irNKRGY S1AH
PARTNER
ENERGY STAR® Program Requirements
for Commercial Ice Machines
Partner Commitments
Commitment
The following are the terms of the ENERGY STAR Partnership Agreement as it pertains to the
manufacturing of ENERGY STAR qualified commercial ice machines. The ENERGY STAR Partner must
adhere to the following program requirements:
•	comply with current ENERGY STAR Eligibility Criteria, defining the performance criteria that must be
met for use of the ENERGY STAR certification mark on commercial ice machines and specifying the
testing criteria for commercial ice machines. EPA may, at its discretion, conduct tests on products
that are referred to as ENERGY STAR qualified. These products may be obtained on the open
market, or voluntarily supplied by Partner at EPA's request;
•	comply with current ENERGY STAR Identity Guidelines, describing how the ENERGY STAR marks
and name may be used. Partner is responsible for adhering to these guidelines and for ensuring
that its authorized representatives, such as advertising agencies, dealers, and distributors, are also
in compliance;
•	qualify at least one ENERGY STAR commercial ice machine within one year of activating the
commercial ice machines' portion of the agreement. When Partner qualifies the product, it must
meet the specification (e.g., Tier 1 or 2) in effect at that time;
•	provide clear and consistent labeling of ENERGY STAR qualified commercial ice machines. The
ENERGY STAR mark must be clearly displayed on the front of the product, in product literature (i.e.,
user manuals, spec sheets, etc.), and on the manufacturer's Internet site where information about
ENERGY STAR qualified models is displayed;
•	provide to EPA, on an annual basis, an updated list of ENERGY STAR qualified commercial ice
machine models. Once the Partner submits its first list of ENERGY STAR qualified commercial ice
machines, the Partner will be listed as an ENERGY STAR Partner. Partner must provide annual
updates in order to remain on the list of participating product manufacturers;
•	provide to EPA, on an annual basis, unit shipment data or other market indicators to assist in
determining the market penetration of ENERGY STAR. Specifically, Partner must submit the total
number of ENERGY STAR qualified commercial ice machines shipped (in units by model) or an
equivalent measurement as agreed to in advance by EPA and Partner. Partner is also encouraged
to provide ENERGY STAR qualified unit shipment data segmented by meaningful product
characteristics (e.g., capacity, size, speed, or other as relevant), total unit shipments for each model
in its product line, and percent of total unit shipments that qualify as ENERGY STAR. The data for
each calendar year should be submitted to EPA, preferably in electronic format, no later than the
following March and may be provided directly from the Partner or through a third party. The data will
be used by EPA only for program evaluation purposes and will be closely controlled. If requested
under the Freedom of Information Act (FOIA), EPA will argue that the data is exempt. Any
information used will be masked by EPA so as to protect the confidentiality of the Partner;
•	notify EPA of a change in the designated responsible party or contacts for commercial ice machines
within 30 days.
ENERGY STAR Program Requirements for Commercial Ice Machines	1

-------
Performance for Special Distinction
In order to receive additional recognition and/or support from EPA for its efforts within the
Partnership, the ENERGY STAR Partner may consider the following voluntary measures and should keep
EPA informed on the progress of these efforts:
•	consider energy efficiency improvements in company facilities and pursue the ENERGY STAR mark
for buildings;
•	purchase ENERGY STAR qualified products. Revise the company purchasing or procurement
specifications to include ENERGY STAR. Provide procurement officials' contact information to EPA
for periodic updates and coordination. Circulate general ENERGY STAR qualified product
information to employees for use when purchasing products for their homes;
•	ensure the power management feature is enabled on all ENERGY STAR qualified monitors in use in
company facilities, particularly upon installation and after service is performed;
•	provide general information about the ENERGY STAR program to employees whose jobs are
relevant to the development, marketing, sales, and service of current ENERGY STAR qualified
product models;
•	feature the ENERGY STAR mark(s) on Partner Web site and in other promotional materials. If
information concerning ENERGY STAR is provided on the Partner Web site as specified by the
ENERGY STAR Web Linking Policy (this document can be found in the Partner Resources section
on the ENERGY STAR Web site at www.enenavstar.gov). EPA may provide links where appropriate
to the Partner Web site;
•	provide a simple plan to EPA outlining specific measures Partner plans to undertake beyond the
program requirements listed above. By doing so, EPA may be able to coordinate, communicate,
and/or promote Partner's activities, provide an EPA representative, or include news about the event
in the ENERGY STAR newsletter, on the ENERGY STAR Web pages, etc. The plan may be as
simple as providing a list of planned activities or planned milestones that Partner would like EPA to
be aware of. For example, activities may include: (1) increase the availability of ENERGY STAR
labeled products by converting the entire product line within two years to meet ENERGY STAR
guidelines; (2) demonstrate the economic and environmental benefits of energy efficiency through
special in-store displays twice a year; (3) provide information to users (via the Web site and user's
manual) about energy-saving features and operating characteristics of ENERGY STAR qualified
products, and (4) build awareness of the ENERGY STAR Partnership and brand identity by
collaborating with EPA on one print advertorial and one live press event;
•	provide quarterly, written updates to EPA as to the efforts undertaken by Partner to increase
availability of ENERGY STAR qualified products, and to promote awareness of ENERGY STAR and
its message.
ENERGY STAR Program Requirements for Commercial Ice Machines

-------
ENERGY STAR® Program Requirements
for Commercial Ice Machines
Eligibility Criteria
Below is the product specification for ENERGY STAR qualified commercial ice machines. A product must
meet all of the identified criteria if it is to earn the ENERGY STAR.
1) Definitions: Provided below are definitions of the relevant terms in this document1.
A.	Ice Machine: A factory-made assembly (not necessarily shipped in one package) consisting of a
condensing unit and ice-making section operating as an integrated unit, with means for making
and harvesting ice. It is an assembly that makes up to 4,000 lbs of ice per day at Standard
Ratings Conditions, as defined in Section 5.2.1 of ARI Standard 810-2006, and may also include
means for storing or dispensing ice, or both.
Ice Machine Categories
B.	Ice Making Head CIMI-D: A model with the ice-making mechanism and the condensing unit in a
single package, but with a separate ice storage bin.
C.	Remote Condensing Unit (RCU) or Split System Unit: A model in which the ice-making
mechanism and condenser or condensing unit are in separate sections.
D.	Self-Contained (SCU): A model in which the ice-making mechanism and storage compartment
are in an integral cabinet.
E.	Air-Cooled: An ice machine wherein motor driven fans or centrifugal blowers move air through the
condenser to remove heat from the refrigerant.
F.	Cubed: Cubed ice machines have an alternate freezing and harvesting period. Water is circulated
over an evaporator where it freezes until cubes are fully formed. The cubed ice is then harvested
and moved to storage. The ice may be in cube shape, or in a variation of a solid shape.
G.	Flake: Flake ice machines produce ice continuously, usually in a barrel-shaped evaporator. An
auger inside the evaporator scrapes ice off the sides into a storage bin.
H.	Nugget: Nugget ice machines use the same process as flake machines but compress the ice
flakes into nuggets.
ERGYST/
2) Qualifying Products: Commercial ice machines must meet the definitions provided in Section 1,
above, to be eligible for ENERGY STAR. Ice machines that use water-cooled technology as well
as flake and nugget ice machines are not eligible for ENERGY STAR under this Version 1.0
specification. EPA intends to include flake and nugget ice machines once a test standard is made
available and a robust database is established that may be used to derive performance requirements.
1 Definitions for ice machine, IMH, RCU, and SCU adopted from ARI Standard 810-2006, Performance Rating of
Automatic Commercial Ice Makers.
ENERGY STAR Program Requirements for Commercial Ice Machines	3

-------
3) Efficiency Requirements for Qualifying Products: Commercial ice machines must meet the
requirements provided below to qualify as ENERGY STAR.
Table 1: Efficiency Requirements for Commercial Cubed Ice Machines
Equipment Type
Harvest Rate, H
(lbs ice/day)
Energy Use Limit
(kWh/100 lbs ice)
Potable Water Use
Limit (gal/100 lbs ice)
Air-Cooled
IMH
<450
9.23 - 0.0077H
<25

>450
6.20 - 0.0010H
<25
RCU (without remote
compressor)
< 1000
8.05 - 0.0035H
<25

>1000
4.64
<25
RCU (with remote
compressor)
< 934
8.05 - 0.0035H
<25

>934
4.82
<25
SCU
< 175
16.7 - 0.0436H
<35

>175
9.11
<35
4)	Test Criteria: Partner is required to perform tests and self-certify those product models that meet the
ENERGY STAR guidelines. The test results must be reported to EPA using the Commercial Ice
Machine Qualifying Product Information (QPI) Form.
In performing these tests, Partner agrees to use the Air-Conditioning and Refrigeration Institute (ARI)
Standard 810-2006, Performance Rating of Automatic Commercial Ice-Makers.
5)	Effective Date: The date that manufacturers may begin to qualify products as ENERGY STAR will be
defined as the effective date of the agreement. The ENERGY STAR Commercial Ice Machine
Specification shall go into effect on January 1, 2008.
6)	Future Specification Revisions: ENERGY STAR reserves the right to change the specification should
technological and/or market changes affect its usefulness to consumers, industry, or the environment.
In keeping with current policy, revisions to the specification are arrived at through industry
discussions. In the event of a specification revision, please note that the ENERGY STAR
qualification is not automatically granted for the life of a product model. To qualify with the energy
and/or water efficiency criteria of ENERGY STAR, a product model must meet the ENERGY STAR
specification in effect on the date of manufacture.
Flake and Nugget Ice Machines: ENERGY STAR plans to revisit this specification once the revision
processes for ARI 810-2006 and ASHRAE 29 are complete. At that time, performance requirements
for flake and nugget ice machines will be considered and shared with industry stakeholders for review
and comment.
ENERGY STAR Program Requirements for Commercial Ice Machines

-------