EPA/625/R-96/010b
       Compendium of Methods
     for the Determination of Toxic
          Organic Compounds
             in Ambient Air

            Second Edition
      Compendium Method TO-17

   Determination of Volatile Organic
Compounds in Ambient Air Using Active
     Sampling Onto Sorbent Tubes
       Center for Environmental Research Information
          Office of Research and Development
          U.S. Environmental Protection Agency
              Cincinnati, OH 45268

                January 1999

-------
                                       Method TO-17
                                     Acknowledgements

This Method was prepared for publication in the Compendium of Methods for the Determination of Toxic
Organic Compounds in Ambient Air, Second Edition (EPA/625/R-96/010b), which was prepared under
Contract No. 68-C3-0315, WA No. 3-10, by Midwest Research Institute (MRI), as a subcontractor to
Eastern Research Group, Inc. (ERG), and under the sponsorship of the U. S. Environmental Protection
Agency (EPA). Justice A. Manning, John O. Burckle, and Scott Hedges, Center for Environmental Research
Information (CERI), and Frank F. McElroy, National Exposure Research Laboratory (NERL), all in the EPA
Office of Research and Development, were responsible for overseeing the preparation of this method.
Additional support was provided by other members of the Compendia Workgroup, which include:

         John O. Burckle, U.S. EPA, ORD, Cincinnati, OH
         James L. Cheney, Corps of Engineers, Omaha, NB
         Michael Davis, U.S. EPA, Region 7, KC, KS
         Joseph B. Elkins Jr., U.S. EPA, OAQPS, RTP, NC
         Robert G. Lewis, U. S. EPA, NERL, RTP, NC
         Justice A. Manning, U.S. EPA, ORD, Cincinnati, OH
    •    William A. McClenny, U.S. EPA, NERL, RTP, NC
         Frank F. McElroy, U.S. EPA, NERL, RTP, NC
         Heidi Schultz, ERG, Lexington, MA
    •    William T.  "Jerry" Winberry, Jr., EnviroTech Solutions, Gary, NC

This Method is the result of the efforts of many individuals. Gratitude goes to each person involved in the
preparation and review of this methodology.

Author(s)
    • Elizabeth A. Woolfenden, Perkin Elmer Corp., Wilton, CT
    • William A. McClenny, U.S. EPA, NERL, RTP, NC

Peer Reviewers
    • Joan T. Bursey, ERG, Morrisville, NC
    • Martin Harper, SKC Inc., Eighty-Four, PA
    • Irene D. DeGraff, Supelco, Inc., Bellefonte, PA
    • Joseph E. Bumgarner, U. S. EPA, NERL, RTP, NC
    • Lauren Drees, U.S. EPA, NRMRL, Cincinnati, OH

Finally, recognition is given to Frances Beyer, Lynn Kaufman, Debbie Bond, Cathy Whitaker, and Kathy
Johnson of Midwest Research Institute's Administrative Services  staff whose dedication and persistence
during the development of this manuscript has enabled it's production.
                                        DISCLAIMER

This Compendium has been subjected to the Agency's peer and administrative review, and it has
been approved for publication as an EPA document. Mention of trade names or commercial
products does not constitute endorsement or recommendation for use.

-------
                                       METHOD TO-17

                  Determination of Volatile Organic Compounds in Ambient Air
                           Using Active Sampling Onto Sorbent Tubes

                                    TABLE OF CONTENTS

                                                                                           Page


1.   Scope  	      17-1

2.   Summary of Method  	      17-2

3.   Significance 	      17-3

4.   Applicable Documents	      17-4
    4.1 ASTM Standards	      17-4
    4.2 EPA Documents	      17-4
    4.3 Other Documents	      17-4

5.   Definitions  	      17-5

6.   Overview of Methodology	      17-6
    6.1 Selection of Tube and Sorbent	      17-7
    6.2 Conditioning the Tube	      17-7
    6.3 Sampling Apparatus  	      17-7
    6.4 Sampling Rates  	      17-7
    6.5 Preparing for Sample Collection	      17-8
    6.6 Set the Flow Rates	      17-8
    6.7 Sample  and Recheck Flow Rates	      17-8
    6.8 Reseal the Tubes  	      17-8
    6.9 Selection of Thermal Desorption System  	      17-8
    6.10   Dry Purge the Tubes and Prepare for Thermal Desorption  	      17-9
    6.11    Check for System Integrity 	      17-9
    6.12   Repurge of Tube on the Thermal Desorber/Addition of Internal Standard  	      17-9
    6.13    Thermally Desorb the Packing  	      17-9
    6.14   Trap Desorption and GC/MS Analysis	      17-9
    6.15    Restoring the Tubes and Determine Compliance with Performance Standards	      17-9
    6.16   Record and Store Data	     17-10

7.   Interferences and Limitations	     17-10
    7.1 Interference from Sorbent Artifacts	     17-10
    7.2 Minimizing Interference from Water	     17-11
    7.3 Atmospheric Pollutants not Suitable for Analysis by this Method	     17-12
    7.4 Detection Limits and Maximum Quantifiable Concentrations of Air Pollutants	     17-12
    7.5 Suitable Atmospheric Conditions  	     17-12
                                              in

-------
                              TABLE OF CONTENTS (continued)

                                                                                           Page

8.   Apparatus Selection and Preparation	      17-13
    8.1 Sample Collection  	      17-13
    8.2 Apparatus	      17-14
    8.3 Tube Conditioning Apparatus	      17-15

9.   Reagents and Materials 	      17-16
    9.1 Sorbent Selection Guidelines	      17-16
    9.2 Gas Phase Standards	      17-17
    9.3 Liquid Standards  	      17-17
    9.4 Gas Phase Internal Standards  	      17-19
    9.5 Commercial, Preloaded Standard Tubes	      17-19
    9.6 Carrier Gases	      17-19

10.  Guidance on Sampling and Related Procedures 	      17-20
    10.1   Packing Sorbent Tubes  	      17-20
    10.2   Conditioning and Storage of Blank Sorbent Tubes 	      17-21
    10.3   Record Keeping Procedures for Sorbent Tubes  	      17-21
    10.4   Pump Calibration and Tube Connection	      17-22
    10.5   Locating and Protecting the Sample Tube  	      17-22
    10.6   Selection of Pump Flow Rates and Air Sample Volumes	      17-22
    10.7   Sampling Procedure Verification - Use of Blanks, Distributed Volume Pairs,
           BackUp Tubes, and Distributed Volume Sets  	      17-23
    10.8   Determining and Validating Safe Sampling Volumes (SSV)	      17-24
    10.9   Resealing Sorbent Tubes After Sample Collection	      17-25
    10.10  Sample Storage 	      17-25

11.  Analytical Procedure  	      17-25
    11.1   Preparation for Sample Analysis	      17-25
    11.2   Predesorption System Checks and Procedures	      17-25
    11.3   Analytical  Procedure	      17-26

12.  Calibration of Response	      17-27

13.  Quality Assurance  	      17-27
    13.1   Validating the Sample Collection Procedure	      17-27
    13.2   Performance Criteria for the Monitoring Pump  	      17-28

14.  Performance Criteria for the Solid Adsorbent Sampling of Ambient Air	      17-28
    14.1   Introduction	      17-28
    14.2   Method Detection Limit 	      17-28
    14.3   Analytical  Precision of Duplicate Pairs	      17-29
    14.4   Precision for the Distributed Volume Pair  	      17-29
    14.5   Audit Accuracy 	      17-29

15.  References 	      17-30
                                               IV

-------
                                        METHOD TO-17

                Determination of Volatile Organic Compounds in Ambient Air Using
                               Active Sampling Onto Sorbent Tubes
1. Scope
1.1  This document describes a sorbent tube/thermal desorption/gas chromatographic-based monitoring method
for volatile organic compounds (VOCs) in ambient air at 0.5 to 25 parts per billion (ppbv) concentration levels.
Performance criteria are provided  as part of the method in Section 14.  EPA has previously published
Compendium Method TO-1 describing the use of the porous polymer Tenax® GC for sampling nonpolar VOCs
and Compendium Method TO-2 describing the use of carbon molecular sieve for highly volatile, nonpolar
organics (1).  Since these methods were developed, a new generation of thermal desorption systems as well as
new types of solid adsorbents have become available commercially.  These sorbents are used singly or in
multisorbent packings. Tubes with more than one sorbent, packed in order of increasing sorbent strength are used
to facilitate quantitative retention and desorption of VOCs over a wide volatility range. The higher molecular
weight compounds are retained on the front, least retentive sorbent; the more volatile compounds are retained
farther into the packing on a stronger adsorbent. The higher molecular weight compounds never encounter the
stronger adsorbents, thereby improving the efficiency of the thermal desorption process.

1.2 A large amount of data on solid adsorbents is available through the efforts of the  Health and Safety
Laboratory,  Health and Safety Executive (HSE), Sheffield, United Kingdon (UK). This group has provided
written methods for use of solid adsorbent packings in monitoring workplace air. Some of their documents on
the subject are referenced in Section 2.2.  Also, a table of information on safe sampling volumes from their
research is provided in Appendix 1.

1.3 EPA has developed data on the use of solid sorbents in multisorbent tubes for concentration of VOCs from
the ambient air as part of its program for methods development of automated  gas chromatographs.  The
experiments required to validate the use of these sorbent traps include capture and release efficiency studies for
given sampling volumes.  These studies establish the validity of using solid adsorbents for target sets of VOCs
with minimal (at most one hour) storage time.  Although questions related to handling, transport and storage of
samples between the times of sampling and analysis are not addressed, these studies provide information on safe
sampling volumes. Appendix 2 delineates the results of sampling a mixture of humidified zero air and the target
VOCs specified in the Compendium Method TO-14 (2) using a specific multisorbent.

1.4 An EPA workshop was convened in November of 1995 to determine if a consensus could be reached on the
use of solid sorbent tubes for ambient air analysis.  The draft method available at the workshop has evolved
through several reviews and modifications into the current document. The method is  supported by data reported
in the scientific literature as cited in the text,  and by recent experimental tests performed as a consequence of the
workshop (see Table 1).

1.5  The  analytical approach using gas  chromatography/mass  spectroscopy (GC/MS) is identical to that
mentioned in Compendium Method TO-15 and, as noted later, is adapted for this method once the sample has
been thermally desorbed from the adsorption tube onto the focusing trap of the analytical system.
January 1999        Compendium of Methods for Toxic Organic Air Pollutants            Page 17-1

-------
Method TO-17	VOCs

1.6  Performance criteria are given in Section 14 to allow acceptance of data obtained with any of the many
variations of sampling and analytical approaches.
2. Summary of Method

2.1  The monitoring procedure involves pulling a volume of air through a sorbent packing to collect VOCs
followed by a thermal desorption-capillary GC/MS analytical procedure.

2.2 Conventional detectors are considered alternatives for analysis subject to the performance criteria listed in
Section 14 but are not covered specifically in this method text.

2.3 Key steps of this method are listed below.

    2.3.1  Selection of a sorbent or sorbent mix tailored for a target compound list, data quality objectives and
sampling environment.
    2.3.2  Screening the sampling location for VOCs by taking single tube samples to allow estimates of the
nature and amount of sample gases.
    2.3.3  Initial sampling sequences with two tubes at nominally  1  and  4 liter total sample volumes (or
appropriate proportional scaling of these volumes to fit the target list and monitoring objectives).
    2.3.4  Analysis of the samples and comparison to performance criteria.
    2.3.5  Acceptance or rejection of the data.
    2.3.6 If rejection, then review of the experimental arrangement including repeat analysis or repeat analysis
with backup tubes and/or other QC features.

[Note:  EPA requires the use  of distributed volume pairs (see Section 14.4) for monitoring to insure high
quality data.  However, in situations where acceptable data have been routinely obtained through use of
distributed volume pairs and the ambient air is considered well characterized, cost considerations may
warrant single tube sampling.  Any attendant risk to data quality objectives  is the responsibility of the
project's decision maker.]

2.4 Key steps in sample analysis  are listed below.

    2.4.1 Dry purge of the sorbent tube with dry, inert gas before analysis to remove water vapor and air.  The
sorbent tube can be held at temperatures above ambient for the dry purge.
    2.4.2  Thermal desorption of the sorbent tube (primary desorption).
    2.4.3  Analyte refocusing on a secondary trap.
    2.4.4  Rapid desorption of the trap  and injection/transfer of target analytes into the gas chromatograph
(secondary desorption).
    2.4.5  Separation of compounds by high resolution capillary gas chromatography (GC).
    2.4.6  Measurement by mass  spectrometry (MS) or conventional GC detectors (only the MS approach is
explicitly referred to in  Compendium Method TO-17; an FID/ECD detector combination or other GC detector
can be used if Section 14 criteria are met.  However, no explicit QA guidelines are given here for those
alternatives).
Page 17-2            Compendium of Methods for Toxic Organic Air Pollutants        January 1999

-------
VOCs	Method TO-17

2.5 The target compound list (TCL) is the same as listed in Compendium Method TO-15 (i.e., subsets of the 97
VOCs listed as hazardous pollutants in Title III of the Clean Air Act Amendments of 1990).  Only a portion of
these compounds has been monitored by the use of solid adsorbents. This method provides performance criteria
to demonstrate acceptable performance of the method (or modifications of the method) for monitoring a given
compound or set of compounds.
3. Significance

3.1 This method is an alternative to the canister-based sampling and analysis methods that are presented in
Compendium Methods TO-14 and TO-15 and to the previous sorbent-based methods that were formalized as
Compendium Methods TO-1 and TO-2. All of these methods are of the type that include sampling at one
location, storage and transport of the sample, and analysis at another, typically more favorable site.

3.2 The collection of VOCs in ambient air samples by passage through solid sorbent packings is generally
recognized to have a number of advantages for monitoring. These include the following:

   • The small size and light weight of the sorbent packing and attendant equipment.

   • The placement of the sorbent packing as the first element (with the possible exception of a filter or
     chemical scrubber for ozone) in the sampling train so as to reduce the possibility of contamination from
     upstream elements.

   • The availability of a large selection of sorbents to match the target set of compounds including polar VOC.

   • The commercial availability of thermal desorption systems to release the sample from the sorbent and into
     the analytical system.

   • The possibility of water management using a combination of hydrophobic sorbents (to cause water
     breakthrough while sampling); dry gas purge of water from the sorbent after sampling; and splitting of the
     sample during analysis.

   • The large amount of literature on the use of sorbent sampling and thermal desorption for monitoring of
     workplace air, particularly the literature from the Health and Safety Executive in the United Kingdom.

3.3 Accurate risk assessment of human and ecological exposure to toxic VOCs is an important goal of the U.
S. Environmental Protection Agency (EPA) with increased emphasis on their role as endocrine disrupters.
Accurate data is fundamental to reaching this goal.  The portability and small size of typical sampling packages
for sorbent-based sampling and the wide range of sorbent choices make this monitoring approach appealing for
special monitoring studies of human exposure to toxic gases and to use in network monitoring to establish
prevalence and trends of toxic gases. Microenvironmental and human subject studies are typical of applications
for Compendium Method TO-17.

3.4  Sorbent-based monitoring can be combined with canister-based monitoring methods, on-site autoGC
systems, open path instrumentation, and  other specialized point monitoring instruments to address most
monitoring needs for volatile organic gases. More than one of these approaches can be used simultaneously as
a means to check and insure the quality of the data being produced.
January 1999        Compendium of Methods for Toxic Organic Air Pollutants            Page 17-3

-------
Method TO-17                                                                          VOCs
3.5 In the form specified in Compendium Method TO-17, sorbent sampling incorporates the distributed volume
pair approach that provides inherently defensible data to counter questions of sample integrity, operator
performance, equipment malfunction during sampling, and any other characteristic of sample collection that is
not linear with sampling volume.

3.6 In keeping with the consensus of EPA scientists and science advisors, the method is performance-based such
that performance criteria are provided.  Any modification of the sorbent approach to monitoring for VOCs can
be used provided these criteria are met.
4.  Applicable Documents

4.1 ASTM Standards

   • Method D1356 Definition of Terms Relating to Atmospheric Sampling and Analysis
   • Method E260 Recommended Practice for General Gas Chromatography
   • Method E355 Practice for Gas Chromatography Terms and Relationships

4.2 EPA Documents

   • Technical Assistance Document for Sampling and Analysis Toxic Organic Compounds in Ambient Air,
     U. S. Environmental Protection Agency, EPA-600/4-83-027, June 1983.
   • Quality Assurance Handbook for Air Pollution Measurement Systems, U.  S.  Environmental Protection
     Agency, EPA-600/R-94-038b, May 1994.
   • Compendium of Methods for the Determination of Toxic Organic Compounds in Ambient Air: Methods
     TO-l  andTO-2, U. S. Environmental Protection Agency, EPA 600/4-84-041, April 1984.
   • Compendium of Methods for the Determination of Toxic Organic Compounds in Ambient Air: Method
     TO-l4, Second Supplement, U. S. Environmental Protection Agency, EPA 600/4-89-018, March 1989.
   • Compendium of Methods for the Determination of Toxic Organic Compounds in Ambient Air: Method
     TO-15, U.  S. Environmental Protection Agency, EPA 625/R-96-010b, January 1997.

4.3 Other Documents

   • MDHS 3   -   Generation of Test Atmospheres of Organic Vapors by the Syringe Injection Technique,
                  Methods for the Determination of Hazardous Substances (MDHS), Health and Safety
                   Laboratory, Health and Safety Executive, Sheffield, UK.
   • MDHS 4   -   Generation of Test Atmospheres  of Organic Vapors by the Permeation Tube Method,
                  Methods for the Determination of Hazardous Substances (MDHS), Health and Safety
                   Laboratory, Health and Safety Executive, Sheffield, UK.
   • MDHS 72  -   Volatile Organic Compounds  in Air, Methods for the Determination of Hazardous
                   Substances  (MDHS), Health  and Safety Laboratory, Health and Safety  Executive,
                   Sheffield, UK.
   • TAD       -   Technical Assistance Document (TAD) on the Use of Solid Sorbent-based Systems for
                  Ambient Air Monitoring, Perkin Elmer Corp., 50 Danbury Rd., Wilton, CT 06897, USA.
Page 17-4           Compendium of Methods for Toxic Organic Air Pollutants        January 1999

-------
VOCs                                                                             Method TO-17
5. Definitions

[Note: Definitions used in this document and any user-prepared Standard Operating Procedures (SOPs)
should be consistent with those used in ASTMD1356.  All abbreviations and symbols are defined within this
document at the point of first use.]

5.1 Thermal Desorption-the use of heat and a flow of inert (carrier) gas to extract volatiles from a solid or
liquid matrix directly into the carrier gas and transfer them to downstream system elements such as the analytical
column of a GC. No solvent is required.

5.2 Two-stage Thermal Desorption-the process of thermally desorbing analytes from a solid or liquid matrix,
reconcentrating them on a focusing tube and then rapidly heating the tube to ?inject" the concentrated compounds
into the GC system in a narrow band of vapor compatible with high resolution capillary gas chromatography.

5.3 Sorbent Tube (Also referred to as 'tube' and 'sample tube')-stainless steel, glass or glass lined (or fused
silica lined) stainless steel tube, typically 1/4 inch (6 mm) O.D. and of various lengths, with the central portion
packed with greater than 200 mg of solid adsorbent material, depending on density and packing bed length. Used
to concentrate VOCs from air.

5.4 Focusing Tube-narrow (typically <3mm I.D.) tube containing a small bed of sorbent, which is maintained
near or below ambient temperature and used to refocus analytes thermally desorbed from the sorbent tube. Once
all the VOCs have been transferred from the sorbent tube to the focusing tube, the focusing tube is heated very
rapidly to transfer the analytes into the capillary GC analytical column in a narrow band of vapor.

5.5 Cryogen (Also referred to as 'cryogenic fluid')-typically liquid nitrogen, liquid argon, or liquid carbon
dioxide.  In the present context, cryogens are used in some thermal desorption systems to cool the focusing tube.

5.6 High Resolution Capillary Column Chromatography-conventionally describes fused silica capillary
columns with an internal diameter of 320 um or below and with a stationary phase film thickness of 5 um or less.

5.7 Breakthrough Volume (BV)-volume of air containing a constant concentration of analyte which may be
passed through a sorbent tube before a detectable level (typically 5%) of the analyte concentration elutes from
the nonsampling end.  Alternatively, the volume sampled when the amount of analyte collected in a back-up
sorbent tube reaches a certain percentage (typically 5%) of the total amount collected by both sorbent tubes.
These methods do not give identical results. For purposes in the document the former definition will be used.

5.8 Retention Volume (RV)-the volume of carrier gas required to move an analyte vapor plug through the short
packed column which is the sorbent tube.  The volume is determined by measuring the carrier gas volume
necessary to elute the vapor plug through the tube, normally measured at the peak response as the plug exits the
tube.  The retention volume of methane is subtracted to account for dead volume in the tube.
January 1999        Compendium of Methods for Toxic Organic Air Pollutants            Page 17-5

-------
Method TO-17	VOCs

5.9 Safe Sampling Volume (SSV)-usually calculated by halving the retention volume (indirect method) or
taking two-thirds of the breakthrough volume (direct method), although these two approaches do not necessarily
give identical results.  The latter definition is used in this document.

5.10 Sorbent Strength—term used to describe the affinity of sorbents for VOC analytes. A stronger sorbent
is one which offers greater safe sampling volumes for most/all VOC analytes relative to another, weaker sorbent.
Generally speaking, sorbent strength is related to surface area, though there are exceptions to this. The SSVs of
most, if not all, VOCs will be greater on a sorbent with surface area ?10n" than on one with a surface area of ?n".
As a general rule, sorbents are described as ?weak" if their surface area is less than  50 m2g"1 (includes Tenax®,
Carbopack™/trap C, and Anasorb® GCB2), Tmedium strength" if the surface area is in the range 100-500 m2g"1
(includes Carbopack™/trap B, Anasorb® GCBI and all the Porapaks and Chromosorbs listed in Tables 1 and
2) and?strong"ifthe surface area is around 1000 m2g"1 (includes Spherocarb®, Carbosieve™ S-III, Carboxen™
1000, and Anasorb® CMS series sorbents.)

5.11 Total Ion Chromatogram (TlC)-chromatogram produced from a mass spectrometer detector operating
in full scan mode.

5.12 MS-SCAN-mode of operation of a GC mass  spectrometer detector such that all mass ions over a given
mass range are swept over a given period of time.

5.13 MS -SIM-mode of operation of a GC mass spectrometer detector such that only  a single mass ion or a
selected number of discrete mass ions are monitored.

5.14 Standard Sorbent (Sample) Tube-stainless steel, glass or glass lined (or fused silica lined) stainless steel
tube,  1/4 inch (6 mm) O.D. and of various lengths, with the central portion packed with >200 mg of solid
adsorbent material depending on sorbent density.  Tubes should be individually numbered and show the direction
of flow.

5.15 Time Weighted Average (TWA) Monitoring-if air is sampled over a fixed time period - typically 1,3,
8 or 24 hours, the time weighted average atmospheric concentration over the monitoring period may be calculated
from the  total mass of analyte retained and the  specific air volume sampled.  Constraints on breakthrough
volumes make certain combinations of sampling time and flow rates mutually exclusive.
6. Overview of Methodology

[Note:  The following is intended to provide a simple and straightforward method description including the
example of a specific sampling problem. Although specific equipment is listed, the document is intended only
as an example and equipment mentioned in the text is usually only one of a number of equally suitable
components that can be used. Hence trade names are not meant to imply exclusive endorsement for sampling
and analysis using solid sorbents.  Later sections in the text give guidance as to what considerations should
be made for a number of VOC monitoring applications.}
Page 17-6            Compendium of Methods for Toxic Organic Air Pollutants        January 1999

-------
VOCs	Method TO-17

6.1 Selection of Tube and Sorbent

   6.1.1  Select a tube and sorbent packing for the sampling application using guidance from Tables 1 and 2 on
sorbent characteristics as well as guidance from Appendix 1 and Table 3 on safe sampling volumes  and
breakthrough characteristics of sorbents.
   6.1.2  As an example, assume the TCL includes a subset of the compounds shown in Table 3. In this case,
the multisorbent tube chosen consists of two sorbents packed in a 1/4 inch O.D., 3.5" long glass tube in the
following order and amounts:  160 mg of Carbopack™ graphitized carbon black (60/80 mesh)  and 70 mg of
Carboxen™-1000 type carbon molecular sieve (60/80 mesh).  This is an example of Tube Style 2 discussed
Section 9.1.3.2.
   6.1.3  Pack the tube with the adsorbent by using the guidance provided in Section 10.1 or buy a prepacked
tube from a supplier. In the example, tubes were purchased from Supelco Inc., Supelco Park, Bellefonte, PA
16823-0048.

6.2 Conditioning the Tube

   6.2.1  Condition newly packed tubes for at least 2 hours (30 mins for preconditioned, purchased tubes) at
350°C while passing at least 50 mL/min of pure helium carrier gas through them.

[Note: Other sorbents may require different conditioning temperatures - see Table 2 for guidance.]

Once conditioned, seal the tube with brass, 1/4 inch Swagelok® -type fittings and PTFE ferrules.  Wrap the
sealed tubes in uncoated aluminum foil and place the tubes in a clean, airtight, opaque container.
   6.2.2  A package of clean sorbent material, e.g. activated charcoal or activated charcoal/silica gel mixture,
may be added to the container to ensure clean storage conditions.
   6.2.3  Store in a refrigerator (organic solvent-free) at 4°C if not to be used within a day. On second and
subsequent uses, the tubes will generally not require further conditioning as above. However,  tubes with an
immediate prior use indicating high levels of pollutant trace gases should be reconditioned prior to continued
usage.

6.3 Sampling Apparatus

   6.3.1   Select a sampling apparatus with accommodations for two  sampling tubes capable of independent
control of sampling rate at a settable value in the range 10 to 200 mL/min. Laboratory and field blanks must also
be included in the monitoring exercise.
   6.3.2  Backup tubes may be required to determine the cause of any problem if performance criteria, outlined
in Section 14, are not met.

6.4 Sampling Rates

   6.4.1   Select sampling rates compatible with the collection of 1  and 4 liter total sample volume (or of
proportionally lower/higher sampling volumes).
   6.4.2  Air samples are collected over 1 hour with  a  sampling rate of 16.7 mL/min and 66.7 mL/min,
respectively.
January 1999        Compendium of Methods for Toxic Organic Air Pollutants            Page 17-7

-------
Method TO-17	VOCs

6.5 Preparing for Sample Collection

   6.5.1  At the monitoring location, keep the tubes in their storage and transportation container to equilibrate
with ambient temperature.
   6.5.2 Using clean gloves, remove the sample tubes from the container, take off their caps and attach them
to the sampling lines with non-outgassing flexible tubing. Uncap and immediately reseal the required number
of field blank tubes.
   6.5.3  Place the field blank tubes back in the storage container. If back-up tubes are being used, attach them
to the sampling tubes using clean, metal Swagelok® type unions and combined PTFE ferrules.

6.6 Set the Flow Rates

   6.6.1  Set the flow rates of the pump using a mass flow monitor.
   6.6.2  The sampling train includes,  from front to back,  an in-line particulate filter (optional), an ozone
scrubber  (optional), a sampling  tube, a back-up tube  if any is being used,  and a flow controller/pump
combination.
   6.6.3  Place  the mass flow monitor in line after the tube. Turn the pump on and wait for one minute.
Establish the approximate sampling flow  rate using a dummy  tube of identical construction and packing as the
sampling tube to  be used. Record on Field Test Data Sheet (FTDS), as illustrated in Figure 1.
   6.6.4  Place  the sampling tubes to be used on the sampling train and make  final adjustments to the flow
controller as quickly as possible to avoid significant errors in the sample volume.
   6.6.5  Adjust the flow rate of one tube  to sample at 16.7 mL/min. Repeat the procedure for the second tube
and set the flow rate to 66.7 mL/min. Record on FTDS.

6.7 Sample and Recheck Flow Rates

   6.7.1  Sample over the selected sampling period (i.e., 1 -hour).  Recheck all the sampling flow rates at the end
of the monitoring exercise just before switching off each pump and record on FTDS.
   6.7.2  Make  notes of all relevant monitoring parameters including locations, tube identification numbers,
pump flow rates,  dates, times, sampled volumes, ambient conditions etc. on FTDS.

6.8 Reseal the Tubes

   6.8.1  Immediately remove the sampling tubes with clean gloves, recap the tubes with Swagelok® fittings
using PTFE ferrules, rewrap the tubes with uncoated Al foil, and place the tubes in a clean, opaque, airtight
container.
   6.8.2  If not to be analyzed during the same day, place the container in a clean, cool (<4 ° C), organic solvent-
free environment and leave there until time for analysis.

6.9 Selection of Thermal Desorption System

   6.9.1  Select a thermal desorption system using the guidance provided in Section 8.
   6.9.2 Place the thermal unit in a ready operational status.
Page 17-8            Compendium of Methods for Toxic Organic Air Pollutants        January 1999

-------
VOCs	Method TO-17

6.10 Dry Purge the Tubes and Prepare for Thermal Desorption

   6.10.1 Remove the sampling tubes, any backup tubes being used, and blanks from the storage area and allow
the tubes to come to room temperature. Using clean gloves, remove the Swagelok®-type fittings and dry purge
the tubes with a forward (sampling direction) flow of, for example, 50 mL/min of dry helium for 4 minutes (see
Section 7.2 concerning dry purging).

[Note: Do not dry purge the laboratory blanks.]

   6.10.2 Reseal the tubes with Teflon® (or other) caps compatible with the thermal desorber operation.  Place
the sealed tubes on the thermal desorber (e.g., Perkin Elmer Model AID 400 Automated System or equivalent).
Other thermal desorbers may have different arrangements for automation. Alternatively, use equivalent manual
desorption.

6.11 Check for System Integrity

   6.11.1 Check the air tightness of the seals and the integrity of the flow path.
   6.11.2 Guidance is provided in Section 11.2 of this document.

6.12 Repurge of Tube on the Thermal Desorber/Addition of Internal Standard

   6.12.1 Because of tube handling after dry purge, it may be necessary to repurge each of the tubes with pure,
dry helium (He) before analysis in order to eliminate any oxygen.
   6.12.2 If the initial dry purge can be performed on the thermal desorber so as to prevent any further exposure
of the sorbent to air, then this step is not necessary. Proceed with the addition of an internal standard to the
sorbent tube or the focusing tube.

6.13 Thermally Desorb the Packing

   6.13.1  Reverse the flow direction of He gas, set the flow rate to at least 30 mL/min, and heat the tube to
325 °C (in this case) to achieve a transfer of VOCs onto a focusing tube at a temperature of 27°C. Thermal
desorption continues until all target species are transferred to the focusing trap.  The focusing trap is typically
packed with 20 mg of Carbopack™ B  (60/80 mesh) and 50 mg of a Carboxen™ 1000-type sorbent (60/80
mesh).

6.14 Trap Desorption and GC/MS Analysis

   6.14.1 After each tube is desorbed,  rapidly  heat the focusing trap (to 325 °C in this example) and apply a
reverse flow of at least 3 mL/min of pure  helium  carrier gas.  Sample splitting is necessary to accommodate the
capillary column. Analytes are transferred to the column in a narrow band of vapor.
   6.14.2 The GC run is initiated based on a time delay after the start of thermal desorption. The remaining
part of the analytical cycle is described in Section 3 of Compendium Method TO-15.

6.15 Restoring the Tubes and Determine Compliance with Performance Standards
January 1999        Compendium of Methods for Toxic Organic Air Pollutants            Page 17-9

-------
Method TO-17	VOCs

   6.15.1 When tube analysis is completed, remove the tubes from the thermal desorber and, using clean gloves,
replace the Teflon® caps with Swagelok fittings and PTFE ferrules, rewrap with aluminum foil, replace in the
clean, airtight container, and re-store the tubes in a cool environment (<4°C) until the next use.
   6.15.2 Using previously prepared identification and quantification subroutines, identify the target compounds
and document the amount of each measured compound (refer to the Section 3 of Compendium Method TO-15).
Compare  the results of analysis for the distributed volume pair taken during each sampling run and use the
comparison to determine whether or not the performance criteria for individual sampling events have been met.
Also examine the results of any laboratory blanks, field blanks, and any backup tube being used. Accept or reject
the data based on the performance criteria (see Section 14).

6.16 Record and Store Data

   6.16.1 Accurately retrieve field data (including the tube identification number) from the FTDS. The data
should include a sampling site identifier, time of sample initiation, duration of sampling, air pump identification,
flow rate,  and other information as appropriate.
   6.16.2 Store GC/MS data in a permanent form both in hard copy in a notebook and in digital form on a disk.
Also store the data  sheet with the hard copy.

[Note:  Sections 7 through 14 below elaborate on the method by providing important information and
guidance appropriate to explain the method as outlined in Section 6 and also to generalize the method for
many applications. Section 14 gives the performance criteria for the method.]
7. Interferences and Limitations

7.1 Interference from Sorbent Artifacts

    7.1.1 Minimizing Artifact Interference.
      7.1.1.1  Stringent tube conditioning (see Section 10.2.1) and careful tube capping and storage procedures
(see Section 10.2.2) are essential for minimizing artifacts. System and sorbent tube conditioning must be carried
out using more stringent conditions of temperature, gas flow and time than those required for sample analysis.
      7.1.1.2  A reasonable objective is to reduce artifacts to 10% or less of individual analyte masses
retained during sampling. A summary of VOC levels present in a range of different atmospheric environments
and the masses of individual components collected from 1, 2 or 10 L samples of air in each case is presented in
Table 4.
      7.1.1.3  Given that most ambient air monitoring is carried out in areas of poor air quality, for example in
urban, indoor and factory fenceline environments where VOC concentrations are typically above 1 ppb, Table 4
demonstrates that  the mass of each analyte retained will, therefore, range from ~5 ng to -10 /j,g in most
monitoring situations. Even when monitoring 'ultraclean' environments, analyte masses retained will usually
exceed 0.1 ng (3).
      7.1.1.4 Typical artifact levels for 1/4 inch O.D. tubes of 3.5" length range from 0.01 ng and 0.1 ng for
carbonaceous sorbents and Tenax® respectively. These levels compare well with the masses of analytes collected
- even  from sub-ppb  atmospheric  concentrations  (see Table 4).   Artifact levels  are around 10 ng  for
Chromosorb® Century series and other porous polymer sorbents. However, these types of sorbents can still be
used for air monitoring at low ppb levels if selective or mass spectrometer detectors are used or if the blank
profile of the tube demonstrates that none of the sorbent artifacts interfere analytically with the compounds of
interest.
Page 17-10           Compendium of Methods for Toxic Organic Air Pollutants        January 1999

-------
VOCs	Method TO-17

      7.1.1.5  Some varieties of charcoal contain metals which will catalyze the degradation of some organic
analytes during thermal desorption at elevated temperatures thus producing artifacts and resulting in low analyte
recoveries.
    7.1.2 Artifacts from Long-term Storage of Blank Tubes.
      7.1.2.1 Literature reports of the levels of artifacts on (a) Carbotrap/pack™ C, Carbotrap/pack™ B and
Carbosieve™  SIII multi-bed tubes and (b) Tenax® GR tubes, by workers sealing the tubes using metal
Swagelok®-type caps and PTFE ferrules with multi-tube, glass storage jars are reported to be between 0.01 ng
[after 1-2 months (4)] and 0.1 ng [after 6 months (5)] for (a) and (b) respectively.
      7.1.2.2 Artifact levels reported for other porous polymers are higher - for example 5 ng for Chromosorb
106 after 1 week (5). More information is given in the Technical Assistance Document (TAD) referred to in
Section 4.3.
    7.1.3 Artifacts Generated During Sampling and Sample Storage.
      7.1.3.1 Benzaldehyde, phenol and acetophenone artifacts are reported to be formed via oxidation of the
polymer Tenax® when  sampling high concentration (100-500 ppb) ozone atmospheres (6).
      7.1.3.2 Tenax® should thus be used with an ozone scrubber when sampling low levels (<10 ppb) of these
analytes in areas with appreciable ozone concentrations. Carbotrap™/pack type sorbents have not been reported
to produce this level of artifact formation.  Once retained on a sorbent tube, chemically stable VOCs, loaded in
laboratory conditions, have been shown to give good recoveries, even under high ozone concentrations for storage
of a year or more (7-9).

7.2  Minimizing Interference from Water

    7.2.1 Selection of Hydrophobic Sorbents
      7.2.1.1 There are three preferred approaches to reducing water interference during air monitoring using
sorbent tubes. The first is to minimize water collection by selecting, where possible, a hydrophobic sorbent for
the  sample tube.
      7.2.1.2 This is possible for compounds ranging in volatility from n-C5 (see SSVs listed in Appendix 1).
Tenax®, Carbotrap™ or one  of the other hydrophobic sorbents listed in Table 2 should be used.

[Note: It is essential to ensure that the temperature of the sorbent tube is the same and certainly not lower
than ambient temperature at the start of sampling or moisture will be retained via condensation,  however
hydrophobic the sorbent.]

    7.2.2 Sample Splitting
      7.2.2.1 If the sample loading is high, it is usually possible to eliminate sufficient water to prevent analytical
interference by using sample  splitting (10).
      7.2.2.2 Sample may be split either (1) between the focusing trap and the capillary column (single splitting)
during trap (secondary) desorption or (2) between both the tube and the focusing trap during primary (tube)
desorption and between the focusing trap and the column during secondary (trap) desorption (see Section 8.2.3)
(double splitting).  It may, in fact, be necessary to split the sample in some cases to prevent overloading the
analytical column or detector.
    7.2.3 Dry Purge
      7.2.3.1 The third water management method is to ?dry purge" either the sorbent tube itself or the focusing
trap or both (11-13). Dry purging the sample tube or focusing trap simply involves passing a volume of pure,
dry, inert gas through the tube from the sampling end, prior to analysis.
January 1999         Compendium of Methods for Toxic Organic Air Pollutants           Page 17-11

-------
Method TO-17	VOCs

      7.2.3.2 The tube can be heated while dry purging at slightly elevated temperatures (11).  A trap packing
combination and a near ambient trapping temperature must be chosen such that target analytes are quantitatively
retained while water is purged to vent from either the tube or trap.

7.3 Atmospheric Pollutants not Suitable for Analysis by this Method

   7.3.1 Inorganic gases not suitable for analysis by this method are oxides of carbon, nitrogen and sulfur, O3
and other permanent gases. Exceptions include CS2 and N2O.
   7.3.2 Other pollutants not suitable are particulate pollutants, (i.e., fumes, aerosols and dusts) and compounds
too labile (reactive) for conventional GC analysis.

7.4 Detection Limits and Maximum Quantifiable Concentrations of Air Pollutants

   7.4.1  Detection limits for atmospheric monitoring vary depending on several key factors. They are:

   •  Minimum artifact levels.
   •  GC detector selection.
   •  Volume of air sampled. The volume of air sampled is in turn dependent upon a series of variables
      including SSVs (see Section 10.8, Table 1  and Appendix 1), pump  flow rate limitations and time-
      weighted-average monitoring time constraints.

   7.4.2 Generally speaking, detection limits range from sub-part-per-trillion (sub-ppt) for halogenated species
such as CC14 and the freons using an electron capture detector (BCD) to sub-ppb for volatile hydrocarbons in 1
L air samples using the GC/MS operated in the full SCAN mode.
   7.4.3 Detection limits are greatly dependent upon the proper management of water for GC capillary analysis
of volatile organics in air using sorbent technology (14).

7.5 Suitable Atmospheric Conditions

   7.5.1  Temperature range.
      7.5.1.1 The normal working range for sorbent packing is 0-40°C (8).
      7.5.1.2 In general, an increase in temperature of 10°C will reduce the breakthrough volume for sorbent
packings by a factor of 2.
   7.5.2  Humidity
      7.5.2.1  The capacity of the analytical instrumentation to accommodate  the amount of water vapor
collected on tubes is usually the limitation in obtaining successful results, particularly for GC/MS applications.
This limitation can be extreme, requiring the use of a combination of water management procedures (see Section
7.2).
      7.5.2.2 The safe sampling volumes of VOCs on hydrophobic adsorbents such as Tenax®, other porous
polymers, Carbotrap™ and Carbopack™ are relatively unaffected by atmospheric humidity. Spherocarb® or
carbonized molecular sieve type sorbents such as Carbosieve™ SIII and the Carboxens®  are affected by high
humidity, however, and SSVs should typically be reduced by a factor of 10 at 90-95% RH (8). Hydrophilic
zeolite molecular sieves cannot be used at all at high humidity.
   7.5.3  Wind speeds.
      7.5.3.1 Air movement is not a factor indoors or outdoors at wind speeds below 10  miles per hour (<20
km per hour).
Page 17-12           Compendium of Methods for Toxic Organic Air Pollutants         January 1999

-------
VOCs	Method TO-17

      7.5.3.2 Above this speed, tubes should be orientated perpendicular to the prevailing wind direction and
should be sheltered from the direct draft if wind speeds exceed 20 miles per hour (30-40 km per hour) (see
Section 10.5).
   7.5.4 High concentrations of particulates.
      7.5.4.1 It may be necessary to connect a particulate filter (e.g., a 2 micron Teflon® filter or short clean
tube containing a loose plug of clean glass wool) to the sampling end of the tube in areas of extremely high
particulate concentrations.
      7.5.4.2  Some compounds of interest may, however, be trapped on the  Teflon® or on the glass wool.
Particulates trapped on the sorbent tube have the potential to act as a source or sink for volatiles, and may remain
on the tube through several cycles of sampling and desorption. Frequent replacement of the particulate filter is
therefore recommended.
8. Apparatus Selection and Preparation

8.1 Sample Collection

   8.1.1  Selection of Tube Dimensions and Materials.
      8.1.1.1 The most extensively used sorbent tubes are 1/4 inch O.D. stainless steel or 6 mm O.D. stainless
steel or glass. Different suppliers provide different size tubes and packing lengths; however, 3.5 inch long tubes
with a 6 cm sorbent bed and 1/4 inch O.D. stainless steel (see Figure 2) were used to generate the SSV
information presented in Appendix 1.
      8.1.1.2  As an approximate measure, for sorbents contained in equal diameter tubes the breakthrough
volume is proportional to the  bed-length (weight) of sorbent.  Therefore, doubling the bed-length  would
approximately double the SSV (15).
      8.1.1.3 Stainless steel (304 or "GC" grade) is the most robust of the commonly available tube materials
which include, in addition,  glass, glass-lined, and fused silica lined tubing.  Tube material must be chosen to be
compatible with the specifics of storage and transport of the samples. For example, careful attention to packaging
is required for glass tubes.
   8.1.2  Tube Labeling.
      8.1.2.1  Label sample tubes with a unique identification number  and the direction of sampling flow.
Stainless steel tubes are most conveniently labeled by engraving. Glass tubes are best labeled using a temperature
resistant paint. If empty sample tubes are obtained without labels, it is important to label and condition them
before they are packed with adsorbent.
      8.1.2.2  Recondition prepacked, unlabeled tubes after the tube labeling process and record the blank
chromatogram from each tube.  Record in writing the details of the masses and/or bed lengths of sorbent(s)
contained in each tube, the maximum allowable temperature for that tube and the date each tube was packed or
repacked.
   8.1.3  Blank and Sampled Tube Storage Apparatus.
      8.1.3.1 Seal clean, blank sorbent tubes and sampled tubes using inert,  Swagelok®-type fittings and PTFE
ferrules. Wrap capped tubes individually in uncoated aluminum foil. Use clean, scalable glass j ars or metal cans
containing a small packet of activated charcoal or  activated charcoal/silica gel for storage and transportation of
multiple tubes. Store the multi-tube storage container in a clean environment at 4°C.
      8.1.3.2 Keep the sample tubes  inside the storage container during transportation and only remove them
at the monitoring location after the tubes have reached ambient temperature. Store sampled tubes in a refrigerator
at 4°C inside the multi-tube container until ready for analysis.
January 1999         Compendium of Methods for Toxic Organic Air Pollutants           Page 17-13

-------
Method TO-17	VOCs

[Note: The atmosphere inside the refrigerator must be clean and free of organic solvents.]

   8.1.4  Selection of Sampling Pumps.
      8.1.4.1 The selected monitoring pump(s) should be capable of operating in the range 10 to 200 mL/min.
Label the pumps with a unique identification number and operate them according to manufacturer's guidelines.
      8.1.4.2 Constant mass flow type pumps are ideal for air monitoring as they deliver a constant flow rate
for a wide range of tube impedances.  They thus compensate for moderate impedance variations between the
sorbent tubes in use. The pump should meet US criteria for intrinsic safety where applicable. Connect the pump
to the non-sampling end of the sample tube by means of flexible, nonoutgassing tubing.
   8.1.5  Parallel Sampling onto Multiple Tubes with a Single Pump.
      8.1.5.1 Select a sample collection system for collecting samples onto 2 tubes in parallel.
      8.1.5.2 If a single pump is used for both tubes, ensure that the flow rates will be controlled at a constant
flow rate during sampling and that the two flow rates can be independently controlled and stabilized.
   8.1.6  Apparatus for Calibrating the Pumped Air Flow.
      8.1.6.1  Calibrate the pump with the type  of sorbent tube to which it will be connected during the
monitoring exercise. Use the  actual sampling tube to fine tune the sampling flow rate at the start of sample
collection.
      8.1.6.2 Use a flow meter certified traceable to NIST standards.
   8.1.7  Sorbent Tube Protection During Air Sample Collection.
      8.1.7.1  Protect sorbent tubes from extreme weather conditions  using shelters constructed of inert
materials.  The shelter must not impede the ingress of ambient air.
      8.1.7.2  If the atmosphere under test contains significant levels of particulates - fume, dust or aerosol,
connect a Teflon® 2-micron filter or a (metal, glass, glass-lined or fused silica lined stainless) tube containing
a short plug of clean glass wool prior to the sampling end of the tube and using inert, Swagelok®-type fittings
and PTFE ferrules for fitting connections.

8.2 Apparatus

   8.2.1  Essential Sample Protection Features of the Thermal Desorption Apparatus.
      8.2.1.1 As thermal desorption is generally a one shot process, (i.e., once the sample is desorbed it cannot
readily be reinjected or retrieved), stringent sample protection measures and thorough preanalysis system checks
must form an integral part of the thermal desorption-GC procedure and should be systematically carried out.
      8.2.1.2 The sample integrity protection measures and preanalysis checks required include:

   •   Sealed tubes.  Sample tubes awaiting analysis on an automated desorption  system must be completely
      sealed before thermal desorption to prevent ingress of VOC contaminants from the laboratory air and to
      prevent losses of weakly retained analytes from the tube.
   •   Inert and heated sample flow path. To eliminate condensation, adsorption and degradation of analytes
      within the analytical system, the sample flow path of manual and automated thermal desorbers should be
      uniformly heated (minimum temperature range 50°  - 150°C) between the sample tube  and the GC
      analytical column. The components of the sample flow path should also, as far as possible, be constructed
      of inert materials, i.e., deactivated fused silica, glass lined tubing, glass, quartz and PTFE.
   •   Tube leak testing. This activity must not jeopardize sample integrity.
   •   Leak testing of the sample flow path.  This activity must not jeopardize sample integrity.
   •   System purge. Stringent, near-ambient temperature carrier gas purge to remove oxygen.
   •   Analytical  system. ?Ready" status checks.
Page 17-14           Compendium of Methods for Toxic Organic Air Pollutants        January 1999

-------
VOCs                                                                              Method TO-17
   8.2.2 Thermal Desorption Apparatus.
      8.2.2.1 Two-stage thermal desorption is used for the best high resolution capillary chromatography (i.e.,
analytes desorbed from the sorbent tube must be refocused before being rapidly transferred to the GC analytical
column). One type of analyte refocusing device which has been successfully used is a small sorbent trap (17).
One cryogen-free trap cooling option is to use a multistage Peltier electrical cooler (18,19).
      8.2.2.2  Closed cycle coolers are also available for use. At its low temperature, the trap must provide
quantitative analyte retention for target compounds as well as quantitative and rapid desorption of target analytes
as high boiling as n-C12.  The peak widths produced must be compatible with high resolution capillary gas
chromatography.
      8.2.2.3  Typical key components and operational stages of a two-stage desorption system are presented
in Figure 3(a) - (f) and a stepwise description of the thermal desorber operation is presented in Section 11.3.
   8.2.3 Sample Splitting Apparatus.
      8.2.3.1 Sample splitting is often required to reduce water vapor interference, for the analysis of relatively
high concentration (>10 ppb level) air samples, when large volume air samples are collected, or when sensitive
selective detectors are in use.
      8.2.3.2 Sample splitting is one of the three key approaches to water management detailed in this method
(see Section 7.2).  Moisture management by sample splitting is applicable to relatively high concentrations (> 10
ppb) or large volume air samples or to analyses employing extremely sensitive detectors - for example, using the
BCD for low levels of tetrachloroethylene.  In these cases the masses of analytes retained by the sorbent tube
when monitoring such atmospheres is large enough to allow, or even require, the selection of a high split ratio
(>10:1) during analysis to avoid overloading the analytical column or detector.  The mass of water retained by
the sorbent tube during sample collection may be sufficiently reduced by the split alone to eliminate the need for
further water management steps.
   8.2.4 The Thermal Desorber - GC Interface.
      8.2.4.1 Heat the interface between the thermal desorber and the GC uniformly. Ensure that the interface
line is leak tight and lined with an inert material such as deactivated fused silica.
      8.2.4.2  Alternatively, thread the capillary column itself through the heated transfer line/interface and
connected directly into the thermal desorber.

[Note:  Use of a metal syringe-type needle or unheated length of fused silica pushed through the septum of
a conventional GC injector is not recommended  as  a means of interfacing the thermal  desorber to the
chromatograph. Such connections result in cold spots, cause band broadening and are prone to leaks.]

   8.2.5 GC/MS Analytical Components. This method uses the GC/MS description as given in Compendium
Method TO-15, Section 7.

8.3 Tube Conditioning Apparatus

   8.3.1 Tube Conditioning Mode
      8.3.1.1  Condition freshly packed tubes using the analytical thermal desorption apparatus if it supports
a dedicated 'tube conditioning mode' (i.e., a mode in which effluent from highly contaminated tubes is directed
to vent without passing through key parts of the sample flow path such as the focusing trap).
   8.3.2 Stand Alone System
      8.3.2.1  If such a tube conditioning mode is not available, use separate stand-alone tube conditioning
hardware.
January 1999         Compendium of Methods for Toxic Organic Air Pollutants           Page 17-15

-------
Method TO-17	VOCs

      8.3.2.2  The tube conditioning hardware must be leak-tight to prevent air ingress, allow precise and
reproducible temperature selection (±5°C), offer a temperature range at least as great as that of the thermal
desorber and support inert gas flows in the range of 50 to 100 mL/min.

[Note: Whether conditioning is carried out using a special mode on the thermal desorber or using separate
hardware, pass effluent gases from freshly packed or highly contaminated tubes through a charcoal filter
during the process to prevent desorbed VOCs polluting the  laboratory atmosphere.]
9. Reagents and Materials

9.1 Sorbent Selection Guidelines

   9.1.1  Selection of Sorbent Mesh Size.
      9.1.1.1 Sieved sorbents of particle size in the range 20 to 80 mesh should be used for tube packing.
      9.1.1.2 Specific surface area of different sorbents is provided in Table 2.
   9.1.2  Sorbent Strength and Safe Sampling Volumes.
      9.1.2.1 Many  well-validated pumped and diffusive sorbent tube sampling/thermal desorption methods
have been published at the relatively high atmospheric concentrations (i.e., mid-ppb to ppm) typical of workplace
air and industrial/mobile source emissions (8, 20-30).
      9.1.2.2 These methods show that SSVs are unaffected by analyte concentrations far in excess of the 25
ppb upper limit of this method.  The effect of humidity on SSVs is discussed in Section 7.5 and Table 2.
      9.1.2.3  Select a sorbent or series of sorbents of suitable strength for the analytes in question from the
information given in Tables 1 and 2 and Appendices 1 and 2. Where a number of different sorbents fulfill the
basic safe sampling volume criteria for the analytes in question, choose that (or those) which are hydrophobic
and least susceptible to artifact formation.  Keep the field sampling volumes to 80% or less of the SSV of the
least well-retained analyte. Using one of the two procedures given in Section 10.8, check the safe sampling
volumes  for the most volatile analytes of interest on an annual basis or once every twenty uses of the sorbent
tubes whichever occurs first.
   9.1.3  Three General-Purpose 1/4 Inch or 6 mm O.D. Multi-Bed Tube Types.

[Note:  The three general-purpose tubes presented in this section are packed with sorbents in  the mesh size
range of 20-80 mesh.  The difference in internal diameter between standard glass and stainless steel tubes
will result in different bed volumes (weights) for the same bed length.]

      9.1.3.1 Tube Style 1 consists of 30 mm Tenax®GR plus 25 mm of Carbopack™ B separated by 3 mm
of unsilanized, preconditioned glass or quartz wool. Suitable for compounds ranging in volatility from n-C6 to
n-C20 for air volumes of 2 L at any humidity. Air volumes may be extended to 5 L or more for compounds
ranging in volatility from n-C7.
      9.1.3.2Tube Style 2 consists of 35 mm Carbopack™ B plus 10 mm of Carbosieve™ SIII or Carboxen™
1000 separated by glass/quartz wool as above.  Suitable for compounds ranging in volatility from n-C3 to n-C12
(such as ?Compendium Method TO-14 air toxics") for air volumes of 2 L at relative humidities below 65% and
temperatures below 30°C. At humidities above 65% and ambient temperatures above 30°C, air volumes should
be reduced to 0.5 L. Air volumes may be extended to 5 L or more for species ranging in volatility from n-C4.
A dry purge procedure or a large split ratio must be used during analysis when humid air has been sampled on
these tubes.
Page 17-16           Compendium of Methods for Toxic Organic Air Pollutants        January 1999

-------
VOCs	Method TO-17

      9.1.3.3  Tube Style 3 consists of 13 mm Carbopack™ C, 25 mm Carbopack™ B plus 13 mm of
Carbosieve™ SIII or Carboxen™ 1000 all separated by 3 mm plugs of glass/quartz wool as above.  Suitable for
compounds ranging in volatility from n-C3 to n-C16 for air volumes of 2 L at relative humidities below 65 percent
and temperatures below 30°C.  At humidities above 65 percent and ambient temperatures above 30°C, air
volumes should be reduced to 0.5 L. Air volumes may be extended to 5 L or more for compounds ranging in
volatility from n-C4. A dry purge procedure or a large split ratio must be used during analysis when humid air
has been sampled on these tubes.

[Note: These multi-bed tubes are commercially available prepacked and preconditioned if required.]

[Note: These general purpose multi-bed tubes are only recommended for monitoring unknown atmospheres
or wide volatility range sets of target analytes. Most routine monitoring of industrial air (for example at
factory fencelines) only  involves monitoring a few specific target analytes such  as benzene,  toluene,
ethylbenzene, andxylenes (BTEX), carbon disulfide (CS^ or 1,1,1-trichloroethane. Single-bed sorbent tubes
selected from the options listed in Appendix 1 are typically used in these cases.]

[Note:  In the interests of minimizing water retention it is advisable to stick to hydrophobic (i.e., weak and
medium strength) sorbents whenever possible; this generally is the case when components more volatile than
n-C6 are not of interest.]

9.2 Gas Phase Standards

   9.2.1 Standard Atmospheres.
      9.2.1.1   Standard atmospheres must be stable at ambient pressure  and accurate (±10%).  Analyte
concentrations and humidities should be similar to those in the typical test atmosphere.  Standard atmospheres
must be sampled onto conditioned sorbent tubes using the same pump flow rates as  used for field sample
collection.
      9.2.1.2  If a suitable standard atmosphere is obtained commercially, manufacturer's recommendations
concerning storage conditions and product lifetime should  be rigidly observed.
   9.2.2 Concentrated, Pressurized Gas Phase Standards.
      9.2.2.1 Use accurate (± 5%), concentrated gas phase  standards in pressurized cylinders such that a 0.5 -
5.0 mL gas sampling volume (GSV) loop contains approximately the same masses of analytes as will be collected
from a typical air sample.  Introduce the standard onto the sampling end of conditioned sorbent tubes using at
least ten times the loop volume of pure helium carrier gas to completely sweep the standard from the GSV.
      9.2.2.2 Manufacturer's guidelines concerning storage conditions and expected lifetime of the concentrated
gas phase standard should be rigidly observed.

9.3 Liquid Standards

   9.3.1 Solvent Selection.
      9.3.1.1  If liquid standards are to be loaded onto sorbent tubes for calibration purposes, select a solvent
for the standard that is pure (contaminants <10% of minimum analyte levels) and that, if possible, is considerably
more volatile than the target analytes. This then allows the solvent to be purged and eliminated from the tube
during the standard preparation process.
      9.3.1.2  Methanol most commonly fills these criteria.  If the target analyte range includes very volatile
components, it  will not be  possible to  do this.   In these cases, select a pure solvent which is readily
chromatographically resolved from the peaks/components of interest (ethyl acetate is commonly used) or use a
January 1999         Compendium of Methods for Toxic Organic Air Pollutants          Page 17-17

-------
Method TO-17	VOCs

gas phase standard. Test the purity of the solvent by comparing an analysis of the prepared standard with an
analysis of pure solvent under identical chromatographic conditions.
   9.3.2 Liquid Standard Concentrations.
      9.3.2.1 Liquid standards should be prepared so that the range of analyte masses introduced onto the tubes
is in the same order as the range of masses expected to be collected during sampling.
      9.3.2.2 Concentrations of benzene in urban air may be expected to range from 0.5-25 ppb. Thus if 5 L
air samples were to be collected at approximately 25 °C, the masses of benzene collected would range from
around 8 ng (0.5 ppb level) to around 400 ng (25 ppb level).

[Note: The above calculation was derived from Boyle's law (i. e.,  1 mole of gas occupies around 25 L at 25° C
and  760 mm Hg).
      25 L of pure benzene vapor contains 78 g benzene
      5 L of pure benzene vapor contains 15.6 g benzene
      5 L of a 1 ppm benzene atmosphere contains 15.6 jj,g benzene
      5 L of a 100 ppb benzene atmosphere contains 1560 ng benzene
      5 L of a 1 ppb benzene atmosphere contains 15.6 ng benzene.]
   9.3.3 Loading Liquid Standards onto Sorbent Tubes.
      9.3.3.1 Introduce 0.1 -10 //L aliquots of the liquid standards onto the sampling end of conditioned sorbent
tubes using a conventional 1/4 inch GC packed column injector and a 1, 5 or 10 /J.L syringe. The injector is
typically unheated with a 100 mL/min flow of pure carrier gas.  The solvent and analytes should completely
vaporize and pass onto the sorbent bed in the vapor phase. It may be necessary to heat the injector slightly
(typically to 50°C) for analytes less volatile than n-C12 to ensure that all the liquid vaporizes.
      9.3.3.2  The sample tube should remain attached to the injector until the entire standard has been swept
from the injector and onto the sorbent bed. If it has been possible to prepare the liquid standard in a solvent
which will pass through the sorbent while analytes are quantitatively retained (for example, methanol on Tenax®
or Carbopack™ B), the tube should not be disconnected from the injector until the solvent has been eliminated
from the sorbent bed - this takes approximately 5 minutes under the conditions specified. Once the tube has been
disconnected from the injector, it should be capped and placed in an appropriate storage container immediately.

[Note:  In cases where it is possible to purge the solvent from the tube while quantitatively retaining the
analytes, a 5-10 jj,L injection should be made as this can usually be introduced more accurately than smaller
volumes.  However,  if the solvent is to be retained in the tube, the injection volume should be as small as
possible (0.5 - 1.0 iJ,L) to minimize solvent interference in the subsequent chromatogram.]

      9.3.3.3  This method of introducing liquid standards onto sorbent tubes via a GC injector is considered
the optimum approach to liquid standard introduction as components reach the sorbent bed in the  vapor phase
(i.e., in a way which most closely parallels the normal air sample collection process). Alternatively, liquid
standards may be introduced directly onto the sorbent bed via the non-sampling end  of the tube using a
conventional GC syringe.

[Note: This approach is convenient and works well in most cases, but it may not be used for multi-bed tubes
or for wide boiling range sets of analytes and does not allow  solvent to be purged to vent.]
Page 17-18           Compendium of Methods for Toxic Organic Air Pollutants        January 1999

-------
VOCs	Method TO-17

9.4 Gas Phase Internal Standards

   9.4.1 The ideal internal standard components are:

   •  chemically similar to the target analytes
   •  extremely unlikely to occur naturally in the atmosphere under test
   •  readily resolved and distinguished analytically from the compounds of interest
   •  stable in the vapor phase at ambient temperature
   •  compatible with metal and glass surfaces under dry and humid conditions
   •  certified stable in a pressurized form for a long time period (i.e., up to 1 year).
   9.4.2  Deuterated  or fluorinated hydrocarbons usually  meet all these criteria and make perfect internal
standards for  MS based systems.   Typical compounds include deuterated toluene,  perfluorobenzene and
perfluorotoluene.  Multiple internal standards should be used if the target analytes cover a very wide volatility
range or several different classes of compound.
   9.4.3  Obtain a pressurized cylinder containing accurate (±5%)  concentrations of the internal standard
components selected. Typically a 0.5 to 5.0 mL volume of this standard is automatically introduced onto the back
of the sorbent tube or focusing trap after the tube has passed preliminary leak tests and before it is thermally
desorbed.  The concentration of the gas should be such that the mass of internal standard introduced from the
GSV loop is approximately equivalent to the mass of analytes which will be sampled onto the tube during sample
collection. For example, a 1 L air sample with average analyte concentrations in the order of 5 ppb, would require
a 10 ppm internal standard, if only 0.5 mL of the standard is introduced in each case.

9.5 Commercial, Preloaded Standard Tubes

   9.5.1 Certified, preloaded commercial standard tubes are available and should be used for auditing purposes
wherever possible to establish analytical quality control (see Section 14). They may also be used for routine
calibration.  Suitable preloaded standards should be accurate within ±5% for each analyte  at the microgram level
and ±10% at the nanogram level.
   9.5.2 The following information should be supplied with each preloaded standard tube:

   •  A chromatogram of the blank tube before the standard was loaded with associated analytical conditions
      and date.
   •  Date of standard loading
   •  List of standard components, approximate masses and associated confidence levels
   •  Example analysis of an identical standard with associated analytical conditions (these should be the same
      as for the blank tube)
   •  A brief description of the method used for standard preparation
   •  Expiration date

9.6 Carrier Gases

Inert, 99.999% or higher purity helium should be used as carrier gas. Oxygen and organic filters should be
installed on the carrier gas lines  supplying the analytical system.  These filters should be replaced regularly
according to the manufacturer's instructions.
January 1999         Compendium of Methods for Toxic Organic Air Pollutants           Page 17-19

-------
Method TO-17	VOCs



10. Guidance on Sampling and Related Procedures

10.1 Packing Sorbent Tubes

   10.1.1  Commercial Tubes
      10.1.1.1 Sorbent tubes are commercially available either prepacked and preconditioned or empty.
      10.1.1.2 When electing to purchase empty tubes and pack/condition them as required, careful attention
must be paid to the appropriate manufacturer's instructions.
   10.1.2  Tube Parameters
      10.1.2.1 Key parameters to consider include:

   •  Sorbent bed positioning within the tube.  The sampling surface of the sorbent bed is usually positioned
      at least 15 mm from the sampling end of the tube to minimize sampling errors due to diffusive ingress.
      The position of the sorbent bed must also be entirely within that section of the tube which is surrounded
      by the thermal desorption oven during tube desorption.
   •  Sorbent bed length. The sorbent bed must not extend outside that portion of the tube which is directly
      heated by the thermal desorption oven.
   •  Sorbent mesh size.  20 to 80 mesh size sorbent is recommended to prevent excessive pressure drop across
      the tube which may cause pump failure.  It is always recommended that sorbents be sieved to remove
      ?fines" (undersized particles) before use.
   •  Use of appropriate sorbent bed retaining hardware inside the tube. Usually 100 mesh stainless steel
      gauzes and retaining springs are used in stainless steel tubes and unsilanized, preconditioned glass or
      quartz wool in glass tubes.
   •  Correct conditioning procedures.  See Table 2 and Section 10.2.
   •  Bed separation. If a single tube is to be packed with two or three different sorbents, these must be kept
      in discreet beds separated by ~3 mm length plugs of unsilanized, preconditioned glass or quartz wool or
      glass fiber disks and arranged in order of increasing sorbent strength from the sampling end of the tube.
      Do not use sorbents of widely  different maximum temperatures in one tube or it will be  difficult to
      condition the more stable sorbents without exceeding the maximum recommended temperature of the less
      stable sorbents.

[Note: Silanized glass or quartz wool may  be used for labile species such as sulfur or nitrogen containing
compounds but should not be taken to temperatures above 250°C.]

   •  Compression of bed. The sorbent bed must not be compressed while packing the tube. Compression of
      the sorbent can lead to excessive tube impedance and may produce ?fines".

      10.1.2.2 Tubes packed with porous polymer sorbents (Chromosorbs®, Porapaks® and Tenax®) should
be repacked  after 100 thermal cycles or if the performance criteria cannot be met.   Tubes packed with
carbonaceous sorbents such as  Spherocarb®, Carbotrap™, Carbopack™, Carbosieve™ SIII and Carboxens®
should be repacked every 200 thermal cycles or if the safe sampling volume validation procedure fails.
Page 17-20           Compendium of Methods for Toxic Organic Air Pollutants        January 1999

-------
VOCs	Method TO-17

10.2 Conditioning and Storage of Blank Sorbent Tubes

   10.2.1  Sorbent Tube Conditioning.
      10.2.1.1  The success of sorbent tube sampling for ppb and sub-ppb level air monitoring is largely
dependent on artifact levels being at significantly lower levels (<10%) than the masses of analytes collected
during air monitoring.  A summary of recommended conditioning parameters for various individual sorbents and
multibed tubes is given in Table 2.  1/4 inch O.D. sorbent tubes may be adequately conditioned using elevated
temperatures and a flow of ultra-pure inert gas. Washing or any other preconditioning of the bulk sorbent is not
usually necessary. Appropriate, dedicated tube conditioning hardware should be used for tube conditioning unless
the thermal desorption system offers a separate tube conditioning mode.
      10.2.1.2  The tube conditioning temperatures and gas flows recommended in Table 2 should be applied
for at least 2 hours when a tube is packed with fresh adsorbent or when its history is unknown.

   Sorbent tubes which are:

   •  desorbed to completion during routine analysis (as is normally the case)
   •  stored correctly (see Section 10.2.2)
   •  re-issued for air sampling within 1 month (1 week for Chromosorb®, Tenax® and Porapak® porous
      polymers)
   •  and are to be used for atmospheres with analytes at the 10 ppb level or above

do not usually require any reconditioning at all before use.  However, tubes to be used for monitoring at lower
levels should be both reconditioned for 10-15 minutes using the  appropriate recommended  conditioning
parameters and put through a ?dummy" analysis using the appropriate analytical conditions to obtain blank
profiles of each tube before they are issued for sampling.
      10.2.1.3  Analytical system conditioning procedures are supplied by system manufacturers. Generally
speaking,  both  system and sorbent tube conditioning  processes must be carried out using more stringent
conditions of temperature, gas flow and time than those required for sample analysis  - within the maximum
temperature constraints of all the materials and equipment involved.
   10.2.2  Capping and Storage of Blank Tubes.
      10.2.2.1 Blank tubes should be capped with ungreased, Swagelok®-type, metal screw-caps and combined
PTFE ferrules. The  screw caps should be tightened by hand and then an extra 1/4 turn with a wrench. If uncoated
aluminum foil is required, tubes should be wrapped individually.
      10.2.2.2  Batches of blank, sealed tubes should be stored and transported inside a suitable multi-tube
container.

10.3 Record Keeping Procedures for Sorbent Tubes

Sample  tubes should be indelibly labeled with a unique identification number as described in Section 8.1.2.
Details  of the masses  and/or bed lengths of sorbent(s)  contained in each tube, the maximum allowable
temperature for that tube and the date each tube was packed should be permanently recorded. A record should
also be made each time a tube is used and each time the safe sampling volume of that tube is retested so that its
history can be monitored.  If a tube is repacked at any stage, the records should be amended accordingly.
January 1999        Compendium of Methods for Toxic Organic Air Pollutants           Page 17-21

-------
Method TO-17	VOCs

10.4 Pump Calibration and Tube Connection

   10.4.1  Tube Deployment
      10.4.1.1 Once at ambient temperature, remove the tubes from the storage container, uncap and connect
them to the monitoring pumps as quickly as possible using clean, non-outgassing flexible tubing.  Multi-bed
sorbent tubes must be orientated so that the air sample passes through the series of sorbents in order of increasing
sorbent strength (i.e., weaker sorbent first). This prevents contamination of the stronger adsorbent with less
volatile components.
      10.4.1.2 In all cases the sampling end of the tube must be clearly identified and recorded.
      10.4.1.3 A typical sampling configuration for a distributed volume pair of sampling tubes is shown in
Figure 4.
   10.4.2  Pump Calibration
      10.4.2.1  Pumps should be calibrated according to the manufacturer's instructions, preferably at the
monitoring location immediately before sampling begins or, alternatively, in a clean environment before the tubes
and pumps are transported to the monitoring site.  The apparatus required is described in Section 8.1.6. Details
of the pump flow rate delivered with a given identified tube and the flow rate, stroke rate or pressure selected on
the pump itself should be recorded together with the date.
      10.4.2.2 The pump flow rate should be retested at the end of each sampling period to make  sure that a
constant pump rate was maintained throughout the sample collection period.  The  flow rate measured at the end
of sampling should agree within 10% with that measured at the start of the sampling period for the sample to be
considered valid and the average value should be used.

10.5 Locating and Protecting the Sample Tube

The sampling points of individual sorbent tubes or sequential tube samplers should not be unduly influenced by
nearby emission sources unless the emission source itself is specifically being monitored.   Common sense
generally determines the appropriate placement.  Field notes on the relative location of known emission sources
should be part of the permanent record and identified on the FTDS. Some shelter or protection from high winds
(see Section 8.1.7) other extreme weather conditions and high levels of particulates is required for the sample tube
if it is to be left unattended during the monitoring period.

10.6 Selection of Pump Flow Rates and Air Sample Volumes

   10.6.1  Flow Rate Selection
      10.6.1.1  For 1/4 inch O.D. tubes, 50 mL/min is the theoretical optimum flow rate (31).  However,
negligible variation in retention volume will in fact be observed for pump flow rates varying  from 5 to
200 mL/min. Pump flow rates above 10 mL/min are generally used in order to minimize errors due to ingress
of VOCs via diffusion.  Flow rates in excess of 200 mL/min are not recommended for standard 1/4-inch sample
tubes unless for short term (e.g. 10 minute) monitoring (21).

[Note: High sampling flow rates can be used longer term for high boiling materials such as low level, vapor
phase polychlorinated biphenyls (PCBs) andpolycyclic aromatic hydrocarbons (PAHs) in air.]

      10.6.1.2  One and four liter air sample volumes are recommended  for this method if consistent with
anticipated safe sampling volumes.  Adjustments of the flow rates to accommodate low safe sampling volumes
should be made by proportionally reducing both rates with the qualification that the lower flow rate result is no
less than 300 mL total volume. The 300 mL sample gives adequate detection limits (<0.5 ppb per analyte) with
Page 17-22           Compendium of Methods for Toxic Organic Air Pollutants        January 1999

-------
VOCs	Method TO-17

full scan mass spectrometry detection for ambient air applications (see Table 4).  Sensitivity is generally enhanced
at least ten-fold if conventional GC detectors or selected ion monitoring are applied. However; the pump flow
rate, sampling time and consequently air volume  selected may be varied to suit the requirements of each
individual air monitoring exercise.
      10.6.1.3 Typical example pump flow rates include:

   •   16 mL/min to collect 1 L air samples in 1 hour
   •   67 mL/min to collect 4 L air samples in 1 hour
   •   10 mL/min to collect 1800 mL air samples over 3 hours
   •   40 mL/min to collect 7200 mL air samples over 3 hours

   10.6.2 Pump Flow Rate Selection
      10.6.2.1 The pump flow rate used is dependent upon:

   •   Safe sampling volume constraints. The flow  rate must be adjusted (within the allowed range) to ensure
      that, for the chosen sample collection time, SSVs are not exceeded for any target analyte
   •   Time weighted average monitoring requirements. If long-term -  3, 8 or even 24 hour - time weighted
      average  data are required, the pump flow rate must be adjusted to ensure SSVs are not exceeded during
      the sample collection period.
   •   GC detection limits. Within the constraints of safe sampling volumes and pump flow rate limits, air
      volumes selected for trace level (ambient) air monitoring, should be maximized  such that the largest
      possible analyte masses are collected.

      10.6.2.2 Typical VOC concentrations and the associated analyte masses retained from a range of different
air sample volumes in various atmospheres are presented in Table 4.

10.7 Sampling Procedure Verification - Use of Blanks, Distributed Volume Pairs, Back-Up Tubes, and
Distributed Volume Sets

   10.7.1 Field  and Laboratory Blanks
      10.7.1.1 Laboratory blanks must be identically packed tubes, from the same batch, with similar history
and conditioned at the same time as the tubes used for sample collection.  At least two are required per monitoring
exercise.  They must be stored in the laboratory in clean controlled conditions (<4°C) throughout the monitoring
program and analyzed at the same time as the samples- one at the beginning and one at the end of the sequence
of runs.
      10.7.1.2 Field blanks are the same as laboratory blanks except that they are transported to and from the
monitoring site,  are uncapped and immediately resealed at the monitoring site, but do not actually have air
pumped through them.  One field blank tube is taken for every  ten sampled tubes on a monitoring exercise and
no less than two field blanks should be collected, however small the monitoring study.  The field blanks should
be distributed evenly throughout the set of sampled tubes to be analyzed. Guidance on acceptable performance
criteria for blanks is given in Section 13.
   10.7.2 Distributed Volume Pairs
      10.7.2.1 When monitoring for specific analytes using a validated sorbent tube but in an uncharacterized
atmosphere, it is advisable to collect distributed volume tube pairs - e.g. 1 and 4 L samples - in parallel at every
monitoring location as described in Section 6. If single tube sampling is used to reduce analysis costs, a reduction
in the quality assurance associated with this method has to be assumed.
January 1999        Compendium of Methods for Toxic Organic Air Pollutants           Page 17-23

-------
Method TO-17	VOCs

      10.7.2.2  Back-up tubes (identical to those used for sample collection) should be used to investigate
situations in which distributed volume pairs do not agree within acceptable tolerance.  To use back-up tubes, a
second identical sampling tube is placed in series with a primary (front) tube.  The purpose of the backup tube
is to capture compounds that pass through the primary tube because of breakthrough. Analysis of the backup
tube may indicate unexpected breakthrough or give evidence of channeling of sample through the tube because
of loose packing.
      10.7.2.3 A significant volume of literature exists on the use of distributed volume sets to determine the
occurrence of nonlinearities when different sample volumes are taken from the same sample air mix. Ideally, the
quantity of material collected scales linearly with sample volume.  If this is not the case, then one of a number
of problems has occurred.  The 4-tube distributed volume developed by Walling, Bumgardner, and co-workers
(32,33) is a method by which sample collection problems can be investigated.

10.8 Determining and Validating Safe Sampling Volumes (SSV)

   10.8.1  Field Test Method for Tube Breakthrough.
      10.8.1.1  If SSV information is not readily available for the analytes under test on the sorbent tube
selected, or if the safe sampling volumes need validating - the following field experiment may be used. Link at
least 12 of the sorbent tubes under test together in series to give 6 pairs of tubes.  Use inert, preferably
Swagelok®-type  1/4-inch metal unions with PTFE fittings. The sampling end of the back up tube should be
connected to the exit end of the front tube in each of the pairs. The tube pairs are then connected to calibrated
monitoring pumps and used to simultaneously sample at least 3 different air volumes at pump flow rates between
10 and 200 mL/min with 2 replicates at each air sample volume.
      10.8.1.2 The experiment should be carried out in the atmosphere to be monitored and, if possible, under
worst-case conditions (i.e., highest natural humidity and highest typical VOC concentrations).  The sampling
points of all the tube pairs should be placed close together to ensure that, as far as possible, tubes are all sampling
the same atmosphere. The sampling location selected should be well ventilated. Both the front and back-up tubes
of each tube pair should subsequently be analyzed using thermal desorption - capillary GC.
      10.8.1.3 If more than 5% of one or more of the target analytes is observed on any of the back-up tubes,
breakthrough is shown to have occurred at that sample volume.  For practical purposes, the BV for a given
sorbent/analyte combination is usually considered to be the sample volume at which there is 5% breakthrough
of that analyte onto the back-up tube.  The SSV for that analyte/sorbent combination is then taken as two thirds
(-66%) of the BV.
   10.8.2  Chromatographic Test of Tube Retention Volume for Individual Analytes
      10.8.2.1  Inject 0.5 mg of each  analyte into a stoppered ~1L volume glass flask fitted  with a septum.
Check that all the analyte has evaporated.
      10.8.2.2 Connect the sample tube under test to a 1/4 inch injection port inside a GC oven. Use 530 ,um,
uncoated fused silica capillary tubing, or other appropriate narrow bore tubing, to connect the other end of the
sample tube to a FID detector. Use 1/4  inch fittings with graphite ferrules to connect to the sample tube itself.

      10.8.2.3 Set a nitrogen carrier gas flow of 50 mL/min through the tube.
      10.8.2.4 Inject a 0.1 mL sample of the vapor phase standard onto the tube using a gas syringe.  Adjust
the GC oven temperature so that the analyte peak elutes on the FID between 1 and 20 minutes.
      10.8.2.5 Repeat the experiment  4 or 5 times using different GC oven temperatures. Try to ensure that
at each of the GC temperatures selected, the peak elutes within 1-20 minutes.

[Note:   Use the  time from injection to peak crest as the  retention  time.  This may have to be  measured
manually, depending on the type of integrator available.]
Page 17-24           Compendium of Methods for Toxic Organic Air Pollutants         January 1999

-------
VOCs	Method TO-17

      10.8.2.6  Inject a sample of methane to measure the delay time of the system and subtract this from the
analyte retention times determined.
      10.8.2.7Use the flow of nitrogen carrier gas and corrected retention times to calculate the analyte retention
volumes at different sorbent temperatures.
      10.8.2.8 A graph of Iog10 retention volume vs. l/temp(K) should produce a straight line plot which can
be readily extrapolated to ambient temperatures. Use this plot to obtain the retention volume.

A SSV for the analyte on that sorbent tube is then derived by halving the calculated retention volume at ambient
temperature.  When required, this experiment should be carried out for the least well retained compound(s) of
interest.

10.9 Resealing Sorbent Tubes After Sample Collection

Sampled tubes should be recapped with the metal, Swagelok®-type caps and combined PTFE ferrules, rewrapped
in the aluminum foil (if appropriate) and replaced in the storage container immediately after sampling.  They
should not be removed from the sampling container until they are in the laboratory and about to be analyzed.

10.10 Sample Storage

Samples should be refrigerated at <4°C  in a clean environment during storage and analyzed within 30 days of
sample collection (within one week for limonene, carene, fe-chloromethyl ether and labile sulfur or nitrogen-
containing volatiles). Samples taken on  tubes containing multiple sorbent beds should be analyzed as soon as
possible after sampling unless it is know in advance that storage will not cause significant sample recovery errors
(see also Section 7.1.3 concerning artifacts).
11. Analytical Procedure

11.1 Preparation for Sample Analysis

Follow the description given in Compendium Method TO-15 for  set up of the GC/MS analytical system
including column selection, MS tune requirements, calibration protocols, etc.

11.2 Predesorption System Checks and Procedures

The following sample and system integrity checks and procedures must be carried out manually or automatically
before thermal desorption:

   •  Dry purge.  Dry purge the batch of sampled, back-up and field blank tubes (do not purge lab blanks).
   •  Cap.  Cap tubes with PTFE 'analytical' caps and place on instrument carousel.
   •  Leak test the tubes. Each tube must be stringently leak tested at the GC carrier gas pressure, without heat
      or gas flow applied, before analysis.  Tubes which fail the leak test should not be analyzed, but should be
      resealed and stored intact. On automated systems, the instrument should continue to leak test and analyze
      subsequent tubes after a given tube has failed.  Automated systems should also store a record of which
      tubes in a sequence have failed the leak test in battery-protected system memory until the error  is
      acknowledged by an operator. These measures prevent sample losses and help ensure data quality.
January 1999        Compendium of Methods for Toxic Organic Air Pollutants          Page 17-25

-------
Method TO-17	VOCs

   •  Leak test the sample flow path.  All parts of the sample flow path should be stringently leak tested
      before each analysis without heat or gas flow applied to the sample tube.  An automatic sequence of tube
      desorptions and GC analyses should be halted if any leak is detected in the main sample flow path.
   •  Purge air.  Purge air from the tube and sample flow path at ambient temperature using carrier gas
      immediately before tube desorption. It helps to dry the sample and prevents analyte and sorbent oxidation
      thus minimizing artifact formation, ensuring data quality and extending tube lifetimes. The focusing trap
      should be in-line throughout the carrier gas purge to retain any ultra-volatile analytes "desorbed" from the
      tube prematurely.
   •  Check GC/MS analytical system ready status.   The "ready" status of the GC, detector(s), data
      processor and all parts of the analytical system should be automatically checked by the thermal desorption
      device before each tube desorption.  It should not be possible to desorb a tube into the analytical system
      if it is not ready to accept and analyze samples.
   •  Internal standard. Introduce a gas phase internal standard onto the sorbent tube or focusing trap before
      primary (tube) desorption, as an additional check of system integrity (optional).

A series of schematics illustrating these steps is presented in Figure 3, Steps (a) through (f).

11.3 Analytical Procedure

   11.3.1  Steps Required for Reliable Thermal Desorption.
      11.3.1.1  A stepwise summary of the complete thermal desorption procedure is as follows:

   •  Predesorption system checks (see Section 11.2).
   •  Introduction of a fixed volume gas phase internal standard (optional) [see Figure 3,  Step (d)].
   •  Desorption of the sorbent tube (typically 200-300°C for 5-15 minutes with a carrier gas flow of 30-100
      mL/min - see Table 2) and refocusing of the target analytes on a focusing trap held at near- ambient or
      subambient temperatures [see Figure 3, Step (e)].

[Note: Analytes should be desorbed from the tube in Tbackflush " mode, i. e., with the gas flow in the reverse
direction to that of the airflow  during sampling].

   •  Splitting the sample as it is transferred from the tube to the focusing trap (Optional). This is only required
      to prevent column or detector overload due to excess water accumulation or during the analysis of high
      concentration/large volume air samples or when using ultra-sensitive detectors such as the BCD [see
      Figure 3, Step (e)].
   •  Rapid desorption of the focusing trap (typically 40 deg/sec. to a top temperature of 250-350°C, with a
      ?hold" time of 1-15 mins at the top temperature and an inert/carrier gas flow of 3-100 mL/min) and
      transfer of the analytes into the analytical column [see Figure 3, Step (f)].

[Note:  Components should normally be desorbed from the focusing trap in Tbackflush "  mode, i.e., with the
gas flow through the 'cold' trap in the reverse direction to that used during analyte focusing.]

   •  Splitting the sample as VOCs are transferred from the focusing trap to the analytical column. (Optional).
      This is only required to prevent column or detector overload due to excess water accumulation or during
      the analysis of high concentration/large volume air samples or when using ultra-sensitive detectors such
      as the BCD [See Figure 3, Step (f)].
   •  Desorbing the focusing trap initiates the GC run. [See Figure 3, Step (f)].
Page 17-26           Compendium of Methods for Toxic Organic Air Pollutants         January 1999

-------
VOCs	Method TO-17

   •  All volatiles should be stripped from the sorbent tubes during the thermal desorption process leaving them
      clean and ready for reuse.  The tubes should be resealed to ensure they are kept clean and ready for
      immediate reuse while the sequence of tube desorptions and analyses is completed.
   11.3.2 GC/MS Analytical Procedure
      11.3.2.1 Once the GC run has been initiated by desorption of the focusing trap, the chromatographic
procedure continues as described in Compendium Method TO-15.
      11.3.2.2 The precision of the analytical system should be tested using six standard tubes all loaded with
a mid-concentration-range standard.  This procedure should be carried out whenever the thermal desorption -
GC/MS analytical method is changed and should be repeated once every tenth series of samples run with an
analytical method or once every three months, whichever happens first.  The report produced from the most recent
precision test should be included with the final batch report generated for each series of samples.
12. Calibration of Response

Descriptions of how to load tubes from standard atmospheres, concentrated gas phase standards or liquid
standards are given in Sections 9.2 and 9.3.  Once the tubes are desorbed to the focusing trap and into the
analytical GC/MS system the calibration procedure  becomes identical to  that presented in Section 3 of
Compendium Method TO-15.  The guidance given in Section 3 of Compendium Method TO-15 concerning
multi-level calibration procedures and calibration frequencies should be followed for this Compendium method.
It is also advisable to analyze a single level calibrant (i.e. tubes loaded with analyte masses in the mid-range of
those expected to be collected during sampling) approximately every tenth sample during an analytical sequence,
as a check on system performance. All samples processed that exceed the calibration range will require data
qualifiers to be attached to the analytical results.
13. Quality Assurance

13.1 Validating the Sample Collection Procedure

   13.1.1  Blanks.

      13.1.1.1 Artifact levels on laboratory and field blanks should be at the low or sub-nanogram level for
carbonaceous sorbents and Tenax® and at the double digit ng level for Porapaks®, Chromosorb® Century series
sorbents and other porous polymers as described in Section 7.1.  If artifact levels are considerably above this,
careful attention must be paid to the tube conditioning and storage procedures described in Sections 10.2.1 and
10.2.2. Artifact peaks which are 10% or more of the area of average component peaks should be marked as
artifacts in the final data reports.  When monitoring unknown atmospheres, special care must be taken to
distinguish between sorbent artifacts and analytes, using the MS to identify components which are significant in
both blank and sampled tubes.
      13.1.1.2 If the same profile/pattern of VOCs is observed on the field blanks as on the sampled tubes and
if the level of these components is 5%  or more of the sampled volatiles, careful attention must be paid to the
method of sealing the tubes and other storage procedures in future studies. If the profile of volatiles on the field
blanks matches that of the sampled tubes and if the areas of the peaks on the field blank are 10% or more of
sampled tube levels, the sampled tube data are invalidated.
January 1999         Compendium of Methods for Toxic Organic Air Pollutants           Page 17-27

-------
Method TO-17	VOCs

   13.1.2  Routine Checking of Sorbent Tube Safe Sampling Volumes.
      13.1.2.1 The SSVs of sorbent tubes should be retested annually or once every 20 uses (whichever happens
first) using one of the procedures described in Section 10.8.
      13.1.2.2 If the SSV of a tube (i.e., half the RV or two thirds of the BV) falls below the normal air sample
collection  volume for the analytes in question, the tube should be repacked with fresh  adsorbent and
reconditioned.

13.2 Performance Criteria for the Monitoring Pump

Records of the pump flow rate delivered against the pump flow rate, stroke rate or pressure selected on a pump
should be reviewed at least  once per three months.  If the performance of any pump has been found to have
changed significantly over that time; for example if completely different pump settings are required to deliver the
same pump flow rate, the pump should be serviced by the manufacturer or their approved agent.

Sampling pump errors can normally be presumed to be in the order of 5% (8). If the pump sampling flow rate
measured at the end of sample collection varies more than 10% from that measured at the beginning of sample
collection, then that sample is invalidated.
14. Performance Criteria for the Solid Adsorbent Sampling of Ambient Air

14.1 Introduction

There are four performance criteria which must be met for a system to qualify under Compendium Method TO-
17.  These criteria closely parallel those of Compendium Method TO-15, "The Determination of Volatile
Organic Compounds (VOCs)  in Air Collected in Specially Prepared  Canisters and Analyzed by Gas
Chromatography/Mass Spectrometry (GC/MS) ". These criteria are:

   •  A method detection limit < 0.5 ppb.
   •  Duplicate (analytical) precision within 20% on synthetic samples of a given target gas or vapor in a typical
      target gas or vapor mix in humidified zero air.
   •  Agreement within 25% for distributed volume pairs of tubes taken in each sampling set.
   •  Audit accuracy within 30 percent for concentrations normally expected in contaminated ambient air (0.5
      to 25 ppb). Either mass spectrometry as emphasized here, or specific detectors can be used for analysis.
      Details for the determination of each of the criteria follow.

14.2 Method Detection Limit

The procedure  chosen to define the method detection limit is that given in the Code of Federal Regulations
(40CFR136  Appendix B).  The method detection limit is defined for each system by making seven replicate
measurements of a concentration of the compound of interest near the expected detection limit (within a factor
of five), computing the standard deviation for the seven replicate concentrations, and multiplying this value by
3.14 (the Student's t value for 99 percent confidence for seven values).
Page 17-28           Compendium of Methods for Toxic Organic Air Pollutants        January 1999

-------
VOCs	Method TO-17

14.3 Analytical Precision of Duplicate Pairs

The measure of analytical precision used for this method is the absolute value of the relative difference between
two identical samples (same flow rate over the same time period from with a common inlet to the sample volume).
The analytical precision is expressed as a percentage as follows:

                             Analytical Precision  =   [IX1 " X2I] |  100


where:
       XI =  A measurement value taken from one of the two tubes using in sampling.
       X2 =  A measurement value taken from the second of two tubes using in sampling.
        X =  Average of XI and X2.

The analytical precision is a measure of the precision achievable for the entire sampling and analysis procedure
including the sampling and thermal desorption process mentioned above and the analytical procedure that is same
as the TO-15  analytical finish, although specific detector systems can also be used.

14.4 Precision  for the Distributed Volume Pair

The measure  of precision used for this method is the absolute value of the relative difference between the
distributed volume pair expressed as a percentage as follows:
                              percent difference = I  -^	31  100
                                                 (      X      '

where:
        XI = One measurement value (e.g., for a defined sample volume of 1 L).
        X2 = Duplicate measurement value (e.g., for a defined sample volume of 4 L taken over the same time
              period as the first sample).
          X = Average of the two values.

There are several factors that may affect the precision of the measurement as defined above.  In fact any factor
that is nonlinear with sample volume may be significant enough to violate the constraint placed on distributed
volume pair precision.  These  factors include artifact formation, compound reactions on the sorbent, breakthrough
of target compounds,  etc.

14.5 Audit Accuracy

A measure of audit accuracy is the degree of agreement with audit standards. Audit accuracy is defined as the
relative difference between the measurement result and the nominal concentration of the audit compound:
                   Audit Accuracy, % =
                                       (Spiked Value  - Observed Value)
                                                (Spiked Value)

The choice of audit standard is left to the analyst.
x 100
January 1999        Compendium of Methods for Toxic Organic Air Pollutants           Page 17-29

-------
Method TO-17                                                                           VOCs
15. References

 1.  Riggin, R M., Compendium of Methods for the Determination of Toxic Organic Compounds in Ambient
    Air: Methods TO-1 andTO-2, U. S. Environmental Protection Agency, Research Triangle Park, NC 27711,
    EPA 600/4-84-041, April 1984.

 2.  Winberry, W. T. Jr., et al., Compendium of Methods for the Determination of Toxic Organic Compounds
    in Ambient Air: Method TO-14, Second Supplement, U. S. Environmental Protection Agency, Research
    Triangle Park, NC 27711, EPA 600/4-89-018, March 1989.

 3.  Schmidbauer, N., and Oehme, M., "Comparison of Solid Adsorbent and Stainless Steel Canister Sampling
    for Very Low ppt-concentrations of Aromatic Compounds (>C6) in Ambient Air From Remote Areas,"
    Fresenius ZAnal. Chem., 331, pp 14-19, 1988.

 4.  Ciccioli, P., Brancaleoni, E., Cecinato, A., Sparapini, R, and Frattoni, M., "Identification and Determination
    of Biogenic and Anthropogenic VOCs in Forest Areas of Northern and Southern Europe and a Remote Site
    of the Himalaya Region by High-resolution GC-MS," J. ofChrom., 643, pp 55-69, 1993.

 5.  Hafkenscheid, T., Peters, R, NMI, The Netherlands, Private Communications to E. Woolfenden of Perkin
    Elmer Corp., Norwalk, Conn.

 6.  Ciccioli, P., Brancaleoni, E., Cecinato, A., DiPalo, C., Brachetti, A., and Liberti, A., "GC Evaluation of the
    Organic Components Present in the Atmosphere at Trace Levels with the Aid of Carbopack™ B for
    Preconcentration of the Sample," J.ofChrom., 351, pp 433-449, 1986.

 7.  MDHS 72 (Volatile Organic Compounds in Air), "Laboratory Method Using Pumped Solid Sorbent Tubes,
    Thermal Desorption and Gas Chromatography," Methods for the Determination of Hazardous Substances
    (MDHS), UK Health and Safety Executive, Sheffield, UK.

 8.  Vandendriessche, S., and Griepink, B., "The Certification of Benzene, Toluene and m-Xylene Sorbed on
    Tenax TA in Tubes," CRM-112 CEC, BCR, EUR12308 EN, 1989.

 9.  Lindquist, F., and Balkeren,  H., "Stability of Chlorinated Hydrocarbons on Tenax," CEC Commissioned
    Report From TNO, The Netherlands, Rpt.  No. R90/268, 1990.

10. Bianchi, A. P., and Varney, M. S., "Sampling and Analysis of VOCs in Estuarine Air by GC-MS," J. of
    Chrom.,643,pp 11-23, 1993.

11. Tipler,  A.,  "Water  Management  in Capillary Gas Chromatographic Air  Monitoring Systems," in
    Proceedings  of the Air and Waste Management Association Conference: Measurement of Toxic and
    Related Air Pollutants, Air and Waste Management Association, Pittsburgh, PA, May 1994.
Page 17-30           Compendium of Methods for Toxic Organic Air Pollutants        January 1999

-------
VOCs	Method TO-17

12.  Helmig, D. and Vierling, L., "Water Adsorption Capacity of the Solid Adsorbents Tenax TA, Tenax GR,
    Carbotrap, Carbotrap™ C, Carbosieve™ SIII and Carboxen™ 569 and Water Management Techniques
    for the Atmospheric Sampling of Volatile Organic Trace Gases,"  Anal.  Chem.,  Vol.  67, No 23,
    pp 4380-4386, 1995.

13.  McClenny, W. A., Oliver, K. D. and Daughtrey, E. H., Jr. "Analysis of VOCs in Ambient Air Using
    Multisorbent Packings for VOC Accumulation and Sample Drying," J. Air and Waste Management Assoc.,
    Vol 45, pp 792-800, 1995.

14.  Pankow, J. G., "Technique for Removing Water from Moist Headspace and Purge  Gases  Containing
    Volatile Organic Compounds:  Application in the Purge with Whole-column Cryotrapping (P/WCC)
    Method," Environ. Sci. Technol.,Vo\25,pp 123-126, 1991.

15.  Harper, M., "Evaluation of Solid Sorbent Sampling Methods by Breakthrough Volume Studies," Ann.
    Occup. Hyg., pp 65-88, 1993.

16.  Pollack, A. J., Gordon, S. M., Moschandreas, D. J., McClenny, W. A., and Mulik, J. D., "Evaluation of
    Portable Multisorbent Air Samplers for Use with an Automated Multitube Analyzer." Project Rpt by
    Battelle Columbus Operations for U. S. Environmental Protection Agency, Contract No. 68-DO-0007,
    Sept 1992.

17.  Broadway, G. M., and Trewern, T., "Design Considerations for the Optimization of a Packed Thermal
    Desorption Cold Trap for Capillary Gas Chromatography," Proc. 13th Int'l Symposium on Capil. Chrom.,
    Baltimore, MD, pp 310-320, 1991.

18.  Broadway, G. M., "An Automated System for use Without Liquid Cryogen for the Determination of VOC's
    in Ambient Air," Proc. 14th Int'l. Symposium on Capil. Chrom., Baltimore, MD, 1992.

19.  Gibitch, J., Ogle, L., and Radenheimer, P., "Analysis of Ozone Precursor Compounds in Houston, Texas
    Using Automated Continuous GCs," in Proceedings of the Air and  Waste Management Association
    Conference: Measurement of Toxic and Related Air Pollutants, Air and Waste Management Association,
    Pittsburgh, PA, May 1995.

20.  MDHS 2 (Acrylonitrile in Air), "Laboratory Method Using Porous Polymer Adsorption Tubes, and Thermal
    Desorption with Gas Chromatographic Analysis," Methods for  the Determination  of Hazardous
    Substances (MDHS), UK Health and Safety Executive, Sheffield, UK.

21.  MDHS 22 (Benzene in Air), "Laboratory Method Using Porous Polymer Adsorbent Tubes, Thermal
    Desorption and Gas Chromatography," Method for the Determination of Hazardous Substances (MDHS),
    UK Health and Safety Executive, Sheffield, UK.

22.  MDHS 23 (Glycol Ether and Glycol Acetate Vapors in Air), "Laboratory Method Using Tenax Sorbent
    Tubes,  Thermal Desorption and Gas Chromatography,"  Method for the Determination of Hazardous
    Substances (MDHS), UK Health and Safety Executive, Sheffield, UK.
January 1999        Compendium of Methods for Toxic Organic Air Pollutants           Page 17-31

-------
Method TO-17	VOCs

23.  MDHS 40 (Toluene in air), "Laboratory Method Using Pumped Porous Polymer Adsorbent Tubes, Thermal
    Desorption and Gas Chromatography," Method for the Determination of Hazardous Substances (MDHS),
    UK Health and Safety Executive, Sheffield, UK.

24.  MDHS 60 (Mixed Hydrocarbons (C3 to C10) in Air), "Laboratory Method Using Pumped Porous Polymer
    and Carbon Sorbent Tubes, Thermal Desorption and Gas Chromatography," Method for the Determination
    of Hazardous Substances (MDHS), UK Health and Safety Executive, Sheffield, UK.

25.  Price, J. A., and Saunders, K. J., "Determination of Airborne Methyl Tert-butyl Ether in Gasoline
    Atmospheres," Analyst, Vol. 109, pp. 829-834, July 1984.

26.  Coker, D. T., van den Hoed, N., Saunders, K. J., and Tindle, P. E., "A Monitoring Method for Gasoline
    Vapour Giving Detailed Composition," Ann.  Occup, Hyg., Vol 33, No. 11, pp 15-26, 1989.

27.  DFG,  "Analytische  Methoden  zur  prufmg  gesundheitsschadlicher  Arbeistsstoffe,"   Deutsche
    Forschungsgemeinschaft, Verlag Chemie, Weinheim FRG, 1985.

28.  NNI, "Methods in NVN Series (Luchtkwaliteit; Werkplekatmasfeer)," Nederlands Normailsatie - Institut,
    Delft, The Netherlands, 1986-88.

29.  "Sampling by Solid Adsorption Techniques," Standards Association of Australia Organic Vapours,
    Australian Standard 2976, 1987.

30.  Woolfenden, E. A., "Monitoring VOCs in Air Using Pumped Sampling onto Sorbent Tubes Followed by
    Thermal Desorption-capillary  GC  Analysis: Summary of Reported Data and Practical Guidelines for
    Successful Application," J. Air and Waste Management Assoc., Vol. 47, 1997, pp. 20-36.

31.  Brown, R H., and Purnell, C. J., "Collection and Analysis of Trace Organic Vapour Pollutants in Ambient
    Atmospheres: The Performance of a Tenax-GC Adsorbent Tube," J. ofChrom., Vol 178, pp 79-90, 1979.

32.  Walling,  J. F., "The Utility of Distributed Air Volume Sets When Sampling Ambient Air Using Solid
    Adsorbents," Atmos. Environ., Vol 18, No 4, 855-859, 1984.

33.  Walling, J. F., Berkley, R. E., Swanson, D. H. and Toth, F. J., "Sampling Air for Gaseous Organic Chemical
    Using Solid Adsorbents: Application to Tenax," U. S. Environmental Protection Agency, Research Triangle
    Park, NC 27711, EPA 600/5-82-059, May 1982.
Page 17-32           Compendium of Methods for Toxic Organic Air Pollutants        January 1999

-------
VOCs
                                                       Method TO-17










RBENT SELECTION
O
O
fe
w

Q
w
Q
^
O



w
I-J
•

c/5
T3

rt
latics except benzene, Apolar components (bp>100°C)
onents(bp>150°C).
o S
5 o
< 0


m







O

en


O
§^
^
0 C
OS
od
0 jl.
a



g

H



H


a
H

<2
benzenes, vapor phase PAHs and PCBs and as above :
f


i/-i







o

m


O
O c
3d
0 C
OS
od
a



naxGR

H

„
rt C
If
p"2

in 3
A *-^

XI OH
range of VOCs inc., ketones, alcohols, and aldehydes I
r compounds within the volatility range specified. Plus
• gases.
-gJ2 S


0

^





o
o



o"
c
p
d1
o*
-S-



rbotrap®
rbopackB®
asorb® GCB 1

00<


«
"
S
o
_o

J3
-o
a wide range of VOCs incl. oxygenated compounds an
le than methylene chloride.
'3"o
1X1 >


o

en





o




o

t"-





o

(N


O
o
o
(N
O
o
OH




romosorb 106
J3
O









-ri
a wide range of VOCs including oxygenated compouni
1X1


o

i/-i





o

 ^
^



1

&H
,2
'S
o
'S,
1
T3
a
cS
' — i
'-5 °
'<-H "^
fically selected for volatile nitriles; acrylonitrile, acetoi
good for pyridine, volatile alcohols from EtOH, MEK,
'3 o
D «


0

m





^

rt


O
f^cj
^ i
oS
IO JJH
GH




|

&H

O
ffi
o
T3

1X1
O
u~
T3

for very volatile compounds such as VCM, ethylene o
good for volatile polars e.g. MeOH, EtOH and acetone
II


o
o






o

•*


Q

»n i
O *^





tierocarb*
P

S

_o

• r^

"o
^
«"
C
for ultra volatile compounds such as C C hydrocarbc
-eons.
li




00







^1-


O
o
OO
O
S



®ffil..
rbosieve SIII*'
rboxen 1000*5
asorb® CMS*

00<










specifically for 1,3- butadiene and nitrous oxide.
-a










o

en


O
o
OO
o
O
S

*
*
X
2
3lite
tlecular Sieve

N2

_u o
^ o
111
D C O


"3-^2
o'"--

fcwj ^
y used for thermal desorption because metal content m;
dation. Petroleum charcoal and Anasorb® 747 are use
irtion in the EPA's volatile organic sampling train (VOi
fa 00 cr?T3
« u u a
fX-o-o 3


o
o

A




o

•*


O
o

O



«
* ^
conut Charcoa
3conut charcoE
ely used)
°O 'S

                                                                         C
                                                                         W
                                                                         II
                                                                         12
                                                                      3 3 © £
                                                                        OH X V

                                                                        »  ta
                                                                       -H  —i
                                                                       o o-^

                                                                      "o 
-------
Method TO-17
                                                               VOCs





















w
^3
H
Iz;
^-H
UJ

2

O

O
fc
oo
W
g
, T
w
Q


O
(N
w

m


E"1
















oo
•j2
o
03
PH
O.
g
H
00
'S
^
o
13
u
c
1
g
o
o
u
erf


2 G
(S.|

•^S 0
^H O



OH ^

G Q
Hfe

S-4
O
V4
^
_o
C/5
03
-rt -^
C S
=3.2

S O
HO


^


^"°
O.
g
'S &
E2




-g
0
o
ja
H
"3.
03









©
O
^
03
OH
O3
O
S-H
o
©
X
03
G
u
H

C
|
S
o
ro
T3
G
03
O
0
in
rn

C
"S
-$*
"g
o
0
T3
C
03
O
0
in



c/5
u


0
o
A






^

0








laxGR
D
H









©
m
^
O
cj
OH
O
^
rt
o
o
X
03
G
u
H

C
|
S
o
CO
T3
G
03
O
0
in
rn

C
"S
-$*
"g
o
0
T3
C
03
O
0
in



c/5
u


0
o
A






m
•botrap®
•bopackB®
asorb® GC
03 03 C
oo<;

CN
O
E
o
^
O
0
o.
03
VI

O
c/5
"3.
m
o
"8
x>


Q

c
6
g
o
CO
T3
C
03
O
0
m


C
"S
~5
"g
o
0
T3
C
03
O
0



c/5

>^

0
in







o
romosorb®

O

yD
o
E
o
^
O
0
o.
-§
W2
2
O
c/5
_3
"3.
m
o
u
x>


Q

c
|
S
o
CO
T3
G
03
O
0
O
in

C
"S
-^
"g
o
0
T3
C
03
O
0
in



c/5
u


0
in







y3
o
romosorb 1

O


cx
"a
03
O
PH
0
O.
03
VI

O
c/5
"3.
m
o
1


Q

c
'g
6
o
CO
T3
C
03
O
0
m


C
"S
•~5
"g
o
0
T3

03
O
0
in



c/5
u


0
in








CX
a
o
PH


^
a
s
o
PH
0
O.
VI
2
O
c/5
"3.
m
o
u


Q

G
|
S
O
CO
T3
C
03
O
0
O
00

g
'S
c
1=
o
0
T3
C
03
O
1



M
0


g








a
s
o
PH

o
03
O
0
J3
O.

0
O.
03
M
^
O
c/5
"3.
m
o
"8
x>


Q

c
6
g
o
CO
T3
C
03
O
0
O
ON

C
"S
~5
1=
o
0
T3
C
03
O
8





^

0
o
A







lerocarb*
0



G
_0
"o3
VI

O
0
OH
Vt
^
O
c/5
"3n
m
O
u


Q

c
|
S
o
CO
T3
G
03
O
0
in
rn

C
"S
-^
1=
o
0
T3
C
03
O
0
in





£

8






©
*

S|o
C/5 X b?
S ol C
oo<;


c
_0
"03
H

O
0
OH
Vt
21
O
c/5
"3n
m
O
u


Q

G
|
S
O
CO
T3
C
03
O
0
O
O

C
"S
-**_
"g
o
0
T3
C
03
O
0





£

0






*
*
CO
o
:>
)lite
ilecular Sie'
53 'fi
Kj5j
















X
03
G
u
H

C
|
S
o
co
T3
G
03
O
0
O
O

C
"S
-$*
1=
o
0
T3
C
03
O
0



c/5
u


0
in






3
H
0
o
C OH Q
HHc/3








OH
03
M
g;
O
c/5
"3n
m
O
"8
jz


Q

c
|
g
o
CO
T3
C
03
O
0
m


C
"3
-$*
1=
o
0
T3
C
03
O
0
in





> H
OH&O








OH
03
VI
2;
o
c/5
"3n
m
O
1


Q

c
'g
6
o
co
T3
C
03
O
0
in


C
"S
-5
1=
o
0
T3

03
O
0
in




2,
£

8






6
80
O >v-i
rt -3 8
OHoo

§"
M
^
^
w

_>> "°
-5 • "i^
'§8 g§
3 ° u'-P
^ OH T3 03
> OH -t3 OH
'-g 00 * o
•fj.S .20
"" o © 2
C-^-ta x u
o-- G S-g
8 g S^
^u ^'o
00^ C/}1^

o - E
,fo 5"g
1*0 ° *
CU .2 M
O3 i-j 0} --H
<^W gtg)
O-^1 M"o3
1—1 § *° §"
o o So

O OH c3

"^ o So"

cj g g „
O J^ - — i ^
C T-* rxs
T3 C cj 00
0 S> O^H
O g S-H o
-^ Q ^J
o> c H =3
1-1 o l~~l S
^O M ^ Q Cj

oj '^ .|t


0> c/5 O ^ ©
g U JU °=XJ
3 u O ^ g
•-* M T3 O3 CH

C C --H H
•S,ta g g o,
g_>, ^ X g


"•g ^ S u
^5 t? "-|

|| o "si
^ o * s"_§
go m ^ 03
C ^ ^ c/1
O o o Q '^
M_3 03 03 fc?)
*^" OH OH*<
If 111
|l^ H|
^^ C OQ
|.§) 5 "f'-s
^oo O O i— i
*
* *
Page 17-34
Compendium of Methods for Toxic Organic Air Pollutants
January 1999

-------
VOCs
                                                            Method TO-17
        TABLE 3 - LIST OF COMPOUNDS WITH BREAKTHROUGH VOLUMES >5L USING
             THE AIR TOXICS TUBE STYLE 2 LISTED IN SECTIONS 6.1.2 AND 9.1.3
                              OF COMPENDIUM METHOD TO-17
[Note: The following list of compounds was determined to have breakthrough volumes of greater than 5 liters
of trace levels in humidified zero air for humidities of 20%,  65% and 90% RH at 25° C.  The tests were
performed immediately prior to the publication of this document at the Research Triangle Institute, Research
Triangle Park, NC as a result of activities leading up to the publication of this document.  Compounds with
an * were not tested at 90% RH.]
 Halocarbon 114
 1,3,5 -Trimethylbenzene
 Halocarbon 11
 1,2,4-Trimethylbenzene
 Halocarbon 113
 Dichlorobenzenes
 1,1 -Dichloroethene
 1,2,4-Trichlorobenzene
 Methylene Chloride
 Hexachloro-1,3 ,-butadiene
 1,1 Dichloroethane
*1,3 Butadiene
 cis- 1,2-Dichloroethene
*Acetonitrile
 Chloroform
*Acetone
 1,1,1 -Trichloroethane
*2-Propanol
 Carbon tetrachloride
*Acrylonitrile
 Benzene
*Isoprene
                               1,2-Dichloroethane
                              *Methyl Acetate
                               Trichloroethene
                              *Methyl tert-Butyl Ether
                               1,2-Dichloropropane
                              *Methyl Ethyl Ketone
                               cis- 1,3-Dichloropropene
                              *Ethyl Acrylate
                               Toluene
                              *Methyl Acrylate
                               Trans-1,3-Dichloropropene
                              * Methyl Isobutyl Ketone
                              "Furfural
                               Tetrachloroethene
                               1,2-Dibromoethane
                               Chlorobenzene
                               Ethylbenzene
                               m-Xylene
                               p-Xylene
                               o-Xylene
                               1,1,2,2-Tetrachloroethane
January 1999
Compendium of Methods for Toxic Organic Air Pollutants
Page 17-35

-------
Method TO-17
                                                        VOCs
   TABLE 4. MASS OF AN ANALYTE 'X' COLLECTED FROM 1, 2 OR 10 L AIR SAMPLES AT
                   DIFFERENT ATMOSPHERIC CONCENTRATIONS
                   (ASSUMING 'X' HAS A MOLAR WEIGHT OF 100 g)
Sample type
Fenceline/severe urban area
Indoor air sampling
Avg. exposure to benzene
Normal urban area
Normal rural area
Forested area
Mt. Everest/K2 site
Arctic on an ultraclean day
Typical
concentration
1 0-250 ppb
1-100 ppb
~3ppb
1-10 ppb
0.1-1 ppb
0.25-2.5 ppb
0.025-7. 5 ppb
15-50ppt
Mass collected in
1 L sample volume
40-1, 000 ng
4-400 ng
ling
4-40 ng
0.4-4 ng
1-10 ng
0.1-30ng
60-200 pg
Mass collected in
2 L sample volume
80 ng-2 [j.g
8-800 ng
22 ng
8-80 ng
0.8-8 ng
2-20 ng
0.2-60 ng
0. 12-0.4 ng
Mass collected in 10
L sample volume
OA-lO[j.g
40 ng-4//g
HOng
40-400 ng
4-40 ng
10-100 ng
l-300ng
0.6-2 ng
Page 17-36
Compendium of Methods for Toxic Organic Air Pollutants
January 1999

-------
VOCs
                                                   Method TO-17
                          COMPENDIUM METHOD TO-17
                         FIELD TEST DATA SHEET (FTDS)
   I. GENERAL INFORMATION
      PROJECT:.
      SITE:	
      LOCATION:	
      INSTRUMENT MODEL NO.:.
      PUMP SERIAL NO.:	
                       DATE(S) SAMPLED:	
                       TIME PERIOD SAMPLED:.
                       OPERATOR:	
                       CALIBRATED BY:.
                       RAIN:	YES
NO
      ADSORBENT CARTRIDGE INFORMATION:

               Tube 1        Tube 2
       Type:
   Adsorbent:
    Serial No.:
   Sample No.:
   II. SAMPLING DATA
Tube
Identifi-
cation






Sampling
Location






Ambient
Temp.,
°F






Ambient
Pressure,
inHg






Flow Rate (Q),
mL/min
Tubel






Tube 2






Sampling Period
Start






Stop






Total
Sampling
Time,
min.






Total
Sample
Volume,
L






   III. FIELD AUDIT
                            Tube 1     Tube 2
      Audit Flow Check Within  _        _
       10% of Set Point (Y/N)?     pre-       pre-
                            post-
                    post-
      CHECKED BY:.
      DATE:	
                 Figure 1. Compendium Method TO-17 Field Test Data Sheet.
January 1999
Compendium of Methods for Toxic Organic Air Pollutants
             Page 17-37

-------
Method TO-17
                                                                                 VOCs
                  Stainless steel tube:
                  Total volume: - 3 mL
                  Sorbent capacity: 200 - 1000 mg
                                                                   Adsorbent
                                                                   bed(s)
                                                           Stainless steel
                                                           gauze (- 100 mesh}
                     15 mm
      Pump flow   •*	*••*
      Desorb flow
                                               Maximum 60 mm
                                                                                  Minimum 15 mm



'Z:
5 mm I.D.
T% inch
j(~6 mm)O.D.
                                               3.5 inch (-89 mm)
                                   Stainless steel
                                   gauze (-100 mesh)
                                          Stainless
                                          steel tube
     Stainless steel
     gauze retaining spring
                  Glass tube:
                  Total volume: ~ 2 ml
                  Sorbent capacity: 130 - 650 mg
                                                                   Adsorbent
                                                                   bed(s)
                     15 mm
                                               Maximum 60 mm
      Pump flow
      Desorb flow
                                              3.5 inch (-89 mm)
                                  ' Unsilanized
                                   glass wool
                                           Glass
                                           tube
                                                                                  Minimum 15 mm
' Unsilanized
 glass wool
                Figure 2.  Example of construction of commercially available adsorbent tubes.
Page 17-38
Compendium of Methods for Toxic Organic Air Pollutants         January 1999

-------
VOCs
                                                                   Method TO-17
Inlet split
vent closed
Sorbenttubeat
ambient temp. j

.— — .— -i pyi.
Carrier gas Pressure Desorl
supply closed transducer vent c
r
bflow
losed
Cool sorbent trap
TTV
Carrier V /
gas in \^ ./
GC analytical
column
        (a) Tube leak check.
                               Inlet split
                              vent closed
Sorbent tube at
ambient temp.
                                       Cool sorbent trap
       Carrier gas
      supply closed
              Pressure
             transducer
                                            Desorb flow,
                                            vent closed
                                                       Carrier
                                                       gas in
        (b) Leak check sample flow path.
                                                                                   Detector
GC analytical
  column
     Figure 3.  Sequence of operations to thermally desorb the sample from the sorbent tube and transfer
                to the gas chromatograph:  (a) tube leak test and (b) leak check flow path.
January 1999
     Compendium of Methods for Toxic Organic Air Pollutants
             Page 17-39

-------
Method TO-17
                                                               VOCs
                             Inlet open
                             (optional)
                 Sorbenttube
                 ambient temp.
        Li
  Coo! sorbent trap
                                          Desorb
                                         flow open \ '
           Carrier
           gas in
          (c)  Purge to remove air.
                                                                            Detector
                                                                    GC analytical
                                                                       column
                               Carrier
                                gas in
      From pressurized
         cylinder of
       standard gas
           Inlet split open
            (optional)
Sorbent tube at
ambient temp.
                             2E
JUVi I


1
                                     Cool sorbent trap
   Internal standard
    addition valve
                                            Desorb
                                           flow open
              Carrier
              gas in
                                     ~?*T
                                                                      GC analytical
                                                                         column
                                Carrier
                                 gas in
          (d) Gas phase internal standard addition to sample tube.
     Figure 3 (cont). Sequence of operations to thermally desorb the sample from the sorbent tube and
      transfer to the gas chromatograph:  (c) purge to remove air and (d) gas phase internal standard
                                  addition to sample tube.
Page 17-40
Compendium of Methods for Toxic Organic Air Pollutants
                                          January 1999

-------
VOCs
                                                              Method TO-17
                        Inlet split open
                          (optional)
           Hot surbent tube
      1
Cool sorbent trap
                                          Desorb
                                         flow open
   Carrier
   gas in

   (e) Primary (tube) desorption.
                               Carrier
                               gas in
                           Outlet split
                           (optional)
      Sorbent tube cooling
     (f) Secondary (trap) desorption.
                                                                                   Detector
                                                                         GC analytical
                                                                            column
                                                                                      Detector
                                                                             GC analytical
                                                                                column
     Figure 3 (cont).  Sequence of operations to thermally desorb the sample from the sorbent tube and
    transfer to the gas chromatograph:  (e) primary (tube) desorption and (f) secondary (trap) desorption.
January 1999
Compendium of Methods for Toxic Organic Air Pollutants
                                                       Page 17-41

-------
Method TO-17
                                                                  VOCs
                                            Adsorbent
                                              Tubes
             Figure 4.  Example of distributive air volume using adsorbent tube technology.
Page 17-42
Compendium of Methods for Toxic Organic Air Pollutants       January 1999

-------
VOCs
                                                           Method TO-17
                                        APPENDIX 1.

The following list includes safe sampling volume data generated by the UK Health and Safety Executive (4) on
single sorbent bed 1/4 inch O.D. stainless steel tubes and compatible with a thermal desorption - capillary GC
analytical procedure. It is provided as a resource to readers only. The recommendation for Tube Style 2 is based
on the specific tube referenced in Section 6.1.2 and Table 3.  Where tubes are not listed with safe sample volumes
they have not been tested and their inclusion represents a suggestion only. Application to air sampling is subject
to criteria listed in Section 14 of Compendium Method TO-17.

[Note: Combination tubes I, 2, and 3 referenced in this Appendix are those adsorbent tubes described in
Section 9.1.3.]
 Compound
      Suitable sorbents and SSV's where available
                                        Hydrocarbons

 This procedure is suitable for all aliphatic, aromatic and cyclic hydrocarbons less volatile than ethane and
 more volatile than n-C20. These include:
 n-Butane
 n-Pentane

 n-Hexane
 Benzene

 n-Heptane

 Toluene

 n-Octane

 Ethylbenzene

 all Xylenes

 n-Nonane

 Styrene
 Isopropylbenzene
 n-Propylbenzene
 l-Methyl-3-ethylbenzene
 1 -Methyl-4-ethylbenzene
      CS III, C 1000, Combination Tubes 2 or 3 or Spherocarb (SSV 820L).
      CS III, C 1000, Spherocarb (SSV 30,OOOL), Combination Tubes 2 or 3 or
      Chromosorb 106 (SSV 5.5L).
      Carbopack™ B, Combination Tubes 1, 2, 3 or Chromosorb 106 (SSV 30L).
      Carbopack™ B, Combination Tubes 1, 2, 3 or Chromosorb 106 (SSV 26L)
      or Tenax (SSV 6L).
      Carbopack™ B, Tenax (SSV 17L), Combination Tubes 1, 2, 3 or
      Chromosorb 106 (SSV 160L).
      Carbopack™ B, Tenax (SSV 38L), Combination Tubes 1, 2, 3 or
      Chromosorb 106 (SSV SOL).
      Carbopack™ B, Tenax (SSV 700L) Combination Tubes 1, 2, 3 or
      Chromosorb 106 (SSV 1000L).
      Carbopack™ B, Tenax (SSV 180L), Combination Tubes 1, 2, 3 or
      Chromosorb 106 (SSV 360L).
      Carbopack™ B, Tenax (SSV 300L), Combination Tubes 1, 2, 3 or
      Chromosorb 106 (SSV 770L).
      Carbopack™ C/B, Tenax (SSV 700L), Combination Tubes 1, 2 or 3 or
      Chromosorb 106 (SSV 7000L).
      Carbopack™ C/B, Tenax  (SSV 300L) or Combination Tubes 1, 2 or 3.
      Carbopack™ C/B, Tenax (SSV 480L) or Combination Tubes 1, 2 or 3.
      Carbopack™ C/B, Tenax  (SSV 850L) or Combination Tubes 1, 2 or 3.
      Carbopack™ C/B, Tenax (SSV 1000L) or Combination Tubes 1, 2 or 3.
      Carbopack™ C/B, Tenax (SSV 1000L) or Combination Tubes 1, 2 or 3.
January 1999
Compendium of Methods for Toxic Organic Air Pollutants
Page 17-43

-------
Method TO-17
                                                                  VOCs
 Compound
      Suitable sorbents and SSV's where available
 1,3,5 -Trimethylbenzene

 Methylstyrene
 Methyl-2-ethylbenzene
 1,2,4-Trimethylbenzene
 n-Decane

 1,2,3 -Trimethylbenzene
 n-Undecane
 n-Dodecane
      Carbopack™ C/B, Tenax (SSV 1800L), Combination Tubes 1, 2 or 3 or
      Chromosorb 106 (SSV 2800).
      Carbopack™ C/B, Tenax (SSV 1200L) or Combination Tubes 1, 2 or 3.
      Carbopack™ C/B, Tenax (SSV 1000L) or Combination Tubes 1, 2 or 3.
      Carbopack™ C/B, Tenax (SSV 1800L) or Combination Tubes 1, 2 or 3.
      Carbopack™ C/B, Tenax (SSV 2100L), Combination Tubes 1, 2 or 3 or
      Chromosorb 106 (SSV 37,OOOL).
      Carbopack™ C/B, Tenax (SSV 1800L) or Combination Tubes 1, 2 or 3.
      Carbopack™ C/B, Tenax (SSV 12,OOOL) or Combination Tubes 1, 2 or 3.
      Carbopack™ C, Tenax (SSV 63,OOOL) or Combination Tubes 1 or 3.
                          Halogenated Hydrocarbons including PCBs

 This procedure is suitable for all aliphatic, aromatic and cyclic halogenated hydrocarbons more volatile than
 n-C20. Examples include:
 Dichloromethane
 1,2-Dichloroethane

 1,1,1 -Trichloroethane

 Carbontetrachloride

 Trichloroethylene

 1,1,2-Trichloroethane

 Tetrachloroethylene

 Chlorobenzene

 1,1,1,2-Tetrachloroethane

 1,1,2,2-Tetrachloroethane
      CS III, C 1000, Spherocarb (SSV 200L) or Combination Tubes 2 or 3.
      CS III, C 1000, Spherocarb, Chrom. 106 (SSV 17L), Carbopack™ B, Tenax
      (SSV 5.4L) or Combination Tubes 1, 2 or 3.
      Spherocarb (SSV 8,OOOL), Chrom. 106 (SSV 8L), Carbopack™ B, or
      Combination Tubes 1, 2 or 3.
      Chrom. 106 (SSV 22L), Carbopack™ B, Tenax (SSV 6.2L) or Combination
      Tubes 1, 2 or 3.
      Chrom. 106, Carbopack™ B, Tenax (SSV 5.6L) or Combination Tubes 1, 2
      or 3.
      Chrom. 106, Carbopack™ B, Tenax (SSV 34L) or Combination Tubes 1, 2
      or 3.
      Chrom. 106, Carbopack™ B, Tenax (SSV 48L) or Combination Tubes 1, 2
      or 3.
      Chrom. 106, Carbopack™ B, Tenax (SSV 26L) or Combination Tubes 1, 2
      or 3.
      Chrom. 106, Carbopack™ B, Tenax (SSV 78L) or Combination Tubes 1, 2
      or 3.
      Chrom. 106, Carbopack™ B, Tenax (SSV 170L) or Combination Tubes 1, 2
      or 3.
Page 17-44
Compendium of Methods for Toxic Organic Air Pollutants
January 1999

-------
VOCs	Method TO-17

 Compound	Suitable sorbents and SSV's where available	
                                          Alcohols

 This procedure is suitable for alcohols more volatile than n-C20 and sufficiently stable to be analyzed by
 conventional GC techniques. Examples include:

 Methanol                 CSIII, C1000, Spherocarb (SSV 130L) or Combination Tubes 2 or 3.
 Ethanol                   CSIII, C1000, Spherocarb (SSV 3500L) or Combination Tubes 2 or 3.
 n-Propanol                Porapak N (SSV 20L), Chrom 106 (SSV 8L), Carbopack™ B or
                          Combination Tubes 1, 2 or 3.
 Isopropanol               Chrom 106 (SSV 44L), Carbopack™ B or Combination Tubes  1, 2 or 3.
 n-Butanol                 Chrom 106 (SSV SOL), Carbopack™ B, Porapak N (SSV 5L), Tenax (SSV
                          5L) or Combination Tubes 1, 2 or 3.
 iso-Butanol               Chrom 106 (SSV 30L), Carbopack™ B, Tenax (SSV 2.8L) or Combination
                          Tubes 1, 2 or 3.
 Octanol                   Tenax (SSV 1400L), Carbopack™ C or Combination Tubes 1 or 3.

                                   Esters and Gycol Ethers

 This procedure is suitable for all esters and glycol ethers more volatile than n-C20 and sufficiently stable to
 be analyzed by conventional GC techniques. Examples include:

 Methylacetate              Chromosorb 106 (SSV 2.6L), Carbopack™ B or Combination Tubes 1, 2 or
                          3.
 Ethylacetate               Chromosorb 106 (SSV 20L), Carbopack™ B, Tenax (SSV 3.6L) or
                          Combination Tubes 1, 2 or 3.
 Propylacetate              Chromosorb 106 (SSV 150L), Carbopack™ B, Tenax (SSV 18L) or
                          Combination Tubes 1, 2 or 3.
 Isopropylacetate            Chromosorb 106 (SSV 75L), Carbopack™ B, Tenax (SSV 6L) or
                          Combination Tubes 1, 2 or 3.
 Butylacetate               Chromosorb 106 (SSV 730L), Carbopack™ B, Tenax (SSV 85L) or
                          Combination Tubes 1, 2 or 3.
 Isobutylacetate             Chromosorb 106 (SSV 440L), Carbopack™ B, Tenax (SSV 130L) or
                          Combination Tubes 1, 2 or 3.
 Methyl-t-butyl ether        Chromosorb 106 (SSV >6L), Carbopack™ B or Combination Tubes 1, 2 or
                          3.
 t-Butylacetate              Chromosorb 106 (SSV 160L), Carbopack™ B or Combination  Tubes 1, 2 or
                          3.
 Methylacrylate             Chromosorb 106, Carbopack™ B, Tenax (SSV 6.5L) or Combination Tubes
                          1,2 or 3.
January 1999        Compendium of Methods for Toxic Organic Air Pollutants          Page 17-45

-------
Method TO-17
                                                                  VOCs
 Compound
      Suitable sorbents and SSV's where available
 Ethylacrylate

 Methylmethacrylate

 Methoxyethanol

 Ethoxyethanol

 Butoxyethanol

 Methoxypropanol

 Methoxyethylacetate

 Ethoxyethylacetate

 Butoxyethylacetate
      Chromosorb 106, Carbopack™ B, Tenax (SSV 60L) or Combination Tubes
      1,2 or 3.
      Chromosorb 106, Carbopack™ B, Tenax (SSV 27L) or Combination Tubes
      1,2 or 3.
      Chromosorb 106 (SSV 5L), Carbopack™ B, Tenax (SSV 3L) or
      Combination Tubes 1, 2 or 3.
      Chromosorb 106 (SSV 75L), Carbopack™ B, Tenax (SSV 5L) or
      Combination Tubes 1, 2 or 3.
      Chromosorb 106, Carbopack™ B, Tenax (SSV 35L) or Combination Tubes
      1,2 or 3.
      Chromosorb 106, Carbopack™ B, Tenax (SSV 13L) or Combination Tubes
      1,2 or 3.
      Chromosorb 106 (SSV 860L), Carbopack™ B, Tenax (SSV 8L) or
      Combination Tubes 1, 2 or 3.
      Chromosorb 106 (SSV 4000L), Carbopack™ B, Tenax (SSV 15L) or
      Combination Tubes 1, 2 or 3.
      Chromosorb 106, Carbopack™ B, Tenax (SSV 150L) or Combination Tubes
      1,2 or 3.
                                   Aldehydes and Ketones

 This procedure is suitable for all aldehydes and ketones more volatile than n-C20 and sufficiently stable to
 be analyzed using conventional GC techniques. Examples include:
 Acetone

 Methylethylketone
 (2-butanone)
 n-Butanal

 Methylisobutylketone

 Cyclohexanone

 3,5,5-Trimethylcyclohex-2-
 enone
 Furfural
      CSIII, C1000, Spherocarb, Chrom 106 (SSV 1.5L) or Combination Tubes 2
      or 3.
      Chromosorb 106 (SSV 10L), Tenax (SSV 3.2L), PorapakN (SSV SOL)
      Carbopack™ B or Combination Tubes 1, 2 or 3.
      Chromosorb 106, Carbopack™ B, PorapakN (SSV SOL) or Combination
      Tubes 1, 2 or 3.
      Chromosorb 106 (SSV 250L), Tenax (SSV 26L), Carbopack™ B or
      Combination Tubes 1, 2 or 3.
      Chromosorb 106, Tenax (SSV 170L), Carbopack™ B or Combination Tubes
      1,2 or 3.
      Tenax (SSV 5600L), Carbopack™ B or Combination Tubes 1 or 3.

      Tenax (SSV 300L), Carbopack™ B or Combination Tubes 1, 2 or 3.
Page 17-46
Compendium of Methods for Toxic Organic Air Pollutants
January 1999

-------
VOCs
                                                           Method TO-17
 Compound
      Suitable sorbents and SSV's where available
                                     Miscellaneous VOCs

 This procedure is suitable for the analysis of most VOCs in air. It is generally compatible with all organics
 less volatile than ethane, more volatile than n-C20 and sufficiently stable to be analyzed using conventional
 GC techniques. Examples include:
 Acetonitrile
 Acrylonitrile
 Propionitrile
 Maleic anhydride3

 Pyridine

 Aniline

 Nitrobenzene
 Acetic acid
 Phenol
      Porapak N (SSV 3.5L), CSIII, C1000 or Combination Tubes 2 or 3.
      Porapak N (SSV 8L), Carbopack™ B or Combination Tubes 1, 2 or 3.
      Porapak N (SSV 11L), Carbopack™ B or Combination Tubes 1, 2 or 3.
      Tenax (SSV 88L), Chrom. 106, Carbopack™ B or Combination Tubes 1, 2
      or 3.
      Tenax (SSV 8L), Porapak N (SSV 200L) Chrom. 106, Carbopack™ B or
      Combination Tubes 1, 2 or 3.
      Tenax (SSV 220L), Chrom. 106, Carbopack™ B or Combination Tubes 1, 2
      or 3.
      Tenax (SSV 14,OOOL) Carbopack™ C or Combination Tubes 1 or 3.
      Porapak N (SSV SOL), Carbotrap™ B or Combination Tubes 1, 2 or 3.
      Tenax (SSV 240L) or combination tube 1.
January 1999
Compendium of Methods for Toxic Organic Air Pollutants
Page 17-47

-------
Method TO-17
                                                                    VOCs
                                         APPENDIX 2.

       LINEARITY TESTING OF ONE SORBENT TUBE/FOCUSING TUBE COMBINATION

                                         Introduction

       Automated gas chromatographs such as those used at network monitoring stations for hourly updates
of volatile organic compounds (VOCs) have a solid adsorbent concentrator for the VOCs.  This unit is
comparable to the sorbent tubes being discussed in this document.  The table below shows the results of sampling
a synthetic mixture of the Compendium Method TO-14 target list in humidified zero air (approximately 70% RH
at 25 °C).  Sampling occurred for 6, 12, and 24 min at a rate of 80 mL/min giving a total sampling volume of 480,
960, and  1920 mL. These results are similar to the determination of safe sampling volume and the amount of
material collected should be related linearly to the sample period. The results indicate that breakthrough has not
occurred  to any appreciable extent at a sampling volume of approximately 2 L for the stated experimental
conditions.   The  response measured is the response of chlorine from  an atomic emission detector  after
chromatographic separation.  The sorbent tube mix was Carbotrap™ C/Carbotrap™ B/Carboxen™ 1000 and
the focusing tube mix was Tenax-TA/Silica Gel/Ambersorb XE-340/Charcoal. The primary tube was 6 mm O.D.
with 4 mm ID., 110 mm in length.  The focusing tube was 6 mm O.D., 0.9 mm I.D., 185 mm in length.  The
packing lengths for the sorbent tube per sorbent type were: 1.27 cm, 2.86 cm, and 3.18 cm, respectively.  The
packing lengths for the focusing tube per sorbent type were: 5.08 cm, 2.54 cm, and 1.27 cm.

                                         Linearity test

[Note: Actual sampling volumes were 490, 980, and I960 instead of 1/2,1, and 2L as listed for convenience
in  the  table below.  The response is obtained  as chlorine response on an atomic  emission detector.
Compounds corresponding to the numbered compounds in  the table are identified on the following page.]
Cpd.
1
2
o
5
4
6
7
8
9
10
11
12
13
14
15
16
1/2 L
1255.4
711.82
2079.4
978.14
1155.7
3072.8
2337.3
3041.7
1061.7
3800.5
2386.9
2455.4
3972.6
2430.9
6155.4
1L
2402.9
1802.2
4853
2381.3
2357.1
6764.4
4356.1
5986.6
2183.6
7726.7
4877.5
5063.5
8118.4
4947.9
9247.4
2L
5337.2
3087
9386
4680.1
4725.2
13662
8697.2
11525
4296.5
15182
9669
9986.6
15985
9756.1
16942
2L/1L
2.22
1.71
1.93
1.97
2.00
2.02
2.00
1.93
1.97
1.96
1.98
1.97
1.97
1.97
1.83
2L/(1/2L)
4.25
4.34
4.51
4.78
4.09
4.45
3.72
3.79
4.05
3.99
4.05
4.07
4.02
4.01
2.75
1L/(1/2L)
1.91
2.53
2.33
2.43
2.04
2.20
1.86
1.97
2.06
2.03
2.04
2.06
2.04
2.04
1.50
% Diff
(2L/0.5L) vs.
4
-6.28
-8.42
-12.85
-19.62
-2 22
-11.15
6.97
5.28
-1.17
0.13
-1.27
-1.68
-0.60
-0.33
31.19
Page 17-48
Compendium of Methods for Toxic Organic Air Pollutants
January 1999

-------
VOCs
                                                                        Method TO-17
Cpd.
18
19
20
21
22
23
26
27
31
36
37
38
39
40
41
1/2 L
4270.4
2494.8
4023.9
1086.8
793.33
3708.2
5094
1265.1
4434.9
2320.7
441.17
1410.7
2338.7
2640.9
6796.5
1L
9233.8
5115.2
8379.4
2295.4
1670.1
7679
10582
2615.1
9176.4
5015.7
953.09
3015
4974.8
6269.4
14938
2L
18721
10087
16672
4611.7
3375.2
15165
21139
5136.9
17975
9827.3
1894
5895.2
9858.8
12495
29274
2L/1L
2.03
1.97
1.99
2.01
2.02
1.97
2.00
1.96
1.96
1.96
1.99
1.96
1.98
1.99
1.96
2L/(1/2L)
4.38
4.04
4.14
4.24
4.25
4.09
4.15
4.06
4.05
4.23
4.29
4.18
4.22
4.73
4.31
1L/(1/2L)
2.16
2.05
2.08
2.11
2.11
2.07
2.08
2.07
2.07
2.16
2.16
2.14
2.13
2.37
2.20
% Diff
(2L/0.5L) vs.
4
-9.60
-1.08
-3.58
-6.08
-6.36
-2.24
-3.74
-1.51
-1.33
-5.87
-7.33
-4.47
-5.39
-18.28
-7.68
There are no values presented in the above table for hydrocarbons and brominated hydrocarbons (compounds numbered 5, 17,24,25,
28,29, 30, 32, 33, 34, and 35) which do not respond to the chlorine detector used to collect this data.

                                            Compendium Method TO-14
 1.   Dichlorodifluoromethane
 2.   Methyl Chloride
 3.   1,2-dichloro-1,1,2,2-tetrafluoroethane
 4.   Vinyl Chloride
 5.   Methyl Bromide
 6.   Ethyl Chloride
 7.   Trichlorofluoromethane
 8.   1,1-dichloroethene
 9.   Dichloromethane
10.  3-chloropropene
11.  l,l,2-trichloro-l,2,2-trifluoroethane
12.  1,1-dichloroethane
13.  Cis-l,2-dichloroethene
14.  Trichloromethane
15.  1,2-dichloroethane
16.  1,1,1-trichloroethane
17.  Benzene
18.  Carbon Tetrachloride
19.  1,2-dichloropropane
20.  Trichloroethene
21.  Cis-1,3-dichloropropene
Target Compound List (TCL)
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
38.
39.
40.
41.
Trans- 1 ,3-dichloropropene
1 , 1 ,2-trichloroethane
Toluene
1 ,2-dibromoethane
Tetrachloroethene
Chlorobenzene
Ethylbenzene
m,p-xylene
Styrene
1 , 1 ,2,2-tetrachloroethane
o-xylene
4-ethyltoluene
1 ,3,5-trimethylbenzene
1 ,2,4-trimethylbenzene
m-dichlorobenzene
Benzyl Chloride
p-dichlorobenzene
o-dichlorobenzene
1 ,2,4-trichlorobenzene
Hexachlorobutadiene
January 1999
Compendium of Methods for Toxic Organic Air Pollutants
Page 17-49

-------