the surface between the ORS instrument and
                                                                                                   37

-------
the vertical tower, one mounted half-way up the vertical tower, one mounted at the top of the vertical tower,
and one along the surface approximately 30 meters beyond the vertical tower. Table 6 presents a summary
of the VRPM survey results from the active site.
       Table 6.  Summary of methane flux values measured during the VRPM surveys in the active site
Date
May 4, 2005
May 4, 2005
May 5, 2005
Instrument Used
IMACC OP-FTIR
Boreal OP-TDLAS
Boreal OP-TDLAS
Average Methane
Flux Value
(grams per second)
10
7.4
7.3
Range of Methane
Flux Values
(grams per second)
4.2 to 17
2.0 to 16
1.0 to 24
5.5  Closed Site

5.5.1  HRPM Measurements

The project team conducted HRPM surveys in two survey areas within the closed site (see Figure 23).

An HRPM survey was conducted in Survey Area #1 on May 2 using an IMACC OP-FTIR. The instrument
was located in the northeastern corner of the survey area.

HRPM surveys were conducted in Survey Area #2 on May 3 and May 5 using an IMACC OP-FTIR. The May
3 survey used twelve optical paths, and the May 5 survey used nine optical paths. The instrument was
located in the northwestern corner of the survey area during both surveys.

5.5.2  VRPM Measurements

VRPM measurements were conducted in the closed site using the IMACC OP-FTIR and Unisearch OP-
TDLAS instruments. The locations of the VRPM configurations are shown in Figure 23. The yellow circle
indicates the locations of the Unisearch OP-TDLAS instrument, and the red circle indicates the location of
the OP-FTIR instrument. The black square denotes the location of the vertical tower during each survey.
                                                                                                   38

-------
                          Prevailing
                           Wind
                         Direction on
                          May 3rd
Figure 23.   Map of the closed site showing the location of the survey areas and prevailing wind directions
           during the time of the surveys
On May 3, VRPM surveys were conducted along the eastern side of Survey Area #2 (measuring emissions
from both survey areas). During this day, the prevailing wind direction was from the west. The OP-FTIR
VRPM configuration consisted of six retro-reflecting mirrors; three deployed along the surface between the
ORS instrument and the vertical tower, one mounted half-way up the vertical tower, one mounted at the top
of the vertical tower, and one along the surface approximately 25 meters beyond the vertical tower. The OP-
TDLAS VRPM configuration consisted of five retro-reflecting mirrors; three deployed along the surface
between the ORS instrument and the vertical tower, one mounted half-way up the vertical tower, and one
mounted at the top of the vertical tower.

On May 4, a VRPM survey was conducted along the southern side of the closed site (measuring emissions
from both survey areas). During this day, the prevailing wind direction was from the northeast. The VRPM
                                                                                                       39

-------
configuration consisted of seven retro-reflecting mirrors; three deployed along the surface between the ORS
instrument and the vertical tower, one mounted half-way up the vertical tower, one mounted at the top of the
vertical tower, and two along the surface beyond the vertical tower. Table 7 presents a summary of the
VRPM survey results from the closed site.
      Table 7. Summary of methane flux values measured during the VRPM surveys in the closed site
Date
May 3, 2005
May 3, 2005
May 4, 2005
Instrument Used
IMACC OP-FTIR
Unisearch OP-TDLAS
Unisearch OP-TDLAS
Average Methane
Flux Value
(grams per second)
22
10
12
Range of Methane
Flux Values
(grams per second)
5.4 to 58
2.1 to 28
2.0 to 55
5.6  Addressing Potential Difficulties with Applying the RPM Method to the Site

The Orange County Landfill site presented a couple of the same difficulties in applying the RPM method
experienced during previous field campaigns (see Section 4). The closed site at the landfill had many
elevated passive vents, located approximately 2 meters above the surface of the site. Although it was
obvious that the passive vents were probably methane emissions hot spots, the vents were not covered
during the HRPM surveys. Although the results of the HRPM surveys (see Figures B8, B9, and B10 of
Appendix B) conducted in the closed site found hot spots located in the vicinity of some of the vents, the
generated surface concentration contour maps provide a true picture of the surface methane emissions from
the area.

Another issue was the concern of capturing emissions from surface hot spots located a large distance
upwind of the VRPM configurations. This was not a concern during the VRPM surveys done in the active
site, due to the relatively small dimensions of the survey area (approximately 80 meters by 60 meters).
However, this issue was a concern during the VRPM surveys of the closed site, due to the large dimensions
of the survey area. In  response to this concern, the VRPM configurations used in the closed site were
extended as far as possible horizontally, given the topography of the site. Each of the VRPM configurations
used in the closed site were extended more than 200 meters horizontally, to maximize the chances of
capturing emissions from surface hot spots located upwind of the configuration.

5.7  Development of Real-Time Analysis Capabilities

One of the major advancements in the RPM  method has been the development of real-time software
capabilities. The Orange County Municipal Landfill measurement campaign represents the first time that
                                                                                                      40

-------
Real-Time RPM software has been used in the field. The real-time software package for the OP-FTIR
instrumentation uses IMACCQuant for real-time concentration determination of multiple compounds. The
concentration data are then input into the RPM algorithms to produce surface concentration contour maps,
plume maps, and flux determinations, in real-time, in the field.

The Real-Time RPM software was also used with the Boreal OP-TDLAS instrument. The real-time methane
concentration values determined by the instrument are input into the RPM algorithms to create the real-time
RPM maps.

The real-time software is particularly useful in the field because  it can be used as guidance in selecting the
location of the VRPM configurations to ensure the best chance of capturing emissions from major surface
emissions hot spots.

Although the real-time concentration software was used during the Orange County Municipal Landfill
campaign, Non-Lin quantification software was used to perform a post-field analysis of the OP-FTIR
concentration data from the field campaign. This concentration data was then input into the RPM software to
produce the OP-FTIR results presented in Appendix B of this report.
                                                                                                     41

-------
                            6.   VRPM Plume Capture Validation Study
6.1  Background Information and Study Objectives

In order to assess the ability of the VRPM method to capture emissions from hot spots located a large
distance upwind of the configuration, ARCADIS and EPA conducted a VRPM plume capture validation study
during June and July 2006 at the Orange County Municipal Landfill. The study, which used tracer gas
releases to determine plume capture by the VRPM method, was conducted in the closed area of the landfill
facility (see Figures 18 and 19).

The study used two scanning Open-Path Fourier Transform Infrared (OP-FTIR) spectrometers and was
conducted to evaluate the effectiveness of the vertical radial plume mapping (VRPM) method in capturing
plumes from tracer gas releases located at different distances upwind of the measurement configuration.
The effectiveness of the measurement configuration in capturing plumes (in the horizontal and vertical
direction) was evaluated by comparing the actual release rate of tracer gases (deployed at different
distances upwind of the configuration) to the flux values recovered by the measurement configurations.

The primary objective of the study was to develop guidance for applying the VRPM method to studies
charactering fugitive emissions from area sources. The guidance will include:

•   Configuration  length necessary for complete plume capture

•   Maximum upwind plume source location for which the VRPM method accurately characterizes emission
    rates

The secondary objective of the study was to characterize emissions of methane from the Closed Area of the
landfill. This data was considered non-critical for this study, and was collected to provide further information
on methane emissions from landfill sites. The methane flux data (collected along the longest VRPM
configuration) from this study can be found in Appendix C of this report.

6.2  Testing Procedures

The experimental setup consisted of two VRPM configurations, co-located in a parallel manner, sharing  one
vertical structure (scissor lift). The orientation of the configurations was determined for each day based on
the forecasted wind direction. The two configurations were oriented so that the prevailing wind direction was
as close to perpendicular to the plane of the configurations as possible. The horizontal length of the first
configuration was  approximately one-third the length of the second configuration. The length of the first
configuration was  approximately 60 meters, and the length of the second configuration was approximately
                                                                                                       42

-------
200 meters. The configuration lengths deviated from the original project Quality Assurance Project Plan
which stated that the length of the two configurations would be 100 and 300 meters, respectively. These
lengths were not possible due to the topography of the site.

The first configuration consisted of five retro-reflecting mirrors; two located on the surface between the OP-
FTIR instrument and the scissor lift, one at the base  of the scissor lift, one mounted at a point half-way up
the scissor lift, and one mounted at the top of the scissor lift. The second configuration consisted of five
retro-reflecting mirrors; one located on the ground between the OP-FTIR and the scissor lift, one at the base
of the scissor lift, one mounted at a point half-way up the scissor lift, one mounted at the top of the scissor
lift, and one located  along the ground approximately  75 meters beyond the location of the scissor lift. Figure
24 presents a schematic of the two VRPM configurations used for the study.
      Figure 24. Schematic of the experimental configuration used for the VRPM validation study
The data was collected using two OP-FTIR spectrometers, each mounted on a commercially available
scanner manufactured by Orbit, Ltd. The scanner is used to maneuver the instrument in the horizontal and
vertical planes, and is typically used for operating equipment used for military applications. Although the
QAPP called for collecting data along the first configuration using a IMACC, Inc. OP-FTIR, this was not
possible due to an instrument malfunction during the first day of the project. As an alternative, data was
collected along the first configuration using a AIL, Inc. OP-FTIR. Data was collected along the second
configuration using a second IMACC, Inc. OP-FTIR.
                                                                                                        43

-------
Two tracer gases were released simultaneously during the study, sulfur hexafluoride (SF6) and acetylene
(C2H2). The tracer gases were released through soaker hoses which were deployed along the ground
upwind of the VRPM configuration. The hoses each had a crosswind dimension of approximately 50 meters
long.

The acetylene release was located approximately 20 meters upwind from the VRPM configurations, and
remained in this position throughout the measurement campaign, to provide a "ground truth" measurement,
or calibration for the sulfur hexafluoride plume capture measurements. The SF6 was released from four
different upwind locations to allow for the evaluation of the vertical plume capture capabilities of the VRPM
method. Plumes released a greater distance upwind of the VRPM configuration will be more vertically
developed due to atmospheric dispersion, and it was necessary to release a tracer gas at different upwind
locations to determine the  maximum upwind distance that the VRPM method is able to sufficiently capture
the  whole plume. The SF6 release was initially located in the same location as the acetylene, approximately
20 meters upwind from the VRPM configurations. For the second survey, the SF6 release was moved to a
location approximately 100 meters upwind of the VRPM configurations.

After the second survey was completed (with the acetylene located 20 meters upwind of the VRPM
configuration and the sulfur hexafluoride located  100 meters upwind), the SF6 concentrations measured
along the two uppermost beam paths ending at the vertical tower (of the longest VRPM configuration) were
analyzed. A statistical analysis (a t-test) was performed to compare the average SF6 concentrations
measured along each of the two beams. The t-test was done  using a sample size of n=30, with a two-sided
95% confidence interval. This analysis was done to determine the location of the two additional sulfur
hexafluoride releases. The ultimate goal was to locate the SF6 release at upwind  locations where the longest
VRPM configuration is: (1) easily capturing the SF6 plume, (2) sufficiently capturing the SF6 plume, but the
release is located at the maximum upwind distance fordoing so, and (3) not fully capturing the SF6plume.
The three possible scenarios were as follows:

1.   If there is no statistically significant difference between the average concentrations along each beam
    (i.e. no vertical concentration gradient), this indicates that the VRPM configuration is not vertically
    capturing the plume from the 100 meter upwind release point. In this case, two additional SF6 releases
    will be performed closer to the plane of the VRPM configurations, at distances of 40 and 70 meters
    upwind of the VRPM configuration.

2.   If the average difference between the average concentrations along each beam is less than 10% (i.e. a
    slight vertical concentration exists), this indicates that the VRPM configuration is sufficiently vertically
    capturing the plume from the 100 meter upwind release point, but the release is located close to the
    maximum upwind distance fordoing so. In this case, two  additional SF6releases will be performed at
    distances of 60 and 140 meters upwind of the VRPM configurations.
                                                                                                      44

-------
3.  If the average difference between the average concentrations along each beam is greater than 10% (i.e.
    a substantial vertical concentration exists), this indicates that the VRPM configuration is vertically
    capturing the plume from the 100 meter upwind release point, and the 100 meter upwind location is not
    close to the maximum upwind location for complete plume capture. In this case, two additional SF6
    releases will be performed at distances of 140 and 180 meters upwind of the VRPM configuration.

The results of the t-test performed during the study after the 100 meter release was completed are
presented in Table 8.

The results indicated that when considering the calculated t-value of 3.69 and a sample size of 30, there is a
statistically significant difference between the two concentration datasets, at the 95% confidence interval.
The results also showed that the average difference between the concentrations measured along each
beam was greater than 10% (scenario #3 above). This suggests that two additional SF6 tracer releases
should  have  been located at distance of 140 and 180 meters  upwind of the VRPM  configurations. However,
due to geographical limitations at the site, the largest  possible distance upwind of the VRPM configurations
was approximately 140 meters. Due to this limitation,  the project team elected to place the two additional
SF6 tracer releases at distances of 60 and 140 meters upwind of the VRPM configurations. These two
additional locations allowed the team to collect data from a wide range of distances upwind of the
configuration. Also, the 140 and 180 meters  distance  where predicted with an 300-meter long VRPM
configurations for complete horizontal plume capture when wind direction is perpendicular to the plane. The
change in the actual long VRPM configuration merited a change in the determined  upwind distances of the
same size source.

The amount of tracer gas released was regulated using two Environics mass flowmeters, which were
calibrated  by the EPA Metrology Lab prior to the study. For this study, the mass flowmeter used for the
acetylene releases was pre-set to a flow rate of 5600  cubic centimeters per minute, or 0.110 grams per
second. The mass flowmeter used for the SF6 releases was pre-set to a flow rate of 1050 cubic centimeters
per minute, or 0.110 grams per second. Additionally, a digital  scale was used to provide  a secondary
method for confirming the release rates of the tracer gases. The digital scale was used to obtain the mass of
each gas cylinder before and after each tracer gas release. The release rate (in grams per second), was
determined by dividing the total mass of gas released during the tracer release by the total time of the
release.

Two meteorological heads were deployed to collect wind speed and wind direction  data during the study.
One head was deployed at the base of the scissor lift, at a height of approximately  2 meters. The other head
was deployed at the top of the scissor lift, at  a height of approximately 10 meters. Each survey lasted at
least two hours, or until approximately one hour of concentration data was collected during periods that the
prevailing winds were within 30 degrees of perpendicular to the longest VRPM configuration and the
prevailing wind speeds were between 1 and  8 m/s.
                                                                                                       45

-------
Table 8.    Results of the t-test performed using sulfur hexafluoride concentration data collected along
           beam path 4 and 5 during the 100-meter release
Cycle #
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30

t-value=3.69
SF6 Concentrations (in ppm) Measured
Along Beam Path #4
0.00238
0.00265
0.00284
0.00176
0.00196
0.00169
0.00212
0.00204
0.00291
0.00206
0.00145
0.00436
0.00350
0.00261
0.00151
0.00149
0.00198
0.00278
0.00431
0.00213
0.00129
0.00119
0.00165
0.00288
0.00235
0.00267
0.00254
0.00216
0.00421
0.00299
Mean=0.002415
Variance=0.0000007
SF6 Concentrations (in pm) Measured
Along Beam Path #5
0.00149
0.00157
0.00210
0.00198
0.00276
0.00086
0.00109
0.00214
0.00114
0.00188
0.00076
0.00128
0.00239
0.00121
0.00142
0.00125
0.00172
0.001 1 1
0.00135
0.00081
0.00122
0.00154
0.00070
0.00255
0.00255
0.00119
0.00314
0.00274
0.00255
0.00203
Mean= 0.001 684
Variance=0.0000005
                                                                                                           46

-------
6.3  Procedure for Plume Capture Assessment

The first step in assessing plume capture of the VRPM configurations was to compare the calculated
acetylene and sulfur hexafluoride flux values  (determined along both VRPM configurations) from the 20
meter upwind release point when both tracer gases were located side-by-side. The calculated flux values
were compared to the actual release rates for each tracer gas, yielding the recovery percentage of the
VRPM method for each tracer gas. Since the recovery percentage of each tracer gas may differ slightly due
to differences in the physical and chemical properties of the gases, it was necessary to eliminate this bias as
a variable in the data analysis. In order to eliminate this bias, the recovery percentages of each gas at the 20
meter upwind distance were ratioed along each VRPM configuration. This ratio was then used to calibrate
the sulfur hexafluoride  measurements made at the additional upwind distances, while the location of the
acetylene release remained constant throughout the study.

The acetylene recovery percentages (along both VRPM configurations) calculated from each additional
release in the study were used to adjust the corresponding sulfur hexafluoride  plume capture percentages
from each release point. This was done to confirm that the difference between  actual and calculated sulfur
hexafluoride rates was due solely to plume capture issues. Table 9 presents a  hypothetical data set from the
proposed experimental design, and an example of the calculations that were used in the assessment of
plume capture.

       Table 9.  Example dataset from the executed experimental design
Configuration
60-m VRPM
200-m VRPM
20-m Acetylene
Recovery*
94%
97%
20-m Sulfur
Hexafluoride
Recovery*
91%
95%
Release #2 (100-m)
Sulfur Hexafluoride
Recovery*
75%
80%
Release #2 (20-m)
Acetylene
Recovery*
86%
90%
       ' Recovery percentage is defined as the ratio of the flux value calculated by the VRPM method to the actual
        release rate, multiplied by 100.
In order to assess the plume capture percentage of the VRPM method (along both VRPM configurations) at
an upwind distance of 100 meters, the following steps must be taken:

The hypothetical sulfur hexafluoride recovery percentage (the recovery percentage if SF6were released at
20 meters during the same time period that it is actually released at 100 meters) is calculated to eliminate
factors other than  plume capture issues in evaluating the sulfur hexafluoride capture percentage. This is
done by proportioning the acetylene to SF6 recovery percentage found during the side-by-side 20 meter
release to the acetylene recovery percentage found during the release coinciding with the 100 meter SF6
release. The following equation shows how this is done when considering the 60-meter VRPM configuration:
                                                                                                        47

-------
                                   94% _ 86%
                                   91% ~  X

where X =   the hypothetical sulfur hexafluoride recover percentage (in this case X = 83%).

The actual sulfur hexafluoride recovery percentage found during the 100 meter gas release (75%) is then
ratioed to the value of X calculated above (83%). In this example, (75%/83%*100) is equal to 90%, which is
the captured sulfur hexafluoride release percentage that can be attributed to the issue of vertical and
horizontal plume captue plume capture. The same calculations are performed for the data collected along
the 200 meter VRPM configuration.

6.4 Results and Discussion

The release rate of the tracer gases was determined during the study by using mass flow meters to control
the release rate of the gases. The mass flow meters were set to a flow rate of 0.11 grams per second for
each gas, for the duration of the study. The original experimental design stated that in addition to the mass
flow meters, a digital scale would be used to weigh the gas cylinders before and after each release to
confirm the release rate of the gases. However, this was not possible, due to a malfunction in the digital
scale after the 20 meter release survey. The malfunction was possibly due to the extremely hot weather
during the study, or damage to the scale caused by the weight of the cylinders. The digital scale did not
function during the other gas releases performed during the field campaign.

Before this malfunction, the weight of the acetylene cylinderwas measured before and afterthe 20 meter
release. According to the measurements, the acetylene cylinder lost 0.75 kilograms of gas over a period  of
88 minutes, indicating that the actual release rate was 0.140 grams per second. This may indicate some
loses in the fittings before the inlet to the mass flow meter.

6.4.1   20-Meter Releases

The 20-meter tracer gas release survey was completed on June 16. The wind conditions during the duration
of the gas releases were light and somewhat variable. Despite the variability of the wind conditions, the initial
analysis of the wind data indicate that a sufficient amount of data had been collected during periods of
acceptable wind conditions (between the beginning of the release at approximately 10:40 a.m. and 1:00
p.m.). However, during the post-analysis phase of the  study, it was revealed that although  there were many
periods between 10:40 a.m. and 1:00 p.m. when the wind criteria were met, there was not sufficient data
during this time period to analyze the plume capture capabilities of the method. Figure 25 shows a time
series of sulfur hexafluoride fluxes calculated along the 200 meter VRPM configuration and the prevailing
wind direction, from normal to the  configuration. The negative flux values depicted in the figure indicate time
periods when the prevailing wind was from the side of the configuration opposite to the side where the tracer
                                                                                                       48

-------
gases were deployed. The figure shows that during the time period between approximately 10:40 a.m. and
1:00 p.m., there were periods when the winds were within 30 degrees of perpendicular to the VRPM
configuration. However, during this time period, there were only three calculated flux values above 0.10
grams per second. Since the 20-meter SF6 release was the closest to the VRPM configuration, one would
expect a better plume capture, with calculated flux values around 0.11 grams per second (the pre-set mass
flow meter release rate). Based on this, and a comparison of the calculated SF6 fluxes found from the other
release  points, the data from the 20-meter release was determined to be insufficient due to the very light and
variable wind conditions during the time of the releases.

Due to these results, the procedure for plume capture assessment introduced in Section 6.3 of this
document could not be utilized for this study. An alternate but similar approach for assessing plume capture
capabilities from the results of this study is detailed below in Section 6.5.
    0.2 -1
   0.15
                                                                  200
                                                                                 -Flux
                                                                                 -Wind direction from Normal
   -0.25
                                                                  -200
                                  Time
Figure 25.   Time series of wind direction and calculated sulfur hexafluoride fluxes from the 20 meter release (as
           analyzed along the 200 meter VRPM configuration)
                                                                                                        49

-------
6.4.2  60-Meter Releases

The 60-meter tracer gas release study was conducted on July 7. During this survey, the sulfur hexafluoride
tracer gas was released from a distance 60 meters upwind of the VRPM configurations, while acetylene was
released from a location 20 meters upwind of the configurations. Data was collected for approximately 3
hours. However, the actual data used for the analysis was collected from 2:26 p.m. to 3:25 p.m., during the
period of favorable wind conditions. During this period, the prevailing wind directions ranged from 1° to 23°
from perpendicular to the longest VRPM configuration.

The average calculated sulfur hexafluoride flux rate along the shortest VRPM configuration was 0.02 ± 0.008
grams per second. The average calculated sulfur hexafluoride flux rate  along the longest VRPM
configuration was  0.126 ± 0.077 grams per second.

The average calculated acetylene flux rate along the shortest VRPM configuration was 0.10 ± 0.036 grams
per second. The average calculated acetylene flux rate along the longest VRPM configuration was 0.140 ±
0.019 grams per second. Figure 26 presents a time series of the calculated flux values of acetylene and
sulfur hexafluoride measured along the two configurations.

The figure shows that the lowest flux values for each of the measurements was observed during the first few
minutes of the release, as the tracer gas concentrations accumulated, and were eventually carried by the
prevailing wind through the configuration.  In comparing the calculated flux values of each gas measured on
the short and  long configurations,  it is apparent that greater plume  capture was achieved with the longer
VRPM configurations.

6.4.3  100-Meter Releases

The 100 meter tracer gas release  study was conducted on June 19. During this survey, the sulfur
hexafluoride tracer gas was released from a distance 100 meters upwind of the VRPM configurations, while
acetylene was released from a location 20 meters upwind of the configurations. Data was collected for
approximately 2 hours. However, the actual data used for the analysis was collected from 5:28  to 5:54 p.m.,
and 6:11 p.m. to 6:43 p.m., during the period of favorable wind conditions. During this period, the prevailing
wind directions ranged from 2° to 29° from perpendicular to the longest VRPM configuration.

The average calculated sulfur hexafluoride flux rate along the shortest VRPM configuration was 0.059 ±
0.024 grams per second. The average calculated sulfur hexafluoride flux rate along the longest VRPM
configuration was  0.120 ± 0.059 grams per second.
                                                                                                       50

-------
       0.35
      -0.05
             -.24  13:55:12  14:24:00  14:52:48  15:21:36   15:50:24   16:19:12   16:43:00
                                         Time
Figure 26. Time series of acetylene and sulfur hexafluoride flux values from the 60 meter release survey
The average calculated acetylene flux rate along the shortest VRPM configuration was 0.067 ± 0.019 grams
per second. The average calculated acetylene flux rate along the longest VRPM configuration was 0.166 ±
0.036 grams per second. Figure 27 presents a time series of the calculated flux values of acetylene and
sulfur hexafluoride measured along the two configurations.
                                                                                                          51

-------
             0.25
              0.2
             0.15
             0.05
              16:.
            -0.05
                 8:00  17:02:24 17:16:48 17:31:12 17:45:36 18:00:00 18:14:24 18:28:48  18:43:12
                                             Time
Figure 27. Time series of acetylene and sulfur hexafluoride flux values from the 100 meter release survey
In comparing the calculated flux values of each gas measured on the short and long configurations, it is
apparent that greater plume capture was achieved with the longer VRPM configurations. The measurements
along the shortest VRPM configuration did not capture the entire plume during most periods of the
measurements.

6.4.4  140-Meter Releases

The 140-meter tracer gas release study was conducted on July 5. During this survey, the sulfur hexafluoride
tracer gas was released from a distance 140 meters upwind of the VRPM configurations, while acetylene
was released from a location 20 meters upwind of the configurations. Measurements were collected for
approximately  3 hours. However, the actual data used for the analysis was collected from 1:04 p.m. to 1:30
p.m., 1:53 p.m. to 2:23 p.m., and 2:58 p.m. to 3:19 p.m., during the period of favorable wind conditions.
During this period, the prevailing wind directions ranged from 17° to 30° from perpendicular to the longest
VRPM configuration.
                                                                                                         52

-------
The average calculated sulfur hexafluoride flux rate along the shortest VRPM configuration was 0.019 ±
0.013 grams per second. The average calculated sulfur hexafluoride flux rate along the longest VRPM
configuration was 0.072 ± 0.048 grams per second.

The average calculated acetylene flux rate along the shortest VRPM configuration was 0.055 ± 0.015 grams
per second. The average calculated acetylene flux rate along the longest VRPM configuration was 0.118 ±
0.032 grams per second. Figure 28 presents a time series of the calculated flux values of acetylene and
sulfur hexafluoride measured along the two configurations.
      0.18
      -0.02
            :46  13:10:34   13:39:22   14:08:10  14:36:58   15:05:46   15:34:34
                                      Time
Figure 28. Time series of acetylene and sulfur hexafluoride flux values from the 140 meter release survey
The figure shows that the lowest flux values for each of the measurements was observed during the first few
minutes of the release, and again near the end of the release. In comparing the calculated flux values of
each gas measured on the short and long configurations, it is apparent that greater plume capture was
achieved with the longer VRPM configurations.
                                                                                                        53

-------
6.5  Summary of Release Results

Table 10 presents a summary of the average calculated flux values of each tracer gas from each release of
the study.

       Table 10. Average calculated flux values from the 60,100, and 140 meter releases*
Tracer Gas
Sulfur Hexafluoride
Sulfur Hexafluoride
Acetylene
Acetylene
VRPM
Configuration
Short
Long
Short
Long
60-Meter
Release Flux
Value (g/s)
0.015
0.126
0.099
0.140
100-Meter
Release Flux
Value (g/s)
0.059
0.120
0.067
0.166
140-Meter
Release Flux
Value (g/s)
0.019
0.072
0.055
0.118
       *During each release, the mass flow meters used for each gas were pre-set to a release rate
        of 0.11  grams per second.

As mentioned previously, the release rate of the tracer gases was determined during the study by using
mass flow meters to control the release rate of the gases. The mass flow meters were set to a flow rate of
0.11 grams per second for each gas, for the duration of the study. In addition to the pre-set flow rates, the
study used a digital scale to confirm the release rate of the tracer gases. Although the scale malfunctioned
early in the study, the scale was used to determine a flow rate of 0.140 grams per second for the acetylene
during the 20 meter release study.

An initial analysis of the data presented in Table 10 shows that in general, the flux values measured along
the longer VRPM configurations were much closer to the actual release rates, as determined by the mass
flow meters. Additionally, the sulfur hexafluoride flux values determined along the longest VRPM
configuration during the 60 meter releases indicated a  much better plume capture than the flux value
determined during the 140 meter and 100 meter release. Also, as expected since the acetylene release was
constantly located 20 meters upwind of the VRPM configurations, the acetylene flux values (calculated along
both VRPM configurations during each release) consistently indicated a perfect plume capture  unlike the
corresponding sulfur hexafluoride releases.

Additional analysis was done on the sulfur hexafluoride concentration values measured along the top two
beams of the longest VRPM configuration during each  release. A t-test was performed to determine if there
was a statistically significant difference in the sulfur hexafluoride concentration values (no statistically
significant difference would indicate that the VRPM configuration was not fully capturing the sulfur
hexafluoride plume in the vertical direction). The results of the t-test indicated that there was a statistically
                                                                                                        54

-------
significant difference for the data from each release, indicating that there were no issues with vertical plume
capture during the study.

Section 6.6 of this document presents an additional analysis of the plume capture of the VRPM
configurations during this study.

6.6  Assessment of Plume Capture

As discussed in Section 6.4.1, an analysis of the data collected during the 20 meter release indicated that
the data was not sufficient for use in the study. Due to these results, the procedure for plume capture
assessment introduced in Section 6.3 of this document could not be utilized for this study.

A slightly different approach for plume capture assessment was applied. The approach involves considering
the average acetylene and sulfur hexafluoride flux values calculated along the longest VRPM configuration
for each release, and expressing them in terms of percent recovery, where percent recovery is equal to the
ratio of the calculated flux value of the tracer gas to 0.11 grams per second, which is also the value
determined from the mass flow meters. Table 11 presents the results of this calculation.
                   Table 11.   Plume capture percentages determined along the long
                              VRPM configuration from the 60-, 100-, and 140-meter
                              releases

60-m Release
100-m Release
140-m Release
Acetylene
127%
151%
107%
Sulfur Hexafluoride
115%
109%
65%
As mentioned previously, the recovery percentage of each tracer gas may differ slightly due to differences in
the physical and chemical properties of the gases. Additionally, atmospheric conditions could possibly affect
the recovery of the tracer gases. In order to eliminate these factors as a variable in the data analysis, the
absolute sulfur hexafluoride plume capture percentages from the 60,100 and 140 meter releases (shown in
Table 10), were normalized to the corresponding acetylene plume capture percentages releases to yield a
sulfur hexafluoride plume capture percentage (as was proposed in the original approach presented in
Section 6.3). Table 12 presents the results of these calculations.
                                                                                                        55

-------
Table 12.   Plume capture percentages determined along the long VRPM configuration from the 60-, 100-,
           and 140-meter releases
Sulfur
Hexafluoride
Release
60-m Release
100-m Release
140-m Release
Plume Capture
90%
72%
61%
The results in Table 12 show that although the sulfur hexafluoride plume capture percentages are
reasonable for the 60 meter, the hexafluoride plume capture percentage gradually decreases with increasing
upwind distance to 61% at an upwind release distance of 140 meters.

6.7  Conclusions from the Results of the Study

The results of the study provided valuable information regarding the plume capture capabilities of the VRPM
method. The following is a summary of the results of the study:

•   The flux values measured along the shorter VRPM  configuration were always less than the flux values
    measured along the longer VRPM configuration for corresponding releases, indicating less plume
    capture along  the shorter configuration (see Table 10). In some cases, the flux values measured  along
    the shorter configuration were more than 50% less than the corresponding flux values measured along
    the longer configuration.

•   The average acetylene flux values calculated along the longest VRPM configuration (0.14, 0.17, and
    0.12) were greater than the actual release rate of 0.11 determined with the mass flow meter.

•   The acetylene plume capture percentages were consistently higher than the sulfur hexafluoride plume
    capture percentages. This result is not surprising, since the acetylene was released closer to the
    configuration,  at a fixed upwind distance of 20 meters, indicating a perfect plume capture.

•   The sulfur hexafluoride plume capture percentages measured along the longer VRPM configuration (see
    Table 12) indicated reasonable plume capture during the 60 meter release (90%) However, the plume
                                                                                                       56

-------
    capture percentage gradually decreased down to 61% at furthest upwind release distance of 140
    meters.

Based on these results, the following recommendations are made for deploying the VRPM method for future
studies:

•   The length of the VRPM configuration should always be extended as far as possible, considering
    constraints such as site topography, and instrument signal limitations. The results of the VRPM plume
    capture study suggest that the longer the length of the VRPM configuration, the better the plume capture
    percentage.

•   The results of the study showed that when using a VRPM configuration with a length of approximately
    200 meters, the method achieved reasonable plume capture from a source located 60 meters upwind of
    the configuration when using a wind criterion of within 30° of perpendicular to the configuration. The
    results also showed that plume capture percentage decreased nearly linearly as the distance of the
    upwind source location increased. When considering source locations greater than 60 meters upwind of
    the VRPM configuration, a tighter wind criterion would probably result in a better plume capture
    percentage. Another factor that can affect the plume capture percentage  is the location of the emissions
    hot spot with respect to the VRPM configuration. The VRPM configuration should be deployed  so that
    the location of suspected upwind emissions hot spot is approximately near the center point of the VRPM
    configuration. In  orderto determine the location  of the major emissions hot spots, a Horizontal  RPM
    survey should be conducted before the VRPM survey to provide guidance for deploying the VRPM
    configuration.

6.8  QA/QC

6.8.1  Equipment Calibration

As stated in the ECPD Optical Remote Sensing Facility Manual (USEPA, 2004), all equipment is calibrated
annually or cal-checked as part of standard operating procedures. Certificates of calibration are kept on file.
Maintenance records are kept for any equipment adjustments or repairs in bound project notebooks that
include the data and description of maintenance performed.  Instrument calibration procedures and
frequency are listed in Table 13 and further described in the text.

6.8.2  Assessment of DQI Goals

The critical measurements associated with this project and the established data quality indicator (DQI) goals
in terms of accuracy, precision, and completeness are listed in Table  14. More information on the
                                                                                                       57

-------
procedures used to assess DQI goals can be found in Section 10 of the ECPD Optical Remote Sensing
Facility Manual (USEPA, 2004).

6.8.3  DQI Check for Analyte PIC Measurement

The precision and accuracy of the analyte PIC measurements was assessed by analyzing the measured
nitrous oxide concentrations in the atmosphere. A typical background atmospheric concentration for nitrous
oxide is about 315 ppb. This value may fluctuate due to seasonal variations in nitrous oxide concentrations
or elevation of the site.

The precision of the analyte PIC measurements was evaluated by calculating the relative standard deviation
of each data subset. A subset is defined as the data collected along one particular path length during one
particular survey in one survey sub-area. The number of data points in a data subset depends on the
number of cycles used in a particular survey.

The accuracy of the analyte PIC measurements was evaluated by comparing the calculated nitrous oxide
concentrations from each data subsets to the background value of 315 ppb. The number of calculated
nitrous oxide concentrations that failed to meet the DQI accuracy criterion in each data subset was recorded.

Overall, 25 data subsets were analyzed from this field campaign. Based on the DQI criterion set forth for
precision of ±10%, all of the data subsets were found to be acceptable, for a completeness of 100%. The
range of calculated relative standard deviations for the data subsets from this field campaign was 0.75 to
13.2 ppb, which represents 0.24 to 4.19% RSD.

Each data point (calculated nitrous oxide concentration) in the 25 data subsets was analyzed to assess
whether or not it met the DQI criterion for accuracy of ± 25% (315 ± 79 ppb) for path lengths less than 50
meters, ±15% (315 ± 47 ppb) for path lengths between 50 and 100 meters, and ± 10% (315 ± 32 ppb) for
path lengths greater than 100 meters. A total of 1169 data points were analyzed, and 1167 of the points met
the DQI criteria for accuracy for a completeness of 99%.
                                                                                                      58

-------
Table 13. Instrumentation calibration frequency and description
Instrument
IMACC, Inc. OP-FTIR
AIL, Inc. OP-FTIR
R.M. Young
Meteorological Head
R.M. Young
Meteorological Head
Topcon Model GTS-
21 1D Theodolite
Topcon Model GTS-
21 1D Theodolite
Digital Scale
(2) Environics Mass
Flowmeters
Measurement
Analyte PIC
Analyte PIC
Wind Speed in miles/hour
Wind direction in degrees
from North
Distance Measurement
Angle Measurement
Mass of Tracer Gas
Cylinders
Flow rate of acetylene and
sulfur hexafluoride tracer
releases
Calibration Date
Pre-deployment and in-field
checks
Pre-deployment and in-field
checks
June 7, 2006
June 7, 2006
April 19, 2006
April 19, 2006
January 2006
January 10, 2006 and March
23, 2006
Calibration Detail
MOP-6802 and 6823 of the ECPB
Optical Remote Sensing Facility
Manual
MOP-6802 and 6823 of the ECPB
Optical Remote Sensing Facility
Manual
APPCD Metrology Lab Cal. Records
on file
APPCD Metrology Lab Cal. Records
on file
Calibration of distance
measurement.
Actual distance =19.6 m
Measured distance = 19.56 m
Measured distance = 19.55 m
Calibration of angle measurement.
Actual angle = 360°
Measured angle = 360°28'47"
Measured angle = 359°39'24"
APPCD Metrology Lab Cal. Records
on file
APPCD Metrology Lab Cal. Records
on file
                                                                                                           59

-------
Table 14. Data quality indicator goals for the project
Measurement
Parameter
Analyte PIC
Ambient Wind
Speed
Ambient Wind
Direction
Distance
Measurement
Tracer Gas
Cylinder Mass
Prevailing
Wind Direction
Analysis Method
OP-FTIR: Nitrous Oxide
Concentrations
R.M. Young Met heads
post-deployment
calibration in EPA
Metrology Lab
R.M. Young Met heads
post-deployment
calibration in EPA
Metrology Lab
Theodolite- Topcon
Digital Scale
R.M. Young Met heads
Accuracy
±25%/15%/10%a
± 1 m/s
±10°
± 1 m
±0.1 kg
N/A
Precision
± 10%
± 1 m/s
±10°
± 1m
±0.1 kg
N/A
Detection
Limit
See Table
5-1
N/A
N/A
0.1 m
N/A
N/A
Completeness
90%
90%
90%
100%
100%
1 hour of data during
periods that the wind is
within 30° of perpendicular
to the VRPM configuration
aThe accuracy acceptance criterion of ± 25% is for pathlengths of less than 50m,
100m, and ±10% is for pathlengths greater than 100m.
± 15% is for pathlengths between 50 and
6.8.4  DQI Checks for Ambient Wind Speed and Wind Direction Measurements

The meteorological head DQIs are checked annually as part of the routine calibration procedure. The R.M.
Young Meteorological heads used in the current study were calibrated by the EPA Metrology Lab on June 7,
2006. The precision and accuracy of the heads is assessed by conducting a post-deployment calibration in
the EPA Metrology Lab using the exhaust from a bench top wind tunnel. This calibration procedure differs
from the procedure used to perform the annual calibration of the instruments. The results of the post-
deployment calibration are pending, as the  instrumentation has been deployed for other field campaigns.

Additionally, a couple of reasonableness checks are performed in the field on the measured wind direction
data. While data collection is occurring, the  field team leader compares wind direction measured with the
heads to the forecasted wind direction for that particular day. Another reasonableness check involves
manually setting the vane on the meteorological heads to magnetic north (this is done with a hand held
compass). The observed wind direction during this test should be very close to 360°.
                                                                                                         60

-------
6.8.5  DQI Checks for the Topcon Theodolite

Calibration checks are not performed before each field campaign. However, the following checks were made
on April 19, 2006. The calibration of distance measurement was done at the EPA Facility using a tape
measure. The actual distance was 19.6 m., and the measured distances were 19.56 m and 19.55 m. The
results indicate accuracy and precision fall well within the DQI goals. The calibration of angle measurement
was also performed. The actual angle was 360°, and the measured angles were 360°28'47" and 359°39'24".
The results indicate accuracy and precision fall well within the DQI goals.

Additionally, there are several internal checks in the theodolite software that prevent data collection from
occurring if the instrument is not properly aligned on the object being measured, or if the instrument has not
been balanced correctly. When this occurs, it is necessary to re-initialize the instrument to collect data.

6.8.6  QC Checks of OP-FTIR Instrument Performance

Several diagnostic checks were performed on the OP-FTIR instrumentation  prior to deployment to the field,
and during the duration of each field campaign. These checks involve assessing the electronic noise of the
instrument, the strength of the instrument signal, and features in the collected data  spectrum. The results of
these tests are used to determine whether or not the instrument is functioning properly. More information on
the diagnostic checks that are performed as part of a typical ORS field campaign can be found in MOP 6802
and 6823 of the ECPD Optical Remote Sensing Facility Manual (USEPA, 2004).

In addition to the QC checks performed on the OP-FTIR, the quality of the instrument signal (interferogram)
was checked constantly during the field campaigns. This was done by ensuring that the intensity of the
signal is at least five times the intensity of the stray light signal (the stray light signal is collected as
background data prior to actual data collection, and measures internal stray  light from the instrument itself).
In addition to checking the strength of the signal, checks were done constantly in the field to ensure that the
data were being collected and stored to the data collection computer. During the campaign, a member of the
field team monitored the data collection computer to make sure these checks were completed.

Prior to instrument deployment, a series of QC checks were performed on the IMACC OP-FTIR to assess
the instrument performance. On June 9, 2006, the single beam ratio, baseline stability, noise equivalent
absorbance, ZPD stability, saturation, random baseline noise, and stray light diagnostic tests were
performed. The results of the tests indicated that the IMACC OP-FTIR was operating within the acceptable
criteria range.

Due to a malfunction with one of the IMACC OP-FTIR instruments, it was necessary to use the AIL, Inc. OP-
FTIR on the first day of the project.  Because of this unexpected change, it was not  possible to  perform the
series of pre-deployment QC checks on the AIL, Inc. OP-FTIR. However, the same series of QC checks
                                                                                                       61

-------
were performed on the same instrument shortly before and after the current study, as part of other projects
(on April 27, 2006 and July 16, 2006). The results of these checks indicated that the AIL, Inc. OP-FTIR was
operating within the acceptable criteria range.
                                                                                                        62

-------
                                7.  Quality Assurance Methods

Quality Assurance methods are critical to any measurement project. Over the course of this long-term
evaluation study, U.S. EPA and ARCADIS have worked on developing and improving the QA/QC
procedures used for conducting measurements of fugitive emissions using ORS instrumentation and the
RPM method. Many of these improvements were implemented as a result  of information gathered from the
long-term evaluation study, and review of the Quality Assurance Project Plans submitted for the
measurement campaigns. Some of the major QA improvements implemented include:

•   A more thorough documentation of the calibration schedule for the ancillary equipment used in the
    campaigns

•   The development of pre-deployment tests to check the precision and accuracy of the meteorological
    heads

•   The development of pre-deployment and in-field checks of the OP-FTIR instruments to detect potential
    problems that may effect data quality

•   A more detailed explanation of checks that should  be done on the OP-FTIR during data collection to
    ensure signal strength and proper mirror alignment

•   The establishment of Data Quality Indicators to assess the precision and accuracy of the concentration
    data collected with the OP-FTIR

•   The development of manual checks that can be done to verify the accuracy of the surface concentration
    contour maps, and the reconstructed plume maps

These points are discussed in greater detail  in the U.S. EPA Emissions Characterization and  Prevention
Branch (ECPB) Optical Remote Sensing Facility Manual (U.S. EPA, 2004). Although this document was
created as part of a separate project, the development of the document benefited from information  and
knowledge gathered from the long-term evaluation study.

The following subsections contain details on the quality assurance assessment done for the Orange County
Landfill measurement campaign, including an explanation  of some of the procedures developed to  assess
data quality for applying the RPM method using ORS instrumentation. This section also presents the results
of a tracer gas release done during the Somersworth, NH campaign to assess the accuracy of the VRPM
method, and a comparison of methane concentrations  determined using different quantification software
packages.
                                                                                                    63

-------
7.1  ORS Instrumentation Calibration

7.1.1  Quality Assurance of the OP-FTIR Instruments

The OP-FTIR instruments are not calibrated in a classical sense, due to the fact that they are open-path
instruments, and do not contain a closed sample cell. However, the accuracy and precision of the
concentration measurements are analyzed by comparing the measured nitrous oxide concentrations to a
known concentration in the atmosphere. Atypical background atmospheric concentration for nitrous oxide is
about 315 ppb. However, this value may fluctuate due to seasonal variations in nitrous oxide concentrations
or elevation of the site.

The precision of the analyte concentration measurements were evaluated by calculating the relative
standard deviation of each data subset. A subset is defined as the data collected along one particular path
length during one  particular survey in one survey sub-area. The number of data points in a data subset
depends on the number of cycles used in a particular survey.

The accuracy of the analyte concentration measurements was evaluated by comparing the calculated
nitrous oxide concentrations from each data subsets to the background concentration of 315 ppb. The
number of calculated nitrous oxide concentrations that failed to meet the accuracy criterion in each data
subset was recorded.

Overall,  77 data subsets were analyzed from this field campaign. Based on the criterion set forth for
precision of ± 10%, 75 of the 77 data subsets were found to be acceptable for a completeness of 97%. The
range of calculated relative standard deviations for the data subsets from this field campaign was 1.13 to
50.5 ppbm, which  represents 0.35 to 16% RSD.

Each data point (calculated nitrous oxide concentration) in the 77 data subsets were analyzed to assess
whether or not it met the criterion for accuracy of ± 25% (315  ± 79 ppb) for path lengths less than 50  meters,
±15% (315 ± 47 ppb) for path lengths between 50 and 100 meters, and ± 10% (315 ± 32 ppb) for path
lengths greater than 100 meters. A total of 2763 data points were  analyzed, and 2709 met the DQI criteria
for accuracy for a  completeness of 98%. Based on the criterion set forth for accuracy and precision, the OP-
FTIR data was found to be acceptable.

In addition to the nitrous oxide concentration check, several QC checks have been developed to assess the
performance of the OP-FTIR Instrument. These checks are performed prior to, and during deployment. The
QC checks involve assessing instrument noise, the strength of the instrument signal, and features in  the
collected data spectrum. The results of these tests are used to determine whether or not the instrument is
functioning properly.
                                                                                                       64

-------
In addition to the QC checks performed on the OP-FTIR, the strength of the instrument signal
(interferogram) is checked constantly during the field campaign. In addition to checking the strength of the
signal, checks are performed constantly in the field to ensure that the data is being collected and stored to
the data collection computer.

7.1.2  Quality Assurance of Unisearch OP-TDLAS Instrument

The accuracy and precision of the Unisearch OP-TDLAS are checked by the insertion of reference cells,
containing gas from the calibrations standards, into the optical path of the instrument. The Unisearch OP-
TDLAS response was evaluated prior to performing the VRPM survey on May 4. The response was
evaluated by inserting calibration cells into the optical path containing gas at a known concentration. The
change in OP-TDLAS response is due to the added gas within the calibration  cells. The OP-TDLAS
response indicated an average difference of 5.3 percent from the calculated OP-TDLAS concentrations. The
OP-TDLAS response and evaluation is limited by the air concentrations existing at the time of the evaluation.
Air concentrations changed ~ 2 percent during this response evaluation. Table 15 presents a summary of
the calibration of the Unisearch OP-TDLAS instrument. Figure 29 shows a plot of the instrument calibration
response. More information on the calibration procedures for the Unisearch OP-TDLAS instrument can be
found in the ECPB Optical Remote Sensing Facility Manual (U.S. EPA, 2004).
                                                                                                      65

-------
      Table 15. Summary of calibration results of the Unisearch OP-TDLAS instrument
Input
No Cell

Empty Cell

1%, 4/28/05

2.5%, 11/03/03
2.5%, 04/28/05

Response
PAC
3.522359
2.858483
3.949112
3.634309
11.45878
11.27292
21.33168
22.44113
22.11483
PIC
461.429
374.4612
517.3336
476.0945
1501.1
1476.753
2794.45
2939.788
2897.043
Avg PIC
417.9451

496.7141

1488.926

2794.45
2918.416

DiffPIC
1.8

0

992.2121

2297.736
2421.701

QA Value


0

1000

2500
2500

% Diff


0.0

0.8

8.1
3.1

                 3000 i
                              500      1000      1500     2000
                                          TDL Response. PIC
2500
3000
           Figure 29. Plot of the Unisearch OP-TDLAS instrument calibration response
At the time of the Orange County measurement campaign, the Boreal OP-TDLAS system had only recently
been acquired by ARCADIS. Consequently, standard operating and calibration procedures for the Boreal
system are still being developed.
                                                                                                    66

-------
7.1.3  Quality Assurance ofthe Boreal OP-TDLAS Instrument

The Boreal GasFinder 2.0 OP-TDLAS provides an R2 value for each concentration measurement. The R2
value is calculated by the internal software ofthe instrument, and is an indication ofthe similarity between
the waveform ofthe sample gas and the reference cell gas. When the instrument detector receives the
returning laser signal after it has passed through the sample beam path, it converts the signal to the shape
of a specific waveform (sample waveform). The instrument also receives a similar laser signal after the laser
has passed through the reference cell in the instrument (reference waveform). The two waveforms are then
digitized and compared as two numeric arrays. The instrument software then performs a linear least squares
regression for each measurement, to evaluate the similarity (R2) between the sample and reference
waveforms.

The instrument provides the R2 value as an output with every collected  measurement. The value is used to
assess the accuracy of each concentration measurement. Table 16, taken from the Boreal Laser, Inc.
GasFinder 2.0
measurement.
GasFinder 2.0 Operation Manual, presents a range of R2 values, and the corresponding accuracy ofthe
               Table 16. Accuracy of concentration measurements for different R2 values
R2
>0.95
0.9
0.7
0.5
0.4
0.3
0.15
0.1
<0.05
Measurement Accuracy
±2%
±5%
±10%
±15%
± 20%
± 25%
± 50%
± 70%
± 100%
During the Orange County measurement campaign, the R2 value of each concentration measurement was
greater than 0.7, indicating that the accuracy of each measurement was greater than ± 10%.
                                                                                                     67

-------
7.2  Non-ORS Instrumentation Calibration

As stated in the ECPD Optical Remote Sensing Facility Manual (U.S. EPA, 2004), all equipment is
calibrated annually or cal-checked as part of standard operating procedures. Certificates of calibration are
kept on file. Maintenance records are kept for any equipment adjustments or repairs in bound project
notebooks that include the data and description of maintenance performed.  Instrument calibration
procedures and frequency are listed in Table 17.
Table 17. Instrumentation calibration frequency and description
Instrument
Climatronics Model 101990-
G1 Meteorological Heads
Climatronics Model 101990-
G1 Meteorological Heads
R.M. Young Meteorological
Heads
R.M. Young Meteorological
Heads
Topcon Model GTS-21 1D
Theodolite
Topcon Model GTS-21 1D
Theodolite
Measurement
Wind Speed in
miles/hour
Wind direction in
degrees from North
Wind Speed in
miles/hour
Wind direction in
degrees from North
Distance
Measurement
Angle Measurement
Calibration Date
14 April 2005
14 April 2005
14 April 2005
14 April 2005
26 May 2004
26 May 2004
Calibration Detail
APPCD Metrology Lab Cal. Records on file
APPCD Metrology Lab Cal. Records on file
APPCD Metrology Lab Cal. Records on file
APPCD Metrology Lab Cal. Records on file
Calibration of distance measurement.
Actual distance = 30 ft.
Measured distance = 30.1 ft., and 30.2 ft.
Calibration of angle measurement.
Actual angle = 360°
Measured angle = 360°28'59", and 360°12'
37"
7.3  VRPM Tracer Release Validation Study

The first field campaign of the long-term evaluation study was conducted at a Superfund site in
Somersworth, New Hampshire (Modrak et a/., 2004). As part of this field campaign, a tracer release study
was done to validate the accuracy of the VRPM method.

Ethylene was released through a soaker hose configuration located approximately 30 meters upwind of the
VRPM configuration. The wind direction during the time of the release was almost directly perpendicular to
the VRPM configuration. The soaker hoses were set up in an "H" configuration to simulate an area source.
The approximate dimensions of the "H" configuration were 10 meters wide, and 40 meters long (on each
side). The weight of the ethylene cylinder was recorded prior to release of the gas, and  immediately after the
release was completed, using a digital scale. In addition, the precise starting and ending time of the release
                                                                                                       68

-------
was recorded in order to calculate the average actual flux of ethylene. This flux value was then compared to
the ethylene flux calculated from the VRPM survey.

Figure 30 shows a map of the average reconstructed ethylene plume from the release. The contour lines
show ethylene concentrations in ppm. The average calculated ethylene flux rate was 0.98 g/s.
               12
               10
             «  8
             v
RPM Determination = 0.98 g/s
Actual Rate      =1.01 g/s
                       20     40      60      80      100     120
                                         Crosswind Distance (meters]
                                              140
                                                     160
                                                            180
Figure 30.  Reconstructed ethylene plume from the VRPM validation study conducted during the Somersworth,
           NH field campaign (concentrations shown in ppmv). The location of the vertical structure is shown
           by the solid black vertical line. The scanning ORS instrument is located in the bottom left-hand
           corner of the figure
                                                                                                          69

-------
The ethylene tracer gas was released for 75 minutes. During this period, the measured mass of the ethylene
cylinder was reduced by 4.59 kg. A loss of 4.59 kg over a 75-minute period indicates an average flow rate of
1.01 g/sec. The measured emission rate indicates an ethylene mass recovery by the VRPM method of 97%.

The favorable results found were partly due to the fact that the prevailing winds were nearly perpendicular to
the VRPM configuration over the duration  of the release. This allowed the configuration to capture a large
amount of the ethylene plume from the site. Another factor that contributed to the favorable results found
was the small variability in wind direction and speed during the period of the survey that indicates very stable
atmospheric conditions. Flux calculations in unstable atmospheric conditions tend to underestimate down to
60% of the actual fluxes (Hashmonay et al., 2001).

7.4 Comparison of Methane Concentration Determination Using the Two Software Packages

As part of the  long-term evaluation study, an evaluation of the performance of the two quantification software
packages was done by comparing methane concentrations values determined with IMACCQuant to
methane  concentration values determined with Non-Lin software. The first comparison was done by post-
analyzing the  same raw data (interferograms) with both software packages. The results of the comparison
are presented in Figure  31.

The results of the comparison show that in general, the Non-Lin software quantified higher methane
concentrations than the IMACCQuant software. The higher concentrations analyzed with Non-Lin could be a
result of an artifact of noise or water vapor interference in the data, which if not filtered out, would yield a
higher  concentration analysis. Further analysis of the data found that a larger discrepancy between the
concentrations determined with the two software packages occurred in data where the IMACCQuant data
indicated  a larger amount of noise.  Unfortunately, the Non-Lin software does not include the ability to assess
the amount of noise  in the analyzed data. This is unfortunate, as it does not allow the user to perform an
assessment of the quality of the data analyzed.

An additional comparison of the methane concentrations analyzed using different methods was done by
comparing the concentrations determined  in real-time and post-collection, using the  IMACCQuant software.
The results of the comparison are presented in Figure 32.

The results show that although the  results were correlated well, the real-time methane concentration
determinations were generally lower than the concentration determinations analyzed post-collection.
                                                                                                       70

-------
         Comparison of Methane Concentration Analysis Using the Non-
                   Lin and IMACCQuant Software Packages
        18.000
        16
         0.000
            0.000
                       5.000      10.000      15.000      20.000

                          Non-Lin Methane Determination (ppm)
                                                                 25.000
Figure 31.   Comparison of methane concentration analysis using the Non-Lin and
            IMACCQuant software packages
Comparison of Methane Concentration Analysis Using IMACCQuant
Software in Real-Time and Post-Collection
R _
Real -Time Methane Determination
(ppm)
7
R

1
0
0
1
n
•
x"
>^
af
**J*
•^r * y = 0.8497x
Vf>«»* » R2 = 0.9209



0. 000 2. 000 4. 000 6. 000 8. 000 1 0. 000
Post-Collection Methane Determination (ppm)
Figure 32.   Comparison of real-time and post-collection methane concentration analysis
           using the IMACCQuant software package
                                                                                            71

-------
Future of Using Optical Remote Sensing with the Radial Plume Mapping Method for Emissions Measurements
The results of the long-term evaluation study show that ORS instrumentation used with the RPM method is a
viable solution for characterizing fugitive emissions from landfill sites, and other large area sources.

In addition to landfill sites, the method has been applied at agricultural sites to measure emissions fluxes
from animal houses and lagoons, wastewater treatment plants to measure emissions from lagoons and
reactors, and at gas station facilities to evaluate emissions from the gas dispensing areas, underground
storage tanks (UST), and LIST vents. Additionally, ARCADIS has deployed ORS instrumentation to provide
fence line emissions monitoring during a cleanup at an environmental site. ARCADIS has also sold an OP-
FTIR -based system to the North Carolina Department of Environment and Natural  Resources (NCDENR)
for deployment in emergency response situations. Table 18 presents a summary of the advantages and
disadvantages of applying the RPM method to the different types of sites, based on  the experiences of the
project team.

EPA and ARCADIS are currently planning additional measurement campaigns at landfill sites. The
campaigns will be done solely to characterize methane emissions at the sites using  the HRPM and VRPM
methods. Since methane will be the only compound of interest, the campaigns will use only a scanning OP-
TDLAS system. This approach will reduce the cost of instrumentation needed for the project, and  the
number of personnel needed for the measurements (reducing the deployment costs). This measurement
approach could be very useful to  landfill operators, as a scanning OP-TDLAS system could be permanently
deployed at a landfill site to perform periodic surface methane emissions monitoring and emissions flux
measurements. The results of this monitoring could improve safety at the sites by identifying surface
methane hot spots, and help assure compliance with federal regulations.

The future of the application of ORS instrumentation and the RPM  method also includes improving the
quality assurance and data  collection methods. The creation of the OAQPS protocol and subsequent
approval of EPA Other Test Method 10 for characterizing fugitive emissions from area sources (discussed in
Section 2 of this document) is a major breakthrough in this effort. Further development will be done to create
protocols for applying the RPM method to specific types of area sources such as landfills and industrial
facilities. The guidance will address dealing with challenges specific to the different sites, such as
topography and obstacles.
                                                                                                      72

-------
Table 18.   Summary of the advantages and disadvantages of applying the RPM method to different types
            of measurement sites
  Site
Advantages
Disadvantages
  Landfill
Temporal and spatial emissions data

Likely to capture all major emissions
areas

Ability to directly calculate emissions
rates

Ability to isolate emissions from
specific measurement areas
Relies on favorable wind conditions

Difficulty in characterizing emissions from
side slopes of landfill cell (see Section 4)

Due to large survey cells, some uncertainty
regarding capture of emissions from
sources located a large distance upwind of
VRPM configuration (see Section 4)
  Agricultural Site
Temporal and spatial emissions data

Likely to capture all major emissions
areas

Ability to directly calculate emissions
rates

Ability to isolate emissions from
specific measurement areas
Relies on favorable wind conditions
  Wastewater Treatment Plant
Temporal and spatial emissions data

Likely to capture all major emissions
areas

Ability to directly calculate emissions
rates

Ability to isolate emissions from
specific measurement areas
Relies on favorable wind conditions
  Gas Station Facility
Temporal and spatial emissions data

Likely to capture all major emissions
areas

Ability to directly calculate emissions
rates

Ability to isolate emissions from
specific measurement areas
Relies on favorable wind conditions

Small source area of the UST vents made it
unnecessary to apply the RPM method. A
point sampling approach would have been
a better option.
                                                                                                                   73

-------
                                     Acknowledgements

ARCADIS and EPA would like to thank Gayle Wilson and the staff of the Orange County Municipal Landfill
for allowing the research team to use the facility for the RPM demonstration and VRPM Validation Study.
                                                                                                 74

-------
                                     References

Cowen, K., I. MacGregor, K. Hand, J. Carvitti, M. Rectanus, T. Kelly, and K. Riggs. Environmental
    Technology Verification Report: OPSISAB LD500 Continuous Emission Monitor for Ammonia; U.S.
    Environmental Protection Agency ETV Program, Battelle, Columbus, OH, September 2004.

Hashmonay, R.A., and M.G. Yost, Innovative approach for estimating fugitive gaseous fluxes using
    computed tomography and remote optical sensing techniques, J. Air Waste Manage. Assoc., 49, 966-
    972,1999.

Hashmonay, R.A., D.F. Natschke, K.Wagoner, D.B. Harris, E.L.Thompson, and M.G. Yost, Field evaluation
    of a method for estimating gaseous fluxes from area sources using open-path Fourier transform
    infrared, Environ. Sci. Technol., 35, 2309-2313, 2001.

Hashmonay, R.A., M.G. Yost, and C. Wu, Computed tomography of air pollutants using radial scanning
    path-integrated optical  remote sensing, Atmos. Environ., 33, 267-274,1999.

Hashmonay, R.A., M.G. Yost, D.B. Harris,  and E.L. Thompson, Simulation study for gaseous fluxes from an
    area source using computed tomography and optical remote sensing, presented at SPIE Conference on
    Environmental Monitoring and Remediation Technologies, Boston, MA, Nov., 1998, in SPIE Vol. 3534,
    405-410.

Kelly, T., Z. Willenberg, K. Riggs. Environmental Technology Verification Report: OPSIS AB Hg-200 Mercury
    Continuous Emission Monitor; U.S. Environmental Protection Agency ETV Program, Battelle, Columbus,
    OH, September 2003.

Modrak, M. T.; Hashmonay, R. A.; Kagann, R. Measurement of Fugitive Emissions at a Region I Landfill;
    EPA-600/R-04-001; U.S. Environmental Protection Agency, Research and Development, Work
    Assignment No. 4-003, January 2004.

Modrak, M. T.; Hashmonay, R. A.; Varma R.; Kagann, R. Evaluation of Fugitive Emissions at a Brownfield
    Landfill in Ft. Collins, Colorado Using Ground-Based Optical Remote Sensing Technology; EPA-600/R-
    05/042;  U.S. Environmental Protection Agency, Research  and Development,  Work Assignment No. 0-
    025, March 2005a.

Modrak, M. T.; Hashmonay, R. A.; Varma R.; Kagann, R. Evaluation of Fugitive Emissions at a Brownfield
    Landfill in Colorado Springs,  Colorado Using Ground-Based Optical Remote Sensing Technology; EPA-
    600/R-05/041; U.S. Environmental Protection Agency, Research and Development, Work Assignment
    No. 0-025, March 2005b.
                                                                                                   75

-------
Myers, J., T. Kelly, C. Lawrie, K. Riggs. Environmental Technology Verification Report: OPSIS Inc. AR-500
    Ultraviolet Open-Path Monitor; U.S. Environmental Protection Agency ETV Program, Battelle,
    Columbus, OH, September 2000.

Platt, U., Differential optical absorption spectroscopy (DOAS), In: Air Monitoring by Spectroscopic
    Techniques, Chemical Analysis Series, Vol. 127, John Wiley & Sons, Inc. pp. 27-84,1994.

Thoma, E.D., R.C. Shores, E.L. Thompson, D.B. Harris,  S.A. Thorneloe, R.M. Varma, R.A. Hashmonay,
    M.T. Modrak, D.F. Natschke, and H.A. Gamble; Open-Path Tunable Diode Laser Absorption
    Spectroscopy for Acquisition of Fugitive Emission Flux Data; Journal of Air and Waste Management
    Association, (55), 658-668, 2005.

U.S.EPA, ECPB Optical Remote Sensing Facility Manual, US EPA National Risk Management Research
    Laboratory, Air Pollution Prevention and Control Division, Emissions Characterization and Prevention
    Branch, Contract No. EP-C-04-023, Work Assignment 0-33, April 2004.

Varma, R., R.A. Hashmonay, R. Kagann, M.A. Bolch, Optical Remote Sensing to Determine Strength of
    Nonpoint Sources: Duke Forest Validation Study, ESTCP Report #A528044, Contract No. CP-0214,
    November 2005.
                                                                                                    76

-------
                         APPENDIX A. Radial Plume Mapping Algorithms

Horizontal Radial Plume Mapping (HRPM)

Horizontal Radial Plume Mapping (HRPM) is a technique that provides qualitative localization of the target
compounds in a study. HRPM surveys are performed with the ORS beams located as close to the ground
as practical. This enhances the ability to detect minor constituents emitted from the ground, since the
emitted plumes dilute significantly at higher levels above the ground. The survey area is divided into a
Cartesian grid of n times m rectangular cells. A retro-reflecting mirror is located in each of these cells and
the ORS  instrument scans to each of these mirrors, dwelling on each for a set measurement-time. The
system scans to the mirrors in the order of either increasing or decreasing azimuth angle. The path-
integrated concentrations  measured at each mirror are averaged over several scanning cycles to produce
time-averaged concentration  maps. Meteorological measurements are made concurrent to the scanning
measurements.

The reconstruction algorithm for obtaining surface concentration contour maps consists of two stages. First,
an iterative inversion algorithm is used to retrieve average concentration in each of the cells.  Then, an
interpolation procedure is  applied to the concentration values of each cell to calculate concentration in
higher spatial resolution. Horizontal Radial Plume Mapping is performed using Matlab (MathWorks)
software.

For the first stage of reconstructing the average cell concentrations we apply an iterative algebraic
deconvolution algorithm. The path-integrated concentration (PIC), as a function of the field of concentration,
is given by:

                                          m.  i
                                              \mcm                     (1)
where K is a Kernel matrix that incorporates the specific beam geometry with the cell dimensions; k is the
number index for the beam paths and m is the number index for the cells; and c is the average
concentration in the mth cell. Each value in the Kernel matrix K is the length of the kth beam in the mth cell;
therefore, the matrix is specific to the beam geometry. To solve for the average concentrations (one for each
cell) the Non Negative Least Squares (NNLS) was applied. The NNLS is similar to a classical least square
optimization algorithm, but is constrained to  provide the best fit of non-negative values. The NNLS algorithm
was tested and compared to the relaxation multiplicative algebraic reconstruction technique (MART)
program previously developed and used. Both algorithms gave very similar results when reached to the
same maximal level of fit between the predicted PIC and the observed PIC but the NNLS was much faster.
Therefore, the NNLS algorithm will be applied in this study. This iterative procedure proceeds until the
difference of the criteria parameter between  sequential steps drops below a very small threshold value
(tolerance). The tolerance value depends  on many factors, such as the area dimensions, and number of
beams used in the survey. A typical value for the tolerance is around 10~11. Multiplying the resulted vertical
vector of averaged concentration by the matrix K, yields the end vector of predicted PIC data.

The Concordance Correlation Factor (CCF)  is used to represent the level of fit for the reconstruction in the
path-integrated domain (predicted vs. observed PIC). CCF calculations are performed using Matlab
(MathWorks) software. The CCF is similar to the Pearson correlation coefficient, but is adjusted to account
                                                                                                   A-1

-------
for shifts in location and scale (Lin, 1989). Like the Pearson correlation (correlation coefficient, 'R'), CCF
values are bounded between -1 and 1, yet the CCF can never exceed the absolute value of the Pearson
correlation factor. For example, the CCF will be equal to the Pearson correlation when the linear regression
line intercepts the ordinate at 0, its slope equals 1, and  its absolute value will be lower than the Pearson
correlation when the above conditions are not met (Hashmonay et al., 1999, Wu etal., 1999).

The second stage of the plume reconstruction is interpolation among the nine points,  providing a peak
concentration not limited only to the center of the cells.  We will use the triangle-based cubic interpolation
procedure. To extrapolate data values beyond the peripheral pixel centers and within  the rectangle
measurement domain, we will assign the concentration of each corner cell to the corresponding corner of
the domain.

Vertical Radial Plume Mapping (VRPM)

The VRPM surveys employ at  least five mirrors and one vertical structure to provide the crosswind spatial
definition downwind of the plume. At least three mirrors are placed between the scanning ORS instrument
and the vertical structure, and two mirrors are placed on the vertical structure. The ORS instrument scans in
a constant pattern aimed at each mirror (dwelling on each mirror for 10 to 30 seconds), and PIC values  are
obtained along each mirror to generate a long-term average in each beam path. The flux in each vertical
plane is effectively the product of the  sum of the vertical plane integrated concentration multiplied by the
average wind speed measured during the determinations. The calculated emission flux is then used to yield
an estimated total area emission rate.

We use the smooth basis function minimization (SBFM) reconstruction approach with a two-dimensional
smooth basis function (bivariate Gaussian) in order to reconstruct the smoothed mass equivalent
concentration map. The smoothed mass equivalent concentration map is reconstructed using Matlab
(MathWorks). In the SBFM approach, a smooth basis function is assumed to describe the distribution of
concentrations, and the search is for the unknown parameters of the basis function. Since our interest is in
the plane integrated concentration and not the exact map of concentrations in the plane, we fit only one
smoothed basis function (one bivariate Gaussian) to reconstruct the smoothed map.

However, this methodology does not  assume that the true distribution of concentration in the vertical plane
is a bivariate Gaussian. Earlier computational studies showed that one might fit a single bivariate Gaussian
function to many kinds of skewed distributions and still retrieve a reasonably good estimate of the plane-
integrated concentration (Hashmonay and Yost, 1999). The fit of a single bivariate Gaussian function to a
multiple mode distribution was also examined and found that the reconstructed plane integrated
concentration conserved fairly  well the test input plane integrated concentration.

In each iterative step of the SBFM search procedure, the measured PIC values are compared with assumed
PIC values, calculated from the new set of parameters. In order to compute the assumed PIC values, the
basis function is integrated along the  beam path's direction and path-length.

In our beam geometry, it is convenient to express the smooth basis function G in polar coordinates r and 6.

-------
G(r,ff) = -
             A
(r • cosd - myf   2pu(r-cos0-my}(r-sm0-mz)  (r-$m0-mzf
                                                           (2)
The bivariate Gaussian has six unknown independent parameters:

•  A - normalizing coefficient which adjusts for the peak value of the bivariate surface

•  pi2- correlation coefficient which defines the direction of the distribution-independent variations in
   relation to the Cartesian directions y and z (p12= 0 means that the distribution variations overlap the
   Cartesian coordinates)

•  my and mz - peak locations in Cartesian coordinates

•  and oy and az - standard deviations  in Cartesian coordinates. To fit the unknown parameters of the
   smooth basis function to the PIC data, one has to define an error function for minimization.

The Sum of Squared Errors (SSE) function is defined in our study as:


 SSE (A,pu,my,m!,(ry,(r!) = Z PIC, - JG(r,0i,A,pl2,my,mz,ay,o-z)dr     (3)
Where PIC represents the measured PIC values and the index; is for the different beams. The SSE function
is minimized using an iterative minimization procedure, such as the Simplex method, to solve for the
unknown parameters. These calculations are performed using MatLab (MathWorks).

As mentioned earlier, our interest is in the plane-integrated concentration; therefore, we fit one bivariate
Gaussian surface to match the volume under the underlying true concentration distribution surface. This
volume is highly conserved in the fitting procedure, which emphasizes agreement over the five path
integrals. Six independent beam paths are sufficient to determine one bivariate Gaussian that has six
independent unknown parameters.

Some reasonable assumptions also may be made when applying the SBFM method to this problem, to
reduce the number of unknown parameters to four; (e.g., setting the correlation parameter p12 equal to
zero). This assumes that the reconstructed  bivariate Gaussian is limited only to changes in the vertical and
crosswind directions. In this case Equation 2 reduces  into:
                G(r,0) =
                                           (r-cos0-my)2   (r-sind-mz)2
                                                          (4)
One also can fix the peak location in the vertical direction to the ground level when ground level emissions
are known to exist, as in our field experiment. However, in this methodology, there is no requirement to
apply a priori information on the source location and configuration.

-------
Once the parameters of the function were found for a specific run, we calculate the concentration values for
every square elementary unit in a vertical domain. Then, we integrate these values, incorporating wind
speed data at each height level to compute the flux. In this stage, we convert the concentration values from
parts per million by volume to grams per cubic meter, considering the molecular weight of the target gas and
ambient temperature. This enables us to directly calculate the flux in grams per second, using wind speed
data in meters per second.

-------
                  Appendix B: Results from the Chapel Hill, NC Field Campaign

The results from the ORS data collected during the field campaign are presented in the following
subsections. The methane concentrations presented below represent values above atmospheric
background.

Active Site

HRPM Results

An HRPM survey was conducted in Survey Area #1 on May 2, 2006 using nine optical paths. Figure B-1
presents the average reconstructed methane surface concentration contour map. The blue lines show the
locations of the optical paths, converging at the location of the OP-FTIR instrument.
                  3*30
              I
                                                              100
                                                                      120
              Figure B-1.  Average Methane Surface Concentration Contour Map from the
                        May 2,2006 HRPM Survey of Area #1 (concentrations shown are
                        in ppm above background)
The figure shows the presence of a methane emissions hot spot (having concentrations over 6 ppm above
atmospheric background) located in the northern portion of the survey area. This region of the survey area
was adjacent to the active work face area at the time of the study.

HRPM surveys were conducted in Survey Area #2 on May 3-5. Figures B-2, B-3, and B-4 show the average
reconstructed methane surface concentration contour maps from May 3, May 4, and May 5, respectively.
The blue lines show the locations of the optical paths, converging at the location of the OP-FTIR instrument.
                                                                                                    B-1

-------
                                  10     20     30     40     50     60
              Figure B-2.  Average Methane Surface Concentration Contour Map from the
                          May 3 HRPM Survey of Area #2 (concentrations shown are in ppm
                          above background)
The May 3 HRPM survey (see Figure B-2) detected the presence of a methane hot spot located in the
northern portion of the survey area having concentrations greater than 6 ppm above atmospheric
background levels.

The May 4 HRPM survey (see Figure B-3) detected a hot spot (concentrations greater than 12 ppm above
atmospheric background levels) in the same vicinity as the hot spot detected during the May 3 survey. As
mentioned previously, the HRPM  configuration in Survey Area #2 was extended westward on May 4 and
May 5 by adding three additional beam paths to the configuration. An additional methane hot spot having
concentrations greater than 12 ppm above atmospheric background levels was detected during the May 4
survey along the western  boundary of the survey area.
                                                                                                   B-2

-------
                                       50   SO
Figure B-3.  Average Methane Surface Concentration Contour Map
           from the May 4 HRPM Survey of Area #2 (concentrations
           shown are in ppm above background)
                                      50   60
 Figure B-4.  Average Methane Surface Concentration Contour
            Map from the May 5 HRPM Survey of Area #2
            (concentrations shown are in ppm above background)
                                                                                 B-3

-------
The May 5 HRPM survey (see Figure B-4) detected a methane hot spot having concentrations greater than
6 ppm above atmospheric background levels in the southeastern portion of the survey area. The survey
detected an additional hot spot along the western boundary of the area (having concentrations greater than
7 ppm above atmospheric background) in the same vicinity as the hot spot detected along the western
boundary during the May 4 HRPM survey.

VRPM Results

As mentioned previously, it was not possible to perform a VRPM survey of Survey Area #1 due to the close
proximity of the survey area to the active workface. However, two separate VRPM surveys of Survey Area
#2 were conducted on May 4 using the IMACC OP-FTIR and the Boreal OP-TDLAS, and on May 5 using
the Boreal instrument. Figures B-5 and B-6 present a time series of the calculated downwind methane flux
values from the area and the prevailing wind direction (from normal to the plane of the VRPM configuration),
from the May 4 IMACC OP-FTIR and Boreal OP-TDLAS surveys, respectively.
            I
            8
            5
                        i      i     r i   -j   i      i
                        b  V\ 10 Ay 1b  \ 2d    2
                                     Cycle Number
         Figure B-5.  Time series of wind direction and methane flux values from the May 4 VRPM survey
                    of Survey Area #2 using the IMACC OP-FTIR
                                                                                                  B-4

-------
                    50
                                      Cycle Number
           Figure B-6.  Time series of wind direction and methane flux values from the May 4 VRPM
                      survey of Survey Area #2 using the Boreal OP-TDLAS
The downwind methane flux values from the IMACC OP-FTIR survey (see Figure B-5) ranged from 5.2 g/s
to 17 g/s with an average value of 9.8 g/s. The downwind methane flux values from the Boreal OP-TDLAS
survey (see Figure B-6) ranged from 2.1 g/s to 16 g/s with an average of 7.4 g/s. The two surveys yielded a
similar range of methane flux values, with the highest flux values occurring when the prevailing wind
direction was closest to normal to the plane of the VRPM configuration.

Figure B-7 present a time series of the calculated downwind methane flux values from the area and the
prevailing wind direction (from normal to the plane of the VRPM configuration), from the May 5 Boreal OP-
TDLAS survey.
                                                                                                    B-5

-------
                   0    20    40    60    80    100   120   140    160
                                     Cycle Number
            Figure B-7.  Time series of wind direction and methane flux values from the May 5
                       VRPM survey of Survey Area #2 using the Boreal OP-TDLAS
The downwind methane flux values from the survey ranged from .93 g/s to 24 g/s with an average value of
7.3 g/s. At times, the prevailing wind directions during the time of this survey were relatively far from normal
to the VRPM plane. However, the average methane flux value from this survey was comparable to the
average values from the May 4 VRPM surveys of this area, which were conducted during more favorable
wind conditions (prevailing winds were comparatively closer to normal to the VRPM plane).

Closed Site

HRPM Results

An HRPM survey was conducted in Survey Area #1 on May 2, using twelve optical paths. Figure B-8
presents the average reconstructed methane surface concentration contour map. The blue lines show the
locations of the optical paths, converging at the location of the OP-FTIR instrument.
                                                                                                     B-6

-------
               \
                             20    40    60    80    100    120   140   160    180
               Figure B-8.  Average Methane Surface Concentration Contour Map from
                          the May 2 HRPM Survey of Area #1 (concentrations shown
                          are in ppm above background)
The figure shows the presence of a methane emissions hot spot (having concentrations over 8 ppm above
atmospheric background levels) located in the western portion of the survey area. The survey detected an
additional hot spot in the northeastern portion of the survey area (having concentrations of approximately 4
ppm above atmospheric background).

HRPM surveys were conducted in Survey Area #2 on May 3 and May 5. Figures B-9 and B-10 show the
average reconstructed methane surface concentration contour maps from the May 3 and May 5 surveys,
respectively. The blue lines show the locations of the optical paths, converging at the location of the OP-
FTIR instrument.
                                                                                                    B-7

-------
                              0    20   40   60   60   100   120  140   160
                   Figure B-9.  Average Methane Surface Concentration Contour Map
                              from the May 3 HRPM Survey of Area #2 (concentrations
                              shown are in ppm above background)
The May 3 HRPM survey (see Figure B-9) detected a hot spot (concentrations greater than 36 ppm above
atmospheric background levels) in the eastern portion of the survey area. An additional methane hot spot
having concentrations greater than 5 ppm above atmospheric background levels was detected near the
northwestern corner of the survey area.
                                                                                                    B-8

-------
                           160
                                  20    40    60    W   100    120   140
                 Figure B-10.  Average Methane Surface Concentration Contour Map
                             from the May 5 HRPM Survey of Area #2 (concentrations
                             shown are in ppm above background)
The May 5 HRPM survey (see Figure B-10) detected a methane hot spot having concentrations greater
than 8 ppm above atmospheric background levels in the northeastern portion of the survey area. The survey
detected an additional hot spot near the center of the survey area having concentrations greater than 11
ppm above atmospheric background.

VRPM Results

On May 3, VRPM surveys were conducted along the eastern side of Survey Area #2 (measuring emissions
from both survey areas). Two surveys were conducted concurrently, using the IMACC OP-FTIR and the
Unisearch OP-TDLAS. Figures B-11 and B-12 present a time series of the calculated downwind methane
flux values from the area and the prevailing wind direction (from normal to the plane of the VRPM
configuration), from the May 3 IMACC OP-FTIR and Unisearch OP-TDLAS surveys, respectively.
                                                                                                  B-9

-------
                140
                                       10         15

                                    Cycle Number
          Figure B-11.  Time series of wind direction and methane flux values from the May 3
                      VRPM survey using the IMACC OP-FTIR


c
t GO -
E
1
S 30-
E ^3
9 f.
on .
E JU
1
o 10 -
E
5 n -
T3 U
i '
10 -



r\
. ^ \
\
\ „ "~~~\
'J\
A/ ;
\ /A.
) 5 v-AlO 15 W°/\/ 2S 3
\ _-_ A Vp-^
\7 VV
Cycle Number


- 35
- 30
-25 5
3
^ 	 Wind Direction
-20 ^
J — Methane Flux
- 15 I
- 10
0
-5


           Figure B-12.  Time series of wind direction and methane flux values from the May 3
                       VRPM survey using the Unisearch OP-TDLAS
On May 4, a VRPM survey was conducted along the southern side of the closed site (measuring emissions
from both survey areas).
                                                                                                    B-10

-------
                                       Cycle Number
              Figure B-13.  Time series of wind direction and methane flux values from the May 4
                         VRPM survey using the Unisearch OP-TDLAS
The downwind methane flux values from the May 4 survey (see Figure B-13) ranged from 3.1 g/s to 55 g/s
with an average of 12 g/s. In general, the highest flux values occurred when the prevailing winds were
closest to normal to the VRPM plane.

VOC and Ammonia Measurements

All datasets from the HRPM and VRPM surveys from the active and closed site were searched for the
presence of VOCs, air toxics, and other pollutants found in landfill gas. The analysis did not detect the
presence of any compounds at concentrations above the minimum detection levels (MDL) of the OP-FTIR
instruments.

Summary of the Measurement Campaign

ARCADIS and EPA conducted a field campaign in May 2005 at the Orange County Municipal Landfill,
located near Chapel Hill, North Carolina. The study used measurements from OP-FTIR and  OP-TDLAS
instruments and the RPM method to characterize fugitive emissions of methane and VOCs from the active
and closed areas at the site.

The HRPM survey conducted on May 2 in  Survey Area #1 of the active area detected the presence of a
methane hot spot, having concentrations greater than 6 ppm above background, located in the northern
portion of the site. The location of the hot spot was close to the active work face area.

HRPM surveys were conducted on May 3-5 in Survey Area #2 of the active area.  The May 3 and May 4
surveys detected a methane hot spot in the northern portion of the area having concentrations of 6 ppm
above background (May 3 survey), and 12 ppm above background (May 4 survey). The May 4 and May 5
surveys detected a methane hot spot along the western boundary of the area having concentrations of 12
ppm above background (May 4 survey), and 7 ppm above background (May 5 survey).
                                                                                                B-11

-------
VRPM surveys were conducted on May 4 and May 5 in Survey Area #2 of the active area. Two VRPM
surveys were completed on May 4 using an IMACC OP-FTIR and a Boreal OP-TDLAS. The average
methane flux from the May 4 surveys was 9.8 g/s (IMACC OP-FTIR), and 7.4 g/s (Boreal OP-TDLAS). The
average methane flux from the May 5 survey was 7.3 g/s.

An HRPM survey was conducted on May 2 in Survey Area #1 of the closed area. The survey detected a
methane hot spot having concentrations greater than 8 ppm above background in the western portion of the
area. An additional hot spot, having concentrations greater than 4 ppm above background was found in the
northeastern corner of the area.

HRPM surveys were conducted on May 3 and May 5 in Survey Area #2 of the closed area. The May 3
survey found methane hot spots in the eastern portion  of the area (concentrations greater than 36 ppm
above background), and northwestern corner of the area (concentrations greater than 5 ppm above
background). The May 5 survey detected a methane hot spot (concentrations greater than 8 ppm above
background) in the  northeastern corner of the area, and a methane  hot spot (concentrations greater than 11
ppm above background) near the center of the survey area.

Two VRPM surveys were conducted on May 3 along the  eastern border of the closed area using an IMACC
OP-FTIR and Unisearch OP-TDLAS. The surveys found an average methane flux of 22 g/s (IMACC OP-
FTIR), and 10  g/s (Unisearch OP-TDLAS). A VRPM survey was conducted on May 4 along the southern
boundary of the closed a7rea. The average methane flux from this survey was 12 g/s.

The datasets from the HRPM and VRPM surveys of both areas were searched for the presence of VOCs,
air toxics, and  other pollutants found in  landfill gas. The analysis did not detect the presence of any
compounds at concentrations greater than the MDL of the OP-FTIR instruments.
                                                                                               B-12

-------
    Appendix C: Methane Emissions Results from the VRPM Validation Study Conducted During
                                      June and July, 2006

The following sections present data on methane emissions from the Closed Area of the Orange County
Municipal Landfill collected during the VRPM Validation Study. The collection of this data was considered
non-critical for the study, and was done to provide further information on methane emissions from landfill
sites. Methane concentration data was collected during the following days of the study: June 16th during the
20 meter sulfur hexafluoride release, June 19th during the 100 meter sulfur hexafluoride release, July 5th
during the 140  meter sulfur hexafluoride release, and July 7th during the 60 meter sulfur hexafluoride
release. However, data from June 16th was not analyzed because a post-analysis of the wind data indicated
that the prevailing winds during this day were highly variable, and not sufficient to obtain reliable methane
flux values through the VRPM configuration. The methane flux values presented were measured along the
longest VRPM  configuration used in the study.

Methane Flux  Values Determined During the June 19 Release

Figure  C-1 presents the average reconstructed methane plume map from all of the data  collection cycles on
June 19. The average calculated methane flux value was 16 grams per second.

Figure  C-2 presents a time series of the calculated methane flux values and the prevailing wind direction
(from normal to the plane of the VRPM configuration), from the June 19 measurements.

The calculated methane fluxes ranged from 6.1 to 33 grams per second. The highest methane flux values
were observed during periods that the prevailing winds were closest to perpendicular to the VRPM
configuration.
                                                                                                    C-1

-------
  22



  20



  18



  16
I"
r 12


fio


   8


   6


   4


   2
Concentrations are in ppm
Flux= 16.46g/s
          20     40
                       60
                              80     100     120    140

                            Crosswind Distance [meters]
                                                         160    180     200
 Figure C-1. Reconstructed Methane Plume Map from the June 19 Measurements
                                                                                                C-2

-------
        35
           1  47101316 19 22 25 28 31 34 37 40 43 46 49 52 55
                                Cycle Number
                                                                             -Methane Flux
                                                                             -Wind Direction
Figure C-2. Time series of wind direction and methane flux values from the June 19 VRPM survey.
                                                                                                         C-3

-------
Methane Flux Values Determined During the July 5 Release

Figure C-3 presents the average reconstructed methane plume map from all of the data collection cycles on
July 5. The average calculated methane flux value was 29 grams per second

Figure C-4 presents a time series of the calculated methane flux values and the prevailing wind direction
(from normal to the plane of the VRPM configuration), from the July 5 measurements.

The calculated methane fluxes ranged from 18 to 54 grams per second. In general, there was no observed
correlation between methane flux values, and  prevailing wind direction  during the time of the
measurements.
         22

         20

         18

         16
       I
       I 10
Concentrations are in ppm
Flux = 29.35 gfe
                20     40     60     60     100    120    140
                                  Crosswind Distance [meters]
                                                             160
                                                                    180
                                                                          200
            Figure C-3. Reconstructed methane plume map from the July 5 measurements.
                                                                                                      C-4

-------
                                                          350
                                                          300
        1   4  7 10  13  16  19  22 25 28 31 34 37 40  43  46
                          Cycle Number
                                                                       -Methane Flux
                                                                       • Wind Direction
Figure C-4. Time series of wind direction and methane flux values from the July 5 VRPM survey.
                                                                                                  C-5

-------
Methane Flux Values Determined During the July 7 Release

Figure C-5 presents the average reconstructed methane plume map from all of the data collection cycles on
July 7. The average calculated methane flux value was 13 grams per second

Figure C-6 presents a time series of the calculated methane flux values and the prevailing wind direction
(from normal to the plane of the VRPM configuration), from the July 7 measurements.

The calculated methane fluxes ranged from 6.3 to 24 grams per second. In general, the highest methane
flux values were observed during  periods that the prevailing winds were closest to perpendicular to the
VRPM configuration.
               22

               20

               18

               16
               *
             2 io

                6

                6

                4

                2
   Concentrations are in ppm
   Flux = 13-23 g/s
--0.944
                       20     40
                                   60    80    100    120    140    160    180
                                        Crosswind Distance [meters]
                                                                               200
              Figure C-5. Reconstructed methane plume map from the July 7 measurements.
                                                                                                      C-6

-------
     25
         1357 91113151719212325272931333537
                           Cycle Number
                                                                      -Wind Direction
                                                                      -Methane Flux
Figure C-6.  Time series of wind direction and methane flux values from the July 7 VRPM survey.
                                                                                              C-7

-------
Appendix D: ORS Instrument Manufacturers
Company Name
Industrial Monitoring &
Control Corporation
(IMACC)
Midac Corporation
AIL, Inc. c/o Kassay
Field Services
Boreal Laser, Inc.
OPSIS, Inc.
Cerex Scientific
Unisearch Associates,
Inc.
Instrumentation
OP-FTIR
OP-FTIR
OP-FTIR
OP-TDLAS
UV-DOAS
UV-DOAS
OP-FTIR/ OP-
TDLAS
Address
800 Paloma Dr.Ste 100 Round
Rock, TX 78664
130 McCormickAve.#111 Costa
Mesa, CA 92626
Not Available
#13 511 27 RR255 Spruce
Grove, AB CANADA T7Y1 A8
1 165 Linda Vista Dr., Ste 112
San Marcos, CA 92069
1701 Barrett Lakes Blvd.Ste 200
Kennessaw, GA30144
96 Bradwick Drive Concord,
Ontario CANADA L4K1k8
Telephone
(512)341-8189
(714)546-4322
(610)916-8988
(780) 987-4382
(760) 752-3006
(678)819-3766
(905) 669-3547
                                                                 D-1

-------