EPA/625/R-96/010a
    Compendium of Methods
    for the Determination of
      Inorganic Compounds
         in Ambient Air
  Compendium Method IO-3.1

SELECTION, PREPARATION
   AND EXTRACTION OF
     FILTER MATERIAL
    Center for Environmental Research Information
      Office of Research and Development
      U.S. Environmental Protection Agency
          Cincinnati, OH 45268

             June 1999

-------
                                      Method 10-3.1

                                    Acknowledgments

This Method is a part of Compendium of Methods for the Determination of Inorganic Compounds in Ambient
Air (EPA/625/R-96/01 Oa), which was prepared under Contract No. 68-C3-0315, WA No. 2-10, by Midwest
Research Institute  (MRI), as a subcontractor  to Eastern Research Group,  Inc.  (ERG), and under the
sponsorship of the U.S. Environmental Protection Agency (EPA). Justice A. Manning, John 0. Burkle, Scott
Hedges, Center for Environmental Research Information (CERI), and Frank F. McElroy, National Exposure
Research Laboratory (NERL),  all in the EPA Office  of Research and Development, were responsible for
overseeing the preparation of this method.  Other support was provided by the following members of the
Compendia Workgroup:

    •   James L.  Cheney, U.S. Army Corps of Engineers, Omaha, NE
         Michael F. Davis, U.S. EPA, Region 7, KC, KS
    •   Joseph B. Elkins Jr., U.S. EPA, OAQPS, RTF, NC
    •    Robert G. Lewis, U.S. EPA,  NERL, RTF, NC
    •   Justice A. Manning, U.S.  EPA, ORD, Cincinnati, OH
    •    William A. McClenny, U.S. EPA, NERL, RTF, NC
    •    Frank F. McElroy, U.S. EPA, NERL, RTF, NC
    •    William T. "Jerry" Winberry, Jr., EnviroTech Solutions,  Gary, NC

This Method is the result of the efforts  of many individuals.  Gratitude goes to each person involved in the
preparation and review of this methodology.
Author (s)
        Avie Mainey, Midwest Research Institute, Kansas City, MO
        William T. "Jerry" Winberry, Jr., EnviroTech Solutions, Gary, NC
Peer Reviewers
        David Brant, National Research Center for Coal and Energy, Morgantown, WV
        John Glass, SC Department of Health and Environmental Control, Columbia, SC
        Jim Cheney, U.S. Army Corps of Engineers, Omaha, NE
        Dewayne Ehman, Texas Natural Resource Conservation Committee, Austin, TX
        Gary Wester, Midwest Research Institute, Kansas City, MO
        Lauren Drees, U.S. EPA, NRMRL, Cincinnati, OH
                                       DISCLAIMER

This Compendium has been subjected to  the Agency's peer and administrative review, and it has
been approved for publication as an EPA document. Mention of trade names or commercial products
does not constitute endorsement or recommendation for use.

-------
                                        Method IO-3.1
                            Selection, Preparation and Extraction of
                                        Filter Material

                                    TABLE OF  CONTENTS
1.   Scope	     3.1-1
2.   Applicable Documents	     3.1-1
    2.1   ASTM Documents  	     3.1-1
    2.2   Other Documents  	     3.1-2
3.   Apparatus  	     3.1-2
    3.1   Equipment For Gravimetric Analysis	     3.1-2
    3.2   Microwave Digestion Apparatus and Materials	     3.1-2
    3.3   Hot Acid Extraction Apparatus and Materials	     3.1-3
4.   Filter Medium Selection	     3.1-4
    4.1   Introduction	     3.1-4
    4.2   Visual Filter Inspection  	     3.1-5
5.   Gravimetric Determination	     3.1-6
    5.1   Introduction	     3.1-6
    5.2   High Volume Filter Weighing Procedure	     3.1-6
    5.3   Dichotomous and Partisol® Filter Weighing Procedure	     3.1-8
    5.4   Transport of Filters	    3.1-11
6.   Extraction of Glass Fiber Filters in Preparation for Metal Analysis	    3.1-11
    6.1   Introduction	    3.1-11
    6.2   Microwave Extraction Procedure	    3.1-11
    6.3   Hot Acid Extraction Procedure  	    3.1-15
                                              in

-------
[This page intentionally left blank]
                IV

-------
                                       Chapter IO-3
                            CHEMICAL SPECIES ANALYSIS
                                             OF
         FILTER-COLLECTED SUSPENDED PARTICULATE MATTER (SPM)

                                       Method IO-3.1
                   SELECTION, PREPARATION AND EXTRACTION OF
                                    FILTER MATERIAL
1. Scope

1.1 This methodology consists of (1) filter media selection, (2) numbering and pre-field tare weighing of
filters, (3) post-field final weighing of filters, (4) microwave or hot acid extraction, and (5) analysis for metal
analysis by ICP, FAA, ICP/MS or GFAA.

1.2 Pre-field filters are conditioned in a room of constant humidity and temperature and are gravimetrically
tared. After air samples have been collected, the filters are returned to the laboratory and conditioned as
before and weighed.  The final filter weight minus the tare weight is calculated.  The procedure for the
weighing of filters is based on 40 CFR 50, Appendix B,  entitled "Reference Method for the Determination
of Suspended Matter in the Atmosphere (High-Volume Method)."

1.3 After the post-field filter final weights have been obtained, the filter is subsampled by cutting a filter strip
consisting of one-ninth of the overall filter and digested using a microwave or hot acid extraction technique;
these extracts are then analyzed by one of many analytical techniques.  The results are multiplied by a factor
of 9 to obtain the actual total p.g of each metal found on the entire 8" x 10" filter. Based upon the analysis
of a blank filter, background metal concentration may be subtracted from the total metal concentration to get
a net value. Therefore, the analytical results represent the total p.g found on the 8" x 10" filter but  do not
represent the volume of air sampled.

1.4 Sectioning the filter for extraction is based  on 40CFR50, Appendix B entitled "Determination of Lead
in Suspended Particle Matter Collected From Ambient Air." The procedure for the microwave extraction is
based on a method developed by EPA entitled Microwave Extraction of Glass-Fiber Filters,  as identified in
Section 2.2. This procedure has been modified for extracting quartz fiber filters.
2. Applicable Documents

2.1 ASTM Documents

   •   D4096 Application of the High Volume Sample Method for Collection and Mass Determination of
       Airborne Particle Matter.
   •   D1356 Definition of Terms Related to Atmospheric Sampling and Analysis.
   •   D135 7 Practice for Planning the Sampling of the Ambient Atmosphere.
   •   D2986 Method for Evaluation of Air Assay Media by the Monodisperse DOP (Dioctyl Phthalate)
       Smoke Test.
June 1999             Compendium of Methods for Inorganic Air Pollutants             Page 3.1-1

-------
Method IO-3.1                                                                   Chapter IO-3
Filter Material                                                               Chemical Analysis

2.2 Other Documents

   •   U. S. Environmental Protection Agency, Quality Assurance Handbook for Air Pollution Measurement
       Systems, Volume I: A Field Guide for Environmental Quality Assurance,  EPA-600/R-94/038a.
   •   U. S. Environmental Protection Agency, Quality Assurance Handbook for Air Pollution Measurement
       Systems, Volume II: Ambient Air Specific Methods (Interim Edition), EPA-600/R-94/038b.
   •   Reference Method for the Determination of P'articulate Matter in the Atmosphere, Code of Federal
       Regulations (40 CFR 50, Appendix]).
   •   Reference Method for the Determination of Suspended Particulates in the Atmosphere (High Volume
       Method), Code of Federal Regulations (40 CFR 50, Appendix B).
   •   Reference Method for the Determination of Lead in Suspended Particulate Matter Collected from
       Ambient Air, Federal Register 43 (194): 46258-46261.
   •   U. S.  Environmental Protection Agency, Microwave Extraction of Glass Fiber Filters, Method
       Research and Development Division, RTF, NC 1989.
3. Apparatus

3.1 Equipment For Gravimetric Analysis

   3.1.1 Controlled Temperature.  Temperature between 15 and 30°C with less than ±2°C variation
during equilibration period.
   3.1.2 Controlled Humidity. Less than 50% relative humidity, constant within ±5%
   3.1.3 Analytical Balance. Sensitive to 0.1 mg, with weighing chamber designed to accept an unfolded
20.3x25.4 cm (8" x 10") filter.
   3.1.4 Area Light Source. Similar to X-ray film viewer to backlight filters for visual inspection.
   3.1.5 Numbering Device.  Capable of printing identification numbers on the filters before they are
placed in the filter conditioning environment if not numbered by the supplier.
   3.1.6 Hygrothermograph.  Capable of recording temperature and relative humidity in the weighing
room.

3.2 Microwave Digestion Apparatus and Materials

   3.2.1 Microwave Digestive System and Capping Station.  With programmable power settings up to
600 watts, best source.

[Note: Commercial kitchen or home-use microwave should NOT be used for digesting samples.  The oven
cavity must be corrosion resistant and well ventilated.  All electronics must be protected against corrosion
for safe operation.]

   3.2.2 PFA Teflon® Digestion Vessels.  Capable of withstanding pressures of up to 120 psi. Pressure
vessels capable of controlled pressure relief at pressures exceeding 120 psi (60-120 mL capacity), best
source.
   3.2.3 Teflon® PFA Overflow Vessel.  Double ported (60-120 mL capacity), best source.
   3.2.4 Rotating Table.  Uniform exposure of samples within the oven.
   3.2.5 Volumetric Glassware.  50-100 mL capacity (Class A borosilicate).
   3.2.6 Bottles, Linear Polyethylene or Polypropylene with Leakproof Caps, for Storing Samples.
Teflon® bottles for storing multielement standards (500 mL,  125 mL, and 30 mL),  best source.
Page 3.1-2             Compendium of Methods for Inorganic Air Pollutants             June 1999

-------
Chapter IO-3                                                                   Method IO-3.1
Chemical Analysis                                                               Filter Material

   3.2.7 Centrifuge Tubes. Oak Ridge polysulfone tubes with screw caps of polypropylene, 30 mL.
   3.2.8 Nylon or Teflon® 0.45 um Syringe Filters.  Acrodisc® No. 4438 or equivalent and syringes for
rapid nonmetals contributing filtering.
   3.2.9 Sterile Polypropylene Tubes with Screw Caps of Polypropylene, 15 mL Capacity. Best source.
   3.2.10 Pipette. Automatic dispensing with an accuracy of setting 0.1 mL or better and repeatability of
20 ,uL, Grumman Automatic Dispensing Pipette, Model ADP-30DT or equivalent.
   3.2.11 Particle Mask. 3M, No. 8500, to be worn while cutting and handling glass-fiber filters.
   3.2.12 Template.Aid in sectioning the glass fiber filter.  Federal Register 43 (194): 46258-46261.
   3.2.13 Pizza Cutter, Thin Wheel.   Clean razor blade (< 1 mm).
   3.2.14 Vortex Mixer.  VWR2 variable speed or equivalent.
   3.2.15  Hydrochloric Acid.   Baker Instra-Analyzed, concentrated (sp.gr. 1.19)  or  equivalent, for
preparing samples.
   3.2.16 Nitric Acid.  Baker Instra-Analyzed, concentrated (sp.gr. 1.41) or equivalent, for preparing
samples.
   3.2.17 ASTM Type I Water.  ASTM D193.
   3.2.18 Extraction Solution (5.55% HNO3/16.75% HC1).  Prepare  by adding in ~ 500 mL of Type I
DI water, 55.5 mL of concentrated HN03, and 167.5 mL of concentrated HC1, dilute to one liter with Type I
DI water.

3.3 Hot Acid Extraction Apparatus and Materials

   3.3.1 Thermolyne Model 2200 Hot-Plate or Equivalent.

[Note:  Temperature of the extracts may be monitored by the use of a beaker containing a thermometer and
similar reagents as the samples.]

   3.3.2 Volumetric Glassware.  50-100 mL capacity (Class A borosilicate).
   3.3.3 Bottles, Linear Polyethylene or Polypropylene with Leakproof Caps, for Storing Samples.
Teflon® bottles for storing multielement standards (500 mL, 125 mL, and 30 mL).
   3.3.4  Centrifuge Tubes.   Polypropylene or Oak Ridge polysulfone tubes with screw caps of
polypropylene, 30 mL (Nalgene 3119-0050/3115-0030 or equivalent).
   3.3.5 Nylon or Teflon® 0.45 um Syringe Filters.  Acrodisc® No. 4438 or equivalent and syringes for
rapid nonmetals contributing filtering.
   3.3.6 Sterile Polypropylene Tubes with Screw Caps of Polypropylene, 15 mL capacity.  Falcon
Model No. 2099 or equivalent.
   3.3.7 Pipette. Automatic dispensing with an accuracy of setting 0.1 mL or better and repeatability of
20 /jL.  (Grumman Automatic Dispensing Pipette, Model ADP-30DT or equivalent).
   3.3.8 Particle Mask.  3M, No. 8500.  To be worn while cutting and handling glass-fiber filters.
   3.3.9 Vortex Mixer.  VWR2 variable speed or equivalent.
   3.3.10 Hydrochloric Acid.  Baker Instra-Analyzed, concentrated (36.5%-38%/12.3 M) or equivalent,
for preparing samples.
   3.3.11   Nitric Acid.  Baker Instra-Analyzed, concentrated (70% 16M) or equivalent, for preparing
samples.
   3.3.12 ASTM Type I Water.  ASTM D193.
June 1999              Compendium of Methods for Inorganic Air Pollutants             Page 3.1-3

-------
Method IO-3.1                                                                       Chapter IO-3
Filter Material	Chemical Analysis
4. Filter Medium Selection

4.1 Introduction

   4.1.1  In general, the filter medium depends on the purpose of the test.  For any given standard test
method, the appropriate medium will be specified.  However, it is important to be aware of certain filter
characteristics that can affect selection and use.
   4.1.2  Selecting  a  filtration substrate for time-integrated SPM monitoring must be made with  some
knowledge of the expected characteristics and a pre-determined analytical protocol. For any given standard
test method, the appropriate medium will normally be specified.
   4.1.3 In high-volume sampling, four types of filter material to capture SPM are commonly used.  They
include cellulose fiber,  quartz/glass fiber, mixed fiber, and membrane filter types.  Selecting a filter depends
upon variables such as background metal content, artifact formation, and affinity for moisture. The basic
characteristics of the types of filter material used in high volume are outlined in Table  1 sampling.  Useful
filter properties are described  in Table 2.  Several characteristics  are important in  the selection of filter
media. They are:
   • Particle Sampling Efficiency.  Filters should remove more than 99% of SPM drawn through them,
     regardless of particle size or flow rates.
   • Mechanical Stability. Filters should  be strong enough to minimize leaks  during sampling and
     wear during handling.
   • Chemical Stability.  Filters should not chemically react with the trapped SPM.
   • Temperature Stability.  Filters should retain their porosity and structure during sampling.
   • Blank Correction. Filters should not  contain high concentrations of target compound analytes.
Quartz fiber filter medium is most widely used for determining mass loading. Weight stability with respect
to moisture is an attractive feature.  Quartz fiber filters provide high efficiency and collect airborne particles
of practically every size and description.  Typical characteristics of quartz fiber filters are (1) a fiber content
of high purity quartz, (2) a binder of below 5% (zero for binderless types), (3) a thickness of approximately
0.5 mm, (4) a surface with no pinholes, and  (5)  an allowance of no more than 0.05% of smoke particles to
pass through the filter at a pressure of 100mm of water with a  flow rate of 8.53 m/min (28 ft/min), as
determined by ASTM-D2986, Method for Evaluation of Air Assay Media by the Monodisperse DOP (Dioctyl
Phthalate) Smoke Test.

Particulate matter collected on quartz fiber filters can be analyzed for many constituents.  If chemical analysis
is anticipated, binderless  filters should be  used.  Glass is a commercial product generally containing
test-contaminating materials; therefore, appropriate background corrections should be made. Background
concentration of various metals associated with different grades  of quartz fiber filters are documented in
Table 3.
   4.1.4 Silica fiber filters are used when it may be required or desirable to use a mineral fiber filter,  which
may later be extracted by strong reagents.  These fibers are usually made by leaching glass fibers with strong
mineral acids followed  by washing with deionized water. The fibers are rather weak but can be formed into
filter sheets using little or no binder. These filters have been recently  developed and are  commercially
available.
   4.1.5 For some purposes, airborne particles may be collected on cellulose fiber filters. Cellulose low-ash
filters are especially useful  when the filter is to be destroyed by ignition or chemical digestion.  However,
these filters have higher flow resistance (lower sampling rate) and have been reported to have much poorer
Page 3.1-4              Compendium of Methods for Inorganic Air Pollutants             June 1999

-------
Chapter IO-3                                                                      Method IO-3.1
Chemical Analysis                                                                 Filter Material

collection efficiency than the glass fiber  media.   Furthermore, cellulose is very sensitive to moisture
conditions, and even with very careful conditioning before and after sampling, accurately weighing the
collected particles is difficult.  The filter should be enclosed in a lightweight metal can with a tight lid and
weighed.
   4.1.6 As documented in the 40 CFR Part 58, Appendices A and B, identify the filter specifications when
used as part of the Federal Reference Method for Particulate Matter in Ambient Air.  These specifications
include (1) a quartz-fiber, nonhydroscopic filter, (2) a size of approximately 8" x 10", (3) an exposure area
of approximately 63 in.2, (4) a 99% collection efficiency as measured by ASTM-2986 (DOPtest) for particles
0.3p.m diameter, (5) a pressure drop range of 42-54 mm Hg at a flow rate of 1.5 m 3/min through the nominal
exposed area,  (6) a pH of 6 to 10, and (7) a maximum weight integrity of 2.4 mg.

4.2 Visual Filter Inspection

   4.2.1  After purchased, all filters must be visually inspected for defects, and defective filters must be
rejected if any are found.  Batches of filters containing numerous defects  should be returned to the supplier.
   4.2.2  The following are specific defects to look for:
     4.2.2.1 Pinhole. A small hole appearing as a distinct and obvious bright point of light when examined
over a  light table or screen, or as a dark spot when viewed over a black  surface.
     4.2.2.2 Loose material. Any extra loose material or dirt particles on the filter that must be brushed
off before the filter is weighed.
     4.2.2.3 Discoloration. Any obvious visible discoloration that might be evidence of a contaminant.
     4.2.2.4 Filter nonuniformity. Any obvious visible nonuniformity in the appearance of the filter when
viewed over a light table or  black surface that might  indicate gradations in porosity across the face of the
filter.
     4.2.2.5 Other. A filter with any imperfection not described above, such as irregular surfaces or other
results of poor workmanship.
   4.2.3  Visually inspect each filter in front of an area light and  observe for any specific defects listed
above.
   4.2.4 Use a renumbering stamp to code the filter on its noncollection  side with a 7-digit code before tare
weighing.  The noncollection side of the filter is designated by the manufacturer printed number and by a
mesh texture.  The number code might be as follows:

   Example: Filter Number Code = 9622001

     First 2 digits  = yr,  such as 96 for 1996
       Third digit  = project, such as 2
     Fourth digit  = filter type, such as 2 for 8" x 10" quartz fiber, Whatman QMA type
     Last 3 digits  = filter number, such as 001

5. Gravimetric Determination

5.1 Introduction
   5.1.1 The filter is weighed (after moisture equilibration) before and after use to determine the net weight
(mass)  gain.  The total volume of air sampled corrected to EPA standard conditions (25 °C, 760 mm Hg) is
determined from the measured flow rate and the sampling time.  The concentration of TSP matter in the
ambient air is computed as the mass of collected particles divided by the volume of air sampled (corrected
to standard conditions) and expressed in p.g/std m3 (see Inorganic Compendium Method 10-2.4). For samples
collected at temperatures and pressures  significantly different than standard conditions, the corrected
June 1999              Compendium of Methods for Inorganic Air Pollutants              Page 3.1-5

-------
Method IO-3.1                                                                      Chapter IO-3
Filter Material                                                                 Chemical Analysis

concentrations may differ substantially from actual concentrations,ug/m3, particularly at high elevations. The
actual particulate matter concentration can be calculated from the corrected concentration using the actual
temperature and pressure during the sampling period.
   5.1.2 Verify that the weighing room conditions are within the limits. Filter equilibrium and weighing
should be performed under controlled atmospheric conditions-a temperature of 25 ± 10°C and a relative
humidity < 50% (normally 50±5%  humidity).
   5.1.3 Use the results from  the motorized psychrometer to verify the temperature and relative humidity
indicated by the hygrothermograph.  Record the psychrometer values on the strip chart, along with the date,
time, and your initials.

[Note:  For traceability purposes, document your initials and full name in the front of the weighing room
notebook.]

   5.1.4  Record the room equilibration data on the Weighing  Room Atmospheric Condition Form (see
Table 4).

5.2 High Volume Filter Weighing Procedure

   5.2.1 Filter Handling Procedure.
     5.2.1.1 Filters should only be handled with finger cots or vinyl (nonpowdered) gloves. This procedure
applies to filter handling in the field  as well as in the weigh room.
     5.2.1.2 Avoid  using metal tweezers since the filters later will be used for metals  analysis.  When
handling filter with gloved fingers or with any type of tweezers,  avoid touching  the sampled area.
   5.2.2 Initial Weighing of  High Volume Filter.
     5.2.2.1 Upon receipt of new high volume filters (8" x  10" quartz fiber), take them to the climate
controlled room, remove the paper and plastic envelope (wearing clean plastic gloves), place each on edge
in a clean metal file rack, and cover  with  clean white paper towels.
     5.2.2.2 Allow the filters  to equilibrate in the metal file rack in the weighing room atmosphere for at
least 24 h. Humidity and temperature must be within Federal Reference method specification, (i.e., < 50%
and 15-35°C, respectively).
     5.2.2.3 Zero the high volume  balance before weighing.
     5.2.2.4 Manually calibrate the balance. However, checks against two working NIST traceable weights
(Class S) standards should be conducted before the daily weighing. If the difference between the traceable
weights is more than  0.5 mg, do not use the balance until it has been repaired.
     5.2.2.5 Record the results on the  Weighing Balance  Check Form (see Table 5).
     5.2.2.6 Weigh each filter and record filter numbers and tare weights on the Filter Weighing Form (see
Table 6).
     5.2.2.7 Return the weighed filters to the plastic and  paper  envelopes.
     5.2.2.8 Weigh  filters in lots of approximately  100, if possible.  After every tenth weighing, recheck
the zero of the balance.  The balance response should be ± 1 mg from 0. All differences should be corrected.
Any difference exceeding  1 mg requires reweighing the previous ten filters.  Any filter weight outside the
normal range of 3.5-5.0 g requires immediate investigation. In addition, after every tenth filter weighing,
the analyst should review at least one of the working standards.  Once again, if this measurement disagrees
from the verified value by more than 0.5 mg, reweigh the standard. If the two measurements still disagree,
troubleshoot and take appropriate corrective action,  which may  include (1) reweighing some or all of the
previously weighed filters, (2) recertifying the working standards against the laboratory primary standards,
and/or (3) having a service technician repair the balance.  At the end of the weighing session, reweigh both
Page 3.1-6              Compendium of Methods for Inorganic Air Pollutants              June 1999

-------
Chapter IO-3                                                                      Method IO-3.1
Chemical Analysis                                                                 Filter Material

working standards.  Record the measurements on the Weighing Balance Check Form.  If both do not agree
within 0.5 mg, then all weighings from the previous acceptable check must be repeated.
      5.2.2.9 A second analyst should reweigh 10% of the filters.  If the difference between the weights is
less than 1.0 mg,  the results are acceptable.
      5.2.2.10 If  the difference is greater than this limit, wait another 24 h and reweigh them.
      5.2.2.11 If  the results are still outside acceptable limits, wait another 24 h and reweigh them again.
Then report the last reweigh values as the pre-field tare weights.
   5.2.3  Final Weighing of High Volume Filter.
      5.2.3.1 Exposed filters should be logged into the laboratory computer and received in individual manila
folders, with computer printed identification labels affixed.  No exposed filter should be touched until this
label is affixed.
      5.2.3.2 Condition all filters in the manner specified by the Federal Reference Method,  as documented
in Sections 5.1.2  and 5.2.2.
      5.2.3.3 Weigh all filters according to the Tare Weighing Procedure  in Section 5.2.2. Record final
weights on the Filter Weighing Form (see Table 6).
      5.2.3.4 For  filters not to be analyzed, put an asterisk in the space preceding the four-letter code. Leave
this space blank for samples to be analyzed. Sign and  date the forms.
      5.2.3.5 Archive asterisked high volume filters.
      5.2.3.6 Have a second analyst reweigh 10% of the filters and verify that the weights have not changed.
      •  If the difference between the weights is less than  2.0 mg, the results are acceptable.  Use the results
        from the first weighing.
      •  If the difference is greater than this limit, reweigh 100% of that lot and use the last reweigh weight.
     5.2.3.7 Calculate and report the particulate matter concentrations as:

Where:                                       (Wf  -  W.) x 10"
                                     SPM = —	
                                                   vstd


     SPM   = mass concentration of suspended particulate matter (TSP or PM10), p.g/std m3.
       Wj   = initial weight of clean filter, g.
       Wf   = final weight of exposed filter, g.
       Vstd   = air volume sampled,  converted to standard conditions (25 °C and 760 mm Hg), std m3.
       106   = conversion of g to p.g.

5.3 Dichotomous and Partisol® Filter Weighing Procedure

   5.3.1 Initial Weighing of Dichotomous or Partisol® Filters.
      5.3.1.1   Fabric filters, 37-mm or 47  mm (as appropriate for the samples) in diameter,  with a
circumferential plastic reinforcing ring are usually supplied in small boxes. Open the boxes in the climate-
controlled room under conditions suitable for high volume weighing.  Cover with a clean paper towel and
allow to equilibrate  for 24 h.
      5.3.1.2  Weigh filters on a Mettler microbalance; each balance is identified by a balance number.
June 1999              Compendium of Methods for Inorganic Air Pollutants              Page 3.1-7

-------
Method IO-3.1                                                                      Chapter IO-3
Filter Material                                                                 Chemical Analysis

      5.3.1.3  Assign each balance a block of 7-digit sample numbers to be used sequentially.  Assign a
sample number to each filter when it is tared.

[Note:  Inaccuracies in this aspect of the procedure will cause irremedial sample loss.]

      5.3.1.4 Turn on the microbalance and allow it to warmup for at least 15 min.  If the balance is used
daily, leave it on at all times.
      5.3.1.5  Manually calibrate the microbalance with two working NIST traceable weight  (Class S)
standards (for example, a 100-mg standard and a 200-mg standard).  If the difference between the traceable
weights is more than 3 p.g,  reweigh the working standards.  Record the Results on the Weighing Balance
Check Form (see Table 7).
      5.3.1.6 If the values still disagree, troubleshoot and take appropriate corrective action, which may
include (1) recertifying the working standards against the laboratory primary standards, and/or (2) having
a service technician repair the microbalance.
      5.3.1.7 Using clean nonserrated tweezers that will not damage the filter, remove the filter from the
Lexan jig or filter cassette and place it on the weighing pan. Turn the release lever to " 1" and dial in tare
weights until a reading between 0.000 and  7.000  is  obtained.  Allow the  reading to stabilize (which may
require 2 to 4 min). Record the reading and the dialed-in tare weight on the Filter Weighing Form (see Table
8). Return the release lever to "0" and remove the  filter from the weighing pan.

[Note:  Do not use metal tweezers.]

      5.3.1.8 Place a white label on a clean 50-mm diameter plastic petri dish (tight fitting lid type).
      5.3.1.9 Assign a sample number to each filter (from those assigned to that balance), taking extreme
care to avoid duplication or missed numbers.
      5.3.1.10 Record the assigned sample  number on the petri dish label, leaving sufficient room for one
more letter to be written following the number. Do not record the balance number on this  label.
      5.3.1.11 Record the balance number, the assigned sample number, the dialed-in tare weight, and the
digital-displayed tare weight on the sample form. Number each sheet of the form sequentially in  the upper
right-hand corner. Write "Tare Weight, Dichot or Partisol® Filters" on the top of each sheet.  When bound,
these forms may serve as the laboratory notebook.
      5.3.1.12 Place the weighed filter in its numbered petri dish for future use.
      5.3.1.13 After every tenth filter weighing, the analyst should check the "zero" and reweigh at least
one of the working standard. Record the measurement on the Weighing  Balance Check Form. Once again,
if this measurement disagrees from the verified value by more than 3 p.g, reweigh the standard.  If the two
measurements still disagree, troubleshoot and take appropriate corrective action, which may include (1)
reweighing some or all of the previously weighed filters, (2) recertifying the working standards against the
laboratory primary standards, and/or (3) having  a service technician repair the balance.  At the end of the
weighing session, reweigh  both working  standards.  Record the measurements on the Weighing Balance
Check Form. If both do not agree within 3 p.g then all weighings from the previous acceptable check must
be repeated.
      5.3.1.14  At the  end  of the weighing session,  at least 10% of the filters should be reweighed by a
second analyst.  Record the replicate measurement  on the Filter Weighing Form (see Table 6).  If the
replicate measurement disagrees from the original  measurement by more than 15 p.g, reweigh the filter. If
the measurements still disagree, troubleshoot and take appropriate corrective action, which may include (1)
reweighing all or some of the previously weighed  filters, (2) reweighing the working standards, or (3) having
a service technician repair the microbalance. The  analyst should not attempt to repair the  microbalance.
Page 3.1-8              Compendium of Methods for Inorganic Air Pollutants             June 1999

-------
Chapter IO-3                                                                       Method IO-3.1
Chemical Analysis                                                                  Filter Material

      5.3.1.15 Return the filter to the filter-handling container, replace the lid, and return it to conditioning
chamber to protect it from contamination prior to sampling.
   5.3.2 Final Weighing of Dichotomous or Partisol® Filter.
      5.3.2.1 Filters should be returned from the field with a computer printed label affixed to the petri dish.
The label should contain a five-character identification code that is different from the original sample number,
a balance ID, the balance tare, and other information.  All filters should be accompanied by extra labels.
Some will have the words "To Be Analyzed" on the labels.  The filter in each petri dish should rest in a Lexan
jig or filter cassette.
      5.3.2.2 Weigh each filter on  the balance on which its tare  weight was obtained.  In the climate-
controlled room,  group the filters according to recorded balance numbers. Open the petri dishes, making
certain that lids are placed under the bottoms and that no mixup occurs. Cover with a clean white paper towel
and allow to  equilibrate.
      5.3.2.3 Repeat Section 5.3.1.4 to 5.3.1.6 of the  filter tare weighing procedure.
      5.3.2.4 Using clean, nonserrated tweezers that will not damage the filter, remove the filter from the
Lexan jig or filter cassette and place  it  on the  weighing pan.  Dial in the  tare weight recorded on the
information label and turn the release lever to" 1." Allow  the reading to stabilize (which may require 2 to 4
min). Record the reading and the dialed-in tare weight.  Return the release lever to " 0" and remove the filter
from the weighing pan.

      5.3.2.5 After every tenth filter weighing, the analyst should check the "zero" and reweigh at least one
of the working standards.  Record the measurement on the Weighing Balance Check Form. Once again, if
this measurement disagrees from the verified value by more than  3 ug, review the standard.  If the two
measurements still disagree,  troubleshoot and take appropriate corrective action, which may include  (1)
reweighing some or all of the previously weighed filters,  (2)  recertifying the working standards against the
laboratory primary standards, and/or (3)  having a service technician repair the balance.  At the end of the
weighing session, reweigh both working standards.  Record the measurements on  the Weighing Balance
Check Form.  If both do not agree within  3 p.g, then all weighings from the previous acceptable check must
be repeated.
      5.3.2.6 At the end of the post weighing session, at  least 10% of the filters should be reweighed by a
second analyst.   Record the  replicate  measurement on the Filter Weighing Form  (see Table 8).   If the
replicate measurement disagrees from the post measurement  by more than 15 p.g,  reweigh the filter. If the
measurements  still  disagree, troubleshoot and  take appropriate  corrective action, which  may include
(1) reweighing all or some of the previously weighed filters,  (2) reweighing the working standards, and/or
(3) having a  service technician repair the microbalance.  The analyst should not attempt  to  repair the
microbalance.
      5.3.2.7 If the dichotomous filter is not to be analyzed, use the tweezers to place  it in  a small glass
envelope to which one  of the extra labels has been affixed. Place an asterisk before the five-character code
on the form.  Deliver these filters to the filter bank for archiving.
      5.3.2.8 If the filter is to be analyzed, use tweezers to carefully put it back into the petri dish.  Place
the petri dish carefully in a box.
      5.3.2.9 Place a label on a sheet of 8 Vz"  x  11" paper for NAA, XRF, or other analysis as appropriate.
Indicate the  page number and balance number on each  list.  Keep the samples in the box in an order
corresponding with the lists.
      5.3.2.10 Without jostling the box, deliver it, the two lists, and the original Field Test Data Sheets with
two copies of each to the sample custodian who  will initial the original forms and return them upon receipt.
      5.3.2.11  Calculate and report  the particulate matter concentration for both fine and coarse samples
utilizing the following  equation:
June 1999              Compendium of Methods for Inorganic Air Pollutants             Page 3.1-9

-------
Method IO-3.1                                                                      Chapter IO-3
Filter Material                                                                 Chemical Analysis


                                     PM _  (Wf  -  W.) x 106
                                                  vstd

where:
        PM  = mass concentration of particulate matter (TSP, fine or coarse friction), p.g/std m3.
         Wj  = average initial weight of clean filter, g.
         Wf  = average final weight  of exposed filter,  g.
        Vstd  = air volume sampled,  converted to standard conditions, std m3 (see Inorganic Compendium
Method 10-2.4).
         106  = conversion of g to p.g.


5.4 Transport of Filters

   5.4.1   After collecting samples,  transport the  filters  to the  laboratory,  taking care  to minimize
contamination and loss of the sample.  Glass fiber filters should be transported or shipped in a shipping
envelope. Cover the exposed surface of the membrane filters with an unexposed filter and seal the filter in
plastic filter holders.
   5.4.2  Assign numbers to the filters and log them into the data record form, ensuring that any necessary
sampling information is included (Untreated filter samples may be stored indefinitely.)
   5.4.3  Provide one blank sample with every 10 actual samples.  No air is drawn through the blank filter,
but it is subjected to the same  handling and shipping manipulations as the actual samples.
6. Extraction of Glass Fiber Filters in Preparation for Metal Analysis
6.1 Introduction

This section describes both a microwave-extraction procedure and a hot-acid extraction procedure to extract
inorganics from the particulate quartz glass-fiber filter.  Following extraction, target analytes are analyzed
by ICP, ICP/MS, FAA, or GFAA.
   6.1.1 Ambient air quartz fiber filters should be received folded in half lengthwise with the particulate
material inward  and enclosed  in protective envelopes.  Store these protective envelopes approximately
15°-30°C until analysis.
   6.1.2 The maximum sample holding times is usually 180 days. Analyze the samples within  180 days,
even if these times are less than the maximum data submission times allowed.

6.2 Microwave Extraction Procedure

   6.2.1 Filter Cutting Procedure.
      6.2.1.1 Cut a 1" x 8" strip from the 8" x 10" filter using a template (see Figure 1) and cutting tool (see
Figure 2) as described in the Federal Reference Method for lead.  Use a laboratory microwave extraction
system to extract the metals with a hydrochloric/nitric acid solution. After cooling, mix the digestate and use
Page 3.1-10             Compendium of Methods for Inorganic Air Pollutants             June 1999

-------
Chapter IO-3                                                                      Method IO-3.1
Chemical Analysis                                                                 Filter Material

Acrodisc® syringe filters to remove any insoluble material. Microwave extraction is used to prepare samples
for ICP,  ICP/MS, FAA, or GFAA.
      6.2.1.2 Prior to use, acid wash the plexiglass filter template, the polysulfone centrifuge tubes and caps,
and  all other laboratory  equipment  that will come into contact with the  filter samples  to prevent
contamination.
      6.2.1.3 Using vinyl gloves, place the acid-cleaned filter template and cover inside a balance hood for
cutting quartz fiber filters.
      6.2.1.4 Wipe plexiglass template base, cover, and cutting blade with a clean, dry Kimwipe® to prevent
sample cross-contamination.
      6.2.1.5 Unfold the 8" x 10" quartz filter to be sectioned and carefully place sampled side up (numbered
side  down) within the plexiglass template filter margins.
      6.2.1.6 Carefully (without disturbing sampled area of filter) place the grooved cover, notch side down,
within the margins of the base template.  Use a clear cutting blade to cut a 1" x  8" strip.
      6.2.1.7  Using gloved fingers, accordion-fold or tightly roll the filter strip and transfer on edge to an
acid  cleaned polysulfone® tube, labeled with  wax pencil.  DO NOT use barcodes or tape in microwave.
      6.2.1.8 Clean filter template between samples with dry Kimwipes®.  (Gloves should be changed after
50 filters to minimize cross-contamination.)
      6.2.1.9 Duplicate sample frequency is normally 1 per 20 field samples (see  Table 9). Prepare a sample
filter duplicate  by moving the template cover to a second portion of the field collected filter.  Cut an
additional  filter strip by moving the  template  cover to a  second section  of  the  filter and  repeat
Sections  6.2.1.6 through 6.2.1.8 above using a separate polysulfone tube.
      6.2.1.10  Select a field collected filter for matrix spiking.  In addition to the filter strip cut for
determining metals, section a second portion of the filter, and fortify (spike) with  target metals.
      6.2.1.11  Prepare matrix spike samples at a frequency of 1 per 20 field samples or a minimum of 1 per
extraction day (see Table 9). Move the template to a second section of the filter and repeat Sections 6.2.1.6
through 6.2.1.8, using a separate polysulfone tube and spike as shown in Table  9.
   6.2.2 Microwave Calibration Procedure. Calibration of the microwave unit is a critical step prior to
its use. In order that absolute power settings  may be interchanged from one microwave unit to another, the
actual delivered power must be determined, which allows the analyst to relate power in Watts to the partial
power setting of the unit (% Power).
   Calibration of a laboratory microwave unit (see Figure 3) depends on the type of electronic system used
by the manufacturer. If the unit has a precise and accurate linear relationship between the output power and
the scale  used in controlling the microwave unit, the calibration can be a three-point calibration in the range
of 50% to  100% power.   If the unit does not prove linear (±10 W) using the three-point technique, a
multiple-point calibration is necessary. A bracketed calibration range of the digesting power to be used is
recommended for determining the calibration points. If the unit power calibration needs  multiple-point
calibration, the point where the linearity begins must  be identified.  For example,  a calibration  at 100,  99,
98, 97, 95, 90, 80, 70, 60,  and 50% power settings can be applied and the data plotted.  The nonlinear
portion of the calibration curve can be excluded or restricted. Each percent is equivalent to approximately
5.5-6.5 W and becomes the smallest unit of power that can be controlled.  If 20-40 W are contained from
99-100%, that portion of the microwave calibration is  not controllable by 3-7 times that of the linear portion
of the control scale and will prevent duplication of precise power conditions specified in that portion of the
power scale.
   6.2.3 Microwave Power Evaluation. The equation in the following section evaluates the power available
for heating in a microwave  cavity.  The variables  are determined by  measuring the temperature  rise in
1 kilogram of water exposed to electromagnetic radiation for a fixed period of time. The following procedure
is used for evaluating each calibration point,  represented as % power output for each microwave.
June 1999              Compendium of Methods for Inorganic Air Pollutants            Page 3.1-11

-------
Method IO-3.1                                                                     Chapter IO-3
Filter Material                                                                Chemical Analysis

      6.2.3.1 Measure and record a 1 kilogram (1,000 g ±0.1 g) sample of room temperature (23°±2°C)
distilled water in a thick-walled microwave transparent (Teflon®) beaker for each calibration point.
      6.2.3.2 Measure and record the initial temperature of the water, (T(), to within 0.1 °C.  The starting
temperature should be between 22 and 26°C.
      6.2.3.3 Place the Teflon®  beaker in microwave and irradiate at full power (100% point) for 2 min
(120s). Each calibration point (i.e., 100%, 50% or multi-points) requires a separate clean beaker containing
water at room temperature.
      6.2.3.4 Remove beaker from the microwave and measure and record the maximum final temperature
(Tf) to 0.1 °C, within 30 s of the end of irradiation. This process should be done while stirring continuously
(an electronic stirrer using a large stir bar works best).

Calculate the microwave power according to the following formula:

                                            K x C  x M x AT
                                  Power =
                                                  p
                                      K x  C  x M
                                      	E	 = 34.87
                                      Power = 34.87 x AT

where:
  Power =  The apparent power absorbed by the sample, watts (W = joule-s"2).
      K =  The conversion factor for thermochemical calories-s"1 to W = 4.184.
      Cp =  The heat capacity, thermal capacity, or specific heat  (cal-g"1-0^1 =1.0 for water).
      M =  The mass of the sample, grams.
     AT =  Tf-Tj, °C.
        t =  Time, s.

     6.2.3.5 Derive an equation for the linear portion of the calibration range and determine the equivalent
value in watts of the arbitrary setting scale.  Use the actual power in watts to determine the appropriate setting
of the particular microwave unit being used. Each microwave unit will have its own (% power) setting that
corresponds to the actual power (in wattage) delivered to the samples.
     6.2.3.6 An initial multipoint power evaluation should be performed for each microwave unit. If linear,
the calibration should be checked on a regular  basis, using the 3-point calibration verification routine. A
single point verification may be appropriate when utilizing a single power output for digestion.  If any part
of the power source to the microwave has been serviced or altered, the entire calibration must be reevaluated.

   6.2.4 Cleaning Procedure for PFA Vessels. All digestion vessels must be acid cleaned and rinsed with
reagent  water prior to  use to prevent contamination.
     6.2.4.1 Wash each PFA vessel with deionized detergent and rinse with reagent water.
     6.2.4.2 Add 10 mL concentrated HN03 to each of 12 vessels, cap, and place in microwave.
     6.2.4.3 Heat vessels at 100% power in microwave  for 10 min as recommended by CEM (microwave
manufacturer).  Rinse  the vessels with copious amounts of deionized,  distilled water prior to use for any
Page 3.1-12            Compendium of Methods for Inorganic Air Pollutants             June 1999

-------
Chapter IO-3                                                                      Method IO-3.1
Chemical Analysis                                                                 Filter Material

analyses.   If only  6  vessels are to be  cleaned, 70%  power  may  be utilized, which corresponds  to
approximately 5% per vessel.
    6.2.5  Digestion Procedure for Microwave Extraction For Ambient Filter Samples.

[Note: Nitric and hydrochloric acid fumes are toxic. Prepare in a well-ventilated fume hood. Mixing results
in an exothermic reaction. Stir slowly.]

      6.2.5.1 Using vinyl gloves or plastic forceps, retrieve the filter strip from Section 6.2.1 and place on
its edge in a labeled centrifuge tube.  Using the plastic forceps,  crush the filter strip down into the lower
portion of the centrifuge tube to ensure acid volume will  cover entire filter.

[Note: A breathing mask and vinyl gloves are required for safety of personnel handling dry glass-fiber filters.
The breathing mask prevents the inhalation of minute glass shards and particulate  material.  The gloves
protect the skin from the same materials and also prevent contamination of the sample by skin secretions.  A
recommended alternate to the use of a breathing mask would be performing cutting and transfer operations
involving sample filters in a laminar flow hood, if available.]

[Note: More than one strip from a filter should be extracted to ensure adequate sample volume for sample
and QC sample analysis. Blank filter samples should be extracted and analyzed, and digestion blanks should
be run to ensure low levels of metals in the reagents used.]

      6.2.5.2 Using a preset calibrated automatic dispensing pipette or Class A glass pipette,  add 10.0 mL
of the extraction solution to each of the centrifuge tubes.  The acid should cover the strip completely.  The
sequence of adding the filter strip and acid to the centrifuge tube may  be reversed, if more convenient,
without affecting the  results.  Place  the  centrifuge  tube in a Teflon® PFA vessel  containing 31 mL  of
deionized water. Continue this process for a total of 12 samples to maximize microwave capacity.
      6.2.5.3 Place the PFA vessel caps with the pressure release valves on the vessels hand-tight and tighten
using the capping station to a constant torque of 12 ft-lb.  Weigh and record the  capped vessel assembly  to
the nearest 0.01 g.  Place the vessels in the microwave carousel. Connect each sample vessel to the overflow
vessel using the Teflon® PFA connecting tubes (see Figure 3).
      6.2.5.4 Place the carousel containing the 12 vessels onto  the turntable of the microwave unit.  Any
vessels containing 10  mL of acid solution for analytical blank  purposes  are counted as sample vessels.
Irradiate the sample vessels at 486 W (power output) for 23 min.  (Based on the calibration of the microwave
as previously described).  If fewer than 12 samples are  to be digested, adjust  the microwave system by
reducing the power so that equivalent digesting power is delivered to the  smaller sample batch.  Generally,
each vessel represents approximately 5%  power.  Therefore, a reduction in W would be reduced by 30% if
only 6 vessels are digested.  This reduction is only approximate, and each microwave unit will produce a
different level of power output.
      6.2.5.5 At the end of the microwave program, allow the pressure to dissipate (venting may be utilized
with caution), then remove the carousel containing the vessels and cool in tap water for 10 min. Weigh the
capped vessels assembly to the nearest 0.01 g and compare to the initial weight to verify no loss of sample.
The initial and final weights should compare within 0.1 g.  If the initial and final weights do not agree within
0.01 g, the appropriate action must be taken which may  include rejecting  the digested sample.  Using the
capping station uncap  the microwave vessels,  remove the labeled centrifuge  tubes containing samples and
discard the water in the PFA vessels.
      6.2.5.6 Using a calibrated automatic dispensing pipette or a Class A glass pipette, add 10 mL  of
deionized distilled water to each centrifuge tube. Cap  the centrifuge tube  tightly  and  vortex (mix) the
contents thoroughly for 2-3 minutes to complete extraction. Using a nylon or teflon syringe pull-up a volume
June 1999              Compendium of Methods for Inorganic Air Pollutants            Page 3.1-13

-------
Method IO-3.1                                                                       Chapter IO-3
Filter Material                                                                  Chemical Analysis

of sample from the centrifuge tube, place Acrodisc filter on syringe and dispense into a prelabeled sterile
15 mL centrifuge tube. Continue until centrifuge tube contains 10 mL of filtered digestate.
     6.2.5.7 The final extraction volume is 20 mL based upon the above procedure. The final extraction
solution concentration is 3% HN03/8%  HC1.  The filtered sample is now ready for analysis.  Store for
subsequent analysis by one or more of the Inorganic Compendium methods.

6.3 Hot Acid Extraction  Procedure

   6.3.1  Introduction.   A hot extraction procedure to solubilize metals from the glass-fiber filter for
subsequent analysis by ICP, ICP/MS, FAA, or GFAA is described in this method. An acid extraction
solution is used to extract the metals from the quartz filter on a hot-plate.
   6.3.2  Summary of Method.
     6.3.2.1 Use the hot-acid extraction procedure as an alternate when microwave  technology is not
available.
     6.3.2.2 Cut a 1" x  8" strip from the 8" x 10" filter as described in Federal Reference Method for lead.
The inorganics are extracted from the filter strip by a HC1/HN03 acid solution using a hot acid extraction
procedure.  After cooling, pour the digestate rinses to  a volumetric flask and dilute to volume. Filter to
remove any insoluble material.
   6.3.3  Hot Acid Extraction Procedure.
     6.3.3.1 Using vinyl  gloves or plastic forceps, retrieve the strip from Section 6.2.1 and place it in a
labeled 150 mL Griffin beaker. Place the filter strip down into the lower portion of the beaker to ensure acid
volume will cover entire filter.

[Note:  More than one strip from a filter should be extracted to ensure adequate sample volume for sample
and QC sample analysis. Blank filter samples should be extracted and analyzed and digestion blanks should
be run to ensure low levels of metals in the reagents used.]

     6.3.3.2 Using a preset calibrated automatic dispensing pipette or Class A glass pipette, add 10 mL of
extracting acid (see Section 6.2.5.2) for analysis.

[Note:  The acid should cover the strip completely.]

     6.3.3.3 Place beaker on the hot-plate, contained in a fume hood, and reflux gently while covered with
a watch glass for 30 min.  Do not allow sample to dry.  Remove the beakers from the hot-plate and allow to
cool.

[Caution:  Nitric acid fumes are toxic.]

     6.3.3.4 Rinse the beaker walls and wash with D.I. water. Add approximately 10  mL reagent water
to the remaining filter material in the beaker  and allow to stand for at least 30 min. This critical step must
not be deleted; it allows the acid to  diffuse from the filter into the rinse.  Transfer the extraction fluid in the
beaker to a 20 mL volumetric flask or other graduated vessel. Rinse the beaker and any remaining solid
material with Type I water and add the rinses to the flask.  Some solids from the filter may be transferred
to the flask with the rinses; this  is acceptable. Dilute to the mark with Type I water and  shake.
     6.3.3.5 Using a nylon or Teflon® syringe, pull-up  a volume of sample from the centrifuge tube,  place
disc filter on syringe, and dispense into a prelabeled sterile 15 mL centrifuge tube. Continue until centrifuge
tube contains 10 mL of filtered digestate.
Page 3.1-14             Compendium of Methods for Inorganic Air Pollutants              June 1999

-------
Chapter IO-3                                                                   Method IO-3.1
Chemical Analysis                                                              Filter Material

     6.3.3.6 The final extraction volume is 20 mL based upon the above procedure.  The final extraction
solution concentration is 3 % HN03/8% HC1.  The filtered sample is now ready for analysis. Store for
subsequent analysis by one or more of the Inorganic Compendnium methods.
June 1999              Compendium of Methods for Inorganic Air Pollutants            Page 3.1-15

-------
Method IO-3.1                                                                   Chapter IO-3
Filter Material                                                              Chemical Analysis

                     TABLE 1.  CHARACTERISTICS OF FILTER MEDIUM
  Cellulose Fiber (Cellulose Pulp)
    Low ash
    Maximum temperature of 150°C
    High affinity for water
    Enhances artifact formation for S0=4 and N0~3
    Good for x-ray/neutron activation analysis
    Low metal content
  Quartz Fiber (Quartz spun with/without organic binder)
    Maximum temperature up to 540 °C
    High collection efficiency
    Non-hydroscopic
    Good for corrosive atmospheres
    Very fragile however
    Difficult to ash; good with extraction
  Synthetic Fiber (Teflon® and Nylon11
    Collection efficiency  > 99% for 0.01 |jm particles
    Low artifact formation
    Low impurities
    Excellent for X-ray analysis
    Excellent for determining total mass due to non-hydroscopic nature
    Nylon fiber good for HN03 collection	
  Membrane Fiber (Dry gel of cellulose esters)
    Fragile; requires support pad during sampling
    High pressure drop
    Low residue when ashed
Page 3.1-16            Compendium of Methods for Inorganic Air Pollutants             June 1999

-------
Chapter IO-3
Chemical Analysis
                                                 Method IO-3.1
                                                 Filter Material
      TABLE 2. SUMMARY OF USEFUL PHYSICAL PROPERTIES OF VARIOUS FILTER
                                    MEDIUMS
Filter and Filter Composition
Teflon® (Membrane)
(CF2)n(2 p.m Pore Size)
Cellulose (Whatman 41)
(C6H1005)n
Glass Fiber (Whatman GF/C)
"Quartz" Gelman Microquartz
Polycarbonate (Nuclepore)
C15H14 + C03 (0.3 [im Pore
Size)
Cellulose Acetate/Nitrate
Millipore (C9H1307)n (1.21 pm
Pore Size)
Density, mg/cmz
0.5
8.7
5.16
6.51
0.8
5.0
pH
Neutral
Neutral
(Reacts with HN03)
Basic pH - 9
pH-7
Neutral
Neutral
(Reacts with HN03)
Filter Efficiency %
99.95
58% at 0. 3pm
99.0
98.5
93.9
99.6
June 1999
Compendium of Methods for Inorganic Air Pollutants
Page 3.1-17

-------
CTQ
fD
00
00
I
8,

ri-

fe
TABLE 3. EXAMPLE OF TYPICAL BACKGROUND METAL CONCENTRATION (pg/FILTER) OF VARIOUS GRADES
                                 AND TYPES OF FILTERS
Metal
Al
Ag
As
B
Ba
Be
Bi
Ca
Cd
Co
Cr
Cu
Fe
Mg
K
MR
Mn
Mo
N
Na
Ni
Pb
S
Sb
Si
Ti
V
Sn
1
1

<0.02
1
< 1


185


0.3
1.2
5.0
< 0.005
4.0
7
0.1

28
160

0.4
17
<0.02
15


9 5
41
2

<0.02
<2
<1
-
-
13
-
-
0.3
0.1
6.0
-
1.5
1.8
<0.05
-
-
40
-
0.2
<5
<0.02
<2
-
-
n 6
42
2
-
<0.02
2
< 1
-
-
13
-
-
0.3
0.4
6.0
< 0.005
1.5
1.8
<0.05
-
12
37
-
0.2
<5
<0.02
<2
-
-
n 6
542
1
-
<0.02
2
<1


9


0.7
0.2
3.0
< 0.005
0.6
1.0
<0.05

260
8

0.1
<5
<0.02
<2


n 3
Filter 17ch

-
-




29



0.6
5.0

7
6



30

1






Grades GF/A
4,300
<1
<6
6,100
8,500
0.2
0.3
2,500
1
11
0.2
56.0
100
-
775
1,090
8.0
2.0
-
1,830
6.0
10
26
<4
-
0.1
0.1
5 5nn
EPM2K
170
< 1
<6
42
50
< 1
<4
540
< 1
< 1
4.5
1
15

573
238
< 1
<2

1,020

2.5

<4

< 1

15
934QH
2,950
-
-

<1
0.1
0.8
7,000
0.8
5.5
3.0
7
265

125
2,800
2
4

1,100
2.5
2.0


-
<30
10
34
QMA
4
<1
<6
42
10
<1
<4
85
0.2
1.1
1.6
3.4
23
-
-
-
0.5
<2
-
280
3.4
2.3
-
<4
-
<1
-
m
QMB
-
-
-
-
-
< 1
7
-
< 1
< 1
0.7
3.4
29
-
-
-
<1
< 1
-
-
2.2
8.3
-
-
-
<4
<4
13
J? 2.
is
                                                                                                    2.
c

fD
H^
CO
CO
CO
                                                                                           n
                                                                                           sr
                                                                                           fD
                                                                                           3.0
                                                                                           o gr
                                                                                             S
                                                                                           > ff
                                                                                             "
                                                                                             i—i
                                                                                             9
                                                                                           K" oo

-------
Chapter IO-3
Chemical Analysis
                                               Method IO-3.1
                                               Filter Material
        TABLE 4. EXAMPLE WEIGHING ROOM ATMOSPHERIC CONDITION FORM
Equilibrium Period
Begin
Date










Begin
Time










End
Date










End
Time










Temperature Limits = 15°Cto
35°C
Max-
Min










Avg










Limits
met?










Relative Humidity Limits =
<50%
Max-
Min










Avg










Limits
met?










Name










               TABLE 5. EXAMPLE WEIGHING BALANCE CHECK FORM
Date










Time










Balance
Type










Balance
ID










Class S
Weights
Serial No.
or ID










mg
Class S
weight










Balance
weight










Difference










Limit =
0.5 mg
Limits
met?










Name










June 1999
Compendium of Methods for Inorganic Air Pollutants
Page 3.1-19

-------
CTQ
a

00
TABLE 6. EXAMPLE FILTER WEIGHING FORM
I
8,

ri-


fe
Filter No.














Pre-fleld Initial
Weighing
Weight
(mg)














Name-
Date














10% Second Weighing by Second Analyst
(Limit = 1.0 mg)
Weight
(mg)














Diff.
(mg)














Limit
met?














Name-
Date














Post-field Final
Weighing
Weight
(mg)














Name-
Date














10% Second Weighing by Second Analyst (Limit
= 2.0 mg)
Weight
(mg)














Diff.
(mg)














Limit
met?














Name-
Date














J? 2.

o> S-


 '§.
                                                                                                                      2. w
                                                                                                                      o
                                                                                                                      sr
                                                                                                                      fD

                                                                                                                      3.0
                                                                                                                      o gr
c


fD

H^

CO

CO

CO
                                                                              > s
                                                                                ~>
                                                                                i— i

                                                                                9
                                                                              K" oo

-------
Chapter IO-3
Chemical Analysis
                                                 Method IO-3.1
                                                 Filter Material
                TABLE 7.  EXAMPLE WEIGHING BALANCE CHECK FORM
Date










Time










Balance
Type










Balance
ID










Class S
Weights
Serial No.
or ID










mg
Class S
weight










Balance
weight










Difference










Limit = 3
ug Limits
met?










Name










June 1999
Compendium of Methods for Inorganic Air Pollutants
Page 3.1-21

-------
CTQ

a

00
TABLE 8. EXAMPLE FILTER WEIGHING FORM
                                                                             J? £
I
8,

ri-



fe
Filter No.














Pre-fleld Initial
Weighing
Weight
(mg)














Name-
Date














10% Second Weighing by Second Analyst
(Limit = 15/^g)
Weight
(mg)














Diff.
(mg)














Limit
met?














Name-
Date














Post-field Final
Weighing
Weight
(mg)














Name-
Date














10% Second Weighing by Second Analyst (Limit
= 15 ^g)
Weight
(mg)














Diff.
(mg)














Limit
met?














Name-
Date














                                                                                                                      o
                                                                                                                      a.
                                                                                                                    2.
c


CD

H^

CO

CO

CO
                                                                             n
                                                                             sr
                                                                             fD

                                                                             3.0
                                                                             o gr

                                                                              ^

                                                                             > s

                                                                               ~>
                                                                               i—i

                                                                               9
                                                                             K" oo

-------
Chapter IO-3
Chemical Analysis
                                                       Method IO-3.1
                                                       Filter Material
                    TABLE 9. EXAMPLE QUALITY CONTROL SAMPLES
Type
Method Blank
Filter Lot Blank
Filter Duplicate
Matrix Spikeb
LCSC
Frequency
1 per 20 samples
1 per filter lot change
1 per 20 samples
1 per 20 samples
1 per extraction day
Contains
I"x8" filter
strip
No
Yes
Yes
Yes
Yes
Comments11
Containing reagents only, to evaluate
background contributions from
reagents.
Analyzed prior to use of new filter lot.
This is a second I"x8" filter strip cut
from a single field sample.
See individual methods.
See individual methods.
aThese multimetal stock standards can be acquired from Spex Industries, Inc., Inorganic Ventures Inc., or
equivalent.
bThe matrix spike (MS) is a I"x8". strip cut from a field sample filter and spiked at a target level.
The Lab Control Sample (LCS) is a blank filter spiked with the same concentration of metals as the matrix
spike.
June 1999
Compendium of Methods for Inorganic Air Pollutants
Page 3.1-23

-------
Method IO-3.1
Filter Material
                                                              Chapter IO-3
                                                          Chemical Analysis
             MANILA RLE FOLDEH-TO PREVENT
             FILTER FROM STICKING TO PLASTIC
                                                                              RIGID PLASTIC
                   WIDTH Oh   12.7cm
                 GROOVE 1 cm -£  //  Jf    QLASS FIBER FILTER
                                      FOLDED (LENGTHWISE) IN HALF "
                                                '
                           ALL GROOVES
                            7. mm DEEP
                              25 rrar (1") WIDE
                          Figure 1. Example of templates for cutting filters.
Page 3.1-24
Compendium of Methods for Inorganic Air Pollutants
June 1999

-------
Chapter IO-3
Chemical Analysis
                                                       Method IO-3.1
                                                       Filter Material
                          STRIPS FOR
                        OTHER ANALYSES
                                          3/4" X 8" STRIP FOR
                                           LEAD ANALYSIS
                         Figure 2. Diagram of filter cutting procedure.
June 1999
Compendium of Methods for Inorganic Air Pollutants
Page 3.1-25

-------
Method IO-3.1
Filter Material
                                             Chapter IO-3
                                         Chemical Analysis
         MICROWAVE EXTRACTION

                                     Pressure
                                   ^/monitor
                                        _MDS
                                         unit
                                        DIGESTION VESSEL
                                             ASSEMBLY
               Pressure monitoring
                 vesel assembly
                        Venting nut
                                       Relief valve
                                    Vent tubing
                                                        Vessel cap
                                                        Vessel body
                  Figure 3. Example of microwave digestion system.
Page 3.1-26
Compendium of Methods for Inorganic Air Pollutants
June 1999

-------