EPA/600/R-13/250
                                                                           November 2013
         THE ENVIRONMENTAL TECHNOLOGY VERIFICATION
                                     PROGRAM ^
                                                   //
       ģEFA
ETV
  U.S. Environmental Protection Agency
                                                                   NSF International

                    ETV Joint Verification Statement
    TECHNOLOGY TYPE: UV DISINFECTION IN DRINKING WATER
    APPLICATION:        REMOVAL OF MICROBIAL CONTAMINANTS
    PRODUCT NAME:     ETS UV SYSTEM MODEL UVL-200-4
    VENDOR:             ENGINEERED TREATMENT SYSTEMS LLC
    ADDRESS:             9652 BEAVERLAND PARKWAY
                           BEAVER DAM, WISCONSIN
    PHONE:               877-885-4628
    WEBSITE:             HTTP://ETS-UV.COM
    EMAIL:               INFO@ETS-UV.COM
NSF International (NSF)  manages the Drinking Water  Systems (DWS)  Center under the U.S.
Environmental Protection Agency's (EPA) Environmental Technology Verification (ETV) Program. The
DWS Center recently evaluated the performance of the ETS UV System Model UVL-200-4 (UVL-200-
4). NSF performed all verification testing activities at its Ann Arbor, MI location.

EPA created the ETV Program to  facilitate the deployment of innovative or improved environmental
technologies through performance verification and dissemination of information.  The ETV Program's
goal is to further environmental protection by accelerating the acceptance and use of improved and more
cost-effective technologies. ETV seeks to  achieve this goal by providing high quality, peer-reviewed data
on technology performance to those involved in the design, distribution, permitting, purchase, and use of
environmental technologies.

ETV works  in partnership with recognized  standards and testing organizations, stakeholder groups
(consisting of buyers, vendor organizations, and permitters),  and with the full participation of individual
technology developers. The program evaluates  the performance of innovative technologies by developing
test plans that  are responsive to the needs of stakeholders, conducting  field or laboratory tests  (as
appropriate), collecting and analyzing  data, and preparing  peer-reviewed  reports. All evaluations  are
conducted according to rigorous quality assurance  protocols to ensure that data of known and adequate
quality  are generated and that the results are defensible.

ABSTRACT

The ETS UV System Model UVL-200-4 was tested to validate the UV dose delivered by the system using
biodosimetry and a set line approach. The set line for 40 mJ/cm2 Reduction  Equivalent Dose (RED) was
based on validation testing at three (3) set  points. A  set point is defined at a single flow rate and irradiance
NSF 13/40/EPADWCTR  The accompanying notice is an integral part of this verification statement.        November 2013
                                          VS-i

-------
output that delivers the targeted UV dose. The results of the three set point tests were used to develop the
setline that defined the maximum flow rate and minimum irradiance output required to ensure that a 40
mJ/cm2  RED is achieved. The microorganism used for the validation was  MS2 coliphage virus. ETS
selected flow rates for testing of 15, 20, and 25 gpm based on the unit design and preliminary screening
tests. The lowest irradiance tested was 7.0 W/m2 which occurred with full power to the unit and a feed
water Ultraviolet Transmission (UVT) of 79%.

The measured RED was  adjusted for RED  bias and uncertainty to determine the validation factor for
calculating log inactivation of Cryptosporidium. The  validation factor and  validated  dose  calculations
were performed as specified in the USEPA Ultraviolet  Design Guidance Manual (UVDGM-2006). Based
on the results of these tests and the  calculated validation factor, the UVL-200-4 achieved a minimum of
4.0 log  reduction credit for Cryptosporidium at all of the test flow rates and corresponding irradiance
levels. Some regulatory agencies have established a standard for spray parks and other applications based
on a validated dose  (REDVai) of 40 mJ/cm2 based on MS2, as the pathogen.  The calculation of the
validation factor for a validated dose based on MS2 was performed using BRED set equal to 1.0. The UVL-
200-4 achieved a REDVai of 40 mJ/cm2 at all set points tested.

TECHNOLOGY DESCRIPTION

The UVL-200-4 uses one  (1) low pressure UV lamp and one intensity sensor mounted in a stainless steel
flow chamber. The inlet pipe size is 2 inch diameter, the unit is designed for an operating pressure of 145
psi, and operating power consumption is < 200 W. The low pressure lamp has a rated lamp life of 12,000
hours. The sensor is a UV-Technik SUV20.1 A2Y2C  unit with a measuring field angle of  160  degrees
and measuring range of 0 to 20 W/m2.  The system has a control panel that provides data on the lamp
condition, operating  hours, irradiance measured  by the sensor, and other operating conditions.  The
operating manual provides schematics and tables with parts, dimensions and other specifications for the
reactor, the sensors, the lamps and the quartz  sleeves.

VERIFICATION TESTING DESCRIPTION

Test Site and Equipment
The verification test was conducted  using a full scale unit installed at the NSF Engineering Laboratory in
Ann Arbor Michigan. The water source for this test was City of Ann Arbor Michigan municipal drinking
water that was de-chlorinated using activated carbon.  Lignosulfonic Acid (LSA) was used to lower the
UV transmittance (UVT)  for the full power low UVT test runs. UVT was measured continuously using
an in-line UVT meter (calibrated daily) to confirm that proper UVT was attained.

NSF used a test rig and system setup that is designed to conform to the specifications described in the
UVDGM-2006.  The UV reactor  inlet and outlet connections  were installed according  to the ETS
installation and assembly instructions.  Two 90 degree elbows were attached directly to the inlet and
outlet of the system to eliminate stray UV light. The feed water pump was a variable speed pump. Flow
rate was controlled by adjusting the power supplied to the pump and by a control valve. A turbine water
flow meter was used to monitor flow rate. The meter was calibrated and achieved an accuracy of  + 1.6%
over the range of flow rates. A chemical feed pump (injector pump)  was used to inject MS2 coliphage
upstream of an inline static mixer. The inline mixer ensured sufficient mixing of the microorganism prior
to the influent sampling port, which was located upstream of the 90°  elbow at the inlet to the unit.  The
effluent sampling port was located  downstream of the 90° elbow and a second inline  static mixer.  The
sampling location met the UVDGM-2006 requirement to ensure good mixing of the treated water prior to
the effluent sampling port. A power platform that measures amperage, volts, watts, and power factor was
used to monitor power use by the test unit. The unit was wired into the platform and power consumption
was recorded for each test run.
NSF 13/40/EPADWCTR   The accompanying notice is an integral part of this verification statement.        November 2013
                                             VS-ii

-------
Methods and Procedures
The  tests  followed the procedures  described in the Test/Quality Assurance  Plan for the ETS UV
Ultraviolet (UV) System Model UVL-200-4, Low Pressure Lamp, September 2010 (TQAP).  The TQAP
was adapted from Generic Protocol for Development of Test/Quality Assurance Plans for Validation of
Ultraviolet (UV) Reactors, 7/2010. This generic protocol is based on the USEPA's UVDGM-2006. The
TQAP was updated based on the GP of August 2011 prior to the start of the validation test.

The  approach used to validate UV  reactors was based on biodosimetry  which determines the log
inactivation of a challenge microorganism  during  full-scale  reactor testing for specific  operating
conditions of flow rate, UV transmittance (UVT), and UV intensity (measured by the duty sensor). MS2
coliphage ATCC 15597-B1 was used in collimated beam bench scale testing and for the full-scale reactor
dose validation tests.  A dose-response equation for the challenge microorganism (MS2 coliphage for this
test) was determined using a collimated beam bench-scale test. The observed log-inactivation values from
full-scale testing were input into the collimated beam derived-UV dose-response equations to estimate a
measured "Reduction Equivalent Dose (REDmeas)". The REDmeas  value was adjusted for uncertainties and
biases to produce the validated dose of the reactor for the specific  operating conditions tested.

The UV lamp was new and therefore the system was operated for 100 hours with the lamps turned on at
full power prior to the start of the test.

VERIFICATION OF PERFORMANCE

System Operation
Each  set point represented a given  flow rate - irradiance  pair with testing under two conditions,(l)
lowered UVT-max power and (2)  high UVT-reduced power. The first test condition involved reducing
the UVT while operating the UV system at full power until the  UV intensity measured by the unit UV
sensor equaled the target  UV intensity set point.  The  second test condition was  run with high UVT and
with the power reduced until the unit UV intensity measured by the sensor was equal to the target UV
intensity set point. Three target flow rates - irradiance set points  (15 gpm - 7 W/m2; 20 gpm - 11 W/m2;
25 gpm -  13 W/m2) were tested for the set line with each condition being performed in duplicate. The
irradiance targets were based on expected irradiance at UVT's of 79%, 90%, and 94%.

The validation tests were run on two days, June 20 and 21, 2012.  The first day of testing was dedicated to
the test conditions and duplicate runs  where the UVT of the feed water was lowered to the target levels
(<79%,  <90%, and <94%) and the lamps were operated at full  power. The second day of testing was
dedicated to the test conditions and duplicates where high UVT feed water (97%) was used and the lamp
power was reduced to achieve the  target intensity level. Collimated beam tests were run in duplicate on
both test days and included minimum UVT water (79%) on Day 1 and maximum UVT water (97%) on
Day 2. For this validation test, there were two sets of duplicate collimated beam test data, one at low UVT
and one at high UVT.

Test Results
Sensor Assessment
The test unit duty sensor  was evaluated according to the UV sensor requirements  in the UVDGM-2006
prior to the verification testing. All UV intensity sensors (the duty and two reference sensors) were new
sensors  designed according to the DVGW guideline W 294 (June,  2006) and the ONORM M5873-1
standard (March, 2001). Evidence of calibration of the sensors, traceable to a standard of the Physikalisch
Technische Bundesanstalt (PTB)  in Braunschweig, was  provided by ETS as provided to  them by the
sensor manufacturer (UV-TECHNIK).
NSF 13/40/EPADWCTR   The accompanying notice is an integral part of this verification statement.        November 2013
                                             VS-iii

-------
The same duty sensor was used for monitoring intensity (irradiance) for all test runs. The control panel
provided direct readings of intensity  in W/m2. The duty sensor was compared  against two reference
sensors before and after the validation test runs. These data demonstrate that the duty sensor was within
the range of 0.1% to 0.7% of the average of the two reference sensors, which meets the QCgoal of <10%.
The two reference sensors showed a variance of 2.7% at 100% power and 22.7% to 3.0% at 60% power.

Set Line for 40 m J/cm2 REDmeaS
The three set points selected for this validation all achieved a REDmeas of 40 mJ/cm2 based on MS2, which
was the target minimum REDmeas for developing the set line. Figure 1 shows the  set line. The unit was
validated for a minimum REDmeas of 40 mJ/cm2 for any flow rate and intensity combination above and to
the left of the set line. The maximum flow rate demonstrated was 24.9 gpm. A UV system cannot operate
above the highest validated flow rate and claim a 40 mJ/cm2 REDmeas. The lowest intensity demonstrating
a REDmeas of 40 mJ/cm2 was 7.0 W/m2.  A  UV  system cannot operate below the lowest validated
irradiance and claim a 40 mJ/cm2 REDmeas. The three set points used to develop at set line were:

Set Point 1-14.8 gpm;   7.0 W/m2
Set Point 2-19.9 gpm; 11.0 W/m2
Set Point 3-24.9 gpm; 12.8 W/m2
              4.0
              2.0
              0.0
                                       10         15         20
                                          Flow Rate (gpm)
                                                                       25
                                                                                  30
Figure 1. Set line for 40 mJ/cmz REDmeas for ETS UV Model UVL-200-4.

Deriving the Validation Factor and Log Credit for Cryptosporidium
As described in UVDGM, several uncertainties and biases are involved in using experimental testing to
define  a  validated  dose  and validated  operating conditions.  The  validation  factor  (VF)  for
Cryptosporidium was determined quantitatively to account for key areas of uncertainty and variability.
The equation for the VF is:
               where:
                                            x[l+(UVai/100)]
                      VF = Validation Factor;
                      BRED = RED bias factor;
                      UVai = Uncertainty of validation expressed as a percentage.
NSF 13/40/EPADWCTR   The accompanying notice is an integral part of this verification statement.
                                            VS-iv
November 2013

-------
The highest BRED value found among the replicates at a given set point was selected for the BRED value for
use in the VF calculation per the UVDGM-2006. UVai was calculated based on the Us (uncertainty of
sensor value), UDR (uncertainty of the fit of the dose-response curve and USp (uncertainty of set-point).
The QC requirement that the duty sensor measurements should be within 10% of the average of two or
more  reference sensors eliminates the need to calculate the Us factor per the UVDGM-2006. The UDR
results for low and high UVT waters  (26.73% and 18.14%, respectively) were less  than 30%, and
therefore UDR was not used in calculating UVai for the test runs.

The USp and UDR factors were used for calculating UVai perthe equations:

                                  Uvai = (USP2+UDR2)1/2 ifUDR>30%
                                   Uval =  USp         if UDR <30%

After  establishing the validation factor (VF), the validated dose was calculated as:

                                   Validated dose = RED/VF

All of the set points achieved a validated dose that showed a minimum of a 4-log reduction credit for
Cryptosporidium. The  set line for a minimum 3.0 log reduction credit for Cryptosporidium (also 4.0 log
reduction credit) is shown in Figure 2. This set line was based on the following set points:

Set Point 1-14.8 gpm;  7.0 W/m2
Set Point 2-19.9 gpm; 11.0 W/m2
Set Point 3-24.9 gpm; 12.8 W/m2

Some regulatory agencies, such as the New York Department of Health, have established a standard for
spray  parks and other applications based on a validated dose (REDVai) of 40 mJ/cm2 based on MS2, as the
pathogen. The calculation of the validation factor for a validated dose based on MS2 was performed using
BRED  set equal to 1.0 because the pathogen selected was the same as the test organism, so there was no
bias correction. The REDVai based on MS2  was calculated for each test run. All of the set point test runs
achieved a 40 mJ/cm2 validated dose based on MS2. The set line for a minimum  validated dose of 40
mJ/cm2 was the same as for the 3.0 and 4.0 log reduction credit for Cryptosporidium, as the set points wer
the same. Figure 2 represents the set line for a minimum REDVaiof 40 mJ/cm2.

QUALITY ASSURANCE/QUALITY CONTROL

The NSF QA Department performed a QA review of the analytical data. A complete description of the
QA/QC procedures is provided in the verification report.
NSF 13/40/EPADWCTR   The accompanying notice is an integral part of this verification statement.         November 2013
                                             VS-v

-------
           5J  6.0
               4.0
               2.0
               0.0
                                            10          15          20
                                                Flow Rate (gpm)
                                                                                 25
                                                                                             30
Figure 2. Set Line for Minimum 3-log and Minimum 4.0 log Cryptosporidium Inactivation for ETS
\JVModelUVL-200-4.

    Original signed by Cynthia Sonich-Mullin on     Original signed by David Purkiss on
    01/23/2014
                                 01/16/2014
    Cynthia Sonich-Mullin               Date
    Director
    National Risk Management Research
    Laboratory
    Office of Research and Development
    United States Environmental Protection
    Agency
                                                                      Date
                                Vice President
                                Water Systems
                                NSF International
    NOTICE: Verifications are based on an evaluation of technology performance under specific, predetermined criteria
    and the appropriate quality assurance procedures.  EPA and NSF make no expressed or implied warranties as to the
    performance of the technology and do not certify that a technology will always operate as verified.  The end-user is
    solely responsible for  complying with any  and all applicable federal,  state, and local requirements.  Mention of
    corporate names, trade  names, or commercial products does not constitute endorsement or recommendation for use of
    specific products.  This report is not an NSF Certification of the specific product mentioned herein.
        Availability of Supporting Documents
        Copies of the test protocol, the verification statement, and the verification report (NSF  report  # NSF
        10/33/EPADWCTR) are available from the following sources:
        1.   ETV Drinking Water Systems Center Manager (order hard copy)
            NSF International
            P.O. Box 130140
            Ann Arbor, Michigan 48113-0140
        2.   Electronic PDF copy
            NSF web site: http://www.nsf.org/info/etv
            EPA web site: http://www.epa.gov/etv
NSF 13/40/EPADWCTR
The accompanying notice is an integral part of this verification statement.
                           VS-vi
November 2013

-------