Environmental Technology Verification

         Baghouse Filtration Products
              Donaldson Company, Inc.
              tratex® 6262 Filtration Med
               (Tested March 2011)
                 Prepared by

           RTI International and ETS Incorporated
HRTI
INTERNATIONAL
           Under a Cooperative Agreement with
           U.S. Environmental Protection Agency
                 EPA

-------
Environmental Technology Verification Report

          Baghouse Filtration Products
                   Donaldson Company, Inc.
                 Tetratex® 6262 Filtration Media
                     (Tested March 2011)
                        Prepared by

                      RTI International
                      ETS Incorporated
            EPA Cooperative Agreement CR 83416901-0
                     EPA Project Officer
                      Michael Kosusko
           Air Pollution Prevention and Control Division
          National Risk Management Research Laboratory
               Office of Research and Development
              U.S. Environmental Protection Agency
                Research Triangle Park, NC 27711

-------
 THE  ENVIRONMENTAL TECHNOLOGY VERIFICATION
                              PROGRAM
HRTI
INTERNATIONAL
                               '3*71
                               L
               ETV Joint Verification Statement
  TECHNOLOGY TYPE:

  APPLICATION:

  TECHNOLOGY NAME:

  COMPANY:

  ADDRESS:
  WEB SITE:

  E-MAIL:
BAGHOUSE FILTRATION PRODUCTS

CONTROL OF PM2.5 EMISSIONS BY BAGHOUSE
FILTRATION PRODUCTS
Tetratex® 6262 Filtration Media
Donaldson Company, Inc.
85 Railroad Dr.
Ivyland, PA 18974
PHONE: (215)396-8349
FAX: (215)396-0516
http://www.donaldson.com
Anil.Suthar@Donaldson.com
Karen.Bentley@Donaldson.com
The U.S. Environmental Protection Agency (EPA) created the Environmental Technology Verification
(ETV) Program to facilitate the deployment of innovative or improved environmental technologies
through performance verification and dissemination of information. The goal of the ETV Program is to
further environmental protection by accelerating the acceptance and use of improved and cost-effective
technologies. The ETV Program seeks to achieve this goal by providing high-quality, peer-reviewed data
on technology performance to those involved in the design, distribution, financing, permitting, purchase,
and use of environmental technologies.

The ETV Program works in partnership with recognized standards and testing organizations; stakeholder
groups, which consist of buyers, vendor organizations, permitters, and other interested parties; and with
the full participation of individual technology developers. The program evaluates the performance of
innovative technologies by developing test plans that are responsive to the needs of stakeholders,
conducting field or laboratory tests (as appropriate), collecting and analyzing data, and preparing peer-
reviewed reports. All evaluations are conducted in accordance with rigorous quality assurance (QA)
protocols to ensure that data of known and adequate quality are generated and that the results are
defensible.

-------
The Air Pollution Control Technology Center (APCT Center) is operated by RTI International* (RTI), in
cooperation with EPA's National Risk Management Research Laboratory (NRMRL). The APCT Center
evaluates the performance of baghouse filtration products (BFPs) used primarily to control PM2 5
emissions (i.e., particles 2.5 urn and smaller in aerodynamic diameter). This verification statement
summarizes the test results for Donaldson Company, Inc.'s Tetratex 6262 filtration media.

VERIFICATION TEST DESCRIPTION

All tests were performed in accordance with the APCT Center Generic Verification Protocol for
Baghouse Filtration Products, available athttp://www.epa.gov/etv/pubs/05_vp_bfp.pdf The protocol is
based on and describes modifications to the equipment and procedures described in Verein Deutscher
Ingenieure (VDI) 3926, Part 2, Testing of Filter Media for Cleanable Filters under Operational
Conditions, December 1994. The VDI document is available from Beuth Verlag GmbH, 10772 Berlin,
Germany. The protocol also includes requirements for quality management and QA,  procedures for
product selection, auditing of the test laboratories, and the test reporting  format.

Outlet particle concentrations from a test fabric were measured with an impactor equipped with
appropriate substrates to filter and measure PM2 5 within the dust flow. Outlet particle concentrations were
determined by weighing the mass increase of dust collected in each impactor filter stage and dividing by
the gas volumetric flow through the impactor.

Particle size was measured while injecting the test dust into the air upstream of the baghouse filter
sample. The test dust was dispersed into the flow using a brush-type dust feeder. The particle size
distributions in the  air were determined both upstream and downstream of the test filter fabric to provide
accurate results for penetration through the test filter of PM2 5. All tests were performed using a constant
18.4 ± 3.6 g/dscm (8.0 ± 1.6 gr/dscf) loading rate, a 120 ± 6.0 m/h (6.6 ± 0.3 fpm) filtration velocity
[identical to gas-to-cloth ratio (G/C**)], and aluminum oxide test dust with a measured mass mean
aerodynamic diameter maximum of 1.5 urn (average of three impactor runs). All BFPs are tested in their
initial (i.e.,  clean) condition.

Each of the three test runs consisted of the following segments:

    •    Conditioning period—10,000 rapid-pulse cleaning cycles

    •   Recovery period—30 normal-pulse cleaning cycles

    •   Performance test period—6-hour filter fabric test period with impactor.

VERIFIED TECHNOLOGY DESCRIPTION

Donaldson Company, Inc. provided the following information about their product. The Donaldson
Tetratex 6262 is an ePTFE laminate on PPS. Figure  1 is a photograph of the fabric. Sample material was
received as nine 46 x 91 cm (18x36 in.) swatches marked with the manufacturer's model number, year
and month of manufacture, and cake side. Three of the swatches were selected  at random for preparing
three test specimens 150 mm (5.9 in.) in diameter.
 RTI International is a trade name of Research Triangle Institute.
 Filtration velocity and gas-to-cloth ratio are used interchangeably and are defined as the gas flow rate divided by the surface
   area of the cloth.

-------
        Donaldson Company, Inc.
        PC# 6262
        ePTFE Laminate on PPS
    Figure 1. Photograph of Donaldson Company, Inc.'s Tetratex 6262 filtration media.

VERIFICATION OF PERFORMANCE

Verification testing of the Donaldson Company, Inc.'s Tetratex 6262 filtration media was performed
during the period of March 9, 2011, to March 16, 2011, for standard test conditions at the test facility of
ETS Incorporated, 1401 Municipal Road NW, Roanoke, VA 24012. Test conditions are listed in Table 1.
The overall test results summarized in Table 2 represent the averages of three individual tests.

The APCT Center quality manager has reviewed the test results and the quality control (QC) data and has
concluded that the data quality objectives given in the generic verification protocol and test/QA plan have
been attained.

This verification statement addresses five aspects of filter fabric performance: filter outlet PM2 5
concentration, filter outlet total mass concentration, pressure drop, filtration cycle time, and mass gain on
the filter fabric. Users may wish to consider other performance parameters, such as temperature, service
life, and cost when selecting a filter fabric for their application.

         Table 1. Test Conditions for Baghouse Filtration Products Brand/Model:
               Donaldson Company, Inc.'s Tetratex 6262 Filtration Media
Test Parameter
Dust concentration
Filtration velocity (G/C)
Pressure loss before cleaning
Tank pressure
Value
18.4 ± 3.6 g/dscm (8.0 ± 1 .6 gr/dscf)
120±6m/h(6.6±0.3fpm)
1, 000 ±12 Pa (4 ±0.05 in. w.g.)
0.5 ± 0.03 MPa (75 ± 5 psi)

-------
         Table 1. Test Conditions for Baghouse Filtration Products Brand/Model:
          Donaldson Company, Inc.'s Tetratex 6262 Filtration Media (continued)
Test Parameter
Valve opening time
Air temperature
Relative humidity
Total raw gas stream flow rate
Sample gas stream flow rate
Number of cleaning cycles
During conditioning period
During recovery period
Performance test duration
Value
50 ± 5 ms
25 ± 2 °C (77 ± 4 °F)
50 ± 1 0%
5.8 ± 0.3 m3/h (3.4 ± 0.2 cfm)
1.13 ± 0.06 m3/h (0.67 ± 0.03 cfm)
—
10,000 cycles
30 cycles
6h±1 s
          Table 2. Baghouse Filtration Product Three-Run Average Test Results
              for Donaldson Company, Inc.'s Tetratex 6262 Filtration Media
Verification Parameter
Outlet particle concentration at standard conditions3
PM2 5, g/dscm
(gr/dscf)
Total mass, g/dscmb
(gr/dscf)
Average residual pressure drop (A P), cm w.g. (in. w.g.)
Initial residual A P, cm w.g. (in. w.g.)
Residual A P increase, cm w.g. (in. w.g.)
Filtration cycle time, s
Mass gain of test sample filter, g (gr)
Number of cleaning cycles
At Verification Test Conditions
<0.0000167C
(<0.0000073)
<0. 0000167°
(<0.0000073)
3.14(1.23)
3.05 (1 .20)
0.16(0.06)
179
0.17(2.67)
120
a Standard conditions: 101.3 kPa (14.7 psia) and 20 °C (68 °F). One or more of the impactor substrate
  weight changes for these results were near the reproducibility of the balance.
b Total mass includes the mass of PM2 5 and larger particles that passed through the fabric.
c The measured value was determined to be below the detection limit of 0.0000167 grams per cubic
  meter. The detection limit is for a 6-hour test and based on VDI 3926.

-------
In accordance with the generic verification protocol, this verification statement is applicable to filter
media manufactured between the signature date of the verification statement and 3 years thereafter.
Signed by Sally Gutierrez, Director                                         Date: 7/19/2011
National Risk Management Research Laboratory
Office of Research and Development
United States Environmental Protection Agency
Signed by Jason Hill, Director                                              Date: 6/30/2011
Air Pollution Control Center
RTI International
  NOTICE: ETV verifications are based on an evaluation of technology performance under specific,
  predetermined criteria and the appropriate quality assurance procedures. EPA and RTI make no express or
  implied warranties as to the performance of the technology and do not certify that a technology will
  always operate as verified. The end user is solely responsible for complying with any and all applicable
  federal, state, and local requirements. Mention of commercial product names does not imply endorsement.

-------
Environmental Technology Verification Report                Donaldson Company, Inc. Tetratex 6262
                                         Notice

This document was prepared by RTI International* (RTI) and its subcontractor ETS Incorporated (ETS)
with partial funding from Cooperative Agreement No. CR 83416901-0 with the U.S. Environmental
Protection Agency (EPA). The document has been subjected to RTI/EPA's peer and administrative
reviews and has been approved for publication. Mention of corporation names, trade names, or
commercial products does not constitute endorsement or recommendation for use of specific products.
 RTI International is a trade name of Research Triangle Institute.

-------
Environmental Technology Verification Report                Donaldson Company, Inc. Tetratex 6262
                                       Foreword

The Environmental Technology Verification (ETV) Program, established by the U.S. Environmental
Protection Agency (EPA), is designed to accelerate the development and commercialization of new or
improved technologies through third-party verification and reporting of performance. The goal of the
ETV Program is to verify the performance of commercially ready environmental technologies through the
evaluation of objective and quality-assured data in order to provide potential purchasers and permitters an
independent, credible assessment of the technology that they are buying or permitting.

The Air Pollution Control Technology Center (APCT Center) is part of the EPA's ETV Program and is
operated as a partnership between RTI International (RTI) and EPA. The APCT Center verifies the
performance of commercially ready air pollution control technologies. Verification tests use approved
protocols, and verified performance is reported in verification statements signed by EPA and RTI
officials. RTI contracts with  ETS Incorporated (ETS) to perform verification tests on baghouse filtration
products, including filter media.

Baghouses are air pollution control  devices used to control particulate emissions from stationary sources
and are among the technologies evaluated by the APCT Center. The APCT Center developed (and EPA
approved) the Generic Verification  Protocol for Baghouse Filtration Products to provide guidance on
these verification tests.

The following report reviews the performance of Donaldson Company, Inc.'s  Tetratex® 6262 filtration
media. ETV testing of this technology was conducted during March 2011 at ETS. All testing was
performed in accordance with an approved test/quality assurance  (QA) plan that implements the
requirements of the generic verification protocol at the test laboratory.

-------
Environmental Technology Verification Report              Donaldson Company, Inc. Tetratex 6262
     Availability of Verification Statement and Report


Copies of this verification report are available from the following:

   •  RTI International
      Discovery and Analytical Sciences
      P.O. Box 12194
      Research Triangle Park, NC 27709-2194

   •  U.S. Environmental Protection Agency
      Air Pollution Prevention and Control Division (E343-02)
      109 T. W. Alexander Drive
      Research Triangle Park, NC 27711

Web Site: http://www.epa.gov/etv/vt-apc.html (electronic copies)
                                         in

-------
Environmental Technology Verification Report                Donaldson Company, Inc. Tetratex 6262

                                   Table of Contents
Notice	i
Foreword	ii
Availability of Verification Statement and Report	iii
List of Abbreviations and Acronyms	vi
Acknowledgments	viii
1.0   Introduction	1
2.0   Verification Test Description	2
      2.1   Description of the Test Rig and Methodology	2
      2.2   Selection of Filtration Sample for Testing	4
      2.3   Control Tests	4
      2.4   Analysis	5
3.0   Description of Filter Fabric	8
4.0   Verification of Performance	9
      4.1   Quality Assurance	9
      4.2   Results	9
      4.3   Limitations and Applications	10
5.0   References	11
                                              IV

-------
Environmental Technology Verification Report                Donaldson Company, Inc. Tetratex 6262
                                    List of Figures

Figure 1.  Diagram of filtration efficiency media analyzer test apparatus	
Figure 2.  Photograph of Donaldson Company, Inc.' s Tetratex 6262 filtration media	
                                     List of Tables


Table 1.  Summary of Control Test Results	5
Table 2.  Summary of Verification Results for Donaldson Company, Inc.'s Tetratex 6262
         Filtration Media	10

-------
Environmental Technology Verification Report
Donaldson Company, Inc. Tetratex 6262
               List of Abbreviations and Acronyms
APCT Center      Air Pollution Control Technology Center




BFP             baghouse filtration product




cfm              cubic feet per minute




cm               centimeters




cm w.g.           centimeters of water gauge




dia.              diameter




AP               pressure drop




dscmh            dry standard cubic meters per hour




EPA             U.S. Environmental Protection Agency




ETS             ETS Incorporated




ETV             Environmental Technology Verification




FEMA           filtration efficiency media analyzer




fprn              feet per minute




g                grams




g/dscm           grams per dry standard cubic meter




g/m3             grams per cubic meter




G/C              gas-to-cloth ratio (filtration velocity)




gr               grains




gr/dscf           grains per dry standard cubic foot




GVP             generic verification protocol




h                hours




in.               inches




in. w.g.           inches of water gauge




kPa              kilopascals




m               meters






                                          vi

-------
Environmental Technology Verification Report                Donaldson Company, Inc. Tetratex 6262
m/h               meters per hour




m3/h              cubic meters per hour




mbar             millibars




min.              minutes




mm               millimeters




MPa              megapascals




ms               milliseconds




NA               not applicable




Pa                pascals




PM               particulate matter




PM2 5             particulate matter 2.5 micrometers in aerodynamic diameter or smaller




psi               pounds per square inch




psia               pounds per square inch absolute




QA               quality assurance




QC               quality control




RTI               RTI International




s                 seconds




scf               standard cubic feet




t                 time




VDI              Verein Deutscher Ingenieure




w.g.               water gauge




um               micrometers




 C                degrees Celsius




 F                degrees Fahrenheit




 R               degrees Rankine
o
                                              Vll

-------
Environmental Technology Verification Report                Donaldson Company, Inc. Tetratex 6262
                             Acknowledgments
The authors acknowledge the support of all those who helped plan and conduct the verification activities.
In particular, we would like to thank Michael Kosusko, U.S. Environmental Protection Agency's (EPA's)
Project Officer, and Bob Wright, EPA's Quality Manager, who both work as part of EPA's National Risk
Management Research Laboratory in Research Triangle Park, NC. Finally, we would like to acknowledge
the assistance and participation of Donaldson Company, Inc. personnel, who supported the test effort.

For more information on Donaldson Company, Inc.'s Tetratex 6262, contact the following:

   •   Anil Suthar
       Donaldson Company, Inc.
       85 Railroad Drive
       Ivyland, PA 18974
       (215) 396-8349
       Anil. Suthar@Donaldson. com
       Or

   •   Karen Bentley
       Donaldson Company, Inc.
       85 Railroad Drive
       Ivyland, PA 18974
       (215) 396-8349
       Karen.Bentley@Donaldson.com

For more information on verification testing of baghouse filtration products, contact the following:

   •   Jason Hill
       RTI International
       P.O. Box 12194
       Research Triangle Park, NC 27709-2194
       (919)541-7443
       APCTVC@rti.org
                                           Vlll

-------
Environmental Technology Verification Report                Donaldson Company, Inc. Tetratex 6262
1.0    Introduction

This report reviews the pressure drop (AP) and filtration performance of Donaldson Company, Inc.'s
Tetratex® 6262 filtration media. Environmental Technology Verification (ETV) testing of this
technology/product was conducted during a series of tests in March 2011 by ETS Incorporated (ETS),
under contract with the Air Pollution Control Technology Center (APCT Center). The objective of the
APCT Center and the ETV Program is to verify, with high data quality, the performance of air pollution
control technologies. Control of fine-particle emissions from various industrial and electric utility sources
employing baghouse control technology is within the scope of the APCT Center. An APCT Center
program area was designed by RTI International (RTI) and a technical panel of experts to evaluate the
performance of particulate filters for fine-particle (i.e., PM2 5)  emission control. Based on the activities of
this technical panel, the Generic Verification Protocol for Baghouse Filtration Products was developed.
This protocol was chosen  as the best guide to verify the filtration performance of baghouse filtration
products (BFPs). The specific test/quality assurance (QA) plan for the ETV test of the technology was
developed and approved in May 2000, followed by an approved update  in February 2006. The goal of the
test was to measure filtration performance of both PM2 5 and total particulate matter (PM), as well as the
AP characteristics of the Donaldson Company, Inc. technology identified above.

Section 2 of this report documents the procedures used for the test and the conditions over which the test
was conducted. A description of Donaldson Company, Inc.'s Tetratex 6262 filtration media is presented
in Section 3. The results of the test are summarized and discussed in Section 4, and references are
presented in Section 5.

This report contains summary information and data from the test and the verification statement. Complete
documentation of the test  results is provided in a separate data package report and an audit of data quality
report. These reports include the raw test data from product testing and supplemental testing, equipment
calibrations results, and QA and quality control (QC) activities and results. Complete documentation of
QA/QC activities and results, raw test data, and equipment calibrations results are retained in ETS's files
for 7 years.

-------
Environmental Technology Verification Report                 Donaldson Company, Inc. Tetratex 6262
2.0    Verification Test Description

The BFPs were tested in accordance with the APCT Center Generic Verification Protocol for Baghouse
Filtration Products1 and the Test/QA Plan for the Verification Testing of Baghouse Filtration Products.2
These documents incorporate all the requirements for quality management, QA, procedures for product
selection, auditing of the test laboratories, and reporting format. The Generic Verification Protocol (GVP)
describes the overall procedures used for verification testing and defines the data quality objectives. The
values for inlet dust concentration, raw gas flow rate, and filtration velocity used for current verification
testing have been revised in consultation with the technical panel since posting of the GVP. These
revisions are documented in Section 4.1. The test/QA plan details how the test laboratory at ETS
implemented and met the requirements of the GVP.

2.1    Description of the Test Rig and Methodology

The tests were conducted in ETS's filtration efficiency media analyzer (FEMA) test apparatus (Figure 1).
The test apparatus consists of a brush-type dust feeder that disperses test dust into a vertical rectangular
duct (raw-gas channel). The dust feed rate is continuously measured and recorded via an electronic scale
located beneath the dust feed mechanism. The scale has a continuous readout with a resolution of 10 g. A
radioactive polonium-210 alpha source is used to neutralize the dust electrically before its entry into the
raw-gas channel. An optical photo sensor monitors the concentration of dust and ensures that the flow is
stable for the entire duration of the test. The optical photo sensor does not measure absolute
concentration, and is, therefore, not the primary concentration measurement for the test. A portion of the
gas flow is extracted from the raw-gas channel through the test filter, which is mounted vertically at the
entrance to a horizontal duct (clean-gas channel). The clean-gas channel flow is separated in two gas
streams, a sample stream and a bypass stream. An aerodynamic "Y" is used for this purpose. The
aerodynamic "Y" is designed for isokinetic separation of the clean gas with 40% of the clean gas entering
the sample-gas channel without change in gas velocity. The sample-gas channel contains an Andersen
impactor for particle separation and measurement. The bypass channel contains an absolute filter. The
flow within the two segments of the 'Y"" is continuously monitored and maintained at selected rates by
adjustable valves. Two vacuum pumps maintain air flow through the raw-gas and clean-gas channels. The
flow rates, and thus the gas-to-cloth ratio (G/C) through the test filter, are kept constant and measured
using mass flow controllers. A pressure transducer is used to measure the average residual AP of the filter
sample. The pressure transducer measures the differential pressure across the filter samples  every 3
seconds; the residual AP measurements are those taken 3 seconds after the cleaning pulse. The AP
measurements are then averaged, as described in Appendix C,  Section 4.4.1 of the GVP.1 High-efficiency
filters are installed upstream of the flow controllers and pumps to prevent contamination or damage
caused by the dust. The cleaning system consists of a compressed-air tank set at 0.5 MPa (75 psi), a
quick-action diaphragm valve, and a blow tube [25.4 mm (1.0 in.) dia.] with a nozzle [3 mm (0.12 in.)
dia.] facing the downstream side of the test filter.

Mean outlet particle concentration is determined when a portion of the gas flow is extracted from the raw-
gas channel through the test filter, which is mounted vertically at the entrance to a horizontal duct (clean-
gas channel). The clean-gas flow is separated using an aerodynamic 'Y"" so that a representative sample
of the clean gas flows through an Andersen impactor that determines the outlet particle concentration.
Outlet particle concentrations were determined by weighing the mass increase of dust collected in each
impactor filter stage and dividing by the gas volumetric flow through the impactor.

The particle size  was  measured while a fine dust was injected into the air stream upstream of the filter
fabric sample.  The particle size distributions in the air were determined both upstream and downstream  of
the test filter fabric to provide accurate results for penetration through the test filter of PM2 5.

-------
Environmental Technology Verification Report
Donaldson Company, Inc. Tetratex 6262
                                                   DUST FEED FROM EXTERNAL HOPPER

                                                   DUST CHARGE NEUTRALIZER


                                                   RECTANGULAR CHANNEL
                                                   111 x 292 mm (4-3/8 x 11-1/2")
                                                   PHOTOMETER

                                                   FILTER FIXTURE AND TEST FILTER

                                                   CYLINDRICAL EXTRACTION TUBE

                                                   CLEAN-GAS SAMPLE PORT

                                                   RAW-GAS SAMPLE PORT

                                                   CLEANING SYSTEM
                                                                            BACKUP
                                                                            FILTER
                                                                                MASS FLOW
                                                                                CONTROLLER
                                                   ABSOLUTE FILTER AND
                                                   ANDERSENIMPACTOR
          ADJUSTABLE
            VALVES
                                                                         CALIBRATED
                                                                         ORIFICE
                                                              BLOW TUBE
                                                              DIRTY AIR
                                                              FILTER
                                                                      CLEAN AIR PUMP
                                                         MASS FLOW
                                                        CONTROLLER
               DIRTY AIR
                 PUMP
                                DUST
                                CONTAINER
          Figure 1. Diagram of filtration efficiency media analyzer test apparatus.

-------
Environmental Technology Verification Report                 Donaldson Company, Inc. Tetratex 6262
The following series of tests was performed on three separate, randomly selected filter fabric samples:

    •   Conditioning period

    •   Recovery period

    •   Performance test period.

To simulate long-term operation, the test filter was first subjected to a conditioning period, which consists
of 10,000 rapid-pulse cleaning cycles under continuous dust loading. During this period, the time between
cleaning pulses was maintained at 3 seconds. No filter performance parameters are measured in this
period.

The conditioning period is immediately followed by a recovery period, which allowed the test filter fabric
to recover from rapid pulsing. The recovery period consists of 30 normal filtration cycles under
continuous and constant dust loading. During  a normal filtration cycle, the dust cake is allowed to form
on the test filter until a differential pressure of 1,000 Pa (4.0 in. w.g.) is reached. At this point, the test
filter is cleaned by a pulse of compressed air from the clean-gas side of the fabric. The next filtration
cycle begins immediately after the cleaning is complete.

Performance testing occurred for a 6-hour period immediately following the recovery period (a
cumulative total of 10,030 filtration cycles after the test filter had been installed in the test apparatus).
During the performance test period, normal filtration cycles are maintained and, as in the case of the
conditioning and recovery periods, the test filter is subjected to continuous and constant dust loading.

The filtration velocity (G/C) and inlet dust concentrations were maintained at 120 ± 6 m/h (6.6 ± 0.3 fpm)
and 18.4 ± 3.6 g/dscm (8.0 ±1.6 gr/dscf), respectively, throughout all phases of the test.

2.2    Selection of Filtration Sample for Testing

Filter fabric samples of Tetratex 6262 filtration media were supplied to ETS directly from the
manufacturer (Donaldson Company, Inc.), with a letter signed by Mark Rigby, general manager,
Donaldson Company, Inc., attesting that the filter media were selected at random in an unbiased manner
from commercial-grade media and were not treated in any manner different from the media provided to
customers. The manufacturer supplied the test laboratory with nine 46 x 91 cm (18 x 36 in.) filter
samples. The test laboratory randomly selected three samples and prepared them for testing by cutting one
test specimen of 150 mm (5.9 in.) diameter from each selected sample for insertion in the test rig sample
holder. The sample holder has an opening 140 mm (5.5 in.) in diameter, which is the dimension used to
calculate the face area of the tested specimen.

2.3    Control Tests

Two types of control tests were performed during the  verification test series. The first was a dust
characterization, which is performed monthly. The reference dust used during the verification tests was
Pural NF aluminum oxide dust. The Pural NF dust was oven dried for 2 hours and sealed in an airtight
container prior to its insertion into the FEMA apparatus. The criteria for the dust characterization test are
a maximum mass mean diameter of 1.5 ± 1.0  urn and  a concentration between 40% and 90% of particles
less than 2.5 (im. These criteria must be met in order to continue the verification test series.

The second control test, the reference value test, is performed quarterly using the reference fabric and the
FEMA apparatus. The reference value test determines the weight gain of the reference fabric, as well as
the maximum AP (final residual pressure drop). The results of the test verified that the FEMA apparatus

-------
Environmental Technology Verification Report
                                            Donaldson Company, Inc. Tetratex 6262
was operating consistently within the required parameters. The average fabric maximum AP (average of
the repeated measurements of final residual pressure drop conducted during the quarter applicable to this
test) in a reference value test must be 0.60 cm w.g. ± 40%, and the fabric weight gain average must be
1.12 g ± 40%. Three reference value control test runs were conducted. The results of the control tests are
summarized in Table 1.
                          Table 1. Summary of Control  Test Results
—
Mass mean diameter, |jm
% Less than 2.5 |jm
Weight gain, g
Maximum pressure drop, cm w.g.
Requirement
1.5 ±1.0
40%-90%
1.12 ±40%
0.60 ±40%
Measured Value
1.75
66.27%
0.88
0.40
Criteria Met
Yes
Yes
Yes
Yes
2.4    Analysis
The equations used for verification analysis are described below.
Af
Cds
C2.5ds
dia.
Fa
Fs
G/C
Mt
M2.5

N
"avg
P,
PS
Qa
Qds
Q2.5ds
Qst
t
to
Ts
Exposed area of sample filter, m2
Dry standard outlet particulate concentration of total mass, g/dscm
Dry standard outlet particulate concentration of PM25, g/dscm
Diameter of exposed area of sample filter, m
Dust feed concentration corrected for actual conditions, g/m3
Dust feed concentration corrected for standard conditions, g/dscm
Gas-to-cloth ratio, m/h
Total mass gain from Andersen impactor, g
Total mass gain of particles equal to or less than 2.5 urn diameter from Andersen
impactor, g.  This value may need to be linearly interpolated from test data.
Number of filtration cycles in a given performance test period
Average residual AP, cm w.g.
Residual AP for rth filtration cycle, cm w.g.
Absolute gas pressure as measured in the raw-gas channel, mbar
Actual gas flow rate, m3/h
Dry standard gas flow rate, dscmh
Dry standard gas flow rate for 2.5 urn particles, dscmh
Standard gas flow rate for a specific averaging time, t, dscmh
Specified averaging time or sampling time, s
Average filtration cycle time, s
Raw-gas channel temperature, °F

-------
Environmental Technology Verification Report
                                                         Donaldson Company, Inc. Tetratex 6262
wf
W;
              Weight of dust in feed hopper following specified time, g. Because of vibrations causing
              short-term fluctuations to the feed hopper, this value is measured as a 1-min. average.
       =      Weight of dust in feed hopper at the beginning of the specified time, g. Due to vibrations
              causing short-term fluctuations to the feed hopper, this value is measured as a 1-min.
              average.

Conversion factors and standard values used in the equations are listed below.
460    =      0 °F, in °R

1,013  =

528
              Standard atmospheric pressure, mbar

              Standard temperature, °R

Area of Sample Fabric, Af
        Af  =
Actual Gas Flow Rate, Qa

                   "(7;+460)*1013
                       P. * 528
Gas-to-Cloth Ratio, G/C
        C   A,

Standard Dust Feed Concentration, Fs, for a specified time, t

        p   W^Wf.
Actual Raw Gas Dust Concentration, F£

                  ~(7;+460)*1013"
        F=F*
                      P., * 528
Dry Standard Clean Gas Particulate Concentration, Total Mass, Cds

        C              M'
         *    \n     tfi   %H2O\
               ^ds*t*(     ioo~J

-------
Environmental Technology Verification Report
Donaldson Company, Inc. Tetratex 6262
Dry Standard Clean Gas Particulate Concentration, PM2.5j C2.>_


                         \A

        C7^=-
                               %H2O


                                100
Filtration Cycle Time, tc


             t
Average Residual Pressure Drop, Pavg
        p   -
         "'    N

-------
Environmental Technology Verification Report
Donaldson Company, Inc. Tetratex 6262
3.0   Description of Filter Fabric

The Donaldson Company, Inc. Tetratex 6262 is an ePTFE laminate on PPS. Figure 2 is a photograph of
the fabric. Sample material was received as nine 46 x 91 cm (18 x 36 in.) swatches marked with the
manufacturer's model number, year and month of manufacture, and cake side (the upstream side of the
fabric, which is exposed to the particle-laden air, on which the filter cake builds up). Three of the
swatches were selected at random for preparing three test specimens 150 mm (5.9 in.) in diameter.
        Donaldson Company, Inc
        PC# 6262
        ePTFE Laminate on PPS
   Figure 2. Photograph of Donaldson Company, Inc.'s Tetratex 6262 filtration media.

-------
Environmental Technology Verification Report                 Donaldson Company, Inc. Tetratex 6262
4.0    Verification of Performance

4.1    Quality Assurance

The verification tests were conducted in accordance with an approved test/QA plan.2 The EPA quality
manager conducted an independent assessment of the test laboratory in June 2005 and found that the test
laboratory was equipped and operated as specified in the test/QA plan.

The ETS QA officer and the APCT Center's QA staff have reviewed the results of this test and have
found that the results meet the overall data quality objectives as stated in the test/QA plan. It should be
noted that, because of the highly efficient nature of the filter medium being tested, the impactor substrate
weighings for these results were below the reproducibility of the balance. The relative percent error in the
post-filter weighing measurements cannot be computed because most of the values were near zero. As a
result of this occurrence, the tests do not meet the data quality objectives (DQOs) stated in the test/QA
plan for mass gain associated with outlet concentrations. However, as stated in the test protocol, "for
highly efficient fabrics, the mass gains stated for these quality objectives may not be achieved in the
specified test duration. For these tests it is acceptable for the indicated DQO not to be met."

Data on calibration certificates for the flow meters, flow transducers, weights, low- and high-resolution
balances, thermometer, and humidity logger are maintained at ETS in a separate data package.

Deviations from the test plan include organizational personnel changes.

The ETS QA officer and the APCT Center's QA staff have also reviewed the results of the control tests,
which are summarized in Section 2.3, Table 1. The dust characterization control test met the appropriate
requirements of the test/QA plan and verification protocol. The reference fabric tests met maximum AP
and weight gain requirements established for reference fabric performance in the GVP, indicating the
measurement system is operating in control.

4.2    Results

Table 2 summarizes the mean outlet particle concentration measurements for the verification test periods.
Measurements were conducted during the 6-hour performance test period. The performance test period
followed a 10,000-cycle conditioning period and a 30-cycle recovery period.

Table 2 summarizes the three verification tests that were performed under standard verification test
conditions. The average residual AP across each filter sample at the nominal 120 m/h (6.6 fpm) filtration
velocity [for a flow rate of 5.8 m3/h (3.4 cfm)] is also shown in Table 2. This AP ranged from 2.94 to 3.30
cm w.g. (1.16 to  1.30 in. w.g.) for the three filter samples tested. The residual AP increase ranged from
0.15 to 0.18 cm w.g. (0.06 to 0.07 in. w.g.) for the samples tested. All three standard condition
verification runs were used to compute the averages given in Table 2. The PM2 5 outlet particle
concentration average for the three runs is <0.0000167 g/dscm. The total PM concentration average for
the three runs is <0.0000167 g/dscm.

-------
Environmental Technology Verification Report
Donaldson Company, Inc. Tetratex 6262
         Table 2. Summary of Verification Results for Donaldson Company, Inc.'s
                               Tetratex 6262 Filtration Media
Test Run Number
PM2 .5 (g/dscm)b
Total PM (g/dscm)
Average residual A P (cm w.g.)
Initial residual A P (cm w.g.)
Residual A P increase (cm w.g.)
Mass gain of sample filter (g)
Average filtration cycle time (s)
Number of cleaning cycles
5V1-R1
<0. 0000167°
<0.0000167C
2.94
2.86
0.15
0.18
191
112
5V1-R2
<0. 0000167
<0.0000167
3.17
3.07
0.18
0.18
176
122
5V1-R3
<0.0000167
<0.0000167
3.30
3.22
0.16
0.16
169
127
Average3
<0.0000167
<0.0000167
3.14
3.05
0.16
0.17
179
120
a All three verification runs were used to compute averages.
b One or more of the impactor substrate weight changes for these results was near the reproducibility
  limit of the balance.
c The measured value was determined to be below the detection limit of 0.0000167 grams per cubic
  meter. The detection limit is for a six-hour test and based on VDI 3926.

4.3    Limitations and Applications

This verification report addresses two aspects of BFP performance: outlet particle concentration and AP.
Users may wish to consider other performance parameters, such as service life and cost, when selecting a
baghouse filtration fabric for their application.

In accordance with the GVP, the verification statement, which summarizes this test report, is applicable to
BFPs manufactured between the signature date of the verification statement and three years thereafter.
                                             10

-------
Environmental Technology Verification Report                Donaldson Company, Inc. Tetratex 6262
5.0     References

1.      RTI International. 2001. Generic Verification Protocol for Baghouse Filtration Products, RTI
        International, Research Triangle Park, NC, February. Available at
        http://www.epa.gov/etv/pubs/05_vp_bfp.pdf.

2.      ETS Incorporated and RTI International. 2006. Test/QA Plan for the Verification Testing of
        Baghouse Filtration Products (Revision 2), ETS Incorporated, Roanoke, VA, and RTI
        International, Research Triangle Park, NC, February. Available at