Office of Solid Waste and EPA-542-R-11-008
Emergency Response November 2011
(5102G) www.epa.gov/tio
www.clu-in.org/optimization
Remediation System Evaluation (RSE)
Tutu Wellfield Superfund Site
St. Thomas, U.S. Virgin Islands
-------
REMEDIATION SYSTEM EVALUATION
TUTU WELLFIELD SUPERFUND SITE
ST. THOMAS, U.S. VIRGIN ISLANDS
Report of the Remediation System Evaluation
Site Visit Conducted at the Tutu Wellfield Superfund Site on
February 8, 2011
Final Report
September 15, 2011
-------
NOTICE
Work described herein was performed by Tetra Tech GEO for the United States Environmental
Protection Agency (USEPA). Work conducted by Tetra Tech GEO, including preparation of this
report, was performed under Work Assignment #1-58 of USEPA contract EP-W-07-078 with
Tetra Tech EM, Inc., Chicago, Illinois. Mention of trade names or commercial products does not
constitute endorsement or recommendation for use.
-------
EXECUTIVE SUMMARY
A Remediation System Evaluation (RSE) involves a team of expert hydrogeologists and
engineers, independent of the site, conducting a third-party evaluation of the operating remedy. It
is a broad evaluation that considers the goals of the remedy, site conceptual model, available site
data, performance considerations, protectiveness, cost-effectiveness, closure strategy, and
sustainability. The evaluation includes reviewing site documents, potentially visiting the site for
one day, and compiling a report that includes recommendations in the following categories:
Protectiveness
Cost-effectiveness
Technical improvement
Site closure
Green Remediation
The recommendations are intended to help the site team identify opportunities for improvements.
In many cases, further analysis of a recommendation, beyond that provided in this report, may be
needed prior to implementation of the recommendation. Note that the recommendations are
based on an independent evaluation, and represent the opinions of the evaluation team. These
recommendations do not constitute requirements for future action, but rather are provided for
consideration by the United States Environmental Protection Agency (USEPA) Region and other
site stakeholders.
The Tutu Wellfield Superfund Site is a 1.5 square mile site located on the eastern end of St.
Thomas, U.S. Virgin Islands (USVI) within the upper Turpentine Run surface drainage basin in
the Anna's Retreat area. It is bounded by steep slopes and surrounding hills and lies slightly east
of the city of Charlotte Amalie. There are two comingled groundwater contamination plumes at
the site. The higher concentration, northern and upgradient plume has a source near the
Curriculum Center. The southern and downgradient plume has a source near the O'Henry Dry
Cleaners. Chemicals of concern (COC) in groundwater are specific chlorinated volatile organic
compounds (CVOCs). The USEPA identified several parties as potentially responsible for
contributing to the contamination plumes. The largest contributor was a source at the Curriculum
Center (former LAGA Building). This building was owned and operated by LAGA Textile
Company, a clothing manufacturing plant, from 1969 to 1979 when it changed hands to Panex
Co. until 1982. Extensive use of tetrachloroethylene (PCE) occurred at the plant via an industrial
size dry cleaning process that utilized the PCE as the dry cleaning solvent. Since 1982, the
building has been used as a library, warehouse, and school offices.
The groundwater remedy consists of two groundwater treatment facilities (GWTF). GWTF #1
includes groundwater extraction and treatment by air stripping near the Curriculum Center source
and previously also included soil vapor extraction (SVE). GWTF #2 includes groundwater
extraction and air stripping at the downgradient end of the Curriculum Center plume just
upgradient of the O'Henry plume. This RSE focuses on these systems and associated monitoring
program.
11
-------
In general, the RSE team found that the active remedy components are operated by capable and
organized operators. The observations and recommendations contained in this report are not
intended to imply a deficiency in the work of either the system designers or operators, but are
offered as constructive suggestions in the best interest of the USEPA and the public. These
recommendations have the benefit of being formulated based on operational data unavailable to
the original designers. Furthermore, it is likely that site conditions and general knowledge of
groundwater remediation have changed over time.
Recommendations are provided in effectiveness, cost reduction, technical improvement, site
closure, and sustainability.
Recommendations for improving system effectiveness are as follows:
Hydraulic Containment. Consider a new containment system including a line of wells
perpendicular to the flow direction screened through the shallow and deep zones near
RD-13 (300 ft downgradient) as the interpreted capture zone associated with GWTF #1 is
small relative to the size of the high-concentration portion of the plume. In addition, it is
recommended that two monitoring wells be installed east of the depicted plume where
data to define plume extents are lacking.
No Additional Downgradient Active Remediation: CVOC concentrations at down-
gradient wells have decreased over time and the plume size has decreased. The site team
has analyzed for natural attenuation parameters to help determine the biological portion
of the plume reduction and put controls in place to protect potential receptors in this area.
Improved containment at GWTF #1 may increase the rate of concentration decreases.
Vapor Intrusion Resampling. Vapor intrusion was detected in the Curriculum Center
during a December 2007 sub-surface and indoor air sampling event. Sampling has not
been conducted since the 2007 event and would be worthwhile to determine if conditions
have improved or degraded. If indoor air levels are found above standards, a mitigation
system or other controls should be considered.
Sampling Parameters. methyl tertiary butyl ether (MTBE) should be added to the
sampling parameters for the next annual event. If MTBE is found at levels of concern in
monitoring wells, further analysis will be needed to determine additional investigation
and remediation approaches.
Recommendations for cost reduction include the following:
Improve Contracting Efficiency.
o Electricity costs should not be part of the fixed-fee payment to reduce markup
and factor of safety costs. (This recommendation is made to potentially benefit
the USVI Department of Planning and Natural Resources [DPNR]/Division of
Environmental Protection [DEP].)
o Having both COM Federal Programs Corporation (CDM) and Arrowhead
Contracting, Inc. (Arrowhead) provide project management should not be
necessary. Eliminating or substantially reducing the project management from
one of these parties should result in savings of approximately $30,000 per year.
in
-------
Consider Shut Down of GWTF #2:
o Consider a temporary shutdown of GWTF#2 to evaluate if it is providing
meaningful remediation prior to GWTF #1 modifications. CVOC concentrations
at MW-12D and RD-7 could be monitored to determine if the decreasing trends
continue with GWTF #2 pumping suspended.
o With effective capture at GWTF #1, the GWTF #2 influent will continue to
decline. If not already terminated, GWTF #2 operation should be terminated as
soon as GWTF #1 improvements are completed and hydraulic containment is
confirmed by reduced downgradient concentrations (based on sampling at MW-
12D and RD-7).
Operation and Monitoring.
o Reduce number of site visits from daily to once or twice weekly. (This
recommendation is made to potentially benefit the USVI DPNR/DEP.)
o Well gauging frequency should be decreased from monthly to quarterly.
Quarterly gauging will provide sufficient information for system operations.
Eliminate GWTF Emissions Sampling. Eliminate monthly air emission sampling at
GWTF #1. Like GWTF #2, air emission mass calculations at GWTF #1 should be based
on the assumption that 100% of VOCs in water are removed by the air stripper.
Recommendations for technical improvement include the following:
Remove the excess pipe between the air stripper discharge and stack to reduce friction
loss and required blower head. This should allow for a smaller (about 10 horsepower
[HP]) unit to be used to replace the existing 15 HP unit even with the suggested increased
flow associated with the new containment system. This is a technical improvement as
well as a cost reduction factor due to reduced electricity usage.
Consider installation of a variable frequency drive (VFD) which could be installed for the
existing blower instead of installing a new smaller blower for a similar cost and cost
reduction.
If operation is expected to continue for many years, following optimization of the
extraction system (assume to be complete by 2013), consider replacing the tray unit air
stripper with a packed tower for additional yearly savings in electricity usage.
Prior to making any changes, the air stripper design for the proposed extraction system
should be evaluated based on proposed influent flow rates and concentrations to confirm
blower requirements.
IV
-------
Recommendations for gaining site closure include the following:
Alternative technologies are not appropriate for further consideration at this time.
Focusing on improving containment at GWTF #1 is the key to reducing downgradient
impacts and that GWTF #2 may not need to continue operating for much longer. A
limited in-situ technology ERD action or in-situ chemical oxidation could be considered
in the O'Henry's area if concentrations in this area persist several years after the
improvements at GWTF #1 are made.
Recommendations for improved green remediation include the following:
Treated water meeting drinking water standards is currently discharged to the storm
sewer even though water is a precious commodity on St. Thomas. The water could be
used for irrigation or commercial (car washing or laundromat) purposes nearby. Further
efforts should be made to have the discharged water accepted for another use. This could
possibly help eliminate illegal pumping of private wells for irrigation and commercial
purposes.
Table 6-1 summarizes the recommendations, including estimated costs and/or savings associated
with the recommendations and is presented in Section 6.0 of this report.
-------
PREFACE
This report was prepared as part of a project conducted by the USEPA Office of Superfund
Remediation and Technology Innovation (OSRTI). The objective of this project is to conduct
independent, expert reviews of soil and groundwater remedies with public funding with the
purpose of optimizing the remedy for protectiveness, cost-effectiveness, and green remediation.
The project contacts are as follows:
Organization
Key Contact
Contact Information
U.S. EPA Office of Superfund
Remediation and Technology
Innovation
(OSRTI)
Kathy Yager
U.S. EPA Technology Innovation and
Field Services Division
11 Technology Drive (ECA/OEME)
North Chelmsford, MA 01863
phone: 617-918-8362
vager.kathleen@epa.gov
Tetra Tech EM, Inc.
(Contractor to USEPA)
Jody
Edwards, PG
Tetra Tech EM, Inc.
1881 Campus Commons Drive, Suite 200
Reston,VA20191
phone: 802-288-9485
jody.edwards@tetratech.com
Tetra Tech GEO
(Contractor to Tetra Tech EM, Inc.)
Doug Sutton,
P.E., PhD.
Tetra Tech GEO
2 Paragon Way
Freehold, NJ 07728
phone:732-409-0344
doug. sutton@tetratech. com
VI
-------
TABLE OF CONTENTS
NOTICE i
EXECUTIVE SUMMARY ii
PREFACE vi
TABLE OF CONTENTS vii
1.0 INTRODUCTION 1
1.1 PURPOSE 1
1.2 TEAM COMPOSITION 2
1.3 DOCUMENTS REVIEWED 2
1.4 PERSONS CONTACTED 3
1.5 BASIC SITE INFORMATION AND SCOPE OF REVIEW 4
1.5.1 LOCATION 4
1.5.2 SITE HISTORY, POTENTIAL SOURCES, AND RSE SCOPE 4
1.5.3 GEOLOGIC/HYDROGEOLOGIC SETTING 6
1.5.4 POTENTIAL RECEPTORS 7
1.5.5 DESCRIPTION OF GROUND WATER PLUME 7
2.0 SYSTEM DESCRIPTION 9
2.1 EXTRACTION SYSTEMS 9
2.2 TREATMENT SYSTEMS 9
2.3 MONITORING PROGRAM 10
3.0 SYSTEM OBJECTIVES, PERFORMANCE, AND CLOSURE CRITERIA 11
3.1 CURRENT SYSTEM OBJECTIVES AND CLOSURE CRITERIA 11
3.2 TREATED WATER DISCHARGE STANDARDS 12
3.3 VAPOR DISCHARGE STANDARDS 13
4.0 FINDINGS 14
4.1 GENERAL FINDINGS 14
4.2 SUBSURFACE PERFORMANCE AND RESPONSE 14
4.2.1 PLUME CAPTURE 14
4.2.2 GROUND WATER CONTAMINANT CONCENTRATIONS 20
4.2.3 INSTITUTIONAL CONTROLS TO PREVENT USE OF IMPACTED
GROUNDWATER 20
4.2.4 SOIL VAPOR EXTRACTION/VAPOR INTRUSION 20
4.3 COMPONENT PERFORMANCE 21
4.3.1 GROUNDWATER EXTRACTION SYSTEM 21
4.3.2 TREATMENT SYSTEM FOR EXTRACTED WATER 21
4.3.3 VOCs REMOVED BY SYSTEMS 22
4.4 COMPONENTS OR PROCESSES THAT ACCOUNT FOR MAJORITY OF
ANNUAL COSTS 22
vii
-------
4.4.1 PROJECT MANAGEMENT 22
4.4.2 ARROWHEAD FIXED FEE 23
4.4.3 MATERIALS 23
4.4.4 UTILITIES 23
4.4.5 SAMPLING 23
4.5 APPROXIMATE ENVIRONMENTAL FOOTPRINTS ASSOCIATED WITH THE REMEDY 23
4.6 RECURRING PROBLEMS OR ISSUES 24
4.7 REGULATORY COMPLIANCE 25
4.8 SAFETY RECORD 25
5.0 EFFECTIVENESS OF THE SYSTEMS TO PROTECT HUMAN HEALTH AND
THE ENVIRONMENT 26
5.1 GROUNDWATER 26
5.2 SURF ACE WATER 26
5.3 AIR 26
5.4 SOIL 26
5.5 WETLANDS AND SEDIMENTS 26
6.0 RECOMMENDATIONS 27
6.1 RECOMMENDATIONS TO IMPROVE EFFECTIVENESS 27
6.1.1 HYDRAULIC CONTAINMENT 27
6.1.2 No ADDITIONAL DOWNGRADIENT ACTIVE REMEDIATION 28
6.1.3 VAPOR INTRUSION RESAMPLING 28
6.1.4 SAMPLING PARAMETERS 28
6.2 RECOMMENDATIONS TO REDUCE COSTS 29
6.2.1 IMPROVE CONTRACTING EFFICIENCY 29
6.2.2 CONSIDER SHUT DOWN OF GWTF #2 29
6.2.3 OPERATION AND MONITORING 30
6.2.4 ELIMINATE GWTF EMISSIONS SAMPLING 30
6.3 RECOMMENDATIONS FOR TECHNICAL IMPROVEMENT 30
6.4 CONSIDERATIONS FOR GAINING SITE CLOSE OUT 31
6.5 RECOMMENDATIONS FOR IMPROVED GREEN REMEDIATION 31
6.5.1 WATER DISCHARGE 31
6.5.2 ALTERNATIVE ENERGY SOURCES 31
Vlll
-------
Tables
Table 1-1. Tetra Tech GEORSE Team 2
Table 1-2. Participants of Site Visit 3
Table 3-1. Chemicals in Groundwater Above Remedial Action Levels (RALs) 12
Table 3-2. TPDES Permit Limits 12
Table 3-3. Air Pollution Control Permit Limits 13
Table 4-1. Total CVOC Remediation from 2004 to 2010 16
Table 4-2. Calculation of Flow Required for Capture at Curriculum Center 18
Table 4-3. Analytical Results of Vapor Intrusion Study 21
Table 4-4. Annual Operations and Maintenance Costs 22
Table 4-5. Summary of GWTF #1 Air Emissions 24
Table 4-6. Summary of GWTF #2 Air Emissions 24
Table 6-1. Recommendations Cost Summary Table 33
Table 6-2. Green Remediation Summary Table for Recommendations 34
Appendices
Appendix A Selected Figures from Previous Site Reports
IX
-------
ACRONYMS AND ABBREVIATIONS
AOC
Arrowhead
COM
CERCLA
CLP
COC
CVOC
DCE
DEP
DNAPL
DPNR
EPA
ERD
FS
ft
gpm
GWTF
HOPE
HP
1C
in
"H2O
1C
KWhr
Ibs
MCL
mg/L
MNA
msl
MTBE
NPL
OSWER
OSRTI
%
P&T
PCE
PRP
RA
RAL
RAO
RCRA
RD
Administrative Order of Consent
Arrowhead Contracting, Inc.
CDM Federal Programs Corporation
Comprehensive Environmental Response, Compensation, and
Liability Act
Contract Laboratory Program
Constituent of Concern
Chlorinated Volatile Organic Compound
Di chl oroethy 1 ene
Division of Environmental Protection
Dense Non-Aqueous Phase Liquid
Department of Planning and Natural Resources
Environmental Protection Agency
Enhanced Reductive Dechlorination
Feasibility Study
feet
gallons per minute
Groundwater Treatment Facility
high density polyethylene
horsepower
Institutional Control
inches
inches of water
Institutional Control
kilowatt hour
pounds
Maximum Contaminant Level
micrograms per liter
milligrams per liter
Monitored Natural Attenuation
mean sea level
Methyl Tertiary Butyl Ether
National Priorities List
Office of Solid Waste and Environmental Response
Office of Superfund Remediation and Technology Innovation
percent
Pump and Treat
Tetrachl oroethy 1 ene
Potentially Responsible Party
Remedial Action
Remedial Action Levels
Remedial Action Objective
Resource, Conservation and Recovery Act
Remedial Design
-------
REAC
RI
ROD
RSE
scfm
SVE
TCE
TOC
TSS
TPDES
TSG
UAO
USEPA
UST
USVI
VC
VFD
VOC
WAPA
Response, Engineering, and Analytical Contract
Remedial Investigation
Record of Decision
Remediation System Evaluation
standard cubic feet per minute
Soil Vapor Extraction
Tri chl oroethy 1 ene
Total Organic Carbon
Total Suspended Solids
Territorial Pollutant Discharge Elimination System
The Solutions Group Water Resources
Unilateral Administrative Order
United States Environmental Protection Agency
Underground Storage Tank
United States Virgin Islands
Vinyl Chloride
Variable Frequency Drive
Volatile Organic Compound
USVI Water and Power Authority
XI
-------
1.0 INTRODUCTION
1.1 PURPOSE
During fiscal years 2000 and 2001 independent reviews called Remediation System Evaluations
(RSEs) were conducted at 20 operating Fund-lead pump-and-treat (P&T) sites (i.e., those sites
with P&T systems funded and managed by Superfund and the States). Due to the opportunities
for system optimization that arose from those RSEs, United States Environmental Protection
Agency (USEPA) Office of Superfund Remediation and Technology Innovation (OSRTI) has
incorporated RSEs into a larger post-construction complete strategy for Fund-lead remedies as
documented in Office of Solid Waste and Environmental Response (OSWER) Directive No.
9283.1-25, Action Plan for Ground Water Remedy Optimization, and has also started conducting
RSEs at some Potential Responsible Party (PRP)-lead sites. A strong interest in green practices
has also developed in the private and public sectors. Consistent with this interest, OSRTI has
developed a Green Remediation Primer (http://cluin.org/greenremediation/) and, as a pilot effort
now considers green remediation during independent evaluations.
The RSE process involves a team of expert hydrogeologists and engineers that are independent of
the site, conducting a third-party evaluation of the operating remedy. It is a broad evaluation that
considers the goals of the remedy, site conceptual model, available site data, performance
considerations, protectiveness, cost-effectiveness, closure strategy, and green remediation. The
evaluation includes reviewing site documents, potentially visiting the site for one day, and
compiling a report that includes recommendations in the following categories:
Protectiveness
Cost-effectiveness
Technical improvement
Site closure
Green remediation
The recommendations are intended to help the site team identify opportunities for improvements.
In many cases, further analysis of a recommendation, beyond that provided in this report, may be
needed prior to implementation of the recommendation. Note that the recommendations are
based on an independent evaluation, and represent the opinions of the evaluation team. These
recommendations do not constitute requirements for future action, but rather are provided for
consideration by the Region and other site stakeholders.
The Tutu Wellfield Superfund Site was selected by the USEPA OSRTI based on a nomination
from USEPA Region 2. The site is located on the eastern end of St. Thomas, U.S. Virgin Islands
(USVI) within the upper Turpentine Run surface drainage basin in the Anna's Retreat area. It is
bounded by steep slopes and surrounding hills and lies slightly east of the city of Charlotte
Amalie. There are two comingled groundwater contamination plumes at the site (Appendix A).
The higher concentration, northern and upgradient plume has a source near the Curriculum
Center. The southern and downgradient plume has a source near the O'Henry Dry Cleaners.
Chemicals of concern (COC) in groundwater are specific chlorinated volatile organic compounds
(CVOCs):
-------
Tetrachloroethylene (PCE)
Trichloroethylene (TCE)
cis-l,2-Dichloroethylene (cis-l,2-DCE)
trans- 1,2-Dichloroethylene (trans-1,2-DCE)
Vinyl chloride (VC)
The groundwater remedy consists of two groundwater treatment facilities (GWTF). GWTF #1
includes groundwater extraction and treatment by air stripping near the Curriculum Center source
and previously (2004 to 2006) also included soil vapor extraction (SVE). GWTF #2 includes
groundwater extraction and air stripping at the downgradient end of the Curriculum Center plume
just upgradient of the O'Henry plume (Southern Plume) (see Appendix A). The RSE provides an
opportunity for an independent third-party review of these remediation efforts.
1.2 TEAM COMPOSITION
The RSE team consisted of the following individuals:
Table 1-1. Tetra Tech GEO RSE Team
Name
Peter Rich
Greg Council
Kirby Biggs
Affiliation
Tetra Tech GEO
Tetra Tech GEO
USEPA/HQ TIFSD
Telephone
410-990-4607
770-619-9950
703-823-3081
Email
peter.rich@tetratech.com
greg.council@tetratech.com
biggs .kirby@epa.gov
1.3 DOCUMENTS REVIEWED
The following documents were reviewed. The reader is directed to these documents for
additional site information that is not provided in this report.
April 2010 Annual Remedial Action Progress Report (CDM Federal Programs
Corporation) - April 2010
Five-Year Review Report (USEPA Region 2) - April 2009
Work Assignment 0-291 - Air Sampling Trip Report (Lockheed Martin Technology
Services) - March 2008
Final Operations and Maintenance Manual Groundwater Treatment Facilities #1 and #2
Volume I of II (CDM Federal Programs Corporation) - June 2004
Phase I Enhanced Anaerobic Bioremediation (EAB) Pilot Study Technical Memorandum
(CDM Federal Programs Corporation) - December 2004
Groundwater Modeling Report, Tutu Wellfield Site, Site-Wide Groundwater Remedial
Design (CDM Federal Programs Corporation) - March 2002
Record of Decision (USEPA Region 2) - July 1996
-------
Draft Final Phase II Remedial Investigation (Geraghty & Miller, Inc.) - January 1995
Final Pre-Design Report: Tutu Wells (Groundwater), Tutu Wells (Soil) Remedial Design
(COM Federal Programs Corporations) - unknown date
1.4 PERSONS CONTACTED
The following individuals associated with the Tutu Wellfield Superfund Site were present for the
visit:
Table 1-2. Participants of Site Visit
Name
Greg Council
Peter Rich
Caroline Kwan
Kirby Biggs
Demetrios
Klerides
Chris Guenther
Bob Petersen
Maritza Araud
Diana Joshua
Affiliation
Tetra Tech GEO
Tetra Tech GEO
USEPA - R2
USEPA/HQ
TIFSD
COM
TSG
TSG
DPNR/DEP
DPNR/DEP
Telephone
770-619-9950
410-990-4607
212-637-4275
703-823-3081
212-785-9123
321-394-6661
340-513-0447
340-773-1082 ext.9023
340-774-3320 ext. 5277
Email
greg.coucil@tetratech.com
peter. rich@tetratech. com
kwan.caroline@epa.gov
biggs.kirby@epa.gov
kleride sd@cdm . com
cguenther@tsgwater.com
bpetersen@tsgwater . com
maraudpza@hotmail .com
diana.j oshua@dpnr.gov
Note: DPNR/DEP = USVI Department of Planning and Natural Resources, Division of Environmental
Protection
COM Federal Programs Corporation (COM) is the contractor to USEPA Region 2; the COM
project manager and support staff are based in New York. CDM subcontracts Arrowhead
Contracting, Inc. (Arrowhead), based in Kansas City, to provide full service operation and
sampling at the site. Arrowhead was the original installer of the treatment systems and they
continue to provide engineering support and groundwater sampling services. Arrowhead
subcontracts The Solutions Group Water Resources (TSG) to provide plant operations, process
sampling services and other local support.
-------
1.5 BASIC SITE INFORMATION AND SCOPE OF REVIEW
1.5.1 LOCATION
The Tutu Wellfield Superfund Site is a 1.5 square mile site located on the eastern end of St.
Thomas, USVI within the upper Turpentine Run surface drainage basin in the Anna's Retreat
area. The Turpentine Run surface drainage basin trends north-south and is ultimately bounded by
steep slopes. Locally, the site is surrounded by densely developed commercial and residential
areas including a school to the north of the main CVOC source. The nearest city is Charlotte
Amalie which lies west of the site.
1.5.2 SITE HISTORY, POTENTIAL SOURCES, AND RSE SCOPE
The USEPA identified the following parties as potentially responsible for contributing to the
contamination plumes at the Tutu Wellfield Superfund Site: Tutu Texaco Service Station, Esso
Tutu Service Station, Ramsay Motor Company, Antilles Auto Parts, Virgin Island Housing
Authority, Curriculum Center, O'Henry Dry Cleaners, Tillet Gardens and Western Auto. The
largest contributor to the groundwater plumes was a source at the Curriculum Center (former
LAGA Building). This building was owned and operated by LAGA Textile Company (LAGA), a
clothing manufacturing plant, from 1969 to 1979 when it changed hands to Panex Co. until 1982.
Extensive use of PCE occurred at the plant via an industrial size dry cleaning process that utilized
the PCE as the dry cleaning solvent. Since 1982, the building has been used as a library,
warehouse, and school offices. Groundwater contamination from this location is thought to have
occurred from poor waste storage and disposal. Evidence suggests that volatile organic
compound (VOC)-contaminated wastes were dumped into a sink at the rear of the building and
wastes were discharged to the subsurface through an unidentified pipe to a suspected unlined
sump/septic system. In addition, badly corroded and perforated 55-gallon drums were found
abandoned at the site. Investigation of the site was initiated in July 1987. The 1996 Record of
Decision (ROD) and the Five-Year Review (April 2009) provides the following information:
July 1987: Investigation at the site begins pursuant to a complaint from Mr. Tillett,
owner of Tillett Gardens, of an odor emanating from his groundwater supply well. Six
supply wells are sampled in the Tutu area.
July - September 1987: Groundwater sampling and screening investigation is expanded
to include 24 supply wells. Based on groundwater sampling results, the USVI
Department of Planning and Natural Resources (DPNR) closes 13 commercial and five
private wells in the Tutu area.
January 1988: USEPA initiates a limited Comprehensive Environment Response,
Compensation, and Liability Act (CERCLA) removal action that includes the
decontamination and cleaning of five residential cisterns contaminated by hazardous
substances, modification of plumbing, delivery of water by tank truck as a temporary
alternate water supply, and implementation of a well-water monitoring program.
-------
1988 - 1990: USEPA sends Information Request letters under Section 104 of CERCLA
and Section 3007 of the Resource, Conservation and Recovery Act (RCRA) to many
businesses regarding operations and waste disposal at these businesses. Based on the
findings, Unilateral Administrative Orders (UAOs) are issued to Texaco, Esso, and
O'Henry Dry Cleaners to implement a well-water monitoring program, provide potable
water to affected residents, and coordinate design plans to connect affected residents to
public water supply.
February 1992: A Hazard Ranking System package is prepared and the site is proposed
for addition to the National Priorities List (NPL). USEPA issues Administrative Order of
Consent (AOC) to Texaco and Esso to implement a Remedial Investigation (RI) and
Feasibility Study (FS).
1992 - 1995: Various RI and FS activities are conducted.
August 1994: Western Auto removes underground storage tank (UST) and paves the
area with a concrete cap.
March 1995: USEPA issues Consent Orderto O'Henry Dry Cleaners for soil cleanup.
Pursuant to the Order, O'Henry Dry Cleaners performs soil removal.
September 1995: Tutu Wellfield Superfund Site is added to the NPL.
August 1996: A ROD is signed.
1998: Construction completed for the Texaco Service Station groundwater and soil
treatment system and Vitelco groundwater treatment system. Texaco Service Station
system is placed in operation.
May 1998: USEPA issues UAOs to Texaco, Esso, and Western Auto/Four Winds Plaza
for Remedial Designs (RDs) and Remedial Actions (RAs) to address site contamination.
August 1998 - November 1999: Pre-design investigation is performed for Curriculum
Center soils and site-wide groundwater.
1999: Esso groundwater and soil treatment system construction is completed and system
is placed in operation.
January - February 1999: Pre-design investigation is performed at Western Auto/Four
Winds Plaza.
May 1999: USEPA issues UAO to O'Henry Dry Cleaners for RDs and RAs to address
site contamination.
November 1999: O'Henry Dry Cleaners performs pre-design soil delineation
investigation.
January 2000: USEPA approves No Further Action recommendation regarding ROD-
specified soil contamination for Western Auto/Four Winds Plaza.
-------
July 2001: USEPA approves No Further Action recommendation for O'Henry Dry
Cleaners.
September 2001: USEPA completes design for Curriculum Center groundwater
treatment and SVE system, and side-wide groundwater treatment.
2001 - 2002: Contaminated soils at Esso Service Station are excavated and treated in
bio-cells. Esso "Hot-Spot" remediation system is constructed.
2002 - 2005: Operation of the Esso Service Station "Hot-Spot" remediation system
occurs.
July 2003: Texaco Service Station groundwater and SVE systems are shut down after a
period of pulsed extraction.
July 2003 - present: Monitored Natural Attenuation (MNA) activities are conducted for
Texaco Service Station.
March 2004: Site construction is completed for Curriculum Center soils and site-wide
groundwater. System is placed in operation.
March 2004 - March 2006: Operation, maintenance, and monitoring activities for
Curriculum Center SVE and off-gas systems.
March 2004 - present: Operation, maintenance, and monitoring activities performed for
site-wide groundwater.
2005 - present: MNA activities are conducted for Esso Service Station.
December 2006: Removal and replacement of three USTs and associated fuel lines are
performed at the Texaco Service Station.
January 2007: Enhanced bioremediation application is performed at the Texaco Service
Station.
1.5.3 GEOLOGIC/HYDROGEOLOGIC SETTING
The geologic and hydrogeologic setting at the Tutu Wellfield Superfund Site is complex and
includes overburden (surficial silty, clayey fill and weathered bedrock) and volcanic bedrock. In
the March 2002 Groundwater Modeling Report, the aquifer system is divided into six layers
which are described as follows:
Layer 6 (Overburden) represents low-permeability, silt/clay overburden, excluding localized
areas where it is known to be absent (e.g., bedrock outcrop, stream beds). The ground surface
corresponds to the top of Layer 6. The thickness of Layer 6 was defined based upon existing
boring logs and overburden thickness iso-contour maps and generally varies from 5 to 40 feet
in thickness across the valley.
-------
Layers 5 through 2 represent bedrock. Layers 5 (Upper Productive Zone), 4 (Lower
Productive Zone), and 3 (Lower Aquifer) correspond to the productive aquifer zones, where
groundwater flow predominantly occurs at the site along controlling fracture sets (i.e.,
"lineaments"), represented in the model as areas of higher hydraulic conductivity. Most of the
extraction/supply wells and monitoring wells constructed at the site are screened within
Layers 4 and/or 5. Layer 2 (Non-Productive Unit) corresponds to a non-productive portion of
the aquifer. The thicknesses corresponding to Layers 4 and 5 (20-30 feet) each and Layer 3
(60-75 feet) were generally defined based upon the results of pump tests, drilling/coring logs,
and down-hole geophysics. Layer 2 was assigned a constant thickness of 290 feet.
Layer 1 represents the deep bedrock. The base of the model (impervious boundary condition)
corresponds to the bottom of Layer 1. The bottom of this layer corresponds to the depth of
freshwater based upon the Ghyben-Herberg principle, and is beyond the influence of pumping
at the Tutu Wellfield Superfund Site. This layer varies in thickness from 1,068 to 8,375 feet.
The weathered bedrock at the site is red-brown or greenish grey andesitic breccia with a clay
matrix. The moderately weathered bedrock is underlain by lithified pyroclastic flow deposits
consisting of green andesitic breccias, calcite veins, and iron staining along fractures.
1.5.4 POTENTIAL RECEPTORS
Based on discussions during the RSE site visit, the primary potential receptors are:
Groundwater users: There are residential and commercial properties with groundwater
wells within the contamination area. The DPNR issued Orders to close down those
supply wells and the residential properties have been receiving potable water (by truck
delivery). According to the terms of those Orders, authorization must be obtained from
the Virgin Islands Government prior to the use of these existing wells or the installation
of any new wells. However, it is suspected that sporadic illegal pumping of private wells
for irrigation and commercial purposes may be occurring at the Site.
Nearby residences/businesses: Nearby residences and businesses located above the
plume are potential receptors via vapor intrusion.
1.5.5 DESCRIPTION OF GROUNDWATER PLUME
There are two CVOC (including PCE and its degradation products) groundwater contamination
plumes associated with the Tutu Wellfield Superfund Site. Contaminants in the Northern Plume
(upgradient plume) migrate southwest from north of the Curriculum Center. This plume extends
vertically from 15 to 30 feet (ft) below ground surface (bgs) to approximately 80 ft bgs.
Contaminants in the Southern Plume (downgradient plume) migrate southeast from O'Henry Dry
Cleaners and along Turpentine Run. These two groundwater plumes are co-mingled. The
contaminants above federal maximum contaminant levels (MCLs) for these two plumes are
CVOCs. Maximum PCE concentrations from April 2010 (see Section 4.2.2) are 15,211
micrograms per liter ((ig/L) and 85 (ig/L near the Curriculum Center source and O'Henry's
source, respectively. (The PCE Remedial Action Level (RAL) is 5 (ig/L.)
-------
Two petroleum product plumes (including benzene, toluene, ethylbenzene and xylenes) also
existed on the site and near the Texaco and Esso Service Stations. These plumes appear to have
been confined to smaller areas than the CVOC plumes and have been addressed by remediation
efforts. The petroleum plumes appear to have had some impact on dechlorination of the CVOC
plume at select locations near the petroleum plume sources. It appears that testing for methyl
tertiary butyl ether (MTBE) has not been conducted. MTBE is a common gasoline additive that
frequently migrates further from a source than other petroleum related compounds.
-------
2.0 SYSTEM DESCRIPTION
The operating systems at the site include:
GWTF # 1: A groundwater extraction and treatment system to remediate the Northern
Plume near the source. This system was also equipped with SVE capabilities which are
no longer used.
GWTF #2: A groundwater extraction and air stripping system to remediate the
downgradient extent of the Northern Plume ("Northern Edge Plume").
These active remedy components are discussed in more detail below.
2.1 EXTRACTION SYSTEMS
Extraction systems currently include only groundwater extraction wells:
Groundwater Extraction - The groundwater extraction systems consist of five
groundwater extraction wells. Three of these extraction wells (RW-6, RW-7 and RW-9)
are connected to GWTF #1. RW-6 contains an electric submersible well pump with a 1A
horsepower (HP) motor and is pumped weekly with approximately 120 gallons removed
each week. RW-7, which formerly extracted groundwater and soil vapor, now only
extracts groundwater. This well contains an electric submersible well pump with a 1.5
HP motor and variable frequency drive. It operates continuously at approximately 18
gallons per minute (gpm) to maintain a head level of 148 ft above mean sea level (msl).
RW-9 contains an electric submersible well pump with a % HP motor. It operates during
system startup and during high rainfall events to supplement pumping from RW-7 to
maintain the design head level.
The remaining two extraction wells (RW-1 and RW-1S) are connected to GWTF #2.
RW-1 is equipped with an electric submersible well pump with a 1A HP motor and is only
operated periodically to prevent the pump from seizing. RW-1S contains an electric
submersible well pump with a 1.5 HP motor. It operates at a continuous pumping rate of
approximately 18 gpm to maintain a head level of 122 ft msl.
The groundwater extraction wells each have separate 1.5 inch (in) high density
polyethylene (HDPE) discharge lines to a manifold with a strainer, flow meter, check
valve and isolation valves. Groundwater is transported to each of the treatment facilities
via underground and above-ground piping. Electric power is run to the well pumps in
conduit.
2.2 TREATMENT SYSTEMS
GWTF #1: The separate 1.5-inch HDPE discharge lines are combined, and the blended
influent passes through a digital flow meter. An influent equalization tank is present but
-------
is bypassed except when RW-6 is pumped and the higher concentration water from RW-6
is mixed with the RW-7 water prior to treatment. The water is treated with anti-scale
(Caltrol 100) then put through two parallel 50 micron (|i) bag filters then another flow
meter prior to a six-tray Carbonair air stripper. The air stripper has a 15 HP regenerative
blower providing 360 standard cubic feet per minute (scfm) at approximately 60 inches
of water (" H2O). Air is discharged directly to the atmosphere; a formerly used vapor
treatment system is bypassed. Acid is added to the treated water to decrease the pH from
the natural value of pH 9 to below the discharge limit for the storm drain (pH 8.3).
GWTF #2: The separate 1.5-inch HDPE discharge lines are combined, and the blended
influent passes through a digital flow meter. The equalization tank is bypassed. The
water is treated with anti-scale (Caltrol 100) then put through two parallel 50(i bag filters
then another flow meter prior to a six tray Carbonair air stripper. The air stripper has a 5
HP regenerative blower providing approximately 180 scfm. Air is discharged directly to
the atmosphere. Acid is added to the treated water to decrease the pH from the natural
value of pH 9 to below the discharge limit for the storm drain (pH 8.3).
2.3 MONITORING PROGRAM
The monitoring program at the site consists of daily, weekly, monthly, semi-annual, and annual
sampling/monitoring events. These events include process sampling/monitoring, off-gas
sampling, groundwater sampling, groundwater level monitoring, system checks and air stripper
cleaning. The following is a schedule of sampling/monitoring events:
Daily system checks are conducted for flow rates, pressure, and pH readings for both
treatment facilities.
Weekly effluent water process samples are collected from both treatment facilities to
verify permit compliance. These samples are analyzed for total organic carbon (TOC)
and total suspended solids (TSS). System acid is also batched (diluted for injection into
the process water for pH adjustment) on a weekly basis.
Monthly influent and effluent water process samples are collected to verify permit
compliance. These samples are analyzed for VOCs. Off-gas samples are also collected
on a monthly basis from the discharge stack of GWTF #1 and analyzed for VOCs. Air
emissions are calculated monthly at GWTF #2 using the influent groundwater
concentrations and an assumed 100 percent (%) VOC removal. Other monthly activities
include groundwater level monitoring, bag filter change-outs and anti-scale batching.
Semi-annual activities consist of cleaning the air stripper trays using an acid wash.
Annual groundwater sampling is conducted at 30 groundwater monitoring wells and
samples are analyzed for VOCs. Samples from five of the groundwater monitoring wells
located in the Southern Plume (O'Henry's plume) area are additionally analyzed for
natural attenuation parameters including nitrate, sulfate, chloride, TOC and ethane/ethene
to determine the biological contribution to attenuation.
10
-------
3.0 SYSTEM OBJECTIVES, PERFORMANCE, AND CLOSURE
CRITERIA
3.1 CURRENT SYSTEM OBJECTIVES AND CLOSURE CRITERIA
The 1996 ROD identifies the following groundwater Remedial Action Objectives (RAOs):
Remove and/or control the sources of groundwater contamination.
Remove contamination in groundwater. Restore the aquifer to drinking water standards
(Remedial Action Levels [USEPA MCLs at the date of the ROD]included in Table 3-1)
except to the extent that such full groundwater restoration proves to be technically
impracticable due to the presence of Dense Non-Aqueous Phase Liquids (DNAPLs).
Control the migration of impacted groundwater.
Prevent human ingestion of groundwater exhibiting excess lifetime cancer risk greater
than 1 in 10,000 or a hazard index greater than 1.
Eliminate leaching of contaminants of concern from soils into groundwater at
concentrations which adversely impact groundwater quality and which might ultimately
have negative ecological effects.
11
-------
Table 3-1. Chemicals in Groundwater Above Remedial Action Levels (RALs)
Chemical of Concern
Vinyl chloride
1,2-Dichloroethene (total)
1 ,2-Dichlorethane
Trichloroethylene
Tetrachloroethylene
Benzene
Toluene
Ethylbenzene
Xylenes (total)
Aluminum
Antimony
Arsenic
Barium
Beryllium
Chromium
Copper
Iron
Lead
Manganese
Mercury
Nickel
Thallium
Chloride
Nitrate
RAL (ng/L)
2
100
5
5
5
5
1000
700
10000
50 to 200
5
50
2000
4
100
1,300
300
15
50
2
100
2
250,000
10,000,000
3.2 TREATED WATER DISCHARGE STANDARDS
The Tutu Wellfield Superfund Site is required to comply with the USVI DPNR Territorial
Pollutant Discharge Elimination System (TPDES) permit limits, listed in Table 3-2:
Table 3-2. TPDES Permit Limits
Constituent
CVOCs
TOC
TSS
pH
Permit Limit
99% removal or Non-Detect
< 20 mg/L
< 40 mg/L
7.0-8.3
Notes: mg/L = milligrams per liter
The site team reports that these standards are not exceeded with the exception of
occasional, brief pH excursions due to natural groundwater pH above 8.3.
12
-------
3.3 VAPOR DISCHARGE STANDARDS
The Tutu Wellfield Superfund Site is required to comply with the USVI Air Pollution Control
permit limits, listed in Table 3-3:
Table 3-3. Air Pollution Control Permit Limits
Constituent
PCE
TCE
cis-l,2-DCE
Vinyl chloride
Total CVOCs
Permit Limit (Ibs per day)
0.42
0.16
14.29
0.01
14.48
The systems are operated with emissions far below these standards. Total VOC emissions from
GWTF #1 and GWTF #2 combined are <0.05 Ibs per day total VOCs and vinyl chloride is a
minor (<5 % of total VOCs) constituent.
13
-------
4.0 FINDINGS
4.1 GENERAL FINDINGS
The RSE team observed that the active remedy components are operated by capable and
organized operators. The observations provided below are not intended to imply a deficiency in
the work of the system designers, system operators, or site managers but are offered as
constructive suggestions in the best interest of the USEPA and the public. These observations
have the benefit of being formulated based upon operational data unavailable to the original
designers. Furthermore, it is likely that site conditions and general knowledge of groundwater
remediation have changed over time.
4.2 SUBSURFACE PERFORMANCE AND RESPONSE
4.2.1 PLUME CAPTURE
Plume capture was evaluated for each of the two active groundwater extraction systems operated
by the site team. Plume capture was assessed by:
(a) Reviewing potentiometric surface maps generated from water-level measurements;
(b) Reviewing measured concentrations of CVOCs in groundwater wells downgradient of
extraction wells;
(c) Calculating the expected flow needed for capture using available estimates of aquifer
transmissivity, hydraulic gradient, and plume width; and,
(d) Reviewing the results of numerical groundwater modeling.
This approach to evaluating plume capture is consistent with USEPA guidelines documented in A
Systematic Approach for Evaluation of Capture Zones at Pump and Treat Systems (EPA 600/R-
08/003). Under these guidelines, adequate capture is indicated if the weight of evidence obtained
from evaluations such as those listed above suggests that the plume (or target capture zone) is
being captured under prevailing conditions.
4.2.1.1 Curriculum Center Area (GWTF #1) Plume Capture Evaluation
It is assumed in this discussion that a primary goal of the GWTF #1 extraction system is to
capture the CVOC plume where the total CVOC concentration is greater than 100 (ig/L. This is
consistent with the April 2009 Five-Year Review Report which noted that natural attenuation was
appropriate for total CVOC concentrations below 100 (ig/L.
14
-------
Potentiometric Surface Evaluation
The first figure in Appendix A shows the interpreted potentiometric surface in and around the
CVOC plume(s) associated with the Tutu Wellfield Superfund Site in April 2010. The northern
and upgradient end of the plume is at the Curriculum Center near GWTF # 1. In this area, the
potentiometric contours (particularly at 175 feet above mean sea level) are interpreted by the
contractor (CDM) to bend in a way that suggests converging flow (toward the extraction wells).
However, the exact location and shape of these contours is not entirely supported by the water-
level data posted on the map (two of the four water levels posted upgradient of the 175-ft contour
are less than 175 ft). It is likely that the shape of the head contours reflects the conceptual model
of groundwater flow converging from the east and west into the bedrock valley that controls the
migration of the regional CVOC plume. In any case, the contours as drawn suggest that the
capture width from extraction wells RW-7 and RW-9 would be approximately 75 ft or less.
However, the 100-(ig/L CVOC plume is approximately 200 ft wide in this area. Water-level data
at approximately twelve wells in very close proximity to the extraction wells (within
approximately 100 ft of RW-7) could probably be analyzed in further detail on a zoomed-in map
to better define the shape of potentiometric contours and capture zone. For such an analysis,
measured water-levels at active extraction wells should not be used due to well losses. However,
this type of analysis could be complicated by vertical hydraulic gradients. It does not appear that
such an analysis would indicate a capture zone width greater than approximately 75 ft and
certainly it would be much less than 200 ft.
Based on the above review, the potentiometric-surface data presented for April 2010 suggest that
extraction at RW-7 (with intermittent extraction at RW-9 and RW-6) does not capture the entire
width of the CVOC plume.
Evaluation of CVOC Concentrations
Concentrations at most of the monitoring wells in the vicinity of GWTF #1 have decreased since
installation of the system (Table 4-1). The nearest monitoring wells downgradient of the GWTF
#1 extraction wells are MW-1D and RD-13. The total CVOC concentration at MW-1D has
decreased from 701 (ig/L to 125 (ig/L from 2004 to 2010. However, the concentration at RD-13
has shown very little decrease in that period: from 780 (ig/L to 736 (ig/L. RD-13 is screened
approximately 30 ft deeper than MW-1D. Wells on the western fringes of the plume
downgradient of the GWTF #1 extraction wells have shown either increasing concentrations
(MW-14) or slightly decreasing concentrations (MW-15).
The most likely explanation for these trends is that groundwater extraction at RW-7 (and
occasionally at RW-9 and RW-6) is capturing a portion of the highest-concentration CVOC
plume, but not all of the plume. Meanwhile, natural attenuation mechanisms (e.g.,
biodegradation, dispersion) are also slowly reducing dissolved-phase concentrations in some
areas such as along lateral plume edges. Portions of the plume exceeding 100 (ig/L, 500 (ig/L,
and probably even 1,000 (ig/L are apparently migrating beyond the extraction wells. The
interpreted CVOC concentration contours shown in Appendix A (CDM interpretation) do not
close or break at the extraction wells in a manner that would indicate capture.
This evaluation of CVOC concentrations near GWTF #1 suggests that capture from the
associated extraction system is incomplete.
15
-------
Table 4-1. Total CVOC Remediation from 2004 to 2010
Area
GWTF#1
(Northern Plume,
near source)
GWTF #2
(Northern Plume,
downgradient extent)
Southern Plume
Well ID
MW-1D
MW-13D
MW-14
MW-15
MW-2
MW-6D
MW-7
RD-13
RD-9
RD-5
TT-6
Tillett
MW-10D
MW-24
MW-8
DW-2
Eglin-3
MW-11D
MW-12D
RD-7
Delegard
Laplace
MW-2 ID
RD-1
RD-2
RD-3
RD-6
RD-8
Smith
Steele
2004 CVOC
Concentration
(HS/L)
701
0
11
55
11
31
1
780
152,020
204
165
100
48
26
44
16
33
0
71
74
12
24
72
6
1
4
8
14
11
169
2010 CVOC
Concentration
(HS/L)
125
2
23
39
1
2
19
736
15,211
70
28
36
3
2
2
1
48
4
12
7
1
5
31
1
0
0
0
3
4
85
Calculation of Expected Flow for Capture
Simple calculations can be made to estimate the flow that would be needed to fully capture the
plume. Such calculations are described in the USEPA guidance on capture-zone evaluation.
While the calculations assume ideal and non-realistic conditions (e.g., homogeneity, two-
dimensional porous-media flow, no recharge), they are informative for making initial
approximations of extraction rates required for hydraulic containment.
One of the simplest calculations provides an estimate of minimum flow (0 needed for capture of
a plume of known width (w) given uniform aquifer transmissivity (7) and hydraulic gradient (J):
Q = TJw. The aquifer transmissivity is the product of aquifer hydraulic conductivity and aquifer
thickness: T = Kb.
16
-------
For purposes of this evaluation, it is assumed that the target capture zone is the CVOC plume
greater than 100 (ig/L (total) at the Curriculum Center. It is assumed that lower concentrations of
CVOCs would be remediated by natural attenuation or captured in the downgradient system at
GWTF #2. The width (w) of the target capture zone is approximately 200 ft as measured from
the figure in Appendix A.
Using this same figure, the hydraulic gradient (J) is estimated to be 0.02 (10 ft head drop over
approximately 500 ft distance) on average at the Curriculum Center. However, the gradient
apparently increases toward the south and is somewhat uncertain. Therefore, calculations were
made using a reasonable range of hydraulic gradient between 0.015 (5 ft drop over 330 ft) and
0.025 (5 ft drop over 200 ft).
In a 2002 groundwater modeling report, CDM reviewed aquifer-test data and conducted
groundwater-model calibration to estimate aquifer characteristics. They estimated that the
productive portion of the bedrock aquifer in the Curriculum Center area has an effective hydraulic
conductivity (K) of 40 feet/day (ft/d). Recognizing that this is an uncertain estimate, a reasonable
hydraulic-conductivity range of 30 to 50 ft/d is used in making capture-zone flow calculations.
Based on the layer information presented by CDM (Appendix A) and based on boring logs and
well depth details, it appears that the upper, productive portion of the bedrock aquifer is
approximately 50 ft thick (from water table to base of productive zone). This thickness (b) is also
uncertain and variable, and a reasonable range of 30 to 70 ft is used in capture-zone flow
calculations.
Table 4-2 shows the calculation of transmissivity (7) and minimum flow required for capture (0
using best-estimate, low-end, and high-end values for hydraulic conductivity (K), aquifer
thickness (b), and hydraulic gradient (J).
It is noted that the best-estimate transmissivity (7) is in good agreement with the aquifer-test
results presented by CDM in their 2002 modeling report. As a best-estimate calculation by this
method, at least 42 gpm would be required to capture the plume at the 100 (ig/L CVOC level. If
low-end values are used for all input parameters, then the required flow rate would drop to 14
gpm (a very optimistic scenario). Conversely, if high-end assumptions are made, the required
flow would be 91 gpm (a very conservative scenario). A factor of safety of 1.5 to 2.0 is also
often applied to account for some of the simplifying assumptions associated with this capture
zone calculation method. This factor of safety, if applied would further increase the estimated
extraction rate required to provide capture of the 100 (ig/L contour.
The actual extraction rate averages 18 gpm at GWTF #1. By this analysis, this flow is adequate
for capture only if very optimistic assumptions are used for the input assumptions. Again, this
analysis suggests that, most likely, the plume is not being captured by the existing extraction
system at GWTF #1.
17
-------
Table 4-2. Calculation of Flow Required for Capture at Curriculum Center
Parameter
Hydraulic
Conductivity
Aquifer Thickness b (ft)
. . .. 7Xft2/d) =
Transmissivity . '
Hydraulic Gradient J
Target Capture f
Zone Width w
Q (ft3/d) =
Required Flow Rate
6 (gpm)
Low
Estimate
30
30
900
0.015
200
2700
14
Best
Estimate
40
50
2000
0.02
200
8000
42
High
Estimate
50
70
3500
0.025
200
17500
91
Comments
COM Modeling Report
(3/26/2002) (Table 2-2)
Review of Cross Sections,
Well Depths
Agrees with CDM
Modeling Report (Table 2-
1)
Measured from CDM
4/2010 Pot. Surf. Map
Measured from CDM
4/2010 Plume Map
Note: The above calculations do not include a factor of safety to account for simplifying assumptions
associated with this capture zone calculation.
4.2.1.2
Northern Plume Edge (GWTF #2) Plume Capture Evaluation
The total CVOC concentration at the GWTF #2 extraction well (RW-1S) is approximately 25
(ig/L, with only PCE above its RAL of 5 (ig/L. It is assumed in this discussion that a desired
outcome of GWTF #2 extraction is to capture the CVOC plume where the total CVOC
concentration is greater than 10 (ig/L. This would result in all CVOCs meeting (or very nearly
meeting) RALs at downgradient points.
Potentiometric Surface Evaluation
Review of the map in Appendix A indicates that there are insufficient water-level data in the
vicinity of RW-1S from which to draw a potentiometric surface of sufficient detail to evaluate
plume capture near GWTF #2.
Evaluation of CVOC Concentrations
Concentrations of CVOCs in monitoring wells downgradient of RW-1S have declined
significantly since 2004 (Table 4-1: e.g., MW-12D, RD-7). However, MW-12D continues to
have total CVOCs above 10 (ig/L. The declines in CVOC concentrations have been similar to
declines in wells upgradient of RW-1S (e.g., MW-10D, MW-8). It is therefore not clear whether
pumping at RW-1S is having a significant effect on groundwater CVOC concentrations at
downgradient wells MW-12D and RD-7.
Calculation of Expected Flow for Capture
As depicted in Appendix A, the width (w) of the 10-(ig/L plume is approximately 75 ft at RW-1S.
Using the same best-estimate assumptions for hydraulic conductivity (K = 40 ft/d), thickness (b =
50 ft), and hydraulic gradient (J= 0.02), as used for the calculation of capture flow at the
Curriculum Center, the estimated extraction rate required for capture is at least 16 gpm. This
estimate compares well with the actual average extraction rate of 18 gpm. However, the
extraction appears to be occurring at the western edge of the plume rather than at the center, and
18
-------
the eastern extent of the plume is uncertain. The 16 gpm estimate also does not account for a
factor of safety to address the simplifying assumptions associated with the calculation.
Therefore, it is not clear whether the 18 gpm extraction rate is sufficient for full capture of the of
the 10 (ig/L plume.
4.2.1.3 Combined Northern Plume Capture Evaluation
When initially designed, the extraction systems at GWTF #1 and GWTF #2 were expected to
work together in containing the entire northern portion of the CVOC plume (not including the
plume apparently originating at the O'Henry dry cleaning facility). CDM conducted modeling
evaluations to determine the design flow rates at the two facilities.
Review of Groundwater Modeling Results
Numerical groundwater modeling was previously conducted by CDM (in 2002) to evaluate
extraction rates necessary for plume capture. Numerical groundwater modeling overcomes many
of the simplifying assumptions required to apply simple calculations such as those described
above. Numerical modeling can result in more realistic estimates of capture, especially where the
hydrogeologic setting is complex and/or where extraction is distributed geographically to
different wells in a somewhat complex manner.
At that time of the CDM modeling analysis there were groundwater extraction systems operating
at the Texaco and Esso stations near the Curriculum Center. These two systems have since been
shut off.
CDM estimated through model scenarios that total extraction of between 30 and 36 gpm would
be required to capture the Northern Plume (Curriculum Center) (>100 (ig/L total CVOCs) during
"average" recharge conditions. The total extraction required during wet/peak recharge periods
was estimated to be between 63 and 73 gpm. This total extraction amount includes extraction at
the Curriculum Center, the two gasoline stations, and the Northern Plume Edge (near GWTF #2).
Currently, the total extraction at GWTF #1 and GWTF #2 is approximately 36 gpm, and is
consistent with the model-estimated extraction required for capture under average conditions.
While the estimated required total extraction rate is comparable to the current actual extraction, it
is not known if the particular placement of wells and extraction rates currently used would result
in modeled capture with the service-station extraction wells removed.
The RSE team did not conduct a comprehensive review of the model development and
calibration. The RSE team therefore cannot confirm the accuracy of the model predictions.
4.2.1.4 Overall Assessment of Capture
Based on the above evaluations, the weight-of-evidence approach to capture-zone evaluation
suggests the following:
Only a small part of the high-concentration portion of the CVOC plume is being captured
by the GWTF #1 extraction system at the Curriculum Center.
Capture of the 10-jig/L CVOC plume at RW-1S (GWTF #2) is uncertain.
19
-------
4.2.2 GROUNDWATER CONTAMINANT CONCENTRATIONS
Groundwater concentrations of CVOCs have declined significantly with the SVE and
groundwater extraction implementation (2004 versus 2010 data) across the site. Table 4-1 shows
total CVOC concentrations from March 2004 (Baseline) and April 2010 at various wells
associated with GWTF #1, GWTF #2 and the Southern Plume (O'Henry's plume).
However, recent progress to reach RAOs has been relatively stalled with concentrations
remaining elevated and stable at many wells. For example, the CVOC concentration at RD-9
remains over 15,000 (ig/L, the CVOC concentration at RD-13 has remain unchanged at 700 (ig/
for approximately six years, and concentrations at MW-14 and MW-15 have remained relatively
constant at levels in the 10 (ig/L to 50 (ig/L range.
4.2.3 INSTITUTIONAL CONTROLS TO PREVENT USE OF IMPACTED
GROUNDWATER
The following description is provided in the 2009 Five-Year Review regarding the procedures for
preventing use of impacted groundwater:
The remedy included institutional controls [ICs] in the form of Governmental
controls and/or proprietary controls to prohibit unauthorized use of groundwater
or the installation of new wells including decommissioning of existing domestic
and commercial wells within the confines of the groundwater plume. In March
2003, the VI Government prepared and 1C workplan pursuant to the executed
State Superfund Contract to implement appropriate governmental and/or
proprietary controls on these properties. This 1C workplan cited specific local
laws to prohibit withdrawal or removal of any water and soil without first
obtaining a permit from the Commissioner ofDPNR. As of April 2009, the 1C
workplan has been implemented with the exception of seven wells which were
identified in the 1C workplan. These wells were installed prior to the enactment
of these local laws. EPA is working closely with the VI government to ensure
that the owners of these wells will comply with pertinent local laws.
Allegedly, illegal pumping of private wells for irrigation and commercial purposes has been
occurring in wells located in the plume areas.
4.2.4 SOIL VAPOR EXTRACTION/VAPOR INTRUSION
As previously noted, GWTF #1 is equipped with SVE capabilities which are no longer used. The
SVE system was in operation from 2004 to 2006 and included extraction points SVE-1 and RW-
7. The system operation was discontinued in April 2006 when mass removal had decreased and
the SVE system was no longer cost-effective. At that time, SVE influent concentrations had
significantly decreased since start-up and an asymptotic pattern was established.
In December 2007, Lockheed Martin personnel under the Response, Engineering, and Analytical
Contract (REAC) installed and sampled 16 soil vapor intrusion monitoring points under the floor
of the Curriculum Center building. Of these 16 locations, three were installed in the maintenance
20
-------
area, nine in the warehouse area, and four in the curriculum area. At the same time, 30 indoor air
samples were collected: three from the maintenance area, 12 from the warehouse area and 15
from the curriculum area. Also, two ambient air samples were collected. The analytical results
are presented in Table 4-3.
Table 4-3. Analytical Results of Vapor Intrusion Study
Location
Maintenance Area
Warehouse Area
Curriculum Area
Total
Sub-Slab Samples
# Samples
Collected
3
9
4
16
PCE
Exceed.
3
8
4
15
TCE
Exceed.
2
5
0
7
Indoor Air Sam
# Samples
Collected
3
12
15
30
PCE
Exceed.
2
0
0
2
pies
TCE
Exceed.
0
0
0
0
Note: PCE Action Levels: 100 pg/m for sub-slab; 10 pg/m for indoor air. TCE Action Levels: 5
[tg/m3 for sub-slab; 0.5 [tg/m3 for indoor air.
Soil vapor and indoor air sampling has not been conducted since 2007. The SVE equipment is
still at the site and potentially could be used for future operation of a vapor intrusion mitigation
system, if needed.
4.3 COMPONENT PERFORMANCE
4.3.1
GROUND WATER EXTRACTION SYSTEM
The groundwater extraction system consists of five Grundfos electric submersible pumps with
varying horsepower motors. At GWTF #1 during the reporting period from May 1, 2009 to April
30, 2010, RW-6 operated for 1.0 to 1.5 hours weekly and pumped approximately 520 gallons per
month. RW-7 pumped at approximately 15 gpm continuously and RW-9 was non-operational
during this reporting period. Through this reporting period, about 6.7 million gallons of
groundwater were extracted, bringing the total of groundwater extracted from system startup
through April 30, 2010 to 58.3 million gallons.
At GWTF #2, during the reporting period from May 1, 2009 to April 30, 2010, RW-1 was non-
operational and RW-1S pumped at an average rate of 16 gpm. Through this reporting period,
about 8.1 million gallons of groundwater were extracted, bringing the grand total of groundwater
extracted from system startup through April 30, 2010 to 51.3 million gallons.
4.3.2
TREATMENT SYSTEM FOR EXTRACTED WATER
During the operating period from May 1, 2009 to April 30, 2010, GWTF #1 was in operation 95.6
% of the time. Down-times were typically due to power losses. CVOCs are typically removed
by the air stripper to below detection limits. No significant operational problems were
encountered.
During this monitoring period, GWTF #2 was in operation 96.4 % of the time. Similarly to
GWTF #1, down-times were typically due to power loss. CVOCs are typically removed by the
air stripper to below detection limits. No significant operational problems were encountered.
21
-------
4.3.3 VOCs REMOVED BY SYSTEMS
The groundwater system at GWTF #1 currently has total VOC influent concentrations of
approximately 125 (ig/L which results in a mass removal of approximately 8 pounds (Ibs) per
year. The groundwater system at GWTF #2 currently has total VOC influent concentrations of
approximately 25 (ig/L, for a mass removal of approximately 1.5 Ibs per year.
4.4 COMPONENTS OR PROCESSES THAT ACCOUNT FOR MAJORITY OF
ANNUAL COSTS
Annual cost estimates for operating this remedy are summarized below (Table 4-4), based on
information provided by the site team and/or estimated by the RSE team based on discussions
with the site team.
Table 4-4. Annual Operations and Maintenance Costs
Item Description
CDM Project Management supporting USEPA
Arrowhead Fixed Fee
Project Management
Materials
TSG Labor
Power ($0.36/kWh.)
Equipment Costs
Annual Sampling
CLP Costs (well monitoring)
CLP Costs (process monitoring)
Total Annual Operating Cost
Approximate Annual
Cost
$40,000
$279,600
$30,000
$33,600
$103,200
$105,600
$7,200
$13,000
$6,000
$13,000
$351,600
Notes: Italicized = cost included in Arrowhead's fixed fee.
kWh. = kilowatt hour
Additional details regarding these items are provided below.
4.4.1 PROJECT MANAGEMENT
CDM provides project management support to USEPA for approximately $40,000 per year. This
value does not include water supply or technical and litigation support. Arrowhead also provides
$30,000 of project management type services (see Section 4.4.2).
22
-------
4.4.2 ARROWHEAD FIXED FEE
CDM contracts Arrowhead for a fixed monthly fee of approximately $23,300 per month
($279,600 per year). From the fixed fee, Arrowhead pays TSG approximately $8,600 per month
($103,200 per year) for operating the systems. Approximately $2,500 per month ($30,000 per
year) is used towards Arrowhead's project management, data validation, and engineering support.
4.4.3 MATERIALS
Materials cost approximately $2,800 per month ($33,600 per year) of which acid is about $800
per month ($9,600 per year) and anti-scale is about $1,200 per month ($14,400 per year).
4.4.4 UTILITIES
The major utilities associated with both systems are electrical costs. This along with a few other
utility costs is approximately $8,800 per month ($105,600 per year). Currently, the rate for
electricity on the island is approximately $0.36 per kWh, which translates to an approximate
electricity usage of 290,000 kWh per year. The air stripper blowers (15 HP at GWTF #1 and 5
HP at GWTF #2) are the largest users of power. The 15 HP blower uses approximately $45,000
per year of power assuming the motor is operating at about 75 % efficiency.
4.4.5 SAMPLING
Annual sampling is conducted by Arrowhead with TSG assistance and costs approximately
$13,000 per year for sampling 30 wells. Additional analysis costs include $6,000 per year
Contract Laboratory Program (CLP) costs for groundwater monitoring and $13,000 per year for
process monitoring.
4.5 APPROXIMATE ENVIRONMENTAL FOOTPRINTS ASSOCIATED WITH
THE REMEDY
Direct energy usage for the site includes electricity and diesel/gasoline associated with materials
transportation. The large majority of the energy use is associated with electricity use, which is
generated from combustion of fuel oil. Based on emissions factors from the National Renewable
Energy Laboratory Life-Cycle Inventory Database (www.nrel.gov/lci), each kWh of electricity
generated from combusting oil emits approximately 2 Ibs of carbon dioxide, 0.002 Ibs of nitrogen
oxides, and 0.0005 Ibs of sulfur dioxides. Using these values, the approximate 290,000 kWh of
electricity usage for the Tutu Wellfield Superfund Site results in the emission of 580,000 Ibs of
carbon dioxide, 580 Ibs of nitrogen oxides, and 145 Ibs of sulfur oxides each year. Actual
emission factors are likely higher if resource extraction and transmission and distribution losses
are considered.
23
-------
Monthly system effluent air samples are collected to ensure compliance with the Air Pollution
Control Permit. The constituents monitored include PCE, TCE, cis-l,2-DCE and vinyl chloride.
Emissions of other pollutants may also be of concern, but these common pollutants were selected
because emissions information is more readily available for them and they may be adequate
indicators for other potential air emissions. Air emissions due to operation and maintenance of
both groundwater systems are summarized in Tables 4-5 and 4-6.
Table 4-5. Summary of GWTF #1 Air Emissions
Constituent Emitted into Atmosphere
PCE emissions
TCE emissions
cis-l,2-DCE emissions
Vinyl Chloride
Emissions
(Ibs/yr)
4.43
0.43
3.21
0.14
Note: PCE, TCE, and Vinyl Chloride are carcinogens.
Values based off of daily emission rates for May 2009 through April 201 Ofrom April 2010
Annual Remedial Action Progress Report (CDMFederal Programs Corporations) -
October 2010.
Table 4-6. Summary of GWTF #2 Air Emissions
Constituent Emitted into Atmosphere
PCE emissions
TCE emissions
cis-l,2-DCE emissions
Vinyl Chloride
Emissions
(Ibs/yr)
<0.97
<0.16
<0.33
<0.05
Note: PCE, TCE, and Vinyl Chloride are carcinogens.
Values based on daily emission rates for May 2009 through April 2010 from April 2010
Annual Remedial Action Progress Report (CDM Federal Programs Corporations) -
October 2010.
With respect to water usage, essentially all of the water use is from the groundwater extraction
systems. The water that is extracted and treated from these systems is discharged into the storm
sewer, and therefore is unavailable as a resource for groundwater usage.
Waste disposal associated with this remedy is minimal. With respect to more qualitative issues,
the remedy does not cause any significant aesthetic issues (noise, visual, odor) and there are no
major traffic issues associated with the remedy that would impact the surrounding land or
ecosystems.
4.6 RECURRING PROBLEMS OR ISSUES
Allegedly, illegal pumping of private wells for irrigation and commercial purposes has
been occurring in wells located in the plume areas.
USVI Water and Power Authority (WAPA) power outages.
24
-------
4.7 REGULATORY COMPLIANCE
During the RSE process, the site team did not report any exceedances of discharge standards or
other compliance related standards other than some minor pH excursions.
4.8 SAFETY RECORD
During the RSE process, the site team did not report any health and safety concerns or incidents
related to the remedial activities.
25
-------
5.0 EFFECTIVENESS OF THE SYSTEMS TO PROTECT HUMAN
HEALTH AND THE ENVIRONMENT
5.1 GROUND WATER
The following protectiveness statement was included in the 2009 Five-Year Review:
Implemented actions protect human health and the environment in the short term.
Currently, there are no exposure pathways that could result in unacceptable risks and
none are expected, as long as the site use does not change and the implemented
engineered and institutional controls are properly operated, monitored, and
maintained.
However, in order for the site to be protective in the long term the (following issues)
need to be resolved:
The source area Institutional Controls (ICs) not fully implemented.
Full remediation of the groundwater is uncertain.
Some monitoring wells are damaged.
The site team alleged that there is probably illegal pumping of private wells for irrigation and
commercial purposes in the plume area.
5.2 SURFACE WATER
The site team reported that sampling at the surface water discharge point indicated no detection of
CVOCs. The RSE did not focus on surface water.
5.3 AIR
The RSE team noted that based on a study completed in 2007, vapor intrusion is a potential issue
in the warehouse/Curriculum Center. Vapor intrusion is not likely to be an issue at other
buildings based on the decreased concentrations downgradient of the Curriculum Center.
5.4 SOIL
Not addressed as part of the RSE.
5.5 WETLANDS AND SEDIMENTS
Not addressed as part of the RSE, but not expected to be a concern.
26
-------
6.0 RECOMMENDATIONS
Cost estimates provided herein have levels of certainty comparable to those done for CERCLA
Feasibility Studies (-30 %/+50 %), and these cost estimates have been prepared in a manner
consistent with USEPA 540-R-00-002, A Guide to Developing and Documenting Cost Estimates
During the Feasibility Study, July, 2000.
The estimated effects on costs and green remediation associated with the recommendations
provided in this section are summarized in Tables 6-1 and 6-2, respectively.
6.1 RECOMMENDATIONS TO IMPROVE EFFECTIVENESS
6.1.1 HYDRAULIC CONTAINMENT
As indicated in Section 4.2.1, the interpreted capture zone associated with GWTF #1 is small
relative to the size of the high-concentration portion of the plume (e.g., greater than 100 (ig/L
CVOCs). RW-7 is too far upgradient to effectively contain the Curriculum Center source area. A
new containment system including a line of wells perpendicular to the flow direction screened
through the shallow and deep zones near RD-13 (300 ft downgradient) should be considered. The
plant is designed for up to 60 gpm so additional flow can be taken.
Based on preliminary calculations/evaluations presented in Section 4.2.1, the total extraction rate
required to capture the 100-(ig/L CVOC plume is approximately 50 gpm. This is based on the
best-estimate calculation of capture flow presented in Table 4-2, with a safety factor of 1.2. It is
also consistent with total extraction rates estimated in prior groundwater modeling (CDM 2002;
50 gpm is between flows required for average and wet/peak conditions).
To attain 50 gpm extraction, approximately four new extraction wells are likely to be needed,
each capable of pumping up to approximately 18 gpm (similar to the extraction rate at existing
well RW-7). This will allow 50 gpm to be attained when one well is offline for maintenance.
The number and spacing of wells to add should be evaluated based on: (1) review of the available
geologic information and the currently available hydrogeologic data (e.g., boring logs for
existing/past nearby monitoring and pilot scale treatment wells and historical water level data
under operating conditions); and (2) field testing (e.g. specific-capacity testing) of the new wells
during installation. The new extraction well system should be designed to attain capture of the
high-concentration portion of the CVOC plume; this will also address deep contamination that
slowly partitions upward into the capture zone of the extraction system.
The addition of four new extraction wells would cost approximately $180,000. This includes
drilling four approximately 100 ft deep extraction wells, well pumps, vaults, and installing piping
and conduit to each well (approximately 300' from GWTF #1). We include an assumed 50%
premium for doing this work and other work in the USVI. Operating and sampling the additional
extraction wells would require approximately $15,000 per year which is mainly for power for the
pumps. The existing air stripper is sized for the increased flow rate.
27
-------
In addition to installing a new containment system, it is recommended that two monitoring wells
be installed east of the depicted plume where data to define plume extents are lacking. This
would cost approximately $30,000. Potential locations for two new monitoring wells are: (1)
approximately 150 ft southeast of existing well RD-5; and (2) approximately 150 east of existing
well MW-10D (see Appendix A for existing well locations). The number and location of new
monitoring wells can be adjusted based on access restrictions, availability of groundwater
concentration information not reviewed during this RSE, or other available hydrogeologic
information.
Monitoring costs for these new wells can be offset by removing redundant existing wells from the
sampling program such as RD-1, RD-2 and RD-6.
6.1.2 No ADDITIONAL DOWNGRADIENT ACTIVE REMEDIATION
The site team has not actively contained or treated groundwater impacts from the O'Henry's
remaining source. CVOC concentrations at the Steele well and wells further downgradient have
decreased over time and the plume size has decreased. The site team has analyzed for natural
attenuation parameters to help determine the biological portion of the plume reduction. The site
team has put controls in place to protect potential receptors in this area. We do not recommend
changes in the current approach. Improved containment at GWTF #1 may increase the rate of
concentration decreases. If continued monitoring does not show continued decreases in plume
size, the site team could consider further investigation and remediation (perhaps chemical
oxidation or enhanced bioremediation at the O'Henry's site).
6.1.3 VAPOR INTRUSION RESAMPLING
Vapor intrusion was detected in the Curriculum Center during a December 2007 sub-surface and
indoor air sampling event. Sub-slab CVOC concentrations were elevated above screening
guidance levels for sub-slab and indoor air concentrations for most locations sampled and indoor
air quality samples in the maintenance area were elevated. Sampling has not been conducted
since the 2007 event and would be worthwhile to determine if conditions have improved or
degraded. A similar study with up to 12 sampling points for sub-slab and indoor air
concentrations should be considered. If indoor air levels are found above standards, a mitigation
system or other controls should be considered (components from the mothballed SVE system
could potentially be used). The RSE team defers to the site team for costs of conducting this
investigation because the site team likely has cost information associated with the 2007 event.
For cost evaluation purposes, we assume the study would cost $45,000.
6.1.4 SAMPLING PARAMETERS
MTBE should be added to the sampling parameters for the next annual event at a cost of less than
$1,000. If MTBE is found at levels of concern in monitoring wells, further analysis will be
needed to determine additional investigation and remediation approaches. For cost evaluation
purposes, we assume MTBE will not be found at elevated levels.
28
-------
6.2 RECOMMENDATIONS TO REDUCE COSTS
6.2.1 IMPROVE CONTRACTING EFFICIENCY
Electricity costs should not be part of the fixed-fee payment. Arrowhead has no control over the
unit cost for power and will have to put a factor of safety and markup in to cover unexpected
increases. CDM will also mark this cost up. With an assumed 5% markup by Arrowhead, 5%
contingency by Arrowhead, and 5% markup by CDM, removing power from the fixed-fee
payment could save approximately $15,000 per year.
Three levels of contracting are excessive and having both CDM and Arrowhead provide project
management should not be necessary. Eliminating or substantially reducing the project
management from one of these parties should result in savings of approximately $30,000 per
year. CDM has provided the RSE team with a cost for project management but not for litigation
support and community issues. The RSE team therefore cannot comment on the litigation
support and community related services provided by CDM or the cost for those services.
Because of the projected April 17, 2013 date for turnover of O&M responsibility to the US VI
DPNR/DEP, we understand that USEPA's contracting requirements would not allow cost savings
prior to the turnover date. We also understand that the USEPA cannot pay the electrical costs
directly. This recommendation, therefore, is made to potentially benefit the USVI DPNR/DEP;
the cost savings shown in Table 6-1 reflect a change made in 2013.
6.2.2 CONSIDER SHUT DOWN OF GWTF #2
GWTF #2 is located at the downgradient end of the Curriculum Center (northern) plume.
Groundwater extraction and treatment at GWTF#2 appears to provide little benefit to controlling
plume migration or restoring the aquifer. Concentrations in wells upgradient (MW-8 and MW-
10D) and downgradient of RW-1S (RD-7 and MW-12D) have a similar declining trend
suggesting that the effects of RW-1S to restore the aquifer may be limited. Concentrations at
RD-7 already meet RALs and concentrations at MW-12D nearly meet RALs already (the
measured PCE concentration in April 2010 was 8.1 (ig/L and the RAL is 5 (ig/L; all other RALs
were met). With more effective capture at GWTF #1, the concentrations near GWTF #2 will
decline even further. The site team should consider a temporary shutdown of GWTF#2 to
evaluate if it is providing meaningful remediation prior to GWTF #1 modifications. CVOC
concentrations at MW-12D and RD-7 could be monitored to determine if the decreasing trends
continue with GWTF #2 pumping suspended.
GWTF #2 should not be needed and operation should be terminated after GWTF # 1
improvements are completed and hydraulic containment is confirmed by reduced downgradient
concentrations. After shutdown, monitoring frequency should be temporarily increased at MW-
12D and RD-7 (e.g. monthly for six months) to ensure that CVOC concentrations do not increase
significantly as a result of shutdown. Though not expected, if concentrations do increase
significantly at MW-12D or RD-7, GWTF #2 could be restarted.
When modifications to GWTF #1 are complete, that system will provide effective capture of the
Curriculum Center source. With effective capture at GWTF #1, the GWTF #2 influent will
continue to decline. If not already terminated, GWTF #2 operation should be terminated as soon
as GWTF #1 improvements are completed and hydraulic containment is confirmed by reduced
29
-------
downgradient concentrations (based on sampling at MW-12D and RD-7). Assuming there is a
savings of $30,000 in power, $10,000 in project management, $15,000 in materials and
equipment, and $5,000 in analysis, termination of GWTF #2 operation could save $60,000 per
year.
6.2.3 OPERATION AND MONITORING
Based on substantial experience in operating air stripping systems and in reviewing over 50 Fund-
lead P&T systems, the RSE team believes that daily site visits are excessive for the treatment
systems at this site. Once or twice weekly would suffice. Reducing this frequency of system
checks should reduce operator costs from $8,600 per month to about $4,000 per month for
operating two systems and possibly less for one system.
Because of the projected April 17, 2013 date for turnover of O&M responsibility to the USVI
DPNR/DEP, we understand that USEPA's contracting requirements would not allow cost savings
prior to the turnover date. This recommendation, therefore, is made to potentially benefit the
USVI DPNR/DEP; the cost savings shown in Table 6-1 reflect a change made in 2013.
Well gauging frequency should be decreased from monthly to quarterly. Monthly data does not
appear to be used for determination of system effectiveness. Quarterly gauging will provide
sufficient information for system operations.
6.2.4 ELIMINATE GWTF EMISSIONS SAMPLING
Monthly air emission sampling at GWTF #1 is not needed. Like GWTF #2, air emission mass
calculations at GWTF #1 should be based on the assumption that 100% of VOCs in water are
removed by the air stripper. Eliminating this monthly air sampling would save approximately
$5,000 per year in analysis costs. As an alternative, reducing the sampling frequency to quarterly
(as proposed by the site team) is a reasonable approach that will save about $3,300 per year.
6.3 RECOMMENDATIONS FOR TECHNICAL IMPROVEMENT
Removing the excess pipe between the air stripper discharge and stack will reduce the friction
loss and the blower head required. This should allow for a smaller (about 10 HP) unit to be used
to replace the existing 15 HP unit even with the suggested increased flow associated with
Recommendation 6.1.1. This is a technical improvement as well as a cost reduction factor
because a 10 HP unit would reduce electricity usage by approximately 44,000 kWh per year,
resulting in savings of approximately $15,000 to $16,000 per year. Changing the blower size
might cost up to $10,000, so this modification should pay for itself in less than a year. A variable
frequency drive (VFD) could be installed for the existing blower for a similar cost and cost
reduction. If operation is expected to continue for many years beyond the expected 2013 turnover
to USVI DPNR/DEP direction, following optimization of the extraction system (assume to be
complete by 2013) the site team should consider replacing the tray unit air stripper with a packed
tower including an approximate 2 HP fan based on packed tower vendor estimates. This would
be an initial investment of approximately $60,000 and an additional yearly savings of $25,000 in
electricity usage.
30
-------
Prior to making any changes, the air stripper design for the proposed extraction system should be
evaluated based on proposed influent flow rates and concentrations to confirm blower
requirements. The current tray air stripper is cleaned by acid washing approximately twice per
year. Cleaning the packing in a tower-type air stripper can be done by periodic acid washings.
Acid is available at the system and cleaning labor should be similar to the tray unit.
6.4 CONSIDERATIONS FOR GAINING SITE CLOSE OUT
In-situ source treatment (enhanced reductive dechlorination [ERD]-bioremediation) was
considered by the site team but rejected due to high velocity preferential flow in fractures and
back diffusion of contamination from smaller fractures and primary porosity. These same
properties limit most in-situ technologies. Steam injection or other forms of heating would be a
potential consideration for the site but it is extremely expensive, energy intensive, and would
have a price premium on St. Thomas. The source area is approximately 500,000 cubic feet, and it
is reasonable to assume that thermal remediation of this volume might require $3,000,000. This
translates to over eight years of operation of the existing P&T systems or 15 to 20 years of
operation of an optimized P&T remedy. Although thermal remedies have been successful in
some applications, DNAPL contamination in bedrock is a challenging problem, and despite the
substantial investment of a thermal remedy at this site, aquifer restoration or discontinuation of
the P&T systems would not be guaranteed. The RSE team agrees that alternative technologies
are not appropriate for further consideration at this time. The RSE team believes that focusing on
improving containment at GWTF #1 is the key to reducing downgradient impacts and that GWTF
#2 may not need to continue operating for much longer. A limited in-situ technology ERD action
or in-situ chemical oxidation could be considered in the O'Henry's area if concentrations in this
area persist several years after the improvements at GWTF #1 are made.
Table 6-1 summarizes the recommendations and associated change in annual costs discussed
previously.
6.5 RECOMMENDATIONS FOR IMPROVED GREEN REMEDIATION
6.5.1 WATER DISCHARGE
Treated water meeting drinking water standards is currently discharged to the storm sewer even
though water is a precious commodity on St. Thomas. The water could be used for irrigation or
commercial (car washing or laundromat) purposes nearby. The site team (including DPNR)
should make further efforts to have the discharged water accepted for another use. This could
possibly help eliminate illegal pumping of private wells for irrigation and commercial purposes.
6.5.2 ALTERNATIVE ENERGY SOURCES
Power costs are extremely high on St. Thomas and alternative energy sources including solar and
wind should be considered to potentially offset power use at GWTF # 1. The payoff of capital
costs for these systems should be evaluated against the potential reduced power costs. At an
-------
approximately cost of $70,000 for a lOkW photovoltaic system and electricity savings of
approximately $5,000 per year, a photovoltaic system will have a payback period of
approximately 14 years and will not be an attractive investment unless substantial incentives or
subsidies are provided. The costs and potential savings for a wind system are more variable and
would require additional study to determine cost effectiveness. A feasibility study, including a
cost analysis, for a wind energy system should be approximately $5,000. If the results are
favorable, field information could be collected to confirm results prior to making the investment.
Table 6-2 provides a green remediation summary for the recommendations provided in this
report.
32
-------
Table 6-1. Recommendations Cost Summary Table
Recommendation
1 . Section 6.1.1 - New
containment system
(assume four new
extraction wells)
2. Section 6.1.1 - New
monitoring wells to the
East (assume two wells)
3. Section 6. 1.3 -VI
resample
4. Section 6.2.1 - Eliminate
redundant PM
(Arrowhead/CDM) and
assumed 5% markup on
TSG***
5. Section 6.2.1 - Remove
power from fixed cost
(USEPA pay directly)***
6. Section 6.2.2 -
Termination of GWTF
^2***
7. Section 6.2.3 - Decrease
daily site visits/gauging
frequency* * *
8. Section 6.3 - Remove
excess pipe between air
stripper discharge and
stack/install smaller HP
unit.
9. Section 6.3 - Replace
tray unit with a packed
tower consisting of a 1 or
2 HP fan.***
10. Section 6.2.3 - Air
Emissions Sampling
Reduction
Reason
Effectiveness
Effectiveness
Effectiveness
Cost-
Effectiveness
Cost-
Effectiveness
Cost-
Effectiveness
Cost-
Effectiveness
Technical
Improvement
Technical
Improvement
Cost-
Effectiveness
TOTAL
Additional
Capital
Costs ($)
180,000
30,000
45,000
0
0
0
0
10,000
60,000
0
325,000
Estimated
Change in
Annual Costs
($/yr)
15,000
0
0
(30,000)
(15,000)
(60,000)
(55,200)
(15,000)
(25,000)
(3,300)
(188,500)
Estimated
Change in
Life- Cycle
Costs
$*
480,000
30,000
45,000
(540,000)
(270,000)
(1,080,000)
(993,600)
(290,000)
(390,000)
(66,000)
(3,074,600)
Estimated
Change in
Life-Cycle
Costs (net
present value)
$**
403,163
30,000
45,000
(338,920)
(194,460)
(777,840)
(715,613)
(213,163)
(264,100)
(49,096)
(2,075,029)
Costs in parentheses imply cost reductions
* assumes 20 years of operation starting in mid-2011 with a discount rate of 0% (i.e., no discounting)
** assumes 20 years of operation with a discount rate of 3% (P/A = 14.8775)
*** assumes savings start in mid-2013 after GWTF#1 extraction is optimized and USEPA contracting ends
(P/A= 12.964)
33
-------
Table 6-2. Green Remediation Summary Table for Recommendations
Recommendation
Reason
Effects on Green Remediation
1. Section 6.1.1-New
containment system
(assume four new
extraction wells)
Effectiveness
Minor effects on footprints for all green remediation
core elements for installation of extraction.
Relatively significant increase in energy use and air
emissions (e.g., -15%) due to increased electricity
usage to operate pumps. Increase in groundwater
extraction and discharge to the storm sewer.
2. Section 6.1.1- New
monitoring wells (assume
two wells)
Effectiveness
Minor effects on footprints for all green remediation
core elements for installation of monitoring wells and
routine sampling.
3. Section 6.1.3-VI
re sample
Effectiveness
Minor effects on footprints for all green remediation
core elements associated with laboratory analysis of
samples.
Section 6.2.1 - Eliminate
redundant PM
(Arrowhead/CDM) and
assumed 5% markup on
TSG
Cost-Effectiveness
None
5. Section 6.2.1 - Remove
power from fixed cost
Cost-Effectiveness
None
Section 6.2.1-Hire TSG
directly
Cost-Effectiveness
None
7. Section 6.2.2 -
Termination of GWTF #2
Cost-Effectiveness
Significant reductions (e.g., -30%) in energy use and
air emissions due to reduced electricity usage.
Significant decrease in materials usage due to
reduced usage of anti-scale formula. Very significant
decrease (e.g., -50%) in groundwater extraction.
Section 6.1.1 - Decrease
daily site visits/gauging
frequency
Cost-Effectiveness
Minor decreases in energy and air emissions due to
decreased transport to the site.
9. Section 6.2.3 - Remove
excess pipe between air
stripper discharge and
stack/install smaller HP
unit.
Technical
Improvement
Significant reductions (e.g., -15%) in energy use and
air emissions due to reduced electricity usage.
10. Section 6.3 - Replace tray
unit with a packed tower
consisting of a 1 or 2 HP
fan.
Technical
Improvement
Very significant reductions (e.g., -40%) in energy
use and air emissions due to reduced electricity
usage. Minor materials use associated with
purchasing new equipment.
34
-------
APPENDIX A
SELECT FIGURES FROM SITE DOCUMENTS
-------
O'HENRY
FACILITY #1
(CURRICULUM
CENTER)
Groundwater Monitoring Well
Total CVOC Concentrations (ug/L)
0 0 - 9.99
S 10-99.99
100-1
500-
1,000-15,211
Not Sampled
128.57
170
10 ug/L
10 ug/L
Posted Groundwater Elevation
(feet above mean sea level)
Groundwater Elevation Iso-contours
(feet above mean sea level}
April 2010 Groundwater Total CVOC Concentration
Iso-contours (ug/L)
Baseline (April 2004) Groundwater Total CVOC
Concentration Iso-contours (ug/L)
Notes: 1. Groundwater samples were collected In April 2010.
2. Groundwater elevations were recorded In April 2010.
3. Only the groundwater elevations from wells spanning the
productive zone were used to develop Qroundwater
elevation Iso-contours.
Figure 2-1
Site-Wide Groundwater Elevations and CVOC Concentrations
, April 2010 RA Progress Report
Tutu Wellfield Site, St Thomas, USVI
COM
-------
RW-7
RF-8
TEW-1
RW-1
.
'
_ ....
-
: M^ii.
- . .-
OO <* O O O -4.SOO
OO O J.SOO
£3 O O 3 O O O
o
so o
Water Table
MATERIALS CROSS-SECTION AA
a.gy*-.; Productive Zone
*»j6tfet Non-Productive Zone
rest High-Gradient Zone
' Productive Zone
**m High Gradient Zone
* Productive Zone
:<'-*r---.i Productive Zone
NonProductive Zone
NonProductive Zone
Overljurden
Upland Areas
Lower Bedrock
CVOC (ug/L)
01/01/98 - 5/31/01
.000 - 10.000
ino.n - yoo.n
200.0 - 300.0
CROSS SECTION AA
* WATER SUPPLY WELL
* REMEDIATION WELL
TflTHIK 400.0 FT
-T- GROUND SURFACE
--__ TOP OF SCREEN
BOTTOM OF SCREEN
------- |