-------
Disclaimer

The United States Environmental Protection Agency through its Office of Research
and  Development  funded  and managed the  research described here  under
Interagency Agreement DW-89-92261601 with the U. S. Department  of Energy
(DOE). It has been reviewed by the Agency and approved for publication. The views
expressed in this paper do not necessarily reflect the views or policies of the Agency
or Lawrence  Livermore National Security,  LLC.  Mention  of trade  names  or
commercial products does not constitute endorsement or recommendation for use.
EPA does not endorse the purchase or sale of any commercial products or services.
Neither the United States government nor Lawrence Livermore National Security,
LLC, nor any of their employees makes any warranty,  expressed or implied, or
assumes any  legal  liability or responsibility for the accuracy, completeness, or
usefulness of any information, apparatus, product, or process disclosed, or represents
that its use would not infringe privately owned rights.
Auspices Statement

This work was performed under the auspices of the U.S. Department of Energy by
Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344;
the Lawrence Livermore National Laboratory report number is LLNL-TR-642422.
The research team was  composed of Maureen Alai, Carolyn Koester and Donald
MacQueen.

-------
Acknowledgments

The authors wish to acknowledge the support of all those who helped plan and
prepare this report. We also acknowledge Ro Leif of Lawrence Livermore National
Laboratory for executing the ampoule sealing and for his helpful technical assistance
and insights.
                                                                       in

-------
Abbreviations/Acronyms


CCV - continuing calibration verification

CWA - Chemical Warfare Agent

DCC - dicyclohexylcarbodiimide

DCM - dichloromethane

(DES)2 -bis[2-(diisopropylamino)ethyl] disulfide, formula

DESH - 2-(N,N-diisopropylamino)ethanethiol, formula

DFTPP - decafluortriphenylphosphine, formula Cig

DIG - diisopropylcarbodiimide

DOE - United States Department of Energy

EPA - United States Environmental Protection Agency

ERLN - Environmental Response Laboratory Network

EMPA - ethylmethylphosphonic acid

FPD - flame photometric detector

GC - gas chromatograph

GC-FPD - gas chromatography  coupled with flame photometric detection

GC/MS - gas chromatography/mass spectrometry

IMPA - isopropyl methylphosphonic acid

LLNL - Lawrence Livermore National Laboratory

MS - mass spectrometer

NMR - nuclear magnetic resonance (spectroscopy)

PFTBA - perfluorotributylamine, formula Ci2P27N

Pyro A - O,O-diethyl dimethylpyrophosphonate, formula
Pyro B - O-ethyl, O-isopropyl dimethylpyrophosphonate, formula CvHigtMV/X - O-ethyl-S-(2-
diisopropylaminoethyl) methylphosphonothioate, formula CnH26NO2PS

VOA - volatile organic analysis

VX - O-ethyl-S-(2-diisopropylaminoethyl) methylphosphonothioate
                                                                                                 IV

-------
                                    Executive Summary

Lawrence Livermore National Laboratory (LLNL) supplies ultra-dilute (10 (ig/mL) chemical warfare agent
(CWA) standards to the Environmental Response Laboratory Network (ERLN) laboratories to allow the
use of authentic standards to assist in analyses required for a remediation event involving CWAs. These
standards are  synthesized  by Lawrence Livermore National Laboratory specifically for the ERLN
laboratories and are not commercially produced. For this reason, it is important to collect data regarding
the shelf-lives of these standards.  In a previous study (U.S. EPA, 2013), data collected by LLNL suggested
that VX (O-ethyl-S-(2-diisopropylaminoethyl) methylphosphonothioate) was not stable over the long-term
(e.g., greater than a month) when mixed with other CWAs, including sarin. Even stored as a single-analyte
10-(ig/mL solution, the stability of VX in screw-capped vials was inconsistent. This instability has the
potential to impact quality  control in regional ERLN laboratories, resulting in data that are difficult to
interpret. Thus, this study investigated the use of chemical stabilizers to increase the shelf-life of VX
standards.  VX standards with long shelf-lives are desirable, as long shelf-life would significantly reduce
costs needed to ensure ERLN laboratory preparedness for VX is possible.

The goal of this work was to determine the efficacy of two stabilizers — diisopropylcarbodiimide (DIG)
and dicyclohexylcarbodiimide (DCC) — for 10 (ig/mL VX in dichloromethane (DCM) compared to a VX
solution without any added stabilizer. We investigated the use of the stabilizers at concentrations of 1 (ig/mL
and 10 (ig/mL.  For these studies, the ultra-dilute VX standards were stored in both flame-sealed ampoules
and 2-mL,  Teflon®-lined, screw-capped vials. All standards were stored at 4 °C ± 2 °C for the twelve-
month duration of the study. This temperature was selected to be representative of the storage conditions
used by the ERLN laboratories. As the previous study had suggested that water in the solvent may be partly
responsible for VX degradation, the water concentration of dried DCM was monitored when DCM was
stored in 40-mL VOA vials  and repeatedly opened and analyzed at each sampling point.

After  the VX standards were prepared in DCM, 1-mL aliquots were transferred to amber glass ampoules
and flame-sealed  or  transferred to screw-capped  vials. Triplicate ampoules/vials  were opened  at
predetermined times and VX, DIC, and DCC concentrations were measured by gas chromatography/mass
spectrometry (GC/MS) and  by gas chromatography coupled with flame photometric detection (GC-FPD).
Concentrations were plotted as a function of time over the course of twelve months.  Dunnett's  test was
used to determine if statistically significant decreases were observed in VX concentrations for the GC-FPD
data collected during the course of the study.  Water concentration in the DCM was  measured by
coulometric Karl Fischer titration.

Results  of Dunnett's test (a=0.01) indicated that no continuing statistically significant decreases in VX
concentrations occurred during the first 9 months of the study for any of the  storage conditions tested;
however, several random statistically significant decreases in VX concentrations were observed.  By the
twelfth month of the study, statistically significant degradation of VX (although still within -20% of the
original concentration) was observed for seven of the ten samples. Based on these data, it is recommended
that laboratories  restock their VX standards every 6-9 months.  It is also  recommended that laboratories
check (by analysis) the concentrations of VX  standards prior to use to test for the possibility of receiving a
standard that is not at its expected concentration. Data suggest that the use of a stabilizer was not warranted
and no preference for storage of VX standards in sealed ampoules versus screw-capped vials exists. Based
on the complexity and potential complications (soot formation,  overpressure with purge gas, etc.) with
flame sealing, it is recommended to store and ship standards in screw-capped vials. DCM was observed to
absorb water from the environment suggesting that, when in use, vials of standards should be left  open for
as short a period as possible.

-------
                                 Table of Contents

Disclaimer	ii
Auspices Statement	ii
Acknowledgments	iii
Abbreviations/Acronyms	iv
Executive Summary	v
Introduction	1
Materials and Methods	5
  Preparation of Standards	5
  Ampoule Sealing	6
  Instrumentation	7
  Analytical Procedure	7
  Quantitation of Target Analytes	9
Results and Discussion	9
Conclusions	19
References	21
                                                                                   VI

-------
                                    Introduction

The  Environmental  Response  Laboratory Network (ERLN)  is  EPA's  national network of
laboratories that can be accessed as needed to support large scale environmental responses. With
the threat of a chemical, biological, and radiological attack to the United States becoming more
complex, the need for accurate, timely environmental testing capabilities becomes even more
crucial.  Ultra-dilute (10  jig/mL)  chemical warfare agent (CWA)  standards are supplied by
Lawrence Livermore National Laboratory (LLNL) to Environmental  Response  Laboratory
Network (ERLN) laboratories to allow the use of authentic standards to assist in analyses required
in remediation after an incident involving CWAs.  As these standards are synthesized by LLNL
specifically for the ERLN laboratories and  are not commercially produced, knowledge regarding
the shelf-lives of these standards is limited.  Stability data collected by LLNL suggest that O-ethyl-
S-(2-diisopropyl-aminoethyl) methylphosphonothioate (VX) is not stable over the long-term (e.g.,
more than a month) when mixed with sarin, soman, cyclosarin, or sulfur mustard (U.S. EPA, 2013).
Previous investigations suggest that when stored  as a single-analyte, 10  |ig/mL  solution in
dichloromethane (DCM), VX in sealed vials was stable for only two months (20 % degradation of
VX was observed  by the third month of the  study), with measurements  at longer time-points
yielding inconsistent results (e.g., VX in one vial had disappeared, while VX in a duplicate vial
appeared to be stable, yielding an overall degradation of approximately 80 % after a year). VX
standards in DCM that were stored in sealed ampoules appeared to be stable for a year;  however,
similarly-stored, sealed-ampoule,  single-analyte  solutions of VX in hexane showed -20 %
degradation after three months (U.S. EPA, 2013). The instability of VX has the potential  to impact
quality control in ERLN laboratories, yielding results that are difficult to interpret and possible
misinterpretation of data. Thus, this study investigated the use of chemical  stabilizers to increase
the shelf-life of VX standards. VX standards with long shelf-lives are desirable, as long shelf lives
for the standards that are produced would  significantly reduce the costs associated with ERLN
laboratory preparedness for VX.

The stability of VX can be reduced by reactions with water and other contaminants introduced in
its manufacturing process and by the reaction of degradation products in the VX solution. Buckles
et al. (1977),  Pardasani et al. (2010),  Black and Muir (2003), Munro et al. (1999), Yang (1999)
and Yang et al. (1996) describe various processes of VX degradation that are based on its reactions
with water, contaminants, and degradation products. Figures 1 through 3 show several degradation
reactions   for  VX.  U.S.   EPA  (2013)   confirmed  experimentally  that   O,O-diethyl
dimethylpyrophosphonate (Pyro A) was produced by reaction of VX and ethyl methylphosphonic
acid (EMPA) in  a  single-component standard;  the presence  of EMPA itself indicated  that
hydrolysis was a mechanism  for VX degradation in the standards.  That study also confirmed that
the breakdown of VX in a multiple-component standard solution was initiated by the presence of
isopropyl methylphosphonic  acid (IMPA) where the initial attack on VX by IMPA initiates the
autocatalytic breakdown cycle of VX, as seen in Figure 3.

-------
      ,.
      H3C   NS-
                                            o

                                            JL-OCHaCHa
                       CH{CH3)2
               vx
EMPA
          Figure 1. VX reaction with water to produce EMPA.
                 VX
             HS.
                 DESH
                    DESH
         T
                 (DES)2
                                      EMPA
Figure 2. Autocatalytic degradation mechanism for VX initiated by EMPA.

-------
       o-i
             vx
            DESH
           [O]
                DESH
EMPA - Ethyl methylphosphonic acid
IMPA - Isopropyl methylphosphonic
        acid
Pyro A - O,O-Diethyl dimethyl-
        pyrophosphonate
Pyro B - O-Ethyl, O-isopropyl-
        dimethylpyrophosphonate
DESH - 2-(N,N-diisopropylamino)-
        ethanethiol
(DES)2 - 6/'s[2-(diisopropylamino)-
        ethyl] disulfide
            (DES)2
                                EMPA
                                   VX
                                               IMPA
                      Autocatalytic degradation for VX
                      initiated by EMPA; see Figure 2.
     Figure 3. Autocatalytic degradation mechanism for VX
                      initiated by IMPA.
Given the above degradation pathways, a desirable stabilizer would be one that could react with
both water  and the relevant contaminants or directly  stabilize the  VX.  Buckles et al. (1977),
Rosenblatt et al. (1996), and Rohrbaugh (1998) identified carbodiimide stabilizers as appropriate
for VX. The rate of reaction of the stabilizers with residual water/contaminants was faster than the
rate of reaction of the water/contaminants with VX. Because diisopropylcarbodiimide (DIG) and
dicyclohexylcarbodiimide  (DCC) were  identified as   stabilizers  commonly  used  for VX
stabilization, these stabilizers were selected for this study.

-------
The  goal of this work is  to determine effective stabilization strategies for VX in ultra-dilute
(10-|ig/mL) standards.  To achieve this goal, the study objectives are defined as:

       •   Investigate VX stability in standards of 10 |ig/mL VX in dichloromethane (DCM),
          stored in flame sealed ampoules at 4 °C for 12 months. These standards were made
          using several different preparations, including:

          a)  No stabilizer (control experiments)
          b)  The stabilizer DIG at 1 |ig/mL
          c)  The stabilizer DIG at 10 |ig/mL
          d)  The stabilizer DCC at 1 jig/mL
          e)  The stabilizer DCC at 10 jig/mL.
       •   Study the stability of standards of 10 ng/mL VX in DCM in 2-mL, Teflon®-lined,
          screw-capped vials at 4 °C for 12 months. As above, these standards were prepared in
          varying ways, including:

          a)  No stabilizer (control experiments)
          b)  The stabilizer DIG  at 1 |ig/mL
          c)  The stabilizer DIG at 10 |ig/mL
          d)  The stabilizer DCC at 1 jig/mL
          e)  The stabilizer DCC at 10 jig/mL.

       •   Determine the water concentration in dried DCM when DCM is stored in 40-mL VOA
          vials and repeatedly opened and analyzed at various sampling points to understand the
          potential water exposure of VX standards under conditions of simulated laboratory use.

Under the conditions described  above, we could determine whether the presence of a stabilizer
increased the amount of time that VX remained stable in a 10 ng/mL solution, relative to a VX
solution with no added stabilizer.   This study considers two sets  of storage conditions —
untouched, in flame-sealed glass ampoules  (reflecting the manner in which the standards  are
shipped to the CWA laboratories, with the exception that standards are currently  shipped at
ambient temperature) and standards that are stored in screw-cap vials (which reflects the handling
of standards that are "in use" by the  laboratory).   An analyte concentration of 10 |ig/mL was
selected for study because this concentration represents the maximum concentration of VX that
can currently be handled in the  EPA CWA laboratories. To determine VX stability in solution
with a chemical  stabilizer, large batches of 10 |ig/mL solutions were made, and 1-mL aliquots
were  flame-sealed in multiple  amber glass ampoules or stored in screw-capped  vials.   At
predetermined intervals over the course of a year, ampoules or vials of the standards were opened
and analyzed and the amounts of VX remaining in the standards were quantified to determine VX
stability. This report covers the twelve months of observations.

-------
                             Materials and Methods
Preparation of Standards
Standards of 10 |ig/mL of VX in DCM were made containing either no stabilizer, a stabilizer
concentration of 1 |ig/mL, or a stabilizer concentration of 10  |ig/mL. DCM used for making
standards was obtained from Sigma-Aldrich (catalog number 34488, Fluka brand, which contains
25 mg/L amylene as a stabilizer). DCM was dried using a solvent distillation method with calcium
hydride (Li  et al.,  2007) as a desiccant and refluxed  over two days (Figure 4).   While use of
molecular sieves was considered for producing dry DCM, preliminary experiments suggested that
the presence of molecular sieves may contribute to VX disappearance in a sample. To avoid the
potential problem of VX disappearance as the result of molecular sieve use, solvent distillation
was  used to dry DCM. The water  concentration remaining in  the  DCM used for standard
preparation was determined by titration with an Aquamax Coulometric Karl Fischer Titrator (GR
Scientific Ltd., Bedfordshire, United Kingdom) with a detection limit for water as low as 1 |ig/mL.
After drying the stock DCM, the measured concentration for water  in the dried DCM used for
preparing the VX standards was 25 |ig/mL (the concentration of water in DCM  fresh from the
bottle was measured as 91 jig/mL; the water content for a bottle of DCM that was left open in the
laboratory for 3 hours was 380 |ig/mL).

Water content of the dried stock DCM was monitored during the course of the study.  DCM was
stored in a total of eleven 40-mL VOA vials, one vial for each sampling time point.  The VOA
vials were sealed with Teflon-lined silicone septa, similar to the septa used to seal the autosampler
vials used to store the standard solutions containing VX.  Because  of the fragile nature of the
ceramic frit  and platinum electrode on the Karl Fischer Titrator and because of potential issues
with decontamination of the electrode after exposure to VX, the standard samples  containing VX
and the stabilizers were not analyzed for water content. Thus, we have  assumed that any changes
in water content over time exhibited by the DCM in VOA vials would be similar to changes in
water content exhibited by the VX standard samples.

VX used for this study was synthesized by LLNL and  determined to be 96.0 % pure1 by nuclear
magnetic resonance spectroscopy (NMR, 600 MHz, Advance III, Bruker, Billerica, MA) and gas
chromatography/mass spectrometry (GC/MS, Model 5975, Agilent  Technologies, Santa Clara,
CA) analyses.  Impurities were identified by direct GC/MS analysis (non-polar compounds) and
also  by  using N,O-bis(trimethylsilyl)trifluoroacetamide (Sigma-Aldrich,  product  no. 33024, St.
Louis, MO)  to form trimethylsilyl derivatives of polar compounds, which were then identified by
GC/MS. Dilute standards were prepared gravimetrically from neat materials. Concentrations were
also  verified by GC-FPD analysis (7890A GC interfaced with a single P-channel FPD, Agilent
Technologies, Santa  Clara, CA), which allowed the  comparison of phosphorus signal responses
against those of certified reference materials (e.g., malathion, Fluka, product no. 31558, available
from Sigma-Aldrich, St. Louis, MO).

All standards were refrigerated (4 °C ± 2 °C) until analysis to mimic  storage conditions expected
to be used by the laboratories.  The refrigerator was equipped with a thermometer (part number
1 VX impurities identified by GC/MS include O,S-diethyl methylphosphonothioate, diisopropylethyl
mercaptoamine (detected as trimethylsilyl derivative), O-ethyl methylphosphonothioate (also identified as
trimethylsilyl derivative), diisopropylaminoethyl chloride, and bis(diisopropylaminoethyl)disulfide.

-------
20700T, H-B Instrument Company, Collegeville, PA) and the measured temperature was checked
and recorded periodically during the course of the study.  Had the temperature of the refrigerator
exceeded the range of 2 °C to 6 °C at any point during the study, the standards would have been
moved to a different refrigerator; however, such temperature fluctuations were not observed.

Standards were placed in either amber glass ampoules (part number 176796, Wheaton Science
Products, Millville, NJ) that were flame-sealed or amber glass vials, closed with Teflon-lined
silicone septa screw caps (part number 5182-0556, Agilent Technologies, Santa Clara, CA).
                               Figure 4. Solvent Distillation
Ampoule Sealing

One-milliliter aliquots of the working standards were transferred to 2-mL, pre-scored, amber,
borosilicate  ampoules (Wheaton Science Products, as previously specified)  using  a  variable
volume (0.5  - 5.0 mL) pipettor tipped with a long Pasteur pipet (Model 831, VWR, Radnor, PA).
The ampoules were used as received from the vendor. The ampoules were loosely covered with a
septum while their headspace was flushed with argon.  The ampoules were then placed in liquid
nitrogen (to  freeze the solvent and prevent its evaporation) prior to flame sealing. Flame sealing
was done using an Ampulmatic® automated ampoule sealing device (Bioscience, Inc., Allentown,
PA), using a propane/oxygen flame. The procedures used to seal the ampoules were identical to
those used by LLNL to seal ampoules of ultra-dilute standards prior to sending them to the ERLN
laboratories.

-------
Instrumentation

GC/MS analyses were performed with an Agilent 5975C MS coupled with an Agilent 7890A GC
(both from Agilent Technologies,  Santa Clara, CA).  The GC/MS was tuned, as needed, with
perfluoro-tributylamine (PFTBA),  using the vendor's  algorithms.  Two nanograms decafluoro-
triphenylphosphine (DFTPP) were injected into the GC/MS after instrument  maintenance to
establish, by monitoring ion current response and mass spectrum, that the GC/MS was functioning
properly.

GC-flame photometric  detector (FPD)  analyses were performed with an Agilent 7890A GC
interfaced with a single P-channel FPD  (Agilent Technologies,  Santa Clara,  CA).   Prior to
analyses, the performance of the GC-FPD was tested with a standard containing malathion. This
standard has been used for several years  to test GC-FPD operation in our laboratory and has been
observed to have a shelf-life greater than  five years; a vendor of analytical standards has also noted
stability of five years for a mixed  pesticide standard containing 400 |ig/mL malathion in 90/10
(v/v) hexane/acetone (Cerilliant 2011).

For both GC/MS and GC-FPD analyses, the GC was equipped with an HP-5ms column, 30 m x
0.25 mm i.d. x 0.25 jim film thickness  (Agilent Technologies, Inc.). The GC oven was heated
using the following program: isothermal  for 1 min at 40 °C,  15 °C/min to 300 °C, and held
isothermal for 1 min, with the injector and detectors at 250 °C, and helium at 3 mL/min as carrier
gas.

An Aquamax Coulometric Karl Fischer  Titrator was used to measure water content in the stock
DCM solutions, dried DCM prior to standard preparation, and dried DCM stored in 40-mL VOA
vials over the course of the study. The Aquamax Coulometric  Karl  Fischer Titrator is unique
because of its excellent detection limits  for water; this  titrator can measure Ijig water in a 1-mL
sample. A single, previously unopened, 40-mL VOA was opened and analyzed at each sampling
time point. Additionally, all 40-mL VOA vials that had previously been opened and sampled at
prior time points were also re-opened and analyzed at each sampling time point.
Analytical Procedure

VX Analysis
Prior to analysis of the VX standards, at each sampling interval, the standards stored in flame-
sealed ampoules were transferred to screw cap vials. For both standards stored in flame-sealed
vials (now in screw cap vials) and originally stored in screw cap vials, a 50-|iL aliquot of the
standard was transferred to a 250-jiL vial insert and a 50-|iL aliquot of  10 |ig/mL malathion was
added as an internal standard.

-------
Individual standards were analyzed at the start of the experiment and subsequently as reported
below.
          •  t=0 analysis completed on 6 June 2012
          •  t=2 weeks analysis completed on 21 June 2012
          •  t=4 weeks analysis completed on 2 July 2012
          •  t=6 weeks analysis completed on 18 July 2012
          •  t=2 months analysis  completed on 7 August 2012
          •  t=3 months analysis  completed on 4 September 2012
          •  t=4 months analysis  completed on 2 October 2012
          •  t=5 months analysis  completed on 6 November 2012
          •  t=6 months analysis  completed on 4 December 2012
          •  t=9 months analysis  completed on 7 March 2013
          •  t=12 months analysis completed on 4 June 2013

For the analyses of the standard samples containing VX only, VX with 1 |ig/mL DIG, VX with 10
|ig/mL DIG, VX with 1 |ig/mL DCC, and VX with 10 |ig/mL DCC, triplicate ampoules/vials were
analyzed on each sampling day. Each analysis that was performed over the duration of the study
for standards in both sealed ampoules and screw cap vials was accomplished using a new, freshly-
opened ampoule or vial. Considering 11 time-points for sampling, that 3 replicate ampoules/vials
were analyzed at each timepoint, and that 5 different conditions were studied, 165 ampoules (plus
a few extra) were prepared and stored. Because the starting conditions at t=0 for the ampoules and
vials were the same, only 150 vials (plus a few extra) were prepared and stored. Note that the
sampling of the ampoules and vials was conducted in a  manner that would provide data on the
stability of the standards prior to their opening and prior to their continued use in a laboratory.

Water Analysis
Water concentrations were analyzed at the start of the experiment and subsequently as reported
below.
          •  t=0 analysis completed on 11 June 2012
          •  t=2 weeks analysis completed on 22 June 2012
          •  t=4 weeks analysis completed on 6 July 2012
          •  t=7 weeks analysis completed on 31 July 2012
          •  t=2 months analysis  completed on 13 August 2012
          •  t=3 months analysis  completed on 12 September 2012
          •  t=4 months analysis  completed on 9 October 2012
          •  t= 5 months analysis completed on 20 November 2012
          •  t= 6 months analysis completed on 13 December 2012
          •  t=9 months analysis  completed on 28 March 2013
          •  t=12 months analysis completed on 28 June 2013

For the DCM, water analysis was performed using both a new, freshly-opened vial and aliquots
that had been repeatedly opened and  closed during the course  of the study; this  practice was
followed to simulate how standards would be stored in vials and used by the CWA laboratories
(i.e.,  to understand if repeated opening and closing of the vials would affect the water content of
the DCM). Water analysis was performed in triplicate.

-------
Quantitation of Target Analytes

Each batch of samples was analyzed with a corresponding solvent blank, which consisted of dried
DCM from the same lot that was used to make the VX standards.  A calibration curve using VX
and malathion was run prior to analysis to assess GC/MS and GC-FPD performance. In addition,
at least every 9th sample analyzed and evaluated was a continuing calibration verification (CCV)
standard near the midpoint of the calibration range. The CCV response was required to be within
20 % of the  response  of the initial calibration for the data collected between CCV checks to be
considered valid. Quantitation was  performed  by the external  standard method  and  with
consideration of the practices  suggested in EPA Method 8000C (U.S. EPA, 2003).  A minimum
of five calibration levels were used for quantitation, covering a range from 0.5 |ig/mL to 10 |ig/mL
so that the analyte  concentrations would fall within  the calibration range. VX standards and
associated stabilizers to be measured were analyzed at 5 |ig/mL (assuming 100 % recovery of their
known t=0 concentration).  VX and  the stabilizers were quantified using quadratic regression
calibration curves.  R-Squared  values for all  calibration curves  were >0.99 and continuing
calibration standards showed that the standard responses remained within ±20 % of their expected
values during analyses.

The water content of the DCM samples was analyzed per the vendor instructions provided with
the Karl Fischer Titrator.
                             Results and Discussion

The concentrations of VX and the stabilizers were measured at various times to determine the
efficacy of the two stabilizers for maintaining the concentration of the 10-|ig/mL VX in DCM
during the course of the study.  DCM was selected as the solvent of interest because ultra-dilute
CWA standards are currently prepared and shipped to the ERLN laboratories in DCM. In contrast
to the previous study (U.S. EPA, 2013), attempts were made to ensure that dry DCM was used in
this study to minimize the potential for VX hydrolysis. While the concentration of water in the
DCM used  in the previous study was unknown (vendor specifications suggested an upper limit of
-200 |ig/mL, straight from the bottle), in this study, the DCM was dried by distillation before use
and the initial water concentration in DCM was kept as low as practical (25 jig/mL).  Standards
were stored in both sealed amber glass ampoules  and in amber glass vials with Teflon-lined
silicone septa screw caps.  The  sealed glass ampoules represent how the ultra-dilute CWA
standards are currently shipped to the ERLN laboratories and how the standards would be stored
prior to their use. Screw-capped vials represent the storage conditions of working solutions in use
by laboratories.

The initial concentration of VX in each standard was 10 |ig/mL. The initial concentrations of the
two stabilizers were 1 |ig/mL and 10 jig/mL.  The standards were diluted by a factor of two prior
to analysis  to ensure that the linear ranges of the GC/MS and GC-FPD were not exceeded.  The
results of the analyses are presented in Figures 5-9 as graphs of concentration versus time for each
component. The data presented in Figures 5-7 show no marked changes in VX concentrations as
a function of time under any of the conditions studied. The corresponding data for DIG and DCC
in Figures 8 and 9 likewise show no marked changes in stabilizer concentrations as a function of
time.

-------
                   VX Concentration GC/MS
                        No Stabilizer
VX Concentration GC-FPD
     No Stabilizer
la




E 10
a
1
1
e
S
g
u






i




1
i










\
T
f T
I '
1 .









-2 0
~n i
i







1





fit 	 | 	 !










1
i
1

i
i
I

2 4











I,,,,,,,,,,,, 	 „
I







I I I




	 i 	
if



" 	 '

i a



i
i








i





j


• Flame Sealed Ampoules
• Screw Cap Vials
13




E 10
a
a
e
o>
0
g
U
2$ c
> 3




n
1







-









tf













i 	 f 	 ;









1




i" 	 ^










•. 	






!


•
•
6 8 10 12 14 -20246
Time, months Time, months
                                                                                               10    12   14
 Figure 5. VX concentration in standards without stabilizer analyzed by (a) GC/MS and (b) GC-FPD.
  U

  g
      15
      10
                   VX Concentration GC/MS
                        DIC Stabilizer

|
t "
i





•

1i

1



i


i
i


i
i

• 1 ppm DIC Flame Sealed Ampoule
• 10 ppm DIC Flame Sealed Ampoule
* 1 ppm DIC Screw Cap Vial
» 10 ppm DIC Screw Cap Vial
                                       10
                                            12
                                                 14
                                                           |
                                                               15
                                                               10
                                                                 -2
VX Concentration GC-FPD
     DIC Stabilizer

1

ii

;
f



i
I
i
i i
'?!
i
!
|
I
i

i
i
b
i

• 1 ppm DIC Flame Sealed Ampoule
• 10 ppm DIC Flame Sealed Ampoule
* 1 ppm DIC Screw Cap Vial
T 10 ppm DIC Screw Cap Vial
                                                                                4     6     !

                                                                                 Time, months
                                                                                                10
                                                                                                     12
                                                                                                          14
                         Time, months


Figure 6. VX concentration in standards with DIC stabilizer analyzed by (a) GC/MS and (b) GC-FPD.
                                                                                                    10

-------
      15
                    VX Concentration GC/MS
                        DCC Stabilizer
   I
       10
1 1 1 [




T
H
1









' i 	 ¥ I 	
i?M

	 r 	




-»_~l
1
i




1
i

i
i
a

i



i


• 1 ppm DCC Flame Sealed Ampoule
• 10 ppm DCC Flame Sealed Ampoule
» 1 ppm DCC Screw Cap Vial
T 1 ppm DCC Screw Cap Vial
                                                               15
                VX Concentration GC-FPD
                     DCC Stabilizer
I
                                                               10

	 :


*


i


* 	 *
1 1


— t— i
I
A

i
T

i
i
i
i
|
r
r~~j
i . :
1
!
|
b
i
: ]
• 1 ppm DCC Flame Sealed Ampoule
• 10 ppm DCC Flame Sealed Ampoule
» 1 ppm DCC Screw Cap Vial
» 1 0 ppm DCC Screw Cap Vial
                                       10
                                            12
                         Time, months
                                                                                 4    6    (

                                                                                  Time, months
                                                                                                10
                                                                                                     12
Figure 7. VX concentration in standards with DCC stabilizer analyzed by (a) GC/MS and (b) GC-FPD.
                          15
                      I
                      u
                      u
                      5
                          10
                                         DIC Concentration GC/MS
• 1 ppm DIG Flame Sealed Ampoule
• 10 ppm DIG Flame Sealed Ampoule
+ 1 ppm DIG Screw Cap Vial
T 10 ppm DIG Screw Cap Vial
- 	 !-i 	 U 	 f 	
Plfl •
I I I '
f-'if f (
•
i
• i
i i '
i
i
i
i



•
1
1
!
i
\
                            -20     2     4     6     8     10    12    14

                                               Time, months
                                    Figure 8. DIC Concentration
                                                                                                    11

-------
                 DCC Concentration GC/MS
    15
I

a

73
u
u
10
      -2
T

1
1
i
1 ppm DCC Flame Sealed Ampoule
10 ppm DCC Flame Sealed Ampoul
1 ppm DCC Screw Cap Vial
10 ppm DCC Screw Cap Vial
* T
[ T* *
T |
I .
i
•
! 4
T
, ft '

i
i
-j


i
i
•
\


J
1


t
                       4     6    i


                        Time, months
                                       10
                                            12
                                                 14
            Figure 9. DCC Concentration
                                                                          12

-------
A program called "R" (R Core Team, 2012) was used to determine whether differences in VX
concentrations as a function of time could be discerned using statistical analyses.  Statistical
analyses were performed using the data collected by FPD.  While  data were collected by both
GC/MS and  GC-FPD, statistical  analyses were  performed using only the FPD data because
GC/MS measurements collected after the initial time point of the experiment appeared to be greater
in concentration than the initial measurements, suggesting issues with the GC/MS data collected
at the first time point only. As it is not possible to form VX under the conditions of the experiment,
it is possible that GC/MS column (e.g., active sites) and source conditions might have resulted in
a low initial measurement. Because it has been our experience that GC-FPD is a simpler and more
stable detector, data collected with GC-FPD were selected for statistical analyses.

Dunnett's test (Hsu, 1996) was  performed separately for each set of experimental  conditions (each
combination of stabilizer and container) to compare the VX concentrations measured at each time
point (i.e., t > 0) with the initial measured VX concentrations (t = 0).  The null hypothesis was that
the  average VX concentrations at the  later times are greater than or equal to the  initial  VX
concentration. The alternative hypothesis was that one or more average VX concentrations at a
later time  was less than the  initial  VX  concentration  (a  one-sided  test).  Results  of these
comparisons are shown in Table 1.

Although each set of experimental conditions was evaluated repeatedly over time, the vials or
ampoules from which samples were extracted were different at each time.  That is, the solution
analyzed at any given time point was taken from a different vial or ampoule than  every other time
point. Therefore, the measurements at each time point are statistically independent of those at other
time points (this would not have been the case if solution from each vial or ampoule had been
extracted at multiple time points).

At a significance level (a) of 0.01 [a conservative value of a = 0.01 was chosen over the commonly
used value  of a = 0.05 to compensate for the increased rate of statistical false positives resulting
from multiple applications  of Dunnett's test], statistically significant lower VX concentrations
were observed for VX stored in ampoules with no stabilizer, at three, five, and twelve months of
storage, and for VX stored in ampoules with 1 |ig/mL DCC (Table 1, "DCC-lo") at two weeks and
five and twelve months, and for VX stored in vials with 10 |ig/mL of DIG ("DIC-hi") at five and
twelve months.  At month twelve of the  study, seven of the ten different conditions tested showed
statistically significant decreases in VX concentration;  only VX in an ampoule with 10 |ig/mL DIG
("DIC-hi"), VX in a vial with 1 jig/mL DCC ("DCC-lo"), and VX in a vial with 10 |ig/mL DCC
("DCC-hi") did not show statistically significant decreases in concentration.
                                                                                      13

-------
Table 1. Significance levels (p values) for comparison of VX concentrations measured by GC/FPD at time t (months) and time 0; p<0.01 indicates
statistically significant concentration decrease.
Type
Ampoule
Ampoule
Ampoule
Ampoule
Ampoule
Vial
Vial
Vial
Vial
Vial
Stabilizer
NOST
DIC-lo
DIC-hi
DCC-lo
DCC-hi
NOST
DIC-lo
DIC-hi
DCC-lo
DCC-hi
to
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
t0.5-tO
0.35
0.27
0.44
O.01
0.20
0.96
0.90
0.09
0.58
0.67
ti-to
0.62
0.43
0.88
0.28
0.70
0.72
0.67
0.02
0.66
0.73
ti.5-to
1.0
0.99
0.98
1.0
1.0
1.0
1.0
0.99
1.0
1.0
t2-to
1.0
1.0
0.98
1.0
1.0
0.88
0.99
0.30
1.0
0.93
t3-to
0.01
0.88
1.0
0.98
1.0
0.91
1.0
0.95
1.0
0.99
t4-tO
0.84
1.0
0.89
0.80
1.0
0.96
0.95
0.40
0.93
0.87
ts-to
0.01
0.13
0.68
O.01
0.23
0.01
0.08
O.01
0.21
0.79
t6-to
1.0
0.95
0.96
1.0
1.0
0.73
1.0
0.31
0.92
0.84
t9-to
0.41
0.26
0.74
0.26
0.15
0.74
0.88
0.38
0.98
0.98
t!2-tO
0.01
0.01
0.45
O.01
O.01
O.01
O.01
O.01
0.25
0.92
Notes: "NOST"= no stabilizer, "DIC-lo" = 1 ug/mL of dicyclohexylcarbodiimide as stabilizer, "DIC-hi" = 10 ug/mL of dicyclohexylcarbodiimide as stabilizer, "DCC-lo"= 1
ug/mL dicyclohexylcarbodiimide as stabilizer, and "DCC-hi" = 10 ug/mL dicyclohexylcarbodiimide as stabilizer.
                                                                                                                                                 14

-------
Figures 10 and 11 plot VX concentrations as measured with GC-FPD versus time for all conditions
of VX standards stored in sealed ampoules and vials, respectively. While all data were collected
on the same day, the values representing each experimental condition are slightly offset to facilitate
comparison of VX concentrations.

Ultimately, it is desired to use the above data to inform decisions regarding recommendations
about how  long ERLN laboratories can store VX standards and how LLNL should best prepare
such standards for these laboratories.  When interpreting the above data, several assumptions were
made. First, statistical tests assume equality of all VX concentrations of specific conditions, until
otherwise indicated.  It has also been assumed that all aliquots of VX of the same conditions, or
treatment (e.g. storage container type, stabilizer type, or no stabilizer), will behave similarly and,
once begin to degrade, will degrade, continuously, at a constant rate.  It is expected that once an
indication of degradation is detected at a time point (as determined by  a p-value supporting the
rejection of the null  hypothesis), continued degradation at subsequent time points should be
observed. While several instances of statistically significant decreases in VX concentrations were
observed during the first six months of the study (t=0.5 months for ampoule  with DCC-lo; t=3
months for ampoule with no stabilizer; t=5 months for ampoules with no stabilizer and DCC-lo,
and vials with no stabilizer and DIG-hi), subsequent analyses at 6 months and 9 months showed
no statistically significant decreases in VX concentrations (i.e. no trends in continued decreases in
VX concentrations were  observed).  Consequently, the standards were considered stable for the
first nine months of the study. Further testing is needed to confirm VX stability at nine months
and investigate the random instances of decreased VX concentration noted above.

Because several time points prior to 9 months showed statistically significant decreases in VX
concentrations, it is possible that  "bad  ampoules/vials"  may  sometimes  be encountered;
however,the reason  for this is unclear.  Possiblities  include  reaction of  VX with  water
contamination in the vials (e.g. water introduced during any procedure  where the VX ampoules
were  being handled), reaction of VX  with impurities  from either the  stabilizers or from VX
synthesis by products, or  some other process not completely understood.  Although  several
samples exhibited statistically significant decreases in VX concentration, these concentrations
were  still within -20% of their initial concentration.  By month 12,  because the majority of
conditions  (7 out of 10) showed statistically significant decreases in concentration, it cannot be
concluded with certainty that the standards are stable for 12 months. Further testing is necessary,
including repeating the holding time study, using the same conditions, to determine the stability
for VX under all tested conditions, but was outside the scope of this study. There were no data to
suggest that DIG or DCC stabilizers prevented VX degradation under the conditions of this study.
During this study, the amount of atmospheric water that a standard might adsorb during use was
considered.  Figure 12 shows a plot of water concentration in DCM versus the number of times a
vial was opened. One previously-unopened 40-mL vial was opened at each time point, along with
other vials that had been opened at preceding time points. Only a single vial was opened 10 times
during the study, and the error bars associated with this data point represent the standard deviation
of three independent, water measurements that were made for the DCM in this vial.   Ten vials
were opened once, with the corresponding data point in Figure 12  reflecting the deviations of
triplicate measurements for water concentrations in each of the 10 vials.  Figure 12 indicates that,
as vials are opened  and closed, the  solvent DCM absorbs water from  the environment.  It is
important to note that the vials were opened and closed multiple times over the course of the study.
                                                                                       15

-------
In contrast, the VX standards were opened only once at the appropriate analytical time point (i.e.,
at any given time point, the analyzed solution was taken from a different vial or ampoule than the
vial or ampoule at every other time point) and were not exposed to water from the environment.
At the beginning of the study, the water content of the DCM was approximately 27 jig/mL; by the
end of the study,  the water content of the DCM that had been opened ten times was 94  |ig/mL.
Vendor analyses claim that the water content of DCM, fresh from the bottle, is approximately 200
|ig/mL. Note that the water content of the DCM observed at the end of the study remained below
200 jig/mL.  In a previous study, we observed that some VX standards made using DCM fresh
from the bottle were unstable under
 c
 I
 n
 O
     to -1
+ MOST
* DIC-lo
X DIC-hi
+ DCC-lo
X DCC-hi
\
-
•»
X
X
*
«
*
H « £ $
* S ; *
. ? *. j
0    1 in   2m
                            3m   4m
Sm    6m

  Elapsed time
9m               12m
                                                                        2013-06-12 09]M:27
       Notes: Grey line indicates average VX concentration at t=0; "NOST"= no stabilizer, "DIC-lo" = 1 ug/mL
       of dicyclohexylcarbodiimide as stabilizer, "DIC-hi" = 10 ug/mL of dicyclohexylcarbodiimide as stabilizer,
       "DCC-lo"= 1 ng/mL dicyclohexylcarbodiimide as stabilizer, and "DCC-hi" = 10 ug/mL
       dicyclohexylcarbodiimide as stabilizer.
                   Figure 10. VX concentrations in sealed ampoules vs. time.
                                                                                        16

-------
1—
c
O
00
Q
«J -
+ MOST
« DIC-lo x
x DIC-hi
+ DCC-lo "
x DCC-hi ^
*" . X *
•4fi x
+** ^ \ ** J* ^ x B
/^5*fr : !f : S ¥
* * £ * 1*
*
* «
i i i i i i i i i i i
0 1m 2m 3m 4m 5m 6m 9m 12m
Elapsed time
Notes: Grey line indicates average VX concentration at t=0; "NOST"= no stabilizer, "DIC-lo" = 1 ug/mL
of dicyclohexylcarbodiimide as stabilizer, "DIC-hi" = 10 ug/mL of dicyclohexylcarbodiimide as stabilizer,
"DCC-lo"= 1 ug/mL dicyclohexylcarbodiimide as stabilizer, and "DCC-hi" = 1 ug/mL
dicyclohexylcarbodiimide as stabilizer.
                    Figure 11. VX concentrations in vials vs. time.
                                                                                            17

-------
              CL

              CL
              Oj

              u
                  100
                  30
                   60
              <^   40
              tu


              I
                  20
-2
                                  DCM Water Concentration

                                         12 Months

          t	f
2468



  Number of times opened
                                                              10
12
Figure 12. Water concentration in DCM stored in screw capped vials as compared to the number of

                 times the vials were opened over the 12 month study period.
                                                                                     18

-------
certain conditions, and we now speculate that this instability might have been caused by hydrolysis
of VX initiated by the introduction of water during preparation or use of the standards. However,
we can only speculate that water content above the 200 |ig/mL threshold may cause VX hydrolysis;
note that some support for this idea is suggested by the fact that we observed that VX in sealed
ampoules containing DCM was stable for 12 months, while VX in hexane,  which could have
contained as much as 500 |ig/mL water, stored in sealed ampoules, was stable for only 3  months
(U.S. EPA, 2013).  The question of at what  water concentration in DCM adversely affects VX
concentration was beyond the scope of this study.  However, the data suggest that, when in use,
vials of standards should be left open for as short a period as possible.


                                     Conclusions

VX concentrations were measured at various time points over the course of a year towards the goal
of determining the efficacy of two stabilizers — DIG  and DCC — for  10 |ig/mL VX in DCM
compared to a VX solution without any added stabilizer. Using the data obtained, some guidance
may be given about supplying the ERLN with VX standards.

With regards to preparing standards, the data did not suggest that the use of either DIG or DCC as
a stabilizer was  warranted; thus, the current practice of supplying 10-|ig/mL VX standards in
DCM, without stabilizer, to the ERLN laboratories should be continued. The distillation step used
to dry the DCM prior to making the VX standards may help preserve the VX (i.e., prevent its
hydrolysis, the only plausible mechanism for VX degradation in DCM). In the previous study, the
water content of the DCM and hexane used  to make VX standards was not controlled,  and the
same VX standard vial was opened at each sampling interval, repeatedly exposing the VX standard
to the environment  (note that in the previous study,  only  the vials, and  not the ampoules, were
repeatedly opened). In this  study, a new ampoule or vial  was opened at each sampling  interval
preventing exposure to the environment over the course of the study.  While we cannot conclude
that drying of DCM by distillation (residual water concentration of-25 |ig/mL) is better than using
DCM directly from the bottle (residual water concentration of-200 |ig/mL), as a best practice, we
recommend that the driest solvents  possible should  be  used  when preparing  VX standards.
Conducting laboratory  manipulations with conscious thought about minimizing the potential for
the analyte to be exposed to water appears to be a prudent practice.

With regards to packaging standards, statistical analysis did not  show a clear preference between
the use of sealed ampoules and screw-capped vials.  However, the only statistically significant
degradation observed before the five-month time point (t=0.5 months with DCC-lo and t=3  months
with no stabilizer) was in a sealed ampoule.  Because liquid nitrogen is used to cool the DCM
during the flame-sealing process, it may be possible  to unintentionally, and randomly, introduce
water into the standard during ampoulation, which might contribute to VX degradation.  Based on
the complexity and potential  complications (soot formation, overpressure with purge gas, etc.)
with flame sealing, we recommend storing and shipping standards in screw-capped vials.

Based on the statistical anaylsis of the holding time data points, no continuous trend, with respect
toVX degradation, was observed at Month 9 of the study, under any of the storage conditions (i.e.,
consecutive data points evaluated at different holding times exhibiting a statistically significant
difference).    Therefore, VX standards of 10 |ig/mL in DCM may not  degrade at a significant

                                                                                      19

-------
levels for at least 9 months. However, some statistically significant decreases in VX were observed
at random time points prior to 9 months making it is possible for a lab to occasionally receive a
standard that will not be at its expected concentration.  Thus, it is strongly recommended to check
(by analysis) the concentrations of such standards prior to use. If an ERLN laboratory receives a
vial/ampoule of standard that appears to provide a lower than expected response for VX, that
laboratory may choose to open and use another vial of standard.

Further testing is necessary, including multiple holding time  studies using the same conditions,
to determine a more accurate depection of the stability for VX under all tested conditions,
including a longer holding time. Multiple evaluations of VX under the exact storage condtions
provided in this document will provide a more detailed description of what may be occurring,
with respect to degradation. Given the variability of some of the data, a follow-up study using a
different analytical technique, such as liquid chromatography/mass spectrometry (Love, 2004),
which would be able to detect both VX and its hydrolysis product, may be desirable.
                                                                                      20

-------
                                       References

Black, R. M., Muir, B. (2003) Derivatisation reactions in the chromatographic analysis  of chemical
warfare agents and their degradation products. J. Chromatogr. A, 1000 (1-2), 253-281.

Buckles  L.  C.,  Lewis S.  M.  and  Lewis  F.  E.  (1977)  S-(2-diisopropylamino-ethyl)  O-ethyl
methylphosphonothiolate stabilized with soluble carbodiimides. United States Patent 4,012,464.

Cerilliant, (2011)  Certificate of Analysis for Pesticide Mix-11  (Catalog Number ERP-105, Solution Lot
Number ER032911-01).

Hsu, J. C. (1996) Multiple Comparisons, Theory and Methods (Chapter 3), Chapman & Hall, NY (ISBN 0
41298281 1).

Li, J. J., Limberakis, C. and Pflum, D. A. (2007) Modern Organic Synthesis in the Laboratory (Chapter 1),
Oxford University Press, NY (ISBN13: 9780195187991).

Love, A.H., Vance, A.  L., Reynolds,  J. G., Davisson,  M. L. (2004) Investigating the affinities and
persistence of VXnerve agent in environmental matrices, Chemosphere  57 (10), 1257-1264.

Munro, N. B., Talmage, S. S.,  Griffin, G. D., Waters, L. C., Watson,  A. P.,  King, J. F., Hauschild, V.
(1999) The sources, fate, and toxicity of chemical warfare agent degradation products.  Environ. Health
Perspect. 107 (12), 933-974.

Pardasani, D., Purohit, A., Mazumder, A.,  Dubey, D. K. (2010)  Gas chromatography-mass spectrometric
analysis of trimethylsilyl derivatives of toxic hydrolyzed products of nerve agent VX and its analogues for
verification of Chemical Weapons Convention. Anal. Methods 2(6), 661-667.

R Core Team. (2012) R: A language and environment for statistical computing. R Foundation for Statistical
Computing, Vienna, Austria. ISBN 3-900051-07-0. Accessed September 10, 2014, URL http://www.R-
project.org/.

Rohrbaugh  D.  K.   (1998)  Characterization  of equimolar VX-water reaction product by  gas
chromatography-mass spectrometry. J. Chromatogr. 809, 131-139.

Rosenblatt, D. H., Small, M. J., Kimmell,  T. A.,  Anderson, A.  W. (1996) Background Chemistry for
Chemical Warfare Agents and Decontamination Processes in Support ofDelisting Waste Streams at the
U.S. Army Dugway Proving Ground, Utah, ANL/EAD/TM-56.

U.S.  Environmental  Protection Agency.  (2003) Method 8000C:  Determinative Chromatographic
Separations. Revision  3. Washington DC: U.S. Environmental Protection Agency.

U.S. Environmental  Protection Agency. (2013) Stability Study for Ultra-Dilute Chemical Warfare Agent
Standards. EPA 600/R-13/044.

Yang Y.-C. (1999) Chemical detoxification of nerve agent VX. Ace. Chem. Res. 32, 109-115.

Yang Y.-C., Szafraniec  L. L., Beaudry W. T.,  Rohrbaugh D. K., Procell L. R, Samuel J.  B. (1996)
Autocatalytic hydrolysis ofV-type nerve agents. J. Org. Chem. 61, 8407-8413.
                                                                                           21

-------
United States
Environmental Protection
Agency
PRESORTED STANDARD
 POSTAGE & FEES PAID
         EPA
   PERMIT NO. G-35
Office of Research and Development (8101R)
Washington, DC 20460

Official Business
Penalty for Private Use
$300

-------