SET THE DESIGN TARGET
When an addition is in its early design phase, Target
Finder sets a 1 -to-100 target rating for the energy
performance of the new hospital or campus (existing
campus + designed addition) based on building
characteristics. Target Finder will provide an annual
energy consumption figure for use in the design.
Select "The Target" to obtain the campus "Target
Rating" or "Energy Reduction Target" to meet the
AIA/203Q Challenge goal.
RATE THE ESTIMATED ENERGY PERFORMANCE
7. Select "View Results" to obtain your aggregate campus
"Target" energy performance rating (1-100), energy
reduction (%), source and site energy use intensity (kBtu/
sf/yr), source and site total annual energy use (kBtu),
annual energy costs, and pollution emissions figures. For
comparison purposes, the AIA/2030 Challenge goals are
also listed under "Top 10%".
Throughout the design process and when nearly finished,
enter the building characteristics and the predicted
energy consumption data (from energy modeling) into
Target Finder for the new hospital or campus (existing
campus + designed addition) to determine whether the
designed addition meets the desired target rating.
From step seven above, either click "Edit" and scroll
down the page, or begin by entering the data requested
in steps one through six above. Enter the new campus'
estimated energy use for electricity and other fuel
source(s). This should include the annual energy
consumption of the existing campus AND the anticipated
annual consumption of the addition.
9.	Enter energy costs for each fuel source
10.	Select "View Results" and compare the estimated
design energy use with the target to see if the project
achieved its goal.
11.	Print your findings by selecting "View Statement of
Design Intent".
PERFORMANCE TOOLS AND RECOGNITION
TARGET FINDER
/Is outlined above, set a
design target for the energy
performance of the future
campus (existing + new addition),
and then rate the estimated
energy performance throughout
the design phases as design
elements evolve.
PORTFOLIO MANAGER
Following one year of operation,
benchmark actual energy use of
the aggregate new campus to
determine if the facility performed
as expected, and potentially apply
for recognition.
Addition
		\	„
Existing Campus
	_>v	
Acute Care or
Children's Hospital
Garage Space/
Parking Lot
New Campus
The Designed to Earn the
ENERGY STAR logo is awarded
to designs for hospitals built
from the ground up that rate in
the top 25%. It is not available
for hospital additions.
^
DESIGNED

TO EARN THE
-V*"TflA
ENERGY STAR
ENERGY STAR
The ENERGY STAR is awarded to
hospital campuses in the top 25%
in terms of energy performance
with ratings of 75-100.
MORE INFORMATION
AIA * Architects Participating in Challenge "Green Buildings "Target Finder *2030 Challenge

-------