You can also contact your Regional EPA air toxics
office at the following numbers:
What Is The Compliance Date?
•	Existing Sources: December 28, 2009.
•	New Sources: Upon initial startup.
What Are The Permitting Requirements?
•	Affected facilities must obtain a Title V
permit.
What Are The Impacts?
• Three glass plants are expected to have to
add controls to comply with the rule.
What Records Are Required?
Reporting:
•	Initial notification and notification of
compliance status (may be combined), due
120 days after promulgation date
•	Initial notification informs EPA that the
facility is subject to the standards.
Notification of compliance status provides
certification of compliance with standards.
•	No ongoing compliance reports to be
required beyond Title V Requirements.
Recordkeeping:
•	Records to include copies of notifications
submitted to EPA, glass production data,
and records of monitoring and inspections.
•	Records to be maintained in a form suitable
and readily available for expeditious review.
Address
States
Website/
Phone Number
Region 1
5 Post Office Square, Suite 100
Mail code: OES04-2
Boston MA 02109-3912
CT, MA,
ME, NH,
RI.VT
www.eca.aov/reaion1
(888) 372-7341
(617)918-1650
Region 2
290 Broadway
New York, NY 10007-1866
NJ, NY,
PR, VI
www.eca.aov/reaion2
(212) 637-4023
Region 3
1650 Arch Street
Philadelphia, PA 19103-2029
DE.MD,
PA, VA,
WV, DC
www.eoa.aov/reaion3
(215) 814-2746
Region 4
Atlanta Federal Center
61 Forsyth Street, SW
Atlanta, GA 30303-8960
FL, NC,
SC, KY
TN, GA,
AL, MS
www.eoa.aov/reaion4
(404) 562-9131
(800) 241-1754
Region 5
77 West Jackson Blvd.
Chicago, IL 60604-3507
IL, IN,
Ml, Wl,
MN.OH
www.eoa.aov/reaion5
(312) 886-6812
(312) 353-6684
(312) 886-6798
Region 6
1445 Ross Avenue
Suite 1200
Dallas, TX 75202-2733
AR, LA,
NM, OK,
TX
www.eoa.aov/reaion6
(800) 887-6063
(214) 665-7250
(214) 665-7224
Region 7
901 North Fifth Street
Kansas City, KS 66101
IA, KS,
MO, NE
www.eoa.aov/reaion7
(800) 223-0425
(913) 551-7003
Region 8
1595 Wynkoop Stt
Denver, CO 80202-1129
CO, MT,
ND.SD,
UT, WY
www.eoa.aov/reaion8
(800) 227-8917*
(303) 312-6460
Region 9
75 Hawthorne Street
San Francisco, CA 94105
CA, AZ,
HI, NV, GU,
AS, MP
www.eoa.aov/reaion9
(415) 947-8715
Region 10
1200 6th Ave.
Suite 900, AWT-107
Seattle, WA 98101
AK, ID
WA, OR
www.eoa.aov/reaion10
(800) 424-4372*
(206) 553-6220
* For sources within the Region only.
For More Information
Copies of the rule and other materials are located at:
http://www.epa.gov/ttn/atw/area/arearules.html
For more information on state requirements, please
contact your state representatives at:
http://www.epa.gov/ttn/atw/area/table_state_contacts.
doc or,
http://www.4cleanair.org/contactUsaLevel.asp
United States	April 2008
Environmental Protection
Agency	www.epa.qov/ttn/atw/eparules, html
Office of Air Quality Planning & Standards (El 43-02)
vvEPA
Summary of Regulations
Controlling Air
Emissions from the
GLASS MANUFACTURING
INDUSTRY
National Emission
Standards for
Hazardous Air
Pollutants
NESHAP
(SUBPART SSSSSS)
Final Rule

-------
GLASS MANUFACTURING
(SUBPART SSSSSS)
What Is An Area Source?
•	Any source that is not a major source.
(A major source is a facility that emits, or
has the potential to emit in the absence of
controls, at least 10 tons per year (TPY) of
individual hazardous air pollutants (HAP) or
25 TPY of combined HAP.)
Who Does This Rule Apply To?
•	Facilities with glass manufacturing furnaces
producing at least 50 tons of glass per year.
Who is Subject to The Rule?
•	Glass manufacturing plants with continuous
furnaces that process urban HAP metals
(As, Cd, Cr, Pb, Mn, Ni) as raw materials
(not including trace materials in non-HAP
raw materials such as sand).
What am I Required to Do?
•	All affected sources must meet one of two
emissions limits. New and existing sources
have different monitoring requirements.
The charts on the following pages explain, in
detail, how all affected glass manufacturers can
comply with the rule.
Initial testing requirement:
• One-time performance test on each furnace
unless the furnace has been tested in the
last 5 years and the previous test
demonstrated compliance.
Monitoring Requirements

Baghouse
ESP
Existing
Inlet temperature monitoring:
record every 15 minutes and
record every 8 hours
ESP monitoring of the secondary voltage and secondary
electrical current to each field of the ESP; measure
every 15 minutes and record every 8 hours
New
Leak detectors
Install CPMS to measure and record the secondary
voltage and secondary current to each field of the ESP
w
0
o
O
Annual inspections of furnace control devices
U)
<
Can submit a request for alternative monitoring under section 60.8 or section 63.8(f)
Emission Limits
Pollutant
Emission Limit*
Particulate Matter
0.2 lb/ton
(0.1 g/kg)
Combined Urban HAP
(As, Cd, Cr, Pb, Mn, Ni)
0.02 lb/ton
(0.01 g/kg)
* Pounds emitted per ton of glass produced.