EMISSION FACTOR DOCUMENTATION FOR
              AP-42 SECTION 1.9,
         RESIDENTIAL FIREPLACES
                     Prepared by:

               E.H. Pechan & Associates, Inc.
               Rancho Cordova, CA 95742
               EPA Contract No. 68-D1-0146
            EPA Project Officer: Alice C. Gagnon
          Office of Air Quality Planning and Standards
                Office of Air And Radiation
            U.S. Environmental Protection Agency
             Research Triangle Park, NC 27711
                      April 1993

-------
                                         Disclaimer

This report has been reviewed by the Office of Air Quality Planning and Standards, U.S. Environmental
Protection Agency, and approved for publication.  Mention of trade names or commercial products does
                     not constitute endorsement or recommendation for use.

-------
                              TABLE OF CONTENTS
CHAPTER 1.  INTRODUCTION 	1-1
            1.1 BACKGROUND  	1-1

CHAPTER 2.  SOURCE DESCRIPTION 	2-1
            2.1    CHARACTERIZATION OF FIREPLACES   	2-1
            2.2    PROCESS DESCRIPTIONS 	2-1
            2.3    EMISSIONS  	2-2
            2.4    CONTROL TECHNOLOGY  	2-3
            REFERENCES  	2-4

CHAPTER 3.  GENERAL EMISSION DATA REVIEW AND ANALYSIS PROCEDURE	3-1
            3.1    DATA SEARCH AND SCREENING	3-1
            3.2    EMISSION DATA QUALITY RATING SYSTEM 	3-1
            3.3    EMISSION FACTOR QUALITY RATING SYSTEM	3-2
            REFERENCES  	3-4

CHAPTER 4.  EMISSION FACTOR DEVELOPMENT	4-1
            4.1    REVIEW OF EXISTING DATA SETS	4-1
                  4.1.1   References 1 through 10	4-2
            4.2    REVIEW OF NEW DATA SETS	4-3
                  4.2.1   Reference 11 - Fireplaces	4-3
            4.3    EMISSION FACTOR METHODOLOGY	4-3
                  4.3.1   Criteria Pollutant Emission Factor Development  	4-3
                        4.3.1.1       PM Emission Factor Development 	4-3
                  4.3.2   Noncriteria Pollutant Emission Factor Development	4-4
            4.4    EMISSION FACTOR RESULTS	4-5
            REFERENCES  	4-7

CHAPTER 5.  AP-42 SECTION 1.9: RESIDENTIAL FIREPLACES	5-1

APPENDIX A.  SAMPLE CALCULATIONS AND AWES-M5G CORRELATION EQUATION	 A-1

-------
1.  INTRODUCTION

1.1  BACKGROUND
      Emission factors are the basis for emission estimates made by State and local
air pollution control agencies, industry and manufacturers of pollution-generating
equipment. Beginning in 1972, the U.S. Environmental Protection Agency (EPA) has
published "Compilation of Air Pollutant Emission Factors" (AP-42) to make emission
factors available to regulators and industry. An emission factor relates the quantity
(weight) of a pollutant to a unit of activity from the source. Uses of AP-42 emission
factors include:
       !     Estimates of area-wide emissions;
       !     Emission estimates for a specific facility; and
       !     Evaluation of emissions relative to ambient air quality.
      This emission factor document provides background information and the analysis
used to review and revise emission factors located in AP-42 Chapter 1, Section  1.9:
Residential Fireplaces.  The current revision updates section 1.9 to include any new
data for criteria and noncriteria  pollutants.
      This report contains five  chapters, including the  introduction (Chapter 1).
Chapter 2 describes fireplaces, and characterizes fireplace combustion emissions and
controls.  Chapter 3 describes the procedure used to rank emission data and emission
factors. Chapter 4 explains the methodology used to review and revise emission
factors and includes an explanation of the  data base used to calculate emission factors.
Chapter 5 contains the actual, revised AP-42 section for residential fireplaces.
Appendix A includes sample calculations and EPA method 5G correlation equations.
Appendix B contains the last  revised section with hand-written remarks depicting the
changes  which were made as part of the current revision.
                                      1-1

-------
2.  SOURCE DESCRIPTION

      Residential wood combustion (RWC) is an emission category which primarily
consists of emissions from fireplaces and wood stoves. In some airsheds RWC
emissions can be the main source of air pollution and cause violations of the National
Ambient Air Quality Standard (NAAQS) for particulate matter (PM) with an aerodynamic
diameter of 10 //m  or less (PM-10). Regulations that control emissions from fireplaces
are relatively new,  compared to wood stove regulations, and exist only at the state or
local level.1  Fireplace regulation at the state level began in Washington State in 1991,
but exists elsewhere at mostly the local level (e.g., Reno,  Nevada, Fresno and
Mammoth Lakes, California).
2.1 CHARACTERIZATION OF FIREPLACES
      Homeowners enjoy the aesthetic effect a fireplace  has in a home.  Also, wood
burning fireplaces can be a source of supplemental heating for residences.  Fireplaces
are typically operated infrequently and for shorter periods of time compared to wood
stoves. There are  two basic types of fireplaces:  (1) masonry, and (2) prefabricated
[i.e., built-in metal type (zero-clearance or free-standing)].  A 1988 survey conducted for
the Consumer Product Safety Commission estimates that there are 19.1 million
fireplaces in use in the U.S.2 Of these, over 88 percent are characterized as masonry,
and 11 percent as  prefabricated.
2.2 PROCESS DESCRIPTIONS
      Fireplaces have a large, open firebox (i.e., generally the width is greater than the
height) with a damper above the firebox to control the intake of room air and limit heat
loss when the fireplace is inactive. Prefabricated fireplaces generally utilize doors and
a These values are based on the 1985 National Acid Precipitation Assessment Program (NAPAP)
estimates for RWC emissions, with the following assumptions based on discussions with RWC experts:
66 percent of the total RWC emissions are from wood stoves, 100 percent of the total suspended
particulate emissions are PM-10, and a 5 percent increase in all RWC pollutants since 1985 due to
growth which exceeds reductions from change-over to new technology stoves.
                                      2-1

-------
louvers to close off the firebox from the room and control air flow, thereby increasing
heating efficiency. Masonry fireplaces heat a room by radiation and may also utilize
doors. Therefore, combustion must release enough heat to transfer through fireplace
walls and heat the cool room air. Room air is cool because it is drawn in from the
outside to replenish the air which is drawn out through the chimney. 2.3 EMISSIONS
      Fireplace emissions, caused mainly by incomplete combustion, include
particulate matter (mainly PM-10), carbon monoxide (CO), oxides of sulfur (SOX), oxides
of nitrogen (NOX), volatile organic compounds (VOCs) and hazardous air pollutants
(HAPs),  including polycyclic organic material (POM).  POM is a class of compounds
containing carcinogens [e.g., benzo[a]pyrene (BaP)], which can be emitted as
condensable PM or in the vapor phase.  An important fuel characteristic which
contributes to fireplace PM-10 emissions is moisture content. Other important
characteristics which effect emissions are burn rate, flame intensity, and firebox shape
and size.
      One estimate indicates that the annual emissions from fireplaces in the U.S. are
0.4 million tons of PM-10, 2.3 million tons of CO, and 0.5 million tons of VOCs.a The
effects of these emissions are worsened two ways.  First, by adverse meteorology
during the wood burning season (i.e., wintertime temperature inversions). Second,
large regional variations in proportions of households actively using fireplaces (e.g.,
41.6% of the households in the Pacific region versus 19.4% of the households in the
Middle Atlantic region) also affect emissions.
2.4 CONTROL TECHNOLOGY
      In order to decrease PM and CO emissions from fireplaces, combustion must be
improved.  Combustion efficiency improves as burn rate and flame intensity increase.
Noncatalytic control techniques can accomplish this improvement.3   Noncatalytic
fireplace inserts reduce emissions by directing unburned hydrocarbons and CO into an
insulated secondary chamber, where mixing with fresh, preheated makeup air occurs
                                      2-2

-------
and combustion is enhanced.  (See Emission Factor Documentation for AP-42, Section
1.10, Residential Wood Stoves).
      Firebox shape and size also have an effect on emissions. As part of a recent
study to determine emissions from fireplaces, researchers performed tests on two
fireplaces which were retrofitted with a modified firebox (i.e., Rosin) that decreased the
size and altered the shape of the original firebox (i.e., made the firebox narrower at the
front, and not as deep).1 Results of these tests showed that the Rosin fireplaces had
PM emissions which were approximately one-half as much as a conventional fireplace.
      Although not a traditional control technology, the use of densified wood or
artificial "logs" has gained attention as a cleaner-burning fuel compared to cord wood.
The results of recent testing conducted in Canada on artificial log combustion in
fireplaces shows the potential to reduce particulate emissions by up to 84 percent, with
an accompanying reduction in CO  emissions of up to 92 percent.4
      In an attempt to combine a traditional fireplace with noncatalytic (i.e., secondary-
burn) technology, a manufactured fireplace has been developed.5 Early test results,
using EPA Method 28A, indicate that this fireplace has a particulate matter emission
rate of 5.5 g/hr, less than the EPA  allowable limit of 7.5 g/hr for Phase II noncatalytic
wood stoves.
                                      2-3

-------
REFERENCES FOR CHAPTER 2
1.     Barnett, S.G., In-Home Evaluation of Emissions From Masonry Fireplaces and
      Heaters, OMNI Environmental Services, Inc., Beaverton, OR, September 1991.

2.     Zamula, W.W., "Room Heating Equipment Exposure Survey, Final Report," U.S.
      Consumer Product Safety Commission, Directorate for Economic Analysis, OMB
      Control No. 3041-0083, Washington, DC,  March 1989.

3.     Guidance Document for Residential Wood Combustion Emission Control
      Measures, EPA-4502-89-015, U.S. Environmental Protection Agency, Research
      Triangle Park, NC, September 1989.

4.     Hayden, A., C.S. and R.W. Braaten, "Reduction of Fireplace and Woodstove
      Pollutant Emissions Through the Use of Manufactured Firelogs," Paper 91-
      129.1, Presented at the 84th Annual Meeting of the Air Waste Management
      Association, Vancouver, British Columbia, June 1991.

5.     Broome, F.H., "The Development of Clean-Burning, Noncatalytic Manufactured
      Fireplaces," Paper P1.6, Presented at the PM-10 Specialty Conference,
      Scottsdale, AZ, January 1992.
                                    2-4

-------
3.  GENERAL EMISSION DATA REVIEW AND ANALYSIS PROCEDURE

3.1  DATA SEARCH AND SCREENING
      The first step in updating the fireplace emission factor data base was to contact
RWC experts in order to determine if new test data were available since the last AP-42
update.1'2'3 A recent update of AP-42 emission factors for fireplaces provided a current
base on which to add new data.
3.2 EMISSION DATA QUALITY RATING SYSTEM
      The quality and quantity of the new test data were ranked pursuant to EPA
guidance and assigned a quality ranking based on the following criteria:4'5
      A - Tests performed using sound methodology and reported in enough detail to
          provide adequate validation.  These tests may not be EPA reference
          method tests, although such reference methods are preferred and to be
          used as a guide.
      B - Tests performed using sound methodology, but lacking enough detail to
          provide adequate validation.
      C - Tests performed using an unproven or new methodology, or are lacking a
          significant amount of background data.
      D - Tests performed using a generally unacceptable
          method, but the method may provide an order-of-magnitude value for the
          source.
      Guidelines to evaluate the data for sound methodology and adequate detail
were:
      !     Source operation.  The source was operating within typical parameters
            during the test and the parameters are well documented;
      !     Sampling procedures. If actual procedures deviated from standard
            methods during the test, the deviations are well  documented and
            evaluated to determine their influence on the test results;
                                     3-1

-------
       !     Sampling and process data.  If a large spread between test results cannot
            be explained by information contained in the test report, then the data are
            suspect and are given a lower rating; and
       !     Analysis and calculations.  The test reports should contain original raw
            data sheets. Nomenclature and equations used are compared with those
            specified by EPA to establish equivalency.  The depth of calculation
            review is determined  by the reviewers' confidence in the ability and
            conscientiousness of the tester.  Such ability is based on consistency of
            results and completeness of other areas of the test report.
3.3 EMISSION FACTOR QUALITY RATING SYSTEM
      After evaluating emissions data and calculating new emission factors, quality
rating of the emission factor was awarded based on the following criteria:
      A - Excellent: The emission factor was developed from only A-rated source data,
      and taken from many randomly chosen facilities.  The source category is specific
      enough to minimize variability within the source population.
      B - Above average: The emission factor was developed from only A-rated
      source data, but it is not clear if the facilities tested represent a random sample
      of the population.  As with the A-rated emission factor, the source category is
      specific enough to minimize variability within the source population.
      C - Average:  The emission factor was developed from only A- and B-rated
      source data, and from a reasonable number of facilities.  It is not clear if the
      facilities tested represent a random sample of the population. As with the A-
      rated emission factor, the source  category is specific enough to minimize
      variability within the source population.
      D - Below average: The emission factor was developed from only A- and B-
      rated source data, and from a small number of facilities. There may be reason to
      suspect that these facilities do not represent a random sample of the population.
      Also, there  may be evidence of variability with the source population. Any
                                      3-2

-------
limitations on the use of this emission factor are noted in the emission factor table.
E - Poor: The emission factor was developed from C- and D-rated source data.
There may be reason to suspect that the facilities tested do not represent a
random sample of the population. Also, there may be evidence of variability with
the source population. Any limitations on the use of this emission factor are
noted in the emission factor table.
                                3-3

-------
REFERENCES FOR CHAPTER 3
1.     Verbal Communication from Robert C. McCrillis, U.S. Environmental Protection
      Agency, Research Triangle Park, NC, to Paula G. Fields and George E. Weant,
      E.H. Pechan and Associates,  Inc., Rancho Cordova, CA, April-May, 1992.

2.     Written Communication from Stockton G. Barnett, OMNI Environmental Services,
      Inc., Beaverton, OR, to Paula G. Fields, E.H. Pechan and Associates, Inc.,
      Rancho Cordova,  CA, May 18, 1992.

3.     Written Communication from Paul Tiegs, OMNI Environmental Services, Inc.,
      Beaverton, OR, to George E. Weant, E.H. Pechan and Associates, Inc., Durham,
      NC, March 26, 1992.

4.     Technical Procedures for Developing AP-42 Emission Factors and Preparing
      AP-42 Sections, Office of Air Quality Planning and Standards, U.S.
      Environmental Protection Agency, Research Triangle Park, NC, March 1992.

5.     "Clarification to AP-42 Procedures Document," Memo from J. Southerland,
      Emission Factor and Methodologies Section, U.S. Environmental Protection
      Agency, Research Triangle Park, NC, April 1992.
                                    3-4

-------
4.  EMISSION FACTOR DEVELOPMENT

      This chapter describes the test data and methodology used to review and revise
the emission factors for residential fireplaces.  Previously existing fireplace test data
sets and new test data for fireplaces are discussed and evaluated.  The chapter ends
with a discussion of the revised emission factor data base.
4.1 REVIEW OF EXISTING DATA SETS
      The AP-42 emission factors for residential fireplaces were last reviewed and
revised in  September 1991, and subsequently published as part of AP-42, Supplement
D. As part of the 1991 revision, the data base of fireplace emissions testing results was
edited to include only recent test data.  During the current revision to AP-42, Chapter 1,
Section  1.9, the 1991 data base was reviewed to determine if it contained any
noncriteria emissions data and reviewed in order to evaluate the ratings of the existing
data since they will be combined with new emissions data.
      It is important to note these facts regarding the existing data base:  (1) All of
these data were collected under laboratory conditions or quasi-laboratory conditions
(i.e., testing was conducted in-home, but according to test protocol); (2) The final
average emission rate and emission factor are based on the emissions measured
during each burn cycle. These facts become relevant when determining how to
increase the existing data base by adding data collected in-home, where conditions are
"real-life,"  and emissions are reported as an average for each fireplace (i.e., averages
are based on several burn cycles).
      In-home data are generally preferred for use in emission factor development.
This is evidenced by the conversion from lab data to in-home data for determining
residential wood stove emission factors. More in-home fireplace data need to be
collected before the quality of all resultant emission data sets and emission factors can
be raised to the desired A-to-B range.
      It was decided during the review of the existing data base that the data should
be re-averaged  in order to determine the emission factor for each pollutant by fireplace
                                      4-1

-------
type instead of by burn cycle. This method of averaging provides a more accurate way
to combine the existing laboratory data with the new field data.  The ratings assigned to
the existing data and/or emission factors are shown in Table 4.1 at the end of this
chapter.
4.1.1  References 1 through 10
      Reference 1 contained PM, CO, hydrocarbon (HC or VOC), and C02 data from
fireplace testing conducted in Vail, Colorado during 1977. One of the fireplaces tested
had an electrostatic precipitator attached to the stack up-stream of the test ports; the
emissions data from this fireplace were dropped from the data base.
      Reference 2 contained PM, CO and polycyclic aromatic hydrocarbon (PAH) data
from fireplace testing conducted in Colorado during 1986-1987.  It was decided to not
include these data in the revised data base since the fueling protocol for this series of
tests included the use of dimensional wood only (i.e., Douglas fir nominal 4x4s and 3/4
x 3/4 inch strips) which is not representative of real-world fuel loads.
      Reference 3 contained PM and total nonmethane organic compound (TNMOC)
data from fireplace testing conducted in North Carolina during 1989.
      References 4, 5 and 6 contained CO, HC, aldehyde, and NOX data from fireplace
testing conducted by General Motors Research Laboratories.
      Reference 7 contained PM, CO, HC and POM data from the testing  of a
fireplace in Seattle, Washington in 1975. These data were averaged into one set of
emission factors for inclusion in the revised data base.
      Reference 8 contained CO and NOX data from the testing of a masonry fireplace
in California during 1980.
      References 9 and 10 contained average SOX and TNMOC data from the testing
of four fireplaces. The emission factor calculated from the results was reported as an
average by fireplace type.
4.2 REVIEW OF NEW DATA SETS
      One new data set of in-home fireplace test results were obtained.
4.2.1  Reference 11 - Fireplaces
                                      4-2

-------
      New in-home fireplace test data included emission rates for PM, CO and C02
from five fireplaces located in the Portland, Oregon area. The data from this test series
were assigned a rating of "A," since the test report provided documentation of sound
methodology in adequate detail.
4.3 EMISSION FACTOR METHODOLOGY
      A Lotus123J spreadsheet was used to compile emissions data and calculate
\emission factors. Print outs of the spreadsheet files and a disk copy of the
spreadsheet were placed in the emission factor background file.
4.3.1  Criteria Pollutant Emission Factor Development
      The emission factor for SOX was the only criteria pollutant emission factor that
did not change from the 1991 emission factor. The emission factors for PM-10, NOX,
VOCs, and CO were revised based on the addition of new data and/or the method used
to average the emissions by fireplace type instead of by burn  cycle.  Emission factors
were previously reported for methane and nonmethane VOCs, as well as total
hydrocarbons.
      The methane and nonmethane data (References 3, 7,  and 9) did not compare to
the total VOC data (References 1, 4, and 9) so it was decided not to use the methane
and nonmethane data for emission factor development. The previously reported
hydrocarbon emission factors were classified as total VOCs.
      4.3.1.1  PM Emission Factor Development. EPA Method 5H (M5H) is the  basis
for New Source Performance Standards (NSPS) for wood stoves.  It is also the
reference method used to evaluate fireplace emission test results. The new PM test
data were collected using a  modified Automated Wood Stove Emissions Sampler
(AWES), and related to the EPA Method 5G (M5G) by the following equation:
                         M5G = 0.8635 x (AWES)0'92™

After correcting AWES data to equivalent M5G values, the following equation converts
the M5G values to equivalent M5H values:
                           M5H = 1.619 x (M5G)0'905

                                     4-3

-------
      These equations were developed by performing a linear regression on data
taken from simultaneous AWES-M5G and M5G-M5H tests.12'13'14'15'16 A sample
calculation using these conversion equations along with the graphical results of the
linear regression of AWES-M5G data are shown in Appendix A. It should be noted that
the AWES-M5G tests were conducted on wood stoves having a maximum emission
rate of approximately 30 g/hr, while the maximum emission rate from the fireplace tests
to which the correlation equation was applied was approximately 83 g/hr. Even though
the AWES fireplace data are out of the range of the data used to develop the
correlation equation, it  is felt that the use of the equation on the fireplace data is
appropriate.  Emissions from another type of field wood stove emissions sampler
developed by Virginia Polytechnic Institute (VPI) have also been correlated with M5G
emissions using data collected while attaining emission rates greater than 80 g/hr. In
order to evaluate the accuracy of the AWES equation for emission rates greater than 30
g/hr, a comparison was made between the AWES-M5G equation and the VPI-M5G
equation for a given emission rate. Assuming an emission rate of 83 g/hr, the adjusted
M5H values are 52 and 58 g/hr for the AWES and VPI, respectively. The results
compare within about 10 percent, suggesting that use of the AWES-M5H equation for
emission rates in the 80 g/hr range may produce a slight understatement of the
emission factor.
4.3.2 Noncriteria Pollutant Emission Factor Development
      Emission factors for POM were not changed from the 1991 emission factors.
The emission factor ratings for POM  and aldehydes were revised based on the
methodology described in Chapter 3 of this report. A new emission factor for C02 was
calculated and the emission factor for aldehydes was revised to correct an error found
in the existing data base.
4.4 EMISSION FACTOR RESULTS
      Table 4-1 shows a summary of the new and revised emission factors for criteria
and noncriteria pollutants from residential fireplaces.
                                     4-4

-------
                TABLE 4-1. SUMMARY OF EMISSIONS DATA FROM RESIDENTIAL FIREPLACES
 Pollutant
   Previous
Emission Factor
    Rating
Revised Emission
  Factor Range
  New/Revised
Average Emission
     Factor
      g/kg
New/Revised
  Emission
Factor Rating
References
PM-10
Sulfur Oxides
Nitrogen Oxides
Carbon Monoxide
Carbon Dioxide
Total VOC
POM
Aldehydes
C
A
C
C
None
D
F
D
11.0-23.4
None
0.9-1.6
80.5-316.0
1459.1 -2248.1
2.9-184.3
None
None
17.3
0.2a
1.3
126.3
1699.4
114.5
8.03 E-4a
1.20
B
A
C
B
Cb
D
Ec
Ec
1,3,7,11
9,10
4,5,6,8
1,4,5,6,7,8,11
1,11
1,4,9
7
7
a.     This emission factor was not revised; the emission factor and rating is carried forward from the 1991 data base.
b.     Conversion of ppmv to kg/hr to g/kg was done using two different methods.  Details of analysis are contained in the
      emission factor background file.
c.     The average emission factor was developed from data gathered from a small number of fireplaces.
d.     The source data used to develop this emission factor showed a high degree of variability within the source
      population.

-------
REFERENCES FOR CHAPTER 4
1.     "Source Testing For Fireplaces, Stoves, And Restaurant Grills In Vail, Colorado,"
      EPA Contract No. 68-01-1999, Pedco Environmental, Inc., Cincinnati, OH,
      December 1977.

2.     Shelton, J.W., and L. Gay, Colorado Fireplace Report, Colorado Air Pollution
      Control Division, Denver, CO, March 1987.

3.     "Development Of AP-42 Emission Factors For Residential Fireplaces," EPA
      Contract No. 68-D9-0155, Advanced Systems Technology, Inc., Atlanta, GA,
      January 11, 1990.

4.     Jean M. Dash, "Particulate And Gaseous Emissions From Wood-burning
      Fireplaces," Environmental Science And Technology, 16(10):643-67, October
      1982.

5.     Lipari, F.,  et al., "Aldehyde Emissions From Wood-Burning Fireplaces,"
      Publication GMR-4377R, General Motors Research Laboratories, Warren, Ml,
      March 1984.

6.     Written communication from Robert C. McCrillis, U.S. Environmental Protection
      Agency, Research Triangle Park, NC, to Neil Jacquay, U.S. Environmental
      Protection Agency, San Francisco, CA,  November 19, 1985.

7.     Snowden, W.D., et al., "Source Sampling Residential Fireplaces For Emission
      Factor Development," EPA-450/3-76-010, U.S. Environmental Protection
      Agency, Research Triangle Park, NC, November 1975.

8.     Kosel, P., et al., Emissions From Residential Fireplaces, GARB Report C-80-027,
      California Air Resources Board, Sacramento,  CA, April 1980.

9.     DeAngelis, D.G., etal., Source Assessment:  Residential Combustion Of Wood,
      EPA-600/2-80-042b,  U.S.  Environmental Protection Agency, Cincinnati,  OH,
      March 1980.

10.    DeAngelis, D.G., et al., "Preliminary Characterization Of Emissions From Wood
      Fired Residential Combustion Equipment," EPA-600/7-80-040,  U.S.
      Environmental Protection Agency, Cincinnati,  OH, March 1980.

11.    Barnett, S.G., "In-Home Evaluation of Emissions From Masonry Fireplaces and
      Heaters,"  OMNI Environmental Services, Inc., Beaverton, OR, September 1991.
                                     4-6

-------
REFERENCES FOR CHAPTER 4 (Continued)
12.    Barnett, S.G., "Relationship of the AWES to EPA Methods 5H and 5G," OMNI
      Environmental Services, Inc., Beaverton, OR, December 1991.

13.    Burnett, P.G., "The Northeast Cooperative Woodstove Study," Volume 1, EPA-
      600/7-87-026a, U.S.  Environmental Protection Agency, Research Triangle Park,
      NC, November 1987.

14.    Cottone, L.E. and E.  Messer, "Test Method Evaluations and Emissions Testing
      for Rating Woodstoves," EPA-600/2-86-100, U.S. Environmental Protection
      Agency, Research Triangle Park, NC, October 1986.

15.    McCrillis, R.C., "Long-Term Wood Stove Catalysts Performance Under
      Simulated Residential Use," EPA-600/0-87-157, U.S. Environmental Protection
      Agency, Research Triangle Park, NC, June 1987.

16.    Memorandum from P.R. Westlin, U.S. Environmental Protection Agency,
      Research Triangle Park, NC, to J. Kowalczyk, Oregon Department of
      Environmental Quality, Portland, OR, July 13, 1986.
                                    4-7

-------
              5. AP-42 SECTION 1.9: RESIDENTIAL FIREPLACES
      The revision to Section 1.9 of AP-42 is presented in the following pages as it
would appear in the AP-42 document.
                                   5-1

-------
1.9 RESIDENTIAL FIREPLACES

1.9.1  General1'2

       Fireplaces are used primarily for aesthetic effects and secondarily as a supplemental heating
source in houses and other dwellings. Wood is the most common fuel for fireplaces, but coal and
densified wood "logs" may also be burned. The user intermittently adds fuel to the fire by hand.

       Fireplaces can be divided into two broad categories, 1) masonry (generally brick and/or stone,
assembled on site, and integral to a structure) and 2) prefabricated (usually metal, installed on site as a
package with appropriate duct work).

       Masonry fireplaces typically have large fixed openings to the fire bed and have dampers above
the combustion area in the chimney to limit room air and heat losses when the fireplace is not being used.
Some masonry fireplaces are designed or retrofitted with doors and louvers to reduce the intake of
combustion air during use.

       Prefabricated fireplaces are commonly equipped with louvers and glass doors to reduce the
intake of combustion air, and some are surrounded by ducts through which floor level air is drawn by
natural convection, heated and returned to the room. Many varieties of prefabricated fireplaces are now
available on the market. One general class is the freestanding fireplace, the most common of which
consists of an inverted sheet metal funnel and stovepipe directly above the fire bed. Another class is the
"zero clearance" fireplace, an iron or heavy gauge steel firebox lined inside with firebrick and
surrounded by multiple steel walls with spaces for air circulation.  Some zero clearance fireplaces can be
inserted into existing masonry fireplace openings, and thus are sometimes called  "inserts." Some of
these units are equipped with close fitting doors and have operating and combustion characteristics
similar to wood stoves. (See Section 1.10, Residential Wood Stoves.)

       Masonry fireplaces usually heat a room by radiation, with a significant fraction of the
combustion heat lost in the exhaust gases and through fireplace walls. Moreover, some of the radiant
heat entering the room goes toward warming the air that is pulled into the residence to make up for that
drawn up the chimney. The net effect is that masonry fireplaces are usually inefficient heating devices.
Indeed, in cases where combustion is poor, where the outside air is cold, or where the fire is allowed to
smolder (thus drawing air into a residence without producing appreciable radiant heat energy), a net heat
loss may occur in a residence using a fireplace. Fireplace heating efficiency may be improved by a
number of measures that either reduce the excess air rate or transfer back into the residence some of the
heat that would normally be lost in the exhaust gases or through  fireplace walls. As noted above, such
measures are commonly incorporated into prefabricated units. As a result, the energy efficiencies of
prefabricated fireplaces are slightly higher than those of masonry fireplaces.
1.9.2  Emissions1"13

       The major pollutants of concern from fireplaces are unburnt combustibles, including carbon
monoxide, gaseous organics and particulate matter (i.e., smoke).  Significant quantities of unburnt
combustibles are produced because fireplaces are inefficient combustion devices, with high uncontrolled
excess air rates and without any sort of secondary combustion.  The latter is especially important in wood


4/93                              External Combustion Sources                              1.9-1

-------
burning because of its high volatile matter content, typically 80 percent by dry weight. In addition to
unburnt combustibles, lesser amounts of nitrogen oxides and sulfur oxides are emitted.

        Hazardous Air Pollutants (HAPs) are a minor, but potentially important component of wood
smoke.  A group of HAPs known as polycyclic organic matter (POM) includes potential carcinogens
such as benzo(a)pyrene (BaP). POM results from the combination of free radical species formed in the
flame zone, primarily as a consequence of incomplete combustion. Under reducing conditions, radical
chain propagation is enhanced, allowing the buildup of complex organic material such as POM. The
POM is generally found in or on smoke particles, although some sublimation into the vapor phase is
probable.

        Another important constituent of wood smoke is creosote. This tar-like substance will burn if
the fire is hot enough, but at insufficient temperatures, it may deposit on surfaces in the exhaust system.
Creosote deposits are a fire hazard in the flue, but they can be reduced if the chimney is insulated to
prevent creosote condensation or if the chimney is cleaned regularly to remove any buildup.

        Fireplace emissions are highly variable and are a function of many wood characteristics and
operating practices.  In general, conditions which promote a fast burn rate and a higher flame intensity
enhance secondary combustion and thereby lower emissions. Conversely, higher emissions will result
from a slow burn rate and a lower flame intensity. Such generalizations apply particularly to the earlier
stages of the burning cycle, when significant quantities of combustible volatile matter are being driven
out of the wood. Later in the burning cycle, when all volatile matter has been driven out of the wood, the
charcoal that remains burns with relatively few emissions.

        Emission factors and their ratings for wood combustion in residential fireplaces are given in
Tables 1.9-1. and 1.9-2.
1.9-2                               EMISSION FACTORS                                4/93

-------
      Table 1.9-1. (ENGLISH UNITS) EMISSION FACTORS FOR WOOD COMBUSTION IN
                                 RESIDENTIAL FIREPLACES
                           (Source Classification Code: 2104008001)
 Device
Pollutant
Emission Factor3
     Ib/ton
Rating
Fireplace PM-10b
Carbon Monoxide0
Sulfur Oxidesd
Nitrogen oxides6
Carbon Dioxidef
Total VOCsg
POMh
Aldehydesk
34.6
252.6
0.4
2.6
3400
229.0
1.6E-3
2.4
B
B
A
C
C
D
EJ
EJ
"Units are in Ibs. of pollutant/ton of dry wood burned.
bReferences 2, 5, 7, 13; contains filterable and condensable particulate matter (PM); PM emissions are
considered to be 100% PM-10 (i.e., PM with an aerodynamic diameter of 10/mi or less).
"References 2, 4, 5, 9, 13.
References 1, 8.
References 4, 9; expressed as NO2.
References 5, 13
8References 4-5,8.  Data used to calculate the average emission factor were collected by various
methods. While the emission factor may be representative of the source population in general, factors
may not be  accurate for individual sources.
Reference 2.
JData used to calculate the average emission factor were collected from a single fireplace and are not
representative of the general source population.
References 4,11.
4/93
               External Combustion Sources
                              1.9-3

-------
       Table 1.9-2. (METRIC UNITS) EMISSION FACTORS FOR WOOD COMBUSTION IN
                                 RESIDENTIAL FIREPLACES
                           (Source Classification Code: 2104008001)
Device
Fireplace







Pollutant
PM-10b
Carbon Monoxide0
Sulfur Oxidesd
Nitrogen oxides6
Carbon Dioxidef
Total VOCsg
POMh
Aldehydesk
Emission Factor3
R/kg
17.3
126.3
0.2
1.3
1700
114.5
0.8E-3
1.2
Rating
B
B
A
C
C
D
EJ
EJ
"Units are in grams of pollutant/kg of dry wood burned.
bReferences 2, 5, 7, 13; contains filterable and condensable particulate matter (PM); PM emissions are
considered to be 100% PM-10 (i.e., PM with an aerodynamic diameter of 10/^m or less).
"References 2, 4, 5, 9, 13.
References 1, 8.
References 4, 9; expressed as NO2.
References 5, 13
8References 4-5,8.  Data used to calculate the average emission factor were collected by various
methods. While the emission factor may be representative of the source population in general, factors
may not be accurate for individual sources.
Reference 2.
JData used to calculate the average emission factor were collected from a single fireplace and are not
representative of the general source population.
References 4,11.
1.9-4
EMISSION FACTORS
4/93

-------
References for Section 1.9

 1.     DeAngelis, D.G., et al., Source Assessment: Residential Combustion Of Wood. EPA-
       600/2-80-042b, U.S. Environmental Protection Agency, Cincinnati, OH, March 1980.

2.      Snowden, W.D., et al., Source Sampling Residential Fireplaces For Emission Factor
       Development EPA-450/3-76-010, U.S. Environmental Protection Agency, Research
       Triangle Park, NC, November 1975.

3.      Shelton, J.W., and L. Gay, Colorado Fireplace Report. Colorado Air Pollution Control
       Division, Denver, CO, March 1987.

4.      Dasch, J.M., "Particulate And Gaseous Emissions From Wood-burning Fireplaces,"
       Environmental Science And Technology. 16(10):643-67, October 1982.

5.      Source Testing For Fireplaces. Stoves. And Restaurant Grills In Vail. Colorado. EPA
       Contract No. 68-01-1999, Pedco Environmental, Inc., Cincinnati, OH, December 1977.

6.      Written communication from Robert C. McCrillis, U.S. Environmental Protection
       Agency, Research Triangle Park, NC, to Neil Jacquay, U.S. Environmental Protection
       Agency, San Francisco, CA, November 19, 1985.

7.      Development Of AP-42 Emission Factors For Residential Fireplaces. EPA Contract No.
       68-D9-0155, Advanced Systems Technology, Inc., Atlanta, GA, January 11, 1990.

8.      DeAngelis, D.G., et al., Preliminary Characterization Of Emissions From Wood Fired
       Residential Combustion Equipment. EPA-600/7-80-040, U.S. Environmental Protection
       Agency, Cincinnati, OH, March  1980.

9.      Kosel, P., et al., Emissions From Residential Fireplaces. CARB Report C-80-027,
       California Air Resources Board,  Sacramento, CA, April 1980.

10.    Clayton, L., et al., Emissions From Residential Type Fireplaces. Source Tests 24C67,
       26C, 29C67, 40C67, 41C67, 65C67 and 66C67, Bay Area Air Pollution Control District,
       San Francisco, CA,  January 31, 1968.

11.    Lipari, F., et al., Aldehyde Emissions From Wood-Burning Fireplaces. Publication GMR-
       4377R, General Motors Research Laboratories, Warren, MI, March 1984.

12.    Hayden, A., C.S., and R.W. Braaten, "Performance Of Domestic Wood Fired
       Appliances," Presented at the 73rd Annual Meeting of the Air Pollution Control
       Association, Montreal, Quebec, Canada, June 1980.

13.    Barnett. S.G.. In-Home Evaluation of Emissions From Masonry Fireplaces and Heaters.
       OMNI Environmental Services, Inc., Beaverton, OR, September 1991.

4/93                           External Combustion Sources                           1.9-5

-------
APPENDIX A
     SAMPLE CALCULATIONS AND AWES-M5G CORRELATION EQUATION

-------
                            SAMPLE CALCULATIONS
GIVEN:
      Particulate sampling using AWES unit
                                                    P-
                              Emission Rate  =  85.4 —
                                                   la-
                                Burn Rate = 4.17
                                                 hr
FIND:
      Equivalent M5H Emission Factor (g/kg, Ib/ton)

SOLUTION:
Convert AWES g/hr to M5G equivalent

                         M5G  =  0.8635(85.4)9288 = 53.7 g/hr

Convert M5G to M5H equivalent

                         M5H = 1.619(53.7)0'905 =  59.6 g/hr
Calculate g/kg (Ib/ton)

                          59.6 g/hr  =
                         4.17 kg/hr
                                        A-2

-------
LINEAR REGRESSION FOR DEVELOPMENT OF "AWES" to M5G COORELATION


Septembers, 1992

AWES


======
Reference:



5G

23.3
3.15
1.5
2.47
0.74
0.74
12.9
17.4
6.73
11.82
3.21
5.95
6.2
4.43




LN5G

3.1484533606
1.1474024528
0.4054651081
0.9042181506
-0.301105093
-0.301105093
2.5572273114
2.8564702062
1.9065751437
2.469793012
1.1662709371
1.7833912196
1.8245492921
1.4883995841




= = = = =



























S.G. Barnett, "Relationship of the AWES to EPA Methods 5H and 5G"
OMNI Environmental Services, December 15, 1991

Prepared for R.C. McCrillis, U.S. EPA, AEERL, RTF, NC 2771 1

AWES

27.1
3.5
4.1
4.2
0.87
0.8
22.3
22.4
9.25
17.13
2.6
9.5
6.61
4.35


LN AWES

3.29953372789
1.2527629685
1.41098697371
1.43508452529
-0.1392620673
-0.2231435513
3.10458667847
3.10906095886
2.22462355152
2.84083131234
0.95551144503
2.25129179861
1.88858365386
1.4701758451























Constant






Regression Output:

StdErrofYEst
R Squared

No. of Observations
Degrees of Freedom


X Coefficients)
StdErrofCoef.
R
=======



5G = C * (AWES) AA
C = exp(Constant)=
A = X Coefficient=






0.9288379
0.0748238
0.9631998



0.8635
0.9288
5G = 0.8635*(AWES)A0.9288













-0.146719
0.3029377
0.9277539
14
12










A-3

-------


For Graphing:
Sorted "X"
0.8
0.87
2.6
3.5
4.1
4.2
4.35
6.61
9.25
9.5
17.13
22.3
22.4
27.1






































Sorted "Y"
0.74
0.74
3.21
3.15
1.5
2.47
4.43
6.2
6.73
5.95
11.82
12.9
17.4
23.3








































5G = 0.8635*(AWES)A0.9288
0.702
0.759
2.098
2.765
3.202
3.275
3.383
4.99
6.818
6.989
12.08
15.44
15.5
18.5
















































































































EMISSION FACTORS    A-4
4/93

-------
REPORT ON REVISIONS TO
      5TH EDITION AP-42
            Section 1.9
      Residential Fireplaces
  Contract No. 68-D2-0160, Work Assignment 50
   EPA Work Assignment Officer: Roy Huntley
   Office of Air Quality Planning and Standards
          Office of Air and Radiation
     U. S. Environmental Protection Agency
  Research Triangle Park, North Carolina 27711
               Prepared by:

          Eastern Research Group
           Post Office Box 2010
       Morrisville, North Carolina 27560
              July 29, 1996

-------
                                    Table of Contents

                                                                                     Page

1.0    INTRODUCTION	1-1

2.0    REVISIONS	2-1

       2.1     General Text Changes  	2-1
       2.2     Criteria Pollutant and Miscellaneous Emission Factors  	2-1
       2.3     Greenhouse Gases  	2-1
              2.3.1   Carbon Dioxide, CO2	2-1
              2.3.2   Methane, CH4	2-1
              2.3.3   Nitrous Oxide, N2O 	2-1

3.0    REFERENCES  	3-1
7997\92\04\Suplemnt.B\Reports\Chptr01\01-09.001 (3-18-99)          111

-------
1.0    INTRODUCTION

       This report supplements the Emission Factor (EMF) Documentation for AP-42 Section
1.9, Residential Fireplaces, dated September 1991.  The EMF describes the source and rationale
for the material in the most recent updates to the 4th Edition, while this report provides
documentation for the updates written in both Supplements A and B to the 5th Edition.

       Section 1.9 of AP-42 was reviewed by internal peer reviewers to identify technical
inadequacies and areas where state-of-the-art technological advances need to be incorporated.
Based on this review, text has been updated or modified to address any technical inadequacies or
provide clarification. Additionally, emission factors were checked for accuracy with information
in the EMF Document and new emission factors generated if recent test data were available.

       If discrepancies were found when checking the factors with the information in the EMF
Document, the appropriate reference materials were then checked.  In some cases, the factors
could not be verified with the information in the EMF Document or from the reference materials,
in which case the factors were not changed.

       Four sections follow this introduction.  Section 2 of this report documents the revisions
and the basis for the changes. Section 3 presents the references for the changes documented in
this report. Section 4 presents the revised AP-42 Section 1.9, and Section 5  contains the EMF
documentation dated April 1993.
7997\92\04\Suplemnt.B\Reports\Chptr01\01-09.001 (3-18-99)
                                           1-1

-------
2.0    REVISIONS

       This section documents revisions made to Section 1.9 of the 5th Edition of AP-42.

2.1    General Text Changes

       Minor changes were made to the text concerning emission controls based on information
in the EMF Document. Also, at the request of EPA, metric units were removed.

2.2    Criteria Pollutant and Miscellaneous Emission Factors

       The criteria pollutant emission factors (PM-10, CO, SOX, and NOX) were checked against
information in Table 4-1 and no changes were necessary. Also, there were no changes made to
other miscellaneous factors (Total VOC, POM, or aldehydes).

2.3    Greenhouse Gases

2.3.1   Carbon Dioxide, CO2

       The CO2 factors remain the same as in the 1/95 version of AP-42.

2.3.2   Methane, CH4

       No emissions data was found.

2.3.3   Nitrous Oxide, N2O

       Only one reference listed N2O emissions for residential fireplaces.  The source data for
this factor was not available for review, so the factor retains and "E" rating.
7997\92\04\Suplemnt.B\Reports\Chptr01\01-09.001 (3-18-99)
                                           2-1

-------
                 Table 1.  N2O Emission Factors for Residential Fireplacesa
                                      (Ib N2O/ton wood)
Combustion Category
Domestic (furnaces and fireplaces
EF Rating
E
EF
0.3
AP-42 EF
None
 aReference 1.
7997\92\04\Suplemnt.B\Reports\Chptr01\01-09.001(3-18.
                                  -99EMISSIOMACTORS
4/93

-------
3.0    REFERENCES
      Ortech Corporation, Inventory Methods Manual For Estimating Canadian Emissions Of
      Greenhouse Gases, Prepared for Environmental Canada, 1994.
                                       4-1

-------