^£D sx
Electronic Data Deliverable (EDD)
Basic
Manual for Historic Electronic Data
EPA Region 5
Prepared By:
Region 5 Superfund Division
Environmental Protection Agency
March, 2019
Version 4.2
-------
DISCLAIMER OF ENDORSEMENT
Reference herein to any specific commercial products, process, or service by trade name,
trademark, manufacturer, or otherwise, does not necessarily constitute or imply its endorsement,
recommendation, or favoring by the United States Government. The views and opinions of
authors expressed herein do not necessarily state or reflect those of the United States
Government, and shall not be used for advertising or product endorsement purposes.
-------
TABLE OF CONTENTS
1.0 INTRODUCTION 1
2.0 GENERAL EDD REPORTING REQUIREMENTS 2
2.1 File Formats 2
2.2 EDD Files 3
2.3 File Naming Convention 5
2.4 Data Integrity Rules 7
2.5 Reporting Null Values 7
2.6 Valid Values 9
2.7 Reporting Non-Detects 10
2.8 Reporting Re-Tests 11
2.9 Reporting Tentatively Identified Compounds 11
2.10 Using the Electronic Data Processor to Check EDD Formatting 12
2.11 Submitting Your EDD to EPA Region 5 12
3.0 EDD FILE FORMATS for Historical data 14
3.1. Data Provider (EPAR5Data Provider_v3) 14
3.2 SUBFACILITY EDD File 16
3.3 Basic Location EDD File 18
3.4 Basic Chemistry Sample Result EDD File 20
3.5 Basic Water Level EDD File 26
3.6 Basic Geology EDD File - Optional 28
-------
1.0 INTRODUCTION
The Basic Manual for Electronic Data describes the requirements for electronically submitting
"historical" operation and maintenance (O&M) data to EPA Region 5. O&M data is considered
to be "historical" if it was collected between the time remedy construction was completed up to
and including the most recent data collection event. The data provider should anticipate all
future data being collected for a site to be submitted on a regular basis (at least annually or semi-
annually) in accordance with this manual. The data provider is also encouraged to become
familiar with and submit EDDs in accordance with the standard EPA Region 5 Comprehensive
Specification Manual for Electronic Data. EPA Region 5 anticipates requiring all data providers
to submit EDDs in accordance with the standard EPA Region 5 Comprehensive Specification
Manual for Electronic Data.
The intent of developing special requirements for historical information is to decrease the burden
associated with reporting in-depth details about data that may have been collected a number of
years ago. EPA recognizes that some information about data collected in the past may not be
readily available and, by reducing the requirements for electronic historical data, is endeavoring
to strike a balance between minimizing the amount of effort involved in inputting information
and maximizing the ability to document remedy progress.
This information is also available on the Region 5 Superfund EDD Website located at:
https://www.epa.gov/superfund/region-5-superfund-electronic-data-submission
Basic Manual for Historic Electronic Data
Version4.2
l
US EPA Region 5
March, 2019
-------
2.0 GENERAL EDD REPORTING REQUIREMENTS
2.1 File Formats
All EDD data from EPA Region 5 data providers must be reported as text files. EDD files can be
produced using any software with the capability to create text files. These files are especially
easy to create using spreadsheet or database software packages. However, if these are
unavailable, the files can be created using a word processor or text editor. Table 2-1 provides
instructions for creating tab-delimited text files from some widely-used software packages.
Table 2-1 Instructions for Producing Tab-Delimited Text Files
Package
Type
Instructions
Access
Database
Create tables using file structures in Section 3.
After data are entered, close table.
Click on table name (under table tab) and then select
"File," "Save As," from the top menu. Save to an
external file or database. Change "Save as Type" to a text
file. Change the file extension from "txt" to "tab." Press
OK. This will start the export wizard.
In the export wizard, select "Delimited," then press the
"Next" button. Select "Tab" as the delimiter type and "
as the text qualifier. Press the "Next" button. Select a
destination and name for the file. Press the "Finish"
button.
Excel
Spreadsheet
Select "File," "Save As," from the top menu. Change
"Save as Type" to a "Text (Tab Delimited)" file. Press
the "Save" button.
Quattro® v8
Spreadsheet
Select "File," "Save As," from the top menu. Change the
"File Type" to "ASCII Text (Tab Delimited)." Press the
"Save Button."
Word
Word
Processor
[Note: A word processor is not the best tool for the job!
A large paper size will have to be selected to prevent
wrapping for most files. ] [wrapping?]
Enter data into a table in Word. Any text entered must be
contained within double quotes.
Select "Table," "Select Table," from the top menu.
When the table is highlighted, select "Table," "Convert
to Text," "Separate Text with Tabs."
Select "File," "Save As," from the top menu. Change
"Save as Type" to "MS DOS Text (*.txt).
Lotus 1-2-3
Spreadsheet
Select "File," "Save As," from the top menu. Change
"Save as Type" to a "Comma Separated Value (CSV)"
file. Provide file name. Press the "Save" button.
Basic Manual for Historic Electronic Data
Version4.2
2
US EPA Region 5
March, 2019
-------
A Microsoft Excel Workbook file, EPAR5BasicEDD.xls, provides electronic templates for EDD
files. To create an EDD, simply enter your data into the worksheets provided and then follow the
instructions in Table 2-1 to create a tab-delimited text file.
A Microsoft Access database file, EPAR5BasicEDD.mdb, also provides electronic templates for
EDD files. To create an EDD, simply enter your data into the database files provided and then
follow the instructions in Table 2-1 to create a tab-delimited text file.
2.2 EDD Files
The tables in this guidance identify the various types of data being requested. Each EDD file
should be saved as an individual text file and should be named in accordance with the naming
convention rules. Table 2-2 provides general information on the files that make up this EDD.
Detailed instructions for creating all the EDD files are provided in Section 3. Instructions for
submitting your EDDs to EPA Region 5 are presented in Section 2.11
Table 2.2 General Information on EDD Files
What makes a
Dependence of
File Type
File Name
Created
Contents
row of data
other files on
By
unique?
these data
FILES_v3
SiteName.dxf,
drawing (.dwg) or
ArcGIS
shapefiles.
Document or
cover letter in
PDF, or doc
format.
Data
provider
Basemap or cover
letters about the
EDD.
Not applicable
Not applicable.
Data
Date.
Data
Information about
Data Provider co
Not applicable
Provider
EPAID.
Provider
the data provider
de
(Section
3.1)
Epar5DataProvi
der_v3.txt (or
csv)
Site
Date.
Data
One-time definition
Site code
The location file
(Section 3.2)
EPAID.
EPAR5 SUBFACI
LITY_v3.
Txt (or csv)
provider
of site including EPA
Region 5 data
providers' contact
information.
cannot be loaded
without properly
referenced sites
(sitecode).
Basic Manual for Historic Electronic Data
Version4.2
3
US EPA Region 5
March, 2019
-------
Table 2.2 General Information on EDD Files
File Type
File Name
Created
By
Contents
What makes a
row of data
unique?
Dependence of
other files on
these data
Basic
Location
(Section 3.3)
Date.EPAIDCode.
EPAR5_BasicLO
C_v3.txt (or .csv).
Data
provider'
s
surveyor
One entry for each
location on a site.
Contains elevation,
coordinate and
general locational
data. Data should
only be reported once
for a location.
Sysloccode
Sample Results,
water levels, field
measurements,
geology and
extraction well
data can only be
reported for
locations that are
defined in this
file.
Basic
Chemistry
Sample
Result
(Section 3.4)
Date.
EPAID.
EPAR5_BasicChe
m_v3.
Txt (or csv)
Data
provider'
s field
sampling
team(s)
and
testing
lab(s)
One row for each
analyte reported for a
given sample and
test. Additional rows
can be added to
report total and
dissolved results and
to report results for
re-extracts.
Syssamplecode
lab_anl_method_
name
analysisdate
totalordissolved
testtype
casrn
None
Basic Water
Level
(Section 3.5)
Date.EPAIDCode.
EPAR5_BasicWT
R_v3.txt (or .csv).
Data
provider'
s field
sampling
team(s)
Groundwater level
data for monitoring
wells
sysloccode
measurementdate
measurementtime
None.
Basic
Geology
(Optional)
(Section 3.6)
Date.EPAIDCode.
EPAR5_BasicGE
0_v3.txt (or .csv).
Data
provider'
s
geologist
Geology data for a
borehole.
Sysloccode
startdepth
None.
Basic Manual for Historic Electronic Data
Version4.2
4
US EPA Region 5
March, 2019
-------
2.3 File Naming Convention
-Sign and Submit
After using the tools outlined above to resolve all of the issues in a set of Data Files the data is ready to be
submitted for loading into the EQuIS 6.5.1 database. The Sign and Submit tool was designed to facilitate
submittal of data to EQuIS Enterprise EDP. Sign and Submit option packages the data files with the
correct naming convention which allows easy submittal of data packages. Use of the Sign and Submit
feature requires a user name and password which can be obtained from the EPA Region 5 database
administrator. Please email to canar.iohn@epa.gov for the information.
To use the "Sign and Submit" feature, after data files have been loaded and all of the errors have been
resolved,
1. Select Sign and Submit from the Application Menu. This will open the Sign and Submit window.
Sign and Submit
User Name:
Password:
Facility ID
KH
_ Save Password
Save
Figure 13: Sign and Submit Window
2. Enter your User Name and Password, and select the facility ID from the drop down that applies to the
data package being submitted. If the Facility ID does not exist, users can send a request to Region 5
contact to add it to the list.
3. Click the Save button, and verify if the facility you selected is corrected:
Basic Manual for Historic Electronic Data
Version4.2
5
US EPA Region 5
March, 2019
-------
Sign and Submit
£3
EPAR5 Sign And Submit
Are you sure this is the correct facility?
Yes
No
Figure 14: verify the facility
4. Click "Yes". Users will be prompted to provide a filename and location where you would like to save
the file. The Sign and Submit feature will save an archived ("zipped") the current date, a period, the
EPA ID, a period and the Format File name used to create the EDDs. (Example file name: '20160811.
MID000000001.EPAR5.zip"). The contents of the Zipped file include text files named for the sections of
the format used to create them.
5. Select Save. Once die zipped EDD Package has been saved the following screen will appear.
erName: username
EQuIS Professional
35
IC
EDD Signed and Saved
£
OK
-
Figure 15: saved the EDD file
6. Select OK
After the zipped file has been created the EDD Package is ready to be submitted to your regulator for
loading into EQuIS Professional EDP or EQuIS Enterprise EDP.
-Each EDD file naming convention
Each file, except the base map file, must be named according to the following convention:
Date.EPAID.EDDFileFormat_v3.txt (or .csv)
The first part of the file name is the site name, followed by the submittal date of the EDD with the format for
the date being YYYYMMDD The second part of the file name is the EPA ID number. The third part of the
Basic Manual for Historic Electronic Data
Version4.2
6
USEPA Region 5
March, 2019
-------
file name refers to the EDD file format for the file being submitted. The "_v3" suffix is an EPA marker to
identify which version of the EDD specifications is being followed, and should not
be changed by the data provider. The name of the site base map file should include the site name and EPAID
and be saved in .dxf format.
As an example, sample and result data for the ABC site (EPA identification number of
XYZ123456789) that is being submitted to EPA on January, 1st, 2016 would be reported in a file
named 20160101.XYZ123456789.BasicChemistry_v3.txt (or .csv).
2.4 Data Integrity Rules
Data providers are responsible for running three types of integrity checks on their data.
Validity . All codes used in a data set must be valid. Valid values for all coded fields are either
provided in the description columns of the tables in Section 3 or in the tables in the Valid Value
Appendix of this manual. For example, sample matrix information is inputted in the
samplematrixcode field of the Sample Result file and must be reported using one of the values
provided in Table A-l in the Valid Value Appendix.
Row Uniqueness. Row uniqueness must be verified using the guidance provided in Table 2-2.
Row uniqueness is assured when no two rows in a file contain the same values for all the fields
listed under the heading "What makes a row of data unique?". In database terminology this is
called a primary key. For example, the sys loc code is the primary key in the Location EDD file
and therefore no two rows in the can have the same sys loc code.
Row Integrity . The relationship between rows within the files of the EDD must be assured by
enforcing the "referential integrity" rules discussed in Table 2-2 under the column labeled
"Dependence of other files on these data." For example, the values in the sys loc code field in
the Sample Result file must match with a value previously reported in the sys loc code field of
the Location file.
2.5 Reporting Null Values
When a field is not listed as required in Section 3 and the data is not available or applicable, a
null or blank may be appropriate. However, tabs or commas must still delimit the blank value. In
other words, the number of fields is always the same, whether or not the fields include data. So a
blank field in a tab-delimited file would appear as "" and a blank field in a
comma-delimited file would appear as Table 2-3 shows a number of examples.
Table 2-3. Examples of how to report null values
Example
Comment
"data_one""data_two"
"data_three"
" data_one"," data_two",'" data_three"
O.K. All fields populated, one tab or comma
between fields.
Basic Manual for Historic Electronic Data
Version4.2
7
US EPA Region 5
March, 2019
-------
Table 2-3. Examples of how to report null values
Example
Comment
"dataone" "data_three"
" data_one" „" data_three"
O.K. Optional field not populated, 2 tabs or 2
commas between first and third field.
"data one" "data_three"
" data_one"data_three"
Not O.K. Optional field omitted, only 1 tab or
comma between first and third field.
Basic Manual for Historic Electronic Data
Version4.2
8
US EPA Region 5
March, 2019
-------
2.6 Valid Values
Valid values, also known as reference values or code lists, govern the contents of some fields in
the EDD files. In other words, some fields may only be populated with data that matches a value
listed in the EPA Region 5 list of valid values in Valid Value Appendix of this Manual. A list of
all the data fields that must contain valid values is presented in Table 2-4. This list is also cross-
referenced to the EDD file(s) the field appears in. If data providers need to enter a value not
already in the Region 5 list in Valid Value Appendix, they can request the proposed addition to
the valid value list in the EDD submittal cover letter. The data provider should explicitly state the
valid value that she/he would like added, provide a description of the value, and explain why the
addition is necessary. In the case of requesting a new laboratory code, the data provider should
include the full name of the laboratory and its address. When requesting an addition of an
analyte, the data provider must include the appropriate CAS number or ERPMS code along with
a description of the analyte.
Basic Manual for Historic Electronic Data
Version4.2
9
US EPA Region 5
March, 2019
-------
Table 2-4. Cross-reference between the valid value tables in appendix and the EDD files
Valid Value Table
Name
Table
Number
Field Name
EDD File
Matrix
A-l
samplematrixcode, labmatrixcode
Chemistry
Sample Result
Location Type
A-9
locjype
Location
Qualifier
A-10
labqualifiers, validator qualifiers
Chemistry
Sample Result
Result Type
A-l 1
resulttypecode
Chemistry
Sample Result
Sample Type
A-12
sampletypecode
Chemistry
Sample Result
Analyte
A-l 5
cas rn, chemicalname, dnaplcasrn,
lnaplcasrn
Chemistry
Sample Result
Water Level
Lab Analysis Method
Name
A-16
labanlmethodname
Chemistry
Sample Result
Unit
A-l 8
various unit fields throughout all files
All Files
Geology Soil
Materials
A-19
materialtype
Geology
EPA Facility IDs
A-22
facility id, site_name, city
Site
Company Codes
A-23
Data_provider_code, data_provider
Location, Sample,
Test Result, Data
Provider
TotalorDissolved
A-24
T otalordi s sol ved
Test Result, Test
Result QC, Batch
Test Type
A-25
Test_type
Test Result, Test
Result QC, Batch
Test Batch Type
A-26
Testbatchtype
Batch
2.7 Reporting Non-Detects
Non-detects must be reported as shown in the example below. Each non-detect row must show
an "N" in the detect flag field and must have values entered in the reportingdetectionlimit
and detectionlimitunit fields (i.e., these fields cannot be left null if record is a non-detect).
Table 2.5 presents an examples how to report a detect (1st row) and non-detect (2nd row) data.
Table 2-5. Example of reporting non-detects
Cas rn
Result
Detect
Reporting
Detection
Result comment
Laboratory
Value
Flag
Detection
Limit Unit
qualifiers
Basic Manual for Historic Electronic Data
Version4.2
10
US EPA Region 5
March, 2019
-------
Limit
108-88-3
.15
Y
.005
ug/ml
U
108-88-3
N
.005
ug/ml
not detected
U
2.8 Reporting Re-Tests
For initial tests, all analytes should be reported. In the case where retests are performed on a
sample, the result that is considered the reportable result should indicate a "Y" (for "yes") in the
reportableresult field. The initial test, and any retest result not considered reportable will have
reportableresult set to "No". Table 2.6 provides examples of reporting re-tests.
Table 2-6. Example of reporting re-tests
Test
Type
Chem
Name
Cas rn
Result
Value
Detect
Flag
Lab
Qualifiers
Reportable
Result
ResultComment
Initial
Benzene
71-43-2
1000
Y
E
No
too concentrated
to quantitate
Initial
Toluene
108-88-3
5
N
U
Yes
not detected
Initial
Xylenes
1330-20-
7
5
N
U
Yes
not detected
Dilution
1
Benzene
71-43-2
780
Y
Yes
quantitated
2.9 Reporting Tentatively Identified Compounds
Tentatively Identified Compounds (TICs) should be reported when available. The naming of
TICs should be applied in a cascade fashion. The TIC should be identified to analyte name if
possible. If this is not possible, then the class of the TIC should be entered.. If neither an analyte
name or a class can be identified, the TIC should be identified as Unknown. The EPA Region 5
EDD only allows for reporting up to 10 TICs. Only the 10 most concentrated or most relevant
TICs should be reported. Table 2-7 shows examples of the nomenclature for TICs. As an
example, if a sample has three Unknown Hydrocarbons, then the TICs are labeled
UnkHydrocarbl, UnkHydrocarb2, and UnkHydrocarb3. TIC names are to be reported in the
casrn field, Pos #23, of the Chemistry Sample Result file (Section 3.4). In addition, the
result type code, Pos # 26 in the Chemistry Sample Result file should have "TIC" for all TIC
records.
Table 2-7. Example nomenclature for TIC reporting
TIC Name
Number for TIC
Reported Name in cas rn
Unknown
1-10
Unknown 1 - Unknown 10
Unknown Hydrocarbon
1-10
UnkHydrocarbl - UnkHydrocarbl0
Unknown PAHs
1-10
UnkPAHl - UnkPAHIO
Basic Manual for Historic Electronic Data
Version4.2
li
US EPA Region 5
March, 2019
-------
Unknown Aromatics
1-10
UnkAromaticl - UnkAromaticlO
Unknown VOA
1-10
UnkVOAl - UnkVOAlO
Unknown SV
1-10
UnkSVl - UnkSVIO
2.10 Using the Electronic Data Processor to Check EDD Formatting
All EDD files must be ran through the Electronic Data Processor (EDP) prior to submittal to
EPA Region 5. The EDP is used by Data Providers to check EDD files prior to submittal to EPA
Region 5. The EDP is a no-cost application that performs a series of formatting checks on the
files and then identifies any records that have errors along with a description of those errors.
This allows the Data Provider to correct the errors before sending the files to EPA Region 5.
EDD files that pass through the EDP error-free should also result in error-free import at EPA
Region 5.
EDP is currently available as a no-cost download from the EPA Region 5 E-Data website located
at https://www.epa.gov/superfund/region-5-superfund-electronic-data-submission
Instructions on how to install and use the EDP are also provided on the website.
2.11 Submitting Your EDD to EPA Region 5
Each EDD must be checked using the EDP and the most updated EDD format before submitting to
EPA Region 5. Please follow the three steps below to submit your EDD data:
Email to get the username, password:
-Send email to canar.iohn@epa.gov to get the username, and password. Data providers are
required to get the username, and password to use the Sign and Submit process to create a EDD zip
package after the data has been checked with the EDP with no errors. The Sign and Submit process
allows data provider to save the EDD in their preferred folder or directory. The EDD zip package
should be named using the naming convention that was shown in section 2.4.
Email to EPA Region 5 EQuIS Enterprise Database:
- Once the EDD zip file has been created, the EDD is ready to be emailed to EPA EQuIS Enterprise
processor. Please follow the following 2 steps:
1. Change the file extention from ".zip" to ".edd". In other words, your EDD is zipped in EDP, such as
"20160811. MID000000001.EPAR5.zip", you need to change the file extention to ".edd", meaning the file
name will become "20160811. MID000000001.EPAR5.edd"
2. Send the ".edd" file to to EPAR5@EQuISOnline .com
Notify EPA Region 5 when the data is sent to the EPA Region 5 EQuIS Enterprise database:
Please notify the EDD database administrator canar.iohn@epa.gov for each EDD that has
been emailed to the EPA Region 5 EQuIS Enterprise database.
Basic Manual for Historic Electronic Data
Version4.2
12
US EPA Region 5
March, 2019
-------
EDD submittal types
There are three possible EDD submittal types: an original submittal, an error correction resubmittal,
and an update submittal. These three EDD types are described below.
¦ Original Submittal: An original EDD submittal contains data being submitted for the first
time to EPA Region 5. EPA Region 5 will process and check the EDD. If there are no errors
in any of the EDD files, EPA will import the data to the permanent database. EPA Region 5
can only import and accept the EDD submittal if all files in the submittal are error-free. If
any of the files on the EDD contain errors, EPA will send the data provider a letter
specifying the errors that need to be corrected.
¦ Correction Resubmittal: In the case where an original EDD submittal contains errors, the
entire EDD submittal will be returned to the data provider along with an error report
explaining the problems identified. The data provider should then correct the errors, check
the files again with the EDP, and then resubmit the entire EDD. A response is required
within 30 days. It is important that the resubmitted EDD contain all of the files and the
SAME FILE NAMES (i.e., use the same site name and submittal date in the file name as
was used in the original submittal) as those in the original submittal. Thus, the EDD
resubmittal will be identical to the original submittal in everyway except the errors are
corrected.
Update Submittal: This type of submittal updates data that has previously been accepted by
EPA Region 5. The files of an update submittal should follow the normal naming convention of
an EDD submittal and contain only data for the records being updated. For example, say a data
provider submits an EDD in 2014 that includes a location file (e.g.,
20014121.EPAID.EPAR5LOC_v3.txt) that contains ten locations, and the EDD is accepted by
EPA Region 5 and loaded into the EPA database. If, in 2016, the site is resurveyed, and it is
discovered that three of the locations' coordinate information has changed due to increased
accuracy, a new location file containing data for only those three locations would need to be
submitted as an update submittal. The update submittal would be named using the current
submittal date of the update (e.g., 20160108.EPAID.EPAR5LOC_v3.txt). Note: All required
fields need to be populated for the three locations regardless of whether or not these fields were
updated. The reason for the update submittal and the records that have been changed must be
clearly indicated in the cover letter accompanying the updated EDD.
Basic Manual for Historic Electronic Data
Version4.2
13
US EPA Region 5
March, 2019
-------
3.0 EDD FILE FORMATS for Historical data
This section contains detailed information regarding the files that make up the Region 5 EDD Files for Historical Data. As stated in
section 2.1, each file must be saved as individual text files and can be created using any software with the capability to create text files.
If a column is limited to a specific number of characters, the limit will be given in parenthesis within the "Data Type" column (e.g.,
Text (3) signifies the value cannot exceed 3 characters in length). Columns marked "Required" must be reported for each row in the
file. If these fields are not reported, errors will be identified in the EDD and the EDD will need to be resubmitted. Columns marked
"If available" should also be reported if possible, and columns marked "Not required" meaning the field is not a required field.
There are three EDD files in the EDD format should be submitted as part of the first EDD submittal, they are Data Provider
(EPAR5DataProvider_v3), Subfacility (EPAR5SUBFACILITY_v3) and Basic Location (EPAR5_BasicLOC_v3) files. These 3 files
only need to be submitted once unless information in the files change or additional information, such a new sampling location, needs
to be added.
Examples of populated EDD files are provided in Attachment 1.
3.1. Data Provider (EPAR5Data Provider_v3)
The Data Provider EDD file provides general information about the data provider who is the contact for the data on the site.
Date.EPAIDCode.EPAR5DATAPROVIDER_v3.txt (or .csv)
Basic Manual for Electronic Data
Version 4.2
14
USEPA Region 5
March, 2019
-------
Table 3.1 Data Provider (EPAR5DATAPROVIDER_v3) File Structure
Pos#
Column Name
Data Type
Required
Description
Valid Values
In Appendix
1
DataProvider
Text(20)
Required
This is the name of the company who is responsible for providing the
site data.
A-23
2
DataContact
Person
Text(30)
Not Required
This is the name of the contact person who is responsible for
providing the site data.
No
3
DataContact
Address 1
Text (40)
Not required
Data Provider address 1
No
4
DataContact
Address2
Text (40)
Not required
Data Provider address 2
No
5
DataContact
City
Text (30)
Not required
Data Provider city
No
6
DataContact
State
Text(5)
If Available
Contact state
No
7
DataContactzi
pcode
Text(10)
Not required
Contact zip
No
8
DataContact
email
Text(60)
Required
Contact email address
No
9
DataContact
Phone
Text(30)
Not Required
Contact phone number
No
Basic Manual for Electronic Data
Version 4.2
15
USEPA Region 5
March, 2019
-------
3.2 SUBFACILITY EDD File
The Subfacility EDD file is typically a one-time-only submittal and must be submitted as part of the first EDD submittal. This file
contains general information about the site, along with information such as the name, address, and phone number of the main contact
responsible for data submittal. If the Site EDD file has already been submitted for the site, and none of the information in the file has
changed, you do not have to resubmit the file. The only time this file is resubmitted is when information about the contact person or
other information in the file changes.
For historical data, the SUBFACILITY EDD file, and all the requirements related to it, are exactly the same as are described for the
SUBFACILITY EDD file in the EPA Region 5 Comprehensive EDD Specification Manual for non-historical data.
SUBFACILITY EDD files should be named according to the following convention:
Date.EPAIDCode.EPAR5SUBFACILITY_v3.txt (or .csv).
Basic Manual for Electronic Data
Version 4.2
16
USEPA Region 5
March, 2019
-------
Table 3-2 SUBFACILITY (EPAR5SUBFACILITY v3) data file structure
Pos#
Column Name
Data Type
Required
Description
Valid Values
In Appendix
1
SUBFACILITYcode
Text(3)
Required
Code indicating the site operable unit for which the data is collected,
or area of concern (AOC). Typically the code is "01" unless there is
a second or third operable unit at facility. Codes of "02" and "03"
should be used for second and third operable units, respectively.
Contact the EPA RPM if unsure of proper code.
No
2
subfacilityname
Text(60)
Required
Name of site
Table A-22
3
subfacilitytaskcode
Text(40)
Required
Code used to identify the task under which the site or area is
investigated. This field is for informational purposes only. Field
samples are formally associated with task codes.
No
4
subfacilitydescl
Text(255)
If available
General description of the site.
No
5
subfacility_desc2
Text(255)
If available
Additional description of site, if necessary.
No
6
contactname
Text(50)
Required
Name of person to contact if EPA Region 5 has any questions about
the EDD.
No
7
addressl
Text(40)
Required
Site address, part one.
No
8
address2
Text(40)
Not required
Site address, part two. Default to null if information is not needed
No
9
City
Text(30)
Required
Site city.
No
10
State
Text(2)
Required
Site state.
No
11
Zipcode
Text(10)
Required
Site zip code.
No
12
phonenumber
Text(30)
Required
Site contact phone number.
No
13
alt_phone_number
Text(30)
If available
Alternate phone number for site contact. Default to null where the
data are not available.
No
14
faxnumber
Text(30)
If available
Fax number of site contact. Default to null where the data is not
available.
No
15
emailaddress
Text(lOO)
Required
Site contact e-mail address.
No
Basic Manual for Electronic Data
Version 4.2
17
USEPA Region 5
March, 2019
-------
3.3 Basic Location EDD File
The Location file is another EDD file that is typically submitted only once and must be part of the first EDD submittal. The location
file only needs to be resubmitted if a new sampling location is used, such as a new monitoring well, or to update previously submitted
information. When resubmitting the location file, only include data for the new locations and/or for the locations whose information is
being updated. The Location EDD file contains general information about sampling locations and sample ID numbers. This table does
not need to be resubmitted if information has previously been submitted to EPA Region 5 in the EDD format
Location files should be named according to the following convention:
Date.EPAIDCode.EPAR5_BasicLoc_v3.txt (or .csv).
Table 3.3 Location Data(EPAR5_BasicLOC_v3) File Structure
Pos#
Column Name
Data Type
Required
Description
Valid Values
In Appendix
1
Data Provider
Text(20)
Required
Data provider company code.
A-23
2
Facilitycode
Text (20)
Required
EPA ID code- Facility Identifier code
A-22
3
Sysloccode
Text (20)
Required
Location identifier of sample collection, soil boring, or well
installation. Example of possible sys loc code are MW-01,
SB6...etc.
No
4
Alternatewellid
Text (20)
Not
Required
Well ID
No
5
Primarysubfacilitycode
Text (20)
Required
Unique code for Operable Unit (subfacility/ area).
No
6
Xcoord
Number
w/precision
of up to 15
Required
Sampling location numeric X UTM NAD83 coordinate in
meters
No
7
Ycoord
Number
w/precision
of up to 15
Required
Sampling location numeric Y UTM NAD83 coordinate in
meters
No
Basic Manual for Electronic Data
Version 4.2
18
USEPA Region 5
March, 2019
-------
Table 3.3 Location Data(EPAR5_BasicLOC_v3) File Structure
Pos#
Column Name
Data Type
Required
Description
Valid Values
In Appendix
8
surfelev
Number
w/precision
of up to 15
Required
Elevation in feet above sea level of the ground surface at the
sampling location.
No
9
Coordtypecode
Text (20)
Required
Sampling location coordinate system description. Must be
"UTM Zone nn".
No
10
locname
Text(40)
Not
required
Sampling location name. (May be identical to entry in column
1.)
No
11
locdesc
Text(255)
Not
required
Description of sampling location.
No
12
loctype
Text (10)
If available
Description of sampling type, such as direct push, extraction
well, or sediment. Use "CENTROID" to identify facility center
point. Use codes from Table A-9 in the Appendix.
Table A-9
13
locpurpose
Text (20)
Not
required
Brief description of purpose for collecting sample.
No
14
within_facility_yn
Text (1)
Required
Indicate whether this sampling location is within the facility
(site) boundary.
Y= Yes N= No
15
depthtotopofscreen
Number
w/precision
of up to 15
Not
required
Depth to the top of the well screen in feet below ground surface.
Default to null if sample is not from a well.
16
depthtobottomofscreen
Number
w/precision
of up to 15
Not
required
Depth to bottom of well screen in feet below ground surface.
Default to null if sample is not from a well.
No
17
topcasingelev
Number
w/precision
of up to 15
Not
required
Elevation of top of well casing in feet. Default to null if sample
is not from a well.
No
Basic Manual for Electronic Data
Version 4.2
19
USEPA Region 5
March, 2019
-------
Table 3.3 Location Data(EPAR5_BasicLOC_v3) File Structure
Pos#
Column Name
Data Type
Required
Description
Valid Values
In Appendix
18
depthtobottomofwell
Number
w/precision
of up to 15
Not
required
Depth to bottom of well in feet below ground surface. Default to
null if sample is not a well.
No
19
totaldepth
Number
w/precision
of up to 15
Not
required
Total depth of boring below ground surface in feet. Default to
null if sample is not a well.
No
20
remarks
Text (255)
Not
required
Any comments or information regarding the information in this
EDD file.
3.4 Basic Chemistry Sample Result EDD File
The Basic Chemistry Sample Result EDD file contains sample, test and result data. Data from both laboratory analysis and in situ
measurements taken in the field - such as pH, conductivity, and dissolved oxygen - are to be reported in this file. For surface water
samples, record the sample depths, start depth (field 9) and end depth (field 10), as depth below the water surface elevation. The
water surface elevation at the time of the sampling should be recorded in the Water Level file (see Section 3.5).
Each Basic Chemistry Sample Result EDD file should be named according to the following convention:
Date.EPAIDCode.EPAR5_BasicCHEM_v3.txt (or .csv)
Table 3-4. Basic Chemistry sample (EPAR5_BasicCHEM_v3) file data structure
Basic Manual for Electronic Data
Version 4.2
20
USEPA Region 5
March, 2019
-------
Pos#
Column Name
Data Type
Required
Description
Valid Values
In Appendix
1
Data_provider
Text (20)
Required
Data provider company code
A-23
2
syssamplecode
Text(40)
Required
Unique sample identifier. Each sample must have a unique value to
identify the sample, including spikes and duplicates. If no sample ID is
available, enter the sys loc code plus the sample date. (e.g., MW01 +
March 11, 1991=> MW01031191). For trip blanks that do not have
unique sample IDs, enter «TB. plus the date, e.g., TB + April 5, 2000
=> TB04052000.
No
3
sysloccode
Text (20)
Not required
Sample collection location. Enter the same sys loc code, such as MW-
01, A24, SW12, or SB-2S, as it appeared in the Location EDD file.
*Field should be null if sample is not associated with a location, such
as a field QC sample (e.g., field blank or trip blank).
No
4
samplename
Text (50)
Not required
Additional sample identification information, if necessary. Should be
the same value as in the sys sample code field if no further naming
information applies.
No
5
sample matrix code
Text (3)
Required
Code which distinguishes between different types of sample matrix
Table A-l
6
sampletypecode
Text (3)
Required
Code which distinguishes between different types of samples, for
example field samples versus laboratory method blank samples
Table A-12
7
samplesource
Text (10)
Required
This field indicates if the sample originated in the field or in the lab.
For the BasicCHEM EDD file, in almost all cases the correct entry will
be aFicld.*
FIELD OR
LAB
8
parentsamplecode
Text (40)
Note
Required
This field applies to duplicate samples only and should contain the
entry in the "sys sample code" field for the sample from which the
duplicate sample was derived, i.e., the ¦parent, sample. If the sample is
not a duplicate sample, the field should be left null. A value other than
¦null* is required whenever the entry in the ¦sampletypecode*
column is FD, FR, FS, or LR.
No
Basic Manual for Electronic Data
Version 4.2
21
USEPA Region 5
March, 2019
-------
Table 3-4. Basic Chemistry sample (EPAR5_BasicCHEM_v3) file data structure
Pos#
Column Name
Data Type
Required
Description
Valid Values
In Appendix
9
sampledate
Datetime
Required
Date sample was collected in MM/DD/YYYY format. If exact date is
not known, enter the best estimate for the date of sampling. If an
estimated date is entered, note this and provide an explanation for how
the estimate was made in both the EDD cover letter and in the
comment field in this file (field 36).
MM/DD/YYYY
format
10
startdepth
Number
w/precision
of up to 15
Not Required
Beginning depth (top) of sample in feet below ground surface for Soil
or Groundwater sample. Only use for groundwater samples if discrete
samples are taken at different depth elevations from a single well, i.e.
multiple well packer samples.
No
11
enddepth
Number
w/precision
of up to 15
Not Required
Ending depth (bottom) of sample in feet below ground surface for Soil
or Groundwater sample. Only use for groundwater samples if discrete
samples are taken at different depth elevations from a single well, i.e.
multiple well packer samples.
No
12
depthunit
Text (15)
if available
Unit of measurement for the sample beginning and ending depths
Default to null if not applicable.
Table A-18
13
composite_yn
Text (1)
Not required
Code used to indicate whether a sample is a composite sample. Enter
¦Y. for yes and «N. for no. Default to null if the data are not available.
Y=yes
N=no
14
labanlmethodna
me
Text (35)
Required
Laboratory analytic method name or description.
Default to ^unknown* if the information is not available.
Table A-16
15
analysisdate
Datetime
Required
Date of sample analysis. Should refer to either beginning or end time
of the analysis as required by EPA. Please report the analysis date as
the collection date plus 30 days where the analysis date is unknown, or
with another approximate date if a more accurate estimated date of
analysis is known. For measurements taken in the field (e.g., pH,
dissolved oxygen), use the same date as sample date (see Pos# 8).
Whenever an approximate date is used, document the way the date was
determined in the comment field (column 36 of this EDD file) and in
the cover letter that accompanies the EDD. Analysis date cannot
precede the sample date.
MM/DD/YYYY
format
Basic Manual for Electronic Data
Version 4.2
22
USEPA Region 5
March, 2019
-------
Table 3-4. Basic Chemistry sample (EPAR5_BasicCHEM_v3) file data structure
Pos#
Column Name
Data Type
Required
Description
Valid Values
In Appendix
16
T otalordissolved
Text (1)
Required
Enumeration list contains the values
A-24
17
testtype
Text (10)
Required
Type of test. Valid values include "initial," "rccxtractl.« ¦reextract2..
¦reextract3," "reanalysis," ¦dilution 1.. «diluton2,. and ¦dilutonS,.
Use "initial" if unknown or data is from measurements taken in the
field (e.g., Ph, dissolved oxygen).
A-25
18
labmatrixcode
Text (3)
If available
Code that identifies the matrix, such as soil, groundwater, and
sediment, being sampled.. This field is included because the matrix of
the sample as analyzed in the lab may differ from the matrix in which it
arrived at the lab (e.g., TCLP leachate samples).
Table A-l
19
analysislocation
Text (2)
Required
Must be either "FI" for field instrument or probe (i.e, "in the field"
measurements such as Ph, temperature, conductivity, and dissolved
oxygen), "FL" for mobile field laboratory analysis, or "LB" for an
analysis done at a laboratory.
FI = field instrument
or probe
FL = mobile field
lab analysis
LB = lab analysis
20
basis
Text (10)
Not required
Must be either "wet" for wet weight basis reporting, "dry" for dry
weight basis reporting, or "NA" for tests for which this distinction is
not applicable. EPA prefers that results be reported on the basis of dry
weight. Default to null if data are not available.
Wet
Dry
NA
21
dilutionfactor
Number w/
precision of
up to 7
Not required
Effective test dilution factor. Default to null if data are not available or
is not applicable.
No
22
qclevel
Text (10)
Not required
Not limit to "Screen" or "Quant", visit Appendix B in the
httDs://semsDub.eDa.gov/work/HO/176101.Ddf for more
values
No
23
labsampleid
Text (20)
Not required
Laboratory LIMS sample identifier. If necessary, a field sample may
have more than one LIMS lab sample id (maximum one per each test
event). Default to null if data are not available.
No
Use "UNKNOWN"
for historical data.
24
casrn
Text (15)
Required
Analyte code.
Table A-15
Basic Manual for Electronic Data 23 USEPA Region 5
Version 4.2 March, 2019
-------
Table 3-4. Basic Chemistry sample (EPAR5_BasicCHEM_v3) file data structure
Pos#
Column Name
Data Type
Required
Description
Valid Values
In Appendix
25
chemicalname
Text(75)
Required
Chemical name
Table A-15
26
resultvalue
Numeric
Not required
Analytic result reported using an appropriate number of significant
digits. Insert ¦null, for non-detect results.
* Required if detect flag = Y and result type code = «TRG. or aTIC.
No
27
resulttypecode
Text (10)
Required
Should be either "TRG" for a target or regular result, "TIC" for a
tentatively identified compound, "SUR" for a surrogate, "IS" for an
internal standard, or "SC" for spiked compound. Provide definitions if
other codes are used. Use "TRG" for data from field measurements.
No
28
reportableresult
Text (10)
Required
Must be either "Yes" for results that are considered reportable, or "No"
for other results. This field can be used to distinguish between multiple
results when a sample is retested after dilution. It can also be used to
indicate which of the first or second column result should be
considered primary. In both examples, the proper value for this field
should be provided by the laboratory, i.e., only one result should be
flagged as reportable.
Yes
No
Y
N
29
detectflag
Text (2)
Required
Enter "Y" for detected analytes and for estimated results above
detection limit but below the quantitation limit. Enter "N" for non-
detects. For tests such as flash point, use ">" and "<" [Note do not use
"<" to indicate non-detects.]
Y=detected
N=non detected
= flash point
30
labqualifiers
Text (10)
Not Required
Qualifier flags assigned by the laboratory. Definitions must be
provided in comment field (field 36) and in EDD cover letter for all
qualifiers which do not appear in the list of valid values.
Table A-10
31
validatorqualifiers
Text (10)
Not required
Qualifier flags assigned by the person who validates the data received
from the lab. Definitions must be provided in comment field and cover
letter for all qualifiers if valid values are not used.
Table A-10
Basic Manual for Electronic Data
Version 4.2
24
USEPA Region 5
March, 2019
-------
Table 3-4. Basic Chemistry sample (EPAR5_BasicCHEM_v3) file data structure
Pos#
Column Name
Data Type
Required
Description
Valid Values
In Appendix
32
Interpretedqualifier
Text(20)
If available
Interpreted qualifier flag assigned by the validator. When the
validated_yn = N (no, meaning the data is not validated by validator),
the interpret qualifier is required if labqualifier or validator qualifier
are populated. If the validated_yn = Y (yes, meaning the data has been
validated and the validator agreed witht eh lab qualifier), then they
should populate the validator qualifier and the interpreted qualifier. If
the validated_yn = Y (yes, but the validator does not agree with the
lab qualifier), then the validator will leave the qualifier NULL and the
final qualifier is also NULL. When populating th e
interpreted qualifier, please use the qualifier in the Valid Value in A-
10 with the description that can closely match with the lab qualifier.
Table A-10
33
validated_yn
Text (1)
Required
Must be either "Y" for validate or "N" for not validate.
Indicate if the data
has been validated
34
Organic_yn
Text (1)
Required
Must be either "Y" for organic constituents or "N" for inorganic
constituents
35
reporting_detection_
limit
Numeric
Not required
Concentration level above which results can be quantified with
confidence. Required if result is a non-detect (i.e., detect flag = 'N').
The value must reflect conditions such as dilution factor and moisture
content and must be sample-specific. Required for all results for which
such a limit is available. If the detection limit is unknown, enter null as
the detection limit and record ¦detection limit unknown, in the
comment field (field 36). [The value entered in this field should be the
sample-specific detection limit Do not enter the contract required
quantitation limit (CRQL) in this field. This value cannot be negative
unless one of the radiological fields (minimum detectable conc,
counting error, uncertainty, critical value) are populated.
No
36
resultunit
Text (15)
If available
Unit of measurement for the result
Table A-18
Basic Manual for Electronic Data 2^ USEPA Region 5
Version 4.2 March, 2019
-------
Table 3-4. Basic Chemistry sample (EPAR5_BasicCHEM_v3) file data structure
Pos#
Column Name
Data Type
Required
Description
Valid Values
In Appendix
37
detectionlimitunit
Text (15)
If available
Unit of measurement for the detection limit. This field is required if a
value other than null appears in the reporting detection limit field.
Table A-18
38
method_detection_
limit
Text(20)
Not required
Report as null. The minimum concentration of an analyte that can be
measured and reported with 99% confidence that the analyte
concentration is greater than zero, as determined for a specific
procedure.
No
39
quantitationlimit
Text(20)
Not required
Concentration level above which results can be quantified with
confidence. The value must reflect conditions such as dilution factors
and moisture content, and must be sample-specific.
No
40
taskcode
Text(40)
Required
Code used to identify the task under which the field sample was
retrieved. The format for this field is the date the sampling task started
(vvYv/mm/dd)
No
41
Task_phase
Text (50)
Not required
This field is associated with the task code. Possible enteries would be
Pre remedial, Remedial Investigation, Feasibility Study.
No
42
Resultcomment
Text (255)
Not required
Result specific comments
No
3.5 Basic Water Level EDD File
The Basic Water Level EDD file includes information on water level measurements collected at the site over the years. Groundwater
levels and surface water elevations should be reported using this file; however, in most cases, the file will be used to report
groundwater levels. All fields in the Basic Water Level file should be populated for groundwater elevation data (if data is available).
Each Basic Water Level file containing historical data should be named according to the following convention:
Date.EPAIDCode.EPAR5_BasicWTR_v3.txt (or .csv)
Basic Manual for Electronic Data
Version 4.2
26
USEPA Region 5
March, 2019
-------
Table 3.5. Basic Water Level (EPAR5_BasicWTR_v3) file data structure
Pos#
Column Name
Data Type
Required
Description
Valid Values
In Appendix
1
sysloccode
Text (20)
Required
Sample location ID, such as MW-01, from which water level
measurement was collected. Must be the same sys loc code
as reported in the Location EDD file.
No
2
measurementdate
DateTime
Required
Date of water level measurement. If exact date is not known,
enter the best estimate for the date of sampling. If an
estimated date is entered, note this and provide an explanation
for how the estimate was made in both the EDD cover letter
and in the comment field in this file (field 10).
MM/DD/YYYY
format
3
Historicalreferencee
lev
Number with
precision of
up to 15
Required
Historical reference value. Used for the elevation of past
reference points. Elevation must be in feet.
No
4
waterleveldepth
Number with
precision of
up to 7
Not required
Water level depth in feet below the reference elevation.
Default to null if data are not available.
No
5
waterlevelelev
Number with
precision of
up to 7
Not Required
Water level elevation in feet below the reference elevation.
Default to null if data are not available.
No
6
measured depth of w
ell
Number with
precision of
up to 7
Not Required
Depth below ground surface to bottom of well. Default to null
if data are not available.
No
7
depth_ unit
Text (15)
if available
Unit used for depth and elevation measurements..
Table A-18
8
remark
Text (255)
Not required
Remark or comment on measurement. Default to null where
the data are not available.
No
9
dry_indicator_yn
Text (1)
Not required
Enter «Y. if the well was dry and «N. if it was not dry.
Default to null if data are not available.
Y= dry
N=not dry
10
Lnaplcasrn
Text (15)
If available
Analyte code of the light non-aqueous phase liquid (lnapl)
present in the well. Use appropriate valid value from Table A-
15 in the EDD Specification Manual Valid Value Appendix.
Table A-15 (a drop
down with cas
number and
chemical name)
Basic Manual for Electronic Data
Version 4.2
27
USEPA Region 5
March, 2019
-------
Table 3.5. Basic Water Level (EPAR5_BasicWTR_v3) file data structure
Pos#
Column Name
Data Type
Required
Description
Valid Values
In Appendix
11
Lnapldepth
Text Number
with precision
of up to 7
Not required
Depth to the top surface of the lnapl in feet below the
reference elevation.
No
12
Dnaplcasrn
Text (15)
If available
Analyte code of the dense non-aqueous phase liquid (dnalp)
present in the well..
Table A-15 (a drop
down with Cas
number and
chemical name)
13
Dnapledepth
Number with
precision of
up to 7
If available
Depth to the top surface of the dnapl in feet below the
reference elevation
No
14
Taskcode
Text(40)
Required
Code used to identify the task under which the field sample
was retrieved. The format for this field is the date the
sampling task started (yyyy/mm/dd)
No
3.6 Basic Geology EDD File - Optional
The Field file contains general information on basic geology data collected at and in the vicinity of the site.
The historical Geology EDD file should be named according to the following naming convention:
Date.EPAIDCode.EPAR5_BasicGEO_v3.txt (or .csv).
Table 3-6. Basic Geology (EPAR5_BasicGEO_v3) file data structure
Basic Manual for Electronic Data
Version 4.2
28
USEPA Region 5
March, 2019
-------
Valid Values
Pos#
Column Name
Data Type
Required
Description
In Appendix
1
sysloccode
Text (20)
Required
Sample location ID, such as MW-01. Must be the same
sys loc code as reported in the Location EDD file.
No
2
startdepth
Number
w/precision
up to 15
Required
Start depth of the geologic unit in feet below ground
surface.
No
3
materialtype
Text(40)
If available
The type of material that composes the lithologic unit.
Acceptable valid values are listed in Table A-18 of the
EDD Valid Values Manual. Must be filled in all cases
except if a depth-specific comment is being made.
A-18
4
geounitcodel
Text (20)
Required
The data providers interpretation of the hydrogeologic
unit. This field may be used to indicate the geologic unit in
terms of general hydrostratigraphy (e.g., aquiferl,
aquiclude, aquifer2) or in terms of a grouping of lithologic
layers (e.g., fill, clay, gravel). Examples of possible
geologic groupings are provided in Figure A-2 of the EDD
Specification Manual.
A-13
5
geo_unit_code_2
Text (20)
If available
Alternate geologic unit grouping. This can be a sub-
classification of geologic unit code l or a layer used for
groundwater flow and/or transport computer modeling that
contains the lithologic unit. Examples of possible geologic
groupings are provided in Figure A-2 of the EDD
Specification Manual.
A-13
6
remarks
Text (255)
Not required
General remarks concerning the lithologic or geologic
unit(s).
No
Basic Manual for Electronic Data
Version 4.2
29
USEPA Region 5
March, 2019
-------
Attachment 1
EXAMPLES OF EDD FILES
Basic Manual for Electronic Data
Version 4.2
30
USEPA Region 5
March, 2019
-------
EXAMPLES OF EDD FILES READY FOR CONVERSION TO TEXT FILES
Examples of EDD files with the first few rows of the EDD populated with a typical data set are presented in Figures 1 through 7. These
examples were produced using Excel worksheets. To submit these files, the data provider would save the files as text delimited files (txt)
or comma separated files (csv) (see section 2.1), check the files using the EDP (see section 2.11), and then send the error free files to Region
5. In order to fit the examples on one page, not all of the fields (i.e., columns) were included for certain files (e.g., Site, Location, and Basic
Chemistry Result). The notation "Additional Fields " has been inserted where, for purposes of these examples, one or more fields have been
omitted. It should be noted that all fields must appear in the EDD files you submit regardless of whether or not the field is populated (see
Section 2.5 regarding reporting blanks, or "null" values).
Figure 1. Example of Subfacility File Ready for Conversion to Text File
sitecode
facilityid
sitename
sitetaskcode
sitedescl
site_desc2
contactname
address 1
01
FAC123456723
Example Site
John Smith
23 Main Street
Additional
Fields
email address
abc(S?abd.com
Figure 2. Example of Basic Location (EPAR5_BasicLOC_v3) File Ready for Conversion to Text File
Basic Location (EPAR5_BasicLOC_v3) File:
Dataprovid
er
Facility code
Syslocc
ode
Alternatew
ell id
Xcoord
Ycoord
Surfelev
Coordtyp
e code
Locname
Locdesc
Loctype
DProvider
MID0000000
01
MW-1
566910.48
4514242.
19
730.55
UTM
ZONE 16
MW
DProvider
MLD0000000
01
MW-2
566810.48
4514142.
19
731
UTM Zone
16
MW
DProvider
MLD0000000
01
MW-3
566710.47
4514132.
19
735
UTIM Zone
16
Shallow
well
MW
DProvider
MLD0000000
01
MW-4
566610.44
491212.1
5
735
UTM Zone
16
Deep well
MW
Additional
Fields
remark
Basic Manual for Electronic Data
Version 4.2
31
USEPA Region 5
March, 2019
-------
Figure 3. Example of Basic Chemistry Result (EPAR5_BasicCHEM_v3) File Ready for Conversion to Text File
sys_sample_
code
Sysloc
code
sample_
name
sample_
matrix_
code
sample_
type_
code
sample_
source
parentsamp
lecode
sample_
date
Start_
depth
End_
depth
Depth
unit
Composite
y/n
lab_anl_
method_
name
Analysis date
Total or
disolved
MWO1040198
MW-01
WG
N
Field
01/01/1997
00:00:00
10
12
Ft
SW8240
01/15/1997
D
MW02040198
MW-03
WG
N
Field
01/01/1997
00:00:00
N
SW8240
01/15/1997
D
MW02040198
MW-03
WG
N
Field
01/01/1997
00:00:00
N
SW8240
01/15/1997
D
Figure 3. Example of Chemistry Result (EPAR5_BasicCHEM_v3) File Ready for Conversion to Text File (continued)
test
Lab
analysis
Additional
qc
lab
Additional
Cas rn
Chemical
Result
Result
reportable
Detect
Addition
reporting
type
Matrix
location
Fields
level
sample
Fields
name
value
type
result
flag
al
detection
code
id_
code
Fields
limit
Initial
WG
LB
quant
71-43-2
BENZENE
23.20
TRG
Yes
Y
5
Initial
WG
LB
quant
LAB02
108-88-3
TOLUENE
TRG
Yes
N
100
Reanalysis
WG
LB
quant
1330-20-7
XYLENES
TRG
Yes
N
10
Additional
Fields
Figure 4. Example of Water Level File Ready for Conversion to Tex
sysloccode
syswellid
measurement
date
refelev
waterleveldepth
w aterlevelelev
MW01
MW01
05/10/1997
13:10:00
120.2
31.1
89.1
MW02
MW02
05/10/1997
13:45:00
123.1
34.1
89.0
Additional
Fields
File
remark
Basic Manual for Electronic Data
Version 4.2
32
USEPA Region 5
March, 2019
-------
Figure 5. Example of Basic Geology (EPAR5_BasicGEO_v3) File Ready for Conversion to Text File
sysloccode
startdepth
materialtype
geounitl
geo_unit_2
Remark
MW-03
0
CL
Glacial
AquiferO
MW-03
10
SW
Outwash
Aquifierl
MW-03
23
SP
Outwash
Aquifer2
SB-01
0
ML
Alluvial
AquiferO
Basic Manual for Electronic Data
Version 4.2
33
USEPA Region 5
March, 2019
------- |