... A
WaterSense
WaterSense Specification for Tank-Type Toilets
WaterSense® Specification for Tank-Type Toilets
1.0 Scope and Objective
This specification establishes the criteria for a tank-type high-efficiency toilet under the U.S.
Environmental Protection Agency's (EPA's) WaterSense program. It is applicable to:
•	Single flush, tank-type gravity toilets;
•	Dual flush, tank-type gravity toilets;
•	Dual flush, tank-type flushometer tank (pressure-assist) toilets;
•	Tank-type, flushometer tank (pressure-assist) toilets;
•	Tank-type electrohydraulic toilets; and
•	Any other tank-type technologies that meet these performance specifications.
The specification is designed to ensure both sustainable, efficient water use and a high level of
user satisfaction with flushing performance.
2.0 Summary of Criteria
Toilets must meet criteria in three areas:
•	Effective flush volume shall not exceed 1.28 gallons1 (4.8 liters), as specified in
Section 3.0;
•	Solid waste removal must be 350 grams2 or greater, as specified in Section 4.0;
and
•	The toilet must conform to the adjustability and other supplementary
requirements specified in Section 5.0.
3.0 Water Efficiency Criteria
3.1	Single Flush Toilets - The effective flush volume shall not exceed 1.28 gallons
(4.8 liters) when evaluated in accordance with the sampling plan contained in 10
CFR 429.30. For single flush toilets the effective flush volume is the average
flush volume when tested in accordance with ASME A112.19.2/CSA B45.1.3
3.2	Dual Flush Toilets - The effective flush volume shall not exceed 1.28 gallons (4.8
liters) when evaluated in accordance with the sampling plan contained in 10 CFR
429.30. For dual flush toilets the effective flush volume is the composite, average
1	The effective flush volume has been established as 1.28 gallons, which is a 20 percent reduction from the 1.6 gallons per flush
standard that became mandatory pursuant to the 1992 EPAct.
2	A qualified tank-type toilet must provide superior flushing performance while saving significant volumes of water. Based on data
contained in the medical study Variability of colonic function in healthy subjects, 1978, J.B. Wyman, K.W. Heaton, A.P. Manning,
and A.C.B. Wicks of the University Department of Medicine, Bristol Royal Infirmary, the greatest single 'loading' of the 20 study
participants was approximately 450 grams, and the 99.5 percent confidence level of the men in the study equates to a loading of
approximately 350 grams.
3	References to this and other ASME standards apply to the most current version of that standard.
Version 1.1
1
May 20, 2011

-------
... A
WaterSense
WaterSense Specification for Tank-Type Toilets
flush volume of two reduced flushes and one full flush. Flush volumes shall be
tested in accordance with ASME A112.19.2/CSA B45.1 and ASME A112.19.14.
4.0 Flush Performance Criteria
4.1	Toilet model performance is identified as either a Pass or Fail depending upon
whether it can successfully and completely clear all test media from the fixture in
a single flush in at least four of five attempts. Only toilet models that Pass qualify
for EPA's WaterSense label. Flush performance testing shall be conducted in
accordance with the test protocol provided in Appendix A.
4.2	Test media consists of seven test specimens, 50 ± 4 grams each, consisting of
soybean paste forming a 'sausage' approximately 4 ± 0.5 inch (100 ± 13 mm) in
length and 1 ± 0.25 inch (25 ± 6 mm) in diameter and four loosely crumbled balls
of toilet paper as defined in Appendix A.
4.3	The flush performance criteria apply to single flush toilets, and to the full flush
option of dual flush toilets. No solid waste removal requirement applies to the
reduced flush option on dual flush toilets.
5.0 Supplementary Requirements for Flush Volume Adjustability
5.1	All single flush toilets must conform to ASME A112.19.2/CSA B45.1 and all dual
flush toilets must conform to ASME A112.19.14.
5.2	The criteria in this section apply to tank-type gravity toilets.
5.2.1	Must conform to ASME A112.19.5.
5.2.2	Fill Valve
The fill valve shall be the pilot valve type only, or, alternatively, the fill
valve shall meet the performance requirements of the fill valve test
protocol in Appendix B. All fill valves must conform to ANSI/ASSE 1002.
5.2.3	Tank Capacity
5.2.3.1	Any barrier, bucket, dam, displacement device, or similar fixture
used in a toilet tank to affect flush volume shall be tamper-
resistant and permanently affixed to the tank. Any device that
can be tampered with or removed such that the toilet can be
made to flush with greater than the maximum flush volumes
specified in Section 5.2.3.2 shall be deemed noncompliant.
5.2.3.2	The maximum volume of water that may be discharged by the
toilet, when field adjustment of the tank trim is set at its
maximum water use setting, shall not exceed the following
amounts:
• For single flush fixtures: 1.68 gallons (6.4 liters) per flush4
4 Value based on a maximum effective flush volume of 1.28 gallons (4.8 liters), with no more than 0.40 gallon (1.6 liter) increase with
tank trim adjusted to maximum water use settings.
Version 1.1
2
May 20, 2011

-------
... A
WaterSense
WaterSense Specification for Tank-Type Toilets
•	For dual flush fixtures: 1.40 gallons (5.3 liters) per flush5 in
reduced flush mode and 2.00 gallons (7.6 liters) per flush6
in full flush mode.
•	The maximum volume of water discharged, using both
original equipment tank trim and using aftermarket closure
seals shall be tested according to the protocol in Appendix
C.
6.0 Product Marking
6.1	Toilet tank trim shall be marked in accordance with requirements in ASME
A112.19.5.
6.2	Toilet tanks shall not be packaged, marked, or provided with instructions
directing the user to an alternative water-use setting that would override the rated
flush volume, as established by this specification. Any instruction related to the
maintenance of the product shall direct the user on how to return the product to
its rated flush volume.
6.3	Toilet bowls may be marked in a manner that indicates compatibility with flush
volumes below 1.6 gallons per flush.
7.0 Effective Date
This specification is effective on May 20, 2011.
8.0 Future Specification Revisions
EPA reserves the right to revise this specification should technological and/or market changes
affect its usefulness to consumers, industry, or the environment. Revisions to the specification
would be made following discussions with industry partners and other interested stakeholders.
9.0 Definitions
Definitions within ASME A112.19.2/CSA B45.1, ASME A112.19.5, and ASME A112.19.14 are
included by reference.
•	Electrohydraulic toilet: A toilet fixture of siphonic or washdown design that uses
a motor, pump, and controller to assist flushing action.
•	Pressure-assist toilet: A flushometer tank toilet as defined in ASME
A112.19.2/CSA B45.1.
•	Rated flush volume: The stated flush volume of the toilet, as certified.
5	Value based on the reduced flush requirement in ASME A112.19.14-2001.
6	Value based on the requirement in the Los Angeles Department of Water and Power Supplementary Purchase Specification,
adopted in 2000 and as amended in 2005.
Version 1.1
3
May 20, 2011

-------
... A
WaterSense
WaterSense Specification for Tank-Type Toilets
Appendix A: Fixture Performance Testing Protocol7
1.0 Scope of Testing
1.1	Toilet model performance is identified as either a Pass or a Fail depending upon
whether the test fixture can successfully and completely clear all media (350
grams) from the fixture in a single flush in at least four of five attempts.
1.2	Tests where toilet sample clogs, plugs, or fails to restore a minimum of a 2-inch
(50 mm) trap seal following each flushing test will be deemed a failed test.
1.3	Test media is comprised of the following:
1.3.1	Seven (7) test specimens at 50 ± 4 grams per test specimen ("test
specimen") consisting of soybean paste forming a "sausage"
approximately 4 ± 0.5 inch (100 ± 13 mm) in length and 1 ± 0.25 inch (25
± 6 mm) in diameter. The total mass of test media used for each test shall
be 350 ± 10 grams.
1.3.2	Four (4) loosely crumpled balls of toilet paper ("paper").
2.0 Testing Protocol
2.1	Set-Up
2.1.1	Samples shall be assembled according to manufacturer's written
instructions as contained within the product packaging, and placed on test
rig, ensuring tank and bowl are level.
2.1.2	Tank water level shall be adjusted to the level specified by manufacturer
in the manufacturer's instructions (e.g., set to waterline) where applicable.
2.1.3	Static water supply pressure shall be set to 50 ± 3 PSIG.
2.1.4	Inlet water temperature shall be 65 to 80°F (18 to 27 °C).
2.1.5	Flush sample a minimum of three times prior to commencement of
testing.
2.1.6	Re-adjust tank water level to proper level if required.
2.2	Flush Volume Measurement
2.2.1	Measure and record flush volume of sample (sample set-up as outlined in
Section 2.1). Repeat the test two additional times and record the results
and the average of the three test replicates. A receiving vessel may be
used, either calibrated in increments not exceeding 0.025 gallon (0.1 liter)
or placed on a load cell with a readout in increments not exceeding 0.025
gallon (0.1 liter). Other methods capable of measuring volumes to within
in 0.025 gallon (0.1 liter) shall be acceptable.
2.2.2	Samples with average flush volumes in excess of 0.10 gallon (0.4 liter)
greater than their rated flush volume shall be deemed to fail testing
requirements due to excessive flush volume.8
7	Testing protocol based on Maximum Performance (MaP) Testing Protocol, Version 3, January 2006, by Bill Gauley, Veritec
Consulting, Inc., and John Koeller, Koeller and Company.
8	For example, fixtures rated at 1.28 gallons per flush (the maximum flush volume) but flushing at greater than 1.38 gallons (5.2 liter)
when adjusted to water line shall be deemed to have "failed" the requirements of this specification.
Version 1.1
A-1
May 20, 2011

-------
... A
WaterSense
WaterSense Specification for Tank-Type Toilets
2.2.3	Samples with average flush volumes less than 0.10 gallon (0.4 liter)
greater than their rated flush volume shall be adjusted, if possible, to their
rated flush volume prior to performance testing.
2.2.4	Samples with average flush volumes less than their rated flush volume
shall be tested at measured volume and this volume shall be recorded on
test report.
2.3 Waste Extraction Test
2.3.1	Test specimens shall be formed such that they are roughly cylindrical in
shape and uniform in diameter.
2.3.2	A test specimen drop guide shall be placed across the top of the bowl,
with the centerline of a 2-inch (50 mm) diameter opening 6 inches (15 cm)
in front of the center of the seat post holes, equidistant from each hole.
Drop guide may be made of plastic or other rigid material, to be no more
than 0.5 inch (12 mm) thick, and be of sufficient length to span top of
toilet bowl.
2.3.3	Seven (7) test specimens (350 grams) shall be freely dropped in a vertical
orientation through opening in drop guide into bowl.
2.3.4	Immediately remove drop guide and freely and randomly drop four balls
of crumpled toilet paper over center of bowl sump.
2.3.5	Wait 10 ± 1 seconds.
2.3.6	Flush sample.
2.3.7	Record test as Pass or Fail (test is a Fail if any waste remains in the
bowl or trap, or if minimum 2-inch (50 mm) trap seal has not been
restored).
2.3.8	Flush sample to clean bowl and trapway and fully restore trap seal.
2.3.9	Repeat testing until toilet sample either (i) achieves four Pass grades or
(ii) achieves two Fail grades.
2.3.10	Models must Pass at least four of five attempts to qualify for EPA's
WaterSense Program.
3.0 Test Media Specifications
3.1	Soybean Paste Nominal Specifications
35.5 percent water, 33.8 percent soybean, 18.5 percent rice, and 12.2 percent
salt, and having a density of 1.15 ± 0.10 gram/milliliter (i.e., density greater than
that of water).
3.2	Test Specimens
Each test specimen shall have a mass of 50 ± 4 grams.
3.3	Toilet Paper Specifications
Each ball of paper is comprised of six sheets of single ply toilet paper conforming
to ASMEA112.19.14, section 3.2.5.1.2.
Version 1.1
A-2
May 20, 2011

-------
... A
WaterSense
WaterSense Specification for Tank-Type Toilets
Appendix B: Fill Valve Integrity Test Protocol9
1.0 Scope of Testing
This requirement shall apply to all fill valves that are not otherwise classified as pilot valves.
Samples must conform to both Sections 2.0 and 3.0 of this appendix.
2.0 Consistent Water Level
2.1	Purpose of Test - To determine whether or not the fill valve shuts off at a
consistent water level in a toilet tank independent of any change in inlet water
supply pressure.
2.2	Test Procedure
2.2.1	Install the fill valve in the toilet tank provided, install the tank on a leveled
test stand, and adjust the water level per the manufacturer's
recommendation at an inlet water pressure of 20 ± 2 PSIG or at the
manufacturer's recommended minimum pressure as noted in the product
literature and product packaging.
2.2.2	Flush the tank to verify and mark water level after completed refill.
2.2.3	Increase the inlet water pressure to 60 ± 2 PSIG.
2.2.4	Flush the tank.
2.2.5	Measure any difference in water level after completed refill.
2.2.6	Repeat steps 2.2.3 to 2.2.5 utilizing 80 ± 2 PSIG inlet water pressure.
2.3	Performance Requirement - The fill valve shall shut off at the same water level ±
0.5 inch (± 12 mm) for all three inlet water pressures. In addition, water shall not
enter the overflow tube or flow out of the tank at any of the three tested inlet
pressures.
3.0 Shutoff Integrity With Increased Water Pressure
3.1	Purpose of Test - To determine whether or not the fill valve shuts off at a
consistent water level in a toilet tank independent of changes in inlet water
supply pressure.
3.2	Test Procedure
3.2.1	Install the fill valve in a toilet tank and adjust the water level per the
manufacturer's recommendation at an inlet water pressure of 20 ± 2 PSIG
or at the manufacturer's recommended minimum pressure as noted in the
product literature and product packaging.
3.2.2	Flush the tank to verify and mark water level after completed refill.
3.2.3	Increase the inlet pressure to the fill valve from 20 (or recommended
minimum pressure) to 60 PSIG, then to 80 PSIG at a rate of less than 10
PSIG per second.
9 Testing protocol based on Appendix B to Los Angeles Department of Water and Power Supplementary Purchase Specification,
November 16, 2005 version.
Version 1.1
B-1
May 20, 2011

-------
A
EPA
Water Sense	WaterSense Specification for Tank-Type Toilets
3.3 Performance Requirement - The water level shall remain at the initial mark ± 0.5
inch (± 12 mm). In addition, water shall not enter the overflow tube or flow out of
the tank.
Version 1.1
B-2
May 20, 2011

-------
... A
WaterSense
WaterSense Specification for Tank-Type Toilets
Appendix C: Tank Trim Adjustability Testing Protocol10
1.0 Scope of Testing
All tank-type gravity toilet fixtures must conform to the requirements of Section 2.0 of this
appendix, which address the adjustability of original equipment tank trim and the resulting flush
volume of the toilet fixture. All tank-type gravity toilet fixtures with flush seals must conform to
the requirements in Section 3.0 of this appendix, which address the flush volume resulting from
the replacement of original equipment seals with seals available in the aftermarket.
2.0 Tank-Type Gravity Toilets With Original Equipment
2.1	Purpose of Test - The objective of this tank trim adjustability test is to determine
the upper limit to the volume of water that may be discharged by the field
adjustment of tank trim components. The maximum volume of water that may be
discharged by the toilet, when field adjustment of original equipment tank trim is
set at its maximum water-use setting, shall not exceed the following amounts:
For single flush fixtures - 1.68 gallons (6.4 liters) per flush
For dual flush fixtures:
Reduced flush ("short flush") mode - 1.40 gallons (5.3 liters) per
flush
Full flush mode - 2.00 gallons (7.6 liters) per flush
The following test procedure shall be used to verify that the toilet sample meets
these requirements.
2.2	Test procedure - Test shall be conducted per section 8.4 of ASME
A112.19.2/CSA B45.1 with the following modifications:
2.2.1	The toilet shall be installed on a leveled test stand and all adjustable tank
trim components (any field adjustment features in the tank that might
increase the toilet flush volume) shall be adjusted to the maximum water
use setting, while taking care not to damage or alter the parts.
2.2.2	The water level in the tank shall be set to 0.25 ± 0.06 inch (6 ± 2 mm)
below the top of the overflow tube. Where the tank utilizes an internal
containment vessel and does not possess an overflow tube, the vessel
shall be filled to a level 0.25 ± 0.06 inch (6 ± 2 mm) below the top rim of
the vessel or to the manufacturer's designated water line, whichever is
higher.
2.2.3	The static pressure of the water supply shall be adjusted to 80 ± 2 PSIG.
2.2.4	The toilet shall be flushed maintaining the activator in the flushing position
for a period of one (1) second, the water being drained into a container.
2.2.5	After the flush cycle is complete, the total flush volume shall be observed
and recorded.
2.2.6	This procedure shall be repeated until five (5) sets of data are obtained.
2.2.7	The static pressure of the water supply shall be adjusted to 20 ± 2 PSIG
or at the manufacturer's recommended minimum pressure as noted in the
10 Testing protocol based on Los Angeles Department of Water and Power Supplementary Purchase Specification, 16 November
2005 version, modified to reflect the deletion of certain trim durability and marking requirements incorporated into ASME A112 19.5.
Version 1.1
C-1
May 20, 2011

-------
... A
WaterSense
WaterSense Specification for Tank-Type Toilets
product literature and product packaging, and test procedure steps 2.2.4
to 2.2.6 shall be repeated.
2.2.8 For dual-flush toilet fixtures, this test shall be conducted at both full flush
and reduced flush modes.
2.3	Report - The five (5) individual flush volumes and the average of the five (5) runs
shall be reported for each of the two static water supply pressures specified.
2.4	Performance Requirement - The average total flush volume for five (5) test runs
for each of the two static water supply pressures shall not exceed the following:
For single-flush fixtures - 1.68 gallons (6.4 liters) per flush
For dual-flush fixtures:
Reduced flush ("short flush") mode - 1.40 gallons (5.3 liters) per
flush
Full flush mode - 2.00 gallons (7.6 liters) per flush
The volume of water may be determined visually using a graduated container or
by weight calculated as a unit to volume unit.
3.0 Tank-Type Gravity Toilets With Aftermarket Closure Seals
3.1	Purpose of Test - The objective of this tank trim adjustability and aftermarket
seal test is to determine the upper limit to the volume of water that may be
discharged when an off-the-shelf replacement flush valve seal/flapper is installed
on the toilet. The maximum volume of water that may be discharged by the toilet,
when the original equipment flush valve seal (flapper or other sealing device) is
replaced with a standard (buoyant) seal available in home improvement centers
and hardware stores, and the field adjustment of tank trim is set at its maximum
water-use setting, shall not exceed the following amounts:
For single flush fixtures - 1.68 gallons (6.4 liters) per flush
For dual flush fixtures:
Reduced flush ("short flush") mode - 1.40 (5.3 liters) gallons per
flush
Full flush mode - 2.00 gallons (7.6 liters) per flush
The following test procedure shall be used to verify that the toilet sample meets
these requirements.
3.2	Test procedure - Test shall be conducted per section 8.4 of ASME
A112.19.2/CSA B45.1 with the following modification:
3.2.1	The toilet shall be installed on a leveled test stand and all adjustable tank
trim components (any field adjustment features in the tank that might
increase the toilet flush volume) shall be adjusted for maximum water
use, while taking care not to damage or alter the parts.
3.2.2	Remove the original equipment flush valve seal and replace it with a
standard (buoyant) aftermarket seal/flapper for that toilet where possible.
For any ongoing surveillance testing, the same model replacement flush
Version 1.1
C-2
May 20, 2011

-------
... A
WaterSense
WaterSense Specification for Tank-Type Toilets
valve seal shall be used as was used during the initial product testing and
certification.11
3.2.2.1	Two-inch flush valves - In the case of a standard configuration 2-
inch flush valve, a non-adjustable Fluidmaster Bullseye Super
flapper (part no. 501) or a Coast Foundry Ultra Blue flapper shall
be used.
3.2.2.2	Three-inch flush valves - In the case of a standard configuration
3-inch flush valve, an adjustable Lavelle Korky model 3060 flapper
shall be used. The flapper shall be adjusted in accordance with
the flapper manufacturer's instructions to provide the rated flush
volume of the toilet.
3.2.2.3	Non-standard flush valves - In the case of non-standard flush
valves, one or more replacement seals available at hardware,
plumbing supply, and building supply stores or from the
manufacturer or other recognized source shall be used.12
3.2.3	The water level in the tank shall be set to 0.25 ± 0.06 inch (6 ± 2 mm)
below the top of the overflow tube. Where the tank utilizes an internal
containment vessel and does not possess an overflow tube, the vessel
shall be filled to a level 0.25 ± 0.06 inch (6 ± 2 mm) below the top rim of
the vessel or to the manufacturer's designated water line, whichever is
higher.
3.2.4	The static pressure of the water supply shall be adjusted to 80 ± 2 PSIG.
3.2.5	The toilet shall be flushed maintaining the activator in the flushing position
for a period of one (1) second maximum, the water being drained into a
container.
3.2.6	After the flush cycle is complete, the total flush volume shall be observed
and recorded.
3.2.7	This procedure shall be repeated until five (5) sets of data are obtained.
3.2.8	The static pressure of the water supply shall be adjusted to 20 ± 2 PSIG
or at the manufacturer's recommended minimum pressure as noted in the
product literature and product packaging, and test procedure steps 3.2.5
to 3.2.7. shall be repeated.
3.2.9	For dual-flush toilet fixtures, this test shall be conducted at both flush
modes (full flush and reduced flush).
3.3	Report - The five (5) individual flush volumes and the average of the five (5) runs
shall be reported for each of the two static water supply pressures specified.
3.4	Performance Requirement - The average total flush volume for five (5) test runs
for each of the two static water supply pressures shall not exceed the following:
For single-flush fixtures - 1.68 gallons (6.4 liters) per flush
For dual-flush fixtures:
Reduced flush ("short flush") mode - 1.40 gallons (5.3 liters) per
flush
11	If during the ongoing surveillance testing the type of replacement flush valve seal used in the initial product testing is no longer
available, then the manufacturer no longer has to comply with Section 3.0 of Appendix C.
12	In the case of a toilet fixture with a non-standard flush valve seal, the testing laboratory shall have discretion as to which
aftermarket flapper or seal shall be used in the test.
Version 1.1	C-3	May 20, 2011

-------
... A
WaterSense
WaterSense Specification for Tank-Type Toilets
Version 1.1
Full flush mode - 2.00 gallons (7.6 liters) per flush
The volume of water may be determined visually using a graduated container or
by weight calculated as a unit to volume unit.
C-4
May 20, 2011

-------
... A
WaterSense
WaterSense Specification for Tank-Type Toilets
Appendix D: Requirements for WaterSense Labeling
The following requirements must be met for products to be marked with the WaterSense label.
1.0 WaterSense Partnership
The manufacturer of the product must have a signed partnership agreement in place with EPA.
2.0 Conformity Assessment
Conformance to this specification must be certified by an EPA licensed certifying body
accredited for this specification in accordance with the WaterSense Product Certification
System.
3.0 Clarifications
3.1	Adjustability
Toilet tanks with adjustable water-use settings that can be identified and activated by a
user or plumbing professional to override the rated flush volume, as established by this
specification, do not comply with the intent of this specification or the WaterSense
program and do not qualify for use of the WaterSense label.
3.2	Tanks and Bowls Manufactured and Sold by Different Companies
WaterSense requires every combination tank and bowl to be tested and certified for
conformance to this specification in order to ensure that the toilet as a whole provides
the expected water efficiency and performance. Wall hung bowls and in-wall carrier
systems manufactured and sold by different companies may earn the WaterSense label,
provided that the combination unit is tested and certified. However, since these products
may not necessarily be sold as a unit, WaterSense has established some additional
certification requirements that these products must meet in order to earn the
WaterSense label. Both manufacturers must agree to have their products tested and
certified together in order for the tank and bowl combination to receive the WaterSense
label.
Certification Listing
In order to control the use of the WaterSense label, EPA is requiring each manufacturer
(e.g., the tank manufacturer and the bowl manufacturer) to obtain a certification listing
with one of EPA's licensed certifying bodies to show that the toilet, formed by the
combination tank and bowl, was certified for conformance to the specification. The
listings must identify both components along with the respective manufacturers' names,
brand names, model names, and model numbers by which the products are identified
and sold. Separate listings will allow the licensed certifying body to directly authorize
each manufacturer to use the WaterSense label on their tanks or bowls. Note that
though a certification listing is required for each manufacturer, WaterSense is not
Version 1.1
D-1
May 20. 2011

-------
... A
WaterSense
WaterSense Specification for Tank-Type Toilets
requiring the combination toilet to be tested more than once. The licensed certifying
body must ensure that the listing information is complete prior to issuing the certification
and the WaterSense label to either manufacturer.
As an alternative to separate listings, and at the discretion of the licensed certifying
body, the manufacturer of one of the components (e.g., either the tank or bowl
manufacturer) may become listed as an additional company under the certification listing
of the manufacturer of the corresponding component (e.g., the bowl or tank). However,
both components, along with the respective manufacturer's names, brand names, model
names, and model numbers by which the products are identified and sold, must be
identified under both the certification file owner's listing and the additional company's
listing. This will ensure that there is no confusion about which products were certified in
combination to earn the WaterSense label.
3.3 Product Packaging Marking and Labeling
Though every combination tank and bowl must be tested and certified for conformance
to this specification in order to ensure that the toilet as a whole provides the expected
water efficiency and performance, in some cases the tank and bowl may be packaged
individually and/or sold separately. To ensure that it is clear to the purchaser that a
particular combination tank and bowl is labeled, EPA is providing clarification regarding
how the packaging must be marked and how the WaterSense label must be used.
These marking and labeling requirements apply to tanks and bowls made by the same
company and those made by different companies, as is the case for some wall-hung
bowls and in-wall carrier systems.
Manufacturers must adhere to the following product packaging marking and labeling
requirements for toilet tanks and bowls packaged and sold individually:
•	In all cases the toilet tank packaging must bear the WaterSense label.
•	If the toilet bowl packaging is marked ONLY with the rated flush volume, as
established by this specification, the toilet bowl packaging must bear the
WaterSense label.
•	If the toilet bowl packaging is marked in a manner that indicates compatibility with
flush volumes other than the rated flush volume, as established by this
specification, the manufacturer may NOT use the WaterSense label on the toilet
bowl packaging.
•	Toilet bowl packaging must indicate all of the specific brand names, model
names, and model numbers, as applicable, of the counterpart tanks it may be
used with to form a WaterSense labeled tank- type toilet. For example, the toilet
bowl packaging may say:
"This [insert description of bowl] is WaterSense labeled when used with
[list brand names, model names, and model numbers, as applicable, of
the tank(s) that the bowl may be used with to form a WaterSense labeled
tank-type toilet]."
•	Product specification sheets or other product documentation for both the toilet
tank and bowl must indicate all of the specific brand names, model names, and
model numbers, as applicable, of the counterpart products (e.g., the bowl or
Version 1.1
D-2
May 20. 2011

-------
... A
WaterSense
WaterSense Specification for Tank-Type Toilets
tank) that the product may be used with to form a WaterSense labeled tank-type
toilet.
Note that for toilet tanks and bowls packaged and sold together as a unit, the packaging
must bear the WaterSense label.
Version 1.1	D-3	May 20. 2011

-------