~^1fC4 LNr.RGY SIAH PARTN'Ni ENERGY STAR Program Requirements for Dehumidifiers Partner Commitments Commitment The following are the terms of the ENERGY STAR Partnership Agreement as it pertains to the manufacturing of ENERGY STAR qualified dehumidifiers. The ENERGY STAR Partner must adhere to the following program requirements: comply with current ENERGY STAR Eligibility Criteria, defining the performance criteria that must be met for use of the ENERGY STAR certification mark on dehumidifiers and specifying the testing criteria for dehumidifiers. EPA may, at its discretion, conduct tests on products that are referred to as ENERGY STAR qualified. These products may be obtained on the open market, or voluntarily supplied by Partner at EPA's request; comply with current ENERGY STAR Identity Guidelines, describing how the ENERGY STAR marks and name may be used. Partner is responsible for adhering to these guidelines and for ensuring that its authorized representatives, such as advertising agencies, dealers, and distributors, are also in compliance; qualify at least one ENERGY STAR dehumidifier model within one year of activating the dehumidifiers portion of the agreement. When Partner qualifies the product, it must meet the specification (e.g., Tier 1 or 2) in effect at that time; provide clear and consistent labeling of ENERGY STAR qualified dehumidifiers. The ENERGY STAR mark must be clearly displayed on the top/front of the product, in product literature (i.e., user manuals, spec sheets, etc.), on product packaging, and on the manufacturer's Internet site where information about ENERGY STAR qualified models is displayed; provide to EPA, on an annual basis, an updated list of ENERGY STAR qualifying dehumidifier models. Once the Partner submits its first list of ENERGY STAR qualified dehumidifier models, the Partner will be listed as an ENERGY STAR Partner. Partner must provide annual updates in order to remain on the list of participating product manufacturers; provide to EPA, on an annual basis, unit shipment data or other market indicators to assist in determining the market penetration of ENERGY STAR. Specifically, Partner must submit the total number of ENERGY STAR qualified dehumidifiers shipped (in units by model) or an equivalent measurement as agreed to in advance by EPA and Partner. Partner is also encouraged to provide ENERGY STAR qualified unit shipment data segmented by meaningful product characteristics (e.g., capacity, size, speed, or other as relevant), total unit shipments for each model in its product line, and percent of total unit shipments that qualify as ENERGY STAR. The data for each calendar year should be submitted to EPA, preferably in electronic format, no later than the following March and may be provided directly from the Partner or through a third party. The data will be used by EPA only for program evaluation purposes and will be closely controlled. Any information used will be masked by EPA so as to protect the confidentiality of the Partner; notify EPA of a change in the designated responsible party or contacts for dehumidifiers within 30 days. ENERGY STAR Program Requirements for Dehumidifiers - Version 2.0 ------- Performance for Special Distinction In order to receive additional recognition and/or support from EPA for its efforts within the Partnership, the ENERGY STAR Partner may consider the following voluntary measures and should keep EPA informed on the progress of these efforts: consider energy efficiency improvements in company facilities and pursue the ENERGY STAR mark for buildings; purchase ENERGY STAR qualified products. Revise the company purchasing or procurement specifications to include ENERGY STAR. Provide procurement officials' contact information to EPA for periodic updates and coordination. Circulate general ENERGY STAR qualified product information to employees for use when purchasing products for their homes; ensure the power management feature is enabled on all ENERGY STAR qualified monitors in use in company facilities, particularly upon installation and after service is performed; provide general information about the ENERGY STAR program to employees whose jobs are relevant to the development, marketing, sales, and service of current ENERGY STAR qualified product models; feature the ENERGY STAR mark(s) on Partner Web site and in other promotional materials. If information concerning ENERGY STAR is provided on the Partner Web site as specified by the ENERGY STAR Web Linking Policy (this document can be found in the Partner Resources section on the ENERGY STAR Web site at www.enenavstar.gov). EPA may provide links where appropriate to the Partner Web site; provide a simple plan to EPA outlining specific measures Partner plans to undertake beyond the program requirements listed above. By doing so, EPA may be able to coordinate, communicate, and/or promote Partner's activities, provide an EPA representative, or include news about the event in the ENERGY STAR newsletter, on the ENERGY STAR Web pages, etc. The plan may be as simple as providing a list of planned activities or planned milestones that Partner would like EPA to be aware of. For example, activities may include: (1) increase the availability of ENERGY STAR qualified products by converting the entire product line within two years to meet ENERGY STAR guidelines; (2) demonstrate the economic and environmental benefits of energy efficiency through special in-store displays twice a year; (3) provide information to users (via the Web site and user's manual) about energy-saving features and operating characteristics of ENERGY STAR qualified products, and (4) build awareness of the ENERGY STAR Partnership and brand identity by collaborating with EPA on one print advertorial and one live press event; provide quarterly, written updates to EPA as to the efforts undertaken by Partner to increase availability of ENERGY STAR qualified products, and to promote awareness of ENERGY STAR and its message. ENERGY STAR Program Requirements for Dehumidifiers - Version 2.0 ------- ENERGY STAR ENERGY STAR Program Requirements for Dehumidifiers Eligibility Criteria Below is the Version 2.0 product specification for ENERGY STAR qualified dehumidifiers. A product must meet all of the identified criteria if it is to be qualified as ENERGY STAR by its manufacturer. 1) Definitions: Below is a brief description of a dehumidifier and other terms as relevant to ENERGY STAR. A. Dehumidifier: A dehumidifier is a self-contained, electrically operated, and mechanically refrigerated encased assembly consisting of: (a) a refrigerated surface (evaporator) that condenses moisture from the atmosphere; (b) a refrigerating system, including an electric motor; (c) an air- circulating fan; and (d) means for collecting and/or disposing of the condensate.1 B. Capacity: Capacity refers to water removal capacity at standard test conditions, measured in pints per day. Capacity will be calculated according to the test procedure provided in Section 4. C. Energy Factor: The energy efficiency of dehumidifiers will be measured in liters of water removed per kilowatt-hour (kWh) of energy consumed at standard test conditions. This metric is defined as the energy factor. Energy factor will be calculated according to the test procedure provided in Section 4. 2) Qualifying Products: Any dehumidifier that meets the definition in Section 1A, and the requirements below, is eligible to earn the ENERGY STAR. A. Standard Capacity Dehumidifiers: Dehumidifiers with daily water-removal capacities up to 75.0 US pints (35.5 Liters). B. High Capacity Dehumidifiers: Dehumidifiers with daily water-removal capacities from 75.0 US pints up to 185 US pints (87.5 Liters). 3) Energy-Efficiency Specifications for Qualifying Products: Only those products listed in Section 2 that meet the criteria outlined in Tables 1, 2 or 3 below may qualify as ENERGY STAR. Effective dates for Tiers 1, 2, and 3 are provided in Section 5 of this specification. Tier 1: Effective October 1, 2006 Table 1: Tier 1 Criteria for ENERGY STAR Qualified Dehumidifiers Product Capacity (pints/day) Energy Factor Under Test Conditions (L/kWh) Effective Date: October 1, 2006 <25 >1.20 > 25 to < 35 >1.40 > 35 to < 45 >1.50 > 45 to < 54 >1.60 > 54 to < 75 >1.60 > 75 to < 185 >2.50 i Source: Performance of Dehumidifiers, National Standard of Canada CAN/CSA-C749-94. Ontario, Canada 1994 (Reaffirmed 2000). ENERGY STAR Program Requirements for Dehumidifiers - Version 2.0 ------- Tier 2: Effective October 1, 2007 Requirements for Tier 2 of the ENERGY STAR specification for dehumidifiers are identical to those under Tier 1, except for models with a capacity of 75 pints/day. As of October 1, 2007, 75 pint models move to the next capacity bin for qualification. This means they will need to have an Energy Factor of > 2.50 L/kWh to earn the ENERGY STAR mark. Table 2: Tier 2 Criteria for ENERGY STAR Qualified Dehumidifiers Product Capacity (pints/day) Energy Factor Under Test Conditions (L/kWh) Effective Date: October 1, 2007 <25 >1.20 > 25 to < 35 >1.40 > 35 to < 45 >1.50 > 45 to < 54 >1.60 > 54 to < 75 >1.60 > 75 to < 185 >2.50 Tier 3: Effective June 1, 2008 Requirements for Tier 3 of the ENERGY STAR specification for dehumidifiers are identical to those under Tier 2, except for products in the > 54 to < 75 pints/day capacity bin. As of June 1, 2008, products with a capacity of > 54 to < 75 pints/day will need to have an Energy Factor of > 1.80 L/kWh to earn the ENERGY STAR mark. Table 3: Tier 3 Criteria for ENERGY STAR Qualified Dehumidifiers Product Capacity (pints/day) Energy Factor Under Test Conditions (L/kWh) Effective Date: June 1, 2008 <25 >1.20 > 25 to < 35 >1.40 > 35 to < 45 >1.50 > 45 to < 54 >1.60 > 54 to < 75 >1.80 > 75 to < 185 >2.50 4) Test Criteria: Manufacturers are required to perform tests and self-certify those product models that meet the ENERGY STAR guidelines. The test results must be reported to EPA using the Dehumidifier Qualifying Product Information (QPI) Form. Tests shall be conducted in accordance with Clauses 4, 5, and 7 of ANSI/AHAM Standard DH-1-2003, except that a watt-hour meter shall be used to measure dehumidifier energy consumption during the capacity rating test. The watt-hour meter shall be accurate within 0.5 percent of the indicated value and have a scale with graduations of 1 watt-hour or less. Energy Factor is to be calculated according to Section 4.2 of CAN/CSA-C749-94 (Reaffirmed 2000). 5) Effective Date: The date that manufacturers may begin to qualify products as ENERGY STAR, under the Version 2.0 specification, will be defined as the effective date of the agreement. The date that Version 2.0 goes into effect is October 1, 2006. Any previously executed agreement on the subject of ENERGY STAR qualified dehumidifier products shall be terminated effective September 30, 2006. ENERGY STAR Program Requirements for Dehumidifiers - Version 2.0 4 ------- A. Qualifying Products Under the Version 2.0 Specification: Tier 1 of the Version 2.0 specification shall commence on October 1, 2006. All products with a date of manufacture on or after October 1, 2006, must meet the new Version 2.0 requirements in order to qualify as ENERGY STAR (i.e., even products originally qualified under Version 1.0 and additional shipments of models originally qualified under Version 1.0 must meet the new requirements). The date of manufacture is specific to each unit and is the date (e.g., month and year) on which a unit is considered to be completely assembled. The second phase of this specification, Tier 2, (applicable to those products with a capacity of 75 pints/day) shall commence on October 1, 2007. The third phase of this specification, Tier 3, (applicable to those models with a capacity of > 54 to < 75 pints/day) shall commence on June 1, 2008. 6) Future Specification Revisions: EPA reserves the right to revise the specification should technological and/or market changes affect its usefulness to consumers or industry or its impact on the environment. In keeping with current policy, revisions to the specification will be discussed with stakeholders. ENERGY STAR Program Requirements for Dehumidifiers - Version 2.0 ------- |