EPA Guidance on EGA Marine Fuel
vvEPA
Jn led States
Environmental Proloclion
Agency

-------
        EPA  Guidance on EGA Marine Fuel
                        Assessment and Standards Division
                       Office of Transportation and Air Quality
                       U.S. Environmental Protection Agency
       Disclaimer:

       This document puts EPA regulatory provisions in context with plain language.
       Nothing in this document revises or replaces any regulatory provisions in the
       Rule, any other part of the Code of Federal Regulations, the Federal Register,
       the Act to Prevent Pollution from Ships or the Clean Air Act.
United States
Environm«nl.»l ProlecliQn
Agency
EPA-420-B-14-097
December 2014

-------
                   EPA Guidance on EGA Marine Fuel

MARPOL Annex VI requires ocean-going vessels to use fuel with a maximum sulfur
level of 1,000 ppm in Emission Control Areas beginning January 1, 2015.

Background:

       Annex VI is an annex to the International Convention on the Prevention of
       Pollution from Ships, which is generally known as MARPOL, short for "marine
       pollution". The United States became a party to MARPOL Annex VI in 2008.
       MARPOL Annex VI requirements and authorities are implemented in the United
       States through the Act to Prevent Pollution from Ships (APPS).  APPS makes the
       fuel sulfur standards of MARPOL Annex VI Regulation  14 applicable to U.S.-
       flagged vessels wherever located and to foreign-flagged vessels  operating in the
       United States navigable waters or the United States Exclusive Economic Zone
       (EEZ).  See Section 1902 of APPS and 40 CFR 1043.10(b).
       EPA is implementing a coordinated strategy to address emissions from ships that
       affect U.S. air quality. EPA's coordinated strategy  includes regulations
       promulgated under the Clean Air Act and, regulations to  codify  and implement
       the requirements of MARPOL Annex VI Regulation 13,14 and  18, and the
       designation of U.S. coasts as an Emission Control Area (EGA) through an
       amendment to MARPOL Annex VI. The regulations that EPA published to
       implement this coordinated strategy can be found at 40 CFR Parts 80, 1042 and
       1043.  See EPA's Category 3 Marine Rule (75 FR 22896, April  30, 2010 [link to:
       http://www.gpo.gov/fdsys/pkg/FR-2010-04-30/pdf/2010-2534.pdj}}.
   -   40 CFR Part 80 requires parties who produce and distribute EGA marine fuel to
       comply with a number of requirements before January 1,  2015, to ensure that
       ECA marine fuel meets the 0.10% (1,000 ppm) sulfur standards. The Part 80
       regulations include a phase in schedule that requires refiners and importers to
       meet the 1,000 ppm sulfur standard beginning June 1, 2014, and all ECA marine
       fuel in the fuel distribution system to meet the 1,000 ppm sulfur standard by
       December 1, 2014.
   -   In addition, "ECA marine fuel" in 40 CFR 80.2(ttt), is defined, in part, as fuel
       used, intended for use, or made available for use in  Category 3 marine vessels
       while the vessels are operating within an ECA. Category 3 (or "C3") marine
       vessels are defined  in 40 CFR 80.2(uuu) as vessels propelled by engines meeting
       the definition of "Category 3" in 40 CFR 1042.901—reciprocating marine
       engines with a displacement at or above 30.0 liters per cylinder.  Fuel for marine
       engines that are not Category 3 engines have more stringent sulfur requirements.
       This guidance is designed to assist with compliance with  these important
       requirements as suppliers of ECA marine fuel and vessel  owners and operators
       transition to the 2015 standard.

-------
The following table shows the Annex VI Worldwide and EGA fuel sulfur requirements
and EPA's fuel sulfur limits for C3 marine vessels:
Annex VI and C3 Marine Rule Maximum Sulfur Limits (ppm)

Worldwide fuel sulfur content (" any fuel oil used
onboard ships" per Annex VI Regulation 14.1)a
Sulfur content (per Annex VI Regulation 14.4) of fuels
used in EGAs — including the North American EGA
2014
35,000
10,000b
2015
35,000
1,000
2020
5,000
1,000
a- All Annex VI sulfur standards begin on January 1 of a given year, unless otherwise noted.
b- The amendments adopting the North American EGA entered into force on August 1, 201 1, and the
10,000 ppm fuel requirement in the North American ECA went into force on August 1, 2012.
The following table sets forth the implementation schedule for the 1,000 ppm maximum
sulfur standard applicable to ECA marine fuel (per 40 CFR 80.510(k) and 80.51 l(b)(9)):
ECA Marine Schedule
Refiners and Importers
All downstream locations other than retail
outlets and wholesale purchaser-consumers
(WPCs)
Retail outlets and WPCs
All locations
June 1, 2014
August 1, 2014
October 1, 2014
December 1, 2014
Refiners of ECA marine fuel include any facility where ECA marine fuel is produced
from crude oil or where blendstocks are combined to produce ECA marine fuel.

Importers of ECA marine fuel are any person who imports ECA marine fuel into the
United States.

Downstream locations include:
    •   petroleum product terminals that store ECA marine fuel prior to delivery to a
       retailer or WPC, and
    •   conveyors of ECA marine fuel to product terminals or to retailer/WPC facilities
       via tank truck, rail car, barge, marine tanker, pipeline, or other means.

Retail outlets of ECA marine fuel include any facility and/or transport vessel that deliver
ECA marine fuel to refuel a marine vessel.

A Wholesale Purchaser-Consumer of ECA marine fuel includes any facility owned by an
operator of marine vessels required to use ECA marine fuel from which the  operator
draws ECA marine fuel for its own vessel refueling operations (e.g., a vessel fleet).
All locations in the fuel distribution system must meet the 1,000 ppm ECA marine fuel
sulfur standard by December 1, 2014.

-------
Liability and Violations:

Under the 40 CFR Part 80 EGA marine fuel regulations, any person in the fuel
distribution system who controls the facility where a violation of the 1,000 ppm EGA
marine fuel sulfur standard is found may be liable for the violation.  Anyone who
produced or distributed this fuel is also presumed liable for the violations unless and until
they can establish an affirmative defense. The EGA marine fuel regulations also
explicitly prohibit any person from causing another person to violate the 1,000 ppm EGA
marine fuel sulfur standards.  See 40 CFR 80.612.

40 CFR 80.613 states that anyone deemed liable for a violation must establish the
following to meet an affirmative defense:
    1.   Demonstrate that they did not cause the violation.
    2.   Show that product transfer documents (PTDs) exist establishing that the EGA
       marine fuel was in compliance while under their control; and
    3.   Show that they conducted a quality assurance sampling and testing program
       (except as noted below).

Since  anyone in the EGA marine fuel distribution system may be held liable for
downstream violations of the 1,000 ppm sulfur standard, EPA encourages everyone in the
EGA marine fuel distribution system to implement robust quality assurance programs to
assure that the fuel they are producing, transporting, and selling complies with the 1,000
ppm EGA marine sulfur standard and is not contaminated with higher sulfur fuels. While
retailers and WPCs are not required to conduct sampling and testing programs under 40
CFR 80.613, EPA highly encourages these parties to implement a quality assurance
program to demonstrate that they did not cause the violation (such a program could
include voluntary sampling and testing, retention of samples used for bunker delivery
notes, etc.).
Sampling and Testing Requirements:

For purposes of compliance with the 40 CFR Part 80 EGA marine fuel regulations, per 40
CFR 80.580 and 80.581, refiners and importers are required to sample and test each batch
of EGA marine fuel using ASTM D2622 or another authorized test method to determine
compliance with the 1,000 ppm sulfur limit prior to the fuel  leaving the refinery or import
facility.

For purposes of compliance with MARPOL Annex VI, Regulation 18.8.1, APPS and
implementing regulations at 40 CFR Part 1043, for delivery of fuel to certain vessels, a
sample of the fuel must be taken during bunkering of fuel oil and retained on the vessel
for at least 1 year from the date of delivery. The sample must be taken in accordance
with MEPC. 96(47) "Guidelines for the Sampling of Fuel Oil for Determination of
Compliance with Annex VI of MARPOL 73/78" and must comply with the fuel sulfur

-------
standards using the ISO 8754 test method. The sample must be sealed and signed by the
supplier's representative and the master or officer in charge of the bunker operation on
completion of the bunkering operation. If analysis of the sample is required, per
Regulation 18.8.2, the analysis must be done in accordance with the verification
procedure in Annex VI Appendix VI.
Product Transfer Documents and Bunker Delivery Notes:

Product Transfer Documents—
Per 40 CFR 80.590, anyone who produces and/or distributes EGA marine fuel must use
and maintain PTDs for all custody transfers of the fuel, except when the fuel is being
dispensed into marine diesel engines (or vessel fuel storage, settling, or service tanks for
the main engine); but see below for the requirements for bunker delivery notes, which
may apply. PTDs must contain the following information:
    •  The names and addresses of the party transferring the fuel ("transferor") and who
       the fuel is being transferred to ("transferee").
    •  The volume of fuel being transferred.
    •  The location of the fuel at the time of the transfer.
    •  The date of the transfer.
    •  The sulfur standard the transferor claims that the fuel meets (i.e.,  1,000 ppm).
    •  For terminal operators and all parties upstream, the facility registration numbers
       of the parties transferring and receiving the fuel.
    •  The following statement: "1,000  ppm sulfur (maximum) EGA  marine  fuel. For
       use in Category  3 marine vessels only. Not for use in engines not installed on C3
       marine vessels."

Bunker Delivery Notes—
For purposes of compliance with MARPOL Annex VI Regulation 18.9, APPS and 40
CFR Part 1043, fuel suppliers must provide bunker delivery notes (BDN) to certain
vessel operators with EGA marine fuel. BDNs must be maintained by both the retailer
and by the owner/operator of the vessel. (See MARPOL Annex VI Regulation 18 and 40
CFR 1043 for more information on bunker delivery notes.)  Bunker delivery notes must
contain the following information:
    •  The name and EVIO number of the vessel receiving the fuel.
    •  Port (or description of the location, if the delivery does not take place at a port).
    •  Date the fuel is delivered to the vessel (or the date on which the delivery begins, if
       the delivery begins on one day and ends on a different day).
    •  Name,  address, and telephone number of fuel supplier.
    •  Fuel type and designation under 40 CFR part 80.
    •  Quantity, in metric tons.
    •  Density at 15 °C, in kg/m3.
    •  Sulfur content, as tested in accordance with ISO 8754:2003, in weight percent.
    •  A signed statement by an authorized representative of the fuel supplier certifying
       that the fuel supplied conforms to Regulations 14.1 or 14.4 and 18.3 of Annex VI

-------
       consistent with its designation, intended use, and the date on which it is to be
       used.  This statement in a BDN is not required, with respect to Regulations 14.1
       and 14.4, if the vessel is not subject to fuel sulfur standards of Regulation 14 of
       Annex VI pursuant to a Regulation 3 or Regulation 4 permit or waiver.
       Per Regulation 18.8.1 of Annex VI, bunker delivery notes shall be accompanied
       by a sample of the fuel. The sample must be sealed and signed by a
       representative and the master or officer in charge of the bunker operation, and
       must be retained on the ship for at least 1 year from the date  of delivery.
Registration, Reporting and Recordkeeping Requirements:

Refiners and importers of EGA marine fuel are required to register with EPA, and must
keep records showing the batch volume, the batch number, the date of production or
import, and records designating the batch as EGA marine fuel meeting the 1,000 ppm
sulfur standard.

All parties who produce, import, or distribute (including retailers and WPCs) EGA
marine fuel must keep copies of PTDs, records relating to sampling and testing, and
records relating to actions that the party has taken to stop the sale or distribution of EGA
marine fuel that does not meet the standards and actions that the party has taken to
identify the cause of the noncompliance and prevent future violations. Records must be
kept for 5 years.

Bunker delivery notes must be retained for 3 years, and readily available for inspection at
all times during those same 3 years.

See 40 CFR 80.597(c), 80.580, 80.581, 80.583-80.586, 80.602, and 1043.80.

-------
Related Guidance and Links:

•  Regulations:
   o     40 CFR Part 80: Regulation of Fuels and Fuel Additives
   o     40 CFR Part 1042: Control of Emissions From New and In-Use Marine
         Compression-Ignition Engines and Vessels
   o     40 CFR Part 1043: Control of NOx, SOx, and PM Emissions from Marine
         Engines and Vessels Subject to the MARPOL Protocol

   •  Frequently Asked Questions: North American Emission Control Area (EGA) U.S.
      Coast Guard Office of Commercial Vessel Compliance

   •  Guidance on the Non-Availability of Compliant Fuel Oil for the North American
      Emission Control  Area (EGA)

   •  EPA "Ocean Vessels and Large Ships" webpage

   •  EPA Office of Enforcement and Compliance Assurance: MARPOL Annex VI
      Information webpage

   •  U. S. Coast Guard  Homeport MARPOL Annex VI webpage

-------