Home Performance with ENERGY STARฎ
Sponsor Guide
HOME PERFORMANCE WITH
Wr ENERGY STAR
Version 1.1
August 2011
H ome Performance with ENERGY STAR
August 2011

-------
Table of Contents
Table of Contents	ii
Acknowledgements	iv
Introduction 	v
EPA and DOE Support	viii
Acronyms and Abbreviations	x
Chapter 1 ENERGY STAR Brand and Requirements	1-1
Chapter 2 Program Planning (Section B)	2-1
2.1	Introduction	2-1
2.2	Metrics by Which to Gauge the Success of the Program: Goals and
Objectives 	2-2
2.2.1 Implementation Schedule	2-2
2.3	A Budget Addressing Key Elements of Program Design	2-4
2.4	Contractor Participation Agreement: Recommended and Required Elements	2-5
2.5	Marketing/Media Plan	2-5
2.5.1 Target Market	2-6
2.6	Incentives Structure/Financing Plan	2-6
2.6.1	Program Design	2-7
2.6.2	Home Performance Protocols	2-7
2.6.3	Contractor Recruitment Plan	2-7
2.7	Program Evaluation	2-8
2.7.1	Contractor Training	2-9
2.7.2	Contractor Participation Agreement	2-9
Chapter 3 HPA Summary Report (Findings and Recommendations)	3-1
3.1	Scope of Work Review	3-2
3.2	Estimating Energy Savings	3-2
3.3	Estimating Energy Use for Different Purposes	3-3
3.3.1	Aggregate Energy Savings	3-3
3.3.2	Home Specific Energy Savings	3-3
3.3.3	Methods to Calculate Energy Savings	3-3
3.3.4	Energy Modeling to Create Deemed Savings	3-4
3.4	Energy Modeling Software for Use by Contractors	3-5
3.5	Actual Energy Usage	3-6
3.6	Limitations of All Methods of Energy Savings Estimations	3-7
3.7	Other Energy Performance Estimations	3-7
Home Performance with ENERGY STAR	jj	August 2011

-------
3.8	Estimating Programmatic Energy Savings	3-8
3.9	Installation of Measures	3-9
3.10	Inspection Results and Recommended Improvements	3-9
3.10.1	Introduction	3-9
3.10.2	Elements of the Summary Certificate	3-9
3.11	Post-installation Test or "Test-out" Protocols	3-11
3.11.1	Introduction	3-11
3.11.2	Program Oversight of Post Installation or "Test-out" Requirements	3-11
Chapter 4 Quality Assurance Plan	4-1
4.1	Introduction	4-1
4.2	Required Elements	4-2
4.3	Job Reporting Review	4-2
4.3.1 Optional Report Review Process	4-2
4.4	Example Job Report Review Evaluation	4-3
4.4.1	HPA Summary Report Review	4-3
4.4.2	Test-out Report Review	4-4
4.4.3	Example On-site Inspection Scoring Methodology	4-4
4.5	Test-out Report Review	4-7
4.5.1 Optional Report Review Process	4-7
4.6	On-site Inspection Protocols	4-8
4.7	Job Selection Protocol	4-8
4.8	Visual Inspections and Diagnostic Tests	4-9
4.9	Customer Discussion	4-10
4.10	Contractor Performance Record	4-10
4.11	Customer Feedback	4-11
4.12	Contractor Follow-up	4-12
4.13	Contractor Feedback and Corrective Actions	4-12
4.14	Example Contractor Feedback and Corrective Action Levels	4-13
4.15	Inspection Documentation	4-15
4.16	Program Data Reporting Requirements	4-15
4.17	Your Contractors	4-15
4.18	Quarterly Reporting	4-16
4.19	Annual Summary	4-17
4.20	Active Status Requirements	4-17
Appendix A	HPwES Partnership Agreement
Appendix B	Program Implementation Plan Template
Home Performance with ENERGY STAR	jjj	August 2011

-------
Acknowledgements
The Home Performance with ENERGY STAR Sponsor Guide would not be possible without the input
of EPA and DOE's partners in the industry. This group includes the Home Performance with
ENERGY STAR sponsor partners and stakeholders listed below. These individuals contributed their
time and expertise to review and provide comments, which was invaluable to the creation of this
Guide.
Technical Reviewers
Steve Baden, Residential Energy Services Network
Amy Beley, ICF International
Andrew Fisk, New York State Energy Research and Development Authority
Jim Fitzgerald, Conservation Services Group
AsaFoss, SENTECH
Jerry Hannah, National Grid
Sue Hanson, Wisconsin Energy Conservation Corporation
Bruce Harley, Conservation Services Group
John Jones, New York State Energy Research and Development Authority
Pat Justis, Missouri Department of Natural Resources
Joe Kuonen, Building Performance Institute
Emily Levin, Efficiency Vermont
Michael L'Ecuyer, ICF International
Jim Maletta, North Star Energy Consulting
Marc Milin, ICF International
Casey Murphy, ICF International
Paul Norton, National Renewable Energy Laboratory
Bob O'Brien, National Grid
William J. Parlapiano III, BP Consulting
Bob Pfeiffer, Wisconsin Energy Conservation Corporation
Patricia Plympton, Navigant Consulting
Ed Schmidt, Northeast Energy Efficiency Partnerships, Inc.
Greg Thomas, Performance Systems Development
David Weitz, Conservation Services Group
Larry Zarker, Building Performance Institute
Bill Zwack, SENTECH
Home Performance with ENERGY STAR
iv
August 2011

-------
Introduction
Home Performance with ENERGY STAR (HPwES) offers whole-house solutions to increasing the
energy performance and comfort of existing homes while improving the environment. The program
is delivered by local Program Sponsors that recruit and train home improvement contractors and
consultants (here after referred to as "contractor") who are qualified to perform home performance
assessments (also called comprehensive home energy audit). The assessment includes the heating
and cooling systems, windows, insulation, flow of air into and out of the house, as well as a safety
check of combustion appliances. Based on this assessment, participating contractors offer solutions
to solve home comfort problems and reduce energy usage while decreasing the carbon footprint of
the home. Another important element of HPwES is that, upon project completion, the contractor
assesses the home's performance again (a "test out") to document that specified improvements
were properly installed to maximize the promised energy savings. Finally, all participating
contractors are subject to quality assurance (QA) reviews by the third-party sponsor to ensure that
projects meet program standards and homeowners receive high-quality work. The goal of HPwES is
to turn building science based recommendations into improved homes.
The first step of starting a HPwES program is to develop an implementation plan that explains the
scope and objectives of the program. The implementation plan includes the policies and procedures
that will ensure the success of the local program and compliance with National ENERGY STAR
requirements and aligns with the Partnership Agreement signed by the Sponsor. This Guide was
developed to provide guidance on the development of a Home Performance with ENERGY STAR
program. It is organized to align closely with the Partnership Agreement.
Each Section of this Guide covers the following topics:
•	Introduction with a general overview of the topic.
•	Description of Required elements that highlight key elements that a sponsor will address and
those that are optional.
•	Recommended Elements to enhance program design and deployment
•	Examples or templates, where applicable, that provide a visual illustration of required or
recommended elements. These examples and templates are available only for Program Sponsor use
and can be customized by request.
The recommendations in this guide are not meant to be a 'one-size-fits-all' manual for
developing a successful HPwES Program, as regional factors and organizational preferences
are important and will vary. This guide does provide perspective on the major components
of program design and delivery that are required and those that are recommended for local
sponsors to implement.
This Guide covers the following topics:
1.	ENERGY STAR: Brand Requirements
2.	Program Planning - Provides general guidance to develop a HPwES Program Plan. Each plan
will be different, but the planning process includes common elements every program must
consider.
Home Performance with ENERGY STAR
V
August 2011

-------
3.	Program Requirements
a.	Contractor Participation Agreement Requirements and Recommended Elements
b.	Home Performance Assessment (HPA) or "Test-in" - Defines the minimum requirements and
recommendations for assessing a home's energy performance under the HPwES program.
The local HPwES program can either meet or exceed National HPwES requirements.
1) HPA Intake Form - a template to facilitate the delivery of an HPA that can be used by
Program Sponsors as a template to provide to their participating contractors
c.	Homeowner HPA Summary Report Form -an example of how to summarize HPA
information and recommendations for the customer in an easily understandable and
compelling manner that could assist the participating contractor sell energy improvements.
The Homeowner Summary Report can also be used to report information to the Program
Sponsor for QA tracking.
d.	Estimating Energy Savings MORE
e.	Post-Installation Tests or "Test-out" - Defines the minimum level of diagnostic and visual
inspections to be completed by participating contractors at the conclusion of a job.
1)	Test-out Report Form - a sample form for the test-out data and installed measures
which can be provided to the local Program Sponsor for QA tracking
2)	HPwES Summary Certificate - recommendations on issuing a summary certificate that
lists the work completed and organizations involved. This certificate can be presented
to the homeowner by the local program sponsor after receipt of the Test-out Report
Form and completion of the QA review process.
3)	HPwES Certificate Template - an example template that Program Sponsors can
customize for their use.
4.	Quality Assurance Requirements and Protocols - defines the minimum requirements for
program QA that applies to participating contractors. To use the HPwES logo, sponsors and EPA
need assurance that contractors participating in the program are a legitimate business (licensed
& insured) and have properly trained personnel to deliver efficiency improvements.
Programmatic QA starts with recruitment of professional businesses that sign a Participation
Agreement with the sponsor that spells out the program's "rules of engagement". This
Participation Agreement defines, among other programmatic details (incentives, reporting,
certification requirements, marketing, data management, etc) how the sponsor will ensure
quality delivery from it's participating contractors. Starting with:
a.	Job Reporting File Review - defines requirements and provides recommendations for
developing program policies and procedures to perform QA reviews. The job reporting
review focuses on the Homeowner HPA Summary and Test-out Reports, and the contracted
scope of work. It provides guidance on what to look for in the paperwork review process
and next steps to follow if issues with paperwork indicate further investigation is
warranted.
b.	On-site Inspection Protocols - defines requirements and provides recommendations for
developing program policies and procedures for performing on-site inspections on
participating contractors' completed jobs. Provides guidance on the on-site inspection
process, sampling rates, and a contractor performance scoring methodology.
Home Performance with ENERGY STAR
vi
August 2011

-------
c.	Customer Feedback - defines and provides guidance on meeting the requirement of
obtaining customer feedback on participating contractor's work completed through the
development and use of customer surveys.
d.	Contractor Feedback and Corrective Action - provides recommendations for how to provide
feedback to participating contractors on the results of a QA review (including paperwork,
on-site, and customer survey). This guidance provides recommended corrective action
levels and contractor de-listing procedures
This guide denotes which aspects are required program elements per the Partnership Agreement,
found in Appendix A. Some Headings indicate the corresponding section in the Partnership
Agreement (e.g., for Quality Assurance Requirements relevant to file review, the section will denote
"Section D, part 2"). This document provides guidance on required elements for a Home
Performance with ENERGY STAR program and recommended measures to enhance your program.
Home Performance with ENERGY STAR
vii
August 2011

-------
EPA and DOE Support
At th e Nati o nal level EPA an d D 0 E offer a vari ety o f to o 1 s f or pro gram develo pm ent an d
design recruiting contractors, marketing to homeowners, and sales training for
contractor participants. These tools are offered free-of-charge to Program Sponsors and
di s cu s se d further bel o vv:
HOME
PERFORMANCE
ENERGYSTAR
Program Design:
o Consumer-recognized brand: Program Sponsors can download anduse this logo in
promotional materials, including Web sites and advertisements.
o Program start-up assistance: EPA and DOE can provide assistance to sponsors and
utilities interested in exploring and planning a HPwES Program. We strongly recommend
contacting EPA/DOE early in the process of building your HP wES plan.
o Program Development Fact Sheets: Program Sponsors can download program
development fact sheets covering key program elements including contractor recruiting
contractor and consultant business models and quality assurance.
o Case-by-case program development support: Program Sponsors may request additional
support from EPA and DOE beyond what is listed above
o Logo Use Guidelines: EPA can provide you with training resources to ward training your
staff and contractors how to use the logo correctly
o HPwES Symp osium: Once a year at the .Affordable Comfort Incorporated National
Conference we provide sessions to strengthen our sponsor's program with a HPwES specific
track and a distinct session justfor our sponsors.
o Insurance Q&A: This document provides guidance on requiring insurance and good
business practices from your contractors
o Marketing tools: Google Adwords, Pitch Book, HPwES banner for promotional events
(recruiting contractors or homeowners), ability to reserve HPwES booth for conferences
and outreach events, introductory HPwES video, high resolution graphics
Marketing t o H ome own ers:
o Home Energy Yardstick: Program Sponsors can host ENERGY STAR'S Home Energy
Yardstick on their web site to help homeowners take the first step to ward HPwES. The
Yardstick can be a great screening tool to determine how serious ahomeownermay be
regarding improving the performance of their home.
o Utility Bill Disaggregating Tool: Sponsors can provide this tool to contractors to
disaggregate utility bills of prospective customers to determine how energy is used in
homes.
o Consumer Brochure: Program Sponsors and participating contractors can use this
brochure to educate homeowners about the benefits of HPwES.
Recruiting Contractors:
Home Perfomiarce with E tje RGYSTAR
viii
fiigust 2011

-------
o Contractor Business Development Guide: This special edition of Home Energy Magazine
includes several contractor business success stories that can help Program Sponsors
educate contractors about the whole-house contracting business model.
o Sales training for contractors: Since home performance contracting is significantly
different than other home improvement services due to its comprehensive nature, program
sponsors recognize that participating contractors are more successful if they educate their
homeowners and change their sales tactics accordingly. This training focuses on teaching
in-office and in-home strategies to help participating contractors educate homeowners on
the benefits and therefore sell comprehensive home performance improvements. EPA and
DOE's resources are limited, therefore please contact us to see if this training is available.
o Marketing Toolkit / Consumer Video: This online tool allows sponsors and participating
contractors to create customized marketing materials, such as ads, fact sheets, and direct
mail pieces, to promote HPwES.
o Support your Program's Kick Off with a Recruitment Event: Working with Affordable
Comfort, Inc.(ACI), augment your program kickoff event with a "Profit from HP" V2 day
session designed to motivate / educate contractors on the business value of delivering HP
services. EPA and DOE have limited resources for these activities so make your request as
early as possible.
Home Performance with ENERGY STAR
ix
August 2011

-------
Acronyms and Abbreviations
ACCA
Air Conditioning Contractors of America
ACI
Affordable Comfort, Inc.
AFUE
Annual Fuel Utilization Efficiency
AHRI
Air Conditioning, Heating, and Refrigeration Institute
ANSI
American National Standards Institute
ASHRAE
American Society of Heating, Refrigerating, and Air Conditioning Engineers, Inc.
ASTM
American Society for Testing and Materials
BPI
Building Performance Institute
CAZ
combustion appliance zone
CFL
Compact Fluorescent Lamp
CO
Carbon Monoxide
DEER
California Database for Energy Efficiency Resources
DHW
Domestic Hot Water
DOE
U.S. Department of Energy
DSM
demand-side management
EER
Energy Efficiency Ratio
EF
Energy Factor
EPA
U.S. Environmental Protection Agency
HPA
Home Performance Assessment
HPwES
Home Performance with ENERGY STAR
HVAC
Heating, Ventilation, and Air Conditioning
IPMVP
International Performance Measurement and Verification Protocol
LiUNA
Laborers' International Union of North America
MESA
My ENERGY STAR Account
NAHB
National Association of Homebuilders
NAPEE
National Action Plan for Energy Efficiency's
NARI
National Association of the Remodeling Industry
NEAT
National Energy Audit Tool
NFPA
National Fire Protection Association
NHPC
National Home Performance Council
QC
Quality Control
RESNET
Residential Energy Services Network
SEER
Seasonal Energy Efficiency Ratio
SSE
Steady State Efficiency
WAP
Weatherization Assistance Program
Home Performance with ENERGY STAR
X
August 2011

-------
Chapter 1
ENERGY STAR Brand and Requirements
ENERGY STAR is a nationally recognized label across products, appliances, new and existing homes.
More than 17,000 businesses and organizations have become ENERGY STAR partners. The brand
identity is a valuable asset, which must be properly used and protected. Proper and consistent use
of the logo builds value and reinforces sponsor and contractor connections to the larger national
program. EPA tracks all logo use and actively works to protect the trademark and the words
"ENERGY STAR."
Web Linking
Sponsors have the opportunity for their online listing on the ENERGY STAR website (displayed at
www.eoergvstar.gov/iodex.cfai?e^hoete improveoieot.hoi Unprovetneot hpwes partners) to be
web linked to their own web site.
•	Ensure your site meets the ENERGY STAR Web Linking Policy, detailed at
www.energystar.gov/weblinking. All of the required information must appear on the same
page.
1)	Display the ENERGY STAR Partner logo in compliance with the Identity Guidelines at
www ,e oe rgv sta r.gov/ lo go s.
2)	Reference or provide a reciprocal link to the ENERGY STAR Web site,
www .eoe rgv sta r.gov.
3)	Include a brief description of your organization's participation in ENERGY STAR.
•	Once these requirements are met, email homeperformance@energystar.gov to request that your
web site be reviewed for web linking. Be sure to provide the specific address for the web page
that you wish to link to.
The hyper link from the ENERGY STAR Web site will be directed to the webpage on the partner's site
that contains these required elements.
Note that meeting the Web Linking Policy is optional. Active Partners who do not wish to have a
hyperlink to their website will continue to be listed on the ENERGY STAR website. However, we
strongly encourage all sponsors to establish this hyperlink for ease of overall program consistency
and review.
ENERGY STAR logos
As a Partner of Home Performance with ENERGY STAR who has signed a Partnership Agreement,
you have the privilege to use both the ENERGY STAR Partner logo and the Home Performance with
ENERGY STAR logo. You can download both logos atwww.eoergystar.gov/logos or through
accessing MESA at www ,e oe rgv s ta r.gov/me sa. Only participating contractors in our HPwES
programs have the privilege to utilize the Home Performance with ENERGY STAR logo and can
download this logo through accessing MESA.
Home Performance with ENERGY STAR
1-1
August 2011

-------
Use the Home Performance with ENERGY STAR logo to promote a comprehensive, whole-house
energy-efficiency improvement service in accordance with Home Performance with ENERGY STAR
criteria outlined in the Home Performance with ENERGY STAR Partnership Agreement. The logo
may be used in marketing and advertising materials to educate consumers or to show that a
company provides services that clearly contribute to the integrated improvement of homes' systems
as recommended by EPA's ENERGY STAR Program.
Correct Use of Graphic
Use of the logo includes Promotional and Educational material, and Web Sites. Use of the logo may
also include T-shirts, hats, letterhead, business cards, and other stationery; and company-owned
cars and vans, etc.
Because Home Performance with ENERGY STAR is a relatively new service in several markets, it is
recommended that the following language appear next to the Home Performance with ENERGY
STAR logo where applicable for educational purposes: '"Working to deliver whole-house energy
savings to improve comfort and help protect the environment."
Any display of the ENERGY STAR logos must adhere to the Identity Guidelines. Please review the
full Guidelines at www.eoergvstar.gw/logos.
The Program Sponsor, as agreed to in the Home Performance with ENERGY STAR Partnership
Agreement, is responsible for ensuring that Program participants use the graphic consistent with
the terms of these guidelines. Additionally, Program Sponsors should approve Program
participants' use of the Home Performance with ENERGY STAR Marketing Graphic in marketing and
advertising campaigns as well as Program facts that feature the ENERGY STAR name prior to final
production or printing.
Home Performance with ENERGY STAR
1-2
August 2011

-------
Chapter 2
Program Planning (Section B)
2.1 Introduction
One of the best ways to start a Home Performance with ENERGY STAR (HPwES) program is to begin
by reviewing the www.eoergvstar.gov/homeperfortnance web site. After reviewing our site, feel
free to contact us for more preliminary information. Your next step should be to set goals for your
program to achieve, assessing the barriers that inhibit energy efficiency retrofits in your chosen
target market and preparing a plan to overcome those barriers. A HPwES template for a HPwES
program plan is available that allows potential sponsors to focus on key delivery elements.
However, every market is different and each plan is tailored to the specific market conditions of the
sponsor. This section highlights the key ingredients needed to develop a HPwES Program Plan. For
a simplified outline of suggested sections to include in your plan, please refer to HPwES Program
Plan Template in Appendix A
A HPwES Sponsor is responsible for overseeing the program's implementation and work completed
by participating home performance contractors. Sponsors have traditionally been State, county or
municipal governments, public utilities, or nonprofit organizations chartered by a state or public
utility to implement energy efficiency programs. Yet any organization that can meet the criteria (as
detailed in this guide) of HPwES will be considered. In general, sponsors commit to providing third-
party oversight of improvements completed by participating home performance contractors,
protecting the ENERGY STAR brand, and serving the public's interest. The Sponsor organization
funds the program, but may decide to contract with other organizations (i.e. program
implementation contractor) to assist with planning and day-to-day implementation or the program.
The Sponsor is required to submit a program plan detailing the program requirements for which the
Sponsor is responsible, which are outlined in Section B of the Partnership Agreement, and described
in more detail below. The Implementation Plan Template (Appendix C) provides sponsors with a
guideline for developing a program plan that meets the required elements of a HPwES program
which include:
•	Metrics by which to gauge the success of the program
•	A budget that addresses key elements of program design
•	Contractor participation agreement which details program requirements
•	Marketing Plan
•	Incentives Structures and financing options, if applicable
•	Description of energy savings estimation tools or estimation protocols
•	Program evaluation plan
The Program Plan will identify the sponsoring organization and describe the relationship with other
organizations that may assist with program implementation.
Home Performance with ENERGY STAR
2-1
August 2011

-------
2.2 Metrics by Which to Gauge the Success of the
Program: Goals and Objectives
Table 1 shows the potential per home energy savings for different regions of the country. You will
want to conduct your own analysis to determine what is possible in your market.
Table 1 Potential Per Home Enei^y Savings

Census Region

Northeast
Midwest
South
West
Electricity (kWh)
1400
1700
4600
1400
Natural Gas (Therms)
400
400
200
200

Summer

Winter

Peak Demand (kW)
1.6

0.9

Typical Improvements
Increase attic insulation; insulating crawl spaces or rim
joists: duct sealing, repair and insulation; air sealing; and
installing programmable thermostat, energy-efficient heat
pump, air conditioner, furnace, boiler, lighting or windows.



2.2.1 Implementation Schedule
An implementation schedule is a useful tool for a program sponsor to prioritize activities, and assist
in planning and implementing a program. The schedule identifies, for all stakeholders, the key tasks
and when they must begin and be completed.
Table 2 shows an example schedule for implementing a HPwES program.
Home Performance with ENERGY STAR
2-2
August 2011

-------
Table 2
Example Implementation Schedule

Activity
Months in Year One
Months in Year Two
Years 3+
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
1-12
Notify ENERGY STAR of intent

























Establish advisoiy board

























Establish goals and objectives

























Perform market assessment

























Review draft plans with
ENERGYSTAR

























Select pilot/expansion
markets(s)

























Select program design/audit
tool

























Define home performance
deliveiy

























Develop contractor
recruitment Plan

























Develop results tracking
system

























Develop Marketing Plan

























Develop incentive/financing
Plan

























Develop quality assurance
Plan

























Identify/Develop Training

























Prepare implementation Plan

























Send Plan to ENERGY STAR

























Identify/recruit contractors

























Train/equip contractors

























Launch marketing campaign

























Implement quality assurance
protocols

























Implement results tracking

























Explore program expansion

























Home Performance with ENERGY STAR
2-3
August 2011

-------
2.3 A Budget Addressing Key Elements of Program
Design
Sponsoring a HPwES program is a significant commitment and requires a long-term investment of
substantial financial resources and time. Therefore, organizations should consider the costs before
making a commitment to sponsor a program. A budget will help Program Sponsors estimate what a
program will cost and how to prioritize activities based on goals and available resources.
Table 3 shows an example budget. Actual costs will vary depending on the size and scope of the
program, goals and geographic range.
Table 3 Example Budget
Budget Categoiy
Pilot Phase* Yearl
Year 2
Year 3
Year 4
Year 5
Management
$156,000
$160,000
$225,000
$242,000
$259,000
$276,000
Program Development
$52,000
$53,000




Contractor Recruitment
$65,000
$323,000
$323,000
$323,000
$323,000
$323,000
Training/Certification
$29,000
$59,000
$88,000
$88,000
$88,000
$34,000
Mentoring
$13,000
$25,000
$38,000
$38,000
$38,000
$14,000
Marketing
$78,000
$191,000
$305,000
$467,000
$627,000
$770,000
Contractor Job Incentives

$39,000
$117,000
$234,000
$351,000
$468,000
Homeowner Incentives

$216,000
$647,000
$1,295,000
$1,942,000
$2,589,000
Infield Inspections (QA)

$18,000
$40,000
$68,000
$83,000
$98,000
Evaluation
$25,000
$40,000
$40,000
$40,000
$40,000
$40,000
Total
$418,000
$1,124,000
$1,823,000
$2,795,000
$3,751,000
$4,612,000
Contractor Goal
10
31
63
94
125
136
Job Goal
0
250
750
1500
2250
3000
* Pilot Phase is typically 6 months to 1 year focused on contractor infrastructure building
Designing a HPwES program starts with defining the goals and objectives the Program Sponsor want
to achieve. Achieving energy savings from home retrofits tends to be the primary goal driving
Sponsor interest in HPwES. How much energy, and how soon it needs to be achieved will be key
questions that will direct your program design. Once you can establish how much energy you plan to
save you can break it down into more discreet objectives such as how many homes will need to be
improved? What type of improvements will achieve these results; and how many contractors will be
needed?
Home Performance with ENERGY STAR
2-4
August 2011

-------
2.4	Contractor Participation Agreement:
Recommended and Required Elements
While voluntary, participation in the program provides benefits and privileges to contractors, and
requires a commitment from the contractor to follow program requirements. In order to maintain a
good relationship with participating contractors, the expectations of both parties must be
documented in a mandatory participation agreement. This agreement will specify the contractor's
commitment to follow program requirements as well as the sponsor's obligations to the
participating contractors. There are several key areas a sponsor must address in a participation
agreement. Within these key areas, there are recommended elements by EPA (US Environmental
Protection Agency) and DOE (US Department of Energy) to bolster program oversight and quality
assurance. These key areas include:
•	Explanation of Agreement: Includes sponsor program background, and explanation of
agreement
•	Sponsor Commitments: Services and support that the program will make available to
participating contractor
•	Participating Contractor Commitments: denotes contractors agreement to play an active role in
HPwES by providing high-quality building performance services to its customers
•	Logo Usage: The Sponsor must address logo usage to ensure protection of the ENERGY STAR
brand
•	Business Practices: Sponsor must determine appropriate business practices for Participating
Contractors
Elements of the Contractor Participation Agreement are discussed in further detail in Section 3.
2.5	Marketing/Media Plan
Although many homeowners have heard of ENERGY STAR, most have not heard about Home
Performance with ENERGY STAR. Program Sponsors play a very important role in educating
consumers about the process and benefits of HPwES. The Program Sponsor's public reputation and
credibility are very valuable in persuading homeowners to consider making whole-house energy
efficiency improvements.
A marketing and media plan that explains how the Program Sponsor will promote the program to
local homeowners is essential. Even though contractors are responsible for marketing their
company and selling renovations, a program sponsor should promote the program and the value of
a whole-house approach using a variety of tactics including: advertising, public relations campaigns,
bill inserts, Web sites, media interviews, and special promotional events. The plan should include
specific examples of how HPwES will be used in sales and marketing materials and web sites.
Home Performance with ENERGY STAR
2-5
August 2011

-------
ENERGY STAR provides marketing materials such as brochures and a marketing toolkit to help
program sponsors and participating contractors educate homeowners about Home Performance
with ENERGY STAR.
An Energy Makeover Contest is a creative way to promote energy efficiency. Contest organizers
award a major energy efficiency retrofit to the winning contest participant in a highly visible
demonstration. The home, chosen for its inefficiency, produces dramatic energy savings. Because the
Energy Makeover Contest can be designed to specifically attract consumers to a whole-house
approach, it is a promising promotional tool for existing Home Performance with ENERGY STAR
programs. The contest also can be used as a tool to launch a Home Performance with ENERGY STAR
program.
2.5.1 Target Market
Every market has different challenges and opportunities that will shape the program design and
implementation strategy. An evaluation of local market conditions can provide useful background
information. This information may include:
•	Local energy issues, such as projected cost of energy, utility deregulation activities, air pollution
and energy delivery and supply capacity;
•	Coordination with other utility demand-side management (DSM) programs and incentives
•	Population and housing stock demographics, including predominant age and style of homes,
average homeowner income, average homeowner buying habits, average energy consumption
and cost-effective energy improvements;
•	Local workforce environment, including number of contractors skilled in residential energy
assessment and/or retrofit, local licensing requirements, and contractor training and education
opportunities.
After evaluating the market conditions, consider selecting one pilot location for the initial launch of
the program. Pilots typically set a goal to improve 50-100 homes. Selecting a pilot location to launch
the program can help focus available resources, allow for testing of ideas and refining the program's
design and delivery, and increase the overall likelihood of program success. Once the program has
demonstrated success in the pilot phase, consider how to increase the scale of the program and
expand to additional markets
2.6 Incentives Structure/Financing Plan
Because home performance projects typically include comprehensive renovations, costs frequently
rise above the level that homeowners are able to pay out-of-pocket. To encourage homeowners to
make improvements Program Sponsors may consider offering financial incentives or a financing
solution with an attractive interest rate.
Three general principals are recommended for any HPwES incentive plan. First, incentives are only
awarded for the completion of energy efficiency improvements recommended in a home
performance assessment by a participating contractor. Second, increase the incentive amount such
that comprehensive improvements are encouraged. One way to achieve this is to define categories of
improvements and base the incentives on the category and number of improvements completed.
Home Performance with ENERGY STAR
2-6
August 2011

-------
Third, offer incentives to both the participating contractors and the homeowners who are improving
the energy performance of their homes; this facilitates participation and retention of quality
contractors.
2.6.1	Program Design
The design of every HPwES program will be slightly different, but all programs must meet the
requirements of the Partnership Agreement (See Appendix A).
Some common program design elements include:
•	Home Performance Protocols
•	Contractor Recruitment Plan
•	Contractor Training
•	Contractor Participation Requirements
•	Marketing/Media Plan
•	Incentive/Financing Plan
•	Quality Assurance Plan
2.6.2	Home Performance Protocols
The Program Plan describes how HPwES will be delivered to homeowners. It explains how
contractors deliver a Home Performance Assessment (also called a comprehensive energy audit),
and summary report; follow best practice work standards and post-installation tests after work is
completed.
If HPwES will be delivered as a higher tier of an existing rebate or audit program or as a
replacement of a previous program, provide details on how the integration or transition will occur.
2.6.3	Contractor Recruitment Plan
A common market barrier to improving home energy performance is a limited supply of qualified
home performance contractors. Even if homeowners get recommendations from an energy audit to
improve their home, they typically don't know who is qualified to make the improvements.
Developing a strong network of professionals, skilled in whole-house assessment, diagnostic testing,
and installation best practices, is essential to a successful HPwES program.
Successful Program Sponsors have developed a contractor recruitment strategy that identifies and
recruits highly motivated and successful contractors to participate in the program. Activities may
include speaking at NARI (National Association of the Remodelers Industry), NAHB (National
Association of Builders) or ACCA (Air Conditioning Contractors of America) Chapter meetings, cold
calling reputable contractors, or hosting a Profit from Home Performance workshop to introduce the
business opportunity. Networking with utility, state, municipal, distributor, and contractor
stakeholders can help identify and recruit likely candidates.
Some Program Sponsors offer contractors incentives to participate such as discounts on training or
financing to purchase equipment. Subsidizing training, certification, or equipment will encourage
Home Performance with ENERGY STAR
2-7
August 2011

-------
contractor participation, but should be contingent on completing specific milestones, such as
passing certification tests and reporting test-out information (for completed home improvement
projects). Another idea is to provide incentives for completed jobs to encourage quality assurance
reporting. However, the incentives need to be big enough to get a contractor's attention ($100-
$300).
Sometimes a tiered incentive or caps may be appropriate so all contractors are motivated and not
just one large contractor. In some markets these incentives may not be necessary to spur contractor
participation and interest in the program. Program Sponsors should evaluate their market and
survey contractors before designing their incentive offerings.
2.7 Program Evaluation
Program Sponsors must track the number of contractors participating, the homes improved and on-
site quality assurance inspections completed. This information must be reported to EPA and DOE
quarterly for the purpose of national program evaluation. In addition, Program Sponsors are
encouraged to evaluate their program accomplishments annually and a complete a detailed review
every three years. An electronic system for reporting and tracking program results will help
streamline this process and should be developed and implemented before the program is launched
Home Performance with ENERGY STAR
2-8
August 2011

-------
2.7.1 Contractor Training
Contractor training that describes the principals of building science, how to perform energy
assessments, elements of a successful home performance contracting work practice and effective
sales techniques will all help to build and support an infrastructure of qualified contractors.
Program Sponsors need not spend resources developing training, since many local, regional and
national organizations already offer training for weatherization or home energy ratings.
Mentoring contractors on-the-job through the home performance assessment, home improvements
and test-out has become a common and valuable addition to training. Mentoring reinforces training,
helps to verify the contractor is proficient and provides an opportunity to suggest ways to
streamline the process to make quality assurance inspections efficient and productive. Mentoring is
recommended on at least 3 of the first 5 home performance jobs a contractor completes.
Sharing training and mentoring costs with participating contractors is recommended. Sponsors who
offer free training do not help to establish a sustainable training infrastructure. Instead, they
reinforce a belief that training is not a necessary business expense and set an expectation that will
be difficult to change in the future.
Some program sponsors may decide to sub-contract training, mentoring, and quality assurance
services. This is common, but program sponsors are well served to try to avoid situations where
quality assurance activities are performed by the same person that delivers training and mentoring.
Because some contractors have high employee turnover rates, contractors will need to be re-trained
periodically and successful program sponsors provide refresher courses. A continuing education
requirement is one way to reinforce training as a business expense.
2.7.2 Contractor Participation Agreement
Each section, accompanied with required and recommended elements, is detailed further in the
following table.
Home Performance with ENERGY STAR
2-9
August 2011

-------
Terms and Conditions: sets out terras and conditions under
which contractors shall participate in the program.
Participating contractors contract with property owners to
provide building performance services that are in
compliance with program requirements and standards. The
program, in return, agrees to provide technical and
marketing support for participating contractors
Termination Clause: This Agreement is completely voluntaiy and can be
terminated at any time for any reason by either Sponsor or the Participating
Contractor with prior written notice from the terminating party to the other
party.
•	The opportunity to participate in Home Performance with ENERGY STAR
training and certification by [INSERT TRAINING ORGANIZATION HERE]
•	Mentoring in the field and by e-mail and phone
•	Promotion of Participating Contractors in Program marketing
•	The opportunity to respond to leads generated from a public awareness
campaign
•	Affiliation with ENERGY STAR and access to the ENERGY STAR marketing
toolkit (if providing access to toolkit)
•	Incentives for reporting Home Performance jobs to the Program Access to
program-mandated software for building analysis and energy savings
estimation
Program Requirements: EPA / DOE requires the Sponsor to
delineate contractor program requirements. The following is
suggested wording to be included in this section; some
requirements must be addressed in the agreement, but the
wording does not need to be the exact phrasing.
Job Reporting: For eveiy Home Performance job (which
often triggers an incentive from the Program), the
Participating Contractor shall report the job following the
administrative procedures and reporting requirements of the
Program and shall provide the homeowner with a
professional report.
Field Inspections: Participating Contractor shall allow
Software: Participating Contractor shall acquire and use the Sponsor
selected software tool(s) for building analysis and energy savings estimation,
Program Referrals: Participating Contractor shall accept referrals from
Home Performance with ENERGY STAR and shall provide services to these
referral leads in accordance with Home Performance with ENERGY STAR
Contractor Participation Agreement.
Jobs Completed: To qualify for Home Performance with ENERGY STAR
incentives for certification, participation fees, equipment, and cooperative
marketing, the Participating Contractor shall, during each year of
participation, report at least [X] jobs completed, totaling [X] dollars, or
report that 20 percent of all qualifying jobs are Home Performance with
ENERGY STAR jobs.
Home Performance with ENERGY STAR
2-10
August 2011

-------
Contractor Participation Agreement
Section	Required Elements	Recommended Elements
random field inspections by the Sponsor or its designee of
work that has been performed. Participating Contractor,
upon request from Sponsor, and at no additional cost to the
customer, shall make reasonable repairs or corrections to
work that Contractor has performed to bring such work up
to Program standards.
Without written permission. Sponsor shall not employ as a
subcontractor any firm that has been suspended or
terminated from the Home Performance with ENERGY STAR
program.
Equipment Procurement: Participating Contractor must possess the
required diagnostic equipment and
Sponsor-approved software, in good working order, and have the ability to
deploy it at each participating business location prior to commencing
comprehensive energy audits and installing measures under the Program.
Subcontracting Requirements: Participating Contractor will not
subcontract for any of the services without the prior written approval of the
Sponsor/implementer and only then upon terms and conditions as
Sponsor/implementer may require for services that are incentivized by the
program.
Programmatic Changes: Sponsor reserves the right to make changes to the
Home Performance with ENERGY STAR program upon notice to
Participating Contractors. Such notification shall be by mail and posting or
through the [INSERT WEB SITE ADDRESS].
Adhering to ENERGY STAR Identity Guidelines: The
Contractor is responsible for the proper use of the ENERGY
STAR marks, as well as the proper use of the Home
Performance with ENERGY STAR marketing graphic. The
Contractor must comply with current ENERGY STAR Identity
Guidelines (available at www.energystar.gov), which
describe how the ENERGY STAR marks, marketing graphics,
and name may be used. The Contractor is responsible for
adhering to these guidelines and ensuring that its authorized
representatives, such as advertising agencies, are also in
compliance. The Sponsor will actively pursue resolution of
noncompliance related to the use of the ENERGY STAR
marks.
Promoting Whole-House Process: When using the Home
Performance with ENERGY STAR marketing graphic, it must
be used to promote a comprehensive, whole-house process
for improving the energy efficiency of homes to prevent
pollution, protect the environment, and save money on
energy bills.
Sponsor Approval of Marketing Materials: Submit all Web site designs
and marketing materials that use the Home Performance with ENERGY STAR
logo to the Sponsor for review to ensure accuracy of ENERGY STAR marks
used and consistency of the ENERGY STAR message. The Contractor will
allow a minimum of 10 full working days for review and approval of Web site
designs and marketing materials.
Advertising: When advertising or communicating to customers, the
Participating Contractor must remain in compliance with advertising
guidelines approved by the Program. Participating Contractor may not use
logos or service marks of the Sponsor. Contractors may, however, use logos
and other materials as approved by the national Home Performance with
ENERGY STAR program offered by EPA and the U.S. Department of Energy.
Participating Contractor should ask the Sponsor for guidance prior to
development and deployment of marketing and communications materials if
there is any uncertainty over compliance.
Contractor Use of ENERGY STAR Mark: Contractor should feature the
appropriate ENERGY STAR marks on the Contractor Web site and in other
promotional materials (if allowing Contractor to use the Mark).
Home Performance with ENERGY STAR
2-11
August 2011

-------
Contractor Participation Agreement
Required Elements	Recommended Elements
Section
General Business Practices: Participating Contractor shall
retain all necessaiy licensures, certifications, training, and
other requirements deemed necessaiy by state law and the
Program policies and guidelines, including all relevant
documentation pertaining to the installation of efficiency
measures. Participating Contractor will provide the
Implementer or Sponsor with access to such documentation
on request. This includes appropriate liability insurance,
permits, licensure, or certification information, and installed
equipment model and serial numbers.
Proof of Upstanding Business: Participating Contractor has the capacity to
conduct business successfully. The Participating Contractor shall provide the
program with one of the following:
A satisfactory Dun and Bradstreet Rating;
Proof of membership in the Better Business Bureau;
Verification of business capacity through at least three of the following
items:
A satisfactory banking reference. At least three satisfactory
professional/trade references, such as suppliers of material, tools or credit,
or At least three satisfactory customer references; and
Proof that the participating contractor has been in business for at least 3
years.
Waiver (if applicable): Contractors unable to meet these requirements must
submit a written Request for Waiver (requires Sponsor to develop the
appropriate form). The request must provide a detailed, reasonable, and
credible explanation of the circumstances that prevent the Contractor from
complying with one or more of the terms of the requirement. The Sponsor
reserves the right to reject any and all requests for waivers. Confirmation of
this waiver will be renewed yearly.
Warranty: Participating Contractor shall provide the customer with a
written warranty of labor and materials for a minimum of 1 year from the
date the service is performed. Equipment installed shall carry the
manufacturer's warranty, including optional extended warranty coverage.
Seeking Technical Assistance: The Participating Contractor shall
communicate openly with Program staff to seek assistance as needed in
technical or administrative areas pertaining to the Program and provide
feedback to the Program on issues pertaining to Program design or
administration, or the Participating Contractor's experiences with home
performance contracting in general.
Staff Certification: If Participating Contractor intends to
conduct home performance energy audits, the Contractor
shall maintain at least one staff member who is certified at
the (Building Performance Institute, RESNET, or equivalent)
Operating Multiple Locations (if applicable): Participating Contractor
agrees that any of its operating locations can begin participating in the
Program, under the supervision of a Program-as signed technical mentor,
when at least one staff member at the operating location seeking	
Home Performance with ENERGY STAR
2-12
August 2011

-------
Contractor Participation Agreement
Section
Required Elements
Recommended Elements

level at each participating operating location.
participation has passed the [BPI, RESNET, or equivalent] tests.

Technician Training: Participating Contractor shall ensure
that (BPI, RESNET, or equivalent) -certified technicians
receive, at minimum, training that is in compliance with (BPI,
RESNET, or equivalent certification body) continuing
education credits requirement.
Compliance with Industry Standards: While performing
any activities connected to the Program, such as home
performance energy audits, installation of measures, or
performance of post-installation diagnostic tests and
inspections. Participating Contractor shall comply with (BPI,
RESNET or equivalent) standards governing home
performance inspections, diagnostics, and treatments.
Training Availability: Participating Home Performance with ENERGY STAR
contractor recognizes that Home Performance with ENERGY STAR Program
training is available through the Sponsor program and agrees to follow the
Sponsor"s procedures and protocols. This training shall include (a) a
description of Home Performance with ENERGY STAR, (b) tips for answering
questions about Home Performance with ENERGY STAR, and (c) information
on the economical and environmental benefits of energy efficiency.
Contact Information Update: Notify the Sponsor of a change in the
designated responsible party or contacts for this agreement within 30 days.
Contractor
Representation
of Program

Misrepresentation of the Program: Participating Contractor shall not
knowingly misrepresent any information concerning the Program, its
purpose, policies, and procedures, or its role in the Program or relationship
with the Sponsor.
Program Endorsement: Participating Contractor understands that
participation in the Program does not constitute an endorsement of any kind
on the part of the Sponsor. Participating Contractor shall not state or imply
any such endorsement, either directly or indirectly.
Contractor-Sponsor Relationship: Participating Contractor shall properly
represent the relationship of the Contractor to sponsor. The Contractor shall
identify itself as an independent contractor and a qualified participant in the
Sponsor"s Home Performance with ENERGY STAR Program. Participating
Contractors shall not represent themselves as working for, or certified by,
EPA, the Sponsor, or Sponsor's affiliate, nor represent him or her self as a
Home Performance with ENERGY STAR contractor.
Voluntary
Termination
Right to Terminate: Sponsor reserves the right to terminate
this Participation Agreement at any time for cause of the
Participating Contractor's noncompliance with the Home
Performance with ENERGY STAR Program guidelines, state
laws, or this Participation Agreement.
Privilege to Participate: Participating Contractor acknowledges that
participation in this Program is a privilege, and the Sponsor may suspend or
terminate the Contractor's participation in the Program at any time and for
any reason. Failure to comply with the requirements of this Participation
Agreement or to maintain any of the standards set forth by the Program shall
Home Performance with ENERGY STAR
2-13
August 2011

-------
Contractor Participation Agreement
Section
Required Elements
Recommended Elements
constitute a reason to terminate the Participating Contractor's participation
in the program. In all cases involving a contractor's participation status or
denial of program incentives, the Sponsor's decision is final.
Right of Contractor to Terminate: In the event of a change to the
Participation Agreement, the Participating Contractor shall have the right to
terminate the Participation Agreement if the modified Participation
Agreement is unacceptable to the Participating Contractor.
Dispute Resolution: Following is some suggested wording to address
disputes that may arise between the Participating Contractor and the
Sponsor or a customer.
Authorized Representation: In the event of a dispute, each party agrees to
have an authorized representative empowered to resolve the dispute and to
meet for a period of not more than X calendar days to resolve the dispute.
Should the dispute resolution be unsuccessful, the matter may be submitted
to any court of competent jurisdiction or an alternative dispute resolution
panel. No oral or written representation made during the course of any panel
proceeding or other settlement negotiation shall constitute a party
admission.
Home Performance with ENERGY STAR
2-14
August 2011

-------
Chapter 3
HPA Summary Report (Findings and Recommendations)
Reviewing the findings with the customer is the culmination of the HPA process. This is the
opportunity to present the homeowner with the improvement opportunities discovered during the
HPA and solutions for improving the performance of the customer's home. Therefore, the
participating contractor will discuss inspection findings and present a recommended scope of work
to the homeowner.
At a minimum, the following elements are required to be included in an HPA Summary Report
provided to a homeowner after the HPA has been completed:
•	Participating contractor name, contractor contact information, and name of technician
completing the HPA.
•	Assessed home's address.
•	Date assessment was performed
•	Existing conditions:
o Air leakage visual inspection or diagnostic results.
o Insulation levels for walls, attic, rim-joists, and foundation (crawl, basement, or slab).
o Approximate age and condition of HVAC equipment (heating, cooling, and ventilation fans),
water heating equipment, and condition of exhaust flues for HVAC or water heating
equipment that consumes fossil fuel.
o Type and condition of windows and doors.
o Duct system visual inspection findings.
o Approximate age and condition of appliances.
o Any signs of moisture deposition, building performance failures or conditions affecting the
durability of the home.
o Results of tests related to the use of combustion appliances (draft, spillage, carbon
monoxide, combustion appliance zone (CAZ) depressurizationand gas leak testing).
•	A set of recommendations that is reasonably comprehensive in identifying measures that save
energy, address combustion safety, comfort, moisture deposition, indoor air quality issues,
durability or other building performance problems.
•	Recommendations in the comprehensive work scope must address air leakage between the
house and attached garage due to the potential for infiltration of carbon monoxide and other
fumes.
•	An estimate of energy savings from recommended improvements and improvement installation
cost.
The HPA summary report will include findings of existing conditions and recommendations to
improve the performance of the home. Many Program Sponsors may choose to receive this report
with the scope of work contracted by the homeowner. This review will verify:
Home Performance with ENERGY STAR
3-1
August 2011

-------
•	Compliance with HPA delivery requirements.
•	Recommendations provided to the homeowner are reasonably comprehensive and consistent
with the findings of the HPA.
•	Recommendations include an estimate of energy savings from the proposed improvements.
Note: The HPA includes the activities (i.e. inspections, tests, etc.) that are completed to assess a
home's performance, and prepare a recommended scope of work. Contractors that agree to
participate in a HPwES program need to have clear direction on what services they are expected to
deliver. Therefore, Program Sponsors will have policies and procedures explaining the minimum
requirements of the HPA. These policies and procedures are intended to establish a minimum level
of service that can be marketed to homeowners by a broad group of stakeholders. Program
Sponsors now can choose either RESNET or BPI's Audit standard - whichever one more adequately
fits its market. Included in these Energy Audit Standards is information on estimating the energy
savings and the homeowner report. The required elements of the HPA do not have to be completed
in one home visit but must be completed prior to the commencement of home improvements.
3.1	Scope of Work Review
Some programs may require a review of the scope of work before approving financing or incentives
for eligible measures. If this pre-approval is required, be aware this will add an interruption to the
contractor's sales process. As program and contractors mature, stepping back from this
requirement will give contractors more flexibility to close jobs faster.
3.2	Estimating Energy Savings
Home Performance with ENERGY STAR promotes the idea that homeowners can expect to save 20%
or more of their total energy bill by installing recommended measures that are identified during
home energy assessments. Contractors participating in HPwES need to have clear guidance on what
methods are acceptable for estimating the energy savings that will result from installing a list of
home improvements.
Fundamentally, estimating energy savings includes predicting future energy use.
Percent Energy Savings = Predicted Future Energy Use (after improvements) / Baseline Energy Use
Predicting the future is never easy. The baseline energy use in the denominator of this equation can
be either estimated or based on historical energy bills. Using a historical baseline is preferred, but
there is no way to avoid making at least one prediction (the numerator - estimated future energy
use after improvements).
Sponsors have several methods to estimate the expected energy savings of a package of
improvements. Each of these methods has advantages and disadvantages. In order to evaluate which
method may be appropriate for a specific sponsor, it is important to recognize that the estimation of
energy savings serves a variety of different stakeholder needs.
Home Performance with ENERGY STAR
3-2
August 2011

-------
3.3 Estimating Energy Use for Different Purposes
3.3.1	Aggregate Energy Savings
Utility companies, state energy offices, public service commissions, and similar entities need to
assess the impact of energy efficiency measures on an aggregate level. While it would always be
preferable to know exactly how much energy savings can be expected for every installed measure in
each individual home, such granular data may not be worth the effort to collect. For example, a
utility may need to determine how much energy was saved by its energy efficiency program after air
sealing and insulating 1,000 homes. Whether some homes saved significantly more energy than the
average and some homes saved a fraction of the average is not as critically important as what
aggregate savings were achieved. These aggregate results are more applicable to determine total
program cost-effectiveness and to estimate future demand
3.3.2	Home Specific Energy Savings
Homeowners and participating contractors need to assess the impact of energy efficiency measures
on a home-specific level. The fact that air sealing and insulating a typical home may save an average
amount of energy is not as relevant, and arguably contradicts the home performance approach of
assessing a home's unique characteristics to determine cost-effective recommendations.
Homeowners and home performance contractors typically desire to have energy estimating tools,
methods and incentive structures that identify and incentivize installed measures that are uniquely
designed for that individual home and homeowner (assuming that the programmatic reporting
burdens of using these homeowner-specific approaches don't outweigh the benefits).
3.3.3	Methods to Calculate Energy Savings
Predicting future energy use is typically achieved by utilizing mathematical models - from simple
algorithms based on rules-of-thumb or empirical data to complex physics-based whole building
simulation models.
•	Some programs will use energy-modeling software to create deemed savings databases. These
deemed savings will be generally appropriate for most measures in most houses but are not
intended to estimate specific savings of any measure in any specific house. In such cases,
contractors and homeowners may not need to use software to determine which measures may
be appropriate for the home.
•	Other programs will allow (or mandate) contractors to use energy-modeling software to
estimate energy savings that are specific to each home.
Under both approaches, energy modeling software is used - the difference is whether the energy
modeling software is being used by the program to develop the deemed savings database, or by the
contractor for each home.
Home Performance with ENERGY STAR
3-3
August 2011

-------
3.3.4
Energy Modeling to Create Deemed Savings
The Department of Energy has defined deemed savings as:
Deemed Savings. An estimate of an energy savings or energy-demand savings outcome (gross
savings) for a single unit of an installed energy-efficiency or renewable-energy measure that (1) has
been developed from data sources and analytical methods that are widely considered acceptable for
the measure and purpose, and (2) will be applied to situations other than that for which it was
developed. That is, the unit savings estimate is "deemed" to be acceptable for other applications.
Deemed savings databases have historically been built using existing measurement and verification
data. One example is the California Database for Energy Efficiency Resources (DEER). Local sponsors
have tailored these existing databases to adjust for their climate, retrofit techniques, housing stock,
and typical energy consumption in their jurisdictions. For example, Michigan recently used data
from Wisconsin and other states to create its own comprehensive database. New Hampshire has
done the same using deemed savings data from nearby New England states.
Home Performance with ENERGY STAR
3-4
August 2011

-------
Advantages:
•	Once created, deemed savings can be a simplified means to quickly estimate energy savings and
incentive levels using simple calculations. This simplicity can allow:
o Contractors to quickly sell a package of improvements and know the total incentive levels
available
o Utilities and other entities to have clear "rules of the game"
o A perceived level playing field for a public service commission (or other oversight entity) to
evaluate the impacts of different utility programs
Disadvantages:
•	Can require a significant investment of time and effort to create
•	Often require a continual process of refinement
•	Do not address homeowner and contractor needs to have home specific energy savings
calculations
•	Can create perverse incentives whereby prescribed incentive levels tied to specific measures
may make little or no impact on actual energy savings, based upon a home's characteristics and
unique needs
•	Deemed savings are often based upon an assumption that a single measure will be installed in a
home. However, when multiple measures are installed (e.g., air sealing and HVAC replacement),
the total energy savings is often less than the sum of the parts.
•	Utilities and other participants may (perhaps justifiably) create programmatic elements that
maximize energy savings based upon the features and limitations of the deemed savings
database - not building science or best practices. Imperfections in the deemed savings levels
may be amplified as a result.
•	"Pick lists" based on deemed savings tend to only identify and incentivize the most cost-effective
measures, but do not encourage deeper energy retrofits. By ignoring the cost of lost opportunity
to install multiple measures in a home, programs reliant on deemed savings may create
situations where return visits to a home are needed to install future measures that were not
initially identified as cost-effective. The commensurate overhead and transaction costs
associated with future visits are ignored
3.4 Energy Modeling Software for Use by Contractors
Many programs have relied on contractors using energy modeling software to identify cost-effective
recommendations. In most software applications, participating contractors collect a variety of data
points about the home's building shell, mechanical equipment, size, and occupants.
DOE's Weatherization Assistance Program (WAP) has approved several software programs for use
in its program. One example is the National Energy Audit Tool (NEAT). NEAT checks the
applicability of 34 building envelope, space-heating and space-cooling system, and baseload energy
efficiency measures to the specific home being audited. These measures include air and duct leakage
reduction, envelope insulation, window replacements and other treatments, space-heating and
Home Performance with ENERGY STAR
3-5
August 2011

-------
space-cooling equipment replacement and tune-up, replacement refrigerators, water heater tank
and pipe insulation, replacement lighting, and more. NEAT and other WAP approved software tools
have been developed to provide cost-effective recommendations for program administrators that
use public funds to invest in energy efficient measures.
There are a variety of software programs in the market, although most sponsors have traditionally
relied upon software that has been approved by some authoritative body, such as software
approved by DOE for weatherization work, or software determined acceptable by the mortgage
industry in the new home marketplace.
The advantages and disadvantages of using energy modeling software are varied, and may or may
not be relevant for individual software solutions. However, some important considerations that
sponsors have traditionally considered when selecting a software solution include:
•	Ease of use to train new users
•	Ease of use to enter home data into the program
•	Ability of contractor to collect the data points
o Accessibility of data (e.g., SEER rating)
o Volume of data
•	Cost
•	Quality of customer reports
•	Quality of energy savings calculations
•	Ability to incorporate historical energy usage data for the specific home
A significant issue that sponsors and contractors have confronted is the applicability of certain
software solutions for use in the existing home marketplace, and - in particular - for the specified
intent of HPwES to educate homeowners when making decisions about home energy improvements.
3.5 Actual Energy Usage
While this discussion is focused on estimating energy savings, recognition should be paid to actual
energy use after improvements are made. Post-improvement data have been used to calibrate
deemed savings tables and to enhance energy modeling algorithms. However, program sponsors
may also want to investigate how actual energy usage (post-installation) could be used to incent
homeowners. Creative strategies may be pursued using Advanced Metering devices, or using
financing vehicles.
For example, certain existing financing instruments create incentives for homeowners to pursue
deeper energy savings by offering lower interest rates for packages of improvements that save more
energy, based upon estimated energy savings using modeling software (e.g., 5% interest rate loans
for improvement packages modeled to save 20%, 4.5% interest rates for packages modeled to save
25%, etc). Programs may consider offering additional buy-downs on those interest rates if post-
installment utility bills exceed the modeled savings - such as an additional 0.5% rate cut if a home
achieves 30% savings when it was estimated to save 25%. Post-installation incentives have the two-
Home Performance with ENERGY STAR
3-6
August 2011

-------
fold advantage of 1) being real, not modeled or deemed, and 2) incentivizing homeowners to make
behavioral changes or to purchase more efficient products in the future.
3.6	Limitations of All Methods of Energy Savings
Estimations
•	Home-owner "take-back" - for example, some homeowners may decide that they can turn up
their thermostat in the winter because they can now afford to do so
•	An old refrigerator that was replaced by an energy efficient model may be moved to the
basement. Other things being equal, total energy use would go up.
•	Homeowners (and contractors) may interpret a reduction of 20% in total energy use to equate
to an equal reduction in the bills. However, the fluctuating price of energy may impact those
expectations. Generally, the 20% reduction should be viewed as a 20% reduction in total BTUs.
•	Other variables:
o	Year-to-year climate variations
o	Changes in household composition (e.g., new occupants)
o	Equipment maintenance issues (e.g., filter replacement in HVACs)
o	The simple fact that no model fully captures reality
Homeowner behavior and education remains an absolutely essential topic to address when trying to
lower energy usage. It is also beyond the scope of this section of the Sponsor Guide.
3.7	Other Energy Performance Estimations
Another factor that sponsors may consider relates to how energy modeling calculations may be used
for added value beyond the Home Performance with ENERGY STAR brand promise. The goal of
HPwES is to improve a home's performance by 20% or more by having:
•	Qualified contractors trained in building science participate in the program
•	Contractors follow best practices and common protocols to assess a home (e.g., blower door,
combustions safety testing)
•	Contractors use an acceptable method to determine estimated energy savings
•	Local sponsors facilitate the installations of recommended measures (e.g., through incentives,
education, and/or helping contractors and home energy advocates to sell improvements)
•	Contractors follow best practices and common protocols to test out a home (e.g., blower door,
combustions safety testing)
•	Local sponsors provide 3rd party oversight -100% file check and a minimum of 5% field check
(e.g., blower door, combustions safety testing, customer surveys)
The HPwES brand promise is not:
Home Performance with ENERGY STAR
3-7
August 2011

-------
•	promising that an existing home's energy use will be comparable to its neighbors, or to a new
home build to code or beyond
•	assessing how an existing home will perform under different operating assumptions (e.g., if a
new family moves into the home with different behaviors)
However, some homeowners and other entities will find value in having that knowledge. For
example, a local government that mandates a point of sale energy assessment will want to know the
inherent characteristics of a home's performance irrespective of occupant behavior - they will want
an "asset" rating, not an "operational" rating. Local sponsors should weigh the advantages and
disadvantages of including asset ratings in addition to operational ratings. The additional
informational value that asset ratings provide may or may not create potential downsides - such as
adding to the time and cost of assessments, requiring more training for participating contractors,
and confusing customers who simply want to know how specific installed measures will affect their
energy bills.
3.8 Estimating Programmatic Energy Savings
Programs may be more interested in estimating aggregate energy savings. Public Service
Commissions and other entities calculate the cost-effectiveness of programs by evaluating the
estimated energy savings generated and the costs to achieve those savings. For most utilities, these
impacts are the reason why they are considering HPwES, and they are familiar with using the terms
"cost-effective" and "energy savings" in the context of these programmatic needs. This evaluation,
monitoring and verification process serves a critical function. There are many resources available on
how to estimate energy savings and determine the cost effectiveness of programs.
•	The National Action Plan for Energy Efficiency's (NAPEE) Understanding Cost-Effectiveness of
Energy Efficiency Programs: Best Practices, Technical Methods, and Emerging Issues for Policy-
Makers fh.ttp://www,e pa.gov/cleaoeoergv/docuoieots /cost-effectiveoess.pdn.
•	The National Action Plan for Energy Efficiency's Guide for Conducting Energy Efficiency
Potential Studies http://vvvvvv-epa.gov/cleaoeoergv/docutneots/poleolial gu.ide.pdf
•	The National Action Plan for Energy Efficiency's Model Energy Efficiency Program Impact
Evaluation Guide http: //vvvvvv.epa.gov/cleaoeoergv/docuoieots/evalij.atioo guide.pdf
•	The Northeast Energy Efficiency Partnership's report, "The Need for and Approaches to
Developing Common Protocols to Measure, Verify and Report Energy Efficiency Savings in the
Northeast" http: //Meeo.org/iioloads/SOAPResources/idl88/Protocols reoort.odf
There also exists an International Performance Measurement and Verification Protocol (IPMVP).
The IPMVP is an industry-standard protocol for measuring and verifying energy savings. It is a
broad framework that outlines a flexible and broad set of measurement and verification approaches
for evaluating energy savings in buildings. Specific techniques are designed to match project costs
and savings requirements with particular efficiency measures and technologies. Each option is
applicable to different programs and projects based on factors such as the complexity of the
efficiency measures under evaluation and the risk expectations. Accordingly, each option varies in
accuracy and cost of implementation, as well as strengths and limitations.
Home Performance with ENERGY STAR
3-8
August 2011

-------
3.9 Installation of Measures
All measures should be installed by contractors following local building codes, manufacturer
specifications, and emerging industry standards and guidelines.
3.10 Inspection Results and Recommended
Improvements
3.10.1	Introduction
Homeowners who choose to invest in upgrading the energy performance and comfort of their home
are often interested in having a "Summary Certificate" that documents the improvements, as well as
the organizations and companies involved in their home performance improvement. This
"Summary Certificate" offers the homeowner proof that energy improvements have been made to
their property - which may contribute to improving the home's future re-sale value.
Local Program Sponsors who want to develop their own "Summary Certificate" must ensure that it
includes the required elements specified below and is submitted to the National Program for
approval prior to being distributed.
3.10.2	Elements of the Summary Certificate
The required elements of the "Summary Certificate" are:
•	The National HPwES logo mark and mission statement.
•	Address of home where improvements were completed.
•	Names of companies performing and verifying improvements.
•	Date of improvements completion.
•	Specific home improvements completed (e.g., attic insulation increased to R-30, SEER 14 air
conditioner installed, air sealing performed).
•	All certificates will be issued by the sponsor - not participating contractors.
Optional Elements for the Summary Certificate Include:
•	Estimated energy savings or home performance results achieved, (e.g. HERSฎ Index)
•	Estimated environmental impacts of improvements.
•	Local Program Sponsor logo mark and mission statement (if applicable).
•	Program representative signature block.
Home Performance with ENERGY STAR
3-9
August 2011

-------
Home Performance with ENERGY STARฎ
Summary of Energy Improvements Performed
Efficiency Vermont
Home Address:
OWNER NAME
Address
City. Slate. Zip
Work Performed by;
Company Name
Work Verified by:
Company Name
Work Completed on:
Month 00. Yea-
Program ReproscniaBvo (Sipiaturc Osxonalj
Home Performance Improvements:
(Sample List)
ซAir Sealing Pelormed
•Attic Insulation Increasec to R-30
•	Wall Insulation Acded
•	Djcts Sealed
•	Seer 14 Air Conditioning Installed
•	90% AFUE Furnace Installed
•	High-Performance Windows Installed
•	ENERGY STAR Qualified Dishwasher and
Refrigerate- Installed
•	5 ENERCY STAR Qualified CFLs Installed
Environmental Impact of Improvements:
(Optional)
•	CO; Emissions recused by; 13GQ lbs
Home Performance Results Achieved:
(Optional}
•	Home energy use before improvements
•	Home energy use after improvements (estimated)
Home Performance with ENERGY STAff offers a comprehensive, whole-house approach to home
improvement that results in better energy efficiency, greater comfort and lower energy bills.
ENERGY STAR is a voluntary partnership sponsored by the U.S. EPA and U.S. DOE to protect tfie
environment through superior enerjy efficiency.
HOME PERFORMANCE WITH
ENERGY STAR

-------
3.11 Post-installation Test or "Test-out" Protocols
3.11.1	Introduction
One of the features that distinguish HPwES as a value-added service for residential customers is the
series of instrumented tests and inspections that the home performance contractor performs after
the improvements have been made to a home. These tests support the "do-no-harm" principal
which is a hallmark of home performance contracting. While there is no guarantee that any home
will operate safely under all conditions, the home performance contractor is uniquely concerned
about health and safety of the occupants. In addition to addressing health and safety issues that may
be directly affected by the home performance work, some of the tests provide valuable information
on the effectiveness of air and duct sealing measures installed.
3.11.2	Program Oversight of Post Installation or "Test-out"
Requirements
To ensure that the "test-out" is performed adequately by participating contractors, Program
Sponsors need to adopt "test-out" requirements in their program policies and procedures that meet
or exceed the guidance in this document. The following guidance and test-out template are offered
to assist Program Sponsors with the development of their "test-out" procedures. When a
participating contractor completes home performance improvements for a customer, they will
perform the post-installation tests and inspections described in this section, and enter the results in
a "Post-Installation Tests and Inspections" Form (the National Program offers a template form that
can be used or modified by Program Sponsors). If any of the tests or inspections show the need for
corrective action, the contractor can record the action item(s) in the document or postpone
completing the Form (including having the customer sign it) until those corrective actions have been
made.
Home Performance with ENERGY STAR
3-11
August 2011

-------
Chapter 4
Quality Assurance Plan
4.1 Introduction
Quality assurance is an essential component of Home Performance with ENERGY STAR and a
program sponsor is responsible for developing and implementing a Quality Assurance Plan. Quality
assurance protects homeowners by providing an independent review of the work performed by
participating contractors to ensure that it meet program standards. Quality assurance also protects
the reputation of the Program Sponsor.
The Program Sponsor must identify who will be responsible for quality assurance and provide clear
direction on what activities they are expected to complete. Protocols that need to be defined include:
•	Job Reporting Review (file review)
•	On-field inspection
•	Customer Feedback
•	Contractor Feedback and Corrective Actions
In accordance with the terms and conditions of using the ENERGY STAR logo mark, and to maintain
HPwES's reputation for quality and value all Program Sponsors are required to implement a QA
plan. This plan will include strategies to ensure that participating contractors are qualified and that
completed improvements meet program standards. QA plans will explain:
•	Reporting process that requires participating contractors to report jobs that are promoted to
homeowners and performed under the HPwES program.
•	Job report review process that ensures program compliance and provides for follow-up with
the contractor when necessary.
•	Customer feedback mechanism which allows customers to provide feedback directly to the
Program Sponsor.
•	On-site inspection protocols including a sampling rate set at a minimum of 5% (1 in every 20
Jobs) for all participating contractors.
•	Conflict resolution mechanism for responding to and resolving customer complaints.
•	Record keeping and tracking of results from on-site inspections, customer surveys, and
corrective actions. Records must be available for review upon request from the National HPwES
Program.
Home Performance with ENERGY STAR
4-1
August 2011

-------
4.2	Required Elements
Program Sponsors are required to implement a QA program that evaluates whether participating
contractors have:
•	Performed a HPA and made comprehensive recommendations for improving the performance of
the home.
•	Installed improvements which will reduce energy use in the home, improve comfort, or address
specific building performance problems, such as failures on combustion tests.
•	Satisfactorily completed the contracted scope of work.
•	Performed required diagnostic tests and inspections upon completing the improvements.
4.3	Job Reporting Review
This guidance has been developed to help clarify the job report review process and provide
recommendations for Program Sponsors to consider while developing program policies. While the
Program Sponsor may choose to consolidate reporting of all information into one submittal, this
section describes the report review process as three separate document reviews which are
supplemented by a periodic review of a contractors performance history across a period of time. An
example of questions to be answered during the job report review process is in Section 4.4.
This guidance has been divided into the following areas:
•	HPA Summary Report (Findings and Recommendations).
•	Scope of Work Review.
•	Test-out Report Review.
4.3.1 Optional Report Review Process
The required paperwork reporting associated with completed jobs may be reported to the Program
Sponsor at set intervals or at the completion of the job. Providing incentives to encourage
contractor reporting is recommended.
Home Performance with ENERGY STAR
4-2
August 2011

-------
4.4 Example Job Report Review Evaluation
4.4.1 HPA Summary Report Review
Ml' \ Summ;ir\ Ucpoil Ri*\ ii*\\
W-s
No
All required diagnostic tests have been performed and information provided is consistent
with program policies and procedures.


Findings reflect strong adherence to the technical guidelines and local program
requirements


Combustion equipment tests have been completed and appropriate recommendations
have been made to mitigate any failures in the


Recommendations are comprehensive and consistent with program policies and
procedures and with HPA findings


Estimated savings for proposed improvements have been provided as part of the
summary report


Notes:


4.4.1.1	Scope of Work Review
fionlr;icl Scope ol Work ol Conlmcl Ue\ irw
W-s
No
Any findings of combustion safety issues have been included and addressed in the scope
of work


The scope of work is consistent with the recommendations in the HPA Summary Report
and program policies (cost effectiveness or allowed measures and installation
specifications).


The scope of work is comprehensive in nature and includes the replacement of more than
one system (e.g. Not just an HVAC replacement or window replacement job)


Notes:


Home Performance with ENERGY STAR
4-3
August 2011

-------
4.4.2 Test-out Report Review
Ti'Sl-nul lirpnrl ltf\ ir\\
W-s
No
All appropriate post diagnostic and visual inspections have been recorded per the
contracted scope of work.


All installed measures in the contracted scope of work have been verified as installed.


Airflow tests have been completed on the HVAC system if work on ducts or an HVAC
system was replaced in the scope of work. Is the airflow within the acceptable range?
Refrigerant charge was check for AC or HP replacements


Combustion equipment testing and combustion appliance zone testing has been
completed and results recorded. No corrective action is needed based on results


Building air- tightness standards have been calculated and appropriate recommendations
for ventilation or required corrective action has been installed


The contractor and customer have signed the test-out reporting form attesting to the
completeness of work


Notes:


4.4.3 Example On-site Inspection Scoring Methodology
The following is a proposed methodology to use during on-site inspection to evaluate a contractor's
work or can be used by Program Sponsors to design their own scoring methodology. The scoring
tables below provide a conceptual basis for a programmatic scoring system that would be based
substantially on a Program Sponsor's adopted technical standards.
In this example a contractor would receive the lowest score for which they received a "Yes" on an
inspection finding. The scoring protocol presents a set of statements that characterize a
contractor's work performance. The inspector would begin with the first set (Score 0) and answer
each question either "Yes" or "No". If the contractor receives a "Yes" answer to any question, they
receive a score of 0. If not, they proceed to the next set of questions and repeat the process. The
scoring is on a scale of 0 to 4, with the 0-2 scores in the "Fail" range and 3-4 in the "Pass" range.
Score: 0 - Contractor's performance does not meet technical standards or program requirements
and the home requires immediate corrective action:
Home Performance with ENERGY STAR
4-4
August 2011

-------
un-silc Inspci-lion riinliiii>s
W-s
No
Combustion appliance lesling (including carbon monoxide lesl, drafl measuremenl,
spillage evaluation, and worse-case depressurization of combustion appliance zone)
results do not meet BPI Technical Standards or relevant equivalent program standard


Measures in contracted scope of work not installed (e.g. attic insulation not installed or
duct sealing work not completed)


Minimum standards for building ventilation are not being met (e.g. BPI Technical
Standards)


Unsafe conditions resulting from installed work and posing an immediate risk to
occupants are found (e.g. greater than 35 ppm recording during combustion appliance
testing)


Notes:


Score: 1 - Contractor's performance does not meet technical standards or program requirements
and the home requires corrective action:
()n-sili' InspiTlion rimlin**s
W-s
No
Serious moisture issues have gone unaddressed and have no I been included in
recommendations per Program Sponsor requirements


Health and safety issues present, but do not pose an immediate risk to occupants


Measures were not installed correctly (Airflow or refrigerant charge associated with a
new AC system does not meet program requirements (e.g. ACCA HVAC QI Specification or
BPI Technical Standards)


Customer did not receive HPA report or did not receive comprehensive recommendations


Notes:


Score: 2 - Contractor's performance meets all combustion safety requirements but several technical
deficiencies were observed that require corrective action:
Home Performance with ENERGY STAR
4-5
August 2011

-------
un-silc Inspci-lion riinliiii>s
W-s
No
Below standard installation of'insulation (e.g. signilicanl gaps or voids in installation of
attic insulation or attic insulation levels do not meet specifications in the contracted scope
of work)


Air sealing work did not address significant pathways for infiltration (e.g. large attic
bypasses into the living space around duct work penetrations, dropped soffits ceilings,
etc...)


Windows installed did not meet program requirements (e.g. specified performance for u-
value and solar heat gain co-efficient)


Garage to living space leakage found and not addressed in the HPA findings and
recommendations nor the scope of work


HVAC equipment not installed to program guidelines or not operating properly (e.g. flame
interference found in gas furnace, indoor evaporator coil not matched to the outdoor coil
for AC system replacement, or furnace temperature rise test not within manufacturer
specified range)


Recommended measures on HPA report were not comprehensive; inspection found
several cost effective improvements that were not recommended to the customer (e.g.
blower door test results indicate considerable opportunities for air sealing that were not
included in HPA findings and recommendations)


Test-out reporting does not match on-site QA inspection (inaccurate testing results)


Notes:


Score: 3 - Contractor's performance meets all technical standards and program requirements but
some areas of technical performance need improvement and may require corrective action:
Home Performance with ENERGY STAR
4-6
August 2011

-------
un-silc Inspection I'inilinns
W-s
No
Installed measures did nol meel all lechnical installation standards, but no serious
deficiencies and contractor corrected items, (e.g. use of sealant on ductwork that does not
meet UL 181, UL 181A, or UL 181B)


Some incorrect data gathered and provided to customer but with no significant impacts
on the work completed or effectiveness of the job


Recommendations in customer report are fairly, but not completely comprehensive (e.g.
did not address minor moisture issues like downspout extensions or some air sealing
opportunities were missed)


Notes:


Score: 4 - Contractor's performance meets all technical standards and program requirements
On-site Inspect inn rimlini>s
W-s
No
All technical standards for installation have been met (e.g. BPI Technical Standards)


Work comprehensive in nature, and high priority items have been installed.


Recommended and installed measures were consistent with program requirements;
work not performed was by customer decision


Test-out reporting verified to be accurate


Notes:


4.5 Test-out Report Review
4.5.1 Optional Report Review Process
4.5.1.1	Summary and Trends Review
It is recommended that Program Sponsors not only look for clear examples of noncompliance, but
also look for patterns of potential non-compliance over many jobs (for instance, a heating contractor
demonstrating a habit of failing to recommend attic insulation in the Homeowner Summary Report).
For this reason, it is recommended that all reviews be tracked and trend analysis be completed
quarterly.
The review of test-out information must be included in the report review process. This is a review of
all required post-completion test-out data and will include a customer's signature signifying that the
Home Performance with ENERGY STAR
4-7
August 2011

-------
work is complete (and meets their reasonable expectations). The test-out report may be compared
to the contracted scope of work and other pre-installation reporting data for consistency and
accuracy of the completed job. The HPA findings, test-out report and installed measures will
provide the basis for the on-site QA inspections. If corrective action is needed, based on results of
an on-site QA inspection, then an additional test-out report will be submitted to document the
corrective action completed with a customer signature.
4.5.1.2	Follow-up
If reviews indicate that a contractor's reported jobs do not meet program policies and procedures
then the Program Sponsor will consider conducting an on-site inspection on the job being reported.
4.6 On-site Inspection Protocols
Local Program Sponsors' QA protocols are required to explain how on-site inspections will be
conducted. The on-site inspections will be delivered by individuals that meet or exceed the local
program's minimum technical requirements for a participating contractor. DOE is currently drafting
new protocols to define practical on site inspection procedures.
The protocols for performing on-site inspections have been divided into the following areas:
•	Job Selection Protocol
•	Customer Discussion
•	Visual Inspection and Diagnostic Tests
•	Contractor Performance Record
•	Inspection Documentation
4.7 Job Selection Protocol
Program Sponsors are required to perform on-site inspections at a minimum sampling rate of 5% on
each participating contractor's completed jobs. Please note that onsite inspections are at the
contractor level and not 5% of total program jobs. On-site inspections focus on evaluating a
participating contractor's ability to perform a HPA, develop a scope of work of eligible
improvements, and properly install the improvements selected by the customer.
Jobs will be selected through a random sample in order to obtain a representative sample of each
contractors work. However, the sample is not expected to be purely random. Some homeowners
will not be willing to schedule the inspection; other customers may request an inspection due to
issues or concerns about the work performed; and some inspections may be conducted as a result of
issues raised in the job report review process.
Home Performance with ENERGY STAR
4-8
August 2011

-------
Optional Tiered Sampling Rate
It is recommended that a greater sampling rate be applied to participating contractors who are new to
the program and/or are not fully meeting program requirements. The following is an example of a
tiered approach to sampling rates for on-site inspections:
Tier 1 In-field inspection or mentoring on 3 of the first 5 jobs completed by a new contractor
participant.
Tier 2 After the first 5 jobs are completed, 20% of the next 20 jobs would receive in-field inspections.
Tier 3 After completion of their first 25jobs, the Program Sponsor would begin inspecting jobs at a
lower sampling rate while maintaining an overall rate that is above or equal to 5% of total completed
jobs (minimum required sampling rate).
The specific sampling rate can vary as long as overall a 5% inspection rate is maintained. In this tiered
approach, a Program Sponsor would typically not reduce a contractor's inspection rate until the
contractor is making satisfactory progress to ward meeting program standards. For example, a
Program Sponsor may use the Tier 1 sampling rate for a new contractor beyond the contractor's first
five jobs if the initial in-field inspections indicate significant difficulties in meeting program
requirements.
All on-site job inspections will occur after improvements have been installed. However, the on-site
inspection may be scheduled during the contractor's test-out and prior to the job completion being
reported to the Program Sponsor. On-site inspections will be made on a continuous basis and not
completed in bulk (e.g., do not wait until a contractor has completed their first 20 jobs to start
performing on-site inspections). Contractors with multiple offices or locations across wide
geographic areas will be treated as separate participants for the purpose of determining their on-
site inspection rate.
4.8 Visual Inspections and Diagnostic Tests
After completing the introductory discussion with the customer, the inspector will begin the
required visual and diagnostic inspection. The visual and diagnostic inspections are derived from
HPA requirements and required test-out diagnostic tests and inspections based on the installed
scope of work (see Section 3.11.2 of this Guide).
The following list describes the areas the inspector will examine:
•	Obvious missed opportunities for improving home performance that were not reflected in the
HPA findings and recommendations.
•	Proper installation of measures installed by the contractor.
•	Verify test-out inspections and diagnostic results completed by the participating contractor.
Results of these visual and diagnostic inspections will be compared to the documentation (HPA
summary report, recommended improvements, installed improvements, and test-out data) reported
to the program by the contractor to evaluate their performance.
The inspector will not make judgments about the contractor's professional integrity or service to the
customer. Any communication about the contractor's performance will always follow program
protocols for contractor feedback and corrective action.
Home Performance with ENERGY STAR
4-9
August 2011

-------
4.9 Customer Discussion
It is required that the on-site inspection begins with the inspector (acting on behalf of the Program
Sponsor) introducing themselves, their organization affiliation, and their purpose: to verify the
work meets program guidelines. The inspector should address any questions that the customer has
about the inspection and determine if the customer has any specific concerns about the installed
work. However, it is very important the inspector present a positive and objective attitude during
all conversations with the homeowner.
Optional Customer Discussion Items
The inspector may interview the customer about their experience with their home performance
consultant and/or contractor to gain valuable insights that may enhance the program. This
discussion could include:
•	Verifying that the customer received program information explaining the HPA process and
what to expect from the program (if providing this program information is required by
program.
•	Confirming that the customer received an HPA report and recommendations for
comprehensive improvements.
•	Verifying the important pre-existing conditions (if appropriate) and installation of contracted
measures.
•	Verifying who installed the measures and when the improvements were completed.
•	Inquiring as to whether the customer has utility bill data available, if the utility bills were
requested by the contractor and, if so, whether the customer provided the utility bills to the
contractor.
•	Verifying completion of diagnostic test(s) before and after installation of measures (e.g. blower
door test prior to beginning installation of shell measures and again after they were complete).
•	Discussing the customer's satisfaction with: the participating contractor's assessment, the
installation; and their overall experience with the HPwES program.
•	Encouraging customers to refer friends and family to the program.
4.10 Contractor Performance Record
It is required that the performance of contractors be evaluated as part of the on-site inspection
process. Program Sponsors are required to develop a methodology for tracking a contractor's
performance across their completed jobs. This methodology will be explained in the Program
Sponsor's implementation plan.
Home Performance with ENERGY STAR
4-10
August 2011

-------
Optional Contractor Performance Methodology
Scoring Protocol
A scoring methodology may be helpful to document a contractor's performance history, provide
contractor feedback, and provide an objective basis for increasing the on-site inspection rate or
removing a contractor from HPwES program. Program Sponsors may develop a scoring protocol
and submit to EPA and DOE as part of their implementation plan. An example of a job scoring
protocol is in Section 4.4.3 of this guide.
4.11 Customer Feedback
Receiving direct feedback from homeowners (participating contractor customers) is an important
part of a HPwES QA program. Local Program Sponsors are required to have a mechanism for
customers to provide feedback. Direct customer feedback can reduce risks and costs by helping to:
•	Determine customer satisfaction.
•	Check for program compliance.
•	Identify high performing and low performing contractors.
•	Focus marketing efforts.
Optional Elements for Receiving Customer Feedback
The National HPwES Program recommends the use of customer surveys as the principle means for
collecting customer feedback. The local Program Sponsor can use these guiding principles when
developing a customer survey or other customer feedback mechanism:
•	Survey should be short and easy to do (5-10 questions maximum).
•	Survey should be done routinely on every job or on an established sampling interval.
•	Survey should be sent or performed directly by the Program Sponsor or independent
representative.
•	Survey should be sent directly back to the Program Sponsor or independent representative.
•	Survey should include, at a minimum, questions on the following topics:
o Customer satisfaction with the quality of the work done.
o Was a HPA performed at the beginning of the job?
o Customer satisfaction with the contractor who did the HPA and those who did the work,
o How the customer found out about the HPwES Program.
•	Survey should be anonymous, but allow the customer to provide contact information.
•	Survey should include information on how to contact the program sponsor for additional
feedback (phone number and/or e-mail).
•	Survey results should be saved, compiled, and analyzed on a routine periodic basis.
Home Performance with ENERGY STAR
4-11
August 2011

-------
For the best survey success (highest return rate), customers should be actively asked to provide
feedback. This can be done by several methods:
•	Calling customers to do the survey over the phone.
•	Directly mailing or e-mailing customers the survey.
•	Completing the survey during on-site inspections.
4.12	Contractor Follow-up
If either positive or negative feedback is received from a customer, that information will be recorded
as part of a contractor's performance history. An on-site inspection will be scheduled if customer
feedback warrants additional investigation to verify that the contractor is meeting program policies
and procedures.
4.13	Contractor Feedback and Corrective Actions
This QA component of the HPwES program serves a dual purpose: first to ensure that contractors
are meeting all program guidelines and technical standards and second to provide a mechanism for
constructive feedback intended to improve their diagnostic capabilities, comprehensiveness and
quality of work and customer relations. Contractor feedback is a key to maximizing program
benefits, ensuring their persistence over time and providing a pathway to successful market
transformation. Since HPwES programs are voluntary, it is recommended that QA communications
be delivered in a positive spirit of assistance, education and continuous improvement.
Providing feedback to contractors on delivering effective HPA's, following technical standards, and
installing improvements using best practices can be the most important and valuable service that a
Program Sponsor can provide to new participating contractors. For this reason, it has been
recommended to have a tiered sampling rate to assist new participants.
At the same time, contractor feedback on performance ensures a "level playing field" for all
participating contractors, a feature that can be critical to retaining them as program participants, as
well as critical brand protection for the National Program and local Program Sponsor.
Program Sponsors will formalize a process for managing contractors that do not meet program
policies and procedures. This process will be clearly explained in a contractor participation
agreement. When issues are discovered as a result of job reporting reviews, customer surveys,
customer inquiries and concerns, or on-site inspections the first step is to contact the contractor and
try to resolve the issue in a positive way. Because issues can not always be resolved in a
constructive way it is best to document all QA findings and inform participating contractors of any
significant or serious deficiencies and any corrective actions that need to be taken immediately.
Examples of program job report review evaluation forms, on-site inspection scoring forms.
A Program Sponsor's process for evaluating and managing contractor performance will include the
following:
•	Written field reports followed by contractor performance feedback discussion.
•	If required, corrective action work scopes and completion verification.
Home Performance with ENERGY STAR
4-12
August 2011

-------
•	Written notification of recurring, systematic or otherwise serious non-compliance with program
policies, standards behavior or applicable laws or regulations.
•	Provisions for disciplinary action, such as probation or suspension.
Optional Corrective Actions
Re-training and Mentoring
If contractor performance fails repeatedly, it is recommended that the program consider
additional program action beyond the corrective action measures in the home. Additional
training or job mentoring can be offered or required to address the deficiencies in performance,
if deemed necessary by the QA inspector.
Increased On-site Inspection Rate
It is also recommended that the program increase the on-site QA inspection sampling rate until
the contractor demonstrates improvement.
• Provisions for contractor to appeal a disciplinary action.
Maintaining the integrity of the program should be a Program Sponsors primary concern.
Therefore, contractors who consistently fail to follow program policies and procedures, or existing
laws and regulations should be removed from the HPwES Program. If this situation occurs Program
Sponsors are strongly encouraged to make a good faith effort to work with the contractor to
overcome any shortcomings confidentially. If a contractor is removed from the HPwES Program, the
Program Sponsor must notify EPA and DOE of the action.
And for those contractors who participate fully and perform over 100 jobs in a calendar year,
EPA/DOE will recognize them formally with as a Century Club award winner. Sponsors must
approve that contractors are in good standing and have met all programmatic QA rigors.
4.14 Example Contractor Feedback and Corrective
Action Levels
The following list shows five potential scenarios from the QA process and contractor feedback
and/or corrective actions that could be taken:
1.	If there are no deficiencies in performance found and the contractor has provided
comprehensive recommendations, fulfilled the work scope, and installed measures that meet all
technical standards, it is recommended that the program provide positive feedback to the
contractor on their performance. Exemplary performance should also be documented and, if
consistent, it is suggested that contractors be recognized for their contributions to the program.
2.	If the customer is satisfied with the work, program and technical standards have generally been
met, but there are relatively minor deficiencies or opportunities to improve a contractor's
performance such as a non-comprehensive set of recommendations in the homeowner report,
evidence of repeatedly non-comprehensive job scopes (suggesting a lack of desire or success in
selling comprehensive work) or an indication of minor inaccuracies in tests performed, then
constructive feedback should be provided to the Contractor. This feedback would encourage
Home Performance with ENERGY STAR
4-13
August 2011

-------
performance improvement in the future and to reinforce positive aspects of their job
performance.
3.	If the customer is satisfied with the work and program standards have generally been met, but
deficiencies are present in the completeness, compliance with the contract or quality of the
work performed, the QA inspector is required to contact the Contractor to discuss findings and
corrective actions to be taken. The QA inspector will provide a work scope of corrective actions
to the contractor and require the contractor to correct deficiencies within a specific period of
time (recommended to not exceed 30 days). Contractor is required to provide written
documentation with the customer's signature after completing the corrective actions. Program
evaluates whether additional training or job mentoring is necessary to improve the contractor's
performance and a higher on-site inspection rate is applied to future jobs.
4.	If the customer is dissatisfied and the QA inspector verifies that deficiencies are present but are
not an immediate health or safety threat to the home's occupants, the QA inspector is required
to document findings and contact the Contractor / Field Supervisor to discuss the findings and
corrective actions that will be taken. The QA inspector will provide a list of corrective actions to
the contractor and require the contractor to correct deficiencies within a specific period of time
(recommended to not exceed 30 days). Contractor is required to provide written
documentation with the customer's signature after completing the corrective actions. The
program evaluates whether additional training or job mentoring is necessary to improve the
contractor's performance and a higher on-site inspection rate is applied to future jobs.
5.	If any serious condition is found through the QA process (typically on-site inspection) that must
be addressed immediately because of imminent health and safety threats, it is required that the
QA inspector contact the contractor without delay and inform the homeowner of the condition.
The QA inspector will take remedial action, as appropriate, which may include educating the
homeowner, calling the fire department, or shutting off appliances. The QA inspector will
ensure to the maximum extent possible that the condition has been addressed in the short term
and provide the contractor with a list of corrective actions. The contractor will provide the
program with written documentation that the customer has signed, to verify completion of the
corrective actions. Program evaluates whether additional training or job mentoring is necessary
to improve the contractor's performance and a higher on-site inspection rate is applied to future
jobs.
Home Performance with ENERGY STAR
4-14
August 2011

-------
4.15 Inspection Documentation
Program Sponsors are required to keep a record of all inspections performed including on-site QA
inspection form(s), and any follow-up actions with the contractor and/or customer. Program
Sponsors will document:
•	On-site inspection report including contractor performance (e.g. scoring protocol).
•	Follow-up with contractor, if required. This includes a record of any remedial actions, such as
corrective measures in the home by the contractor; assignment of program technical or
administrative assistance to address a particular contractor need; or, in more serious cases,
program disciplinary actions. If corrective measures in the home are requested and installed,
the program must receive additional documentation with appropriate test-out information and
a customer signature.
4.16 Program Data Reporting Requirements
For data reporting you will use the Contractor Job and Reporting Tracking spreadsheet. This is an
Excel spreadsheet specific to your sponsorship for providing EPA/DOE with your participating
Contractors and corresponding performance numbers. If your internal tracking mechanisms make
it difficult to use this particular format, please suggest alternatives.
• Request a
4.17 Your Contractors
Utilize the Tracking Spreadsheet to:
1.	Associate participating Contractors with your sponsorship.
2.	Request My ENERGY STAR Account (MESA) including marketing resources access for
participating Contractors.
3.	Update participating Contractor information as needed.
To use the Tracking Spreadsheet:
• Enroll participating organizations/Contractors:
o Add a row in the spreadsheet,
o Enter the organization/contact information.
• Needed information includes:
o Organization name
o Contractor first and last name
o Contractor email
Home Performance with ENERGY STAR
4-15
August 2011

-------
o	Contractor phone (can be the same as organization phone)
o	Organization address
o	Organization phone
o	Organization fax (if applicable)
o	Organization website (if applicable)
Please note that Contractors cannot receive access to MESA and its resources without a valid email
address.
•	Provide your completed spreadsheet to the HPwES team
o Email your spreadsheet to homeperformance@energystar.gov
o The HPwES team will update EPA's records to associate the Contractors with your
sponsorship as well as grant MESA access.
•	Future changes in information
o Make the change within the appropriate cell in the spreadsheet
o Highlight those cells in green that you have added/updated information.
o Highlight cells in red when a Contractor is no longer participating in your sponsorship and
MESA access needs to be removed.
o Email your updated spreadsheet to homeperformance@energystar.gov
4.18 Quarterly Reporting
Utilize the Tracking Spreadsheet to:
1. Provide reporting numbers on completed jobs and quality assurance inspections. Note: A
completed job is one in which a test-in was performed, improvements/work was performed,
and a test-out was performed.
Please provide the contact information for the individual who is responsible for quarterly
reporting. Some sponsors designate an employee, while other sponsors designate an
employee of an implementation contractor. Providing quarterly reports is one of the most
critical and fundamental metrics by which we track program success.
To use the Tracking Spreadsheet:
• Add reporting numbers:
o Enter the job and quality assurance numbers that the organization completed per quarter.
•	If there are multiple Contractors listed under one organization, list the quarterly
numbers under the primary contact for that organization.
•	If an organization has had no activity, leave the field cell empty,
o Report numbers on a quarterly basis.
Home Performance with ENERGY STAR
4-16
August 2011

-------
•	Report numbers in January to cover activity in October, November, and December.
•	Report numbers in April to cover activity in January, February, and March.
•	Report numbers in July to cover activity in April, May, and June.
•	Report numbers in October to cover activity in July, August, and September,
o Email your updated Tracking Spreadsheet to homeperformance@energystar.gov.
Once reviewed and recorded, a confirmation email will be sent with an approved Spreadsheet to use
for next quarter.
4.19	Annual Summary
Summary reports are due from all partners by December 15th. They should not exceed three pages,
but should include an annual summary of contractor recruitment/training activities; quality
assurance activities; marketing activities; and future program plans. Applications for ENERGY STAR
Partner of the Year Awards can fulfill this obligation (see Section E). Unless otherwise requested,
the annual summaries will be posted on our Sponsor Locator page inside the HPwES EPA website.
4.20	Active Status Requirements
ENERGY STAR is a partnership in which all program sponsors voluntarily agreed to report quarterly
the number of completed jobs and completed quality assurance inspections. Quarterly reporting
allows us to track program success, identify inactive partners, give newly participating contractors
access to the resources on MESA, and recognize Century Club contractors. Without this information
we are not able to recognize your program's achievement.
If a program does not report jobs on time, the program will be considered inactive. Home
Performance with ENERGY STAR may attempt to contact the designated point of contact for
maintaining the Tracking Spreadsheet or others in the sponsoring organization, but these outreach
efforts are a courtesy to the sponsor and are not a precondition to listing an organization as inactive.
Once inactive, an organization will be removed from the ENERGY STAR website, and it must cease
using the Home Performance with ENERGY STAR mark in print and on its website.
Home Performance with ENERGY STAR
4-17
August 2011

-------
Appendix A
HPwES Partnership Agreement

-------
OMB Control No. 2060-0586
Program Sponsor Partnership Agreement For
Home Performance with ENERGY STARฎ
HOME
PERFORMANCE
WITH
ENERGYSTAR
Return this form to ENERGY STAR:
H om e Perf orman ce@ En ergyStar. gov
US EPA (Mail Code 6202J}
1200 Pennsylvania Ave, NW
Washington, DC 20460
FAX: 202-343-2200
Eligible Organizations: Organizations that implement a residential home improvement program that
meets the criteria for Home Performance with ENERGY STAR, a joint U.S. Environmental Protection
Agency and U.S. Department of Energy program.
Through this agreement, ENERGY STAR and	
(hereafter "the Partner") agrees to work in cooperation to promote Home Performance with ENERGY
STAR under the program name	(hereafter "the program").
Organization Name: 	
Contact Name: 	Email:	
Address: 	 City/State/Zip:	
Telephone: 	 Fax:	 WebSite:	
Major Metro Area(s) Served: 	
Partner Commitments
The following are the terms of the ENERGY STAR Partnership Agreement for Home Performance with ENERGY STAR
(HPwES) Program Sponsors. Guidance on this agreement is available at: www.energystar.gov/hpwessponsors.
A. ENERGY STAR Brand Requirements -The partner agrees to comply with ENERGY STAR branding requirements
1.	Comply with current ENERGY STAR Identity Guidelines, (available at www.eneravstar.aov) which describe how
the ENERGY STAR marks, marketing graphics, and name may be used. The Partner is responsible for adhering
to these guidelines and for ensuring that its authorized representatives, such as implementation contractors,
advertising agencies, and participating contractors are also in compliance. In order for the Partner to ensure
compliance, the Partner must maintain a current list of authorized representatives which ENERGY STAR may
request to verify compliance.
2.	The Partner is responsible for the proper use of the ENERGY STAR marks, as well as the proper use of the
Home Performance with ENERGY STAR marketing graphic used by participating program contractors.
3.	Feature the appropriate ENERGY STAR marks(s) on Partner's Web site and in other promotional materials. To
link to the Partner on the ENERGY STAR web site, the Partner must first comply with the ENERGY STAR Web
Linking Policy found on the ENERGY STAR Web site.
4.	Submit all Web site designs, and marketing materials, developed for the Partner's Home Performance with
ENERGY STAR promotions to ENERGY STAR (using the address listed above) for review to ensure accuracy of
ENERGY STAR marks used and consistency of the ENERGY STAR message. The Partner will allow a minimum
of five full working days for ENERGY STAR to review and approve Web site designs and marketing materials.
5.	Provide Home Performance with ENERGY STAR training to all employees who provide customer service. This
training shall include: a) a description of Home Performance with ENERGY STAR, b) tips for answering
questions about Home Performance with ENERGY STAR, and c) information on the economical and
environmental benefits of energy efficiency.
6.	Notify ENERGY STAR (using the address listed above) of a change in the designated responsible party or
contacts for this agreement within 30 days.
EPA Form 5900-17	1 of 4	2/16/2011
The government estimates the average time needed to fill out this form is 1.25 hours and welcomes suggestions for reducing this effort. Send comments (referencing OMB Control Number) to the Director, Collection Strategies
Division, U.S. EPA (2822T), 1200 Pennsylvania Ave., NW, Washington, D.C. 20460.
as follows:

-------
OMB Control No. 2060-0586
B.	Program Plan Requirements - The Partner agrees to develop and submit a Program Plan to HPwES as follows:
1.	Develop and submit a program plan to implement HPwES using the Program Plan Guidance available at
www.energystar.gov/hpwessponsors.
2.	After the Partner submits a program plan along with a signed Partnership Agreement, ENERGY STAR will
review them for approval. Once approved, the Partner will be listed as an ENERGY STAR Partner.
3.	The Program Plan shall be updated annually to reflect the current practices of the program.
NOTE: Help on Program Plan development is available directly from HPwES support staff. To request assistance
contact HomePerformance@EnerqvStar.gov.
C.	Program Requirements - The Partner agrees to promote whole-house evaluation and building science-based energy
improvements to existing homes. The goal of HPwES is making cost-effective, energy-efficient improvements to
homes. The program shall consist of the following components:
1.	Home Performance Assessment or "Test-in". An energy specialist trained in building science principles will
perform a Home Performance Assessment (HPA) which will include a visual and diagnostic energy inspection of
the home using a form standardized for the program. See HPwES Sponsor Guide at
www.energystar.gov/hpwessponsors for HPA details.
2.	inspection Results and Recommended improvements, improvements to the home will be recommended
based on the initial inspection and homeowner interview. The homeowner will be given a review of the findings
and provided with a summary report including:
a.	A summary of HPA findings
b.	improvement recommendations
c.	An estimation of costs for the improvements
d.	An estimation of energy savings from implementing the recommendations.
NOTE: Recommendations for improvements will be on a fuel-neutral basis.
NOTE: See HPwES Sponsor Guide at www.energystar.gov/hpwessponsors for details.
3.	installation of measures. The program will help homeowners identify qualified contractors able to implement
the HPA recommendations. This can either be the participating contractor providing the inspection and
recommendations or other contractors qualified in home energy inspection, building science, and proper
installation techniques. All installed measures will be in accordance with industry best practices. See HPwES
Sponsor Guide at www.energystar.gov/hpwessponsors for details.
4.	Post-instaiiation Tests or "Test-out". Documentation of improvements and diagnostic testing (test-out) will be
used to verify the performance of installed measures as well as to meet health and safety standards. A summary
of the final tests will be given to the homeowner. The results may be in the form of a "Summary Certificate". See
the HPwES Sponsor Guide at www.energystar.gov/hpwessponsors for details.
D.	Program Quality Assurance (QA) Requirements -The Partner, either directly or through it's implementation
contactor, will administer a quality assurance (QA) program that meets the following minimum requirements (See
HPwES Sponsor Guide at www.energystar.gov/hpwessponsors for additional guidance on program QA):
1.	All participating contractors will agree to the terms of a participation agreement established by the Partner. The
terms of the contractor participation agreement will include a requirement to comply with the current ENERGY
STAR Identity Guidelines and properly use the HPwES logo. All jobs performed by contractors who agree to
these requirements and sign the agreement (i.e. "participating contractor") must be reported to the Partner after a
Home Performance Assessment is completed and some recommended improvements are completed.
2.	All job reports will be reviewed by the Partner based on protocols established by the Partner to identify quality of
service problems associated with jobs completed by participating contractors, if needed, the Partner may follow-
up with a contractor or conduct an on-site inspection to verify the quality of the service provided.
EPA Form 5900-17	2 of 4	2/16/2011
The government estimates the average time needed to fill out this form is 1.25 hours and welcomes suggestions for reducing this effort. Send comments (referencing OMB Control Number) to the Director, Collection Strategies
Division, J.S. EPA (2822T), 1200 Pennsylvania Ave., NW, Washington, D.C. 20460.

-------
OMB Control No. 2060-0586
3.	in addition to the above, the Partner will conduct on-site inspections, at a set inspection rate, of the work of all
participating contractors. The minimum on-site job inspection rate is set at 5% (1 in every 20 jobs).
NOTE: it is recommended that the Partner establish an adjustable on-site inspection rate for contractors based
on job experience and performance. This inspection rate reduces as the contractor gains experience in the
program and as on-site inspections show the contractor is performing well. Contactors may drop down a tier if
performance slips. Here is the recommended set of tiers:
a.	Tier 1 Contractor - The first 3-5 jobs will be inspected on-site or mentored.
b.	Tier 2 Contractor - 20% of the next 20 jobs are inspected on-site (4 out of 20).
c.	Tier 3 Contractor - 5% of all jobs inspected on-site (1 in 20).
4.	All Partners are required to have a systematic customer feedback mechanism which allows customers to provide
feedback directly to the Partner. Negative feedback must be addressed.
5.	All Partners must record and track their inspections, rate of inspections, findings, and corrective actions. Records
must be available for review when requested.
NOTE: HPwES is a voluntary program and QA communications with participating contractors should be delivered in a
positive spirit of assistance, education and continuous improvement.
NOTE: Partners may authorize an independent entity to review reports, initiate customer feedback, follow-up on
problems, perform on-site inspections, and document actions.
E. Program Data Reporting Requirements -The Partner, either directly or through it's implementation contractor,
will provide ENERGY STAR (using the address listed above) with data to assist in determining the effects of the
program and to ensure that QA is being performed by all Partners. (See HPwES Sponsor Guide at
www.energystar.gov/hpwessponsors for additional guidance on data reporting requirements.)
1.	Provide to ENERGY STAR, on a quarterly basis and in electronic format, the following minimum data:
a.	Number and names of participating contractors
b.	Number of completed jobs per contractor
c.	Number of on-site inspections completed per contractor
This information is due by April 30th for the first quarter, July 31st for the second quarter, October 31st for the
third quarter, and January 31st for the fourth quarter.
*NQTE: Partners that do not submit quarterly reports will be considered inactive and removed from the
ENERGY STAR web site. In addition, to remain active, the Partner must report a minimum of 50 jobs per
year. A new program has 2 years to meet this requirement.
2.	in addition to quarterly reporting, an annual summary report (due by December 15th for the current calendar
year) is required. This annual report will include at a minimum:
a.	An annual summary of contractor recruitment/training activities,
b.	Quality assurance activities,
c.	Marketing activities, and
d.	Future program plans.
This report should be less than three pages and can be used in a Partner's application for an ENERGY STAR
Award.
ENERGY STAR Commitments to Partners:
1.	increase awareness of HPwES by distributing key messages on the benefits of a whole-house approach to
improving energy efficiency.
2.	Provide current HPwES news, information, and reference documents (via the ENERGY STAR Web site, Hotline,
e-mail or other means).
3.	Provide ENERGY STAR Partners with public recognition for their involvement in HPwES.
4.	Respond swiftly to any Partner request for information or clarification on HPwES policies.
EPA Form 5900-17	3 of 4	2/16/2011
The government estimates the average time needed to fill out this form is 1.25 hours and welcomes suggestions for reducing this effort. Send comments (referencing OMB Control Number) to the Director, Collection Strategies
Division, J.S. EPA (2822T), 1200 Pennsylvania Ave., NW, Washington, D.C. 20460.

-------
OMB Control No. 2060-0586
General Terms and Disclaimers:
1.	The Partner will not construe, claim or imply that its participation in ENERGY STAR constitutes federal
government approval, acceptance, or endorsement of anything other than the Partner's commitment to ENERGY
STAR. Partnership does not constitute federal government endorsement of the Partner or its services.
2.	The Partner understands that the activities it undertakes in connection with ENERGY STAR are voluntary and not
intended to provide services to the federal government. As such, the Partner will not submit a claim for
compensation to any federal agency.
3.	The Partner and ENERGY STAR will assume good faith as a general principle for resolving conflict and will seek
to resolve all matters informally, so as to preserve maximum public confidence in ENERGY STAR.
4.	This agreement is voluntary and can be terminated by either party at any time for any reason. Failure to comply
with any of the terms of this partnership agreement can result in its termination. Termination of the partnership will
result in the termination and cessation of access to the benefits of ENERGY STAR, including allowance to use
any ENERGY STAR marks.
5.	ENERGY STAR will actively pursue resolution of noncompliance related to the use of the ENERGY STAR marks.
To be completed by Partnering Organization
Representative with authority to commit partnering organization to the terms of this agreement
(printed name):	
Title:	E-mail:	Phone	
Signature: 	 Date: 	
To be completed by ENERGY STAR representative:
Jonathan Passe, U.S. EPA
Signature: 	 Date:
EPA Form 5900-17	4 of 4	2/16/2011
The government estimates the average time needed to fill out this form is 1.25 hours and welcomes suggestions for reducing this effort. Send comments (referencing OMB Control Number) to the Director, Collection Strategies
Division, J.S. EPA (2822T), 1200 Pennsylvania Ave., NW, Washington, D.C. 20460.

-------
Appendix B
Program Implementation Plan Template

-------
Home Performance with ENERGY STAR
Program Plan Template
Use this Program Plan Template to develop an implementation plan. EPA and DOE are available to help answer questions and provide
guidance. Consult our HPwES Sponsor Fact sheet and Sponsor Guide for detailed guidance. Fill out and submit your Program Plan with
a signed HPwES Partnership Agreement. Please allow HPwES two weeks to review your plan. Once your plan is approved you will be
listed on our website and receive an email with My Energy Star Account (MESA) instructions to access our in-kind supporting material. We
reserve the right to decline sponsorship if we feel there is inadequate resources and planning to initiate a HPwES program, and will
Program Sponsor


Organization Type
State
Government
City or county
Government
Public Utility
Non-Profit Organization
(chartered by state to implement energy efficiency
programs}
~
~
~
~

Budget
Source of funding
System Benefit Charqe
Grant
Rate Recovery
Other
~
~
~
~
Provide background
information about the
source

Budget Category (in $)
Pilot Phase*
Yearl
Year 2
Year 3
Year 4
Year 5
Management
$
$
$
$
$
$
Proqram Development
$
$
$
$
$
$
Contractor Recruitment
$
$
$
$
$
$
Training/Certification
$
$
$
$
$
$
Mentorinq
$
$
$
$
$
$
Marketinq
$
$
$
$
$
$
Contractor Job Incentives
$
$
$
$
$
$
Homeowner Incentives
$
$
$
$
$
$
Infield Inspections (QA)
$
$
$
$
$
$
Evaluation
$
$
$
$
$
$
Total
$
$
$
$
$
$
What goals do you plan to achieve?
Contractor Participation Goal (# contractors)






Job Completion Goal (# of jobs)






Electric Savinqs Goal (kWh)






Peak Electric Savinqs Goal (kW)






Natural Gas Savinqs Goal (therms)














What metropolitan area or service territory will be served by the program?
Why did you decide to partner with ENERGY STAR to sponsor a HPwES program?

5/26/09
Page 1 of 5

-------
What current or past residential energy efficiency programs have been implemented in this market?
What is the average
electricity and natural
gas rate?
Electricity
< 8 cents/kWh
8-10 cents/kWh
>10 cents/kWh
~
~
~
Natural Gas
< 1.25 $/therm
1.2 5-1.75 $/therm
>1.75 $/therm
~
~
~
PROGRAM DELIVERY
program sponsor or i
Group A
Group B
Group C
Group D
Program Elements
Contractor Participation
Recruitment
Training
Certification
Mentoring
Group A
Implementation Partners
Group B
Group C
Group D
Consumer Financing
Consumer
Program Evaluation
is
Schedule
Activity
Year 1
Year 2
Year 3
Year 4
Year 5
Quarter
Quarter
Quarter
Quarter
Quarter
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
Identify/recruit contractors




















Train/equip contractors




















Launch marketing campaign




















Implement quality assurance
protocols




















Implement results tracking




















Explore program expansion




















Program Evaluation




















5/26/09
Page 2 of 5

-------
Which contractor delivery mode! will you
Contractor ~ Consultant ~ Hybrid ~ Other ~ (explain)
What groups, if any will be targeted / excluded? (e.g. income qualified, utility customers, city residents)
i to recruit contractors to participate in the program.
Attach a copy of the protocols contractors will follow to
t-in and test-out
t-out forms, reports or
any m
in and test
complete a comprehensive energy audit. This should include a
(e.g., blower door and combustion safety testing) as well as a
materials that are required to comply with your program's guidelines.
Attach a copy of your contractor participation agreement.
What software or other method will be used to estimate energy savings?
QUALITY ASSURANCE
Explain the steps you plan to take to ensure participating contractors deliver comprehensive energy audits and install quality
improvements,	
How will contractors report their program activity?
5/26/09
Page 3 of 5

-------
you offer an incentive for contractor reporting and if
How will completed jobs be reviewed (file and in-field)?
you help contractors represent the Home
ENERGY STAR homes, and contractors are not certified by EPA or DOE)? How will you evaluate their actions?
\ process diagram showing how contractors
sanctioned, or removed from the program.
, re-
5/26/09
Page 4 of 5

-------
MARKETING STRATEGY
What is the name of the program?
What is the proposed URL for the program web site?
increase consumer awareness of HPwES?
use, if developed.
Attach example of homeowner certificate, if
What incentives (including financing) will you offer to motivate consumers to participate?
How will you measure consumer demand for the program (e.g., number of calls, number of website visitors, duration of
website visits)?	
Please attach a copy of your plan for managing consumer inquiries about the program (e.g., workflow to handle calls and
emails).	
5/26/09
Page 5 of 5

-------