February 2012                                    EPA 530-R-10-003
             Conceptual Model Scenarios
          for the Vapor Intrusion Pathway
               Office of Solid Waste and Emergency Response
                 U.S. Environmental Protection Agency
                      Washington, DC 20460

-------
[This page intentionally left blank.]

-------
February 24, 2012                                                               Disclaimer
                                   DISCLAIMER

This document presents technical information on the phenomenon of subsurface vapor intrusion,
based upon EPA's current understanding. This document does not confer legal rights, impose
legal obligations, or implement any statutory or regulatory provisions. This document does not
change or substitute for any statutory or regulatory provisions. Interested parties are free to raise
questions and objections about the  appropriateness of the application of the examples presented
in this document to a particular situation. Finally, this is a living document and may be revised
periodically without public notice.  EPA welcomes public comments on this document at any
time and will consider those comments in any future revisions. Mention of trade names or
commercial products does not constitute endorsement or recommendation for use.
                                           in

-------
February 24, 2012
                      AUTHORS AND CONTRIBUTORS

The U.S. Environmental Protection Agency (EPA), Office of Resource Conservation and
Recovery (ORCR), Washington, DC, was responsible for the preparation of EPA's Conceptual
Model Scenarios for the Vapor Intrusion Pathway. Dr. Lilian Abreu, ARCADIS Inc., was the
primary author, with Dr. Henry Schuver, ORCR, as supporting author.

The authors wish to acknowledge the important contributions of Dr. William Wertz and Todd
McAlary, Geosyntec Consultants, Dr. Ian Hers, Golder Associates, and Dr. Paul Johnson,
Arizona State University, who provided review and suggestions for this technical report, as well
as RTI International who managed document reviews, editing, and preparation. Robert Truesdale
was the RTI Project Leader and Anne Lutes was the RTI technical editor. SRA International,
Inc., managed the external peer reviews.
                                         IV

-------
February 24, 2012                                                         Table of Contents


                                  Table of Contents
Executive Summary	ES-1
    ES.l  Purpose and Objectives	ES-1
    ES.2  Methodology, Assumptions, and Limitations	ES-2
    ES.3  Summary of Results	ES-2
1.0 Introduction	1
    1.1   Background	1
    1.2   Objectives	3
    1.3   Methodology	3
    1.4   Simulation Inputs, Assumptions, and Limitations	4
    1.5   Document Development and Peer Review	7
    1.6   Document Organization	7
2.0 Sources of Contaminated Vapors in the Subsurface	9
3.0 Vapor Transport and Fate in the  Subsurface	11
    3.1   Diffusive Transport of Vapors in the Unsaturated Zone	12
    3.2   Advective Transport of Vapors Near Building Foundations	15
4.0 Factors Affecting Vapor Migration and Indoor Air Concentrations of Recalcitrant
    VOCs	21
    4.1   Source Concentration	22
    4.2   Source Depth and Lateral  Distance from Building	25
    4.3   Other Conditions Simulated for Scenarios with Homogeneous Subsurface	31
          4.3.1   Multiple Buildings	31
          4.3.2   Permeable Fill and Building Pressurization	35
          4.3.3   Building Conditions	37
          4.3.4   Multiple Sources	40
    4.4   Subsurface Heterogeneities and Ground Cover	42
          4.4.1   Moisture Content in Layered Soils	42
          4.4.2   Lower Moisture Content Below the Building	47
          4.4.3   Heterogeneous Subsurface, Finite Sources, and Ground Cover	49
          4.4.4   Geologic Barrier	60
5.0 Factors Affecting Vapor Migration and Indoor Air Concentrations of Biodegradable
    VOCs	65
    5.1   Source Concentration	66
    5.2   Source Depth	72
    5.3   Source Lateral Distance from Building	76
    5.4   Moisture Content in Layered Soil	79
    5.5   Geologic Barrier	82
6.0 Temporal and Spatial Variability in Subsurface and Indoor Air Concentrations	85
    6.1   Transient Transport Following Source Release	85
          6.1.1   Effect of Moisture Content on Transient Transport	87
          6.1.2   Effect of Sorption  on Transient Transport	92
    6.2   Wind Load on Buildings	94
    6.3   Atmospheric and Indoor Air Pressure Fluctuations	97
    6.4   Seasonal Phenomena	101
          6.4.1   Fluctuations in Water Table Elevation	101

-------
February 24, 2012                                                        Table of Contents


          6.4.2  Rainfall Events and Water Infiltration	103
7.0 Examples Comparing Soil Gas Concentration at Different Locations	105
8.0 Summary of Results	109
9.0 References	Ill

Appendix A  Model Equations
Appendix B   Model Inputs and Assumptions
Appendix C   Document Development and Peer-Review Process
Appendix D  Variables Index


                                  List of Figures
         GENERAL VAPOR FATE AND TRANSPORT (SECTIONS 1.0 to 3.0)

1.    Conceptualized illustration of the vapor intrusion pathway	3

                            GENERAL SOIL VAPOR FLOW

2.    Direction of the vapor migration (due to diffusion) and resulting soil vapor
     concentration distribution for a groundwater vapor source (or NAPL at groundwater
     level)	13
3.    Direction of vapor migration (due to diffusion) and resulting soil vapor concentration
     distribution for a source in unsaturated soil (vadose zone)	14

              PRESSURE & VAPORS NEAR BUILDING FOUNDATIONS

4.    Change in pressure field distribution and soil gas flow rate (Qs) due to slab crack
     position and groundwater depth	16
5.    Soil vapor concentration distribution influenced by building pressurization and slab
     crack position	18
6.    Relationship between normalized indoor air concentration (a) and soil gas flow rate
     (Qs) into or out of the building	19

                RECALCITRANT HYDROCARBONS (SECTION 4.0)

              SOURCE CONCENTRATION AND FOUNDATION TYPE

7a.  Effect of source vapor concentration and foundation type on soil vapor distribution
     and indoor air concentration	23
7b.  Soil vapor concentration distribution and indoor air concentration from 7a presented
     as normalized values (i.e., the absolute values  in 7a were divided by the source vapor
     concentration)	24
                                          VI

-------
February 24, 2012                                                          Table of Contents


      SOURCE DEPTH AND LATERAL DISTANCE TO BUILDING (HOMOGENEOUS
                                     SUBSURFACE)

8.   Effect of groundwater source depth on soil vapor distribution and normalized indoor
     air concentration (a) for two foundation types	26
9.   Soil vapor distribution and normalized indoor air concentration (a) for a spatially
     finite vapor source laterally separated from building at two groundwater depths	27
10.  Soil vapor distribution and normalized indoor air concentration (a) for a spatially
     finite vapor source directly under a building at two groundwater depths	28
11.  Relationship between source-building lateral separation distance and normalized
     indoor air concentration (a)	29
12.  Soil vapor distribution and normalized indoor air concentration (a) for two spatially
     finite source types (unsaturated soil and groundwater) laterally separated from
     building	30

                MULTIPLE BUILDINGS (HOMOGENOUS SUBSURFACE)

13.  Soil vapor distribution and normalized indoor air concentration (a) for a scenario with
     two identical buildings separated by 10 m overlying a plume	32
14.  Soil vapor distribution and normalized indoor air concentration (a) for a scenario with
     two identical adjacent buildings overlying a plume	33
15.  Soil vapor distribution and normalized indoor air concentration (a) for a scenario with
     two adjacent buildings with different foundation types overlying a plume	34
16.  Soil vapor distribution for a scenario with two adjacent buildings under opposite
     pressurization, and with permeable backfill	36
17.  Normalized indoor air concentration (a) for different combinations of building
     conditions (e.g., pressurization, AER) and sub-slab vapor concentration	39
18.  Soil vapor distribution and indoor air (IA) concentration for a scenario with two
     buildings and two vapor sources	41

                           HETEROGENEOUS SUBSURFACE

19a. Full view of the soil layers used in the simulations presented in Figures 19b and 19c	43
19b. Effect of soil layers (19a) on pressure field, soil vapor distribution, and normalized
     indoor air concentration (a) for building under-pressurized by 5 Pa	44
19c. Effect of soil layers (19a) on pressure field, soil vapor distribution, and normalized
     indoor air concentration (a) for buildings over-pressurized by 5 Pa	45
20.  Soil vapor distribution and normalized indoor air concentration (a) for scenarios with
     different soil moisture content in the subsurface and below building	48
2la. Soil layers and ground cover scenarios used in the simulations presented in 21b with a
     shallow laterally separated vapor source	50
21b. Effect of soil layers and ground covers (21a) on soil vapor distribution and
     normalized indoor air concentration (a) for a shallow laterally separated vapor source	51
22a. Soil layer scenarios used in the simulations presented in 22b with a deep laterally
     separated vapor source	52
                                           vn

-------
February 24, 2012                                                         Table of Contents


22b. Effect of soil layers (22a) on soil vapor distribution and normalized indoor air
     concentration (a) for a deep laterally separated vapor source	53
23a. Discontinuous soil layers and ground cover scenarios used in the simulations
     presented in 23b for two buildings separated by 10 m overlying a plume	55
23b. Effect of discontinuous soil layers and ground cover (23a) on soil vapor distribution
     and normalized indoor air concentration (a) for two buildings separated by 10 m	56
24a. Discontinuous soil layers and ground cover scenarios used in the simulations
     presented in 24b for two adjacent buildings near a plume	58
24b. Effect of discontinuous soil layers and ground cover (24a) on soil vapor concentration
     distribution and normalized indoor air concentration (a) for two adjacent buildings	59

                                 GEOLOGIC BARRIERS

25.  Effect of geologic vapor barriers on soil vapor distribution and normalized indoor air
     concentration (a)	61
26.  Effect of a geologic vapor barrier on soil vapor distribution and normalized indoor air
     concentration (a) for two buildings separated by 10 m	62
27.  Effect of a geologic vapor barrier on soil vapor distribution and normalized indoor air
     concentration (a) for two adjacent buildings	63

 PETROLEUM AND OTHER AEROBICALLY BIODEGRADABLE HYDROCARBONS
                                       (SECTION 5.0)

                 SOURCE CONCENTRATION AND FOUNDATION TYPE

28.  Effect of source vapor concentration on hydrocarbon and  oxygen distribution in soil
     gas and normalized indoor  air concentration (a) for a building with basement	68
29.  Effect of source vapor concentration on hydrocarbon and  oxygen distribution in soil
     gas and normalized indoor  air concentration (a) for a slab-on-grade building	69
30.  Relationship between source vapor concentration and normalized indoor air
     concentration (a) for three biodegradation rates (X), two source depths and a building
     with basement	70
31.  Relationship between source vapor concentration and normalized indoor air
     concentration (a) for three biodegradation rates (X), two source depths and a slab-on-
     grade building	71

               SOURCE DEPTH AND LATERAL DISTANCE TO BUILDING

32.  Effect of source depth and vapor concentration on hydrocarbon and oxygen
     distribution in soil gas and  normalized indoor air concentration (a) for a slab-on-
     grade building	73
33.  Relationship between source depth and normalized indoor air concentration (a) for a
     building with basement, two source vapor concentrations, and three biodegradation
     rates (X)	74
                                          Vlll

-------
February 24, 2012                                                         Table of Contents


34.  Relationship between source depth and normalized indoor air concentration (a) for a
     slab-on-grade building, two source vapor concentrations, and three biodegradation
     rates (X)	75
35.  Effect of source depth and source-building lateral separation distance on the
     distribution of hydrocarbon and oxygen in soil gas for a NAPL source	77
36.  Relationship between source-building lateral separation distance and normalized
     indoor air concentration (a) for a NAPL source, two source depths, and three
     biodegradation rates (X)	78

                           HETEROGENEOUS SUBSURFACE

37.  Effect of layered soils (rows A-D) on hydrocarbon and oxygen distribution in soil gas
     and normalized indoor air concentration (a) for two building pressures (basement
     scenario)	80
38.  Effect of source vapor concentration on hydrocarbon and oxygen distribution in soil
     gas and normalized indoor air concentration (a) for scenarios with low permeability
     soils at the ground surface (e.g., soil  layer scenario on row D of 37)	81

                                 GEOLOGIC BARRIERS

39.  Effect of geologic barriers on hydrocarbon and oxygen distribution in soil gas and
     normalized indoor air concentration (a) for a NAPL source at 5m bgs	83
40.  Effect of geologic barriers on hydrocarbon and oxygen distribution in soil gas and
     normalized indoor air concentration for a dissolved groundwater source at 5m bgs	84

              TEMPORAL AND SPATIAL VARIABILITY (SECTION 6.0)

41.  Estimated time (y-axis, d=days) for chemicals to reach near-steady vapor
     concentrations (TSS) as a function of the distance from a source. Time on the plot is
     normalized by the retardation factor (Rv)	86
42.  Effect of transport time on soil vapor distribution and normalized indoor air
     concentration (a)  for different soil  pore water saturation (deep source, 8 m bgs)	88
43.  Effect of transport time on soil vapor distribution and normalized indoor air
     concentration (a)  for different soil  pore water saturation (shallow source,  3 m bgs)	89
44.  Effect of transport times on soil vapor distribution for scenarios with homogeneous
     lithology and layered soils, and multiple buildings over spatially finite vapor source	91
45.  Effect of transport time on soil vapor distribution and normalized indoor air
     concentrations (a) for scenarios with varying koc and foe	93

                                      WIND LOAD

46a. Effect of building wind load on ground surface and sub-slab gauge pressure
     distribution	95
46b. Effect of building wind load on sub-slab soil vapor distribution for recalcitrant and
     aerobically biodegradable VOCs	96
                                           IX

-------
February 24, 2012                                                         Table of Contents
             A TMOSPHERIC AND INDOOR AIR PRESSURE FL UCTUA TIONS

47.  Barometric pressure fluctuations used in the simulations presented in Figures 48
     through 51	98
48.  Temporal variation in the pressure difference between indoor air and sub-slab air
     resulting from fluctuations in barometric pressure (47) for two soil types	99
49.  Temporal reversal of the air flow direction resulting from fluctuations in indoor-sub-
     slab pressure difference (48)	99
50.  Temporal variation of the indoor air VOC concentration (y-axis) resulting from
     fluctuations in indoor sub-slab pressure difference and reversals of air flow direction
     (Figures 48 and 49)	100
51.  Temporal variation of the sub-slab VOC concentration (y-axis) resulting from
     fluctuations in indoor-sub-slab pressure difference and reversals of air flow direction
     (Figures 48 and 49). Concentration measured at location below slab crack	100

                            WATER TABLE FLUCTUATIONS

52.  Schematic illustration of water table fluctuations and the increase of VOC-impacted
     area from agroundwater source	101
53.  Schematic illustration of water table fluctuations and the increase of VOC-impacted
     area from avadose zone (unsaturated soil) source	102

     EXAMPLE SCENARIOS COMPARING SOIL GAS CONCENTRATIONS AT
                         DIFFERENT LOCATIONS (SECTION 7.0)

54.  Scenarios with extensive groundwater source directly below a building. The symbols
     highlight areas for comparing soil vapor concentrations	106
55.  Scenarios with a groundwater source  at different lateral distances from a building.
     The symbols highlight areas for comparing soil vapor concentrations	107
56.  Scenario with multiple buildings and  multiple sources. The symbols highlight areas
     for comparing soil vapor concentrations	108

-------
February 24, 2012                                                        Executive Summary
                              EXECUTIVE SUMMARY

Vapor intrusion occurs when volatile organic compounds (VOCs) from contaminated soil or
groundwater migrate upwards toward the ground surface and into overlying buildings through
gaps and cracks in foundation slabs or basement walls. The route VOCs take from a subsurface
source to the air inside a building is referred to as the vapor intrusion pathway.

Since the U.S. Environmental Protection Agency (EPA) published the 2002 EPA draft vapor
intrusion guidance (Draft Guidance for Evaluating the Vapor Intrusion to Indoor Air Pathway
from Groundwater and Soils; EPA530-D-02-004, U.S. EPA, 2002), the understanding of the
vapor intrusion pathway has grown substantially. This Conceptual Model Scenarios for the
Vapor Intrusion Pathway technical document expands on the understanding and
conceptualizations presented in that draft guidance document and those appearing subsequently
in the Interstate Technology and Regulatory Council's 2007 practical guideline (ITRC, 2007).

ES.1  Purpose and Objectives

The simulation results presented in this document are  intended to illustrate how different site and
building conditions might influence both the distribution of VOCs in the subsurface and the
indoor air quality of structures in the vicinity of a soil  or groundwater VOC source. Simulation
results are presented for a range of simplified scenarios to help vapor intrusion practitioners
visualize potential subsurface distributions of VOCs in soil gas and the relationship between
them; indoor air concentrations; and characteristics of the vapor source, chemicals of concern,
soils, and buildings, including their lateral and vertical (depth) position with respect to the
contaminant source or sources. In addition, the simulation results provide some insight into
spatial and temporal variability of soil gas and indoor  air concentrations. This information can
help practitioners develop more accurate conceptual site models, design better sampling plans,
and better interpret the results of site investigations.

VOC concentrations in soil gas attenuate, or decrease, as the VOCs move from the source
through the soil and into indoor air. The extent of attenuation is related to site conditions,
building properties, and chemical properties, and is typically quantified in terms of an
attenuation factor defined as the ratio of indoor air concentration to source vapor concentration.
The primary objective of this document is to provide simplified simulation examples of how
several factors (e.g., subsurface and building conditions) work together to determine (1)  the
distribution of VOC contaminants in the  subsurface and (2) the indoor air concentration  relative
to a source concentration. Factors addressed in this document include vapor source
characteristics (e.g., concentration, size, location, depth), subsurface conditions (e.g., soil layers,
moisture conditions, oxygen levels for biodegradation), and building characteristics (e.g.,
foundation type and condition, pressurization,  air exchange rates), as well as general site
conditions (e.g., wind, ground cover), and the range of simulations included here covers common
conditions encountered at sites where vapor intrusion  is a concern. Both aerobically
biodegradable petroleum hydrocarbons and other, more recalcitrant, contaminants that do not
readily biodegrade in the soil gas under natural aerobic conditions (i.e., chlorinated solvents) are
modeled, and the simulations include both single- and multiple-building scenarios, as well as
                                          ES-1

-------
February 24, 2012                                                        Executive Summary
transient conditions to investigate how soil gas and indoor air concentrations might vary with
time.

ES.2  Methodology, Assumptions, and Limitations

The work presented in this technical document features three-dimensional (3-D) mathematical
model simulations for a range of conceptual model scenarios. Although the model visualizations
presented in this document are based on a sound theoretical framework (Abreu, 2005; Abreu and
Johnson, 2005; 2006), they are by necessity  generated for simplified scenario inputs that may or
may not adequately represent the complexities found at real sites. Thus, these simulations (or any
use of the model described herein) are not intended to replace site-specific investigations. Rather,
the simulated visualizations should enable practitioners to plan better investigations of vapor
intrusion sites and to better interpret their results.

ES.3  Summary of Results

This document was prepared to help environmental practitioners gain insight into the processes
and variables involved in the vapor intrusion pathway and to provide a theoretical framework
with which to better understand the complex vapor fate and transport conditions typically
encountered at actual contaminated sites. Actual site-specific conditions may lead to more
complex VOC distributions than shown for the simplified conceptual model scenarios used in
this technical document. Nevertheless, the following general observations can be made from
these theoretical analyses and may be useful when considering  the vapor intrusion pathway at a
particular site. Report sections are provided  so the reader can review examples and understand
the basis and limitations for each observation:

    •   The horizontal and vertical distance over which vapors  may migrate in the subsurface
       (primarily by diffusion) depends on the concentration of the source (Sections 4.1 and
       5.1), the source depth (Sections 4.2 and  5.2), the soil  matrix properties (e.g., porosity and
       moisture content, Sections 4.4 and 5.4),  and the time since the release occurred (Section
       6.1)

    •   Subsurface heterogeneities in site geology (e.g., layering, moisture content; see Sections
       4.4, 5.4, and 5.5) influence the extent of vapor transport from a contaminant source to
       overlying or adjacent buildings.

    •   Advective flow occurs predominantly near cracks and openings in the building
       foundation slab and may affect the distribution of VOCs directly beneath the structure
       (Section 3.2). Heterogeneities in the permeability of geologic materials and backfill
       (Section 4.3.2), along with wind effects  and building and atmospheric pressure temporal
       variation, may contribute to spatial and temporal variability of VOC concentrations in
       sub-slab soil gas  and indoor air (Section 6).

    •   The distribution of VOCs in soil gas beneath a building is not the only factor that
       determines the indoor air concentration.  The indoor air VOC concentration is also
       influenced by building conditions, including the existence of cracks in the foundation,
       building pressurization, and air exchange rate, which in turn can be related to other
       factors such as temperature, wind, barometric pressure,  occupant behavior, and building
       operations (Section 4.3).
                                          ES-2

-------
February 24, 2012                                                         Executive Summary
    •   In cases where the subsurface is homogeneous, building conditions are the same (e.g., air
       exchange rate, pressurization), and the source vapor concentration extends evenly
       beneath each building, the presence of multiple single-family residences at typical
       spacing can have little or no effect on the predicted indoor air VOC concentration for a
       single building (Section 4.3).

    •   Simulations assuming an impermeable ground cover suggest that VOC concentrations in
       shallow soil gas can be higher under the low permeability ground covers than under open
       soil (Section 4.4.3).

    •   The soil gas concentration distribution of aerobically biodegradable petroleum
       hydrocarbons can be significantly different from that of chlorinated solvents, which are
       comparatively more recalcitrant and do not readily biodegrade in the soil gas under
       natural aerobic conditions (Section 5).

    •   The simulations presented in this document illustrate that VOC concentrations may not
       be uniform beneath a building slab and in the subsurface. Section 7 shows, for some
       different scenarios, how exterior soil gas samples may be similar to or different from the
       sub-slab concentration, depending on site-specific conditions and the location and depth
       of the soil gas sample.

The conceptual scenarios simulated in this document illustrate that there are  several factors
influencing the distribution of VOC concentrations in soil gas and in indoor air, and suggest that
assessment of the distribution of VOC concentrations in soil gas at sites and  in indoor air can be
supported by characterization of the site geology, building conditions, source extent,
biodegradation, and other site-specific factors that can influence the distribution of VOCs in the
subsurface and their migration into the indoor air of overlying buildings.

One of the key expected benefits of this document is to help practitioners visualize what to
expect under various site conditions so they can select samples judiciously in order to minimize
both the uncertainty and costs associated with vapor intrusion assessment.
                                           ES-3

-------
February 24, 2012                                                          Executive Summary
                             [This page intentionally left blank.]
                                           ES-4

-------
February 24, 2012                       Conceptual Model Scenarios of the Vapor Intrusion Pathway

1.0    Introduction
  This chapter provides context for the simulations that are included in the following chapters. It includes a
  discussion on the objectives and methodology used when developing the simulations and a discussion on the
  inputs, assumptions, and limitations of the simulations. There are no simulations in this chapter.
In November 2002, the U.S. Environmental Protection Agency (EPA) issued draft vapor
intrusion guidance (Draft Guidance for Evaluating the Vapor Intrusion to Indoor Air Pathway
from Groundwater and Soils; U.S. EPA, 2002) that was based on the understanding of vapor
intrusion at that time. Since then, the understanding of the vapor intrusion pathway has grown
substantially. This Conceptual Model Scenarios for the Vapor Intrusion Pathway document
expands on the understanding and conceptualizations presented in that November 2002 draft
guidance document and those appearing subsequently in the Interstate Technology and
Regulatory Council's (ITRC's) 2007 practical guideline (ITRC, 2007).1 Simulation results
presented in this document are intended to illustrate how different site and building conditions
might influence the distribution of VOCs in the subsurface and the indoor air quality of
structures in the vicinity of a soil or groundwater contaminant source. Simulation results are
presented for a range of simplified scenarios to help vapor intrusion practitioners visualize
potential subsurface soil gas distributions of VOCs and the relationship between them, indoor air
concentrations, and characteristics of the vapor source, chemicals of concern, soils, and
buildings, including their  lateral and vertical (depth) position with respect to the contaminant
source or sources. In addition, the simulation results provide some insight to spatial and temporal
variability of soil gas and indoor air concentration. This information can help practitioners
develop more accurate conceptual site models, design better sampling plans, and better interpret
the results of site investigations. The materials and analyses presented in this document are based
on complex mathematical simulations of contaminant fate and transport and intrusion into
buildings for simplified sets of model inputs. Care must be taken in interpreting and acting on the
simulation results presented in this technical document, as some aspects of this work have yet to
be studied in actual field settings (e.g., high frequency transient measurement studies are still
needed). Therefore, the intent in presenting the simulation results is to aid in conceptualization
and interpretation, not to replace appropriate site investigation.

1.1     Background

Vapor intrusion occurs when VOCs from contaminated soils or groundwater migrate upwards
toward the ground surface and into overlying buildings through gaps and cracks in foundation
slabs or basement walls. This contaminant migration is driven naturally by differences in
concentrations and air pressure between the subsurface contaminated areas and the affected
buildings. The route VOCs take  from a subsurface source to the air inside a building is referred
to as the vapor intrusion pathway. When VOCs present in soil gas migrate to the interior of a
building and reach concentrations that could pose a potentially unacceptable health risk, the
pathway is considered "complete."
1 This report was developed by EPA's vapor intrusion guidance development team for the Office of Solid Waste
  and Emergency Response. The primary investigator and author of the report was Dr. Lilian D.V. Abreu
  (ARCADIS U.S., Inc., San Francisco, CA) under contract to EPA.

-------
February 24, 2012                      Conceptual Model Scenarios of the Vapor Intrusion Pathway


The term "VOC" is used throughout this document because volatile organics are usually the
chemicals of concern at vapor intrusion sites, but semi-volatile organic compounds (SVOCs) and
elemental mercury can also volatilize and contaminate soil gas and indoor air by vapor intrusion.
Although the simulations presented in this document are based on representative VOC
properties, they are useful to qualitatively understand the vapor fate and transport of other vapor-
forming compounds. The terms "soil gas" and "soil vapor" are used interchangeably in this
document to refer to the medium through which VOC vapors move by diffusion from higher to
lower concentrations;  soil gas also carries contaminants wherever it moves, by advection (i.e.,
soil gas flow), in particular from the sub-slab region into buildings. Finally, the term "soil" is
used in this document to mean both the agricultural soil zone and the zone of unconsolidated,
unsaturated material beneath it, but above the water table.

VOC concentrations in soil gas attenuate, or decrease, as the VOCs move from the source
through the soil and into indoor air. This reduction in VOC concentration from a measurement
point in the subsurface to indoor air is referred to as attenuation and occurs because the VOC
emissions into a building are mixed with the natural flow of ambient air through the building.
The extent of attenuation depends on the emission rate into the building, and the emission rate
can be affected by the following:

    •   Subsurface features (e.g., fine-grained soils, high-moisture soil layers) that may hinder
       the diffusion and advection of VOCs

    •   Biodegradation of contaminants, which leads  to a decrease in the emissions along the
       vapor migration pathway

    •   The integrity of the foundation and sub-grade walls

    •   Changes with time in groundwater level, source strength, and infiltration rates

    •   Pressurization  of the building (under-pressurization draws soil gas into a building)

    •   Air exchange into a building, which brings fresh air into the enclosed space and dilutes
       the concentration of VOCs that enter through  the vapor intrusion pathway.

Johnson and Ettinger (1991) defined a parameter to relate the vapor concentration of a chemical
inside the building to its vapor concentration  at the subsurface source and called it the "vapor
intrusion attenuation factor," or "alpha" (a). It is defined as the concentration in indoor air
divided by the concentration in soil gas at some depth. In this document, the vapor intrusion
attenuation factor (a) is always defined as the indoor  air concentration (Cind00r) divided by the
soil vapor concentration immediately above the VOC source (CSOUrce}\ as such, a is a source-
normalized indoor air  concentration (i.e., actual indoor air  concentration divided by the source
concentration), as follows:
                                            r
                                        „ 	  indoor
                                       \Jfj —
                                             source

In this document, the source is defined as the region of highest vapor concentration; therefore,
the normalized indoor air concentration (a) is always less than one. Throughout this document,
we use the term "normalized indoor air concentration" in the text (periodically with a in
parentheses following), and a in the figures for brevity.

-------
February 24, 2012
                    Conceptual Model Scenarios of the Vapor Intrusion Pathway
1.2    Objectives

Vapor intrusion is an evolving field of science, and there is a need to expand the understanding
of this pathway beyond the simple conceptual model presented in Figure 1 (U.S. EPA, 2002),
which illustrates a source of contamination in soil and groundwater and indicates the upward
movement of VOCs from this source toward and into buildings. The work presented in this
technical document features three-dimensional (3-D) mathematical model simulations for a wide
range of conceptual model scenarios, with the objective of providing a theoretical basis for vapor
intrusion practitioners to better understand the processes and variables involved in the vapor
intrusion pathway and how they affect the distribution of soil vapor concentrations and soil vapor
intrusion into buildings. Although the model visualizations presented in this document are based
on a sound theoretical framework, they are by necessity generated for simplified inputs that may
or may not adequately represent the complexities found at real sites. Thus, these simulations (or
any use of the model described herein) are not intended to replace site-specific investigations.
Rather, the simulated visualizations presented in this document should enable practitioners to
plan better investigations of vapor intrusion sites and to better interpret their results.
       Indoor Air
     Soil Gas
(I     I     1     It     1     I     I     1
 ff^                     Chemical Vapor Migration
     Soil   	>
     Contamination
     (residual or
     mobile NAPL)      Dissolved GroundwaterCo^itamination

              Figure 1. Conceptualized illustration of the vapor intrusion pathway.
                                     (U.S. EPA, 2002)

1.3    Methodology

Most of the discussion and figures presented in this document were generated using a 3-D
numerical model that simulates the fate and transport of contaminants in the subsurface and
intrusion into buildings. The model was developed by Dr. Lilian D.V. Abreu and Dr. Paul C.
Johnson at Arizona State University (Abreu and Johnson, 2005, 2006; Abreu, 2005). Details of
the mathematical model development are presented in the cited publications and are not repeated
here. Briefly, the numerical model simultaneously solves equations for the soil gas pressure field
(from which the advective flow field is computed), advective and diffusive transport and reaction
of multiple chemicals in the subsurface, flow and chemical transport through foundation cracks,

-------
February 24, 2012                     Conceptual Model Scenarios of the Vapor Intrusion Pathway


and chemical mixing indoors. The model's equations are summarized in Appendix A. The
numerical accuracy of the code has been demonstrated through comparison of model predictions
with other analytical and numerical model results (Abreu and Johnson, 2005; Abreu, 2005;
Pennell et al., 2009; Bozkurt et al., 2009).  The model predictions for assumed recalcitrant
chemicals (i.e., chemicals with no or slow biodegradation in soil gas under natural aerobic
conditions) are consistent with field measurements summarized by Hers et al. (2003). Also, the
model predictions for aerobic biodegradation scenarios anticipate the key features of the field
data of sites presented in the literature (Abreu and Johnson, 2006; Davis, 2009). The model was
altered slightly from what is described in the sources cited above (see Appendix A): the indoor
air is still considered to be well mixed, but the mixing is no longer limited to steady-state
conditions as presented in Abreu and Johnson (2005, 2006) and Abreu (2005).

The Abreu and Johnson 3-D model is more complex than  the one-dimensional (1-D) Johnson
and Ettinger model, which has traditionally been applied for prediction of vapor intrusion
(Johnson and Ettinger, 1991; U.S. EPA, 2004). Johnson (2002; 2005) used the Johnson and
Ettinger model to provide insights on the effects of a variety of vapor intrusion pathway
variables on indoor air concentrations and on functional relationships between critical parameters
(e.g., soil conditions,  building cracks, the vertical separation between the source and the
building) and vapor intrusion attenuation factors. The current document uses the Abreu and
Johnson 3-D model to simulate several processes that cannot be simulated with the 1-D Johnson
and Ettinger model, such as effects of lateral source-building separation, finite sources, laterally
discontinuous soil layers, and coupled oxygen and chemical transport and biodegradation.

The Abreu and Johnson 3-D model calculates the chemical vapor concentration in the
subsurface, the mass flow rates into the building(s), and the indoor air concentration due to vapor
intrusion. To facilitate the discussion and the presentation of results, the model output has been
normalized using the source concentration (i.e.,  the maximum vapor concentration in the
subsurface). When the output is an indoor air concentration, we call this source-normalized value
the "normalized indoor air concentration"  or just "a" in the figures. When the output is soil vapor
concentrations, these are also presented as source-normalized values, called "normalized soil
vapor concentrations." In either case, the normalized concentrations shown in the figures can be
multiplied by the source concentration to convert them into absolute concentration values. The
contour lines in most of the  figures (2-D contour plots on vertical cross-sections through the
center of the building and horizontal plan views at a specified depth below ground surface [bgs])
show these normalized  soil vapor concentrations, which are always dimensionless and range
from 0 to 1, with 1 being equal to the concentration at the source.

1.4    Simulation Inputs, Assumptions, and Limitations

Unless specified  in the text and figures, the model input values common to all simulations (i.e.,
baseline conditions) are the  same ones used in the published work of Abreu and Johnson (2005,
2006). Detailed baseline inputs and assumptions are presented in Appendix B, along with the
conditions that are varied in the  simulations to show the influence of selected building, source,
and soil conditions. The physical-chemical properties of benzene were used in the simulations
because they are  similar to those for several compounds of interest in vapor intrusion.

-------
February 24, 2012                      Conceptual Model Scenarios of the Vapor Intrusion Pathway


The baseline conditions were selected to represent a typical size single-family home. Because
this technical document is intended to provide the practitioner with insight as to how key site
characteristics might affect vapor transport in the subsurface and vapor intrusion into buildings,
the homogeneous subsurface case was selected as the baseline to introduce the simplest case
first, before incorporating the complexities of layered and heterogeneous soils. The effects of
these more complex conditions are  also presented in this document (primarily in Section 4.4).

The baseline inputs used for the simulations in this document can be summarized as follows:

    •  A small residential building with a 1,000 ft2 (or about 100 m2) footprint with  a basement
       or slab-on-grade foundation that is cracked around the perimeter and has a steady under-
       pressurization of 5 pascals (Pa) relative to the atmosphere

    •  If the building is a multi-floor building, vapor intrusion and mixing in the lowest level

    •  Sandy homogeneous soils

    •  A constant strength and spatially extensive vapor source, and steady-state pressure and
       vapor transport  conditions

    •  Contaminants that do not readily biodegrade aerobically in the subsurface (i.e., assumed
       to be recalcitrant compounds in model simulations)

    •  A single vapor source located on top of the capillary fringe (from either a dissolved
       groundwater source or a non-aqueous-phase liquid [NAPL] plume source).

Appendix B presents detailed input values. Examples of conditions simulated that differ from
the baseline include the following:

    •  Cracks located at the centerline of the foundation

    •  Continuous and discontinuous soil layers

    •  Multiple buildings

    •  Finite-sized sources, multiple sources, and unsaturated zone sources

    •  Transient transport conditions

    •  Biodegradable contaminants.

Although the majority of the simulations examine the effects of different subsurface  conditions,
simulations were also performed to examine the effects of different building conditions.

The 3-D model used in this work simulates the transport of contaminant vapors in the
unsaturated soil zone; it does not model the transport of dissolved contaminants via groundwater
flow in the saturated soil zone, and  for these model runs, there was no net flow up or down of
soil moisture in the unsaturated zone (e.g., from infiltration or a rising water table). The
foundation floor and walls are treated as being impermeable barriers to the transport  of vapors
from the subsurface to the indoors,  except where there are cracks or openings in the foundation.
In actual foundations, the ability of concrete to hinder the transport of soil gas depends on the
physical integrity of the concrete and characteristics determined by cement mixtures,
cement/water ratios, and production processes (e.g., poured concrete vs. concrete block). Intact

-------
February 24, 2012                      Conceptual Model Scenarios of the Vapor Intrusion Pathway


concrete is virtually impermeable to air flow; nevertheless, volatile compounds from soil gas
may diffuse through a concrete slab at relatively low rates (Nielson et al., 1997; Renken and
Rosenberg, 1995; Rogers et al., 1994). The baseline conditions for most simulations presented in
this document assume a full-length perimeter crack, a building with a steady under-
pressurization of 5 Pa, relatively dry sandy soils, and a constant source concentration (i.e., no
depletion of the source). These inputs result in upper-bound diffusion coefficients and steady
flows into the building and so are thought to be conservative. To help put the results in context,
for simulations not involving aerobic biodegradation, the model-predicted normalized indoor air
concentrations (a) are consistent with site-specific measurements reported in the literature (Hers
et al., 2003; Johnson et al., 2002).

The current version of the 3-D model simulates buildings with basement or  slab-on-grade
foundations; it does not simulate buildings with a crawl space. A crawl space is a space between
the ground and the first floor of a building, but it is usually not high enough for a person to stand
upright. According to the U.S. Census Bureau (2006), about 26% of U.S.  single-family housing
units have a crawl space.  Soil vapor can also intrude into buildings with a crawl space.
According to Nazaroff and Nero (1988), the building substructure influences the degree of
pressure coupling between the indoor air and the soil vapor: the interior of a slab-on-grade
building or a basement is potentially well coupled to the nearby soil. A building with a crawl
space substructure may be well coupled or not, depending on (1) whether the crawl space is
vented and the extent of that ventilation, and (2) the presence and condition of any water vapor
barrier between the lowest floor in a building and the crawl-space. The contaminant transport
processes in the subsurface and the building factors affecting vapor intrusion that are described
in this technical document also apply to scenarios including buildings with crawl  spaces;
nevertheless, the vapor concentration distribution in the subsurface below the building and the
contaminant emission rates into the crawl space can differ if there is no foundation concrete slab
acting as a cap and a barrier for upward contaminant transport. Although the vapor
concentrations in the subsurface below  a crawl space could be lower than the ones below a slab-
floored basement or a  slab-on-grade foundation, the contaminant emissions  into the crawl spaces
could be higher.  The ventilation rate of the crawl space and the nature and condition of the crawl
space floor (e.g., concrete slab, concrete skim-coat, plastic water-vapor barrier, dirt) are key
parameters affecting the air concentration that may eventually intrude into the building above.

It should be emphasized that actual site conditions will vary from the simplified inputs used to
define the conceptual model  scenarios discussed in this document. As a result, actual VOC
distributions at field sites may be more  complex (i.e., spatially and temporally variable) than
those shown in this document. These simulations are presented as an aid to visualizing the
behavior of VOCs during vapor intrusion, which should improve a practitioner's ability to plan
effective vapor intrusion investigations  and  properly  interpret their results. Subsurface and
building heterogeneities, spatial and temporal variability, and possible interactions of subsurface
and building conditions are examples of site-specific information that should be considered along
with these simulations in the evaluation of the potential for vapor intrusion for any given site.

In a site assessment for vapor intrusion, any relevant background VOC levels (i.e., contaminants
in indoor air that come from  either indoor sources or from ambient [outdoor] air)  should be taken
into consideration. As a simplifying assumption, this work assumes that all VOCs in indoor air
are the result of vapor intrusion (i.e., all VOCs in indoor air come from a source in the

-------
February 24, 2012                     Conceptual Model Scenarios of the Vapor Intrusion Pathway


subsurface) and that there are no background VOC contributions from indoor sources or outdoor
air. In addition, indoor air concentrations are not assumed to be influenced by sorption (or
desorption) to building materials. The EPA document Background Indoor Air Concentrations of
Volatile Organic Compounds in North American Residences: A Compilation and Implications
for Vapor Intrusion (U.S. EPA, 2011) presents an evaluation of measured background VOC
levels in published indoor air studies.

The conceptual scenarios simulated in this document illustrate that many factors influence the
distribution of contaminant concentrations in soil gas  and suggest that selecting soil gas sampling
locations is a site-specific decision that should be supported by characterization of the extent,
location, and concentration of the source, as well as site geology, biodegradation, building
conditions, and other site-specific factors that can influence the distribution of VOCs in the soil
gas.

1.5    Document Development and Peer Review

This document was developed by EPA's Office of Solid Waste and Emergency Response
(OSWER). This document has undergone extensive internal agency review and has been
subjected to EPA's external peer review process. Details on the review stages and process may
be found in Appendix C to this document.

1.6    Document Organization

This technical document provides a series of simulations showing how different building and
subsurface conditions might influence vapor migration and VOC concentrations  in soil gas and
indoor air as VOCs move from a source into indoor air. The document is divided into sections
that include basic discussions of subsurface vapor sources (Section 2) and vapor migration
processes (Section 3). The remaining simulation results are organized according to the
conditions and processes they illustrate:

    •  Section 4: Factors Affecting Vapor Migration and Indoor Air Concentrations of
       Recalcitrant VOCs

    •  Section 5: Factors Affecting Vapor Migration and Indoor Air Concentrations of
       Biodegradable VOCs

    •  Section 6: Temporal and Spatial Variability in Subsurface and Indoor Air
       Concentrations.

Section 7 provides example scenarios illustrating that soil gas concentrations at exterior
locations may be similar to or different from sub-slab  concentrations. Section 8 summarizes the
results of the simulations presented in this technical document, and Section 9 provides the
references cited.

At the beginning of each section or subsection, text boxes are provided to guide the reader
through the simulations and results and help identify scenarios of interest.

Appendices A and B provide the model equations and the model inputs and assumptions,
respectively. Appendix C  describes the development  of this document and the peer-review

-------
February 24, 2012                      Conceptual Model Scenarios of the Vapor Intrusion Pathway


process. Appendix D contains the Variables Index, which lists the major variables in each
simulation, grouped into source conditions, subsurface conditions, and building characteristics,
to help the reader identify scenarios of interest.

As discussed in Section 1.4, the homogeneous subsurface scenario was selected as a baseline to
introduce the simplest case first, before incorporating the complexities of layered and
heterogeneous soils. Therefore, in each section of this technical document, the factors affecting
vapor migration and indoor air concentrations are presented first for homogeneous soils with
single or multiple buildings; then the effects of complexities in subsurface conditions are
gradually introduced with layered and heterogeneous soils for single- and multiple-building
scenarios. The factors discussed in Section 4 for recalcitrant chemicals are also discussed in
Section 5 for aerobically biodegradable petroleum  hydrocarbons to illustrate effects of
biodegradation on the distribution of VOCs in subsurface soil and indoor air.

-------
February 24, 2012                      Conceptual Model Scenarios of the Vapor Intrusion Pathway


2.0   Sources of Contaminated Vapors in the Subsurface
  This chapter includes a discussion on how sources are defined for the purposes of the simulations and a basic
  discussion of the transport and distribution of VOCs as they move from the source. There are no simulations in
  this chapter.
Many factors or activities may create a vapor source in the subsurface, including leaking gas
pipes, leaking underground storage tanks, aboveground spills, aboveground facilities that use
VOCs during operations, historical subsurface disposal of industrial wastes, and landfills.
Groundwater flowing through these primary source zones can be impacted and migrate away and
in turn be a source of contaminant vapors downgradient of the primary release area. In the
context of the vapor intrusion pathway, a source of contaminated vapors may be defined as the
presence of chemicals of sufficient volatility (and toxicity) that they are likely to volatilize under
normal temperature and pressure conditions and migrate through the porous media in the soil
matrix and into indoor air and present a potential risk to human health. Such sources may exist in
the form of contaminated soil gas and pore water in the unsaturated zone, residual or mobile non-
aqueous phase liquids (NAPLs) in the subsurface soil or on top of the groundwater table, or
dissolved-phase contaminants in groundwater. NAPL sources can be of particular concern
because they typically create higher unsaturated zone vapor concentrations and mass flux than
those above  dissolved groundwater plumes of the same chemicals. Most of the simulations in
this technical document assume a vapor source in soil gas above the groundwater table; the
vapors may originate from either dissolved VOCs in groundwater at the top of the capillary
fringe or NAPL sources on top of the water table. A few simulations (e.g., Figures 3 and 18)
address the presence  of vapor sources in the vadose zone, above the groundwater table, which
could be either lighter-than-water NAPL or denser-than-water NAPL trapped in pore spaces.

The capillary fringe is a zone immediately above the water table that acts like a sponge sucking
water up from the underlying groundwater. At the base of the capillary fringe, most of the soil
pores are completely filled with water. Above this zone, water content decreases with increasing
distance above the water table. The grain size of the soil particles influences the height of the
capillary fringe: fine-grained soils exert greater suction on the groundwater table, resulting in a
thicker capillary fringe that may be irregular across the upper surface, while  coarse-grained soils
exert less suction, resulting in a thinner capillary fringe that tends to be flatter along the top. The
capillary fringe may reduce the emission of vapors from a dissolved groundwater source because
its elevated water content limits the vapor migration (VOCs migrate much more slowly through
water than through air). In the case of a NAPL source floating above the water table, the
capillary fringe may also contain residual NAPL, and as a result, the emissions of vapors are less
restricted by the capillary fringe.

If the vapor source is in the vadose zone, the vapors migrate radially in all directions from the
source (i.e., upward toward the atmosphere, laterally outward, and downward toward the water
table, which may eventually lead to groundwater contamination). For all source types, soil vapor
concentrations decrease as distance from the source increases. If soil vapor monitoring data at a
given site are not consistent with this trend, there may be multiple VOC sources, such as NAPL
source(s) in the vadose zone  and a dissolved groundwater source.

-------
February 24, 2012                      Conceptual Model Scenarios of the Vapor Intrusion Pathway


Soil sources can be small and groundwater sources can be long and narrow due to site
hydrogeology; nevertheless, the soil gas plume associated with such sources can be large. When
interpreting the nature and extent of soil gas contamination, it is important to discern the origins
of VOCs in soil gas. The potential presence of multiple sources and the sparseness of
groundwater data at sites usually make this process difficult (Rivett, 1995).

VOCs in a vapor source may be classified by their potential for degradation during vapor
transport:

    •   Recalcitrant chemicals have a slow rate of biodegradation in natural aerobic settings.
       These chemicals tend to persist in the environment for a long time. In this document,
       recalcitrant chemicals are assumed to represent the chlorinated solvents, such as
       tetrachloroethene (PCE)  and trichloroethene (TCE).

    •   Aerobically biodegradable chemicals readily degrade in the presence of oxygen due to
       microbiological processes. Many of the petroleum hydrocarbons and methane fall in this
       category.

A VOC's potential for degradation during vapor migration will influence its vapor distribution in
the  subsurface and consequently its potential for vapor intrusion into buildings. Sections 3 and 4
discuss vapor intrusion processes and variables assuming that the chemicals are recalcitrant.
Section 5 shows the effect of aerobic biodegradation on vapor intrusion processes and variables.
Other types of chemical degradation are not addressed in  this document, including anaerobic
degradation, hydrolysis, and catalyzed reduction reactions. Some chemicals, such as the
chlorinated solvents, may produce more toxic compounds when they undergo degradation (e.g.,
PCE and TCE may produce vinyl chloride through anaerobic degradation). Production of such
toxic degradation products is not addressed in this document but should be considered in a site-
specific investigation.
                                           10

-------
February 24, 2012                       Conceptual Model Scenarios of the Vapor Intrusion Pathway


3.0   Vapor Transport and Fate in the Subsurface
  The simulations in this chapter address the role of diffusion and advection in shaping the migration and
  distribution of VOC vapors in subsurface soils and in indoor air. The VOC distributions are depicted as
  "normalized" values (i.e., the values are the vapor concentration at a given location divided by the source vapor
  concentration) rather than as absolute values. The use of normalized values makes it easier to envision the VOC
  distribution and its applicability to any source concentration.
  In this chapter, the VOCs depicted in the simulations are "recalcitrant," that is, they are not subject to aerobic
  biodegradation. Depictions that include aerobic biodegradation are covered in Section 5.
Vapor transport in the subsurface may be controlled by four primary processes:

    •  Diffusion occurs when there are spatial differences in VOC concentrations in the
       subsurface; vapors diffuse in the direction of lower concentrations.

    •  Advection occurs when there is bulk movement of soil gas induced by spatial  differences
       in soil gas pressure.

    •  Phase partitioning refers to the processes leading to VOC distribution between the soil
       gas, the dissolved phase in soil pore water, and the sorbed phase on soil particle surfaces.
       Phase partitioning will retard contaminant vapor transport in the subsurface under
       transient conditions, but not under steady-state transport conditions, when the mass
       transfer between phases approaches equilibrium.

    •  Degradation is usually associated with biodegradation, in which VOCs are converted to
       other chemicals by microorganisms in the subsurface.

Vapor transport may occur under transient or steady-state conditions. Under transient  conditions,
concentrations are changing with time. Under steady-state conditions, concentrations and
pressures are constant with time, although they may vary spatially. For example, if the conditions
are at steady state, the source concentration is constant with time (it does not increase  or
decrease), the VOC concentration distribution is fully developed, and the concentration in each
location is constant with time; also, all contaminant fluxes and emission rates are constant with
time. For steady-state transport conditions, the parameters that influence the transport by
diffusion and advection are soil porosity and moisture content, chemical diffusion coefficients in
air and water, soil  gas permeability, and building pressurization.  The Henry's law constant
(which quantifies chemical partitioning between air and water) may also influence transport
when moisture content is high and Henry's law constant is very low. For transient transport
conditions, VOC transport may also be influenced by phase transfer to the aqueous and solid
phases, which depend on the VOC-specific Henry's law constant and sorption coefficient to soil
organic carbon (Koc), and on the mass fraction of organic carbon in soil (foe).

Most simulations presented in this technical document represent steady-state transport
conditions; only a few transient transport scenarios are illustrated and discussed. Because the 3-D
Abreu and Johnson model is a transient solution of the transport equations, the steady-state
scenarios presented in this document were  obtained by running the model long enough to achieve
essentially steady-state conditions.
                                             11

-------
February 24, 2012                        Conceptual Model Scenarios of the Vapor Intrusion Pathway


This section discusses the mechanisms of diffusion and advection under steady-state conditions
with no degradation. Biodegradation is introduced in Section 5, and the effect of transient state
conditions is introduced in Section 6.

3.1    Diffusive Transport of Vapors in the Unsaturated Zone
  The objective of this section is to introduce the general concept of diffusion and the direction of vapor migration
  for different source locations. This section shows how recalcitrant contaminants migrate by diffusion through
  homogeneous soils from a source that is either at the groundwater table (Figure 2) or at the unsaturated soil
  zone (Figure 3). The contaminant vapor distribution reflects the location and geometry of the vapor source
  "footprint." To clearly show how concentration changes away from the source, the sources are limited in size and
  laterally separated from the building.
Vapor transport (or migration) by diffusion occurs when VOC concentrations vary spatially:
vapors migrate from an area of higher concentration (the source) to an area of lower
concentration (the surrounding area), as illustrated by the arrows in Figure 2 (groundwater
source) and in Figure 3 (vadose zone source). In the subsurface away from a building, the
dominant process for vapor transport is typically diffusion, but in the subsurface near a building,
both diffusion and advection processes may be important, as discussed in Section 3.2. Diffusion
occurs through the  soil gas and water present in the soil pores. Air (vapor-phase) diffusion
coefficients are about 10,000 times greater than water diffusion coefficients, so vapor diffusion
through the air-filled pores of the soil matrix is usually the dominant diffusion transport
mechanism for VOCs in the unsaturated zone, except in cases of high moisture content and very
low Henry's law constant. Consequently, for similar concentration gradients, as soil moisture
content increases, the vapor  diffusion rate decreases.
                                              12

-------
February 24, 2012
                                  Conceptual Model Scenarios of the Vapor Intrusion Pathway
   (/)


  "5.
  Q
      -2-
-4-
      -6-
      -8-
      70-
60-


50-


40-
      20-


      10-
                                    Vertical Cross-Section View
                      .y
              water tble
                                        Plan View at 2 m bgs
                                                            0.2
                                                          i \
                     %

                                      t
                10
                   20
30
40
50
60
70
80
90
100
                    Building footprint

        '  ~ ~ ~ \   Vapor source zone footprint
                                                x(m)
                                                                  ->•  Vapor migration
Figure 2. Direction of the vapor migration (due to diffusion) and resulting soil vapor concentration
           distribution for a groundwater vapor source (or NAPL at groundwater level).
          The soil vapor concentration contour lines are normalized by the source vapor concentration.
                                              13

-------
February 24, 2012
                Conceptual Model Scenarios of the Vapor Intrusion Pathway
                                     Vertical Cross-Section View
     -8
    70


    60


    50


    40


    30


    20


    10
                                        Plan View at 2 m bgs
   \v
                                                        0,01
               10
20
30
40
                   Building footprint
50       60
x(m)
70      80       90      100


        * Vapor migration
        	j   Vapor source zone footprint
  Figure 3. Direction of vapor migration (due to diffusion) and resulting soil vapor concentration
                   distribution for a source in unsaturated soil (vadose zone).
          The soil vapor concentration contour lines are normalized by the source vapor concentration.
                                              14

-------
February 24, 2012                       Conceptual Model Scenarios of the Vapor Intrusion Pathway
3.2    Advective Transport of Vapors Near Building Foundations
  The figures in this section illustrate how the pressure difference between a building and the underlying soil
  impacts advective flow (Figure 4) and VOC concentrations (Figure 5) under different foundation crack and
  building pressure conditions. The lower the indoor air pressure relative to the sub-slab soil gas pressure (i.e., the
  more under-pressurized a building is), the larger the soil gas flow rate into the building (QSOii) and the larger the
  concentrations of contaminants in the indoor air due to vapor intrusion, provided the soil type is permeable to soil
  gas flow. The plots in Figure 6 illustrate that when the soil gas flow rate into the building (QSOii) exceeds about 5
  to10 L/min, the rate of contaminant diffusion from the source to the sub-slab may limit the amount of
  contaminants available to flow into the building.
Advective soil gas transport occurs when soil gas containing VOCs moves due to spatial pressure
differences, which occur, for example, whenever there is a difference between the air pressure
within a building and the soil gas pressure. The air pressure within a building can be lower or
higher than the soil gas pressure, and even small pressure differences may cause advective flow
of gas into or out of the building through pores, cracks, or openings in the building floor or
basement walls. The pressure difference may be caused by temperature differences (i.e., the
"stack effect," when hot air inside the building rises), wind load on the building walls, the
operation of mechanical devices (e.g., exhaust fans,  air conditioners, heating units), or the
operation of combustion devices that vent exhaust gases to the outside (e.g., fireplaces, furnaces).

The pressure difference between a house-sized building and the surrounding soil is usually most
significant within 1 to 2 m of the structure, but measurable effects have been reported up to 5 m
from the structure (Nazaroff et al., 1987). Temperature differences or unbalanced mechanical
ventilation are likely to induce a symmetrical pressure distribution in the subsurface, but the
wind load on a building adds an asymmetrical component to the pressure distribution in the
subsurface and thus to the distribution of contaminants in soil gas.

In this technical document, the building and  soil air  pressures are reported as gauge pressure,
which is defined as the pressure difference relative to atmospheric conditions. If the building's
absolute pressure is lower than the atmospheric pressure (pressure differential is a negative
number), the building is under-pressurized; if it is higher than the atmospheric pressure (pressure
differential is a positive number), the building is over-pressurized.

Examples of the predicted soil  gas pressure distribution around buildings, as well as the resultant
advective soil gas flow rates into the building (Qs), are presented in Figure 4 for two soil gas
entry points consisting of (1) a crack along the perimeter of the foundation slab  and (2) cracks at
the center of the floor slab. The cracks have the same total length and width; only the location of
the cracks is different. The pressure distribution is symmetrical to the center of the building
foundation because the subsurface is homogeneous and wind load was not included in these
simulations.

Soil gas flows perpendicularly to the pressure field contour lines illustrated  in Figure 4, and for
the case of perimeter cracks, the calculated pressure fields suggest that air primarily travels down
from the ground surface to the  foundation crack located along the  perimeter, with the flow lines
beneath the building extending to greater depths in areas where the depth to the water table is
greater. For the  center-of-foundation crack scenario, the calculated flow is primarily horizontal
beneath the foundation, and the uniformity of the flow increases as the depth to groundwater
                                             15

-------
February 24, 2012
Conceptual Model Scenarios of the Vapor Intrusion Pathway
                    Crack at Perimeter of Slab                  Crack at Center of Slab

                                           Water Table 3 m bgs
                                            Water Table 8 m bgs
                                           Water Table 12m bgs
                                                                              10    12
    Figure 4. Change in pressure field distribution and soil gas flow rate (Qs) due to slab crack
                                position and groundwater depth.
 The soil gas gauge pressure contour lines are normalized by indoor air gauge pressure (5 Pa, under-pressurization).
                              The arrows indicate soil gas flow direction.
                                          (Abreu, 2005)
                                               16

-------
February 24, 2012                      Conceptual Model Scenarios of the Vapor Intrusion Pathway


decreases. The predicted soil gas flow rates are relatively insensitive to water table depth when
the depth is greater than 5 m bgs.

It should be noted that the simulations presented in Figure 4 represent homogeneous, sandy soils.
Under the homogeneous conditions simulated, the flow to a perimeter crack is larger than the
flow to a center-of-foundation crack because of the shorter flow path length from ground surface
to a perimeter crack. Heterogeneities in the subsurface at real sites will affect the pressure
gradient field and result in spatially more complex flow rates and patterns than those shown in
Figure 4.

In scenarios with coarser soils (sands and gravels), the soil  gas permeability is high,  and changes
in building pressurization may affect the air flow field and the resultant soil vapor concentration
profiles near buildings, as illustrated in Figure 5 for two soil gas entry points consisting of
cracks at the perimeter and at the center of the foundation slab. These simulations  assume a
homogeneous subsurface (sand) and no wind load, resulting in a symmetrical soil  gas
distribution beneath the  building foundation.  Figure 5 shows that under-pressurized buildings
may have higher soil vapor concentrations beneath the foundation when compared with over-
pressurized buildings where clean indoor air (i.e., no indoor VOC sources) flows outward to the
soil through the foundation cracks and dilutes soil vapor concentrations in the region around the
crack and, to some extent, beneath the slab. The profiles in Figure 5 also illustrate spatial
variability in sub-slab  soil vapor concentration  distribution. Although not presented in Figure 5,
scenarios with a building at atmospheric conditions (i.e., not pressurized) could still  exhibit some
concentration buildup below the foundation due to the capping effect of the concrete slab.

In scenarios with fine-grained soils (silts and clays), the soil gas permeability is low. Therefore,
in these scenarios,  building pressurization may not affect the soil vapor concentration profile
because the airflow field and soil gas flow rates (Qs) may be negligible. Nevertheless, over-
pressurization of the building can reduce the indoor air concentration by driving the  soil gas flow
direction from the building to the soil, as presented in Figure 6 and discussed below.

The soil gas flow rate into and out of a building also affects the indoor air concentration. Figure
6 shows the influence  of soil gas flow rate  (Qs) on normalized indoor air concentration (a)
predicted by the model for basement and slab-on-grade foundations with full-length  perimeter
cracks and a homogeneous subsurface for a range of soil properties that represent gravel, sand,
silt, and clays (Abreu and Johnson, 2005, Table 2). The results in Figure 6 suggest that the
normalized indoor air concentrations (a) decrease rapidly for lower soil gas flow rates (e.g., less
than 1 L/min) and are relatively constant for higher soil gas flow rates (e.g., greater than 5
L/min), because at those higher rates, the VOC transport into the building becomes limited by
the rate at which VOC mass diffuses from the source to the soil below the building. Figure 6 also
illustrates the effect that building pressurization may have in reducing vapor intrusion, as shown
by the reductions in the normalized indoor air concentrations for negative soil gas flow rates (Qs)
corresponding to building over-pressurization.
                                            17

-------
February 24, 2012
                         Conceptual Model Scenarios of the Vapor Intrusion Pathway
                   Crack at Perimeter of Slab                   Crack at Center of Slab
                                    Building Underpressurized by 20 Pa
                                    Building Underpressurized by 5 Pa
         a -s F'   iapi
         _Q
                                    Building Overpressurized by 5 Pa
            -2-
            -4-
            -6-
                 Qs = -4 L/min \
                                          0.1
QJ7

0.8
                   1   vapor source
      I
i
                                       Qs = -2 L/min
                                                                             -04-
                                                              0.4
                                                                            07
                                            ~     ^        0.9
                                             vapor source      1
n

4-
6-
0
^^
Qs = -16 L/min \
0.2 ^-P-
-03^
Building Overpressurized by 20 Pa


/
/ / ^^^^
1^
^^^^^^^^H
— -" ' ,^^ ^^,~~-~ ~~~~
-OS 	 ~~ __— -" „--' ^- — 1

0.9 ,
1 vac
— -^^_— —
— — ^^^^^
or source ^

-


—
h" v / y
0.01 O./ O/
^x / / /^^^^~~~
— "'" „-/ / ,/ ./^^ ,-—~~~~~ — "~
^_______^-^^^ ^^^ ^~^ ^~^~~^ 	 	
~~~~~^^--— ~~~~^^ -~~~~~^ -~-~~~^~~
— — — ^-^^^^^^^^ ^M — B~"
	 	 	 — 	 ___^_^^^
vapor source 1 w
                           10    12  0
                                  x(m)
                                                                                   10    12
       Figure 5. Soil vapor concentration distribution influenced by building pressurization
                                      and slab crack position.
      The soil vapor concentration contour lines are normalized by the source vapor concentration at 8 m bgs.
    Positive values of the soil gas flow rate (Qs) reflect gas flow into the building, and negative values reflect flow
                                          out of the building.
                                                 18

-------
February 24, 2012
                    Conceptual Model Scenarios of the Vapor Intrusion Pathway
         1.E-01
         1.E-03 ,
         1.E-05 ,
     a  1.E-07
         1.E-09 ,
         1.E-11
         1.E-13
                                    X
                                                 X
 A

X

o
O Source 18m bgs (slab-on-grade)

XSource 3 m bgs (slab-on-grade)

A Source 18m bgs (basement)

• Source 8 m bgs (basement)

D Source 3 m bgs (basement)
                                                No data for source 8 m bgs (slab-on-grade)
                                    10     15     20     25
                                              Qs (L/min)
                                            30
                    35
40
45
 Figure 6. Relationship between normalized indoor air concentration (a) and soil gas flow rate (Qs)
                                  into or out of the building.
               Positive values of Qs reflect soil gas flow from the subsurface into the building;
                   negative values reflect flow out of the building and into the subsurface.
                                   (Abreu and Johnson, 2005)

The simulations presented in this technical document account for pressure-driven advective flow
near the foundation, but no density-driven advective flow in soil gas in the subsurface
environment. Although density-driven advective flow of soil gas has been discussed in the
literature (e.g., Falta et al., 1989; Mendoza and Frind, 1990; Johnson et al., 1992; Hughes et al.,
1996), only in extremely high permeability materials could density-driven advection occur, and it
would be limited to the close proximity of a NAPL source in the unsaturated zone (Johnson et
al., 1992; Hughes et al., 1996). This extreme scenario (for density-driven advective flow in soil
gas in the subsurface environment) was not simulated here, because this document focuses on
more  typical scenarios, where diffusion is the dominant transport mechanism for VOCs in the
unsaturated zone away from the building, as discussed in  Section 3.1.
                                             19

-------
February 24, 2012                       Conceptual Model Scenarios of the Vapor Intrusion Pathway
                             [This page intentionally left blank.]
                                             20

-------
February 24, 2012                      Conceptual Model Scenarios of the Vapor Intrusion Pathway
4.0   Factors Affecting Vapor Migration and Indoor Air Concentrations
       of Recalcitrant VOCs
  The simulations in this chapter cover a broad range of factors (source concentration and location, subsurface
  characteristics, building conditions) that can affect the migration and distribution of VOC vapors in subsurface
  soils and in indoor air. In this chapter, the VOCs depicted in the simulations are recalcitrant and not subject to
  aerobic biodegradation. Depictions that include aerobic biodegradation are covered in Section 5. The simulations
  in Section 4 are applicable to chlorinated hydrocarbons.
Several factors may affect subsurface vapor migration and the indoor air concentration due to
vapor intrusion into buildings. Although the main factors discussed in this section can affect both
recalcitrant and biodegradable contaminants, this section focuses on the behavior of recalcitrant
contaminants. In this document, recalcitrant compounds are assumed to represent the
contaminants that do not readily biodegrade in the subsurface under natural aerobic conditions
(e.g., chlorinated hydrocarbons). The additional factors and responses unique to biodegradable
contaminants are discussed in Section 5.0. The factors discussed here include the following:

    •  Source concentration (Section 4.1)

    •  Source depth and lateral distance from a building (Section 4.2)

    •  Other factors in scenarios with a homogeneous subsurface, including multiple buildings,
       permeable fill and building pressurization, building conditions, and multiple sources
       (Section 4.3)

    •  Subsurface heterogeneities, including soil moisture distribution and ground cover
       (Section 4.4)

The simulations presented below show the effect of varying one variable at a time (e.g., source
depth) while the other variables (e.g., building pressurization, air exchange rate) are held
constant at the baseline values (described in Appendix B), unless otherwise specified in the text
and figures.  The results and discussions in each subsection are specifically related to the
conditions simulated and are intended to show general trends and provide a basic understanding
of expected  soil vapor concentration profiles and indoor air concentration for the conditions
simulated.

Many simulations in this technical document were performed for the baseline homogeneous
subsurface condition, which assumes sandy soils with a pore water saturation of 20% of the total
pore space. The predicted normalized indoor air concentrations for those simulations are
representative of relatively dry, high-permeability soil conditions. For soils typically having a
higher moisture content (e.g., silt, clay), which results in less vapor migration by diffusion and
advection, less vapor intrusion is expected to occur (and the normalized indoor air concentrations
are expected to be smaller).
                                            21

-------
February 24, 2012                       Conceptual Model Scenarios of the Vapor Intrusion Pathway


4.1    Source Concentration
  The figures in this section illustrate the relationship between the source vapor concentration (1,000 and 100,000
  ug/m3) and the concentration of VOCs in the soil gas and indoor air for basement and slab-on-grade foundation
  types (Figure 7a). Because concentrations are primary variable in these scenarios, the results are illustrated both
  in absolute and normalized concentrations. These simulations illustrate how the foundation slab inhibits upward
  diffusion when compared with the open surface areas beside the buildings so that the VOC concentrations
  beneath a building are higher than they are at an  equivalent depth beside it (if the soil is homogeneous and the
  source is under the building). Figure 7b depicts the same scenarios that are depicted in Figure 7 a but presents
  the VOC distributions as "normalized" values.
For recalcitrant VOCs the effect of the source concentration on vapor migration and indoor air
concentration due to vapor intrusion is illustrated in Figures 7 a and 7b. Figure 7a presents the
soil vapor concentration profiles and the indoor air concentrations in units of ug/m3. Figure 7b is
a normalized version of Figure 7a, where the soil vapor concentration profile and the indoor air
concentration are normalized (divided) by the source vapor concentration. These figures present
two vapor source strengths, 1,000 and 100,000 ug/m3, and two building foundation types,
basement and slab-on-grade. The source is located beneath the building at a depth of 8 m bgs,
which is 6 m below the foundation slab for the basement scenario and about 8 m below the
foundation for the slab-on-grade scenario.

As illustrated in Figure 7a, the higher source concentrations result in higher concentrations in the
subsurface gas and in the indoor air (if there is a vapor intrusion pathway). Figure 7b shows that,
for recalcitrant chemicals, normalized soil vapor concentration distributions and normalized
indoor air concentrations (a) are independent of the source vapor concentration (when all other
factors are held constant).

The chemical concentration is higher beneath the foundation slab compared with concentrations
at similar depths away from the building. This  effect is common for all simulations in which the
soil is homogeneous and the source is under the building. This effect is more pronounced for
basement foundations than for slab-on-grade foundations because of the shorter distance between
a basement foundation and the source and because the soil beneath a basement foundation is
further from the surface. In the open surface areas far from the building, transport is dominated
by diffusion, and the vertical concentration distribution changes linearly with upward distance
from the source and is the same for both basement and slab-on-grade constructions.
                                             22

-------
February 24, 2012
Conceptual Model Scenarios of the Vapor Intrusion Pathway
f)
-2-
4
-6-
£
D) 8
tL
0)
Q
o-
-2-
.4
-6-
Q
Basement

r^E3^--
=^ """
— J \


-<£oo
\^ \
^v X
\\^
in — \.t. uy/in
-^ (oc = 1.2E-3)
100
200
____300_
400
_5QO
-^gpo
^~~~~~~^____^_
ann

1,000 vapor source w
iii
Source Vapor Cone = 1 ,000 ug/m3

ER
=^~
f— ^ ^^
^0,000
\
^x \
^^~-,
80,000
90,000
\n= izu ug/m
-"" (a-1.2E-3)
10,000
20,000
30,000
^^o.ooo^
-^50,000
--60000^
^--____ 	
— - — —________^

100,000 vapor source w



-

-
Slab-on-grade
— I ^ I A - 0 R1 unlrr?
\ (a = 6.1E-4)
100
^2QQ_
500 _300_
^400
Rnn

700
800

900
1,000 vapor source w
iii
Source Vapor Cone = 1 ,000 ug/m3

/, IM — D i ug/rn
\ (oc = 6.1E-4)
10,000
-50,000 20,000
\. \ \^
___30,000
60,000 ^40,000^

70,000
80 000

90,000
100,000 vapor source w
0 1 1 1 1 1 1 1 1 1 1 '
0 2 4 6 8 10 12 0 2 4 6 8101
             Source Vapor Cone = 100,000 ug/m
                 Source Vapor Cone = 100,000 ug/m
                                                 x(m)
Figure 7a. Effect of source vapor concentration and foundation type on soil vapor distribution and
                                    indoor air concentration.
 Soil vapor concentration contour lines are in units of |ig/m3. IA is the indoor air concentration in units of |ig/m3 and a
           is the normalized indoor air concentration (dimensionless). The source is located at 8 m bgs.
                                               23

-------
February 24, 2012
Conceptual Model Scenarios of the Vapor Intrusion Pathway
                        Basement
                         Slab-on-grade
£
§
tL
Q
                                                                     a = 6.1E-4
                                                                     (IA = 0.61 ug/m3)
                                                                     -—-____ o
                                                                0.3  ^7
                                                     0.6
                                                     0.8
                                                    0.9
              Source Vapor Cone = 1,000 ug/m
                 Source Vapor Cone = 1,000 ug/m
                                                                                  10     12
             Source Vapor Cone = 100,000 ug/m
                                               x(m)
                Source Vapor Cone = 100,000 ug/m
   Figure 7b. Soil vapor concentration distribution and indoor air concentration from Figure 7a
 presented as normalized values (i.e., the absolute values in Figure 7a were divided by the source
                                   vapor concentration).
                                 The source is located at 8 m bgs.
                                            24

-------
February 24, 2012                       Conceptual Model Scenarios of the Vapor Intrusion Pathway
4.2    Source Depth and Lateral Distance from Building
  The figures in this section illustrate how the depth and location of the source influence soil vapor and indoor air
  contaminant concentrations. In settings with homogeneous soils and a vapor source at the groundwater table
  directly beneath the building, the soil gas and indoor air concentrations of VOCs are inversely related to the
  distance between the source and the building (Figure 8 and Figure 10).  In settings where the vapor source at the
  groundwater table is not directly under the base of the building (i.e., it is laterally offset from it), the indoor air
  concentrations increase with the source depth as a result of greater lateral diffusion from the source (Figure 9).
  Figure 11  is a plot that depicts how those relationships vary depending on the groundwater vapor source depth
  and its lateral separation from the building. Figure 12 illustrates how lateral diffusion can create similar
  normalized indoor air concentrations for two sources at different depths but at similar lateral distances from the
  building: one source is at a shallow unsaturated soil zone, and the other source is at a deeper groundwater table.
The effect of source depth on the soil vapor concentration distribution of recalcitrant chemicals is
illustrated in Figure 8. The figure presents normalized soil vapor concentration profiles for a
uniform groundwater vapor source located beneath the building at three different depths (3, 8,
and 18m bgs) and for two building foundation types (basement and slab-on-grade). The source
depth measured from the building foundation is 1, 6, and 16m for the basement scenario and
approximately 3, 8, and 18m for the slab-on-grade scenario.

For the shallowest source (3 m bgs), the concentration below the foundation is about 90% of the
source concentration for the basement scenario and about 30-80% of the source concentration
for the slab-on-grade scenario. For a deep source located 18m bgs, the predicted concentration
below the foundation is about 20-30% of the source concentration for the basement scenario and
about 10-20% of the source concentration for the slab-on-grade scenario. The normalized indoor
air concentrations (a) presented in Figure 8 show that as the  source depth increases by a factor of
six, the normalized indoor air concentration decreases by a factor of three. For the  basement
scenario,  the normalized indoor air concentrations are similar as the source depth increases from
3 to 8 m bgs because the increased soil gas flow beneath the  building predicted for the water
table at 8  m bgs offsets the difference in near-crack soil gas concentrations. The normalized
indoor air concentrations of comparable basement and slab-on-grade scenarios differ by at most
about a factor of two; the difference is due to the larger source-slab separation and air flow
pathway in the slab-on-grade scenario.
                                              25

-------
February 24, 2012
                      Conceptual Model Scenarios of the Vapor Intrusion Pathway
                              Basement                            Slab-on-grade
                                             Vapor Source 3 m bgs
                                  a=1.7E-3
                                  Qs = 3.1 L/min
                                                  a=1.2E-3
                                                  Qs = 4.9 L/min
0-

-2-
-4-
-6-
£
w

^_^^ Vapor So
a - \ IV T.
|— |— 1
^
^ 	 1
'""""""""""""<""$
^7 oV
\v \,
_£L8_
0.9
1 vapor sourc
Qs = 4.0 L/min
0.1
0.2
— O3__
05 °-i-

^~-~_____
"~~~~______

e
i i i i i

_
urce 8 m bgs
••=ll=:=lll= 	 ^
— i ^ a- 6 IE 4
5 Qs = 5.1 L/min
0.1
°-5 04'^3^JI2—

06

0.7

.0
0.9 _
	 r^ 	 1 	 1 	 1 	 1 — —
             a.
             (D
             Q
                -2
                -4-
                -6-


                -8-


               -10-


               -12-
                        Vapor SoujrcejIS^m bgs

               a=5.7E-4
               Qs = 4.1 L/min
                                      0.1
                    0.4
0.5
 0.7
               .14-   0.8
               -1


               -18
                      '.9
                 0
                                                                      a = 2.8E-4
                                                                      Qs = 5.1 L/min
                                                               \0.2
                                                        0.4
                                   0.5
                                   0.6
                                                        0.7
                                                        0.8
                                                        0.9
I      I     I      II
2     4     6     8    10   12  0
                                                          2    4     6
                                                           10   12
                                                  x(m)
 Figure 8. Effect of groundwater source depth on soil vapor distribution and normalized indoor air
                            concentration (a) for two foundation types.
 The soil vapor concentration contour lines are normalized by the source vapor concentration. Qs is the soil gas flow
                           rate predicted for building under-pressurized by 5 Pa.
                                            (Abreu, 2005)
                                                26

-------
February 24, 2012
                Conceptual Model Scenarios of the Vapor Intrusion Pathway
As discussed previously, for a source located at the water table, vapors migrate upward and
laterally outward from the source. Figure 9 presents predicted normalized soil vapor
concentration distributions and normalized indoor air concentrations for a vapor source located at
a lateral distance from a building with a basement. This figure illustrates the upward and lateral
vapor migration for a vapor source of recalcitrant chemicals at groundwater level in a
homogeneous subsurface.  If the groundwater is shallow and the ground surface is open to the
atmosphere, vapor migration is predominantly upwards toward the atmosphere and lateral
migration is less significant. If the groundwater is deeper, lateral vapor migration becomes more
significant compared with upward migration. In the conceptual site scenarios represented in
Figure 9, the normalized indoor air concentration for the scenario with deep groundwater is three
orders of magnitude greater than the value with shallow groundwater; therefore, under the
simulated conditions, vapor intrusion may be of greater potential concern if a laterally displaced
source is deeper rather than shallower for recalcitrant compounds.
                                                    Shallow Groundwater Source
                 Qs = 3.3 L/min
                  a = 4.2E-8
 O)
 _Q
    -3-
              10
 i
20
                         0.01  /IT         '^B*
                                           1E-3
                                1E-5    1E-4I
30
40
  I
 50
x(m)
 source
70~  ~~80
                                                      Deep Groundwater Source
    -8
                                                                                       100
  Figure 9. Soil vapor distribution and normalized indoor air concentration (a) for a spatially finite
           vapor source laterally separated from building at two groundwater depths.
 The soil vapor concentration contour lines are normalized by the source vapor concentration. Qs is the soil gas flow
                         rate predicted for building under-pressurized by 5 Pa.
                                        (Abreu, 2005)
                                            27

-------
February 24, 2012
Conceptual Model Scenarios of the Vapor Intrusion Pathway
If the vapor source is underneath the building, as illustrated in Figure 10, the normalized indoor
air concentration decreases with increasing source depth, with a difference between the
normalized indoor air concentrations of the shallow source (3 m bgs) and the deep source (8 m
bgs) of about 40%. Comparison of the normalized indoor air concentrations between Figures 9
and 10 illustrates the effect of source location on the contaminant indoor air concentrations (i.e.,
comparing a source below the building with a source at 20 m lateral distance  from the building,
with both sources at the same depth below ground surface). The difference between the
normalized indoor air concentrations for the source beneath the building and the source to the
side is about two orders of magnitude for the deep source and about five orders of magnitude for
the shallow  source with an open ground surface.
 O)
 .Q
 Q.

 Q
                                                          Shallow Groundwater Source
              10
       5.9
 jjjjiiillll
30      40
        50
       x(m)
60
70
80
90
100
                                                             Deep Groundwater Source
     -8
                                                                                       100
 Figure 10. Soil vapor distribution and normalized indoor air concentration (a) for a spatially finite
               vapor source directly under a building at two groundwater depths.
 The soil vapor concentration contour lines are normalized by the source vapor concentration. Qs is the soil gas flow
                         rate predicted for building under-pressurized by 5 Pa.
                                        (Abreu, 2005)
                                            28

-------
February 24, 2012
                    Conceptual Model Scenarios of the Vapor Intrusion Pathway
The relationship between the normalized indoor air concentration and the lateral separation
between the source and the building is plotted in Figure 11 (from Abreu and Johnson, 2006) for
the basement and slab-on-grade scenarios with the source at two groundwater depths (3 and 8 m
bgs). The results show that the dependence of indoor air concentrations on lateral distance
between the source and the building is more influenced by the source depth and less influenced
by the foundation type (basement, slab-on-grade). With increasing lateral distance from the
building, the normalized indoor air concentration decreases more rapidly for shallow sources
than for deeper ones. For laterally displaced sources, normalized indoor air concentrations are
higher for deeper sources than for shallow ones if the subsurface is homogeneous and open to the
atmosphere. These results are in general agreement with the work of Lowell and Eklund (2004).
       1.E-02 q
       1.E-03 !
       1.E-04
  a   1.E-05
       1.E-06 ,
       1.E-07 ,
       1.E-08
                                                   source zone no longer
                                                   beneath building
                     10 m x 10 m building footprint
                     source size 30 m x 30 m
—A—Source 3 m bgs (basement)

---A--- Source 3 m bgs (slab-on-grade)

—•—Source 8 m bgs (basement)

- -D - - Source 8 m bgs (slab-on-grade)
            -15      -10       -50         5        10       15
                             Source Edge to Building Center Separation (m)
                                                         20
25
   Figure 11. Relationship between source-building lateral separation distance and normalized
                                 indoor air concentration (a).
   The separation is measured from the edge of the source zone to the center of the building; negative values and
                 values <5 m indicate that the source is to some extent beneath the building.
     Basement and slab-on-grade scenarios. Source located at groundwater table at depths 3 m and 8 m bgs.
                                   (Abreu and Johnson, 2006)
                                             29

-------
February 24, 2012
Conceptual Model Scenarios of the Vapor Intrusion Pathway
The results and discussion presented in Figures 9 to 11 are specific to groundwater vapor sources
at the top of the capillary fringe and where there is homogeneous sandy soil; variations from
these assumptions will affect the results and conclusions. For example, Figure 12 shows the
predicted results for a scenario with a vapor source in the vadose zone and a scenario with a
vapor source located at groundwater level. Both sources are at a 20 m lateral distance from the
edge of a building, and the groundwater depth is 8 m bgs in both scenarios; the source located in
the vadose zone extends from 2 to 3 m bgs. The normalized indoor air concentrations calculated
for these scenarios are similar (1.3E-5 and 1.7E-5), although the source at the vadose zone is
shallower (2-3 m bgs). The vertical extension of the vadose zone source (1 m) and its distance to
the water table (5 m) allowed the vapors to migrate in all directions and not just preferentially
upwards. Other scenarios with a layered and heterogeneous subsurface are presented in Section
4.4

                              Vertical Cross-Section View
                                                                                    100
     O)
     .a
                                            a=1.7E-5  Qs = 4L/min
                                              a=1.3E-5 Qs = 4L/mm
         -8-
                                                                             90
                                              100
  Figure 12. Soil vapor distribution and normalized indoor air concentration (a) for two spatially
     finite source types (unsaturated soil and groundwater) laterally separated from building.
 The soil vapor concentration contour lines are normalized by the source vapor concentration. Qs is the soil gas flow
           rate predicted for building under-pressurized by 5 Pa. The groundwater table is at 8 m bgs.
                                             30

-------
February 24, 2012                      Conceptual Model Scenarios of the Vapor Intrusion Pathway
4.3    Other Conditions Simulated for Scenarios with Homogeneous Subsurface

This section presents soil vapor concentration profiles from a large vapor source of recalcitrant
VOCs that extends beneath two or more buildings and illustrates how a variety of building
variables, such as foundation condition or building pressurization, affect the distribution of soil
vapor concentration and the indoor air concentration. For many of these simulations, the soil
vapor concentration distribution is illustrated as one vertical cross-section through the center of
the building and horizontal plan views at two depths.

4.3.1  Multiple Buildings
  The figures in this section illustrate that the presence of multiple single-family residences at typical spacing and
  construction styles may have little or no effect on vapor intrusion when compared with a single-building scenario
  (compare Figure 13 through Figure 15 with Figure 7b). They also illustrate the potential capping effect of the
  foundation slab, resulting in higher concentrations below the building compared with the concentrations at similar
  depths at exterior locations.
The effect of multiple buildings on the soil vapor concentration distribution and the indoor air
concentration for homogeneous subsurface scenarios are illustrated in the next three figures. The
vapor source is located at a depth of 8 m bgs and extends beneath each building. Figure 13
shows two buildings with basements that are 10 m apart, Figure  14 shows two adjacent
buildings with basements, and Figure 15 shows two adjacent buildings, one with a basement and
one with a slab-on-grade foundation. The buildings are all under  the baseline conditions reported
in Appendix B (e.g., constant under-pressurization, air exchange rate, perimeter cracks).

Figures 13 through 15 illustrate that under homogeneous conditions and for under-pressurized
buildings, soil vapor concentrations are higher beneath the building footprints than at the same
depth in adjacent open areas. These figures show that the presence of multiple buildings has little
or no effect on the normalized indoor air concentration (a) for a single building (see Figure 10) if
the building conditions are the same, the subsurface is homogeneous, and the source vapor
concentration extends evenly beneath each building. The scenario in Figure 15 also illustrates the
effect of an impermeable surface adjacent to a building, with the  impermeable surface
represented by the slab-on-grade foundation slab of the second building. The vapor concentration
in the subsurface adjacent to the basement below the  impermeable surface is higher than the
concentration at a comparable depth below an  open-ground surface, which is consistent with
scenarios modeled by Pennell et al.  (2009). Other conceptual model scenarios are presented in
Section 4.4 to illustrate the effect if the subsurface is heterogeneous, as well as the effect of
natural or anthropogenic barriers to contaminant migration.
                                            31

-------
February 24, 2012
                           Conceptual Model Scenarios of the Vapor Intrusion Pathway
                                 Vertical Cross-Section View
               
-------
February 24, 2012
   Conceptual Model Scenarios of the Vapor Intrusion Pathway
                                Vertical Cross-Section View
      0
                                                    cc =  .-
                                                       = 3.4 L/min
     -8
/agor Source,

 Plan View at 2 m bgs
60
Kn
oU
/in
on
OU
9n
zu
10-
n
/ ^\ \
/ ^^^^~" ~~~~~~~~\ \ \

/ i

V \ ' v I /
\i _,/

\ // /

/ u
60


50

_, /in
I
>> ^n
OU
9n


10
n
^^ v r
— - — — - CN}1
^ /~ ^~--~~ —^ "^. \
/ /^^^ 	 ^^^Tix\ \
f, \ \^
\ \
02 0.5 ( d.6 °-5l 0.2
i i
/
aAVl:: 	 ^^^gf / '

^^001
\" ^^X ,/
        0       10     20     30     40      50      60
                                              x(m)
       I	n Vapor source zone footprint
                           70
80
90     100
 Figure 14. Soil vapor distribution and normalized indoor air concentration (a) for a scenario with
                      two identical adjacent buildings overlying a plume.
   The soil vapor concentration contour lines are normalized by the source vapor concentration. The source is at
             8 m bgs. Qs is the soil gas flow rate predicted for building under-pressurized by 5 Pa.
                                             33

-------
February 24, 2012
                                Conceptual Model Scenarios of the Vapor Intrusion Pathway
       0-
             a=1.2E-3
             Qs = 3.7 L/min
                          Vertical Cross-Section View
                                               = 6E-4
                                             Qs = 4.3 L/min
70
60
50
40
30
20
10
 0
                                      Plan View at 2 m bgs
           0.01
            \
                       1  '0
                                                                           \
                                                                          0.01
      70
      60
      50
      40
      30
      20
      10
       0
                                      Plan View at 5 m bgs
                                                                   0.01
                     .5
0.6
0.5 I
 J:
                                                              0\1
         0      10      20     30     40      50     60     70      80     90     100
                                             x(m)
         I	]  Vapor source zone footprint
 Figure 15. Soil vapor distribution and normalized indoor air concentration (a) for a scenario with
            two adjacent buildings with different foundation types overlying a plume.
   The soil vapor concentration contour lines are normalized by the source vapor concentration. The source is at
             8 m bgs. Qs is the soil gas flow rate predicted for building under-pressurized by 5 Pa.
                                            34

-------
February 24, 2012                       Conceptual Model Scenarios of the Vapor Intrusion Pathway


4.3.2  Permeable Fill and Building Pressurization
  Figure 16 compares building over-pressurization with building under-pressurization for two adjacent buildings
  with permeable backfill around the building foundations. With permeable sub-foundation conditions, over-
  pressurization leads to flow out of the building, lower subslab VOCs, and very low indoor air VOC concentrations,
  while under-pressurization leads to soil gas flow into the building and elevated subslab and indoor air VOCs.
A common construction practice is to backfill around and beneath a concrete foundation with
construction aggregate (various mixtures of gravel and sand). Granular fill may also exist along
utility conduits below the floor (e.g., floor drains, sanitary sewer lines, water mains). This can
create a region adjacent to the foundation slab and walls that is more permeable than the
surrounding native soils. To gain some insight on the possible effect of a more permeable region
adjacent to the foundation associated with building pressurization, a simulation was performed
assuming two adjacent buildings with a 50 cm thick permeable fill around the foundation slab
and walls. The fill was assumed  to have a soil gas permeability of 5E-11  m2 (coarse sand), a total
porosity of 0.5 (cm3voids/cm3soii),  and a moisture content of 0.01 (cm3water/cm3voids).2 The native
soil properties are for the baseline homogeneous sand presented in Appendix B, and the two
buildings are under baseline conditions, except that one building is assumed to be under-
pressurized by 2 Pa (gauge pressure) and the second  building is assumed to be over-pressurized
by 2 Pa.

The predicted normalized soil vapor concentration distribution, normalized indoor air
concentration (a), and soil gas flow rates (Qs) are presented in Figure 16. The predicted soil gas
flow rates in and out of the buildings are about +7 L/min and -7 L/min at pressurization of 2 Pa
and are higher than the soil gas flow rates predicted for buildings pressurized by 5 Pa without
permeable fill (see Figure 5). The normalized indoor air concentrations fall in the same range of
values found for the homogenous soil scenario with equivalent soil gas flow rates (see Figure 6).
The reduction in indoor air concentration for the over-pressurized building is due to the  air flow
from indoors to the subsurface. For under-pressurized buildings with a permeable fill, Pennell et
al. (2009) reported a similar increasing trend in soil gas flow rates, as well as a decrease in soil
gas concentrations immediately near the building foundation.

Figure 16 illustrates that the presence of a permeable fill may increase the dilution of the sub-
slab concentration if the air flow reverses direction in and out of the building (assuming that the
source of VOCs is in the soil gas and not inside the building). Research is still needed, however,
to determine to what extent the presence of granular  fill and utility conduits facilitate the flow of
air into the subsurface and ultimately, beneath the slab.
  Actual drainage layers may have different properties; these conditions were selected for modeling purposes to
  show the general effect of a layer that is relatively more permeable against the building foundation.
                                             35

-------
February 24, 2012
                             Conceptual Model Scenarios of the Vapor Intrusion Pathway
                   Structures with 50 cm of Permeable Backfill Around Foundation
                      Vertical Cross-Section View Through Center of Buildings
Overpressurized 2 Pa
      Qs = - 7 L/min
          ; = 1E-16
                                          n
   /Underpressurized 2 Pa
"^  Qs = + 7 L/min
     cc=1.3E-3
               Vertical Cross-Section View Through Crack on Perimeter of Buildings
               10
            20
30
   Sourc^
40      50
       x(m)
          60
70
80
90
100
    Figure 16. Soil vapor distribution for a scenario with two adjacent buildings under opposite
                          pressurization, and with permeable backfill.
   The soil vapor concentration contour lines are normalized by the source vapor concentration. The source is at
          8 m bgs. a is the normalized indoor air concentration and Qs is the predicted soil gas flow rate.
                                             36

-------
February 24, 2012                      Conceptual Model Scenarios of the Vapor Intrusion Pathway


4.3.3  Building Conditions
  Figure 17 illustrates that building conditions play a major role in determining the degree to which contaminated
  vapors enter a structure (building pressurization and the nature of foundation cracks) and the degree to which
  indoor air is mixed with and diluted by outdoor air (building air exchange rate and building size: volume). The
  depicted scenarios include a building that is perfectly sealed and buildings with a range of under-pressurizations
  and air exchange rates. The depictions also include differing source conditions.
Most of the simulations presented so far address the effect of subsurface factors and building
conditions assuming either one building at the site or the same set of conditions for each
building. However, subsurface conditions and the vapor concentration distribution beneath
buildings are not the only factors that determine the indoor air concentration due to vapor
intrusion. Indoor air concentration is also influenced by building conditions, which may vary
from building to building and may also vary seasonally (e.g., building air exchange rates may be
higher in summer than in winter; the stack effect may be greater in the winter). Therefore,
building conditions may explain some of the variability in indoor air concentrations found
between buildings at the same site and may also explain the variability in indoor air
concentration for the same building in different seasons (or at different times).

Variability of indoor air concentration between  buildings in similar settings may be the result of
variability in and interactions among the following building factors:

    •  Existence and extent of openings or cracks in the foundation

    •  Building pressurization and resultant soil gas flow rate (Qs) into (under-pressurized) or
       out of (over-pressurized) the building

    •  Building air exchange rate (AER), which is the number of times the indoor air is
       exchanged with outdoor atmospheric air over a specified period of time

    •  Building air flow rate (Qbdg), which is the rate at which the volume of contaminated
       indoor air is exchanged with outdoor atmospheric air; this volume is based on the height
       at which the contaminated indoor air is considered to be fully mixed.

For a given building, AER and Qbdg are not independent of each other, as  AER is defined to be
the Qbdg divided by the building volume; however, buildings of different size can have identical
AERs but different values of Qbdg.  In theory, the indoor air concentration  is inversely
proportional to  AER and Qbdg, with indoor air  concentration decreasing whenever AER and
Qbdg increase (assuming other conditions remain constant). Two buildings at the same site may
have the same sub-slab concentrations, the same AER values, but different Qbdg values because
of different indoor air volumes; therefore, their  normalized indoor air concentrations (a) may be
different,  as illustrated in the scenarios below.

Variations in the building pressurization and resulting Qs were discussed in previous sections
(Sections 3.2),  assuming that AER and Qbdg were constant.  This section presents simulations
that address the variability in AER and Qbdg between buildings, as well as the incomplete
pathway case (i.e., no soil gas entry points or cracks in the foundation). Figure 17 presents the
conceptual models, based on specific scenarios  and conditions simulated, and shows the
                                            37

-------
February 24, 2012                      Conceptual Model Scenarios of the Vapor Intrusion Pathway


predicted normalized soil vapor concentration distribution and indoor air concentrations for three
slab-on-grade buildings under several building conditions and source scenarios:

    •   Building A has no openings or cracks and the foundation is perfectly sealed; therefore,
       the vapor intrusion pathway for this building is incomplete and there is no indoor air
       contamination due to vapor intrusion. This example emphasizes the importance of
       building conditions, but it should be noted that this theoretical assumption is unlikely to
       be found under actual site conditions, because foundations may "leak" to some extent, as
       most foundations have some openings that will be conduits to soil gas flow and diffusive
       transport.

    •   Buildings B and C have full-length perimeter cracks in the foundation, are constantly
       under-pressurized, and have different AERs. The vapor intrusion pathway for these
       buildings is complete.

    •   In  Scenario 1, the  vapor source is large and extends beneath the three buildings; in
       Scenarios 2 and 3, a finite source extends below only Building A. Building B is 5 m away
       from the source edge, and Building C is 25 m away from the source edge.

The building conditions for each scenario are presented in Figure 17, from which we note the
following:

    •   In  Scenarios 1, 2 and 3, Building A has no indoor air contamination (a = 0) because the
       foundation is perfectly sealed; therefore, the subsurface vapors do not intrude into the
       building regardless of the subsurface vapor concentration. As discussed above, a
       perfectly sealed foundation is very unlikely to be found under actual site conditions but is
       included here to illustrate the magnitude of change from sealed to cracked condition.

    •   In  Scenario 1, Buildings B and C have similar vapor concentrations beneath the slab and
       the same derived soil gas flow rates (Qs), but the normalized indoor air concentrations (a)
       differ by about a factor of four. The difference in indoor air concentrations results from a
       lower assumed AER and Qbdg for Building B, resulting in less dilution of the
       contaminants in indoor air resulting from vapor intrusion.

    •   In  Scenario 2, Buildings B and C have similar indoor air concentrations (a), although the
       concentration beneath Building C is about two orders of magnitude lower than the
       concentration beneath Building B. The similarity in indoor air concentrations results from
       the higher pressure differential (i.e., a higher Qs) and the lower AER and lower Qbdg
       values assumed for Building C.

    •   In  Scenarios 2 and 3, the normalized indoor air concentrations for Building B differ by
       about one order of magnitude, although the buildings have similar vapor concentrations
       beneath the slab. The difference in indoor air  concentrations is due to the combinations of
       Qs, AER, and Qbdg values, which result in greater vapor intrusion and less dilution of
       indoor air for Building B in Scenario 3.

    •   In  all scenarios, there is spatial variability of the vapor concentration distribution below
       the slab for the three buildings.
                                           38

-------
February 24, 2012
Conceptual Model Scenarios of the Vapor Intrusion Pathway
Building A Buildings B and C
Perfectly Sealed Full length perimeter crack.
Incomplete pathway
„ _ n r, - 8 fiF 4 a - 9 9F-
rw
-2-
E
<"
o, -4-
£
Q.
« -6-
-8-
0
-2-
£


0.1 Jr

^ _^ ^ ^^ ^ ^^
_n^
ia ^°
0.1 o.5 -JU_- 0.5
1 ^\

	 	 >B^
______^-^-
^__^-


_^Q^
J^~ ^
A5 0,6


4




Scenario 1
Building
P(Pa)
Qs (L/min)
AER (1/h)
Qbdg (m3/h)
B C
5 5
5.2 5.2
0.25 1
62.5 250
~~iLl_
0.2
^_ 0.3
0.4
X"^X \ / /^^~-.. \
/ \ / \ \
^07^ ^fl^
0.8 _^°A^
0.9 0.9 0.9
0.5
0.6
0.7
	 0.8
0.9
PHHH|HHHH^HHHH^HHHH^BBB|BHHH^HHHi
10 20 30 40 50 60


__-•/'
,t
_Q
f -e-zrr:
o I Vaoor
-o ~p~ 	 p^»
0 1
^t

£
o) ^
D) -4
§• -6-
g


^^J
/
1 	 Vapo
n 0 n f\ ZlF £ r/ 4 ^F

RA
HB Rc
' J15 \ \ ' "\

^ *> *^ \ \ \ \ | B C 7 1 7.3 1 0.25 1 75 300 \ \ \ w 0 10 20 30 40 50 60 70 80 90 100 x(m) Figure 17. Normalized indoor air concentration (a) for different combinations of building conditions (e.g., pressurization, AER) and sub-slab vapor concentration. The soil vapor concentration contour lines are normalized by the source vapor concentration. The source is at m bgs. Qs is the soil gas flow rate predicted for building pressurization (p), AER is building air exchange rate, and Qbdg is building air flow rate. 39


-------
February 24, 2012                       Conceptual Model Scenarios of the Vapor Intrusion Pathway


4.3.4  Multiple Sources
  Figure 18 illustrates that multiple sources will produce contaminant distribution patterns that differ from those
  associated with a single source. Thus, if field evidence indicates that soil gas concentrations increase with
  distance from the presumed source, the presence of an additional source should be considered.
As previously illustrated, the soil vapor concentration tends to decrease as the distance from the
source increases, and it should not be higher than the concentration at the source. If the vapor
concentration at a sampling point away from the source is higher than the concentration at the
source, and assuming there is no bias in the sampling technique, this may indicate the existence
of other sources that were not previously identified, or that the size, location, and strength of the
identified source may not have been well characterized. An example of a concentration
distribution for a site with multiple sources is presented in Figure 18, which illustrates a site
with two buildings (basement and slab-on-grade) and two vapor sources: a groundwater source
near the building with a basement and another source at the vadose zone closer to the slab-on-
grade building. Both sources are recalcitrant VOCs and have the same vapor concentration of
10,000 ng/m3, both buildings have the  same characteristics (e.g., size, AER, cracks), and the
subsurface is homogeneous. Although the slab-on-grade structure is located 30 m away from the
groundwater source, its indoor air concentration is higher than the indoor air concentration in the
building with a basement located only  10m from the groundwater source, because of vapor
intrusion from the vadose zone source adjacent to the slab-on-grade building.

Characterization of the source concentration distribution and multiple source locations is key to
understanding contaminant distributions and identifying buildings with higher vapor intrusion
risks.
                                            40

-------
February 24, 2012
                                  Conceptual Model Scenarios of the Vapor Intrusion Pathway
                                Vertical Cross-Section View
                    =1.1 ug/m
  tn    .
  a)  -4-
  
n EH
\ /
5

LJUO-
c
c
T-
\
J
D/
1
0
0
c\
n 	

j
;
V
\ Qs= 5 L/min
-\^
Ik^Bi^
^•v
apor Source
	

* \ \ \^?
\ \
it 1
, V
                                     Plan View at 2 m bgs
      60-



      50-



      40-



      30-



      20-



      10-



       0-
          1,000
          2,000
      70-
                                      Plan View at 5 m bgs
60-



50



40-



30-



20-



10-



 0-
                                                            1.000
                                                   //
                                                             §
                                                             0
0
10
20
                           30
                                        40
 50

x(m)
60
70
80
     I ____ ]  Vapor source zone footprint
90
100
    Figure 18. Soil vapor distribution and indoor air (IA) concentration for a scenario with two

                               buildings and two vapor sources.

  Concentrations are in units of |ig/m3. Qs is the soil gas flow rate predicted for building under-pressurized by 5 Pa.
                                             41

-------
February 24, 2012                       Conceptual Model Scenarios of the Vapor Intrusion Pathway
4.4    Subsurface Heterogeneities and Ground Cover

Most simulations in this document model an open ground surface and homogeneous, low
moisture content sandy soils with uniform transport properties in all directions. In reality, soils
are rarely (if ever) homogeneous and are often horizontally layered, and these layers can be
discontinuous and have different moisture conditions depending on how fine grained they are
(e.g., silts and clays hold more moisture than sand and gravel). This has particular importance for
vapor intrusion, because upward and lateral soil vapor migration may be limited by layers with
higher moisture content. In addition, the ground surface may not be open to vapor transport
where there are other buildings or impermeable covers.

The  scenarios presented in this section assume several different configurations that combine the
effects of a layered or heterogeneous subsurface with single or multiple buildings and open
ground or impermeable ground cover.

4.4.1  Moisture Content in Layered Soils
  The figures in this section use a single-building scenario to illustrate how non-homogeneous soils (i.e., soils with
  layers of higher and lower moisture and associated soil gas permeability, which varies inversely with soil
  moisture) can impact the pressure field distribution, soil gas flow patterns, and VOC concentrations in soil gas in
  the vicinity of a building. The impact of the layers depends on their location relative to the source and the building
  foundation. The locations of the soil layers are depicted in Figure 19a. The effects of those soil layer geometries
  on under-pressurized buildings are depicted in Figure 19b. The effects of those soil layer geometries on over-
  pressurized buildings are depicted in Figure 19c.
As discussed previously, the moisture content of the soil affects vapor transport by diffusion and
may also affect advective transport, because higher moisture content decreases soil gas
permeability. The simulations in this section illustrate how moisture content distribution in
layered soils can affect vapor concentrations in soil gas for a simplified scenario of a single
building with laterally continuous soil layers and a uniform groundwater vapor source directly
beneath the building.  The conceptual model scenarios are illustrated in Figure 19a. Scenario A is
homogeneous sandy soil at baseline conditions, used for comparison. Scenario B includes four
layers, with two layers of higher moisture content beneath the foundation. Scenario C includes
six layers, with two layers of higher moisture content beneath the foundation and a third layer at
the ground surface. Scenario D includes two soil layers, with the higher moisture content layer at
ground surface. The layers with higher moisture content have a saturation (S) of 60%
(percentage of water in soil pores relative to total pore  space) and a soil gas permeability (Kg) of
1E-13  m2. The layers  with lower moisture content have an  S of 20% and a Kg of 1E-11 m2 (i.e.,
the baseline soil condition). Note that the impact of even higher moisture content (and lower
permeability) layers (i.e., geologic barriers modeled assuming 95% saturation) is discussed in
Section 4.4.4.

The  simulations were performed for under- and over-pressurized buildings to evaluate the
predicted effect of steady air flow into and out of the building. The predicted soil gas pressure
field, the induced soil gas flow rate (Qs), and the predicted normalized indoor air concentration
(a) and normalized soil vapor concentration distribution are presented in Figures 19b and 19c.
                                            42

-------
February 24, 2012
Conceptual Model Scenarios of the Vapor Intrusion Pathway
^
n
-1-
_•?
-4
_r;
-6
-7-
E -8-,
w
O)
.Q
f 0
CD u
Q 1

o
/I
c

-7-
-8


^4j
!!.
A
n

vapor source
^^^liik^
^i^EiffliiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiMII^^




^^^
j \
c






_, vapor source
u
-1-
-2
4

c
-7-
-8-i


-
-2
-3-
-4
-5
-6
-7-
i -8
^rfSSl^


n ^


B




_ vapor source




n ^
^^ ^
_\i
D


	 	 vapor source


    I  I High permeability: percent saturation (S) = 20%; soil gas permeability (Kg) = 1E-11 m2
    I  I Low permeability: S = 60%, Kg = 1E-13 m2.


 Figure 19a. Full view of the soil layers used in the simulations presented in Figures 19b and 19c.
                                              43

-------
February 24, 2012
                                     Conceptual Model Scenarios of the Vapor Intrusion Pathway
                                    Building Under-pressurized 5 Pa
                                                                                    Soil layers
         -4-
         -6-
              Qs=4^min jJrT^X
         -6-
             Qs = 3.2 L/min
                                                                    0.1
                                                   0.5
                                                  -0.6

                                                  —0:9
Q.
0)
Q
                                                                          -O2-
                                                      a = 3.3E-4
                                                                     -as
                                                    0.7

                                                    0.9
                                                      a = 9.7E-4M
                                                            [
                                                                     -az_
                                                                0.8
                                                      0.9
                                                                                         B
                                                                                             D
                                        10    12  0
                                              x(m)

    I   I High permeability: percent saturation (S) = 20%; soil gas permeability (Kg) = 1E-11 m2
    I   I Low permeability: S = 60%, Kg = 1E-13 m2
    The arrows indicate soil gas flow direction.

    Figure 19b. Effect of soil layers (Figure 19a) on pressure field, soil vapor distribution, and
          normalized indoor air concentration (a) for building under-pressurized by 5 Pa.
 The soil gas gauge pressure contour lines are normalized by indoor air gauge pressure. Qs is the predicted  soil gas
flow rate. The soil vapor concentration contour lines are normalized by the source vapor concentration. The source is
                                             at 8 m bgs.
                                                44

-------
February 24, 2012
Conceptual Model Scenarios of the Vapor Intrusion Pathway
                                  Building Over-pressurized 5 Pa
                                                                                    Soil layers
                                                                                            B
    I   I High permeability: percent saturation (S) =20%; soil gas permeability (Kg) = 1E-11 m2
    I   I Low permeability: S = 60%, Kg = 1E-13 m2

     Figure 19c. Effect of soil layers (Figure 19a) on pressure field, soil vapor distribution, and
          normalized indoor air concentration (a) for buildings over-pressurized by 5 Pa.
 The soil gas gauge pressure contour lines are normalized by indoor air gauge pressure. Qs is the predicted soil gas
flow rate. The soil vapor concentration contour lines are normalized by the source vapor concentration. The source is
                                            at 8 m bgs.
                                                45

-------
February 24, 2012                      Conceptual Model Scenarios of the Vapor Intrusion Pathway
The presence and position of different soil layers can affect the subsurface pressure field and the
soil vapor concentration distribution. The pressure profiles presented in Figures 19b and 19c
show how the position of layers with higher moisture content and lower gas permeability
influence soil gas flow. Relative to Scenario A (homogeneous lower moisture content case), the
soil gas flow rate (Qs) is reduced by more than 50% in the scenarios with a high moisture content
layer on the ground surface (Scenarios C and D). In Scenario B, the higher moisture content
layers below the building reduce the soil gas flow rate (Qs) by 20% relative to Scenario A. In
general, the soil moisture condition close to the building affects the air permeability and flow; as
the soil moisture content increases, the predicted flow of soil gas (into and out of the building)
decreases.

The soil vapor concentration profiles presented in Figures 19b and 19c show that if the layers
with higher moisture content are between the source and the foundation, then contaminant
migration toward the foundation is reduced, the foundation has less influence on the
concentration profile, and the sub-slab soil vapor concentration is lower compared with the
homogeneous scenario. In the scenarios with high soil moisture content near the ground surface,
the migration of contaminant vapors from soils to the atmosphere is reduced, resulting in higher
soil vapor concentrations near the surface and beside the foundation wall. For Scenarios B and C
with steady building under-pressurization (Figure 19b), the normalized indoor air concentrations
(a) are similar (3.0E-4 and 3.3E-4, respectively) because the higher soil gas flow rate (Qs) in
Scenario B is offset by the lower soil gas concentration near the crack.  In these scenarios, the
layered soils with higher moisture content layers between the source and the foundation reduced
the normalized indoor air concentrations by about a factor of four compared with the
homogeneous Scenario A, with a normalized indoor air concentration of 1.2E-3. Although
Scenario D has a higher vapor concentration around the foundation, the normalized indoor air
concentration for this scenario (9.7E-4) is about 20% less than the normalized indoor air
concentration for the homogeneous scenario (Scenario A). The reduced soil gas flow rate (Qs)
under the conditions  simulated in Scenario D (due to higher moisture content layer on the ground
surface) reduces vapor emissions into the building.

For the scenarios with steady building over-pressurization (Figure 19c), the normalized indoor
air concentrations are several orders of magnitude smaller than the ones predicted for a steady
under-pressurized building (Figure 19b).
                                           46

-------
February 24, 2012                       Conceptual Model Scenarios of the Vapor Intrusion Pathway


4.4.2  Lower Moisture Content Below the Building
  The simulations in this section further illustrate how nonhomogeneous soil conditions can impact the soil gas
  flow into the building and VOC concentrations in soil gas in the vicinity of a building and in the indoor air. These
  simulations expand on the concepts in Section 4.4.1 by varying the moisture content, and thus soil gas
  permeability, laterally as well as vertically. They simulate conditions that might be encountered when the
  presence of the building results  in reduced soil moisture immediately beneath it. The impact of the layers
  depends on their location relative to the source and the foundation (Figures 20a through d).
The simulations in this section illustrate conditions where moisture content is lower below the
building than in the subsurface beside the building (Tillman and Weaver, 2007) or lower than in
the layer on top of the source. The conceptual model scenarios illustrated in Figure 20 represent
a single building with a finite vapor source directly under the building at a groundwater level of
8 m bgs. The building is at baseline conditions (under-pressurized by 5 Pa, perimeter crack).
Scenario A is the homogeneous baseline soil condition, used for comparison.  In Scenario B, the
pore water saturation (S) is 15% below the building and 40% in the subsurface next to the
building. In Scenario C, S is 60% in a 3 m thick layer directly above the vapor source and 20% in
the overlaying subsurface. Scenario D is a combination of Scenarios B and C. The permeability
is not uniform and decreases  with increasing moisture content in these simulations, as noted in
the legend beneath each figure.

The normalized soil vapor concentration distribution, the soil gas flow rates (Qs), and the
normalized indoor air concentration (a) for each scenario are presented in Figure 20.  In Scenario
B, the higher moisture content next to the building creates a barrier to vapor transport toward the
ground, slightly increasing the vapor concentration below the building compared with the
homogeneous scenario (Scenario A). The predicted  soil gas flow rate (Qs) and the normalized
indoor air concentration (a) in Scenario B are about 30% lower than those in Scenario A. In
Scenario C,  the higher moisture content layer right on top of the vapor source decreases the
concentration of vapors below the building and the normalized indoor air concentration by about
a factor of five compared with the ones in Scenario A. In Scenario D, the higher moisture content
next to the building slightly changes the results from Scenario C, with Qs decreasing  by  30%, the
normalized soil vapor concentration increasing by a factor of two, and a similar normalized
indoor air concentration. For the conditions simulated, higher moisture content on top of the
vapor source affects the soil vapor concentration distribution and the indoor air concentrations
more than higher moisture conditions next to the building do.
                                            47

-------
February 24, 2012
Conceptual Model Scenarios of the Vapor Intrusion Pathway
Conceptual scenarios
^^=illllik
A

-2

-4-
-6-






HH
=^
	 f


S 20%

3
\




and Predicted Qs Soil Vapor Concentration Distribution and a
Qs= 4.0 L/min 1 p, p-p-J a=1.2E-3





_ vapor source



-
-

-I=^J I S^flP
P^^l1 ZoT^i am
07 0.3 *\

\
K I ^i







 E_

 §
B
o


-4-
-6-
R-


S 40%
,™J!
n EB


S 15%
jpor sour
Qs = 2.7 L/min j 	 ~ 	 [ a - y.ut-4


S 40%
e


-
-
&il^fl^x
0\7\ 0-4
, «
/ //J
m ^
^>Q1
\
\ \
\ \
c

n =

— \
S 20%
Qs = 3.8 L/min

S 60%
T vapor source
D


-4-
-6-
-8

S 40%

n =
PHI
S1S%

Qs= 2.5 Umin



S 60%
_ vapor source
     0     10     20     30    40    50
                                         60
                                                       10    20    30    40    50     60
    S = Percent saturation (percentage of soil pores filled with water)
    ForS= 15% and 20%, gas permeability (Kg) = 1E-11 m2; for S = 40% and 60%, Kg = 1E-13 m2.

  Figure 20. Soil vapor distribution and normalized indoor air concentration (q) for scenarios with
               different soil moisture content in the subsurface and below building.
   The soil vapor concentration contour lines are normalized by the source vapor concentration. The source is at
              8 m bgs. Qs is the soil gas flow rate predicted for building under-pressurized  by 5 Pa.
                                                48

-------
February 24, 2012                       Conceptual Model Scenarios of the Vapor Intrusion Pathway


4.4.3  Heterogeneous Subsurface, Finite Sources, and Ground Cover
  The simulations in this section further illustrate how non-homogeneous soil conditions can impact the soil gas
  flow into the building and VOC concentrations in soil gas in the vicinity of a building and in the indoor air.
  These simulations expand on the concepts in Sections 4.4.1 and 4.4.2 by depicting a broad range of soil
  moisture distributions,  source depths and locations, and ground cover scenarios for the same building
  conditions at scenarios with single or multiple buildings (with basement or slab-on-grade foundations). The
  simulations illustrate how high moisture content layers & impermeable ground cover can influence vapor
  intrusion differently for shallow (Figures 21 a and b), and deep (Figures 22a and b) water table sources where
  the building  is laterally separated from a finite source. They also depict the influence of discontinuous layers in
  settings where multiple buildings overlie a finite water table vapor source (Figures 23a and b) and where the
  source is laterally offset from one or more buildings (Figures 24a and b). The simulations illustrate that the
  indoor air concentrations can vary by many orders of magnitude depending on the configuration of the layers,
  the buildings, and the source.
This section presents a variety of scenarios with single or multiple buildings, finite sources,
continuous or discontinuous soil layers, and an impermeable cover on the ground surface. The
set of scenarios presented illustrates the effect of layers on the lateral migration for scenarios
with a single building and the effect of heterogeneous conditions for scenarios with multiple
buildings. These scenarios may  help illustrate the spatial variability in the sub-slab concentration
of the same building or between buildings at the same site. Note that the impermeability to vapor
flow through a ground cover is a theoretical assumption intended to represent a very low
permeability layer, such as a concrete pad; at actual sites, the permeability of such a barrier to
vapor flow can be much higher  due to cracks and other imperfections.

Figure 21a presents a set of simplified model scenarios that illustrate the effect of laterally
continuous layers, impermeable ground cover for shallow groundwater (3 m bgs), and a finite
vapor source located at a lateral distance of 20 m from a building. Scenario A is the
homogeneous baseline soil condition, used for comparison. In Scenario B, a layer of higher
moisture content (1 m thick) is on top of the vapor  source at groundwater level (3 m depth). In
Scenario C, a layer of higher moisture content is  at the ground surface. In Scenario D, there is an
impermeable cover at the ground surface extending from  the building and partially over the
source. Figure 21b presents the predicted normalized soil vapor concentration distribution, soil
gas flow rate (Qs), and the indoor air concentration for the scenarios described in Figure 2la. In
Scenario B, the high moisture content layer on top  of the  source reduces the vapor concentrations
in the subsurface close to the building and in the  indoor air by about two orders of magnitude
compared with the homogeneous scenario (Scenario A). In Scenario C, the high moisture content
layer on the ground surface promotes the migration of vapors to further lateral distances and
increases the vapor concentrations in the subsurface and in the indoor air by about two orders of
magnitude compared with Scenario A. Likewise, the impermeable surface in Scenario D
increases the lateral migration of vapors and  increases the vapor concentrations close to the
building and in the indoor air by about three  orders of magnitude compared with Scenario A.
Also of note are the differences  in concentration beneath the slab; for example, in each scenario,
the sub-slab soil gas concentration declines by about an order of magnitude from one side of the
building to the other.
                                             49

-------
February 24, 2012
Conceptual Model Scenarios of the Vapor Intrusion Pathway


-1-

-
0

-1-
9
0
^ c
D)
.0
"o n
(D
Q 1



(

-1-
0


A


10 20 3(
B



10 20 3
^
C




D 10 20 3
D


o 10 20 ;
^iili.

g

D ^s.4

E^
— A

D 4
FE
; I
? — A

0 >•
n g
g

0



vapor source
0 50 60 70 80 90 10



vapor source
0 50 60 70 80 90 1C
K



vapor source
tO 50 60 70 80 90 1(
] Impermeable Cover

vapor source
40 50 60 70 80 90 1
x(m)




0




0




DO



00
    I  I High permeability: percent saturation (S) = 20%; soil gas permeability (Kg) = 1E-11 m2
    I  I Low permeability: S = 60%, Kg = 1E-13 m2.

  Figure 21a. Soil layers and ground cover scenarios used in the simulations presented in Figure
                      21 b with a shallow laterally separated vapor source.
                                             50

-------
February 24, 2012
                          Conceptual Model Scenarios of the Vapor Intrusion Pathway
                                                                                 Soil layers
                                                                                    LI \\j\\j\jy
 w
 en
 .a

H

9

Qs = 0.05 L/min



V
na
Pn


lEp
3



1
a=l.lE-ll
/ I n -I

1 / / /^= 0.2
ie W-4 0.01/J
JSSSSfc_QJ ^^54

^^








     0-
    -1
    -2H
    -3
                Qs= 1.4 L/min
1B-5
                            a = 9.1E-6
0
                                                                            90
                                                                      100
   Figure 21 b. Effect of soil layers and ground covers (Figure 21a) on soil vapor distribution and
      normalized indoor air concentration (a) for a shallow laterally separated vapor source.
   The soil vapor concentration contour lines are normalized by the source vapor concentration. The source is at
             3 m bgs. Qs is the soil gas flow rate predicted for building under-pressurized by 5 Pa.

Figure 22a presents a set of conceptual model scenarios that illustrate the effect of continuous
layers for deep groundwater (8 m bgs) and a finite vapor source located at a lateral distance of 20
m from a building. Scenario A is the homogeneous baseline soil condition, used for comparison.
In Scenario B, a layer of higher moisture content (3 m thick) is on top of the vapor source at
groundwater level. In Scenario C, a 2 m thick layer of higher moisture content extends from
depths of 3 to 5 m bgs between the foundation and the source. In Scenario D, a 1 m thick layer of
higher moisture content is on the ground surface. Figure 22b presents the predicted normalized
soil vapor concentration distribution, soil gas flow rate (Qs), and the indoor air concentration for
the scenarios described in Figure 22a. In Scenario B, the high moisture content layer on top of
                                            51

-------
February 24, 2012
Conceptual Model Scenarios of the Vapor Intrusion Pathway
the source reduces the vapor concentrations in the subsurface close to the building and in the
indoor air by about one order of magnitude compared with the homogeneous scenario (Scenario
A). In Scenario C, the predicted soil vapor and indoor air concentrations are similar to those in
Scenario A. Although there is a higher moisture content layer between the source and the
foundation, there is substantial lateral migration through the lower moisture content layer right
above the source. In Scenario D, the high moisture content layer on the ground surface increases
the lateral migration of vapors and increases the vapor concentrations throughout the subsurface
and in the indoor air by about one order of magnitude compared with Scenario A.



-4-
-6-



-2-
-4-
-6-
8-




-4-
-6-



-4-
-6-

A



B




C





D



o 10 20 :
Hffl
|^ j
— ^y

"T1™
=^i|
	 -r\


^fc
|^
| 	 A



!!!••••••••••••••••••!
&
: 	 tx

0



vapor source




vapor source
¥
1
|


vapor source
3


vapor source
40 50 60 70 80 90 1C
x(m)
          O High permeability: percent saturation (S) = 20%; soil gas permeability (Kg) = 1E-11 m2
          I  I Low permeability: S = 60%, Kg = 1 E-13 m2.

   Figure 22a. Soil layer scenarios used in the simulations presented in Figure 22b with a deep
                              laterally separated vapor source.
                                            52

-------
February 24, 2012
                             Conceptual Model Scenarios of the Vapor Intrusion Pathway
         0)
         O)
         JD
                                             oc = 1.3E-5  Qs = 4 L/min
                                              a = 4.3E-7 Qs = 3.8 L/min
                                       I=HI    a = 1.3E-5  Qs  = 3.3 L/min
                                                                                Soil layers
 0

-2-

-4-

-6-
                                              a = 7.6E-5   Qs = 2.3 Umin
                                           CL1
                    1E-3
                                                (fo To/4 /

                               001
               0     10     20     30     40     50    60     70     80    90     100
                                              x(m)

  Figure 22b. Effect of soil layers (Figure 22a) on soil vapor distribution and normalized indoor air
                   concentration (a) for a deep laterally separated vapor source.
   The soil vapor concentration contour lines are normalized by the source vapor concentration. The source is at
             8 m bgs. Qs is the soil gas flow rate predicted for building under-pressurized by 5 Pa.
                                                53

-------
February 24, 2012                     Conceptual Model Scenarios of the Vapor Intrusion Pathway
Figure 23a presents a set of conceptual model scenarios that illustrate the effect of a
heterogeneous subsurface and impermeable ground cover for deep groundwater (8 m bgs) and a
finite vapor source located directly beneath two separated buildings with basements. Scenario A
is the homogeneous baseline soil condition, used for comparison. In Scenario B, a discontinuous
soil layer of higher moisture content (2 m thick) extends below the first foundation, but is
discontinuous below the second foundation. In Scenario C, there is an impermeable cover at the
ground surface between the two buildings that extends about 10m away from the first building,
which has the baseline homogeneous subsurface conditions. Scenario D has the same
impermeable ground cover presented in Scenario C, with a discrete higher moisture content layer
2 m thick extending beneath the two buildings.

Figure 23b presents the predicted normalized soil vapor concentration distribution, soil gas flow
rate (Qs), and the indoor air concentration for the scenarios described in Figure 23a. In Scenario
B, the discontinuous layer beneath the buildings creates considerable spatial variability in the soil
vapor concentrations, with the shallow concentrations on the sides of the buildings varying by
about a factor of 10 and the indoor air concentration of the buildings  varying by about a factor of
four compared with the homogenous scenario (Scenario A). The indoor air concentration of the
first building in Scenario B (with the layer beneath it) is a factor of four smaller than in Scenario
A. The second building (without the layer beneath it) has a similar indoor air concentration to
that in Scenario A. In Scenario C, the impermeable cover prevents the migration of vapors to the
atmosphere, which increases the vapor concentrations in the subsurface beneath it by about a
factor of eight compared with the concentration under the bare ground surface.  Note that the
concentration around the perimeter crack of Scenario C is about a factor of 1.6  higher than the
concentration at the perimeter crack in Scenario A, and the soil gas flow rate (Qs) in Scenario C
is about a factor of 1.4 smaller than the Qs in Scenario A; therefore, the contaminant emission
rate to the enclosed space and the indoor air concentration are similar in both scenarios. In
Scenario D, the continuous layer below the foundations reduces the vapor migration from the
source to the buildings. The sub-slab concentrations and the indoor air concentrations of the two
buildings are similar and about a factor of 10 smaller than in Scenarios A and C with
homogeneous soil conditions.
                                           54

-------
February 24, 2012
Conceptual Model Scenarios of the Vapor Intrusion Pathway
                0

                -2-

                -4-

                -6-
                                           Vapor Source


                                                    niii!

                 o*	ii   mi	ia

                -2-

                -4-

                -6-
             -~.                              Vapor Source
             ^5,  -8^*	1	psssssssssssss^^

             D)

             £^       Impermeable Cover ^


                -2-

                -4-

                -6-
                                            Vapor Source



                      Impermeable Cover,


                 -2-

                 -4-

                 -6-
                                           Vapor Source

                   0     10    20     30    40     50     60    70     80     90    100
                                                  x(m)
    I  I  High permeability: percent saturation (S) = 20%; soil gas permeability (Kg) = 1 E-11 m
    I  I  Low permeability: S = 60%, Kg = 1 E-13 m2.

    Figure 23a. Discontinuous soil layers and ground cover scenarios used in the simulations
         presented in Figure 23b for two buildings separated by 10 m overlying a plume.
                                             55

-------
February 24, 2012
Conceptual Model Scenarios of the Vapor Intrusion Pathway
              a=1.2E-3
              Qs = 4 L/min
                  a=1.2E-3
                  Qs = 4 L/min
Soil layers
                a = 3.0E-4
                Qs = 3.3 L/min
                 a=l.lE-3
                 Qs = 3.9 L/min
                        n       ,      Vapor Source;       ,
                                     Vapor Source
                10      20     30      40      50     60

           ~~-  Layer footprint                 x (m)
                     70     80      90      100
    Figure 23b. Effect of discontinuous soil layers and ground cover (Figure 23a) on soil vapor
   distribution and normalized indoor air concentration (a) for two buildings separated by 10 m.
   The soil vapor concentration contour lines are normalized by the source vapor concentration. The source is at
             8 m bgs. Qs is the soil gas flow rate predicted for building under-pressurized by 5 Pa.
                                              56

-------
February 24, 2012                     Conceptual Model Scenarios of the Vapor Intrusion Pathway


Figure 24a presents a set of conceptual model scenarios that illustrate the effect of a
heterogeneous subsurface and impermeable ground cover for deep groundwater (8 m bgs) and a
finite vapor source located at a lateral distance of 20 m from two adjacent buildings, one with a
slab-on-grade foundation and another with a basement foundation. Scenario A is the
homogeneous baseline soil condition, used for comparison. In Scenario B, there is an
impermeable cover at the ground surface extending from the slab-on-grade building to about 10
m over the source, and the subsurface has the baseline homogeneous conditions. Scenario C has
the same impermeable ground cover as Scenario B and a discrete higher moisture content layer
(2 m thick) extending from beneath the slab-on-grade building to about 5 m beyond the source
edge.

Figure 24b presents the predicted normalized soil vapor concentration distribution, soil gas flow
rate (Qs), and the indoor air concentration for the scenarios described in Figure 24a. In Scenario
B, the impermeable cover does not allow the migration of vapors to the atmosphere, increasing
the vapor concentrations in the subsurface by about a factor of six compared with the
concentration under the bare ground surface in Scenario A. The cover also promotes the
migration  of vapors to further lateral distances, increasing the vapor concentrations below the
foundations and in the indoor air concentration by factors of 2.5 and 5, respectively, compared
with Scenario A. In Scenario C,  the discontinuous layer with higher moisture content does not
have a substantial influence on the vapor concentration distribution because there is still
considerable surface area with low moisture content in the subsurface for migration of the
contaminant vapors and the vapors simply diffuse around and through the discrete high moisture
content layer.
                                           57

-------
February 24, 2012
Conceptual Model Scenarios of the Vapor Intrusion Pathway


n A
u
-2
-4
-6
-8

1 "2
w
E5 -4-
.c
"S- «
ver
Vapor Source
I I
.rfi-nllihis, ^rfiiill
c

n ^
i^i


I

i
ihla

cover



0 10 20 30 40

50 60
x(m)
Vapor Source

70 80 90 100
    O  High permeability: percent saturation (S) = 20%; soil gas permeability (Kg) = 1E-11 m
    CZI  Low permeability: S = 60%, Kg = 1E-13 m2.

    Figure 24a. Discontinuous soil layers and ground cover scenarios used in the simulations
                presented in Figure 24b for two adjacent buildings near a plume.
    A finite vapor source is located laterally 20 m away from the closest building at groundwater level of 8 m bgs.
                                              58

-------
February 24, 2012
                                       Conceptual Model Scenarios of the Vapor Intrusion Pathway
     o-
   -2-

   -4-


   -6-

   -8
w
D)   -4
 \
Vapor Source
T|| teest t t 888&^
0 10 20 30 40 50 60 70 80 90








1C
       i	1 Layer footprint                   x (m)

    Figure 24b. Effect of discontinuous soil layers and ground cover (Figure 24a) on soil vapor
 concentration distribution and normalized indoor air concentration (a) for two adjacent buildings.
   The soil vapor concentration contour lines are normalized by the source vapor concentration. The source is at
             8 m bgs. Qs is the soil gas flow rate predicted for building under-pressurized by 5 Pa.
                                              59

-------
February 24, 2012                       Conceptual Model Scenarios of the Vapor Intrusion Pathway


4.4.4  Geologic Barrier
  The simulations in this section further illustrate how nonhomogeneous soil conditions can impact the soil gas flow
  into the building and VOC concentrations in soil gas in the vicinity of a building and in the indoor air. These
  simulations expand on the concepts in Sections 4.4.1 through 4.4.3 by depicting the influence of low permeability
  soil layers that can act as "barriers" to gas migration (which are modeled here as soil layers with 95% pore water
  saturation) over a broad range of soil layering profiles, source depths and locations, and building scenarios.  The
  simulations illustrate that such barrier layers can lead to a sharp concentration change with up to an order of
  magnitude decrease in concentrations between the area beneath the geologic barrier and the area above it
  (Figure 25). Figures 26 and 27 highlight the fact that differences in the relative positions of the source, the
  barrier, and the structure can result in very different sub-slab contaminant profiles and indoor air concentrations.
In this document, "geologic barrier" is used to indicate a natural layer in the subsurface that
hinders the movement of vapors to a greater extent than the soil layers modeled in the previous
section. In the simulations presented in this section, a geologic barrier is represented as a thin soil
layer with 95% pore water saturation (S). In natural settings, this condition could exist in areas
where, for example, there is ponding of infiltrating water on top of a fine-grained soil layer (e.g.,
water from natural recharge or irrigation, leaky water or sewer pipes). The high moisture content
layer properties used in these simulations may not be typical of real sites, but they are a
convenient modeling mechanism for simulating low permeability barriers and their influence on
the subsurface distribution of VOCs at a vapor intrusion site. The 95% saturated layer portrayed
in this document has a soil gas permeability of 1 x  10"13 m2, roughly equivalent to a soil layer of
moist clay.

The effect of a geologic barrier depends on its position and size with respect to the source, the
building foundation, and the ground surface. The scenarios simulated in this section illustrate
different configurations of geologic barriers with respect to these conditions for single and
multiple buildings.  Similar trends were observed by Bozkurt et al. (2009).

Figure 25 presents the modeled scenarios and the predicted effect of geologic barriers on
normalized soil vapor concentration distribution, soil gas flow rate (Qs), and indoor air
concentration for conceptual model scenarios represented by a single building and a large vapor
source directly beneath the building at groundwater level (5 m bgs). Scenario A is the
homogeneous baseline soil condition, used for comparison. In Scenario  B, the barrier is between
the source and the building and extends laterally beneath the full extent  of the foundation. In
Scenario C, the barrier is between the source and the building but does not extend beneath the
foundation. In Scenario D, the barrier is at the ground surface. Note that, in all scenarios, the
barrier is discontinuous at locations away from the building.

The results presented in Figure 25 show that,  for the conditions simulated, the predicted vapor
concentration below the geologic barrier is about one order of magnitude higher than the vapor
concentration above it. The geologic barriers reduced the soil gas flow rate (Qs) in Scenarios B,
C, and D by about 40% compared with the homogeneous case (Scenario A). In Scenario B,
where the geologic barrier extends below the  foundation, the normalized indoor air concentration
(a) is about one order of magnitude smaller than in the homogeneous case. For scenarios where
the geologic barrier does not extend below the foundation (Scenarios C  and D), the normalized
indoor air concentrations  are similar to  the homogeneous case.
                                             60

-------
February 24, 2012
Conceptual Model Scenarios of the Vapor Intrusion Pathway
      A   Conceptual scenarios and Predicted Qs
            Soil Vapor Concentration Distribution and a
    I  I High permeability: percent saturation (S) = 20%; soil gas permeability (Kg) = 1E-11 m2
    I  I Low permeability barrier: S = 95%, Kg = 1E-13 m2.

  Figure 25. Effect of geologic vapor barriers on soil vapor distribution and normalized indoor air
                                     concentration (a).
   The soil vapor concentration contour lines are normalized by the source vapor concentration. The source is at
             5 m bgs. Qs is the soil gas flow rate predicted for building under-pressurized by 5 Pa.

The next two figures present scenarios with finite sources and multiple buildings. Figure 26
shows two buildings with basements that are 10m apart and a geologic barrier extending fully
beneath only one of the two buildings. Figure 27 shows two adjacent buildings with basements
and a geologic barrier extending up to the edge of the second building. In Figure 26, the
normalized indoor air concentration predicted for the building above the geologic barrier is more
than a factor of 10 smaller than the concentration predicted for the building that is not above the
barrier. In Figure 27, the indoor air concentration of the building right at the edge of the geologic
barrier is a factor of four higher than the  concentration of the building that is fully shielded by
the geologic barrier. The examples in Figures 26 and 27 show that, although the primary reason
for the reduced normalized indoor air concentration is the effect that the geologic barrier has  on
reducing vapor migration by diffusion, the barrier also reduces the soil gas flow rate into the
building due to its low soil gas permeability.  This effect is more pronounced in the scenario with
two adjacent buildings (Figure 27).
                                             61

-------
February 24, 2012
Conceptual Model Scenarios of the Vapor Intrusion Pathway
                                  Vertical Cross-Section View
                                a = 7.0E-5         a=1.0E-3
       Stratigraphic Barrier      QS = 3-5 L/min    Qs= 4.0 L/min
       (95% water saturation)
       70

       60

       50
                                      Plan View at 2 m bgs
       20

       10-

         0
                                                                               .01
/ u
fin


r- s\
O U

40
30
on
zU
10
n
.-/


i
/
1
01
\
1






/
/

I







/

\
\







/









/

\
\









\
^


-— ^^^^^ ^^^^^J

-^^\
1
1
0.9 0.9
1 i i
1
1

~— — 	 	 	 	 	 — — -
^-^^^ \
~~~ — 	 	 	 — ~ ^^^\ ^^^—
•^z — ~ — ~~--~. ^^ \
-~~- — ~ — ~-~~. \ \ \
-\i o u1
\ 1 \ \ \ \
01
ty } o.b1 02
1
JJ J J /
^__ 	 ^^^^^ J
.s^ /
/^^ /
                  10     20      30     40     50      60     70     80
                                       90     100
               Geologic barrier footprint
               .	I Vapor source zone footprint
  Figure 26. Effect of a geologic vapor barrier on soil vapor distribution and normalized indoor air
                     concentration (a) for two buildings separated by 10 m.
   The soil vapor concentration contour lines are normalized by the source vapor concentration. The source is at
             8 m bgs. Qs is the soil gas flow rate predicted for building under-pressurized by 5 Pa.
                                             62

-------
February 24, 2012
                     Conceptual Model Scenarios of the Vapor Intrusion Pathway
     Stratigraphic Barrier
     (95% water saturation)
                                 Vertical Cross-Section View
                             a = 8.3E-5       a = 3.5E-4
                             Qs = 2.8 L/min   Qs = 2.9 L/min
   70
   60
   50
I40"
^ 30
   20
   10
    0
   70
   60
   50
-^40
 ^30
   20
   10-
    0
           0
                                     Plan View at 2 m bgs
                                      Plan View at 5 m bgs
                0.
                                                   O.B
                                           0.5 I
                                              I
                  \
0.01
                                                                               /
10     20      30     40      50     60      70     80
90     100
                Geologic barrier footprint
                                   .	I Vapor source zone footprint
  Figure 27. Effect of a geologic vapor barrier on soil vapor distribution and normalized indoor air
                         concentration (a) for two adjacent buildings.
   The soil vapor concentration contour lines are normalized by the source vapor concentration. The source is at
             8 m bgs. Qs is the soil gas flow rate predicted for building under-pressurized by 5 Pa.
                                             63

-------
February 24, 2012                       Conceptual Model Scenarios of the Vapor Intrusion Pathway
                             [This page intentionally left blank.]
                                             64

-------
February 24, 2012                      Conceptual Model Scenarios of the Vapor Intrusion Pathway
5.0   Factors Affecting Vapor Migration and Indoor Air Concentrations
       of Biodegradable VOCs
  In previous chapters, it was assumed that the VOCs depicted in the simulations were recalcitrant (i.e., were not
  subject to rapid breakdown in the subsurface). In this chapter, the VOCs depicted in the simulations are subject to
  aerobic biodegradation, or biodegradation that occurs in the presence of oxygen. Because oxygen is necessary
  to support the bacterial communities that foster aerobic biodegradation of the VOCs, the simulations include
  depictions of the distribution of oxygen concentrations in the subsurface as well as the distribution of the VOCs.
  The simulations cover many of the same topics covered in Section 3 and Section 4 where recalcitrant
  compounds were addressed. The simulations in this chapter are applicable to petroleum hydrocarbons.
Petroleum hydrocarbons and chlorinated hydrocarbons differ in their potential for vapor
intrusion, mainly because petroleum compound vapors readily biodegrade in the subsurface
(U.S. EPA, 2011). Biodegradation is the decomposition of organic contaminants by
microorganisms, mainly bacteria. If the microorganisms use oxygen to break down the VOCs,
the mechanism is called aerobic biodegradation. As summarized in U.S. EPA (2011), substantial
reduction of the vapor concentration of many petroleum hydrocarbons via aerobic
biodegradation has been observed by several researchers in natural settings (e.g., Roggemans et
al., 2001; Hers et al., 2000) and in controlled experimental settings (e.g., Pasteris et al., 2002; Jin
et al., 1994). Aerobic biodegradation  does reduce vapor intrusion into buildings if the VOC is
aerobically biodegradable and oxygen is present. Because aerobic biodegradation depends on the
availability of oxygen, the simultaneous transport of atmospheric oxygen into the subsurface soil
gas is an important factor in the aerobic biodegradation of hydrocarbons.

The fate and transport of aerobically biodegradable compounds includes the same processes of
diffusion and advection discussed in Section 3, with the addition of aerobic biodegradation. This
section presents the effect of several factors on the fate and vapor intrusion of biodegradable
hydrocarbons, including subsurface oxygen availability: source vapor concentration, source
depth and lateral distance from the building, building foundation type, layered soils moisture
content distribution, and geologic barriers.

The 3-D model was used to simulate the simultaneous transport and biodegradation of
hydrocarbons and oxygen. The atmosphere is a constant source of oxygen through the open
ground surface area next to the building, and the VOC  source is assumed to be infinite (i.e., it has
constant concentration and does not deplete over time). Predicted concentration profiles for
hydrocarbon and oxygen are presented and discussed for a variety of scenarios similar to those in
Section 4. As before, the hydrocarbon concentration profiles are normalized by the source vapor
concentration, and the oxygen concentration profiles are normalized by the atmospheric oxygen
concentration.

In all simulations, the threshold oxygen concentration for biodegradation to occur was assumed
to be 1% by volume (which corresponds to a normalized oxygen concentration of 0.05 in the
contour plots). The  simulations employ a first-order biodegradation model with a biodegradation
rate (X)  of 0.18 h"1 for aromatic hydrocarbons, following Abreu and Johnson (2006). This
biodegradation rate is smaller than the average of 0.79  h"1 reported for aromatic hydrocarbons in
the analysis of DeVaull (2007), who compiled results from 84 data sets of laboratory and field
                                            65

-------
February 24, 2012                      Conceptual Model Scenarios of the Vapor Intrusion Pathway


biodegradation rates for aromatic hydrocarbons measured by multiple investigators. A range of
biodegradation rates (0-1.8 h"1) was also assumed for comparative purposes in several scenarios.

All simulations presented in this technical document  assume a single-component vapor source
with physical-chemical properties for benzene, which are similar to those for the VOCs of
interest in vapor intrusion. For recalcitrant chemicals, the model-predicted steady-state
normalized soil vapor concentration distribution and  normalized indoor air concentration (a) for
each chemical are independent of presence and concentration of other chemicals; however, that
is not true in aerobic biodegradation scenarios, because many chemicals utilize oxygen and
contribute to its depletion in the subsurface. For example, petroleum hydrocarbon releases
involve mixtures of aerobically biodegradable VOCs. A modeling study by Abreu et al.
(2009a,b) compared predicted VOC concentrations and oxygen profiles for cases involving
single- and multi-component sources with the same total source concentration. For cases where
oxygen is limiting and biodegradation rates are variable but fast compared with diffusive time
scales, the vapor profiles of individual components were similar. This behavior has been
observed in the field (i.e., Roggemans et al., 2001). Therefore, the simulations presented below
are for a  single-component source but are likely also  applicable to a range of multi-component
scenarios involving aerobically biodegradable chemicals.

As discussed below, for certain source concentrations and depths, the oxygen concentrations in
the subsurface may be depleted, creating anaerobic zones.  Under those conditions, methane gas
may be generated. Methane is readily biodegradable  aerobically, so it would also contribute to
oxygen utilization and affect the vapor profile. Methane production and transport are not
addressed in this document, but it should be noted that methane may be the dominant vapor
component (present at 1-20% by volume) at some petroleum sites.

5.1    Source Concentration
  The simulations in this section illustrate the effect of source concentration on the distribution of biodegradable
  hydrocarbon vapors in the subsurface for buildings with basement (Figures 28 and 30) and slab-on-grade
  (Figures 29 and 31) foundations. Where the oxygen concentration is sufficient for biodegradation, hydrocarbons
  are broken down as oxygen is consumed. High hydrocarbon source concentrations can deplete oxygen, after
  which degradation diminishes and vapor transport is similar to that for recalcitrant compounds. Biodegradation
  typically reduces hydrocarbon vapor concentrations by several orders of magnitude over distances as short as a
  few meters or less. (For comparisons with scenarios where the VOCs are recalcitrant, see Figures 7 and 8.)
The source vapor concentration influences the soil vapor concentration distribution and the
indoor air concentrations of aerobically biodegradable hydrocarbons. Figures 28 and 29 present
the simulated effect of source vapor concentration on normalized soil vapor concentration
distributions for hydrocarbons and oxygen undergoing aerobic biodegradation for a building with
a basement and a building with a slab-on-grade foundation, respectively. The source vapor
concentrations simulated in each figure are 20,000, 100,000, and 200,000 mg/m3. A hydrocarbon
vapor source concentration of 20,000 mg/m3 might be encountered at sites where the vapor
source is gasoline or hydrocarbons dissolved in groundwater. A source vapor concentration  of
200,000 mg/m3 might be encountered at sites where the source is weathered gasoline NAPL just
above the water table. In both Figures 28 and 29, the source is located at a depth of 8 m bgs.
                                            66

-------
February 24, 2012                     Conceptual Model Scenarios of the Vapor Intrusion Pathway


The concentration profiles for the basement scenario (Figure 28) show that for source vapor
concentrations of 100,000 and 200,000 mg/m3 (representative of weathered gasoline NAPL
sources), oxygen is consumed before it can penetrate beneath the foundation. Thus, no
biodegradation is occurring beneath the foundation in the region below the 0.05 oxygen contour
line, because of limited oxygen availability and supply. In this region, the vapor transport is not
attenuated by biodegradation. As a result, the hydrocarbon concentration is higher below the
foundation compared with similar depths away from the building with sufficient oxygen for
biodegradation. For a source vapor concentration of 20,000 mg/m3, oxygen penetrates beneath
the entire foundation. The vapor transport is attenuated by biodegradation throughout much of
the subsurface, and the vertical profile of the hydrocarbon concentration is similar beneath the
building and away from the building.

The concentration profiles for the slab-on-grade scenario (Figure 29) show an increased oxygen
supply beneath the foundation relative to the basement scenario, and the vapor transport is
therefore attenuated by biodegradation beneath the entire building footprint, even for the highest
source concentrations simulated. The differences in the aerobic zone (oxygen) distribution
beneath the slab-on-grade foundation compared with the basement foundation are  due to the
combination of a smaller  distance for oxygen transport from the atmosphere and an increased
distance for hydrocarbon  transport from the source to locations immediately beneath the slab.
The concentration profiles in the subsurface away from the foundation are identical for both
scenarios (basement and slab-on-grade).

For the conditions simulated in Figures 28 and 29, the normalized indoor air concentrations (a)
decrease by about six orders of magnitude as the source vapor concentration decreases from
200,000 mg/m3 to 20,000 mg/m3 for both foundation types. The normalized indoor air
concentrations for the slab-on-grade foundation are about three orders of magnitude smaller than
those for the basement foundation. Biodegradation is influenced by the source vapor
concentration and may significantly decrease the soil vapor concentration and indoor air
concentration compared with the no biodegradation case (see Figure 7b).
                                           67

-------
February 24, 2012
Conceptual Model Scenarios of the Vapor Intrusion Pathway
Hydrocarbon
-1-
-
-3-
-4-
-5-
E^
a = 5.6E-ll\

H 1— -7
	 1 C.-I
^ 	 ^ 	
— 1E=3_
-Q-CL1
	 CLL


-8 ™ i I I i i
Hydrocarbon Sourc
-1-
•S- -2-
D) _g_
1 -4-
 ^^-^ ^^Vs — -t~— U»^_
.x^^^—LLj 	 ^ 	

I I I
6 8 10 1


2
                          Hydrocarbon Source Vapor Cone = 200,000 mg/m3

                         x (m)                                        x (m)

  Figure 28. Effect of source vapor concentration on hydrocarbon and oxygen distribution in soil
          gas and normalized indoor air concentration (a) for a building with basement.
  Hydrocarbon and oxygen concentration contour lines are normalized by source and atmospheric concentrations,
          respectively. The hydrocarbon vapor source is at 8 m bgs. Biodegradation rate (A) = 0.18 h"1.
                                    (Abreu and Johnson, 2006)
                                             68

-------
February 24, 2012
Conceptual Model Scenarios of the Vapor Intrusion Pathway
                         Hydrocarbon
                        Oxygen

1-
2-
4-
5-
6-
7-
]oc = 9.5E-14
1E-7


1E-6
1E-5
1E-4
1E-3
0.01
0.1
                                                                             DR
                                                       n     r
                            Hydrocarbon Source Vapor Cone = 20,000 mg/m3
£
(/)
D5
J3
i.
O)
Q

-1-
-2-
-3-
-4-
-5-
-6-
-7-
] a = 4.9E-ll \

— — — — li^L_
I3E6Z
ICC^
~^^ 1E-4
n^L -JE^
0.1
=^2=^^^==^^^^^^=
n Q 	 	 ^ —
i i i i i
                                                                                0.8
                                                                          _QJ_
                                                         l     l      l
                            Hydrocarbon Source Vapor Cone = 100,000 mg/m3
  6     8    10    12  6     2    4     6     8
Hydrocarbon Source Vapor Cone = 200,000 mg/m3
                                                                               i
                                                                               10
                                             12
                          x(m)
                            x(m)
  Figure 29. Effect of source vapor concentration on hydrocarbon and oxygen distribution in soil
          gas and normalized indoor air concentration (a) for a slab-on-grade building.
  Hydrocarbon and oxygen concentration contour lines are normalized by source and atmospheric concentrations,
          respectively. The hydrocarbon vapor source is at 8 m bgs. Biodegradation rate (A) = 0.18 h"1.
                                    (Abreu and Johnson, 2006)
                                              69

-------
February 24, 2012
                      Conceptual Model Scenarios of the Vapor Intrusion Pathway
Normalized indoor air concentrations for a broader range of source concentrations, depths, and
biodegradation rates (?i) are presented in Figure 30 for a basement scenario. Plots are presented
for two source depths, 3 and 8 m bgs. The plot shows a family of curves with similar shapes and
trends of decreasing normalized indoor air concentrations with a decreasing source vapor
concentration, an increasing biodegradation rate, and an increasing source depth. For source
vapor concentrations less than 10,000 mg/m3, biodegradation occurs without oxygen limitations
throughout the subsurface and normalized indoor air concentrations are relatively unaffected by
changes in the source vapor concentration. For source vapor concentrations above 10,000 mg/m3,
normalized indoor air concentrations increase with increasing source vapor concentration, until
they reach the value for the case of sub-slab oxygen depletion (when biodegradation beneath the
foundation ceases), after which the results of the simulations are similar to those for chemicals
that do not readily biodegrade aerobically (i.e., recalcitrant compounds). Increasing
biodegradation rates generally correspond to decreasing normalized indoor air concentrations,
except where oxygen depletion and anaerobic conditions occur beneath the foundation (i.e., at
high vapor source concentrations), because aerobic biodegradation stops when oxygen is not
present.
             a
1.E-02 i


1.E-04 •


1.E-06


1.E-08


1.E-10


1.E-12


1.E-14


1.E-16


1.E-18


1.E-20


1.E-22
                                        10                 100
                                     Source Vapor Concentration (mg/L)
                                                                            1000
                          •Sources m bgs, No Biodegradation
                          -Sources m bgs, A= 0.018 (1/h)
                          -Sources m bgs, A = 0.18 (1/h)
                          -Sources m bgs, A = 1.8 (1/h)
                                  —A— Source 8 m bgs, A = 0.018 (1 /h)
                                  —»— Sources m bgs, A = 0.18 (1/h)
                                  —B—Sources m bgs, A = 1.8 (1/h)
      Figure 30. Relationship between source vapor concentration and normalized indoor air
    concentration (a) for three biodegradation rates (A), two source depths and a building with
                                         basement.
                                   (Abreu and Johnson, 2006)
                                             70

-------
February 24, 2012
                           Conceptual Model Scenarios of the Vapor Intrusion Pathway
For the same conditions of source concentration, biodegradation rate, and source depth, the
normalized indoor air concentration for a slab-on-grade foundation (Figure 31) may be several
orders of magnitude lower than the normalized indoor air concentrations for a basement
foundation, because of the larger foundation-source separation for slab-on-grade buildings and
the rapid rate of biodegradation relative to the rate of transport.

The plot for the no biodegradation case in Figures 30 and 31 shows that the normalized indoor
air concentrations for recalcitrant compounds that do not readily biodegrade aerobically are
independent of source concentration. The plots also show that biodegradation may reduce the
normalized indoor air concentrations by many orders of magnitude compared with the no
biodegradation case. This is a key difference between biodegradable and recalcitrant compounds.
      a
1.E-02

1.E-04

1.E-06

1.E-08 '

1.E-10

1.E-12

1.E-14

1.E-16

1.E-18

1.E-20

1.E-22 i

1.E-24

1.E-26
                        •      ""       .£>-
                        7)	«.	•**
Q.
                                     .0.
                                    -B'
                  1
                           10                    100
                         Source Vapor Concentration (mg/L)
                                                         1000
                    •Sources m bgs, No Biodegradation
                    • Source 3 m bgs, A = 0.018 (1 /h)
                    •Source3m bgs, A = 0.18 (1/h)
                    - Source 3 m bgs, A = 1.8 (1 /h)
                                      —A-- Source 8 m bgs, A = 0.018 (1 /h)
                                      —&— Sources m bgs, A = 0.18 (1/h)
                                      —B— Source 8 m bgs, A = 1.8 (1/h)
      Figure 31. Relationship between source vapor concentration and normalized indoor air
   concentration (a) for three biodegradation rates (A), two source depths and a slab-on-grade
                                          building.
                                   (Abreu and Johnson, 2006)
                                            71

-------
February 24, 2012                       Conceptual Model Scenarios of the Vapor Intrusion Pathway
5.2    Source Depth
  The figures in this section illustrate the effect of vertical separation distance between the source and the building
  foundation on the distribution of biodegradable hydrocarbon vapors in the subsurface. Because the foundation
  slab inhibits downward diffusion of oxygen, fora given foundation area, degradation is likely to be more complete
  in settings where the separation between the source and the base of the foundation is greater and the source
  concentrations are smaller (Figure 32). Plots of normalized indoor air concentrations for a variety of conditions at
  a structure with a basement and one with a slab-on-grade are depicted in Figures 33 and 34, respectively. (For
  comparisons with scenarios where the VOCs are recalcitrant, see Figures 7b and 8.)
The effect of source depth on the soil vapor concentration distribution profile for biodegradable
hydrocarbons is illustrated in Figure 32 for a slab-on-grade foundation, two source vapor
concentrations (2,000 and 200,000 mg/m3), and two source depths (3  and 8 m bgs). As illustrated
in Figure 32, for a shallow source with a concentration representative of a weathered gasoline
NAPL source, oxygen is depleted before reaching the subsurface beneath the building. Thus,
because of oxygen limitations, little or no biodegradation is expected  to occur beneath the slab.
This scenario was observed  in a field study conducted by Patterson and Davis (2009). As the
source depth increases, oxygen fully penetrates below the foundation, and aerobic
biodegradation reduces the soil vapor concentration by four orders of magnitude compared with
the no biodegradation case (previously depicted in Figure 8). For a lower vapor concentration
source, potentially representative of a dissolved groundwater source, oxygen concentrations in
the entire subsurface are sufficient to allow biodegradation and reduce the soil vapor
concentration by many orders of magnitude compared with the no biodegradation case.

For the conditions simulated in Figure 32, as the vapor source depth increases from 3  to 8 m (less
than a factor of 3), the normalized indoor air concentration (a) decreases by about six orders of
magnitude (a factor of 1,000,000) for the lower concentration scenario and by about four orders
of magnitude (a factor of 10,000) for the higher concentration scenario. By comparison, the
normalized indoor air concentration for the no biodegradation case presented in Figure 8
decreases by less than  a factor of two as the source  depth increases by 10m.

Normalized indoor air concentrations for a broader set of source depths and biodegradation rates
are presented in Figures 33  and 34 for a basement and slab-on-grade  scenarios, respectively.
These figures show a family of curves with similar  shapes and trends  of decreasing normalized
indoor air concentrations with increasing source depth. Increasing biodegradation rates generally
correspond to decreasing normalized indoor air concentrations, except for shallow, high-
concentration sources, where oxygen depletion and anaerobic conditions occur beneath the
foundation, and biodegradation is stifled. These simulations indicate a decrease of multiple
orders of magnitude in the normalized indoor air concentrations with  an increase in source depth
of approximately 2 m.  The plots also show that biodegradation may reduce the normalized
indoor air concentrations by six orders of magnitude compared with the no biodegradation case.
                                             72

-------
February 24, 2012
                             Conceptual Model Scenarios of the Vapor Intrusion Pathway
                          Hydrocarbon                             Oxygen


                            Hydrocarbon Source Vapor Cone = 2,000 mg/m3


2-

1 a = 3.9E-7
_^£_^

^^£-4—
0 01
0 1
I I I I I
                                         Vapor Source 3 m bgs
                0
               -2-


               -4-


               -6-
                      = 9.5E-14
                               1E-7
                      1E-5
                          1F-fi
                  1E-4
              1E-3
                        001
                      01
                                                    \s////////////
i
0
Q
                                         Vapor Source 8 m bgs


                            Hydrocarbon Source Vapor Cone = 200,000 mg/m3
                ^
                                         Vapor Source 3 m bgs
                                                                             -03-
                                 x(m)
                                       8    10   12  0     2
                                         Vapor Source 8 m bgs
                                                              8    10    12
      Figure 32. Effect of source depth and vapor concentration on hydrocarbon and oxygen
  distribution in soil gas and normalized indoor air concentration (a) for a slab-on-grade building.
  Hydrocarbon and oxygen concentration contour lines are normalized by source and atmospheric concentrations,
          respectively. The hydrocarbon vapor source is at 8 m bgs. Biodegradation rate (A) = 0.18 h"1.
                                               73

-------
February 24, 2012
Conceptual Model Scenarios of the Vapor Intrusion Pathway
         1.E-02
         1.E-03
         1.E-04
         1.E-05
    a    1.E-06
         1.E-07
         1.E-08
         1.E-09
         1.E-10
               0    1    2   3    4   5    6    7   8    9   10  11  12   13  14   15   16
                                     Depth of Vapor Source bgs(m)
    	No Biodegradation
    •-A--- Source cone = 2 mg/L, A = 0.018 (1/h)
     -O  - Source cone = 2 mg/L, A = 0.18 (1/h)
     -D-  - Source cone = 2 mg/L, A = 1.8 (1/h)
             -Source cone = 200 mg/L, A = 0.018  (1/h)
             -Source cone = 200 mg/L, A = 0.18  (1/h)
             -Source cone = 200 mg/L, A = 1.8 (1/h)
  Figure 33. Relationship between source depth and normalized indoor air concentration (a) for a
  building with basement, two source vapor concentrations, and three biodegradation rates (A).
                                   (Abreu and Johnson, 2006)
                                             74

-------
February 24, 2012
Conceptual Model Scenarios of the Vapor Intrusion Pathway
        1.E-02
        1.E-03
        1.E-04
        1.E-05
        1.E-06
        1.E-07
        1.E-08
        1.E-09
        1.E-
               0    1    2   3    4   5   6    7   8    9   10  11  12   13  14   15  16
                                     Depth of Vapor Source bgs (m)
     	No Biodegradation
      -A- - Source cone = 2 mg/L, A = 0.018  (1/h)
      -O - Source cone = 2 mg/L, A = 0.18 (1/h)
      -D- - Source cone = 2 mg/L, A = 1.8 (1/h)
              -Source cone = 200 mg/L, A = 0.018 (1/h)
              -Source cone = 200 mg/L, A = 0.18 (1/h)
              -Source cone = 200 mg/L, A = 1.8 (1/h)
  Figure 34. Relationship between source depth and normalized indoor air concentration (a) for a
   slab-on-grade building, two source vapor concentrations, and three biodegradation rates (A).
                                   (Abreu and Johnson, 2006)
                                             75

-------
February 24, 2012                       Conceptual Model Scenarios of the Vapor Intrusion Pathway
5.3    Source Lateral Distance from Building
  The figures in this section illustrate how the source depth and location influence soil vapor and indoor air
  contaminant concentrations for very concentrated (i.e., NAPL) biodegradable sources. Because the foundation
  slab inhibits downward diffusion of oxygen, biodegradation is likely to be more complete at settings where there is
  a lateral separation between the NAPL source and the base of the foundation than at settings where the NAPL
  source is below the foundation (Figure 35). Plots of normalized indoor air concentrations for a variety of
  conditions at a structure with a basement and a NAPL source are depicted in Figure 36. (For comparisons with
  scenarios where the VOCs are recalcitrant, see Figures 9 through 11.)
The effect of source-building lateral distance for aerobically biodegradable chemicals is
illustrated in Figure 35 for the basement scenario, a source vapor concentration representative of
a weathered gasoline NAPL  source (200 mg/L), two source depths (3 and 8 m bgs), and two
lateral source-building separations (a source directly beneath the building basement on the left,
and a source 5 m away from  the edge of the building basement, on the right).  The profiles show
that a relatively small source-building lateral separation can result in a very large reduction in the
normalized indoor air concentrations (a) for both shallow and deep sources, provided that the
ground surface is open to allow oxygen to enter the subsurface.

Normalized indoor air concentrations for a broader set of source-building lateral distances and
biodegradation rates are presented in Figure 36 for the basement scenario, a source vapor
concentration of 200 mg/L, and two source depths (3 and 8 m bgs). Figure 36 shows that the
normalized indoor air concentrations decrease with increasing lateral distance and increasing
biodegradation rates. If the source (or part of it) lies beneath the building (i.e., the source edge-
building center lateral separation ranges from -15 to 5 m in Figure 36), normalized indoor air
concentrations are relatively  unaffected by the location of the source edge, but as the lateral
distance increases and the source edge is no longer beneath the foundation (i.e., the source edge-
building center lateral separation is >5 m), the effect of biodegradation may result in a large
reduction in the normalized indoor air concentrations for both the shallow and deep sources at
high concentrations representative of a weathered gasoline NAPL source, provided that the
ground surface is open to supply oxygen to the subsurface. Figure 36 also shows that
biodegradation may reduce the normalized indoor air concentrations by ten or more orders of
magnitude compared with the no biodegradation case.
                                             76

-------
February 24, 2012
Conceptual Model Scenarios of the Vapor Intrusion Pathway
                                     Shallow Hydrocarbon Vapor Source
                                              Hydrocarbon
 Q.

 Q









X3=^


nm
=L^
	 =\
0

^=3R.
^^lf
\05 Will

9

^
                                                Oxygen
                                       Deep Hydrocarbon Vapor Source
                                             Hydrocarbon         ^
                                                Oxygen

-2-
-4-
-b-

^IMI-
0.5 ^^ 0.5
\
f§
///IP55 °2i\i
IT if


\
\

T

-




n^
^
^-/////////^



]

f "^ -"" — — ~~~~ "
1 -C-— 	 ^^X\



i£^^i
IT
\
\ \
\\
\ \ \
\
T
     10   20    30   40    50   60    70   80    9010    20    30   40    50   60    70   80    90
                                                 x(m)

      Figure 35. Effect of source depth and source-building lateral separation distance on the
              distribution of hydrocarbon and oxygen in soil gas for a NAPL source
  Hydrocarbon and oxygen concentration contour lines are normalized by source and atmospheric concentrations,
     respectively. The source vapor concentration is 200 mg/L at two groundwater depth (3 m and 8 m). a is the
           normalized indoor air concentration (basement scenario). Biodegradation rate (A) = 0.18 h"1.
                                           (Abreu, 2005)
                                               77

-------
February 24, 2012
Conceptual Model Scenarios of the Vapor Intrusion Pathway
          1.E-02
          1.E-03
          1.E-04
          1.E-05
     Ot   1.E-06
          1.E-07
          1.E-08
          1.E-09
          1.E-10
                                                       source zone no longer
                    source size 30 m x 30 m
                -15       -10       -50        5       10       15
                               Source Edge -Building Center Separation (m)
                     • Source 3 m bgs, no biodegradation
                     -Source 3 m bgs , A= 0.018 (1/h)
                     -Source 3 m bgs , A=0.18 (1/h)
                     -Source 3m bgs  ,A=1.8(1/h)
             — ——  Source 8m bgs, no biodegradation
             . _A- - Source 8m bgs , A= 0.018 (1/h)
             - -O- - Source 8m bgs , A= 0.18 (1/h)
             - -D- - Source 8m bgs , A= 1.8 (1/h)
   Figure 36. Relationship between source-building lateral separation distance and normalized
              indoor air concentration (a) for a NAPL source, two source depths, and
                                 three biodegradation rates (A).
The source-building lateral separation is measured from the edge of the source zone to the center of the building with
  a basement; negative values and values <5 m indicate that the source is to some extent beneath the building. The
                               source vapor concentration is 200 mg/L.
                                          (Abreu, 2005)
                                               78

-------
February 24, 2012                       Conceptual Model Scenarios of the Vapor Intrusion Pathway
5.4    Moisture Content in Layered Soil
  The figures in this section use a single-building scenario to illustrate how nonhomogeneous soils (i.e., soils with
  layers of higher and lower moisture and associated soil gas permeability) can impact oxygen penetration and
  biodegradable hydrocarbon concentrations in soil gas in the vicinity of a building. The impact of the layers on the
  hydrocarbon and oxygen distributions depends on their location relative to the source and the building foundation,
  as well as the source strength. The degree of oxygen penetration also depends on whether the building is under-
  pressurized or over-pressurized. Figure 37 depicts conditions with different soil configurations and a weathered
  NAPL source. Figure 38 depicts conditions with low permeability materials at the ground surface for both a
  weathered NAPL source and a dissolved groundwater source. (For comparisons with scenarios where the VOCs
  are recalcitrant, see Figures 19 and 20.)
This section presents simulations illustrating the predicted effect of soil moisture content
distribution on vapor transport and indoor air concentrations of aerobically biodegradable
compounds for scenarios with a single building and a uniform vapor source at groundwater level
(8 m bgs). The simulations were performed for buildings under- and over-pressurized to evaluate
the predicted effect of steady air flow into and out of the building. The conceptual model
scenarios simulated are the same as those presented in Figure 19a, and the predicted pressure
field and soil gas flow rate (Qs) are the same as those presented in Figure 19b. As previously
discussed, the moisture content in the soil affects vapor transport by diffusion (the diffusion
coefficients decrease with increased moisture content) and may also affect advective transport
because of lower permeability in higher moisture content soils. Moisture content of the soil will
similarly affect the downward migration of oxygen from the atmosphere into the subsurface.

Figure 37 presents the soil vapor concentration profiles and indoor air concentrations predicted
for a source strength representative of a weathered gasoline NAPL source (200,000 mg/m3)
vapor concentration (Johnson et al.,  1990). For the homogeneous scenario (Scenario A), oxygen
is depleted below the slab for both building pressurization conditions, and the hydrocarbon
concentrations beneath the slab are not reduced by biodegradation. In Scenario B, with high-
moisture content layers between the source and the foundation and a low-moisture content layer
extending from the ground surface down to below the foundation, the contaminant migration
toward the foundation is reduced and the oxygen supply beneath the slab is sufficient to promote
biodegradation for both building pressurization conditions. In Scenario C, with high-moisture
content layers between the source and the foundation and a high-moisture layer at the ground
surface, oxygen is depleted below the foundation when the building is under-pressurized, but
when the building is over-pressurized, the oxygen supply beneath the slab is sufficient to allow
biodegradation.  In Scenario D, with a high-moisture layer at the ground surface and a low-
moisture content layer in the remaining subsurface, oxygen is depleted throughout the subsurface
and no aerobic biodegradation is predicted to occur.
                                             79

-------
February 24, 2012
                                                                    Conceptual Model Scenarios of the Vapor Intrusion Pathway
                                    Builcing Underpressurisd 5 Pa
                                                                                    B tiding Owerpressureed 5 Pa
                          Hydrocarbon
                                      Oxygen
Hydrocarbon
                                                                                                       Oxygen
Soil layers
      High permeability: per cent saturation (S) =20%; soil gas permeability (Kg) = 1E-11 m
permeability: S = 60%, Kg = 1E-13 m2.
                                                                                                Low
       Figure 37. Effect of layered soils (rows A-D) on hydrocarbon and oxygen distribution in soil gas and normalized indoor air
                                    concentration (a) for two building pressures (basement scenario).
 Hydrocarbon and oxygen concentration contour lines are normalized by source and atmospheric concentrations, respectively. The source vapor concentration is
                                           200 mg/L located 8 m bgs. Biodegradation rate (A) = 0.18 h"1.
                                                                    80

-------
February 24, 2012
Conceptual Model Scenarios of the Vapor Intrusion Pathway
Note that the source concentration in Figure 37 is representative of weathered gasoline NAPL,
which was used here to illustrate the regions of oxygen depletion. For dissolved groundwater
sources (with lower source concentration), it is likely that the oxygen supply in the subsurface
would be sufficient to allow biodegradation in most scenarios, provided that the soil above the
source is clean (i.e., does not contain residual  NAPL or any other second source of hydrocarbons
that could deplete oxygen) and there are no physical or geologic barriers to oxygen entry to the
subsurface. This conclusion generally agrees with the findings from field data analysis by Davis
(2009). Figure 38 illustrates the profiles predicted for a weathered gasoline NAPL source
(200 mg/L vapor concentration) and for a dissolved groundwater source (2 mg/L vapor
concentration), assuming Scenario D with a high moisture content layer on the ground surface
and the building under-pressurized by 5 Pa. The predicted concentration profiles and normalized
indoor air concentrations (a) show that, for the lower concentration source, there is sufficient
oxygen in the subsurface,  such that aerobic biodegradation reduces the contaminant
concentration by nine orders of magnitude.
                    Hydrocarbon
                    Oxygen
                                                                                Soil layers
      -2
      -4-
      -6-
      -8-
  O)
  .Q
  o>
             = 7.1E-15x
                        1E-7
                        1E-5
                        1E-3
                         0.1
                                                                        0.9
                     Hydrocarbon Source Vapor Cone = 2,000 mg/rtr
      -2
      -6-
                                                                   0.05
        0     2     4     6     8     10    120     2     4     6     8    10    12
                       Hydrocarbon Source Vapor Cone = 200,000 mg/m3

                      x (m)                                     x (m)

  Figure 38. Effect of source vapor concentration on hydrocarbon and oxygen distribution in soil
  gas and normalized indoor air concentration (a) for scenarios with low permeability soils at the
                ground surface (e.g., soil layer scenario on row D of Figure 37).
  Hydrocarbon and oxygen concentration contour lines are normalized by source and atmospheric concentrations,
         respectively. Source located at 8 m bgs (basement scenario). Biodegradation rate (A) = 0.18 h"1.
                                            81

-------
February 24, 2012                       Conceptual Model Scenarios of the Vapor Intrusion Pathway


5.5    Geologic Barrier
  The simulations in this section further illustrate how nonhomogeneous soil conditions can impact biodegradable
  hydrocarbon concentrations in soil gas. These simulations expand on the concepts in Section 5.4. by depicting
  the influence of low permeability soil layers that can act as "barriers" to gas migration (which are modeled here as
  soil layers with 95% pore water saturation) over a broad range of soil layering profiles for a vapor source at
  groundwater table at 5 m bgs and a building with a basement. The simulations illustrate that,  depending on the
  location of the barrier relative to the source and the foundation, up to several orders of magnitude decrease in
  concentrations can occur between the area beneath a geologic soil barrier and the area above it for NAPL
  sources (Figure 39). They also illustrate that, despite the presence of a barrier, enough oxygen may penetrate
  the subsurface to effectively diminish the concentration of degradable VOCs in settings where the source strength
  concentrations are in the dissolved phase range (Figure 40). (For comparisons with scenarios where the VOCs
  are recalcitrant, see Figure 25.)
As illustrated in Section 4.4.4 for recalcitrant chemicals, a low permeability geologic barrier may
reduce the soil vapor concentration above it by at least one order of magnitude. This section
examines the effect of geologic barriers for aerobically biodegradable compounds. The same
conceptual models presented in Figure 25 are used in the simulations presented in this section
(e.g., the barrier layer is assumed to be at 95% water saturation). As noted in Section 4.4.4, the
particular properties assumed for the barriers in these simulations may or may  not be typical of
most sites but will serve to illustrate how a low permeability soil layer can influence the
distribution of VOC concentrations in the subsurface and indoor air.

The source vapor concentration has a substantial effect on the predicted concentration profile of
aerobically biodegradable chemicals. Therefore, simulations are presented here for two source
types: a NAPL source with 200 mg/L vapor concentration and a dissolved groundwater source
with a 2 mg/L vapor concentration. The predicted hydrocarbon and oxygen concentration
profiles and normalized indoor air concentrations (a) are presented in Figure 39 for the NAPL
source and Figure 40 for the dissolved groundwater source. The profiles  suggest that, compared
with homogeneous subsurface conditions, a geologic barrier may reduce the soil vapor
concentration above it by many orders of magnitude for aerobically biodegradable hydrocarbons,
provided that sufficient oxygen is present in the subsurface.

The results presented in Figure 39 for the weathered gasoline NAPL source show that in
Scenario B, where the geologic barrier extends below the foundation,  the normalized indoor air
concentration is reduced by more than three orders of magnitude compared with the
homogeneous case, because oxygen penetrates entirely below the foundation, allowing
biodegradation and reducing the hydrocarbon concentration. For scenarios where the geologic
barrier does not extend  below the foundation (Scenarios C and D),  oxygen is depleted below the
foundation, no aerobic biodegradation is occurring there, and the predicted normalized indoor air
concentrations are similar to the homogeneous case. The results presented in Figure 40 for the
dissolved groundwater  source show that predicted oxygen concentrations are elevated for all
scenarios and that aerobic biodegradation reduces the vapor concentration in the subsurface and
indoor air by many orders of magnitude, regardless of the location  of the  geologic barrier and
how it extends beneath  the foundation.
                                             82

-------
February 24, 2012
                                                                           Conceptual Model Scenarios of the Vapor Intrusion Pathway
           Conceptual scenarios and Predicted Qs
                                                                        Soil Vapor Concentration Distribution and a
                                                                Hydrocarbon                              Oxygen
   -1-
   -3-
   -4-
   -5
       Qs = 3.7 L/min \
              vapor source
 CL
 =—-;
                                                                                                                         10    12    14    16
                                                                             10    12    14    160    2468
                                                                             x(m)
    I   I  High permeability: percent saturation (S) = 20%; soil gas permeability (Kg) = 1E-11  m2
    HI Low permeability barrier: S = 95%, Kg = 1E-13 m2.
Figure 39. Effect of geologic barriers on hydrocarbon and oxygen distribution in soil gas and normalized indoor air concentration (a) for
                                                         a NAPL source at 5m bgs.
 Hydrocarbon and oxygen concentration contour lines are normalized by source and atmospheric concentrations, respectively. Source vapor concentration is 200
           mg/L (basement scenario). Biodegradation  rate (A) = 0.18 h"1. Qs is the soil gas flow rate predicted for building under-pressurized by 5 Pa.
                                                              (Abreuetal., 2006)
                                                                     83

-------
February 24, 2012
                    Conceptual Model Scenarios of the Vapor Intrusion Pathway
          Conceptual scenarios and Predicted Qs
        Soil Vapor Concentration Distribution and a
Hydrocarbon                                 Oxygen
u-
-1-

-2-


-4-
-5H
-1-

-2-
E- ^
D)
'S. 1
S

-3-

-4-
0-
-1-

-2-
_3

-4-
(
— '-i
	 3-|
Qs = 3.7 L/min




B
=^l
Qs = 2.0 L/min


C
^
Qs = 2.2 L/min




D

Qs = 2.1 L/min




) 2 4









\























vapor source




vapor source




^^^^^^^^^^^ ^^^^^^
^^^^^^^^^^1 ^^^^^H
vapor source






vapor source
6 8 10 12 14 1











-






—







6
— l~i
1
a=1.3E-7
1




=^1
a=1.4E-15
1E-7
0.1
I |
^
a = 4.7E-8
1E
1E-3

0.1
I |
~^
a = 5.7E-8
1



324
I
[

c











A











1E-7

1E-S
I
1E=3

0.1
I I I I ^^^
^J£-7^
^jiir^

-------
February 24, 2012                      Conceptual Model Scenarios of the Vapor Intrusion Pathway
6.0   Temporal and Spatial Variability in Subsurface and  Indoor Air
       Concentrations
  The figures in this section depict scenarios that illustrate possible temporal and spatial changes in the distribution
  of VOCs and the factors that can lead to those changes.
This section discusses the temporal and spatial variability that may occur in the subsurface, sub-
slab, and indoor air concentrations caused by several factors: transient transport after a source is
released, wind load on a building, fluctuations in atmospheric and indoor air pressures, and
seasonal phenomena (e.g., rainfall events, fluctuation on water table elevation). Other conditions
that result in spatial variability, such as sources located laterally away from buildings and
discontinuous layers, have already been illustrated in previous sections.

6.1    Transient Transport Following Source Release

The simulations presented thus far assume that the vapor source has been in place long enough to
fully develop the soil gas profiles (or reach near-steady-state conditions). Johnson et al. (1999)
developed a simplified equation to estimate the time necessary to achieve near-steady-state
subsurface vapor distributions and estimated that sites with shallow vapor sources (<1 m depth)
take only a few hours to a few days to reach near-steady-state conditions.  Sites with deeper
vapor sources (>10 m depth) may take months or years to reach steady-state conditions. Aerobic
biodegradation may reduce the time to reach steady-state soil gas distributions because once the
VOCs are degraded, their migration path is shorter to the point that VOC concentrations are
reduced substantially.

The time required for vapors to reach near-steady concentrations at any location in the
subsurface increases with the square of the distance  from the source. It is also affected by the
chemical properties of the  compound of interest. Johnson et al. (1999) developed a graph that
provides the time for a non-retarded chemical to reach near-steady vapor concentrations (TSS/RV)
as a function of soil type and distance to the source (Figure 41). This graph can be used for any
chemical, and the retardation time for any specific chemical can be calculated by multiplying
TSS/RV by the chemical retardation factor (Rv), which is calculated as follows:
                                                                                      (i)
                                       n       <>Sn
where
     (|)w  =  water-filled porosity (m3 water/m3 soil)
     (|)g  =  gas-filled porosity (m3 gas/m3 soil)
     Pb  =  soil bulk density (kg soil/m3 soil)
     Hn  =  Henry's law constant for chemical n ([kg chemical/m3 gas]/[kg chemical/m3 water])
   Koc,n  =  sorption coefficient of chemical n to organic carbon ([kg chemical/kg OC]/[kg
            chemical/m3 water])
     foc  =  mass fraction of organic carbon in the soil (kg OC/kg soil).
                                           85

-------
February 24, 2012
Conceptual Model Scenarios of the Vapor Intrusion Pathway
                  10000
                   1000
            [d]
                    100
                     10
           medium sands

          fine sands
         silty sands
         clayey silts
         clays
                         0
    10
15
20
25
30
                                 Distance from Source [m]
       Figure 41. Estimated time (y-axis, d=days) for chemicals to reach near-steady vapor
concentrations (TSS) as a function of the distance from a source. Time on the plot is normalized by
                                the retardation factor (Rv).
                                   (Johnson et al., 1999)

The sub-sections below provide examples illustrating the variation in concentration profiles with
time following the release of the vapor source. The effect of moisture content and distribution on
transient profiles is presented first, followed by an example illustrating how sorption of the
VOCs to soil organic carbon (foe) attenuates the VOCs in the subsurface.
                                           86

-------
February 24, 2012                       Conceptual Model Scenarios of the Vapor Intrusion Pathway


6.1.1  Effect of Moisture Content on Transient Transport
  The figures in this section illustrate how the moisture content of the soils may impact VOC distributions through
  time after a source is released and vapors migrate beneath a structure. They include simulations where the
  groundwater vapor source is 8 m below the surface (Figure 42) and where it is 3 m below the surface (Figure
  43). They also include simulations with a variety of layered soils and multiple building distances from the source
  (Figure 44). Areas closer to the source achieve near-steady conditions sooner than those farther away. Drier
  soils achieve near-steady conditions more quickly than soils with higher moisture content. Soil layers with higher
  moisture content can delay attainment of near-steady conditions in soils above them.
The effect of soil moisture content on the transient concentration profiles in the subsurface is
described here for recalcitrant vapor sources located at groundwater level. In this case, the vapor
migration may occur upwards toward the ground surface or laterally to regions of lower
concentration. Simple scenarios involving a single building with a basement and a large source
directly beneath the building illustrate the transient upward migration of vapors. Two
homogeneous soils with pore water saturations (S) of 20% and 60% and two source depths (3 m
and 8 m bgs) were used in the simulations. In all scenarios, the buildings were assumed to be at
constant atmospheric pressure conditions and, as a result, the transport is due to diffusion only.

The results presented in Figure 42 are for an  8 m deep vapor source and show the concentrations
at three transport times after the source is released: 1 month, 1 year, and 3 years. In Scenario A,
with a lower soil moisture content, the concentrations reach near-steady-state conditions about 1
year after the source release. In Scenario B, the higher soil moisture content leads to a
concentration below the  slab after 1 year that is more than an order of magnitude lower than in
Scenario A. It takes about 9 years for Scenario B to reach steady state.

The results presented in Figure 43 for a shallow vapor source show that the transport time is
shorter if the source is shallow, and it may take just days or a few months to reach steady state.
This is consistent with the time frames described by Johnson et al. (1999).
                                             87

-------
February 24, 2012
Conceptual Model Scenarios of the Vapor Intrusion Pathway
Scenario A Scenario B
Pore water saturation = 20% 1 month Pore water saturation = 60%

-
-4
-8
n

g
(T)
E5 -4
it
0 -6-
-8
o

-4
-6
s





.U 1
0.1
0.2
0 3



P
— S
a = 3.3E-5\
0.5
-
1 P^J
1 yea
0.1
-4X2
— Q-3_
MX4_
~~~~_____^
—-- — 	 	



^i
a-3.8E 5 \
0.6 \
JLl



-
3 yes
0 1

.2
D 5~~*"^~
""~— — - _— 	
^~~— — — 	 	
~~- — - — __________


v


-
^ \
a = 8.0E-21\.

-1 C 7
1 1^~ /



0 01
01
i i i i i
r
— H
a = 4.3E-7 \

1F-3

0.01
0.1
02
0.3

irs
	 i
a =9.0E-6 \

n 1
_JL.T
	 QJJ^







             0     2     4     6     8     10    12 0     2     4     6     8     10    12
      Figure 42. Effect of transport time on soil vapor distribution and normalized indoor air
         concentration (a) for different soil pore water saturation (deep source, 8 m bgs).
 The soil vapor concentration contour lines are normalized by the source vapor concentration. The building is under
                                      atmospheric pressure.
                                              88

-------
February 24, 2012
                                  Conceptual Model Scenarios of the Vapor Intrusion Pathway
 en
Q
 0-


-2
-3
                     Scenario A
               Pore water saturation = 20%
                                               1 d
                                                            Scenario B
                                                     Pore water saturation = 60%

1

-2

-1-

— H
^^
r/ S OTn ^
(X — J.UC 0

a-6.3E 5
0 9










^ o.i °'01
i
1
0.1





we<


	 s
^^


^^~
;k
a - 7.5R-7











^ 1E-7
I I '
1F-7
i
                                              6 months
                                     n?
                             -QJ
                                         10
      Figure 43. Effect of transport time on soil vapor distribution and normalized indoor air
        concentration (a) for different soil pore water saturation (shallow source, 3 m bgs).
   The soil vapor concentration contour lines are normalized by the source vapor concentration. The building is at
                                      atmospheric pressure.
                                             89

-------
February 24, 2012                      Conceptual Model Scenarios of the Vapor Intrusion Pathway


More complex scenarios with multiple buildings and a finite source are presented in Figure 44
and illustrate the transient upward and lateral migration of vapors. Two scenarios are presented
for comparison: Scenario lisa homogeneous subsurface with low moisture content and Scenario
2 is a layered subsurface with soil properties as shown in the figure. A vapor source is located at
8 m bgs and extends up to 25 m laterally. Each scenario has three slab-on-grade buildings.
Building A has no cracks or openings in the foundation and is located above the vapor source;
Buildings B and C have full-length perimeter cracks and are located 5 and 25  m laterally from
the source edge, respectively. The buildings are assumed to be at steady atmospheric pressure,
and the transport is due to diffusion only.

Figure 44 illustrates the profiles for three transport times after the source is released: 1 month, 1
year, and 3 years. In both scenarios, the concentration close to the source reaches near-steady-
state conditions much faster than the concentration farther away from the source. The higher
moisture content layer in Scenario 2 affects the soil vapor concentration distribution and
increases the transport time. The farther the building is from the vapor source, the longer it takes
for the vapor to reach it, and the time increases as the moisture content of the  subsurface
increases.
                                            90

-------
February 24, 2012
   Conceptual Model Scenarios of the Vapor Intrusion Pathway
                       Scenario 1: Homogeneous Subsurface
Scenario 2: Layered Subsurface
                                                                                                          Soil layers


1 -2-

D)
-Q .4-
'S.
Q ~6~
-8-
HA
'

^^^^s
____-^- 	 -\
	 	 	
Vapor Source


0.1
\, \
"x
^ 1
, r



\
\
1


RB








i1 \
\





\




n

>




c








>







-i


T
                                                                                                               1 month
                        10     20     30     40     50     60
                                                            70    0
                                                              x (m)
                     Percentage of water in soil pore (S) = 20%       S = 60%
                                                                                                                1 year
                                                                                                                3 years
                                                                       10     20     30     40     50     60
 Figure 44. Effect of transport times on soil vapor distribution for scenarios with homogeneous lithology and layered soils, and multiple
                                             buildings over spatially finite vapor source.
                            The soil vapor concentration contour lines are normalized by the source vapor concentration.
                                                                91

-------
February 24, 2012                       Conceptual Model Scenarios of the Vapor Intrusion Pathway


6.1.2  Effect of Sorption on Transient Transport
  The figures in this section illustrate the effect of soil sorption on the estimated time that vapor concentrations take
  to reach a near-steady condition after a source is released and vapors migrate beneath a structure (i.e., transient
  transport) for two different sorption scenarios (Figure 45). Soils with higher organic carbon content (foe) and
  contaminants with higher organic carbon-water partitioning coefficients (Koc) tend to sorb more and, therefore,
  delay attainment of near-steady conditions.
For transient transport conditions, the mass fraction of organic carbon in soil (foe) and a
chemical's sorption coefficient to organic carbon (Koc) determine the amount of the chemical
that is adsorbed to the soil particles, which retards chemical transport.

The effects of foe and Koc on the soil vapor concentration distribution under transient transport
conditions are illustrated in Figure 45. Two scenarios, A and B, are presented for comparison:
both include a homogeneous subsurface, but Scenario B has higher foe and Koc values than
Scenario A, as shown in the figure. The vapor source of recalcitrant VOC is located beneath the
foundation at a depth of 8 m bgs. The scenarios illustrate two buildings with a basement, both of
which have full-length perimeter cracks and are at atmospheric pressure conditions, so the
transport in the subsurface is due to diffusion.

Figure 45 illustrates the concentration profiles for three transport times after the source is
released: 1 month, 1 year, and 3 years. The substantial difference in soil vapor concentration
distribution between Scenarios A and B illustrates the strong influence that foe and Koc have on
the transient concentration distribution. Higher foe and Koc values increase the transport time;
therefore, the concentrations in Scenario B are lower compared with the concentrations in
Scenario A at each transport time. The concentrations in Scenario A (lower foe and Koc) reached
near-steady-state conditions  about  1 year after the source release. In Scenario B, it takes more
than 3 years to reach steady-state conditions. The transport time decreases if the source is
shallow, and it may take just days or a few months to reach  steady state. Once near-steady-state
conditions are reached, sorption sites are saturated and the foe and Koc values no longer affect
vapor distribution.

At sites with conditions that lead to a greater amount of contaminant sorption (i.e., sites with
high soil foe, high-Koc chemicals, or deep sources), changes over time in soil gas profiles might
not occur in parallel with changes over time in source conditions, because the available sorption
sites will tend to buffer changes in soil gas concentrations over time.
                                             92

-------
February 24, 2012
Conceptual Model Scenarios of the Vapor Intrusion Pathway
                       Scenario A                              Scenario B
             foe = 0.001,  koc = 60 cm3/g                foc = 0.005, koc = 600 cmP/g
                                            1 month
u

-1
-4




-fi-


-8
— 5
— -LI
a = 1.4E-6 \

00
.z
no







-_ n n 'i
U.U 1
0 1







T
I I I








—



— Ln |
1 I
a = lE-21 \

1E-7




. , 0.01
u.1
iii
      Figure 45. Effect of transport time on soil vapor distribution and normalized indoor air
                   concentrations (a) for scenarios with varying koc and foc.
          The soil vapor concentration contour lines are normalized by the source vapor concentration.
                              The building is at atmospheric pressure.
                                            93

-------
February 24, 2012                       Conceptual Model Scenarios of the Vapor Intrusion Pathway


6.2    Wind Load on Buildings
  The figures in this section illustrate that the wind load on a building wall can affect the pressure distribution on the
  ground surface around the building and in its sub-slab (Figure 46a), which can affect the sub-slab distribution of
  recalcitrant and aerobically biodegradable VOCs (Figure 46b). Note that these simulations assume steady-state
  conditions. In reality, the wind load and its concomitant impact on sub-slab VOC concentrations will likely vary
  overtime.
Wind blowing on the walls of a building will create a non-uniform atmospheric pressure
distribution on the ground surface. The wind speed falls to zero as it strikes the side of a
building, and the change in momentum from the free-stream speed can be related to the increase
in pressure at the wall. On the downwind side of the building, the increase in wind speed creates
a decrease in pressure. A wind-induced non-uniform pressure distribution on the ground surface
on either side of a building may cause spatial and temporal variability in the sub-slab soil vapor
concentration distribution. Luo et al. (2006) show this temporal and spatial variability at a site
with soils with high soil gas permeability and strong winds. The actual building, soil, and wind
data from that site were used as inputs to simulate the effect of wind on the sub-slab soil gas
distribution. As described below, the model predictions are consistent with the field data.

To simulate a steady wind load effect, a wind-induced non-uniform pressure distribution at
ground surface was applied as a boundary condition to the 3-D model. This pressure distribution
was calculated according to the method described by Riley et al. (1999) and Nazaroff and Nero
(1988). The simulations were performed for two contamination scenarios, a recalcitrant VOC
and a biodegradable hydrocarbon, both with a source vapor concentration of 160 mg/L. The
vapor source extends from 2 to 6 m bgs, there is a slab-on-grade foundation, and the water table
is 6 m bgs. The soil is homogeneous and has a relatively high gas permeability (1E-10 m2). The
pressure inside the building is assumed to be the same as the free-stream conditions (i.e., gauge
pressure is zero). Simulations were performed for two steady wind directions, north and
northeast, both at a velocity of 5 m/s (11 mph).  The reader is cautioned that, in most areas of the
country, wind loads are unlikely to remain at steady directions or velocities for long, and that
normal shifts in wind load (i.e., gusts) or direction can change the magnitude and direction of the
pressure differentials across a slab.

The wind-induced ground-surf ace gauge pressure distribution applied as a boundary condition
and the predicted sub-slab gauge pressure distribution for  each wind direction are presented in
Figure 46a and suggest about 10 Pa of pressure difference in the  sub-surface across building
walls in the wind direction. This pressure difference depends on wind speed. The predicted soil
gas sub-slab concentration distribution for each wind direction is presented in Figure 46b and
suggests about two orders of magnitude variability in sub-slab concentrations across the
foundation for recalcitrant chemicals and about three orders of magnitude variability for
biodegradable hydrocarbons with a high source concentration. The model simulations represent
predictions for relatively high soil gas permeability and wind speed. The effect of wind will be
less as soil gas permeability and wind decrease (Riley et al., 1996). However, these simulations
are performed at steady state, and in reality, wind is variable over time, which would contribute
to temporal variability in shallow subsurface vapor concentrations as shown by Luo et al. (2006).
                                            94

-------
February 24, 2012
                               Conceptual Model Scenarios of the Vapor Intrusion Pathway
                                      Plan View at Ground Surface
     45-
     40-
     35-
     30-
     25-
     20-
     15


      45



      40
                                                                    Building
                                                                                 —\
NE wind
                       Plan View at 0.2 m bgs (sub-slab depth)
                                                                 North wind
      15



[f


\



I

\\


5
•\


( 5
U 	 /p-
V — \^~~
V^""
) i
^~1<^___
//"3^iv--__
//r5^V__


^ -2 "^

20 25 30


	 ^x
^==\\\
~~4V5J//
~*^/V
~^^^J
^^1
__^i 	 XN
— -^F~\\
— ~/(r~^\
• 1
\
•5 	 ^})
^

35 40




/
/



\
\
\ \


/

4
             NE wind
                                                                                   North wind
                                                                                                   N
                                                                                                 Pa
                                                                                                B
                       	Building footprint
      Figure 46a. Effect of building wind load on ground surface and sub-slab gauge pressure
                                             distribution.
           The gauge pressure contour lines are in Pa; negative values reflect over-pressurization and
                                positive values reflect under-pressurization.
                                                  95

-------
February 24, 2012
                     Conceptual Model Scenarios of the Vapor Intrusion Pathway
                                     Recalcitrant VOC
                     Aerobically Biodegradable VOC ( A,= 0.18 h"1)
          40
      N
          35
          30
          25
          20>
\
                              150
                                                 \\Y\\Y\,
                                                  l\ \\ v\
                                                  !\\\s
                                                  \\ v^r
                                                                    JX4 |
  20     25     30      35
NE wind

        	Building footprint
                                         40   20     25
                                                   35     40

                                              North wind
                                                                                mg/L
                                                                          150

                                                                          130

                                                                          110

                                                                          90

                                                                          70

                                                                          50

                                                                          30

                                                                          10

                                                                          1

                                                                          0.1

                                                                          0
  Figure 46b. Effect of building wind load on sub-slab soil vapor distribution for recalcitrant and
                              aerobically biodegradable VOCs.
        The vapor concentration contour lines are in mg/L. The source vapor concentration is 160 mg/L.
                                      (Abreuetal.,2006)
                                            96

-------
February 24, 2012                       Conceptual Model Scenarios of the Vapor Intrusion Pathway
6.3    Atmospheric and Indoor Air Pressure Fluctuations
  The figures in this section illustrate the effect of barometric pressure fluctuations on the transport of soil gas into a
  building. Figure 47 depicts the barometric pressure fluctuations that were used in the simulations. Figure 48
  depicts the fluctuations in soil gas-indoor air pressure difference resulting from the barometric pressure cycling,
  and Figure 49 depicts the resulting changes in the magnitude and direction of air flow between the sub-slab and
  the building. As the atmospheric pressure decreases, sub-slab air tends to flow into the building and the indoor
  concentrations of VOCs increase. As the atmospheric pressure increases, basement air tends to flow into the
  sub-slab and the indoor air concentrations of VOCs decrease (Figure 50). Subslab concentrations also change in
  response to the magnitude and direction of air flow (Figure 51). The air permeability of the sub-slab affects the
  magnitude of the change in the pressure difference and the flow into or out of the building. The pressure
  difference between the building and the sub-slab are greater for less permeable soils,  but the flow rates are
  smaller.
Several published studies have demonstrated that barometric pressure fluctuations affect the
transport of soil gas into buildings (Robinson and Sextro, 1997; Robinson, Sextro, and Fisk,
1997; Robinson, Sextro, and Riley, 1997; Narasimhan et al., 1990). These atmospheric pressure
changes typically occur over several hours and affect the difference between soil gas pressure
and indoor air pressure, which is a driving force for vapor intrusion. The magnitude of the
induced pressure difference is related to the soil permeability and the magnitude of the
barometric pressure changes; the pressure difference generally decreases as the soil permeability
increases, and increases as the magnitude and rate of the barometric pressure change increases.
The pressure difference between a building and the subsurface may also have higher frequency
fluctuations due to changing wind load and lower frequency changes due to  changing
temperature. Use of doors and windows, ventilation fans, exhaust fans (stovetops, bathrooms),
central vacuum cleaners, window-mount air conditioners, and the like can also cause episodic
changes in pressure differentials. In combination, these variations in environmental and building
conditions lead to complex soil gas-indoor air pressure differential histories and temporal
changes in vapor intrusion rates; in some cases, these variations can also lead to flow from the
building to the soil (Luo et  al, 2006, 2007; Johnson, 2008).

In this section, 3-D model simulations3 are presented to illustrate that transient fluctuations in the
soil gas-indoor air pressure differential can affect air flow rates, indoor air concentrations, and
sub-slab vapor concentrations below a slab crack. For the purposes of illustration, a simple
idealized scenario was selected in which a sinusoidal barometric cycle fluctuates by 100 Pa over
4 hours (amplitude of 50 Pa and period of 4 hours), as illustrated in Figure 47. This idealized
barometric cycle does not represent the wide range of barometric pressure behaviors that occur in
real-world conditions, and it is used as an example for illustration purposes only.
3 The simulations used a revised indoor air mixing equation to properly account for the accumulation term resulting
  from the transient pressure fluctuations. Details are provided in Appendix A.
                                              97

-------
February 24, 2012
Conceptual Model Scenarios of the Vapor Intrusion Pathway
                      101,375
                      101,350 -,,


                      101,325 -
                    3
                    U)
                    U)
                    Si  101,300
                    Q.
                   •g  101,275 -
                   in
                   .Q
                      101,250 -
                      101,225
                         A=100 Pa
                                                 10
                                               time (h)
                                                            15
                                                                      20
         Figure 47. Barometric pressure fluctuations used in the simulations presented
                                  in Figures 48 through 51.

Two soil gas permeability conditions were simulated:  1E-12 m2 and 1E-11 m2. In each case, the
subsurface is homogeneous and a very extensive recalcitrant vapor source with a vapor
concentration of 10,000 ng/m3 is located 8 m bgs at the water table. The intention is to evaluate
the effects  of one parameter at a time, so all other parameters that could also influence the results
presented here are held constant (e.g., air exchange rates).

In these simulations, building indoor air pressure is set at atmospheric pressure conditions so that
the indoor-outdoor pressure differential is always zero. It should be noted that many buildings
are naturally under-pressurized relative to ambient conditions,  so the assumption of equal indoor
and outdoor pressures has implications for the results presented below, in particular the issue of
flow reversal (i.e., flow from the building into the soil), which may not occur to the same degree
as shown in these simulations.

Figure 48 presents the fluctuations in soil gas-indoor air pressure differential resulting from the
barometric pressure cycling. It shows that the soil gas-indoor air pressure differential oscillates
between positive and negative values. Figure 49 shows that in response to the  transient
fluctuations of the soil gas-indoor air pressure differential, the air flow rate also oscillates with
approximately the same period, with the air flow reversing direction at times when the indoor air
pressure exceeds the soil gas air pressure. This aspect of the model behavior is related to
prescribing equal indoor and outdoor pressures and would not occur in a situation where the
baseline building under-pressurization is greater than the soil gas-indoor air pressure
differentials seen in these simulations.

Figures 50 and 51 show that, when there is a reversal of flow direction from the building into the
soil, then the indoor air and the vapor concentration right below the slab crack may also oscillate.
For the simulations involving the higher air permeability, the indoor air concentration varies
within a factor of three (from 2 to 6 |ig/m3), and the sub-slab soil gas concentration variation is
within 40% (from 3,000 to 4,200  |ig/m3). These results are specific for the conditions simulated.
As the soil gas permeability decreases, the range of temporal variation in air flow rates and
concentrations decreases as well.
                                            98

-------
February 24, 2012
Conceptual Model Scenarios of the Vapor Intrusion Pathway
                                       (+) Building over-pressurized
                     .0

                     «

                     V
                     .a
                     3
                     i/)
                     o
                     o
                     •o
                     c
                                                time (h)


                                    	kg = 1 E-11 m2	kg = 1 E-12 m2



    Figure 48. Temporal variation in the pressure difference between indoor air and sub-slab air

         resulting from fluctuations in barometric pressure (Figure 47) for two soil types.

                          Soil gas permeabilities (kg) of 1E-12 m2 and 1E-11 m2.
                                  (+) Flow from subsurface to building
                         2.5 -
                       c

                       E





                       O
                         -2.5 -
                                               time (h)


                                  	kg = 1E-11 m2	kg = 1E-12 m2



  Figure 49. Temporal reversal of the airflow direction resulting from fluctuations in indoor-sub-

                               slab pressure difference (Figure 48).

                         Soil gas permeabilities (kg) are 1E-12 m2 and 1E-11 m2.
                                               99

-------
February 24, 2012
                  Conceptual Model Scenarios of the Vapor Intrusion Pathway
                    "3)
                    _3.

                    g
                    +J
                    2
                    4-1

                    I
                    o
                    o
                    o
                    a.
                    ns
 6-
 4-
                       2-
                    o
                    %  I
                    ^    o
                                     i           10          15

                                              time (h)

                                     -kg= 1E-11 m2	kg = 1E-12m2
                                                                        20
     Figure 50. Temporal variation of the indoor air VOC concentration (y-axis) resulting from
 fluctuations in indoor sub-slab pressure difference and reversals of airflow direction (Figures 48
                                            and 49).
  Source vapor concentration is 10,000 ug/m3 at 8 m bgs. Soil gas permeabilities (kg) are 1E-12 m2 and 1E-11 m2
                  E
                  "3)
                  _3.

                  O
                  is
                  
-------
February 24, 2012
Conceptual Model Scenarios of the Vapor Intrusion Pathway
6.4    Seasonal Phenomena
  The following subsections describe possible temporal and spatial changes in the distribution of VOCs that might
  take place from season to season. Although no model simulations of these seasonal changes were performed,
  the conceptual scenarios are illustrated to familiarize the reader with their potential impacts.
Seasonal variability is the change in vapor intrusion that occurs according to a season or a period
of the year associated with a particular seasonal phenomenon. For example, seasonal changes in
outdoor air temperature (and the resulting difference between indoor and outdoor air
temperatures) can affect building pressure via the stack effect, and seasonal changes in air
exchange rates can contribute to seasonal variations in the magnitude of vapor intrusion to indoor
air. Simulations showing the effects associated with such building conditions that can vary
seasonally are discussed in Section 4.3.3. This section briefly introduces two processes that can
cause seasonal variability in vapor intrusion that were not simulated for this document:
fluctuations in water table elevations and rainfall events.

6.4.1  Fluctuations in Water Table Elevation
  The figures in this section illustrate the effect that fluctuations in the water table elevation might have on the vapor
  source concentration. Figure 52 depicts conditions where a falling water table exposes a soil zone containing a
  hydrocarbon NAPL (i.e., a "smear zone"), thus increasing the available vapor source. Figure 53 depicts a case
  where a rising water table encounters soil zone NAPL. The NAPL dissolves into the formerly clean groundwater,
  and aqueous phase constituents are transported away from the source, expanding the area of contamination.
Fluctuations in the water table elevation may affect the distribution of contaminants in the
subsurface, the source-foundation separation, and, consequently, the magnitude of any vapor
intrusion. The extent of this effect depends on the location of the original vapor source. If the
contaminant vapor source is originally at the water table (e.g., dissolved groundwater or NAPL
plume) and the subsurface soil in the vadose zone above the water table is initially clean, as
shown in Figure 52, as the groundwater table rises and falls again, it leaves a contaminated soil
zone above the water table as a second source of contamination (or NAPL smear zone). The
water table will also act like a piston, forcing soil gas upward or drawing soil gas downward as
the water table rises and falls.
urigmai

Clean soil
^^^
Groundwater source
Rising p.
ill t^ fPi IPI CT!

fnfni inHw^tpr ^niirpp

Falling .-,
f f f f f
Contaminated soil

Groundwater source
  Figure 52. Schematic illustration of water table fluctuations and the increase of VOC-impacted
                               area from a groundwater source.
                                             101

-------
February 24, 2012
   Conceptual Model Scenarios of the Vapor Intrusion Pathway
A second scenario, shown in Figure 53, can occur when the original vapor source is residual
NAPL in soil, and the groundwater below it is initially clean. As the groundwater table rises and
reaches the NAPL-contaminated soil, contaminants dissolve into the groundwater and may
migrate with the groundwater flow to an area of larger extent than the original soil source and
may ultimately migrate to beneath a nearby building, increasing the subsurface VOC
concentration beneath it. As the now-contaminated groundwater table falls after a rising cycle, it
generates a contaminated soil zone that was initially clean. Thus, two new source zones were
created: a contaminated groundwater zone and a larger soil contamination zone extending
beneath the building.
          Original
                       XX
                         n
Rising
             XX
                soil source
           Clean groundwater
               n
Falling
            XX

              n
                                Contaminated groundwater
                         Contaminated soil
                      Contaminated groundwater
  Figure 53. Schematic illustration of water table fluctuations and the increase of VOC-impacted
                      area from a vadose zone (unsaturated soil) source.
In cases where lighter-than-water NAPL is present near the water table, the rate of mass transfer
to overlying soil gas increases when the water table falls because the drainage of water exposes
more of the NAPL to the gas phase. A falling water table can allow the LNAPL to migrate to
deeper depths (the NAPL smear zone), and when the water table rises again, some of that mass
will remain trapped by capillary forces below the water table, which would reduce the generation
of vapors.
                                           102

-------
February 24, 2012                      Conceptual Model Scenarios of the Vapor Intrusion Pathway


6.4.2  Rainfall Events and Water Infiltration
  There are no figures in this section, but the role of a structure as a moisture barrier and the role of a lens of fresh
  water at the water table overlying a zone of dissolved phase contamination are briefly discussed.
A building structure may represent a barrier for infiltration of rain water into the subsurface
immediately below the building footprint, which may result in a non-uniform distribution of soil
moisture content (Tillman and Weaver, 2007). During or after a rainfall event, the subsurface
beneath the building may have a lower moisture content than the adjacent areas. Localized wet
soil layers on the ground surface adjacent to the building may act as barriers to vertical vapor
transport toward the atmosphere, and the vapor migration may be diverted toward the building
and may increase the sub-slab concentration. The significance of this process depends on the
duration of the rainfall event, the soil type, the subsurface water infiltration and drainage
capacity, run-off, and evaporation and transpiration.

In locations where there is significant infiltration through the unsaturated zone, a layer of clean
groundwater may build up on top of the contaminated groundwater plume and act as a barrier to
VOC volatilization from the groundwater to soil gas and may decrease the soil vapor
concentration  distribution in the subsurface. This process has been referred to as clean water lens
(Fitzpatrick and Fitzgerald, 1996) and diving plumes (Griesemer, 2001). Also, if the soil is
coarse grained and there is high downwards drainage of the infiltrating water through the soil,
the water may flush the contaminant from the soil gas as it infiltrates down the subsurface, which
may also decrease the soil vapor concentration (Mendoza and McAlary,  1990).
                                            103

-------
February 24, 2012                       Conceptual Model Scenarios of the Vapor Intrusion Pathway
                             [This page intentionally left blank.]
                                            104

-------
February 24, 2012                       Conceptual Model Scenarios of the Vapor Intrusion Pathway

7.0   Examples Comparing Soil Gas Concentration at Different
       Locations
  This section uses examples from simulations presented in this report to illustrate the impacts of sample location
  selection and to highlight the fact that vapor concentrations at exterior sample locations may be either similar to or
  different from sub-slab concentrations depending on site-specific conditions and sampling depth. In the
  simulations, the red circles depict concentrations that would be obtained from samples at sub-slab locations. The
  red triangles depict concentrations that would be obtained from soil gas samples at their respective locations.
  Figure 54 depicts a scenario with a laterally extensive groundwater vapor source. Figure 55 depicts scenarios
  where a finite groundwater vapor source is at varying lateral distances from a building. Figure 56 depicts a
  scenario with multiple buildings and multiple sources. These simulations highlight the importance of developing
  and using an accurate site conceptual model when choosing sampling locations and interpreting sampling results.
This document is intended to provide a theoretical understanding of vapor intrusion processes
and to illustrate how different site conditions might influence the distribution of VOCs in the
subsurface and the indoor air of buildings in the vicinity of a soil or groundwater contaminant
source. The previous sections indicate that VOC concentration distributions in the subsurface
may not be uniform (including the sub-slab concentration distribution). This section uses the
previous results and makes comparisons between concentrations in different locations,
highlighting, for example,  how the simulations indicate that vapor concentration at exterior
sample locations may be similar to or different from sub-slab concentration, depending on site-
specific conditions (including depth).

As described earlier and illustrated in the figures below, when interpreting the nature and extent
of soil gas contamination, it is important to discern the source of VOCs in soil gas (soil or
groundwater), as well as the subsurface conditions (e.g., homogeneous, heterogeneous), the types
of ground cover and buildings, and the persistence of the chemicals of interest.

The simulations presented in this section are examples illustrating soil and groundwater sources
at different locations. Figure 54 illustrates a vapor concentration distribution for a laterally
extensive groundwater source directly below a residential building overlying homogeneous
subsurface soils and recalcitrant VOCs. This figure shows that the concentration at exterior
locations right above the source (if groundwater is shallow) or somewhat deeper than the
foundation depth (e.g., more than  3 m  below the foundation depth) could approximate the
concentrations expected in sub-slab locations. Some limited field data with an adequate number
of observations from groundwater-source scenarios have observations that are in general
agreement with the results presented in Figure 54 (e.g., Wertz, 2006; DiGiulio, 2006; Patterson
and Davis, 2009).
                                             105

-------
February 24, 2012
Conceptual Model Scenarios of the Vapor Intrusion Pathway
                                                8    10   12    14   16
                          -18
                            024
  Figure 54. Scenarios with extensive groundwater source directly below a building. The symbols
                    highlight areas for comparing soil vapor concentrations.
                      Circles are sub-slab locations; triangles are exterior locations.

Figure 55 illustrates a set of related scenarios where the VOC source, which is located at the
groundwater table, is positioned at a different lateral distance from a building with a basement.
Figure 56 illustrates a scenario with two distinct VOC sources: one located at the groundwater
table near a building with a basement and the other in the unsaturated soil zone near a building
with a slab-on-grade foundation. From Figures  55 and 56, it should be noted that in some
exterior locations (i.e., red triangles), soil gas concentrations are constant with depth, while in
other exterior locations, the  soil gas concentrations increase with depth (i.e., above the
groundwater source), and in other locations, the soil gas concentrations increase and decrease
with depth (i.e., where there is a soil source). These figures also illustrate that the sub-slab soil
gas concentrations (i.e., red  circles) can be higher, lower, or similar to the exterior locations,
depending on the VOC source location(s) and the specific exterior location and depth.
                                            106

-------
February 24, 2012
                Conceptual Model Scenarios of the Vapor Intrusion Pathway
      -6-
 r
10
                             Vapor Source
20
30
40
50
60
                                                               70
 I
80
90
                                                               100

— ^-"~"
^A

A
/ / ^—
-1 r-/ c 1
1 6-5 -i F/_4 1
A

L f

^

i
i
i
]3



ns
Fb
! — h

O

0.



3



/
i

1


a = 1.3E-5


0.1 0.3
"A °-4
^^ 05
_ oT^
A ^^
///-— 0.8- |\\ \
J -^- ll
Vapor Source
   (/)
   D)
   JD  -4-


   "S.
   O)
   Q
                10
20
                30
                40
                50
                60
                70
                80
        90      100
   Q.
   O)
   Q
                                                                                       100
 Figure 55. Scenarios with a groundwater source at different lateral distances from a building. The
                symbols highlight areas for comparing soil vapor concentrations.
                      Circles are sub-slab locations; triangles are exterior locations.
                                             107

-------
February 24, 2012
                Conceptual Model Scenarios of the Vapor Intrusion Pathway
                               Vertical Cross-Section View
                IA=1.1 ug/md
                Qs = 4 L/min
                                     IA= 7.7 ug/nr
                                     Qs= 5 L/min
    -2
 \Jl   .
E5  -4
tL
                                          100"
       |  Vapor Source
                                               o
                                               o
                                               p
                                               Ovi
              10
20
30
40
 50
x(m)
70
80
90      100
 Figure 56. Scenario with multiple buildings and multiple sources. The symbols highlight areas for
                            comparing soil vapor concentrations.
                      Circles are sub-slab locations; triangles are exterior locations.


The analysis provided in this section is based on just a few examples. The reader should keep in
mind that many other scenarios are presented in this technical document (e.g., scenarios with
heterogeneous subsurface, scenarios with biodegradation, scenarios under transient conditions).
The exact depth, number, and locations of soil gas samples can depend on site-specific
conditions and should be decided based on the nature,  extent, and fate and transport of vapors;
and the conceptual model of the source, pathway, and receptor relationships.
                                           108

-------
February 24, 2012                      Conceptual Model Scenarios of the Vapor Intrusion Pathway


8.0   Summary of Results

This document was prepared to help environmental practitioners gain insight into the processes
and variables involved in the vapor intrusion pathway and to provide a theoretical framework
with which to better understand the complex vapor fate and transport conditions typically
encountered at actual contaminated sites. Site-specific conditions may lead to more complex
VOC distributions than shown for the simplified conceptual model scenarios used in this
technical document. Nevertheless, the following general observations can be made from these
theoretical analyses and may be useful when considering the vapor intrusion pathway at a
particular site. Report sections are provided so the reader can review examples and understand
the basis and limitations for each observation:

    •  The horizontal and vertical distance over which vapors may migrate in the subsurface
       (primarily by diffusion) depends on the concentration of the source (Sections 4.1 and
       5.1), the source depth (Sections 4.2 and 5.2), the soil matrix properties (e.g., porosity and
       moisture content, Sections 4.4 and 5.4), the thickness of the vadose zone, and the time
       since the release occurred (Section  6.1).

    •  Subsurface heterogeneities in site geology (e.g., layering, moisture content; see Sections
       4.4, 5.4, and 5.5) influence the extent of vapor transport from a contaminant source to
       overlying or adjacent buildings.

    •  Advective flow occurs predominantly near cracks and openings in the building
       foundation slab and may affect the distribution of VOCs directly beneath the structure
       (Section 3.2). Heterogeneities in the permeability of geologic materials and backfill
       (Section 4.3.2), along with wind effects and building and atmospheric pressure temporal
       variation, may contribute to spatial  and temporal variability of VOC concentrations in
       sub-slab soil gas and indoor air (Section 6).

    •  The distribution of VOCs in soil gas beneath a building is not the only factor that
       determines the indoor air concentration. The indoor air VOC concentration is also
       influenced by building conditions, including the existence of cracks in the foundation,
       building pressurization, and air exchange rate, which in turn can be related to other
       factors such as temperature, wind, barometric pressure, occupant behavior, and building
       operations (Section 4.3).

    •  In cases where the subsurface is homogeneous, building conditions are the same (e.g., air
       exchange rate, pressurization), and the source vapor concentration extends evenly
       beneath each building, the presence of multiple single-family residences at typical
       spacing would be expected to have  little or no effect on the predicted indoor air VOC
       concentrations for a single building under these specific conditions (Section 4.3).

    •  Simulations assuming an impermeable ground cover suggest that shallow soil gas VOC
       concentrations can be higher under  low permeability ground covers than under open soil
       (Section 4.4.3). Note that this document illustrates simulation output for idealized (i.e.,
       impermeable) engineered surfaces,  which is a simplification.
                                           109

-------
February 24, 2012                      Conceptual Model Scenarios of the Vapor Intrusion Pathway
    •  The soil gas distribution of aerobically biodegradable chemicals (e.g., many petroleum
       compounds) can be significantly different from that of recalcitrant chemicals that do not
       readily degrade aerobically (e.g., chlorinated solvents) in similar settings (Section 5).

    •  The simulations presented in this technical document illustrate that the VOC
       concentrations in the subsurface may not be uniform (either in sub-slab soil gas or in soil
       gas at similar depths exterior to the building of concern). Therefore, VOC concentrations
       at exterior locations may be similar to or different from the sub-slab concentration,
       depending on site-specific conditions and the location and depth of the sample. Section 7
       shows examples for some different scenarios.

The conceptual scenarios simulated in this technical document illustrate that several factors
influence the distribution of VOC concentrations in soil gas and in indoor air and suggest that
assessment of the distribution of VOC concentrations in soil gas at sites and in indoor air can be
supported by characterization of the source extent, site geology, building conditions,
biodegradation, and other site-specific factors that can influence the distribution of VOCs in the
subsurface and their migration into the indoor air of overlying buildings.
                                            110

-------
February 24, 2012                      Conceptual Model Scenarios of the Vapor Intrusion Pathway


9.0    References

Abreu, L.D.V. 2005. A Transient Three-dimensional Numerical Model to Simulate Vapor
       Intrusion into Buildings. UMI 3166060, Ph.D. Dissertation, Arizona State University,
       Tempe, AZ.

Abreu, L.D.V., and P.C. Johnson. 2005. Effect of vapor source-building separation and building
       construction on soil vapor intrusion as studied with a three-dimensional numerical model.
       Environmental Science and Technology 39(12):4550-4561.

Abreu, L.D.V., and P.C. Johnson. 2006. Simulating the effect of aerobic biodegradation on soil
       vapor intrusion into buildings: influence of degradation rate, source concentration, and
       depth. Environmental Science and Technology 40(7):2304-2315.

Abreu, L.D.V., P.C. Johnson, and T.A. McAlary. 2006. 3-D Model Simulations and Implications
       to Near-Building Sampling. Presented at the Summary Workshop in the Context of EPA's
       VI Guidance Revisions, Association for Environmental Health and Sciences (AEHS)
       16th Annual West Coast Conference on Soils, Sediment, and Water; San Diego, CA,
       March 16. Available at http://iavi.rti.orgAVorkshopsAndConferences.cfm.

Abreu, L.D.V.; R. A. Ettinger, and T. McAlary. 2009a. Simulated vapor intrusion attenuation
       factors including biodegradation for petroleum hydrocarbons.  Ground Water Monitoring
       and Remediation 29(1): 105-117.

Abreu, L.D. V., R. A. Ettinger, and T.A. McAlary. 2009b. Simulating the Effect of Aerobic
       Biodegradation on Soil Vapor Intrusion into Buildings: Evaluation of Low Strength
       Sources associated with Dissolved Gasoline Plumes. API Publication 4775. API:
       Washington, DC. April.

Bozkurt, O.,  K. Pennell, and E.M. Suubery. 2009. Simulation of the vapor intrusion process for
       nonhomogeneous soils using a three-dimensional numerical model. Ground Water
       Monitoring and Remediation 29(1): 92-104.

Davis, R. 2009. Bioattenuation of petroleum hydrocarbon vapors in the subsurface: Update on
       recent studies and proposed screening criteria for the vapor intrusion pathway. L. U.S. T.
       Line Bulletin 61 (May): 11-14.

Denman, A.R., R.G.M. Crockett, C.J. Groves-Kirkby, P.S. Phillips, G.K. Gillmore, and A.C.
       Woolridge. 2007. The value of seasonal correction factors in assessing the health risk
       from  domestic radon—A case study in Northamptonshire, UK. Environment
       International 33:34-44.

DeVaull, G.E. 2007. Indoor vapor intrusion with oxygen-limited biodegradation for a subsurface
       gasoline source. Environmental Science and Technology 41(9):3241-3248.

DiGiulio, D. 2006. Evaluation of the "Constrained Version " of the J&E Model and Comparison
       of Soil-Gas and Sub-Slab Air Concentrations at the Raymark Superfund Site. Presented at
       the Summary Workshop in the Context of EPA's VI Guidance Revisions, AEHS 16th
                                          111

-------
February 24, 2012                      Conceptual Model Scenarios of the Vapor Intrusion Pathway


       Annual West Coast Conference on Soils, Sediment, and Water; San Diego, CA, March
       16. Available at http://iavi.rti.org/WorkshopsAnd Conferences.cfm.

Falta, R.W., I. Javandel, K. Pruess, and P. A. Witherspoon. 1989. Density-driven flow of gas in
       the unsaturated zone due to the evaporation of volatile organic compounds. Water
       Resources Research 25(10):2159-2169.

Fitzpatrick, N.A., and JJ. Fitzgerald. 1996. An Evaluation of Vapor Intrusion into Buildings
    Through a Study of Field Data. Presented at the 11th Annual Conference on Contaminated
    Soils, University of Massachusetts at Amherst, October.

Folkes D., W. Wertz, J. Kurtz, and T. Kuehster. 2009. Observed spatial and temporal
       distributions of CVOCs at Colorado and New York vapor intrusion sites. Groundwater
       Monitoring and Remediation 29(1):70-80.

Freeze, A. and J. Cherry, 1979. Groundwater. Prentice Hall, Inc., Englewood Cliffs, New Jersey.

Griesemer, J. 2001. Diving plumes: The development and investigation of dissolved contaminant
       plumes that migrate vertically downward to depths below the water table. NJDEP Site
       Remediation News 13(1), May.

Groves-Kirkby, C.J., A.R. Denman, R.G.M. Crockett, P.S. Phillips, A.C. Woolridge, and G.K.
       Gillmore. 2006. Time-integrating radon gas measurements in domestic premises:
       Comparison of short-, medium- and long-term exposures. Journal of Environmental
       Radioactivity 86(1):92-109.

Hers, I, J. Atwater, L. Li, and R. Zapf-Gilje. 2000. Evaluation of vadose zone biodegradation of
       BTX vapours. Journal of Contaminant Hydrology 46:233-264.

Hers, L, R. Zapf-Gilje, P.C. Johnson, and L. Li, 2003. Evaluation of the Johnson and Ettinger
       model for prediction of indoor air quality. Ground Water Monitoring and Remediation
       23(l):62-76.

Hughes, B., Frind, E. and C. Mendoza, 1996. Vapor transport of trichloroethylene in the
       unsaturated zone: Field and numerical modeling investigations. Water Resources
       Research 32(1): 9-22.

ITRC (Interstate Technology and Regulatory Council). 2007. Vapor Intrusion Pathway: A
       Practical Guideline. VI-1. Interstate Technology & Regulatory Council, Vapor Intrusion
       Team, Washington, DC. Available atwww.itrcweb.org.

Jin, Y., T. Streck, and W.A. Jury.  1994. Transport and biodegradation of toluene in unsaturated
       soil. Journal of Contaminant Hydrology 17:111-127'.

Johnson, P.C. 2002. Identification of Critical Parameters for the Johnson and Ettinger (1991)
       Vapor Intrusion Model. API Soil and Groundwater Research Bulletin Number 17. May.
       Available at http://www.api.org/ehs/groundwater/criticalparameters.cfm.
                                          112

-------
February 24, 2012                      Conceptual Model Scenarios of the Vapor Intrusion Pathway


Johnson, P.C. 2005. Identification of application-specific critical inputs for the  1991 Johnson and
       Ettinger vapor intrusion algorithm. Ground Water Monitoring & Remediation 25(1):63-
       78.

Johnson, P.C. 2008. The Path to More Confident and Cost-Effective Vapor Intrusion Pathway
       Assessment. Presented at the Association for Environmental Health and  Sciences
       (AEHS), March 12, San Diego, CA. Available at http://iavi.rti.org/attachments
       /WorkshopsAndConferences/0 l_Johnson_Presentation.pdf

Johnson, P.C., and R.A. Ettinger. 1991. Heuristic model for predicting the intrusion rate of
       contaminant vapors into buildings. Environmental Science and Technology 25:1445-
       1452.

Johnson, P. C., C.C. Stanley, M.W. Kemblowski, D.L. Byers, and J.D. Colthart. 1990. A
       practical approach to the design, operation,  and monitoring of in situ soil-venting
       systems. Ground Water Monitoring and Remediation 10(2): 159-178.

Johnson, R.L., K.A. McCarthy, M. Perrott, and C.A. Mendoza.  1992. Density-driven vapor
       transport: Physical and numerical modeling. In Weyer (ed.), Subsurface Contamination
       by Immiscible Fluids. Balkema: Rotterdam.

Johnson, P.C., M.W. Kemblowski, and R.L. Johnson. 1999. Assessing the significance of
       subsurface contaminant vapor migration to enclosed spaces:  Site-specific alternatives to
       generic estimates. Journal of Soil Contamination 8(3):389-421.

Johnson, P.C., R.A. Ettinger, J. Kurtz, R. Bryan, and J.E. Kester, 2002. Migration of Soil Gas
       Vapors to Indoor Air: Determining Vapor Attenuation Factors Using a Screening-Level
       Model and Field Data from the CDOT-MTL Denver, Colorado.  API Soil and
       Groundwater Task Force Bulletin No. 16; American Petroleum Institute: Washington,
       DC.

Lowell, P.S., and B. Eklund. 2004. VOC emission fluxes as a function of lateral distance from
       the source. Environmental Progress 23(l):52-58.

Luo, H., P. Dahlen, P. Johnson, T. Creamer, T. Peargin, P. Lundegard, B. Hartman, L. Abreu,
       and T. McAlary. 2006. Spatial and Temporal Variability in Hydrocarbon and Oxygen
       Concentrations Beneath a Building Above a Shallow NAPL Source. Presented at the
       Battelle Conference on Remediation of Chlorinated and Recalcitrant Compounds,
       Monterey, CA. May.

Luo, H., P. Dahlen, P.C. Johnson, T. Creamer, T, Peargin, and T. McAlary. 2007. Spatial and
       Temporal Variability of Sub-Slab Soil Gas Concentrations at a Petroleum-Impacted Site.
       Presented at the American Waste Management Association (AWMA) Conference: Vapor
       Intrusion: Learning from the Challenges. September 26-28. Providence, RI.

Marley, F. 2001. Investigation of the influences of atmospheric conditions on the variability of
       radon  and radon progeny in buildings. Atmospheric Environment 35:5347-5360.
                                          113

-------
February 24, 2012                     Conceptual Model Scenarios of the Vapor Intrusion Pathway


McAlary, T.A., Nicholson, P., Yik, L.K., Bertrand, D. and G. Thrupp. 2010. High purge volume
     sampling—A new paradigm for sub-slab soil gas monitoring. Groundwater Monitoring
     and Remediation 30(2):73-85.

Mendoza, C.A., and E.O. Frind. 1990. Advective-dispersive transport of dense organic vapors in
       the unsaturated zone, 2. Sensitivity analysis. Water Resources Research 26(3):388-398.

Mendoza, C.A. and T.A. McAlary. 1990. Modeling of groundwater contamination caused by
       organic solvent vapours. Ground Water 28(2): 199-206.

Mosley, R.B. 2007. Use of Radon Measurements to Analyze Vapor Intrusion Problems.
       Workshop on Soil-Gas Sample Collection and Analysis. Presented at the 17th Annual
       Association for Environmental Health and Sciences (AEHS) Meeting and West Coast
       Conference  on Soils, Sediments, and Water. San Diego, CA. March.  Available at
       http://iavi.rti.orgAVorkshopsAndConferences.cfm?PageID=documentDetails&AttachID=
       363.

Narasimhan, T.N., Y.W. Tsang, and H.Y. Holman.  1990. On the importance of transient air flow
       in advective entry into buildings. Geophysical Research Letters 17(6):821-824.

Nazaroff, W.W., and A.V. Nero. 1988. Radon and Its Decay Products in Indoor Air. New York,
       NY: J. Wiley & Sons.

Nazaroff, W.W., S.R. Lewis, S.M. Doyle, B.S. Moed, and A.V. Nero. 1987.  Experiments on
       pollutant transport from soil into residential  basements by pressure-driven airflow.
       Environmental Science and Technology 21(5):459-466.

Nielson, K.K., V.C. Rogers, R.B. Holt, T.D. Pugh, W.A. Grondzik, and RJ.  Meijer.  1997. Radon
       penetration of concrete slab cracks, joints, pipe penetrations, and sealants. Health Physics
       73(4):669-678.

Pasteris, G., D. Werner, K. Kaufmann, and P. Hohener. 2002. Vapor phase transport and
       biodegradation of volatile fuel compounds in the unsaturated zone: A large scale
       lysimeter experiment. Environmental Science and Technology 36(l):30-39.

Patterson, B.M., and G.B. Davis. 2009. Quantification of vapor intrusion pathways into a slab-
       on-ground building under varying environmental  conditions. Environmental Science and
       Technology 43(3):650-656.

Pennell, K.G., O. Bozkurt, and E.M. Suuberg. 2009. Development and application of a three-
       dimensional finite element vapor intrusion model. Journal of the Air  and Waste
       Management Association 59:447-460. DOT: 10.3155/1047-3289.59.4.447.

Renken, K.J., and T. Rosenberg. 1995. Laboratory measurements of the transport of radon gas
       through concrete samples. Health Physics 68(6):800-808.

Riley, W.J., AJ. Gadgil, Y.C. Bonnefoud, W.W. Nazaroff. 1996. The effect  of steady winds on
       radon-222 entry from soil into houses. Atmospheric Environment 30(7): 1167-1176.
                                         114

-------
February 24, 2012                      Conceptual Model Scenarios of the Vapor Intrusion Pathway


Riley, W.J., A.L. Robinson, AJ. Gadgil, W.W. Nazaroff. 1999. Effects of variable wind speed
       and direction on radon transport from soil into buildings: model development and
       exploratory results. Atmospheric Environment 33:2157-2168.

Rivett, M.O. 1995. Soil-gas signatures from volatile chlorinated solvents: Borden Field
       experiments. Ground Water 33(l):84-98.

Robinson, A.L., and R.G. Sextro. 1997. Radon entry into buildings driven by atmospheric
       pressure fluctuations. Environmental Science and Technology 31:1742-1748

Robinson, A.L., R.G. Sextro, and WJ. Fisk. 1997.  Soil-gas entry into an experimental basement
       driven by atmospheric pressure fluctuations—Measurements, spectral analysis and model
       comparison. Atmospheric Environment 31(10): 1477-1485.

Robinson, A.L., R.G. Sextro, and WJ. Riley. 1997. Soil-gas entry into houses driven by
       atmospheric pressure fluctuations—The influence of soil properties. Atmospheric
       Environment 31(10): 1487-1495.

Rogers, V.C, K.K. Nielson, R.B. Holt, and R.  Snoddy. 1994. Radon diffusion coefficients for
       residential concretes. Health Physics 67(3):261-265.

Roggemans, S., C.L. Bruce, and P.C. Johnson. 2001.  Vadose Zone Natural Attenuation of
       Hydrocarbon Vapors: An Empirical Assessment of Soil Gas Vertical Profile Data. API
       Technical Bulletin No. 15. American Petroleum Institute: Washington, DC.

Rowe I.E., M. Kelly, and L.E. Price. 2002. Weather system scale variation in radon-222
       concentration of indoor air. Science of the Total Environment 284(1-3): 157-166.

Steck, DJ. 1992. Spatial and temporal indoor radon variations. Health Physics 62(4):351-355.

Tillman, F.D. and J.W. Weaver. 2007. Temporal moisture content variability beneath and
       external to a building and the potential effects on vapor intrusion risk assessment. Science
       of the Total Environment 379:1-15.

U.S. Census Bureau. 2006. American Housing Survey for the United States: 2005. Current
       Housing Reports, Series H150/05. U.S. Government Printing Office, Washington, DC.
       Available at http://www.census.gov/prod/2006pubs/hl50-05.pdf.

U.S. EPA (Environmental Protection Agency). 2002. OSWER Draft Guidance for Evaluating the
       Vapor Intrusion to Indoor Air Pathway from Groundwater and Soils (Subsurface Vapor
       Intrusion Guidance). EPA530-D-02-004. U.S. EPA, Office of Solid Waste and
       Emergency Response, Washington, DC. November.

U.S. EPA (Environmental Protection Agency). 2004. User's Guide for Evaluating Subsurface
       Vapor Intrusion into Buildings. Prepared by Environmental Quality Management, Inc. for
       U.S. EPA Office of Emergency and Remedial Response, Washington DC, February 22.
       Available at http://www.epa.gov/oswer/riskassessment/airmodel/pdf/
       2004_0222_3phase_users_guide.pdf.
                                          115

-------
February 24, 2012                     Conceptual Model Scenarios of the Vapor Intrusion Pathway


U.S. EPA (Environmental Protection Agency). 201 la. Background Indoor Air Concentrations of
       Volatile Organic Compounds in North American Residences: A Compilation and
       Implications for Vapor Intrusion. EPA 530-R-10-001. U.S. EPA, Office of Solid Waste
       and Emergency Response, Washington, DC. June. Available at
       http://www.epa.gov/oswer/vaporintrusion/documents/oswer-vapor-intrusion-background-
       Report-062411.pdf.

U.S. EPA (Environmental Protection Agency). 201 Ib. Petroleum Hydrocarbons And
       Chlorinated Hydrocarbons Differ In Their Potential For Vapor Intrusion. U.S. EPA,
       Office of Underground Storage Tanks, Washington, DC. September. Available at
       http://www.epa.gov/swerustl/cat/pvi/pvicvi.pdf.

Wertz, W. 2006. Near-Building and Sub-slab Sampling at the Endicott (NY) Site, Implications
      for Site Screening Approaches.  Presented at the Summary Workshop in the Context of
       EPA's VI Guidance Revisions,  AEHS 16th Annual West Coast Conference on Soils,
       Sediment, and Water;  San Diego, CA, March 16. Available at http://iavi.rti.org/
       Workshops AndConferences.cfm.
                                         116

-------
Model Equations                                             Appendix A
                         Appendix A
                      Model Equations
                              A-l

-------
Model Equations                                                                  Appendix A
                             [This page intentionally left blank.]
                                            A-2

-------
Model Equations                                                           Appendix A


A.I   Summary of Model Equations

Table A-l shows the equations solved by the numerical code, and Table A-2 shows the
boundary conditions used. The symbols used are defined following each table.
                                       A-3

-------
Model Equations
                                                     Appendix A
                      Table A-l. Equations Solved by the Numerical Code
      Parameter
                     Equation
 Soil gas disturbance
 pressure field
 Soil gas flow field
                                                        M-g
 Chemical transport:
 advection, diffusion,
 and aerobic
 biodegradation
<5C-
                       where
                                                a=l(l)g+-^--
                               H;
                                                                10/3
                                          'ig-
                       RI is zero if the chemical is recalcitrant. If the chemical is biodegradable then the Rj used
                       in this work is a first-order model limited by oxygen concentration:


                                     t — 0  • A,- ' C^    //  (^oxygen ^ Cog

                                     tj — 0            IJ  (^oxygen ^ Cog

                       The reaction  rate for oxygen (R0) is determined stoichiometrically:
                                                            m
                                                       R0 =
 Indoor air
 concentration
        ^i
                                               ndoor _   s   ' b '   ex '
                       where
                       and
                      n-^r+G.
                Qs=    1  Qck
                        Lck


                exp |    Qc^   dck
                                           Lck
          Qck
                                                                               indoor
                     exp
                                                                   -ck
                                                                        dck  -
•dLP
                                                                                         ck
                                                A-4

-------
Model Equations                                                                 Appendix A

Definition of Symbols Used in Table A-l

p:       disturbance pressure (absolute atmospheric pressure minus absolute soil gas pressure at
         a point) [M/L/T2]
         time [T]
         mean soil gas pressure (approximated by the atmospheric pressure for the problems of
         interest here) [M/L/T2]
g.      gas-filled porosity [L3gas/L3soii]
//g :      soil gas dynamic viscosity [M/L/T]
V:      vector del operator [L"1]
Kg:      soil permeability to soil gas flow [L2]
(]„:      soil gas discharge vector [L3gas/L2area/T]
/':        chemical-specific subscript
Cig:      gas-phase concentration of chemical /' [Mi/L3gas]
qw:      soil moisture specific discharge vector [L3fluid/L2area/T]
Rt:      net loss rate of chemical /' due to reaction [Mi/L3soii/T]
w :      moisture-filled porosity [L3water/L3soii]
Pb'.      soil bulk density [Msoii/L3soii]
foe'.      mass fraction of organic carbon in the soil  [Moc/Msoii]
Koc,i :    sorption coefficient of chemical / to organic carbon [(Mi/M0c)/(Mi/L3water)]
Hi.      Henry's law constant for chemical /' [(Mi/L3gas)/(Mi/L3water)]
Dig.      effective porous media diffusion coefficients for chemical / in soil gas [L2/T]
Diw:     effective porous media diffusion coefficients for chemical /' in soil moisture [L2/T]
df:      molecular diffusion coefficient of chemical /' in air [L2/T]
d™ :     molecular diffusion coefficient of chemical /' in water [L2/T]
r :      total soil porosity (= g + ^) [L3pores/L3soii]
AJ:      first-order reaction rate [1/T]
Coxygen'-  oxygen soil gas concentration [M/L3-vapor]
rk0 :     ratio of oxygen to hydrocarbon consumed [M0/M;]
m:      total number of aerobically degrading chemicals
Es:      emission rate of chemical /' to enclosed space [M/T]
Aex:     enclosed space air exchange rate [1/T]
Vb :      enclosed space volume [L3] where indoor air is assumed fully mixed
Ci,amb:   concentration of chemical /' in ambient air [M/L3]
Qs:      soil gas flow rate to the enclosed space [L3/T]
Cog™":   threshold oxygen concentration for aerobic biodegradation to occur.
                                           A-5

-------
Model Equations
                                            Appendix A
                                 Table A-2. Boundary Conditions
             Boundaries
             Boundary Condition(s)
 All vertical plane-of-symmetry, all lateral
 boundaries, solid foundation sections,
 and the lower model domain boundary
                   Vp- n =0


n = 0 (except at the vapor source boundary)
 Vapor source boundary
                                                                      -i source
  Soil-atmosphere interface
                                           (f\ = 0
                                           \ '
                                                   for steady atmospheric pressure, otherwise
                                            patm (t) =
                                                                  clg =
                                                       0xygen
                                                                         (0.28 mg/cm)
  Disturbance pressure within the
  building
  Foundation crack-soil interface.
                                                     12//  -dak
                                                                               = w
                                                                                   ck
                                                    exp
                                                         exp
                                             = W
                                                      C
                                                                                       K
                                                                                        g
                                s~i     s~i irta

                                  ig     'g
                                                                                -1
                           -D
                                                 A-6

-------
Model Equations                                                                Appendix A

Definition of Symbols Used in Table A-2
—>
n :       unit vector normal to the surface of interest
patm(t):   disturbance pressure at the soil-atmosphere interface [M/L/T2]
pmdoor(t): disturbance pressure within the building [M/L/T2]
&ps(f)'.   pressure difference between the indoor air and the atmospheric air (or gauge pressure)
A:       user-defined amplitudes [M/L/T2]

-------
Model Equations                                                                  Appendix A
                             [This page intentionally left blank.]
                                            A-8

-------
Model Inputs and Assumptions                                     Appendix B
                         Appendix B
               Model Inputs and Assumptions
                              B-l

-------
Model Inputs and Assumptions                                                      Appendix B
                             [This page intentionally left blank.]
                                           B-2

-------
Model Inputs and Assumptions
Appendix B
                       Table B-l. Model Inputs and Assumptions
Input/Assumption
Baseline Value
Alternative Values Modeled
Building and Foundation Assumptions
Residential home
Building dimensions3
Foundation type
Foundation depth
Foundation thickness
Enclosed space mixing volume
Air exchange rate
Building airflow rate
Building gauge pressure
Crack width
Crack total length
Crack location (illustrated in Figure B-1)
Surrounding fill: soil gas intrinsic permeability
Surrounding fill: total porosity
Surrounding fill: moisture content
One home
10 mx10 m
(100 m2= 1,076ft2)
Basement
Slab-on-grade
2.0 m (basement)
0.2 m (slab-on-grade)
0.15m
174m3
0.5 h'1
87 nf/h
5 Pa
0.001 m
39 m
Perimeter
No fill (native soil)
No fill (native soil)
No fill (native soil)
Multiple homes





0.25, 1 h'1
62.5,75, 150,200, 300 nf/h
-5, -2, 0, 1,2,5, 7, 20 Pa
No cracks
No cracks
Center of foundation
5E-1 1 m2
0.5
0.01
Source Assumptions
Source location
Source area
Source depth
Lateral distance from source to building
Groundwater table: the vapors
are on top of capillary fringe
(vapors originating from either
dissolved groundwater or NAPL
plume sources)
Infinite source
8 m bgs
0 (directly under building)
Vadosezone (soil)
Finite source
3, 5, 12, 18 m bgs
5-30 m
Contaminant Assumptions
Contaminant persistency
Vapor concentration at source
Diffusion coefficient in air
Diffusion coefficient in water
Diffusion coefficient in the crack area
Henry's law constant
Sorption coefficient to organic carbon
First-order biodegradation rate (A)
Contaminant vapor transport type
Recalcitrant
NA (recalcitrant)
3.17E-2m2/h
3.53E-6 nf/h
3.17E-2nY%
0.228 nfwater/nfvapor
60 (g/g0c)/(g/L3™ter)
NA (recalcitrant)
Steady state
Aerobically biodegradable
2-200 mg/L




600 (g/g0c)/(g/L3water)
0.018, 0.18, 1.8 IV1
Transient
                                                                           (continued)
                                        B-3

-------
Model Inputs and Assumptions
Appendix B
Input/Assumption
Baseline Value
Alternative Values Modeled
Soil Properties
Soil type/layers
Bulk density
Moisture saturation (water-filled porosity)
Total soil porosity
Mass fraction of organic carbon in the soil
Soil gas intrinsic permeability
Input/Assumption
Homogeneous, uniform sand
1,700kg/m3
20% (0.07 m3water/m3voids)
0.35 m voids/m Soii
0.001 (goc/gsoii)
1C'11 m2
High Moisture Layer
Sand with confining layers
(see properties below)



0.005 (goc/gsoii)

Barrier Layer
Confining Layer Properties (alternative condition)
Soil type
Bulk density
Pore water saturation
Soil gas intrinsic permeability
Total soil porosity
Silty sand
1,700kg/m3
60% (0.21 m3water/m3voids)
10-l3nf
0.35 m3voids/m3soii
Silty clay
1,700kg/m3
95% (0.38 m3water/m3voids)
10-l3nf
0.40 m3voids/m3soii
   The symmetrical scenarios domain includes only a quarter of the building footprint (5 m x 5 m footprint area) in the simulations.
                                                    B-4

-------
Model Inputs and Assumptions
                 Appendix B
                                           (a)
            10m
                                 9.75m
                                              9.75 m
                                               10m
                                           (b)
            10m
                                  9.75m
                           4.375 m
                                                10m
4.375 m
    Figure B-l. Plan view of the foundation crack distribution (dashed lines) used in the
         simulations for perimeter cracks (a) and center-of-foundation cracks (b).
                                          B-5

-------
Model Inputs and Assumptions                                                      Appendix B
                             [This page intentionally left blank.]
                                           B-6

-------
Document Development and Peer Review                             Appendix C
                        Appendix C
         Document Development and Peer Review
                            c-i

-------
Document Development and Peer Review                                            Appendix C
                            [This page intentionally left blank.]
                                           C-2

-------
Document Development and Peer Review                                          Appendix C



                                 Appendix C

             Document Development and Peer Review

This appendix provides the history of the development and review process for EPA 530-R-10-
003, Conceptual Model Scenarios for the Vapor Intrusion Pathway. The model simulations on
which this document was based were conducted by Dr. Lilian D.V. Abreu of ARCADIS U.S.,
Inc., using a 3-D model of vapor intrusion processes that she originally developed as a graduate
student of Dr. Paul Johnson at Arizona State University. Beginning in 2005, Dr. Abreu presented
model simulations in a series of EPA-sponsored vapor intrusion workshops, where she
demonstrated the power of her simulations in illustrating vapor intrusion processes. Based on the
responses to these workshops, EPA contracted with Dr. Abreu to develop and document a
comprehensive set of simulations to help vapor intrusion practitioners visualize vapor intrusion
phenomena. From 2007 through the summer of 2009, Dr. Abreu worked through document
development, editing, technical review, and response to comments with the vapor intrusion
guidance development team, including representatives from the following organizations with
experience and expertise in vapor intrusion and/or indoor air:

    •  U.S. EPA—13 staff from the Office of Solid Waste and Emergency Response, the Office
      of Superfund Remediation and Technology Innovation, the Office of Resource
      Conservation and Recovery, the Brownfields Office, four Office of Research and
      Development Laboratories, and two U.S. EPA Regions

    •  Contractors-Consultants—11 subject matter experts from Arizona State University,
      EnviroGroup Limited, GeoSyntec Consultants, Golder Associates, and RTI International

    •  State Agencies—4  expert practitioners/regulators from Kansas, New Jersey, and New
      York.

The remainder of this appendix describes the peer review of the model (including previous
publications) conducted before the document was developed, internal EPA review of the
document, and EPA's external peer review of the document and simulations it provides.

C.I  Prior Peer Review of the 3-D Model

The 3-D model, including its description and use, was the subject of Dr. Abreu's Ph.D.
dissertation and was subject to all reviews for doctoral degrees at Arizona State University. The
3-D model was also peer reviewed and published in several journals, which are listed in Section
C.3. In addition, the modeling results have been presented in several conferences and workshops,
which are listed in Section  C.4.

C.2  Internal EPA Review and EPA Peer Review

After initial review by the EPA members of the vapor intrusion guidance team, EPA's Vapor
Intrusion Forum (VIF) reviewed the document in 2009. For this review, the document was sent
to VIF, including members from EPA Regions, the Office of Solid Waste and Emergency
Response, and the Office of Research and Development.

-------
Document Development and Peer Review                                           Appendix C


From June to August 2009, the document was subjected to EPA's External Peer Review process,
where it was reviewed by four experts in the development and use of models for the vapor
intrusion pathway (Dan Gallagher, California Environmental Protection Agency; John Menatti,
Utah Department of Environmental Quality; Kelly Pennell, Brown University; and Frank
Swartjes, National Institute of Public Health and the Environment [RIVM], The Netherlands).
This peer review panel was selected to include the following expertise:

    •   Practical and theoretical understanding of the vapor intrusion pathway, including how
       volatile organic contaminants move and distribute in the subsurface (soil gas), indoor air,
       and outdoor air from dissolved and non-aqueous phase sources

    •   Experience in planning and interpreting site-specific vapor intrusion studies, including
       developing and refining conceptual  site models of the migration and distribution of
       volatile contaminants

    •   Expertise in modeling the vapor intrusion pathway or other environmental media using
       numeric simulations and 1-D to 3-D models and in applying and calibrating models using
       site-specific data.

Once external peer review comments had been received, Dr. Abreu and the vapor intrusion
guidance team developed responses  to comments and made final revisions to the document to
address them (from September to December 2009). From January through March 2010, the
document received final EPA management and legal review prior to its finalization as of March
31,2010.

C.3   3-D Model Peer-Reviewed Publications

Abreu, L.D.V. 2005. A Transient Three-dimensional Numerical Model to Simulate Vapor
       Intrusion into Buildings. UMI 3166060. Ph.D. Dissertation, Arizona State University,
       Tempe, AZ.

Abreu, L.D.V. and P.C. Johnson. 2005. Effect of vapor source-building separation and building
       construction on soil vapor intrusion as studied with a three-dimensional numerical model.
       Environmental Science & Technology 39(12)4550^1561.

Abreu, L.D.V. and P.C. Johnson. 2006.  Simulating the effect of aerobic biodegradation on soil
       vapor intrusion into buildings: Influence of degradation rate, source concentration, and
       depth. Environmental Science & Technology 40(7):2304-2315.

Abreu, L.D.V., R.A. Ettinger, and T. McAlary.  2009. Simulated vapor intrusion attenuation
       factors including biodegradation for petroleum hydrocarbons. Ground Water Monitoring
       and Remediation Journal 29(1): 105-117.

Abreu, L.D.V., R.A. Ettinger, and T. McAlary.  2009. Simulating the effect of aerobic
       biodegradation on soil vapor intrusion into buildings: Evaluation of low strength sources
       associated with dissolved gasoline plumes. API Publication 4775,  April. API:
       Washington, DC.
                                          C-4

-------
Document Development and Peer Review                                          Appendix C


C.4   3-D Model Work Presented at Conferences and Workshops

Abreu, L.D.V. 2010. Conceptual Model Scenarios (CMS) for the Vapor Intrusion Pathway.
       Final-Draft. Presented at the Twentieth Annual Association for Environmental Health
       and Sciences (AEHS) Meeting and West Coast Conference on Soils, Sediments, and
       Water, March 16, 2010. San Diego, CA.

Abreu, L.D.V., andR. Ettinger. 2009. Understanding the Conceptual Site Model for Vapor
       Intrusion into Buildings.  Presented at the U.S.EPA National Forum on Vapor Intrusion,
       January 12-13, 2009. Philadelphia, PA.

Abreu, L.D.V., R. Ettinger, and T. McAlary. 2009. Theoretical Overview of Vapor Intrusion
       Processes. Presented at the Air and Waste Management Association (AWMA) Specialty
       Conference: Vapor Intrusion. January 27-30, 2009. San Diego, CA.

Abreu, L.D.V., R. Ettinger, and T. McAlary. 2007. 3D Numerical Modeling to Assess Vapor
       Intrusion Screening Criteria for Petroleum Hydrocarbon Sites. Presented at the AWMA
       Specialty Conference—Vapor Intrusion: Learning from the Challenges. September 26-
       28, 2007. Providence, RI.

Abreu, L.D.V., R. Ettinger, and T. McAlary. 2007. Application of 3D Numerical Modeling to
       Assess Vapor Intrusion Screening Criteria for Petroleum Hydrocarbon Sites. Presented at
       the Seventeenth Annual AEHS Meeting and West Coast Conference on Soils, Sediments,
       and Water, March 19-22, 2007. San Diego, CA.

Abreu, L.D.V., P.C. Johnson, and T. McAlary. 2006. 3D Model Simulations and Implications to
       Near Building Sampling. Presented at the EPA/AEHS Vapor Intrusion Workshop, March
       16,2006. San Diego, CA.

Abreu, L.D.V., and P.C. Johnson. 2005. Modeling the Effect of Aerobic Biodegradation on
       Vapor Intrusion. Presented at the National Ground Water Association/American
       Petroleum Institute (NGWA/API) Petroleum Vapor Intrusion Workshop, August 17,
       2005. Costa Mesa, C A.

Abreu, L.D. V., and P.C. Johnson. 2005.  Vapor Intrusion: Lessons Learned Through Numerical
       Simulations. Presented at the EPA/AEHS Vapor Intrusion  Workshop, March 14-15,
       2005. San Diego, C A.

Johnson, P.C., and L.D.V. Abreu. 2004. Site-Specific Modeling in the Context of the OSWER
       Guidance? Presented at the EPA/UMass Modeling Vapor Attenuation Workshop,
       October 18-19, 2004. Amherst, MA.

Abreu, L.D.V., and P.C. Johnson. 2004. Learning Through the Simulations of Vapor Intrusion
       Scenarios. Presented at the U.S Department of Energy/Petroleum Environmental
       Research Forum (DOE/PERF) Hydrocarbon Vapor Workshop, January 27-29, 2004.
       Brea, CA.
                                         C-5

-------
Document Development and Peer Review                                          Appendix C


Johnson, P.C., and L.D.V. Abreu. 2003. Confusion? Delusion? What Do We Really Know About
       Vapor Intrusion? Presented at the Eighth Symposium in the Groundwater Resources
       Association's Series on Groundwater Contaminants: Subsurface Vapor Intrusion to
       Indoor Air: When is Soil and Groundwater Contamination an Indoor Air Issue?
       September 30, 2003. San Jose, CA.
                                         C-6

-------
Variables Index                                               Appendix D
                         Appendix D
                       Variables Index
                              D-l

-------
Variables Index                                                                    Appendix D
                             [This page intentionally left blank.]
                                            D-2



-------