EPA's Responses to Public Comments on EPA's National Emission
Standards for Hazardous Air Pollutants from Coal- and Oil-Fired Electric

Utility Steam Generating Units
December 2011

Volume 2 of 2

Comments, letters, and transcripts of the public hearings are also available electronically through
http://www.regulations.gov by searching Docket ID EPA-HQ-OAR-2009-0234.


-------
FOREWORD

This document provides the EPA's responses to public comments on the EPA's Proposed National
Emission Standards for Hazardous Air Pollutants from Coal- and Oil-fired Electric Utility Steam
Generating Units and Standards of Performance for Fossil-Fuel-Fired Electric Utility, Industrial-
Commercial-Institutional, and Small Industrial-Commercial-Institutional Steam Generating Units. The
EPA published a Notice of Proposed Rulemaking in the Federal Register on May 3, 2011, at 76 FR
24976. The EPA received comments on this proposed rule via mail, e-mail, facsimile, and at three public
hearings held in Chicago, Illinois; Atlanta, Georgia; and Philadelphia, Pennsylvania, in May 2011.
Copies of all comments submitted and transcripts for the public hearings are available at the EPA
Docket Center Public Reading Room. Comments, letters, and transcripts of the public hearings are also
available electronically through htty://www.regulations, gov by searching Docket IDs EPA-HQ-OAR-
2009-0234 (NESHAP action) and EPA-HQ-OAR-2011-0044 (NSPS action).

This document contains responses to comments on the NESHAP only; responses to comments on the
NSPS action are in a separate Response to Comments document. Due to the size and scope of this
rulemaking, the EPA summarized a limited amount of major comments in the preamble of the final rule.
This document contains a summary of all significant comments provided by each commenter extracted
from the original letter or public hearing transcript.

Appendix A of this document provides a list of public hearing speakers and their affiliation. Appendix B
of this document provides a list of commenters and their affiliation along with the associated document
control number (DCN). For each comment, the DCN is provided along with the comment summary. For
purposes of this document, the text within the comment summaries was provided by the commenter(s)
and represents their opinion(s), regardless of whether the summary specifically indicates that the
statement is from a commenter(s) (e.g., "The commenter states" or "The commenters assert"). The
comment summaries do not represent the EPA's opinion unless the response to the comment specifically
agrees with all or a portion of the comment. In some cases the same comment was submitted by two or
more commenters through submittal of a form letter prepared by an organization, by the commenter
incorporating by reference the comments in another comment letter, or by the commenter providing
identical or similar language independently. Rather than repeat these comment excerpts for each
commenter, the EPA has listed the comment excerpt only once and provided a list of all the commenters
who submitted the same form letter or otherwise incorporated the comments by reference in Tables 9A-
1 through 9A-21 and 9B-1 through 9B-5 of section 9 of this document and Table 10-1 of section 10 of
this document, respectively.

Several of the EPA's responses to comments are provided immediately following each comment
summary. However, in instances where several commenters raised similar or related issues, the EPA has
grouped these comments together and provided a single response after the last comment summary in the
group. In some cases, the EPA provided responses to specific comments or groups of similar comments
in the preamble to the final rulemaking. Rather than repeating those responses in this document, the EPA
has referenced the preamble or the appropriate technical support document for a description of the
analysis included in the final rule.

As both the NESHAP and NSPS actions were included in the same proposal package, many commenters
submitted comments to this rulemaking docket that were specific to the NSPS action. Some commenters
submitted a single DCN with comments on both rules, while others submitted a separate DCN specific
to each action. Many commenters submitted identical comments to both dockets. In order to reduce
duplicative comments, we have removed from this document comments associated with the NSPS

1


-------
action. For this reason, the EPA encourages the public to read the Response to Comment document
prepared for the NSPS action.

2


-------
TABLE OF CONTENTS

CHAPTER CHAPTER 5: COMPLIANCE WITH TESTING /MONITORING/

RECORDKEEPING AND REPORTING

5A - Testing/Monitoring

5B - Recordkeeping/Reporting

5C - Compliance

CHAPTER 6: IMPACTS AND COST ANALYSIS

6A - Impacts/Costs: Emission Impacts

6B - Impacts/Costs: Emission Reductions

6C - Impacts/Costs: Energy Impacts

6D - Secondary Impacts

6E - Impacts/Costs: Compliance Costs

6F - Control Technology Cost Assumptions

6G - Impacts/Costs: Testing and Monitoring Cost Assumptions

6H - Impacts/Costs: Projection of New Units

61 - Impacts/Costs: Economic Impacts/Employment Impacts

6J - Impacts/Costs: Social Costs

6K - Impacts/Costs: Health Co-Benefits

6L - Impacts/Costs: Mercury Benefits

6M - Impacts and Costs: Air quality co-benefits modeling

6N - Impacts/Costs: Other/Miscellaneous

CHAPTER 7: STATUTORY AND EXECUTIVE ORDERS

7A - Executive Order 12866, Regulatory Planning and Review and Executive Order 13563,
Improving Regulation and Regulatory Review
7B - Paperwork Reduction Act

7C - Regulatory Flexibility Act (RFA), as Amended by the Small Business Regulatory
Enforcement Fairness Act of 1996 (SBREFA)

7D - Unfunded Mandates Reform Act of 1995
7E - Executive Order 13132, Federalism

7F - Executive Order 13175, Consultation and Coordination with Indian Tribal Governments
7G - Executive Order 13045, Protection of Children From Environmental Health Risks and Safety
Risks

7H - Executive Order 13211, Actions Concerning Regulations That Significantly Affect Energy
Supply, Distribution or Use

71 - National Technology Transfer and Advancement Act

7J - Executive Order 12898, Federal Actions to Address Environmental Justice in Minority
Populations and Low-Income Populations
7K - Statutory and Executive Orders: Other

CHAPTER 8: RULE LANGUAGE CORRECTIONS

8A - Rule: Definitions (existing)

8B - Rule: Definitions (new)

8C - Rule: Corrections to tables

8D - Rule: Language

8E - Rule: Other Language Corrections

3


-------
CHAPTER 9: GENERAL SUPPORT AND GENERAL OPPOSITION
9A - General Support
9B - General Opposition

CHAPTER 10: INCORPORATION BY REFERENCE
APPENDIX A: PUBLIC HEARING PARTICIPANTS
APPENDIX B: LIST OF COMMENTERS

4


-------
CHAPTER 5: COMPLIANCE WITH TESTING/MONITORING/RECORDKEEPING

AND REPORTING

5A01 - Testing/Monitoring: Stack Test Methods

Commenters: 17174, 17191, 17402, 17621, 17623, 17675, 17681, 17696, 17716, 17725, 17729, 17730,
17731, 17747, 17754, 17758, 17767, 17770, 17775, 17790, 17795, 17800, 17807, 17808, 17820, 17821,
17868, 17877, 17878, 17880, 17881, 17975, 18014, 18015, 18021, 18025, 18034, 18428, 18498, 18539,
18935, 18963, 19033, 19536, 19537, 19538, 18932, 18023

1. Comments related to alternative compliance test methods.

Comment 1: Commenter 17775 states that the EPA should allow use of Method 5B and 29 to
demonstrate compliance with the PM limits under the stack testing option. Rather, the commenter
asserts, the EPA proposes to allow use of Methods 5, 5D (required for positive pressure FFs), or 17
(Proposal Table 5). The commenter states that sources performing calibrations of PM CEMS under
Performance Specification (PS) 11, on the other hand, are also allowed the option of using Method 5B -
Determination of Nonsulfuric Acid Particulate Matter Emissions from Stationary Sources. The
commenter states that Method 5B was specifically developed to determine primary filterable PM
emissions from sources with wet scrubbers and is routinely allowed for stack testing under federal
regulations. (40 CFRpart 60, subparts D (section 60.46(b)), Da (section 60.50Da(e)(l)), Db (section
60.46b(d)(2)), Dc (section 60.45c(a)(2)) and part 63, subparts QQQ (section 63.1450(b), UUU (section
63.1579 and tables).) The commenter asserts that the EPA should allow use of Method 5B or explain
why the method is not appropriate for demonstrating compliance with the proposed limits. The
commenter asserts that although the agency's specification of a filter temperature for Method 5 (320° F
+ 25) achieves some of Method 5B's objective, there is no basis for not allowing sources to use a
promulgated test method specifically designed for that purpose. According to the commenter,
prohibiting use of Method 5B could prevent some sources from using tests under subpart UUUUU to
meet other testing requirements without obtaining approval for use of a higher Method 5 filter
temperature in lieu of using Method 5B. Moreover, according to the commenter, evaluation of filterable
PM data from the agency's 2010 ICR database reveal an inconsistency between Method 5 and Method
29 results. The commenter attaches a discussion of and findings on this issue. To the extent the EPA
proposes or promulgates a PM limit that is based in any way on filterable PM results from Method 29,
commenter asserts that the EPA must provide EGUs the option to use Method 29 for any PM testing.

Comment 2: Multiple commenters (17681, 17716, 17725, 17767, 17790, 17795, 17800, 18014) request
that the final rule include the following reference methods in Table 5:

1.	EPA Method 2H,

2.	Conditional Test Method 41 (wall effects adjustment for flow),

3.	EPA Method 26A (HC1 - option for dry stacks),

4.	EPA Method 320 (HC1 - FTIR option),

5.	EPA Method 5B,

6.	EPA Method 17 (total, filterable PM), and

7.	The table should indicate that Method 2 (or equivalent) need only be used if necessary to calculate
output-based emissions.

Response to Comments 1 and 2: The final rule has been amended to allow the use of EPA Methods
2H, 26A and 320 and clarify the requirement of Method 2 (or equivalent) only as necessitated by the

5


-------
calculation of the emission limit. The basis for the filterable PM emissions limit in the final rule is EPA
Method 5 with a filter temperature of 320° F and sample desiccation at temperatures up to 220° F for up
to 3 hours. While Method 5B also specifies a filter temperature of 320° F, Method 5B includes an
additional extended (6 hour) heating of the filter in the laboratory to remove particulate matter that
would volatilize at 320° F including condensed sulfuric acid. This additional analytical step renders the
method unusable for determining compliance with a limit based on Method 5 procedures. As for using
Method 17, we did not cite the method in the rule but would entertain a request for site-specific
alternative method approval to use Mehtod 17 in lieu of Method 5. A condition of approval is that the
stack gas temperature at the sampling location remains no greater than 320° F during the performance
testing.

Comment 3: Several commenters (17767, 17790, 17795, 17800, 17821) state that proposed use of
Method 5 rather than Method 5B in wet stacks is inconsistent with NSPS (e.g., section 60.46(b), section
60.50Da(e)(l), section 60.46b(d)(2), and section 60.45c(a)(2)) and inconsistent with part 63(e.g., section
63.1450(b) and section 63.1579), and the commenters request that the final rule specify the option to use
Method 5B in wet stacks for compliance tests and PM CEM certifications consistent with PS-11.
Commenter 17795 acknowledges that the filter temperatures listed in Table 5 are consistent with Method
5B but points out that filter desiccation temperatures per the proposal would occur at M5 temperatures
(220 °F). Commenter 17795 states that absence of Method 5B from the proposal creates a problem
complying with section 3.20 of PS-11, which defines "reference method" as the method defined in the
applicable regulation, but the method listed in proposed Table 5 is a hybrid method. Commenter 17795
states that inclusion of Method 5B is critical to certification of PM CEMS because all wet particulate
monitors use some type of heated cyclone to vaporize water droplets before analyzing the gas sample,
and the temperature of these cyclones is set to be consistent with the reference method filter
temperature. However, according to this commenter, in order to obtain a final filter weight the reference
method filters must be desiccated, to a constant weight, and proposed Table 5 specifies Method 5, which
by default would require filter desiccation at 220 °F. According to this commenter, since the PM CEMS
sampling process occurs at temperatures above the acid dew point, Method 5B should be followed to
allow filters to be desiccated at the same temperatures as sample collection to minimize inaccuracies for
wet PM CEMS correlations. Commenters (17795, 17800) also believe that making the MACT standard
consistent with the NSPS program and SIP programs will allow the use of a single stack test to satisfy
multiple regulatory requirements and save time, resources, and costs. Commenter 17725 recommends
that the EPA also allow 40 CFR Part 60 Method 2H-Determination of Stack Gas Velocity Taking into
Account Velocity Decay Near the Stack Wall as a valid method for all pollutant types listed in Table 5
to subpart UUUUU of part 63 performance stack testing requirements. The commenter notes that they
utilize Methods 2, 2F, 2G, and 2H for annual volumetric flow monitoring as required across the fleet.

Response to Comment 3: The final rule does not require the certification of the PM CEMS by PS-11.
However, in the event a source wants to be able to use a PM CEMS as a direct method of determining
compliance with the filterable PM emission limits in the final rule, the final rule allows for this option.
Please see the final rule preamble for further discussion.

Comment 4: Commenter 17775 requests that the agency clarify that use of certain methods (Methods 2,
2F, 2G, and 4) are optional because proposed Table 5 lists Methods 2, 2F or 2G as the required methods
to determine the velocity and volumetric flow rate of the stack gas when testing for PM, HC1, and Hg,
and lists Method 4 to determine moisture content for all pollutants, but in some cases, use of these
methods may not be necessary, or reasonable, because all of the methods specified in Table 5 for
concentrations of those emissions also provide measurements of velocity and flow. Likewise, according
to the commenter, the methods used to determine pollutant concentrations (e.g., Methods 5, 23, and

6


-------
26A) also determine stack moisture. The commenter states that the agency should make use of those
methods optional and allow the EGU to determine which method is more appropriate for the specific
test.

Response to Comment 4: The final rule has been amended to clarify that only methodology or
equations required for the specific emission limit will be required.

Comment 5: Commenter 17808 recommends measures be incorporated in the final rule to avoid
running a unit simply to conduct a stack test similar to the approach used in part 75 for defining an
operating quarter and a unit operating hour. Specifically, the commenter recommends incorporation of
the provisions of 40 CFR 72.2 defining a "QA operating quarter" as "a calendar quarter in which there
are at least 168 unit operating hours (as defined in this section) or, for a common stack or bypass stack, a
calendar quarter in which there are at least 168 stack operating hours (as defined in this section)."
According to this commenter, a unit operating hour would be defined as a clock hour during which a
unit combusts any regulated fuel, either for part of the hour or for the entire hour. The commenter
recommends that these definitions apply specifically to the regulated fuels under the EGU MACT rule
(e.g., coal and liquid oil), because by requiring a minimum level of operation to trigger stack testing
requirements, no unit will be operated simply for the sake of testing.

Commenter 17808 recommends an additional, alternative method for demonstrating continuous
compliance for Hg when a unit qualifies for LEE status. As an alternative to conducting monthly fuel
tests, the commenter proposes that owners/operators of a LEE unit have the option to conduct an annual
Method 30B performance test to demonstrate that its emissions are less than 10 percent of its applicable
Hg emissions limit or less than 22.0 pounds per year. If a LEE unit exceeds LEE limits, the commenter
proposes that the unit revert back to more frequent performance tests (e.g., quarterly, as recommended
above). Under this commenter's proposal, in the subsequent year, if the unit can, again, demonstrate
LEE status through reduced utilization or a lower emission rate, it would return to annual stack tests
under the LEE provisions. The commenter recommends this alternative, annual stack testing instead of
monthly fuel testing, to balance the need for accurate emissions data with reduced compliance costs for
those units emitting at a fraction of the proposed standards. Also, in order to avoid having companies
run units simply to conduct stack testing, the commenter proposes that LEE units have the flexibility to
schedule their annual performance tests at any time during a 12-month cycle because some of these
LEEs may be smaller units with low capacity factors and may go several months without operating. The
commenter believes that allowing flexibility in scheduling stack tests will avoid unnecessary HAP
emissions and reduce costs for these units operating well below the proposed standard and believes this
compliance option would allow companies to align testing under this rule with existing state testing
requirements.

Response to Comment 5: The EPA agrees with the comments. The final rule has been amended to
waive testing requirements in a quarter when the unit operates for less than 168 hours, but the source
must under any circumstances test at least once per year.

Comment 6: Commenter 17747 states that they would also like to see the Method 29 monitoring
options (Method 29 testing every 2 months or every month depending on PM control) retained. The
commenter believes that this gives plant operators additional control options and flexibility in achieving
emissions limits.

Response to Comment 6: The final rule has been amended to allow compliance with the non-Hg metals
limit with quarterly Method 29 testing.

7


-------
2.	Comments related to testing period (clarification etc.).

Comment 7: Commenter 17868 states that the final rule should clarify the required testing period in
proposed section 63.10005(k) which specifies 28 to 30 days, but proposed Table 5 specifies 30 days.

Response to Comment 7: The EPA has clarified this issue in the final rule. The required testing period
is 30 days.

Comment 8: Commenter 18539 states that it is not clear in the proposal whether the EPA intends to
require one performance test every 5 years for all surrogates. For example, asserts the commenter,
proposed section 63.10005(d)(4) states that initial compliance for coal-fired units with FGD technology
and SO2 CEMs is determined using the average hourly SO2 concentrations during the first 30-day
operating period, and section 63.10005(d)(5) states the same for PM CEMs. However, according to the
commenter, pages 25051 and 25051 of the preamble and section 63.10005(a) indicate that PM, metals,
S02, and HC1 compliance tests are required initially and every 5 years. According to the commenter,
section 63.10005(a) states that "[I]f you use a continuous monitoring system that measures a surrogate
for a pollutant (e.g., an S02 monitor), you must perform initial emission testing during the same
compliance test period and under the same process (e.g., fuel) and control device operating condition of
the pollutant and surrogate, in addition to conducting the initial 30-day performance test." Additionally,
the commenter states, section 63.10006(a) and (b) state that PM and non-Hg metal HAP, and SO2 and
HC1 emissions testing, respectively, is required at least every 5 years. The commenter requests that the
EPA clarify the intent of the stack testing requirements and give appropriate time to comment on this
requirement.

Response to Comment 8: The final rule has been amended to only require testing and/or monitoring for
the specific emission standard with which the source complies (either the direct emission limit, such as
HC1, or the alternate equivalent standard, such as S02).

Comment 9: Commenter 17775 requests that the agency clarify the required testing period because
proposed section 63.10005(k) refers to a 28-30 operating day performance test and proposed Table 2
similarly requires "LEE testing for 28-30 days." However, according to the commenter, proposed Table
5 requires conversion of emission concentrations to "30 boiler operating day rolling average lb per
MMBtu emission rates or lb/MWh emission rates" (proposed Table 5 (4.f.)). According to the
commenter, if the EPA intends to allow use of 28 days of sorbent trap data (i.e., two 14-day sorbent
traps) to determine the "average Hg concentration" for the performance test, the EPA should make clear
in Table 5 that the values in Table 5 can be derived from 28 days of data.

Response to Comment 9: The final rule has clarified this issue. The required testing period is 30 days.

3.	Comments related to operating parameters and fuel limits set during testing.

Comment 10: Commenter 17775 requests clarifications regarding the proposal's stack testing options
for HAP metals because it is not clear to the commenter whether the agency intended the operating
parameters and fuel input limits in proposed section 63.10011(b) to apply, because on its face, the
requirements of section 63.10011(b) appear to apply to all EGUs, regardless of the compliance option.
However, according to the commenter, that result is not consistent with the agency's expressed
intention. For example, the commenter asserts, in the preamble the EPA says that such operating
parameters do not apply and cites 76 FR 25,029/3 ("Except for liquid oil-fired units, ... we are
proposing that you monitor during initial performance testing specified operating parameters) (emphasis

8


-------
added). However, the commenter states, similar to LEEs, the EPA also suggests that liquid oil-fired
units must meet maximum fuel input limits as an operating limit (citing 76 FR 25,030/2). According to
the commenter, the EPA must make clear in section 63.10011(b) what operating limits apply and issue a
proposal explaining why. The commenter states that if the maximum fuel input limits in section
63.10011(b) apply to liquid oil-fired EGUs opting to demonstrate compliance using stack testing, the
EPA should make clear that EGUs combusting a single fuel type are not required to make any
determination regarding that fuel under section 63.1001 l(b)(2)(i) and (3)(i) (requiring determination that
the fuel type or mixture has the highest content of Hg and of non-Hg HAP metal) and that EGUs using
supplemental fuels qualify as single fuel EGUs. The commenter states that although the EPA has
attempted to address that issue for liquid oil-fired EGUs in section 63.10005(c)(4) and section
63.10011(c)(1), those provisions apply only to liquid oil-fired EGUs complying through fuel analysis.

Comment 11: Commenter 18023 states that the agency must clarify that operating limits and fuel limits
do not apply to sources using CEMS for compliance because the commenter assumes that the purpose of
the operating limits is to demonstrate compliance between regularly scheduled performance tests at units
that are not otherwise continuously monitoring compliance; however, the proposed rule is not clear on
this point. The agency should therefore specify that the operating limits (including the operating load
limit) and fuel limits apply only to units using stack tests to comply.

Comment 12: Commenter 17775 states that the final rule must clarify the operating limit requirements
for control devices and the single fuel EGU requirements for establishing a maximum fuel input for
chlorine under section 63.1001 l(b)(l)(i).

Comment 13: Commenter 17878 states that for units not equipped with CEMS it is appropriate to have
an alternative approach to assure compliance for the periods between stack tests. The EPA proposes to
set enforceable operating limits based on control device parameters measured during performance
testing creates what is effectively a second and more stringent standard. According to the commenter
unit operators will utilize control equipment that is designed to provide a margin of compliance that
provides flexibility for the source to account for small variations in control equipment performance and
fuel characteristics. The result will be "over-compliance" during a periodic stack test, and this is normal.
If operating conditions reflecting this stack test period are then used as a measure of ongoing
compliance, then those expected variations, which do not exceed an emission limit, would become
violations.

Comment 14: Commenter 17868 states that the EPA should re-evaluate the proposed operating
parameter requirements.

Response to Comments 10 -14: The final rule has removed the requirements for operating and fuel
limits, except where a source: (1) opts to use a PM CPMS to monitor compliance; or (2) for a liquid oil-
fired unit, adopts a source-specific monitoring plan to collect, record, and report on appropriate
operational parameters in addition to conducting quarterly performance tests. In addition, the EPA notes
that the final rule allows a source to monitor fuel moisture data to demonstrate compliance with the HC1
and HF standards for liquid oil-fired units (fuel moisture must be no greater than 1.0%). The details of
these options are discussed in the preamble to the final rule and elsewhere in this response to comment
document. There are no operating parameter requirements in situations where a source determines
compliance with an emission limit using a CEMS.

4. Comment related to use of short term stack test and fuel samples to set 30-day standards.

9


-------
Comment 15: Commenter 17402 states that the EPA should not penalize facilities with low emissions
by setting both fuel content and operating limits based on average performance during stack tests
because this methodology effectively sets lower standards. Instead, according to the commenter, the
EPA should set fuel content limits based on the source's contaminant removal effectiveness, so that a
source can use a range of fuels as long as the standard is met. Commenter 17729 is an affected source
operator who discusses stack test results for non-Hg metals and total PM at a unit that will be subject to
the proposed MACT standards. Commenter 17720 states that the stack test data collected in 2010 in
response to the EGU MACT ICR reflected compliance with the proposed standards during the 4-hour
steady state tests, but this source operator states that such steady state tests do not indicate if continuous
compliance is achievable at this source. Commenter 17623 states that the proposed limits for PM do not
allow for variability because they are based on the particular conditions during one stack test for CPM,
and the commenter believes that when setting a MACT standard, variability must be taken into account.
The commenter adds that since each stack test is time-consuming and costly, the EPA cannot expect
facilities to feasibly perform numerous stack tests.

Response to Comment 15: The final rule has removed the requirements for operating and fuel limits
with the exceptions noted in Response to Comments 10-14, above.

5. Comments related to concerns about use of Method 202.

Comment 16: Commenter 18014 states that despite Method 202 being revised to include a nitrogen
purge and an initial dry impinger (which is quickly wetted with condensation from the flue gas) to
reduce these artifacts, the remaining S02-related artifacts can be significant at low levels. According to
the commenter, because of the bias, extending the run time does not necessarily improve the accuracy or
detection limit since it simply provides more time for the artifacts to form and, thus, tends to defeat the
purpose of adding the purge/dry impinger. According to the commenter, recent studies have shown the
S02-related artifact formation to be particularly acute if there is any NH3 in the flue gas (e.g., slip from
an SCR for NOx control), which again is not related to primary particulate and certainly not related to
metal HAP in any way.

Comment 17: Commenter 17402 expresses concerns that condensable PM reference Method 202 is
unproven and variable and should be improved, because the commenter has reviewed many reports on
Method 202 and OTM 28 and has carried out Method 202 testing programs. The commenter asserts that
even with the recent improvements to Method 202 there are concerns about condensable PM formation
and creation of pseudo particulates. The commenter references recently completed Method 202 stacks
tests on a number of units using the same coal, and observations that the condensable PM fraction
ranged from 7% to 75%. This commenter relays plans to install Trona FGD controls to reduce HC1 and
to further reduce condensable PM but expresses concerns that Method 202 may not properly quantify
actual reductions. Commenter 17402 also relays plans to commission nine SNCR systems and
associated concerns about ammonia slip reactions with dissolved SO2. Commenter 17402 encourages
the EPA to continue research & development (R&D) on refined test methods to measure condensable
PM, with the goal of achieving a more reliable standard in time for the initial MACT compliance date;
however, the commenter believes that given the benefits of reducing condensable PM, the EPA should
not let testing uncertainty prevent the implementation of the total PM standard. Commenter 17402 refers
to the EPRI CEMS Users Group in Chicago, IL on June 8, 2011 and a presentation given by Clean Air
Engineering ("CAE") entitled "Description of a Potential Pseudo CPM Formation Mechanism in New
EPA Method 202" for a CFB boiler equipped with an SNCR. The paper concluded that due to its high
affinity for water, free NH3 in the gas stream will be absorbed in the aqueous layer of the Method 202
impingers and will react with SCMo form either ammonium sulfate or bisulfate. According to

10


-------
commenter 17402, CAE recommended that ammonium sulfate or bisulfate formed in the Method 202
dry impingers should be considered an artifact and the commenter quoted CAE's suggestion that "the
EPA should acknowledge that significant positive biases related to the interaction of SO2-NH3-H2O can
occur in the new M202, and should also allow for quantification and correction" of this artifact using
procedures prescribed by CAE or the EPA should modify Method 202 to reduce or eliminate the bias.
Commenter 17402 states that subtracting the inorganic condensable PM from Method 202 and adding
the inorganic condensable PM from CTM-013 (controlled condensation) was one of the steps included
in the proposed procedure.

Comment 18: Commenters 17725 and 18498 state that using only filterable particulate (in conjunction
with SO2 or HC1 for selenium) as a surrogate for non-Hg metals from coal combustion would avoid
various problems associated with including condensable particulate as part of the standard. According to
the commenters one of the fundamental problems with using Method 202 for condensable PM
measurements is that the results are overwhelmingly driven by sulfate and nitrate compounds, which
have nothing to do with metal HAP emissions. According to the commenters, Method 202 is also
problematic because of its high bias tendencies; the method is intended to provide a measure of
condensable "primary particulate," which is not PM at stack conditions but which condenses upon
cooling and dilution in the ambient air to form PM, as opposed to "secondary particulate," which forms
later as different compounds react and combine in the atmosphere over time. The commenters
acknowledge that one might argue over the merits of requiring sources to include condensable PM as
part of a measure to control ambient particulate/haze but assert that Method 202 is prone to biases due to
SO2 artifact formation (again, something that has nothing to do with metal HAP) that make the results
especially unreliable in conjunction with the long run times proposed under this rule. According to the
commenters, while Method 202 was revised to include a nitrogen purge and an initial dry impinger
(which is quickly wetted with condensation from the flue gas) to reduce these artifacts, the remaining
SO2 related artifacts can be significant at low levels. Also, according to the commenters, because of the
bias, extending the run time does not necessarily improve the accuracy or detection limit since it simply
provides more time for the artifacts to form and, thus, tends to defeat the purpose of adding the
purge/dry impinger. The commenters state that recent studies have shown the SCVrelated artifact
formation to be particularly acute if there is any NH3 in the flue gas (e.g., slip from an SCR for NOx
control), which again is not related to primary particulate and certainly not related to metal HAP in any
way and cite Bionda, J. and Evans, S., Description of a Potential Pseudo CPM Formation Mechanism in
New EPA Method 202, 2011 EPRI CEM Users Group Conference, Chicago, Illinois (June 8-10, 2011).

Comment 19: Commenter 17821 states that although the revisions of Method 202 finalized in 2010
have been demonstrated in the laboratory to reduce sulfate and other artifact formation, the EPA's data
show that it does not completely eliminate the high bias associated with the test method: "EPA reported
experimental results that showed the dry impinger modification to Method 202 reduced sulfur dioxide
artifact formation by more than 90%." See Method 202 Assessment and Evaluation for Bias and Other
Uses Evaluation of Stakeholder Recommendations August 4, 2006 through April 17, 2007.

Comment 20: Commenters 18935 and 18034 note that the new version of Method 202 published in
December 2010 is substantially different from Method OTM 28, which was used to generate ICR data.
The commenters express concern that the proposed rules have been developed from a dataset derived
from slightly different methodology than that which will be used to demonstrate compliance with the
proposed rules. Given the different train configurations and operating temperatures, the commenters
suspect that OTM 28 data are not directly comparable to Method 202 and therefore sources may have
difficulty planning or demonstrating compliance without substantial comparative testing.

11


-------
Comment 21: Commenter 17820 states that Method 202, recently finalized by the EPA to measure
condensables, is still prone to biases due to S02 artifact formation that has nothing to do with metal
HAP and makes resulting PM measurements questionable.

Response to Comments 16-21: The final rule does not require the measurement of condensable PM as
a part of an alternate equivalent standard for non-Hg metals, so we need not address these comments.

6. Comments related to frequency of stack testing.

Comment 22: Commenter 17775 states that the EPA must clarify the Hg testing requirements. The
commenter states that in the preamble, the EPA states that additional performance tests for Hg are
conducted "at least annually." (Proposal Preamble, 76 FR 25,029/3). The commenter agrees that Hg
testing should not be required any more frequently than annually. However, according to the
commenter, there is no reference to this annual testing in the proposed rule. Instead, according to the
commenter, the rule requires testing either monthly, or every other month, for "individual or total HAP
metals" and cites Proposal section 63.0006(f) and (g). The commenter states that the agency should
revise its proposal to reduce all stack testing to no more frequently than annual. According to the
commenter, there is no reason to require Hg testing in addition to "individual or total HAP metals"
testing.

Response to Comment 22: In the final rule, annual Hg testing is required as part of demonstrating the
continued applicability of the LEE provisions for a unit that qualifies as an LEE for Hg. For units with
Hg CEMS or sorbent trap monitoring systems, Hg performance tests are not required on an annual basis,
although the monitoring systems will be subject to ongoing QA, including RATA tests.

Comment 23: Several commenters (17730, 17775, 17808) express concerns about the number of stack
tests required under the proposal's stack testing compliance options. Commenter 17808 expresses
concerns about the monthly or bi-monthly stack testing requirements in the proposed rule for units not
measuring emissions continuously. For example, the commenter notes, liquid oil-fired EGUs would be
required to test for all HAP metals on a monthly basis if they do not have a PM control device installed,
or once every two months if they do have a PM control device. Additionally, the commenter notes, they
would need to test for HC1 and HF on a monthly basis because there are no controls currently installed
for addressing these pollutants at oil-fired EGUs. According to the commenter, coal-fired EGUs would
face similar obligations. Commenter 17808 believes that the proposed frequency of testing will place a
significant cost burden on plant operators. According to the commenter, stack testing can also be unsafe
for testing personnel during harsh weather conditions, particularly the cold winter months. Finally,
according to the commenter, inflexible testing schedules may induce units to run solely for testing
purposes, leading to increased emissions. In addition to company costs and staff time, the commenter
notes that state-level environmental regulators may need to be on site to witness the tests and expresses
concerns that the large number of units affected by the rule and the proposed testing frequency could
make staff availability a significant issue. The commenter is also concerned that this could result in
delayed compliance testing or not being able to dispatch a unit (that has not been able to schedule
required compliance tests). In an effort to balance these concerns with the need for reliable compliance
demonstrations, the commenter recommends that all stack testing requirements be no more frequent than
quarterly under standard operation (i.e., unless boiler operations or characteristics are substantially
altered, in which case initial testing should be repeated). The commenter believes that quarterly stack
testing in combination with parameter monitoring should be enough to ensure that a unit is operating
within the required limits because quarterly testing would capture seasonal variations in operation while
not unnecessarily repeating tests at the same conditions. Commenter 17730 characterizes the proposed

12


-------
monitoring option for sources not using CEMS as excessive and overly burdensome because the
commenter believes the requirement to conduct stack testing either monthly or bi-monthly is a very
expensive and time consuming operation, especially when testing at the very low levels necessary to
comply with the proposed MACT standards. The commenter states that the sampling times that will be
necessary to collect enough sample volume to record values over the method detection limits will
require extended hours of testing operations, and the extended hours of testing further increase
compliance costs. Commenter 17730 believes that compliance with monthly stack testing requirements
will put sources in a nearly continuous mode of stack testing. The commenter recommends that the
agency consider requiring stack testing on an annual basis combined with an appropriate level of
parametric monitoring and defined operating limits because such requirements are adequate to ensure
compliance and to protect public health and the environment. Commenter 17775 also expresses concerns
with the proposal's stack testing options for HAP metals with respect to the frequency of repeated stack
tests and states that the EPA has provided no rationale or data for the proposed frequency of stack
testing or accounted for the cost of such frequent testing in its proposed ICR. The commenter references
the EPA's supporting statement for the February 2011 proposed ICR describing the existing source
requirement as testing with Method 29 initially and every 2 years thereafter. [EPA-HQ-OAR-2009-
0234-3031 at Tables la, lb, lc.] However, the commenter interprets the statement as assuming that no
source will perform anything other than initial testing. The commenter states that the proposed
frequency of testing is by definition arbitrary and capricious and contends that EGUs demonstrating
initial compliance through stack testing and confirming compliance by monitoring and responding to
appropriate operating parameters should not need to conduct additional stack tests more frequently than
annually, unless the EGU's fuel type or controls change. The commenter contends that such frequent
testing adds nothing but cost and states that the agency points to no other variables to justify such
frequent testing. The commenter acknowledges that the proposal allows some provisions for reduced
testing, but counters that the 50 percent criteria for qualify for these provisions makes them too
restrictive to be useful.

Comment 24: Comment 18498 states that the frequency of the additional performance testing
requirements is not consistent with the expected variability in stack emissions. Units without add-on
control systems are required to complete stack tests less frequently than units with add-on control
systems. According to the commenter, for units without add-on control systems, the emissions of HC1,
HF, and non-Hg metals are most closely tied to fuel characteristics. In lieu of requiring more frequent
performance tests if a source chooses to use the alternate standards for certain subcategories, the
commenter recommends periodic fuel analysis to determine if a significant change has occurred since
the previous performance test. According to the commenter, if there is a significant change of fuel HAP
concentrations then additional emissions testing might be warranted but the source's expected removal
efficiency should also be taken into consideration to minimize unnecessary testing. The commenter
believes that annual performance testing is sufficient to demonstrate proper operation of control devices
and has historically been sufficient.

Comment 25: Commenter 18498 states that because many liquid oil-fired sources operate infrequently
and only during peak demand periods for liquid oil-fired sources, the proposed testing magnifies the
burden of frequent testing. The commenter notes in the preamble the EPA found that for liquid oil-fired
units, no correlation was found between non-Hg metallic HAP emissions and PM emissions or the
operation of PM control devices. As such, according to the commenter, the emissions of HC1, HF, and
non-Hg metals are most closely tied to fuel characteristics and thus it would be more meaningful to
assess fuel characteristics and use that information to determine whether additional emission testing is
needed.

13


-------
Comment 26: Commenter 18025 states that they support the proposal to allow existing sources the
option to comply with input- or output-based standards, and recommend that the EPA maintain this
flexibility in the final rule. However, the commenter believes that the proposed compliance
demonstrations are unnecessarily frequent, and recommend quarterly testing for all HAP. According to
the commenter, quarterly testing provides the necessary performance guarantee, while balancing the
substantial costs of stack testing.

Response to Comments 23 - 26: In response to comments, the final rule has been amended to include
quarterly periodic testing and retains the option to comply with input-or output based standards for
existing units. For liquid oil-fired units that use the quarterly performance test option, the source will
also need to develop a site-specific monitoring plan to ensure that operations between tests remain
consistent with the operations during the performance test. Please see the final preamble for further
discussion.

Comment 27: Commenter 17880 supports the requiring of coal-fired, IGCC and solid oil-derived fuel-
fired units to conduct HAP metals and PM testing at least every 5 years, using the current process
outlined by EPA Methods 29, 5, and 202. Additionally, the commenter states, units that have elected to
comply with the HAP metals emission limits instead of total PM emissions limits would be required to
conduct total or individual HAP emissions testing every 2 months to demonstrate continuous
compliance.

Comment 28: Commenter 17191 states that for IGCC units, the proposed rule requires either use of PM
CEMS or Method 29 stack testing and that Method 29 is required every 2 months if PM controls are
installed or every month if no PM controls are installed. The commenter requests that this requirement
be clarified to indicate that the "PM controls" can be pre-combustion controls such as the gasification
process for IGCC units because traditional post-combustion PM controls are not used in IGCC systems.
Commenter 17191 states that PM is captured "upstream" of the combustion turbine in the gasification
phase and that such a design configuration should not be used to require monthly stack testing under the
Method 29 compliance option.

Response to Comments 27 - 28: In the final rule, if a PM CPMS is used, the source must reestablish the
operating limit by conducting a test every year, not on a 5-year basis. This approach recognizes that the
operating limit associated with the PM CPMS is a surrogate operational requirement that does not
provide the same degree of assurance as a direct measurement of the emissions limit, and needs to be re-
established over time. With respect to the frequency of tests where continuous monitoring is not used to
demonstrate compliance, the final rule does not distinguish between units with or without controls, so
the concerns on how to classify IGCC combustion controls are inapplicable.

7. Comments related to derating units.

a. Compliance Plans to temporarily derate units while air pollution control upgrades are
completed.

Comment 29: Commenter 17402 states that the EPA should clarify that stack testing may be performed
at loads where facilities can meet all emissions and operating parameters because some upgrades
required to meet certain MACT standards may not be fully operational as of the compliance deadline,
and the commenter believes that compliance prior to completion of air pollution control upgrade projects
can only be achieved by operating such units at reduced load. Commenter 17402 requests that the EPA
clarify that "maximum normal operating load" under the proposed performance test guidelines can

14


-------
include short-term, full-load operating restrictions if such generating load restrictions are necessary to
ensure compliance in advance of completion of air pollution control upgrades. Commenter 17402 notes
that in proposed section 63.10007(c), the EPA specifically allows for the conducting of tests at
"differing operating limits," implying that the EPA expects the operating load to be somewhat flexible,
and the commenter states that the EPA should not require operations during a performance test which
the operator knows will cause a violation. Instead, the commenter requests that the final rule allow
operators to choose an interim compliance operating level for up to 3 years so that the operating limits
set based on the most recent performance test well temporarily limit maximum capacity to 110% of the
operating load achieved during the most recent performance test.

Commenter 17402 additionally requests provisions in the final rule that would allow facilities that
choose to restrict load (while air pollution control upgrades are installed) to resume operations at the
pre-MACT, full-load capacity upon demonstrating compliance at the true maximum capacity during a
periodic performance test. The commenter notes that the EPA has supported interim control strategies
previously, including voluntary capacity reductions.

Response to Comment 29: The EPA believes the proposed and final rules already provide for this type
of flexibility. If a source adopts a derate restriction as a condition of its federally enforceable operating
permit for a source, then testing at full load for that source would be conducted in accordance with the
terms of the permit as to what full load means. As part of modifying the permit to lift the restriction, the
EPA would anticipate that testing to demonstrate compliance with this rule would be part of the action
that a source would need to take in order to demonstrate compliance.

b. NSR implications of interim MACT compliance strategies involving derates.

Comment 30: Commenter 17402 requests, regarding temporary measures to administratively derate a
unit to a generating capacity that can comply with MACT standards while air pollution control upgrades
are installed, that the EPA provide clarification on the implications of such a compliance strategy under
the NSR program. The commenter believes that once the emissions controls are installed and fully
operational and the facility ends the voluntary capacity reduction, prevention of significant deterioration
(PSD) or NSR should not be triggered provided that there is no significant increase in emissions from 2
consecutive calendar years of operations prior to the interim control strategy's implementation.
According to the commenter, since "baseline actual emissions" are defined as any consecutive 24-month
period from the 5 years prior to the start of construction, an operator could reasonably choose 24 months
from the period preceding the interim control strategy's voluntary capacity reduction, provided that
construction started within 3 years of the interim control strategy implementation. The commenter states
that "increase" is defined as the difference between baseline and potential annual emissions, where
potential is the maximum projected emissions in any of the next 5 years. As a result, according to the
commenter, with a properly designed control upgrade, a facility's operating capacity before and after the
interim control period would be identical, and the emissions in question would decrease. Given the clear
emissions reductions, and conformity with existing regulations, the commenter requests that the final
rule confirm that the use of an interim control strategy of voluntary capacity reductions will not result in
triggering NSR or PSD requirements.

Response to Comment 30: PSD permit implications of the derate strategy mentioned by the commenter
would be addressed in accordance with the implementing regulations and accompanying guidance for
the NSR program as in effect at the time of such compliance approach taken by the source. Those
implications are not part of this rulemaking, and the EPA will respond to specific questions and requests

15


-------
for guidance on a case-specific basis under the normal procedures established for issuing guidance and
policy interpretations under the NSR program.

8.	Comment related to bypass requirements - CEMS.

Comment 31: Commenter 17675 states that the requirement in section 63.10010(a)(4) for installing,
operating, and maintaining a complete CEMS system on a bypass stack is not appropriate for EGUs that
only use the bypass stack for a short time during startups and shutdowns because such a requirement is
excessive, unnecessary, and difficult to maintain in a state of readiness for a few hours of usage on an
occasional basis. The commenter believes that alternative monitoring methods such as data substitution
techniques similar to those used in 40 CFR part 75 or fuel sampling for Hg during startups and
shutdowns must be allowed rather than requiring installation of a duplicate and seldom utilized CEMS
system for a startup bypass stack.

Response to Comment 31: The EPA has modified the bypass stack monitoring requirements. Under 40
CFR Part 75, the EPA allows the use of a maximum potential concentration value on a bypass stack.
That approach works within the broad context of an emissions trading program but does not work when
evaluating compliance with a specific emission limit over a shorter period. Thus, the final rule provides
two other options for a source. One is to monitor the bypass stack consistent with the proposed rule. The
other is to treat any hours of bypass stack emissions as periods of monitor downtime. In general, this is
consistent with the EPA's approach to startup and shutdown periods, in that we treat those periods as
subject to a work practice standard. That generally obviates the need to monitor the bypass stack as the
emission limit does not apply during the periods when the source is most likely to operate a bypass
stack. Use of a bypass stack at times when the source is operating and the emission limit applies (i.e.,
other than startup or shutdown periods), will mean a failure to monitor emissions at all times in
accordance with the rule.

9.	Comments related to duplicative testing.

Comment 32: Several commenters (17820, 17868, 18014) state that the EPA is requiring stack tests for
both the pollutant and surrogate and that this requirement is superfluous. The commenters state that the
EPA has established alternative limits for compliance for various HAP groups. For example, state the
commenters, coal-fired units may choose to meet either the PM limit, the limits for individual metals, or
a total non-Hg metals limit to establish compliance for metal HAP and may monitor S02 or HC1 for acid
gas HAP, and these options provide the sources with a measure of flexibility. According to one
commenter, since limits for each pollutant (or surrogate) have been independently established to assure
effective reductions in accordance with section 112 of the CAA, there is no need to test for both the
pollutant and surrogate. The commenters indicate that a performance test should only be required for the
pollutants and surrogates with which the source is choosing to show compliance.

Comment 33: Commenter 17775 believes that the EPA's proposed compliance demonstration,
recordkeeping, and reporting requirements are flawed because the applicability of many provisions is
unclear and the EPA fails to provide any rationale by which the provisions' basis and purpose might be
discovered. The commenter states that for the first time in any MACT, and without explanation, the
EPA proposes to require that EGUs exercising the option to comply with a surrogate emission limit also
stack test for the corresponding HAP, and conversely, that EGUs opting to comply with a HAP limit
stack test for the corresponding surrogate. According to the commenter, these duplicative testing
requirements are inconsistent with the agency's legal and policy justifications for the use of surrogates
and are otherwise unsupportable. The commenter states that for EGUs that opt to comply with a chosen

16


-------
emission limit using stack testing, the EPA (again without explanation) requires stack testing no less
frequently than every other month, requires compliance with established "operating limits" on control
devices, and requires compliance with fuel input limits. According to the commenter, the agency
provides no rationale for the selected frequency of stack testing and fails to include the associated cost in
its proposed ICR. According to the commenter, the requirements are unnecessary and inconsistent with
the EPA's prior position on use of surrogates, numerous preamble statements claiming cost savings by
use of surrogates, and the proposal to allow EGUs to choose whether to comply with a HAP limit or,
where surrogates are proposed, the surrogate limit. The commenter states that where the EPA has
demonstrated the appropriateness of use of a surrogate and selected an emission limit for that surrogate
that is consistent with what the best sources achieve, there is no basis for also requiring the source to test
for the applicable HAP. According to the commenter, the EPA says as much in the preamble, and the
commenter cites portions of the preamble (including the following portions and language: the agency
summarizes the D.C. Circuit decision in National Lime Ass'//, 233 F.3d 625: If these criteria are satisfied
and the PM emission standards reflect what the best sources achieve — complying with CAA section
7412(d)(3) —" EPA is under no obligation to achieve a particular numerical reduction in HAP metal
emissions." We have considered this case in evaluating whether the surrogate standards we propose to
establish in this proposed rule are reasonable. 76 FR 25,021/3. The EPA has satisfied the criteria for use
of PM, HC1, and S02 as surrogates. See 76 FR 25,039/3, 25,040/1, 25,041/1.). According to the
commenter, the same is true with respect to testing for surrogates. The commenter states that where the
EPA has established an emission limit for a HAP that is consistent with what the best sources achieve,
there is no basis for also requiring testing of a surrogate. Commenter further notes that in National Lime
Ass'//, the EPA's position with respect to use of PM as a surrogate was that it '"achieves exactly the
same level of HAP metal emissions limitations' as would be reached were the metals to be regulated
directly," and that the "use of a surrogate 'eliminates the cost of performance testing to comply with
numerous standards for individual metals" (citing F.3d at 637 (quoting 64 FR 31,916/3)). According to
the commenter, the Court found the EPA's use of the surrogate reasonable (citing id. at 639). If the HAP
limit and the surrogate limit provide equivalent control, the commenter asserts, there is no reason to test
for both, at any frequency, and the EPA has not suggested any purpose. The EPA also has not required
such duplicative testing in any other rule that relies on surrogates.

Commenter 1775 also asserts that requiring testing for both the HAP and surrogate is inconsistent with
Tables 1 and 2, which, according to the commenter, establish surrogate emission limits as "alternatives"
to HAP emission limits and vice versa. According to the commenter, requiring EGUs to test for HAP,
when they have opted not to meet the HAP limit, or requiring EGUs to test for a surrogate, when they
have not opted to meet a surrogate limit is completely unreasonable. The commenter states that the tests
have no regulatory purpose under the proposed rule and the EPA's preamble summary identifies none.
The commenter states that the EPA discussed the cost savings associated with using surrogates and
refers to 76 FR 25,038; at 25,039; at 25,059.

Commenter 17758 also disagrees with the proposal's requirement to test for surrogates at units using the
stack testing compliance option for non-Hg HAP metals and HC1, because according to the commenter,
if a utility has chosen to demonstrate ongoing compliance by directly measuring the regulated HAP, it is
superfluous to require any further testing of surrogates, and under the stack testing compliance option
the agency should specify that performance tests only for methods necessary to measure the regulated
HAP are required.

Comment 34: Commenters 17881 and 18428 state that where a surrogate is used the requirement to test
for the applicable HAP is duplicative and should be removed. For example, according to the
commenters, sources using PM as a surrogate for non-Hg HAP metals must perform metals testing in

17


-------
addition to stack testing for total PM and establishing a filterable PM limit and demonstrating
compliance with PM CEMS, and similarly, sources using S02 as a surrogate for HC1 must test for HC1
in addition to the SO2 CEMS performance test. Commenter 18428 notes that for EGUs that do not
choose to use a surrogate, the EPA proposes to require testing for surrogates anyway. For example,
notes the commenter, proposed section 63.10006(d) requires EGUs without PM CEMS, but with a PM
control device, to perform annual tests for both PM and non-Hg HAP metals. Similarly, proposed
section 63.10006(h) requires EGUs without SO2 CEMS to conduct "all applicable performance tests" for
S02 and HC1 annually and, for units with S02 controls, to conduct S02 emissions testing "at least every
other month." See also preamble, 76 FR 25,051. According to the commenter, where the EPA has
demonstrated the appropriateness of use of a surrogate and selected an emission limit for that surrogate
that is consistent with what the best sources achieve, there is no basis for also requiring the source to test
for the applicable HAP. The commenter asserts that where a source chooses to comply with the HAP
limit, testing for surrogates is unnecessary and unreasonable. The commenter also views both
requirements as inconsistent with Tables 1 and 2, which, according to the commenter, establish
surrogate emission limits as "alternatives" to HAP emission limits and vice versa. The commenter states
that although the EPA describes these duplicative testing requirements in the preamble, the EPA
provides no rationale to support them.

Comment 35: Commenter 18015 states that section 63.10000(c)(1) of the proposed rule provides that
for all coal-fired and solid oil-derived fuel-fired units the initial performance testing is required for all
pollutants. According to the commenter, this implies that for HC1, owners and operators would be
required to conduct performance tests for both HC1 and SO2, and for HAP metals, owners and operators
would be required to conduct performance tests for both PM and all individual HAP metals. According
to the commenter, this is inconsistent with the intent established in the preamble that facilities must
conduct performance tests to demonstrate compliance with all applicable emission limits. According to
the commenter, if a facility chooses to use PM as a surrogate pollutant and meet the PM limit set forth in
Table 1 or 2, then that becomes the applicable emission limit, and the HAP metals emission limits are no
longer applicable. The commenter asserts that this is supported by the fact that continuous compliance is
based on PM CEMS or other PM-related compliance mechanisms. Conducting the additional emission
tests for individual HAP increases the cost and labor time for no added benefit, according to the
commenter, because the facility will be complying with the PM emission limit, not the individual HAP
metals emission limits. Thus, states the commenter, initial compliance should only apply to the
applicable emission limit and result in testing of only the surrogate pollutant, PM, not HAP metals.

Comment 36: Commenter 18034 states that proposed section 63.10006 requires coal-fired and solid-oil
derived fuel-fired EGUs to perform testing for non-Hg metal HAP even if the source elects to use total
PM as a surrogate for the non-Hg metal HAP limits. The commenter states that similarly, the same
source categories are required to perform HC1 testing even if the source elects to use SO2 as a surrogate
for HC1. Furthermore, the commenter states, on-going compliance for units that are not equipped with
CEMS is through monthly or bi-monthly stack testing for pollutants that are the primary HAP when the
source is using a surrogate limit for the HAP. According to the commenter, the preamble (76 FR 25029)
states that the purpose of the stack testing is demonstrate compliance with all applicable emission limits;
however, if a coal-fired EGU is using the PM surrogate option, the unit is not subject to the non-Hg
metal HAP limits and a demonstration of compliance is not necessary. The same issue applies to an
EGU using S02 as a surrogate for HC1, the commenter states. According to the commenter, the EPA
provides no explanation for why the proposed rule requires sources to test for pollutants for which there
are no applicable emissions limits. The commenter also asserts that section 63.10006 is inconsistent with
the EPA statements in the preamble that use of the PM surrogate would eliminate costs associated with
conducting performance testing for non-Hg metals (76 FR 25039). According to the commenter, these

18


-------
additional testing requirements provide no added compliance assurance for the rule and unnecessarily
impose extensive burden on regulated sources as well as state agencies that are delegated enforcement
authority for the NESHAP and responsible for overseeing required stack testing. The commenter asserts
that if these overlapping testing provisions are inadvertent, then the EPA must revise the rule to clearly
indicate that sources are not required to test or monitor for HAP when a surrogate limit for those HAP
has been selected. However, states the commenter, if the EPA is intentionally requiring sources to test
for HC1 and non-Hg metal HAP even if the sources are using a surrogate limit and do not have to
demonstrate compliance with the specific HAP, then the EPA must provide a reasoned justification for
the additional testing and explain the intended purpose of the test results.

Comment 37: Commenter 17868 states that the EPA must remove the requirement for SO2 performance
testing. According to the commenter, proposed section 63.10006(h) and (i) include testing provisions for
SO2 for units without SO2 CEMS. According to the commenter, the EPA must make clear that these
provisions do not apply to EGUs complying through HC1 stack performance testing. The commenter
states that there is no basis for testing of the surrogate SO2 at a unit that is complying with the HC1
standard. In addition, according to the commenter, the proposed rule does not provide any procedure for
SO2 performance testing or an SO2 emissions standard other than those applicable to units with SO2
CEMS. The commenter states the EPA has no basis to require EGUs that choose to comply through
stack testing to also install an SO2 CEMS.

Response to Comments 32-37: In response to comments, the final rule has removed all requirements
for testing of both the individual HAP and the surrogate. Facilities complying with a surrogate limit do
not have to perform periodic testing for the corresponding HAP.

10. Comments related to non-Hg metal standards.

Comment 38: Commenter 17775 supports the proposed inclusion of an option for non-Hg HAP metals
stack testing (i.e., Method 29) but contends that the proposed rule contains duplicative testing
requirements under the non-Hg HAP metals stack testing option. The commenter believes that to make it
a reasonable option, the final rule must reflect several adjustments:

1.	First, the commenter believes the final rule must remove the requirement for annual PM testing
under section 63.10006(d) because no justification is provided for this requirement. Furthermore,
notes the commenter, proposed Tables 1 and 2 clearly provide sources the option of meeting either a
PM or non-Hg metals limit. Testing for PM when that option has not been selected and no limit
applies is nonsensical. The commenter concludes that requiring testing for a surrogate in addition to
the regulated HAP is beyond the agency's authority.

2.	The commenter believes that the EPA should re-evaluate the proposed operating parameter
requirements because the operating parameters specified for non-Hg metal controls are not
sufficiently connected to metals removal or sufficiently flexible to be used as enforceable limits. The
commenter contends that secondary power is not directly related to PM removal and that pressure
drop and liquid flow will vary with load. Moreover, according to the commenter, at the level of the
proposed standard, metals control may not be very sensitive to liquid flow. The commenter states
that the final rule must allow for adjustment of load-dependent operating parameters to account for
load changes, and the final rule should use the operating parameters as indicators, not enforceable
limits.

3.	The commenter states that the final rule should make clear that EGUs combusting a single fuel type
are not required to make any determination regarding that fuel under section 63.1001 l(b)(3)(i)
(requiring determination that the fuel type or mixture has the highest content of non-Hg HAP metals)

19


-------
and that EGUs using supplemental fuels qualify as single fuel EGUs. The commenter notes that
although the proposal attempts to address that issue for liquid oil-fired EGUs in section
63.10005(c)(4) and section 63.10011(c)(1), those provisions apply only to liquid oil-fired EGUs
complying through fuel analysis.

4. Commenters 17775 and 17868 state that the final rule should specify minimum detection limits for
laboratory analyses and provide procedures for calculating combined concentrations of single metals
and total non-Hg metals. According to Commenter 17775 the data collected in the 2010 ICR
indicated the reported detection limits for laboratory analyses were highly variable even for data for
the same metal and from the same laboratory. To determine compliance on a consistent basis, the
final rule must specify minimum detection limits and a procedure for combining front and back half
fractions to report total concentrations.

Response to Comment 38: We agree that maintaining low method detection levels is critical in
demonstrating compliance with the applicable emissions limits for this MACT rule. We disagree that we
can provide default values for method detection levels to use in determining compliance since there are
many site-specific factors that can affect method detection levels for any one set of data. In achieving
the most effective testing including method detection levels commensurate with compliance
determinations, the tester must consider multiple technical and procedural choices and analytical
laboratories used in any test program. There are some testing factors that we believe are appropriate for
the rule to address including minimum sample volume and some specific analytical finishes; however,
those required elements do not lead directly to maximum method detection levels. The EPA agrees
about the need for a procedure to combine the front and back half fraction and has revised the final rule
to address this concern. It is difficult to define maximum acceptable method detection levels that would
adequately account for the myriad of test matrices, interference, various types of analytical finishes, and
final analytical volumes that could very well be effective for all situations. Instead, the rule includes a
requirement that specifies how to use method detection level information in calculating compliance with
the emissions limits. The language in the final rule is similar to that found in the Mercury cell Chlor-
alkali plant regulations (see § 63.8232(c)(1)). The source must use the test specific method detection
level in calculating compliance with an emissions limit for any value measured and reported as below
detection level.

On the other issue of method detection capabilities for fuel sampling and analyses, the removal of the
proposed fuel input operating requirements in the final rule renders the concerns about identifying
highest fuel mixture and supplemental fuels no longer relevant.

11. Comments related to HC1 standard testing.

Comment 39: Commenter 17775 expresses the following concerns with the HC1 stack testing option:

1.	The commenter supports the proposed inclusion of an option for HC1 stack testing. However, the
commenter contends that to make it a reasonable option, the final rule must include several
adjustments. First, the commenter states, the EPA must remove the entire requirement for S02
performance testing under this option because there is no basis for testing of the surrogate SO2 at a
unit that is complying with the HC1 standard. In addition, the commenter states, the proposed rule
does not provide any procedure for SO2 performance testing, or an SO2 emissions standard other than
those applicable to units with S02 CEMS. The commenter states that the EPA has no basis to require
EGUs that choose to comply through stack testing to also install an SO2 CEMS.

2.	Second, according to the commenter, the EPA should re-evaluate the proposed operating parameter
requirements because the operating parameters specified for HC1 are not sufficiently connected to

20


-------
HC1 removal or sufficiently flexible for use as enforceable limits. The commenter states that the
EPA also must allow for adjustment of load-dependent operating parameters to account for load
changes and should use the operating parameters as indicators not enforceable limits.

3.	Third, according to the commenter, the EPA should make clear that EGUs combusting a single fuel
type are not required to make any determination regarding that fuel under section 63.1001 l(b)(l)(i)
(requiring determination that the fuel type or mixture has the highest chlorine content) and that
EGUs using supplemental fuels qualify as a single fuel EGUs. The commenter states that although
the agency has attempted to address that issue for liquid oil-fired EGUs in section 63.10005(c)(4)
and section 63.10011(c)(1), those provisions apply only to liquid oil-fired EGUs complying through
fuel analysis.

4.	Fourth, the commenter re-iterates previously stated concerns about the frequency of stack testing
required under the stack testing compliance option but relates the concerns to the HC1 standard
rather than HAP metals standard.

Response to Comment 39: The final rule has been amended to remove the requirement for testing of
both SO2 and HC1. Operational parameter requirements specified for HC1 have been removed. The
frequency of periodic testing has been reduced to quarterly testing. With the removal of the proposed
fuel input operating requirements in the final rule, the concerns about identifying highest fuel mixture
and supplemental fuels are no longer applicable.

Comment 40: Commenter 17807 states that preliminary HCI testing using Method 320 (FTIR) and
Method 26 generally show a considerable disparity in the reported concentration of HCI. According to
the commenter, Method 26A is reported to be approximately 5 to 10 times higher than Method 320. The
discrepancy is considered significant despite sampling on different dates and taking into account
variances in chemical composition of coal. According to the commenter, this data supports the high
biases of chlorides from FGD systems running with high equilibrium chloride concentrations.
Furthermore, asserts the commenter, the test results imply Method 26A may not be an appropriate test
method for testing HCI emissions in wet stacks. The commenter suggests the EPA evaluate these
discrepancies in wet stacks using Method 320. (See 17807-Al_Table_2_&_3.doc.)

Response to Comment 40: The EPA has amended the final rule to include the option for periodic HCI
testing by Method 320.

Comment 41: Commenter 17696 states that coal-fired EGUs without an HCI CEMS should be allowed
to reduce the frequency of HCI stack testing or fuel analysis if the EGU's initial performance test is less
than 50% of the standard. According to the commenter, for coal-fired EGUs that do not install an HCI
CEMS, proposed section 63.10006(k) and (1) require performance testing either monthly (for EGUs
without an FGD) or every other month (for EGUs with an FGD). Commenter 17696 contends that for
EGUs whose initial emissions stack test is less than 50% of the applicable HCI emission limit, monthly
or bi-monthly performance testing for HCI is excessive, unnecessary and unduly burdensome.
According to the commenter, EGUs that emit at such low HCI emission levels are able to do so as a
result of the chlorine content inherent in their fuel. As long as there is no change in fuel, the commenter
asserts, there is no expected change in the level of HCI emissions. The commenter suggests that an
alternative approach for sources testing at less than 50% of the standard is to require subsequent
performance tests less frequently, such as semiannually. Commenter 17696 also states that a 50%
threshold would be consistent with the threshold for reduced frequency of monitoring in proposed
section 63.10006(o) and states that operating parameters and fuel analysis demonstrating no material
changes in the fuel supply are sufficient to assure compliance with the applicable HCI emission limit
between semi-annual performance tests.

21


-------
Response to Comment 41: The final rule has been amended to require quarterly HC1 testing for sources
not using an HC1/HF or S02 CEMS option. The EPA disagrees that one performance test at 50% of the
emission standard would be adequate to ensure compliance. However, the final rule adopts a LEE
provision for pollutants other than Hg that enables a source to move to annual testing if all tests for the
applicable pollutant over a 3-year period are less than 50% of the emission limit.

Comment 42: Commenter 17754 requests that the EPA revise the compliance demonstration
requirements applicable to EGUs achieving LEE status for Hg, and the commenter contends that the
final rule should provide an additional compliance option for LEEs with Hg emissions below 50% of the
applicable LEE threshold; according to the commenter, such very low emitting EGUs should be allowed
to demonstrate continuous compliance through annual stack testing and should not be required to
conduct monthly fuel analyses.

Response to Comment 42: The LEE threshold for Hg remains at the 10% threshold that the EPA
proposed (or the total mass limit of <29 pounds per year, as requested by another commenter for
consistency with existing state rules). However, there is no monthly fuel analysis requirement for units
that qualify, but rather an annual test, consistent with the commenter's recommendation.

12. Comments about concerns with combined stack.

Comment 43: Commenter 18932 states that the use of combined stacks will undermine monitoring and
enforceability because the stringency and practicable enforceability of an emission standard depends
largely on the precision of its associated monitoring regimen. The commenter asserts that monitoring
requirements that do not reflect appropriate averaging times based on applicable emissions or air quality
standards do not assure continuous compliance with those standards. Similarly, the commenter states, to
assure that each EGU meets all applicable MACT emission standards, the Utility Air Toxics Rule must
specify monitoring requirements that will accurately measure and record the HAP emissions from each
individual source. The commenter does not believe that the proposed rule will accurately measure and
record emissions from individual sources and believes that the agency must clarify monitoring
requirements in cases where multiple individual units co-located at a single facility exhaust through a
combined stack. According to the commenter, this problem arises in two ways: (1) when multiple
emission sources vent gases through separate flues that are physically located within the same stack; and
(2) when multiple emission sources vent commingled exhaust gases through a common stack.

The commenter asserts that, first, there are many cases where multiple individual units exhaust through
individual flues that are co-located within a combined stack. According to the commenter, the rule
should make it clear that, in such cases, individual flues should be monitored separately, since there is
no impediment to doing so. According to the commenter, the combined stack, in these instances, is
simply the structural unit that encloses the flues, which are the separate, functional, exhaust gas emission
points.

The commenter also asserts that there are many other instances where the exhaust gases generated by
individual EGUs enter, commingle, and exhaust through a common stack. According to the commenter,
to assure that each EGU that vents through a combined stack complies with applicable MACT standards,
the EPA should require separate monitoring and reporting of each unit's HAP and surrogate emissions
prior to the exhaust gases commingling in the stack, such as prior to the stack breeching. According to
the commenter, a monitoring regime that does not require each source to separately monitor and report
its HAP emissions will not assure that each covered EGU complies with all applicable MACT

22


-------
requirements. The commenter provides an example of monitoring emissions at both types of combined
stacks.

Response to Comment 43: A common stack with individual flues (and no commingling of emissions
from the individual units) will require monitoring and testing on each separate gas stream. Each flue
would be the monitored or tested location at any unit that operates in such a manner. For the more
typical common stack situation in which emissions from multiple units may be released through a single
combined stack, the rule allows for either separate monitoring at the unit level or monitoring of the
combined emissions. In the latter case, any failure to meet the standard at the combined location would
be deemed a separate compliance issue for each individual unit to which the standard applies.

13.	Comments about using total PM.

Comment 44: Commenter 17621 states that the use of total PM as a surrogate parameter for HAP
metals is problematic due to shortcomings in the test methods for the two components of PM (filterable
and condensable PM). According to the commenter, particulate monitors measure only the filterable
portion of total PM, and the manual stack test methods for both filterable and condensable PM are of
uncertain accuracy.

Commenter 17621 also states that the EPA's rationale for including condensable PM in the MACT limit
to represent selenium is not supported.

Comment 45: Commenter 17877 states that the proposed total PM MACT is unworkable for several
reasons. According to the commenter, while Method 5 is more accurate in the short run, it does not (and
cannot) account for variations in filterable PM actual levels over a range of unit operating levels as
would a less accurate PM CEMS. Optical, light scatter, and light extinction PM CEMS are not accurate
enough to acquire meaningful values for developing a PM limit, but they could be used to determine
variability. According to the commenter, Laser Beta Gauge or Tapered Element Oscillating
MicroBalance (TEOM) PM samplers are much more expensive, but could be used to develop a body of
data that is both accurate and inclusive of operating variability over long periods. The commenter is not
aware that any such data was used to inform the development of the PM standard, but contends that this
analysis should be performed on the 12% of existing units identified in the development of the PM
surrogate for HAP metals.

Response to Comments 44 - 45: As discussed in detail in other sections of this document (see 4F01
responses), the requirement for total PM testing has been removed from the final rule.

14.	Miscellaneous comments regarding testing.

Comment 46: Commenters 17621 and 17758 state there is a need to establish test methods that can
measure the HAP or surrogates accurately at the actual stack gas concentrations. Commenter 17621
refers to an EPRI study that evaluated whether an accurate measurement could be obtained by most of
the ICR laboratories at those emission levels using the standard methods required by the ICR (Appendix
B; Method Sensitivity for ICR Data Usage and Compliance with Proposed MACT Limits). The
commenter concludes that the method sensitivity is not adequate to quantify HAP or surrogates at many
of the new unit limits that EPA is proposing. According to the commenter, the reason for this is that the
EPA's floor procedure relied on outliers and did does not take into account method performance with
actual stack gas samples.

23


-------
Comment 47: Commenter 17725 states that in section 63.7520(d), the EPA minimum sampling time of
4 hours for each test method seems excessive for certain pollutants. The commenter recommends that
the EPA re-evaluate the required sampling times for each method and/or provide alternative minimum
sample volumes for each method, taking into account representative analytical detection limits and
emissions standards that are properly adjusted for non-detect values.

Response to Comments 46-47: The EPA reviewed the minimum sample volumes required for the
emissions limits and, based upon the present analytical capabilities, concluded that the sample volumes
specified are appropriate. In the future, facilities with the capabilities to meet the stack detection limits
in less than required volumes may request alternative test methods per 63.8(f).

Comment 48: Commenter 17731 states that the proposal to require "total PM and HAP metals testing
during the same compliance test period and under the same process (e.g., fuel) and control device
operating conditions at least once every 5 years" (citing 76 FR 25029/2), has not been justified given
that it is highly unlikely an EGU could demonstrate compliance with the total PM limit while exceeding
the individual PM and HAP metals limits.

Response to Comment 48: The final rule will not require testing of both the filterable PM emission
limit and the corresponding HAP metals standard. The source will conduct the test that is applicable to
the standard with which the source has elected to comply.

Comment 49: Commenter 19033 states that the Table 8 data recording requirements should match the
sampling times specified in Table 7. The commenter states that for example, scrubber and ESP
parametric data is mandated by Table 7 to be recorded at 15 minute intervals during each test run. Three
test runs are then required. According to the commenter, since Table 8 requires that subsequent data is to
be maintained in 12-hour block averages, it would seem the EPA wants each test run to last 4 hours.
However, the commenter states, as examples, Table 2 specifies that each PM test run needs to collect a
minimum of 2 dscm, and each HCI test run using Method 26A needs to collect a minimum of 0.75
dscm. The commenter doubts that it will take 4 hours to meet the minimum test run sample volume for
either pollutant and therefore they recommend that Table 8 be amended from 12 hours to the time period
required to perform three test runs.

Response to Comment 49: For the 12-hour block average limits discussed in this comment, the EPA
notes that the final rule does not require data reporting of these parametric data. Generally, the only
operating data reported under the final rule are PM CPMS data (see the final preamble and other
responses pertaining to the potential for liquid oil-fired units to require operating parameter data in
certain situations). The source will collect hourly data during the performance test, identify the highest
hourly average during the test, and then record data during operations on an hourly basis and develop a
rolling 30-day average of the PM CPMS data. There is no intent that the 30-day average represent the
length of the Method 5 or 29 stack test.

Comment 50: Commenter 18963 states that if the EPA does not agree to revise the proposed rule to
provide that if an owner/operator of an affected EGU elects to demonstrate compliance with total non-
Hg HAP metals by using the PM surrogate, then such owner/operator is not required to conduct
performance tests for PM and total non-Hg HAP simultaneously, the proposed rule must nonetheless be
revised to avoid additional ambiguities. Specifically, according to the commenter, the proposed rule
lacks clarity related to the requirement to conduct periodic emissions testing for HAP metals and total
PM during the same compliance period and under the same process and control device operating
conditions (citing76 FR 25,106). According to the commenter, the proposed rule fails to clearly address

24


-------
a facility's compliance status if it simultaneously conducts stack testing for HAP metals and PM during
the same compliance period, and demonstrates compliance with the applicable standards for one of these
two pollutants.

Response to Comment 50: The final rule has been amended to remove the requirement for testing total
non-Hg HAP metals if the source elects to meet the filterable PM standard (and vice versa).

Comment 51: Commenter 18021 states that any performance testing of an EGU needs to be
representative of the unit's actual operation. According to the commenter, EGUs ramp up and ramp
down based on demand, and the performance testing needs to be based on a test plan that will, in the
end, reflect the unit's actual operation. According to the commenter, that unit's specific test plan needs
to make it possible to "certify" and have the documentation demonstrating that the EGU configuration,
control devices, and material/fuel have remained constant since the prior performance test was
conducted (section 63.10005(d)(l)(iii)). According to the commenter, this protocol would be consistent
with section 63.1 0007(c). The commenter asserts that the flexibility to address normal operating
conditions should be clearer. The commenter provides that if an affected unit chooses to establish limits
for PM as a surrogate for metals and if the limit on PM were established based on a one-time test of
three runs at maximum potential operating load, the affected source would be penalized at those units
where over-controls were provided to allow for a compliance buffer.

Comment 52: Commenter 18015 opposes the proposed requirement for periodic compliance testing for
several individual HAP for which the proposed rule designated a single surrogate. The commenter
believes that demonstration of continuous compliance for that surrogate based on data collected with
CEMS should assure compliance with the requirements for the individual HAP that surrogate represents.

Response to Comments 51 and 52: The agency agrees with the commenter that performance testing
should be representative of an EGU's actual operation. For initial short term performance tests (e.g.,
manual three run tests), the rule specifies that emissions testing is to occur at maximum normal
operating loads. The rule also reminds EGU owners or operators of the ability to conduct performance
testing at loads other than maximum, in case alternate operating limits for those periods are desired. For
the 30 day or other longer term performance testing averaging periods, the final rule does specify a
minimum process operation but expects that measured emissions values to represent normal operations.
As noted elsewhere in the responses to comments, emissions created during process startup and
shutdown are not included in the compliance calculations. All other periods are considered normal
process operations during which the emissions limits apply.

The final rule has been amended to remove the requirement for testing for both the HAP and a surrogate,
for the final rule provides multiple alternative emissions limits and you will have to demonstrate
compliance only with the limit for which you are demonstrating compliance.

Comment 53: Commenter 18015 states that a testing grace period, similar to the 40 CFR part 75 RATA
grace period provisions, should be applied when a source is unable to complete the required testing by
the deadline specified. Additionally, the commenter recommends that a grace period of 720 unit
operating hours should apply to sources that are unable to complete performance tests within the allotted
time period.

Response to Comment 53: The EPA agrees with the commenter that a grace period similar to the 40
CFR Part 75 RATA grace period provisions should be provided for RATA testing and these provisions
have been added to Appendices A and B. The EPA disagrees that grace period provisions should be

25


-------
provided for the performance testing requirements in subpart UUUUU. The part 63 General Provisions
section 63.7(a) provide for an extension of the performance testing deadlines only for situations beyond
the source owner/operators control. The provisions for requesting such extensions and the procedures for
implementing them are explained in greater detail in the "Clean Air Act National Stack Testing
Guidance" released on April 27, 2009.

Comment 54: Commenter 17881 states that clarification is needed with respect to what it means to
"conduct all applicable performance tests for PM (or SO2) and non-Hg HAP metals (or HC1) during the
same compliance test period" (citing section 63.10006). According to the commenter, while this
statement may make limited sense for those units demonstrating compliance via a CEMS, EGUs relying
upon manual sampling methods for the surrogate will not likely be able to conduct concurrent tests for
the associated HAP(s) due to limitations on sampling port availability, possible interferences from
multiple probes inserted at a given stack plane, etc.

Comment 55: Commenter 17881 questions how, when CEMS are being used to measure the surrogate
(i.e., PM or SO2), one would reconcile a 30-day compliance test period for the surrogate with the
relatively short duration run times associated with manual sampling methods for non-Hg metals and HC1
(citing section 63.10006).

Response to Comments 54-55: In response to comments, the final rule has removed all requirements
for duplicative testing of a HAP and a surrogate. Facilities complying with surrogate standard do not
have to perform periodic testing for the corresponding HAP.

Comment 56: Commenter 17881 states that as currently written, section 63.10006(e) requires that the
fuel factor methodology and equations in sections 12.2 and 12.3 of Method 19 (40 CFR 60, Appendix
A-7) be used to convert the results of the performance tests into units of lb/MMBtu of lb/TBtu, as
applicable. According to the commenter, this section should recognize that such calculations need not be
conducted if an EGU has chosen to demonstrate compliance with the mass per unit of electrical output
emission limits.

Response to Comment 56: The final rule has been amended to clarify that only the methodology or
equations required for the specific emission limit will be required.

Comment 57: Commenter 17881 states under Table 1 - Emission Limits for New and Reconstructed
EGUs, that the run times specified for each constituent should be the lesser of 4 dscm or the duration
required to capture a specified amount of PM. According to the commenter, the current volume equates
to a run time of about 4 hours at a typical sample rate of 30 dscf/hr.

Response to Comment 57: The EPA does not believe a change is warranted. The run time is that
needed to get at least 4 dscm. The commenter's suggestion would not change that because, using the
commenter's phrasing the current wording is the same as "the lesser of 4 dscm or the duration required
to capture a specified amount of PM [4 dscm]."

Comment 58: Commenter 17881 questions why (under Table 2 - Emission Limits for Existing EGUs,
for Coal < 8300 Btu/lb, Total PM) the run time is different than the run time for existing units firing
coals > 8300 Btu/lb when the PM emission limit is identical.

Response to Comment 58: The final rule has been amended to fix the clerical error.

26


-------
Comment 59: Commenter 17881 states that (under Table 5- Performance Stack Testing Requirements
for Non-Hg HAP Metals) the exhaust flow and moisture should only need to be determined if you are
complying with the lb/MWh limit. According to the commenter, the O2/CO2 levels should only need to
be determined if complying with the lb/MMBtu standard.

Response to Comment 59: The final rule has been amended to clarify that only the methodology or
equations required for the specific emission limit will be required.

Comment 60: Commenter 17881 questions whether (under Table 5, for HCL and HF) 40 CFR part 60,
Appendix F, Procedure 1 is really applicable to HC1 and HF CEMS.

Response to Comment 60: Based on the comments received that support the use of part 75 reporting
for CEMS, we have added an Appendix B to the rule to set the technical requirements for QA applicable
to an HC1 or HF CEMS if used under this rule. The procedures are largely similar to Appendix F as
proposed but adapt those requirements to fit more closely with approaches taken under Part 75 so that
the existing reporting infrastructure for Part 75 reporting can be easily adapted to support this rule.

Comment 61: Commenter 17881 states that (under Table 5) 40 CFR part 60, Appendix B, Performance
Specification 6 conflicts with the QA requirements in part 63, subpart UUUUU, Appendix A for
auxiliary measurements.

Response to Comment 61: The final rule will be amended to provide consistency with Table 5 and
Appendix A.

Comment 62: Commenter 17881 states under Table 5, for Hg, (bullet a.) Method 20B (sic) contains
alternate provisions for determining the number of sampling points as compared to Method 1.

Response to Comment 62: The final rule has been amended to allow the alternative provisions for
sample point selection contained in Method 30B.

Comment 63: Commenter 17881 states that under Table 5, bullet f., the rule should also contain
provisions for lb/MWh or lb/GWh conversions.

Response to Comment 63: This issue has been addressed in Table 5 and section 63.10007(e) of the
final rule.

Comment 64: Commenter 17881 states that under Table 5, for the LEE testing, moisture and flow
should only be required if you elect to show compliance with the lb/GWh limit or calculate annual mass
using a flow CEMS, in which case moisture would be needed.

Response to Comment 64: The final rule has been amended to clarify that only the methodology or
equations required for the specific emission limit will be required.

Comment 65: Commenter 17681 states that proposed section 63.1001 l(b)(3)(i) appears to require
operators to determine the fuel mixture with the highest content of non-Hg HAP metals and asks if this
determination requires distinction between types of coals (i.e., anthracite, bituminous, subbituminous,
etc.) and between regions (i.e., Illinois Basin coal vs. Appalachian coal).

Response to Comment 65: The final rule no longer includes this provision.

27


-------
Comment 66: Several commenters (19536, 19537, 19538) state that the EPA should strengthen
monitoring requirements for acid gases because one plausible combination of monitoring and FGD
controls is omitted from the proposal. Commenters state that no periodic performance testing and
operating parameter monitoring are specified for units that use CEMS but have no controls.

Response to Comment 66: The final rule does not include the control device continuous parametric
monitoring of the proposal and replaced that monitoring with greater reliance on CEMS for control acid
gases and the PM CPMS for control of HAP metals and filterable PM. The rule also provides the option
to use frequent manual performance testing with the premise the frequent testing (e.g., quarterly) will
ensure that sources must maintain the process and control technologies in condition consistent with
compliance performance on a continuous basis. This includes units that comply with emissions limits
with no add on control devices. As for augmenting CEMS data with additional performance testing, we
believe that CEMS data verified with periodic quality assurance testing and other quality control
measures as required by the rule provide means sufficient to demonstrate compliance with the emissions
limit on a continuous basis and independent of additional performance testing.

Comment 67: Commenter 17174 states that the term "maximum normal operating load," as used in
section 63.10007, is not defined. According to the commenter, facilities use different fuels in different
proportions, depending on many variables such as availability and cost. The commenter asserts that the
EPA should provide a clear definition of maximum normal operating load or representative operating
conditions in section 63.10042. According to the commenter, the EPA should also clearly define how a
source that utilizes more than one fuel should comply with this requirement. The commenter states that
there appears to be an inconsistency between the testing conditions specified in section 63.10007(c) and
(f). According to the commenter, while section 63.10007(c) requires facilities to conduct performance
tests at the "maximum normal operating load," section 63.10007(f) requires facilities to conduct
performance tests under such conditions as the EPA Administrator specifies to the owner or operator
based on "representative performance" of the affected source for the period being tested. (76 FR 25108)

Comment 68: Commenter 17770 states that there is a problem with setting an emission limit that must
be achieved on a continuous basis using results from a periodic performance test. According to the
commenter, a performance test is conducted according to prescribed conditions, i.e., steady state, full
load conditions and provides a "snap-shot" of unit performance representative of those steady state
conditions, and a performance test does not show how that the unit will operate under all conditions and
at all levels of unit operation. The commenter states that typically, a unit will operate above or below the
load conditions during which performance tests are conducted.

Comment 69: Commenter 18935 notes that the proposed minimum sample volumes for metals and HC1
will probably not yield the required detection limits to establish compliance. According to the
commenter, while a responsible emission testing firm will make source-specific calculations as part of
test planning, the proposed sampling volumes may significantly skew the anticipated cost of and time
associated with compliance testing. As a responsible emission testing service provider, the commenter
encourages the EPA to present realistic sample volume and duration information so that sources can
properly budget and prepare for compliance testing.

Response to Comments 67 - 69: The EPA reviewed, and adjusted as appropriate, the final emission
limits and minimum detection levels so that the rule contains appropriate sample volumes and run
durations.

28


-------
Comment 70: Commenter 18021 states that the small degree of alternative requirements with
Administrator's approval is built into the regulation but is concisely stated. The commenter requests
elaboration in at least the preamble that recognizes the variability in design and operating characteristics
of EGUs allowing consideration of alternatives supported with a demonstration during the performance
tests is needed. The commenter requests that the EPA allow demonstration with CEMS and/or operating
parameters in lieu of an emission test after the annual performance test during the first 2 to 3 years.

Response to Comment 70: While the agency appreciates the commenter's support for rule brevity, the
agency does not believe the preamble needs to elaborate on an EGU owner or operator's ability via the
general provisions in §63.8(f) to seek an alternate means of monitoring. The agency finds the last
comment moot, as the rule no longer requires annual performance tests or operating parameter limits for
those EGUs whose owners or operators choose to use CEMS.

29


-------
5A02 - Testing/Monitoring: Averaging times for monitored pollutants

Commenters: 17621, 17623, 17627, 17638, 17681, 17689, 17702, 17705, 17714, 17716, 17718, 17725,
17730, 17736, 17740, 17757, 17758, 17767, 17774, 17775, 17796, 17798, 17800, 17807, 17820, 17873,
17881, 17885, 17902, 17904, 17909, 17925, 17926, 17927, 17928, 17929, 17930, 18014, 18018, 18034,
18037, 18421, 18443, 18498, 18539, 18644, 18831, 19032, 19041, 19114, 19121, 18023

1. Commenter supporting current or shorter averaging times.

Comment 1: Commenter 17926 supports and offers praise for the proposed averaging times in
conducting Hg-related testing. According to the commenter, currently Montana utilizes a 12-month
average in calculating the emissions of generating units. The commenter states that while Montana has
Hg emissions limitations, the averaging times may allow for emissions spikes of Hg. According to the
commenter, the proposed averaging times by the EPA, which are averaged on a rolling basis of 30 boiler
operating days, will assure that facilities are adequately complying with emissions limits. The
commenter also contends that a 30-day averaging time will help to assure that facilities are avoiding
time periods with periodic spikes in emissions.

Response to Comment 1: The agency appreciates the commenter's support for the rule's averaging
time for Hg.

Comment 2: Commenter 17929 states that compliance with the EPA's standards for PM and Hg are not
to be based on a single triplicate "independent sample" at a single "randomly selected] future test
condition" where the EPA has claimed it wishes to provide 99 percent confidence, but rather continuous,
integrative sampling every minute of every day and then averaging for a long-term, 30-operational-day
period. According to the commenter, because the EPA is using a 30-day rolling average rather than a
triplicate sample, the various measures that the EPA uses to account for variability in a triplicate sample
are irrelevant and unnecessary. The commenter states that there is no rationale for an "n" of 3 test runs
in the UPL equation, for an "s2" value, the variance in the single-point emissions data from the top
units, or for a student's t-statistic with a 99% confidence level. The commenter asserts that there is no
rationale at all for the whole UPL calculation unless compliance is to be determined solely based on a
single triplicate sample, which, the commenter asserts, it is not.

Response to Comment 2: The agency uses a number of statistical tools so that poorly performing or
problematic sources can be identified. Basing emissions limits on the average result of three test runs
and adjusting that result to account for most, if not all, false positive results, then setting a
commensurate averaging time that accounts for brief, transient emissions spikes, focuses the agency's
resources on those poorly performing or problematic sources, instead of penalizing inadvertent
occurrences.

Comment 3: Commenter 18421 states that the proposed procedures permit averaging of Hg levels on a
rolling 30 boiler operating day basis, which could result in days when a given boiler is exceeding the
NESHAP limit for Hg emissions. According to the commenter, the EPA should adjust the procedures
for Hg CEMS to ensure continual compliance with the standards of the proposed rule.

Response to Comment 3: The agency disagrees with the commenter, for the procedures for Hg CEMS
as well as Hg sorbent traps are designed to ensure continuous compliance with the rule. As mentioned in
a previous response, establishing an averaging time that accounts for brief, transient emissions spikes

30


-------
focuses the agency's responses on those poorly performing or problematic sources, instead of penalizing
inadvertent occurrences.

Comment 4: Commenter 17975 notes that emission limits for non-Hg metals are based on a 30-day
rolling average that would include startups, shutdowns and maintenance events. Commenter 17975 goes
on to state that the stack tests upon which the agency's PM standard is based do not reflect emission
rates that can be achieved over a 30-day period because stack testing is usually designed to assure
compliance with PM limits that must be met over a three-hour period. The commenter asserts that the
agency's 2009 "Clean Air Act National Stack Testing Guidance," which applies to both MACT and
NSPS, makes clear that stack testing to determine compliance with these short term limits should be
conducted under conditions that "are most likely to challenge the emission control measures of the
facility with regard to meeting the applicable emission standards."1 The guidance further explains that
stack testing should be conducted when boilers are operating at peak capacity, and using the dirtiest fuel
that it can legally burn because stack testing under these conditions is designed to measure the maximum
emissions that will occur within any three-hour period over the course of a year or more.2 The
commenter believes that actual emissions averaged over 30 days during periods when units are operating
at lower capacity with cleaner fuels - are likely to be much lower.

Response to Comment 4: The comment is moot, as the rule no longer has numeric emissions limits
applicable during periods of startup or shutdown.

2.	Commenters supporting annual compliance periods rather than 30-day periods.

Comment 5: Numerous commenters (17623, 17627, 17714, 17716, 17736, 17757, 17774, 17800,
17873, 17885, 17902, 17909, 17930, 18018, 18037, 18498, 18831, 19032, 19041, 19114) state that the
compliance period should be increased from a 30-day rolling average to a 12-month or 365-day rolling
average.

Commenters 17623 and 17774 state that the EPA has authority under the CAA to use discretion to shape
compliance periods and averaging times for MACT limits and suggest that the EPA use a 12-month
rolling average compliance period rather than the proposed 30-day rolling average period, because a 12-
month rolling average still requires compliance reporting every month but helps limit the number of
violations resulting from normal seasonal variability in electricity use and associated emissions.
Commenter 17774 notes that the EPA has used 12-month rolling averages in a number of other MACTs
(e.g., boat manufacturing and magnetic tape).

Response to Comment 5: The agency disagrees with the commenters, noting that for this rule, an
averaging period of 30 boiler operating days, as opposed to a 12-month or 365-day rolling average, is
sufficient to account for normal variability, as well as other brief, inadvertent occurrences.

3.	Support annual averaging due to SSM issues.

Comment 6: Multiple commenters (17714, 17627, 17718, 17757, 17800, 17925, 18831) state that the
proposed rule requires utilities to meet emissions limits at all times including periods of startup and
shutdown but that the ICR stack testing data did not include startups or shutdowns and that it is
inappropriate to establish limits that include startups and shutdowns. Commenters 17714 and 18831

1	EPA, Clean Air Act National Stack Testing Guidance 15, 16 (2009).

2	Id.

31


-------
recognize that the proposed 30-day rolling averaging compliance period is likely to be helpful in
addressing the variability in emissions during normal operations, but commenters do not believe a 30-
day period is sufficient to address inclusion of startup and shutdown emissions. Commenter 17714 states
that absent sufficient stack testing data from real operations that include several periods of unit startup
and shutdown across the range of units included in the affected source category, the averaging period
should be increased to 365 days to accommodate periods of startup and shutdown.

Comment 7: Several commenters (17718, 17627, 17757, 18037, 18539) note that ICR data did not
encompass the full range of operating conditions including changes in operating variables (i.e.,
pulverizers taken out of service, fuel variability causing changes in control equipment operations, etc.)
that a unit experiences in the normal course of operation. According to the commenters, the EPA can
alleviate some of the effect of variability on unit emissions that was not accounted for in the 2010 ICR
testing by allowing annual averaging, while still achieving the same emission reductions.

Comment 8: Commenter 17925 states that while the EPA indicates the 30-day averaging time addresses
concerns with startup, shutdown, and malfunction (SSM), according to some utility industry
experiences, an unexpected period where more than one startup/shutdown cycle occurs will significantly
impact compliance with MACT emission limits. According to the commenter, this is understood by
considering the number of hours involved in a startup and the impact of treatment equipment coming to
equilibrium with the changing temperatures, gas flow rates and pollutant loadings.

Comment 9: Commenter 17800 states that the utility industry has limited experience with some of the
continuous monitoring devices that suggests such spikes can occur and may not be representative of
stack gas concentrations. According to the commenter, the EPA should allow reasonable exemptions for
startup, shutdown and malfunction conditions or lengthen the 30-day rolling averaging time. The
commenter notes that the State of Illinois has adopted a Hg standard that is based on a 12-month rolling
average.

Comment 10: Commenter 17736 states that a 30-day rolling average, especially if SSM periods are
included, makes compliance nearly impossible. According to the commenter, a few hours of ESP
downtime can destroy a 30-day rolling average. The commenter suggests that the use of a 12-month
averaging period helps to ensure that compliance results will not be skewed by SSM periods. The
commenter states that an annualized averaging period is equally effective in reducing the total emissions
as is a 30-day period.

Comment 11: Commenter 17758 states that the EPA's assumption that providing a 30-day averaging
period will smooth out any emissions increases associated with infrequent startup and shutdown periods
is predicated on infrequent startup and shutdown periods of short duration. According to the commenter,
the frequency and duration of startup and shutdown periods varies for different types of units and
different fuels. The commenter states that the EPA's assumption that 30-day averaging addresses this is
unsupported in the record by data from actual unit operations. Accordingly, asserts the commenter, the
EPA has not demonstrated that 30-day averaging will enable affected units to comply with a
continuously applied MACT standard.

Comment 12: Commenter 17774 notes that the use of a 12-month rolling average also assists regulated
facilities in meeting what are extremely strict standards. For example, the commenter states, one of
commenter's PM CEMS is installed on one of the most controlled units in their fleet, which utilizes
ESP, wet FGD and SCR technology. According to the commenter, the data from these CEMS (see
attachment to EPA-HQ-OAR-2009-0234-17774-Al.pdf) show that this unit will not consistently meet

32


-------
the proposed 30-day rolling average PM limit. The commenter states that although this unit typically
operates below the proposed limit, there are numerous events (87 exceedances of a 30-day average in a
2-year time period) where unplanned shutdown/startup events and temporary spikes in PM emissions
push the 30-day rolling average above the proposed limit. Similarly, the commenter notes that Hg
CEMS, which are installed on two of their most controlled units using ESP, wet FGD, and SCR
technology show that these units will not meet, on a consistent basis, the proposed 30-day rolling
average Hg limit. (See attachment to EPA-HQ-OAR-2009-0234-17774-Al.pdf.) According to the
commenter, while these units usually operate below the proposed limit, there are a number of events (93
exceedances of a 30- day average in a 2-year period) where unplanned startup/shutdown events and
unpredictable short term spikes in Hg emissions push the 30-day rolling average above the proposed
limit. It is commenter's experience that the cause of these Hg spikes cannot be attributed to any
particular operating parameter or fuel characteristic that the commenter can reasonably control. The
commenter supports a 12-month rolling average to allow for flexibility in compliance by
accommodating unplanned startup/shutdown events and inevitable spikes in emissions while
maintaining a high level of environmental integrity. According to the commenter, it also will help to
limit noncompliance, and therefore promote overall adherence to the rule. The commenter asserts that
such flexibility will assist in alleviating the very high burden imposed by the proposed Utility MACT.

Comment 13: Commenter 17873 states that averaging time is important in dealing with non-steady state
operations and emissions during these periods should either excluded from the compliance
determination, or the averaging period should be lengthened from a 30-day average to a 12-month
rolling average, calculated monthly. The commenter offers an example of the practical importance of a
longer averaging period when in 2007, Xcel Energy upgraded the Allen S. King Generating ("King")
Plant. The commenter states that this upgrade included the installation of new pollution control
equipment, modification of the plant heat rejection system, and improvements to the boiler and that the
new control equipment consisted of a SCR reactor for NOx control, a spray dryer absorber lime-based,
FGD system for SO2 control, and a pulse-jet cleaned fabric filter for additional PM control. According to
the commenter, the cyclone-fired boiler burns subbituminous coal and is considered to have BDT
equipment installed, and the King Plant's SCR and FGD systems require specific flue gas temperatures
and the boiler to be at specific steam pressures in order to operate properly. According to the
commenter, given this, King cannot operate the SCR and FGD during periods of startup when flue gas
temperatures and steam pressures are lower than required. The commenter states that the plant's current
permit limits require compliance based on lb/MMbtu of SO2 and NOx using a 30-day rolling average,
and the commenter's experience provides strong evidence of the difficult many units will have in
meeting emission units using that averaging approach. At King, the commenter found that permit limits
can be met if there is only a single start-up within a given 30-day period, but additional start-ups
significantly jeopardize compliance for both SO2 and NOx- According to the commenter, it is not
uncommon for King and other similar units to experience more than one start-up within 30 days in cases
of forced outages and even planned maintenance. The commenter states that it is unrealistic and
unreasonable to require compliance with the proposed Hg, HC1, and PM limits on a 30-day rolling
average basis.

Comment 14: Commenter 17904 notes that even one of its best performing units (Oak Grove Unit 1), a
well-controlled unit, would likely not be able to achieve 100 percent compliance. According to the
commenter, this is because the EPA's proposed standards have been set too stringently, even for these
units that were put into commercial operation since 2009 and are equipped with the most advanced,
commercially available controls. According to the commenter, operating conditions and fuel quality can
vary over short time periods, and periods of startup and shutdown can also affect emission rates over
short time periods. The commenter urges the EPA to establish longer averaging times to smooth out this

33


-------
variability. The commenter notes that the EPA has previously explained in response to interagency
comments that its concern with a longer averaging period is that EGU owners may overspend on Hg
control as the result of over-injection of sorbent or lack of sufficient maintenance. According to the
commenter, apparently the EPA believes this would increase owner or operator risk of non-compliance
and liability associated with non-compliance, because owners and operators would decide to only check
control devices once per year. However, the commenter states the length of the compliance period is
extremely unlikely to drive behavior that is not optimal for owner or operator control of emissions and
costs. According to the commenter, it is in the best interest of these parties to both minimize the cost of
control and to maintain compliance. Thus, the commenter states that the EPA's argument against an
annual averaging period is not persuasive. According to the commenter, importantly, longer averaging
times would simply help redress the variability issues. The commenter asserts that the EPA would only
create the same variability problems if it promulgated standards with longer averaging times but at the
same time applied its UPL variability analysis to set a lower numerical emissions rate.

Comment 15: Commenter 17774 states that despite the EPA's statements in the preamble that it will
provide a measure of leniency with regard to instances of malfunction, they have serious concerns about
the attendant uncertainty regarding how affected sources may be penalized. According to the
commenter, in addition, even with a promise of reasonableness from the EPA, regulated entities could
still be vulnerable to citizen suits. Although the commenter supports the EPA's proposal that not all
malfunction events would necessarily result in a violation the commenter asserts that regulated facilities
would still be subject to significant EPA and state discretion concerning such occurrences and would be
forced to shoulder the burden of proving an affirmative defense. According to the commenter, these
requirements distract from efficiently reducing emissions consistent with the EPA policy and as such,
are not an acceptable approach to periods of malfunction.

Comment 16: Commenter 19121 states that it appears that the compliance averaging time for
operational limits is substantially more stringent than for the numerical emissions limitations set under
the proposed rule. According to the commenter, this will have the effect of further limiting operational
flexibility. It will also negate the effect of blending in startup/shutdown events so that MACT limits can
be met. The commenter states that although a given numerical limit could be met on a 30 boiler-
operating day average, operating limits could not be met on 1-hour, 4-hour, or 12-hour periods blending
the same events. According to the commenter, continuous compliance should be shown based upon
emissions monitoring only.

Comment 17: Commenter 17740 states that the EPA's conclusion that EGUs "do not normally startup
and shutdown frequently" effectively, and incorrectly, assumes that all units are operated as base load
units. As the Seventh Circuit recognized in United States v. Cinergy, "[utilities operate power
generation equipment in three general ways: baseload, cycling, and peaking." 623 F.3d 455, 459 (7th
Cir. 2010). According to the commenter, non-baseload units start up and shut down frequently, and even
supposed "base load units" are often, and unpredictably, shut down for unit "trips" (i.e., unplanned
outages). The commenter asserts that the EPA further assumes that basing the proposed standards on a
30-day rolling average will account for any increased emissions during periods of startup and shutdown
and that the EPA made a same faulty assumption in the proposed rule that preceded the Boiler MACT,
see 75 FR 32,012-13, and rejected it in the final rule, see 76 FR 15,642. According to the commenter,
the EPA has not demonstrated that the 30-day rolling average will address the substantial operating
variations among EGUs or even within an EGU. While a number of the MACT pool EGUs are newer,
well controlled, baseload units, the commenter asserts that the EPA cannot assume that the entire
universe of coal-fired EGUs, even baseload units, will operate as reliably as newer units. According to
the commenter, as EGUs age, they tend to experience more forced outages than when they were newly

34


-------
constructed; thus, an older EGU with highly efficient controls may not be able to meet a 30-day standard
in months in which it experiences a number of forced outages.

Response to Comments 6-17: The final rule established work practices for periods of startup and
shutdown, which addresses this concern about the impact of such periods on compliance with a 30-day
rolling average. See the preamble discussion for further detail on EPA's rationale for excluding startup
and shutdown periods from calculating compliance with the emission limits in the final rule. For
malfunctions, EPA provides an affirmative defense for exceedances that may be caused by such events.
With these provisions, EPA believes that the concerns raised in these comments are appropriately
addressed without modifying the general use of 30-day rolling averages for this rule. See also preamble
and response to comments below explaining EPA's approach to malfunctions. With respect to the one
comment about the proposed operating parameter limits being based on a shorter time period, those
comments are now moot given the lack of operating parameter limits with 12-hour or similar averaging
periods specified in the final rule.

4. Supporting longer averaging time due to health outcomes.

Comment 18: Several commenters (17716, 17725, 18014, 18498) state that a 30-day rolling average
compliance period is inconsistent with health effects and that the EPA has presented insufficient
findings related to the prerequisites for reaching an "appropriate and necessary" determination for
regulating EGUs under CAA section 112(n)(l)(A). Several commenters (17716, 17725, 18498) state
that even if one accepts the EPA's explanation of the potential hazards of the relevant HAP, that
explanation does not justify compliance on a rolling 30-day basis because no exceedances of HC1, HF or
HCN standards were documented in the 1998 Utility HAP Report to Congress and no hazards to public
health have been established based on HAP emissions from EGUs. Commenter 17716 takes exception to
the EPA's direction of attention to alleged potential hazards that might result from long-term cumulative
exposure in the absence of any short-term exposure concerns associated with emissions from EGUs
because, according to the commenter, nothing has been shown to suggest a hazard from 30-day exposure
to current EGU HAP emissions, and in these circumstances, the value of monthly testing is neither
apparent nor warranted to protect against a cognizable risk. Commenter 17716 goes on to state that
absent a showing of need or benefit for monthly testing, yearly testing should be applied as providing
the requisite level of protection against the inchoate long-term potential risks alleged to be involved."

Comment 19: Multiple commenters (17627, 17757, 18498, 18539; 18644, 19032, 19041, 19114) state
that the EPA has not demonstrated why a 30-day averaging period would be more protective to human
health than an annual period, particularly for Hg emissions, where mass emissions are the key issue.
Commenter 17725 states that no short-term exposure concerns associated with the ambient level
contributions from EGU. According to the commenter, if any risk exists at all, the EPA can only suggest
that they are related to chronic, long-term exposure or related bioaccumulation manifesting over years;
thus, if the emissions from a source are a little higher one month due to a control upset but are then
offset by lower emissions during the next month(s), the health impact would be essentially identical to a
source with no "ups and downs" in the monthly emissions but with the same annual emissions.

Comment 20: Multiple commenters (17716. 17689, 17702, 17718, 17798, 17885, 18037, 18443) state
that the risk and concern expressed by the EPA centered around long term emissions (e.g.,
bioaccumulations) and that therefore the use of a rolling average that would need to be calculated every
day is unwarranted. Commenters suggest that compliance should only be assessed on an annual basis
and this would still produce the same control and environmental outcome. Commenter 17798 states that
the EPA should distinguish and structure requirements based on whether the hazardous pollutant creates

35


-------
acute or accumulative impacts. For example, according to the commenter, acid gases are of concern for
even very short periods of exposure whereas for metals, including Hg, the impacts are more related to
the total loading and accumulation in the environment.

Response to Comments 18 - 20: The EPA establishes the limits based on the maximum achievable
control technology, not the specific timeframe over which health risks from the applicable hazardous air
pollutants may manifest themselves. The monitoring and testing provisions are established to ensure
continuous compliance with those standards. The EPA believes that the final rule's monitoring and
testing provisions provide a cost-effective means of ensuring continuous compliance with the standards,
and take advantage of a range of options, with significantly reduced monitoring and testing where the
margin of compliance indicates a reduced likelihood for potential noncompliance situations.

Comment 21: Several commenters (17716, 17725, 18014, 18498) suggest the use of block averages for
PM, Hg, and HC1 CEMS data as performance indicators, not as direct measures of compliance.

Response to Comment 21: An Hg CEMS and an HC1 CEMS are options for use as the performance test
method for the applicable Hg and HC1 emission limits. If a source is concerned about the use of these
methods in such a manner, the rule provides for other options (sorbent trap monitoring for Hg and stack
testing for Hg and CI). There is no use of a PM CEMS as a direct performance test method for the PM
emission limit. The PM CPMS is used as an operating parameter monitoring approach to demonstrate
compliance with a site-specific operating limit expressed in terms of the raw output of the PM CPMS.
The operating limit aids in ensuring that the source is operated and maintained in accordance with good
air pollution control practices to minimize emissions so that the source can continue to operate in
compliance with the emission limit as demonstrated in a periodic stack test.

Comment 22: Several commenters (17689, 17885, 17930, 18443, 19032) support an annual average
because most utilities will be using a sorbent trap because Hg CEMS technology is not likely to yield
accurate and precise measurements. According to the commenters, sorbent traps have approximately 2-
week collection intervals, so should a problem develop with one sample, 30-day compliance
demonstrations would be extremely problematic. Further, asserts the commenter, as the EPA is well
aware, a major factor in Hg emissions concentration is the Hg fuel content, so it is quite possible the Hg
content variability in coal utilized over a 30-day period could determine non-compliance regardless of
best efforts of a utility to limit Hg emissions. Commenter 17930 states that Hg peaks are often
experienced month-to-month and the current rule should revise the averaging time to annual to account
for this variability.

Response to Comment 22: The agency believes a number of Hg CEMS will be able to provide
continuous data regarding mercury emissions; should an owner or operator choose to use sorbent traps
in lieu of Hg CEMS, such an owner or operator will be able to use his knowledge regarding process,
mercury fuel content, and control device operation to tailor the time the sorbent traps collect samples.
Note that sorbent traps are allowed a maximum sample time of 15, not 30, days.

5. CEMS uncertainty.

Comment 23: Several commenters (17725, 18014, 18498) state that in reviewing the CEMS data for
compliance purposes, the EPA would need to take into account the uncertainty of the measurements
along with the emissions reported for other months.

36


-------
Response to Comment 23: The CEMS data will be quality-assured in accordance with the rule
requirements. Provided the monitoring systems are producing valid, quality-assured data, EPA will use
all such data in determining compliance with the emission limits monitored by such a device, in the
same manner as any other performance test data may be used. These principles have been in use by EPA
since first promulgating CEMS QA provisions in Appendix F to part 60 in the 1980s. The data under
this rule will be treated in accordance with those longstanding principles and regulatory provisions.

6.	30-day rolling average is inappropriate.

Comment 24: Several commenters (17705, 17716, 17725, 18014) state that the 30-day rolling average
is also inappropriate because it repeatedly penalizes sources for a single emission controls upset because
if a source experiences very high emissions one day (startup, shutdown, or malfunction) that single day
will affect the 30-day average calculated not only for that day, but also the calculated averages for the
next 29 days). Several commenters (17725, 18014, 18498) refer to this situation as not only double
jeopardy but thirty-fold jeopardy. Commenter 17800 states that due to the stringency of the proposed
standards and the measurement methods required (CEMS and/or emission testing) a short term variation
in the process could result in a source being out of compliance for a significant period of time.

According to the commenter, one high magnitude but short duration spike in emissions will impact the
30-day rolling average for an extended period of time even if a source takes immediate corrective
action.

Response to Comment 24: The final rule includes a work practice in lieu of numerical limits to apply
during periods of startup and shutdown. The scenario the commenter raises relative to startup and
shutdown emissions inordinately affecting the 30 day average should be moot. The rule also includes
provisions for the source owner to apply for an affirmative defense of excess emissions that occur during
malfunctions. We believe that the rule addresses these comments such that the source owner has the
flexibility to manage process and control device operations in a timely fashion relative to the averaging
time of the standards. See also response to Comments 6 through 17, above.

7.	Support annual fuel variability.

Comment 25: Several commenters (17702, 17725, 17930, 18018, 18644) state that a 30-day rolling
average for compliance may be unworkable for some units and is unnecessarily restrictive. The
commenters state that many coal-fired EGUs are designed to bum a variety of coal types. According to
the commenters, trace chemical constituents (metal, sulfur, halogen, Hg, chlorine) of coals from the
same source can vary significantly. The commenters assert that in certain cases, variations in chlorine
content in a coal may mean the difference between compliance and noncompliance with the EPA's
proposed air toxics rule.

Response to Comment 25: As the rule no longer contains fuel content metals or acid gas operating
limits but maintains the UPL calculations to account for variability, as discussed elsewhere, the agency
believes a 30 boiler operating day rolling average will be sufficient to account for normal variation in
fuels for sources that use a CEMS to demonstrate compliance with the standards in the final rule.

Comment 26: Commenter 18443 states that a major factor in Hg emissions concentration is the Hg fuel
content. According to the commenter, the currently proposed Hg limit does not account for the
variability of Hg in the fuel or varied plant operations and draws only on 40 hand-picked best
performing units, and it is possible that the Hg content in a particular coal shipment could be high

37


-------
enough over a 30-day period to exceed the Hg limit despite the best efforts of a utility to limit Hg
emissions.

Response to Comment 26: The agency disagrees with the commenter and notes that the Hg emissions
limit was established using data from the best performing sources that were adjusted statistically using
the UPL procedure to account for variability. Properly maintained and operated Hg control devices
should enable source owners or operators to meet the rule's Hg emissions limit.

8.	Suggested alternative compliance approaches.

Comment 27: Commenters 17928 and 18644 state that the 30-day averaging time is too short to account
for transient events (startup, shutdown and upset conditions), and variability of CEMS data. In order to
facilitate the practical use of facility averaging provisions outlined in the proposal, the commenters
recommend that a minimum 90-day averaging time be considered, to account for uncontrollable events
and emissions variability. Commenter 17928 notes that there has been little real world experience with
HC1, PM and Hg CEMS data in general with EGUs and with the lower measurement levels that will be
needed to demonstrate compliance. The commenter is concerned that the proposed averaging time may
not be long enough to be useful for a facility averaging plan, since an extended maintenance outage of
the over-controlled units at a facility could force the other units in an averaging plan to be out of
compliance.

Response to Comment 27: See response to Comments 6 through 17 and 24, above.

Comment 28: Commenter 19121 encourages the EPA to reconsider increasing either the averaging time
for limits or the actual PM or Hg limits. According to the commenter, based on recent testing, the
commenter's unit is proven to be one of the lowest emitters of Hg in the nation. The commenter notes
that the State of Utah has set a Hg limit that is more strict than that the EPA is proposing but that the
State rule requires an annual averaging period. According to the commenter, this is an example of
balance between limits and limits averaging that would still be protective of human health and the
environment, and meet the requirements of NESHAPS.

Response to Comment 28: As mentioned in earlier responses, the agency believes the rule's averaging
time appropriately accounts for brief, transient emissions spikes enabling the agency to focus its
response on poor performing or problematic sources, instead of penalizing inadvertent occurrences.
Given that the commenter's EGU appears to meet a more stringent state Hg standard, it should have no
problem meeting the standard contained in the rule.

9.	Requests for clarification/explanation.

Comment 29: Commenter 17638 urges the EPA to clarify that a "30 operating day rolling average" is
determined by averaging all applicable hours in the 30-day period. According to the commenter, in some
cases, the proposed rule appears to indicate that a new daily average would be calculated each day and
then 30 daily averages would be averaged to determine the 30-day average, while other language
appears to indicate that all of the hourly emissions for the preceding 30 boiler operating days would be
averaged to determine the 30-day rolling average. According to the commenter, defining a 30-day period
based on daily averages is not fair to units that frequently cycle on and off and could weight a 15-minute
period equally to a 24-hour period.

38


-------
Response to Comment 29: The final rule clarifies that the average is based on all valid hourly averages
during each 30-day rolling average period. Hourly averages are not summed to a daily average as an
intermediate data value for purposes of determining each 30 boiler operating day average.

Comment 30: Commenter 18034 states that the rule must be revised to provide for proper calculation of
emissions during a malfunction. The commenter observes that section 63.10005(1) only applies to
startup and shutdown operations. According to the commenter, if power production during a
malfunction approaches zero, calculated output-based emissions will spike exponentially. The
commenter states that any malfunction causing power production to cease completely for more than an
hour while the boiler is in operation will result in the calculated emissions becoming infinite for that
hour as will the calculated rolling average that includes that hour and that the 30 boiler operating day
average does not address this issue, because Appendix A, Section 6 (76 FR 25144), Equation A-4
requires Hg emissions to be calculated on an hourly basis before calculating the 30 boiler operating day
average according to Equation A-5. According to the commenter, this issue does not appear limited to
Hg emission calculations, as proposed section 63.10010 requires that the 30-boiler-operating-day rolling
average for other pollutants be determined as the average of all the hourly emissions data for the
preceding 30 boiler operating days. The commenter indicates that the proposed rule does not appear to
contemplate malfunctions in the power production side of a facility and under some circumstances
require sources to divide by zero when calculating emissions.

The commenter suggests that the calculation for compliance with the 30 boiler operating day average for
the proposed NESHAP rule could be revised to be consistent with how the EPA has proposed
demonstrating compliance with proposed revision to 40 CFR 60 subpart Da, i.e., the sum total emissions
for the 30 boiler operating days divided by the sum total output over the 30 boiler operating days.
According to the commenter, as the EPA has proposed the rule, sources would be automatically in
violation of the rule for even miniscule emission rates during a malfunction in which power production
ceased for more than an hour.

Commenter 17755 states that a boiler is a separate unit from the generator and can be operated
independently, and the boiler units can and do combust fuel without producing electricity (i.e., during
SSM and maintenance periods). The commenter notes that the emission limits in lb/MWh could only
apply when the generator is producing electricity (MWh), that if not producing electricity then the MWh
would be zero and would produce an invalid lb/MWh ratio, and that most excess emissions occur during
SSM and maintenance when generator is not operating, and the commenter questions whether emissions
that occur when the generator is not producing electricity would be unregulated for these new sources.

Response to Comment 30: Sources are required to comply with the standards at all time, including
periods of malfunction. To the extent a source experiences a malfunction that causes the boiler to shut
down, the emissions during that period must be included in the 30-day averaging period and, if the
malfunction causes the source to exceed the limit for the applicable 30-day averaging period, the source
is in noncompliance and subject to penalties unless the source demonstrates that the affirmative defense
applies.

The commenter is correct that it may not be possible to demonstrate compliance with the output-based
emissions standards under the scenario outlined above. We do not agree, however, that a source would
automatically be in violation of the standards because the source could demonstrate that during those
periods the source was meeting the applicable input-based standard contained in the final rule. An
existing source complying with the output-based limits during periods of normal operation would have
to demonstrate that it complied with the applicable input-based standards during the malfunction event.

39


-------
The source will need to include in its malfunction report the additional calculations and an explanation
to demonstrate that the source complied with the standard notwithstanding the malfunction event.
Sources complying with the input-based limit would not have to take additional steps to demonstrate
compliance during the malfunction event. For these reasons, we are not amending the final rule in the
manner suggested by the commenter.

Comment 31: Commenter 17705 recommends that the final rule define "boiler operating day" as a 24-
hour period during which fossil fuel is combusted in a steam-generating unit for the entire 24 hours to
ensure that compliance is always based on at least 720 hours of operation. Commenter 17705 contends
that the EPA should specify a minimum number of operating hours necessary to calculate a 30-day
rolling average; if the requisite number of hours is not obtained, the EGU should have the option of
combining data from that period with the data from the next 30 boiler operating day period until the
requisite number of hours is obtained. According to the commenter, the EPA specified a similar
procedure in the 40 CFR Part 60, subpart Da provisions for calculation of a 24-hour average in section
60.48Da(g)(3), which requires a minimum number of valid hours to calculate an average.

Response to Comment 31: The EPA disagrees. See responses to comments under Comment Code
5A12 of this document for further discussion on data availability.

Comment 32: Commenters 17740 and 17767 request the EPA to provide clarification to address the
following factors: 1) the number of valid data points or minutes required for a valid operating hour, 2)
the number of valid data points or minutes required for a valid operating day, and 3) the number of valid
data points required for a valid 30-day average.

Response to Comment 32: Section 63.8(g)(2) provides the general rules for hourly averages for all
CEMS. There is no minimum for a valid operating day, as an operating day is a day in which fuel is
combusted and is not dependent on obtaining valid monitoring data in that day. There is no minimum
number of data points for a 30-day average. See responses to comments under Comment Code 5A12 of
this document for further discussion on data availability.

Comment 33: Commenter 18023 requests clarification with respect to the method to calculate the 30
operating day rolling average. According to the commenter, in some cases, the proposed rule appears to
indicate that a new daily average would be calculated each day and then 30 daily averages would be
averaged to determine the 30-day average, while other language appears to indicate that all the hourly
emissions for the preceding 30 boiler operating days would be averaged to determine the 30-day rolling
average. The commenter provides some examples of their confusion, and asserts that:

•	Table 8 in the proposed rule suggests that the 30-day rolling average is calculated as the average
of 30 individual boiler operating day values (Proposed Table 8 (7.b) (convert "hourly emissions
concentrations to 30 boiler operating mg/dscm values").

•	Proposed section 63.10010(g)(5), however, specifies that a 30 boiler operating day rolling
average is calculated as "the average of all of the hourly particulate emissions data for the
preceding 30 boiler operating days." 76 FR 25,112.

According to the commenter, several other references, e.g., 76 FR 25,097, 25,111, suggest that the EPA
intends the 30 boiler operating day rolling average to be based on all the hours in a 30-day period rather
than the 30 daily averages. The commenter urges the EPA to clarify that a 30 boiler operating day is
based on the average of all applicable hours in the 30-day period. According to the commenter,

40


-------
finalizing the rule based on the average of 30 daily averages would be challenging if the unit frequently
cycles on and off, and further, the daily averaging approach would not be fair because it would weight a
15-minute period (i.e., one boiler operating day) as being equal to a 24-hour period (i.e., also one boiler
operating day).

Response to Comment 33: The final rule clarifies that the average is based on all valid hourly averages
during each 30-day rolling average period. Hourly averages are not summed to a daily average as an
intermediate data value for purposes of determining each 30 boiler operating day average.

Comment 34: Commenter 17927 requests clarification of the averaging periods which will be used to
demonstrate continuous compliance with the applicable emission limits in the proposed rule.

Response to Comment 34: Averaging periods apply for emission limits where a CEMS is used to
determine compliance and for the sole remaining operating limit where a PM CPMS is used. In these
situations, the final rule uses a consistent 30 boiler operating day rolling average, based on all valid
hourly averages during each successive rolling 30 operating day period.

Comment 35: Commenter 17681 states that section 63.10031(d)(2) of the proposed rule appears to
require a description of the deviation in the compliance report. Commenter 17681 asks for clarification
of when compliance is determined within the proposed 30-day compliance period; the commenter asks
"If an event occurred on December 31 and the 30-day average starting on December 31 and ending on
January 30, would that deviation be required to be reported in the January 31 compliance report? And if
so, how would a facility know that such an event would deviate from the 30-day average until the end of
that 30-day averaging period unless the deviation was extreme?"

Commenter 17730 notes that the EPA has proposed a new averaging time for the emission standards as
a 30 boiler operating day average which appears to be different than the historical use of the 30-day
rolling average and requests that the EPA provide an explanation of why the EPA is seeking to change
the manner in which the averaging times for emission standards have historically been calculated
at EGUs. Commenter 17730 believes that the EPA should not impose a more restrictive averaging time
for the proposed emission standards.

Response to Comment 35: The rolling average uses a 30-day rolling period as calculated at the end of
each successive operating day, based on all valid hourly averages in the preceding 30 boiler operating
days. In terms of reporting, a deviation that occurs in January would not be included in the report that
must be submitted by the end of January, as that report covers the time period of July 1-December 31.
The agency disagrees with the commenter's view that a 30-boiler operating day rolling average is
inconsistent with historical averaging times for this industry. For example, the new source performance
standard, subpart Da for electric utility steam generating units in existence for over 30 years, uses 30
boiler operating days for the rolling emissions averaging period.

Comment 36: Commenter 17775 states that once the operating limit is established, proposed section
63.10010(g)(5) specifies that a 30 boiler operating day rolling average is calculated as "the average of
all of the hourly particulate emissions data for the preceding 30 boiler operating days" (citing 76 FR
25,112/2). According to the commenter, proposed Table 8, on the other hand, suggests that the 30-day
rolling average is calculated as the average of 30 individual boiler operating day values (citing proposed
Table 8 (7.b) (convert "hourly emissions concentrations to 30 boiler operating mg/dscm values")).
According to the commenter, calculating and averaging separate boiler operating day values would

41


-------
make the limit much more stringent for any period that includes a startup or shutdown. According to the
commenter, regardless of which the EPA intended to propose, neither has been sufficiently supported.

Response to Comment 36: The final rule clarifies that the 30-day average is based on all valid hourly
averages from the PM CPMS in the preceding 30 boiler operating days, with no intermediate daily
values used to determine the 30-day average. The agency disagrees with the commenter's suggestion
that the 30-boiler operating day rolling average period lacks sufficient support; use of a 30-boiler
operating day rolling average period data management during startup and shutdown periods are
discussed elsewhere in this document.

Comment 37: Commenter 17796 suggests that the Hg compliance metric be stated succinctly in section
63.10010(f). According to the commenter, it is clearly stated in section 63.10010(g)(5) that compliance
is based upon a 30-day rolling average emissions rate on a daily basis. However, the commenter was
unable to find this language for the Hg compliance limit for CEMS. The commenter asserts that Section
63.10010(f) refers the reader to Appendix A, but Appendix A does not state the compliance metric.

Response to Comment 37: See Section 6 of Appendix A to the final rule for the calculation procedures.

Comment 38: Commenter 17807 states that the rule proposes to use heat-input-weighted emission
limits based a 30-day rolling average. According to the commenter, the rule is not clear on how to
calculate the 30-day rolling averages. The commenter proposes calculating a daily total for each
constituent, summing the mass and heat input and then calculating the rolling average.

Response to Comment 38: The final rule clarifies that the average is based on all valid hourly averages
during each 30-day rolling average period. Hourly averages are not summed to a daily average as an
intermediate data value for purposes of determining each 30 boiler operating day average. See also
Section 6 of Appendix A to the final rule for Hg calculation procedures.

Comment 39: Commenter 17820 states that the 30-day rolling average limits should contain at least 30
full days of operation.

Response to Comment 39: The EPA disagrees. A boiler operating day is a day in which any fuel is
combusted, and each such day is a day for purposes of calculating the average.

Comment 40: Commenter 18014 states that Table 8 requires the source is to convert "hourly emissions
concentrations to 30 boiler operating mg/dscm values," which suggests that compliance is assess based
on the average of 30 individual daily values. However, according to the commenter, section
63.10010(g)(5) states that 30-day rolling average is calculated as "the average of all of the hourly
particulate emissions data for the preceding 30 boiler operating days."

Response to Comment 40: See response to Comment 33, above.

Comment 41: Commenter 18023 requests clarification on the averaging times for operational
parameters. According to the commenter, the EPA has provided four inconsistent descriptions as to how
the operational parameter limits would be set {i.e., 90 percent of the test average, the lowest 1-hour
average, the 12-hour block average, and the average of three minimum values). According to the
commenter, the electric utility and industry has no way of knowing which of the definitions the EPA
intended to propose. According to the commenter, the EPA must adopt a definition that provides
sufficient flexibility to account for changes in unit operations. The commenter states that the average of

42


-------
three runs and the lowest 1-hour average are clearly unreasonable because, by definition, there will be
values during the testing that are above and below the average and, on a longer term basis, these values
may vary even more.

Response to Comment 41: See response to Comment 36 above for the only remaining operational
parameter that applies under the final rule.

10. Rule language corrections.

Comment 42: Commenter 17775 believes that the reference to the 30 boiler operating day compliance
period for PM in proposed Table 8 (7.b) is inconsistent with the reference in proposed section
63.10010(g)(5) because proposed Table 8 (7.b) suggests that only 30 daily values are averaged while
section 63.10010(g)(5) indicates that up to 720 hourly values are averaged. Commenter 17775 believes
that calculating and averaging separate boiler operating day values would make the limit much more
stringent for any period that includes a startup or shutdown and concludes that "[RJegardless of which
EPA intended to propose, neither has been sufficiently supported. "

Response to Comment 42: The final rule clarifies this issue; see response to Comment 33, above.

Comment 43: Commenter 17638 requests a mass-based alternative compliance option by converting the
existing rate-limit (pounds per million Btu) to a mass-limit (pounds per hour with an annual average),
based on the unit's permitted heat input. The commenter notes that Florida has recent positive
experience in utilizing mass-based limits in permits, achieving substantial environmental benefits while
lessening the burden on the source. According to the commenter, the EPA also has extensive experience
developing NESHAP compliance requirements on a mass basis, having promulgated at least six such
regulations (40 CFR part 63, subparts MMM, XXX, GGGGG, GGGGGG, LLLLLL, and NNNNNN).
The commenter further notes that mass rate were used in the modeling supporting the rule and well as in
setting the standards (using stack tests date).

Response to Comment 43: While the EPA appreciates the suggested alternative, we have not
conducted analyses to assess what specific limits would be necessary to meet MACT statutory
requirements under this alternative scenario and believe that the proposed format provides an adequate
means of limiting emissions in accordance with the statutory provisions and in such a way as can be
monitored and tested for compliance. Thus, the EPA does not believe this type of alternative is
necessary or supported at this time.

Comment 44: Commenter 17881 believes that Equation 5 may not always yield an accurate 12-month
rolling average emission rate when there is a large disparity in the total monthly heat input (or steam
output) across all units included in the averaging plan. According to the commenter, specifically,
Equation 5 gives each monthly average emission rate used to calculate the 12-month rolling total an
equal weighting (i.e., 1/12, or 8.33 percent). The commenter suggests that it would be more accurate if
the 12-month rolling average emission rate was calculated as follows:

Where, Eavg = 12-month rolling average emissions rate (lb/MMBtu heat input; lb/TBtu for Hg).

Average weighted emission level for month i for PM, HC1, HF, non-Hg HAP metals or
Er,	= Hg, in units of lb/MMBtu (lb/TBtu for Hg) of heat input, calculated consistent with

63.10009(f)(1).

Hb;	= Total heat input for all units included in the averaging plan for month I, in units of

43


-------
MMBtu.

Response to Comment 44: The rule replaces a 12-month rolling average with a quarterly weighted
average. As the monthly weighted average (ER,) already makes the adjustment suggested by the
commenter, per Equation 3 or Equation 4, the agency sees no reason for keeping Equation 5, so it has
been removed from the rule.

Comment 45: Commenter 17881 requests clarification, with respect to Equations 1-5, as to the value of
"Er" in those cases where the "performance test" consists of the use of a CEMS to determine a 30-day
rolling average emission rate. According to the commenter, as 30-day rolling averages at the end of a
given month could include several days worth of data from prior months (assuming that operation is not
continuous), there is a high degree of likelihood that the 30-day rolling average emission rate at the end
of a month will not line up with the associated calendar month, thereby introducing a disconnect
between the average emission rate and heat input value used for weighting purposes. The commenter
states that Equations 1-4 should specify procedures for reducing CEMS data into average values for
purposes of the "Er" term. The commenter suggests a simplistic approach would be to average all valid
1-hour emission rates determined during each calendar month for purposes of Equations 3 and 4.

Response to Comment 45: The final rule includes clarification of the emissions averaging procedures
and calculations to be consistent with calculating compliance with the 30 boiler operating day average
for emissions rates elsewhere in the rule. The revised procedure also allows for using CEMS data in
combination or in lieu of performance testing data for determining compliance with the emissions limits.

Comment 46: Commenter 17621 states that individual measurements that comprise the baseline data
pool are incompatible with anticipated compliance measurements. According to the commenter, the
EPA approach (as stated on FR 25041) to calculation of a UPL is based on an average of three
compliance test runs, each of which follows the underlying measurement protocol that was used for the
component baseline data. According to the commenter, compliance options in the proposal typically are
at variance with this requirement. The commenter asserts that most require compliance to be determined
on a 30-day rolling average using a CEMS. According to the commenter, it should be realized that the
statistical properties of these two monitoring approaches are different. (See statistical study provided in
Appendix D.)

Response to Comment 46: The commenter appears to confuse the agency's standard setting activities
(that include UPL calculations) with collection of CEMS data. The compliance options that rely on use
of a 30 boiler operating day rolling average are not at odds with the statistical approach for determining
the emissions limit. Use of the statistical approach provides a tangible measure of variability that is a
component of the emissions limit, while use of CEMS supplies data that for well-operated EGUs are
expected to be equivalent or less than the emissions limit 99 of 100 times. As mentioned in earlier
responses, establishing an emissions limit in this fashion allows the agency to focus on the poorly
operated or problematic EGUs.

44


-------
5A03 - Testing/Monitoring: Fuel analysis methods

Commenters: 17316, 17386, 17402, 17621, 17715, 17718, 17722, 17725, 17730, 17731, 17754, 17758,
17760, 17775, 17781, 17796, 17800, 17801, 17807, 17808, 17816, 17820, 17821, 17881, 17902, 18014,
18015, 18025, 18428, 18447, 18483, 18498, 19033, 19114, 19121, 19536, 19537, 19538

1.	Exempt natural gas.

Comment 1: Commenters 17316 and 17386 request that the EPA exempt the fuel analysis of natural gas
for dual fuel-fired units that fire gas. According to the commenters, in particular, in sections
63.10005(c)(1) and (2), and 63.10006(s), the provisions requiring a fuel analysis for "each type of fuel
burned" should explicitly exclude pipeline natural gas. The commenters state that the exemption should
be based on natural-gas-fired units being both insignificant source of HAP and otherwise being exempt
from the rule. The commenters also suggest that section 63.10005(c)(4), which provides an exemption
from the performance of an initial fuel analyses if a unit burns a single fuel type, be extended to
exemption any unit which burns only one fuel type, aside from pipeline natural gas (i.e., burns 2 fuel
types, but one is pipeline natural gas).

2.	Initial compliance fuel analysis.

Comment 2: Commenter 17316 states that that it is unclear why units that burn a single fuel type are
exempt from conducting an initial compliance fuel analysis, which appears to be the intent of section
63.10005(c)(4). The commenter believes the rule seems to be saying that units which intend to
demonstrate compliance by fuel analysis are not required to conduct an initial compliance
demonstration.

Comment 3: Commenter 17775 requests the EPA clarify the requirements for EGUs combusting single
fuels. Although proposed section 63.10005(c)(4) suggests that such EGUs are exempt from any initial
fuel analysis, proposed section 63.10011(c)(1) only appears to exempt such EGUs from the requirement
to determine the fuel "mixture" that would result in the maximum emission rates. The commenter
assumes the EPA intended liquid oil-fired EGUs demonstrating compliance through fuel analysis to
conduct an initial demonstration using fuel analysis, but that such EGUs that combust only a single fuel
type are not required to make any other demonstrations regarding that sample. The commenter believes
the EPA should confirm that understanding in the final rule and provide consistent language in the two
provisions.

Comment 4: Commenter 17722 notes that section 63.10005 exempts units firing "a single type of fuel"
from the fuel sampling and analysis requirements. According to the commenter, the rule does not define
what constitutes a single fuel. The commenter questions if the definition is as broad as coal, natural gas,
and fuel oil, or more narrowly defined by ranks (e.g., bituminous, subbituminous, lignite) or even more
narrowly ranked by mine location or even coal seam.

Comment 5: Commenter 17775 suggests for EGUs opting to demonstrate compliance using fuel
analysis (as opposed to performance testing), the EPA should clarify or remove the reference to
operating limits. The commenter believes proposed section 63.10005(c) inexplicably refers to
requirements to establish operating limits under section 63.10011 and Table 8. According to the
commenter, the only sections of section 63.10011 or Table 8 that could have any applicability to EGUs
complying through fuel analysis are the fuel input emission rate calculations in proposed section
63.10011(c) and the fuel pollutant content restrictions in Table 8 (6). The commenter suggests the EPA

45


-------
make clear in the rule that the other operating limits in those provisions do not apply to units
complying through fuel analysis.

Comment 6: Commenter 17881 notes that 63.10011(c) is unclear how fuels not covered by the rule
(i.e., natural gas) factor in when co-fired with fuels which are subject to the rule.

Comment 7: Commenter 17881 notes that due to the limited number of samples required (3), the P90
calculation in section 63.10011(c) could show a value much greater than the arithmetic average. The
commenter believes if this potential HC1 content is greater than the limit, the facility should have the
option of periodically collecting fuel samples and showing that the actual results meet the limit.

Comment 8: Commenters 18014 and 18498 suggest EPA clarify fuel sampling provisions for multiple
fuels. According to the commenters, for units firing a single fuel type, fuel sampling and analysis is not
required for supplemental fuels used only for startup, shutdown or for maintaining flame stability per
§63.10005(c)(5)). The commenters believe this exemption does not appear to apply to units that fire
multiple fuel types or blends and suggest EPA clarify this exemption in the final rule.

3. Fuel sampling procedures.

Comment 9: Several commenters (17316, 17386, 17881) state the fuel sampling procedures specified in
section 63.10008(c) and (d) appear to be applicable only to solid fuels and that this section should clarify
that these procedures are not applicable to oil (liquid) fuel sampling. Commenter 17881 requests that the
EPA clarify if there are any requirements for non-solid fuels; for example, it is not clear for a unit co-
firing natural gas if fuel sampling of the natural gas required.

Comment 10: Commenters 17316 and 17386 suggest that fuel sampling for oil-fired EGUs follow 40
CFR 75 Appendix D provisions, which reference ASTM D4057 sampling procedures.

Comment 11: Commenter 17402 suggests the EPA clarify that fuel contaminant levels calculated
during performance tests will be used to calculate maximum contaminant levels for fuel content,
including allowance for some fuel variability, and not dictate the fuel operating limit directly as an
average. According to the commenter, fuel sampling is necessarily a point-in-time sample, while fuel
content varies. As a result, asserts the commenter, by setting a standard based on a simple average, the
EPA could unnecessarily subject roughly half of all facilities to compliance penalties for using fuel with
the identical variability present during the performance tests - i.e., those for which the fuel sample was
taken from an above-average portion of the fuel. According to the commenter, instead of effectively
encouraging facilities to burn the most contaminated fuel they can during performance testing, the EPA
should grant facilities with low emissions a safety margin to reflect variability in fuel and operations.
The commenter suggests that the EPA specify that facilities may use fuel contaminants to set a percent
reduction for the system, and thus establish a fuel contaminant level (with adequate safety margin)
which facilities may use to comply without conducting periodic performance tests as frequently.

Comment 12: Commenters 17730 and 17800 believe the EPA should revise section 63.10008 to make
clear that the sampling and compositing procedures in Table 6 may be used. According to the
commenters, proposed section 63.10008 requires fuel analysis tests according to the "procedures in
paragraphs (b) through (e)" and Table 6, and paragraphs (c) and (d) specify minimum sampling
procedure and compositing procedures. However, assert the commenters, Table 6 also provides
sampling methods that can be used in lieu of those in paragraph (c) and some of those procedures
address compositing. For example, state the commenters, ASTM D2013, which the EPA proposes to

46


-------
require for "preparation of composited fuel samples," also contains procedures for "Preparation of
Composite Samples to Represent Lot-Size (or Consignment-Size) Quantities of Coal." The commenters
state the EPA should make clear that any procedure identified in Table 6 can be used in lieu of
procedures in paragraphs (c) and (d).

Comment 13: Commenter 17722 notes that section 63.10011 requires fuel samples to be collected and
analyzed during initial performance testing that "establishes maximum fuel pollutant input levels." The
commenter believes there is a very low probability that one composite coal sample will contain the
maximum concentration of every non-Hg HAP metal that could be expected while combusting coal -
even if that coal is from the same mine. Accordingly, the commenter believes it is impossible to
demonstrate compliance with section 63.10011. According to the commenter, a typical coal
specification sheet will provide the range, average, and standard deviation of the metals in the coal, and
it is not unusual for the standard deviation to be 10 to 15% of the average value.

Comment 14: Commenter 17881 notes that section 63.10008 requires the collection of three fuel
samples, which seems to be a one-time requirement, whereas the reference to section 63.10008 within
section 63.10011(c) would suggest that the provisions be used for on-going periodic sampling.

Comment 15: Commenter 19033 notes proposed regulation section 63.10008 and Table-6 requires fuel
sampling for non-Hg metals, regardless of whether or not the EGU operator elects to comply using the
PM emission limit. The commenter believes a more representative indicator of fuel content that will
impact PM emissions is ash content. In the event the EPA does not accept its recommendation that fuel
sampling only be required in the absence of CEMS, the commenter recommends that Table 6 be
amended to include an option to sample for ash content, if the EGU operator elects to comply using the
PM emission limit.

Comment 16: Commenter 19033 notes that proposed regulation section 63.10011 (b)(3) specifies that a
maximum non-Hg metals HAP input be established. According to the commenter, that requirement is
valid if the EGU operator elects to comply with the non-Hg metals HAP emission limit and does not
operate a PM CEMS. However, in the event the EPA does not accept its recommendation that fuel
sampling only be required in the absence of PM CEMS, the commenter believes the regulation should
allow establishment of maximum ash content, if the EGU operator elects to comply with the PM
emission limits. The commenter recommends that section 63.10011(b)(3) be amended as follows:

"If you elect to comply with the non-Hg HAP metal emission limits, jou must establish the
maximum non-Hg HAP metals fuel input level (HAP metal input) during the initial performance
testing using the procedures in paragraphs (c)(3)(i) through (iii) of this section. If you elect to
comply with the PM emission limits and do not operate a PM-CEMS, you must establish the
maximum ash content fuel input level during the initial performance testing using the
procedures in paragraphs (c)(3)(i) and (iii) of this section."

In this same connection, the commenter recommends that 63.10021(a)(2) be amended as follows:

(2) As specified in Sec. 63.10031(c), you must keep records of the type and amount of all fuels
burned in each EGU during the reporting period to demonstrate that all fuel types and mixtures of
fuels burned would either result in lower emissions of HC1, HF, S02, non-Hg HAP rnetals(//'j'ow
choose to comply with the non-Hg HAP metals emission limit), or Hg, than the applicable
emission limit for each pollutant (if you demonstrate compliance through fuel analysis and do not
operate a CEMS for the pollutant or surrogate), or result in lower fuel input of chlorine; fluorine,

47


-------
sulfur, non-Hg HAP metals (if you choose to comply with the non-HG HAP metals emission
limit), ash (if you choose to comply with the PM emission limit), or Hg than the maximum values
calculated during the last performance tests (if you demonstrate compliance through performance
stack testing).

Comment 17: Commenter 19121 believes the EPA is overly prescriptive concerning performance test
fuel sampling. Specifically, at section 63.10008(c) and (d), the commenter believes the EPA is not
recognizing other methods for collecting and preparing representative fuel samples. The commenter
states that ASTM has developed methods that utilize automated and continuous sampling systems, and
such equipment is present at many coal plants, and the systems are bias tested against ASTM standards.
The commenter also notes there are also ASTM approved sample preparation standards utilizing riffle,
grinding, and drying equipment designed to meet applicable ASTM methods.

4. Fuel sampling requirements for sources with CEMS.

Comment 18: Multiple commenters (17402, 17725, 17800, 17820 18014, 18498) believe that the EPA
did not intend to require sources using a CEMS to also conduct fuel sampling, but the EPA should
clarify this issue in the final rule.

Comment 19: Commenter 17402 requests that the EPA revise section 63.10007 to indicate that fuel
sampling is not required when the applicable HAP (or surrogates) are monitored using a CEMS. The
commenter requests that the EPA modify the rule to explicitly state that sources using CEMS for
compliance for a particular pollutant are exempt from all fuel sampling requirements for that pollutant.
According to the commenter, the text of the rule appears to indicate that fuel sampling requirements
apply only to those units that demonstrate compliance through "performance testing" for a particular
pollutant. The commenter states that as each unit must conduct initial "performance testing," this could
imply that facilities complying by using CEMS must also be required to carry out fuel analysis. The
commenter believes that the EPA did not intend to require sources using a CEMS to also conduct fuel
sampling, but the EPA should clarify this issue in the final rule.

Comment 20: Several commenters (17725, 17820, 18014, 18498) believe the fuel sampling
requirements for units using a CEMS to demonstrate compliance are unclear because of conflicting
language in the proposed rule. According to the commenters, the rule does not explicitly state that
sources using a CEMS for compliance for a particular pollutant are exempt from all fuel sampling
requirements for that pollutant. However, the commenters do not believe that the EPA intended to
require sources that demonstrate compliance via CEMS to also have to perform fuel sampling and
analysis. The commenters note that fuel sampling is certainly required for oil-fired sources that
demonstrate compliance through fuel analysis, and section 63.10011(b) specifies that sources that
demonstrate compliance through "performance testing" for a particular pollutant must also perform fuel
sampling to "establish maximum fuel pollutant input levels." According to the commenters, while not
formally defined, the rule generally implies that "performance testing" refers to emissions (stack)
testing. However, note the commenters, in section 63.10005(a) the EPA states that "performance
testing" may also consist of CEMS operating data, thereby creating ambiguity in whether other parts of
the rule that pertain to units using stack test data to comply also apply to those units using a CEMS for
compliance.

Comment 21: Commenter 17800 believes it is unclear from the way the regulation is written if EGUs
complying with CEMS systems must meet fuel input limits established during the performance testing.
The commenter cites section 63.10011(b), noting that since all EGUs are required to demonstrate initial

48


-------
compliance with each emission limit "through performance testing," and the proposed rule defines
"performance testing" to include the first 30 operating days of CEMS data, the proposal appears to
require that EGUs meet fuel input limits regardless of the "performance testing" option they choose.
According to the commenter, the proposal appears to require that EGUs meet operating limits for all
relevant control devices and load regardless of the "performance testing" option they choose.

Comment 22: Commenter 17758 notes that proposed section 63.10008 lays out in detail a fuel sampling
and analysis regimen; however, none of the fuel information is meaningful or relevant when either all of
the regulated HAP or their surrogates are continuously monitored. The commenter notes that proposed
section 63.10008(a) contains an "as applicable" clause, but its meaning is never explained.

Comment 23: Commenter 17881 suggests that section 63.10011(b)(2) not apply to units with Hg
CEMS (i.e., categorically all solid fuel-fired units, as these units are required to install Hg CEMS). The
commenter also believes the Hg content of coal may not correlate to the Hg emissions at the stack,
therefore trying to establish a maximum Hg fuel input level in the fuel prior to testing is not a good
indication of what will actually be emitted when utilizing the equations. According to the commenter,
for example, the form of the Hg emissions from coal combustion (i.e., elemental, oxidized and particle
bound) can have a major impact upon Hg emissions, as these forms are controlled to varying degrees by
prevalent control technologies. The commenter states that certain coals tend to favor elemental forms of
Hg emissions as opposed to oxidized forms of emissions. Thus, according to the commenter, you could
have a case where a coal with a high Hg content also results in a high percentage of Hg emissions in the
oxidized and particle bound forms. According to the commenter, such a coal may yield lower Hg stack
emissions than a coal with a lesser Hg content but that yields a much higher percentage of elemental Hg
emissions (as this form of Hg is not as readily removed in prevalent control technologies).

Comment 24: Commenter 18015 requests that the EPA clarify the applicability of the fuel analysis
requirements; specifically, the commenter recommends that the EPA state in the preamble and the final
rule that fuel analysis is not required for units that use CEMS to continuously comply with emission
standards. According to the commenter, should the EPA agree with the commenter's request to allow a
percent removal MACT standard approach (discussed separately), then the Hg content of the coal will
have to be determined in a routine manner.

Comment 25: Commenter 17881 believes it is not clear if the requirement contained in section
63.10021(a)(8) applies to solid fuel-fired EGUs which are demonstrating compliance with the PM
surrogate. The commenter believes that is should not apply, as a CEMS is installed to verify continuous
compliance, and that this paragraph makes little sense for units without PM CEMS that are required to
test monthly or bi-monthly; thus, the tests would already be conducted within the frequency (60 days)
specified in the paragraph.

5. Fuel sampling requirements for single-fuel units that comply with one or more standards based
on stack testing.

Comment 26: Commenters 17402 and 18498 believe that the EPA should allow facilities to conduct
more frequent fuel sampling to show continuing compliance based on their performance tests instead of
using CEMS.

Comment 27: Several commenters (17402, 17820, 18498) believe the rule is unclear as to whether units
that fire a single type of fuel are exempt from all fuel sampling and analysis requirements. According to
the commenters, the EPA appears to exempt units that fire a single fuel type from conducting fuel

49


-------
analysis as part of the initial compliance requirements in section 63.10005(c)(4). However, state the
commenters, in section 63.10011, the procedures used to establish the fuel operating limits include a
directive for handling single-fuel units. Despite these inconsistencies, the commenters believe that it was
probably the EPA's intention not to require single-fuel sources to conduct ongoing fuel sampling, and
thus the commenters propose fuel testing only be required every six months, unless a facility changes
fuel type. According to the commenters, this approach is consistent with the approach taken in the final
Industrial Boiler MACT rule, which did not require any ongoing fuel testing. The commenters note that
the EPA explicitly states in the definition of "fuel type" in section 63.10042 that changes in vendors for
a particular fuel type are not considered a change in fuel type, and assert that this indicates a belief that
fuel sampling is not required within fuel types. According to the commenters, the EPA should clarify the
fuel sampling requirements for single-fuel units that comply with one or more standards based on stack
testing.

Comment 28: Commenters 17725 and 17820 note that for units firing a single fuel type, fuel sampling
and analysis is not required for supplemental fuels used only for startup, shutdown or for maintaining
flame stability (section 63.1 0005(c)(5)) According to the commenters, this exemption does not appear
to apply to units that fire multiple fuel types or blends, and they request that the EPA clarify this
exemption in the final rule.

Comment 29: Commenter 17722 requests that EPA clarify that fuel testing is not required for sources
that combust a single fuel, excluding limited secondary fuel use for startup, shutdown or flame
stabilization. The commenter believes single-fuel plants should be exempt from the requirements under
section 63.10007(c) which states "you must conduct the performance tests at the maximum normal
operating load while burning the type of fuel or mixture of fuels that has the highest content of chlorine,
fluorine, non-Hg HAP metals, and Hg, and you must demonstrate initial compliance and establish your
operating limits based on these tests."

Comment 30: Commenter 17775 recommends the EPA clarify or remove the operating limit
requirements, and clarify the fuel analysis requirements for single fuel EGUs and supplemental fuels.

6. Low emitting EGUs.

Comment 31: Several commenters (17402, 17754, 17808) believe the LEE monitoring requirements are
overly burdensome. Commenter 17808 believes in many cases, monthly fuel testing would be redundant
as this requirement would result in the repetitive testing of the same fuel shipment (see further
discussion below in the context of oil-fired units). Commenter 17402 believes the monthly sampling
requirements are arbitrary as there is no requirement in the rule to establish a fuel operating limit.
Further, although fuel changes are addressed in the preamble, they are not directly addressed with regard
to LEEs in the rule itself. For LEE single fuel facilities, Commenter 17402 believes that fuel sampling
should only be required every six months, or on a change of fuel. Further, Commenter 17402 believes
that if any increases in concentration are small enough that based on the facility's demonstrated
contaminant reduction performance on the prior stack test they would not cause the LEE limit to be met,
then retesting of performance should not be required.

Comment 32: Commenter 17775 states that if EPA intended to require that LEEs perform monthly fuel
analysis under section 63.10006(c), the EPA needs to make clear that compliance with the maximum
fuel input levels is not required and explain why it chose monthly testing. According to the commenter,
analyzing fuel monthly when the fuel supply or mixture has not changed seems unnecessary. The
commenter states that if the EPA intended to require that LEEs establish and comply with maximum

50


-------
fuel input levels as an "operating limit" under section 63.10011(b), rather than perform monthly fuel
analysis, the EPA needs to explain that the fuel analysis is an operating limit and not a demonstration of
compliance using fuel analysis under section 63.10011(c). According to the commenter, the EPA also
needs to remove the monthly fuel sampling and analysis requirement in section 63.10006(c). If the EPA
intended to require that LEEs establish and comply with operating limits other than maximum fuel input
levels, the commenter states, the EPA needs to issue a proposal that explains the purpose of those limits
and how they apply.

Comment 33: Several commenters (17725, 17820, 18498) believe the fuel sampling requirements for
LEE units are ambiguous and provide no compliance value since the rule does not require the
establishment of a fuel input operating limit. According to the commenters,, the requirements do not
address single-fuel units, changes in fuel type, or units that burn or co-fire multiple fuels. The
commenters assert that presumably, LEE units would follow an analogous procedure as non-LEE units
and reassess the ability to meet LEE status based on the new fuel type/blend; this would require sources
that burn multiple fuel types or blends to establish a fuel-input operating limit during the initial
compliance demonstration. Consistent with the non-LEE requirements, the commenter suggests the EPA
remove the arbitrary monthly sampling requirement and allow sources to conduct fuel sampling only
when there is a change in the fuel type. For single-fuel units, the commenters suggest the EPA specify
that these units are not required to comply with any of the fuel sampling requirements.

Comment 34: Commenter 17754 suggests that to the extent that the EPA does not revise the proposed
rule to allow LEE units to demonstrate continuous compliance through annual performance testing only,
rather than monthly fuel evaluations, and instead insists upon requiring that all LEEs demonstrate
continuous compliance using a fuel factor based approach, the EPA should nonetheless revise the
specific fuel factor based approach currently required under the proposed rule. The commenter believes
the requirement to use the 90th percentile confidence level to determine the operating limit for Hg is
improper, because the use of such value could cause a LEE to lose its LEE status, even though the unit's
actual Hg emissions remain substantially below the LEE thresholds.

Comment 35: Several commenters (19536, 19537, 19538) believe the EPA should discard its "Low
Emitting Units" monitoring protocols. The unavoidable variability claimed by the EPA, moreover,
indicates that plant emissions range as much as 50 times higher than the results of a three-run test. As a
result a plant with test data at 50% of the proposed standard will likely - indeed, almost certainly -
exceed the prescribed limit during its operations. Yet the only compliance monitoring required for an
LEE is an initial performance test, and subsequent check-up performance tests every 5 years, coupled
with monthly fuel sampling. That monitoring provides no assurance of continuous low-HAP emissions.
Fuel sampling would reveal no information about HCN, which is a byproduct of combustion and cannot
be inferred from fuel sampling. Further, fuel sampling would disclose no information about HAP that
did not originate in the fuel. Additives, such as PVC, are sometimes blended with the fuel to facilitate
Hg control. Metals are present in the reagents (limestone, lime) and water used in scrubbers. Metals are
also released from the boiler, duct work, and control systems. These would not be detected by fuel
sampling.

Comment 36: Commenter 17808 recommends that for non-Hg HAP as well, owners/operators of a LEE
unit have the option to conduct an annual performance test to demonstrate that emissions are less than
50 percent of the relevant emissions standard. The commenter notes that the EPA proposes that for all
other HAP, LEEs would demonstrate continuous compliance and maintain LEE status through monthly
fuel analysis as well as performance (stack) testing every 5 years. However, in many cases, according to

51


-------
the commenter, monthly fuel testing would be redundant as this requirement would result in the
repetitive testing of the same fuel shipment.

Comment 37: Commenter 17807 suggests the EPA reconsider the use of fuel samples as the method of
compliance for the maintenance of LEE status and alternatively suggests using the fuel samples as a
control similar to the intent of the EPA; however, the compliance should be based on a 12-month rolling
average of the key parameters in the fuel. According to the commenter, if the 12-month rolling average
of fuel samples shows a monitored parameter over the threshold then a stack test would be triggered.

This procedure would ensure that only an actual emissions exceedance could cause a unit's LEE status
to be lost.

7. Liquid oil-based EGUs.

Comment 38: Several commenters (17758, 17775, 18428) suggest the alternative fuel analysis
provisions should apply to all affected liquid oil-based EGUs. One commenter cites the summary of the
rule proposal 76 FR 25031, in which the EPA states that this provision applies only to limited-use oil
units and not other affected oil units. The commenter explains that the provisions of the proposed rule
itself (sections 63.10005(c) and 63.10006(s)) appear to indicate that owners/operators of all affected
liquid oil-fired units may perform fuel analyses to demonstrate initial and continuous compliance with
applicable emission limitations, as an alternative to performance stack testing. The commenter requests
that the final rule clarify that the alternative to use fuel testing to demonstrate initial and continuous
compliance applies to all affected liquid oil-fired EGUs, not only limited-use units. Commenter 17775
also requests that the EPA further explain its preamble statements in order to allow meaningful comment
on that procedure.

Comment 39: Commenters 17386 and 17621 believe the fuel oil metals analysis methods are not
sensitive enough to support compliance monitoring for limited use oil EGUs. Commenter 17386 states
that based on contacts with a number U.S. laboratories, standard available analytic techniques are not
capable of achieving the detection limits required to demonstrate compliance with proposed MACT
emission limits for certain HAP Metals (such as cadmium, beryllium and antimony) in liquid fuel oils.
The commenter states the fuel oil concentration for cadmium, beryllium and antimony would have to be
< 5 ppb to demonstrate compliance with MACT limits, and none of the laboratories contacted could
achieve this detection level.

Comment 40: Commenter 17386 notes the detection limits of the analytical methods for non-Hg metals
in oil are too high to support compliance verification. According to the commenter, in the ICR Part III
database, most of the fuel oil metal concentrations are non-detect values, with detection limits ranging
from 0.25 to 10 parts per million by weight (ppmw). The commenter states that this range is equivalent
to approximately 10-6 to 10-4 lb/MMBtu, while the proposed MACT metal emission limits for existing
oil-fired units range from 10-7 to 10-6 lb/MMBtu. The commenter states that fuel samples from several
oil-fired EGUs were analyzed with ASTM D6357, the method specified in the ICR for coal, not oil, and
that this method gave lower detection limits, on the order of 0.01 ppmw, or approximately 10-7
lb/MMBtu. According to the commenter, the use of ASTM D6357 for oil samples may give inaccurate
results for metals because the ashing step that works well for coal can cause the loss of metals in oil
samples, resulting in erroneously low metal concentrations. The commenter asserts that fuel oil metals
concentrations would need to be quantifiable below 0.01 ppmw to demonstrate compliance. According
to the commenter, the analytical techniques currently used for fuel oil samples by most laboratories
cannot measure accurately at those levels. The commenter suggests allowing fuel oil monitoring to be

52


-------
used as a compliance method for limited-use EGUs, a new or improved standard certified method for
fuel oil will be required.

Comment 41: Commenter 17718 suggests the EPA should clarify whether the fuel analyses and
procedures in the proposed regulatory language (40 CFR section 63.10008) are only applicable to liquid
oil-fired EGUs that desire to meet their applicable emission limits through fuel sampling.

Comment 42: Commenter 17760 suggests the EPA should clarify that all liquid oil-fired units may
demonstrate compliance through fuel analysis. The commenter believes the language in the preamble to
the proposed rule and the proposed regulatory language are inconsistent regarding the availability of the
fuel analysis option. The commenter believes the preamble seems to limit the option to limited-use
liquid oil-fired units, citing 76 FR 25031, while the regulatory language seems to allow all affected
liquid oil-fired units to utilize the fuel analysis option, citing 40 CFR 63.10000.

Comment 43: Commenter 17796 suggests the requirements for liquid oil-fired units are confusing and
should be rewritten for clarity. The commenter cites "What Are My General Requirements/or
Complying with this Subpart", paragraph (c)(2), which states that liquid oil-fired EGUs can demonstrate
initial and continuous compliance using fuel analysis, noting that these general requirements are
contradicted in section 63.10006, which specifies different continuous compliance methods for liquid
oil-fired units.

Comment 44: Commenter 17718 suggests that within the proposed regulatory language (40 CFR
section 63.10011(b)), where reference is made to conducting fuel analyses and establishing maximum
fuel pollutant input levels ".. .as applicable", the EPA should clarify that the fuel sampling, analyses, and
maximum input levels are only applicable to liquid oil-fired EGUs that choose to meet their emission
limits through fuel sampling methodologies. The commenter believes the establishment of fuel limits
appears applicable only to facilities that choose to comply via fuel analysis. The commenter believes if
facilities apply CEMS, accurate compliance can be determined at the emission point and, therefore, the
fuel input becomes irrelevant. The commenter also states that there are numerous inaccurate
section/paragraph references within the proposed regulatory language of 40 CFR section 63.10011(b).
The commenter suggests the EPA carefully review this section to properly link references to the
appropriate sections and paragraphs.

8. Monthly fuel analysis.

Comment 45: Several commenters (17386, 17758, 17760, 17902) believe the monthly fuel analysis
contained in section 63.10006(s) would be unnecessarily burdensome, costly and impractical. One
commenter suggests requiring fuel analysis to be performed on each shipment of oil received should be
adequate to demonstrate compliance. Commenter 17760 notes that oil-fired plants require verification
that fuel oil meets certain specification prior to accepting a delivery and after a plant accepts a shipment
of fuel oil and places it in a storage tank and that it is highly unlikely that the composition of the fuel oil
will change. Commenter 17386 notes that for large fuel oil storage tanks which receive oil deliveries
less frequently than monthly the requirement is unjustified and proposes fuel sampling for oil-fired units
shall be performed quarterly only during periods when fuel oil replenishment has been made to the fuel
oil storage tank. Commenter 17902 recommends that this requirement be revised to require sampling
only when there is a fuel switch, new fuel, fuel shipment, or change in fuel source. In addition, this
commenter suggests the final rule should allow use of fuel supplier data for each shipment as an
alternative approach.

53


-------
Comment 46: Commenter 17731 suggests the EPA remove the requirement that EGUs without control
devices conduct HC1 emission testing every month, 76 FR 25029/3, for units that otherwise meet the
HAP emission limits. The commenter believes this burdensome requirement offers no environmental
benefit because compliant emission levels can be explained by fuel sources. The commenter suggests a
better alternative would be yearly stack testing with a monthly fuel sampling.

Comment 47: Commenter 17807 notes that although they prefer that SO2 be used as a surrogate, they
do not object to allowing utilities to opt to perform routine HC1 testing or continuous emission
monitoring. The commenter requests that the EPA allow utilities to choose to demonstrate compliance
for HC1 through routine fuel sampling. According to the commenter, most facilities currently utilize
some type of fuel sampling methodology to test their fuels burned, and the chloride content can be
analyzed using ASTM 4208/300 along with existing fuel test methods. The commenter notes that
facilities will need to establish an upper chloride threshold in the fuel as demonstrated by HC1 stack
testing and that once the limit is established, the daily or weekly chloride analyses on a 30-day rolling
average will demonstrate compliance provided the threshold is not exceeded. The commenter believes
this will provide an established procedure to ensure compliance.

9. Site-specific fuel analysis plans.

Comment 48: Commenters 17775 and 17800 state that although the commenters do not object to a
requirement to submit a plan or to use standardized procedures, as required by section 63.10008;
however, because there is so much diversity in how fuel is received, stored, and processed at individual
facilities, the commenters assert that the EPA needs to allow more flexible procedures to accomplish the
primary objective.

Comment 49: Commenters 17775 and 17800 discuss that under proposed section 63.10008(b)(1), the
proposed plan must be submitted to the Administrator at least 60 days before the fuel analysis. Because
some of the information required to be included may change from analysis to analysis, the commenter
assumes the EPA intends sources to submit a new plan or update the existing approved plan if
information changes. For example, the commenter notes, the plan must include identification of all fuel
types anticipated to be combusted and whether the source or fuel supplier will conduct the analysis.
Proposed section 63.10008(b)(2). According to the commenter, although it might be possible to submit
that information 60 days in advance of the initial demonstration and receive approval before conducting
the analysis, it may not be possible for subsequent analysis in response to changes in fuel type or fuel
mixtures (since those might occur with less notice or planning). According to the commenter, the
requirement to submit a new or revised plan also makes little sense if monthly analysis is required. The
commenter requests that the EPA either remove the requirement for advance submittal and approval of a
plan after the initial compliance demonstration, or remove the requirement to include in the plan
information that might change.

Comment 50: Commenter 17821 does not object to the requirement to develop a site-specific fuel
analysis plan and does not object to submitting it to the EPA; however, the commenter sees little value
in the requirement that the EPA must approve the plan before it can be implemented. The commenter
believes that the requirements for development of the plan are specified in the proposed rules and
sources are fully capable of following and implementing those requirements. The commenter notes there
will be hundreds of fuel analysis plans submitted to permitting agencies and the EPA in a very short
period of time which can result in a backlog of plans to be reviewed, which could easily mean that a
source submitting a plan before the 60-day deadline in advance of testing may not receive approval to
use the plan before it must conduct that testing. The commenter notes that if the delay is extensive, this

54


-------
could mean that a source might not be able to complete performance testing before the deadlines
specified in the rules. The commenter therefore urges the EPA to modify this section of the proposed
rule to eliminate the requirement for the EPA to approve fuel analysis plans prior to conducting testing.

Comment 51: Commenter 17881 notes that section 63.1008, requiring development of a site specific
fuel analysis plan, as applicable, is very unclear how to determine if you need a fuel analysis plan as
section 63.10005 does not stipulate which units are required to conduct fuel analysis on an on-going
basis. Provision (b)(2)(iv) requires that the minimum expected detection level for chlorine, fluorine, Hg,
and metals be included in the plan. The commenter notes that the EPA should clarify that fluorine is
only applicable for oils. The commenter advocates that the EPA provide guidance on required minimum
detection levels for these parameters.

10. Performance testing and fuel analysis.

Comment 52: Commenter 17775 cites proposed section 63.10011(b) that "if you demonstrate
compliance through performance testing, . . . [y]ou must also conduct fuel analysis according to §
63.10008 and establish maximum fuel pollutant input levels according to paragraphs (c)(1) through (5)."
(The commenter notes that Table 8 actually refers to section 63.10011(c) and (d), but the EPA probably
intended to reference (b) and (c).) According to the commenter, table 8 also requires EGUs to continue
combusting only the fuel types and mixtures used to demonstrate compliance with fuel input levels
under section 63.10011(b) and (c). The commenter states that accordingly, any unit that demonstrates
compliance using "performance testing" would, under Table 8, be limited to combusting only those fuels
or mixtures used during initial performance testing.

Comment 53: Commenter 19033 suggests the EPA clarify the meaning of "highest content" contained
in 63.10007(c). The commenter cites an EGU operated which is a coal-fired unit with natural gas firing
capability during periods of start-up; however, the coal burned in this EGU comes from more than
one mine source. The commenter notes that it will make a good faith effort to identify the coal that has
the maximum anticipated amount of chlorine, and Hg, and base its tests on that coal; however, it will be
unable to certify that coal from another section of the mine will not have higher chlorine or Hg content
than what was tested, due to the variable nature of coal. The commenter also notes it may also be
possible that a coal with a maximum chlorine content may not be the coal that also has the maximum
mercury content.

Comment 54: Commenter 18447 questions the EPA statement in the preamble of the proposed rule that
"For units without wet or dry FGD scrubbers that must comply with an HC1 emission limit, you must
measure the average chlorine content level in the input fuel(s) during the HC1 performance test. This is
your maximum chlorine input operating limit." The commenter believes that this means that once the
HC1 performance test has been completed and the chlorine results are known, the fuel that was used
during the test cannot be used again. According to the commenter, this is because the fuel's measured
average chlorine value now becomes the maximum chlorine limit; the fuel that created the maximum
chlorine limit (by virtue of its average) will now exceed the maximum limit 50% of the time (by virtue
of the normal distribution curve) and therefore cannot be used again. The commenter believes as written,
it creates a possible incentive to test with a fuel with a high chlorine content, and then switch back to a
fuel with a lower chlorine content, whose maximum chlorine content is less than test fuel's average
chlorine content.

Comment 55: Commenter 19033 suggests that the EPA clarify section 63.10007(c) with respect to the
requirement that coal which has the highest non-Hg metals must be tested, especially if the EGU

55


-------
operator elects to comply using the PM emissions limit, which is a surrogate for non-Hg metals. The
commenter suggests that the phrase in question be amended, as follows:

"You must conduct performance tests at the maximum normal operating load while burning the
type of fuel or mixture of fuels that has the highest content-of chlorine, . fluorine, non-Hg HAP
metals (if you elect to comply with the non-HG metals HAP emission limitation), and Hg, and

you must demonstrate initial compliance and establish your operating limits based on these tests."

11.	Continuous compliance.

Comment 56: Commenter 17881 suggests the provisions of section 63.10021(a)(2) should state that
fuels used for start-up/shutdown and flame stabilization are exempted from this requirement. Also,
according to the commenter, it is the fraction of heat input which is relevant to meeting the emission
limit, not the overall fuel mass (based on the HAP input calculations at section 63.10011). According to
the commenter, the requirement to keep records of the amount of fuel burned in each EGU is not
relevant to any compliance requirement in the rule, and the utility industry already reports fuel usage to
the Department of Energy, Energy Information Administration in various reports. The commenter notes
that this information is available for the EPA to access.

Comment 57: Commenter 17881 suggests that with respect to section 63.10021(a)(5), if the EPA allows
actual sampling vs. theoretical results, then these provisions would not apply as direct sampling would
be used to demonstrate compliance. The commenter believes the monthly compliance demonstration
through fuel analysis is all that is required to comply with the Hg emission limit instead of trying to
theoretically pre-qualify a fuel.

Comment 58: Commenter 17781 suggests that with respect to 63.10021(a)(3), if the EPA allows actual
sampling versus theoretical calculated results, then the provisions of this paragraph would not apply as
direct sampling would be used to demonstrate compliance. The commenter believes the EPA should
leave it up to the facility to demonstrate compliance, as it does not make sense to try and pre-qualify
emissions. According to the commenter, the logistics of trying to pre-qualify a fuel does not work in the
real world, as what is sampled for the pre-qualification analysis is most likely not what is really burned,
as oil is blended in a storage tank prior to burning; the onus of proof of compliance is on the facility.

12.	Chloride concentration variability.

Comment 59: Commenters 17816 and 19114 note HC1 CEMS currently are not commercially available
or adequate for in-stack measurements at coal-based EGU's, and are not anticipated to be available by
the compliance date of the rule. As a result, according to the commenters, sources will be forced to
either take a fuel limit or an operating parameter limit. The commenters believe the fuel analysis limit is
impractical because of the inherent variability of chloride concentrations in coal, both between various
ranks of coal and within the same coal category. According to the commenters, it will be impossible to
control fuel deliveries in such a manner as to negate the possibility of burning coal with chlorine content
above that which was used during compliance testing.

13.	Stop belt sampling (section 63.10008(c)(l)(i)).

Comment 60: Commenters 17715 and 19114 suggest the EPA remove the provisions for affected
sources to conduct stop belt sampling or to pull samples from the coal piles during testing. The
commenters believe stop belt sampling is neither safe to conduct due to stored energy in the conveyor

56


-------
belts, nor is it representative of a unit's operation. According to the commenters, a unit may have to
reduce process rate due to a decrease or a lag in the time that the fuel is being delivered. The
commenters assert that sampling from the coal pile will not gather coal samples that are representative
of what is being burned. The commenters note they have coal piles that are greater than 15 acres in area
and gathering five samples uniformly spaced at a depth of 18 inches will not adequately represent what
is being burned during the test period.

Comment 61: Commenter 17722 notes that stopping and starting a coal belt that is moving tons of coal
is problematic and labor intensive. According to the commenter, the sampling procedures are applied to
screw conveyors, and the commenter believes it is impossible to withdraw a six-inch wide cross section
from a screw conveyor because of the auger system.

Comment 62: Commenters 17722 and 19114 suggest the EPA should allow the EGU operator to
determine the best available method to collect a representative sample. Commenter 19114 suggests that
the EPA specify a number of representative fuel samples during the testing.

Comment 63: Commenter 17800 believes the proposed stop belt sampling requirements for collecting
composite fuel samples is not reasonable and apparently would not allow for the use of continuous belt
samplers. According to the commenter, in addition, many belts cannot be restarted with coal on them
because the belt is too heavy for the motor to start. The commenter asserts that for sampling piles or
trucks, the rule requires (among other things) use of a "square shovel," collection of samples at a depth
of exactly "18 inches," collection at five locations "uniformly spaced over the surface of the pile," and
breaking of pieces larger that exactly 3 inches (citing proposed section 63.10008(c)(2)(ii) and (d)). The
commenter believes representative samples can be taken with shovels of other shapes, at depths greater
or less than 18 inches, and without measuring the actual size of individual coal pieces. The commenter
requests that the EPA remove the prohibition on moving belt samplers and reexamine and moderate the
pile sampling requirements to provide more realistic criteria (e.g., use the same shovel for all samples,
collect samples at a uniform depth of approximately 18 inches, and break apart large pieces (e.g., pieces
greater than 3 inches).

Comment 64: Commenter 17881 expresses concern over sampling from a belt, as there are significant
safety risks with reaching across a belt. The commenter asserts that according to safety requirements, the
belt would have to be locked out and tagged out in order to cross the vertical plane of a belt. According
to the commenter, plant personnel currently collect coal samples from a feeder chute just prior to the
coal mill, and the commenter suggests the EPA should consider other sampling alternatives to those
currently presented in section 63.10008(c).

Comment 65: Commenter 18015 believes the EPA requirement of stopping the coal belt to take coal
samples in a swath across the belt is unnecessary and can create operating problems. According to the
commenter, every time a coal belt is stopped, a risk is incurred, however slight, of having difficulty
restarting the belt, and it is possible to get good representative samples without stopping the coal belt.
According to the commenter, EGUs have been following such practices successfully for many years.
The commenter believes the EPA should eliminate the requirement to stop the coal belt to take samples.

Comment 66: Commenter 19121 believes requiring belt stop and starts during plant operation is
dangerous, logistically and operationally intrusive, and unnecessary.

14. Coal sampling methods.

57


-------
Comment 67: Commenter 17821 objects to the requirement of a manual coal fuel-sampling method as
proposed in section 63.10008(c), (c)(l)-(2). The commenter notes they utilize automated mechanical
coal sampling systems that are operated under procedures such as those described in ASTM D2013.
According to the commenter, these automated methods are widely accepted and do not require the labor-
intensive and time-consuming procedures described in the above referenced sections of the proposal.
The commenter believes the EPA should allow the use of automated sampling procedures that follow
standard practices referenced in appropriate ASTM or other such methods that are written by experts in
their fields and are peer reviewed. In other rulemakings, the EPA has referenced ASTM standard
practices. The commenter suggests these rules should allow the use of those standards and should not
require a manual method of sampling.

Comment 68: Commenter 17821 strongly urges the EPA to avoid writing detailed sample preparation
procedures as specified in section 63.10008 (d), (d)(l)-(7). In lieu of the agency writing their own
procedures, the commenter believes the proposal should reference appropriate ASTM standards that are
widely used by the utility industry, and others and such sample preparation methods that are written by
experts in their fields and are peer reviewed. The commenter notes that in other rulemakings, the EPA
has referenced ASTM standard practices. According to the commenter, these rules should allow the use
of those standards and the EPA should not take on the challenge of writing special procedures that are
unique to this rulemaking.

15. Other comments.

Comment 69: Commenter 17725 notes that the EPA defines the two coal-fired unit subcategories as
based on 1) the calorific value of the coal the boiler is designed to combust and 2) the boiler dimensions
in terms of height-to-depth ratio. According to the commenter, the larger boiler dimensions are a result
of the inherently higher mineral matter of these fuels. The commenter states that there are two issues that
warrant clarification so that compliance requirements are easily determined and understood: First, many,
if not most lignite units burn a blend of coals, e.g., lignite and PRB; and second, the industry standard
for determining heating value of as-received coal is based on an ultimate/proximate analysis. According
to the commenter, clarification is needed from the EPA regarding their reliance on the moist mineral
matter free heating value (ASTM D388) of coal. The commenter states that this method is typically
relied upon to classify distinct coal regions and individual seams don't vary significantly within a
region. According to the commenter, the ASTM D388 method specifically excludes any samples of
weathered or oxidized coal be used for coal rank classification and further requires no less than three
samples to be taken within the same mine or locality of the coal bed in accordance with U.S. Bureau of
Mines sampling methods.

Comment 70: Commenter 17725 suggests the EPA remove redundant stack test requirements. The
commenter notes that the EPA has established alternative limits for compliance for various HAP groups
and these options provide the sources with a measure of flexibility. However, the commenter believes
the EPA is requiring stack tests for both the pollutant and surrogate. According to the commenter, since
limits for each pollutant (or surrogate) have been independently established to assure effective
reductions in accordance with section 112 of the CAA, the commenter believes there is no need to test
for both the pollutant and surrogate. The commenter believes a performance test should only be required
for the pollutants and surrogates with which the source is choosing to show compliance (e.g., if a source
is demonstrating compliance for acid gas HAP using SO2, it should not be required to conduct a HC1
performance test) and suggests the extra tests are superfluous since the surrogacy has already been
established.

58


-------
Comment 71: Commenter 17881 discusses issues with Table 6 - Fuel Analysis Requirements, noting
that this requirement stipulates the use of Method 19 fuel factor (F-factor) methodology to convert
emission concentrations into units of lb/MMBtu. According to the commenter, Method 19 does not
contain procedures for converting any constituent other than sulfur percent by weight into an equivalent
pollutant emission rate on an energy input basis. Furthermore, states the commenter, it is wholly unclear
how one would convent a fuel constituent concentration into units of lb/MWh, as such a conversion
would not be based on just the fuel characteristics (i.e., constituent concentration and heating value) but
would instead also relate to the heat rate of the unit in which the fuel is to be combusted. The commenter
suggests the EPA should either remove the reference to converting the concentration to units of
lb/MWh, or should provide clear procedures for conducting the associated calculation(s).

Comment 72: Commenter 18025 recommends the EPA set a percent water content limit for oil, rather
than setting HC1 and HF emissions limits for liquid oil-fired EGUs. The commenter notes ASTM test
methods are available for measuring the percent water content of fuel oil (D95 and D473). The
commenter suggests that plant operators would test each shipment received to ensure compliance with
the proposed limit.

Comment 73: Commenter 18483 suggests that should such IGCC or other generating units remain
subject to the rule, fuel sampling should be allowed as a sole compliance demonstration option in lieu of
a Hg CEMS or sorbent trap methodology due to Hg being removed from the fuel prior to combustion
and the lack of post-combustion controls.

Comment 74: Commenter 19114 notes that IGCC processes are inherently different from other methods
of coal-based electric generation and more similar to natural gas combined cycle units in terms of design
and emissions. According to the commenter, if IGCC units are not exempted in the final rule, then the
standards should be revised to address the unique characteristics of IGCC processes. The commenter
believes that issues that would need to be addressed include: the applicability of fuel sampling
requirements, gasifier feedstock sampling, raw syngas sampling, clean syngas sampling, syngas fired in
the combustion turbines, syngas fired in a flare, processed syngas fired in thermal oxidizer, etc.

Comment 75: Commenter 17775 notes concerns with applicability with provisions and paragraphs cited
in section 63.10011(b). With respect to operating limits, the commenter believes proposed section
63.10007 does not discuss applicability at all. According to the commenter, with the exception of the
filterable PM limit applicable to units using PM CEMS, Table 7 also does not distinguish between
compliance options. Instead, states the commenter, Table 7 refers to various parameters depending on
which control device "your operating limits are based on" (citing section 63.10011(b)(6)). (The
commenter notes that although the rule actually cites section 63.10011(c)(6), that provision addresses
fuel sampling, not operating limits. As a result, the EPA probably intended to reference (b)(6).)
According to the commenter, Table 7 also refers only to specific control devices and not compliance
options. With respect to fuel input levels, the commenter asserts that paragraphs (c)(1) through (5)
specify how fuel input levels are established but do not identify which EGUs must establish them. The
commenter notes that proposed section 63.10008 requires "performance fuel analysis tests" "as
applicable"; Table 6 requires fuel analysis "as stated in section 63.10008"; and proposed section
63.10031 requires compliance reports to address compliance with fuel input limits "for sources that
demonstrate compliance through performance testing."

Comment 76: Commenter 17801 notes on page 25037 of the proposal the EPA provides an option to
monitor inlet chlorine, fluorine, non-Hg metals and Hg in liquid oil to meet outlet emission rate limits,
noting that it is reasonable to do so because oil-fired units remove these fuel-borne HAP from the oil

59


-------
before combustion in lieu of installing air pollution control devices (APCD). In response to the EPA's
request for comment on the viability of this approach for IGCC, the commenter agrees that fuel
monitoring (of the syngas) should be an option for IGCC as well based on the same reasoning as to that
fuel "clean-up" vs. APCD. The commenter believes fuel sampling should be allowed as a sole
compliance demonstration option for IGCC in lieu of a Hg CEMS due to Hg being removed from the
fuel prior to combustion and the absence of post-combustion controls in lieu of pre-combustion control.

Response to Comments 1-76: Based on the comments received and a further review of the technical
challenges associated with the proposed fuel analysis requirements, the EPA has not finalized the
proposed fuel analysis requirements. Fuel analysis of moisture for certain liquid oil-fired units remains a
compliance assurance option. As the rule no longer requires operating limits for pollutants based on fuel
content or fuel analysis, the comments summarized above are largely moot. For low emitting EGUs, the
agency agrees that the proposed LEE ongoing eligibility requirements were overly burdensome and
restrictive. As a result, existing solid- or liquid-fired units that qualify for LEE status for Hg will be
required to conduct a 30-day test for Hg using Method 30B each year. Neither fuel analysis nor
adherence to an operating limit will be required. Should an annual test show ineligibility for LEE status,
the unit would revert to the requirements for Hg monitoring using CEMS or sorbent traps or quarterly
emissions testing. For other pollutants, a unit can qualify for LEE for an applicable pollutant if all
performance tests over a 3-year period demonstrate that the unit remains below 50% of the emission
limit for the applicable pollutant. Under those circumstances, the unit would qualify for emissions
testing of that pollutant every 3 years to demonstrate ongoing compliance with the rule.

The only fuel analysis provision in the final rule is an optional compliance assurance method for liquid
oil-fired units. If you combust liquid fuels, if you wish to demonstrate ongoing compliance with HC1 and
HF emissions limits by measuring fuel moisture content, and if your fuel moisture content is no greater
than 1.0 percent, you must measure fuel moisture content of each shipment of fuel if your fuel arrives on
a batch basis; or measure fuel moisture content daily if your fuel arrives on a continuous basis; or obtain
and maintain a fuel moisture certification from your fuel supplier. Should the moisture in your liquid
fuel be more than 1.0 percent, you must either: (1) conduct HC1 and HF emissions testing quarterly and
develop a site-specific monitoring plan to monitor appropriate operating parameters to ensure that
operations remain consistent with those present during performance testing; or (2) use an HC1 CEMS
and/or HF CEMS.

60


-------
5A04 - Testing/Monitoring: Detection levels

Commenters: 17316, 17386, 17621, 17622, 17711, 17715, 17725, 17730, 17775, 17790, 17800, 17821,
17873, 17902, 17914, 18034, 18429, 18443, 18498, 18023

1. Analytical techniques and detection levels.

Comment 1: Commenters 17316 and 17386 state that based on contacts with a number of laboratories,
it appears that standard available analytic techniques are not capable of achieving the detection limits
required to demonstrate compliance with proposed MACT emission limits for certain metals, such as
cadmium, beryllium and antimony, at least in oil. Commenter 17316 refers to a Table (note: this table is
not attached to the comment), that allegedly addresses the concentration in oil for each regulated HAP
metal corresponding to proposed MACT emission limits for oil fired EGUs. According to the
commenter, for cadmium, beryllium and antimony, the concentration in oil would have to be < 5 ppb to
demonstrate compliance with MACT limits, and according to the commenter, none of the laboratories
contacted could achieve this detection level. Moreover, the commenter questions the accuracy of
analysis results determined by the specialized methods used to reach the detection levels required for
such a compliance demonstration on fuel oil.

Response to Comment 1: The requirements for fuel sampling and analysis for the listed metals have
been removed from the final rule.

Comment 2: Commenter 17622 states that based on information provided in the proposed rule, they
cannot validate that technology exist to accurately measure the proposed emission limits for new units.
The commenter states monitoring systems have to be capable of accurately measuring emissions below
the limits established by the EPA and in practice emission control technologies must be able to provide
long term control at emission levels below the proposed limits. The commenter notes that when the EPA
sets an emission limit, all EGUs establish operating levels below the EPA or permit levels, to some
extent, to compensate for operational variability, fuel changes, and startup and shut down times that
occur during normal plant operations, and in order to remain in compliance over the averaging period.
Therefore, according to the commenter, emission limits need to be established within the capabilities
and accuracy of monitoring systems, and when owners/operators purchase control equipment, they may
add an operational margin in their specification and request for performance guarantees. The commenter
believes compliance monitoring and measurement for the proposed new unit emission limits are of
concern, and vendor guarantees may be problematic without the ability to consistently measure
remaining pollutants at the low emission levels proposed.

Response to Comment 2: As more thoroughly discussed in 4A03 of this document, the new source
limits have been revised in order to represent the representative detection level (RDL) instead of the
MDL determined by a single source.

Comment 3: Commenter 18429 believes the EPA's proposed test methods are not adequate for the
excessively low limits for new sources, including both Hg and HC1 CEMS. The commenter references
EPRI analyses. The commenter suggests the EPA complete a re-review of the limits and test methods
for new units to provide a meaningful MACT with which new units can continuously comply. The
commenter notes that consistent with CAA section 112(d), the emission limits must be measurable by
current technology.

61


-------
Response to Comment 3: In response to comments, the final rule allows the option to perform periodic
stack measurement or monitoring for PM, HC1, HF, and non-Hg HAP metals. There is discussion
elsewhere in this document of how the agency managed BDL data in analyzing the floor and developing
emissions limits for this rule.

Comment 4: Commenter 17914 is concerned that available CEMS equipment is not accurate enough in
commercial field applications to reliably report total PM at the proposed MACT emissions limit for new
coal. The commenter states that for a supplier of new boilers and associated AQCS equipment, these
extremely low limits present a significant challenge for them to provide performance guarantees in light
of the inaccuracies of the reference methods for PM. The commenter notes that the proposed rule
indicates no allowance was made for data collected at or below the MDL and instead a default value of
the MDL was used, and suggests this logic would appear flawed, as setting a compliance limit that is
only 2 times the MDL for the test method which could result in errors as high as 50%. The commenter
references U.S. EPA "Review of National Primary Drinking Water Regulations: Analytical Methods -
Reassessment of Practical Quantitation Limits, noting that the EPA guidance suggests a multiplier of 5-
10 times the MDL for determining the PQL (in absence of sufficient inter-laboratory study data).

Response to Comment 4: In response to comments, the final rule does not have a total PM limit. The
facilities also have the option of periodic filterable PM testing in lieu of the installation of PM CPMS.
The EPA has also finalize alternative equivalent compliance options by establishing a total non-Hg
metals limit and individual non-Hg metal limits.

Comment 5: Commenter 17621 performed an analysis of method sensitivity to evaluate the ability of
test methods to measure HAP and surrogate parameters at the MACT limits, and includes a summary
table to the test method adequacy in their comments (Table 2-1). The commenter notes that as the
proposal also requires facilities to establish operating limits for some HAP based on initial performance
tests, which would then become the effective emissions limits for that facility. According to the
commenter, as those operating limits would be lower than the MACT limits, there may be additional
restrictions on the use of test methods beyond those indicated in the table.

Response to Comment 5: The final rule has removed the requirements for operating and fuel limits
with the exception of a PM CPMS and provides the option for periodic testing for non-Hg HAPs. Hg
sorbent monitoring allows for sensitivities below the emission standards.

Comment 6: Commenter 18034 states the proposed emission limits for some of the pollutants are very
near and in some cases significantly less than the documented MDL of the required emissions testing
and monitoring methods and even contradict certain recordkeeping provisions, which makes it
impossible for companies to demonstrate compliance with the emission limits. The commenter
recommends the EPA bring the emissions limits into harmony with the capabilities of the prescribed
methods and procedures for demonstrating compliance. The commenter provides specific examples for
proposed Hg limits for new coal-fired EGUs under the greater than or equal to 8,300 Btu/lb subcategory.

Response to Comment 6: The proposed Hg limit for new coal-fired EGUs was measured within the
calibration range of the analytical technique and met all QA/QC criteria of Method 3 0B in a 4-hour run.

Comment 7: Commenter 17715 notes that NIST traceable standards, gaseous oxidized standards
traceable to NIST and agreed to standard Hg vapor curves are not available, and without them there will
be non-uniform reporting of emissions.

62


-------
Response to Comment 7: It is the EPA's position that the Interim EPA Traceability Protocol for
Qualification and Certification of Elemental Mercury Gas Generators and the Interim EPA Traceability
Protocol for Qualification and Certification of Oxidized Mercury Gas Generators both published on July
01, 2009 are adequate to establish the NIST-traceability necessary for mercury monitoring programs at
this time. The major vendors of mercury CEMS have, for some time, been marketing elemental mercury
calibration gas generators that are directly traceable to NIST elemental mercury reference standards. We
agree with the commenters' point that NIST does not currently directly certify oxidized mercury gas
generators. However, oxidized gas generator NIST traceability is established through the assessment of
the individual components of the calibrator. The interim protocols for certifying mercury gas generators
allow sufficient flexibility to certify the gas generators in an appropriate range from existing NIST
traceable gas standards. The EPA does not believe it necessary to make available standard mercury
vapor pressure curves in order to implement the mercury monitoring program set forth in this rule as the
EPA's primary approach to NIST traceability for calibration gases is based on direct comparisons with
NIST reference materials and standards.

Comment 8: Commenter 17790 believes the EPA should specify specific guidelines for analytical
detection limits stack testing for non-Hg HAP metals and how to handle results that are below the
detection limit.

Comment 9: Commenter 17800 believes the non-Hg metals data collected during the 2010 ICR showed
reported detection limits for laboratory analysis that were highly variable even for data for the same
metal and from the same laboratory. The commenter suggests the EPA specify minimum detection
limits and procedures for combining front and back half fractions to report total concentrations in order
to determine compliance on a consistent basis.

Response to Comments 8-9: The MDL for non-Hg metals will depend on volumes samples and the
analytical finish used. Table 5 will be revised to specify the procedures for handling MDL results while
adding up multiple fractions.

Comment 10: Commenter 17902 believes the EPA must allow for a margin of compliance when setting
the final MACT standards as the measurements for Hg and other HAPS in the rule are completed at very
low levels of detection, leaving a greater potential for error.

Response to Comment 10: As more thoroughly discussed in Section 4A03, the emission limits for new
and existing sources were set at a minimum of three times the RDL to provide for measurement and
process variability at low levels when the UPL based on the data was not greater than three times the
RDL.

Comment 11: Commenter 17775 agrees that performance testing for units using CEMS should not be
required any more frequently than every 5 years. The commenter also supports inclusion of a reduced
testing provision for tests conducted more frequently. However, the commenter does not believe that the
EPA has provided sufficient support for many of the testing requirements in this proposal. Moreover, the
commenter does not believe that the 50 percent criterion is reasonable given the extremely low levels of
the EPA's proposed limits. The commenter requests that the EPA remove this restriction. The
commenter states the EPA has provided no reason for this restriction, or data suggesting that any source
could achieve 50% of the proposed emission limits, some of which are established at or near the
detection limit. The commenter does not understand how a source could test at a percent of the detection
limit. The requirement that source and control device operation remain consistent with prior successful
testing should be sufficient to ensure representativeness of the prior test(s).

63


-------
Response to Comment 11: In the final rule, there is no requirement for periodic stack testing where a
CEMS is used. The QA requirements for a CEMS, including Relative Accuracy Test Audits, are
adequate to ensure that the CEMS data remain valid for purposes of determining compliance with the
emission limits under this rule. The EPA disagrees and will retain the 50% criterion for reduced testing.
Sources operating at low levels can show compliance with the 50% limit by increased sampling
volumes. Also, the sources may opt to use CEMS or CPMS in lieu of the repeated periodic testing.

Comment 12: Commenter 17730 suggests the EPA specify minimum detection limits for laboratory
analysis for all pollutants and provide procedures for calculating total PM combined concentrations of
single metals and total non-Hg metals. The commenter notes that based on data collected in the ICR, the
reported detection limits for laboratory analysis were highly variable even for data for the same analyte
from the same laboratory. The commenter suggests that to determine compliance on a consistent basis,
the EPA needs to specify minimum detection limits and procedures for total PM for combining the front
and back half fractions to report total concentrations.

Response to Comment 12: The EPA disagrees that we should specify a prescriptive minimum detection
limit for laboratory analysis of all pollutants. Minimum detection limits will improve with future
technology and analytical techniques. Since total PM has been removed from the final rule, procedures
for combining total PM are not necessary.

Comment 13: Commenter 18443 suggests Hg, PM and HC1 CEMS should be used as compliance
indicators and not compliance methods. The commenter notes that the precision and accuracy of the
current continuous HAP emission monitoring is not field proven to reliable reflect actual emissions data.
The commenter believes very low HC1, Hg and PM concentrations are difficult enough to measure using
stack tests (as evidenced by the numerous values at or below detection levels in the ICR data set), and
accurately measuring these concentrations with CEMS is nearly impossible. According to the
commenter, to date Hg, PM and particularly HC1 CEMs have not been designed to measure very low
pollutant concentrations. The commenter believes that the EPA should recognize the limitations that
these CEMS have and use them only as an indicator of compliance, not as a compliance method.
According to the commenter, these shortcomings, when used in series to determine emission rates, will
result in substantial monitor downtime and the potential for numerous non-compliance events.

Response to Comment 13: An Hg CEMS or an HC1 CEMS are options for use as the performance test
method for the applicable Hg and HC1 emission limits. If a source is concerned about the use of these
methods in such a manner, the rule provides for other options (sorbent trap monitoring for Hg and stack
testing for Hg and HC1). There is no requirement to use a PM CEMS as a direct performance test
method for the PM emission limit. The PM CPMS is used as an operating parameter monitoring
approach to demonstrate compliance with a site-specific operating limit expressed in terms of the raw
output of the PM CPMS. The operating limit aids in ensuring that the source is operated and maintained
in accordance with good air pollution control practices to minimize emissions so that the source can
continue to operate in compliance with the emission limit as demonstrated in a periodic stack test. The
final rule does provide for the use of a PM CEMS to determine compliance with the filterable PM
emission limit if the source elects to use this approach (see the final preamble for further discussion).

Comment 14: Commenters 17316 and 17386 state that establishing HAP emission limits at the
boundary of what can be detected by available analytic techniques does not seem reasonable and that the
incremental benefits (HAP reductions) to be achieved by extending emission limits to such low levels,
lying at the edge of detestability, do not seem justified.

64


-------
Response to Comment 14: As further discussed in Section 4A, the emission limits are set at levels
which EPA believes are consistent with the requirements of the CAA.

Comment 15: Commenter 18023 believes the EPA should not use data that is below the MDL to
establish the MACT floor. The commenter states that despite not being able to "meaningfully quantify
the concentration(s)," the EPA used data that was identified as being "below detection limit" (BDL) or
"detection level limited" (DLL) when establishing the MACT floors. The commenter suggests this
means that many of the new and existing source MACT limits are based on data that is unquantifiable.
The commenter references the comments submitted by EPRI that discusses that using BDL and DLL
data also caused several of the new source limits to be so stringent that they are actually below the
applicable method sensitivity. The commenter recommends the EPA should only use values that are
above the MDL in calculating the MACT floor.

Response to Comment 15: The EPA's treatment of the data is consistent with the recommendation. All
data determined to be below the detection limit was treated as measured at the method detection limit for
use in the floor. Further discussion of the treatment of BDL and DLL data can be found in 4A03 of this
document.

Comment 16: Commenter 17821 states the EPA's effort to set emission limits for all HAP emitted by
EGUs is greatly complicated by the fact that a number of HAP were emitted at levels at or below the
reporting limits for the test methods required for collection of HAP emissions data during the ICR. The
commenter cites Amoco Oil Co. v. EPA, stating that the legal history is that an emission limit must not
be set below the quantification level of the method chosen for demonstrating compliance, and that if an
emission limit is set below the quantification level, then as the court in Amoco Oil cautioned, the limit
would be unenforceable. The commenter also cites a January 2011 memo in which the EPA
acknowledged that measurements at levels below analytical detection and quantitation levels are
associated with increased measurement uncertainty. The commenter provides additional discussion on
quantitation limits and recommends that the EPA use quantitation limits rather than detection limits
when establishing limits for the new standard.

Response to Comment 16: As further discussed in sections 4A03/4 of this document, we believe that
the procedures used in managing BDL data in establishing the floor values and setting emissions limit
and we have discussed this procedure in detail elsewhere in this document. The EPA is not setting
standards below the detection limit so those comments are moot.

Comment 17: Commenter 17873 believes that the new source Hg limit is below the detection limit of
any current or planned instrument, and even if a new unit could meet the limit, there is no way to assess
compliance. The commenter suggests the EPA's proposed new source limit for Hg would act to ban the
construction of new coal plants. According to the commenter, nothing in the CAA authorizes or
mandates this result, and it has significant implications for the long-term energy security of the nation.
The commenter believes the EPA should not be setting national energy policy through a CAA
rulemaking.

Response to Comment 17: The Hg limit for new coal-fired EGUs was measured within the calibration
range of the analytical technique and met all QA/QC criteria of Method 3 OB in a 4-hour run, meaning
that current instruments can measure mercury emissions at the level of the emissions standards. The
agency disagrees with the commenter's assertion that the mercury emissions limit for new sources
would act to ban construction of new coal plants; on the contrary, at least one or more existing EGUs

65


-------
reported mercury emissions at or below the emissions limit for new sources, for values from existing
units were used to establish the mercury limits in the rule.

2. Concerns with specific test methods.

Comment 18: Commenter 17711 notes several potential issues with the EPA Methods 5, 23, 26/26A
and 29 as reference methods for measuring source emissions of PM, dioxins/furans, HC1, and Hg. The
commenter notes that the extraction, processing, and analysis of samples can lead to random errors to
the final measurement and provides examples such as where compound concentrations are inconsistent
due to changes in fuel mix over time, contamination occurs, or improper instrument calibration or matrix
interference.

Response to Comment 18: The agency disagrees with the commenter's view that potential issues with
the listed EPA Methods renders them less than useful for this rule. The rule identifies potential
problematic areas for the Methods, and provides alternatives, both within the Methods and through the
use of other means to determine compliance. Should an EGU owner or operator believe the potential
issues with emissions testing to be problematic, he or she can choose to use continuous emissions
monitoring systems to demonstrate compliance. The EPA Method 23 is not required for the final rule.
The EPA agrees that "extraction, processing and analysis" can lead to random error and variability that
would not be seen due to the truncation of the data set at the MDL. This is the basis for the emission
standards being set at no less than 3 times the RDL as discussed in the preamble and 4A03 of this
document.

Comment 19: Commenter 17711 states that aside from a 1996 study by R. Shigehara, the commenter is
not aware that the EPA has published any results from studies necessary to determine the detection and
quantitation limits of its reference stack test methods nor that the EPA has even proposed a method for
determining the values of these parameters of the reference methods. The commenter states that of the
five test methods that were utilized to collect data for setting the proposed MACT standards and would
be used to demonstrate compliance with the proposed standards, the EPA has provided the detection
limits for only Method 29, and even in those cases no EPA reports are available to assess the validities
of the detection limits specified with the test methods. According to the commenter, even in the absence
of such reports, if one assumes that these values are correct and then applies the 3.18 Student-t
multiplier for three samples to the detection limits, the estimated quantitation limit of Method 29 would
be 1.8 [j,g/m3. An examination of the data in the EPA's MACT database shows that it includes
measurements below these values. The commenter suggests that values below a method's quantitation
limit should not be used to set emission standards.

Response to Comment 19: The EPA disagrees with the comment. The Method 29 detection limits
published in the method only represent approximate estimates for each analytical technique to provide a
guideline on choosing the appropriate analytical technique. The EPA Method 5 MDL was published
with the promulgation of Method 51. The Method 26 and 26A typical method detection limits were also
published. As more thoroughly discussed in 4A03 of this document, the EPA disagrees that only values
above the method's quantitation limit should be used.

Comment 20: Commenter 17725 provides a discussion regarding a caveat of Method 30B that allows
for an alternative approach for quantifying low masses. The commenter notes the caveat allows for
estimates for masses below the lowest point on the calibration curve (i.e., LOQ), but above the MDL.
The commenter suggests this caveat is of significance because there are no ongoing quality
assurance/quality control (QA/QC) requirements for the response factor mass estimates. According to

66


-------
the commenter, this fundamentally differs from masses that fall within the calibration curve; all points
used in the generation of the calibration curve must be within ±10% of the expected value. Furthermore,
according to the commenter, continuous calibration verification standards (CCVS) must be performed
no more than every 10 field sample analysis and also be within ±10% of the expected value for the field
samples to be considered valid. The commenter asserts that therefore, any masses and ultimately effluent
concentrations that are determined using the response factor approach are not of the same quality or
uncertainty a those determined by the calibration curve (i.e., masses above the LOQ). According to the
commenter, all masses determined above the LOQ are of acceptable quality and a known uncertainty of
±10 percent, and conversely, masses determined using the response factor approach are of unknown
quality and uncertainty, they are merely estimates.

Response to Comment 20: The agency agrees with the commenter that this could be a concern,
especially in light of the low Hg concentration levels that may be measured under this rule. Therefore,
we are proposing in a separate rulemaking an amendment to Method 30B that would lower the specified
Hg concentration for which the tester must have his sample results within the calibration curve from 0.5
|ig/dscm (current specification) to 0.01 |ig/dscm. This will mean that in the future, concentrations down
at least to 0.01 |ig/dscm will be of known quality as described by the commenter.

Comment 21: Commenters 17725 and 18498 disagree with the EPA simply stating a generic
MDL/LOQ for the entire Method 30B, as MDL and LOQ data collected vary among labs, analyzers and
analysts. One commenter suggests that although the theoretically calculated MDL and LOQ has been
shown to be as low as 2ng, in practice the QA/QC at that level is not obtainable. The commenters
believe that in practice lOng is a reasonable range for the LOQ to collect data of acceptable quality and
known uncertainty (i.e., ±10 percent) and 5ng is pushing the envelope on the lowest LOQ that should be
used when evaluating low level effluent concentration data (i.e., < 0.1[j,g/m3). The commenters suggest
the response factor approach is used for merely estimating masses below the LOQ, but above the MDL
and should not be used when establishing an emission limit as the data of are of unknown quality and
uncertainty. According to the commenters, it then follows for a typical ICR test (i.e., 2hr test run
collecting 1201 of volume) that effluent concentrations ranging between 0,04|ig/m3 and 0.08[j,g/m3 are
the lowest that can be reasonably be determined with acceptable quality and uncertainty.

Response to Comment 21: The EPA agrees that, in general, the response factor approach in Method
30B should not be used for estimating masses below the LOQ, but above the MDL when reporting
emissions data for compliance determination as these data of are of unknown quality and uncertainty. It
is the EPA's intent to ensure that reported Hg emissions data are of known and acceptable quality. In
response, the EPA is about to propose an amendment to Method 30B that would lower the specified Hg
concentration for which the tester must have his sample results with the calibration curve from 0.5
|ig/dscm (the current specification) down to 0.01 |ig/dscm. This will mean that in the future
concentrations down to at least 0.01 |ig/dscm will be of known quality. The EPA disagrees that effluent
concentrations ranging between 0.04 (j,g/m3 and 0.08 (j,g/m3 are the lowest that can be reasonably be
determined with acceptable quality and uncertainty. In fact, recent testing conducted as part of the
Utility MACT ICR demonstrated that an average stack Hg concentration of 0.01 (j,g/m3 could be
measured as part of a triplicate 4 hour emissions test with all Method 30B performance criteria being
met.

Comment 22: Commenter 17725 believes the EPA Methods 26A and 26 have proven to be reliable
stack testing methods and produce high quality results; however, there are limitations with each method
with regards to detection limits. The commenter questions if either method can consistently provide
reliable data for compliance determination for the proposed limit as factors such as blank contamination,

67


-------
positive and negative biases due to flue gas interferences, and analytical errors raise questions. The
commenter believes the proposed HC1 emission limit of 0.00030 lb/MMBtu is very low with respect to
the in-stack detection limit for HC1. The commenter notes that based on multiple sites that underwent
testing during the ICR, in-stack detection limits were in the area of 0.000050 lb/MMBtu, and the ICR
required very long run times of 180 minutes for increased detection. According to the commenter, even
with the long run times, the proposed emission limit was only six times greater than the in-stack
detection limit for the HC1. The commenter asserts that in theory, HC1 can be measured at this level but
the issue is the ability to produce reliable, repeatable, high quality results this close to the detection limit.

Response to Comment 22: We agree that there are method detection level capability differences
between Methods 26 and 26A and both are allowed by the rule. The source has the option to choose the
method and the required sampling periods consistent with expected emissions levels and the procedures
for managing method detection levels in determining compliance.

Comment 23: Commenter 17621 suggests that Method 29 does not have adequate sensitivity to
measure antimony accurately at the alternative individual metal MACT limits for existing units. The
commenter provides a table (Table B-l) which shows that at the individual metals MACT limits for new
coal EGUs, most metals would not be measured accurately. The commenter notes that ASTM D6764-02
states a lower limit of quantitation for Hg of 0.5 (J,g/m3, which corresponds to a stack emission for coal-
fired units of approximately 0.45 lb/Tbtu and this level of sensitivity is adequate to measure Hg at the
MACT limit for existing coal units, but not at the limit for new units. The commenter also discusses that
analytical detection limits do not consider the many sampling- and matrix-related factors that can raise
detection limits at the stack. However, the commenter believes method sensitivity could also be better in
practice than indicated in Table B-l due to improvements in instrumentation and collection of larger
sample volumes than required by the ICR. According to the commenter, therefore, this comparison was
not given as much weight as the ICR results in the determination of method adequacy.

Response to Comment 23: The individual metal MACT limits have been reassessed to ensure that they
are no less than three times the RDL including the data collected with Method 29. ASTM 6674-02 has
been removed from Table 5 for use with compliance determination to ensure adequate sensitivity for
compliance due to the sample volume restrictions of the method. The EPA agrees that method sensitivity
will be improved in the future with improvements in instrumentation and the allowance to run higher
sample volume than required minimums listed in Tables 1 and 2.

68


-------
5A05 - Testing/Monitoring: Operating parameter monitoring

Commenters: 17197, 17316, 17383, 17402, 17622, 17627, 17638, 17675, 17677, 17681, 17689, 17696,
17705, 17715, 17716, 17718, 17725, 17730, 17736, 17740, 17752, 17754, 17757, 17758, 17761, 17767,
17772, 17775, 17776, 17790, 17795, 17798, 17800, 17804, 17805, 17807, 17808, 17813, 17816, 17820,
17821, 17856, 17868, 17870, 17873, 17876, 17881, 17886, 17902, 17912, 17914, 17923, 17925, 17928,

18014,	18015, 18021, 18025, 18037, 18426, 18428, 18429, 18437, 18498, 18539, 19033, 19114, 19120,
19121, 19536, 19537, 19538, 18023

1. Objections to parametric operating limits for units with CEMS (section 63.10007(c)).

Comment 1: Numerous commenters (17383, 17402, 17622, 17627, 17638, 17675, 17677, 17681,
17689, 17696, 17705, 17715, 17716, 17718, 17728, 17730, 17736, 17740, 17758, 17761, 17767, 17772,
17775, 17798, 17807, 17808, 17813, 17856, 17868, 17873, 17876, 17886, 17902, 17914, 17923, 17925,

18015,	18025, 18037, 18428, 18429, 18437, 18539, 19114 19120, 19121, 18023) oppose the proposed
control-device-specific operating limits for demonstrating ongoing compliance on units that are
equipped with CEMS because these commenters believe such parametric limits are duplicative to the
MACT floor emissions limits that EGUs must meet, unduly burdensome, decrease operational
flexibility, make it difficult to operate control equipment at optimum efficiency, and/or inconsistent with
longstanding EPA policies under 40 CFR part 64.

Comment 2: Several commenters (17775, 17868, 18539, 19120) state that proposed section
63.10007(c) is unclear because it does not indicate whether every affected facility is subject to the
requirements to establish parametric operating limits, and recommends that the final rule should make it
clear that units with CEMS are not required to perform parametric monitoring or take operating limits.
Commenters believe that the purpose of operating limits is to determine compliance between
performance tests and that units with CEMS or sorbent traps would not require such limits. Commenters
17758 and 17868 state that the EPA has not provided justification for requiring units with CEMS to also
perform parametric monitoring for the same HAP or surrogate.

Comment 3: Commenter 17868 states that section 63.10022(b) provides that if you demonstrate
compliance through performance testing you must establish operating limits in Table 4. According to the
commenter, since all EGUs must demonstrate initial compliance with each emission limit "through
performance testing," and the proposed rule defines "performance testing" to include the first 30
operating days of CEMS data, the proposal appears to require that EGUs meet operating limits for all
relevant control devices and load regardless of the "performance testing" option they choose (see, e.g.,
proposed section 63.10005(a) and Table 5 (including stack tests, CEMS, and LEES in the list of
"performance testing" options)). The commenter observes that the other provisions cited in section
63.10011(b) provide little clarification, that proposed section 63.10007 does not discuss applicability,
and that with the exception of the filterable PM limit applicable to units using PM CEMS, Table 7 does
not distinguish between compliance options; instead, Table 7 refers to various parameters depending on
which control device "your operating limits are based on." The commenter also states that section
63.10011(c)(6) addresses fuel sampling, not operating limits and that section 63.10011(b)(6), the
provision the EPA likely meant to cite, refers only to control devices and not compliance options.
Commenter 17868 concludes that the preamble discussion contains numerous inconsistent statements
and no rationale by which one could determine the EPA's intent with respect to these operating limits
for units using CEMS and sorbent trap monitoring systems.

69


-------
Comment 4: Commenter 17718 states that the EPA should require no proof of compliance beyond a
properly calibrated and installed CEMS and that the EPA should revise both the language and tables in
the rule to clarify its intent as it relates to CEMS used for demonstrating compliance. According to the
commenter, HC1 CEMS are not commercially available or adequate for in-stack measurements from
electric utility units and likely will not be available by the compliance date of the rule. The commenter
asserts that sources will be forced to either take a fuel limit or an operating parameter limit and that the
fuel analysis limit is impractical as it relates to a coal-fired facility because of chlorine variability that is
inherent in coal, that it will be impossible to control fuel deliveries in such a manner as to eliminate the
possibility of burning coal with chlorine content above that which was used during compliance testing.

Comment 5: Commenter 18428 states that the preamble discussion contains numerous inconsistent
statements and no rationale by which one could determine the EPA's intent with respect to these
operating limits for units using CEMS and sorbent trap monitoring systems. For example, according to
the commenter, the EPA suggests in the following statements that operating limits apply only to units
without CEMS:

•	IGCC units or units combusting coal or solid oil-derived fuel with PM controls but not using PM
CEMS to demonstrate continuous compliance would also be required to conduct parameter
monitoring and meeting operating limits established during performance testing.

•	The second option that we are proposing would be for units without SO2 or HC1 CEMS but with
S02 emissions control devices. For these units, parameter operating limits established during
performance testing, would be monitored continuously, along with the already-mentioned
frequent (every 2 months) HC1 emissions testing.

•	When a performance test is conducted, we are proposing that parameter operating limitations be
determined during the test. Performance tests to demonstrate compliance with any applicable
emission limitations are either stack tests or fuel analysis or a combination of both, "... units
equipped with devices that control PM and HC1 emissions but do not elect to use CEMS, would
determine suitable parameter operating limits ..."

The commenter notes that in another statement, the EPA suggests that all EGUs with PM controls must
establish operating parameters, whether or not they have CEMS:

•	" those EGUs with PM emissions controls, without HC1 CEMS but with HCI control devices, or
for LEE, we are proposing that you monitor during initial performance testing specified
operating parameters that you would use to demonstrate ongoing compliance."

Comment 6: Commenter 17775 asserts that the EPA must recognize that there are limitations on the
conditions under which the EPA can require EGUs to establish operating parameters because to comply
with CAA section 112, the EPA assessed capabilities of controls under conditions specified in the 2010
ICR and established compliance testing and compliance assurance requirements consistent with that
assessment, and the EPA has proposed continuous monitoring, initial stack testing, or periodic fuel
analysis that it presumably believes are consistent with that assessment.

Comment 7: Several commenters (17775, 17902, 17925, 18539) state that as long as an EGU is
complying with one of the options for demonstrating "continuous compliance," there is no basis to allow
the Administrator to specify some other test be conducted under some other set of conditions.

70


-------
Comment 8: Commenters 17740 and 17808 are concerned about adding unnecessary costs for sources
demonstrating continuous compliance via CEMS and is also concerned that the proposed requirements
will duplicate existing requirements in title V CAM conditions.

Comment 9: Commenters 17873 and 17886 express concern that the secondary operating requirements
also create a "double jeopardy" compliance risk: as long as the EGU MACT includes these limits, a unit
could be in compliance with the underlying emission standard (and therefore protecting the
environment) but find itself out of compliance with a related operating limit.

Comment 10: Several commenters (17775, 17808, 17813) believe that it is inappropriate to hold EGUs
to limitations on the operations of its controls set during brief performance testing periods that may not
reflect the full range of operating conditions that can comply with the emissions limits. The commenters
express the need to be able to make adjustments based on coal variability and other operating conditions
that can differ from the conditions occurring during performance tests. Furthermore, the commenters
express concerns that many coal units are utilized to generate variable intermediate loads to meet
variable electrical power demands and thus, do not operate in the steady state associated with normal
performance tests. Commenter 17716 contends that such normal load variations are inconsistent with the
proposed requirement to establish a minimum pressure drop and liquid injection rate on a wet PM
scrubber because normal pressure drops at low load will result in the reporting of deviations compared
to pressure drop limitations set at high load. These commenters advise that when variable load
operations are combined with variable coal properties, operating parameters can differ significantly from
steady state performance test conditions. These commenters contend that based on their operating
experience, as long as the unit is in compliance as measured with the CEMS, there is no need to track or
limit operating parameters because they vary by design. Commenter 17705 notes that the EPA has
recognized many times that CEMS represent the best available method for tracking compliance with
emissions limitations at a regulated source, and the commenter refers to provision of 40 CFR part 64
(the CAM rule) that state when a CEMS is specified by the applicable standard, the requirements of part
64 do not apply to that emission standard. The commenter cites the following reference to CEMS from
the preamble to the CAM rule: "The EPA believes that these types of monitoring are preferable from a
technical and policy perspective as a means of assuring compliance with applicable requirements
because they can provide data directly in terms of the applicable emission limitation or standard."

Comment 11: Commenter 19121 states that they support the use of parametric and fuel data to show
compliance when outlet monitoring is not available. However, the commenter states that for those HAP
where a numerical limit and a monitoring method is set, other secondary operating restrictions should
not apply. According to the commenter, such an approach would severely curtail operating flexibility
and limit demand response.

Comment 12: Commenter 17767 states that it is unreasonable to assume that ongoing compliance
would meet the operating parameter average if compliance could not be met during the compliance stack
test. According to the commenter, the proposed rule makes no mention of the tolerance of operating
parameter limits set during initial compliance testing for any pollutant or surrogate. The commenter
asserts that if an average of the tests runs is used to set a limit, then even the initial passing compliance
test would have periods of noncompliance during the runs with parameters outside the final averaged
target parameters.

Comment 13: Commenter 18021 states that one set of operating conditions do not produce operating
limits that are properly reflective of systems' capabilities. The commenter notes that current operation
must be flexible enough to meet not only load swings but also future regulations.

71


-------
Response to Comments 1 - 13: The rule does not require monitoring operating limits where a CEMS is
used for the applicable standard. If a source has PM control equipment and uses a PM CPMS based
operational limit, no control device monitoring is required. The same is true for HC1 or SO2 controls for
coal-fired and other solid fuel affected units. The only additional operating parameter requirement will
be for liquid oil-fired EGUs whose owners or operators choose to use quarterly acid gas emissions
testing. The appropriate parameters, monitoring method, QA/QC provisions, and data reduction
requirements will be established in a site-specific monitoring plan; please see the final preamble for
further discussion. With respect to the need for variability in establishing parameter limits because of
load changes or changes in fuel, the rule provides for establishing different operating limits based on
different loads. Also, see the response to the following comments about establishing "deviations" from
operating limits.

2.	Duplication of pollutant testing.

Comment 14: Commenter 17716 states that the EPA has established alternative compliance limits for
various HAP groups, providing sources with flexibility to measure the PM limit, limits for individual
metals, or a total non-Hg metals limit to establish compliance for metal HAP and to monitor S02 or HC1
for acid gas HAP. The commenter states that the proposed rule requires stack tests not only for the
pollutant but also for the surrogate. According to the commenter, performance tests should be matched
to either the pollutants or the surrogates chosen by the source to show compliance, the extra tests are
redundant.

Response to Comment 14: The EPA agrees that if the source elects to comply with an surrogate
standard such as filterable PM instead of the alternative equivalent total or individual non-Hg HAP
metals, then the only performance test to be performed is the test to show compliance with the emission
standard that applies (in this example, the filterable PM limit). The final rule clarifies this position.

3.	General objections to enforceable parametric operating limits (section 63.10007(c)).

Comment 15: Multiple commenters (17402, 17622, 17675, 17677, 17681, 17696, 17705, 17715, 17716,
17728, 17730, 17775, 17800, 17808, 17873, 17912, 18023) find that the proposed requirements for
operating parameters at section 63.9991(a)(2) particularly problematic because the proposed definition
of "deviation" includes operating limits, but the commenters feel operating limits should not be a
reportable deviation since they are indicators of compliance and not emission limitations.

Comment 16: Multiple commenters (17730, 17775, 17800, 17820, 17868, 17912, 17914, 18428)
believe that the proposed usage of parametric operating limits deprives sources of the use of any control
device margin, and allows enforcement for events beyond the operator's control. Commenters state that
the EPA's current proposal is based on the faulty assumptions that the values of the parameters
identified by the EPA have a direct relationship to the level of emissions, and that exceedances of those
limits therefore indicate an exceedance of the emission limit. The commenters' view of operating
parameters is that to the extent possible, operators will contract for control equipment designs that
provide a "margin of compliance" with applicable emissions limits. According to the commenters, in
addition to reducing the possibility of an exceedance of the limit, this margin is intended to provide
flexibility for the source to account for inevitable control equipment or operational problems. The
commenters believe that under the proposed parametric monitoring regime, sources with a margin of
compliance will lose part of that margin of compliance if they conduct performance testing under
normal operations because they will establish operating limits that would require them to continue to
over-control forevermore. The commenters suggest that the only way such sources could avoid

72


-------
surrendering whatever margin of compliance they have would be to deliberately reduce performance of
their controls to attempt to generate the least stringent operating limits consistent with achievement of
the applicable emission standard. The commenters conclude that the proposal encourages sources to
focus their attention on learning how to manipulate operations to allow testing as close as possible to
their emission limit by reducing performance of their controls. These commenters generally believe that
the parameter ranges in Table 4 must be established as corrective action levels, not enforceable
operating limits and each of these commenters recommends that the final rule adopt provisions similar
to those for CAM under 40 CFR part 64 for assuring continuous compliance with the MACT standards
rather than the proposed provisions for parametric monitoring. Commenter 17775 refers the EPA to an
attached report by McRanie Consulting entitled "Comments on the Proposed Utility MACT Rule -
Operating Parameters" (July 2011). Commenter 17675 states that other MACT standards like subparts
LL and MM take the right approach to parametric monitoring. The commenter states that these standards
require that corrective actions are taken to respond to parameter excursions and that the failure to take
corrective action is a violation.

Comment 17: Several commenters (17675, 18037, 18429) generally believe that the CAM approach
(that allows operators to propose excursion levels and response requirements for approval by the title V
permitting authority) is a proven method of obtaining reasonable assurance of compliance while
recognizing the wide variations in parametric ranges that can occur during operating periods that are in
compliance with the underlying emissions limit.

Comment 18: Commenter 17912 states the operating parameters may push events beyond the operator's
control into an unavoidable enforcement posture. According to the commenter, for example, for
compliance with the proposed total particulate emission limit for new and reconstructed EGUs, the
proposed emission limit is 0.050 lb/MWh as measured by a manual stack test. However, the commenter
asserts, if a CEMS for filterable particulates is used to demonstrate compliance, then, to be in
compliance on a continuous basis, the owner or operator must "[mjaintain the PM concentration
(mg/dscm) at or below the highest 1-hour average measured during the most recent performance test
demonstrating compliance with the total PM emissions limitation." The commenter states that to
demonstrate continuous compliance, the EPA proposes to average the emissions measured by the CEMS
over 30 days for reporting purposes. Nowhere, however, according to the commenter, does the agency
explain how an emission limit derived from a single, one-hour measurement can reasonably be expected
to account for the all of the variable conditions that may occur during any given day, let alone a month
or a year. The commenter states that federal courts have explained that an emission standard is
'"achieved in practice' [when it] is interpreted to mean 'achieved under the worst foreseeable
circumstances'" and cites Sierra Club v. EPA, 167 F.3d 658, 665 (D.C. Cir. 1999).

Comment 19: Commenter 17873 states that in setting operating limits the EPA unreasonably extends its
authority beyond establishing the appropriate emission standard to governing the way a company
operates a unit to meet a standard. According to the commenter, the prescribed operating parameters
(scrubber pH, etc.) and averaging method used to demonstrate compliance with those limits create a
secondary and overlapping regulatory obligation likely to result in excessive control process cost and
material waste.

Comment 20: Commenters 17873 and 17740 state that operating limits make it difficult to bring
additional renewable resources on-line. Commenter 17873 states that designing operating strategies to
include multiple process set points for control equipment at different loads is difficult. The commenter
notes that the ability of its coal generating units to change load quickly and efficiently is critical in
accommodating variable wind energy. The commenter is concerned about the adverse effect on grid

73


-------
integration due to such additional plant operating constraints at the same time the company is supporting
significant renewable energy penetration on its system.

Comment 21: Commenter 17902 states that the deviation of operating limits does not necessarily
indicate that an emission limit has been exceeded, and in certain instances, could even suggest lower
emissions (such as increased pressure drop for a baghouse control). According to the commenter, due to
the stringency of the proposed MACT emission limits for EGUs, companies will not have an option to
allow air pollution control equipment to operate below optimal levels or in a manner that would
jeopardize compliance. The commenter recommends that the operating limits should only be applied in
this rule as a work practice standard with deviations requiring investigation and corrective action as
appropriate or necessary, but should not be considered non-compliance. The commenter further notes
that this approach should be applied along with revising the compliance demonstration measurement to a
12-month rolling average basis for the applicable MACT emissions limits in Table 1 or Table 2.

Comment 22: Commenter 17982 recommends that, instead effectively setting enforceable site-specific
operating limits that would have to be met at all times in addition to the emission limit for the surrogate,
the EPA should allow reasonable, flexible alternative compliance demonstration options, including less
frequent periodic stack tests - no more often than annually - and longer averaging times. According to
the commenter, it may be difficult to meet these site-specific limits at all times under all operating
conditions.

Comment 23: Several commenters (18023, 1775, 17800, 17821, 17868) state that a CAM approach has
already been upheld as sufficient to satisfy the CAA's requirements for demonstrating continuous
compliance in NRDC v. EPA, 194 F.3d 130, 135-37 (D.C. Cir. 1999).

Comment 24: Commenter 17705 states that no bases for the proposed parameters in Table 4 are
presented in the technical support documents. Commenter 17705 adds that the EPA should not consider
enforceable limits on control device operations unless the agency clearly demonstrates this is the only
means of assuring compliant emissions. Commenter 17705 states that establishing the appropriate
parametric limits must be done on a case-by-case basis as allowed under CAM rules.

Comment 25: Several commenters (17725, 17808, 18025) state that the proposed rule is not clear
regarding what the required response action would be in the event that a unit violated its parameter
operating limits, and the commenter suggests that a facility must initiate a corrective action to address
the excursion similar to what is required in 40 CFR part 64 for CAM.

Comment 26: Commenter 17716 recommends an alternative approach to establishing representative
control device operating ranges based on a statistical analysis of historical operating data during periods
when the control device was operating properly.

Comment 27: Commenter 18023 takes exception to the stated assumption in the preamble that a
baghouse or ESP can meet the proposed PM limits and the associated site-specific operating limits
continuously because under the rule, sources will not know the design criteria for the operating limit
until after an initial compliance test that will not take into consideration plant variability. Therefore,
according to the commenter, it is unclear what control technologies will be necessary to meet the site-
specific limit continuously. Commenter 18023 states that the site-specific limit is completely
unworkable and must be removed and that even if the EPA refuses to remove the site-specific limit, the
EPA must account for the added costs and burdens sources will inevitably encounter trying to meet site-
specific limits.

74


-------
Comment 28: Commenters 17870 and 18025 state that units with appropriate CAM plans and units
operating CEMS should not be required to have additional monitoring requirements.

Comment 29: Commenter 17776 states that the inclusion of operating parameter limits in the proposed
rule effectively lowers the numerical MACT floor. According to the commenter, it makes little sense to
set a MACT floor then establish a mechanism to tighten the limit. Likewise, asserts the commenter, with
a mandated monitor in place giving continuous, real-time readings in the units of the standard, the
collection of control parameters for the purpose of compliance determinations is burdensome, but more
importantly, completely unnecessary. The commenter states that in contrast, if the agency has
confidence in the operating limits as a mechanism of compliance, then the mandated PM monitors are
not necessary. According to the commenter, it should be noted that Hg and SO2 CEMS data was deemed
sufficient by the rule to assure compliance without the use of operating parameter limits.

Response to Comments 15 - 29: The EPA believes that continuous monitoring in the form of CEMS,
sorbent traps, or CPMS is needed or that frequent emissions testing is needed to ensure ongoing
compliance with this rule. In order to minimize costs and reduce burden, the rule has removed most
operating parameters except for: (1) the owner-defined signal from the PM CPMS, which remains as an
operating limit for those owners who choose to use PM CPMS; and (2) for acid gas emission limits, an
owner-defined parameter monitoring approach for liquid oil-fired EGUs that do not use the fuel
moisture certification approach, and do not use an HC1 or HF CEMS, but instead rely on quarterly
emissions testing. See the final preamble for further discussion. We have not required any other control
device parameter monitoring in the final rule. While we recognize the importance of continued control
device performance to ensure emissions minimization, we are aware that other rules that apply to these
units - including but not limited to the operating permits rule, the compliance assurance monitoring rule,
and the new source performance standards - already require ongoing parameter monitoring. Those rules
will remain in effect, so additional imposition of operating limits on those units would be redundant. The
limited operating limit requirements in the final rule address options (such as the PM CPMS in lieu of
quarterly testing) or the potential gaps for liquid oil-fired units.

4. Requests to make parametric monitoring requirements more like Compliance Assurance
Monitoring (CAM) Program.

Comment 30: Numerous commenters (17402, 17622, 17638, 17715, 17716, 17718, 17725, 17736,
17757, 17775, 17804, 17808, 17816, 17820, 17821, 17856, 18014, 18025, 18037, 18428, 18429, 18498,
18023) generally suggest that the final rule should incorporate more flexibility in setting parametric
monitoring ranges similar to the existing CAM program. These commenters suggest the following
specific revisions to proposed parametric monitoring provisions:

1. Several commenters (17716, 17725, 18498) state that some of the proposed parameters are either
unnecessary, inappropriate, or could otherwise be substituted with parameters that are already
monitored; for instance, wet scrubber parameters could be simplified based on scrubber pH and a
calculated liquid-to-gas ratio, where gas flow is measured using an existing stack flow monitor and
liquid injection rate is estimated based on the number of recycle pumps in service. According to the
commenters, for ESP-equipped units, the use of total power may not be representative of PM emissions
since removal efficiency is dependent on where the power is applied in the control device. The
commenters suggest that other alternatives might include the use of an ESP model for predicting
performance or specifying a minimum power level within each gas path. The commenters state that
these examples demonstrate other monitoring alternatives that provide a reasonable assurance of
compliance while allowing operators to implement more cost effective monitoring programs.

75


-------
2.	Multiple commenters (17402, 17715, 17689, 17808, 18037, 18539, 19114) believe that the EPA
should revisit the way operating parameters are set during performance tests that are typically completed
during high-load, steady-state conditions because the operating parameters captured during these tests
may not represent the variability of day-to-day operations across the full range of operating loads.
Commenter 17808 recommends that units with appropriate CAM plans should not be required to have
additional monitoring requirements. Commenters (17715, 17718, 17736, 17757, 17816, 17856, 18037,
18539, 19114) express concerns with operating limits changing every 2 months based on the most recent
performance test and the challenges of continuously revising operating procedures and alarm points. The
commenters are concerned that sources will have no confidence that they will be able to demonstrate
compliance over the full range of operating conditions that are normal for the source, and permitting
authorities will have an impossible task to track different sets of operating limits for each unit in their
jurisdiction.

3.	Multiple commenters (17402, 17718, 17627, 17736, 17757, 17816, 18037, 18539, 19114) believe that
as currently proposed, units would be constrained by unachievable operational parameters because the
set of operating limits that a unit measures during its first performance test would be its maximum
operating limits. According to the commenters, subsequent performance tests would further ratchet
down operating parameters until they are no longer achievable during a 30-day or annual averaging
period. The commenters state that control equipment operating characteristics during full load testing
will not be suitable to monitor low load performance.

Commenters 17775 and 17868 state that even the "detuning" of a control device during performance
tests will not ensure associated operating limits are necessary for compliance with the underlying
emissions limit. Several commenters (17775, 17800, 17820, 17821, 17868, 18428) add that the EPA has
previously recognized in the context of the NSPS and the CAM rule, "many sources operate well within
permitted limits over a range of process and pollution control device operating parameters," and
requiring sources to continuously maintain parameters that "happened to exist" during the most recent
performance test may not be "possible or wise." 62 FR 54,900, 54,907, 54,926-27.

Multiple commenters (17718, 17775, 17800, 17820, 17821, 17816, 17868, 18428) state that the
proposed control device parameters do not necessarily have a direct relationship to emissions but instead
are interrelated with various parameters so that a single parameter may vary widely with little effect on
emissions. The commenters acknowledge that the proposed provision of a 10% difference from the
average tested value recognizes some of the normal operational variability of control devices, but
believes the 10% margin will not be sufficient in some cases. The commenters conclude that without a
clear correlation between the proposed operating parameters and emission limits, imposition of those
values as enforceable limits unreasonably restricts operations and subjects operators to potential
enforcement without any reliable evidence of emissions exceedances.

4.	Commenter 17402 recommends that the operating limit should be based on the least stringent of the
three minimum performance test runs and not the average of the runs (assuming, of course, that all three
test runs demonstrated compliance with the MACT emission limits) because this would help account for
real-world variability in operating parameters and would assure compliance because this testing certifies
that when those (least stringent) operating parameters are met, the facility still meets the MACT limits.
Moreover, the commenter believes, as long as the facility is in compliance via a certified CEMS or stack
testing, there is no need to track the instantaneous values of operating parameters.

5.	Commenter 17402 states that the normal variability of operating conditions further suggests that
greater flexibility is needed for operators to substitute the EPA's proposed parameters, some of which

76


-------
are unnecessary or inappropriate, with parameters that are either already monitored by the facility or
parameters that would allow the EGU to implement more efficient monitoring. The commenter suggests
that the required parameters proposed for wet scrubbers could be simplified to simply scrubber pH and a
calculated liquid-to-gas ratio, where gas flow is measured using an existing stack flow monitor and
liquid injection rate is estimated based on the number of recycle pumps in service. The commenter
advises that FGD pressure drop varies with load and the number of recycle spray pumps that are in
service, and therefore, the absorber pressure drop is not a good indicator of FGD performance. The
commenter also advises that the proposed parametric requirements for ESPs (to establish minimum
hourly average secondary voltage and secondary amperage and calculate the total secondary power input
measured during the three-run performance test) fail to take into account which fields are being powered
and where in the precipitator they are located. The commenter further advises that the appropriate
secondary power will also vary with fuel and load making a minimum level set at a full load test
inadequate to assure compliance at all loads.

6.	Multiple commenters (17402, 17627, 17757, 17821, 18023, 18037, 18539, 19114) refer to existing
requirements under 40 CFR part 64 commonly known as CAM plans in title V permits and state that the
final rule should use the CAM program as the basis for parametric monitoring plans. The commenters
suggest that source operators should be able to rely on this existing framework, and to work with
permitting authorities to develop a set of parameters that make sense for the facility and its control
configuration. Commenters (17402, 17627, 17757, 18539, 19114) state that CAM plans were
specifically developed to assure PM limit compliance through the measurement of opacity even though
opacity is not a direct measurement of PM, but permitting authorities recognize opacity as an indicator
of control device performance, and there are approved plans that have formally documented the
appropriate use of this indicator in an ongoing monitoring program.

7.	Several commenters (17402, 17725, 18014, 18498) state that normal variability of operational
parameters should be taken into consideration in the EPA's proposed procedures for establishing the
compliance ranges. According to the commenters, the EPA proposes that EGUs would be required to set
parameters based on 4-hour block averages during compliance tests and would demonstrate continuous
compliance by monitoring 12-hour block average values below or above the lowest or highest 1-hour
average measured during the most recent compliance test. The commenters do not believe that this
approach adequately accounts for variability due to normal operation in some cases because (for
example) the requirement to maintain a minimum pressure drop and liquid injection rate on a wet PM
scrubber will result in the reporting of deviations during low generating loads. The commenters provide
as another example the requirement to maintain sorbent injection rate at the rate established during the
compliance test and state that such a requirement may result in the unnecessary reporting of deviations
when these units fire lower pollutant-containing fuels. The commenters suggest that an alternative
approach for establishing a more representative set of normal control device operating ranges might be a
statistical analysis of historical operating data during which the control device was operating properly
(no malfunctions). According to the commenters, the resulting operating limits could be discreet upper
and lower bounds on certain operating parameters or a correlation between the control device operating
parameter and one or more boiler operating parameters. If operating parameters are required, variability
must be addressed. Therefore, one commenter recommends that the EPA should increase the averaging
period from 12-hour block averages to 30-day rolling averages.

Similarly, other commenters (17808, 17870, 18025) state that setting an unreasonable operating limit
that fails to reflect the full variability of the plant's operating conditions could damage the control
technology. For example, according to the commenters, the proposed rule requires a plant operator to
measure the voltage and current of each ESP collection field during each Hg, PM, and metals

77


-------
performance test, and the average of the three minimum hourly values would then be used to establish a
unit's site-specific minimum voltage and current operating limits for the ESP. According to the
commenters, maximizing power input and electric field strength will generally maximize ESP collection
efficiency and plant operators need a degree of flexibility to balance the power input to the ESP in order
to avoid serious damage to the system and downtime. The commenters note that power input to an ESP
is dynamically controlled by an automated voltage control system to maximize power levels while
avoiding sustained arcing or sparking between the electrodes and the collecting plates, which can
damage the ESP, including the transformer-rectifier and other components in the primary circuit and that
automatic voltage control varies the power to the transformer-rectifier in response to signals received
from sensors in the precipitator and the transformer-rectifier itself. According to the commenters, power
levels will vary depending on the amount of moisture in the air, accumulated ash levels, and other
factors, and as result, sustaining a minimum voltage and current level may not be possible or appropriate
at all times, and could damage the control technology.

8. Several commenters (17775, 17800, 17821, 17868) state that sources are in the best position to
determine what parameters and levels are consistent with compliance. According to the commenters, in
many cases, multiple parameter relationships or supplemental operational data will provide a higher
level of compliance assurance than the level that happens to be measured during a discrete performance
test. The commenters assert that this is particularly true for sources with a significant margin of
compliance (see EPA-HQ-OAR-2002-0058-0413, Attachment C at 4). The commenters recommend
allowing extrapolation of parameter data to preserve operational flexibility and avoid repeated testing.
According to one commenter, attempting to establish "worst case" test conditions on a scrubber or
multi-section ESP, where the possible combinations of parameters are numerous, would at the least be
difficult and could be impossible without a major research effort. The commenters assert that allowing
extrapolation of results avoids the necessity of repeated testing. The commenters note the a similar
approach has been used in CAM protocols for ESPs allowing extrapolation up to 1.25 times the recorded
value for measurements at less than 80% of the applicable limit. Several commenters (17775, 17800,
17820, 17821, 17868, 18428) recommend a CAM-like approach where once established parameter
would be monitored for deviations that would triggers corrective actions. The commenters note that
while the parameter range may in some cases be similar to the minimum values that would be
established under the proposed rule, allowing sources to respond with corrective action (rather than
simply record exceedances and report deviations) achieves the intended result without subjecting
sources to potential unreasonable enforcement.

Response to Comment 30: As noted above, the rule does not require monitoring operating limits where
a CEMS is used for the applicable standard. With respect to the need for variability in establishing
parameter limits because of load changes or changes in fuel, the rule provides for establishing different
operating limits based on different loads. Note that the ability to use parameter monitoring is a choice
made by the owner or operator. Where parameter monitoring is chosen, we believe that continuous
monitoring is needed to ensure ongoing compliance with this rule. As mentioned earlier, we require
performance tests to demonstrate compliance with emission limits; we then use operating limits to
ensure the source is operating similarly to how it was operating when it completed a successful
performance test. Operating limits are not direct measures of emissions but provide a measure of fuel
characteristics and control device performance and are established as enforceable operating limits
routinely in NESHAP standards. You are also able to petition the Administrator for approval of an
alternative monitoring plan under section 63.8(f) of subpart A of Part 63. This would include the
possibility of adapting existing CAM plans that may rely on different parameters. Finally, we agree with
commenters that collecting continuous data, transforming it to 1-hour averages, and then calculating a
30-day rolling average based on those 1-hour averages should address any variability concerns;

78


-------
therefore the rule now contains a 30-day rolling average for the PM CPMS parameter. For acid gas
emission limit compliance at liquid oil-fired units that use quarterly testing to demonstrate compliance,
you will propose a site-specific operating parameter monitoring plan for your facility that should include
the appropriate monitoring methods, QA/QC, and data reduction specifics for your unit. See the final
preamble for further discussion.

5. ESP total secondary electric power (TSEP) requirements (section 63.100010(h)(2)(iii)).

Comment 31: Several commenters (17402, 17715, 17775) express concern about proposed
requirements under section 63.100010(h)(2)(iii) for EGUs that have an operating limit requiring a total
secondary electric power (TSEP) monitoring system on an ESP. Commenter 17402 requests that the
EPA clarify how secondary power is calculated and if power is calculated on a field-by-field basis or
across the whole ESP. Commenter 17715 states that this parameter fails to take into account which
fields are being powered and where in the precipitator they are located. Commenter 17402 advises that
under the EPA's proposal, this monitoring will be problematic because ESP power and PM collection
efficiency vary by ESP configuration, fuel quality (coal sodium content), ash resistivity, number of
electrical and mechanical fields, plate alignment, gas flow distribution, gas temperature, particle size and
chemistry, rapper/vibrator settings, and air in leakage. The commenter has observed ESP power
fluctuations of 20 percent during steady-state operation, and during startup and shutdowns, the ESP
power shows even greater fluctuations-as high as 83 percent from high to low load. Commenter 17715
states that a TSEP minimum level set during a full load test is inadequate to assure compliance at all
loads.

Comment 32: Several commenters (17775, 17800, 17868, 18428) request that the agency review the
discussion on ESP performance in a report by McRanie Consulting entitled "Comments on the Proposed
Utility MACT Rule - Operating Parameters" (July 2011) that was attached to their comments, because
the report explains why proposed section 63.1001 l(b)(6)(iii) is flawed. According to the commenters,
Mr. McRanie explains that ESP power input simply is not directly related to PM removal performance
(particularly for the modern multi-section ESPs that are likely to be installed to comply with a proposed
MACT standard), and the total amount of power is not nearly as important as the location at which the
power is being applied in the ESP. The commenters refer to an attached report indicating that ESP
parameters are likely to have no relationship to PM emissions at units that also have a wet scrubber,
because wet scrubbers are highly effective in controlling high levels of PM from an ESP that is not
performing at the intended control efficiency.

Comment 33: Commenter 17775 points out that many EGUs have discovered while seeking the high
dust loads required under PS11 that even a fully disabled ESP may have little effect on resulting PM
concentrations when a wet scrubber is operating at expected efficiency. Commenter 17775 concludes
that EGUs should not be penalized for an ESP failure if another control, like a wet scrubber, is capturing
the resulting PM.

Comment 34: Commenter 17800 states that when an ESP is used in combination with a wet scrubber
the rule imposes operating limits on secondary power input to the ESP collection plates. (Section
63.1001 l(b)(6)(iii)). According to the commenter, the EPA's proposal is flawed. ESP power input
simply is not directly related to PM removal performance, especially with a wet FGD following the
ESP. According to the commenter, none of the ESP parameters are likely to have any relationship to PM
at units that also have a wet scrubber, since those systems also are highly effective in controlling high
levels of PM coming out of an ESP that is not performing at its intended control efficiency.

79


-------
Comment 35: Commenters 17402 and 17808 use the example of normal ESP operation to explain why
the proposed parametric constraints could lead to increases in emissions or damage to the control device.
Commenter 17402 states that current, voltage, and total power are constantly reacting to boiler ash
conditions, flue gas temperature, flue gas moisture, coal quality, coal moisture, flue gas flow rate, ESP
cleanliness, ESP ash buildup, and fuel heat input. Commenter 17402 states that operating limits for
control equipment based on a point-in-time stack test do not recognize the balancing act that plant
operators perform daily to meet emission limits for not just HAP but all of the pollutants that are
currently regulated.

Comment 36: Commenter 17808 agrees with the principle underlying the proposed parametric
constraints on ESPs (i.e., that maximizing power input and electric field strength will generally
maximize ESP collection efficiency), but the commenter states that plant operators need a degree of
flexibility to balance the power input to the ESP in order to avoid serious damage to the system and
downtime because the power input to an ESP is dynamically controlled by an automated voltage control
system to maximize power levels while avoiding sustained arcing between electrodes and collecting
plates, which can damage the ESP; automatic controls adjust power in response to various sensors so
that normal power levels will vary depending on the amount of moisture in the air, accumulated ash
levels, and other factors. Commenter 17808 advises that this core functionality of ESPs may make the
proposed constraint for minimum voltage and current level inappropriate at certain times, and such a
requirement could damage the control technology.

Comment 37: Commenters 17808 and 17725 recommend that the final rule require proper operation of
the plant's pollution control equipment and appropriate parametric monitoring without establishing
numeric operating limits.

Comment 38: Commenter 17772 notes that total secondary electric power is a poor measure of ESP
performance. According to the commenter, this is especially true if it is tied to a minimum power
concept. The commenter states that on some days particulate loading to an ESP can be low, yielding a
lower number of fly ash particles to be charged. Moreover, according to the commenter, during periods
of low loading, total power can go down to levels lower than that which may have been observed during
the compliance test day if a larger number of fly ash particles were being sent to the ESP during the
compliance test; voltage may still be high, but because current is lower; total power is lower, and that
does not mean that the ESP is operating poorly relative to the compliance test levels. In such instances,
according to the commenter, it is either not possible to maintain a high level of current or, if possible, it
may be a waste of energy. Commenter 17772 believes that the requirement to maintain "the 12-hour
average secondary power input at or above the operating limits established during the performance test"
as required in section 63.10011 (c) is inappropriate and is not a true indicator of the operating condition
of the ESP.

Comment 39: Commenter 17821 states that the secondary power approach for ESPs simply does not
work and this fact is easily demonstrated by real world operating experience. According to the
commenter, precipitator power will vary depending upon a number of factors, including operating
conditions, coal quality, load, and other factors. According to the commenter, this is a phenomenon that
the commenter routinely sees in the operation of its own units. The commenter states that precipitator
operation is complicated even further with the addition of sorbents into the flue gas for emissions control
and that different fuels may require more or less dry sorbent injection, and those fuels will also cause
changes in precipitator operation. According to the commenter, these changes will likely result in a
change in the total secondary power to the ESP but not necessarily a reduction in removal efficiency.
The commenter states that the proposed rule should instead require site-specific plans to be developed

80


-------
for each EGU. According to the commenter, because ESP designs vary greatly, the parameters selected
may include total percent of fields in service, or a limit on the number of fields in a given train that may
be out of service at one time.

Comment 40: Commenter 17881 states that under Table 4 - Operating Limits for EGUs for ESPs, the
requirement for ESPs conflicts with section 63.1001 l(b)(6)(iii), which does not impose a caveat on the
ESP operating parameters such that it only applies to units with wet controls. The commenter further
notes that the power input is calculated as the three-run average and not the lowest single run.

Comment 41: Commenter 17925 states that monitoring of total secondary power of the ESP should be
optional if more representative parameters can be shown to be acceptable. According to the commenter,
the EPA publication EPA-340/1-83-017 states that the efficiency of an ESP is directly related to the
power delivered to the gas stream (watts/1000 acfm, page-171) and supports the notion that total
secondary power of an ESP could be the monitoring parameter for ESPs. According to the commenter,
however, using secondary power of each ESP operating field as the parameter, or total secondary power
of the entire ESP, requires that combustion units maintain the same power level target parameter at
lower fuel loads, which is difficult to accomplish. The commenter asserts that targeting of secondary
power in each field is unnecessary for successful monitoring and compliance. The commenter
recommends monitoring of total power to the ESP as a more practical parameter to work with than
power to the individual fields if adjusted for changes to unit operating rate. To account for lower ESP
power at lower operating fuel loads, the commenter suggests that the ratio of watts/1000 acfm should be
monitored and targeted. According to the commenter, since the gas flow rate is generally proportional to
the fuel firing rate, a surrogate for gas flow is fuel input rate. Therefore, according to the commenter, an
alternate surrogate for total ESP secondary power when the fuel is, for example, coal, would be total
secondary power divided by total coal input rate or watts/pound. According to the commenter, this total
secondary power to fuel ratio parameter has been used in the past at combustion units to meet MACT
requirements for ESP parameter monitoring and has been found to be acceptable both on a technical and
regulatory basis. The commenter asserts that monitoring and setting the operational target for an ESP
using this parameter ratio is superior to monitoring secondary power per field or even total secondary
power to the entire ESP unit because it dampens the impact on the signal of unit operating rate.

Comment 42: Commenter states that difficulties can be encountered when attempting to set operating
parameters entirely based on stack testing. According to the commenter, experienced equipment
operators would not be willing to run equipment at potentially unsafe operating conditions that are not
considered representative of normal operation, simply to provide set operating parameter ranges. The
commenter also notes that while ESP power, a parameter that must be monitored as described in the
EGU MACT rule, at minimum power, provides good ESP performance information, it is not necessarily
a reliable indicator of poor performance. The commenter states that lower power generally means poorer
performance, but ESPs are segmented into many electrical sections and the power consumption for each
section relative to its physical location can mean that similar power consumption scenarios can provide
different levels of emissions control. According to the commenter, this type of information would be
difficult to verify through stack testing, considering other variables like fuel quality, varying loads, etc.,
but can be easily evaluated using an ESP performance model. The commenter notes that where CEMS
are available that information should be used to evaluate excess emissions.

Comment 43: Commenters 17775 and 17790 recommend the use of boiler models or emissions models,
in addition to manufacturer specifications, to set up acceptable operating ranges. The commenter notes
that, for example, in the CAM Program, the use of models and manufacturers information is allowed and
that in the guidance document "Compliance Assurance Monitoring (CAM) Protocol for an Electrostatic

81


-------
Precipitator (ESP) Controlling Particulate Matter (PM) Emissions from a Coal-fired Boiler", use of ESP
models is recommended, and the commenter refers to page 5 of this document: "An approach that has
been demonstrated to provide a reliable indication of ESP performance is the use of an ESP performance
computer model calibrated using site-specific data and other data in conjunction with continuous opacity
data." Commenter 17775 states that the EPA should include in this rule an option similar to subpart Da
to use an ESP model on a daily basis to assess proper operation of an ESP in between performance tests.
According to the commenter, if the use of the model as required under subpart Da is sufficient to assure
compliance with the NSPS, it also should be sufficient under subpart UUUUU.

Response to Comments 31 - 43: Although the EPA notes some owners and operators have been
successful in using parameters to model ESP performance, the comments are inapplicable, for the rule
no longer requires parameter monitoring or operating limits for PM control devices.

6. Parametric limits for wet scrubbers (section 63.20011(b)(6)).

Comment 44: Commenter 17775 expresses concerns with the proposed parametric operating limits for
wet scrubbers at section 63.2001 l(b)(6)(i) and (ii); the commenter states that the proposed parametric
ranges established during performance tests lack a sufficient relationship with actual emissions over
normal operating ranges. The commenter references an attached report indicating that the normal pH in
a scrubber can vary significantly, but that as long as pH is within the normal range, its impact on
scrubber efficiency is minor. According to the commenter, however, if pH falls too low, metal
components can corrode, and if pH is too high, calcium sulfate deposits can develop. The commenter
states that as a result, operators monitor pH to ensure it is within the desired range and react to bring pH
back within that range if necessary. According to the commenter, operators have no incentive to allow
pH to fall outside the normal range. Commenter 17775 concludes that requiring operators to artificially
maintain pH to the level during a performance test is not a useful requirement.

Comment 45: Commenter 17821 states that pH measurement is not sufficiently related to acid gas
removal to apply enforceable limits. According to the commenter, the measurement of pH in an FGD
system is only a small part of the very complex chemistry in an SO2 removal system; the pH is mainly
used to prevent scaling of the modules. The commenter asserts that maintaining a higher pH does not
guarantee any additional removal of SO2, HC1, or other acid gases, but that higher pH values will lead to
scaling, which may lead to other operational problems. The commenter states that as an example, scaling
can cause plugging of mist eliminators, which in turn could potentially increase particulate emissions.
The commenter notes acid gases such as HC1 and HF are strong acids and very readily dissolve in water,
whereas SO2 is a weak acid, which explains why its transport from the gas phase into the liquid phase in
a scrubber occurs at a slower rate. According to the commenter, the EPA acknowledges that acid gases
are likely to be removed in typical FGD systems due to their solubility or their acidity (or both). The
commenter states that the conclusion is that HC1 and other acid gases are very effectively removed by
contact with water in a wet FGD system, so effectively removed in fact, that high removal rates will be
maintained even at pH levels below those used for effective SO2 removal, provided there is an adequate
recirculation flow. Instead of requiring FGDs to maintain a specified pH, the commenter suggests that
the rule should require that sites develop site specific plans that incorporate parameters that more
appropriately describe the operation of an FGD system. For example, the commenter suggests that
stations may elect to use parameters such as number of absorber recirculation pumps in service,
measured SO2 levels from CEMS measurements, or other facility specific measurements.

Comment 46: Commenter 17821 states that there is ambiguity in what the EPA wants to restrict. There
are two potential liquid flows in an FGD system; the first is the amount of chemical reagent that is added

82


-------
to the FGD module. According to the commenter, this is most commonly either a water slurry of lime or
limestone, the concentration of this material varies depending upon the operating condition, and the
mass flow rate of reagent is directly proportional to the mass of SO2 that is removed in the scrubber per
unit of time. According to the commenter, because the chemical reagent must be added at the proper
stoichiometric ratio, it is totally inappropriate to require a fixed feed ratio based on full load, worst-case
conditions; doing so will damage the FGD system and will render it ineffective for removing S02 and
other acid gases. As a result, the commenter concludes, the EPA is not attempting to regulate lime or
limestone reagent flow but instead seeks to regulate the total amount of liquid flow that is recirculated in
the module and sprayed into the flue gas stream. The commenter states that FGD modules use one or
more recirculation pumps to remove large volumes of FGD liquor from a reservoir in the bottom of the
module and spray it into the flue gas; these are high volume, centrifugal pumps that run at a single
speed. According to the commenter, most sources do not normally install flow meters in this situation,
and installing monitors in this application will not achieve the accuracy that the EPA specifies. The
commenter states that most new FGD installations utilize fiberglass reinforced piping (FRP) to transport
recirculation flow through the FGD module. According to the commenter, the FRP increases reliability
but is not conducive to external flow measurement techniques, and further complicating the matter is
size of the piping—the larger the diameter, the more difficult to obtain accurate readings. According to
the commenter, flow meters with the proposed accuracy of 2 percent are not practical for these FGD
installations. The commenter states that internal flow meters may be able to provide more accurate
readings immediately after installation, but the harsh conditions of the FGD will cause them to lose
accuracy quickly. In any event, according to the commenter, the length of FGD piping is short compared
to its diameter, and has many elbows and fittings, so it typically does not have enough straight lengths of
pipe to allow for the installation of highly accurate flow monitors. According to the commenter, even if
the recirculation flow rate could be measured to the desired accuracy, those measurements would not tell
the whole story. The commenter states that in a properly operating FGD system, the density of the
recirculation flow has to change with different operating conditions to maximize removal efficiency and
that when the density of a material being pumped increases, the volume of flow through a centrifugal
pump decreases. According to the commenter, FGD operators do not have control over this recirculation
flow because the piping systems do not have any sort of flow control valves. In short, the commenter
states, a recirculation pump is either on or off, and . therefore attempting to maintain volumetric flow
rates at a level established during the performance test will cause operators to chase process parameters
that would be counterproductive to achieving the best removal efficiency.

The commenter states that the EPA should also realize that when an EGU reduces its load, the volume
of flue gas passing through the FGD system decreases, but the amount of recirculation flow stays
relatively constant. According to the commenter, this results in an increase in the liquid to gas ratio,
which in turn promotes even more efficient scrubbing. Therefore, the commenter states, the more
appropriate metric would be to require that EGUs be required to maintain a minimum recirculation flow
to gas ratio instead of a simple minimum liquid flow rate. According to the commenter, that would best
be accomplished by requiring a minimum number of pumps to be kept in service at all times as
demonstrated during the performance test, and as a result, flow monitors would not be needed or
installed. In addition, the commenter states, it would be appropriate for the EPA to require sources to
demonstrate that the flue gas is indeed going through the scrubber module and is not being bypassed.
According to the commenter, these parameters will adequately ensure that the FGD operation will
properly remove the acid gases that will be regulated in the final rule.

Comment 47: Commenter 17821 states that restricting FGD modules to minimum pressure drop
requirements has no benefit. According to the commenter, in the proposed rule, stations would be
required to measure differential pressure across the FGD module(s) during the annual performance tests,

83


-------
and maintain a 12-hour pressure drop value above the average measured in the performance test. The
commenter asserts that like other limits the EPA has proposed, this limit fails to account for reduced
load operation. According to the commenter, FGD pressure drop is a direct function of the amount of
flue gas flow through the module, and thus is directly related to boiler load. In a case where velocity
doubles, the commenter stats, the pressure drop would quadruple. The commenter asserts that the
reverse is also true, in that as the load drops, the scrubber pressure drop would also decrease. According
to the commenter, there are different types of FGD systems such as open spray towers, and units with
trays; however for all these designs, a reduced pressure drop at lower load does not by itself indicate a
reduced level of HAP capture in a FGD system. In fact, according to the commenter, the scrubber
performance is more likely to improve at reduced load because there is a higher ratio of liquid flow to
flue gas flow; pressure drop is more a function of mist eliminator cleanliness than acid gas removal. The
commenter notes that there may be steady state systems, such as waste combustors, where measuring
pressure drop could be useful. The commenter asserts that instead of using pressure drop to demonstrate
compliance, the EPA should require sources to develop site-specific plans to ensure the effectiveness of
the FGD for particulate removal and acid gas removal, which would then be subject to review by state
and local agencies and contain more appropriate requirements such as maintaining a minimum number
of recirculation pumps in service, eliminating any bypasses of the FGD system, and periodically
inspecting internal components.

Comment 48: Commenter 18428 states the EPA's proposal to use pH, pressure drop and liquid flow-
rate as operating parameters for wet scrubbers is subject to the same flaws as the EPA's other proposed
operating limits — namely the lack of a sufficient relationship between the parameters measured during
performance testing and actual emissions. For example, the commenter states, because scrubber pressure
drop, liquid flow rate, and sorbent injection rate vary with boiler load, establishment of a limit based on
conditions during performance testing may tell the EPA little about actual emissions under other load
conditions.

Comment 49: Several commenters (17775, 17868, 17800) state that because scrubber pressure drop,
liquid flow rate, and sorbent injection rate vary with boiler load, establishment of a limit based on
conditions during performance testing may tell little about actual emissions under other load conditions.
Moreover, according to the commenters, when the EPA in 2008 considered the relationship between
liquid flow rate and PM in the context of the NSPS for electric steam generating units at 40 CFR subpart
Da, the EPA concluded that, at the level of the NSPS (i.e., 0.015 lb/MMBtu), PM emissions controlled
by an ESP were not particularly sensitive to the actual liquid flow rate (U. S. The EPA "Response to
Public Comments on Rule Amendments Proposed June 12, 2008 (73 FR 33642)" (Nov. 2008), U.S.
EPA-HQ-OAR-2005-0031-0284, at section 2.5.3).

Comment 50: Multiple commenters (17736, 17715, 17627, 17757, 18037, 18539, 19114) state that the
proposed rule lays out a method to establish site specific operating limits for various types of control
equipment in Tables 7 and 8. According to the commenters, for example, a wet scrubber would be
required to meet site-specific operating limits for pressure drop and liquid flow rate for compliance with
the PM standard. The commenters note that pressure drop and liquid flow rate may not be applicable to
all types of wet scrubbers and that the parameters may not be directly related to emissions. According to
the commenter, pressure drop is not a direct measurement of emissions and will naturally vary with load.
The commenters also suggest that liquid flow rate is also a function of load and the ability to measure it
accurately may be a problem. According to the commenter, the same issues are encountered when using
these parameters as a metric for demonstrating continuous compliance with the HC1 limits.

84


-------
Comment 51: Commenters 17775 and 17881 state operating limits are not direct measurements of
emissions or compliance. The commenters state that the proposed rule includes a requirement for wet
scrubber controls to maintain a pressure drop across the scrubber and a minimum liquid flow rate. The
commenters note that pressure drop is not used for control purposes, it is used to determine when
cleaning is required and is not necessarily accurate for assessing scrubber performance. Commenter
17775 states that the EPA must also recognize that Chiyoda scrubbers operate on a completely different
set of parameters than typical spray towers and that L/G is a more useful indicator for some types of
scrubbers. Commenter 17881 notes that under Table 4 - Operating Limits for EGUs for wet acid gas
scrubbers the requirement states to maintain a minimum pH. Controlling pH is a maintenance incentive
to prevent corrosion to major scrubber components. According to the commenter, the pH of the scrubber
vessel is an indication of the limestone slurry feed into the vessel, not the effectiveness of the slurry
spray.

Comment 52: Commenter 18023 states that pressure drop and liquid flow rate are not indicators of the
level of PM control being achieved by a wet scrubber. According to the commenter, the establishment of
operating limits for pressure drop and liquid flow rate would unnecessarily limit the range of key FGD
operating parameters. According to the commenter, pressure drop is not a universal indicator of the PM
control achieved by wet scrubbers (Commenter refers to Figure 26 in its comment). According to the
commenter, PM control by a modern jet-sparging type scrubber is not a function of pressure drop (three
figures are provided in the document showing PM control vs. pressure drop, liquid flow rate and liquid-
to-gas ratio). The commenter further notes that liquid flow rate is not a universal indicator of the PM
control achieved by wet scrubbers. In the commenter's experience, PM removal by a modern spray-
tower-type scrubber varies widely for different liquid flow rates. According to the commenter, PM
control is also not a function of liquid-to-gas flow rate.

With respect to HC1 scrubbing, the commenter states that HC1 is not easily monitored on a continuous
basis in flue gas. According to the commenter, pressure drop, liquid flow rate, and pH are not indicators
of the level of HC1 control being achieved by a wet scrubber, and the establishment of these operating
limits would unnecessarily limit the range of key FGD operating parameters. The commenter states that
HC1 control by modern jet-sparging type scrubbers is not a function of liquid submergence (or its
corollary pressure drop). Liquid submergence effectively changes the liquid-to-gas ratio of a scrubber.
The lack of correlation between HC1 emissions and liquid submergence suggests that there is also no
correlation between HC1 emissions and liquid flow rate.

Response to Comments 44-52: The comments are moot, as the rule no longer includes specific
requirements for parametric monitoring or operational limits for acid gas control devices.

7. Operating limits for low-emitting EGUs (LEEs).

Comment 53: Commenter 17402 states that operating limits are particularly inappropriate for low
emitting units because the commenter believes the operating limit procedures in the proposed rule are
repetitive, are counter to the purpose of the rule, and can result in facilities being deemed non-compliant
when controls are operating properly. The commenter states that these concerns are even more
applicable to LEEs, as the emissions associated with LEEs are dramatically lower than those of the rest
of the fleet. The commenter is concerned that slight variations in operating limits that deviate from the
operating conditions of the most recent performance test (that indicated the unit operates normally at a
fraction of the standard) may be deemed non-compliant and cause the unit to lose LEE status when in
reality the emissions never approached the MACT emissions limit. According to the commenter, this
result is not consistent with the impact of minor variations in operating limits, and the EPA should

85


-------
remove all operating limits from the rule, and in particular from application to LEEs, where such
standards are especially inappropriate.

Comment 54: Commenter 18426 states that the proposed rule includes a LEE definition for compliance
monitoring purposes. According to the commenter, for Hg, emissions less than 10 percent of the Hg
emissions limitation or less than 22.0 pounds per year on an existing unit may qualify for LEE status for
Hg. The commenter notes that for Michigan's Hg rules, a cut-off of 9 pounds per year, per unit was
developed as protective through the rulemaking process. According to the commenter, this could be a
smaller utility unit (25 MW to 100 MW) or a larger unit with low utilization where installing a Hg
CEMS is not feasible due to low emissions or economical due the unit utilization.

Comment 55: Commenter 17752 requests clarification on the criteria for qualifying for LEE with regard
to references to operating parameter limits in proposed section 63.10005(k)(3) and section 63.10006(c).
The commenter requests that the EPA clarify whether the use of ACI is permissible to qualify for LEE
and how operating limits would apply in that circumstance. The commenter also requests clarification
on fuel sampling as an operating limit and as a demonstration of compliance; it is not clear to the
commenter if the proposed rule intends for LEEs to comply with maximum fuel input levels under
section 63.10011(b) and the compliance provisions in section 63.10011(c).

Comment 56: Commenters 17775 and 17868 support the LEE option but find that the proposed LEE
requirements for "operating parameter limits" are not clear. Commenter 17775 finds the following
inconsistencies with respect to Hg testing periods that need to be addressed in the final rule:

1.	Commenters 17775 and 17868 state that the EPA should remove or appropriately clarify the
references to operating limits for LEEs. According to the commenter, proposed section 63.10005(k)(3)
and section 63.10006(c) refer to establishment and maintenance of "operating limits," but the provision
cited in section 63.10005(k)(3) for establishing such limits - section 63.10010(k)(3) - does not exist and
no other provisions address operating limits for LEEs. According to the commenter, proposed section
63.10021(a)(17) states that, for LEEs, results of emissions tests and fuel analysis - presumably the
monthly fuel analysis required under section 63.10006(c) - demonstrate continuous compliance, and the
provision does not mention operating limits.

2.	According to the commenters, the EPA's descriptions of the requirements for LEEs suggest they are
not required to establish or comply with operating limits. Specifically, the commenters say that the EPA
states: For existing units that qualify as low emitting EGUs (LEEs), conduct subsequent performance
tests for the LEE qualified pollutants every 5 years and perform fuel analysis monthly. Commenter
17775 states that if the EPA intended to require that LEEs perform monthly fuel analysis under section
63.10006(c), the EPA needs to make clear that compliance with the maximum fuel input levels is not
required and explain why it chose monthly testing. The commenter believes that analyzing fuel monthly
when the fuel supply or mixture has not changed seems unnecessary.

3.	Commenter 17775 states that if the EPA intended to require that LEEs establish and comply with
maximum fuel input levels as an "operating limit" under section 63.10011(b), rather than perform
monthly fuel analysis, the EPA needs to explain that the fuel analysis is an operating limit and not a
demonstration of compliance using fuel analysis under section 63.10011.

4.	Commenter 17775 also states that the EPA needs to remove the monthly fuel sampling and analysis
requirement in section 63.10006(c). According to the commenter, if the EPA intended to require that

86


-------
LEEs establish and comply with operating limits other than maximum fuel input levels, the EPA needs
to issue a proposal that explains the purpose of those limits and how they apply.

Comment 57: Several commenters (19536, 19537, 19538) states that the EPA should discard its "Low
Emitting Units" monitoring protocols. According to the commenter, monthly fuel testing does not assure
continuous compliance, and the EPA's variability analysis indicates HAP emissions are variable.
Monthly testing does not reveal any information about emissions between the monthly tests. According
to the commenters, the LEE monitoring should be expanded to require operational parameter monitoring
as required for all other compliance testing, and monthly fuel sampling further excludes emissions
during startup and shutdown. The commenters state that the LEE exemption should be eliminated, or the
threshold redefined to capture only those plants whose future emissions are assured to remain below the
prescribed limits. According to the commenters, if the EPA were to provide reduced monitoring for
certain low-emitting units, it should use a UPL for its thresholds, and if data from a unit indicates that
the 99% UPL of that unit's emissions are below 10% of the MACT limit, the EPA can be reasonably
assured that unit's future emissions will be below that threshold.

Response to Comments 53-57: The comments are inapplicable because the rule no longer requires
operating limits for LEEs.

8.	Oil-fired operating parameter comments.

Comment 58: Commenter 18025 states that for oil-fired EGUs the commenter recommends an
alternative approach that will better ensure proper operation of pollution control systems. Rather than
establishing fixed operating limits, the commenter recommends that the EPA require proper operation of
the plant's pollution control equipment and appropriate parametric monitoring without establishing
numeric operating limits.

Comment 59: Commenter 18428 states that it is not clear whether operating parameters and fuel input
limits in proposed section 63.10011(b) to apply to oil-fired units. According to the commenter, the
preamble statement suggests that operating parameters do not apply ("Except for liquid oil-fired
units,...we are proposing that you monitor during initial performance testing specified operating
parameters"). The commenter states that similar to LEEs, however, the EPA also suggests that liquid oil-
fired units must meet maximum fuel input limits as an operating limit. The commenter recommends that
the EPA should make clear in section 63.10011(b) what operating limits apply as well as explain why.

Response to Comments 58-59: The final rule clarifies that operating limits do not apply to these units,
with the exception of where: (1) a source elects to use a PM CPMS and an associated operating limit as
a means to ensure continuous compliance with an underlying filterable PM standard or non-Hg HAP
metals standard (or all HAP metals standard for liquid oil-fired EGUs); or, (2) a liquid oil-fired unit uses
quarterly testing to demonstrate compliance with acid gas emission limits (in which case the source must
develop a site-specific monitoring plan). See the final preamble for further discussion. Note that liquid
oil-fired sources may also use fuel moisture content analysis or supplier certification to show
compliance with the acid gas standards.

9.	Minimum sorbent injection rates.

Comment 60: Commenter 17821 states that there are multiple problems with the sorbent injection rate
requirements. DSI and ACI feed rates are normally correlated with other plant conditions, such as unit
load or flue gas flow, making a single fixed feed rate inappropriate. As an example, sorbent rates are

87


-------
normally set as a mass flow per volume of flue gas, such as a pound of sorbent per hundred thousand
cubic feet of flue gas. As a result, half the amount of sorbent would be injected when the flue gas flow is
reduced to half the flow rate. Interestingly enough, the same mass feed rate of sorbent may actually be
more effective at low flue gas flow rates, because it has more time to react due to the lower velocity.
However it will also increase the amount of byproduct material generated. Commenter states that the
problem of using one minimum flow rate for all conditions is the measurement of a sorbent has
problems. The material handling equipment for a dry solid such as Trona, ACI or other materials
whether milled or not, is not capable of precise weight measurements. Load cells are typically used to
gather injection rates, but because the material can clump or surge, short term measurements such as a
15-minute interval are too small to absorb all these fluctuations. Finally, DSI is also closely linked with
ESP performance. Injecting a "minimum" amount of sorbent over the entire operating range of a unit
could change the ash resistivity and thus impact precipitator performance, potentially making it
impossible to be in compliance with the operating limits for both sorbent injection rate and ESP total
secondary electric power. The commenter recommends that the EPA should allow sources to develop
site-specific correlations between sorbent injection rates and an appropriate to source parameter such a
flue gas flow or unit load. These rates would then be monitored over a longer time average such as 6-12
hours. In cases where CEMS are used to demonstrate compliance with HC1 or Hg standards, limits on
sorbent inject rates should not be required since the CEMS would be used to demonstrate compliance.

Comment 61: Several commenters (17622, 18037 and 18023) refer to the proposed compliance
approach for DSI systems (i.e., setting operational limits of reagent injection rate based on performance
testing at 76 FR 25031 and 25129). Commenter 17622 states that if operational limits consisting of
injection rates for DSI technology are going to be utilized to demonstrate compliance for a given level of
HC1 control, the reagent reactivity must also be considered an operational limitation. The commenters
advises that for Ca(OH)2, this could be accomplished by including reagent physical parameters such as
porosity and surface area in the operational limitation. Commenter 17622 also advises that for sodium
reagents, the physical properties of either Trona or sodium bicarbonate can impact the effectiveness of a
specific reagent for an acid gas control application; as an example, the particle size to which Trona is
milled prior to use is an important consideration. Commenters 18023 and 18037 state that the minimum
sorbent injection rate may be an appropriate operating limit for DSI and/or carbon injection; however,
the operating limit should be established in a way that accommodates operating over a wide load range
because it would not be prudent (i.e., it would pass unnecessary costs on to electricity customers) to
operate a sorbent injection system at the maximum injection rate when running at reduced load.
Commenter 18023 concludes that the operating limit should allow normalizing for gas flow such as
lb/MMacf or a calculated ratio. The commenter also states that dry scrubbers should have the option to
maintain the SO2 removal rate at or above the lowest 1-hour average rate during the most recent
performance test because this is more consistent with how dry scrubbers are operated in the industry.
Commenter 18023 concludes that any minimum sorbent injection requirement for DSI, carbon injection
and dry scrubbers should be set in a manner that allows for efficient use of sorbents across all operating
load ranges because minimizing sorbent injection is an important consideration both environmentally
and economically and injecting sorbent in excess of what is necessary (simply to meet an arbitrary limit
set by an emission test at one point in time) creates an additional potential waste stream that must be
managed. Commenter 18037 states that setting a minimum injection rate will potentially hurt units as
they attempt to balance their PM limit with the minimum injection of sorbent necessary to control Hg or
HCI. According to the commenter, sources should be able to maintain the flexibility necessary to meet
all of their emissions obligations.

Comment 62: Commenters 17775 and 17800 state that the EPA should consider and review data to
evaluate use of a load factor adjustment for those operating parameters that are load dependent. The

88


-------
commenters state that the EPA finalized a load factor adjustment in the Industrial Boiler MACT for
sorbent and carbon injection; specifically, the EPA revised the definitions of "Minimum sorbent
injection rate" and "Minimum activated carbon injection rate" to take load into account by multiplying
the "lowest hourly average" by a new term called the "load fraction" (see section 63.7575).

Comment 63: Several commenters (17627, 17715, 18539, 19114) take exception to the use of the
minimum sorbent injection rate parameter for dry scrubbers or DSI in Table 4 because they assert that
such a restriction removes all of the flexibility that a unit has to meet all of its obligations, and sorbent
quality may vary between suppliers requiring different injection rates per product. Additionally, they
assert, sorbent may be injected for reasons other than for HAP control; for example, during the periodic
MACT performance test an injection rate may be set based on temporary atmospheric conditions
requiring more injection for SO3 control; however proposed Table 4 would require the injection rate
based on SO3 conditions must be utilized until the next performance test for HAP compliance, despite
the fact that the injection rate was not related to HAP control.

Comment 64: Commenter 17805 states that according to the proposed rule requirements, ACI amounts,
or other control media, would be set at the highest operating load and a unit would not be able to reduce
the amount of product injected when running at lower loads and corresponding lower flue gas flows.
According to the commenter, this does not make economic sense and is wasteful to add more material
than necessary to control emissions.

Comment 65: Commenter 17881 states that Table 4 - Operating Limits for EGUs, the DSI sorbents are
likely targeting HC1/HF, not just Hg as suggested in this requirement. According to the commenter, this
paragraph should recognize that there may be multiple pollutant specific sorbents.

Response to Comments 60-65: These comments are inapplicable because the rule no longer requires
operating limits for sorbent injection.

10. PM CEMS operating limits (section 63.10011(d) and table 4, parameter 8).

Comment 66: Several commenters (17705, 17754, 17775) request that the EPA clarify how the PM
operating limits must be established because the provisions of proposed section 63.10011(d) are
inconsistent with the provisions for PM CEMS in proposed Table 4. Commenter 17775 adds that the
EPA has provided no data or discussion to explain how the average of three Method 5 runs would be
sufficient to capture variability under a various normal operating conditions. Commenter 17775 takes
exception to the use of the term "highest hour" in proposed Table 4 item 8 because it is not clear to the
commenter whether this term applies to Method 5 data or CEMS data. The commenter believes that item
8 makes no sense relative to Method 5 data, since runs are not measured in hours but in sample volume
(and runs will be more than one hour). The commenter also believes that item 8 makes no sense relative
to hourly PM CEMS data because at the time the operating limit is established because the values would
simply be output from the uncorrected CEMS.

Response to Comment 66: In consideration of the PM emissions limit and the potential burdens
associated with certifying a PM CEMS via PS 11, the agency decided to focus on the use of a PM
instrument not as a CEMS but as a CPMS. The PM operating limit for use in conjunction with a PM
CPMS functions in the same manner as parameter monitoring from other rules. The highest hourly
average of the PM CPMS signal produced over three test runs is used as the operating limit, and that
value becomes averaged over a rolling 30 boiler operating day average. The "highest hour" in Table 4 is
correct and refers to the Method 5 run data. Section 63.10011(d) is revised to be consistent with this

89


-------
approach. The final rule does provide for the use of a PM CEMS to determine compliance with the
filterable PM emission limit if the source elects to use this approach (see the final preamble for further
discussion).

11.	CPMS averaging times.

Comment 67: Commenter 17775 states that the EPA should clarify the averaging time of the required
parametric monitoring. According to the commenter, although the EPA proposes to define the minimum
operating parameters in section 63.10042 in terms of "90 percent" of the "test average" during the most
recent performance test, and to require compliance on a 12-hour average basis under Table 8, other
provisions and statements contradict that definition. For example, states the commenter, proposed Table
4 instructs sources to maintain parameters "at or above the lowest 1-hour average" during the most
recent performance test; proposed section 63.10021(c) requires determination of a "3-hour rolling
average of the CPMS data collected"; proposed section 63.10022(a) requires units using emissions
averaging to maintain the "3- hour average parameter values" for various control devices at or below the
operating limits established during the most recent performance test; and in the preamble, the EPA
describes operating limits as "[t]he average of the three minimum (or maximum) values from the three
runs for each applicable parameter ..." 75 FR 25,029/3. The commenter assumes that the proposed
definitions and the 12-hour average in Table 8 reflect the EPA's intent. The commenter asserts that the
EPA also must provide data to support achievability and enforceability of operating parameters under its
proposed definitions. The commenter states that although the EPA does not explain the "90 percent"
criterion in this rule, when the EPA previously promulgated a similar definition in the 2004 IB MACT,
the EPA explained that 90 percent value was intended to provide a range around the test average to
account for normal variations in the operation of the source and the control device (EPA Response to
Public Comments on Proposed Industrial, Commercial, and Institutional Boilers and Process Heaters
NESHAP (Feb. 25, 2004), EPA-HQ-OAR-2002-0058-0611 at 54). According to the commenter, the
EPA must provide data to confirm that the 10 percent allowed variance is sufficient. The commenter
states that before finalizing a rule that imposes parameters as enforceable limits, the EPA must analyze
data to determine what definition provides adequate flexibility.

Response to Comment 67: The rule retains two operating limits in the final rule: for a PM CPMS and
for site-specific parameters from liquid-oil fired EGUs that choose to comply with quarterly emissions
testing for acid gases. See the final preamble for further discussion. The rule plainly states the PM
CPMS operating limit averaging period as each rolling 30-day operating period. The limit is set based
on the highest 1-hour average monitor output signal during a successful performance test. That average
serves as a measure of ongoing control of the unit in accordance with the operations that exist during the
performance test, and is similar to how the Agency has established operating limits under a number of
NESHAP standards. The appropriate parameter, monitoring approach, and data reduction requirements
(including averaging periods as appropriate) for the liquid oil-fired units will be set forth in the source's
monitoring plan. See the final preamble for further discussion.

12.	Optional moisture measurement technique.

Comment 68: Commenter 17715 proposes an additional option be available for measuring moisture: if
the stack is saturated, a source should be able to use temperature, absolute pressure, and a psychrometric
chart to determine moisture; temperature and pressure transmitters can be calibrated with NIST traceable
equipment; during periods when the stack is not saturated, default factors listed in the rule could be
used.

90


-------
Response to Comment 68: While the rule does not contain the additional options mentioned by the
commenter, the commenter remains able to request use of such instrumentation via the general
provisions at section 63.8(f) of subpart A of part 63.

13.	Frequency of QA/QC requirements for parametric monitoring devices.

Comment 69: Several commenters (17716, 17725, 18014, 18498) state that sources that are required to
conduct control device parameter monitoring must follow prescriptive QA/QC requirements and
performance evaluation schedules as outlined in section 63.1 0010. According to the commenters, some
of these requirements are unnecessarily frequent, such as the need to check pressure taps at least once
each boiler operating day, and the requirement to conduct annual evaluations of ESP power monitoring
systems is excessive particularly for large ESPs with numerous electrical bus sections. The commenters
suggest that the EPA specify all operating parameter QA/QC activities and performance evaluations in
accordance with manufacturer's recommended procedures.

Response to Comment 69: In the final rule, the source owner or operator must prepare a site-specific
monitoring plan for its PM CPMS, and, for those liquid oil-fired sources that choose to conduct
quarterly acid gas emissions testing, for appropriate parameters to demonstrate that operations at the unit
remain consistent with operations during the performance test. See the final preamble for further
discussion. This plan identifies the QA/QC procedures the source will follow and calls generally for a
daily performance evaluation of some form for most monitoring devices as a basic QC check. No
specific QC checks have been prescribed in the rule; rather, the source owner or operator is able to
choose the specific method that will be used to fulfill this QC check in conjunction with developing the
site's monitoring plan.

14.	Consistency of rule with data gathered during the 2010 ICR.

Comment 70: Commenter 17775 believes that the EPA cannot require stack testing under conditions it
did not consider in the standard setting process. Neither does commenter 17775 believe that the EPA can
require EGUs to operate at a fixed load for 30 operating days. According to the commenter, the EPA
proposes to require that all "performance testing" be conducted at "maximum normal operating load
while burning the type of fuel or mixture of fuels that has the highest content of chlorine, fluorine, non-
Hg HAP metals, and Hg" (Proposed section 63.10007. The commenter states that the EPA also proposes
that it be able to request that performance tests be conducted under other representative conditions, and
that EGUs be required to provide records to determine those conditions upon request (proposed section
63.10007(f)). The commenter states that for EGUs using CEMS, the "performance test" runs for 30
operating days (proposed section 63.10005(a)). The commenter states that for these EGUs, the EPA
must recognize that it may not be possible to maintain "maximum" normal operating load for a full 30
operating days. According to the commenter, instead, the EPA should simply require representative
operation. The commenter states that because such sources are monitoring compliance continuously
after that point, there is no reason to require worst case testing conditions.

Response to Comment 70: The agency maintains that it has adequately incorporated variability into the
final standards in response to other comments on this issue.

15.	Frequency of stack tests.

Comment 71: Commenter 17736 states that bi-monthly stack testing imposes an unnecessary drain of
resources and will, inevitably, force units into non-compliance. The commenter states that an EGU

91


-------
electing to comply with the total or individual non-mercury HAP metal emissions limit (without CEMS)
is required to demonstrate continuing compliance by stack testing every two months and that stack
testing at such a high frequency is an unnecessary drain of resources. According to the commenter,
conducting six stack tests in one year is a grossly expensive, time consuming, and disruptive
requirement. The commenter maintains that the proscribed parameter limits should be eliminated and
replaced with provisions allowing facilities to work with states to develop site-specific compliance
plans, if deemed necessary, bi-monthly stack testing is especially excessive if/when the unit is subject to
any additional monitoring requirements.

Comment 72: Commenter 17775 states that proposed fuel input limits and frequent periodic stack
testing requirements are duplicative because under the proposed rule, the maximum time between stack
testing for non-Hg metals and HC1 (for units using stack testing to demonstrate compliance) is
approximately 60 days (i.e., every other month for EGUs with PM controls). The commenter states that
if an EGU plans to combust a new fuel type or mixture and that fuel exceeds the maximum metals input
level during the prior performance test, a new performance test is required within 60 days of combusting
that fuel (proposed section 63.10021(a)(4), (6), and (8)). According to the commenter, because testing
already is required every 60 days, the requirement to test following a revised maximum fuel input limit
is duplicative. However, the commenter states, given the notice and planning requirements for stack
tests, it also is not reasonable to require stack testing sooner. According to the commenter, current
operating parameters provide a reasonable assurance of compliance prior to the any new performance
test and requiring testing of new fuels, and stack testing in response to changes in maximum fuel input,
are more than sufficient to addresses any concern that a change in fuel warrants reexamination of those
operating parameters. The commenter contends that the EPA has not provided adequate justification for
such frequent stack testing, and therefore the final rule should require stack testing no more frequently
than annually unless such a test is triggered by a change in the maximum fuel input as a result of a
change in fuel type.

Comment 73: Commenter 17798 recommends, for PM, stack testing every 2 years or at a maximum on
an annual basis in conjunction with monitoring operating parameters. According to the commenter, for
units without pollution control equipment the source should perform continuous monitoring or stack
testing every 6 months. The commenter further recommends that the stack testing regime address
determining minimum and maximum operating parameters of control equipment under different
conditions to address variability. According to the commenter, for pollutants with emission limitations
(acid gases and Hg) the EPA should apply the same structure for CEMS and stack testing as discussed
here for PM requirements. The commenter states that also for these pollutants, testing and setting of
pollution control operating parameters should be applied only in conjunction with the stack test
compliance demonstration option. According to the commenter, these changes will streamline the
process, reduce cost, and achieve the same environmental result.

Comment 74: Commenter 17902 states that testing should be allowed on a less frequent 3-year or 5-
year basis when HAP emissions are significantly below the MACT emissions limits (as the EPA has
proposed in section 63.1 0006). The commenter states that additionally, EGUs that participate in an
emissions averaging plan should not be restricted from reduced performance testing if the relevant HAP
emissions from the units in combination are in fact below the percent thresholds of the relevant MACT
limits.

Comment 75: Commenter 18426 states that emissions testing required monthly or every other month
depending on the unit and pollutant specified in the proposed rule is excessive and inconsistent.
According to the commenter, if an acceptable parametric monitoring system is developed, emissions

92


-------
testing once a year or every other year should be sufficient, and even if no emission control system is in
place, unless a significant change in the fuel characteristics occurs, emissions testing once a year or
every other year should also be sufficient. The commenter recommends that at a minimum, the EPA
should make the testing and monitoring requirements consistent for the units and pollutants.

Response to Comments 71 - 75: The agency agrees that fuel input and frequent periodic stack testing
requirements could be duplicative; therefore, the rule no longer requires fuel analysis for pollutants. The
rule requires quarterly emissions testing for units that choose to use emissions testing. In addition,
sources remain subject to underlying parameter monitoring that applies to many of these units, through
Compliance Assurance Monitoring (40 CFR Part 64) or other existing regulatory programs. For liquid

011-fired	units that choose to use emissions testing, there is an additional requirement for continuous
parameter monitoring of the method of control for acid gases. See the final preamble for further
discussion. The quarterly stack testing period, coupled with underlying monitoring of control devices or
the additional monitoring for liquid oil-fired units, is expected to be frequent enough to ensure that a
unit's emissions control devices and processes continue to operate in the same manner as during the
previous stack test. If there are significant changes to the operation of the unit or the fuel, then a retest is
required to reconfirm that the source remains in compliance under the new operating circumstances.

16. Operating parameters during SSM.

Comment 76: Commenter 17886 states that during startup, shutdowns, and malfunction periods use of
established parameters set during performance tests would not be proper. The commenter notes that the
EPA has not addressed this concern in the proposal but should consider some best management practice
option during those periods.

Comment 77: Several commenters (17775, 18428, 17800) state that they are very concerned about the
potential for enforcement of operating parameter and opacity limits during periods of startup, shutdown,
and in the event of equipment malfunction. According to the commenters, the current proposal would
allow enforcement of deviations from operating parameter limits during periods of startup and
shutdown, when controls would not be expected to be operating at the same levels as during
performance tests. The commenters note that the EPA did assert in the preamble that SSM conditions
were taken into account by proposing use of 30 boiler operating day rolling averages and by the fact that
EGUs often use cleaner fuel during startup. According to the commenters, these assertions regarding
startup and shutdown are inapplicable to control device operating parameter limits, which are based on

12-hour	averages established during performance testing. In short, assert the commenters, the EPA has
made no allowance in its operating limits for periods of startup and shutdown but to the contrary, the
EPA has proposed to require sources to establish control device operating parameter levels that are
dependent upon load during periods of "maximum normal operating load," or other frequently used
loads, and then maintain those levels during other periods, including startup and shutdown. The
commenters urge the EPA to address these periods in another manner, for example by establishing
simple work practice standards in lieu of operating parameters.

Response to Comments 76 and 77: As mentioned elsewhere, the final rule no longer requires
continuous measurement of operating parameters, except when PM CPMS are used and when a liquid
oil-fired EGU without an FGD uses a combination of emissions testing and continuous operating
parameter monitoring to demonstrate compliance. Because work practice standards apply during periods
of startup and shutdown, the EPA has clarified in the final rule that the PM CPMS operating limit does
not apply during such periods. Instead, for coal and other solid fuels, the work practice standards for
such periods will apply, together with the monitoring and recordkeeping required to document

93


-------
compliance with those work practices. The final rule also provides for sources to apply affirmative
defense of excess emissions including deviations from PM CPMS measured operating limits relative to
process malfunctions.

17.	Operating limits based on total PM.

Comment 78: Commenter 17402 states that they support operating limits based on total PM and not
filterable PM. The commenter believes total PM is a more complete, more flexible, and better protective
standard. The commenter asserts that that there is too much variability with PM CEMS technology for
the operating limit to be set, given the high level of uncertainty involved in the test. Recognizing that
continuous condensable PM monitoring technology does not exist, the commenter's preference is to
preserve the flexibility allowed in choosing to reduce condensable PM or filterable PM by setting the
operational filterable PM limit based on the difference of the total PM limit and condensable PM
measured from stack testing (i.e., filterable PM (operational) = total PM limit (0.03) - condensable PM
(performance test)). The commenter believes this approach will provide flexibility and would address
both variability concerns with testing, fuel supply and operations.

Response to Comment 78: Given our decision to use a filterable PM standard as the PM emission limit
under this rule, this suggested approach would not be appropriate. Moreover, the operating limit
established for the PM CPMS is just that - an operating limit, and not a PM limit (filterable or total), and
does not require the source to present the monitor output in terms of PM.

18.	Request for clarification on multiple load testing (section 63.10007).

Comment 79: Commenter 17316 requests clarification on proposed provisions for multiple load
performance tests at section 63.10007 to establish load-specific operating limits. The commenter states
that it is not clear which operating limits are re-set following a performance test or whether a new
performance test program erases all previous operating limits, or only those operating limits for loads at
which testing was repeated. For example, the commenter asks if a unit initially conducted performance
testing at 3 loads: 100 percent, 75 percent and 50 percent, but for the next annual test cycle, only
conducted testing at 100 percent load to demonstrate compliance, whether the source could continue to
use operating limits established in the initial test program for the 75 percent and 50 percent load
levels. The commenter believes that it seems appropriate to allow continued use of operating limits for
load levels at which testing is not repeated, so long as test results at the maximum load level
demonstrate compliance.

Comment 80: Commenter 17767 states that control device operating parameters will vary according to
unit output and those parameter levels equating to compliance at high loads might be unacceptable or
unnecessary at lower loads. According to the commenter, absent a means to account for an acceptable
tolerance in these parameters, the rule allows for multi-load testing but fails to outline what load ranges
would be required, how to address operation between those loads and the costs of the testing regiment,
which would be high. The commenter recommends adding operating range tolerances as an appropriate
solution.

Comment 81: Commenter 17805 states that the section 63.10007 (Tables 5 and 7) contains compliance
demonstration requirements, and specifically, demonstration "through performance testing". According
to the commenter, these provisions essentially require utility units to develop parametric limits at
different operating levels and coal qualities. The commenter asserts that according to this section, stack
testing is to be performed while units burn coal with the maximum concentration of HAP constituents,

94


-------
but units would still have to ran at normal operating load. The commenter does not believe this would be
possible since the commenter has observed that coal with the maximum HAP concentration
characteristics generally contains lower heat content. Therefore, the commenter asserts, running a
performance test solely with coal having the higher HAP concentrations, and lower heat content, would
not allow a unit to attain normal operating loads; numerous stack tests would be required during a single
compliance period to determine parametric limits for each seam/quality or type of coal as proposed in
the rule and there could be multiple compliance periods in a year depending on a utility's chosen
compliance method. According to the commenter, this is burdensome. The commenter states that it
would be helpful for the EPA to review data showing HAP concentration variability by coal-type and
within coal-type before finalizing these monitoring requirements.

Comment 82: Commenter 17800 states that many units in the U.S. utility system are load following or
cycling units that change load on a daily basis and that many of the control device operating parameters
the EPA is requiring to be maintained will vary with load. The commenter states that to account for this,
the EPA suggests that EGUs obtain differing operating limits at loads other than the "maximum normal
load" required for stack testing by testing at those other lower loads (section 63.10007(c)). According to
the commenter, requiring EGUs to conduct performance tests at multiple loads is not practical or
reasonable, and the EPA has not considered the time or cost of that kind of extensive testing.

Response to Comments 79 - 82: The EPA finds these comments moot, for the rule no longer requires
operational limits except for those EGU owners or operators who choose to rely on PM CPMS to
demonstrate compliance. To the extent that those owners or operators choose to operate their units at
load levels other than normal operating conditions, those owners or operators will need to ensure that
their units remain in compliance with the emissions limits, which, as explained in the rule, may mean
that additional emissions testing and correlation will need to occur. With respect to the commenter's
example, if emissions producing characteristics had not changed since the original correlation testing
occurred, the commenter would be able to use the previous correlations for its operating parameters
when the unit's load changed.

19. Miscellaneous.

Comment 83: Several commenters (19536, 19537, 19538) states that the monitoring of operating
parameters as proposed under some scenarios does not assure continuous compliance with emissions
limits that are only measured annually or every 5 years. According to the commenter, the amount of
each HAP that is emitted ultimately depends on the amount in the coal, which is not tested more
frequently than monthly (or upon a change of fuel type) under any of the compliance scenarios.
Moreover, the commenter notes that the HAP content of fuel is highly variable even within fuel types.

Response to Comment 83: We understand that there is variability in the HAP metals content in coal
supplies and we believe that we were able to take that variability into account to a large degree with the
extensive database of emissions values and the statistical procedures used in establishing the floor and
the final emissions limitations. We believe that sources who demonstrate compliance with these limits
must apply the control measures including use of fuels that are consistent with the control measures
applied by the sources used in developing the limits. The commenter provided no information on how
the variability of fuel HAP metals content can vary significantly beyond that found in the database used
in setting the floor or to the extent that a source demonstrating compliance under the various compliance
monitoring measures allowed in the final rule will have undetected excess emissions.

95


-------
Comment 84: Commenter 17795 states that the EPA did not provide an explanation for selection of a
12-hour block average for operational monitoring. According to the commenter, the EPA should
maintain consistency among averaging periods for demonstrating compliance with emission standards or
operating limits; averaging operating parameter data over the same time period when employing direct
or surrogate continuous monitoring provides adequate assurance that equipment is operated and
maintained in compliance with standards or limits. According to the commenter, this also reduces the
data management and the quality assurance burden currently proposed with 12-hour block averaging
periods.

Response to Comment 84: This comment is moot given the changes in the final rule. The PM CPMS
will use a rolling 30-day average. Site-specific monitoring for liquid oil-fired units, if required, will
establish the appropriate averaging period based on the parameters being monitored.

Comment 85: Commenter 17740 states that it has significant concerns with the EPA's proposed testing
requirements for solid oil-derived fuel and coal-fired EGUs using total PM emissions as a surrogate for
non-Hg metals (see 40 CFR section 63.10006). The commenter understands that the purpose of this
testing is to ensure that the surrogate (i.e., PM) emission limit meets the direct HAP emission limits and
that the EPA reserves the right to adjust the surrogate limit. The commenter asserts that the EPA does
not have the authority to "adjust" surrogate emissions standards for individual units based on
performance testing. According to the commenter, if the EPA allows sources to comply with emissions
standards through surrogates, the surrogate emission standards also are subject to the requirements of the
CAA and cites National Lime //, 233 F.3d at 639 (holding that the EPA may use PM as a surrogate for
HAP if the "PM emission standards reflect what the best sources achieve — complying with CAA
section 7412(d)(3)"). The commenter stats that according to the MACT Floor Memo, the agency set the
PM MACT floor for existing units consistent with the requirements of the CAA. MACT Floor Memo, at
3 ("The existing-source MACT floors for PM, HC1, SO2, total non-Hg HAP metals, and individual non-
Hg HAP metals emissions were based on the top 12 percent of the total number of EGUs...").

According to the commenter, nothing in the CAA authorizes the EPA to subsequently review and revise
these standards on a unit-by-unit basis.

Comment 86: Commenter 17740 states that Congress specifically limited the EPA's authority to review
and revise emissions standards promulgated under section 112. Section 112(d)(6) instructs the
Administrator to "review, and revise as necessary (taking into account developments in practices,
processes, and control technologies), emission standards promulgated under this section..According
to the commenter, the CAA manifestly does not permit the agency to circumvent the requirements of
Section 112(d)(3) and set standards for specific units (citing e.g, Chevron U.S.A., Inc. v. Nat. Res. Def.
Council, 467 U.S. 837, 842-43 (1984) (holding that if Congress has spoken directly to the disputed issue
of statutory construction, "that is the end of the matter; for the court, as well as the agency, must give
effect to the unambiguously expressed intent of Congress"). According to the commenter, if, after
issuing a final rule, the EPA determines that a surrogate emission standard is no longer appropriate, the
agency must review and revise the standard in accordance with the express requirements of the
CAA. The commenter notes that the EPA's position deprives sources of much needed time to plan for
capital investments in control technology. The commenter states that a source has no way of knowing
whether its emission control measures are sufficient to comply with the EGU MACT if the EPA can
review and revise a MACT standard based on performance test results. According to the commenter,
even if a source makes substantial capital investments and achieves a proposed surrogate emission limit,
it may be forced to make additional investments in a short timeframe to achieve a new, individual limit
based on its performance test results. The commenter asserts that this circumstance creates substantial
regulatory uncertainty for affected sources.

96


-------
Response to Comments 85 and 86: The final rule no longer includes the use of PM as a site specific
emissions surrogate for HAP metals. Instead, the final rule allows the source to choose and comply with
one of three numerical emissions limits- total non Hg HAP metals, individual non Hg HAP metals or
filterable PM. The rule no longer requires the source to develop any surrogacy relationship to use one or
another emissions limit.

Comment 87: Commenters 17718 and 17881 note that section 63.10005(d)(7) states that initial
compliance through the use of CPMS can be determined using the average hourly PM, non-Hg HAP
metals, HC1, HF, or Hg concentrations obtained during the first 30-day operating period. In turn,
commenters note that continuous parameter monitoring systems, or CPMS, are defined at section 63.2 as
"Continuous parameter monitoring system means the total equipment that may be required to meet the
data acquisition and availability requirements of this part, used to sample, condition (if applicable),
analyze, and provide a record of process or control system parameters." According to the commenters,
they have been unable to identify any other place in the proposed rule where it is stated that CPMS can
be used for initial compliance, nor does the commenter understand how such monitoring systems could
be used for purposes of a direct compliance assessment with the emission limits in Tables 1 and 2 of the
proposed rule.

Response to Comment 87: The final rule in this section refers to "CMS", and is referring to continuous
emission monitoring systems that are used for direct compliance. Section 63.10005(c) discusses that you
may be required to establish an operating limit using a PM CPMS during an initial compliance
performance test period.

Comment 88: Commenter 17881 states that under section 63.10011 the concept of selecting the highest
minimum/maximum values across a series of performance tests is not congruent with multiple operating
limits for different scenarios.

Response to Comment 88: Given the simplification of the operating limit and parameter monitoring
provisions in the final rule, the EPA does not believe this comment remains applicable.

Comment 89: Commenter 17881 states that in section 63.10021(a)(1), there needs to be an allowance
for operation outside the initial operating limits during subsequent compliance tests for purposes of
widening the allowed operating limits without having to report a deviation (as long as the compliance
test results show compliance with the emission limit).

Response to Comment 89: The EPA disagrees. Given the 30-day averaging period, there is adequate
flexibility for a short term increase in PM CPMS output during a short term test without this type of
special allowance.

Comment 90: Commenter 17881 states under Table 4 - Operating Limits for EGUs, for IGCCs the
combustor temperature would likely be a better measure, as compared to electrical load (as a percent of
maximum output) which will float with ambient conditions.

Response to Comment 90: This comment is moot given the changes to the operating limits required
under the final rule.

Comment 91: Commenter 17881 states under Table 4 - Operating Limits for EGUs, with respect to PM
CEMS, that for concentration based emission or operating limits, it is normally appropriate to correct the

97


-------
concentration back to a reference O2/CO2 level for purposes of consistency (i.e., the diluent gas levels
will affect the concentration).

Response to Comment 91: There is no need to report the data from a PM CPMS in PM concentration
values.

Comment 92: Commenters 18014 and 17716 state that in Table 8, CPMS data is required to be reduced
to 12-hour block averages. However, the commenters assert that this requirement is not specified in
section 63.10010(h).

Response to Comment 92: The final rule has eliminated the parameters measured on a 12-hour block
average, and now requires only a 30-day rolling average for an operating parameter.

Comment 93: Commenters 18014 and 17716 state the limits for some operating parameters are also
internally inconsistent. The commenters provide an example that section 63.10042 defines the minimum
operating parameters limits (minimum scrubber effluent pH, minimum pressure drop, minimum
scrubber flow rate, minimum sorbent injection rate and minimum voltage or amperage) as 90% of
average value measured during the most recent performance test, but Table 4 states that the parameters
must be maintained "at or above the lowest 1-hour average" from the performance test. The commenters
recommend allowing sources greater flexibility in defining representative operating parameters.

Response to Comment 93: These comments are moot given the changes in the final rule, as discussed
above.

Comment 94: Commenter 18015 states that facilities should have the flexibility to use other parameters
than the ones identified in the rule. According to the commenter, for example, some units equipped with
wet FGD scrubbers have, as the primary parameter for control, density, not pH. The commenter notes
that the relative importance of various operating parameters can change depending on conditions and
therefore the rule should be flexible in order to account for other operating parameters and account for
variability in operating conditions. The commenter recommends that the alternatives should be
established through submittal of monitoring plans before testing and certifying CEMS.

Response to Comment 94: These comments are moot given the changes in the final rule, as discussed
above. The one circumstance in which the rule relies on flexible parameter selection is for liquid oil-
fired units that demonstrate compliance with emission limits for acid gases by conducting quarterly
performance tests. In that situation, the source must also develop a site-specific monitoring plan to
ensure that operating conditions remain consistent with conditions during the performance test. See the
final preamble for further discussion.

Comment 95: Commenter 17925 states that parametric monitoring should be applied as an action
indicator and not applied as a compliance monitor because they do not give a true indication of
compliance especially for multi-pollutant control configurations. According to the commenter, for
example, for PM emissions, the EPA has determined that ESP secondary current and baghouse leak
detection will be indicative parametrically of PM filterable emissions. However, the commenter states,
other equipment on units such as FGD systems (wet scrubbers) or DSI for ESP ash resistivity adjustment
also can serve to reduce filterable and condensable PM emissions. According to the commenter, in such
cases, a wide range of ESP secondary power rates and baghouse leak rates could be experienced while
PM emission limits are still achieved due to the impact of the other equipment. The commenter does
note that if parametric monitoring remains a compliance monitoring method, they agree with the

98


-------
approach of providing a variable range within the tested results. However, the commenter asserts that
some additional flexibility beyond a 10% range should be considered. According to the commenter, the
EPA does not explain how the 10% number was obtained and how the range would be used for
compliance.

Response to Comment 95: These comments are moot given the changes in the final rule, as discussed
above. See also response to Comment 30 in this section.

Comment 96: Commenter 17923 recommends that the operational limitations of the air pollution
control systems reference the manufacture recommendations. According to the commenter, the
methodology required by the proposed rule would significantly limit operational flexibility and
significantly increase the emissions testing required at affected facilities.

Response to Comment 96: These comments are moot given the changes in the final rule, as discussed
above.

Comment 97: Commenter 17718 states that the proposed regulatory language in 40 CFR 63.10006 (a),
(b), (d), (h) and (i), does not allow for process improvements. The commenter asserts that as written,
subsequent performance tests must be conducted "during the same compliance test period and under the
same process (e.g., fuel) and control device operating conditions." According to the commenter, process
improvements discovered after initial compliance testing could potentially allow for the same or better
control of emissions yet move the control device operating conditions outside of what was established as
the "operating limits" established per Table 4 and 7 of the proposed language. The commenter suggests
that the "same process and control device operating conditions" language be removed from these
regulatory sections. According to the commenter, this would be similar to language proposed in 40 CFR
63.10006 (e), (f), (g), (j), (k), (1), and (m) where testing under those "same conditions" is not required.

Response to Comment 97: These comments are moot given the changes in the final rule, as discussed
above.

Comment 98: Commenter 19033 states that section 63.10010 (h)(2)(i) is overly prescriptive with
respect to the minimum acceptable criteria for liquid flow monitoring. The commenter asserts that the
+/- 2 percent accuracy (section 63.10010 (h)(2)(i)(B)), is excessive, given the purpose for which liquid
flow monitoring is intended (verification that the scrubber is operating in a manner similar to the level at
which it operated during the performance test). The commenter points out that in its current Title V
permit the liquid input in based on supplied pump curves, which indicate flow as a function of pump
motor amperage. The commenter asserts that the proposed regulation also does not take into account that
there could be issues with spray patterns as nozzles wear over time. According to the commenter, liquid
flow measurements would not take that effect into account and would thus not be an accurate indicator
of pollutant removal. The commenter estimates that $250,000 would be needed to add the liquid flow
measurement and associated data acquisition systems needed to meet section 63.10010 (h)(2)(i)(B) and
that such an expenditure is not justified. The commenter agrees with the concept outlined in the July 29,
2011, comments letter provided with respect this proposed regulatory action by Thomas Easterly,
Commissioner of the Indiana Department of Environmental Management, i.e.

"Indiana asks that States be allowed maximum flexibility to develop alternate compliance
plans that afford the regulated community opportunity to assure timely compliance, while
also assuring that consumers are not adversely affected."

99


-------
In concert with the sentiment expressed by Commissioner Easterly, the commenter recommends that
states be provided the flexibility to approve liquid flow monitoring and other portions of the
required CPMS monitoring plan. To that end, the commenter recommends that section 63.10010
(h)(2)(i) be amended as follows: (i) If you have an operating limit that requires the use of a flow
monitoring system, you must develop a flow monitoring plan in consultation with your state
regulatory agency. The plan must be approved by the agency in advance of the initial compliance
demonstration requirements in (A) through (D) of this section.

Response to Comment 98: As discussed elsewhere, the use of operating parameters is no longer
required in the rule except for those associated with use of PM CPMS or those associated with use of
liquid oil-fired units whose owners or operators choose acid gas emissions testing and must provide
continuous parameter monitoring of their flue gas desulfurization systems. Where operating parameters
are used, the rule does not prescribe minimum quality assurance or control specifications; in concert
with the commenter's suggestion, these specifications are left to the EGU owner or operator to choose
and follow.

Comment 99: Commenter 19033 states that 63.10010 (h)(2)(ii)(D) is overly prescriptive. According to
the commenter, EGU operators may have experience that pressure drop sensors may provide reliable
output at a less frequent cleaning frequency than daily and alternatively, systems equipped with an auto
purge system would not require the daily operator interaction of manually cleaning the sensors.
According to the commenter, this parameter is another candidate for negotiation between the state
regulatory agency and EGU owner. The commenter recommends that section 63.10010 (h)(2)(ii) be
amended as follows:

(ii) If you have an operating limit that requires the use of a pressure monitoring system, you must
develop a pressure monitoring plan in consultation with your state regulatory agency. The plan must
be approved by the agency in advance of the initial compliance demonstration requirements in (A)
through (F) of this section. The plan must include the recommended accuracy, and include a
recommended maintenance interval for adequate sensor cleaning if an auto purge system has not
been installed.

Response to Comment 99: These comments are moot given the changes in the final rule, as discussed
above.

Comment 100: Commenter 17821 disagrees with the EPA's unwillingness to delegate some key
responsibilities to state and local agencies. The commenter states that in section 63.10041, the EPA
defines who is responsible for implementation and enforcement of this subpart: "In delegating
implementation and enforcement authority of this subpart to a state, local, or tribal agency under 40CFR
part 63, subpart E, the authorities listed in paragraphs (b)(1) through (4) of this section are retained by
the EPA Administrator and are not transferred to the state, local, or tribal agency; however, the U.S.
EPA retains oversight of this subpart and can take enforcement actions, as appropriate.

1.	Approval of alternatives to the non-opacity emission limits and work practice standards in
§63.9991(a) and (b) under § 63.6(g).

2.	Approval of major change to monitoring under § 63.8(f) and as defined in § 63.90, and approval
of alternative operating parameters under §§ 63.9991(a)(2) and 63.10009(g)(2).

The commenter strongly recommends that approval of alternatives to work practice standards and
alternative operating parameters be delegated to the state or local agencies for multiple reasons.

100


-------
According to the commenter, first, the state and local agencies are in a much better position to review
and access the merit of changes requested by individual operators; while it can articulate direction for
how to approve these requests, the EPA does not have the unit specific knowledge to understand and
evaluate the rationale for the requested changes. Second, the commenter states, the EPA has in this
proposal, done an inadequate job in developing operating parameter limits for the wide diversity of
EGUs. According to the commenter, because of the wide variety in EGU construction, control
equipment, and operation, it is unlikely that the EPA can develop a one-size-fits all approach that will
properly apply to the entire industry, and as a result, state and local agencies that are more familiar with
each source should be allowed to make those decisions. Finally, the commenter anticipates that there
will be a large number of these requests and that restricting approval to the EPA will create a terrible
delay in their approval that will put sources at a compliance risk.

Response to Comment 100: The EPA disagrees. Under implementation of the NESHAP program, the
EPA routinely retains the approval authority over these issues. There is nothing so unique within the
EGU sector as compared to all other industries to take a different approach under this rule.

Comment 101: Commenter 17752 requests that the EPA provide guidance on how to operate a
baghouse to obtain the three different PM concentrations.

Response to Comment 101: The comment is moot, as the rule no longer requires control device
operational parameters to be monitored.

101


-------
5A05a - Testing/Monitoring: Operating parameter monitoring (bag leak detection systems)

Commenters: 17704, 17716, 17725, 17737, 17775, 17868, 17871, 18014, 18498

Comment 1: Several commenters (17716, 17725, 17775, 17868, 18014, 18498) recommend that the
EPA remove the requirement to comply with the procedures in EPA-454/R-98-015. According to the
commenters, the referenced document is based on operating and maintenance procedures for a specific
type and model of bag leak detector (BLD) and is inadequate for many BLD systems (BLDS). The
commenters state that the definition of BLDS clearly allows use of a variety of technologies, including
electrodynamic, light scattering, and light transmittance. According to the commenters, the required
guidance document excludes all other technologies (e.g., light scattering, light transmission, optical
scintillation, and electro-dynamic devices).

Comment 2: Commenters 17775 and 17868 request clarification regarding the applicability of the
requirements for fabric filters. The commenters state that although several provisions suggests that
BLDS are only required if an EGU "chooses" to demonstrate compliance using a BLDS and cite, as an
example, proposed section 63.10011(b), other provisions appear to require any EGU with a fabric filter
to employ a BLDS along with any other applicable operating limits (citing Proposed Tables 4-8).
According to the commenters, the EPA should issue a proposal that makes clear when a BLDS would be
required and to justify that requirement.

Comment 3: Commenter 17704 states that if there is any redundancy such as BLDS for units with
fabric filters choosing to comply with PM CEMS, the requirement for the BLDS should be removed.

Comment 4: Commenter 17775 states that the recording alarm time in 1-hour increments is
unreasonable. In the case of a broken bag, the most common baghouse failure, alarms can usually be
cleared in only a few minutes by removing a single compartment from service.

Comment 5: Commenter 17737 strongly objects to any requirement to use BLDS to demonstrate
compliance. The commenter has been operating these devices on two of its units, and they have proven
to be extremely susceptible to false alarms. According to the commenters, on numerous occasions
(sometimes multiple occurrences in one day) the BLDS have indicated an alarm, following which an
investigation reveals no problems relating to particulate emissions or control equipment, and often, the
condition is rectified simply by cleaning the probes. According to the commenters, these false alarms
add to operational costs and keep plant personnel from their regular duties. The commenter suggests the
use of opacity measurement in place of PM CEMS or BLDS as compliance assurance monitors. The
commenter notes this would be similar to the requirements of 40 CFR 60.48 Da. According to the
commenters, opacity monitors have proven to be reliable in detecting changes in PM emission levels
which could trigger an operator investigation of potential malfunctions and take appropriate corrective
action. According to the commenter, because there is no reliable numerical correlation between PM
emissions and opacity, the opacity monitoring (and the same holds for BLDS, should an operator elect to
use them) should be used solely as an indicator and not for compliance. The commenter provided a
CAM example using opacity as the indicator and states that such an approach is sufficient to
demonstrate continuous control of PM emissions and should be suitable for continuous compliance with
the MACT standard for non-Hg metals especially when a control device with efficiencies above 99.5
percent is used for PM control, such as a fabric filter.

Comment 6: Commenter 17871 states that nearly all units are required to install a continuous opacity
monitoring system (COMS), either as a result of the NSPS or through the NSR program. According to

102


-------
the commenter, in other rulemakings, the EPA has asserted that while COMS "cannot directly measure
PM emissions," a "properly calibrated and maintained COMS is sufficient to demonstrate long-term PM
control device performance, since the purpose of the monitoring is to demonstrate with reasonable
certainty that the PM control device is operating as well as it did during the PM emissions test used to
demonstrate compliance" (In re Newmont Nevada Energy Investment, LLC, PSD Appeal No. 05-04
(EAB 2005) (citing 70 FR 7905, 7908 (Feb. 16, 2005))). According to the commenter, where each unit
would be subject to comprehensive and duplicative monitoring schemes, the EPA should refrain from
requiring installation of an expensive CEMS that does not provide additional compliance certainty.

Response to Comments 1-6: The final rule does not require use of a BLDS for EGUs that employ a
fabric filter control device. We believe that continuous monitoring in the form of CEMS, sorbent traps,
or CPMS or that frequent emissions testing are appropriate to ensure ongoing compliance with this rule.
We also agree with commenters that some of the monitoring provisions in the proposal were duplicative
and unnecessary. In order to simplify and streamline the final rule, we have removed most operating
parameter monitoring from the final rule. We have retained the owner-defined operating limit
monitoring using a PM CPMS as an option to periodic emission testing.

The rule establishes the PM CPMS as an operating limit monitor and not a direct filterable PM emission
monitoring requirement that meets PS11 requirements. While we recognize the importance of continued
control device performance to ensure emissions minimization, we also are aware that other rules that
apply to these units - including but not limited to the operating permits rule, the CAM rule, and the
NSPS - already require continuous monitoring in most cases. Those rules will remain in effect so the
need to impose additional operating limits monitoring or CEMS on those units is much reduced. For
these reasons, the final rule includes no requirements applicable to BLDS.

103


-------
5A06 - Testing/Monitoring: Application of Hg CEMS

Commenters: 17197, 17383, 17402, 17620, 17621, 17622, 17638, 17675, 17677, 17681, 17690, 17691,
17704, 17718, 17725, 17728, 17747, 17752, 17757, 17758, 17761, 17775, 17800, 17804, 17805, 17808,
17843, 17868, 17877, 17881, 17930, 18014, 18025, 18039, 18421, 18428, 18449, 18498, 18023

1. Requested clarifications and corrections.

Comment 1: Commenter 18014 advises that proposed sections 63.10010(f) and 63.1002l(h)(ii) have
contradicting requirements for quarterly accuracy determinations and daily calibration drift tests.

Comment 2: Several commenters (17728, 17758, 17775, 17868) state that all references in the proposal
to 40 CFR Part 60, Procedure 5 (e.g., section 63.10021(a)(14)(ii)) should be deleted because the
quarterly and daily requirements in Procedure 5 are duplicative of and conflict with some of the
proposed requirements in proposed Appendix A, and use of Procedure 5 is inconsistent with the EPA's
preamble statement that it considered and rejected using Procedure 5.

Response to Comments 1-2: The Procedure 5 references have been removed from the proposal so that
the Appendix A requirements, based on the CAMR approach, are used for Hg monitoring under this
rule, as indicated in the preamble to the proposed rule.

Comment 3: Commenter 17775 states that proposed Appendix A contains a number of provisions that
conflict with and/or duplicate requirements of part 63, subpart A, or with other proposed requirements in
subpart UUUUU:

1.	For example, according to the commenter, proposed section 7.2.2 requires 21 days notice of RATAs,
whereas 40 CFR section 63.9 requires 60 days notice of performance evaluations (a term that is
defined in section 63.2 to include RATAs).

2.	According to the commenter, proposed section 7.2.3.1 requires submission of a monitoring plan 21
days prior to initial certification testing or recertification testing, whereas proposed section
63.10000(d) requires submission of the monitoring plan 60 days before the initial "performance
evaluation."

3.	According to the commenter, proposed section 7.2.5.5 requires the owner or operator to submit a
compliance certification in support of each report based on reasonable inquiry, whereas proposed
section 63.10031(c)(2) requires that the compliance report contain a "statement by a responsible
official with that official's name, title, and signature, certifying the truth, accuracy, and completeness
of the content of the report."

4.	Finally, according to the commenter, the data validation provisions in section 5.1.3 conflict with the
out-of-control definitions in proposed section 63.10000(d)(6) and Table 9. Specifically, the
commenter asserts that Appendix A establishes data validation criteria for Hg CEMS in Table A-3,
which sets the acceptance criteria at <5.0 percent of span value or <1.0 [j,g/scm, proposed section
63.10000(d)(6) requires development and implementation of a site-specific monitoring plan that
"defines a continuous monitoring system that is out-of-control consistent with section 63.8(c)(7)(i),"
and Table 9 and section 63.10031(c)(9) also require reporting of periods during which a CMS was
"out-of-control, as specified in section 63.8(c)(7)." The commenter states that the term "out-of-
control" also is used to determine what data may be used to report emissions and what constitutes a
deviation of monitoring requirements under proposed section 63.10020(c) and (d) and that Section
63.8(c)(7)(i) defines "out of control" with respect to a "calibration drift test" as exceeding "two
times the applicable CD specification in the applicable performance specification of in the relevant

104


-------
standard." According to the commenter, this definition is inconsistent with Appendix A. The
commenter states that EPA must clarify its proposal regarding the definition of "out of control" and
must resolve these (and any other) duplications and inconsistencies, and where a requirement in
Appendix A is more detailed or restrictive than a similar requirement in the part 63 general
provisions or subpart UUUUU, or vice versa, the EPA must explain the need for the more restrictive
requirement.

Response to Comment 3: The EPA indicated in the preamble to the proposed rule that its intent was to
adopt the CAMR-based requirements for Hg monitoring because many sources had already installed
monitors to meet those requirements. Thus, the intent of our proposal was to use these specific
requirements in place of the general part 63 Hg monitoring requirements. These requirements for Hg
CEMS went through notice and comment rulemaking for the same set of sources. Although CAMR was
set aside on other grounds, these technical specifications and QA requirements reflect significant input
from stakeholders and analysis by the EPA to establish an appropriate foundation for Hg monitoring at
electric utilities under the CAA. For the final rule, we have made conforming changes to ensure that this
intent is carried out effectively throughout the rule text and Appendix A, as well as including certain
additional clarifications based on the input received in response to this proposed rule.

Comment 4: Commenters 17620 and 17691 state that it is unclear, from the form of the Hg emissions
limit and the compliance methodology, whether the EPA intends that the Hg limitations include total Hg
or only vapor-phase Hg. The commenters state that according to the proposal, continuous compliance
can be demonstrated by the use of Hg CEMS, which measure only vapor-phase Hg and that the EPA
also mentions of the use of Method 29 or Method 30B for demonstrating compliance. The commenters
state that Method 29 measures total Hg whereas Method 3OB measures only vapor-phase Hg.
Additionally, the commenters state that in its discussion of allowable certification methods for Hg
CEMS, the EPA references the use of the Ontario Hydro Method or EPA Method 29, each of which
measures total Hg.

Comment 5: Several commenters (17804, 17843, 18039) state that it is not appropriate to allow
compliance demonstrations without accounting for particulate bound Hg which can be a substantial
fraction of total Hg emissions. The commenters have determined that the filterable portion of total
particulate emissions for coal-fired EGUs without wet scrubber controls can produce an average of 30
percent- 40 percent filterable PM. The commenters recommend that the EPA require total Hg emissions
to be the basis of compliance demonstrations by taking into account the average particulate bound Hg
measured during the most recent stack test on that unit in combination with the total vapor-phase Hg
measured by the CEMS until such time as Hg CEMS to measure particulate-bound Hg are installed at a
unit. Commenter 17853 provides as an example the Massachusetts Department of Environmental
Protection's final Hg emissions regulation at 310 CMR 7.29(5)(a)3.g.ii.

Response to Comments 4-5: The Hg emissions limits were established based principally on the results
from Method 30B emissions tests (vapor phase Hg) coupled with data from some Method 29 test
programs. Though the Method 29 results would include the particulate fraction, this generally
constitutes less than 5 percent of the total Hg. The final rule then requires continuous monitoring for
units firing fuels other than liquid oil using either a Hg CEMS or a sorbent trap monitoring system both
of which measure vapor phase Hg concentration. The final rule allows for the use of Method 29, the
Ontario Hydro Method, or Method 30B if the source elects to use such methods when emissions testing
a liquid oil-fired unit. Method 29, Method 30B, or Ontario Hydro Method testing for Hg is not
applicable for other types of affected units.

105


-------
Comment 6: Commenters 17718 and 17781 request clarification with respect to section 63.10005(e).
The commenters state that under this section there is no mention of beginning to use data obtained
during the first 30-day operating period "after the monitoring system is certified," though this language
does appear in similar monitoring system sections (i.e., 40 CFR 63.10005(d)(4)-(6)). The commenters
note that there are sorbent trap monitoring system certification requirements (e.g., RATA) mentioned in
the proposed "Appendix A to subpart UUUUU - Hg Monitoring Provisions." The commenters question
whether it was the EPA's intent that data should not be used until the initial certification is completed.
Commenters also state that the EPA should clarify whether if sorbent trap monitoring systems are
certified prior to the compliance date the "30-day operating period" for determining initial compliance
begins on the compliance date. Commenter 17781 believes that any 30-day period within the first 180
days following the applicable compliance date should be allowed for the initial compliance
demonstration.

Response to Comment 6: This concern has been addressed by clarifying the language in the final rule.

2. Technical review of appendix A and incorporation of part 75 provisions.

Comment 7: Several commenters (17752, 17775, 18014) find similarities between Hg CEMS
requirements in Appendix A and the now-vacated CAMR provisions of Part 75. The commenters
generally support attempts to provide consistency between the proposal and Part 75, but Commenter
17775 does not believe all of the Part 75 requirements are necessary in a MACT standard or that the
proposal established that all requirements can be consistently met. Commenter 17775 incorporates a
memorandum by McRanie Consulting with the following technical recommendations for proposed
Appendix A:

1.	The consultant recommends adding language that specifically allows for use of backup monitors.
Commenters 17752 and 18014 also support such a clarification and commenter 17775 states that
such language should apply to both Hg CEMS and sorbent trap systems. Several commenters
(17752, 17775, 18014) also recommend incorporation of provisions for use of like-kind replacement
components and backup instruments as provided in sections 75.10(e) and 75.20(d). Commenter
17775 believes these provisions are necessary to minimize data loss during periods when an
instrument must be returned to the factor for repair. The consultant believes that a 720-hour like-kind
replacement provision is essential to maintaining acceptable Hg CEMS availability.

2.	The consultant and commenters 17752 and 17775 also recommend that more widespread use of
grace periods should be in the final rule; commenter 17752 believes that a 720-day grace period for
like-kind replacements should be sufficient for required factory repairs and that a grace period of at
least 24 hours is needed for weekly system integrity checks. Commenter 17775 believes that the
system integrity test is likely to be one of the most challenging tests because EGUs subject to the test
under state programs have reported frequent failures and the need for manual performance so that a
technician can observe the process and identify problems during the test. According to commenter
17775, these issues led Northeast States for Coordinated Air Use Management, (NESCAUM) to
conclude:

At this point, it appears that the equipment associated with the system integrity tests may
not yet be at the point where the test can be performed in an automated fashion with high
reliability. This affects how the tests can be scheduled because a technician needs to be
available to monitor them.

106


-------
Commenter 17775 states that if the system integrity test cannot be automated, EGUs will need to
monitor operating hours to determine when a test will be due, and ensure that a qualified technician is
available because most EGUs do not have technicians available to perform routine tests on nights and
weekends. According to the commenter, even if the test is scheduled to be performed on time, issues
with monitoring system breakdowns and the time necessary to complete maintenance could also result in
late tests. Commenter 17775 states that the proposal provides no basis for specifically excluding the test
from grace period provisions, and the commenter requests at a minimum that the final rule include an
operating hour grace period of at least 72 unit operating hours before data are invalidated because that
would provide an EGU time to schedule and perform a test if one were triggered unexpectedly by a unit
startup or shutdown, and such a grace period would be consistent with provisions for linearity checks, 3-
level system integrity checks, and RATAs. Commenter 17775 suggests that another possible approach
would be a calendar day interval for testing combined with an operating hour grace period to provide
relief if the unit is not operating or the monitoring system is out of service when the test is due.
According to the commenter, if the EPA does not provide some sort of flexibility, the availability of
valid Hg CEMS data for compliance calculations may be needlessly limited simply due to late tests that
do not indicate any actual problem with the monitoring system or data quality.

1.	The consultant recommends removing the second sentence of section 3.1.7 because the
recommended nominal span ratio yields a span that, according to the consultant, "makes it
impossible to comply with many of the other QA/QC requirements of this appendix because the
available NIST traceable Hg calibration gas concentrations are not compatible." The consultant also
points out that the second sentence of section 3.1.7 is inconsistent with section 3.2.1.4.2, and
commenter 17775 emphasizes how important these sections are for specifying appropriate rounding
procedures for establishment of span because of the current unavailability of NIST traceable Hg
calibration gases at lower spans. Commenter 17775 requests that the final rule include such rounding
provisions

2.	The consultant recommends removal of the "level detectable" and "detectable limit" terms in
sections 3.1.8 and 3.2.1.2.2.1 because "detection limit" is not defined and the meaning of the rule
language is unclear.

3.	The consultant and several commenters (17752, 17775, 18014) request that the final rule incorporate
cross-references to Part 75 for measurements required under Appendix A that are already required
under Part 75. Commenter 17775 believes that cross references are preferable to paraphrasing of the
Part 75 requirements in the final EGU MACT rule. The consultant presents an example, in proposed
Appendix A section 3.2.3.3, where the text specifies span requirements for CO2 and O2 monitors
using terms and concepts that are used under Part 75, but that are not used or defined elsewhere in
Appendix A. Commenter 17775 refers to the consultants review states that since these provisions are
incomplete and potentially inconsistent with Part 75 provisions, operators that already are complying
with Part 75 should have the option of simply meeting the Part 75 requirements. The consultant also
states that references to MPC should be removed from Appendix A because "MPC has no meaning
for O2, CO2, or stack flow rate in this proposed rule because there is no data substitution."

4.	The last sentence in section 4.1.1.3 should refer to Table A-l.

5.	The consultant believes that the value of "0.03 |ig/dscm" in section 4.1.1.5 should be

"0.02 |ig/dscm" to be consistent with both PS-12A and Method 30B, and the consultant recommends
adding a statement in section 4.1.1.5 invoking the acceptance criteria of PS-12A and Method 30B.

6.	The consultant recommends revising section 4.1.1.5.1 to adopt Part 60 and Part 75 language that
says more than nine runs can be performed but a maximum of 3 can be discarded.

7.	The consultant recommends removal of references to PS-6 because he is concerned that references to
PS-6 in Section 4.1.1.5.2 will lead operators and testing companies to the misconception that all of

107


-------
PS-2 applies to Appendix A procedures. The consultant further recommends that the final rule
include the relative accuracy calculations in Appendix A.

8.	The consultant believes there are problems units of measure and dry and wet bases within section 12
of PS-2 with respect to proposed Appendix A that are likely to create confusion and recommends
adding the following sentence to section 4.1.1.5.2, "For purposes of calculating the relative
accuracy, ensure that the reference method and monitor data are on a consistent basis, either wet or
dry." The consultant states that these comments are also relevant to section 4.1.2.3.

9.	The consultant relays recent exchanges between the agency's testing personnel and source testers
conducting Method 30B and PS-12B at units with very low Hg concentrations. According to the
consultant, the "breakthrough" specification is not achievable as Hg concentrations approach zero.
Commenter 17775 states that for concentrations < 0.5[j,g/m3but >0.1 |ig/m3, the alternative
breakthrough criteria could be < 50 percent of the section 1 Hg mass. For concentrations < 0.1 (^g/m3,
there would be no breakthrough criteria and the validity of the samples would rest on all other
performance specifications being met. A consistent achievable alternative specification also should
be provided in Method 30B. Commenter 17775 requests promulgation of revisions concurrent with
finalization of subpart UUUUU, or complete a rulemaking to revise PS-12B and Method 30B well in
advance of the subpart UUUUU compliance deadline.

10.	The consultant encourages the agency to expedite publication of the "codes" referenced in proposed
Appendix A for various parameters to facilitate development of reporting software by venders.

11.	The consultant believes that references to "...tests described in paragraphs 7.1.10.3 through 7.1.10.6
..." should be corrected to "...tests described in paragraphs 7.1.10.1 through 7.1.10.6 ..." but
generally finds section 7.1.10 to be confusing.

12.	The consultant states that section 7.2.5.3.3 requires electronic reporting of "The information in
paragraphs 7.1.2 through 7.1.19 ...." but advises that there are no sections 7.1.11 through 7.1.19.

Several commenters (17752, 17775, 18014) state that the EPA should consider adding provisions for
conditional data validation in the final rule similar to section 75.20(b)(3)(ii)-(vi); Commenters 17752
and 17775 also state that setting data as conditionally valid following the calibration error test (or other
maintenance activities that require further QA procedures) is a good provision for improving data
availability.

Response to Comment 7: The EPA acknowledges commenters' general support for finding consistency
with Part 75. For the items concerning backup monitoring and conditional data validation, the EPA
agrees and has made changes to the final rule and Appendix A to provide for backup monitoring and
conditional data validation similar to part 75 approaches. For the concerns raised with the system
integrity check requirement, the final rule retains the weekly system integrity check requirement,
without a grace period. However, to add flexibility, the required frequency of the test has been changed
from once every 168 operating hours to once every 7 operating days. Operating days are much easier to
track than operating hours. The test can be done at any time during the 7th operating day, rather than
requiring it to be done at a certain hour. We believe that this added flexibility will allow utilities to
schedule the test in accordance with the technician's work schedule.

For item 1, the EPA has added a cross reference in section 3.1.7 to section 3.2.1.4.2 with respect to
rounding in order to provide for consistent implementation. For item 2, the EPA notes that the use of
zero gases for calibration is a well-understood concept within the industry. The rule language has been
revised slightly to provide for a workable standard that can adjust over time as industry-standard
detection limits may change. For Item 3, the EPA agrees, and has made a number of changes to provide
direct references to Part 75 in Appendix A in lieu of specifying comparable provisions in this rule. For
the specific recommendations in items 4 through 12 above, the EPA has made conforming revisions

108


-------
generally consistent with these clarifying suggestions. In particular, the absolute value relative deviation
specification for paired Method 29 or Ontario Hydro method sampling in section 4.1.1.5 has been
changed to 0.2 |ig/dscm to be consistent with Method 30B. Section 4.1.1.5.2 has been revised to ensure
that RATA data are compared on a consistent moisture basis. Regarding the recommendation for an
alternative "breakthrough" specification for Method 30B and PS-12B, the EPA plans to propose, in
revisions to Method 30B, the alternative breakthrough specifications suggested by the commenter to be
applicable to relative accuracy testing. The EPA does not plan to modify the breakthrough specifications
for compliance testing applications of Method 30B as it is important to maintain tight specifications
even at low levels; testers will need to use longer sampling times or more low background sorbents if the
breakthrough criteria cannot be met. We have also modified section 4.1.2.2 of Appendix A to include
the alternative breakthrough specifications suggested by the commenter for relative accuracy testing of
sorbent trap monitoring systems; the agency will consider revising PS-12 B at a later time as part of
ongoing evaluation of that performance specification. The EPA will be proceeding with ECMPS
modifications with appropriate reporting codes as the commenter notes is needed.

Comment 8: Commenter 18449 states that many of the assumptions and regulations regarding "Span"
date back a generation or more when chart recorders and 4-20 mA links were commonly used.

According to the commenter, in those days, readings exceeding the "Span" value resulted in invalid
data, and the chart recorder or the 20 mA loop pegged, clamping the data at the maximum span value.
The commenter notes that much has changed with both instrumentation and data acquisition systems.
According to the commenter:

1.	All of the commercially successful Hg CEMS are atomic fluorescence (AF) based and are linear
over a very wide range, (e.g., Tekran: 0.01 - 300 (J,g/m3)

2.	The systems operate linearly over this range as one span range, (i.e., There are no range knobs, or
other adjustments required to obtain this range.)

3.	They report digitally, such that the actual concentration value is reported. There is thus no loss of
accuracy in transmitting this wide range of values.

4.	The systems report with an "overload" flag when they finally reach their limits, positively
identifying periods of invalid data.

5.	Provided that a CEMS can demonstrate good (i.e., low) zero readings, using a higher concentration
gas to calibrate a Hg CEMS does not affect its low concentration accuracy. For example, states the
commenter, calibrating an AF based CEMS using a 9 |ig/m3 calibration gas will not cause it to read
a subsequent stack concentration value of, say 1 [j,g/m3 any less accurately than having calibrated it
with a 4.5 [j,g/m3 calibration gas; in fact, the 9 jag calibration gas would probably yield a more
accurate number since the uncertainty of the actual cal gas concentration is smaller at higher
concentrations. (According to the commenter, this is largely a function of the uncertainty that NIST
can provide.)

Commenter 18449 states that, despite the past practice, any requirement to run dual spans is totally
unnecessary for Hg CEMS. The commenter notes:

1.	Each span range requires independent QA/QC. This requires three separate concentrations of
elemental and ionic calibration gases for each span. This would double the QA/QC time required,
resulting in more periods of missing data.

2.	All CEMS use gas generators rather than bottled gases, but these generators operate over a limited
range limitations. An elemental generator that is designed to produce sub-microgram levels may be
different than one that produces say 100 ug/m3 for the occasional high peak.

109


-------
3. Many systems have separate ionic calibrators. If two ionic calibrators are required, the total could
become four separate calibrators per system, which is impractical.

The commenter believes the EPA should take this opportunity to finally address this issue in a rational
manner. According to the commenter, calibration of Hg CEMS should be at the normal (low level) span
range to maximize accuracy. Manufacturers should be allowed to demonstrate the dynamic range of
their instrumentation. The commenter states that if an instrument calibrated at a normal span range was
shown to be capable of measuring a much higher concentration accurately, (within x percent) the data
would be deemed valid no matter how much it exceeded the span value. According to the commenter,
this might take specialized generators capable of producing high output concentrations, and a factory
"type approval" or one time on-site demonstration would be sufficient.

Response to Comment 8: The EPA agrees that dual range Hg CEMS are not a requirement of this rule.
Appendix A of this rule provides guidance and requirements for establishing the span value and full-
scale range for monitoring with a Hg CEMS. The span value is established based on the Hg
concentration corresponding to the applicable emission limit. Establishing the range will require
identifying the Maximum Potential Concentration (MPC) which defines the full-scale range that the Hg
CEMS being used must be capable of monitoring.

Comment 9: Commenter 17800 states that it is unrealistic to require submittal of hourly Hg data in a
format that this similar to part 75 (see Appendix A section 7.2). The commenter notes that in the Cement
MACT the EPA has not required the submittal of hourly data for any of the CAA section 112 listed
pollutants. According to the commenter, the reporting requirements in these rules rely solely on the
recordkeeping and reporting requirements contained in 40 CFR part 63, subpart A and 40 CFR part 60,
subpart A. The commenter states that in the proposed Utility MACT rule, compliance with the Hg limit
is determined on a 30-day rolling average and thus the need for hourly measured Hg concentrations is
superfluous and the EPA has provided no reason for this treatment. The commenter recommends the
EPA revise Appendix A to subpart UUUUU and require only semi-annual reporting of what is required
in 40 CFR part 63, Subpart A.

Response to Comment 9: The EPA has retained the hourly reporting of CEMS data, using the ECMPS
approach as outlined in the proposed rule. This approach was supported by a number of commenters.
See further discussion of this decision under responses to comments in 5B03 of this document.

Comment 10: Commenter 17800 states that the EPA's assumption that there would be little or no cost
for flow, C02 or 02, and moisture monitors is invalid (see 86 FR 25033). The commenter notes that its
part 75 monitors do not have moisture monitors and adding them will be an added expense.

Response to Comment 10: Moisture monitoring is not required but is an option for use in calculating
emissions in units of the emission limit. The EPA expects that units that currently have moisture
monitors installed under part 75 may use those under this rule, but that other sources will use one of the
other options available, such as a moisture default value.

Comment 11: Commenter 17877 states that weekly system integrity checks should be eliminated and
are unnecessary to demonstrate compliance with a not-to-exceed limit. According to the commenter, the
existing CAMR performance criteria were created under the auspices of a cap and trade program. The
commenter states that performing the standard ongoing QA tests that are deemed sufficient for the Acid
Rain Program (daily calibrations, quarterly linearity checks, and annual RATAs) would be appropriate
and simplify ongoing QA tests to a consistent set of requirements. Further, according to the commenter,

110


-------
system integrity checks introduce a safety hazard due to the use of chlorine and historically have been
very difficult to pass with the current maturity level of the monitoring technology. The commenter states
that at a minimum, a qualified technician would have to be devoted to a full day each week in order to
try and complete a successful integrity check and that many more man-hours are already going to have
to be devoted to maintain CEMS for utilities that will also be operating PM and HCL monitors. The
commenter suggests that as an alternative to a weekly integrity check, a quarterly sorbent trap test (in
non-RATA quarters) along with the quarterly linearity check.

Response to Comment 11: The EPA disagrees and has retained the proposed requirement for weekly
system integrity tests if the CEMS uses a converter and if daily calibrations are not done with a NIST-
traceable source of oxidized Hg. The system integrity test assesses the efficiency with which the
converter reduces oxidized Hg to elemental Hg; conversion efficiency must be confirmed as poor
efficiency would result in a low bias in the Hg measurements. The EPA also disagrees with the labor
hour assumptions for this test. At least one vendor has developed an automated solution to the weekly
system integrity checks. In addition, to add flexibility, the required frequency of the test has been
changed from once every 168 operating hours to once every 7 operating days. Operating days are much
easier to track than operating hours. The test can be done at any time during the 7th operating day, rather
than requiring it to be done at a certain hour. We believe that this added flexibility will allow utilities to
schedule the test in accordance with the technician's work schedule.

3. Achievability of Hg performance specifications.

Comment 12: Commenter 18023 states that Hg CEMS are not capable of achieving the data availability
of CEMS for other pollutants because Hg presents unique problems. According to the commenter, first,
Hg levels are being measured equivalently in parts per trillion (ppt) whereas other pollutants are
measured on a parts per million (ppm) basis, Hg has a tendency to adsorb and desorb from the sampling
system, and the measurement technology requires considerable time to stabilize following maintenance.
According to the commenter, during that period of stabilization, significant drift (false trending of data)
can occur making accurate reporting of data nearly impossible. The commenter states that currently,
Appendix A of the proposed rule contains only the requirement that entities report when data is
unavailable And Appropriately, the rule does not set a percentage of time for how often data is required
to be available. According to the commenter, utilities do not have sufficient experience in operating Hg
CEMS, and with all of the QA requirements expected, it is difficult to estimate what an appropriate
availability limit would be. Commenter 18023 suggests that therefore the EPA should allow utilities to
gain several years of experience with these systems and the requirements of the final rule and then
revisit the availability question through a notice and comment rulemaking after a request for information
from the industry.

Comment 13: Commenter 17775 recollects previous court challenges to Hg CEMS requirements under
CAMR in UARG v. EPA, No. 06-1394 (D.C. Cir. 2006) regarding the viability of Hg CEMS technology.
Commenters (17775, 17728) state that data availability is a concern based on a report in the docket
(EPA-HQ-OAR-2009-0234-14040) entitled "Technologies for Control and Measurement of Mercury
Emissions from Coal-Fired Power Plants in the United States: A 2010 Status Report, Northeast States
for Coordinated Air Use Management, July 2010." According to the commenter, this report notes the
existence of reasonable concerns about the reliability of Hg CEMS and that, in general, availability is a
concern for new technology. The commenters state that the proposal did not provide data to establish
consistent achievability of all proposed specifications for Hg CEMS.

Ill


-------
Response to Comments 12-13: The final rule does not specify a data availability requirement;
however, the rule does specify that CEMS must be operated at all times that the affected unit is in
operation (except for CEMS malfunctions and QA checks). The agency believes that the record
indicates adequate availability of Hg CEMS necessary to comply with the final standards. To the extent
that a facility does not believe the CEMS can function to provide adequate data availability at a
particular source, the facility may elect to use a sorbent trap monitoring system and/or a backup
monitoring system.

Comment 14: Commenters 17677 and 17681 relay experience measuring Hg emissions since 2008
using a dilution-extractive CEMS and state that the proposed Hg limit is below accurately measureable
concentrations. Through RATA one commenter asserts significantly increased error as the Hg emission
levels decline to less that 3 ug/m3. The commenter states that as allowed in the Hg CEMS RATA
regulations, emissions less than 5 ug/m3 are allowed an alternate allowance from relative accuracy and
given a plus or minus 1.0 ug/m3 difference from the EPA method 30B sorbent trap reference method
result and that the proposed rule sets the Hg limit well below the accuracy capabilities of Hg CEMS.
The commenter contends that the proposed limit is fundamentally immeasurable and states that the EPA
should set a Hg emission level that is measurable and supported by sound scientific data pertaining to
CEMS technology.

Comment 15: Several commenters (17638, 17681, 17930) state thatHg CEMS are not sufficiently
accurate or reliable at the EPA's proposed emission levels to justify their use. Commenter 17930 states
that the UV lamps in Hg CEMS are particularly troublesome and that problem, along with others, results
in numerous failures of the CEMS.

Comment 16: Commenter 17675 describes agreements with the state permitting authority to reduce Hg
emissions and the associated experience with Hg CEMS on coal-fired EGUs. According to the
commenter, these systems provide accurate and audited continuous monitoring for Hg emissions. Even
though these CEMS are currently state of the art, the lower limit of quantification for these CEMS and
other similar technology is very near the Hg level required to be achieved in stack gases by the proposed
Hg limits as documented in a recent study report by Dennis Laudal of the Energy & Environmental
Research Center at the University of North Dakota titled "DETERMINING THE VARIABILITY OF
CMMS AT LOW HG LEVELS". The commenter states that while it is likely that the quantification
limits of Hg CEMS will improve as more systems are installed to monitor for compliance with the
MACT standards, EGUs subject to these proposed standards that prefer to install CEMS early may be
forced to install sorbent traps to be assured that the systems will meet MACT monitoring
requirements. Commenter 17675 believes that sources that have already installed Hg CEMS should be
given an automatic extension of the Hg monitoring requirements if the CEMS that are already installed
need to be upgraded to meet the EPA's monitoring requirements.

Comment 17: Commenter 17728 relays experience with Hg CEMS operating on side-by-side sister
units and states that the instruments do not yield comparable results for unknown reasons.

Response to Comments 14-17: If for a particular source, a facility believes that a Hg CEMS cannot
achieve the performance requirements needed to satisfy the final standards, the facility may elect to
install and use a sorbent trap monitoring system to monitor for continuous compliance. There are data in
the draft report cited by one of the commenters, "DETERMINING THE VARIABILITY OF CMMS AT
LOW HG LEVELS," that demonstrates reasonable performance of at least one Hg CEMS at Hg levels
below 1.0 ug/m3 down to approximately 0.1 ug/m3.

112


-------
Comment 18: Commenter 17725 states that based on their experience with eight installed Hg CEMS at
three facilities in New York, the cost to operate and maintain these systems are not warranted given
obvious compliance. According to the commenter, in general, CMMS are expensive to operate and
maintain, there is a limited pool of qualified support contractors, they are tricky to install, difficult to
operate correctly, and, since the installation of baghouses at Dunkirk and Huntley, the concentrations are
so low that we are not always confident of the results even when the calibration and all requirements are
met. The commenter states that if the CMMS had been required under CAMR, the commenter suspects
that resolving the problems would have been very difficult. The commenter recommends a reduced
monitoring plan if facilities can demonstrate de minimis emissions.

Response to Comment 18: The LEE provisions in the final rule allow for reduced monitoring for many
facilities with very low emissions. The EPA believes those provisions allow for cost-effective
monitoring where sources have very low emissions.

Comment 19: Commenter 17761 states that based on their more than 4 years of experience with Hg
CEMS at the Scott Energy Center Unit 4 Hg CEMS can overstate actual emissions, demonstrates
significant variability, does not necessarily correlate with stack testing measurements (20-25% higher
than through stack testing), and will have difficulty meeting the aforementioned 95% availability
requirements.

Response to Comment 19: See response to Comments 12 and 13 above.

Comment 20: Commenter 17805 states that based on their experience with Hg CEMS they have found
the system to challenging and the company is still working with the Hg CEMS vendor to resolve
monitor issues. Based on this, the commenter states that it is still appropriate for the EPA to allow
alternative methods of demonstrating compliance. The commenter further notes that the EPA should
confirm with suppliers and vendors that all necessary Hg NIST traceable calibration gases are available.
The commenter also believes the certification requirement for the monitoring system NIST certified
calibrator by an offsite third party vendor will create challenges for systems already installed under
state-specific requirements. The commenter recommends the EPA work with state agencies to
coordinate these requirements.

Commenter 17805 agrees with the EPA that application of a bias adjustment for Hg emissions is not
necessary. It is the commenter's understanding that a bias adjustment, as used for S02 emissions in the
Acid Rain Program, was primarily intended to assist with ensuring emissions were adjusted properly for
cap and trade of emissions. Since Hg will not be traded, the commenter opines that bias adjustment is
not necessary.

Response to Comment 20: The EPA has developed the approaches to Hg CEMS calibration including
NIST traceability of elemental and oxidized Hg gas generators based on its work with NIST and
numerous other stakeholders. To the extent that the commenter or others believe an alternative
calibration approach can provide equivalent results, then the commenter may apply for an alternative
method under the provisions of section 63.7(f).

Comment 21: Commenter 17690 states that because New York State requires Hg CEMS they are in a
unique position to comment on the proposed rule's continuous compliance requirements. The
commenter believes that all of the proposed additional monitoring requirements are similar to the New
York requirements in that they represent the specification of an advanced technology that does not have
a long and widespread history. The commenter states that while the testing equipment vendors may

113


-------
argue that their monitoring systems are fully functional, the commenter's experience is that for these
types of applications the vendor infrastructure, industry capabilities, and even regulatory understanding
and support are inadequate to meet the compliance schedule in the proposed Utility MACT rule. Further
background information and detail to this comment are provided in Appendix 2 (see EPA-HQ-OAR-
2009-0234-17690-Al.pdf for Appendix 2 pg 21.) The commenter provides the following observations
and recommendations:

1.	Commenter agrees that it is appropriate to harmonize monitoring and reporting requirements, to the
extent possible, with those of 40 CFR Part 75.

2.	Commenter supports the option to simply integrate air toxic emissions data and QA test results into
the existing 40 CFR Part 75-compliant data acquisition and handling system computers already in
place. However, we would prefer to use the 40 CFR Part 60 deviation-based reporting approach
because acid gas, metal and PM hourly measurements have little value; ultimately, long-term totals
are of greater value in determining impact.

3.	According to the commenter, it is appropriate to use the existing Emissions Collection and
Monitoring Plan System (ECMPS) infrastructure for reporting air toxics data and QA test results but
commenter does not believe that is appropriate to develop a different reporting system.

4.	Commenter supports disabling the bias adjustment for all air toxics data because bias adjustment is
only appropriate for emissions trading programs.

5.	Commenter agrees that hours when a monitoring system is out of service should simply be counted
as hours of monitor down time, to be counted against the percent monitor availability.

6.	Commenter favors the EPA's proposed streamlined continuous compliance approach and suggests
that if this program were to integrate the Clean Air Markets Division (CAMD) staff experience to
the maximum extent possible that the reporting process will be user friendly and efficient.

7.	Commenter recommends adding at least 2 years to the final implementation date for the continuous
monitoring requirements. During the extended implementation period, affected sources should
provide documentation of procurement, installation and testing progress. The EPA and NIST should
develop the necessary traceability protocols and testing programs necessary to support widespread
air toxic continuous monitoring programs. It would also be appropriate to try to develop sorbent trap
methodologies for air toxics.

8.	Commenter recommends that if continuous monitoring at any affected source finds that the majority
of observations are less than a certain level then the source should have the option to discontinue
continuous emission monitoring and replace it with regular stack testing and compliance assurance
monitoring. For example, for Hg, that certain level should be 2 [j,g/m3.

Response to Comment 21: The EPA largely agrees with the comments related to the use of ECMPS
and electronic reporting of data. See further discussion under section 5B04 of this document. The EPA
disagrees with the need for an additional 2 years for compliance with the monitoring requirements.
Compliance with the final rule is 3 years following promulgation, which should provide sufficient time
for continued advancement of Hg CEMS monitoring technology, which has already been demonstrated
successfully at numerous facilities. For the bias adjustment comments, see response to Comments 40
and 41, below. Regarding data availability, see response to Comments 12, 13, and 19, above.

Comment 22: Commenter 18014 states that the proposal does not justify the burden of requiring
ECMPS reporting because the data reporting requirements in Appendix A for Hg go far beyond what is
necessary. According to the commenter, the EPA portrays this proposed reporting requirement as easy
and that sources would "simply integrate Hg emissions data and QA test results into the existing Part 75-
complianct DAHS." According to the commenter, the EPA creates a false dichotomy stating that it
considered two options:

114


-------
1.	For deviation and data assessment reports, sources would "need to have a data handling
system(DAHS) that: (1) Is programmed to capture data from the Hg CEMS; (2) uses the criteria in
Appendix F to Part 60 to validate or invalidate the Hg data; (3) calculates hourly averages for Hg
concentration and for the auxiliary parameters (e.g., flow rate, 02 or C02 concentration) that are
needed to convert Hg concentrations to the units of the emission standard; (4) calculates 30 boiler
operating day rolling average Hg emission rates; and (5) identifies any deviations that must be
reported to the agency."

2.	"Simply integrate Hg emissions data and QA test results into the existing Part 75-compliant DAHS"
and submit data through ECMPS. After presenting these two options, the EPA states that it obtained
"feedback from several DAHS vendors" who suggested the cost of the second option was "similar,
and some cases, less than the cost of the first option."

According to the commenter, however, any software under Option 2 would have to do everything the
EPA described under Option 1. The commenter asserts that sources would likely integrate the new
requirements within the DAHS that they currently use for Part 60 and Part 75 reporting but this does not
mean that the proposed reporting scheme would be simple or cheap to implement.

Response to Comment 22: The EPA disagrees. As other commenters have stated generally, the use of a
unified approach to CEMS reporting under this rule and the Part 75 reporting already conducted by the
affected EGU population provides a straightforward and consistent reporting method for the industry.

Commenter 17805 supports using a Hg CEMS to demonstrate continuous compliance and has been
operating and maintaining a Hg CEMS to report emissions at the Lewis & Clark Station to the Montana
Department of Environmental Quality for about 2 years. However, the system has been challenging and
the company is still working with the Hg CEMS vendor to resolve monitor issues, and therefore, it is
still appropriate for the EPA to allow alternative methods of demonstrating compliance.

Comment 23: Commenter 17626 states that Hg limits need to be set to be consistent with the
technology not only for control but for reliable and accurate measurement. The commenter believes that
the proposed levels may be theoretically achievable, but current monitoring technology and
standardization does [not] exist to measure these levels accurately and precisely. According to the
commenter, this places the supplier in the position of being unable to guarantee such performance. The
commenter notes it is not a not a measurement supplier but supports the position taken by such
organizations as the Institute of Clean Air Companies (ICAC) to resolve these issues.

Response to Comment 23: If for a particular source, a facility believes that a Hg CEMS cannot achieve
the performance requirements needed to satisfy the final standards, the facility may elect to install and
use a sorbent trap monitoring system technology to monitor for continuous compliance. See section
5A06 for further discussion of Hg CEMs and sorbent trap monitoring.

Comment 24: Commenter 17637 states that it is not precisely determined whether test methods exist
that are accurate, reliable and consistent enough to ensure compliance with the stated emission limits.
Hg stack testing and other on-line measurements have not been fully developed to provide an accurate,
repeatable and reliable level of Hg emissions. According to the commenter, although a performance
specification has been proposed by the EPA, the hardware to support such a standard in the day-in-and-
day-out environment is still unproven.

Response to Comment 24: The EPA disagrees that the test method and monitoring hardware are not
fully developed to meet the stated emission limits in the final rule. Performance Specification 12B which

115


-------
is required in the rule along with Performance Specification 12A which has similar hardware
requirements to those in the rule have both been promulgated since September 9, 2010 (75 FR 54970).
See 5A06 in this document for further discussion of Hg CEMS and sorbent trap monitoring.

4. QA requirements for elemental and HgCl2 generators.

Comment 25: Commenter 17197 has concerns with Appendix A, section 3.2.1.2 Reagent and Standards
Requirements and sections 3.1.4 and 3.1.5 based on experience with an Hg CEMS since 2007. The
commenter has concerns with the referenced NIST traceability protocol's 8-quarter recertification
interval for HgCh "user generators" because these interim protocols will require the "user generators" to
be removed from the Hg CEMS and sent to the manufacturer for recertification. According to the
commenter, these calibration gas generators are integral components of the TEKRAN Hg CEMS and are
not easily removed or reassembled. The commenter states that the TEKRAN Hg CEMS is not designed
to accept calibration gas from a generic "Field Reference Generator," or cylinder gas standard (NIST
transfer standards) and that recertification of the "user generators" may require that many of their
subassemblies (gas and liquid flow meters, temperature controllers) be calibrated to NIST reference
methods. According to the commenter, this requires specialized equipment and knowledge generally
available only from the manufacturer and consequently, the "send-to-manufacturer-for-recertification"
prerequisite is the only real option provided under the interim protocols. According to the commenter,
this option presents significant challenges, costs, and risks because the sequence of removing the user
generator, installing the temporary user generator, configuring the DAHS for the temporary user
generators, and then reinstalling the recertified user generator and reconfiguring the DAHS for the
recertified user generators is very complex. The commenter states that specialized TEKRAN knowledge
is required for these certification activities. A significant concern for the commenter is the potential for
generator and Hg analyzer contamination, and equipment damage during disassembly, shipping, and
reassembly. According to the commenter, the elemental and HgCh generators contain very delicate
subassemblies that can be damaged in shipping, which may affect the recertification. The commenter
states that to help ensure proper Hg CEMS operation, onsite equipment vendor technical assistance
would likely be required to install the temporary user generators and to reinstall the recertified user
generators. The commenter believes that the significant costs, technical challenges, and equipment risks
associated with the interim NIST traceability protocol's user generator recertification interval provisions
are overly restrictive. Consequently, the commenter advocates that the proposed NIST traceability
specifications referenced in Appendix A only become effective when they become final and that the "...
or an interim version of that protocol' phrase in Appendix A, sections 3.1.4 and 3.1.5 definitions be
deleted.

Comment 26: Commenter 17197 also recommends that the interim NIST traceability protocols be
modified to include a recertification interval extension option for the user generators when the Hg
CEMS meet a RATA incentive specification. The commenter proposes that the final NIST traceability
protocols contain a RATA performance incentive option that extends the user generators' 8-quarter
recertification interval another four quarters if the Hg CEMS successfully passes the annual RATA
testing at the following proposed incentive specification:

•	10 percent RA,

•	or < 0.8 [j,g/scm difference, if RM average is < 5.0 jag /scm.

According to the commenter, the proposed <0.8 [j,g/scm difference is consistent with the linearity and
integrity check requirements. It is the commenter's view that the user generators should retain their
NIST certification as long as the Hg CEMS is able to achieve the alternate RATA incentive performance

116


-------
specification and other periodic QA/QC requirements (i.e., daily calibration, weekly integrity, quarterly
linearity). The commenter asserts that if the Hg CEMS cannot achieve the RATA incentive
specification, the owner/operator should have a 60-day grace period to recertify the user generators. The
commenter supports a 60-day grace period due the complexity of the user generator recertification
process.

Response to Comments 25 and 26: The EPA disagrees. The interim NIST traceability protocols for
elemental and oxidized Hg gas generators represent significant effort on the part of the EPA, the CEMS
vendor community, and affected sources to examine the calibration generator traceability issues, and
devise an agreed upon approach for addressing those issues. In fact, one part of this collaborative effort
between the EPA and its stakeholders focused on the development of an approach to allow the elemental
Hg generators to remain 'in the field' for recertification and one of the organizations representing
industry demonstrated how it could be effectively accomplished.

5. Monitoring challenges for new unit Hg limits.

Comment 27: Commenter 17622 believes that Hg CEMS are superior to sorbent traps because
continuous monitoring is best done with methods that provide "real time" monitoring that can alert
operators to changes in conditions that affect emission rates. According to the commenter, sorbent traps,
while a valid continuous measurement method for Hg emissions, do not provide adequate response time
to be useful for control and achievement of compliance at the new unit limits. The commenter believes
that operators will likely target lower emissions levels (e.g., -50 percent of the limit for a new unit) for
their control set points, in order to have sufficient margin to achieve the proposed 30-day rolling average
limitation. According to the commenter, as electronic real-time Hg CEMS will likely be used for
emissions control, monitoring and reporting, there are a number of prospective hurdles for new units
because commercially-available Hg CEMS have not been fully certified at low levels (<1.0 (J,g/m3) due
to the NIST standard at 0.5 [j,g/m3 only recently being available. Commenter 17622 goes on to state that
the EPA NIST protocol for traceability of Hg generators has not been implemented at Hg concentrations
<0.5 [j,g/m3. According to the commenter, more testing, and possibly development and evaluation of
commercially-available Hg generators, is needed to ensure that NIST traceability can be demonstrated
and that the Hg CEMS enable control methods for units to stay in compliance. The commenter is
concerned that the low Hg emissions level required for new units may be lower than the uncertainty of
available measurement methods. The commenter states that Sorbent Trap Reference Method 3OB
requires a fresh look, particularly relative to sampling protocol and lower limits of detection (LLD) to
meet and certify the new EGU limits for Hg and that it is unlikely that current electronic Hg CEMS can
be confidently or reliably employed for monitoring, control and reporting of prospective new EGUs
emissions under the proposed Utility MACT. According to the commenter, there are clearly both
challenges and concerns about the traceability of commercially - available Hg CEMS required to
effectively administer the proposed existing unit emission limits. The commenter recommends that the
EPA develop a strategic initiative with NIST, targeting lower-level Hg (i.e., <0.5 (J,g/m3) calibration and
standards traceability and support for Hg CEMS and sorbent trap methods.

Comment 28: Commenter 17758 states that the proposed new source Hg limit cannot be measured by
any current or planned instrument, and even if a new unit could meet the limit, there is no way to assess
compliance.

Response to Comments 27 and 28: The final rule provides the option for use of either Hg CEMS or
sorbent trap monitoring systems. The EPA believes the record clearly shows these to be proven
technologies, each providing certain advantages. For existing and some of the new unit limit standards,

117


-------
the level of the NIST traceable Hg standard is adequate and consistent with existing applications of Hg
CEMS. For the lowest new unit standard, the affected facilities may opt to use sorbent trap monitoring
systems to comply. As noted in a previous response, there are data in the recent draft report entitled
"DETERMINING THE VARIABILITY OF CMMS AT LOW HG LEVELS," that demonstrate
reasonable performance of at least one Hg CEMS at Hg levels below 1.0 ug/m3 down to approximately
0.1 ug/m3.

Comment 29: Commenter 17704 supports both the use of Hg CEMS and the alternative use of sorbent
traps as proposed. The commenter also supports the proposed use of 30 days worth of valid Hg CEMS
data as the initial compliance test.

Response to Comment 29: The EPA acknowledges this support. See further discussion of sorbent trap
monitoring option, below.

Comment 30: Several commenters (17758, 17868, 18428) state that the Hg monitoring requirements
should be revised because the accuracy of Hg CEMS near the concentration of the proposed existing
source limit is questionable, and one commenter states the technology is not viable at the proposed level
of the new source limit for the following reasons:

•	The high relative uncertainty of NIST-traceable calibration gases and the lack of any NIST-
traceable calibration gases corresponding to the proposed emissions standard.

•	Persistent issues transporting samples from the stack to the measurement cell.

•	The EPA acknowledged unreliability of Hg CEMS at concentrations corresponding to the
standard when responding to questions on the EGU ICR; see
https://utilitvmacticr.rti.Org/FAO/FAQEmissionsTesting.aspx#TEST-002.

Commenter 17758 states that without further investment in developing Hg CEMS technology to address
issues with the availability of NIST-traceable calibration gases at the appropriate concentration levels
and sample transport, the only viable option for electric utilities for meeting the continuous Hg
measurement requirement is to install, certify and operate a Hg sorbent trap-based monitoring system
meeting the specifications in PS12B.

Response to Comment 30: See response to Comments 27 and 28 above.

Comment 31: Commenter 17383 states that they installed CEMS in preparation for the implementation
of CAMR and discovered that these monitors took significant man-hours to maintain and to insure their
accuracy. According to the commenter, the EPA has left the long-term operational problems, including
the development of adequate calibrators and calibration gases to industry. The commenter states that
with respect to standards for new units, the EPA developed standards for which there are not accurate
and reliable monitoring methodologies for demonstrating compliance.

Response to Comment 31: The final rule allows for sources to use Hg CEMS or sorbent monitoring
traps at the choice of the source operator. Sorbent trap monitoring has been shown to be highly reliable
and accurate for long term monitoring of HG emissions. Those options should provide sources with the
flexibility to select and operate the monitoring system that provides effective data collection sufficient to
demonstrate compliance. We understand the concern about the technical hurdles with applying new
technologies but we disagree that the Hg CEMS technology is not ready for this application. See also the
response to Comments 14-17, above and 32-34, below.

118


-------
6. Sorbent traps.

Comment 32: Commenter 17402 expresses strong support for the use of sorbent traps as the preferred
method for Hg monitoring because the commenter's experience has been that CEMS struggle to
measure low levels of Hg in the range of 0.10 |ig/m3 to 0.50 |ig/m3. By contrast, according to the
commenter, sorbent traps are demonstrably capable of measuring Hg in that range, and sorbent traps
offer a more consistent and accurate means for monitoring compliance. The commenter states that
consequently, the EPA should ensure that sorbent traps remain a permissible means of compliance
monitoring in the final rule. If the EPA decides to allow only one method of monitoring, the commenter
favors the use of sorbent traps because of their heightened accuracy when compared with Hg CEMS.
The commenter relays specific experience with both CEMS and sorbent traps that indicates monitoring
results with sorbent traps are more reliable. The commenter believes that it would be far more reliable to
look to sorbent traps for compliance with the MACT rule for facilities emitting more than 22 pounds per
year, and the commenter provides a lengthy list of problems encountered with Hg CEMS deployments
and highlights how sorbent traps do not encounter these problems.

Comment 33: Commenter 18023 states that a sorbent trap-based Hg monitoring system is not a realistic
option for units using ACI because real-time feedback from the CEMS is needed to adjust the ACI rate,
but a sorbent based monitor does not provide real-time feedback. According to the commenter, a
dilemma for new units is that it is quite possible that the only mechanism to detect the new source limit
will be through sorbent trap systems, but the new source Hg emission limit is so stringent that it will
require sorbent injection for control, yet sorbent trap based monitors cannot be used to modulate ACI
systems. The commenter states that sorbent trap based Hg monitoring systems would have limited use
on any unit unless the compliance averaging time is extended to at least a 90-day block average because
if significant amounts of data are lost over the 30-day compliance period, then demonstrating
compliance becomes problematic. According to the commenter, sorbent trap based Hg monitoring
systems have the potential for losing at least seven days' and as much as fourteen days' worth of data.
The commenter states that the potential loss of data out of a 30-day period would be a particular problem
for units that must meet the new source limit because the Hg compliance limit is so low for those units.

Comment 34: Commenters 17808 and 18025 support the use of sorbent traps and note that the EPA
should not assume that most EGUS have Hg CEMS.

Comment 35: Commenter 18421 strongly supports the EPA's proposal to require the use of CEMS or
sorbent traps for Hg as this will ensure affected sources can demonstrate continuous compliance with the
proposed Hg emissions standards. According to the commenter, the EPA's assessment that most, if not
all, units that would have been subject to the CAMR had purchased an advanced Hg monitoring system
like CEMS or sorbent traps is supported by evidence in a report by NESCAUM. The commenter states
that according to NESCAUM, Hg CEMS and sorbent traps are currently in use on over 700 coal-fired
power plant stacks (over 600 Hg CEMS and nearly 100 sorbent traps) (see NESCAUM, Technologies
for Control and Measurement of Mercury Emissions from Coal-Fired Power Plants in the United States:
A 2010 Status Report). According to the commenter, the EPA also correctly points out that many states
require coal-fired units to install and operate such controls to demonstrate compliance with SIP or
consent decrees.

Comment 36: Commenter supports the inclusion of sorbent trap monitoring systems as an appropriate
testing method for continuous Hg monitoring. Commenter installed both CEMS and a sorbent trap on
Unit 2 at its Spurlock Station in 2008 to compare the operation and maintenance characteristics of the
two technologies; operation of the Hg CEMS began in October 2008 and sorbent trap monitoring in

119


-------
January 2009. The commenter states that it has experienced recurring reliability issues with the Hg
CEMS including constant calibration drift issues, sample transport issues, probe convertor failures, Hg
analyzer and Hg lamp failures, design issues that result in a time consuming process to diagnose
problems, the need for continual recertification of the calibrator and unreliable operation due to
mechanical breakdowns. The commenter's experience with a Hg sorbent trap monitoring system has
been positive due to a number of strengths in the system including reliable design with no sample
transport issues (the sample is collected at the end of the probe in the traps), the system is simple,
problems are diagnosed easily and quickly, the system is appropriate for wet stacks and the system
provides accurate Hg data.

Response to Comments 32-36: The final rule includes the option of using sorbent trap technology as
well as Hg CEMS for monitoring compliance with the Hg standard. For the ACI control rate issue raised
by one commenter, a source would be free to use a Hg CEMS for control operations and use the sorbent
trap monitoring for compliance if it feels that such operational data is sufficiently critical to its control
operations. The addition of backup monitoring provides a further option for addressing the concerns
over data loss mentioned by the commenter. The EPA disagrees that the sorbent trap method cannot
work on a continuous basis at the emission limit levels in the final rule. While it is true that the potential
exists for increased capture of other stack gas constituents by the sorbent traps during long-term
monitoring, PS12B addresses this situation. As a result, achieving the monitoring method's
measurement performance requirements ensures data of known and acceptable quality. The EPA
disagrees that a systematic error exists between the Hg CEMS and sorbent trap technology. In fact, the
data from the EERC study definitively show that the agreement between the sorbent trap technology and
Hg CEMS at these low levels is significantly better than that required by the relative accuracy
specifications in PS 12A, which are consistent with those in the final rule. Also, with respect to PS 12B,
section 8.3.2, PS 12B is an approved regulatory requirement that has gone through notice and comment
rulemaking as an appropriate set of requirements for a sorbent trap monitoring system. The EPA is not
revising PS 12B as part of this rulemaking. The requirement to utilize the same type of sorbent material
in the sorbent trap monitoring system as will be used in the future for daily operations simply provides
for an additional check on the overall system and procedures. If Method 30B is employed as the
reference test method to conduct the relative accuracy testing, the tester may choose to use a different
sorbent for the Method 3OB sampling train to provide additional independence in the measurements. For
low level concerns, the EPA disagrees that the sorbent trap reference method (Method 30B) is unsuitable
to reliably perform RATA testing on electronic CEMS at low Hg emissions concentrations. Method 30B
is a performance-based method that is, in effect, self-validating each time it is applied and the method-
specific performance criteria are met. Moreover, recent testing conducted as part of the Utility MACT
ICR demonstrated that Hg concentrations well below 0.1 |ig/m3 (100 ng/m3) were reliably measured. In
addition, RATA requirements for Hg concentrations less than 0.5 |ig/m3 are a component of Appendix A
in the final rule and are known to be consistent with the measurement performance capabilities of
Method 30B. For NIST capability issues, see earlier response to Comments 27, 28, and 30.

Comment 37: Commenter 17757 suggests that quarterly performance tests and analyses of sorbent trap
monitoring data would be adequate to determine compliance with an annual emission limit.

Response to Comment 37: The EPA disagrees. Monitoring technology adequate to show continuous
compliance in accordance with the emission limit exists and is preferable to periodic emissions testing.
In other circumstances under the rule, the EPA has allowed for periodic testing, but in the case of Hg,
given the importance of this HAP from this sector and the availability of appropriate monitoring options,
the EPA reaffirms the proposal and has retained the continuous Hg monitoring provisions in the final
rule.

120


-------
Comment 38: Commenter 17775 supports use of sorbent trap monitoring systems and reliance on PS
12B, subject to the following comments. According to the commenter:

1.	First, the EPA should explicitly provide an option for use of backup monitoring systems to allow
sources to plan for the possibility of significant monitoring system failures where it is economical to
do so.

2.	Second, the EPA should provide a low emitter "breakthrough" specification in PS 12B and in 40
CFR Part 60, Appendix A, Method 3OB. According to the commenter, the current performance
specification for Method 3OB allows for 10 percent breakthrough for effluent concentrations above 1
[j,g/m3 and 20 percent for concentrations below 1 (J,g/m3, and as the actual effluent Hg concentration
approaches zero, this specification becomes virtually impossible to meet. The commenter asserts that
to compound the problem, PS 12B contains a breakthrough specification of 5 percent at all
concentrations. The commenter states that during testing for the 2010 ICR, RMB Consulting &
Research, Inc. identified this issue during testing at several plants with very low Hg emissions and
submitted a proposal to the EPA supporting use of an alternative specification at low concentrations
(see W. Roberson, RMB Consulting & Research, Inc., "Proposed Alternative Performance
Specifications for Method 30B" (June 14, 2010) (see (Attachment 10))). According to the
commenter, in the proposal, RMB illustrates with Method 3 0B data how failure of the specifications
is simply a matter of mathematics, because percent-based specifications lose meaning as results
approach zero, and RMB recommended that the EPA provide the following alternative performance
specifications for breakthrough: A) For concentrations < 0.5[j,g/m3 but >0.1 (J,g/m3, the alternative
breakthrough criteria could be < 50 percent of section 1 Hg mass; B) For concentrations < 0.1[j,g/m3,
there would be no breakthrough criteria and the validity of the samples would rest on all other
performance specifications being met.

According to the commenter, in response, the EPA staff indicated that, for the purposes of the 2010 ICR
testing, and for stack concentrations less than or equal to 0.5 |ig/m3, EGUs could consider Method 30B
data valid as long as it meets all other QA/QC criteria, even if it does not meet the section 2
breakthrough criteria of Table 9-1 of Method 3 0B but that the EPA indicated that approval of the
exception for the use of Method 30B when conducing RATAs or compliance tests would require
additional discussion within the agency. Commenter believes that a number of units being retrofitted
with baghouses and scrubbers may achieve Hg emissions levels below 0.5 |ig/m3. According to the
commenter, in order for sorbent trap monitoring systems to be available as an option, an alternative
breakthrough specification is needed in PS 12B. The commenter states that a consistent achievable
alternative specification also should be provided in Method 30B, and commenter requests that the EPA
promulgate those revisions concurrent with finalization of subpart UUUUU, or complete a rulemaking
to revise PS 12B and Method 30B well in advance of the subpart UUUUU compliance deadline.

Response to Comment 38: See the responses to Comment 7, above.

Comment 39: Comment 18449 states the continuous sorbent trap method has not been tested or
validated at the very low levels being proposed. According to the commenter, although they use
essentially the same method and technology, continuous sorbent tube measurements are even more
challenging than sorbent tube reference method measurements. The commenter states that cartridges
will be exposed continuously for (typically) 1 or 2 weeks, resulting in massive buildup of other stack
contaminants as compared to the short term (2 to 4 hour) exposure period of reference cartridges.
According to the commenter, the high levels of potential interferents that are co-eluted when the
cartridge is heated will challenge the performance of the analytical instrumentation.

121


-------
Commenter 18449 notes that a recent EERC study had what are probably the best possible sorbent trap
results. The commenter states that EERC took extraordinary care in running the samples, and the
manufacturer of the analyzer, Ohio Lumex, provided considerable support throughout the study. The
commenter states that agreement between the Tekran CEMS and the sorbent traps was very good, with
virtually no zero offset and a R2 value of 0.990. The commenter states that even under these best
possible conditions, there was a systematic 11 percent difference in sensitivity between the Tekran CEM
which used a NIST traceable elemental gas generator for calibration, and the sorbent traps, which used a
NIST traceable liquid solution for calibration. The commenter questions which was correct.

Commenter 18449 states that PS 12B is mentioned as the standard for continuous sorbent Hg monitoring
systems. The commenter provides that Section 8.3.2 under RATA testing, states that "The type sorbent
material used in the traps must be the same as that used for the daily operation of the monitoring
system." According to the commenter, the purpose of a RATA is to provide an independent test of the
validity of the continuous monitoring system's results, and if different sorbent types yield different
results, this is an indication of a severe problem somewhere. According to the commenter, it may be
desirable, from a user point of view, to use the same sorbent, but the commenter does not believe it
should be a requirement to do so.

Commenter 18449 provides the following comments with respect to the sorbent tube provisions:

1.	If Hg levels in the low ng/m3 range are set as the MACT limits, they would have to be RATA'd on a
regular basis. Commenter does not believe that the sorbent tube reference method has been
sufficiently validated at these low levels to establish that it could be used to reliably perform RATA
testing on electronic CEMS.

2.	NIST is incapable of measuring or certifying Hg concentrations in the low ng/m3 range. According
to the commenter, after 5 years of effort, the lowest point that NIST can certify is 0.5 |ig/m3 and
even this point can only be certified to an uncertainty of 6.1 percent. The commenter notes that this
level of uncertainty applies to the NIST calibrator only and that vendor and user calibrators would
have still higher uncertainties. Absent major developments, the commenter does not believe the
NIST traceable gases be available to validate low ng/m3 measurements.

Response to Comment 39: See response to Comments 32-36 above.

7. Provisions for Hg CEMS on bypass stacks.

Comment 40: Commenter 18023 states that the final rule should clarify the provisions for units with a
main stack and a bypass stack regarding use of the maximum potential concentration (MPC) for each
hour in which the bypass stack is used. According to the commenter, if this approach is used, the EPA
needs to clarify what value is used when Hg CEMS installed on a bypass stack measures a number
higher than the MPC. The commenter also asserts that the EPA should specify that when multiple units
are controlled by the same device and less than all of those units are being bypassed only the MPC for
the units being bypassed, should be reported. According to the commenter, MPC should not be used for
any of this since the MPC approach is only used for emission trading programs; a lower confidence
interval type of value should be used instead for conditions where a bypass stack is not monitored.

Comment 41: Commenter 17774 states that one difference between section 63.10010(a) and Appendix
A section 2 is the provision of an option for use of an assumed value during use of a bypass stack. The
commenter states that Appendix A section 2.4.2 provides for use of the "maximum potential
concentration" of Hg in lieu of installing an Hg CEMS or sorbent trap system on a bypass stack.

122


-------
According to the commenter, installation of CEMS on a bypass stack can be problematic from a number
of perspectives. According to the commenter, in addition to the costs of the additional monitoring
system, bypass stacks will not be used with sufficient frequency to perform those periodic QA tests that
require unit operation (e.g., RATAs and linearity checks). The commenter asserts that correlation of a
PM CEMS on a bypass stack would be nearly impossible to accomplish without significant operation
with bypass (since PS 11 requires a minimum of 15 runs).

Response to Comments 40-41: The EPA agrees with one of the commenters that the MPC approach
for bypass stacks is more suited to an emissions trading program. Rather than require the use of the
MPC to estimate emissions from the bypass stack, the final rule now requires use of one of two options:
(1) direct monitoring of both the main stack and the bypass stack for Hg or (2) counting of bypass hours
as hours of deviation from the Hg monitoring requirements. The EGU owner or operator remains subject
to the 30 boiler operating day rolling average during bypass operations. In addition, the final rule no
longer requires correlation of a PM CEMS according to PS 11. The monitor will be used as a PM
CPMS, although the final rule does provide for the use of a PM CEMS to determine compliance with the
filterable PM emission limit if the source elects to use this approach (see the final preamble for further
discussion).

8.	Provisions for bias adjustments.

Comment 42: Commenter 18023 states that the final rule should not require the bias test and bias
adjustment for Hg CEMS as proposed in section 4.1.1.5.3 because the Hg CEMS by nature exhibit drift
in both the positive and negative directions depending on the cause of the drift which is best corrected
through normal quality assurance activities, and basing adjustment of the hourly averages on a one-time
per year test would adversely affect data accuracy. According to the commenter, if a bias test were
required, it should quantify bias in either direction and allow for adjustment in either direction. The
commenter states that when stack gas flow is used for the mass calculations then non-bias adjusted flow
values should be used for that purpose.

Comment 43: Commenter 17805 agrees with the EPA that application of a bias adjustment for Hg
emissions is not necessary. It is the commenter's understanding that a bias adjustment, as used for SO2
emissions in the Acid Rain Program, was primarily intended to assist with ensuring emissions were
adjusted properly for cap and trade of emissions. According to the commenter, since Hg will not be
traded, the bias adjustment is not necessary.

Response to Comments 42 and 43: No bias adjustment or bias test is required under the final rule.

9.	General concerns.

Comment 44: Commenter 17621 states that the EERC of North Dakota conducted a study to investigate
the low-level measurement capabilities and variability of CMMs from Thermo Scientific and Tekran,
with support from EPRI, DOE, and the Illinois Clean Coal Institute. The commenter states that EPRI
reported that the quantification level of the Tekran system was 0.1 micrograms per normal cubic meter
(Hg/Nm3), compared to 0.4 ng/Nm3 for the Thermo Scientific system (EPRI, 2010b) and that these
concentrations are equivalent to about 0.1-0.4 lb/TBtu. The commenter states that Method 30B was
used as the basis for comparison, with extended sampling times used to reach the low levels of Hg. The
commenter asserts that based on this study, CMMs from both vendors can measure Hg accurately at the
proposed MACT limit for existing coal-fired EGUs but that CMM would neither be able to measure Hg

123


-------
accurately at the revised MACT limit for new coal-fired EGUs greater than or equal to 8,300 Btu/lb or at
the proposed limits for either existing or new liquid oil-fired EGUs.

Response to Comment 44: The final rule provides the option for use of either Hg CEMS or sorbent trap
monitoring systems. The EPA believes the record clearly shows these to be proven technologies, each
providing certain advantages. For existing and some of the new unit limit standards, the level of the
NIST traceable Hg standard is adequate and consistent with existing applications of Hg CEMS. For the
lowest new unit standard, the affected facilities may opt to use sorbent trap monitoring systems to
comply. As noted in a previous response above, there are data in the recent draft report entitled
"DETERMINING THE VARIABILITY OF CMMS AT LOW HG LEVELS", that demonstrate
reasonable performance of at least one Hg CEMS at Hg levels below 1.0 ug/m3 down to approximately
0.1 ug/m3.

Comment 45: Commenter 17747 states that the cycle time test unfairly excludes monitoring
technologies that can provide accurate mercury measurement. According to the commenter, Xact (the
commenter's proprietary testing technology) has demonstrated its ability to measure Hg accurately on
several different source types including coal-fired power plants. Commenter provided results of studies
on 585 MW coal fired electric generating facility equipped with ESP controls and located in the
northwestern United States. According to the commenter, these results demonstrated the Xact had a
relative accuracy of 3.53 percent, significantly better than the required 20 percent (figure 1 in comment
document). According to the commenter, Xact is designed to measure Hg by sampling stack effluent
nearly continuously, excluding only the time required for the tape to advance from the sampling area to
the analysis area (~ 20 sec). The sample is typically gathered for 15 minutes and then analyzed for 15
minutes to achieve detection limits that are appropriate for coal fired power plants, and this means that
concentration data is reported about 30 minutes after starting to gather the sample. According to the
commenter, the proposed cycle time would preclude the use of Xact. The commenter states that the key
issues are whether the instrument can measure Hg accurately and precisely and whether emissions are
nearly constantly monitored and that provided the technology can demonstrate these things, response or
cycle time is irrelevant.

The commenter notes that the current cycle time requirements are apparently based on what atomic
fluorescence-based instrumentation can do. Although this technology can deliver mercury concentration
data more quickly than XRF based technology, it can only measure mercury. The commenter notes that
the Xact, on the other hand, can measure mercury as well as several other metal hazardous air pollutants
(HAP) including (antimony, arsenic, cadmium, chromium, cobalt, lead, manganese, nickel, and
selenium). According to the commenter, this type of data is currently not available using any other
instrument, and it is unlikely that it could ever be obtained from any atomic fluorescence based
instrument.

The commenter notes that the proposed Hg monitoring performance specifications are inconsistent with
those already promulgated under PS 12A. According to the commenter, this performance specification
does not require a cycle time test, which indicates that EPA does not view a cycle time test as critical to
the performance requirements of a Hg CEMS. The commenter notes that the reason the EPA did give for
not using the PS 12A requirements is to "simplify compliance with the proposed rule by harmonizing its
monitoring and reporting requirements, to the extent possible with 40 CFR Part 75." According to the
commenter, this would include eliminating semiannual hard copy reporting of deviations along with data
assessment reports required by 40 CFR Part 60, where PS 12A resides, and cycle time does not play any
role in these more onerous reporting requirements. The commenter notes that the proposed EGU MACT
does allow for the use of PS 12B (sorbent trap monitoring) and that in this case facilities may sample for

124


-------
up to 14 days before ending the traps to a lab for Hg analysis. According to the commenter, this would
potentially allow 4-6 weeks to elapse before Hg data would be generated and reported, and it clearly
does not make any sense to allow up to 6 weeks or more for data to be reported under one method of
monitoring (sorbent traps) but require data every 15 minutes under another method (CEMS). Finally, the
commenter notes that because Hg health effects are chronic there is no health benefit associated with 15-
minute cycle times.

Response to Comment 45: The EPA agrees that the cycle time test requirements may be overly rigid
for integrated batch sampling-based Hg monitoring technologies, and we have made revisions to the
final rule to accommodate these technologies while still acquiring monitoring data at least once every
15-minutes consistent with our practice for CEMS.

Comment 46: Commenter 18428 states that an alternative to using CEMS for compliance, the EPA
should allow fuel sampling and analysis for Hg determining Hg emissions from coal-fired units,
particularly those with low coal Hg content. According to the commenter, this would be consistent with
the fuel sampling option for oil-fired units under the proposed rule, as well as the similar option
contained in the Industrial Boiler MACT rule.

Response to Comment 46: The fuel sampling option discussed in the proposed rule is no longer part of
the final rule because of technical issues with those proposed requirements. The final rule retains the
proposed approach for Hg monitoring, requiring either a CEMS or sorbent trap monitoring system, or
LEE testing for existing units with very low emissions.

Comment 47: Commenters 17724 and 17876 state that the CEMS the facility installed in preparation to
CAMR have significant reliability and operational issues (Hg, PM, HC1). Commenters 17724 and 17876
state that the EPA has left the long-term operational problems such as calibration gases to industry and
there are not accurate and reliable monitoring methodologies for demonstrating. Commenters 17724 and
17876 state the EPA purports to provide compliance flexibility while in reality there is very little
flexibility in light of the problematic and unproven nature of these monitoring technologies.

Commenter 17736 states the EPA cannot rely on unproven HC1 CEMS, that HC1 CEMS are not
commercially available to measure HC1 emissions from coal-fired EGUs, and no HC1 CEMS were used
to collect the data the EPA used to establish the HC1 standard.

Response to Comment 47: The agency disagrees with the commenters. As mentioned elsewhere, the
agency finds that the operation and maintenance issues for the CEMS mentioned are no different than
for other CEMS now in wide use and acceptance by the industry. The agency is aware that the
calibration gas issue is to be rectified well in advance of the rule's compliance date. The agency notes
that the rule is quite flexible with respect to compliance demonstration, containing numerous choices for
compliance, including the use of emissions testing alternatives for those EGU owners or operators who
remain concerned over use of CEMS or PM CPMS. The agency notes that FTIR CEMS exist now and
can be used to measure HC1 emissions continuously, that the HC1 emissions limit was developed from
emissions testing and has been adjusted to be appropriate for measurement with HC1 CEMS, and that
emissions testing options to demonstrate compliance exist for those EGU owners or operators who
choose not to use CEMS.

125


-------
5A06a - Testing/Monitoring: Application of Hg CEMS (Appendix A)

Commenters: 17725, 17770, 17795, 17796, 17800, 17820, 17821, 17881, 17886, 18449, 19114, 19121,
19122, 18023

1.	Rounding issues.

Comment 1: Commenter 17881 states that section 7.1.8.2 requires Hg mass emissions be reported as
pounds, to three decimal places. According to the commenter, this is not sufficient precision to allow a
meaningful comparison to the Hg emission limit for new coal-fired units (coal > 8,300 Btu/lb). The
commenter states that the Hg emission limit for such units is 0.0002 lb/GWh based upon the EPA's
05/18/2011 revised MACT floor analysis memorandum and that units as small as 25 MWe are affected
by the proposed EGU MACT, so compliance with the aforementioned new unit Hg limit would equate
to a mass emission rate of 0.000005 lb/hr. The commenter asserts that after rounding the preceding mass
emission rate, as pounds, to three decimal places, it will become zero, and that \anything as high as
0.0004 lb/hr will round to zero. Thus, according to the commenter, a unit as small as 25 MWe could
emit up to approximately 80 times the allowed Hg emission rate and yet still show compliance due to the
specified rounding precision in Appendix A.

Comment 2: Commenter 17881 states that section 7.1.9 indiscriminately requires that the Hg emission
rate records, in units of lb/TBtu or lb/GWh, be rounded to three decimal places. According to the
commenter, this requirement makes little sense, as all lb/TBtu emission limits in the proposed rule are
expressed to one decimal place, and several of the lb/GWh Hg emission limits are expressed to beyond
three decimal places. The commenter states that as noted in relation to section 7.1.8.2, the Hg emission
limit for new coal (> 8,300 Btu/lb) fired units is 0.0002 lb/GWh. According to the commenter, rounding
all calculated Hg emission rates to three decimal places would prohibit a meaningful compliance
determination with the preceding emission limit (i.e., an actual emission rate of 0.0004 lb/GWh, which
is twice the emission limit, would round to 0.000 lb/GWh, which is compliance with the emission limit).

Comment 3: Commenter 18449 states that under "Calculation of Mercury Mass Emissions" on page
25145 the rule requires that reported concentration averages for both CEMS and sorbent methods be
rounded, to the nearest tenth but that it is not clear how this would work with proposed MACT limits of
0.02 (J,g/m3, or how accurate 30-day rolling averages could be calculated with sources in the sub-
microgram range. The commenter states that it has existing customers that have short term
concentrations of 0.03 to 0.5 |ig/m3, which have been verified by RATA testing. According to the
commenter, hourly averages should be rounded to two or three significant figures, not tenths. The
commenter believes that reporting to more decimal points has no downside provided that violations are
defined as significant exceedances of the limit and that more accurate reporting would also give
customers due credit if they had low level emissions and had invested in the technology able to report
them.

Response to Comments 1-3: The EPA agrees with the commenters regarding the precision of the Hg
concentration values and the Hg emission rates. The final rule requires the hourly Hg concentrations and
emission rates to be reported to three significant figures, rather than specifying a particular number of
decimal places. The 30-day average Hg emission rates are to be rounded to two significant figures (i.e.,
the same precision as all of the Hg emission limits). We believe that these changes address the concerns
of the commenters.

2.	Calculating Hg emission rate.

126


-------
Comment 4: Commenter 17881 recommends the following items related to calculating the Hg emission
rate:

1.	Section 6.2.1.1 should be revised to explicitly note that fuel factors from 40 CFR Part 75, App. F,
section 3.3.5 or those derived consistent with the procedures in section 3.3.6 may also be used for
these calculations for calculating the Hg emission rate in units of lb/TBtu, According to the
commenter, this change is necessary due to the fact that Method 19 does not contain fuel factors for
subbituminous coals, petroleum coke or tire-derived fuels, and the provisions of section 12.3.2 of
Method 19 would therefore require fuel sampling and analysis in order to determine site-specific fuel
factors. The commenter states that the preceding would represent an unnecessary burden in light of
the EPA having already established fuel factors for these fuels under 40 CFR Part 75.

2.	Sections 6.2.1.2 and 6.2.2.2 of Appendix A relate to the calculation of Hg emission rates in units of
the applicable standard (i.e., lb/TBtu of lb/GWh). According to the commenter,, this section should
also describe the diluent capping procedure for start-up and shutdown, as allowed in section

63.10005(1). The commenter states that without reference to the preceding diluent capping
provisions, these sections would appear to always require the use of the actual measured diluent gas
concentration (in the context of section 6.2.1.2) or measured electrical load for the hour (in the
context of section 6.2.2.2).

3.	Section 6.2.2.2 should specify the use of the gross electrical output (consistent with the gross output
definition in section 63.10042) in order to eliminate any possible confusion as to the basis of the
MWh values to be used in the calculations (i.e., gross or net).

4.	The formulas for calculation of the lb/GWh Hg emission rate (i.e., A-2, A-3 and A-4) all include an
operating time component (th). It is not necessary to convert the Hg mass emission rate or the
average electrical load to a total integrated pound or load value for each clock hour. Rather, the Hg
mass emission rate and average electrical load can be used to directly calculate the Hg emission rate
in units of lb/GWh. (commenter references a formula "Consider the following substitution of
Equation A-2 into the term Mh in Equation A-4, and note that the term th cancels out, as it appears
in both the numerator and denominator:")

Response to Comment 4: The EPA agrees with items 1 through 4 in this comment and has made
corresponding changes in the final rule.

3. Grace period.

Comment 5: Several commenters (17770, 17820, 17886) note that part 75 has a grace period for system
integrity checks and recommend the same. Commenter 17820 states that the system integrity test is
likely to be one of the most challenging tests and if the test cannot be automated EGUs will need to
monitor operating hours to determine when a test will be due, and ensure that a qualified technician is
available to generate the oxidized Hg and ensure that the test is conducted properly. According to the
commenter, if the unit is not fully base-loaded, this will be difficult; most EGUs do not have technicians
available to perform routine tests on nights and weekends, and even if the test is scheduled to be
performed on time, issues with monitoring system breakdowns and the time necessary to complete
maintenance could also result in late tests. Commenter 17820 recommends an operating hour grace
period of at least 72 unit operating hours before data are invalidated, which would provide an EGU time
to schedule and perform a test if one were triggered.

Response to Comment 5: For concerns raised with the system integrity check requirement, the final
rule retains the weekly system integrity check requirement, without a grace period. However, to add
flexibility, the required frequency of the test has been changed from once every 168 operating hours to

127


-------
once every 7 operating days. Operating days are much easier to track than operating hours. The test can
be done at any time during the 7th operating day, rather than requiring it to be done at a certain hour. We
believe that this added flexibility will allow utilities to schedule the test in accordance with the
technician's work schedule.

4. Recordkeeping and reporting under Section 7 of Appendix A.

Comment 6: Commenter 17881 requests clarification of the recordkeeping and reporting provisions
contained in appendix A, section 7:

1.	The commenter states that it is unclear whether the requirements are meant to apply to the Hg CEMS
and sorbent trap monitoring systems, or all monitoring systems used to demonstrate compliance

2.	The commenter states that Section 7.1 requires that all measurements, data, et cetera, must be
maintained for a period of 5 years from the date of the record. According to the commenter, since
many of the auxiliary monitoring systems employed under Appendix A will also likely be subject to
40 CFR Part 75, the EPA should harmonize the data retention requirements with those found in 40
CFR 75.57(a), which requires that data be maintained for a period of at least 3 years from the date of
each record. According to the commenter, having two different retention schedules for the same data
elements (i.e., flow rate data, diluent data, etc.) will simply lead to confusion and potential non-
compliance, especially in cases where a facility currently has well established procedures to purge
various Part 75 data elements after the required 3 year period.

3.	The commenter states that the EPA should clarify that none of the provisions in section 7.1.1 and
related sub-sections apply to those auxiliary monitoring systems which are subject to 40 CFR Part
75, as many (if not all) of these requirements are duplicative of those that already exist within 40
CFR Part 75.

4.	The commenter questions the rationale for some of the requirements to be reported in the context of
Hg emissions monitoring. The commenter provides an example of megawatt ratings under section
7.1.1.2.1; according to the commenter, the EPA makes the presumption that all individual units have
a defined megawatt output, which is not correct. According to the commenter, In those cases where
multiple units share a common steam extraction turbine and electrical generator, steam output is
often the basis for the individual unit ratings, and this approach is clearly allowed under 40 CFR Part
75 (refer to section 75.53(e)( 1 )(i)(I)). The commenter also states that the basis for any load rating
must be specified (i.e., net or gross).

5.	The commenter notes that under section 7.1.1.2.1 the identification of controls should be specific to
those types of controls which have relevance under 40 CFR part 63, subpart UUUUU and that these
would include acid gas controls, PM controls and Hg specific controls. Thecommetner questions
how the collection of information on NOx controls, for example, would be relevant under the
proposed EGU MACT.

6.	According to the commenter, formulas used to calculate emissions and heat input under section
7.1.1.2.1 only need formulas which are specific to the determination of the Hg emission rate in units
of the applicable standard. The commenter also states that the calculation of heat input is not
required to support the Hg emission rate determination, and this reference should be removed from
the rule.

7.	The commenter states that Section 7.1.2 relates to various operating parameter records which must
be maintained "to the extent that these data are needed to convert Hg concentration data to the units
of the emission standard". According to the commenter, rather than leaving it to the discretion of the
regulated entity to determine whether certain data elements are needed, the EPA should clearly
specify which data elements are necessary for each of the Hg emission limit forms (i.e., lb/TBtu and
lb/GWhr).

128


-------
8. The commenter states that Section 7.1.5.2.5 also requires the reporting of hourly PMA, which is not
appropriate when missing data substitution is being prohibited.

Response to Comment 6: For item 1, appendix A applies to any Hg CEMS or sorbent trap monitoring
system, as well as any other auxiliary monitoring required to report emissions in terms of the standard.
As suggested in item 3 of this comment, the final rule clarifies that where such auxiliary systems are
used, the recordkeeping provisions of part 75 generally apply to those systems. As in the proposal, one
exception to that rule is that, consistent with the general recordkeeping provisions under the Part 63
NESHAP program, records used to demonstrate compliance with this rule must be kept for 5 years. For
items 4 through 6, revisions in the final rule directly address these concerns and streamline the specific
records that apply. For Item 7, the EPA has left the "as applicable" language as proposed; the reporting
system will provide for capturing the correct information based on each emission limit. For item 8, just
because the rule does not specify a minimum data availability requirement, does not mean that
information on percent monitor availability is unnecessary. This information will be used to ensure that
sources continue to operate and maintain their monitoring systems in accordance with the requirements
of section 63.10020(b) and the general monitoring operation provisions that apply across part 63.

5. Recommendations - Appendix A.

Comment 7: Commenter 17725 recommends that the EPA add a subsection to Appendix A section
7.1.5.2.3 that clearly states that 40 CFR Part 75 data substitution procedures and bias adjustment factors
are not to be used with the hourly average volumetric flow rate used by a sorbent trap monitoring
system.

Commenter 17795 recommends the following changes to Appendix A:

1.	The commenter states that Section 3.1.12 should be rewritten to allow the use of the closest upscale
gas from actual stack concentrations and that currently, the proposal suggests implementing a Hg
monitor span of 0-10 ug/m3. According to the commenter, for existing units > 8300 Btu/lb to
demonstrate compliance with the proposed limits, Hg concentrations would need to be less than 1.2
ug/m3, and therefore the low level calibration gas would be closer to actual emissions and should be
used as the daily calibration standard (20-30 percent of span value).

2.	The commenter recommends quarterly, instead of weekly, oxidized Hg (Hg+2) converter checks.
According to the commenter, NIST-traceable Hg+2 in the Tekran Hg monitoring systems is
currently limited to -2.5 ug/m3, but Hg+2 will be < 0.5 ug/m3 after controls to achieve compliance
with the proposed standards. According to the commenter, quarterly checks will be more than
sufficient at these levels. The commenter states that a weekly requirement was understandable for
the trading program that would have been adopted for the CAMR where Hg+2 could exist in the gas
stream of units purchasing of Hg allowances, but for this program Hg+2 won't be quantifiable for
units in the > 8300 Btu/lb category. According to the commenter, calibrating a system at more than 5
times the measurable concentration would produce accuracy problems and filter contamination if
conducted weekly at these levels.

Response to Comment 7: The EPA sees no need to add a subsection to section 7.1.5.2.3 of Appendix A
as section 4.1.2.4 of Appendix A clearly states that bias adjustment is not required for sorbent trap
monitoring system data. The EPA does not believe that allowing a low-level gas to be used for daily
calibrations is necessary. Appendix A provides sufficient flexibility in setting the Hg CEMS span value
and selecting calibration gases. The span value is set starting with the Hg concentration (|ig/m3)
corresponding to twice the level of the standard. This value is then rounded upward, either to the next

129


-------
highest integer, the next highest multiple of 5 |ig/m3, or to the next highest multiple of 10 |ig/m3. For
instance, if the level of the standard corresponds to a concentration of 1.2 |ig/m3, as suggested by the
commenter, the span value could either be set at either 3 |ig/m3, 5 |ig/m3, or 10 |ig/m3. If it is set at 3
|ig/m3, a mid-level calibration gas with a concentration of 50 to 60% of the span value (i.e., 1.5 to 1.8
|ig/m3— which is in close proximity to the level of the standard) could be used for daily calibrations. We
believe this addresses the commenter's concerns.

Regarding the system integrity check, the EPA does not agree with the commenter that a quarterly test
frequency is sufficient. To obtain accurate data with a Hg CEMS that has a converter, you must ensure
that the converter is working properly. The system integrity check provides that assurance. Therefore, it
is not appropriate to allow long time intervals between converter checks. If a quarterly test frequency
were implemented, there could be more than five months between successive system integrity checks,
e.g., if the test is done in early January (1st quarter) and the next one is not done until late June (2nd
quarter). This level of quality-assurance for monitoring a HAP such as Hg is unacceptable.

Comment 8: Commenter 17796 states that the QA procedures for Hg CEMS outlined in CAMR and
duplicated in Appendix A of the proposal are appropriate for determining that the unit is providing
accurate results and should not be changed because now compliance is based upon an emission limit and
not a yearly mass for trading purposes in CAMR.

Response to Comment 8: While the EPA agrees in many respects, we have made certain changes to the
CAMR-based Hg monitoring procedures as appropriate, such as not using bias adjustment factors and
not relying on data substitution practices.

Comment 9: Commenter 18023 states that under section 3.2.3.3, to provide for efficiency, the option
should be provided to allow the use of monitors already installed and certified under part 60 or 75
without any additional requirements.

Response to Comment 9: The commenter is referring to the additional monitoring systems described in
sections 3.2.3.1 and 3.2.3.2 (not section 3.2.3.3, which addresses monitor span and range). These
additional monitors (i.e., diluent gas, flow rate, and moisture) are needed to convert Hg concentrations to
the units of the emission standards. The final rule mandates that all of these monitoring systems be
installed, certified, operated, and maintained according to 40 CFR Part 75 (see §§63.10010(b) through
(d)), and that the data from these monitoring systems be reported using the ECMPS Client Tool. Nearly
all coal-fired utilities already have these monitors in place to meet Acid Rain Program requirements. The
final rule makes it clear that no additional certification testing is required under Subpart UUUUU for
previously-certified Part 75 systems that are continuing to meet Part 75 QA requirements (see
§63.10005(d)). Note, however, that the use of Part 60 monitors is not allowed—these monitors must
either be replaced or upgraded to meet Part 75 requirements.

Comment 10: Commenter 17820 generally supports the EPA's attempt to provide consistency between
this proposal and Part 75 but notes that not all of the part 75 requirements are necessary in this context.
Some of these concerns include:

1. Commenters 17820 and 17800 note that while the EPA proposes ongoing QA requirements for Hg
CEMS in Appendix A, the rule proposes in section 63.10021(1)(14) to require compliance with
quarterly accuracy determinations and calibration drift tests in accordance with Part 60, Appendix F,
Procedure 5. According to the commenters, the quarterly and daily requirements in Procedure 5 are
duplicative of and conflict with some of the proposed requirements in Appendix A, and use of

130


-------
Procedure 5 is inconsistent with the EPA's preamble statement that it considered and rejected using
Procedure 5.

2.	The commenter opines that two provisions from Part 75 that could help improve data availability are
the provisions for use of back up monitoring systems and the provisions for use of conditional data
validation. According to the commenter, these options have been used under Part 75 for years
without any reduction in data quality, and the EPA should include provisions in Appendix A to
allow use of similar procedures.

3.	The commenter opines that the EPA should include back up and like-kind replacement monitoring
system options similar to Part 75 in Appendix A. According to the commenter, including specific
provisions will avoid the need for future guidance and/or unit-specific petitions if cases arise where a
backup or replacement is needed.

4.	The commenter states that Section 75.20(b)(3)(ii) allows sources that have made a change to a
monitoring system that requires additional testing (e.g., repairs, replacements, adjustments,
linearization, reprogramming, relocation, etc.) to conditionally validate data prior to completion of
all required tests by performing a successful "probationary calibration error test." According to the
commenter, this provision has been crucial to maintaining good data availability under Part 75, by
avoiding invalidating data after a monitoring system has been confirmed to be operating properly but
before all of the required confirming tests can be scheduling and completed.

Response to Comment 10: The final rule removes the references to Procedure 5 and adopts the part 75
options discussed in items 2 through 4 of this comment.

Comment 11: Commenters 19121 and 19122 support the monitoring requirements for Hg outside of
part 75. However, the commenters recommend the following changes to Appendix A:

1.	Commenters recommend amending the minimum requirement in section 3.1.16 (RATA) of nine valid
test runs be reduced to a minimum of three runs (six samples) to show compliance. Commenters also
recommend that a similar reduction in paired runs apply to certification and recertification events in
other applicable Part 60 rules.

2.	With respect to alternative 2 for accounting for gas moisture content under section 3.2.3.1
commenters believe that the moisture value need not be limited to the most recent Hg emissions test.
Commenters recommend that any test event that requires a Method 4 analysis to be performed such as a
CEMS RATA or Method 4 particulate test result be a valid representation of the stack moisture
condition.

3.	Commenters recommend that "significant percentage" language in section 5.1.5 be more clearly
defined. The commenters believe that it is likely infeasible to perform a diagnostic linearity check within
168 hours of a span change as it would require that the Hg calibration gas generators' output values be
adjusted by the manufacturer to the new linearity requirements which require new NIST certification of
the generators. Thus, according to the commenters, the time needed to ship the calibration gas generators
to the manufacturer, modify and recertify the generators can take longer than 168 hours. Commenter
19121 recommends that owners/operators have 30 operating days to perform a diagnostic linearity check
after change of span value.

4.	Commenters recommend that if CO2 and flow data is available, the procedures in 40 CFR Part 75 be
used to calculate the Hg emission rate instead of the current section 6.1.3 that states "for any operating
hour in which valid data are not obtained, either for Hg concentration or for a parameter used, in the
emissions calculation, or moisture, as applicable, do not calculate the Hg emission rate for that hour."

131


-------
5. Commenters recommend the EPA incorporate by reference parts of Part 75 that are used to determine
Hg emission rate calculations in section 7.

Response to Comment 11: Regarding changes 1) through 5) suggested by the commenters:

1.	At this time, the EPA has no intention of reducing the minimum number of test runs for the RATA of
a Hg CEMS from nine to three, as recommended by the commenters. The nine run RATA is a well-
established procedure that provides a robust statistical basis for determining the accuracy of a CEMS,
and is familiar to, and widely accepted by, the regulated community and source testers. The commenters
provided no data to support their claim that three runs (as opposed to nine) are sufficient to assess
relative accuracy. Without such demonstration data, a change in the RATA procedures is unwarranted.
Further, the commenters' broad recommendation to extend the proposed reduction in the number of
paired runs to "certification and recertification events in other applicable Part 60 rules" is beyond the
scope of this rulemaking.

2.	Sections 63.10010(b) through (d) of the final rule specifies that all of the additional monitors needed
to convert Hg concentrations to units of the emission standard must meet the requirements of 40 CFR
Part 75. To account for stack gas moisture content, Part 75 provides three possible compliance options:
(a) install and certify a continuous moisture monitoring system; (b) use a fuel-specific default moisture
value from §75.11(b); or (c) petition the Administrator under §75.66 for a site-specific default moisture
value. Under option (c), the proposed default value could be based on Method 4 data collected either
during historical stack tests or CEMS RATAs.

3.	Proposed section 5.1.5 of Appendix A has been renumbered as section 5.1.6 in the final rule, and has
been made consistent with sections 2.1.1.5 and 2.1.2.5 of 40 CFR Part 75, Appendix A, regarding span
adjustments. The proposed requirement to perform a diagnostic linearity check within 168 operating
hours after changing the span of a Hg analyzer has been retained, but a clearly defined window of time
in which the span change must be implemented has been added. The owner or operator has up to 90 days
after the end of the calendar quarter in which the need for a span change is identified to implement the
span adjustment.

4.	The EPA has not incorporated the commenter's recommendation. The final rule retains the statement
in section 6.1.3 of Appendix A prohibiting calculation of Hg emission rates when valid data for one or
more parameters are not available. This is consistent with a long-standing position that compliance with
emission rate limits must be based exclusively on actual, measured data—i.e., the use of substitute data
is not appropriate for Part 60 programs (for example, see statements to this effect in NSPS Subpart Da).
This is in contrast to emissions accounting programs such as the Acid Rain Program, which require
pollutant mass emissions to be reported for every unit operating hour, in accordance with 40 CFR Part
75. During monitor outages, Part 75 requires substitute data values to be used in the calculations. Note
that even if EPA had decided to allow the use of substitute data during Hg monitor outages, the
commenter's suggested calculation approach could not have been implemented, because all of the Hg
monitoring provisions of Part 75 have been removed from the rule in response to the vacature of the
Clean Air Mercury Rule (CAMR) (see 76 FR 17301, March 28, 2011).

5.	The EPA has incorporated the commenter's suggestion to simplify section 7 of Appendix A by
referencing relevant sections of Part 75, but only for the additional monitoring systems that are needed
to convert Hg concentration to units of the standard (i.e., diluent gas, flow rate, and moisture systems).
Similar cross-referencing of Part 75 is not possible for Hg emission rate calculations because, as
explained in the previous paragraph, Part 75 no longer includes Hg monitoring provisions.

132


-------
Comment 12: Commenter 17800 states that the EPA needs to remove the requirement for a NIST
traceable oxidized Hg standard from the certification tests (see 86 FR 25034). The commenter is not
aware of any oxidized standard for Hg, let alone a "NIST-traceable oxidized Hg standard".

Response to Comment 12: The definition of a "NIST-Traceable Source of Oxidized Hg" in section
3.1.5 of Appendix A refers to a generator that: (a) is capable of providing known concentrations of
vapor phase mercuric chloride and (b) meets the performance requirements of the interim version of the
"EPA Traceability Protocol for Qualification and Certification of Mercuric Chloride Gas Generators".
That traceability protocol was developed with significant input from industry, consultants, and vendors
of Hg CEMS. The protocol does not provide NIST traceability through an unbroken chain of
comparisons for the oxidized Hg calibration gas, but rather establishes NIST traceability for chemical
reagents used to produce the calibration gas (such as HgCh solutions or chlorine gas cylinders), and for
individual components of the gas generator which measure these reagents in the process of producing
the gas, e.g., weighing and mass flow meters. This approach represents the current "state of the art" and
has been agreed upon by EPA and industry as an interim methodology. Further research is needed to
develop direct NIST traceability for oxidized Hg calibration gas standards.

Comment 13: Commenter 17821 states that section 3.2.1.4.3 proposes to require that the full "range" of
the Hg analyzer be capable of measuring the MPC values that are defined in section 3.2.1.4.1.
Commenter encourages the EPA to define the MPC value as the "span" and "range" of the Hg CEMS
and suggests that this value be used as the basis for determining calibration and linearity gas values and
calibration errors. According to the commenter, modern Hg CEMS are based on digital technology and
do not have "span ranges" built into the technology like the older analog analyzers of the past. The
commenter states that they do have analog outputs that can be scaled such that a zero and full scale
value can be defined to match with the 4-20 mA output signal used for data recording, but that this
setting is not a span range setting in the analyzer. According to the commenter, modern Hg analyzers
have a measurement range that is limited only by the lower and upper detection limits of the
measurement sensors within the analyzer. Commenter understands the need to determine the accuracy of
an Hg analyzer and the need to determine calibration and linearity errors. However, according to the
commenter, defining an arbitrary value for "span" is meaningless to a modern Hg analyzer, and a better
method would be to utilize a standard "span" value for all Hg CEMS used in compliance with these
proposed rules. (Commenter provides an example.)

Comment 14: Commenter 17821 recommends that the EPA define the "range" of the Hg CEMS as a
range from zero to the appropriate MPC (see section 3.1.13). According to the commenter, a source
would then perform linearity checks "across the range as determined by these rules" instead of across
the analyzer's entire measurement capability. The commenter states that modern Hg analyzers have a
large measurement range, and the commenter does not believe that EPA intended for sources to test the
analyzer across its entire range of measurement but rather across the "span" or full "range" defined for
use with compliance of these proposed rules.

Response to Comments 13 -14: The commenter appears to misunderstand the terms "span" and
"range" as they are presented in Appendix A. The purpose of the span value is to determine the
appropriate calibration gas concentrations for daily calibrations and linearity checks—these
concentrations are all expressed as percentages of the span value. To comply with the stringent Hg
emission limits in subpart UUUUU, Hg concentrations must be reduced to very low levels. Section
3.2.1.4.2 of Appendix A requires the span value to be set by multiplying the Hg concentration
corresponding to the standard by two, and then rounding off the result appropriately. Flexibility is
provided; the span value (in units of |ig/m3) may be rounded to either the next highest integer, the next

133


-------
highest multiple of 5 |ig/m3, or the next highest multiple of 10 |ig/m3. If better accuracy at the lower end
of the scale is desired, rounding off the span value to the next highest integer or multiple of 5 |ig/m3 may
be preferable to rounding to the next highest multiple of 10 |ig/m3, because calibration gases closer to
the level of the emission standard will be used for daily calibrations and linearity checks (see the
response to Comment 7, above). The EPA recognizes that low Hg concentrations are often attainable
only by operating wet scrubbers and/or carbon injection systems, and that it is possible for these
emission controls to malfunction. During control device malfunctions, Hg concentrations may approach
the level of the maximum potential concentration (MPC). Therefore, section 3.2.1.4.3 of Appendix A
also requires the Hg analyzer to be capable of reading Hg concentrations as high as the MPC.

Comment 15: Commenter 18023 states that section 3.1.7 requires the span value to be set to
approximately twice the concentration corresponding to the emission standard and alternatively
rounding the span value to the next highest interval of 10. According to the commenter, based on the
emission limit stated in the current draft rule, this would restrict the span value to either 2 |ig/m3 or 10
[j,g/m3. Commenter recommends that they should be allowed to set the span value anywhere between 2
and 10 [j,g/m3 as long as that range falls within acceptable limitations of the NIST traceable calibrator.
The commenter states that the EPA also proposes that the full-scale range should be set to include the
MPC. According to the commenter, the EPA should allow the full-scale range to be set at one number
(10), and perform quality assurance testing over a lower portion of that range (0- 5). The commenter
also states that 40 CFR part 75 has an annual requirement for the majority of analyzer readings to be
between 20 and 80 percent of full-scale, which should not apply to Hg.

Response to Comment 15: In the final rule, greater flexibility in setting the span value is provided; the
span value (|ig/m3) is twice the Hg concentration corresponding to the emissions standard, rounded to
either the next highest integer, the next highest multiple of 5 |ig/m3, or the next highest multiple of 10
|ig/m3. For certain existing units, the estimated Hg concentration corresponding to the standard is about
1.5 |ig/m3. Therefore, the span value could be set to either 2.0, 5.0, or 10.0 |ig/m3. If the span value is set
at 5.0 |ig/m3, the required QA tests (i.e., daily calibrations, linearity checks and system integrity checks)
will be performed in the 0-5 |ig/m3 portion of the measurement scale (as suggested by the commenter).
Then, provided that the analyzer is capable of reading Hg concentrations as high as the MPC, the span
and range requirements of sections 3.2.1.4.1 through 3.2.1.4.3 of Appendix A will be satisfied. The final
rule does not require the majority of the Hg concentration data to be within 20 to 80% of the analyzer's
full-scale range.

Comment 16: Commenter 17821 opposes the requirement under section 3.2.3.3. to set the span for a
CO2 monitor at a value of 1.25 times the maximum potential value for these flue gas components.
According to the commenter, typically, a coal-fired source has a maximum potential CO2 concentration
of approximately 14 percent in the flue gas, and 1.25 times 14 is only 17.5%. The commenter states that
other regulations, such as 40 CFR 60 and 40 CFR 75, require the span of a CO2 monitor to be set at 20
percent. According to the commenter, the difference between these established rules and this proposal
results in a conflict of span settings which would require sources to either install and operate a separate
CO2 monitor for compliance with these proposed rules, or conduct a separate span calibration check on
an existing CO2 monitor in order to comply with all applicable requirements. Commenter encourages the
EPA to define a span of 20 percent for CO2 monitors used for compliance with these proposed rules.

Response to Comment 16: The final rule does not include the requirement to set the CO2 monitor span
at 1.25 times the MPC. Section 63.10010(b) requires that all diluent gas monitors used to provide data
under Subpart UUUUU must meet the requirements of 40 CFR part 75. Part 75 span values for C02 or
O2 monitors are therefore acceptable for Subpart UUUUU and there is no conflict between the

134


-------
regulations. Essentially all coal-fired utility units already have certified part 75 CO2 or O2 monitors in
place to meet Acid Rain Program requirements.

Comment 17: Commenters 17821 and 17881 object to the requirement at section 7.2.5.1 to submit
quarterly Hg monitoring data. According to the commenters, this rule is not based on a cap-and-trade
program but on compliance with emission limitations and structured around excess emissions and
deviation reporting. The commenters opine that under those types of compliance programs, there is no
need for sources to submit hourly monitoring data, along with the other data that is required by this
section and later subsections. Commenter 17881 states that the EPA does not justify the requirement to
electronically submit data under section 7.2.4.

Response to Comment 17: The EPA disagrees. These provisions provide extremely useful compliance
oversight information regardless of whether compliance is market-based or emission limit based. With
the existing structures built around Part 75 reporting for these sources, reporting these data through the
ECMPS mechanism is an efficient means of ensuring these records are maintained and available for
review. Having an hourly record of unit operating time, measured emissions, and monitor outages
provides added assurance the emission limits are being met. Electronic audits can be performed to verify
that the 30-day rolling average emission rates are being calculated correctly nationwide.

Comment 18: Commenter 18449 states that the Appendix A Performance Specification appears to
replace PS-12A in this MACT but not in the other recently prepared MACT rules. According to the
commenter, the previous PS-12A document had been created with considerable input from many
sources and had undergone several revisions, has worked well for the last 6 years, and required only
minor corrections. The commenter states that this new document is an attempt to reconcile some old Part
60 concepts with the second generation CEMS performance specs of the PS series, and in particular
combines PS-12A, PS-12B and Procedure 5. According to the commenter, Appendix A mingles Hg
monitor performance requirements, which are a function of the continuous Hg monitor, with higher level
Hg reporting requirements, which are implemented as higher level functions of the DAS.

Response to Comment 18: The commenter is correct that Appendix A of this rule contains the Hg
CEMS and sorbent trap system requirements for Hg monitoring for this rule; the rule does not reference
or rely on PS-12A. In addition, Appendix A contains specific recordkeeping and reporting requirements
for Hg monitoring data to support entry of the data into ECMPS.

In particular, the final rule requires all CEMS data to be submitted to EPA using the ECMPS Client
Tool. The Hg monitoring requirements in Appendix A, which closely resemble the provisions of the
vacated CAMR regulation, have been retained in the final rule. Certification and on-going QA
provisions like those in Appendix A went through public comment during the CAMR rule making, were
published in Part 75 (but have since been removed), and were designed to be implemented through
ECMPS. PS 12B is referenced as it is essentially identical to the former Appendix K of Part 75, which
was to be implemented through ECMPS under CAMR.

Comment 19: Commenter 18449 states that the requirement to report readings of either CO2 of O2, on
any constant basis is unnecessary. The commenter states that Hg monitors (or any other pollutant
monitor) always report concentrations, either volumetrically (ppm, ppb) or m/v basis (ug/m3). Most
CEMS are diluting and report on a wet basis. According to the commenter, the emission limits are given
as a mass emission limit per unit of plant activity, and the correction of the pollutant output
concentration to a specific CO2 or O2 concentration does not in any way facilitate this calculation but
adds unnecessary variables that will increase the uncertainty and calculation error. The commenter states

135


-------
that corrected (CO2 or O2) pollutant concentrations are not used in any of the subsequent mass emissions
calculations being proposed by the EPA for concentration based Hg analyzers.

The commenter states that stack velocities determined using pitot tubes or other measurement devices
are not measured on a constant O2 basis. Thus, according to the commenter, the stack volumes would
need to be recalculated on a 7 percent O2 basis in order to allow calculation of the mass emission rate.
The commenter states that the sorbent trap reference method does not report concentrations on a 7
percent O2 basis and that thus both the reference and CEMS values would have to be corrected to 7
percent O2. According to the commenter, if the Hg CEMS intrinsically produces a concentration
corrected to 7 percent CO2, these results must be back corrected to yield an as-is value to allow
comparison. This is a needless step that complicates matters and introduces errors. The commenter states
that most existing CEMS do not have an O2 monitor. According to the commenter, it is unnecessary and
punitive to require the addition of an O2 monitor to a Hg CEM, which will reduce reliability and
accuracy of the overall system. According to the commenter, all commercially available dilution-based
Hg CEMS analyzers are capable of directly determining their own dilution ratio by injecting Hg
calibration gas at various points within the system, which means that the use of CO2 or O2 as a dilution
ratio check is not required.

Response to Comment 19: The commenter appears to be objecting to the use of diluent gas, flow rate,
and other parametric measurements to convert Hg concentrations to the units of the emission standards.
If so, his comments are misdirected. He purports to be commenting on Appendix A, but is actually
objecting to the units of the emission standards, which EPA has no intention of revising at this time. In
order to express a measured Hg concentration in units of lb/TBtu, an equation from EPA Method 19 is
used. The Method 19 equations all contain a diluent gas concentration term and some of them require
corrections for the stack gas moisture content. The commenter's assertion that an 02 monitor is required
in incorrect; the final rule allows the diluent monitor to measure either O2 or CO2. Finally, if you elect to
(or are required to) demonstrate compliance with an electrical output-based Hg limit, a diluent monitor
is not required at all—only a flow monitor is needed in that case.

Comment 20: Commenter 18449 states that under the RATA testing section 4.1.1.5 the procedure
should require only that the CEMS and reference results be converted and compared to each other on a
consistent basis. According to the commenter, the reference method does not report on a diluents basis
and Hg analyzers will not report on this basis, and thus any requirement to correct to some reference
CO2 (or O2) basis needlessly complicates the RA testing.

Response to Comment 20: The EPA agrees with the commenter that for the purposes of this rule, the
Hg monitor should be assessed on the basis of how accurately it measures Hg concentrations. Therefore
the RATAs must be done on a concentration basis, comparing the |ig/m3 readings from the reference
method to the |ig/m3 readings from the monitor. This is clearly stated in sections 4.1.1.5.2 and 4.1.2.4 of
Appendix A.

Comment 21: Commenter 19114 states that the EPA appears to have overlooked many of the issues that
were resolved in the earlier CAMR rulemaking process. The commenter attached its 2005 CAMR
comments to further address issues that had previously been addressed in the previous CAMR
rulemaking. Some issues identified by the commenter include:

• According to the commenter, the proposed rule does not address the handling of negative values.
The commenter recommends that negative values be rounded to zero and use an associated code
to indicate the change, which the commenter states is similar to how Part 75 handles negative

136


-------
data. According to the commenter, if instrument drift and allowable calibration error tolerances
are included, it is possible to be within the analysis tolerance and read a legitimate negative
value.

•	Commenter recommends the use of part 72 definitions for C02 and flow range determination and
the definition for zero gas because, according to the commenter, part 72 is more accurate and
provides harmonization between the two rules.

•	Commenter recommends an additional option be available for measuring moisture. According to
the commenter, if the stack is saturated, a source should be able to use temperature, absolute
pressure, and a psychrometric chart to measure moisture. The commenter states that temperature
and pressure transmitters can be calibrated with NIST traceable equipment, and a RATA could
be performed but would be unnecessary. According to the commenter, during periods when the
stack is not saturated, default factors listed in the rule could be used.

Response to Comment 21: Regarding the three issues raised by the commenter:

1.	This issue can be handled through the ECMPS Reporting Instructions. There is a Method of
Determination Code (MODC) in Part 75 (i.e., MODC "21"in §75.57, Table 4a) that addresses the
handling of negative values. The EPA will instruct sources to use MODC 21 and report zero Hg
concentration when a negative value is read by a CEMS that is not out-of-control.

2.	There are no definitions for "CO2 and flow range determination" or for "zero gas" in 40 CFR Part 72.
The closest thing to either of these terms is the definition of "zero air material" in section 72.2 In view
of the confusion of terms and incorrect rule citations, EPA is unable to provide a meaningful response to
this comment.

3.	The final rule allows the "additional option" for measuring moisture described by the commenter. In
cases where the Hg emissions calculations require corrections for moisture, affected sources must
account for the stack gas moisture content in accordance with 40 CFR 75.11. The affected source may
either: (a) install and certify a continuous moisture monitoring system; (b) use an applicable fuel-
specific default moisture value provided in §75.11(b); or (c) petition the Administrator for permission to
use a site-specific default moisture value. One of the allowable Part 75 continuous moisture monitoring
systems under option "(a)" consists of a temperature sensor and a psychrometric chart, and applies only
to saturated gas streams.

Comment 22: Commenter 18023 states that with respect to section 3.2.3.1 Heat Input-Based Emission
Limits, when Hg and the diluents (C02 or 02) are measured on different bases (i.e., one wet and the
other dry), stack moisture would need to be accounted for. If, however, they are measured on the same
basis, asserts the commenter, a stack moisture monitoring system would not be required.

Response to Comment 22: The commenter's statement is true, but the EPA sees no need to make any
changes to the rule text. Section 3.2.3.1 of Appendix A clearly states that "in some cases" stack gas
moisture content must be considered. The need for moisture correction (or lack thereof) depends entirely
on which Method 19 equation is used to calculate the Hg emission rate. The selected Method 19
equation, in turn, depends upon the measurement basis (wet or dry) of the pollutant and diluent gas
species. Therefore, it will be obvious to the affected sources if and when moisture corrections are
needed.

Comment 23: Commenter 17881 states that the requirements of section 63.10010 for main and bypass
stacks conflict directly with those in Appendix A (section 2.4.2 of Appendix A allows installation of a

137


-------
CEMS on the main stack and the use of maximum potential Hg concentration whenever the bypass stack
is utilized). The commenter states that EGUs with multiple stack or duct configurations are addressed in
section 63.10010(a)(5). The commenter appreciates the flexibility afforded in this paragraph but opines
that the EPA should specify the method used to merge the multiple stacks or duct values into a single
value which could then be compared to the emission limit. According to the commenter, in the absence
of such guidance, it could be construed that each monitoring location must independently show
compliance with the applicable EGU emission limits, and this could result in situations of seeming non-
compliance. The commenter questions whether, for example, if Hg monitoring is conducted in A and B
ducts associated with a single EGU and one duct monitor shows a compliance value (75% of the limit)
while the other duct monitor does not (105% of the limit), compliance actually would be assessed and
whether the two duct values should simply be averaged arithmetically, in a flow weighted manner, etc.

Response to Comment 23: For a unit with multiple parallel control devices with multiple stacks or
ducts where all stacks or ducts are monitored, section 63.10010(a)(6) of the final rule states that the
pollutant emission rate for the unit must be calculated, weighted by stack gas volumetric flow rate,
where the weighted average emission rate is calculated according to section 63.10010(a)(6).

Comment 24: Commenter 17881 states that span values for auxiliary measurement systems (i.e., flow
rate, diluent gas and moisture monitors) in section 3.2.3.3 contain undefined terms such as maximum
potential flow rate and maximum potential concentration. The commenter notes that these provisions are
on the surface similar to those found in 40 CFR part 75, albeit without much of the detail necessary to
implement the provisions (i.e., how is the maximum potential flow rate or maximum potential
concentration determined), questions the commenter, at a minimum, the span, range and maximum
potential flow rate/concentration provisions of 40 CFR part 75, Appendix A should be allowed, and it
may be prudent to abandon the details contained in section 3.2.3.3 and simply refer to the associated 40
CFR part 75 provisions.

Response to Comment 24: The EPA agrees with the commenter's recommendation to dispense with the
details in section 3.2.3. The final rule simply requires all of the additional monitoring systems needed to
convert Hg concentrations to the units of the standards to meet the requirements of 40 CFR part 75. This
approach is appropriate, since ECMPS will be used to receive and process the CEMS data that are used
to assess compliance with the Hg emission limits under subpart UUUUU.

Comment 25: Commenter 17881 states that the cycle time test provisions of part 75, Appendix A,
section 6.4 allow a change of < 6% of the average reading over a 6-minute period to define a stable
reading when conducting the cycle time test and that this provision should also be allowed in section
4.1.1.4 of Appendix A.

Response to Comment 25: In the final rule, the additional text suggested by the commenter has been
added to the cycle time test procedure in section 4.1.1.4 of Appendix A.

Comment 26: Commenter 18449 states that span ranges will be difficult since pollutants are not
expected to vary over a wide concentration (during normal operation as compared to startup).

Commenter 18449 suggests the EPA update the span wording in PS-12A and Appendix A, where it
allows 10 ug and multiples of 10 ug; commenter 18449 states that multiples of 10 ug doesn't work for
very low Hg values as in Utility MACT, where a span range of 5 ug/m3 might be more appropriate.
Commenter 18449 states that each defined span range requires a set of two different gases (Hg- and
Hg2+), each at three different concentrations (20-30 percent, 50-60 percent, and 80-100 percent of
span), which is a problem for both suppliers and NIST, and suggests the number of spans be minimized.

138


-------
Commenter 18449 states that utility MACT spans should be fixed at 5, 10, 20, and 40 ug/m3.
(Commenter 18449 states that Cement MACT spans should not be available in increments of 10 ug but
should be spaced much farther apart, such as 100, 180, 260, etc. Commenter 18449 states the wording
should be clarified so that users can choose such ranges, rather than forced to nearest multiple of 10.)

Commenter 18449 states that CAMR also required Hg calibration gases be traceable to NIST, however,
NIST at that time had no idea how to certify Hg generators or calibration gases and had to develop the
methodology, procedure, and processes, with no protocols in place until well after the start of the
program, so that the EPA was forced to defer the NIST traceability requirement for a year. Commenter
18449 notes that the EPA and NIST still have a number of current issues, for which NIST will require
external funding, and identified these issues as follows:

1.	Measure and certify lower level elemental concentrations. According to the commenter, currently
NIST can only certify concentrations down to 0.5 (J,g/m3, and this value has a very high uncertainty of
6.1 percent (Prob_95 percent). The commenter states that NIST will have to be able to certify points at
20-30 percent of the lowest span value that the EPA envisions; for example, a 0.25 |ig/m3 certified
concentration would be needed for lower span ranges.

2.	Measure and certify high elemental concentrations (100 to 260 (j,g/m3). The commenter states that this
is required for the Cement MACT rather than this rule, but it's included here since it has to be done.

3.	Measure mercury chloride generators. According to the commenter, currently there is a 9 percent
discrepancy between NIST traceable elemental calibrators and NIST traceable ionic evaporative
calibrators, and the reason for this is unknown. The commenter states that if NIST could accurately
measure the output of evaporative calibrators, this difference could be explained. According to the
commenter, the current Interim Oxidized Protocol deems a generator to be certified if all inputs are
NIST traceable. The commenter states that this approach can remain, but the ability of NIST to confirm
the output of even a single test ionic generator would increase confidence that the various types of
generators all yield identical output concentrations.

4.	Improve "routine" elemental certifications. The commenter states that certifications of elemental
calibrators by NIST over the range 0.5 to 38 [j,g/m3 have been "routine" for several years, but it recently
took three separate attempts with NIST and over one year for the commenter to have a pair of calibrators
correctly certified over this range. The commenter states that the high levels were correct, but the low
concentrations were off by up to 12 percent, and if legislation been in place, this delay would have
caused enormous problems.

5.	The EPA Interim Traceability Protocols currently state: "For CEMS applications, this protocol applies
only to Hg monitoring system span values greater than or equal to 5.0 micrograms per cubic meter
([j,g/m3)" According to the commenter, this must be changed if the EPA envisions span values of less
than 5 [j,g/m3 will be required under the new legislation. The commenter states that rovided that NIST
can provide lower uncertainties for lower concentrations for elemental generators, the commenter does
not see any reason why the interim protocols will not work at the lower concentrations needed for a 2
[j,g/m3 span range.

6.	Vapor pressure of mercury. The commenter states that there is a 7 - 9 percent difference between two
proposed mercury vapor equations. According to the commenter, these equations are used to predict the
output concentration of saturated vapor elemental mercury generators running at a specific temperature;
one equation has been in use for decades and been experimentally verified on an ongoing basis, even by

139


-------
the NIST Gas Metrology Group, and the other, recently proposed by another group within NIST
(Boulder Colorado) predicts a mercury concentration in saturated vapor 7 to 9 percent higher but as
viewed as "theoretically correct". The commenter states that although the EPA's Interim Elemental
Mercury Traceability Protocol neatly sidesteps this issue, it has worldwide implications for the accuracy
of all measurements of mercury in air or other gases.

Response to Comment 26: The EPA disagrees that fixed span values should be specified in PS-12A or
Appendix A; however, in the final rule, the EPA has revised Appendix A, which includes the Hg
monitoring requirements specific to this rule, to enable greater flexibility when identifying an
appropriate span value. The Appendix A requirements provide for identifying a potential span value
(based on a level two times the Hg concentration equivalent to the emission limit), but also provides
options for rounding the span value to either the next highest integer, the next highest multiple of 5, or
the next highest multiple of 10. In regard to Item 1, the EPA disagrees that NIST will have to be able to
certify elemental Hg concentrations less than 0.5 |ig/m3 at this time. No span values (i.e., a span value
less than 5 |ig/m3) that would require certified elemental Hg concentrations less than 0.5 |ig/m3 are
required by the final rule. The EPA does, however, encourage the development and use of lower span
ranges (that meet Appendix A), where appropriate. If a span value is chosen that requires the use of
certified elemental Hg concentrations less than 0.5 |ig/m3, NIST would be capable of conducting
certifications at this level, though as far as the EPA is aware NIST has not yet conducted certifications at
these low levels. Regarding Item 2, the EPA agrees that higher level elemental Hg calibration gas
concentrations are needed for potential future regulatory requirements independent of this rule. The EPA
has worked with NIST to expand the range of NIST elemental Hg reference concentrations that can be
certified and certified elemental Hg concentrations ranging from 0.5 |ig/m3 to 300 |ig/m3 are now
available. Concerning Item 3, the EPA agrees that NIST possessing an ability to accurately measure the
output of evaporative mercuric chloride generators is desired; however, in the absence of this capability,
the current Interim Traceability Protocol for certifying oxidized Hg gas generators is accepted as the
appropriate methodology for establishing NIST traceability for mercuric chloride. Moreover, this
approach reflects significant effort on the part of the EPA, the CEMS vendor community, and affected
sources to examine the calibration generator traceability issues, and devise an agreed upon approach for
addressing those issues. For Item 4, it is the EPA's understanding that NIST currently performs
elemental Hg gas generator certifications on a routine basis and the EPA is unaware of any problems in
this regard. The EPA disagrees with the assertion in Item 5 that the EPA must revise the Interim
Traceability Protocol; span values less than 5 |ig/m3 are not required by this rule and as a result, changes
to the Interim Traceability Protocols are not necessary for implementation of the rule. The EPA does
agree with the commenter that the EPA Interim Traceability Protocols are suitable for lower elemental
Hg concentrations such as those associated with a 2 |ig/m3 span range. In fact, NIST and at least one
vendor are capable of certifying elemental Hg generators at concentrations as low as 0.5 |ig/m\ so the
EPA will consider modifying the protocol at a later time. Finally, regarding Item 6, while the EPA is
aware that there is a 7 to 9% difference between two Hg vapor equations used by the scientific
community, the EPA's application of NIST traceability for elemental Hg is empirically based upon an
unbroken chain of comparisons anchored to an accepted, NIST elemental reference gas which is
independent of these theoretical Hg vapor equations.

140


-------
5A07a - Testing/Monitoring: Application of PM CEMS

Commenters: 17197, 17383, 17402, 17621, 17623, 17638, 17655, 17675, 17677, 17681, 17689, 17696,
17702, 17704, 17705, 17711, 17714, 17716, 17725, 17728, 17729, 17730, 17737, 17740, 17747, 17752,
17754, 17756, 17758, 17761, 17774, 17775, 17790, 17795, 17796, 17798, 17800, 17801, 17808, 17812,
17813, 17818, 17820, 17821, 17868, 17871, 17881, 17886, 17912, 17913, 17914, 17975, 18014, 18428,
18443, 18447, 18498, 18831, 18935, 18963, 19033, 19114, 19120, 19121, 19536, 19537, 19538, 18023

1.	Support of use of PM CEMS during startup and shutdown.

Comment 1: Commenter 17975 supports the proposed requirement to use PM CEMS on EGUs that
elect to comply with the PM filterable limit as a surrogate for non-Hg metals because PM CEMS are an
EPA approved monitoring method, and in use at an increasing number of plants. The commenter
believes that the EPA needs to make the final rule clear that PM CEMS must be operated around the
clock, including during startup, shutdown, maintenance, and malfunctions, when PM emissions may be
at their peak. The commenter refers to an "expert's" conversations with several PM CEMS vendors that
indicate these monitors can be calibrated to accurately measure PM at very high concentrations that
occur during startup and shutdown.

Response to Comment 1: The final rule clarifies that the operating limit monitoring for the PM and
HAP metals emission limits requires use of a PM CPMS, not PM CEMS, and work practice standards
that include operation of monitoring, not numerical emissions limits, during periods of startup or
shutdown. The final rule also does provide for the use of a PM CEMS to determine compliance with the
filterable PM emission limit if the source elects to use this approach (see the final preamble for further
discussion).

2.	Recommendations to use PM CEMS as indicator/CAM.

Comment 2: Multiple commenters (17705, 17725, 17716, 17820, 17886, 18014, 18498) suggest that
the final rule use PM CEMS data as an indicator of PM control performance, but not to enforce a
numeric PM limit, and that alternatively, sources could also demonstrate a reasonable assurance of
compliance based on opacity or parametric monitoring as the EPA has already proposed under other
rules.

Comment 3: Several commenters (17623, 17638, 17681, 17676, 17775, 17886) suggest using PM
CEMS within a MACT monitoring program modeled after the part 64 CAM program.

Comment 4: Several commenters (17402, 17716, 17737, 17775, 17886) believe current PM CEMS
technology is useful as a compliance assurance monitoring tool that can trigger requirements for
investigation and corrective action.

Comment 5: Several commenters (17402, 17681, 17716, 17737, 17775) note successful implementation
the CAM rule under 40 CFR part 64 and request that the final rule adopt this approach for continuous
monitoring. Commenter 17402 suggests that CAM plans could include opacity monitoring, a site-
specific utility MACT compliance plan, and periodic stack testing.

Response to Comments 2-5: The final rule requires the use of a PM CPMS for an operational limit
and does not enforce a numeric PM limit when this monitoring approach is used. In the final rule
facilities would be allowed to petition the Administrator under section 63.8(f) of subpart A of part 63 for

141


-------
an alternative to use opacity or parametric monitoring at a specific site in lieu of required monitoring in
the final rule. The final rule also does provide for the use of a PM CEMS to determine compliance with
the filterable PM emission limit if the source elects to use this approach (see the final preamble for
further discussion).

3. Requests for clarification on establishment of PM CEMS operating limits.

Comment 6: Commenter 17729 requests clarification that the rule requires using the filterable PM
measurement to set an ongoing 30-day rolling average operational limit with compliance based on a
filterable PM CEMS.

Response to Comment 6: The final rule requires the use of a PM CPMS for an operational limit and
does not enforce a numeric PM limit. The PM CPMS is required to report measurements in raw data
output from the monitor and not a correlation to manual filterable PM measurements. The final rule also
does provide for the use of a PM CEMS to determine compliance with the filterable PM emission limit
if the source elects to use this approach (see the final preamble for further discussion).

Comment 7: Commenter 17881 states that it is not clear if section 63.10011(b)(3) applies to units with
PM CEMS. Commenter notes that for a unit complying via the use of PM CEMS, it is not clear if"non-
Hg HAP metals" refers to the aggregate of all regulated HAP metals or each of the individual HAP
metals. According to the commenter, it seems like this provision must be based on all metals in
aggregate, or it would be impractical to implement.

Response to Comment 7: The final rule requires the use of a PM CPMS for an operational limit and
does not enforce a numeric PM limit. The final rule also does provide for the use of a PM CEMS to
determine compliance with the filterable PM emission limit if the source elects to use this approach (see
the final preamble for further discussion). The source has the option to measure non-Hg HAP metals
with a reference method each quarter. The monitoring and testing that is required will depend on which
emission limit the source elects.

Comment 8: Several commenters (17730, 17868, 18023) state that proposed reliance on total PM as a
surrogate for the non-Hg HAP metals, and the use of the PM CEMS to conduct performance testing and
measure ongoing compliance is poorly defined. Commenters (17800, 18023) state that the provisions in
Table 4 ("highest 1-hour average") are inconsistent with the provisions in proposed section 63.10011(d)
for determining the filterable PM operating limit. According to commenter 17730, the proposal requires
that when sources conduct the initial performance test, they must develop a filterable PM emission limit
based on a compliant stack test using Method 5 and Method 202, but the proposal fails to provide any
further explanation of how sources are supposed to derive the filterable PM limit, or whether or not
sources are also required to comply with the individual HAP metals emission standards. The commenter
believes that there are several calculations that could be used to determine a filterable PM limit based on
stack test results but that the exact calculation is not specified in the proposal. The commenter
characterizes this portion of the proposal as "essentially establishing a surrogate for measuring a
surrogate" and "simply nonsensical." The commenter believes it is unreasonable for the EPA to seek
comment on such a poorly defined proposal, and the commenter believes that if the agency continues to
pursue the total PM standard as a surrogate for non-Hg HAP metals, the agency should make clear the
methodology for establishing the filterable PM limit and re-propose the rule for public comment because
the commenter cannot effectively provide comment without further definition.

142


-------
Response to Comment 8: We are no longer requiring use of a PM CEMS for a PM limit. We are
requiring the use of a PM CPMS for an established operational limit. The source has the option to
measure non-Hg HAP metals with a reference method each quarter. The final rule also does provide for
the use of a PM CEMS to determine compliance with the filterable PM emission limit if the source
elects to use this approach (see the final preamble for further discussion).

Comment 9: Several commenters (17754, 17800,18963, 18023) state that the owner/operator must
"[mjaintain the PM concentration (mg/dscm) at or below the highest 1-hour average measured during
the most recent performance test demonstrating compliance with the total PM emissions limitation,",
and that proposed section 63.10011 directs that the operating limit for PM should be based on the
average of the PM filterable results of the three Method 5 performance test runs, whereas Table 4
provides that the PM limit shall be the highest 1-hour average measured during the most recent
performance test. According to the commenters, these two relevant provisions appear to reflect
inconsistent analyses and compliance demonstration periods and therefore should be clarified in order to
avoid potential confusion, misinterpretation, and/or inconsistent application. The commenters request
that the proposed rule be clarified to expressly provide that the operating limit for demonstrating
continuous compliance with the emission standard for total PM shall be based on the highest 1-
hour average measured during the most recent performance test, in accordance with Table 4 of the
proposed rule. The commenters state that consistent with this approach, if the total PM emissions from
an affected EGU exceed the previously-established operating limit during any period, the
owner/operator of such unit would have the option of conducting another performance test, and the
highest average value measured during such test would become the new applicable operating limit for
the relevant unit.

Response to Comment 9: Under the final rule, you may elect to comply with an optional operating
limit for PM. If you use this method to demonstrate continuous compliance, you must install a PM
CPMS and establish the operating limit during the initial compliance test for filterable PM, total non-
mercury HAP metals, or individual non-mercury HAP metals (or HAP metals inclusive of mercury for
liquid oil-fired units). The operating limit for demonstrating continuous shall be based on the highest 1-
hour average measured during the most recent performance test. If you use a PM CPMS and associated
operating limit, you must conduct the applicable Method 5 or Method 29 test once annually and re-
establish the operating limit during each performance test. A PM CPMS does not need to meet the
requirements for a PM CEMS under PS 11. The final rule also does provide for the use of a PM CEMS
to determine compliance with the filterable PM emission limit if the source elects to use this approach
(see the final preamble for further discussion).

Comment 10: Commenter 17871 states that the EPA has failed to demonstrate that a functional
relationship between filterable particulates and condensable particulates in EGUs. According to the
commenter, this approach becomes unworkable when one considers the rule requires annual testing
resulting in new standard for non-Hg metallic HAP every year. The commenter notes that under the
proposed rule, the use of SO2 as a surrogate for acid gas HAP is appropriate because the EPA has
correctly noted that "the technologies used for removal of acid gases are primarily those that are also
used for FGD" (76 FR 25023). The commenter states that SO2 would be measured with a CEMS
certified and operated in accordance with part 75. According to the commenter, even though proven
technology and quality assured emission data is used to demonstrate compliance with the standard, a
"second MACT standard" has been created that requires that the sorbent injection rate be maintained at
or above the lowest 1-hour average sorbent flow rate measured during the most recent performance test.
Commenters 17871 and 17740 state that by setting up compliance in this manner, the emission standard
becomes the basis for an operating limit, which in turn becomes another, far more stringent, standard of

143


-------
compliance that a facility would be required to meet on a continuous basis. According to the
commenters, this is inconsistent with the purpose of an emission standard, which allows for fluctuations
in emissions over a 30-day period and improperly imposes two MACT standards on sources.

Response to Comment 10: The comments are inapplicable, as the final rule no longer contains a
condensable PM emissions limit and, for those source owners or operators who choose to use SO2
CEMS, no operating limit exists and no parameter monitoring is required.

Comment 11: Commenter 17623 states that the total PM standard is unclear and impracticable because
it will be difficult for sources to plan for changes to the limits resulting from performance testing.
According to the commenter, the PM limit of 0.030 lb/MMBtu for existing sources would be adjusted
downward based on the PM emission rate measured by the reference method during each periodic
performance test. The commenter believes that there are two possible interpretations of the proposed
rule that would result in this downward adjustment.

1.	According to the commenter, one interpretation would require the PM limit to be adjusted down
based on the proportion of Total PM emissions that are condensable. The commenter states that if,
for example, 50 percent of the total PM emissions are condensable at a particular unit, then the
applicable PM CEMS limit for that unit would be reduced to 0.015 lb/MMBtu.

2.	According to the commenter, the other interpretation would require the PM limit to be set at the
actual filterable PM emissions rate measured during the initial and subsequent PM performance tests
conducted for the unit. The commenter states that under either approach, the conversion of the total
PM numeric rate limit into a filterable PM standard that a PM CEMS can monitor will require
sources to readjust their compliance level after each performance test.

Response to Comment 11: Under the final rule, you may elect to comply with an optional operating
limit for PM. If you use this method to demonstrate continuous compliance, you must install a PM
CPMS and establish the operating limit during the initial compliance test for filterable PM, total non-
mercury HAP metals, or individual non-mercury HAP metals (or HAP metals inclusive of mercury for
liquid oil-fired units). The operating limit for demonstrating continuous shall be based on the highest 1-
hour average measured during the most recent performance test. If you use a PM CPMS and associated
operating limit, you must conduct the applicable Method 5 or Method 29 test once annually and re-
establish the operating limit during each performance test. A PM CPMS does not need to meet the
requirements for a PM CEMS under PS 11. The final rule also does provide for the use of a PM CEMS
to determine compliance with the filterable PM emission limit if the source elects to use this approach
(see the final preamble for further discussion).

Comment 12: Commenter 17795 states that there is conflicting language in the proposal. According to
the commenter, pages 25029-25030 indicate that ESP and fabric filter parameter monitoring is required
for all units not using HC1 CEMS, but the language from page 25031 states that parameter monitoring is
required only if units are not using PM CEMS. According to the commenter, fabric filter BLDS and ESP
voltage limit monitoring requirements should apply only to units that do not use PM CEMS as stated on
page 25031. The commenter believes this was the EPA's intent, as there is no justification or further
assurance of compliance for the monitoring of particulate control equipment operational parameters
when direct continuous monitoring of filterable PM is implemented. According to the commenter, the
EPA should clarify that it did not intend to make ESP voltage and fabric filter BLDS readings an
operational limit if a unit uses a PM CEMS to demonstrate compliance.

144


-------
Response to Comment 12: Control equipment parameters are not monitored under the final rule, so this
concern is moot.

4. Concerns with using PM CEMS data to determine compliance with non-Hg metals standard.

Comment 13: Commenter 17621 states that the merits of including condensable PM in the total PM
limit are difficult to evaluate, as no test data are available for the exact condensable PM method that is
required for compliance with the proposed MACT limits. The commenter states that the ICR required
condensable PM to be measured using OTM-28, which method was changed significantly before it was
promulgated in 2010 as revised Method 202. According to the commenter, most ICR test contractors
used OTM-28, a few used the original Method 202, and because none of the ICR tests used revised
Method 202, the conclusions of EPRI's evaluation of condensable PM method usefulness are uncertain.
According to the commenter, adding a condensable PM measurement to the filterable PM sampling train
increases the total variability and reduces the sensitivity of the combined measurement system. The
commenter states that a recent field study conducted by American Electric Power (AEP) and EPRI
found that Method 202 (condensable PM) had much higher variability than Method 5 (filterable PM) for
replicate test runs (EPRI, 2011) and that in the ICR Part III tests at coal-fired EGUs, the relative
standard deviations (RSDs) of condensable PM test series averaged slightly higher than the RSDs of
filterable PM test series (24 percent compared to 20 percent). According to the commenter, the detection
limit of a combined Method 5/Method 202 sampling train is twice as high as that of a Method 5 train
alone, as each gravimetric measurement adds uncertainty to the total.

Moreover, according to the commenter, the accuracy of the new Method 202 has not been demonstrated
adequately and requires additional research. The commenter states that laboratory studies conducted by
EPRI pointed to a potential negative bias in OTM-28, which did not effectively capture S03 (EPRI,
2009)., and that only about half of the SO3 introduced into the sampling train was captured. According
to the commenter, this finding indicates that Method 202 may not be accurate under flue gas conditions
that are expected to be increasingly prevalent in power plants as wet FGD systems (which tend to
produce SO3) are added.

The commenter states that a total PM limit is problematic for compliance monitoring, as continuous PM
monitors measure only filterable PM. According to the commenter, since condensable PM emissions are
a product of the coal sulfur content and other factors (e.g., ash properties, SCR SO2 oxidation rate), it is
not clear how a power plant would determine compliance with the total PM limit without being able to
monitor both filterable PM and condensable PM on a continuous basis. The commenter asserts that the
difficulty of demonstrating and achieving compliance with total PM limits will depend on the percentage
of total PM that is condensable PM and how variable the ratio of filterable PM to condensable PM is
over time. Commenter states that (in document; Figure 2-2 is histogram of condensable PM as a
percentage of total PM: Part III ICR Coal-fired EGUs) the fraction of total PM that is condensable PM
varies from under 1 percent to over 99 percent across the coal-fired EGUs tested in the ICR. According
to the commenter, the ICR database does not contain sufficient historical condensable PM data to
determine how much condensable PM emissions will change at a unit over time.

Finally, the commenter states that EPRI's study has implications for how representative the ICR data are
of industry emissions, as well as for future performance testing. The commenter states that the EPA
based the MACT floor for total PM on the lowest test series for each EGU, regardless of the method
used to measure filterable PM (Method 5, Method 29, or OTM-27). According to the commenter, as
many of the lowest ICR emissions are from Method 29 tests run at 320 °F, those results will not be
representative of tests made using Method 5 at 250 °F, and as a result, there is considerable uncertainty

145


-------
regarding the true emissions of filterable PM from the power industry. The commenter states that the
compliance method for filterable PM specified in the proposed rule is Method 5, while the ICR test data
include filterable PM results from Methods 5, 29, and OTM-27. According to the commenter, to
eliminate the various method biases identified in the EPRI/AEP study, the requirement to run Method 5
tests at 320 °F should also apply to Method 29 metals tests, and there should be a requirement to use
nonreactive filters.

Comment 14: Commenter 18429 states that the unit-by-unit, single test approach in setting a MACT
limit proposed by the EPA is inappropriate. The commenter notes that an example of the difficulty in
meeting a PM operational limit is one of the commenter's units equipped with a wet scrubber, SCR, and
ESP for emissions controls. According to the commenter, when following the stack test that would
establish the filterable PM operational limit, the unit's PM CEMS consistently recorded 30-day averages
above that level, because the initial filterable PM level was measured while the boiler was operating in a
steady-state, full load condition over a brief period of only hours, and the PM CEMS then measures
filterable PM levels continuously during all load and operating conditions. According to the commenter,
the EPA's proposed approach punishes good behavior and is a setup for failure. The commenter
encourages the EPA to replace a total PM with a category-wide, filterable PM limit that is achievable
under the variety of conditions that utility units experience. The commenter further notes the comments
submitted by EPRI in this docket provide detailed analysis justifying the use of filterable PM as an
adequate surrogate for all non-Hg metals. The commenter states that among the key conclusions are that
filterable PM is correlated to emissions of particulate-phase metals (e.g., chromium) and there is a
statistically significant correlation with metals that are volatile at stack gas temperature, particularly Hg
and selenium.

Comment 15: Commenter 17197 believes the proposed PM CEMS operating limit determination
method is unworkable, arbitrary, likely overly restrictive, and non-representative. The commenter
believes the better solution is replacing the proposed total PM limit with a filterable-only PM limit for
non-Hg HAP metals using PM CEMS, however the commenter offers an alternative. Commenter
recommends instead that the surrogate PM CEMS operating limit (filterable PM) be established by using
the simultaneous EPA Method 5 and Method 202 stack testing results to establish the EGU's filterable-
to-total PM ratio. According to the commenter, the PM CEMS operating limit (filterable PM) would be
appropriately set by adjusting the total PM limits (0.030 lb/MMBtu or 0.30 lb/MWh) using the
filterable-to-total PM percentage established during the three 1-hour test run performance testing. The
commenter states that for example, if the measured filterable-to-total PM factor was 0.5, the PM CEMS
operating limits (filterable PM) would be set at 50 percent of the total PM Limits (0.015 lb/MMBtu or
0.15 lb/MWh). According to the commenter, setting the PM CEMS operating limit using this alternate
methodology is more representative because it utilizes all three performance test runs and not just the
highest 1-hour average measured EPA Method 5 rate. The commenter asserts that this methodology is
less dependent on short-term PM control system performance, since it is based on the established
filterable-to-total PM ratio, and is less arbitrary since the resulting PM CEMS operating limits have
some equivalence to the underlying total PM limit.

Comment 16: Several commenters (17623, 17677, 17681, 17730, 17775, 18023) believe that it is
problematic to use PM CEMS data to determine compliance with a total PM limit because PM CEMS
only measure filterable particulate. Commenters (17623, 17775) states that the technology used to
establish the total PM limit and to perform periodic stack tests that re-set the "floating" PM CEMS
operating limit use significantly different technology. Commenter 17775 states that the proposal does
not indicate that the agency considered how the permissible PS-11 measurement error might impact
compliance determinations. Commenter 17677 is concerned that the PM CEMS operating limit appears

146


-------
to be an enforceable requirement treated as equivalent to the total PM limit despite the fact that the PM
CEMS limit reflects only a fraction of the total non-Hg metals being emitted during the performance
test. Commenter 17677 believes that setting an enforceable limit on a surrogate seems refutable during
enforcement proceedings. Several commenters (17623, 17677, 17681) suggest requiring another stack
test for total PM within 60 days of exceeding the PM CEMS operating limit rather than deeming the
source out of compliance with the HAP emissions limit. Commenters (17676, 18023) believe that annual
compliance tests are sufficient to ensure compliance.

Comment 17: Several commenters (17689, 17704, 17813, 18014) state that the proposed PM total
approach is unworkable for several reasons. According to the commenters, Methods 5 and 202 would be
utilized to determine the condensable and filterable portions of PM total, with PM CEMS measurements
used to set unit operating limits afterwards, but Method 5 does not and cannot account for variations in
PM filterable actual levels over a range of unit operating levels, including startup and shutdown, that a
PM CEMS would measure, so, in effect, Method 5 measurements when compared to PM CEMS
measurements over full unit operating conditions is not appropriate. Several commenters (17689, 17702,
17704, 17813) state that the PM standard should be based on a PM filterable limit only.

Comment 18: Commenter 17737 states that PM CEMS provide an indirect measure by "correlating" the
monitor's response to short term stack tests (e.g., Method 5 tests) conducted over a range of
concentrations that must be sufficient to include the level of the applicable emission standard.
Commenter provides an analysis by UARG that indicates that a PM CEMS meeting the criteria in PS 11
can produce responses that differ significantly (on the order of 25 percent) from what would be obtained
with Method 5. (See, e.g., UARG Comments, EPA-HQ-OAR-2002-0058-2880 at 51-54; EPA-HQ-
OAR- 2005-0031-0246, at 3-10). According to the commenter, for example, if the filterable PM limit is
set at 0.030 lb/MMBtu and the Method 5 test result is 0.028 lb/MMBtu, emissions would be compliant
with the filterable PM limit, but with the allowed measurement error of 25%, the PM CEMS could
present a PM level of 0.035 lb/MMBtu and thus demonstrated false exceedance of the PM limit where
the true PM level should have be in compliance.

Response to Comments 13 - 18: The final rule no longer requires monitoring with a PM CEMS. Under
the final rule, you may elect to comply with an optional operating limit for PM. If you use this method to
demonstrate continuous compliance, you must install a PM CPMS and establish the operating limit
during the initial compliance test for filterable PM, total non-Hg HAP metals, or individual non-Hg
HAP metals (or HAP metals inclusive of Hg for liquid oil-fired units). The operating limit for
demonstrating continuous shall be based on the highest 1-hour average measured during the most recent
performance test. If you use a PM CPMS and associated operating limit, you must conduct the
applicable Method 5 or Method 29 test once annually and re-establish the operating limit during each
performance test. A PM CPMS does not need to meet the requirements for a PM CEMS under PS 11.
The final rule also does provide for the use of a PM CEMS to determine compliance with the filterable
PM emission limit if the source elects to use this approach (see the final preamble for further
discussion).

Comment 19: Commenter 17737 states that they conduct Method 5 performance tests each year, and
the results of those tests have varied as much as 80 percent for a given unit. According to the
commenter, the EPA provides no data or explanation as to how this operating limit might address this
variability in operating conditions that are certain to occur. According to the commenter, this is likely
because the three-run average of a stack test conducted during 1 day at constant operating conditions,
essentially represents a single point measurement, which by its very nature cannot provide any
indication of variability. Several commenters (17737, 17790, 18014) state that use of the EPA's

147


-------
proposed method of setting the operating limit would leave compliance with that limit completely to
chance (i.e., dependant on the performance test results), and utilities would not know what their
operating limit was until compliance with that standard was in effect, leaving no opportunity to prepare
for the standard. The commenters note that the EPA must modify its standard to allow units to comply.

Response to Comment 19: Under the final rule sources are allowed to establish different operating
limits monitored with a PM CPMS if they believe there is variability due to varying load conditions. The
final rule no longer requires monitoring with a PM CEMS. The final rule also does provide for the use of
a PM CEMS to determine compliance with the filterable PM emission limit if the source elects to use
this approach (see the final preamble for further discussion).

Comment 20: Commenter 17711 states that PM CEMS measure only filterable PM yet the EPA
proposes that the operating limit for facilities using PM CEMS is the highest 1-hour average
concentration in mg/dscm measured during the most recent performance test. According to the
commenter, the EPA is setting an artificially low PM standard for units using PM CEMS. The
commenter states that the compliance method should match the standard; the EPA should either set
filterable PM emission limits or establish more appropriate operating limits for sources using PM CEMS
(e.g., the total PM limit minus the amount of condensable PM measured during the last performance
test).

Response to Comment 20: Under the final rule, you may elect to comply with an optional operating
limit for PM. If you use this method to demonstrate continuous compliance, you must install a PM
CPMS and establish the operating limit during the initial compliance test for filterable PM, total non-Hg
HAP metals, or individual non-Hg HAP metals (or HAP metals inclusive of Hg for liquid oil-fired
units). The operating limit for demonstrating continuous shall be based on the highest 1-hour average
measured during the most recent performance test. If you use a PM CPMS and associated operating
limit, you must conduct the applicable Method 5 or Method 29 test once annually and re-establish the
operating limit during each performance test. A PM CPMS does not need to meet the requirements for a
PM CEMS under PS 11. The final rule also does provide for the use of a PM CEMS to determine
compliance with the filterable PM emission limit if the source elects to use this approach (see the final
preamble for further discussion).

Comment 21: Commenter 19120 states that the establishment of an operating limit makes the 0.030
lb/MMBtu limit on total PM arbitrary. According to the commenter, for example, if the emissions rate
during stack testing for total PM is well below 0.030, exceedance of the filterable PM operating limit
would not be an indication that the actual emissions limit of 0.030 lb/MMBtu was exceeded or even
approached. The commenter recommends that the EPA base the operating limit on a more representative
value than simply basing it on the value achieved during the stack test and notes that while section
63.10011(d) indicates that the operating limit will be based on the average of the PM filterable results of
the three Method 5 performance test results, Table 4 indicates that the operating limit will be based on
the highest 1-hr average measured during the test.

Response to Comment 21: Under the final rule, you may elect to comply with an optional operating
limit for PM. If you use this method to demonstrate continuous compliance, you must install a PM
CPMS and establish the operating limit during the initial compliance test for filterable PM, total non-Hg
HAP metals, or individual non-Hg HAP metals (or HAP metals inclusive of Hg for liquid oil-fired
units). Under the final rule sources are allowed to establish different operating limits monitored with a
PM CPMS if they believe there is variability due to varying load conditions. The final rule no longer
requires monitoring with a PM CEMS. The final rule also does provide for the use of a PM CEMS to

148


-------
determine compliance with the filterable PM emission limit if the source elects to use this approach (see
the final preamble for further discussion).

Comment 22: Several commenters (17402, 17775, 17790) support use of PM as a surrogate for non-Hg
HAP metals. Other commenters (17402, 17675, 17716) request that the agency not require regulated
units to install and use PM CEMS as the continuous compliance determination method. Several
commenters (17402, 17716, 17775) support inclusion of PM CEMS as one option among others for an
appropriate filterable PM limit, provided the EPA has considered and addressed all of the issues
associated with use of PM CEMS for that purpose. Commenter 17402 states that including PM CEMS
as an option would be consistent with recent revisions to NSPS Subpart Da. However, the following
commenters do not believe that the proposal accounts for the following issues relevant to the use of PM
CEMS as a direct indicator of compliance following periodic performance tests:

1.	Multiple commenters (17402, 17675, 17681, 17696, 17716, 17728, 17737, 17752, 17775, 17790,
17868, 18023) note the inaccuracy of PM CEMS at low concentrations;

2.	Multiple commenters (17402, 17716, 17728, 17737, 17752, 17775, 17790, 17868, 17886, 18014,
18023) state there is a lack of data correlating PM CEMS response with actual emissions during
startup and shutdown and across load ranges. Commenters (17775, 17737) state that the proposal's
explanations (that the proposed limits were achievable during periods of startup and shutdown based
on use of a 30-day averaging period and assumptions regarding the use of cleaner fuels) were not
substantiated with data;

3.	Multiple commenters (17402, 17675, 17681, 17696, 17716, 17728, 17775, 17868, 18023) are
concerned about the PM CEMS allowed measurement error (i.e., high degree of uncertainty within
PS-11 tolerance interval);

4.	Multiple commenters (17402, 17716, 17728, 17737, 17752, 17775, 18023) note the differences in
measurement methods or conditions that can affect monitor calibration;

5.	Multiple commenters (17402, 17675, 17681, 17696, 17716, 17728, 17775, 17790, 17868, 18023)
question the achievability of PS 11 performance criteria at the low emission limits proposed. In
particular, commenter 17775 provides an analysis by a consultant that indicates the PM CEMS are
not a viable compliance option and alleges that proposed PM limits are so low that existing PM
CEMS technologies cannot pass PS-11 criteria;

6.	Commenters 17737 and 17775 claim there is a lack of compliance provisions allowing the
operational flexibility necessary to develop strong PM CEMS correlations to the reference method

7.	Several commenters (17696, 17737, 17752, 17775, 18023) question the long-term reliability ofPM
CEMS and long-term stability of measurement responses of current PM CEMS technologies

8.	Commenter 17868 notes the lack of alternate limits for PM, SO2, HC1, and Hg during periods of PS-
11 testing;

9.	Commenter 18023 states there is a lack of NIST traceable PM daily calibration standards:

10.	Commenters 18023 and 17790 state the use of PM CEMS is cumbersome, expensive, and includes
highly variable calibration procedures.

Response to Comment 22: PM CEMS are no longer required under the final rule. You may elect to
comply with an optional operating limit for PM. If you use this method to demonstrate continuous
compliance, you must install a PM CPMS and establish the operating limit during the initial compliance
test for filterable PM, total non-Hg HAP metals, or individual non-Hg HAP metals (or HAP metals
inclusive of Hg for liquid oil-fired units). The operating limit for demonstrating continuous shall be
based on the highest 1-hour average measured during the most recent performance test. If you use a PM
CPMS and associated operating limit, you must conduct the applicable Method 5 or Method 29 test once
annually and re-establish the operating limit during each performance test. A PM CPMS does not need

149


-------
to meet the requirements for a PM CEMS under PS 11. The final rule also does provide for the use of a
PM CEMS to determine compliance with the filterable PM emission limit if the source elects to use this
approach (see the final preamble for further discussion).

Comment 23: Commenter 17737 states that the EPA should establish a separate standard for periods of
startup and shutdown. According to the commenter, however, if the EPA promulgates a rule that
requires use of PM CEMS as a compliance method during periods of startup and shutdown, the EPA
cannot simply assume that averaging time or differences in fuel will compensate for these period.

Response to Comment 23: The comment is moot, as the rule no longer has emissions limits applicable
during periods of startup or shutdown.

Comment 24: Commenter 17800 states that the EPA should revise the compliance procedures for the
non-Hg metals standard. Commenter believes that the EPA's proposed compliance procedures for the
total PM standard are not workable because the EPA does not clearly describe how compliance would
be determined or how the proposed site-specific limit would be established or how the limit would
apply. Commenter is opposed to a site-specific limit. The commenter states that a PM standard should
apply consistently for all affected sources and compliance must be established that accurately represents
the actual emissions from the source and test methods should be clarified and not combine different
testing and measurement components.

Response to Comment 24: PM CEMS are no longer required under the final rule. You may elect to
comply with an optional operating limit for PM. If you use this method to demonstrate continuous
compliance, you must install a PM CPMS and establish the operating limit during the initial compliance
test for filterable PM, total non-Hg HAP metals, or individual non-Hg HAP metals (or HAP metals
inclusive of Hg for liquid oil-fired units). The operating limit for demonstrating continuous shall be
based on the highest 1-hour average measured during the most recent performance test. If you use a PM
CPMS and associated operating limit, you must conduct the applicable Method 5 or Method 29 test once
annually and re-establish the operating limit during each performance test. A PM CPMS does not need
to meet the requirements for a PM CEMS under PS 11. The final rule also does provide for the use of a
PM CEMS to determine compliance with the filterable PM emission limit if the source elects to use this
approach (see the final preamble for further discussion).

The establishment of an operational limit is described in the final rule and is applied the same for all
sources, thus representing the operation of control equipment for all affected sources.

Comment 25: Commenter 17820 states that the EPA should designate filterable PM and not total PM as
a surrogate for the non-Hg metals standards. According to the commenter, however, if total PM is
retained the EPA should allow an alternative option to determine a unit-specific filterable PM limit and
the EPA should extend the option to use filterable PM as a surrogate for metals to oil units and to allow
compliance demonstrations through the use of CEMS.

Response to Comment 25: The rule has a filterable, not total, PM emissions limit.

Comment 26: Commenters 17812 and 17821 state that given the variability in testing and coal
properties, the requirement to maintain PM concentration at or below the highest 1-hour average
measured during the most recent performance test as proposed imposes a de facto unjustified reduction
in emission limit on those units using a PM CEMS. Commenter 17821 recommends deleting the
requirement in its entirety.

150


-------
Response to Comment 26: Under the final rule sources are allowed to establish different operating
limits monitored with a PM CPMS if they believe there is variability due to varying load conditions. The
final rule no longer requires monitoring with a PM CEMS. The final rule also does provide for the use of
a PM CEMS to determine compliance with the filterable PM emission limit if the source elects to use
this approach (see the final preamble for further discussion).

5.	Compliance costs if PM CEMS are not appropriate monitors for non-Hg HAP metals.

Comment 27: Commenters 17728 and 17775 state that if PM CEMS are not a realistic option for
monitoring PM as a surrogate, then the EPA must reconsider its assumptions that most sources will opt
to use PM as a surrogate, and should seriously consider the reasonableness and cost of the non-Hg HAP
metals testing option, including the impact of control device parametric monitoring options.

Response to Comment 27: PM CEMS are no longer required under the final rule. You may elect to
comply with an optional operating limit for PM. If you use this method to demonstrate continuous
compliance, you must install a PM CPMS and establish the operating limit during the initial compliance
test for filterable PM, total non-Hg HAP metals, or individual non-Hg HAP metals (or HAP metals
inclusive of Hg for liquid oil-fired units). If the PM CPMS option is not chosen, then sources are
required to perform quarterly testing to show compliance. The final rule also does provide for the use of
a PM CEMS to determine compliance with the filterable PM emission limit if the source elects to use
this approach (see the final preamble for further discussion).

6.	Concerns about the commercial readiness of PM CEMS.

Comment 28: Commenter 17818 states that it is their understanding that continuous PM monitoring
systems (PM CEMS) have been in operation for a number of years in other countries, and that a number
of PM monitors have been in operation in the U.S. for several years as a result of applicable state
requirements. According to the commenter, there are a number of commercially available continuous
PM monitoring technologies that are capable of meeting the EPA requirements. The commenter states
that information from the ICAC indicates that they have prepared a guidance document to help potential
purchasers of PM CEMS to prepare a bid specification for the solicitation of bids from particulate
monitor suppliers. Commenter agrees with the EPA that PM CEMS are commercially available and are
reasonable monitoring options for coal- and oil-fired units. It is the commenter's opinion that PM CEMS
are appropriate systems for monitoring compliance with the applicable provisions of the proposed rule.

Response to Comment 28: See response to comment 37.

Comment 29: Commenter 17796 supports the use of Hg CEMS but does not believe the use of PM
CEMS is supportable. According to the commenter, the EPA supports the "feasibility" of the PM CEMS
by pointing to few facilities which have installed CEMS and to the Performance Specifications for
evaluating compliance under 40 CFR Part 60. According to the commenter, there is no rigorous
demonstration that PM CEMs are feasible for general application, such as the process it went through to
finalize the Method 201/202 filterable and condensable particulate forms which it finalized in January of
2011. The commenter reviewed the Supporting & Related Material portion of the Docket for the PM
CEMS program and in over 3000 documents only found four that clearly dealt with PM CEMS, from
two facilities in Ohio and that simply reported the hourly measurements. The docket should show more
examples of facilities using PM CEMS and also the QA steps necessary for good data. According to the
commenter, the docket also needs to show that the PM CEMS equipment will be readily available and
also be able to be installed and troubleshot in a timely manner. The commenter states that a similar

151


-------
process with public input must be followed by the EPA to assure that information gathered from the
CEMS is valid and, more important to state agencies, that such information can be relied upon to
enforce in case of non-compliance.

Commenter 17796 also notes that the EPA's proposal to use CEMS as an option for PM compliance
only affects the filterable portion of the PM and relies on the concept that the condensable portion will
be addressed though the demonstration of "equivalency" between the CEMS and the stack testing during
the initial compliance tests. According to the commenter this is a very tenuous position to rely upon to
assure compliance with the total PM limits. The commenter notes that the New York SDEC has a
longstanding policy of requiring that the condensable portion of PM emissions be addressed in the
permitting process since this portion of the PM emissions are critical for the mitigation of health effects
associated with PM2.5. Thus, the commenter believes the PM CEMS approach is not adequately rigorous
to assure enforceability of the limits, nor allows for the necessary assurance of reducing PM levels to
address PM2.5 emissions. Finally, the commenter still has many questions as to reliability of PM CEMS
and how much experience with this equipment exists. The commenter states that the preamble stated
"several electric utility companies in the U.S. have now installed or are planning to install PM CEMs.
The commenter questions how many different types of EGUs have PM CEMS (broken down by unit
configuration and fuel type). Finally the commenter notes that the costs of PM CEMS are equivalent to
installing a Hg CEMS which is also required unless the source owner goes with sorbent traps which are
estimated to have less upfront costs but higher annualized costs.

Response to Comment 29: Under the final rule, you may elect to comply with an optional operating
limit for PM. If you use this method to demonstrate continuous compliance, you must install a PM
CPMS and establish the operating limit during the initial compliance test for filterable PM, total non-Hg
HAP metals, or individual non-Hg HAP metals (or HAP metals inclusive of Hg for liquid oil-fired
units). The operating limit for demonstrating continuous shall be based on the highest 1-hour average
measured during the most recent performance test. If you use a PM CPMS and associated operating
limit, you must conduct the applicable Method 5 or Method 29 test once annually and re-establish the
operating limit during each performance test. A PM CPMS does not need to meet the requirements for a
PM CEMS under PS 11. The final rule also does provide for the use of a PM CEMS to determine
compliance with the filterable PM emission limit if the source elects to use this approach (see the final
preamble for further discussion).

The final rule also includes the option to install and operate PM CEMS if the source chooses to comply
with the filterable PM emissions limit. To apply this option, the source would have to meet Performance
Specification 11 and procedure 2 of 40 CFR part 60 appendices B and F, respectively.

Comment 30: Commenter 17621 notes that there are almost 70 PM CEMS operating on EGUs in the
U.S. Over 40 are installed on wet stacks (following FGD systems). According to the commenter, PS-11
requires a minimum of 15 Method 5 test runs to develop a calibration curve for the CEMS and as a
practical matter, the lowest point on the calibration curve is the normal operating point of the CEMS.
According to the commenter, the only way to expand the operating range is to de-tune the power plant
control equipment to provide up-scale readings to the instrument while conducting the Method 5 manual
testing. The commenter states that while this approach has been demonstrated with some success on dry
stacks by de-tuning the ESP, it has not been attempted on units equipped with fabric filters. The
commenter asserts that wet stack applications present further challenges, since de-tuning an ESP
upstream of a wet FGD has less effect on the outlet emissions and increases the risk of producing off-
specification gypsum. According to the commenter, in these cases, the calibration curve for the PM
CEMS consists of the normal operating point and an artificial zero.

152


-------
According to the commenter there is not a lot of documentation available on the installed PM CEMS
equipment; however, all of the systems now installed on wet stacks have indicated some plugging
problems. The commenter asserts that usually this has been handled by frequent cleaning of the probes.
The commenter states that the experience at an EPRI demonstration project has shown similar issues,
with some systems working better than others. According to the commenter, all of the vendors continue
to make improvements and try alternatives. The commenter states that dry stack systems fare better,
especially where cross-stack installations are possible, though one particular model had problems with
data loss due to sunlight interference at the height of the day.

According to the commenter, the sensitivity of the PM CEMS is limited by the lowest filterable PM
emission that can be accurately and precisely measured by Method 5. The commenter states that in EPRI
sponsored PS-11 testing, the lowest range of PM emissions used for calibration was 2 to 5 milligrams
per cubic meter (mg/m3), approximately 0.002 to 0.005 lb/MMBtu. According to the commenter, this
level of sensitivity is adequate to measure filterable PM at the proposed total PM limits for existing coal-
fired EGUs (0.03 lb/MMBtu), but may not be sensitive enough to measure at the proposed total PM
limit for new coal-fired EGUs (approximately 0.005 lb/MMBtu). Commenter notes that while a lower
detection limit for Method 5 can be obtained by extending the sampling time, longer sampling times will
increase the time required to conduct the full 15 runs required by PS-11.

Response to Comment 30: The final rule no longer requires a PM CEMS for compliance monitoring.
Under the final rule, you may elect to comply with an optional operating limit for PM. If you use this
method to demonstrate continuous compliance, you must install a PM CPMS and establish the operating
limit during the initial compliance test for filterable PM, total non-Hg HAP metals, or individual non-Hg
HAP metals (or HAP metals inclusive of Hg for liquid oil-fired units). The operating limit for
demonstrating continuous shall be based on the highest 1-hour average measured during the most recent
performance test. If you use a PM CPMS and associated operating limit, you must conduct the
applicable Method 5 or Method 29 test once annually and re-establish the operating limit during each
performance test. A PM CPMS does not need to meet the requirements for a PM CEMS under PS 11.
The final rule also does provide for the use of a PM CEMS to determine compliance with the filterable
PM emission limit if the source elects to use this approach (see the final preamble for further
discussion).

Comment 31: Commenter 19033 is unaware of any PM CEMS that can measure both filterable and
condensable PM. The commenter has PM CEMS on three industrial boilers that it owns and operates
and they operate at a temperature of approximately 320 °F, in order to prevent water droplet
interference. According to the commenter, if the EPA intends that a PM CEMS be used to assure
compliance with the PM limit in Table 2, it needs to amend Table 2 to specify that the PM limit is
filterable PM, not total. The commenter states that in that manner, output from a PM CEMS, coupled
with the required part 75 flow and diluent monitors, can be used to provide PM emissions on a lb/mm
Btu basis. According to the commenter the EPA seems to be trying to control condensable PM by
specifying that the PM emission limit be on a total, rather than-filterable basis. The commenter states
that wet scrubber technology will provide condensable PM removal, in addition to acid gas removal, and
there is thus no need for the EPA to regulate condensable PM as part of this regulation with a specific
emission limit.

Response to Comment 31: The final rule no longer requires a PM CEMS for compliance monitoring.
Under the final rule, you may elect to comply with an optional operating limit for PM. If you use this
method to demonstrate continuous compliance, you must install a PM CPMS and establish the operating
limit during the initial compliance test for filterable PM, total non-Hg HAP metals, or individual non-Hg

153


-------
HAP metals (or HAP metals inclusive of Hg for liquid oil-fired units). The operating limit for
demonstrating continuous shall be based on the highest 1-hour average measured during the most recent
performance test. If you use a PM CPMS and associated operating limit, you must conduct the
applicable Method 5 or Method 29 test once annually and re-establish the operating limit during each
performance test. A PM CPMS does not need to meet the requirements for a PM CEMS under PS 11.
The final rule also does provide for the use of a PM CEMS to determine compliance with the filterable
PM emission limit if the source elects to use this approach (see the final preamble for further
discussion).

Comment 32: Commenter 17790 states that the accuracy of a PM CEMS should be considered when
setting an emission limit. The commenter states that establishing the "accuracy" of the PM CEMS is
accomplished by conducting a three-level Method 5 test but that unlike gaseous monitors (e.g., SO2 or
NOx CEMS), PM CEMS are not capable of routine calibration checks using calibration gases.

According to the commenter, the variability at low PM levels and insufficiency of frequent accuracy
checks may impact the reliability and accuracy of the PM monitors reading over time and provide a false
indication of compliance or non-compliance with a PM emission limit. Also according to the
commenter, PS- 11 certification requirements require de-tuning of PM control devices, without a
corresponding relief from current emission limitations and reporting requirements.

Response to Comment 32: The final rule no longer requires a PM CEMS for compliance monitoring.
Under the final rule, you may elect to comply with an optional operating limit for PM. If you use this
method to demonstrate continuous compliance, you must install a PM CPMS and establish the operating
limit during the initial compliance test for filterable PM, total non-Hg HAP metals, or individual non-Hg
HAP metals (or HAP metals inclusive of Hg for liquid oil-fired units). The operating limit for
demonstrating continuous shall be based on the highest 1-hour average measured during the most recent
performance test. If you use a PM CPMS and associated operating limit, you must conduct the
applicable Method 5 or Method 29 test once annually and re-establish the operating limit during each
performance test. A PM CPMS does not need to meet the requirements for a PM CEMS under PS 11.
The final rule also does provide for the use of a PM CEMS to determine compliance with the filterable
PM emission limit if the source elects to use this approach (see the final preamble for further
discussion).

Although PM CEMS are not required under the final rule, we believe that PM CEMS with a successful
correlation using PS-11, with the 95% confidence levels, will assure that the PM CEMS would have the
necessary certainty as a compliance monitor. Most all successful correlations achieve much tighter
statistical criteria than the minimum allowed under PS-11 and Procedure 2. Procedure 2 describes the
required audits to insure that subsequent measurements are stable and within acceptable limits, thereby
ensuring reliable compliance data.

Comment 33: Commenter 17790 states that the EPA must allow the use of Method 5B to demonstrate
compliance with PM limits. The commenter states that Method 5B is allowed for sources calibrating PM
CEMs under PS-11. According to the commenter, the method was developed for sources using wet
scrubbers and is routinely allowed for compliance stack tests. The commenter states that the EPA did
modify some of the requirements in Method 5 (filter temperature) which are consistent with Method 5B
objectives and thus should allow the complete use of the method.

Response to Comment 33: PM CEMS are no longer required under the final rule. Method 5 is the
reference compliance method in the final rule for the annual PM compliance test. The final rule also

154


-------
does provide for the use of a PM CEMS to determine compliance with the filterable PM emission limit
if the source elects to use this approach (see the final preamble for further discussion).

Comment 34: Commenter 17790 states that there is insufficient reliability in PM CEMS to give
accurate data for EGUs with low PM emissions (i.e., EGUs with FGD). The commenter states that its
Monroe Power Plant is currently hosting an EPRI PM CEMS Demonstration Project. According to the
commenter, the commenter's experience so far suggests that PM CEMS may not be reliable and
accurate monitors of stack gas particulates; the project has accumulated limited run time, with sub-
standard performance such as plugged monitors and extended down time.

Response to Comment 34: The final rule no longer requires a PM CEMS for compliance monitoring.
Under the final rule, you may elect to comply with an optional operating limit for PM. If you use this
method to demonstrate continuous compliance, you must install a PM CPMS and establish the operating
limit during the initial compliance test for filterable PM, total non-Hg HAP metals, or individual non-Hg
HAP metals (or HAP metals inclusive of Hg for liquid oil-fired units). The operating limit for
demonstrating continuous shall be based on the highest 1-hour average measured during the most recent
performance test. If you use a PM CPMS and associated operating limit, you must conduct the
applicable Method 5 or Method 29 test once annually and re-establish the operating limit during each
performance test. A PM CPMS does not need to meet the requirements for a PM CEMS under PS 11.
The final rule also does provide for the use of a PM CEMS to determine compliance with the filterable
PM emission limit if the source elects to use this approach (see the final preamble for further
discussion).

Although PM CEMS are no longer required under the final rule, section 2.4 of PS-11 stresses the
importance of planning for the specific effluent matrix and/or PM that might influence the correlation
and describes the process required to enhance the probability of obtaining a successful correlation and
the selection of the most appropriate CEMS for the installation. We believe that PM CEMS with a
successful correlation using PS-11, with the 95% confidence levels, will assure that the PM CEMS
would have the necessary certainty as a compliance monitor. Most all successful correlations achieve
much tighter statistical criteria than the minimum allowed under PS-11 and Procedure 2. Procedure 2
describes the required audits to insure that subsequent measurements are stable and within acceptable
limits, thereby ensuring reliable compliance data.

Comment 35: Several commenters (17681, 17638, 18831) disagree with using PM CEMS for
compliance for the following reasons. According to the commenters:

1.	The commenters believe PM CEMS have not proven to be reliable for the electric utility industry,

2.	The instruments are very expensive,

3.	The instruments measure only filterable PM, and

4.	The proposal to use a short-term total PM stack test to establish a continuous 30-day filterable limit
does not take into consideration any variability of the reference test method, fuel supply, the CEMS
itself or unit operations.

For these reasons, commenters request that the EPA require compliance for metals based on an annual
filterable PM test because EGUs are accustomed to conducting annual PM stack tests for SIP and NSPS
compliance.

Response to Comment 35: The final rule no longer requires a PM CEMS for compliance monitoring.
Under the final rule, you may elect to comply with an optional operating limit for PM. If you use this

155


-------
method to demonstrate continuous compliance, you must install a PM CPMS and establish the operating
limit during the initial compliance test for filterable PM, total non-Hg HAP metals, or individual non-Hg
HAP metals (or HAP metals inclusive of Hg for liquid oil-fired units). The operating limit for
demonstrating continuous shall be based on the highest 1-hour average measured during the most recent
performance test. If you use a PM CPMS and associated operating limit, you must conduct the
applicable Method 5 or Method 29 test once annually and re-establish the operating limit during each
performance test. A PM CPMS does not need to meet the requirements for a PM CEMS under PS 11.
The final rule also does provide for the use of a PM CEMS to determine compliance with the filterable
PM emission limit if the source elects to use this approach (see the final preamble for further
discussion).

Although PM CEMS are no longer required under the final rule, the EPA disagrees with the commenters
that indicate a general concern that PM CEMS are not an adequately reliable technology. PM CEMS
have been demonstrated for a variety of applications. PM CEMS performance specifications and QA
procedures have been around quite a while with PS-11 and Procedure 2 promulgated January 2004.

There have been at least 65 successful installations in the United States and in other countries. A
successful installation is obtained when a PM CEMS passes the PS-11 statistical criteria, thereby
demonstrating that an acceptable level of accuracy is achieved. PS-11 provides the steps in obtaining a
reliable successful correlation with reference methods, thereby ensuring compliance data that is
sufficient to determine compliance with PM emission limits. Most all successful correlations achieve
much tighter statistical criteria than the minimum allowed under PS-11 and Procedure 2. Procedure 2
describes the required audits to insure that subsequent measurements are stable and within acceptable
limits, thereby ensuring reliable compliance data.

Comment 36: Commenter 19197 states that the PM CEMS operating limit is proposed to be set at the
highest 1-hour average measured rate from the most recent performance test used to demonstrate
compliance with the total PM emissions limits. According to the commenter, the proposed methodology
is likely non-representative because the time period necessary to perform the total PM performance test
is relatively short, consisting of three 1- to 2-hour long simultaneous EPA Method 5 and Method 202
stack tests. According to the commenter, the resultant operating limit is only representative of the 3 to 6
hour PM control system operating period and consequently, the performance testing time period may not
represent typical PM control efficiencies. The commenter states that the testing might occur during a
highly controlled period, resulting in an overly restrictive filterable PM emissions operating limit. The
commenter offers an example of the potential subjectivity of the proposal. The commenter states that
during performance testing, hypothetical "Facility A's" baghouse particulate control system's
effectiveness might be very effective and the EPA Method 5 and Method 202 testing show very low
filterable and total PM emission rates while conversely, hypothetical "Facility B's" baghouse particulate
control effectiveness might be compromised during the EPA Method 5 and Method 202 performance
testing, barely showing compliance with the total PM limit. According to the commenter, consequently,
setting the filterable PM CEMS limit as proposed by using the highest 1-hour average measured Method
5 rate during the performance test will penalize the better performing "Facility A." The commenter
states that the PM CEMS limit determination methodology should not encourage operating with
marginal baghouse control effectiveness during performance testing.

Response to Comment 36: Under the final rule sources are allowed to establish different operating
limits monitored with a PM CPMS if they believe there is variability due to varying load conditions. The
final rule no longer requires monitoring with a PM CEMS. The final rule does provide for the use of a
PM CEMS to determine compliance with the filterable PM emission limit if the source elects to use this

156


-------
approach (see the final preamble for further discussion). Sources also may opt for quarterly testing with
reference methods to determine compliance.

Comment 37: Commenter 17975 states that they have discussed with vendors, the ability of the two
primary types of PM CEMS (light scattering or beta measurement) to measure high concentrations of
PM, such as are and would be emitted during SSM events, especially for units with non-energized ESPs
during such events. The commenter states that vendors have assured the commenter that if the
specifications call for measurements of high concentrations of PM then they can supply the appropriate
instrument packages. Commenter notes that there is nothing inherently limiting for either of these
technologies that would preclude their ability to measure high concentrations of PM and the fact that
reputable vendors confirm this makes it imperative that PM CEMS be required at all times, including
SSM time periods, when emissions are at their highest, especially for units with ESPs. Commenter
provides a short explanation of both types of CEMS.

Response to Comment 37: As mentioned elsewhere, the comment is moot, for the final rule no longer
contains emissions limits applicable during startup or shutdown periods and provides for affirmative
defense in the event of excess emissions that occur during a malfunction.

Comment 38: Commenter 17696 states that because of bad performance of PM CEMS on two of their
coal-fired units, they believe it is inappropriate for the EPA to require the use of PM CEMS for
compliance determinations without a reasonable alternative until reliable PM CEMS are commercially
available. The commenter believes that a reasonable alternative is to require periodic PM emission tests
when fuels change or when PM CEMS indicate, similar to a part 64 CAM approach. The commenter
believes it is not necessary to require fuel analyses or bimonthly Method 29 stack tests.

Response to Comment 38: Under the final rule sources are allowed to establish different operating
limits monitored with a PM CPMS if they believe there is variability due to varying load conditions. The
final rule no longer requires monitoring with a PM CEMS. The final rule does provide for the use of a
PM CEMS to determine compliance with the filterable PM emission limit if the source elects to use this
approach (see the final preamble for further discussion). Sources also may opt for quarterly testing with
reference methods to determine compliance.

Comment 39: Commenter 17705 states that the agency must address issues with PM CEMS technology
before mandating its use as a compliance methodology because PM CEMS are not yet widely deployed
across the utility industry and because the agency has made use of PM CEMS optional under 40 CFR
part 60, subparts D and Da. The commenter has no direct experience with PM CEMS but is aware that
the industry has ongoing concerns and states that the EPA shares at least some of these concerns based
on text included by the agency in a consent decree that requires a 2-year demonstration period for PM
CEMS. According to the commenter the language in the consent decree acknowledges that PM CEMS
technology is still in development. The commenter states that the EPA must also commit to providing a
simpler and more reliable way to calibrate PM CEMS because PS-11 can be difficult for sources with
highly efficient PM controls. The commenter states that the PS-11 procedures place source operators at
risk of exceeding permit limits, and the commenter requests that the EPA provide guidance to permitting
authorities that it is inappropriate to subject sources to enforcement proceedings when trying to achieve
the high dust loads required by PS-11. The commenter does not support the proposed alternative to PM
CEMS of conducting bimonthly Method 29 tests.

Response to Comment 39: The final rule no longer requires a PM CEMS for compliance monitoring.
Under the final rule, you may elect to comply with an optional operating limit for PM. If you use this

157


-------
method to demonstrate continuous compliance, you must install a PM CPMS and establish the operating
limit during the initial compliance test for filterable PM, total non-Hg HAP metals, or individual non-Hg
HAP metals (or HAP metals inclusive of Hg for liquid oil-fired units). The operating limit for
demonstrating continuous shall be based on the highest 1-hour average measured during the most recent
performance test. If you use a PM CPMS and associated operating limit, you must conduct the
applicable Method 5 or Method 29 test once annually and re-establish the operating limit during each
performance test. A PM CPMS does not need to meet the requirements for a PM CEMS under PS 11.
The final rule also does provide for the use of a PM CEMS to determine compliance with the filterable
PM emission limit if the source elects to use this approach (see the final preamble for further
discussion).

Although PM CEMS are no longer required under the final rule, the EPA disagrees with the commenters
that indicate a general concern that PM CEMS are not an adequately reliable technology. PM CEMS
have been demonstrated for a variety of applications. PM CEMS performance specifications and QA
procedures have been around quite a while with PS-11 and Procedure 2 promulgated January 2004.
There have been at least 65 successful installations in the United States and in other countries. A
successful installation is obtained when a PM CEMS passes the PS-11 statistical criteria, thereby
demonstrating that an acceptable level of accuracy is achieved. PS-11 provides the steps in obtaining a
reliable successful correlation with reference methods, thereby ensuring compliance data that is
sufficient to determine compliance with PM emission limits. Most all successful correlations achieve
much tighter statistical criteria than the minimum allowed under PS-11 and Procedure 2. Procedure 2
describes the required audits to insure that subsequent measurements are stable and within acceptable
limits, thereby ensuring reliable compliance data.

Comment 40: Multiple commenters (17402, 17681, 17716, 17737, 17758, 17820, 18014) characterize
PM CEMS as not measuring PM directly, and several commenters (17402, 17758, 18014) state that PM
CEMS calculate PM emissions based on reference method measurements that depend on the calibration
procedures and the inherent limitations of the measurement technology.

Response to Comment 40: The final rule no longer requires a PM CEMS for compliance monitoring.
Under the final rule, you may elect to comply with an optional operating limit for PM. If you use this
method to demonstrate continuous compliance, you must install a PM CPMS and establish the operating
limit during the initial compliance test for filterable PM, total non-Hg HAP metals, or individual non-Hg
HAP metals (or HAP metals inclusive of Hg for liquid oil-fired units). The operating limit for
demonstrating continuous shall be based on the highest 1-hour average measured during the most recent
performance test. If you use a PM CPMS and associated operating limit, you must conduct the
applicable Method 5 or Method 29 test once annually and re-establish the operating limit during each
performance test. A PM CPMS does not need to meet the requirements for a PM CEMS under PS 11.
The final rule also does provide for the use of a PM CEMS to determine compliance with the filterable
PM emission limit if the source elects to use this approach (see the final preamble for further
discussion).

Although PM CEMS are no longer required under the final rule, the EPA disagrees with the commenters
that indicate a general concern that PM CEMS are not an adequately reliable technology. PM CEMS
have been demonstrated for a variety of applications. PM CEMS performance specifications and QA
procedures have been around quite a while with PS-11 and Procedure 2 promulgated January 2004.
There have been at least 65 successful installations in the United States and in other countries. A
successful installation is obtained when a PM CEMS passes the PS-11 statistical criteria, thereby
demonstrating that an acceptable level of accuracy is achieved. PS-11 provides the steps in obtaining a

158


-------
reliable successful correlation with reference methods, thereby ensuring compliance data that is
sufficient to determine compliance with PM emission limits. Most all successful correlations achieve
much tighter statistical criteria than the minimum allowed under PS-11 and Procedure 2. Procedure 2
describes the required audits to insure that subsequent measurements are stable and within acceptable
limits, thereby ensuring reliable compliance data.

Comment 41: Multiple commenters (17402, 17716, 17725, 17758, 17790, 17820, 18014, 18498,
18023) believe that PS-11 creates a significant risk of "false positives" due to instrument error because
of PS-ll's generous statistical performance criteria. These commenters also express doubts that PM
CEMS can produce representative measurements over the entire range of boiler operations because
calibration of the instrument does not occur across all load ranges. According to commenters, these
periods of operation result in transient flue gas conditions causing changes in particle density,
morphology, size distribution or stratification of PM within the flue that are not reflected in the
correlation of the instrument. The commenters believe some of the preceding issues can be addressed in
the final rule, but the commenters do not think the technology is usable as a direct indicator of
compliance as proposed.

Response to Comment 41: Although PM CEMS are no longer required under the final rule, section 2.4
of PS-11 stresses the importance of planning for the specific effluent matrix and/or PM that might
influence the correlation and describes the process required to enhance the probability of obtaining a
successful correlation and the selection of the most appropriate CEMS for the installation. We believe
that PM CEMS with a successful correlation using PS-11, with the 95% confidence levels, will assure
that the PM CEMS would have the necessary certainty as a compliance monitor. Most all successful
correlations achieve much tighter statistical criteria than the minimum allowed under PS-11 and
Procedure 2. Procedure 2 describes the required audits to insure that subsequent measurements are stable
and within acceptable limits, thereby ensuring reliable compliance data. Applying a technology suitable
for a particular application would naturally take some planning. Section 2.4(1) of PS-11 states that you
should select a PM CEMS that is appropriate for your source. Manufacturers of beta gauge instruments
have demonstrated that the calibration curve does not change as the fuel mix changes or load changes.
Vendors have guaranteed that their PM CEMS will meet the PS-11 criteria for multi-fuel boilers. PS-11
provides for situations where multiple correlations may be needed for a PM CEMS technology (see
Section 2.3 of PS-11). Based on this information, the final rule does provide for the use of a PM CEMS
to determine compliance with the filterable PM emission limit if the source elects to use this approach
(see the final preamble for further discussion).

Comment 42: Several commenters (17402, 17681, 17716, 17740) state that treating PM CEMS as a
direct indicator of compliance is inappropriate because the EPA's floor analysis is based on reference
method data, and the proposed limits do not reflect the underlying uncertainty of the PM CEMS.

Response to Comment 42: The final rule no longer requires a PM CEMS for compliance monitoring.
Under the final rule, you may elect to comply with an optional operating limit for PM. If you use this
method to demonstrate continuous compliance, you must install a PM CPMS and establish the operating
limit during the initial compliance test for filterable PM, total non-Hg HAP metals, or individual non-Hg
HAP metals (or HAP metals inclusive of Hg for liquid oil-fired units). The operating limit for
demonstrating continuous shall be based on the highest 1-hour average measured during the most recent
performance test. If you use a PM CPMS and associated operating limit, you must conduct the
applicable Method 5 or Method 29 test once annually and re-establish the operating limit during each
performance test. A PM CPMS does not need to meet the requirements for a PM CEMS under PS 11.
The final rule also does provide for the use of a PM CEMS to determine compliance with the filterable

159


-------
PM emission limit if the source elects to use this approach (see the final preamble for further
discussion).

Comment 43: Commenter 17761 states that if emission reductions are mandated, it must be recognized
that PM CEMS have not been widely deployed and their utilization has been largely limited to
requirements imposed by the EPA in NSR consent decrees with escape clauses in place. The commenter
submits that there is insufficient experience with PM CEMS being utilized for compliance purposes to
make them a viable tool to judge compliance with these standards. To the extent that stack testing is an
alternative, the commenter submits that there is currently a shortage of qualified stack testers. Due to the
level of precision required when conducting such important compliance tests, the commenter has
consistently had to waive its procurement guidelines (and pay additional costs) in an effort to obtain
quality firms that follow proper procedures after having experiences with failed PM stack test results
that are due to human error.

Response to Comment 43: Although PM CEMS are no longer required under the final rule, the EPA
disagrees with the commenters that indicate a general concern that PM CEMS are not an adequately
reliable technology and are have not been widely deployed. PM CEMS have been demonstrated for a
variety of applications. PM CEMS performance specifications and QA procedures have been around
quite a while with PS-11 and Procedure 2 promulgated January 2004. There have been at least 65
successful installations in the United States and in other countries. A successful installation is obtained
when a PM CEMS passes the PS-11 statistical criteria, thereby demonstrating that an acceptable level of
accuracy is achieved. PS-11 provides the steps in obtaining a reliable successful correlation with
reference methods, thereby ensuring compliance data that is sufficient to determine compliance with PM
emission limits. Most all successful correlations achieve much tighter statistical criteria than the
minimum allowed under PS-11 and Procedure 2. Procedure 2 describes the required audits to insure that
subsequent measurements are stable and within acceptable limits, thereby ensuring reliable compliance
data.

Comment 44: Commenter 17871 states that PM CEMS are not yet advanced enough to provide reliable
and accurate data at a reasonable cost. The commenter states that state agencies regularly determine that
PM CEMS are not reasonably cost-effective monitoring devices-a point with which the EPA has agreed.
See 70 FR 7908 (Feb. 16, 2005) (justifying the use of COMS because CEMS are "significantly more
expensive to purchase and maintain than COM ..."). The commenter states that the requirement for PM
CEMS is particularly problematic for EGUs with very low mass emissions of filterable PM. The
commenter states that the MACT requires developing a correlation between the PM CEMS and a
reference method (Method 5) using the PS-11, and this involves conducting 15 correlation runs between
Method 5 and the PM CEMS over a range of PM concentrations. The commenter asserts that
considering the inherent lack of precision of Method 5 at low PM concentrations, it will be very difficult
to demonstrate the correlation coefficient (>0.85) required for the initial site specific certification of the
PM CEMS. The commenter also asserts that it is also unclear how a range of PM concentrations can be
created during performance testing when a fabric filter baghouse is used for particulate control.

Response to Comment 44: Although PM CEMS are no longer required under the final rule, section 2.4
of PS-11 stresses the importance of planning for the specific effluent matrix and/or PM that might
influence the correlation and describes the process required to enhance the probability of obtaining a
successful correlation and the selection of the most appropriate CEMS for the installation. We believe
that PM CEMS with a successful correlation using PS-11, with the 95% confidence levels, will assure
that the PM CEMS would have the necessary certainty as a compliance monitor. Most all successful
correlations achieve much tighter statistical criteria than the minimum allowed under PS-11 and

160


-------
Procedure 2. Procedure 2 describes the required audits to insure that subsequent measurements are stable
and within acceptable limits, thereby ensuring reliable compliance data. Precision of the Method 5 tests
may be improved by employing paired trains for each run to sort out the imprecise test runs. PS-11 has a
special correlation coefficient of >0.75 for low-emitting sources and section 8.6 of PS-11 allows sources
to obtain zero point data to aid in achieving correlation criteria.

Comment 45: Commenter 18447 is concerned about the accuracy and reliability of a PM CEMS and
under the proposed rule their units would require monthly stack tests that are excessive and expensive.

Response to Comment 45: Although PM CEMS are no longer required under the final rule, EPA
disagrees with the commenters who indicate a general concern that PM CEMS are not an adequately
reliable technology. PM CEMS have been demonstrated for a variety of applications. PM CEMS
performance specifications and QA procedures have been around quite a while with PS-11 and
Procedure 2 promulgated January 2004. There have been at least 65 successful installations in the
United States and in other countries. A successful installation is obtained when a PM CEMS passes the
PS-11 statistical criteria, thereby demonstrating that an acceptable level of accuracy is achieved. PS-11
provides the steps in obtaining a reliable successful correlation with reference methods, thereby ensuring
compliance data that is sufficient to determine compliance with PM emission limits. Most all successful
correlations achieve much tighter statistical criteria than the minimum allowed under PS-11 and
Procedure 2. Procedure 2 describes the required audits to insure that subsequent measurements are stable
and within acceptable limits, thereby ensuring reliable compliance data. Under the final rule we have
dropped the requirement for monthly stack tests.

Comment 46: Commenter 18935 recommends that the EPA develop a guidance document for
performance specification testing of PM CEMS that reflects recent experience with current control
technologies and emission levels. The commenter also suggests that sources be allowed a phase in
period for PM CEMS, perhaps allowing sources to conduct frequent periodic monitoring by
conventional reference methods until a PM CEMS is installed. According to the commenter, it has
assisted clients with the performance specification testing of particulate CEMS and found that many
sources have concerns about varying the process or control equipment conditions to produce three
varying loads of particulate emissions. The commenter states that sophisticated particulate emission
control systems perform consistently and reliably when matched to source characteristics - changing
operations to produce alternate emission levels is not an easy matter. According to the commenter, while
PS-11 allows for the generation of low level emission data by removing the probe, it is not clear if
reference method testing using a Method 5, 51, or 17 sampling train needs to be conducted during the
same time (if so, these methods are not really designed for ambient particulate monitoring).

Response to Comment 46: PM CEMS are no longer required under the final rule. You may elect to
comply with an optional operating limit for PM. If you use this method to demonstrate continuous
compliance, you must install a PM CPMS and establish the operating limit during the initial compliance
test for filterable PM, total non-mercury HAP metals, or individual non-Hg HAP metals. The operating
limit for demonstrating continuous shall be based on the highest 1-hour average measured during the
most recent performance test. If you use a PM CPMS and associated operating limit, you must conduct
the applicable Method 5 or Method 29 test once annually and re-establish the operating limit during each
performance test. A PM CPMS does not need to meet the requirements for a PM CEMS under PS 11.

6. PM CEMS certification issues.

161


-------
Comment 47: Commenters 17800 and 17914 request clarification on the procedures to be used for
certification of PM CEMS. In order to certify a PM CEMS using PS-11 procedures, the PM CEMS must
be correlated using a three point curve with the reference method data. According to the commenters, in
order to generate the three PM loads required by PS-11 (section 8.6) it is necessary to partially disable
the particulate control device to increase/decrease the PM mass loading to establish a valid correlation
curve, but this may not be practical or possible for certain particulate control technologies, as there is no
way to temporarily, partially disable fabric filters not equipped with flue gas bypass dampers to generate
higher PM emissions. In addition, state the commenters, state or local regulatory permits may preclude a
source from operating at PM levels in excess of the permitted levels, and without an exemption, it would
not be possible to pass the correlation tests in PS-11. Commenter 17914 states that in addition, for IGCC
there is no PM control device since the combustion turbine is burning synthetic gas fuel, and it may not
be possible to establish an adequate correlation of PM as per PS-11 requirements for certain control
devices/plant configurations.

Comment 48: Commenter 17801 states that PS-11 requires a correlation with reference method tests
performed over the full range of the PM CEMS responses that corresponds to the normal operating
conditions of the source and control device and that due to a lack of post combustion emissions control,
IGCC syngas-fueled turbines are not able to vary PM emissions to achieve a valid correlation. The
commenter states that PM spiking is an option (though it hasn't yet been demonstrated and not
recommended by GE on a combustion turbine), but these systems are still in development, and may not
even be appropriate, safe or possible to inject PM into a combustion turbine. Commenter further notes
that PS-11 requires that the confidence interval (CI) and the Tolerance Interval half range (TI) are both
calculated as a percent of the emission limit; according to the proposed EGU MACT, the limit would be
set by the performance testing for initial compliance and filterable PM is a surrogate for non-Hg metal
HAP, and the particulate limit (which includes condensables) would not apply to the correlation; and
depending on the results, it may be impossible to meet the specifications using a limit set in this manner.
Therefore, states the commenter, compliance with the PM limits should be demonstrated via the
standard PM emissions stack testing methodologies (Methods 5/202). The commenter suggests that
opacity monitors can be used on a continuous basis as a compliance indicator.

Response to Comments 47 - 48: PM CEMS are no longer required under the final rule. You may elect
to comply with an optional operating limit for PM. If you use this method to demonstrate continuous
compliance, you must install a PM CPMS and establish the operating limit during the initial compliance
test for filterable PM, total non-Hg HAP metals, or individual non-mercury HAP metals. The operating
limit for demonstrating continuous shall be based on the highest 1-hour average measured during the
most recent performance test. If you use a PM CPMS and associated operating limit, you must conduct
the applicable Method 5 or Method 29 test once annually and re-establish the operating limit during each
performance test. A PM CPMS does not need to meet the requirements for a PM CEMS under PS 11.

Although PM CEMS are no longer required under the final rule, there are several things that help with
obtaining a correlation for a low-emitting source. Precision of the Method 5 tests may be improved by
employing paired trains for each run to sort out the imprecise test runs. PS-11 has a special correlation
coefficient of >0.75 for low-emitting sources and section 8.6 of PS-11 allows sources to obtain zero
point data to aid in achieving correlation criteria. We recommend that sources operate their PM CEMS
over a correlation test planning period of sufficient duration to identify the full range of operating
conditions and PM emissions to be used in your PM CEMS correlation test to avoid operation in excess
of the permitted levels. Based on this information, the final rule does provide for the use of a PM CEMS
to determine compliance with the filterable PM emission limit if the source elects to use this approach
(see the final preamble for further discussion).

162


-------
7. Problems with "floating limits."

Comment 49: Commenters 17623 and 17774 conclude that the operating limits for PM CEMS will be
"floating limits" in which a facility will be measuring filterable particles with its CEMS, but its actual
limit is based on the performance testing which measures total PM. According to commenters, as
proposed, the "floating limits" will create uncertainty in the regulated community and will be
detrimental to the application of the Utility MACT. In light of the measurement problems caused by a
total PM limit, one commenter requests that the EPA change the PM surrogate standard from a total PM
standard to one based only on filterable PM because the commenter believes it will allow for a clearer
target that will not change as operating conditions change.

Response to Comment 49: PM CEMS are no longer required under the final rule. You may elect to
comply with an optional operating limit for PM. If you use this method to demonstrate continuous
compliance, you must install a PM CPMS and establish the operating limit during the initial compliance
test for filterable PM, total non-mercury HAP metals, or individual non-mercury HAP metals (or HAP
metals inclusive of mercury for liquid oil-fired units). The operating limit for demonstrating continuous
shall be based on the highest 1-hour average measured during the most recent performance test. If you
use a PM CPMS and associated operating limit, you must conduct the applicable Method 5 or Method
29 test once annually and re-establish the operating limit during each performance test. A PM CPMS
does not need to meet the requirements for a PM CEMS under PS 11. The final rule also does provide
for the use of a PM CEMS to determine compliance with the filterable PM emission limit if the source
elects to use this approach (see the final preamble for further discussion).

Comment 50: Commenters 17714 and 17756 state that under the proposed rule each unit's operating
limit is confirmed or reestablished during subsequent performance tests and this could result in
progressively tighter limits over time based on the unit's most recent test. Commenters believe it is
inappropriate and inconsistent with the CAA to tighten a limit based on test results that show lower
emissions from a previous test. Commenter 17756 states that their experience with PM CEMS data from
well-controlled units show that compliance with a limit established in this way cannot be maintained on
a continuous, 30-day rolling average basis and that the proposed total PM limit is unworkable because it
fails to provide a single, known standard to be met.

Response to Comment 50: PM CEMS are no longer required under the final rule. You may elect to
comply with an optional operating limit for PM. If you use this method to demonstrate continuous
compliance, you must install a PM CPMS and establish the operating limit during the initial compliance
test for filterable PM, total non-Hg HAP metals, or individual non-Hg HAP metals (or HAP metals
inclusive of Hg for liquid oil-fired units). The operating limit for demonstrating continuous shall be
based on the highest 1-hour average measured during the most recent performance test. If you use a PM
CPMS and associated operating limit, you must conduct the applicable Method 5 or Method 29 test once
annually and re-establish the operating limit during each performance test. A PM CPMS does not need
to meet the requirements for a PM CEMS under PS 11. The establishment of an operational limit is
described in the final rule and is applied the same for all sources, thus representing the operation of
control equipment for all affected sources. The final rule also does provide for the use of a PM CEMS to
determine compliance with the filterable PM emission limit if the source elects to use this approach (see
the final preamble for further discussion).

Comment 51: Several commenters (17655, 17752, 18023) state thatPM CEMS operating limits
established by unit testing would be unwise and unwarranted because such operating limits could be far
below the regulatory limit. According to the commenters it is conceivable that an EGU could meet the

163


-------
total PM performance test standard by a wide margin (e.g., actual Method 5 results during performance
test <0.010 lb PM/MMBtu) but no matter how well the unit performs during performance tests, the
proposal stipulates that the unit must continue to operate at the same filterable PM emissions rate (as
determined by PM CEMS) indefinitely. The commenters state that the "operating limit" for filterable
PM reflects a limit on the only fraction of total PM removed by standard air emission control equipment.
Commenter 17655 believes that this is a radical departure from past agency standard-setting, which has
consistently recognized that control equipment performance varies over time, especially in units like
power generation equipment that must operate for extended periods between maintenance outages. The
commenter conjectures that the "EPA apparently assumes that condensable PM is both an indeterminate
and widely varying quantity that has the capability of throwing an affected EGU out of compliance...."
The commenter contends that the agency offers no evidence that the condensable PM fraction can be
determinative of compliance with the non-Hg metals standard, and the commenter believes that
condensable PM is instead a relatively fixed increment during normal operation. Based on the
commenter's assumption that the condensable PM rate is relatively constant, the commenter
recommends that the condensable PM emission rate (lb condensable PM/MMBtu) measured by the
reference method in the most recent performance test should be utilized as a constant value in the
following equation to determine the hourly emission rate in compliance calculations for the 0.03 lb
PM/MMBtu MACT limit for existing sources:

Calculated tPM for comparison to standard- (cPM fr0m most recent performance test) (fPMfrom pm CEMS or CAm)

Commenter 17655 concludes that the "operating limit" should not be expressed as being equal to the
filterable PM measured during performance tests, but rather the operating limit for sources subject to the
total PM limit of 0.03 lb PM/MMBtu should be calculated as follows after each performance test:

Operating Limit — 0.03 lb tPM/MMBtu - cPM from most recent performance test

Comment 52: Commenter 17716 acknowledges that their recommended methodology of determining a
filterable operating limit (by subtracting the condensable PM measured during the performance test from
the total PM MACT limit) is not without its own flaws, given the bias and uncertainty associated with
formation of sulfate and nitrate artifacts in Method 202 (that have nothing to do with metals); however,
it does introduce a margin for variability into the compliance process that better reflects normal
operating conditions. Commenters 17716 and 17758 also state that establishing a fixed filterable PM
operating limit value is necessary for determining the acceptability of the tolerance interval and
confidence interval results for PS-11.

Response to Comments 51 - 52: PM CEMS are no longer required under the final rule. You may elect
to comply with an optional operating limit for PM. If you use this method to demonstrate continuous
compliance, you must install a PM CPMS and establish the operating limit during the initial compliance
test for filterable PM, total non-Hg HAP metals, or individual non-Hg HAP metals (or HAP metals
inclusive of Hg for liquid oil-fired units). The operating limit for demonstrating continuous shall be
based on the highest 1-hour average measured during the most recent performance test. If you use a PM
CPMS and associated operating limit, you must conduct the applicable Method 5 or Method 29 test once
annually and re-establish the operating limit during each performance test. A PM CPMS does not need
to meet the requirements for a PM CEMS under PS 11. The final rule also does provide for the use of a
PM CEMS to determine compliance with the filterable PM emission limit if the source elects to use this
approach (see the final preamble for further discussion).

164


-------
Comment 53: Commenter 17758 believes without a filterable PM emissions limit in the final rule, the
PM CEMS compliance approach is unworkable and inconsistent with the performance criteria of PS-11.
Commenter 17716 believes that allowing sources to substitute a total PM limit for a filterable PM limit
for PS-11 purposes is appropriate because the total PM limit would effectively represent the highest
potential filterable PM limit where condensable emissions are reduced to zero.

Response to Comment 53: PM CEMS are no longer required under the final rule. You may elect to
comply with an optional operating limit for PM, using the PM monitoring as a PM CPMS. The final rule
also does provide for the use of a PM CEMS to determine compliance with the filterable PM emission
limit if the source elects to use this approach (see the final preamble for further discussion).

Comment 54: Commenters 17912 and 17798 state that the proposed rule that establishes a long-term
compliance limitation based upon only a few hours of test results fails to take into account the court's
holdings that the EPA must establish MACT standards which include all operating scenarios including
variability which always occurs.

Response to Comment 54: The agency disagrees with the commenters, for the PM emissions limit
includes a variability component determined using ICR Part II data and the UPL calculation.

Comment 55: Commenters 17913 and 19114 state that the proposed approach punishes a unit that has
low PM emissions because the performance test will establish the condensable emissions from each unit,
and the subsequent "filterable PM limit" should be equal to the total PM limit in the regulation minus
the measured condensable PM emissions. Commenters note that the approach will reward facilities that
are able to increase their emissions right up to the total PM limit during the performance test, so as to
obtain the least restrictive subsequent "filterable PM limit." According to the commenters, the goal of
the regulation should be to ensure that facilities maintain emissions below the given emission standard
in the regulation; this is achieved by having a facility demonstrate that filterable PM measured with a
CEMS in combination with condensable PM measured during a performance test do not exceed the
given total PM emission standard. Commenter 19114 notes that units that employ a baghouse will be out
of compliance as often as units equipped with precipitators due to the tighter unit-specific PM limit that
would be established as a result of the required performance stack test. For example, states the
commenter, a unit equipped with a baghouse may have emissions during the performance testing of
0.008 lb/mmBTU for filterable PM and 0.012 lb/mmBTU for condensable PM thereby passing the
performance test; the unit would then have to meet a 0.008 lb/MMBTU limit on its PM CEMS. The
commenter states that a unit equipped with an ESP may have emissions during the performance test of
0.02 lb/MMBTU for filterable PM and 0.01 lb/MMBTU for condensable PM, thereby passing the
performance test; this unit would then have a 0.02 lb/MMBTU limit on its PM CEMS. The commenter
states that the baghouse is doing a much better job of controlling PM, but the manner in which the
proposed rule governs ongoing operations does not give the unit with the baghouse credit for its low
emissions. According to the commenter, the limits for the baghouse unit should be calculated as the
proposed Total PM limit, 0.03 lb/MMBTU, less the condensable fraction, 0.012 lb/MMBTU, to give the
source its filterable PM CEMS limit of 0.018 lb/MMBTU; this approach would meet the spirit of the
proposed rule by limiting a source to the MACT floor, while giving the source credit for good
performance.

Response to Comment 55: Monitoring of total PM is no longer required in the final rule. PM CEMS
are no longer required under the final rule. You may elect to comply with an optional operating limit for
PM. See the response to Comment 53 above.

165


-------
Comment 56: Multiple commenters (17655, 17716, 17725, 17752, 17881, 18498, 18023) oppose the
proposed procedure for deriving an operating limit based strictly on the filterable PM emission rate
during periodic performance tests, and provide the following reasons:

1.	According to the commenters, an operational limit equal to filterable PM at the time of testing would
reflect an unrealistic expectation of future performance. For example, state the commenters, a fabric
filter always performs well for particulate control but, like any other equipment, would be expected
to work best when new. It would be unreasonable to hold any equipment to the same level of
performance after years of operation (even with frequent maintenance).

2.	According to the commenters, the source's margin of compliance may be completely lost depending
on the vagaries of the situation at the time of a performance test. According to the commenters, if the
combination of normal operating conditions at the time of the performance test enables the unit to
operate on the lower end of the normal operating range, the PM operating limit will be unattainably
low during operating conditions on the higher end of the normal range. The commenters state that
the proposed methodology eliminates the compliance margin for sources with very low emissions on
the day of the performance test, yet the opposite result may occur for a unit that barely meets
emissions limits due to challenging conditions on the day of the performance test.

3.	According to the commenters, the consequence of losing the compliance margin encourages
operators to reduce their risk of non-compliance by reverting to a compliance option other than PM
CEMS.

4.	According to the commenters, the proposed methodology encourages operators to run performance
tests on "the ragged edge" of compliance, and the MACT regulations should not encourage operators
to conduct compliance tests at sub-optimal conditions. Commenters (18023, 17798, 17912) state that
the proposed method provides a disincentive for installing controls, or operating the control in a
manner that allows for a reasonable margin of compliance.

5.	Commenter 18023 believes the proposed method for establishing a PM CEMS operating limit yields
a site-specific limitation that is inconsistent with the MACT program's goal of uniform standards.

6.	According to the commenters, an exceedance of the PM CEMS operating limit does not necessarily
indicate actual emissions were above the underlying PM standard or non-Hg HAP standard.

Response to Comment 56: The final rule requires the use of a PM CPMS for an operational limit and
does not enforce a numeric PM limit. If you use this method to demonstrate continuous compliance, you
must install a PM CPMS and establish the operating limit during the initial compliance test for filterable
PM, total non-Hg HAP metals, or individual non-Hg HAP metals (or HAP metals inclusive of Hg for
liquid oil-fired units). The operating limit for demonstrating continuous shall be based on the highest 1-
hour average measured during the most recent performance test. The source has the option to measure
non-Hg HAP metals with a reference method each quarter. If you use a PM CPMS and associated
operating limit, you must conduct the applicable Method 5 or Method 29 test once annually and re-
establish the operating limit during each performance test. Any degradation of the control equipment
will be accounted for in the yearly reestablishment of the PM operational limit and the compliance
margin will change accordingly. A PM CPMS does not need to meet the requirements for a PM CEMS
under PS 11. The final rule also does provide for the use of a PM CEMS to determine compliance with
the filterable PM emission limit if the source elects to use this approach (see the final preamble for
further discussion).

Under the final rule, sources are allowed to establish different operating limits monitored with a PM
CPMS if they believe there is variability due to varying load conditions. The final rule no longer
requires monitoring with a PM CEMS. Establishment of the operating limit during the initial compliance
test for filterable PM, total non-mercury HAP metals, or individual non-mercury HAP metals using the

166


-------
highest 1-hour average measured, along with allowing more than one operational limit for different load
conditions, and a 30-day rolling average should provide certainty of compliance for the source for EGU
owners or operators who choose to use a PM CPMS. Should EGU owners or operators choose not to
have to develop, monitor, and then maintain the EGUs in accordance with an operating limit, they could
choose to use a PM CEMS or quarterly emissions testing.

Comment 57: Commenter 17808 recommends changing the treatment of condensable PM for units
using PM CEMS to establish an operating limit on filterable PM. The commenter provides the following
example of why the proposed treatment of condensable PM is inequitable with regard to emissions of
metals: For instance, states the commenter, in the initial compliance demonstration for Facility A, an
existing coal-fired power plant with heat input >8,300 Btu/lb, shows total PM emissions of 0.020
lb/MMBtu with 50 percent filterable and 50 percent condensable PM, a facility-specific filterable PM
limit of 0.010 lb/MMBtu would be established. However, states the commenter, an identical Facility B
with the same total PM emissions but a higher ratio of filterable PM to condensable PM, such as 75
percent, would establish a filterable PM limit of 0.015 lb/MMBtu. According to the commenter, this
method is inherently uncertain, and could result in a facility having a variable emissions target.
Additionally, states the commenter, this method results in unfairly "ratcheting down" the standard on
some units and introduces a new set of problems.

Response to Comment 57: PM CEMS are no longer required under the final rule. You may elect to
comply with an optional operating limit for PM. . See the response to Comment 53.

Comment 58: Commenter 17774 states that the use of a total PM surrogate presents a host of problems
including:

1.	According to the commenter, the EPA's use of a condensable PM standard has the effect of increasing
the stringency of the PM rate, as compared to an emission rate for PM that applies solely to filterable
PM emissions.

2.	According to the commenter, the total PM standards are problematic because condensable PM is very
difficult to measure and thus proxies must be used for monitoring.

3.	According to the commenter, PM CEMS data simply cannot be used to measure compliance in
conjunction with a rule imposing a limit on total PM without introducing considerable uncertainty into
the compliance guidelines. The commenter states that the CEMS technology is quite different from the
formula the EPA used to set the total PM standard. According to the commenter, a PM CEMS monitors
only filterable PM emissions, not condensable emissions, and therefore cannot be used to set a total PM
limit; because of this, the limits for PM will have to be established by PM performance tests, which are
the only process that can measure both filterable and condensable particulates.

4.	According to the commenter, the limits for PM do not allow for variability in testing or operating
conditions because they are based on the particular circumstances of one stack test. The commenter
states that this lack of a variability calculation is contrary to the requirements for setting a MACT
standard; if the EPA retains a total PM standard, it must add a variability factor to the requirements to
reflect the full range of conditions under which sources are operating. The commenter states that it is not
feasible to require numerous stack tests, as each is expensive and time-consuming, nor is it acceptable to
base a standard on isolated stack testing conditions alone.

Response to Comment 58: Measurement of condensable PM is no longer required under the rule.

167


-------
8.	Variability of reference method data from scrubbed units.

Comment 59: Commenter 17675 states that stack tests completed since installation of scrubbers
indicates filterable PM is very low and that annual condensable PM and filterable PM test data indicates
there are no consistent ratios for condensable PM, filterable PM, or total PM from the commenter's
scrubbed units. Based on these highly variable and consistently low PM data, the commenter believes it
will be nearly impossible to develop an accurate correlation curve for PM CEMS. In lieu of the PM
CEMS option, the commenter requests that the final rule include an LEE testing option for sources
consistently performing at emission rates much lower than the PM standard. The commenter requests
that such a PM LEE option preclude regular or additional Method 29 tests.

Response to Comment 59: Measurement of condensable PM is no longer required under the new rule.
The final rule does include the LEE option with less frequent performance testing.

Comment 60: Commenters 17383 and 19121 state that trying to use a PM CEMS that was designed to
measure filterable PM for measuring total PM is questionable at best and that based on the commenter's
limited testing, the ratio of condensable PM to filterable PM is highly variable. According to the
commenters, under these circumstances, correlation of the PM monitor would be difficult if not
impossible. Commenter 19121 states that the inclusion of condensable PM fractions in the limit hints at
trying to control PM2.5 precursors, which is better managed under another CAA program.

Response to Comment 60: Measurement of condensable PM is no longer required under the new rule.
PM CEMS are no longer required in the final rule.

Comment 61: Commenter 18443 states that the EPA cannot require sources to set filterable PM
operating limits with no compliance margin and that for units that emit low concentrations of PM, this is
an extremely onerous requirement with which it is likely impossible to comply. Units with wet FGDs,
for example, typically emit filterable PM at or below detection levels. According to the commenter, a
limit set at these levels would be below the detection level of a PM CEMS and allow no compliance
margin. The commenter states that the EPA has not justified this type of requirement and it must be
eliminated from the final rule.

Response to Comment 61: PM CEMS are no longer required in the final rule. PM CPMS should be
able to operate at the low PM operational levels expected at sources and should not be below the
detection limits.

9.	Need for PM CEMS availability criteria.

Comment 62: Commenters 17638 and 17681 state that the EPA must establish minimum CEMS data
availability and deviation requirements and that the operating costs included in the proposal fail to
account for all the maintenance costs associated with PM CEMS. One commenter requests that the EPA
revise those operating cost estimates.

Response to Comment 62: PM CEMS are no longer required in the final rule.

10.	Table 4 requirement to convert PM CEMS readings to dry basis.

Comment 63: Several commenters (17716, 17725, 18014) advise that the requirement in Table 4 of the
proposed rule to convert PM CEMS data to a "mg/ dscm" basis creates unnecessary problems because

168


-------
most PM CEMS do not measure on a dry basis but are correlated to "mg/wscm." According to the
commenters, switching to a mg/dscm is problematic because the current measurement must be converted
to a dry basis which would require a source to monitor stack moisture or use a some type of default
value. Notwithstanding the inadvisability of using the PM measured during the compliance test as an
operating limit, state the commenters, if the final rule retains this provision, sources should be allowed
to use either the average 30-day correlated analyzer response (mg/wacm, mg/wscm, etc.) or lb/MMBtu
values as an indicator.

Comment 64: Commenter 17881 states that under section 63.10021(a)(l l)(ii) diluent data (O2/CO2) is
only needed for the lb/MMBtu rate calculation or concentration values corrected back to a diluents gas
concentration (which is not the case, as the PM filterable operating limit is mg/dscm and is not corrected
back to a specific diluent level).

Response to Comments 63-64: PM CEMS are no longer required under the final rule. PM CPMS
measurement data are to be in units of raw instrument output and not necessarily on a concentration
basis in the final rule. The final rule also does provide for the use of a PM CEMS to determine
compliance with the filterable PM emission limit if the source elects to use this approach (see the final
preamble for further discussion).

11.	ESPs vs. fabric filters.

Comment 65: Commenter 17705 has concerns because while ESPs are highly effective control
technologies, they may not be as consistent in its day-to-day performance as fabric filter technology.
According to the commenter, this difference is not a problem at currently permitted PM limits and under
current compliance demonstration requirements (i.e., annual performance testing), but it could be a
significant problem if the EPA retains the currently proposed requirements to establish PM operating
limits, as such operating limits are expected to allow little, if any, operational variability in control
equipment. The commenter doubts that even utilities with EGUs equipped with fabric filters can be
confident they can demonstrate continuous compliance if the PM operating limit requirement is
implemented as proposed by the EPA.

Response to Comment 65: While the rule no longer requires use of PM CEMS and associated
operational limits, the rule retains establishing an operational limit and measuring it using a PM CPMS.
Should the owner or operator be uncomfortable with using a PM CPMS and an operating limit, the final
rule also does provide for the use of a PM CEMS to determine compliance with the filterable PM
emission limit if the source elects to use this approach (see the final preamble for further discussion).
The source can also conduct quarterly performance testing in place of these continuous monitoring
options.

12.	Direct measurement.

Comment 66: Commenter 17747 states that direct monitoring of pollutants rather than a surrogate (PM)
will contribute to a better understanding of the health effects associated with each metal. According to
the commenter, direct measurement for HAP by the EPA is a provision of the CAA Revisions of 1990
and best fit with the requirements and purpose of the law.

Response to Comment 66: Consistent with the CAA, the rule requires monitoring sufficient to assure
compliance with the emissions limits and that the sources will maintain emissions reductions on a
continuous basis. The rule applies continuous emissions monitoring effectively with a focus on the HAP

169


-------
(Hg) of interest and allows for other monitoring in a manner consistent with the CAA. We also believe
that implementing this rule with the required frequent testing, including HAP metals, and continuous
emissions monitoring will provide a significant increase in the amount of directly measured emissions
data over the current database. The rule also requires electronic reporting of monitoring and testing data
directly to the EPA so that we will have these data in hand for supporting subsequent regulatory reviews.

Comment 67: Commenter 17881 states that it makes little sense to have sections 63.10005(d)(1)
through (d)(6), as well as section 63.10005(e), describe the averaging of hourly "concentrations"
obtained using a CMS during an initial 30-day period when the emission standards are always expressed
as emission rates (in units of lb/MMBtu, lb/TBtu, lb/MWh or lb/GWh). Commenter further notes that
section 63.10005(d)(5) currently discusses the use of PM CEMS for demonstrating compliance with the
applicable emission limits in Tables 1 and 2 of the proposed rule but that the reference to the use of PM
CEMS for demonstrating compliance with the emission limits is wholly inappropriate, as the PM CEMS
are to be used to verify compliance with an operating limit (in units of mg/dscm) consistent with Table 4
of the proposed rule, not PM emission limits expressed as lb/MMBtu or lb/MWh (and reckoned on a
different basis, i.e., total PM versus filterable PM).

Response to Comment 67: We have edited the final rule so that the text is consistent with the format of
the required measurements. Note also that measurement of condensable PM is not required in the final
rule and PM CEMS are no longer required in the final rule. The final rule does provide for the use of a
PM CEMS to determine compliance with the filterable PM emission limit if the source elects to use this
approach (see the final preamble for further discussion).

13. Clarification on use of parametric monitoring in lieu of CEMS.

Comment 68: Commenter 17914 requests clarification on the parametric monitoring approach
described on page 25064. The commenter finds only an annual test requirement for the Parametric
Monitoring option. The commenter notes that in the preamble (pages 25029 -31) both initial compliance
and on-going compliance for IGCC or coal or solid oil-derived fuels requirements are discussed and if
an EGU elects to use total PM as a surrogate for non-Hg HAPS, they must use a PM CEMS. The
commenter states that an EGU may:

•	Install PM CEMS and reduce the level of testing regardless of type of control equipment status

•	Demonstrate compliance by testing every month if no controls are installed and no continuous PM

monitoring is done

•	Demonstrate compliance by testing every 2 months if controls are installed and specific control

equipment parameters are monitored with PM CEMS

The commenter states that any EGU can, as an alternate to testing, install PM CEMS. According to the
commenter it is unclear in the body of the proposed rule what testing beyond an annual compliance test
may be required for the parametric monitoring option, and there is no evidence provided by the EPA to
suggest why a parametric monitoring approach would require additional testing beyond that required for
PM CEMS. According to the commenter, it would be expected that a change in coal characteristics,
combustion system operation or AQCS system performance may cause the parametric correlation to PM
emissions to change but it is not clear why a PM CEMS would be immune to this same effect.

According to the commenter, the use of PM CEMS requires use of a quasi-parametric relationship with
filterable particulate since the PM CEMS signal must be correlated to the reference method, for example

170


-------
EPA Method 5 or Method 17. The commenter states that these correlations can change over time and
with varying conditions. Monthly variation of PM emissions vs. system operating parameters requires
additional study to determine if any variation exists that may result in exceedance of the total PM limit.
The commenter states that this study should also include PM CEMS and the potentially variable
relationship of filterable PM to Total PM over time. The commenter recommends the proposed rule be
revised to reduce the testing requirements when using the parametric monitoring to an annual test or less
often when it is proven that PM emissions are < 75% of the MACT limit in line with the final Industrial
boiler MACT (subpart DDDDD) regulations. The commenter further recommends that the text in
section 63.1 0022 explicitly include wet ESP technology in the parametric monitoring options for PM.

Response to Comment 68: Measurement of condensable PM is not required in the final rule. PM
CEMS are no longer required in the final rule. If you use a PM CPMS, you must conduct annual testing
to assess the operating limit (expressed in the raw output of the PM CPMS) established during the
previous test.

Comment 69: Commenter 19033 recommends that the operating requirements for ESP power input, as
documented during performance tests, only be applicable during periods of PM CEMS downtime, so
that it can be demonstrated that the ESP is operating properly during such PM CEMS downtime events.
The commenter states that such a provision would be patterned after the Part 75 requirements that
address demonstration that the APCD is operating properly, so that SO2 substitution values can be
supported during periods of SO2 CEMS downtime.

Response to Comment 69: Parameter monitoring of ESP parameters is not required in the final rule.

Comment 70: Commenter 19121 states that units with PM CEMS should not be required to install bag
leak detectors.

Response to Comment 70: Parameter monitoring of baghouses, including bag leak detectors, is not
required in the final rule.

14. Corrections.

Comment 71: Commenter 18014 states that Table 8 erroneously references "QA Procedure 5" for the
PM CEMS QA/QC requirements. According to the commenter, this reference should be changed to
"Procedure 2."

Response to Comment 71: This reference has been removed in the final rule.

Comment 72: Commenter 19121 states that part 63 Table 4 is setting operating limit averaging periods
of 1 hour for outlet emissions is counter to the 30 boiler operating day averaging methodology.

Response to Comment 72: The final rule requires a 30-boiler operating day rolling average for the PM
CPMS monitoring.

Comment 73: Commenter 17881 states that the PM CEMS should not be subject to the quality
assurance tests required under section 63.10021 (a)(l l)(iv) because filterable PM is not the regulated
pollutant and correlation testing will dictate operating in an abnormal manner for purposes of obtaining
three different PM levels. Commenter notes that this applies also to (a)(16)(vii) and (a)(17)).

171


-------
Response to Comment 73: The final rule does provide for the use of a PM CEMS to determine
compliance with the filterable PM emission limit in the final rule if the source elects to use this approach
(see the final preamble for further discussion). If this option is used, the source must comply with the
QA requirements in PS 11. However, PM CEMS are not required in the final rule. If the source uses the
monitoring as a PM CPMS to demonstrate compliance with an operating limit, then the provisions of PS
11 do not apply, and the applicable QA/QC provisions will be as set forth in the monitoring plan
required in the final rule.

Comment 74: Several commenters (19536, 19537, 19538) state the compliance provisions specify
periodic performance testing in which the surrogate, regulated pollutants, and operating parameters are
monitored for two cases: (1) no PM CEMS with PM controls and (2) no PM CEMS with no PM
controls. The commenters state that if a PM CEMS is used, regardless of whether the units is equipped
with PM controls, no operational or non-Hg metal HAP monitoring is required except during an every 5-
year performance test and that this is inadequate to determine continuous compliance. Further, it does
not provide any testing for metals present as gases or condensables. Thus, state the commenters, HAP
such as selenium, which the EPA admits is frequently present in the gases, would not be measured either
directly with Method 29 or indirectly through a surrogate when PM CEMS is used to determine
compliance. The commenters also state that initial performance compliance provisions are missing from
Table 5 for PM CEMS.

Response to Comment 74: You may elect to comply with an optional operating limit for PM. If you
use this method to demonstrate continuous compliance, you must install a PM CPMS and establish the
operating limit during the initial compliance test for filterable PM, total non-Hg HAP metals, or
individual non-Hg HAP metals (or HAP metals inclusive of mercury for liquid oil-fired units). The
operating limit for demonstrating continuous compliance shall be based on the highest 1-hour average
measured during the most recent performance test. If you use a PM CPMS and associated operating
limit, you must conduct the applicable Method 5 or Method 29 test once annually and re-establish the
operating limit during each performance test. A PM CPMS does not need to meet the requirements for a
PM CEMS under PS 11. The final rule also does provide for the use of a PM CEMS to determine
compliance with the filterable PM emission limit if the source elects to use this approach (see the final
preamble for further discussion). In that case, the PM CEMS is used as the direct method of compliance
and no additional testing is required other than tests that are required as part of the QA requirements in
PS 11.

15. Five-year test requirement.

Comment 75: Commenter 17798 states that stack testing once every 5 years to corroborate
CEMS monitoring is a very long time period to rely on CEMS filterable PM data which may or may not
relate to actual metals emissions. Therefore, the commenter feels this monitoring approach is overly
complex, requires expensive CEMS monitoring, and may not demonstrate real metals emission levels
for up to 5 years. The commenter requests that the EPA consider the following modifications: With the
CEMS monitoring option, require stack testing every 2 years instead of 5 years to establish compliance
with metal emission limits relative to filterable PM emissions. The commenter states that using a CEMS
approach is premised on the EPA's ability to establish a relationship between filterable PM and metals
emissions on a sector-wide basis and sources with particular control equipment may require adjustments
to this method to account for wet conditions from wet scrubbers. The commenter asserts that under a
CEMS monitoring approach the EPA should eliminate any requirement for testing and setting of
pollution control equipment operating parameters.

172


-------
Response to Comment 75: The comment is moot, as the rule does not require use of PM CEMS; PM
CPMS are an alternative and annual testing is required to reassess the operating parameter value. For
those owners or operators who choose to use PM CEMS as an alternative, no additional operating
parameter value monitoring or limit is necessary. Furthermore, in that case, the PM CEMS is used as the
direct method of compliance and no additional testing is required other than tests that are required as
part of the QA requirements in PS 11.

Comment 76: Commenter 17800 asserts that the EPA has not explained why there should be an
independent filterable PM limitation that changes every 5 years. According to the commenter, although
it is reasonable to retest for compliance every 5 years because of the innate variability of unit operation
resetting emission limitation is not.

Response to Comment 76: The comment is moot, as the rule does not require the use of PM CEMS and
PM emissions testing every 5 years. Where a source uses a PM CPMS as part of its monitoring
approach, annual testing is required to reassess the operating parameter value.

16.	PM as surrogate Method 202.

Comment 77: Commenter 19114 states that using total PM as a surrogate has numerous technical
challenges that demonstrating continuous compliance using a filterable PM limit does not. The
commenter states that filterable PM can be measured continuously through a PM CEMS monitor.
According to the commenter, the variability of condensable PM in the flue gas is enormous and the test
methods for condensable PM are still incapable of accurately measuring the condensate in a replicable
fashion routinely. The commenter states that the study that the commenter conducted, in conjunction
with EPRI, showed that the Method 202 may not be accurate in stacks with FGD. The commenter states
that more study is required to understand the limitations with the measurement of condensables and to
construct a test method that will be accurate and repeatable for in-stack measurements.

Response to Comment 77: While the agency disagrees with the suggestion that Method 202 is
"incapable of accurately measuring the condensate in a replicable fashion routinely," the comment is
moot, as the final rule does not contain a total PM emissions limit.

17.	Miscellaneous.

Comment 78: Commenter 17800 states that under section 63.10010(g)(3) the EPA is requiring a PM
CEMS to "complete a minimum of one cycle of operation (sampling, analyzing, and data recording) for
each successive 15-minute period." According to the commenter, depending on the PM CEMS used and
the level of particulate emitted this may not be possible. For example, states the commenter, a system
that uses a filter tape (dichotomous sampler) to measure filterable PM where there is very low filterable
PM levels emitted (similar to the proposed PM standard) may not be able to collect enough sample to
adequately measure these emissions in this 15 minute timeframe. The commenter states that the EPA
should allow some flexibility in this requirement to allow for monitoring extremely low levels of
filterable PM emissions.

Response to Comment 78: Measurement of condensable PM is not required in the final rule. PM
CEMS are not required in the final rule.

Comment 79: Commenter 17752 questions, with respect to PS 11, whether it is possible to create or
measure two PM levels between zero and the levels anticipated in the rule.

173


-------
Response to Comment 79: The rule now includes an option for using PM CPMS, whose use should
alleviate the commenter's concerns, as well as maintains the option for using PM CEMS. Note that other
compliance options exist should an EGU owner or operator choose not to use PM CPMS or PM CEMS.

Comment 80: Commenter 17752 suggests that PM CEMS could be used as an "indicator of
compliance" for an "appropriate" filterable PM limit, to identify when investigation and corrective
action are warranted.

Response to Comment 80: The comment is moot, for while the rule maintains the use of PM CEMS as
a compliance demonstration option, the final rule also allows the use of PM CPMS, which involves
establishing and maintaining a site-specific operating limit as an indicator of compliance, as another
compliance demonstration option.

Comment 81: Commenters 17724 and 17876 state that the CEMS the facility installed in preparation to
CAMR have significant reliability and operational issues (Hg, PM, HC1). Commenters 17724 and 17876
state that the EPA has left the long-term operational problems such as calibration gases to industry and
there are not accurate and reliable monitoring methodologies for demonstrating. Commenters 17724 and
17876 state the EPA purports to provide compliance flexibility while in reality there is very little
flexibility in light of the problematic and unproven nature of these monitoring technologies.

Commenter 17736 states the EPA cannot rely on unproven HC1 CEMS, that HC1 CEMS are not
commercially available to measure HC1 emissions from coal-fired EGUs, and no HC1 CEMS were used
to collect the data the EPA used to establish the HC1 standard.

Response to Comment 81: The agency disagrees with the commenters. As mentioned elsewhere, the
agency finds that the operation and maintenance issues for the CEMS mentioned are no different than
for other CEMS now in wide use and acceptance by the industry. The agency is aware that the
calibration gas issue is to be rectified well in advance of the rule's compliance date. The agency notes
that the rule is quite flexible with respect to compliance demonstration, containing numerous choices for
compliance, including the use of emissions testing alternatives for those EGU owners or operators who
remain concerned over use of CEMS or PM CPMS. The agency notes that FTIR CEMS exist now and
can be used to measure HC1 emissions continuously, that the HC1 emissions limit was developed from
emissions testing and has been adjusted to be appropriate for measurement with HC1 CEMS, and that
emissions testing options to demonstrate compliance exist for those EGU owners or operators who
choose not to use CEMS.

174


-------
5A07b - Testing/Monitoring: Application of multi-metals CEMS
Commenters: 17283, 17747, 19536, 19537, 19538
1. In favor of multi-metals CEMS.

Comment 1: Commenter 17283 recommends that multi-metal CEMS should be an allowed alternative
for demonstrating compliance with the EPA proposed metals emissions limits. The commenter states
that this recommendation is based on the proven performance and commercial availability of multi-
metal CEMS, the fact that multi-metal CEMS represent substantially enhanced monitoring and PM is
not an appropriate surrogate for HAP metals emissions in an increasingly complex energy extraction
process.

Response to Comment 1: In the final rule, facilities would be allowed to petition the Administrator
under section 63.8(f) of subpart A of part 63for an alternative to use of multi-metal CEMS at a specific
site in lieu of required monitoring in the final rule. Also see responses to comments under Comment
Code 4F01 for further discussion of relationship of PM and non-Hg metal HAP.

Comment 2: Commenter 17747 states that multi-metals CEMS represent the highest level of
monitoring for these sources (i.e., directly monitoring the HAP pollutant of concern on a continuous
basis).

Response to Comment 2: Short term multi-metal CEMS demonstrations have historically shown, with
appropriate QA/QC, that the data are accurate and reliable. Longer term operational information would
be needed to support a proposal of performance specifications. We agree with the commenter that data
from multi-metal CEMS is a direct measurement of metals and not a surrogate measurement.

Comment 3: Commenter 17747 asks that the EPA incorporate language in the final rule expressly
allowing the use multi-metals CEMS once a multi-metals performance specification has been
promulgated. According to the commenter, the incorporation of this type language would give source
operators some assurance that monitoring with a multi-metals CEMS would be acceptable to the EPA,
and it is also likely to encourage the use of multi-metal CEMS on sources, which is beneficial to the
EPA's understanding of the health effects associated with metal HAP. Finally, states the commenter,
multi-metal CEMS would provide source operators with more feedback on control of metals and may
allow them to optimize operations to minimize HAP metal emissions. The commenter provided
information about the capabilities of their proprietary testing technology.

Response to Comment 3: We may in the future propose a multi-metal performance specification and
QA/QC requirements but we have no immediate plans to do so because we lack long term operational
information and the resources to support a proposal. The final rule does reiterate the ability of a source
to petition the Administrator under section 63.8(f) of subpart A of part 63for an alternative to use multi-
metal CEMS at a specific site in lieu of required monitoring in the final rule. The EPA does have a draft
method on its website at www.epa.gov/ttn/emc that could be the basis of a petition to the Administrator
for alternative monitoring. We agree that multi-metal CEMS could possibly provide source operators
with more feedback on control of metals and may allow them to optimize operations to minimize HAP
metal emissions.

Comment 4: Commenter 17283 states that direct monitoring of all phases of all HAP metals is an
enhancement over the monitoring of a surrogate (PM) for some urban HAP metals. According to the

175


-------
commenter, periodic testing does not provide reasonable assurance of control/prevention nor does
monitoring PM provide reasonable assurance of urban HAP metal control/prevention, and multi-metals
CEMS is commercially available and accepted by the EPA. Thus, states the commenter, use of PM as a
surrogate for HAP metals monitoring is no longer needed.

Response to Comment 4: We believe that the final rule does provide a reasonable assurance of
compliance with the non-Hg metals limitation and the monitoring and testing that we are requiring are
consistent with numerous EPA rulemakings for comparable emission sources. We are providing for
monitoring continuous compliance with specific standards through the use of an applicable CEMS, or a
sorbent trap for Hg, or a PM CPMS for non-Hg metals or PM. Should a source owner or operator elect
not to use CEMS or the other instrumental methods, performance testing is required.

2. Individual metals.

Comment 5: Commenter 17283 states that monitoring only the vapor phase of Hg does not provide
reasonable assurance of control/prevention under all conditions that are now to include SSM events. The
commenter states that this is particularly the case when there is a proven and approved technology
available that measures all phases of Hg. The commenter recommends the use of multi-metal CEMS as
an alternative to Hg CEMS.

Comment 6: Commenter 17283 states that selenium does not meet two of the three court-defined
criteria which must be met for PM to be a surrogate for HAP metals: ".. HAP metals are invariably
present in cement kiln PM..." (subsection 3.2.1); and ".. PM control technology indiscriminately
captures HAP metals along with other particulates." (subsection 3.2.2.) According to the commenter, the
addition of a condensable fraction to the definition of PM only complicates this for other HAP metals.

Response to Comments 5 and 6: Note that the final rule no longer applies a numerical emissions limit
during startup and shutdown much reducing concerns about limited measurement of particulate Hg. The
EPA disagrees that selenium does not meet two of the criteria which must be met for PM to be a
surrogate. Selenium is a metalloid that sits just below sulfur on the periodic table and is, chemically,
very similar to sulfur. In the high temperature combustion environment, selenium is likely to be present
as gas phase Se02 (as, similarly, sulfur is likely to be present as gaseous S02). Much like S02, Se02 is a
weak acid gas. The ash from western subbituminous and lignite coals contains natural alkalinity (in the
form of Ca or Na compounds). The alkaline compounds in the fly ash effectively neutralize the Se02
acid gas, forming a particulate that is easily removed in the PM control device. Eastern bituminous coals
typically contain insufficient free Ca to completely neutralize the Se02 and the much increased levels of
S02 in that flue gas. However, because Se02 behaves very similarly to its sulfur analog, S02, it can be
expected to also be removed effectively in standard FGD technologies (wet scrubbers, dry scrubbers,
DSI, etc.). Therefore, selenium will either fall in to the category of "non-Hg metal HAP" and be
effectively removed in a PM control device, or it will fall into the category of "acid gas HAP" as
gaseous Se02 and be effectively removed using FGD technologies. We specifically reviewed the
Method 29 data from the utility boiler ICR where we had measured particulate emissions, selenium
emissions and selenium in the coal. In almost 90 percent of the facilities less than half of the estimated
selenium was emitted. In the remaining facilities, we reviewed the location where selenium was
collected in the Method 29 sampling train and found measureable amounts of selenium on the quartz
filter. While we do not know the amount of selenium that was in the flue gas prior to any emissions
control, we conclude that selenium was available in particulate form after emissions controls and was
likely removed by the particulate and/or acid gas controls.

176


-------
3. Concerns about use of PM as a surrogate.

Comment 7: Commenter 17283 states that reducing HAP metal concentrations from their current levels
in feed and fuel to zero would essentially reduce HAP metals to zero in the emissions (reducing HAP
metals concentrations by many orders of magnitude) while having essentially no impact on PM
emissions. According to the commenter, processes and additives may increase PM emissions without
increasing HAP metal emissions, such as might be the case of scrubber solution bypassing demisters, or
they may increase HAP metal emissions without increasing PM, such as might be the case if trace HAP
metal concentrations increase in an additive or other feed material, or where an additive is injected into
the process. The commenter states that without the direct monitoring of HAP metals, there will be no
way to determine if the HAP metals are changing.

Response to Comment 7: While modifying the feed and fuel such that the HAP metal concentrations
are zero would achieve essentially zero emissions, the EPA knows of no techniques which could achieve
this end without transferring the emissions to another source. Also see responses to comments under
Comment Code 4F01 for further discussion of relationship of PM and HAP metals.

Comment 8: Commenter 17283 states that Method 29 is costly, dangerous, creates hazardous waste and
is difficult to obtain accurate and reliable results at the low concentration expected with contemporary
controls. The commenter states that in effect, it appears that the EPA is using PM as an indicator or
parameter to monitor in much the same way they use plant operating parameters in CPMS. According to
the commenter, as long as PM, fuel, and all control parameters remain relatively constant between
Method 29 measurements, one might be able to assume that HAP metals emissions have not changed
dramatically since the last Method measurement, but it would be far less costly, far more informative
and protective as well as more useful for plant operation if a multi-metals CEMS were used to measure
HAP metals emissions directly and continuously.

Response to Comment 8: The EPA disagrees with the commenter's opinion about EPA Method 29. We
have found the method to provide reliable, low level, repeatable results when properly conducted in the
field. The cost of using this method is actually much more economical, per analyte than many other test
methods that the EPA employs to measure emissions.

Comment 9: Several commenters (19536, 19537, 19538) state that total PM is not an appropriate
surrogate for non-Hg metal HAP and those HAP can be accurately measured by CEMS. According to
the commenter, if the EPA retains total PM as a surrogate, a PM CEMS should be required, not optional,
to determine compliance. The commenter states that PM CEMS have been required in consent decrees
and PSD permits to determine compliance and are in wide use at EGUs.

Response to Comment 9: The final rule uses a filterable PM surrogate limit for non-Hg metal HAP,
with the required compliance testing using a manual PM method. The EPA also established an alternate
equivalent standard for non-Hg metal HAPs, but the on-going monitoring with these metals is
accomplished with a PM CPMS for an operational limit or frequent testing with a metals manual
method. Also see responses to comments in 4F01 of this document for further discussion of relationship
of PM and HAP metals. Furthermore, the final rule also does provide for the use of a PM CEMS to
determine compliance with the filterable PM emission limit if the source elects to use this approach (see
the final preamble for further discussion). In that case, the PM CEMS is used as the direct method of
compliance and no additional testing is required other than tests that are required as part of the QA
requirements in PS 11.

177


-------
5A08 - Testing/Monitoring: Application of SO2 CEMS

Commenters: 17191, 17383, 17621, 17677, 17722, 17725, 17728, 17730, 17752, 17758, 17775, 17790,
17800, 17820, 17821, 17868, 17873, 17881, 17886, 17902, 17909, 18014, 18037, 18428, 18498, 18539,
19120, 19536, 19537, 19538, 18023

1. Allow existing IGCC units to use S02 CEMS option.

Comment 1: Commenter 17191 believes it is appropriate for the EPA to include the S02 monitoring
option in Table 2, part 3b as an alternative to monitoring HC1. The commenter notes in response to the
EPA statements in the preamble regarding a lack of data on S02 monitoring for existing IGCCs, that
SO2 CEMS monitoring data for its IGCC unit are routinely submitted electronically to the EPA and the
EPA has ready access to the CEMS data as they are publically accessible and have been used previously
in the rulemaking for the Transport Rule (aka Cross-State Air Pollution Rule). The commenter stresses
the importance of the S02 monitoring as an option, given the current lack of a PS specific to HC1
CEMS, as described in the proposed rule preamble. The commenter believes that it is in the best interest
of it cooperative members to be able to rely on existing S02 monitors for acid gas compliance rather
than incurring the cost of installing HC1 monitors that have little or no long-term demonstrated "real
world" reliability. The commenter requests that the S02 CEMS monitoring option be included for the
existing IGCCs as a matter of equity and fairness. As these data are readily available to the EPA and
interested public, there is no basis for the EPA's preamble justification for not including the option.
While the commenter specifically references their IGCC unit, they do note that it is one of only two
IGCC EGUs currently operating that are included in the existing IGCC category established by the
proposed regulation.

Commenter 17191 requests that section 63.9991 be rewritten to eliminate the pre-requisite of using a
wet or dry FGD technology to qualify for the alternate S02 CEMS limit. The commenter notes that their
IGCC system uses a sulfur removal system upstream of the combustion of the syngas; the removed
sulfur is captured and sold as molten sulfur for reuse. According to the commenter, as the sulfur is
removed prior to combustion no FGD technology is required for IGCC emissions. The commenter
believes this Clean Coal Technology should not be penalized (prevented from opting to use S02
monitors) because it uses an upstream technology for sulfur removal, eliminating the need to treat the
flue gas for S02 removal.

The commenter attempted to find the provisions in the regulation that need to be amended so that
existing IGCC units can rely on the option of S02 CEMS use. The commenter requests that the EPA
amend other sections of the regulation, as necessary, which may have been overlooked or that may be
subject to revision before final rule issuance that would prohibit existing IGCC S02 CEM use.

The commenter suggests the following modifications to section 63.9991:

"(a)(l)(i) You man not use the alternate SO 2 limit if your coal-fired EGU does not have a
system for pre-combustion sulfur removal or a system using wet or dry flue gas
desulfurization technology installed on the unit. " (Emphasis reflects proposed inserted
change).

"(a)(1)(H) You may not use the alternate SO 2 limit if your oil-fired EGU does not have a
system for pre-combustion sulfur removal or a system using wet or dry flue gas

178


-------
desulfurization technology installed on the unit. " (Emphasis reflects proposed inserted
change).

"(a)(I)(Hi) You must operate the pre-combustion sulfur removal system, or the wet or
dry flue gas de sulfur ization technology installed on the unit at all times in order to
qualify to use the alternatedS02limit. " (Emphasis reflects proposed inserted change).

The commenter also requests that section 63.10000(c)(1) be amended, in part, to read:

"As another alternative to HCl CEMS, you may demonstrate initial and continuous
compliance through use of a certified sulfur dioxide (SO 2) CEMS, provided the unit has a
system for pre-combustion sulfur removal or a system using wet or dry flue gas
de sulfur ization technology. " (Emphasis reflects proposed inserted change).

Comment 2: Commenter 17758 suggests SO2 CEMS should be allowed to be used as a surrogate for
HCl for IGCC units since FGD is not needed for those units and HCl CEMS are not a proven
compliance monitoring technology. The commenter believes such details need to be clearly defined in
the final rule.

Response to Comments 1-2: The EPA disagrees with the commenters' suggestions First, the premise
upon which the rule allows for SO2 monitoring in lieu of HCl monitoring of the exhaust of a wet or dry
FGD unit is that the FGD preferentially removes HCl over S02. That means that S02 control is a certain
indicator of similar or better HCl control when the control measure is a wet or dry FGD. We are not
aware that other sulfur control measures including pre-control sulfur removal can be related to similar
HCl emissions reduction. Further, the rulemaking record does not have any SO2 data from existing
IGCC units to correlate with HCl emissions. The S02 data pne commenter references are not data
collected as part of establishing the HCl standards under this rule. As noted by the commenter, the unit
in question appears not to use a wet or dry FGD, which is a prerequisite for using S02 as an indicator of
HCl control. The preamble to the proposed rule fully explains the rationale for this limitation.

2. SO2 CEMS certification.

Comment 3: Commenter 17677 states that section 63.10010(e) creates some confusion about
certification of S02 CEMS. The commenter believes the proposed rule should simply allow CEMS
certified under 40 CFR 75 or 40 CFR 60 to be acceptable.

Response to Comment 3: The EPA disagrees as the specific provisions in section 63.10010(e) add
specific requirements to the general part 60 and part 75 requirements. Note that the EPA believes part of
the commenter's confusion results from a typographical error in cross referencing paragraph (g) of the
section. All of those cross references should be to paragraph (e), not (g), and are corrected in the final
rule.

Comment 4: Commenter 17402 objects to the linearity test requirement for SO2 monitoring. The
commenter states that section 63.10010(e)(6)(ii) of the proposed regulations states that one "must
perform the linearity check test required in Appendix A to part 75 on the SO2 CEMS whether or not it
has a span of 30 ppm or less." According to the commenter, this requirement ignores the EPA's previous
acknowledgement that a linearity check "begins to lose its significance" at span values less than or equal
to 30 ppm. The commenter states that in the preamble to the proposed 1998 revisions to 40 CFR Part 75,
the EPA acknowledged that span at these low values loses its significance. The commenter believes the

179


-------
proposed requirements should be replaced with the Part 75 exemption. According to the commenter part
75 requires EGUs to ensure that the analyzer span is set to obtain accurate and representative data. Part
75 also requires the owner or operator of an EGU to conduct an annual analyzer span and range
evaluation to ensure that the majority of the analyzer readings are within 20 to 80% of span. According
to the commenter, coupled with these requirements, the three linearity gas concentrations are more than
sufficient to determine that the analyzer is linear. The commenter states that the proposed linearity
requirement will add significant costs.

Response to Comment 4: The final rule has been amended to remove the fourth gas nominally near the
emission standard level. The EPA disagrees that a linearity check is unnecessary to ensure quality
assurance of the SO2 CEMs for compliance at emission standard levels.

Comment 5: Commenter 17758 states that it is confusing why, despite using continuous S02 monitors
successfully for more than 20 years, the EPA has proposed additional QA requirements. The commenter
states that in proposed section 63.10010(e)(6) the EPA has added several problematic additional QA
requirements for SO2 CEMS that are not currently specified in Appendices A or B of 40 CFR part 75.

The commenter notes the following:

•	Section 63.10010(e)(6)(i) - According to the commenter, the proposed Utility MACT rule would
require the SO2 CEMS to pass a 7-day calibration error test for units with spans less than or
equal to 50 ppm and it is unclear whether the specifications in Part 75 or PS 2 are applicable.
According to the commenter, under Part 75 requirements, the 7-day calibration error
specification is a difference of less than or equal to 2.5 percent of span or ±5 ppm; using the Part
75 specifications, current SO2 CEMS should be able to easily meet the alternative ±5 ppm
requirement. The commenter states that if the PS 2 specifications are to be applied, then the
specification is restricted only to the drift requirement of 2.5 percent of span, and this will make
passing the 7-day calibration error test significantly more burdensome. According to the
commenter regardless of which specification is used, neither will improve the overall quality or
accuracy of the collected data, since these are only implemented for initial certification or
recertification events; in other words, there is little a utility can do to upgrade its SO2 CEMS to
meet this requirement.

•	Section 63.10010(e)(6)(ii) - According to the commenter, the addition of the linearity test will be
an additional QA requirement for many existing systems that have SO2 CEMS installed
downstream of a wet or dry scrubber, will add significant cost to update software to integrate the
new procedure, and potential costs to add the necessary hardware to existing systems to
accommodate the new calibration gas cylinders, and will increase calibration gas costs, not only
in the capital cost of purchasing the additional calibration gases but also in monthly demurrage
fees.

•	Section 63.10010(e)(6)(iii) - According to the commenter, this provision may require utilities to
add a fourth calibration gas to the linearity sequence in order to have a calibration gas
"nominally at a concentration level equivalent to the applicable emission limit." The commenter
states that if a utility is required to include a fourth calibration gas level to the linearity check
procedure, an additional cost in terms of hardware and software upgrades to integrate the fourth
linearity calibration gas into the calibration system will be incurred by the utility. According to
the commenter, this requirement is unnecessary and will not improve the quality of SO2 data
being collected. The commenter states that current guidelines in 40 CFR Part 75 ensure that the
majority of emission measurements made by an S02 CEMS fall within a certain percentage of
the monitor's calibrated span and that users are required to evaluate the span of the SO2 CEMS

180


-------
on annual basis, which has proved sufficient in maintaining the overall integrity and accuracy of
the S02 emissions being reported. At a minimum, states the commenter, the EPA should quantify
the term "nominally" (e.g., a calibration gas within ±20 percent of the equivalent concentration
level).

Response to Comment 5: The final rule will be amended to remove the 7-day calibration error test for
units with spans less than or equal to 50 ppm and remove the fourth calibration gas nominally near the
standard. The EPA disagrees that a linearity check is unnecessary to ensure quality assurance of the SO2
CEMs for compliance at emission standard levels and will retain that requirement. In addition, sources
may choose to comply with HC1 CEMS or periodic HC1 testing in lieu of updating their SO2 CEMS
system to check linearity quarterly.

3. Revisions to FGD applicability.

Comment 6: Commenters 17728 and 17775 support the EPA's inclusion of an option for use of an S02
CEMS to comply with a surrogate limit for SO2; however, they believe several adjustments are needed
to make this a reasonable option. The commenters state that to use the option, wet or dry FGD
technology must be operated "at all times." The commenters state the EPA should clarify that this
requirement is not intended to disqualify EGUs that experience S02 control device malfunctions or that
must bypass controls during the initial portions of startups or to perform maintenance (which generally
require bypass of the entire control unit). The commenter states that for units without a bypass stack, any
resulting emissions would be monitored in the main stack with the SO2 CEMS; for units with a bypass
stacks, temporary bypass might be necessary during a malfunction or to perform necessary maintenance
to minimize periods of malfunction. According to the commenter, either way, as long as the SO2
emissions are accounted for those emissions will reflect the potential for higher HC1 as well, and any
unit complying with the 30-day rolling average SO2 limit will achieve the necessary control for HC1
(i.e., the acid gas HAP). Thus, the commenters believe the EPA should clarify that the "at all times"
requirement does not apply to periods of malfunction, or to the temporary use of a bypass stack during
periods of malfunction or maintenance, provided S02 emissions are accounted for and the applicable
standard is met.

Commenter 17752 states the EPA must clarify in section 63.9991 (a)( 1 )(iii) that "at all times" is intended
to disqualify EGUs that operate SO2 controls intermittently, and not to disqualify EGUs that experience
SO2 control device malfunctions or that must operate without control devices during periods of EGU
startup and shutdown.

Commenter 17714 states that the EPA should clarify that operation of FGD technology is only required
for periods when the affected unit is operating. Commenter 17714 states the requirement to operate the
APCD "at all times" should include provisions to follow manufacturer's recommendations regarding
when APCD operation is to be initiated and/or curtailed during startup/shutdown of the unit.

Commenter 17885 states that for the alternative SO2 limit, the EPA should qualify that that "at all times"
is not intended to disqualify units that experience control malfunctions or that bypass during
startup/shutdown.

Comment 7: Commenters 18539 and 19120 note that section 63.9991 (a)(l)(iii) indicates that the FGD
must be operated at all times in order to qualify to use the alternate SO2 limit to demonstrate compliance
with the acid gas HAP emission limitation. The commenters believe that if a unit can demonstrate
compliance with the applicable SO2 limit based on monitored emissions from the bypass and the

181


-------
scrubbed stack, a source should be allowed to exhaust to the bypass stack, at least, on a limited basis, as
many of these stacks are already equipped with S02 CEMS. One commenter notes that exhausting to the
bypass stack is a necessary option in many cases, and provides four examples.

Comment 8: Several commenters (17800, 17868, 18428) believe the EPA should make clear that this
requirement in section 63.9991 (a)(l)(iii) is intended to disqualify EGUs that operate SO2 controls
intermittently, and not to disqualify EGUs that experience SO2 control device malfunctions or that must
turn off controls to perform maintenance. The commenters note the higher SO2 recorded by the CEMS
during such periods will reflect the potential for higher HC1 as well, and as long as the SO2 CEMS meets
the surrogate standard for HC1 these FGD off periods should not disqualify an EGU from using an SO2
as a surrogate. The commenters suggest the EPA make clear that the existence of a bypass stack does
not disqualify an EGU from complying with the standard.

Comment 9: Commenter 17886 supports the option to use SO2 CEMS to comply with a surrogate SO2
limit; however, the commenter believes use of a bypass stack during startups or malfunctions as part of
good engineering and maintenance should not disqualify an EGU from this option. The commenter
suggests the EPA could require sources to account for these periods as provided in 40 CFR section
75.16(c)(3), which requires use of a maximum potential value for each hour when the bypass stack is in
use.

Comment 10: Commenter 18037 does not support the requirement that S02 controls must be operated
at all times if the SO2 surrogate is selected. The commenter believes that so long as a facility complies
with S02 emissions limits, operators should have the flexibility to operate S02 controls in any mode to
meet the compliance limit. The commenter recommends that the EPA remove the continuous control
requirements regarding S02 from the proposed rule. The commenter believes this additional requirement
is superfluous if SO2 is a reasonable surrogate, and if facilities monitor SO2 continuously using reliable
CEMS. The commenter believes an EGU that demonstrates compliance with S02 limits, but whose S02
controls are not in continuous operation, should not be considered in violation of the rule.

Comment 11: Commenter 17909 suggests the EPA should allow a 12-month rolling SO2 limit and
clarify that FGD bypass is allowed during times of FGD forced outage. The commenter believes these
changes would allow very limited continued operation through the bypass during upset conditions.

Comment 12: Commenter 18023 believes that for PC units, the EPA should allow a scrubbed unit to
bypass for a short time and allow the source to use the SO2 monitors in the bypass stack. As written, the
rule appears to require a unit with the ability to bypass to install an HC1 CEMS or otherwise monitor
HC1 on the bypass stack. If a unit that bypasses controls for a short period of time is capable of meeting
the MACT S02 limit, then scrubber bypass should be allowed. The commenter believes there is no
environmental justification for penalizing these units.

Response to Comments 6-12: In the final rule, the EPA has clarified the "at all times" language. The
intent is that the FGD be operated during all boiler operations and not operated intermittently,
seasonally, or on some other non-fulltime basis. Thus, this alternate limit is allowed even if bypass may
occur during malfunction, but sources may be subject to penalties or other action if the malfunction
causes the source to not comply with the requirements of the standards. We have established work
practice standards for periods of startup and shutdown, as those terms are defined in the final rule, and
the use of the FGD system must be in accordance with the work practice standards during those periods
(i.e., the system must be engaged before coal or residual oil is burned in the boiler unit).

182


-------
4. SO2 as surrogate.

Comment 13: Commenter 17730 agrees with the proposal by the EPA to use SO2 as a surrogate as one
of the options for measuring the acid gases category of HAP. The commenter also appreciates the
proposals reliance on the SO2 CEMS as the basis of ongoing compliance with the requirements. The
commenter believes SO2 emissions were well correlated with the acid gases in the analysis of the EPA
ICR test data. SO2 CEMS are used by the commenter to measure the emissions of SO2, and the
commenter believes they produce accurate emission estimates.

Comment 14: Commenter 17758 believes there is no basis for testing of the surrogate SO2 at a unit that
is complying with the HC1 standard or for HC1 emissions testing at a unit with HC1 CEMS. For example,
states the commenter, proposed section 63.10006(h) requires EGUs "without SO2 CEMS but with
installed systems that use wet or dry flue gas desulfurization technology" to conduct "all applicable
performance tests for SO2 and HC1 emissions" at least every year and to "conduct SO2 emissions
testing" at least every month. The commenter suggests the EPA make clear that these provisions do not
apply to EGUs with HC1 CEMS.

Comment 15: Commenter 17383 supports the use of SO2 CEMS as a surrogate monitoring technology
for HAP acid gases.

Comment 16: Several commenters (19536, 19537, 19538) endorses SO2 CEMS methods to determine
compliance, and believes they should be required, rather than presented as an option.

Comment 17: Commenter 17621 believes given the use of pulsed fluorescence analyzers, it is
reasonable to expect that equipment will be available to measure SO2 in the flue gas at the proposed
alternative MACT limits for new and existing coal-fired EGUs (approximately 0.04 lb/MMBtu and 0.2
lb/MMBtu, respectively), even accounting for the dilution extractive sampling systems. The commenter
notes that at the emission levels typically found in power plants, the impact of sample line losses has not
been an issue and operators have minimal problems meeting the 7.5% relative accuracy; however, when
trying to measure very low concentrations, sample line losses may make the RA criterion more difficult
to meet.

Comment 18: Commenter 17725 believes there is no value in performing Cylinder Gas Audit (CGA)
tests quarterly on SO2 analyzers with span values less than 30 ppm SO2 that are currently certified to
report under 40 CFR part 75 rules. The commenter recommends the EPA add a subsection to section
63.10010(e) that clearly states that 40 CFR part 75 data substitution procedures and bias adjustment
factors are not to be used to calculate the 30 boiler operating day average SO2 emission rate.

Comment 19: Commenter 17886 recommends the EPA clarify that provisions in section 63.10006(k)
do not apply to EGUs with SO2 CEMS that are used to meet requirements pertaining to the alternative
acid gas limit.

Comment 20: Commenters 17775 and 17868 recommend the EPA clarify the subsequent performance
testing requirements for units without HC1 CEMS in proposed section 63.10006(h) and (i). The
commenters suggest the EPA make clear that the provisions for EGUs "without HC1 CEMS" do not
apply to EGUs with SO2 CEMS, and must remove the initial testing requirement for HC1. The
commenters believe there is no basis for testing of HC1 at a unit that is complying with the surrogate
SO2 limit and proposed Tables 1 and 2 clearly provide sources the option of meeting an HC1 or an SO2
standard. Commenter 17775 also believes the EPA does not explain what it means by EGUs "without

183


-------
SO2 CEMS" or what significance those SO2 CEMS have for EGUs not choosing to comply with the
surrogate S02 limit. The commenter suggests that virtually all coal-fired EGUs covered by this proposed
rule already have SO2 CEMS installed as a result of other regulatory programs, like the Acid Rain
Program.

Commenter 17775 notes proposed section 63.10006(j) requires EGUs "without HC1 CEMS but with
HC1 emissions controls" to test for HC1 at least every month, and proposed section 63.10006(k) requires
EGUs "without HC1 CEMS and without HC1 emissions controls" to test for HC1 at least every other
month. The commenter notes there is nothing in the proposal to exempt EGUs with SO2 CEMS, but not
HC1 CEMS, from proposed requirements applicable to EGUs "without HC1 CEMS." The commenter
also notes proposed section 63.10005(a) also specifically requires HC1 testing initially for any EGU that
uses "a continuous monitoring system that measures a surrogate for a pollutant (e.g., an S02 monitor)."

Comment 21: Commenter 17881 notes for those units with an SO2 CEMS, the concept of an additional
performance test every 5 years makes little sense, as such units are required to determine a new 30-day
rolling average emission rate for every operating day following the initial 30-day compliance test.

Response to Comments 13-21: The EPA appreciates the support for the use of SO2 as an alternate
equivalent standard and reliance on an S02 CEMS. The EPA also agrees that sections 63.10005
and 63.10006 need to be clarified to be consistent with Table 5 - if an HC1 CEMS is used, the SO2
testing requirements do not apply, and vice versa.

5. Part 75 concerns.

Comment 22: Commenter 17722 supports inclusion of 40 CFR part 75 monitoring provisions for SO2
CEMS; however, the commenter does not support the addition of new part 75 requirements. The
commenter cites section 63.10010(e)(6), which requires additional provisions not currently needed for
an S02 CEMS under part 75. The commenter notes that as a comprehensive monitoring rule, part 75
provides certified data within the means of the technology. The commenter notes these additional
monitoring requirements were exempted from certain monitor ranges because the monitoring technology
is unable to perform the EPA methods either due to monitor limitations or due to protocol limitations.
The commenter believes since current part 75 S02 collected data is accepted by the EPA as credible
evidence of compliance with Acid Rain provisions, it should also be acceptable to the EPA for
demonstration of compliance with the MACT standard without creating additional requirements as listed
in section 63.10010(e)(6).

Comment 23: Several commenters (17725, 18014, 18498) suggest that while the rule allows the use of
Part 75 SO2 CEMS, it includes additional QA/QC requirements that will be problematic. The
commenters reference section 63.10010(e)(6)(i), which states the operator "must perform the 7-day
calibration error test required in Appendix A to part 75 on the SO2 CEMS whether or not it has a span of
50 ppm or less." The commenters do not understand what this requirement will accomplish as the
majority of part 75 affected sources has completed initial certification years ago and has been collecting
"quality-assured" data for years.

Comment 24: Commenters 17790 and 17820 have concerns with the linearity and 7-day calibration
error test requirements contained in the proposal that are not required under part 75. Commenter 17820
believes requiring these tests will complicate compliance for EGUs currently complying with part 75
and without providing any added accuracy to the measurement. Commenter 17790 suggests these
requirements be removed for companies that plan to use their part 75 SO2 CEMS. The commenter notes

184


-------
CEMS with a span less than 50 ppm are exempt from the 7-day calibration error and CEMS with a span
less than 30 ppm are exempt from the quarterly linearity testing and that CEMS are meeting the 7-day
calibration error specification on a daily basis during their daily calibration. The commenter also notes
the EPA also determined that for CEMS with spans less than 30 ppm, the linearity testing was not
significant at the lower emission level. The commenter notes that the EPA is requiring a calibration gas
at a level equivalent to the emission limit, even if that means adding a fourth calibration gas level, and
that adding this calibration gas level will cause significant cost and significant modifications to Data
Acquisition and Handling Systems (DAHS). In addition, the commenter notes part 75 already has
existing requirements to ensure the monitor span value is set at a level to cover the range of the unit's
operating emissions.

Comment 25: Commenter 17873 believes the increased QA/QC requirements for SO2 CEMS as a
surrogate for HC1 emissions goes well beyond what the EPA has previously required in either 40 CFR
parts 60 or 75 monitoring requirements, and the EPA does not provide adequate justifications for
increasing these QA/QC requirements beyond what part 75 requires. The commenter believes the fourth
linearity calibration injection standard is overly burdensome to the industry.

Comment 26: Commenter 17775 believes no reason was provided for the requirements in the proposed
section 63.10010(e)(6)(i) and (ii) that allows use of an S02 CEMS meeting part 75, but imposes linearity
and 7-day calibration error test requirements not required under part 75. The commenter cites 67 FR
40394 and 40408-09 (June 12, 2002) in which the EPA specifically exempted CEMS with spans of 50
ppm or less from the 7-day calibration error requirement under part 75 because it was no longer
necessary. The commenter also cites 63 FR 28032 and 28061/3 (May 21, 1998) where the EPA
specifically exempted spans of 30 ppm or less from the linearity requirement in acknowledgment of the
fact that the tests were no longer significant at low emission levels. The commenter suggests if these
tests are no longer relevant or significant, there is no purpose in requiring them in this rule and that
requiring the test will complicate compliance for EGUs currently complying with part 75 without
providing any added accuracy to the measurement.

Comment 27: Commenters 17775 and 17820 believe the EPA provides no rationale for this added
requirement in proposed section 63.10010(e)(6)(iii) that requires a calibration gas at a level equivalent to
the emission limit, even if that would result in a fourth calibration level. The commenters note part 75
already includes provisions to ensure that the analyzer span value is set at a level that will result in use
of calibration gases that are consistent with the emissions range over which the unit operates, citing 40
CFR part 75, Appendix A section 2.1.1. The commenters believe there is nothing to be gained by
potentially adding a fourth calibration gas, and since existing SO2 CEMS and the accompanying DAHS
have not been certified using a fourth calibration gas, and are not currently designed to support a fourth
calibration gas, this new requirement would unnecessarily increase costs for SO2 CEMS. The
commenters believe the EPA must remove these requirements, or issue for comment a proposal that
provides some rationale for requiring these tests in this context.

Comment 28: Commenter 17821 strongly opposes the requirements in section 63.10010(e)(6)(iii) to
introduce a fourth concentration level of calibration gases during the initial and subsequent quarterly
linearity audits. The commenter states the EPA appears to be imply that more accurate measurements
would be obtained by the SO2 monitoring system if the fourth level of calibration gases was added;
however, the commenter believes no additional accuracy would be obtained by the introduction of an
additional gas injection level, and it would simply consume additional resources and slow down a test
that already takes 2-3 hours to complete. The commenter also believes it would also necessitate the
invalidation of hourly data during the injection of the linearity gases. The commenter notes that by

185


-------
adding the fourth gas injection level, sources would be forced to inject gases for approximately 40
minutes (10 minutes for each of the four gas concentrations); when the 5-7 minutes required to reach a
stable stack gas reading are added to that total, sources would not collect enough valid stack
measurement minutes within an hour to validate the hour. The commenter therefore believes this process
would result in approximately 2-3 hours of invalid data each and every quarter.

Commenter 17821 additionally states the alternative limit when using an SO2 emissions system for
compliance with an HC1 limit under these proposed rules is defined in terms of lb/MMBtu. SO2 and
diluent monitors (O2 or CO2) are audited for linearity in ppm concentration or percent concentration, not
as a value expressed in lb/MMBtu. The commenter believes to require a source to evaluate an SO2 or
diluent monitor for linearity at a fourth concentration level "nominally at the concentration level
equivalent to the applicable emission limit" would be extremely subjective. The commenter states that
concentrations of SO2 and diluent gases can change as the unit load changes due to the amount of excess
air being supplied to boilers at various loads. This variability in the air excess flow would result in a
change to the nominal equivalent values for the test.

Commenter 17821 continues to state that sources currently using S02 monitoring systems in compliance
with 40 CFR 75 are required to develop span ranges that capture the majority of the hourly averages
between 20% and 80% of the span range. According to the commenter, with this requirement in place,
most sources are utilizing span ranges that are set to capture the majority of nominal readings at
approximately 50% of that span range. 40 CFR 60 and 40 CFR 75 cylinder gas audits and linearity
audits already require a source to inject a gas in the range of 50% to 60% of the span range of the
monitor; therefore, an injection of audit gas in the "nominal" range of measurement is typically
performed. Additionally, states the commenter, all sources equipped with SO2 emission control systems
utilize dual range S02 monitoring systems (as required by both 40 CFR 60 and 40 CFR 75). The
commenter believes performing a linearity audit with a fourth injection level on the high range of the
S02 monitor at the "nominally at the concentration level equivalent to the applicable emission limit"
would be meaningless as the high range of the monitor is not intended to measure low level
concentrations but is designed to measure higher concentrations in the event of a malfunction or upset of
the SO2 emission control system. The commenter believes very low concentrations of SO2 will dictate
very low range measurement on these dual range analyzers, which will make passing a linearity test very
difficult. The commenter states that the standard is percent of the reference value, which may put the
error limits inside the accuracy standards for the reference gas. The commenter states that part 75
provides a waiver for linearity testing of ranges less than 50 ppm and an alternate standard for ranges
less than 200 ppm. The commenter recommends that these be allowed for the S02 surrogate
measurement as well, which will also serve to avoid maintaining separate databases for CSAPR and
MACT purposes.

Comment 29: Commenter 17881 believes the restrictions and caveats placed on the use of part 75 SO2
CEMS at section 63.10010(e)(6), the provisions of paragraphs (i) and (ii) would require that 7-day
calibration error tests and linearity tests be conducted on low-level emissions monitoring systems (i.e.,
systems with span values of less than 50 ppm or 30 ppm, as applicable) make little sense, as the EPA has
already evaluated the utility of conducting such tests under 40 CFR part 75 and concluded that these
tests were not appropriate for level-level emissions monitoring systems.

Commenter 17881 believes the provisions of section 63.10010(e)(iii) which would also require that at
least one calibration gas level used for the linearity tests have the same nominal concentration level
equivalent to the applicable emission limit (and that a fourth such gas be used if none of the required
low, mid or high gases meet this requirement) are nonsensical, as the vast majority of part 75 SO2

186


-------
CEMS installed on units with add-on SO2 control devices will be dual-range instruments. As such, states
the commenter, the high level range of these instruments will generally be reflective of S02 emissions
without add-on SO2 controls, which will surely be much higher than the applicable SO2 emission limit,
and thus, the S02 CEMS will be calibrated over an aggregate (i.e., low and high) measurement range
which encompasses the applicable SO2 emission limit, and this should be adequate to ensure the
accuracy of the S02 CEMS measurements at or near the applicable emission limit. The commenter
suggests a more reasonable caveat (in lieu of section 63.10010(e)(6)(iii)) would be a prohibition on the
use of a default high range value as allowed under 40 CFR part 75, Appendix A, section 2.1.1.4(f) for
those dual span units with SO2 emissions controls. According to the commenter, this would essentially
ensure that any EGU which elects to comply with a surrogate S02 limit (which inherently requires add-
on SO2 controls) has quality assured SO2 measurement ranges which encompass the applicable SO2
emission limit.

Commenter 17881 believes the concept of a calibration gas with a concentration nominally equivalent to
the applicable SO2 emission limit is unworkable, as the SO2 emission limits are not inherently expressed
on a concentration basis (i.e., are expressed as lb/MMBtu or lb/MWh), are assessed on a 30-day rolling
average basis, and would be influenced by boiler operating loads and the resulting diluent gas levels and
electrical outputs. The commenter provides an example for a subbituminous boiler and questions that
given the concentration equivalent of a given SO2 emission limit is influenced by boiler operating
conditions, how could a nominally equivalent concentration even be determined with any level of
certainty. The commenter also questions what is nominally equivalent in the context of the example
provided.

Comment 30: Commenter 17902 believes section 63.10010(e)(6)(i) thru (iii) will require additional
calibration error and linearity check tests that are not currently required under 40 CFR part 75 and are
not necessary and may not even be feasible due to instability of calibration gases at lower concentration
levels. The commenter recommends that the final rule should not require additional S02 CEMS
requirements beyond the QA/QC requirements and guidance in the existing federal regulations for 40
CFR part 75.

Comment 31: Commenter 17868 suggests the EPA allow all part 75 exceptions. The commenter notes
proposed section 63.10010(e) allows use of an SO2 meeting part 75, but disallows the linearity and 7-
day calibration error test exceptions and requires a calibration gas at a level equivalent to the emission
limit (even if it is a fourth level).

Comment 32: Several commenters (17775, 17800, 17811, 17868, 18014) note that proposed section
63.10021(a)(13) sets out the ongoing requirement for SO2 CEMS, which are similar to proposed section
63.10010(e), except this provision does not reference the part 75 option. One commenter suggests the
EPA reference the part 75 alternative in this provision as well, or consolidate the two provisions.

Comment 33: Commenters 17725 and 18498 note that section 63.10010(e)(6)(ii) states that one "must
perform the linearity check test required in appendix A to part 75 on the S02 CEMS whether or not it
has a span of 30 ppm or less"; however, this requirement ignores the EPA's previous acknowledgement
that a linearity check "begins to lose its significance" at span values less than or equal to 30 ppm as
discussed in the proposed 1998 revisions to 40 CFR part 75. One commenter provides an example and
proposes the requirement should be removed and replaced with the part 75 exemption.

Comment 34: Several commenters (17725, 18014, 18498) reference section 63.10010(e)(6)(iii), which
states "the initial and quarterly linearity checks required under Appendix B of Part 75 must include a

187


-------
calibration gas (at a fourth level, if necessary) nominally at a concentration level equivalent to the
applicable emission limit." The commenters see no reason to introduce a fourth calibration gas and the
term "nominally" is not clearly defined. The commenters state that part 75 has requirements in place to
ensure that the analyzer span is set to obtain accurate and representative data. Commenter 17725 notes
this requirement will significantly increase SO2 CEMS operating cost as the system will need to be
modified to include an additional regulator, the DAHS will need to be reprogrammed, and costs will be
incurred to purchase a fourth calibration gas (including monthly cylinder demurrage).

Comment 35: Commenter 17752 requests the EPA clarify what "if necessary" means in section
63.10010(e)(6)(iii) in regards to conducting linearity checks at a fourth level. The commenter believes if
an EGU qualifies for and elects to use a SO2 CEMS, yet has a state limit that is more restrictive, there
would be no benefit to having a fourth level at the proposed applicable emission limit. According to the
commenter, any emission limit will reside in the lower range of a dual range analyzer, which is typically
a narrow range to begin with. The commenter believes this requirement is "not necessary" and would
only add complications and costs to an already accurate and sound system.

Comment 36: Commenter 17821 supports the EPA's inclusion of the option to operate, maintain, and
quality assure an SO2 monitoring system under 40 CFR 75 if the source operates such a system for
compliance with Acid Rain.

Comment 37: Commenter 17886 suggests the EPA harmonize the S02 CEMS requirements with part
75 as most if not all EGUs should already have these systems in place meeting part 75 requirements.
The commenter believes failure to harmonize monitor requirements in past regulations has created
confusion and additional costs for both the EGU and the EPA.

Comment 38: Commenter 18014 states that in Table 5 for the SO2 CEMS (Item 5) in the "using"
column for Item a, the table should include the alternative to use Part 75 requirements for "installation",
"operate", and "maintain CEMS." (See section 63.10010(e).) The commenter also notes the table
references section 4.1.3 and 5.3 of Appendix A to the subpart, but SO2 is never mentioned in Appendix
A.

Comment 39: Commenter 17881 objects to subjecting part 75 monitoring systems to the data reduction
procedures in section 63.10010(e)(4), as these procedures are in part inconsistent with the part 75 data
reductions procedures at section 75.10(d). The commenter cites the requirements from section 63.8(g)(2)
and section 75.10(d)(2), noting that while the language appears similar, it could still result in different
data validation cases where maintenance or quality activities are conducted in a given hour and only two
data quadrants are used to validate the hour. For example, states the commenter, if an unit operated for
60 minutes in a given clock hour and collected valid 1-minute values at minutes 14 and 15 due to quality
assurance activities, such an hour would be valid under the provisions of section 63.10010(e)(4) but
invalid under the 40 CFR 75.10(d)(1) provisions. The commenter believes forcing part 75 subject
sources to maintain two separate sets of data based upon two different validation regimes is overly
burdensome and unwarranted, and suggests part 75 S02 CEMS should not be subject to the provisions
of section 63.10010(e)(4).

Comment 40: Commenter 18014 suggests the EPA should add a subsection to section 60.10010(e),
which clarifies that bias adjusted data and part 75 missing data shall not be used in calculating the 30
boiler operating day average SO2 emission rate. According to the commenter, although this is discussed
in Appendix A to subpart UUUUU for Hg CEMS (Reference Appendix A sections 1.4 and 4.1.2.4), this
data exclusion is not clearly stated for SO2 CEMS.

188


-------
Response to Comments 22-40: After reviewing the comments and assessing the need for a "nominal"
gas for the linearity test, the EPA has removed this requirement from the final rule while retaining a
requirement for a linearity check even for low SO2 concentrations. Sources can already report linearity
tests for these units within the context of the existing ECMPS reporting without triggering any critical
errors regardless of the test results. This test can be accommodated within the current framework
without causing issues for part 75 reporting. The 7-day calibration error test is removed as unnecessary.
As noted elsewhere in this response to comments document, the final rule confirms that the bias
adjustment and substitute data provisions under part 75 do not apply when using an S02 CEMS to
demonstrate compliance with the SO2 emission limit in this rule.

189


-------
5A09 - Testing/Monitoring: Application of HC1 CEMS

Commenters: 16513, 17383, 17402, 17621, 17622, 17627, 17638, 17681, 17696, 17704, 17705, 17715,
17716, 17718, 17724, 17725, 17728, 17729, 17756, 17769, 17775, 17790, 17795, 17800, 17813, 17820,
17821, 17851, 17868, 17881, 17886, 18014, 18037, 18443, 18539, 19114, 18023

1. HC1 CEMS is not proven technology.

Comment 1: Numerous commenters (17383, 17402, 17681, 17696, 17704, 17705, 17715, 17718,
17724, 17728, 17729, 17627, 17638, 17769, 17775, 17790, 17795, 17813, 17820, 17868, 18037, 18443,
18539, 19114, 18023) note concerns with HC1 CEMS technology.

Comment 2: Commenter 17402 recommends that the EPA remove the HC1 CEMS monitoring
requirement from the proposed rule until HC1 CEMS are proven technologies. The commenter states
that EGU sources have limited experience with HC1 CEMS, and limited information on the accuracy and
long-term performance of such technologies as applied in the field. The EPA proposes an HC1 standard
equivalent to approximately 2 ppm, which the commenter believes is an extremely low performance
standard for a new monitor to meet.

Comment 3: Commenters 17638 and 17681 state that there are no FTIRHC1 CEMS currently in use in
the U.S. on a coal-fired EGU.

Comment 4: Commenter 17813 does not believe HC1 CEMS are in production and questions if there
are any HC1 CEMS that work.

Comment 5: Commenter 17696 states that while the EPA suggests that FTIR CEMS may be
appropriate to monitor HC1 emissions pending promulgation of a performance standard specific to HC1
CEMS, 76 FR 25031, FTIR does not have a track record of consistently and reliably measuring HC1
levels expected in the stack gas of EGUs.

Comment 6: Commenter 17704 believes the technology for HC1 CEMS is not fully developed or
proven for EGUs. The commenter understands that stack testing for HC1 every month is offered as an
alternative, but scheduling testing that often is difficult and not practical; therefore, that really only
leaves the choice of HC1 CEMS. The commenter believes that HC1 CEMS have been used to measure
higher concentrations for other industries; however they are not proven at the low levels proposed in the
rule.

Comment 7: Commenter 17705 believes the use of HC1 CEMS has been attempted primarily on dry
stacks, and that HC1 CEMS may not be available for use on wet stacks, noting concern that many EGUs
plan to use wet FGD technology to comply with the proposed acid gas standards. In addition, states the
commenter, information provided by EPRI indicates that the proposed HC1 standard may be lower than
the quantitation limit of the two types of instruments currently available for HC1 measurement. If the
EPA retains a numeric HC1 standard in the final rule, the commenter encourages the EPA to take a
leadership role in assuring that the monitoring methodology that is required is actually available for use
across a broad range of plant configurations and can reliably demonstrate compliance with the standard.

Comment 8: Several commenters (17718, 17627, 17715, 18037, 18539) state HC1 CEMS currently are
not commercially available or adequate for in-stack measurements and likely will not be available by the
compliance date of the rule. The commenters believe sources will be forced to either take a fuel limit or

190


-------
an operating parameter limit. The commenters state the fuel analysis limit is impractical as it relates to a
coal-fired facility because of the variability that is inherent in coal, and that it will be impossible to
control fuel deliveries in such a manner as to negate the possibility of burning coal with chlorine content
above that which was used during compliance testing.

Comment 9: Commenters 17715 and 19114 state HC1 is not routinely monitored by EGUs, and there is
little stack test data beyond that collected by the EPA during the ICR process. The commenter states that
no HC1 continuous monitors were used to collect any of the data used by the EPA to establish the HC1
standard, and there is no information about HC1 emissions at conditions other than normal full load
operations, but nevertheless, the EPA proposes to rely on continuous HC1 monitors as its preferred
monitoring method for compliance. The commenter believes it is imprudent for the EPA to set forth a
monitoring standard for which there has been very limited experience in the relevant industry and for
which the technology has not been commercially developed. The commenter notes that the EPA states
that FTIR has been shown to be adequate for in-stack measurements. However, the commenter states
FTIR has been shown to be unreliable in stack applications, especially at emission rates as low as the
EPA has proposed. The commenter recommends the EPA should not dictate FTIR as the technology to
be utilized.

Comment 10: Several commenters (17383, 17724, 17820) are concerned that HC1 monitors are not a
proven option in the electric utility industry. According to the commenters, while these monitors exist
and have operated on other sources, the electric utility sector presents distinct challenges. Commenter
17724 questions the need for SO2 monitoring in addition to parametric monitoring associated with
scrubber operation.

Comment 11: Commenter 17728 believes HC1 CEMS are not at this point a viable option, as the
technology remains unproven. The commenter expresses concerns about the ability of HC1 CEMS to
accurately measure compliance with the proposed standard.

Comment 12: Several commenters (17728, 17775, 17820) believe the EPA must consider the
limitations of compliance measurements when setting enforceable standards.

Comment 13: Commenters 17718 and 17729 state at the EPA emission rate of 0.002 lb/mmbtu, the HC1
in the flue gas will be less than 2 ppm. The commenters believe that currently, HC1 CEMS are not
capable of measuring accurately at concentrations below 2 ppm.

Comment 14: Several commenters (17775, 17868, 17820) are concerned about the ability of HC1
CEMS to accurately measure compliance with the proposed standard because the limit is at or near the
detection limit for current HC1 CEMS technology.

Comment 15: Commenter 17790 states that while there are limited HC1 CEMS installations, they are
not a proven technology like SO2 or NOx CEMS. The commenter also suggests there are significant
technology obstacles in applying HC1 CEMS to a wide variety of sources with different temperatures,
moisture and gas conditions. The commenter notes its own experience with significant problems with
Hg CEMS, the heated umbilical (a critical part of the CEMS) is unproven at extended lengths (over 200
feet).

Comment 16: Commenter 17769 believes there are valid technical concerns regarding the feasibility
and commercial acceptance of the use of HC1 CEMS, particularly that the reactivity of HC1, makes
obtaining reliable measurements a difficult task. The commenter identifies the three basic HC1 CEMS

191


-------
configurations and discusses technical issues with each. The commenter describes sample conditioning
problems associated with extractive systems, difficulties with representative measurements and
operation and maintenance (O&M) problems for in-situ instruments, and NH3 interactions with HC1
creating problems for dilution sampling systems. The commenter also discusses the MCS 100 E Multi
Component Analyzers as the most widely employed and presumably most advanced HC1 CEMS and
notes issues with detection limits associated with the use of the unit. The commenter believes there are
substantial technical questions regarding the use of HC1 CEMS, and the EPA should not require them as
part of the EGU NESHAP.

Comment 17: Commenter 17795 believes that HC1 CEMS are not an option at the proposed levels with
a certification performance specification that has a known negative bias. For existing units, states the
commenter, an HC1 standard of 0.002 lb/MMBtu equates to 1.2 ppm (assuming a heat rate of 10,000
Btu/kW). The commenter believes while this value is above the detection limit it will be extremely
challenging to demonstrate compliance through a continuous HC1 emissions monitor. For example,
states the commenter, the lowest achievable emission rate (LAER) for new combined cycle combustion
turbines is approximately 2.0 ppm of NOx- Unlike HC1, NOx is not water soluble or temperature
dependant prior to analysis. The commenter notes their industry has more than 30 years of experience
monitoring NOx and limits of 2.0 ppm are challenging to demonstrate on a continuous basis. According
to the commenter, measuring a highly water soluble compound that is expected to be less than 1.2 ppm
where water is a large part of the sample matrix will be problematic and may simply result in unreliable
data.

Comment 18: Commenter 18443 believes the cost and accuracy of HC1 CEMS do not justify the
difference in emission reduction measurements produced by a performance test and continuous
compliance metrics. The commenter suggests HC1 CEMS were developed for sources with much greater
HC1 emissions than EGUs and as such do not provide precision and accuracy at the range they are
expected to operate. Additionally, states the commenter, the HC1 standard does not take into account
chlorine variability in coal. The commenter recommends instead of effectively mandating HC1 CEMS,
EPA should allow sources to comply with HC1 limits through an annual performance test, in conjunction
with documented process metrics.

Comment 19: Commenter 19114 notes that HC1 is not routinely monitored by electric generating units,
and there is little stack test data beyond that collected by the EPA during the ICR process. No HC1
continuous monitors were used to collect any of the data used by the EPA to establish the HC1 standard,
and there is no information about HC1 emissions at conditions other than the limited data available for
normal full load operations. The commenter believes it is imprudent for the EPA to set forth a
monitoring standard for which there has been very limited experience in the relevant industry and for
which the technology has not been commercially developed. The EPA states that FTIR has been shown
to be adequate for in-stack measurements. However, FTIR has been shown to be unreliable in stack
applications, especially at emission rates as low as the EPA has proposed. Given these (and other)
uncertainties regarding FTIR performance, the commenter believes the EPA should not dictate FTIR as
the technology to be utilized. The commenter provides several examples of concerns expressed by
agencies regarding the use of HC1 CEMS, including excerpts from state agencies in their Response to
Comments document that supported the issuance of final air permits.

Comment 20: Commenter 18023 believes there is only one HC1 CEMS in operation in the U.S. on a
coal-fired power plant stack and it is a tunable diode laser (TDL) based device. The commenter states
TDL is not the EPA's preferred FTIR technology, so there is no performance specification available for
it. The commenter states that this existing TDL device also uses the open path measurement approach

192


-------
and, as such, does not lend itself to daily QA/QC procedures typical of the power plant CEMS
equipment that meets Part 75 requirements. According to the commenter, the current technology (FTIR)
used for stack testing is not very rugged; sample transport issues may require HC1 CEMS analyzers to be
stack mounted, which will provide a maintenance and availability challenge. According to the
commenter, most analyzers require stable temperature and humidity that would be difficult to manage
on a stack exposed to ambient or above ambient temperatures.

Comment 21: Commenter 18023 suggests HC1 CEMS must work at extremely low concentrations to
meet the proposed MACT standard. The commenter states that NIST does not have any HC1 standards,
and the lowest concentration of EPA Protocol HC1 gas advertised by a gas vendor is 25 ppm. The
commenter states that that value is based on gravimetric (weight) traceability, and converted to ppm, the
limit in the proposed rule is approximately 1 ppm. According to the commenter, this limit may be below
the quantitation limit (QL) of the available instruments and thus would not be measureable.

Response to Comments 1-21: The EPA disagrees with commenters' contention that continuous HC1
monitoring is premature or not available for the measurement at the limits set in the proposed standard.
We understand from vendors of HC1 CEMS that they have been used on source categories such as
municipal waste combustors, cement plants, and biomass and other power generation units. We have
reviewed HC1 CEMS vendor technology claims and found sufficient capability to support this rule
requirement. We are presently engaged with representative stakeholders to develop a generic
performance specification for HC1 CEMS. The HC1 Performance Specification is scheduled for
completion in time to be responsive to this rule promulgation. To use the HC1 CEMS option at the start
of the program, the EPA has included a comparable performance specification PS 15, using a Fourier
Transform Infrared (FTIR) analyzer, which could be employed in the event that the issuance of PS for
HC1 CEMS is delayed. Should an EGU owner or operator be concerned about using HC1 CEMS as a
compliance demonstration method, other options exist for acid gas HAP monitoring including: 1) using
HC1 CEMS for compliance, 2) seeking approval for an alternative HC1 monitoring procedure through
section 63.7 f., 3) monitoring SO2 continuously as a surrogate for HC1 at facilities equipped with wet
scrubber control technology for S02. and 4) frequent reference method testing. Including these options in
the rule provides flexibility to adopt CEMS monitoring options as the technology continues to mature
and EPA performance specifications become available.

Comment 22: Commenter 17622 states they recognize the reluctance of the utility industry to proceed
with plans to measure HC1 because 1) They know it can be difficult to measure in low concentrations; 2)
The technologies used for it such as FTIR, TDL or Perma Pure driers with GFC analyzers are unfamiliar
to them; 3) The EPA has not published performance specifications for HC1 measurement leading to
some uncertainty. The commenter believes that if electric generating facilities can identify a reliable,
low-maintenance, affordable option for low level HC1 measurement (0-10 ppm), they will adopt it more
readily. The EPA should help try to prove this point out over the coming months.

Response to Comment 22: The EPA acknowledges that certain applications of HC1 CEMS will require
further demonstrations and advances for this technology and is currently working on HC1 PS for
technologies other than FTIR.

2. Concerns over lack of performance specification.

Comment 23: Multiple commenters (17402, 17638, 17681, 17696, 17716, 17728, 17729, 17769, 17800,
17820, 17821, 17851, 17868, 17881, 17868, 17881, 17886, 18014, 18023) express concern that the
agency has not made available performance specifications for HC1 CEMS.

193


-------
Comment 24: Commenter 17402 states the absence of such requirements makes it difficult for regulated
units to comment on how they might comply with the proposed QA/QC specifications in the context of
the Utility MACT rule.

Comment 25: Commenter 17696 believes it is premature and inappropriate for the EGU NESHAP rule
to specify the use of HC1 CEMS given that the EPA has not yet promulgated a performance standard
specific to HC1 CEMS. Without the existence of an accepted performance specification for HC1 CEMS
in advance of the compliance dates, the commenter believes EGUs cannot reasonably be expected to
purchase and install HC1 CEMS and rely on them for compliance determinations.

Comment 26: Several commenters (17716, 17820, 18014) state the EPA has developed no performance
specification for non-FTIR based HC1 CEMS. Table 5 lists PS 6, but the commenters believe PS 6 does
not apply since it is for systems that measure pollutant emissions in units of mass per unit of time. The
commenters state the lack of a performance specification for HC1 CEMS (coupled with limited utility
HC1 CEMS operating experience, particularly for compliance near the detection limits of the systems)
makes it difficult to provide meaningful comments.

Comment 27: Commenter 17729 recommends the EPA should not require compliance monitors for
which an EPA performance specification does not exist.

Comment 28: Several commenters (17775, 17795, 17800, 17868) note that the EPA proposes to require
certification of HC1 CEMS according to PS 15 or PS 6. The commenters state that as the EPA
acknowledges in the preamble, PS 15 applies only to FTIR CEMS. PS 6 applies to continuous emission
rate monitoring systems ("CERM"), which measure mass emissions rate per unit of time, not
conventional CEMS. The commenters note FTIR CEMS is not a viable option and sources need a well
documented HC1 performance specification well in advance of the compliance date in order to evaluate
and procure appropriate instrumentation. The commenters state that in order to provide an HC1 CEMS
option, the EPA says "we expect to publish (a performance specification) prior to the compliance date of
this proposed rule and to make it available to source owners and operators" (76 FR 25031). The
commenters believe in the absence of an existing specification, the EPA should recognize in the rule that
PS 15 does not apply to HC1 CEMS.

Comment 29: Several commenters (17775, 17795, 17800, 17820, 17868) support the EPA's decision to
convene a workgroup of interested stakeholders to aid in development of an appropriate performance
specification. The commenters suggest the EPA allow EGUs to petition the EPA for use of an
alternative specification if none has been promulgated by the time EGUs need to make decisions about
their compliance options.

Comment 30: Commenter 17868 notes they supports the option for use of HC1 CEMS and urges the
EPA to complete work on a reasonable performance specification.

Comment 31: Commenter 17886 recommends that the EPA make HC1 CEMS monitoring requirements
contingent upon issuance of an HC1 CEMS performance specification, as an HC1 CEMS Performance
specification is not currently available and the EPA has set the proposed HC1 limits near the detection
level of current technology. The commenter also believes, since the proposed limits are lower than the
quantification limits of current technology, HC1 CEMS should only be used for purposes of CAM.

Comment 32: Commenter 17881 has generally heard that the FTIR technology associated with PS 16 is
not a viable option at this point in time due to concerns about detection limits in EGU exhaust gas

194


-------
matrices, potential measurement issues in wet stack environments, lack of low-level calibration
standards, etc. The commenter suggests that until such time as the EPA has promulgated performance
specifications for HC1 and HF, the EPA should allow affected EGUs to petition for the use of an
alternate performance specification. The commenter notes it is possible that new EGUs may face a
compliance date as early as 1/1/2012, and believes it is highly unlikely that an HC1 PS can be developed
by that time. The commenter also notes it is not possible to comment on the QA requirements for HC1
CEMS when there is no performance specification available.

Comment 33: Commenter 17769 notes that there are no performance specifications or quality-assurance
provisions for HC1 CEMS and the commenter is not aware of any FTIR HC1 CEMS currently in use in
the U.S. on a coal-fired EGU. The commenter notes that currently no federal regulations require the use
of HC1 CEMS without express exemptions, alternatives and caveats. The commenter provides examples
including the Portland Cement NESHAP, CISWINSPS and the proposed NESHAP for Polyvinyl
Chloride and Copolymer Production. The commenter cites several rulemakings in which the EPA
expressed various reasons for its hesitation to require the use of HC1 CEMS, including lack of data,
significant costs, and lack of performance specifications. The commenter believes the EPA's rationale
for not adopting performance specifications (specifically, PS-13) is that the EPA could not demonstrate
that an HCI CEMS would meet the specifications, citing 64 FR 52828, 52930. The commenter believes
there is no certainty over the suitability and reliability of HC1 CEMS and that the EPA must provide
public notice and an opportunity for comment on any specifications prior to EPA requiring them as part
of any rule.

Comment 34: Commenter 17821 encourages the EPA to allow the use of alternate HC1 CEMS
performance specifications so the choice of HC1 CEMS is not limited to FTIR monitoring systems. The
commenter believes that because the FTIR is not a practical monitoring option, using an HC1 CEMS is
not a realistic option for companies to consider without another option. According to the commenter,
therefore many sources would have to revert to either using S02 as a surrogate, or to conducting stack
testing at an unreasonable frequency. The commenter believes FTIR CEMS are difficult to calibrate and
maintain. They typically require a level of expertise to set up, operate, and maintain that is far above the
typical CEMS technician found at a power generation facility. The commenter notes that some states,
including Indiana and Pennsylvania, have approved the use of alternate performance specifications for
HC1 CEMS on hazardous waste incinerators allowing the use of HC1 CEMS other than those based on
FTIR methods.

Comment 35: Commenter 17851 believes the EPA should not apply PS 15 to HC1 CEMS, but should
promulgate a PS specifically designed for these instruments. The commenter notes most commercial
HC1 CEMS use some form of infrared light attenuation to measure HC1 concentrations and that
requiring HCI CEMS to use PS 15 is simply not appropriate. The commenter believes the EPA should
promulgate a performance specification specifically for HCI CEMS much like they have performance
specifications for other CEMS (e.g., PS 11 for PM CEMS, and PS 12A for Hg CEMS, etc.). The
commenter also believes that it is not appropriate to require compliance with an HCI CEMS unless there
is a promulgated performance specification for HCI CEMS. The commenter suggests that these CEMS
should not be required until a performance specification for these types of units is promulgated.
However, if the agency decides to require these CEMS, the commenter believes there is a better interim
solution than PS 15. The EPA has already approved two preliminary other test methods for HCI CEMS,
OTM 22 and 23. The commenter believes that it makes more sense to temporarily use a preliminary test
method already approved for HCI CEMs than to use an already promulgated performance specification
that may not apply. The commenter suggests that the EPA modify the final rule to allow the use of OTM
22 and 23 instead of PS 15.

195


-------
Comment 36: Commenter 18023 believes it is inappropriate to require HC1 CEMS without appropriate
industry practice demonstrating their availability and without a relevant Performance Specification.

Commenter 17775 states that the EPA must provide a reasonable performance specification for HC1 and
HF CEMS in time for EGUs to make decisions regarding compliance options.

Response to Comments 23-36: See Response to Comments 1-21 under 5A09 of this document.

3. Proposed alternatives.

Comment 37: Commenter 17704 believes as an alternative, a stack test emission factor based on an
annual stack test would be more appropriate for their Powder River Basin (PRB) subbituminous coal
units. According to the commenter, the amount of chlorine in the PRB coal the commenter utilizes does
not vary much over a year, and a once per year stack test emission factor would be a sufficient means of
calculating HC1 emissions. The commenter suggests adding an option that would have an alternative for
using a stack test emission factor instead of HC1 CEMS, as long as, the fuel utilized by the unit does not
change during the year. The commenter states that if a new fuel is introduced a new stack test could be
required.

Response to Comment 37: The rule provides an alternative to an HC1 CEMS based on periodic stack
testing. See section 63.1006(j) and (k). The required testing frequency is more frequent than the
suggestion made by the commenter.

Comment 38: Commenter 17728 recommends that if no performance specification is forthcoming by
the time decisions about compliance options need to be made, the EPA should allow EGUs to petition
for use of an alternative specification.

Response to Comment 38: Sources may petition for an alternative specification consistent with the
provisions of section 63.7.

Comment 39: Commenter 17724 questions the need for S02 monitoring in addition to parametric
monitoring associated with scrubber operation. The commenter suggests that like PM, the EPA should
allow a source to choose either S02 monitoring or scrubber parametric monitoring in conjunction with
fuel analysis as a continuous compliance option, and that the EPA should not categorically create
secondary compliance monitoring.

Response to Comment 39: If an SO2 CEMS is used consistent with the alternative SO2 limit included
in the rule, no parameter monitoring requirement applies.

Comment 40: Commenter 17715 supports SO2 as a surrogate for HC1 at scrubbed units.

Response to Comment 40: The EPA acknowledges the commenter's support.

Comment 41: Commenter 17402 suggests in the alternative that facilities be permitted to utilize
monthly fuel sampling coupled with periodic stack testing to meet monitoring compliance obligations.

Response to Comment 41: The final rule eliminates the fuel sampling option. A source may use an
SO2 CEMS where an FGD is installed, may use HC1 CEMS, or may conduct periodic testing to
demonstrate compliance.

196


-------
Comment 42: Commenter 17696 believes until the EPA develops an accepted performance
specification for HC1 CEMS, that HC1 CEMS should be used for compliance purposes with the EGU
NESHAP rule only upon the EPA approval of an alternative monitoring method in accordance with 40
CFR 63.8(f).

Response to Comment 42: The EPA has set forth PS 15, which uses a Fourier Transform Infrared
(FTIR) analyzer as an acceptable alternative for HC1 CEMS performance specifications. Sources may
seek alternative specifications through section 63.7. See also Response to Comments 1-21 under 5A09.

Comment 43: Commenter 17775 suggests that in the absence of an existing specification, the EPA
should recognize in the rule that PS 15 does not apply to HC1 CEMS and allow EGUs to petition the
EPA for use of an alternative specification if none has been promulgated by the time EGUs need to
make decisions about their compliance options.

Response to Comment 43: See response to Comment 42, directly above.

Comment 44: Commenter 17621 believes there are three likely candidate technologies for continuous
measurement of gas-phase HC1: FTIR, tunable diode laser (TDL), and gas filter correlation (GFC);
however, there is little or no experience with any of these technologies on EGUs, although all three have
been used in Europe on municipal waste incinerators. The commenter states that the EPA has approved
a reference method using FTIR for HC1 in cement plant emissions. The commenter states that GFC is
widely used on waste incinerators in Europe for HC1 monitoring, but U.S. experience with this
technology on EGUs is limited to CO2 monitoring. According to the commenter, all of these
technologies operate in the near infrared range and are to some extent subject to interference from water
vapor, but both FTIR and TDL systems are able to resolve this interference.

The commenter notes with increasing measurement path there is a tradeoff between increased sensitivity
and loss of signal strength. According to the commenter, particulate and entrained droplets in the flue
gas can degrade the signal strengths in an in situ application in wet stacks, and demonstration of in situ
techniques in a wet stack environment needs to be conducted. An alternative approach is to extract a gas
sample and measure HC1. The commenter states that sample transport in a hot, wet flue gas is
problematic and would require multipass measurement cells to achieve sufficient path length for the
required sensitivity. Currently, states the commenter, the only installation on a U.S. EGU is an in situ
TDL on a dry stack, and in that application, there was sufficient intensity to measure HC1 and to identify
process variations. The commenter states that there is no experience with HC1 monitors on a wet stack;
the preferred installation by the suppliers is to make an in situ measurement, or at least place the
instrument close coupled to the stack, to avoid problems with condensation of HC1 during transport.

The commenter notes that the key tasks that need to be completed before an HC1 monitor can be
deployed and used for compliance measurements include: (1) Determine detection and quantitation
limits; (2) Quantify interferences of likely species in flue gas; (3) Validate CEMS in a wet stack; (4)
Develop alternative extractive sampling techniques; (5) Develop low-level calibration standards; and (6)
Develop and validate an EPA performance specification.

Comment 45: Commenter 17725 suggests HC1 CEMS should not be limited to FTIR monitoring
methodology as HC1 CEMS based on FTIR technology tend to be very expensive to maintain and are
labor intensive. The commenter suggests newer technologies such as Tunable Diode Laser Spectroscopy
(TDLS) and Ion Mobility Spectroscopy (IMS) are showing great promise as a suitable replacement for
selective gas components such as HC1 and HF.

197


-------
Response to Comments 44-45: The EPA acknowledges that certain applications of HC1 CEMS will
require further demonstrations and advances for this technology. The agency is working to finalize a PS
for HC1 CEMS (not limited to just an FTIR approach) and notes that the use of an HC1 CEMS is just one
option for demonstrating compliance under the final rule, not a requirement. The PS for HC1 CEMS will
include consideration of detection and quantitation limits, interferences, performance of CEMS under
site specific stack conditions, evaluating extractive as well as in-situ measurement techniques, and the
requirements for low-level calibration standards.

4.	Support of HC1 CEMS.

Comment 46: Commenter 17622 states the proposed rule suggests that using a compliance approach for
DSI of setting injection rate operational limits based on performance testing. According to the
commenter, because this approach could result in operators setting injection limits based on performance
testing with a higher reactivity sorbent and later substituting a lesser quality sorbent, compliance with
the HAP limit could be jeopardized. To avoid this potential issue the commenter recommends the use of
CEMS technology to facilitate ongoing HC1 emissions compliance. The commenter also recommends at
a minimum, if injection rate limits are utilized, reagent reactivity should also be specified.

Comment 47: Commenter 17756 supports the EPA's selection of HC1 as a surrogate for the other acid
gas HAP. The commenter also agrees with the EPA's proposal to allow EGUs the option of meeting an
alternative S02 limit, if a unit uses a CEMS device to demonstrate compliance with S02 limits.
According to the commenter, as drafted, proposed section 63.9991(a)(l)(i) limits the units that can
comply with an alternative S02 limit to those that have "wet or dry FGD technology installed on the
unit."

Response to Comments 46-47: The EPA notes the commenter's support for use of an HC1 CEMS. As
for the reagent reactivity concern, the general requirements for testing require that the tests be conducted
under normal conditions, which would include using the same quality sorbent during testing as is used
during operations. This type of deliberate violation of the regulations is considered unlikely as a general
concern, and will be best handled through effective compliance oversight and no change to the rule is
necessary. The EPA also acknowledges the support for the S02 alternate equivalent standard option
where that applies.

5.	Additional concerns.

Comment 48: Commenter 16513 notes that PSEG Bridgeport Harbor 3 is required to comply with the
S02 emissions rate or fuel sulfur content limits of Regulations of Connecticut State Agencies 22a-174-
19a, which PSEG accomplishes by use of low sulfur Indonesian coal. As a result, states the commenter,
PSEG Bridgeport Harbor 3 currently meets the Utility NESHAP's S02 limit of 0.20 lb/MMBtu for coal-
fired EGUs. The commenter states that under the Utility NESHAP, a unit with acid gas controls is not
required to install and operate an HC1 CEMS. The commenter suggests the EPA clarify whether or not
the use of low sulfur fuel would qualify as an acid gas control. The commenter believes if so, PSEG
Bridgeport Harbor 3 may forgo the installation of HC1 CEMS.

Response to Comment 48: The use of the S02 alternate equivalent standard option applies only where
an FGD is in use, because that control device ensures adequate acid gas control, and the monitoring of
S02 ensures proper operation of the control device. In the situation described, without an FGD installed,
the unit would not qualify for the S02 alternate equivalent standard and must meet the HC1 limit. The
source can demonstrate compliance using an HC1 CEMS or periodic HC1 testing.

198


-------
Comment 49: Commenter 17718 believes that within the proposed regulatory language of 40 CFR
63.10006, there does not appear to be an option for reduced HC1 performance testing requirements on
coal-fired units with non-HCl controlled bypass stacks. The commenter identifies a facility that is
currently configured to send its emissions to a common wet FGD shared with Unit 1 and 3 at the same
facility. The common emissions are then emitted through a common stack. The commenter states that all
three units are affected coal-fired units designed to burn greater than 8,300 BTU/lb coal, but Unit 2 is
also configured and permitted to utilize a bypass stack. According to the commenter, within the
proposed language of 40 CFR 63.10010(a)(4), it appears the facility's bypass stack would be required to
install similar monitoring systems as the main common stack, but without FGD technology on the
bypass stack, it appears that the current 40 CFR part 75 S02 CEMS located on the bypass stack could
not be used for compliance determinations as a surrogate for HC1. Furthermore, states the commenter,
even if the company desired to install an HC1 monitor on the dry stack to monitor emissions, it would
still be required to conduct performance testing every month because there apparently is not an option to
allow HC1 monitoring under 40 CFR 63.10006(i)-(k) to cover a non-HCl controlled unit/stack.

Response to Comment 49: The EPA has modified the requirements for monitoring a bypass stack.
Under the final rule, the installation of a monitor on a bypass stack is not required.

Comment 50: Commenter 17881 suggests section 63.10011 (b)(1), relating to establishment of a
maximum chlorine fuel input, should only apply to units which are not complying with the SO2
surrogate or are not relying on an HC1 CEMS.

Response to Comment 50: Under the final rule, no fuel input operating limits apply. The source may be
required to conduct a new performance test where there is a significant change in fuel use that could
result in emission increases.

Comment 51: Commenters 17724 and 17876 state that the CEMS the facility installed in preparation to
CAMR have significant reliability and operational issues (Hg, PM, HC1). Commenters 17724 and 17876
state that the EPA has left the long-term operational problems such as calibration gases to industry and
there are not accurate and reliable monitoring methodologies for demonstrating. Commenters 17724 and
17876 state the EPA purports to provide compliance flexibility while in reality there is very little
flexibility in light of the problematic and unproven nature of these monitoring technologies.

Commenter 17736 states the EPA cannot rely on unproven HC1 CEMS, that HC1 CEMS are not
commercially available to measure HC1 emissions from coal-fired EGUs, and no HC1 CEMS were used
to collect the data the EPA used to establish the HC1 standard.

Response to Comment 51: The agency disagrees with the commenters. As mentioned elsewhere, the
agency finds that the operation and maintenance issues for the CEMS mentioned are no different than
for other CEMS now in wide use and acceptance by the industry. The agency is aware that the
calibration gas issue is to be rectified well in advance of the rule's compliance date. The agency notes
that the rule is quite flexible with respect to compliance demonstration, containing numerous choices for
compliance, including the use of emissions testing alternatives for those EGU owners or operators who
remain concerned over use of CEMS or PM CPMS. The agency notes that FTIR CEMS exist now and
can be used to measure HC1 emissions continuously, that the HC1 emissions limit was developed from
emissions testing and has been adjusted to be appropriate for measurement with HC1 CEMS, and that
emissions testing options to demonstrate compliance exist for those EGU owners or operators who
choose not to use CEMS.

199


-------
5A10 - Testing/Monitoring: CEMS, General

Commenters: 15678, 16849, 17191, 17197, 17265, 17283, 17316, 17402, 17620, 17623, 17627, 17638,
17655, 17677, 17681, 17716, 17718, 17722, 17725, 17730, 17731, 17740, 17757, 17758, 17767, 17770,
17772, 17774, 17775, 17776, 17781, 17796, 17800, 17805, 17816, 17820, 17821, 17856, 17871, 17873,
17877, 17881, 17885, 17902, 17913, 17928, 18014, 18015, 18031, 18037, 18428, 18443, 18449, 18539,
19032, 19033, 19041, 19114, 19120, 19121, 19122, 19536, 19537, 19538, 18023

1.	Support for the PM CEMS, HC1 CEMS and Hg CEMS

Comment 1: Several commenters (15678, 17722, 19032) support the EPA requirements of installing
PM CEMS, HC1 CEMS and Hg CEMS to demonstrate continuous compliance with the emission
standards.

Comment 2: Commenter 17283 supports the EPA that monitoring is an integral part of emission
controls and that enhanced monitoring should be encouraged.

Comment 3: Commenters 17402 and 17620 support electronic reporting similar to the 40 CFR Part 75
ECMPS process.

Comment 4: Commenter 17740 supports the EPA that the Hg monitoring requirements established by
the CAMR are sufficient and appropriate requirements for the EGU MACT.

Response to Comments 1-4: The EPA appreciates the commenters' support for various provisions
involving CEMS. The final rule builds on the proposed provisions and clarifies what CEMS are allowed
to demonstrate compliance, whether Hg, HC1, HF, or SO2, as well as how to report that CEMS data
using ECMPS. In addition, upon request from a source owner or operator, the agency will consider
allowing use of multiple metals CEMS for non-Hg metals. Until a method and performance
specification for multiple metals CEMS is promulgated, source owners or operators wanting to request
their use should consider having their applications consistent with the draft multiple metals CEMS
method and performance specifications located at the following internet address: <
http://epa.gov/ttn/emc/prelim/otml9.pdf>.

Given the low non-Hg metals and PM emissions limits and possible difficulties in using PS 11 to certify
PM CEMS at those low levels, the rule no longer requires the use of PM CEMS. Rather, PM CPMS, in
which a PM detecting instrument is used as a parameter monitor is contained in the rule. Continuous
parametric data from the PM CPMS signal will be collected and reported to the agency's central data
exchange. The final rule also does provide for the use of a PM CEMS to determine compliance with the
filterable PM emission limit if the source elects to use this approach (see the final preamble for further
discussion). In that case, the PM CEMS is used as the direct method of compliance and no additional
testing is required other than tests that are required as part of the QA requirements in PS 11.

2.	Opposition based on testing requirements.

Comment 5: Commenter 16849 states that the proposed rule does not include provisions to use the 40
CFR Part 75 "conditionally valid data procedures." For example, states the commenter, if a CEMS fails
a linearity check, the CEMS remains out-of-control until the successful completion of a subsequent
linearity check, and this would require the operator to invalidate the 40 CFR part 75 conditionally valid
data (for SO2, CO2, O2, or flow monitors) for EGU MACT recordkeeping and reporting purposes.

200


-------
According to the commenter, a clearer approach would allow quality-assured data from a CEMS
certified and operated in accordance to 40 CFR part 75 to be used for compliance with the exception of
bias-adjusted and missing data.

Response to Comment 5: For the CEMS data that will be reported through ECMPS, the EPA has added
provisions to harmonize these reporting elements so that the data are reported in a consistent manner,
including conditionally valid data procedures. The exceptions are that no missing data or bias provisions
in part 75 are applied for purposes of complying with these standards.

3. Opposition based on limitations to the technologies.

Comment 6: Commenter 16849 states that there are known limitations to the technologies available to
monitor the surrogate HAP and provides the following details:

According to the commenter, Hg CEMS are difficult to maintain and accuracy is questionable at low Hg
levels in conditions seen at utility plants. The commenter states that the NSPS limit is so restrictive that
utility plants cannot meet the proposed limits and control equipment vendors will not guarantee the
limits. According to the commenter, the EPA did not take into consideration the variability of Hg
content in coal when setting the low limits for Hg. The commenter states that in order to represent coal
variation, a better solution would be to use a requirement such as the Illinois Hg removal limit of 90%
which is based on a 720 hour (30-day) rolling average of 1-hour readings and does not rely on a set
maximum limit over 30 days as the proposed limit. According to the commenter, Hg analyzer
performance has been so unpredictable that utility companies that have continued the use of the CEMS
for state requirements are contemplating the replacement of CEMS with sorbent traps for the NESHAP.
The commenter states that the EPA has not publicly released NIST Traceability protocols, and early
elemental Hg Vendor Prime calibrator certifications exhibited poor accuracy and precision.

Response to Comment 6: The EPA disagrees. The EPA does not believe a percent reduction
requirement averaged on a 30-day rolling basis would be more readily monitored than a 30-day rolling
average emission limit. In addition, as stated elsewhere, the EPA questions the legality of a percent
reduction standard in light of court precedent and we do not have sufficient information to set such a
standard even if we believed it was legally available. Sorbent trap monitoring is allowed if a source
owner or operator chooses to use that monitoring option. The interim NIST traceability protocols have
been publically released and represent the results of a collaborative process for establishing protocols
amongst the affected stakeholders for Hg CEMS monitoring.

Comment 7: Commenter 16849 states that there are known limitations to the technologies available to
monitor the surrogate HAPS and provides the following details:

According to the commenter, PM CEMS are difficult to maintain and the NESHAP proposes a
hybridized reference method, mixing EPA Method 5 and 5B. The commenter states that using total PM
for the MACT metals limit surrogate and then setting the filterable PM limit based on the performance
test does not work nor allow for a compliance margin. The commenter states that the NESHAP requires
maintenance of the PM concentration at or below the highest 1-hour average measured during the most
recent performance test demonstrating compliance with the total PM emissions limitation, and the
performance testing for total PM includes both filterable and condensable PM which would establish the
plant or unit limit. The commenter states that since the PM CEMS only measures filterable PM, the
margin of compliance for the unit or plant would be the amount of total condensable PM. The
commenter states that the EPA identifies that EGUs using PRB as a fuel without wet FGD technology

201


-------
have very low condensable PM emissions. According to the commenter, this method establishes an
enforceable limit but does not provide a reasonable margin of compliance and artificially changes the
limit established in the rule. The commenter states that low limits set during initial performance testing
reflect capabilities of new equipment running at steady-state, maximum efficiency, and these conditions
will not be achievable as equipment begins to age. Commenter 16849 requests that the performance test
requirement be removed, using the RATA to verify the CEMS and the CEMS be the compliance
measure based on the 12-month average. According to the commenter, the limit should be set at 0.03
lb/MMBtu, not based on performance testing. Commenter 16849 states that with the addition of PM
CEMS on all units, the requirement for opacity CEMS is no longer needed, and PM CEMS should be
used to demonstrate compliance for opacity.

Response to Comment 7: The final rule adjusts the manner in which PM instruments are used to
determine and monitor filterable PM as an operating limit for non-Hg metals. The rule establishes
emissions testing based on filterable PM only, not total PM. The rule also provides for use of PM
instruments as CPMS. The final rule also does provide for the use of a PM CEMS to determine
compliance with the filterable PM emission limit if the source elects to use this approach (see the final
preamble for further discussion). In that case, the PM CEMS is used as the direct method of compliance
and no additional testing is required other than tests that are required as part of the QA requirements in
PS 11. As for opacity requirements, the EPA disagrees that these MACT standards can undo all prior
opacity standards for EGUs under all programs. The EPA will evaluate the extent to which opacity
monitoring may no longer be needed as it reviews existing federal standards for affected units, including
considering how particular sources choose to operate their PM instruments (e.g., as PM CPMS or PM
CEMS), and will make any appropriate adjustments as part of that future, regular review. States may
wish to consider how instrumentation in this rule could be useful in evaluating requirements for their
own opacity standards.

Comment 8: Commenter 16849 states that there are known limitations to the technologies available to
monitor the surrogate HAPS and provides the following details:

According to the commenter, vendors are not assuring the abilities of HC1 CEMS, and these monitors
have no record in the utility industry. The commenter states that currently no performance test is
available for HC1.

Comment 9: Commenter 17191 states that Table 15 of the docket entry EPA-HQ-OAR-2009-0234 of
the regulation shows that there is no alternative option of using SO2 CEMS data as a surrogate for acid
gas compliance monitoring for existing IGCC units. The commenter states that the only alternative for
compliance is HC1 CEMS installation. Commenter 17191 notes that the HC1 monitoring system is
untested technology for IGCC systems.

Comment 10: Commenter 17402 supports the CEMS requirements outlined in the proposed rule, so
long as the technologies have been proven in the field, like SO2 monitors and Hg sorbent traps, and
unlike filterable PM monitors, continuous Hg monitors, and HC1 CEMS.

Comment 11: Commenter 17677 disagrees with the EPA regarding high frequency emission testing
requirements or PM CEMS due to difficulties in certification at very low emission levels.

Comment 12: Commenter 17757 states that there is no effective CEMS for Hg. According to the
commenter, the HC1 CEMS are not commercially available or adequate for in-stack measurements.
Commenter 17757 disagrees with the EPA establishing CEMS standards about which there is limited

202


-------
experience in the industry and for which the technology has not yet been commercially developed.
Commenters (17757, 19033, 19041) state that it is unclear whether installing and operating CEMS for
the regulated HAP and HAP surrogates eliminates the obligation to also monitor compliance with
operating limits/parameters on control equipment based on a performance stack test. According to the
commenters, a properly installed and calibrated CEMS should suffice. Clarification on this point is
necessary.

Comment 13: Commenter 18023 states that the EPA must provide reasonable continuous compliance
requirements for Hg and other HAP and eliminate requirements for undemonstrated or unreliable
technologies such as HC1 CEMS and PM CEMS.

Comment 14: Commenters 17800 and 17902 state that while CEMS for Hg and PM are available
commercially, EGUs do not have experience in their operation and maintenance on a long term basis.
Hg CEMS are not reliable and require two to three times the effort to maintain as typical SO2 or NOx
CEMS. According to the commenters, further testing and verification of the of the required CEMS
equipment at utility sites need to be conducted before they should be used.

Response to Comments 8 -14: These brief comments raise a variety of issues that generally have been
addressed in response to other more detailed comments. The EPA is maintaining the proposed
requirements to use CEMS where appropriate. If a source owner or operator does not choose to use an
HC1 CEMS in situations where the S02 alternative is not permitted, HF CEMS, or PM CPMS, the rule
provides for a periodic stack testing alternative. If a source owner or operator does not choose to use an
Hg CEMS, the rule provides for a sorbent trap alternative. Apart from PM CPMS, operating parameter
monitoring requirements no longer exist in the rule. The EPA disagrees that Hg CEMS and PM CEMS
are unproven technologies. See response to more detailed comments in other sections of this document
on those issues.

4. Opposition based on operating limit requirements.

Comment 15: Numerous commenters (17197, 17623, 17627, 17716, 17722, 17725, 17731, 17740,
17757, 17770, 17774, 17775, 17776, 17800, 17805, 17816 17820, 17871, 17877, 17885, 17902, 18023,
17913, 18014, 18015, 18031, 18037, 18443, 18539, 19033, 19114, 19122, 19536, 19537, 19538) request
that the EPA remove the operating limit requirements for facilities that utilize CEMS to demonstrate
compliance. According to the commenters, this will reduce the cost and administrative burden of the
rule without sacrificing human health or environmental benefits, and the CEMS will continuously
monitor the level of emissions and document the source's compliance. The commenters state that
requirement to demonstrate compliance in a second form through an operating limit is burdensome and
unnecessary. According to the commenters, the EPA should remove requirements to test for the
underlying pollutants being controlled through a surrogate because such tests are redundant and
unnecessary for compliance with the proposed utility MACT.

Comment 16: Commenters 19120 and 17881 request clarification of the applicability of monitoring and
operating limits to units using CEMS for compliance monitoring.

Comment 17: Several commenters (17730, 17758, 17775) disagree with the EPA requirements for
sources to establish compliance with the non-Hg metal limits using total PM as a surrogate and PM
CEMS as the measurement tool, with the HC1 limit using HC1 CEMS or an SO2 CEMS for ongoing
compliance, or with the Hg limit using a Hg CEMS or a sorbent trap system to also comply with an
operating load limit or with control device operating parameter limits for PM, HC1, or Hg controls.

203


-------
Comment 18: Commenter 17775 states that the EPA provides no data or discussion to justify chosen
control device operating parameters, which are not in most cases sufficiently connected to emissions to
justify imposing enforceable limits.

Comment 19: Multiple commenters (17627, 17740, 17770, 17776, 17816, 18014, 18015) state that the
EPA should amend the regulatory language in section 63.10007(c) to make it clear that fuel sampling
and operating parameter limits do not apply when either all of the regulated HAP or their surrogates are
continuously monitored by a CEMS.

Comment 20: Commenter 19033 recommends that section 63.1008(a) be amended to require
performance fuel analysis tests, if the regulated pollutant or specified surrogate emissions are not
continuously measured by a CEMS.

Comment 21: Commenter 18023 proposes that operating limits should be a trigger for maintenance or
inspection only.

Comment 22: Commenter 17877 states that operating limits or parameters should not be required on
emission control devices where compliance is demonstrated by CEMS and that operating limits should
not be established based on initial performance testing.

Comment 23: Commenter 17928 states that stack testing is unnecessary to assure compliance if a unit
installs or uses CEMS.

Response to Comments 15 - 23: The final rule clarifies that where a CEMS is used for a given
pollutant (including an alternate equivalent standard in the case of SO2) then no parameter monitoring is
also required for demonstrating continuous compliance with the emission limit for the applicable
pollutant. The final rule also clarifies that sources do not have to test for a pollutant where the source is
meeting a surrogate emission standard (such as filterable PM for non-Hg HAP). As mentioned in other
responses, with the exception of PM CPMS and in limited cases, site-specific parameters for liquid oil-
fired units, the remaining fuel analysis, operating limit and parameter monitoring comments, are moot,
for the rule no longer requires operating limits. For the EPA's response to those comments which
oppose the manner in which operating parameter limits are set, please see responses to comments under
section 5A05 in this document. As noted elsewhere, no operating parameter requirements apply when a
CEMS is used to demonstrate compliance for an applicable pollutant.

5. Opposition based on averaging times.

Comment 24: Commenter 16849 recommends that averaging times for demonstrating compliance with
the Hg limits be increased to a 365-day rolling average due to variability in coal quality, varying Hg
content, removal equipment, and Hg CEMS monitor accuracy.

Comment 25: Commenter 17197 supports the proposed "30-boiler operating day rolling average"
calculation methodology based on averaging all of the valid hourly averaged measurements during the
preceding 30 boiler operating days. According to the commenter, if compliance is based on daily periods
rather than hourly periods, a single (abnormally high or low) hourly measurement could be the basis of a
daily period that could improperly bias the resulting 30-day average. The commenter states that using
hourly averages as the basis for the 30-day boiler operating day rolling averages removes the potential
for skewed results from days containing only a few unit operating hours and consequently yields
representative emission rates for the 30-day compliance demonstration period.

204


-------
Comment 26: Commenter 17740 does not support compliance demonstration with the tested average
PM value using a 30-boiler operating day PM average.

Comment 27: Commenter 17402 states that since the rule does not propose a cap-and-trade program,
units should not be required to collect a monitored value for each operating hour.

Response to Comments 24-27: The final rule maintains the 30-day rolling average using hourly
values (unless a source chooses to apply emissions averaging of Hg emissions for multiple units in the
EGUs designed for coal > 8,300 Btu/lb subcategory). This averaging period enables short-term
variability to be averaged out, and this averaging period is consistent with the periods already used in
subpart Da of the NSPS. Sources are required to monitor during all operating periods when continuous
monitoring is used to demonstrate compliance. See the preamble for discussion of alternative averaging
times.

6.	Opposition based on bias adjustments.

Comment 28: Several commenters (17881, 17796, 18023) support eliminating the bias adjustment for
mercury, HC1, and PM CEMS since it is believed that bias adjustment of data has only been utilized
with trading system based rules where mass emissions are being totaled.

Comment 29: Commenter 18023 states that bias can cause both over-and-under reporting. The longer
averaging time should alleviate the need for bias adjustment.

Comment 30: Commenter 17767 states that unless the EPA is prepared to allow for the low bias of
emissions data as well as high, it is best to follow the proposed rule and remove the Part 75 Bias Test for
Hg, HC1, and PM CEMS.

Response to Comments 28 - 30: There is no bias adjustment factor applied for purposes of this rule.

7.	Opposition based on compliance requirements.

Comment 31: Commenter 16849 disagrees with the EPA about the ability of Hg CEMS to reach
compliance within the first 30 days of operation. According to the commenter, with the needed
adjustments and repairs to Hg CEMS and the additional operation of multiple control devices, plant
personnel will need at least 180 days to optimize control and monitoring equipment.

Response to Comment 31: For existing units, the final rule requires sources to demonstrate compliance
within 180 days after the date 3 years after the effective date of the final rule. Such an extended period
provides ample opportunity for the types of adjustments suggested by the commenter. For new units, the
rule likewise provides up to 180 days for demonstrating initial compliance.

Comment 32: Commenter 17716 disagrees with the EPA about showing on-going compliance by
combining CEMS data with non-CEMS data to demonstrate compliance.

Response to Comment 32: The comment is moot, as the rule no longer contains a total PM limit, no
longer requires use of PM CEMS for filterable PM, and no longer requires use of Method 202 to
determine condensable PM.

205


-------
Comment 33: Commenter 17758 states that the purpose of the fuel input limits is to ensure that EGUs
that are not using CEMS or sorbent trap monitoring systems repeat the relevant performance test if their
fuel characteristics change such that compliance with the applicable limit at the current level of control
is no longer assured. According to the commenter, since all EGUs are required to demonstrate initial
compliance with each emissions limit through performance testing, and the proposed rule defines
performance testing to include the first 30 operating days of CEMS data, the proposal appears to require
that EGUs meet fuel input limits regardless of the performance testing option that they choose. The
commenter states that there is no logical rationale for requiring sources that establish compliance with
the non-Hg metal limit using PM as a surrogate and PM CEMS, with the HC1 limit using HC1 CEMS or
an S02 CEMS, or with the Hg limit using Hg CEMS or a sorbent trap system to also comply with fuel
input limits for metals, chlorine or Hg.

Response to Comment 33: The comments are moot because the rule no longer requires fuel analysis or
operating limits.

Comment 34: Commenter 17775 notes that the EPA does not propose separate continuous compliance
requirements for HF CEMS.

Response to Comment 34: Section 63.10010(d) addresses operating requirements for HF CEMS.

Comment 35: Several commenters (17800, 18015, 18037) state that compliance testing and monitoring
requirements that include periodic emission testing, other performance testing and CEMS are
unnecessarily restrictive and expensive to implement, perform and operate. According to the
commenters, the regulations for Hg CEMS had numerous unresolved issues related to accuracy,
calibration standards, and quality assurance provisions, and the EPA should allow time for development
of performance specifications and, field testing and verification of the accuracy and precision
of HC1 monitoring equipment at utility sites before they are required for compliance purposes.

Response to Comment 35: For comments on technical aspects of HC1 and Hg monitoring, see the
specific responses to comments on those technologies in other sections of this document. The EPA
disagrees with granting states flexibility to establish compliance plans for sources. This is a federal rule,
which provides flexibility to sources to select appropriate monitoring for their facility. In the event the
source believes an alternative monitoring method should apply, the part 63 provisions establish a
method to request alternative monitoring, and the EPA and the states have established procedures for
handling such requests in the event implementation of a specific NESHAP is delegated to a state agency.

Comment 36: Commenters 17805 and 17816 state that there is no logical reasoning for requiring
sources to establish parametric limits for compliance at units already demonstrating compliance
with CEMS.

Response to Comment 36: The comments are moot because the rule no longer requires fuel analysis or
operating limits.

Comment 37: Commenter 17856 states that due to the very low concentrations of Hg in stack gases,
any little flaw in the precision or accuracy of the monitor could lead to an inaccurate compliance
determination. The commenter states that the uncertainty associated with the use of these technologies
further illustrates the need for provisions within the rule allowing a state to develop compliance plans
tailored to a particular unit's operations. According to the commenter, states need monitoring
requirements with flexible options for compliance plans, such as fuel sampling and analysis, emission

206


-------
control monitoring, and the installation of CEMS, to provide sufficient assurance that actual emissions
limits are being met.

Response to Comment 37: For comments on technical aspects of HC1 and Hg monitoring, see the
specific responses to comments on those technologies in other sections of this document. The EPA
disagrees with granting states flexibility to establish compliance plans for sources. This is a federal rule,
which provides flexibility to sources to select appropriate monitoring for their facility. In the event the
source believes an alternative monitoring method should apply, the part 63 provisions establish a
method to request alternative monitoring, and the EPA and the states have established procedures for
handling such requests in the event implementation of a specific NESHAP is delegated to a state agency.

Comment 38: Commenter 17881 states that the EPA needs to clarify whether fuel analysis and/or the
establishment of operating limits apply in those cases where a CEMS is used to directly measure
the HAP or an associated surrogate.

Response to Comment 38: The comments are moot because the rule no longer requires fuel analysis or
operating limits.

8. Opposition based on monitoring requirements.

Comment 39: Commenter 17740 recommends that the EPA eliminate fuel sampling and parameter
monitoring for an EGU which meets the specified emission limits as demonstrated through use of a
CEMS and states the following:

a.	The EPA has not provided a rational justification for additional requirements to Part 75. See 40 CFR
section 63.10010.

b.	The EPA should allow at least 1 year for sources to install and certify an HC1 CEMS and should
require HC1 testing once every four unit operating quarters, but no less than once every eight calendar
quarters.

Comment 40: Commenter 17758 states that the EPA does not have a performance specification that is
specific for non-FTIR-based HC1 monitors. The commenter states that table 5 of the docket entry EPA-
HQ-OAR-2009-0234 lists PS 6 as an applicable performance specification, but PS 6 is written for the
certification of systems used to measure pollutant emissions in units of mass per unit of time. The
commenter states that the EPA protocol gases are not widely available and are expensive relative to
traditional CEMS calibration gases. According to the commenter, lowest available concentrations are
significantly higher than proposed limits. Commenter 17758 recommends that the EPA allow use of SO2
monitors installed downstream of a wet or dry scrubber or DSI system to comply with the HC1
monitoring requirements.

Comment 41: Commenter 17775 states that the EPA should describe why EGUs need to monitor
control device parameters for meeting fuel input levels and that there is no discussion at all of the
proposed fuel input levels in the docket entry EPA-HQ-OAR-2009-0234.

Response to Comments 39-41: As stated elsewhere in response to more detailed comments, source
owners or operators who use CEMS to demonstrate continuous compliance are not required to monitor
operating parameters or fuel for the same pollutant, as fuel analysis is no longer required and, apart from
PM CPMS, operating limits are no longer required. A source can opt to use an SO2 CEMS instead of an

207


-------
HC1 CEMS in specific circumstances, and can use emissions testing in lieu of an HC1 CEMS. The EPA
also intends to promulgate a performance specification for HC1 CEMS prior to the compliance date of
this rule, at least with respect to the compliance date for existing sources.

Comment 42: Commenters 17716 and 18449 state that section 63.1002l(a)(10)(ii) does not include a
reference to CO2 contrary to the requirements in section 63.10010(b) which allow the use of O2 or CO2.
According to the commenters, the majority of Part 75 affected coal-fired units utilize dilution-
extractive CEMS which are equipped with CO2 analyzers, and dilution-extractive CEMS cannot
measure O2 as a diluent.

Response to Comment 42: The final rule addresses this oversight.

Comment 43: Commenter 17881 states that in cases where an EGU elects to calculate annual Hg
emissions based upon the average measured Hg concentration and measured exhaust flow rate, the EPA
has already granted the use of the default moisture content values for the determination of exhaust gas
moisture content in 40 CFR part 75, section 75.11(b)(1).

Response to Comment 43: The final rule allows for moisture defaults as proposed. Given the lack of
defaults for oil-fired units, we have added an option for sources to petition for an alternative unit-
specific default in those cases.

Comment 44: Commenters 17881 and 19114 state that the proposed regulation referring to "fuel-
specific CO2 concentration" in section 63.10005(1) has following flaws:

a.	According to the commenters, the proposed rule does not contain any such default CO2 concentration
values and does not reference another regulation containing such values, and it is hard to believe that the
EPA intended for each regulated source to develop a custom "fuel-specific CO2 concentration" based
upon the equivalent O2 diluent cap and the fuel or fuels being fired.

b.	According to the commenters, these provisions do not distinguish between boilers and the combustion
turbines used in IGCC technologies; boilers and combustion turbines are fundamentally different
combustion processes and operate at very different levels of excess air (which in turn impacts

the diluent gas concentrations).

c.	According to the commenters, the proposed rule language is not clear on when the diluent cap values
should be applied; it simply states that they should be applied during periods of startup and shutdown
(which are not defined in the proposed rule, and are only generically defined in section 63.2). The
commenters state that under 40 CFR Part 75, the diluent cap values are simply applied whenever the 1-
hour average diluent concentrations fall below the applicable diluent cap values (without any
qualification that the unit must be in startup or shutdown modes). Outside of periods of startup and
shutdown, state the commenters, it is hard to envision any other circumstances which would cause

the diluent concentrations to fall below the diluent cap values.

Response to Comment 44: Given the changes from proposal, these provisions are no longer relevant
and do not appear in the final rule.

Comment 45: Commenter 18014 states that EGUs that install a CEMS should not be required to
provide further assurance of compliance with the emissions standards. According to the commenter,

208


-------
such additional monitoring is redundant and creates an unnecessary burden on these sources and as such
should be removed from the rule.

Response to Comment 45: The EPA agrees, and the final rule clarifies this approach.

9.	Opposition based on QA/QC requirements.

Comment 46: Several commenters (17716, 17881, 18014) state that the O2 and CO2 CEMS
requirements in section 60.10010(b) should refer to 40 CFR Part 75 in lieu of the alternate requirements
specified in Appendix A to subpart UUUUU of the docket entry EPA-HQ-OAR-2009-0234. According
to the commenters, the following text should be added to Table 5 of the docket entry EPA-HQ-OAR-
2009-0234, as applicable: "Alternatively, for an affected source that is also subject to the O2 or CO2
monitoring requirements of 40 CFR Part 75 of this chapter, the owner or operator may install, certify,
maintain, operate and quality assure the data from an O2 or CO2 CEMS according to 40 CFR Part 75 in
lieu of the procedures in paragraphs b(l) through b(3) of this section."

Response to Comment 46: The final rule includes language comparable to the requested language for
an O2 or CO2 CEMS. For the SO2 CEMS, see responses to similar comments under 5A08 of this
document.

Comment 47: Commenter 17716 disagrees with the EPA about additional QA/QC requirements for use
of S02 CEMS. The commenter states that although use of S02 CEMS is allowed for compliance
demonstration, the requirements state that the operator "must perform the 7-day calibration error test
required in Appendix A to 40 CFR Part 75 on the S02 CEMS whether or not it has a span of 50 ppm or
less." According to the commenter, because the majority of 40 CFR Part 75 affected sources have
completed initial certification years ago and have been collecting "quality-assured" data for years, the
benefit to this requirement is not apparent.

Response to Comment 47: This requirement has been removed in the final rule based on comments,
and we do not think it is appropriate to include the provision pending further review of the technical
issue by EPA's monitoring groups.

Comment 48: Commenters 17820 and 17821 state that there are already other monitoring requirements
for units required to report under Part 60, and there have been attempts to harmonize those rules to
reduce confusion and cost. According to the commenters, the Part 60 rules, like these proposed rules, are
not as detailed as Part 75 and could lead to inconsistencies in data quality between operators. Adding
additional, different, and possibly conflicting requirements for this rule will cause additional confusion,
increase downtime, and increase costs with no evidence of any benefit.

Response to Comment 48: The EPA has attempted to harmonize the CEMS requirements under this
rule primarily with the Part 75 CEMS requirements that already apply to most of the affected EGUs
under this rule.

10.	Opposition based on sampling.

Comment 49: Commenter 17316 states that the outlet location for CEMS Probe is not the best location
for these probes. The commenter states that the "outlet location" defined as the immediate exit of the
boiler, just downstream of the combustion process, is not an appropriate location where a "representative

209


-------
sample" can be collected. Commenter 17316 recommends that "representative samples" should be
obtained by locating the probe in the downstream ductwork or in the stack.

Comment 50: Commenter 17655 states that the monitoring requirement for three new monitoring
devices in existing smoke stacks threatens stack integrity and adds that the EPA did not consider safety
issues associated with drilling additional holes in existing stacks and chimney liners.

Comment 51: Commenters 17775 and 17928 disagree with the EPA requirement for HAP stack testing
for EGUs using surrogates, surrogate stack testing for EGUs using CEMS, and surrogate testing for
EGUs not relying on surrogates for compliance demonstration.

Response to Comments 49-51: In response to comments, the final rule has removed all requirements
for duplicative testing of a HAP and the applicable surrogate. Facilities complying with a surrogate
standard will conduct the performance test for that standard, and not for the corresponding HAP
emission limit (and vice versa).

Comment 52: Commenter 18014 states that it is unclear as to whether EGUs that fire a single type of
fuel are exempt from all fuel sampling and analysis requirements.

Response to Comment 52: This comment is moot because the fuel analysis requirements are not
included in the final rule.

Comment 53: Commenter 17902 states that installation of additional CEMS for PM and HC1 requires
significant structural modifications, such as:

a.	Installation of additional ports (to install the sampling probe);

b.	Stack platforms (additions or modifications to existing platforms to access new monitoring
equipment);

c.	Shelters (to house climate controlled equipment);

d.	Electrical instrumentation (to power shelters, heat probes, etc); and,

e.	Communications systems (needed fiber optics, Ethernet to communicate with existing computer
programs).

Response to Comment 53: The addition of new monitoring equipment may require additional
modifications to existing CEMS infrastructure, although the EPA questions whether the changes are
significant structural modifications in light of the emission control requirements of this rule. To the
extent a source believes these changes are too significant, the source can conduct periodic stack testing
as an alternative to either a PM CPMS or an HC1 CEMS.

11. Need clarification on operational limitations.

Comment 54: Commenter 17800 states that the compliance with MACT standards that have numerical
limits should be based on what is being measured in the stack and not on how the unit is being
operated. Use of CEMS should preclude operational limits. According to the commenter, the operational
requirements in Table 4 of part 63 subpart UUUUU are unnecessary, requiring unneeded record keeping

210


-------
that does not improve compliance and should be eliminated from this rule. The commenter states that if
the unit chooses to install and properly operate and maintain CEMS for filterable PM, Hg and HC1, these
operating limits are unnecessary. According to the commenter, once the CEMS are certified and
recording quality assured data, these systems determine the unit's compliance status. The commenter
states that the EPA should clarify when CEMS are being used for compliance, operational limitations on
unit load and the applicable control equipment are unnecessary as well as the reporting requirements in
section 63.10031 pertaining to those operational requirements.

Response to Comment 54: Where a CEMS is used, EPA largely agrees. As discussed in detail
elsewhere in this response to comments document, EPA has eliminated all operating limits in Table 4,
with the exception of an operating limit associated with a PM CPMS, and in limited cases, site-specific
parameters for liquid oil-fired units. In consideration of the PM emissions limit and the burden
associated with certifying a PM CEMS via PS11, the agency decided to allow use of a PM instrument
not as a CEMS but as a CPMS. The operating limit for use in conjunction with a PM CPMS functions in
the same manner as parameter monitoring from other rules. The highest hourly average of the PM
CPMS signal produced over three test runs is used as the operating limit, and that value becomes
averaged over a rolling 30 boiler operating day average. The final rule also does provide for the use of a
PM CEMS to determine compliance with the filterable PM emission limit if the source elects to use this
approach (see the final preamble for further discussion). In that case, the PM CEMS is used as the direct
method of compliance and no additional testing is required other than tests that are required as part of
the QA requirements in PS 11.

12. Requirements for bypass stacks.

Comment 55: Commenter 17718 states that within the proposed regulatory language of
section 63.10006, there does not appear to be an option for reduced HC1 performance testing
requirements on coal-fired units with non-HCl controlled bypass stacks. The commenter states that
within the proposed language of section 63.10010(a)(4), it appears that a bypass stack would be required
to install similar monitoring systems as the main common stack. According to the commenter, without
flue grade sulphurization technology on the bypass stack, it appears that the current 40 CFR Part 75 SO2
CEMS located on the bypass stack could not be used for compliance determinations as a surrogate
for HC1. The commenter states that even if the company desired to install an HC1 monitor on the dry
stack to monitor emissions, it would still be required to conduct performance testing every month.

Comment 56: Commenters 17772 and 17873 state that PM CEMS do not operate properly during
startups and shutdowns. According to the commenters, PM CEMS are not calibrated under startup or
shutdown conditions, nor are they calibrated using the changing fuel mix (e.g., moving from 100 percent
oil to 100 percent coal) associated with start-up, and values during these times are not valid for
compliance purposes. If a bypass stack is predominately used during startup and shutdown, state the
commenters, there should be no requirement to install a PM CEMS. The commenters state that the EPA
has the discretion necessary to regulate PM through a work practice standard; instead of requiring costly
and duplicative monitoring equipment to measure intermittent emissions that occasionally flow through
bypass stacks, the EPA should develop work place standards that would put parameters around how
often and when bypass stacks can be employed.

Comment 57: Commenter 17781 states that the periods of EGU startup and shutdown resulting
in FGD bypass, as well as reasonable periods of FGD malfunction which are addressed in an appropriate
manner, should not disqualify an EGU from using the SO2 surrogate for HC1.

211


-------
Response to Comments 55-57: The final rule provides an option to monitor a bypass stack or to treat
any hour in which the unit bypasses the main stack and fails to collect quality-assured data as an hour of
monitoring downtime. The EGU owner or operator remains subject to the 30 boiler operating day rolling
average during bypass operations.

13.	Opposition based on maintenance requirements.

Comment 58: Commenters 17775 and 17800 state that the EPA did not account for the fact
that EGUs need to perform maintenance, in addition to required QA/QC, in order to keep monitoring
systems running properly. The commenters state that the EPA should recognize this in the 40 CFR part
63 general provisions, which require sources to maintain their monitoring systems and exempts
"maintenance periods" from operating requirements.

Response to Comment 58: Normal maintenance activities associated with quality control (not quality
assurance) procedures in a source's monitoring plan are exempt as part of the QC exemption provided in
the final rule. No additional exemption is necessary.

14.	Need for clarification on monitoring, recordkeeping and reporting requirements.

Comment 59: Commenter 17776 states that the EPA needs to clarify the proposed rule that monitoring,
recordkeeping, and reporting requirements do not apply for facilities equipped with CEMS. According
to the commenter, facilities which use CEMS for monitoring of a regulated pollutant or surrogate should
not require fuel sampling, parameter monitoring, or compliance with fuel or operational limits.

Response to Comment 59: The rule does not require monitoring operating limits where a CEMS is
used for the applicable standard. If a source has PM control equipment and uses a PM CPMS-based
operational limit, no control device monitoring is required. The same is true for SO2/ HC1 controls.

Comment 60: Commenter 17776 states that for PM (Item 1) and HC1 (Item 3) in Table 5, references to
Appendix A of subpart UUUUU in the "using" column are listed, but Appendix A of
subpart UUUU does not address monitoring certification and ongoing monitoring requirements for PM
and HC1 CEMS.

Response to Comment 60: These cross references have been corrected in the final rule.

Comment 61: Commenter 17725 states that the EGU MACT Rule does not include provisions to use
the Part 75 "conditionally valid data procedures." The commenter states that if a CEMS fails a linearity
check, the CEMS remains out-of- control until the successful completion of a subsequent linearity
check, and this would require the operator to invalidate the Part 75 conditionally valid data (for SO2,
CO2, O2 or flow monitors) for the EGU MACT recordkeeping and reporting purposes. According to the
commenter, a clearer approach would be to allow quality-assured data from a CEMS certified and
operated in accordance to Part 75 to be used for EGU MACT compliance.

Response to Comment 61: The final rule provides for certain Part 75 procedures for the CEMS and
sorbent trap monitoring systems used to comply with this rule, including the use of the conditionally
valid data procedures.

15.	Lack of variability.

212


-------
Comment 62: Commenter 18014 states that the snapshot nature of performance test data means the
results will provide little insight on the true range of boiler variability and the associated effects on
emission controls. According to the commenter, the EPA should address the additional variability
introduced by the CEMS within the rule. The commenter states that the "apples-to-oranges" contrast of
the CEMS versus reference method data (particularly given the current state of PM, HC1 and Hg CEMS)
provides additional support to use the CEMS data as indicators of performance rather than direct
measures of compliance. According to the commenter, since neither the CEMS measurement variability
or the plant operational variability that will be an inherent part of the CEMS data will not be reflected in
the reference method-based UPL, a separate multiplier should be applied to the UPL (or applied as an
additional multiplier to the FVF adjusted floor average) to address for the CEMS/operating variability
issue.

Response to Comment 62: The PM monitoring will be used as a PM CPMS and not as a direct
compliance method with an emission limit. For the Hg CEMS or sorbent trap monitoring system, and
the HC1 CEMS, the EPA disagrees. This issue is discussed in more detail in the comment sections
directly related to Hg CEMS and HC1 CEMS.

16.	Missing information.

Comment 63: Commenter 18014 states that the rule does not include the equations for calculating PM
or HC1 mass emissions; Appendix A only includes equations for Hg.

Response to Comment 63: There is no requirement to calculate PM mass emissions; PM monitoring is
a parameter-based approach to ensure compliance with an operating limit. For HC1, section 9 of
Appendix B to the final rule provides the appropriate method for calculating emissions in terms of the
emission standard.

17.	Recommendations.

Comment 64: Commenter 15678 recommends that CEMS need to be certified and recertified according
to the EPA proposed procedures, such as Table A-l on page 25140 of the Federal Register (Vol. 76, No.
85 / Tuesday, May 3, 2011) for the required certification tests and performance specifications for Hg
CEMS.

Comment 65: Commenter 16849 recommends that further testing and verification of the accuracy of the
required CEMS equipment at utility sites be conducted before they are used for compliance purposes.

Comment 66: Commenter 17191 recommends that the SO2 monitoring as a surrogate for acid gas HAP
be included as an option for IGCCs as it is for other categories that have SO2 data available.

Comment 67: Commenter 17197 recommends that a footnote be added to Table 5 of the docket entry
EPA-HQ-OAR-2009-0234 that states "Daily calculate a new 30-boiler operating day rolling average of
all of the hourly CEMs emissions data for the preceding 30-boiler operating days."

Comment 68: Commenter 17265 is requesting clarification of whether CEMS are warranted across-the-
board for the HC1 source category, and supports retaining a source's option to select CEMS as the
monitoring method, but recommends that the QA provisions be further developed to ensure the
credibility and accuracy of the data.

213


-------
Comment 69: Commenter 17283 recommends proposed alternative standards for total or individual
metals, including specific language in the final rule allowing enhanced monitoring of these metals with
multi-metals CEMS as an alternative to Reference Method 29 measurements and/or PM CEMS and/or
Hg CEMS.

Comment 70: Commenter 17283 states that cycle time equal to or less than 15 minutes is currently
required for CEMS in various places (Table A-l, Table A-2, and pages 25110-25113) of the docket
entry EPA-HQ-OAR-2009-0234 and strongly recommends that these references to 15-minute cycle
times be eliminated because, according to the commenter:

a.	15-minute cycle times are not required to evaluate health effects or demonstrate compliance with
limits,

b.	Reference methods require sampling times of about 4 hours at these low concentrations, and

c.	The proposed cycle time is not consistent with PS12 A or Cement MACT rules.

Comment 71: Commenter 17283 recommends that units employing PM CEMS should be exempted
from federal and state opacity monitoring requirements.

Comment 72: Commenter 17677 recommends that the EPA must have certifiable methods for source
CEMS in order to determine accuracy. According to the commenter, without certifiable
methods/procedures, data accuracy cannot be relied upon for compliance determinations.

Comment 73: Commenter 17677 recommends that the EPA clarify the language relating to initial
compliance demonstrations for CEMS.

Comment 74: Commenter 17730 recommends that the EPA should provide procedures for averaging
actual emissions data from CEMS to determine monthly average weighted emissions and revision of
section 63.10009 to include procedures for units using CEMS to calculate average weighted emissions
in lieu of compliance with the operating limits for control devices proposed in section 63.10022.

Comment 75: Commenter 17681 recommends that the EPA should allow compliance to be
demonstrated based on stack tests and CAM plans.

Comment 76: Commenter 17638 recommends that the EPA allow compliance to be demonstrated based
on stack tests and CAM plans other than PM and HC1 CEMS.

Comment 77: Commenters (17716, 18014) recommend that the EPA should revise section 63.10007 to
indicate that the fuel sampling and operating parameter limits are not required when the applicable HAP
(or surrogates) are monitored using a CEMS.

Comment 78: Commenter 17731 concurs that the performance stack testing requirements set out in
Table 5 (part 76 CFR 25129-31) should not be required of those EGUs that use CEMS for continuous
compliance because the requirements are redundant and burdensome without providing added benefit.

Comment 79: Commenters (17767, 17881, 18428) recommend that it is appropriate that the proposed
rule does not require the generation and submittal of missing data substitutions, as the emissions
limitations are rate-based and not mass-based.

214


-------
Comment 80: Commenter 17775 recommends that the EPA should allow use of 40 CFR Part 75
provisions as an alternative for diluent monitoring.

Comment 81: Commenter 17775 recommends that the EPA revise section 63.10010(a) to acknowledge
the other monitoring options in the rule (including the option of stack testing with monitoring of
operating parameters and, fuel analysis for liquid oil-fired units), or limit applicability of the section to
those circumstances where an EGU opts to, or is required to install a CEMS or sorbent trap system.

Comment 82: Commenter 17775 recommends that the EPA should eliminate the redundancy between
section 63.10010(a)(4) and Appendix A section 2.

Comment 83: Commenter 17775 recommends that the EPA include provisions similar to 40 CFR Part
75 that allow EGUs that are otherwise using CEMS to report a site-specific default value during bypass
in lieu of installing and maintaining CEMS on the bypass stack.

Comment 84: Commenter 17776 recommends that the EPA should revise the requirement to use
PM CEMS for demonstrating continuous compliance with the total PM limit. PM CEMS can only
analyze for filterable PM per EPA PS 11.

Comment 85: Commenter 17776 recommends that the EPA should allow the use of sorbent trap
monitoring systems as another means for continuous monitoring of Hg emissions. Commenter also
recommends that the EPA allow annual performance tests for HC1 until HC1 CEMS technology
advances further.

Comment 86: Several commenters (17725, 17820, 18014, 19033) recommend that section
63.10010(b)(5) should be revised to include C02, for example, "the average of all of the hourly oxygen
or carbon dioxide emissions data for the preceding 30 boiler operating days," and that section
63.1002l(a)(10)(ii) should include a reference to CO2 records.

Comment 87: Commenters (17718, 18037, 18539) recommend that performance testing should be
conducted annually for each of the stacks instead of every other month as currently proposed. According
to the commenters, it may not be feasible to complete testing at all units within a monthly or 2-month
period due to lack of test crews, unit scheduling, scheduled maintenance, and other considerations.

Comment 88: Commenter 17722 states that the EPA should allow "to-be-approved" monitoring
techniques and technologies as part of the final rule. As one example, Commenter is aware of a
novel sorbent tube technology that is under development by the University of North Dakota's Energy
and Environmental Research Center ("EERC"), where the sorbent tubes are designed to measure HAP
acid gases and non-Hg HAP metals. According to the commenter, EERC is under contract with the
Department of Energy to run parallel Method 26 and Method 29 tests later this year, and if
these sorbent tubes prove viable, like Hg sorbent tubes, the final EGU NESHAP rule should allow use of
this new approved monitoring technology.

Comment 89: Commenters 17821 and 17881 recommend removal of requirements for calculating (and
reporting) long-term 30-day rolling averages for O2 (and CO2) emissions. O2 (and CO2) concentration
data are typically used as a diluent gas when using CEMS measurement data to calculate emission rates
in terms of lb/MMBtu. According to the commenters, the diluent gas components of these equations
under 40 CFR 60 are not averaged into long-term averages; only the emission rate data (lb/MMBtu) are
averaged over long-term periods, and these long-term emission rate averages are calculated not from

215


-------
long-term O2 or CO2 averages and long-term SO2 or NOx averages, but from the hourly emission rate
data that is calculated using the hourly diluent gas values.

Comment 90: Commenter 17821 recommends that the EPA allow the use of certified flow monitoring
systems to calculate emissions rates when volumetric flow rate is needed. The commenter states that
volumetric flow CEMS certified in accordance with 40 CFR 75 are used for reporting purposes already
and allowing these data to also be used to calculate mass emissions would provide consistent data.

Comment 91: Commenter 17881 states that the provisions at section 63.10010(b)(4) require that
CEMS data be reduced to 1-hour averages according to the requirements in section 63.8(g)(2) and (4).
According to the commenter, these data reduction procedures are not fully consistent with the
procedures specified at section 60.13(h) and section 75.10(d)(1), and commenter suggests that the
preceding data reduction procedures be allowed as alternatives to those which are currently specified.

Response to Comments 64-91: The EPA has considered all of these various recommendations in
finalizing the proposed monitoring requirements. In general, the final rule builds on the proposed
requirements by providing for monitoring continuous compliance with specific standards through the
use of an applicable CEMS, or a sorbent trap for Hg, or a PM CPMS for non-Hg metals or PM. Should a
source owner or operator elect not to use CEMS or the other instrumental methods, performance testing
is required. In revising the proposed rule, the EPA has finalized an approach that builds off the Part 75
requirements wherever possible for CEMS. The EPA believes that the initial and ongoing certification
and QA procedures for applicable CEMS are appropriate for ensuring the collection and reporting of
quality data. The final rule includes a variety of specific changes to help clarify the use of CEMS versus
operating parameter monitoring, calculation of 30-day rolling averages, and other specific issues with
the monitoring requirements raised in these brief recommendations and more specific comments on
aspects of the proposed standards. Where a source owner or operator wishes to use an alternative
monitoring approach, such as a multi-metals CEMS, the source owner or operator may propose such a
method under the general provisions in section 63.8(f) of subpart A of part 63.

18. Need for clarifications of rule.

Comment 92: Commenters 17718 and 17881 request that the EPA clarify when the 30-day operating
period begins if the systems are already certified (e.g., current SO2 or PM CEMS being used for
40 CFR Part 75 and/or 40 CFR Part 60 monitoring programs).

Response to Comment 92: The 30-day period will begin on such date as you indicate in your
Notification of Intent to conduct a performance test (see section 63.10030(d)). You must complete the
initial test within the period specified in the rule.

Comment 93: Commenter 17718 states that the EPA should clarify whether initial testing of the bypass
emissions needs to be tested within the 180-day timeframe described in the proposed language and that
alternatively, setting a firm testing timeframe on bypass stack emissions seems overly burdensome.
According to the commenter, creating emissions (and incurring costs) by switching a unit into bypass
mode that would not otherwise have been used simply in order to perform emission testing appears to
create unnecessary burden.

Response to Comment 93: Under the final rule, you may elect to monitor the bypass stack or treat
hours in which the bypass is used as monitor downtime. The EGU owner or operator remains subject to
the 30 boiler operating day rolling average during bypass operations. To report data from any

216


-------
monitoring on a bypass stack, you do need to have a certified monitoring system. Because you can
decide to not monitor the stack, there is no requirement that the certification occur in the first 180
operating day period.

Comment 94: Commenters 17718 and 19121 states that in the proposed regulatory language seen in
section 63.10005(1), it is mentioned that a "default diluents gas concentration value of 10.0 percent O2 or
the corresponding fuel-specific CO2 concentration" are to be used during periods of startup or shutdown
when calculating emissions in units of "lb/MMBtu" or "lb/TBtu." According to the commenter, the EPA
should clarify how to calculate the "corresponding fuel-specific CO2 concentration."

Response to Comment 94: Because of the revisions related to startup and shutdown provisions, the
cited language is no longer applicable.

Comment 95: Commenter 17820 cites that Table 8 states that the source is to convert "hourly emissions
concentrations to 30 individual boiler operating mg/dscm values," which suggests that compliance is
assessed based on the average of 30 individual daily values but that section 63.10010(g)(5) states that
30-day rolling average is calculated as "the average of all of the hourly particulate emissions data for the
preceding 30 boiler operating days." The commenter states that this requirement needs to be clarified.

Response to Comment 95: The referenced language in the proposed rule is not used in the final rule.
Provisions in Appendix A and Appendix B to the final rule describe the procedure for calculating 30-day
averages where an Hg CEMS, sorbent trap monitoring system, or HC1 CEMS are used for compliance.
Overall, the language in the final rule ensures a uniform approach for calculating averages from CEMS
data and from a PM CPMS.

217


-------
5A11 - Testing/Monitoring: Disable bias tests for Hg, HC1, and PM CEMS
Commenters: 17718, 17740, 17816, 17820, 17873, 17877, 17881, 17909

1.	Support for eliminating bias tests.

Comment 1: Multiple commenters (17718, 17740, 17816, 17820, 17873, 17877, 17909) recommend
that the EPA disable the ECMPS Part 75 bias test for Hg, HC1, and PM CEMS. The commenters state
that bias adjustment may be appropriate for emissions trading programs to ensure that companies are not
under-reporting their emissions and, hence, failing to surrender an adequate number of allowances for
compliance purposes, but it is unnecessary for compliance with the MACT standards.

Comment 2: Commenters 17718 and 17816 support the EPA's proposed approach to streamline the
continuous compliance requirements for monitoring, reporting, and recordkeeping and urge the EPA to
remain open to additional accommodations that are identified in the course of implementing the
program.

Comment 3: Commenter 17877 states that eliminating the bias test for these monitors will also reduce
the file size, complexity, and time required to maintain and report quality assured data.

2.	Other bias test comments.

Comment 4: Commenter 17881 states that the proposed EGU MACT rule appears to be silent on the
concept of whether SO2 missing data substitution under 40 CFR Part 75 would be allowed in the context
of 63.10010(e)5. In addition, states the commenter, the concept of bias adjustment factors (BAFs) under
40 CFR Part 75 does not appear to be addressed. According to the commenter, in other cases where the
EPA has allowed the use of Part 75 CEMS for compliance demonstrations under other regulatory
programs (i.e., 40 CFR Part 60, subpart Da), the EPA has prohibited the use of missing data substitution
and BAFs.

Response to Comments 1 - 4: As suggested in the proposed rule, the final rule does not require any bias
adjustment when reporting data under this rule. For missing data related comments, see responses to
comments under Comment Code 5A12.

218


-------
5A12 - Testing/Monitoring: CEMS monitor out-of-service versus missing data substitution
Commenters: 17316, 17620, 17655, 17818, 17821, 17877, 17881, 17886, 17904, 18023

1.	Agrees that there is no need for missing data substitution.

Comment 1: Several commenters (17655, 17877, 17904) agree with the EPA that there is no need for
missing data substitution procedures in this monitoring scheme. According to the commenters, missing
data routines are unique to those programs that are market-based rather than performance based in their
design. The commenters state that since these monitors are not considered instruments of commerce,
normal monitoring downtime provisions should apply.

Comment 2: Commenter 17877 notes that hours when a monitor is out of service should be counted as
monitor down time against the percent monitor availability, but substituting data is unnecessary.
According to the commenter, maintaining a consistent set of rules to govern monitors that are only used
to demonstrate compliance with an emission limit not tied to trading, simplifies the assurance of on-
going compliance for both the regulated community and the regulators. The commenter states that
eliminating missing data substitution for these monitors will also reduce the file size, complexity, and
time required to maintain and report quality assured data.

2.	Options for missing data substitution.

Comment 3: Commenter 17620 suggests that sources should be required to infer emissions during
monitor downtime at the highest daily rate over the past 90 days during each hour that a monitor is not
in service.

Comment 4: Commenter 17818 disagrees with the EPA's proposal to not require data substitution
during monitor downtime for Hg, HC1, or PM CEMS. The commenter understands that under the Acid
Rain Program the data substitution is essential to properly account for all mass emissions for the
pollutant in question, but for the proposed rule, compliance with HAP emissions limitations takes place
over a relatively long period of time. The commenter's opinion is that it is appropriate to require data
substitution for compliance with long-term emission rate limits to help ensure that a more accurate
indication of unit emissions is developed during all periods of unit operation in order to assess the unit's
compliance with the applicable emissions limitation. The commenter also notes that a requirement for
data substitution will also help encourage the owner/operator to maintain the related CEMS in a high
state of accuracy and availability.

Comment 5: Several commenters (17316, 17821, 17881) state that there are conditions other than those
listed in section 63.10020(b) that are legitimate reasons for monitoring system data loss and should also
be excluded from downtime reporting. The commenters state that these conditions include: planned and
unplanned preventive maintenance, corrective action maintenance, diagnostic checks, linearity tests,
system integrity checks, cylinder gas audits, QA/QC, system purges, installation of system upgrades,
etc. The commenters request that the EPA revise section 63.10020 to reflect that these conditions are not
deviations of monitoring requirements.

Comment 6: Commenter 17316 states that traditionally CEMS regulations have been performance
based, and this approach has worked well. The commenter states that if the EPA believes monitoring
system data loss to be a significant issue then the rule might establish a minimum data recovery

219


-------
threshold, such as 95 percent data availability per quarter, exclusive of calibrations, preventive
maintenance and QA testing, as is done in many permits.

Comment 7: Commenter 18023 states that a penalty should not be associated with Hg system
availability or monitor downtime. The commenter states that this is because: (1) Hg monitor repairs take
much longer to recover and settle once the system is returned to service than current CEMS analyzers
for NOx and SO2, (2) QA/QC activities take longer to perform, especially with the required calibrator
checks, and (3) the sorbent trap versus continuous monitor issue is almost an apples to oranges argument
regarding availability with missing days/weeks for sorbent traps versus missing hours for monitors.
According to the commenter, section 6.1.3 will only increase the amount of monitor downtime; total
availability should be calculated and recorded for tracking purposes but penalties should not be
associated with them, especially with the limited experience performing QA/QC with these devices.

Comment 8: Commenter 18023 states that under section 6.1.3 Data Reduction and Calculations, the
rule should allow the use of valid Part 75 substituted data for these parameters since those substituted
values are acceptable to the EPA for other emission monitoring programs.

Comment 9: Commenter 17886 states that section 63.10020(c), should exclude preventative
maintenance and corrective action maintenance activities in what should be considered a deviation of the
monitoring requirement.

Response to Comments 1-9: We have not included any specific minimum data availability
requirement for CEMS or other monitoring in this final rule nor do we provide a specific tool for data
substitution. We believe that there are other provisions in the final rule to provide incentives to conduct
monitoring in a manner consistent with good air pollution control practices and to provide data sufficient
to demonstrate compliance with a relatively long-term emissions rate limit (e.g., lb/MMBtu or lb/MWh).
We agree that data quality certainty associated with any calculated value decreases with the collection of
fewer data such as would occur with extended periods of monitoring system downtime. Even so, we
believe also that it is necessary and critical to compliance with the regulation that a source uses all
measured data collected during an averaging period to assess compliance regardless of any periods of
missing data. Sources should not disqualify any data otherwise meeting required data quality
requirements simply because there were data missing for other hours or days of the averaging period.

Instead of a minimum data availability threshold that would invalidate data collected for some averaging
periods because one did not collect data for at least "x" percent of an averaging time, the final rule
requires that a source report as deviations to the rule failure to collect data during required periods and
that are not covered by exceptions allowed in the final rule.

On the issue of applying a data substitution procedure to represent actual emissions or pollution control
performance, we believe that defensibility concerns make it incumbent on you to collect and evaluate
other information in accordance with 40 CFR section 63.6(f)(3) during periods of monitoring downtime
to assure compliance with the applicable emissions limitations and standards.

We believe that enforcement authorities also can and should determine whether a source is meeting any
monitoring system operating requirements. Should the source or the enforcement authority be concerned
about the representativeness of data such as during periods of missing data, either may consider
collecting information through other means (e.g., supplemental emissions testing) to fill data gaps not
only because such gaps are deviations from the rule but such gaps can lead to uncertainty about
compliance status.

220


-------
We further believe that the final rule provides sufficient means to ensure CMS performance and ongoing
compliance without specifying an arbitrary numerical minimum data availability or data substitution
requirement. We believe that specifying that failure to collect required or otherwise excepted data is a
deviation from the rule will provide the necessary incentive to collect data sufficient to demonstrate
compliance with the limits in the final rule.

221


-------
5A13 - Testing/Monitoring: Oil monitoring option
Commenters: 17316, 17870

Comment 1: Commenter 17316 observes that section 63.10011 seems to indicate that a unit may not
fire any fuel whose Hg, chlorine, fluorine or non-Hg total Metals content is greater than that measured in
the fuel combusted during performance testing (unless the unit is equipped with a CEMS), so that HAP
content of the fuel combusted during performance testing establishes an upper bound on the HAP fuel
content for all subsequent fuel deliveries (until the next performance test), without any consideration of
the extent to which performance test emissions were below the applicable MACT standard. The
commenter states that this approach to setting fuel based MACT operating limits seems unnecessarily
restrictive, and imposes very difficult compliance issues, as the HAP content of fuel oil is not subject to
contract specification. The commenter proposes an alternative method to establish a maximum allowed
HAP: adjust the HAP content of the fuel oil combusted during performance testing to account for the
amount by which measured stack HAP emissions fell below the applicable HAP standard. The
commenter states that this same approach could be applied to all fuel oil HAP constituents because: (a)
the only source of Hg, chlorine, fluorine, and non-Hg metals is the fuel itself, and (b) because it is
reasonable to assume that the fraction of HAP in the fuel emitted as stack emissions should be relatively
constant, so long as any add-on controls are operating properly, it would seem reasonable and
appropriate to proportion up the HAP content of the fuel combusted during performance testing, by the
ratio of HAP emission standard to the measured HAP emissions, in order to determine an appropriate
operating limits for each HAP constituent in fuel oil. According to the commenter, this approach
protects the standard, but avoids placing an unmanageable and unfair compliance (fuel) restriction on
the site.

Response to Comment 1: The comment is moot because the rule no longer requires fuel analysis or
operating limits based on non-Hg metals content of fuel. The only fuel monitoring provision in the final
rule is an option for liquid fuel units to use fuel moisture monitoring. If you combust liquid fuels and
you wish to demonstrate ongoing compliance with HC1 and HF emissions limits by measuring fuel
moisture content of fuel in place of quarterly stack testing.

Comment 2: Commenter 17316 states that in regard to requirements that if a source demonstrates
compliance with HAP limits "based on fuel analysis, you must conduct monthly fuel analysis for each
type of fuel burned." The commenter notes that oil is a homogeneous fuel that is relatively consistent
(from shipment to shipment), and therefore such frequent fuel sampling and analysis for oil-fired EGUs
is not warranted.

Comment 3: Commenter 17316 states that the monthly fuel analysis required in section 63.10006(s)
contradicts the discussion of this topic in the preamble (FR page 25053 columnl) which specifies that
(after the initial compliance demonstration by fuel analysis)], the EPA "is proposing a source be
required to recalculate the fuel pollutant content only if it burns a new fuel type or fuel mixture." The
commenter is concerned that this requirement is unjustified for sites that receive oil deliveries less
frequently than monthly. The commenter proposes that fuel sampling for oil fired units only need be
conducted in months that additions are made to the oil storage tank serving the boiler, but this sampling
should be conducted subsequent to all deliveries in the month.

222


-------
Response to Comments 2-3: Much of these comments are moot because the rule no longer requires
fuel sampling; however, the agency agrees that fuel moisture sampling (if that option is selected by a
source) need only occur on delivery of a new shipment of fuel oil.

Comment 4: Commenter 17870 asks for clarification of the rule allowing fuel analyses to demonstrate
initial and continuous compliance with applicable emission limitations, as an alternative to performance
stack testing and continuous compliance. The commenter states that in the rule, owners/ operators of all
affected liquid oil-fired units may perform fuel analyses to demonstrate initial and continuous
compliance, but in the preamble (FR page 25031) limited-use liquid oil combustion units are allowed "to
demonstrate compliance with the Hg emission limit, the HAP metals, or the HC1 and HF emissions
limits separately or in combination based on fuel analysis rather than performance stack testing, upon
request by you and approval by the Administrator." The commenter asks for clarification on whether
this applies to limited-use or all liquid oil-fired units.

Response to Comment 4: In large part, this comment is moot, as the rule no longer allows metals or
hydrogen halide sampling of fuel oil. As mentioned elsewhere, in reviewing comments on monitoring
frequency and burden, the agency dropped fuel analyses and operating limits based on those fuel
analyses, reduced stack testing frequency to quarterly for both units with and without controls, and
developed a stack testing exemption in quarters with limited operating hours. In particular, units that
exhibit limited use - less than seven days of boiler operation per quarter - are exempt from testing for
that quarter; however, each unit must perform a stack test at least annually. The limited use provision
gives relief to sources while maintaining expected emissions performance. In addition, if an EGU has an
oil-fired capacity factor of less than 8 percent evaluated on a 24 month block average, then the only
standard that applies is the performance tune-up requirement (see Comment Code 4D02 of this
document). Should an owner or operator of a liquid oil-fired unit choose not to conduct stack testing to
demonstrate compliance, the rule allows an owner or operator to choose continuous monitoring as an
alternative means of demonstrating compliance. In addition, the rule will still contain HC1 and HF
emissions limits for units that combust fuel oil and use of emissions testing or of CEMS to demonstrate
compliance with those emissions limits, but the rule will allow moisture content sampling of the fuel oil
as an alternative means of demonstrating compliance for units that have fuel moisture content no greater
than 1.0 percent. The rule no longer requires establishment of operating parameters for control devices
for these pollutants. See more discussion of the EPA's responses to operating parameter monitoring
under Comment Code 5A06 in this document.

223


-------
5A14 - Testing/Monitoring: Other

Commenters: 16513, 16849, 17316, 17402, 17620, 17622, 17626, 17627, 17637, 17638, 17655, 17681,
17690, 17696, 17697, 17704, 17705, 17715, 17716, 17718, 17724, 17725, 17729, 17730, 17731, 17737,
17739, 17740, 17754, 17758, 17760, 17761, 17767, 17775, 17781, 17796, 17800, 17803, 17804, 17805,
17807, 17808, 17812, 17813, 17816, 17818, 17820, 17821, 17838, 17855, 17856, 17867, 17868, 17870,
17873, 17880, 17881, 17886, 17902, 17909, 17925, 17927, 17928, 18014, 18024, 18025, 18031, 18034,
18039, 18428, 18444, 18477, 18487, 18498, 18502, 18539, 18963, 19033, 19114, 19120, 19121,
19536/19537/19538, 18023

1. Commenters concerned about the proposed frequency of performance tests.

Comment 1: Numerous commenters (17402, 17627, 17638, 17681, 17696, 17704, 17716, 17718,
17725, 17737, 17740, 17758, 17760, 17775, 17796, 17800, 17803, 17804, 17807, 17816, 17820, 17821,
17838, 17856, 17867, 17870, 17881, 17902, 17909, 17925, 18014, 18025, 18031, 18428, 18444, 18477,
18963, 19033, 19114, 19120) believe that the proposed frequency of performance testing under section
63.10006 is excessive or overly burdensome.

Comment 2: Commenters 16513 andl7804 state that the rule would significantly increase the workload
of state agencies by as much as 50 percent as a result of observing emission tests and/or reviewing
emission test protocols, and updating AFS. Commenters recommend revising the testing to quarterly or
biannually. .

Comment 3: Several commenters (17402, 17627, 17704, 17716, 17718, 17760) state that the EPA
should allow facilities to comply with the performance testing requirements on an annual basis similar to
their current permit requirements. Commenter 17402 believes that less frequent stack testing coupled
with more frequent fuel sampling can ensure continuous compliance because data in the docket indicate
that over the long term, emissions are fairly consistent despite potential variability in fuels and
operations. Commenter 17402 believes that annual Method 29 stack testing combined with existing
permit requirements (to properly operate air pollution control equipment at all times) combined with
monthly fuel samples and calculations (consistent with proposed section 63.10011) compose a viable
means for ensuring continuous compliance. Commenters (17402, 17718) believe this suggested
combination is preferable to the logistical and cost concerns implicit in monthly or bi-monthly testing
requirements, and the commenters cite the limited availability of test crews, coordination with system
dispatch, scheduled boiler maintenance, and winter storms as constraints that make the proposed
monthly and bi-monthly testing frequencies infeasible. Commenter 17402 provides an analysis of stack
test data submitted by EGU operators under the ICR to support his position that emission rates are
stable.

Comment 4: Commenter17760 indicates that many dual-fuel (oil or gas) units maintain permits to burn
fuel oil for periods of high electricity demand when natural gas may not be available (due to residential
heating demand) and states that recent natural gas prices make fuel is concerned that the monthly or bi-
monthly testing requirements will force dual. The commenter states that first, the proposed frequency of
testing will impose a significant cost burden on plant operators. For example, all of commenter 17803's
units are gas capable and, with the current difference in oil and gas prices, oil is consumed only during
periods of gas unavailability or as required by the New York Independent System Operator to ensure
reliability during periods of high electric demand. According to the commenter, monthly testing would
result in significant economic burdens. For example, commenter 17803's cost of the uneconomic oil
consumed during the 2010 ICR testing last year was approximately $2-3 million. Second, states the

224


-------
commenter, inflexible testing schedules may induce units to run solely for testing purposes, leading to
increased emissions. According to the commenter, any oil-fired units are operated as peakers or cycling
units, and may spend a significant portion of the year off-line and the proposed testing requirements
would require these units to run even if there were no demand for additional power. Commenter 17316
adds that for dual fuel (oil/gas) units, the proposed testing regimen is even more environmentally
counter- productive because these units tend to operate on natural gas during the ozone season, but
proposed section 63.10007(c) would require the firing of oil during ozone season.

Comment 5: Several commenters (17316, 17627, 17716, 17718, 17725, 17760) state that the proposed
performance testing requirements for sources without CEMS are cumbersome and expensive for units
with low annual capacity factors (e.g., oil-fired units) because frequent performance testing could
require operation of such units during periods of low electricity demand when such units normally do
not operate. Commenters (17316, 17760) state that in some cases the proposed testing frequency for oil-
fired units with low annual capacity factors will result in an increase in annual HAP emissions that could
exceed any reduction in hourly emission rates achieved by the rule. Commenter 17760 adds that if the
EPA does not agree with annual testing of oil-fired units with low annual capacity factors, then the
testing frequency should be a function of "fuel operating" hours.

Comment 6: Several commenters (17627, 17718, 19114) believe that the EPA's assertion that most
units will choose to install CEMS rather than the burdensome stack testing option may be faulty because
HC1 CEMS technology is not yet available, PM CEMS are still quite unproven, and other CEMS
systems may be incapable of measuring emissions as low as the EPA has proposed. Commenter 19114
further states that for low capacity units they have determined that they could not complete such testing
at all of its units within a 2-month period due to lack of test crews, unit scheduling, scheduled
maintenance, and other considerations. According to the commenter, the EPA should consider the
frequency and types of monitoring appropriate for various subcategories, including an exemption for
low capacity factor and LEE units.

Comment 7: Several commenters (17638, 17681, 17725, 17740, 17758) state that the proposed monthly
or bi-monthly testing frequency is excessive, unnecessary, and cost prohibitive. Commenters (17638,
17681, 17758) note that the EPA established the limits based on single tests from multiple units, and
conclude that there is no basis for the proposed frequency.

Comment 8: Commenter 18477 states that to conduct source testing, commenter must establish a
schedule that maximizes the amount of work done by the vendor in the minimal amount of time, in order
to manage the exorbitant cost of importing such expertise and equipment. The commenter states that any
upset that occurs during the source testing schedule, a common phenomenon when testing multiple units
within a relatively short time frame, further strains commenter's generation resources. Commenter states
the current proposed rule, assuming installation of control devices for non-Hg metals on all 14 of
commenter's units, testing each of 14 steam units every other month equates to 84 source tests annually.
If the four units commenter has identified for potential retirement were not equipped with such devices,
108 source tests would be required under the proposed rule. In either case, states the commenter, the
proposed rule's non-Hg metals source testing regime would be a severe burden to our already
overburdened ratepayers. The commenter notes that the cost of source testing in significantly higher
than in the continental U.S. and that the commenter paid a 20 percent premium to perform the ICR
testing.

225


-------
Comment 9: Several commenters (17760, 17881, 18477) note that annual testing would be consistent
with the industrial boiler MACT (DDDDD), stationary combustion turbine MACT (YYYY), and the
RICE MACT (ZZZZ) that provides semi-annual to annual testing.

Comment 10: Commenters 17870 and 17881 state that the proposed testing frequency is impractical to
conduct especially in the northern climates where temperatures in many months (about 5) of the year are
too cold. According to the commenters, severe weather events can postpone stack access for safety
reasons (ice, lightening), thus reducing the margin of maintaining such a rigorous test schedule. The
commenters state that the process of submitting test notifications, conducting the test, and then reporting
is a never ending paperwork loop. Commenter 17881 suggests that annual testing is more reasonable for
units without CEMS but with controls and operating limits and semi-annually for units with
CEMS. Commenter 17870 suggests the all stack testing requirements governing coal-fired EGUs should
be no more frequently than quarterly under standard operation (i.e., unless boiler operations or
characteristics are substantially altered, in which case initial testing should be repeated). According to
the commenter, quarterly stack testing in combination with parameter monitoring (discussed below)
should be enough to ensure that a unit is operating within the required limits, and quarterly testing would
capture seasonal variations in operation while not unnecessarily repeating testing of the same conditions.

Comment 11: Commenter 18502 recommends that the EPA reduce the compliance testing requirements
based on the relatively small size and emissions and remoteness of non-continental EGUs burning liquid
oil.

Response to Comments 1 -11: In response to these comments, the final rule includes a number of
changes from the proposed rule that will reduce the overall testing required under the final rule. First,
the final rule establishes a separate subcategory for an EGU with an annual oil-fired capacity factor of
less than 8 percent. These units are subject only to the performance tune-up work practice standard in
the final rule. Second, the optional periodic testing requirements have been made consistent between
controlled and uncontrolled sources, with a reduced frequency of quarterly performance testing. In
addition, the final rule has removed all requirements for duplicative testing of a HAP and surrogate
standard (such as filterable PM and HAP metals).

Comment 12: Commenter 17856 questions the need for such frequent stack testing for units with
CEMS because of the extensive operational and parametric monitoring.

Response to Comment 12: The final rule has been amended to not require additional performance
testing if complying with Hg, HC1 or S02 CEMs. For sources electing to use PM CPMS, the
performance testing frequency has been reduced to annual testing.

Comment 13: Multiple commenters (17638, 17681, 17690, 17716, 17725, 155, 156, 17758, 17760,
17803, 17820, 17870, 17902, 17909, 18014, 18025, 18428, 18498) believe that the testing frequency for
units opting to comply with the non-Hg HAP metal or HC1 emission limits should be once every four
unit operating quarters (not calendar quarters), but no less frequently than once every eight calendar
quarters following the required frequency for RATA's at 40 CFRPart 75, Appendix B, section 2.3.1.1
and using the definition for "operating quarter" under part 72.2 (i.e., 168 or more unit operating hours).
Commenters 17820 and 17881 state that testing guidelines under section 63.10006(n) should use the
operating days and quarters approach of Part 75.

Response to Comment 13: As previously explained, the optional periodic testing requirements have
been made consistent between controlled and uncontrolled sources, with a reduced frequency of

226


-------
quarterly performance testing. In addition, the final rule has removed all requirements for duplicative
testing of a HAP and a separate alternate equivalent standard (such as filterable PM and HAP metals).

Comment 14: Multiple commenters (17716, 17725, 155, 17820, 18498, 17775, 17800) request that the
testing provisions in the final rule incorporate a grace period similar to the Part 75 provisions. According
to the commenters, such a grace period allows a source time to complete testing after coming back
online and would benefit sources and the EPA by eliminating the need for submission of source specific
petitions to seek minor extensions of testing deadlines.

Response to Comment 14: The final rule allows for testing grace periods consistent with those allowed
in part 75.

Comment 15: Several commenters (17716, 17821, 17881) state that the specific testing deadlines that
are provided in section 63.10006(n) will be overly burdensome not only for limited operation units, but
also for units in extended planned or unplanned maintenance outages. The commenters note that section
63.10006(n) does provide windows for testing, they may be inadequate for planned unit maintenance
outages. Commenter 17821 suggests establishing guidelines and allow sources to work with state and
local permitting agencies to schedule tests.

Comment 16: Commenter 18025 recommends that a unit operating hour be defined as a clock hour
during which a unit combusts any regulated fuel, either for part of the hour or for the entire hour.
Commenter is recommending that this definition apply specifically to the regulated fuels under the
Utility Toxics Rule (e.g., coal and liquid oil). By requiring a minimum level of operation to trigger stack
testing requirements, states the commenter, this approach would ensure that no unit is run simply for the
sake of testing

Response to Comments 15 -16: As previously explained, the optional periodic testing requirements
have been made consistent between controlled and uncontrolled sources, with a reduced frequency of
quarterly performance testing. In addition, the final rule has removed all requirements for duplicative
testing of a HAP and a surrogate standard (such as filterable PM and HAP metals).

Comment 17: Commenter 17681 recommends the testing schedule, instead of annual testing on a 13-
month timescale, be revised to "or every other federal fiscal year" or something along those lines so that
facilities may coordinate testing with their state required permits for consistency.

Comment 18: Commenter 19033 recommends that the HC1 sampling frequency be reduced from every
other month to quarterly in the second year, and biannual the third year if HC1 emissions are measured
to be non-detectable for all tests conducted. Accordingly, the commenter recommends that section
63.10006(j) be amended, as follows: (j) For solid oil-derived fuel- and coal-fired EGUs without HCI
CEMS but with HCI emissions control devices, you must conduct all applicable performance tests for
HCI emissions according to Table 5 and section 63.10007 at least every other month during the first
calendar year after the standard becomes applicable. Provided that HCI emissions are measured to be
non-detectable, the HCI emissions testing frequency may be reduced to quarterly during the second year
and bi-annual the third year.

Commenter 17722 states that for language in section 63.10006(j), the EPA should add an exception for
EGUs monitoring continuously by S02 CEMS, as the bi-monthly performance tests are not required for
continuously monitored surrogates.

227


-------
Comment 19: Commenter 17821 states the proposed testing frequency constrains a company's ability
to follow customer demand and increases a company's cost to operate its generation resources.
According to the commenter, existing tests such as periodic RATAs are less frequent, of shorter
duration, and/or allow much more operational flexibility, and the proposed Utility MACT tests by
comparison are far more frequent, of longer duration, and demand more operational restrictions
requiring operators to focus on making their generating units available for testing conditions to the
detriment of the primary function of generating electricity. The commenter states that the proposed rule
is too prescriptive in telling sources how they are to operate their facilities. According to the commenter
the EPA fails to recognize that requiring a single unit to satisfy testing conditions also constrains other
units in the system.

Comment 20: Commenter 17796 questions the proposed frequency of stack tests in section
63.10006(d). As an alternative to the requirement for monthly or bimonthly stack tests (depending on
the use of control devices), the commenter recommends that once the initial performance test is
conducted for PM (filterable and condensable) and non-HAP metals, and fuel sampling procedures and
operating parameters are established, compliance will be assured by the use of such fuel sampling and
operating data combined with less frequent (semiannual) stack testing.

Comment 21: Commenter 17925 recommends that continuous compliance source testing should be
required no more frequent than annually. The commenter states that the EPA has had a past history of
requiring annual source testing at coal-fired units where continuous monitors for certain emission
species either didn't exist or couldn't be applied at the source; for instance, at some coal fired units in
the past, opacity monitors couldn't be applied on wet plumes after scrubbers. As a result, states the
commenter, the EPA required annual total particulate testing by Method 5 in lieu of requiring the
operator to make an opacity monitor perform on the wet plume. The commenter requests the EPA to
apply the same sound judgment now with respect to frequency of source testing for demonstrating
continuous compliance with metals emissions and HC1.

Comment 22: Commenter 17316 suggests that performance testing for oil-fired units should be
conducted every 3 years rather than the schedule proposed in section 63.10006(f),(g),(l) and (m) because
the proposed schedule is unjustified and a very substantial economic burden for smaller utilities.
Commenters (17316, 17725, 17760) indicate that the total expenditures for such a test program include
the direct monthly costs of contracted testing services and the significant costs of operating oil-fired
units strictly for monthly tests when other more economical generating units are available to meet the
demand for electricity or requiring dual fired units to burn fuel oil for testing purposes when natural gas
prices are lower than residual fuel oil. According to commenter 17725, performance testing of a unit
without metals or acid gas controls requires a minimum of 4 full load hours per month; an additional 2
hours at full load for boiler stabilization; potential additional runs if the test crew has problems; and time
for calibrations between test runs. The commenter estimates such a unit would operate for 72 hours per
year just for testing, not including the time to start-up the unit, ramp the unit to full load and then ramp
down the unit. Commenter 17725 states that review of published data for 2008, 2009, and 2010 shows at
least 34 residual oil-fired units whose 3-year annual capacity factors are 5 percent or less.

Comment 23: Several commenters (17316, 17870, 18428) state that oil is a homogeneous and
reasonably consistent fuel, so that variations in the metals, chlorine, and fluorine contents should not be
significant and therefore monthly or bimonthly testing is not warranted. Commenter 17870 states that
fuel analysis on each shipment of oil should be sufficient to demonstrate compliance. Commenter 18428
states that in the preamble, the EPA states that additional performance tests for Hg are conducted "at
least annually." However, there is no reference to this annual testing in the proposed rule. Given the

228


-------
extremely low level of Hg in oil, states the commenter, any requirement or reference to annual testing
for Hg emissions from oil-fired units is unnecessary and should be removed

Comment 24: Commenterl7704 appreciates the proposal's inclusion of an alternative to the use of PM
CEMS for monitoring non-Hg metals emissions, but the commenter states that the bi-monthly stack
testing alternative is not practical because the effected source operator does not have resident stack
testing crews, and the scheduling of tests with contract testing crews and the scheduling of testing loads
with the grid reliability control center would be difficult to do every two months. Commenter 17704
states that the amount of metals in the PRB coal utilized at the effected source does not change
significantly and annual testing should be sufficient for monitoring the non-Hg metals.

Comment 25: Several commenters (17716, 17725, 17758, 18014) state that the proposed frequency of
performance testing is not consistent with the expected variability in emissions because units without
add-on control systems are required to complete stack test less frequently than units with add-on control
systems, but for units without add-on control systems, the emissions of HC1, HF, and non-Hg metals are
most closely tied to fuel characteristics. These commenters and commenter 17402 suggest that in lieu of
the proposed monthly or bi-monthly frequency, periodic fuel analyses should be used to determine if a
significant change has occurred since the annual performance test. Commenter 17402 provides
suggested revisions to proposed section 63.10006 and section 63.10021 outlining a methodology for
using monthly fuel analyses and performance tests conducted every 4 unit operating quarters; the
suggested methodology includes criteria for using monthly fuel samples to determine when higher
frequency stack testing is required. Commenters (17716, 17725) cite statements in the preamble to the
proposal indicating that for liquid oil-fired units, no correlation was found between non-Hg metallic
HAP emissions and PM emissions or the operation of PM control devices. These commenters conclude
that the emissions of HC1, HF, and non-Hg metals are most closely tied to fuel characteristics and that
periodic assessment of fuel characteristics should be used to determine whether additional emission
testing is needed. This commenter also believes that the source's expected removal efficiency should
also be taken into consideration to minimize unnecessary testing.

Comment 26: Commenter 17718 encourages the EPA to maximize the efficiency of monitoring and
reporting requirements and to avoid redundancy. This commenter states that the data gathering
requirements in the proposal are extremely difficult due to the lack of approved test methods, data
variability, and short deadlines for testing. The commenter suggests that the EPA should extend the
testing frequencies to at least a quarterly basis to allow more substantial analysis of gathered data and to
reduce potential burdens resulting from more frequent laboratory analyses and test report submittals.

Comment 27: Commenter 17737 states that a monthly testing frequency is unmanageable for units that
do not have SO2 control technology or HC1 CEMS, and the commenter states that proposal provide no
explanation for this unprecedented frequency. According to the commenter all plausible operating
scenarios that could utilize the compliance option for sources without SO2 controls require use of fuel
with very low chlorine content. In such cases, states the commenter, fuel analyses provide assurance of
compliance at a fraction of the cost. This commenter believes the final rule should allow operators to
maintain records of the type of fuel being burned and to perform monthly fuel analyses to demonstrate
that the fuel chlorine content is within acceptable limits.

Comment 28: Commenter 17718 is concerned that the monthly or bi-monthly performance testing
option may be incompatible with timely submission of test reports under proposed section 63.10006(t)
because historically, testing firms and labs have not handled the high volumes of work implicit in this
compliance option.

229


-------
Comment 29: Commenter 17821 states that the proposed initial testing schedule requiring tests within
30-operating days of the startup of new controls is too tight. According to the commenter, few
installation projects will meet their construction deadlines and will force initial testing into very
compressed schedules.

Comment 30: Commenter 17807 states that the proposed testing frequency is not practicable and not
justified. The commenter suggests annual stack testing and a CAM plan instead of bimonthly testing.

Comment 31: Commenter 17880 supports the requiring of liquid oil-fired units to conduct additional
performance testing for Hg on an annual basis; conduct additional performance tests for HAP metals and
acid gasses every 2 months for units that have emissions controls, and monthly for units that do not.

Comment 32: Commenter 17867 notes that several MACTs allow for less frequent testing given
consecutive passing results as follows:

•	40 CFR 63 subpart DDDD (Boiler MACT) section 63.7515 - testing frequency is annual until
compliance is demonstrated for 3 consecutive years, then frequency is relaxed to every 3 years.

•	40 CFR 60 subpart KKKK (Combustion Turbine NSPS) section 60.4340 - testing frequency is
annual unless emission are less than 75 percent of the standard, then frequency is relaxed to
every 2 years.

•	40 CFR 60 subpart DDDD (CISWI MACT) section 60.2720 - testing frequency is annual unless
emissions are less than the standard or 75 percent less than the standard (depending on the
pollutant), then frequency is relaxed to every 3 years.

•	40 CFR 60 subpart CCCC (CISWI MACT) section 60.2155 - testing frequency is annual unless
emissions are less than the standard or 75 percent less than the standard (depending on the
pollutant), then frequency is relaxed to every 3 years

According to the commenter, metals and HCI stack testing every other month is unnecessarily
burdensome. Commenter suggests the frequency should be extended to every 6 months if two
consecutive tests demonstrate compliance with the standard. The commenter states that if two
consecutive semi-annual tests demonstrate compliance, frequency should be extended to annual testing,
and frequency should be increased if a subsequent performance test indicates the emission standard is
not being met or if more than 50 percent of the fuel has been switched to a different type of coal (e.g.,
subbituminous/bituminous, supply from different basin).

Comment 33: Several commenters (17681, 17870, 18034, 18428) question whether, because of the
prescriptive testing deadlines, if a unit is not operated within the timeframes specified will the unit be
required to start-up simply for testing purposes.

Response to Comments 17 - 33: See response to Comments 15 and 16.

Comment 34: Commenters (17800, 17886) state the start date of the performance tests under section
63.10005 should be flexible to allow for monitor certification to be completed, operating conditions to
be established, and shakedown of control devices to be performed.

Response to Comment 34: The Agency finds that the rule's start dates of the performance tests are
flexible and will allow for monitor certification and similar activities to occur.

230


-------
General Response to Comments 1 - 34: For stack test frequency, the EPA has modified the final rule
to require quarterly testing if used to demonstrate continuous compliance and included an exemption for
testing in quarters with low utilization (<168 operating hours). In addition, EPA agrees that testing
should be required only for the emission limit that the source is complying with, and thus the final rule
does not require testing of both the HAP and a separate surrogate standard (such as filterable PM for
HAP metals).

2. HC1 testing section 63.10006(j).

Comment 35: Commenter 17821 requests that the EPA clarify this section of the rule to indicate
whether sources choosing to use the alternate method of compliance with the HC1 limitations defined in
Table 5 (use of a CEMS to measure SO2 emissions and limiting the emissions rate to less than 0.2
lb/MMBTU) are required to conduct HC1 performance testing every 2 months. With section
63.10000(c)(1) defining a SO2 CEMS as an alternative to an HC1 CEMS, the commenter recommends
that the EPA should not require sources using this alternative to conduct performance testing for HC1
every 2 months. Rather, the commenter recommends that the frequency of performance testing for HC1,
when utilizing the alternative method of compliance with a sS02 monitor and a reduced S02 emission
rate, should be the same as for those sources choosing to utilize an HC1 CEMS.

Response to Comment 35: The final rule has removed all requirements for duplicative testing of a HAP
and a surrogate standard (such as HC1 and S02). Facilities complying with a surrogate standard do not
have to perform periodic testing for the corresponding HAP.

Comment 36: Commenter 17696 states that for coal-fired EGUs without an HC1 emission control
device, the key factor in determining maximum potential HC1 emissions is the maximum coal chlorine
input. For coal-fired EGUs with HC1 control devices, states the commenter, a second key factor in
determining maximum potential HC1 emissions is the control device's operating parameters, which
under the proposed rule also must be continuously monitored to assure compliance, and as long as there
is no change in coal type or coal mixture (or change in emission control device operations), there is no
need to perform HC1 stack testing every month or every other month - simply keeping the coal chlorine
input below maximum allowable levels (and, as applicable, keeping the control device's operating
parameters within allowed ranges) is sufficient to ensure continuous compliance.

Response to Comment 36: The final rule has removed most of the options for fuel sampling and
analysis as a compliance option. Sources choosing to not use HC1 CEMS for uncontrolled sources must
perform periodic performance testing. However, if you combust liquid fuels and you wish to
demonstrate ongoing compliance with HC1 and HF emissions limits by measuring fuel moisture content
of each shipment of fuel in place of quarterly stack testing, you may develop a unit-specific approach
utilizing fuel moisture content measurements, collect data necessary to support your approach, and
petition the Administrator under 40 CFR section 63.7(f) for an alternative compliance testing approach.

Comment 37: Commenter 17725 requests that the final rule clarify that testing for HC1 is not required if
the site operator has instituted the alternate compliance method of percent water in fuel deliveries.

Response to Comment 37: The final rule has removed most of the options for fuel sampling and
analysis as a compliance option. However, if you combust liquid fuels and you wish to demonstrate
ongoing compliance with HC1 and HF emissions limits by measuring fuel moisture content of each
shipment of fuel in place of quarterly stack testing, you may develop a unit-specific approach utilizing

231


-------
fuel moisture content measurements, collect data necessary to support your approach, and petition the
Administrator under 40 CFR section 63.7(f) for an alternative compliance testing approach.

3. Reduced frequency criteria.

Comment 38: Commenter 17821 states that the reduced stack test provisions at section 63.10006(c) are
too burdensome. Commenter believes that the threshold for extended testing frequency should be that
the unit demonstrates 80% - 90% of the standard because the EPA is also requiring worst-case fuel
conditions, full load, and other requirements intended to provide the absolute worst case test conditions
for what are relatively short-term periods. In the real operating world, states the commenter, a unit will
simply not continue to operate in worst-case conditions, rather, the average fuel concentration will be
less, load will decrease, etc.

Comment 39: Commenter 17821 asserts that the requirement that a source must demonstrate
compliance for 3 years is far too burdensome. The commenter notes that the EPA states "If a
performance test shows emissions in excess of 50 percent of the emission limit, you must conduct
performance tests at the appropriate frequency given in section (c) through (m) of this paragraph for that
pollutant until all performance tests over a consecutive 3-year period show compliance"; in other words
for the parameters where the EPA is requiring sources to test every month, or every other month,
sources will have to conduct 18-36 individual test before they can qualify for reduced frequency.
According to the commenter, this imposes a burden on the source and the permitting agency and it
appears the EPA is attempting to ratchet the emission limit down by half.

The commenter recommends that the EPA make two important changes in the frequency of its required
reference method testing: first, the EPA should require reference method testing that is no more often
than quarterly for any pollutant and equipment configuration, and second, once a unit has successfully
demonstrated emission levels that are at no more than 80% to 90% of an applicable standard for 2
consecutive quarters, the testing frequency be reduced to semi-annually. The commenter states that then
once a source has demonstrated compliance with the applicable standard for two additional tests, the
frequency would be further reduced to annually. Finally, states the commenter, the EPA must address
the issue of how a limit of detection is handled in the context of reduced testing frequency.

Response to Comments 38-39: The final rule has been amended to quarterly testing for all pollutant
and equipment configurations. The EPA disagrees with the 80 to 90% criteria for reduced testing
suggestion due to the option for use of CEMS instead of periodic testing and the removal of prescriptive
parameter and fuel monitoring.

Comment 40: Commenters 1775 and 17800 state that the EPA should remove the 50% criterion for
reduced testing as the EPA provided no reason for this restriction. According to the commenters, the
EPA has not provided any data suggesting that any source could achieve 50% of the proposed limits
some of which are at or near the detection limits.

Response to Comment 40: The EPA disagrees with the commenter and will retain the 50%
criteria. The emission standards in the final rule are at least three times the RDL, so any source below a
typical detection limit would meet these criteria. In addition, the quarterly periodic performance testing
is an option for sources choosing to not install CEMS or PM CPMS.

Comment 41: Commenters 17881 and 19033 state that section 63.10006(q) is unclear. According to the
commenters, it seems the intent is to require that the more frequent testing frequencies must be met if a

232


-------
performance test shows emissions greater than 50% of an allowable limit, yet the increased testing
frequency is required until all performance tests over a consecutive 3-year period show compliance.

Response to Comment 41: The reduced frequency option is only available to sources that meet the 50%
criteria during the 3 years of periodic testing.

Comment 42: Commenter 17881 states that section 63.10006(o) allows for reduced frequency of testing
from annual or more frequent to once every 3 years (i.e., no more than 37 months) after the previous
performance test. The commenter states that in order to qualify for this reduced testing frequency, 3
consecutive years of testing must show that emissions are at or below 50% of the applicable emission
limit. In light of the very stringent emission limits, the commenter questions why results have to be less
than 50% of threshold. For comparison, states the commenter, in the Boiler MACT, to qualify for
reduced frequency, units had to demonstrate emissions at or below 75% of the emission limit. Also,
states the commenter, it seems disproportional for units that are testing bi-monthly or monthly to have to
conduct 18-36 tests to establish a pattern of compliance versus units testing annually to conduct as little
as three discrete tests. According to the commenter, reduced frequency should be based on the number
of passing consecutive tests; the RICE MACT utilizes this concept in that after compliance is
demonstrated for two consecutive semi-annual tests, the testing frequency can be reduced to annually.
The commenter suggests that for non-CEMS units there should be a tiered approach in regards to the
number of passing tests based upon the original testing frequency; i.e., six passing tests for bi-monthly
tests and 12 passing tests for monthly tests.

Response to Comment 42: In response to comments, the final rule has been amended to reduce the
frequency of testing from 1 or 2 months to quarterly testing. Also, the quarterly periodic performance
testing is an option for sources not choosing to install and operate CEMS.

Comment 43: Several commenters (19536, 19537, 19538) assert that the frequency of testing should
depend upon the variability of each parameter. According to the commenter, when a parameter is
variable, more frequent monitoring is required to assure continuous compliance; as a rule, where a
parameter fluctuates significantly over a period of time shorter than the specified monitoring interval,
the monitoring cannot assure continuous compliance. According to the commenter the proposed limits
are heavily premised upon the claim that the regulated emissions are very highly variable and the EPA
uses this justification in establishing extraordinarily aggressive statistical adjustments. The commenter
states that the EPA's calculations predict emissions from existing sources which range from 2 to 56
times greater than the average data yielded from a test. For new sources, states the commenter, the
EPA's calculations predict emissions from 2 to 6 times greater than the average, and according to the
EPA's beyond-the-floor analysis (or lack thereof) there are no operational methods available to reduce
that variability. Given the unavoidable variation, states the commenter, continuous compliance cannot
be determined using the periodic testing proposed in the rule. According to the commenter, if emissions
vary by a factor of 2 to 50 (or more), and there is no method available to reduce that variability, direct
measurement of emissions every month (or every other month) with annual to every 5 year re-tests, will
not ensure continuous compliance between those tests.

Response to Comment 43: We believe that frequency of testing be tied to source performance and be
reduced based on demonstration of continued lower emissions, not on potential emissions variability.
The EPA believes the provisions of the LEE exemption provide adequate a level of assurance with
compliance for better performing units. For non Hg HAP, the sources must show levels below the
threshold for quarterly performance tests over a 3-year period. In addition, any change to the process
that would result in an increase in HAP emissions would necessitate another performance test. These

233


-------
sources will also be subject to other rules containing provisions for parameter monitoring as discussed in
section 5A05.

Comment 44: Commenter 17718 requests that the final rule include a clarification to the proposed
language at section 63.10006(o) regarding the criteria for reducing the frequency of performance testing;
the final rule should clarify what constitutes "no change" and what information would be needed to
successfully pass these criteria. For example, states the commenter, it is unclear whether the "no
change" provision applies to the affected unit and is not inclusive of the entire facility.

Response to Comment 44: "No change" would apply to the affected unit.

4. Comments related to "highest content" of HAP.

Comment 45: Commenters 17731 and 17881 state that the requirement to use worst case coal with the
"highest content" of HAP in performance testing is not reasonably possible in part due to natural
variability. According to the commenters, there is a very real possibility that even if the worst case coal
could be identified, that coal very well may not be available for purchase. The commenters state that the
proposed rule also fails to distinguish emissions testing requirements among regulated parameters.
According to the commenters, the worst case coal is not likely to be the same relative to each of the
regulated parameters under the proposed rules. Thus, according to the commenters, EGUs would have a
nigh-impossible task of identifying a suite of worst case coals and procuring each of those in order to
conduct the required testing. Commenter 17881 suggests defining a primary fuel and retesting on
changes to the primary fuel. According to the commenter this approach was used in the CAMR rule
under section 75.81(d)(4)(iv). Commenter further notes that even if an EGU is diligent in trying to
determine the maximum HAP input levels based upon expected fuel(s), it is entirely possible that the
actual HAP input will increase beyond the levels observed during the initial performance tests/fuel
sampling and analysis simply due to fuel variability alone (and not a change in fuel type(s) or blends).

Comment 46: Commenter 17718 states that the proposed regulatory language (40 CFR 63.10007(c))
provides that performance tests must be conducted "while burning the type of fuel or mixture of fuels
that has the highest content..The commenter believes the EPA should clarify whether reference to
"type of fuel" simply means that if bituminous coal is typically burned then bituminous coal is to be
used during the test. According to the commenter, this section does not appear to require a determination
that the highest chlorine (or other constituent) content bituminous coal be used during the test. The
commenter also suggests clarification that "special fuels" are not required or expected for the
performance test.

Comment 47: Commenter 17781 states that for performance testing under section 63.10007(c) the EPA
should specify that fluorine content is only relevant for liquid oil-fired EGUs, as no other category of
EGUs are subject to HF emission limits.

Comment 48: Commenter 19121 states that placing testing criteria on multiple fuels is burdensome, and
close to impossible to include all fuel sources and blends within any single performance test.
Additionally, the commenter utilizes bituminous and subbituminous fuel from multiple sources and fire
as a blend. Fuel supply can be seasonal and based upon pricing, availability and access.

Response to Comments 45-48: Periodic performance tests must be conducted using the fuel type or
blending that would represent the highest HAP loading to the control devices for that period of testing. If

234


-------
the source is unsure which fuel would result in the highest HAP loading, they may perform multiple
tests within that test period or opt to use CEMS to ensure continuous compliance with the standard.

5.	Testing deadlines.

Comment 49: Commenters 17725 and 18498 state that testing deadlines should be established based on
time of the last test with no concern for the minimum amount of time since the last test. The commenters
state that there is no value to establishing a minimum amount of time before conducting subsequent
tests, and if a source completes the test before the applicable deadline, the future test schedule is simply
adjusted based on the completion date of the test.

Response to Comment 49: The final rule will be amended in order to remove the minimum amount
time since the last test requirement.

6.	Comments regarding performance testing and maximum operating load.

Comment 50: Commenters 17730 and 17886 state that the proposed rule requires that sources conduct
performance testing under the maximum normal operating load conditions when combustion is most
efficient and emissions will be at their lowest. The commenters state that for EGUs using CEMS the
performance test will run for 30 operating days. According to the commenters, it may not be possible for
sources to maintain a "maximum" normal operating load for a full 30 operating days. The commenters
believe that the EPA should simply require representative operation of the unit during performance
testing.

Comment 51: Commenter 17316 states that section 63.10007 indicates that performance testing must be
conducted at "maximum normal operating load"; however this term is not defined. Commenter suggests
that the rule allow sources to apply the Part 75 Appendix A, section 6.5.2.1 procedure to define three
operating load ranges for a unit (low, mid, high), and allow a source to perform testing at any load
within the "high" load range. According to the commenter, such an approach allows a source to test at a
representative load, but ensures testing is conducted at a high load, and hopefully such an approach
would reduce the need to perform multiple stack tests, while still basically satisfying the goal of
conducting measurements under worst case conditions. The commenter notes that the preamble to the
proposed rule indicates that load has little significant impact on HAP emissions (FR Page 25037).

Comment 52: Commenter 17881 states that specifying that the performance tests be conducted at
maximum routine operating load is not appropriate, as the EGU should have the flexibility of conducting
the test at whatever load is desired with the understanding that in those cases where compliance is
demonstrated through performance testing, the average load observed during the performance tests will
be used to set a maximum load restriction for all future operation (at 110 percent of the average load
during the tests).

Comment 53: Commenter 18024 recommends that if compliance can be achieved by co-firing natural
gas and oil at the same time, then a liquid fuel-only compliance demonstration would not be necessary
or appropriate so long as enforceable co-firing operating restrictions were implemented. Commenter
states that low load operation should be allowed as compliant operation if the mass emission rate of any
HAP is maintained below the equivalent full load HAP emission level calculated as the MACT Floor.
The commenter requests that the EPA develop a compliance option that represents normal operation of a
facility and eliminate testing in modes of operation that are rarely or never utilized.

235


-------
Comment 54: Commenter 18444 states that the EPA should require that states set maximum allowable
hourly heat inputs for each unit and that testing to determine compliance be conducted at these
maximum rates. According to the commenter, this heat input limit is especially important for pollutants
which do not have a continuous monitor and are tested infrequently (such as particulate HAP). The
commenter notes that the proposed rule language on maintaining heat input within 10 percent of the heat
input when compliance testing was done is too much leeway; especially with an ESP. The commenter
states that emissions can be about 50 percent higher with a 10 percent fuel gas flow rate increase through
an ESP. According to the commenter, air pollution control systems are designed for a maximum flue gas
flow rate which is directly related to heat input; ESPs are very sensitive to higher amounts of fuel being
burned, and scrubbers are also affected as well. The commenter recommends testing within 5 percent of
the maximum allowable hourly heat input.

Comment 55: Commenter 18023 states that not only do individual units see significant variability in
steady-state full load stack test results, these measurements are not representative of the variability that a
unit may experience on a continuous basis through all modes of operation, including startup, shutdown,
and malfunction, as may be measured by a PM CEMS.

Comment 56: Commenter 17881 states that it may not be possible to meet operating limits set at the
maximum routine operating load at other reduced loads and therefore the concept of conducting multiple
sets of performance tests at different operating loads under section 63.10007(c) is unworkable. The
commenter appreciates the EPA's attempt at recognizing that it may not be possible to meet operating
limits set at the maximum routine operating load at other reduced loads. For example, the commenter
asks the following: if an EGU were to test at 50 percent and 100 percent of rated capacity and establish
separate sets of operating limits, which set of operating limits would apply at any given time, and would
the operating limits established at 50 percent load apply to all loads < 50 percent capacity, < 75 percent
capacity (i.e., the mid-point between to two test conditions) or < 100 percent capacity?

Comment 57: Commenter 17881 suggests that a more realistic approach is to specify that the operating
limits only apply during those periods when the EGU is operating within a certain percentage of the
average load condition associated with the performance test. The commenter states that this approach
would be consistent with that taken by the EPA in 40 CFR 63, subpart ZZZZ - NESHAP for RICE. The
preceding rule requires that performance testing be conducted at 100±10 percent of rated load (see Table
la of subpart ZZZZ), and the operating limits established during testing (i.e., pressure drop for oxidation
catalysts) only applies when the unit operates at loads of 100±10 percent (see Tables lb and 2b of
subpart ZZZZ). Thus, states the commenter, this approach avoids the possibility of applying an
operating limit established at a specific operating load to loads not evaluated during the concurrent
performance test.

Comment 58: Commenter 17881 suggests another potential approach would be to use the performance
test and associated operating parameter values as verification of a parameter value or range based upon
control equipment vendor recommendations. For example, states the commenter, the vendor
recommendation for the pressure drop across a wet PM scrubber may be 35" to 40" water column (w.c.);
thus, the operating limit could be set at a minimum pressure drop of 35" w.c., and the performance test
could be used to verify that PM emission rates and or non-Hg HAP Metals emission rates at pressure
drops at or above the vendor recommendation comply with the applicable emission limits. According to
the commenter, this approach is very similar to the approach taken in 40 CFR Part 75, Appendix E,
which allows the use of a parametric monitoring approach for NOx emissions. Essentially, states the
commenter, stack testing is conducted to establish a relationship between NOx lb/MMBtu emission rates
and unit load; prior to conducting the stack testing, four parameters indicative of NOx emissions, along

236


-------
with the vendor recommended values or ranges for these parameters across the expected operating
range, are identified. During testing, states the commenter, the actual parameter values must be
consistent with the vendor recommended values or ranges, and the EGU must conduct ongoing
monitoring of the parameters following emission testing and verify that they remain consistent with the
vendor recommend ranges or values. According to the commenter, operating outside the vendor
recommended ranges or values results in a requirement to conduct additional testing.

Comment 59: Commenter 17718 states that under section 63.10007(f) the EPA should clarify whether
it will specify when and how performance testing is to be completed, beyond what is already proposed
in other sections of the regulatory language. The commenter states that other sections of the proposed
regulatory language specify when, how and under what conditions the performance testing is to be
conducted, and therefore, the proposed section 63.10007(f) appears unnecessary and should be
removed.

Comment 60: Commenter 19121 states that the proposed rule places limits on changing operating
modes and equipment in configurations different than those configurations used during a performance
test and that this would require sources to operate in every conceivable configuration during
performance testing. The commenter states that this could mean that performance testing could literally
take months to perform. As an example, states the commenter, the commenter enjoys high availability
due to redundancy of systems. For instance, states the commenter, the scrubber for each unit consists of
six modules; four modules are required for full load, two or three modules for start-up and low loads.
The commenter states that completing a performance test so that all operating configurations would be
considered acceptable under the proposed rule would necessitate numerous individual test arrangements,
and this would also be true for every burner configuration and baghouse compartment-in-service
rotations. The commenter states that the rule is proposing a performance test every 5 years; taking 6
months to complete a set of tests to meet the rule would be incredibly arduous and costly.

Response to Comments 50 - 60: We agree with commenters on the need for the regulation to define
more clearly what constitutes representative process operating load during performance testing. There
are generally three testing scenarios each with different definitions of representative operating
conditions. First, if the source uses CEMS (Hg, HC1, or SO2) to determine compliance with the limit that
applies over a 30-day averaging period, the rule need not specify any minimum process operating
conditions. Compliance is based on a direct measure of emissions in units of the standard for the entire
30-day averaging time for all periods the process operates regardless of load conditions.

The second scenario applies to the use of PM CPMS to demonstrate compliance with a PM or non-Hg
metals emissions limit. This includes continuous compliance with an operating limit based on
measurements from the PM CPMS rather than an emissions limit. That operating limit is derived from
data collected during a short term (three test run) performance test for either filterable PM measured
with Method 5 or non-Hg metals measured with Method 29. For the purposes of establishing a
representative operating limit, the rule will specify that the unit be operated at maximum normal
operating load conditions during the performance test period. We understand that actual maximum
normal operating load for a particular facility is unit dependent but we expect it will be generally
between 90 and 110 percent of design capacity. The rule will require the maximum normal operating
load condition be maintained during each test run only (e.g., a few hours at a time) allowing for some
operational flexibility for a performance test period that extends over more than one day.

The third scenario applies if the source owner elects to conduct frequent performance testing in lieu of
continuous monitoring. In such cases, the rule will specify that the unit be operated at maximum normal

237


-------
operating load conditions during each periodic (e.g., quarterly) performance test period. As noted above,
actual maximum normal operating load for a particular facility is unit dependent but we expect it will be
generally between 90 and 110 percent of design capacity. Maintaining this high load operating condition
need not be continuous during the time it takes to complete all of the performance testing but is required
only during each test run.

7. S02 CEMS issues.

a. Comments related to LEE (testing/monitoring).

Comment 61: Commenter 17800 states that in proposed section 63.10021(a)(ll)(iv) and (v), the EPA
proposes to require sources using PM CEMS to report "performance test data, except opacity data" and
"relative accuracy test audit data" electronically using ERT starting January 1, 2012 (FR Vol.76, No. 85,
p. 25,117) and section also requires the reporting of "performance test data, except opacity data" and
"relative accuracy test audit data" for LEEs (FR Vol. 76, No. 85, p. 25,117-18). According to the
commenter these provisions do not make sense because 1) EGUs using PM CEMS and LEEs do not
conduct "relative accuracy test audits" (RATAs); 2) PM CEMS are subject to different tests (RCAs and
RRAs); 3) LEEs comply by initially demonstrating applicability with emission tests and thereafter by
fuel analysis and therefore LEEs have no monitoring systems upon which to conduct RATAs; and 4)
with respect to "performance test data," the provisions are duplicative of a more general provision the
EPA proposes. Commenter states that the EPA needs to reconcile this language so it makes sense.

Response to Comment 61: The final rule does not contain the cited text. The recordkeeping and
reporting provisions in the final rule have been clarified to streamline reporting under this rule.

Comment 62: Commenter 17881 states that section 63.1002l(a)(17)(ii) makes no sense because the
whole point of being a LEE is to avoid stringent monitoring requirements (i.e., CEMS) and therefore if
not equipped with a CEMS how would one submit a CEMS performance test and RATA.

Response to Comment 62: The EPA agrees and the final rule has been amended to remove section
63.10002 l(a)(17)(ii).

Comment 63: Commenter 17767 states that the qualifications for the Hg LEE status are egregiously
costly because they would require stack testing company to sample for 28-30 days using Method 30B.
Moreover, the commenter states that the three 10-day runs wouldn't be achievable at their stacks due to
the scrubbed stacks' high moisture content which can foul the sorbent traps at week-long sampling
durations. The commenter strongly suggests the EPA revisit this portion of the proposed rule in
consultation with experienced outside experts.

Response to Comment 63: Under the final rule, all Method 30B tests are to be run on a 30 day basis.
The maximum run length for a sorbent trap is set at 15 operating days for both Method 30B and a
sorbent trap monitoring system. As long as the criteria for sampling within the calibration range of
Method 30B are met, the source may reduce the sampling runs to shorter than 15 days as long as the
total sample time of all runs is 30 days.

Comment 64: Commenter 17868 states that it is unclear whether the EPA intended the fuel input limit
on Hg, and additional operating limits on Hg controls and load apply to LEEs. The commenter states
that they should not.

238


-------
Response to Comment 64: The operating and fuel limits have been removed from the final rule.

Comment 65: Commenter 17868 states that LEE status should be available to new units.

Response to Comment 65: The final rule retains the proposed approach - no LEE for Hg for new units.
Given the emission rates established for these units, EPA does not believe the LEE option is appropriate.

Comment 66: Several commenters (17808, 17870, 18025, 18031) support the LEE approach but
recommend continuous compliance methods the commenters feel are less burdensome. Commenters
17870 and 18031 recommend instead of monthly fuel tests provide an option to conduct annual Method
30B test to demonstrate emissions are less than 10% or the applicable limit or less than 22.0 pounds per
year. If a LEE unit exceeds LEE limits, commenters propose that it revert back to more frequent
performance tests (e.g., quarterly, as recommended below); the subsequent year, if the unit can, again,
demonstrate LEE status through reduced utilization or a lower emission rate, it would return to annual
stack tests under the LEE provisions.

Response to Comment 66: The final rule establishes a process similar to that suggested by this
commenter. If a unit qualifies as an LEE for Hg, then annual testing is the only ongoing requirement.
However, if the unit tests at above 10% of the standard, the LEE status is lost and the source must move
to install, certify, operate and maintain an Hg CEMS or sorbent trap monitoring system. Specific testing
requirements will apply in the interim prior to the CEMS or sorbent trap monitoring system being
certified.

Comment 67: Several commenters (17808, 17870, 18025) also recommend allowing sources to
schedule their annual performance tests at any time during a 12-month cycle. The commenters state that
some of these LEEs may be smaller units with low capacity factors and may go several months without
operating, and allowing flexibility in scheduling stack tests will avoid unnecessary air pollution
emissions and reduce costs for these units operating well below the proposed standards. Additionally,
state the commenters, this would allow companies to align testing under this rule with existing state
testing requirements.

Response to Comment 67: The rule specifies a maximum interval between tests based on the cycle of
testing required, but does not specify a minimum. Of course, if tests are conducted close together, the
next scheduled test would be accelerated so that the maximum time between tests is not exceeded.

Comment 68: Commenter 17870 recommends that fuel testing be maintained as an alternate monitoring
method for LEE units; it is suggested that the frequency of fuel testing be reduced to each shipment of
oil received. According to the commenter, Hg concentration differences should be negligible in
comparison of Method 3013 and fuel analyses for oil-fired units.

Response to Comment 68: The operating and fuel limits have been removed from the final rule.

Comment 69: Commenters 17808 and 17870 state that for non-Hg HAP, LEEs have the option of
conducting an annual performance test to demonstrate that emissions are less than 50 percent of the
relevant emissions standard.

Comment 70: Commenter 18025 states that the rule should clarify the requirements for oil-fired and
coal-fired LEEs. The commenter believes this will help reveal where gaps may be occurring.

239


-------
Response to Comments 69 - 70: The final rule eliminates the fuel sampling requirements. For LEEs,
the rule requires annual Method 3 OB testing for Hg if the initial Method 3 OB test qualifies the unit as an
LEE for Hg. To qualify as an LEE for a non-Hg pollutant, the rule requires 3 years of performance tests
with each completed test below 50% of the emission standard for the applicable pollutant. If that occurs,
the source can switch to testing once per year for that pollutant but must revert to quarterly testing or
other monitoring options if a performance test exceeds that 50 percent threshold.

Comment 71: Commenters 17808 and 179227 request clarification that LEE status is available to all
subcategories and all HAP, not just Hg from coal units. According to the commenters, the discussion of
LEE status in section 63.10005 and in the preamble of the rule suggest that the EPA intends the LEE
provisions to apply to all subcategories, but monitoring requirements for other HAP and fuels are not
specified in Table 5.

Response to Comment 71: The EPA will clarify that the LEE status is available to all subcategories
and HAP.

Comment 72: Commenter 17927 asks whether if a source is determined to be a LEE and maintains its
status as a LEE in accordance with the requirements of the rule, the source will be required to install a
CMS if it does not have CMS for the applicable pollutants (e.g., PM, HC1, Hg).

Response to Comment 72: For Hg, the answer is no, assuming the source maintains its LEE status. For
PM and HC1, a CPMS or CEMS is not required under any condition. It is an option, but a source can
instead opt for quarterly testing.

8. LEE Applicability Threshold

Comment 73: Commenter 17785 recommends that for LEEs the EPA set fuel concentration standards
for Hg that are, based on the demonstrated Hg control efficiency in compliance test, equivalent to 22
lb/year of Hg emissions. According to the commenter, it does not seem appropriate to apply the fuel
sampling criteria for determination of compliance of LEE units, if these fuel limits would represent
emission lower than the LEE Hg threshold of 22 lb/year. The commenter believes their waste coal plants
are expected to continue to emit less than 5 lb/year, so it is likely that the imposition of a fuel Hg limit
based on average Hg or 90th percentile Hg would set an effective Hg emission limit that is likely less
than 10 lb/year. According to the commenter, this is an unnecessarily strict emission limit and may
cause a unit to lose its LEE status simply as a result of fluctuation of Hg in fuel.

Response to Comment 73: The final rule has removed the requirements for operational limits and fuel
sampling and analysis for LEE units. Compliance with LEE status will be achieved through annual
performance tests.

Comment 74: Commenter 17620 agrees that units that have demonstrated an ability to consistently limit
emissions substantially below applicable limits should be eligible for reduced monitoring. However, the
commenter recommends that the thresholds for reduced testing be based on a demonstrated record of
performance over several years, be accompanied by parametric monitoring and/or compliance assurance
monitoring and be set at more protective levels. The commenter states that the EPA has proposed to
allow reduced testing for sources based on the results of a single test and has proposed to allow reduced
testing where the source's emissions are as high as 70% of the applicable limit, and the EPA's proposal
would allow a unit to qualify for reduced testing for Hg if the source's emissions were either less than
25% of the applicable limit or less than 22 lb/year. In contrast, states the commenter, in calculating the

240


-------
Hg MACT floor, the EPA asserts that even the best performing units can reasonably expect year-over-
year stack test results to vary by a factor of 50 because of statistical variability, operational variability,
measuring system variability and variability in fuel. The commenter states it is convinced that year-over-
year compliance testing of well-performing units will demonstrate the variability that the EPA asserts in
its MACT floor proposals but suggests that the EPA be consistent in its treatment of these issues.

Response to Comment 74: The LEE provisions demonstrate the Agency's desire to provide incentives
for owners or operators to provide additional emissions reductions. The provisions offer easy entry, as
the initial performance testing results can be the basis for qualifying, but strenuous maintenance
requirements, for the results of every test conducted for any reason must meet the qualifying
requirements. Should those requirements not be met by just one subsequent test, LEE status is lost and
the source owner must provide qualifying data from three years of results before becoming eligible for
LEE status. LEE status for Hg is achieved through a 30-day performance test repeated annually, that
documents emissions are less than 10% of the standard or less than 29 lb/year. If results from a single
test are above that threshold, the source will have to use Hg CEMS or a sorbent trap monitoring system.
For non-Hg LEE status, the source must demonstrate that test results are below 50% of the emission
limit. As mentioned before, should test results from an EGU show emissions above the LEE threshold
for any reason - including variability - LEE status is lost

Comment 75: Commenter 17873 asserts that the LEE standard for Hg (10% of the MACT standard) is
low and impractical. According to the commenter, the proposed limit of 0.12 lb/MMBtu is near or below
the in-stack method detection limit, and it will be very difficult to confidently prove compliance under
any testing regimen. The commenter states that the LEE standards for other HAP are 50% of the MACT
standard. Commenter states that while it understands the heightened focus on Hg, the EPA has not
sufficiently demonstrated the need for a LEE standard threshold less than that for other HAP, and
therefore propose a consistent LEE Hg standard of 50% of the Hg MACT standard (or 0.06 lb/TBtu).

Response to Comment 75: The EPA disagrees with the commenter. Method 30B has been shown to be
capable of measuring Hg catches down to 1 ng within QA/QC criteria of the method. With increased
time as allowed in LEE testing, Method 30B is technically capable of demonstrating emissions at the
LEE threshold. In addition, the mass alternative provides another option for demonstrating LEE status.

Comment 76: Commenter 17767 states that the 22 lb/yr Hg threshold for LEEs was set using fifth
percentile of the 1,091 operating units (5% of the total mass being determined as a "reasonable cut
point" during the CAMR development process). Commenter presumes that, in light of the Hg
calculation errors discovered in the proposed rule's foundational data since its publication in the Federal
Register, the agency will revisit the lb/yr cut-off calculation at the reasonable fifth percentile level.

Response to Comment 76: The agency disagrees with the comment, for the Hg LEE threshold was
determined independently from the proposed rule's Hg limit. The rule contains no change to the Hg LEE
threshold.

Comment 77: Several commenters (17754, 17812, 17838, 18963) state that LEEs with Hg emissions
below 50% of either of the proposed LEE thresholds should be provided an option to demonstrate
continuous compliance through annual stack testing, and should not be required to conduct monthly fuel
analyses so long as the fuel supplier does not change. According to the commenters, annual testing could
consist of three 120-minute test runs performed using EPA Method 30B. Sources emitting at very low
Hg emission rates are highly unlikely to show emissions that would exceed the LEE threshold.

241


-------
Response to Comment 77: The final rule has been amended to remove the fuel sampling and analysis
requirement of the LEE option. In lieu of fuel sampling, annual LEE performance testing will be
required.

Comment 78: Several commenters (17754, 17838, 18963) state that an alternative to LEE compliance is
to use a fuel-factor based approach. According to the commenters, the EPA could revise the specific
fuel-factor based approach currently required under the proposed rule. The commenters believes that the
requirement to use the 90th percentile confidence level to determine the operating limit for Hg is
improper, because the use of such value could cause a LEE to lose its LEE status, even though the unit's
actual Hg emissions remain substantially below the LEE thresholds. The commenters recommend a four
step approach:

Step 1: Conduct an initial performance test (and every 5 years thereafter) to demonstrate the unit's LEE
status and during the performance test determine and record the average control efficiency achieved over
the three test runs. The initial performance test (for demonstrating LEE status) would be conducted over
a 28-30 day period; subsequent performance testing, on a 5 year cycle, should consist of three 120-
minute test runs, performed using Method 3OB.

Step 2: Determine the Hg content in the fuel on a monthly basis.

Step 3: Calculate the average Hg content in the fuel on a quarterly basis (i.e., by averaging the Hg
content levels measured during the 3 months comprising the quarter).

Step 4: Apply the control efficiency determined during the stack test to the quarterly average Hg fuel
content. If the projected annual emission rate (calculated by multiplying the control efficiency
determined during the performance test by the Hg fuel content) is less than or equal to 50 percent of the
22 lb/yr LEE threshold (i.e., 11 lb/yr), then the owner/operator remains subject to this process for
demonstrating that the facility continues to qualify as a LEE. However, if the calculated fuel factor value
is greater than 11 lb/yr, then the owner/operator shall conduct a stack test to demonstrate that the unit's
Hg emissions are in fact below the 11 lb/yr level. If the unit's actual Hg emissions determined from such
stack testing remain less than or equal to 11 lb/yr, then the owner/operator remains subject to this
process for demonstrating that the facility continues to qualify as a LEE. If the unit's actual Hg
emissions are greater than 11 lb/yr, but less than 22 lb/yr, then the owner/operator shall thereafter
comply with the continuous compliance demonstration requirements for LEEs with emissions below the
22 lb/yr threshold for Hg (i.e., such unit would no longer qualify as a "very low emitting EGU"). To the
extent that a facility thereafter demonstrates through performance testing that its projected annual Hg
emissions are less than 50 percent of the LEE threshold of 22 lb/yr, then the facility could return to very
low emitting EGU status, and demonstrate continuous compliance in accordance with the foregoing
methodology. In other words, simply because a single stack testing result suggests that the facility's
annualized Hg emissions could exceed 11 lb/yr, the facility should not be perpetually precluded from re-
establishing very low emitting status.

Response to Comment 78: The final rule has been amended to remove the fuel sampling and analysis
requirement of the LEE option. In lieu of fuel sampling, annual LEE performance testing will be
required.

Comment 79: Commenter 17927 questions whether an EGU that fires coal or solid-oil derived fuel that
has not determined if it qualifies for LEE EGU status per the proposed rule have the option of any of the

242


-------
testing options listed in Table 5 (performance testing, Hg CEMs, sorbent trap monitoring system, or 28-
30 day LEE testing) for the initial performance test.

Response to Comment 79: Initial compliance for coal or solid-oil derived fuel may only use the Hg
CEMS, sorbent trap monitoring system or LEE testing options.

Comment 80: Commenter 17927 requests that the EPA clarify whether an existing coal or solid-oil
derived fuel-fired unit the performs a 1-day performance test per Table 5 after the final rule is published
and within the 3-year compliance deadline for affected units have the option of complying with the LEE
requirements.

Response to Comment 80: LEE requirements for Hg must be met with a 30 day Hg performance test.
For other pollutants, LEE status requires a series of periodic tests that show emissions are routinely
below 50% of the standard for the applicable pollutant.

Comment 81: Commenters 17627 and 17718 believe that the EPA should reconsider the frequency and
types of monitoring that are appropriate for various subcategories and provide an exemption for low
capacity factor and LEE units.

Response to Comment 81: The EPA has reconsidered and amended the final rule to alter the frequency
and monitoring requirements for low capacity and LEE units.

Comment 82: Commenter 17781 states that while it is not unreasonable to set a qualification level, the
EPA has provided no rationale for setting different thresholds for Hg (10%) and all other HAP emission
limits (50%>).

Response to Comment 82: Because of the evidence of widespread contamination with a risk of
significant adverse health and environmental effects associated with Hg emissions and because Hg has a
high degree of persistence, EPA believes that it is appropriate to set a more precautionary threshold for
allowing a source conduct periodic emissions testing in lieu of monitoring continuously for compliance
with the Hg emissions limit.

As mentioned elsewhere in this document and rule preamble, mercury is a powerful neurotoxin that
persists in the environment indefinitely and its emissions warrant special attention.

Comment 83: Several commenters (17781, 17838, 17902) state LEE units that operating outside the
operating limits established during the most recent performance test should disqualify the unit from LEE
status. See section 63.10006. The commenters recommend that operating outside the operating limits
established during the most recent performance test should trigger a requirement to conduct a timely
LEE qualification re-test based upon an expanded operating limit (consistent with the original operating
limit excursion). Commenter 17781 states that if the results of the LEE qualification re-test indicate that
the unit continues to qualify for LEE status (i.e., meets section 63.10005(k)(l) and (2)), then the EGU
should maintain its LEE status; if the testing does not show that the EGU continues to meet LEE status,
then the EGU should be subjected to enhanced monitoring (i.e., be required to meet the provisions of
section 63.10006(c)(1) and (2)).

Response to Comment 83: The final LEE provisions and other final monitoring requirements do not
provide for this suggestion. The only parameter monitoring that applies is a PM CPMS, and the
expectation if that I used is that a source is unlikely to opt for LEE status after the CPMS is installed.

243


-------
Comment 84: Commenter 18014 states that the fuel sampling requirements for LEE units are
ambiguous and provide no compliance value since the rule does not require the establishment of a fuel
input operating limit. According to the commenter, the requirements do not address single-fuel units,
changes in fuel type, or units that burn or co-fire multiple fuels, and presumably, LEE units would
follow an analogous procedure to non-LEE units and reassess the ability to meet LEE status based on
the new fuel type/blend. According to the commenter, this would require sources that burn multiple fuel
types or blends to establish a fuel-input operating limit during the initial compliance demonstration. The
commenter recommends that consistent with the non-LEE requirements, the EPA should remove the
arbitrary monthly sampling requirement and allow sources to conduct fuel sampling only when there is a
change in the fuel type and that for single-fuel units, the EPA should specify that these units are not
required to comply with any of the fuel sampling requirements.

Response to Comment 84: The final rule has been amended to remove the fuel sampling and analysis
requirement of the LEE option. In lieu of fuel sampling, annual LEE performance testing will be
required.

Comment 85: Several commenters (19536, 19537, 19538) state that the EPA should discard the
proposed "Low Emitting Units" monitoring protocols. According to the commenter, because the EPA's
standards are based upon a 99% UPL a majority of plants should be able to generate test data sufficient
to claim such "low emitting" status. The commenter states that as summarized in Table X-l, the EPA's
proposed MACT standards exceed the tested emissions of the plants for which the EPA has data by the
ratio greater than 2 for all non-Hg HAP (i.e., the tested emissions are below 50% of the standard), and
greater than 10 for Hg (i.e., tested emissions are less than 10% of the standard). As a result, states the
commenter, almost all existing and new units will likely be able to exempt themselves as LEEs; in
combination, the EPA's variability adjustments and LEE exemption allow most units to avoid any
significant monitoring of emissions.

Comment 86: Commenter 18487 urges the agency to either discard its "Low Emitting EGU"
provisions, or to substantially revise them; if the emissions variability asserted by the agency exists, the
threshold conditions required for qualification as a "low emitting" unit provide no significant assurance
that emissions will remain below the proposed standards.

Response to Comments 85 - 86: The agency disagrees with the comment to discard the incentive for an
EGU owner or operator to seek LEE status. While emissions data collected as a result of the ICR and
adjusted using the UPL calculation shows an EGU's potential variability, well-operated EGUs - such as
those qualifying for LEE status - are expected to have much less variable emissions. The Agency
believes that the requirement to revert to the original monitoring frequency should subsequent emissions
testing show the EGUs no longer meet LEE status will keep source owners or operators interested in
maintaining LEE status.

Comment 87: Commenter 17402 supports the LEE alternative compliance with some modifications.
The commenter recommends that any facility that either significantly over-complies with the emissions
standards, or is overall a low emitter by mass in the case of Hg, should be afforded significant leeway in
terms of performance testing and fuel analysis. Most of the commenter's Illinois facilities installed ACI
controls in years 2008 and 2009, and have reduced Hg emissions below 22 lb/yr. The commenter states
that such plants conduct semiannual performance stack tests utilizing Method 30B for compliance, and
use sorbent traps for tracking ACI effectiveness. According to the commenter, the rule should be clear
that low emitters can use Hg monitors to track performance, rather than for compliance. The commenter
notes that this approach is consistent with the EPA's long history of exempting low-emitting sources

244


-------
from monitoring or allowing those sources to use less rigorous and lower cost monitoring technology,
rather than requiring continuous monitoring. The commenter states that the EPA first used a de minimis
exemption to exempt certain units from Acid Rain CEMS monitoring regulations in 1993 and that
similarly, in 1998 the EPA included low emitter provisions with inventory-based "cutoff points" for S02
and NOx emissions.

Response to Comment 87: The Agency believes the rule provides owners or operators of LEEs with
significant leeway concerning maintaining LEE status, given that Hg emissions testing need only occur
annually and non-Hg emissions testing need only occur once every 3 years. With that incentive for
reduced testing frequency comes the responsibility for ensuring units continue to meet LEE status.

While the agency expects owners or operators will want to ensure proper operation by monitoring
control device effectiveness, along with other relevant items, the agency also expects adherence to LEE
status requirements, meaning that should measured emissions exceed the LEE threshold, LEE status
would become revoked.

Comment 88: Commenter 17902 recommends that the EPA should clarify that for LEE qualifiers it
exempts units from a CEMS requirement as well as bi-monthly performance testing. Also it should not
require monthly fuel analysis- this should only be required when there is a fuel switch or allow for
obtaining the data from the fuel supplier. For example, states the commenter, a unit could qualify for
LEE for non-Hg metals by being less than 50% of the total PM limit (even if HC1 or Hg emissions are
not LEE status). According to the commenter, this unit would not be required to install a PM CEMS and
would require fuel analysis only when there is a fuel change plus repeat the performance test every 5-
years.

Response to Comment 88: LEE status is unique to each regulated HAP. A source may achieve LEE
status for one HAP while not for another.

9. LEE fuel sampling issues.

Comment 89: Commenters 17767 and 17807 express concern over the fuel sampling and the potential
for variability. Commenter 17767 states that there is no discussion of allowable tolerances to the Hg,
chlorine, and HAP Metal content limits set for ongoing qualification for LEE status. The commenter
states that it is unreasonable to assume that, given the natural variability within even the same coal seam
as well as the error of the analysis methods, the constituents will be consistently below the
concentrations observed during the performance testing; this would make the LEE methodology
undependable and functionally unworkable. Commenter 17807 states that a single date point is not
sufficient to demonstrate emissions in excess of the LEE. Commenter notes that in order to provide
assurance that the fuel profile is meeting the limits set during the initial compliance test, coal would
need to be stored for some period of time prior to burning. According to the commenter, it would be
impractical and environmentally imprudent to store coal for extended periods of time just to wait for
laboratory analytical results.

Comment 90: Commenter 17928 states that under the LEE an oil analysis required to comply with the
input-based standards requires very low detection limits not typically available in national labs.
According to the commenter, there are a limited number of laboratories that do these tests to the limits
of detection needed; these analyses are too costly to have performed on the regular basis proposed in the
rule; and the oil-fired units typically have low capacity factors, another factor that argues against regular
oil testing.

245


-------
Comment 91: Commenter 17800 states to qualify for LEE status for Hg emissions the test Method 30B
is a vapor phase only test method and does not account for any particle bound Hg emissions. The
commenter recommends that an initial performance test for Hg emissions include an accounting of any
particle bound Hg; an option would be to demonstrate that total Hg emissions is less than 10% of the Hg
emission limit or less than 22 lb/yr using a test method that measures total Hg. The commenter states
that if the particulate bound Hg is 5% or less than the total, subsequent testing could measure only the
vapor phase Hg emissions; if EPA Reference Method 29 or ASTM Method D6784-02 (2008) is used to
determine total Hg emissions, only three 1-hour test runs would be required.

Comment 92: Commenter 17805 does not believe it is necessary to sample larger volumes during stack
testing to comply with LEE status. The commenter states that current stack test methods should be
sufficient for determining compliance with LEE status and a unit is still required to conduct monthly
fuel sampling per section 63.1 0006(c) that would serve to demonstrate coal variability. Commenter
believes it is burdensome to require parametric limits to be applied to LEE units as well, since existing
controls for other pollutants, such as SO2 in consideration of a potential HC1 LEE unit, would be
adjusted as appropriate for the pollutant emissions that are monitored by the CEMS. According to the
commenter, this would serve to keep HAP emissions consistent, and again, fuel analysis is conducted
monthly for LEE units to evaluate potential increases in constituents that might result in higher
emissions.

Comment 93: Commenter 18539 is concerned that the proposed rule does not adequately address the
operating characteristics of fuel-flexible units. According to the commenter, the nature of monitoring
requirements, both initial and every 5 years, in addition to parametric monitoring, will hinder many sites
from using multiple fuel sources and types where there was not a restriction before this rule. The
commenter states that this aspect will not only diminish the operational and financial flexibility of the
facility, but it has the potential to virtually prohibit large segments of fuel suppliers that have elevated
metals and other HAPS, and all the while there may not be any economical substitute for the unusable
fuel, thus causing extreme localized economic and employment losses.

Response to Comments 89-93: The final rule has removed the requirements for operational limits and
fuel sampling and analysis for LEE units. Compliance with LEE status will be achieved through
performance tests. Increased sampling volumes may not be necessary, but must be sufficient during LEE
testing such that the in stack detection limit is less than the LEE threshold. See responses to comments
elsewhere in this document relative to particulate Hg measurements.

10. Belt sampling.

Comment 94: Commenters 17730 and 17775 state that section 63.10008 includes very specific
requirements for collecting composite fuel samples. The commenters state that for belt sampling, the
rule requires that the belt be stopped. Commenters believe that this requirement is unreasonable because
it would not allow for the use of continuous belt samplers; many belts cannot be restarted with coal on
them because the belt is too heavy for the motor to start. The commenters state that for sampling piles or
trucks, the rule requires (among other things) use of a "square shovel," collection of samples at a depth
of exactly "18 inches," collection at five locations "uniformly spaced over the surface of the pile," and
breaking of pieces larger than exactly 3 inches (proposed in section 63.10008(c)(2)(ii) and (d)). The
commenters note that they do not object to the intent behind these proposed requirements, representative
samples can be taken with shovels of other shapes, at depths greater or less than 18 inches, and without
measuring the actual size of individual coal pieces. The commenters believe these requirements are
excessively prescriptive and that the EPA should remove the prohibition on moving belt samplers, and

246


-------
re-examine and moderate the pile sampling requirements to provide more realistic criteria (e.g., use the
same shovel for all samples, collect samples at a uniform depth of approximately 18 inches, and break
apart large pieces (e.g., pieces greater than 3 inches).

Response to Comment 94: The final rule has removed the requirements for operating and fuel limits
with the exception of a PM CPMS.

11. Sorbent trap.

Comment 95: Commenter 17870 supports the use of sorbent traps for units not equipped with CEMS.
Response to Comment 95: The EPA thanks commenter for its comment.

Comment 96: Several commenters (17696, 17775, 17868, 17800) state that the EPA should provide an
explanation for the difference in the days the sorbent trap is used. According to the commenters the rule
provides 14 days for non-LEE units and 10 days for LEE units.

Response to Comment 96: The final rule will be amended to allow 15 days for LEE unit performance
tests.

Comment 97: Commenter 17696 does not believe that there should be any limit on the number of days
that sorbent traps may be used to sample Hg. The commenter has periodically used sorbent traps over
the past 2 years at five facilities in preparation for continuous Hg emissions monitoring requirements
that will become effective next year under the Illinois Mercury Rule, 35 111. Admin. Code part 225,
subpart B. In the commenter's experience, while sorbent traps are routinely changed out within 14
operating days, there is no reason to invalidate a pair of sorbent traps simply based on the duration of
their use in the event unforeseen circumstances prevent removal of the traps on schedule. The
commenter states that notably, the Illinois Mercury Rule does not restrict the number of days a sorbent
trap may be used. (See 35 111. Admin. Code Part 225, Subpart B, App. B, Continuous Emission
Monitoring Systems for Mercury, Exhibit D, Quality Assurance and Operating Procedures for Sorbent
Trap Monitoring Systems.) Commenter states that such a prescription on the duration a trap may be used
is unnecessary because the length of time a trap may sample varies from stack to stack based on SO3
concentrations and other miscellaneous factors.

Comment 98: Commenter 17696 states that the determinative factor for the validity of sorbent traps
should be the QA/QC criteria already in place for the sorbent trap monitoring method, and not the
duration of use. If a trap samples for too long, states the commenter, it will either fail the breakthrough
or spike performance criteria (see proposed App. A, 1.5.2.1 (requiring compliance with 40 CFR Part 60
PS 12B QA/QC criteria, which includes spike recovery and vapor phase breakthrough specifications)).
According to the commenter, those QA/QC criteria are, by themselves, a powerful incentive not to
sample for too long. However, states the commenter, if an EGU is forced to use a sorbent trap to sample
for a longer duration than expected because of, for example, bad weather or mechanical problems with
the stack elevator, the EGU should still be able to use the trap data if the QA/QC criteria are met; the
duration of use does not itself adversely affect the performance of the trap or the validity of the
monitoring result. However, states the commenter, if the EPA does not eliminate the proposed duration
limit on use of sorbent traps, the EPA should revise section 63.1 0005(k)(3) to allow use of sorbent traps
for up to 14 operating days consistent with Appendix A, 5.2.1.

247


-------
Response to Comments 97-98: The final rule has been amended to allow 14 days for Hg LEE
testing. Issues extending the sample time by a day such as bad weather or mechanical issues can be
handled on a case-by-case basis through a minor alternative monitoring requests.

Comment 99: Commenter 17927 requests clarification as to whether an existing coal or solid oil-
derived unit that is found not to be an LEE is required to install a sorbent trap monitoring system to
demonstrate continued compliance.

Response to Comment 99: The source would be required to install sorbent trap monitoring system or
Hg CEMS.

12.	Oil-Fired testing.

Comment 100: Commenter 17818 states that they agree with the EPA's proposed requirement for units
firing residual liquid oil fuels. However, the commenter believes that the testing requirements are
excessive for units that utilize distillate liquid oil fuel, and that fire no residual fuel oil; after the initial
performance test such units should be eligible for compliance through fuel testing and monitoring
requirements similar to that proposed by the EPA for "limited-use liquid oil combustion units." The
commenter states that that there are relatively few variables in distillate oil combustion practices for a
given unit design and that there is relative consistency in distillate fuel oil quality and chemical
composition such that there would be little variability in the emission of HAP metals, HC1, or HF.

Comment 101: Commenters 17716 and 18498 state with respect to the EPA solicitation of comment on
"a limited-use subcategory to account for liquid oil-fired units that only operate a limited amount of time
per year on oil and are inoperative the remainder of the year" (76 FR 25027/3) that limited operation
may preclude the ability to conduct stack testing. According to the commenters, limited operation that
precludes the ability to conduct stack testing is not a phenomenon limited to only liquid oil-fired units;
timelines for completing subsequent performance tests for all units should be adjusted to account for the
operating status of the unit.

Comment 102: Commenter 18444 states that new and existing EGUs using distillate oil, especially
ultra-low sulfur oil, which is almost as clean as natural gas, do not need a particulate emission limit or
testing to demonstrate compliance. According to the commenter, periodic opacity testing is not needed
either; a no visible emission standard is achievable and reasonable for ultra-low sulfur distillate oil.

Response to Comments 100 - 102: The final rule has been amended to reduce all liquid oil-fired EGU
performance testing to quarterly and to subject limited use (capacity factor less than 8% in a 24 month
block average) sources to work practice standards in lieu of numeric emission limits. In addition, the
fuel sampling and analysis requirements have been removed. The only fuel-related provision is an
option for liquid oil-fired units to demonstrate compliance with the acid gas standards by documenting
that fuel moisture content remains no greater than 1.0%. This demonstration is based on monitoring
results or fuel supplier certifications.

13.	Measurement issues.

Comment 103: Commenters 17724 and 17729 state that for new units the limits are so low that
adequate test methodologies to demonstrate compliance do not exist. According to the commenters,
without accurate testing methodologies, contractors will not guarantee that potential emission control
technologies will meet the proposed standards; without accurate test methodologies and vendor

248


-------
guarantees, financing of new facilities will be virtually impossible to secure; and this will effectively
preclude the construction of any new coal-based units. Commenter 17729 notes that this will affect the
balance of fuel diversity in the energy supply.

Response to Comment 103: The final rule new source emission limits have been adjusted to three times
the RDL to ensure the required test methods can demonstrate compliance.

Comment 104: Commenter 17716 states that in section 63.7520(d) the EPA specifies a minimum
sampling time of four hours for each test method, following the procedures used to establish the MACT
floor data. Commenter asserts that 4 hours seems excessive for certain pollutants. According to the
commenter, the required sampling times should be reevaluated and/or alternative minimum sample
volumes should be provided for each method, taking into account representative analytical detection
limits and emissions standards that are fully adjusted for non-detect values.

Response to Comment 104: The EPA has reviewed the final emission limits, sample volumes and RDL
to ensure that a realistic sample volume and duration is provided. Sources may also request alternative
sample volumes as outlined in 40 CFR 63.7.

Comment 105: Commenter 17718 states that the EPA should clarify the specific testing (initial and
subsequent) and monitoring requirements for a unit with bypass capability. Specifically, states the
commenter, the EPA should clarify whether initial testing of the bypass emissions need to be tested
within the 180-day timeframe described in the proposed language. Alternatively, states the commenter,
setting a firm testing timeframe on bypass stack emissions seems overly burdensome. According to the
commenter, creating emissions (and incurring costs) by switching a unit into bypass mode that would
not otherwise have been used simply in order to perform emission testing appears to create unnecessary
burden.

Response to Comment 105: Due to the potential for technical issues with the use of CEMS or a PM
CPMS on the bypass stack, the final rule provides the option to either install and operate a CEMS or PM
CPMS in the same manner as a main stack, or to treat hours in which the bypass stack is used as monitor
downtime.

14. Fuel sampling issues.

Comment 106: Commenter 17716 suggests that the fuel sampling, analysis and calculations proposed in
section 63.10021 could be applied for uncontrolled units and believes that for controlled units, annual
testing is sufficient to demonstrate proper operation of control devices. Commenter 17716 believes the
provisions for fuel sampling, analysis, and calculation of expected emission rates proposed in section
63.10021 should apply to liquid oil-fired sources.

Comment 107: Commenter 17402 states that the EPA should allow compliance through annual
performance testing rather than bimonthly or monthly, when combined with monthly fuel sampling for
facilities that use a single fuel type. According to the commenter, data in the docket indicate that over
the long term, facility compliance is fairly consistent despite the potential for variability in fuels and
operations to affect emissions levels. The commenter states that the EPA should allow facilities to
comply with the performance testing requirements on an annual basis by coupling the less frequent stack
testing with more frequent fuel sampling.

249


-------
Comment 108: Commenter 17402 states that the EPA should clarify when fuel sampling requirements
apply. For example, states the commenter, fuel sampling should not be required for units that employ
CEMS. According to the commenter, for units that only burn one type of fuel, sampling should only be
required monthly if being used as part of a continuous compliance program, as the variability impact is
limited. Most importantly, states the commenter, the EPA should not penalize units that burn low
contaminant fuel by setting their fuel limits based on their average fuel content during the performance
tests. According to the commenter, instead, the EPA should set the fuel limit based on HAP reduction
performance of the unit, and set the fuel contaminant level at one that guarantees compliance with the
fuel limit taking into account the standard variability of HAP in that source's fuel.

Comment 109: Commenter 17730 states that the EPA should moderate the alternative procedures in
proposed section 63.10008. The commenter states that all fuel analysis under the rule must be conducted
according to an approved site-specific plan and according to specific procedures for sampling,
preparation, and analysis. According to the commenter, the EPA's proposed requirements are in many
instances overly prescriptive; the primary objective should be to obtain fuel samples that are
representative of the fuel that is being combusted. According to the commenter, because there is so
much diversity in how fuel is received, stored, and processed at individual facilities, as well as what is
actually contained in the mine, the EPA needs to allow more flexible procedures to accomplish the
primary objective. The commenter states that under proposed section 63.10008(b)(1), the proposed plan
must be submitted to the Administrator at least 60 days before the fuel analysis. Because some of the
information required to be included may change from analysis to analysis the commenter assumes the
EPA will require a new plan. For example, states the commenter, the plan must include identification of
all fuel types anticipated to be combusted and whether the source or fuel supplier will conduct the
analysis (proposed in section 63.10008(b)(2). The commenter states that although it might be possible to
submit that information 60 days in advance of the initial demonstration and receive approval before
conducting the analysis, it may not be possible for subsequent analysis in response to changes in fuel
type or fuel mixtures (since those might occur with less notice or planning). According to the
commenter, the requirement to submit a new or revised plan also makes little sense if monthly analysis
is required. The commenter believes that the EPA should either remove the requirement for advance
submittal and approval of a plan after the initial compliance demonstration, or remove the requirement
to include in the plan information that might change.

Response to Comments 106 - 109: The final rule has removed the requirements for operating and fuel
limits with the exception of a PM CPMS. Compliance with emission limits will be shown with periodic
(quarterly) performance testing, CEMS, or a combination of annual emission testing and PM CPMS.

15. Fuel limits.

Comment 110: Commenter 17705 encourages the EPA to limit the requirement to establish maximum
fuel inputs to sources that are uncontrolled and solely relying on fuel analysis to demonstrate
compliance with a numeric standard. The commenter states that the characteristics of fuel, in particular
coal fuel, can vary between shipments, so it is problematic to establish any type of maximum value
based on a one-time, short-term performance test, and further, for units that are controlled, relying on a
fuel input limit does not adequately account for emissions reductions achieved by the control devices.
According to the commenter, for controlled units that do not elect to use CEMS to demonstrate
compliance, it would be more appropriate to establish parametric monitoring for the control devices
(coupled with period performance testing) than unnecessarily constrain fuel supplies through non-
representative "maximum" fuel inputs.

250


-------
Response to Comment 110: The final rule has removed the requirements for operating and fuel limits
with the exception of a PM CPMS. Compliance with emission limits will be shown with periodic
(quarterly) performance testing, CEMS, or a combination of annual emission testing and PM CPMS.

16.	CEMS only.

Comment 111: Commenter 17715 states that it is not clear in the proposed rule that installing and
operating CEMS for the regulated HAP and surrogates will relieve a source of the burden of also
monitoring compliance with operating limits on control equipment based on a performance stack test.
According to the commenter, the EPA should require no additional proof of compliance than a properly
calibrated and installed CEMS would provide, and the EPA should format both the language and tables
in the rule to clarify its intent as it relates to CEMS used for demonstrating compliance.

Response to Comment 111: No other monitoring is required if a source uses a CEMS to demonstrate
direct compliance with an emission limit (including the SO2 surrogate limit for HC1).

17.	Section 63.10007(a) Site Specific Test Plan.

Comment 112: Commenter 17718 states that the EPA should provide guidance on what should be
included in a site specific test plan as mentioned in proposed regulatory language of 40 CFR
63.10007(a) and referenced to 40 CFR 63.7(c). According to the commenter, the development of
external QA programs with testing firms and laboratories (especially if multiple testing firms and
laboratories are needed) has the potential to become extremely burdensome without clearer guidance.

Response to Comment 112: The EPA has already issued a guideline document for the preparation of
site specific emission test plans. The document can be found at http://www.epa.gov/ttn/emc/guidlnd/gd-
042.pdf

18.	CPMS comments.

Comment 113: Commenter 1775 states that section 63.10010(h) sets out requirements for CPMS and
the previously proposed PS 17 would apply to CPMS. 73 FR 59,983 (Oct. 9, 2008). The commenter
objected in the PS 17 rulemaking to the proposed application of that specification to future performance
specifications without revision of the individual subpart. See UARG Comments on Proposed
Performance Specification And Quality Assurance Requirements For Continuous Parameter Monitoring
Systems (February 5, 2009), EPA-HQ-OAR-2006-0640-0064. The commenter states that whatever
specifications are necessary to support this rule, they must be proposed and promulgated in this
rulemaking.

Response to Comment 113: This is no longer applicable except to the extent PS 17 would apply to a
PM CPMS under this rule. Given that PS 17 is not yet final, this issue is best addressed in the response
to this concern in the context of the PS 17 rulemaking, not in this rulemaking, given that the issue
extends to all promulgated NESHAP standards with a parametric monitoring system potentially subject
to PS 17.

Comment 114: Commenter 17775 states that the rule proposes various installation operation and
maintenance requirements for "flow monitoring systems," "pressure monitoring systems," and "total
secondary power monitoring systems." According to the commenter, several of these proposed
requirements are unnecessary or unclear: first, with respect to flow monitoring systems, depending on

251


-------
the fluid being measured, many systems do not use flow meters due to reliability issues, corrosion, or
composition. Instead, these processes frequently use constant rate pumps. The commenter states that
these pumps have a known capacity given their specific application and are either "on" or "off." As an
example, states the commenter, scrubber module slurry pumps operate in this manner; the reported
scrubber slurry flow rate is simply based on the number of pumps in service. According to the
commenter, the EPA should make clear that flow monitoring systems are not required for any CPMS
and that systems that use constant rate pumps are not subject to performance specifications (see
Technical Memorandum from Richard McRanie, McRanie Consulting, "Comments on the Proposed
Utility MACT Rule - Operating Parameters" (July 2011) (Attachment 11) at 18).

Response to Comment 114: The final rule has removed the requirements for operating and fuel limits
with the exception of a PM CPMS.

Comment 115: Commenter 17775 states that the section 63.10010(h)(2)(i)(C) requirement to
"Minimize the effects of swirling flow or abnormal velocity distributions due to upstream and
downstream disturbances" is unnecessary and extremely vague. According to the commenter, the
requirements in proposed subsections (A) and (B) - to properly locate the flow sensor and to use a sensor
with a sensitivity no greater than two percent of the expected flow rate - are adequate. The commenter
states that the term "minimize" is not sufficiently objective to be meaningful in this context, and more
objective requirements (e.g., some number of diameters downstream of a flow disturbance) might not be
possible to meet.

Response to Comment 115: The final rule has removed the requirements for operating and fuel limits
with the exception of a PM CPMS.

Comment 116: Commenter 17775 states that the evaluations under section 63.10010(h)(2)(i)(D) should
specifically allow for procedures that include process trending and comparisons that can indicate the
flow monitor is performing properly (similar to the fuel flow to load concept in Part 75, Appendix D
section 2.1.7). According to the commenter, operators should not necessarily be required to ship meters
off to get NIST traceably certified each year.

Response to Comment 116: The final rule has removed the requirements for operating and fuel limits
with the exception of a PM CPMS.

Comment 117: Commenter 17775 stated that with respect to pressure monitoring systems in section
63.10010(h)(2)(ii)(B), the requirement will be difficult to interpret as a regulatory requirement. The
commenter states that the requirement in subsection (A) to provide a representative location is sufficient;
however, the EPA also proposes to require that EGUs "Use a pressure sensor with a minimum tolerance
of 1.27 centimeters of water, or a minimum tolerance of 1 percent of the pressure monitoring system
operating range, whichever is less" (proposed section 63.10010(h)(2)(ii)(C). According to the
commenter, this should read, "whichever is less restrictive." If a source is using a 0 to 30 psig gauge for
some purpose, the 1.27 cm requirement would be the lesser error, states the commenter, but it would be
a 0.06 percent error. The commenter does not believe this is what the EPA intended.

Response to Comment 117: The final rule has removed the requirements for operating and fuel limits
with the exception of a PM CPMS.

Comment 118: Commenter 17775 states that under section 63.10010(h)(2)(ii)(D) there is a requirement
to "[pjerform checks at least once each boiler operating day to ensure pressure measurements are not

252


-------
obstructed (e.g., check for pressure tap pluggage daily)." According to the commenter, daily checks are
not warranted; pressure sensors are used in a variety of process functions (e.g., to monitor baghouse and
scrubber pressure drops, slurry tank liquid levels, etc.) and have design features that ensure the pressure
taps do not get plugged. The commenter states that for pressure sensors that are exposed to gases (e.g.,
boiler exhaust gases), the pressure taps have purge air to periodically clean them; the purges can be
varied to ensure that key pressure measurements are very reliable. For pressure sensors that are exposed
to liquids (e.g., scrubber slurry), states the commenter, redundant taps and a water cleaning system is
frequently used; while one tap is being cleaned with water, the other tap is being used for process
control. According to the commenter, while the EPA might believe it is reasonable to expect pluggage
problems with pressure taps, these types of problem rarely exist, and it would be unnecessarily
burdensome to expect technicians to check each pressure tap for pluggage every day.

Response to Comment 118: The final rule has removed the requirements for operating and fuel limits
with the exception of a PM CPMS.

19. ASTM methods.

Comment 119: Commenter 1775 states that the in addition to the use of ASTM D3173 for
determination of moisture content in fuel the EPA also should allow use of (1) ASTM D7582 "Standard
Test Methods for Proximate Analysis of Coal and Coke by Macro Thermogravimetric Analysis," or (2)
ASTM D5142 "Standard Test Methods for Proximate Analysis of the Analysis Sample of Coal and
Coke by Instrumental Procedures," which are equivalent to ASTM D3173, except that they are
automated. The EPA should reference ASTM D3302 "Standard Test Method for Total Moisture in
Coal," and ASTM D3180 "Standard Practice for Calculating Coal and Coke Analysis from As-
Determined to Different Basis." The commenter states that both ASTM D3302 and ASTM D3180 are
referenced in ASTM D3173, and in addition, the following methods are currently used by EGUs for Hg,
metals, and chlorine in coal and should be evaluated for inclusion without an equivalency analysis:

•	EPA Method 7473 - "Mercury in Solids and Solutions by Thermal Decomposition,
Amalgamation, and Atomic Absorption Spectrophotometry";

•	ASTM D4326 - "Standard Test Method for Major and Minor Elements in Coal and Coke Ash By
X-Ray Fluorescence";

•	ASTM D6357 - 04 - "Test Methods for Determination of Trace Elements in Coal, Coke, &
Combustion Residues from Coal Utilization Processes by Inductively Coupled Plasma Atomic
Emission, Inductively Coupled Plasma Mass, & Graphite Furnace Atomic Absorption
Spectrometry."

Finally, states the commenter, a number of methods that were identified in Table 2.3 of the 2010 ICR
are not included in the rule. According to the commenter, the EPA should include these methods or
explain why they were excluded.

Response to Comment 119: The final rule has removed the requirements for operating and fuel limits
with the exception of a PM CPMS. The only fuel-related provision in the final rule is an option for
liquid oil-fired units to demonstrate compliance with the acid gas standards by documenting that fuel
moisture content remains no greater than 1.0%. This demonstration is based on monitoring results or
fuel supplier certifications without reference to any specific methods for such analyses. As for the fuel
metals contat sampling and analysis, the rule no longer requires such measurement eliminating the need
to specify these methods.

253


-------
Comment 120: Commenter 17808 recommends the EPA set a percent water content limit for oil, rather
than setting HC1 and HF emissions limits for liquid oil-fired EGUs. The commenter states that ASTM
test methods are available for measuring the percent water content of fuel oil (D95 and D473) and that
plant operators would test each shipment received to ensure compliance with the proposed limit.

Response to Comment 120: The EPA agrees. The only fuel-related provision in the final rule is an
option for liquid oil-fired units to demonstrate compliance with the acid gas standards by documenting
that fuel moisture content remains no greater than 1.0%. This demonstration is based on monitoring
results or fuel supplier certifications.

20. Miscellaneous.

Comment 121: Commenter 18025 requests clarification with respect to demonstrating compliance
when using a new or changed blend of fuel that was not initially considered in compliance
demonstrations. The commenter's understanding is that any time a unit burns a new fuel (type, mix,
etc.), it has to be tested for relevant constituents (Hg, chlorine, etc.). The commenter states that if these
are within the parameters established during initial compliance testing, the fuel may be used, and if not
(for example, the chlorine is higher than established during initial testing), the unit must conduct new
testing to demonstrate compliance before using the new fuel. The commenter would like confirmation
that the proposed rule is flexible enough to accommodate shifts in fuel blends after 2015.

Response to Comment 121: The final rule has removed the requirements for operating and fuel limits
with the exception of a PM CPMS.

Comment 122: Commenter 17821 states that in some cases the only viable option is to utilize stack
testing. According to the commenter the use of total PM proposal using filterable PM as an operating
limit and PM CEMS as a compliance option is flawed; the viability of HC1 CEMS make this option
unrealistic; and sources using dry sorbent or have older FGD may not be capable of maintaining S02
emissions below 0.2 lb/MMBtu.

Response to Comment 122: The agency disagrees with the commenter's suggestion that the use of PM
CEMS as a compliance option is flawed. The final rule has been revised to use a filterable PM standard,
with a PM CPMS option available to monitor continued performance and compliance with an operating
limit established in terms of the raw output of the monitor. For sources unable to meet the SO2 standard
or use HC1 CEMS, the frequency of required testing has been changed to quarterly.

Comment 123: Commenter 17808 recommends the use of Hg as a surrogate for Se and, thus, filterable
PM alone may be a surrogate for other HAP metals. The commenter states that in the preamble, the EPA
states that selenium is captured by controls for Hg and acid gases. In fact, states the commenter,
commenter's initial correlation analysis indicates that selenium emissions are in fact better-correlated to
Hg and acid gas emissions than CPM (r=0.44 for Hg or 0.60 for HC1, versus 0.32 for condensable PM (r
> 0.2 implies significance at 5 percent level with 60 units)).

Response to Comment 123: The EPA has removed the requirement of total PM as an alternate
equivalent standard for HAP metals. For more detailed discussion and response, please see section
4F01A.

Comment 124: Commenter 17808 recommends PM CEMS combined with a separate Se standard. Se
emissions could be confirmed by quarterly or annual stack testing limited to Se. According to the

254


-------
commenter, similar to the treatment of limited use units, this requirement could be scaled such that units
emitting Se well below the standard were subject to less stringent monitoring requirements than those
units emitting very close to the standard. Alternatively, states the commenter, at a minimum, the
commenter recommends that the EPA base the filterable PM limit on the facility-specific ratio to the
total PM standard, rather than the initial numerical performance. Commenter also recommends that this
facility-specific limit remain constant for a longer period of time, such as annually, to provide a measure
of regulatory certainty.

Response to Comment 124: The final rule does not use a total PM standard as a surrogate for non-Hg
HAP metals, but instead uses a filterable PM limit. The PM CEMS monitoring will in fact be a
parameter monitor (PM CPMS) which is not intended to produce results in terms of the standard. These
changes address the concerns at issue in this comment.

Comment 125: Comment 18428 ask for clarification as to whether the purpose of operating limits is to
ensure compliance between performance tests.

Response to Comment 125: Yes. Operating limits are part of the compliance monitoring and assurance
provisions in the rule. In the final rule, the only operating limits that apply are for a PM CPMS and, in
certain situations, for liquid oil-fired units. See further discussion elsewhere in this document and in the
final preamble.

Comment 126: Commenter 17655 recommends clarification of section 63.10005 that allows
exemptions from the PM testing and testing for specific metals, but only for single fuels. According to
the commenter, the rule should be clarified to allow similar provisions for units that co-fire (e.g., coal
with natural gas). The commenter also notes that units testing for PM should not have to test for HAP
metals because there is no HAP metals limit. The commenter believes testing for metals is simply an
extension of the ICR.

Response to Comment 126: In response to comments, the final rule has removed all requirements for
duplicative testing of a HAP and an alternate equivalent standard. Facilities complying with an alternate
equivalent limit do not have to perform periodic testing for the corresponding HAP or vice versa.

Comment 127: Commenter 17655 encourages the EPA to consider opacity as an acceptable measure of
PM. Contrary to manufacturers' claims, the commenter does not regard stack-mounted PM monitors to
be sufficiently accurate, reliable, or durable to yield significantly more or better compliance data than
opacity monitoring currently does. The commenter notes that PM monitoring is a direct measurement of
PM, which is the limit for EGUs. The commenter states that although PM is itself a surrogate for non-
Hg metals, it is the primary standard expressed in the regulation - compliance with specific metals limits
would be regarded as an alternative compliance option rather than a primary option under this rule.
According to the commenter, the surrogate continuous monitoring method for PM emissions has always
been, and should continue to be, opacity measurement.

Response to Comment 127: The EPA disagrees that opacity would be considered accurate or sensitive
to the concentration levels of PM required by the final rule.

Comment 128: Commenter 17730 states that they appreciate the EPA setting the performance testing
requirements for all pollutants at the 5-year interval. The commenter believes that for sources that
choose to use CEMS to demonstrate ongoing compliance with the standards, the performance testing

255


-------
requirements could be even further streamlined given that sources will be required to report
electronically and that CEMS users will undergo annual certification via RATA.

Response to Comment 128: The final rule has been revised so sources electing to use CEMS for Hg,
SO2, or HC1 will not be required to perform performance testing every 5 years.

Comment 129: Commenter 17761 states that if PM CEMS are required, the commenter recommends
providing for an annual PM stack testing compliance alternative as the basis for determining compliance
with the limits established under this rule. According to the commenter, an annual PM stack test is
effective in determining compliance because operating units under existing CAM plans have prescribed
methods to verify PM to include bag leak detection and opacity readings.

Response to Comment 129: The final rule requires quarterly performance testing or PM CPMS with
annual performance testing.

Comment 130: Commenter 17775 states that the EPA's proposal contains nothing to indicate at what
point a monitoring system is deemed "certified" and if the EPA were to attempt to define that point,
sources likely would arbitrarily attempt to postpone some part of the required testing in order to control
when the "performance test" begins. According to the commenter, the EPA should allow EGUs to
complete required testing (or designate a CEMS that previously has completed the required testing") and
to notify the Administrator of the date upon which its "performance test" will begin. The commenter
states that this will ensure consistency between EGUs and allow EGUs to confirm that their controls are
working properly, and that they are operating at an appropriate load and combusting appropriate fuel,
before the "performance test" begins.

Response to Comment 130: That approach is allowed for under the final rule. The notification of intent
will indicate the date for commencement of a performance test.

Comment 131: Commenter 17886 states that the EPA should not set unit "operating limits" based on
performance measured during short term tests. According to the commenter, if the EPA retains the total
PM requirement, one preferable option would be to ratio the performance test results to the MACT limit,
and set the "operating limit" at the level that (based on the test results) would be equal to the MACT
limit.

Response to Comment 131: The final rule does not maintain the total PM requirement.

Comment 132: Commenter 19120 requests clarification as to whether the EPA intends to require 1/5
year stack testing for all surrogates. For example, states the commenter, section 63.100005(d)(4) states
that initial compliance for coal-fired EGUs with FGD technology using S02 CEMs is determined using
the average hourly SO2 concentrations obtained during the first 30-day operating period, and section
63.10005(d)(5) states the same for PM CEMS. However, notes the commenter, pages 423 and 425 of the
preamble and section 63.1 0005(a) indicate that PM and metals and SO2 and HC1 testing includes testing
initially and every 5 years; section 63.10005(a) states that "If you use a continuous monitoring system
that measures a surrogate for a pollutant (e.g., an SO2 monitor), you must perform initial emission
testing during the same compliance test period and under the same process (e.g., fuel) and control device
operating condition of the pollutant and surrogate, in addition to conducting the initial 30-day
performance test." Additionally, states the commenter, section 63.10006(a) and (b) state, that PM and
non-Hg metal HAP, and SO2 and HC1 emissions testing, respectively, is required at least every 5 years.

256


-------
Response to Comment 132: In response to comments, the final rule has removed all requirements for
testing of both the HAP and the corresponding surrogate(s). Facilities complying with a surrogate limit
do not have to perform periodic testing for the corresponding HAP or vice versa.

Comment 133: Commenter 17785 states that the proposed rule requires fuel analysis monthly in order
to assess continuous compliance. The commenter states that the portion of the draft rule that addresses
this (section 63.10011) is unclear. According to the commenter, equation 13 of this section seems to
suggest that the Hg concentration in a monthly sample must be less than the 90th percentile
concentration based on the Hg content measured during demonstration of initial compliance; equation
13 refers to the 90th percentile of Hg concentration as calculated according to Equation 8, but the
referenced Equation 8 calculates the average fuel Hg content, not the 90th percentile. The commenter
states that the EPA needs to clarify these equations so it is clear how they intend the 90th percentile Hg
concentration to be calculated.

Response to Comment 133: The fuel sampling and analysis requirements have been removed from the
final rule.

Comment 134: Commenter 17696 states that if the EPA does not limit the rule to Hg, the EPA should
provide additional flexibility in the emissions monitoring and compliance determination requirements.
Commenter believes certain of the proposed requirements are unreasonable in light of available
alternatives that are more cost-effective and provide sufficient assurance of continuous compliance. The
commenter states that revisions are also needed concerning Hg monitoring and to make the compliance
determination requirements clearer and easier to understand.

Response to Comment 134: The EPA believes that the final rule streamlines the continuous compliance
monitoring requirements, and does so in a way that is clearer and easier to understand as requested by
the commenter. The EPA disagrees with limiting the rule to Hg as explained in response to other
comments concerning this issue.

257


-------
5B01 - Recordkeeping/Reporting: Data reporting requirements
Commenters: 17402, 17655, 17677, 17681, 17772, 17821, 17881, 17902, 18023
1. Reporting requirements for deviations.

Comment 1: Commenter 17402 opposes the EPA's proposed definition of "deviation" and the EPA's
reporting requirements for deviations. The commenter states that in the proposed rule, the EPA defines
"deviation" to include (but the definition is not limited to) any failure to meet "any emission limit,
operating limit, work practice standard, or monitoring requirement," or any failure to meet a term or
condition to implement a related requirement included in an operating permit. The commenter states that
should a deviation occur, the EPA proposes specific reporting requirements, that in the case of an
exceedance of an emission limit during a malfunction, the owner or operator of the facility must notify
the EPA within two business days to avail itself of an affirmative defense to civil penalties for the
malfunction and submit a report of the malfunction within 45 days, and that all deviations must also be
reported in the source's semiannual compliance report.

Comment 2: Commenters 17402 and 17902 state the EPA's proposed definition of "deviation" is
overbroad and should not include operating limits. Commenter 17902 suggests that on-site records be
maintained that document operating limit deviations, associated investigation and appropriate corrective
action if deemed necessary. Commenter 17402 recommends that operating limits and monitoring
requirements should not be a reportable deviation since they are indicators of compliance and not
emission limitations. As an example, the commenter states that the EPA's proposal requires that for an
ESP, the parameter operating limit is calculated by the total secondary power input as measured during
the performance test. Commenter respectfully submits that operating parameter exceedances, such as
this ESP power limitation or CEMS downtime (failed calibration error test, power outages, data
acquisition and handling problems, etc.), are compliance indicators and, therefore, inappropriately
categorized as deviations.

Comment 3: Commenter 17402 states a further reason to exclude operating limits from the definition of
deviation is that these parameter operating limits do not account for variability due to normal operation
in some cases. As an example, the commenter states that the requirement of a minimum pressure drop
and liquid injection rate on a wet PM scrubber will result in the reporting of deviations during low-load
operation. Similarly, according to the commenter, the requirement to maintain sorbent injection rate at
the rate established during the compliance test might result in the unnecessary reporting of deviations
when these units fire lower pollutant containing fuels. The commenter asserts that since these
parameters do not take into account variability, it would be arbitrary and inefficient to characterize any
exceedance of the operating limit (or failure to meet the operating limit in the case of a minimum
operating limit) as a deviation.

Comment 4: Commenter 17402 further urges the EPA to reconsider its proposed reporting requirements
for deviations. Specifically, commenter opposes the EPA's proposal to require the owner or operator of
the facility to notify the EPA of an exceedance of an emission limit during a malfunction within two
business days to avail itself of an affirmative defense to civil penalties for the malfunction. Commenter
submits that such a requirement is excessive and recommends that if the EPA requires a notification for
exceedances of an emission limit during malfunctions, it should be in semiannual compliance reports.

Comment 5: Commenter 17881 states that in regard to requirements for reporting monitor downtime
deviations in section 63.10031(e)(5), the commenter asks that the rule needs to specify how the

258


-------
calculations for these deviations should be conducted. The commenter notes that calculations could be
based on the number of block averages in the reporting period, total operating time during the block
period associated with the deviation, etc.

Response to Comments 1-5: The EPA believes the rule was accurate as proposed in delineating what
is a deviation. Under most MACT standards, a deviation includes any failure to meet an emission limit,
work practice requirement, operating limit, or monitoring requirement. The final rule does not alter this
approach. Deviations are reported in semiannual compliance reports. The compliance reports require the
information in the General Provisions 63.10(e) section and some additional source specific information
which is typical of reporting. In addition, for malfunctions, additional notification requirements apply.
The EPA is revising the affirmative defense related malfunction notification requirement so that it reads
"The owner or operator of the affected source experiencing an exceedance of its emission limit(s) during
a malfunction shall notify the Administrator by telephone or facsimile (FAX) transmission as soon as
possible, but no later than two business days after the initial occurrence of the malfunction or, if it is not
possible to determine within two business days whether the malfunction caused or contributed to an
exceedance, no later than two business days after the owner or operator knew or should have known that
the malfunction caused or contributed to an exceedance, but, in no event later than two business days
after the end of the averaging period, if it wishes to avail itself of an affirmative defense to civil
penalties for that malfunction."

2. Reporting requirements for malfunctions.

Comment 6: Commenter 17681 states that section 63.1000 l(iii)(9) of the proposal appears to require
notification to the EPA Administrator of a malfunction within two business days of the event if the
malfunction may cause an exceedance of the 30-day average. According to the commenter, facilities
may not be aware that the malfunction will cause an exceedance of the 30-day average until more than
two days have passed. The commenter states that the reporting time should be at least as long as the
averaging time, which in this case is 30 days. In addition, the commenter questions whether facilities
may report to their local compliance office if the state is delegated under the CAA instead of reporting to
the EPA Administrator.

Commenter 17681 states this section (63.1000l(iii)(9)) also requires a calculation of emissions during
the malfunction. The commenter questions whether this calculation has to be prepared and sealed by a
professional engineer.

Response to Comment 6: The EPA is revising the affirmative defense related malfunction notification
requirement so that it reads "The owner or operator of the affected source experiencing an exceedance of
its emission limit(s) during a malfunction shall notify the Administrator by telephone or facsimile (FAX)
transmission as soon as possible, but no later than two business days after the initial occurrence of the
malfunction or, if it is not possible to determine within two business days whether the malfunction
caused or contributed to an exceedance, no later than two business days after the owner or operator
knew or should have known that the malfunction caused or contributed to an exceedance, but, in no
event later than two business days after the end of the averaging period, if it wishes to avail itself of an
affirmative defense to civil penalties for that malfunction." With respect to reporting to delegated state
agencies, that would occur in accordance with delegation of this subpart, if applicable. With respect to
preparation and signature by a professional engineer, the answer is no. The rule plainly states: "The
analysis shall also specify, using best monitoring methods and engineering judgment, the amount of
excess emissions that were the result of the malfunction."

259


-------
3. Quarterly reporting of hourly data.

Comment 7: Commenter 18023 believes the quarterly submittal of electronic hourly data is
inappropriate for an emission limit-oriented rule, is highly burdensome on the emission source operator,
and should be removed from the proposed rule requirements. Commenter states that section 7.2.5,
Quarterly Reports, is written to reflect the quarterly submittal of electronic hourly data that is
appropriate for a trading program-related rule, most likely because these requirements were copied out
of the vacated CAMR rule.

Comment 8: Commenter 17655 agrees that hourly data records are unnecessary for demonstrating
compliance. Commenter states that in evaluating the cost of hourly reporting, the EPA consulted with
DAHS vendors and was told that the cost of collecting hourly data would be minimal. However,
commenter believes the agency failed to consult with users to ascertain the time requirements and costs
for reviewing hourly data, as opposed to records compressed to daily, weekly, or even monthly
averages. Commenter submits that there is no need for hourly data, as there are no hourly compliance
standards. Further, ECMPS could be easily adapted by the EPA to accommodate records in other than
hourly increments (daily or monthly). According to the commenter, this would provide considerable
savings to the industry and would not impact compliance or public health in any way.

Comment 9: Commenter 17772 states that the EPA should modify the requirements for submitting
extensive new continuous data sets for compliance purposes. According to the commenter, the approach
taken in the proposed rule may be appropriate for an allowance trading program where there is a market
function that is facilitated by the collection and public posting of emissions data. The commenter asserts
that that approach is unnecessary and unduly burdensome in the context of a regulatory regime where
the focus is on demonstrating technology compliance.

Commenter 17772 states that in an age of electronic recordkeeping, there is a natural tendency to ask for
"all the data that is available." According to the commenter, however, in industrial America and in the
utility sector, routine reporting of massive amounts of hourly data to the EPA is an unwarranted use of
manpower for both the transmitters and recipients, not to mention bandwidth and storage considerations.

Commenter 17772 states that the industry has grown accustomed to electronic data reporting in S02 and
NOx trading programs. According to the commenter, in such a program, where there is a national market
in allowances, a case can be made for submitting hourly data on a quarterly basis so that it can be posted
on a national website. The commenter states that this creates a transparent database for economic
decisions and trading.

Commenter 17772 states that demonstrating that a facility has installed MACT level controls and is
operating that equipment appropriately is an entirely different type of regulatory approach and the
reporting requirements should be consistent with that regulatory approach. The commenter requests that
the EPA modify its approach as follows: (1) The related limits will be specified in the Title V permit. (2)
The responsible entity is required to certify each year as to full compliance or intermittent compliance.
(3) Records should be kept and made available as necessary to the EPA. (4) Exception reporting should
be performed quarterly.

Commenter 17772 states that this recommendation is a proven approach used by the EPA for other
industries and in other contexts and there is no need for EGU compliant facilities to transmit massive
MACT-related databases to the EPA every quarter.

260


-------
Commenter 17772 states that this proposal is consistent with past EPA MACT requirements imposed on
other industries. According to the commenter, for example, the MACT program applied to the steel
industry does not require multiple CEMS and quarterly reporting of all hourly data; that would be
unwarranted and unwieldy. The commenter states that the same can be said about the pulp and paper
industries, etc., and that the utility sector should be treated similarly - exception reporting, but not
massive transfers of compliant hourly data. According to the commenter, it is arbitrary and capricious to
single out the utility industry for a level of MACT reporting that is far in excess of other important U.S.
industries.

Response to Comments 7-9: The EPA has retained in the final rule that CEMS data be provided on an
hourly basis. We believe this approach simplifies compliance with the rule by harmonizing its
monitoring and reporting requirements, to the extent possible, with those of 40 CFR Part 75. With a few
exceptions, the utility industry is already required to monitor and report hourly emissions data according
to Part 75 under the title IV ARP and other emissions trading programs. The Hg monitoring
requirements are consistent with Part 75 and similar to those that had been promulgated for the vacated
CAMR regulation. Integrating Hg emissions data and QA test results into the existing Part 75 -
compliant DAHS that is installed at the vast majority of the coal-fired EGUs is an appropriate approach
for addressing submission of emissions and QA data under this rule. We obtained feedback from several
DAHS vendors indicating that the cost of modifying the existing Part 75 DAHS systems to
accommodate hourly reporting of Hg CEMS and sorbent trap data would be similar, and in some cases,
less than the cost of the first proposed option. Also, there is little or no cost to industry for the flow rate,
CO2, or O2, and moisture monitors needed to convert Hg concentration to the units of the standard,
because, as previously noted, almost all of the EGUs already have these monitors and the associated
reporting mechanisms in place. In view of these considerations, we have decided in favor of this second
option for Hg.

Requiring the reporting of hourly Hg emissions data from EGUs is advantageous, both to the EPA and
industry. The DAHS can be automated to demonstrate compliance with the standard on a continuous
basis. The data can then be submitted to the agency electronically, thereby eliminating the need for the
agency to request additional information for compliance determinations and program implementation.
The rule also requires quarterly electronic reporting of hourly S02 CEMS data and HC1 CEMS data (for
sources electing to demonstrate continuous compliance using those certified CEMS). Those are included
for the same reasons as the Hg monitoring data.

The comments seem to assume that the costs for adding new parameters to the system would be directly
proportional to the number of parameters collected. This neglects to recognize that the ECMPS and
DAHS frameworks do not need to be re-engineered if the new data requirements are adopted in a
manner that harmonizes requirements. Also, reducing the computer output to daily or monthly values
does not necessarily save the user any significant (if any) effort. In fact, it may cost the source more
effort or cause them to miss data problems that in the end may affect their compliance determination.
Once data collection is automated (and given that the industry and the EPA has already invested in the
automation process that is ECMPS) the burden on the operator is minimized. The systems can (and
have) been programmed to do data analysis and QA evaluations automatically, giving a user a report of
hours that might be in question. The environmental managers at facilities can, and have, designed
custom checks into their systems to streamline their data reporting responsibilities. These advantages
need to be recognized when evaluating the electronic reporting option as a means for data QA.

4. Recordkeeping requirements for liquid oil-fired units.

261


-------
Comment 10: Commenter 18023 states that the recordkeeping requirements for liquid oil-fired units are
unreasonable. The commenter states that the EPA requires "for each 30 boiler operating day period ... a
description of the fuel, the total fuel usage amounts and units of measure, and information on the
supplier and original source of the fuel" (76 FR 25035). According to the commenter, other than total
usage amounts, these records are, and should be, kept by shipment and if all shipments are in
compliance, additional information is unnecessary. The commenter asserts that it is not possible to
collect this information in the format requested by the EPA - fuel cannot be separated on a per-shipper
basis after it has been put into a storage tank - but only by shipment and that to avoid the burden of
having to convert shipment-based data into operating-day data, the EPA should base any recordkeeping
requirement on shipment data.

Response to Comment 10: With the changes in the final rule that eliminate the fuel analysis
requirements, this comment is largely moot. The only fuel data that must be retained is a record of fuel
use by operating hour, in order to determine if the EGU meets the low use exemption. Also, if a source
opts to monitor fuel moisture in each fuel shipment for a liquid fuel unit and demonstrates that this
alternative monitoring is acceptable under the part 63 general provisions (in lieu of other monitoring for
acid gases), then the source must keep records of the fuel moisture of each fuel shipment.

5.	Semi-annual compliance dates.

Comment 11: Commenter 17681 states that section 63.10031(b)(2) of the proposed rule appears to
require semi-annual reports on January 31 and July 31 and that the beginning of the year is very busy
with reports required to state and federal agencies. The commenter states that the EPA should push these
dates back to March 1 and September 1 respectively. For the same reasons, commenter 17821 requests
that the EPA should allow sources at least 60 days to submit reports, and the EPA should allow local
permitting agencies the flexibility to grant sources 60 days to file their semi-annual reports.

Response to Comment 11: The semiannual compliance dates are consistent with other EPA reporting
requirements and are necessary to ensure timely reporting and allow any identified issues to be
addressed in a timely manner. These dates do not apply to the quarterly reporting to ECMPS of CEMS
data.

6.	Annual documentation.

Comment 12: Commenter 17677 states that the regulation includes documentation for an annual report
on emission tests, inspection, repairs, adjustments, findings and corrective actions. Commenter believes
this additional documentation burden seems to do nothing more than increase non-productive work load
for our personnel.

Comment 13: Commenter 17681 also notes that section 63.10031(c)(5) of the proposed rule appears to
require a summary of the annual performance tests in the compliance report which is submitted to the
EPA. If the testing data is reported electronically to the EPA within 60 days after each test through
CDX, why does the EPA need this data sent to them again?

Response to Comments 12-13: The final rule contains compliance and deviation reporting
requirements that are typical of most NESHAP. These summary reports are in addition to the detailed
performance test results reported electronically and will be used by the permitting authority for effective
compliance oversight.

262


-------
7. Other data reporting requirements.

Comment 14: Commenter 17881 states that the requirement in section 63.10031(c)(4) to report monthly
fuel use is not relevant, as it is the fuel type and heat input fraction that matters in determining
compliance. The commenter suggests that the section 63.10032(d)(1) requirement to maintain such
records should be deleted, or at a minimum, revised to require records of the types of fuel which are
burned and the maximum percentage or fraction of each fuel type (on a heat input basis).

Comment 15: Commenter 17881 states that the waste determination information should only be
required if a new fuel type is introduced following the initial compliance demonstration report.

Response to Comments 14-15: Apart from those EGU owners or operators who choose to use
emissions averaging, monthly fuel use information need not be reported given the changes in the final
rule, although records of fuel use by operating hour must be maintained, as noted above. Moreover,
EGU owners or operators who self-determine or have the EPA determine via petition that their fuel is a
non-waste under 40 CFR 241.3 or who combust fuel processed from discarded non-hazardous secondary
materials have additional emissions testing, notification, reporting, and recordkeeping requirements as
discussed in the rule.

263


-------
5B02 - Recordkeeping/Reporting: Records that must be retained
Commenters: 17681, 17775, 17881

1.	Objection to retaining records on-site.

Comment 1: Commenter 17681 states that section 63.10033(c) of the proposed rule appears to require
that records be kept on site. Commenter believes it is much better to keep records electronically or at
least not congregated at each site and if the EPA wants a copy, the facility can produce a copy within a
reasonable time.

2.	Objection to requirement to retain records for five years.

Comment 2: Commenter 17775 states that the EPA proposes to require retention of all data, including
reports, records of measurements, maintenance, corrective action, and "other information," for 5 years.
(Proposed section 63.10033 and Appendix A section 7.1.) Commenter objects to these requirements. To
mandate a retention period longer than 3 years, the EPA must justify the requirement under the PRA.
See 5 CFR section 1320.5(d)(2)(iv) (requiring a showing of substantial need or statutory mandate to
require retention of records for more than 3 years). The commenter states that the EPA's statement in the
supporting statement for the February 2011 proposed ICR291 that "None of the guidelines in 5 CFR
1320.5 are being exceeded," is simply false. The EPA-HQ-OAR-2009-0234-3031 at 4.

Response to Comments 1-2: The agency believes the record keeping and retention requirements are
consistent with other requirements already in place, specifically 40 CFR part 63.10 (b) "General
recordkeeping requirements. (1) The owner or operator of an affected source subject to the provisions of
this part shall maintain files of all information (including all reports and notifications) required by this
part recorded in a form suitable and readily available for expeditious inspection and review. The files
shall be retained for at least 5 years following the date of each occurrence, measurement, maintenance,
corrective action, report, or record. At a minimum, the most recent 2 years of data shall be retained on
site. The remaining 3 years of data may be retained off site. Such files may be maintained on microfilm,
on a computer, on computer floppy disks, on magnetic tape disks, or on microfiche." In addition, the 5-
year retention period is the general rule for all recordkeeping for all sources under the part 70 operating
permits program. Given that the general provisions for part 63 and part 70 already establish a 5-year
retention period, the EPA believes it is justified in using those precedents for the retention periods under
this subpart. If the EPA stayed silent on retention period in this subpart, the general provisions would
provide for the 5-year retention as would the part 70 requirements. Thus, this action does not establish
any new retention requirements, but merely confirms that the existing retention requirements apply.

3.	Objection to requirement to maintain mercury mass emission records.

Comment 3: Commenter 17881 states that section 7.1.8 requires Hg mass emission records for those
units complying with the Hg lb/GWh emission limit. According to the commenter, this section is based
on the misguided premise that the Hg mass emissions, as pounds per clock hour, are required in order to
perform the lb/GWh Hg emission rate calculations. The commenter states that as noted in relation to
section 6.2.2, only the Hg emission rates, as lb/hr, and average electrical generating rate, as MW, are
needed in order to calculate the lb/GWh emission rate. Thus, according to the commenter, this section
should be re-written on a Hg mass emission rate versus integrated mass emissions basis.

264


-------
Response to Comment 3: The EPA has retained the language as is, given the formulas that are used
determining lb/GWh.

265


-------
5B03 - Recordkeeping/Reporting: Electronic reporting of CEMS data

Commenters: 17715, 17716, 17725, 17730, 17740, 17775, 17795, 17796, 17800, 17805, 17820, 17821,
17873, 17877, 17886, 17909, 18014, 18039, 18449, 18498, 18831, 19114, 19121, 19122, 19679

1. ECMPS reporting.

a.	Support for ECMPS reporting.

Comment 1: Commenters (17715, 17740, 17796, 17805, 17877, 17909, 18039, 18449, 19122) support
using ECMPS.

Comment 2: Commenter 17796 believes all CEMS collected data should be required to be submitted to
a modified ECMPS so this data can be assembled in one area which can be accessed by all users.

Comment 3: Commenters 17805 and 19122 also agree that ECMPS could be used for submittal of
compliance data as required in the proposed rule. The commenters note that his system is currently used
successfully to report Acid Rain Program emissions from utility units.

Comment 4: Several commenters (17740, 17873, 18039, 18449, 18831) support the EPA's proposal to
handle reporting for PM, HC1, and Hg through ECMPS. According to the commenters, the ECMPS
system simplifies the reporting process by evaluating continuous monitoring data and other information
in an electronic format in preparation for submittal to the agency. The commenters note that ECMPS is
used by Part 75 and emissions trading programs and is a well-established data reporting tool.

Comment 5: Several commenters (17715, 17877, 19114) state that ECMPS is currently being used
successfully by industry and the infrastructure is already in place, thereby reducing costs. According to
the commenters, industry personnel have been trained for the constituents that are already being reported
by ECMPS so the learning curve will be very short and will allow a rather seamless transition to HAP
reporting. One commenter proposes that the EPA take advantage of the work that has already been done
for the ECMPS process by extending it to the HAP rule.

Comment 6: Commenter 19121 recommends that ongoing monitoring data collected under the
requirements of NESHAP be reported into the ECMPS system. Commenter recommends that episodic
data, such as performance and stack testing be reported using the ERT.

b.	Support for ECMPS reporting, but with supplemental rulemaking and public comment.

Comment 7: Commenters 17715 and 19114 state that the EPA should use ECMPS for all reporting.
Commenters state that reporting associated with the proposed rule should be handled by ECMPS, but
should be the subject of a supplemental rulemaking in order to fully address all of the software issues
that arise with electronic reporting. According to the commenters, the EPA should invite industry
involvement as was used during the initial development process of ECMPS. The commenters note that
utility involvement during development will enable a smooth transition in dealing with the numerous
monitoring requirements that will impact every EGU stack at the same time.

Comment 8: Commenter 17730 supports the use of ECMPS for the reporting of data and summary
reports as a part of the EGU MACT proposed rule but believes that if the EPA wants to require the use
of ECMPS, the EPA will need to publish for public comment (1) additional reporting provisions to

266


-------
cover information to be reported for SO2 CEMS, PM CEMS, HC1 CEMS, and any other test or
parameter the EPA intends to include; and (2) its reporting formats and instructions for all data to be
reported. Commenter states that the EPA has not published reporting requirements in sufficient detail for
any parameter other than Hg. According to the commenter, although the EPA previously developed a
reporting format for Hg, that format was developed to meet reporting requirements under the now-
vacated CAMR. Commenter states that the EPA cannot use a reporting format to specify substantive
reporting requirements but that the rule must identify each piece of information to be reported.
Commenter adds that the EPA must submit its desired format and instructions to an open public
comment process so that the regulated community and members of the public can confirm that the EPA
is not attempting to use the format to create new, or alter existing reporting requirements.

Comment 9: Commenter 17800 states that should the EPA require use of ECMPS, the EPA would at a
minimum need to publish for comment (1) additional reporting provisions to cover information to be
reported for SO2 CEMS, PM CEMS, HCL CEMS and any other test or parameter the EPA intends to
include, and (2) its reporting formats and instructions for all data to be reported.

Comment 10: Commenters 17775 and 17800 in disagreeing with the reporting format requirements in
Appendix A, note that the EPA is obliged to subject that format to notice and comment rulemaking and
review by OMB. According to the commenters, the EPA electronic reporting formats specified to date
by the Administrator have been sufficiently complex and substantive that it is not appropriate to totally
exempt them from rulemaking. The commenters state that as implemented, the EPA's electronic formats
are substantive requirements that impose significant burdens and impact on EGU's compliance status.
The commenters state that to the extent some flexibility is needed to make adjustments to the format,
that flexibility can be provided by rule.

Comment 11: Commenter 19114 recommends that the EPA invite industry involvement as was used
during the initial development process of ECMPS, to enable a smooth transition in dealing with the
numerous monitoring requirements that will impact every coal- or oil-fired EGU stack as a result of the
EGU-MACT proposal. According to the commenter, the EPA should develop the tool, then propose its
use in a separate rulemaking. The commenter states that numerous times industry has been stuck with
software implementations that are not ready and that issues with software should be handled in advance
of it being required for compliance with a rulemaking.

c. Opposition to ECMPS reporting.

Comment 12: Multiple commenters (17716, 17725, 17795, 17820, 17821, 17886, 18014, 18498) state
that reporting hourly CEMS data electronically should not be required. The commenters state that the
EPA proposes to require quarterly reporting of hourly emissions data as well as results of all required
certifications and QA tests through the CAMD ECMPS software and that summaries of the emissions
test results and semiannual deviation reports would also be required for S02 CEMS, PM CEMS, and
HC1 CEMS. The commenters believe there is no need for this requirement; the hardcopy deviation
reports and data assessment reports are adequate and consistent with the requirements of other MACT
and NSPS compliance rules.

Comment 13: Multiple commenters (17716, 17725, 17775, 17795, 17820, 18014, 18498) state the EPA
has not justified the burden of requiring the ECMPS reporting. Several commenters (17716, 17725,
17775, 17820, 18014, 18498) state that the data reporting requirements in Appendix A for Hg go far
beyond what is necessary for this rule. The commenters state that the EPA portrays this proposed
reporting requirement as easy - that sources would "simply integrate Hg emissions data and QA test

267


-------
results into the existing Part 75-compliant DAHS," under one of two options. One commenter states that
after presenting these two options, the EPA states that it obtained "feedback from several DAHS
vendors" who suggested the cost of the second option was "similar, and some cases, less than the cost of
the first option." According to the commenter, any software under Option 2 would have to provide the
same information required by Option 1; The commenter states that sources would likely integrate the
new requirements within the DAHS that they currently use for Part 60 and Part 75 reporting, but this
does not mean that the proposed reporting scheme would be simple or cheap to implement. According to
the commenters, adding the requirement to report hourly emissions data and other QA/QC data would be
burdensome both to utilities as well as the EPA, especially given differences between Part 75 and
MACT reporting (such as bias adjustment factors and missing data substitution). The commenters assert
that CMPS was developed for emissions trading purposes, not for demonstrating continuous compliance
with emission limits. The commenters conclude that reporting information via ECMPS under this rule
would be a costly exercise that is both unnecessary and unjustified.

Commenter 19679 asks for clarification on whether the Hg CEMS data to be integrated into the Part 75
compliance DAHS will be subject to the on-going QA requirement of Part 75 or if it would be subject to
the QA requirements of Part 60 Appendix F and PS-12A as is indicated for the "first option". According
to the commenter, specifically relevant to this distinction is the requirement listed in Part 75, appendix A
section 7.6.5 to apply a bias adjustment factor to CEMS data as part of a RATA. The commenter states
that due to the low Hg concentrations present in a well controlled coal fired utility boiler stack, without
the requirement for a bias adjustment factor the low emitter exemption of Part 60, PS-12A section 13.3
could allow a Hg CEMS to pass the required RATA while under reporting emissions relative to the
emission standard.

Comment 14: Commenters 17775 and 17795 object to the EPA's proposal to submit hourly Hg data.
Commenter 17775 states that the EPA has not justified or prepared an ICR for the proposed
requirements for quarterly reporting of hourly Hg emissions data. The commenter disagrees with the
EPA's assumptions regarding hourly Hg data and QA reporting.

Comment 15: Commenter 17775 states that the EPA could develop an electronic reporting scheme as
an alternative to ECMPS or ERT that might more easily accommodate the kinds of information the EPA
seeks to collect. According to the commenter, whatever scheme the EPA uses, it still would need to be
supported by a rule, and new ICR, that identifies each piece of information to be reported and a format
that has been subject to review and comment. The commenter notes that the supporting statement for the
February 2011 proposed ICR for the proposed rule does not mention reporting of hourly Hg emissions
data, or of the QA and certification data for Hg monitoring systems. The commenter states that the
proposed ICR also makes no mention of the EPA's development and maintenance of schema and
software for collection or review of those data, or an accounting of their costs. According to the
commenter, if the EPA were to move forward with a requirement to report other information using
ECMPS, the EPA would need to issue a rulemaking proposal and ICR that identifies (similar to
Appendix A) each piece of information required to be reported, and the specific format for that
submission and would need to provide a justification for requiring reporting of that information.

Commenter 17775 objects to the EPA's proposal to submit hourly Hg data. The commenter states that
the EPA has not justified or prepared an ICR for the proposed requirements for quarterly reporting of
hourly Hg emissions data.

268


-------
Commenter 17775 states that Part 75 reporting is unsuitable for the reporting proposed under Appendix
A and the revisions required to the EPA's and EGU's software to implement the reporting proposed
under Appendix A would be significant and costly.

Commenter 17775 states that in addition to the compliance report, deviation report, performance tests
and monitoring system performance evaluations, the EPA proposes to require quarterly reporting of
hourly Hg data (e.g., emissions, certification and QA, and monitoring plan data) using the EPA's
ECMPS. According to the commenter, although the proposed rule does not mention ECMPS, Appendix
A includes detailed recordkeeping requirements similar to what had been included in CAMR, and
requires quarterly electronic reporting of much of that information "in a format specified by the
Administrator." Commenter 17775 states that all of the information needed to determine an EGU's
compliance status already must be reported under the part 63 general provisions. The commenter finds
these additional requirements to be redundant and burdensome. If the EPA requires additional detail, the
EPA should provide that additional detail in proposed section 63.10031 and, if the provisions overlap,
make clear that the more detailed requirements are in lieu of the more general requirements.

Commenter 17775 states that in the EPA's discussion of modifications to ECMPS, the EPA suggests
that ECMPS also could be modified to allow electronic submission of "30-day averages of parametric
data, 30-day average fuel content data, stack test results, and performance of tune up records." The
commenter notes that the EPA's proposed rule does not contain any requirements to record, let alone
report, 30-day averages of parameter and fuel data.

Commenter 17886 states that the EPA needs to define what constitutes a valid 30-day rolling average,
suggesting that the EPA should use a specific number of hours (i.e., 540 hrs or 75 percent of the month)
in that period to qualify it for a valid period.

Commenter 17775 disagrees with the EPA's proposal for data reporting in Appendix A. The commenter
observes that the EPA has not required hourly data reporting or the sorts of QA data identified in
Appendix A in a MACT, and this information is not necessary for sources or the EPA to determine
compliance with MACT standards. The commenter states that this information does not enhance the
quality of MACT compliance demonstrations.

Commenter 17775 objects to the EPA's requirement in Appendix A to require submission of Hg
monitoring information in quarterly reports to the Administrator "in a format specified by the
Administrator." The commenter notes that the commenter has challenged similar provisions for use in
other programs judicially. The commenter's objections are: (1) concerns regarding the nature and
content of the EPA's format, which the agency has changed with some frequency and at significant
expense to EGUs, (2) the EPA-provided software's failure to ensure compliance with the CROMERR
requirements at 40 CFR part 3.10, (3) inconsistencies between the reporting format and the substantive
provisions of the applicable rule, and (4) the lack of appropriate procedures for submitting reports when
a source is unable to gain access to the EPA's computer with the EPA provided software, or connect to
the internet in a secure environment.

Comment 16: Commenter 17909 does not support collection of continuous Hg or particulate data.
According to the commenter, the EPA's authority under this section of the CAA is for exception
reporting only.

2. Data reporting formats.

269


-------
Comment 17: Commenter 17725 asks that the EPA consider a single format for reporting data. The
commenter states that for each set of monitoring and reporting requirements, reporting entities must
purchase monitors and data acquisition handling systems. According to the commenter, these systems
must be connected to other plant data monitoring systems and integrated into a single report. The
quantity of data for EGUs can be staggering. The commenter encourages the EPA to employ like data
collection and transfer systems for multiple programs so that this expensive system can be used for each
program, especially since much of the data is the same. The commenter states that the utility industry
has worked with the CAMD for the last 17 years to devise a comprehensive schema that is flexible and
is relatively easy to maintain. The commenter recommends that this program and others continue to use
ECMPS or devise a way to import data between programs.

Commenter 17725 suggests that the EPA use ECMPS reporting for the following data elements:

1.	Monitoring Plan Data for PM CEMS, HC1/HF CEMS, Continuous Hg Monitoring Systems, and
Sorbent Trap Monitoring Systems similar to what is currently being collected for COMS.

2.	Monitoring Plan Data for Auxiliary Boilers present at facilities currently reporting in ECMPS
required under the Industrial Boiler MACT rules.

3.	Certification Test Results for PM CEMS:

a.	PS-11 Initial Correlation Audit Results

b.	PS-11 Absolute Correlation Audit Results

c.	PS-11 Annual Relative Response Audit Results

d.	PS-11 Response Correlation Audit Results

e.	Initial Certification 7-Day Drift Test Results

4.	Certification Results for Continuous Hg Monitoring Systems:

a.	Initial Certification Cycle/Response Time, 7-Day Drift, 3-point Linearity Check, and RATA
test results

b.	NIST Traceability Test Results

c.	Annual RATA testing results

d.	Weekly System Integrity Check results

5.	Certification Results for Sorbent Trap Monitoring Systems:

a. Initial and Annual RATA test results

6.	Certification Results for HC1/HF CEMS:

a.	Initial Certification Cycle/Response Time, 7-Day Drift, 3-point Linearity Check, and RATA
test results

b.	Required ongoing quarterly and annual ongoing QA Tests for HC1/HF CEMS

Commenter 17725 does not support routine hard copy submittals of Monitoring Plan records as listed in
Appendix A to subpart UUUUU section 7.1.1.2.2 and wishes to maintain an onsite file at each facility
that can be made available for inspection by the EPA and state auditors and inspectors.

Response to Comments 1-17: We recognize that emissions reporting for continuously measured
pollutants (SO2, Hg, etc.) and for periodically measured pollutants (PM, non-Hg HAP metals, etc.) have
different data demands. We recognize that minor revisions of the ECMPS will fulfill our data needs for
continuously measured pollutants and we will make these minor modifications for receipt of the

270


-------
additional data demands. We also recognize the need for substantial modifications to the ECMPS to
accommodate the data needs for periodically measured pollutants. Although major modifications of the
ECMPS would be required for periodic compliance tests by isokinetic and instrumental test methods,
minor revisions are required of the ERT to receive these tests. We are implementing the changes in the
ERT that are required to provide the software tools to implement the delivery of these performance test
data to us.

The electronic submission of compliance test reports to us through the Central Data Exchange (CDX) is
not solely for the purpose of developing improved emissions factors as some commenters assert.
Although populating WebFIRE will allow us to improve emissions factors, we intend to use data stored
in WebFIRE as the primary location for compliance test reports for use by regulatory authorities. The
electronic submission of compliance test reports is a continuation of our efforts to bring the submission
and sharing of environmental data into the modern age. The storage of this compliance data in our
WebFIRE provides a convenient location which is already used to store source test data.

As our and State and local agencies data systems mature, information provided through the ERT will be
used to populate these data systems. We are currently upgrading the AIRS Facility System and expect to
replace manually entered information with electronic population from the ERT. We are also working
with several State and local agencies to adopt the use of the ERT for delivery of compliance test reports.
The ERT is also much improved since the version used during the 2010 ICR process, and there is no
expectation that the information to be reported under this final rule will be as extensive as some of the
data reported for the 2010 ICR purposes.

We disagree that a separate and independent regulatory action is required to implement electronic
reporting for selected regulated sources. Each of these regulatory actions for selected source categories
provides ample notice and the opportunity for individuals to provide comment. We also disagree that the
system to receive the compliance data must be operational prior to establishing the requirement for
regulated sources to submit compliance data electronically. We are on track to have the capability to
receive electronic compliance tests through our CDX in sufficient time to receive all utility source test
reports required by this final rule.

We do plan a separate and independent regulatory action to implement electronic reporting for regulated
entities which are covered by past and future rules. Although we have provided draft procedures for the
development of emissions factors, that effort is an ancillary effort to the electronic delivery of
compliance test reports. It is our intention to convert to the electronic delivery and storage of all air
emissions compliance source test data. With this transition, we believe this valuable information will be
more readily available not only for compliance purposes but also for a variety of other uses.

3. Other CEMS reporting comments.

Comment 18: Commenter 18014 notes that the proposed EGU MACT Rule does not include provisions
to use the part 75 "conditionally valid data procedures." According to the commenter, this would require
the operator to invalidate the part 75 conditionally valid data (for SO2, CO2, O2 or flow monitors) for the
EGU MACT recordkeeping and reporting purposes. The commenter states that a clearer approach would
be to allow quality-assured data from a CEMS certified and operated in accordance to part 75 to be used
for EGU MACT compliance (with the exception of bias adjusted and missing data).

271


-------
Response to Comment 18: The final rule provides for certain part 75 procedures for the CEMS and
sorbent trap monitoring systems used to comply with this rule, including the use of the conditionally
valid data procedures.

Comment 19: Commenter 18449 questions why either CO2, O2 or stack moisture monitors are required
to calculate mass emissions for any pollutant. According to the commenter, reporting pollutant
concentrations on a dry or diluent basis may have been appropriate a generation ago, when point of
impingement calculations required stack output concentrations but for several decades, it has been clear
that the total mass emitted of each pollutant is what drives the environmental effects. The commenter
states that only the wet concentration and wet stack flow is required to accurately calculate the mass
emission rate of any pollutant and that adding confounding factors such as O2, CO2 or stack moisture
will only increase periods of missing data and reduce the accuracy of the reported results.

Commenter 18449 states that further input of plant heat rate or electrical output being produced is all
that is required to calculate the EPA's proposed emissions in lb/TBtu or lb/GWh. According to the
commenter, a CO2 analyzer may be required for heat input, but this is a separate issue, independent of
any individual pollutant CEMS. The commenter states that the EPA should clearly differentiate the
performance requirements for each pollutant monitor from the requirements of the additional variables
required to calculate the proposed emissions limits.

Response to Comment 19: The final rule retains these requirements, consistent with the general
approach to monitoring for this sector under part 75.

Comment 20: Commenter 18831 supports the ability to use alternatives to CEMS. The commenter
states that sources should be allowed to select CEMS, but alternatives such as stack testing should be
retained and CAM provisions developed.

Response to Comment 20: The final rule provides some alternatives, primarily CEMS or periodic stack
testing (and a PM CPMS option). We do not believe developing CAM-like provisions under this rule is
warranted as those requirements would likely be duplicative of existing control device and similar
monitoring that already applies to these sources under other programs.

272


-------
5B04 - Recordkeeping/Reporting: Electronic reporting of emissions test data

Commenters: 17316, 17621, 17638, 17681, 17718, 17719, 17725, 17730, 17767, 17770, 17775, 17790,
17795, 17816, 17820, 17821, 17868, 17881, 18014, 18498, 19033, 18023

1. ECMPS reporting of emissions test data.

a.	Support for using a modified version of ECMPS.

Comment 1: Several commenters (17638, 17681, 18023) state that the EPA should use a modified
version of ECMPS rather than the ERT to submit performance test results. The commenter states that
the EPA's proposed rule requires that performance test results be reported electronically to WebFIRE
and suggests using ERT software to do this and that the EPA has requested feedback on using a
modified version of ECMPS for this purpose. Based on problems encountered by the industry in
submitting ICR data using the ERT software, commenters suggest it would be better to use a modified
version of ECMPS rather than ERT but that revisions to the ECMPS are necessary. According to the
commenters, without revision, it may be difficult to use the ECMPS for this purpose because that system
was developed to support a trading system and not an emission limit based rule.

Comment 2: Commenter 17316 also supports the idea of using a modified ECMPS program to report
MACT test and RATA data in lieu of ERT reporting. The commenter states that as pointed out in the
preamble to this rule, electric utilities are subject to the Acid Rain Program and are familiar with
ECMPS reporting, which should facilitate the transition to MACT reporting and that SO2 RATA data is
already reported in ECMPS, so this approach would avoid some duplication.

Commenter 17316 adds that using a modified ECMPS for MACT reporting could also help promote the
development of an information system that allows ready interchange of data between the various
programs (Part 75 ECMPS and Part 60/63 NSPS/MACT ERT), serving as a sort of bridge effort.
According to the commenter, if this approach were adopted, the companion NSPS (subparts Da and Db)
regulations should also allow use of ECMPS reporting, as an alternative to ERT, otherwise for utility
units subject to NSPS, the potential consolidation benefits of reporting MACT data in ECMPS would be
lost.

b.	Opposition to using a modified version of ECMPS.

Comment 3: Commenter 17767 states that the ECMPS option would be overly burdensome as their
experience with it has shown it to be increasingly obsessed with minor data formatting issues that often
prevent the submission of data (though it might have been acceptably formatted and submitted without
issue in the past). According to commenter, it often involves many hours of manpower to correct those
issues without benefit to the quality of the key data sets or the environment. Commenter anticipates that
this would continue if MACT rule data were to be submitted via ECMPS

Response to Comments 1-3: The EPA disagrees with the commenters who feel that using the ECMPS
data collection process is overly burdensome and in the assertion that minor data formatting issues often
prevent the submission of data. The assertion points to the fact that many data reporting errors may not
have been previously caught in the past. The EPA created the ECMPS process to replace its previous
less efficient and less precise data verification systems and processes. The result of this re-engineering is
that there are significantly fewer formatting issues that prevent submissions, and a fraction of
submissions that contain critical errors at the close of each reporting period. This has added significantly

273


-------
to the EPA's ability to validate adherence to regulatory requirements, as well as, checking for the
technical accuracy of the data. The EPA has received considerable support from the regulatory
community for the revised ECMPS process, praising its efficiency and the reduction in man hours
required to report (and when necessary correct errors) using the ECMPS process as compared to the old
record type column format and ETS/MDC processes that preceded ECMPS. However, the EPA
recognizes that emissions reporting for continuously measured pollutants (S02, Hg, etc.) from CEMS is
structurally and procedurally different from what is needed to electronically collect reference method
test data for periodically measured pollutants (PM, non-Hg HAP metals etc.). Therefore, the EPA has
decided not to include detailed stack test data into ECMPS, rather will focus on only making minor
revisions to ECMPS necessary to implement the EPA's MACT data needs for continuously measured
pollutants in a manner consistent with how other CEMS monitoring requirements are currently
implemented through the ECMPS process. Doing so will minimize the structural changes to ECMPS
needed while harmonizing the data collection and reporting for CEMS systems. Because more
substantial modifications would be required of the ECMPS to accommodate the MACT data
requirements for detailed reference method test data and other periodically measured pollutants, the EPA
has decided to further develop the ERT to receive these data.

2. ERT reporting of emissions test data.

a.	Support for ERT reporting.

Comment 4: Commenters 17767 and 17795 agree with the proposed rule that the ERT would be an
appropriate means of submitting test results to the agency. Commenter 17795 states that most states will
require hard copies or electronic copies for quality assurance and acceptance. According to the
commenter, ERT provides the flexibility to upload and import supporting data, and a common system
will benefit operators with units in multiple states to have one system to generate reports for the EPA
and local regulators.

b.	Opposition to ERT reporting.

Comment 5: Several commenters (17621, 17718, 17775, 17790, 17868) express opposition to using
ERT for reporting compliance test results, and commenters (17621, 17718, 17770, 17790, 17821,
19033) state that the ERT needs extensive revision before it is used for that purpose.

Response to Comments 4-5: The EPA disagrees that the ERT needs extensive revision before it can
be used for documentation and delivery of compliance test reports for which it is designed. The EPA
also believes that with the January 2012 addition of the ability to satisfy CROMERR compliance several
state and local agencies will no longer require wet signature paper test reports. The EPA recognizes that
some state and local agencies are reluctant to adopt new programs, assess the experiences of those that
do adopt new programs and adopt new programs when they have determined the effort benefits their
program goals and available resources. The EPA believes that the use of the ERT will demonstrate to
state and local agencies that it provides them with improved ability for compliance oversight, improved
responsiveness with resources that are comparable to what they currently use to manage the paper
reports which they currently receive. As a result, the EPA expects a reduction in the number of
regulatory authorities which require the delivery of paper reports with wet signatures.

i. Performance, susceptibility to viruses, and corruption of data.

274


-------
Comment 6: Commenter 17730 notes that the EPA is proposing to use the ERT as the platform for
sources to electronically report data. The commenter states that the ERT is a Microsoft Access desktop
application that is prone to computer viruses, has created several problems in using this application, and
is subject to significant performance issues, including software crashes and shutdowns, inoperable
features (like report generation), and inadequate identification of errors preventing data analysis.
Commenter has banned the use of the Microsoft Access database system on its internal network due to
this susceptibility and is, therefore, opposed to its use for uploading data to the EPA WebFIRE database.
Commenter is concerned with the corruption of data that may occur due to the susceptibility of this
software package to virus infections. The commenter questions how the EPA would ensure that the data
that would be submitted to the WebFIRE database would not be infected and require further attention by
the EPA or by the source to rectify the information and if the EPA considered the cost of repairing a
database that is eventually corrupted by virus attack, and if so, how the repair would be accomplished
and the cost to the industry for the effort.

Response to Comment 6: The EPA implements scans and other techniques to ensure that data within its
network environment, including data submitted through CDX is free of viruses and other security
concerns. The EPA would expect that utilities would likewise ensure that the information it manages
within its network and computers remains free of viruses and is not corrupted. It is the source's
responsibility to submit complete and accurate data to the EPA.

Comment 7: Commenter 17770 provided examples of the aspects of the ERT that the commenter
considers cumbersome. The commenter states that even though the third party emission tester provided
the correctly formatted spreadsheet to import into the ERT, there were instances where the ERT would
not accept the file. According to the commenter, this resulted in manual input of the data, which was
time consuming and frustrating. Commenters 17770 and 17775 noted the program provides no useful
error messages when data were input incorrectly. The commenters state that the EPA staff were helpful
in correcting these errors, but the entire exercise only proved that the current version of the ERT is not
fully developed for everyday use.

Comment 8: Commenter 17790 states that the ERT used for submitting 2010 ICR results and had
significant flaws including: not accepting data, incompatible test methods, inoperable features.

Comment 9: Commenter 17621 observes that the ERT provides no error checking or validation
capability, and that the program failed to complete emissions calculations with no indication of the
reason. According to the commenter, the ERT could also enhance data quality by storing information
needed to understand sample results, such as results of analysis of method and field blanks and
laboratory quality control samples.

Response to Comments 7-9: The EPA recognizes that the ERT provided 2 years ago for use with the
utility ICR had some aspects of data entry that required improvement. To the extent that users identified
those issues we have modified the ERT to address the issue such that users could successfully provide
the required test report with all the necessary documentation. While the commentors may have had
difficulties with this earlier version of the ERT, the majority of the ERT's users were provided with
adequate information for use in developing the final rule. The EPA understands that the number and
detail of information required for the ICR was greater than what we require for compliance tests. The
EPA believes that with the increased familiarity in the use of the ERT combined with the revisions to the
ERT, the delivery of compliance reports to the EPA will not be a significant issue.

ii. Issues with detection limit flags.

275


-------
Comment 10: Commenter 17621 states that data flags confuse detected and non-detected results. The
EPA requires users to assign a "DLL" (detection level limited) flag to emission measurements with one
analytical fraction above detection limit and others below detection limits. The commenter notes that
this can cause a degradation of data usability.

Comment 11: Commenter 17821 states that ERT coding for method detection limits is confusing and
cumbersome; the ERT does not support the typical non-detect with a (<) symbol. The commenter states
that the ERT requires the use of bracketed symbols as a bracketed "less than" detection level value (e.g.,
[<0.0105]) and that for sample trains with multiple fractions (i.e., Method 29 Metals) this is very
confusing and increases the possibility for miscoded data.

Response to Comments 10-11: The EPA recognizes that the way the EPA required users to enter
individual laboratory components was not the most effective way to provide this information. We also
recognize the significant level of resources required of source testers to properly enter laboratory data
into their standard reports or into the ERT. This effort duplicates the resources expended by laboratories
to enter this information into the report provided to the source tester. This effort is also duplicated again
when tests are evaluated by regulatory authorities. The EPA will engage the laboratories to develop an
electronic lab report which the ERT will use to populate an expanded laboratory feature to allow for
improved capabilities for use by test contractors, state agency reviewers and the EPA.

iii.	All required emission test methods are not supported by the ERT.

Comment 12: Commenter 17821 notes that Method 30B (Hg) is not supported by the ERT in the most
current version and that in order to use the non-supported methods such as Method 3OB a supplemental
worksheet is used. According to the commenter, the use of elements outside of the ERT increases the
opportunity for errors in both data entry and data review.

Response to Comment 12: The EPA has partnered with a vendor of Method 30B hardware and
software to implement the electronic documentation of this test method into the ERT. The
implementation of 30B in the ERT will be a non proprietary application so users can use any vendors'
hardware or field software to manage the collection and analysis of the samples. This capability will be
in the version of the ERT available within 6 months following promulgation of the utility boiler MACT
standard.

iv.	ERT is burdensome.

Comment 13: Commenters 17730 and 17775 state that use of the ERT is burdensome (easily adding 10-
20 percent to the cost of compliance testing), requiring manual inputting of significant amounts of
information much of which is not relevant to performance test results. Commenter 17730 states that,
contrary to the EPA's assertion, ERT as currently designed, requires the reporting of vast amounts of
information that are not otherwise required to be reported under the applicable EPA test methods, or the
EPA's proposed rule. Commenter 17730 believes that the EPA's requirement to report electronically is
not sufficiently defined to support reporting of all the information that must be entered into ERT in order
to submit the data.

Comment 14: Multiple commenters (17718, 17621, 17725, 17790, 17816, 17820, 17881, 18014,
18498) state that using the ERT increases the cost of emission test submittal due to the time needed to
manually input significant amounts of information. Several commenters (17718, 17621, 17816, 17881)
note that manually inputting data significantly increases the potential for errors in data

276


-------
reporting. Commenters 17718 and 17816 suggest that the EPA should make the tool more user
friendly. Commenter 17881 states that using the ERT adds significant costs to the stack testing process.

Comment 15: Commenters 17730 and 17775 state that the ERT requires reporting of information that is
not otherwise required to be reported under the applicable EPA test methods, or the EPA's proposed
rule. Commenter 17730 believes that EPA's requirement to report electronically is not sufficiently
defined to support reporting of all the information that must be entered into ERT in order to submit the
data.

Comment 16: Commenter 17775 provides as examples of information required by ERT that is not
required under the EPA test methods or the proposed rule: proposed section 63.10030(a) and Table 10
require compliance with section 63.7(c). The commenter states that section 63.7(c) requires
development and, if requested by the Administrator, submission of a "site-specific test plan" to the
Administrator "at least 60 calendar days before the performance test is scheduled to take place" (i.e., at
the same time as the notification of intent to conduct a performance test) but that section 63.7(c) does
not require submission of test plan information in the performance test report which obviously is
submitted after the performance test is conducted. The commenter states that the EPA also proposes to
require compliance with section 63.7(g) (Proposed Table 10). The commenter states that proposed
section 63.7(g) requires submission as part of the "results of a performance test," "the analysis of
samples, determination of emissions, and raw data," while ERT requires reporting of much more
information, and including a test plan. The commenter states that similarly, the EPA's proposed
requirement in section 63.10031(h)(1) to report "performance test data" is not sufficiently detailed to
support reporting of all of the information that must be entered into ERT in order to submit data.

Comment 17: Commenter 19033 states that using the ERT was very cumbersome, and the reported data
was not easily reviewable.

Response to Comments 13-17: The EPA disagrees that the ERT is excessively burdensome. The EPA
does understand that some users of the ERT did not have electronic versions of field data sheets or
laboratory reports which allowed data to be imported into the ERT or that they could use to copy and
paste the applicable data. The EPA recognizes that this duplication of effort could result in an increased
burden. The EPA also understands that some field test crews preferred to use spreadsheet applications
which they developed to match their workflow and data needs. The organization of these proprietary
spreadsheet applications did not always match the organization of field data in the ERT. The EPA has
developed a supplementary field data spreadsheet module for use with a wide variety of proprietary field
data collection spreadsheet applications. We have also provided instructions for merging this
supplementary module with proprietary spreadsheet applications. When the supplementary module is
merged with the proprietary field data spreadsheet applications, the ERT will import the required
information and greatly reduce the effort in entering the field data into the ERT. The EPA is also
embarking on an effort which will allow for laboratory information to be electronically populated into
the ERT.

The EPA disagrees that the ERT requires the reporting of vast amounts of data that is not currently
required for compliance test reports. The commenters may be confusing the presence of a data field as
one that requires entry of data. Also, the commenters may be confusing the level of information the EPA
required in the ICR with what would be required for a compliance test report. The EPA made the ERT
flexible to accommodate a wide variety of existing data requirements specified by various state and local
agencies and which are specified in various published EPA test methods and published state and local
agency test methods. The EPA does not expect sources to enter data into every available field of the

277


-------
ERT for every source test. Each state or local agency which has delegated authority has provided
guidance on those data elements which they expect in compliance source tests.

v.	The EPA has provided no explanation of how WebFIRE will work.

Comment 18: Commenter 17730 states that the EPA has provided no discussion in the preamble
regarding how the information required to be submitted under ERT to WebFIRE will benefit the EPA
and sources by improving emission factors. Commenter says that the EPA has yet to explain in any
detail how the process of emission factor development from performance test data submitted to
WebFIRE will work.

Comment 19: Commenter 17775 states that the EPA is requiring reporting to ERT under provisions that
are inapplicable, inappropriate, and impossible to implement. According to the commenter, the EPA also
has provided no information to suggest that WebFIRE will be operational by the proposed January 1,
2012 deadline. The commenter stated that the proposed requirements should be withdrawn.

Commenter 17775 states that to the extent EPA wants to add subpart UUUUU data to an emissions
factor database, the EPA can do that on its own. That is not adequate justification for requiring
additional reporting by EGUs. The commenter asks that the EPA fully explain how the process of
emission factor development from performance test data submitted to WebFIRE will work. The
commenter states that in its comments on the ANPR, the commenter expressed concerns about the
process the EPA described and objected to any attempts to mandate submission of reports before the
EPA had more completely explained its plans, completed any necessary rulemakings, and made
operational its website. According to the commenter, the EPA should not be promulgating requirements
intended to support a larger program piecemeal before that program has been fully developed. The
commenter asserts that the EPA should reserve the question of mandatory reporting to WebFIRE until it
has resolved the questions raised in the ANPR.

Response to Comments 18 -19: The electronic submission of compliance test reports to the agency
through the CDX is not solely for the purpose of developing improved emissions factors. While
populating WebFIRE will allow the agency to improve emissions factors, the agency intends to use data
stored in WebFIRE as the primary location for compliance test reports for use by regulatory authorities.
The electronic submission of compliance test reports is a continuation of the agency's efforts to bring
the submission and sharing of environmental data into the modern age. The storage of this compliance
data in the EPA's WebFIRE provides a convenient location which is already used to store source test
data. As EPA and State and local agencies data systems mature, information provided in the ERT will be
used to populate these data systems. The EPA is currently upgrading the AIRS Facility System and
expects to replace manually entered information with electronic population from the ERT. The EPA is
also working with several state and local agencies to adopt the use of the ERT for delivery of
compliance test reports.

vi.	Opposition to submittal of RATA data.

Comment 20: Commenter 17718 asked that the EPA clarify whether only CEMS RATA performed
under this proposed rule are to be submitted electronically using the ERT and whether only SO2 RATAs
performed for the combined purposes of 40 CFR Part 75 and this proposed regulation would be reported
in ERT. The commenter notes that any annual NOx or flow monitor RATA performed for 40 CFR Part
75 requirements would not to be reported in the ERT even though it may have been performed
concurrently.

278


-------
Comment 21: Commenter 17775 objects to the EPA's suggestion that reporting of RATA results to
WebFIRE would be helpful in the development of emission factors. The commenter notes that RATAs
are tests of CEMS in comparison to test methods and they are performed under conditions that may or
may not be representative of operations the EPA deems relevant to emission factor development. The
commenter also objects to the required submissions of results after each "performance evaluation" since
that term is defined to include calibrations, which may be performed daily, whereas RATAs likely are
performed only once a year and considers the proposed exclusion of "opacity data" is needless, since the
rule does not require monitoring of opacity.

Commenter 17775 states that provisions for reporting in section 63.10021(a)(l l)(iv) and (v) require
sources that use PM CEMS to report "performance test data, except opacity data" and "relative accuracy
test audit data" electronically using ERT. The commenter states that in proposed section
63.1002 l(a)(17)(i) and (ii), the EPA also includes a requirement for reporting of "performance test data,
except opacity data" and "relative accuracy test audit data" for LEEs. The commenter objects to these
provisions, citing the following points: EGUs using PM CEMS and LEEs do not conduct RATAs. PM
CEMS are subject to different tests (RCAs and RRAs). According to the commenter, since LEEs
comply by initially demonstrating applicability with emission tests and thereafter by fuel analysis, LEEs
have no monitoring systems upon which to conduct RATAs. The commenter asserts that with respect to
"performance test data," the provisions are duplicative of a more general provision the EPA proposes.

Comment 22: Commenter 17881 states that all of the information the agency needs to determine an
EGU's compliance status already must be reported under the part 63 general provisions, and hard copies
of the test reports will be provided to the Administrator (and/or the delegated authority). The commenter
does not agree with submitting RATA PM data into the WebFIRE database. The commenter states that
for those monitoring systems operated pursuant to 40 CFR Part 75, RATA information is already being
submitted to the EPA in an electronic format.

Commenter 17881 disagrees with the provision to submit RATA results through the ERT. The
commenter states that the CEMS is the compliance mechanism, not the reference method data that is
collected during the RATA.

Response to Comments 20-22: We agree that it is appropriate and supportive of future regulatory
reviews that the agency collect data from CEMS RATA testing. The final rule requires that sources
submit the test reports resulting from CEMS RATAs via the CDX to WebFIRE.

vii. Use of the ERT should require rulemaking and opportunity for comment.

Comment 23: Several commenters (17730, 17725, 17775) believe it is inappropriate for the EPA to
require submission of reports through this rulemaking before the EPA has more completely explained its
plans, completed any necessary rulemakings, and made operational its website. Commenter 17730 states
that the EPA should not be promulgating requirements intended to support a larger program, piecemeal,
before that program has been fully developed. The commenter requests that the EPA provide notice and
opportunity to comment on all reporting requirements. The commenter concludes that the EPA should
set aside the question of mandatory reporting to WebFIRE until it has fully addressed these issues. The
EPA also has provided no information to suggest that WebFIRE will be operational by the proposed
January 1, 2012 deadline.

Comment 24: Commenter 17775 states that the EPA should identify the software it proposes to require
with sufficient specificity that it can be incorporated by reference into the rule. According to the

279


-------
commenter, if the EPA simply wants to require electronic reporting, the EPA should limit its
requirement to a specific format (e.g., xml) and allow sources to procure or develop their own software
to comply with that format and the associated reporting elements.

Comment 25: Several commenters (17820, 18014, 18498) state that the development of any reporting
tool or reporting format should also follow a transparent development process that includes feedback
from the regulated community.

Response to Comments 23 - 25: The EPA disagrees that a separate and independent regulatory action
is required to implement electronic reporting for selected regulated sources. Each of these regulatory
actions for selected source categories provides ample notice and the opportunity for individuals to
provide comment. The EPA also disagrees that the system to receive the compliance data must be
operational prior to establishing the requirement for regulated sources to submit compliance data
electronically. The EPA is on track to have the capability to receive electronic compliance tests through
the EPA's CDX in sufficient time to receive all utility source test reports required by this rule.

The EPA does plan a separate and independent regulatory action to implement electronic reporting for
regulated entities which are covered by past and future rules. While we have provided draft procedures
for the development of emissions factors, that effort is an ancillary effort to the electronic delivery of
compliance test reports. It is the agency's desire to transition to the electronic delivery and storage of air
emissions compliance source test data. With this transition, it is believed this valuable information will
be more readily available for not only compliance purposes but for a wide variety of other uses.

To the EPA's knowledge, there exists no standardized application for electronically documenting the
conduct of source test reports. We believe that the ERT may generate interest in the development of
software which is superior to the ERT. Should the agency see this interest, we will develop an XML
Schema for source test reports from the data elements used by the ERT. At this time, we do not know of
a private enterprise willing to develop software for source test companies to use to document field
sampling and to generate a standardized electronic output.

viii.	Hard copies of reports are needed for agency review.

Comment 26: Commenter 17719 notes that stack test data reported to state agencies must be
considered along with additional, specific information for each source's operations. According to the
commenter, this evaluation cannot be easily conducted with the limited data reported in the ERT. The
commenter believes that the stack test data submitted in the ERT, taken at face value, may be misleading
unless the context in which the testing was completed is understood. The commenter states that until the
number and degree of source configuration and operation variables can be adequately accounted for and
reported in one reporting tool, allowing the associated test data to be wholly considered, the commenter
relies heavily upon the submission of written stack test reports. Thus, the commenter supports the EPA's
preservation of the submittal of written performance testing reports to state agencies, and states that as a
state agency, it intends to continue to request sources to submit hard copies of stack test reports to the
state, in addition to the EPA's collection of stack testing data via the ERT and therefore supports the
EPA's preservation of related requirements in 40 CFR part 63, sections 63.7 and 63.10. The commenter
requests that the EPA consider a way for states to report to the EPA via the ERT that the test is not
approvable or was not representative.

ix.	Hard copies of reports should not be required.

280


-------
Comment 27: Commenters 17718 and 17816 state that a source should not be required to make paper or
other electronic submittals of the same data submitted through ERT, but should only be required to
reference data previously submitted.

Response to Comments 26-27: The EPA disagrees that the ERT is unable to store and make available
to users all the information that may be required to document the degree of source configuration and
operating variables. The ERT provides the ability for the documentation of process operating
parameters, laboratory analyses of parameters associated with the process, text descriptions of process,
controls, monitoring methodologies and descriptions of testing issues which can be migrated into larger
data systems if desired. In addition, the ERT is capable of storing a variety of formats of electronic
documents including but not limited to word processing files, spreadsheet files, scanned image files, and
ISO standard ISO 32000-1:2008 compliant Portable Document Format files. The continued delivery of
only a paper version of source test reports will continue to limit the availability of the information
contained in these reports to the individual which receives the report. This will also limit the information
which is available to others within the state/local agency, EPA and those needing access to this
information to that information that the recipient manually enters into a widely available data system.
The EPA believes that it is much more efficient to allow electronic population of data systems and
electronic screening of source tests requiring increased scrutiny. The EPA recognizes that states with
delegated authority may require sources to provide complete reports in paper form. However, these
paper reports with be in addition to the delivery of electronic reports through the EPA's CDX. The EPA
encourages state and local agencies to accept electronic reporting in lieu of a paper report.

x.	Cross-media Electronic Reporting Rule.

Comment 28: Commenters 17730 and 17775 state that any electronic report used to satisfy federal
reporting requirements also must meet the requirements of the Cross-Media Electronic Reporting Rule,
codified at 40 CFR part 3, including the requirement that the document include a valid electronic
signature, as defined in the rule. Commenter asks that the EPA explain how ERT or WebFIRE meets
this requirement and whether ERT can satisfy other criteria the EPA deems necessary for valid
electronic reporting, including whether (i) each electronic signature was a valid electronic signature at
the time of signing; (ii) the electronic document cannot be altered without detection at any time after
being signed; and (iii) each signatory had the opportunity to review in a human readable format the
content of the electronic document that he or she was certifying to, attesting to, or agreeing to by
signing. The commenter is concerned that the responsible official is unable to prevent revision of the
information in ERT at or after the point of submittal.

Response to Comment 28: Submission of the ERT Project Data file through EPA's CDX will be fully
compliant with the Cross-Media Electronic Reporting Rule. This includes the signature validation of the
authorized official of the regulated source, the addition of electronic means to verify that no changes in
the file were made subsequent to submission and the opportunity to review in the test report in a human
readable format. As with a wide variety of electronic submissions through the EPA's CDX, the original
file submitted to the agency will be maintained with proof of the original signature and proof that the file
has not been altered. A copy of the file of record will be stored in WebFIRE and is not required to be
CROMERR compliant although the agency does not expect to modify the file. Users requiring
verification of the authenticity of the contents of the file will be directed to the CDX where the official
copy of record will reside.

xi.	Paperwork Reduction Act.

281


-------
Comment 29: Commenters 17730 and 17775 state that to comply with the Paperwork Reduction Act
and its implementing regulations, the EPA must specifically identify each piece of information it seeks
to have reported, explain how those data have practical utility, and estimate the costs of collection and
the EPA review of those data. According to the commenters, the EPA has not appropriately responded to
these requirements in the proposal. Commenters state that if the EPA intends to require reporting of
more than the test results already required to be reported under the applicable EPA test methods, the
EPA must issue a supplemental proposal identifying and soliciting comment on the information it seeks
to collect so that the regulated community and members of the public may have an opportunity to
adequately respond to the proposed requirements.

Response to Comment 29: While the ERT may have the ability to store a wide variety of information,
there is no information required by the ERT which is not required in this rule or in those source test
methods used for demonstrating compliance with this rule. There may be information which are required
by the delegated authority but are not stipulated in this rule or test method required by this rule.

282


-------
5B05 - Recordkeeping/Reporting: Other

Commenters: 17197, 17681, 17691, 17725, 17775, 17820, 17881

1.	Electronic reporting.

Comment 1: Commenter 17197 notes that the December 31, 2011 date in section 63.1002l(a)(16)(vii)
appears erroneous since it specifies compliance notifications that are due long before the rule's 3-year
implementation and compliance deadline from final rule Federal Register publication. The commenter
also notes that the referenced (CDX) electronic data reporting capability will be available beginning
January 1, 2012. The commenter recommends that the date references in the proposed rule be replaced
by a time reference (i.e., 180 days, 6 months, 12 months) from final publication of the rule.

Comment 2: Commenter 17881 states that due to the lack of specificity in the data to be submitted as
required by section 63.1002l(a)(16)(vii), the regulated community will not know how to comply with
this requirement; it needs clarification. The commenter states that the EPA database does not currently
exist, and therefore it is not possible to constructively comment on this requirement.

Response to Comments 1-2: The EPA believes the revisions in the final rule address the calendar date
issues, as well as the concerns with proposed section 63.1002l(a)(16)(vii).

2.	Performance test notification time.

Comment 3: Commenter 17681 asks that the EPA choose 15 days or 21 days rather than the 30 days of
notification before performance testing required in section 63.10030(d) of the proposed rule.

Comment 4: Commenter 17691 asks that the EPA require at least 60 days of notification rather than the
30 days of notification before performance testing required in section 63.10030(d) of the proposed rule.

Comment 5: Commenters 17775 and 17820 state that the proposed requirements for notifications to
conduct performance tests and compliance status are unclear. The commenters state that proposed
section 63.10030(a) requires submission of all of the notifications required under the General Provisions
of 40 CFR part 63 (specifically section 63.7(b) and section 63.9(e)), proposed Table 10 also identifies
section 63.7(b) and section 63.9 as applicable, sections 63.7(b) and 63.9(e) require notification of "intent
to conduct a performance test at least 60 calendar days before the performance test" is initially
scheduled to begin, but that proposed section 63.10030(d) requires submission of a "Notification of
Intent" to conduct a performance test, "at least 30 days before the performance test is scheduled to
begin." The commenters state that this inconsistency should be corrected in the final rule and provide
clarity as to whether the 30-day or 60-day notification will be required.

Response to Comments 3-5: The final rule requires 30-day notice of all performance tests, and
clarifies any discrepancy with the general provisions.

3.	Multiple reporting requirements.

Comment 6: Commenter 17775 expresses concern that the proposed rule contains redundant
requirements for reporting. The commenter states that in section 63.10031 and Table 10, the EPA
proposes to require compliance with most of the reporting requirements in the part 63 general
provisions, including requirements for submission of "performance test results" under section

283


-------
63.10(d)(2), "performance evaluation results" under section 63.10(e), and "excess emissions and
continuous monitoring system performance reports" under section 63.10(e)(3). The commenter states
that according to section 63.7(g) (applicable under proposed Table 10), performance test results must be
submitted as part of the "notifications of compliance status" under section 63.9(h) and must include
"analysis of samples, determination of emissions, and raw data"; under section 63.8(e)(5), performance
evaluation results, which include results of "relative accuracy testing" and "calibration error tests" also
must be submitted simultaneously with any performance test results(40 CFR 63.2)(applicable under
proposed Table 10); And that "Excess emissions and continuous monitoring system performance
reports" are submitted semi-annually, and must contain the information in section 63.10(c)(5) through
(13), section 63.8(c)(7), and 63.8(c)(8)." The commenter states that according to proposed Table 10,
some of the provisions in section 63.10(c) are not applicable to subpart UUUUU, and that because the
reports are to include information on "excess emissions" "as defined in the subpart, and subpart
UUUUU does not define "excess emissions," these provisions are not complete. The commenter asks
that the EPA address these inconsistencies and omissions prior to finalizing the rule.

Commenter 17775 notes that performance test results and notifications of compliance must be sent to
the state, the EPA Regional Office and permitting authority (if different than the state). The commenter
states that as a result, under the part 63 general provisions alone, most EGUs already will need to
prepare and submit three types of reports (in addition to the notification of compliance status) to both the
EPA Regional Office and at least one state office: (1) performance test reports, (2) performance
evaluation reports for monitoring systems, and (3) excess emissions and monitoring system deviation
reports. The commenter states that proposed section 63.100031(h)(3) also requires a hard copy of the
ERT reports to be sent to the Administrator, bringing the number of copies of each performance test and
performance evaluation report submitted up to at least four.

The commenter further notes that in addition to the semi-annual "excess emissions and continuous
monitoring system performance reports" required under section 63.10(e), EGUs would submit the
additional information specified for a semi-annual "compliance report" described in proposed section
63.10031 and Table 9. The commenter states that this information presumably includes the "deviation"
reports referenced in the preamble. The commenter believes that this is excessive.

Commenter 17881 states that as proposed in section 63.10030(d), there will be limited time to submit a
test plan and notice and to receive agency approval, let alone receive and review results from previous
test events, prior to the next test event. The commenter suggests that one test notice or report be
submitted for all testing conducted within a semi-annual period (or some other reasonable time frame).

Response to Comment 6: The agency agrees with the commenter's assertion that there is a potential for
duplicative reporting. To the extent possible, the rule has been revised to eliminate reporting to both
States and permitting authorities where the state is the permitting authority. The rule eliminates
duplicative reports to EPA Regional Offices. The agency agrees that clarification is needed so that
duplicate copies of the same report do not need to be submitted more than once, and the rule has been
revised to eliminate the requirements for more than one copy of any report.

The agency agrees with the commenter regarding the unclear requirements for excess emissions and
deviation reports, and the rule has been revised to clarify that all of these reports are excess emissions
reports which are referenced in the General Provisions of part 63. Also, the agency is aware that the
rule's exceptions to the General Provisions reporting, as shown in Table 9, will reduce burden on what
the facilities need to submit.

284


-------
The agency is aware of and agrees with the commenter that there needs to be a clear definition of excess
emissions; the rule contains such a definition.

Generally, providing adequate notice of and receiving approval of emissions testing are non-federal
requirements; should an EGU owner or operator believe timing to be problematic, the rule affords the
owner or operator the ability to choose means other than emissions testing to demonstrate compliance.

4.	Section 63.10031(c)(7).

Comment 7: Commenter 17881 asks if, assuming that paragraph 63.10031(c)(7) only pertains to units
not using CEMS, that can burn the new fuel without meeting the Hg and HC1 input operating limits, as
long as you perform a compliance test within 60 days and if the test shows compliance, whether there is
a deviation to report.

Response to Comment 7: If you combust a new fuel, you must conduct a performance test for that fuel.
There are no input operating limits, but you must show compliance with the applicable emission limit.
Performance test results must be submitted, but assuming the tests show compliance, there is no
deviation to report with respect to the emission limit.

5.	Notice of Compliance.

Comment 8: Commenters 17775 and 17820 ask that the EPA clarify if some EGUs are not required to
submit a Notice of Compliance Status or revise the section to make clear that all EGUs must submit
such a notice, citing inconsistencies between requirements in section 63.10031(e) and section
63.10005(a). The commenters note that proposed section 63.10031(e) requires EGUs to submit a
"Notification of Compliance Status" according to section 63.9(h)(2)(ii), "[i]f you are required to conduct
an initial compliance demonstration as specified in § 63.10011(a)" but that under proposed section
63.10005(a) all EGUs "must demonstrate initial compliance with each of the applicable emission limits
in Tables 1 or 2..." and that, section 63.9(h) on its face applies to each affected source when it becomes
subject to a relevant standard.

Commenter 17775 states that under paragraph (3), the Notification of Compliance Status must include
"[identification of whether you plan to demonstrate compliance with each applicable emission limit
through performance testing and fuel analysis; performance testing with operational limits (e.g., CEMS
for surrogates or CPMS); CEMS; or sorbent trap monitoring system." The listed options do not appear
to correspond with the rest of the proposed rule. The EPA needs to issue a proposal that clearly
articulates the various compliance demonstration options.

Commenter 17775 states that under paragraph (3), the Notification of Compliance Status must include
"[ijdentification of whether you plan to demonstrate compliance with each applicable emission limit
through performance testing and fuel analysis; performance testing with operational limits (e.g., CEMS
for surrogates or CPMS); CEMS; or sorbent trap monitoring system." The listed options do not appear
to correspond with the rest of the proposed rule. The EPA needs to issue a proposal that clearly
articulates the various compliance demonstration options.

Response to Comment 8: The language cited in the first paragraph above has been changed to "initial
performance test," so that, for example, the notification requirement does not apply to the work practice
standard and performance tune-up. The language in section 63.10030(e)(3) cited in the second paragraph
has been revised to clarify the compliance options consistent with the final rule.

285


-------
6. SSM reporting.

Comment 9: Commenter 17725 suggests that the EPA consider reporting startup, shutdown, and
malfunction reports listed in Table 9 to subpart UUUUU of part 63 Reporting Requirements via email so
notification can be made concurrently to any necessary state or local reporting agencies as well.
According to the commenter, this would also allow for a document trail to be maintained and eliminate
the unnecessary use of maintaining both paper and electronic records.

Response to Comment 9: The general provisions apply similar to other NESHAP and the specific
applicability of the General Provisions to EGUs is addressed in Table 9 of the final rule. Notices are
required to be delivered or mailed to the address specified. A courtesy email may be sent as an unofficial
notification.

286


-------
5C01 - Compliance: Dates

Commenters: 15678, 16122, 16469, 16705, 16824, 16849, 16850, 16856, 16858, 17003, 17004, 17022,
17026, 17028, 17055, 17055, 17110, 17123, 17137, 17174, 17254, 17265, 17297, 17383, 17385, 17400,
17402, 17403, 17406, 17408, 17608, 17623, 17627, 17637, 17638, 17640, 17648, 17654, 17655, 17656,
17675, 17677, 17681, 17689, 17696, 17697, 17701, 17703, 17705, 17707, 17711, 17714, 17715, 17716,
17718, 17719, 17720, 17722, 17724, 17725, 17730, 17731, 17732, 17734, 17735, 17736, 17738, 17740,
17741, 17752, 17756, 17757, 17758, 17761, 17765, 17767, 17770, 17774, 17775, 17776, 17789, 17790,
17791, 17796, 17797, 17798, 17799, 17800, 17805, 17807, 17808, 17810, 17812, 17813, 17815, 17816,
17817, 17818, 17819, 17820, 17821, 17824, 17829, 17834, 17837, 17840, 17841, 17842, 17843, 17844,
17846, 17852, 17854, 17856, 17857, 17868, 17870, 17873, 17876, 17877, 17878, 17879, 17881, 17883,
17885, 17886, 17887, 17902, 17904, 17909, 17911, 17912, 17913, 17918, 17919, 17925, 17930, 17931,
17973, 18016, 18021, 18024, 18025, 18026, 18027, 18031, 18033, 18034, 18037, 18038, 18039, 18419,
18421, 18422, 18422, 18424, 18425, 18426, 18428, 18430, 18433, 18434, 18437, 18438, 18439, 18440,
18441, 18442, 18447, 18448, 18450, 18477, 18487, 18498, 18500, 18501, 18502, 18539, 18541, 18575,
18933, 19032, 19114, 19121, 19122, 19212, 19213, 19506, 19653, 8443, 9738, 19536, 19537, 19538,
18023

1. General comments.

Comment 1: Multiple commenters (16850, 16858, 17004, 17022, 17026, 17028, 17110, 17654, 17689,
17715, 17724, 17740, 17797, 17820, 17821, 17868, 17909) ask that the compliance date be clearly
stated as soon as possible, as well as guidance for utilities unable to comply with the stated timelines, to
allow time for utilities to prepare.

Response to Comment 1: The compliance date for the final rule is set forth at 40 CFR 63.9984. New
sources must be in compliance with the standards on the effective date of this rule or at start-up,
whichever is later. Existing sources must be in compliance 3 years after the effective date of this rule. .
Three years is the maximum compliance time authorized under the statute. See CAA section
112(i)(3)(A). If sources are unable to comply within 3 years, the owner or operator may seek a 1 year
extension of the compliance period from its Title V permitting authority if the source needs the
additional time to install controls necessary to comply with the final rule. See CAA section 112(i)(3)(B).

The EPA sends rules to the Federal Register once they are signed. We do not know exactly when the
rule will be published in the Federal Register but it is likely to take a month or more. As we have stated
elsewhere, we believe utilities should already be in the process of planning for compliance with this
regulation.

Comment 2: Multiple commenters (17174, 17265, 17648, 17654, 17681, 17689, 17740, 17774, 17796,
17820, 17821, 17868, 17873) ask that any decisions or policies on extensions be published in a
rulemaking.

Comment 3: Commenters 18034 and 18447 request clarification on what actions the federal
government will take to ensure reliability. Commenter 18034 also recommends the EPA clarify any
possible discretionary enforcement the EPA may plan to exercise for states that may receive delegation
of the new rule.

Commenter 18034 states that EPA makes several vague statements about steps to ensure a reliable and
reasonably-priced supply of electricity, particularly regarding localized issues, but does not provide any

287


-------
details concerning what authority would be exercised. The commenter states that in one discussion (76
FR 24979), the EPA indicates that the federal government will work with companies to ensure a reliable
and reasonably priced supply of electricity, and in a separate discussion (76 FR 24979), the EPA states
that they believe they have the ability to work with companies making good faith efforts to comply with
the standards so that consumers in those areas are not adversely affected. According to the commenter,
the EPA should be clear about the steps it may take and what the federal government might do to
provide all parties the opportunity to comment on the appropriateness and legality of the actions that the
EPA and other agencies of the federal government are considering. The commenter states that
additionally, states that might receive delegation of this regulation should be made aware of possible
discretionary enforcement the EPA may plan on exercising. The commenter states that rather than
pointing to vague steps that the EPA and the federal government may take to address electrical power
system reliability problems after they occur, the EPA should be considering the consequences of their
actions on the electrical power system and building an adequate safety margin into their rulemaking
efforts to ensure that the electrical power system of the country is protected.

Commenter 18447 states that EPA states in the proposal preamble that "the Federal government will
work with companies to ensure a reliable and reasonably-priced supply of electricity." The commenter
asks "How does the Federal government propose to fulfill this promise?" The commenter points out that
maintaining generation capability and output from their facility is very important not only for satisfying
the electrical demand (load) of the City of Ames and Iowa State University, but also for providing
voltage support and electrical stability to the interconnected electric system of central Iowa. The
commenter further notes that the impacts on the planning reserve margins and the need for more
resources is a function of the tight compliance timeline associated with the proposed rules. "Potential
constraints of skilled construction labor, material shortages, financing, and escalation of compliance
costs coupled with coordination of overlapping outages resulting in congestion expense could present
challenges in meeting the compressed time schedule," NERC concluded.

Response to Comments 2 and 3: Some commenters asked that EPA, by rulemaking, extend the
compliance timeframe for this regulation. Many of these commenters wanted the certainty that including
the compliance timeframe through rulemaking would afford. Some of these commenters suggested
unique situations where providing the extension could be crucial. Public power facilities might need
additional time because many of them must obtain approval from public bodies for the compliance
activities that might require a public process that can be time consuming. Some commenters felt that
smaller facilities would have difficulty procuring the engineering, labor and equipment needed for
compliance. CAA section 112 specifies the dates by which affected sources must comply with this rule.
New or reconstructed units must be in compliance immediately upon startup or the effective date of this
rule, whichever is later. Existing sources may be provided up to 3 years after the rule's effective date to
comply with the final rule; if an existing source is unable to comply within those 3 years, a permitting
authority has the ability to grant such a source up to a 1-year extension, on a case-by-case basis, if such
additional time is necessary for the installation of controls.

The CAA allows CAA title V permitting authorities the discretion to grant extensions to the compliance
time of up to one year if needed for installation of controls. See CAA section 112(i)(3)(B)). Permitting
authorities should be familiar with the operation of the 1-year extension provision because EPA
established regulations to implement the provision and the provision applies to all NESHAP. See 40
CFR 63.6(i)(4)(i).

We believe that the permitting authorities have the discretion to use this extension authority to address a
range of situations in which installation schedules may take more than 3 years.

288


-------
The EPA's authority to provide relief from the requirements of this final rule beyond the fourth year is
limited by the statute. If reliability issues do develop, however, the CAA provides mechanisms for
sources to come into compliance while maintaining electric reliability. One area where the EPA has
some measure of flexibility is with respect to the exercise of its enforcement authorities. Please see the
preamble to the rule for an in depth discussion of both the 1-year extension and authorities beyond the
fourth year.

Comment 4: Multiple commenters (17402, 17403, 17623, 17648, 17714, 17740, 17774, 17799, 17808,
17858, 18021, 18034, 18450, 18500) ask that the EPA establish, streamline, and simplify the process of
applying for the 1-year extension under section 112(i)(3).

Commenter 17403 suggests that a commitment to install wet or dry scrubber, fabric filter, DSI, or other
major emissions control equipment would automatically qualify the particular unit for the extension.

Several commenters (17808, 17648, 18450) suggest that companies requesting an extension have a
compliance plan outlining the steps and timing of the project. Commenter 17648 also suggests operating
criteria that must be maintained during the extension, to minimize emissions and remove any economic
incentive of deferring compliance.

Commenter 17797 asks that the EPA outline the conditions in which an additional year for compliance
with the proposed regulations would be granted. The commenter requests that power companies be
allowed to operate on a restricted basis without additional controls as they upgrade their facilities.

Response to Comment 4: The EPA established General Provisions applicable to CAA section 112
standards at 40 CFR part 63, subpart A. Included in those provisions are regulations implementing the 1
year compliance extension provision of CAA section 112(i)(3)(B). See 40 CFR 63.6(i)(4). The EPA did
not propose to revise those regulations for EGUs in the proposed rule and we are not issuing
amendments to those provisions in the final rule. We believe that sources should make themselves
familiar with the regulations and contract the state permitting authority as early as possible if the source
determines that it will need a 1 year extension.

Comment 5: Multiple commenters (17403, 17623, 17714, 17758, 17774, 17799, 17868) ask that the
EPA develop procedures and criteria related to the Presidential exemption under section 112(i)(4).
Multiple commenters (17758, 17820, 17868, and 18539) ask that the utility demonstrate good faith
progress toward compliance.

Response to Comment 5: The EPA is not authorized to implement the Presidential exemption provision
in CAA section 112(i)(4). That provision authorizes the President to provide 2-year renewable extension
for sources to comply with the final standards if he determines that the technology to comply with the
rule is not available and the extension is in the national security interest of the U.S.

Comment 6: Commenter 17808 suggests that the EPA require utilities to submit a notice concerning
which EGUs will be retrofitted or retired - within 1 year of the effective date.

Comment 7: Several commenters (17701, 17791, 18034) encourage the EPA to coordinate with FERC,
DOE, and state and federal regulators to maintain system reliability. Commenters 17701 and 17791
suggest the EPA develop a process that will require all generators to provide notice to FERC, system
operators, and state regulators of expected effects of the EGU MACT and other EPA regulations. The

289


-------
commenters believe that such a process would provide an opportunity for meaningful assessment and
response to reliability issues. Commenter 18034 recommends the EPA work closely with the regional
agencies, such as (PUCT and ERCOT) that are responsible for monitoring and assuring the reliability of
the electrical power system to ascertain the impact of the new rules on Texas' and the nation's electrical
power system.

Commenter 17824 urged the EPA to adopt more flexible standards and reasonable compliance timelines,
which will achieve the Agency's goals while ensuring affordable utility bills, stable jobs and reliable
power.

Response to Comments 6-7: The EPA is not requiring that sources provide notice within 1 year of the
effective date of the rule, as to which units will retire and which units will be retrofitted to comply with
the final rule. However, the Agency does encourage facility owners to notify the permitting agencies, the
transmissions operators, and state regulatory agencies as early as possible of their intention to retrofit or
close. Early notification will help to ensure that permitting is orderly and timely for plants that are
retrofitting. It would also provide transmissions operators an early heads up so that they can plan for
transmission upgrades to avoid reliability problems. It would also allow market solutions including new
generation and demand side management solutions to come into the market and ensure grid stability.

Comment 8: Commenter 17648 suggests a process based on early notification of retirements.

Comment 9: Commenter 18441 asserts that the 3-year time period is insufficient for making necessary
transmission upgrades. They argue that although certain local reliability upgrades such as those that
entail upgrades to existing substations can occur in an expeditious manner, other kinds of transmission
upgrades may involve far more complex projects with extended delays. The commenter provides the
following three examples to support their statements:

•	The need for the Susquehanna-Roseland line was first identified by PJM and approved by the
Board as part of 2007 RTEPP and was anticipated to be in service for 6/1/2012 to avoid
identified reliability criteria violations. However, they note that delays due to National Park
Service review have delayed the in-service date of this line to 2015 at the earliest.

•	The retirement by Exelon Generation of the Cromby Unit 2 and Eddystone Unit 2 requires 18
separate transmission system enhancements to address the identified thermal, voltage and short
circuit violations. The commenter notes that even though Cromby and Eddystone provided
notice of deactivation in December, 2009, due to the need for such transmission enhancements
the units are not going to actually shut down until May, 2012.

•	A deactivation request for the Benning Road and Buzzard Point generating units (totaling 790
MW, located in the Potomac Edison Power Company's zone in Washington, D.C.) was
submitted with PJM in February, 2007. Transmission reinforcements necessary to allow these
generating units to retire, which include new circuits, upgrades to existing circuits, new
transformers, new capacitors and upgrades to existing terminal equipment, are not expected to be
in service until more than five years after such notice in May, 2012.

The commenter states that the analysis supporting the Proposed Rule has underestimated the risks to
reliability of electric supply in light of the hard deadlines imposed pursuant to Clean Air Act § 112.
Moreover, as EPA indicated, unit owners must only give 90 day notice prior to shutdown in the PJM
region, 76 FR 25056. According to the commenter, the requirement to be in compliance three years
following publication in the federal register, 40 CFR §63.9984, may result in the shutdown of certain

290


-------
units that are critical to the reliability of electric supply on a timeline that is faster than the time
necessary to replace the power or upgrade transmission.

Comment 10: Multiple commenters (17716, 17701, 17791, 17804, 17813, 18034, 17868, 17911, 17913,
17919, 18441, 19114, 18034, 18441, 18500, 18538) express concern that the EGU MACT may cause
local transmission problems due to early retirement of EGUs. These commenters argue that the EPA
should have assessed reliability at much more local level rather than relying only on national studies of
reliability. Commenter 18034 notes that ERCOT anticipates localized impacts on transmission reliability
in the Houston and Dallas-Fort Worth areas as a result of the EGU MACT and other EPA regulations.
Commenter 17701 notes that small older plants that would likely retire as a result of the EGU MACT
and other environmental regulations may need to stay running for a longer period of time because they
provide service to an area that cannot otherwise get reliable power (a load pocket) or they provide a key
reliability service (e.g., black-start facilities). Commenter 17919 believes that those areas most reliant
upon coal-fired capacity are likely to face profound price, supply, and reliability concerns and that in
the event of extraordinary events, only the additional peak-load capacity supplied by coal-fired facilities
are likely to provide the resilience necessary to address potential weather-related blackouts or even
cyber-security threats to critical infrastructure. Commenter 17731 believes that reduced grid reliability
will be exacerbated by heavier reliance on non-final (i.e., interruptible) transmission and gas
transportation contracts that can result in curtailed deliveries of energy during peak periods when the
energy is most needed.

Comment 11: Commenter 17716 considers the EPA to be downplaying transmission problems related
to compliance. The commenter notes that transmission problems can arise because current paths are not
used after plant retirement, or new/expanded transmission paths are needed for purchased power to
replace that from retired plants.

Comment 12: Commenters 17868 and 18500 mention recent blackouts in the ERCOT region of Texas
as an example of localized reliability problems resulting from too many units out of service at one time
during a cold weather event. Commenter 17868 suggests the EPA review the Texas PUC report on the
February 2-3, 2011 outage in Texas to understand the implications of reduced electricity supply. The
commenters believe this event is an important reminder that having generation offline for upgrades even
during a low load season has its risks.

Comment 13: Several commenters (17912, 18034, 18441, 18538, 18023) believe a more detailed study
of the impacts of the EGU MACT on reliability of the electric network should be undertaken by the
EPA. These commenters identify several areas in which they believe the EPA's analysis of reliability
impacts is incomplete or inaccurate.

1.	Commenter 17912 believes the EPA's assessment of the impact of the rule on reliability failed to
take into account differences between IPPs and regulated utilities. The commenter notes that IPPs do
not have a regulated utility's ability to shift load to other units because many IPP facilities are
subject to regional reliability mandates that require firing with oil.

2.	Commenter 18538 believes the EPA has overstated the ability of energy efficiency and demand
response programs to mitigate the reliability impacts of the various EGU rules.

3.	Commenter 18538 believes the EPA has understated the reliability impacts of the rule by using low
target reserve margins. In the ERCOT region, the commenter argues that the EPA uses a target
reserve margin of 12.5% instead of the 13.75% used by ERCOT for planning purposes. The
commenter believes the EPA's target margin would likely result in greater incidence of system
outages than is considered acceptable in the electric industry. According to the commenter, ERCOT

291


-------
adopted its 13.75% minimum reserve margin based on the results of a loss-of-load study, which is a
probabilistic assessment of the likelihood of a system outage event. The commenter states that the
study takes into account components of system volatility, including the forced outage and derating of
generating facilities, load forecast uncertainties resulting from weather, and the intermittent nature of
wind generation and that consistent with industry practice, ERCOT sets its minimum reserve margin
at a level such that the expected frequency of a loss-of-load event is no more than 1 day in 10 years.
According to the commenter, the EPA's target reserve margin of 12.5% would increase the
likelihood of a loss of load event from 1 day in 10 years to approximately 2.5 days in 10 years. By
using a target reserve margin below that required by ERCOT, the commenter argues that the EPA
has understated the impact of the various rules on electric reliability in the ERCOT region.

4.	Commenter 18034 notes that the EPA's modeling assumes unlimited transmission capability within
a model region (e.g., power generated anywhere in ERCOT can be transmitted anywhere in ERCOT)
and states that this is not correct. The commenter notes that electrical power cannot be transmitted in
an unlimited manner from anywhere to anywhere within a region as large as ERCOT and that
fundamental principles of electrical transmission, such as thermal restrictions on transmission lines
and voltage stability, restrict the distance that power can be transmitted over power lines within a
region.

5.	Commenter 18034 questions whether the EPA's analysis accounted for units classified as
Reliability-Must-Run (RMR) facilities that are necessary to ensure grid reliability in specific local
areas.

6.	Commenter 18034 notes that the 25% surplus reserve margin that the EPA cites as an indication that
projected retirements will not affect reliability is a national average and is not consistent with
ERCOT's local projections for Texas. The most recent information from ERCOT, they argue,
indicates that the ERCOT region currently has 17.5% of surplus reserve (Report on the Capacity,
Demand, and Reserves in the ERCOT Region, May 2011); however, ERCOT expects this surplus
reserve will drop to 11.1 % by 2014 even without impacts of the EPA's regulatory initiatives, which
is less than ERCOT's target reserve of 13.75%.

7.	Commenter 18034 believes the EPA has also over-estimated the generation potential of wind energy.
They note that ERCOT derates wind capacity using an 8.7% capacity factor because wind generation
is unpredictable and unreliable as a generation source. The EPA appears to be assuming that wind
generation is capable of producing at 100% of the installed capacity, which is not correct and results
in the EPA over-estimating wind capacity in ERCOT by 9,400 MW.

8.	Commenter 18034 states that the EPA included retired and mothballed units in their capacity
calculations. The commenter notes that the actual total generation resource capacity for ERCOT is
73,175 MW, based on the May 2011 ERCOT report, which is substantially less than the EPA's
estimated 90,400 MW for the base case. A recent ERCOT study, entitled Review of the Potential
Impacts of Proposed Environmental Regulations on the ERCOT System, issued on May 11, 2011, the
commenter asserts, finds that without additional replacement generation the reserve margins could
be reduced to less than 2% by 2015 as a direct result of the EPA's regulatory initiatives on EGUs.

9.	Commenter 18441 argues that the EPA analysis erroneously assumes (1) wholesale power markets
mirror least-cost planning models; reliability is related to only movements of power between large
geographic areas; and (2) that there are no transmission or deliverability constraints within those
areas. These errors, the commenter argues, result in conclusions that are not correct for RTOs. The
commenter notes that retirement and new entry decisions are made in a decentralized manner based
on price signals that are provided by wholesale markets that signal the financial profitability of
existing and new entry resources. The commenter states that in contrast, the IPM employed by the
EPA to model reliability impacts does not reflect the manner in which decisions are made in the
wholesale market. According to the commenter, the objective of the IPM is to minimize the system-
wide, region-wide, or nation-wide cost of achieving resource adequacy and maintaining its

292


-------
representation of transmission reliability subject to the environmental constraints imposed on
generating units by the proposed rule. The commenter states that in sharp contrast to market
dynamics, in the IPM modeling framework employed by the EPA, the retirement and new entry
decisions are centralized; the decisions, are not based on market price signals and do not depend
upon unit profitability or returns on investment. Rather, according to the commenter, the decisions
are based on cost and perfect foresight of future market conditions. As a consequence, the
commenter believes the IPM model may reflect retirement and new entry decisions that differ
significantly from the actual market-based retirement and new entry decisions.

10.	Commenter 18441 notes that the IPM framework does not account for Demand Response and
Energy Efficiency resources as new capacity entry or account for the effect these resources may
have on market prices that drive retirement and new entry decisions. The commenter notes that
wholesale energy and capacity markets in PJM allow for the participation of Demand Response and
Energy Efficiency. According to the commenter, since these resources are generally lower cost
capacity alternatives than traditional generation resources, the commenter argues that they can have
an effect on market prices and ultimately on the retirement and new entry decisions of generation
resources when considered in conjunction with the costs imposed by the EGU MACT. The
commenter believes the IPM framework is likely missing possible generation retirements that may
be driven by the interaction of the EGU MACT with these potentially lower cost capacity resources.
The commenter is concerned that the EPA's analysis understates the volume of system security and
local reliability issues faced by RTOs and other transmission operators.

11.	Commenter 18447 states that the IPM modeling of regions misses large 500 kilovolt ("kV") reactive
transfer interfaces that reside within some of the regions. The commenter also notes that some of the
regions span across multiple RTOs and each RTO region undertakes its own security constrained
generation dispatch. According to the commenter, the manner in which power is moved from one
region to another in IPM does not account for parallel path or loop flows that occur across multiple
regions and the international border between the U.S. and Canada that take careful inter-regional
coordination between multiple RTOs and transmission providers to solve. The commenter notes that
the recent Independent Market Monitor ("IMM") reports for PJM states that the amount of
generation available to be redispatched to alleviate localized constraints to maintain transmission
security is small, sometimes only one or two generating units have the ability to relieve such
localized constraints. The commenter argues that the deactivation or retirement of some generation
would take away potential re-dispatch solutions and therefore likely trigger the need for transmission
upgrades to prevent transmission reliability criteria violations. The commenter notes that more than
half of all the pending deactivations require transmission upgrades to allow the unit to retire without
a violation of transmission reliability criteria.

12.	Commenter 18023 believes that the EPA's analysis is overly simplistic and incorrectly assumes that
demand response, energy efficiency, and rapid and wide-spread deployment of renewable energy
resources will sufficiently replace lost coal-fired generation capacity both from a resource adequacy
and bulk power system operations standpoint. The commenter argues that renewable generation
resources and demand response do not provide inertia, frequency response, or voltage support.

13.	Commenter 18023 believes that the EPA has underestimated the impact that a decrease in available
generating resources will have on the ability of authorities to comply with the reliability standards.
The commenter believes the EPA's failure to take into account mandatory BAL and VAR reliability
standards (among others) in its discussion of reliability impacts of the Utility MACT is a significant
error. The commenter argues that violations of the reliability standards have a wide variety of
negative consequences for the electric system, including load shedding and black-outs. The
commenter notes several potential operating reliability impacts of the Utility MACT rulemaking:

293


-------
•	Contingency Reserves: requires resources sufficient to address system disturbances; 50 % must
be "spinning reserves" {i.e., reserve capacity at units already on-line);

•	Load-Following Reserves: requires resources sufficient to respond to load changes within an
hour;

•	Regulating Reserves: requires resources sufficient to control system performance by responding
within 4-6 seconds; all regulating reserve must be "spinning";

•	Frequency Control: requires sufficient resources capable of automatically and instantaneously
responding to changes in frequency caused by constant tracking and matching of power demand
and power supply to prevent imbalances;

•	Voltage support: needed to enable the transmission of electricity over distance. Grid operators
must ensure there is enough reactive power at the right locations to support the electricity that is
being delivered on the system; and

•	In addition to all NERC standards developed and implemented by NERC/SERC, utilities must
also satisfy planning reserve margin requirements established by NERC/SERC, as well as
resource adequacy expectations established by state public utility regulators.

Comment 14: Commenter 17731 questions the EPA's view that utilities can easily retire and replace
units that are unable to comply with the new emission limits. The commenter considers the option of
replacing older units with more efficient units to be risky because they utility may spend the time and
money to build new coal-fired units only to find out that the units cannot comply with the stringent new
unit emission limits.

Response to Comments 8-14: The EPA agrees with these commenters that real threats to reliability
from these rules are unlikely but agrees as well that a process involving early notification can promote
confidence in reliability and as well as promote the kind of planning by companies, regulatory agencies,
grid operators, and reliability organizations that can ensure a smooth transition to cleaner electric
generating fleet.

The industry has adequate resources to install the necessary controls and develop the new capacity that
may be required within the compliance time provided for in the final rule.3 The EPA believes that the
flexibility of permitting authorities to allow a fourth year for compliance should be available in a broad
range of situations (as discussed in the preamble), and that this flexibility addresses many of the
concerns that have been raised. Furthermore as indicated below, in the event that an isolated, localized
concern were to emerge that could not be addressed solely through the 1-year extension under CAA
section 112(i)(3), the CAA provides flexibilities to bring sources into compliance while maintaining
reliability.

Although there are a significant number of controls that need to be installed across the industry, with
proper planning, we believe that the compliance schedule established by the CAA can be met. Many
companies have begun to do the detailed analysis and engineering and are ahead of others in their
compliance strategy. There are already tools in place (such as integrated resource planning, and in some
cases, forward auctions for future generating capacity) that ensure that companies adequately plan for,
and markets are responsive to, future requirements such as this final rule.

The EPA agrees with these commenters that if companies that intend to retire EGUs formally notify
their RTO (or comparable planning coordinator in the case of non-RTO regions), state regulatory

3 As stated above, EPA has provided the maximum compliance time authorized under CAA section
112(i)(3)(A).

294


-------
agencies, and regional reliability entities as soon as possible that they will retire, it would help to
alleviate any local reliability concerns.. As we said before, in most places a closing plant will not be a
cause for concern. To the extent there is concern, however, early notification will provide an opportunity
for transmission planners, market participants, and state authorities to develop solutions to avoid a
reliability problem. In RTOs with forward capacity markets, owner/operators that do not bid generating
capacity that they plan to close will provide an advance signal to market participants to take action to
assure adequate future capacity. In all regions, early and public notification will allow market
participants, planning coordinators and state authorities, as appropriate and in a timely fashion, to bring
new generation on line, put demand side resources in place, and/or complete any transmission upgrades
needed to circumvent a potential issue. Most RTOs only require 45 to 120 days notification of closure.
The 5 RTOs suggested that such notification should be made no later than 12 months after this
regulation is final in order to allow a smooth transitioning to action to avoid a reliability problem. The
EPA strongly encourages early notification, and believes that responsible owner/operators should and
will do the early planning for compliance and provide early notification of their compliance plans,
especially where such plans include retiring one or more units.

On the supply side, there are a range of options including the development of more centralized power
resources (either base-load or peaking) and/or the development of cogeneration or distributed
generation. Even with the current large reserve margins, there are companies ready to implement supply
side projects quickly. For instance, in the PJM region, there are over 11,600 MW of capacity that have
completed feasibility and impact studies and could be on-line by the third quarter of 2014.4 The EPA
notes, as well, that in the 3 years from 2001 to 2003, industry brought over 160 GW of generation on
line.5

Demand side options include energy efficiency as well as demand response programs. These types of
resources can also be developed very quickly. In 2006, PJM had less than 2,000 MWs of capacity in
demand side resources. Within 4 years this capacity nearly quadrupled to almost 8,000 MW of capacity.6
In addition to helping address reliability concerns, reducing demand through mechanisms such as energy
efficiency and demand side management practices has many other benefits. It can reduce the cost of
compliance and has collateral air quality benefits by reducing emissions in periods where there are peak
air quality concerns.

With regard to transmission, recent experience also shows that, in many cases, transmission upgrades to
address reliability issues from plant closures can be implemented in less than 3 years. For instance, when
Exelon notified PJM of its intention to retire four units,7 it was determined that transmission upgrades
necessary to allow retirement of two units could be made within 6 months of notification, transmission

4	Paul M Sotkiewicz, PJM Interconnection, Presentation at the Bipartisan Policy Commission Workshop
Series on Environmental Regulation and Electric System Reliability, Workshop 3: Local, State,

Regional and Federal Solutions, January 19, 2011, Washington DC,

http://www.bipartisanpolicv.org/sites/default/files/Paul%20Sotkiewicz-%20Panel%202 O.pdf slide 6

5	National Electric Energy Data System (NEEDS 4.10) (EPA, December 2010)

6	BPC slides cited above - slide 5

7	http://www.exeloncorp.com/Newsroom/pages/pr_20091202_Generation.aspx?k=eddystone

295


-------
upgrades for the third unit would require slightly over 1 year and transmission upgrades to allow the
fourth unit to retire could be made in approximately 18 months.8

The CAA allows CAA Title V permitting authorities the discretion to grant extensions to the compliance
time of up to one year if needed for installation of controls. See CAA section 112(i)(3)(B)). If an
existing source is unable, despite best efforts, to comply within 3 years, a permitting authority has the
discretion to grant such a source up to a 1-year extension, on a case-by-case basis, if such additional
time is warranted. This provision applies to all NESHAP. See 40 CFR 63.6(i)(4)(i). We believe that the
permitting authorities have the discretion to use this extension authority to address a range of situations
in which installation schedules may take more than 3 years.

The EPA does not believe there will be a significant impact on oil facilities as a result of the final rule.
The rule contains "limited use" provisions that will mitigate the impacts on many oil-fired facilities used
for peaking and/or reliability purposes. For those units that are expected to continue firing residual oil,
many already have existing air pollution control technologies (e.g., electrostatic precipitators) necessary
to achieve the emission standards and the remaining units that are not capable of converting to another
fuel (e.g., subject to natural gas curtailment) are expected to install cost-effective air pollution control
technologies. The EPA used AEO demand forecasts as the baseline for electricity demand. The EPA
does not believe these forecasts overstate the impact of energy efficiency. The EPA used the official
target reserve margins that were available at the time of the analysis of the final rule in the 2010 Long
Term Assessment. In the case of ERCOT, the reserve margin was 12.5% percent in that assessment, but
was updated after the margins were provided to NERC for the 2010 Long Term Assessment. The EPA's
IPM modeling of MATS shows that ERCOT would continue to meet its target reserve margin even
taking into account its recently revised target of 13.75 percent. See TSD on Resource Adequacy for EPA
resource adequacy results. The EPA believes the regional impact evaluation that it conducted was
correct in focusing resource evaluation at the regional level, and treating local reliability issues within
regions as best handled by standard reliability management practices as the rule is implemented.
Processes for addressing local reliability issues have been made more flexible in response to comments
received on the proposed rule and are discussed in the preamble. See also responses elsewhere on local
reliability issues. As the commenter notes, ERCOT reserve margins are above their target margin in
2012. The EPA agrees with the commenter's recognition that ERCOT's projected capacity shortage
shown in that report is not primarily driven by EPA regulations. The EPA believes that there will be
sufficient time to add more capacity where needed in ERCOT by 2015; EPA has also included
additional flexibility on timing of compliance in the final rule. The EPA's IPM modeling does not
purport to capture all potential local reliability variables affecting any specific unit. The final rule
provides greater flexibility when additional time is needed to address transmission issues arising from
reliability violations related to plant retirements. As noted earlier, the EPA modeled demand based on
the AEO, which includes an estimated level of demand response. The reliability contribution from
renewable resources is a relevant issue only for wind resources. The reliability capacity contribution
from wind resources in the analysis of the rule was based on estimates from the National Renewable
Energy Laboratory (NREL) and was incorporated in the resource adequacy assessment (See IPM
documentation of wind resource and TSD on Resource Adequacy.) Local reliability issues can be
addressed during implementation of MATS.

Cromby Units 1 and 2 and Eddy stone Units 1 and 2 - Deactivation Study, Updated September 7, 2010
- http://policyintegrity.org/documents/20100907-cromby-and-eddystone-retirement-study-posting-
update.pdf

296


-------
Comment 15: Commenter 17725 asks that the compliance date align with the Power Year used by
RTOs.

Response to Comment 15: The compliance date for existing sources subject to this rule is 3 years from
this rule's effective date. That is the maximum amount of time permissible under CAA section
112(i)(3)(B) which the EPA felt appropriate given the significant work that some plants will need to
undertake to come into compliance.

Comment 16: Commenter 17821 asks that the EPA develop guidance on applicability of section
112(i)(6) in the final rulemaking.

Response to Comment 16: There are regulatory provisions in 40 C.F.R. section 63.6 (the general
provisions) that govern the use of CAA section 112(i)(6).

Comment 17: Commenter (17887) supports the provision in the NARUC resolution that the rule should
allow sufficient time for generators to evaluate and implement the best compliance options and integrate
these options into their systems in order to ensure reliability of operations.

Response to Comment 17: The EPA has consistently said that early planning for compliance is very
important and we have urged utilities to take proactive steps in coordination with relevant planning and
regulatory authorities. The industry has adequate resources to install the necessary controls and develop
the new capacity that may be required within the compliance time provided for in the final rule.9
Although there are a significant number of controls that need to be installed across the industry, with
proper planning, we believe that the compliance schedule established by the CAA can be met. Many
companies have begun to do the detailed analysis and engineering and are ahead of others in their
compliance strategy. There are already tools in place (such as integrated resource planning, and in some
cases, forward auctions for future generating capacity) that ensure that companies adequately plan for,
and markets are responsive to, future requirements such as this final rule.

Commenter 18: Commenter 17701 representing the National Association of Regulatory Utility
Commissioners (NARUC) states that although there are logistical issues that may impact system
reliability given the Proposed Rule's compliance timeframe such as: coordination of offline time for the
installation of pollution controls on several plants in the same region; repowering or replacing a plant
with a natural gas generator relies on access to natural gas pipelines; and transmission solutions
generally take longer to plan, site, build and interconnect than the proposed rule's 3- to 4-year
compliance timeframe, the association's members will work with their utilities to ensure that customers
maintain access to safe and reliable power while generating plants install controls or while plants are
retired and replaced or repowered.

Response to Comment 18: The EPA appreciates this comment and agrees that the state regulators have
an important role to play in assuring that the transition to a cleaner electric generating fleet that this rule
will bring about occurs as smoothly as possible so that reliable power is maintained.

Comment 19: Commenter 17701 advocates flexibility in the implementation of this and other rules to
avoid compromising electric system reliability while minimizing cost impacts to consumers. According

9 As stated above, EPA has provided the maximum compliance time authorized under CAA section
112(i)(3)(A).

297


-------
to the commenter, flexibility will enable the EPA to accommodate the highly localized and regional
nature of electricity services and avoid reliability issues.

Comment 20: Commenters 17701 and 17791 suggest the EPA allow utilities (1) to coordinate the
closure and/or retrofitting of existing electric generating units in an orderly manner that will ensure the
continued supply of electricity; (2) allow regulatory options for units that are necessary for grid
reliability that commit to retire or repower; (3) allow an EPA-directed phasing-in of the regulation; and
(4) establish interim progress standards that ensure generation units meet the EPA regulations in an
orderly, cost-effective manner.

Comment 21: Several commenters (17701, 17761, 17791, 17930, 19506, 19114) advocate flexibility in
the implementation of the EGU MACT and other rules to avoid compromising the reliability of the
electric system. These commenters believe the EPA should incorporate greater flexibility into the EGU
MACT to ensure adverse impacts on the reliability of the electricity supply are avoided.

Response to Comments 19-21: There are several flexibilities in final rule that EPA wills help to avoid
reliability issues. The regulation is applied facility wide so that facilities are able to average across units.
Facilities also are able to average over time. They do not have to operate above the standard all the time
but rather can meet the standard on a 30 day rolling average. There are alternative standard formats so
that a plant can choose, for example, to meet a metals standard or a PM standard on either an input or
output based level. In addition EPA is encouraging that permitting agencies be generous in offering the
fourth year for installation of controls.

Comment 22: Commenter 17701 encourages the EPA to work with state and federal environmental
regulators to examine all possible options to maintain system reliability and achieve health and
environmental benefits while also ensuring reliability, minimizing capital costs to utilities, rate increases
to consumers, and other avoidable economic impacts. The commenter offers the following suggestions:

Allow utilities to coordinate the closure and/or retrofitting of existing electric generating units in
an orderly manner that will ensure the continued supply of electricity and that will allow power
generators to upgrade their facilities in the most cost effective way, while at the same time
achieving attainable efficiency gains and environmental compliance; and

Allow regulatory options for units that are necessary for grid reliability that commit to retire or
repower; and

Allow an EPA-directed phasing-in of the regulation requirements; and

Establish interim progress standards that ensure generation units meet EPA regulations in an
orderly, cost-effective manner.

Commenter 23: Commenters 18441 and 18448 request that the EPA state in the preamble to the final
rule that the permitting authority should explicitly authorize or endorse the extensions to the 3 year
compliance deadline for units which the RTO or relevant Reliability Coordinator indicates are
"Reliability Critical Units." Commenter 18441 believes that Reliability Critical Units that have timely
announced their deactivation should be eligible for a 1-year extension of the compliance obligation
because deactivating a generating unit is simply another control option to comply with the final rule if
the affected generating unit owner believes this is the least-cost compliance option, and is effectively no
different from a generating unit choosing to install retrofits to meet the emissions rate standards that

298


-------
cannot get its retrofits in service by the January 1, 2015, compliance deadline. The commenter suggests
that units choosing deactivation as a compliance option would only be granted an exemption if under the
RTO's independent analysis, they are deemed critical to system reliability and are required to stay in
service for a defined period until transmission or replacement resource solutions could be placed into
service.

Response to Comments 22-23: The EPA expects that the fourth year for compliance will be broadly
available to these plants that need it for the installation of controls or on site replacement capacity or,
where reliability could be at risk, for transmission upgrades and construction of replacement capacity off
site. This will allow facilities to plan for a well-coordinated compliance period.

Comment 24: Commenter 17868 desires that EPA take into account the numerous contingencies that
could cause concern for reliability during the compliance period including multiple retirements, multiple
outages, lack of generator response during a cold weather event, and revisions to the North American
Electric Reliability Corporation's (NERC) Critical Infrastructure Protection (CIP) Standards.

Response to Comment 24: The EPA has indeed taken into account the wide array of contingencies that
will prevent a facility from either retrofitting or closing within the compliance time frame. The EPA
maintain that most, if not all, units will be able to comply with the requirements of this rule within 3
years. The EPA also believes that making it clear that permitting authorities have the authority to grant a
1-year compliance extension where necessary, in the range of situations described above, addresses
many of the other concerns that commenters have raised. The EPA believes that the number of cases in
which a unit is reliability critical and in which it is not possible to either install controls on the unit or
mitigate the reliability issue through construction of new generation, transmission upgrades, or demand-
side measures, within 4 years, is likely to be very small or nonexistent. None-the-less, where such cases
appear EPA has authorities to manage these situations so that the maximum environmental protection
can be achieved while facilities continue to come into compliance.

Comment 25: Commenter 17919 claims that analyses that have been submitted to the EPA showing
that the rule does not cause a problem for electricity reliability, are "highly suspect" in that they are
"largely from economic competitors with a vested economic interest in decreasing the economic
viability of coal-fired generation and thereby increasing the clearing price of energy for consumers -
that dispute adverse reliability claims from the proposed rule."

This commenter points instead to another analysis from the Federal Energy Regulatory estimating a
large amount of coal-fired capacity 'likely' and "very likely" to retire. The commenter states that the
EPA should utilize the flexibility afforded under the CAA to ease the compliance schedule set out by the
proposed rule.

Response to Comment 25: The EPA makes no judgments about the motives of any of the commenters.
The Federal Energy Regulatory Commission (FERC) report relied on here was a staff draft that was
done before EPA had even proposed its regulations. It made assumptions about the stringency of the
regulations that went well beyond what EPA actually proposed and final led. As such it has very little
bearing on this rulemaking. Furthermore the FERC Chairman stated clearly that the study the
commenter is referring to was a "back-of-the envelope first assessment of the amount and location of
potential generator retirements. He further said that informal assessment of that kind cannot be relied
upon to determine specific effects on system reliability. Therefore, it is inadequate to use as a basis for
decision making."

299


-------
None-the-less as stated elsewhere in this document, the CAA provides flexibility to address any
reliability problems should any arise.

2. Current compliance period should be shorter.

Comment 26: Several commenters (15678, 16122, and 17846) ask the EPA to ensure that compliance
occurs as soon as possible. Commenters 16122 and 17846 make note of the EPA's Trust Responsibility.

Comment 27: Commenter 17819 asserts that the 3 or 4 year implementation schedule for Hg control is
not as expeditious as practicable. According to the commenter:

1.	U.S. EPA asserted in 2000 that is appropriate and necessary to establish Hg emission standards for
coal-fired EGUs. 65 FR 79825 (December 20, 2000).

2.	By 2003, the DOE concluded ACI is an effective Hg control technology for coal-fired EGUs that
requires minimal capital costs, is easily retrofitted and can achieve 90 percent removal efficiencies. See
Durham, Michael et al. Full-Scale Evaluation of Mercury Control By Injecting Activated

Carbon Upstream of ESPS. 2003. available at:

www.netl.doe.gov/technologies/coalpower/ewr/mercury/control-tech/pubs/ A5-B2.pdf.

3.	The DOE's findings about the effectiveness of ACI Hg control systems are consistent with the use of
ACI in other industry sectors since the mid-1990's to meet MACT mandates. See 62 FR 48348
(September 15, 1997).

4.	Coal-fired EGUs in Illinois and several other states are already subject to state-specific Hg emission
standards and have demonstrated it is already practicable to retrofit effective Hg controls. See "State
Local Mercury Toxics Program for Utilities" from the NACAA, available at Www.4cleanair.org; see
also 35 111. Admin. Code § 225.230.

5.	For its part, U.S. EPA's present regulatory proposal explicitly acknowledges that all Hg control
options take significantly less than 3 years to install. Proposed Rule at 441-447.

6.	U.S. EPA also estimates that the implementation of these controls will reduce cumulative Hg
emissions from 29 tpy to 6 tpy. Id at 26 and 153. Each year that regulatory implementation is delayed
will result in up to 23 tons of unnecessary emissions of Hg, a persistent, bioaccumulative and toxic
substance.

7.	In light of the ready availability of Hg controls for coal-fired EGUs and the well established threat to
human health and the environment posed by Hg emissions, U.S. EPA's compliance timeline is not as
expeditious as practicable.

8.	To comply with the CAA mandate for emission standards to be implemented as expeditiously as
practicable, two commenters assert U.S. EPA must establish a more immediate deadline for
implementation of Hg emission standards for coal-fired EGUs.

9.	Under any circumstances, it is contrary to the plain language of the CAA and against the manifest
weight of evidence to allow a 4-year compliance schedule for any coal-fired EGU.

300


-------
On the other hand, commenter 17675 requests a 5-year compliance period for the Hg limits only. The
commenter notes that this would be similar to the BACT status allowed under 40 CFR 63.6(i)(2)(ii).

Response to Comments 26 and 27: Several commenters suggested that 3 years was too long for a
compliance period given the delays in promulgating this regulation, and urged EPA to require
compliance in a shorter timeframe. Some of these commenters said that, consistent with EPA's Trust
Responsibility the compliance period should be as short as possible. The EPA understands very well the
importance of bringing facilities into compliance as soon as possible so that all Americans can realize
the public health benefits of this rule without further delay. We agree that many plants will need fewer
than 3 years to come into compliance and some already are in compliance. For other plants, coming into
compliance will require substantial engineering and construction. The EPA finalized the 3-year
compliance period for EGUs given the sheer number of sources that are in the category and that may
have to install controls to comply with the final rule.

3. Current compliance dates are sufficient.

Comment 28: Multiple commenters (19536, 19537, 19538, 17110, 17402, 17648, 17808, 17854, 17870,
17973, 18025, 18027, 18421, 18425, 18438, 18439, 18450, 18487, 18501, 18541) ask that no additional
time be granted for compliance.

Multiple commenters (19536, 19537, 19538, 16850, 17408, 17421, 17648) reference an April 2011
report entitled "Assessment of Technology Options Available to Achieve Reductions of Hazardous Air
Pollutants" where URS Corporation concludes not only that technology is readily available, but that the
technology can typically be installed in less than 2 years.

Commenter 18421 states that based on that report, no additional controls would need to be installed in
many cases and any coal unit should be able to comply with all of the standards. Commenter 17648
notes that utilities that failed to plan ahead "should not be permitted to use their own inaction to justify
more time."

Commenters 17808 and 18450 note that several major utility companies have anticipated the EPA's
rules and are already taking action to ensure a reliable supply of electricity in their service territory and
beyond. Commenter 17808 cites two companies that have made planning efforts in advance of final
rulemakings. The commenter cites one company (NextEra Energy) that began evaluating control
technology before the release of the proposed rule. The commenter cites another company (Constellation
Energy) that similarly conducted preliminary engineering studies before the Maryland Legislature
enacted the Healthy Air Act of 2006.

Commenters 17648 and 18450 agree that there is significant excess generation capacity in the country
and reliability will not be threatened by the rule.

Several commenters (18487, 19536, 19537, 19538) agree that the 3-year period will not adversely affect
electricity system reliability.

Commenter 17110 urges the EPA to proceed with finalizing the rule without delay. According to the
commenter, companies are already preparing for a 2015 compliance date, factoring in the capital
expenditures required to comply and delays would undermine decisions that have already been made.

301


-------
Commenters 17789 and 18450 agree that the compliance time is reasonable and further states that a
shortage of skilled labor is unlikely to prevent utilities from meeting the compliance requirements.

Commenter 18421 notes that the Building and Construction Division of the AFL-CIO has stated that
there is no evidence to suggest that the availability of skilled manpower will constrain pollution control
technology development. According to the commenter, in fact, given the high levels of unemployment
in the construction sector, these jobs are much needed.

Several commenters (17844, 18439, 18450) believe that the industry is well-positioned to comply in the
time allotted without threatening electric system reliability. Commenters (17844, 18450) cite the
following sources: two recent reports - one from M.J. Bradley & Associates and Susan Tierney of the
Analysis Group, and the other from the Bipartisan Policy Center - that independently conclude that the
electric industry is well-positioned to comply with the EPA's proposed air regulations without
threatening electric system reliability. According to the commenters, if electric system reliability were to
be threatened in local areas as a result of the rule, the EPA has the statutory authority to grant, on a case-
by-case basis, extensions of time to complete the installation of pollution control systems.

The commenters assert that in addition, recent electricity forward capacity market auctions in the PJM
and ISO-New England markets for the period of 2014 and 2015 indicate that the capacity markets
cleared with electricity reserve margins of 20 percent in PJM and greater than 14.4 percent in ISO-New
England. According to the commenters, these reserve margins are well in excess of the federal reliability
standards set by the NERC for the year 2015, and these results cover periods after the rule is expected to
have been in place for at least 6 months, demonstrating that the electric industry can meet the
requirements of the rule without threatening the reliability of the electric system. Commenter 18450
quotes NERC, stating that NERC does not see impacts from the proposed climate legislations or
anticipated EPA regulation as a reliability concern. Commenter 18450 cites a January 2011 report by
Charles Rivers Associates (CRA) that concludes that (1) Less than 5 percent (35 GW) of the total
capacity in the EIC will retire by 2015; and (2) Electric system reliability can be maintained while
transitioning to a cleaner energy future through increasing operation of existing, underutilized gas
plants, coal-to-gas conversions, new gas-fired generation, expansion of load management programs, and
established market and regulatory safeguards.

Commenter 18541 notes the existence of a:

broad array of electricity generation and grid management technologies that are making
"baseload" power obsolete as FERC Chairman Wellinghoff noted in 2009. Indeed, a
combination of renewable energy (such as wind, solar, biomass, geothermal, low-head
hydro), natural gas and flexible generation technologies, and energy efficiency can now
meet new electricity demand, and begin to replace or back out existing generation, within
most balancing areas in the country. Such combinations of technologies, paired with
smart grid management in balancing areas (including use of forecasting of output from
wind and sun generation) can ensure a reliable electricity supply. The use of renewable
energy and efficiency will also provide savings over time from reduced fuel use.

Commenter 17819 cites a 2003 DOE report evaluating Hg control by activated carbon:

injection (ACI), stating that ACI has low cast, requires little downtime to install, is
effective for bituminous and sub bituminous coals, can achieve 90 percent removal when

302


-------
used with a fabric filter, can be integrated with virtually every configuration of air
pollution control equipment including ESPs, fabric filters, wet and dry scrubbers.

Commenter 18425 states that the 1-year extension if the facility is unable to install appropriate controls
will protect electricity system reliability. According to the commenter, applying the extension to both
the installation of add-on controls and the construction of on-site replacement power is appropriate
under the CAA.

Commenter 17928 supports the schedule and the agency's authority to extend the time allowed provided
that any additional time granted does not provide an undue economic advantage.

Comment 29: Commenter 17648 asked that EPA establish uniform criteria for the section 112(i)(3)(B)
case-by-case one-year extension and allow plants that receive the extension to dispatch only to meet
reliability needs during the extension period.

Comment 30: Multiple commenters (17254, 17620, 17648, 17810, 17852, 17853, 18025, 18421,
18932) agree with the EPA's assessment that the new rules will not jeopardize or impair the reliability
of the electricity supply. Other commenters (17254, 17648, 17810, 17852, 17853) cite reliability
assessments that show sufficient capacity to ensure reliability of the electricity network after the rule
takes effect. These include:

•	North American Electric Reliability Corporation (NERC). 2010 Long-Term Reliability
Assessment. October 2010. http://www.nerc.com/files/2010_LTRA_v2-.pdf

•	Ira Shavel & Barclay Gibbs, Charles River Associates, "A Reliability Assessment of EPA's
Proposed Transport Rule and Forthcoming Utility MACT" (Dec. 16, 2010)

•	Michael J. Bradley, Christopher E. Van Atten, & Amlan Saha (M.J. Bradley & Associates LLC)
& Susan F. Tierney (Analysis Group), "Ensuring a Clean, Modern Electric Generating Fleet
while Maintaining Electric System Reliability: Summer 2011 Update," (June 2011)

•	Susan F. Tierney & Charles Cicchetti, "The Results in Context: A Peer Review of EEI's
'Potential Impacts of Environmental Regulation on the U.S. Generation Fleet'" (May 2011).

•	Integrated Planning Model data commissioned by America's Natural Gas Alliance (ANGA).

•	Credit Suisse, Growth from Subtraction: Impact of EPA Rules on Power Markets (September 23,
2010), p. 45, available at

http://epw. senate.gov/public/index.cfm?FuseAction=Files. View&FileStore_id=b42de70d~
-b814—4410—83 Id— 34bl80846al9.

Comment 31: Several commenters (17648, 17853, 18421) believe that the number of coal-fired EGU
retirements that will result of regulation of EGUs have been overestimated by some sources. These
commenters note that independent analyses support the EPA's retirement projections, and criticisms of
the EPA's projections are overstated. Commenters note that EEI's report resulted in inflated unplanned
coal retirements because their modeling scenarios incorrectly assumed that the Waxman-Markey climate
change bill passed Congress, that the CWA section 316 cooling tower regulations would mandate a one-
size-fits-all standard, and MACT limits that are more restrictive than those proposed in the Toxics Rule.
Commenters also state that the Tierney-Cicchetti Peer Review Report found that only one of EEI's
scenarios represented a plausible regulatory scenario, but determined that the incremental unplanned
coal retirements modeled under this scenario for 2015 (totaling 24 GW) should be considered the upper
end of potential retirement impacts, since even this scenario overstates the impacts of the section 316
rule. Commenter 18421 believes that the North American Electric Reliability Corporation (NERC)

303


-------
"2010 Special Reliability Assessment: Resource Adequacy Impacts of Potential U.S. Environmental
Regulations" may also overestimate the impact of new regulations.

Comment 32: Several commenters (17648, 17810, 17852) believe that existing gas units have
significant untapped potential, which can be utilized to maintain reliability without the need to undertake
new construction. Commenter 17648 notes that if all coal-fired units with a name plate capacity of less
than 200 MW retired, the power produced by these retired units could be replaced using only 5% of the
unused capacity of existing combined cycle gas units. Commenter 17810 notes that the existing natural
gas-fired EGU capacity will allow the industry to maintain its reserve margins, including during the
scheduled outages that will be necessary to install pollution control equipment required by this
regulation.

Comment 33: Several commenters (17620, 17648, 17853, 17875, 18932) argue thatEGUs will have
sufficient time to comply with the rule without disrupting reliability. These commenters note that power
plants have known about the various new regulations affecting power plants for several years and have
therefore had plenty of time to prepare. These commenters note that many public utility commissions
require integrated resources plans, which implement a planning mechanism to assure adequate reserve
margins are maintained. Commenter 18932 notes that several utilities have made statements indicating
that they are well positioned to comply with the EGU MACT, as well as other EPA regulations that will
affect the utility sector.

Comment 34: Commenter 17620 points out that several states have implemented Hg limitations for
EGUs without adverse impacts on reliability.

Comment 35: Several commenters (17110, 17810, 18025, 18421) note that forward capacity auctions,
such as those held by PJM and ISO-New England for the years 2014 and 2015 (after the Transport Rule
and this proposed rule will be in effect), have shown that the regions will have more than enough
capacity to meet federal reliability standards without significant price increases.

Comment 36: Several commenters (17648, 17810, 17853, 18025) believe that retirements that occur
can be managed and new capacity can be developed to ensure no disruption to the electric power supply
after the rule is implemented. These commenters note that a number of practical and legal options exist
for when an EGU is to be retired or needs greater time to install controls. Commenters further note that a
resolution that maintains reliability can be reached through the authority under the Federal Power Act, or
through exercise of enforcement discretion in a consent order to decree that accommodates both
environmental imperatives and reliability concerns. Commenter 17648 points out that if reliable electric
power is compromised by compliance with environmental regulations, the U.S. DOE, the EPA, state
agencies, and regional transmission organizations (RTOs) can work together to strike a balance in
protecting public interest in both objectives. Commenter 17648 also notes that RTOs typically have
advanced warning of proposed unit retirements and that each RTO has procedures to assure that threats
to reliability are identified early enough to be avoided.

Comment 37: Commenter 17810 notes that the EPA can grant time extensions for power plants to
install pollution control equipment on a case-by-case basis under the CAA. This commenter further
notes that the EPA and the DOE have the authority to enter into administrative orders of consent or
consent decrees with power plants that allow them to run under specific and limited circumstances to
maintain reliability. The commenter states that the DOE can override CAA requirements under section
202(c) of the Federal Power Act in limited emergency circumstances, and if a widespread reliability
concern were to arise that could not be addressed through these statutory mechanisms, the President also

304


-------
has the authority under the CAA to extend deadlines in the rule if technologies are not available and it is
in the national security interest.

Comment 38: Commenter 18039 questions the suggestion that existing units be allowed to run for an
additional year while a replacement is constructed, without being subject to MACT standards for that
year. The commenter agrees that this is a reasonable scenario for facilities that will use that year to
construct a replacement unit with significant long-term emission reductions. However, the commenter is
concerned that a facility in the process of building replacement power may decide to operate a high-
emitting unit for an additional year, specifically due to the extension. The commenter therefore objects
to the extension, for fear a large amount of pollutants will result. The commenter also asks that if
construction replacement power lasts longer than the one-year extension, the final rule wording make
clear that the older unit is not permitted to avoid MACT compliance beyond that year, even if the
replacement is not yet on-line.

Comment 39: Commenter 18421 called on the EPA, the Department of Energy, and the Federal Energy
Regulatory Commission to expand and accelerate interaction with regional utility planning and
operation centers, the National Association of Regulatory Utility Commissions, state PUCs, and
all market participants to ensure that the measures available to preserve electric system reliability while
providing for life-saving reductions of Air Toxics are implemented.

Commenter 19114 states that EPA notes that before the final rule, they will work with "DOE and FERC
to identify any opportunities offered by the authorities and policy tools at the disposal of DOE and/or
FERC" to protect reliability. According to the commenter, this language suggests that EPA has not
consulted with DOE and FERC to date, which suggests that the necessary rule coordination or
harmonization is not occurring. The commenter states that the statement implies that EPA only sees
flexibility on the part of DOE and FERC to protect reliability and that adding this flexibility into the
MACT rule itself, or other proposed rules for that matter, is not a concern for EPA, which goes directly
against the Executive Order.

The commenter states that it has been involved in a series of meetings with PJM, SPP, EPA, DOE,
FERC, and NERC to discuss the impacts of this and other EPA rulemakings on the reliability of the
transmission system as well as to discuss ways that EPA can provide flexibility to ensure reliability. The
commenter suggests that EPA closely examine all of the publicly announced implementation plans from
utilities to assess the accuracy of the data EPA is relying on to make the claim that grid reliability is not
an issue. According to the commenter, these data must take into account actual and planned future
regulations and their impact on the electric sector, as well as resulting rate and reliability impacts, and
only in viewing a comprehensive and holistic analysis of the electric sector can there be a reasonable
discussion of the reliability impacts. The commenter states that this type of cross-functional analysis
should include the most specific localized or unit level reliability analysis possible in order to pick up
key ancillary services important to grid stability.

Response to Comment 28 - 39: The EPA has set out in the preamble to this rule, the situations that
merit the one-year extension under CAA section 112(i)(3)(B). While authority to grant the 1-year
extension is given to the state permitting authorities, EPA expects that that discussion in the preamble
will help guide the states on this matter.

While the ultimate discretion to provide a 1-year extension lies with the permitting authority, EPA
believes that when appropriate it will be broadly available to facilities. Please see the preamble for a
fuller discussion of the 1-year extension.

305


-------
4. Current compliance period should be longer.

Comment 40: Numerous commenters (18023, 8443, 9738,

17254, 17265, 17297, 17368, 17383, 17400, 17402, 17403,

17640, 17648, 17654, 17655, 17656, 17675, 17677, 17681,

17711, 17714, 17716, 17720, 17722, 17724, 17730, 17731,

17756, 17758, 17761, 17765, 17767, 17770, 17774, 17775,

17808, 17810, 17812, 17813, 17815, 17817, 17820, 17821,

17868, 17870, 17873, 17876, 17877, 17878, 17879, 17881,

17911, 17912, 17913, 17918, 17925, 17930, 17931, 18016,

18038, 18419, 18422, 18424, 18428, 18430, 18433, 18437,

18502, 18575, 18933, 19032, 19114, 19121, 19212, 19213,
period is too short.

Several commenters (8443, 9738, 17608) ask that small entities be granted additional compliance time.

Multiple commenters (16469, 16705, 16849, 17265, 17400, 17637, 17655, 17656, 17703, 17730, 17758,
17776, 17913, 18038, 18437, 18447, 18477, 18498) advocate for an optional extension for 2 more years,
resulting in a total of 5 years. Several commenters (18575, 19032, 19213) request that the EPA allow a
total of 5 years for compliance.

Multiple commenters (18023, 17623, 17689, 17714, 17722, 17731, 17732, 17756, 17775, 17817 (major
sources of HAP), 17868, 17904, 17925) request that the EPA allow a total of 6 years for compliance.

Multiple commenters (17022, 17408, 17735, 17758, 17761, 17817 (non-major sources of HAP)) ask that
the timeframe be extended until 2020.

Several commenters (17724, 17741, 17805, 17868) ask that a compliance timeline of 9 years be
permitted.

Multiple commenters (17055, 17408, 17677, 17734, 17756, 17761, 17774, 17791, 18024, 18026, 18422,
19506) ask that the EPA consider a flexible, gradual, or staggered compliance schedule for this
rulemaking.

Commenter 17911 requests a 2-year extension on compliance with some provision for further extension
for local utilities, based on the utilities' additional burden of maintaining a publicly accountable process.
The commenter requests provision for further extension provided that the local utility can document that
they have pursued a good faith effort to expeditiously secure approvals, financing, engineering, design,
manufacturing, acquisition and installation of the necessary emission control equipment.

Commenter 18441 states that outage windows to accommodate upgrade construction are limited to
opportunities when prevailing system conditions permit, so that operational reliability is not
compromised. The commenter appreciates the EPA's recognition of the need to spread complex outages
over multiple outage periods. According to the commenter, as the breadth of the outages and the
availability of retrofit materials may impact the scheduling of outages, it is not clear that the proposed
3+1 timeline provides sufficient flexibility for the commenter, as a regional transmission organization to
manage all of these outages in a staggered manner.

16705, 16469, 16849, 16856, 17022, 17055,
17406, 17608, 17623, 17627, 17637, 17638,
17689, 17696, 17697, 17703, 17705, 17707,
17732, 17734, 17735, 17736, 17741, 17752,
17790, 17798, 17799, 17800, 17805, 17807,
17824, 17829, 17834, 17837, 17840, 17857,
17883, 17885, 17887, 17902, 17904, 17909,
18021, 18024, 18026, 18027, 18031, 18037,
18440, 18441, 18447, 18477, 18498, 18500,
19506, 19653) state that the compliance

306


-------
Commenters 18441 and 18448 state that timely notice of deactivation to the regional transmission
organization and an identification that the unit in question is a reliability critical unit which cannot be
replaced with alternative resources or transmission reinforcements in the 4-year time allotted would be
allowed a limited "safe harbor" from penalties until the regional transmission organization indicates that
adequate resources have been put in place to address the reliability concern. The commenter states that
the regional transmission organization's findings would be developed in open stakeholder processes and
made available for the EPA's (or state air permitting authority's) ultimate determination as to whether to
grant such an extension and that such a process may entail the EPA authorizing or endorsing a schedule
of compliance in the affected generating unit's Title V permit through the implementing state authority,
in coordination with the regional transmission organization; and/or a Consent Decree between the EPA,
the state authority and the generation owner developed and signed prior to the end of the compliance
period, or a formal extension through a streamlined process including the EPA, and the implementing
state authority working with the asset owner and the regional transmission organization to grant
extensions beyond January 1, 2016.

Multiple commenters (16469, 16850, 17608, 17640, 17705, 17711, 17716, 17719, 17724, 17730, 17752,
17756, 17761, 17774, 17805, 17820, 17821, 17837, 17840, 17868, 17902, 17918, 17919, 17931, 18016,
18033, 18037, 18422, 18428, 18440, 18442, 18498, 18575, 19506) ask that the EPA consider other
simultaneous rulemakings and extend the compliance period. Commenters specifically mentioned the
following:

a.	Cooling Tower Intake Structures (17724, 17805, 17868, 17918, 17919, 18440, 18442)

b.	Coal Combustion Residuals (17724, 17774, 17805, 17821, 17868, 17918, 17919, 18440, 18442)

c.	Regional Haze (17719, 17724, 17730, 17761, 17805, 18442)

d.	Clean Air Transport Rule (17608, 17724, 17868)

e.	Water Effluent Limit Reductions (17724, 17774, 17805, 17919)

f.	Cross State Air Pollution Rule (16850, 17640, 17705, 17716, 17730, 17752, 17756, 17761, 17774,
17820, 17821, 18442, 18498, 19506)

g.	NESHAP for industrial, commercial and institutional boilers (16469, 17608, 17711,

17756, 17837, 17840, 18024, 18424, 18442)

h.	NESHAP for commercial and industrial solid waste incinerators (17608, 18024)

i.NSPS	for greenhouse gas emissions from EGUs (17608, 17774, 17918, 17919, 18440, 18442, 18498)
j. NAAQS for S02, N02, ozone, and PM (17821, 17918, 17919, 18440, 19506)

k. Area source Boiler MACT (18024)

Multiple commenters cite previous compliance timeline extensions that were granted:

a.	Marine Tank Vessels - 1 year (18023, 16469, 17254, 17368, 17403, 17623, 17681, 17696, 17734,
17758, 17775, 17837, 17840, 17857, 17902, 17931, 18033)

b.	Pulp and Paper Production - 8 years (17623, 17774)

c.	MON (17623, 17774)

d.	NESHAP for Secondary Lead Smelting - 1 year (17716, 17731)

Multiple commenters (8443, 17402, 17627, 17767, 17821, 17868, 18021, 18037, 18502) ask that the
EPA consider physical space limitations. According to the commenters, without sufficient space to
install control devices, units may have to be retired.

Commenter 18575 discusses its diverse generation portfolio and says that this usually mitigates price
fluctuations related to the cost of generation of any single resource. However, the commenter says that

307


-------
this diversity now guarantees that it will be affected by several of the new and pending EPA rules all in
the same timeframe, which will strain their ability to afford and meet compliance timelines. The
commenter gives the following examples:

1.	EGU MACT: As proposed, the commenter's coal-fired generation will be covered by the proposed

EGU MACT;

2.	RICE Rule: commenter's contracted generation from gas-fired, reciprocating internal combustion

units are covered under the EPA's recent RICE Rule;

3.	CSAPR: Commenter's Whelan Energy Center unit is covered by the CSAPR (formerly known as the

"Clean Air Transport Rule");

4.	CCR Rule: Commenter's coal-fired resources face compliance requirements related to the disposal of

coal combustion residuals from coal-fired power plants to be finalized by the EPA in 2012;

5.	GHG Rule: Commenter's facilities face restrictions under the upcoming NSPS for GHG emissions

from new and existing EGUs that are scheduled to be proposed in September of 2011 and finalized
by May 2012;

6.	316(b): On April 20, 2011, the EPA proposed its section 316(b) rule under the CWA that will require

changes in cooling water intake structures used to cool coal, gas and nuclear steam-electric
generating plants, including the Cooper Nuclear Station which forms a portion of the commenter's
generation portfolio.

7.	Regional Haze Rule: Commenter's Laramie River Station facility, located in Wyoming, faces

additional regulatory costs since the state's SIP is still under review and could face new, potentially
very expensive retrofit requirements to be completed by 2013, according to the EPA's Regional
Haze timeline.

Commenter 17911 asks that the EPA consider the unintended consequences of recommending
technologies that make CCR more difficult to recycle. The commenter suggests a 2-year moratorium on
implementation of the proposed rule until some of the interrelated rules are more fully defined.

Response to Comment 40: In this regulation the EPA provided the maximum 3-year compliance time
authorized under the statute. See section 112(i)(3)(A). Furthermore, the EPA's actions in other CAA
section 112 rulemaking actions authorizing longer compliance periods are no longer relevant. Since
those rules were issued, the D.C. Circuit Court has determined that the EPA does not have authority to
provide a compliance period in excess of 3 years. See NRDC v. EPA, 489 F.3d 1364, 1373-74 (D.C. Cir.
2007) (rejecting a 1-year extension for all sources in the category because of changes to reporting
requirements issued after the final rule setting forth the emission standards were initially promulgated
too short). However as discussed elsewhere in this document and much more fully in the preamble, the
permitting authorities do have authority to grant a 1-year extension under a range of circumstances.
Beyond that the CAA provides mechanisms for sources to come into compliance while maintaining
electric reliability.

The following is a response to the various reasons given in comments as to why the proposed
compliance time frame is too short. For a fuller discussion of these issues please see the Technical
Support Document entitled, "An Assessment of the Feasibility of Retrofits for the Toxics Rule" in the
docket.

Claims ofInfeasibility for 2015-16 Compliance

The EPA's authority for setting the compliance time frames is set out in the CAA. In developing this
proposed rule, the EPA has performed specific analysis to assess the feasibility (e.g., ability of

308


-------
companies to install the required controls within the compliance time-frame) and potential impact of the
proposed rule on reliability. For that analysis entitled "An Assessment of the Feasibility of Retrofits for
the Toxics Rule" dated March 9, 2011, the EPA has projected the quantity of each APC technology that
may need to be newly retrofitted and in service by the compliance date(s). The EPA used its IPM model
to analyze which APC technologies would likely be used, and in what quantities, to achieve compliance
with the proposed Toxics Rule.

The EPA's assessment shows that a reasonable, moderately paced effort of the power sector and
supporting industry, including some early starts, would result in many of the needed retrofits being
installed by January 2015 with some needing up to an additional year. In order for all retrofits to be
completed by January 2015, most projects would have to start early and the sector would have to engage
in a more aggressive deployment program. In the event that individual projects cannot be completed by
the January 2015 statutory deadline for compliance, the CAA offers affected sources the opportunity to
apply for a 1-year extension.

Claims That More Time is Needed for Small Entities To Comply

As stated above, the EPA's authority to provide more than three years to comply with the standards is
constrained by CAA section 112(i)(3)(A) and the D.C. Circuit Court interpretation of that provision. See
NRDC v. EPA, 489 F.3d 1364, 1373-74 (D.C. Cir. 2007) (rejecting a 1-year extension for all sources in
the category after the agency promulgated changes to reporting requirements issued after the final rule
setting forth the emission standards). The compliance provisions of the statute do not provide an
exception for small entities.

Inadequate Labor Pool, Low Skill Level & Insufficient Equipment Suppliers

With current unemployment rates, sufficient quantities of engineers and skilled craft exist for
implementation of this rule. Likewise, for the extreme case of local labor shortages (which is not
anticipated), this challenge can be overcome by instituting a workforce development action plan during
project execution. This sector's equipment suppliers and manufacturers are underutilized and have been
since 2010.

Site Congestion Can Lengthen Retrofit Timins and lead to retirement

One commenter suggested that the facilities that were easy to retrofit, did retrofit for compliance with
the acid rain program and CAIR. So what is left to retrofit under this program, is more difficult and will
take longer than retrofits in the past. Several commenters said that plants may retire because space
constraints would prohibit retrofitting.

Available space is a problem at many remaining facilities. Space constraints are a challenge that must be
addressed early in the design stage of a compliance strategy. There are a number of ways to economize
the available space but ultimately each plant is different and the solutions will be different. Many of the
controls that the EPA expects plants to use to comply with MATS, especially DSI and ACI, work well at
a space constrained facility. In addition, the EPA expects that in many cases it will be possible and
economic to combine emissions from several units into a larger control device. In such combined multi-
unit cases the installation time should be only slightly greater than for a single unit, and still feasible for
compliance by 2015-2016. In any event, a multi-unit retrofit on one site has significant execution cost
and schedule advantages not realized at multiple single unit stations through aggregating resources to
create economies of scale. These include one-time mobilization, extended equipment rental, dedicated

309


-------
staging area, efficient skilled craft utilization, and reduced administrative outlays. Furthermore, units can
be "tied-in" sequentially, avoiding a complete station shutdown during installation.

Successful examples include Dickerson Station's three 190 MW units feed a single scrubber which
discharges into a single flue stack. Chalk Point station's two units share a single common wet FGD.
FirstEnergy's Sammis station's wet scrubber project combined emissions from seven units into three
absorbers. AEP's Clifty Creek and Kyger Creek stations will employ similar design concepts for their
wet FGDs. And at WE Energies' Presque Isle facility several units are tied into one fabric filter.

Finally the rule allows facility averaging for existing EGUs in the same subcategory so that in many
cases it may be possible to retrofit only some of the units and achieve the standards.

Time frame for Compliance Is Too Short to Construct and Permit an FGD Landfill

The compliance deadline allows sufficient time for completing landfills for FGD solids disposal. For
example, DP&L will construct a landfill within 18 months to accept wastes generated from Stuart and
Killen stations scrubbers. The EPA notes, however, that retrofitting units do not necessarily need to
complete landfill construction ahead of commencing operation of the retrofit to achieve cost-effective
emission reductions under the Transport Rule programs. Such a source may either utilize a completed
portion of the newly permitted landfill under construction, transfer waste off-site to a permitted landfill
within the owner's fleet, or contract waste removal (and disposal) services. For example, Dallman
station subcontracts coal ash disposal at a local abandoned mine. The EPA uses a disposal cost
assumption of $30-$50 per ton for wet FGD, dry FGD, and DSI controls, which the EPA developed in
consultation with an experienced power sector engineering firm.

Short Time Frame Will Cause Electricity Rates to Rise

The EPA recognizes that this rule will cause electricity prices to rise. The EPA projects that the increase
in retail electricity prices that will result from this regulation range from 2 to 3 cents per kWh in 2015
and will decrease in the ensuing years. On average, this is a 2.9 percent increase and is well below
electricity prices seen historically and as recently as four or 5 years ago. The average increase over the
base case declines over time.

Multiple Rulemakings Necessitate a Lonser Compliance Time

A number of commenters said that the unusual number of regulations that the EPA is promulgating for
the electric power sector in approximately the same time frame compounds the problems caused by the
MATS compliance time. The EPA understands that there are a number of regulations that will set in
place standards that have to be met by this industry. The Cross-State Air Pollution Rule was
promulgated last summer and the Cooling Water Intake Rule will be promulgated next year. A
regulation setting standards for handling coal combustion waste has been under development for the past
few years. The confluence of these regulations allows the power industry to plan for compliance with
information about the full suite of requirements that they will face. It reduces uncertainty and provides
an opportunity for the power sector to develop integrated strategies for meeting EPA regulations
allowing for a cost effective approach on the part of the companies that takes account of the multiple
requirements. Many of these strategies will take advantage of the collateral effect of pollution control
technologies. For example, actions taken to reduce emissions under the Cross-State Rule will help
facilities achieve the acid gas and in many cases mercury standards in this rule.

310


-------
Smaller Plants Will Not be Able to Compete with Larger Plants for Controls

Some commenters said that smaller plants would have a harder time getting controls on plants within the
compliance time frame because they would not be able to compete with larger plants for equipment,
labor, and engineering and therefore they need a longer compliance time frame. Small plants are not
necessarily at a disadvantage. The EPA notes that smaller plants can often control very cost effectively
either because they simply need less equipment and labor to retrofit and because they can often tie more
than one small or midsize unit into one control device. Shared APC systems will allow the overall effort
to be more manageable than otherwise, and should require relatively fewer supply chain resources.

Smaller Companies Will Not be Able to Compete with Larger Companies for Controls

Several commenters said that small companies need more time to comply with the regulation because
they would not be able to compete with larger companies in the market for labor, equipment and
engineering services to comply with this regulation. This comment presumes that there is a shortage of
equipment, labor and materials to apply to compliance with this regulation. As stated elsewhere we are
in an economy that is characterized by high unemployment and chronic excess capacity. While this
regulation will modestly spur demand it cannot reasonably be expected stimulate enough demand to
cause shortages such that firms will have difficulty obtaining the services they need to comply.

Comment 41: Multiple commenters offer suggestions on methods for allowing more time for
compliance:

a.	Authority under section 112(n)(l)(A): (17403, 17799).

b.	State authority under section 112(i)(3): (18023, 9738, 16469, 17265, 17297, 17402, 17403, 17623,
17638, 17648, 17654, 17681, 17689, 17696, 17705, 17714, 17716, 17722, 17724, 17752, 17756, 17758,
17765, 17775, 17790, 17798, 17799, 17800, 17805, 17807, 17808, 17810, 17817, 17820, 17837, 17841,
17857, 17868, 17870, 17876, 17877, 17886, 17887, 18034, 18038, 18502, 18575)

c.	Presidential authority under section 112(i)(4): (18023, 16469, 16705, 16849, 17265, 17400, 17637,
17655, 17656, 17681, 17689, 17703, 17705, 17714, 17722, 17724 (5-year exemption), 17730, 17756,
17758, 17774, 17775, 17799, 17805 (5-year exemption), 17807, 17817, 17820, 17821, 17868, 17870,
17876 (5-year exemption), 17877, 17886, 17931, 18027, 18031, 18033, 18034, 18038, 18428, 18477,
18500, 18502, 18575)

d.	Categorical extension for publicly-owned or governmental facilities according to EO 13132, 13563,
and UMRA of 1995: (17868)

e.	State-designed programs under the delegation provisions of section 112: (17719, 17873)

f.	Delay Consent Decree: (17654, 17876, 17930)

g.	Through Administrative Orders of Consent (AOCs): (17808, 17868, 17870)

h.	Through Consent Decrees: (17648, 17808, 17870, 18448)

i.	Temporary waiver mechanisms: (17055)

311


-------
j. Adoption of MACT compliance schedules through minor permit modifications of a source's Title V
federal operating permits: (17868, 18422)

k. Compliance extensions for units that reduce early or install specified control equipment: (17265,
17638, 17681, 17807)

1. CAA section 112(i)(6): (17821; although the commenter argues that it offers no meaningful relief to
most sources)

m. Provide a future effective date for the rule. This approach would allow promulgation by the date
mandated by the consent decree, and would assist states and utilities by relieving the requirements of
case-by-case MACT determinations that must be made until the MACT standard is promulgated:

(18442)

Commenters 17648 and 18502 ask that the EPA allow use of consent agreements. Commenter 17648
states that as a matter of law and long-standing administrative practice, then, the requirements of the
Toxics Rule will apply without abatement to facilities subject to a consent arrangement, however, as a
matter of policy, the EPA may wish to accommodate certain consent arrangements that pre-date
publication of the proposed Toxics Rule in case-specific circumstances. Commenter 17648 explains that
most existing consent arrangements are directed to controls on criteria pollutants which will ordinarily
be insufficient to control HAP in a manner consistent with the rule. Commenter 17648 states that any
accommodation would need to provide for the implementation of HAP controls "as soon as practicable"
given existing commitments under the consent arrangement. According to the commenters, for example,
a consent arrangement that provides for installation during 2015 of a FGD system that would adequately
control acid gas HAP might be accommodated provided controls for Hg and non-Hg metal HAP were
installed prior to the compliance deadline.

Commenter 17648 suggests two options for accommodating consent arrangements:

1.	First, the EPA could authorize state permitting agencies to provide facilities subject to a consent
arrangement with the same 1-year extension from the applicable statutory deadline "for the installation
of controls" under section 112(i)(3)(B) available to other sources, assuming those facilities intend to
install controls before the end of 2015. According to the commenter, the EPA could exercise its
discretion as to whether to require facilities subject to a consent arrangement to comply with interim
operating conditions.

2.	The second option available to the EPA is to enter into a "wrap-around" consent order or consent
decree that would incorporate additional requirements necessary to comply with the Toxics Rule beyond
those required in the existing consent arrangement. The commenter states that this task must be
approached on a case-by-case basis, with the judicious use of the enforcement discretion by the EPA and
state permitting agencies and that existing consent arrangements are unlikely to provide for the
installation of emission controls sufficient to comply with the Toxics Rule. The commenter asserts that
EGU operators who are parties to such arrangements will bear the burden of deciding whether to seek
additional relief, or to comply with the rule on time. The commenter states that some consent
arrangements will be inadequate in scope or alacrity, or both, and will need to be supplemented either by
a "wrap-around" consent order or decree, or by an amendment to the existing arrangement. According to
the commenter, ultimately the same enforcement discretion that formed the basis of the existing consent
arrangements will be applied to determine if, and how, they must be modified, and the operating
conditions that should be applied during the period of extension. The commenter states that only in this

312


-------
way can the EPA and state permitting agencies conserve the benefits of these consent arrangements
without sacrificing the overwhelming health and economic benefits that the Toxics Rule will provide.

Response to Comment 41: The agency has provided the maximum time authorized under CAA section
112(i)(3)(A), and the provisions cited by commenters do not alter our authority concerning the initial
compliance time that may be provided in CAA section 112 standards. Furthermore, as the EPA stated in
the preamble to the final rule, our analysis shows that most plants can meet the standards within the 3-
year timeframe. The EPA believes that although most units will be able to fully comply within 3 years,
the fourth year that permitting authorities are allowed to grant for installation of controls is an important
flexibility that will address situations where an extra year is necessary. That fourth year should be
broadly available.. Furthermore, in the event that an isolated localized reliability concern was to emerge
that could not be addressed solely though the 1-year extension under CAA section 112(i)(3), the CAA
from provides some flexibility to assure reliability is maintained while facilities come into compliance.

Comment 42: Multiple commenters (18023, 16469, 17254, 17297, 17383, 17403, 17623, 17638, 17654,
17681, 17696, 17705, 17716, 17718, 17720, 17722, 17724, 17731, 17734, 17752, 17765, 17774, 17775,
17790, 17798, 17799, 17800, 17807, 17816, 17820, 17840, 17842, 17856, 17857, 17868, 17876, 17881,
17886, 17902, 17931, 18016, 18021, 18031, 18033, 18034, 18424, 18428, 18500) request a "blanket 1-
year extension" of the compliance deadline.

On the other hand, multiple commenters (9738, 17265, 17402, 17648, 17701, 17758, 17808, 17810,
17852, 17887, 17973, 18025, 18027, 18438) ask that requests be granted only on a case-by-case basis.

Response to Comment 42: CAA section 112(i)(3)(B) provides that "[t]he Administrator (or a State
with a program approved under subchapter V of this chapter) may issue a permit that grants an extension
permitting an existing source up to 1 additional year to comply with standards under subsection (d) of
this section if such additional period is necessary for the installation of controls." This provision on its
face applies to individual sources and, furthermore, the D.C. Circuit Court has determined that EPA
does not have authority to provide a compliance period in excess of three. See NRDC v. EPA, 489 F.3d
1364, 1373-74 (D.C. Cir. 2007) (rejecting a one year extension for all sources in the category after the
Agency promulgated changes to reporting requirements issued after the final rule setting forth the
emission standards). Some industry commenters have specifically stated that they will be able to comply
with the rule in the 3 year period and we believe that there are approximately 69 EGUs that appear to be
currently complying with all of the existing source standards. We do not think it would be reasonable or
consistent with the statute to provide a longer compliance period for sources currently complying and
sources that can in fact comply within 3 years. For sources that cannot comply in that time, the 1 year
compliance extension is available and EPA has committed to working with sources to ensure that
compliance with the final rule will not affect electric reliability.

Comment 43: Multiple commenters (16824, 17003, 17137, 17730, 18441) ask that compliance be
delayed until additional studies or analyses are conducted.

Commenter 16824 asks that the EPA complete a cost-benefit analysis (with further peer review and
additional opportunity for public comment) before implementing this rule.

Commenters 17137 and 17821 endorse an indefinite delay until further study can be undertaken on the
costs and impacts to industry, jobs, and consumers along with additional testing and evaluation.
According to commenter 17137, the current deadline meets neither "the test of reasonability nor
realism."

313


-------
Commenters 17003 and 17730 ask that the EPA undertake a formal assessment of the feasibility for
regulated sources to contract for equipment and manpower needed to meet compliance deadlines for the
Utility MACT and other pending regulations affecting coal-fired power generation.

Commenter 17003 asks that the EPA allow that a trial be undertaken to prove EPA's assumption that
acid gas can be removed at low cost.

Commenter 17821 asserts that non-Hg metallic HAP removal technologies need further study in the
same way that the DOE studied Hg.

Commenter 18441 states that full impact of the rule and the resulting generator decisions on whether to
comply or retire have not been made. According to the commenter, it is simply premature to reach a
definitive conclusion that the rule can be met without adversely impacting electric reliability. The
commenter states that although the EPA's analysis addresses overall system adequacy, the EPA has not
analyzed system security under the rule.

Response to Comment 43: The MATS was developed by the EPA after years of studies and data
analysis that examined the nature and quantity of HAP emissions from power plants, the health and
environmental effects of the pollution, the availability of pollution controls and other measures to reduce
emissions of these pollutants, the costs and benefits of reducing HAP emissions from EGUs, and the
effect of the rule on consumers and on jobs. What the EPA learned is that coal-fired and oil-fired power
plants are very large emitters of these pollutants, that cost effective strategies to reduce these emissions
are readily available, and that doing so, while expensive would provide public health benefits valued at
many times the cost, including avoiding premature deaths, more aggravated asthma and other respiratory
problems, non-fatal heart attacks, missed work and school days In the process the rule has little impact
on consumer prices and increases jobs moderately.

Although one can always argue for more studies, delaying this rule now for the purpose of more studies
would delay significant health benefits to hundreds of thousands of Americans.

Comment 44: Commenter 17682 worries that the rule as proposed will severely harm the ability of the
United States to produce reasonably priced power, diminish its international competitiveness, and result
in minimal environmental improvements, and that it could even result in increased environmental risks
from alternative energy sources, This commenter requested that the EPA withdraw the proposed rule.
Commenter further asks that the EPA reissue a new rule only if it reflects the results of a credible cost-
benefit analysis and a full assessment of the impacts of using potentially conflicting and relatively
untested MACT technologies to achieve compliance with the range of pollutant standards

Commenters 17003 and 17297 quote the EPA compliance cost estimates of a $3-4 increase in consumer
electricity costs and suggest that a longer compliance timeline to develop and implement the least cost
compliance strategy to ensure a reliable electric supply and minimal rate impacts.

Response to Comment 44: The impact of this rule on electricity and natural gas prices are within the
range of normal variability and well below levels seen only 2 or 3 years ago. It is not reasonable to take
as a "given" that this rule will diminish international competitiveness. In fact the annual cost of the rule
is less than 0.001 percent of GDP. It is unlikely to have much impact on the competitiveness of the U.S.
economy.

314


-------
The benefits of the rule on the other hand, according to the EPA's cost benefit study which is based on
peer reviewed scientific literature and methodologies are far greater than the costs, providing significant
public health improvements to Americans. Furthermore this regulation can be complied with using
tested control technologies that are in use on coal-fired plants today.

Comment 45: Multiple commenters (18023, 16850, 17402, 17403, 17623, 17648, 17655, 17686, 17705,
17736, 17757, 17758, 17800, 17805, 17840, 17873, 19114) offer opinions on the timelines for control
equipment installation. Commenter 19114 provides a detailed discussion of time frames for planning,
permitting and construction of controls in their comments.

a.	DSI:

(1)	9-18 months on average but up to 5 years recently (17758)

(2)	Two years (17402)

(3)	<12 months (17648)

b.	ACI: Up to 2 years for optimization after installation (17402)

c.	FGD:

(1)	Up to 60 months (17758)

(2)	40-69 months (18023)

(3)	36-42 months (17402)

(4)	40-60 months (17705)

(5)	40-65 months (17403)

(6)	52 months (17736, 19114)

(7)	44-64 months (17800)

(8)	66-72 months (17873)

(9)	2-4 years (16850)

(10)	40-65 months (17799)

(11)52	months (17821)

(12)	50-63 months (17886)

d.	FGD-associated landfill:

(1)	54 months on average (17736, 18428, 19114)

(2)	> 10 months (19114)

(3)	3-5 years for permitting (17800)

e.	Baghouse:

(1)	12-24 months (18421)

(2)	>36 months (18023, 19114)

(3)	>4 years for retrofit (17805)

f.	SCR:

(1)	36 months (1837)

(2)3	y2 years (17623, 18428)

315


-------
(3)	43 months (17655)

(4)	42 months (17736)

g.	Scrubber:

(1)	> 36 months (19114)

(2)	40-60 months (17623)

(3)	40-69 months, average of 50 months (18023)

(4)	4-5 year time frame (17757)

(5)	4-5 years (17736)

(6)	48-54 months (17840)

(7)	2-3 years (16850)

(8)	52-58 months (17627, 18037)

(9)3-5	years (17817)

(10)	45-58 months (17820)

h.	New generation: 6 years (18023)

i.	Changes in fuel supply to natural gas: 4 V2 years (18023)
j. Changes to transmission grid:

(1)	>3 years (18023)

(2)	up to 7 years (17886)

k. Fabric filter:

(1)	42 months (17736, 17821)

(2)	5.5 years (17840)

(3)	>=36 months (17868)

1. DSI with baghouse: 50+ months (17886)

Commenter 17868 notes that the EPA's assumption of faster retrofits is probably incorrect.

Response to Comment 45: Numerous commenters submitted their own evaluation of the length of time
required to install controls, switch fuels, and upgrade the grid, some of it based on their own experience
from the past. Numerous commenters claimed that actual project execution timeframes exceeded the
time allotted by the proposed rule. To illustrate the point, some commenters referenced specific retrofit
project elements with asserted time requirements for their completion as part of the retrofitting process.

The EPA does not agree with commenters that lengthy retrofit schedules from various individual prior
projects are dispositive of the power sector's ability to install cost-effective retrofits under the MATS
schedule. Project schedule length is heavily influenced by resource dedication and execution method.
While any project can be executed at a slow pace, the EGU pollution controls industry developed into a
mature industry in response to the Acid Rain Program, the NOx SIP Call, and CAIR with the ability to
perform accelerated project execution using a faster and more efficient Design-Build process. The power
sector has realized considerable efficiency gains through integrating standardized equipment designs,

316


-------
systems approach, and modular construction techniques as well as the formation of business alliances 1
to reduce frictional time lags.

A typical control retrofit project consists of the following elements, several of which may occur
simultaneously: site studies, conceptual engineering, equipment sizing, and cost estimating, planning,
detailed design, procurement, construction, commissioning/testing, and permit application. For design-
build methodology, the project is divided into two major phases: pre-award work requiring minor
expenditures (site studies, conceptual engineering, equipment sizing, cost estimates, schedule planning)
and award work requiring significant capital commitment (detailed design, procurement, construction,
commissioning/testing).

Pre-award work elements are typically executed sequentially since each preceding stage's results inform
the following stage; however, award work elements can be executed with "Lean Construction"
techniques to shorten time frames. Since a typical emission control device is a combination of, rail car
unloading, waste water treatment, and dewatering facility occupy different plant site locations; thereby,
allowing simultaneous design, procurement, construction, and testing activities. To illustrate the point,
Asheville Power station FGD retrofit was completed on a 26 month schedule. Constellation's FGD,
fabric filter, and activated carbon retrofit was completed in 29 months from notice to proceed. Presque
Isle's 3-unit fabric retrofit was completed in approximately 2 years.

The examples cited by commenters fail to account for the adoption of proven faster execution methods
evidenced by numerous units that have demonstrated FGD retrofit project completion in less than 30
months. In particular, commenters who cite examples of lengthy or delayed retrofit schedules from
projects conducted during the highly uncertain period of the CAIR remand (when it was prudent to
proceed cautiously) cannot reasonably expect such experiences to apply to retrofit project execution
with the benefit of renewed regulatory certainty gained by promulgation of the final MATS rule (when it
is prudent to proceed expeditiously and with confidence).

Evidence that almost all future APC retrofits can be completed far more quickly than were historical
APC projects derives in part from a comparison of past APC schedules to the project schedule for an
entire new coal-fired unit, including its APC systems. Springerville Unit 3, for example, is a 400 MW
coal-fired unit that became operational in July 2006, some 33 months after the turnkey engineering-
construction contractor was given a notice to proceed with engineering. 5 Springerville was clearly on an
accelerated schedule, as its original planned schedule was about 38 months. The main point here is that
typical schedules for large complex power projects can be significantly accelerated. Because the scope
of the work involved for an entire new coal unit is at least five times that of a retrofit wet FGD system,
EPA believes that even the most complex retrofit APC project can be significantly accelerated as well.

The recently surveyed wet FGD project schedules are not all representative of the shorter project
schedules that EPA expects to be prevalent under the MATS Rule. Some of these projects were
conducted in a period of regulatory uncertainty without a strong driver for accelerated retrofit
completion, tie-in, and subsequent operation - particularly where initiating such operation increases
marginal operating costs without a certain regulatory benefit. Factors that will likely accelerate project
schedules under the Toxics Rule include the use of overtime and/or two-shift work schedules during
construction, and 5- or 6-day work weeks, instead of the 4-day xlO-hr schedules often used to minimize
cost when time is not of the essence. Increased use of offsite modularization and pre-fabrication of APC
components can also shorten schedules and reduce job hours. Also, many of the wet FGD projects
performed in response to CAIR or to other legal actions in the same time frame took longer to perform
than under normal market conditions due to the initial high demand for a large number of complex wet

317


-------
FGD systems in a short period of time. Extended lead times in the 2007/2008 time period, as high as 18
months for key wet FGD engineered equipment (such as large recycle pumps, large motors, and
chimneys) contributed to extended wet FGD project durations. Increased lead times quickly subsided as
the supply chain processed the initial influx of orders for this equipment. Neither the proposed Cross
State Rule nor the MATS Rule, however, is projected to require a significant number of large, complex
wet FGD systems. The relatively much simpler dry FGD, fabric filter, and other even simpler DSI and
ACI systems that may be required under the Mercury and Air Toxics rule will take significantly less
time to plan, design, install, and commission than wet FGDs.

5. One-year extension.

Comment 46: The EPA requested comment on a 1-year extension under section 112(i)(3) for
"installation of controls." Multiple commenters (18023, 9738, 17297, 17638, 17648, 17696, 17758,
17775, 17810, 17818, 17841, 17843, 17870, 17886, 18025, 18037, 18424, 18426, 18428, 18440, 19114)
agree with the extension.

Commenter 18025 states that in the limited cases of extensions beyond 3 years, it will be important for
the EPA to ensure that a company uses the additional time to install controls or test the installation of
controls and to ensure a unit is only dispatched for reliability purposes so that it does not receive any
undue economic gain as a result of an extension.

Multiple commenters (18023, 17297, 17385, 17638, 17696, 17701, 17758, 17775, 17820, 18426, 18434,
18439) ask that the 1-year extension apply in other cases as well. Multiple commenters (18023, 17297,
17758, 17775, 17820, 17886, 19114) also support applying the extension to transmission upgrades.
Commenter 19114 asks that the extension should apply if additional gas supply lines must be
constructed or replaced, or if required state and federal regulatory approvals to retire the capacity cannot
be obtained.

Commenter 17385 asks for clarification of whether energy efficiency and fuel switching measures can
count as "controls."

Commenter 18434 stated that this extension should also apply to on-site non-conventional replacement
generation through combined heat and power and waste heat recovery. According to the commenter,
restricting replacement power to on-site equipment significantly reduces opportunities for facilities to
invest in clean replacement power and consider retirement as a compliance strategy. The commenter
states that this approach has multiple advantages.

Several commenters (18434, 18439, 19114) ask the EPA to clarify that retirement and any clean
replacement power that complies with the NESHAP rule, including off-site combined heat and power
and waste heat recovery, can be deemed "controls" under the CAA, thereby allowing the same 1-year
extension to apply. Commenter 18439 notes that the EPA should clarify that energy efficiency and fuel
switching measures can count as controls for purposes of eligibility for a 1-year extension for
compliance if additional time is needed for installation. Commenter 19114 notes that the timeline for
constructing a new combined cycle unit is similar to that for retrofitting an FGD system on an existing
unit, and could not be completed within a 3-year window.

Several commenters (19536, 19537, 19538) believe that: Shut-down of an existing unit is within the
definition of a pollution "control" under section 112, as well as under the CAA generally. The
commenters state that section 112 uses "emission control" broadly to refer to pollution reductions of any

318


-------
sort(see, e.g., 42 U.S.C. §7412(d)(3), (d)(5), (d)(6), & h(l) (all using "control" to refer to pollution-
reduction and referring to "emission control" achieved by "best controlled similar source")), that in
keeping with that general synonymy, section 112 defines "maximum achievable control technology"
limit as a limit reflecting the "maximum degree of reduction" achievable(42 U.S.C. §7412(d)(2) &
(g)(2)), and the statute confirms that any "measure," "method" or "technique" that reduces hazardous air
pollution may be prescribed to accomplish the necessary limitation(42 U.S.C. §7412(d)(2)). The
commenters state that elsewhere in the statute, as well, the term "control" is defined broadly enough to
include the cessation of polluting operations. See, e.g., 42 U.S.C. §7479 (defining "best achievable
control technology"). According to the commenters, closure of a high-polluting unit is a measure that
reduces pollution, and is therefore a "control" under the CAA. The commenters state that the EPA has,
accordingly, recognized in its consent decrees that shut-down is under some circumstances a method of
pollution-reduction that is a "control technology" within the meaning of the CAA. See, e.g., Consent
Decree, United States v. Tampa Electric Co., Civ. No. 99-2524 (M.D. Fla. 204) at 7-8 (prescribing
permanent shut-down amongst "emissions reductions and controls" required to comply with CAA).
According to the commenter, consequently, the word "control" in section 112 encompasses the shut-
down of a polluting unit, and "installation of controls" should be understood to include the on-site
physical operations required to accomplish permanent shut-down. Also according to the commenter, the
accompanying term "practicable," in section 112(i)(3)(A), allows the EPA to consider the need to
provide replacement power necessary to permit such a permanent shut-down. The commenter states that
section 112(i)(3) allows the EPA (or state agencies) to provide up to 1 additional year to an existing
source where "necessary for the installation of controls," 42 U.S.C. §7412(i)(3)(B), while also
establishing that controls are to be installed "as expeditiously as practicable," 42 U.S.C. §7412(i)(3)(A).
The commenter states that whether an extension is "necessary" for the installation of controls must be
informed by whether those controls can "practicabl[y]" be put in place at an earlier date. According to
the commenter, read together, sections 112(i)(3)(A) & (B) allow an extension of up to 1 year to be
granted on a case-by-case basis for facilities at which controls cannot practicably be installed within 3
years. The commenter states that the EPA has, elsewhere in its proposed rulemaking, considered
reliability to determine the pace at which controls can practicably be installed (see 76 FR 25,054, 25,056
& nn. 177-178 (describing EPA's efforts and intention to work with FERC, NERC, the Department of
Energy, and regional transmission organizations on issues related to compliance and reliability,
particularly in the event unit shutdowns occur in load-constrained areas)).

Commenter 18426 states that the extension, with the factors and conditions for qualifying and applying
for the extension, needs to be part of the rule. The commenter provided Michigan's conditions for that
state's Hg rules.

Commenter 18034 requests clarification, as the commenter is unaware of any precedent for such an
interpretation of the CAA. The commenter states that while the EPA's attempt at flexibility through this
interpretation is clear, the commenter is unclear as how other parts of the proposed NESHAP rule should
be interpreted and enforced given this new interpretation and poses the following questions: Would such
a reconstructed facility be held to the new or reconstructed EGU emission limits in Table 1 or the
existing EGU emission limits in Table 2? How does the EPA reconcile this interpretation with the
proposed requirement in section 63.9984(a) that a new or reconstructed EGU must comply by the date
of the final rule published in the Federal Register or upon restart of the EGU, whichever is later? Is this
interpretation limited to just EGUs or may states apply this same approach to existing sources subject to
other NESHAP rules, for example, a Portland cement kiln subject to the EPA's recently finalized
Portland cement NESHAP rule?

319


-------
Commenter 19122 states that the 1-year extension process seems to apply only to the installation of
control equipment and not for installation of systems such as CEMS and BLDS. The commenter
recommends that the EPA provide an extension process for procurement of emission monitoring/BLDS
as well as for installation of control equipment and streamline the extension process such that a source
can be granted an extension if good faith efforts have been made to meet compliance.

Commenter 17868 outlines the EPA prediction that the industry will have very little problem in meeting
the 3-year compliance schedule proposed in the regulation if the additional year of compliance time is
provided to "some" units. The commenter provides their key assumptions supporting this conclusion as:

1.	The use of low-cost, simple, DSI systems to control acid gases, instead of more complex FGD

systems;

2.	Faster retrofits than similar projects in the past;

3.	Compliance requirements of other regulations have no impact on HAP compliance;

4.	The small number of projected retirements, about 10 GW of coal capacity;

5.	Early planning action by regulated utilities; and

6.	Early planning action by RTOs.

Comment 47: Multiple commenters (16850, 17004, 17026, 17887, 18539) comment on retiring or
repowering units.

Commenters 17004 and 17026 request that the EPA allow power companies to operate their plants as
efficiently as possible, including allowing units that are already scheduled to shut down to operate on a
restricted basis without installing additional controls, as they upgrade their facilities and move toward
new generation.

Commenters 18434 and 18439 ask the EPA to clarify that retirement and any clean replacement power
that complies with the NESHAP rule, including off-site combined heat and power and waste heat
recovery, can be deemed "controls" under the CAA.

6. Extensions for retirement and replacement power.

Comment 48: Several commenters (18023, 17638, 17696, 17820, 17821) ask that the provision to allow
a 1-year extension apply to all retirements.

Multiple commenters (17841, 18426, 18434, 18441, 18442 18448) ask that a 1-year extension be
provided for possible unit retirements, retrofits, or repowering. Several commenters (18434, 18441,
19114) note that this extension should apply to off-site power generation in limited circumstances.
Commenters 18031 and 18442 ask that the maximum amount of time allowable be available for these
actions.

Commenter 17677 states that for units that elect to shutdown, the EPA should allow significant
automatic extensions upon notification of elected unit shutdown. According to the commenter, this will
allow the source sufficient time to permit and construct a replacement facility or contract additional
power that will most likely have to be constructed.

Commenter 19506 states that the EPA should consider allowing units that a company has scheduled to
be shut down to continue to operate beyond the compliance deadline until other units owned by the same
company have been fully retrofitted.

320


-------
Commenter 18450 opposes allowing a fourth year for compliance when building replacement power
unless the source can demonstrate an electric reliability issue.

Commenter 18039 objects to granting 1-year extensions for facilities that are building replacement
power. According to the commenter, the EPA should avoid allowing a facility in the process of building
replacement power, and that would otherwise shut down an existing high-emitting unit at the 3-year
compliance deadline, to operate such existing high-emitting unit for an additional year, specifically due
to the 1-year extension. The commenter states that in addition, if designing, permitting and constructing
replacement power continues beyond a 1-year extension, it should be stressed that the CAA does not
allow MACT compliance extension beyond 1-year, whether or not a replacement unit has come on-line.

Commenter 18441 notes that the 1-year extension request, if granted, may create incentives for
generation owners faced with compliance decisions to wait as long as possible to submit their
deactivation requests to their regional transmission organization in the hope they can get their units
extended beyond the January 1, 2015 compliance deadline if their units are deemed by the regional
transmission organization in its subsequent deactivation study to be Reliability Critical Units. According
to the commenter, in this case, generator owners can effectively attempt to extend the life of their units
for an additional year or more with no intention of installing retrofits by simply delaying their
deactivation request so they can effectively side-step compliance with the final rule through a potential
misuse of the extension process contemplated herein. The commenter requests the EPA provide
guidance in the final rule that such an extension for deactivating units only be granted if the unit owners
provide the regional transmission organization, with a copy to the EPA, with notice of deactivation by
the earlier of 12 months from the effective date of the final rule, or January 1, 2013, a full 2 years in
advance of the January 1, 2015 compliance deadline. The commenter notes that nothing in this proposal
should be read as limiting the ability of units which are retrofitting but cannot complete such work by
the compliance deadline from also being eligible for a compliance extension. The commenter states that
nothing in this proposal eliminates a generating owner from petitioning the Secretary of Energy to
excise its authority under section 202(c) of the Federal Power Act and section 301(b) of the Department
of Energy Organization Act to order the unit remain operational, and nor would this preclude a generator
from working with the EPA to establish a compliance schedule.

Response to Comments 46-48: The EPA believes that although most units will be able to fully comply
within 3 years, the fourth year that permitting authorities are allowed to grant for installation of controls
is an important flexibility that will address situations where an extra year is necessary. That fourth year
should be broadly available where it is necessary. Please refer to the preamble where there is a detailed
discussion of the fourth year. The EPA is making it clear that permitting authorities have the authority to
grant a 1-year compliance extension where appropriate.

The EPA continues to believe that most, if not all, units will be able to comply with the requirements of
this rule within 3 years. The EPA also believes that making it clear that permitting authorities have the
authority to grant a 1-year compliance extension where necessary, in range of situations described in the
preamble, addresses many of the other concerns that commenters have raised.

7. Issues and costs that need to be considered in determining compliance date.

Comment 49: Multiple commenters (16469, 16849, 17403, 17406, 17640, 17722, 17730, 17732, 17734,
17752, 17756, 17757, 17758, 17770, 17774, 17812, 17813, 17815, 17817, 17820, 17821, and 17868,
17876, 17881, 17912, 17925, 17931, 18033, 18037, 18422, 18424, 18428, 18440, 18442, 18447, 18498,

321


-------
18500, 19114, 19122, 19506) are concerned about the availability of qualified construction and technical
labor, as well as availability of equipment.

Multiple commenters (8443, 17383, 17608, 17697, 17722, 17767, 17812, 17868, 17911, 18038, 18419,
18498, 18575) are concerned about the competition between small utilities and larger utilities, for
equipment and labor.

Commenter 18433 states that it will be difficult for facilities in remote areas to get vendors and
contractors to respond to requests-for-proposals for a single opportunity to sell an ESP when large
utilities will also be seeking larger quantities of such equipment from the same vendors.

Commenters 19032 and 19653 believe that too many activities must be coordinated and completed to
comply with the proposed rule. The commenter states that these activities include emissions testing to
determine what type of capital equipment or upgrades will be required to facilitate compliance,
Designing/engineering, permitting, securing financing, construction, start-up and acceptance testing.

Comment 50: Multiple commenters (16849, 17403, 17731, 17752, 17757, 17774, 17775, 17821,
18428) are concerned about major tie-in outages, especially during low peak seasons.

Commenter 18477 does not have shoulder months like the contiguous U.S. Therefore, according to the
commenter, there are no specific time periods when outages can occur without impacting electric
reliability.

Response to Comments 49 - 50: In both the preamble to the rule and in greater detail in the TSD, the
EPA has assessed the feasibility of installing these controls within the compliance window and believes
that the controls can be reasonably installed within that time. Although the EPA assessed the ability to
install the controls in 3 years (and determined that the controls could be installed in that time-frame),
this would require the control technology industry to ramp up quickly. Therefore, the EPA also assessed
a time-frame that would allow some installations to take up to 4 years. This time-frame is consistent
with the CAA which allows permitting authorities the discretion to grant extensions to the compliance
time-line of up to 1 year. This time-frame also allows for staggered installation of controls at facilities
that need to install technologies on multiple units. Staggered installation allows companies to address
such issues as scheduling outages at different units so that reliable power can be provided during these
outage periods or particularly complex retrofits (e.g., when controls for one unit need to be located in an
open area needed to construct controls on another unit). In other words, the additional 1-year extension
would provide an additional two shoulder periods to schedule outages. It also provides additional
opportunity to spread complex outages over multiple outage periods. The EPA believes that while many
units will be able to fully comply within 3 years, the 4th year that permitting authorities are allowed to
grant for installation of controls is an important flexibility that will address situations where an extra
year is necessary. The EPA expects that state permitting authorities will make the fourth year available
where it is warranted. In addition where necessary to avoid a violation of applicable FERC-approved
electric reliability standards the EPA can use existing CAA authorities to allow additional time to come
into compliance.

Comment 51: Multiple commenters (8443, 17123, 17297, 17406, 17623, 17716, 17732, 17756, 17716,
17752, 17758, 17820, 17842, 17912, 18024, 18419, 18422, 18440, 18502, 19121) are concerned about
financing these projects and the likely cost increases for labor and equipment likely to occur over this
compliance period.

322


-------
Multiple commenters (17254, 17406, 17842, 18422, 18437, 18502, 18539, 18575, 19653) are concerned
that these increased costs could affect the affordability of electricity.

Response to Comment 51: The EPA has not observed financing obstacles for pollution control retrofits
under its previous programs. The EPA includes publicly-reviewed financial assumptions regarding
pollution control investments with its IPM modeling of the power sector. Furthermore, the financial
industry views utilities with large customer bases (e.g., AEP, Duke, Edison Intl., Southern Co., TVA) as
less risky to finance due to the consistent, ample revenue stream. To reduce financing risk, utilities have
the option to award "fixed price" contracts with penalties for exceeding price limits or LD's (liquidated
damages) for schedule and/or performance default. Considering the past successes of the pollution
control industry regarding retrofits, the EPA believes the financial markets will supply adequate capital
for units pursuing retrofit under the final MATS.

Although costs could increase during the compliance period, the EPA anticipates the first wave of
retrofit controls orders to be less costly than recent historical prices since suppliers shall compete for
work to utilize idle resources. For example, in June 2011 NIPSCO awarded B&W a contract worth $54
million for two wet scrubbers at R.M. Schahfer Generating Station with an operational date of autumn
2013 and 2015 for units #14 (465 MW) and #15 (515 MW), respectively. In another example, Colorado
Springs Utility plans to retrofit its 254 MW Martin Drake unit with a FGD for $113 million with
projected construction completed by 2014. The EPA expects therefore that the costs it has used in its
IPM modeling will be accurate over the life of the compliance period. Documentation for IPM can be
found in the docket for this rulemaking or at http://www.epa.gov/airmarkets/progsregs/epa-
ipm/index.html or at http://www.epa.gov/airmarkets/progsregs/epa-ipm/index.html.

Comment 52: Multiple commenters (18023, 17254, 17640, 17689, 17705, 17716, 17730, 17731,
17761, 17767, 17774, 17808, 17813, 17820, 17821, 17824, 17837, 17841, 17876, 17902, 17931, 18033,
18038, 18419, 18422, 18424, 18428, 18430, 18441, 18442, 18500, 18539, 18575, 19114, 19653) are
concerned about grid and electricity reliability.

Commenter 18441 states that the larger regional adequacy impacts can only be determined once the
impact of the final rule has been analyzed and units have made their individual retrofit vs. retirement
decisions. The commenter believes that the EPA understates the number and size of retirements.

Comment 53: Many commenters (16549, 17055, 17701, 17137, 17697, 17716, 17724, 17725, 17743,
17745, 17757, 17761, 17774, 17775, 17813, 17791, 18038, 18437, 18433, 17887, 17930, 18448, 18540,
19506, 19199) express concern that the EGU MACT will jeopardize the reliability of the U.S. electricity
supply by reducing generating capacity through early retirement of EGUs.

Numerous commenters (16549, 17055, 17701, 17137, 17697, 17716, 17724, 17725, 17743, 17745,
17757, 17761, 17774, 17775, 17813, 17791, 18038, 18437, 18433, 17887, 17930, 18448, 18540, 19506,
19199) express concern that the EGU MACT will jeopardize the reliability of the U.S. electricity supply
by reducing generating capacity through early retirement of EGUs. Some commenters (18034, 18538,
18907) believe that the EGU MACT may result in rolling blackouts that have economic impacts.
Commenter 18034 notes that without reliable, affordable electricity, sensitive populations, such as
elderly citizens, may be at risk during severe winter weather or hot summer temperatures.

Some commenters offer comments about processes based on early notification that might be set up to
assure that the compliance timeframe did not interfere with electricity reliability. Commentor 17648
suggests that the EPA be notified within 1 year of the effective date of this rule, of compliance plans

323


-------
including plans to retire units. Commenters 18441 and 18448 recommend that plants be required to
notify RTOs and ISOs of their plants to retire units so that the RTO/ISO can assess the impact on
reliability of the planned closure. In the event that a unit is deemed "reliability critical" the ISO/RTO
can plan transmission upgrades and other actions to avoid a loss of grid stability. These commenters
envision a "proforma consent decree" to provide additional time if needed.

Comment 54: Commenter 18023 believes the loss of generation capacity caused by early retirement of
EGUs would undermine the operational support that is critical to maintaining balance, resilience, and
contingency response capability on the bulk power network. The commenter believes the EPA has
overlooked the critical role generation capacity plays in providing grid stability.

Comment 55: Numerous commenters (16705, 17055, 17254, 17400, 17403, 17608, 17627, 17761,
17765, 17804, 17813, 17857, 17901, 17911, 17813, 17901, 17904, 17911, 17919, 17930, 18034, 18038,
18437, 18441, 18497, 18500, 18538, 18575, 18023) believe that the EPA has underestimated the
number of EGU retirements. Many commenters (16705, 17055, 17403, 17761, 17765, 17627, 17761,
17813, 17901, 17911, 17813, 17901, 17904, 17911, 17919, 17930, 18034, 18038, 18437, 18441, 18497,
18500, 18538, 18575, 18023) cite independent projections that estimate capacity retirements will be
much higher than the EPA's estimate. The independent projections cited by commenters include:

•	Potential Coal Plant Retirements Under Emerging Environmental Regulations, The Brattle
Group, December 8, 2010 (estimate 67 GW will be retired as a result of the EGU MACT);

•	Potential Impacts of Environmental Regulation on the U.S. Generation Fleet, Edison Electric
Institute, prepared by ICF International, January 2011 (estimate 50to 70 GW will be retired as a
result of the EGU MACT in conjunction with other new EPA regulations).

•	Review of the Potential Impacts of Proposed Environmental Regulations on the ERCOT System,
Electric Reliability Council of Texas, May 11, 2011 (predicts that by 2016, the base case
scenario will lead to 11 GW of retirements in the state of Texas to all forms of generating
capacity, leaving only a -2.3% reserve margin);

•	US Department of Energy (Deputy Assistant Secretary, James Wood) (suggested that the
approval of new rules for air pollution, water pollution and waste disposal could result in the
retirement of up to 70 GW of coal-fueled power generation nationwide. Woods highlighted that
these retirements will increase electric rates and lead to pronounced transmission grid reliability
issues ".. .both because of the shutdowns and because of the intermittency of renewables.").

•	Ira Shavel & Barclay Gibbs, Charles River Associates, "A Reliability Assessment of EPA's
Proposed Transport Rule and Forthcoming Utility MACT" (Dec. 16, 2010)(estimate 39 GW will
be lost through early retirement).

•	2010 Special Reliability Scenario Assessment: Resource Adequacy Impacts of Potential U.S.
Environmental Regulations, North American Electric Reliability Corporation, October 2010
(Estimate that 78 GW from coal, oil, and gas EGUs will be lost through early retirement over the
next 10 years).

•	U.S. Utilities: Coal-Fired Generation Is Squeezed in the Vice of EPA Regulation; Who Wins and
Who Loses?, Bernstein Research, October 2010. (estimate that close to 60 GW of coal fueled
capacity will find it "uneconomic" to install MACT and will shut down. Also predicts that
capacity margins would decrease by 7 to 15 % and reliability is forecasted to go down).

•	NERA Economic Consulting, May 2011 (estimates 48 GW of additional coal-fired generating
capacity will retire prematurely by 2016).

•	PIRA (states that over 160 GW of coal units do not currently have scrubbers installed. Of these,
about 55 GW have announced plans for scrubber retrofits, leaving a potentially large universe
(over 105 GW) of "vulnerable coal units").

324


-------
•	Credit Suisse, April 26, 2011 (predicts that at a 60 GW retirement capacity and suggests an
additional 24 GW would be needed to maintain reserve margins at 15 %).

Some utilities provide projections of the capacity they anticipate retiring as a result of this rule. These
include:

•	Commenter 17627 estimates that 5.4 GW of coal-based generation capacity will be lost as a
result of the EPA's regulations;

•	Commenter 17757 estimates that 5 coal-fired plants (6,000 MW) will be shut down as a result of
the EGU MACT.

•	Commenter 17821 plans to retire 6 units, or l,125MWs of coal fired capacity at the W.C.
Beckjord Station by January 1, 2015, principally due to the EGU MACT rule.

•	Commenter 17821 plans to retire the 163 MW Miami Fort Unit 6 on January 1, 2015.

•	Commenter 17821 estimates that approximately 1,574 MWs of additional coal-fired capacity is
at risk of shutdown due to new or pending EPA regulations, including the EGU MACT rule.

Comment 56: Commenters 17919 and 18033 refer to statements made by FERC that acknowledge
FERC's preliminary assessment on the impact of EPA rules on coal-fired generating capacity "showed
40 GW of coal-fired generating capacity 'likely' to retire, with another 41 GW 'very likely' to retire."
(see letter dated August 1, 2011 from the FERC Chairman John Wellinghoff). Commenter 17919 also
quotes from another letter from FERC Commissioner Marc Spitzer in which he argues that regulated
entities should not have to make such a "Hobson's" choice between EPA regulations on reliability
and entities' requirements to uphold FERC-approved reliability standards. Commenter 18033 claims that
the EPA has failed to document its discussions with FERC on the impacts of the EGU MACT on electric
system reliability. This commenter believes it is inappropriate for the EPA not to include a record of
those discussions in the rulemaking docket and that by not doing so the EPA has not adhered to the
statutory requirements of the CAA, which requires the EPA to provide the public with an opportunity to
review and comment on these documents.

Commenter 18033 states that the EPA also attempts to fall-back on early collaboration with key
stakeholders to prevent the potential for skyrocketing electricity prices and job losses. According to the
commenter, the agency states that, "[i]n addition, EPA itself has already begun reaching out to key
stakeholders including not only sources with direct compliance obligations, but also groups with
responsibility to assure an affordable and reliable supply of electricity including state Public Utility
Commissions (PUC), Regional Transmission Organizations (RTOs), the National Electric Reliability
Council (NERC), the Federal Energy Regulatory Commission (FERC), and DOE." The EPA further
states, "[i]t is EPA's understanding that FERC and DOE will work with entities to ensure an affordable,
reliable supply of electricity..." The commenter states that it can find no evidence of these consultations
in the rulemaking docket and that the public has no ability to discern whether EPA is presenting the
implications of this rule with its overly optimistic DSI assumption thereby coloring the perceptions of
the stakeholder. The commenter states that as of October 2010, NERC as one of the identified
stakeholders did not share the EPA's view of de minimus impacts to electric power generating sector.
According to the commenter, overlapping compliance schedules for the air and solid waste regulations,
along with the required compliance for rule 316(b) following shortly thereafter, may trigger a large
influx of environmental construction projects at the same time as new replacement generating capacity is
needed. The commenter states that such a large construction increase could cause potential bottlenecks
and delays in engineering, permitting and construction. The commenter asserts that based on this
assessment, either NERC has changed its position since this time to align with the EPA based on
information not included in the rulemaking docket, or the EPA is not being forthcoming about the reality

325


-------
of these "collaborations" to deal with this important issue. The commenter states that in any event, and
unsurprisingly, the foregoing demonstrates that FERC - responsible for delivering reliable electricity to
the country - is not as confident in the EPA's assessment of the situation as the EPA portrays it to be.

Following FERC's responses to Senator Murkowski, the commenter joins the Senator's extreme concern
with the impending situation, as described in her August 3 press release, "[hjaving received FERC's
responses this week, I must say that I am now less confident [after initially hearing the Chairman's plans
for an interagency task force] of that being the case." The commenter states that preliminary review of
FERC's responses completely validates her position.

The commenter states that in response to the EPA's exaggerated representations in the preamble,
Chairman Wellinghoff stated in his letter, ".. .this information assessment offered only a preliminary
look at how coal-fired generating units could be impacted by EPA rules, and is inadequate to use as a
basis for decision-making, given that it used information and assumptions that have changed" (emphasis
added). The commenter states that this sentiment is further confirmed in Commissioner Moeller's
response, "[ajccording to OER staff, EPA's reliability analysis has been limited," and that staff have,
"pointed out to EPA that a reliability analysis should explore transmission flows on the grid, reactive
power deficiencies related to closures, loss of frequency response, black start capability, local area
constraints, and transmission delivery" (emphasis added). According to the commenter, in sum, the
EPA's "trust us" mentality has far underestimated the complexity underlying the delivery of affordable
and reliable electricity.

The commenter states that this is further evidenced by the fact that neither FERC nor the EPA has
conducted a cumulative impacts analysis and that FERC's assessment that 81 GW of "likely or very
likely" retirements may result from the implementation of this suite of rules, further highlights the need -
- as expressed by the commenter - for a more transparent and open process to deal with these important
issues. The commenter states that recognizing the Chairman's reservations about the results of this
preliminary study, it nevertheless highlights the EPA's failure to disclose this critical study and any
other material that may exist regarding the EPA-FERC consultation process.

The commenter joins Commissioner Moeller's recommendations to have FERC: (1) use its expertise to
perform an analysis of the EPA's rules that could impact reliability of electricity - and disclose that
analysis for public comment - and then hold a technical conference for public input; and (2) have the
EPA extend the timing of these regulations as the agency's schedule "does not conform to the relevant
planning horizons in the electric sector of our economy, one of the most capital-intensive sectors of
industry."

The commenter states that understatement of potential coal-fired EGU retirements and electricity prices
will be especially acute if the EPA holds the line with its new source emissions limits. The commenter
states its belief that the new source emissions standards are based on the impermissible HAP-by-HAP
approach, which makes it difficult to foresee investment in new coal. According to the commenter,
Credit Suisse projects that at a 60 GW retirement figure, there would need to be an additional 24 GW
just to maintain reserve margins at 15% begging the important question of where will coal-dependent
regions of the county replace these important sources of energy. The commenter states that despite the
EPA's effort to "level the playing field," the agency has done an inadequate job of informing the public
as to the consequences of such a policy and that the public will only be able to confirm if the EPA
includes all of the relevant documents regarding this particular issue. The commenter asserts that the
public is entitled to an opportunity to inspect these documents and provide comment.

326


-------
The commenter states that the failure to provide evidence of the communication between FERC and
other key stakeholders regarding the electric reliability issue is inexcusable and that the EPA cannot
claim it has adhered to the statutory requirements of the CAA without installing all records related to
these consultations and permitting the public an opportunity to meaningfully comment. The commenter
asserts that given FERC's reservations about the EPA's portrayal of the situation, there is a glaring need
for more serious collaboration on this issue with an opportunity for public participation and that the EPA
must not sacrifice electric affordability and reliability at the feet of an arbitrary regulatory calendar.

According to the commenter, these are errors that are directly at odds with the rulemaking requirements
under section 307(d). The commenter states that under paragraph (d)(3), a "notice of proposed
rulemaking... shall be accompanied by a statement of its basis and purpose," and this statement "shall
include a summary" of the "factual data on which the proposed rule is based;" and the "methodology
used in obtaining the data and in analyzing the data," and that paragraph (d)(3) instructs that "[a]ll data,
information, and documents referred to in this paragraph shall be included in the docket on the date of
publication of the proposed rule." According to the commenter, the EPA has not followed these
statutory commands as the requirement to provide "all data" on which the proposal was based was not
included in the preamble nor in the docket at the time the proposal was published in the Federal
Register.

The commenter states that the D.C. Circuit Court of Appeals has held that the public notice and
comment requirements "are designed (1) to ensure that Agency regulations are tested via exposure to
diverse public comments, (2) to ensure fairness to affected parties, (3) to give affected parties an
opportunity to develop evidence in the record to support their objections to the rule and thereby enhance
the quality of judicial review." According to the commenter, these objectives have been undermined in
this rulemaking process, and there are indications in the preamble that regardless of the public input, the
EPA has a predetermined outcome in mind when it crafted these proposed regulations. The commenter
notes that the proposed rule states, ".. EPA expects that sources will begin promptly, based upon this
proposed rule, to evaluate, select, and plan to implement, source-specific compliance options" and that
the Court's holding highlights the issue of whether EPA's unreasonable timeframe will effectively
prevent the agency from being responsive to public comments.

Comment 57: Commenter 19114 believes that the EPA has not taken into consideration the impact of
upsets or variations in operation, process or fuel specification could have on reliability. Such conditions,
the commenter argues, could result in a unit having to be derated or taken offline to remedy the
situation. The commenter recommends that the EPA more thoroughly examine the impact of process
upsets on reliability of the electric supply.

Comment 58: Several commenters (17813, 17911, 17930) are concerned that the EPA has
underestimated the impact of rising demand on electric system reliability. Commenter 17813 argues that
even without the EGU MACT retirements, the Texas ERCOT grid will struggle to meet rising electricity
demand. They note that Texas is growing at a rate of 1,000 people a day, and that ERCOT anticipates
capacity shortfalls of at least 7,000 MW in 2015, 18,245 MW in 2020, and 50,000 MW in 2030 to
maintain a reserve margin of 13.75%. Commenters 17911 and 17930 note that the current electric power
market has significant excess capacity that is the result of power consumption cutbacks caused by a
stalled economy. If industry were to return to pre-2008 levels, they argue the market availability and
market demand would be more closely aligned, and even the EPA's estimated 9 GW retirement may
have an impact.

327


-------
Comment 59: Several commenters (17627, 18037, 18441) note that the EGU MACT has already had an
impact on coal-fired electricity generation. They note that 6,900 MW (11% of PJM coal capacity) did
not clear the recent PJM capacity market auction completed in May 2011. These commenters believe
that the coal plant offers, which included anticipated environmental compliance costs, likely did not
clear the market because they were high relative to demand response offers. They further assert that
capacity that does not clear in the PJM capacity market auction is likely to be retired and that they
expect a much higher percentage of coal capacity will not clear the 2015/16 capacity auction.

Comment 60: Multiple commenters (8443, 16705, 17400, 17761 17697, 17724, 17804, 17813, 17911,
17919, 17930, 18034, 18037, 18448, 18538, 19114) believe the EPA's analysis underestimates the
potential impacts on electric system reliability because the agency has failed to fully account for the
potential effects of other related, ongoing and or upcoming regulatory initiatives affecting the electric
generation sector, including more stringent NAAQS, upcoming emission guidelines for GHG emissions
(under NSPS as well as related PSD guidance), coal combustion residue (CCR) regulations, and
regulations under section 316(b) of the Clean Water Act (CWA) for cooling water intake structures.
Commenter 8843 worries that the "enormous" investments required to comply will lead to reliability
issues by closing down anywhere from 30-50% of coal-fired power plants. Commenter 17055 worries
that the EPA has not considered the impact of the RICE regulations that could potential result in the loss
of the small generators upon which many municipalities rely. They note that elimination of those units
could create local supply challenges.

Comment 61: Commenter 17725 argues that more time is need to comply with the rule because the
utilities that participate in the PJM and ISO-NE auctions have already made commitments to supply
power through May 31, 2015. They further note that the last date to submit a delist bid for ISO-NE for
PY 2015/2016 will have passed before the final EGU MACT is published.

Comment 62: Several commenters (17774, 17919, 18441) disagree with the EPA's statements that
reliability challenges related to early EGU retirements can be managed. Commenter 18441 believes the
RTO/ISO notification procedures are not adequate to meet the magnitude of changes and potential
retirements that could result from implementation of the proposed rule. Commenter 17774 states that
South Carolina does not have an RTO or ISO to assist in planning. This commenter believes that the
EGU MACT will cause long-range planning challenges and reliability concerns in the South Carolina,
because of the lack of RTOs and the significant shutdowns of coal plants in the southeastern U.S.
Commenter 17919 believes that the industry cannot rely on EPA emergency authorities because the EPA
and the U.S. DOE cannot agree on whether or not emergency orders actually forestall agency
enforcement actions. Commenter 19114 is concerned that the EPA has not yet consulted with DOE and
FERC and worries that the necessary rule coordination or harmonization is not occurring.

Response to Comments 52 - 62: The EPA has considered the concerns raised by commenters and has
concluded that given the flexibilities provided in the final rule, the requirements of the final rule for
existing sources can be met by most sources without adversely impacting electric reliability. In
particular, the EPA believes that the flexibility of permitting authorities to allow a fourth year for
compliance should be available in a broad range of situations (as discussed below), and that this
flexibility addresses many of the concerns that have been raised. Furthermore as indicated below, in the
event that an isolated, localized concern were to emerge that could not be addressed solely through the
1-year extension under CAA section 112(i)(3), the CAA provides flexibilities to bring sources into
compliance while maintaining reliability.

328


-------
The EPA considered the impact that potential retirements in response to this rule will have on resource
adequacy. In considering these impacts, the EPA considered both the analysis it has conducted as well as
analyses conducted by a number of other groups. The EPA's analysis shows that the expected
retirements of coal-fueled units as a result of this final rule (4.7 GW) are fewer than was estimated at
proposal and much fewer than some have predicted. Because concerns have been raised that the use of
DSI may not be as prevalent as the agency has predicted and because this could lead to more coal
retirements, the agency also performed a sensitivity analysis in which less DSI systems and more
scrubber systems were installed. In that sensitivity, we see approximately 1 more GW of retirement.

This small change would have only a very small potential impact on reliability. When considering the
impact that one specific action has on power plant retirements, it is important to understand that the
economics that drive retirements are based on multiple factors including: expected demand for
electricity, the cost of alternative generation, and the cost of continuing to generate using an existing
unit, e EPA's assessment looked at the capacity reserve margins in each of 32 sub-regions in the
continental U.S. Demand forecasts used were based on EIA projected demand growth. The analysis
shows that with the addition of very little new capacity, average reserve margins are significantly higher
than required. The NERC assumes a default reserve margin of 15 percent while the average capacity
margin seen after implementation of the policy is nearly 25 percent. Although such an analysis does not
address the potential for more localized reliability concerns associated with transmission constraints or
the provision of location-specific ancillary services (such as voltage support and black start service), the
number of retirements projected suggests that the magnitude of any local reliability concerns should be
manageable with existing tools and processes.

Several outside analyses have reached conclusions consistent with EPA's analysis. The DOE, in
December 2011, published a report that looked at resource adequacy in the bulk power system when
faced with a stress test which was a regulatory scenario far more stringent than EPA's regulations.10 For
this stress test, in addition to CSAPR and MATS requirements, each uncontrolled electric generator is
required to install both a wet FGD system and a fabric filter to reduce air toxics emissions. If such
installations are not economically justified, this scenario assumes that the plant must retire by 2015. In
reality, as discussed previously, power plant owners will have multiple other technology options to
comply with the regulations - options that typically cost less than installations of FGDs and fabric
filters. The analysis finds that target reserve margins can be met in all regions, even under these
stringent assumptions. Moreover, in every region but one (TRE), no additional new capacity is needed.
In TRE, the analysis finds that less than 1 GW of new natural gas capacity would be needed by 2015
beyond the additions already projected to occur in the Reference Case. This analysis also finds that the
total amount of new capacity that would be added by 2015 is less than the amount that is already under
development.

In August 2011, PJM Interconnection - the Regional Transmission Operator (RTO) responsible for
planning and reliable operation of the bulk power system serving all or portions of 13 states in the Mid-
Atlantic and Midwestern regions - issued a report analyzing the impacts of the CSAPR and the proposed
MATS rule.11 Although PJM's analysis assumes substantially more retirements than EPA projects, it
nevertheless concludes that resource adequacy is not threatened in the PJM region. This is particularly
significant, given that the PJM region is one of the largest and most heavily dependent on coal-fueled

10	U.S. Department of Energy, December 2011, "Resource Adequacy Implications of Forthcoming EPA
Air Quality Regulations".

11	PJM Interconnection, August 26, 2011, "Coal Capacity at Risk for Retirement in PJM: Potential
Impacts of the Finalized EPA Cross State Air Pollution Rule and Proposed National Emissions
Standards for Hazardous Air Pollutants."

329


-------
generation in the country. The PJM analysis notes, as EPA has acknowledged, that even where there is
adequate generation capacity on a regional basis, localized reliability issues may emerge in connection
with retirements that may need to be addressed.

In June 2011, the Bipartisan Policy Center issued a report analyzing potential collective impacts of
EPA's pending power sector rules and concluding that "scenarios in which electric system reliability is
broadly affected are unlikely to occur."12

The EPA has reviewed industry and NERC studies suggesting, contrary to the EPA's and these other
groups' analyses, that EPA rules affecting the power sector (including this final rule, the CSAPR, EPA's
proposed rule addressing power plant cooling water intake systems under section 316(b) of the Clean
Water Act (CWA), and EPA's proposed rule addressing coal combustion residuals under the Resource
Conservation and Recovery Act) will result in substantial power plant retirements. Some of these studies
predict that such levels of retirements will have adverse effects on electric reliability in some regions of
the country. Although the specifics of these analyses differ, in general they share a number of serious
flaws in common that call their conclusions into question.

First, most of these studies make assumptions about the requirements of the EPA rules that are
inconsistent with, and dramatically more expensive than, the EPA's actual proposals or final rules. For
example, a large proportion of the retirements projected by several of these studies is attributable to their
inaccurate assumption that EPA's cooling water intake rule under CWA section 316(b) would require all
or virtually all existing power plants to install cooling towers. In one study, the reliability effects
reported are based on inaccurate assumptions that all existing EGUs with a capacity utilization factor of
less than 35 percent would close, and that all in-scope electric generators would be required to install
cooling towers within 5 years, whereas the not-selected options with closed cycle cooling in EPA's
proposal envisioned that permit authorities could exercise discretion to allow facilities 10 to 15 years'
time to comply. In most cases, these analyses were performed before the CWA section 316(b) rule or the
MATS rule were even proposed; even analyses subsequent to the CWA section 316(b) proposal
continue to inaccurately portray EPA's proposed approach.

Second, in reporting the number of retirements, many analyses fail to differentiate between plant
retirements attributable to the EPA rules and older, smaller, and less efficient plants that are already
scheduled for retirement because owners have made business decisions, based in significant part on
market conditions, not to continue operating them.

Third, most of these analyses fail to account for the broad range of responses available to address
electric reliability concerns associated with power plant retirements, including upgrades to the
transmission system, construction of new generation, and implementation of demand-side measures.
These measures are discussed at greater length below.

As a preliminary matter, none of these situations, either alone or in combination, will necessarily lead to
an electric reliability problem. There is excess generating capacity in the U.S. today and in most cases an
EGU that closes, either temporarily until it comes into compliance or permanently, will not cause a
reliability problem. As explained above, our modeling of the impact of this final rule at the regional
level projects retirements of less than one percent of nationwide generating capacity and confirms that
there will continue to be adequate capacity in all 32 subregions of the country as sources comply with

12 Bipartisan Policy Center, June 2011, "Environmental Regulation and Electric System Reliability".

330


-------
the rule.13 This analysis shows that significantly less capacity will close in response to the final rule than
might have under the proposal. Moreover, the regional modeling of retirements demonstrates that plants
that close in response to this rule are spread out across the country rather than clustered in one area.
Outside analyses have identified many of the same flaws in studies projecting large-scale retirements as
a result of EPA's power sector rules. For example, On August 8, 2011, the Congressional Research
Service (CRS).14 issued a report that report that concluded that studies that assert that EPA rules will
cause reliability problems, often make assumptions about the requirements of the rules that are
inconsistent with, and dramatically more expensive than, the EPA's actual proposals. CRS further noted
that EPA's rues will primarily affect units that are more than 40 years old, that have not yet installed
state-of-the-art pollution controls, and that are inefficient. Many of these plants are being replaced by
combined cycle natural gas plants, driven more my lower gas prices than by EPA's regulations. The
June 2011 Bipartisan Policy Center report referenced above likewise highlighted many of these same
shortcomings in the studies in question15as did M.J. Bradley and Analysis Group in a June 2011
report.16

Comment 63: Numerous commenters (17402, 17403, 17689, 17697, 17705, 17730, 17734, 17736,
17757, 17758, 17761, 17770, 17800, 17808, 17813, 17815, 17817, 17820, 17821, 17868, 17877, 17881,
17925, 17931, 18016, 18021, 18024, 18033, 18424, 18430, 18433, 18442, 18447, 18498, 1850, 18502,
19032, 19114, 19121) note that there are likely to be delays due to permitting, which will likely increase
due to the volume of utilities complying with this rule.

Multiple commenters (17689, 17821, 17868, 17877, 17881, 18024, 18442) specifically reference the
NSR process.

Multiple commenters (17730, 17736, 17758, 17808, 17820, 17821, 18024, 18037, 18428, 18447, 19114)
specifically reference the PSD process.

Multiple commenters (17402, 17757, 17736, 17800, 17820, 17821, 18428, and 18502) are concerned
with the extra delay that FGD landfill permitting and building could cause.

Commenters 17821 and 18428 are specifically concerned with GHG permitting and an associated
BACT determination.

Commenter 18424 is concerned that utilities must have rate-payer financed capital investments approved
by state regulatory bodies, which can expand the compliance time by many months.

Commenter 17813 is concerned about pre-permit approval evidentiary hearings required in Texas,
which typically exceed 2 years in duration.

Commenter 18031 notes that Minnesota utilities must comply with the Minnesota Mercury Emission
Reduction Act of 2006 ("MERA"), which requires review by the Minnesota Pollution Control Agency.

13	See Technical Support Document on Resource Adequacy in this Docket.

14	James E. McCarthy and Claudia Copeland, Congressional Research Service, August 8, 2011, "EPA's
Regulation of Coal-Fired Power: Is a 'Train Wreck' Coming?".

15	Bipartisan Policy Center, June 2011, "Environmental Regulation and Electric System Reliability".

16	M.J. Bradley & Associates and Analysis Group, June 2011, "Ensuring a Clean, Modern, Electric
Generating Fleet while Maintaining Electric System Reliability."

331


-------
Commenter 18433 cites Guam's procurement laws and lengthy procurement process that may take
longer than the EPA's deadline would allow.

Commenter 19114 states that prior to beginning construction, some state regulations require obtaining
public utility commission approval in the form of a certificate of need.

Commenter 18450 asks that the EPA establish an expedited permitting process for those affected units
that require permit amendments to install HAP controls.

Response to Comment 63:

Permitting Process under the Clean Air Act can cause Delays

Some commenters thought that EPA permitting could cause delays in implementing this rule. The EPA
recognizes that, following the vacatur of the new source review (NSR) pollution control project
exemption in New York v. EPA, 413 F.3d 3, 40 41 (D.C. Cir. 2005), pollution control projects,
including pollution control projects constructed to comply with this rule, have the potential to trigger
NSR permitting. Based on an analysis done in 2005 that looked at SCR and FGD for CAIR compliance,
but that remains current and relevant for all pollutants except for GHG, EPA believes that NSR
requirements would not significantly impact the construction of pollution controls that are installed to
comply with this Rule. In addition it is very unlikely that pollution control projects would cause GHG
increases that would exceed the 75,000 tons per year threshold either as a result of either chemically
manufacturing GHGs or as a result of parasitic load. The EPA concludes therefore that there will be no
significant impacts on timing from NSR for any pollution control projects resulting from this rule.
Should NSR be triggered it would at most be for just a few of the projected control installations.. In the
limited circumstances where pollution control installations under the Mercury and Air Toxics Standards
may trigger NSR, we also note that an expedited permitting process can occur with sufficient time to
obtain permits and achieve emission reductions. For this reason, we strongly encourage permitting

State Requirements Can Cause Delays

Some commenters said that states may have laws and other requirements that will cause companies to
delay implementation of this rule. Some companies may construct replacement generation as a
compliance strategy. State pre-construction permitting requirements depend upon each individual state.
Some states do not require pre-construction permits while some others require public utility commission
(PUC) approval. For states obtaining PUC pre-approval for cost recovery, authorization typically
averages seven months and is obtained usually within one year.17 Furthermore, while PUC approval is
necessary to recover investment costs through rate payers, it is not a prerequisite for obtaining credit or
performing conceptual studies. EPA encourages all parties, state regulators, transmission operators, and
companies, to work together in a coordinated and reasonable effort to implement this regulation within
the compliance time frame. The EPA continues to believe, based on the analysis discussed at the
beginning of this section, that most, if not all, units will be able to comply with the requirements of this
rule within 3 years. The EPA also believes that making it clear that permitting authorities have the
authority to grant a 1-year compliance extension where necessary, in the range of situations described
elsewhere in this document, addresses many of the other concerns that commenters have raised.

17 "Public Utility Commission Report" March 31, 2011 by M.J. Bradley & Assoc LLC; web site:
http://www.epa.gov/ttn/atw/utilitv/puc study march2011.pdf

332


-------
Time frame for Compliance Is Too Short to Construct and Permit an FGD Landfill

As we have said elsewhere in this document, the compliance deadline allows sufficient time for
completing landfills for FGD solids disposal. For example, DP&L will construct a landfill within 18
months to accept wastes generated from Stuart and Killen stations scrubbers. The EPA notes, however,
that retrofitting units do not necessarily need to complete landfill construction ahead of commencing
operation of the retrofit to achieve cost-effective emission reductions under the Transport Rule
programs. Such a source may either utilize a completed portion of the newly permitted landfill under
construction, transfer waste off-site to a permitted landfill within the owner's fleet, or contract waste
removal (and disposal) services. For example, Dallman station subcontracts coal ash disposal at a local
abandoned mine. The EPA uses a disposal cost assumption of $30-$50 per ton for wet FGD, dry FGD,
and DSI controls, which the EPA developed in consultation with an experienced power sector
engineering firm.

EPA should Establish an Expedited Permittins Process

As explained above and in the Preamble to the rule, the EPA does not feel that a new expedited process
is necessary. If all parties work diligently and proactively, state permitting will not prevent facilities
from coming into compliance with this rule within the compliance period. If, however there is an
unexpected delay that could not be prevented by the facility's owner, the EPA expects the 1-year
extension of the compliance time to be available.

Comment 64: Multiple commenters (16705, 17055, 17701, 17725, 17400, 17608, 17724, 17775, 17791,
17812, 17815, 17834, 17868, 17868, 17868, 17887, 18441, 18497, 18500, 18023) argue that the EPA is
unrealistic about the ability of utilities and state or regional energy authorities to avoid electricity
reliability issues after the rule is implemented. These commenters believe the rule may result in the
shutdown of certain units that are critical to the reliability of electric supply on a timeline that is faster
than the time necessary to replace the power or upgrade transmission. Commenter 17608 notes that the
EPA's assumption that industry can comply quickly with the rule was a key assertion in the EPA's
conclusion that reliability will be unaffected.

These commenters identified several logistical problems that they believe may take longer to overcome
than the 3- to 4-year time period allowed by the rule. These include:

•	Time for coordination of offline time for the installation of pollution controls on several plants in
the same region.

•	Time to obtain access to natural gas pipelines for repowering or replacing a plant with a natural
gas generator.

•	Time for planning, building, and interconnecting transmission lines to replace retired EGU
capacity.

•	Time to construct new EGUs or other alternative energy sources.

These commenters argue that the time needed to design, procure and permit new control equipment
takes several years and that even if these steps could be accomplished in 2 years, there would
realistically remain only 6 months in the third year when control equipment installation can occur (i.e.,
during the spring and fall periods of reduced electricity demand). Commenter 17775 notes that
electricity demand is high the other 6 months of the years and that consequently most units must either
be online or on standby to meet demand peaks. The commenter argues that failure to have an adequate
number of EGUs available during this period could result in power curtailments or, in the worst case,

333


-------
brownouts or rolling blackouts. Commenter 17775 estimates that installation of new control equipment
required by the EGU MACT would take at least 6 years to complete.

Response to Comment 64: The EPA's authority for setting the compliance time frames is set out in the
CAA. In developing this proposed rule, the EPA has performed specific analysis to assess the feasibility
(e.g., ability of companies to install the required controls within the compliance time-frame) and
potential impact of the proposed rule on reliability. For that analysis entitled "An Assessment of the
Feasibility of Retrofits for the Toxics Rule" dated March 9, 2011, the EPA has projected the quantity of
each APC technology that may need to be newly retrofitted and in service by the compliance date(s).
The EPA used its IPM model to analyze which APC technologies would likely be used, and in what
quantities, to achieve compliance with the proposed Toxics Rule.

The EPA's assessment shows that a reasonable, moderately paced effort of the power sector and
supporting industry, including some early starts, would result in many of the needed retrofits being
installed by January 2015 with some needing up to an additional year. In order for all retrofits to be
completed by January 2015, most projects would have to start early and the sector would have to engage
in a more aggressive deployment program. In the event that individual projects cannot be completed by
the January 2015 statutory deadline for compliance, the CAA offers affected sources the opportunity to
apply for a 1-year extension.

Although the EPA assessed the ability to install the controls in 3 years (and determined that the controls
could be installed in that time-frame), this would require the control technology industry to ramp up
relatively quickly. The EPA also assessed a time-frame that would allow some installations to take up to
4 years. This time-frame is consistent with the CAA which allows permitting authorities the discretion to
grant extensions to the compliance time-line of up to 1 year. This time-frame also allows extra time for
staggered installation of controls at facilities that need to install technologies on multiple units.

Staggered installation allows companies to address such issues as scheduling outages at different units
so that reliable power can be provided during these outage periods or particularly complex retrofits (e.g.,
when controls for one unit need to be located in an open area needed to construct controls on another
unit). In other words, the additional 1-year extension would provide an additional two shoulder periods
to schedule outages. It also provides additional opportunity to spread complex outages over multiple
outage periods. The EPA believes that while many units will be able to fully comply within 3 years, the
4th year that permitting authorities are allowed to grant for installation of controls is an important
flexibility that will address situations where an extra year is necessary. The EPA expects that state
permitting authorities will make the fourth year available.

Comment 65: Commenter 17697 writes that the proposed rule is unrealistic about the ability of the
Guam Power Authority (GPA) to avoid electricity reliability issues in 2014 when compliance with this
rule begins. The commenter states that there will be a substantial impact on Guam's electric rates

Response to Comment 65: The EPA agrees that the unique considerations faced by non-continental
EGUs warrant a separate subcategory for units that use liquid oil-fired units in non-continental areas
such as those on Guam and has included such a subcategory in the final rule. At proposal, the EPA did
not have all of the data from liquid oil-fired units in non-continental areas (e.g., Guam, Puerto Rico) and
solicited comment on whether a subcategory should be established, based on the data to be received, for
non-continental oil-fired EGUs. The EPA has now received these late data and, based on those data, we
determined the emissions characteristics of the non-continental units were different, and, therefore, the
Agency is finalizing a non-continental subcategory for liquid oil-fired EGUs in Guam, Hawaii, Puerto
Rico, and the U.S. Virgin Islands. The EPA is not aware of any liquid oil-fired EGUs in any of the other

334


-------
U.S. territories that meet the CAA section 112(a)(8) definition but, if there are such units, they would
also be part of the non-continental subcategory.

The EPA agrees that the unique considerations faced by non-continental refineries, including a limited
ability to obtain alternative fuels that lead to different emissions characteristics, warrant a separate
subcategory for these EGUs. The EPA believes that units in this subcategory will comply through the
use of cleaner oils or, for PM, through the installation of an ESP.

Comment 66: Commenters 17724 and 17805 ask that the EPA take into consideration the advance
determination of prudence (ADP) process, which is a process to obtain concurrence from regulatory
commissions that its decisions on options (and required expenditures) for future energy resources and
modifications to existing energy resources are prudent. The commenters state that the ADP process, in
states where it is available, takes almost 12 months to complete and is a critical step for investor-owned
utilities seeking financing for modifications or new construction.

Commenter 17821 also mentioned prudency review by regulatory authorities.

Response to Comment 66:

Fiduciary Obligations Prevent Expenditures until Rule Finalized

Multiple comments claim initiating major capital expenses prior to the rule's promulgation violates a
public company's fiduciary obligations. In all cases, the comments fail to quantify financial burdens to
justify their position. A corporation's obligations go beyond fiduciary trust: they include civic
responsibilities for public (and employee) health, as well as accountability for future direction (as
determined by the board of directors). In response to these monetary assertions, the EPA recognizes the
adversity towards financial risks associated with installing controls equipment prior to rule
promulgation; however, the expenditures for determining compliance requirements (pre-award work)
are minimal. The EPA funded a study to update and improve retrofit control costs modeled within IPM
for the Cross-State Rule. From these studies, engineering and construction management costs (as a
percentage of total installed cost) range from 4.1% to 7.3% (basis: 500 MW unit). Considering industry
typically limits conceptual engineering not to exceed 10% of total engineered cost, by extension, pre-
award work accounts for less than 1% of total installed price. [Conceptual engineering studies are
defined as: establishing project scope, type of controls, control's performance, auxiliary equipment, and
permit plus funding requirements.] Since conceptual engineering is necessary to assess potential unit
modification options, the EPA believes these pre-award minor expenditures do not violate fiduciary
obligations; rather, they provide valuable planning information for future regulatory compliance. For
example, Nebraska Public Power District (NPPD) commissioned a $2.4 million study to develop a
"ready to issue" contract for an FGD retrofit estimated to cost $1 billion for the 1,365 MW Gerald
Gentleman Station.18 This represents 0.24% of installed cost. Since conceptual engineering is necessary
to assess potential unit modification options, the EPA believes that these pre-award minor expenditures
do not violate fiduciary obligations; rather, they provide valuable information for future planning for
regulatory compliance, which appears to serve a sensible fiduciary purpose.

Negotiating Contracts, Competitive Bid Evaluation - More Time Required for Compliance

18 "S&L to Develop Cost Estimates, Plans for FGD at Gerald Gentleman"; Utility E-Alert #1030, June
24, 2011; Mcllvaine Company

335


-------
Contract negotiation through the competitive bid process is an agreement achieved between a buyer
(utility) and seller (supplier). Ultimately, the buyer determines length of time spent in negotiation, and
concludes negotiations by signing an award for goods and/or services.

Owner's Decisions & Options

Citing procedural difficulties (interfacing with multiple entities, meeting once a year, etc.) do not
constitute sufficient basis for inability to meet compliance dates. The owner is ultimately responsible for
assuring adequate and timely compliance by exercising imitative over a "business as usual" approach.
Moreover, MATS is inherently flexible - it allows an owner multiple options to attain compliance
deadlines; namely, purchase power, shift power generation to cleaner units (combined cycle plants,
stations with emission controls, etc.), expedite retrofit work (utilize multi-shift schedule or extended
overtime), fuel switching/blending, upgrade existing equipment, replace equipment/components, and
retrofit existing equipment - or any combination there-of.

Comment 67: Multiple commenters (18023, 17608, 17638, 17716, 17752, 17756, 17820, 17821, 17840,
17868, 17904, 17925, 17931, 18033, 18502) have concerns with "early planning" and "forward
planning" recommended by the EPA. Commenter 18023 notes, "If EPA intended this to be a direct final
rulemaking, it should have said so."

Commenter 17911 states that municipalities may not make any significant financial or operational
changes before the rule is promulgated, otherwise, they may be violating their fiduciary responsibilities.

Commenters 18428 and 19114 state that it would be imprudent planning for utilities to commit capital
without knowing what the final standards are, as the risk of penalties and uneconomic investments is too
great. The commenters state that more fundamentally, utilities contemplating retrofits to generating units
in rate-regulated states such as those in which the commenter operates run a substantial risk of non-
recovery if they make capital commitments before a final rule is issued.

Comment 68: Commenter 18421 recommends that the EPA, the DOE, and the FERC work closely with
regional utility planning and operation centers, the National Association of Regulatory Utility
Commissions, state PUCs, and utilities to ensure that the measures available preserve the reliability of
the electric system.

Commenter 17741 is concerned that the compliance time will not allow adequate prep time, causing
utilities to shutter multiple units or entire plants. The commenter is concerned about job loss.

Response to Comments 67 and 68: In the preamble to the proposed rule, the EPA urged power
generators and others to perform advanced planning so as to be prepared to implement the regulation in
the 3-year compliance timeframe. A number of commenters took exception to that. Many stated that
they can't begin planning until they know what the rule is for certain. Others said that they were in fact
doing that planning so that they would be able to comply within the compliance timeframe.

In the MATS preamble, the EPA stated that, although there are a significant number of controls that
need to be installed, with proper planning, we believe that the compliance schedule established by the
CAA can be met. The EPA pointed out that there are already tools in place (such as integrated resource
planning, and in some cases, advanced auctions for capacity) that ensure that companies adequately plan
for, and markets are responsive to, future requirements such as the rule. In addition, the EPA itself is
reaching out to key stakeholders including not only sources with direct compliance obligations, but also

336


-------
groups with responsibility to assure an affordable and reliable supply of electricity including state Public
Utility Commissions (PUC), Regional Transmission Organizations (RTOs), the National Electric
Reliability Council (NERC), the FERC, and DOE. The EPA intends to continue these efforts during the
implementation of this rule. It is the EPA understands that FERC and DOE will work with entities
whose responsibility is to ensure an affordable, reliable supply of electricity, including state PUCs,
RTOs, the NERC to share information and encourage them to begin planning for compliance and
reliability as early as possible. This effort to identify and respond to any projected local and regional
reliability concerns will inform decisions about the timing of retirements and other compliance strategies
to ensure energy reliability. The EPA believes that the ability of permitting authorities to provide an
additional 1 year beyond the 3-year compliance time-frame as specified in CAA section 112, along with
other compliance tools, ensures that the emission reductions and health benefits required by the CAA
can be achieved without any risk of adverse impacts on electricity system reliability.

Comment 69: Several commenters (17403, 17716, 17821, 17902) note that delays are expected due to
the number of involved stakeholders (state public utility commissions, RTOs, NERC, FERC, DOE,
EPA).

Response to Comment 69: Some commenters thought that there would be delays in compliance with
this rule attributed to the numerous stakeholders who would be involved. With proper planning, we
believe that the compliance schedule established by the CAA can be met. As stated above, there are
already tools in place (such as integrated resource planning, and in some cases, advanced auctions for
capacity) that ensure that companies adequately plan for, and markets are responsive to, future
requirements such as the proposed rule. In addition, the EPA itself is reaching out to key stakeholders
including not only sources with direct compliance obligations, but also groups with responsibility to
assure an affordable and reliable supply of electricity including state Public Utility Commissions (PUC),
Regional Transmission Organizations (RTOs), the National Electric Reliability Council (NERC), the
FERC, and DOE. The EPA intends to continue these efforts during the implementation of this proposed
rule. The EPA understands that FERC and DOE will work with entities whose responsibility is to ensure
an affordable, reliable supply of electricity, including state PUCs, RTOs, the NERC to share information
and encourage them to begin planning for compliance and reliability as early as possible. This effort to
identify and respond to any projected local and regional reliability concerns will inform decisions about
the timing of retirements and other compliance strategies to ensure energy reliability. The EPA believes
that the ability of permitting authorities to provide an additional 1 year beyond the 3-year compliance
time-frame as specified in CAA section 112, along with other compliance tools, ensures that the
emission reductions and health benefits required by the CAA can be achieved while safeguarding
completely against any risk of adverse impacts on electricity system reliability

Comment 70: Several commenters (17402, 17752, 17758, 18428, 19114) note that the word "installed,"
when attributed to vendors, refers only to the physical construction of the controls but that the reality of
control technology installation includes more than that.

Comment 71: Several commenters (17403, 17756, 17820, 17931) ask for additional time to allow for
unit/control device testing/optimization after installation.

Response to Comments 70 and 71: The EPA is aware that installation of controls means more than
simply manufacturing the device but means that it is installed on the unit.

Comment 72: Commenters 18430 and 18023 note that interstate gas pipelines may need to be expanded
to account for EGU fuel supply changes.

337


-------
Response to Comment 72: The EPA's analysis does not fully support this contention. The use of
natural gas to comply with this regulation does increase modestly, by about 3% in 2015. However
natural gas generation in 2015 with this rule will be more than 200,000 GWh less than generation from
natural gas in 2009. This indicates that the shift to natural gas for compliance with this rule would be
very modest and that it could be accomplished mostly with existing capacity.

Comment 73: Commenter 17815 notes that the short compliance timeline will jeopardize fuel diversity.

Commenter 16850 states that over the past 20 years, the vast majority of new capacity additions in
Florida have been natural gas-fired. The proposed Air Toxics rule, the recent Cross-State Air Pollution
rule, potential greenhouse gas regulations, and currently low gas prices may further encourage utilities to
install natural gas-fired generation or repower existing oil- or coal-fired capacity to natural gas as a
compliance strategy. In order to provide Florida's consumers with the benefits of a balanced fuel mix,
utilities should be allowed to retain existing coal capacity without installing costly air compliance
measures, if the utility commits to retire or repower the unit in the near future.

Commenter 17887 states that the EPA should recognize the needs of each state and region to deploy a
portfolio of cost-effective supply- and demand-side resources based on unique circumstances - Over the
past twenty years, the majority of new capacity additions in Pennsylvania have been natural gas-fired.
Many states in the PJM footprint including Pennsylvania are actively encouraging the development of
renewable resources such as wind and solar. In order to provide Pennsylvania customers with the
benefits of a balanced fuel mix, generators should be allowed to retain existing coal capacity without
installing costly air compliance measures, if the generator commits to retire the unit in the near future
due to the availability of "cleaner" generation resources. Further, the EPA should retain the limited use
provision that appears to allow generators to avoid installing costly controls on units that are rarely
dispatched.

Comment 74: Several commenters (16549, 17403, 17682, 17917) are concerned that the rule will
weaken reliability by removing coal-fired units as a resource. Commenter 16549 believes that that the
EGU MACT may make it impossible to utilize the U.S.'s vast supply of coal. Commenter 17917
believes the proposed rule threatens both existing facilities and future development of coal-fired EGUs.
Commenter 17682 believes that the EPA is intentionally trying to increase the compliance costs for
coal-fired plants to force coal plants to either close or be replaced by other sources, such as gas-fired
EGUs and renewable energy alternatives (solar, wind, biofuels). This commenter believes the EGU
MACT amounts to a subsidy of alternative energy industries and is defacto tax on the public.

Commenter 17403 coal-fired retirements would have a significant impact on key midwestern and south
Atlantic states.

Comment 75: Commenter 17386 expresses concern that the proposed rule would decrease generation
capacity by forcing early retirement of oil-fired EGUs. This commenter believes that forcing early
retirement of oil-fired EGUs and the consequential decrease in generation capacity and system reliability
is contrary to NERC's objective to provide reliable service.

Comment 76: Several commenters (17701, 17791, 17807) are concerned that environmental regulations
for EGUs will drive electric generators to a single fuel source, which they argue could unintentionally
weaken the stability of the power sector and increase cost for consumers. Commenter 17807 believes
that the EGU MACT may result in electricity supply problems in Florida because the state is a
peninsula, which limits opportunities to import power. The commenters note that fuel diversity is critical
for electricity reliability in Florida, where supply problems may be particularly acute during extreme

338


-------
weather events like the recent cold snaps and hurricanes, when supply of natural gas may not be
available for sustained periods of time.

Comment 77: Commenter 16850 notes that significant controls would be necessary at many of
Florida's coal- and oil-fired generating units, and some units would be at risk of retirement. The
commenter states that the EPA's final rules should avoid compromising electric system reliability and
allow the maximum compliance flexibility for electric utilities provided for under the CAA.

Commenter 18500 states that the EPA has also asserted that fuel switching of existing EGUs to natural
gas and construction of new gas-fired generating units can replace the retired coal units but that the
planning, contracting, permitting, financing and construction take longer than the restrictive timeframe
proposed, and during that timeframe, some units are not available for dispatch. The commenter states
that not all units will have ready access to sufficient gas supply to repower resulting in necessary gas
transmission upgrades that can be time consuming and costly. According to the commenter, the reality is
that the EPA's own permitting rules present a time consuming obstacle to meeting the EPA's deadline
yet nowhere in the proposal does the EPA contemplate addressing accelerated permitting for pollution
controls or exemptions from NSR requirements when making pollution control upgrades.

Response to Comments 73-77: The EPA does not dictate the compliance strategy that might be used
by regulated companies. The EPA has carefully designed a rule that can be achieved by all coal types.
Although the EPA's analysis indicates that most plants will comply by retrofitting existing coal-fired
plants with pollution controls, some may switch to cleaner fuels. Our analysis shows that in fact there is
very little difference in the relative use of the three major coal ranks with and without the rule in 2015.
There is a slight increase in the use of interior bituminous coal and a slight decreases in the use of
subbituminous and lignite coals. Over all, coal remains the most important fuel for electricity
generation.

Some plants may retire. In most cases there is adequate excess capacity to avoid any threat of a problem
for electricity reliability. Should there be a reliability concern, it can be addressed in a variety of ways
including use of excess capacity, installation of new capacity, transmission upgrades, and demand-side
strategies that can make over all compliance with this regulation much less expensive, and can be
implemented relatively rapidly. The EPA projects that this rule will result in a very small increase in
gas-fired generation, a very small decrease in coal-fired generation as a result of compliance with
MATS.

Comment 78: Commenter 17732 is concerned about the time it takes to receive land use approvals on
Indian trust lands should site-specific constraints necessitate use of additional land.

Response to Comment 78: Sources can obtain an additional year to comply if necessary for the
installation of controls. Unavoidable delays in obtaining permits necessary to install the controls would
likely be sufficient to obtain the additional year to comply.

Comment 79: Commenter 17738 is concerned about plants which already have emissions controls and
limitations established through case-by-case MACT determinations. The commenter suggests alternate
compliance dates for these plants.

Response to Comment 79: Sources that are existing sources on the compliance date for the final rule
would have 3 years to come into compliance. Generally these are newer plants that have pollution
controls and should be well positioned to comply with this regulation.

339


-------
Comment 80: Commenter 17386 recommends that the EPA and generation owners collaborate to
develop and meet timelines while monitoring equipment installation to avoid negative impacts of delays
that could occur. According to the commenter, such an approach would also ease concerns over grid
security caused by mass outages on generators to install the required equipment

Response to Comment 80: The EPA's analysis does not confirm that MATS will result in anywhere
near the extent of outages that this commenter projects, and several outside analyses have reached
conclusions consistent with the EPA's analysis. The EPA does agree, however, with the commenter that
a collaborative approach between the companies, the EPA, state regulators, RTOs and others involved in
assuring grid stability would help to assure grid security.

Comment 81: Commenter 17930 stated that the EPA's beyond-the-floor analysis [for Hg at facilities
burning virgin low BTU coal] does not properly take into account the effect that the limit would have on
energy requirements and reliability when lignite units are closed due to inability to meet the proposed
beyond-the-floor limit.

Response to Comment 81: As stated elsewhere, the EPA believes that the data used to conduct the
beyond-the-floor analysis are consistent with results achieved in U.S. DOE Hg control technology
demonstration projects. The DOE's National Energy Technology Laboratory (NETL) sponsored a
project entitled "Mercury Control for Plants Firing Texas Lignite and Equipped with ESP-wet FGD". In
this project, URS Group evaluated sorbent injection for Hg control in an 85/15 blend Texas lignite/PRB-
derived flue gas. The authors of the final project report noted that, in short term parametric tests, three
different brominated sorbents performed similarly with results indicating that 90 percent reduction of Hg
was attainable at injection rates of 2 to 3 pounds per million actual cubic feet (lb/Macf) and greater than
90 percent at higher rates. In longer-term (60-day) testing using a brominated sorbent, Hg removal
averaged 80 percent at a modest injection rate of 2 lb/Macf. This compares favorably to the results of 70
to 90 percent achieved in the short-term testing at the same injection rates. However, greater than 90
percent could have been achieved at injection rates of 3 to 5 lb/Macf. Note that all of these results are for
control across a cold-side ESP. Control across a fabric filter is normally expected to exceed that
measured through an ESP. The EPA believes that its beyond-the-floor analysis is appropriate, including
the costs analyzed. We do not anticipate any reliability problems due to lignite plants closing. Any shift
away from lignite is made up for by other types of generating capacity and shifts to PRB.

Comment 82: Commenter 18033 said that the EPA has committed a "fundamental error" with its
"undocumented and unsupported claims of key stakeholder collaboration to 'safeguarding] completely
against any risk of adverse impacts on electricity system reliability'." The commenter could not find
evidence of these consultations in the rulemaking docket.

Response to Comment 82: The docket will include documentation of all substantive meetings with
persons outside of the executive concerning this rulemaking.

Comment 83: Several commenters (17627, 18034, 18037, 18907) are concerned that the reduced
reliability resulting from the EGU MACT may result in an increase in emissions because industry will
be forced to rely on small emergency generators. These commenters note that most of the emergency
generators are small diesel-fired units that are not capped or in many cases permitted. The commenters
note that higher emissions from these emergency back-up generators are not normally a concern because
of their limited use during emergency situations and power outages. According to the commenters, if
demand response programs become a necessary strategy to prevent or minimize the impact of reliability
issues resulting from loss of capacity, however, then localized net increases in emissions would be

340


-------
expected. Rather than improving air quality, the commenters argue that this rule would directly and
adversely impact citizens in the urban cores where emergency generation is typically located.

Commenter 18037 stated that in its analysis of this year's capacity auction results, PJM noted that the
coal plant offers which included anticipated environmental compliance costs, likely did not clear the
market because they were high relative to demand response (DR) offers. According to the commenter,
this raises an important environmental contradiction and an issue that the EPA should consider in it cost
-benefit analysis. The commenter states that ISO-RTO estimates that are available suggest that 50% or
more of DR resources in the market are not demand reductions, rather they are merely a shift to
customer-supplied behind-the- meter generation, and much of that generation is from small diesel units
the emissions from which are not accounted for and in many cases not permitted. According to the
commenter, this is particularly important on very hot, 'high electric demand days" when DR generators
are called upon. The commenter states that as the EPA was informed by the State of Delaware in the
RICE NESHAP docket (EPA-HQ-QAR-2008-0708), there are tens of thousands of these diesel
generators throughout the Northeast.

According to the commenter, these "area sources" emit air toxics and are an increasingly significant
contributor to the ground level ozone non-attainment problem as DR programs continue to grow
exponentially; they represent tens of thousands of megawatts in the PJM, ISO-New England, New York
ISO, Midwest ISO wholesale markets and throughout the US. The commenter states that at a minimum,
since EGU units are clearly being displaced in the competitive markets by DR offers, and will not likely
be replaced megawatt-for-megawatt by cleaner, more expensive thermal generation which must control
and account for its emissions, the EPA's cost-benefit analysis is incomplete if it does not account for the
growth in emissions from behind-the-meter generation participating in ISO-RTO DR programs,
particularly those from uncontrolled diesel units.

Response to Comment 83: Not all demand response is a reduction in electricity demand, much of it
shifts demand for electricity from peak demand periods to periods of lower demand thus reducing the
need for peaking capacity. The commenter is talking about a use of generation from small diesel units
during periods of peak demand. These units, not subject to this regulation, and may be responsible for
increases emissions of pollution. The Reciprocating Internal Combustion Engine rulemaking which was
final in March of last year, but which is under reconsideration, limits the operation of these sources,
specifically to prevent an increase in emissions. These generators are less efficient to operate than other
sources and thus are less desirable economically as well as environmentally. The EPA does not expect
that the Mercury and Air Toxics Standards rule will substantially increase the use of these generators.

Comment 84: Commenter 18538 believes that the EPA has overstated the amount of generation
available in future years by more than 10 GW by including generating plants that have retired and by
failing to adjust wind generating capacity to account for the fact that wind is variable and often does not
blow during times of peak energy use.

Response to Comment 84: The EPA disagrees with the claim that it does not account for the variability
of wind generation in its power sector modeling projections. The EPA recognizes that wind is a variable
resource for power generation, and our modeling of MATS in fact takes this reality into account in a
very detailed manner to simulate future generation from wind turbines. The EPA's power sector
modeling utilizes capacity factors for wind generators that reflect both wind class (ranging from class 1
to class 7) and geographic region, and are explicitly designed to represent how often the wind blows to
support power generation at different locations. The EPA worked with the U.S. Department of Energy's
(DOE) National Renewable Energy Laboratory (NREL) on a complete update of the wind resource

341


-------
assumptions for use in EPA's IPM v.4.10. The result is a complete representation of the potential
onshore, offshore (shallow and deep) wind generating capacity (in MW) broken into four cost classes in
each IPM model region.

To represent intermittent renewable generating sources like wind and solar, the EPA's IPM modeling
(including the modeling used for MATS compliance cost projections) uses generation profiles which
specify hourly generation patterns for a representative day in winter and summer. Each eligible model
region is provided with a distinct set of winter and summer generation profiles for wind, solar thermal,
and solar photovoltaic plants, such that projected generation from intermittent renewable sources would
reflect the frequency that those resources are actually available in that region. The EPA derived its
capacity factor assumptions for wind generation from the Energy Information Administration's (EIA)
Annual Energy Outlook (AEO) 2010. They are shown in Table 4-20, Table 4-21, and. Table 4-22 of the
IPM documentation on EPA's website. See IPM documentation.

Comment 85: Several commenters (17800, 17807, 17911) believe that the work practice standards will
impact the reliability of electric supply. These commenters argue that most EGUs do not have annual
planned outages that would allow time for implementing the work practice standards. Commenter 17800
states that most planned outages are more than 18 months apart and planned major outages are typically
3 to 5 years apart. The commenter further notes that by requiring outages every 18 months, the EPA will
increase the number of outages and thus unit downtime. The commenter notes that inspections of
burners for coal fired units require an internal boiler inspection, which means that an outage of at least
15 days will be required (with 1-2 days to cool; 5 days to erect scaffolding; 2-5 days to repair or replace
burner components; 3 days to dismantle the scaffolding). According to the commenters, additional time
may also be required to order replacement parts, which could result in an extended outage of between 16
to 26 weeks.

Response to Comment 85: The EPA does not believe work practice standards will impact reliability
and notes that the frequency of the tune-ups required have been changed in the final rule. See Preamble
discussion of work standards.

8. Survey of public power utilities.

Comment 86: Commenter 17868 shared results from a survey it conducted of public power utilities
(utilities owning approximately 14 GW of coal based generation capacity responded to the survey).
According to the commenter, these represent over 50% of the coal-based capacity wholly owned by
public power utilities, and respondents ranged in cumulative capacity between 55 MW and 2200 MW,
and averaged 610 MW of coal based capacity):

a.	About 20% of respondents planned to retrofit FGD and about 20% SCR (typically the same utilities
were retrofitting both). About one-half planned to replace or supplement existing ESPs with new FFs

b.	About one-fourth were moving forward with plans based on the notice of proposed rule (NOPR).

c.	Half were waiting until the final rule is promulgated, and the rest intended to wait until other pending
environmental rules were finalized before deciding on a compliance approach.

d.	About three-fourths of respondents stated that they needed the assistance of engineering consultants
for planning their compliance strategy. Such reliance is not unusual, even for IOUs, but several
respondents cited their small size and/or remote locations as barriers to obtaining assistance from the

342


-------
larger, more qualified consulting firms. Additionally, several respondents cited a mandatory —public
bid process for selecting contractors (and purchasing equipment) which deterred some contractors and
created additional delays in reaching compliance.

e.	Public power utilities generally must receive approval from political bodies, such as an elected Board
of Directors and a City Council. Procedures vary by utility, but separate government approvals may be
required for the compliance plan and the issuance of bonds to pay for the compliance projects. Several
respondents noted that a public referendum is required in order for bonds to be sold.

f.	Planning periods averaged 17 months, and financing 8 months. However several respondents noted
that budgets were addressed only once per year, and that public reviews of plans and funding could
result in extended delays, including what one respondent called "hostile interventions."

Response to Comment 86: The EPA recognizes that many plants that are owned by public power
authorities are well controlled and, thus, are well positioned to implement this rulemaking. Some of
them, however, may have challenges privately owned facilities do not have. We think that the
flexibilities that are offered under the CAA including the availability of a fourth year and other
compliance time flexibilities will ease the burden these facilities face.

9. Other.

Comment 87: Commenter 18027 notes that the language in section 112(i)(3) is inconsistent across
paragraphs. Section 112(i)(3)(B) provides for a one-year source-specific extension to the principal
compliance schedule established for the source category or subcategory whereas the preceding
paragraph states that Congress provided for the compliance schedule established upon promulgation of
the standards to apply to an entire category or subcategory of sources.

Response to Comment 87: The EPA does not agree with the commenter that the CAA section 112(i)(3)
paragraphs are inconsistent. CAA section 112(i)(3)(A) authorizes the EPA to provide up to 3 years for
initial compliance with promulgated standards, and section 112(i)(3)(B) allows the EPA or a state with
an approved title V permit program to approve a 1-year extension of the compliance period established
in the final rule if such time is necessary for the installation of controls.

343


-------
5C02 - Compliance: Emissions Averaging

Commenters: 17174, 17402, 17623, 17627, 17648, 17655, 17689, 17691, 17705, 17714, 17716, 17718,
17719, 17722, 17725, 17730, 17731, 17736, 17737, 17740, 17757, 17758, 17768, 17774, 17775, 17789,
17795, 17798, 17800, 17813, 17816, 17818, 17820, 17821, 17856, 17870, 17873, 17877, 17881, 17885,
17902, 17904, 17913, 17928, 18014, 18024, 18025, 18031, 18037, 18429, 18449, 18450, 18498, 18539,
19114, 19120, 19121, 19214, 9738, 19536/19537/19538, 18023

1. Opposition to emission averaging compliance option.

Comment 1: Commenter 17174 states the emissions caps for existing affected sources choosing to
demonstrate compliance by the emission averaging option cannot be effectively implemented or
enforced. The commenter encountered many problems with the approval process in the vacated
Boiler MACT in 2007, and now the EPA has proposed the same approval process here for the Utility
MACT, disregarding the known problems in implementing the emission averaging compliance option
from the Boiler MACT. The commenter stated the emission cap should be included in the compliance
calculations. The commenter believes that the requirement to establish an emission cap and submit an
implementation plan to the permitting agencies for approval is problematic as written. The commenter
states that because the emission cap is not used in the initial compliance demonstration or in
demonstrating continuous compliance with the emission averaging option, the commenter states it is of
little use. The commenter states that if the intent of this option is for facilities to not exceed the cap at
any time, then the EPA should include a demonstration methodology that shows that a facility is not
exceeding the cap in the compliance equations in section 63.10009. According to the commenter, if the
cap is included in the compliance equations, facilities could certify compliance with the cap in
the NOCS and within each required semiannual report. The commenter went on to say that if the initial
and continuous compliance measures include the emission cap, the implementation plan will not be
necessary and states will not have to spend valuable time and resources to approve these duplicative
plans.

Response to Comment 1: The agency disagrees with the commenter's suggestion that the emissions
averaging option cannot be implemented or enforced effectively. The commenter's concerns regarding
emissions averaging plan approval is mistaken, as such an approval is required only if requested by the
Administrator. While the plan may not need to be submitted for approval, the EGU owner or operator
who wishes to use emissions averaging will need to develop, maintain, and make available a plan.
Emissions from EGU units included in averaging, as opposed to individual EGU units, are not to exceed
the otherwise applicable emissions limit. Deviations from meeting this requirement are already required
to be submitted in notices of compliance status (NOCS), so no rule change is needed. Finally, states,
local, or tribal agencies who are delegated the authority to implement this program will decide based on
their own needs and requirements whether or not to choose to require submission and approval of plans.

Comment 2: Commenter 17818 opposes the averaging of HAP. However, the commenter supports
allowance of limited emission averaging for existing units at sources that are within a single
subcategory. Commenter further states that without averaging their existing units are already below
existing HAP emission rates due to previous emission control projects, some of their units will be above
new HAP emission rate limits and would require redesign of the existing controls to achieve unit-
specific compliance. According to the commenter, averaging of units might facilitate state-of-the-art
highly effective controls installation on other units at the source to achieve an approved averaging plan,
and this may relieve the need to replace or modify controls that had been recently installed, in effect
giving credit for the installation of those controls.

344


-------
Response to Comment 2: The agency agrees with the commenter that emissions averaging can provide
a cost-effective, if not cost-saving, means of compliance, to EGU owners or operators. The emissions
averaging provisions of the rule remain.

Comment 3: Commenter 18450 opposes allowing owners and operators of existing affected sources to
demonstrate compliance by emissions averaging for units at the affected source that are within a single
subcategory since it will allow large facilities to avoid installing air pollution controls to reduce HAP
emissions on all affected units. Commenter recommends that the EPA remove the averaging provisions
and establish a discount factor to compensate for the measurement variability inherent in stack testing
for HAP.

Response to Comment 3: As mentioned in an earlier response, the agency supports the use of emissions
averaging for existing sources for a number of reasons, ranging from increased flexibility to reduced
costs for EGU owners or operators, as well as reduced emissions through use of a discounted emissions
limit for those units subject to emissions averaging. The EPA disagrees that use of a discount factor is
needed for this rule, as stack testing variability has already been incorporated in the rule's emissions
limits via use of the UPL calculation.

Comment 4: Commenter 19214 opposes the proposed average emission limits among multiple sources
at facilities in the Best Available Retrofit Technology (BART) program. The commenter states that even
though it appears to satisfy the criteria established by the EPA, in practice, it works only if all affected
sources operate exactly as assumed in the formulation. According to the commenter, realistically, the
better-controlled source may operate less than assumed (perhaps due to the greater costs of compliance),
while the under-controlled source uses cost advantage to operate more than assumed. Commenter
believes that the risks that actual emissions and potential human health and environmental effects will be
greater than assumed, and not worth providing more flexibility to emit hazardous air pollutants.

Comment 5: Several commenters (19536, 19537, 19538) states that the EPA should not permit units to
average emissions. According to the commenters, the proposed averaging would allow some coal- and
oil-fired units to emit HAP in excess of the promulgated standards (so long as a neighboring unit
operates below the standards) - a result prohibited by section 112. The commenters state that section
112 states that "[ajfter the effective date of any emissions standard . . . promulgated under this section
and applicable to a source, no person may operate such source in violation of such standard" unless the
agency provides a more lengthy compliance schedule. 42 USC section 7412(i)(3).

The commenters point out that the agency's discretion to construe the word "source" under the CAA is
constrained by the congressional policies underlying section 112. Chevron, U.S.A. v. Natural
ResourcesDef. Council, 467 U.S. 837, 866 (1984). The commenters state that Congress intended, in
section 112, to ensure the maximum reduction of hazardous air pollution, and to that end, it constrained
the agency's ability to balance pollution-reduction with economic considerations. See 42 USC section
7412(d). The commentesr assert that the agency has set most standards at the statutory minimum.
According to the commenters, section 112 does not allow the agency to permit additional pollution in
order to ease compliance (see 40 CFR section 63.41 (sources may not average emissions to avoid
compliance with section 112 standards).

Response to Comments 4 - 5: As mentioned earlier, while the agency has reviewed the commenter's
concerns, the agency finds emissions averaging when coupled with appropriate safeguards such as those
contained in the rule, including eligibility (existing units within a single subcategory) and frequent
emissions verification (quarterly) can provide a flexible, cost-effective compliance approach.

345


-------
2. Support emissions averaging compliance option.

Comment 6: Numerous commenters (17402, 17623, 17648, 17655, 17705, 17716, 17718, 17722,
17725, 17758, 17774, 17798, 17870, 17873, 17904, 17928, 18025, 18031, 19121, 18023) support
emissions averaging for compliance.

Response to Comment 6: The agency appreciates the commenters' support for use of emissions
averaging subject to the rule's eligibility requirements.

Comment 7: Commenter 17174 requests the EPA eliminate the requirement for delegated authorities to
approve implementation plans and instead develop an emission averaging certification mechanism
within the Notice of Compliance Status (NOCS), because the NOCS process is established, and states
have experience implementing it.

Response to Comment 7: As mentioned earlier, the rule allows, but does not require, delegated
authorities the ability to approve emissions averaging plans.

Comment 8: Commenters 17402 and 17648 note that emission averaging provides a flexible approach.
Commenters also note that emission averaging achieves equivalent MACT emissions limits.

Commenter 17402 states that facility-wide averaging will allow owners and operators to comply with
emissions limits by over controlling sources within the group where it is cost effective to do so in order
to offset exceedances of the standard by sources for which emissions control would be less cost
efficient.

Response to Comment 8: The agency appreciates the commenters' support for use of emissions
averaging subject to the rule's eligibility requirements.

Comment 9: Commenter 17174 states the requirement for delegated agencies to approve
implementation plans is burdensome and unnecessary. The commenter suggests the EPA should provide
specific guidance and examples on what constitutes an acceptable emission cap. The commenter notes
that while the EPA attempted to correct the enforceability problem related to the emission cap in the
final Boiler MACT by requiring facilities to report the emission cap in the NOCS (see 40 CFR
63.7545(e)(5)(i)), and certify compliance with the cap in the compliance reports (see 40 CFR
63.7550(c)(13)), there is no guidance or clear process on what constitutes an acceptable and enforceable
emission cap that delegated agencies can follow to approve the cap. If the EPA decides that the
submittal and approval of implementation plans are necessary for the emission averaging compliance
option, the commenter believes that the EPA should retain the authority to approve the implementation
plans.

Response to Comment 9: The agency finds the commenter's concern misplaced. While the rule allows
state, local, or tribal authorities who have been delegated approval of this rule the ability to require
submission of, as well as approval of, emissions averaging plans, the rule requires EGU owners or
operators who choose to engage in emissions averaging to develop an emissions averaging plan and to
maintain and present such a plan upon request. The rule establishes the formula for demonstrating
compliance when emissions averaging is used, so there is no need for additional guidance. Should the
commenter find developing a plan or determining compliance to be problematic, he or she could choose
another compliance option available in the rule.

346


-------
Comment 10: Commenter 17174 suggests the emission averaging compliance option in the
Boiler MACT and Utility MACT be consistent.

Response to Comment 10: The agency agrees with the commenter's suggestion, and the rules are
consistent to the extent possible.

Comment 11: Commenter 17798 states that both emissions averaging and staging controls provides
flexibilities for utilities having to meet a new stage of reductions under the Cross State Air Pollution
Rule (CSAPR).

Comment 12: Commenters (17870, 17873) state that emissions averaging represents an equivalent,
more flexible, and less costly alternative to unit-by-unit emissions limits while still maintaining a
regulation that is workable and enforceable. According to the commenter, this flexible compliance
option will be particularly helpful to smaller generating units that are co-located with larger generating
units, but may not be economic to retrofit with pollution control systems.

Response to Comments 11 -12: The agency appreciates these commenters' support of emissions
averaging.

3. Request expanded flexibility for emissions averaging.

Comment 13: Multiple commenters (17718, 17816, 17820, 18037, 18539, 19114) state that the
proposed emission rate averaging plan does not provide much flexibility because the emission rate limits
are so low. According to the commenters, in order for a source to take advantage of these provisions, at
least one unit would need to achieve a rate substantially lower than the MACT limit, and there is no
evidence that such rates are achievable for any existing units. The commenters state that the mass-based
approach would provide each facility with a total annual mass emission limit for HC1, PM, and Hg that
could provide flexibility for the source to operate in the most economical way to meet that facility-wide
limit.

Comment 14: Numerous commenters (17627, 17718, 17719, 17737, 17740, 17768, 17774, 17775,
17813, 17816, 17820, 17856, 17885, 17902, 17913, 17928, 18024, 18037, 18539, 19114) state that the
averaging provisions should not be limited to units at a facility but should be expanded to include
adjacent units that have controlled access within a common fence line. The commenter states that the
EPA can provide additional flexibility and cost savings on emission reductions by revising the facility
definition to include units within a common fence line. Commenter 19114 suggests that a unit could
have the annual mass limit set as a multiple of the design heat input, the HAP limit for each constituent,
and the average capacity factor for the unit for the previous 3 years. Commenter 17740 suggests that
emissions averaging for units in different subcategories could easily be accomplished by requiring the
units to develop an emissions averaging plan, similar to the plan required for NOx emissions averaging
under the Acid Rain Program at 40 CFR 76.11. According to the commenter, such an approach could
easily be used in the EGU MACT rule to allow units in different subcategories to meet
the HAP emission standards through emissions averaging. Commenter 17928 further states that oil-
based units are particularly disadvantaged by the proposed constraints on averaging because they are
often stand-alone units that would not be able to average emissions with other units at a facility.
According to the commenter, oil and coal units at a facility should be permitted to average emissions.

Response to Comments 13 -14: The agency reviewed the commenters' suggestions, and the rule
continues to allow emissions averaging of a rate, not mass, from existing units within the same

347


-------
subcategory. EGUs in the same subcategory located at one or more contiguous properties, belonging to a
single major industrial grouping, which are under common control of the same person (or persons under
common control), remain eligible under to rule to engage in emissions averaging. Should a commenter
find these requirements problematic, he or she may use another of the compliance demonstration
approaches contained in the rule.

Comment 15: Commenter 17627 requests that regulated entities should be allowed to bubble emissions
from EGUs within a 50 kilometer (km) radius to determine source deposition mercury "hot spots"
in Technical Support Document: National-Scale Mercury Risk Assessment Supporting the Appropriate
and Necessary Finding for Coal and Oil-Fir ed Electric Generating Units (p. 6). According to the
commenter, allowing EGUs to average emissions from regional sources will still reduce the deposition
from sources the EPA links to the Hg "hot spots" while also providing additional compliance flexibility
for sources that have a limited number of EGUs.

Response to Comment 15: The agency has considered the commenter's suggestion, but, apart from the
contiguous property eligibility criterion mentioned in the rule, emissions averaging from EGUs within a
specific area, but not on properties adjacent to each other, will not be allowed.

Comment 16: Commenters (17623, 17655, 17705) indicate that the emission averaging criteria are too
rigid. Commenters (17623, 17655, 17757, 17758) request broader applicability and more flexibility in
emissions averaging. Commenters (17623, 17758) believe the limiting criteria for emissions averaging
provisions is too rigid to provide significant flexibility or cost reductions. Commenter 17623 notes the
inflexible structure is not needed because all facilities will collectively be subject to the same emissions
limit and all required reductions would occur. Commenter 17758 indicates that the EPA does not
provide details as to why it has determined that a broader approach would lessen the MACT floor, does
not enumerate any of the implementation or enforcement issues that could arise from allowing emission
averaging in any of the scenarios the rule bars, and this lack of information deprives commenters the
opportunity to assess, comment on, and address the EPA's concerns. Commenter 17758 went on to state
that the EPA does not explain why emission averaging provisions or limitations that were applied in
other MACT rules are applied in Utility MACT or what characteristics of those other sources are
comparable to Utility MACT sources (i.e., why are limits that were deemed necessary for synthetic
organic chemical manufacturing appropriately applied to electricity generation). In fact, commenter
17758 states that the EPA appears to assume that past rulemaking limits applied to emissions averaging
create an enforceable "criteria" that must be satisfied in this rule for utility generators. Commenter
17758 states that the EPA has not explained why any of the additional limiting criteria are needed if the
owner or operator can demonstrated that total averaged emissions do not exceed the limits that would be
applied to individual units. Commenter 17758 states the EPA has not demonstrated that limiting the use
of emissions averaging would obviate the unspecified implementation and enforcement issues that the
EPA suggests are of concern. Commenter 17758 further states the EPA fails to recognize the compliance
and enforcement difficulties that would be created by imposing the proposed limitations on averaging;
for example, it would be substantially more complicated and expensive to segregate, measure separately,
and monitor the emissions of units that share a common stack to determine that each is in continuous
compliance with the MACT standard for a particular pollutant than to allow these units to use averaging
by measuring common emissions from the stack.

Response to Comment 16: The agency has considered all but disagrees with most of the commenters'
assertions and notes that the commenters provide no data to support their assertions. We specifically
disagree that broader averaging is consistent with the statute as explained in the preamble to the HON
NESHAP:

348


-------
The fundamental problem with the broader averaging approach[, beyond sources in the same
category or subcategory,] is that it allows averaging among multiple sources. The HON has
defined the source, for the purposes of this standard, as the collection of SOGMI emission points
within a major source. Many major sources containing such points will also contain other points
not covered by this standard but to be covered by later, different MACT standards. Each of these
standards will have a separate floor, and the statute requires that each standard be no less
stringent than its floor. If averaging were allowed between sources covered by two separate
standards, it is likely that one of the sources involved in the average would be emitting HAP's at
a level that violates the standard applicable to it. Thus, averaging between multiple sources in
different categories is not legally defensible.

Similarly, allowing averaging between new and existing sources at the same facility would also
likely lead to one source failing to meet its applicable standard. There are separate MACT
standards with separate floors for new and existing sources within the HON, just as there will be
separate standards for sources in different categories at the same site. An average that included
sources with different floors and different standards cannot be reconciled with the statutory
requirement that each source in the category comply with the applicable standard.

59 FR 19427 (April 22, 1994)

Based on the long standing interpretation of the statute, the rule is unchanged. Further, we note that
commenters appear to presume that the agency must justify not allowing averaging on a broader level,
but such an assertion is not valid. CAA section 112 does not expressly authorize averaging and the final
rule would be consistent with the statute absent any allowance for averaging. The EPA's policy
concerning averaging is based in part on our interpretation of the statute and commenters have not
provided a viable alternative interpretation, nor have the commenters provided information that would
call into question our policy justifications for limiting averaging in the manner proposed. That certain
EGU owners or operators may not be able to avail themselves of the emissions averaging options (e.g.
because they vent units in different subcategories to a common stack) or may choose not to because they
determine that the potential benefits of averaging do not justify compliance with the requirements to
average does not render the provisions invalid.

Comment 17: Several commenters (17623, 17627, 17689, 17736, 18037) state that limiting emissions
averaging to only units in the same subcategory shrinks the universe of sources that can use this option.
Commenters 17655 and 17757 encourage the EPA to allow averaging between units at different
facilities that are under the same/common control and operating in the geographic region or at adjacent
facilities. Commenters 17655 and 17881 encourage the EPA to allow averaging new unit emissions with
existing unit emissions. Commenter 17623 states that not allowing new facilities to participate puts new
generation capacity at a disadvantage and reduces the effectiveness of the averaging program.
Commenter 17623 states that allowing emissions averaging for new facilities will incentivize installation
of state-of-the-art controls on new units. Commenter 17655 disagrees with the EPA's argument that
allowing new and existing averaging would be too cost effective and states this argument would not
stand up to a test of arbitrariness. Commenters 17758 and 18037 suggest the EPA allow emissions
averaging across all affected units (both coal and oil) on a facility basis, including both new and existing
units and where averaged units share a common stack. Commenter 17758 suggests the EPA allow
broader emissions averaging where it can be demonstrated that public health and environmental benefits
are preserved. Commenter 17881 states that averaging across multiple new EGUs would minimize the
risk of startup, shutdown or malfunction at a single unit resulting in an exceedance of an applicable
emission limit.

349


-------
Response to Comment 17: As mentioned earlier, the agency believes emissions averaging subject to
certain unit eligibility criteria, including existing units within the same subcategory using emissions
testing on contiguous properties under common control, in the rule can provide a cost-effective, flexible,
environmentally-friendly means of demonstrating compliance. Other suggestions, such as including new
units that can be designed for appropriate emissions control devices from the onset or mixing units from
differing subcategories with differing emissions limits, are not consistent with the statute as discussed
above and, in any case, we do not believe such averaging would be appropriate in any case. The rule has
not been revised for these suggestions. Note that the final rule contains work practice standards during
periods of startup or shutdown.

Comment 18: Commeterl7758 states that the EPA previously proposed emissions averaging for EGUs
in its 2004 proposed standards and the rationale for including this option remains valid.

Response to Comment 18: The agency thanks the commenter for his support.

Comment 19: Commenter 17705 believes EGUs should be allowed to average actual emissions data
from CEMS to determine monthly average weighted emissions for the units participating in an
averaging plan, as this simplifies the demonstration of compliance.

Comment 20: Commenter 17705 notes that section 63.10022 requires facilities using emissions
averaging to also comply with operating limits for control devices and fuel limitations for Hg and
chlorine on top of numeric stack emissions standards. Commenter 17705 states this burden can be
alleviated by allowing an averaging plan that based on CEMS usage, as CEMS data is a more accurate
indicator of continuing compliance with a numeric standard than operating limits set during periodic
performance tests or fuel analyses.

Comment 21: Commenter 17705 stated that the availability of the alternate SO2 standard coupled with
use of emissions averaging based on use of existing certified CEMS is likely to be a preferred
compliance option for sources with existing FGD technology and should be fully accommodated in the
final rule language.

Response to Comments 19-21: The agency supports the commenters' suggestions regarding use of
CEMS for units subject to emissions averaging, and the rule has been revised so that units that use
CEMS can participate in emissions averaging. Note that, as stated elsewhere, the rule no longer requires
fuel analyses for pollutants.

Comment 22: Commenter 17402 notes emission averaging is permitted under section 112 and there is
ample precedent for allowing it. Commenter 17402 notes the emissions averaging is permitted under
section 112(d) of the CAA(particularly given the important limitations included in the rule) and there is
ample precedent for allowing such facility-wide emissions averaging (cites 6 part 63 NESHAP rules
with emissions averaging). Commenter 17758 further indicates that the CAA provides flexibility in
allowing emissions averaging broadly and does not direct the agency to promulgate standards that are
applicable unit-by-unit or facility-by-facility; the CAA does not mandate that the EPA apply MACT
standards on an individual unit basis; CAA section 112(d)(1) provides that the EPA shall promulgate
regulations "for each category or subcategory of major sources and area sources of hazardous air
pollutants..." (emphasis added); and CAA section 112(d)(2) standards are applicable to "new or existing
sources" (emphasis added).

350


-------
Response to Comment 22: The agency acknowledges the commenters' support for emissions averaging
and for the agency's discretion in designing emissions averaging provisions according to program needs.
No changes to the rule regarding expansion of emissions averaging across subcategories or to new units
were made.

Comment 23: Commenters (17402, 17655) support weighting by heat input (based on the performance
test results). Commenter 17655 agrees that existing DAHS can perform these calculations and produce
reports.

Response to Comment 23: The agency thanks the commenters' for their support of weighting
emissions rates by heat input.

Comment 24: Commenter 17648 supported the four criteria required by the EPA to participate in
emissions averaging and went on to state that the EPA should also apply a discount factor to assure that
emissions from the affected sources as they are actually controlled will be at least as stringent as the
total sum of emissions that would be achieved if each unit at an affected source were controlled
individually to the level required by the rule, as it has done in prior NESHAP.

Response to Comment 24: The agency disagrees with the commenter's support for use of a discount
factor, for under the emissions averaging procedures contained in the rule, each group of units subject to
emissions averaging will have to meet the emissions limits of a specific subcategory. While these
emissions limits would otherwise apply on an individual basis, through emissions averaging, the group's
total emissions will be no greater than the sum of the emissions from individual units. Note that the
emissions from units that engage in averaging under this rule are not bound by a cap, but by the
otherwise applicable emissions limit. The rule does not include a discount factor.

Comment 25: Commenter 17774 states that disallowing the new facilities from emission averaging puts
new generation capacity at a disadvantage and reduces the effectiveness of the program. According to
the commenter, units subject to the NSPS would have to continue to comply with the individual PM
limits in that rule even if the emissions averaging option is used, further reducing the utility of the
option.

Response to Comment 25: The agency disagrees with the commenter, and the rule continues to exclude
new units from emissions averaging. As mentioned in the preamble to the HON rule (see 59 FR 19425),
the agency does not believe the statute authorizes emissions averaging for new affected sources. In
addition, it is most cost effective to integrate state-of-the-art controls into equipment design and to
install the technology during construction of new sources so, even if we concluded that such averaging
was authorized, we would decline to allow averaging of new sources. One reason we allow emissions
averaging is to give existing sources flexibility to achieve compliance at diverse points with varying
degrees of add-on control already in place in the most cost-effective and technically reasonable fashion.
This flexibility is not needed for new affected sources because they can be designed and constructed
with compliance in mind.

Comment 26: Commenter 17798 recommends initial emission averaging by utility ownership and state
staged to facility averaging 2 years later. The commenter states that the EPA provides a mechanism in
the NESHAP rule for the agency to approve a 1-year compliance extension on an EGU sector-wide
basis.

351


-------
Response to Comment 26: The agency considered the commenter's recommendation, but did not
change the rule to allow phase-in of emissions averaging. An EGU owner or operator will need to have
his or her emissions averaging plan developed and results of all testing in hand on or before 180 days
after the unit's first compliance date in the rule.

Comment 27: Commenter 17881 states that in section 63.10006(o) if emission limits are consistently
being met, then reduced frequency of testing should be allowed for the units utilizing emissions
averaging.

Response to Comment 27: The agency disagrees with the commenter, and the rule continues to exclude
those units associated with emissions averaging from reduced emissions testing frequency.

Comment 28: Commenter 9738 states that the inclusion of an alternative compliance provision within
the proposed rule that would allow owners and operators of existing affected sources to average the
emissions by sources within the same category allows more flexibility for owners. According to the
commenter, this may increase the feasibility of the compliance deadlines in two ways: First, if cost is a
concern, owners and operators may be able to strategically implement technology to bring their plant
into compliance on only some of the smokestacks. The commenter states that while this could ultimately
balance the total emissions of the plant, it would require the owners and operators to raise fewer funds,
which should thus decrease the amount of time needed to prepare fiscally for the new standards. The
commenter states that second, if an owner or operator chose to selectively implement such technology,
less work would need to be performed, as only a portion of the smokestacks would require retrofitting.
Thus, according to the commenter, this should also require less time to bring the facility into
compliance, and this alternative provision allows for companies to strategically stagger their compliance
efforts and increases flexibility. The commenter states that further, for facilities which have already
implemented some such technology, this alternative provision may eliminate the need for additional
action. According to the commenter, this would achieve the goals of the proposed bill by promoting the
same reductions in emissions, thus having the same societal impact overall.

Response to Comment 28: The agency appreciates the commenter's support of emissions averaging
within a subcategory.

4. Clarifications and modifications to emissions averaging.

Comment 29: Commenter 17402 suggests clarifications to improve emissions averaging for
compliance. Commenter 17402 notes that section 63.10009(f)(3) and section 63.10022(a)(1) are
somewhat contradictory and could be interpreted as requiring compliance in the first month of collecting
data. Several commenters (17725, 17402, 17775, 17881) recommend clarifying in section
63.10009(f)(3) that the first compliance period begins after 12 months of data have been accumulated,
and in section 63.10022(a)(1) that compliance is demonstrated each month, and that compliance is first
determined after 12 months of data are collected. Commenter 17775 states that requiring compliance
with both a monthly average and a 12-month rolling average of those values makes no sense.

Comment 30: Several commenters (17821, 17856, 17902) recommend that the EPA allow sources to
demonstrate compliance with an averaging plan over a 12-month period and not on 30-day rolling
average basis. Commenter 17821 further states that the primary reason for this is that the EGUs require
periodic outages for scheduled and unscheduled maintenance. According to the commenter, when a unit
is in an outage, the remaining units could be forced to shut down during the same period if compliance
with an averaging plan must be demonstrated based on only one month's data. The commenter states

352


-------
that if however compliance with an averaging plan were based on the average of 12 consecutive months,
a facility would be in a better position to absorb the effects of individual unit outages over the course of
a year. Commenter 17856 further states that revising the rule as suggested would provide needed
flexibility to the regulated community, eliminate compliance and enforcement uncertainties, and achieve
the same emissions reductions that the EPA seeks.

Response to Comments 29 - 30: The agency has reviewed the commenters' suggestions, and the rule
has been revised so that the results of the emissions testing are used for each 30 boiler operating day
rolling average during the quarter in which the emissions testing is conducted.

Comment 31: Several commenters (17402, 17775, 17881) recommend operating parameters be
removed from the averaging plan required under section 63.10022(a)(2) to (5). Commenters further state
that if the operating parameters are required, the averaging period for control devices should be extended
from a 3-hour average to a 30-day rolling day average period to account for variable
conditions. Commenters recommend that in calculating the ESP power operating parameter, the
calculation should use the lowest (or highest) value obtained during the performance test as opposed to
the average low (or high) values of the performance testing. Commenter 17881 further states that the
references in section 63.10022(a)(2) through (a)(7) to the "3 hour average parameters" established
during the performance test does not clearly line up with the requirements of Table 4 or Table 8 and is
confusing.

Response to Comment 31: The commenters' suggestions are moot, for the rule no longer requires
monitoring of control device operating parameters.

Comment 32: Commenter 17174 states the EPA should clarify the deadline to established emission
caps to demonstrate compliance with the emissions averaging option for the emission level or control
technology. The commenter notes that section 63.10009(c) and section 63.10009(g)(2)(i) appear to have
a contradiction in dates (30 days vs. 60 days), and the EPA should correct this in the final rule.

Response to Comment 32: The agency considered the commenter's suggestion, and the rule now has a
consistent date (on 180 days after [INSERT DATE 3 YEARS AFTER PUBLICATION OF THIS
FINAL RULE IN THE FEDERAL REGISTER!, or the date on which emissions testing done to support
your emissions averaging plan is complete (if the Administrator does not require submission and
approval of your emissions averaging plan), or the date that you begin emissions averaging, whichever
is earlier).

Comment 33: Commenters 17648 and 17881 request clarification of emissions averaging provisions,
with assertions that the preamble indicates emission averaging provisions do not apply to units that share
a common stack with units in a different subcategory, while the rule text in section 63.10009(h)-(k) is
confusing, and arguably may allow sources with units in different subcategories emitting through the
same stack to average emissions to demonstrate compliance, without clarifying that all of the other
relevant averaging provisions, such as the emissions cap, apply.

Response to Comment 33: The agency considered the commenters' suggestions but the rule is
unchanged. What the rule prohibits is units from differing subcategories being included in emissions
averaging, not only units from differing subcategories sharing common stacks. The rule provisions cited
describe how EGUs sharing common stacks can determine compliance with an emissions averaging
program.

353


-------
Comment 34: Several commenters (17705, 17718, 17737) state the EPA should clarify in sections
63.10009(e)(1) (initial compliance, includes S02) and 63.10009(f)(1) (continuing compliance, no
mention of SO2) that the SO2 surrogate limit as an alternative standard for acid gases can be used under
the emissions averaging compliance option.

Response to Comment 34: The agency agrees with the commenters' suggestions, and the rule has been
revised to include SO2 as eligible for emissions averaging.

Comment 35: Commenters 17623 and 17775 suggest the EPA include more flexibility in the
submission timing of the emissions averaging plan, and notes that submittal 180 days prior to
compliance is a lengthy lead time that limits the effectiveness of the EPA program because facilities
may not have yet finished control technology installation to formulate the emissions averaging plan.

Response to Comment 35: The agency considered the commenters' request, and the rule has been
revised so that an emissions averaging plan must be developed by 3 years after the rule has been
promulgated. In addition, results from all initial emissions testing must be received and ready for use in
compliance calculations by 3 years after the rule has been promulgated.

Comment 36: Several commenters (17655, 17718, 17795, 18429) agree that 30-day block averaging
should supplant rolling averages in a unit averaging plan, as there are inconsistencies that would accrue
from varied operating schedules of the affected units. Commenter 17795 further states that lengthening
the averaging period would help achieve the flexibility the EPA intended by granting facility averaging.
Commenter 18429 recommends that emissions averaging should be based on annual mass emissions
rather than on a rate basis, and should be allowed between any groups of sources that contractually
commit to an emissions averaging program similar to the original NOx compliance program under the
Acid Rain Program.

Comment 37: Several commenters (17718, 17775, 17795, 17800, 18031) state that the EPA must
clarify ambiguities in the proposed rule and explain exactly how the provisions must be implemented.
According to the commenters, it is unclear how to account for units which are shut down for an outage
or whether individual unit baseline testing is necessary. Commenter 17775 suggests that in the event of a
unit outage, the EPA should allow use of at least a 3-month average. Commenter 17795 further states
that if one unit operates slightly above the limits could not operate during the first year of compliance,
and the unit used to average it into compliance was in outage, this would negate any benefit or flexibility
the EPA intended by incorporating the averaging provision into the proposed rule. Commenter 17800
recommends that the EPA adopt the averaging time of a 12-month rolling average that the State of
Illinois has determined to be appropriate in their Mercury Rule. According to the commenter,
lengthening of the averaging time would help to account for normal process variations and account for
emissions during normal startup, shutdown and malfunction events.

Response to Comments 36 and 37: The agency reviewed the commenters' suggestions, and the rule
now allows a 90-boiler operating day rolling average period for mercury emissions from EGUs in the
EGUs designed for coal > 8,300 Btu/lb subcategory that are included in an emissions averaging group,
along with the existing 30-boiler operating day rolling average periods for other pollutants in other
subcategories. Should these requirements prove too difficult for an EGU owner or operator, he or she
should choose another compliance demonstration option. Note that the final rule includes work practice
standards during periods of startup or shutdown, so the request to lengthen the averaging time to account
for such periods is moot.

354


-------
Comment 38: Several commenters (17718, 17737, 17775, 17821, 18031) state that all of the equations
(Eq. 1, 2, 3 and 4) seem to specify that the emission rates to be used are "determined during the most
recent performance test". According to the commenters, the EPA should clarify that if CEMS (i.e.,
PM, HC1 or Hg) are being used to determine compliance with the limits, values from those monitors
could be used. Commenter 17775 recommends that the EPA should revise 40 CFR 63.10009 to include
procedures for CEMS, and make clear that units using CEMS to calculate average weighted emissions
do not have to comply with the operating limits for control devices in proposed 40 CFR 63.10022.

Comment 39: Commenter 17718 states that if SO2 data via CEMS is being gathered for comparison
with the acid gas alternate SO2 limit, those values should be allowed for use as on a monthly
demonstration method for HC1.

Response to Comments 38 and 39: As mentioned elsewhere, the agency agrees that units using CEMS,
including SO2 CEMS, are eligible to participate in emissions averaging, and the rule now clarifies how
EGUs using CEMS in emissions averaging are to determine compliance. Those units would use the
emissions rate determined from the 30 (or 90) boiler operating day period ending at the end of each
month s at the end of each calendar month in their calculations. Note that as mentioned elsewhere,
operating limits are no longer required for units using CEMS.

Comment 40: Commenter 17718 recommends that in determining an emission limit from different
subcategories that emit from a common stack (40 CFR 63.10009(j)), it would be more appropriate to use
the maximum rated heat input (or capacity) for the combined units to allow more flexibility in
determining the common stack emission limit.

Response to Comment 40: The agency disagrees with the commenter's suggestion that the rule's
emission averaging provisions need more flexibility, and the rule has not been changed.

Comment 41: Commenter 17718 requests the EPA to clarify whether a "pre-test" be conducted so that a
comparison can be made between a "30 day after" value and the initial compliance test. The commenter
states that the EPA should specify the notification and submittal requirements for such a test and that the
EPA should clarify what kind of documentation is needed for the "control technology" option to prove
that it has not become "less effective."

Comment 42: Commenter 17881 states that the provisions of section 63.10009(c), require that "the
HAP emission rates observed during the initial compliance test must not exceed those being achieved on
the date which is 30 days following rule finalization or that the control technology employed during the
initial compliance test should not be less effective for the HAP being averaged than the control
technology employed on the aforementioned date." According to the commenter, the existing units have
no inherent requirement to conduct testing or control device removal efficiency evaluations prior to the
compliance date, which is 3 years following rule finalization.

Response to Comments 41 - 42: The agency considered the commenters' suggestions, and as
mentioned elsewhere, the rule now clarifies that an EGU subject to emissions averaging must have its
emissions results available for use in calculations on or before 3 years, not 30 days, after rule
promulgation. Moreover, the rule now clarifies that an EGU owner or operator needs to ensure that the
"design efficiency of the emissions control technology has not changed", as opposed to ensuring that the
"control technology" has not become "less effective," but does not specify the kind of documentation an
EGU owner or operator would be required to provide.

355


-------
Comment 43: Commenter 17718 states that the EPA should clarify why the presence of an ESP would
require monthly fuel content determinations.

Response to Comment 43: The comment is moot, as the rule no longer requires fuel analysis for
pollutants.

Comment 44: Commenter 17725 requests revision to the compliance timeframe and the addition of a
definition of an oil-fired facility. The commenter states that clarification is needed for dual fuel units to
average emissions of oil only units. According to the commenter, the use of interruptible natural gas can
offset oil-fired emissions, but the availability of natural gas is often restricted, especially in the winter
months and during the summer high demand period, and without a supply of gas in all months, a facility
will not be able to use emissions averaging for compliance because it may not meet the proposed limits
for the initial 12-month period on a month-by-month basis.

Comment 45: Commenter 17725 requests that the use of liquid fuel should not count towards the site
averaging compliance demonstration when the gas supply to the EGUs is unavailable due to factors
outside of the facility's control or when the EGU must use oil rather than gas to comply with
environmental or market based testing requirements.

Response to Comments 44 - 45: The agency reviewed the commenter's suggestions, but no changes to
the rule were made. The rule already defines an oil-fired electric utility steam generating unit, and the
rule maintains the eligibility criterion of having only those EGUs in the same subcategory as available
for inclusion in emissions averaging. Should the commenter find that his EGUs would be unable to meet
all emissions averaging criteria, he or she should use another option to demonstrate compliance.

Comment 46: Commenter 17730 states that the emissions averaging plan is an unnecessary element of
the proposed rule and should be eliminated from the final rule.

Response to Comment 46: The agency disagrees with the commenter's assertion, and the requirement
to develop an emissions averaging plan remains in the rule. The agency finds such a plan helps the
owners and operators understand what is to be done, which units are to be included, and how
compliance is to be determined, as well as helping regulatory agencies understand a site and its
emissions averaging program. Note that the rule also requires plan submission and, in some instances,
plan approval should the Administrator or a delegated authority request one or both of those activities.

Comment 47: Commenter 17736 states that the emissions averaging provisions do not provide
operational flexibility due to the short 30-day compliance period.

Response to Comment 47: As mentioned elsewhere, the agency and other commenters believe the
rule's emissions averaging provisions offer much flexibility. Moreover, as discussed in the preamble, the
rule now allows EGUs designed for coal > 8,300 Btu/lb subcategory that are included in an emissions
averaging group for Hg emissions a 90-boiler operating day rolling average period. Should an EGU
owner or operator disagree, he or she should choose another compliance demonstration method.

Comment 48: Commenter 17775 opposes the requirement for the source to document the type, design,
and operating specifications of the control devices installed on the effective date of the rule if
performance test results are not available.

356


-------
Response to Comment 48: The agency reviewed the commenter's suggestion, and, apart from
identifying the control technology from each EGU, the rule does not require other information regarding
the control devices.

Comment 49: Commenter 17821 states that section 63.10009(g)(2)(i) requests from all units in a
potential averaging group, that sources identify the applicable emission level or control technology that
is in place 60 days after the publication of the final rule. According to the commenter, that would require
stack testing and other forms of monitoring, which a number of sources would not have performed by
the date of the final rule. The commenter states that this suggests that some sources will have to replace
existing control technologies with different technologies.

Response to Comment 49: The agency reviewed the commenter's suggestion, and, as mentioned
elsewhere, the rule now requires information, including applicable emissions level or control technology
as well as emissions test results, to be available within 3 years after promulgation.

Comment 50: Commenter 17881 states that it is not clear about how to apply emission averaging for
CEMS versus stack testing results; i.e, how to compare a 30-day average from a CEMS to monthly stack
test results.

Response to Comment 50: The agency agrees with the commenter, and the rule now describes how 30-
day average CEMS values will be used with quarterly stack testing data to demonstrate compliance.

Comment 51: Commenter 17821 states that it is the EPA's intention to prevent units from using a
lower, less restrictive emissions value in an averaging program based on the initial performance test than
a unit was able to achieve when the final rule becomes effective. According to the commenter, from a
practical point, this provision is flawed and unenforceable for two reasons:

a.	The EPA has specified no practical way to determine what level of HAP emissions each unit is
achieving on the date of the final rule without having a battery of performance tests on each affected unit
and/or a program of extensive monitoring.

b.	Many units will be undergoing control retrofits, such as the installation of FGD systems, sorbent
injection, ACI, and fabric filters that will change the configuration of a unit. Some projects on their own
could cause an increase in a unit's emissions, such as the potential for additional particulate related

to ACI.

Response to Comment 51: As mentioned elsewhere, the rule now requires information from emissions
testing be received and available for use in emissions averaging calculations on or before 3 years after
promulgation. As the emissions averaging compliance approach may require additional testing or
retrofits, an EGU owner or operator will need to include such factors in deciding whether or not to use
emissions averaging as a means of demonstrating compliance.

Comment 52: Commenter 17881 states that the EGUs located at a single stationary source may not
always have identical owners and/or operators contrary to section 63.10009(a). The commenter states
that the language at 63.10009(a) would not preclude emission averaging amongst units under partial
owners and/or operators, but perhaps the EPA should clarify this concept in the final rule preamble so as
to eliminate any possible confusion in the future.

357


-------
Response to Comment 52: The rule remains unchanged; EGUs under common control that otherwise
meet the eligibility criteria, as described elsewhere, could be included in an emissions averaging group.

Comment 53: Commenter 17881 states that it is not clear if these provisions apply to each individual
unit included in the averaging plan or all units in aggregate and notes that if multiple pollutants are being
averaged, it is possible that new control devices targeting a given pollutant (i.e., acid gases) could result
in a decrease in the control efficiency of another pollutant (i.e., PM or metals) and that control of a
specific HAP could necessitate a reduction in the control efficiency for a different HAP.

Response to Comment 53: The agency believes EGU owners or operators are in the best position to
weigh considerations mentioned by the commenter when deciding which compliance option to use. No
change has been made to rule language regarding this comment.

Comment 54: Commenter 17881 states that the calculations at 63.10009(e)(1) and (2) should be
dropped in their entirety as there is a major flaw in the initial qualification calculations, specifically,
equations 1 and 2 require that the maximum rated hourly heat input (i.e., MMBtu/hr) or steam output
(i.e., pounds) for each unit is to be used in the calculations. The commenter states that as long as the
HAP emission rate for at least one of the EGUs to be included in the averaging plan is less than the
applicable HAP limit, it is theoretically possible for the average HAP emission rate for the group of
units to be compliant, but that if the EPA persists in maintaining some form of these calculations, the
heat input or steam output used in the calculations should represent the projected monthly or annual heat
input which will be achieved under the averaging plan. According to the commenter, this would allow
those EGUs which will rely on capacity factor as part of the averaging plan to account for such reduced
utilization in the calculations.

Response to Comment 54: The agency disagrees with the commenter's concern, and the rule has not
been changed. An EGU owner or operator will have at least 3 years to get initial emissions testing
complete and should be able during that time to have each of the EGUs fully operable for the time
necessary to conduct emissions testing. If an EGU is unavailable, an EGU owner or operator could
exclude that unit from the emissions averaging group or choose another method of demonstrating
compliance.

Comment 55: Commenter 17881 states that the term "heat capacity" is improper in context of section
63.10009(f)(1) and (2), as heat capacity generally refers to the amount of heat required to change a
substance's temperature by a specified amount; the term "heat capacity" should be replaced with "heat
input". The commenter states that for Equation 3, the term Hb is currently specified as "The average
heat input for each calendar month of EGU, in units of MMBtu"; the units of MMBtu represent the total
monthly heat input, not the average monthly heat input (which would generally be expressed as
MMBtu/hr); and thus, the term "average" in the definition for Hb should be replaced with "total."

Response to Comment 55: The agency agrees with the commenter that the equations 1 and 2 should
refer to heat input, while equation 3 should refer to total monthly heat input, and the rule has been
revised with these clarifications.

Comment 56: Commenter 17881 states that in section 63.10009(e) and (f), the equations 1 through 5
must be revised or clarified. The commenter states that all emission rates are expressed in units of
lb/MMBtu or lb/TBtu, which ignores the fact that compliance on a lb/MWh or lb/GWh basis is also an
option per Table 2 of the proposed rule. According to the commenter, if the EPA intends to allow the
use of emission averaging to demonstrate compliance with pound per unit of electrical output limits, it

358


-------
may be appropriate to include additional equations which use electrical output as opposed to heat input
or steam output for weighting purposes.

Response to Comment 56: The agency agrees with the commenter that an emissions rate based on
electrical output, as well as on heat input, is appropriate for emissions averaging, and the rule has been
revised to include rates based on electrical output.

Comment 57: Commenter 17881 states that the paragraph (g)(2)(vii) is confusing, which states that the
averaging plan must include a demonstration that compliance with each of the applicable emission limits
will be achieved. Commenter is confused about what emission rates should be used to make this
demonstration.

Response to Comment 57: The rule's emissions averaging plan is intended to describe how each EGU
emissions averaging group meets its emissions limit. One way of accomplishing this is to provide the
results of each emissions test, along with requisite heat input information and the equations and results
of the equations, in the emissions averaging plan.

Comment 58: Commenter 17881 states that section 63.10009(h) does not include SO2 in the list of
those pollutants which may be averaged for common stacks. The commenter states that if this is just an
error, then the EPA should correct prior to rule finalization.

Response to Comment 58: As mentioned earlier, the rule has been revised to include S02 in the list of
those pollutants which could be used in emissions averaging.

Comment 59: Commenter 17881 states that the section 63.10009(i) stipulates that individual units
sharing a common stack must vent through a common emissions control system. Commenter
recommends that if EGUs associated with the common stack are all affected units within the same
category, compliance should be allowed at the common stack based upon treating such averaging group
as a single stack.

Comment 60: Commenter 17881 states that equation 6 of 63.10009(j)(l) is supposed to be used to
determine the common stack emission limit in cases where it is shared by EGUs in different
subcategories. According to the commenter, the current equation is lacking in several regards, and in
cases where the common stack emission levels can comply with the most stringent of the applicable
emission limits, this would negate the need to calculate custom common stack emission limits based
upon prorating the emission limits for applicable subcategories.

Response to Comments 59-60: The agency agrees with the commenter's first suggestion, and the rule
has been revised to treat emissions from a common stack used by only EGUs eligible for emissions
averaging as a single unit. The agency disagrees with the commenter's second assertion, and the rule has
not been changed. Existing EGUs from the same subcategory can share a common stack and be included
in emissions averaging provided that EGUs not in the emissions averaging group (perhaps because they
are new or they belong to a different subcategory) can be turned off during emissions testing of the units
within the emissions averaging group or that every EGU meets the most stringent emissions limit
applicable to any EGU. Should an EGU owner or operator find these eligibility criteria burdensome, he
or she should choose another compliance demonstration option.

359


-------
Comment 61: Commenter 17881 requests that the heat input/steam output records as required by
section 63.10032(e) should be kept on a monthly instead of daily basis, as all related calculations in
63.10009 are on a monthly rather than daily basis.

Response to Comment 61: The agency disagrees with the commenter's suggestion because the rule
contains a 30 boiler operating day rolling average, meaning that heat input is required on a daily, not
monthly, basis.

Comment 62: Commenter 17913 states that the emissions averaging demonstration should only be
based on an averaging period consistent with the given emission standard. According to the commenter,
for example, if emissions averaging is used to demonstrate compliance with a 30-day emission standard,
then the compliance demonstration should only be based on each 30-day compliance period. There is no
need or benefit to requiring instantaneous compliance with the standard during an initial performance
test, as currently required by the proposed regulation. The commenter states that the requirement to
demonstrate instantaneous compliance with a 30-day limit through emissions averaging
using performance test data eliminates much of the benefits of allowing for an emissions averaging
approach and doesn't provide benefits for facilities that wish to limit use of less-controlled units.

Response to Comment 62: The agency agrees with the commenter's suggestion to clarify how
compliance is demonstrated. As rule contains a quarterly compliance assessment based on results of
quarterly emissions tests for EGUs that use emissions testing and of 30 (or 90, as discussed elsewhere)
boiler operating day rolling averages for EGUs that use CEMS (or sorbent trap monitoring for Hg
emissions), the rule has been revised to stress compliance with the 30 (or 90, as discussed elsewhere)
boiler operating day rolling averages for those EGUs that rely on CEMS (or sorbent trap monitoring
systems for Hg emissions). Note that this means the quarterly emissions testing value is used during the
quarter to assess compliance with emissions limits. Should an EGU owner or operator find such an
approach problematic, he or she should choose another compliance demonstration option.

Comment 63: Commenter 19120 requests revision of the rule to allow for PM CEMS emissions data to
be used in emissions averaging to show compliance with metal HAP emissions. The commenter states
that this request could be completed through a site-specific alternative monitoring request per 40 CFR
63.8(f), but due to the potentially large number of facilities requesting a site specific approval to use
alternative monitoring and emissions averaging plans, the EPA should include this option directly in the
final rule. The commenter states that because approval from the EPA is required before a source may
use the alternative monitoring procedure, this could hinder the ability for sources to plan in advance and
be proactive with installation of compliance monitoring equipment.

Response to Comment 63: As mentioned elsewhere, the rule now allows EGUs that use CEMS,
including PM CEMS, to be eligible for emissions averaging. Note that data from a PM CEMS would be
used to show compliance with the filterable PM, not non-Hg HAP metals, emissions limit.

5. Opposition to discount factor.

Comment 64: Numerous commenters (17714, 17718, 17402, 17623, 17689, 17705, 17716, 17725,
17730, 17731, 17737, 17774, 17775, 17816, 17820, 17821, 17885, 17904, 18014,18025, 18449, 18498,
18023) disagree with use of a discount factor. According to the commenters, imposition of a discount
factor effectively lowers the allowable emissions for those sources without any justification. The
commenters note that the EPA has used discount factors in other NESHAP where the agency believed
there was variation in the types of units engaged in averaging. The commenters states that

360


-------
the EGUs covered by this rule are fairly homogeneous, and the current proposal does not allow
averaging between units of different subcategories. Commenter 17904 states that a discount factor will
simply act as a deterrent to emissions averaging.

Comment 65: Commenters 17402 and 17716 notes the discount factor increases the stringency of the
emissions standards (amounts to an "above the floor" standard) for sources participating in emissions
averaging. Commenter 18023 stated that tightening the standards by any percentage for sources that
emissions average makes an impossible compliance situation even worse. Commenter 17402 notes that
the discount factor is not being applied in the Utility MACT to account for variation in types of units, as
was the case where discount factors have been applied for other NESHAP. Commenters 17402 and
17623 agree with the EPA that the "homogeneous" nature of the sources eligible for the Utility MACT
averaging provision makes a discount factor unnecessary. Commenters 17402 and 17623 agree that
requirements to monitor and demonstrate compliance assure environmental benefits are achieved and
also make the discount factor not appropriate. Commenter 17705 concurs that emissions averaging
for EGUs that are co-located at a single facility should be straight-forward. Commenter 17705 indicates
that the NESHAP numeric limits and the additional requirements for control device operating
parameters and fuel limits already reduce the usefulness of emissions averaging as a compliance option,
and if the EPA further adds a discount factor, the commenter suspects emission averaging will not be a
viable compliance alternative for any sources.

Comment 66: Commenter 17648 states that using a discount factor would be more consistent with the
HON Rule. Commenter 17648 notes that the HON Rule was clear that the cost savings for sources
choosing emissions averaging should be considered in determining the appropriateness of a discount
factor. 59 FR 19430. The commenter states that more recently, the EPA relied upon its reasoning in the
HON Rule to apply the 10 percent discount in the emissions averaging provisions for ICI Boilers (see 76
FR 15619; 75 FR 32035), and that its decisions in the HON and ICI Boiler NESHAP were well founded
and necessary to assure that sources opting to use emissions averaging were emitting at levels no less
stringent than would be required under a unit-by-unit MACT standard. The commenter states that the
EPA offers no rational basis for failing to adopt the same approach in this rule.

Comment 67: Commenter 17714 states that allowing averaging without discounting would provide a
positive incentive to encourage companies to upgrade or install controls that would achieve reductions
beyond compliance requirements and allow the utilities to achieve more cost-effective reductions overall
by investing resources where the greatest reductions can be made.

Comment 68: Commenter 17768 states that applying a discount factor would essentially penalize
averaging and disincentivize sources from using this option and that is also possible that averaging may
lead to fewer reductions in emissions and thus fewer benefits to the general public.

Comment 69: Commenter 17928 states that averaging provides valuable flexibility but is already
constrained by the differing schedules of plant outages at the same facility, as well as emissions
variability. The commenter states that a ten percent penalty further limits the utility of this option.

Response to Comments 64-69: The agency reviewed the commenter's concerns and suggestions, but
decided not to change the rule by including a discount factor for those EGU owners or operators who
choose to use emissions averaging. The agency agrees with many of the commenters who pointed out
EGU homogeneity as being a reason why emissions averaging without a discount factor is well-suited
for this rule. Requirements for units subject to the HON rule, which covers a broad number of unit types,
products, and processes need not be forced upon EGUs which differ generally only in the fuel used to

361


-------
produce electricity. The agency believes that difference is accounted for in this rule by prohibiting units
from differing subcategories - which are fuel based - from participating in emissions averaging. The
agency believes the EGU owner or operator flexibility coupled with the lower cost advantage of
emissions averaging makes such a program a viable choice, particularly for little used or soon-to-be
retired EGUs. Should an EGU owner or operator disagree, he or she should choose from among the
other compliance demonstration options.

6. Support of discount factor.

Comment 70: Commenter 17648 supports the four criteria required by the EPA to participate in
emissions averaging and states that the EPA should go further and also apply a discount factor, as it has
done in prior NESHAP. Commenter 17648 states the proposed emissions averaging provisions do not
sufficiently recognize and compensate for the fact that averaging may not assure that all units are being
controlled aggregately to a degree no less stringent than they would need to be controlled if they were
controlled individually. In failing to incorporate a discount factor, Commenter 17648 states the EPA
may unfairly advantage multiple-unit sources over single-unit EGUs. Commenter 17648 notes that
having accounted for variability in setting emission limitations by calculating MACT floors based upon
the 99% UPL, the EPA has provided sources with ample protection from anomalous
outcomes. According to the commenter, the 99% confidence level was established to account for
variability, measuring the variability of single-unit, single measurements from the average, but under the
EPA's averaging provision, a multiple-unit facility will reduce variability by averaging both between
units and over time. According to the commenter, the 99th UPL for facilities that average would be
closer to the actual average of the top 12% than the 99th UPL for an individual measurement at an
individual facility, and thus, sources with multiple units eligible for averaging may be able to take
advantage of averaging to avoid installing or operating controls that would be required for individual
sources. The commenter states that incorporating a discount factor is important to maintain a level
playing field, to ensure that sources will in fact install controls that reduce emissions while providing
flexibility to do so in the most cost-effective manner possible and that it is also the only way to ensure
that the limit actually equals the average attained by the average of the best performing 12% of the
sources within the subcategory.

Comment 71: Commenter 17648 disagrees with the EPAs suggestion that homogeneity of sources
makes a discount factor unnecessary, and notes that the substantial subcategorization into 11 different
subcategories in the ICI Boiler NESHAP undercuts the EPA's rationale for not proposing a discount
factor in the Toxics Rule. In the ICI Boiler NESHAP, commenter 17648 states that the subcategorization
reduced variation among sources within the subcategory, and that NESHAP nonetheless retained a
discount factor. 76 FR 15612. Commenter 17648 states that the EPA's rationale also fails to account for
the mathematical/statistical basis for requiring a lower limitation when averaging is allowed. According
to the commenter, by basing the initial limit on the 99% UPL rather than the more conventional 95
percent UPL in both rules, the EPA has already accounted for any greater variability within the pertinent
subcategories. Commenter 17648 states that if there is less variability within the EGU subcategories, this
would only suggest that the EPA should employ a somewhat smaller discount, and would not support
eliminating the discount altogether.

Comment 72: Commenter 17648 supports the emissions cap for any individual regulated unit operating
above the emissions limitations that would apply to that unit at the level achieved 30 days after
promulgation of the Toxics Rule, however, this cap alone will not achieve sufficient assurance that
emissions averaging will be at least as stringent as the conventional MACT.

362


-------
Comment 73: Commenters 17648 and 17789 state that prior NESHAP have relied on additional
safeguards such as the cap only as a supplement to the 10 percent discount and urge the EPA to continue
to use the criteria to limit averaging.

Comment 74: Commenter 17718 states that imposition of a discount factor effectively lowers the
allowable emissions. According to the commenter, a discount factor is unnecessary because the
proposed rule incorporates a number of other safety factors that obviate the need for a discount factor.

Comment 75: Several commenters (19536, 19537, 19538) states that the EPA should add a discount
factor requiring lower emissions from plants which comply by averaging the emissions of multiple units.
According to the commenter, the agency's variability analysis is based on emissions from three test runs
from a single boiler, operating over a 2 (Hg and PM) or 3 (acid gases) hour period, and by allowing
averaging, the EPA is effectively allowing compliance to be measured based upon a far larger number of
test runs, and operating hours - over which there will be far less variability and thereby allows sources
to emit hazardous pollution well in excess of the actual emissions of the best performing similar plant or
plants. The commenter states that the EPA should, as a general matter, establish standards that are
consistent in their form with those the agency uses when it assesses variability; its standards will not
otherwise reflect the performance of the best source or sources. According to the commenter, in this
instance, if the EPA allows units to combine their emissions for purposes of compliance, it should re-
calculate the variability associated with multiple-unit emissions, and establish a corresponding
"discount" in the standards for multiple units.

Response to Comments 70-75: The agency considered the commenters' suggestions but did not change
the rule to include use of a discount factor. As mentioned elsewhere, the agency agrees with the
suggestion that other safety factors in the rule obviate the need for a discount factor. The agency notes
that while emissions averaging could begin upon promulgation of the rule, it must start within 3 years of
promulgation. Finally, the agency disagrees with the suggestion that another variability component need
be considered for those EGU owners or operators who choose to engage in emissions averaging; the
current UPL analyses was developed to take factors such as those mentioned by the commenter into
account.

7. Facility averaging provisions should be modified to allow for alternative mass limits.

Comment 76: Commenter 17877 supports the idea of facility emission averaging, in as much as it may
provide real operational flexibility to sources. According to the commenter, however, the averaging
provisions of the proposed rule are so restrictive that they are unlikely to be used, and the 10 percent
"discount factor" of which the EPA is seeking comment will certainly deter averaging since artificially
lowering the standards will render the already complicated task of compliance even more difficult. The
commenter states that there is no legitimate reason for imposing a 10 percent penalty on sources that
seek to average emissions.

The commenter states that total emissions from a single facility have the same impact on public health
regardless of whether each unit at the facility meets the MACT limits or all units meet the MACT limits
in the aggregate — the total emissions from the facility are the same, and the 10 percent penalty on
operational flexibility has no public health benefit.

Comment 77: Commenter 18788 finds that in practice the draft model for source averaging would
penalize a facility when the best performing units are not operating. The commenter states that at a
facility where eligible units are combined under a weighted average emission rate, the emission rate

363


-------
average of the operating units will calculate higher when the best performing unit(s) are shut down and
emitting no HAP what-so-ever, and that this effect is especially pronounced when the best performing
unit is the largest among the group.

The commenter presented Example 1 below of a hypothetical facility, with all units online and in
compliance with the total particulate limit of 0.03 lb/MMBtu on a facility basis.

Example 1: All Units Online

In the second example, the newest and best performing unit is offline and mass emissions from the
facility are decreased by as much as 30% as compared to Example 1, but the facility is now out of
compliance with the total PM limit on a weighted average basis. According to the commenter, the
facility is therefore penalized for emitting less.

Example 2: Unit 3 Offline

Commenter 17877 suggests that EPA could address the averaging penalty in one of two ways: First, the
EPA could allow for the facility total heat input to be fixed at all times in the denominator of the
averaging equation for each unit. According to the commenter, for the hypothetical facility, the hourly
averaging calculation would be as so:

(Unit 1 Emission Rate * Actual Heat Input / 12,000)

(Unit 2 Emission Rate * Actual Heat Input / 12,000)

+ (Unit 3 Emission Rate * Actual Heat Input / 12,000)

Facility Average Emission Rate

The commenter states that according to this method, the facility is actually encouraged not to operate
units and emit less, and enforceability is strengthened and facility compliance is simplified since the
MACT limit can be clearly and consistently compared to the Facility Average Emission Rate at all
times. According to the commenter, as currently drafted, the facility average method is of little use and
creates a constant moving target for the agency and the regulated facility.

The commenter states that as an alternative, or in addition to the above, the rule could be written to
include an alternate mass emission limit for the facility. According to the commenter, in this case, the
annual mass emissions would be based on the allowed emission rate multiplied by the hourly heat input
of the unit over the course of a year (included in document).

The commenter states that both of the proposed changes to the facility averaging provisions listed above
fit squarely within the generally applied limits on the "scope and nature" of past rulemakings where
facility averaging is allowed. The commenter asserts that if the EPA is serious about providing
operational flexibility to facilities, then it must make substantial revisions to the averaging provisions of
the rule.

Response to Comments 76 and 77: : While the agency appreciates support for use of emissions
averaging without a discount factor, as mentioned elsewhere, the agency disagrees with the commenter's
views on the suitability of mass emissions for emissions averaging in this rule. The agency believes it

364


-------
would be inappropriate to introduce a new emissions limit based on mass only without appropriate
notice and comment on that suggestion. The rule's emissions limits remain unchanged. Should an EGU
owner or operator find the rule's existing emissions averaging procedures too stringent, he or she should
choose from the other compliance determination options.

365


-------
5C03 - Compliance: Fuel switching

Commenters: 16705, 17400, 17697, 17725, 17737, 17756, 17774, 17810, 17813, 17820, 17840, 17852,
17853, 17881, 17901, 17902, 17904, 17912, 17930, 18038, 18421, 18428, 18477, 18502, 18575, 19536,
19537, 19538, 18023

1.	Coal switching.

Comment 1: Several commenters (16705, 17400, 17697, 18038, 18575) point out that the proposed
rules assume that all coal types can still be used with available control technologies, but this may not be
the case. Such fuel switching from one coal type to another or fuel blending can be very expensive for a
municipal utility. Commenter 17697 adds that Guam is very restricted in fuel choices, and the GPA must
rely on oil for the near to midterm.

Comment 2: Commenter 18023 states that while decisions will be made to change the fuel supply for
some coal-fired units to natural gas-fired units based on the economics of available alternatives, it is
important to note that any decisions to change the fuel for an existing coal unit to natural gas or oil
would never be economic when compared to business as usual and would only occur because of the
requirements imposed by the proposed rules. Commenter states that changing fuel to natural gas also
presents important reliability considerations, including the capability for back-up fuel, such as oil, in
case of supply disruptions because natural gas cannot be stored on-site.

Comment 3: Commenter 17881 states that rail congestion and increasing transportation cost limit the
viability of the PBR coals option. Commenter adds that the chlorine content in western coal can vary
widely, making DSI a non-viable option for every unit.

Comment 4: Commenter 18421 cites the URS report which points out that coal switching is potentially
an option for compliance for some coal units burning lignite. Commenter adds that plants burning Texas
lignite will need to remove mercury at high levels to comply, and switching to western subbituminous
coal could significantly decrease mercury emissions due to Hg content of coal and improved ACI
performance.

Response to Comments 1-4: The EPA has not mandated fuel switching as a compliance option - nor
has the EPA used fuel switching to set emission floors or as a 'beyond-the-floor' option. The EPA does,
however, recognize that fuel switching is a legitimate compliance option that will be considered and
likely implemented by some facilities. Low sulfur sub-bituminous is now widely available and is burned
across the contiguous U.S. states to comply with SO2 limits. The EPA is aware of facilities in the East
(e.g., Florida, Georgia, Maryland, Connecticut, and Delaware) and in the West (e.g., Oregon,
Washington, and Arizona) that are firing or co-firing sub-bituminous coal. The EPA maintains that
control technology options are available to retrofit existing facilities to allow them to meet the existing
source emission limits without having to switch fuels.

2.	Opposition to fuel switching to natural gas.

Comment 5: Commenter 17881 states that natural gas transmission and storage infrastructure does not
exist to support the option of fuel switching to natural gas and adds that it cannot be put in place within
the constraints of a MACT time-line.

366


-------
Comment 6: Commenter 17881 states that exclusive use of natural gas at Consumers Energy's Karn's
Oil/Gas Fired Units - 3 & 4 (currently rated at 638 MW each, but less than 5 percent capacity factor)
would require these units to be de-rated 50 percent to about 300 MW each or have significant boiler
modifications to allow the firing of 100 percent natural gas at the boiler design capacity. According to
the commenter, the natural gas supply infrastructure would have to be significantly upgraded in order to
supply the volume of gas needed to operate the units at full capacity. The commenter states that these
units are called on only when electric load demand is high, as in the summer of 2011, and perform a
vital role to meet load demand.

Comment 7: Commenter 17901 states that natural gas units are not covered under the proposed Utility
MACT, and the EPA has given no indication that it will establish any stringent limits for natural gas
units comparable to those required from coal-fired units. Commenter states that the proposed MACT is a
continuation of an ongoing pattern of disparate treatment for coal utilities. Commenter disagrees with
the EPA's consideration of requiring fuel switching from coal to gas as a potential "beyond-the-floor"
control, although the EPA properly rejected the use of natural gas as a control option. Commenter
disagrees with consideration of fuel switching to an entirely different fuel with totally different delivery
systems, types of combustion, and emissions control systems to be a feasible option at all. Commenter
supported this point by citing the EPA's statement that, "natural gas pipelines are not available in all
regions of the U.S., and natural gas may not be available as a fuel for many EGUs." Commenter also
states that the EPA notes that the relative cost of a switch to natural gas from coal was many times
higher than the cost to install additional control equipment on coal plants.

Comment 8: Commenter 17912 states that switching from coal or oil to natural gas is not appropriate as
a control option and not feasible for many units and concurs with the EPA's proposal not to require fuel
switching as a "beyond-the-floor" option for the EGU MACT. Commenter agrees with the EPA reasons
for not requiring fuel switching to natural gas, which is delivered through pipelines, is not available
everywhere in the U.S., where pipelines do exist, natural gas may not be available throughout the year
(e.g., the heating season), and the cost of such fuel switching would be prohibitive in many
circumstances. Commenter urges the EPA not to modify or reconsider this proposal not to use natural
gas as a "beyond-the-floor" option.

Response to Comments 5-8: The EPA has not mandated fuel switching as a compliance option - nor
has the EPA used the potential for fuel switching to set emission floors or as a "beyond-the-floor"
standard. The EPA does, however, recognize that fuel switching is a legitimate compliance option that
will be considered and likely implemented by some facilities. However, the EPA maintains that control
technology options are available to retrofit existing facilities to allow them to meet the existing source
emission limits without having to switch fuels.

3. Concerns with ability to meet liquid fuel-fired limits.

Comment 9: Commenter 17912 disagrees with the EPA's suggestion that oil-fired units have the
compliance option of using low-HAP oil, citing that the EPA fails to identify anywhere in the ICR fuel
data any oil sufficiently low in HAP that a liquid fuel-fired boiler has used this method to comply.

Comment 10: Commenter 18502 points out that compliance with the proposed metals and HC1
limits by residual oil-fired EGUs assumes a level of consistency in flue gas composition that has not
been demonstrated as compared to coal-fired units. According to the commenter, there are some key
differences between coal and oil relative to compliance with the proposed emission limits:

367


-------
a.	The concentrations of metals and chlorine in coal can be measured, but are generally below analytical
detection limits for residual oil. The commenter states that during ICR testing, quantifiable levels of
chlorine were detected in the fuel used by just two of the eight EGUs tested and nickel was the only
metal detected in more than a quarter of the samples.

b.	Coal is supplied to an individual EGU from suppliers in defined geologic and geographic areas
that have definable fuel characteristics, whereas deliveries of crude oil to refiners and fuel oil to
consumers are based on international market conditions. The commenter states that while fuel
specifications regarding some parameters are possible (e.g., sulfur content), use of fuel
specification to control chlorine and metals content of oil is untested.

c.	Air pollution control technologies to reduce criteria pollutant emissions from coal-fired boilers is well
documented and can be used to estimate reductions in HC1 and metals emissions; however, control
technologies are less commonly used with oil-fired boilers, and the correlation between reductions in
PM and reductions in metals is not as well defined.

Response to Comments 9 -10: As noted elsewhere in this document, EPA has reassessed its analysis of
the oil-fired EGU data. The EPA believes the limits in the final rule, which are based on emissions data
from existing liquid oil-fired EGUs, are achievable by oil-fired EGUs. Further, EPA is providing for an
alternate compliance assurance alternative for the acid gas HAP of measuring the moisture in the oil in
lieu of testing for HC1 and HF.

4. Opposition to conversion of liquid-fired EGUs from RFO to DFO.

Comment 11: Commenter 17725 points out several challenges to converting liquid-fired EGUs from
residual fuel oil (RFO, oil grades No. 4, No. 5, and No. 6) to distillate fuel oil (DFO, oil grades No. 1
and No. 2), and states that these oils have distinct separate characteristics and they are not
interchangeable:

a.	According to the commenter, different ASTM Standard D396-10, Standard Specifications for Fuel Oil
(Standards) include differing requirements (e.g., flash point, viscosity pour point) that affect different
storage requirements. According to the commenter, many RFO storage facilities have heated storage
tanks, an oil recirculation system, and heated conveyance piping to the boiler, and conversely, the
storage of DFO does not require heated systems.

b.	According to the commenter, combustion of RFO and DFO is not interchangeable within a boiler, and
a fuel switch to DFO requires significant modification. According to the commenter, because of the
different physical characteristics, the combustion process equipment is designed and installed to reflect
the characteristics of the fuel being combusted. The commenter states that boiler burners and burner tips
used to combust RFO cannot be used to combust DFO and that the converse is also true. The commenter
states that once introduced to the boiler, proper combustion of RFO can only be obtained by using steam
atomization or mechanical atomization, and conversely, combustion of DFO does not require an
atomization system.

c.	According to the commenter, an EGU using RFO will not have the same output (steam flow and the
resulting generation) using the same amount of DFO because of the lower heating value of DFO.
According to the commenter, the lower output of a DFO unit would be approximately 15-20 percent;
for example, a rated 200 MW unit using RFO would only be a 160 - 170 MW unit using RFO.

368


-------
d.	According to the commenter, conversion to DFO would entail modifications to the boiler combustion
system, as well as a conversion of the oil storage tank system, including replacement of burners and
burner tips and modifications to the burner management system. The commenter states that prior to
performing the physical changes, a boiler combustion study must be performed to ensure the burners are
properly designed for the boiler's configuration.

e.	According to the commenter, to prevent contamination from RFO, an existing RFO storage tank and
the associated piping must be cleaned.

f.	According to the commenter, change out of the piping and pumps are required so that the required
amount of DFO (which has a lower heating value) can be delivered to the boiler to maintain full load
capability.

g.	According to the commenter, a spill or leak of DFO will tend to flow further and faster than a spill or
leak of RFO, due to the lower viscosity.

h.	According to the commenter, many existing storage tank systems would need retrofitting to provide
adequate secondary containment for the lower viscosity DFO to address regulatory requirements for fuel
storage (i.e., SPCC, OPA-90). According to the commenter, this is a significant undertaking for large
RFO tanks, as they typically use earthen secondary containments, since RFO does not permeate into the
soil when spilled; whereas, converting to DFO storage would require expensive impermeable liner
installation and other changes. Commenter 17725 cites an example cost estimate for liner installation for
a relatively small two million gallon tank being from $500,000 to $800,000 and adds that their Oswego
facility has multiple 11 million gallon tanks, the cost of which to line one of these tanks would be on the
order of two to three million dollars.

i.	According to the commenter, the capital investment for a conversion to DFO is site specific

but, NRG estimates that the conversion cost for their facilities ranges from $12 - 17/installed kW per
site, and this is only for the capital expense portion.

j. According to the commenter, there are additional costs for testing the unit to ensure that the
conversion will allow the EGU to meet the emission rate (prior to the actual compliance stack test). The
commenter states that the tuning and testing will require EGU full load operations for approximately 40
hours. A 400 MW unit can consume approximately 500 gallons per minute of fuel, and that for the 40
hours of tuning/testing, this relates to 1.2 million gallons of fuel, or approximately 29,000 barrels of
fuel. The commenter states that additional fuel use is required for the start-up and ramp up to full load
and shut down of the unit. The commenter states that the additional cost for the 29,000 barrels of DFO is
over $500,000, based on the 5-year average price presented (Commenter included Table 2.3.2, Five-
Year Average Fuel Prices at New York Harbor, Docket No. The EPA-HQ-OAR-2009-0234).

k. The commenter states that beyond the capital expenditures to retrofit units for DFO, the use
of DFO rather than RFO will increase the dispatch price of the EGU. According to the commenter, for
an EGU with a 10,000 Btu/kW-hr heat rate, the dispatch price for the unit based on fuel alone will
increase between 35 and 45 percent. The commenter states that as oil-fired EGUs are generally high on
the supply curve due to their relatively high heat rates, they are primarily dispatched for reliability at a
low level in preparation for spikes in demand (when their output will be increased), to cover for known
outages of lower cost units, or to provide transmission support. The commenter states that conversion
to DFO will increase their production costs up to 45% or more and put significant upward pressure on
electric costs during times of system duress.

369


-------
1. According to the commenter, conversion to DFO presents compliance risks for EGUs, as compliance
is based on the assumption that the source's emissions will be in the same range as those DFO-
fired units setting the standard. The commenter states that it is highly doubtful that an engineering and
construction firm would provide a guarantee that a conversion to DFO would in fact meet the proposed
total metal limits. According to the commenter, the rule does not provide an exemption or waiver for
an EGU that has been converted to a lower emitting liquid fuel and still cannot meet the total metal
limit. The commenter states that faced with the possibility of making a significant capital investment
with no assurance of ultimately achieving compliance, the EGU may be forced to retire as the
uncertainty is too great. The commenter states that EGUs that may or could comply would simply not
make an investment that large without reasonable assurance of being able to comply rendering
unintended outcomes of the rule's primary objective.

Response to Comment 11: The EPA acknowledges that capital expenditure may be needed to be able
to convert from residual oil to distillate oil. However, we would also note that other commenters indicate
that the switch is not as extreme or burdensome as commenters here note. Further, we are not
subcategorizing distillate vs. residual oil in the final rule. We note that all of the distillate oil-fired EGUs
for which we have data are in the limited-use subcategory noted elsewhere in this document. The MACT
floor pool for liquid-oil fired EGUS is comprised of sources burning residual oil-fired EGUs with ESPs.
Therefore, EPA maintains the final limits are achievable by residual oil-fired EGUs without the need for
oil switching, although such switching is always an option to an EGU that does not want to install PM
controls.

5. Opposition to use of proposed rule/limits to necessitate fuel switching.

Comment 12: Commenters 17813 and 17930 discourage the setting of limits that are so low as to
possibly necessitate fuel switching, stating that this would be a requirement found nowhere in the CAA,
is contrary to decades of precedent, and would set a dangerous policy that would undermine regional
electric reliability and affordability. Commenters add that lignite-burning power plants are mine-mouth
power plants wedded to their mines, and a switch to subbituminous coal to meet proposed emission
limits would mean sacrificing significant financial investments in fuel delivery, transportation, and
storage, not to mention boiler design. According to the commenters, boilers are designed for specific
types of fuel, as well as ranks within a fuel type, and there are limits due to the heat values and amount
of coal being burned that restrict lignite power-plants from increasing non-lignite coal consumption. The
commenters state that these issues were obviously considered and given weight when the EPA
developed the subcategory for <8,300 Btu/lb coal.

Comment 13: Commenter 17840 states that the EPA should articulate how a future plant can comply
with all of the proposed standards, and draws a conclusion that the EPA is proposing a beyond-the-floor
fuel switching measure for new sources, while inconsistently rebutting mandating fuel switching from
coal to natural gas as "an unreasonable regulatory option."

Comment 14: Commenter 17930 states opposition to requirements that impose fuel switching and notes
that fuel switching is not a viable option for many lignite units in Texas. Commenter states that for
many, the necessary infrastructure (e.g., rail lines, unloading stations, transport areas) does not exist to
begin burning other types of coal. Commenter states that the EPA's cost estimates for facilities to switch
to other coal types and construct this infrastructure is incomplete and provides the following points as
flaws in the EPA cost analysis:

370


-------
a.	According to the commenter, the EPA's cost estimate does not include all requisite infrastructure
costs (e.g., dust collection, conveyors, fire protection, ventilation, ESP performance, water cannons,
significant boilers modifications to burn 100 percent PRB coal.

b.	According to the commenter, the EPA has not adequately taken into consideration the potential
escalation of PRB coal and transportation prices once the coal fleet responds to this and other pending
regulations (e.g., the Cross-State Air Pollution Rule [CSAPR]).

c.	According to the commenter, the EPA's cost prediction for the "beyond-the-floor" limit is far too low
because the EPA fails to include the cost of installing fabric filters in the price analysis. The commenter
states that the EPA's cost analysis assumes that all units within this subcategory will require capital
investments in fabric filters that are attributable to the proposed MACT standard for PM (as a surrogate
for non-Hg metallic HAP). According to the commenter, this analysis determines the marginal capital
costs attributable to the BTF option requiring installation of ACI systems to reduce Hg emissions to 4.0
lb per trillion Btu (Commenter cites a Beyond the Floor Letter, Shelley Johnson to Bill Maxwell,
included in Docket No. The EPA-HQ-OAR-2009-0234). Commenter points out that this assumption is
flawed for two reasons:

1.	Fabric filters will not necessarily be installed at these units. According to the commenter, while
surrogates may be a means of compliance for lignite-fired EGUs, the rule still allows for the control of
the non-Hg metallic HAP themselves, which may not require a fabric filter.

2.	The EPA cannot exclude the costs of a control technology installed to control Pollutant A (which
incidentally controls for Pollutant B), while counting the benefits of the limitation on Pollutant B. The
commenter states that benefits cannot be counted twice, while costs only counted once.

Response to Comments 12 -14: The EPA has not mandated fuel switching as a compliance option -
nor has the EPA used fuel switching to set emission floors or as a 'beyond-the-floor' option. The EPA
does, however, recognize that fuel switching is a legitimate compliance option that will be considered
and likely implemented by some facilities. Low sulfur sub-bituminous is now widely available and is
burned across the contiguous U.S. states for compliance with existing S02 standards. The EPA is aware
of facilities in the East (e.g., Florida, Georgia, Maryland, Connecticut, and Delaware) and in the West
(e.g., Oregon, Washington, and Arizona) that are firing or co-firing sub-bituminous coal. Control
technology options are available to retrofit existing facilities to allow them to meet the existing source
emission limits without having to switch fuels. We maintain that the final limits were established in
accordance with the statute and have considered costs to the extent required.

6. Request for expansion of provisions for exclusion from requirements.

Comment 15: Commenter 17737 agrees with the provision to exclude units that did not fire coal or oil
for more than 10.0 percent of the average annual heat input during the previous 3 calendar years or for
more than 15.0 percent of the annual heat input during any one of those calendar years from
subpart UUUUU. However, Commenter recommends that this be expanded to include units that have
burned coal for more than 10.0 percent during the 3 years immediately following promulgation of the
final rule, or 15 percent during any one of those years, but elect to switch to burning natural gas for at
least 90 percent of the annual heat input beginning prior to the date the units must be in compliance.
Commenter adds that this provision should not require the unit(s) to be modified by making the coal
burning capabilities inoperable or needing to modify the permit to remove the coal burning capabilities
and cites that the proposed definition of "fossil-fuel fired" unit (76 FR 25020) seems to require that the

371


-------
owner physically remove all coal burning capabilities and that coal burning would not be allowed in the
permit. Commenter states that they (TEP) own and operate H. Wilson Sundt (Sundt) Unit 4, which is
capable of burning coal and/or natural gas, and TEP would like to have the option to use this flexibility
to bum different types of fuel. TEP would like to maintain the ability to continue to bum coal in this unit
for the next 3 years but switch to natural gas prior to the date the unit would need to be in compliance
with subpart UUUUU. According to the commenter, under the present proposed rule, TEP would still be
subject to the subpart UUUUU monitoring, reporting, and recordkeeping requirements even if it ceases
to burn coal prior to the compliance date, posing an unnecessary regulatory burden without
environmental benefit. Commenter suggests that if a unit is capable of burning different types of fuel,
including coal, then the owner/operator should be required to maintain records of the quantity and type
of fuel burned to assure that at least 90 percent or more of the heat input is from natural gas and that the
operating permit would be revised to require the owner/operator to apply for a permit revision to comply
with the requirements of subpart UUUUU prior to resuming to burn coal in quantities >10 percent of
heat input.

Comment 16: Commenter 17756 cites that in order to convert a unit to natural gas or biomass and be
exempt from the proposed Toxics Rule, the owner would need to convert the unit to 100 percent
biomass or natural gas within three years and remove all capability to burn coal or oil. Commenter
suggests that alternatively, the unit could convert to biomass or natural gas by 2012 and ensure that the
heat input from coal or oil in 2012, 2013, and 2014 is below the annual 15 percent heat input
requirement and the 3-year requirement of 10 percent heat input.

Comment 17: Commenter 17756 recommends that the EPA revise the definition to change the "look-
back" period to begin three years after the unit's final compliance date. According to the commenter,
this change would not penalize a unit that switches to natural gas and retains the ability to combust coal
or oil for having burned coal or oil in the period before compliance. Commenter also suggests that a unit
that switches to natural gas and later switches back to highly controlled coal use should not be in
violation of the 3-year average for the years it was burning natural gas.

Comment 18: Commenter 17820 recommends that the EPA change the "look-back" period under the
applicability criteria for units that cease combustion of coal or oil to provide absolute assurance that
units converted to natural gas or biomass are exempt from the rule.

Comment 19: Commenter 17902 recommends that section 63.9981 further clarify that existing coal or
oil-fired EGUs that combust natural gas as of the required compliance date are not subject to the
requirements of subpart UUUUU.

Comment 20: Commenter 17904 recommends that the EPA should revise the applicability language to
allow generators to retain the option of simply restricting dual fuel-fired units as a compliance strategy -
but they should not be forced to begin fuel restrictions immediately. According to the commenter, this
would amount to making the compliance date equivalent to the effective date of the rule. Commenter
recommends that the EPA should revise the definition to clarify that any unit which actually burns 90
percent natural gas during a calendar year is excluded from compliance obligations, irrespective of
whether the unit fired some large percent of fossil fuel prior to the effective date.

Comment 21: Commenter 18428 supports the provision in the EGU MACT that a unit that burns on
average at least 90 percent of fuel as natural gas during, "the previous 3-year period," is considered
natural gas-fired and therefore not subject to the EGU MACT. However, the commenter requests that
the EPA add to this provision that units that switch to natural gas by the compliance deadline and

372


-------
continue to operate that way thereafter should also not be subject to the oil-fired EGU MACT
requirements.

Response to Comments 15-21: As noted elsewhere in this document, the EPA has revised the
definitions to account for the "look back" provision noted by commenters.

7.	One-year extension for compliance.

Comment 22: Commenter 17852 concurs that a 1-year extension can be appropriate when a utility is
undertaking a technically complex project, such as converting an existing coal-fired boiler to burn
natural gas or building a new NGCC, but only where the utility has timely gone about such action and
can demonstrate that such action does in fact require an extra year to comply. Commenter adds that there
are many things that utilities can do to achieve compliance within the 3-year time-frame, and cites the
following:

a.	Various sources have suggested that controls can be installed within the 3-year time-frame, including,
Exelon Corporation which has said in reference to the Boiler MACT, "We know we can install controls
in three years because many plants have already done it in that timeframe."

b.	Existing, high-efficiency NGCC units are underutilized and can immediately increase generation,
allowing for older, uncontrolled coal plants to be retired, without an extension of the MACT regulatory
time-frame.

c.	Various sources have shown that new natural gas generation can be built within the mandated 3-4 year
time-frame.

Response to Comment 22: Responses to comments of this type are provided in the preamble to the
final rule.

8.	Blending fuels.

Comment 23: Commenter 17774 points out that the proposed Utility MACT definitions of various
regulated subcategories seem to overlap in cases where a unit is not exclusively burning coal and
requests clarification in the regulation of sources which blend fuels to clearly delineate which standards
apply in cases where fuel blending is employed. Commenter cites an example where a coal-fired unit
which burns more than 10 percent petcoke could arguably either fall under the solid oil-derived fuel
subcategory or the coal-fired subcategory:

a. The commenter states that the proposed rule defines "oil" as "crude oil or petroleum or a fuel derived
from crude oil or petroleum, including distillate and residual oil, solid oil-derived fuel (e.g., petcoke)
and gases derived from solid oil-derived fuels (not meeting the definition of natural gas)." The
commenter states that the proposed rule further defines the "unit designed to burn solid oil-derived fuel
subcategory" as "any EGU that burned a solid fuel derived from oil for more than 10.0 percent of the
average annual heat input during the previous 3 calendar years or any one of those calendar years, either
alone or in combination with other fuels." According to the commenter, consequently, if a coal-fired
unit burns more than 10 percent petcoke, it could arguably fall into the solid oil-derived fuel
subcategory.

373


-------
b. The commenter states that however, the coal-fired subcategory also indicates that it includes units
burning petcoke. The commenter states that the proposed rule defines a coal-fired unit as a unit that
"burns coal or coal refuse either exclusively, in any combination together, or in any combination with
other fuels in any amount."

Commenter 17774 urges the EPA to clarify which standards apply to units burning coal and petcoke and
suggests that the EPA require affected sources to comply with the standard applicable to the majority of
fuel burned (e.g., greater than 50 percent).

Comment 24: Several commenters (19536, 19537, 19538) provides comment in response to the EPA's
request to comment on, "whether the proposed rule should address how sources that change fuel input
(e.g., burn solid waste or biomass), or otherwise take action that would change the source's
applicability.. .must demonstrate continuous compliance with all applicable standards." Commenters
state that EGUs designed to fire solid fossil fuels burn a mixture of coal types as well as other solid fuels
including solid oil-derived fuels (petcoke), biomass, and other solid fuels. Commenters suggest that any
subcategorization must be based on design differences which materially affect the availability of cleaner
fuels, or other methods of reducing pollution. Commenters take the position that where a plant
voluntarily (or for economic reasons) chooses to burn a high-polluting fuel, that decision should not
affect the standards applicable to the plant, with one exception: the agency is obligated to distinguish
between EGUs that are waste combustors (and thus subject to stricter standards governing
waste combustors) from EGUs that are primarily fossil-fueled. Commenters concur with the EPA's
proposed rule definitions for the solid fuel subcategories defining coal fired units as, "electric utility
steam generating unit meeting the definition of 'fossil fuel-fired' that burns coal or coal refuse either
exclusively, in any combination together, or in any combination with other fuels in any amount (76 FR
25122, Proposed section 63.10042 definitions). The commenters state that "Fossil fuel-fired," in turn, is
defined as, "to the extent that an EGU that is capable of burning primarily coal or other solid fossil fuels
to generate electricity, and also elects to co-fire biomass to meet some other statutory requirement, it
must continue to meet the MACT limits for the subcategory in which it is listed." Commenters add that
this is particularly important for biomass, as burning green wood produces more of various regulated
HAP than does burning coal (Commenters cite Figure 1 in Docket No. The EPA-HQ-OAR-2009-0234).
Commenters also add that it would be unlawful for the EPA to finalize a MACT subcategory that would
worsen the HAP emissions profile of the EGU beyond what it would be absent the biomass burning.

Response to Comments 23 - 24: As noted elsewhere in this document, the EPA has revised the
definitions to address commenters' concerns.

9. Disagreement That the EPA Did Not Use Best Available Data/Information to Support Fuel
Switching Analysis for Proposed Rule with Respect to Natural Gas

Comment 25: Commenter 17810 states that natural gas is currently under-utilized for power generation
and could be called into duty very quickly to provide clean energy and an immediate pollution
reduction. In addition to significant HAP reductions, the commenter states that emissions reductions in
NOx and SO2 can be realized from fuel switching (coal to natural gas) in the power generation sector.
Commenter recognizes that the EPA may not consider it realistic to require all coal plants to shift to
natural gas by setting a beyond-the-floor standard based on natural gas combustion; however, points out
that some owners and operators may find that converting to natural gas (retrofit, repowering, new
construction, or use of underutilized existing plants) is a cost-effective compliance strategy. Commenter
concludes that efficiency benefits of NGCC combined with natural gas and coal price projections
make NGCC clearly preferable to advanced coal-fired boilers for new base-load generation, citing IPM

374


-------
runs commissioned by commenter and review of the EPA's IPM results. Commenter cites that the EPA
shows in the IPM results that no new pulverized coal capacity is added through 2030, even in the base
case, while 68 GW of NGCC capacity is added under the base case assumptions and 75 GW of NGCC
capacity is added under the policy case assumptions through 2030 (EPA, IPM Analysis of the Proposed
Toxics Rule, March 2011, available at http://www.epa.gov/airmarkets/progsregs/epa-ipm/toxics.htmn.
Commenter states that it is important for the EPA to use accurate and current data to appropriately
characterize the most up-to-date natural gas infrastructure, supply, cost, and technology associated with
natural gas availability, and cites several areas of disagreement with the EPA's assumptions used in
development of the Proposed Rule:

a. For existing EGUs, Commenter 17810 cites that the EPA determined that fuel switching (coal to
natural gas) was not an appropriate beyond-the-floor option, citing two primary reasons: (1) natural gas
supplies are not available in some areas, and (2) increased fuel costs cause a unit's total incremental cost
of electricity (COE) to be significantly higher compared to the incremental COE of other options.
Commenter 17810 states that the EPA included only two documents to justify these conclusions
(.Technical Support Document [TSD] for the Transport Rule [sic], "Coal-to-Gas Conversion (C2G)"
(March 4, 2011) and Documentation Supplement for EPA Base Case v4.10_PTox - Updates for
Proposed Toxics Rule (March 2011), available at http://www.epa.gov/airmarkt/progsregs/epa-
ipm/docs/suppdoc.pdf Docket ID No. The EPA-HQ-OAR-2009-0234). Commenter states that both
these documents are associated with the cost of coal-to-gas conversion, but that neither addresses the
natural gas supply issue, and cites several references to the contrary (Docket ID No. The EPA-HQ-
OAR-2009-0234). Commenter 17810 states that there does not appear to be any evidence in the record
to support the conclusions that natural gas pipelines are not available in all regions of the U.S., natural
gas may not be available as a fuel for many EGUs, and even where pipelines provide access to natural
gas, supplies of natural gas may not be adequate, especially during peak demand (e.g., the heating
season). The commenter states that currently available information refutes the notion that there is
insufficient supply or inadequate infrastructure to support increased demand for natural gas for EGUs.
The commenter states that recent estimates from both the U.S. Energy Information Administration (EIA)
and the MIT Energy Initiative indicate sufficient supply to meet increasing demand for natural gas-fired
EGU capacity. According to the commenter, the actual delivery of supply to a specific consuming
market occurs hand-in-hand with the development of demand, and the delivery of supplies into the
vicinity of an EGU should not be expected to precede the demand from an EGU by a period of years.

i.	According to the commenter, the EPA's analysis of costs of constructing new laterals to distribute
gas to existing coal-fired units demonstrates that some coal-fired power plants have relatively
inexpensive access to natural gas mainlines, while other coal-fired power plants will have a more
difficult time accessing natural gas mainlines, but the analysis appears to contradict the EPA's
statement that natural gas pipelines are not available in all regions of the U.S. The commenter states
that the average coal-fired boiler at a power plant that does not already have access to natural gas
would need 57.4 miles of pipeline to meet natural gas demand, and the median pipeline requirement
is 26.2, meaning that 50 percent of coal-fired power plants would need 26.2 miles or less of
additional pipelines. The commenter states that while this suggests that in some cases access to
natural gas may require significant investment and construction, it does not support the idea that
natural gas is unavailable.

ii.	According to the commenter, the recently released INGAA Foundation study of midstream
infrastructure needs indicates that natural gas producers are playing an important role in funding
needed pipeline infrastructure as they compete to deliver their natural gas to markets.

375


-------
iii.	The commenter states that according to the U.S. EIA, "the U.S. natural gas pipeline network is a
highly integrated transmission and distribution grid that can transport natural gas to and from nearly
any location in the lower 48 States."

iv.	The commenter states that Department of Energy figures indicate that the interstate and intrastate
transmission network feeds over 1.1 million miles of regional lines in some 1,300 local distribution
utility networks, collectively delivering natural gas to 62 million customers in the U.S.

v.	According to the commenter, the natural gas industry has shown an ability to respond to changing
market conditions. The commenter states that according to EIA, 3,893 miles of new natural gas
pipelines were added in 2008 alone.

vi.	The commenter states that the recent INGAA Foundation study includes FERC data showing
from January 2000 to February 2011, interstate pipeline companies received approval to construct
over 16,000 miles of interstate pipelines and add an additional 14,600 miles of expansion pipeline.
According to the commenter, the INGAA Foundation projects similar development over the next
10 years.

vii.	The commenter states that according to a recent report issued by the MIT Energy Initiative on
the Future of Natural Gas ("MIT Natural Gas Report"), the production and delivery infrastructure of
natural gas in the U.S. is "both mature and robust." The commenter states that major changes in U.S.
gas markets have prompted significant additions to the country's pipeline network over the last
several years; between 2005 and 2008, pipeline capacity additions totaled over 80 billion cubic feet
per day (Bcfd), exceeding those from the previous four-year period by almost 100 percent. Additions
of 44.5 Bcfd in 2008 alone exceeded total additions in the five-year period between 1998 and 2002.
According to the commenter, MIT's Interim Report to the Future of Natural Gas noted, "On the gas
infrastructure side, concerns have been raised about the availability of gas pipeline capacity for the
additional gas requirements of this option [displacement of coal generation], but preliminary analysis
indicates that the industry has the ability to meet the needs for additional pipeline capacity." The
commenter states that the MIT Natural Gas Report concluded that: (a) there are abundant supplies of
natural gas in the U.S., despite their relative maturity, natural gas resources continue to grow; (b) the
role of natural gas is likely to continue to expand under almost all circumstances, as a result of
availability, utility, and comparatively low cost; and (c) increased utilization of

existing NGCC power plants provides a relatively low-cost short-term opportunity to reduce U.S.
carbon dioxide emissions by up to 20 percent in the electric power sector and significantly reduce
sulfur dioxide, nitrous oxide, particulates, and mercury with minimal additional capital investment in
generation and no new technology requirements.

viii.	The commenter states that the FERC also noted significant recent increases in the storage
capacity for natural gas. The commenter states that more than 107 Bcf of incremental working gas
capacity was added in 2009, including more than 50 Bcf in the Gulf region. The commenter states
that traditional production area storage allows suppliers to respond more adeptly to market signals,
and as a result, those signals are moderated. The commenter states that reporting on 2010 storage,
the FERC said, "Natural gas storage levels were high for much of the year and reached record levels
in November."

ix.	The commenter states that generally speaking, estimates of the available domestic supply of
natural gas have expanded significantly over just the past five years. According to the commenter, in
a 2009 Report addressing the supply of technically recoverable natural gas in the United States at

376


-------
2008	year-end, the Potential Gas Committee reported that the currently available total supply of
natural gas was 1,836 trillion cubic feet (Tcf), which represented an increase of 39 percent (516 Tcf)
over the Committee's year end estimate for 2006. The commenter states that in the 2011 Report, the
Potential Gas Committee increased this estimate to 1,898 Tcf. According to the commenter, the MIT
Natural Gas Report also reviewed U.S. gas resource estimates from several sources, including the

2009	Potential Gas Committee Report, and assumed a mean remaining resource base of
approximately 2,100 Tcf. The commenter states that the U.S. EIA recently estimated that annual
production of natural gas will increase by 25 percent from 2009 to 2035. According to the
commenter, many of these sources attribute this dramatic increase in recoverable natural gas supplies
in large part to the discovery of significant shale gas deposits and advances in technology for
recovery of gas from these resources.

x.	The commenter states that studies have concluded that not only is there an expanding supply of
natural gas, but due to declining costs of recovering that gas, domestic gas production is likely to
increase significantly. According to the commenter, as summarized in a recent report issued by the
Bipartisan Policy Center and American Clean Skies Foundation, "While estimates of supply have
increased, the cost of producing shale gas has declined as more wells have been drilled and new
techniques have been developed and field tested. The commenter states that the MIT study estimated
that between 250 and 300 Tcf of shale gas can be produced at prices below $8/MMBtu (in 2007
dollars), and more recently, ICF International estimated that almost 1,500 Tcf are available at
$8/MMBtu, while 500 Tcf are available at $4/MMBtu and 1,500 Tcf are available $5/MMBtu (ICF
Figure 1 included in Docket EPA-HQ-OAR-2009-0234).

xi.	According to the commenter, significant changes have occurred both with respect to natural gas
supplies and storage infrastructure over the past 10 years that alleviate heating season supply
concerns. With respect to storage, the commenter states that FERC reports in the State of the
Markets Report that in late November 2009, U.S. inventories were 99 percent of capacity, suggesting
that there is sufficient gas reserve capacity to address demand spikes during the heating season. The
commenter states that greater reliance on shale extraction methods in the production process helps
mitigate concerns about responsiveness on the supply side when demand increases. According to the
commenter, unlike conventional production, in which a producing well needs to be kept "on" in
order to maximize the amount of recoverable gas, production from shale wells is far more elastic,
allowing producers to ramp up production in response to price signals, thereby helping to avoid the
dramatic price swings that happen when it takes longer for production levels to respond to changes
in demand.

b. For new EGUs, Commenter 17810 states that the EPA fails to consider best available data on supply
and cost when identifying beyond-the-floor options. According to the commenter, in making the
determination that fuel switching to natural gas is not a reasonable option, the EPA falls back on a
generic statement that natural gas supplies are not available in some areas; whereas, commenter posits
that it establishes with the above references that natural gas is widely available throughout the country
and new power plants can be sited with pipeline capacity and proximity as a key consideration.
Commenter states that the EPA also suggests that "limited emissions reductions in combination with the
high cost of fuel switching and considerations about the availability and technical feasibility makes this
an unreasonable regulatory option that was not considered further." Commenter states that this
statement, without supporting data or discussion, is not sufficient to eliminate the consideration of a
beyond-the-floor option. Commenter 17810 states that they are not aware of technical challenges
associated with designing and constructing a new unit to combust natural gas instead of coal, and
suggests that the EPA evaluate the cost of a new NGCC unit for providing base load power as compared

377


-------
to a new advanced coal-fired boiler. Commenter cites the EPA's modeling in support of the rule, which
projects no new advanced coal-fired boilers to be constructed through 2030, even in the base case
scenario without imposition of the rule.

c. Commenter 17810 cites other regulatory contexts where it says that EPA has read similar provisions
of the CAA to include the use of lower-emitting processes and practices, including switching to cleaner
burning fuels:

i.	BACT Guidance issued in March 2011 includes switching to clean fuel as a "control option" for
purposes of performing a BACT analysis under the PSD program.

ii.	BART guidance under the Regional Haze program includes inherently lower emitting processes,
such as processes using cleaner fuels, as "potentially applicable retrofit control technologies."

Comment 26: Commenter 17852 states that switching from coal-fueled electric power generation to
generation from natural gas or renewable energy can achieve substantial reductions in toxic air
emissions, stating that natural gas plants emit no mercury and negligible other HAP in contrast to coal.
Commenter adds that numerous modern, high-efficiency NGCC plants with significant unused capacity
are available to replace existing coal-fired generation and that dramatically expanded U.S. natural gas
reserves and infrastructure have reduced gas price volatility (citing several references in the Docket
EPA-HQ-OAR-2009-0234). Commenter 17852 recommends that the EPA re-evaluate the docket and
issue specific guidance and indicate in the preamble to the utility MACT final rule that fuel switching to
natural gas is a means to comply with the standard, providing guidance how various types of fuel
switching to natural gas can allow coal/oil units to comply, including:

a.	Converting existing coal boilers to natural gas;

b.	Retiring coal plants and building new natural gas plants (either at the same location or a new
location);

c.	Increased co-firing with natural gas; and

d.	Increasing use of existing, underutilized natural gas power plants.

Commenter 17852 states that the EPA made several unsupported assumptions in rejecting natural gas as
a compliance option and cites several references (included in Docket EPA-HQ-OAR-2009-0234) to
support this point:

a. Commenter 17852 states that, in comparing costs for fuel switching to natural gas, the EPA only
focuses on one type of fuel switching (converting existing coal boilers to natural gas, which results in a
loss in boiler efficiency). Commenter states that a more logical evaluation would be to compare the
expensive retrofits facing existing coal plants to retiring the aging plants and either using existing
natural gas generation from unused capacity or building a new NGCC (at same location or new site).
Commenter adds that the EPA's analysis also ignores the possibility of co-firing natural gas in coal or
oil-fired boilers. Commenter conducted such an economic evaluation and found that the break-even gas
price for increasing use of existing NGCC vs. retrofitting coal plants with a scrubber and SCR is
approximately $6/MMBtu. Similarly, commenter's evaluation found that the break-even price for
building a new NGCC is approximately $5.50/MMBtu. According to the commenter, thus, using the
natural gas prices that the EPA assumes in their fuel switching analysis ($5.74/MMBtu), increasing the

378


-------
use of available capacity from an existing NGCC is the economical choice, and building a newNGCC is
virtually equivalent. Commenter adds that the economics for using natural gas improve when including
additional costs that may be imposed on coal-fired power plants under other regulatory initiatives.

b.	Commenter 17852 states that the EPA finds coal to gas retrofits more expensive than other retrofit
options based on fuel prices of coal at $2.13/MMBtu and natural gas at $5.74/MMBtu, despite the
capital and O&M costs of the coal to gas retrofits being less expensive than other options.

c.	Commenter 17852 states that it should be recognized that the EPA's assumed natural gas price
($5.74/MMBtu) only assumed installation of scrubbers and SCR, but if additional controls are required
(e.g., coal ash, cooling water issues), it can become more economical to shutter old coal plants and build
new NGCC plants.

d.	The commenter states that with respect to co-firing with natural gas, the EPA notes that, "For the oil-
fired subcategory, we did not include data obtained from EGUs co-firing natural gas in the existing
source MACT floor analysis because those emissions are not representative of EGUs firing 100
percent fuel oil (76 FR 25045). Commenter 17852 recommends that the EPA should clarify in the
guidance that co-firing with natural gas can reduce the emissions of either coal or oil-fired units and
may be an effective means of compliance.

e.	Commenter cites that the EPA has found that regulation of HAP emissions from natural gas power
plants, "is not appropriate or necessary because the impacts due to HAP emissions from such units are
negligible."

f.	Commenter refutes the EPA's contention that natural gas may not be a cost effective option, stating
that fuel switching to natural gas is made more feasible by the fact that dramatically expanded U.S.
natural gas reserves and infrastructure have reduced gas price volatility and are projected to make
natural gas affordable for the foreseeable future. Commenter cites that the EPA RIA for the proposed
rule includes projections that natural gas prices are not expected to exceed their 2008 Levels through
2035 and that the EPA projects that the proposed MACT standard would increase power sector
delivered natural gas prices by only about 1% percent from 2015-2030, which is a negligible increase
and shows the ability of natural gas to provide fuel to power plants without dramatically increasing
natural gas prices (Figure 1, 2010 to 2011 Annual Energy Outlook of the EIA included in Docket EPA-
HQ-OAR-2009-0234).

g.	Commenter 17852 cites their own reports and studies, adopted by a task force that represented natural
gas producers and distributors, consumer groups, large industrial users, and independent experts, which
found that abundant natural gas supplies coupled with increased storage and import capability, as well as
the ability to use long-term contracts and hedging arrangements, provide for a stable natural gas price
horizon and opportunity to expand use in the U.S. Commenter states that the EPA must take into
account their recent studies, which show that available gas-fired generation capacity exists in most
regions of the U.S. According to the commenter, their report found that in 2008, CCGT plants
operated with only a 33% capacity factor. If only the more efficient group of CCGT plants (heat rate

of 9,000 Btu/kWh) were operated at 60% of capacity instead of at 33 percent, ACSF's report (which
also cited a MIT report) indicates that could replace up to 60,000 MW of out-of-compliance
base load units that may be retired. The commenter states that the geographic distribution of
this available CCGT capacity is rather well aligned with the location of most vulnerable coal-fired units
(Figure 2, Docket EPA-HQ-OAR-2009-0234).

379


-------
h.	Commenter 17852 cites that the MIT report also found that there is sufficient surplus NGCC capacity
to displace roughly one-third of U.S. coal generation. The commenter states that according to MIT,
substitution of this NGCC capacity would reduce CO2 emissions from the power sector by 20 percent
and yield a major contribution to the control of criteria pollutants.

i.	Commenter refutes the EPA's contention that natural gas pipelines are not available in all regions of
the U.S., citing the EPA's own data. The commenter states that as part of the rulemaking, the EPA
undertook an analysis for coal boilers in the U.S. to "determine the miles and associated cost of
extending pipeline laterals from each boiler to the interstate natural gas pipeline system." According to
the commenter, this study found that the median connection length is only approximately 26 miles and
the median incremental cost is only approximately $14 million. The commenter states that

given that environmental retrofits for coal plants may cost hundreds of millions of dollars, $14
million for the median cost of a new gas lateral connection is comparatively minor. Commenter adds
that the EPA may have used assumptions that overstated the length and cost of these new gas
connections. Commenter also cites that the Department of Energy (DOE) has found that that natural
gas lines can, "deliver fuel to power plants in most locations in the lower 48 states." Commenter
recommends that the EPA correct the record.

j. Commenter refutes the EPA's contention that, "even where pipelines provide access to natural
gas, supplies of natural gas may not be adequate, especially during peak demand (e.g., the heating
season)." Commenter points out that the development of shale gas has vastly increased onshore gas
production, gas storage capacity has increased over the last few years, and the FERC has been
responsive to the need for additional pipeline capacity to bring gas to new markets. Commenter
acknowledges that, while it is possible that unforeseen emergencies may create temporary curtailment,
these types of emergencies are manageable, and not unlike other energy delivery issues that occasionally
occur.

Comment 27: Commenter 17853 states that the EPA has the authority granted in section 112 of the
CAA to consider fuel switching as an alternative to achieving emission reductions during the
development of the Utility MACT and refutes the EPA's statement in the preamble that "supplies of
natural gas may not be adequate" with the following points:

a.	According to the commenter, at current consumption rates, North America has over a 100-year supply
of natural gas.

b.	According to the commenter, natural gas drilling and extraction technologies (including shale gas)
have dramatically improved over the last 5 years, and the lead time to respond to increased demand has
been significantly decreased thus reducing price volatility. The commenter states that the Potential Gas
Committee of the Colorado School of Mines releases a biennial assessment of the nation's natural gas
resources, and review from the 2006 assessment to the 2011 assessment indicates an increase in natural
gas total resource base from 1,321 to 1,898 trillion cubic feet (44 percent).

c.	According to the commenter, in addition to the natural gas available within the U.S., the natural gas
pipeline transmission systems of the U.S. and Canada are highly integrated, providing access to
Canada's vast gas reserves, which coupled with Canada's relatively small population, provides the U.S.
with an additional reliable source to help meet rising demand.

d.	The commenter states that according to the U.S. EIA Annual Energy Outlook 2011 projections,
production from shale formations in the U.S. grew by an average annual rate of 17 percent per year from

380


-------
2000 to 2006, and in the years from 2006 to 2010, U.S. shale gas production grew by an average annual
growth rate of 48 percent.

e.	According to the commenter, the natural gas industry has proven the ability to develop and distribute
natural gas required to meet increased demand from the EGU sector into the future.

f.	Commenter states that the EPA's analysis on fuel switching is flawed because it mistakenly presumes
retired generation must be replaced by building a gas-fired unit in the same footprint. According to the
commenter, with greater reliance on local resources, retiring coal-fired EGU capacity can be replaced by
natural gas-fired EGUs built closer to load, reducing dependence on interstate pipelines.

g.	The commenter states that historical trends also demonstrate that concerns over natural gas
availability and abundance are unfounded. The commenter states that according to the July

US EIA Natural Gas Monthly report, "nearly 237 GW of natural gas-fired power generation capacity
were added between 2000 and 2010, representing over three-fourths of total generation capacity
additions over that period." The commenter asserts that despite this growth in natural gas-fired
generation capacity additions, natural gas prices in 2010 remained relatively low and production rates of
natural gas continue to grow.

Commenter 17853 states that an immediate HAP benefit to the environment can be realized by
increasing utilization of existing and new natural gas-fired EGUs and cites the results of the Utility
Study and the preamble to the proposed rule as accurately depicting that the emissions of priority HAP
from natural gas-fired EGUs are negligible compared to coal. Commenter adds that natural gas-fired
EGUs also deliver significant emission reductions of PM, SO2, NOx, CO2, VOC, and regional haze
precursors.

Commenter 17853 points out that the EPA did not consider increased zero HAP emitting base-load
capacity as a fuel switching alternative. According to the commenter, since natural gas is not the only
source for power generation outside of coal combustion, the EPA could consider including a "fuel
neutral" fuel switching requirement which provides offsets for increasing zero HAP base-load
generation directly towards a corresponding decrease in coal-fired generation.

Response to Comments 25-27: The EPA declined to propose as a beyond the floor level of control a
requirement that coal- and oil-fired EGUs convert to natural gas. For existing sources, we indicated that
we did not believe the supply of and transmission infrastructure for natural gas were sufficient to convert
all existing units to natural gas. 76 FR 25046. We also determined that the incremental cost of electricity
(COE) for converting all existing coal- and oil-fired EGUs to natural gas would be between 4 and 22
times the costs of compliance with the MACT floor level of control. Id. For new EGUs, similar to that
for existing EGUs, we determined that natural gas was not available in all parts of the country. We also
concluded that we would decline to adopt a requirement that all new EGUs be natural gas-fired even if
we concluded that natural gas supplies were available because it would effectively prohibit construction
of new coal-fired EGUs and we did not believe that to be a reasonable approach to regulating HAP
emissions from EGUs. 76 FR 25049. We are not revising our decision in this final rule in response to the
comments and we address commenters' specific points below.

Commenters cite studies and reports that show that the supply of natural gas is growing, that the cost of
natural gas is generally stable, and that the availability of natural gas is expanding. One commenter even
notes that one study specifically considered such issues in the context of the proposed EGU NESHAP.
Even assuming all the studies are accurately characterized, the results do not in any way support a
determination that conversion of all coal- and oil-fired EGUs to natural gas is cost effective or that the

381


-------
supply and transmission capabilities are sufficient to support such a conversion. The commenters
maintain that the supply is currently sufficient and that the transmission capabilities are expanding, but
no commenter indicates that the current situation (or the situation within three years) would allow a
wholesale conversion to natural gas. The highest estimate provided by commenters is that one third of
the coal-fired generating capacity could be replaced. Even being able to replace one third of the coal
generating capacity with natural gas, this clearly falls short of the amount of fuel switching that would
be necessary to set a beyond the floor standard at levels that would require all existing coal units to
switch to natural gas. In addition, we continue to believe that a final rule that expressly prohibits new
coal construction is not reasonable. For all these reasons, we maintain that our proposed determination
not to require switching to natural gas as a beyond the floor level of control remains valid.

We also note that commenters appear to conflate the availability of natural gas as a cost effective
compliance alternative with the availability of natural gas as a beyond the floor requirement applicable
to all sources in a particular subcategory. We acknowledge that some sources will co-fire natural gas
with coal or oil as a compliance option and that other EGUs will be converted to burn 100 percent
natural gas. Both approaches are valid means to comply with the standards contained in the final rule;
however, the availability of these compliance alternatives does not support a determination that natural
gas conversion is available for all EGUs as a beyond the floor MACT standard.

The EPA did not presume as one commenter suggests that all new natural gas units must be located at
current EGU facilities, but when evaluating whether to establish a beyond the floor level of control for a
existing sources the agency does consider what the subject EGUs would have to do to comply with the
beyond the floor standard.

10.	Concurrence and caution for delegation of state programs.

Comment 28: Commenter 17810 recognizes the EPA's authority to delegate authority to implement
section 112 rules and regulations in section 112(1) to states, provided that the state program is "no less
stringent" than the federal program with respect to quantity of emissions, rule applicability, and level of
control. Commenter has supported such state programs, including the Colorado Clean Air-Clean Jobs
Act, and concurs with the EPA that these type of programs will ultimately result in significant emission
reductions from coal-fired EGUs, as companies implement strategies (e.g., retirement/replacement with
natural gas or other "cleaner" generation) and/or technologies (e.g., state-of-the-art controls) to meet the
requirements. Commenter cautions that they expect that the EPA should look very closely at state
programs or rules that have compliance dates beyond those contained in the federal rule to ensure that
these programs merit greater reductions in HAP emissions beyond the federal rule to justify the
extended compliance deadline.

Response to Comment 28: Response to this comment may be found in the preamble to the final rule.

11.	Concerns from non-continental EGU sources.

Comment 29: Commenter 18477 expresses concern that the proposed rule mistakenly assumes that
switching to natural gas or co-firing with natural gas is a valid and cost-effective compliance option for
liquid oil-fired units; however, there is no natural gas or liquid natural gas resource in Hawaii. The
commenter states that as a remote island utility, it does not even have access to the small amount of
refinery gas available to the refiners addressed by the Boiler MACT.

Commenter 18477 states that all oil-fired EGUs operating in Hawaii, Guam, and Puerto Rico
exclusively combust residual fuel oil to generate electricity, and all are limited by the crude slates of

382


-------
their fuel suppliers. The commenter states that its contracts with on-island refineries contain fuel
specifications for factors such as sulfur content, pour point, flash point, API gravity and viscosity, which
the refiners are able to meet primarily by blending and some sulfur removal. However, they do not and
cannot economically control for metal content. The commenter states that as the agency noted in the
preamble to the Boiler MACT, the quality of the fuel produced by non-continental refineries is limited
by the quality of the crude slate used in the refining process (76 FR 15,635).

Commenter 18477 states that it is not feasible for non-continental liquid oil-fired EGUs to comply with
the proposed numeric emission standards based on their survey of equipment control vendors. The
commenter states that the vendors surveyed uniformly responded that they cannot guarantee their
equipment can meet the proposed HAP limits for liquid oil-fired EGUs. The commenter states that the
ability to achieve HAP control with residual fuel oil applications and ESPs or multi-cyclones in utility
type boilers is currently being researched and is not a commercially demonstrated technology.

According to the commenter, bag-houses are not a suitable technology for particulate matter control for
residual fuel oil applications. The commenter states that reputable dry and wet ESP suppliers, such as
Alstom, Babcock & Wilcox, PECO, Siemens, Southern Environmental Inc., Clyde Bergemann, Hamon
Research-Cottrell, and Allied Environmental Solutions, Inc. were contacted to determine their current
position on providing ESP guarantees to meet the proposed emission limits for liquid oil-fired units, and
the companies that have provided feedback thus far will not guarantee that currently available
technology can achieve the proposed emissions limits for residual fuel oil applications. Commenter
included Attachment C as a summary of the vendor responses in the Docket No. The EPA-HQ-OAR-
2009-0234.

Comment 30: Commenter 18502 states that because they are a non-continental facility, the availability
of alternate fuels is limited. The commenter states that there are no fossil fuel resources on the island
(Puerto Rico) and that the fuels presently used are delivered by ocean tankers, which is a
possible source chloride contamination of the fuel as indicated by the erratic HCI measurements made
during the ICR testing (HCI emissions varied by a factor of 20).

Commenter 18502 states that it has a long term plan for converting their steam generators, CCs, and
CTs to co-fire natural gas (NG), but the infrastructure needed to deliver natural gas does not currently
exist. The commenter states that the long term plan involves participation in expansion of a local LNG
facility operated by EcoEiectrica and actively pursuing installation of a NG pipeline. The commenter
states that engineering evaluations and permitting for the pipeline is underway, but completion has not
been established yet.

Response to Comments 29 - 30: As noted elsewhere in this document, the EPA is establishing a non-
continental liquid oil-fired subcategory in the final rule.

383


-------
5C04 - Compliance: Switching subcategories

Commenters: 17402, 17621, 17638, 17681, 17736, 17754, 17772, 17781, 17790, 17796, 17800, 17868,
17881, 17902, 18014, 18018, 18444, 18449, 18498, 18502, 19033

1. Performance testing.

Comment 1: Commenter 17402 requests that the EPA allow facilities to set the capacity level at which
a plant operates during a performance test. The commenter stated the EPA in allowing this will be
providing another option for compliance, particularly as facilities transition and install new control
equipment. According to the commenter, this approach will not cause an increase in emissions given
that the facility would be limited in its ability to exceed the capacity level at which it is operating during
the test.

Response to Comment 1: Pursuant to section 63.10007(c), performance tests are to be conducted under
normal operating conditions. Unlike the proposed rule, there is no operating limit established in terms of
110% of the capacity level used during the most recent performance test.

Comment 2: Commenter 17754 states that the proposed rule should be revised to clarify that an affected
source may elect to perform and/or rely on performance testing for the PM surrogate as the basis for
initial and continuous compliance with total non-Hg HAP metals emission limit.

Commenter 17754 states that the EPA should not require an owner/operator of an affected EGU who
elects to demonstrate compliance with total non-Hg HAP metals using the PM surrogate to conduct
performance testing for both PM and total non-Hg HAP simultaneously. According to the commenter,
the EPA should revise the rule to allow that if an owner/operator elects to comply by using the PM
surrogate, the owner/operator is not required to conduct performance tests for both PM and total non-Hg
HAP. The commenter states that the rule should be revised to provide that if a facility elects to conduct
simultaneous performance testing of the PM surrogate and total non-Hg HAP metals, and as a result
demonstrates compliance with one of the limits while exceeding the other, the affected EGU shall be
deemed to be in compliance.

Commenter 17781 states it is inappropriate to require units relying on a surrogate to also conduct
performance testing for the associated surrogate pollutant(s). According to the commenter, this approach
is inconsistent with other 40 CFR part 63 standards which allow use of surrogates. The commenter states
that the EPA has provided no rationale for the collection of this additional data.

Response to Comment 2: In response to comments, the final rule has removed all requirements for
duplicative testing of a HAP and a surrogate pollutant. Facilities complying with a surrogate standard
will conduct the performance test for that standard, and not for the corresponding HAP (and vice versa).

Comment 3: Commenter 17796 objects to the initial performance test requirement for all source owners
and proposes that once the initial performance test is conducted for PM and non-HAP metals, fuel
sampling will be adequate to demonstrate compliance in lieu of stack testing. According to the
commenter, stack testing should be no more frequent than every 6 months.

Response to Comment 3: The final rule does not contain the proposed fuel sampling and analysis
compliance demonstration approaches. See the final preamble and discussion under Comment Code 5A.
The final rule uses either CEMS, where applicable, quarterly performance testing, reduced testing under

384


-------
the LEE provisions, or annual testing with a PM CPMS for the filterable PM or non-Hg HAP metals
limits that apply.

Comment 4: Commenter 17881 states this requirement creates confusion in regards to the actual
compliance mechanism. The commenter asks that if a unit complying with the PM emission limit
surrogate for non-Hg HAP metals conducts performance testing for both PM and multiple metals, what
would happen if one or more of the individual metals were above the standard (or, although unlikely,
total non-Hg metals are shown to be above the standard)?

Response to Comment 4: In response to comments, the final rule has removed all requirements for
duplicative testing of a HAP and a surrogate pollutant. Facilities complying with a surrogate standard
will conduct the performance test for that standard, and not for the corresponding HAP (and vice versa).

2. Test methods and methodology.

Comment 5: Commenter 17621 provided discussion of testing methods recommended for ICR data
collection and compliance with proposed MACT limits.

a.	Method 3OB: Commenter 17621 states that Method 3OB does not specify a MDL or require that one
be determined. The commenter states that a tester must estimate in advance the minimum sample
volume that will provide adequate mass of Hg for analysis for the specific source and analytical
technique. This commenter states it is possible to state a minimum mass of Hg that must be collected on
a sorbent tube to obtain an accurate measurement by a given analytical method. The commenter states
that based on EPRI's reviews of many ICR Part III test reports, almost all samples were analyzed using
thermal desorption/CVAAS. According to the commenter, this research indicates at least 10 nanograms
should be collected on the front bed of the sorbent tube to ensure accurate results. According to the
commenter, there are two reasons for this: 1) to minimize inaccuracy due to instrumental gas flow
fluctuations that can distort the desorption peak shape, and 2) to raise the sample mass sufficiently above
the background sorbent mercury level. The commenter states that test runs with loadings below 10
nanograms generally failed method quality criteria for one or more of the three samples.

Commenter 17621 states that EPRI has classified the adequacy of Method 30B to measure at the
proposed MACT limit for new coal EGUs as uncertain based on reports from several stack testers that at
high sample flow rates leakage and equipment failure has occurred.

Commenter 17621 believes it is uncertain whether Method 30B can, for liquid oil-fired EGUs, measure
Hg accurately at the proposed MACT limit for existing EGUs, and will be unable to measure Hg for
new units without excessively long (about 30 hours) test runs.

b.	Method 5: Commenter 17621 states that it is not certain whether Method 5 sensitivity is adequate to
support compliance monitoring at the MACT limits for total PM, as that will depend upon the relative
proportions of filterable PM and condensable PM in the stack gas. According to the commenter, for a
stack gas where PM emissions are predominantly filterable PM, the above methods will be able to
measure accurately at the proposed total PM limit (0.03 lb/MMBtu) for existing coal-fired EGUs. The
commenter states that at the proposed limit for new EGUs (0.05 lb/MWh, approximately 0.005
lb/MMBtu), Method 5 should still be sufficient to measure accurately by gravimetric analysis and
whether the overall method accuracy, considering sampling variability, will be adequate at that emission
rate is unknown. Commenter adds that field studies conducted by EPRI and others have identified
problems with the accuracy of Method 5 at low emission levels. According to the commenter, results

385


-------
can be biased high or low depending on how the sample is collected. The commenter states that a recent
study conducted by AEP and EPRI found that the material used for the particulate filter (glass fiber
versus quartz fiber filter) can produce a significant bias in the results due to acid gas sorption on the
alkaline material of glass fiber filters (EPRI, 2011). According to the commenter, the temperature of the
sampling probe and filter also affects the amount of filterable PM collected, with the lower temperature
collecting more filterable PM. The commenter states that the ICR Part III data include tests conducted at
two different temperatures (250 °F and 320 °F) and with both types of filters, and that these variables
introduce additional uncertainty into conclusions drawn from the ICR data, in addition to normal method
variability.

c.	Method 202: Commenter 17621 states that it is not certain whether the Method 202 sensitivity is
adequate to support compliance monitoring at the proposed MACT limits for total PM, as that will
depend on the relative proportions of filterable PM and condensable PM in the stack gas. According to
the commenter, for a stack gas where the PM emissions are predominantly condensable PM, the mass
collected in a 4-hour test will be sufficient for an accurate gravimetric measurement at the proposed total
PM limit (0.03 lb/MMBtu) for existing coal units. The commenter states that at the proposed limit for
new EGUs, approximately 0.005 lb/MMBtu, the collected PM residue is also sufficient to measure
accurately by gravimetric analysis, but limited results of field testing indicate that the overall method
accuracy may not be adequate at that emission rate. Commenter adds that a field study conducted by
AEP at several coal-fired power plants found that revised Method 202 has high between-run variability
(EPRI, 2011). The commenter states that in four replicate tests conducted with the same sampling
conditions (probe temperature, PM filter type, and sampling duration), the relative percent difference
(RPD) of the CPM measurements ranged from 25-78 percent. The commenter states that these were
samples taken at different times and were not parallel train samples; however, process monitoring
indicated that there were no upsets during the sampling periods. The commenter states that filterable PM
samples taken from the same sampling trains had lower (6-27 percent) variability. Condensable

PM emissions in the samples ranged from 0.0032 lb/MMBtu to 0.013 lb/MMBtu. The RPD of the
replicates at the lowest emission rate, about twice the proposed MACT total PM limit for new plants,
was 78 percent. According to the commenter, these findings indicate that the method does not provide
sufficient precision to support compliance monitoring at the proposed limit for new coal-fired EGUs and
may not provide sufficient precision at the proposed limit for existing coal-fired EGUs. Commenter also
adds that an EPRI laboratory study of OTM-28 determined that modifications from the original Method
202 had reduced the positive bias due to aqueous-phase conversion of gaseous SO2 to sulfuric acid
(a condensable PM species) compared to original Method 202 (EPRI, 2009). The commenter states that
the study also found that OTM-28 did not appear to capture sulfuric acid aerosol effectively. According
to the commenter, as sulfuric acid is the predominant condensable PM species in coal-fired power
plants, this finding may indicate that the revised Method 202 has a negative bias.

d.	Methods 5 and 202: Commenter 17621 states that the combination of Methods 5 and 202 is sensitive
enough to provide accurate gravimetric measurement at the proposed MACT limits for both existing and
new coal-fired EGUs. According to the commenter, the precision of Method 202 may not be sufficient at
the new EGU limit to support that determination.

Response to Comment 5: The EPA does not agree that all components of a test method composed of
composite analyses need to be above the minimum detection limit to provide reliably accurate
quantification of the total emissions. While the commenter focuses on the four components used to
quantify total particulate matter, other test methods and pollutants would present similar influences.
While it is common to collect less than a measureable mass in the nozzle and probe portion of
particulate sampling trains, this has an insignificant impact on the filterable or the total particulate matter

386


-------
measurements when the quantity of material collected on the other components are above the levels
which minimize measurement precision. In the test data from the mix of PM tests performed under the
Part III ICR, there were few individual runs where the mass of particulate was below the mass that has
routinely been determined to be the minimum detectable mass for the different components. For
filterable particulate, only 51 test runs out of 1252 had less than 1.3 mg of particulate on the filter and
probe wash. For inorganic condensable particulate, only 19 of the 772 runs reported a mass of less than
1.5 mg. Last, for organic condensable particulate, 30 test runs out of the 772 runs reported a mass of less
than 0.5 mg. These weights are the approximate detection levels for these components of total
particulate. There were no sources where the mass for all components were less than these levels.
Therefore we would not expect that any source would be challenged to demonstrate that their emissions
were less than the proposed total particulate level we proposed. Since we have selected filterable
particulate as the alternate equivalent standard for non-Hg metals, there are only two measured
components and the filter component is expected to have the majority of the PM. In reviewing the
filterable PM data, a 4-hour source test with 5 mg particulate on the filter (the approximate mass above
which Method 5 has a consistent precision) would have emissions of approximately 0.0014 lb/MMBtu.
This emissions level is much lower than the filterable PM emissions limit we have established in this
rule. As a result, we do not expect any sources to have problems in accurately quantifying their
emissions either when they are near the emissions limit or near the LEE emissions level. We agree with
the commenter concerning the influences on filter selection and filtration temperature on the
determination of mass on the filter. Sources and source test contractors will be advised to insure that the
filter media they use meets the requirements of Method 5 with respect to the reactivity to acid gases to
insure that their measurements are not biased. A similar bias may arise as a result of maintaining the
wrong filter temperature.

Comment 6: Commenter 17881 states the use of PM filterable will simplify the associated testing
requirements in that a single Method 5/Method 29 sampling train could be used to simultaneously test
for both the PM surrogate and multiple metals. According to the commenter, use of a PM filterable
surrogate would also allow a direct compliance determination via the use of PM CEMS (which are only
capable of measuring PM filterable emissions).

Response to Comment 6: In response to comments, the final rule has removed all requirements for
duplicative testing of a HAP and its surrogate. Facilities complying with a surrogate limit do not have to
perform periodic testing for the corresponding HAP. We agree with the commenter in that Method 29
provides the ability to concurrently quantify filterable PM and the non-Hg metals which we are
regulating. The final rule uses a PM CPMS approach. See the final preamble and Comment Code 5A07a
for further discussion.

Comment 7: Commenter 18444 states that the particulate filterable temperature is defined as 320 °F ±
25 °F, which is the temperature currently used for non-sulfate filterable PM testing, and this appears to
be because the sulfate is to be counted with the condensables. According to the commenter, this is
different than most of the EPA testing (248 °F ± 25 °F), so the filterable particulate results measured
under these new requirements would likely be lower than what would be currently measured. The
commenter states that since the limits are for the total PM (filterable and condensable) the total catch
should in theory be the same regardless, but this would impact the PM CEMS (if used) since they will be
measured on the filterable only. The commenter states that companies would have to test separately for
compliance with different federal particulate limits based on these temperature differences, adding to the
testing workload.

387


-------
Commenter 18444 states the filter temperature for metals testing is defined the same as for particulates
(320 °F+ 25 °F) instead of the current practice (248 °F + 25 °F). The commenter states that the proposed
rules mention determining filterable metals separately from total metals, and as with PM, this impacts
limits set for Hg CEMS or sorbent monitoring (if used) since particulate Hg is not measured by these
methods. According to the commenter, in this case, there will be higher mercury results on the
CEMS or sorbent monitoring since the higher filter temperature would allow more Hg to pass through
the filter. The commenter states that as long as the EPA adopts stringent PM limits, that particulate Hg
emissions will not be significant; monitoring gaseous Hg should be sufficient and the filter temperature
should not change the gaseous Hg results significantly.

Response to Comment 7: While we deliberated what filter temperature should be used in the collection
of test data with Method 5, Method 29, and Method 26A, we selected 320 °F for multiple reasons. First,
it is consistent with the temperature used for compliance with existing rules. As a result this allowed a
mare direct comparison with that data and provided us with an understanding of the within source
variability of emissions. It also provided a more direct ability to establish a particulate level for
correlation or alternative applications of PM CEMS. The absence of SO3 on the filter and the collection
in the impinger provides for more consistency in obtaining constant weights. Since little or no SO3 is
retained on the filter, the highly hydroscopic SO3 does not cause weighing difficulties by absorbing
water from the air. Also, by moving the SO3 to the impinger, the SO3 can be neutralized and thereby
making it easier to achieve constant weight. Lastly, it provided a partitioning of the components of
particulate similar to the majority of the existing emissions controls.

Comment 8: Commenter 19033 states that the proposed regulation section 63.10005(b) specifies that
performance tests are to be conducted; as specified in Table 5. With respect to the proposed PM
limit, the commenter notes that the testing requirements are Method 5 and 202, with the specific
provision that tests using Method 5 must be performed at a filter temperature of 320° F. However, some
state permit conditions require that filterable PM, as measured by Method 5, be conducted at a filter
temperature of 250 °F. Commenter adds that filterable PM measured by Method 5 at 250 °F is expected
to provide different (and higher) results than filterable PM measured by Method 5 at 320 °F, because of
the condensation of sulfuric acid at 250 °F. According to the commenter, consequently, a mechanism is
needed to allow EGUs required to perform Method 5 tests at 250 °F to concurrently demonstrate
compliance with the proposed PM limit based on a Method 5 filter temperature of 320 °F. Commenter
19033 suggests the following mechanism to accomplish the concurrent compliance demonstration:

1.	Perform all required PS-11 PM CEMS correlation curve testing using EPA Method 5 at a filter
temperature of 250 °F, if the state agency so directs.

2.	Perform PM compliance tests with respect to the proposed limit at a filter temperature of 320 °F.
According to the commenter, if compliance is demonstrated, the concurrent PM CEMS output
(which will be biased high, because it will correlate to 250 °F) will become the filterable
concentration limits, rather than the three-run filterable PM concentration limit measured at 320 °F.

Commenter 19033 recommends revisions in Tables 4 and 7, in order to implement the above described
mechanism. In conjunction with the changes recommended for Tables 4 and 7, Commenter 19033
also recommends that proposed regulation 63.10011 (d) be amended as follows:

... You must determine an operating-limit (PM concentration in mg/dscm) during
performance testing for initial PM compliance. The operating limit will be the average of
the PM filterable results of the three Method 5 performance test results, unless the state
agency requires the Method 5 tests to be performed at a filter temperature of250°F. If

388


-------
the Method 5 tests are required to be conducted at 250°F, the operating limit will be the
average of the PMfilterable results reported by the PM-CEMS rather than the PM
filterable results of the three Method 5 tests performed at 320°F, provided compliance
is demonstrated by the Method 5 tests conducted at 320°F.

Comment 9: Two commenters (18444, 19033) express concern over the EPA requirement that the stack
test filter temperature is set at 320 °F when other regulatory authorities and/or State agencies may
require a different lower temperature of 250 °F.

Response to Comments 8-9: The final rule has been revised to remove the requirements for Method
202 and PS-11, so those comments are moot. The 320°F filtration temperature was chosen for the
determination of compliance with the standard due to match the data collection temperature. If sources
would like to harmonize their testing requirements with other limits at lower filtration temperatures, they
may request to do so per 63.7. The EPA agrees that there are biases associated with improper selection
of filter material. Method 5 states that sources with S02 or S03 should select an unreactive filter to
handle such issues. The EPA disagrees that Method 30B cannot measure the levels specified in the
emission standards. The data used for the new source MACT limit were based on Method 30B 4 hour
test runs that met all QA criteria with a catch under 10 nanograms. The EPA disagrees that we should set
a specific ng catch for the method, but welcomes sources to devise test plans with those DQOs.

3. Test methods unreliable or inadequate.

Comment 10: Commenter 17736 states that including condensable PM raises concerns about the
efficacy of monitoring technologies used to determine compliance. According to the commenter,
measuring condensables separate from filterable PM is new and is not widely accepted by the industry
due to a lack of data supporting the method's accuracy.

Response to Comment 10: As we state elsewhere, we evaluated the ability of all particulate
components to be a surrogate indicator of non-Hg metals emissions. As a result of that evaluation, we
have selected filterable particulate since it offers several advantages with respect to continuous
monitoring and ease of demonstrating compliance. The comments regarding a supposed lack of
condensable PM data and potentially inaccurate condensable PM test method are moot, not because we
agree with either supposition but because the rule no longer contains a total PM emissions limit. With
respect to accuracy, particulate matter is a pollutant that is sensitive to the method which it is collected.
This includes not only how much material is in solid or liquid form but also the size distribution of the
particulate matter. By establishing a truly standard collection hardware, conditions for the separation of
the water and sample gas, temperature for collection and analytical finish we have also established the
material which is retained and measured as PM.

Comment 11: Commenter 17881 states as currently written, section 63.10006(e) requires that the fuel
factor methodology and equations in sections 12.2 and 12.3 of Reference Method 19 (40 CFR 60,
Appendix A-7) be used to convert the results of the performance tests into units of lb/MMBtu of
lb/TBtu, as applicable. This section should recognize that such calculations need not be conducted if
an EGU has chosen to demonstrate compliance with the mass per unit of electrical output emission
limits. The EPA should also allow the use of fuel factors determined in accordance with sections 3.3.5
and 3.3.6 of 40 CFR Part 75, Appendix F. Of particular concern is the fact that Reference Method 19
does not contain fuel factors for subbituminous coals, solid oil (i.e., petroleum coke) or tire-derived-fuel,
any of which could be fired in solid fuel-fired boilers subject to the proposed rule.

389


-------
Response to Comment 11: The EPA agrees, and has made corresponding changes to section
63.10007(c) in the final rule.

Comment 12: Commenter 18449 expressed the concern that, if the +1 |ig/m3 alternate specification is
tightened, an increased frequency of testing errors will cause even CEMS that are operating properly to
fail. According to the commenter, the EPA should consider a mandatory periodic QA/QC program
where it or another impartial agency loads sorbent traps supplied by the test group with the output from
a NIST traceable elemental calibrator. The commenter states that this approach should be applied to both
RATA testers and to suppliers of continuous sorbent testing services.

Response to Comments 12: The comment is moot because the final rule did not tighten the alternative
specification.

4.	Surrogates.

Comment 13: Commenter 17736 states that the EPA's proposed rule creates a double standard,
facilitating potentially inconsistent enforcement practices. The commenter states that non-Hg HAP
metals compliance provisions should be written to provide a unit electing to comply with a surrogate
with continuing compliance demonstrated not to be deemed in non-compliance for exceeding an
emission limit during a stack test.

Response to Comment 13: In response to comments, the final rule has removed all requirements for
duplicative testing of a HAP and its surrogate. Facilities complying with a surrogate limit do not have to
perform periodic testing for the corresponding HAP, and vice versa.

Comment 14: Commenter 17881 states Table 4 of the proposed rule, as well as section 63.10005(d)(4),
indicate use of the SO2 surrogate is predicated on the EGU both being equipped with wet or dry FGD
and using an S02 CEMS for the compliance determination but that section 63.10006(h) applies to those
solid oil-fired and coal-fired EGUs without SO2 CEMS but with wet or dry FGD controls. The
commenter states that such EGUs are required to conduct S02 and HC1 testing during the same
compliance test period and under the same process (i.e., fuel) and control device operating conditions at
least every year, as well as conduct S02 testing at least every other month. The commenter states that
this paragraph is confusing, as SO2 is being treated as a regulated pollutant even though its use as a
surrogate would appear to be barred in the absence of an SO2 CEMS. According to the commenter, it is
very unlikely that there are any solid oil-fired or coal-fired EGUs of sufficient size to be regulated under
the proposed EGU MACT but not be equipped with SO2 CEMS, as such CEMS are generally required
by one or more of the following: 40 CFR Part 60, 40 CFR Part 75, and State Implementation Plans.

Response to Comment 14: In response to comments, the final rule has removed all requirements for
duplicative testing of a HAP and its surrogate. Facilities complying with a surrogate standard will
conduct the performance test for that standard, and not for the corresponding HAP (and vice versa). The
specific provisions cited in this comment have been clarified in the final rule such that only the HC1
testing would be required under such circumstances.

5.	Test requirements.

Comment 15: Commenter 17772 submits that the testing requirements are excessive and unnecessarily
redundant. According to the commenter, for units that do not use a PM CEMS, the proposed rule would

390


-------
require testing every other month, which is unjustified and costly. This commenter also states it is
unclear how compliance is determined under the multiple testing scenario.

Comment 16: Commenter 17796 supports testing for filterable particulates as well as condensable PM.

Comment 17: Commenters 17638 and 17681 state that the EPA should not require HAP stack testing
for EGUs using a surrogate, and should remove the requirement that EGUs using PM as a surrogate for
non-Hg HAP metals conduct a stack test for non-Hg HAP metals. EGUs using SO2 as a surrogate for
HC1 should not be required to stack test for HC1. Commenters also state that the EPA should not require
stack testing of surrogates when a source chooses to comply with the HAP limit.

Commenter 17790 submits there is no justification for testing for the HC1 surrogate (Method 502) if a
company is complying with the HC1 standard.

Commenter 17868 states that the EPA has no basis to require HAP stack testing for EGUs using
surrogates or to require surrogate testing for EGUs not relying on surrogates. The commenter states that
the requirements are duplicative and should be removed.

Commenter 17881 states it is inappropriate to require units relying on a surrogate to also conduct time
consuming and costly performance testing for the associated surrogate pollutant(s). According to the
commenter, this approach is wholly inconsistent with other 40 CFR Part 63 standards which allow the
use of surrogates, and the EPA has provided no rationale for the need to collect this additional data. The
commenter states that if the EPA is concerned about the relationship between the chosen surrogates and
their associated HAP(s), then the EPA should initiate an additional ICR effort which will allow them to
further study the relationships between HAP(s) and their potential surrogates.

Commenter 17881 states that the provisions of section 63.10006(i) are very similar to those in section
63.10006(d) in that they require testing of both the surrogate (i.e., S02) and the associated HAP
(i.e., HC1) even though the surrogate cannot be relied upon for compliance for solid oil-fired and coal-
fired EGUs without a SO2 CEMS and without wet or dry FGD controls.

Commenter 18498 states that the requirement to stack test for both the pollutant and surrogate is
redundant, and requests the EPA to remove the requirement that both the pollutant and surrogate be
stack tested. According to the commenter, a performance test should only be required for the pollutants
and surrogates with which a source is choosing to show compliance.

Multiple commenters (17638, 17681, 17754, 17772, 17781, 17790, 17800, 17881) express the concern
that requiring testing for both a pollutant and its surrogate is unnecessary when only one should be
adequate for demonstrating compliance.

Commenter 17800 states that requiring sources to test either for the actual HAP in cases where
surrogates are being used for compliance is duplicative, has no rational to be required, and will increase
the cost of compliance.

Commenter 17881 states that the provisions of section 63.10006(d) require that petroleum coke and
coal-fired EGUs without PM CEMS (but with PM control devices) conduct all applicable tests for PM
and non-Hg HAP metals testing during the same compliance test period and under the same process
(i.e., fuel) and control device operating conditions at least every year, as well as conduct non-Hg HAP
metals testing at least every other month. The commenter states that the PM surrogate only applies to

391


-------
those units equipped with a PM CEMS, so it makes no sense that such units are required to conduct
concurrent PM and non-Hg HAP metals testing, as PM is not a regulated pollutant for such units. The
commenter states that as discussed in relation to 63.10005(a), the EPA should conduct an
additional ICR if they feel it is necessary to collect additional data on the relationship between PM and
non-Hg HAP metals emissions.

Response to Comment 15-17: We agree that a reduction in the frequency and types of measurements
and monitoring that we proposed is appropriate and will still provide an assurance that sources are
maintaining reasonable emissions control of HAP metals and acid gases. First, in response to comments,
the final rule has removed all requirements for duplicative testing of a HAP and its surrogate. Facilities
complying with a surrogate limit do not have to perform periodic testing for the corresponding HAP,
and vice versa. Second, we have changed all requirements for periodic monthly or every other month
performance testing to quarterly, with an exception for quarters with very low operating hours. We have
clarified that no performance stack testing is required where a CEMS is used for direct compliance, and
we have also established an annual performance test requirement for sources that elect to use a PM
CPMS as part of the continuous monitoring approach for ensuring compliance with a filterable PM or
HAP metals emission limit.

Comment 18: Commenters 18014 and 18498 state that the minimum sampling time of four hours
required by section 63.7520(d) for compliance tests is excessive. According to the commenters, the EPA
should re-evaluate the required sampling times for each method and/or provide alternative minimum
volumes for each method.

Response to Comment 18: We have selected the appropriate test duration that we believe is required to
achieve the necessary measurement precision needed to determine compliance. Source testing
companies are encouraged to perform an assessment of the ability of an alternative sampling duration,
sampling rate and analytical finish which provides for comparable reliable, precise and accurate
measurements and that is representative of the sources operation.

Comment 19: Commenter 18018 states that the EPA's proposed compliance requirements are overly
burdensome and should be modified due to certain compliance requirements for the proposed air toxic
rule that may result in periods of noncompliance by some EGUs that may be capable of complying with
the emission limits under normal operations. According to the commenters, the following change would
facilitate compliance with the proposed rule: PM compliance testing should involve only filterable
particulates. Including soluble particulates will complicate compliance testing without providing
significant additional compliance assurance.

Response to Comment 19: The final rule uses filterable PM as the surrogate for non-Hg HAP metals.
See further discussion of this issue in the preamble and elsewhere in this document.

5. Other.

Comment 20: Commenter 17902 states the proposed rule definition for a unit designed to burn solid-oil
derived fuel and its application is unclear for units that co-fire pet-coke and coal together. The
commenter states that the application of Table 1 and Table 2 emission limits needs to be clarified
including how emission limits will apply for units that move from one subcategory to another.

According to the commenter, the relevant MACT emission limits should be applied based on the
majority of fuel actually combusted annually on a heat input basis.

392


-------
Response to Comment 20: According to the definitions of coal-fired electric utility steam generating
unit and oil-fired electric utility steam generating unit in §63.10042, should an EGU that co-fires pet
coke and coal such that more than 10 percent of the annual heat input for 3 years or 15 percent of the
annual heat input for one year is from coal, the EGU is a coal-fired electric utility and would be subject
to the coal-fired emissions limits.

Comment 21: Commenter 18502 expressed concern that natural sources of atmospheric chlorine in
coastal areas that a facility cannot control can cause wide variations in emission rates. The commenter
states that these include chloromethane formed by action of sunlight on marine biomass and chlorine
from sea foam, possibly influenced by wind direction.

Response to Comment 21: The rule has been revised to address this concern for liquid oil-fired EGUs,
such that an owner or operator need not conduct HC1 or HF emissions measurement if the owner or
operator conducts fuel moisture analysis or provides certification from a fuel supplier and that analysis
or certification shows fuel moisture content does not exceed 1 percent.

393


-------
5C05 - Compliance: Treatment of Common Stacks
Commenters: 15678, 17733, 17739, 17775, 17781, 17796

1.	Unit-by-unit control.

Comment 1: Commenter 15678 supports the EPA's application of emission standards to each operating
EGU instead of to the overall site consisting of several EGUs. This commenter stated that this approach
is especially important for areas with large amounts of impervious land cover where increased
stormwater runoff will contribute more land deposited Hg to the food chain via bioaccumulation in
seafood. The commenter strongly supports applying the MACT standard to all EGUs.

Response to Comment 1: We have responded to comments relating to emissions averaging across
EGUs at a common site in a given subcategory elsewhere in this document.

Comment 2: Commenter 17733 states that in order for the EPA to meet its responsibilities under the
Trust Responsibility and the Environmental Justice Doctrine, the EPA should apply the most stringent
applicable standard under the EGU MACT Rule to all IB units in a contiguous area and under common
control. The commenter states that this approach is necessary to be consistent with the rule's description
of a source and helps insure the rule can take advantage of economies of scale by having all IB units at a
source apply the same level of control technology. According to the commenter, this approach prevents
IB unit owners from avoiding stringent EGU MACT rule requirements by dismantling shared pollution
control device exhaust stacks. The commenter states that the EPA should require all IB units as a source
to meet the most stringent EGU MACT standard applicable to any EGU at a source.

Response to Comment 2: To the extent commenter is referring to industrial boilers, those comments
are outside the scope of this rulemaking and are not addressed. To the extent commenter is referring to
EGUs, we have addressed comments related to emissions averaging across EGUs at a common site in a
given subcategory and to common stacks elsewhere in this document.

2.	Use of combined stack data.

Comment 3: Commenter 17739 states that the EPA's use of combined stack data is inconsistent with its
treatment of data below the MDL. The commenter states that in the Boiler MACT, the EPA concluded it
was inappropriate to use values below the MDL for the simple and correct reason that "such values have
not been demonstrated to have been met" (76 FR 15624) and that the same is true with respect to data
from combined stacks; no unit actually "met" the reported value, let alone two. According to the
commenter, the data point of the combined emissions is a fiction that represents the combined
performance of the suite of control trains and boilers, and there is no basis to know whether one unit
would measure higher and the other lower if tested separately, rather than assuming they would both
measure exactly the same. The commenter states that in fact, the one result of which we can be
absolutely sure is that both units would not produce identical emissions. The commenter states that the
EPA's creation of multiple data points from a single combined stack data point are simply a fiction that
is not permissible under the MACT standard setting criteria.

Comment 4: Several commenters (12991, 17739, 18023) disagree with the EPA's use of data from
multiple units exhausting through a common stack. Commenter 17739 states that the EPA makes two
errors: 1) EPA unreasonably treats data from multiple units exhausting through a single stack as multiple
data points, and 2) EPA applies this incorrect approach inconsistently. While it may be acceptable for

394


-------
the EPA to surmise that the combined performance of multiple boilers and pollution control devices
represents an emissions control strategy that could be a best performer, thereby entitling the agency to
use the data at all, the fact is there is only one performer not two. Apart from being inconsistent with
applicable MACT case law, commenters assert that counting combined stack emissions as two or more
data points is unreasonable because it dampens variability and over represents the emissions data by
creating multiple "performers" or sources when there is in fact only one. In the Boiler MACT, the EPA
argues its approach of creating two data points from a single combined stack data point is reasonable
because it cannot separate the commingled fraction of the emissions from the different emission points.
Commenters state that is irrelevant and there is no basis to separate these emissions because the MACT
floor is based on best performing sources and there is only a single source. Indeed, the opposite is true.
Commenters state that the EPA cannot determine what amount of the overall performance of a
combined stack data point is the specific result of the combination. The EPA also argues that applying
the emissions equally to multiple units exhausting through a single stack "accurately represents the
emissions of those units on average. Commenters assert that is simply not correct and there is no
plausible factual basis for that statement. There is no unit that "achieved" those emissions. Rather, the
data represent the combined weighted average of two units, without knowing how either unit actually
performed.

Commenter states that in the Boiler MACT, the EPA asserts that adding multiple data points for
common stack units provided additional data where the EPA's databases are sparsely populated.
Commenter states that counting a single stack unit twice to have more data is not necessary in the utility
MACT, which is not lacking for data. Commenter also states that counting as two a single stack may
dampen variability unlike the EPA's claim in the Boiler MACT. Commenter states that the practice of
treating plants that have multiple boilers exhausting through a single stack as if they were separate
sources is fairly systemic and results in a widespread population of the database with fictional values.

Commenter 12991 disagrees with the use by the EPA of duplicate records for determining the Hg
MACT floor. The commenter states that in several instances when a facility operated tandem or multiple
units but only submitted a single stack measurement, the EPA used the single stack measurement to
represent Hg emissions from the facility's other stacks. According to the commenter these duplicate
records should not have been used because the agency did not systematically select the units; that is, the
selection of units was not entirely random nor was it purposefully intended to identify the best-
performing units within the total population of units. According to the commenter, the EPA did
randomly select some units while intentionally selecting some of the best performing units resulting in a
biased selection represented by a greater percentage of baghouse-controlled units than exists in the
population of coal-fired utility sources. The commenter states that the duplicate records are redundant
and should not be included because they cannot be considered to represent the best performing sources
or to be an unbiased or random sample.

Commenter 18023 states that the EPA's MACT floor database lists the four units at Georgia Power
Company's Plant Hammond as four separate sources. These units, however, share a common FGD and a
common stack. It would be impossible to differentiate the emissions resulting from each unit. This error
is not limited to Georgia Power Company's Plant Hammond. This error occurs in 19 of the 130 lowest
emitting units for Hg, 25 of the lowest emitting units for PM, and 19 of the lowest emitting units for
HC1. The EPA should treat the emission value from units with a common stack as a single source in the
MACT floor calculation. Furthermore, the EPA must be consistent in how it treats units with a common
stack. Contrary to the manner in which the EPA analyzed Plant Hammond, the EPA has considered at
least five multiple-unit, single-stack plants as being a single source (Elmer Smith 1 & 2, Grant Town 1

395


-------
& 2, Morgantown Energy Facility 1 & 2, Scrubgrass 1 & 2, and Seward 1 & 2). At a minimum, the EPA
must be consistent on this point in order to avoid additional methodological error.

Response to Comments 3-4: The EPA disagrees with commenters. As in the Industrial Boiler
NESHAP, the EPA continues to believe that the emissions from the common stack represent the average
emissions of the EGUs exhausting to the common stack and are representative of both EGUs.
Commenters have provided no data to support the contention that this assumption is false. In addition,
commenters contention that distinct EGUs (i.e., boilers) are one source if they emit out of a common
stack is not consistent with the CAA section 112(a)(8) definition, which clearly applies to the individual
boiler units with a capacity of more than 25 MW. It would not be reasonable in light of that definition to
consider the emissions from two boilers to a common stack as the emissions of one EGU. The EPA used
data from combined stacks only where both EGUs were operating or where the owner/operator certified
that no air in-leakage could occur. . The EPA expects that companies will comply with the final rule by
conducting testing at the common stack as that is usually where the sampling locations are (rather than
in the intermediate ductwork) and will report the results as being for each EGU.

The EPA has reviewed the data based on comments received and does not believe that there are any
inconsistencies in the data set used for the final rule. In the MACT floor analysis, the EPA used data
only from stacks that were tested or for which test data were provided. These stack measurements were
not used to represent emissions from other, non-tested, stacks in the MACT analysis.

The ICR required owners or operators to provide the agency with information from individual EGUs,
and those owners or operators certified the results submitted to the agency as being true, accurate, and
complete. The agency has no ability to and needs not change such submitted data, for if after
submission, an owner or operator believed his/her EGU data from a combined stack were inaccurate, he
or she could have and should have conducted additional testing to isolate emissions. The agency
maintains its use of submitted data for rulemaking purposes remains valid.

3. Common stack provisions.

Comment 5: Several commenters (15678, 17733, 17796) support the approach of applying the most
stringent standard to each EGU when they share the same stack and/or controls. Commenters (17733,
17796) add that this should apply when there are similarly fueled units. Commenter 17796 states this
would eliminate any possible confusion about the applicable regulatory requirements for both regulators
and source owner.

Response to Comment 5: We agree with the commenters and have included such requirements in the
final rule.

Comment 6: Commenter 17775 states that the EPA's proposed common stack provisions fail to provide
sufficient flexibility for EGUs with different control technologies that vent to a common stack. The
commenter states that under proposed section 63.10009(h)(i), two or more units that vent through "a
common control system" to a common stack may be treated as a single unit, and some units with one
common control (e.g., an FGD) may not share other controls (e.g., SCR). The commenter asserts that
although such units may be able to meet the proposed emission limit at the common stack during normal
operation, any significant outage at one unit could make compliance on a 30-day rolling average basis
impossible. The commenter states that the EPA addressed the issue of outages for single stack units
participating in averaging plans under section 63.10009(b) by providing a 12-month rolling average
compliance period and should provide the same for common stack units that use averaging to comply.

396


-------
Response to Comment 6: We have addressed common stack issues elsewhere in this document. We
continue to believe that the emissions of the common stack represent those of all of the EGUs ducting
through that common stack. Should this present problems for the owner/operator, they are free to
conduct their compliance or CEMS testing in the ductwork prior to the common stack so as to measure
emissions from the individual EGUs.

Comment 7: Commenter 17781 states as currently written, paragraphs (h), (i) and (j) do not seem to
address the likely situation where each of the EGUs associated with a common stack are affected units
within the same category, but they do not utilize common control devices (i.e., each EGU is equipped
with its own control device(s)). The commenter states that if the EPA is concerned about a possible
conflict in testing frequency in cases where different control technologies are employed
by EGUs sharing the common stack, the EPA could stipulate that the testing frequency for the common
exhaust stack is based upon the most frequent testing schedule for any of the individual units sharing the
common stack based upon the individual EGU control technologies and common stack compliance
method.

Response to Comment 7: The final rule includes simplified testing frequency requirements and there
may be fewer situations of multiple and different testing frequencies applying to units sharing a common
stack. We agree with the commenter that in any case the more frequent testing requirement must apply
to testing for that common stack.

397


-------
5C06 - Compliance: Startup, Shutdown, and Malfunction

Commenters: 15678, 16849, 17174, 17197, 17283,

17637, 17638, 17648, 17675, 17677, 17689, 17691,

17720, 17722, 17724, 17725, 17728, 17729, 17730,

17757, 17758, 17761, 17767, 17772, 17774, 17775,

17815, 17816, 17820, 17821, 17851, 17856, 17868,

17886, 17902, 17904, 17909, 17912, 17923, 17925,

18034, 18037, 18428, 18429, 18447, 18449, 18450,

19121, 19122, 19536, 19537, 19538, 18023

1. Emission standard applicability during SSM.

a. Support or oppose SSM approach.

Comment 1: Commenters (15678, 17880) support the EPA's approach that emissions standards apply at
all times. Commenter 17648 states that the EPA proposed reasonable and appropriate emission
limitations applicable to SSM periods, and cites the Sierra Club decision. Commenter
19536/19537/19538 states that sources must comply with emission standards at all times, including
startup, shutdown and malfunctions. Sierra Club v. EPA, 551 F.3d 1019 (D.C. Cir. 2008). Commenter
18450 supports that emission limits include startup and shutdown, since these emissions are readily
quantifiable.

Comment 2: Commenter 17851 states that the EPA's requirement to meet steady-state standards during
SSM events is not logical and is not lawful. Commenter 17851 states that from a physical and legal
standpoint, it makes no sense to group SSM and normal operation events under the same set of
standards. Commenters (17740, 17772, 17821, 17868) state that including SSM in the standard is
unreasonable.

Commenter 17772 states that the CAA unambiguously requires that the EPA look to the actual
performance of actual units including performance during periods of start-up, shut-downs, malfunctions.
Instead, the EPA started with very limited data from EGUs operating under ideal conditions- generally
three hours of operation at full load. As a result, the data were skewed towards a performance level that
none of the EGU's from which data were collected can "achieve in practice." Each of those EGU's, and
every other EGU in the country, has start-ups, shut-downs and malfunctions where emissions will be
substantially higher than the performance that can be achieved under full load and ideal operating
conditions.

Commenter 17868 states that the test operations and statistical treatment of the test data do not represent
periods of startup, shutdown, or malfunction. Therefore those periods of operation should not be subject
to the standards. A work practice approach, similar to that promulgated for industrial boiler HAPs,
would be appropriate for these abnormal operating periods. Second, the continuous compliance
assurance requirements - which include enforceable limits on various fuel and hardware variables like
the pressure drop across a control device - are effectively more stringent than the emission standards
that they support, and therefore were not "achieved in practice" by the best controlled units.

Comment 3: Multiple commenters cite concerns about how the rule addresses SSM emissions and made
statements such as the following regarding SSM:

17316,
17702,
17732,
17776,
17870,
17928,
18498,

17383,
17704,
17736,
17795,
17876,
17930,
18500,

17386,
17705,
17737,
17796,
17877,
17975,
18539,

17402,
17712,
17740,
17801,
17878,
18014,
19032,

17622,
17714,
17752,
17807,
17880,
18018,
19040,

17623,
17715,
17755,
17808,
17881,
18021,
19114,

17627,
17716,
17756,
17813,
17885,
18025,
19120,

398


-------
•	MACT standards are too stringent (17383, 17623, 17689, 17712, 17740, 17761, 17772, 17774,
17813, 17816, 17877, 17885,)

•	Emission limits are too low for coal- and lignite-fired units to meet and still remain economically
operational (17930)

•	SSM makes the standard more stringent (17730, 17868, 17902)

•	SSM is a significant burden (17774, 18447)

•	Concerned that the emission limits apply at all times, including SSM periods (17197, 17675,
17725, 17728, 17729, 17732, 17736, 17737, 17756, 17758, 17761, 17774, 17775, 17808, 17815,
17870, 17886, 17904, 17912, 17928, 17930, 17975, 18037, 0234-19536/19537/19538, 0234-
18023)

•	State limits should not apply during SSM periods (17383, 17704, 17712, 17724, 17720, 17725,
17730, 17736, 17752, 17774, 17813, 17820, 17868, 17876, 17885, 17904, 17909, 17925, 18014,
18429, 18498, 19032, 19120)

•	SSM data should not be included in the 30-day average (16849, 17627, 17767, 17772, 17774,
17904, 18428, 19120)

•	Including SSM could result in exceedances of the 30-day standard or noncompliance (17730,
17868, 17930)

•	Requests an exemption during SSM periods (17637, 17820, 18498).

Comment 4: Commenter 17930 states that the EPA has a long history of exempting SSM periods from
NSPS and NESHAP, and this should continue. Commenter 19121 states that startup and shutdown
emissions have historically been exempt. Commenter 17851 states that before the Sierra Club v. EPA
decision, the D.C. Circuit consistently held that technology-based standards must contain exemption or
less stringent standards during SSM than would apply during steady state periods, and cites several court
cases regarding the EPA's previous treatment of SSM events, including, Portland Cement Ass 'n v.
Ruckelshaus (1973), Essex Chem. Corp. v. Ruckelshaus (1973), NRDC v. EPA (1988), Marathon Oil v.
EPA (1977), and National Lime Ass 'n v. EPA (1980). Commenter 17851 states that now that the court
decided that MACT standards must apply during SSM, the EPA must develop standards that are
"achievable" during those events.

Comment 5: Commenter 17856 sees many compliance and enforcement issues arising from the startup
and shutdown provisions. Commenter suggests the EPA adopt reasonable startup and shutdown
provisions.

Comment 6: Commenter 17868 provides an example calculation and a graph showing the hours of
SSM it would take to exceed the 30-day standard as a function of normal emission rate, given various
SSM emission rates in lb/MMBtu. In the example calculation, commenter 17868 states that if the normal
emission rate is 0.02 lb/MMBtu and the startup emission rate is 0.45 lb/MMBtu, then a unit could have
only 16.7 hours in startup before exceeding the standard. Commenter 17868 states in another example,
that for a normal emission rate of 0.28 lb/MMBtu PM and a startup emission rate of 0.45 lb/MMBtu,
then the unit could have only 3.4 hours before exceeding the standard.

Commenter 17867 states that unlike the Industrial Boiler MACT, which requires work practice
standards be met during periods of startup and shutdown, the Utility NESHAPs Rule requires numerical
emission limits. The EPA asserts that startup and shutdowns are predictable and routine aspects of
source operations; thus, a 30-day averaging period should be sufficient to smooth any startup and
shutdown emissions. The commenter disagrees with this assertion. Startups and shutdowns are not
always routine and a 30-day averaging period will not always be enough to smooth out the emission

399


-------
averages. The EPA has not provided justification as to why the work practice standards, as allowed
under CAA 112(h), should not apply during periods of startup and shutdown. The commenter
recommends that the EPA should adopt work practice standards during periods of startup and shutdown
for sources subject to the rule.

Response to Comments 1-6: For periods of startup and shutdown, the EPA is finalizing work practice
standards instead of numeric emission limits. See the preamble for discussion. The EPA's rationale for
its approach to malfunctions is discussed in the preambles to the proposed rule and this final action.

b.	Economic.

Comment 7: Commenter 17772 states that the capital cost of compliance is related to how
startup/shutdown periods are handled and the filterable PM limit, in that including startup/shutdown
emissions in 30-day rolling averages may force companies to install additional multimillion dollar
controls that may not otherwise have been necessary. Commenters (17815, 17904) state that installing
additional APCDs to target startup/shutdown emissions does not make economic sense considering the
startup/shutdown time and the amount of emissions contributed to overall EGU emissions.

Response to Comment 7: For periods of startup and shutdown, the EPA is finalizing work practice
standards instead of numeric emission limits. See the preamble for discussion.

c.	No APCD experience.

Comment 8: Commenter 18498 states that facilities have no experience with the APCD and additives
necessary to comply with the standards, and facilities cannot predict what emissions may occur during
startup/shutdown or how compliance can be achieved during those periods. Commenter 17912 fails to
understand how a new or reconstructed facility can design, build, or operate APCD that must meet a
standard at all times, including SSM periods, when the facility has no way of knowing through any
scientific means or method what the "compliance standard" for continuous compliance will be until the
equipment is first tested. Accordingly, the commenter requests that the agency remove this requirement
and replace it with a number derived from the ICR data base with a reasonable allowance added for the
operational flexibility needed to assure compliance under the "worst foreseeable circumstances."

Response to Comment 8: For periods of startup and shutdown, the EPA is finalizing work practice
standards instead of numeric emission limits. See the preamble for discussion. The EPA's rationale for
its approach to malfunctions is discussed in the preambles to the proposed rule and this final action.

d.	Not able to achieve the standard.

Comment 9: Multiple commenters (17383, 17689, 17712, 17740, 17813, 17876, 17885, 17930, 19032)
state that applying MACT limits during startup/shutdown places the source at risk of noncompliance.
Commenter 17775 states that limited data from startup and shutdown events show these events can
cause significant compliance concerns. Commenters (17774, 17877) state that the EPA has no factual
basis to conclude that even the best performing sources can achieve the standards. Commenter 17736
states that the EPA's flawed assumptions are devastating in that some of the most technologically
advanced units (controlled with overfire air; SCR; FGD; and FGD plus SCR) will not be able to achieve
the MACT limits during SSM periods. Commenter 17795 states that some units may be forced to
operation at economic loss for no reason other than to generate enough full load operating data to
comply, and potentially displacing units that have fewer emissions.

400


-------
•	Commenters (17736, 19122) state that just a few hours of noncompliance during SSM can
destroy/exceed the 30-day rolling average.

•	Commenter 17925 states that several startups can occur in a 30-day period and cause
noncompliance.

•	Commenters (17383, 17689, 17712, 17724, 17813, 17876, 17885) note that more than one
outage could mean noncompliance.

•	Commenter 17868 states that one outage could cause an exceedance.

•	Commenter 19032 states that outages could put a unit in noncompliance.

•	Commenter 17868 states that forced outages are out of the utility's control.

•	Commenters 17756, 17775, 17820 state that units with more than one SS will be penalized with
significantly higher emissions and also a smaller number of operating hours.

•	Commenter 17767 states that if a unit that experiences a difficult, lengthy startup, compliance
with the 30-day averages would be difficult or unachievable.

Response to Comment 9: For periods of startup and shutdown, the EPA is finalizing work practice
standards instead of numeric emission limits. See the preamble for discussion. The EPA's rationale for
its approach to malfunctions is discussed in the preambles to the proposed rule and this final action.

e. 30-day average not sufficient.

Comment 10: Commenter 17904 believes the EPA has taken a positive step in establishing a 30-day
average. Commenter 19121 generally supports the 30-day average, if non-Hg HAP are to be regulated.

Comment 11: Commenter 17877 states the 30-day averaging period is not sufficient to allow
compliance. Commenter 16849 states the 30-day average period is too short. Commenters (17807,
17886, 17925) state that the EPA has not demonstrated the 30-day averaging period will enable
compliance. Commenter 17740 states that varying operating modes experienced by EGUs make a 30-
day averaging period impractical or impossible. Commenter 17930 states that 30-day average is not
sufficient to account for the variability of lignite.

Comment 12: Several commenters (17775, 17795, 17877, 17925) state that a 30-day averaging period
is not sufficient to account for startup/shutdown emissions. More specifically:

•	Commenter 17877 states that 30-day average is not sufficient where multiple SS occur.

•	Commenter 18428 states 30-day average is not sufficient to account for varying load conditions
and SS.

•	Commenter 17728 states the EPA cannot assume that a longer averaging period accounts for
startup/shutdown, and the EPA provides no data to support the assumption.

•	Commenter 17740 states that examination of EGU operations demonstrates that a 30-day
average is insufficient to account for variable emissions from multiple startups and shutdowns.

•	Commenter 16849 states that every SSM produces emissions that will be problematic for the
averaging period.

Comment 13: Commenter 17740 states that EPA's statement that EGUs "do not normally startup and
shutdown frequently" effectively, and incorrectly, assumes that all units are operated as base load units.
As the Seventh Circuit recognized in United States v. Cinergy, "[utilities operate power generation
equipment in three general ways: base load, cycling, and peaking." 623 F.3d 455, 459 (7th Cir. 2010).
Non-base-load units start up and shut down frequently, and even supposed "baseload units" are often,

401


-------
and unpredictably, shut down for unit "trips" (i.e. unplanned outages). The EPA further assumes that
basing the proposed standards on a 30-day rolling average will account for any increased emissions
during periods of startup and shutdown. The EPA made this same faulty assumption in the proposed rule
that preceded the Boiler MACT (see 75 FR 32,012-13) and rejected it in the final rule (see 76 FR
15,642). The EPA has not demonstrated that the 30-day rolling average will address the substantial
operating variations among EGUs or even within an EGU. Further, while a number of the MACT pool
EGUs are newer, well-controlled, base load units, the EPA cannot assume that the entire universe of
coal-fired EGUs, even base-loaded units, will operate as reliably as newer units. As EGUs age, they tend
to experience more forced outages than when they were newly constructed. Thus, an older EGU with
highly efficient controls may not be able to meet a 30-day standard in months in which it experiences a
number of forced outages.

Response to Comments 10-13: For periods of startup and shutdown, the EPA is finalizing work
practice standards instead of numeric emission limits. See the preamble for discussion. The EPA's
rationale for its approach to malfunctions is discussed in the preambles to the proposed rule and this
final action.

f. Normal plant operations/outages/describe SSM periods.

Comment 14: Commenter 16849 states that SSM are part of power plant operations and facilities
should not be penalized for these occurrences. Further, commenter asserts that providing no exemption
during startup/shutdown is an unrealistic expectation. Commenters (17878, 19114) state that SS(M) are
part of normal operation. Commenter 17737 states the EPA should consider startups part of normal
operation. Commenter 17772 states that even top performers will have occasional malfunctions and will
have multiple startup/shutdown periods during a year.

Commenter 17740 states that the EPA ignores the fact that EGUs require an extended period of startup
during which equipment (boiler, control devices) are not operating in their normal conditions, and this
extended period cannot be shortened or avoided. Commenter 17737 states that several factors can lead to
multiple startups or long periods of startup, including equipment problems (burner management logic,
ignitors), or problems related to water chemistry, that would prolong the unit getting to temperature.
Commenter 17737 notes that when outage does occur, there may be multiple or long startup attempts
that are more relevant in terms of the EPAs compliance standard based on 30 boiler operating days.
Commenter 17737 provided a list of startups and corresponding bypass times allowed in their Title V
permit in 2010.

Commenter 17795 states that their units startup and shutdown frequently, and note it is not uncommon
for units to have more than four startups in a 30-boiler day operating period. Commenter 17795 provides
a table showing the number of startups during the first 30 days of 2010 for several typical units: unit 1
had 12 startups; unit 2 had 5 startups; unit 3 had 20 startups; unit 4 had 7 startups; and unit 5 had 4
startups.

Commenter 16849 states that cold startup can take 16 hours, and two or three startups in a month will
not allow the facility to meet the SO2 surrogate standard. Commenter 18498 states that the time for
startup depends on the type of startup (cold, warm, hot). Commenter 17740 notes that startup duration
varies depending on the condition of the boiler at the time of startup, i.e., cold starts can take
approximately 72 hours, warm starts up to 18 to 20 hours, and hot starts can take 6 to 8 hours.

402


-------
Commenter 18025 states the majority of APCDs require a period of time to reach peak performance
(temperature and flows). Commenter 18498 states that adequate time is needed for APCD to operate
prior to measurement of filterable PM.

Commenter 17774 states that many units have multiple startup/shutdown events within 30-day period
due to varying load demand or maintenance, and outages that may or may not meet the criteria of
malfunction. Commenter 17740 states it is not uncommon for their plant and other similar units to
experience more than one startup within 30 days due to forced outages and planned maintenance.
Commenter 17316 states that the averaging period is only appropriate if the number of startups is small
and the duration is normal. Commenter 17877 states it is unreasonable to assume a large EGU will only
SS once during a 30-day period.

Commenters (16849, 17923) describe the EGU forced outage rate curve throughout its life cycle as an
inverse bell curve: high forced outage rate when new until issues are resolved, reduced forced outage
period until parts reach their useful life, then increased forced outage rates again as parts must be
replaced.

Response to Comment 14: For periods of startup and shutdown, the EPA is finalizing work practice
standards instead of numeric emission limits. See the preamble for discussion. The EPA's rationale for
its approach to malfunctions is discussed in the preambles to the proposed rule and this final action.

g. Peaking units.

Comment 15: Several commenters (17725, 17820, 18014, 18498) state that even with relatively long
averaging periods (30-day rolling averages), the emissions from nonrepresentative periods could
significantly affect averages, especially for peaking units or other units that come online and offline
frequently. Commenters (17715, 17757, 19114) state that including startup/shutdown periods have a
great effect on peaking units that startup and shutdown more. Commenter 17736 states the EPA failed to
account for the critical operation of peaking units which go through these periods frequently.
Commenters (17316, 17386) state that the averaging period will not work for EGUs (e.g., dispatchable)
that are in service for short periods (e.g., part of a day) and startup/shutdown periods represents a
significant portion of the operating day.

Commenter 17820 states that units that are required to follow load demand will be penalized.
Commenter 17774 states that the EPA does not account for load-following units or units used on a
sporadic basis. Commenter 17774 states that a number of their units follow load, cycle, or are otherwise
subject to numerous startup/shutdown periods. Commenter 17623 states the EPA's analysis is flawed
because it did not account for load following or load cycling facilities, which startup and shutdown on a
more frequent basis and have additional SSM periods.

Commenter 17720 states that use of 30-day averaging period will not smooth out any emission increases
associated with startups/shutdowns that are driven by dispatch decisions by distant RTOs. Commenter
17772 states that many EGUs are RTO members and must follow RTO directives to shutdown or run at
minimum loads.

Comment 16: Commenter 17930 agrees generally that coal-fired baseload units do not SS often,
however this is likely to be less of the norm. Commenter 17704 agrees that base load units do not
typically startup and shutdown frequently, however, that is changing and cite a new nodal system in
Texas that may increase the frequency of startup/shutdown events. Commenter 17795 states that recent

403


-------
regulation changes, Cross State Air Pollution Rule (CSAPR), could cause units to cycle more in the
future placing greater emphasis on potential effect on SSM on average emissions.

Comment 17: Several commenters (17720, 17758, 16849, 17930) discuss the use of renewable fuels.
Commenter 17720 notes that the EPA's assumption that startup/shutdown periods are predictable and
routine does not take into account the increasing impact of renewable resources and the increasing
control of RTOs. Commenters (17758, 16849, 17930) note that the use of renewable fuels will cause
additional startups/shutdowns for fossil-fuel units. Commenter 17758 states while routine maintenance
and repair and transmission upgrades are predictable and routine, the increased cycling (unplanned
outages) to accommodate renewables results in increased startups and shutdowns. Commenters (17758,
16849) note that the overall impact of cycling reduces overall emissions because fossil units are used
less and renewables are used more. Commenter 17758 states the small emission increase during
startup/shutdown periods is likely dwarfed by avoided emissions due to renewable facility operation.
Commenters (17758, 16849) state the EPA should not penalize environmentally friendly practices.
Commenter 17758 states the emission benefits associated with increase operation of renewable
resources exceed those realized by imposing numeric standards during startup/shutdown periods.
Commenter 17868 states that including SSM activities are a concern because of the increasing number
of "load-following coal-fired power plants that backup wind and solar power plants. Further, commenter
17868 states that ramping up and down and the startup/shutdown activities will increase emissions.

Comment 18: Commenter 17796 states that EPA should allow an emission calculation based on an
emission factor for SSM, and suggested a simple calculation based on fuel feed rate multiplied by a
predetermined emission factor will give an accurate measurement of emissions, rather than the onerous
requirement to monitor fuel flow rates and sample fuel to determine heat content and composition.

Response to Comments 15 - 18: For periods of startup and shutdown, the EPA is finalizing work
practice standards instead of numeric emission limits. See the preamble for discussion. The EPA's
rationale for its approach to malfunctions is discussed in the preambles to the proposed rule and this
final action.

h.	Monitoring plan/suggested startup/shutdown approaches.

Comment 19: Commenter 17316 recommends that facilities establish a maximum allowed duration for
startup/shutdown periods in the Monitoring Plan. Commenters (17316, 17386) state if startup/shutdown
hours exceed a certain proportion of total operating hours in the 30-day operating period (e.g., more than
20 percent), then startup/shutdown periods should be excluded from the 30-day average.

Response to Comment 19: For periods of startup and shutdown, the EPA is finalizing work practice
standards instead of numeric emission limits. See the preamble for discussion.

i.	Not clear how SSM included/no basis for standard,
i. General.

Comment 20: Multiple commenters indicate that data used for the MACT floors are not representative
of startup/shutdown conditions, and provided various comments including:

• MACT floor or limit does not account for SS(M) emissions (17623, 17715, 17725, 17757,
17774, 17820, 17851, 17868, 17877, 18014, 18037, 18429, 18498, 19114, 19121, 0234-18023)

404


-------
•	EPA does not account for required shutdowns (17761)

•	EPA does not have emissions data for startups/shutdowns for EGUs (17732, 17756, 17851)

•	EPA never collected and analyzed a sufficient amount of data (17736)

•	Facility does not have startup or shutdown emission data (17722, 17737)

•	EPA does not have sufficient information or data on SS(M) emissions (17795, 17736, 17402)

•	Data was during regular operation (17732)

•	Application of the MACT standards during SSM periods is inappropriate (17623, 17774, 18037)

•	EPA has not accounted for emissions, or higher emission levels, from SS (17730, 17736, 17761,
17772, 17816, 17821)

•	EPA cannot apply a single standard that applies at all times (17732, 17774)

•	Commenter 18429 states it is inappropriate to include SSM in the compliance demonstration

Commenter 17740 states that the EPA fails to consider whether performance standards would be
practicable at EGUs during startup/shutdown periods. Commenter 17722 questions whether the EPA has
correctly evaluated startup/shutdown periods in setting the limits. In addition:

•	Commenters (17197, 17627, 17704, 17715, 17716, 17722, 17724, 17725, 17728, 17730, 17732.
17736, 17752, 17757, 17761, 17767, 17774, 17775, 17808, 17820,17870, 17876, 17877, 17878,
17886, 17904, 18014, 18037, 18428, 18498, 19114, 18023) state that stack testing data submitted
(under the ICR) did not include SSM periods but was for normal, steady-state

operation. Commenter 17851 states that all data was collected under steady-state conditions.
Commenter 17736 states the MACT limits are based on full load steady state testing, and not on
the full range of operating conditions, including changes in operating variables. Commenter
17736 states that data that is limited to a single operating characteristic under Utopian conditions
is insufficient and inappropriate for establishing MACT limits that must be satisfied at all times.

•	Commenter 17767 states that no attempt was made to quantify emissions from
startups/shutdowns during development of the emission limits. Commenter 17925 states no stack
test data exists for startups/shutdown.

•	Commenters 17772, 17774, 18428 state EPA analyzed short-term testing (snapshot) of EGUs
under normal operation conditions. Commenter 19114 states it is impossible to declare the
MACT floor includes variability adjustments for SS when EPA possesses no test data to support
the declaration. Commenter 17761 states the rules fail to account for operational variability and
required shutdowns and do not appropriately represent emissions that can be consistently
achieved.

•	Commenter 17925 assumes EPA used isokinetic stack testing during normal operation, without
regard to actual emissions limit, or used arbitrary non-isokinetic assumptions to quantify SS
emissions.

•	Commenter 17925 does not understand how the EPA integrated startup/shutdown emissions into
the 30-day standard.

•	Commenter 17774 notes in particular that no malfunction data was incorporated into the MACT
floor.

Commenter 17736 states that EPA should recognize these issues, especially when establishing standards
without adequate consideration of data and other information.

Commenters (17383, 17724, 17876) question whether the EPA has accurate startup data for Hg
emissions, state they are not aware of any Hg startup emission data, and note that Hg emissions spike
during startup. Commenters (17383, 17724, 17876) request that the EPA provide a clear analysis of this

405


-------
startup Hg emissions data with respect to the development of the variability calculations and the
standard.

Response to Comment 20: For periods of startup and shutdown, the EPA is finalizing work practice
standards instead of numeric emission limits. See the preamble for discussion. The EPA's rationale for
its approach to malfunctions is discussed in the preambles to the proposed rule and this final action.

ii. The EPA not demonstrated that limits are achievable.

Comment 21: Commenter 19114 states that by setting a limit to include startups/shutdowns but basing
the limits solely on full load, steady-state test data, the EPA is violating the requirements of the CAA to
set achievable standards. Commenter 17772 notes that the EPA's approach understates the true average
emissions of top 12 percent. Commenter 17878 states that the emission standard is lower than the rate
"achieved in practice" by the best performing units. Commenter 17761 states that the EPA
inappropriately established standards that do not reflect the "average emission limitation" achieved by
the best performing 12 percent of existing sources. Commenters (17724, 17876) state the EPA must
evaluate startup/shutdown emissions to demonstrate that the limits are achievable. Commenters (17402,
18037, 18539) state that given the lack of data and that the limited data that are available show
emissions are higher during SS, the EPA has not established an emission standard that can actually be
achieved during SSM, as required by statute. Commenters (17851, 17878) state thatMACT standards
must be based on evidence that sources have achieved them. Commenter 17851 states that standards
must be achievable under the most adverse circumstances which can reasonably be expected to recur.

Comment 22: Commenter 17732 states the EPA should explain what data was used to come to the
conclusion that a single standard can be met at all times, including startup/shutdown periods.

Commenter 17737 states that EPA provides no data or analysis to demonstrate that coal-fired EGUs will
be able to meet the standard including SS periods. Commenter 17851 states the EPA must demonstrate
why facilities can comply with the final standards. Commenter 17851 states that the EPA's statement
that sources can meet the standard during SSM is not based on any data, at least there is not data in the
record. Commenter 17724 states the EPA must evaluate the ICR data to identify startup/shutdown
emissions. Commenter 17722 requests that the EPA demonstrate how the ICR data is inclusive of
startup/shutdown emissions for each regulated pollutant. Commenter 17772 states the EPA failed to
quantify the level of any startup/shutdown adjustment, explain its methodology for taking SSM into
account, and has not used real data for an adjustment, and thus the emission limits are arbitrary and
capricious. Commenter 17815 states it is unclear how much SSM data was included in the analysis.

Comment 23: Commenter 18023 states that the impact of a single startup or shutdown event is
unknown. Commenter 18428 states that representations by the EPA and other stakeholders that a
number of units already meet the proposed limit are based on stack test data and not on continuous
monitoring over 30-day periods, so these representations are incomplete at best. Commenter 18023
states that the EPA has not shown through analysis that startup and shutdown events will not have a
significant impact on the 30-day averages and the EPA has not presented evidence that they accounted
for the impact of startups/shutdowns as it claims, given that the stack test data the emission limit is
based on was collected for full-load steady state conditions. Commenter 17795 states that meeting a
standard based on steady state operations at full load during SSM and load swings by use of a 30 day
averaging period is not supported by data. Commenter 17758 states the EPA has not demonstrated that
the 30-day average will enable compliance, and the EPA's assumption is unsupported by data from
actual units. Commenters (17728, 17729, 17775, 17756) state the EPA has no way of knowing if the 30-
day average is sufficient to address unpredictable startup emissions. If the EPA cannot demonstrate, then

406


-------
commenters (17724, 17876, 19032) state that startup/shutdown periods should be excluded from 30-day
averages.

Response to Comments 21 - 23: For periods of startup and shutdown, the EPA is finalizing work
practice standards instead of numeric emission limits. See the preamble for discussion. The EPA's
rationale for its approach to malfunctions is discussed in the preambles to the proposed rule and this
final action.

iii.	Burner inspection outage.

Comment 24: Commenter 17761 states that at a minimum, with the mandatory burner inspection
requirements that impose an additional startup and shutdown on facilities, the EPA should take into
account the emissions from the mandatory startup and shutdown precipitated by its own rule in
establishing the "best performing" sources. Commenter 17930 states that rule requirements for annual
shutdowns, for burner tune-ups, will increase the frequency of baseload units being shutdown, along
with the suit of other EPA regulations. Commenter 17930 cites the allowance allocations in the CSAPR
that assume units will operate seasonally, which will result in more SSM activity.

Response to Comment 24: In addition to the final rule treatment of startup and shutdown periods
discussed in the responses under this section (see Responses to Comments 1-23, above), EPA also notes
that the final rule adjusts the frequency of burner inspections to once at least every 36 months (or 48, in
certain circumstances), so that the inspections can better coincide with planned unit outages. See further
discussion under section 4D02 of this document.

iv.	Burner inspection requirement.

Comment 25: Several commenters (19536, 19537, 19538) state that during SSM events, organic HAP
emissions are known to increase for short periods due to low boiler combustion temperatures, poor
mixing, and low excess oxygen levels. Commenters state that the proposal is silent as to how an annual
tuneup would assure organic HAP emissions remain controlled during SSM periods.

Response to Comment 25: Under the general provisions of Part 63, all sources must operate and
maintain their sources in accordance with good air pollution control practices to minimize emissions.
Those general provisions, together with the standards that apply (including the specific work practice
standards in the final rule applicable to startup and shutdown periods), will ensure that organic HAP
emissions are minimized from affected sources during SSM periods.

v.	Recommendations for EPA.

Comment 26: Commenter 17622 recommends re-testing of units under the same conditions to verify
emissions are repeatable and sustainable over operating periods that include startup/shutdown periods.
Commenters (17732, 17772, 17774, 17877) state the EPA should collect and analyze data for emission
standards during SS(M). Commenter 17737 states EPA should collect and analyze emissions data to
evaluate the compliance risk associated with inclusion of startup periods in the MACT standard for
normal operations. Commenters (17815, 17904) state that the EPA should analyze excess emission
reports to determine the frequency of startups/shutdowns and include that analysis in the standards.

407


-------
Commenter 17795 states the EPA must account for the effect of startup/shutdown emission on a 30-day
average. Commenter 17729 states that setting the PM limit as the actual emission value measured during
steady-state testing leaves no room for process variability and for startup/shutdown emissions.

Commenter 18021 believes the EPA needs to consider applying adjustments to the limits to allow for
differences in operation conditions. Commenter 17930 states the EPA should increase the emissions
limits for all pollutants to better account for SSM emissions. Commenter 17912 requests that the EPA
replace the requirement with a number derived from the ICR database with a reasonable allowance
added for operational flexibility needed to assure compliance under the worst foreseeable circumstances.

Response to Comment 26: For periods of startup and shutdown, the EPA is finalizing work practice
standards instead of numeric emission limits. This approach is more workable than the use of
adjustments as suggested in some of these comments. See the preamble for discussion. The EPA's
rationale for its approach to malfunctions is discussed in the preambles to the proposed rule and this
final action.

vi. Variability component.

Comment 27: Several commenters (17725, 17820, 18014, 18037, 18498, 18539) state that the EPA
does not have sufficient data (either reference method or CEMS data) to address variability during
SS(M) periods and load changes (17820). Commenters 17730 and 17761 state startup/shutdown
emissions must be adequately accounted for in the variability component. Commenter 17886 states the
EPA should revise its variability adjustment to account for long term unit emissions variability.
Commenters 17724 and 17876 state that the variability component of the MACT floor calculation drives
the final emission limit more so than the mean value of the data set. Commenters 17724 and 17876
further state that the variability component could be drastically different with inclusion of
startup/shutdown emissions data, resulting in a higher limit. Commenter 17722 states the EPA would
develop a much different emission limit if startup/shutdown emissions were in the data sets.

Response to Comment 27: For periods of startup and shutdown, the EPA is finalizing work practice
standards instead of numeric emission limits. See the preamble for discussion. The EPA's rationale for
its approach to malfunctions is discussed in the preambles to the proposed rule and this final action.

j. SSM results in increased emissions/distinct operating modes.

Comment 28: Commenters 17730 and 17740 state SS(M) periods are distinctly different modes of
operations from normal operation. Commenters 17705 and 17757 state that startup/shutdown periods
have different emission characteristics than emissions during normal operations. Commenters 17715 and
19114 state that startup/shutdown emissions are not similar to steady state full load emissions.
Commenter 17878 states that SSM periods result in increased emissions rates. Several commenters
(17715, 17757, 17856, 19114) state increased emissions during startups/shutdowns could skew the
average emission rate. Commenter 17851 states that non-steady state emissions could alter the EPA's
calculations. Commenter 17705 states that other transient conditions such as significant load changes
will result in emissions in excess of those measured during initial performance tests. Commenter 17851
states that emissions during non-steady state conditions may vary significantly.

Several commenters (17808, 17870, 18025) note that, as in the Boiler MACT, malfunctions should not
be considered a distinct operating mode. Commenter 17851 disagrees with the EPA that malfunctions
are not distinct operating modes.

408


-------
Commenter 18023 states that startup is a distinct operating period and it should be considered
independently. Commenter 18023 provides Hg CEMS data showing two distinct emission profiles for
periods of startup (when SCR is offline due to low temperature) and for periods of steady-state with full
control (when both SCR and FGD APCD systems are operating). Commenter 18023 further states that
steady-state emissions data do not represent emissions during startup/shutdown periods.

Commenter 17775 states that long-term Hg and PM CEMS data show spikes in emissions that are likely
due to startup/shutdown events. Commenter 18428 has reviewed Hg CEMS data from 2 coal-fired units
and states that the data spike above the proposed standard (1.2 lb/trillion Btu) is likely due to
fluctuations.

Commenter 18449 states that startup results in very high stack Hg concentration for a short amount of
time, most likely from Hg deposited on ducts and other surfaces, although Hg emissions are not
necessarily high since the flow rate is very low. Commenter 18449 provides graphs with actual startup
Hg emissions from Hg CEMS; the normal emissions are 3 to 4 ug/m3, with an ESP and SCR.
Commenter 18449 states that the short transient nature of SSM events causes severe errors in estimating
hourly mass emissions based on multiplying hourly averages of pollutant concentration and hourly
average of stack flow; these problems are worse when the mass is normalized to lb/GWhr using a 5
percent of full power output, which will artificially inflate the emissions rate by a factor of 20 and added
to the rolling average, even though the actual mass emissions may not be significant during SSM.
Commenter 18449 states this is punitive.

Commenter 17772 states that their facility has 18 months of PM CEMS data with startups/shutdowns
included that shows fully controlled units will not be able to comply with the emissions limit. The
commenter provides graphs of 30-day boiler operating day average data for three units, and provided
data showing the wide difference between PM CEMS data with and without startup/shutdown data. (See
Figures 1 through 3 and Table 3 of letter, Docket Item No. The EPA-HQ-OAR-2009-0234-17772.) The
commenter indicates that 0.018 lb/MMBtu is representative value for filterable PM, however, with
startup/shutdown values included, the representative value is 0.29 lb/MMBtu (includes low flow rates,
high concentrations, and CO2 diluent of 5 percent), which is 16 times higher.

Commenter 17795 provides average SO2 emissions data for 30 boiler operating days that include two
startups, showing that SSM occurred for 10 percent of operating hours during the period and that
including SSM emissions results in an increase of 13 percent in the 30-day average emission rate.

Response to Comment 28: For periods of startup and shutdown, the EPA is finalizing work practice
standards instead of numeric emission limits. See the preamble for discussion. The EPA's rationale for
its approach to malfunctions is discussed in the preambles to the proposed rule and this final action. In
addition, one commenter maintains that the during SS and M periods there are fluctuations in the
monitoring, but the commenter also refers to a provision in the proposed rule that allowed sources to
assume a 5 percent of full capacity factor for periods of startup and shutdown. The 5 percent conversion
is no longer included in the rule because we are establishing work practice standards for such periods.
Because the proposed 5 percent factor does not apply to malfunction periods, the comment concerning
artificial inflation of the emissions rate is not relevant to periods of malfunction. The final rule requires
source owners who use continuous monitoring to measure emissions during malfunctions periods. We
believe that it is important to collect data during all process operating periods including SSM periods, as
the rule requires when conducting any continuous monitoring (see additional responses below relative to
the accuracy and utility of such data). The agency also believes EGU owners or operators strive to
minimize periods of malfunction and should a malfunction period occur, its duration will be brief, as

409


-------
noted by the commenter. Any impact of potential excess emissions occurring during a period of
malfunction should be offset to some degree through use of the rule's 30 boiler operating day rolling
average requirement. To the extent the CEMS records an exceedance during a malfunction, and the
owner or operator believes the measurement was in error, the owner or operator can demonstrate that the
source complied with the standard notwithstanding the CEMS measurement using any available
information. See also responses below that address the issue of determining compliance during
malfunction events.

k. Use of CEMS during startup/shutdown.

Comment 29: Several commenters express concerns regarding the use of CEMS for measurement
during startup/shutdown. Commenters (17677, 17728, 17729, 17775) also indicate it is not feasible to
measure compliance with CEMS during startup; commenters cited the following issues for
startup/shutdown, including temperature issues (17728, 17729, 17815), low flow rate (17815, 17728),
and varying moisture (17729). Commenter 18498 states that particulate size varies during
startup/shutdown and cannot be measured accurately by PM CEMS. Commenter 18498 states that
startup/shutdown periods present wide variations depending on the process and control equipment.
Commenter 17728 states the EPA does not account for the absence of correlated PM CEMS during
startup/shutdown periods. Commenters (17728, 17736, 17752, 17772) state the PM CEMS correlation
curves do not include any data during SSM periods. Commenters (17728, 17752) state the PM CEMS
cannot be correlated and the accuracy of PM CEMS data during those conditions is unknown, and
commenter 17736 states the correlation can only be done during normal operating loads. Commenter
18498 states that PM CEMS are calibrated for normal operating conditions. Commenter 18498 states
that startups/shutdowns present significantly different conditions that are not part of PM CEMS
calibration.

Commenters 17677 and 17775 state that CEMS are not correlated to startup/shutdown periods because
the EPA reference test methods were not designed for transient or dynamic plant operations. Commenter
17677 questions the enforceable value of these data, and states the EPA needs to consider the ability for
CEMS to accurately monitor emissions in startup/shutdown periods. Commenter 17772 states the PM
CEMS data from startups/shutdowns are not reliable and highly variable. Commenter 17886 states they
do not know of valid test or CEMS measurement techniques for HAP during startups/shutdowns.
Commenter 17736 states that most units do not start up on coal but use other fuels (e.g., fuel oil), and a
PM CEMS that was correlated for coal does not measure emissions accurately. Several commenters
(17725, 18014, 18498) state that particle size distribution or unburned levels during startup affect PM
CEMS measurement accuracy, particularly those using light scattering or optically-based technologies;
commenter 17728 states that the particle size distribution may differ from those in the correlation.

Several commenters (17725, 17820, 18014, 18498) state that including SSM is critical for units using
PM CEMS to demonstrate continuous compliance, since part 63 no longer includes exemptions for
SSM.

Commenter 17925 states that there are very few CEMS in operation to provide data to confirm that
limits can be met during startup/shutdown.

Commenters 17774 and 17821 relay that there are operation problems for sorbent trap CEMS to
demonstrate compliance with Hg limits during startup; Commenter 17774 cites the following for sorbent
trap CEMs: demonstrate poor performance, flue gas conditions are unacceptable, and interferences cause
breakthrough.

410


-------
Response to Comment 29: For periods of startup and shutdown, the EPA is finalizing work practice
standards instead of numeric emission limits and thus commenters concerns related to reliance on CEMS
during such periods is moot. See the preamble for discussion. The EPA's rationale for its approach to
malfunctions is discussed in the preambles to the proposed rule and this final action.

With respect to commenters' concern that PM CEMS cannot be correlated and the accuracy of PM
CEMS data during malfunction periods is unknown, see responses below that address the issue of
determining compliance during malfunction events.

1. The EPA assumptions/justifications.

i.	Support or oppose EPA's assumptions.

Comment 30: Multiple commenters (17728, 17740, 17758, 17774, 17775, 17807, 17808, 17851, 17870,
18023) disagree with the EPA's rationale and assumptions for including startup/shutdown in the MACT
standard. Commenter 17740 states that the EPA's justification for not establishing different
requirements for startup/shutdown (include (1) EGUs do not normally startup and shutdown frequently,
and (2) EGUs typically use cleaner fuels during startup) are unsupported and do not reflect actual EGU
operating practices). Several commenters (17728, 17729, 17756, 17775) state the EPA's rationale does
not account for the variety of ways EGUs startup and shutdown (types of fuel, duration varies), and is
not based on actual emission observations during startup/shutdown (17728, 17775). Commenter 17807
states the EPA has not justified these assumptions based on actual startup/shutdown data.

Multiple commenters cited concerns about EPA assumptions regarding SSM and made statements such
as the following: startup/shutdown periods are predictable and routine (17691, 17821); startup/shutdown
periods are not predictable and routine (17807, 17758); EGUs do startup and shutdown frequently
(18447); base load units do have startups and shutdowns (17772); EGUs do not startup frequently
(17851); solid fuel-fired EGUs startup infrequently (17815); the duration of startup/shutdown is
reasonably predictable (17316, 17386); the duration of startup can vary significantly (17756); the
emissions during startup are variable (17316, 17386), due to transient combustion conditions (17386),
affected by length of time unit has been shutdown (17316, 17386), and affected by ambient conditions at
lite-off (17386); the number of startups in a given period can vary (17756); frequency and duration of
startup/shutdown varies by unit and fuel blend (17758, 17807); base load units generally operate for
long periods without an outage (17737); and historically, planned outages for maintenance and repair
were fairly predictable and routine (17720, 17758).

Response to Comment 30: For periods of startup and shutdown, the EPA is finalizing work practice
standards instead of numeric emission limits. See the preamble for discussion. The EPA's rationale for
its approach to malfunctions is discussed in the preambles to the proposed rule and this final action.

ii.	Cleaner fuels.

Comment 31: Commenter 17740 states that units burn a wide array of fuels and the EPA cannot assume
without additional justification that EGUs rely on cleaner fuels during startup. Commenters 17740 and
17774 also state that emissions may be higher than normal during startup periods, even when alternative
(cleaner) fuels are used. Commenter 17728 states the EPA cannot assume that use of cleaner fuels
accounts for startup/shutdown periods, and the EPA provides no data to support the assumption (flue gas
conditions and particle size distribution may differ significantly during startup/shutdown than other
periods). Commenter 17737 takes little comfort in the EPA's assertion that emission exceedances will

411


-------
not occur due to use of clean fuels during startup. Commenters 17737 and 17772 state that they use oil
during startup with APCD bypass (FF, ESP) to avoid oil residue fouling, and Commenter 17737 states
that bypass occurs until flue gas entering the FF is 160 °F. Commenter 17756 states that they use oil for
some units and use NG for others during startup. Commenters 17702 and 18018 state that many EGUs
use oil for startup when NG is not available. Commenter 17702 states the EPA should consider an
exception during startup/shutdown when an EGU is forced to use oil or when NG is not available.
Commenter 17758 states the EPA has not provided support that use of different fuel for
startup/shutdown would minimize emissions. Commenters 17815 and 17904 agree that solid fuel-fired
EGUs typically startup on cleaner fuels, however note that some fire and transition to solid fuel during
startup.

Commenters 17808 and 17870 state that most EGUs will switch fuels during startup, but for shutdown
some will not switch fuels. Commenter 17702 states that manufacturer protocols for control equipment
require additional delays for equipment startup when oil is used.

Response to Comment 31: For periods of startup and shutdown, the EPA is finalizing work practice
standards instead of numeric emission limits. See the preamble for discussion.

iii. Combustion inefficient.

Comment 32: Commenter 17925 states that combustion is unstable (during startup), and design
emission rates may not be achieved. Commenter 19114 states there are increases in products of
incomplete combustion (PICs) (during startup). Commenter 17851 states that even when using cleaner
fuel, the combustion process is inefficient during startup. Commenter 17851 notes that incomplete
combustion would not impact fuel-derived HAP but would impact organic and PM emissions.
Commenter 17904 states that boilers may not perform at the same efficiency during startup/shutdown.

Response to Comment 32: For periods of startup and shutdown, the EPA is finalizing work practice
standards instead of numeric emission limits. See the preamble for discussion.

m. APCD not operated.

Comment 33: Numerous commenters (17316, 17386, 17402, 17623, 17675, 17715, 17740, 17757,
17774, 17820, 17851, 17904, 17930, 18539, 19114) state that APCDs do not operate during startup or
most of startup; commenters (17725, 17757, 17820, 17904, 18014, 18498) state some emission controls
should not operate until the system comes to the proper temperature or other conditions; commenter
17756 states that different control devices are brought online at different stages of startup.

Commenter 18018 states that manufacturer's often require delays for APCD for startup when using oil
and not NG. Commenter 18018 states that the EPA should consider an exception to the compliance
provision when an EGU is forced to use oil or NG is not available.

Multiple commenters (17623, 17702, 17740, 17774, 17815, 17904, 17930, 17975, 18018, 19114)
indicate facilities follow manufacturer recommendations and/or good engineering practices for APCDs.
Commenters (17815, 17904) state that solid fuel-fired EGUs operate with manufacturer-established
constraints on APCDs during startup. Commenter 17815 states that manufacturer limits on APCD
constrain an EGU's ability to comply with the standard during startup/shutdown. Commenter 17925
states that APCDs are not designed for higher loadings during startup/shutdown. Commenter 17930
states that manufacturer's recommendations protect APCDs against failure, explosive conditions, and

412


-------
ensure long-term functionality. Commenter 17740 states that EGUs have very few options for
controlling, monitoring, or limiting emissions during periods of startup/shutdown due to equipment
integrity concerns, technological limitations, and safety issues.

Multiple commenters indicate that APCDs are bypassed under certain operating conditions. Commenter
19114 states that APCDs need to achieve stable operating temperatures or other conditions. In general,
fabric filters must have a specific stack gas temperature to avoid damage or failure of the bags (17851,
17740, 19121), and damage to the FF (17740, 19121). Commenter 19121 states that FF use during high
loading of fuel oil cause bag blinding. Commenter 19121 states that use of FF during startup/shutdown
may require replacement of all bags from each startup/shutdown event, and with five startups per year,
this would be costly and may impact capture efficiencies. In general, ESPs must have a specific stack
gas temperature (17740, 17930) to avoid short-term stability problems (17740), unsafe actions and long-
term degradation due to fouling (17740), increased chances of wire damage (17740), or increased
corrosion in chambers (17740). Commenter 17930 states that ESPs are on 85 percent of the coal-fired
fleet. Commenter 17740 states that SDA require a minimum temperature, because the slurry feed rate is
limited by the amount of moisture that the flue gas can evaporate. Commenter 17881 states that
requiring the FGD system to operate during SSM, if technically feasible, is a waste of reagent,
increasing ratepayer costs while providing no emission reduction or environmental benefit, damaging
equipment and further resulting in unplanned shutdowns.

Commenter 18447 cites concerns for the safety ramifications of the rule. Commenter 18447 states that
the EPA does not understand how to operate a boiler and the procedures that are necessary to operate
safely during startup/shutdown. Commenter 18447 states that during shutdown or malfunction, the fuel
to the boiler is shutdown and the ESP is powered down, to prevent unburned fuel from exiting the boiler
and passing into the ESP where it would be ignited by the ESP if it remained powered up.

Commenter 17740 states that the warm-up time could theoretically be reduced by ramping up the fuel
rate, but plants closely follow OEM warm-up period recommendations to avoid severe refractory
damage and excessive metallurgical stresses due to rapid changes in temperature and wide variations in
temperature across boiler and duct parts. Commenter 17740 states inconsistent heating could cause
immediate failures such as tears or ruptures in support steel or heat transfer surfaces, posing risk to
personnel. Commenter 17740 notes that failure rates would increase if rapid heating and cooling cycles
were conducted, which would further increase startups and shutdowns.

Commenter 17772 states that if cooling pumps fail at shutdown, immediate bypass is necessary to avoid
melting fiberglass tubes.

Commenter 17740 provides an example facility, a single unit plant that has upgraded with installation of
new control equipment (SCR, FGD, and PJFF) that is considered BDT, modification of plant heat
rejection system, and improvements to the boiler. Commenter 17740 states that the plant cannot operate
the SCR and FGD during startup when the flue gas temperatures and boiler steam pressure are lower
than required. The commenter indicates that the current permit limit requires lb/MMBtu for S02 and
NOx on a 30-day rolling average; the plant can meet the permit limits if there is only one startup within
a given 30-day period, however, additional startups significantly jeopardize compliance for S02 and
NOx.

Response to Comment 33: For periods of startup and shutdown, the EPA is finalizing work practice
standards instead of numeric emission limits. These work practices take into account operation of

413


-------
APCDs. See the preamble for discussion. The EPA's rationale for its approach to malfunctions is
discussed in the preambles to the proposed rule and this final action.

n. APCD not efficient.

Comment 34: Numerous commenters (17402, 17623, 17705, 17715, 17725, 17736, 17757, 17758,
17772, 17774, 17807, 17808, 17820, 17821, 17870, 17877, 17902, 18014, 18498, 18539, 19114) state
some APCDs do not operate efficiently (or optimum performance) during SS(M) periods. Commenter
17736 states that even the most advanced technologies have lower removal efficiencies during
startup/shutdown periods. Commenter 17736 states that the EPA failed to recognize that control
technologies cannot achieve the relied-upon result every hour of each day of the year. Commenter 17772
states the EPA must recognize how APCDs function and the limitation of APCDs during SSM in order
to develop reasonable and achievable standards. Commenter 17623 states it is not practicable to meet the
same stringent standards as would be required when APCD is fully functioning. Several commenters
(17758, 17772, 17774, 17807, 17821) state that emissions may be greater during startup/shutdown
periods because APCDs do not operate efficiently until steady-state is achieved. Commenter 17856
states S02 emissions are higher from the scrubber and NOx and Hg emissions from SCR are higher
during first few days of startup. Commenter 17725 states there may be periods when a source would not
be able to comply with the standards because the control device does not operate at peak performance
until certain operating conditions and flue gas temperature are achieved. Commenter 17821 states that
FGD systems require 24 to 36 hours for startup to develop the proper scrubber liquor chemistry, and to
achieve the SO2 emission reduction.

Commenter 17736 states that ESPs yield lower removal efficiencies during startup due to low
temperatures; Several commenters (17736, 17772, 17821) state that SCR effectiveness cannot be
realized until the unit reaches a specific temperature. Commenter 17821 notes that the SCR performance
impacts Hg oxidation and stack Hg emissions and therefore impacts the ESP performance. Commenter
17772 states that SCR contribution to Hg removal is high during normal operation, with the scrubber
and ESP achieving 90 percent Hg removal, but is minimal during startup where the scrubber and ESP
achieve approximately 65 percent Hg removal.

Commenter 17975 states that the EPA has failed to consider whether FF or other APCDs can
substantially reduce emissions during startup/shutdown and maintenance. Commenter 17975 states that
if other APCDs can reduce emissions, the PM limits must be based on superior technologies and not
those APCDs that are not designed to operate effectively during startup/shutdown.

Response to Comment 34: For periods of startup and shutdown, the EPA is finalizing work practice
standards instead of numeric emission limits. These work practice standards take into account operation
of APCDs. See the preamble for discussion. The EPA's rationale for its approach to malfunctions is
discussed in the preambles to the proposed rule and this final action.

0.	Rule clarifications.

1.	Definition for SSM.

Comment 35: Several commenters (19536, 19537, 19538) state that the EPA does not define startup,
shutdown, or malfunction.

414


-------
Response to Comment 35: The rule describes what constitutes startup periods and shutdown periods in
Table 3 to Subpart UUUUU of Part 63. Table 9 indicates that the definition of malfunction contained in
general provisions (40 CFR Part 63.2) applies.

ii.	Period for emissions averaging.

Comment 36: Commenters 17808 and 17870 state that averaging emissions over 30 boiler operating
days is only relevant for CEMS but is not relevant for units conducting monthly or quarterly
performance testing because these EGUs are not averaging emissions during startup/shutdown periods.

Commenter 17772 suggests that an annual limitation measured could be established for SSM periods for
uncontrolled emissions for some limited number of hours.

Response to Comment 36: The commenters are correct that the 30 (or 90, as discussed elsewhere)
boiler operating-day rolling average will only apply to sources demonstrating compliance through the
use of CEMS or other continuous monitoring mechanisms. For periods of startup and shutdown, the
EPA is finalizing work practice standards instead of numeric emission limits; therefore, the commenter's
suggestion that annual averaging be applied for startup and shutdown periods is moot. See the preamble
for discussion. We do not believe that annual averaging times are appropriate for malfunction events.
The EPA's rationale for its approach to malfunctions is discussed in the preambles to the proposed rule
and this final action.

iii.	Definition of boiler operating day/subpart Da.

Comment 37: Several commenters (17756, 17775, 17820) state the "boiler operating day" definition is
not flexible to account for periods of shutdown, and recommends the EPA specify a minimum number
of operating hours necessary to calculate a 30-day rolling average. The commenters indicate that if the
requisite number of hours is not obtained, then the EGU may combine data from that period with data
from the next 30-day period until the requisite number of hours is obtained. The commenters indicate
this is similar to subpart Da for calculation of a 24-hour average in section 60.48Da(g)(3), which
requires a minimum number of valid hours to calculate an average. Commenters (17820, 17886) suggest
the EPA define a "boiler operating day" as operating 75 percent of the day, or 18 hours or more.
Commenter 17886 states that operating days should be defined as 18 hours or more operation and if less
than 18 hours should be excluded from the 30-day average.

Several commenters (17316, 17386, 17772) indicate that 40 CFR part 60 subpart Da rule revisions
exclude startup/shutdown periods from 30-day averaging. Commenters (17715, 19114) state that
excluding startup/shutdown periods from emission limits would follow precedent in numerous
rulemakings.

Response to Comment 37: For periods of startup and shutdown, the EPA is finalizing work practice
standards instead of numeric emission limits so this comment is moot. These work practice standards
take into account operation of APCDs. See the preamble for discussion.

iv.	Other.

Comment 38: Commenter 17675 states there should be allowances for alternative compliance limits or
alternative monitoring for startup/shutdown periods, especially for acid gas and SO2, when APCD are

415


-------
being brought online (or kept online during shutdown). Commenter 17675 recommends that section
63.9991 (a)( 1 )(iii) be modified to allow a short, 8 to 12 hour, startup.

Commenter 17761 suggests, in conjunction with a longer emissions averaging period, that the EPA
impose a work practice relative to a time limitation on what constitutes a startup or shutdown (e.g., 20
hours for startup, etc.), and to the extent that the startup exceeds the defined time, the facility would
either have to abandon its startup efforts, justify a claim of malfunction, or utilize such emissions during
that extended period in the emission averaging calculation to demonstrate compliance.

Response to Comment 38: For periods of startup and shutdown, the EPA is finalizing work practice
standards instead of numeric emission limits. These work practice standards take into account operation
of APCDs. See the preamble for discussion.

p. Weighting startup/shutdown.

Comment 39: Several commenters suggest that the EPA weight the startup/shutdown emissions based
on heat input. Commenter 17775 suggests weighting startup and shutdown values by heat input would
be a more effective way of normalizing the impact of such events, and is consistent with the rationale
the EPA provided in the proposed revision to 40 CFR part 60, subpart Da. Commenter 15678 states that
fuel specific CO2 concentration should be used for calculating emissions in lb/MMBtu during
startup/shutdown periods.

Commenter 17886 states that the 30-day average should be a heat input average, so that emission rates
for low fuel burn and heat input are appropriately weighted with higher fuel burn and heat input.

Commenter 17772 recommends weighting the hourly values by flow rate. Commenter 17772 indicates
that low flow rates (flue gas) for startup should not carry the same weight as high flow rates for normal
operation. Commenter 17772 states that if there are short-term high emissions during shutdown, the
emission rate on subsequent days when the unit is not operating (and the emissions are zero, but are not
recorded because they are not measured during a "boiler operating day") will remain elevated, creating
additional days of apparent non-compliance.

Commenter 17820 suggests weighting the startup/shutdown emissions by adding the mass emissions for
each hour (lb/hr) for a total mass (lb) for the 30-day periods and dividing by the sum for each hour of the
heat input (mmBtu/hr) for a total heat input (mmBtu) for the 30-day period, resulting in a lb/mmBTU
30-day average that more accurately accounts for startup/shutdown with less impact for
startup/shutdown events.

Response to Comment 39: For periods of startup and shutdown, the EPA is finalizing work practice
standards instead of numeric emission limits. See the preamble for discussion.

2. Separate standards/work practice standards for SSM.

a. Support separate standards.

Comment 40: Several commenters (17730, 17886, 19120) state the EPA must establish emission
standards for startup/shutdown periods. Commenter 17740 states that if the EPA does not establish a 12-
month rolling average, the EPA should establish work practice standards for startup/shutdown periods.
Several commenters (17730, 17737, 17930) state the EPA must establish separate emission standards for

416


-------
startup/shutdown periods, or must extend the averaging time. Commenter 17677 states the EPA should
consider removing startup/shutdown data from the continuous compliance demonstration data, or allow
manufacturer's/site best work practices. Commenter 19122 recommends higher alternative PM limits or
a work practice standard.

Numerous commenters (16849, 17383, 17402, 17627, 17638, 17677, 17689, 17712, 17715, 17716,
17720, 17722, 17724, 17725, 17728, 17729, 17730, 17736, 17737, 17740, 17756, 17758, 17772, 17774,
17775, 17795, 17808, 17813, 17815, 17820, 17821, 17870, 17876, 17877, 17878, 17885, 17886, 17902,
17904, 17909, 17925, 17928, 17930, 18025, 18037, 18428, 18429, 18498, 18539, 19032, 19114, 19122,
18023) recommend work practice standards during periods of SS(M). Many commenters (17402, 17627,
17638, 17715, 17716, 17720, 17725, 17736, 17737, 17740, 17756, 17758, 17774, 17775, 17795, 17808,
17815, 17816, 17820, 17856, 17870, 17878, 17886, 17902, 17904, 17925, 17928, 17930, 18014, 18025,
18037, 18428, 18429, 18498, 18539, 18023) note that work practice standards are required in the Boiler
MACT rule; Multiple commenters (17383, 17689, 17712, 17724, 17740, 17757, 17758, 17774, 17813,
17876, 17885, 17909, 19032) state that previous (HAP) rulemakings required work practices for
startup/shutdown events. Commenters 17627 and 17816 state that the EPA determined in Boiler MACT
rule that MACT emissions limits do not apply to startup/shutdown. Commenter 17740 states the same
reasons that the EPA established work practice standards for startup/shutdown periods in Boiler MACT
apply here for EGUs, and the EPA offers unsupported assumptions as its only grounds for continuous
compliance with emission standards. Commenter 17758 notes the EPA provides no explanation or
justification why utility boilers are subject to more rigorous numeric standards. Commenters 17627 and
18037 note the EPA provides no compelling reason why MACT emission limits apply to EGU boilers
during startup/shutdown but not to other boilers and industrial furnaces. Commenter 17776 states the
EPA provides no reason for the different approach. Commenters (17878, 18428) state the EGU and
Boiler source categories are similar. Commenter 17930 states that work practice standards are more
appropriate for startup/shutdown.

Commenter 17623 states the EPA should propose a work practice standard during SSM periods
because: emission standards are not practicable; data collected during SSM periods are from CEMS but
do not include all pollutants regulated, particularly Hg from certain kinds of CEMS; and emission
standards are not economically practicable because collecting SSM period data would involve
significantly altering measurement techniques and may require manual monitoring.

Response to Comment 40: For periods of startup and shutdown, the EPA is finalizing work practice
standards instead of numeric emission limits. See the preamble for discussion. The EPA's rationale for
its approach to malfunctions is discussed in the preambles to the proposed rule and this final action See
also responses below that address the issue of determining compliance during malfunction events.

b. Sierra Club Decision.

Comment 41: Multiple commenters (16849, 17402, 17691, 17732, 17736, 17740, 17758, 17761, 17774,
17775, 17807, 17808, 17815, 17851, 17904, 17930, 19536/19537/19538) cite the Sierra Club court
decision that vacated SSM exemptions. Multiple commenters (17383, 17689, 17712, 17724, 17813,
17876, 17885) agree that court decisions indicate that HAP regulation must account for
startup/shutdown events.

Several commenters (17732, 17775, 17904, 17930) state that section 112 only requires that some section
112 compliant standard apply at all times. Several commenters (17732, 17775, 17930) state that section
112 does not require that one standard apply to all periods. Commenter 17772 states that the court case

417


-------
clarified that providing continuous emission reduction did not mean that a single standard for all periods
was required. Commenter 17930 does not support the Sierra Club decision, and states that it is clear that
the decision does not require one uniform standard at all times.

Commenter 17758 points out that the discussion of CAA section 112(h) in the Sierra Club decision and
the decision itself do not constrain the EPA's ability to choose work practice standards in lieu of
numeric standards. Commenter 17736 states that Sierra Club decision should not be treated as
authoritative or supportive of the EPA's action in this rulemaking, as Sierra Club only bars the EPA
from providing units with a blanket exemption, and the court did not hold that SSM periods must be
included in MACT standards.

Commenter 17761 states the SSM Exemption court case does not dictate the onerous and potentially
unachievable result set forth in the rule. Commenter 17904 states that the EPA has gone well beyond the
Sierra Club decision by not only providing no exclusions, but also failing to offer alternative provisions
addressing excess emissions during startup/shutdown. Commenter 17904 states that the EPA does not
explain why these periods cannot have alternative standards.

Commenter 18539 states that applying a different standard during SSM is consistent with section
112. Commenter 18539 states that the court has held that emissions standards could be different for
SSM and that work practice standards were permissible. Commenter 19121 states that CAA does not
allow exemptions for SSM.

Commenter 17758 states that EPA cited to Sierra Club v. EPA (551 F.3d 1019) in both the boiler MACT
and the EGU MACT and came to disparate conclusions that continuously applicable numeric standards
are required at all times. According to the commenter, the court did not find that numeric emission limits
under section 112(d) were required during SS periods. The commenter states that work practice
standards under section 112(h) would satisfy the requirements of Sierra Club and EPA can choose to use
work practice standard in lieu of numerical standards.

Response to Comment 41: For periods of startup and shutdown, the EPA is finalizing work practice
standards instead of numeric emission limits. See the preamble for discussion. The EPA's rationale for
its approach to malfunctions is discussed in the preambles to the proposed rule and this final action. As
explained in those preambles, the EPA has determined that CAA section 112 does not require that
emissions that occur during periods of malfunction be factored into development of CAA section 112
standards. As the EPA further explained, accounting for malfunctions would be difficult, if not
impossible, given the myriad different types of malfunctions that can occur across all sources in the
category and given the difficulties associated with predicting or accounting for the frequency, degree,
and duration of various malfunctions that might occur. Setting work practice standards under section
112 presents the same issues as setting numerical emission limits given the varied nature of
malfunctions.

c. CAA section 112(h).

Comment 42: Multiple commenters (17716, 17730, 17736, 17740, 17758, 17774, 17775, 17815, 17904,
18429, 18023) cite section 112(h) and state that section 112(h) allows work practice standards. Several
commenters (17740, 17774, 17775, 17815, 17904, 18023) note that emissions cannot be measured
during SSM, that it is not feasible to prescribe or enforce an emission standard, and refer to the 112(h)
CAA definition of the phrase "not feasible to prescribe or enforce" which includes any situation in
which the Administrator determines that the application of a measurement methodology to a particular

418


-------
class of sources is not practicable due to technological and economic limitations. Commenters (17716,
17720, 18023) state the EPA must provide a separate work practice standard for SSM because it is not
technically feasible to complete stack testing (and monitoring, 17720) during these periods.

Multiple commenters (17402, 17716, 17725, 17736, 17740, 17758, 17820, 17870, 17904, 17925, 18014,
18025, 18498, 18539, 18023) also point out that the EPA found in Boiler MACT that it is not
technically feasible to complete stack testing or monitor during startup and shutdown. Multiple
commenters (17402, 17716, 17725, 17740, 17904, 18037, 18539, 18023) state the same measurement
problems (and technological difficulties, 17740) exist for EGUs. Commenters 17740 and 17758 note
that Boiler MACT units and EGUs are substantially similar, and commenter 17740 states that the EPA
has recognized previously that ICI boilers and EGUs are virtually identical. Commenter 17740 notes
that the EPA attributes differences between ICI boilers and EGUs to size of units, boiler/furnace
technology, and portion of electrical output for sale, but none of these differences allow EGUs to
complete testing requirements during startup/shutdown periods. Commenter 17758 states that EGUs
have the same issues as ICI boilers with respect to emission testing.

Commenter 18037 states it is not feasible to obtain sufficient data for startup/shutdown. Commenters
17725 and 17904 state that no technical feasibility for stack testing and monitoring leaves the EPA and
the regulated community without a practical way to accurately determine emissions during
startup/shutdown. Commenter 18023 has evaluated stack testing times and relays that total PM testing
would require 8 to 10 hours and metal HAP and acid gas testing would require minimum of 16 hours.
Several commenters (17725, 17820, 18014, 18498) state it is uncertain whether representative
measurements could be obtained during startup/shutdown due to dynamic flue gas conditions and
technical limitations with measurement technology. Commenter 18023 states that startups are transient
periods where heat input, fuels, and gas flows continually change, and stack testing is impossible due to
load fluctuations. Commenter 17851 states that testing during transient conditions is
difficult. Commenter 17851 states that running EPA Reference Method 5 during startup would require 6
to 8 hours to complete a single test, but the conditions would have changed so significantly it would be
impossible to understand what the data meant or extrapolate the data. Commenter 17851 notes the same
is true for CEMS data during startup.

Response to Comment 42: For periods of startup and shutdown, the EPA is finalizing work practice
standards instead of numeric emission limits. See the preamble for discussion. The EPA's rationale for
its approach to malfunctions is discussed in the preambles to the proposed rule and this final action. As
explained in those preambles, the EPA has determined that CAA section 112 does not require that
emissions that occur during periods of malfunction be factored into development of CAA section 112
standards. As the EPA further explained, accounting for malfunctions would be difficult, if not
impossible, given the myriad different types of malfunctions that can occur across all sources in the
category and given the difficulties associated with predicting or accounting for the frequency, degree,
and duration of various malfunctions that might occur. Setting work practice standards under section
112 presents the same issues as setting numerical emission limits given the varied nature of
malfunctions. See also responses below that address the issue of determining compliance during
malfunction events.

d. Performance testing and measurement issues.

Comment 43: Commenter 18034 opposes any requirements to require stack testing during
startup/shutdown. Commenter 18034 states that requiring stack testing during potentially dangerous
plant operations that could place testing personnel at risk is inappropriate.

419


-------
Commenter 17815 states that during startup/shutdown, the EGU exit gas temperature and flow rate are
not at steady state, and it is impossible to collect condensable and filterable PM samples. Commenter
17815 states it is not reasonable to establish filterable PM as a surrogate with no reasonable ability to
measure. Commenter 17737 states there are significant challenges in collecting accurate emissions data
during startup (commenter cites UARG comments).

Commenter 17912 states that the EPA incorrectly assumed that measuring and monitoring equipment
will function properly under these conditions. Commenter 17912 states that the infeasibility of obtaining
valid stack tests under SSM means there is no way to provide assurance that a unit could achieve the
limits.

Commenter 18021 states that the EPA must account for SSM in the test protocols that influence
compliance.

Commenter 17736 states control device operating characteristics during full load testing is not
representative of the range of operating characteristics that a unit may experience on any given day.

Commenters 17725 and 17904 state that monitoring equipment cannot operate accurately during SSM
periods due to transient flow and flue gas conditions. Commenter 17725 states that since monitoring
data for SSM periods are not representative of normal operations and are of suspect quality, the EPA
should adopt an approach where they would not be included in data averages used to determine
compliance and missing data substitution procedures. Commenter 17725 recommends that the EPA
provide clarity in the rule for how such periods would be treated.

Response to Comment 43: CEMS data during startup and shutdown will not be used for purposes of
calculating 30-day averages under the final rule. For periods of startup and shutdown, the EPA is
finalizing work practice standards instead of numeric emission limits and thus commenters concerns
related to monitoring during such periods is moot. See the preamble for discussion.

For malfunction periods, the EPA does not agree with the commenters that CEMS will not provide data
during malfunction periods (unless the malfunction is related to the CEMS) and commenters provide no
support for their assertion that data cannot be obtained. To the extent an EGU owner or operator has not
installed CEMS or believes a CEMS reading during a malfunction event is in error (i.e., shows non-
compliance) over the averaging period the EGU owner or operator may use other available means
(including engineering judgment) or information to demonstrate that the source complied with the
standard.

e. Suggestions for work practice requirements.

Comment 44: Multiple commenters (17677, 17714, 17725, 17808, 17870, 17902, 17925, 17928,
18025) suggest that work practices should include or be based on manufacturer recommended practices.
Several commenters (17725, 17870, 18025) recommend that, as in Boiler MACT, the EPA require units
to follow manufacturer's specifications for minimizing emissions during startup/shutdown (as in 40 CFR
part 63.7530(h)). Commenter 18025 also suggests that rather than referring to "manufacturer's
recommended procedures", the EPA could refer to standard industry procedures to account for instances
where more than one manufacturer has supplied different components. Commenter 17772 suggests the
work practice standard take into account the boiler configuration, boiler type, and safe operation of the
unit. Several commenters (17725, 17774, 19032) state the work practice standard should account for

420


-------
boiler type and control equipment. Commenter 17816 states that work practices should be specific to a
unit's boiler type, operational characteristics, and APCDs.

Commenter 17774 states that sources should have to address malfunctions as soon as safely practicable.
Commenter 17774 states facilities have large incentives to address malfunctions that may lead to excess
emissions since facilities have emission limits under a number of EPA programs.

Commenter 17174 states the EPA should explain the reasoning for not requiring SSM plans. Commenter
18037 recommends a SSM plan be included in the Title V permit as an appropriate work practice
standard. Commenter 17691 suggests the EPA should require startup/shutdown plans, for consistency
with the recent Boiler MACT standard, since startup/shutdown events are predictable and routine.

Response to Comment 44: For periods of startup and shutdown, the EPA is finalizing work practice
standards instead of numeric emission limits. See the preamble for discussion. The EPA's rationale for
its approach to malfunctions is discussed in the preambles to the proposed rule and this final action. The
EPA is setting standards that apply at all times, including periods of startup and shutdown and periods of
malfunction. With such standards in place, sources have ample incentive to plan for and achieve
compliance during startup and shutdown and during malfunctions, so there is no longer any reason to
require sources to develop SSM plans

f. Operating parameters for APCD.

Comment 45: Several commenters (17820, 17821, 17868) state that work practices should be
established in lieu of operating parameters for APCDs. Commenters 17821 and 17868 state that the EPA
has no basis to expect that operating parameter limits established during performance tests will be
achievable during SSM. Commenter 17821 states that the EPA established enforceable operating
parameters in Boiler MACT but made it clear that those limits do not apply during SSM. Commenter
17820 states that operating limits for operating parameters for APCD should not apply during
startup/shutdown. Commenters 17820 and 17868 state that the EPA requires sources to establish control
device operating parameter levels that are dependent upon load during periods of "maximum normal
operating load," or other frequently used loads, and then maintain those levels during other periods,
including startup and shutdown.

Several commenters (17820, 17821, 17868) state that the EPA assumptions regarding startup/shutdown
are not applicable to APCD operating parameter limits, which are based on 12-hr averages established
during the performance test (maximum normal operating load) and not based on startup/shutdown.
Commenter 17820 states that startups on large units take longer than 12 hours, so there is no allowance
for periods of startup/shutdown in the parameter operating limit.

Response to Comment 45: The final rule does not provide for operating parameter limits for air
pollution control devices. Please see the final preamble and responses to comments under Comment
Code 5A05. For periods of startup and shutdown, the EPA is finalizing work practice standards instead
of numeric emission limits. See the preamble for discussion. The EPA's rationale for its approach to
malfunctions is discussed in the preambles to the proposed rule and this final action.

3. Other averaging periods.

a. General.

421


-------
Comment 46: Commenter 17774 recommends a longer compliance period to provide flexibility and
accommodate SSM events. Commenter 16849 suggests a longer averaging period, as an alternative to
not including SSM hours in the 30-day average. Commenters (17737, 17740, 17795, 17904, 17930,
19122) recommend the EPA establish a 12-month rolling average or annual average. Commenter 17772
recommends moving to a 90-day or longer boiler operating day average.

Commenter 17730 states the EPA must establish separate emission standards for startup/shutdown
periods, or must extend the averaging time.

Commenter 17737 states that if the EPA does not establish a work practice standard, then the EPA
should use a 12-month rolling average (17737, 19032), or modify the 30-day rolling average by
establishing a minimum number of hours to qualify as a boiler operating day and averaging all hours
within the 30 boiler operating days (17737).

Commenter 17930 states that if a work practice is not implemented, the EPA should extend the
averaging period to annual averaging and increase the emissions limit for all pollutants to better account
for SSM emissions.

Commenter 17740 states that because the EPA is including emissions from non-steady state operations,
including SSM and load following operations, the averaging period should be lengthened to a 12-month
rolling average, calculated monthly. Commenter 17740 states that especially for single units that cannot
be part of a multi-unit plant's averaging plan, the averaging period is highly important in dealing with
these non-steady state events. Commenter 17740 notes that a 12-month rolling average for all HAP
would achieve environmental protection yet provide needed operational flexibility and accommodate
real-world operating conditions. Commenter 17795 states that a 12-month averaging period would
ensure operational flexibility, allowing economic consideration to be part of dispatching and operating
decisions.

Commenter 17795 states that there is no logical reason for providing more flexibility for facilities
averaging multiple units than for facilities with a single unit or common stack.

Commenter 17761 states the EPA should extend the averaging period to account for routine and
required maintenance, such as the required shutdown and startup required to inspect burners under this
rule. Commenter 17761 states that the burner inspection outage time alone, along with required
adjustments or repairs, could cause a facility to exceed the 30 boiler operating day average emission
limit, particularly since there is both a shutdown and startup. Commenter 17761 states that to comply,
facilities will have to take outage both to install controls and to perform assessments required by the
rule, so that facilities may be forced into a situation that upon startup they are out of compliance.

Commenter 17774 states the EPA should lengthen the averaging period to provide needed flexibility to
accommodate the range of operating events, including SSM events. Commenter 17761 notes that longer
averaging periods for all emissions limits (such as an annual or semi-annual average) to fully account for
the emission variability during these startup and shutdown periods are consistent with the holding in
Sierra Club as emissions limits would continue to apply to facilities at all times.

Response to Comment 46: For periods of startup and shutdown, the EPA is finalizing work practice
standards instead of numeric emission limits. See the preamble for discussion. The EPA's rationale for
its approach to malfunctions is discussed in the preambles to the proposed rule and this final action. As
explained in those preambles, the EPA has determined that CAA section 112 does not require that

422


-------
emissions that occur during periods of malfunction be factored into development of CAA section 112
standards and thus we are not revising the averaging time in the final rule to account for malfunction
emissions. We believe that the 30 day averaging period provides the appropriate level of flexibility for
the regulated industry and that longer averaging periods would inappropriately weaken the standards and
limit our ability to evaluate source compliance on an ongoing basis (see RTI memorandum). In addition,
the commenters' expressed concern about including startup and shutdown period in the averaging is no
longer relevant in light of the inclusion of work practice standards for such periods in the final rule.

b. Kushner letter.

Comment 47: Commenter 17761 states that there is precedent in the Kushner Letter that the agency
would provide compliance flexibility to sources that implemented appropriate responses (i.e., good faith
efforts) to SSM events and would provide longer averaging periods (annual or semi-annual) (EPA
Office of Civil Enforcement Interpretative Letter from Director Adam Kushner, July 22, 2009).

Commenter 17904 cites the Kushner Letter and requests that the EPA be consistent with the guidance in
the letter, by averaging over a long period of time, e.g., yearly.

Response to Comment 47: For periods of startup and shutdown, the EPA is finalizing work practice
standards instead of numeric emission limits. For malfunctions, the EPA is finalizing the proposed
affirmative defense language for exceedances of the numerical emission limits that are caused by
malfunctions. See the preamble for discussion.

The Kushner letter did not state that EPA would necessarily provide longer averaging periods in
promulgating new standards. In assessing the immediate impact of the Sierra Club v. EPA decision, the
Kushner Letter merely noted that many sources may not have difficulty complying with existing
standards during periods of SSM even if they lost the SSM exemption because of averaging periods built
into those rules.

4. Diluent capping and electrical production.

Comment 48: Commenter 17648 agrees with the options for calculating input-based emissions based
upon a default diluent value or fuel specific CO2 concentration, or calculating output-based emissions
using an electrical production rate of 5 percent of rated capacity during startup/shutdown periods.

Commenter 17767 supports use of minimum default values for the diluent and power generation
numbers for startup/shutdown for parameters monitored by CEMS and by Low Emitting EGU
methodology.

Commenter 17923 recommends the rule allow for alternative unit specific lb/MWh emission
calculations, given that the 5 percent of rate capacity value could potentially cause overestimates
resulting in artificial compliance issues.

Commenter 17821 states the EPA should define the default CO2 value for various fuel types, just as it
has for O2. Commenter 17821 urges the EPA to define a default CO2 value of 5 percent for coal-fired
boilers for startup/shutdown, and the EPA should not leave it up to the regulated community as no two
companies would choose the same value and lead to discrepancies. Commenter 17715 states that diluent
capping during startup/shutdown periods is appropriate. Commenter 17715 recommends including a
table in the rule listing the appropriate CO2 diluent values, notes that the O2 diluent value is not

423


-------
appropriate, and recommends use of the diluent cap values already defined in part 72 of 5 percent for
C02 and 14 percent for 02 for coal-fired EGUs, which would harmonize the two rules and provide
adequate margin in the data. Commenter 17821 also supports a value of 5 percent C02, consistent with
part 75. Commenter 17715 states the equivalent values for reporting lb/MWe are too low and should be
changed to 10 percent.

Commenter 17904 states that startup/shutdown emissions cannot be confirmed by standard methods.
Commenter 17904 states that the EPA recognizes measuring and monitoring during startup/shutdown is
problematic. Commenter 17904 states that the EPA ignores the fact that there are no appropriate
methods for accurately determining a representative value for pollutant concentrations. Commenter
17904 notes that the inclusion of diluent values in a 30-day compliance period would appear to disregard
both measurement inaccuracies and variability of pollutant concentrations.

Several commenters (19536, 19537, 19538) state that no compliance monitoring is required during
SSM. The commenters state that the monitoring provisions do not require any testing during periods of
startup, shutdown, and malfunction and thus provide no means to determine if the standards are met
during these periods. The commenters state that the default diluent value or the corresponding fuel
specific CO2 concentration for use in calculating emissions in units of lb/MMBtu or lb/TBtu during
startup/shutdown periods does not assure continuous compliance during these periods. Commenters state
that because no testing is required during SSM periods, even assuming the diluent requirement would
address SSM, it would never have to be used as no SSM testing is required.

Comment 49: Commenter 17801 suggests wording changes for the electrical output to be applied
during startup/shutdown to reflect when electric production actually exceeds 5 percent of the rated
capacity, so that the default use does not result in an underestimate of power generated and overestimate
of output-based emissions: For calculating emissions in units of lb/MWh or lb/GWh only during startup
or shutdown periods, use a nominal electrical production rate of equal to 5 percent of rated capacity until
the measured electrical production rate exceeds 5 percent of rated capacity.

Several commenters (17740, 17758, 17776) state that the EPA does not address these concerns (that
there are equipment integrity concerns, technological limitations, economical issues, and safety issues])
but accounts for variable conditions by using a default value and specifying electrical production rate;
by proposing these default values and production rates, the EPA acknowledges that it is not feasible to
test and monitor emissions from EGUs during startup/shutdown. Commenter 17821 states that use of
default values (10%) only addresses the limitation of the equations when using CEMS, it does not
address that the emissions themselves are different during startup/shutdown. Multiple commenters
(17758, 17776, 17912, 19536, 19537, 19538) state that the EPA does not explain how the default values
were selected or why they are appropriate and accurate proxies for emissions during SS(M). Commenter
17925 does not understand how the EPA determined these parameters.

Response to Comments 48 - 49: For periods of startup and shutdown, the EPA is finalizing work
practice standards instead of numeric emission limits. See the preamble for discussion. The EPA's
rationale for its approach to malfunctions is discussed in the preambles to the proposed rule and this
final action. We agree with the commenters that the rule does not require formal performance testing
during SSM periods. However, as noted above, we believe that it is important to collect data during all
periods including SSM periods, as the rule requires when conducting any continuous monitoring.

Sources who install CEMS or other continuous monitoring devices are required to operate the
monitoring equipment and collect data at all timesthe process unit is operating and at the intervals
specified in the rule, except for periods of monitoring system malfunctions, repairs associated with

424


-------
monitoring system malfunctions, required monitoring system quality assurance or quality control
activities and any scheduled maintenance as defined in the unit's site-specific monitoring plan. Sources
who conduct continuous monitoring will have HAP and other emissions data during SSM periods.
Sources who opt to conduct periodic testing will not have data collected during malfunction periods. A
source who experiences a malfunction event may use any available information to demonstrate that the
source complied with the standard notwithstanding the malfunction.

5.	Reliability issues.

Comment 50: Commenters 16849 and 18023 state that including SSM periods in the rule will cause
reliability issues. Commenter 18023 states the ability to startup and shutdown units in a flexible manner
and bypass controls for short periods are critical to operating a reliable electric system. Commenter
18023 states the rule does not provide regulatory relief during modes of operation such as SSM that are
likely to result in higher emission rates, this will prohibit APCD bypass, and units will have to shut
down if not able to meet MACT rule standard at all times. Commenter 18023 indicates that this will
cause reliability challenges and will force additional shutdowns and restarts. Commenter 18023 notes
there are additional reliability challenges for facilities that have multiple units served by a single APCD.
Maintenance outages are scheduled for planned outages at one or more units; however Commenter
18023 states that transmission requirements may demand a certain amount of generation from that plant
that could oblige the remaining units to operate while the control is offline. Commenter 18023 states the
prohibition of emissions bypass under even these special circumstances could result in transmission
consequences for areas served.

Commenter 17902 states the need for EGUs to provide uninterrupted reliable power is contrary to
maintaining operations with frequent malfunction.

Response to Comment 50: For periods of startup and shutdown, the EPA is finalizing work practice
standards instead of numeric emission limits. These work practice standards take into account operation
of APCDs. See the preamble for discussion. Given the inclusion of the work practice for startup and
shutdown periods, we believe those comments are now resolved as they relate to startup and shutdown
periods.

Concerning malfunction, we question the scope of this problem notwithstanding commenters assertions.
Commenters have not provided information on the scope of this alleged problem or the likelihood that
sources would have the large number of malfunction events that commenters describe. As stated in
response to other reliability related comments, we believe we have identified mechanisms to address
reliability issues associated with implementation of this final rule.

We address APCD maintenance, bypass stacks, our approach to malfunctions, and reliability issues
elsewhere in the final rule record.

6.	Malfunctions.

a. Support or oppose malfunction approach.

Comment 51: Several commenters (17772, 17807, 17902, 18428) support the malfunction exclusion.
Commenter 17648 states that the EPA decision not to include malfunctions is reasonable, aligns with
purpose of section 112, and malfunctions do not reflect normal variability in operating conditions.
Commenter 17648 states the EPA already accounted for variability for typical operating conditions and

425


-------
it should not make further accommodations for malfunctions. Commenter 17772 also states they would
support some alternative standard that is based on real data that recognized emissions are higher during
malfunctions.

Commenter 17774 notes that the EPA's decision not to differentiate malfunction periods is not based on
any data. Commenter 17774 notes the EPA's reference to the precedent that standards that factor in the
variability of emissions under all operating conditions are reasonable. Commenter 17774 went on to
state that in this case, it would be both reasonable and appropriate for the EPA to based the MACT
standard on data that includes malfunctions. Commenter 17774 states that if the EPA chooses not to
include such malfunction data, it cannot expect sources to comply with general emission limits during
malfunction periods.

Commenter 17730 states that if malfunctions are included in the compliance calculation, the emission
standards should be raised to account for the variability or the averaging times should be lengthened to
account for including malfunction emissions.

Commenter 17767 disagrees with the EPA's statement that malfunction events are unlikely to lead to
noncompliance.Commenter 17730 states malfunction events will cause sources to violate the standard.
Commenter 17775 states that because the EPA does not factor malfunctions (even malfunctions of "best
performing" sources) into its proposed standards, it is unlikely the standards will be achievable if a
significant malfunction occurs. Commenter 17775 agrees with the EPA that equipment can and will fail
unexpectedly, and that some allowance must be made for periods of malfunction. Commenters 17821
and 17877 state that even the best performing units or technology will occasionally fail (and
malfunction). Commenter 17851 states that even the best operated and maintained facilities will have
malfunctions. Commenter 17623 states that malfunctions leave the source with uncertainty about
whether they will be penalized and vulnerable to citizen suits. Commenters (17623, 17821) appreciate
that the EPA states that not all malfunctions will result in violation; Commenter 17821 states that
sources are subject to the discretion of the EPA, state, and plaintiffs in citizen suits, and Commenter
17623 states that regulated sources are still subject to significant EPA and state discretion concerning
such occurrences and hold the burden of proving an affirmative defense.

Commenters 17623 and 17774 state the EPA should not be able to set a MACT floor that does not
account for malfunctions because it deems the data infeasible, while at the same time require compliance
with the strict standard during malfunction periods. Commenters note that just because the EPA is not
required to account for every conceivable malfunction does not mean it can set standards excluding data
of any malfunction event.

Commenter 17775 states the application of numerical limits to such malfunctions without a defense to
penalties clearly would violate the Due Process Clause and the Eighth Amendment prohibition on Cruel
and Unusual Punishment. Although Commenter 17775 appreciates the EPA's willingness to exercise
enforcement discretion and to provide a defense to civil penalties, the EPA's refusal to take
malfunctions into account when setting standards is not reasonable.

Several commenters (17808, 17870, 18025) recommend the EPA or states maintain current enforcement
discretion to address situations when a source fails to comply with a section 112(d) standard as the result
of a malfunction. On the other hand, Commenter 17402 opposes the EPA's proposal to use its discretion
to determine an appropriate response to malfunction events and it opposes EPA's affirmative defense
proposal. The commenter has established a state-approved plan that it follows during malfunctions and
breakdowns. The commenter believes this approach is preferable to EPA's proposal, in which there is a

426


-------
presumption of non-compliance. The plan incorporated in commenter's Title V operating permit
application ensures that future malfunction events will be minimized and that best practices will be
followed, whereas EPA's proposed approach is focused on after-the-fact penalty.

Response to Comment 51: The EPA's rationale for its approach to malfunctions is discussed in the
preambles to the proposed rule and this final action. As explained in more detail in the preamble, EPA's
approach to malfunctions is consistent with CAA section 112 and is a reasonable interpretation of the
statute. While the EPA recognizes that malfunction events may lead to noncompliance, the EPA
disagrees with commenter's statements concerning enforcement discretion. The EPA will consider the
totality of circumstances of each case in determining whether and to what extent and enforcement
response is appropriate. The commenter's suggestion that its state-approved plan is prefereable to the
EPA's approach does not explain how an approach based on such a plan meets the requirements of
section 112.

b. Work practice specific to malfunctions/Sierra Club Decision.

Comment 52: Commenters 17775 and 18023 suggest the EPA work with utilities to develop reasonable
work practice standards under section 112(h) that take malfunctions into consideration. Commenter
17623 states the best approach is to require a work practice standard that ensures malfunction problems
are addressed as soon as safely practicable.

Commenter 17775 states section 112 does not limit the EPA's standard setting obligation to "distinct
operating modes." The commenter notes that as the D.C. Circuit ruled in Sierra Club v. EPA, CAA §
112 requires that some "section 112-compliant standard" apply at all times (not just during distinct
operating modes). 551 F.3d 1019, 1027 (D.C. Cir. 2008). The commenter states that if the EPA has
determined that it is not technologically or economically "feasible" to gather emissions data necessary to
establish numerical emissions standards that "take malfunctions into account," the EPA should
promulgate operational and work practice standards as section 112(h) specifies. To the extent the EPA is
attempting to distinguish between the "impracticality" of taking malfunctions into account, and the
"infeasibility" of prescribing and enforcing standards for such events, the commenter states that the
EPA's position is difficult to square with the CAA.

Commenter 17775 states that specifying work practice standards for malfunctions is more consistent
with the CAA, and the D.C. Circuit's interpretation of it in Sierra Club, than the EPA's proposed
affirmative defense. Although the court found that the existing "general duty to minimize emissions"
was not sufficient to qualify as a section 112(d) standard, and that the EPA had "not purported to act
under section 112(h)," the commenter states that it also made clear that the CAA does not require that
the same standard apply to all periods. Id. at 1021 (recognizing that "continuous" under CAA § 302(k)
does not mean "unchanging"), 1028. In short, the commenter states that nothing prohibits the EPA from
establishing section 112(h) standards for periods that include a malfunction, even if section 112(d)
standards apply at other times. In fact, the commenter states that establishing section 112(h) standards
for malfunctions would be more consistent with the Sierra Club ruling than applying clearly
unachievable standards and allowing a defense to penalties, since an unachievable section 112 standard
is not "section 112-compliant." The commenter notes that it also would be more consistent with
Congressional intent. By allowing work practice and other requirements under section 112(h), the
commenter states that Congress clearly intended that sources be provided the opportunity to be fully in
compliance with some standard at all times. The commenter states that nothing in section 112 suggests
that Congress intended to require a source owner or operator to certify "violation" of a section 112
standard as a result of an event the source could not reasonably control. The commenter states that the

427


-------
EPA should adhere to that intent and specify reasonable work practice or operational requirements for
periods of malfunctions.

Response to Comment 52: The EPA's rationale for its approach to malfunctions is discussed in the
preambles to the proposed rule and this final action. The EPA's rationale does not turn on whether
malfunctions should be viewed as a distinct operating mode. Further, the EPA's rationale for its
approach to malfunctions is not based on the criteria that must be met to justify a finding that it is not
feasible to prescribe or enforce an emission standard under section under section 112(h). Section 112 (h)
(2) provides that such a finding must be based on a determination that "a hazardous air pollutant or
pollutants cannot be emitted through a conveyance designed and constructed to emit or capture such
pollutant, or that any requirement for, or use of, such a conveyance would be inconsistent with any
Federal, State or local law" or "the application of measurement methodology to a particular class of
sources is not practicable due to technological and economic limitations." The EPA justification for its
approach to malfunctions is unrelated to the findings required under section 112(h)(2). Thus,
commenters' claim that the EPA's attempt to distinguish between the two "is difficult to square with the
CAA" is without merit. As explained in the preamble to the proposed rule and this final rule, the EPA
has determined that CAA section 112 does not require that emissions that occur during periods of
malfunction be factored into development of CAA section 112 standards. The EPA has further explained
its view that accounting for malfunctions would be difficult, if not impossible given the myriad different
types of malfunctions that can occur across all sources in the category. This rationale is not based on the
factors set forth in section 112(h)(2).

c. Reporting.

Comment 53: Commenter 17775 states that the EPA's reporting requirements also raise some practical
issues. Although some malfunctions will occur even at the best performing plants, the commenter states
not all malfunctions will necessarily result in emissions above a numerical standard. With the longer
averaging times the EPA has proposed, the commenter states that it is possible that elevated emissions
from some malfunctions will be sufficiently compensated for during normal operation such that they do
not result in exceedance of a 30-day rolling average. The commenter indicates that determining before
the end of a 30-day period whether a malfunction will result in an exceedance of a 30-day rolling
average may not always be easy. Commenter 17775 states that requiring EGUs to keep logs of
malfunctions is not unreasonable, however, requiring notice to the EPA of events before the EGU even
knows whether an exceedance will occur, requiring logs in response to exceedances (rather than
malfunctions), or requiring that the exceedance occur at the same time as the malfunction, are not
reasonable. Commenter 17775 suggests that the EPA rework its proposal to recognize that some
malfunctions that ultimately result in exceedance of an emission limit (particularly those with longer
averaging times) may occur long before the exceedance is recorded. The commenter notes that the EPA
should simply require the maintenance of the appropriate records surrounding any event identified by
the EGU as a malfunction and leave the reporting until after all of the data relevant to the compliance
determination for the affected period are collected.

Commenter 17772 indicates that 40 CFR part 60 subpart Da rule and others exclude malfunction periods
from 30-day averaging.

Response to Comment 53: The EPA's rationale for its approach to malfunctions is discussed in the
preambles to the proposed rule and this final action. See preamble and rule for discussion on related
reporting requirements.

428


-------
The commenters appear to be referring to reporting associated with the assertion of an affirmative
defense, described in section 63.10001. The EPA agrees that the notice requirement associated with the
affirmative defense may not be practical when a 30-day averaging period applies. The EPA is revising
the notification requirement so that it reads " The owner or operator of the affected source experiencing
an exceedance of its emission limit(s) during a malfunction shall notify the Administrator by telephone
or facsimile (FAX) transmission as soon as possible, but no later than two business days after the initial
occurrence of the malfunction or, if it is not possible to determine within two business days whether the
malfunction caused or contributed to an exceedance, no later than two business days after the owner or
operator knew or should have known that the malfunction caused or contributed to an exceedance, but,
in no event later than two business days after the end of the averaging period, if it wishes to avail itself
of an affirmative defense to civil penalties for that malfunction."

d. Malfunction definitions.

Comment 54: Commenter 17775 notes that section 63.10005(a) makes a number of references to
"excess emissions" however, there is no general definition of "excess emissions" in section 63.2.
Commenter 17775 states that according to section 63.10(c)(7) and (8), "excess emissions" are supposed
to be defined in the applicable subpart, but proposed subpart UUUUU contains no such definition.
Commenter 17775 suggests the EPA issue a proposal to define "excess emissions" in the context of any
final rule that uses the term.

Commenter 17736 notes that the definition of "malfunction" is sufficient for the Utility MACT rule.

Response to Comment 54: We disagree with the commenter. In defining the standard, we are in effect
also defining emissions that are in excess of the standard. We have in this final rule established
numerical emission standards that must be met on a 30-day rolling average. Emissions in excess of those
levels over the established averaging period are considered excess emissions.

7. Affirmative defense.

a. Support or oppose AD approach.

Comment 55: Multiple commenters (17623, 17715, 17740, 17807, 17904, 17909, 17912, 18025, 18428,
19114) support affirmative defense (AD) for malfunctions; commenter 17722 generally supports the AD
for excess emissions. Multiple commenters (17689, 17724, 17712, 17876, 17877, 17885, 19032) support
affirmative defense concept but believe the EPA should articulate specific reasonable provisions in the
rule.

Commenter 17975 states that requiring agencies to evaluate and rebut AD on a case-by-case basis is
impractical and ineffective. Commenters (17689, 17712, 17877, 17885) state the EPA should not decide
the appropriateness of individual situation retroactivity on a case-by-case basis based on vague changing
guidelines. Commenter 17909 states the EPA should provide detailed guidance on how the provisions
will be applied and rely on case-by-case review. Commenter 17912 notes that the EPA properly
proposes flexibility for malfunctions. Commenter 17912 supports the EPA finding that it is reasonable
not to account for malfunctions in emission standards.

Commenter 17902 states that short of excluding malfunctions, they support AD, however, the EPA
should make it less burdensome. Commenter 17902 recommends the EPA remove items 7 through 9,
because the information is redundant with items 1 through 6, are unnecessary, are not reasonably

429


-------
documented or quantified, are not expected to provide meaningful insights on how to avoid future
malfunctions, and make the rule less impractical.

Commenter 17851 supports maintaining a regulatory provision for malfunctions, such as an AD.
Commenter 17851 notes concerns that the AD implies the facility is guilty until proven innocent.
Commenter 17851 states concerns that in calling it an AD even before it has been established to be a
deviation, improperly shifts the burden to the facility. Commenter 17851 suggests the EPA establish a
rebuttable presumption, rather than AD, where it is presumed the facility did everything in their power
to minimize emissions, unless the EPA proves certain facts that are enumerated in rules. Commenter
17851 states the burden of proof would be on the EPA.

Commenter 18500 states that the steps associated with AD are highly prescriptive and infer that the
failure to meet any step is a willful violation. Commenter 18500 states the standard should be moderated
to match the risk to the violation, and to recognize that malfunctions are unanticipated failures.

Commenter 17730 states that AD still requires the source to document the event and defend itself to the
EPA or in a court of law for violation of standard that was unreasonably established. Commenter 17402
recommends a SSM work practice plan in the Title V permit to minimize future malfunctions and ensure
best practices are followed, similar to the malfunction and breakdown plan they developed for their title
V application. Commenter 17902 states that EGUs are already required to minimize emissions during
SSM under title V operating permit conditions. Commenter 18447 states that the [AD] response to a
malfunction is heavy-handed and threatening. Commenter 18447 states that facilities are guilty until
they go to great lengths to prove innocence. Commenter 18447 states that the EPA would do well to
realize that even well-trained and well-intentioned employees can and do make mistakes.

Commenters 17402 and 17772 oppose the EPA's AD proposal for malfunctions. Commenter 17772
states that AD for malfunctions is inappropriate, overly complex, and unduly burdens both industry and
the EPA. Commenter 17772 states that the EPA has improperly shifted the burden of proof to the
facility, but the ultimate burden of proof to justify a civil penalty remains with the EPA, and the EPA
should have to present clear evidence sufficient to persuade a judge or independent fact finder that the
claimed malfunction should be disregarded for reasons such as poor maintenance, careless operation, or
other preventable conditions. Commenter 17772 states the multi-part process for establishing the
existence of a malfunction is overly complex and burdensome. Commenter 17772 suggests that any AD
to be used should be limited to the definition in section 60.4IDa. Commenter 17772 notes that the rule
establishes 12 separate requirements and requires the EGU operator to carry a burden of proof for each
one to comply; this is arbitrary and capricious. Commenter 17772 states that the 12 requirements are
vaguely worded and will themselves become a primary focus of litigation; after a malfunction occurs, it
is almost always possible for someone to allege there was some practice that could have been employed
to prevent the malfunction.

Commenter 17772 also states their concerns that root cause analysis in section 63.10001(a)(9) will be
used against the EGU operator, since a potential argument may be made that earlier implementation of
the recommended correction would have prevented the malfunction. Commenter 17772 states that
proposed rule section 63.10001(a)(5), for example, states that the accused must prove that "all possible
steps were taken" to minimize the impact of the excess emissions. The commenter asks whether that
means that if the EPA or some private litigate can imaginatively identify some step not tried, then the
affirmative defense is rejected? The commenter goes on to note that if so, no affirmative defense would
ever be successful — some untried alternative or additional action could always be found by inventive
counsel or expert witness. Similarly, commenter 17772 notes that proposed rule section

430


-------
63.10001 (a)(i)(2) states that the excess emissions "Could not have been prevented through ... better
operation and maintenance practices." The commenter indicates this could be an impossible standard to
meet if "better" is used to mean better than the practices actually employed by the accused. Commenter
17772 states that this vague and unworkable standard should, at a minimum, be modified to allow the
accused to meet whatever burden of presentment or proof is applied by a showing that the operation and
maintenance practices were consistent with good utility practice.

Commenter 17851 states the requirements in section 63.10001 are impossible to meet due to ambiguous
terms such as "careful," "proper," or "better", and these terms must be defined in order to determine
whether the criteria were met. Commenter 17851 states the EPA should drop references to "any" activity
and "all" in this paragraph.

Commenter 17912 states that the AD is restrictive and vague. Commenter 17912 urges the EPA to set
conditions for AD that a facility can actually achieve rather than setting a virtually insurmountable bar.

Commenter 17736 objects to the EPA's attempt to restrict the definition of "malfunction" such that the
concept is eliminated albeit the EPA's proposed "affirmative defense." Commenter 17736 notes that
determining whether no malfunction occurred if it "could have been prevented through careful planning,
proper design, or better operation and maintenance," the EPA should explain what "proper design" and
"better operation" is.

Commenter 17775 cites concerns regarding AD. Commenter 17775 states that section 63.10005(a)(l)(i)
refers to an "unavoidable" failure, and although the difference between "reasonably preventable" and
"unavoidable" may seem small, the EPA's rule seems to require a stronger showing than the definition
anticipates in that it leaves room to argue whether a failure could have been prevented even if the acts
necessary to do so were "unreasonable." Commenter 17775 indicates that other provisions in (a)(1),
paragraph (ii) ("[cjould not have been prevented"), (iii) ("could [not] have been foreseen and avoided, or
planned for"), and (a)(5) ("all possible steps") - also seem to remove the requirement of
"reasonableness." In contrast, the commenter notes that other provisions include references to
practicability. At a minimum, Commenter 17775 states the EPA must revise its criteria consistent with
the section 63.2 definition to include the concept of "reasonableness."

Several commenters (17383, 17712, 17876) state AD for malfunctions should be reasonable and the
requirements well articulated. With respect to AD for malfunctions, Commenter 18023 requests that the
EPA reconsider the criteria defining malfunctions to include the concept of "reasonableness" and to
defer reporting until an exceedance has been recorded.

Commenter 17722 states that for language in section 63.10001(a)(5) "All possible steps were taken..." it
should be clarified that those steps must be relevant to the excess emissions. The commenter also stated
the term "possible" is subjective and could be replaced by "all steps needed, based on best professional
judgment."

Commenter 17722 states that for language in section 63.10001(a)(9), it should be clarified that written
root cause analysis should include all forms of documentation, including electronic records.

Commenter 17975 states that neither NSPS nor MACT standards appropriately deal with malfunction.
Commenter 17975 states that the EPA must determine whether certain emission control technologies are
less likely to malfunction and cause standards to be exceeded. Commenter 17975 states that if these

431


-------
technologies are available, the EPA should not provide an AD for malfunctions from emissions controls
that are accident prone.

Several commenters (19536, 19537, 19538) state that the EPA'S AD for malfunctions is unlawful.
Commenters state that the CAA makes clear how the courts are to assess civil penalties, whether a case
is brought by the EPA or a citizen. 42 U.S.C. § 7413(e). The commenters note that Congress intended
citizens to be able to enforce emission standards under the CAA using the full range of civil
enforcement mechanisms available to the government, and, in the HAP context, subject only to the
limitation that government not be "diligently prosecuting" its own civil enforcement action, CAA §
304(b)(1)(B), 42 U.S.C. § 7604(b)(1)(B). The commenters state that the EPA's rule proposal, by shifting
this careful balance and contravening these mandates, violates the CAA.

Commenters state that the AD that the EPA proposes to allow in case of malfunctions goes directly
against congressional intent in two ways. First, the commenters note that Congress expressed a clear
intent as to how judges should determine the size of civil penalties whenever they are sought and thus
Congress flatly barred the EPA from limiting when civil penalties can be assessed. See Chevron, U.S.A.,
Inc. v. Natural Res. Def. Council, Inc., 467 U.S. 837, 842-43 (1984). In this proposal, the commenters
note that the EPA acts outside of its delegated authority to limit civil penalties available in citizen suits
or its own enforcement actions. Second, the commenters state that the proposal will impermissibly chill
citizen participation, and the ability to win an effective, deterrent remedy, in CAA enforcement actions.

Commenters state that the AD is fatally flawed because the EPA cannot decide when civil penalties will
not be allowed. The commenters state that the CAA itself spells out the only limits that Congress
intended to impose on citizens' ability to seek and recover penalties in enforcement suits under CAA §
304, 42 U.S.C. § 7604. See 42 U.S.C. § 7413(e). By attempting to impose additional agency-created
limits, the commenters state that the EPA exceeds its authority. The commenters note that Congressional
intent on civil penalties is clear-they are a remedy available to citizen plaintiffs, and the CAA gives
judges a list of factors to consider in assessing them. As such, the commenters state the EPA cannot
interpret the statute to contravene that intent, and by attempting to rewrite this provision, via regulation,
the EPA has done just that.

Commenters state that the CAA grants the EPA minimal discretion that only applies to administrative
penalties, allowing the EPA to "compromise, modify, or remit, with or without conditions, any
administrative penalty which may be imposed under [subsection 113(d)]." 42 U.S.C. § 7413(d)(2)(B).
However, the commenters state there is no similar grant of authority to the EPA to compromise, modify
or limit civil penalties that a court may impose under section 113(e) or section 304. The commenters
state that section 304(a), 42 U.S.C. § 7604(a), grants courts the sole authority "to apply appropriate civil
penalties" in citizen suits. The commenters note that the explicit reference to the EPA's ability to modify
penalties in one subsection and its absence in the other subsection of the same provision can only be
understood as an intentional decision by Congress that the EPA cannot contravene by rule.

Commenters state that citizen participation in CAA enforcement also will be hampered, in violation of
citizens' rights to protect themselves from pollution and in direct conflict with congressional intent. The
commenters state that the affirmative defense would likely be used on a routine basis by polluters
seeking to avoid penalties, just as the malfunction exemption was. As a result, the commenters note that
citizens who seek civil penalties against polluters in order to protect themselves and achieve the CAA's
goals may be forced to engage in fact intensive disputes over the cause of emission violations and
adequacy of responsive measures - an outcome Congress intended to prevent with the simple
straightforward enforcement and penalty provisions in the CAA. As a result, the commenters note that

432


-------
enforcement of the CAA could suffer, for civil penalties provide a powerful deterrent to violators as
Congress intended.

Commenters state that the AD also runs counter to two clearly expressed intentions of Congress: (1) the
burden it places on citizens makes it less likely that they will enforce the CAA, see, e.g., Pennsylvania v.
Del. Valley Citizens' Council for Clean Air, 478 U.S. 546, 560 (1986); and (2) several of the factors at
issue in the AD undercut Congress's intent that citizen suit enforcement should avoid re-delving into
"technological or other considerations," NRDC v. Train, 510 F.2d 692, 700 (D.C. Cir. 1974). The
commenters state that both result from the technical burden the EPA imposes on citizens with the AD,
and both render the defense impermissible.

In addition to these problems, commenters state there is simply no need for an AD to penalties to be
written into the regulations and cause the harm that will result. The commenters note that the EPA has
discretion to decide what cases to prosecute, to consider settlements, and to request civil penalties in a
case-by-case manner, as long as it acts consistent with the CAA to protect clean air as its top priority,
see 42 U.S.C. § 7401. The commenters state that promulgating this affirmative defense is equivalent to
giving polluters "get out of jail free" cards for serious emission exceedances and MACT violations. The
commenters note that polluters are likely to claim that any violation of the standard is due to a
malfunction in order to evade the requirements. The commenters state that allowing polluters to evade
financial penalties - which are the real teeth of the standards - through this type of measure is likely to
lead to polluters simply ignoring or factoring potential standard violations into their cost of doing
business, rather than actually trying to prevent malfunctions and violations of the standards as a way to
avoid financial losses from the application of penalties.

Commenters state that assuming arguendo that the EPA had authority to promulgate any type of
affirmative defense to penalties for malfunctions, the EPA should also promulgate the following
provisions:

1.	A specific amount of compensatory damages should apply to each reported malfunction. These funds
should be dedicated to enforcement, inspections, and monitoring in the local community around the
specific facility, to create greater assurance that malfunctions will not happen again.

2.	The EPA should modify the regulations so that the AD cannot be used by a specific facility or
company more than once within a set period of time, such as 10 years. The AD should become
automatically unavailable to a facility that has previously had a malfunction within the last 10 years, to
ensure that this defense does not swallow the value of the standards.

3.	The EPA should promulgate specific public reporting and notification requirements for malfunctions,
or any emission exceedance that occurs of which an operator is aware. Specifically, the EPA should
require that when a facility provides the EPA with a notification of a malfunction or emission standard
exceedance under the regulations, this notice will be made publicly available on the EPA's website
within 14 days. In addition, the EPA should promulgate the requirement that when such notification is
made, the facility must also provide for community notification of the malfunction or emission standard
exceedance within 2 business days, through an appropriate public forum that is designed to reach
residents who live near the facility, including but not limited to a notice on the facility's own website (if
it has one), a written notice to the local municipality and local school district, a press release to the local
newspaper, radio, and TV news station that contains information community members may need to
protect themselves and their families from the additional air pollution.

433


-------
Response to Comment 55: For malfunctions, the EPA is finalizing the proposed affirmative defense
language for exceedances of the numerical emission limits that are caused by malfunctions with minor
revisions as discussed below. As the EPA explained in the preamble to the proposed rule, the EPA
recognizes that even equipment that is properly designed and maintained can fail and that such failure
can cause an exceedance of the relevant emission standard. The EPA is including an affirmative defense
in the final rule as we have in other recent section 112 and section 129 rules so as to balance the tension,
inherent in many types of air regulation, to ensure adequate compliance while simultaneously
recognizing that despite the most diligent of efforts, emission limits may be exceeded under
circumstances beyond the control of the source. The EPA must establish emission standards that "limit
the quantity, rate, or concentration of emissions of air pollutants on a continuous basis." 42 U.S.C. §
7602(k)(defining "emission limitation and emission standard"). See generally Sierra Club v. EPA, 551
F.3d 1019, 1021 (D.C. Cir. 2008) (emissions limitations under CAA section 112 must both continuously
apply and meet section 112's minimum stringency requirements, even during periods of startup,
shutdown and malfunction). Thus, the EPA is required to ensure that section 112 emissions limitations
are continuous. The affirmative defense for malfunction events meets this requirement by ensuring that
even where there is a malfunction, the emission limitation is still enforceable through injunctive relief.
While "continuous" limitations, on the one hand, are required, there is also caselaw indicating that in
some situations it is appropriate for the EPA to account for the practical realities of technology. For
example, in Essex Chemical v. Ruckelshaus, 486 F.2d 427, 433 (D.C. Cir. 1973), the D.C. Circuit
acknowledged that in setting standards under CAA section 111 "variant provisions" such as provisions
allowing for upsets during startup, shutdown and equipment malfunction "appear necessary to preserve
the reasonableness of the standards as a whole and that the record does not support the 'never to be
exceeded' standard currently in force." See also, Portland Cement Association v. Ruckelshaus, 486 F.2d
375 (D.C.Cir. 1973). Though intervening caselaw such as Sierra Club v. EPA and the CAA 1977
amendments calls into question the relevance of these cases today, they support the EPA's view that a
system that incorporates some level of flexibility is reasonable. The affirmative defense simply provides
for a defense to civil penalties for excess emissions that are proven to be beyond the control of the
source. By incorporating an affirmative defense, the EPA has formalized its approach to upset events. In
a Clean Water Act setting, the Ninth Circuit required this type of formalized approach when regulating
"upsets beyond the control of the permit holder." Marathon Oil Co. v. EPA, 564 F.2d 1253, 1272-73 (9th
Cir. 1977). But see, Weyerhaeuser Co. v. Costle, 590 F.2d 1011, 1057-58 (D.C. Cir. 1978) (holding that
an informal approach is adequate). The affirmative defense provisions give the EPA the flexibility to
both ensure that its emission limitations are "continuous" as required by 42 U.S.C. § 7602(k), and
account for unplanned upsets and thus support the reasonableness of the standard as a whole.

Further, the EPA's view is that the affirmative defense is consistent with CAA sections 113(e) and 304.
Section 304 gives district courts jurisdiction "to apply appropriate civil penalties." Section 113(e)(1)
identifies the factors that the Administrator or a court shall take into consideration in determining the
amount of a penalty to be assessed only after it has been determined that a penalty is appropriate. The
affirmative defense regulatory provision is not relevant to the amount of any penalty to be assessed
under section 113(e) because if a court determines that the affirmative defense elements have been
established, then a penalty is not appropriate and penalty assessment pursuant to the section 113(e)(1)
factors does not occur.

In exercising its authority under section 112 to establish emission standards (at a level that meets the
stringency requirements of section 112), the EPA necessarily defines conduct that constitutes a
violation. The EPA's view is that the affirmative defense is part of the emission standard and defines
two categories of violation. If there is a violation of the emission standard and the source demonstrates
that all the elements of the affirmative defense are met, only injunctive relief is available. All other

434


-------
violations of the emission standard are subject to injunctive relief and penalties. The CAA does not
require that all violations be treated equally. Further, a citizen suit claim under section 304 allows
citizens to commence a civil action against any person alleged to be in violation of "an emission
standard or limitation under this chapter." The CAA, however, allows the EPA to establish such
"enforceable emission limitations." Thus, the citizen suit provision clearly contemplates enforcement of
the standards that are defined by the EPA. As a result, where the EPA defines its emissions limitations
and enforcement measures to allow a source the opportunity to prove its entitlement to a lesser degree of
violation (not subject to penalties) in narrow, specified circumstances, as the EPA did here, penalties are
not "appropriate" under section 304.

The EPA's view is that an affirmative defense to civil penalties for exceedances of applicable emission
standards during periods of malfunction appropriately balances competing concerns. On the one hand,
citizen enforcers are concerned about additional complications in their enforcement actions. On the other
hand, industrial sources are concerned about being penalized for violations caused by malfunctions that
could not have prevented and were otherwise appropriately handled (as reflected in the affirmative
defense criteria). The EPA has utilized its Section 301(a)(1) authority to issue regulations necessary to
carry out the Act in a manner that appropriately balances these competing concerns.

The EPA disagrees that the affirmative defense provision will hamper citizen enforcement. First,
injunctive relief is still available and the threat of penalties would not deter violations in cases where all
of the conditions of the affirmative defense have been satisfied because the affirmative defense criteria
ensure that all reasonable steps were taken to prevent a malfunction that causes excess emissions.
Further, litigating whether a source has met the affirmative defense will not burden citizen group any
more or less than would litigating the appropriate penalty amount in the penalty assessment stage of a
citizen suit enforcement action, because the 113(e) penalty assessment criteria and the affirmative
defense criteria are similar and in fact overlap. For example, the requirement that the Administrator or
the court consider "good faith efforts to comply" is bound to generate the type of fact-intensive disputes
that the commenter complains of. In addition, several of the affirmative defense criteria are exactly the
type of criteria the Administrator or Court might consider in determining whether a source made "good
faith efforts to comply." For example, to take advantage of the affirmative defense, the source must
prove by a preponderance of the evidence that, among other things, the excess emissions "were caused
by an unavoidable failure of air pollution control and monitoring equipment, process equipment, or a
process to operate in a normal or usual manner" and "could not have been prevented through careful
planning, proper design or better operation and maintenance practices" and "did not stem from any
activity or event that could have been foreseen and avoided, or planned for."

Thus, the EPA does not expect the affirmative defense provision to significantly alter the burden of
bringing a citizen enforcement action. For those cases that do proceed to trial, even in the absence of this
affirmative defense, sources generally raise equitable arguments to argue for a low penalty and citizens
often rebut such arguments. Therefore, as a practical matter, the EPA does not expect the affirmative
defense provision to materially affect the practice of CAA enforcement.

Additionally, the affirmative defense is reasonable. The EPA's judgment is that the affirmative defense
criteria capture the appropriate considerations in determining whether penalties are appropriate when a
violation occurs as the result of a malfunction. As noted above, the affirmative defense criteria overlap
to some extent with the penalty assessment criteria set forth in section 113(e), but are not identical. For
example, size of business is one of the factors listed in section 113(e), but is not reflected in EPA's
affirmative defense. This reflects the EPA's view that when a violation is caused by a malfunction, the
size of the business is not relevant to whether penalties should be excused. If the violation was

435


-------
unavoidable and could not have been prevented, the EPA's view is that it would be unfair to impose a
penalty no matter the size of the business.

The EPA is not adopting commenters' suggestion with respect to compensatory damages or limits on the
frequency of use of the affirmative defense. It is not clear that EPA has authority to require the
automatic imposition of compensatory damages and even if such authority exists, the EPA does not
think automatic imposition of damages is appropriate. Ensuring that malfunctions do not recur can be
handled through imposition of appropriate injunctive relief. In addition, the EPA's view is that it would
not be appropriate to limit a source's ability to take advantage of the affirmative defense to one time
over a specified period of time such as ten years given that the affirmative defense is only available
when the source could not have prevented the excess emissions. With respect to commenters' suggested
reporting requirements, the reporting requirements in the rules promulgated today already require
malfunction reporting and the affirmative defense provisions require that parties choosing to assert the
affirmative defense meet additional malfunction reporting requirements. Any such reports submitted to
the EPA are publicly available pursuant to CAA section 114.

Further, the EPA disagrees with comments that criticize the affirmative defense criteria as being overly
vague or unduly restrictive and complex. The EPA believes that courts are well equipped and often do
evaluate and apply the type of criteria set forth is the affirmative defense. Many of the conditions were
modeled after the conditions of the affirmative defense in EPA's SIP SSM policy, which several states
have adopted into their SIPs. (See, e.g.. State Implementation Plans: Policy Regarding Excessive
Emissions During Malfunctions, Startup, and Shutdown (Sept. 20, 1999); Policy on Excess Emissions
During Startup, Shutdown, Maintenance, and Malfunctions (Feb. 15, 1983)). We do not have any
indication that parties to enforcement proceedings have had any significant difficulties applying the
terms of these SIP affirmative defenses. In addition, the EPA's view is that use of consistent terms in
establishing affirmative defense regulations and policies across various CAA programs will promote
consistent implementation of those rules and policies. The EPA does not find persuasive commenters'
concerns with potential use of the root cause analysis against the source. The purpose of the root cause
analysis is to determine, correct, and eliminate the primary causes of the malfunction and the excess
emissions resulting from the malfunction event at issue. A sources ability to do so with the benefit of
hindsight after a malfunction has occurred does not necessarily mean that malfunction could have been
predicted or prevented.

The EPA also disagrees with comments that criticize the affirmative defense for shifting the burden of
proof. The affirmative defense does not require a facility to prove its innocence rather than requiring an
enforcement authority to prove a violation of the CAA or change the burden of proof with respect to
establishing a violation. The affirmative defense applies to penalties and thus is only utilized where a
violation has been established. The burden of proof remains with the plaintiff in an enforcement action.
See, e.g.. 40 C.F.R. 22.24. If a violation has been established and a source wishes to assert the
affirmative defense with respect to penalties, the source does bear the burden of establishing that the
elements of the affirmative defense have been met. This burden-shifting is appropriate because the
source is in a better position to determine the facts required to establish the defense. See, e.g., Arizona
Pub. Serv. Co. v. EPA, 562 F.3d 1116, 1120, 1129-30 (10th Cir. 2009) (rejecting industry challenge to
the EPA's use of an affirmative defense to address excess emissions during malfunction events).

With respect to the comment that the affirmative defense should be stated instead in terms that, once a
source has claimed that its excess emissions were related to a malfunction, it will not be considered to be
in violation of the standards unless the enforcement authority demonstrates that the source is not entitled
to claim the malfunction, the EPA does not agree that the affirmative defense should operate as the

436


-------
commenter suggests. The commenter improperly seeks to shift the burden of proof from the source to
the EPA. It is the source, not the EPA, that has the information relevant to assess whether a particular
event qualifies as a malfunction and meets the affirmative defense.

b.	AD for startup/shutdown.

Comment 56: Commenters 17904 and 19120 request AD for excess emissions during startup/shutdown
periods, similar to the AD provided for malfunctions. Commenter 17904 cites the NSPS (approved FIP
for a station) where opacity standards apply at all times except during SSM (40 CFR 60.11), and AD
applies to SSM. Commenter 17904 notes that unlike an exclusion, an AD does not excuse a source from
continuous compliance. Commenter 17904 states that nothing in the Sierra Club decision precludes the
EPA from including an AD for excess emissions during startup/shutdown.

Response to Comment 56:. The EPA is promulgating the affirmative defense for malfunctions only,
not for periods of startup and shutdown. As explained in the preamble, the EPA believes that
malfunction events should be treated differently than periods of startup and shutdown, which are
predictable and routine aspects of a source's operations. In contrast, the EPA has determined that CAA
section 112 does not require that emissions that occur during malfunctions be factored into development
of CAA section 112 standards. Because startup and shutdown periods are part of a source's normal
operations, the same approach to compliance with, and enforcement of, applicable emissions standards
during those periods should apply as otherwise applies during a source's operations. Further, as
explained above, periods of startup and shutdown - but not malfunctions — are taken into account when
establishing section 112 emissions standards. For these reasons, the EPA does not believe it is
appropriate to apply the affirmative defense provision to startup and shutdown periods.

c.	Reporting timeline.

Comment 57: Commenter 17912 states section 63.10001 requires notification as soon as possible but
no later than 2 business days, but the rule text does not allow for circumstances where the facility does
not have knowledge of the malfunction until later. Commenter 179212 states that a source must provide
a preponderance of the evidence that it has met all of the elements set forth in 63.10001 but in many
cases the best a facility can practically do is prepare a best estimate.

Commenter 17772 states that the 2-day statute of limitations on AD is an arbitrarily short deadline and
should be struck in its entirety. Commenter 17772 states that the accused should retain its right to defend
itself against a notice of violation (NOV) and relevant evidence of a malfunction should not be ignored
due to a procedural rule. Commenter 17772 cites an example where emissions are measured by a sorbent
trap and the malfunction may not be found until the trap is removed and analyzed.

Commenter 17772 states that for short-term malfunctions, it may not be known until the end of the 30-
day period that there has been a violation, and a better approach would be to permit the claim to be made
as soon as there is knowledge of the malfunction but no later than 45-days following the event.

Response to Comment 57: The EPA is revising the notification requirement so that it reads " The owner
or operator of the affected source experiencing an exceedance of its emission limit(s) during a
malfunction shall notify the Administrator by telephone or facsimile (FAX) transmission as soon as
possible, but no later than two business days after the initial occurrence of the malfunction or, if it is not
possible to determine within two business days whether the malfunction caused or contributed to an
exceedance, no later than two business days after the owner or operator knew or should have known that

437


-------
the malfunction caused or contributed to an exceedance, but, in no event later than two business days
after the end of the averaging period, if it wishes to avail itself of an affirmative defense to civil
penalties for that malfunction."

d.	Reporting method.

Comment 58: Commenter 17722 states that language in section 63.10001(b) should include "or
delegated authority, as applicable" in addition to "notify the EPA Administrator..." and should replace
"by phone or facsimile..." with "in an appropriate manner such as phone, fax, email, or other electronic
means, as determined by the EPA Administrator or delegated authority."

Commenter 18034 states that electronic reporting, such as complies with CROMERR standards, should
be allowed for the initial notifications, rather than telephone notifications, which should not be allowed,
because telephone notifications are difficult to verify and enforce. Commenter 18034 states that
electronic notification provides quick and durable reporting that may be relied on for investigative and
enforcement purposes.

Commenter 18034 suggests that the EPA allow state rules for AD that are EPA-approved as part of a
SIP, to be used in lieu of the federal procedures, to eliminate duplicative or conflicting requirements for
both state agencies and regulated entities. Commenter 18034 states that TAC includes reporting of
upsets (malfunctions), startups, and shutdowns, that are substantially the same as the EPA's rule.
Commenter 18034 requests that as part of the alternative EPA-approved SIP procedures, consideration
may be given to Texas criteria regarding the percentage of total annual operating hours for emission
events in lieu of frequency.

Response to Comment 58: The definitions in part 63.2 Part 63 defines "Administrator" to mean the
Administrator or authorized representative (e.g. delegated state). The EPA accepts documents in
electronic format, as long as the format is compatible with the requirements of the standards. For the
affirmative defense provisions, the owner or operator of a facility experiencing an exceedance of its
emission limit(s) during a malfunction must notify the Administrator by telephone or facsimile (FAX)
transmission of the exceedance. However, the written reports required to demonstrate that the
affirmative defense provisions have been met and requests for an extension of the deadline for these
reports may be submitted electronically.

Pursuant to EPA regulations at 40 CFR 63.93, states may seek approval of state requirements to
substitute for requirements included in final section 112 standards if the state requirements are
equivalent to the promulgated section 112 standards. States that have SIP approved affirmative defense
provisions may seek to have those programs apply in lieu of the affirmative defense provisions
applicable to malfunction periods in the final rule.

e.	Not require Root Cause Analysis for every malfunction.

Comment 59: Commenter 17923 states that documentation required to assert an AD will impose
administrative burden with no environmental benefit. Commenter 17923 states that a facility should not
be required to conduct a root cause analysis (RCA) for every malfunction for AD. Commenter 17923
states that the ambiguity of the recordkeeping requirements limits confidence in a facility's ability to
demonstrate compliance.

438


-------
Commenter 17851 notes that the rule language assumes that all malfunctions are equally significant and
need an identical degree of investigation. Commenter 17851 notes that a RCA implies a formal process,
and believes a formal RCA should be used only when other reasonable methods fail to show what
caused the malfunction or when the serious nature of an event might make such an analysis necessary.
Commenter 17851 believes a RCA for every malfunction is unnecessary and requires excess efforts with
no environmental gain. Commenter 17851 states that other tools may be more appropriate (e.g., failure
mode and effect, fault tree, etc.) or more powerful tools may be introduced in the future, and the facility
should decide which tool to use. Commenter 17851 suggests the EPA use an alternative term that does
not carry a specific meaning.

Commenter 19040 states that RCA is just one of many types of inductive analyses, and other inductive
techniques should be considered appropriate are the "parts count" approach, FEMA, FMECA, PHA,
FHA, DFM, or RDB. Commenter 19040 also suggests that deductive methods of analysis, such as fault
tree analysis, would be appropriate. Commenter 19040 suggests that the EPA not limit the analysis
technique, the EPA should allow the entity to use the technique that will give the most appropriate
results or conclusions. Commenter 19040 states it is in the interest of the EPA to obtain the most
meaningful results or conclusions on malfunction causes, not to have facilities develop proficiency in
conducting RCA and not identify the malfunction cause.

Response to Comment 59: The EPA believes that a minor administrative burden will result in sources
analyzing their violative emissions to reduce or avoid those emissions in the future, which is an
environmental benefit. A root cause analysis is only required if a source seeks to assert an affirmative
defense. However, such an analysis is beneficial in resolving or preventing violations and excess
emissions whether the source seeks to assert the affirmative defense or not. A root cause analysis is one
example of what constitutes good air pollution control practices to minimize emissions.

A root cause analysis is not required for every malfunction - - only those malfunctions for which the
source chooses to assert an affirmative defense. We agree with the commenter that not every
malfunction is so significant that it would require asserting an affirmative defense. The EPA believes
that sources seeking to minimize emissions will endeavor to find out what went wrong anytime there is a
minor or major malfunction. The facility should decide what level of investigation is needed in each
instance. We agree with the commenter that sources should use appropriate techniques of analysis to
achieve the desired results and conclusions in the event of a malfunction. The EPA joins the commenter
in seeking meaningful results which successfully identify, and address the cause of the malfunction.
However, if the malfunction rises to the level of one that the source seeks to avail themselves of the
affirmative defense, then a root cause analysis is required.

In the context of part 63 section 112, the term "root cause analysis" was used genetically to imply an
analysis of sufficient depth and complexity to indicate whether a malfunction did indeed cause a failure
to meet a standard, provide sufficient information on the nature and causes of a malfunction to
determine whether the source had a malfunction that met the definition of a malfunction, and whether
civil penalties are an appropriate sanction for the violation, if one occurred. The term "root cause
analysis" is not defined in subpart A (the General Provisions) or in the subpart being promulgated,
Subpart UUUUU. The EPA did not intend to prescribe a specific methodology, given that "root cause
analysis" is not a defined term in the applicable subparts of Part 63.

8. SSM limits should be more stringent; emissions are high during SS events.

439


-------
Comment 60: Commenter 17975 states the EPA has not factored SSM emissions into the standards, and
the EPA has not evaluated what monitoring can be done or what can be done to limit SSM emissions.
Based on EGUs in Texas that have recently submitted permit applications for PM during SSM,
Commenter 17975 notes that emission rates for SSM events range from 0.375 to 5.5 lb/MMBtu, which
is 12 to 180 times the 0.03 lb/MMBtu limit set for non-g metals. Commenter 17975 states that facilities
have requested SSM durations of 48 hours at a time and for up to 600 hours per year, and Title V
monitoring reports for 2009 and 2010 for these same facilities show actual duration of SSM events
frequently exceed 100 hr/yr, and more than 200 hr/yr at one facility.

Commenter 17755 states that a majority of PM and opacity excess emissions occur during SSM when
the ESP is not operating.

Commenter 17975states that total PM emissions during SSM events can be 20 times higher than during
normal operations and cited Texas EGUs with PM limits of 216 lb/hr that show 4,788 lb/hr for
startup/shutdown, so that now their annual PM emissions that are currently 946 ton/yr per boiler could
emit up to 1,436.4 ton/yr per boiler if the SSM application is granted. Commenter 17975 highlights
another facility with current emissions limit of 1,033 ton/yr that could emit up to 2,284.4 ton/yr if the
SSM application is granted. Commenter 17975 notes the SSM emission limits requested in the Texas
applications are high and may jeopardize compliance with the EPA's non-Hg metal standard. The
commenter presents an example where they assume SSM periods at 24 hours duration, incorporates
these higher emission levels into the 30-day rolling average, and shows that the emissions range from
0.034 to 0.053 lb/MMBtu, which is far above the standard of 0.03 lb/MMBtu. Commenter 17975 states
that 24 hours of SSM periods would also increase total non-Hg metals to 43 and 47 lb/TBtu for the 30-
day rolling average, which is above the standard of 40 lb/TBtu. The commenter also notes that the
opacity exceedances from SSM events exceed 24 hours, so the emissions would be even higher.

Commenter 17975 states that opacity data, which is a primary indicator of PM emissions, at EGUs in
other states indicate high PM emissions during SSM events. The commenter cites an Oklahoma facility
with 167.1 hr of opacity exceedances per year, and four other facilities with over 40 hours of opacity
exceedances per year due to startup/shutdown. The commenter notes that these estimates are
conservative since they do not include opacity spikes due to maintenance events during normal boiler
operation. Commenter 17975 further notes that these exceedances can be extreme, and cited facilities
with 80 percent opacity for 25 hours.

Commenter 17755 states that their inspectors have documented significant particulate emissions from
COMS data during SSM and offline periods when the boiler may or may not be combusting, with
greater than 400 hours per quarter for some units.

Commenter 17975 states available PM emissions and opacity data suggest that plants would have to
average 10 percent opacity to achieve 0.03 lb/MMBtu PM, however opacity during startup and
shutdown can be much higher, at 60 percent opacity or higher for several hours. Commenter 17975
notes that EPRI data shows PM levels of 0.06 lb/MMBtu with opacity of 15 percent; PM of 0.23
lb/MMBtu with opacity of 25 percent. Commenter 17975 indicates there is not much data relating PM
emissions to extremely high opacity events, but cited data from a Georgia facility that measured 1
lb/MMBtu with opacity at 60 percent, which is 30 times higher than EPA's standard.

Commenter 17975 has reviewed SSM applications in Texas and opacity data from 2009 and 2010 from
the same plants and states that SSM emissions may be even higher than the facilities have estimated.
The commenter indicates that emission calculations assume 30 to 80 percent of fine PM are removed

440


-------
even when the ESP is not operating, because a fraction of fly ash sinks to the bottom of the APCD,
however it is likely that heavier particles would drop out but smaller PM is more likely to be emitted.
The commenter notes that the SSM application for one facility shows maximum emissions estimates
during startup based on heat rate no greater than 693.84 MMBtu/hr, however Title V monitoring reports
for the facility show opacity exceedances at startup of 80 percent or more at much higher heat rates than
those shown as maximums in the application, for example, an opacity exceedance of 93 percent at over
2,500 MMBtu/hr heat input. The commenter states that these much higher heat rates for startup suggest
the emissions can sometimes be much higher than estimated in SSM applications.

Commenter 17975 states that many ESPs are not turned on during startup/shutdown because they
require minimum temperature for safe operation and they cannot function effectively until certain inlet
gas temperature and flow rates are reached. The commenter indicates that ESPs are not turned on while
coal is burned for extended period of time during startup and in the final hours of shutdown.

Commenter 17975 states it is common for ESPs not to be energized until proper operation conditions
occur, and it is clear that permits do not contain limits to minimize startup and shutdown periods of ESP
non-operation. The commenter states PM emissions and opacity are high during these time periods. The
commenter states that high opacity during SSM time periods indicates high PM emissions, and while no
uniform correlation has been developed between opacity and PM emissions, one can reasonably
conclude that periods of high opacity during SSM are periods when PM and non-Hg metal emissions are
high. Commenter 17975 provides examples of opacity and PM data for coal-fired units (see Table X in
EPA-HQ-OAR-2009-0234-17975).

Commenter 17975 states that during startup/shutdown, baghouses can operate at lower temperatures,
may not need to be bypassed at all, and could be bypassed for a much shorter period during startup.

Commenter 17722 states that baghouses do need to be bypassed during startup with fuel oil, as fuel oil
negatively impacts the bags.

Commenter 17957 states the EPA must evaluate maximum control technologies that are most efficient
in reducing SSM emissions and use the evaluation to set appropriate limits. The commenter indicates
that high PM and non-Hg metal emissions are the result of decisions by some EGUs to continue to rely
on ESPs that are not designed to function during startup/shutdown, or because EGUs have chosen not to
explore other alternatives for reducing SSM emissions. Commenter 17975 notes baghouses are more
effective during normal operating conditions, giving units a greater margin to accommodate upsets and
still stay in compliance with 30-day averaging period. Because more than 30 percent of EGUs are
controlled with baghouses, Commenter 17975 states that if MACT standards are based on the most
effective fabric filters as the law requires, SSM emissions would be greatly reduced.

Commenter 17975 states that while the EPA acknowledges that MACT standards must apply at all
times, that does not mean weakening a proposed standard to accommodate SSM, by lengthening the
averaging time for compliance, or treating these episodes as immovable objects, when technologies that
can reduce emission are proven and commercially available.

Commenter 17975 states there are best management practices to reduce emissions during SSM periods,
including: new and existing units should be equipped with baghouse (instead of ESPs) to reduce
emission of PM, including fine PM and thus metal HAP; natural gas should be used as startup fuel,
given that it is available, reduces startup emissions, is not technically challenging, and has modest cost;

441


-------
and the duration of SSM events should be kept to a minimum by defining process conditions that denote
the start and end of the event in enforceable permit conditions.

Commenter 17975 notes that monitoring of non-Hg metals is not required during SSM. The commenter
notes that the monitoring methods identified in the proposal fall far short of what is need to calculated
emissions when boilers are brought down for maintenance and restarted after that work is complete. The
commenter indicates that stack testing is conducted during "normal" operation and testing is not
required to assure compliance during SSM, when emissions are likely to be highest. Commenter 17975
states that absent the evaluation of SSM events and methods to reduce their frequency and severity, as
30-day rolling average designed to accommodate SSM events is an arbitrary standard.

Commenter 17975 notes that deslagging of units as part of maintenance contributes to increased opacity
even though the unit is not operating. The commenter indicates baghouses can remove deslagging PM
far more effectively than ESPs, which would not be energized when the unit is off and when deslagging
occurs.

Commenter 17975 provides examples of drop-out factors used for ESPs to estimate PM emissions
during startup and shutdown, where even though the ESP is non-operational or non-energized, the
collection efficiency is not zero.

Response to Comment 60: For periods of startup and shutdown, the EPA is finalizing work practice
standards instead of numeric emission limits. These work practice standards take into account operation
of APCDs. See the preamble and rule for discussion and requirements. The EPA's rationale for its
approach to malfunctions is discussed in the preamble.

We note that sources that install CEMS or other continuous monitoring devices are required to operate
them at all times. Section 63.10020 clearly states that if you are conducting continuous monitoring,
"You must operate the monitoring system and collect data at all required intervals at all times that the
affected EGU is operating..We believe that it is important to collect data during all process operating
periods including SSM periods, as the rule requires when conducting any continuous monitoring (see
additional responses above relative to the accuracy and utility of such data). The Agency also believes
EGU owners or operators strive to minimize periods of malfunction and should a malfunction period
occur, its duration will be brief, as noted by the commenter. Any impact of potential excess emissions
occurring during a period of malfunction would be offset through use of the rule's 30 boiler operating
day rolling average requirement. To the extent the CEMS records an exceedance during a malfunction,
and the owner or operator believes the measurement was in error, the owner or operator can demonstrate
that the source complied with the standard notwithstanding the CEMS measurement using any available
information.

Commenter's inference that PM emissions during startup may be up to 20 times higher than during is
based on permit information and emissions estimations rather than emissions data. Further, commenter
does not provide HAP data for such periods. We believe that our approach will provide the data
necessary to evaluate these emissions during the 8-year review.

9. Use of multi-metals CEMS and fuel testing for startup fuels.

Comment 61: Commenter 17283 states that use of a multi-metal CEMS allows monitoring of all urban
HAP metals, including Hg and all phases. Commenter 17283 indicates that multi-metal CEMS have
lower initial and on-going costs than the EPA's option of monitoring with two CEMS, and multi-metal

442


-------
CEMS use allows monitoring of emissions directly, so it is not necessary to conduct performance testing
for individual metals.

Commenter 17675 supports the exemption from fuel testing for startup fuels.

Response to Comment 61: For the use of multi-metals CEMS, please see the response to all comments
under Comment Code 5A07b. The exemption for startup fuels is no longer applicable as the proposed
fuel testing requirements are not part of the final rule.

10.	Initial startup.

Comment 62: Commenter 17801 states that neither MACT or NSPS limits should apply during the
initial startup of a facility, should not apply until after the EGU has achieved its Commercial Operation
Date (CCD), or at the earliest, per 40 CFR 60 General Provisions, 60.8 for a performance test
demonstration compliance period that allows up to 180 days after initial commissioning operation.
Commenter 17801 states that the EPA could establish different limits based on initial startup and
commissioning conditions and activities.

Response to Comment 62: For periods of startup and shutdown, the EPA is finalizing work practice
standards instead of numeric emission limits, and compliance with the work practice at initial startup
should not be an issue for sources. Further, commenters have not explained under what authority EPA
would allow a source to not comply with the final rule on the compliance date of the final rule;
therefore, we are not providing the provision suggested by the commenters.

11.	Initial data.

Comment 63: Commenter 17402 states that the EPA cannot establish that the proposed numeric
emission limits represent a reasonable estimate of emissions achieved by the best performers during
startup and shutdown as required by the CAA and the courts in Cement Kiln Recycling Coalition.
Commenter states that, as a result, the EPA must establish work practice standards for these periods.

Comment 64: Commenter 17776 states that the proposed rule would inappropriately require EGU's to
comply with numeric MACT standards during startups and shutdowns even though the agency did not
consider data for startup and shutdown in developing the standards. The proposal is therefore arbitrary
and capricious because the agency relies on inaccurate or unfounded assumptions about such events.
Commenter 17776-11 states that the EPA assumes incorrectly and without adequate basis that startup
and shutdown are predictable and routine, that a 30-day averaging period will accommodate startups and
shutdowns, and that emissions during these periods can be accurately calculated. Commenter 17776-11
states that many outages are unavoidable and unplanned with the effect that the 30-day averaging time is
not adequate given the frequency of outages.

Comment 65: Regarding startups and shutdowns, commenter 17914 cites the following as problems
with the EPA's MACT floor analysis:

•	No startup/shutdown data were considered.

•	Incorrectly characterized solid fuel-fired EGUs as infrequently starting up and shutting down and
using cleaner fuels during startup.

•	Incorrectly characterize startups and shutdowns as predictable and routine.

443


-------
• Limited PM monitor data indicates an order of magnitude higher emissions during startup and
shutdown than during normal operation.

Commenter 17914 recommends that the agency collect a minimum of 30 days of continuous emissions
data, including periods of startup and shutdown, from the top performers and use the data to set the
standard.

Comment 66: Commenter 18034 states that emissions during startup and shutdown were not evaluated
for the proposed emission limits and that the EPA should establish work practices for these periods.
Commenter 18034 states that the boiler MACT rule requires work practices in lieu of numerical limits
for periods of startup and shutdown.

Response to Comments 63-66: The EPA acknowledges that it does not have data upon which to base
numerical emission limits during periods of startup and shutdown. Therefore, the EPA is, in the final
rule, establishing work practice standards for periods of startup and shutdown. In addition, the EPA is
committing to reevaluating this approach during the 8-year review when sufficient CEMS data will be
available from the EGU population.

Comment 67: In commenting that the EPA is not adequately addressing emissions during startup,
shutdown and maintenance, commenter 17975-15 states that opacity exceeded 80 percent during at least
44 hours at Gibson boiler 2 in 2009 after boilers were turned off for maintenance. Commenter 17975-30
provides data showing PM emissions of 0.03 to 0.050 lb/MMBtu at opacities of 10 to 11 percent, which
implies that opacities greater than these correspond to PM emissions greater than the proposed 0.03
lb/MMBtu.

Response to Comment 67: Commenter has not provided data to indicate the impact of these periods of
high opacity on HAP emissions. Further, commenter has not provided, and the EPA does not have, data
on HAP emissions during periods of startup and shutdown. In addition, it is not clear what commenter is
suggesting the EPA do with this information or how we could incorporate it into the MACT standard
setting process. In the final rule, the EPA has specified work practice standards for periods of startup
and shutdown. See the preamble for discussion.

12. Other.

Comment 68: Commenter 17402 opposes the application of the numeric emission limits established for
steady state operations to sources during periods of startup and shutdown. Commenter states that as a
result of the technical infeasibility of measuring emissions and the impracticability of enforcing numeric
emissions limits during those times, the statutory requirements for the EPA's authority to impose a work
practice standard are met. The EPA should, therefore, abandon its approach to enforcing identical
numeric emissions limits during startup and shutdown and, instead, adopt a work practice standard
consistent with its own precedent in the Industrial Boiler MACT rule.

The commenter states that even with the proposed 30 boiler operating day averages, emissions from
these non-representative periods could significantly affect the averages, especially for peaking units or
other units that com on- and off-line frequently. Commenter agrees with the EPA that startup and
shutdown periods are of short duration in relation to the long-term operation of control equipment, but it
is important to note that to maintain the efficiency of control equipment, they must be run in a certain
way during periods of startup and shutdown. The EPA ignores what is well known-emissions control
devices typically perform less than optimally during periods of startup and shutdown. In fact, some air

444


-------
pollution control equipment cannot be operated at all when the boiler is starting up. Commenter provides
examples of how control device operation and efficiency are affected during startup and shutdown and
by the procedures followed to bring pollution control equipment online. In the commenter's experience,
sources controlled using ESP will necessarily have higher Hg emissions during the first 24 hours after
startup especially for plants using ACI to control Hg from subbituminous coal, which cannot be readily
controlled with other technologies. Commenter states that the numeric emissions limitations established
for periods of steady state operations should not be applied to periods of startup and shutdown when
controls are not performing at optimal levels (or are not performing at all until certain temperatures are
reached).

Several commenters (17681, 17714, 17758) also support work practice standards for startup and
shutdown events. Commenters note that work practice standards are consistent with the CAA and has
been done in other MACT rules, such as the industrial boiler MACT rule.

Response to Comment 68: For periods of startup and shutdown, the EPA is finalizing work practice
standards instead of numeric emission limits. See the preamble and rule for discussion and requirements.
The EPA's rationale for its approach to malfunctions is discussed in the preambles to the proposed rule
and this final action.

Comment 69: According to commenter 17402, the EPA argument for not setting emission limits for
malfunctions - that it would be difficult to apply the concept of best performing to a malfunctioning unit
and that it would be impracticable to take malfunctions into account in setting CAA section 112(d)
standards for EGUs - actually argues in favor of the EPA setting a work practice standard as an
emissions standard for malfunction events rather than the numerical emission limits. Commenter
opposes the EPA's proposal to use its discretion to determine an appropriate response in the event of a
malfunction and it opposes the EPA's affirmative defense proposal. Commenter states that under their
current title V operating permit applications, they have established a state-approved plan, which
minimizes malfunction events and requires best practices be followed, that it follows during
malfunctions and breakdowns, which is preferable to the EPA's proposal in which there is a
presumption of non-compliance and is focused on after-the-fact penalty. Furthermore, the EPA's
approach would add yet another burden on the states at a time when states are working with increasingly
limited resources and are already overburdened with regulatory responsibilities. Since it would not be
technically feasible to accurately measure emissions and impracticable to enforce numeric emissions
limits during malfunction and breakdown (for either stack testing or CEM monitoring, which would not
have the ranges required to have accurate data), the statutory requirements for the EPA's authority to
impose a work practice standard are met and the EPA should abandon its approach to enforcing identical
numeric emissions limits during malfunction and breakdown and, instead, adopt a work practice
standard.

Response to Comment 69: The EPA's rationale for its approach to malfunctions is discussed in the
preamble. As explained in those preambles, the EPA has determined that CAA section 112 does not
require that emissions that occur during periods of malfunction be factored into development of CAA
section 112 standards. As the EPA further explained, accounting for malfunctions would be difficult, if
not impossible, given the myriad different types of malfunctions that can occur across all sources in the
category and given the difficulties associated with predicting or accounting for the frequency, degree,
and duration of various malfunctions that might occur. The EPA's rationale for its approach to
malfunctions is not based on the criteria that must be met to justify a work practice standard under CAA
section 112(h). Further, setting work practice standards under section 112 presents the same issues as
setting numerical emission limits given the varied nature of malfunctions. In any event, commenter has

445


-------
not provided support for its assertion that it would not be technically feasible to accurately measure
emissions and impracticable to enforce numeric emissions limits during malfunction and breakdown.
Sources in this category can and do operate multiple measurement systems that measure different
parameters at different points in the generating process and on affected sources and control equipment.
While direct measurement of some factors may or may not take place during certain malfunctions, the
EPA is not persuaded that sources could be left with no means whatsoever to determine whether they
stayed in compliance during a malfunction. Sources may use other available means (including
engineering judgment) or information to demonstrate that the source complied with the standard.

With respect to commenters claim that the affirmative defense will burden the state, many of the
conditions of the affirmative defense were modeled after the conditions of the affirmative defense in
EPA's SIP SSM policy, which several states have adopted into their SIPs. (See, e.g., State
Implementation Plans: Policy Regarding Excessive Emissions During Malfunctions, Startup, and
Shutdown (Sept. 20, 1999); Policy on Excess Emissions During Startup, Shutdown, Maintenance, and
Malfunctions (Feb. 15, 1983)). We do not have any indication that states have had any significant
difficulties applying or implementing the terms of these SIP affirmative defenses.

Comment 70: Commenter 18539 recommends that a startup, shutdown and malfunction plan that is
incorporated into a unit's title V permit is an appropriate work practice standard for startup, shutdown
and malfunction. Commenter 17402 recommends that the EPA adopt a requirement that a unit must
submit an SSM plan for approval and incorporation by reference into its title V operating permit as the
work practice standard for periods of startup, shutdown and malfunction. According to the commenter,
such as approach would ensure that units minimize SSM periods and that appropriate operating practices
are followed during these periods and, thus, would result in minimizing emissions.

If the EPA does not adopt a work practice standard for periods of startup and shutdown, the commenter
requests, in the alternative, that the emission averaging period be increased to a rolling 12-month
average time period as opposed to the proposed 30-day rolling average. In this way, the increased
emissions from periods of SSM would be spread out over a longer averaging period, and the EPA could
potentially show that the limits were achievable even during SSM events.

Commenter 17776 likewise believes that a more stringent approach for startup and shutdown emissions
is not necessary for some types of boilers and encourages the EPA to require compliance with work
practice standards for EGUs as in the Boiler MACT. Failing that, the commenter suggests that the EPA
set special MACT standards for startup and shutdown periods at EGUs based on a reasoned analysis of
data concerning such emissions.

Commenters 17790 and 17851 find the EPA's logic about applying the proposed standards during
startup and shutdown to be flawed because it does not account for the variety of ways in which the
EGUs startup and shutdown and because it is not based on actual emissions during those occurrences.
Commenters point out that PM CEMS are not correlated during periods of startup and shutdown because
the EPA requires full-load operation for CEMs certification testing and the EPA manual test methods
are not designed for transient plant operations. Therefore, Commenters request a separate work practice
standard for use during periods of EGU start-up and shutdown. Commenter 17914 agrees with this
suggestion.

Commenter 18037 recommends that the EPA adopt a work practice standard in lieu of numeric
emissions limitations during periods of startup, shutdown, malfunction and breakdown. The operational
efficiency of control equipment is critical to emissions reduction and these controls must be run in a

446


-------
certain way during periods of startup and shutdown. The EPA's decision ignores that it is well known
that emissions control devices typically perform less than optimally during periods of startup and
shutdown. In fact, some air pollution control equipment cannot be operated at all when the boiler is
starting up.

Response to Comment 70: For periods of startup and shutdown, the EPA is finalizing work practice
standards instead of numeric emission limits. These standards take in to account operation of APCDs.
See the preamble and rule for discussion and requirements. The EPA's rationale for its approach to
malfunctions is discussed in the preambles to the proposed rule and this final action and elsewhere in
this response to comments document. The requirements do not include a startup, shutdown, and
malfunction plan. See Table 3 to Subpart UUUUU of part 63. Commenter's suggestion that its state-
approved plan is prefereable to EPA's approach does not explain how an approach based on such a plan
meets the requirements of section 112.

447


-------
5C07 - Compliance: Other

Commenters: 16849, 16850, 17385, 17402, 17620, 17638, 17648, 17689, 17702, 17714, 17716, 17718,
17719, 17729, 17730, 17736, 17737, 17740, 17752, 17754, 17756, 17758, 17761, 17765, 17767, 17768,
17772, 17775, 17790, 17791, 17795, 17798, 17800, 17805, 17808, 17813, 17818, 17820, 17821, 17840,
17851, 17867, 17868, 17871, 17880, 17881, 17886, 17902, 17909, 17914, 17928, 17930, 18019, 18025,
18034, 18424, 18429, 18477, 18498, 18539, 18541, 18963, 19033, 19114, 19214, 19536, 19537, 19538,
18023

1. Support low emitters alternative compliance.

Comment 1: Commenter 17402 supports establishment of a low emitters alternative compliance, with
modifications. Commenter 17402 states that facilities that satisfy the low emitters standards are
necessarily demonstrating emissions 50 percent to 90 percent below the proposed limits, and these
extremely low emissions should be encouraged with greater compliance flexibility. Commenter 17402
proposes that fuel testing only be required every 6 months. Commenter 17402 also suggests that testing
be based on the reductions capability of the plant demonstrated during the test, not the particular level of
emissions during the test.

Commenter 17754 states that if an affected EGU has been determined to be a LEE (for Hg), it is clear
that such unit's Hg emissions are very low, and as such, these LEE units should not be subject to unduly
burdensome requirements for demonstrating continuous compliance.

Commenter 17176 states the fuel sampling requirements for LEE units are ambiguous, provide no
compliance value, do not require the establishment of a fuel input operating limit, do not address single-
fuel units, changes in fuel type, or units that burn or co-fire multiple fuels. Consistent with the non-LEE
requirements, Commenter 17176 states that LEE units that burn multiple fuel types or blends should
establish a fuel-input operating limit during the initial compliance demonstration, and the EPA should
remove the monthly fuel sampling requirement and allow multiple-fuel LEE units to conduct fuel
sampling only when the fuel type changes. Commenter 17176 states single-fuel LEE units should not
have to comply with any fuel sampling requirements.

Commenter 17754 states the EPA should revise the proposed rule regarding the use of the 90th
percentile upper confidence level for determining the operating limit for mercury (LEEs for Hg).
Commenter 17754 states the rule should be clarified that, while the initial performance test is conducted
over a 2830 day period to demonstrate LEE status, the subsequent performance tests (performed every 5
years) shall consist of three 120-minute runs, unlike the longer duration of the initial performance test.

Commenter 17754 notes the rule should be modified because it is unclear whether a source
owner/operator who demonstrates initial satisfaction with the LEE criteria, but then subsequently fails to
demonstrate continuous compliance with the relevant standards, has the ability to retest the unit to
reestablish its LEE status. Commenter 17754 states a source owner should be afforded the opportunity to
demonstrate that an affected EGU qualifies as a LEE, notwithstanding a prior performance test result
exhibiting emission rates in excess of the threshold. Commenter 17754 indicates the compliance
demonstration methods under the rule provide a highly conservative estimate of Hg emission rates for
purposes of ensuring LEE status, and this conservatism should not prevent such source owner from
demonstrating LEE applicability by more refined analyses.

448


-------
Response to Comment 1: The final preamble describes the final rule provisions for LEE. Because the
proposed fuel analysis provisions are not part of the final rule, the approach to maintaining LEE status
has changed. For mercury, an existing unit may qualify based on an initial Method 30B test, and then
will have to retest annually. If the LEE status is lost based on the results of an annual retest, the rule
requires you to install an Hg CEMS or sorbent trap monitoring system, with quarterly Method 3OB
testing until the monitoring system is certified. You can regain LEE status for that unit if every required
performance test for a 3-year period shows that emissions from the unit did not exceed the LEE limit.
For non-Hg emissions, you can qualify for LEE status if all performance tests conducted over a 3-year
period meet the LEE qualification limit. In that event, you must retest every 36 months to demonstrate
that you still qualify for LEE status. If any subsequent emissions test for that pollutant exhibits
emissions greater than 50 percent of the emissions limit, you must revert to the original emissions
testing frequency until you re-establish a 3-year period of very low emissions no greater than 50 percent
of the standard.

2. Support the EGU NESHAP Rule.

Comment 2: Commenter 17648 states the EGU toxics rule will provide needed regulatory certainty and
will spur investment in new generation controls. Commenter 17648 notes that today we increasingly rely
on aged infrastructure that operates without pollution controls simply because the federal government
has failed to establish legally enforceable emissions standards for toxic pollutants. Commenter 17648
states that the lack of a national standard for toxic emissions continues to be a barrier to investment in
new, cleaner generation capacity as well as the modernization of existing sources. Commenter 17648
states companies are reluctant to build replacement, cleaner generation or to modernize existing plants
when it is not assured that their competitors will be required to comply with modern emission standards,
and it has been found that the installation of pollution controls will raise the marginal costs of
production for those early adopters and place them at a competitive disadvantage relative to those that
do not install pollution controls. Commenter 17648 states the regulatory certainty provided by
the toxics rule is long overdue.

Commenter 17930 supports the EPA's decision that it was not appropriate to set numerical emissions
limits for organic HAP and that a work practice standard would be more appropriate. As stated by the
EPA, the majority of measured organic HAP emissions from EGUs are below the detection levels of the
EPA test methods. They cannot be reliably measured and cannot be subject to emissions limits.

Commenter 18541 states that technologies are available to achieve such reductions, and virtually
eliminate some of these emissions, not only though on-site emissions reductions, but also by switching
to cleaner sources of electricity generation and energy efficiency, and using improved grid system
management within the relevant electricity balancing area.

Commenter 17718 supports the EPA's proposed approach to streamline the continuous compliance
requirements for monitoring, reporting, and recordkeeping. The commenter states that the EPA is correct
in recognizing that the compliance requirements are already applicable to EGUs and eliminating
redundancy wherever possible. The commenter urges the EPA to remain open to additional
accommodations that are identified in the course of implementing the program.

Commenter 19214 states that to demonstrate compliance with both the Boiler NESHAP and the EGU
MACT, the more stringent emission limit should be demonstrated. The commenter states that it is the
responsibility of the source to show compliance with all applicable limits. The commenter supports the
EPA's proposal that compliance with the more stringent emission limit be demonstrated.

449


-------
Response to Comment 2: The EPA acknowledges the support provided in these comments, and
believes the final rule remains consistent with these general areas of support.

3. Performance testing.

Comment 3: Commenter 17808 states the testing requirements are very burdensome and believes the
agency could achieve an equivalent level of compliance assurance with a lower compliance burden with
adjustments.

Comment 4: Commenter 18023 urges the EPA to allow annual filterable PM stack testing as an
alternative compliance option. Commenter 18023 notes that complying with the monthly or bi-monthly
PM or non-Hg metallic HAP alternatives is not practical for the following reasons: (1) both planned and
forced outages will make it difficult to obtain proper unit operating levels, which will stretch the short
term capacity of the testing community nationwide; (2) it is cost prohibitive, as PM testing will cost
approximately $3000 to $5000 per source per month, Hg testing via RM-30B will cost approximately
$10,000 per source per month, and non-Hg metal testing via RM-29 will cost approximately $8,000 to
$10,000 per source per month; (3) analytical results take a minimum of 2 weeks to be analyzed and
reported by laboratories, so a unit could potentially be out of compliance for 2 weeks before analytical
results could be provided; (4) analyzing this data is a difficult scientific proposition - lab technique and
experience are important to avoid biasing the data; and (5) changing compliance and permit limits
monthly based on new test results would place unreasonable operational restrictions on generating units
in an effort to comply with a potentially moving target.

Response to Comments 3 - 4: In the final rule, the optional periodic testing has been reduced to once a
quarter. Sources have the option to use CEMS or PM CPMS in lieu of compliance testing.

Comment 5: Commenter 17775 states EGUs should have flexibility to specify when performance tests
for CEMS and sorbenttrap monitoring systems start. Commenter 17775 notes that
for CEMS or sorbent trap monitoring system, the "performance test" consists of the "first 30 operating
days of data collected with the certified monitoring system." (section 63.10005(a)); section 63.10005(g)
through (j) allows 180 days after the applicable compliance date to "demonstrate initial compliance;"and
"performance tests" also must be conducted under specific operating conditions (section
63.10007(c)). Commenter 17775 objects to the proposed arbitrary designation of the "performance test"
periods. Commenter 17775 states the start of performance tests should not be arbitrarily tied to
completion of monitor certification, but instead, EGUs should be allowed to complete certification tests
on monitoring systems and to use those certified systems to determine whether the shakedown of
emission controls have been successful prior to conducing the "performance test" to establish
compliance with emission limits. Commenter 17775 notes that EGUs also must be able to time the start
of the "performance test" to ensure that it meets the fuel and operating conditions the EPA has specified.
In fact, proposed section 63.10030(d), which requires submission of a "Notification of Intent" to
conduct a "performance test" at least 30 days before it is scheduled to begin, suggests that sources have
the ability to specify a date in advance that may be unconnected to the testing of the monitoring system.

Commenter 17775 states that allowing sources flexibility to specify at what point during the 180-day
period the "performance test" starts not only makes sense, it is in some cases necessary. At a
minimum, Commenter 17775 indicates the EPA needs to allow flexibility for sources to specify the start
of the "performance test" for CEMS that have been previously certified (e.g., SO2 CEMS that were
previously certified under the Acid Rain Program). Commenter 17775 points out that otherwise their
performance test technically could have begun prior to the compliance deadline (or even prior to this

450


-------
rule being promulgated). The commenter states that in addition, for PM CEMS, which do not conduct
anything called "certification testing" (the term "certification" does not appear anywhere in PS 11),
there is no clear point at which to declare that the performance test has begun. Unlike SO2 CEMS,
PM CEMS must be correlated by conducting tests with a reference method and developing a
"correlation curve" that meets PS 11 performance criteria. According to the commenter, once the curve
is developed, the PM CEMS must be programmed so that its output is adjusted consistent with that
curve. The commenter states that none of these actions are consistent with the concept of a system
instantly becoming a "certified" upon completion of a test. The commenter states that although sources
do conduct a 7 day drift test under PS 11, that test is almost always conducted prior to any correlation
testing in order to avoid having to repeat correlation testing if the 7-day test is not passed, and as a
result, the drift test cannot be used to define when the PM CEMS is "certified."

Response to Comment 5: While the EPA does not share the concerns that the commenters have about
relating monitoring system certification with performance testing, final rule has been revised so that 30
day test is not tied to the certification of the CEMS or sorbent trap monitoring system. In addition, as
mentioned elsewhere, the requirements for the mandatory use of PS-11 have been removed from the
final rule.

Comment 6: Commenter 17775 notes that the EPA must recognize that there are limitations on the
conditions under which the EPA can require EGUs to test. To comply with CAA section 112,
Commenter 17775 states the EPA assessed the capabilities of controls under the conditions specified in
the 2010 ICR testing and established compliance testing and compliance assurance requirements
consistent with that assessment. Commenter 17775 indicates the EPA has proposed continuous
monitoring, initial stack testing, or periodic fuel analysis that it presumably believes are consistent with
that assessment; as long as an EGU is complying with one of the options for demonstrating "continuous
compliance," there is no basis to allow the Administrator to specify some other test be conducted under
some other set of conditions.

Commenter 17775 agrees that EGUs should be allowed to use prior tests, however, the EPA should
allow use of any tests conducted under the same conditions, even if those conditions have not remained
unchanged during the entire period since the test (e.g., if there was a period between the prior test and
the current compliance demonstration when a different fuel was combusted).

Commenter 17880 supports the EPA to require affected coal or oil-fired plants to conduct performance
tests that demonstrate compliance with applicable emissions limits.

Commenter 17928 states that the frequency of performance tests required for organics compliance
should be reduced.

Commenter 18025 asks that the EPA give consideration to units already subject to state-level testing
requirements where these requirements provide at least the same assurance as the Utility Toxics Rule.
The commenter notes that their Bridgeport coal unit complies with a Hg emission standard half that
proposed by the EPA for similar units. The commenter states that Connecticut DEP remains confident
that quarterly stack testing provides a sufficient guarantee of compliance. The commenter states that
likewise, the commenter's Hudson and Mercer coal units consistently comply with New Jersey's Hg
requirement through stack testing, and recent test data have shown very low levels of Hg relative to New
Jersey's Hg limit of 3.00 mg/MWh (net). The commenter requests that in similar situations state
requirements be accepted as alternate testing plans for the Utility Toxics Rule.

451


-------
Commenter 17930 states that the EPA has proposed to require an annual performance test, which
includes a "tune-up," but the EPA allows an extended period of up to 18 months "for those EGUs with
unusual planned outage schedules," though there is no standard planned outage schedule across the
industry. The commenter states that many coal and lignite fired units are scheduling 24-month outages;
some have even longer scheduled outages. According to the commenter, in the next few years, it is
expected that the schedule will be extended even more as maintenance practices improve and as
consumer electricity demands, and demands for base load capacity, increase. Therefore, Commenter
requests that the final rule provide the option for performance tests and tune-ups to be conducted on the
existing schedule of each power plant. The commenter states that in the event that the EPA feels there
must be a maximum time limit, it cannot be shorter than 36 months without significantly interfering with
plant operations.

Response to Comment 6: In response to comments, EPA has reduced the duplicative testing of fuels,
HAP surrogates and HAP. Optional periodic testing frequency has also been reduced. The EPA
disagrees with the adoption of various state Hg rules within the final MACT rule. Sources may apply on
a site specific basis for alternative monitoring per 63.8. Neither the proposed rule nor the final rule
required organic HAP compliance testing, so there is no frequency to be changed. The tune-up work
practice and testing has been altered to allow for more flexibility for facilities with less frequent outage
schedules.

Comment 7: Commenter 17775 states that the purpose of section 63.10005(d)(7) "(demonstrate initial
compliance through CPMS)" is unclear. Commenter 17775 is not aware of any option in the rule to
demonstrate compliance using CPMS that measure pollutant concentration. Commenter 17775 states the
EPA should issue a proposal that explains the purpose of this provision so that they can provide
meaningful comment on it.

Response to Comment 7: The commenter is correct that there was no option for initial compliance
option for use of CPMS in the proposed rule and this was an erratum.

4. Frequent testing for liquid oil-fired units.

Comment 8: Commenter 17758 states that frequent performance stack testing (monthly or every other
month) for oil-fired EGUs is impractical, unnecessary, restrictive, and expensive, and notes these units
would have to brought on-line just for the sake of performing the stack tests. Commenter 17758 states
that liquid oil-fired EGUs should perform stack testing no more frequently than annually.

Commenter 17775 states that for section 63.10006(1) and (m) for liquid oil-fired EGUs without HC1
and HF CEMS", the EPA must make it clear that the HC1 and HF testing requirements do not apply
to EGUs using fuel analysis in lieu of performance testing, and that fuel analysis is an alternative to
performance testing.

Commenter 17928 requests that the hours for mandatory unit testing should not be included in the
calculation of oil use. These tests required by the ISO or for compliance with the proposed rule should
be exempt from any "limited use" calculation.

Commenter 17716 states that many liquid oil-fired sources operate infrequently and only during peak
demand periods, and frequent performance testing (monthly or every other month depending on whether
add-on controls are installed) is burden. Commenter 17716 further notes that no correlation was found
between the PM control at oil-fired units and non-Hg metallic HAP emissions, that the emissions

452


-------
of HC1, HF, and non-Hg metals are most closely tied to fuel characteristics, and that changes in fuel
characteristics over time could be tracked to determine if a change in emissions is
likely. Commenter 17716 states the fuel sampling, analysis, and calculation of expected emission rates
are already incorporated in section 63.10021 and should be applied for liquid oil-fired sources.

Response to Comment 8: Under the final rule, liquid oil-fired units have three basic options for
monitoring compliance, with a third alternate a possibility in some situations. First, these units may
conduct quarterly performance tests to demonstrate ongoing compliance. If they choose this option, they
must also conduct site-specific monitoring to ensure compliance between tests (see the final preamble
for further discussion). Second, sources may use CMS for various pollutants. This includes the use of a
PM CPMS to demonstrate compliance with an operating limit established during an initial performance
test that demonstrates compliance with a filterable PM, total HAP metals, or individual HAP metals
emission limits. A source can also elect to use a PM CEMS as a direct compliance method with the
filterable PM standard (see the preamble for further discussion of this option). It also includes the use of
an HC1/HF CEMS for acid gas compliance demonstrations. The third alternative is for fuel moisture
monitoring. This compliance option allows you to monitor fuel moisture (either through direct sampling
of fuel you receive or through fuel supplier certification). Provided that the fuel moisture is no greater
than 1.0 percent, the rule states that you are in compliance with the HC1 and HF emission limits. If
results indicate moisture above 1.0 percent, you must institute one of the other options for monitoring
compliance with the HC1 and HF limits. With respect to the comment concerning the need for HC1/HF
CEMS performance specifications, please see the responses to comments under Comment Code 5A09.

5. Operating limits.

Comment 9: Commenter 18023 suggests BLDS for fabric filters are not necessary, and if BLDS are
required in the final rule they should only be used for purposes of triggering maintenance activities.
Commenter 18023 explains the following for BLDS: (1) this operating limit is purely arbitrary, the EPA
provides no information nor makes any claim that the operating limit quantifiably connected to the HAP
emission limit; (2) the preamble language provides a different requirement where the output of the
BLDS is measured during performance testing and then becomes a BLDS operating limit, this is an
improper use of the BLDS as it attempts to use the system to quantify emission rates; (3) the EPA
guidance document on Fabric Filter Bag Leak Detection Guidance states, "this guidance is not intended
to evaluate changes in the long term performance of the baghouse system, nor does it apply to
applications in which monitoring system attempts to quantify emission rates" (EPA-454/R-98-015
September 1997); (4) the BLDS is more appropriately used to trigger maintenance activity rather than
being used to determine compliance; and (5) bag failures are not acute occurrences and could be
adequately identified in the bi-monthly performance test required by the MACT.

Comment 10: Commenter 18023 suggests setting fixed secondary power input limits for ESPs is
unnecessary, and if the EPA goes forward setting ESP operating limits, the only necessary requirement
should be to ensure that ESP power supplies remain in service. Commenter 18023 explains the
following: (1) ESPs are generally designed to meet a specified performance level with one or
more TR sets out of service, this provides operational margin for malfunction and/or maintenance of
each TR set, a boiler operator would have to perform its compliance test with secondary power
artificially reduced in order to maintain this margin, and this seems to contradict the EPA's desire to
acquire meaningful emission data; (2) process conditions beyond the control of the boiler operator such
as flue gas temperature, fly ash resistivity, and grain loading can affect the power levels of the ESP
without necessarily detrimentally impacting emissions, some margin should be added to the operating
limit to account for this variability {i.e., within 20 percent of the lowest 1-hour average secondary

453


-------
power); (3) because performance does not correlate perfectly with ESP secondary power, a reduction in
power is more appropriately used to trigger maintenance activity (i.e., returning a TR set to operation)
rather than being used to determine compliance; and (4) it is unclear why the proposed operating limits
only apply for EGUs that operate additional wet control systems, the EPA should clarify what
requirements they are proposing for EGUs that operate only an ESP.

Response to Comments 9 -10: The EPA has responded to similar comments under Comment Codes
5A05 and 5A05a. Please see those responses. Under the final rule, there are no operating limits for
control device parameters or any BLDS requirements.

6. Support flexible compliance options.

Comment 11: Commenter 16850 states that electric utilities should be given the flexibility to choose the
most efficient, least-cost compliance options to meet public health and environmental goals.

Commenter 17648 notes the EPA has provided a variety of compliance options, particularly notes that
the EPA provided a flexible array of compliance options for both initial and continuing compliance
demonstrations, and encouraged the installation and use of CEMS but has not mandated CEMS, thus
giving sources reasonable opportunity to design different compliance programs that best align with the
source's short- and long-term plans.

Commenters 17730 and 17820 appreciate that there are several compliance options in the EGU MACT
rule, and states that electric utility industry will need flexibility to achieve compliance with the
requirements.

Comment 12: Commenter 17736 requests that the EPA revise the emissions limitations to reflect the
inherent operational variability of coal-fired EGUs and provide sources with greater flexibility to
demonstrate compliance. According to the commenter, the EPA must give practical consideration as to
how coal-fired EGUs operate. The commenter states that the combustion technologies for coal-based
units drive the selection of emissions controls, such as wet versus dry flue gas desulfurization.

Comment 13: Commenter 17772 states that the proposed rules purportedly leave in place the existing
emission standards for SO2, NOx, and PM as applied under Part 60, subpart Da to existing EGUs. The
commenter states that the compliance provisions as proposed in the HAP regulations, Part 63, to include
all emissions even during periods of SSM makes no adjustments to the currently-effective emissions
levels but makes those levels more difficult to achieve for an existing EGU that is reconstructed or
merely modified, by eliminating the existing SSM exclusions. Commenter recommends that the EPA
reconsider incorporating these SSM exclusions.

Comment 14: Commenter 17791 requests that the EPA recognize the needs of states and regions to
deploy a diverse portfolio of cost-effective supply-side and demand-side resources based on the unique
circumstances of each State and region.

Commenter 18539 states that the EPA takes steps to provide critical flexibility by providing for the use
of surrogates to demonstrate compliance, proposing work practice standards where appropriate and
allowing for emissions averaging. The commenter states that the EPA diminishes the utility of these
flexibility mechanisms-consequently driving up costs and complexity-by placing burdensome and
unnecessary restrictions and requirements on them, without demonstration of substantial environmental
or health benefits and that the EPA's proposed compliance testing and monitoring programs are

454


-------
complicated, confusing and costly, without any demonstration as to why the requirements are necessary
or how they would ensure compliance over the long term even among the existing top 12% MACT pace
setters.

Commenter 19114 asks for greater flexibility so sources can reliably demonstrate compliance, such as
through reexamination of the sources of uncertainty and recalculation of the limits, longer averaging
times, additional options for averaging with other units, as well as development of work practice
standards for known periods when controls do not operate, such as start-ups and shutdowns, or design of
emission rates that can actually be achieved across the whole range of operations a unit would
experience. The commenter states that the EPA should consider the full range of operating conditions
that might be expected over the life of a unit in establishing the final rule. The commenter is concerned
that there is a risk of non-compliance due to unknown and uncontrollable variables, especially for
elements present in trace quantities for which no detailed operational history exists, is significantly
increased. According to the commenter, state agencies have designed permits with limits or work
practice standards that are applicable to specific coal types and/or operating scenarios. The commenter
states that in many cases, permits have been designed that exempt specific operating conditions, such as
startup, shutdown, and malfunction operations, from the emission limits designed for normal operations.
According to the commenter, particularly in the case of EGUs where control equipment is subject to
known operational limits (like safe operating temperatures in the flue gas before electrostatic
precipitators can be energized or ammonia injection for a selective catalytic converter can commence)
the case for the development of work practice standards is strong. The commenter asserts that the EPA's
proposed limits do not provide sufficient flexibility to allow compliance demonstrations to be made
during reasonably foreseeable operating scenarios and must be reevaluated.

Comment 15: Commenter 16849 supports the need for at least a 180-day period to perform all
compliance testing including needed adjustments and repairs to Hg CEMS.

Commenter 17928 states that compliance requirements that are based on calendar months or calendar
quarters, rather than on operating quarters or years, could lead to unnecessary operation solely to
demonstrate compliance, which is undesirable from both an environmental and a financial perspective.

Response to Comments 11 -15: We address comments related to the compliance time and
startup/shutdown/malfunction in the preamble to the final rule and elsewhere in this RTC. With regard
to the flexibility comments, we believe that we have provided the flexibility reasonably allowed under
the statute and court precedent. As noted elsewhere in this document, we have made adjustments to the
monitoring provisions of the final rule that we believe will reduce the burden and complexity while
complying with the statute.

The rule increases the emissions monitoring, reporting, recordkeeping, and testing options available to
EGU owners or operators by adding additional choices, each of which has an averaging time that assures
compliance with emissions limits. The rule no longer contains emissions limits but work practice
standards, including operation of emissions control devices as appropriate, during periods of startup or
shutdown and does not impede development and deployment of diverse energy portfolios. Compliance
options have been simplified, but still assure compliance with emissions limits. While the Agency finds
no impediment concerning averaging periods based on calendar months or EGU operation, the rule
affords liquid oil-fired EGUs whose annual capacity factor is less than 8 percent the ability to meet a
work practice standard, rather than conduct emissions testing, thus preventing the commenter's concern
about unnecessary operation solely to demonstrate compliance.

455


-------
7. Clarifications needed for compliance demonstration.

Comment 16: Commenter 17752 states that the compliance demonstrations require clarification and
revision. Commenter 17752 notes that although the EPA provides a number of compliance
demonstration options, the applicability of many requirements is unclear. Commenters (17752, 17775)
state the EPA must revise the proposal to clarify what requirements apply to each compliance option and
include supporting rationale for each requirement. Commenter 17752 notes the preamble has
inconsistent statements and lacks rational as to when operating limits and fuel input limits apply and
when they do not apply (citing IV. Summary of this proposed NESHAP Section I. What are the testing
requirements? Section J. What are the continuous compliance requirements? Section K. How did we
select the compliance requirements? and V. Rationale for this proposed NESHAP). Commenter 17752
cannot think of any rationale as to why a source with a continuous monitor would also need to comply
with an operating limit, and the commenter believes that the EPA intends for the operating limits and
fuel input limits (including the operating load limit and continuous parameter monitoring systems) to
only apply to EGUs who do not use continuous monitors to demonstrate compliance. Commenter 17752
states that if this is not the case, the EPA needs to include rationale for requiring the operating limits and
provide an opportunity for public comment on the rationale.

Commenter 17775 states these proposed provisions in section 63.10011(b) suggest that some EGUs, i.e.,
those that demonstrate compliance using "performance testing," will need to establish operating limits
and maximum fuel pollutant input levels, and those that do not use "performance testing," will not have
to establish those. However, Commenter 17775 notes that this supposed distinction between EGUs that
demonstrate compliance using "performance testing," and those that do not, does not exist elsewhere in
the rule (or in the Part 63 general provisions); for example, proposed section 63.10000(c)(1) and (2)
require "performance testing" for all EGUs, and proposed section 63.10005(a) and (b) require all
affected EGUs to "demonstrate initial compliance . . . through performance testing ..."

Furthermore, Commenter 17775 notes that Table 5 identifies emissions testing, CEMS, sorbent trap
monitoring, and LEE testing as "performance stack testing." Commenter 17775 states proposed section
63.10005(a) defines "performance testing" to include the first 30-operating days of CEMS data.
Commenter 17775 points out that although proposed section 63.10005(c) allows liquid oil-fired EGUs to
"demonstrate initial compliance ... by conducting fuel analysis," it is not clear whether the EPA intends
that to constitute another form of "performance testing," or an exception to it, and if it is an exception to
it, the other provisions do not reflect that. Accordingly, Commenter 17775 indicates the proposed rule
on its face appears to require all EGUs to establish site-specific operating limits for all controls used to
meet emissions limits under the rule, and maximum fuel pollutant limits for chlorine, Hg, and non-Hg
metals "according to" the cited provisions and paragraphs regardless of the compliance "option" they
choose.

Commenter 17775 states that the EPA must specify that the operating limits (including the operating
load limit) and fuel input limits apply only to EGUs using stack tests to comply, or explain why those
requirements are necessary for other units.

Commenter 17881 states that the EPA must revise the fuel types section in the proposed rule to clarify
what requirements apply to each compliance option. According to the commenter, the EPA must provide
a clear rationale for each proposed requirement.

Commenter 17775 assumes that the purpose of the control device operating limits is to help assure
compliance between performance tests at EGUs that are not otherwise monitoring compliance with the
relevant standard continuously (e.g., at EGUs not using CEMS or sorbent trap monitoring systems), and

456


-------
that the purpose of the fuel input limits are to ensure that EGUs that are not otherwise monitoring
compliance with the relevant standard continuously (e.g., EGUs not using CEMS or sorbent trap
monitoring systems) repeat the relevant performance test if their fuel characteristics change, such that
compliance with the applicable limit at the current level of control is no longer assured. Commenter
17775 can think of no rationale for requiring sources that establish compliance with CEMS or sorbent
trap systems to establish and demonstrate compliance with these other requirements. Commenter 17775
notes that this assumption appears to be supported, somewhat, by the EPA's few preamble statements.
Commenter 17775 states the EPA must revise the rule and Tables significantly in order to make clear
that only those EGUs that demonstrate compliance with a specific HAP or surrogate "through
performance testing other than CEMS or sorbent trap monitoring systems," must comply with these
requirements, or if the EPA does not so revise the rule, the EPA must issue a new proposal and provide a
purpose for what appear to be redundant and unnecessary requirements.

Commenters 17775 and 17790 state that the proposed monitoring and compliance provisions are
difficult to interpret and inadequately explained. According to the commenters, many of the EPA's
proposed provisions simply require compliance "as applicable," but the EPA nowhere clearly states
when the requirements apply. In other cases, the proposed applicability seems clear, but the reason is
not. Commenter 17775 cites an example, that the EPA clearly states in the preamble and in the proposed
rule that EGUs that choose to comply with a surrogate limit must test for the corresponding HAP as
well, and that EGUs that choose to comply with a HAP limit must test for the corresponding surrogate.
The commenter states that the EPA never explains why such testing is relevant, what the EGU is to do
with the results, or how the proposed requirement can be reconciled with other provisions clearly
allowing EGUs a choice between a HAP or a surrogate limit.

Commenter 17871 states that the compliance requirements are duplicative and burdensome and would
not provide any additional protection to public health or the environment.

Commenter 17928 states that the EPA's proposed testing and compliance demonstration requirements
are unnecessarily complex, confusing and burdensome.

Commenter 17795 requests that the EPA provide compliance demonstration flow charts for each of the
categories of affected units. According to the commenter, when regulators conduct required permit
inspections without meaningful flow charts and a clear understanding of multiple paths for compliance,
there will be a tremendous amount of uncertainty for both the regulated community and the regulators.
The commenter states that providing flow charts would make it easier to incorporate this type of
information into existing Title V permits.

Response to Comment 16: The EPA has made changes in the final rule based on these comments to
clarify and simplify the various monitoring and testing requirements. Please see the discussion in the
final preamble. The EPA believes these clarifications eliminate unnecessary duplication and provide
sources with clear options for demonstrating compliance.

Comment 17: Commenter 17820 recommends that the EPA provide clarification that units operating
DSI technology will qualify for the option to use SO2 as a surrogate for HC1. Commenter further states
that the compliance demonstration, recordkeeping and reporting requirements need clarification and
further explanation. The commenter states that the applicability of many requirements, like fuel input
limits and control device operating parameters are unclear, and in other cases, the applicability seems
clear, but the purpose is not or is questionable. According to the commenter, this can be addressed by
providing additional clarity and explanation in the preamble to the rule or more specificity in the

457


-------
regulatory text concerning requirements for performance testing, continuous parameter monitoring
systems, fuel sampling and analysis, control device operating parameters, monitoring and reporting.

Several commenters (17868, 18424, 18963) question the EPA's assumption that a large number of
EGUs will use DSI to control acid gases. The commenter states that while DSI is a lower-cost option to
reduce acid gas emissions, there is nothing in the history of its usage that suggests it is capable of
achieving MACT acid gas emission limits in large EGUs burning medium to high sulfur coal. DSI is not
in widespread use as a basic SO2 control system, and commenter 18963 notes that there have been no
commercially demonstrated applications of DSI for the control of HC1 from coal refuse-fired CFB units.
Commenter 17868 questions the EPA's assumption that the 3-year compliance schedule is achievable
based on the use of DSI systems rather than FGD. Commenter 18424 also questions the EPA's
projection that a large number of EGUs will use DSI to control acid gases, and the use of these controls
will increase the use of high-sulfur coals. According to the commenter, the EPA's own consultant,
Sargent and Lundy, has recommended not employing DSI on units burning coal with greater than 2.0
Ib/MMBtu sulfur content. The commenter states that more than 80 percent of coal mined in Indiana
exceeds 2.0 lb S02/MMBtu, and it seems unlikely that utilities burning Indiana coal will utilize the
lower cost DSI technology and will either install/upgrade scrubbers or retire coal-fired units where
scrubbers are uneconomical. The commenter states that few utilities will install DSI when other
regulatory requirements, such as the SO2 emission reductions under CSAPR, are taken into account.

Response to Comment 17: A unit must use FGD in order to qualify for use of the S02 surrogate, for the
same reasons as stated in the proposed rule. If a source uses DSI and FGD, then that unit would qualify.
The Agency estimates an additional 329 EGUs will choose some form of acid gas control by 2015;
should an owner or operator find DSI unsuitable, he or she could choose from other approaches,
including FGD or FBC with reagent injection. With respect to the remaining general concerns about the
clarity of the monitoring and testing provisions, please see response to Comment 16, directly above.
Comments related to our assumptions with regard to DSI are responded to in the preamble to the final
rule.

Comment 18: Commenter 17821 states that the EPA needs to revise the description and definitions of
the IGCC APCD to account for upstream fuel cleanup and/or pollution prevention measures. The
commenter states that for example, the technology used in IGCC units directly removes contaminants
(such as particulate, Hg, non-Hg metal HAP, sulfur, chloride) directly from the fuel stream of IGCC
units. According to the commenter, in this respect, IGCC is more akin to a natural gas-fired combined
cycle unit, since it burns a syngas, which is cleaner than the coal combusted in a pulverized coal unit.
According to the commenter, the EPA should reflect that IGCCs use upstream gasification/fuel clean-up
(for example, AGR, SRU, PM scrubber) in the same way that coal-fired EGUs are credited for post-
combustion or other air pollution control equipment such as SCR, ESP, and FGD. The commenter states
that it makes no sense for IGCC to have additional testing burdens if reduced testing programs are
allowed for coal-fired units with APCD. According to the commenter, the EPA recognizes that an IGCC
unit is a distinct type of electric generating unit by proposing a separate subcategory for IGCC units, and
the EPA needs to further acknowledge the process differences between IGCC units and PC units by
providing clarification that for purposes of this MACT the affected facility is the combustion turbines
and any emission limitations apply to the heat recovery steam generator HRSG stack. Commenter
recommends that the EPA needs to provide further clarification that all upstream fuel clean-up in the
IGCC process qualifies as control equipment, thereby not putting any additional testing burdens on
IGCC units when reduced testing is allowed for coal-fired units with add-on pollution control
equipment.

458


-------
Commenter 19114 states that for IGCC units, the EPA should clarify the use of heat input and
generation output terminology to account for (1) differences between coal-based (gasifier feedstock -
based) and syngas-based heat input; and (2) differences between syngas-based and natural gas-based
output during co-firing operations.

Response to Comment 18: The final rule does not establish different testing frequencies based on the
presence of add-on controls, so the concerns raised by Commenter 17821 are no longer relevant. As the
final rule contains definitions for coal-fired electric utility steam generating unit, integrated gasification
combined cycle electric utility steam generating unit, and natural gas-fired electric utility steam
generating unit in §63.10042, there is no need for additional clarification. According to the definitions,
an IGCC that co-fires syngas derived from either coal or solid oil fuel with natural gas and get more than
10 percent of the average annual heat input during any of 3 consecutive calendar years or more than 15.0
percent of the annual heat input during any calendar year from syngas, it is an IGCC electric utility
steam generating unit.

The commenters concerns about EPA not accounting for pre-combustions practices that remove HAP
from the syngas are unfounded. Both the input and output based standards applicable to EGUs are
production based limits. The EPA does not determine how a source will meet the standard only that the
HAP emissions (or surrogate emissions) coming out of the stack must not exceed the standard. If a
syngas production process removes sufficient HAP before combustion, the HAP concentration coming
out of the stack should be compliant with the standards, perhaps even without the installation of add-on
controls.

Comment 19: Commenter 17867 states that the EPA should revise and/or clarify some aspects of the
rule.

a.	Adjustments to the provisions concerning testing, initial and continuous compliance with the
standards including:

i.	The frequency of non-Hg metals and HC1 testing should be extended if consecutive testing
shows emissions meet the standard.

ii.	If a source elects to use PM as a surrogate, the emission limit should be established during the
performance test to ensure it correlates with either total or individual non-Hg

metal HAP emissions.

iii.	Filterable PM, as used by the EPA in the final Industrial Boiler MACT, is the appropriate
standard to use as the non-Hg metals surrogate.

iv.	The EPA should adopt work practice standards during periods of startup and shutdown for
sources subject to the rule as used by the EPA in the final Industrial Boiler MACT.

v.	The EPA should not require parametric monitoring for sources electing to show compliance
by utilizing continuous emissions monitoring systems.

b.	The EPA should allow states to request equivalency determinations based on state rules that cover
the same pollutants, but with different control requirements and timing

459


-------
Response to Comment 19: For the issue raised in item (a)(i), please see the discussion of the LEE
provisions in the final preamble. For items (a)(ii) and (iii), the final rule establishes a filterable PM
emission limit as a surrogate to the non-Hg HAP metals standards. This limit applies to all sources as an
option, and is not established on a case-by-case basis. For the issue in item (a)(iv), the final rule requires
the source to meet a work practice limit rather than a numerical emissions limit during startup and
shutdown periods. See preamble for discussion. For the issue in item (a)(v), the final rule does not
require parametric monitoring where a CEMS is used to demonstrate compliance. For item b, these
standards apply as federally enforceable standards. A Part 70 operating permit may provide for certain
streamlining of applicable requirements, consistent with the applicable guidance and requirements that
govern the Part 70 program.

Comment 20: Commenter 17881 states that the requirements of section 63.10031 should not apply to
start-up/shutdown and flame stabilization fuels.

Comment 21: Commenter 17928 requests the EPA to provide clarification on the compliance
requirements for units that may change from being "natural gas-fired" to "oil-fired". According to the
commenter, the proposed rule is unclear with regard to how much time the EPA would allow a newly-
designated oil unit to schedule and conduct initial performance tests to demonstrate compliance with the
applicable standards.

Response to Comments 20-21: While the rule no longer requires compliance with emissions limits
during periods of startup or shutdown, the rule maintains reporting requirements associated with the
work practice requirements during those periods.

8. Cannot meet compliance deadline.

Comment 22: Commenter 18023 indicates that the requirement in section 63.10005(g) to demonstrate
initial compliance for existing sources no later than 180 days after the compliance date is problematic
for sources that may be in an outage or temporarily not operating on the compliance date. Commenter
18023 states the EPA should clarify that compliance demonstrations must be complete within 180 days
after the compliance date or, if the unit is not operating on the compliance date, then 180 days after the
unit begins operation. Commenter 18023 further states that given the concerns that the proposed rule
provides inadequate time to install controls, it is likely a number of utility units will be shut down on the
compliance date.

Commenter 17714 states that the 3-year compliance deadline could be problematic because utilities
must also consider the potential impact of the GHG NSR permitting requirements that could be triggered
for large emission control projects, especially wet flue gas desulfurization projects. The commenter
states that the "Tailoring Rule" provisions can be triggered by some projects because of the required
timing of emission control projects necessary to meet the emission limits of the proposed rule, thus
initiating the GHG BACT analyses requirements during the permitting process. The commenter states
that GHG B ACT is a largely unchartered area for both the regulated community and the state regulatory
agencies and will likely create additional permitting delays. According to the commenter, these delays
will be exacerbated by challenges to the permits by those seeking to minimize GHG emissions.
Commenter recommends the EPA include an exclusion from the requirements to obtain construction
permits, including greenhouse gases under the Tailoring Rule, for emissions controls needed for an
existing unit to meet the emission limits of the Utility HAP MACT Rule.

460


-------
Commenter 17736 states that a 3-year compliance requirement is not feasible. Commenter disagrees that
the data proposed in the regulation is complete and it relied on faulty assumptions and unproven
technologies. According to the commenter, compliance and implementation requirements under the
proposed Utility MACT Rule are unreasonable and overly burdensome for the regulated community.

Response to Comment 22: The rule maintains the requirement for existing EGUs to demonstrate initial
compliance within 180 days after the compliance date of the rule. Source owners or operators have the
ability to schedule equipment installation, if needed, as well as EGU operation so that the requisite
emissions demonstration can be completed on time. Should an owner or operator find that despite his or
her best effort to meet the compliance date additional time is required to install controls, he or she can
request up to a 1-year extension from the Administrator.

Some commenters thought that EPA permitting could cause delays in implementing this rule. The EPA
recognizes that, following the vacatur of the new source review (NSR) pollution control project
exemption in New York v. EPA, 413 F.3d 3, 40 41 (D.C. Cir. 2005), pollution control projects,
including pollution control projects constructed to comply with this rule, have the potential to trigger
NSR permitting. Based on an analysis done in 2005 that looked at SCR and FGD for CAIR compliance,
but that remains current and relevant for all pollutants except for GHG, EPA believes that NSR
requirements would not significantly impact the construction of pollution controls that are installed to
comply with this rule. In addition, it is very unlikely that pollution control projects would cause GHG
increases that would exceed the 75,000 tons per year threshold either as a result of either chemically
manufacturing GHGs or as a result of parasitic load. The EPA concludes therefore that there will be no
significant impacts on timing from NSR for any pollution control projects resulting from this rule.
Should NSR be triggered it would at most be for just a few of the projected control installations. In the
limited circumstances where pollution control installations under the Mercury and Air Toxics Standards
may trigger NSR, we also note that an expedited permitting process can occur with sufficient time to
obtain permits and achieve emission reductions. For this reason, we strongly encourage permitting
authorities to expedite permitting for any such projects, which are likely to be very limited in number.

Some companies may construct replacement generation as a compliance strategy. State pre-construction
permitting requirements depend upon each individual state. Some states do not require pre-construction
permits while some others require public utility commission (PUC) approval. For states obtaining PUC
pre-approval for cost recovery, authorization typically averages seven months and is obtained usually
within one year.19 Furthermore, while PUC approval is necessary to recover investment costs through
rate payers, it is not a prerequisite for obtaining credit or performing conceptual studies.

Comment 23: Commenters 17689 and 17790 state that the DSI technology can achieve the levels of
reduction necessary on EGUs using high chlorine eastern bituminous coals to meet the proposed MACT
HC1 limits. According to the commenters, the alternative control option of FGD cannot be timely
installed to meet the proposed compliance deadline as the EPA admits.

Commenters 17689 and 17886 state that the EPA's determination that over 56 GW of needed DSI
technology can be installed in time to meet the compliance deadline raised issues related to whether the
installation of dry scrubbers could be accomplished in time and whether the additional demands for the
dry sorbent would be available in time.

19 "Public Utility Commission Report" March 31, 2011 by M.J. Bradley & Assoc LLC; web site:
http://www.epa.gov/ttn/atw/utilitv/puc study march2011.pdf

461


-------
Commenter 17790 disagrees with the EPA's assumption that DSI with fabric filters will provide
compliance-level reductions to meet the very stringent acid gas limits at all units. Without data that
demonstrates otherwise, Commenter 17790 expects compliance with this proposed rule will require
FGD on over 60 percent of coal-fired EGUs.

Commenter 17765 states that the DSI technology has not been widely used or tested to date and there is
little or no satisfactory evidence which demonstrates that an actual unit can comply with all of the
proposed NESHAP using DSI without a scrubber.

Commenters 17765 and 17820 believe that without further testing to confirm that DSI technology will
work without a scrubber, it is highly unlikely any utility's compliance strategy will rely only
on DSI technology. The lack of experience with the DSI technology also highlights the problem with
setting emissions standards pollutant-by-pollutant, as there is also insufficient data to confirm whether a
unit using DSI with or without a scrubber can meet all three standards on a continuous basis without
creating antagonistic impacts to the overall effectiveness of other control technologies.

Commenter 17820 states that to satisfy the HC1 emission limit of 0.002 lb/MMBtu as proposed in the
rule, DSI may be a viable option at a reasonable cost for coal with chlorine < 300 ppm. The commenter
states that for coal with chlorine between 300 to 1000 ppm, DSI could still be used but variable
operating costs will increase substantially, while for coal with chlorine greater than 1500 ppm, removal
requirements will be difficult and variable operating costs could approach $8-$10/MWh or higher.
According to the commenter, some companies that burn certain eastern bituminous coals may not be
able to achieve compliance with the acid gas standards using DSI, because the higher chlorine content
found in these coals necessitates a more aggressive control technology to remove higher levels of HC1.
According to the commenter, to comply, these companies may have to install wet FGD, which presents
major challenges to the 3-year compliance deadline that the EPA optimistically asserts companies will
be able to meet.

Commenter 17820 states that the EPA assumes that an adequate supply of dry sorbents is readily
available in the RIA, yet sorbent production would need to increase by 10 to 20 times in order to meet
the EPA's projected DSI demand. The commenter states that it is uncertain whether suppliers will be
willing to increase production without concrete assurances of future demand through mechanisms like
take-or-pay contracts; uncertainties about the future power market and potential problems from DSI use
will make companies' decisions about employing DSI complex and lengthy, and some may be reluctant
to take on large take-or-pay obligations. The commenter states that even assuming suppliers are willing
to commit hundreds of millions for plant expansions that may be needed to increase supply, it will still
take more than 18 months to ramp up dry sorbent production. The commenter states that there are also
substantial questions about the Trona supply chain. According to the commenter, the sole regional
supply of Trona from the Green River, Wyoming area takes two to four weeks to deliver, Trona is
shipped by rail in sealed pressure discharge ("PD") railcars that typically hold a little less than 100 tons
of product, and Trona properties and feed issues limit the size of a plant's storage silo to 200 to 300 tons.
The commenter asserts that given the space constraints at many facilities, a large quantity of Trona will
need to be stored in rail yards on the PD railcars, and it is unclear whether there are enough PD railcars
to accommodate such an expanded use of DSI. The commenter states that if rail service is unavailable to
a given power plant, then trucking the material to the site may cause additional logistic problems
because of the large number of truck trips needed at substantially increased cost. The commenter also
states that material suppliers recommend that Trona not be stored for more than one month because
longer storage times may diminish the material's effectiveness and negatively affect the product's flow
ability. According to the commenter, this storage restriction will have repercussions throughout the

462


-------
supply chain. The commenter states that the RIA is overly optimistic about the use of DSI and, in turn,
understates the cost of complying with the proposed MACT limits (because more units will need to
install either a more expensive wet or dry scrubber). According to the commenter, consequently, the
time estimated to comply with the proposed rule is also understated.

Commenter 17821 states that a number of technical issues must be adequately answered before utilities
can proceed with widespread adoption of DSI technology. According to the commenter, the use of DSI
has substantial crippling impacts on other pollution control systems currently in use at utilities.

a.	According to the commenter, increased mass loading combined with increased ash resistivity can
increase PM emissions. The commenter states that calcium-based sorbents have higher inherent
resistivity, making it very difficult to collect in an ESP and resulting in deteriorated performance. The
commenter also states that sodium-based sorbents shave acceptable ash resistivity for applications

in ESPs, but under certain conditions sodium bisulfate is formed. According to the commenter, sodium
bisulfate has a sticky phase at temperatures above 330 °F-350 °F, and this sticky phase has caused
significant operational problems in a number of units, causing plug gage of systems and components in
the gas stream. According to the commenter, under certain conditions, sodium-based sorbents can serve
as a catalyst to convert NO to NO2. This can cause an orange brown color in the stack plume

b.	The commenter states that regarding fabric filters and DSI, there is not a sufficient number of
medium-to-high sulfur coal burning units that are equipped with fabric filters to determine whether they
can operate reliably without experiencing degraded bag life from acid attack or H2SO4 dew point
corrosion, plug gage and/or blinding. DSI for fabric filter protection is not an industry standard.
According to the commenter, there are operational and reliability risks in installing fabric filters on
large EGUs burning medium to high sulfur coals. The commenter states that the negative effect

of SO3 from high sulfur coals on ACI for Hg control is well documented in DOE studies. According to
the commenter, installing a fabric filter on a large EGU burning medium to high sulfur coals is not a
simple "off the shelf' solution for Hg control;a fabric filter with DSI may hinder a unit's ability to meet
the proposed MACT limits for Hg and PM. The commenter states that in one test where both DSI and
ACI were injected upstream of a polishing fabric filter, the addition of DSI caused the unit to need three
times the normal amount of ACI to achieve the same level of Hg control. The commenter also states that
in addition, for a large majority of DSI cases, retrofitting a fabric filter would be required, an installation
that will take at least 30-35 months in general to complete; this is after the facility has the necessary
approvals such as an air permit, specifications completed, and a contractor secured before it can actually
commence construction. According to the commenter, these steps could easily add several additional
months; total project length including these other factors could easily be 42 months. The commenter
states that in its proposed rule, the EPA has underestimated or not considered these additional burdens of
installing fabric filters, activated carbon, and sorbent injection.

c.	According to the commenter, companies may need to install other technologies such as wet FGD,
which has an expected implementation time of 52 months after necessary permits and other approvals
are secured. The commenter states that this point is critical given that the EPA finalized CSAPR in July,
2011, with a compliance date of January 1, 2012, a quick turnaround that will force some companies to
commit to FGD installation to meet S02 requirements. According to the commenter, even if a company
were to decide on August 1, 2011 to install an FGD, which is four months before the Utility MACT is
scheduled to be finalized, there is still not enough time to permit and install an FGD three years after a
final MACT rule.

463


-------
d. Commenters 17821 and 17840 state that with injection rates of Trona at approximately 600 lb/hr,
engineering studies have shown HC1 removals at less than 20% with virtually no HF removal across a
fabric filter. According to the commenters, the EPA needs to qualify the assumptions on how
much DSI is required for acid gas removal to meet the emission limits required in this rule. The
commenters state that there are not enough engineering data that both demonstrate compliance level
removal rates and document accompanying balance of plant effects; for example, larger alkali injection
rates can cause pH upsets in downstream systems and environmental controls. According to the
commenters, the injection of Trona in an EGU generates N02 which degrades activated carbon.

Commenter 17881 states that additional time is needed to thoroughly evaluate the feasibility of DSI, as
such, considerable additional investigation on the widespread application of this technology is
warranted. According to the commenter, the use of DSI will likely require a fabric filter to
avoid NSR and PSD permits. The commenter states that while DSI may be installed in less than three
years, engineering, permitting and constructing a fabric filter will, in fact, take longer, and that this
concept is further complicated by any need to replace existing ash handling systems in order to
accommodate the higher volume of wastes (i.e., fly ash and spent/unspent reagent) associated with DSI.

Several commenters (17756, 17758, 17790) are concerned that the EPA overestimated the number of
DSI devices that will be used. Commenters 17758 and 17790 note that units burning eastern bituminous
coals may not meet the acid gas standard using DSI; therefore they may use FGD instead.

Commenter 18037 states that the presumption that sorbent injection or dry scrubbing will be installed
over wet scrubbing systems implies that the EPA is looking solely at this proposed rule and not the suite
of rules the electric generating industry will be facing. According to the commenter, when considering
all the rules, wet scrubbers may be the control of choice over dry systems and the installation time for
wet scrubbers is significantly longer.

Response to Comment 23: As mentioned in the response to comment 17, the agency finds that a
number of additional EGUs will choose some form of acid gas control by 2015; should an owner or
operator find a particular approach such as DSI unsuitable, he or she could choose from other
approaches, including flue gas desulfurization or fluidized bed combustion with reagent injection.

Source owners or operators have the ability to schedule equipment installation, if needed, as well as
EGU operation so that the requisite emissions demonstration can be completed on time. Should an
owner or operator find that despite his or her best effort to meet the compliance date additional time is
necessary for the installation of controls, he or she can request up to a 1-year extension from the
Administrator.

9. Request to modify compliance requirements.

Comment 24: Commenter 17800 requests the EPA to exempt EGUs from the annual tuning
requirement in section 63.1002l(a)(16)(iii) and (iv) if such units use a continuous tuning algorithm to
optimize the air-to-fuel ratio, and minimize NOx and CO production. The commenter states that in
section 63.1002l(a)(16)(iii) and (iv) the EPA is requiring the annual inspection of systems controlling
the air-to-fuel ratio and optimizations of CO and NOx consistent with manufacturer's
specifications. According to the commenter, while the EPA references air-to-fuel ratio, typically boiler
operators use excess O2 to determine proper combustion; the general indicator of incomplete combustion
is high CO levels or unburned carbon in the fly ash, and operators use O2 set points to insure combustion
has been optimized. Currently Commenter uses a neural network computer system to optimize the boiler
combustion and minimize NOx and CO production; this system continually tunes the boiler combustion

464


-------
process based on boiler operating parameters. According to the commenter, an annual optimization is
unnecessary, as this is being done continuously.

Response to Comment 24: The EPA has decided not to include alternate work practice standards, such
as a CO requirement, but has adjusted the language in the final rule to recognize the value of automated
boiler optimization tools such as neural-net systems. The EPA has reviewed the comments on the
proposed frequency of tune-ups, and made adjustments in the final rule. See further detail in the
response below on the timing of tune-ups required under the final rule.

Comment 25: Commenters 17800 and 17881 state that in section 63.1002l(a)(16)(ii) the EPA is
requiring flame pattern inspections and that to make this happen, the EGUs need to install observation
ports. Commenters request the EPA to exempt them from this requirement as inspecting the flame would
not provide useful information relative to optimizing CO and would be extremely expensive, as tubing
in the boiler would have to be reconfigured to accommodate the port. According to the commenters, in
some wall-fired coal boilers, there are observation ports which can be used to determine if flames are
impinging on the furnace walls. The commenters state that while a qualitative evaluation can be made
regarding the general appearance of the flames (bright, dark, etc.), observation of the flames is rarely, if
ever, used to access the impact on NOx or CO; for instance, flame observation on cyclone and coal-fired
tangential boilers would not generally be useful. According to the commenters, the cyclone itself is the
burner and the flame is opaque;, in general, the furnace of a tangential boiler is essentially the burner as
well, and in the case of a coal-fired tangential boiler, the furnace is filled with a spiraling flame that
covers most of the furnace. The commenters state that the EPA has apparently recognized this by
requiring that the flame pattern must be inspected "as applicable " Nevertheless, Commenters request
exemption for those boilers that do not currently have observation ports or it can be shown that
observation of the flames in these boilers provides no useful information relative to minimizing CO.

Response to Comment 25: The EPA has modified the rule to state that if specific aspects of the
inspection process are not applicable to a given boiler type, then those elements of the basic procedure
would be adjusted according to best combustion engineering practice for that burner type.

Comment 26: Commenter 17818 states that for compliance, it appears that the alternate limit in this
case (of alternate Hg limits) would require both a simultaneous significant emissions reduction to the
levels of the primary limits and a significant reduction in unit heat rate [when an Hg emission rate limit
of 1.0 lb/TBtu or 0.008 lb/GWh and the apparent correction factor (unit heat rate) of 8000 BTU/KWh is
applied]. According to the commenter, this scenario seems unlikely for most owners and operators.

Response to Comment 26: Conversion errors made in the proposed limits were brought to our attention
and corrected. We believe that the final limits do not contain the issues noted by commenter.

Comment 27: Commenter 17821 states that existing IGCC units should be able to use SO2 as a
surrogate for acid gases (e.g., HC1) as an alternative to measuring HC1 since SO2 emissions are
controlled upstream via acid gas scrubbing to reduce sulfur. Commenter collected SO2 data during the
ICR test at Wabash River IGCC and provided that data to the EPA as requested. Commenter has
submitted to the EPA well over a decade of SO2 data under the Acid Rain Program. According to the
commenter, at a minimum, the EPA could set an SO2 surrogate limit to be the same value as other coal-
fired units, or the EPA could use data from the two existing IGCC sites. The commenter states that the
EPA should not limit having SO2 as a surrogate just to units with a FGD system when other proven and
effective SO2 emissions reduction technology exists and states that as an example, General Electric's
gasification technology, currently being installed at the Edwards port IGCC, uses water scrubbing of

465


-------
syngas at high temperatures which removes water soluble acid gas compounds such as HC1, HCN, HF,
and Cl2. The commenter states that the emission controls for the Wabash River and Polk Station IGCC
units have their own variations, which are distinctively different from conventional coal-fired units.
Commenter proposes that new and existing IGCC units should have the opportunity to use S02 as a
surrogate measurement of acid gases.

Response to Comment 27: The EPA has acknowledged that IGCC EGUs qualify for the alternate SO2
compliance alternative in the final rule and has based such limits on the two operating IGCCs.

Comment 28: Commenter 17881 states that to measure the mass flow of air and fuel to maintain a
desired 'ratio' does not work. The commenter states that facilities will periodically calibrate flow
transmitters on the air measurement system and coal feeders on some plants, and boiler firing controls
are based on maintaining boiler drum pressure and trim air in order to maintain a desired excess 02
leaving the boiler; enough coal is put in to combust and maintain pressure, and enough air is put in until
a desired excess oxygen is achieved leaving the boiler. The commenter states that coal properties vary
greatly (heating content and moisture), so coal feed rates at a desired load can vary greatly, and
consequently, the mass of air entering the boiler varies greatly.

Response to Comment 28: The EPA recognizes the inherent difficulties of combustion optimization
and has modified the rule language to allow more flexibility in conducting tune-ups and maintaining
combustion controls, including incentivizing the use of neural net combustion optimization systems.

Comment 29: Commenter 17902 states that each power plant is anticipated to require at least one
additional full-time person to perform necessary MRR compliance demonstration tasks that are required
on a daily, weekly, monthly, quarterly and semi-annual basis. According to the commenter, this does not
include the external resources and costs associated with stack testing or fuel analyses. The commenter
states that these MRR requirements are duplicative and excessive and would provide no further
assurance of compliance with the emission limits in the Utility MACT Standard.

Response to Comment 29: The EPA has decreased the frequency of required testing and work practices
to levels that are expected to significantly reduce the issues raised by the commenter.

Comment 30: Commenter 17914 states that while many of the proposed provisions of the rule are
technically achievable, there are some limits which are not sustainable in day-in/day-out operation at
EGUs which face a complex mix of fuel variability, combustion management, turbine integration and
Air Quality Control Systems(AQCS) performance optimization challenges and constraints. Commenter
requests that the EPA reconsider several aspects of the rule, which as proposed would severely hinder
reliable, long-term operation of these key assets in our nation's energy infrastructure and seriously
jeopardize the addition of new, more efficient fossil fuel EGUs.

Response to Comment 30: The EPA believes that variability has adequately been addressed in setting
the MACT limits in the final rule as explained in response to other comments in the final rule record.

Comment 31: Commenter 17930 states that the EPA has provided no evidence that the amounts of ACI
reductions that have been achieved are not the maximum capabilities that can be achieved at those units.
According to the commenter, the ACI technology cannot deliver results that even approach the degree of
control or consistency that the EPA claims. Using the same ACI control technology to the fullest extent,
and operated in the same manner, over multiple units, Commenter has experienced mercury emissions
reductions ranging from 30 percent to 80 percent - far below the EPA's predicted reductions of over 90

466


-------
percent and nowhere close to the consistency that would justify setting a limit such as that proposed by
the EPA.

Commenter 18498 disagrees with the EPA proposal not to use technologies other than ACI as the basis
for a beyond-the-floor analysis related to Hg emissions. The commenter states that Mercury Oxidation
System Technology and addition of calcium bromide during the combustion process are control options
that are being examined by Commenter and others. According to the commenter, given the stringency of
the proposed standards and emerging technologies, the EPA should not limit the proposal to ACI and
DSI. Commenter recommends that the EPA consider additional options that would allow for compliance
while protecting grid reliability and reducing retrofit costs passed to consumers; for example, a viable
option would allow a facility to operate at a reduced capacity factor rather than being required to retire
or achieve the standards in the proposed rule. The commenter states that allowing a facility to adopt a
capacity factor of 10 percent or less would achieve the desired result of reducing emissions but would
not place the EPA in the position of dictating energy generation profiles and that such an option would
help ensure reserve capacity for the grid and at the same time reduce emissions. According to the
commenter, the EPA has set a standard that will be difficult for sources to comply with using technology
the EPA has recommended in the proposed rule. For example, states the commenter, using DSI
technology to meet the acid gas HAP emission limits actually makes it more difficult to comply with the
PM emission limits because the dry sorbent injected into the flue gas stream reacts with SO2, creating
sodium sulfate, a particulate that must be captured by the PM control device in addition to the other
particulates in the flue gas stream. Commenter suggests that the EPA revise its proposal and set a
new MACT floor based on the best performing 12 percent of units overall, rather than the best
performing 12 percent of units for each pollutant. According to the commenter, using a methodology
that considers emissions limitations for all regulated pollutants actually achieved in practice by the best
performing 12 percent of sources will result in a MACT standard that complies with section
112(d)(3)(A), and abandoning the pollutant-by-pollutant approach will take into account the interactions
between pollution control devices. The commenter states that although DSI has produced some short
term promising results, there are no long term units operational for prediction of potential unintended
environmental concerns, but it is known that sodium bicarbonate from the DSI process is a base that will
be disposed with coal ash, in many instances in ponds. The commenter states that where a base is added
to the pond, the water will necessarily have to be treated with an acid to decrease the pH in the pond; at
this time, there is insufficient information to know either the amount of treatment that will have to occur
or the ramifications to existing ponds, and thus, at this time there is insufficient information to assess
whether DSI will be an appropriate long term solution.

Response to Comment 31: The EPA believes that the results from ICR testing for units in the low Btu,
virgin coal subcategory that were also using ACI, in combination with the publically available
information from the DOE/NETL mercury control demonstration program, supports that consistent
mercury removal levels > 90% are achievable when the correct sorbent is properly used (i.e., injected
corrected and at the correct rate). The EPA understands and acknowledges that control technologies
other than ACI are also available that can achieve deep reductions in mercury control. This rule does not
mandate the use of any particular control technology (such as ACI). The comments on the pollutant-by-
pollutant approach have been addressed elsewhere in the response to comments document.

Comment 32: Commenter 17702 states that the EPA's proposed compliance requirements are overly
burdensome and should be modified. According to the commenter, some of the compliance
requirements may result in periods of noncompliance by EGUs that may be capable of complying with
the emission limits under normal operations.

467


-------
Response to Comment 32: The final rule makes a number of changes to streamline the compliance
requirements. Please see the final preamble for further discussion.

10.	Need clarification on output-based limitations.

Comment 33: Commenter 17385 states that Tables 1 and 2 of the NESHAP list output-based limitations
in units of mass of pollutant per electrical output (lb per MWh, lb per GWh). The commenter states that
there is no legend to clarify net or gross bases or if only electrical output is included but that in the
Federal Register preamble discussion of the NESHAP limitations, Table 10 (76 FR 25027) does include
a legend that clarifies units and their bases.

Response to Comment 33: The rule requires electrical output based on gross generation; all Tables
have been updated to specify gross generation.

11.	Improve sustainable efficiency.

Comment 34: Commenter 17620 states that the EPA should develop a record in the upcoming EGU
GHG regulations that would enable accurate measurement and determination of sustainable efficiency
improvements. According to the commenter, the record in this rulemaking is not sufficient to establish
such procedures.

Response to Comment 34: Any GHG related comments are outside the scope of this rulemaking.

12.	Support work practice standards.

Comment 35: Commenter 17790 supports the use of work practices standards included in the
proposed EGU MACT to ensure compliance with the proposed organic HAP. Commenter also agrees
that emissions from coal-fired boilers will likely be less than detection limits for most organic HAP, and
further comments that this testing can be expensive and because of the low levels, results can be
unreliable. According to the commenter, proper combustion will ensure low emissions of
organic HAP and requiring proper combustion is the best means of control.

Response to Comment 35: The EPA acknowledges the support and has retained in the final rule a work
practice standard for organic HAP emissions.

13.	Request to modify or remove work practice standards.

Comment 36: Commenters 17638 and 17818 request that the EPA establish a work practice standard in
lieu of emission limits for organics and dioxin/furans. Commenters disagree with some of the individual
elements of the work practice standard, such as the 18-month work practice interval and the requirement
to inspect flame patterns as a means of determining optimized combustion. Commenter 17818 further
states that conducting burner inspections will often include a requirement to install scaffolding in the
furnace, to gain access to the burners, and then removal of the scaffolding. According to the commenter,
this is a process that is both expensive and time consuming, as well as generally not required except to
perform burner inspections or perform repairs, and such activities are generally not done on an annual
basis, but rather are less frequently performed during periods of extended maintenance
shutdown/inspection. Commenters proposed that the 18-month maximum outage interval should be
extended to 24-30 months and the inspection of flame patterns for EGUs for the purpose of tuning
burners is improper. EGUs can have 50 or more types of burners, and not all flames are visible.

468


-------
Inspecting flame patterns is more useful for industrial boiler practices in which an observer peers
through a glass at the burner and then makes changes to nearby controls to optimize the flame.
Commenter 17638 supports a CAM-type approach regarding the establishment of work practices, which
provide for reasonable assurance of the unit operation in lieu of a "one size fits all" approach.

Several commenters (17689, 17756, 17928, 17813) state that the 18-month interval between inspections
is not consistent with established utility practice regarding periodic outages for maintenance and repair.
Commenters recommend a 36 month compliance period. According to the commenters, utilities should
be able to implement their own best management practices if they are demonstrated to be best for the
unit. For small systems, such as many rural electric cooperatives, state the commenters, many parts may
not be inventoried and may take several months to acquire, and to complicate matters, units may be in
periods of high need, such as during summer or winter peaking when replacement parts become
unavailable, thus making shutdown for repair not feasible due to reliability or other paramount concerns.
In such cases, commenter 17689 believes utilities should be given reasonable time to optimize
considering the electric demands on the system.

Commenter 17756 states that the work practice standards for EGUs to address any emissions of
organic HAP and dioxins do not reflect some of the practical realities of operating an EGU.

Several commenters (17761, 17767, 17795) state that the proposed work practice standards regarding
organic HAP will have a detrimental impact on the outage schedules of applicable units since every unit
would have to perform an onerous inspection and tune-up every 18 months. According to the
commenters, this scheduled tune-up would require additional outages in between planned major
maintenance overhauls further affecting unit availability, overall system reliability, and generating costs.
The commenters state that the EPA's ICR test data demonstrated that the majority of applicable units
emitted non-detectable levels of organic HAP, even under the utility industry's existing work practice
standards and maintenance outage cycles. Commenters 17761 and 17795 suggest that there is no need
for increased scheduled outages and inspections (every 18 months) for units already emitting non-
detectable levels of these HAP and, as such, these standards should be removed from the final rule.
Commenter 17767 recommends an extension beyond 18 months.

Commenter 17851 states that the EPA should not set a dioxin/furan standard or a non-dioxin organic
HAP standard. Doing so will not reduce the emissions of organic HAP.

Commenter 17851 states that the EPA should not set a dioxin/furan standard or a non-dioxin organic
HAP standard and that doing so will not reduce the emissions of organic HAP.

Commenter 17930 states that the EPA should allow utilities to document their own operating practices,
including testing, data collection, and inspection schedules. According to the commenter, each utility
has developed documentation practices that best, and most efficiently, serve that particular plant and
company and to require other documentation practices would be an unnecessary burden on already taxed
utility operators. The commenter states that there are many instances where emissions are below
detection levels and should not be used as a basis to establish a work-practice standard.

Several commenters (19536, 19537, 19538) states that the work practice standard should require that all
EGUs install real-time software to continuously optimize boiler combustion and perform soot cleaning.
According to the commenter, these systems continuously monitor the combustion process to determine
the optimal balance of fuel and air flows in the furnace to position dampers, burner tilts, overfire air and
other controllable parameters at their optimal setting. The commenter states that these systems are

469


-------
already in widespread use throughout the utility industry and have the added benefit of improving
efficiency, thus reducing operating costs. According to the commenter, a boiler tune-up is not adequate
to assure continuous minimization of organic HAP. The commenter asserts that the work practice
standard assumes that all organic HAP are created by incomplete combustion and that this assumption is
incorrect, especially for dioxins which are formed after the combustion process and whose emission rate
depends in part of coal chlorine content.

Response to Comment 36: The EPA has reviewed the comments on the proposed frequency of tune-
ups, and made adjustments in the final rule. Under the final rule, the tune-up must be conducted at each
planned major outage and in no event less frequently than every 36 months, with an exception that if the
unit employs a neural-network system for combustion optimization during hours of normal unit
operation, the required frequency is a minimum of once every 4 years (48 months). The EPA believes
the minimal recordkeeping associated with this work practice standard is not unduly burdensome. The
EPA does believe that a work practice standard is the best approach for controlling organic HAP, and
thus has retained the work practice standard in the final rule.

14. Delegation to states (compliance dates).

a. General support.

Comment 37: Commenters 17758 and 17909 indicate that allowing states to seek delegation of the
section 112 program will provide important compliance flexibility (particularly related to timing of
retirements, repowerings, and installations of control equipment) for those units and utilities that have
already made investments consistent with state environmental programs, and failure to allow state
delegations could undermine these investments. Commenter 17758 further indicates that if states can
demonstrate that overall emissions reductions are equivalent or greater than those that would be
achieved by the proposed rule, the EPA should delegate the section 112 program to these states, even if
the state emissions reductions would not necessarily occur on the same schedule.

Commenter 17798 states that the EPA needs to be aware that states with existing Hg rules may request
approval of their rules in meeting the EGU NESHAP. According to the commenter, to this point,
Wisconsin, under state statute, is required to establish state rules for implementing any federal NESHAP
requirement. Commenter requests the EPA to include a process in the NESHAP rule which will
facilitate states in establishing rules as equivalent to the EGU NESHAP. For Hg emissions and other
accumulative impact pollutants, the commenter suggests equivalency can be measured by comparing
total emissions on a statewide or corporate utility basis.

Commenter 17719 is concerned about existing sources subject to state-only rules for the reduction of Hg
and other air toxic emissions. Commenter does not want the promulgation of the MATS to undermine
the tremendous amount of work invested in creating a program to curb emissions within a reasonable
timeframe, protecting both the economic viability of the state and the health of the public. Commenter
seeks to make use of temporal flexibility, authorized under CAA section 112(i)(3) in obtaining
delegation of the MATS to preserve a hard negotiated comprehensive Colorado-specific program
designed to yield greater emission reductions than the MATS alone. The commenter states that the state
has taken three separate actions to reduce the emissions of criteria pollutants and HAP from coal-fired
utility boilers.

470


-------
a.	The Colorado Air Quality Control Commission (AQCC) adopted state-only Standards of Performance
for Coal-Fired Electric Steam Generating Units into Regulation No. 6, Part B, Section VIII on October
18, 2007;

b.	The Colorado Legislature passed House Bill 10-1365, the "Clean Air-Clean Jobs Act" ("CACJA"), on
April 19, 2010; and

c.	The AQCC adopted revisions to the Regional Haze State Implementation Plan ("RH SIP") in
Regulation No. 3, Part F on January 7, 2011.

According to the commenter, under these rules, the state has successfully negotiated both emissions
standards and shut down provisions with Colorado utilities to reduce the emission of criteria and
hazardous air pollutants on a timetable that protects the public interest. The commenter states that
the CACJA in particular resulted in extensive negotiations to ensure the reliability of the energy grid
while encouraging the use of renewable and cleaner energy sources, taking into consideration cost
impact to customers, necessary transmission system changes, unit outage schedules and outage
contingencies, and construction timeframes, and that ultimately, the CACJA will promote job growth
and reduce air emissions within the State.

Commenter 18034 states that the state agencies that receive delegated authority for the final NESHAP
rule will be tasked with enforcing the rule. According to the commenter, some of the issues will directly
impact its ability to appropriately enforce the rule, and the EPA must consider how state agencies will be
expected to enforce the rule.

Comment 38: Several Commenters (17758, 17873, 17756) state that the EPA should allow states to
seek delegation of the CAA section 112 program, as authorized by the Act. Section 112(1) of the CAA
allows a state to seek delegation of the section 112 program. The commenters note that in the proposed
rule the EPA acknowledges that a number of state and local program have plans to address
environmental issues and that these plans may lead to reductions in HAP emissions equivalent to or
greater than the proposed rule.

b. Support for specific state/local or EGU.

Comment 39: Commenter 18019 states that they encourage the EPA in the final MACT rule to make
clear that Oregon has regulatory flexibility to address the unique Boardman case. In particular, the
commenter asks the EPA to expressly recognize that Oregon could obtain delegated authority under
section 112(1) to implement the MACT consistent with the Boardman 2020 plan, where the plant will
achieve mercury reductions both ahead of and in excess of any federal standard, meet the acid gas and
organics standards in advance of the MACT requirements, and cease coal burning entirely by 2020.
Commenter urges the EPA to expand on this concept in the final rule and make clear that plans, such as
the Boardman 2020 plan, coupled with the early mercury reductions, would meet the "no less stringent"
test for state delegated programs.

Comment 40: Commenter 17867 states that early termination of coal operations and interim controls
will result in lower aggregate emissions of haze causing pollutants than those projected under a much
more expensive control package that would have otherwise been required to run the plant indefinitely in
compliance with haze-related standards. According to the commenter, the EPA's proposed
Utility NESHAP Rule is one of several the EPA rules that will affect the nation's coal fleet, including
the Boardman facility. The commenter states that the Boardman plan requires Commenter to install

471


-------
pollution controls to reduce interim emissions of NOx by about 50 percent through the installation of
advanced combustion controls, and to reduce S02 emissions through a combination of lower-sulfur fuel
and the installation of a DSI system. According to the commenter, under the Boardman 2020 plan, all
emissions associated with coal-firing at the Boardman Plant will end by 2020, resulting in dramatic
reductions in all conventional pollutants (SO2, NOx, PM), Hg, other HAP, and GHGs. In addition, the
Boardman 2020 Plan establishes a path toward significant reductions in C02 emissions in advance of
regulation by mapping a careful and reasonable transition away from coal-fired generation at this
facility. According to the commenter, the EPA regulations would require pollution upgrades in order to
meet air quality, water quality or waste management requirements, and once these regulations are
finalized, a key question facing electric utility companies is whether to retrofit and run coal units into the
future or to retire these units. The commenter states that these decisions are challenging given continued
uncertainty about federal climate policy and that the EPA could resolve this dilemma by establishing a
clear regulatory pathway that allows the state to preserve a Boardman-like plan and reconcile it with the
requirements of CAA section 112. Commenter recommends that the EPA consider providing commenter
and ODEQ specific guidance for a state plan containing the following elements, that if offered by the
ODEQ in connection with other elements needed for compliance assurance, would be considered by the
EPA as potentially meeting the equivalency requirements of section 112 and subpart E:

a.	A Hg standard more stringent and imposed earlier than the federal rule. The commenter states that the
Oregon Utility Mercury rule was promulgated in 2006 and requires Boardman to meet an aggressive
standard of removal of at least 90 percent of the Hg emitted from the unit or a limit of Hg emissions to
0.60 pounds per trillion BTU of heat input by no later than July of 2012; thus, Boardman would achieve
Hg controls that are well below the EGU MACT proposed limits and have them installed at least 3 years
early.

b.	An acid gas standard the same as, or more stringent than, the proposed federal rule. The commenter
states that to meet BART requirements for S02, PGE is installing a control package that includes
DSI technology, and anticipates the use of low sulfur coal; while installation has not been completed,
and full scale testing to determine control effectiveness has not been done, based on preliminary
evaluations, commenter believes that the DSI technology is likely to have the collateral effect of
removing acid gasses to achieve compliance with the standard.

c.	The proposed section 112 work practices standard for dioxin/furans and for the non-dioxin/furan
organic HAP. The commenter states that these are already contemplated under existing requirements for
the Boardman Plant.

d.	A slightly less aggressive limit for non-Hg metals. The commenter states that this might be either the
existing PM emission limit of 0.04 lb/MMBtu (filterable) as a surrogate for non-Hg metals or slightly
relaxed individual or total metals limits. According to the commenter, while Oregon potentially could
allow marginally higher emissions than the federal standard, the Oregon plan would require complete
phase out of fossil fuels by 2020, which would result in significantly lower aggregate non-Hg metal
emissions compared to continued operation in compliance with the MACT standard under the EGU
NESHAP proposal.

e.	A requirement that coal firing at Boardman be stopped by 2020, which would result in of the dramatic
reduction in all HAP and other pollutants. Commenter believes such a set of requirements, which would
contain some elements that are more stringent than the federal rule and others that are slightly less
stringent, would - taken as a whole - be at least as stringent as the proposed federal rule. According to
the commenter, given that delegations to date have been based on state regulations that are essentially

472


-------
identical to the federal rules or contain more stringent requirements for particular pollutants (e.g., Hg),
the EPA has not had an opportunity to provide the public with an analysis of whether an alternative state
program may allow emissions for individual pollutants to exceed by a modest amount the EPA's
emissions limits so long as the state's program obtains greater overall benefits. The commenter
considers the Utility NESHAP Rule to be the perfect opportunity for the EPA to address this aspect of
its delegation authority and provide guidance to the states regarding their demonstration of equivalency.

Commenter 18019 states that under "Boardman 2020" plan, PGE will install pollution controls to reduce
interim emissions of nitrogen oxides by about 50 percent and sulfur dioxide emissions by 75 percent.
According to the commenter, all coal-related emissions from the Boardman Plant will be reduced to zero
with the end of coal operations in 2020. The commenter states that IRP in Oregon is a rigorous process
for examining how to meet customer needs at the lowest cost and risk. According to the commenter, IRP
provides substantial opportunity for public involvement during the preparation and review of a utility's
plan; in its IRP, a utility must assess the performance of candidate resource portfolios under different
assumptions about key variables, such as load growth, fuel prices, and environmental costs that may be
incurred.

Comment 41: Commenter 17867 states that the EPA should clarify that States may demonstrate
equivalency with the EGU MACT through alternative regulation that achieves in aggregate emissions
outcomes that are equivalent to the NESHAPs. Specifically, the commenter requests the EPA to confirm
that Oregon has flexibility to use its Mercury Rule and the Boardman 2020 Plan to address federal
Regional Haze requirements as the foundation for a delegated program. The commenter states that
section 112(1) of the CAA, and the corresponding implementation regulations at 40 CFR Part 60,

Subpart E, provide that each state may develop and submit to the Administrator a program for
implementing the EPA's section 112 HAP program and that the equivalency is not a line-by-line test but
rather a demonstration that the alternatives must be holistically equivalent to the Federal requirements.
Commenter urges the EPA to make clear that a state-implemented rule for coal units that includes
steeper and/or earlier emission reductions of some pollutants (e.g., Hg), identical emission limits for
other pollutants (e.g., acid gases), and marginally less aggressive emission reductions for some
pollutants (e.g., non-Hg metals or PM), plus a commitment to early cessation of coal firing, along with
the necessary work practice standards and elements necessary for compliance assurance, may be
considered by EPA as no less stringent, i.e., "equivalent," to the proposed utility NESHAP rule.

c.	Concerns over delegation.

Comment 42: Commenter 17648 states that in response to request for comments on whether EPA
would be authorized to delegate the section 112 program to states enforcing laws related to EGU
emissions and HAP reductions where the program results in greater emission reductions than the EGU
MACT but allows a compliance time extending beyond the statutory three year maximum such
delegation would "not [be] appropriate unless the state program is at least as stringent as the federal
program." The commenter states that the law is "quite clear on this point" and that EPA "does not have
the discretion to approve a state program with more lenient deadlines."

d.	Implementation.

Comment 43: Commenter 16859 requests that the EPA concurrently publish implementation guidance
for this rule to states at the time of new rule issuance. According to the commenter, timely issuance of
implementation guidance would facilitate state adoption of the new rule as well as increase state and
EPA staff resource efficiency in completing activities related to new rule adoption.

473


-------
Response to Comments 37-43: Responses to these comments are provided in the preamble to the final
rule.

15.	Need option for percent reduction or increase compliance averaging time.

Comment 44: Commenter 17737 requests that percent reduction should be available as an alternate to a
numerical emission rate and could be established to be based on percent reduction from the boiler inlet
Hg concentration in a manner similar to the procedure under 40 CFR 60 subpart Da. According to the
commenter, the percent reduction could be set at 91 percent, which is the same level as the EPA expects
to be achieved nationwide. The commenter states that the numerical limit may be difficult if not
impossible to achieve should a source be limited to using coal with a high Hg concentration (above 13
lb/TBtu). The commenter asserts that switching coal sources may not be possible due to the presence of
long term coal contracts, mine-mouth configuration, or boiler design. If the Hg coal concentration
increases over time, Commenter may not be able to meet the standard with available technology and
could be faced with curtailment as the sole compliance option but that this concern could be somewhat
alleviated if the compliance averaging time were to be on a 12-month rolling basis.

Commenter 17737 states that ICR data shows some EGUs would achieve a lower emission rate with 75-
85 percent removal than others with removal rate in excess of 91 percent. According to the commenter,
by not including a percent removal, the EPA is penalizing those EGUs that are not able to obtain coals
with relatively low Hg content.

Commenter 17737 states that the EPA's primary rationale for not allowing the percent reduction option
is that it may discourage or complicate the use of coal washing as a compliance technology. According
to the commenter, this would only be the case if the EPA elected to adopt a percent removal standard in
lieu of a numerical limit.

Response to Comment 44: We have addressed comments related to a percent reduction format
elsewhere in the final rule record.

16.	Cannot meet mercury emission rate on continuous basis.

Comment 45: Commenter 17761 states that after a case-by-case MACT review for Hg, one of their
EGUs was expected to achieve a Hg emission rate of 1.70 lb/TBtu (an approximate 83 percent
reduction) but that stack testing and monitoring data from the facility has demonstrated significant
variability in Hg emissions. The commenter states that operating and monitoring experience with Hg
emissions at their EGU suggests that ACI performance is also highly variable and subject to decline
based on a number of factors which may necessitate the use of additional solutions to achieve the
expected performance criteria. According to the commenter, the inherently low chlorine content
of their coal will make it extremely difficult for well-controlled units that utilize their coal to meet the
proposed rule's 1.2 lb/TBtu Hg emission rate on a continuous basis. The commenter states that Hg
emissions as a function of ACI can vary dramatically over time for reasons that are either not completely
understood (e.g., effects of temperature, pressure drop, ammonia slip, SCR catalyst degradation, etc.) or
outside the utility's control (e.g., variability of Hg and chlorine content in delivered coal, variability in
delivered activated carbon surface area, etc.).

Response to Comment 45: The rule's Hg limit was established consistent with the requirements of
CAA section 112(d) and it accounts for variability. As demonstrated by contemporaneous data collected
by EGU owners or operators and submitted to the Administrator, approximately 180 EGUs are currently

474


-------
meeting the Hg standard contained in the final rule. To the extent a particular owner or operator believes
his EGU's Hg emissions are too high, he can and should take advantage of the three year period before
compliance is required to find one or a combination of mercury-reducing approaches that will enable the
EGU to meet the Hg emissions limit.

17.	Allow portable monitoring equipment.

Comment 46: Commenter 17740 requests the EPA to permit sources to measure concentrations of CO
and NOx in the effluent stream before and after adjustments with portable monitoring equipment.
According to the commenter, industry practice is to use portable analyzers located at the boiler outlet
duct to measure CO and NOx during combustion tuning operations.

Response to Comment 46: The EPA agrees with the comment and has modified the rule to allow
portable emissions monitoring equipment as acceptable for meeting this requirement.

18.	General clarifications needed.

Comment 47: Commenter 17740 states that the EPA should clarify the time ranges listed in 40 CFR
section 63.10006(n). The commenter states that the proposed ranges are specified in terms of days,
months and years, and that it is unclear whether the EPA is referring to calendar or operating days.
Commenter recommends that the EPA adopt operating days or operating quarters. The commenter states
that these terms are used routinely by utilities to manage emissions program schedules.

Commenter 19033 states that Table 3 of the the proposed regulation conflicts with 63.1 0006(o) and (p).
63.10006 provides that less frequent testing than annual may be performed, if the criteria in 63.10006(o)
and (p) are met, whereas Table 3 requires that annual testing be performed for existing EGUs. To correct
this conflict, Commenter 19033 recommends that Table 3 be amended for existing EGUs.

Response to Comment 47: The agency reviewed the commenters' concerns, clarified in section
63.10006(g) that calendar days are the appropriate measurement between stack tests, and corrected
Table 3 in the final rule. The agency finds periodic stack testing based on a time period other than
calendar days would be confusing for not only the owner or operator but also the agency and the public.
Note that the cited table was intended to refer to the annual performance tune-up in the proposed rule.
Under the final rule, this has been clarified and the periodic frequency for conducting the tune-up has
been modified. See discussion in the preamble.

19.	Opposition to the EPA regulation.

Comment 48: Commenter 17768 states that citing the justification for an emissions averaging decision
that was provided in a 16-year old rulemaking is insufficient.

Comment 49: Commenter 18477 states that Hawaii's RPS has two significant ramifications for
commenter's ability to comply with the proposed rule: first, modification of a large percentage of
commenter's generation fleet to use renewable fuel sources has the potential to substantially reduce
HAP emissions, but these modifications will not be completed prior to the EGU MACT compliance
date. Second, states the commenter, compliance with both the Hawaii RPS and the EGU MACT will
require massive capital investments, and it would be unfair to require commenter and its customers to
invest in both, particularly when current resource plans indicate the retirement of at least four EGUs
with relatively low capacity factors within eight to ten years. According to the commenter, installation

475


-------
of costly control technology on these units to comply with the EGU MACT for the relatively short time
frame before retirement would also represent significant economic inefficiency. Commenter estimates
that installation of emission control equipment for Hg, HC1, HF, and PM would cost at least $696
million, based on preliminary quotes provided by engineering consultants and equipment vendors.
According to the commenter, to date, no control equipment vendor will provide performance guarantees,
so this cost estimate does not address the risk associated with failure to comply with the proposed HAP
emission limits. The commenter states that it is extremely difficult for companies to develop a cost-
effective compliance plan without control equipment vendor guarantees. Vendor guarantees allow
companies to plan for prudent capital investments in control technology. Without these guarantees,
Commenter is facing the untenable possibility that it will not be able to comply with the proposed
standards despite the Company's best efforts and significant capital investments. Accordingly,
Commenter urges the EPA to exercise its discretion and establish work practice standards for non-
continental liquid oil-fired units.

Comment 50: Commenter 17805 states that it is inappropriate for the EPA to require utilities to expand
energy efficiency and demand response programs as an alternative to replacing retired generation when
retrofits are uneconomical. The commenter states that based on their resource modeling, the
effectiveness and long-term viability of these programs are ultimately dependent on customer
participation. According to the commenter, demand response and energy efficiency programs are
typically more suited to be replacements for peaking type generation resources than traditional base load
generation.

Response to Comment 48 - 50: The EPA disagrees that established precedent, can and should not be
used as justification for actions within this rulemaking. As noted elsewhere in this document, we have
established a subcategory for non-continental liquid oil-fired EGUs in the final rule. Responses to
comments related to the compliance date and emissions averaging are provided in the preamble to the
final rule and elsewhere in the final rule record.

476


-------
CHAPTER 6: IMPACTS AND COST ANALYSIS

6A - Impacts/Costs: Emission Impacts
Commenters: 17174, 17385, 17620, 17689, 17768, 18932

Comment 1: Commenter 17174 asks that the EPA take into consideration the effect of the proposed rule
on non-HAP pollutants and the overall air quality and public health improvement to avoid exacerbating
air quality issues.

Response to Comment 1: The EPA has determined that the proposed rule will lead to reductions of
criteria and HAP responsible for significant adverse health effects and that such reductions will produce
substantial public health benefits. Accounting for ancillary impacts is standard practice in benefit-cost
assessment since these benefits are a consequence of the rule, regardless of the rule's intended purpose.
This rule is expected to achieve substantial PM2.5 health benefits resulting from primary PM and SO2
emission reductions, and these co-benefits have been included in the regulatory impact assessment.

Comment 2: Commenter 17385 asks that the EPA perform additional energy efficiency sensitivity
analyses incorporating additional policies. The commenter is pleased with the Integrated Planning
Model (IPM) analysis of demand-side energy efficiency impacts on moderating electricity demand and
reducing compliance costs. The IPM performed for the proposed rule included only federal appliance
standards and utility demand side management programs. The commenter points out that there are other
efficiency programs that could be factored in, such as building codes, tax incentives, state and local
programs.

Response to Comment 2: The EPA recognizes that the energy efficiency sensitivity conducted does not
represent the full array of ongoing policies in this area. The scenario does, however, illustrate in detail
the impacts of two of the more significant policy types that are leading to increased investment in end-
use efficiency: ratepayer-funded programs and federal appliance standards. These policies are not
otherwise represented, for the most part, in the baseline electricity demand forecast from EIA that is
used in the EPA's modeling. Building codes and tax incentives may be accounted for to a greater degree
in the EIA forecast.

Comment 3: Commenter 17620 argues that although the proposed rule would reduce Hg emissions so
that on average the remaining emissions could be approximately 45 lb/unit, emissions of 22 lb/yr/unit
cannot be considered trivial or "de mimimis."

Response to Comment 3: The EPA disagrees with the commenter's notion that the goal of the
technology-based phase of regulation under CAA section 112 is to reduce emissions to levels that can be
considered trivial or "de minimis." In fact, there is no such goal described in all of CAA section 112 and
today's rule complies with the requirements of section 112(d) to establish technological standards based
on what has been achieved in practice by the best performing sources in the category. If the commenter
is actually commenting on whether the proposed regulation will adequately protect public health or not,
under the requirements of CAA section 112(f), within 8 years after promulgation of this rule, the EPA
will determine whether additional regulations are necessary to further limit HAP emissions from EGUs
to protect public health with an ample margin of safety.

Comment 4: Commenter 17689 reports that generating and transmission cooperatives provide 41% of
all distribution cooperative electric generation needs, of which 80% is coal-fired. The commenter also

477


-------
states that 50% of this coal-fired equipment was constructed under CAA NSPS and more than 60% has
FGD or scrubbers to control S02 emissions. Also, more than 6,000 MW of the generating capacity has
been retrofit with NOx controls, and SCR. Nearly all of the equipment has low NOx burner technology,
making the aggregate cooperative coal-fired generation newer and better controlled than the overall
electric utility sector.

Response to Comment 4: Existing pollution control technologies are available for EGUs to comply
with MATS, including controls that reduce Hg, non-Hg metal and and particulates, and acid gas HAP,
including HC1.

Comment 5: Commenter 17768 states that the rule is justified based on the co-benefits that stem largely
from PM reductions which represent the majority of total quantified and monetized benefits. The
commenter argues that is important to account for such co-benefits or ancillary benefits because they are
just as significant as countervailing risks and they help to justify the cost-benefit analysis for the
regulation.

Response to Comment 5: The EPA agrees that it is valuable to quantify the PM2.5 health co-benefits of
this rule. Accounting for ancillary benefits is standard practice in benefit-cost assessment since these
benefits are a consequence of the rule, regardless of the rule's intended purpose. The EPA estimates all
of the anticipated costs and benefits associated with a regulatory action, to the extent feasible, for the
purpose of determining the likely impacts, not to justify an action. This rule is expected to achieve
substantial PM2.5 health benefits resulting from primary PM and SO2 emission reductions, and these co-
benefits are thus an important category to quantify.

Comment 6: Commenter 18932 cites that in 2005 EGUs were responsible for 47% of anthropogenic
cobalt emissions in the US. The commenter then cites the negative health impacts of cobalt emissions.

Response to Comment 6: Cobalt emissions will be regulated under the provisions of this rule. Under
the requirements of CAA section 112, within 8 years after promulgation of this rule, the EPA will
determine whether additional regulations are necessary to further limit emissions of cobalt (or any other
HAP) to protect public health with an ample margin of safety.

Comment 7: Commenter 17627 states that the 2005 base year did not include emission reductions that
have already occurred as a result of many enforceable federal and state programs. Additionally, the 2016
emissions are predicated off the IPM related NODA dated October 2010 and do not include results from
two subsequent NOD As. If the emission estimates were corrected the benefits would not be overstated
and it is possible that the rule could not be justified on cost considerations.

Response to Comment 7: The EPA disagrees with the commenter's assertion that the benefits are
overstated based on a 2005 base year. The benefits of the rule are computed based on differences
between the 2016 baseline and the 2016 policy case, and not the differences from 2005. Therefore, to
achieve reasonably accurate estimates of benefits, the most important feature of the EPA's approach is
having an accurate projection from 2005 to 2016, so that the emissions reductions and economic
downturn referenced by the commenter are included in the future base and therefore not included as part
of the benefits of the rule. These impacts are included in both the 2016 baseline and the 2016 policy case
and therefore are not captured as benefits of the rule. The EPA diligently included the emissions
reductions that have occurred from 2005 to present and the final modeling done for the RIA for this rule
is the best available national information to reflect reductions in emissions that have occurred from 2005
to present. The data used at proposal were updated to reflect the comment process on the Cross-State Air

478


-------
Pollution Rule (CSAPR), for which number eastern states provided detailed updates to the EPA's
emissions projection assumptions for EGU, non-EGU point, stationary area, and non-road mobile
sources. All of these comments were included in the projections used for this final rule. Furthermore, the
comment process for this rule provided an opportunity to make the EPA aware of any other projection
changes that were needed for improving our benefits estimates. In the rare instances where such specific
comments were made for this rule, the EPA included those reductions in the final 2016 projections. The
EPA used the best economic forecasts available at the time the datasets were created. This included the
use of Annual Energy Outlook (AEO) of 2010 data in the EGU projections. Other updates to point
sources included the incorporation of all known controls in the 2016 baseline, and the inclusion of non-
EGU plant closures, federally enforceable emissions reductions, and consent decrees that have happened
since 2005. Finally, while the EPA has attempted to provide the most reliable and accurate assessment
of the costs and benefits expected to result from implementation of the rule, the commenter incorrectly
assumes that the rule must be justified on the basis of cost.

479


-------
6B - Impacts/Costs: Emission Reductions

Commenters: 17716, 17807, 17884, 17916, 18037, 18425, 18428, 18434

Comment 1: Commenterl7716 expresses concern that the EPA's real objectives of imposing the
proposed rules is to retire "some of the oldest, least efficient, least controlled units" from further
generation and virtually dictates that these units be retired. The commenter states that the EPA's claim
that compliance options to reduce criteria pollutants would not have HAP reductions lacks evidentiary
foundation. Further, HAP emissions by EGUs have yet to be linked to a cognizable hazard.

Response to Comment 1: The EPA disagrees with the commenter's assertions regarding the motives
underlying MATS and the lack of a linkage between HAP emissions by EGUs and public health
hazards. The EPA's full statement found in the preamble to the proposed rule does not imply that the
EPA encourages or requires EGUs to retire rather than install control equipment but, rather, simply
observes that if companies choose to retire the units, it is unlikely to have notable impacts on electricity
grid reliability (as shown by EPA analysis). EPA did not state that compliance options for criteria
pollutants will not reduce HAP emissions as commenter suggest, only that there may be compliance
options (e.g. purchasing allowances in a trading program) which may not lead to HAP emission
reductions. We direct the commenter to Section III of the preamble to the final rule for a discussion of
the hazards to public health and the environment attributable to EGUs.

Comment 2: Commenter17904 suggests the EPA account for reductions in emissions that have
occurred since 2000, and for other expected continuing reductions driven by state and other CAA
requirements. The commenter discusses the 26% reduction in annual S02 emissions and 62% in NOx
emissions from Texas EGUs from 1995 to 2009 and the fact that nearly 50% of the coal-fired capacity in
Texas has FGD systems. The commenter also points out that national concentrations of PM2.5 and PMi0
have dropped 21-30%.

Response to Comment 2: As discussed in the preambles to the proposed and final rules, the EPA agrees
that it is appropriate to account for emission reductions achieved by other requirements of the CAA, and
the EPA has done so in the technical analyses accompanying this final rule. As documented in multiple
technical support documents supporting the final rule, the EPA acknowledges that emissions from U.S.
EGUs and other sources would be less than previous years due to controls applied to comply with other
EPA regulations. It is standard practice for the EPA to include these emission reductions achieved
through promulgated regulations, settlements, consent decrees, and closures in the baseline for future
year analyses. Because the CSAPR has significant impacts on emissions from U.S. EGUs, the EPA
specifically accounted for CSAPR in the baseline. As such, the EPA has accounted for emissions
reductions since 2000 in the analyses supporting the "Appropriate and Necessary" finding, as the
commenter suggests. Future year emissions modeling conducted for the final RIA was updated to reflect
the most recently available information, and incorporates comments submitted to the docket in response
to the proposed rule.

Comment 3: The U.S. relies on coal-fired generation for about half of its electricity. It should be taken
into account that the U.S. power sector has reduced air emissions substantially under existing programs.
The industry has cut S02 and NOx emissions by 57% since 1980. Mercury has been cut by 40%. This
has occurred while electricity use has increased by 85% and electricity from coal generating facilities
has tripled. The industry has made significant strides to reduce emissions. Derailing such efforts by
piling on additional regulations that many coal- and oil-fired facilities are not able to comply with
undermines all this hard work. Not only does the proposed Utility MACT rule in its current form

480


-------
threaten existing generating facilities, it threatens future development of an integral part of our energy
portfolio. Please withdraw this proposal.

Response to Comment 3: This regulation does not conflict or interfere with efforts cited by the
commenter, but rather builds on them by requiring that coal-fired power plants control highly toxic HAP
emissions to a level that is currently being achieved by the best performing EGUs. These levels of
control can be achieved with the application of widely available cost effective pollution control
equipment and practices. Doing so will save thousands of lives and avoid hundreds of thousands of
cases of illnesses including asthma attacks and other respiratory symptoms in children.

Comment 4: Commenter 18037 believes the use of base year 2005 overstates emission reductions from
the proposed rule because it ignores the additional reductions realized between 2005 and the present.
The commenter also suggests the future emissions are erroneous because they are based on 2010 NODA
that have since been updated. Finally, the commenter states that the economic downturn that began in
2008 further reduces actual emissions, making the benefits of the proposed rule less than predicted.

Response to Comment 4: The EPA disagrees with the commenter's assertion that the benefits are
overstated based on a 2005 base year. The benefits of the rule are computed based on differences
between the 2016 baseline and the 2016 policy case, and not the differences from 2005. Therefore, to
achieve reasonably accurate estimates of benefits, the most important feature of the EPA's approach is
having an accurate projection from 2005 to 2016, so that the emissions reductions and economic
downturn referenced by the commenter are included in the future base and therefore not included as part
of the benefits of the rule. These impacts are included in both the 2016 baseline and the 2016 policy case
and therefore are not captured as benefits of the rule.

As discussed in the preamble to today's rule and supporting materials, the EPA diligently included the
emissions reductions that have occurred from 2005 to present and the final modeling done for the RIA
for this rule is the best available national information to reflect reductions in emissions that have
occurred from 2005 to present. The data used at proposal were updated to reflect the comment process
on the CSAPR, for which number eastern states provided detailed updates to the EPA's emissions
projection assumptions for EGU, non-EGU point, stationary area, and non-road mobile sources. All of
these comments were included in the projections used for this final rule.

The EPA used the best economic forecasts available at the time the datasets were created. This included
the use of AEO of 2010 data in the EGU projections. Other updates to point sources included the
incorporation of all known controls in the 2016 baseline, and the inclusion of non-EGU plant closures,
federally enforceable emissions reductions, and consent decrees that have happened since 2005. Benefits
of the rule are based on emissions reductions projected by IPM modeling to occur in 2016. These
projections are based on demand assumptions in 2016 consistent with AEO 2010. The EPA thus
disagrees with commenter, and maintains that benefits are not overstated as a result of the economic
downturn. See IPM documentation Chapter 3 for further details on electricity demand.

Comment 5: Commenter 18428 discusses well-controlled facilities which have installed control
technology that reduces their emissions to area source levels. The commenter believes that applying
generally achievable control technology (GACT) to these facilities recognizes the investment already
made.

Response to Comment 5: The EPA has addressed comments relating to area sources elsewhere in the
preamble to today's rule as well as other portions of this document.

481


-------
Comment 6: Commenter 18434 states that the proposed rule's output-based emissions limits appear to
consider only electrical output, which fails to account for thermal energy produced and used by
cogeneration units. The commenter points out that combined heat and power (CHP) and waste heat
recovery (WHR) units provide emission-free electricity and efficient heat, making a CHP twice as
efficient as traditional power generation and WHR able to produce emission-free power from heat that
would have been vented. The commenter provides a figure showing that as much as 63% of total energy
inputs are lost as wasted heat with conventional generation so the rule should incentivize CHP and WHR
projects by modifying the output-based emissions limits to account for both thermal and electric
generation.

Response to Comment 6: The final rule provides 75% credit for thermal output in the definition of
"gross output" (this is the value that was proposed). This value has been increased in the NSPS from the
original 50% credit a few years ago to recognize the environmental benefit of CHP and has been carried
over to the NESHAP.

Comment 7: Commenter 17807 disagrees with the EPA's projection that Polk Power Station Unit 1 CA
and Unit 1 CT, which use the IGCC process, would require installation of fabric filters as a result of the
proposed rule. The commenter claims that the IGCC process is extremely effective for the removal of
PM and that the fabric filter would not be warranted. The commenter requests that the EPA perform an
additional review of the modeling process and consider that fabric filters are not feasible technology for
the IGCC process and that the technology will not result in emission reductions.

Response to Comment 7: The EPA agrees that fabric filters are not a feasible technology for the IGCC
process. Final IPM modeling does not reflect the addition of a fabric filter to IGCC units.

Comment 8: Commenter 17916 supports the proposed rule because it will result in reductions of Hg and
other air toxics and criteria air pollutants that cross the national boarder into Ontario. The commenter
also cites negative health impacts of such transboundary air pollution.

Response to Comment 8: The EPA thanks the commenter for their support.

Comment 9: Commenter 18425 supports the compliance schedule of the proposed rule because
reductions in Hg emissions from Wisconsin's largest utility WE Energies will reduce health impacts to
the state's residences.

Response to Comment 9: The EPA thanks the commenter for their support.

Comment 10: Commenter 17884 agrees with the National Mining Association comments and points out
that even the EPA's own RIA shows that most of the benefit of the proposed rule will come from
reducing SO2 emissions, and ambient PM2.5, rather than HAP. The commenter also believes that the
EPA exaggerates the PM2.5 emissions, which are already addressed under other CAA programs.

Response to Comment 10: The EPA disagrees with this commenter that PM2.5 health co-benefits
should be excluded in the estimation of benefits expected by MATS. Accounting for ancillary benefits is
standard practice in benefit-cost assessment since these benefits are a consequence of the rule, regardless
of the rule's intended purpose (as noted also by Commenter 17768). As such, the EPA estimates all of
the anticipated costs and benefits associated with a regulatory action, to the extent feasible, for the
purpose of determining the likely impacts, not to justify an action. This rule is expected to achieve

482


-------
substantial PM2.5 health benefits resulting from primary PM and SO2 emission reductions, and these co-
benefits are thus an important category to quantify.

Consideration of ancillary benefits in benefit-cost analysis is directed by OMB Circular A-4 (p. 26,
available at: http://www.whitehouse.gov/omb/circulars a004 a-4/):

"Your analysis should look beyond the direct benefits and direct costs of your rulemaking
and consider any important ancillary benefits and countervailing risks. An ancillary
benefit is a favorable impact of the rule that is typically unrelated or secondary to the
statutory purpose of the rulemaking (e.g., reduced refinery emissions due to more
stringent fuel economy standards for light trucks) while a countervailing risk is an
adverse economic, health, safety, or environmental consequence that occurs due to a rule
and is not already accounted for in the direct cost of the rule (e.g., adverse safety impacts
from more stringent fuel-economy standards for light trucks)."

It is also directed by the EPA's Guidelines for Preparation of Economic Analyses (p. 11-2, available at:
http://vosemite.epa.gov/ee/epa/eed.nsf/pages/Guidelines.htmn:

"An economic analysis of regulatory or policy options should present all identifiable
costs and benefits that are incremental to the regulation or policy under consideration.

These should include directly intended effects and associated costs, as well as ancillary
(or co-) benefits and costs."

In line with this guidance, the EPA estimates all of the anticipated costs and benefits associated with a
regulatory action, to the extent feasible. We further note that we were unable to monetize other
important benefits, including health benefits of ozone reductions, additional PM2.5 health benefits, and
direct health benefits of reducing SO2. If we were able to fully monetize these benefits, the benefits
would exceed the costs by an even greater amount than we currently estimate.

The EPA disagrees that the quantified PM2.5 health benefits are double-counted with the health benefits
achieved by other regulations. The EPA's standard practice for its rules is to estimate, to the extent data
and time allow, all benefits of the emissions reductions achieved by a rule beyond control requirements
for other rules. If this rule was duplicative with other rules, then there would be no additional costs or
benefits attributable to this rule.

When the EPA estimates the benefits for rules like MATS, the EPA includes other rules such as the
CSAPR in the "baseline." Any emission changes expected as a result of MATS are additional emission
reductions beyond those regulations (e.g., CSAPR) that were considered to be part of the baseline.
Therefore, the benefits from particle reductions are not double counting - they are real additional health
benefits from emissions reductions achieved by MATS alone.

Further, the PM2.5 health benefits expected from this rule are not double-counted with benefits estimated
in the NAAQS RIAs. The NAAQS RIAs illustrate the potential costs and benefits of attaining a new air
quality standard nationwide based on an array of emission control strategies for different sources. In
short, NAAQS RIAs hypothesize, but do not predict, the control strategies that states may choose to
enact when implementing a NAAQS. The setting of a NAAQS does not directly result in costs or
benefits, and as such, the NAAQS RIAs are merely illustrative and are not intended to be added to the
costs and benefits of other regulations that result in specific costs of control and emission reductions.

483


-------
However, some costs and benefits estimated in this RIA account for the same air quality improvements
as estimated in the illustrative PM2.5 NAAQS RIA.

In implementing these rules, emission controls may lead to reductions in ambient PM2.5 below the PM
NAAQS in some areas. It is important to emphasize that NAAQS are not set at a level of zero risk.
Instead, the NAAQS reflect the level determined by the Administrator to be protective of public health
within an adequate margin of safety, taking into consideration effects on susceptible populations based
on the scientific literature available at the time the standard is set. Although benefits occurring below the
standard may be less certain than those occurring above the standard, the EPA considers them to be
legitimate components of the total benefits estimate.

484


-------
6C - Impacts/Costs: Energy Impacts

Comments are addressed elsewhere in this document.

485


-------
6D - Secondary Impacts

Commenters: 15002, 17810, 17833, 17852, 17868, 17928, 18447, 18477

Comment 1: Commenter 15002 states that while health benefits are the main reason for supporting the
proposed rule, they also recognize secondary impacts including improved quality-of-life due to positive
effects on crops, plant life, and visibility.

Response to Comment 1: The EPA welcomes this comment and concurs that, although not quantified
for this regulation, agricultural, ecological, and visibility benefits are a likely outcome of any action that
results in reduced emissions of Hg, PM2.5, or other pollutants.

Comment 2: Commenter 17868 notes the possibility of unintended consequences of the proposed rule.
For instance, utilities using eastern coal varieties may not be able to meet the requirements and will
become more reliant on rail transportation to move western coal to more power plants. Some customers
are captive rail customers who must rely on a single railroad to deliver their products. These customers
tend to need bulk commodities such as coal, grain or lumber moved, which cannot be moved effectively
on-road. The commenter references a study by the Surface Transportation Board (STB) that showed
44% of all tonnage shipped by freight rail is captive, which allows the railroad industry to charge rates
500 to 700% above cost and refusing to provide adequate service to shippers who are captive to one
railroad. The commenter provided the following site for more information:

http://www.railcure.org/about/about customer.asp. These increased transportation costs resulting from
fuel switching from eastern to western coals may be a reasonable secondary impact that has not been
considered.

Response to Comment 2: The EPA modeling fully accounts for the cost of rail transportation, including
a consideration of rail competition. This is reflected in the results presented in the RIA. In recent years,
railroads have increased coal transportation rates in real terms wherever they have the opportunity.
However, rail rates at plants captive to a single rail carrier are now close to the maximum levels
prescribed by the STB, which limits the potential for further real increases in these rates. Moreover,
between 2004 and 2008, the differential between rates at captive plants and rates at competitively-served
plants narrowed. For further information, please see IPM Documentation Chapter 9.3 ("Coal
Transportation").

Comment 3: Commenters 17810 and 17852 recognize that the EPA can include non-air quality health
and environmental impacts in evaluating beyond-the-floor options, but could not find any reference in
the preamble or docket addressing the uncertainties meant in the preamble wording, "[a]s discussed
above, the uncertainties associated with non-air quality health and environmental impacts also argue
against determining that fuel switching is a reasonable beyond-the-floor option." The commenters note
that strong regulatory programs exist at the federal and state levels to protect against non-air quality
health and environmental impacts from the production, transport and use of natural gas. Commenter
17852 states that natural gas does not involve issues as complex as those associated with nuclear waste
disposal or the risks associated with nuclear accidents, the environmental damage from mountaintop
coal, the technical complexity of offshore deep water oil drilling or the need for new high-voltage, long-
distance transmission or large land footprints needed for utility-scale renewable energy. This commenter
goes on to say that the EPA's record shows that non-air issues apparently do not provide a reasonable
basis to discourage fuel switching from coal to natural gas.

486


-------
Response to Comment 3: The primary basis for EPA's rejection of fuel switching to natural gas was
that the switch would not be cost effective, not because of the non-air quality health and environmental
impacts. We do note, however, that natural gas extraction through hydraulic fracking is a relatively new
process and, while it can be safely undertaken, there remains some level of uncertainty about the level of
expertise available to do so in all instances.

Comment 4: Commenter 17833 expresses concern that the proposed rule may impair the reuse of coal
combustion residuals (CCR) such as flue gas desulfurization gypsum (FGD gypsum). The commenter
urges the EPA to achieve emissions reductions without affecting the FGD gypsum market and points out
that ignoring the implications of the proposed rule on CCR, the cost/benefit analysis is incomplete and
cannot be properly evaluated. The commenter explains that the use of FGD gypsum to manufacture
wallboard rose dramatically since 1995 in part because of the >$1.5 billion expansions and retrofittings
done in 1999 to wallboard plants. That investment turned over 85 million short tons of FGD gypsum
into building material, and kept it out of landfills. In order to be used by most wallboard plants, FGD
gypsum must be formed in a multistage process to precise specifications by the electric utilities.
Converting operations to handle a different gypsum material requires plant closure and expensive re-
commissioning of the plant, as well as additional costs for transporting natural gypsum, which can
approach the cost of the final product. The commenter discusses the 30 years the FGD gypsum industry
has spent reviewing literature and performing their own studies to be sure the it does not present human
health or environmental concerns and provided the following references: Jessica Sanderson et al., "Fate
of Mercury in Synthetic Gypsum Used for Wallboard Production," USG Corp. Report for U.S.
Department of Energy (Aug. 2005); Lisa Yost et al., "Lack of Complete Expansive Pathways for Metals
in Natural and FGD Gypsum," 16 Human & Ecological Risk Assessment 317-39 (2010); Scott Shock et
al., "Evaluation of Potential for Mercury Volatilization from Natural and FGD Gypsum Using Flux
Chamber Tests," 43 Envtl. Science & Technology 2282-87 (Feb. 2009). Gypsum Association's
November 19, 2010 comments on EPA's proposed coal ash waste rule: "Hazardous and Solid
Management System: Identification and Listing of Special Wastes; Disposal of Coal Combustion
Residuals from Electric Utilities, Comments Submitted by the Gypsum Association." The commenter
states that the loss of FGD gypsum in the manufacture of wallboard would reverse the economic benefits
of the last 10 to 15 years and would trigger major market disruption, job loss and price increases at a
time when construction industry is vulnerable and reverse the proven environmental benefit of FGD
gypsum wallboard.

Response to Comment 4: The EPA does not expect a significant impact on the availability of FGD
gypsum due to MATS. IPM analysis shows a potential 6 GW reduction in wet FGD operations, not all
of which produce gypsum. This is a small fraction of the total 180 GW of wet FGD projected to operate
in the base case, and should have an insignificant impact on the availability of FGD gypsum.

Comment 5: Commenter 17833 sees a lack of information on the potential environmental and economic
impacts of these emission limits on the materials and waste streams that would be generated by EGUs to
achieve regulatory compliance to be problematic. Without such information the commenter believes the
EPA has not performed an appropriate cost-benefit analysis. In particular, the commenter points out that
the proposed rule may affect metal levels in EGU wastewater and waste streams. Such downstream
impacts must be addressed to adequately assess the costs and benefits of the proposed rule. The
commenter believes the narrow scope of each separate media review prevents the EPA from properly
assessing the costs-benefit ratio and the proposed rule's potential to complicate or compromise the
effectiveness of other proposed rules, and asks that the rules be considered in aggregate.

487


-------
Response to Comment 5: Waste streams associated with conventional emission controls for NOx, SO2,
and PM are already well regulated, and the costs of compliance with those regulations were considered
as part of the promulgation of those rules. MATS may increase the number of waste streams that will
have to be properly managed from two MATS-specific controls: ACI for Hg control, and trona DSI for
HC1 control. The EPA's IPM modeling for MATS includes additional solid waste landfill disposal cost
allowances as part of the variable O&M expenses associated with these controls. The EPA believes that
adequate additional waste stream related costs were assigned in the IPM modeling, and, therefore, in the
benefit/cost assessment of the MATS rule as well. The EPA is not aware of, and commenter has not
provided any information about, any waste streams associated with potential future regulations that
cannot be properly evaluated as physically distinct systems, not complicated or compromised by the
waste streams already considered for MATS and other existing rules.

Comment 6: Commenter 18447 states that the proposed rule has the potential to force their city to find
an expensive landfill solution for its municipal solid waste as an alternative to burning it.

Response to Comment 6: There are multiple options for controlling HAP to the levels required by the
final rule and the final regulation does not preclude the use of refuse-derived fuel, nor does the
regulation require conversion from coal to gas. Each EGU is able to employ the control strategy that is
best suited for that EGU, and there are various pollution controls that can be utilized to reduce emissions
without requiring a new fuel source.

Comment 7: Commenter 17928 argues that the higher the level of Trona injection the more CO2 is
produced from reactions with flue gases. The commenter states that, as will the forced oxidation wet
limestone FGD operations, the use of Trona may result in the need for additional air permits, and urges
the EPA to review and develop permitting procedures to assist in streamlining any permitting delays.

Response to Comment 7: The EPA is aware of the concern that installation of dry sorbent injection
(using trona) or some other FGD technologies will result in increased hourly emissions of CO2. The
EPA is currently designing emission guidelines for fossil-fired electric generating units and is taking this
into consideration.

Comment 8: Commenter 18477 discusses the Hawaiian RPS laws that may be undermined by the
numeric limits in the proposed rule. The commenter explains that Hawaii is moving toward having 70%
of its energy use come from clean energy sources by 2030. The commenter explains that the proposed
rule will cause Hawaii to prioritize installing controls over investments to increase clean power sources.
The commenter describes the Hawaii Clean Energy Initiative designed to implement a fundamental and
sustained transformation in the way renewable energy and energy efficiency resources are planned and
used in the state. The states RPS law requires that utility sales consist of 15% renewable energy by 2015,
25% by 2020 and 40% by 2030. A main part of the state's strategy to achieve these goals, the
commenter explains, is the use of liquid biofuel from renewable sources, which also leads to a
substantial reduction in emissions. The commenter asks the EPA to establish work practice standards so
that Hawaii has the flexibility to incorporate biofuels and biofuel blends into its power plant operations.

The commenter explains that Hawaiian Electric is a regulated entity that serves an isolated grid, so it
does not have economic resources like those available to a merchant generator which can sell power to
the highest bidder. The commenter believes the capital investment into control technologies that may not
be enough to achieve compliance will impact the ability to continue to implement the biofuels plan and
will undermine the environmental benefits of the current plans.

488


-------
Response to Comment 8: As explained elsewhere in the preamble to today's rule and in this document,
based on comments received, the EPA is finalizing a non-continental subcategory for liquid oil-fired
EGUs. We believe that this will help address the concerns noted by commenter. The EPA is finalizing
emission limitations for this subcategory because it does not believe that work practice standards are
applicable in this case as emission testing is feasible and, thus, the provisions of CAA section 112 (h)
are not met.

489


-------
6E - Impacts/Costs: Compliance Costs

Commenters: 16705, 16850, 17003, 17055, 17055, 17174, 17254, 17297, 17400, 17403, 17408, 17627,
17629, 17638, 17648, 17681, 17689, 17697, 17701, 17702, 17707, 17716, 17718, 17731, 17732, 17743,
17751, 17752, 17753, 17758, 17761, 17765, 17775, 17791, 17797, 17810, 17813, 17815, 17816, 17824,
17834, 17842, 17843, 17848, 17857, 17868, 17883, 17884, 17887, 17901, 17911, 17912, 17919, 17929,
18015, 18016, 18021, 18033, 18037, 18038, 18421, 18423, 18424, 18428, 18433, 18434, 18437, 18486,
18497, 18500, 18575, 19114, 19121, 19199, 19212, 19213, 19653, 18023

1. Impacts analyses are flawed.

Comment 1: Many commenters (16705, 17003, 17254, 17400, 17627, 17638, 17681, 17697, 17701,
17731, 17732, 17815, 17824, 17848, 17845, 17868, 17901, 17912, 17919, 18016, 18033, 18038, 18428,
18433, 18437, 18486, 18497, 18575, 19114, 19212, 19213, 18023) question the accuracy of the
economic and reliability analysis in the proposed rule because it does not take into account the other
major expenditures that will need to be undertaken by the utilities sector in the next 5 to 8 years to
comply with up to 8 other regulations. Commenters ask that the rules be considered together, or at least
that the Transport rule (CSAPR) be considered in conjunction with the proposed rule. Commenter 17701
encourages multi-pollutant solutions through a robust analysis of all the rules and guidance on cost-
effective multi-pollutant responses. Commenter 17815 asks that the EPA especially consider impacts on
regions such as Texas which rely more heavily on coal as a major fuel source, and commenter 17919
made a similar request in honor of the nation's "industrial heartland." Commenter 18428 believes the
EPA should evaluate the effects of regulations together, as industry does, to plan for compliance in the
most cost-effective manner possible. Commenter 18433 also explains that military buildup in Guam will
strain resources there, allowing insufficient capital to meet all these requirements. Commenter 18497
states that the industry decisions pertaining to adding needed generation capacity are being exacerbated
by the number of new or pending rules and requests a thorough analysis of the combined impacts.

Response to Comment 1: The final CSAPR was included in the baseline analysis for MATS and other
finalized air rules and regulations. As explained in the preamble to today's rule, the EPA considered
impacts on regional bases as part of its overall analyses, and these are discussed in the RIA and other
technical supporting materials.

The Agency did not prepare a cumulative impact analysis to accompany the rule for the following
reasons: 1) the various EO requirements that the Agency must comply with require us to estimate
impacts specific to this rule; 2) decision makers and the public need to know the impacts specific to a
particular rule in order to judge the merits of the regulation; 3) estimates specific to a particular rule are
more transparent than those from a cumulative impact analysis. A cumulative impact analysis lumps
several regulations together and can potentially mask a high-cost/low benefit regulation among other
rules that may have large net benefits. By analyzing each regulation separately, EPA makes clear
statements about what impacts, costs, and benefits will be generated as a result of this particular
regulation.

Comment 2: Several commenters (16705, 17884, 19741) state that the RIA is flawed and
underestimates the real impact. Commenter 16705 sees no regional additional impacts in several states
and references the White Paper, EPA's Utility MACTProposal: High Risk to the Economy and No
Incremental Benefit, March 15, 2011. Commenter 19741 states that contrary to the retirement
assumptions made for the agency's RIA, the NGS is scheduled to operate for a period of time beyond

490


-------
2015. The commenter is concerned that other faulty assumptions have been made in the RIA, including
negative economic impacts.

Response to Comment 2: The EPA recognizes its obligations under EO 13563 to use the best available
techniques to accurately quantify both present and future costs and benefits as well as to ensure the
objectivity of scientific and technological information and processes used in its analysis. As such, the
EPA relies upon guidance from its independent scientific and economic review panels and employs peer
reviewed processes and technical literature in completing its analyses. The methodology and
assumptions made for the analysis of the rule were included in the RIA that accompanied the proposal.

EPA modeling and projections are intended to be a reflection of possible compliance using specific
tools, assumptions, and methodologies that the agency believes to reflect the best and most current
information related to the power sector. It is not intended to reflect actual compliance decisions, since
those will be made individually be the affected industry based on what makes most sense using existing
technologies or other, more cost-effective strategies.

The EPA has conducted detailed impact analysis of the rule, which shows reasonable impacts to retail
electricity prices. The analysis provides a rich characterization of regional issues, and reflects the
differences in the power sector composition across those regions. The impact of the rule will vary across
regions, and the EPA has presented some of those impacts in the RIA. Overall, coal-fired generation is
not expected to change significantly since sources are anticipated to install pollution controls. In
addition, the EPA has conducted an updated employment analysis which shows some potential positive
and negative employment changes from the rule, but overall expects the employment impact to be
relatively small in comparison to the affected sector and the overall economy.

Comment 3: Commenter 17629 requests that the calculation and assumptions used to justify the
proposed rule be reviewed in detail.

Response to Comment 3: The EPA recognizes its obligations under EO 13563 to use the best available
techniques to accurately quantify both present and future costs and benefits as well as to ensure the
objectivity of scientific and technological information and processes used in its analysis. As such, the
EPA relies upon guidance from its independent scientific and economic review panels and employs peer
reviewed processes and technical literature in completing its analyses. The methodology and
assumptions made for the analysis of the rule were included in the RIA that accompanied the proposal.

EPA modeling and projections are intended to be a reflection of possible compliance using specific
tools, assumptions, and methodologies that the agency believes to reflect the best and most current
information related to the power sector. It is not intended to reflect actual compliance decisions, since
those will be made individually be the affected industry based on what makes most sense using existing
technologies or other, more cost-effective strategies.

The EPA has conducted detailed impact analysis of the rule, which shows reasonable impacts to retail
electricity prices. The analysis provides a rich characterization of regional issues, and reflects the
differences in the power sector composition across those regions. The impact of the rule will vary across
regions, and the EPA has presented some of those impacts in the RIA. Overall, coal-fired generation is
not expected to change significantly since sources are anticipated to install pollution controls. In
addition, the EPA has conducted an updated employment analysis which shows some potential positive
and negative employment changes from the rule, but overall expects the employment impact to be
relatively small in comparison to the affected sector and the overall economy.

491


-------
2.	General support for the proposed rule.

Comment 4: Commenter 16850 commends the EPA for allowing utilities to deploy various control
technologies in order to meet the proposed rule's air emissions standards.

Response to Comment 4: The EPA thanks the commenter for their observations.

3.	Flexibility in compliance.

Comment 5: Multiple commenters (16850, 16859, 17701, 17732, 17753, 17758, 17797, 17887, 17919,
18033, 18428, 19199, 19653) ask that the EPA avoid one-size-fits-all mandates and minimize costs by
allowing flexibility to choose compliance options that best fit the utility's system and customer base.
Some of these commenters cite EO 12866 and/or 13563 specifically in asking that the EPA allow more
flexibility and consider all rules associated with utilities together. Commenters 17701 and 18428 ask
that there be a continued dialogue with federal and state utility and environmental regulators to ensure
compliance does not hinder system reliability and minimizes cost impacts on consumers. Commenter
17701 includes the National Association of Regulatory Utility Commissioners resolutions as an
attachment. (Attachments - See DCN: EPA-HQ-OAR-2009-0234-17701-Al.pdf.)

Response to Comment 5: The EPA has attempted to provide the maximum flexibility to choose
compliance options that are permitted by the statute. The EPA does not endorse any specific pollution
control technology. The MACT standard is a technology-based standard that is established by
considering the maximum emission reductions currently achieved by the best performing EGUs in the
category. Individual facilities are free to use whatever technologies, processes, or other means they wish
in order to achieve this standard. The MACT standard encourages innovation by spurring companies to
develop more effective and efficient methods for achieving the necessary emission reductions.

The EPA has also attempted to provide flexibility for compliance by including, among other things,
variability in setting emission standards; provisions allowing emissions averaging among existing
sources in the same subcategory to demonstrate compliance; use of surrogates to determine compliance;
choice for existing sources to comply with input-based or output-based limits; and guidance on
appropriate use of the 1-year extension to comply with the proposed rule if additional time is needed for
installation of controls.

Comment 6: Commenter 17648 states that the EPA has appropriately incorporated provisions in the
proposed rule to provide regulated EGUs with flexibility to reduce emissions to achieve compliance in
the most cost-effective and efficient manner for that particular EGU. The commenter gives the examples
of these provisions as being:

1.	Work practice standards for dioxin/furans and non-dioxin/furan organic HAP

2.	EPA's treatment of variability in setting emission standards

3.	Provisions allowing emissions averaging to demonstrate compliance

4.	Use of surrogates to determine compliance,

5.	Choice for existing sources to comply with input-based or output-based limits

6.	Statutory eligibility for a one-year extension to comply with the proposed rule if additional time is
needed for installation of controls

7.	Provision of affirmative defense to any malfunction.

492


-------
The commenter calls on the EPA to resist calls to make the proposed rule less stringent on the grounds
that it will unnecessarily harm the industry.

Response to Comment 6: The EPA thanks the commenter for these observations.

4. Proposed rule does not properly account for all compliance costs.

Comment 7: Commenter 17758 discusses units that operate and dispatch primarily during times of peak
load/peak demand or in emergency situations, times of natural gas curtailment, etc. The commenter
explains that the levelized cost of generation for these units is higher than most other forms of electricity
generation and would increase with retrofitting with an ESP while offering very little environmental
benefit.

Response to Comment 7: The EPA does not believe there will be a significant impact on peaking units
as a result of the rule for several reasons. For example, the rule only effects oil/gas steam units and does
not cover gas combustion turbine or combined cycle units. Also, the EPA estimated that many oil/gas
units will convert, or have already converted, to natural gas. The rule contains "limited use" provisions
that will mitigate the impacts on many oil-fired facilities used for peaking and/or reliability purposes.
For those units that are expected to continue firing residual oil, many already have existing air pollution
control technologies (e.g., electrostatic precipitators) necessary to achieve the emission standards and
the remaining units that are not capable of converting to another fuel (e.g., subject to natural gas
curtailment) are expected to install cost-effective air pollution control technologies.

Comment 8: Commenter 17055 mentions that their initial assessment did not consider impacts the
RICE regulations may have on the potential loss of small units relied upon by many
municipalities. Elimination of these units could, the commenter believes, lead to local congestion and
require transmission expansion and local programs to meet demand. The commenter believes that
working with the industry to institute these changes will help preserve reliable system operations and
also allow for a more gradual integration of the costs of compliance that could significantly mitigate
reliability issues and sudden increases in consumer electricity prices. The commenter discusses an
evaluation of costs due to potential environmental control installations required for a specific group of
units if the owners determine that the units require retrofitted controls instead of closure. The estimate of
$8.5 billion would be required as initial investments for installation of the necessary controls, a number
that may make funding difficult and which will impact the consumer bills.

Response to Comment 8: The agency has analyzed resource adequacy issues and finds that there is
ample existing spare capacity to serve load after retirements are factored in, and industry has also shown
that it can build new capacity quickly in response to demand. The EPA believes it has appropriately
assessed the potential impacts of this rule, but also recognizes that individual plant retirement decisions
for compliance with the rule are made based on individual plant circumstances, and these decisions will
require evaluation of local market and transmission issues. The EPA will work with relevant authorities
to ensure a smooth transition with this rule. The final rule provides greater flexibility to deal with timing
when additional time is needed to address transmission issues arising from reliability issues related to
plant retirements. (See the preamble for the final rule.) In addition, there are certain provisions for
granting utilities some additional time to comply, if conditions warrant (see preamble).

Comment 9: Several commenters (17403, 18016, 18033, 18497) quote the National Economic Research
Associates analysis results showing the combined impacts of the proposed rule and the Clean Air
Transport Rule. The analysis shows the proposed rule is responsible for the majority of economic

493


-------
impacts that utilities will need to consider when planning for compliance. The commenters present an
estimation of compliance costs from this analysis of $17.8 billion in annualized compliance costs and a
total cost of $184 billion for 2011-2030, with estimated price increases from 12 to 23% in certain
regions.

Response to Comment 9: The EPA modeling of the final rule projects lower price impacts than noted
by commenter, and the analyses and results are fully documented in the supporting materials found in
the docket for today's rule (See RIA Chapter 3). The EPA has designed a rule that is intended to offer
flexibility, to the extent possible, while ensuring public health is protected in accordance with
requirements outlined in the CAA. The EPA has conducted detailed economic impacts analysis on the
regulated sector, and finds the impact of the rule on the regulated sector is small compared to the overall
benefits, and the industry has an excellent track record of installing pollution controls without greatly
impacting electricity prices. The report cited by the commenter is not transparent with regards to several
key criteria, making it impossible for the EPA to fully assess its value as a critique of the RIA.

Comment 10: Commenter 17638 states that the evidence shows that the EPA underestimated the impact
of compliance costs of the proposed rule including the following impacts:

1.	Electric grid reliability, including transmission

2.	The number of coal fired units retired in response to the proposed rule

3.	Increases in natural gas prices

4.	Increases in electricity rates

5.	The impact on national, regional and local economies.

The commenter requests that the EPA respond to the EI A, EEI, NERC, NERA, Credit Suisse, ICF, and
Burns & McDonnell and explain how its approach as directed by EO 13563 utilized the best available
techniques to quantify anticipated present and future benefits and costs..." The commenter further states
that the EPA does not consider the cumulative impacts of all its rules, as shown by wording on page
25058 of the proposed rule that it has yet to consider these cumulative impacts.

Response to Comment 10: The agency did not prepare a cumulative impact analysis to accompany the
rule for the following reasons: 1) the various EO requirements that the agency must comply with require
us to estimate impacts specific to this rule; 2) decision makers and the public need to know the impacts
specific to a particular rule in order to judge the merits of the regulation; 3) estimates specific to a
particular rule are more transparent than those from a cumulative impact analysis. A cumulative impact
analysis lumps several regulations together and can potentially mask a high-cost/low benefit regulation
among other rules that may have large net benefits. By analyzing each regulation separately, the EPA
makes clear statements about what impacts, costs, and benefits will be generated as a result of this
particular regulation.

This does not, however, mean the EPA has failed to consider cumulative impacts of the regulation. The
inclusion of CSAPR and other regulatory actions (including federal, state, and local actions) in the IPM
base case reflects the level of controls that are likely to be in place in response to other requirements
apart from MATS. This base case provides meaningful projections of how the power sector will respond
to the cumulative regulatory requirements for air emissions, while isolating the incremental impacts of
MATS. These results are presented in Chapter 3 of the RIA.

Additionally, the agency does reflect on the broader cumulative impacts of our regulations. In March
2011, the EPA issued the Second Clean Air Act Prospective Report which assessed at the benefits and

494


-------
costs of regulations pursuant to the 1990 Clean Air Act Amendments. The study examines the
cumulative impact of these regulations (found at

http://www.epa.gov/air/sect812/febl 1/summaryreport.pdf). As shown in the report, the direct benefits
from the 1990 Clean Air Act Amendments reach almost $2 trillion for the year 2020, a figure that
dwarfs the direct costs of implementation ($65 billion). The full report is at
http ://www. epa.gov/air/sect812/prospective2 .html.

The direct benefits of the 1990 CAA Amendments and associated programs significantly exceed their
direct costs, which means economic welfare and quality of life for Americans were improved by passage
of the 1990 Amendments. The wide margin by which benefits exceed costs combined with extensive
uncertainty analysis suggest it is very unlikely this result would be reversed using any reasonable
alternative assumptions or methods. This conclusion is likely to also be attributable to this rule as shown
in the RIA.

Comment 11: Commenter 17702 questions the solitary estimate for cost of compliance as opposed to
the range of monetized benefits for the proposed rule. The commenter believes that the EPA should
provide a range of costs based on best and worst case scenarios from the EPA's estimate of 11.1 GW of
coal-fired generation being shut-down, to other industry estimates of up to 48 GWs shutdown. The
commenter especially questions the EPA's assumption that new natural gas from shale formations will
provide sufficient gas to allow fuel switching from coal to gas, despite a recent New York Times article
indicating that the amount of gas may be overestimated. (New York Times article June 26, 20 II
"Insiders Sound an Alarm Amid a Natural Gas Rush")

Response to Comment 11: The EPA agrees that providing a range of estimates can be one way to
present the results of analyses, but it is certainly not the only way, and the EPA is not required by E.O.
13563 to present a range of impact estimates. The EPA has conducted sensitivity analyses that explore
key parameters in order to ensure its analyses are as accurate and reliable as reasonably possible, and the
corresponding impacts (including cost) can be found in Chapter 3 of the RIA for the rule. To the extent
that the background information on which news media relied for their reports is not in the record, we are
not able to comment on their veracity. The EPA recognizes its obligations under EO 13563 to use the
best available techniques to accurately quantify both present and future costs and benefits as well as to
ensure the objectivity of scientific and technological information and processes used in its analysis. As
such, the EPA relies upon guidance from its independent scientific and economic review panels and
employs peer reviewed processes and technical literature in completing its analyses. The methodology
and assumptions made for the analysis of the rule were included in the RIA that accompanied the
proposal.

Comment 12: Commenter 17718 states that the EPA's cost-benefit analysis underestimates compliance
costs for the commenter's subsidiaries in Kentucky. The commenter cites the costs of over $1.7 billion
in retrofits for the subsidiary to comply with the proposed rule, which is expected to translate into a
12.2% to 19.2% rate increase for customers in Kentucky by 2016, depending on their provider. The
commenter says that these rate increases do not include costs associated with retiring or replacing units
when they become uneconomical in 2016. The commenter states that costs of this magnitude for a utility
system with under 8,000 MW of coal-fired capacity shows that the overall compliance costs of less than
$11 billion are greatly underestimated. The commenter includes the following reference in a footnote:

In the Matter of: Application of Kentucky Utilities Company for Certificates of Public

Convenience and Necessity and Approval of Its 2011 Compliance Plan for Recovery by

Environmental Surcharge, KPSC Case No. 2011-00161, Application of Kentucky

495


-------
Utilities Company (filed June 1, 2011); In the Matter of: Application of Louisville Gas
and Electric Company for Certificates of Public Convenience and Necessity and
Approval of Its 2011 Compliance Plan

Response to Comment 12: The commenter has not provided the necessary information to enable the
EPA to evaluate commenter's assertions. The EPA has conducted a detailed national impact analysis of
the rule, which includes estimates of impacts to retail electricity prices that the EPA believes, in the
absence of contradictory evidence, is reasonable. Moreover, industry has shown in the past that it can
install significant pollution controls more cost-effectively than the EPA can sometimes anticipate.

Comment 13: Commenter 17743 states that the proposed rule's standards will apply to all power plants
in Oklahoma and is expected to involve widespread installation of new emission control technologies at
great compliance cost.

Response to Comment 13: The standards do not cover all power plants in Oklahoma. Rather, the
standards apply to coal- and oil-fired EGUs of greater than 25 MW. The EPA has conducted a detailed
national impact analysis of the rule, which includes estimates of impacts to retail electricity prices that
the EPA believes, in the absence of contradictory evidence, is reasonable. Moreover, industry has shown
in the past that it can install significant pollution controls more cost-effectively than the EPA can
sometimes anticipate.

Comment 14: Multiple commenters (17281, 17299, 17305, 17306, 17849, 19041, 19123, 19209)
express concern that proposed rule may affect the affordability and reliability of their electrical services,
and ask for more flexibility.

Commenter 17753 believes that the EPA's estimate of $10.9 billion in annual incremental compliance
costs in 2015 are underestimated by half. The commenter asks the EPA to carefully analyze the cost
estimates and impact on grid reliability and energy costs and revise the final rule appropriately, or
withdraw the rule entirely since it can't be justified technically or economically.

Response to Comment 14: The agency prepared a resource adequacy analysis for the proposed rule and
has revised that analysis for the final rule. The agency is also working with FERC regarding the
reliability impacts of this rule. The EPA has outlined the various flexibilities associated with the rule, to
the extent permitted by the CAA, and the approaches to reliability issues in the preamble. The
commenter has not provided evidence demonstrating that the cost estimates are underestimated. The
RIA for this rule estimates the annual compliance costs for this rule and the results of these analyses are
contained in the RIA documents, in various TSDs prepared for this rule, and the results are summarized
in the preamble for this rule. Results of these analyses are available in various level of detail in the RIA
and the TSDs, and the detailed results can be found in the docket for this rulemaking and through the
official web site for this rule.

Comment 15: Commenter 17761 believes the EPA compliance cost estimation is too low. The
commenter cites the $17,000 incremental cost for burner inspection and states that their experience with
such inspections gives a very different number.

Response to Comment 15: The EPA is sensitive to the concerns raised by the commenter about the
costs of a complete burner inspection requiring a unit outage and internal boiler scaffolding and so we
are adjusting the time period between burner inspections not to exceed 36 months. Additionally, a unit
that employs neural net combustion optimization software during all periods of normal operation may

496


-------
not exceed 48 months between burner inspections. This allows the burner inspection to be combined
with other critical work projects that require internal access to the unit, and reduces the overall cost
burden of the work.

Comment 16: Commenter 17765 reports the cost of complying with just the acid gas standard of the
proposed rule could easily be over three times higher than the EPA's projection and total almost $12
billion per year. This is already more than the EPA's estimate of $10.9 billion annually for compliance.
The commenter goes on to state that private sector estimates of unit retirement are much higher than the
EPA's estimate, ranging from 50 to as high as 100 GW in retirements, as opposed to the EPA's estimate
of 10GW.

Response to Comment 16: The EPA disagrees with commenter's assertion that the EPA's cost
projection is understated, and maintains that the EPA's incremental cost and retirement projections are
reasonable. The EPA also notes that the estimates commenter refers to do not necessarily project
impacts based on an identical policy. The EPA has conducted detailed impact analysis of the rule, which
shows reasonable cost impacts. Industry has shown that it can install large amounts of pollution controls
and often finds more cost-effective compliance options than the EPA can anticipate.

Comment 17: Commenter 17775 reports that a comparison of a Hg-only MACT rule to an all-HAP
MACT rule leads to an additional $30 billion in overnight capital expenditures for additional pollution
control equipment and an additional $13 billion in overnight capital expenditures for new capacity
additions. The commenter mentions that an all-HAP rule results in 5 GW of additional plant retirements
when compared to a Hg-only rule.

Response to Comment 17: The EPA disagrees with commenter's characterization of the additional
costs associated with today's rule as "overnight capital expenditures," as existing affected sources have
up to 3 years to comply with the rule (including the potential for an additional year for the installation of
controls), and capital costs are typically amortized over an extended period of time. Comparing the
estimated costs of complying with today's rule with those of a Hg-only rule is inappropriate, as the EPA
is establishing standards for all HAP emitted from EGUs consistent with CAA section 112. The
preamble provides further discussion of the legal requirements that the EPA has sought to comply with
in adopting today's rule. The EPA believes, in the absence of contradictory evidence, that the costs
imposed by the rule are reasonable. Moreover, industry has shown in the past that it can install
significant pollution controls more cost-effectively than the EPA can sometimes anticipate.

Comment 18: Commenter 17813 points out that fabric filters were not included in costs for beyond-the-
floor limits, but should be included since it is still unknown if ESPs can meet the PM standard.

Response to Comment 18: The EPA has conducted detailed impact analysis of the rule and includes
cost of fabric filters, ESPs, and ESP upgrades. The cost results can be found in the RIA of the rule, and
EPA has also included additional information documentation for the Integrated Planning Model.

Comment 19: Commenter 17824 questions the proposed limits on the disposal of coal residuals or ash,
which will cost up to $20 billion over the next 50 years.

Commenters 17868 and 17911 express concern that coal ash may be designated as hazardous waste
under RCRA (Subtitle C), causing state and municipal governments to feel compelled to remove and
remediate the coal ash fill from under buildings, at landfills, and under highways. These costs are not

497


-------
considered in the estimated cost for the proposed rule. The commenter estimates coal ash disposal costs
as hazardous waste to range from 5% to 24% of a municipal government's revenues.

Response to Comment 19: These comments are not within the scope of this rulemaking and, thus, the
EPA is not providing a response. The EPA is addressing issues related to coal combustion residuals in a
separate rulemaking.

Comment 20: Commenter 17824 discusses the proposed ozone limits being lowered from 0.075 ppm to
0.060-0.070 ppm. The commenter states that a limit of 0.060 ppm will change 13 of Alabama's 14
monitored counties to non-attainment status and move 85% of monitored counties nationwide to non-
attainment status, leading to a cost of $20-$90 billion annually and potentially costs up to 7 million jobs
by 2020 and close many of these counties to new business.

Response to Comment 20: This comment is not within the scope of this rulemaking and, thus, the EPA
is not providing a response. The EPA is addressing issues related to the NAAQS for Ozone in a separate
rulemaking.

Comment 21: Commenter 17824 discusses the regulation of three utilities operating 12 EGUs affected
by the proposed rule. Between them the utilities estimate compliance costs of $116.2 million in capital
costs, and an expectation that the proposed rule would contribute to the retirement of 2 of the units for a
loss of 253 MW. More of these units may be retired, depending on the final rules promulgated for the
interrelated regulations currently targeting utilities.

Response to Comment 21: The EPA has designed the rule to mitigate the impacts to the extent possible
and finds that a very small amount of the coal fleet could retire in response to the final rule requirements
(less than 2% of the coal fleet). Sources have a wide variety of compliance options by modifying
operation or installing pollution control technologies and it is unclear whether the commenters have
undertaken a rigorous effort to identify and evaluate such alternatives in the course of their analysis.

Comment 22: Commenter 17686 asks that the EPA acknowledge the price increase per MW for
compliance as the size of the unit decreases. Commenter 18021 agrees with this additional strain on
smaller units, due to the economy of scale. The commenter believes that the EPA did not consider the
disproportionately large cost of compliance for small communities, many of which are also suffering
economic hardship from falling tax revenue. The commenter cites the Bernstein and EPRI data analysis
which chose coal plant retrofits for SOx control technologies to cost approximately 3 times more per
MW for small units. (The commenter includes the following references : U.S. Utilities: Coal-Fired
Generation Is Squeezed in the Vice of EPA Regulation; Who Wins and Who Loses?, Bernstein
Research, 2010., "The Hidden State Financial Crisis," Wall Street Journal online publication, May 18,
2011.)

Response to Comment 22: The EPA's analysis includes scaling factors for pollution controls,
depending upon the size of a particular unit. See documentation for the IPM for more detail.

Comment 23: Commenter 17883 owns and operates several coal-fired facilities subject to the proposed
rule and sees the proposed Hg limits as difficult to achieve without costly modifications while other
facilities will require modifications to meet HC1 limits. The costs are estimated to be $60 million for one
facility.

498


-------
Response to Comment 23: The EPA recognizes that the final rule will obligate source owners to install
additional controls and has attempted both to minimize unnecessary additional costs and to accurately
estimate the costs to the industry. The EPA cannot verify commenter's assertions with regard to any
particular unit or facility.

Comment 24: Commenter 18425 expresses concern about the compliance costs of the acid gas controls,
which the commenter believes will have a large impact on Indiana coal industry. The commenter
considers the conclusion that regulating acid gases is necessary to be incorrect and creates costs greater
than what is necessary to protect public health.

Response to Comment 24: The EPA disagrees with the commenter for the reasons set forth in the
proposed rule and this final action. The commenter provides no information that causes the EPA to
reconsider our conclusions. The EPA has conducted detailed impact analysis of the rule, which shows
reasonable cost impacts. Industry has shown that it can install large amounts of pollution controls and
often finds more cost-effective compliance options than the EPA can anticipate. Comments concerning
the necessary finding and section 112(d)(4) standards are addressed elsewhere in the final rule record.

Comment 25: Commenter 19121 considers the EPA's estimated compliance costs to be underestimated
since forced retirements and fuel switching are not properly attributed.

Response to Comment 25: The EPA disagrees with commenter's assertion that compliance costs are
underestimated or that there is anything in the rule that requires a unit to retire, since retirements are the
products of economic business decisions left to the owner. Commenter does not provide detailed
information on the "forced retirements and fuel switching" that commenter alleges are not properly
attributed.

Comment 26: Commenter 18433 explains the costs for units in Guam and references cost estimates in
the Edison Electric Institute report on average retrofit capital cost for ESPs and DSI technology. The
commenter references a table created for the 4 units which will be subject to the proposed rule. [See
Table 2 in EPA-HQ-OAR-2009-0234-18433-A3]

Response to Comment 26: The EPA has included a separate category for non-continental liquid oil-
fired EGUs (see preamble).

5. Proposed rule does not properly account for all other impacts.

Comment 27: Commenter 17408 considers the proposed rule and other new or proposed rules focused
on the coal industry. The commenter points out that hundreds of thousands of people make a living from
coal and cites a Penn State study that showed there to be up to 11 jobs created for every one coal job.
The commenter also states that millions of people rely on the electricity that coal provides.

Response to Comment 27: The EPA has conducted detailed impact analysis of the rule, which shows
impacts that the EPA judges to be reasonable. The EPA has designed the rule to mitigate the impacts to
the extent possible and finds that a very small amount of the coal fleet could retire in response to the
final rule requirements (less than 2% of the coal fleet). In addition, there are certain provisions for
granting utilities some additional time to comply, if conditions warrant (see preamble). The EPA has
also conducted an updated employment analysis which shows some potential positive and negative
employment changes from the rule, but overall expects the employment impact to be relatively small in
comparison to the affected sector and the overall economy.

499


-------
Comment 28: Commenter 17707 discusses the Alabama Power installation of $2.6 billion worth of
emission control technologies, including SCRs and scrubbers with reduced emissions from their coal-
fired units approximately 65% since 1996. The commenter considers the EPA's new standards to be
unreasonable because any benefits would be incremental and outweighed by the costs of compliance.
The commenter states that small coal-fired units will not be able to afford upgrades and the proposed
rule will result in lost jobs and revenue due to high compliance costs.

Response to Comment 28: The benefits of this rule encompass the benefits of Hg reductions and co-
benefits to health achieved via PM2.5 reductions. The EPA has conducted detailed economic impacts
analysis on the regulated sector, and finds the impacts of the rule on the regulated sector are small
compared to the overall benefits, and the industry has an excellent track record of installing pollution
controls without greatly impacting electricity prices. In addition, the EPA has conducted an updated
employment analysis which shows some potential positive and negative employment changes from the
rule, but overall expects the employment impact to be relatively small in comparison to the affected
sector and the overall economy. The EPA has provided pursuant to CAA section 112(i)(3)(A) the
maximum 3-year period for sources to come into compliance. Sources may also seek a 1-year extension
of the compliance period if the source needs that time to install controls. The EPA will work with
relevant authorities to ensure a smooth transition with this rule and address specific issues. In addition,
there are certain provisions for granting utilities some additional time to comply, if conditions warrant
(see preamble).

Comment 29: Several commenters (17716, 17731, 17797, 17810, 18929) discuss the assertion that
energy efficiency policies reduce the total cost of implementing the proposed rule. Commenters 17716
and 17731 point out that the proposed rule has no effect on whether efficiency savings are realized and
these savings do not serve as offsets to the higher compliance costs imposed by the proposed rule.
Commenters believe energy efficiency had only a modest, indirect effect in later years and references
Table 23, lines 3 and 4 on page 25074 of the proposed rule, which shows incremental annual compliance
costs with and without energy efficiencies. The compliance cost is the same for both options in 2015,
and changes only from $9 billion (with) to $10 billion (without) in years 2020 and 2030. The
commenters also disagree with claims that energy efficiencies will offset rate hikes. The commenters
believe changes in the amount of energy used are more likely to be due to the economic necessity of
using less energy to save money following price increases, rather than due to energy efficiency
improvements.

Response to Comment 29: The EPA has designed a rule with considerable flexibility in accordance
with the requirements of CAA section 112. Within the limitations established by the rule, the final
choice of methods for reducing emissions remains at the discretion of the owner or operator. However,
the EPA believes energy efficiency measures can be a complement to this rule, and can be an important
tool in helping address emissions. The EPA has not included all the likely additional energy efficiency
measures that may occur by 2015, but will continue to pursue energy efficiency improvements
throughout the economy, along with other Federal agencies, states and other groups. This will contribute
to additional environmental and public health improvements while lowering the costs of realizing those
improvements.

Comment 30: Several commenters (17791, 18421, 18434) acknowledge that the proposed rule
recognizes the role of energy efficiency in reducing compliance costs and notes that the EPA cannot
mandate energy efficiency policies. The commenters quote the EPA estimate that energy efficiency
could reduce costs of the proposed rule by $2 billion in 2015, $6 billion in 2020 and $11 billion in 2030.
Commenter 18434 believes that since energy-efficiency investments are concentrated in densely

500


-------
populated areas with highest demand, even limited policies in the existing sensitivity analysis are likely
to have greater benefits than estimated. This commenter also states that both state and federal
policymakers are making progress in the area of energy efficiency, making the potential for fuel savings
through efficiency greater than that estimated. The commenter urges the EPA to modify the analysis to
reflect the State Energy Efficiency Action Network recommendations. The commenter understands that
the EPA cannot mandate efficiency programs, but it can urge state regulators to view compliance
extension requests more favorably from facilities making efforts to advance efficiency.

Response to Comment 30: The EPA agrees that energy efficiency measures can be a complement to
this rule and can be an important tool in helping address emissions. The EPA has not included all the
likely additional energy efficiency measures that may occur by 2015, but will continue to pursue energy
efficiency improvements throughout the economy, along with other federal agencies, states and other
groups. This will contribute to additional environmental and public health improvements while lowering
the costs of realizing those improvements.

The final rule provides 75% credit for thermal output in the definition of "gross output" (this is the value
that was proposed). This value has been increased in the NSPS from the original 50% credit a few years
ago to recognize the environmental benefit of CHP and has been carried over to the NESHAP.

Comment 31: Some commenters (17689, 17824, 17887, 17912, 18021, 18037, 18500, 19212, 18023)
express concern about the combination of multiple regulations currently proposed and the limited
timeframe for compliance with these proposed rules. Commenter 17689 mentions the NSR and
permitting requirements for the installation of control technology, and the fact that this process can take
over a year. This would be likely to create a backlog at state agencies, making it nearly impossible to
meet the compliance timeline. Commenters 17824 and 18023 in particular cite the EEI study that found
50% of the U.S. coal fleet may be unavailable by 2015 as a result. Commenter 17887 points out that
many generators will need the same equipment and specialized labor, leading to price pressure and
equipment shortages due to the tight timeline. Commenters 17912 and 17689 question the need for
outages to install equipment for multiple rules during the same timeframe, which will require more time
than is allowed under these rules. The commenter sees this as particularly problematic for IPPs, because
they typically do not have enough EGUs to avoid reliability issues with such outages and will have to
pay to replace the capacity. Commenter 18037 explains the difficulties for planning without time to
consider economies of scale, or co-benefits that could be realized by the installation of one type of
equipment as opposed to several. Also, this commenter discusses the physical space constraints for some
plants looking to retro-fit control equipment. To remain competitive, facilities must add control
equipment as it is needed, and adding equipment before it is necessary is financially imprudent.

Response to Comment 31: One of the purposes of developing the NSPS and MATS rules in tandem
was to facilitate more cost-effective compliance planning by affected source owners and, while the EPA
acknowledges concerns expressed by the commenters, it continues to believe that it has sought to
minimize any hardships associated with compliance. As part of the analysis supporting the rule, the EPA
has included a TSD on feasibility of installing pollution controls, and additional detail on timing can be
found in the preamble.

Comment 32: Commenter 18015 believes as an owner/operator of three large coal-fired power plants
that the proposed rule will have significant impacts on the company's operations.

Response to Comment 32: The EPA has conducted detailed impact analysis of the rule, which shows
impacts the EPA has judged to be reasonable. The EPA has designed the rule to mitigate the impacts to

501


-------
the extent possible. In addition, there are certain provisions for granting utilities some additional time to
comply, if conditions warrant (see preamble).

Comment 33: Commenter 18486 urges the EPA to discontinue the regulation of power plants until it
has studied the combined impact of current and pending rules on natural gas rules and how those
impacts affect agriculture.

Response to Comment 33: The EPA is subject to a Consent Decree in the matter of American Nurses
Ass 'n v. EPA, 08-2198 (D.D.C.). That decree requires the EPA to sign the final MATS rule by
December 16, 2011.

Comment 34: Commenter 18023 reports that the roughly 400 GW of capacity affected by the proposed
rule and other pending or new regulations are vital to adequate electricity supply and provide substantial
generator-supplied frequency control capability to the bulk power system. The commenter states that the
aggregate impact of these rules will require unprecedented levels of generation and transmission
construction in a short time period and could force industry to operate in uncertain conditions. System
changes in the electricity industry must be evaluated in advance so the system can be planned and
operated such that the causes and effects can be understood, and costs and problems minimized.

Response to Comment 34: The EPA analysis indicates that there will be a small amount of coal
retirements (less than 2% of all coal-fired capacity) and that coal-fired generation will not change
significantly. The agency has also assessed resource adequacy, and has determined that there is
sufficient excess capacity in existence that will help serve load. In addition, there are certain provisions
for granting utilities some additional time to comply, if conditions warrant (see preamble). The EPA will
work with relevant authorities to ensure a smooth transition with this rule and address specific issues.

6. Coordination of rules regulating similar pollutants.

Comment 35: Commenter 17627 states thatNSPS requirements in the proposed rule have the potential
to retire coal generation without an economical replacement, increasing costs to the public. The
commenter asks that the proposed rules that deal with the same pollutants be coordinated so that one is
implemented and given time to realize benefits before another program controlling the same pollutants
are implemented. The commenter believes this approach would produce the desired environmental and
human health benefits while maintaining system reliability and minimizing costs.

Response to Comment 35: To the extent possible, the EPA has coordinated the rulemakings. However,
CAA section 112 provides statutory compliance times which preclude doing much of what commenter
seeks. Other comments on the compliance time issue are responded to elsewhere in the final rule record.

Comment 36: Commenters 17681 and 17901 state that the EPA's initiatives will each have an impact
on electricity cost and transmission and together the compliance costs could disproportionately impact
the elderly, minorities and low-income citizens. The commenters consider the prominent rules at issue to
include:

(a)	2010 NAAQS for NO2;

(b)	2010 NAAQS for S02;

(c)	2011 NAAQS for ozone;

(d)	2011 NAAQS for PM2 5;

(e)	2011 Cross State Air Pollution Rule (CSAPR);

502


-------
(f)	2012 Revisions to the CSAPR;

(g)	2011 Industrial Boiler MACT;

(h)	Regional Haze Rule;

(i)	GHGPSD and Title V permitting;

(j) GHGNSPS;

(k) 2010 revisions to 40 CFR Part 63, subpart ZZZZ;

(1) 316(b) cooling water intake structures;

(m) Steam Electric Effluent Guidelines;

(n) Numeric nutrient criteria;

(o) Total Maximum Daily Load rules; and

(p) Coal Combustion Residuals.

The commenters also ask that the EPA honor EO 13563 by considering these rules together. Commenter
17901 estimates that the combined rules will directly impact approximately 400,000 MW or oil- and
coal-fired generation, or 40 to 50% of national electricity generation.

Response to Comment 36: The EPA acknowledges that elderly, minority and low-income populations
are overrepresented among those persons who live in close proximity to coal-fired power plants. For that
reason, the EPA expects that elderly, minority, and low-income population groups would benefit
disproportionately from the reduced emissions that will result from the rulemaking. The agency did not
prepare a cumulative impact analysis to accompany the rule for the following reasons: 1) the various EO
requirements that the agency must comply with require us to estimate impacts specific to this rule; 2)
decision makers and the public need to know the impacts specific to a particular rule in order to judge
the merits of the regulation; 3) estimates specific to a particular rule are more transparent than those
from a cumulative impact analysis. A cumulative impact analysis lumps several regulations together and
can potentially mask a high-cost/low benefit regulation among other rules that may have large net
benefits. By analyzing each regulation separately, the EPA makes clear statements about what impacts,
costs, and benefits will be generated as a result of this particular regulation.

This does not, however, mean EPA has failed to consider cumulative impacts of the regulation. The
inclusion of CSAPR and other regulatory actions (including federal, state, and local actions) in the IPM
base case reflects the level of controls that are likely to be in place in response to other requirements
apart from MATS. This base case provides meaningful projections of how the power sector will respond
to the cumulative regulatory requirements for air emissions, while isolating the incremental impacts of
MATS. These results are presented in Chapter 3 of the RIA.

Additionally, the Agency does reflect on the broader cumulative impacts of our regulations. In March
2011, EPA issued the Second Clean Air Act Prospective Report which assessed at the benefits and costs
of regulations pursuant to the 1990 Clean Air Act Amendments. The study examines the cumulative
impact of these regulations (found at http://www.epa.gov/air/sect812/febl 1/summaryreport.pdf). As
shown in the report, the direct benefits from the 1990 Clean Air Act Amendments reach almost $2
trillion for the year 2020, a figure that dwarfs the direct costs of implementation ($65 billion). The full
report is at http://www.epa.gov/air/sect812/prospective2.html.

The direct benefits of the 1990 Clean Air Act Amendments and associated programs significantly
exceed their direct costs, which means economic welfare and quality of life for Americans were
improved by passage of the 1990 Amendments. The wide margin by which benefits exceed costs
combined with extensive uncertainty analysis suggest it is very unlikely this result would be reversed

503


-------
using any reasonable alternative assumptions or methods. This conclusion is likely to also be attributable
to this rule as shown in the RIA.

Comment 37: Commenter 17751 quotes EO 13563 and EO 13576 about overlapping, redundant or
inconsistent requirements as well as doing everything in the Government's power to stop wasteful
practices. The commenter questions the EPA's choice to impose several regulations instead of one. The
commenter quotes the EPA study that states implementation of the 1997 NAAQS for ozone and PM
may lead to Hg reductions, but went on to say that the reductions could not be sufficiently quantified.
The commenter questions the validity of the statement and asks the EPA to develop and implement a
procedure to provide reasonable upper and lower bound estimates of PM reductions likely to be
achieved through state SIP programs. The commenter acknowledges that the estimates may not be
completely accurate, but believes providing an estimate would be more helpful than not including one.
The commenter believes that by not making a prediction, the EPA is essentially assuming the benefits of
the state SIP programs on Hg will be zero, which is not credible and leads to inflated benefit estimates of
the proposed rule.

Response to Comment 37: Where the opportunity is presented, the EPA seeks to coordinate efforts to
comply with multiple CAA requirements. In implementing rules such as the MATS, emission controls
may lead to reductions in ambient PM2.5 and ozone below the NAAQS for PM and ozone in some areas
and assist other areas with attaining these NAAQS. Although both RIAs calculate PM and ozone costs
and benefits, it is important to note that there are key differences in the design and analytical objectives
of a NAAQS RIA and one for a rule such as MATS. The NAAQS RIAs illustrate the potential costs and
benefits of attaining a new air quality standard nationwide based on an array of emission control
strategies for different sources. In short, NAAQS RIAs hypothesize, but do not predict, the control
strategies that states may choose to enact when implementing a NAAQS. The setting of a NAAQS does
not directly result in costs or benefits, and as such, the NAAQS RIAs are merely illustrative and are not
intended to be added to the costs and benefits of other regulations that result in specific costs of control
and emission reductions. Some costs and benefits estimated in this RIA account for the same air quality
improvements as estimated in the illustrative PM2.5 and ozone NAAQS RIA, but these effects are only
counted once when considering cumulative costs and benefits.

Comment 38: Commenter 18033 addresses the EPA's decision to wait until the NSPS for GHG
emissions rulemaking before considering coordinated control strategies for EGUs. The commenter
considers this approach to be too late, since many utilities much begin complying with CSAPR within
the next few months and will have only 3 years to comply with the proposed rule once it is finalized.
The commenter states that the EPA is obligated to help the regulated community plan for all interrelated
regulations and cumulatively assess the societal impacts of these regulations, which has not been done in
this instance. The commenter sees the combined regulations impacting American competitiveness as
increased prices undermine businesses ability to compete and sending businesses and jobs overseas.

Response to Comment 38: The EPA believes that by proceeding with the rules being adopted today,
which were developed with explicit consideration of the impacts of CSAPR, it is striking a reasonable
balance between seeking necessary protections of public health and coordinating efforts for the NSPS
and MATS to minimize unnecessary costs to industry. Rules under development for GHG emissions
will fully consider requirements adopted in today's regulations and seek to minimize or eliminate
disruptive impacts on compliance planning and implementation.

7. Impacts on tribal nations.

504


-------
Comment 39: Commenter 17732, as a tribal nation and small government landlord of affected EGUs,
states that the EPA is obligated to consult with the commenter and analyze the economic impacts to the
commenter in promulgating the proposed rule. The commenter further states that EPA is required to
tailor the proposed rule so that the costs of compliance for plants on the commenter are achievable
within a reasonable timeframe, while taking into account the unique challenges of the plants for this and
future rulemakings. The commenter explains that compliance costs to meet BART have the potential to
impact the commenter's economy significantly. The commenter is concerned that the proposed rule will
create a recurring threat of severe reductions in the revenue received from the power plants and their
supplying mines. The commenter explains that FCPP and NGS are subject to proposed BART
determinations and that EPA, Region IX, proposed an Alternative Emission Control Strategy ("AECS"),
a better-than-BART determination for FCPP. The AECS takes into account the FCPP proposal to
shutdown Units 1, 2 and 3. The loss of this total net capacity of 560 MW by 2014 would result in 100%
control of NOx, S02, PM, Hg and other hazardous pollutants from these EGUs, which would
significantly reduce emissions from FCPP. Currently, the EPA, Region IX, has delayed proposing
BART for NGS until at least December, 2011, pending consultations with stakeholder tribes. After
publication of the ANPRM for BART, the commenter recommended a phased approach to emissions
controls for FCPP and NGS, and suggested that the EPA consider the multiple interests at stake,
including the significant economic interests of the commenter. The commenter asks that the EPA
analyze the impacts from these rulemakings and provide flexibility for compliance scheduling so that
FCPP and NGS, upon which the commenter relies, can continue operations.

Response to Comment 39: Landlords of affected facilities are not included in the definition of an
affected small entity and, thus, were not included in the EPA's analysis of small entity impacts. The
EPA conducted multiple consultations with the tribes, including the Navajo Nation and has sought to be
responsive to concerns raised in those consultations. As to comments about an obligation to tailor the
rule to the Navajo Nation's economy, the CAA imposes certain specific requirements and the EPA does
not believe that it permits tailoring to the extent that appears to be requested by the commenters.

With respect to compliance, the EPA has provided pursuant to CAA section 112(i)(3)(A) the maximum
3-year period for sources to come into compliance. Sources may also seek a 1-year extension of the
compliance period from their title V permitting authority if the source needs that time to install controls.
CAA section 112(i)(3)(B).

8. Methodology and assumptions in calculations.

Comment 40: Commenter 17810 recognizes that the EPA can consider costs as part of the beyond-the-
floor analysis, but asks that the EPA clarify the methodology and assumptions used and expand the
analysis to include potential cost effectiveness of repowering coal-fired units as natural gas combined
cycle units. The commenter provides recommendations on the technologies used in combusting natural
gas, fuel costs and pipeline costs. (Insert included in original letter 17810-Al_Table2Pagel7.doc.) The
commenter questions the pipeline construction costs for converting existing coal units to natural gas
since they do not accurately reflect the costs a unit owner would face in repowering to natural gas. The
commenter cites an example case in Oklahoma for which the EPA's methods result in cost estimates 20
times greater than a more site-specific estimate. The commenter offers a table showing two example
coal-to-gas repowered units for which the EPA estimate is approximately $375 million while the total
costs using Navigant estimates are $52 million. The number of pipeline laterals seems to create the
largest estimate differences. The commenter notes that the EPA estimates seem to show laterals cannot
draw more than 10% of the mainline capacity, but the reason for this assumption is not shown.

505


-------
Commenter 17810 also requests clarification on the "Incremental Fixed Costs" equation and any
assumptions made about plant life. The commenter questions whether the manner in which the EPA
evaluated these costs is scientifically sound, since the report only includes costs associated with
retrofitting a 303 MW unit at static technology, pipeline and fuel costs. The commenter notes that no
information on why the EPA chose to estimate costs for only one unit or chose a 303 MW unit. Since
these costs can vary greatly depending on the unit size, the commenter suggests that the EPA conduct a
sensitivity analysis showing the costs of retrofit options for different size units and fuel price points.

Commenter 17810 suggests the EPA analyze the costs of retiring existing coal units and creating new
capacity on sites closer to pipelines. The commenter asks that the EPA include an evaluation of
repowering to natural gas combined cycle units in the evaluation of the cost of control options since
there are efficiency advantages over boiler-based technologies.

Response to Comment 40: The EPA disagrees with commenter's assertion that NGCC repowering and
coal-to-gas (CTG) switching at existing coal plants were not adequately evaluated. The EPA's IPM
modeling inherently considers new NGCC capacity as an alternative to continued operation of existing
coal units, with and without retrofit air emission controls. The EPA's IPM modeling for MATS also
offers a CTG option for existing coal units, wherein the CTG capital cost is properly scaled to the
existing unit size. The EPA's TSD discussion of CTG used an average unit size of about 300 MW only
to illustrate the approximate average economics of alternative (and collective) control options, including
CTG. The EPA has fully documented its peer-reviewed methodology and assumptions for assessing the
impacts of this rule, which can be found in the documentation for IPM

(http://www.epa.gOv/airi:narkets/progsregs/epa-i.pin/index.html). The documentation includes generation
technology assumptions, pollution control cost assumptions, fuel supply assumptions, and financial
assumptions governing the power sector.

9. Energy efficiency reduces compliance costs and emissions.

Comment 41: Commenter 17843 appreciates the Energy Efficiency Scenario that illustrates how the
costs of the proposed rule can be lowered through energy efficiency investments instead of retrofitting
pollution controls or building new generation units. The commenter points out that energy efficiency
also enhances reliability as it encourages retirement of the least efficient units as demand decreases. The
commenter points out that some states are pursuing aggressive programs and directing investments for
energy efficiency with proven results. The commenter cites the following article: Regional Greenhouse
Gas Initiative, Inc. (RGGI, Inc.). "Investment of Proceeds from RGGIC02 Allowances."RGGI, Inc.
(February 2011), at http://www.rggi.org/docs/Investment of RGGI Allowance Proceeds.pdf (accessed
July 8, 2011).

Response to Comment 41: The benefits of energy efficiency policies are discussed in the preamble.
These impacts include reduced need for construction of new generating capacity as well as reduced need
for construction of emissions controls such as FGDs. The EPA has designed a rule with considerable
flexibility in accordance with the requirements of CAA section 112. The EPA believes energy efficiency
measures can be a complement to this rule, and can be an important tool in helping address emissions.
The EPA has not included all the likely additional energy efficiency measures that are likely to occur by
2015, but will continue to pursue energy efficiency improvements throughout the economy, along with
other Federal agencies, states and other groups. This will contribute to additional environmental and
public health improvements while lowering the costs of realizing those improvements.

506


-------
Comment 42: Commenter 17929 states that new boilers can reduce emissions by incorporating energy-
efficient designs that allow them to use less coal to produce the same amount of electricity. The
commenter points out that a boiler operating at 40% efficiency will use 10% less coal to produce the
same amount of power than if it is operated at 36% efficiency.

Response to Comment 42: The EPA generally agrees and thanks the commenter for their observation.

Comment 43: Commenter 18421 discusses the role of energy efficiency in reducing costs and
preserving reliability. The commenter cites studies by McKinsey and Company, MIT's Innovations,
U.S. DOE and others that see benefits to more efficient processes and improved demand-side energy
efficiency programs. The commenter compares the Toxics Rule Case without energy efficiency to the
Toxics Rule Case with energy efficiency and found that the efficiency policies reduce the need for new
capacity by 0.3 GW in 2015, by 8.5 GW in 2020, and by 39.8 GW in 2030. The commenter also notes
that the reductions lower annual average electricity demand growth. The commenter cites a 2009 study
by the American Council for an Energy-Efficient Economy which found by looking at programs in 14
states that efficiency programs by the utility sector cost one-third less than investing in new generation
of any type. A report by Synapse Energy Economics reinforced the finding and showed that the highest
cost per kWh saved through energy efficiency was 3 cents, compared to the national average of 9 cents
per kWh of delivered electricity. (The commenter provided the following references as footnotes:
RIA8.13 Illustrative End-use Energy Efficiency Policy Sensitivity RIA8 Appendix D. For example,
McKinsey& Company, "Unlocking Energy Efficiency in the U.S. Economy," (July 2009), Hannah
ChoiGranade, Jon Creyts, Anton Derkach, Philip Farese, Scott Nyquist, and Ken Ostrowski
(http://www.mckinsev.com/clientservice/electricpowernaturalgas/downloads/us energy efficiency full
report.pdf) and Electric Power Research Institute, "Assessment of Achievable Potential of Energy
Efficiency and Demand Response Programs in the U.S. (2010-2030)," (January 2009),
(http://www.edisonfoundation.net/iee/reports/EPRI SummaryAssessmentAchievableEEPotential0109.p
df). American Council for an Energy-Efficient Economy, Saving Energy Cost-Effectively: A National
Review of the Cost of Energy Saved Through Utility-Sector Energy Efficiency Programs, September
2009. 105 States evaluated are: California, Connecticut, Iowa, Massachusetts, Minnesota, Nevada, New
Mexico, New Jersey, New York, Oregon, Rhode Island, Texas, Vermont, and Wisconsin Synapse
Energy Economics, Inc, No Need to Wait: Using Energy Efficiency and Offsets to Meet Early Electric
Sector Greenhouse Gas Targets, May 2009.)

Response to Comment 43: The studies cited provide information on the cost-effectiveness of energy
efficiency policies that are generally consistent with the sources cited for the EPA analysis.

10. Fuel switching.

Comment 44: Commenter 18423 questions the EPA's statements and calculations pertaining to fuel
switching as a regulatory option. The commenter questions the lack of consideration for new gas units to
replace coal units and the rejection of fuel switching as an option due to the lack of supply/availability of
natural gas and the cost. The commenter reviews the capital costs calculated by the EPA and concludes
that the ratio of cost of fuel switching from coal to gas is 18-53% higher than the alternative, rather than
4 to 22 times the cost of the alternatives. The commenter sees an error in the EPA's calculations because
it does not consider that fuel switching to natural gas removes the expense of coal for retrofitted units.
The commenter refers to the "Base and Incremental Fuel Costs" table created by the EPA in which it
appears the cost of coal at $22.4/MWh is not included in the control technology refit scenario
comparisons.

507


-------
Response to Comment 44: The EPA disagrees with commenter's assertion that EPA calculations
comparing the coal-to-gas (CTG) boiler conversion option to other retrofit control options incorrectly
included the base cost of coal fuel (as well as gas fuel) in the CTG incremental fuel cost. The EPA
incremental cost calculations are correct. Furthermore, EPA's IPM analysis has fully considered and
included the multitude of compliance options available to sources. The IPM analysis indicates that there
will be a small amount of coal retirements (less than 2% of all coal-fired capacity) and that coal-fired
generation will not change significantly. The agency has also assessed resource adequacy, and has
determined that there is sufficient excess capacity in existence that will help serve load. The EPA
modeling fully reflects the costs of competing fuels, and the results can be found in Chapter 3 of the
RIA. The EPA responds to comments associated with requiring units to switch to natural gas in response
to comments on the beyond the floor analysis elsewhere in the final rule record.

11. Miscellaneous.

Comment 45: Commenter 17752 expresses concern about the risk of noncompliance for early action.
The commenter explains that if controls are installed based on the proposed rule do not achieve the
reductions required by the final rule, the unit owner faces enforcement penalties because there is not
market in which to buy allowances to cover the compliance shortfall. The commenter also notes that
utilities contemplating retrofits to units in rate-regulated states run a risk of non-recovery if they make
capital commitments before the final rule is issued.

Response to Comment 45: The EPA is allowing a 3-year compliance timeframe for existing sources
affected by the rule, and there are also conditions under which extensions could be granted (see
preamble for additional discussion on timing.

Comment 46: Commenter 19114 questions the lack of documentation to support conclusions about the
amount to capacity that would or would not need to add fabric filters to meet the proposed PM limits.
The commenter requests full emission data and projections along with details on which technologies,
controls and units are likely to meet the HAP standards with or without the use of a fabric filter.

Response to Comment 46: See Documentation Supplement for EPA Base Case v.4.10_MATS -
Updates for Final Mercury and Air Toxics Standards (MATS) Rule for a detailed description of the
assumptions used by EPA regarding fabric filter retrofits in the modeling done in support of the final
rule.

Comment 47: Commenter 17701 points out that their organization members have a history of
supporting cost-effective energy efficiency measures and are leaders in reducing emissions, increasing
energy efficiency and promoting renewable and clean energy sources.

Response to Comment 47: The EPA thanks the commenter.

Comment 48: Commenter 18424 points out that the estimates of cost of compliance show much of the
cost is associated with acid gas controls, which the commenter believes will have a strong impact on
Indiana coal industry. The commenter considers the decision to regulate acid gas to be incorrect because
the costs are more than what is necessary to protect public health.

Response to Comment 48: The EPA's response to comments concerning the regulation of all HAP
emitted from EGUs is addressed elsewhere in the final rule record.

508


-------
6F - Control Technology Cost Assumptions

Commenters: 16469, 16705, 16826, 16849, 17296, 17386, 17400, 17408, 17620, 17621, 17622, 17623,
17627, 17648, 17655, 17682, 17702, 17721, 17731, 17734, 17736, 17754, 17756, 17757, 17758, 17761,
17765, 17770, 17775, 17790, 17796, 17807, 17810, 17821, 17840, 17842, 17868, 17869, 17881, 17885,
17904, 17911, 17912, 18017, 18033, 18037, 18421, 18433, 18437, 18447, 18484, 18500, 18575, 19114,
19122, 19213, 19536/19537/19538, 18023

1. Coal ash/coal combustion residuals.

Comment 1: Many commenters (16705, 17702, 17400, 17754, 17758, 17770, 17775, 17821, 17868,
17881, 18437, 18500, 18575, 19213) question the assumption that facilities will be able to sell or trade
coal ash/coal combustion residuals despite possible changes that could occur in the sodium content of
the ash due to new emission control technologies being required. Increased sodium could render the ash
unable to be sold and lead to coal ash management costs in addition to lost revenue. Commenter 18500
points out the EPA identified 93 GW of capacity that it expects to utilize ACI to meet the proposed
requirements. This commenter states that the beneficial reuse market for fly ash tops $2 billion annually,
so the use of ACI would risk eliminating the market and forcing landfilling of these residuals at a
dramatic increase of operating cost. The commenters believe these considerations should be included in
the costs.

Comment 2: Commenter 17754 states the limitations placed by the proposed rule on the sale of coal ash
potentially interferes with broader environmental considerations because they may impede the continued
beneficial use of coal ash for the reclamation of abandoned mining lands.

Comment 3: Multiple commenters (17621, 17758, 17754, 17775, 17821, 17868, 17881) discuss the use
of sodium-based DSI and the impact it could have on marketability and beneficial use of fly ash in
concrete, wallboard, asphalt products, bridge construction and mine reclamation. The commenters state
that around 134 million tons of coal combustion residuals are currently generated every year and 56
million of these are recycled in these applications. The loss of these uses, the commenters say, will cause
the coal ash/coal combustion residuals to be disposed of instead of used beneficially, causing economic,
operational and environmental burdens. Coal-based facilities will need to expand existing disposal units
or construct new ones, which can take several years and cost millions of dollars per unit not accounted
for in current cost estimates.

Comment 4: Some commenters (17758, 17775, 17821, 17868, 17911) explain that fly ash must meet
product specifications to be used in certain applications to assure high-quality products, such as an
appropriate alkali limit for use in concrete to avoid expansion and cracking. The commenters explain
that the sodium-based sorbent injection technologies cause fly ash to exceed the appropriate alkali
criteria, exceed necessary carbon content, and are soluble, making it unsuitable for use in ready-mix
concrete. The commenters go on to explain that solubility is also increased, making it unsuitable for
other established uses, such as mine reclamation. The commenters point out the previous testimony by
the EPA about beneficial uses of coal ash/coal combustion residuals saving virgin resources and
reducing energy consumption, reducing GHG emissions and the need for land disposal and ask that the
forfeiture of environmental benefits of coal ash/coal combustion residuals be assessed and considered in
overall policy evaluation. Comment 5: Commenter 17821 reports that 3 million tons of coal ash/coal
combustion residuals is beneficially reused by their organization annually, but this will end if they must
install sodium-based DSI or ACI. This will lead to loss of jobs and an economic impact on the utility
plant and end users of the coal ash/coal combustion residuals.

509


-------
Response to Comments 1-5: Multiple commenters declare that DSI and ACI controls contaminate
coal ash/coal combustion residuals, thereby rendering the co-mingled material unmarketable. The EPA
notes (from the comments submitted) markets purchased 56 million tons of the 134 million tons of coal
ash/coal combustion residuals - a fraction of the total coal ash/coal combustion residuals generated.
Removal of this entire quantity due to contamination from the marketplace can be adequately satisfied
by the remaining coal ash/coal combustion residuals produced. By the comments submitted, not all coal
ash/coal combustion residuals generated is sold; rather a sizable portion (58 percent) is disposed.
Moreover, the coal ash/coal combustion residuals marketplace sets specifications for allowable
contaminate levels; depending upon ACI and DSI flow rates, this may or may not render ash
unmarketable. The EPA concludes negligible impacts to downstream coal ash/coal combustion residuals
end-users market.

As for coal ash/coal combustion residuals producers, only 42 percent of ash sells to the market (56
million tons of 136 million tons) thereby making it a minor revenue stream for an EGU. As mentioned
before, depending upon ACI and DSI flow rates in conjunction with coal ash/coal combustion residuals
buyer's specification, the ash may retain marketability. As for contaminated ash, a station's owner may
install a secondary particulate capture device dedicated to removal of DSI absorbents or activated carbon
downstream of existing PM equipment. This second PM device preserves coal ash/coal combustion
residuals ash sales while reducing waste volume generated. Finally, for those EGU's electing to dispose
of the contaminated ash, the EPA models this cost at $50 per ton for disposal costs. The EPA believes
multiple options exist for EGU owners to implement the most economical compliance action for
adhering to MATS regulation.

Several commenters are concerned that sorbent injected by DSI and ACI controls will contaminate
CCR, particularly fly ash, to such an extent that the co-mingled material is unmarketable. The EPA has
modeled DSI and ACI in a manner that includes the cost of an additional secondary PM collection
device, a fabric filter (FF), dedicated to the collection of injected sorbent downstream of the existing PM
collection device. This modeling assumption incurs the additional cost of a FF on most DSI retrofits and
on many ACI retrofits, in order to allow uncontaminated fly ash captured in the existing PM collection
device to remain marketable. Given that DSI and ACI remain economic for many units even with this
conservative cost assumption, the EPA concludes that there will likely be minimal impacts to the
downstream CCR end-user market. Furthermore, although the EPA based the costs and performance
estimates of DSI on use of Trona, the use of other reagents can mitigate or even avoid this problem
altogether. Sodium bicarbonate has been shown to be more effective than Trona, which would reduce
the sodium content of ash considerably. Activated lime hydrate is another alternative to Trona that
would avoid the concern about sodium solubility altogether. The CCR marketplace sets specifications
for allowable contaminate levels and these specifications vary based upon the ultimate purpose of the fly
ash. Depending upon ACI and DSI flow rates, the fly ash may or may not be rendered unmarketable. In
some cases the fly ash will remain acceptable for the original purpose; in some cases it may no longer be
acceptable for the original purpose, but it will be suitable for other purposes. Regarding any lost revenue
due to contaminated ash issues, the EPA observes that almost all of an EGU's revenues are derived from
electricity sales, with ash sales representing a very minor income stream at risk to demand forces within
the downstream market. Avoided disposal costs are often more significant than any CCR revenues, and
if the fly ash can be repurposed for a less valuable purpose, the financial impact to the facility would still
be small. Finally, and in any case, the EPA's modeling indicates that the majority of DSI installations
will likely be on smaller units because many larger units are already scrubbed for SO2 control and have
no need for DSI. For further discussion on IPM modeling assumptions, see the IPM documentation.

Also see the preamble for the final rule for additional discussion of DSI.

510


-------
As for activated carbon contamination issues, proper location of the injection point will prevent
contaminating salable by-products; note an additional PM capture device may be required for collecting
Hg-laden activated carbon downstream. An SCR with WFGD configuration burning fuels with
sufficient halogen content will oxidize Hg in the SCR followed by capture in the downstream WFGD
thereby eliminating the need for ACI. The dissolved water-soluble Hg species is easily separated in the
gypsum dewatering/washing process

Comment 6: Commenters 17868 and 17911 express concern that coal ash may be designated as
hazardous waste under RCRA (Subtitle C), causing state and municipal governments to feel compelled
to remove and remediate the coal ash fill from under buildings, at landfill, and under highways. These
costs are not considered in the estimated cost for the proposed rule. The commenters estimate coal ash
disposal costs as hazardous waste to range from 5% to 24% of a municipal government's revenues.
Commenter 17408 expresses concern about increasingly toxic fly ash as a result of using carbon
injection to comply with the rule.

Response to Comment 6: Federal statute limits MATS to stationary source emissions (see the preamble
for the final rule for applicability). As for contaminated ash, a station's owner may install a secondary
particulate capture device dedicated to removal of DSI absorbents or activated carbon downstream of
existing PM equipment. Issues regarding CCR remediation from prior utilization or disposal are not
within the scope of the MATS rule.

2. Dry sorbent injection.

Comment 7: Multiple commenters (17623, 17765, 17770, 17775, 17781, 17840, 18033, 18023) explain
that the estimated compliance cost and retirement rate is likely to be low because the assumption that
DSI and a baghouse will enable a bituminous coal burning source to meet the HC1 limit which may not
be realistic. Wet scrubbers are likely to be necessary and will increase compliance costs and the number
of plants to retire since they cannot afford compliance. Some commenters (17765, 18033, 19114) state
that the EPA needs to examine what portion of the estimated 56 GW of the existing fleet expected to
install DSI instead of scrubbers may realistically do so to more accurately estimate costs because the
commenter believes that cost of complying with just the acid gas standard could easily be almost $12
billion annually. Commenter 17770 reports findings from a testing program that shows DSI is able to
control acid gas HAP only from units burning low rank western coals. The commenter asks the EPA to
reconsider its projections regarding DSI to control acid gases based on data available from DOE-NETL
and others. Commenter 17775 refers to modeling that shows the proposed rule will result in tens of
billions of additional dollars for compliance due to standards for non-Hg HAPS that will require more
control than can be achieved with DSI alone and no measurable health benefits. Commenter 19114
states that few coal-fired units use DSI for any purpose and none have been identified that employ DSI
for HC1 control. Given the lack of practical experience in the industry, the commenter believes the EPA
should revisit the application and performance attributes of the technology or risk understating the
potential costs and number of induced unit retirements.

Response to Comment 7: DSI is commercially proven for acid gas control as vouched by Babcock &
Wilcox Company, one of the largest suppliers of air emission control systems in the world. According to
B&W (http://www.babcock.com/library/pdf/ps-451 .pdf):

"Dry sorbent injection (DSI) for acid gas control is not a new technology. DSI systems have been in
service for more than 20 years as an effective tool to reduce acid gas levels. S02 and HC1 emissions
are typically controlled together. In some industrial applications, HC1 may need to be controlled

511


-------
separately. Current and impending legislation are the drivers in determining the required emissions
levels. DSI is a cost-effective solution to control these emissions."

As discussed in the preamble, the EPA has used very conservative assumptions in modeling the
projected use of DSI technology. See the preamble for the final rule for a more detailed discussion of
DSI.

Comment 8: Commenter 17758 agrees that DSI can be used for compliance at many units cost
effectively, but strongly disagrees with the assumption underlying the proposal that DSI and dry
scrubbers will be the compliance method for acid gas control at all units because DSI has not been
widely demonstrated in practice. The commenter notes that out of 131 units that define the HC1 floor,
only 15 units currently use DSI, and only five of those units use DSI without FGD.

Response to Comment 8: The EPA does not believe that DSI and dry scrubbers will be the only
compliance options for control of acid gases, and utilities will choose compliance pathways based on a
variety of considerations and available technologies. DSI is a commercially available technology and the
EPA believes it will play an important role for achieving compliance. See preamble for further
discussion on DSI and other compliance options.

Comment 9: Commenter 16469 explains that DSI is applicable to smaller units burning low-sulfur
subbituminous coal. The commenter states that operational performance systems using sodium
bicarbonate indicate SO2 removal rates in the range of 20-60%, which is below the >90% SO2 removal
typically associated with wet scrubbers. The commenter includes a table showing removal rates for HC1
and SO2 at increasing bicarbonate flow rates in the range of 75-95% for HC1 and 20-60% for SO2. The
commenter reports that analysts believe that DSI is likely to be used by smaller units, with larger unit
installing scrubbers. The commenter also believes that additional controls may be needed to address
future regulations which could entail retrofit scrubbers and SCRs to achieve SO2 and NOx control.
Commenter 19114, on the other hand, states that they have installed over 10,000 MW of coal-fired units
and has experience with the operation of DSI and sees the quantities of Trona required for the needed
removal efficiencies to be too expensive and logistically cumbersome to maintain for smaller units.

Response to Comment 9: See the preamble for the final rule for a discussion of DSI.

Comment 10: Commenters 17620 and 17648 report that the ACI and DSI technology required to
comply with the proposed rule have existed for many years. Commenter 17620 states that these
technologies require little capital for construction and normally involve installation schedules of less
than 12 and 24 months, respectively while FGD and SCR technologies require longer schedules. The
commenter states that industry has demonstrated its ability to add the controls by the deadline, pointing
out that applicable compliance was achieved following past regulations being passed. The commenter
mentions the 26 GW of new SCR controls that came on line in 2003 to meet the NOx SIP, while
approximately 70 GW of SCR and 10 GW of FGD capacity were installed in 2000-2004. The
commenter cites IPM modeling estimates that show 83 GW of new scrubbing and 65 GW of DSI added
to the existing 145 GW of capacity that has scrubbing. Also, the estimates add 98 GW of ACI and 26
GW of new SCR for NOx control. Commenter 17648 confirms that ACI is a feasible control technology
for Hg emissions, regardless of the control technologies presently used to control for PM, SO2 or NOx
and gives examples of how this can be done. The commenter also points out that regulation often drives
development of cheaper, more efficient controls. The commenter confirms that technologies exist to
achieve the reductions called for by the proposed rule. The commenter believes that sources can

512


-------
reasonably expect to be able to alter source fuels or select and install suitable controls to achieve the
proposed emissions limits.

Response to Comment 10: The EPA thanks the commenter for the information provided in support of
the proposed rule.

Comment 11: Commenter 17648 disagrees with criticism that the EPA's analysis underestimates the
number of units that will need to install wet or dry FGD controls to meet the proposed acid gas limits.
The commenter says that DSI is a mature technology that is well suited for units that burn fuels with
lower or mid-level sulfur contents and is among the viable options for a number of sources to achieve
the proposed HC1 limits. The commenter points out that 73% of the sources with HC1 emission data in
the ICR database already achieve the proposed HC1 limit and several of them do so using DSI. The
commenter goes on to list coal-fired units that control SO2 using DSI.

Response to Comment 11: The EPA thanks the commenter for the information provided in support of
the proposed rule.

Comment 12: Commenter 17702 acknowledges that they have compliance options to meet the proposed
requirements, such as adding carbon injection or switching to a wet scrubber. However, the commenter
feels this will add additional costs and defeat the environmental objectives that led to the selection of
their air pollution control system, such as conserving water with a dry scrubber as opposed to a wet
scrubber and finding a way to use the calcium byproducts. However, the proposed emission limits will
require ACI, which will interfere with the ability to sell the byproduct.

Response to Comment 12: Although wet scrubbers (WFGD) use considerable amounts of water,
approximately 90 weight percent of the water can be recovered in a gypsum slurry dewatering process
and returned to the system. Water used for quenching incoming flue gas to the wet scrubber, can be
minimized by lowering flue gas temperatures to the minimum permitted by design.

As noted above, for activated carbon contamination issues, proper location of the injection point will
prevent contaminating salable by-products; note an additional PM capture device may be required for
collecting Hg-laden activated carbon downstream. An SCR with WFGD configuration burning fuels
with sufficient halogen content will oxidize Hg in the SCR followed by capture in the downstream
WFGD thereby eliminating the need for ACI. The dissolved water-soluble Hg species is easily separated
in the gypsum dewatering/washing process.

Current scrubbing technology captures MATS acid gases with superior effectiveness relative to SO2;20
as a result, the EPA does not anticipate scrubber retrofits for MATS compliance on units equipped with
a wet or dry scrubber.21 The EPA expects that a dry scrubber with a fabric filter is a control
configuration where no additional controls may be required in some cases.22 Where additional controls
are needed, the EPA believes that units with dry scrubbers with fabric filters may choose ACI, but they
may also find other approaches effective. In many cases, especially bituminous coal units, high co-

20	NESCAUM report; "Control Technologies to Reduce Conventional and Hazardous Air Pollutants
from Coal-Fired Power plants" March 31, 2011, pp. 11-12, 21

21	Assessment of Technology Options Available to Achieve Reductions of Hazardous Air Pollutants,
URS Corporation, April 5, 2011; p.7, Table 2-1

22	NESCAUM report; "Control Technologies to Reduce Conventional and Hazardous Air Pollutants
from Coal-Fired Power plants" March 31, 2011, p. 20

513


-------
benefit capture occurs without the need for ACI. For low rank coals, capture can be enhanced with
bromide addition. Experience has shown that addition of oxidizing agents (i.e., bromide) and/or the use
of sorbents designed to mitigate or avoid the adverse effects of activated carbon on fly ash, including
mineral-based sorbents, are available and effective.23 As a result, the EPA believes that facilities with
dry scrubbers are especially well suited to comply with the rule at relatively low expense.

Comment 13: Commenters 17736 and 19114 question the effectiveness of DSI to control acid gas
emissions from coal-based EGUs and point out that no such units have been identified as employing DSI
for HC1 control. The commenters have experience installing Trona injection systems on coal-fired units
and understand the shortcomings of DSI injection. As such, the commenters find SO2 removal by DSI to
be too costly and cumbersome to be practically applied. Specifically, the commenters find the nozzle
pluggage and antagonistic effects on ESPs would make achieving HC1 and PM limits difficult over a 30-
day period. Commenter 19114 questions the EPA's "Documentation Supplement for EPA Base Case
v4. lO PTox - Updates for Proposed Toxics Rule" which quotes a DSI test done by a company
specializing in this technology using Trona and other sodium-based sorbents to remove SOx and other
acid gases and will substantially benefit from regulation requiring DSI technology. The commenter
points out that the document referenced by the EPA is a simple slide presentation about a single test, and
lacks technical specifics that allow the data to be extrapolated to such a broad range of units as those in
the utility industry. The commenter expresses concern that the EPA allows for the use of DSI in
conjunction with existing ESP systems without regard to size or performance, as this is not supported by
available data. The commenter also questions the assumed SO2 removal of 50-70% with DSI, as it is not
supported by the indicated data. The commenter also worries that there could be potential cost premiums
for affected units if they are all forced to rely on a single vendor for the required technology and points
out that the testing reports used by the EPA do not evaluate potential operations concerns. The
commenter also states that the costs associated with maintaining a DSI system due to pluggage and
antagonistic effects on ESPs would make achieving both the HC1 and PM limits very difficult to achieve
over a 30-day operating period. The commenter calls on the EPA to expand the quantity and quality of
their review.

Response to Comment 13: The EPA has determined that DSI is an effective acid gas control
technology since MATS acid gas removal exceeds S02 capture rates with this technology.24 Despite
comments claiming DSI as too costly or cumbersome, this control technology occupies less space and
requires substantially less capital investment than a unit employing a wet or dry scrubber.25 However, a
DSI system's operating costs tend to exceed a wet or dry scrubber for high sulfur fuels. As a result, the
EPA's IPM modeling limited the DSI retrofit option to units combusting fuel less than 2.0 lb
S02/MMBtu. Pluggage issues result from poorly designed systems for powdered solids conveyance. A
variety of causes can lead to blockage; for example, poorly designed piping systems, inappropriate
storage practices, incorrect system operation, plus others. Similar problems arose and were solved in
analogous industries of food processing (wheat flour, powdered sugar), concrete (dry Portland cement),
and pharmaceuticals etc. regarding dry powder material transfer. The EPA has noted that there are
commercially available solutions to address these issues.26 Pluggage problems at a particular facility do

23	Hizny, W., Magno, G., Yang, X., "BASF Mercury Sorbent ZX™ for Control of Coal-fired Power
Plant Hg Emissions," Paper # 176, Power Plant Air Pollutant Control "MEGA" Symposium, August 30
- September 2, 2010, Baltimore, MD

24	NESCAUM report; "Control Technologies to Reduce Conventional and Hazardous Air Pollutants
from Coal-Fired Power plants" March 31, 2011, p. 22

25	ibid, p. 13

26	UCC web site; DSI FAQ #3 Plugging Issues. Web site: http://unitedconvevor.com/dsi.aspx

514


-------
not disqualify DSI as a commercially available control technology. With regard to impact on ESP
performance, DSI using sodium-based reagents has been shown to improve ESP performance; this has
been a consistent phenomenon that is the result of the beneficial impact of sodium sorbent on fly ash
resistivity. Also see the preamble for the final rule for a further discussion of DSI.

Comment 14: Commenters 17758 and 18033 discusses the EPA's acknowledgement that if DSI does
not achieve the required HC1 reductions, utilities will need dry or wet scrubbers to achieve compliance,
which the commenters believe will prompt more unit retirements. Commenter 17758 also mentions that
the cost for DSI varies from $4/MWh to $15/MWh and there are few suppliers of DSI technology,
especially the Trona. Commenters 17758 and 17775 cite difficulties with the Trona supply with
estimates of costs to deliver Trona to the eastern U.S. as high as $200/ton due to logistical difficulties.
For instance, the special rail cars needed, the limited plant storage silo sizes and short shelf-life of the
product al contribute to making increased Trona supply difficult to achieve. Finally, the commenters
note that units using DSI or ACI often need PM control downstream, such as a baghouse or ESP and a
baghouse typically takes 36 months to install and costs $200/KW. Overall, the commenters question the
cost-effectiveness of DSI, quoting BPC as saying that, ".. .capital costs for an alternative, dry sorbent
injection are significantly lower. On a levelized cost basis, however, the difference is far less
significant..Commenter 17781 agrees with this conclusion and says that while DSI can be economic
with low sulfur fuels and/or operated over short time periods, many EGUs will need to install spray
dryer adsorbers (SDAs) in lieu of using DSI, which means longer lead times for procurement and
installation of at least a year.

Response to Comment 14: The EPA disagrees with the commenters and does not expect that scrubbers
are necessary solely for acid gas control under the MATS rule. The EPA has analyzed the supply of
Trona and sodium bicarbonate and determined that it is ample, as soda ash (a product of mined Trona) is
already used extensively for other industries (such as glass manufacturing, detergents, etc.) that need a
reliable supply. Trona is a very reactive substance, and relatively small amounts are required to control
HC1. Trona DSI has also been shown to improve ESP performance, so that a fabric filter is generally not
necessary unless otherwise needed for PM control. As discussed in the preamble, recent testing shows
that trona DSI control of HC1 with an ESP is very nearly as effective as with a FF. Facility owners may
choose to install scrubbers for control of acid gas; however, this does not change the EPA's
determination that other technologies are available and can be used to comply with the rule at reasonable
cost and in the time frame of the rule. Also see the preamble for the final rule for a further discussion of
DSI.

Comment 15: Commenters 17765 and 18033 report that private sector estimates of retirements are
higher than the EPA's estimates because of the unproven effectiveness of DSI, the lack of reliability of
the reagent supply chain, the lack of industry experience with the technology and the potential impact of
dispatch. These concerns lead to retirement estimates of 50 to 100 GW. Commenter 17765 believes that
without further testing to show that DSI technology can be relied on for compliance, few utilities will
choose it. The commenter finds the EPA's compliance timeline makes it difficult for utilities to obtain
information necessary to make decisions about control technologies or unit retirement. The commenter
also points out that many of the 56 GW capacity units the EPA estimated would choose DSI will not
have that option due to overlapping CAA rules.

Response to Comment 15: The EPA disagrees with the commenters' assumptions. There have been
numerous private sector studies that examine retirements due to several EPA rules that have been
proposed or finalized over the past 2 years. Many of these studies were based upon assumptions of what
a rule might require prior to its proposal or finalization, and the assumed requirements were generally

515


-------
more stringent than the actual requirements proved to be. Although the EPA's modeling for MATS
predicts that some units will choose DSI, the EPA recognizes that some of these units may not actually
do so, for a variety of reasons that may involve owner preferences and site specific circumstances. Also
see the preamble for the final rule for a further discussion of DSI.

Comment 16: Commenters 17775 and 18037 discuss various adverse consequences of DSI use,
pointing out that it can hinder compliance with Hg and PM limits as the injected reagent adversely
affects baghouses, and requires that three times the normal amount of ACI be used to achieve the same
level of Hg control, as well as leading to the mission of a visible brown plume from the high sodium
content.

Response to Comment 16: The EPA is aware that there is some data suggesting DSI can adversely
impact ACI performance. In particular, the Presque Isle tests where this was observed were for S02
control, and the Trona treatment rate for those tests was therefore higher than would be necessary for
control of HC1 for PRB fuel. PRB fuel typically has low HC1 emissions and likely will not need
additional controls for HC1 in most cases. On the other hand, DSI can improve ACI performance for
bituminous units because of the reduction in S03, which interferes with ACI capture of Hg. DSI using
sodium compounds (Trona, etc.) has actually been shown to improve ESP performance. Therefore, little
or no adverse impact is expected with regard to PM. Improper DSI operation can adversely affects PM
and Hg control. Insufficient bag house capacity or excessive sorbent injection rate can adversely affect
PM control performance.27 An improper operating temperature reduces activated carbon's ability to
capture Hg28 while high concentrations of SO3 compete with mercury for capture.29 DSI systems failing
to remove sufficient S03 negatively impact ACI system performance.30 Hg speciation exiting the
furnace significantly impacts controls selection and performance, with multiple factors affecting
speciation (e.g., fuel constituents, halogen presence, installed emissions controls, and temperature).31'32
ESP performance typically improves with sodium based sorbents; on the other hand, a calcium based
species tends to negatively impact operation.33 The brown plume phenomenon apparently can occur
under conditions of high treatment rates on units that do not have NOx controls,34 but this is not
anticipated for HC1 control due to the lower treatment rate needed for HC1 removal. Formation of a
brown plume appears to be an event too infrequent to disqualify DSI as a control scheme within the
MATS. Represented by the Presque Isle tests, one system produced a brown plume; on the other hand,

27	Assessment of Technology Options Available to Achieve Reductions of Hazardous Air Pollutants,
URS Corporation, April 5, 2011; p.A-10

28	Ibid., p.A-8

29	Ibid.

30	Ibid.

31	Solvay Chemicals publication "Mercury (Hg)"

32	Tutorial: Mercury Chemistry in Boilers and Mercury Control Technology (Part 1) by C Senior,
Reaction Engineering Intl., 30th International Technical Conference on Coal Utilization & Fuel Systems;
April 17-21, 2005

33	UCC web site; DSI FAQ #1 ESP Performance. Web site: http://unitedconvevor.com/dsi.aspx

34	Sjostrom, S.,Senior, C., Durham, M., Bustard, J., "INTEGRATED MACT COMPLIANCE
PLANNING," http://www.adaes.com/PDFs/presentations/AQVIII-
Integrated%20MACT%20planning.pdf

516


-------
over 30 other DSI systems did not generate a brown plume.35 Also see the preamble for the final rule for
a further discussion of DSI.

Comment 17: Commenter 17775 explains that the assumption that an adequate supply of dry sorbents
will be available is not a good one. The commenter explains that sorbent production will need to
increase by 10 to 20 times in order to meet the EPA's projected DSI demand. This is a problem, the
commenter explains, because the industry is not going to spend hundreds of millions of dollars on plant
expansions without a secure market, but until the utilities decide to install DSI, they will not know what
the demand will be. Once a commitment is made, it will take more than 18 months to increase sorbent
production to necessary levels to supply all the projected new DSI units.

Response to Comment 17: Multiple comments submitted claim insufficient absorbent (or sorbent)
production capability exists to serve the DSI market. The agency researched this issue and determined
that DSI utilizes the following absorbent materials for pollution control: Trona, sodium bicarbonate,
sodium carbonate (common name: soda ash), calcium carbonate, and calcium bicarbonate - sodium
based chemicals are favored over calcium based materials due to economics. Trona is mined in
Wyoming as a naturally occurring ore by four companies with mining operations extracting 16.5 million
tons in 2010.36 Production peaked at 18.1 million tons in 2006.37 In 2010, end consumers received
176,000 tons of Trona via direct shipment38 while the balance was converted into soda ash and related
chemicals. Note that soda ash is an acceptable absorbent for DSI pollution control. Exports claimed one-
half of the 10 million tons of soda ash produced in 2010.39 Currently, the industry (ANSAC) alleges
unfair foreign practices negatively impacting domestic exports.40 Considering the excess Trona mining
capacity, the fact that nearly 50 percent of Trona-based derived soda ash is exported, and the fact that
alleged foreign competition practices negatively impact exports - the agency concludes that Trona
supply is not an issue.

The EPA disagrees with commenter's estimate and has concluded that current U.S. Trona production
may already have adequate surplus capacity to meet projected DSI demand. See the preamble for the
final rule for a further discussion of DSI.

Comment 18: Commenter 17790 explains that the EPA's analysis of emission reduction technologies
required by their facilities to comply with the proposed rule is erroneous because it assumes they will
install fabric filters on all coal-fired units. However, the commenter's analysis showed that DSI is only
economical on units which are able to achieve compliance-level reductions of HC1 using ESPs, and
spending additional money on fabric filters is not economical for them.

Response to Comment 18: The EPA's IPM modeling for the MATS final rule now takes into
consideration that there are less costly options than FF for PM compliance, particularly the upgrading of

35	"Comparison of Sodium Bicarbonate and Trona for S02 Mitigation at a Coal-Fired Plant" by Kong &
Vysoky (Solvay Chemicals) Electric Power 2009 presentation, May 12-14, 2009.

ref: http://www.solvair.us/static/wma/pdf/l/5/8/4/0/SQ2 Mitigation-Electric Power 2009.pdf

36	http://www.wma-minelife.com/trona/TronaPage2/trona_production.htm

37	ibid

38

http://www.onrr.gov/ONRRWebStats/StateAndOffshoreRegions.aspx?state=WY&veartvpe=FY&vear=
2010&dateType=AY

39	http://minerals.er.usgs.gov/minerals/pubs/commoditv/soda ash/mcs-2011 -sodaa.pdf

40	http://www.ansac.com/news/2011/06/01/

517


-------
existing ESPs. Please see the documentation for IPMv4.10MATS. In addition, Trona DSI has been
shown to improve ESP performance, a benefit that the EPA's IPM analysis has conservatively has not
incorporated. For these reasons, many units that were previously modeled as installing a FF may find
that only the installation of DSI upstream of the existing ESP may be needed for MATS compliance.
Also see the preamble for the final rule for a further discussion of DSI.

Comment 19: Commenter 18033 requests that the EPA address integrated planning after the proposed
NSPS for GHS from EGUs are issued to create a cumulative cost analysis. The commenter states that
neither a utility or public utility commission would permit the investment in DSI technology and sorbent
storage facilities if a scrubber would be needed a few years later. The commenter went on to explain that
not every coal type within the projected 56 GW expected to install DSI will be able to meet the
compliance limits using that technology. The commenter refers to Sargent & Lundy report which states,
"[t]he DSI technology should not be applied to fuels with a sulfur content of greater than 2 lb
S02/MMBtu." (Footnote 57 to EPA-HQ-OAR-2009-0234-18033-A2 gives NMA revised cost estimates
for DSI.)

Response to Comment 19: Issues regarding a NSPS for GHG from EGUs are not within the scope of
the MATS rule, although the EPA does intend to seek to coordinate requirements under today's rules
with those of the pending NSPS for GHG emissions. Also see the preamble for the final rule for a
further discussion of DSI.

Comment 20: Commenter 18421 states that DSI can be used with a variety of sorbents to allow an
approach tailored to the source and unit characteristics. The commenter quotes NESCAUM "Control
Technologies to Reduce Conventional and Hazardous Air Pollutants from Coal-Fired Power Plants,"
March 31, 2011, as estimating capital costs and storage silo costs for DSI at around $20/kW. The report
also cites approximately 90 coal units currently using DSI, showing that it is effective at reduction HC1
by more than 99% and works efficiently with a downstream fabric filter or ESP. The commenter also
quotes SOLV Air, a Trona distributor, as refuting claims that Trona is likely to be unavailable by saying
"hundreds of years of reserves of Trona are available." Commenter 17621 agrees with the idea of
various options for sorbents used with DSI technology and explains the various pros and cons of some
options. The commenter reports on a Trona injection test that resulted in a visible brown plume and
degradation of Hg removal by ACI. The commenter explains that while hydrated lime injection would
remove SO3 without the adverse impacts of Trona, it is unknown if the hydrated lime could meet the
proposed limit at any injection rate or if it would increase pressure drop across a baghouse to
unacceptable levels. The commenter also mentions the practice of grinding sodium sorbent before
introducing it to the feed system, then injecting the finer material upstream of the air preheater. This
practice is believed to increase mixing and residence-time, providing greater SOx and HC1 reduction.
However, the method can also lead to air preheater pluggage in some cases. The commenter describes a
field test program in which Trona or sodium bicarbonate was used to achieve high HC1 and SO2 removal
rates without pluggage problems. The commenter explains that the site has an atypical system including
both hot- and cold-side ESP, and sorbent was injected upstream of the hot-side ESP which may have
minimized pluggage and plumes. This commenter believes that further investigations are needed of DSI
over a range of power plant designs, coal types and air pollution controls to fully evaluate HC1 and SO2
removal performance and impacts on balance-of-plant operations.

Response to Comment 20: The EPA thanks the commenter for the information provided in support of
the proposed rule.

518


-------
Comment 21: Commenter 18424 considers the EPA estimates for control technologies to be suspect
since they may not be appropriate for use by many power plants, depending on the coal burned and the
impacts DSI will have on PM and Hg emissions. The commenter questions the method of developing
emission rules for each pollutant independently without considering how one control device may impact
the control of other pollutants.

Response to Comment 21: The EPA disagrees with commenter. The EPA evaluated the effects of DSI
on different fuels and considered the effects on Hg and PM emissions. See the documentation for
IPMv4.10_MATS, and the preamble for the final rule for a discussion of DSI. It is important to note that
the EPA established emission standards based on the best-performing sources in each subcategory for
the different emitted HAP. The EPA is not specifying the use of a particular control device, leaving it to
the discretion of the source owner or operator to select controls that will meet the applicable standards
considering the characteristics of the particular source.

Comment 22: Commenter 18023 disagrees with the assumption that 56 GW of coal plants will not need
a FGD system because DSI will suffice at a lower cost and shorter timeline for installation. The
commenter states that even if DSI can achieve the HC1 removal levels required to comply, it would not
do so under all operating conditions. The commenter states that the EPA's model predicted that several
of the commenter's power plants would not achieve continuous compliance with the proposed acid gas
limit using DSI. (Commenter includes Figure 6 showing necessary technology to achieve compliance
with proposed HC1 limit.) Therefore, the commenter believes the costs and timeline on which the
proposed rule is based are erroneously low. The commenter also disagrees with the assumption that wet
scrubbers will not be widely required to meet the proposed emission limits since dry scrubbers are more
appropriate for smaller units with lower sulfur fuels, which does not describe all units. The use of wet
scrubbers will also drive up compliance costs so the commenter asks that the EPA update cost
assumptions to account for these requirements.

Response to Comment 22: The EPA disagrees with the commenter. The EPA has determined that wet
scrubbers, while beneficial for acid gas control, are not necessary for compliance with the MATS rule.
Also see the preamble for the final rule for a further discussion of DSI.

Comment 23: Commenter 17775 states that the proposed rule will require large-scale installation of
new control technologies to meet the Hg, HC1 and total PM limits. The commenter restates the EPA
estimates that the proposed standards will require the installation of 93 GW of ACI, 56 GW of DSI, 26
GW of wet FGDs and dry FGDs, 166 GW of FF and 5 GW of SCR, and that this $46 billion (in 2007
dollars) of control equipment can be installed in 3 years. The commenter considers the EPA's estimate
to be unreasonable because it is based on incorrect assumptions about the efficacy of DSI.

Response to Comment 23: See the preamble for the final rule for a discussion of the efficacy of DSI.
Also see the RIA for projected controls retrofits and costs as updated in EPAs analysis for the MATS
final rule.

Comment 24: Commenter 17775 questions the EPA's conclusions about the effectiveness of DSI since
they are based on limited information and incomplete analyses. The commenter points to ICR data from
plants using DSI systems to see that only 11 of the 28 units using DSI do so to control SO2 and only two
of those 11 units report ICR emissions data that show compliance with the proposed existing source HC1
limit. In fact, those two cases the units burn low chloride fuel and do not need to install DSI to meet the
HC1 limit. Therefore, the commenter states that there is no example of an EGU system that complies
with the HC1 limit as a result of having a DSI system. The commenter also explains that the Sargent &

519


-------
Lundy report cited by the EPA to support its views on DSI are lacking information on how DSI may
affect PM or Hg emissions. Also, the commenter says that the Solvay Chemicals case study to predict
Trona feed rates for HC1 and SO2 removal was for sodium bicarbonate injection, not Trona, making the
feed rates inaccurate. In addition, the commenter points out that the flue gas make-up in the case study
was not representative of low sulfur coals.

Response to Comment 24: The EPA disagrees with commenter's conclusions. Also see the preamble
for the final rule for a further discussion of DSI.

Comment 25: Commenter 18963 notes that there have been no commercially demonstrated applications
of DSI for the control of HC1 from coal refuse-fired CFB units. Further, even to the extent that it is
technologically feasible to use sorbent injection to control HC1 from coal refuse-fired CFB units, the use
of different sorbents for this purpose may affect the quality of the ash residue. Such ash is currently used
in the environmentally-beneficial step of reclaiming lands and protecting and enhancing streams
damaged by acid mine drainage.

Response to Comment 25: See the preamble for the final rule for a further discussion of DSI.

Comment 26: Commenter 16849 states that even under revised averaging periods, Trona and DSI are
not a viable option for Empire, as is incorrectly stated by the EPA ("IPM Parsed Results - Policy Case,"
Unplanned DSI Installations by 2015 includes Asbury: 2076 B1).

Response to Comment 26: The EPA believes that DSI has the potential to be a useful and cost-
effective control technology option for many units. We also understand that it is not an appropriate
option for all facilities. Overall the EPA believes that the technology is most applicable for units burning
lower-sulfur content coal (including, potentially, low-sulfur bituminous coal).

3. Electrostatic precipitators.

Comment 27: Commenter 17622 explains that ESPs are the primary particulate collection equipment
for many utility units and are designed to have sufficient Specific Collecting Area (SCA) to meet the
proposed total PM emission limits. The commenter considers it to be in the best interest of the industry
to retain existing plant assets as much as possible while complying with the proposed rules. The
commenter explains that ESPs can be upgraded by improved maintenance/repair, parts replacement, etc.,
or rebuilding to increase SCA. However, the commenter points out that the potential for upgrading
existing ESP installations to meet the proposed limits depends on the age and design of the existing
equipment. Not all equipment was designed to achieve 0.03 lb/MMBtu to begin with, and may not be
able to comply with the proposed emission limits even after being rebuilt. Some equipment may require
expanded collecting area, but not have the space to accomplish this. Another solution, where space is
available is to add a polishing fabric filter after the ESP. Also, an existing ESP may be converted to a
pulse jet fabric filter. The addition of a fabric filter or conversion from an ESP to a fabric filter would
allow better utilization of Trona or lime for HC1 and SO3 control and allow the potential to include other
reagents for Hg control. There is an impact on the ID fans and structure to convert to a fabric filter, but
much of the existing support structure and ducts/casings could be used. The final solution suggested by
the commenter is the addition of a wet ESP to an existing wet FGD to capture filterable and condensable
particulate. The commenter offers the Dallman and HL Spurlock plants in the ICR PM database as
examples of this approach and explains that this alternative has the advantage of using existing air
pollution control equipment with low increase in pressure drop.

520


-------
Response to Comment 27: The EPA thanks the submitter for the information provided in support of the
proposed standard MATS and notes that this information corroborates the EPA's views about the
availability of multiple compliance options for many affected sources.

4. Timeline.

Comment 28: Several commenters (17627, 17655, 17911, 19114) express concern over the compliance
timeline of the proposed rule. In particular, the number of regulations focusing on the same pollutants in
the same timeline is a concern because of the pressure likely to be placed on control equipment suppliers
and skilled labor for installation will not allow all the units to acquire the needed equipment in the given
time period. Commenter 17655 reports that an SCR originally estimated to cost $33 million actually cost
them $61 million entirely due to the fact that all the CAIR-affected units were competing for the same
design, material and labor pools during a compressed construction schedule to comply. The commenter
expects the same thing to happen to a greater extent in response to the proposed rule.

Response to Comment 28: Commenters recalling price escalation during CAIR's implementation
phase understandably convey concerns regarding the EPA's cost estimating; however, the present
economic situation does not reflect current national or global conditions. During CAIR implementation,
high global demand for construction commodities (especially from China) attributed to cost escalation.
Presently, commodity prices are relaxed from their peak due to lower global economic activity.
Considering the current economy, the EPA anticipates the first wave of retrofit controls orders to be less
costly than recent historical prices since suppliers will compete for work to utilize idle resources. As an
indicator, demand for power plant construction labor declined from its peak in 2008.41 For example,
Colorado Springs Utility plans to retrofit its 254 MW Martin Drake unit with a FGD for $113 million
with projected construction completed by 2014.42'43 Timeline compliance date attainment and available
resources are addressed in the preamble for the final rule and Response to Comments section 5C01
"Compliance Dates."

Comment 29: Commenter 17627 explains that facilities must start now to assemble justification of
supplier and construction constraints to receive an extension from state regulatory agencies. However,
the commenter points out that this step is unreasonable before the final requirements are known and
compliance plans are designed, and permitting authorities generally do not allow any construction
preparation until permits are granted.

Response to Comment 29: The agency believes that the MATS proposal offered sufficient regulatory
detail to inform prudent retrofit planning activities, some of which at least could be commenced without
further delay. To cite an example, a station owner ordered two wet scrubbers (465 MW and 515 MW

41	Staudt, J., E., Andover Technology Partners, "Labor Availability for the Installation of Air Pollution
Control Systems at Coal-Fired Power Plants," www. AndoverTechnology.com, viewed November 6,
2011

42	http://www.power-eng.eom/articles/2011/10/coal-fired-power-plant-to-receive-emissions-control-
system.html

43	Colorado Springs Independent; Oct 4, 2011 "Update: Utility Strikes Deal on Emissions Control" by
Pam Zubeck

Ref: http://www.csindv.com/IndvBlog/archives/2011/10/04/utilities-strikes-deal-on-emissions-control

521


-------
units) with scheduled start dates of 2013 and 2015.44 Timeline compliance and resource availability are
discussed in the preamble for the final rule and Response to Comments section 5C01 "Compliance
Dates."

Comment 30: Commenter 17758 states that compliance for many utilities, especially those burning
eastern bituminous coals, may have to install a wet FGD which presents challenges in cost and
installation time. The commenter estimates wet FGD will cost approximately $350/KW more than DSI,
and the timeline for wet FGD installation will be around 60 months as opposed to 9-18 for DSI. This
makes the EPA's assumptions about both the cost estimates and ability to comply within 3 years
incorrect, the commenter believes.

Response to Comment 30: The EPA disagrees with comments warning wet scrubbers are necessary for
units burning eastern bituminous coal. The EPA examined this issue and determined DSI adequately
suffices for units burning low sulfur eastern bituminous coal. The EPA's IPM analysis for MATS limits
DSI retrofit controls for compliance to fuels containing less than 2 lbm S02/MMBtu. Timeline,
feasibility, and emissions control capability issues are discussed in the preamble for the final rule, and
Response to Comments section 5C01 "Compliance Dates."

Comment 31: Commenters 17775 and 17904 discuss the many steps involved in adding controls to
coal-fired EGUs, such as initial design, development of project specifications, procurement,
identification of bidders, solicitation, review of bids and contract negotiations, permitting, landfill
issues, obtaining financing, final design, mobilization of workforce, construction, process tie-ins and
startup testing. Commenter 17775 includes a memo (J. Edward Cichanowicz, "Feasibility of Retrofitting
Fabric Filter Particulate Matter Control Technology to the Electric Generating Unit Inventory as
Projected by EPA" (July 2011) Attachement 12 of EPA-HQ-OAR-2009-0234-17775) showing estimates
of 48 months to install a single scrubber for a large unit, 50 months for a single scrubber at a small unit,
51 months for installation of two scrubbers and 54 months to install three or more scrubbers at a single
facility. The memo also estimates that not all existing EGUs that need a new fabric filter will be able to
meet a 3-year compliance schedule, and even if given 4 years to comply, only 54% would be able to
comply. The commenter also explains that time needed to obtain financing can vary greatly, with some
regulated utilities needing to obtain approvals from their State PUCs to recover the costs, and some rural
cooperatives needing to access the private market for funding. Commenter 17904 refers to Davis Cnty.
Solid Waste Mgmt. v. EPA, 101 F.3d 1395, 1400 (D.C. Cir. 1996) wording that states the EPA's MACT
floor would "impose significant retrofitting costs that [are] unreasonable given the limited additional
pollution control that stricter standards would achieve." The commenter expresses concern over the high
costs and short timeline for the necessary control retrofits.

Response to Comment 31: For discussion on the issues mentioned above, see the preamble for the final
rule and Response to Comments section 5C01 "Compliance Dates."

Comment 32: Commenter 18039 questions the suggestion that existing units be allowed to run for an
additional year while a replacement is constructed, without being subject to MACT standards for that
year. The commenter agrees that this is a reasonable scenario for facilities that will use that year to
construct a replacement unit with significant long-term emission reductions. However, the commenter is

44 B&W press release June 29, 2011; "B&W to Design and Supply $54 Million Emissions Control
System for Indiana Power Plant" ref: web site:
http://www.babcock.com/news and events/2011/20110629a.html

522


-------
concerned that a facility in the process of building replacement power may decide to operate a high-
emitting unit for an additional year, specifically due to the extension. The commenter therefore objects
to the extension for fear a large amount of pollutants will result. The commenter also asks that if
construction replacement power lasts longer than the 1-year extension, the final rule wording make clear
that the older unit is not permitted to avoid MACT compliance beyond that year, even if the replacement
is not yet on-line.

Response to Comment 32: Issues regarding compliance dates, extensions, state programs regarding
agreements, replacement power construction, etc., are discussed in the preamble for the final rule.

Comment 33: Commenter 18017 states that if the proposed rule and other pending rules require
installation of new control equipment costing hundreds of millions of dollars, the potential result could
be early closure of their plant because the owners will be required to comply before they know whether
the approvals necessary to operate after 2019 can be obtained. The commenters concern is that the EPA
may establish final emission limits governing NGS PM emissions that are so stringent that a new PM
control device will be required with compliance dates before approvals can realistically be obtained.

This would lead to high compliance costs and could jeopardize continued operation of the NGS facility
with severe economic impacts on numerous Indian Tribes.

Response to Comment 33: The EPA will work closely with other regulatory authorities to support
timely implementation of MATS.

5. One technology per pollutant.

Comment 34: Commenter 17682 considers the EPA estimate of compliance technologies to be suspect
because of the proposal of adopting an untested compliance technology to reduce sulfur emissions, and
which may impact PM and Hg emissions. The commenter asks that the EPA refrain from developing
emission rules for each pollutant independently without considering how one compliance measure may
impact the control of other units. The commenter believes this approach leads to cost estimates that do
not adequately reflect the cost for other sources of energy that may be required to make up for lost coal-
fired generation. The commenter would like to see cost estimates that adequately reflect the ultimate
cost increases that individual home owners will need to pay.

Response to Comment 34: The agency reviewed all technologies presented within the proposal for
adequacy and commercial availability; moreover, independent publications and trade organizations
confirms their capability towards achieving MATS compliance.45'46'47

See the preamble to the proposed rule for a discussion of the pollutant-by-pollutant (or HAP-by-HAP)
approach for establishing section 112(d) standards.

Average projected cost increases to the rate payer are addressed in the preamble for the final rule.

45	NESCAUM report; "Control Technologies to Reduce Conventional and Hazardous Air Pollutants
from Coal-Fired Power plants" March 31, 2011

46	Assessment of Technology Options Available to Achieve Reductions of Hazardous Air Pollutants,
URS Corporation, April 5, 2011, http://www.supportcleanair.com/resources/studies/file/4-8-ll-
URSTechnologyReport.pdf

47	EPA-HQ-OAR-2009-0234-17622

523


-------
6.	Dual liquid-powder sorbent technology.

Comment 35: Commenter 17721 discusses a multi-emission reduction technology called involving a
dual liquid-powder sorbent (DLPS), which is particularly effective in removing Hg and other HAP by up
to 98.7%, along with SO2 and NOx emissions from coal-fired EGUs without adding control equipment
into the flue gas stream. The commenter suggests that the effectiveness of the DLPS system for high-
sulfur coals makes it a valuable revision to the proposed rule as an available technology for achieving
the emissions limits. The commenter also explains that limiting EGU MACT technology to ACI will
limit innovation of new technologies and flexibility within the industry and asks that the proposed rule
allow for a variety of Hg control systems.

Comment 36: Commenter 17721 considers the proposed rule vague on the point of demonstrating
compliance with the Hg emissions limit using a Hg CEMS or a sorbent trap monitor without installing
ACI or DSI. The commenter suggests revising the final rule to recognize DLPS technology as an
available emission control technology for Hg and other HAP, or at least make it clear in the preamble
that the use of a DLPS system instead of, or in combination with other technology, is permitted. The
commenter describes three power companies operating eight generating stations that have DLPS
technology installed, with results of up to 98.7% Hg reductions. The commenter points out that while it
is not yet used as extensively, the DLPS technology is superior to ACI in that it has been shown to
improve boiler efficiency in certain conditions, and fly ash from coal treated with DLPS has improved
characteristics for reuse, unlike ACI. The commenter describes testing done between 2005 and 2008 and
provides the results. (The commenter includes a table of "Full Scale Multi-Pollutant Test Results" in
EPA-HQ-OAR-2009-0234-17721 -A1.)

Comment 37: Commenter 17721 questions the proposed rule's focus on ACI technology, which works
differently from DLPS technology because ACI and DSI involve injecting a sorbent into the flue gas
stream upstream of a PM control device to react with acid gases and Hg in the exhaust stream. DLPS
technology, the commenter explains, captures Hg, HAP metals, SO2 and NOx during combustion to
keep them out of the exhaust stream. The commenter points out that DLPS technology offers effective
Hg and other HAP metals control for high-sulfur coals without the assistance of additional SO2
mitigation, making it a reasonable or superior choice compared to the DSI suggested in the proposed
rule. The commenter asks that the proposed rule be amended to allow DLPS technology as an available
control technology for Hg, HC1 and other HAP metals, and allow units equipped with DLPS or DSI to
qualify for SO2 emissions limits as an alternative to the HC1 emissions limit.

Comment 38: Commenter 17721 points out that the proposed rule focuses on controlling acid gas
emissions in the exhaust stack, while DLPS allows acid gas control in the furnace. The commenter states
that DLPS can achieve a 75% reduction in SO2 emissions before the exhaust reaches the stack, where
further emissions reductions could be achieved by a scrubber.

Response to Comments 35-38: Multiple comments were received advocating control technologies
that were not represented in the EPA's compliance cost analysis of the MATS proposal. The agency
notes that control technologies mentioned within the proposal are neither an exhaustive nor an exclusive
list; rather, these listings demonstrate proven available technologies for industry sector compliance. The
EPA is not selecting, nor precluding, any particular technologies in this rulemaking but is instead
allowing each facility to determine its preferred means of compliance with the emission rate standards.

7.	Retirements.

524


-------
Comment 39: Commenter 17731 questions the EPA's view that utilities can easily retire and replace
units that are unable to comply with the new emission limits. The commenter considers the option of
replacing older units with more efficient units to be risky because the utility may spend the time and
money to build new coal-fired units only to find out that the units cannot comply with the stringent new
unit emission limits.

Response to Comment 39: This issue is discussed in the preamble for the final rule.

8. Activated carbon injection and alternatives.

Comment 40: Commenter 17734 discusses the use of amended silicates as an environmental and
economical way to comply with existing and pending Hg regulations. The commenter describes
amended silicates as a "drop-in" alternative that is often superior to partially activated carbon, at a cost
competitive with ACI. The commenter explains that the amended silicates are added to the coal
combustion gases upstream of PM control equipment to modify Hg into an inert and insoluble state. The
commenter states that amended silicates have been designed to be compatible with concrete, allowing
for preservation of fly ash value, and passes the EPA leachability tests. The materials have also been
developed to avoid the sensitivity to SO3, so a high rate of Hg capture is maintained in ESPs. The
commenter requests that the EPA revise the proposed rule to clearly state that newly developed and
commercially-available products besides powder activated carbon can achieve similar or better results
under different or similar chemical mechanisms.

Response to Comment 40: Multiple comments were received advocating control technologies that were
not represented in the EPA's compliance cost analysis of the MATS proposal. The agency notes that
control technologies mentioned within the proposal are neither an exhaustive nor an exclusive list,
rather, these listings demonstrate proven available technologies for industry sector compliance. The EPA
is not selecting, or precluding, any particular technologies in this rulemaking but is instead allowing
each facility to determine its preferred means of compliance with the emission rate standards.

Comment 41: Commenter 17761 reports a dramatic decrease in performance of an ACI system between
the years of 2007 and 2009. Given this unexplained decline, the commenter feels it is necessary for the
EPA to review the longer term operating performance of control equipment when setting a Hg standard.

Response to Comment 41: Like any air pollution control technology, numerous parameters impact ACI
performance with possible causes due to operational changes, equipment degradation, etc. The owner
retains responsibility to maintaining their emissions control system and understanding its operation to
continuously achieve compliance. ACI is a proven technology for Hg removal with multiple successful
installations.48 This issue is addressed more fully elsewhere in the final rule record.

Comment 42: Commenters 17796 and 17869 indicate that the pollution control technology industry
continues to develop new and more cost effective ways to reduce Hg emissions. Commenter 17796
discusses the DOE research on costs of applying activated carbon at various sites. The commenter states
that this and other studies show a continued decrease in Hg control costs, with a decrease approaching
50% less for coal-fired EGUs than 1999 baseline estimates. Commenter 17869 quotes the OMB review
of ACI technology which states; "the availability and development of ACI technology has shown that

48 NESCAUM report; "Control Technologies to Reduce Conventional and Hazardous Air Pollutants
from Coal-Fired Power plants" March 31, 2011

525


-------
implementation can be done by a majority of utilities, and the competitive marketplace will continue to
reduce the costs for these technologies."

Response to Comment 42: The EPA thanks the commenters for the comments supporting the standard.

Comment 43: Commenters 17813 and 17816 state that the EPA fails to provide complete cost-benefit
analysis of beyond-the-floor limit. Commenter 17813 considers this to be an underestimate, in part
because more units will be impacted than predicted. The commenter sees the benefit for lignite beyond-
the-floor limits to be smaller than the annual benefits predicted for Hg reductions, since there are fewer
lignite units and they already comply with the floor limit.

Comment 44: Commenter 17930 states that the EPA failed to provide the proper cost-benefit analysis
given the disproportionally high cost of the beyond-the-floor limit compared to any potential gains.
According to the commenter, the EPA's estimate of annual cost of implementing the beyond-the-floor
limit ($86.7 million) is far greater than the possible benefits of the beyond-the-floor limit. The EPA
predicts that the annual benefit of Hg reductions for the entire rule is merely $450,000 to $890,000 by
2016. (See Utility MACT Rule Proposal at 25078. Price estimate at a 7% discount rate. At a 3%
discount, the estimated Hg-related benefits are $4.1 to $5.9 million.) The commenter adds that the
benefit for the lignite beyond-the-floor limit must be much smaller given the proportion of lignite units
compared to other coal- and oil-fired units and since lignite units would already be complying with a
floor limit.

Comment 45: Commenter 17904 questions the EPA assumption that a unit equipped with ACI and a
fabric filter can achieve the beyond-the-floor standard with no additional cost. The commenter explains
that such systems have performance limitations and will not achieve the proposed limit consistently, so
alternative and additional controls will need to be considered. The commenter agrees with the dismissal
of fuel switching because the variable Hg content of lignite combined with captive mine mouth designs
makes the economic impact a marker for establishing actual costs of compliance, which would be
prohibitive.

Response to Comments 43 - 45: A quantitative analysis of costs was included in two beyond-the-floor
TSDs to illustrate the feasibility of the beyond-the-floor standard for lignite. The EPA established the
BTF limit since ample evidence for ACI and fabric filters consistently show high Hg removal rates with
a wide range of coals. The BTF limit may be achievable through other means, such as a wet scrubber
with bromide addition. In other cases, halogen addition to promote Hg oxidation and capture may be
beneficial. ACI is a proven, mature technology for capturing Hg.49 Comments claiming BTF Hg
emission rates for lignite fuels as financially impractical and technically unattainable are unfounded.
Commercial products exist to augment50 Hg capture by ACI - such as Toxecon™ for hot side ESPs,
halogen addition for PRB,51 brominated sorbents for low chlorine fuels.52 Sources may also blend fuels
as part of a compliance approach.

49 NESCAUM report; "Control Technologies to Reduce Conventional and Hazardous Air Pollutants
from Coal-Fired Power plants" p. 19, March 31, 2011

50ICAC Report: "Enhancing Mercury Control on Coal-Fired Boilers with SCR, Oxidation Catalyst and
FGD"

51 NESCAUM report, op. cit., p.20

526


-------
The EPA acknowledges lignite coal may contain increased Hg levels and display greater Hg variability
than PRB or bituminous fuels; however, these two aspects do not make BTF emission rates unattainable
or financially prohibitive. ACI selectively captures the oxidized form of Hg regardless of fuel source or
rank.53 Yet, the presence of S03 interferes with Hg capture and requires removal to avoid high activated
carbon injection rates.54 Furnaces discharging high concentrations of elemental Hg are indicative of low
chlorine content fuels (like Texas lignite) and impede ACI performance; under these circumstances,
chemical addition to promote oxidization (such as a halogen, as cited earlier) improves performance.
Halogens can be inserted: pre-combustion (added to fuel), during combustion (furnace insertion), post
combustion (gas stream injection) or through carbon impregnation.55'56 Meanwhile, adjusting carbon
injection rate will compensate for fuel Hg variability. Consequently, the EPA maintains current
technology allows BTF Hg capture rates as proposed. See the preamble for the final rule for further
discussion.

9. Coal rank/type.

Comment 46: Commenter 17757 explains that coal rank or type has an impact on the design and
operation of boilers and associated control equipment. The commenter believes the EPA has not
considered the costs of boiler modifications and control technology retrofits in the proposed rule with
respect to the coal rank and related factors. The commenter believes these distinctions should be
considered and points out that they were factored into the emission rates for the acid rain program and
prior Hg proposals issued by the EPA.

Response to Comment 46: EPA notes that the statutory requirements for the Acid Rain Program are
distinguishable from standards under CAA section 112. The EPA addresses subcategorization issues
elsewhere in the final rule record.

Comment 47: Commenter 17796 states that the cost and degree of Hg reduction depends on coal type
and additional costs to upgrade particulate pollution control to accommodate additional particle loading
from ACI. The commenter references a DOE study finding that western coal with low chlorine levels
emits higher amounts of elemental Hg, and is more readily controlled with ACI impregnated with
bromine, with one example facility estimate of $26,200/lb of Hg controlled at 90% using halogenated
activated carbon. The DOE estimated the beyond-the-floor option to be $22,496/lb of Hg removed. The
most recent report cited states that "the ACI systems have the potential to remove more than 90% of the
Hg in many applications based on results from NETL's field testing program, at a cost estimated to dip
below $10,000/lb of Hg removed. However while the results achieved during NETL's field tests met or
exceeded program goals, only through experience gained during long term continuous operation of these
advanced technologies in a range of full-scale commercial applications will their actual costs and
performance be determined."

Response to Comment 47: The EPA thanks the commenter for the comments submitted.

52	Assessment of Technology Options Available to Achieve Reductions of Hazardous Air Pollutants,
URS Corporation, April 5, 2011, http://www.supportcleanair.com/resources/studies/file/4-8-ll-
URSTechnologyReport.pdf

53	NESCAUM Report, op. cit., pp. 19-20

54	Ibid. p. 19

55	Solvay Chemicals publication "Mercury (Hg)"

56ICAC Report, op. cit.

527


-------
Comment 48: Commenter 17807 discusses the lower chloride coals ranging from 0.05 to 0.10% in the
Illinois basin, but states that it would be difficult to obtain necessary chloride levels to achieve
compliance with the proposed HC1 emission limit. The commenter goes on to say that other facilities
will be faced with similar issues and will need to consider other coal sources to achieve compliance with
the HC1 limit, which will increase demand and impact long term availability of these coals and decrease
fuel procurement flexibility and reliability.

Response to Comment 48: The EPA determined further fuel subcategorization is unwarranted. The
EPA addresses subcategorization elsewhere in the final rule record.

Comment 49: Commenter 18033 quotes the EPA position stated in CAMR, "[a]t some point in the
future, the performance of control technologies on Hg emissions could advance to the point that the rank
of coal being fired is irrelevant to the level of Hg control that can be achieved... " The commenter states
that while controls for Hg emissions have arguably reached this point based on the proposed MACT
standard, this is not the case for acid gas control for higher sulfur coals. If a well-controlled unit burning
higher sulfur coals cannot meet the standard, the commenter believes the EPA needs to revise the
proposed rule accordingly through further subcategorization to ensure that all coals are able to meet the
applicable standards.

Response to Comment 49: The EPA determined further coal subcategorization is unnecessary for
compliance since commercially available technologies for S02 control exhibit superior removal
performance for MATS acid gases.57 For scrubbed units firing high sulfur coals, sufficient MATS acid
gas capture is expected for compliance.58'59 The EPA addresses subcategorization issues elsewhere in the
final rule record.

Comment 50: Commenter 17775 commissioned a consultant to conduct IPM modeling runs using
control technology assumptions the commenter considers to be more realistic than those chosen by the
EPA. The modeling involved three runs to evaluate the consequences of the EPA's decision to regulate
all HAP, not just Hg. The commenter says the reference case was run assuming CAIR was implemented
in 25 states and the District of Columbia, and one sensitivity run assuming that the proposed Transport
Rule would be implemented with the proposed rule with only Hg emission limits. The final run was the
same as the sensitivity run, except that the proposed rule was assumed to cover all HAP. The commenter
states that the run results show that regulation of the non-Hg HAP adds approximately $10.5 billion to
the total system costs in the first years of compliance and over $8 billion annually in following years
with the 2030 compliance cost difference at over $9 billion annually. Together with the proposed rule,
the Transport rule was estimated to add $22.2 billion to total system costs in 2015, $21.1 billion by 2020
and $25.7 billion annually by 2030.

Response to Comment 50: The EPA has updated its modeling in the final rule, compliance costs are
found in the RIA and the preamble for the final rule.

The agency received numerous comments regarding independent modeling analysis performed by
commercial entities to contest EPA's IPM results. The EPA contends these sources incorporate

57	"Assessment of Technology Options Available to Achieve Reductions of Hazardous Air Pollutants"
by Lipinski, Leonard, Richardson; published by URS; April 5, 2011

58	Ibid.

59	NESCAUM report; "Control Technologies to Reduce Conventional and Hazardous Air Pollutants
from Coal-Fired Power plants" p. 19, March 31, 2011

528


-------
inaccuracies within their models which dramatically influence the basis of these comments. For a
discussion addressing the limitations of industry performed modeling studies, see the preamble for the
final rule.

Comment 51: Commenter 19114 feels revisions are needed for the inputs to the IPM model. The
commenter gives the SCR cost estimates as an example, as they are below industry estimates for
installed costs and should be increased by at least 20%. The commenter also states that it is unclear if the
EPA is correctly accounting for allowance for funds used during construction (AFUDC) and owner's
cost on fabric filter retrofits. The commenter also asks if ACI and DSI costs include transfer, handling
and storage. The commenter gives the example of IPM model results for Northeastern unit 3-4, which
showed they could comply with the proposed rule using DSI. However, the commenter states that in
March 2011, the EPA issued a Federal Implementation Plan requiring FGDs to reduce SO2, making the
HAP scenario proposed by the EPA unrealistic. The commenter asks that the EPA reevaluate its
modeling with correct inputs based on all current and proposed rules.

Response to Comment 51: IPM calculates fabric filter AFUDC correctly for a 2-year construction
cycle; the typically anticipated cycle for a fabric filter.60 The B2 calculation description (as illustrated on
the spreadsheet view) is in error. The mathematical calculation actually performed is: B2 = 6% x
(CECC+B1) {incorrectly typed as: 6% x CECC + Bl}.

Both ACI and DSI estimated costs calculations include all equipment from unloading to injection.

Due to surrogacy co-benefit effects of controls, FGD controls capture HAP acid gasses more efficiently
than SO2.61 Depending upon a unit's control configuration, equipment performance and fuel
characteristics, ACI may be unnecessary.62

Comment 52: Commenter 19114 expresses concern that the gas supply curves in the IPM model are
short on supply and inelastic in the near-term, based on comparison with data from EIA's 2011 Annual
Energy Outlook. The commenter disagrees that gas prices have the most significant impact on unit
retirements and considers the exposure of a coal unit to future environmental constraints and potential
expenditures to be the biggest factor in retirements. As such, the commenter suggests the EPA include
future regulatory constraints within the model or risk understating the impact of the rule being proposed.

Response to Comment 52: Besides retrofit controls, payroll, debt service, and maintenance, an EGU's
largest fiscal expense is fuel procurement with market conditions determining operational viability of an
EGU. The EPA approached gas supply market conditions conservatively. The agency has fully
documented its assumptions and framework for modeling natural gas in IPM for both the proposed and
final MATS. This information can be found in Chapter 10 of the IPM documentation
(http://www.epa.gov/airmarkets/progsregs/epa-ipm/docs/v410/Chapterl0.pdf). The documentation
provides a thorough overview of the natural gas module, describes the very detailed process-engineering
model and data sources used to characterize North American conventional, unconventional, and frontier

60	Sargent & Lundy, "IPM Model - Revisions to Cost and Performance for APC Technologies Particle
Matter Control Cost Development Methodology FINAL," March 2011, Project 12301-009, Perrin
Quarles Associates, Inc

61	Assessment of Technology Options Available to Achieve Reductions of Hazardous Air Pollutants" by
Lipinski, Leonard, Richardson; published by URS; April 5, 2011

62	NESCAUM report; "Control Technologies to Reduce Conventional and Hazardous Air Pollutants
from Coal-Fired Power plants" March 31, 2011

529


-------
natural gas resources and reserves and to derive all the cost components incurred in bringing natural gas
from the ground to the pipeline. Also documented are the resource constraints, liquefied natural gas
(LNG), demand side issues, the natural gas pipeline network and capacity, procedures used to capture
pipeline transportation costs, natural gas storage, oil and natural gas liquids (NGL) assumptions, and key
gas market parameters. Current and projected natural gas prices significantly impact anticipated coal-
fired retirements. IPM Natural Gas (NG) modeling is discussed in the preamble for the final rule.

Comment 53: Several commenters (19536, 19537, 19538) discuss the EPA's documentation of IPM
modeling that shows the EPA found that the costs of complying with a 0.0001 lb/MMBtu HC1 MACT
limit, which would be achieved through installation of scrubbers or scrubber upgrades, installation of
baghouses at fluidized bed boilers, and/or DSI with baghouses to achieve SO2 removal efficiencies of
92% to 96%, would be cost effective. The commenters point out that the EPA did not account for the
fact that numerous units will have to achieve the required level of SO2 controls soon under other state or
federal regulation to meet ambient air quality standards. The commenter goes on to list additional
findings by the EPA based on IPM modeling, and agrees with the EPA's assessment that the
environmental and health benefits outweigh the costs, thanks to the cost-effective technologies and
methodologies summarized.

Response to Comment 53: The EPA thanks the author for the comments submitted.

The EPA's IPM modeling of MATS accounts for all finalized state and federal regulations. See RIA
chapter 3 and "Documentation Supplement for EPA Base Case v.4.10_MATS - Updates for Final
Mercury and Air Toxics Standards (MATS) Rule" for additional discussion.

10. Difficulties with control technologies.

Comment 54: Commenter 17702 acknowledges that they have compliance options to meet the proposed
emission reduction requirements, such as adding carbon injection or switching to a wet scrubber.
However, the commenter points out that these options will increase cost and defeat the environmental
objectives because they will increase water use and eliminate the sale of the byproduct material from a
dry fabric filter.

Response to Comment 54: The EPA does not anticipate units with fabric filters necessarily increasing
water consumption because scrubber retrofit becomes unnecessary with the DSI option for rule
compliance. Depending upon treatment rate and reagent (sorbent) selected, ACI or DSI may impact fly
ash sales; on the other hand, activated lime reagent effectively removes acid gases and should not
adversely impact fly ash marketability. Mineral-based Hg sorbents are effective and commercially
available for overcoming concerns with activated carbon.63 Additionally, see response to comment 4
(above).

Comment 55: Multiple commenters (17868, 17912, 19213) state that the EPA did not address physical
space and age-of-plant issues when setting BDT, MACT, and NSPS because it did not recognize that
older coal-fired power plants have space constraints and may only be able to "build up" if they install a
fabric filter. This means that smaller and older plants will not be able to comply with the proposed rule.
Commenter 17868 considers the EPA's projection that only 3% of the industry's coal-fired capacity will

63 Hizny, W., Magno, G., Yang, X., "BASF Mercury Sorbent ZX™ for Control of Coal-fired Power
Plant Hg Emissions," Paper # 176, Power Plant Air Pollutant Control "MEGA" Symposium, August 30
- September 2, 2010, Baltimore, MD

530


-------
become uneconomical due to the proposed rule to be flawed and also points out that the EPA did not
identify how many of the public power units will implement control technologies under separate
regulations or state implementation plan changes and revisions to effluent guidelines which may take
power plants offline for weeks or months in the next 5 or more years. Commenter 17868 believes the
EPA's estimates of the number of plants that will require additional controls, and these impacts will hit
the upper and lower midwest, southeast, and southwest the hardest.

Response to Comment 55: For discussion on available space limitations, small stations, small
companies and control equipment available, see Response to Comments section 5C01 "Compliance
Dates" which discusses controls for congested sites and combing emissions from multiple units into a
single control device. Additional discussion is provided in the preamble for the final rule.

The agency accounts for current state air emissions regulations in its IPM modeling platform; for
detailed discussion, see RIA chapter 3 and "Documentation Supplement for EPA Base Case
v.4.10_MATS - Updates for Final Mercury and Air Toxics Standards (MATS) Rule."

Comment 56: Commenter 18433 states that the suggested method of controlling PM emissions from
oil-fired units is ESP because the PM is generally too "sticky" from organic content to be collected
reliably in fabric filters due to plugging the pore holes in the bags.

Response to Comment 56: The EPA thanks the submitter for their input. The agency responded by
creating a subcategory for liquid oil-fired, non-continental units (not including Alaska-based units) - see
final rule. Additionally, the final regulation will change the PM standard from total PM to filterable PM.
The EPA acknowledges oil-fired units typically control PM emissions with an ESP and believes the
final MATS standard for oil-fired units can be met with a well-designed, well maintained ESP for
maintaining PM control. The EPA does not select any specific technology for MATS compliance; rather
the standard sets permissible emission rates which allow the owner flexibility in selecting controls and
fuels for compliance. See the preamble for the final rule.

11. Natural gas prices.

Comment 57: Commenter 17810 does not believe that the EPA has adequately considered the best
available data on natural gas prices and supply, and requests that the EPA perform additional analyses of
control options using updated information.

Response to Comment 57: The agency has fully documented its assumptions and framework for
modeling natural gas in IPM for both the proposed and final MATS. This information can be found in
Chapter 10 of the IPM documentation (http://www.epa.gov/airmarkets/progsregs/epa-
ipm/docs/v410/Chapterl0.pdf). The documentation provides a thorough overview of the natural gas
module, describes the very detailed process-engineering model and data sources used to characterize
North American conventional, unconventional, and frontier natural gas resources and reserves and to
derive all the cost components incurred in bringing natural gas from the ground to the pipeline. Also
documented are the resource constraints, liquefied natural gas (LNG), demand side issues, the natural
gas pipeline network and capacity, procedures used to capture pipeline transportation costs, natural gas
storage, oil and natural gas liquids (NGL) assumptions, and key gas market parameters.

Comment 58: Commenter 18033 considers replacing coal with natural gas to be problematic given that
the cost of natural gas is volatile and makes up over 70% of the levelized cost of electricity (LCOE). The
commenter describes a price spike from $6/MMBtu to $13/MMBtu in 2005 and details some of the

531


-------
environmental issues recently created by harvesting shale reserves. The commenter asks the EPA to
examine a constructive policy framework that removes this and other regulatory impediments and
promotes the deployment of advanced coal technologies. The commenter states that replacing older U.S.
coal plants with advanced supercritical generation could create $1.2 trillion in economic benefits and 6
million jobs during construction as well as avoiding the release of 440 million metric tons of CO2.

Response to Comment 58: The agency fully documents its assumptions and framework for modeling
natural gas in IPM for both the proposed and final MATS. This information can be found in Chapter 10
of the IPM documentation (http://www.epa.gov/airmarkets/progsregs/epa-

ipm/docs/v410/Chapterl0.pdf). The documentation provides a thorough overview of the natural gas
module, describes the very detailed process-engineering model and data sources used to characterize
North American conventional, unconventional, and frontier natural gas resources and reserves and to
derive all the cost components incurred in bringing natural gas from the ground to the pipeline. Also
documented are the resource constraints, liquefied natural gas (LNG), demand side issues, the natural
gas pipeline network and capacity, procedures used to capture pipeline transportation costs, natural gas
storage, oil and natural gas liquids (NGL) assumptions, and key gas market parameters.

12. Fuel switching.

Comment 59: Commenters 18433 and 19213 disagree with the assumption that all coal and fuel-oil
units can be used with available control technologies. The commenters state that such fuel switching
from one fuel type to another or fuel blending can be expensive, and facilities in Guam are restricted in
their fuel choices and must rely on oil currently.

Response to Comment 59: The difficulties American territories experience is acknowledged. The
agency created a subcategory for oil-fired, non-continental units (excluding Alaska-based units)
realizing the unique situation and limitations these units face - see final rule. The MATS standard
allows the owner flexibility to select controls and fuels plus establishes alternatives for compliance. See
the preamble for the final rule.

Comment 60: Commenter 19114 expresses concern with the IPM analysis suggesting that units will
switch fuel to meet the beyond-the-floor standard. The commenter considers this unreasonable because
fuel switching could change the subcategory of the unit, thus subjecting it to a more stringent Hg limit.
Also, the commenter points out that fuel switching costs used by the EPA do not account for all required
coal conversion activities or for projects such as new coal unloading and coal yard facilities to
accommodate subbituminous coal which is often delivered by rail instead of truck or conveyor like
lignite fuel generally is. Additional facility upgrades that the commenter would like to see in the EPA's
estimate include dust collection, new coal conveyers, fire protection, ventilation, ESP performance and
water cannons to handle new fuel, soot and ash characteristics.

Response to Comment 60: Compliance issues, subcategories, and beyond-the-floor (BTF) issues are
discussed elsewhere in the final rule record.

The agency believes that the fuel switching costs used in IPM are accurate, as explained at proposal.
That said, the final rule does not require fuel switching, instead we establish numeric emission standards
and sources are required to comply in any manner they choose. The IPM modeling indicates that some
sources may choose to switch fuels as a valid compliance option. If sources are unable or unwilling to
employ fuel switching, they can comply through the installation of controls or other means available to

532


-------
reduce HAP emissions. We discuss fuel switching as a compliance option elsewhere in the final rule
record.

Comment 61: Commenter 17621 notes that the following comment presents the commenter's
observations and experience with this [EPA's] approach to reducing HC1 at a site burning Powder River
Basin (PRB) coal and another site burning an eastern bituminous coal. Both of these studies were short-
term in nature, with the test period of several weeks, evaluating a number of different parameters each
day. Thus these results are not able to provide any insight on the long-term performance and impacts of
dry sorbent injection. The commenter is not aware of other demonstrations of this approach that have
been conducted by independent, third parties. However, because of their citation in the technical
supporting documents for the proposed MACT rule, we also discuss tests conducted by a sodium sorbent
supplier.

The commenter participated as a technical advisor in the first commercial demonstration of the
TOXECON(r) process at We Energies' Presque Isle Power Plant. The project was co-funded by DOE
under the Clean Coal Power Initiative. The primary objective of the project was to demonstrate the
TOXECON configuration-downstream of a hot-side ESP in this case-with ACI for Hg control. A
secondary goal was to determine the ability of powdered Trona injection to reduce SO2 by 70% and also
to realize some NOx emission reductions. These pollutant reductions were to be obtained while
simultaneously injecting activated carbon for Hg control (ADA-ES, 2008). The tests showed that the
Trona could reduce S02, but that it also converted enough nitrogen oxide (NO) to nitrogen dioxide
(NO2) to produce a visible brown plume. Trona injection also reduced Hg capture by ACI significantly.
Without Trona injection, the Presque Isle unit was able to maintain 90% Hg reduction at ACI rates of 1
to 2 pounds per million actual cubic feet (lb/MMacf). During Trona testing, the unit was unable to
achieve a 90% Hg removal over a short 1-hour test, even when the ACI rate was increased to 4.6
lb/MMacf.

As these tests were conducted before the EPA made known its intent to regulate acid gases from EGUs,
the project did not measure HC1 emissions-especially not as a function of activated carbon sorbent
injection rate. Therefore, these tests do not inform us about the amount of Trona or sodium bicarbonate
that would be needed to meet the proposed HC1 limit, nor whether that amount would cause a brown
plume and/or plugging, as well as impact Hg capture by ACI. Tests by Solvay Chemicals (a major
supplier of Trona and sodium bicarbonate) at a low-sulfur eastern bituminous-fired power plant
(reporting ~ 0.5-1% sulfur in the coal and 50-60 ppm HC1 in the flue gas) may provide some clues. In
this one test campaign, Solvay Chemicals reported 50% HC1 removal at a sodium bicarbonate injection
rate sufficient to capture 10% of the S02-i.e., a relatively low injection rate (Davidson, 2010).

Since brown plumes have been observed at plants using sodium sorbents for SO2 control, but not at
plants using these sorbents for SO3 control, it is possible that low sodium injection levels may not
produce brown plumes or plugging; this may apply for western bituminous coals with coal chloride
concentration slightly greater than the proposed limit for HC1. However, this may not be possible for
subbituminous coals with chloride concentration greater than about twice the proposed limit, where HC1
removals up to 90% may be required. The situation for eastern bituminous coals, with their higher
chlorine content, is discussed below. To go beyond a reliance on engineering judgment, it is important to
determine-via independent tests fully open to public scrutiny-whether these single results obtained on an
eastern bituminous coal are representative of results for the fleet of PRB-fired power plants. Only then
will the public and the industry truly understand the ability of sodium sorbent injection combined with a
fabric filter to reduce HC1 emissions to the proposed limit at plants burning western coals, and to do so
without impacting plume opacity and/or Hg emission reductions.

533


-------
In 1996-97, the commenter conducted tests of both sodium bicarbonate and hydrated lime DSI upstream
of a pilot baghouse at Hudson Generating Station owned by Public Service Electric and Gas (EPRI,
1998). This plant burned a coal that typically contained less than 1.0% sulfur and less than 0.1%
chlorine; the corresponding flue gas HC1 concentration at the pilot's inlet duct was 61-97 ppm. The
results of these tests, presented in the document, show that HC1 reductions up to 90% could be achieved,
but only at sorbent-to HC1 injection ratios of about 12. For a 500 MWe plant with 100 ppm HC1, a
normalized stoichiometric ratio (NSR) of 12 is equivalent to increasing the ash loading by 50-60% or by
250-300 tons/day (normal ash loading is about 500 tons/day).

The Hudson site, with an HC1 concentration in the mid-range for eastern bituminous coals, would have
required 97-98%) HC1 removal to achieve the proposed MACT limit (equivalent to ~ 2 ppm). Plots of
pollutant removal versus sorbent injection rate typically become very flat at high injection rates-i.e.,
increase very slowly if at all with increasing sorbent injection-so it is not clear from the available data if
hydrated lime or sodium bicarbonate could routinely provide greater than 90% reductions at any
injection rate.

Response to Comment 61: The EPA appreciates the commenter's observations. See the preamble for
the final rule for more discussion on DSI technology.

13. Miscellaneous.

Comment 62: Commenter 18033 questions the EPA assumption that 50% or more of the current fleet
have scrubbing technology installed and that the number will be nearly two-thirds by 2015. The
commenter says that over half of the scrubbers mentioned will be at the end of their useful life by 2015,
so cost will be associated with upgrading these scrubbers to achieve compliance. Also, the commenter
points out that the scrubbers were only required to achieve 70% SO2 removal when constructed.

Bringing these scrubbers into compliance will require more than modifying spray heads and adding
absorber trays and could double the projected upgrade costs for older units and increase retirements.

This leads the commenter to conclude that approximately 25% of the current coal-fired fleet will retire
early as a result. The commenter also mentions that as the MACT floor is set on the average of the top
12%), only 6% can be expected to meet the standard without modification.

Response to Comment 62: The agency has a different outlook regarding replacement of existing
control equipment. The EGU sector continuously demonstrates the ability to operate equipment beyond
its originally intended lifespan (typical design life of 30 years) through replacement or upgrade of worn
components. For example, 592 units (59% of the coal fired fleet) exceed 40 years of age.64
Consequently, the agency believes owners will operate emissions control equipment well beyond a 20-
year period and shall attempt the more economically attractive option of upgrading equipment rather
than replacement. Depending on scrubber age and current SO2 removal rates, a wet scrubber can be
upgraded for $5-$ 100 per kW of unit size.65 Furthermore, for acid gas removal compliance, an owner's
option includes augmenting existing controls by installing DSI.

64	M.J. Bradley & Associates Report; "Ensuring a Clean, Modern Electric Generating Fleet while
Maintaining Electric System Reliability," August 2010, p. 16; Table 5 "Characteristics of U.S. Coal
Plants." Ref:

http://www.mibradlev.com/sites/default/files/MJBAandAnalvsisGroupReliabilitvReportAugust2010.pdf

65	Assessment of Technology Options Available to Achieve Reductions of Hazardous Air Pollutants" by
Lipinski, Leonard, Richardson; published by URS; April 5, 2011

534


-------
Comment 63: Commenter 18023 reports that many of their units have SCRs and scrubbers but will not
be able to meet proposed emission limits in most cases and will need baghouses and CEMS installed at a
cost of $8.5 billion to comply with the proposed limits and monitoring requirements. The commenter
notes that this price could increase due to the large number of plants rushing to comply with all existing
and proposed regulations which could drive up the costs of materials and skilled labor. The commenter
also shows that the EPA's estimate for the same facilities gives a $4 billion cost, showing that the EPA's
estimates are understated.

Response to Comment 63: The EPA disagrees with commenter's assertion that the EPA's cost
projection is understated, and maintains that the EPA's incremental cost projections are reasonable. The
RIA includes projected controls retrofits and costs as updated in the EPA's analysis for the MATS final
rule. The EPA has provided the maximum 3-year period for sources to come into compliance. Sources
may also seek a 1-year extension of the compliance period from their Title V permitting authority if the
source needs that time to install controls. The EPA will work with relevant authorities to ensure a
smooth transition with this rule and address specific issues. For discussion on some of the issues
mentioned above, see the preamble for the final rule and Response to Comments section 5C01
"Compliance Dates." In addition, there are certain provisions for granting utilities some additional time
to comply, if conditions warrant (see preamble).

Comment 64: Commenters 16826 and 17386 consider the cost and logistic burdens to comply with the
proposed rule a concern because they know of a unit containing a once-through circulating water system
that must meet NPDES water discharge limits. The commenters say that these permit limits indirectly
restrict the hours of operation and load, and request a "Limited Use" category to relieve this and other
oil-fired facilities in a similar scenario.

Response to Comment 64: Based on the concerns submitted, the EPA established a "limited-use"
subcategory for liquid oil-fired EGUs. For a detailed discussion, see the preamble to the final rule.

Comment 65: Commenter 16849 reports a compression of resources available between 2007 and 2008
that led to the price of SCR installation to jump from $31 million in 2007 to $58 million in 2008 at a
neighboring, like-sized facility.

Response to Comment 65: Many factors influence retrofit cost besides locality;66 a neighboring facility
does not necessarily mean an "identical" facility. The present economic conditions differ drastically
from the situation experienced in 2007-2008; retrofit controls cost models were determined during this
time period and based on 2009 pricing. With excess resources currently available, the agency anticipates
aggressive competition by suppliers to win project award subsequently resulting in price relaxation from
pre-2009 levels.

Comment 66: Commenter 17296 provides information regarding the use of calcium bromide as a cost-
effective way to reduce Hg emissions from coal-fired units. The commenter says that calcium bromide
has been found to effectively oxidize elemental Hg so that it can be better controlled by traditional
control devices. (The commenter provides a White Paper on Calcium Bromide Technology for Mercury
Reductions (August 2010) as part of EPA-HQ OAR-2009-0234-17296-A5 and additional research as -
17296, -17296 and refers to NESCAUM report "Technologies for Control and Measurement of Mercury
Emissions from Coal-Fired Power Plants in the United States: a 2010 Status Report" at
http://www.nescaum.org/topics/mercury.)

66 Steam, 41st Ed. 2005, Babcock & Wilcox Company

535


-------
Response to Comment 66: The EPA thanks the submitter for the information provided in support of the
proposed rule. Multiple comments were received advocating control technologies that were not
represented in the EPA's compliance cost analysis of the MATS proposal. The agency notes that control
technologies mentioned within the proposal are neither an exhaustive nor an exclusive list, rather, these
listings demonstrate proven available technologies for industry sector compliance. The EPA is not
selecting, or precluding, any particular technologies in this rulemaking but is instead allowing each
facility to determine its preferred means of compliance with the emission rate standards.

Comment 67: Commenter 17807 discusses a new $1.2 billion project to upgrade environmental controls
and repower a power station which led to an annual reduction of Hg, SO2, NOx and PM emissions in
2010 by 90%, 94%, 91% and 87%, respectively, below 1998 levels. The commenter says that the EPA's
proposed emissions limits will likely require further optimization and adjustments and be difficult to
implement despite these recent upgrades.

Response to Comment 67: The agency set emissions standards based on data collected (ICR) from
existing EGUs within the domestic EGU fleet; thereby, demonstrating operational, existing control
technologies for compliance. Owners have a multitude of options and may choose to: retrofit, optimize
current controls, upgrade existing controls, fuel switch/blend, employ a combination of technologies, or
retire and replace power. The EPA understands recently retrofitted units may require further upgrades
for compliance; however, controls for SO2 mitigation typically suffice for MATS acid gas capture while
economical upgrades of existing controls or optimization may suffice for compliance.67

Comment 68: Commenter 17842 believes the implementation of a "total" PM limit in the proposed rule
contributes largely to the rule's estimated costs as utilities will need to replace existing PM controls with
more costly fabric filters.

Response to Comment 68: Although the EPA proposed a total PM standard, the EPA is finalizing
MATS to include a filterable PM standard instead. See the preamble for the final rule. The EPA does not
believe that MATS automatically necessitates replacing existing PM controls with fabric filters. Many
older ESPs are oversized and suffer from inadequate maintenance resulting in degraded performance;
simply restoring performance will improve capture rates. Upgrading with modern components (such as:
modern power supplies, electrode replacement, additional fields) or enhancing air flow and rapping
allows improvement beyond original performance metrics. In fact, many older ESPs have sufficient
room for extension thereby increasing collecting area by 10-20 percent.68 As another option, an EGU
may consider retaining the old ESP and install a supplemental smaller-sized "polishing" baghouse69 to
augment particulate collection. In short, the EPA does not foresee ESPs becoming obsolete with
promulgation of MATS.

Comment 69: Commenter 17885 states that many cooperative EGUs will be forced to retrofit with
additional emission controls under the proposed rule and others will need to shut down because they will
be unable to retrofit under the timelines or cost-effectively justify the retrofits. The commenter expresses

67	Assessment of Technology Options Available to Achieve Reductions of Hazardous Air Pollutants" by
Lipinski, Leonard, Richardson; published by URS; April 5, 2011

68	Assessment of Technology Options Available to Achieve Reductions of Hazardous Air Pollutants" by
Lipinski, Leonard, Richardson; published by URS; April 5, 2011

69	NESCAUM report; "Control Technologies to Reduce Conventional and Hazardous Air Pollutants
from Coal-Fired Power plants" p. 19, March 31, 2011

536


-------
concerns with the practical application of the proposed rule and the procedures used by the EPA in the
rulemaking process.

Response to comment 69: The EPA believes that the flexibility of the rule permits a multitude of
options for economical compliance. Flexibility, other regulations, and compliance date attainment are
discussed in the preamble for the final rule, feasibility TSD, and in Response to Comments section 5C01
"Compliance Dates."

Comment 70: Commenter 19122 describes the startup and shutdown process for their oil-fired unit,
which requires bypassing of the fabric filters to prevent damage that would require replacement of bags
after each startup. Requirements that include startup and shutdown episodes in PM emissions on a
lb/MMBtu basis would lead to the need to use the fabric filter with temperatures well below the acid
dew point, leading to bag binding and acid degradation. The commenter explains that this would involve
using at least one casing out of three in service to handle flow during start up. One casing has 16
compartments with 396 bags each. The bags in the compartment that would need replacement cost $1.2
million, leading to an additional cost of $15 million per year.

Response to Comment 70: The EPA acknowledges start-up/shut down issues involving fabric filters
(acid attack, blinding, etc.) during oil firing. The agency points out that the coal-fired boiler industry
overcame this issue by installing chemically resistant bags70 and/or pre-coating the bags71 with an
alkaline powder. Another option employs firing low sulfur fuels. Additionally, the EPA established
requirements for PM control during start-up, shutdown and malfunction - see the preamble for the final
rule.

70	Neundorfer web site: http://www.neundorfer.com/knowledge base/baghouse fabric filters.aspx ;
Lesson #4, p.7 Table 4-1 [ref.:

http://www.neundorfer.eom/FileUploads/CMSFiles/Fabric%20Filter%20Materiair01.pdf1

71	CoalPower mag; May 1, 2007; "Coal Plant O&M: River Locks and Barges are an Aging Workforce,
Too" ref.: web site: http://www.coalpowermag.com/plant design/Coal-Plant-O-and-M-River-Locks-
and-Barges-Are-an-Aging-Workforce-Too 36.html

537


-------
6G - Impacts/Costs: Testing and Monitoring Cost Assumptions

Commenters: 17197, 17386, 17681, 17696, 17716, 17718, 17730, 17737, 17761, 17772, 17795, 17796,
17843, 17856, 17881, 17886, 18014, 18444, 18502, 18023

Comment 1: Commenter 17197 believes the 18 months burner inspection interval is unreasonable
because it introduces substantial costs not reflected in the cost estimates shown in Table 14 of the
proposed rule. The commenter reports costs for pre-boiler entry slag blasting for personnel safety costs
approximately $10-12,000, scaffolding the boiler for burner access is about $80,000 and requires at least
6 weeks of pre-planning and post-outage boiler combustion testing and tuning costs around $50,000.

Response to Comment 1: The EPA generally agrees with the commenter and has altered the burner
inspection interval to reduce the cost burden of this rule. Under the final rule, the inspection and tune-up
must be conducted at each planned major outage and in no event less frequently than every 36 months,
with an exception that if the unit employs a neural-network system for combustion optimization during
hours of normal unit operation, the required frequency is a minimum of once every 48 months.

Comment 2: Commenter 17386 objects to the requirement to conduct monthly or bimonthly
performance tests, as it is an economic burden, especially for smaller facilities. The commenter also
states that such testing could result in increased annual HAP emissions exceeding any reduction in
hourly emission rates achieved by the rule. The commenter points out that oil is a homogenous fuel for
which metal concentrations are unlikely to fluctuate. The commenter goes on to say that since oil-fired
EGUs are a minor source of HAP except for nickel, the frequent testing is unwarranted. The commenter
states that the cost of such a testing program involves the ancillary cost of operating the EGU on a must-
run basis for the testing, even on EGUs that operate intermittently. Such testing will interfere with the
ability to meet regional electricity demands if the EGUs have a monthly circulating water flow limits as
part of their NPDES permit. The commenter also notes a problem for dual-fired EGUs which often
operate on natural gas during the ozone season. However, for testing purposes, the commenter will be
required to fire the fuel with the capacity to generate the most HAP emissions, leading to emissions that
would not have otherwise been released. The commenter requests that for these reasons, the EPA require
only one performance test for oil-fired EGUs be conducted every 3 years.

Response to Comment 2: The EPA recognizes the cost burden of testing and we are relaxing the testing
frequency to require that oil-fired EGU's be tested at least quarterly rather than monthly or bimonthly.
The EPA generally agrees with the comment regarding oil-fired testing during the ozone season and is
changing the rule language accordingly to require that testing be conducted on the fuel type fired during
the operating quarter that is likely to result in the highest emission rate. In this manner, if there are no
oil-fired operations during ozone season quarters, there is no requirement to test while firing oil.

Comment 3: Commenters 17386 and 17696 consider monthly or bimonthly stack testing for HC1 to be
wasteful due to high annual costs of around $78,000 for a single stack, $127,000 for two stacks and
$176,000 for three stacks. The commenters believe that a more reasonable approach would be to
perform an initial stack test for PM followed by the use of PM CEMS, and annual PM stack tests as long
as the coal type or mixture of fuels did not change. The commenters state that a stack test vendor
estimates that annual total PM and non-Hg metals stack testing plus non-Hg metals bimonthly stack
testing would impose a cost of $67,000 for one stack, $115,000 for two stacks and $162,000 for three
stacks, which would be unnecessary to assure compliance if the suggested approach were used.

538


-------
Response to Comment 3: The EPA disagrees with the commenters' notion that PM is an appropriate
surrogate for HC1 emissions. HC1 testing frequency has been reduced to a quarterly requirement and is
required only if SO2 controls and monitoring, or HC1 monitoring (optional) are not employed. PM
CEMS and PM CPMS options are being added to this rule to optionally reduce the burden of monthly or
bimonthly stack testing.

Comment 4: Commenters 17716 and 18014 discuss linearity checks required under Appendix B.
Commenter 17716 states that section 63.10010(e)(6)(iii) should define the term "nominally," and should
not require the introduction of a calibration gas. The commenter points out that Part 75 requirements
already assure an analyzer span that provides accurate data. Coupled with the Part 75 requirements, the
three linearity gas concentrations are sufficient to determine that the analyzer is linear. Commenter
18014 states that the system will need to be modified to include an additional regulator, the data
acquisition and handling system (DAHS) will need to be reprogrammed and costs will be incurred for a
fourth calibration gas and monthly cylinder demurrage. Both commenters state that the section 63
requirements will increase SO2 CEMS operating costs.

Response to Comment 4: The EPA agrees with the commenter that Part 75 requirements already
provide for a linear instrument response that should, by definition, include the emissions limit level and
beyond, and has removed this requirement from the final rule.

Comment 5: Commenter 17718 requests guidance from the EPA on what should be included in a site-
specific test plan mentioned in the proposed rule (40 CFR 63.10007(a)) as the development of quality
assurance programs with testing firms can be burdensome without clear guidance.

Response to Comment 5: Section 63.100007(a) points to section 63.7(c) which contains specific
information about QA programs including test plans and internal and external QA programs. The EPA is
a proponent of Data Quality Objectives (DQOs) as these are the pretest expectations of precision,
accuracy, and completeness of data.

An example of a DQO requirement is:

"The sample volume must be sufficient to provide the required amount of analyte to meet both the MDL
of the analytical method and the allowable stack emissions. It may be calculated using the following
formula:

Sample Volume = A x 100/B x 100/C x 1/D
Where:

A = The analytical Method Detection Limit in ng

B = % (%) of the sample required per analytical run

C = Sample recovery (%)

D = Allowable stack emissions (ng/dscm)

Test contractors are experienced with developing and working with Test Plans, DQOs, and QA
programs and the EPA feels this requirement should not present an undue burden to facilities.

539


-------
Comment 6: Commenter 17730 and 18023 discuss the Hg compliance options. Commenter 17730
believes that the proposed Hg emission standards for existing units is not based on representative data
and the limit will be difficult to achieve routinely and will eliminate new coal-fired units. However the
commenter appreciates the EPA's providing of the alternative of conducting fuel analysis for ongoing
compliance for existing low emitting electric generating units (LEEs), and urges the EPA to make it
available to new units as well. Commenter 18023 questions the EPA's assumption that "most, if not all,
of the units that were subject to CAMR purchased Hg CEMS and/or sorbent trap systems prior to the
rule vacatur..The commenter reports that while their facilities did install Hg CEMS, the systems will
need extensive upgrades as they will require three more CEMS be installed to meet the proposed
requirements. Also, full quality assurance measures have only been completed on a fraction of the
previously installed CEMS. The commenter goes on to say that the Hg CEMS have required an
unexpected degree of maintenance, which will increase with lowered emission limits and some Hg
CEMS have been inexplicably unreliable. The commenter believes others in the industry are in a similar
situation, which means that the EPA cost estimates underestimate the cost of new installations,
expensive upgrades and additional maintenance required by the proposed rule. In addition to the
equipment-related expenses, the commenter lists costs associated with modifying the data acquisition
and reporting systems associated with the Hg CEMS to meet the new procedures and requirements. The
commenter estimates that these changes will cost approximately $20 million upfront and another $2.5
million annually.

Response to Comment 6: The EPA generally agrees with the commenter that many Hg CEMS
installations were not undertaken or fully implemented as a result of the CAMR vacatur, and we are
increasing our estimated cost impacts accordingly. The EPA does not agree that existing mercury CEMS
installations would need upgrades to comply with this rule and the commenter provided no information
demonstrating the case.

Comment 7: Several commenters (17737, 17761, 17886, 18023) comment on the burden of outage
intervals required to meet the proposed rule requirements. Commenter 17737 reports that in addition to
the cost of the inspection and repair work, the facility may be required to purchase power during outages
at higher prices that the electricity normally produced. This cost could exceed $1 million for a 3-week
outage during peak season. By requiring a major outage every 18 months, the rule makes it difficult to
schedule outages for off-peak seasons when demand for power drops and replacement power is less
expensive. Commenter 17761 states that major maintenance outages are generally scheduled only every
4 or 5 years. The requirement to do burner inspections every 12 to 18 months is excessive because large
companies multiply these outages across a fleet of 20-30 units, making the annual costs large, increasing
electricity rates and interfering with system reliability. Commenter 17886 considers the requirement of
an outage for burner inspection and repair more often than every 36 months to be excessive because of
increased costs without actual benefit. Commenter 18023 estimates that the impact of shortening its
outage interval by only 6 months would amount to approximately $140 million for 5 years across their
system, taking into account the cost of replacement generation.

Response to Comment 7: The EPA acknowledges the concerns raised by the commenters and has
altered the requirement for burner inspections to a schedule more likely to coincide with planned major
outage schedules.

Comment 8: Commenter 17772 requests clarification on the proposed rule language that verifies no
requirement to retrofit boilers with viewing ports where none previously existed. The commenter quotes
section 63.10002 l(a)(16)(iii) and asks that the "as applicable" provision be clarified to show if it is
intended to exclude observation of flame pattern in boilers that do not have viewing ports. The

540


-------
commenter considers the addition of view ports to units without them costly and of little benefit as flame
pattern viewing can be subjective when trying to assess CO levels and tells little about NOx levels.

Response to Comment 8: The EPA generally agrees with the commenter and has revised the rule
language as suggested.

Comment 9: Commenter 17772 discusses the option of calibrating oxygen monitors instead of
calibrating all other equipment to optimize total CO and NOx emissions. The commenter recommends
that oxygen monitors be calibrated annually instead of the air flow or fuel measurement devices, as
proposed in section 63.100021(a)(16)(iii). The commenter reports that air-to-fuel ratios are usually fixed
by the manufacturer at the time of installation and calibration is done as needed or during a planned
outage. Some systems are difficult to adjust or unable to be adjusted. Therefore, the commenter
considers CO and NOx emissions to be dependent on oxygen, so monitoring oxygen levels is a better
indication of optimal emissions. In addition, oxygen sensors are more easily monitored and calibrated,
and their calibration would be a better requirement. The commenter also requests that the proposed
language in section 63.10002l(a)(16)(iv) be altered from ".. .optimization should be consistent with the
manufacturer's specification." to ".. .optimization should be consistent with burner industry operating
procedures." This wording change is important because the burners are set by the manufacturer at the
time of installation, but the operator is responsible for adjustments based on future operational changes
such as coal quality.

Response to Comment 9: The EPA generally agrees with the commenter in that not all parameter
changes are applicable at all facilities and for all burner installations. We are modifying the rule
language to clarify this requirement and allow for adjustment of burners that have had post-manufacturer
modifications or adjustments for fuel quality or type.

Comment 10: Commenter 17795 requests that the facility averaging requirement to not exceed current
emission levels be removed on the grounds that the current language penalizes units that have controls in
place and are currently meeting the EPA's HAP standards, which is counterintuitive to how these units
should be viewed. The commenter lists the following reasons for the requested change in the provision:

1.	Facilities in many cases do not have CEMS installed (e.g., Hg and PM CEMS) and do not know the
current rate being achieved at given unit.

2.	There is too much variability in emissions data to set an arbitrary emissions ceiling that may not be
reflective of the upper end of the normal range of emissions at a given facility.

3.	To demonstrate that the control technology is no less effective is in essence requiring an initial
compliance test shortly after the rule is finalized and again 3 years later when the compliance is
required. Again this scenario places too much emphasis on emissions testing and fails to recognize the
variability of those tests. The commenter includes a table which shows this potential variability and the
wide spread of Hg emissions (all within EPA's proposed Hg standard) at one of GenOn's facilities in the
first seven months of 2011. [EPA-HQ-OAR-2009-0234-17795-A1,

17795 201 l_Hg_Emission_Data.doc]

Response to Comment 10: The EPA disagrees with the comments provided. The ICR testing
requirements were designed with the goal of collecting data representative of the cross section of units.
The UPL calculation performed on emissions test data takes variability into account in the effort to find

541


-------
levels where 99% of emissions test results will fall below the set limit. Performance testing conducted to
assess control technology effectiveness are standard compliance procedure.

Comment 11: Commenter 17796 considers the option of stack testing with Method 5 or 201/202
monthly or bimonthly depending on PM control equipment to be burdensome for the source and the
state agencies required to witness the tests and review the reports. The commenter also points out that
the proposed testing does not assure additional public health benefits.

Response to Comment 11: The EPA has modified the requirement for monthly and bimonthly testing
to a quarterly testing requirement. This requirement is an option and as such is not a necessary burden
for the facility to bear. The proposed testing is in lieu of continuous monitoring and as such is meant to
assure that public health benefits are akin to what would be shown by continuous monitoring of
emissions.

Comment 12: Commenter 18023 reports that the cost to install and operate PM CEMS for compliance
with the proposed rule will exceed $30 million initially and at least $0.6 million annually.

Response to Comment 12: The EPA recognizes the costs associated with PM CEMS compliance
requirements and is modifying the rule language to reduce the cost burden while maintaining continuous
monitoring using the technology as a continuous parameter monitor (PM CPMS).

Comment 13: Several commenters (17796, 17761, 17843, 17856, 18444) comment on the costs for state
agencies required to observe or review emissions tests, read reports and protocols related to the proposed
rule, and send the EPA summaries of the data. Commenter 17843 suggests that once the initial test is
conducted for PM and non-Hg metals, and fuel sampling or operating parameters are established, fuel
sampling would be a simpler and less costly approach than stack testing. The commenter mentions that
having the EPA revise the monthly and bimonthly testing requirement to quarterly or biannual testing
would be more reasonable. Commenter 17856 also discusses the need to modify each unit's Title V
permit and the time required for state agencies to complete the extensive modifications to each unit's
unique operational characteristics. The commenter sees these requirements as especially burdensome
because they would be required to repeat the process every two months, indefinitely, and for every unit
subject to the bimonthly performance tests. The commenter states that budgetary constraints mean the
states simply do not have the resources to carry out these responsibilities, so the EPA should revise the
rule to alleviate this burden. Commenter 1844 mentions that minimum sample volume of 4 dry standard
cubic meters (dscm) means approximately 4-hour sample runs, which will increase workload. Also, the
commenter points out that some rule sections with operating limits in need of establishment will require
multiple load testing, which is another resource drain for state agencies.

Response to Comment 13: The EPA generally agrees with the comments and has dropped fuel
sampling requirements for non-Hg metals since the detection levels are not low enough to show
compliance with the limits. This removes the requirement to update Title V permits as the rule will also
drop the control device operational limits. Now, source owners/operators would establish the milliamp
value during successful Method 29 testing, and use just that value as an operating limit. The EPA has
also modified the rule requirement to require testing on a quarterly basis rather than monthly or
bimonthly. The EPA has undertaken an effort to better assess detection limits of test methods which may
serve to reduce the 4 dscm requirement in the future.

542


-------
Comment 14: Commenter 17881 requests a change to report a total for all metals, rather than reporting
filterable and condensable values because the separate analysis will add costs without providing
necessary information.

Response to Comment 14: The EPA disagrees with the comment and is not modifying the requirement.
EPA Method 29 has always included the analysis of the impinger contents for all of the metals. For
several of the metals such as selenium and arsenic there are specific reagents in the impingers which are
designed to collect the metals that pass through the filter. Since digestion and analyses would be
required for the filterable component and digestion of the impinger contents is required for those metals
with special reagents, the additional cost is due to the analysis by the ICP instrument. Since this
instrument analyzes all metals concurrently, there would be no or little reduction in the analysis cost for
the impinger contents. In addition, for a few of the Method 29 tests conducted for the Phase III portion
of the ICR, substantial percentages of the metals were in the impinger analysis. Eliminating the results
of the impinger contents would introduce a significant negative bias into the results.

Commenter 15: Commenter 18502 discusses the increased cost for non-continental EGUs of emissions
testing to document compliance with the proposed limits. The commenter explains that as a non-
continental unit, they contract with emissions testing firms located in the continental U.S. and have
higher costs per test despite having smaller units than is common in the continental U.S. The commenter
also cites the requirement to test for individual metals rather than filterable PM as a cause of increased
cost of compliance testing per megawatt of capacity to be significantly higher than for continental EGUs
with little environmental benefit associated with frequent emissions testing.

Response to Comment 15: The EPA generally agrees with the commenter and has modified the testing
requirements and monitoring options of this rule in an effort to decrease costs to affected units.

Comment 16: Commenter 17758 states that DSI will be a useful and cost-effective control tool for
many units, but it is not a viable option for all coal-based units for compliance with the acid gas
standard. In many circumstances, the EPA's analysis of DSI significantly underestimates the time
needed for, as well as the cost of, compliance in many circumstances. First, DSI could have limited
application as a compliance option due to operational impacts and cost considerations that the EPA has
not taken into consideration. Second, the use of DSI could impact beneficial use of fly ash, resulting in
increased disposal volumes, costs and loss of revenue. Third, DSI is not a viable option for eastern
bituminous coals, which require the use of wet FGD; compared to DSI, wet FGD is more costly and
takes more time to implement, leading to timing concerns for compliance. Many companies will need
more than the 3 years and will spend more than the EPA estimates to achieve compliance.

Response to Comment 16: The EPA also believes that DSI has the potential to be a useful and cost-
effective control technology option for many units. We also agree that it is not an appropriate option for
many facilities. Overall the EPA believes that the technology is most applicable for units burning lower-
sulfur content coal (including, potentially, low-sulfur bituminous coal). The EPA has considered
operational impacts and cost considerations. In some cases the EPA has assumed that a "polishing"
fabric filter will be installed downstream of the primary control device. This configuration (similar to the
TOXECON(tm) configuration for Hg control) allows dry sorbent to be injected after the primary PM
control device, thus keeping the ash and dry sorbent (both alkaline sorbent for acid gas control and
activated carbon sorbent for Hg control) separate. This will help to preserve the salability of the fly ash
and may reduce the costs of disposal if the ash and spent sorbents can be disposed of separately.
However, the EPA did include an analysis evaluating the impact of increased disposal costs for ash
residuals that contain sodium containing sorbents (such as Trona or sodium carbonate). The EPA's

543


-------
analysis of the final rule includes an IPM sensitivity case using a DSI waste disposal cost of $100/ton.
The sensitivity case indicates that a 100% increase in assumed DSI waste disposal cost produces slightly
less than a 1% increase in the projected cost of the rule. Regarding the compliance time - this is
addressed elsewhere in response to comments.

Comment 17: Commenter 17681 questions whether the EPA factored in the cost of additional catwalks
required due to the additional CMS and/or sorbent trap system equipment. According to the commenter
some facilities cannot place additional CMS ports where the current catwalk is located due to a lack of
physical space on the stack surface area at the elevation and such additional equipment may require
additional catwalk levels. Commenter notes that the Lakeland coal unit does not appear to have
sufficient room on its current elevation where the monitors are located at this time for an additional
monitor without bringing the integrity of the stack into question (if additional stack ports must to be
carved out). Lakeland's Unit 3 coal unit already has existing monitor equipment and the addition of a
PM CEMS and/or Hg monitor/sorbent may require the installation of an additional catwalk.

Response to Comment 17: The Agency's analysis represents the average cost of purchasing, installing,
operating, and maintaining emissions control equipment. Application of emissions control equipment at
an individual site with unique circumstances may cost more or less than the average, depending on
factors such as the owner or operator's ability to engineer effective approaches that ensure compliance
with the rule's emissions limits.

Commenter 18: Commenter 16849 states that the EPA makes the assumption most units currently
monitor moisture content. The commenter does not measure moisture content continuously and it is their
understanding that the majority of units do not monitor moisture content. The commenter asserts that the
EPA needs to remove this assumption from floor and cost calculations.

Response to Comment 18: The Agency finds the commenter's concern unfounded. No assumption
regarding continuous moisture content monitoring has been made for this rule, even though the Agency
is aware that owners or operators of many EGUs subject to the acid rain program choose to monitor
stack moisture on a continuous basis.

544


-------
6H - Impacts/Costs: Projection of New Units
Comments are addressed in Section 4 of this document.

545


-------
61 - Impacts/Costs: Economic Impacts/Employment Impacts

Commenters: 12050, 15002, 16469, 16549, 16705, 16849, 16856, 16858, 16859, 17004, 17022, 17026,
17028, 17123, 17137, 17254, 17265, 17386, 17400, 17403, 17409, 17620, 17623, 17627, 17629, 17638,
17639, 17640, 17648, 17654, 17656, 17676, 17681, 17682, 17689, 17690, 17692, 17697, 17698, 17701,
17702, 17705, 17707, 17710, 17711, 17712, 17716, 17718, 17725, 17730, 17731, 17732, 17736, 17743,
17745, 17751, 17756, 17761, 17765, 17767, 17771, 17772, 17774, 17775, 17791, 17797, 17799, 17800,
17805, 17806, 17807, 17808, 17811, 17812, 17813, 17815, 17817, 17821, 17824, 17829, 17834, 17839,
17840, 17842, 17844, 17853, 17854, 17855, 17867, 17868, 17875, 17877, 17879, 17880, 17881, 17884,
17886, 17887, 17901, 17903, 17904, 17909, 17911, 17917, 17919, 17921, 17930, 17931, 18014, 18016,
18017, 18018, 18021, 18025, 18026, 18030, 18033, 18038, 18039, 18419, 18421, 18422, 18422, 18424,
18425, 18428, 18430, 18432, 18433, 18433, 18433, 18435, 18436, 18437, 18441, 18447, 18477, 18478,
18480, 18481, 18484, 18486, 18488, 18489, 18497, 18498, 18500, 18502, 18538, 18540, 18575, 18907,
18933, 18961, 19041, 19042, 19114, 19121, 19199, 19211, 19212, 19213, 19214, 19580, 19653, 19536,
19537, 19538, 19742, 18023

1. Job losses and economic impact/cost.

Comment 1: Multiple commenters (16549, 17137, 17656, 17736, 17840, 17887, 17901, 17931, 18488,
18023, 19742) believe the proposed rule will weaken industry, cause job losses and hurt power
consumers. Commenter 16549 reports that the proposed rule will affect 1,350 coal- and oil-fired units at
525 power plants and that NERC reports that by 2018 nearly 50,000 MW of capacity will be retired by
the proposed rule. This commenters compare the various cost estimates released in addition to the $10.9
billion cost estimated by the EPA. The EIA report of $358 billion and a Representative Upton and
Senator Inholfe estimate of $300 billion by 2015 show that some believe the EPA's cost estimates to be
very low. The commenters express concern for the electricity price increases that are likely to be up to
24% in some regions as a result of the proposed rule. In addition to the economic difficulty the proposed
rule could place on consumers, the commenters believe that many in the energy sector will lose their
jobs due to coal-fired capacity losses. The commenters believe coal-fired plants in the southeast
especially will mean the loss of high-paying, high-skilled jobs and drastic price increases in energy
costs.

Response to Comment 1: The agency has estimated the annual costs of the rule in 2015 to be $9.6
billion in 2007 dollars. The estimate of early retirements of coal-fired units is 4.7 Gigawatts. Both of
these estimates were prepared using the IPM, a model that has been extensively reviewed and has been
utilized in several rulemakings affecting the power generation sector over the last 15 years. The
agency's analyses are credible and accurate to the extent possible. Limitations and caveats to these
analyses can be found in the RIA for the rule. Retail electricity price impacts are estimated to increase
by 3.1% in 2015.. The agency also found that the impact on employment nationally should be small on
net, with about 46,000 job-years of one-time construction labor supported or created by this rule, and a
loss of 15,000 to an increase of 30,000 jobs expected on an annual basis. The agency has used peer-
reviewed studies in the preparation of the employment impact analyses. In addition, commenters are not
comparing apples to apples. EIA has at no time provided an analysis of the costs of MATS as proposed
or finalized, and other studies showing large negative impacts have many flaws. The primary
weaknesses with these studies are the poor reflection of the actual rule requirements, inadequate
inclusion of proven technologies, and speculation with regards to other policy, like climate policy.

Comment 2: Several commenters (16705, 17403, 17123, 17400, 17771, 17817, 17829, 17909, 18437,
18575) express concern that the proposed rule, if finalized in its current form, will significantly impact

546


-------
jobs and electricity rates, leading to closed businesses. Commenter 17123 also calls for a practical,
affordable, achievable energy solution. Commenter 17771 expresses concern specifically about the
burden of the proposed rule on New Mexico. Commenter 17909 believes the leveling of the national
electricity price and modernization of the fleet is outside the scope of the EPA's regulatory authority.
Commenter 18575 expresses concern for the impacts likely in South Dakota, Minnesota and Iowa.

Response to Comment 2: The agency has estimated that there could be employment impacts on the
power sector of up to 46,000 job-years of construction labor supported or created from new pollution
control equipment installed, and a range of annual employment impacts of a loss of 15,000 jobs to a gain
of 30,000 jobs. Although the agency does not claim what the total employment impact will be of this
rule, it is important to note that there will be some positive gains in certain sectors, and overall the
impact is likely to be small. The EPA estimates that there will be an increase of 3.1% in retail electricity
price on average nationwide in 2015 as an outcome of this rule, with the range of increases from 1.3 to
6.3% in regions throughout the U.S. These results are found in the RIA for the rule. The agency also
examined the impact of the increases in electricity prices to industries outside of the electric power
sector and found that changes in product price and output should be less than 1 % in 2015 for the many
industries (100) included in the analysis. There may be impacts on a firm-level that could be higher than
this, but these analysis results suggest that the economic impacts on average nationally should be
modest.

Comment 3: Commenter 19212 urges the EPA to give state regulators the flexibility in implementation
to allow consumer protection against massive utility rate increases.

Response to Comment 3: Utilities have discretion in how to meet the requirements of this rule, and
EPA analysis indicates that the impact to electricity consumers will be reasonable given the large
benefits,

Comment 4: Several commenters (16858, 17022, 17028) express concern that a 10 to 20% increase in
electricity costs can lead to profit loss and job loss. The commenters believe that the most effective way
to protect the environment is to ensure economic prosperity so that resources are available for
improvements.

Comment 5: Several commenter (17004, 17022, 17026, 17028) report being advised by their utility
provider that the proposed regulation could result in double-digit price increases for power.

Response to Comments 4-5: The agency's analysis in the RIA for the rule finds that retail electricity
prices will increase by 1.3 to 6.3% in 2015. No region of the U.S. is expected to experience a double-
digit increase in retail electricity prices in 2015 or in any year later than that, according to the agency's
analysis. In addition, the agency finds that sectors experiencing these electricity price increases will not
experience increases in prices or decreases in output of more than 1 %. The agency believes the
economic impact of this rule is modest in light of the benefits that will accrue to those who will now
experience less pollution of HAP and other pollutants than previously.

Comment 6: Commenter 17842 questions the lack of consideration of the cumulative effects of
interrelated rules, which may collectively lead to more retirements. The commenter states that local
utilities have reported temporary job gains due to the replacement of retired generation, but a net
decrease in full-time work. The commenter asks the EPA to reassess the costs and impacts of the
proposed rule.

547


-------
Commenter 18424 states that the EPA's conclusion that bituminous coal production will increase as a
result of Utility MACT is based on two flawed assumptions. First, as discussed above, the EPA assesses
the impacts of the Utility MACT as if it were the only regulatory driver affecting a company's
compliance and economic decisions. The EPA analysis ignores the cumulative impact of all the new
CAA regulatory requirements a utility will have to consider when it determines its compliance strategy.
As a result of ignoring the cumulative impacts on decision making by utilities, the EPA projects
approximately 10 GW of coal units will be retired because of Utility MACT. In contrast, the NERA
analysis, which considers the impacts of both Utility MACT and CSAPR together, projects nearly 48
GW of coal unit retirements - most of which are smaller and older units burning bituminous coal. Other
studies predict similar levels of coal unit retirements. This degree of retirements would have a
devastating impact on Indiana's coal industry and consumers of electricity.

Response to Comment 6: The final CSAPR was included in the baseline analysis for MATS. The
agency did not prepare a cumulative impact analysis to accompany the rule for the following reasons: 1)
the various EO requirements that the agency must comply with require us to estimate impacts specific to
this rule; 2) decision makers and the public need to know the impacts specific to a particular rule in
order to judge the merits of the regulation; 3) estimates specific to a particular rule are more transparent
than those from a cumulative impact analysis. A cumulative impact analysis lumps several regulations
together and can potentially mask a high-cost/low-benefit regulation among other rules that may have
large net benefits. By analyzing each regulation separately, the EPA makes clear statements about what
impacts, costs, and benefits will be generated as a result of this particular regulation. The EPA analysis
also indicates that there will be relatively modest amounts of retirements and installation of pollution
controls will be a cost-effective compliance measure. In addition, many coal facilities have already
invested in pollution controls, and they are well positioned to comply with this rule with modest changes
to operations. In addition, the EPA has conducted an updated employment analysis which shows some
potential positive and negative employment changes from the rule, but overall expects the employment
impact to be relatively small in comparison to the affected sector and the overall economy.

Comment 7: Commenter 17824 reports that the majority of coal-fired units that do not have scrubbers
are small units that may find the cost of upgrades too expensive and will shut down instead, leading to
job loss and decreased local revenue.

Response to Comment 7: The requirements of the rule do not mandate a particular technology, and
there are other options available to utilities that will assist with compliance. In addition, the EPA has
included in its analyses various cost functions for pollution controls that reflect differences in cost across
unit sizes, and the projected impacts reflect these effects.

Comment 8: Commenter 17639 encourages the Federal Government to implement cost benefit and job
impact analyses before enactment of all rules and regulations. This commenter also states that the
proposed rule compliance costs would make it challenging for older coal-fired units to comply and lead
to retirement and energy cost increases of 17.6% in 2016. These increases would disproportionately
affect economically vulnerable families.

Comment 9: Commenter 18502 believes there is a disjunction between the President's public policies
and the proposed rules as they relate to job creation, public burden, and economic development. The
commenter cites EO 13563, EO 13132, EO 12866, and EO 13211 as the Executive Orders of concern.

Response to Comments 8-9: The agency followed all requirements under Executive Orders 12866,
13563, 13132, 13175, 13045, 13211, 12898, and the Unfunded Mandates Reform Act in preparing this

548


-------
proposed rule. The analyses completed in adherence to these requirements can be found in the RIA and
in various TSDs in the public docket for this rulemaking. The agency estimates a nationwide retail
electricity price increase of 3.1% in 2015 in response to this rule. The agency is mindful of the potential
impacts of retail electricity price increase in response to the rule, but state and local agencies are best
equipped to develop rate structures that may mitigate these price increases. In addition, the EPA has
conducted an updated employment analysis which shows some potential positive and negative
employment changes from the rule, but overall expects the employment impact to be relatively small in
comparison to the affected sector and the overall economy. This is also consistent with the economic
literature on this subject.

Comment 10: Commenters 17656 and 18023 quote an IHS/Global Insight estimate that every $1 billion
spent on upgrades to comply with the proposed rule will put 16,000 jobs at risk and reduce gross
domestic product (GDP) by as much as $1.2 billion.

Response to Comment 10: The agency's modeling of impacts for this rule is concentrated on effects to
the electric power sector. Our analysis of employment impacts finds a short-term impact of 46,000 job-
years supported or created, with a longer-term impact of between a loss of 15,000 jobs and a gain of
30,000 jobs annually. We do not include impacts of employment beyond the regulated sector. We do not
provide an estimate of a change in GDP. The EPA has conducted an updated employment analysis
which shows some potential positive and negative employment changes from the rule, but overall
expects the employment impact to be relatively small in comparison to the affected sector and the
overall economy. This is also consistent with the economic literature.

Comment 11: Commenter 17840 considers the proposed rule to discourage technology improvements,
raise electricity costs and harm the economic well-being of the country, so the EPA needs to rescind the
proposed rule.

Response to Comment 11: The EPA has designed a rule that is intended to offer flexibility, to the
extent possible, while ensuring public health is protected in accordance with requirements outlined in
the CAA. History has shown that industry adapts to regulations and finds more cost-effective
compliance approaches that the EPA can anticipate or predict, thus lowering the actual cost of its rule
relative to what the EPA initially projected. The EPA has conducted detailed economic impacts analysis
on the regulated sector, and finds the impact of the rule on the regulated sector is small compared to the
overall benefits, and the industry has an excellent track record of installing pollution controls without
greatly impacting electricity prices.

Comment 12: Commenter 17839 questions the concerns expressed about increased costs for electricity
consumers. The commenter states that public utility commissions in each state will determine a fair and
reasonable rate structure. The commenter states that any increased cost to the utility caused by the
proposed rule will be amortized as a capital expenditure over a number of years, reducing the rate
impact. The commenter calls on utilities to substantiate their claims of increased costs and points out
that it is not the EPA's responsibility to factor rate increases into the adoption of the proposed rule.

Response to Comment 12: The EPA will work with relevant authorities to ensure a smooth transition
with this rule. Public utility commissions and other regulatory authorities have extensive experience
with regulatory requirements and treatment of costs to consumers, and are prepared for responding to the
cost of future pollution control equipment or other response measures. In addition, there are certain
provisions for granting utilities some additional time to comply, if conditions warrant (see preamble).

549


-------
Comment 13: Commenter 17716 rejects the EPA's view that the proposed rule will encourage energy
efficiency savings to offset higher electricity costs. The commenter points out that table 23 of 76 FR
25074 does not support this claim and shows only a slight reduction in compliance costs from 2015 to
2030.

Response to Comment 13: The EPA believes energy efficiency measures can be a complement to this
rule, and can be an important tool in helping address emissions. The EPA has not included all the likely
additional energy efficiency measures that are likely to occur by 2015, but will continue to pursue
energy efficiency improvements throughout the economy, along with other federal agencies, states and
other groups. This will contribute to additional environmental and public health improvements while
lowering the costs of realizing those improvements. A reduction in compliance costs with the rule does
take place over time, and so does a reduction in retail electricity price increases across the U.S. as seen
in the RIA for the rule. Thus, while this reduction in impacts is modest, it does suggest that energy
efficiency increases may somewhat mitigate the impacts of the rule.

Comment 14: Commenter 17868 refers to the American Coalition for Clean Coal Electricity
(www.cleancoalusa.org) projecting net nationwide employment losses totaling 1.44 million job years by
2020 as a result of the proposed rule.

Response to Comment 14: The estimate of employment losses supplied by the commenter reflects a
cumulative estimate of employment losses over the time period of 2012 to 2020 related to
implementation of both the CSAPR and the MATS proposal, and has many weaknesses. Thus, this
estimate is not for the proposed rule alone, and is not a transparent analysis whose assumptions and
inputs can be verified. In addition, the report upon which this estimate is based (NERA report,
September 2011) does not show what type of employment impacts are assessed (construction, operation,
etc.). The Agency's estimates both short-term and long-term employment impacts specific to this rule,
which can be found in the RIA for the rule. The updated employment analysis for the final rule shows
some potential positive and negative employment changes from the rule, but overall expects the
employment impact to be relatively small in comparison to the affected sector and the overall economy.
This is also consistent with the economic literature.

Comment 15: Commenter 19042 presents the results of an analysis by the EOP Foundation on the
proposed rule. The commenter estimates that the proposed rule will increase federal outlays by $286
million annually due to electricity purchases and costs absorbed by federal agencies for boiler
modifications. The analysis shows increased annual federal agency costs from $1 million to $17 million
annually per region, or an increase of 1 to 5%.

Response to Comment 15: The agency has considered this data as part of its UMRA analysis for the
final rule.

Comment 16: Commenter 18023 estimates that capital spending and fuel switching required for
compliance with the proposed rule could increase electricity prices by 10 to 20% over the next 10 years
in the south. The commenter also cites a NERA analysis showing a 10 to 25% increase in the same
timeframe, with job losses of 250,000-500,000. These losses could result in financial difficulty for local
governments dependent on tax revenues that have a short time period in which to implement budget
cuts. The commenter estimates that there are 6 to 10 jobs at a coal-fired EGU for every job at a
comparably sized NGCC EGU, and the jobs lost to coal-fired EGU closures are among the higher
quality jobs. Also, jobs associated with mining and transportation of coal will be lost, creating a net loss
of jobs for decades.

550


-------
Response to Comment 16: The agency's analysis of impacts on retail electricity prices resulting from
this rule shows that there is an average increase nationwide of 3.1% in 2015, with a range of increases
from 1.3 to 6.3% in that same year. The employment impacts estimated by the agency include a short-
term increase of 46,000 job-years of construction labor, and a range of impacts on long-term labor from
a loss of 15,000 to an increase of 30,000 jobs annually nationwide. We disagree that the rule will cause
the size of impacts that are presented in the NERA analysis, which actually estimates the impacts from
four EPA power plant rules - not just from MATS, and has many flaws. The EPA has conducted detailed
economic impacts analysis on the regulated sector, and finds the impact of the rule on the regulated
sector is small compared to the overall benefits, and the industry has an excellent track record of
installing pollution controls without greatly impacting electricity prices. In addition, the EPA has
conducted an updated employment analysis which shows some potential positive and negative
employment changes from the rule, but overall expects the employment impact to be relatively small in
comparison to the affected sector and the overall economy. This is also consistent with the economic
literature.

Comment 17: Commenter 17761 expresses concern about the potential impacts on electricity rates and
grid reliability problems created by the proposed rule and the cost of replacement generation
alternatives. (The commenter shares the following link to the organizations resolutions concerning the
proposed rule: See Resolutions ERE-5 and EL-3 at:
http://summer.narucmeetings.org/2011 SummerFinalResolutions.pdf and

http://www.namc.org/Resolutions/Resolution%20on%20the%20Role%20of%20State%20Regulatorv%2
0Policies%20in%20Development%20of%20Fed%20Enviro%20Regs.pdf.)

Comment 18: Commenter 17877 urges the agency to include in its consideration the negative impacts
of increased electric power costs as it finalizes the rule and believes that significant changes should be
made to the proposed standards.

Comment 19: Many commenters (17829, 17830, 17831, 17889, 17892, 18480, 18481, 18924, 19564,
19565, 19574, 19581, 19601) express concerns about the negative impacts that the proposed rule could
have on the economy and ask that the EPA reconsider the rule.

Response to Comments 17 -19: The EPA has designed a rule that is intended to offer flexibility, to the
extent possible, while ensuring public health is protected in accordance with requirements outlined in
the CAA. History has shown that industry adapts to regulations and finds more cost-effective
compliance approaches that the EPA can anticipate or predict, thus lowering the actual cost of its rule
relative to what the EPA initially projected. The EPA has conducted detailed economic impacts analysis
on the regulated sector, and finds the impact of the rule on the regulated sector is small compared to the
overall benefits, and the industry has an excellent track record of installing pollution controls without
greatly impacting electricity prices.

Comment 20: Commenter 17919 discusses the impact on the Federal Budget Deficit. The commenter
explains that the federal government is a major consumer of electricity, and the proposed rule is
estimated to increase the federal outlays for electricity by a minimum of $286 million annually, plus
embedded energy costs associated with good and services. States and municipalities will be likewise
impacted.

Response to Comment 20: The UMRA analysis done by the agency covers impacts to states and
municipalities and shows the results in aggregate in the RIA for the rule. We have considered the federal

551


-------
impacts presented by the commenter in the analyses for the final rule as well and found them to be
reasonable in light of the expected benefits of the rule.

Comment 21: Multiple commenters (12050, 17844, 17854, 17875, 17880, 18025, 18421) support the
EPA's impact analysis and dispute claims by other commenters that the projected rule will harm
economic growth. Several commenters (12050, 17875, 18421) mention testimonials by power company
CEOs stating that the proposed rule will not affect the economic health of the industry and a survey
showing nearly 60% of the coal-fired units already comply with the EPA's proposed Hg standard, as
well as several other meaningful quotes from utility executives. Commenters also point out that 17 states
already require plants to address Hg pollution, with some imposing more stringent emission limits than
the EPA proposes. Commenters believe that utilities use the threat of power plant closures and lost jobs
to delay Hg reductions from coal-fired plants. Commenters 17875 and 18421 also believe that the rules
will drive innovation and job creation as new technologies to reduce pollution are created. These
commenters, along with commenter 18478, quote the Economic Policy Institute finding that the
proposed rule will increase job growth by 28,000 to 158,000 jobs by 2015 (including approximately
56,000 direct jobs and 35,000 indirect jobs), the University of Massachusetts study that showed an
increase in 1.4 million jobs in 5 years, and the Constellation Energy Group installation project that
employed nearly 1,400 skilled workers. Commenters 17844 and 17854 also cite the University of
Massachusetts study statement that a net gain of over 4200 long-term operation and maintenance jobs
will result.

Response to Comment 21: The agency thanks the commenters for their comments. The agency's
estimates of employment impacts, which are found in the RIA for the rule, are smaller than the
commenters' though we use a different methodology that focuses on impacts to the electric power
sector. The EPA has conducted an updated employment analysis which shows some potential positive
and negative employment changes from the rule, but overall expects the employment impact to be
relatively small in comparison to the affected sector and the overall economy.

Comment 22: Several commenters (17265, 17638, 17681, 18023) express concern about the impact of
the proposed rule on electricity rates and Florida's economy and job loss. Commenters believe the EPA
has underestimated the impact. Commenter 17265 reminds the EPA of the Presidential Order 13563
which calls for the EPA to exercise its authority to minimize burden, explore all other options and
include discussion in the preamble of measures evaluated. Commenters 17681 and 18023 point out that
by 2015 these impacts will disproportionately affect the elderly, minorities, and low income populations,
resulting in:

1.	Average electricity rate increase of nearly 25%

2.	Gross State Product loss of nearly $18 billion (nearly 2.5%)

3.	Annual job losses of 157,000

4.	Unemployment rate of nearly 13%

5.	Lost annual manufacturing output of $1.3 billion

6.	Lost annual state and local government tax revenues of $2.1 billion

7.	Additional costs for control and monitoring equipment, upgrading transmission capabilities and
impacts to municipal generating utilities.

Response to Comment 22: The agency has estimated economic impacts to the extent possible and as
accurately as possible. The agency is also mindful of EO 13563, and has included an extensive
discussion in the preamble of measures and options evaluated in the course of designing this rule. The
agency estimates an increase in average retail electricity price nationwide of 3.1 % in 2015. The agency

552


-------
also estimates employment impacts of an increase nationally of 46,000 job-years due to construction of
new pollution control equipment, and a range of a loss of 15,000 jobs to a gain of 30,000 jobs nationally
for operating this equipment. We do not include employment estimates specific to individual states due
to a lack of specific information to provide credible estimates. The EPA has conducted an updated
employment analysis which shows some potential positive and negative employment changes from the
rule, but overall expects the employment impact to be relatively small in comparison to the affected
sector and the overall economy.

Comment 23: Commenter 19580 believes that if the EPA finalizes this rule it is only a matter of time
before our strong manufacturing base moves overseas, taking high wage jobs. The commenter sees the
proposed rule as an excessive regulation that will cost billions of dollars, lead to higher electricity prices
and job losses as well as compromising reliability.

Response to Comment 23: The EPA has designed a rule that is intended to offer flexibility, to the extent
possible, while ensuring public health is protected in accordance with requirements outlined in the CAA.
History has shown that industry adapts to regulations and finds more cost-effective compliance
approaches that the EPA can anticipate or predict, thus lowering the actual cost of its rule relative to what
the EPA initially projected. The EPA has conducted detailed economic impacts analysis on the regulated
sector, and finds the impact of the rule on the regulated sector is small compared to the overall benefits,
and the industry has an excellent track record of installing pollution controls without greatly impacting
electricity prices. Based on the information provided in the RIA and supporting materials, the EPA does
not agree that the impacts of this rule will transfer significant industrial production overseas.

Comment 24: Several commenters (19536, 19537, 19538) state that the EPA is obligated to impose
lower HC1 emission limits because the cost-benefit analysis did not quantify the improved reductions of
other acid gases such as HF that should be achieved with HC1 controls, and the EPA's cost-benefit
analysis likely underestimates true benefits of a 0.0001 lb/MMBtu HC1 limit. Also, commenters point out
that the EPA analysis does not take into account the SO2 controls required to meet other rules, so the
costs are likely to be overstated.

Response to Comment 24: The agency has quantified the reductions in HF emissions as part of its
analysis of the impacts of setting HAP emissions limits as part of the rule. We are unable to monetize the
benefits of such emissions; this is also true of other acid gas HAP reductions that could occur as a result
of this rule. Finally, the agency has included SO2 controls in existence or planned that it is aware of for
sources to be subject to this rule in the baseline for the analysis presented in the RIA.

Comment 25: Commenter 17648 believes the proposed rule will promote long-term economic health by
encouraging investment in modern, efficient EGUs. The commenter cites upgrades to existing nuclear
plants to improve zero-pollution nuclear generation by several gigawatts, investments in alternative,
renewable technologies, co-generation, improved energy-efficient combined cycle gas-fired plants,
modern coal-fired plants, coal gasification combined cycle plants and technology to recover domestic
shale gas resources as potential opportunities.

Response to Comment 25: We thank the commenter for their comments and the data they have
provided. The agency's employment impact analysis does not include estimation of impacts using this
BLS data, but we think our analysis of employment was appropriate given our approach and the data
available to the agency for the proposal. Investment in more modern power generation capacity and
pollution control technology is a likely outcome of this rule. The agency does believe that retail

553


-------
electricity prices nationwide will be higher in 2015 as a result of the rule, though that increase is modest
(3.1% on average in 2015, with a range of regional impacts from 1.3 to 6.3%).

Comment 26: Commenter 18419 cites the Edison Electric Institute study of impacts from the proposed
rule and found that 50% of the U.S. coal fleet may be unavailable by 2015 due to insufficient time to
acquire controls or find replacement generation. In addition, the commenter notes that the study shows
that utility providers will spend up to $20 billion in the next 50 years disposing of coal ash, and the
proposed ozone limits are also a concern if lowered to 0.060 ppm because 13 of 14 monitored counties
in Alabama will become non-attainment areas. According to the commenter, nationwide, 85% of
monitored counties will become non-attainment for ozone and the cost for coming into attainment will
be $20-$90 billion annually.

Comment 27: Comment 18488 cites the ICF report that concludes the proposed rule will impose
incremental capital costs on industry of $141-247 billion and will lead to significantly more retirements
than the EPA predicts, leading to reliability issues and increases in costs.

Response to Comments 26-27: The EPA has designed a rule that is intended to offer flexibility, to the
extent possible, while ensuring public health is protected in accordance with requirements outlined in
the CAA. History has shown that industry adapts to regulations and finds more cost-effective
compliance approaches that the EPA can anticipate or predict, thus lowering the actual cost of its rule
relative to what the EPA initially projected. The EPA has conducted detailed economic impacts analysis
on the regulated sector, and finds the impact of the rule on the regulated sector is small compared to the
overall benefits, and the industry has an excellent track record of installing pollution controls without
greatly impacting electricity prices. In addition, the EPA has analyzed resource adequacy issues and
finds that there is ample existing spare capacity to serve load, and industry has also shown that it can
build new capacity quickly in response to demand. Studies done by industry have several flaws,
including a poor reflection of the actual rule requirements, inadequate inclusion of proven technologies,
and unsupported speculation with regard to other policy, like climate policy. Changes to the national
ambient air quality standards for ozone are not a subject of this rulemaking.

Comment 28: Commenter 18023 states that the estimated costs do not include billions of lost economic
productivity that may be incurred due to load shedding to manage the bulk power system.

Response to Comment 28: The EPA has designed a rule that is intended to offer flexibility, to the
extent possible, while ensuring public health is protected in accordance with requirements outlined in
the CAA. History has shown that industry adapts to regulations and finds more cost-effective
compliance approaches that the EPA can anticipate or predict, thus lowering the actual cost of its rule
relative to what the EPA initially projected. The EPA has conducted detailed economic impacts analysis
on the regulated sector, and finds the impact of the rule on the regulated sector is small compared to the
overall benefits, and the industry has an excellent track record of installing pollution controls without
greatly impacting electricity prices.In addition, the EPA has analyzed resource adequacy issues and
finds that there is ample existing spare capacity to serve load, and industry has also shown that it can
build new capacity quickly in response to demand.

Comment 29: Commenter 17682 requests the EPA consider the added cost impacts for generation of
electricity from coal, the cumulative impacts of new wind turbines and solar panels and new electrical
distribution lines.

554


-------
Response to Comment 29: The EPA has conducted detailed impact analysis of the rule, which shows
reasonable impacts to retail electricity prices. The analysis includes the specific operating parameters
and variability of other technologies, like wind and solar, and does not show that the rule will lead to
extensive substitution away from coal-fired generation. Industry has shown that it can install large
amounts of pollution controls and often finds more cost-effective compliance options than the EPA can
anticipate. In addition, the EPA has analyzed resource adequacy issues and finds that there is ample
existing spare capacity to serve load, and industry has also shown that it can build new capacity quickly
in response to demand.

Comment 30: Commenters 17702 and 18033 quote the proposed rule estimate of a 3.7% price increase
for electricity in 2015, 2.6% in 2020 and 1.9% in 2030. Commenter 17702 believes this increase will
impact areas with dependence on coal and oil generation more than other regions, and the prices there
will increase more. The commenter encourages the EPA to work with state and federal energy and
environmental regulators to craft solutions that will enable utilities to comply with the proposed rule and
other EPA rules to minimize cost impacts to consumers.

Response to Comment 30: The EPA has conducted detailed impact analysis of the rule, which shows
reasonable impacts to retail electricity prices. Industry has shown that it can install large amounts of
pollution controls and often finds more cost-effective compliance options than the EPA can anticipate.
In addition, the EPA has analyzed resource adequacy issues and finds that there is ample existing spare
capacity to serve load, and industry has also shown that it can build new capacity quickly in response to
demand. The EPA will work with relevant authorities to ensure a smooth transition with this rule. Public
utility commissions and other regulatory authorities have extensive experience with regulatory
requirements and treatment of costs to consumers, and are prepared for responding to the cost of future
pollution control equipment or other response measures. In addition, there are certain provisions for
granting utilities some additional time to comply, if conditions warrant (see preamble).

Comment 31: Commenter 18033 considers the low estimate of early retirements to be one reason the
EPA's impacts are so much lower than other estimates. The commenter explains that the biases within
the EPA's model are incorrect because the model assumes that regions with excess supply will absorb
the capacity lost by retirements, making retirement decisions a product of geography rather than
economic factors.

Response to Comment 31: The EPA has conducted detailed updated economic analysis of the rule, and
believes that the impact on potential retirements to be driven by both economic and geographic
(locational) considerations, which the EPA modeling fully reflects. In addition, the EPA has analyzed
resource adequacy issues and finds that there is ample existing spare capacity to serve load, and industry
has also shown that it can build new capacity quickly in response to demand. The EPA will work with
relevant authorities to ensure a smooth transition with this rule. Public utility commissions and other
regulatory authorities have extensive experience with regulatory requirements and treatment of costs to
consumers, and are prepared for responding to the cost of future pollution control equipment or other
response measures. In addition, there are certain provisions for granting utilities some additional time to
comply, if conditions warrant (see preamble).

Comment 32: Commenter 18961 cites a study done by a consortium of electric companies that found,
"Industry data counter concerns that it will cost the industry too much to comply with EPA's proposed
air regulations, that pollution controls cannot be installed soon enough, or that the EPA regulations will
lead to the closure of otherwise economically healthy power plants." The commenter reports that the
study also notes that the proven technologies for controlling Hg and other air toxics are commercially

555


-------
available, and adds that the coal-fired units that are most likely to be retired in the face of the new rule
are smaller, 40- to-60-year old units that are already "economically challenged" and nearing the end of
their design life expectancies. (Ensuring a Clean, Modern Electric Generating Fleet while Maintaining
Electric System Reliability, M.J. Bradley & Associates LLC and Analysis Group. August 2010.
http://www.mibradlev.com/documents/MJBAandAnalvsisGroupReliabilitvReportAugust2010.pdf)

Response to Comment 32: The EPA agrees with the commenter. The EPA has conducted detailed
updated economic analysis of the rule, and believes that the impacts to be reasonable given the large
benefits.

Comment 33: Commenter 17761 states that the impact analysis conducted by the EPA is inaccurate and
not comprehensive and needs to be revised to account for true costs and benefits of the rule on regulated
entities and the general public.

Response to Comment 33: The EPA has conducted as detailed and comprehensive an updated
economic analysis of the rule as reasonably possible to reflect the true costs and benefits, and
commenter does not substantiate the claims made.

Comment 34: Multiple commenters (16549, 17114, 17639, 17698, 17782, 18033) ask that the EPA
delay indefinitely its proposed Utility MACT rule until further study can be undertaken on the potential
costs and negative incomes to industry, jobs, and consumers. Commenters state that the current
compliance deadline of 3 years does not meet the tests of reasonability or realism.

Response to Comment 34: The EPA does not have the flexibility to delay the rule, which is governed
by a consent decree and the requirements of the CAA. However, it has conducted detailed economic
impacts analysis on the regulated sector, and finds the impact of the rule on the regulated sector is small
compared to the overall benefits, and the industry has an excellent track record of installing pollution
controls without greatly impacting electricity prices. In addition, the EPA has conducted an updated
employment analysis which shows some potential positive and negative employment changes from the
rule, but overall expects the employment impact to be relatively small in comparison to the affected
sector and the overall economy. The EPA has provided pursuant to CAA section 112(i)(3)(A) the
maximum 3-year period for sources to come into compliance. Sources may also seek a 1-year extension
of the compliance period from their Title V permitting authority if the source needs that time to install
controls.

Comment 35: Several commenters (17811, 18436, 18478) offer support for the EPA's proposed rule,
stating that many power plants currently utilize the technology required and the EPA is providing
adequate flexibility in the requirements by allowing facility-wide averaging for all HAP emissions from
existing units in the same subcategory, effectively providing for equivalent, less costly technology in
achieving the proposed emission standards. Commenters 17811 and 18436 encourage the EPA to move
forward with implementation, as the commenters feels it would be too costly to not regulate toxic air
pollutants. The commenters provide information from the Jefferson County Health Dept. in Alabama
that estimates 15 manufacturing businesses and roughly $5 billion in economic investments were lost in
the Birmingham metro area due to non-attainment air quality status.

Response to Comment 35: We thank the commenters for these comments. The EPA notes that the rule
does not require specific technology, but that the level of performance called for by the rule is currently
being achieved by a number of sources using certain technologies. The agency will be flexible in
allowing sources to comply with this rule consistent with the requirements of the CAA.

556


-------
Comment 36: Commenter 17877 believes that finalization of the proposed rule will result in increased
costs that non-profit cooperatives will need to pass on to consumers, which will negatively impact
economic development and jobs.

Response to Comment 36: The EPA has conducted detailed impact analysis of the rule, which shows
reasonable impacts to retail electricity prices. The analysis includes the specific operating parameters
and variability of other technologies, and is unlikely to lead to extensive substitution away from coal-
fired generation. Industry has shown that it can install large amounts of pollution controls and often
finds more cost-effective compliance options than the EPA can anticipate. In addition, the EPA has
analyzed resource adequacy issues and finds that there is ample existing spare capacity to serve load,
and industry has also shown that it can build new capacity quickly in response to demand. The EPA will
work with relevant authorities to ensure a smooth transition with this rule. Public utility commissions
and other regulatory authorities have extensive experience with regulatory requirements and treatment of
costs to consumers, and are prepared for responding to the cost of future pollution control equipment or
other response measures. In addition, there are certain provisions for granting utilities some additional
time to comply, if conditions warrant (see preamble).

Comment 37: Commenter 18025 reports that their plants are among the cleanest, most environmentally
responsible coal-fired plants in the nation due to the addition of more than $1 billion in control
technologies and cleaner-burning generation. The commenter states that these installations were
successfully coordinated with unit outages and position the facilities to comply with the proposed rule in
advance of the deadlines.

Response to Comment 37: The EPA believes that coal units that have already installed pollution
controls will be well situated to comply with this rule by taking relatively modest steps to ensure
compliance. The EPA also believes that the pollution control installations can be managed by industry.
Industry has shown that it can install large amounts of pollution controls and often finds more cost-
effective compliance options than the EPA can anticipate.

Comment 38: Commenter 18033 quotes legislative intent in The House Report on Section 112 that
states: "In the determination of MACT for new and existing sources, consideration of cost should be
based on an evaluation of the cost of various control options. The Committee expects MACT to be
meaningful, so that MACT will require substantial reductions in emissions from uncontrolled levels.
However, MACT is not intended to require unsafe control measure, or to drive sources to the brink of
shutdown. " The commenter believes the EPA's proposed rule runs counter to this intent. Commenter
18500 also reminds the EPA of Congress's statement and states their belief that this is exactly what the
proposed rule, in combination with other new or pending rules, will accomplish in addition to impairing
electric reliability and increasing costs.

Response to Comment 38: The agency is not requiring the use of any unsafe control measure.

Measures that could be applied by sources to meet the rule requirements are well-demonstrated and are
already in use at a substantial number of utilities, as explained in the preamble to the rule. In addition,
the agency has estimated that less than 2% of all coal-fired generating capacity may be uneconomic to
maintain and removed form operation by 2015 in response to the rule, and this result is the product of
business decisions rather than a specific requirement of the rule. This analysis has been updated for the
final rule.

Comment 39: Commenter 18421 supports the EPA's proposed rule and explains that new standards are
always met with claims of infeasibility and impracticality. Yet, the commenter states that history shows

557


-------
the reverse to be true. The commenter outlines proven benefit-to-cost ratios of up to 23 to 1 for EPA
regulations from 2000 through 2010 and economic growth and benefits from public health. The
commenter also outlines cost-benefit ratios for regulations from 1970-1990 that show a net benefit in
present value over the period were $22 trillion and the benefits outweighed the costs by 40 to 1.

Response to Comment 39: The EPA generally agrees with commenter's stated views. Industry has
shown that it can install large amounts of pollution controls and often finds more cost-effective
compliance options than the EPA can anticipate. The rule will also result in benefits that are many times
larger than the cost of compliance.

Comment 40: Commenter 18422 believes the proposed rule will negatively affect a significant portion
of the industry and its customers since nearly half of electric generation is fueled by coal, making the
proposed rule a threat to reliability and affordability. The Commenter requests that the EPA reconsider
the regulating of acid gases as they are not required and will impose greater cost and difficulty.

Response to Comment 40: The EPA has designed a rule that is intended to offer flexibility, to the
extent possible, while ensuring public health is protected in accordance with requirements outlined in
the CAA. History has shown that industry adapts to regulations and finds more cost-effective
compliance approaches that the EPA can anticipate or predict, thus lowering the actual cost of its rule
relative to what the EPA initially projected. The EPA has conducted detailed economic impacts analysis
on the regulated sector, and finds the impact of the rule on the regulated sector is small compared to the
overall benefits, and the industry has an excellent track record of installing pollution controls without
greatly impacting electricity prices.

Comment 41: Commenter 18430 believes that job losses and cost burdens for consumers will outweigh
any benefit from the proposed rule and asks that the EPA reconsider the rule in light of the public
comment and withdraw the proposed rule until further impact studies can be done.

Response to Comment 41: The EPA does not have the flexibility to delay the rule, which is governed
by a consent decree and the requirements of the CAA. However, it has conducted detailed economic
impacts analysis on the regulated sector, and finds the impact of the rule on the regulated sector is small
compared to the overall benefits, and the industry has an excellent track record of installing pollution
controls without greatly impacting electricity prices. In addition, the EPA has conducted an updated
employment analysis which shows some potential positive and negative employment changes from the
rule, but overall expects the employment impact to be relatively small in comparison to the affected
sector and the overall economy. The EPA has provided pursuant to CAA section 112(i)(3)(A) the
maximum 3-year period for sources to come into compliance. Sources may also seek a 1-year extension
of the compliance period from their title V permitting authority if the source needs that time to install
controls.

Comment 42: Multiple commenters (17682, 17701, 17765, 17761, 17813, 18433, 17904, 17930, 18023,
18484) express concern that the rule will result in rate increases for consumers. Commenter 18023 notes
that less affordable electricity prices would have other indirect consequences, such as the loss of energy-
intensive manufacturing operations, the loss of U.S. manufacturing jobs, a decline in tax revenues, and
risk to national security if military bases and key manufacturing and production operations do not have a
steady and reliable supply of electricity. Commenter 17765 states that utilities are already requesting
residential rate increases of up to 19% (see http:/ /www.courier-journal.com/article/20110525/BUSIN
ESS/305250080/LG-E-seek-19-rateincrease) and points out that recent regulatory impact studies predict
electricity prices will rise by as much as 25% in some regions of the country (see "Proposed CATR +

558


-------
MACT," NERA Economic Consulting, Draft May 2011). Similarly, commenter 17904 cites research
conducted by Bernstein that predicts costs in both the PJM and MISO RTOs are expected to go up
significantly and remain volatile.

Commenter 18484 believes the proposed rule will cause irreparable harm to the economy and national
security due to energy cost increases negatively affecting the ability to compete in the global market and
increasing unemployment. The commenter believes increased energy costs will harm the development
of mineral resources and the mining industry, resulting in fewer projects and jobs and increasing
dependency on foreign resources. The commenter explains that coal currently provides around 50% of
electricity in the U.S. and the nation has coal reserves to continue this for hundreds of years without
even considering the massive coal reserves in Alaska. The commenter also says that coal resources have
less environmental impact in many cases that alternative energy production since coal produces 100 to
1000 watts per square meter of land, while solar produces 4 to 9 watts/square meter, wind produces 0.5
to 1.5 w/sm and biomass produces 0.5 to 0.6 w/sm. The commenter states that the EPA needs to
complete a cost-benefit analysis that reflects the cumulative impacts of using one compliance
technology to control one pollutant on the ability of other technologies to control other pollutants and
that reflects the cost for makeup energy for lost generation and the ultimate cost increases for
consumers. The commenter asks the EPA to include the cost of the hundreds of thousands of new wind
turbines, solar panels and electrical distribution lines and consider if citizens would prefer to subsidize
uneconomic energy sources, such as wind, solar and bio-fuels or not implement the proposed rule. The
commenter also explains that the proposed rule with cost the government more money for electricity as
well, resulting in less money for basic services, including other environmental programs. The
commenter requests that the EPA withdraw the proposal and develop a more balanced rule.

Response to Comment 42: The EPA has conducted detailed impact analysis of the rule, which shows
reasonable impacts to retail electricity prices. The analysis includes the specific operating parameters
and variability of other technologies, and is unlikely to lead to extensive substitution away from coal-
fired generation. Industry has shown that it can install large amounts of pollution controls and often
finds more cost-effective compliance options than the EPA can anticipate. In addition, the EPA has
analyzed resource adequacy issues and finds that there is ample existing spare capacity to serve load,
and industry has also shown that it can build new capacity quickly in response to demand. The EPA will
work with relevant authorities to ensure a smooth transition with this rule. Public utility commissions
and other regulatory authorities have extensive experience with regulatory requirements and treatment of
costs to consumers, and are prepared for responding to the cost of future pollution control equipment or
other response measures. In addition, there are certain provisions for granting utilities some additional
time to comply, if conditions warrant (see preamble).

Comment 43: Commenter 18489 believes the estimated compliance cost of $10.9 billion will impact
the economy and jeopardize the recovery our nation needs.

Response to Comment 43: As discussed elsewhere in this document, the EPA has conducted detailed
impact analysis of the rule, which does not show significant impacts to the economy, and the costs of the
rule are greatly outweighed by the benefits.

Comment 44: Commenter 18907 foresees negative effects for smaller businesses, including retail
gasoline outlets.

559


-------
Response to Comment 44: The EPA does not anticipate a notable impact on retail gasoline outlets as a
result of this rule, and its detailed economic analyses, discussed elsewhere in this document, show the
impacts to businesses and consumers to be relatively small.

2. State/regional impacts, low income.

Comment 45: Commenter 17731 expresses concern that the EPA's overview of the price increases does
not see the hardships that will be the reality of increased prices on low-income or fixed-income
households or small businesses. The commenter reports increases of $90 million in capital costs, $11.4
million in annual operating costs and $6.4 million in annual debt service costs to achieve compliance,
which will lead to a 13% increase in rates for the proposed rule, and a 41% increase for all proposed and
new regulation compliance costs. The commenter argues against the EPA's view that energy efficiencies
will offset rate increases, because low income customers will need to use less electricity due to
economic necessity. The commenter also sees large price increases for customers if units are converted
to natural gas, which is approximately 2.5 times more expensive than the coal that the commenter
currently uses to generate electricity.

Response to Comment 45: The EPA has conducted detailed impact analysis of the rule, which shows
reasonable impacts to retail electricity prices. The analysis includes the specific operating parameters
and variability of other technologies, and is unlikely to lead to extensive substitution away from coal-
fired generation. Industry has shown that it can install large amounts of pollution controls and often
finds more cost-effective compliance options than the EPA can anticipate. In addition, the EPA has
analyzed resource adequacy issues and finds that there is ample existing spare capacity to serve load,
and industry has also shown that it can build new capacity quickly in response to demand. The EPA will
work with relevant authorities to ensure a smooth transition with this rule. Public utility commissions
and other regulatory authorities have extensive experience with regulatory requirements and treatment of
costs to consumers, and are prepared for responding to the cost of future pollution control equipment or
other response measures. In addition, there are certain provisions for granting utilities some additional
time to comply, if conditions warrant (see preamble).

Comment 46: Commenter 17743 expresses particular concern over the proposed rule's impacts on the
Oklahoma economy, such as the potential increase of electricity rates and resulting economic impacts on
residents and businesses.

Response to Comment 46: The EPA has conducted detailed impact analysis of the rule, which shows
reasonable impacts to retail electricity prices. The analysis includes the specific operating parameters
and variability of other technologies, and is unlikely to lead to extensive substitution away from coal-
fired generation. Industry has shown that it can install large amounts of pollution controls and often
finds more cost-effective compliance options than the EPA can anticipate. In addition, the EPA has
analyzed resource adequacy issues and finds that there is ample existing spare capacity to serve load,
and industry has also shown that it can build new capacity quickly in response to demand. The EPA will
work with relevant authorities to ensure a smooth transition with this rule. Public utility commissions
and other regulatory authorities have extensive experience with regulatory requirements and treatment of
costs to consumers, and are prepared for responding to the cost of future pollution control equipment or
other response measures. In addition, there are certain provisions for granting utilities some additional
time to comply, if conditions warrant (see preamble).

560


-------
Comment 47: Commenter 17772 is a utility with a large percentage of coal-fired generation. As such,
the commenter's concern is the ability to meet customer's needs for electricity if the proposed rule is
finalized, since it will lead to unit closures.

Response to Comment 47: The EPA has conducted detailed impact analysis of the rule, which shows
reasonable impacts to retail electricity prices. The analysis includes the specific operating parameters
and variability of other technologies, and is unlikely to lead to extensive substitution away from coal-
fired generation. Industry has shown that it can install large amounts of pollution controls and often
finds more cost-effective compliance options than the EPA can anticipate. In addition, the EPA has
analyzed resource adequacy issues and finds that there is ample existing spare capacity to serve load,
and industry has also shown that it can build new capacity quickly in response to demand. The EPA will
work with relevant authorities to ensure a smooth transition with this rule. Public utility commissions
and other regulatory authorities have extensive experience with regulatory requirements and treatment of
costs to consumers, and are prepared for responding to the cost of future pollution control equipment or
other response measures. In addition, there are certain provisions for granting utilities some additional
time to comply, if conditions warrant (see preamble).

Comment 48: Commenter 19213 states that the proposed rule could result in the retirement of one or
more units and increased electricity rates in Illinois, driving out businesses.

Response to Comment 48: The agency has estimated that less than 2% of all coal-fired generating
capacity may be uneconomic to maintain and removed form operation by 2015 in response to the rule,
and this result is the product of business decisions rather than a specific requirement of the rule. The
EPA has conducted detailed impact analysis of the rule, which shows reasonable impacts to retail
electricity prices. The EPA will work with relevant authorities to ensure a smooth transition with this
rule. Public utility commissions and other regulatory authorities have extensive experience with
regulatory requirements and treatment of costs to consumers, and are prepared for responding to the cost
of future pollution control equipment or other response measures. In addition, there are certain
provisions for granting utilities some additional time to comply, if conditions warrant (see preamble).

Comment 49: Commenter 19214 believes the EPA should expand the quantity and quality of their
review so that accurate, realistic and broadly-accepted expectations of the cost, development timeline
and performance of emission control systems can be considered in the final rule.

Response to Comment 49: The EPA has revised the detailed impact analysis of the proposed rule for
the final rule in a number of ways, and believes that the analysis presents an accurate and comprehensive
evaluation of the rule's impacts. The analysis includes the specific operating parameters and variability
of other technologies, and is unlikely to lead to extensive substitution away from coal-fired generation.
In addition, the EPA has analyzed resource adequacy issues and finds that there is ample existing spare
capacity to serve load, and industry has also shown that it can build new capacity quickly in response to
demand. The EPA will work with relevant authorities to ensure a smooth transition with this rule. Public
utility commissions and other regulatory authorities have extensive experience with regulatory
requirements and treatment of costs to consumers, and are prepared for responding to the cost of future
pollution control equipment or other response measures. In addition, there are certain provisions for
granting utilities some additional time to comply, if conditions warrant (see preamble).

Comment 50: Commenter 17911 questions the accuracy of the RIA and states that the EPA skipped a
number of procedural steps in their effort to meet the rule deadline. The commenter questions the EPA's
estimates as a result and calls into question the EPA's estimates of the following:

561


-------
1.	Impact of Rule on the National Economy

2.	Increase in Electric Rates (commenter expects costs to increase by several percentage points)

3.	Financing costs for emission retrofits

4.	Loss of external revenue streams from sale of CCR

5.	Increased costs for disposal of CCR

6.	Loss of revenue from increased parasitic load at power plants

7.	Decrease in Disposable Income

8.	Increase in Cost of Operation for Small Political Subdivisions

The commenter requests that EPA conduct a more robust study of the economic impact of this rule.

Response to Comment 50: The EPA has analyzed many of these impacts, which can be found in the
RIA of the rule. The EPA has not analyzed the impact of other regulations, which will be conducted in
accordance with the relevant requirements for each individual rulemaking (like CCR).

Comment 51: Commenter 17774 discusses plant closures in South Carolina which are expected to
occur in response to the proposed rule. The commenter disagrees with the EPA's prediction of job gains
and believes job losses will be focused on coal-dependent regions like the southeast.

Response to Comment 51: The agency's employment impact analysis for the proposed rule shows
some increase in short-term (i.e., by 2015) employment associated with the installation and operation of
pollution control equipment. The EPA has conducted an updated employment analysis which shows
some potential positive and negative employment changes from the rule in the long-term, but overall
expects the employment impact in the short-term and long-term to be relatively small in comparison to
the affected sector and the overall economy. This is also consistent with the economic literature.

Comment 52: Commenters 18424 and 18425 believe the EPA has underestimated the impact of the
proposed rule on EGUs burning bituminous coal and will severely impact the Indiana coal industry and
Indiana jobs in general. The first commenter explains that Indiana produces bituminous coal and expects
severe job losses in coal, mining and transportation industries, which will have a multiplier effect
causing more job losses throughout the state. The commenter quotes an ICC study showing Indiana job
losses at more than 12,000 due to the loss of coal production. The commenter also notes that the cost of
compliance will increase electricity costs and erode the competitive advantage enjoyed by Indiana in
manufacturing, leading to a total loss of 50,000 jobs in the state.

Response to Comment 52: The EPA's analysis of the rule shows that it is unlikely to lead to extensive
substitution away from coal-fired generation. Industry has shown that it can install large amounts of
pollution controls and often finds more cost-effective compliance options than the EPA can anticipate.
In addition, the EPA has analyzed resource adequacy issues and finds that there is ample existing spare
capacity to serve load, and industry has also shown that it can build new capacity quickly in response to
demand. The EPA will work with relevant authorities to ensure a smooth transition with this rule. Public
utility commissions and other regulatory authorities have extensive experience with regulatory
requirements and treatment of costs to consumers, and are prepared for responding to the cost of future
pollution control equipment or other response measures. In addition, there are certain provisions for
granting utilities some additional time to comply, if conditions warrant (see preamble). The EPA has
conducted an updated employment analysis which shows some potential positive and negative
employment changes from the rule, but overall expects the employment impact to be relatively small in
comparison to the affected sector and the overall economy. This is also consistent with the economic
literature.

562


-------
Comment 53: Commenter 16849 believes the proposed rule creates undue burden due to straying from
the cohesive air quality program goals embracing multi-pollutant control strategies. The commenter also
believes that midwest states will bear a disproportionate burden for compliance due to coal-fired
generation utilization.

Response to Comment 53: The EPA analysis shows that industry can comply with the rule largely by
installing pollution controls, and coal will continue to remain an important part of the generation mix.
By addressing revisions to the NSPS and standards for emissions of mercury and other HAP, and by
accounting for the multi-pollutant co-benefits of the rules, the EPA has sought to coordinate
requirements for the control of multiple pollutants and thus is being responsive to the goal of multi-
pollutant control strategies.

Comment 54: Commenter 19041 expresses concern that the proposed rule will have effects on the
ability of their cooperative to provide affordable and reliable service to consumers in Ohio. The
commenter reports that the cooperative has already installed SCR on coal-fired units, and has or is
installing scrubbers all for around $1.8 billion but is concerned that it will not be enough to comply with
the proposed rule.

Response to Comment 54: Utilities that have already installed pollution controls are likely to be well
positioned to comply with this rule with modest modifications.

Comment 55: Commenters 19653 and 19199 state a concern that the proposed rule will have an impact
on the price of electricity in Indiana. The commenter sees the price of energy to be a major cost of doing
business, and worries that increases in energy costs will negatively impact businesses. Commenter
19653 especially expresses concern about the construction industry because the electricity cost impacts
on construction could limit availability of affordable housing in Indiana. Also, disruptions in service as a
result of the compressed timeline could delay progress on new construction and remodeling.

Response to Comment 55: The EPA has conducted detailed impact analysis of the rule, which shows
reasonable impacts to retail electricity prices. The analysis includes the specific operating parameters
and variability of other technologies and coal types, and is unlikely to lead to extensive substitution
away from coal-fired generation. Industry has shown that it can install large amounts of pollution
controls and often finds more cost-effective compliance options than the EPA can anticipate. In addition,
the EPA has analyzed resource adequacy issues and finds that there is ample existing spare capacity to
serve load, and industry has also shown that it can build new capacity quickly in response to demand.
The EPA does not anticipate large impacts on the home construction industry, and is unable to see why
the rule would impact availability of affordable housing since electricity prices are projected to increase
only modestly.

Comment 56: Commenter 17805 has concerns about the potential economic and reliability impacts of
the proposed rule on customers in Montana and the Dakotas.

Response to Comment 56: The EPA has conducted detailed impact analysis of the rule, which shows
reasonable impacts to retail electricity prices. The analysis includes the specific operating parameters
and variability of other technologies and coal types, and is unlikely to lead to extensive substitution
away from coal-fired generation. Thus reliability issues are not expected to be significant. Industry has
shown that it can install large amounts of pollution controls and often finds more cost-effective
compliance options than the EPA can anticipate. In addition, the EPA has analyzed resource adequacy

563


-------
issues and finds that there is ample existing spare capacity to serve load, and industry has also shown
that it can build new capacity quickly in response to demand.

Comment 57: Commenter 18907 reports that a provider in the midwest has announced the shutdown of
up to 25% of its coal-fired generating capacity, which will increase electricity rates. This price increase
will impact businesses and create problems with remaining competitive for manufacturers.

Response to Comment 57: The EPA has conducted detailed impact analysis of the rule, which shows
reasonable impacts to retail electricity prices. The analysis includes the specific operating parameters
and variability of other technologies and coal types, and is unlikely to lead to extensive substitution
away from coal-fired generation. Industry has shown that it can install large amounts of pollution
controls and often finds more cost-effective compliance options than the EPA can anticipate. In addition,
many announced coal retirements are due to reasons not related to EPA actions, such as low natural gas
prices and lower electricity demand. These units are typically the oldest and least efficient units in the
coal fleet.

Comment 58: Commenter 18933 states that textile production in North and South Carolina and Georgia
will suffer from an estimated increase of 11.5%. This expense is likely to make the industry less
competitive with foreign businesses.

Response to Comment 58: Retail electricity prices are projected to increase roughly 3.1% in 2015
nationwide, based on the agency's analysis contained in the RIA for the rule. This increase, while not
trivial, is not expected to yield significant impacts to manufacturers. The EPA's analysis indicates that
coal-fired generation will maintain its large share of generation. In addition, industry has shown that it
can install large amounts of pollution controls and often finds more cost-effective compliance options
than the EPA can anticipate. The EPA has conducted detailed impact analysis of the rule, which shows
reasonable impacts to retail electricity prices. The analysis includes the specific operating parameters
and variability of other technologies and coal types, and is unlikely to lead to extensive substitution
away from coal-fired generation. Industry has shown that it can install large amounts of pollution
controls and often finds more cost-effective compliance options than the EPA can anticipate.

Comment 59: Commenter 18502 expresses concerns about the impact the proposed rule will have on
Puerto Rico when the costs of compliance are passed on to consumers. The commenter points out that
the impacts of the proposed rule on the local economy will limit the economic recovery and increase
electricity costs that are already twice those of the continental U.S. The commenter estimates that 70%
of the electricity on the island is oil-fired generation and 10-15% of the consumers' costs are for fuel, so
the proposed rule will strongly impact the system reliability and costs, despite having little benefit to an
island with trade winds that produce excellent air quality. The commenter asks that the EPA reconsider
controlling emissions from oil-fired units since the HAP emissions are much lower than from coal-fired
units and the compliance costs are much higher.

Response to Comment 59: The EPA has conducted detailed impact analysis of the rule, which shows
reasonable impacts to retail electricity prices. The analysis includes the specific operating parameters
and variability of other technologies and coal types, and is unlikely to lead to extensive substitution
away from coal-fired generation. In addition, separate standards are being finalized for non-continental
oil-fired EGUs (see preamble).

Comment 60: Commenter 18538 states that the Texas economy and service reliability will be impacted
by the proposed new rule. The commenter believes the proposed rule will negatively impact residential

564


-------
customers and energy-intensive business and the jobs they create. The commenter points out that
environmental regulations in Europe have sent manufacturing businesses elsewhere. Commenters 18538
and 13526 state that because Texas generates more energy from coal than any other state (more than
60% greater than the next highest state) and almost 10% of the total amount for the U.S., the state's
generation fleet will be disproportionately impacted and a large amount of retirements will occur, and
the future of planned plants is in question. Commenters cite various studies and power plant closing
announcements which show the likely retirement rate to be far beyond that estimated by the EPA. All of
this makes reliability an issue in the state, with one study estimating a reserve margin of -8.6%. The
commenter states that the EPA's impacts analyses are flawed and asks that they be revised to consider
the full impact of all the new and proposed rules.

Response to Comment 60: The EPA has conducted detailed impact analysis of the rule, which shows
reasonable impacts to retail electricity prices. The analysis includes the specific operating parameters
and variability of other technologies and coal types, and is unlikely to lead to extensive substitution
away from coal-fired generation. Industry has shown that it can install large amounts of pollution
controls and often finds more cost-effective compliance options than the EPA can anticipate. In addition,
the EPA has analyzed resource adequacy issues and finds that there is ample existing spare capacity to
serve load, and industry has also shown that it can build new capacity quickly in response to demand.
The EPA will work with relevant authorities to ensure a smooth transition with this rule. Public utility
commissions and other regulatory authorities have extensive experience with regulatory requirements
and treatment of costs to consumers, and are prepared for responding to the cost of future pollution
control equipment or other response measures. In addition, there are certain provisions for granting
utilities some additional time to comply, if conditions warrant (see preamble).

Comment 61: Commenter 18538 states that a competitive market will affect decisions about retrofitting
or retirement of a plant. The commenter explains that a merchant generator selling into a competitive
market, like that in ERCOT bears the cost and risk of the investment because there is no guarantee of
recovering the costs to retrofit.

Response to Comment 61: The requirements of the CAA do not distinguish between energy markets,
and participants in competitive markets understand the risks inherent in those markets, such as the
potential costs associated with pollution controls. In addition, these markets are largely driven by the
cost of the marginal producing electricity generating unit(s), which is most often natural gas. Industry
has shown that it can install large amounts of pollution controls and often finds more cost-effective
compliance options than the EPA can anticipate, irrespective of whether it is located in cost of service or
competitive markets.

Comment 62: Commenter 18538 considers the EPA's predictions about energy efficiency mitigating
impacts of the proposed rule and explains that Texas has a robust efficiency program, but estimates it
will only offset 681 MW of demand in 2015 and 1,448 MW in 2020, a total of 1% in 2015 and 2% in
2020.

Response to Comment 62: The EPA believes energy efficiency measures can be a complement to this
rule, and can be an important tool in helping address emissions. The EPA has not included all the likely
additional energy efficiency measures that are likely to occur by 2015, but will continue to pursue
energy efficiency improvements throughout the economy, along with other federal agencies, states and
other groups. This will contribute to additional environmental and public health improvements while
lowering the costs of realizing those improvements.

565


-------
Comment 63: Commenters 17137 and 18021 believe that if the proposed rule is implemented with the
current timeline and stringency, industry in the southeast, which relies on affordable, reliable electricity,
will be weakened, jobs will be lost, and power consumers will be hurt. Commenters point out that the
southeast is particularly vulnerable to the proposed rule because it relies heavily on manufacturing and
provides hundreds of thousands of jobs and billions in economic impact as a result. Commenters state
that the abundant, reliable and inexpensive electricity from native coal resources is a factor in the
thriving skilled labor market and foreign manufacturing investment. Commenter 18021 points out that
regulated utilities have no choice but to pass cost increases on to customers. The commenter also
explains that in addition to capital costs, the addition of control technology reduces efficiency of the
plants, increasing fuel costs.

Response to Comment 63: The implementation date for this rule is set to be consistent with the
requirements of the CAA for standards such as these. Retail electricity prices are projected to increase
roughly 3.1% in 2015 nationwide, based on the agency's analysis contained in the RIA for the rule. This
increase, while not trivial, is not expected to yield significant impacts to manufacturers. The EPA's
analysis indicates that coal-fired generation will maintain its large share of generation. In addition,
industry has shown that it can install large amounts of pollution controls and often finds more cost-
effective compliance options than the EPA can anticipate.

Comment 64: Commenters 17712 and 17743 explain that cooperative EGUs will generally need to add
controls to comply with the proposed rule, and others will need to shut down because they will be
unable to comply in a cost-effective and timely manner.

Response to Comment 64: The EPA will work with relevant authorities to ensure a smooth transition
with this rule. In addition, there are certain provisions for granting utilities some additional time to
comply, if conditions warrant (see preamble). The EPA analysis also indicates that there will be
relatively modest amounts of retirements and installation of pollution controls will be a cost-effective
compliance measure. In addition, many coal facilities have already invested in pollution controls, and
they are well positioned to comply with this rule with modest changes to operations.

Comment 65: Commenter 17718 considers the proposed rule to be hardest on states which rely heavily
on coal-fired plants and uses Kentucky as a state which is jeopardized by the proposed rule due to the
loss of inexpensive electricity giving it a competitive advantage at attracting industry. Kentucky runs the
risk of seeing lucrative local businesses such as auto plants leave the region if electricity prices increase
due to the proposed rule.

Response to Comment 65: The EPA's analysis indicates that coal-fired generation will maintain its
large share of generation. In addition, industry has shown that it can install large amounts of pollution
controls and often finds more cost-effective compliance options than the EPA can anticipate.

Comment 66: Commenter 17055 mentions that their initial assessment did not consider impacts the
RICE regulations may have on the potential loss of small units relied upon by many municipalities.
Elimination of these units could, the commenter believes, lead to local congestion and require
transmission expansion and local programs to meet demand. The commenter believes that working with
the industry to institute these changes will help preserve reliable system operations and also allow for a
more gradual integration of the costs of compliance that could significantly mitigate reliability issues
and sudden increases in consumer electricity prices.

566


-------
Response to Comment 66: The agency is currently reconsidering the Compression Ignition and Spark
Ignition RICE NESHAP. The outcome of this reconsideration may affect the congestion and other issues
the commenter points out.

Comment 67: Commenter 17821 explains the additional hardships for small cooperative utilities, which
often share several small units in order to split the risk and increase reliability. The commenter believes
the EPA has not fully recognized the impact of the proposed rule on these small entities. The commenter
does not believe that the work practice standards, subcategorization, health-based compliance options or
emissions averaging will adequately reduce the burden to such organizations and their financial well-
being will be strained by the proposed rule. The commenter believes more flexibility is needed, as well
as more time, to minimize risk to small businesses.

Response to Comment 67: The EPA will work with relevant authorities to ensure a smooth transition
with this rule. In addition, there are certain provisions for granting utilities some additional time to
comply, if conditions warrant (see preamble). The EPA analysis also indicates that there will be
relatively modest amounts of retirements and installation of pollution controls will be a cost-effective
compliance measure. In addition, many coal facilities have already invested in pollution controls, and
they are well positioned to comply with this rule with modest changes to operations.

Comment 68: Commenter 17745 expresses concern over the impacts on the Georgia state economy by
the proposed rule, especially the increased cost of electricity and the impacts on residents and
businesses.

Response to Comment 68: The EPA has conducted detailed impact analysis of the rule, which shows
reasonable impacts to retail electricity prices. Industry has shown that it can install large amounts of
pollution controls and often finds more cost-effective compliance options than the EPA can anticipate.
The EPA will work with relevant authorities to ensure a smooth transition with this rule. In addition,
there are certain provisions for granting utilities some additional time to comply, if conditions warrant
(see preamble). Although certain regions will need to do more in order to comply, those same regions
will also benefit from the emission reductions. Overall, coal use is not anticipated to be greatly impacted
as coal-fired sources install pollution controls, with only modest amounts of retirements. Retail
electricity prices are projected to increase slightly on average by 2015. Thus, there may be some
negative impacts from this rule in these regions, but these same regions will also experience some of the
benefits, such as reduced premature mortality from less exposure to PM2.5 emissions as shown in
Appendix C of the RIA. In addition, the EPA has conducted an updated employment analysis which
shows some potential positive and negative employment changes from the rule, but overall expects the
employment impact to be relatively small in comparison to the affected sector and the overall economy.

Comment 69: Multiple commenters (16705, 17400, 17697, 17868, 18038, 18433) consider the EPA's
RIA to be flawed in suggesting that only 97 municipal utilities will face a compliance cost of $666.30
million annually. Commenter 16705 states that these costs underestimate the impact on states such as
Indiana, Ohio, Wisconsin, Michigan, Minnesota, Kentucky, Georgia, Alabama and Texas. Commenter
17400 notes that these costs ignore Guam, where an additional $49 to $103 million is expected to be
spent in capital costs with $1.2 to $2.6 million in annual costs. Commenter 17697 explains that the cost
analysis does not include the cost of purchasing power during scheduled outages for retrofit, the costs of
fuel switching, or the inability to sell coal ash or coal combustion residuals to the cement industry.
Footnotes pertaining to the coal ash include a reference and an estimate that fly ash would cost an extra
$100 million over 20 years for disposal.

567


-------
Response to Comment 69: The EPA has conducted detailed impact analysis of the rule, which shows
reasonable impacts to retail electricity prices. The EPA has also updated its UMRA analysis. Industry
has shown that it can install large amounts of pollution controls and often finds more cost-effective
compliance options than the EPA can anticipate. The EPA will work with relevant authorities to ensure
a smooth transition with this rule. In addition, there are certain provisions for granting utilities some
additional time to comply, if conditions warrant (see preamble). There are also separate standards for
non-continental liquid oil-fired EGUs. The EPA is addressing coal combustion residuals in a separate
rulemaking.

Comment 70: Several commenters (17689, 17697, 17710, 18433) explain Guam's dependence on a
single fuel-oil electric utility plant to provide all of the island's power. This situation leads the
commenters to believe the island will be significantly impacted in energy costs and reliability as a result
of the proposed rule. Commenters 17710 and 18433 state the rule's burden is unacceptable and that the
cost of energy is a more significant part of household and business expense than nationally. Commenter
17698 requests that acid gases not be regulated under the proposed rule, since it will increase costs and
make compliance more difficult. Commenters 17697 and 18433 believe the electricity rates will
increase, especially since 70% of the cost of Guam's power production comes from fuel costs. The
commenters believe this rate increase will increase unemployment and cause economic hardship for the
already disproportionately high percentage of the island's population currently unemployed or
underemployed.

Response to Comment 70: The EPA is required to regulate acid gas HAP such as hydrochloric and
hydrofluoric acids under this rule, as explained elsewhere in the final rule record. As to impacts to
Guam, the agency will limit the impact of this rule on the power plant to that consistent with the CAA
and note that in the final rule, we have established a subcategory for non-continental liquid oil-fired
EGUs that should address some of commenters' concerns.

Comment 71: Commenter 17730 estimates that the proposed rule will cost hundreds of millions of
dollars in initial capital costs for their region, which will be passed on to consumers in some of the top
100 poorest counties in the country.

Response to Comment 71: The agency's analysis of changes in the national average retail electricity
price associated with this rule finds is projected to be 3.1% in 2015. If this increase in retail electricity
price is a concern, then state and local agencies are best equipped to manage rate structures to mitigate
any impacts associated with this increase. In addition, the increase in retail electricity price should be
understood in light of the substantial benefits (including co-benefits).

Comment 72: Commenter 17791 requests that the EPA avoid compromising energy system reliability,
seek ways to minimize cost impacts, ensure availability of electricity and natural gas, consider
cumulative impacts of multiple rules and employ rigorous cost-benefit analyses. The commenter also
suggests the EPA consider regional differences that will impact system reliability and costs, such as the
increased impacts on regions relying heavily on coal and oil and encourages cooperation between the
EPA and state and federal energy and environmental regulators.

Response to Comment 72: The agency has studied possible impacts on reliability as a result of this
rule, and has determined that these impacts should not be significant. The agency has prepared a detailed
TSD to document this study, and this document is the docket for this rulemaking. The agency has
considered impacts on a regional basis as part of its overall analyses done using the IPM; these results
are documented in the RIA for the rule and in several TSDs.

568


-------
Comment 73: Commenter 18497 says the group's six "footprint states" generated over 67% of their
electricity from coal in 2009, varying from 36.5% in Virginia to 96.2% in West Virginia. The
commenter says the variability of the impacts will be similar and should be considered by the EPA.
Based on age alone, the commenter states that over 28% of the region's summer generating capacity
(143 units) can be considered at risk for retirement due to the proposed rule.

Response to Comment 73: The EPA has conducted detailed impact analysis of the rule, which shows
that coal will remain the largest source of electricity. The agency has estimated that less than 2% of all
coal-fired generating capacity may be uneconomic to maintain and removed form operation by 2015 in
response to the rule, and this result is the product of business decisions rather than a specific requirement
of the rule. In addition, the EPA has analyzed resource adequacy issues and finds that there is ample
existing spare capacity to serve load, and industry has also shown that it can build new capacity quickly
in response to demand and also manage the installation of pollution controls. The EPA will work with
relevant authorities to ensure a smooth transition with this rule. Public utility commissions and other
regulatory authorities have extensive experience with regulatory requirements and treatment of costs to
consumers, and are prepared for responding to the cost of future pollution control equipment or other
response measures. In addition, there are certain provisions for granting utilities some additional time to
comply, if conditions warrant (see preamble).

Comment 74: Commenter 17829 explains that their power supplier estimated that if scrubbers are
required for their plant, the cost could reach $1 billion. The commenter goes on to state that the resulting
cost increase will most impact the elderly, poor and those who have lost jobs at a time when the Low
Income Home Energy Assistance Program has been decreased significantly.

Response to Comment 74: The rule does not dictate any particular technology and the EPA has
attempted to provide the maximum degree of flexibility to source owners within the limitations of the
CAA. The EPA has conducted detailed impact analysis of the rule, which shows reasonable impacts to
retail electricity prices. The analysis indicates that coal will remain the largest source of electricity.
Industry has shown that it can install large amounts of pollution controls and often finds more cost-
effective compliance options than the EPA can anticipate. In addition, the EPA has analyzed resource
adequacy issues and finds that there is ample existing spare capacity to serve load, and industry has also
shown that it can build new capacity quickly in response to demand and also manage the installation of
pollution controls. The EPA will work with relevant authorities to ensure a smooth transition with this
rule. Public utility commissions and other regulatory authorities have extensive experience with
regulatory requirements and treatment of costs to consumers, and are prepared for responding to the cost
of future pollution control equipment or other response measures. In addition, there are certain
provisions for granting utilities some additional time to comply, if conditions warrant (see preamble).

Comment 75: Commenter 17884 quotes NMA statistics showing coal is responsible for $65,738 billion
in annual economic activity, produces 1,798,800 jobs and $36,345 billion in annual labor income. The
commenter reports that regions such as Appalachia, the midwest and Rocky Mountain west will be
significantly affected by the rule, including increased unemployment.

Response to Comment 75: The agency's analysis as found in the RIA shows that the overall impact of
the rule to be relatively small, in the context of the entire power sector. Although certain regions will
need to do more in order to comply, those same regions will also benefit from the emission reductions.
Overall, coal use is not anticipated to be greatly impacted as coal-fired sources install pollution controls,
with only modest amounts of retirements. Retail electricity prices are projected to increase slightly on
average by 2015. Thus, there may be some negative impacts from this rule in these regions, but these

569


-------
same regions will also experience some of the benefits, such as reduced premature mortality from less
exposure to PM2.5 emissions as shown in Appendix C of the RIA. In addition, the EPA has conducted an
updated employment analysis which shows some potential positive and negative employment changes
from the rule, but overall expects the employment impact to be relatively small in comparison to the
affected sector and the overall economy.

Comment 76: Commenters 17901 and 18023 state that communities near existing coal-fired generation
units will be especially hard-hit if the plants are permanently retired. The communities will suffer from
job loss and diminished tax revenue.

Response to Comment 76: Although it is possible that there may be some negative local economic
impacts associated with this rule, impacts such as retail electricity price increases should be modest.
Also, the estimated number of early retirements according to the agency that may result from this rule is
4.7 GW in 2015, or about 2% of all U.S. coal-fired capacity in that year. Overall, coal use is not
anticipated to be greatly impacted as coal-fired sources install pollution controls, with only modest
amounts of retirements. These results are presented in the RIA for the rule. In addition, the EPA has
conducted an updated employment analysis which shows some potential positive and negative
employment changes from the rule, but overall expects the employment impact to be relatively small in
comparison to the affected sector and the overall economy. Although certain regions will need to do
more in order to comply, those same regions will also benefit from the emission reductions such as
through reduced premature mortality from less exposure to PM2.5 emissions as shown in Appendix C of
the RIA.

Comment 77: Several commenters (18422, 18433, 18575) request that the EPA reconsider the
regulating of acid gases as they are not required and will impose greater cost and difficulty. The
commenters ask that the rule be reevaluated to be more realistic and cost-effective.

Response to Comment 77: The agency believes the regulation of acid gases that are HAP is both
required and appropriate under this rule. The preamble to this rule provides the rationale for this
position.

Comment 78: Commenter 18447 disagrees with the EPA's assessment that the reductions can be
achieved without significantly affecting availability or cost of electricity and with an increase in jobs.
The commenter expects job losses from the proposed rule and explains that the City of Ames, Iowa has
one base load plant and two diesel combustion turbine "peakers" and cannot shift power away from
older units to newer plants. The commenter explains that while switching to natural gas may seem like
the preferred compliance option, there is not enough of a natural gas supply to support the needed
generation. Also, the city's power plant provides disposal for all municipal solid waste for the city and a
neighboring town and the units would not be able to burn the refuse-derived fuel if it converted to
natural gas. Thus, a fuel switch would lead to a dilemma for disposal of solid waste.

Response to Comment 78: The EPA has conducted detailed impact analysis of the rule, which shows
reasonable impacts to retail electricity prices. The analysis indicates that coal will remain the largest
source of electricity. The EPA will work with relevant authorities to ensure a smooth transition with this
rule and address specific issues. Public utility commissions and other regulatory authorities have
extensive experience with regulatory requirements and treatment of costs to consumers, and are prepared
for responding to the cost of future pollution control equipment or other response measures. In addition,
there are certain provisions for granting utilities some additional time to comply, if conditions warrant
(see preamble).

570


-------
Comment 79: Commenter 17648 offers projections showing that 2015 electricity prices in most areas
will be the same or lower than they were in 2010 as a result of the proposed rule. The commenter
retained NorthBridge Group to estimate the potential rate impact resulting from the proposed rule on its
customers in both the ComEd and PECO service territories. NorthBridge concluded that, based on
current market conditions, generation rates in 2015 will be less than 2010 levels on an inflation-adjusted
basis. NorthBridge reports that this finding is in partly due to the decline in natural gas prices in recent
years. Exelon's customers will benefit from lower gas prices, and this price decline will mitigate any
potential rate increases related to the Toxics Rule. The results of NorthBridge's analysis are set forth in
Figure 1 (See 17648-A2_Figure IComEd and PECO Generation Rates.docx).

Response to Comment 79: The Commenter's statements are not inconsistent with the results of EPA's
analysis, which indicates that impacts on retail electricity and natural gas prices of the rule will be
reasonable in light of the large benefits.

Comment 80: Commenter 17676 offers suggestions of things consumers and regulators can do to
mitigate the impact of increasing electricity costs.

1.	The commenter discusses the establishment of centralized entities that provide revenue for power
plants to provide power to the grid when necessary, called "capacity markets." The commenter
suggests that capacity markets need more oversight to ensure newer, more advanced facilities take
precedence over less efficient plants because Synapse Energy Economics states that capacity
markets keep electricity prices high and less efficient plants operating.

2.	The commenter also suggests pushing FERC to be more proactive about market violations by
encouraging competitive regional markets with balanced rules, monitoring such markets for
anticompetitive behavior and enforce market rules.

3.	The commenter also suggests better energy efficiency programs for domestic and imported electric
products and better building codes to decrease energy demand can save consumers money and limit
the amount of pollution released by EGUs.

Response to Comment 80: We thank the commenter for these suggestions. The agency has worked
with FERC and other Federal agencies to examine ways of mitigating potential negative consequences
associated with this rule. The EPA believes that there are many approaches that can help mitigate price
increases, and is a strong supporter of energy efficiency measures. The EPA will work with relevant
authorities to ensure a smooth transition with this rule and address specific issues. Public utility
commissions and other regulatory authorities have extensive experience with regulatory requirements
and treatment of costs to consumers, and are prepared for responding to the cost of future pollution
control equipment or other response measures.

Comment 81: Several commenters (17682, 17884, 18033, 18484, 18023) consider the proposed rule to
be a tax on the American public, since utilities implementing upgrades will pass the costs on to the
consumer. Commenter 17682 questions the preference of Americans to subsidize renewable energy
sources and put money into the proposed rule instead of other environmental programs with greater
benefits. Commenters 17884 and 18484 explain that the tax-like price increase reduces income of
energy consumers and depresses business development. The commenters used California as an example
of a state that uses low rates of coal-based electricity and cite companies that have left the state as a
result of substituting higher-cost forms of electricity for coal. Commenter 18033 states that coal-derived
energy will rapidly become more expensive, especially in the "rust belt" and southeast region, as can be
seen by the rate increase already requested in Louisville. Commenter 18023 believes the "indirect
taxation" limits the ability of the economy to absorb the cost of retrofitting and new capacity projects,

571


-------
lowers discretionary spending lead to job losses and lost tax revenues, given the restrictive timeframe for
compliance.

Response to Comment 81: The EPA has conducted detailed impact analysis of the rule, which shows
reasonable impacts to retail electricity prices. The analysis indicates that coal will remain the largest
source of electricity. Industry has shown that it can install large amounts of pollution controls and often
finds more cost-effective compliance options than the EPA can anticipate. In addition, the EPA has
analyzed resource adequacy issues and finds that there is ample existing spare capacity to serve load,
and industry has also shown that it can build new capacity quickly in response to demand and also
manage the installation of pollution controls. Although electricity consumers will likely see a small price
increase, it should be noted that these consumers will also experience the improvement in air quality
from the reductions due to the rule, and the benefits of this improvement will greatly exceed costs. The
price increases in electricity and natural gas should be considered in light of the substantial benefits
offered by this rule. In addition, history has shown that the impact of EPA regulations is much lower
than anticipated, and predictions of severe economic impact have been often repeated, but not realized.

Comment 82: Commenters 16705 and 18038 believe the proposed rule will have a significant impact on
jobs in their community and increase the electric rate, driving out businesses.

Response to Comment 82: The EPA has conducted detailed impact analysis of the rule, which shows
reasonable impacts to retail electricity prices. The analysis indicates that coal will remain the largest
source of electricity. Industry has shown that it can install large amounts of pollution controls and often
finds more cost-effective compliance options than the EPA can anticipate. In addition, the EPA has
conducted an updated employment analysis which shows some potential positive and negative
employment changes from the rule, but overall expects the employment impact to be relatively small in
comparison to the affected sector and the overall economy.

Comment 83: Commenters 16856 and 18038 believe the proposed rule will severely impact the
economy of the coal-producing states and utilities that provide almost 50% of their electricity from coal.
Commenters ask that the EPA bring jobs back to the U.S. and stop sending manufacturing jobs to
countries where environmental impacts are not considered.

Response to Comment 83: The EPA has conducted detailed impact analysis of the rule, which shows
reasonable impacts to retail electricity prices. The analysis indicates that coal will remain the largest
source of electricity. Industry has shown that it can install large amounts of pollution controls and often
finds more cost-effective compliance options than the EPA can anticipate. In addition, the EPA has
conducted an updated employment analysis which shows some potential positive and negative
employment changes from the rule, but overall expects the employment impact to be relatively small in
comparison to the affected sector and the overall economy.

Comment 84: Commenter 17627 considers the EPA's RIA document to be lacking in local economic
impacts associated with reduced operations or plant closures.

Response to Comment 84: The EPA has conducted detailed impact analysis of the rule, which includes
regional information and impacts, and more detail can be found in the corresponding IPM output files
for the final rule, which has detail for the 32 power regions across the country. In addition, the EPA has
conducted an updated employment analysis which shows some potential positive and negative
employment changes from the rule, but overall expects the employment impact to be relatively small in
comparison to the affected sector and the overall economy.

572


-------
Comment 85: Commenter 17701 mentions that the proposed rule will have different reliability and cost
effects on different regions of the country due to differing resources, transmission and capacity, market
structures, approaches to energy efficiency, transmission options, electricity demand projections and
consumer concerns.

Response to Comment 85: The EPA has conducted detailed impact analysis of the rule, which shows
reasonable impacts to retail electricity prices. The analysis provides a rich characterization of regional
issues, and reflects the differences in the power sector composition across those regions. The impact of
the rule will vary across regions, and the EPA has presented some of those impacts in the RIA.

Comment 86: Commenter 18030 quotes the NERA study could cost Michigan 40,000 jobs and increase
electricity prices by 20.5% in 2016 and likely lead to the closing of numerous Michigan plants. The
commenter requests the implementation of the proposed rule be suspended.

Response to Comment 86: The EPA has designed a rule that is intended to offer flexibility, to the
extent possible, while ensuring public health is protected in accordance with requirements outlined in
the CAA. History has shown that industry adapts to regulations and finds more cost-effective
compliance approaches that the EPA can anticipate or predict, thus lowering the actual cost of its rule
relative to what the EPA initially projected. The EPA has conducted detailed economic impacts analysis
on the regulated sector, and finds the impact of the rule on the regulated sector is small compared to the
overall benefits, and the industry has an excellent track record of installing pollution controls without
greatly impacting electricity prices. The report cited by the commenter is not transparent with regards to
several key criteria, and it is thus impossible to fully assess the credibility of the results. It has often
been claimed that regulations do harm to the economy and jobs, but the evidence is weak or nonexistent,
while there is a large body of literature that shows overall, the impacts of regulations on jobs and the
economy is very small.

Comment 87: Several commenters (17705, 17732, 18540) discuss the unique situation of the Navajo
Generating Station (NGS), which plays a key role in water delivery to Native American communities,
farmers and cities in Arizona and which provides critical energy to the region. The plant also provides
good jobs to 540 skilled workers and provides economic support for several communities through tax
payments and other jobs. The plant also helps the U.S. meet its federal trust responsibilities under the
2004 Arizona Water Settlements Act, and provides power and funding for the Central Arizona Project
(CAP). The commenter states that the IPM model defines the plant as uneconomic to maintain, but given
the importance of the facility, the owners want to work with the EPA to retain the plant. The commenter
believes the NGS should not have to install a baghouse to comply with the proposed rule and asks that
the EPA evaluate all impacts of closure on the Navajo Nation on a regional economic basis, rather than
on a Nation-wide basis. Commenter 18017 agrees with these comments and expresses concern about the
closing of NGS affecting many entities, if sufficient time isn't given for compliance. The commenter
details the difficulties to this region of Arizona would have in finding alternative power sources for
electricity use and to pump water. The commenter estimates pumping costs could go up 50-300% by
2017. Commenter 18540 explains that it receives its entire water supply through the CAP system and is
concerned with the effect of the proposed rule on the viability of the CAP. The commenter stresses the
fact that the U.S. government owes a trust responsibility to commenter and other Indian tribes, including
water rights. The commenter explains that it gave up its right to assert water claims held from "time
immemorial" in return for specific provisions by the U.S. government of water from the CAP and
Yuma-Mesa Division of the Gila project. The commenter explains the various water settlement
legislation in place and urges the EPA to carefully consider the possible effects of its proposed
rulemaking on the continuing viability of the CAP system and requests that the EPA consult with it and

573


-------
other tribes that may be affected by the proposed rule, pursuant to the Agency's May 2011 Consultation
Policies.

Comment 88: Commenters 17732 and 18017 report that the power plant associated with the Navajo
Nation (FCPP) employs nearly 600 people, most of them Navajo Nation members. The commenter goes
on to explain that the Navajo Mine provided $69 million into the Navajo Nation's revenue in 2007 and
employs 427 people, 87% of whom are Navajo tribal members. The Peabody Kayenta Mine employs
another 400 workers, many of whom are Native American. Revenue from the power plants and mines
that supply them make up 1/3 of the general operating budget of the Navajo Nation, which employs
another 7,316 people, 98% of whom are Navajo. The Hopi tribe estimates that revenues derived from
the plants and mines make up 88% of their tribe's operating budget. Details of this revenue and
supporting numbers may be found at: http://www.navaiobusiness.com/pdflCEDS/CED NN
Final 09 10.pdf.

Comment 89: Commenter 17732 describes the impact of EPA regulation shutting down the Mohave
Generating Station, which led to the closing of the Black Mesa Mine. The commenter explains that 160
people were put out of work at the mine, and Navajo Nation's general revenue was decreased by 30%.
The commenter states that if the proposed regulations lead to a shutdown of the remaining two power
plants due to cost-prohibitive emission controls, the mines supplying them would also close. These
closures would lead to revenue and job losses so extreme they would impugn the solvency of the Navajo
Nation government. The commenter states that the EPA failed to analyze the impacts to the Navajo
Nation as part of the impact analysis. The commenter points out that unemployment is over 50% among
the Navajo people, and no skilled labor force or industry exists in the pollution control technology field
among their population. Therefore, the new jobs expected to be created by the proposed rule would not
help the Navajo Nation, but the closing of the coal and power industry would lead to the loss of 31,000
jobs. This would force migration of many workers, a "social cost" not analyzed by the EPA.

Comment 90: Commenter 19214 requests that the Table 8.8 showing thatNGS will be likely to shut
down by 2015 be changed to show continued operation of this important coal-fired plant. The owners
acknowledge that the rule will be challenging, but are committed to working with the EPA to keep this
critical resource open.

Response to Comments 87-90: The EPA modeling and projections are intended to be a reflection of
possible compliance using specific tools, assumptions, and methodologies that the agency believes to
reflect the best and most current information related to the power sector. It is not intended to reflect
actual compliance decisions, since those will be made individually by the affected industry based on
what makes most sense using existing technologies or other, more cost-effective strategies. The EPA
will work with relevant authorities to ensure a smooth transition with this rule and address specific
issues as they arise. Public utility commissions and other authorities, such as tribes, will need to develop
and implement compliance plans in order to address harmful emissions.

Comment 91: Commenters 17807 and 17901 expresses concern about economic impacts to residential
and commercial customers, particularly minorities, the elderly and economically disadvantaged
customers.

Response to Comment 91: The EPA has conducted detailed impact analysis of the rule, which shows
reasonable impacts to retail electricity prices. The average impact on household energy expenditures
(electricity and gas) is anticipated to be less than $3 per month.

574


-------
Comment 92: Commenter 17813 questions the results of the IPM model because it shows a heat input
of 25.353 TBtu for their facility, while average from 2006-2010 is 35.285 TBtu. Because of this
discrepancy, the commenter questions the assumption that the plant will retire.

Response to Comment 92: The EPA modeling and projections are intended to be a reflection of
possible compliance using specific tools, assumptions, and methodologies that the agency believes to
reflect the best and most current information related to the power sector. It is not intended to reflect
actual compliance or retirement decisions, since those will be made individually by the affected industry
based on what makes most sense using existing technologies or other, more cost-effective strategies.

Comment 93: Commenter 17815 reports that in 2010, coal-fueled generation provided approximately
40% of electricity in the Electric Reliability Council of Texas region and provided over 33,000
permanent jobs as well as $10 billion in annual expenditures. The commenter says that the average
income for a lignite mining employee in Texas is 2.14 times the state average income for all industries
and has a tax contribution of $1,012 billion.

Response to Comment 93: The EPA has conducted detailed impact analysis of the rule, which provides
a rich characterization of regional issues, and reflects the differences in the power sector composition
across those regions. The impact of the rule will vary across regions, and the EPA has presented some of
those impacts in the RIA. Overall, coal-fired generation is not expected to change significantly since
sources are anticipated to install pollution controls. In addition, the EPA has conducted an updated
employment analysis which shows some potential positive and negative employment changes from the
rule, but overall expects the employment impact to be relatively small in comparison to the affected
sector and the overall economy

Comment 94: Commenter 17901 questions the benefits of the proposed rule in the face of job losses
likely to hit coal-producing regions especially hard. Commenter 18500 agrees and points out that some
regions will see almost no impact from the rules, such as the Pacific northwest while the midwest and
other regions will face large cost increases.

Response to Comment 94: The EPA has conducted detailed impact analysis of the rule, which provides
a rich characterization of regional issues, and reflects the differences in the power sector composition
across those regions. The impact of the rule will vary across regions, and the EPA has presented some of
those impacts in the RIA. Overall, coal-fired generation is not expected to change significantly since
sources are anticipated to install pollution controls. In addition, the EPA has conducted an updated
employment analysis which shows some potential positive and negative employment changes from the
rule, but overall expects the employment impact to be relatively small in comparison to the affected
sector and the overall economy.

Comment 95: Commenter 18430 cites a Unions for Jobs and the Environment (UJAE) study that
estimated job losses due to the proposed rule to be over 250,000, with more than 11,000 in Virginia. The
commenter states that the importance of the coal industry to Virginia makes that state especially painful.

Response to Comment 95: The EPA has conducted detailed impact analysis of the rule, which provides
a rich characterization of regional issues, and reflects the differences in the power sector composition
across those regions. The impact of the rule will vary across regions, and the EPA has presented some of
those impacts in the RIA. Overall, coal-fired generation is not expected to change significantly since
sources are anticipated to install pollution controls. In addition, the EPA has conducted an updated
employment analysis which shows some potential positive and negative employment changes from the

575


-------
rule, but overall expects the employment impact to be relatively small in comparison to the affected
sector and the overall economy.

Comment 96: Commenter 18477 believes that non-continental oil-fired EGUs should have a separate
regulatory impact analysis. The commenter explains that non-continental utilities have fewer economic
resources available to address proposed rule requirements and as regulated utilities they must obtain
approval for rate increases to offset costs. Since non-continental electricity prices are already higher than
on the continental U.S. the economic consequences associated with compliance are also higher.

Commenter 17760 states that the EPA should conduct a separate RIA for non-continental oil-fired
EGUs. According to the commenter, in March 2011, the EPA released the RIA of the Proposed Toxics
Rule: Final Report. The commenter states that the RIA utilized an Integrated Planning Model ("IPM") to
predict the costs associated with the proposed rule, as well as its effect on the economy and public
health. The commenter asserts that the RIA only addressed coal-fired EGUs; the EPA stated that it
would address regulatory impacts related to liquid oil-fired units in the final rule. Of the 154 oil-fired
EGUs identified in the proposed rule, 31 of the units are located on the islands of Oahu, Puerto Rico,
and Guam. The commenter states that since the EPA intends to analyze regulatory impacts related to oil-
fired units as part of the final rulemaking, the EPA should address non-continental liquid oil-fired units
separately in that analysis.

Response to Comment 96: The final rule contains provisions that are specific to non-continental liquid
oil-fired EGUs. See preamble for further discussion of the treatment of these sources.

3. Retiring coal-fired EGUs, shutdowns.

Comment 97: Commenter 17403 says that capital that will be deployed by EGU owners to implement
emissions control measures under the proposed rule should create well-paying jobs for skilled workers
across the country. However, the commenter goes on to say that premature shutdown of existing coal-
fired EGUs will also result in an estimated 50,000 direct job losses in the coal, utility and rail industries
with a total job loss including indirect jobs of 251,300. The commenter considers the costs and benefit
analyses of the proposed rule to be incomplete and misleading and the proposed rule structured to avoid
unnecessarily eliminating jobs.

Response to Comment 97: The EPA analysis indicates that there will be a small amount of coal
retirements (less than 2% of all coal-fired capacity). In addition, the EPA has conducted an updated
employment analysis which shows some potential positive and negative employment changes from the
rule, but overall expects the employment impact to be relatively small in comparison to the affected
sector and the overall economy.

Comment 98: Multiple commenters (17623, 17656, 17834, 17868, 17930, 18018, 18497, 18023)
discussed predictions for the number of coal-fired EGUs that are likely to retire as a result of the
proposed rule and Transport rule. Several commenters (17623, 17868, 18497, 18023) cite and provide
references to seven studies predicting retirements of 5 to 65 GW in 2015, where six of the seven predict
retirements of 35 GW or more. Commenter 17656 estimates that the proposed rule, when viewed in
conjunction with the entire body of new regulatory initiatives on the utility fleet, will impact roughly
400,000 MW of oil- or coal-fired generation, or 40% of the current available capacity in the U.S. This
commenter quotes NERC which predicts the rules could jeopardize 30 to 70 GW of generating capacity
by 2015. Commenter 17834 predicts the early closure of many facilities as a result of the proposed rule
and reports that these EGUs play a central role in a region's economy since they are a source of jobs and

576


-------
contribute to the tax base. Commenter 17868 believes that the EPA has grossly underestimated the
number of coal-fired generation retirements at only 9.9 GW, which is only 3% of all coal-fired capacity
by the year 2015. The commenter believes that the EPA chose to view the proposed EGU NESHAP in
isolation and not in the CSPAR (the replacement of the Regional Transport Rule). Many published
studies project retirements above 40 GW, when viewed in combination and under certain circumstances.

Commenter 18023 also quotes the NERC report and discusses the resulting problems from the predicted
shut downs, which include adverse impacts of displacing coal-fired generation with other forms that do
not provide the same kinds of grid support functionality, increased interconnection of variable energy
sources such as solar and wind. The problem of grid operators being unable to know the locations and
parameters of generator locations in enough time to facilitate transmission facilities is also mentioned,
and Commenter 18023 requests a thorough reliability analysis given the compliance framework and
timeline of the proposed rule.

Response to Comment 98: The agency prepared a resource adequacy analysis for the proposed rule and
has revised that analysis for the final rule. The agency is working with FERC regarding the reliability
impacts of this rule. The EPA estimates 4.7 GW of capacity will retire early as a result of this rule. We
have not prepared a cumulative impacts analysis for the various power sector rules that have been
finalized or are in process of being finalized because the agency does not believe such an analysis would
be as accurate and transparent as analyses for each of these individual rules. The EPA has outlined the
various flexibilities associated with the rule, and the approaches to reliability issues in the preamble.

Comment 99: Commenter 17648 discusses the economic factors behind EGU retirements. These factors
include the cost of alternative generation using natural gas, the cost of implementing demand response
measures that can be bid into capacity markets, and the cost of continuing to generate power from an
existing unit. The commenter states that regardless of the costs associated with the Toxics Rule and
other EPA electric power industry regulations, some power plants were already economically
unsustainable. The commenter quotes M.J. Bradley, who points out, "Of the 122 coal units in PJM with
capacity less than or equal to 200 MW, 35 failed to recover their avoidable costs and another 52 were
close to not recovering those costs. Therefore, in PJM ... in addition to approximately 10 GW of coal
generation that has or will be retired during the seven years from 2004 to 2011, another 11 GW faces a
troubling economic outlook." The commenter provides confirmation of this by the most recent PJM
capacity auction, where approximately 6.9 fewer GW of coal-fired capacity cleared the auction (1.85
fewer GW were offered) as compared with the prior year's auction, and an additional 4.836 GW of new
demand response (energy efficiency) resources cleared the auction. Thus, the commenter states, some
claims linking retirements to the Toxics Rule are overstated and misleading. The commenter gives the
example of the American Electric Power attempt to link its planned plant closures to the Toxics Rule,
but those plants already are slated to either close or to upgrade controls to comply with existing laws.
The commenter goes on to quote three independent studies that support the finding that over 50% of the
fleet is equipped with scrubbers and the number will increase to nearly 2/3 by 2015. (Footnotes in
comment provide references to the studies and further quotes.)

Response to Comment 99: As discussed elsewhere in this document and in the preamble to this rule,
the EPA believes there will be modest levels of coal retirements, and many units slated for retirement
are being taken offline for other reasons aside from requirements to reduce emissions.

Comment 100: Commenters 17812 and 17736 believe the proposed rule will adversely affect the cost-
effective operation of industry energy operations and quote the U.S. Chamber of Commerce testimony
before Congress: "American Electric Power Co. made headlines last month when it disclosed that EPA's

577


-------
"train wreck: of coal regulations - Coal Ash, Utility MACT, the Transport Rule and Cooling Water
Intake Structures - would force the utility to retire 6,000 megawatts of coal-fired generating capacity
and spend another $6 billion to $8 billion reworking the rest of its fleet." AEP would close three power
plants in West Virginia, one in Ohio and one in Virginia, and would retire several boilers at coal plants
in Indiana, Kentucky, Ohio, Texas and Virginia.

AEP is not alone. Six other power plants have announced early retirement due to excessive regulation:
Portland Gas & Electric's Boardman coal-fired power plant in Oregon; Exelon Corporation's Oyster
Creek Nuclear Generating Station in New Jersey; TransAlta Corporation's Centralia coal-fired power
plant in Washington; and, just this week, three Georgia Power plants in the next 2 years. In each case,
the utility was forced to choose between installing several hundred million dollars' worth of pollution
controls to comply with the EPA regulations, or simply shut down early. In all cases, the utility chose
early retirement."

Commenter 17812 also expresses concern that increasing energy costs will reduce the ability of U.S.
industry to compete in the global marketplace, expand in the U.S., create jobs and increase contribution
to the GDP. The commenter quoted the 2010 EIA outlook which showed a 9.1% decline in industrial
electricity demand, the lowest since 1987.

Response to Comment 100: As discussed elsewhere in this document and in the preamble to this rule,
the EPA believes there will be modest levels of coal retirements, and many units slated for retirement
are being taken offline for other reasons aside from requirements to reduce emissions.

Comment 101: Several commenters (17682, 17813, 17904, 17930) mention the proposed rule's impact
on mining. Commenter 17682 mentions increasing energy costs for the U.S. mining industry resulting in
fewer projects and associated jobs, as well as increasing dependence on foreign mineral resources.
Commenters 17904 and 17930 see mining impacts being disproportionally large for lignite mines, which
are dependent on their co-located lignite-fired power plants. Commenters state that if the plant closes,
there is no market for the lignite and the mine will also close, displacing plant workers. These impacts
are largest in Texas, the largest coal consuming state and fifth largest coal producing state, as well as a
deregulated electricity market. Commenter 17904 points out that the Texas coal market provided a
buffer against natural gas price volatility and in particular believes the proposed rule does not take into
account the emission reductions already achieved by industry in general and their company in particular.
Commenter 17813 states that impacts will be magnified in Texas, since it is the largest coal consuming
state and mines lignite. Commenter 17813 also states it is unclear the extent to which the EPA includes
the impacts on the mining industry that will result from this rule.

Response to Comment 101: The agency presents impacts on the coal mining sector from this rule in the
RIA. Given the modest increase in coal and other energy costs associated with the rule, the agency does
not expect widespread impacts on coal mining. The agency's modeling accounts for all emission
controls and programs installed and/or implemented up through December 2010. The EPA analysis
indicates that there will be a small amount of coal retirements (less than 2% of all coal-fired capacity).
In addition, the EPA has conducted an updated employment analysis which shows some potential
positive and negative employment changes from the rule, but overall expects the employment impact to
be relatively small in comparison to the affected sector and the overall economy.

Comment 102: Commenter 18500 states that the EPA has justified the regulation of EGUs based, in
part, on the fact that such regulation will make the market for electricity more level and less skewed
toward polluting units. Although there is no legal basis to justify regulation on market parity, the EPA

578


-------
must recognize that by changing market dynamics in single clearing price markets, every incremental
increase in price applies to all electricity sold in that market, not just to the impacted unit. Given that
half of the American population lives in Regional Transmission Organizations (RTOs) where
incremental cost increases apply to all energy costs, this will be a significant factor. The EPA has failed
to account for the impact these rules will have on the total cost of energy across RTO markets where
every incremental increase in price applies to all electricity sold in that market, not just to the impacted
unit, while at the same time asserting beneficial market impacts.

Commenter 17868 asks that the EPA address the unproductive costs of compliance that occur due to
RTO market structures, since the rule is expected to lead to plant closures of plants dispatched to meet
demand. As a result, power generated by plants not facing greater compliance costs will still be sold at a
price reflecting the costs to other plants. This occurs because the highest offer accepted in an hour sets
the price for all megawatt-hours consumed, a single coal or natural gas plant can affect the prices paid
for by all the electricity generated by nuclear, hydropower, wind, and all other plants within that hour.
The commenter believes this market structure will lead to costs beyond that of compliance being passed
on to consumers and gives the following example: "in the most recent Reliability Pricing Model (or
RPM) auction, held in May 2011 to procure capacity for the June 2014 through May 2015 time period, a
number of plants added to their supply offers the costs associated with installation of emission control
technologies to meet environmental regulations. PJM estimated that these higher costs were responsible
for at least half of the 350% price increase between the past two auctions in the western region of PJM,
from $27.73 per MW/day to $125.99 per MW/day. Although the number of units or MWs that included
these compliance costs is not yet available, PJM's graphical representation shows that of the roughly
150,000 MW that cleared the auction and will receive this capacity price, about 120,000 MW offered to
sell capacity at a zero or close to zero price. (Zero price offers are typically submitted by existing base
load plants who are price takers in the auction.) Therefore the half of the $98 price increase attributable
to environmental upgrades will be paid to all 120,000 MWs of capacity that did not include
environmental compliance costs in their offers, equal to an unproductive cost of at least $2.1 billion for
just one year.. .These factual PJM auction results from May 2011 demonstrate that the U.S. EPA's
assertion that the electricity consumer will see no more than a 3.6% increase in the cost of electricity
does not match recent actual market performance. The U. S. Census reports that currently there are
307,006,550 people in the U.S. and approximately 51 million of them live in the PJM Market. This
means that approximately 15% of the U.S. population is affected by PJM Market" The commenter
provides figures showing how coal plant closures will impact different locations. (EPA-HQ-OAR-2009-
0234-17868-A2)

Response to Comment 102: The EPA provides regional estimates of the projected retail electricity
price impacts of the rule, and the impacts vary across regions for a variety of reasons (market structure
being one of them). In addition, the auction results cited are not a reflection of retail price impacts,
which will be dampened since the cost of generation is just one of several components of retail prices.
The auction also resulted in significant new capacity and additional demand-side resources, which show
that there are multiple avenues for how utilities can respond to the requirements of this rule. The auction
also indicates that there will be adequate reserve margin. The most important point that the commenter
ignores is the baseline. The EPA assesses the impacts of its rules not in relation to what is happening
today or from the 2013/2014 PJM auction, but in relation to what would have happened in the absence
of this rule in the same year (in 2015 for MATS). The commenter is unable to fully ascertain, based on
the analysis presented, the incremental effect of the rule alone and is lumping in other important
industry trends and dynamics that will impact future prices. The EPA has updated its analysis of price
impacts of MATS, which are presented in the RIA on a regional and nationwide basis.

579


-------
Comment 103: Commenter 18497 explains that the EPA's retirement estimate is very low and cites
several studies of regional retirements. The commenter reports that in the East North Central U.S.

Census Region alone (includes the states of Indiana, Illinois, Michigan, Ohio, and Wisconsin), ICF
identified 25 GW of at-risk capacity- more than in all other census regions combined and over two times
the next most impacted region (East South Central - 11 GW). The Brattle Group analysis estimated 50-
65 GW of coal-unit retirements nationwide by 2020 based on the need to install scrubbers and SCR
controls. Of that total, 12-15 GW were located in the Midwest Independent Transmission System
Operator (MISO) regional transmission organization (RTO), and 8-15 GW were located in the PJM
Interconnection (PJM). The commenter references the DOE deputy assistant secretary for clean coal,
James F. Wood who states, "Number one, electric rates are going to go up. Number two, whether or not
construction jobs in the green industry are created, I think there's [sic] virtually no manufacturing jobs
that are likely to be created from the replacement of coal. Three ... transmission grid stability is likely to
emerge as a major issue, both because of the shutdowns and because of the intermittency of
renewables." He also pointed out the sizable impact shutting down one power plant could have on the
local community. The commenter also quotes the Credit Suisse analyses showing around 60 GW of coal
closed in 2013-2017 and 100 GW requiring large investments to comply at a cost of $70-100 billion to
cover compliance or replacement expenses. The commenter also quoted the Berstein report which
projected 54 GW of coal retirements and a 1.2 Tcf increase in annual natural gas demand, leading to
increased prices as much as $92/MW a day.

Response to Comment 103: The EPA analysis indicates that there will be a small amount of coal
retirements (less than 2% of all coal-fired capacity) as a result of this rule. Most studies use flawed
assumptions and do not fully reflect the rule, including some important areas of flexibility. The analyses
also conflate other issues, like natural gas prices and low electricity demand, and do not isolate the effect
of this rule separately. The EPA believes there will be modest levels of coal retirements, and many units
slated for retirement are being taken offline for other reasons aside from requirements to reduce
emissions. The impact of the rule will vary across regions, and the EPA has presented some of those
impacts in the RIA. Overall, coal-fired generation is not expected to change significantly since sources
are anticipated to install pollution controls. The EPA will work with relevant authorities to ensure a
smooth transition with this rule and address specific issues. Public utility commissions and other
regulatory authorities have extensive experience with regulatory requirements and treatment of costs to
consumers, and are prepared for responding to the cost of future pollution control equipment or other
response measures. In addition, the EPA has conducted an updated employment analysis which shows
some potential positive and negative employment changes from the rule, but overall expects the
employment impact to be relatively small in comparison to the affected sector and the overall economy.

Comment 104: Commenter 16469 states that the coal units more likely to retire due to the proposed rule
are over 40 years old, under 400 MW and are cycling or "load-following" units for which the costs
associated with additional controls would be too high for the infrequently run units to recoup. The
commenter expects combined cycle natural gas units to pick up the share of generation for these units.

Response to Comment 104: The EPA agrees with the commenter.

Comment 105: Commenter 17881 explains the process by which the regulated utility created a Strategic
Plan with the state and the EPA which commits them to a $1.6 billion upgrade through the year 2018.
The commenter reports that they now find themselves in a position where they will need to retire a
significant percentage of their coal-fired fleet in response to the proposed rule.

580


-------
Response to Comment 105: Industry has shown that it can install large amounts of pollution controls
and often finds more cost-effective compliance options than the EPA can anticipate. In addition, the
EPA has analyzed resource adequacy issues and finds that there is ample existing spare capacity to serve
load, and industry has also shown that it can build new capacity quickly in response to demand. The
EPA will work with relevant authorities to ensure a smooth transition with this rule. In addition, there
are certain provisions for granting utilities some additional time to comply, if conditions warrant (see
preamble).

Comment 106: Commenter 16849 reports that they plan to convert a Riverton, Kansas plant to use
natural gas, rather than retiring it, as predicted in the "IPM Parsed Results Policy Case."

Response to Comment 106: The EPA modeling and projections are intended to be a reflection of
possible compliance using specific tools, assumptions, and methodologies that the agency believes to
reflect the best and most current information related to the power sector. It is not intended to reflect
actual compliance decisions, since those will be made individually by the affected industry based on
what makes the most sense to them using existing technologies or other, more cost-effective strategies.

Comment 107: Commenter 17403 believes the EPA has not adequately assessed the costs associated
with the retirement of smaller units, just as job losses and employment shifts as workers are retrained
and re-employed elsewhere.

Response to Comment 107: The EPA has conducted an updated employment analysis which shows
some potential positive and negative employment changes from the rule, but overall expects the
employment impact to be relatively small in comparison to the affected sector and the overall economy.

Comment 108: Commenters 17901 and 19742 believe the proposed rule and other federal rulemakings
will force the premature shutdown of many coal-fired power units, resulting in the loss of thousands of
jobs in utilities, coal, manufacturing and transportation. Commenter 17901 notes that states such as Ohio
that rely on eastern bituminous coal will be especially hard-hit.

Response to Comment 108: The EPA analysis indicates that there will be a small amount of coal
retirements (less than 2% of all coal-fired capacity) resulting from this rule and coal-fired generation
will not change significantly. The EPA questions whether any units will be retired "prematurely," noting
that any retirements likely to result from the rule will be of the oldest units that owners find least
economically viable to control. In addition, the EPA has conducted an updated employment analysis
which shows some potential positive and negative employment changes from the rule, but overall
expects the employment impact to be relatively small in comparison to the affected sector and the
overall economy.

Comment 109: Commenter 17931 disagrees with the EPA's conclusion that few coal-fired units will
retire in response to the proposed rule because they state that DSI use will not provide the expected
compliance.

Response to Comment 109: There are many compliance options, and each affected source will choose
the most effective strategy to meet the requirements of the rule. The EPA is not prescribing particular
technologies, and industry has a successful track record of responding to air reduction programs through
innovation, often a cost much less than what the EPA originally anticipated.

581


-------
Comment 110: Commenter 16850 notes that significant controls would be necessary at many of
Florida's coal- and oil-fired generating units, and some units would be at risk of retirement.

Commenter 16850 states that the EPA's final rules should avoid compromising electric system
reliability and allow the maximum compliance flexibility for electric utilities provided for under the
Clean Air Act.

Response to Comment 110: As stated above, there are many compliance options, and each affected
source will choose the most effective strategy to meet the requirements of the rule. The agency prepared
a resource adequacy analysis for the proposed rule and has revised that analysis for the final rule. The
agency is working with FERC regarding the reliability impacts of this rule. The EPA has outlined the
various flexibilities associated with the rule, and the approaches to reliability issues in the preamble. In
addition, there are certain provisions for granting utilities some additional time to comply, if conditions
warrant (see preamble).

Comment 111: Commenter 18016 predicts an 8% decrease in coal production in Alabama as a result of
the proposed rule, exacerbating economic problems there. Another concern to the commenter is the cost
increases and capacity shortfalls resulting from the expedited shutdown of tens of thousands of
megawatts of existing coal-fired generating capacity.

Response to Comment 111: The EPA analysis indicates that there will be a small amount of coal
retirements (less than 2% of all coal-fired capacity) and coal-fired generation will not change
significantly. The agency has also assessed resource adequacy, and has determined that there is
sufficient excess capacity in existence that will help serve load. In addition, the EPA has conducted an
updated employment analysis which shows some potential positive and negative employment changes
from the rule, but overall expects the employment impact to be relatively small in comparison to the
affected sector and the overall economy. In addition, there are certain provisions for granting utilities
some additional time to comply, if conditions warrant (see preamble).

Comment 112: Commenter 18424 states that according to a study by UJAE, more than 60% of coal
shipments in Indiana would not be able to comply with that limit when burned in units controlled by
scrubbers operating at 95% SO2 removal efficiency. If sources cannot comply with the proposed limits
using bituminous coals, they will not use those fuels or they will retire the units.

Response to Comment 112: : The EPA disagrees with the comment. Since scrubbers effectively
capture acid gas HAP more efficiently than SO2, units equipped with this control device operating at
95% S02 removal efficiency are expected to suffice.72 For those scrubbers operating below 95% S02
capture, controls upgrades are available to improve performance.73 Potential impacts to coal supply are
discussed in the preamble for the final rule and in the RIA.

Comment 113: Commenter 17852 asserts that the proposed rule can and should promote the orderly
retirement of old, high-emitting power plants. It is widely recognized that the current fleet of coal-fired
power plants includes many old, uncontrolled, inefficient units that lack up-to-date and effective
controls for hazardous emissions. Many of these units are slated to retire. In fact, over 20 GW of coal-
fired generation have been recently announced for retirement. However, current regulatory provisions do
not always sufficiently promote utility planning for these retirements, causing some in the utility sector

72	Assessment of Technology Options Available to Achieve Reductions of Hazardous Air Pollutants" by
Lipinski, Leonard, Richardson; published by URS; April 5, 2011

73	Ibid.

582


-------
to delay action and then raise concerns regarding perceived threats to electric system reliability that
would not otherwise exist if more advance planning had been done. In the proposed rule, the EPA
recognized that "Although most RTOs/ISOs only require 90-day notifications for retirements,
construction schedules for all but the simplest retrofits will be longer, so sources should be able to notify
their RTOs of their retirements earlier." To provide an incentive for early planning, the EPA said that it
"encourages state environmental regulators to consider the extent to which a utility engages in early
planning when making a decision regarding granting a 4th year for compliance" with the Utility MACT.
The commenter supports the EPA's approach of encouraging utilities to engage in early planning and to
timely announce the retirements of the oldest and highest-emitting power plants in the fleet.

Notifications of only 90 days are clearly inadequate, and waiting so long maximizes the chance that
reliability issues may occur, rather than minimizing it.

Response to Comment 113: The purpose of today's rule is to establish standards to reduce emissions of
harmful pollutants in compliance with the requirements of the CAA, not to retire any particular power
plants. The EPA continues to encourage utilities to engage in early planning when considering how to
respond to the new regulations - whether to comply or to retire the EGU - and appreciates the
commenter's support.

4. Flexible regulations.

Comment 114: Several commenters (17004, 17022, 17026, 17028) consider the purchase of electricity
to be a major cost of doing business and question the wisdom of imposing a higher cost on businesses
through regulatory inflexibility or needlessly short deadlines. These commenters, along with commenter
17887, urge the EPA to consider developing energy policies that will allow businesses to expand and
generate jobs by deferring or mitigating price increases through adopting more flexible regulations.

Response to Comment 114: The agency recognizes that electricity cost can be an important cost of
doing business for many manufacturers. As such, it has attempted to provide the greatest degree of
flexibility permitted by law. However, the agency is under a court-ordered deadline reflected in a
Consent Decree that requires that a MACT standard be issued, and EPA is also making revisions to the
current NSPS. Implementation deadlines in the final rule are in response to the underlying requirements
of the CAA, and any flexibility that the agency can offer must be consistent with the CAA.

Comment 115: Commenter 17692 expresses concern that the proposed rule will increase electricity
costs in Louisiana, where businesses depend on adequate and affordable electricity and domestic
productivity could be depressed. The commenter believes the impacts of the proposed rule could be
much less if the EPA were less strident and more flexible in the rule requirements.

Response to Comment 115: The agency's analysis finds that the national average retail electricity price
increase is expected to be 3.1% in 2015. This increase should be understood in the light of the extensive
benefits from HAP and non-HAP emission reductions expected from this rule. The EPA has attempted
to provide the greatest degree of flexibility permitted by law.

Comment 116: Several commenters (17707, 17824, 18419) state that Alabama uses coal to supply
nearly 60% of electricity needs and employs 1500 workers to run the coal-fired power plants.
Commenters worry the proposed rule will jeopardize efforts to increase economic growth and job
opportunities in the state. The commenter urges the EPA to adopt more flexible standards and timelines
to achieve affordable utility bills, stable jobs and reliable power. Commenters 17824 and 18419 state
that Alabama Power has spent $2.6 billion to install technologies to reduce emissions from coal-fired

583


-------
units and succeeded in dropping NOx and SO2 emissions by 65% since 1996. Commenters consider the
proposed rule to be unreasonable and unfounded, with the cost vastly outweighing the benefits.

Response to Comment 116: The agency's analysis shows that the national average retail electricity
price is projected to increase by 3.1% in 2015. The EPA has attempted to provide the greatest degree of
flexibility permitted by law. The EPA analysis indicates that there will be a small amount of coal
retirements (less than 2% of all coal-fired capacity) and coal-fired generation will not change
significantly. The agency has also assessed resource adequacy, and has determined that there is
sufficient excess capacity in existence that will help serve load. In addition, the EPA has conducted an
updated employment analysis which shows some potential positive and negative employment changes
from the rule, but overall expects the employment impact to be relatively small in comparison to the
affected sector and the overall economy. In addition, there are certain provisions for granting utilities
some additional time to comply, if conditions warrant (see preamble).

Comment 117: Commenter 17648 observes that "the positive economic impacts of the proposed Toxics
Rule strongly militate in favor of its adoption. Contrary to the unfounded assertions by critics of the
EPA and the rule, the EPA has conducted a technically sound and conservative benefit-cost analysis
showing that the proposed rule's benefits are at least five times as high as its costs. With sound, albeit
unduly conservative, econometric modeling, the EPA has also determined that the Toxics Rule will
promote economic growth and create jobs in both the long and short term." This commenter and
commenter 18432 cite the EPA impact analyses by Dr. Charles Cicchetti which confirms this finding
and state that the analysis underestimates the Rule's net benefits and positive impacts on the nation's
economy. By considering some benefits not monetized in the EPA analysis, Dr. Cicchetti concludes that
the proposed rule will create $52.5 to $139.5 billion in net benefits annually, create 115,200 jobs,
generate annual health savings of $4,513 billion, annual increases in GDP of $7.17 billion and $2,689
billion in additional annual tax revenues, and spur innovation and modernization of EGUs. The
commenter states that the study findings show no need to delay implementation of the rule or needlessly
duplicate economic analyses already completed.

Comment 118: Commenter 17648 reports that multiple researchers confirmed that the EPA's estimates
of economic stimulus are conservative and that the proposed rule will stimulate job growth. The
commenter quotes Dr. Josh Bivens of the Economic Policy Institute, who also found that EPA's
conclusions were conservative. Dr. Bivens concluded, "The EPA RIA on the proposed toxics rule makes
a compelling case that the rule passes any reasonable cost-benefit analysis with flying colors—the
monetized benefits of longer lives, better health, and greater productivity dwarf the projected costs of
compliance. . . . Whether regulation in general and the toxics rule in particular costs jobs is an empirical
question this paper attempts to answer. In particular, this paper examines the possible channels through
which the proposed toxics rule could affect employment in the United States and finds that claims that
this regulation destroys jobs are flat wrong: The jobs-impact of the rule will be modest, but it will be
positive." His report details the following major findings:

1.	The proposed rule would have a modest positive net impact on overall employment, likely leading to
the creation of 28,000 to 158,000 jobs between now and 2015.

2.	The employment effect of the [Toxics Rule] on the utility industry itself could range from 17,000
jobs lost to 35,000 jobs gained.

3.	The proposed rule would create between 81,000 and 101,000 jobs in the pollution abatement and
control industry (which includes suppliers such as steelmakers).

4.	Between 31,000 and 46,000 jobs would be lost due to higher energy prices leading to reductions in
output.

584


-------
5. Assuming a re-spending multiplier of 0.5, and since the net impact of the above impacts is positive,
another 9,000 to 53,000 jobs would be created through re-spending.

Commenters 17648 and 18961 also provide information from The University of Massachusetts Political
Economy Research Institute, which prepared a February 2011 study of the jobs impacts of the proposed
rule and the Transport rule. Based on estimates that the power sector will invest almost $200 billion total
in capital improvements between 2010 and 2015 in these 36 states, the researchers found that the total
employment created by these capital investments is estimated at 1.46 million jobs, or about 290,000 jobs
on average in each of those years.

Response to Comments 117 and 118: The EPA has conducted an updated employment analysis using
the approach applied for the proposed rule which shows some potential positive and negative
employment changes from the rule, but overall expects the employment impact to be relatively small in
comparison to the affected sector and the overall economy. It should be noted that the agency's
employment impact analysis is focused on short-term estimates of impacts from installation and
operation of new pollution control equipment, and long-term estimates of impacts for the regulated
industry (electric power generation). Our rationale for the analysis and the analysis itself are in the RIA
for the rule.

Comment 119: Commenter 18419 asks the EPA to perform a true economic analysis, evaluate the
proposed rule with other new and pending regulations and provide more flexible standards and
reasonable compliance guidelines.

Response to Comment 119: The EPA has attempted to provide the greatest degree of flexibility in the
rule that is permitted by law.The agency's economic analysis is consistent with the guidelines provided
by OMB for rules such as this one that are economically significant under EO 12866, an Executive
Order issued by OMB in 1993. The agency did not prepare a cumulative impact analysis to accompany
the rule for the following reasons: 1) the various EO requirements that the agency must comply with
require us to estimate impacts specific to this rule; 2) decision makers and the public need to know the
impacts specific to a particular rule in order to judge the merits of the regulation; 3) estimates specific to
a particular rule are more transparent than those from a cumulative impact analysis. A cumulative
impact analysis lumps several regulations together and can potentially mask a high-cost/low-benefit
regulation among other rules that may have large net benefits. By analyzing each regulation separately,
the EPA makes clear statements about what impacts, costs, and benefits will be generated as a result of
this particular regulation.

This does not, however, mean EPA has failed to consider cumulative impacts of the regulation. The
inclusion of CSAPR and other regulatory actions (including federal, state, and local actions) in the IPM
base case reflects the level of controls that are likely to be in place in response to other requirements
apart from MATS. This base case provides meaningful projections of how the power sector will respond
to the cumulative regulatory requirements for air emissions, while isolating the incremental impacts of
MATS. These results are presented in Chapter 3 of the RIA.

Additionally, the Agency does reflect on the broader cumulative impacts of our regulations. In March
2011, EPA issued the Second Clean Air Act Prospective Report which assessed at the benefits and costs
of regulations pursuant to the 1990 Clean Air Act Amendments. The study examines the cumulative
impact of these regulations (found at http://www.epa.gov/air/sect812/febl 1/summaryreport.pdf). As
shown in the report, the direct benefits from the 1990 Clean Air Act Amendments reach almost $2
trillion for the year 2020, a figure that dwarfs the direct costs of implementation ($65 billion). The full
report is at http://www.epa.gov/air/sect812/prospective2.html.

585


-------
The direct benefits of the 1990 Clean Air Act Amendments and associated programs significantly
exceed their direct costs, which means economic welfare and quality of life for Americans were
improved by passage of the 1990 Amendments. The wide margin by which benefits exceed costs
combined with extensive uncertainty analysis suggest it is very unlikely this result would be reversed
using any reasonable alternative assumptions or methods. This conclusion is likely to also be attributable
to this rule as shown in the RIA.

5. Job analysis: temporary versus permanent jobs.

Comment 120: Commenters 17811 and 18436 believe that installation of new pollution controls would
be a job-growth opportunity in Alabama because money spent on controls for power plants creates high-
quality jobs in steel, cement and other materials, as well as in the assembling of the equipment as well as
installing and operating it. Commenter 18436 shares the Alabama Fisheries Association estimate that the
water-based recreation industry brings in over $1 billion per year to the state's economy though the state
ranks third for imperiled fish with 61 bodies of water cited for Hg contamination. The commenter
believes the HAP accumulating in the waterways threaten the industry with permanent job-losses and
lost revenue.

Response to Comment 120: The EPA finds commenters' economic predictions and statements of
benefits to be reasonable. The EPA has conducted an updated employment analysis which shows some
potential positive and negative employment changes from the rule, but overall expects the employment
impact to be relatively small in comparison to the affected sector and the overall economy.

Comment 121: Commenters 17834 and 18033 disagree with the EPA speculation that job losses will be
offset by increasing jobs in air pollution technology production. Commenters believe the proposed rule
will decrease job creation and sees no assurance or conclusive data that jobs will be created.

Commenters go on to request that the EPA withdraw the proposed rule, citing an unstable regulatory
climate and unclear economic impacts. Commenter 18033 quotes economist David Montgomery's
testimony before Congress in which he said that "Claims that regulations that raise the cost of doing
business will create new jobs are, at best, a sideshow. Such claims only distract attention from the
difficult tradeoffs that must be made between costs and benefits. "Green jobs" is not a subject that
leading economists have usually taken seriously enough in professional journals. Based on the
foregoing, it is difficult for EPA to legitimately claim that the proposed rule's benefits analysis is
accurate."

Response to Comment 121: The EPA does not have the flexibility to withdraw or delay the rule, which
is governed by a consent decree and the requirements of the CAA. The EPA has conducted an updated
employment analysis which shows some potential positive and negative employment changes from the
rule, but overall expects the employment impact to be relatively small in comparison to the affected
sector and the overall economy. All of these analyses are found in the RIAs for the respective rules.

Comment 122: Commenter 17930 disagrees with the EPA's prediction of an annual cost of $10.9
billion by 2015 and estimates it to be up to $100 billion annually. The commenter also disagrees with
the EPA prediction of new jobs created, because the commenter believes far more plants will shut down
than the EPA predicts, resulting in higher job losses. The commenter points out that while jobs running
power plants are permanent, the jobs predicted to be created by the proposed rule are short term
construction jobs, and will all occur in the same short timeframe for compliance. Further, the commenter
states that the EPA estimate does not include the opportunity cost of lost construction jobs due to new
power plants that will not be constructed due to the proposed rules.

586


-------
Response to Comment 122: The EPA has conducted extensive analysis of the rule, which can be found
in the RIA. The cost analysis by the agency is based on a peer-reviewed power sector model that has
been used in multiple rulemakings affecting the electric power sector over the past 15 years. The EPA
has also conducted an updated employment analysis which shows some potential positive and negative
employment changes from the rule, but overall expects the employment impact to be relatively small in
comparison to the affected sector and the overall economy. Overall impact on retail electricity prices
nationwide is also anticipated to be modest in light of the significant benefits of the rule. The EPA
cannot evaluate the basis for commenter's claim of higher impacts, but on the basis of its own detailed
analysis does not find it to be reasonable.

Comment 123: Commenter 17761 questions the EPA estimate that the proposed rule will create jobs.
The commenter points out that coal-fired plant closures will lead to the loss of more jobs than the
creation of gas-fired units will create because coal-fired plants employ 75-100 people versus 25-30 for a
gas plant of equivalent size.

Response to Comment 123: The EPA has conducted an updated employment analysis which shows
some potential positive and negative employment changes from the rule, but overall expects the
employment impact to be relatively small in comparison to the affected sector and the overall economy.
The commenter points to only one potential change in employment, that of a transition from coal to
natural gas-fired generation, but does not address other changes, such as jobs created by increases in
production of pollution control equipment.

Comment 124: Commenter 17903 agrees with the EPA's job creation estimations for the proposed rule
and reports that 20,000 of the new jobs are expected to be in Iowa. The commenter also mentions that
utility boards must approve rate increases, and these may not be given at all or will help to control the
rate increases claimed by industry.

Response to Comment 124: The EPA has conducted an updated employment analysis which shows
some potential positive and negative employment changes from the rule, but overall expects the
employment impact to be relatively small in comparison to the affected sector and the overall economy.
The EPA will work with relevant authorities to ensure a smooth transition with this rule and address
specific issues. Public utility commissions and other regulatory authorities have extensive experience
with regulatory requirements and treatment of costs to consumers, and are prepared for responding to the
cost of future pollution control equipment or other response measures.

Comment 125: Commenter 19121 says that the EPA appears to have overstated the job creation
estimates due to economic growth under the proposed rule.

Response to Comment 125: The EPA has conducted an updated employment analysis which shows
some potential positive and negative employment changes from the rule, but overall expects the
employment impact to be relatively small in comparison to the affected sector and the overall economy.

Comment 126: Commenters 16469 and 18500 estimate the potential job losses associated with the
closure of coal units could amount to more than 50,000 direct jobs in the coal, utility and rail industries,
with a total job loss including indirect jobs of 251,300. Commenters note that the EPA's analysis did not
estimate the effects of adverse employment or effects of higher electric rates. Commenter 16469
provides a table (see EPA-HQ-OAR-2009-0234-16469-Al_Table page 15) summarizing estimated
direct job losses in the utility, coal and rail sectors by region based on the 2005 electric generation of
affected units. Indirect job losses are estimated using Department of Commerce RIMS II multiplier data

587


-------
for the electric, gas and water utility industries, specific to each state and do not account for short-term
or permanent job gains from control unit construction and operation. The commenter provides a
preliminary assessment of coal "units at risk" on which these related potential job losses are based. The
assessment is contained in Attachment 4 (see EPA-HQ-OAR-2009-0234-16469-A1), based on data
sorted from the 2007 DOE/NETL Coal Plant Data Base, updated for information on recent scrubber
retrofits and retirements. The units included in the screening are more than 40 years old and between 25
MW and 400 MW, without installed or planned scrubbers. The 2005 generation from these units
provided a substantial share of total electric generation in several regions (using a 2009 state generation
baseline): 18% in the East North Central region, 14% in the West North Central, and 12% in the South
Atlantic. In several states, these units supplied 20% or more of total generation.

Response to Comment 126: The EPA analysis indicates that there will be a small amount of coal
retirements (less than 2% of all coal-fired capacity) and coal-fired generation will not change
significantly. The agency has also assessed resource adequacy, and has determined that there is
sufficient excess capacity in existence that will help serve load. The EPA has also conducted an updated
employment analysis which shows some potential positive and negative employment changes from the
rule, but overall expects the employment impact to be relatively small in comparison to the affected
sector and the overall economy. Overall impact on retail electricity prices nationwide is also anticipated
to be modest in light of the significant benefits of the rule.

Comment 127: Commenters 17254 and 17409 quote IBEW president Edwin Hill and United Mine
Workers of America who both state that as many as 50,000 workers in the utility, mining and railroad
industries could lose their jobs in response to the proposed rule. Commenters disagree with the EPA's
estimate of short and long-term job growth, believing that the permanent job losses are underestimated
and quotes the HIS Global Insight estimate that for every billion dollars spend on compliance with the
proposed rule, 16,000 jobs will be at risk and the U.S. GDP will be reduced by as much as $1.2 billion.
Commenters ask that the EPA's analysis account for the loss of tax and support for local schools due to
job losses.

Response to Comment 127: The EPA analysis indicates that there will be a small amount of coal
retirements (less than 2% of all coal-fired capacity) and coal-fired generation will not change
significantly. The agency has also assessed resource adequacy, and has determined that there is
sufficient excess capacity in existence that will help serve load. The EPA has also conducted an updated
employment analysis which shows some potential positive and negative employment changes from the
rule, but overall expects the employment impact to be relatively small in comparison to the affected
sector and the overall economy. Overall impact on retail electricity prices nationwide is also anticipated
to be modest in light of the significant benefits of the rule.

Comment 128: Commenter 17409 quotes estimates by ICF International that employment income is
estimated to drop in response to the proposed rule by about 2 or 2.5 million full-time workers due to
retail electricity price increases.

Response to Comment 128: The EPA has conducted an updated employment analysis which shows
some potential positive and negative employment changes from the rule, but overall expects the
employment impact to be relatively small in comparison to the affected sector and the overall economy.
The EPA cannot evaluate the basis for ICF International's projections, but believes that its own analysis
is as accurate, transparent, and well-supported.

588


-------
Comment 129: Commenter 17839 states that the transition to clean, renewable energy will create many
more jobs than may be lost due to the proposed rule and questions if jobs will actually be lost at all.

Response to Comment 129: The EPA agrees that this can be one source of new employment resulting
from today's rule. It has conducted an updated employment analysis which shows some potential
positive and negative employment changes from the rule, but overall expects the employment impact to
be relatively small in comparison to the affected sector and the overall economy.

Comment 130: Commenter 17767 reports that their organization could lose 30 jobs as a result of
complying with the proposed rule, and the reduced need for coal could put those employed by coal
mines or trucking companies out of work as well.

Response to Comment 130: The EPA analysis indicates that coal-fired generation will not change
significantly. The EPA has conducted an updated employment analysis which shows some potential
positive and negative employment changes from the rule, but overall expects the employment impact to
be relatively small in comparison to the affected sector and the overall economy.

Comment 131: Multiple commenters (17811, 18421, 18436) agree with the EPA's projections that the
proposed rule will lead to the creation of 31,000 short-term construction jobs and 9,000 long-term utility
jobs. The commenter also quotes the World Resources Institute, which announced that compared to
overall spending in the economy, spending on environmental protection and clean-up employs more
than twice as many workers in construction and 25% more in manufacturing.

Response to Comment 131: The EPA generally agrees with the thrust of commenters' assertions and
those of the World Resources Institute. The EPA has conducted an updated employment analysis which
shows some potential positive and negative employment changes from the rule, but overall expects the
employment impact to be relatively small in comparison to the affected sector and the overall economy.

Comment 132: Commenter 17813 disagrees with the EPA's estimate of created jobs because the
commenter expects retirements to be much higher than predicted, costing more jobs. The commenter
argues that the jobs the EPA categorizes as new cannot be compared to the permanent jobs lost, because
they will be temporary. The commenter also believes the EPA's assessment does not take into account
the lost opportunity of construction jobs that would have been created by constructing new power plants
that will not be built as a result of the proposed rule.

Response to Comment 132: The EPA disagrees and notes that its analysis indicates that there will be a
small amount of coal retirements (less than 2% of all coal-fired capacity) and coal-fired generation will
not change significantly. The EPA thus believes there will be modest levels of coal retirements resulting
from the rule, and many units slated for retirement are being taken offline for other reasons aside from
requirements to reduce emissions. Overall, coal-fired generation is not expected to change significantly
since sources are anticipated to install pollution controls. The EPA has conducted an updated
employment analysis which shows some potential positive and negative employment changes from the
rule, but overall expects the employment impact to be relatively small in comparison to the affected
sector and the overall economy.

6. Natural gas.

Comment 133: Numerous commenters (17403, 17639, 17640, 17797, 17799, 17806, 17829, 17919,
18488, 18023) point out that the compliance dates underestimate the time needed to comply with the

589


-------
requirements and will lead to more coal-fired plant retirements and an increased demand for natural gas,
which will lead to fluctuations in natural gas prices. Commenter 17806 specifically states that the
compressed timeframe will make it virtually impossible to achieve compliance and significantly increase
the cost of power in most regions as well as threaten reliability. Commenter 17919 agrees with the other
commenters and cites the NERA Economic Consulting study done in May 2011 that projected average
U.S. retail electricity prices in 2016 to increase by 12%, with regional increases up to 24%, with a 13%
reduction in coal-fired generation and a 10% decline in electric sector coal demand in 2016. Also,

Illinois Power Agency estimates that by 2017 energy bills could jump 65% from current levels.
Commenter 18023 refers to the EEI report showing that over 150 GWs of coal units, approximately half
of the U.S. coal fleet, is at risk of being unavailable in 2015 due to insufficient time to achieve
compliance. This commenter points out that the timeframe strains the supply of equipment and related
resources, which increases costs that are passed on to consumers. A footnote offers and estimated
electricity price increase of up to 25% in the Southeast.

Response to Comment 133: The agency has prepared analyses of the costs, benefits, and employment
impacts associated with the rule and included them in the RIA for the rule. The projected impact on
national retail electricity prices is anticipated to be relatively small, and no region of the country is
expected to experience a double-digit increase in retail electricity prices as a result of this rule. Although
economically vulnerable families could experience some increase in electricity price in 2015, this
increase should be understood in the context of the substantial health benefits from Hg, HAP, and
reductions of other pollutants that will result. Industry has shown that it can install large amounts of
pollution controls and often finds more cost-effective compliance options than the EPA can anticipate.
In addition, the EPA has analyzed resource adequacy issues and finds that there is ample existing spare
capacity to serve load, and industry has also shown that it can build new capacity quickly in response to
demand. The EPA will work with relevant authorities to ensure a smooth transition with this rule. In
addition, there are certain provisions for granting utilities some additional time to comply, if conditions
warrant (see preamble). Natural gas supplies and reserves have increased significantly in recent years,
and prices have remained fairly stable since their peak in the early 2000s.

Comment 134: Commenter 17852 states that natural gas prices are not more volatile than for other
comparable commodities. Though not strictly part of the EPA's "beyond the floor" analysis, the EPA's
RIA also creates a misimpression by stating that "The natural gas market in the United States has
historically experienced significant price volatility from year to year, between seasons within a year, and
can even undergo major price swings during short-lived weather events." Simply put, natural gas prices
today are not inherently more volatile than other comparable commodities, and the U.S. - given the
abundance of natural gas - is likely to experience significantly less volatility than in the past. The
commenter and the Bipartisan Policy Center have jointly commissioned an entire report that
demonstrates why natural gas price volatility occurred in the prior decades (including due to the federal
government discouraging production), and why these concerns are less likely to occur in the foreseeable
future. These reasons include: an enhanced resource base due to shale gas, improved drilling technology,
improved storage and delivery infrastructure, and the elimination of government price control that
artificially constrained production. Furthermore, coal prices have experienced similar volatility in the
past, and have been widely reported to be facing upward price pressure due to the export of coal to meet
Asian demand.

Response to Comment 134: The EPA's analysis and conclusions concerning natural gas were not
intended to suggest abnormal volatility relative to other commodities, but only to acknowledge the
volatility that has been observed historically. The reasons given by commenters for expecting less

590


-------
natural gas price volatility in the future are not unreasonable, however, nor are observations about
increasing coal demand elsewhere.

Comment 135: Commenter 17725 states that natural gas use is only an option in places where
infrastructure exists to supply sufficient natural gas to the EGU and other local needs and reports that
year-round reliable gas delivery is rare due to requirements to meet the other needs. The commenter says
that gas interruptions are prevalent in the winter, but can happen year-round, and the costs of
establishing a natural gas line to a power plant can be tens of millions of dollars or more, and moving a
plant to a gas source can take many years. The commenter describes the options for a Norwalk Harbor
plant, and explains that the modifications are costly and difficult even before considering the
modifications needed to alter the boiler and fuel supply system to allow natural gas combustion.

Response to Comment 135: The EPA's analysis of the impacts to the power sector can be found in the
RIA of the rule. The agency has analyzed resource adequacy issues and finds that there is ample existing
spare capacity to serve load, and industry has also shown that it can build new capacity quickly in
response to demand. For example, the power sector brought online over 140 GW of gas capacity from
2001 to 2003. The EPA will work with relevant authorities to ensure a smooth transition with this rule.
In addition, there are certain provisions for granting utilities some additional time to comply, if
conditions warrant (see preamble). Natural gas supplies and reserves have increased significantly in
recent years, and prices have remained fairly stable since their peak in the early 2000s.

Comment 136: Commenter 17640 explains that a Midwest steel company estimates that a 1 cent per
kWh increase in electricity cost would add $10 million annually to company costs.

Response to Comment 136: The EPA has designed a rule with as much flexibility as possible and in
accordance with the requirements outlined in the CAA for HAP, and does not expect significant impacts
on electricity prices generally. The EPA believes energy efficiency measures can be a complement to
this rule, and can be an important tool in helping address emissions. The EPA has not included all the
likely additional energy efficiency measures that are likely to occur by 2015, but will continue to pursue
energy efficiency improvements throughout the economy, along with other Federal agencies, states and
other groups. This will contribute to additional environmental and public health improvements while
lowering the costs of realizing those improvements.

Comment 137: Multiple commenters (17403, 17812, 17868, 18500, 19211) disagree with the EPA
estimate for natural gas price changes. Commenter 17812 expects the proposed rule to lead to an
increase in natural gas prices as utility companies transition to burning natural gas instead of installing
emission controls. The commenters quote NERA estimates that natural gas prices will increase by 17%
in 2016, much higher than the EPA estimate of 0.6% to 1.3% increase. This translates to a natural gas
expenditure increase by residential, commercial and industrial sectors by $8.2 billion per year, or $85
billion (present value) for 2011-2030. Commenter 17868 agrees that prices will increase more than the
EPA estimates and asks that the EPA use a minimum set of natural gas prices such as the provided graph
of average national monthly gas prices provided (page 35 of EPA-HQ-OAR-2009-17868-A2).
Commenter 19211 sees the projected increase in natural gas prices as a reason manufacturers may lose
confidence in the U.S. as a favorable place to do business.

Response to Comment 137: The EPA has provided an assessment of the economic impacts of the rule
on the power sector, which can be found in the RIA of the rule. The agency has fully documented its
assumptions and framework for modeling natural gas in IPM for both the proposed and final MATS.

This information can be found in Chapter 10 of the IPM documentation

591


-------
(http://www.epa.gov/airmarkets/progsregs/epa-ipm/docs/v410/Chapterl0.pdf). The documentation
provides a thorough overview of the natural gas module, describes the very detailed process-engineering
model and data sources used to characterize North American conventional, unconventional, and frontier
natural gas resources and reserves and to derive all the cost components incurred in bringing natural gas
from the ground to the pipeline. Also documented are the resource constraints, liquefied natural gas
(LNG), demand side issues, the natural gas pipeline network and capacity, procedures used to capture
pipeline transportation costs, natural gas storage, oil and natural gas liquids (NGL) assumptions, and key
gas market parameters. IPM modeling of natural gas prices uses both short- and long-term price signals
to balance supply of and demand in competitive markets for the fuel across the modeled time horizon.
As such, it should be understood that the pattern of IPM natural gas price projections over time is not a
forecast of natural gas prices incurred by end-use consumers at any particular point in time. The natural
gas market in the U.S. has historically experienced significant price volatility from year to year, between
seasons within a year, and even sees major price swings during short-lived weather events (such as cold
snaps leading to short-run spikes in heating demand). These short-term price signals are fundamental for
allowing the market to successfully align immediate supply and demand needs; however, end-use
consumers are typically shielded from experiencing these rapid fluctuations in natural gas prices by
retail rate regulation and by hedging through longer-term fuel supply contracts. IPM assumes these
longer-term price arrangements take place "outside of the model" and on top of the "real-time" shorter-
term price variation necessary to align supply and demand. Therefore, the model's natural gas price
projections should not be mistaken for traditionally experienced consumer price impacts related to
natural gas, but a reflection of expected average price changes over the time period 2015 to 2030.

Comment 138: Commenter 17868 discusses the factors that could lead to higher natural gas prices not
currently reflected in the EPA impact projections, including industrial load and demand not rebounding
to 2008 levels and the influence of liquefied natural gas exports. The commenter asks that the EPA
address these factors:

1.	Higher natural gas demand for use in vehicles (a la The Pickens Plan) or some amount of
transportation electrification.

2.	Constraints either on shale resources allowed to be extracted due to regional opposition or reflect
drilling restrictions or a cost adder for environmental remediation.

3.	Starting oil prices "adapted from AEO 2009," of about $62/bbl for 2011 are well below current oil
prices.

4.	No documentation of any indication that the gas market module of IPM reflects the drilling lease
inventory buildup that may be causing some producers to drill at less economic prices in exchange
for cash flow and retention of their lease options.

5.	Unclear what the production per well or depletion assumptions are or whether they have been
updated (i.e., lowered) for the shift to more shale production.

6.	Figure 10-7 from U. S. EPA's proposed rule provides the resource cost curves but no documentation
of how they were derived or how the quantity able to be produced economically at prices below $14
per MMBtu was determined. Page 10-13 of U. S. EPA's proposed rule indicates that the
undiscovered gas resource is "assumed" to grow at 0.2% per year for conventional gas and 0.75%
for undiscovered gas. Nothing provides the basis for testing that assumption's validity. The
discussion admits that technology drives the ability to produce undiscovered resources but does not
test the technology assumption and no curves are provided at all for the existing discovered resource
base.

7.	The model covers North America only, so it must be fed an exogenous assumption on LNG imports
(or exports) and cannot predict or capture changes in world-wide development and trading of natural
gas.

592


-------
Response to Comment 138: The EPA has provided an assessment of the economic impacts of the rule
on the power sector, which can be found in the RIA of the rule. The agency has fully documented its
assumptions and framework for modeling natural gas in IPM for both the proposed and final MATS.

This information can be found in Chapter 10 of the IPM documentation

(http://www.epa.gov/airmarkets/progsregs/epa-ipm/docs/v410/Chapterl0.pdf). The documentation
provides a thorough overview of the natural gas module, describes the very detailed process-engineering
model and data sources used to characterize North American conventional, unconventional, and frontier
natural gas resources and reserves and to derive all the cost components incurred in bringing natural gas
from the ground to the pipeline. Also documented are the resource constraints, liquefied natural gas
(LNG), demand side issues, the natural gas pipeline network and capacity, procedures used to capture
pipeline transportation costs, natural gas storage, oil and natural gas liquids (NGL) assumptions, and key
gas market parameters. IPM modeling of natural gas prices uses both short- and long-term price signals
to balance supply of and demand in competitive markets for the fuel across the modeled time horizon.
As such, it should be understood that the pattern of IPM natural gas price projections over time is not a
forecast of natural gas prices incurred by end-use consumers at any particular point in time. The natural
gas market in the U.S. has historically experienced significant price volatility from year to year, between
seasons within a year, and even sees major price swings during short-lived weather events (such as cold
snaps leading to short-run spikes in heating demand). These short-term price signals are fundamental for
allowing the market to successfully align immediate supply and demand needs; however, end-use
consumers are typically shielded from experiencing these rapid fluctuations in natural gas prices by
retail rate regulation and by hedging through longer-term fuel supply contracts. IPM assumes these
longer-term price arrangements take place "outside of the model" and on top of the "real-time" shorter-
term price variation necessary to align supply and demand. Therefore, the model's natural gas price
projections should not be mistaken for traditionally experienced consumer price impacts related to
natural gas, but a reflection of expected average price changes over the time period 2015 to 2030.

Comment 139: Commenter 17868 asks that the EPA consider the infrastructure (pipeline and storage)
issues and other concerns found in the APPA study "Implications of Greater Reliance on Natural Gas for
Electricity Generation" found in Appendix M. [EPA-HQ-OAR-2009-0234-17868-A2]

Response to Comment 139: The EPA is familiar with the study and has considered it. The EPA's IPM
modeling includes natural gas pipeline requirements for coal-to-gas (CTG) conversions as described in
Documentation Supplement for EPA Base Case v4.10 PTox - Updates for Proposed Toxics Rule (
http://www.epa.gov/airmarkets/progsregs/epa-ipm/docs/suppdoc.pdf, Section 5.3.2).

Comment 140: Commenter 17627 quotes the Babcock & Wilcox White Paper MS-14 "Natural Gas
Conversions of Existing Coal-Fired Boilers" 2010 and recommends the EPA project capital costs based
on the B&W costs.

Response to Comment 140: The EPA is familiar with the study and has considered it. The EPA's IPM
modeling includes a coal-to-gas (CTG) conversion option as described in Documentation Supplement
for EPA Base Case v4.10 PTox - Updates for Proposed Toxics Rule (
http://www.epa.gov/airmarkets/progsregs/epa-ipm/docs/suppdoc.pdf, Section 5.3.1). In that
documentation, Table 5-11 Cost and Performance Assumptions for Coal-to-Gas Retrofits, provides
details of the assumed cost of boiler modifications for the CTG option. EPA's assumed $250/kW boiler
modification cost for a 75 MW unit is conservatively derived from the $50 to $75/kW costs estimated by
B&W for somewhat larger units using their "Option 1," as described in the cited B&W paper
(http://www.babcock.com/library/pdf/MS-14.pdf). Thus EPA's CTG option and B&W's CTG Option 1,

593


-------
both involve only modifications to the existing boiler; they do not involve higher cost approaches such
as the addition of a gas turbine (as in B&W Option 2).

Comment 141: Commenter 17879 explains that much of the manufacturing industry cannot pass along
increased input costs because it decreases competitiveness. The paper industry in particular is in decline,
the commenter reports, and increased natural gas and electricity costs could exacerbate the nation's
weak economic situation. The commenter worries that the widespread conversion from coal or oil to
natural gas by power plants will lead to an increase in natural gas consumption and costs.

Response to Comment 141: The EPA has designed a rule with as much flexibility as possible and in
accordance with the requirements outlined in the CAA for HAP. As discussed elsewhere in this
document, the EPA's analysis shows only modest conversion to natural gas and that coal will continue
to play a major role in the nation's energy economy. Additionally, the EPA believes energy efficiency
measures can be a complement to this rule, and can be an important tool in helping address emissions.
The EPA has not included all the likely additional energy efficiency measures that are likely to occur by
2015, but will continue to pursue energy efficiency improvements throughout the economy, along with
other Federal agencies, states and other groups. This will contribute to additional environmental and
public health improvements while lowering the costs of realizing those improvements.

Comment 142: Commenter 17711 discusses the unique concerns of paper mills that produce some of
their own electricity, but also purchase some. The commenter is concerned that the proposed rule will
increase costs and lead to some plants switching to natural gas, thus increasing the cost of natural gas,
putting jobs at risk.

Response to Comment 142: The EPA has designed a rule with as much flexibility as possible and in
accordance with the requirements outlined in the CAA for HAP. As discussed elsewhere in this
document, the EPA's analysis shows only modest conversion to natural gas and that coal will continue
to play a major role in the nation's energy economy. Additionally, the EPA believes energy efficiency
measures can be a complement to this rule, and can be an important tool in helping address emissions.
The EPA has not included all the likely additional energy efficiency measures that are likely to occur by
2015, but will continue to pursue energy efficiency improvements throughout the economy, along with
other Federal agencies, states and other groups. This will contribute to additional environmental and
public health improvements while lowering the costs of realizing those improvements.

Comment 143: Commenter 17853 discusses the cost effectiveness for coal-to-gas with respect to
increasing capacity for existing zero HAP base load EGUs, including natural gas. The commenter
provides Figure 1, which shows raw commodity prices, which shows natural gas to trend higher than
coal, but since natural gas is 1.67 times more energy efficient, natural gas is comparable to coal in
commodity prices. (See Insert EPA-HQ-OAR-2009-0234- 17853-A2_Figureland2Page3.doc.)

Response to Comment 143: . The EPA has provided an assessment of the economic impacts of the rule
on the power sector, which can be found in the RIA of the rule. The EPA generally agrees with
commenter's assessment, noting that it has designed a rule with as much flexibility as possible and in
accordance with the requirements outlined in the CAA for HAP. Source owners will be able to ascertain
the viability of coal to case conversion relative to other options for reducing HAP emissions.

Comment 144: Commenters 18480 and 18481 express concern that the cities of Beatrice and South
Sioux City, Nebraska will be unable to meet the compliance deadline. Both receive their electricity from
the Nebraska Public Power District, and the mix is 50% coal, 40% nuclear and the remainder wind,

594


-------
natural gas and hydro power. The coal plants use low-sulfur coal and have baghouses that have reduced
Hg emissions by 50%. An estimate of compliance costs show a preliminary cost of $1 billion, which
will lead to a rate increase. The commenters request that the EPA reconsider the proposed rule's
aggressive emissions limits and deadlines, in light of the economic effects.

Response to Comment 144: To the extent that sources have already installed significant emission
controls, the EPA anticipates that the additional costs of complying with this rule will be much less. As
discussed elsewhere in this document, electricity prices are not expected to increase significantly as a
result of this rule. Nonetheless, the EPA will work with relevant authorities to ensure a smooth transition
with this rule and address specific issues. Public utility commissions and other regulatory authorities
have extensive experience with regulatory requirements and treatment of costs to consumers, and are
prepared for responding to the cost of future pollution control equipment or other response measures. In
addition, there are certain provisions for granting utilities some additional time to comply, if conditions
warrant (see preamble).

Comment 145: Commenter 18486 expresses concern that the combined effect of the new rule will
increase the use of natural gas for electric generation and increase natural gas prices, decreasing
availability for other uses. The commenter reports that natural gas is used in the production of ammonia
for fertilizer and for heating and other purposed in the agricultural industry. The commenter states that
other agricultural sectors, such as dairy, are electricity intensive so they will be impacted by the cost
increases for electricity and natural gas. The commenter asks the EPA to consider reports by Brattle
Group, ICF, Credit Suisse, CRA, FBR, Wood McKenzie and Bernstein Research on the ways the
proposed rule will lessen the use of coal and increase natural gas use.

Response to Comment 145: The EPA's analysis of the impacts to the power sector can be found in the
RIA of the rule. The analysis indicates that only a small number of coal plants will retire, and coal-fired
generation will continue to be the largest source of electricity. The agency has analyzed resource
adequacy issues and finds that there is ample existing spare capacity to serve load after retirements are
factored in, and industry has also shown that it can build new capacity quickly in response to demand.
The EPA will work with relevant authorities to ensure a smooth transition with this rule. In addition,
there are certain provisions for granting utilities some additional time to comply, if conditions warrant
(see preamble). Natural gas supplies and reserves have increased significantly in recent years, and prices
have remained fairly stable since their peak in the early 2000s. The EPA anticipates this trend will
continue although there may be some modest price effects on natural gas markets due to this rule.

7. Compliance timeline and general timeline.

Comment 146: Commenter 17806 considers the compliance time limits imposed by the proposed rule
to be impossible to achieve in light of the other final or pending rules. The commenter believes the short
timeline for these rules will increase the cost of power in most regions and threaten reliability.

Response to Comment 146: See preamble and TSD on feasibility for further discussion. In addition,
there are certain provisions for granting utilities some additional time to comply, if conditions warrant
(see preamble).

Comment 147: Commenter 19199 believes the utilities will need more time to comply with the
proposed rule in order to acquire the materials and labor needed to construct and install the equipment
without creating unnecessary cost increases and an unreliable electricity supply. The commenter
believes the EPA should extend the time to allow flexibility in implementation of the proposed rule.

595


-------
Response to Comment 147: See preamble and TSD on feasibility for further discussion. In addition,
there are certain provisions for granting utilities some additional time to comply, if conditions warrant
(see preamble).

Comment 148: Commenter 19213 says that the proposed rule does not allow adequate time to comply.
The commenter states that the timeline brings a risk of needing to increase electricity rates significantly
and negatively impact the economy and federal budget.

Response to Comment 148: See preamble and TSD on feasibility for further discussion. In addition,
there are certain provisions for granting utilities some additional time to comply, if conditions warrant
(see preamble).

Comment 149: Commenter 19213 states that small utilities will have a difficult time getting vendors
and contractors to commit to projects, since large utilities will be seeking larger quantities of equipment.

Response to Comment 149: See preamble and TSD on feasibility for further discussion. In addition,
there are certain provisions for granting utilities some additional time to comply, if conditions warrant
(see preamble).

Comment 150: Commenter 17834 states that the proposed rule will require costs be passed on to
consumers, meaning state public utility commissions will be flooded with requests for rate increases
from utilities trying to recover expenditures. The short deadline will also result in a large number of
extension requests made to state permitting authorities, further burdening them.

Response to Comment 150: The implementation of this rule will be 3 years after its promulgation, or
the end of 2014. Public utility commissions have extensive experience with regulatory requirements and
treatment of costs to consumers, and are prepared for responding to the cost of future pollution control
equipment or other response measures. In addition, there are certain provisions for granting utilities
some additional time to comply, if conditions warrant (see preamble). Thus, there will be some time
before the impacts of this rule such as any increase in retail electricity prices become a concern. It also
should be noted that increases in retail electricity prices will be 3.1% on average in 2015, with a range
regionally from 1.3 to 6.3%. See preamble and TSD on feasibility for further discussion. In addition,
there are certain provisions for granting utilities some additional time to comply, if conditions warrant
(see preamble).

Comment 151: Commenters 17743 and 17761 express concern that the short compliance deadline will
require many facilities to be taken offline at that same time to make upgrades, leading to reliability
issues.

Response to Comment 151: See preamble and TSD on feasibility for further discussion. In addition,
there are certain provisions for granting utilities some additional time to comply, if conditions warrant
(see preamble).

Comment 152: Commenter 18538 states that the compliance timeline in the proposed rule does not
include time to plan and permit new facilities. The commenter believes the EPA assumes owners will be
able to determine which plants will retire on the first day of the proposed rule's implementation period.
However, the commenter explains that permitting, planning and construction can run longer than 3 years
and delays in construction are common. Transmission upgrades can also take longer than 3 years. Since
many of the new plants in Texas will be in the same areas, permitting could also take longer.

596


-------
Response to Comment 152: See preamble and TSD on feasibility for further discussion. In addition,
there are certain provisions for granting utilities some additional time to comply, if conditions warrant
(see preamble).

Comment 153: Commenters 17881 and 18033 expresses concern that even with a blanket 1-year
extension, the proposed rule still poses risk to the reliability of the nation's electricity grid and to
national security. The commenter asks the EPA to work with industry to lay the groundwork for the
Presidential exemptions, as allowed by the CAA.

Response to Comment 153: See preamble and TSD on feasibility for further discussion. In addition,
there are certain provisions for granting utilities some additional time to comply, if conditions warrant
(see preamble).

Comment 154: Commenter 15002 states that the proposed rule should regulate emissions to the average
emissions achieved by the top performing 12% of sources since this provides a satisfactory balance
between emission controls, the monetized value of the associated health benefits and the projected
costs. The commenter also urges the EPA to adopt a review schedule for Hg and HAP emissions, such
as a 5-year review cycle as defined under the CAA NAAQS review process.

Response to Comment 154: The rule will impose HAP emissions limits consistent with the
requirements of section 112(d) of the CAA. Although the EPA has conducted a detailed analysis of the
costs and benefits of the rule, the setting of a MACT floor is not based on the costs and benefits of
control. Setting standards beyond the MACT floor does consider costs and non-air quality health and
environmental impacts and energy requirements. The review cycle for standards such as this one is not
longer than 8 years as set forth in CAA section 112(d)(6).

Comment 155: Commenter 17654 reports that they will need to install add-on pollution controls to
meet the proposed emission standards as well as implement other physical or operational changes. The
commenter expresses concern about the number of pre-construction steps that would be required, as well
as the new construction activities and the challenges of scheduling sequence relative to interconnections
and other tie-in considerations involved in compliance.

Response to Comment 155: See preamble and TSD on feasibility for further discussion. In addition,
there are certain provisions for granting utilities some additional time to comply, if conditions warrant
(see preamble).

Comment 156: Several commenters (17681, 17886, 18441) have concerns about the tight timeframe
imposed by the proposed rule. Commenters 17681 and 17886 argue against the EPA's suggestion that
utilities should commit to capital projects before a final rule is completed. The commenters point out
that it is unwise to invest in emission strategies that may not be adequate to comply with the final rule.
The commenters state that many companies have had to stop their investments for strategies based on
prior rules because they are likely to be insufficient for the proposed rule. Rate-regulated states may not
be able to recover capital commitments made before the rule is final. Commenters 17886 and 18441
states that early decisions are not appropriate for a MACT rule as they may be for Clean Air Interstate
Rules, since the CAIR is a cap and trade program that allows flexibility, and the proposed rule requires
units to meet limits to be shut down. Commenters believe utility decisions on unit retirement versus
additional control installations must factor into all anticipated and existing regulations.

597


-------
Response to Comment 156: See preamble and TSD on feasibility for further discussion. In addition,
there are certain provisions for granting utilities some additional time to comply, if conditions warrant
(see preamble).

Comment 157: Commenter 19114 has determined that the proposed rule does not provide enough time
to permit, engineer, procure and construct the retrofits their fleet will need to meet the 2014 deadline.

Response to Comment 157: See preamble and TSD on feasibility for further discussion. In addition,
there are certain provisions for granting utilities some additional time to comply, if conditions warrant
(see preamble).

Comment 158: Commenter 17911 explains the different approaches used to obtain funding by a private,
stock or cooperative company as opposed to a municipality. A private company comes to an agreement
with an entity with funds to lend. Municipalities, on the other hand need approval from the voting public
to issue revenue bonds or general obligation bonds to begin the process of financing projects, often by a
super majority. Additionally, the commenter states municipalities are bound by publicly adopted budgets
that cannot be amended, so it may take up to 18 months to get approval to spend money for projects like
those necessitated by the proposed rule. The commenter also explains that municipal bonds have been
hit by threatened bankruptcies of municipalities, which makes it increasingly difficult to fund projects
and many municipalities have seen a reduction in their revenue streams, including sales tax and water,
wastewater or electricity utility bills. A downgrade in the U.S. credit rating may also change municipal
borrowing ratings, making money increasingly difficult to borrow. Municipalities are legally prohibited
from skipping or speeding up regulatory or legal processes. All of these factors make it difficult for
municipal utilities to move forward quickly with construction of new controls or generation.

Response to Comment 158: See preamble and TSD on feasibility for further discussion. In addition,
there are certain provisions for granting utilities some additional time to comply, if conditions warrant
(see preamble). In addition, the deductibility of federal tax on capital investment by municipalities may
make investment in pollution control somewhat less expensive relative to private, stock or cooperative
companies, who do not have this tax advantage for debt.

Comment 159: Commenter 18447 explains that they will not be able to plan, design, permit, bid and
build a new transmission line in 3 years. The commenter states that they have been working to build a
new transmission line without success since 2005. The commenter says that the initial cost estimate was
$18.2 million, but has now surpassed $29 million and will not be completed until 2012. The commenter
explains that when the city power plant is down, without this transmission line the power in the city will
go out any time the demand is greater than 63 MW. The commenter also says that committing resources
toward rule compliance before it is finalized is not an option as resources are only available when the
need is known.

Response to Comment 159: See preamble and TSD on feasibility for further discussion. In addition,
there are certain provisions for granting utilities some additional time to comply, if conditions warrant
(see preamble).

Comment 160: Commenters 17808 and 18421 do not believe that labor availability will constrain
control installation in the required timeframe and cites ICAC response that it will not for these reasons:

1.	Power sector has demonstrated ability to install large number of systems in short time period.

2.	Majority of coal plans have installed control systems already.

598


-------
3.	Fewer resource and labor-intensive control options being used for compliance.

4.	End users have utilized cost reducing and implementation efficiency strategies for efficient
deployment of technologies.

Response to Comment 160: The EPA thanks the commenter for their comments. These comments are
generally consistent with the conclusions of the agency's analyses on feasibility of control installations
for this rule as found in the TSD on this subject in the docket for this rulemaking.

Comment 161: Commenter 18498 considers the compliance schedule to create a regulatory
environment where reserve capacities will decrease and consumer costs will increase. The commenter
cites studies showing the proposed rules and others will cause 10 to 70 GW of coal retirement between
2015 and 2020. The commenter explains that replacement capacity cannot be operational prior to the
compliance timelines for retirement or retrofits of existing facilities. This results in an inefficient and
costly approach that could be addressed by extending the compliance deadlines to allow sufficient time
to plan for transition to other technologies in a manner that is cost effective and assures grid reliability.
The commenter requests the compliance deadlines to be increased to at least 5 years with extensions
allowed for 2 additional years.

Response to Comment 161: See preamble and TSD on feasibility for further discussion. The EPA has
analyzed resource adequacy issues and finds that there is ample existing spare capacity to serve load,
and industry has also shown that it can build new capacity quickly in response to demand. In addition,
there are certain provisions for granting utilities some additional time to comply, if conditions warrant
(see preamble). As discussed further in the preamble, compliance timeframes are prescribed by the
CAA.

Comment 162: Commenters 17812 and 18038 suggest that market realities of installing control
equipment will increase the cost of the equipment due to the timeframe for compliance. Commenter
18038 is especially concerned that the short timeline and resulting increases in costs will be a hardship
for those already having difficulty in the current economy.

Response to Comment 162: See preamble and TSD on feasibility for further discussion. In addition,
there are certain provisions for granting utilities some additional time to comply, if conditions warrant
(see preamble).

Comment 163: Commenter 18435 states that a wide range of technical and economically feasible
practices and technologies are available currently to meet the emission limits and are in use around the
country.

Response to Comment 163: The EPA agrees with the comment. Our report on feasibility of controls to
meet the requirements of this rule can be found in a TSD in the docket for this rulemaking.

Comment 164: Commenter 17403 disagrees with the employment impacts estimated by the EPA and
the estimated number of units expected to retire. The commenter states that a longer timeline would
allow the EPA to preserve employment opportunities while protecting the environment.

Response to Comment 164: The EPA has conducted an updated employment analysis which shows
some potential positive and negative employment changes from the rule, but overall expects the
employment impact to be relatively small in comparison to the affected sector and the overall economy.

599


-------
Comment 165: Several commenters (17409, 17736, 18441) express concern over the 36-month
compliance timeframe and urge the EPA to provide an extension of at least 1 year to avoid more plant
retirements and lost jobs than necessary. Commenters 17736 and 18441 go on to request a clear
explanation of the requirements to qualify for an extension and commenter 17736 requests automatic
qualification for replacement source provisions, regardless of location while commenter 18441 does not
request a blanket delay.

Response to Comment 165: See preamble and TSD on feasibility for further discussion. In addition,
there are certain provisions for granting utilities some additional time to comply, if conditions warrant
(see preamble).

Comment 166: Commenter 17627 discusses the length of time it takes to adhere to permitting
requirements and the time needed to design, engineer, fabricate and install equipment. The commenter
explains that all these resources will be limited as multiple facilities try to utilize them during the short
timeframe and several commenters (17881, 17911, 18933, 19212) agree with this assessment.
Commenter 19212 reports that the compressed timeline will inflate costs to twice that of a more
reasonable implementation period of 6 to 8 years, which is wasteful of rate payers money. The
commenter suggests petitioning Congress for additional time to ensure a reasonable outcome.

Response to Comment 166: See preamble and TSD on feasibility for further discussion. In addition,
there are certain provisions for granting utilities some additional time to comply, if conditions warrant
(see preamble). As discussed further in the preamble, compliance timeframes are prescribed by the
CAA.

Comment 167: Commenter 18025 explains that between 2008 and 2010, approximately 60 GW of coal
capacity was retrofitted with scrubber controls and the industry completed between 50 and 60 scrubber
retrofits in each of the years 2009 and 2010, which shows the industry can complete large numbers of
retrofits in a short time period. Commenter 18025 encourages the EPA to finalize the rule on the planned
schedule to avoid market uncertainty.

Response to Comment 167: We agree with the commenter and are issuing the rule consistent the
consent decree.

Comment 168: Commenter 18477 estimates that compliance with the proposed rule will require new
controls on 10 of Hawaiian Electric's 14 steam boilers, and the controls cannot be completed until 2018
without jeopardizing system reliability. This would increase costs for consumers by 5% in 2014, and
trend up to 10% for 2018 and later years. The commenter notes that the remaining boilers would be
retired, and the cost of replacement generation was not included in the estimates.

Response to Comment 168: See preamble for discussion of requirements for non-continental liquid oil-
fired EGUs.

Comment 169: Commenter 18538 believes the EPA has underestimated the time needed to plan, permit
and construct sufficient new generation and transmission to compensate for the retirements caused by
the proposed rule.

Response to Comment 169: The claims of retirements in recent studies of the impact of EPA rules are
addressed in the preamble for the final rule.

600


-------
Comment 170: Commenter 19121 states that the rule's timeline combined with over-regulated HAP
place a threat to grid reliability.

Response to Comment 170: The claims of retirements in recent studies of the impact of EPA rules are
addressed in the preamble for the final rule. As discussed in this document, the preamble, and other
supporting materials, the EPA disagrees that HAP are "over-regulated" by the rule.

8. Large burden, little environmental gain.

Comment 171: Several commenters (17681, 17731, 17761) state that the EPA has no data relating to
benefits from reducing non-Hg HAP, so the costs of the proposed rule exceed the HAP benefits by
29,000 times. Commenter 17761 states that the impact analysis was largely focused on Hg with little
support for other HAP reductions and failed to provide account of true costs and benefits.

Response to Comment 171: The benefits of this rule include the reductions in non-HAP emissions such
as SO2 and PM2.5 that will take place based on the EPA's modeling. These reductions are credible and
are considerable in size. The estimates of these benefits reflect extensive analysis that has been reviewed
by the EPA's SAB, and reflects the latest scientific understanding on the subject. These benefits
outweigh the total annual costs of the rule by at least six-fold. More information on the estimates and the
methodology for their preparation can be found in the RIA for the rule. In addition, we are not able to
monetize the benefits from reductions of non-Hg HAP that will take place, but it is clear that benefits
will occur from reductions of these HAP.

Comment 172: Several commenters (17765, 17840, 17931, 18018) state that the rule is one of the most
expensive in the history of the CAA and is a huge regulatory burden for little environmental gain.
Commenter 17840 states that a precise cost estimate for the proposed rule is not possible because of the
number of interrelated rules to be considered. The commenter states that little to no incremental public
health benefits will be realized in response to the proposed rule.

Comment 173: Commenter 17842 cites the EPA estimate that the rule will cost $10.9 billion and create
social benefits of $42 to $140 billion annually and states that other analyses suggest costs will be more
severe due to the cumulative impact of interrelated emission regulations.

Response to Comments 172 - 173: The EPA's analysis of the impacts to the power sector can be found
in the RIA of the rule. Industry has also shown that it can build new capacity quickly in response to
demand. The EPA has not provided a cumulative impact analysis of various rulemakings for a variety of
reasons, which are outlined in the preamble and elsewhere in this document.

Comment 174: Some commenters (17623, 17656, 17799, 17917, 17919, 18023) consider the proposed
rule to be the most expensive clean air rule ever. They point out the estimated $10.9 billion annual cost
in 2015 and approximate 1,200 existing coal-fired EGUs affected, both of which were estimated by the
EPA. Several commenters (17656, 17681, 17917) believe the EPA's estimates are incorrect and the true
cost will be far more due to cumulative effects of all proposed power sector rules, and indirect costs
from job losses, reduced productivity and competitiveness resulting from electricity costs. Commenters
ask the EPA to keep these high costs in mind when evaluating impacts of the proposed rule and consider
the costs with respect to the benefits. Commenter 17681 in particular requests that the EPA explain how
its approach utilized "the best available techniques to quantify anticipated present and future benefits
and costs as accurately as possible." and include analyses by EIA, EEI, NERC, NERA, Credit Suisse,
ICF and Burns & McDonnell.

601


-------
Response to Comment 174: The EPA's analysis of the impacts to the power sector can be found in the
RIA of the rule. The methodology applied in that analysis was subjected to extensive external peer
review and this is documented in the RIA and supporting materials. In contrast, not all of the analyses
cited by the commenters are completely transparent, and the lack of sufficient documentation of
methodologies and assumptions prevents the EPA from subjecting them to critical review. Industry has
also shown that it can build new capacity quickly in response to demand. The EPA has not provided a
cumulative impact analysis of various rulemakings for a variety of reasons, which are outlined in the
preamble and elsewhere in this document. The EPA has conducted an updated employment analysis
which shows some potential positive and negative employment changes from the rule, but overall
expects the employment impact to be relatively small in comparison to the affected sector and the
overall economy.

Comment 175: Commenter 17637 states that the emission reductions achieved by the proposed rule
would be realized by other rules such as the NAAQS for PM, SO2 and SO3 and related transport
rules. As such, the benefit of adding further control equipment and work practices will be minor.

Response to Comment 175: The emission reductions from these rules are based on the agency's best
estimates of how emissions of HAP and non-HAP pollutants are affected by the control options
examined for this proposed rule. The RIA accounts for the impacts of other previously adopted rules.
These reductions in emissions lead to substantial benefits associated with the rule as shown in the RIA
for the rule.

Comment 176: Commenter 17386 reports that their municipal plant will incur significant costs while
removing minimal HAPS from their two small (28 MW and 114 MW) units, which have limited
operating time and combust only fuel oil and natural gas.

Response to Comment 176: Natural gas-firing is not impacted by this rule, and the EPA has included
analysis for some modest improvements available to oil-fired units to achieve compliance, which can be
found in the RIA.

Comment 177: Multiple commenters (17403, 17640, 17751, 17774, 17775, 17921, 18026, 18033,
18488, 19114, 19211, 18023) quote the NERA study that looked at combined economic impacts of the
proposed rule and the Transport rule and projected an $18 billion per year cost. The study also estimates
an increase in electricity prices of 11.5 to 23% and an increase in natural gas prices as a result of the
proposed rules as well. Commenters go on to say that manufacturers will not all be able to absorb the
higher costs and quotes the NERA study's prediction of 1.44 million job-years lost by 2020 if the
proposed regulations are implemented. Commenters 17774 and 17775 agree with this and quote the
estimate of 48 GW of coal-fired electric generating capacity (15% of the U.S. fleet) projected to retire in
response to the proposed rule. Commenter 17921 states that not all potential health benefits of the
proposed rule are monetized in the EPA impact analysis, so the total benefit of $50 billion per year is
likely to be a low estimate. However, the benefit still exceeds the costs predicted by the EPA or NERA,
and the commenter believes the rule will benefit children's health and carry a financial benefit as
well. Commenter 18026 states that Ohio can't afford the job losses or price increases. Commenter 19114
points out that new natural gas units require 75% fewer people per megawatt of capacity than coal.
Commenter 19211 states that some manufacturers will be unable to absorb the price increase and will
have to close or decrease production.

Response to Comment 177: The agency's analysis finds that the nationwide average increase in retail
electricity price is 3.1% in 2015, and no region of the country will experience an increase in price of

602


-------
greater than 6.3%. Natural gas prices will increase as an outcome of the rule, but the increase will be no
more than 1% on average from 2015 to 2030. We estimate 4.7 GW of coal-fired EGU capacity will
retire early by 2015 and that short-term construction labor will experience an increase of 46,000 job-
years as an outcome of the rule. Also, in the long-term, there is an impact on labor on an annual basis
ranging from a loss of 15,000 jobs to an increase of 30,000 jobs associated with the rule. Finally, the
benefits of the rule are estimated to exceed the $9.6 billion annual cost of the rule in 2015 even though
there are several benefit categories that could not be monetized, including the health and other effects
associated with non-Hg HAP. All of these analytical results can be found in the RIA for the rule, and
various TSDs for the rule also further document various results and the methodology for their
estimation.

Comment 178: Commenter 17702 believes that by expanding the proposed rule beyond what is
necessary to meet the remand and vacatur, the EPA created additional costs without improving air
quality.

Response to Comment 178: The agency has issued its rule consistent with the DC Circuit Court's
vacature and with the requirements of CAA section 112(d).

Comment 179: Some commenters (17800, 17806, 17884, 18014, 18018) consider the estimated costs of
complying with the proposed rule ($10.9 billion in 2015) to outweigh the estimated benefits of
controlling toxic emissions ($4 to $6 million) and therefore neither "appropriate" nor "necessary" as
required.

Response to Comment 179: The benefits of this rule include the reductions in non-HAP emissions such
as SO2 and PM2.5 that will take place based on the EPA's modeling. These reductions are credible and
are considerable in size. The estimates of these benefits reflect extensive analysis that has been reviewed
by the EPA's SAB and reflect the latest scientific understanding on the subject. These benefits outweigh
the total annual costs of the rule by at least six-fold. More information on the estimates and the
methodology for their preparation can be found in the RIA for the rule. In addition, we are not able to
monetize the benefits from reductions of non-Hg HAP that will take place, but it is clear that benefits
will occur from reductions of HAP emissions from EGUs. Conclusions regarding the appropriate and
necessary finding under section 112(n)(l)(A) of the CAA can be reviewed in the elsewhere in the final
rule record.

Comment 180: Several commenters (17765, 17840, 18033) find the proposed rule to produce little to
no public health or environmental benefit while imposing unnecessary costs or losses of employment.
Commenters state that the pollutants are already regulated under the NAAQS program or other
regulations.

Response to Comment 180: The agency has estimated the benefits of this rule to be 5 to 13 times the
size of the costs in its RIA. Thus, this rule will be beneficial given this comparison of benefits to costs.
The reductions of pollutants regulated under the NAAQS are co-benefits from the HAP emissions limit
requirements in the rule, and occur concomitantly with the HAP reductions.

Comment 181: Commenter 18421 cites the EPA's estimate that the proposed rule will yield monetized
net benefits of up to $130 billion every year, once the rule is in place. These benefits outweigh the costs
by 5 to 13 times. The commenter explains that the estimates are conservative since not all benefits could
be monetized, such as health and ecosystem benefits of reducing nitrogen and sulfur emissions and
deposition and vegetation benefits from reducing ozone.

603


-------
Response to Comment 181: The agency agrees with the commenter.

Comment 182: Commenter 18428 considers the proposed rule to be very costly while offering few
benefits. The commenter points out that since the year 2000, their company has achieved a 62%
reduction in Hg.

Response to Comment 182: The agency has estimated the benefits of this rule to be 5 to 13 times the
size of the costs in its RIA. Thus, this rule will be beneficial given this comparison of benefits to costs.
The benefits and costs from additional mercury reductions are included in these estimates. To the extent
that companies have already installed significant emission controls, the costs of complying with this rule
will be less.

Comment 183: Commenter 19041 considers the health benefits to be overstated and the costs
underestimated. The commenter and commenter 19114 cite the AEP estimate of $6-8 billion in capital
costs needed in addition to the $7.2 billion already spent since 1990, and a retirement of 6,000 MW of
capacity to comply with the proposed rule. The commenters say that if one utility will need to do so
much to comply, the EPA estimate must be low

Response to Comment 183: The agency has provided the most accurate estimates of benefits and costs
possible using peer-reviewed models and comprehensive data. The RIA for this rule explains the basis
for the benefits and costs and the uncertainties in the results. The agency also estimates that about 2% of
coal-fired EGU capacity nationwide may retire early as a result of the rule, and this estimate is based on
calculations from IPM, a peer-reviewed model.

Comment 184: Commenter 18477 asks that the EPA consider the natural air quality that exists in
Hawaii and other island locations. The commenter explains that trade winds give Hawaii and other
islands some of the best air quality in the nation such that they meet all the NAAQS, so the proposed
rule would have minimal impact on air quality despite high costs. The commenter urges the EPA to
develop a separate RIA for non-continental oil-fired units.

Response to Comment 184: This rule is a NESHAP, not a rule to implement a NAAQS, and is imposed
nationwide consistent with section 112 of the CAA. However, the EPA has adopted provisions for non-
continental liquid oil-fired units in the final rule and has provided an analysis for non-continental oil-
fired units as part of the RIA for the final rule.

9. State regulators.

Comment 185: Commenters 16859 and 17174 request that the EPA consider the burden of the proposed
rule and other recently promulgated rules on the resources of individual states. Commenters ask that the
EPA develop a rule that reduces air pollution and provides efficient implementation and enforcement
strategies for the delegated authorities. Commenter 16859 asks that the EPA consider ways to secure
federal funding for states to cover costs associated with state implementation of the proposed rule and
details the many obligations and costs for state agencies. The commenter explains that costs of
implementation of the rule can be covered two ways. The first is through U. S. Congressional
appropriations. The other is through increases in permit fees allowed for Title V activities in the CAA.
The commenter says it may not be expedient to receive state legislative approval for permit fee increases
and states that if the EPA estimates state administrative costs, along with state direct compliance costs,
the estimates might assist both the EPA in justifying their request for appropriations and states in
justifying permit fee increases. The commenter requests the EPA consider state administrative costs and

604


-------
make this information available as directed in UMRA, EO 12866 and EO 13132. The commenter urges
the EPA to accurately assess the implementation costs on states, so the rule may be implemented
properly and in a timely manner to avoid adverse health effects.

Commenters 16859 and 17400 explain that for each new EPA rule, states may incur slightly different
implementation costs. These commenters note that cost categories vary from state to state depending on
legislative and regulated community differences. One commenter asks that the EPA consider state costs
for a wide-range of implementation start-up and recurring activities in the implementation cost
estimation for this rule, while others discussed in the attachment included with the original comment.
The attachment details several implementation costs that must be accurately assessed for the rule to be
implemented properly and in a timely manner without adversely affecting human health. The commenter
also asks that the EPA seek federal funding for the states to cover the customary portion of the costs
associated with state implementation and consider the availability of funding support in its planning for
new rule adoption schedules and other implementation activities following the rule issuance.

Response to Comment 185: The agency has addressed the impacts on state and municipal agencies in
compliance with UMRA and EO 12866 and 13132. Additionally, the EPA estimated the costs of
implementation of the rule to states and has included this analysis in the RIA. The agency has updated
this analysis for the final rule and included it in the RIA. The reductions in air pollution from the rule
should be substantial and are well elaborated on in the RIA and in technical support documents found in
the docket for this rulemaking. The agency will respond accordingly to requests for additional state and
local agency funding if it is determined that such funding is needed for implementation of this rule.

Comment 186: Commenter 17629 explains that a settlement agreement on a rate case in Wyoming
created a new layer of review by Public Service Commission to examine the Public Need and Necessity
for passing on environmental control costs to consumers. The commenter anticipates that the analytical
burden associated with this rule and others recently proposed will increase and reliance on the EPA's
technical and economic analyses will not be sufficient. The commenter urges the EPA to take steps to
change the Grant Agreements to reflect the additional burdens to states.

Response to Comment 186: The agency may consider changing Grant Agreements and help states in
other ways if the analytical burden to them is substantial enough to warrant agency action.

Comment 187: Commenter 17620 discusses the increased workload of state and local air pollution
control agencies as a result of the proposed rule. The commenter explains that the EPA has proposed a
number of alternate compliance options that will reduce compliance costs for industry, but increase the
cost of administering the program. The commenter states that in delegated states, permitting authorities
will also conduct inspections and commence enforcement actions where sources are found to be in
noncompliance, which is important because of the large amount of toxic air emissions that are involved,
but cannot be undertaken without resources. The commenter points out that increased funding is
unlikely to be available and urges federal grant funding be provided under sections 103 and 105 of the
CAA during those years when the majority of implementation activities will occur.

Response to Comment 187: The agency will respond accordingly to requests for additional state and
local agency funding if it is determined that such funding is needed for implementation of this rule.

Comment 188: Commenter 17620 states that the reductions in SO2 and PM2.5 required by the proposed
rule will assist state and local air pollution control agencies to meet health-based air quality standards,
reduce haze and improve visibility. The commenter points out that substantial reduction in emissions

605


-------
made by the very large sources under the proposed rule will lead to fewer pollution controls needed at
smaller sources to meet health-based ambient air requirements. This is a far more cost-effective
approach than controls at smaller facilities and is the lowest cost path to improved public health and a
cleaner environment.

Response to Comment 188: The EPA thanks the commenter for the comments. The MATS is a
standard to reduce HAP, but we are also finalizing revisions to the NSPS for NOx, SO2, and PM
emissions limits for utilities. Much of the HAP requirements will also lead to co-benefits such as PM2.5
and SO2 reductions that could be of aid to states working on implementation of various NAAQS and
regional haze strategies.

Comment 189: Commenters 17743 and 17745 express particular concern over the proposed rule's
impacts on the burden on the permitting authorities in light of the other current and pending EPA air
rules also adding to the expected workload. Commenters 17174 and 17834 ask the EPA to consider the
burden of the proposed rule that is placed on state agencies and develop a rule that reduces air pollution
but provides for efficient implementation and enforcement.

Response to Comment 189: The agency is careful to mitigate the impacts of this rule to permitting
authorities to the extent possible. The agency will respond accordingly to requests for additional state
and local agency funding if it is determined that such funding is needed for implementation of this rule.

10. Miscellaneous.

Comment 190: Commenter 18447 asks that the EPA consider the best interest of the U.S. in creating
policies. The commenter asks if other countries are willing to hurt their economies to be a good global
neighbor and states that history shows they will not.

Response to Comment 190: The agency has prepared this rule in response to the requirements of the
CAA and a court mandated consent decree. The vast majority of benefits resulting from this rule will be
experienced in the U.S., not outside of it. Additionally, through a variety of working groups and treaty
organizations, the EPA participates in international negotiations to address transboundary air pollution
and to achieve a level playing field in the control of air pollution.

Comment 191: Commenter 17409 quotes a Stanford University study that says the U.S. could be run
entirely on clean energy within 10 years, at reasonable cost. The commenter goes on to acknowledge
other innovations in the power generation industry and points out that new regulations inspire new
knowledge and industries find new ways to do things better, and more cheaply, making the U.S. more
competitive in the global market.

Response to Comment 191: We agree with the commenter that new regulations such as this rule could
serve to spur innovation to make energy production cleaner, a trend already distinct in the electric power
sector and that innovation has historically occurred at a more rapid pace than predicted.

Comment 192: Commenter 17855 discusses the difficulties for waste coal industry in complying with
the proposed rule. The commenter explains that the waste coal industry is reclaiming abandoned mining
sites to avoid discharging acid mine drainage, at no cost to the taxpayers. The commenter explains that
waste coal power plants control NOx and SO2 and PM currently, but may be forced to install expensive
new controls, which may make the plants economically unviable and lead to an end of mine remediation
without public funding. The commenter explains that waste coal plants are small plants designed to use

606


-------
local waste coal and which do not have the ability to pass costs on to customers or switch to another fuel
to meet proposed limits.

Response to Comment 192: As noted elsewhere in this document, coal refuse-fired EGUs are among
the units making up the MACT floor pools for all of the HAP. Thus, we believe that such EGUs are
capable of achieving the limits in the final rule and are not economically unviable as suggested by
commenter. Should additional controls be required at certain facilities, such controls can be added just
as at other EGUs. Facilities that have already achieved significant control of emissions are likely to face
lower costs to comply with today's rule.

Comment 193: Commenter 17867 explains the Boardman 2020 Plan as an innovative approach to
achieving environmental goals by ending coal-fired generation at relatively young and efficient EGUs.
The commenter cites to key features contributing to successful discussions among diverse stakeholders
to produce an outcome that achieved a remarkable level of consensus for the future of the Boardman
Plant and for the people and natural environment of Oregon:

1.	A state-adopted agreement with broad and diverse stakeholder support;

2.	An enforceable agreement to cease coal operations by a date certain;

3.	A reasonable amount of time before the end of coal operations to address concerns regarding
community impacts, including jobs at the facility, replacement of the energy resource that considers
cost to customers, reliability and resource diversity, and consistency with CAA requirements;

4.	Interim emission controls that appropriately address human health and environmental impacts for the
remaining period of coal-fired operations; and

5.	A robust resource planning process that considers low carbon replacement resources among the
viable alternatives.

In the case of Boardman 2020, the commenter explains the combined strategy of early cessation of coal
operations and interim controls will result in lower aggregate emissions of haze causing air pollutants
than those projected under a much more expensive control package that would have otherwise been
required to run the plant indefinitely.

Numerous commenters (13902, 14279, 14481, 14695, 14696, 15161, 15590, 15636, 15680, 15823,
15824, 15883, 16406, 16681, 16683, 16825, 17021, 17153, 17194, 17298, 17307, 17308, 17847, 17867,
17872, 17874, 17894, 17899, 17900, 18052, and 18485) urge the EPA to recognize and accommodate
appropriate solutions like Oregon 's Boardman 2020 plan to allow the agreement to be fully achieved.
The commenters believe that the final NESHAP rule for EGUs needs to clearly recognize this
innovative Oregon approach and provide regulatory flexibility to accommodate the Boardman plan
within the framework of the CAA. The Boardman 2020 Plan is discussed in further detail by
commenters 17867 and 18019.

Response to Comment 193: We thank the commenters for their comments. The timing for
implementation of this rule is set in the CAA. We will allow flexibility in compliance, both in method
and timing, consistent with the CAA.

Comment 194: Commenter 18039 believes that power plants in Massachusetts and other states with
reduced Hg limits have been placed at a competitive disadvantage and do not get the full benefit of their
own reductions as a result of being downwind of states which do not impose similar rules. The
commenter sees the proposed rule as going a long way to address this current inequity.

607


-------
Response to Comment 194: We agree with the commenter that implementation of this national rule
may level the playing field, as it were, regarding Hg controls across the country.

Comment 195: Commenter 18961 believes the rules will level the playing field by imposing universal
standards for all coal-fired units, reducing uncertainties in the industry and easing long-term planning.
The commenter points out that the standards can be met through existing technology within the
compliance timeline. The commenter also believes that by retrofitting or retiring out-dated coal-fired
power plants, the industry will improve the reputational risks and relations with local communities and
regulators. The commenter shares results from a poll saying that 79% of Americans are in favor of the
EPA placing stricter limits on Hg from power plants.

Response to Comment 195: The EPA agrees with the commenter.

Comment 196: Commenter 19042 cites the Executive Orders and policy directives from the Obama
Administration that encourage federal agencies to increase sustainability, reduce emissions and conserve
energy. The Administration claims this will reduce electricity costs by $1.7 to $2.1 billion from 2010 to
2020. However, the commenter points out that the capital costs are not included in these estimates, and
even if no capital costs were needed, the reduction would still be less than the increase due to the
proposed rule. The commenter also points out that there has been significant interest in the proposed rule
in Congress, and it may be appropriate for review under the provisions of the Congressional Review
Act. The commenter states that the impacts analysis is flawed because:

1.	it fails to account for the unfunded mandate to every department and agency of the federal
government that either generates or purchases electricity;

2.	our analysis of the RIA found no discussion of federal budget costs;

3.	there are no estimates reported by the federal departments and agencies in their budget projections or
in the budget justification materials provided to Congress; and

4.	based on informal contacts with senior federal facility energy managers, we have found no evidence
that interagency review of the Utility MACT standards considered federal compliance costs and
budgetary priorities.

Response to Comment 196: Every major rule is subject to the CRA and this rule is no exception.
UMRA is inapplicable to instrumentalities of the federal government and by its terms applies to federal
actions that have impacts on state, local, tribal governments or private entities. The EPA's analysis
projects a near-term increase in the average retail electricity price of 3.1% in 2015 falling to 2% by 2020
under the final rule in the contiguous U.S.

Comment 197: Commenter 19042 discusses the federal deficit of $1.6 trillion and the states' deficit of
$130 billion and points out that the proposed rule will affect the federal budget in two ways:

1.	direct compliance costs to electric generating units (EGUs) owned by federal agencies; and

2.	pass-through compliance costs paid in the form of higher prices for electricity purchased by federal
agencies.

Response to Comment 197: The agency estimated the increase in direct compliance costs at federally-
owned EGUs, and that estimate for the proposed rule is available in the docket. This estimate has been
revised for the final rule. The agency estimated the retail electricity price nationwide to increase on
average by 3.7% in 2015 as a result of the rule. The agency does not expect this increase in price to lead
to significant increases in federal government agency operating costs.

608


-------
Comment 198: Commenter 19042 notes the EPA identified 96 state and local government entities with
a combined total of 169 EGUs that will have to comply with the Utility MACT standards. For these
potentially affected units, the EPA estimated the cost of compliance, setting that cost equal to the change
in operating and capital expenditures, plus the change in fuel costs, plus the change in revenues resulting
from the sale of electricity to consumers at presumably higher retail prices.

The results of the EPA UMRA analysis are depicted in Table 1 and Table 2 in the original letter. (See
EPA-HQ-0AR-2009-0234-19042-A2, 19042_Table_l.doc and 19042_Table_2.doc.)

In the RIA, the EPA notes that its "[UMRA] analysis does not examine potential indirect economic
impacts associated with the proposed [Utility MACT] rule, such as employment effects in industries
providing fuel and pollution control equipment, or the potential effects of electricity price increases on
industries and households.

Each agency's annually updated SSPP is intended to prioritize agency sustainability activities based on
lifecycle return on investment. OMB provides periodic evaluation of each agency j|s performance via a
Sustainability and Energy Scorecard (SES). All scorecards are published on CEQ's website.33 Agencies'
SSPPs show that OMB assigned a "green light" score to the proposed scope 1 and 2 GHG emissions
targets set by the federal agencies with the largest electricity consumption. The commenter goes on to
say that the Administration claims that achievement of the scope 1 and 2 GHG emissions targets will
reduce federal spending. In particular, with respect to purchased electricity, in recent testimony before
the U.S. Senate, CEQ Chair Nancy Sutley made the following statement:

"If annual greenhouse gas emissions decrease incrementally to produce a reduction equal to five % of
calculated base year emissions, the Federal government will save an estimated $1.7 to $2.1 billion in
avoided utility costs over the period 2010 to 2020." However, the commenter points out that the
Administration provided no justification for the proposed savings. More importantly, the Administration
has provided no estimates of the upfront capital investment that will be required in order to deploy new
clean energy and energy efficiency measures need to achieve the savings. The commenter points out that
the cost of electricity purchases is a significant cost in the federal budget. As a result of the proposed
Utility MACT standards, these costs will increase, obviating any potential savings claimed by the
Obama Administration due to implementation of EO 13514: Federal Leadership in Environmental,
Energy, and Economic Performance. The commenter states that their analysis shows that the SSPP
reports and scorecards failed to report the base year electricity and associated GHG emissions data, so it
is not possible to determine the percent reduction in GHG emissions associated with electricity
consumption. Thus, these assertions may have more of a political bent than an analytical basis. (See
http://www.whitehouse.gov/administration/eop/ceq/sustainabilitv/omb-scorecards.)

Response to Comment 198: The agency estimated the retail electricity price nationwide to increase on
average by 3.7% in 2015 as a result of the rule. The agency does not expect this increase in price to lead
to significant increases in federal government agency operating costs.

Comment 199: Commenter 19042 provides analyses of the estimated federal budget impacts, taking
into account the variation by region. However, since publically available data is aggregated by agency,
disaggregation by region was not possible, and the commenter suggests the government do this analysis.
Instead, the commenter based estimates on federal activity within each state. The commenter used the
EPA RIA price increase to estimate federal electricity costs incurred due to the proposed rule. The result
was an increase of $166 million per year. The commenter recommends further analysis to estimate the

609


-------
magnitude of the unfunded mandate being imposed on states and local governments and the cumulative
impact of pending EPA rulemakings.

Response to Comment 199: The agency has revised its UMRA analysis for the final rule. The agency
did not prepare a cumulative impact analysis to accompany the rule for the following reasons: 1) the
various EO requirements that the agency must comply with require us to estimate impacts specific to
this rule; 2) decision makers and the public need to know the impacts specific to a particular rule in
order to judge the merits of the regulation; 3) estimates specific to a particular rule are more transparent
than those from a cumulative impact analysis. A cumulative impact analysis lumps several regulations
together and can potentially mask a high-cost/low-benefit regulation among other rules that may have
large net benefits. By analyzing each regulation separately, the EPA makes clear statements about what
impacts, costs, and benefits will be generated as a result of this particular regulation.

This does not, however, mean EPA has failed to consider cumulative impacts of the regulation. The
inclusion of CSAPR and other regulatory actions (including federal, state, and local actions) in the IPM
base case reflects the level of controls that are likely to be in place in response to other requirements
apart from MATS. This base case provides meaningful projections of how the power sector will respond
to the cumulative regulatory requirements for air emissions, while isolating the incremental impacts of
MATS. These results are presented in Chapter 3 of the RIA.

Additionally, the Agency does reflect on the broader cumulative impacts of our regulations. In March
2011, EPA issued the Second Clean Air Act Prospective Report which assessed at the benefits and costs
of regulations pursuant to the 1990 Clean Air Act Amendments. The study examines the cumulative
impact of these regulations (found at http://www.epa.gov/air/sect812/febl 1/summaryreport.pdf). As
shown in the report, the direct benefits from the 1990 Clean Air Act Amendments reach almost $2
trillion for the year 2020, a figure that dwarfs the direct costs of implementation ($65 billion). The full
report is at http://www.epa.gov/air/sect812/prospective2.html.

The direct benefits of the 1990 Clean Air Act Amendments and associated programs significantly
exceed their direct costs, which means economic welfare and quality of life for Americans were
improved by passage of the 1990 Amendments. The wide margin by which benefits exceed costs
combined with extensive uncertainty analysis suggest it is very unlikely this result would be reversed
using any reasonable alternative assumptions or methods. This conclusion is likely to also be attributable
to this rule as shown in the RIA.

Comment 200: Commenter 17690 believes the proposed rule could have unintended impacts on
deregulated oil-fired units that rely on operating revenues and will be unable to have enough projected
revenues to justify the cost of compliance. These units may be prematurely retired.

Response to Comment 200: Our analysis of the impact of the rule on oil-fired units indicates that the
costs per unit should be modest, and thus the probability of premature retirement for such units is low.

Comment 201: Commenter 17648 considers the EPA to have coordinated the various programs
involving power plants to be effective and explains how the IPM modeling shows the benefits of
implementation of the rules. The commenter reports investing nearly $5 billion in clean energy
generation and Smart Grid technology and from this experience considers the EPA's modeling to be
unduly conservative. The commenter agrees with the EPA's modeling that shows the closure of older
plants and replacement by gas-fired plants of various types and believes that expansion of nuclear and
alternative energy sources will occur as well. The commenter also explains that the proposed rule and

610


-------
other new regulation will increase the efficiency of the fleet, further benefitting the economy. The
commenter questions the report, "Methane and the Greenhouse-Gas Footprint of Natural Gas from Shale
Formations" because it does not account for increased efficiency of gas-fired plants and used the wrong
conversion factors from methane to carbon dioxide equivalents.

Response to Comment 201: We agree with the commenter that this rule could lead to an increase in the
energy efficiency of the electric power boiler fleet.

611


-------
6J - Impacts/Costs: Social Costs

Commenters: 11107, 16207, 16824, 16850, 17254, 17408, 17409, 17620, 17709, 17713, 17727, 17766,
17775, 17811, 17842, 17875, 17884, 18432, 18435, 18436, 18541, 18961, 19536/19537/19538

Comment 1: Multiple commenters (16207, 17408, 17620, 17811, 18961, 19536, 19537, 19538)
describe the health benefits of the rule, including the $59 billion to $140 billion each year, or $5 to $13
in health benefits for each dollar spent on compliance as opposed to the estimated $10.9 billion annual
cost.

Response to Comment 1: The benefits of this rule as estimated by the agency are quite substantial
relative to the costs. These benefits include those associated with the estimated Hg reductions as well as
the reductions in other pollutants such as fine PM and S02. The agency has prepared an extensive
analysis of the benefits and costs of this rule which is found in the RIA.

Comment 2: Commenter 16824 considers the potential health benefits of the rule to be questionable
because it will have no effect on the levels of Hg and other emissions that occur naturally. The
commenter considers the rule to be adversely affecting efforts to stimulate the economy and job growth
and causing electric rates to rise.

Response to Comment 2: The agency's analyses of costs and benefits reflect the latest, peer-reviewed
science that is available. The benefits analysis is based on peer-reviewed scientific literature, the review
of EPA's SAB, and also on the inputs of experts in setting values for benefits for categories such as
premature mortality. The benefits estimates reflect the reductions in emissions estimated for this rule,
and are incremental to a baseline that includes the impacts of regulatory programs up to December 2010.
The agency's cost analyses are also based on peer-reviewed studies and analyses. The RIA for the rule
documents both analyses.

Comment 3: Commenter 16850 explains that Florida's investor-owned electric utilities can petition to
recover the costs associated with the proposed rule through a cost recovery clause subject to FPSC
review. The commenter provides monthly averages for the increase in residential customer costs for
every $100 million in environmental compliance costs recovered. These costs range from $1.27 to
$10.90 for a 1200 square foot residence. The commenter expresses concern for the Florida consumers,
approximately 85% of whom rely on electricity for heating and cooling, and include a large portion of
senior citizens on fixed incomes.

Response to Comment 3: The agency estimates that the nationwide retail electricity price increase
associated with the rule will be 3.1% in 2015, and there will be some variation in this price increase
among different regions. No region of the country, however, is estimated to experience an increase in
price of greater than 6.3%. In Florida, the increase in retail electricity price is estimated to be 2.2% in
2015 for the power region that includes the State of FL. State and local rate setting agencies are best
equipped to deal with the issues concerning higher electricity rates in their areas.

Comment 4: Commenters 16207 and 17620 discuss health benefits, such as the 6800 to 17000 people
saved from premature death, 120,000 prevented asthma attacks, 850,000 employee sick days avoided
and the thousands of short and long term jobs created by the rule.

Response to Comment 4: The EPA thanks the commenter for these comments. The benefits of this rule
are substantial, both on their own and relative to the costs. The reduction in incidences and how they are

612


-------
estimated can be found in the RIA for the rule. The employment impacts estimated by the agency for the
rule reflect both construction labor associated with new control equipment likely to be needed to meet
the rule requirements, and operation of these controls, and the reaction of the economy to this rule is also
taken into account. The RIA for this rule contains the analysis methodology and results for employment
changes.

Comment 5: Commenters 17709 and 17727 express concern about the cost of implementing the
proposed rule. The commenters cite an announcement by the American Electric Power company that
rates would increase in response to the proposed rule and ask that the proposed rule be reconsidered and
implemented with a compliance plan that will allow the utilities to continue operating their coal-fired
plants without additional stipulations that will increase rates. Commenter 17709 states that the rule will
exacerbate the slow recovery in the state of Michigan.

Response to Comment 5: The agency estimates that the nationwide retail electricity price increase
associated with the rule will be 3.1% in 2015, and there will be some variation in this price increase
among different regions. No region of the country, however, is estimated to experience an increase in
price of greater than 6.3%. The agency is cognizant of the estimated price increases. State and local rate
setting agencies are best equipped to deal with the issues concerning higher electricity rates in their
areas.

Comment 6: Commenters 17713 and 17766 state that African Americans and Hispanics are worse off
than Caucasians by economic measures and tend to be more vulnerable to economic downturns and job
losses resulting from EPA regulations. Commenter 17766 explains that 71% of African Americans and
80%) of Hispanics live in an area that fails to meet one or more EPA air quality standard, compared to
57%) Caucasians. Also, the commenter notes that 68%> of African Americans and 39% of Hispanics live
within 30 miles of a coal-fired power plant. The commenter states that this close proximity to power
plants means that they are more likely to be a risk to develop health issues than those who live in cleaner
neighborhoods. The commenter goes on to add that because these same people are more likely to live in
poverty, they are less able to move from heavily polluted areas.

Response to Comment 6: We understand the commenters' concerns. The reductions in Hg will lead to
improved health in populations in close proximity to coal-fired power plants, and the benefits from these
reductions are discussed at length in the RIA for the rule. We show the benefits of Hg and HAP
emission reductions, along with the substantial benefits from reductions in emissions of PM, SO2, and
other pollutants in our RIA. Populations that are the focus of EO 12898 (low-income, minority) will
benefit from these reductions as shown in the RIA.

Comment 7: Commenter 17775 explains that for EPA benefit estimates to be accurate, up to 20% of
annual deaths in large areas of the country were due to ambient PM2.5 exposures in 2005. The
commenter states that these high assumptions are the result of an assumption change made by the EPA
in 2009 to start calculating mortality risk in its risk assessments below the lowest measured levels,
which has not been subjected to peer review. The commenter believes this change inflates the baseline
of PM2.5-related deaths and points out the EPA estimate of deaths among those exposed to PM2.5 levels
of 12ug/m3 went from almost 3% to nearly 13% as a result of the changed assumption. The commenter
calculates that the percentage would be even higher if the higher pollution levels of the past two decades
were used. However, the commenter notes that no basis for this change is given. (Footnotes reference
Attachment 13 and a June 2010 Qualitative Health Risk Assessment for particulate Matter.)

613


-------
Response to Comment 7: The EPA disagrees that the method the EPA uses to monetize PM2.5 benefits
produces unreasonably large estimates. The EPA estimates health benefits below the lowest measured
level (LML), as no evidence suggest a health effect threshold for PM2.5. These methods have withstood
continuous regular reviews by the EPA's SAB. Analyses conducted for the proposed rule demonstrated
that the vast majority of PM2.5 health benefits occurred above the LML. Therefore, this methodological
issue would not have a substantial impact on the overall benefits.

Comment 8: Commenters 17811 and 18436 state that without the proposed rule, "particulate matter
emitted directly from coal-fired power plants was estimated to account for an average of $3.7 billion of
public health damages each year." The commenters go on to state that the OMB review found that from
10/1/99 to 9/30/09 the cost of a PM rule was $7 billion while the estimated benefits range from $19
billion to $167 billion annually. The commenters state that with few pollutants in the air, healthcare
costs will go down. The commenters estimate that the country will save between $13 million and $100
million through reduced premature deaths and healthcare due to illness associated with ozone exposure
when the new ozone standards are finalized. The commenters believe that the cost savings of the
proposed rule represents economics and fewer children suffering asthma attacks, fewer hospitalizations,
less respiratory tract illnesses, improved lung capacity and function for children and healthier infants
and newborns. (Footnotes referencing the cited studies may be found in excerpt 11 for commenter
18436.)

Response to Comment 8: The EPA agrees that the large health co-benefits of this rule resulting from
PM2.5 reductions outweigh the costs.

Comment 9: Commenter 17842 states that the costs associated with the proposed rule will increase
costs for North Dakota in the range of 2 to 4 dollars more a month. The commenter is concerned that the
estimated costs and affects of the proposed rule do not adequately account for other pending regulations
and their collective effect on the industry and economy.

Response to Comment 9: The agency estimates that the nationwide retail electricity price increase
associated with the rule will be 3.1% in 2015, and there will be some variation in this price increase
among different regions. No region of the country, however, is estimated to experience an increase in
price of greater than 6.3%. The agency is cognizant of the estimated price increases. State and local rate
setting agencies are best equipped to deal with the issues concerning higher electricity rates in their
areas. As to analysis including the effects of pending regulations, the agency did not prepare a
cumulative impact analysis to accompany the rule for the following reasons: 1) the various EO
requirements that the agency must comply with require us to estimate impacts specific to this rule; 2)
decision makers and the public need to know the impacts specific to a particular rule in order to judge
the merits of the regulation; and 3) estimates specific to a particular rule are more transparent than those
from a cumulative impact analysis. A cumulative impact analysis lumps several regulations together and
can potentially mask a high-cost/low benefit regulation among other rules that may have large net
benefits. By analyzing each regulation separately, the EPA makes clear statements about what impacts,
costs, and benefits will be generated as a result of this particular regulation. We fold in the impacts of
final regulations and other actions into our baseline as appropriate in order calculate the impacts specific
to a particular rule as accurately and transparently as possible.

This does not, however, mean EPA has failed to consider cumulative impacts of the regulation. The
inclusion of CSAPR and other regulatory actions (including federal, state, and local actions) in the IPM
base case reflects the level of controls that are likely to be in place in response to other requirements
apart from MATS. This base case provides meaningful projections of how the power sector will respond

614


-------
to the cumulative regulatory requirements for air emissions, while isolating the incremental impacts of
MATS. These results are presented in Chapter 3 of the RIA.

Additionally, the Agency does reflect on the broader cumulative impacts of our regulations. In March
2011, the EPA issued the Second Clean Air Act Prospective Report which assessed at the benefits and
costs of regulations pursuant to the 1990 CAA Amendments. The study examines the cumulative impact
of these regulations (found at http://www.epa.gov/air/sect812/febll/summarvreport.pdf). As shown in
the report, the direct benefits from the 1990 CAA Amendments reach almost $2 trillion for the year
2020, a figure that dwarfs the direct costs of implementation ($65 billion). The full report is at
http://www.epa. gov/air/sect812/prospective2 .html.

The direct benefits of the 1990 CAA Amendments and associated programs significantly exceed their
direct costs, which means economic welfare and quality of life for Americans were improved by passage
of the 1990 Amendments. The wide margin by which benefits exceed costs combined with extensive
uncertainty analysis suggest it is very unlikely this result would be reversed using any reasonable
alternative assumptions or methods. This conclusion is likely to also be attributable to this rule as shown
in the RIA.

Comment 10: Commenter 17875 states that rules based on peer-reviewed EPA science will prevent
illnesses such as asthma attacks and other health and environmental impacts from burning coal, which
costs this country upwards of $500 billion each year. Health problems are an especially large burden on
uninsured families, the commenter points out, and the groups with the highest rates of asthma are also
the least likely to be insured. The commenter adds that history shows that less air pollution means a
more efficient workforce and economy, as the EPA estimates the country has gained $21.4 trillion in
health and environmental benefits from clean air programs and saved 4.1 million lost work days and 31
million restricted-activity days.

Response to Comment 10: We agree with the commenter on the potential for this rule to reduce
incidences of asthma and thus reduce health costs to affected populations. The benefits of these
reductions in asthma, along with other benefits, can be found in the RIA for the rule. In addition, we
agree that reductions in air pollution can improve worker productivity and health as shown in the Second
Clean Air Act Prospective Report released in March 2011 which assessed at the benefits and costs of
regulations pursuant to the 1990 CAA Amendments. The study examines the cumulative impact of these
regulations (found at http://www.epa.gov/air/sect812/feb 11 /summaryreport.pdf). As shown in the report,
the direct benefits from the 1990 CAA Amendments reach almost $2 trillion for the year 2020, a figure
that dwarfs the direct costs of implementation ($65 billion). The full report is at
http ://www. epa. gov/air/sect812/prospective2 .html.

Comment 11: Commenter 17884 urges the EPA to reconsider the proposed emission standards. The
commenter believes the rule, and other recently promulgated rules will decrease the use of coal for
electric generation, increase electricity costs by 12-24% in 2016, and cause a net loss of 1.4 million jobs
by 2020. The commenter states that this will decrease disposable income that would have been spent on
food, clothes, heat and air conditioning, and healthcare. (Commenter provided a bulleted list available in
original letter of 8 sets of statistics about different sects of society's income levels and percentage spent
on energy costs.) The commenter points out that these increased energy costs endanger public health and
welfare because of the correlation between wealth and health. The commenter cites multiple legal cases
in which the decision stated the agency must consider safety impacts of regulations. (Whitman v. Am.
Trucking Ass'ns, 531 U.S. 457, 496 (2001) (Breyer, concurring), "[pjreindustrial society was not a very
healthy society; hence a standard demanding the return of the Stone Age would not prove 'requisite to

615


-------
protect the public health.'" See also Am. Trucking Ass'ns v. EPA, 175 F.3d 1027,1052 (D.C. Cir. 1999)
(EPA must consider whether reducing ozone could have negative health effects), rev'd on other grounds
sub nom. Whitman v. Am. Trucking Ass'ns, 531 U.S. 457 (2001); CEIv. NHTSA, 956 F.2d 321, 327
(D.C. Cir. 1992) (agency must consider safety impacts of increasing corporate average fuel economy
standards), and refusing to consider the indirect and negative health and welfare impacts entailed by
increased regulatory compliance costs. Cf. International Union v. OSHA, 938 F.2d 1310, 1326 (D.C.
Cir. 1991) (Williams, J., concurring) ("regulation reduces incomes and thus may exact a cost in human
lives").] The commenter explains that increased living standards and disposable income mean people
can better afford to eat well, heat and cool homes and access healthcare, however, unemployed workers
and their families and people living on fixed incomes can least afford the consequences of higher energy
costs. The commenter cites Brenner (2002) statistics showing strong research in medical population
statistics showing that the higher the social status of a person, the lower the probability of illness and
mortality. A quoted study showed that "Assuming costs are distributed proportional to electricity
consumption, households with income under $15,000 would incur around 43% of the deaths and
households over $50,000 would incur 9% of deaths due to increased energy costs." With unemployment
rates at 9.2% and effective unemployment at nearly 20%, the commenter believes the EPA should
pursue policies to reduce regulatory burden and create jobs and increased energy costs will lead to job
losses and a decrease in general health and welfare. The commenter points out that the EPA's
"appropriate and necessary" analysis does not consider the harm to public health that the proposed rule
represents, nor does the EPA address the potential health disbenefits. The commenter states that low
cost, reliable energy allows people to live longer and better and human health is threatened by the
proposed rule.

Response to Comment 11: The agency's final rule establishes emissions standards that require
reductions of HAP such as Hg, arsenic, and lead and other metals, among other HAP, that are shown to
cause serious injury to exposed populations. We show the benefits of Hg and other HAP emission
reductions, along with the substantial benefits from reductions in emissions of PM, SO2, and other
pollutants in our RIA. Populations that are the focus of EO 12898 will benefit from these reductions as
shown in the RIA. In addition, the increase in electric rates to consumers as shown in the RIA will be
3.1%) on average nationally by 2015, with some consumers in certain regions seeing increases of 6.3%
while other consumers in different regions will see increases of only 1.3%. These increases in electric
rates may not be minimal in some areas of the U.S., but they should be seen in light of the substantial
benefits to health from the emission reductions that will take place across the country due to this rule.

The agency did not prepare a cumulative impact analysis for the rule for the following reasons: 1) the
various EO requirements that the agency must comply with require us to estimate impacts specific to
this rule; 2) decision makers and the public need to know the impacts specific to a particular rule in
order to judge the merits of the regulation; and 3) estimates specific to a particular rule are more
transparent than those from a cumulative impact analysis. A cumulative impact analysis lumps several
regulations together and can potentially mask a high-cost/low benefit regulation among other rules that
may have large net benefits. By analyzing each regulation separately, the EPA makes clear statements
about what impacts, costs, and benefits will be generated as a result of this particular regulation.

This does not, however, mean EPA has failed to consider cumulative impacts of the regulation. The
inclusion of CSAPR and other regulatory actions (including federal, state, and local actions) in the IPM
base case reflects the level of controls that are likely to be in place in response to other requirements
apart from MATS. This base case provides meaningful projections of how the power sector will respond
to the cumulative regulatory requirements for air emissions, while isolating the incremental impacts of
MATS. These results are presented in Chapter 3 of the RIA.

616


-------
Additionally, the Agency does reflect on the broader cumulative impacts of our regulations. In March
2011, EPA issued the Second Clean Air Act Prospective Report which assessed at the benefits and costs
of regulations pursuant to the 1990 Clean Air Act Amendments. The study examines the cumulative
impact of these regulations (found at http://www.epa.gov/air/sect812/febl 1/summaryreport.pdf). As
shown in the report, the direct benefits from the 1990 Clean Air Act Amendments reach almost $2
trillion for the year 2020, a figure that dwarfs the direct costs of implementation ($65 billion). The full
report is at http://www.epa.gov/air/sect812/prospective2.html.

The direct benefits of the 1990 Clean Air Act Amendments and associated programs significantly
exceed their direct costs, which means economic welfare and quality of life for Americans were
improved by passage of the 1990 Amendments. The wide margin by which benefits exceed costs
combined with extensive uncertainty analysis suggest it is very unlikely this result would be reversed
using any reasonable alternative assumptions or methods. This conclusion is likely to also be attributable
to this rule as shown in the RIA.

Comment 12: Commenter 11107 submits an op-ed which must be viewed at

http://www.buffalonews.com/editorial-page/viewpoints/article429987.ece due to copywrite restrictions.
The commenter states that money can be saved by improving air quality and cites (along with
commenter 17408) the National Research Council report that says hidden costs of burning coal were $62
to $156 million for each coal plant. These costs are largely due to S02 emission. The commenter also
cites a study which estimates emission-related damages from coal-fired power plants to be between
$0.02 and $1.57 per kWh generated.

Response to Comment 12: The EPA thanks the commenter for the comments. The agency estimates
substantial benefits from the reduction of HAP and other pollutants from power plants as a result of this
rule, and these results are presented in the RIA for the rule. What the agency describes as "benefits" are
similar to the health and other costs described by the commenter.

Comment 13: Commenter 17254 states that removal of air pollutants will improve air quality and public
health of Georgia communities and cited 79,383 cases of asthma in Fulton County, GA, which earned a
grade of F for the American Lung Association's state of the air report. The commenter expects these
numbers to increase costs to families, communities and tax payers without more air pollution regulation.
The commenter cites Clean Air Task Force as claiming 1,224 deaths caused by local coal-fired power
plants, along with 1,710 heart attacks, 1,770 asthma attacks and 752 cases of chronic bronchitis per year,
at a cost of over $9 billion. The commenter also cited the National Academy of Sciences as saying that
SO2, NOx and PM emissions from coal-fired power plants account for $62 billion in economic damages
in 2005.

Response to Comment 13: The agency expects that the benefits of this rule to Fulton County, GA to be
large, though we have not quantified the impact to this county specifically (it is included in our benefits
analyses in our RIA, of course). The benefits from reductions of HAP and other pollutants due to this
rule will be $37 to $90 billion using a 3% discount rate or $33 to $81 billion using a 7% discount rate
(2007 dollars) in 2015, and this is substantial on its own and relative to the costs of the rule ($9.6 billion
in 2015, in 2007 dollars).

Comment 14: Commenter 17408 discusses the Fisk and Crawford coal-fired power plants in Chicago.
The commenter says the Fisk plant was built in 1903 and rebuilt in 1959. The newest turbines at the
Crawford plant were installed in 1958 and 1961. The commenter says that pollution from these two

617


-------
plants cost neighboring communities $127 million annually in health damages, according to the October
2011 report by Environmental Law and Policy Center. The commenter went on to cite the Natural
Resources Defense Council studies that have shown a high benefit to cost ration from environmental
regulations, with saving in health costs alone surpassing the cost of pollution controls or switching to
cleaner energy sources. The commenter acknowledges that some jobs will be lost, but also created with
the proposed rule. The commenter cites Jonathan Levy's Harvard report which states that 200 lives
could be saved in the Chicago area if pollution were better controlled. The commenter believes that
industry must invest in pollution control because it is a fair cost of doing business. The commenter
points out that healthcare costs are being unfairly transferred to people who may not have insurance and
in the state of Iowa almost two-thirds of children live within 30 minutes of a coal-fired power plant.

Response to Comment 14: The EPA thanks the commenter for their comments. The agency expects
substantial benefits to Chicago and Iowa residents as a result of this rule as HAP and other pollutants are
reduced significantly. Estimates of pollution reduction and associated benefits can be found in the RIA
for the rule. In addition, there may be a small net gain in employment nationally associated with this rule
as shown in the RIA.

Comment 15: Commenter 17409 questions the use of a 7% discount rate for overall benefits. The
commenter sees a discount rate that high as meaning that future benefits lose half their value every 10
years. Because the benefits in question are the health and wellbeing of children, the discount rate means
the worth of children decreases by half every 10 years. The commenter suggests that when calculating
for generational benefits, the EPA should use a 2.5% discount rate as used when dealing with climate
change.

Response to Comment 15: The preferred discount rate for benefits estimation by the agency is 3%,
not 7%. This is explained in the RIA for the rule, where the benefits analysis for this rule is presented.
Estimates of benefits with a 7% discount rate are prepared in adherence to OMB Circular A-4, which we
must follow in preparing the RIA for a rule such as this one, and that calls for presentation of costs and
benefits discounted at both 3 and 7% rates.

Comment 16: Commenter 17409 states that the cost of pollution is being borne by children and other
vulnerable people and reports that 1 in 11 children has asthma, resulting in a $56 billion expenditure
making it so that we can't afford not to clean our air. The commenter goes on to discuss the B.L.

England plant, which produces 29 pounds of Hg annually and is built on a bay. The commenter states
that 1/70 of a teaspoon of mercury is enough to contaminate a 25 acre lake. The commenter also cites
the February 2011 Harvard Medical Study showing public health costs related to coal are a $175 to $500
billion annually.

Response to Comment 16: The EPA thanks the commenter for the comment. We agree that polluted air
can impose detrimental health outcomes such as asthma or other ailments, and the reductions of HAP
and other pollutants associated with this rule will lead to improved public health and thus reduced health
costs for asthma sufferers. In addition, reductions in Hg will also improve health and ecosystems, as the
agency shows in the RIA for this rule.

Comment 17: Commenter 18432 supports the proposed standards as fair and equitable and believes
communities will benefit from the reduction in air pollution no matter if the regulated facilities choose to
add pollution controls, switch fuels or shut down and pursue renewable energy sources.

618


-------
Response to Comment 17: We agree with the commenter that the pollutant reductions from this rule
will be fair and equitable to the extent we can require them, and do agree that the benefits of the rule will
be large regardless of how the reductions are obtained. However, we are mindful of the need to
minimize the economic impacts and costs of this rule along with the need to maximize benefits when
permissible under the CAA.

Comment 18: Several commenters (18432, 18435, 18541) urge the EPA to proceed with finalizing the
proposed rule without changing it, as it will prevent more Americans and especially children from
premature death or chronic illness.

Response to Comment 18: The EPA thanks the commenter for their comments. We have reviewed
public comments on the proposed rule as required by law and issued this final rule in light after
considering and responding to such comments.

Comment 19: Multiple commenters (18541, 19536, 19537, 19538) say that the full cost of the regulated
pollutants is not adequately reflected in electricity costs or the cost-benefit analyses. The commenters
state that the cost of the pollution emitted by EGUs is being unfairly placed on the public instead of the
polluting source. The commenters considered the EPA analyses insufficient because they do not assess
impacts on wildlife and ecosystems, as they should be under the Biological Assessment, ESA and CAA.
The commenters urge that analysis be broadened to include valuation of these impacts, even if the
studies are limited.

Response to Comment 19: The agency recognizes the need to include the effects on wildlife and
ecosystems in the benefits analyses for our rules. We include these benefits to the extent that it is
credibly possible according to our understanding of the relevant science in our analyses, and this is
shown in the RIA for this rule.

Comment 20: Commenter 18961 cites a recent study by the United Nations Environment Program
which estimated that a reduction by at least 50% of Hg emissions from current levels provides societal
benefits more than double the implementation cost by the year 2020. The commenter reports that the
estimate is based on the value of averting human neurotoxic damage, loss of earnings, loss of education
and opportunity costs. The report showed that even a reduction of 30 to 50% would produce benefits
beyond the costs.

Response to Comment 20: The EPA thanks the commenter for their comments on Hg benefits. Our
current estimate of Hg benefits for this rule is $4 to 6 million using a 3% discount rate and $0.5 to $1
million using a 7% discount rate (2007 dollars) annually in 2015 as shown in the RIA for the rule. We
intend to refine our estimates of Hg benefits over time and given the availability of new studies. This
rule as a whole will provide substantial benefits based on the expected reduction in reductions of HAP
such as Hg and other pollutants.

Comment 21: Several commenters (19536, 19537, 19538) report that the Minnesota Pollution Control
Agency and Legislative Commission on Minnesota Resources estimate the economic benefits of reduced
Hg at $212 million based on 50% reduction. This study understates the total economic benefits,
according to the commenter, because it does not take into account factors such as improved public
health. Commenters also quote the Harvard School of Public Health estimate that health related
economic impact of Hg pollution exceeds $5.5 billion and estimates the costs of lost productivity due to
reduced IQs from Hg pollution at $1,625 billion, the costs of mental retardation due to Hg emission at
$361 million and the cost of excess cardiovascular disease from Hg exposure at $3.54 billion.

619


-------
Commenters state that a decline in angling of just 25% due to lake and stream fouling by Hg could cost
Minnesota $706 million annually and jeopardize 25,955 jobs in the state. In Wisconsin, the costs of
water fouling from Hg could cost $516 million annually and jeopardize 21,459 jobs. Commenters
believe the proposed rule will help improve regional haze and sulfate deposition, lessen acidification of
lakes and streams and decrease concentrations of lung damage due to air pollution.

Response to Comment 21: The EPA thanks the commenters for the results of these studies, and agrees
in general with the commenters' conclusions on reduced regional haze, sulfate deposition and lake
deacidification, and improved human health related to the reduction of HAP and other pollutants related
to this rule. For more information on these types of impacts and how the agency's benefits analysis
considered them, refer to the RIA for the rule.

620


-------
6K - Impacts/Costs: Health Co-Benefits

Commenters: 12267, 14115, 15002, 16404, 16469, 16630, 16826, 16849, 17157, 17254, 17283, 17381,
17408, 17409, 17620, 17621, 17623, 17637, 17638, 17639, 17648, 17676, 17681, 17689, 17702, 17707,
17709, 17715, 17716, 17718, 17727, 17730, 17731, 17734, 17736, 17751, 17753, 17754, 17755, 17756,
17757, 17761, 17765, 17766, 17775, 17799, 17800, 17805, 17811, 17813, 17816, 17843, 17848, 17852,
17855, 17868, 17871, 17875, 17880, 17882, 17884, 17903, 17912, 17916, 17919, 17921, 17930, 17931,
18018, 18022, 18027, 18029, 18033, 18034, 18037, 18039, 18421, 18425, 18428, 18432, 18435, 18436,
18438, 18477, 18478, 18487, 18488, 18498, 18500, 18501, 18502, 18541, 18759, 18961, 18963, 19114,
19121, 19145, 19580, 19536/19537/19538, 18932, 18023

1. Benefits of the proposed rule outweigh compliance costs.

Comment 1: Several commenters (15002, 17648, 17921, 18541) agree with the EPA that health
benefits of the proposed rule far outweigh the costs incurred by industries to comply. Commenters
15002 and 17468 suggest that the estimates of benefits are underestimated due to the lack of
quantification of benefits due to expected reductions in ground-level ozone. Commenter 17648 argues
that the EPA employed peer-reviewed and conservative methodology in preparing the benefit-cost
analysis, and argues that even without the rule, the development of stable and lower-priced natural gas
supplies will result in the closure of obsolete coal plants. Commenter 17648 further states that critics of
the EPA's benefit-cost analysis do not understand the principles of economic impact analysis. The
commenter states that despite criticism, the inclusion of PM2 5 co-benefits as part of the monetized
benefits are appropriate because HAP are part of the PM2.5 fraction. Commenter 15002 points out that
recent data estimate that almost 120 Americans live in counties where NAAQS are not met, though the
commenter considers these standards insufficient to protect health. Commenter 15002 further notes that
PM2.5 reduction is projected to occur as the result of improved trapping of primary particulates and
formation of secondary particulates created by condensation of oxides of sulfur and nitrogen with other
chemicals or particles in the atmosphere. According to the commenter, these reductions are expected to
result in a substantial reduction in several diseases, and improve overall mortality. Commenter 17648
points out several benefits not quantified by the EPA, such as (1) young women who now avoid eating
fish due to concerns of Hg; (2) reductions in synergistic and additive effects of the pollutants whose
emissions will be reduced; (3) enhanced ecosystem services; (4) reduced acidification of ecosystems; (5)
elimination or reduction of a variety of unquantified health impacts, including respiratory effects,
resulting in increased hospital and emergency room visits, respiratory symptoms, airway hyper-
responsiveness, airway inflammation and lung function; (6) reduction of impacts of heavy metals; and
(7) secondary impacts such as economic benefits to downwind businesses. Commenter 17921
recommends two studies regarding the benefits of reducing Hg emissions that could be used to better
estimate health benefits of the rule: (1) Rice, G., & Hammitt, J. K. (2005). Economic valuation of human
health benefits of controlling mercury emissions from U.S. coal-fired power plants; and(2) Trasande, L.,
Landrigan, P. J., & Schechter, C. (2005). Public health and economic consequences of methylmercury
toxicity to the developing brain. Environmental Health Perspectives. doi: 10.1289/ehp.7743.

Commenter 18541 argues that the benefits to wildlife were not fully accounted for, saying that the EPA
should formally consult the U.S. Fish and Wildlife Service and the National Marine Fisheries Service to
set the standards strictly enough to protect wildlife and ecosystem health. Commenter 17648 suggests
that the agency overestimated the costs of compliance, partly due to technological innovation that is not
considered. The commenter provides the example of the acid rain program, in which according to the
RIA, the cost of implementing the program was 83% lower than original estimates.

621


-------
Response to Comment 1: This rule is expected to achieve important non-Hg HAP benefits. However,
monetization of non-Hg HAP benefits is limited by currently available data and methods. In summary,
monetization of the benefits of reductions in cancer incidences requires several important inputs,
including central estimates of cancer risks, estimates of exposure to carcinogenic HAP, and estimates of
the value of an avoided case of cancer (fatal and non-fatal). Due to methodology and data limitations,
we did not attempt to monetize the health benefits of reductions in HAP in this analysis. Instead, we
provide a qualitative analysis of the health effects associated with the HAP anticipated to be reduced by
these rules. The EPA disagrees that the health benefits of non-Hg HAP could never be measured. A well
designed epidemiological study could measure these benefits. The EPA remains committed to
improving methods for estimating HAP benefits by continuing to explore additional concepts of
benefits, including changes in the distribution of risk. Quantitative estimates of these benefits are
provided to the extent possible, and our limited ability to monetize these benefits does not indicate that
they are non-existent or less important.

Our treatment of these benefits follows guidance set by OMB Circular A-4 (pp. 26-27, available at:
http://www.whitehouse.gov/omb/circulars a004 a-4/):

"Sound quantitative estimates of benefits and costs, where feasible, are preferable to qualitative
descriptions of benefits and costs because they help decision makers understand the magnitudes of the
effects of alternative actions. However, some important benefits and costs (e.g., privacy protection) may
be inherently too difficult to quantify or monetize given current data and methods. You should carry out
a careful evaluation of non-quantified benefits and costs. Some authoritiesrefer to these non-monetized
and non-quantified effects as "intangible.""

It is also in line with EPA's Guidelines for Preparing Economic Analyses (p. 11-3, available at:
http://vosemite.epa.gov/ee/epa/eed.nsf/pages/Guidelines.htmn.

"Benefits and costs that cannot be monetized should, if possible, be quantified (e.g., expected number of
adverse health effects avoided). Benefits and costs that cannot be quantified should be presented
qualitatively (e.g., directional impacts on relevant variables)."

2. Benefits of the proposed rule do not outweigh compliance costs.

Comment 2: Many commenters (14115, 16469, 17638, 17639, 17681, 17702, 17716, 17730, 17731,
17751, 17753, 17754, 17756, 17757, 17761, 17765, 17799, 17800, 17813, 17855, 17868, 17884, 17919,
17930, 17931, 18033, 18034, 18037, 18428, 18488, 18963, 19121, 19580, 18023) suggest that the
benefits of the proposed rule do not outweigh the cost. Multiple commenters (14115, 16469, 17638,
17681, 17702, 17716, 17730, 17731, 17751, 17754, 17757, 17761, 17765, 17800, 17813, 17855, 17868,
17930, 18033, 18034, 18037, 18428, 18488, 18023) state that most of the benefits would be due to
PM2.5 co-benefits, and that the Hg benefits would amount to $6 million or less, far below the estimated
$10.9 billion annual costs. Commenter 18037 states that regulations focus on incrementally smaller
emission reductions and with increased costs, and thus regulations are less and less justified. Several
commenters (17639, 17799, 17912) state that the benefits of the proposed rule do not justify the costs
since the predicted risks for air toxins are approaching or are less than 1 in 1 million and fine particulate
matter is regulated under the ambient air quality standards of the CAA. Commenter 17799 argues that
the analysis of chromium emissions was flawed, in that hexavalent chromium, a carcinogen, may be
converted to less toxic forms by the time it reaches the target population; thus the corresponding
increased cancer risk from 0.33 (lifetime cancer risk to average person) to 0.330001 "is so minimal that
it could not be observed in any health effects study that might be conducted." Similarly, commenter

622


-------
18034 states that the cancer risks from nickel and hexavalent chromium emissions are within limits
previously considered acceptable by the EPA. Commenter 17799 also points out that the "EPA states
that non-cancer risks for the non-mercury HAP for coal units never exceeded a non-cancer hazard index
of 0.5 whereas the level of concern would be 1.0... [the EPA's definition of hazard index states that]
exposures equal to or below [a hazard index] of 1.0...likely will not result in adverse non-cancer health
effects over a lifetime of exposure and would ordinarily be considered acceptable." Several commenters
(17639, 17754, 17757) point out that the proposed rule duplicates existing regulations and will exhaust
state and federal government resources.

Response to Comment 2: The EPA disagrees with commenters that the benefits of the rule do not
exceed the costs. The benefits of this rule encompass the benefits of Hg reductions and co-benefits to
health achieved via PM2.5 reductions. As the analyses presented in the RIA for the rule show, the
benefits outweigh the costs by a large margin. Although the monetized benefits of reducing Hg
emissions are not large, those benefits are also not equally distributed across the population. As the
sensitivity analysis shows, some populations, including low-income African Americans and some
Native American populations, may receive a disproportionate benefit, and the distributional aspects of
the benefits may help to justify the costs of the rule. Furthermore the analysis depended on using a less
sensitive endpoint (IQ) of neurological impacts of Hg exposure as noted by the SAB which leads to
underestimation of the benefits. Additionally many other impacts of Hg emissions were not quantified
including impacts on ecosystems and wildlife especially fish, birds both fish and insect eating, and
mammals. Other HAP controlled by the MATS rule were likewise not quantified due to data, resource
and methodological limitations. Even if we were able to fully monetize the public health benefits of
reducing exposure to Hg and other HAP, it is likely that the PM benefits would continue to dominate the
total monetized benefits due to the size of the exposed population and the severity of the associated
health effects. Despite our inability to provide monetized benefits of HAP emission reductions, the total
monetized benefits exceed the estimated costs of the rule by a substantial margin, even when taking
uncertainty into account.

Consideration of PM2.5 health co-benefits expected as a result of direct PM2.5 and S02 emission
reductions is directed by OMB Circular A-4 (p. 26, available at:
http://www.whitehouse.gov/omb/circulars a004 a-4/):

"Your analysis should look beyond the direct benefits and direct costs of your rulemaking and consider
any important ancillary benefits and countervailing risks. An ancillary benefit is a favorable impact of
the rule that is typically unrelated or secondary to the statutory purpose of the rulemaking (e.g., reduced
refinery emissions due to more stringent fuel economy standards for light trucks) while a countervailing
risk is an adverse economic, health, safety, or environmental consequence that occurs due to a rule and
is not already accounted for in the direct cost of the rule (e.g., adverse safety impacts from more
stringent fuel-economy standards for light trucks)."

It is also directed by the EPA's Guidelines for Preparation of Economic Analyses (p. 11-2, available at:
http://vosemite.epa.gov/ee/epa/eed.nsf/pages/Guidelines.htmn:

"An economic analysis of regulatory or policy options should present all identifiable costs and benefits
that are incremental to the regulation or policy under consideration. These should include directly
intended effects and associated costs, as well as ancillary (or co-) benefits and costs."

In line with this guidance, the EPA estimates all of the anticipated costs and benefits associated with a
regulatory action, to the extent feasible. We further note that if we were able to fully monetize all of the

623


-------
benefit categories, the benefits would exceed the costs by an even greater amount than we currently
estimate.

3. Methods used to calculate benefits.

Comment 3: Several commenters (17623, 17639, 17799, 18428, 18963) suggest the EPA is
overestimating the benefits of Hg emission reductions associated with the rule. Commenters 17623 and
18963 state that recent estimates of emissions from coal-fired units show a substantial reduction in Hg
from 2000 to present. Commenters 17639 and 17799 quote a risk science consulting firm statement that
the health benefits attained by Hg reductions could "never be measured or observed in real life."
Commenter 17799 argues further that the "public health benefits from HAP reductions are minimal,"
stating that the rule would have a negligible impact on mercury exposures in most of the U.S. because
Hg exposures are dominated by non-U. S. sources. Commenter 18428 suggests that the improvement of
500 IQ points across the entire U.S. population estimated in the benefits calculations is negligible and
should not be considered. Similarly, commenter 17623 states that for Hg, some of the EPA's health
effects could not be monetized, such as IQ improvements. Commenter 17799 states that the EPA
attempts to justify regulation of non-Hg HAP based on environmental benefits, which is "not a criterion
Congress gave EPA as a basis for regulation under 112(n)(l)(A) and therefore is an irrelevant
consideration."

Response to Comment 3: The EPA disagrees with commenters that the benefits of Hg emission
reductions associated with this rule were overestimated. In fact, the EPA believes that the estimates
presented in the RIA are an underestimate because the EPA was not able to analyze the impacts using
the most sensitive endpoints for human health. According to the SAB's review of the TSD for this rule
"The loss of IQ points is likely to underestimate the impact of reducing methyl mercury in water bodies.
The reason is that IQ score has not been the most sensitive indicator of methylmercury's neurotoxicity in
the populations studied. As noted in the TSD, in the Faroe Island study the most sensitive indicators
were in the domains of language (Boston Naming), attention (continuous performance) and memory
(California Verbal Learning Test), neuropsychological tests that are not subtests of IQ tests and are not
highly correlated with global IQ. In the Seychelles study, the Psychomotor Development Index has been
most sensitive measure and, while this is a component of the Bailey Scales of Infant Development, it is
not highly correlated with cognitive measures."

The EPA also would point out that the estimates only use self-caught freshwater fish, including saltwater
fish consumption would increase the estimates. In addition many of the benefits of Hg reductions were
not quantified including the many significant adverse impacts to wildlife and ecosystems.

Comment 4: Several commenters (17702, 17751, 18018, 18033, 18500) express concerns that the
method the EPA used to monetize benefits produces unreasonably large estimates. Commenter 18033
cites the EPA's counting of mortality estimates for PM2.5 exposures below the lowest measured level
(LML) as a major concern. Commenter 18033 points out that the EPA has never set a NAAQS at a level
as low as the LML because the EPA believed that it was not required to protect public health; however,
the commenter argues that using the LML in this rule drastically overestimates mortality associated with
low levels of PM2.5

For several commenters (17702, 18018, 18500), the specific concern is that using the value of statistical
life (VSL) based on the public's willingness to pay (WTP) results in a VSL of $8 million per person.
The VSL is used regardless of the time a death is postponed, while the annual value for GDP per person
is around $42,000. Commenters point out that even if the death is postponed for 10 years by the

624


-------
proposed rule, the GDP value would be around 5% of the EPA VSL. Commenter 18018 discusses
calculating the VSL to estimate the value of remaining life, so that a 2-year-old would have a higher
VSL than an 80-year-old, since people with shorter life expectancy may be less willing to devote
resources to reduce their risk of premature death. Commenter 17751 states that the mortality risk
reduction is derived from a meta-analysis of 26 contingent valuation and labor market studies from 1982
to 1991, but does not adequately discuss the need to improve WTP valuations or present limitations of
the estimate. For example, commenter 17751 points out that the EPA does not cite studies critical of the
meta-analysis or the fact that many labor market studies in the meta-analysis reflect wage differentials
which arise from differences between occupations in terms of risk of death in accidents. Commenter
17751 questions the EPA's lack of consideration of whether to apply values derived from contexts in
which risk is immediate to environmental policy context in which risk involves long-term consideration.
Commenter 17751 also points out the lack of consideration of the importance of selection bias in the
meta-analysis. Commenter 17751 states that the EPA's chosen value for mortality risk reduction is
based on an average of findings, but the studies are not a random sample of studies but rather those
selected by the analysis author to satisfy certain criteria not revealed. The commenter further states that
in comparison to the EPA's simple average of 26 studies that yielded a value of $6.2 million (2000
dollars), one comparative study (Giles, et al.) found that correction for publication selection bias yielded
a value of $2.74 million (2000 dollars). The commenter requests that the EPA include a discussion of
alternative meta-analyses of WTP studies. The commenter recommends the following:

1.	Bellavance, F., Dionne, G., Lebeau, M. 2009. The Value of a Statistical Life: A meta-analysis
with a mixed effects regression model. Journal of Health Economics 28: 444-464.

2.	Bowland, B.J., Beghin, J.C. 2001. Robust Estimates of the Value of a Statistical Life for
Developing Countries. Journal of Policy Modeling 23: 385-396.

3.	De Blaeij, A., Florax, R.J.G.M., Rietveld, P., Verhoef, E. 2003. The Value of Statistical Lifein
Road Safety: A meta-analysis. Accident Analysis andPrevention35: 973-986.

4.	Dionne, G., Michaud, P.C. 2002. Statistical analysis of value-of-life estimates using hedonic
wage method. Working Paper 02-01. Risk Management Chair, HEC Montreal.

5.	Kochi, I., Hubbell, B., Kramer, R. 2006. An Empirical Bayes Approach to Combining and
Comparing Estimates of the Value of a Statistical Life for Environmental Policy Analysis.
Environmental and Resource Economics 34:385-406

6.	Lindhjem, H., Navrud, S., Braathen, N.A. 2010. Valuing Lives Saved From Environmental,
Transport and Health Policies: A meta-analysis of stated preference studies. Working Party on
National Environmental Policies, OECD, February.

7.	Liu, J.T., Hammitt, J.K., Liu, J.L. 1997. Estimated Hedonic Wage Functions and Value of
Statistical Life in a Developing Country. Economics Letters 57(3):353-358.

8.	Miller, T.R. 2000. Variations Between Countries in Values of Statistical Life, Journal of
Transport Economics and Policy 34(2): 169-188.

9.	Giles, Doucouliagos and Stanley have statistically assessed the effect of selection bias on meta-
analyses of the value of mortality risk reduction, and have found that correction for selection bias
reduces the average value by 70 to 80 %.

Response to Comment 4: The EPA disagrees with commenters that the method the EPA uses to
monetize PM2.5 benefits produces unreasonably large estimates. The EPA estimates health impacts of
PM2.5 below the LML, as evidence suggests that there is no discernable threshold for long-term PM2.5
mortality (e.g., Roman et al. 2008, Schwartz et al. 2008, Krewski et al. 2009). The EPA methods for
quantifying health benefits of emission reductions are based on the best available peer-reviewed science
and methods that have withstood scrutiny from the EPA's independent SAB, the National Academy of
Sciences, and continuous interagency review. Note that NAAQS are set at a level deemed by the EPA

625


-------
Administrator to be protective of public health within an adequate margin of safety, and are not set at a
level of zero risk. Further, analyses conducted for the proposed rule demonstrated that while 30% occur
above the LML (10 ug/m3) of the Laden et al. (2006) study, 86% of PM2.5 health benefits occurred
above the LML (7.5 ug/m3) of the Pope et al. (2002) study. We note that a more recent extended re-
analysis of the Pope et al. (2002) study found significant health impacts of PM2.5 down to a lower LML
(5.8 ug/m3; Krewski et al. 2009). Therefore, we believe estimation of health effects below the LMLs in
the Laden et al. (2006) and Pope et al. (2002) study is justified. However, we do note that as we model
mortality impacts among populations exposed to levels of PM2.5 that are successively lower than the
LML of each study our confidence in the results diminishes. Therefore, we continue to include statistics
in the final RIA (as was done in the RIA for the proposed rule) showing the percentage of health impacts
occurring above these levels for readers to understand the effect of this methodological decision.

With respect to the method the EPA uses to monetize benefits, according to standard welfare economics,
the economic value of a reduction in mortality risk is the maximum amount an individual would be
willing to pay for it. The VSL is a representation of WTP values in that it captures the average rate at
which people are willing to pay for very small changes in mortality risks (say, 1 in 10,000 per year). The
VSL does not represent the value of avoiding or postponing certain death for any particular individual.
By convention, estimates of these willingness-to-pay values are typically normalized by the change in
risk. For example, if on average workers are willing to sacrifice $800 in additional annual pay for jobs
that have a reduced fatality risk of 1 in 10,000 per year, then the estimated VSL would be $800 x 10,000
= $8 million. The estimated annual WTP per exposed individual for the average risk reduction under this
rule is well below the annual value for GDP per person of $42,000.

On calculating VSL to estimate the value of remaining life, the EPA has explored the issue of remaining
life expectancy and its potential effect on WTP in the past and has, in fact, received guidance from the
SAB on the matter. The SAB's full response is available in their October 12, 2007 guidance to the EPA
on valuing mortality risk reductions, pages D-10 and D-l 1. To summarize, the SAB points out that
economic theory is ambiguous on how people's willingness to pay to reduce mortality risks should
change over their lifetime, leaving it, therefore, as an empirical matter. The judgment of the SAB,
however, is that the empirical literature is not advanced enough to provide clear guidance on how age
and health status affect willingness to pay to reduce mortality risks. The recommendation of the SAB is
to use an age-independent valuation of mortality risk reductions.

.http://vosemite.epa.gov/sab/sabproduct.nsf/02ad90bl36fc21ef85256eba00436459/4128007E7876B8FQ
852573760058A978/$File/sab-08-001.pdf

Regarding the limitations of WTP, the 26 studies underlying the EPA's guidance for WTP for mortality
risk reductions come from Viscusi, 1992, which describes the selection criteria. Viscusi, 1992, is
described as the source for these studies when the EPA originally used the set in The Benefits and Costs
of the Clean Air Act: 1970 to 1990 (US EPA, 1997, page 1-3). Most of the studies in this set of literature
are based on wage differentials for workplace risks. Although these estimates cannot be taken as precise
values for mortality risk reductions from environmental policies, their usefulness for informing
environmental policy analysis has been recognized by the Environmental Economics Advisory
Committee of EPA's SAB (SAB-EEAC) (US EPA SAB 2000). The difficulties and limitations of these
estimates for environmental policy are described in our Guidelines for Preparing Economic Analyses
(US EPA 2010).

The agency has examined multiple meta-analyses published in the economics literature since
promulgating our guidance in the Guidelines for Preparing Economic Analyses in 2000. This effort
includes a report from leading experts in statistical meta-analysis (USEPA 2006). The agency has

626


-------
consulted with the SAB-EEAC on how to evaluate and apply meta-analyses, and how the agency should
revise its own meta-analysis methodology. Although the SAB-EEAC did not recommend that the EPA
adopt any of the existing meta-analyses, the Committee made several recommendations on how the
agency should conduct its own analysis, including details on selection criteria, and how to incorporate
results from different methods and in different contexts (US EPA SAB 2007, 2011). Based on these
advisories the EPA is now reviewing the existing literature and developing methods to inform new
guidance on valuing reductions in mortality risks in agency economic analyses. This effort will include
considerations of many potential biases in the resulting estimates, including issues such as the
publication bias concern described in the Giles, et al. study.

Comment 5: Several commenters (16469, 18500, 17621, 17283) suggest that the uncertainty analysis is
insufficient. Commenter 17621 argues that "the only quantitative uncertainties presented are those for
the particular dose-response estimates taken from the two studies cited by EPA. Other uncertainties are
listed in several tables, with no attempt to quantify them." Several commenters (16469, 17621, 17283,
18500) suggest that the differential toxicity of PM species needs to be considered when calculating
potential health benefits of emissions reductions to fully assess the impacts, and this issue should be
considered in the uncertainty analyses.

Response to Comment 5: The EPA disagrees with these commenters that the uncertainty analysis is
insufficient. We conduct several different types of analyses that examine the effects of the most
important methodological choices on results. For example, we estimate mortality impacts using health
effect estimates garnered from an EPA-sponsored expert elicitation (Roman et al. 2008). The experts in
the elicitation produced a range of effect estimates that span from smaller than the effect estimate by
Pope et al. (2002) and larger than the effect estimate by Laden et al. (2006). The expert elicitation is one
method of characterizing uncertainty in PM-related mortality. Although we are unable to quantify the
impact of all sources of uncertainty, we examine the effect of assuming a health effect threshold at the
lowest measured level in the epidemiology studies. We also conduct sensitivity analyses examining
different income elasticity assumptions. The uncertainties that are not quantifiable are listed in tables to
acknowledge their possible influence on estimated benefits.

4. Criteria co-benefits should not be considered in analysis.

Comment 6: Many commenters (17702, 17716, 17751, 17753, 17754, 17765, 17775, 17799, 17813,
17855, 17912, 17919, 18034, 18428, 18488, 18498, 18963, 19114, 18023) question the use of criteria
co-benefits to justify HAP regulation. They suggest that the inclusion of co-benefits is contrary to the
original intention of reducing Hg emissions, because the reductions of PM2.5 emissions can be expected
to be achieved through other regulations. Commenter 17765 states that the little incremental health
benefits from the proposed rule do not justify its economic impacts. Commenter 17716 estimates that
without co-benefits, the "net benefits" of the proposed rule would be negative $42,000,000,000 to
negative $130,000,000,000. Commenters 17716 and 17799 question the intent of the CAA or legislative
history to have co-benefits from criteria pollutants regulated under a different CAA regulatory scheme
serve as the driving force to curb HAP emissions through MACT regulation. Commenters 17754 and
18034 acknowledge that benefits beyond those from Hg emissions reductions will be up to $130 billion
annually, but again, since these benefits come from co-benefits from reducing PM2.5 emissions, consider
the cost-benefit analysis supporting regulation of Hg emission to be flawed. Commenter 17775 attached
a memo by Dr. Anne Smith providing technical comments on the RIA for the proposed rule and
discussing the use of co-benefits. The commenter states that PM25 benefits are attributable to the control
of HAP acid gases, yet public exposures to HAP acid gas emissions were found to be far below the
reference concentration levels for those HAP, which the EPA defines as being without an appreciable

627


-------
risk. Commenters 17912 and 17919 question the EPA's legal justification for the proposed rule that
argues non-Hg HAP must be regulated. Commenter 17719 points out that there is a separate program for
the regulation of PM25, and the EPA does not address whether there is a less expensive way to achieve
the same benefits attributed to the proposed rule, such as those included in the PM2.5 program.
Commenter 17719 believes this is pertinent, since the EPA is mandated to find the most cost effective
solution for regulatory priority.

Multiple commenters (18023, 16469, 17621, 17718, 17751, 17761, 17800, 17816, 17919, 17855, 18033,
18963) find the EPA calculation of PM25 NAAQS benefits to be incorrect because the commenters say
the EPA is either double counting potential benefits of the NAAQS program in the calculation of
benefits from the proposed rule, or relying on the supposition of health benefits from any PM reduction
anywhere. Commenter 18023 considers this an unfounded supposition that both the EPA and the EPA
science advisors have rejected as too uncertain to adopt when setting PM25 NAAQS. Commenter 18023
points out that if these PM25 benefits are disregarded, the monetized benefits for the proposed rule drop
to $0,576 billion, from C02 reductions and HAP reductions. The commenter states that this change
means the cost of the proposed rule would exceed the monetized HAP benefits by a factor of at least
1,800.

Comment 7: Numerous commenters (16469, 16849, 17638, 17681, 17702, 17730, 17799, 17848,
17919, 18018, 18033, 18500, 18023) estimate that 90-99% of the benefits the EPA attributes to the
proposed rule actually come from PM2 5 reductions from reduced emissions of S02, which is not a HAP,
and did not indicate benefits from acid gas reductions. Commenters believe the same benefits would be
delivered by other CAA rulemakings including PM, S02 and ozone NAAQS and the Cross-State Air
Pollution rule. Commenter 16849 points out the limitations of the proposed solutions due to the fact that
multiple emission control equipment do not always work together harmoniously following a retrofit.
Commenter 17702 believes that proposing air toxic limits more restrictive than those envisioned under
CAMR would result in greater costs without commensurate benefits to the public. Commenter 17730
believes the proposed rule should be based on the rule's ability to reduce the emissions of HAP that
provide a public health benefit after imposition of the CAA requirements and the associated public
health and environmental benefits from those reductions. Commenter 17848 points out that the
estimated health benefits from the proposed rule were compared with the estimated health benefits from
the Transport Rule S02 reductions and the number of avoided outcomes per 1,000 tons of S02 reduction
is nearly identical for 2014 and 2016. However, the commenter points out that ambient PM2 5 levels
should decrease between those 2 years as a result of the Transport Rule reductions. Therefore the
commenter says that since baseline emissions should be lower after Transport Rule implementation, a
smaller quantity of S02 reductions would be achieved by the proposed rule. Several commenters (18023,
17638, 17681) state that over 80% of the estimated PM25 health benefits are assumed to occur in areas
that meet the levels the EPA is currently considering for a new PM2 5 NAAQS, and thus should not be
considered under this rule. Commenter 18500 cautions that the EPA's monetizing benefits estimate due
to C02 reductions should be considered carefully because a of the questions associated with climate
change.

Comment 8: Many commenters (16469, 17621, 17623, 17637, 17681, 17702, 17751, 17761, 17775,
17800, 17855, 17884, 17919, 18033, 18963, 18023) note that the PM2.5 co-benefits to which many of the
proposed rule's benefits are attributed are mainly based on emission reductions in areas already
achieving the annual PM2 5 NAAQS or are being addressed by other rules. As such, commenters 17623
and 17855 ask that the EPA explain what additional PM benefits are derived from the proposed rule.
Commenter 17681 considers the costs of the proposed rule to be very low and not outweighed by the
"contrived" benefits. Commenters 17919 and 18023 state that the NAAQS set a level of PM2 5 that the

628


-------
EPA found to be sufficient to public health and welfare with an adequate margin of safety and areas in
attainment with this level are already safe from health risks. Some commenters (17855, 17621, 17637,
17718, 17761, 18963) state that attainment of the NAAQS for PM25 is already being addressed on both
the local and regional basis through SIPs and CSAPR. Commenter 18033 points out that the EPA "is
preparing to propose a new [lower] PM25 NAAQS...[but] until it does so...it is inappropriate for EPA to
adopt rules based on claimed benefits below the current NAAQS level." Commenter 17621 requests that
the EPA clearly articulate the individual benefits to all of its pending air rules to clarify the issue of
double counting benefits.

Comment 9: Commenter 17876 states that the EPA's attribution of 90% of the health benefits under
this rulemaking to justify the further regulation of PM is problematic based on recent studies. See, e.g.,
Koop, Gary, Ross McKitrick and Lise Tole (201 0) "Air Pollution, Economic Activity and Respiratory
Illness: Evidence from Canadian Cities 1974-1994" Environmental Modeling and Software 2010, doi:
10.1 016/j.envsoft.201 0.01.01 0; Gary Koop, Lise Tole, "Measuring the Health Effects of Air Pollution:
to what extent can we really say that people are dying from bad air?" Journal of Environmental
Economics and Management (2004), 30-54.

Comment 10: Commenter 18023 believes the EPA's flawed cost-benefit analyses makes it difficult to
assess the proposed rule under UMRA and EO 12866, which require the EPA to assess both the costs
and benefits of the proposed rule. The commenter believes the EPA is double counting benefits
associated with PM2.5 in its RIA, and therefore has failed to meet its obligations to promulgate a
regulation that imposes the least burden on society.

Response to Comments 6 -10: On inclusion of PM25 health co-benefits, the EPA disagrees with
commenters that PM2.5 health co-benefits should be excluded in the estimation of benefits expected by
MATS. Accounting for ancillary benefits is standard practice in benefit-cost assessment since these
benefits are a consequence of the rule, regardless of the rule's intended purpose (as noted also by
commenter 17768). As such, the EPA estimates all of the anticipated costs and benefits associated with a
regulatory action, to the extent feasible, for the purpose of determining the likely impacts, not to justify
an action. This rule is expected to achieve substantial PM25 health benefits resulting from primary PM
and S02 emission reductions, and these co-benefits are thus an important category to quantify.

Consideration of ancillary benefits in benefit-cost analysis is directed by OMB Circular A-4 (p. 26,
available at: http://www.whitehouse.gov/omb/circulars a004 a-4/):

"Your analysis should look beyond the direct benefits and direct costs of your rulemaking and consider
any important ancillary benefits and countervailing risks. An ancillary benefit is a favorable impact of
the rule that is typically unrelated or secondary to the statutory purpose of the rulemaking (e.g., reduced
refinery emissions due to more stringent fuel economy standards for light trucks) while a countervailing
risk is an adverse economic, health, safety, or environmental consequence that occurs due to a rule and
is not already accounted for in the direct cost of the rule (e.g., adverse safety impacts from more
stringent fuel-economy standards for light trucks)."

It is also directed by the EPA's Guidelines for Preparation of Economic Analyses (p. 11-2, available at:
http://vosemite.epa.gov/ee/epa/eed.nsf/pages/Guidelines.htmn:

"An economic analysis of regulatory or policy options should present all identifiable costs and benefits
that are incremental to the regulation or policy under consideration. These should include directly
intended effects and associated costs, as well as ancillary (or co-) benefits and costs."

629


-------
In line with this guidance, the EPA estimates all of the anticipated costs and benefits associated with a
regulatory action, to the extent feasible. We further note that we were unable to monetize other
important benefits, including health benefits of ozone reductions, additional PM2.5 health benefits, and
direct health benefits of reducing S02. If we were able to fully monetize these benefits, the benefits
would exceed the costs by an even greater amount than we currently estimate.

Regarding commenters' assertion that the EPA is double-counting PM2.5 health benefits achieved by
MATS with those achieved by other regulations and NAAQS, the EPA disagrees with these commenters
that the quantified PM2.5 health benefits are double-counted with the health benefits achieved by other
regulations. The EPA's standard practice for its rules is to estimate, to the extent data and time allow, all
benefits of the emissions reductions achieved by a rule beyond control requirements for other rules. If
this rule was duplicative with other rules, then there would be no additional costs or benefits attributable
to this rule.

When the EPA estimates the benefits for rules like MATS, we include other rules such as the CSAPR in
the "baseline." Any emission changes expected as a result of MATS are additional emission reductions
beyond those regulations (e.g., CSAPR) that were considered to be part of the baseline. Therefore, the
benefits from particle reductions are not double-counting - they are real health benefits from emissions
reductions achieved by MATS alone.

Further, the PM2.5 health benefits expected from this rule are not double-counted with benefits estimated
in the NAAQS RIAs. The NAAQS RIAs illustrate the potential costs and benefits of attaining a new air
quality standard nationwide based on an array of emission control strategies for different sources. In
short, NAAQS RIAs hypothesize, but do not predict, the control strategies that states may choose to
enact when implementing a NAAQS. The setting of a NAAQS does not directly result in costs or
benefits, and as such, the NAAQS RIAs are merely illustrative and are not intended to be added to the
costs and benefits of other regulations that result in specific costs of control and emission reductions.
However, some costs and benefits estimated in this RIA account for the same air quality improvements
as estimated in the illustrative PM2.5 NAAQS RIA.

Regarding quantification of health benefits below the PM2.5 NAAQS, the EPA notes that in
implementing these rules, emission controls may lead to reductions in ambient PM2.5 below the PM
NAAQS in some areas. It is important to emphasize that NAAQS are not set at a level of zero risk.
Instead, the NAAQS reflect the level determined by the Administrator to be protective of public health
within an adequate margin of safety, taking into consideration effects on susceptible populations based
on the scientific literature available at the time the standard is set. Although benefits occurring below the
standard may be less certain than those occurring above the standard, the EPA considers them to be
legitimate components of the total benefits estimate.

In response to the comment on climate benefits, we use best available scientific information and
methods in monetizing the climate benefits of this rule and include a careful discussion of the associated
uncertainties and limitations.

5. Health impacts are minimal and are not thoroughly investigated.

Comment 11: Some commenters (17621, 17689, 17775, 18033, 18963, 18023) argue that utility acid
gas emissions (primarily HC1) cause insignificant harm. Commenter 18023 states that the conclusion
that HC1 could exacerbate ecosystem acidification is speculative and unsubstantiated. Commenters
18033 and 18963 point out that the EPA never provided a finding of public health concern to regulate

630


-------
non-Hg HAP, and provides no evidence that "more stringent control of acid gases would benefit
ecosystems other than some vague referencing of the possibility." Commenters 17775 and 18033 argue
that the predominant HAP in the acid gas group, HC1, poses no significant potential for exceeding the
chronic RfC value according to the EPA's own calculations, even though the PM2.5 benefits in the RIA
are solely attributable to the control of HAP acid gases. Commenters 17621 and 18033 argue further that
because HC1 is a very minor contributor to all acidification of water bodies, the EPA's need for
regulating acid gases from EGU's is insignificant. Commenter 17621 points out that because of this,
HC1 emissions have "not been the focus of past U.S. assessments of acidification."

Response to Comment 11: Based on recent peer-reviewed research including Evans et al. (2011), acid
gases can significantly contribute to acidification. The paper presents experimental results that show 1)
that HC1 is highly mobile in the environment, transferring acidity easily through soils and water, 2) that
HC1 can transport longer distances than previously thought (given its presence in remote ecosystems,
and 3) that it can be a larger driver of acidification previously thought. In 2009 the EPA published a
comprehensive risk assessment of acidification effects of nitrogen and sulfur deposition and in 2011
published a Policy Assessment based on the findings in the Risk Assessment (both documents are
available at: http://www.epa.gov/ttn/naaqs/standards/no2so2sec/index.htmn. Given the extent and
importance of the sensitive ecosystems evaluated in the review of nitrogen and sulfur deposition any
substance that contributes to further acidification must be considered to be affecting the public welfare.

Comment 12: Several commenters (16469, 17621, 17715) take issue with the use of the two primary
health studies used in the benefits analysis (Pope et al., 2002; Laden et al., 2006). Commenter 17715
argues that the studies take a simplistic approach to their calculations (grouping all PM components
together) even though there is evidence that PM components do not all have equal health significance.
Commenter 17621 argues that because the dose-response function for PM2 5 relied on two studies and
not a full review of the published literature, it is flawed and only reflects a subset of the literature.
Commenter 17621 also takes issue with the EPA's choice of dose-response function from the Laden
study; the commenter argues that the EPA should have used only the most recent mortality risks instead
of the risk for a combined time period, because the more recent time period is more relevant to the
present. Commenter 17621 points out that had the EPA used the most recent mortality risk, the benefit
estimates would be much lower. Commenter 17621 disagrees with the EPA's statement that some
studies were excluded from analysis due to having study populations of a "selective nature," because the
commenter argues that this is true of all studies, including the Pope and Laden studies. Commenter
17621 argues that the inclusion of other studies would be appropriate and could change the estimated
benefits. Commenter 17621 argues further that the methodology used in these studies appears flawed,
particularly in the methods used to estimate mortality benefits. They state that this could overestimate
the benefits associated with changes in PM concentrations, and thus these studies should not be used
until the flaws are remedied.

Response to Comment 12: The EPA disagrees that the methodology used to estimate PM25 health
impacts is flawed. The EPA methods for quantifying health benefits of emission reductions are based on
the best available peer-reviewed science and methods that have withstood scrutiny from the EPA's
independent SAB, the National Academy of Sciences, and continuous interagency review. We note that
the evidence on differential toxicity of PM25 components and mixtures is currently inconclusive. We
therefore follow the advice of the EPA's Clean Air Science Advisory Committee (Hammitt et al. 2010,
available at:

http://yosemite.epa.gov/sab/sabproduct.nsf/fedrgstr_activites/2nd%20Prospective%20812%20StudylOp
enDocument&TableRow=2.3#2.), which concluded that "Although the possibility of differential toxicity
among PM25 components could be an important issue, the Council concludes that the state of the

631


-------
knowledge does not permit a useful sensitivity analysis at this time" (p. 6). In response to commenter
17621, we note that we use concentration-response factors from the broadest time periods available to
take advantage of the available data most comprehensively. The choice of relative risk estimates from
Pope et al. (2002) and Laden et al. (2006) is supported by the EPA Advisory Council on Clean Air
Compliance Analysis (Hammitt et al. 2010, available at:

http://vosemite.epa.gov/sab/sabproduct.nsf/9288428b8eeea4c885257242006935a3/59e06b6c5ca665978
52575e7006c5d09!QpenDocument&TableRow=2.3#2.):

"Overall, the HES finds the EPA analyses, data choices, and methodologies to be sound.
The EPA bases its estimates of the mortality benefits of reducing fine particulate matter
(PM2.5) on data analyzed from two large, long-running landmark studies on the health
effects of air pollution, the Harvard Six Cities Study and the American Cancer Society
(ACS) Cancer Prevention Study (CPS). The HES finds the selection of these cohort
studies as the underlying basis for PM mortality benefit estimates to be a good choice" (p.

1).

We further note that we also estimate mortality using functions derived by 12 experts in an EPA-
sponsored expert elicitation (Roman et al. 2008). The Pope et al. (2002) and Laden et al. (2006) studies
were found to be near the 25th and 75th %iles of the mortality effect estimates garnered from the expert
elicitation. Our use of the expert elicitation functions provides one estimate of the range of possible
impacts.

Comment 13: Commenters 17707 and 17824 suggest that there is little evidence to support a link
between air quality and asthma. Commenters cite the increased asthma rate from 3.1% of the population
to 8.2% of the population between 1980-2009, despite the decrease in S02 and NOx rates by 70%.
Commenter 17824 asserts that such evidence raises doubt as to the link between air quality and asthma.

Response to Comment 13: The commenters provide no references to support this argument. The EPA
methods for quantifying health benefits of emission reductions are based on the best available peer-
reviewed science and methods that have withstood scrutiny from the EPA's independent SAB, the
National Academy of Sciences, and continuous interagency review. Note that the EPA estimates the
reduction in asthma attacks, not the onset of asthma, for the calculation of health benefits.

Comment 14: Some commenters (17709, 17727, 17731, 17755, 17805, 18018, 18477) question the
EPA's assessment of health benefits resulting from the reduction in emissions of HAP and substances
other than HAP, such as fine PM. Commenter 18477 points out that in the Utility RTC, the EPA
estimated that nickel emissions from oil-fired utilities would result in additional 0.2 cancer cases per
year. Commenter 18477 also states that "EPA acknowledged in the Utility RTC that there was
significant uncertainty regarding the risks from oil-fired utilities" and that even their conservative
calculations of risk show very low risk of cancers. Commenter 18477 also argues that the EPA has not
investigated the effects of nickel and HAP thoroughly enough to determine health risks, and the
commenter suggests that the EPA should re-evaluate the health risks. This commenter suggests that the
EPA must specifically reconsider the nickel speciation data used to calculate the nickel health risks in
the Utility RTC, and incorporate more data provided by the industry to improve the calculations. The
commenter also conducted their own risk analysis for nickel emissions using an assumption of 5% of
nickel emissions as carcinogenic, and calculated risk below the threshold for delisting a source from
regulation under section 112. Several commenters (17731, 17755, 18018) suggest there is a lack of
substantive HAP health risks linked to current EGU emissions outside of Hg-related benefits, and
commenter 17805 adds that the mechanism of human exposure and risk are poorly understood.

632


-------
Commenter 17731 states that because of the lack of HAP risks, the EPA was unable to quantify all of
the health and environmental benefits of the proposed rule. Commenters 17727 and 17709 point out air
quality modeling by the Midwest Ozone Group showing reductions to comply with the Clean Air
Interstate Rule will allow nearly all areas of the U.S. to meet fine particulate standards, meaning that the
assessment of the proposed rule includes benefits that will already be achieved by other rules. The
commenter requests that the EPA reassess the benefits, so that those living on a fixed income will not be
unnecessarily burdened.

Response to Comment 14: The EPA's assessment of inhalation risks due to non-Hg HAP, by itself, is
sufficient to support the determination that it is appropriate and necessary to regulate EGUs under
section 112 of the CAA (see preamble for further details). The EPA disagrees with the commenters'
assertions that nickel emissions can be assumed to be only 5% as carcinogenic as nickel subsulfide (see
preamble for further details). The EPA disagrees with the commenters' assertion that the EPA's inability
to quantify all of the health and environmental benefits of the proposed rule is due to a lack of associated
HAP risks in the first place; rather, this is due to the lack of scientifically-accepted methodologies for
estimating HAP-related benefits.

6. Health impacts are significant.

Comment 15: Numerous commenters (16404, 17254, 17408, 17409, 17766, 17811, 17852, 17871,
18432, 18435, 18436, 18487, 18501, 19536/19537/19538, 18932) explain that the elderly, young, poor
and minority groups as well as those in the southeast face increased risk of health effects from breathing
HAP. Some commenters (18435, 18436, 19536, 19537, 19538) discuss the vulnerability of children to
the adverse health effects of air pollution, even in the prenatal stages. The commenters further state that
people with chronic diseases are also exceptionally susceptible. Commenter 17811 states that HAP
cause damage to eyes, skin, breathing passages, kidneys, nervous system, particularly to sensitive
groups. In particular, commenter 17811 discusses the serious harm poor air quality causes to children,
such as their lung development and adverse birth outcomes. Commenter 17811 cites studies that say
harmful exposures among minority populations may be more than twice as great as exposures to the
average U.S. population. Commenter 17766 describes a coal-fired power plant in Milwaukee, Wisconsin
that emits 5,000 tons of CO2, 1,500 tons of NOx, and almost 350,000 tons of particulates into the air
annually; a third of asthmatics in Wisconsin live within a few miles of the plant, and most of those who
do are minorities. Several commenters (17766, 19536, 19537, 19538) also point out that power plants
tend to be near low income people who lack insurance and do not have paid sick leave, and thus air
pollution will cause greater inconveniences for them. Commenter 17409 refers to studies that associate
violence, mental retardation, and schizophrenia with higher levels of metals in the blood. Commenter
17254 cites several studies showing the susceptibility of sensitive populations to poor air quality,
including one study that revealed a "clear association between respiratory emergency department visits
in Atlanta and sulfate rich fine PM, the kind of fine particles formed in the atmosphere as a result of
gases emitted by coal fired power plants." Commenter 17254 also cites a study showing that "children
with autism were more vulnerable to environmental pollutants because they have lower levels...of the
body's natural defense for excreting environmental pollutants." Commenter 18932 states that the
southeast has one of the highest concentrations of coal-fired power plants in the nation, putting an undue
health burden on the population.

Response to Comment 15: The EPA agrees that exposure to fine particulates and toxic air pollutants is
associated with many adverse health effects and reducing exposure to these pollutants is associated with
substantial public health benefits.

633


-------
Comment 16: Many commenters (16404, 16826, 17157, 17283, 17409, 17620, 17676, 17811, 17843,
17875, 17916, 18022, 18027, 18029, 18039, 18421, 18425, 18432, 18435, 18436, 18477, 18478, 18487,
18501, 18759, 19145, 18932) describe the Hg and non-Hg HAP that contribute to premature death,
environmental contamination and exposure, and a host of diseases. Commenter 19145 cites the statistic
that at least 1 in 12 women of childbearing age have enough Hg in their bodies to put a baby at risk for
Hg poisoning. Commenter 18759 reports that 25 million Americans have asthma, of which 7.1 million
are children. Commenters 18435 and 18425 state that SO2 and NOx are dangerous pollutants that will be
significantly reduced by this rule. Commenter 18435 argues further that many of the constituents of
PM2.5 are known to cause cardiovascular effects and respiratory harm. Commenter 18435 also presents
the results of their calculation using the CALPUFF atmospheric dispersion model to estimate health
benefits from the proposed rule; their calculations showed that use of the best available control
technology would avert 70 deaths per year in a population of 33 million people. Commenter 18421
points out the toxic effects of lead, particularly to children, and the potential carcinogenicity of organic
HAP like dioxins and furans. Commenter 18039 describes the accumulation of Hg in the environment,
and the resulting exposure this causes to the population.

Commenter 17916 states that the rule will also reduce emissions of harmful criteria pollutants.
Commenter 17843 describes the link between nickel emissions with increased risk in daily mortality.
Commenter 17620 states that the "most recent EPA assessment of cancer risks from ambient HAP
concentrations estimates that the entire US population at the time of the assessment had an increased
cancer risk of greater than 10 in 1 million, while 13.8 million people have an increased cancer risk of
greater than 100 in a million, as a result of breathing HAP at 2005 ambient levels over the course of
their lifetime." Commenter 18932 cites a study that concluded that metals and other toxic substances
known to be emitted by coal-fired power plants created elevated risk levels for cancer and non-
cancerous health effects and are known to seriously injure human health. Many of the toxic metals from
coal combustion are emitted as fine particulates, which bypass the body's defenses and lodge in the
lungs leading to short and long-term health problems. Multiple commenters (17157, 17409, 17620,
17826, 18029, 18487, 18759) state that the 400 coal-fired power plants across the country release over
386,000 tons of HAP annually, and cleaning up these power plants can save over 17,000 lives annually.
Commenter 17409 cites a study in Pennsylvania that estimates 1359 premature deaths are attributed to
toxic emissions from power plants in 2010. This commenter (17409) also cites a Clean Air Task Force
study that estimates the health impacts of the plant BL England at 32 heart attacks, 300 asthma attacks,
and 19 deaths. Commenter 18487 states that due to the high toxicity of dioxins, these should be
regulated in the final rule. Commenters 16404 and 18932 cite estimates of over 13,000 deaths, nearly
10,000 hospitalizations and more than 20,000 heart attacks per year nationwide at an economic cost of
$100 billion. Some commenters (17283, 18932) do not fully agree with the decision to use PM2.5 as a
surrogate for all non-Hg metal HAP, but they support the EPA's finding that toxic components of fine
particulate pollution from coal-fired power plants must be regulated under stringent MACT standards.
Commenter 18932 discusses a study in Alabama that concluded that the levels of air toxics in the air had
"elevated risk levels for cancer and non-cancerous health effects" and are "emitted in harmful quantities
by coal-fired power plants in the region." Commenter 18932 also details the amount of each of the
following pollutants as well and the health issues associated with them: arsenic, antimony, beryllium,
cadmium, chromium hexavalent compounds, cobalt, manganese, nickel, selenium sulfide, hydrogen
cyanide, hydrogen chloride, hydrogen fluoride.

Several commenters (18421, 17921, 17811, 18436) argue that HAP cause acidification and degradation
to the environment. Commenters point out that toxic metals contaminate and bioaccumulate in
waterways and animal life, causing further exposures to local communities and harming recreational
activities. Commenter 17921 points out that it is difficult to determine health effects of acid emissions,

634


-------
though occupational exposures to HC1 and HF have been shown to have health effects, and prospective
studies show deleterious lung effects in children. Commenter 18421 states that coal-fired plants are
responsible for approximately 76% of all acid gas emissions, which they argue can cause problems in
the upper respiratory tract, especially harmful to children. Commenter 18421 also states that acid gas
emissions contribute to acidification of ecosystems, and this causes harm to human health and the
environment.

Several commenters (19536, 19537, 19538) explain that meeting the limits for toxic air emissions set by
the proposed rule provides reductions in secondary PM2.5, especially in SO2 and NOx- In addition, the
commenter points out that fuel switching and retirements are also expected to reduce NOx emission and
nitrate particles.

Response to Comment 16: The EPA agrees that the proposed rule will lead to reductions of criteria and
HAP responsible for significant adverse health effects and that such reductions will produce substantial
public health benefits.

The EPA agrees that Hg exposure in wildlife is responsible for various adverse health effects in many
species across the U.S. and recognizes that research is ongoing in this area. As discussed in the
Appropriate and Necessary finding, the EPA agrees that there are environmental risks from exposures of
ecosystems through Hg and non-Hg HAP deposition. The benefits to ecological health remain
unquantified in the assessments for this rule due to data and methodological limitations. The EPA cited
relevant articles from the special edition of Ecotoxicology mentioned by the commenter in the
ecosystem effects section on Chapter 5 of the RIA for this rule. Ecotoxicology. 17:83-91, 2008.

The EPA agrees that acidification poses a significant risk of adverse effects to fish and wildlife in
aquatic and terrestrial ecosystems. Please refer to EPA's recent Risk and Exposure Assessment for
Review of the Secondary National Ambient Air Quality Standards for Oxides of Nitrogen and Oxides of
Sulfur-Main Content - Final Report available at

http://www.epa.gov/ttn/naaqs/standards/no2so2sec/data/NOxSOxREASep20Q9MainContent.pdf for a
comprehensive report on those effects including increased Hg methylation in acidified systems. Based
on recent peer-reviewed research including Evans et al. (2011), acid gases can significantly contribute to
acidification and the EPA agrees that those acid gases pose a risk for acidification of ecosystems.
However due to data and methodological limitations the EPA was not able to quantify those risks and
benefits.

Regarding health effects of acid emissions, the EPA agrees that the large percentage of acid gas
emissions that can be attributed to EGUs may cause or contribute to chronic respiratory health problems.
They are being subjected to emission limits in today's final rule.

7. The proposed rule will harm public health.

Comment 17: Commenter 17919 suggests that the proposed rule will adversely impact public health by
increasing the cost of medical care, by "suppressing economic growth and the improved health it
brings," and by inefficiently using resources on expensive rulemakings instead of other public health
measures. The commenter points out that the health sector is the second most energy intensive
commercial sector, and increases in energy costs would translate to rapid increases in health care costs.

Response to Comment 17: The commenter's assertion relies on the theory that the cost of the rule will
result in lost income or employment that will, in turn, result in negative health effects that offset the

635


-------
positive health effects of the rule. (This is referred to as a "health-health tradeoff") The EPA disagrees
with this point and notes that there are a number of conceptual and empirical problems with any attempt
to quantify the health-health tradeoffs of regulatory action to control air pollution. These analyses rely
on questionable applications of cross-sectional data and ignore key factors that may influence changes in
population health risks. Additionally, marginal decreases in household income caused by the pass
through costs of the regulation are unlikely to cause large changes in any single aspect of household
spending, such as health care. These analyses also fail to consider that household income may increase if
individuals are able to work (or work more) as a result of improved health, offsetting some or all of the
pass through costs of the rule. For these reasons, the EPA's science and economic peer review panels
have consistently advised against attempting to quantify any health-health tradeoffs of regulation.

8.	Support for the proposed rule.

Comment 18: Multiple commenters (12267, 17381, 17852, 17871, 17880, 17882, 17903, 17916, 18022,
18432, 18435, 18438, 18478, 18501, 18961) support the proposed rule and agree with the regulations
designed to address the source of pollution as strictly as necessary to protect human health. Commenters
17882 and 18501 further add that coal-fired power plants are responsible for 99% of Hg emissions from
the power sector in the U.S., justifying the rule. Commenter 17903 points out that some air toxics exist
at high levels near coal-fired facilities, such as aldehydes and PAHs, that are not regulated by any
ambient monitoring requirements. Commenter 17916 points out that much of the Hg deposited in
Ontario originates in U.S. coal-fired EGUs, that has many potential adverse health effects, thus they
strongly support the rule. Commenters 18432 and 18435 further urge the EPA not to weaken the
proposed rule.

Response to Comment 18: The EPA acknowledges generally supportive comments (including
commenters 12267, 15002, 17381, 17648, 17852, 17871, 17880, 17882, 17903, 17916, 17921, 18022,
18432, 18435, 18438, 18478, 18501, 18541, 18961, 19536, 19537, 19538, 18932) on the quantification
of PM2.5 health co-benefits. The EPA agrees with these commenters that the large health co-benefits of
this rule resulting from PM2.5 reductions far outweigh the costs and may underestimate the true benefits,
as some health impacts (e.g., ozone health benefits, enhanced ecosystem services, increased fish
consumption by women) were not able to be quantified.

9.	Miscellaneous comments.

Comment 19: Commenter 16630 asks how averaging in combination with the credits affect the
environment.

Response to Comment 19: In the proposed rule, the EPA planned to allow averaging of existing
sources in the same subcategory at a common plant site for a given HAP. New and existing sources
could not average and oil and coal could not average. This will not change for the final rule. The EPA
has designed a rule that is intended to offer flexibility (including the averaging provisions), to the extent
possible, while ensuring public health is protected in accordance with requirements outlined in the CAA.

Comment 20: Commenter 17734 submits information on technology developed by the commenter's
company that could be used to remove HAP from EGUs. The technology is a "non-carbon Hg sorbent
that effectively captures Hg from coal-fired plants" from Novinda.

Response to Comment 20: The EPA thanks the commenter for this information but believes this
comment is out of the scope of this rule.

636


-------
Comment 21: Commenter 17736 disagrees with the EPA's claim that "it is reasonable to only consider
emissions reductions achieved from requirements directly imposed on EGUs because EPA cannot
predict with any certainty how EGUs would satisfy other required reductions." The commenter argues
that the EPA can use the EGU's Title V permit to identify all CAA requirements and make regulations
accordingly.

Response to Comment 21: Commenter appears to take issue with the EPA's approach to evaluating
whether it is "necessary" to regulate EGUs. See the preamble to the proposed and final rule for the
EPA's interpretation of the term necessary and determinations that it remains necessary to regulate HAP
emissions from EGUs. As indicated therein, we maintain that the 2000 finding was reasonable at the
time it was made based on the available information and that our new analyses of wherein we
considered whether HAP emissions remaining after imposition are reasonably anticipated to pose a
hazard to public health and the environment far exceeds what is contemplated in CAA section
112(n)(l)(A).

Comment 22: Commenter 17811 argues that the proposed rule is insufficient to reduce levels of HAP to
safe concentrations, based on modeling and monitoring data in Alabama.

Response to Comment 22: The EPA disagrees that today's final rule, which is technology-based, must
reduce levels of HAP from EGUs to safe concentrations. It is the requirement of the residual risk
rulemaking, which must occur within 8 years of promulgation of the technology-based standards, in
which EPA evaluates whether additional HAP emissions control is necessary to protect public health
with an ample margin of safety. We have based the final rule on the performance of the best performing
sources in accordance with the statute.

Comment 23: Commenter 18502 argues that Puerto Rico currently is in compliance with all ambient air
quality standards and thus further reductions in HAP emissions from the proposed rule will have no
benefits to air quality on the island.

Response to Comment 23: Compliance with the NAAQS is not relevant to whether there would be
benefits associated with this rule. The benefits are related to the emission reductions associated with
applying controls. Both PM and ozone as well as many HAP have no threshold below which there are
no health effects. Therefore, reducing emissions will lead to health benefits, even though we don't have
the data to quantify these benefits at this time.

Comment 24: Commenter 17848 states that the numbers regarding monetized benefits in the proposed
rule do not match the RIA. The rule states that total Hg-related benefits were calculated to be $450,000
to $890,000 at a 7% discount rate while the RIA states that Hg-related benefits were calculated to be
$5,000 to $9,000 at a 7% discount rate. The commenter requests that the EPA review the information
and revise accordingly, and also suggests that the EPA use a single base year (2006$ or 2007$) when
tabulating benefits.

Response to Comment 24: Any discrepancies in the proposal will be corrected in the final RIA. All
costs and benefits are presented in 2007$ in the final RIA.

637


-------
6L - Impacts/Costs: Mercury Benefits

Commenters: 12798, 15002, 15160, 16122, 16682, 17254, 17405, 17408, 17409, 17620, 17621, 17676,
17679, 17681, 17682, 17683, 17716, 17731, 17732, 17751, 17754, 17761, 17766, 17789, 17811, 17843,
17844, 17854, 17875, 17882, 17904, 17922, 17926, 18014, 18020, 18033, 18043, 18248, 18421, 18425,
18432, 18435, 18436, 18443, 18484, 18487, 18498, 18500, 18541, 19210, 19214, 19506, 6640, 18932,
18023

1. General impacts.

Comment 1: Commenter 17807 states that the EPA should incorporate the latest Hg toxicological data,
reevaluate its conclusions, and determine whether the proposed rule is appropriate and necessary.

Response to Comment 1: The EPA disagrees that the data and methods used to determine the risks and
benefits for the proposed rule are inadequate. The SAB in its review of the EPA's Risk Assessment and
supporting TSD finds that "the risk assessment provides an objective, reasonable, and credible
determination of the potential for a public health hazard from mercury emitted from U.S. EGUs." The
SAB approved of the overall design and general approach and considered the spatial resolution of the
modeling of Hg deposition to watersheds to be appropriate for the analysis. There was agreement that
the approach used to identify watersheds to include in the assessment was reasonable. This approach
was based upon the availability of fish tissue methylmercury data and census data on target populations
with potential subsistence fishers. The SAB agreed that the EPA's calculation of a hazard quotient for
each watershed included in the assessment is appropriate as a principal means of expressing risk.

The EPA Science Advisory Board Report available at:

http://vosemite.epa.gov/sab/sabproduct.nsf/ea5d9a9b55cc319285256cbd005a472e/aaf67ae4ddl9940985
2578cb006bcb04!QpenDocument

Comment 2: Commenter 18023 states the if the EPA had reported IQ loss estimates to only whole
numbers or one significant figure, the differences between the scenarios in Table 5-6 would be zero
indicating no benefit at all. According to the commenter, the EPA compounds this mistake by estimating
a cost associated with accumulated IQ loss after recognizing that these benefits would be lower if lags
were properly considered.

Response to Comment 2: The EPA disagrees with the commenter's statement that the benefits
calculated would be zero. The benefits calculated are averaged across the population and hence the small
increments yield the benefits reported. In addition, the EPA recognizes that the IQ benefits presented are
an underestimate of the benefits of reducing Hg emissions. According to the SAB's review of the
Mercury Risk TSD for this rule, "The loss of IQ points is likely to underestimate the impact of reducing
methyl mercury in water bodies. The reason is that IQ score has not been the most sensitive indicator of
methylmercury's neurotoxicity in the populations studied. As noted in the Mercury Risk TSD, in the
Faroe Island study the most sensitive indicators were in the domains of language (Boston Naming),
attention (continuous performance) and memory (California Verbal Learning Test), neuropsychological
tests that are not subtests of IQ tests and are not highly correlated with global IQ. In the Seychelles
study, the Psychomotor Development Index has been most sensitive measure and, while this is a
component of the Bailey Scales of Infant Development, it is not highly correlated with cognitive
measures."

638


-------
The EPA acknowledges that MMAPS does not account for a time lag in ecosystem response to
reductions in Hg emissions. Ecosystems are highly variable in their response to reductions in Hg
emissions. Due to limitations in data and methodology, EPA was not able to quantify the effect of lag
times on benefits.

Comment 3: Commenter 17621 states that with respect to the "hypothetical full scale IQ" this relatively
small incremental change in IQ (0.18 on a 100-point IQ scale) associated with a 1 ppm Hg increase in
hair cannot itself be measured for an individual, but must be estimated for the total population (through a
series of analytical and exposure assumptions) to derive estimates at the national level (e.g., 510.8 IQ
points saved in RIA, Table 5-7). The individual effects estimates for the "average" IQ loss per exposed
child were defined out to the fourth or fifth decimal place (see RIA, Tables 5-6 and 5-7) to indicate the
potential (and relatively) small effects across the different exposure scenarios.

Response to Comment 3: Although the EPA disagrees that the IQ results are too small to be important,
the EPA acknowledges that IQ is not the most sensitive neurodevelopmental endpoint affected by
methylmercury exposure. The EPA analysis of potential IQ loss from methylmercury exposure is for
population effects, as is done for any quantitative estimate of risk. For precision, it is appropriate to use
a large number of significant figures in calculation, if this is supported by the data inputs. Upon
completion of calculations, the estimate is rounded to the number of significant figures reflective of the
least precise term. In the case of IQ, based on the effect estimates from the underlying epidemiological
studies and the exposure estimates, the level of precision is to 2 significant digits to the right of the
decimal place.

The EPA independent SAB recommended that the IQ analyses be retained but de-emphasized in the
documentation underlying the final regulation (U.S. EPA-SAB, 2011). SAB concluded, "The Panel does
not consider it appropriate for EPA to use IQ loss in the risk assessment and recommended that this
aspect of the analysis be de-emphasized, moving it to an appendix where IQ loss is discussed along with
other possible endpoints not included in the primary assessment. Although the Panel agreed that the
concentration-response function for IQ loss used in the risk assessment is appropriate, and no better
alternatives are available, IQ loss is not a sensitive response to methylmercury and its use likely
underestimates the impact of reducing methylmercury in water bodies." (U.S. EPA-SAB, 2011) The
EPA is following the SAB recommendation by deemphasizing the IQ analysis and placing that analysis
in an appendix to the revised TSD.

Comment 4: Many commenters (15002, 15160, 17408, 18425, 18421, 18432, 19210, 12798) support
this rulemaking because it will reduce human health risks associated with exposure to Hg emissions
from EGUs. Several commenters (19210, 15160, 18421) note that HAP, such as Hg, are linked to many
health problems, including cancer, heart disease, neurological damage, birth defects, asthma, and
premature deaths. Commenterl2798 states that the health of Americans and the economy will be greatly
aided by these new regulations. The commenter quotes a Harvard study that found Hg emissions from
coal-fired power plants may cost the country nearly $30 billion per year in health, environmental and
economic impacts and suggested a cost of another $100 billion per year from particulate emissions and
$200 billion from climate change emissions. The commenter considers these costs outweigh the
potentially higher utility bills that could result from the proposed rule, and states that the utility sector
has had adequate time to prepare. Commenter 18421 notes that data from several studies have shown
links between methylmercury exposure, adult leukemia, and increased mortality rates (Salonen, J.T., K.
Seppanen, T.A. Lakka, R. Salonen and G. A. Kaplan, Mercury accumulation and accelerated
progression of carotid atherosclerosis: A population based prospective 4-year follow-up study in men in
Eastern Finland, Atherosclerosis. 148, 265-273 (2000) and Yorifuji T, Tsuda T, Kawakami N, Age

639


-------
standardized cancer mortality ratios in areas heavily exposed to methyl mercury, 88Int. Arch. Occup.
Environ. Health. 679, 679-88 (2007).

Response to Comment 4: The EPA agrees that exposure to fine particulates and toxic air pollutants is
associated with many adverse health effects and reducing exposure to these pollutants is associated with
substantial public health benefits. The EPA also agrees that the benefits of the proposed rule outweigh
the potential costs and that the proposed implementation schedule is reasonable.

Comment 5: Commenter 15002 expresses concern that even low levels of Hg exposure may be harmful
because none of the studies of Hg toxicity have shown a threshold effect.

Response to Comment 5: The EPA agrees that there may be no threshold below which PM, Hg and
other HAP have no effect and, in fact, the EPA uses a linear relationship in the concentration-response
functions for those pollutants.

Comment 6: Commenter 19506 questions whether the benefits associated with the rule will actually be
achieved. This commenter notes that the Hg emissions within Indiana have decreased by approximately
20% over the past 14 years, but concentrations of Hg from wet deposition sampling have only decreased
by 7% with no apparent change in Hg concentrations within fish tissue in Indiana over the past 22 years.

Response to Comment 6: The EPA disputes the commenter's belief that this rule will not reduce Hg
levels in fish. The data used in support of this RIA do not reflect the commenter's assertion. The EPA
notes that in some cases, Hg levels in fish can decrease quickly following reductions in Hg deposition.
However, the time lag between reduced Hg deposition and reduced Hg levels in fish can vary greatly
and is not accounted for in the RIA benefits analysis.

Comment 7: Commenter 18500 states that the EPA describes the Hg problems without providing
evidence that actual harm in the U.S. can be attributed to EGU Hg emissions, or even to all Hg
deposition. According to the commenter, the EPA fails to demonstrate that meaningful benefits will be
obtained from reducing Hg deposition in the U.S. On page 4.9 of the March 2011 RIA for the Toxics
rule, the EPA states, "Model results for the continental United States indicate that total mercury
deposition (wet and dry forms) reductions from this sector [EGUs] would be 24,000 [j,g/m2(1.0% of total
mercury deposition from all sources.

Response to Comment 7: The EPA disagrees with the commenter's assertion that meaningful benefits
would not accrue to the public due to reductions in Hg from U.S. EGUs. Chapter 5 of the RIA presents a
detailed analysis of the benefit to IQ in children. The SAB has supported the model used in the RIA
analysis and states, "The support for the model of the relationship between IQ and methylmercury
exposure comes from Axelrad and Bellinger (2007) and from a whitepaper produced by Bellinger
(2005)." (U.S. EPA-SAB, 2011) The analysis in the RIA is not intended as the basis of the rule. It is
intended only to estimate the costs and benefits of the proposed rule and therefore the IQ loss estimates
presented in the RIA do not represent an attempt to afford more stringent than necessary protection in
this rule. Furthermore, the EPA does not believe that the benefits of this rule are insignificant. The
benefits of reduction of Hg exposure are underestimated on several counts 1) IQ is not the most sensitive
indicator of neurological effects, 2) many health effects are unquantified, 3) benefits of reduction of
other HAP are unquantified and 4) effects on ecosystems and wildlife are likewise unquantified. In
addition, the co-benefits of reducing PM exposure are quite substantial and outweigh the costs of the
rule.

640


-------
In addition, the EPA recognizes that the IQ benefits presented are an underestimate of the benefits of
reducing Hg emissions. According to the SAB's review of the TSD for this rule, "The loss of IQ points
is likely to underestimate the impact of reducing methyl mercury in water bodies. The reason is that IQ
score has not been the most sensitive indicator of methylmercury's neurotoxicity in the populations
studied. As noted in the TSD, in the Faroe Island study the most sensitive indicators were in the domains
of language (Boston Naming), attention (continuous performance) and memory (California Verbal
Learning Test), neuropsychological tests that are not subtests of IQ tests and are not highly correlated
with global IQ. In the Seychelles study, the Psychomotor Development Index has been most sensitive
measure and, while this is a component of the Bailey Scales of Infant Development, it is not highly
correlated with cognitive measures."

Comment 8: Commenter 18023 states that the EPA's analysis lacked transparency and therefore
prevented meaningful review. One example, according the commenter, was the point the EPA made in a
footnote on Page 5-78 of the RIA that monetized benefits of the rule could be significantly lower if lags
in response to decreased Hg deposition were taken into account. The commenter states that lags are
known to occur in many if not most aquatic ecosystems and that "a portion of the deposition is unlikely
to reach the water at all."

Response to Comment 8: The EPA acknowledges that MMAPS does not account for a time lag in
ecosystem response to reductions in Hg emissions. Ecosystems are highly variable in their response to
reductions in Hg emissions. Due to limitations in data and methodology, the EPA was not able to
quantify the effect of lag times on benefits.

2. Impacts on pregnant women and children.

Comment 9: Many commenters (15002, 15160, 16682, 6640, 17676, 17408, 17766, 17844, 17854,
17875, 17922, 18421, 18432, 18435, 18436, 18932) express concern about the Hg levels found in
children and women of childbearing age. Several commenters (15002, 18932, 17875) express concern
that a large number of women of childbearing age are exposed to Hg at levels that lead to cord blood Hg
levels that exceed the EPA reference dose. Commenters 15160 and 17408 identify potential health
impacts of Hg exposure in children and developing fetuses, including speech, motor control, reading and
writing as well as asthma, neurological damage, cancer, birth defects and other chronic health disorders.
Commenter 15160 quotes data from the NC Department of Health and Human Services that estimate at
least 11,811 babies are born annually with blood Hg levels that put them at risk for lifelong learning
disabilities, fine motor and attention deficits and lowered IQ. Commenters 15160 and 17875 note that as
many as one in six women of childbearing age have enough Hg in their blood to present a serious risk to
a fetus during pregnancy.

Comment 10: Commenter 16640 explains that Hg accumulates in the environment and causes
exposures long after being released from a power plant and bioaccumulates in humans along with
arsenic, chromium and lead. The commenter quotes the American Academy of Pediatrics Policy
Statement on Mercury which calls for, "..efforts should be made to reduce exposure to the extent
possible to pregnant women and children as well as the general population." The commenter urges the
EPA to set the strongest possible standard for Hg and other air toxics.

Response to Comments 9 -10: The EPA agrees that Hg levels in women of childbearing age are of
concern and that in utero exposure to levels above the reference dose may lead to adverse health impacts
in children. The EPA further agrees that Hg and certain other HAP bioaccumulate and persist in the
environment.

641


-------
Comment 11: Several commenters quote data from recently published studies on the impacts of Hg
exposure. These include:

•	Commenter 17676 quotes data published in 2000 by the National Academy of Science and the
National Research Council showing that over 60,000 children are born each year at risk for
adverse neurological effects due to in utero exposure to methylmercury (see National Academy
of Science and Nation Research Council, Toxicological Effects of Methylmercury, 2000,
available on the Web at: http://www.nap.edu/openbook.php7record id=9899&page=327. 327).

•	Commenter 18421 quotes a 2006 study by Dr. Kathryn Mahaffey estimating that approximately
410,000 infants are born in the U.S. each year to mothers with blood Hg concentrations in excess
of the EPA's reference dose.

•	Commenter 18421 quotes a recent study of women conducted in Durham, North Carolina that
found 30% of the women participating in the study had at least 1 ug/L of Hg in their blood,
approximately 2% had blood Hg levels above 3.5 ug/L (level considered to be of concern during
pregnancy), and 12.5% of women of Asian/Pacific Islander decent had blood Hg levels above
3.5 ug/L (see Miranda et al., Mercury Levels in an Urban Pregnant Population in Durham
County, 8 North Carolina. Int. J. Environ. Res. Public Health 698, 698-712 (2011).

•	Commenter 17408 quotes research conducted at the Children's Environmental Health Sciences
Center at the University of Wisconsin that demonstrates developmental exposures to Hg are
sufficient to cause alternations to nerve function causing permanent damage that has been
implicated in development of neurodegenerative diseases, such as Alzheimer's and Parkinsons.
This commenter also notes that recent research has shown that the toxic effects of Hg exposure
are passed down from one generation to another resulting in developmental and behavioral issues
in the children and grandchildren of individuals exposed to low levels of Hg.

•	Commenter 18421 quotes two studies conducted in Korea. The first study identified a link
between adult leukemia and exposure to high levels of methylmercury (see Yorifuji T, Tsuda T,
Kawakami N, Age standardized cancer mortality ratios in areas heavily exposed to methyl
mercury, 88Int. Arch. Occup. Environ. Health. 679, 679-88 (2007). The second study evaluated
274 Korean children found an association between Hg concentrations in urine and increased
cholesterol, which is a risk factor for various forms of cardiovascular impacts (see Bose-O'Reilly
et al, Mercury Exposure and Children's Health, Curr Probl Pediatr Adolesc Health Care. 2010
September; 40(8): 186-215).

•	Commenter 18432 quotes a recent study conducted in the City of Chester and Borough of
Eddystone, Pennsylvania located in close proximity to coal- and oil-fired EGUs. This study
shows that asthma rates among children in these communities exceed 36 %.

Other commenters (18421, 18541, 17408-14) identify instances of methylmercury poisoning, such as the
outbreaks in Minamata, Japan where the mothers exposed to elevated levels of methylmercury through
consumption of contaminated fish typically did not exhibit any symptoms themselves, but gave birth to
children with severe neurological and birth defects. Commenter 18421 also cites an outbreak of Hg
poisoning in Iraq where consumption of contaminated grains resulted in serious reproductive impacts,
including lower levels of pregnancies among the affected population.

Response to Comment 11: The EPA agrees with the commenters that research is ongoing and that new
findings are being published that shed new light on these ubiquitous and harmful pollutants. The EPA is
aware of the poisoning events detailed in the comments above and included descriptions of these events
in the RIA for this rule.

642


-------
Comment 12: Commenter 17681 questions whether this rulemaking will reduce the health impacts of
Hg exposure on women and children. This commenter argues that this rulemaking may not reduce the
Hg exposure for women of childbearing age that eat canned fish because it may result in manufacturing
companies relocating to countries where there are less stringent Hg emission limits on EGUs.

Response to Comment 12: The National Scale Mercury Risk Assessment shows that changes in Hg
emissions from 2005 to 2016 are in fact likely to result in reductions in U.S. EGU attributable fish tissue
Hg concentrations.

3. Impacts on IQ.

Comment 13: Many commenters (15002, 15160, 17409, 17716, 17766, 18421, 18425, 18435, 19506,
and 18932) note that Hg exposure has been associated with cognitive delays, learning disabilities, and
lower IQ levels. Commenter 15002 notes that the EPA's own analysis has shown that a child born to an
African-American woman in 2016 who consumed fish at the 90th percentile would experience a loss of
approximately 7.7 IQ points in the absence of the proposed rule. Commenters 15160 and 18932 state
that the North Carolina Department of Health and Human Services estimates that at more than 11,000
children per year are born in North Carolina with blood Hg levels that place them at risk for lifelong
learning disabilities, fine motor and attention deficits, and lowered IQ. Commenters 17409 and 18435
identify recent studies such as the 2005 study by Transande that estimated between 300,000 and 600,000
children each year have cord blood Hg levels that are associated with loss of IQ points and estimate that
the lost productivity from the lower IQ levels is almost nine billion dollars.

Commenter 18425 states that severe impacts on cognitive thinking, memory, attention, language, and
fine motor and visual spatial skills have been seen in children exposed to methylmercury in the womb.
This commenter stated that the EPA's data show 10,543 children in Wisconsin were prenatally exposed
to unsafe levels of Hg in 2005, resulting in a 0.10 point loss in IQ per child (a total IQ loss in Wisconsin
of 1,026.2 points). This commenter also notes that the proposed Air Toxics Rule will result in nearly an
8.3% reduction in the average maternal daily Hg ingestion from the 2005 baseline, which would result in
more than 10% reduction in the average IQ loss per child and total IQ loss across Wisconsin due to
reduced Hg exposure from in-state sources.

Response to Comment 13: The EPA agrees that in utero and early childhood exposure to
methylmercury can lead to neurological deficits in children and that the economic consequences of such
deficits can be substantial.

Comment 14: Commenter 15002 believes that the EPA underestimated the impact of Hg on IQ by
restricting the analysis to populations who consume self-caught fresh-water fish and omitting Hg
exposures from other freshwater and saltwater fish. This commenter also stated there is no evidence to
support the hypothesis that some low level of Hg exposure is entirely without effect and that if the effect
of lead on IQ extrapolates to the Hg, then low level Hg exposures may have a greater effect per unit
exposure than higher levels.

Response to Comment 14: The EPA agrees that there may be no threshold below which PM, Hg and
other HAP have no effect and, in fact, the EPA uses a linear relationship in the concentration-response
functions for those pollutants. We acknowledge the commenter's belief that the analysis of Hg impacts
and health benefits may be conservative.

643


-------
Comment 15: Multiple commenters (17621, 17716, 18498, 19506, 17681, 17731, 18033, 18443)
believe this rulemaking will have little impact on IQ. These commenters argue that the EPA RIA shows
only a fraction of an IQ point gain for the most exposed individuals, with the average effected
individuals as prenatal children, 244,000 annually, experiencing only a 2/1000 IQ point gain.

Commenter 18498 questions whether the EPA's IQ impacts are real, while commenters 17716 and
19506 argue that the benefits of the rule are insignificant. Commenterl9506 believes that the benefits to
IQ levels would still be insignificant even if the EPA included the impacts of commercially caught fresh
and saltwater fish and self-caught saltwater fish in their analysis. Commenter 17681 argues that the
aggregated benefit estimate of 0.00209 IQ points lost is below the level that can be measured by an IQ
test.

Commenters 17716 and 17731 state that the EPA's 0.11/ 0.10 average IQ loss per exposed child and
0.176 point for the most at risk group is much lower than the EPA's recent determination that a potential
health risk occurs at 1-2 point IQ loss (The NAAQS for Lead, 73 FR 66964 (Nov. 12, 2008)). The
commenter states that the EPA declined to set a more stringent NAAQS for lead because the estimated
average IQ loss was lower than the 1-2 point range and argues that the proposed Hg limits are likely
more stringent than needed because the current Hg emission levels from EGUs have been shown to
result in a 0.176 point IQ loss for the most at risk children, which is well below the EPA-determined 1-2
point IQ loss level.

Commenter 17621 notes that in monetizing the loss of IQ the EPA relied on the Bureau of Labor
Statistics National Longitudinal Survey of Youth (a national data set used to estimate the relationship
between IQ and lifetime earnings). The commenter states that this survey does not contain a direct
measure of IQ and is instead based on an Armed Forces Qualification Test (AFQT) that has been scaled
to estimate IQ. The commenter states that an early analysis conducted at the request of the military
reported a 0.77-0.80 correlation between AFQT scores and scores on a full-scale IQ test, the Wechsler
Intelligence Scale for Children (Office Secretary of Defense, 1980) and that the EPA should take into
consideration the relative loss of precision in scaling between the AFQT and a full-scale IQ test in light
of the small changes in IQ presented in the RIA IQ loss/reductions analysis.

Response to Comment 15: The EPA disagrees that the IQ impacts are not real and notes that the
average reduction in IQ loss reported in the RIA do not reflect the greater than average impacts that
reduced exposure would have at the tails of the distribution. The EPA uses a linear response model to
predict IQ loss due to methylmercury exposure because there is no literature to date that shows a
threshold below which no effect is observed. The SAB has supported the model used in the RIA analysis
and states that "The support for the model of the relationship between IQ and methylmercury exposure
comes from Axelrad and Bellinger (2007) and from a whitepaper produced by Bellinger (2005). It was
noted that the 1-2 point decrease reflects the mean response, but that a decrease of 1-2 points at the mean
results in a much larger decrease at the tails of the distribution. This can result in a greater impact on
those with IQ's that are much lower or higher than the mean." (SAB Report available at:
http://vosemite.epa.gov/sab/sabproduct.nsf/ea5d9a9b55cc319285256cbd005a472e/aaf67ae4ddl9940985
2578cb006bcb04!QpenDocumenf) The analysis in the RIA is not intended as the basis of the rule. It is
intended only to estimate the costs and benefits of the proposed rule and, therefore, the IQ loss estimates
presented in the RIA do not represent an attempt to afford more stringent than necessary protection in
this rule.

The EPA does not believe that the benefits of this rule are insignificant. The benefits of reduction of Hg
exposure are underestimated on several counts 1) IQ is not the most sensitive indicator of neurological
effects, 2) many health effects are unquantified, 4) benefits of reduction of other HAP are unquantified

644


-------
and 4) effects on ecosystems and wildlife are likewise unquantified. In addition the co-benefits of
reducing PM exposure are quite substantial and outweigh all the benefits estimates for Hg.

The EPA agrees that the differences between the AFQT and full-scale IQ tests are a source of
uncertainty; however, the EPA believes that the effect on the estimates would be very small since the
difference between the two tests is small.

Comment 16: Several commenters (17681, 17769, 17807 and 18034) assert that the 1999 NHANES
data is out of date. These commenters state that more recent data (such as Caldwell, et. al. (2009),
International Journal of Hygiene and Environmental Health, vol. 212, pp. 88-598) show a decline in
NHANES blood Hg levels since 1999 and indicate that blood Hg levels have been below the EPA rfd
since 2001.

Response to Comment 16: The EPA did not apply any data from NHANES survey in the analysis of
Hg effects on IQ in the benefits estimates for the RIA. The estimates were generated using data and
models reviewed by the SAB as part of its review of the TSD. (SAB report available at:
http://vosemite.epa.gov/sab/sabproduct.nsf/ea5d9a9b55cc319285256cbd005a472e/aaf67ae4ddl9940985
2578cb006bcb04!QpenDocumenv)

Comment 17: Commenter 17621 states that with respect to the "hypothetical full scale IQ" this
relatively small incremental change in IQ (0.18 on a 100-point IQ scale) associated with a 1 ppm Hg
increase in hair cannot itself be measured for an individual, but must be estimated for the total
population (through a series of analytical and exposure assumptions) to derive estimates at the national
level (e.g., 510.8 IQ points saved in RIA, Table 5-7). The individual effects estimates for the "average"
IQ loss per exposed child were defined out to the fourth or fifth decimal place (see RIA, Tables 5-6 and
5-7) to indicate the potential (and relatively) small effects across the different exposure scenarios.

Response to Comment 17: Although the EPA disagrees that the IQ results are too small to be
important, the EPA acknowledges that IQ is not the most sensitive neurodevelopmental endpoint
affected by methylmercury exposure. The EPA analysis of potential IQ loss from methylmercury
exposure is for population effects, as is done for any quantitative estimate of risk. For precision, it is
appropriate to use a large number of significant figures in calculation, if this is supported by the data
inputs. Upon completion of calculations, the estimate is rounded to the number of significant figures
reflective of the least precise term. In the case of IQ, based on the effect estimates from the underlying
epidemiological studies and the exposure estimates, the level of precision is to 2 significant digits to the
right of the decimal place.

The EPA's independent SAB recommended that the IQ analyses be retained but de-emphasized in the
documentation underlying the final regulation (U.S. EPA-SAB, 2011). The SAB concluded, "The Panel
does not consider it appropriate for EPA to use IQ loss in the risk assessment and recommended that this
aspect of the analysis be de-emphasized, moving it to an appendix where IQ loss is discussed along with
other possible endpoints not included in the primary assessment. Although the Panel agreed that the
concentration-response function for IQ loss used in the risk assessment is appropriate, and no better
alternatives are available, IQ loss is not a sensitive response to methylmercury and its use likely
underestimates the impact of reducing methylmercury in water bodies." (U.S. EPA-SAB, 2011) The
EPA is following the SAB recommendation by deemphasizing the IQ analysis and placing that analysis
in an appendix to the revised TSD.

645


-------
Comment 18: Commenter 17681 states that the EPA's IQ reduction metric, which it developed to
assess the health impact from Hg emissions, resulted in an "aggregated benefit estimate" of 0.00209 IQ
points lost, well below the level that can even be measured by an IQ test.

Response to Comment 18: The commenter is confusing a measurement based on an IQ test and the
response predicted by the linear model the EPA used to calculate IQ decrements caused by
methylmercury exposure. The EPA uses a linear response model to predict IQ loss due to
methylmercury exposure because there is no literature to date that shows a threshold below which no
effect is observed. The EPA notes that the average reduction in IQ loss reported in the RIA does not
reflect the greater than average impacts that reduced exposure would have at the tails of the distribution.
The SAB has supported the model used in the RIA analysis and states that "The support for the model of
the relationship between IQ and methylmercury exposure comes from Axelrad and Bellinger (2007) and
from a whitepaper produced by Bellinger (2005)." (SAB Report available at:

http://vosemite.epa.gov/sab/sabproduct.nsf7ea5d9a9b55cc319285256cbd005a472e/aaf67ae4ddl9940985
2578cb006bcb04!QpenDocumenf).

4. Impacts on Food.

Comment 19: Many commenters (15002, 15160, 16682, 17405, 17408, 17409, 17254, 17683, 17766,
18043, 18421, 18425, 18435, 18932, 17676, 17679, 17922) support this rulemaking because it will
reduce the levels of methylmercury in the U.S. diet. These commenters consider the consumption of
methymercury in contaminated fish to be a primary health concern and they believe that fish and
shellfish are the main sources of human methymercury exposure. Commenter 18932 states that, as of
2008, all 50 states had issued some type of fish consumption advisory for Hg and 27 states had issued
statewide Hg advisories for all bodies of water in the state. This commenter is also concerned that the
number of fish consumption advisories is increasing, stating that between 2006 and 2008 the number of
Hg advisories rose from 3,080 to 3,361. The commenter also notes that both the EPA and the Food and
Drug Administration (FDA) issued a joint advisory urging women and children not to consume any
shark, swordfish, king mackerel, or tilefish, and to limit white albacore tuna to one meal per week.

Response to Comment 19: The EPA agrees that ingestion of methylmercury in fish is the main route of
exposure in the American diet and that consumption of fish by pregnant women and children above the
levels suggested by the advisories issued by the EPA and FDA can increase the risk of adverse health
effects.

Comment 20: Commenter 15160 reports that Hg from coal-fired power plants in North Carolina has
contaminated food, leading to advisories in North Carolina covering 17 species of ocean fish, walleye,
and bass. Commenter 17254 states that the U.S. Geological Survey has shown that one in four fish
contain Hg levels that exceed recommended EPA criteria and also notes that a recent issue of the
Environmental Health Perspectives recreational anglers have been shown to have higher hair mercury
levels. Commenter 17405 notes that human fish consumption restrictions cover every one of Wisconsin
lakes. Commenter 17408 notes that a study of seafood-eating populations on Faroe Islands in the North
Atlantic has shown that teenagers who were exposed to Hg while still in their mother's womb have
neurological and behavior problems. Commenter 17676 notes that frequent consumption of high-Hg fish
has been associated with a number of harmful effects in adults, including effects on neurologic,
cardiovascular, and immune systems. Commenter 18932 believes that residents in coastal areas may be
exposed to unsafe levels of methylmercury because their diets are especially high in fish and shellfish.
The commenter notes that a study in Alabama found extremely high levels of Hg in hair samples from
coastal residents who consume seafood and fish every week, indicating elevated Hg levels in their

646


-------
bodies overall. In a 1993 study, the North Carolina Department of Health and Human Services
discovered that fishermen and their families were consuming fish from the Waccamaw River that are
under a fish advisory and that blood samples taken from this population had average Hg blood levels of
7.5 ug/L, with approximately 40% of those tested having blood Hg levels greater than the recommended
3.5 ug/L level for women of childbearing age. Commenter 17683 argues that families should be able to
eat safe fish without having to worry about Hg in their bloodstreams and believes that regulation of Hg
emissions from EGUs is overdue. Commenter 16682 states that the proposed rule can achieve reductions
in Hg contamination in fish tissues quickly because levels of Hg in fish tissue quickly drop when the
source is reduced. The commenter believes the proposed EPA standards will protect the public health
and the environment.

Response to Comment 20: The EPA agrees that Hg from coal-fired power plants is a contributor to the
levels of methylmercury in fish across the country and that consumption of contaminated fish can lead to
increased risk of adverse health effects. The EPA agrees that this rule will reduce Hg levels in fish. The
EPA agrees that, in some cases, Hg levels in fish can decrease quickly following reductions in Hg
deposition. However, the time lag between reduced Hg deposition and reduced Hg levels in fish can
vary greatly and is not accounted for in the RIA benefits analysis.

Comment 21: Commenters 15002 and 17679 believe the EPA's analysis underestimates the impact of
Hg emissions because the analysis focuses only on populations who consume self-caught fresh-water
fish. Commenters argue that the EPA should include the contribution to Hg exposures from other
freshwater and saltwater fish, including those most likely to contain large amounts of Hg (such as king
mackerel, swordfish, large tuna, and tilefish). Commenter 17620 states that the EPA's analysis is of
limited usefulness in assessing the health impacts of the proposed rules because it is based on self-
caught freshwater fish rather than on commercially caught freshwater fish and saltwater fish that
constitute the vast majority of the fish consumption in the U.S.

Response to Comment 21: The EPA agrees that the analysis presented in the RIA is an underestimate
of the benefits of reduced Hg exposure in part due to the exclusion of some fish species especially
saltwater fish. The EPA did not include marine fish due to data and methodological limitations.

Comment 22: Some commenters (17702, 17732, 17620, 17751, 18023) believe that the EPA's analysis
is not based on best available science, and that the analysis is flawed and overestimates the impact of Hg
emissions on human health. Commenter 17751 argues that the EPA failed to fully account for the role of
dietary selenium's protective effects against methylmercury toxicity. This commenter states that there is
extensive literature on the beneficial role of dietary selenium and that this literature shows that the
binding affinity of Hg for selenium is up to a million times higher than for sulfur (Hg's second best
binding partner). In support of their argument, this commenter quotes work completed by an EPA-
funded study showing that 97.5% of freshwater fish analyzed for a Western U.S. survey have sufficient
selenium to "potentially protect them and their consumers against Hg toxicity."

Response to Comment 22: The EPA disagrees with the commenters that the best available science was
not used to generate the estimates presented in the RIA. There are uncertainties in the analysis; one of
which is the role of selenium. The EPA was not able to quantify this relationship within the benefits
estimates due to data and methodological limitations. There remains uncertainty with respect to the
nature and magnitude of potential confounding between selenium and methylmercury and the associated
effects on childhood neurodevelopment due to maternal ingestion during pregnancy. Additional research
is needed to provide further clarity on this issue, but recent studies such as those referenced above
reinforce the view that fish consumption during pregnancy should be approached as a case of multiple

647


-------
exposures to nutrients and to methylmercury, with a complex and potentially interactive set of risks and
benefits related to infant development. The EPA SAB Mercury Review Panel, in their peer review of the
EPA's National Scale Mercury Risk Assessment, evaluated the role of selenium in affecting Hg risk,
and there was no consensus on the effects of selenium. The panel agreed that for all fish nutrients, there
is not sufficient information to recommend a quantitative adjustment in health endpoint measures.

Comment 23: Commenters 17751 and 17681 argue that an analysis by Soon (See, Scientific Critique of
EPA's EGU MACT and NSPS Revisions, Willie Soon, PhD, June 2011) identifies a number of material
errors in the EPA's analysis of the health concerns related to Hg emissions from coal-fired EGUs.
Commenter 17751 notes that Soon's analysis and various other peer-reviewed scientific studies indicate
that regulatory management of Hg is likely impossible, because methylmercury bioaccumulation and
methylation are driven by factors others than elemental Hg availability. The commenter believes that
Soon's analysis clearly indicates that Hg emissions and impacts from sources other than those derived
from EGUs greatly exceed the EGU emissions and impact and that even total elimination of all
industrial emissions, inclusive of those from power plants, will not affect trace or even high
methylmercury levels that have been found in fish tissue over century-long time periods. The
commenter concludes that fish consumption advisories as an exposure prevention strategy make more
sense than emissions control strategies.

Response to Comment 23: The EPA disagrees that regulatory management of EGU emissions of Hg is
impossible and is proposing the MATS rule that will lead to reductions of Hg emissions from EGUs.
The National Scale Mercury Risk Assessment shows that changes in Hg emissions from 2005 to 2016
are in fact likely to result in reductions in U.S. EGU attributable fish-tissue Hg concentrations. The EPA
notes that decisions related to Hg emission controls are distinct from decisions about fish consumption
advisories, which are intended to provide information to potential fish consumers. To the extent that
regulations on EGU Hg emissions reduce concentrations of Hg in fish, specific fish consumption
advisory information will reflect those changes in Hg concentrations.

Comment 24: Commenter 17751 disagrees with the EPA's statement that reductions in power plant
emissions will likely result in a reduction in Hg concentrations for fish in the ocean. Commenter 17751
states that much valid, peer-reviewed scientific research has demonstrated that methylmercury in the
world's oceans is not controlled by deposition of atmospheric Hg. As an example, the commenter
discusses studies by Morel, et al. ("Response to Comment on Sources and Variations of Mercury in
Tuna" Kraepiel, A. M. L.; Keller, K.; Chin, H. B.; Malcolm, E. G.; Morel, F. M. M.; Environmental
Science Technology; 2004; 38(14); 4048-4048 (DOI: 10.1021/es0404217)) that show that Hg levels in
tuna caught in the region around Hawaii have not changed over a period during which anthropogenic Hg
inputs in the region have increased. The study's authors suggest that these findings "provides prima
facie evidence that this concentration is not responding to anthropogenic emissions irrespective of the
mechanisms by which mercury is methylated in the oceans and accumulated in tuna." This commenter
further states that the world's oceans contain 40-200 million tons of Hg and that very little of it has been
converted into methylmercury that can be accumulated in fish and that eliminating all of the 105 tons of
Hg emissions released from U.S. anthropogenic sources in 2005 will leave the levels of Hg in the
world's oceans virtually unchanged with a 0.0003 % reduction. Further, the commenter states that the
primary source of exposure to methylmercury for most people living in the U.S. is through consumption
of ocean fish and that exposure to methylmercury from freshwater consumption is statistically
insignificant, as less than 0.05% of total fish and fish products consumed annually in the U.S. are
freshwater fish (Food and Agriculture Organization of the United Nations, Trade in Fish and Fish
Products, Fish Consumption, Fishers and Fleet Information, Tables CM 1.1 and CM 1.2).

648


-------
Response to Comment 24: The EPA disagrees that U.S. Hg emissions do not contribute to the global
pool of Hg or affect Hg concentrations in ocean-going fish. The NAS in its 2009 report Global Sources
of Local Pollution: An Assessment of Long-Range Transport of Key Air Pollutants to and from the
United States http://www.nap.edu/catalog/12743.htmlreport, explains that "Hg is truly a global
pollutant, as it has the potential, once emitted from any source, to be transformed to different chemical
forms, transported through the atmosphere, and deposited long distances from the point of origin.
Reservoirs that accumulate Hg include the atmosphere, the oceans, freshwater systems, soils, biota, and
the cryosphere. Hence intercontinental transport is an important process that clearly affects U.S.
exposures. Continued emissions will increase the amount of Hg in the global pool available for
longrange transport and recycling among these reservoirs in the environment." Thus since the oceans are
considered a sink for Hg pollution it is reasonable to conclude that marine fish would be affected by that
exposure.

Hg accumulation in fish is dependent on many variables including the age and weight of the fish.
Additionally, Hg concentrations are variable across the oceans with methylated Hg accounting " for up
to 29% of the total Hg in subsurface waters (average 260 ±114 fM). We observed lower ambient
methylated Hg concentrations in the euphotic zone and older, deeper water masses, which likely result
from decay of MeHg and Me2Hg when net production is not occurring "(Sunderland,2009).

That being said, the RIA is a national scale assessment which focuses on the exposures to
methylmercury in populations who consume self-caught freshwater fish (recreational fishers and their
families). Although there are other routes of exposure, including self-caught saltwater fish and
commercially purchased fresh and saltwater fish, these exposures are not evaluated because 1) for self-
caught saltwater fish, we are unable to estimate the reduction in fish tissue methylmercury that would be
associated with reductions in Hg deposition from U.S. EGUs, and 2) for commercially-purchased ocean
fish, it is very difficult to determine the source of the methylmercury in those fish, and thus we could not
attribute Hg levels to U.S. EGUs.

Comment 25: Commenter 17751 disagrees with the EPA assessment of a direct one-to-one proportional
relationship between reductions in atmospheric Hg and methylmercury concentrations in fish. The
commenter believes this to be one of several errors that grossly inflate the EPA's estimates of the human
health benefits of the proposed controls on Hg emissions by EGUs and asserts that any health benefits
from the EGU MACT would occur at times far removed from the time at which reductions in emissions
occur.

Response to Comment 25: The EPA disagrees that the health benefits of Hg control are inflated. In fact
the EPA believes that the estimates presented in the RIA are an underestimate because the EPA was not
able to analyze the impacts using the most sensitive endpoints for human health. According to the
SAB's review of the TSD for this rule "The loss of IQ points is likely to underestimate the impact of
reducing methyl mercury in water bodies. The reason is that IQ score has not been the most sensitive
indicator of methylmercury's neurotoxicity in the populations studied. As noted in the TSD, in the Faroe
Island study the most sensitive indicators were in the domains of language (Boston Naming), attention
(continuous performance) and memory (California Verbal Learning Test), neuropsychological tests that
are not subtests of IQ tests and are not highly correlated with global IQ. In the Seychelles study, the
Psychomotor Development Index has been most sensitive measure and, while this is a component of the
Bailey Scales of Infant Development, it is not highly correlated with cognitive measures."

Further, the EPA disagrees that the proportionality assumed in the MMAPS model that relates the
reduction in Hg deposition to reductions in fish tissue concentrations is inappropriate. According to SAB

649


-------
"Since the Mercury Maps approach was developed, several recent publications have supported the
finding of a linear relationship between mercury loading and accumulation in aquatic biota (Orihel et al.,
2007; Orihel et al., 2008; Harris et al., 2007). These studies suggested that that mercury(II) deposited
directly to aquatic ecosystems can become quickly available to biota and accumulated in fish, and
reductions in atmospheric mercury deposition should lead to decreases in methylmercury concentrations
in biota. These results substantiate that the assumption of proportionality between air deposition changes
and fish tissue methylmercury level changes is sufficiently robust for its application in this risk
assessment."

The EPA does agree that there may be a lag time between evidence of health benefits due to the
reduction of Hg emissions and the actual occurrence of the reductions however there is no data available
on how long that lag may be.

Comment 26: Commenter 17751 believes that the EPA should not have relied on Faroe Islands study
because the Faroe Islanders receive Hg exposure by atypical consumption of pilot whale meat
contaminated by PCBs which has little relationship to fish consumption in the U.S. This commenter
asserts that the EPA should have used data from the Seychelles Islands study, because this study is the
most relevant to the U.S., where there was no adverse response observed in women or their children
despite maternal Hg levels 10 times those found in the U.S. Commenter 17751 also notes that (1)
Seychelles islanders consume far more fish than do Americans; (2) the amount of methylmercury in the
U.S. population is 10 to 20 times below that of the Seychelles islanders; and (3) all ocean fish
throughout the world contain about the same amount of methylmercury, so, per fish meal, there is no
difference in methylmercury intake when comparing the seafood diet of Americans to Seychelles
islanders. Commenter 17751 believes that the Seychelles Islands study is the right study to use as a basis
for making a regulatory decisions and assessing the health impacts of Hg.

Response to Comment 26: The comment has several inaccurate statements. As published by Dr Weihe
and colleagues, exposure to methylmercury in the Faroes was largely from consumption of pilot whale
meat; exposure to PCBs was found in the portion of the population who also consume whale blubber.
The lipophilic PCBs are found in the fat compartment of the pilot whales; methylmercury, by contrast, is
bound covalently to protein in the whale meat.

Contemporary publications on data and analyses from the Seychelles Child Development Study of
Methylmercury from Fish Consumption (SCDS) have reported methylmercury-related effects from
testing of older children in their study cohort (e.g., van Wyngaarden et al. 2006; Strain et al., 2008.)

The EPA's RfD for methylmercury is based on multiple endpoints from the three extant large studies of
childhood effects of in utero exposure: Faroes, New Zealand, and an integrative measure including data
from Seychelles. Documentation for the choices underlying calculation of the RfD can be found in the
following sources: U.S. EPA (2001) Water Quality Criterion for the Protection of the Human Health:
Melhy/mercuryEPA-823-J-01 -001, available at

http://water.epa.gov/scitech/swguidance/standards/criteria/aqlife/pollutants/methylmercurv/index.cfm:
U.S.EPA. 2011.Integrated Risk Information System, available at
http://www.epa.gov/iris/subst/0Q73.htm: Rice et al (2003).

5. Impacts on low-income and subsistence populations.

Comment 27: Multiple commenters (15002, 16122, 17409, 17254, 17732, 17766, 17811, 18421, 18435,
18436, 18487, 18932) note that Hg emissions have a disproportionate impact on low-income and

650


-------
subsistence populations, such as Native Americans, Hispanics, and Location subsistence fishers. Several
commenters (17409, 18421, 18932) state that African Americans, Native populations, Latino
communities, Asian Americans (e.g., Vietnamese in the gulf area), and other low income communities
who fish recreationally are more likely to eat the fish they catch. Commenter 17766 states that African
Americans and Hispanics eat more fish that are contaminated with Hg than are their White counterparts
because these groups eat fish to obtain a source of high quality protein and catch the fish themselves to
make up for economic inequities. This commenter quotes 2006 statistics showing that approximately 1.4
million African Americans and 1.3 million Hispanics were avid subsistence anglers. This commenter
further notes that many of these disadvantaged groups fish in urban areas near where they live because
they have limited transportation options and therefore, tend to fish in urban areas where fish are most
Hg-laden. Commenter 18932 quotes a 2005 survey of anglers in Baltimore Harbor, the District of
Columbia, and the Tidewater Region of Virginia where interviewers found that in many instances
anglers stated that they knew of health advisories associated with the fish that they caught, but still ate
the fish and shared them with at-risk members of their families, e.g., women of childbearing age. In the
Tidewater Region of Virginia, the study showed that 91% of those interviewed stated that they ate some
of the fish they caught, 50 % of stated that having a fresh fish dinner was a very important motivation
for fishing, and 19% stated that reducing the cost of food was a very important motivation for fishing.

Response to Comment 27: The EPA agrees that low-income and subsistence fishers are
disproportionately affected by exposure to methylmercury in fish due to their fish consumption patterns.

Comment 28: Commenter 17254 notes that African Americans are disproportionately affected by Hg
emissions because this population have a greater prevalence of kidney disease and are more likely to
reside in closer proximity to industries that emit Hg and other air pollutants. Commenter 18435 provides
maps of the southeastern states showing the proximity between concentrations of low income people,
including both white and African-Americans, and the location of coal-fired power plants and notes that
the close proximity of these plants to waterways near their homes makes it more likely that fish from
those waterways would make part of their diet. Commenter 15002 notes that the EPA's analysis
concluded that a child born to an African-American woman in 2016 who consumed fish at the 90th
percentile would experience a loss of approximately 7.7 IQ points in the absence of the proposed rule.
This commenter stated that this risk represents an unacceptable burden on this population.

Response to Comment 28: The EPA agrees that low-income African Americans are at greater risk of
adverse health outcomes due to their higher consumption rates of fish with high levels of
methylmercury. The EPA agrees that this risk is and unacceptable burden for this population.

Comment 29: Commenter 17732 acknowledges that there are subpopulations of Native Americans
more susceptible to methylmercury exposure because of subsistence diets based on fish and notes that
the 1997 Mercury Study to Congress concludes that exposures among specific subpopulations including
anglers, Asian-Americans, and members of some Native American Tribes may be more than two-times
greater than those experienced by the average U.S. population. However, this commenter believes that
fish consumption is limited and occurs primarily during recreational activities. Commenter 17732 notes
that a 2004 U.S. Fish & Wildlife report concluded that the Navajo "can and should feel comfortable
about consuming fish on a recreational basis..." and further argues that the EPA should not assume that
exposure to Hg and other HAP on Tribal lands are equal in comparison to exposures in the more densely
populated metropolitan and urban areas where population and industrial growth continue to contribute to
hazards to public health and environment. The commenter further recommends the EPA collect more
public health data in areas in close proximity to regional HAP so as to better understand the true public
health and environmental impacts.

651


-------
Response to Comment 29: The EPA agrees that the analyses presented in the RIA focused on Native
American populations with high-end fish consumption patterns specifically the Great Lakes tribes of
Chippewa and Ojibwe whose consumption patterns may constitute a higher risk of adverse health
effects. The people of the Navajo nation were not included in the modeled populations for the risk
assessment or the RIA for this rule. The EPA acknowledges that some Native American populations do
not fit the criteria for subsistence level fishers.

6.	Impacts on tourism and recreational fishing.

Comment 30: Commenters 16122 and 17732 note that Hg contamination of streams, rivers, and lakes
threaten the economy of states and tribes that rely on fishing tourism. Quoting data published by the
U.S. Department of Interior, Fish and Wildlife Service, commenter 16122 notes that the Wisconsin
Department of Natural Resources sells approximately 1.5 million fishing licenses and that the sales of
these licenses, as well as of food, lodging, gasoline, and sporting equipment related to fishing adds
approximately $2.1 billion to the Wisconsin economy and another $5 billion to the states of Illinois,
Indiana, Michigan, Minnesota, and Ohio.

Response to Comment 30: The EPA agrees that Hg contamination of water bodies across the U.S. has
led to fish consumption advisories for those water bodies that may have a negative effect on recreational
fishing. The EPA also agrees that recreational fishing has a large economic impact in many states. The
EPA further agrees that reducing Hg levels in fish should have beneficial effect on recreational fishing.
However, given data methodological limitations, the EPA was not able to estimate those benefits at this
time.

7.	Impacts on wildlife.

Comment 31: Multiple commenters (17679, 18033, 18043, 18248, 18487, 18541, 19214) point out that
Hg emissions have adverse health effects for numerous species of wildlife, including reproductive,
neurological, survival, and behavioral effects.

Response to Comment 31: The EPA agrees that Hg exposure in wildlife is responsible for various
adverse health effects in many species across the U.S. and recognizes that research is ongoing in this
area. The benefits to ecological health remain unquantified in the assessments for this rule due to data
and methodological limitations. Because these benefits are unquantified, the benefits assessment
presented in the RIA for this rule is underestimated and conservative.

8.	Benefits do not justify the rule.

Comment 32: Multiple commenters (17716, 17682, 18484, 18500, 17904, 18020, 17754) argue that the
benefits of the proposed rule do not justify the costs.

Response to Comment 32: The EPA disagrees that the benefits of the MATS rule do not justify the
costs. As the analyses presented in the RIA for the rule show the benefits outweigh the costs by a large
margin. Although the monetized benefits of reducing Hg emissions are not large, those benefits are also
not equally distributed across the population. As the sensitivity analysis shows, some populations
including low-income African Americans and some Native American populations may receive a
disproportionate benefit, and the distributional aspects of the benefits may help to justify the costs of the
rule. Furthermore, the analysis depended on using a less sensitive endpoint (IQ) of neurological impacts
of Hg exposure as noted by the SAB which leads to underestimation of the benefits. Additionally, many

652


-------
other impacts of Hg emissions were not quantified including impacts on ecosystems and wildlife;
especially fish, birds (both fish and insect eating), and mammals. Other HAP controlled by the MATS
rule were likewise not quantified due to data, resource and methodological limitations. Even if we were
able to fully monetize the public health benefits of reducing exposure to Hg and other HAP, it is likely
that the PM benefits would continue to dominate the total monetized benefits due to the size of the
exposed population and the severity of the associated health effects. Despite our inability to provide
monetized benefits of HAP emission reductions, the total monetized benefits exceed the estimated costs
of the rule by a substantial margin, even when taking uncertainty into account.

Consideration of PM2.5 health co-benefits expected as a result of direct PM2.5 and SO2 emission
reductions is directed by OMB Circular A-4 (p. 26, available at:
http://www.whitehouse.gov/omb/circulars a004 a-4/):

"Your analysis should look beyond the direct benefits and direct costs of your rulemaking and consider
any important ancillary benefits and countervailing risks. An ancillary benefit is a favorable impact of
the rule that is typically unrelated or secondary to the statutory purpose of the rulemaking (e.g., reduced
refinery emissions due to more stringent fuel economy standards for light trucks) while a countervailing
risk is an adverse economic, health, safety, or environmental consequence that occurs due to a rule and
is not already accounted for in the direct cost of the rule (e.g., adverse safety impacts from more
stringent fuel-economy standards for light trucks)."

It is also directed by EPA's Guidelines for Preparation of Economic Analyses (p. 11-2, available at:
http://vosemite.epa.gov/ee/epa/eed.nsf/pages/Guidelines.htmn:

"An economic analysis of regulatory or policy options should present all identifiable costs and benefits
that are incremental to the regulation or policy under consideration. These should include directly
intended effects and associated costs, as well as ancillary (or co-) benefits and costs."

In line with this guidance, the EPA estimates all of the anticipated costs and benefits associated with a
regulatory action, to the extent feasible. We further note that if we were able to fully monetize all of the
benefit categories, the benefits would exceed the costs by an even greater amount than we currently
estimate.

9. Lack of quantification of non-Hg HAP means no benefits.

Comment 33: Commenter 17716 believes that the fact that the benefits of non-Hg HAP are not
quantified means that no benefits exist for these reductions.

Response to Comment 33: This rule is expected to achieve important non-Hg HAP benefits. However,
monetization of non-Hg HAP benefits is limited by currently available data and methods. In summary,
monetization of the benefits of reductions in cancer incidences requires several important inputs,
including central estimates of cancer risks, estimates of exposure to carcinogenic HAP, and estimates of
the value of an avoided case of cancer (fatal and non-fatal). Due to methodology and data limitations,
we did not attempt to monetize the health benefits of reductions in HAP in this analysis. Instead, we
provide a qualitative analysis of the health effects associated with the HAP anticipated to be reduced by
these rules. The EPA disagrees that the health benefits of non-Hg HAP could never be measured. A
well-designed epidemiological study could measure these benefits. The EPA remains committed to
improving methods for estimating HAP benefits by continuing to explore additional concepts of
benefits, including changes in the distribution of risk. Quantitative estimates of these benefits are

653


-------
provided to the extent possible, and our limited ability to monetize these benefits does not indicate that
they are non-existent or less important.

Our treatment of these benefits follows guidance set by OMB Circular A-4 (pp. 26-27, available at:
http://www.whitehouse.gov/omb/circulars a004 a-4/):

"Sound quantitative estimates of benefits and costs, where feasible, are preferable to qualitative
descriptions of benefits and costs because they help decision makers understand the magnitudes of the
effects of alternative actions. However, some important benefits and costs (e.g., privacy protection) may
be inherently too difficult to quantify or monetize given current data and methods. You should carry out
a careful evaluation of non-quantified benefits and costs. Some authorities refer to these non-monetized
and non-quantified effects as "intangible."

It is also in line with EPA's Guidelines for Preparing Economic Analyses (p. 11-3, available at:
http://vosemite.epa.gov/ee/epa/eed.nsf/pages/Guidelines.htmn.

"Benefits and costs that cannot be monetized should, if possible, be quantified (e.g., expected number of
adverse health effects avoided). Benefits and costs that cannot be quantified should be presented
qualitatively (e.g., directional impacts on relevant variables)."

10.	MATS is duplicative of the CSAPR and multiple NAAQS.

Comment 34: Commenter 17761 believes that MATS will duplicate emissions reductions achieved
through the CSAPR and NAAQS implementation.

Response to Comment 34: The EPA disagrees that MATS is duplicative with the CSAPR and
NAAQS. MATS will reduce emissions of HAP emissions not regulated by the aforementioned rules.
Furthermore when the EPA estimates the benefits for rules like MATS, the EPA includes other rules
such as the CSAPR in the "baseline." Any emission changes expected as a result of MATS are
additional emission reductions beyond those regulations (e.g., CSAPR) that were considered to be part
of the baseline.

11.	U.S. EGU mercury emissions are a small contributor to the global pool.

Comment 35: Multiple commenters (17716, 17682, 18484, 18500, 17904 18020, 17754) argue that
reductions of Hg emissions from U.S. EGUs is not a cost-effective method for reducing Hg emissions
since Hg is emitted globally and the contribution from U.S. sources is very small.

Response to Comment 35: The EPA disagrees that controlling Hg emissions from U.S. EGUs is not a
cost-effective method of reducing Hg emissions. The EPA agrees with NACAA (public comment EPA-
HQ-OAR-2009-0234-17620-A1) that "while a global mercury pool does exist, data collected at a
number of U.S. locations over the past decade show that reductions in point source air emissions of
mercury produce substantial improvement in the local and regional environment shortly after those
reductions are implemented. Indeed, ongoing monitoring efforts in a number of states indicate that
mercury levels in fish and other biota have fallen as those states have begun to address sources of
mercury pollution."

In November, 2002, an enhanced air monitoring site was established in Steubenville, Ohio to investigate
source-receptor relationships for Hg deposition in eastern Ohio. The site overlooking the Ohio River

654


-------
was in close proximity to several anthropogenic point sources, including EGUs. The data collected
during this study demonstrated that approximately 70% of the Hg in wet deposition was due to coal
combustion and that a significant portion of the Hg deposited in the immediate vicinity of local EGUs
was directly attributed to those local sources. The University of Michigan researchers concluded that "it
has become evident that near-field impact of coal fired utility boilers on Hg deposition is significant and
underestimated by the models that have been utilized in previous policy decision making."(Keeler et al,
2006) Similarly, wet deposition data collected throughout the Great Lakes over the past decade have
demonstrated distinct regional variability that undercuts any suggestion that local Hg emission efforts
are of no value. Precipitation samples collected in southeastern Michigan showed a 25 to 35% increase
in the Hg concentration between urban sites in Detroit and a rural site 40 miles to the east. This
phenomenon is not limited to the northern part of the country. Studies in south Florida revealed that the
spatial and temporal patterns of wet deposited Hg were also strongly influenced by local sources.
National data show similar variability in deposition rates; Hg deposition rates attributable to U.S. EGU
emissions at the most affected water bodies are eight times the mean rate of such deposition. The EPA's
modeling suggests that the proposed rule will reduce this local excess deposition from U.S. EGUs by
80%). (Gerald J. Keeler, Matthew S. Landis, Gary A. Norris, Emily M. Christianson, and J. Timothy
Dvonch, Sources of Mercury Wet Deposition in Eastern Ohio, USA, pub Environ. Sci. Technol., 2006,
40 (19), pp 5874-5881.)

12. HC1 contribution to acidification of ecosystems.

Comment 36: Commenter 18487 points out that reducing emissions of acid gases will benefit acid
sensitive ecosystems and the fish and wildlife that depend on those ecosystems.

Response to Comment 36: The EPA agrees that acidification poses a significant risk of adverse effects
to fish and wildlife in aquatic and terrestrial ecosystems. Please refer to the EPA's recent Risk and
Exposure Assessment for Review of the Secondary National Ambient Air Quality Standards for Oxides
of Nitrogen and Oxides of Sulfur-Main Content (Final Report available at

http://www.epa.gov/ttn/naaqs/standards/no2so2sec/data/NOxSOxREASep20Q9MainContent.pdf) for a
comprehensive report on those effects including increased Hg methylation in acidified systems. To the
extent that acid gases contribute to acidification, the EPA agrees that those gases pose a risk for
acidification of ecosystems. However, due to data and methodological limitations, the EPA was not able
to quantify those risks and benefits.

655


-------
6M - Impacts and Costs: Air quality co-benefits modeling
Commenters: 17627, 17752, 19686

Comment 1: Commenter 17627 states that the 2005 base year did not include emission reductions that
have already occurred as a result of many enforceable federal and state programs. Additionally, the 2016
emissions are predicated off the IPM-related NODA dated October 2010 and do not include results from
two subsequent NOD As. If the emission estimates were corrected, the benefits would not be overstated
and it is possible that the rule could not be justified on cost considerations.

Response to Comment 1: The EPA disagrees with the commenter's assertion that the benefits are
overstated based on a 2005 base year. The benefits of the rule are computed based on differences
between the 2016 baseline and the 2016 policy case, and not the differences from 2005. Therefore, to
achieve reasonably accurate estimates of benefits, the most important feature of EPA's approach is
having an accurate projection from 2005 to 2016, so that the emissions reductions and economic
downturn referenced by the commenter are included in the future base and therefore not included as part
of the benefits of the rule. These impacts are included in both the 2016 baseline and the 2016 policy case
and therefore are not captured as benefits of the rule. The EPA diligently included the emissions
reductions that have occurred from 2005 to present and the final modeling done for the RIA for this rule
is the best available national information to reflect reductions in emissions that have occurred from 2005
to present. The data used at proposal were updated to reflect the comment process on the CSAPR, for
which a number eastern states provided detailed updates to the EPA's emissions projection assumptions
for EGU, non-EGU point, stationary area, and nonroad mobile sources. All of these comments were
included in the projections used for the final rule. Furthermore, the comment process for this rule
provided an opportunity to make the EPA aware of any other projection changes that were needed for
improving our benefits estimates. In the rare instances where such specific comments were made for this
rule, the EPA included those reductions in the final 2016 projections. The EPA used the best economic
forecasts available at the time the datasets were created. This included the use of Annual Energy
Outlook of 2010 data in the EGU projections. Other updates to point sources included the incorporation
of all known controls in the 2016 baseline, and the inclusion of non-EGU plant closures, federally
enforceable emissions reductions, and consent decrees that have happened since 2005.

Comment 2: Commenter 17752 describes errors found in the IPM file pertaining to two of the
commenter's units which are affected by the proposed rule. The commenter explains that the Big Stone
Plant was shown to have an on-line scrubber in 2011, which it does not. The file also showed an ESP,
while the plant has only a fabric filter and not an ESP. The commenter also explains that the Hoot Lake
Plant Unit 2 does not have any NOx control listed in the file, but it is equipped with low NOx burners
and overfire air. The commenter requests the EPA make corrections to these and any other incorrect
IPM files and determine the true rule impacts.

Response to Comment 2: The EPA thanks the comment for this observation and notes that IPM
modeling for the final rule has been updated to reflect these corrections.

Comment 3: Commenter 19686 states that the rule's technical analysis fails to account for Tribes with
respect to monitoring and modeling. The EPA used the Community Multi-scale Air Quality (CMAQ)
model to estimate the rule's reduction in the incidence of adverse health effects, as well as the estimated
economic value of the reduction in the incidence of adverse health effects. The grid sizes used fail to
account for the considerable variation in the land size of individual Tribes, which can be anywhere
between one to thousands of acres. The smallest lands, because of their size, may be wholly or partially

656


-------
located in areas that heavily influence airflow unlike surrounding jurisdictions (e.g., valleys, mountains),
meaning that CMAQ grid sizes of 12 km and greater may have a hard time modeling the true effects on
local air quality for Tribes. To predict the rule's impact on Tribes more accurately, the commenter
recommends that the EPA redo its CMAQ analysis and use modeling grids no greater than 4 km.

Further, the EPA should use similar size grids for any of its forthcoming rules that may have potential
impacts on Tribes.

In using the CMAQ model, the EPA cites as one uncertainty the "[l]ack of ozone and PM 2.5 monitors
in rural areas" that required the EPA to extrapolate "observed ozone data from data to rural areas." Most
of Indian Country is located in rural areas, meaning that their lands were unrepresented by the modeling
results. Tribal lands located in urban areas are also largely unrepresented since they possess few
monitors to discern the presence and amount of pollutants covered by the rule. Hence, the EPA lacks the
data to make any accurate conclusions about the rule's impact on Tribes. Further, the EPA must get
away from the practice of extrapolating data for Tribal lands for any of its rules and actions.

Response to Comment 3: The EPA agrees with the commenter that the CMAQ modeling with 12 km
grid resolution may provide a lower bound estimate on EGU contribution as higher impacts using finer
grid resolution are possible. The EPA also agrees with the commenter that there may be some variation
in estimated air quality within a 12 km grid cell, but we believe the air quality estimates at 12 km
generally reflect the area within the grid cell. The EPA would like to point out that the application of a
photochemical model at 12 km grid resolution for the entire continental U.S. is more robust in terms of
grid resolution and scale that anything published in literature and represents the most advanced
modeling platform used for a national Hg deposition assessment.

657


-------
6N - Impacts/Costs: Other/Miscellaneous
Commenters: 15002, 15160, 17620, 17884, 17973, 19214

Comment 1: Commenter 15002 recommends the EPA implement a 5-year review cycle for Hg and
other HAP, similar to what is mandated by the CAA for the NAAQS. The commenter notes that
emissions will plateau at current levels due to population increases balanced out by improved emission
controls that become more effective and less expensive. However, the commenter also points out that no
safe level exists for Hg or other HAP.

Response to Comment 1: The EPA welcomes the commenter's observations regarding future emissions
levels and control technology but notes that, while a regular 5-year review schedule is mandated by the
CAA for the NAAQS, the schedule prescribed by the CAA for review of emission standards for Hg and
other HAP calls for a review every 8 years. See CAA section 112(d)(6). The EPA believes that
subsequent periodic reviews will identify any improvements in techniques for the control of Hg and
other HAP, and these will be incorporated as appropriate.

Comment 2: Commenter 17620 asks that the final rule reach a balance between protecting public health
and avoiding unnecessary costs on the regulated community. The commenter notes that the EPA has
projected substantial reductions in the emissions of Hg, HC1, fine PM and SO2, all of which are needed
to protect public health. The commenter further notes that industry testing supports emission standards
of the stringency proposed and the technology to meet the proposed standards has been in use for 10 to
40 years.

Response to Comment 2: The EPA agrees with the commenter's assessment that the rule achieves
important reductions in the emissions of several air pollutants without being unduly burdensome.

Comment 3: Commenter 15160 sees the proposed rule as an important step toward ensuring that the
living and working environments of all Carolinians are reasonably safe and encourages the EPA to
maintain the same level of strictness in the final rule.

Response to Comment 3: The EPA thanks the commenter for their support.

Comment 4: Commenter 17884 sees the proposed rule as having little, if any, health benefit and
believes it may endanger public health and welfare by reducing the disposable income of people for the
necessities of life.

Response to Comment 4: The EPA does not agree with the commenter's assertion that the rule will
achieve little or no health benefit, and the EPA's position is supported by information on the benefits of
the rule documented in the rulemaking record. The commenter also makes an assertion which relies on a
theory that the cost of a rule will result in lost income that will, in turn, result in negative health effects
that offset the positive health effects of the rule. (This is sometimes referred to as a "health-health
tradeoff") The EPA also disagrees with this claim and notes that there are a number of conceptual and
empirical problems with any attempt to quantify the health-health tradeoffs of regulatory action to
control air pollution. Claims about health-health trade-offs rely on questionable applications of cross-
sectional data and ignore key factors that may influence changes in population health risks. Additionally,
marginal decreases in household income caused by the pass-through costs of the regulation are unlikely
to cause large changes in any single aspect of household spending, such as health care. These analyses
also fail to consider that household income may increase if individuals are able to work (or work more)

658


-------
as a result of improved health, offsetting some or all of the pass-through costs of the rule. For these and
other reasons, the EPA's science and economic peer review panels have consistently advised against
incorporating alleged health-health trade-offs in EPA analyses of regulatory effects.

Comment 5: Commenter 17973 states that the fleet of coal-fired EGUs in the U.S. is aged and
inefficient, having operated in most cases without modern controls for 35 years or more. The commenter
considers the proposed rule to be overdue, as all other major source categories of HAP have
implemented controls under MACT requirements already. The commenter believes that a well-
controlled EGU equipped with a baghouse, SO2 scrubber and SCR can meet the proposed standards.

Response to Comment 5: The EPA thanks the commenter for their support.

Comment 6: Commenter 19214 believes HAP emissions reductions beyond present levels are needed
for the U.S. to fulfill the mission under the National Park Service Organic Act to protect national parks
in an unimpaired condition for future generations.

Response to Comment 6: The EPA agrees with the commenter's statement that HAP reductions will
have a positive environmental impact in addition to the health benefits quantified for this regulation.

Comment 7: Commenter 19686 states that to better assess the impact of the rule and any forthcoming
actions by the EPA, they recommend that the EPA provide Tribes with an appropriate number of
monitors of various types to establish baseline monitoring data for criteria pollutants and HAP.

Response to Comment 7: The agency encourages interested tribes to work with the EPA Regional
Offices to determine where monitoring would be appropriate, as monitoring resources are typically
supported with state and tribal air grants.

Comment 8: Commenter 16849 states that even under revised averaging periods, TRONA and DSI is
not a viable option, as is incorrectly stated by the EPA ("IPM Parsed Results - Policy Case," Unplanned
DSI Installations by 2015 includes Asbury: 2076 B1).

Response to Comment 8: The EPA believes that DSI has the potential to be a useful and cost-effective
control technology option for many units. We also understand that it is not an appropriate option for all
facilities. Overall the EPA believes that the technology is most applicable for units burning lower-sulfur
content coal (including, potentially, low-sulfur bituminous coal).

Comment 9: Commenter 17884 states that the EPA erred by failing to consider the negative health and
welfare consequences of its proposed rule. According to the commenter, the proposed rule will have
little, if any, health benefit and will endanger the public and welfare by reducing the disposable income
people will have for the necessities of life. Because the purpose of the CAA is to protect public health
and welfare, failure to consider the negative health consequences is arbitrary and capricious and
otherwise not in accordance with law. See AT&T Corp. v. Iowa Utils. Bd., 525 U.S. 366, 388 (1999)
(invalidating agency interpretation not "rationally related to the goals" of the governing statute).

Response to Comment 9: The EPA disagrees with the commenter that our interpretation of the statute
is in error for the reasons set forth in the proposed rule and this final action. The EPA also does not
agree with the commenter's assertion that the rule will achieve little or no health benefit, and the EPA's
position is supported by information on the benefits of the rule documented in the rulemaking record.
The commenter also makes an assertion which relies on a theory that the cost of a rule will result in lost

659


-------
income that will, in turn, result in negative health effects that offset the positive health effects of the
rule. (This is sometimes referred to as a "health-health tradeoff") The EPA also disagrees with this
claim and notes that there are a number of conceptual and empirical problems with any attempt to
quantify the health-health tradeoffs of regulatory action to control air pollution. Claims about health-
health trade-offs rely on questionable applications of cross-sectional data and ignore key factors that
may influence changes in population health risks. Additionally, marginal decreases in household income
caused by the pass-through costs of the regulation are unlikely to cause large changes in any single
aspect of household spending, such as health care. These analyses also fail to consider that household
income may increase if individuals are able to work (or work more) as a result of improved health,
offsetting some or all of the pass-through costs of the rule. For these and other reasons, the EPA's
science and economic peer review panels have consistently advised against incorporating alleged health-
health trade-offs in EPA analyses of regulatory effects.

660


-------
CHAPTER 7: STATUTORY AND EXECUTIVE ORDERS

7A - Executive Order 12866, Regulatory Planning and Review and Executive Order 13563,
Improving Regulation and Regulatory Review

Commenters: 17638, 17648, 17681, 17702, 17713, 17715, 17721, 17734, 17751, 17757, 17758, 17768,
17806, 17842, 17833, 17868, 17884, 17911, 17917, 17919, 18016, 18018, 18446, 18486, 19042, 19114

1. The EPA did not comply with EO 13563.

Numerous commenters (17638, 17681, 17702, 17713, 17715, 17721, 17751, 17757, 17758, 17842,
17868, 17884, 17911, 17917, 17919, 18106, 18018, 18446, 18486, 19042, 19114) state that the EPA
failed to comply with the requirements of EO 13563.

Comment 1: Multiple commenters (17638, 17713, 17884, 18446, 18486, and 19114) state that the EPA
failed to consider the cumulative impacts of the proposed rules as required by EO 12866 and EO 13563.
Commenter 17638 states the regulation's benefits do not justify its costs nor impose the least burden on
society taking into the costs of cumulative regulations. Commenter 17884 believes the EPA is producing
a series of rule-by-rule RIAs that narrowly define what impacts the specific rule at issue has, which has
the result of minimizing the impact of any one rule and avoiding taking responsibility for the actions
utilities are taking in anticipation of the EPA's entire regulatory agenda. Commenter 18446 cites a report
by the National Economic Research Associates (NERA) that shows that the combination of the
Transport Rule and the Utility MACT Rule will be a serious blow to the economy, causing a net loss of
1.4 million jobs by 2020, and the combination of the two regulations will also cause a substantial
increase in retail electricity prices, with the price increase estimated to top 23 % in some areas of the
country. Commenter 18446 suggests the EPA withdraw the rule until the agency conducts a cumulative
impact analysis.

Commenter 17715 suggests the proposed rule does not take into account harmonization with other
regulations, such as the effect of this rule coupled with future requirements surrounding Coal
Combustion Residuals (CCR), revised NAAQS, regulations surrounding cooling water intake
impingement and entrainment (316(b)) and GHG regulations that will also be affecting sources in
upcoming years.

Commenter 17734 states that there are a large number of related rulemaking efforts coming out in the
near term, including revisions to the NAAQS for PM2.5, ozone, and 1-hour SO2; a new GHG NSPS; and
the recently promulgated CSAPR, which will make it difficult for implementing agencies and affected
facilities to determine the most efficient use of resources to allocate in order to cost-effectively achieve
compliance. The commenter suggests that if the agency can coordinate, reconcile, and harmonize the
overlapping regulatory requirements, it will help to lessen these difficulties.

Commenter 17757 notes that the EPA analysis failed to take into account the impact of each of the
CSAPR and the proposed EGU air toxics rule on the common objective of appropriate and reasonable
emissions control.

Commenter 17842 states that while the rule estimates costs of compliance and anticipated retirements, it
is the collective impact of all emission regulations affecting EGUs that the industry fears will create a
snowballing cost effect, ultimately taking utilities to a point where they would have been better off
investing in other base load generation sources. The commenter believes the proposed Utility MACT

661


-------
rule does not account for these concerns, and the resulting uncertainty places utilities in a very
disagreeable position in terms of generation planning.

Commenter 17917 states that the EPA should consider the cumulative effects of the host of proposed
and recently final rules, including these proposed rules, to the power utility and manufacturing sectors,
not to mention ratepayers and others affected. The commenter believes these rules neither promote
economic growth, competitiveness nor job creation.

Commenter 17919 states the EPA should address the timeframe and content of overlapping rules for the
power sector, beginning with Utility MACT. The commenter believes rules should impose the "least
burden," taking into account the multiple and overlapping rules facing the power sector. Where the EPA
has the capacity for flexibility, such as in the control of non-Hg HAP, subcategorization, determination
of the MACT floor, and other areas, the commenter believes the EPA should do so. The commenter
notes that numerous rules promulgated or expected to be promulgated in 2010-2012, in conjunction with
Utility MACT, means that the generating units subject to these rules would either have to undertake the
installation of extensive retrofits on an unrealistic timeframe or else shutdown entirely. The commenter
suggests that the EPA extend the compliance period in the proposed rule to allow for such retrofits.

Commenters 17806 and 17833 state that the proposed rule, in addition to the NSPS for GHG emissions,
new regulations for handling coal ash, and new revisions to the ozone and PM NAAQS, will have a
negative impact on the economies of many regions. Commenters add that the EPA has not described
how the regulations interrelate or whether they have a collective benefit. Commenter requests that the
agency withdraw all the proposals mentioned and conduct a cumulative impact assessment.

Response to Comment 1: The Agency did not prepare a cumulative impact analysis to accompany the
rule for the following reasons: 1) the various EO requirements that the Agency must comply with
require us to estimate impacts specific to this rule; 2) decision makers and the public need to know the
impacts specific to a particular rule in order to judge the merits of the regulation; 3) estimates specific to
a particular rule are more transparent than those from a cumulative impact analysis. A cumulative
impact analysis lumps several regulations together and can potentially mask a high-cost/low benefit
regulation among other rules that may have large net benefits. By analyzing each regulation separately,
EPA makes clear statements about what impacts, costs, and benefits will be generated as a result of this
particular regulation.

This does not, however, mean EPA has failed to consider cumulative impacts of the regulation. The
inclusion of CSAPR and other regulatory actions (including federal, state, and local actions) in the IPM
base case reflects the level of controls that are likely to be in place in response to other requirements
apart from MATS. This base case provides meaningful projections of how the power sector will respond
to the cumulative regulatory requirements for air emissions, while isolating the incremental impacts of
MATS. These results are presented in Chapter 3 of the RIA.

Additionally, the Agency does reflect on the broader cumulative impacts of our regulations. In March
2011, EPA issued the Second Clean Air Act Prospective Report which assessed at the benefits and costs
of regulations pursuant to the 1990 Clean Air Act Amendments. The study examines the cumulative
impact of these regulations (found at http://www.epa.gov/air/sect812/febl 1/summaryreport.pdf). As
shown in the report, the direct benefits from the 1990 Clean Air Act Amendments reach almost $2
trillion for the year 2020, a figure that dwarfs the direct costs of implementation ($65 billion). The full
report is at http://www.epa.gov/air/sect812/prospective2.html.

662


-------
The direct benefits of the 1990 Clean Air Act Amendments and associated programs significantly
exceed their direct costs, which means economic welfare and quality of life for Americans were
improved by passage of the 1990 Amendments. The wide margin by which benefits exceed costs
combined with extensive uncertainty analysis suggest it is very unlikely this result would be reversed
using any reasonable alternative assumptions or methods. This conclusion is likely to also be attributable
to this rule as shown in the RIA.

In implementing rules such as the MATS, emission controls may lead to reductions in ambient PM2.5 and
ozone below the NAAQS for PM and ozone in some areas and assist other areas with attaining these
NAAQS. Although both RIAs calculate PM and ozone costs and benefits, it is important to note that
there are key differences in the design and analytical objectives of a NAAQS RIA and one for a rule
such as MATS. The NAAQS RIAs illustrate the potential costs and benefits of attaining a new air
quality standard nationwide based on an array of emission control strategies for different sources. In
short, NAAQS RIAs hypothesize, but do not predict, the control strategies that states may choose to
enact when implementing a NAAQS. The setting of a NAAQS does not directly result in costs or
benefits, and as such, the NAAQS RIAs are merely illustrative and are not intended to be added to the
costs and benefits of other regulations that result in specific costs of control and emission reductions.
Some costs and benefits estimated in the final MATS RIA account for the same air quality
improvements as estimated in the illustrative PM2.5 and ozone NAAQS RIA, but these effects are only
counted once when considering cumulative costs and benefits.

Comment 2: Commenter 19042 suggests the EPA failed to follow the guidelines in EO 13563 for
assessing the impact of the proposed regulation on federal agencies as well as state and local
governments. The commenter cites OMB Circular A-4, suggesting that the EPA is required to consider
as part of its RIAs, significant increases in the federal government's administrative costs. The
commenter believes that if the EPA's Utility MACT standards result in higher electricity costs for itself
and other federal agencies, thereby making it more difficult to administer government programs, such
costs are considered administrative in nature.

Response to Comment 2: The EPA disagrees with the commenter's assertion that the agency failed to
follow the guidelines in EO 13563 and OMB Circular A-4. Circular A-4 requires the analysis of
government administrative costs or savings when those effects are expected to be significant. The EPA's
analysis of costs does include direct costs to government-owned facilities that are subject to regulation
under the rule. The agency does not believe that the indirect administrative costs are large enough to
have a significant impact.

Comment 3: Commenters 17702 and 18018 believe the EPA has an obligation to maintain consistency
in its regulations when addressing court vacaturs and remands of CAIR and CAMR. The commenters
also state the EPA increased the stringency of both the Clean Air Transport Rule (CATR) and the
proposed utility air toxic rule beyond what is necessary to address the deficiencies identified by the
Courts.

Response to Comment 3: The EPA disagrees with the commenters' assertions concerning CAMR and
notes that comments on CAIR are outside the scope of this action. The D.C. Circuit Court vacated, not
remanded, CAMR because the Court determined that the EPA had not properly delisted EGUs from the
section 112 list of sources and the EPA did not have the authority to regulate HAP emissions under
section 111 for source categories listed under section 112. {New Jersey v. EPA, 517 F.3d 574, 583 (D.C.
Cir. 2008).) The EPA is finalizing standards for EGUs under section 112(d) of the CAA and we
maintain that our action is consistent with the D.C. Circuit Court's decision.

663


-------
Comment 4: Commenter 17638 states that the EPA did not respond to a Congressional inquiry
regarding statements that the EPA coordinated with DOE, FERC, the National Electric Reliability
Council (NERC), Public Utility Commissions (PUCs), and Regional Transmission Organizations
(RTOs).

Response to Comment 4: The EPA is separately working on those responses. Status of the EPA
responses to Congressional inquiry does not affect the EPA's authority or responsibility under section
112 to issue final emission standards for EGUs.

Comment 5: Several commenters (17868, 17758, 17911, 18106) state the EPA has not proposed any of
the regulatory options to reduce burdens and maintain flexibility in order to comply with the EO
requirements to consider flexible approaches. Commenter 17911 notes the EPA failed to respond to the
recommendation for less intrusive regulatory approaches suggested during the SBAR Panel process.
Commenter 17758 states that many of the proposed measures for demonstrating compliance impose
unnecessary burdens and excessive costs in contradiction to the EO. The commenter recommends these
restrictive requirements be removed.

Response to Comment 5: The EPA believes it has appropriately incorporated provisions that provide
regulated EGUs with the maximum flexibility permitted by the statute to reduce emissions and achieve
compliance in the most cost-effective and efficient manner possible for the particular EGU, while
assuring that significant reductions in emissions and the health benefits attendant to such reductions will
be realized. Examples include: (1) the work practice standards for dioxin/furans and non-dioxin/furan
organic HAP, (2) the EPA's treatment of variability in setting emission standards, (3) the provisions
allowing emissions averaging to demonstrate compliance, (4) the availability of surrogates to determine
compliance, (5) the choice for existing sources to comply with either input-based or output-based
emission limitations, (6) the statutory eligibility for a 1-year extension to comply with the rule in the
event that the additional time is necessary for installation of controls, consistent with the statutory
requirements of section 112(i)(3), and (7) the provision of an affirmative defense to any malfunction.

Comment 6: Commenter 17751 states the EPA has not demonstrated that it has considered the relative
costs of achieving the benefits associated with the proposed regulation affecting the EGU sector by
means of alternative regulatory strategies.

Response to Comment 6: Although the proposed rule did not include a full quantitative analysis of a
more and less stringent regulatory alternative, a quantitative analysis of costs was included in the MACT
Floor TSD to illustrate the feasibility of the beyond-the-floor standard for lignite. The analysis of the
floor for all subcategories constitutes a less stringent alternative than the proposed standard.

Additionally, the proposal includes a qualitative discussion of a number of alternative approaches such
as a health-based standard and alternative subcategorization.

Comment 7: Commenter 17721 suggests that the proposed rule would negatively impact innovation if
ACI technology remains the only EPA-endorsed Hg control technology. The commenter suggests that
the proposed rule include a variety of Hg control systems, including DLPS technology.

Response to Comment 7: The commenter is incorrect - the EPA does not endorse any specific type of
pollution control technology, nor does it mandate or prohibit technologies. The MACT standard is an
emission-based standard that is established by considering the maximum emission reductions currently
achieved by existing EGUs. Individual facilities are free to use whatever technology they wish in order
to achieve this standard. Contrary to the commenter's belief, the MACT standard encourages innovation

664


-------
by spurring companies to develop more effective and efficient methods for achieving the necessary
emission reductions.

Comment 8: Commenter 17681 states that the EPA must explain how the proposed rule utilizes the best
techniques to accurately quantify present and future benefits. Commenter 17681 states that the EPA
must explain how the proposed rule ensures the objectivity of scientific and technological information
and processes to support the action.

Response to Comment 8: The EPA recognizes its obligations under EO 13563 to use the best available
techniques to accurately quantify both present and future costs and benefits as well as to ensure the
objectivity of scientific and technological information and processes used in its analysis. As such, the
EPA relies upon guidance from its independent scientific and economic review panels and employs peer
reviewed processes and technical literature in completing its analyses. All necessary documentation is
provided in the RIA and technical support materials accompanying the final rule.

Comment 9: Commenter 17868 acknowledges that the EPA has discretion in developing utility air
toxics under section 112, and that EO 13653 provides important guidance as to use of this discretion.
The commenter believes the projected cost for the rule is significant while providing only minimal
benefits from the direct reduction of HAP. The commenter notes that 99.99% of the benefits from the
proposed rule will result from co-benefits associated with estimated reductions of SO2 and NOx,
resulting in lower ambient PM2.5 and ozone levels; however, these co-benefits are expected to occur
following the implementation of other CAA requirements in progress.

Response to Comment 9: The EPA disagrees with the commenter's assertion that the benefits achieved
from this rule are expected to occur from the implementation of other CAA requirements. In
implementing rules such as the MATS, emission controls may lead to reductions in ambient PM2.5 and
ozone below the NAAQS for PM and ozone in some areas and assist other areas with attaining these
NAAQS. Although both RIAs calculate PM and ozone costs and benefits, it is important to note that
there are key differences in the design and analytical objectives of a NAAQS RIA and one for a rule
such as MATS. The NAAQS RIAs illustrate the potential costs and benefits of attaining a new air
quality standard nationwide based on an array of emission control strategies for different sources. In
short, NAAQS RIAs hypothesize, but do not predict, the control strategies that States may choose to
enact when implementing a NAAQS. The setting of a NAAQS does not directly result in costs or
benefits, and as such, the NAAQS RIAs are merely illustrative and are not intended to be added to the
costs and benefits of other regulations that result in specific costs of control and emission reductions.
Some costs and benefits estimated in this RIA account for the same air quality improvements as
estimated in the illustrative PM2.5 and ozone NAAQS RIA, but these effects are only counted once when
considering cumulative costs and benefits. The EPA believes that to properly understand the impacts of
this rule, it is equally important to identify the co-benefits from reductions in PM and ozone as it is to
identify the direct benefits resulting from reductions in HAP.

Comment 10: Commenter 17638 believes the EPA has not provided sufficient time for the public to
meaningfully participate in this rulemaking, and the EPA's adherence to the November finalization date
precludes the EPA from meaningfully understanding and responding to comments that will be provided.
The commenter believes if the EPA does not appropriately change this schedule, the EPA's actions are
(and will be) arbitrary and capricious, and a violation of the Administrative Procedure Act. At a
minimum, the commenter suggest the EPA must explain how its actions are consistent -with the
'"General Principles" and "Public Participation" directives of EO 13563.

665


-------
Response to Comment 10: The EPA is mindful both of its obligation to provide an opportunity for
public comment and of its obligation to proceed with this rule in a timely manner, but disagrees with the
commenter's assertion that it has acted arbitrarily or capriciously with regard to these obligations. The
agency is obligated to finalize the MATS by December 16, 2011, consistent with a consent decree. This
date reflects a 30-day extension the EPA obtained from the original November 16, 2011 deadline. The
proposed rule was signed on March 16, 2011 and the public comment period was scheduled to close on
July 5, 2011. The EPA extended the comment period an additional 30 days to close August 4, 2011.
Agency staff began reviewing comments and identifying key issues prior to the close of the comment
period. Additionally, the EPA held three public information sessions in Chicago, Atlanta and
Philadelphia during the month of May where the public was able to provide comment on the rule. The
EPA believes that its approach to public comments meets or exceeds both the letter and spirit of the
EO's guidance on public participation.

Comment 11: Commenter 17702 believes the EPA increased the stringency of the proposed rule
without regard to the lack of additional health benefits that might accrue or additional costs that will be
incurred by the public. The commenter instead states that the EPA should use its discretion to minimize
the cost of the rule while still providing for safety of the public.

Response to Comment 11: The EPA disagrees with the commenter and notes that under the CAA, the
agency has limited discretion in setting a MACT floor standard. The MACT floor standard is a
technology-based standard based on the performance of existing sources in the regulated source
category. It provides the minimum level of HAP emission control required for new and existing sources.
The MACT floor for new sources is equivalent to the level of HAP emission control achieved by the
best-controlled similar source, and the MACT floor for existing sources is the average level of HAP
emission control achieved by the top 12% of sources each category or subcategory with 30 or more
sources and the best performing 5 sources for each category or subcategory with less than 30 sources.
Based on the requirements of the CAA, the EPA can only consider economic, environmental, and health
impacts when setting a standard more stringent than the MACT floor. Although the EPA explored
several alternatives for standards beyond the MACT floor, ultimately, only the low rank virgin coal
subcategory was subject to a more stringent standard.

2.	The EPA did comply with EO 13563.

Comment 12: Commenter 17648 states that the proposed rule complies with EO 13563 by producing
benefits that far exceed its costs and promoting economic and job growth. The commenter believes the
EPA also complied with the other requirements of the EO by involving the public, employing where it
can flexible approaches such as averaging, establishing performance based standards, relying on sound
objective science, requiring coordination and harmonization of regulatory actions and the promotion of
innovation.

Response to Comment 12: The EPA thanks the commenter for these observations.

3.	Legal considerations and EO 12866 and 13563.

Comment 13: Commenter 17768 believes the EPA has the legal authority to reinterpret "appropriate" to
allow for the consideration of costs and benefits, as well as the statutory authority to consider net
benefits under section 112(d), and should do so to best adhere to the principles of EO 12866 and 13653,
which instruct agencies to maximize net benefits unless a statute requires another regulatory approach.

666


-------
Comment 14: Commenter 17842 encourages the EPA to consider the overall objective of section
112(n) to reduce Hg emissions while considering the call of EO 13563 to "propose or adopt a regulation
only upon a reasoned determination that its benefits justify its costs."

Response to Comments 13 - 14: The Executive Orders supplement but cannot modify or diminish
statutory requirements. The EPA believes the agency's interpretations of section 112(n)(l) and 112(d)
constitute reasonable interpretations of the statute. While we agree that the cited executive orders direct
the EPA to maximize benefits and minimize costs to regulated industries, we believe that we have done
so within the constraints imposed by the CAA.

667


-------
7B - Paperwork Reduction Act

No comments were received specifically on the Paperwork Reduction Act (PRA) requirements, although
the PRA is mentioned in the context of some comments regarding another topic and have been
addressed as appropriate.

668


-------
7C - Regulatory Flexibility Act (RFA), as Amended by the Small Business Regulatory
Enforcement Fairness Act of 1996 (SBREFA)

Commenters: 10987, 16705, 17004, 17400, 17608, 17648, 17689, 17712, 17805, 17817, 17868, 17885,
17911, 18032, 19094, 19121, 8443

1.	General.

Comment 1: Commenters 16705 and 17400 express concern that smaller utilities and those in rural
areas will be unable to get vendors to respond to their requests for proposals, since they will be able to
make more money serving larger utilities.

Response to Comment 1: The preamble to the proposed rule (76FR 25054, May 3, 2011) provides a
detailed discussion of how the EPA determined compliance times for the proposed rule. The EPA has
provided pursuant to section 112(i)(3)(A) the maximum 3-year period for sources to come into
compliance. Sources may also seek a 1-year extension of the compliance period from their Title V
permitting authority if the source needs that time to install controls. CAA section 112(i)(3)(B). If the
situation described by commenters (i.e., where smaller utilities and those in rural areas are less able to
get vendor responses to requests for proposals than larger utilities) results in the source needing
additional time to install controls, they would be in a position to request the 1-year extension.

2.	Concerns with SBAR Panel.

Comment 2: Multiple commenters (8443, 10987, 17689, 17712, 17817, 17885, 17868) believe Small
Entity Representatives (SERs) were not provided with regulatory alternatives including descriptions of
significant regulatory options, differing timetables, or simplifications of compliance and reporting
requirements, and subsequently presented with an opportunity to respond. Commenters reference the
Report of the SBAR Panel, citing the following text: "SERs stated that they do not believe they were
provided the opportunity for effective participation in the Federal regulatory process as required by
SBREFA."

Comment 3: Commenter 17608 believes the EPA's formal SBAR Panel notification and subsequent
information provided by the EPA to the panel did not include information on the potential impacts of the
rule as required by section 609(b)(1). The commenter states that such information was not provided until
the EPA's submission to OMB/OIRA under EO 12866, after consultation with the SERs was complete.

Comment 4: Several commenters (8443, 17608, 17868) suggest that the EPA's rulemaking schedule
put pressure on the SBAR Panel through the abbreviated preparation for the panel. Commenters 8443
and 17868 note that only one panel meeting was provided and after that meeting, Panel members were
given a mere 14 days to prepare written comments on an incredibly complex topic. Commenters note
that the lack of a pre-panel consultation resulted in the lack of SER involvement with the EPA to draft
outreach materials and participate meaningfully.

Comment 5: Commenters 17608 and 17868 state that the EPA did not identify regulatory alternatives
for the SBAR Panel to consider. The commenters state the EPA did not present a proposed regulatory
approach with sufficient detail for SERs to identify potential economic effects of suggest specific
regulatory alternatives; it had only presented them with broad discussions and raw data upon which the
EPA would eventually make discretionary judgments. Commenters do not believe that the EPA's

669


-------
response to the SBAR Panel concerns regarding the deficiencies in the process relieves the EPA of its
obligations under section 609(b).

Comment 6: Several commenters (8443, 17608, 17911) express concerns that the EPA did not provide
participants more than cursory background information on which to base their comments. Commenter
17608 states that the EPA did not provide deliberative materials, including draft proposed rules or
discussions of regulatory alternatives, to the SBAR Panel members. The commenter believes such
materials could have guided the Panel's deliberations towards regulatory alternatives that minimize the
burden on small entities.

Comment 7: Commenter 17608 states the SBAR Panel Report does not meet the statutory obligation to
recommend less burdensome alternatives. The commenter suggests the EPA Panel members declined to
make recommendations that went further than consideration or investigation of broad regulatory
alternatives, with the exception of those recommendations in which the EPA rejected alternative
interpretations of the CAA section 112 and relevant court cases. The commenter does not believe the
Panel was provided with information necessary to make recommendations beyond a restatement of the
EPA's existing obligations or to evaluate specific regulatory decisions and the impacts of those
decisions on particular small entities or small entities in general.

Comment 8: Commenters 17868 and 17911 note that the EPA did not respond to the concerns of the
small business community, the Small Business Administration (SBA), or OMB, ignoring concerns
expressed by the SER panelists. Commenter 17868 notes specifically that the EPA did not respond
regarding the 3-year compliance deadline and by not acting upon OMB's suggestions to meet again
before the rule was proposed.

Comment 9: Commenter 19121 believes the EPA failed to convene required meetings and hearings
with affected parties as required by law for small business entities.

Comment 10: Commenter 8443 notes that public power accounts for about 16% of all kW-hr sales to
retail electricity consumers, approximately 46% of the MW-hr of electricity produced by public power
systems are generated using coal, and more than 90% of public power utility systems meet the definition
and qualify as small businesses under the SBREFA, giving more importance to the Panel.

Response to Comments 2 -10: The RFA requires that panels collect advice and recommendations
from SERs on the issues related to:

-	the number and description of the small entities to which the proposed rule will apply;

-	the projected reporting, record keeping and other compliance requirements of the proposed rule;

-	duplication, overlap or conflict between the proposed rule and other federal rules; and

-	alternatives to the proposed rule that accomplish the stated statutory objectives and minimize any
significant economic impact on small entities.

The RFA does not require a covered agency to create or assemble information for SERs or for the
government panel members. Although section 609(b)(4) requires that the government panel members
review any material the covered agency has prepared in connection with the RFA, the law does not
prescribe the materials to be reviewed. The EPA's policy, as reflected in its RFA guidance, is to provide

670


-------
as much information as possible, given time and resource constraints, to enable an informed panel
discussion. In this rulemaking, because of a court-ordered deadline, the EPA was unable to hold a pre-
panel meeting but still provided SERs with the information available at the time, held a standard Panel
Outreach meeting to collect verbal advice and recommendations from SERs, and provided the standard
14-day written comment period to SERs. The EPA received substantial input from the SERs, and the
Panel report describes recommendations made by the Panel on measures the Administrator should
consider that would minimize the economic impact of the proposed rule on small entities. The EPA
believes it has properly complied with-the RFA.

3. Impacts on small businesses.

Comment 11: Commenter 17004 requests that the EPA work with utilities such that new regulations are
as flexible and cost efficient as possible.

Response to Comment 11: In developing the final rule, the EPA has considered all information
provided prior to, as well as in response to, the proposed rule. The EPA has endeavored to make the
final regulations flexible and cost efficient while adhering to the requirements of the CAA.

Comment 12: Commenter 17868 is concerned about the ability of small entities or nonprofit utilities
such as those owned and/or operated by rural electric co-op utilities, and municipal utilities to comply
with the proposed standards within 3 years. The commenter believes that the EPA disregarded the SER
panelists who explained that under these current economic conditions they have constraints on their
ability to raise capital for the construction of control projects and to acquire the necessary resources in
order to meet a 3-year compliance deadline.

Response to Comment 12: The preamble to the proposed rule (76 FR 25054, May 3, 2011) provides a
detailed discussion of how the EPA determined compliance times for the proposed rule. The EPA has
provided pursuant to section 112(i)(3)(A) the maximum 3-year period for sources to come into
compliance. Sources may also seek a 1-year extension of the compliance period from their Title V
permitting authority if the source needs that time to install controls. CAA section 112(i)(3)(B). If the
situation described by commenters (i.e., where small entities or nonprofit utilities constraints on ability
to raise capital for construction of control projects and to acquire necessary resources) results in the
source needing additional time to install controls, they would be in a position to request the 1-year
extension.

Comment 13: Commenters 17868 and 18032 believe the EPA did not adequately consider the
disproportionately large impact on smaller generating units. The commenters note the diseconomies in
scale for pollution controls for such units. Commenter 17868 notes the rule will create a more serious
compliance hurdle for small communities that depend on coal-fired generation to meet their base load
demand. The commenter notes that by not subcategorizing units, the EPA is dictating a fuel switch due
to the disproportionately high cost on small communities.

Commenter 18032 believes the MACT and NSPS standards are unachievable by going too far without
really considering the impacts on small municipal units, as public powers is critical to communities,
jobs, economic viability and electric reliability.

Commenter 17868 believes that the EPA has not fully recognized the number of small entities that are
impacted by the rule and underestimated the impacts of the proposed rule on smaller utilities despite the
SER panel.

671


-------
Comment 14: Commenter 19094 is a generating and transmissions electric cooperative which qualifies
as a small entity and believes the proposed rule will ultimately result in increased electricity costs to its
members and will negatively impact the economies of the primarily rural areas that they serve.

Comment 15: Commenter 17648 believes there is no legal or factual basis for creating subcategories or
weaker standards for state, tribal, or municipal governments or small entities that are operating obsolete
units, particularly given the current market situation and applicable equitable factors. The commenter
suggests both the EPA's and SBA's analyses focus exclusively on the effects on entities causing HAP
emissions and primarily on those operating obsolete EGUs, and fail to consider either impacts on
downwind businesses and governments or the positive impacts on small entities and governments
owning and operating competing, clean and modern EGUs.

Response to Comments 13 -15: The EPA disagrees with the commenters' belief that the impacts on
smaller generating units were not adequately considered when developing the proposed rule. The EPA
determined the number of potentially impacted small entities and assessed the potential impact of the
proposed action on small entities, including municipal units. A similar assessment was conducted in
support of the final action. Specifically, the EPA estimated the incremental net annualized compliance
cost, which is a function of the change in capital and operating costs, fuel costs, and change in revenue.
The projected compliance cost was considered relative to the projected revenue from generation. Thus,
the EPA's analysis accounts not only for the additional costs these entities face resulting from
compliance, but also the impact of higher electricity prices. The EPA evaluated suggestions from SERs,
including subcategorization recommendations. In the preamble to the proposed rule, the EPA explains
that any basis for subcategorizing should be related to an effect on emissions, rather than some
difference which does not affect emissions performance. The EPA does not see a distinction between
emissions from smaller generating units versus larger units. One commenter (17648) believes that there
is no legal or factual basis for creating subcategories or weaker standards for state, tribal, or municipal
governments or small entities that are operating obsolete units. The commenter points out that relaxation
in standards would not only harm downwind governments and small businesses who incur higher labor
costs due to pollution, but will harm other small businesses and state, tribal and local governments
developing or operating generation facilities using modern and less polluting generation technologies.
The EPA acknowledges and generally agrees with the commenter's assertion.

Comment 16: Commenter 18032 notes that the EPA recognizes LEEs in the rule such that they should
receive less onerous monitoring requirements; however, the EPA does not recognize that small and
LEEs also need and merit more flexible and achievable pollution control requirements. The commenter
notes that the capital costs for emissions control at small-sized utility units is disproportionately high
due to inefficiencies in Hg removal, space constraints for control technology retrofits, and the fact that
small units have fewer rate base customers upon which to spread these costs. The commenter cites the
Michigan Department of Environmental Quality report titled "Michigan's Mercury Electric Utility
Workgroup, Final Report on Mercury Emissions from Coal-Fired Power Plants," (June 2005). The
commenter notes that the EPA has addressed such concerns previously, citing the RIA for the 1997 8-
hour ozone standard. The commenter also suggests smaller utility systems generally have less capital to
invest in pollution control than larger, investor-owned systems, due to statutory inability to borrow from
the private capital markets, statutory debt ceilings, limited bonding capacity, borrowing limitations
related to fiscal strain posed by other, non-environmental factors, and other limitations.

Response to Comment 16: The EPA acknowledges its proposal of reduced monitoring requirements for
existing units that qualify as low emitting EGUs. Although the EPA does not believe that reduced
pollution control requirements are warranted for LEEs, including small entity LEEs, we believe that

672


-------
flexible and achievable pollution control requirements are promoted through alternative standards,
alternative compliance options, and emissions averaging as a means of demonstrating compliance with
the standards for existing EGUs.

Comment 17: Commenter 8443 believes that the EPA should develop more limited monitoring
requirements for small EGUs. The commenter notes small entities do not possess the monetary
resources, manpower, or technical expertise needed to operate cutting-edge monitoring techniques such
as Hg CEMS and PM CEMs. The commenter notes the EPA could have identified monitoring
alternatives to the SBAR panel for consideration.

Response to Comment 17: The EPA provided monitoring alternatives to using PM CEMS, HC1 CEMS,
and Hg CEMS in its standards. The continuous compliance alternatives would be available to all
affected sources, including small entities. As monitoring alternatives to use of PM CEMS and HC1
CEMS, sources would be allowed to conduct additional performance testing. Sorbent trap monitoring
would be allowed in lieu of Hg CEMS.

4. The EPA did not comply with the RFA.

Comment 18: Commenter 17608 believes the EPA has not sufficiently complied with the requirements
of the RFA or adequately considered the impact this rulemaking would have on small entities. The
commenter believes the EPA has not given itself the opportunity to engage in meaningful outreach and
consultation with small entities and therefore recommends that the EPA seek to revise the court-agreed
deadlines to which this rulemaking is subject, re-convene the SBAR panel, prepare a new initial
regulatory flexibility analysis (IRFA), and issue it for additional public comment prior to final
rulemaking.

Commenter 17608 believes the IRFA does not sufficiently consider impacts on small entities as
identified in the SBAR Panel Report. The commenter believes it is not apparent that the EPA considered
the recommendations of the Panel. The commenter believes the description of significant alternatives in
the IRFA is almost entirely quoted from the SBAR Panel Report, which the commenter does not believe
is an adequate substitute for the EPA's own analysis of alternatives. The commenter also notes the EPA
does not discuss the potential impacts of its decisions on small entities or the impacts of possible
flexibilities. Where the EPA does consider regulatory alternatives in principle, the commenter believes it
does not provide sufficient support for its decisions to understand on what basis the EPA rejected
alternatives that may or may not have reduced burden on small entities while meeting the stated
objectives of the rule. Additionally, the commenter notes that the EPA did not evaluate the economic or
environmental impacts of significant alternatives to the proposed rule.

Commenter 17608 believes that the EPA's stated reasons for declining to specify or analyze an area
source standard are inadequate under the RFA. The commenter believes the EPA must give serious
consideration to regulatory alternatives that accomplish the stated objectives of the CAA while
minimizing any significant economic impacts on small entities and that the EPA has a duty to specify
and analyze this option or to more clearly state its policy reasons for excluding serious consideration of
a separate standard for area sources.

Commenter 17608 suggests that the EPA reconvene the SBAR Panel to solicit more meaningful
consultation with the SERs; the EPA prepare an IRFA that includes descriptions of specific regulatory
alternatives, the effects on small entities of the regulatory alternatives, and the policy reasons for
selected among them; and the EPA release the IRFA for additional public comment before making any

673


-------
decisions about the EPA's preferred options for final rulemaking. The commenter recognizes that the
EPA will have to request of the litigants and the court an extension of the timeline for final rulemaking
but feels strongly that this action is necessary.

Comment 19: Commenter 17805 believes the EPA did not fully consider the subcategorization of
sources such as boilers designed to burn lignite coals versus other fossil fuels, especially in regard to
non-Hg metal and acid gas emissions. The commenter references the SBAR Panel Report suggestion
provided in the preamble of the proposed rule that the EPA consider developing an area source versus
major source distinction for the source category and the EPA's response.

Comment 20: Commenter 17868 is concerned that the recommendations made by the SER participants
were ignored and not discussed in the rulemaking. Specifically, the commenter notes the EPA did not
discuss subcategorizing by age, type of plant, fuel, physical space constraints or useful anticipated life of
the plant. Nor did the EPA provide any opportunity for smaller emitters to use GACT—often used in
other EPA MACT regulations to alleviate the regulatory costs and operational difficulties that would
have burdened other small businesses including dry cleaners, metal fabricating, metal finishing, and
others.

Comment 21: Commenter 17817 believes it is likely that different numerical or work practice standards
are appropriate for area sources of HAP, just as in other rulemakings such as the RICE rule, and that the
EPA would have provided the opportunity for small entities to make such demonstration had they
followed their own regulatory requirements.

Response to Comments 18-21: The EPA disagrees with one commenter's (17608) assertion that the
agency has not complied with the requirements of the RFA. The EPA complied with both the letter and
spirit of the RFA, even under the court-ordered deadline. For example, the EPA notified the Chief
Counsel for Advocacy of the SBA of its intent to convene a Panel; compiled a list of SERs for the Panel
to consult with; and convened the Panel. The Panel met with SERs to collect their advice and
recommendations; reviewed the EPA materials; and drafted a report of Panel findings. The EPA further
disagrees with the commenter's assertion that the EPA's IRFA does not sufficiently consider impacts on
small entities. The EPA's IRFA, which is included in chapter 10 of the RIA for the proposed rule,
describes, among other things, the economic impact of the proposed rule on small entities and the
Panel's findings. The economic impact of the final rule on small entities is included in chapter 7 of the
RIA for the final rule.

Several commenters (17608, 17805, 17868, and 17817) are concerned that recommendations made by
the SERs were ignored and not considered or discussed in the proposed rulemaking. Specifically,
commenters cite SER recommendations regarding subcategorization and separate standards for area
sources. The EPA disagrees with the commenters. The preamble to the proposed standards includes
detailed discussion of how the EPA determined which subcategories and sources would be regulated (76
FR 25036-25037, May 3, 2011). In that discussion, the EPA explains the rationale for its proposed
subcategories based on five unit design types. In addition, the EPA acknowledges the subcategorization
suggestions from the SERs and explains its reasons for not subcategorizing on those bases. The
preamble to the proposed standards also includes a discussion of the SERs' suggestion that area source
EGUs be distinguished from major-source EGUs and the EPA's reasons for not making that distinction
(76 FR 25020-25021, May 3, 2011).

One commenter (17608) suggests that the EPA pursue an extension of the timeline for final rulemaking
such that the SBAR Panel can be reconvened and a new IRFA can be prepared and released for public

674


-------
comment prior to the final rulemaking. The EPA entered into a Consent Decree to resolve litigation
alleging that the EPA failed to perform a non-discretionary duty to promulgate CAA section 112(d)
standards for EGUs. American Nurses Ass 'n v. EPA, 08-2198 (D.D.C.). That Consent Decree initially
required the EPA to sign the final MATS rule by November 16, 2011, but the EPA negotiated a 30-day
extension of the deadline with the plaintiffs in the litigation consistent with the requirements of the
modification provision of the Consent Decree. If plaintiffs in the American Nurses litigation objected to
an additional extension request, which we believe they would, the agency would have had to file a
motion with the Court seeking an extension of the deadline. Consistent with governing case law, the
agency would have been required to demonstrate in its motion for extension that it was impossible to
finalize the rule by the deadline provided in the Consent Decree. See Sierra Club v. Jackson, Civil
Action No. 01-1537 (D.D.C.) (Opinion of the Court denying EPA's motion to extend a consent decree
deadline). The EPA was able to complete the rule by December 16, 2011; accordingly, the agency had
no basis for seeking a further extension of time.

675


-------
7D - Unfunded Mandates Reform Act of 1995

Commenters: 16859, 17868, 17911, 18023

Comment 1: Commenter 16859 believes the EPA in its proposed rule does not appear to have addressed
the statement in UMRA section 202(a)(2) directing federal agencies to consider direct state
administrative costs and to make this information available to the public. The commenter cites concerns
that state, local and tribal government officials expressed at a meeting with the EPA in October 2010
regarding the potential burden associated with implementing the rule, noting that the EPA did not
respond to these concerns in the proposed rulemaking.

Response to Comment 1: UMRA focuses on mandated costs associated with enforceable duties falling
on states. State administrative costs are not expressly included in UMRA as the type of costs to be
included in analyzing cost impacts to the states. Thus, the EPA does not interpret state administrative
costs to be among mandated costs, and state administrative costs were not addressed in the proposed rule
and also are not addressed in the final rule. The UMRA discussion in the preamble to the final rule
addresses this response to the commenter's concern.

Comment 2: Commenter 17868 suggests the EPA failed to meet the requirements of UMRA as the
proposed rule does not consider significant impacts on small municipalities. These impacts include the
increased cost of power being driven up by the compliance costs of the proposed rule, and the social and
economic impacts of the potential shut down of power plants on municipal governments. The
commenter was unable to find information in the rulemaking record regarding the qualitative and
quantitative assessment of the anticipated costs and benefits of the proposed regulation on local
governments, or an assessment of the disproportionate effect of the rule on regions of the country.

Further, commenter 17868 notes that additional regulatory permitting costs would be incurred by public
power utilities, and therefore any comments submitted by municipal or state governments, including
their electric utilities, be considered under SBREFA and UMRA. The commenter notes that the adverse
cost impacts from the EGU MACT would extend directly to municipal and local government operating
budgets, and that increasing operating costs for such not-for profit power producers would be passed on
directly to rate payers. The commenter also notes that significant increased costs may reduce Payments
in Lieu of Taxes to municipal operating budgets, which could in turn result in cuts to essential
governmental services including emergency services and schools.

Comment 3: Commenter 17911 believes the EPA failed to provide a complete financial analysis of the
cost to communities in the proposed rule. The commenter identifies specific items which the EPA did
not take into account: (1) The impact of the rule on the Payment in Lieu of Taxes received by the
community from the local municipal utility; (2) The additional costs to be borne by city government in
paying for the electricity that they use for powering city government; (3) The additional costs to borne
by the city through the utility for increases in default rates on utility payments; (4) The cost to the city
budget of potential downgrade to municipal bond ratings caused by the city having to take on higher
debt load to pay for the emission upgrades; (5) The disparate impact of the rule on smaller cities and
smaller generating units; and (6) The social and economic impact of the shutdown of municipal power
generation in smaller towns and the resulting increase in power costs on the competitiveness of local
industries and other major employers.

Response to Comments 2-3: The EPA assessed the impact of the proposed and final rule on all
directly-impacted municipalities (those holding covered EGUs). As required by UMRA, the EPA
provided a written statement of the qualitative and quantitative impacts to state, local, and tribal

676


-------
governments, and the private sector. This analysis is presented for all municipalities in section 10.2 of
the RIA for the proposed rule and Chapter 7 of the RIA for the final rule, and specifically for small
municipalities in section 10.1 of the RIA for the proposed rule and section 7.5 of the RIA for the final
rule. Total compliance costs for all government and private sector entities are presented in Chapter 8 of
the proposal RIA and Chapter 3 of the final RIA. In the EPA's analysis, a "small" government
jurisdiction is defined as the government of a city, county, town, district, or special district with a
population of less than 50,000. The EPA estimated the incremental net annualized compliance cost,
which is a function of the change in capital and operating costs, fuel costs, and change in revenue. The
projected compliance cost was considered relative to the projected revenue from generation. Thus, the
EPA's analysis accounts not only for the additional costs these entities face resulting from compliance
with the proposal, but also the impact of higher electricity prices that government entities should face,
and does account for projected early retirements due to the proposal among affected units owned by
government entities. All of these results are included in Chapter 10 of the RIA for the proposed rule and
Chapter 7 of the RIA for the final rule, and detailed results are found in the docket for the rulemaking.

As previously stated, the EPA's analysis of costs includes direct compliance costs to units owned by
states or municipalities that are subject to regulation under the rule. The EPA does not believe that
indirect administrative costs are large enough to have a significant impact. Additionally, while local
governments may incur administrative costs as outlined by the commenter, such costs would be nearly
impossible to estimate with any degree of accuracy due to the unique characteristics of each affected
community and the numerous approaches local governments could take to minimize or offset
administrative costs of the rule.

Comment 4: Commenters 17868 and 17911 express concerns over an apparent lack of communication
from the EPA regarding potential impacts of the proposed rule with state and local governments as
required by UMRA. The commenters discuss these shortcomings with respect to the EPA meeting with
the "Big Ten" on October 7, 2010. Specifically, the commenters submit that the "Big 10" organizations
are unlikely to have stakeholders that will be impacted by the MACT rule, and the commenters are not
aware that any of the state/local governments that the EPA estimates will be impacted by the MACT
rule received any meaningful communications regarding potential impacts."

Response to Comment 4: The EPA disagrees with the commenters that there was a lack of
communication between the EPA and state and local governments regarding potential impacts of the
proposed rule. Although details of the proposed rule had not been established at the time of the October
2010 meeting, the EPA believes that meaningful information was shared with representatives of the state
and local organizations early in the regulatory process. The presentation that the EPA used to overview
the Utility MACT regulatory effort at the October 2010 meeting with the "Big 10" included information
indicating that the EPA was early in the process of developing the proposed action. Specifically, the
presentation included a list of central decision points and potential issues (e.g., MACT floors and
variability, subcategorization, pollutants for which standards would be established) for which decisions
had not yet been made and the EPA was seeking input. That presentation is available in the rulemaking
docket. As pointed out above, even though specific information regarding costs and other consequences
of regulatory alternatives was not available, decisions and issues that would affect costs and other
consequences of regulatory alternatives were presented for discussion at the October 2010 meeting with
the "Big 10." Thus, this process enabled meaningful and timely input by state and local officials.

The EPA also disagrees with the commenters that the "Big 10" organizations are unlikely to have
stakeholders potentially impacted by the MACT rule. As examples, The National Association of Towns
and Townships represent smaller communities, towns and townships, and other suburban and rural

677


-------
localities; the National Association of Counties represents county governments; and the National League
of Cities serves as a resource to and an advocate for the more than 19,000 cities, villages and towns. In
fact, 48 of the 112 state/local governments the EPA estimated to be potentially impacted by the MACT
rule are also small government entities. Further, ten SERs were representatives of small entity
representatives that participated in the SBAR panel process for the proposed rule. Thus, the EPA
disagrees that potentially impacted state/local governments did not receive meaningful communications
regarding potential impacts either directly or through representation in the Federalism consultation
and/or the SBAR panel process.

Comment 5: Commenter 17911 notes that the EPA never responded to suggestions by SERs during
December 2010 that the 3-year timeline proposed by the EPA was both unrealistic and impossible to
meet.

Response to Comment 5: The preamble to the proposed rule (76 FR 25054, May 3, 2011) provides a
detailed discussion of how the EPA determined compliance times for the proposed rule. With respect to
the final rule, the EPA has provided pursuant to CAA section 112(i)(3)(A) the maximum 3-year period
for sources to come into compliance. Sources may also seek a 1-year extension of the compliance period
from their Title V permitting authority if the source needs that time to install controls. CAA section
112(i)(3)(B).

Comment 6: Commenter 17911 states the EPA failed to fully evaluate the unintended consequences of
this rule on local economies, especially in mid-sized and smaller communities where a disproportionate
share of those over 65 and those under the poverty level reside.

Response to Comment 6: The EPA conducted its economic analyses in response to the statutory and
executive orders requirements that it must follow for economically significant rules such as this one. The
agency's analysis included estimates of the increase in retail electricity price both nationally and
regionally, and this analysis shows no increases in retail electricity price above 7% in 2015, and lower
price increases thereafter. Such an analysis is informative to meet the requirements of EO 12898
(Environmental Justice). State and local authorities are best equipped to mitigate impacts related to
increases in electricity rates.

Comment 7: Commenter 18023 states that the EPA's RIA must adhere to UMRA and EO 12866 in
conducting cost-benefit analysis.

Response to Comment 7: The EPA adhered to the requirements of UMRA and EO 12866 in preparing
the cost-benefit analysis that is presented in the RIA for the proposed and final rules. The agency
presented its analysis of the impact of the rule on federal, state, and local government entities in Chapter
10 of the RIA for the proposed rule and Chapter 7 of the RIA for the final rule. This analysis serves as
the written statement that is required under section 202 of the UMRA. Intergovernmental consultations
as required under section 204 were conducted and were placed in the docket for this rulemaking. The
agency explained why this standard was proposed, and alternatives to it, in the preamble for the
proposal. The contents of the RIA are consistent with what EO 12866, and the guidance in OMB
Circular A-4, requires for an RIA.

678


-------
7E - Executive Order 13132, Federalism
Commenters: 16859, 17701, 17791, 17868, 18447
1. Federalism requirements.

Comment 1: Commenter 16859 points out that section 6.(b)(2)(B) of EO 13132 requires that the EPA
provide to the OMB a federalism summary impact statement (FSIS) containing a number of elements,
including a statement of the extent to which the concerns of state and local officials have been met.
Commenter indicates that states continue to remain uncertain of the extent to which the EPA is
considering state administrative costs, including state administrative costs for this proposed utility
MACT rule.

Response to Comment 1: As required by section 6(b)(2)(B) of EO 13132, the EPA provided a FSIS in
its proposed rule and provides an updated impact statement in the preamble to the final rule. The final
rule impact statement presents the EPA's assessment of the compliance costs of the regulatory option
being promulgated on state and local governments. In addition, the statement addresses state and local
officials' uncertainty regarding the extent to which the EPA is considering state administrative costs. We
note that state administrative costs are not expressly included in the Federalism guidance as the type of
costs to be included in analyzing cost impacts to the states. That is, the focus is on mandated costs
associated with enforceable duties falling on states, and the EPA does not interpret state administrative
costs to be among mandated costs.

Comment 2: Commenter 17868 believes that the EPA ignored several principal tenants of EO 13132.
Specifically, the commenter references section 3(b) of EO 13132, which requires agencies to consult
with state and local officials to determine whether federal objectives can be attained by other means
where there are significant uncertainties as to whether national action is authorized or appropriate.

Response to Comment 2: Commenter implies that there is significant uncertainty about the agency's
authority to issue the final rule and whether it is appropriate to address the hazards to public health and
the environment posed by EGUs. The EPA disagrees with the commenter. The EPA determined that it
was appropriate and necessary to regulate EGUs in December 2000 and added such units to the section
112(c) list. Sources listed must be regulated pursuant to section 112(d). See section 112(c)(2).

Comment 3: Commenter 18447 does not understand why the EPA categorically states that the federal
government will not provide funds necessary to pay the imposed "substantial direct compliance costs on
state and local governments." The commenter believes the costs of complying with the rule will be
substantial and will impact ratepayers dramatically, potentially driving residents and businesses from the
city in an effort to seek cheaper electricity elsewhere. The commenter believes its city is more
disproportionately impacted by the rule than utilities with larger and more diverse generation resources.

Response to Comment 3: EO 13132 provides that when a regulation imposes substantial direct
compliance costs, the agency has the option of either providing the funds necessary to pay those direct
costs or consulting with state and local officials. It does not explicitly favor either option. With respect
to the air toxics regulation for EGUs, the EPA consulted with state and local officials. As described in
the preamble to the proposed rule, the EPA invited 10 national organizations representing state and local
elected officials to a consultation meeting that was held on October 27, 2010 (76 FR 25085, May 3,
1011). The purposes of that consultation were to provide general background on the proposal, answer

679


-------
questions and solicit input from state/local governments. As required by the EO, a FSIS was included in
the preamble to the proposed rule. An impact statement is also included in the preamble to the final rule.

In response to the commenter's concerns that their costs of complying with the rule will be substantial
and disproportionately high resulting in dramatic impacts on their ratepayers, the EPA believes that
flexible and achievable pollution control requirements are promoted through alternative standards,
alternative monitoring and compliance options, and emissions averaging as a means of demonstrating
compliance with the standards for existing EGUs. Moreover, as discussed elsewhere in this document,
the EPA's analyses indicate that the impacts of compliance with the rule will not cause a significant
increase in electricity costs to rate payers.

2. Federal and state interaction.

Comment 4: Commenters 17791 and 17701 appreciate the EPA's participation in ongoing meetings
with industry, environmental groups, state air regulators and state energy officers to provide the
opportunity to better understand how they can work together as rules such as this proposal are
implemented. The commenters note that the EPA officials have made themselves available and have
sought input on the rulemaking from their organization representing utility commissioners. The
commenter encourages continued dialog and interaction between federal and state air and energy
regulators.

Commenter 17791 points out that continued collaboration between the federal agencies, states, and
industry will be essential to further promoting energy efficiency and reducing emissions. The
commenter discusses prior state energy efficiency efforts that the EPA was involved with — the National
Action Plan on Energy Efficiency (NAPEE) and the State Energy Efficiency Action Network (SEE-
Action).

Response to Comment 4: The EPA welcomes these observations and recognizes the important
contributions of state and local governments to the rule development process. The EPA will continue to
work with state and local governments to fulfill its mission of protecting human health and the
environment.

680


-------
7F - Executive Order 13175, Consultation and Coordination with Indian Tribal Governments

Commenters: 12462, 15182, 16122, 17674, 17732, 17733, 17846, 18017, 19686

Comment 1: Several commenters (12462, 16122, 17846) support stringent EPA regulations on toxic air
emissions that must eliminate the disproportionate impact on the American Indians and Alaska Natives,
and Indigenous Peoples, their lands, waters and natural resources.

Commenter 16122 also notes that the EPA has a responsibility to not only identify but address the very
significant effects that Indian tribes and their members face from their exposure to Hg emissions from
EGUs. The commenter notes the impacts of Hg contamination pose not only disproportionally high and
adverse health effects, but unique and distinctive threat to its members because of the enormous and
cultural value natural resources have for the Tribe and its members.

Comment 2: Commenter 15182 notes concern within tribal communities that methylmercury in ogaa
(walleye) may pose a serious threat to the health of fetuses and young children as the practice of
harvesting, sharing, and consuming the fish is passed down through generations. The commenter notes
that ogaa and other fish represent a significant subsistence food source for tribal communities and that
tribes are disproportionately impacted by the Hg levels in these fish that regularly exceed the EPA fish
consumption guidance values. The commenter suggests that limitations on the consumption of ogaa and
other species as a result of elevated Hg concentrations threaten the traditional Anisinaabe lifeway and
the ability of the Chippewa people to fully exercise their treaty harvest rights.

Response to Comments 1-2: The EPA acknowledges the support for stringent federal regulations of
EGU air toxics emissions from commenters and understands the concerns expressed by commenters
with regard to tribal member exposure to Hg emissions from EGUs and elevated Hg levels in
subsistence fish. We believe that the final rule will substantially reduce the emissions of Hg in the U.S.
The resulting reduction in emissions will benefit communities with subsistence lifeways, including
Native American Indians and Alaska Natives, whose traditional diets include high consumption of fish.

Comment 3: Commenter 12462 requests that the EPA fulfill its mandate to respect the rights of tribes,
as sovereign governments, to exercise their right to self-determination with an appropriate consultation
process on regulations that affect the health, safety and welfare of Indigenous Peoples. The commenter
asserts that the federal government and the EPA must acknowledge its trust responsibility to Tribes to
end the disproportionate impact of air toxins from EGUs. The commenter also cites an example in which
the Michigan Department of Environmental Quality (MDEQ), was delegated the authority to issue a
Permit to Install (PTI) to a coal-fired power plant but did not consider the different and disproportionate
impacts on Tribes.

Comment 4: Several commenters (16122, 17733, 17846, 19868) state that the EPA has a strict duty and
legal obligation under the Trust Responsibility to promulgate a MACT standard that fully and
adequately protects its environmental interests and its tribal resources. Commenters note that it is clear
that Hg deposition from EGUs have significantly impacted culturally-important lands, waters and
natural resources on reservations.

Commenter 19686 recommends that the EPA devote more of its resources to conduct in-depth studies
regarding the effects of Hg emissions on Tribal communities, and in fact, the EPA should do such
studies for other pollutants. Further, commenter 19686 recommends that the EPA conduct a benefits
analysis that fully assesses the rule's impacts on Tribal air quality and health, as well as cultural and
subsistence practices.

681


-------
Comment 5: Commenter 18540 believes that the EPA has a trust responsibility to ensure that the
Community's water rights, and other guarantees and benefits provided in the Arizona Water Settlements
Act (AWSA) are preserved, and that the trust responsibility prohibits the agency from imposing a Utility
MACT that limits the community's ability to receive and use Central Arizona Project (CAP) water. The
commenter believes the proposed rule would force the closure of Navajo Generating Station (NGS),
inhibiting and possibly eliminating the Community's right to receive and utilize its allocation of CAP
water guaranteed by the AWSA. The commenter believes that the proposed Utility MACT rule would
make it extremely difficult, if not impossible, to pay for CAP water and would eviscerate the future
Development Fund revenue stream that is intended to subsidize CAP water costs and pay for operation,
maintenance, and replacement charges associated with the delivery of CAP water. Even more, the
proposed Utility MACT rule would limit the Community's ability to farm its reservation lands and its
future economic development opportunities, and would negatively impact the livelihood and health of
Community members.

Comment 6: Commenters 17674 and 17732 have concerns with the consultation with their tribal
governments as required by EO 13175. Commenter 17674 is troubled that the EPA has not undertaken
any formal consultation with their tribal community, despite a formal request submitted in July. The
commenter believes given the nature of the interests at stake, the implications of the proposed rule, and
the EPA's federal trust obligations, consultation must be among senior-level EPA officials and tribal
leaders. Commenter 17732 states that the EPA only provided a generic letter to the tribal government as
consultation. The commenter believes the proposed rule will have substantial direct effects on its tribal
community, which relies on two of the three coal-fired power plants identified in the Tribal Outreach
memo, and their supporting mines, for one third of its general operating fund in addition to significant
jobs provided by both the plants and their mines. Therefore the commenter believes that the EPA must
do better to engage their tribal government in meaningful consultation on this and other proposed
rulemakings.

Response to Comments 3-6: The EPA appreciates these comments and recognizes the importance of
appropriate consultation with tribes in developing this rule, consistent with the federal government's
trust responsibility to federally recognized tribes. The EPA agrees that this rule affects tribes and as
such, we actively encouraged tribes to participate in our rulemaking. We conducted outreach and
information sharing with tribal environmental staff through the monthly National Tribal Air Association
calls, at the National Tribal Forum, and a webinar targeting tribal environmental professionals on the
content of the proposal. In addition, we sent letters to all tribal leaders and offered consultation on the
rule, prior to proposal and after the proposal, to ensure tribes had the opportunity to participate in the
process. Because of concerns raised by several tribes, and in order to help us better understand their
concerns, we also participated in a face-to-face meeting with tribes in Arizona who were concerned
about the potential impact of this rule on their income and water rights. Following that meeting, we held
an additional technical meeting on how IPM is used in the RIA and provided one-on-one consultation
with the Navajo Nation, Gila River Indian Community and the Ak-Chin Indian Community. Thus, the
EPA disagrees with commenter statements that the EPA has not undertaken any formal consultation
with their tribal community. The EPA also points out that senior-level EPA officials were involved in
the meetings. The EPA would like to clarify that the generic letter to tribal governments to which one
commenter refers was not intended to be "the consultation" but, rather, it offered consultation.

With regard to commenters' concerns about the impact of the final rule on NGS and the delivery of
water under water settlements in Arizona, the EPA recognizes the significance of NGS to the Central
Arizona Project and has been consulting with affected Indian tribes and working closely with other
federal agencies, including the Department of the Interior, on these issues. The EPA does not believe

682


-------
that the agency is precluded from regulating NGS under section 112 of the CAA or that based on
available information the water settlements require exclusion or disparate treatment of the facility under
this CAA regulation. The facility is currently regulated under other CAA programs, and we believe that
the requirements of section 112 also apply. The EPA is, however, mindful of the complex situation
relating to NGS and the delivery of water in Arizona. The EPA is committed to continuing to work
closely with affected tribes and other federal agencies to consider these issues as the rule is
implemented, consistent with the federal government's trust responsibility to the tribes. The EPA also
notes that it is not currently certain what decisions will be made with respect to NGS's operation to
address the rule's requirements. The EPA's modeling and projections are intended to be a reflection of
possible compliance using specific tools, assumptions, and methodologies that the agency believes to
reflect the best and most current information related to the power sector. The inclusion of other
regulatory actions (including federal, state, and local actions) in the modeling reflects the level of
controls that are likely to be in place in response to other requirements apart from MATS and provides
meaningful projections of how the power sector will respond to the cumulative regulatory requirements
for air emissions. It is not intended to reflect actual compliance decisions, since those will be made
individually by the affected industry based on what makes most sense using existing technologies or
other, more cost-effective strategies. For that reason, we caution commenters not to assume that any
statements in EPA's modeling analyses about possible actions by NGS, including closure, reflect the
only possible outcome of the final rule. The EPA will work with relevant authorities to ensure a smooth
transition with this rule and address specific issues as they arise. Public utility commissions and other
authorities, including tribes, will need to develop and implement compliance plans in order to address
harmful emissions.

With regard to one commenter's concerns about the permits issued by the MDEQ, we note that the
agency under its environmental justice (EJ) strategy known as Plan EJ 2014 is actively pursuing tools,
resources and guidance to improve the incorporation of EJ considerations in our permitting. However,
this rule will not affect the preconstruction permitting New Source Review programs, and this issue
cannot be addressed by this rulemaking.

In response to one commenter's recommendation that additional studies and analyses be conducted, we
agree that additional analysis would be helpful to better understand the impacts of air pollution,
particularly Hg, on Native American populations. This rule addresses impacts of air pollution on Native
American populations in that it regulates Hg air pollution from EGUs. The EPA's Office of Research
and Development has undergone realignment to better address agency priorities, for which
disproportionate exposure is of particular concern. This issue falls within the content areas of the
Sustainable and Healthy Communities, Air, Climate and Energy, and Safe and Sustainable Water
Resources research programs, which are working in a more integrated way with sustainable human and
ecological well-being as the goal. Air pollution contamination of food fish falls within their work on
multipollutant emissions, transport and cascading effects. This comment will be provided to those
groups to ensure that these issues of critical importance to Tribal communities are given due
consideration in research efforts.

Comment 7: Commenter 17732 generally supports the proposed NESHAP Rule in its goal of
addressing reductions of HAP from stationary sources. The health and well-being of the natural
environment and the people of the tribal nation are of utmost importance to the commenter. As a tribal
nation and small government landlord of affected EGUs, the commenter states that the EPA is obligated
to consult with the tribal nation and analyze the economic impacts to the nation in promulgating the
proposed rule. The commenter further states that the EPA is required to tailor the proposed rule so that
the costs of compliance for plants located on the tribal nation are achievable within a reasonable

683


-------
timeframe, while taking into account the unique challenges of the plants for this and future rulemakings.
The commenter explains that compliance costs to meet BART have the potential to impact the tribal
nation economy significantly. The commenter is concerned that the rule will create a recurring threat of
severe reductions in the revenue received from the power plants and their supplying mines. The
commenter asks that the EPA analyze the impacts from these rulemakings and provide flexibility for
compliance scheduling so that EGUs upon which the Nation relies can continue operations.

Response to Comment 7: The EPA recognizes the concerns raised by the commenter as a tribal nation
and small government landlord of EGUs, although landlords of affected facilities are not included in the
definition of an affected small entity. The EPA estimated the potential impacts associated with
complying with the rule on all entities that own affected EGUs, including those located on tribal nation
land. We offered consultation to all tribal governments and conducted one-on-one consultation with the
commenter. With respect to the compliance schedule, the EPA has provided the maximum 3-year period
for sources to come into compliance as allowed by section 112 of the CAA. Sources may also seek a 1-
year extension of the compliance period from their Title V permitting authority if the source needs that
time to install controls. CAA section 112(i)(3)(B).

Comment 8: Commenter 17674 expresses concern with the EPA's presumption in the rulemaking that
the NGS will close in 2015, citing the RIA where the EPA presumes that two of the three units would
retire with or without implementation of the Utility MACT and the third would be forced to retire as a
result of the economic and regulatory burdens imposed by the proposed rule. The commenter believes
these assumptions are in contrast to prior statements by the EPA regarding the facility during the BART
rulemaking. The commenter also believes the EPA must address the catastrophic impacts that the Utility
MACT will have on Arizona tribes and reconcile these opposed positions.

Response to Comment 8: As mentioned previously, the EPA conducted extensive outreach and
consultation on this rule. However, because of concerns raised by several tribes, and in order to help us
better understand their concerns, we also participated in a face-to-face meeting with tribes in Arizona
who were concerned about the potential impact of this rule on their income and water rights. Following
that meeting, we held an additional technical meeting on how IPM is used in the RIA and provided one-
on-one consultation with the Navajo Nation, Gila River Indian Community and the Ak-Chin Indian
Community. We point out that IPM is used to analyze the power sector's cost-minimizing response to
meet electricity demand with MATS in place. The EPA modeling and projections are intended to be a
reflection of possible compliance using specific tools, assumptions, and methodologies that the agency
believes reflect the best and most current information related to the power sector. It is not intended to
reflect actual compliance decisions, since those will be made individually by the affected industry based
on what makes most sense using existing technologies or other, more cost-effective strategies. Thus the
EPA's IPM analysis of MATS does not dictate what a given facility must do to comply with MATS.
Each facility may determine its own compliance strategy to meet the emission rate limits in MATS. The
EPA will work with relevant authorities to ensure a smooth transition with this rule and address specific
issues as they arise. Public utility commissions and other authorities, such as tribes, will need to develop
and implement compliance plans in order to address harmful emissions. We would point out that
changes in the final rule are significant and will reduce costs, increase flexibility and alleviate industry
concerns about achievability of standards.

Comment 9: Commenter 17674 discusses numerous considerations regarding NGS, suggesting it
should be treated differently from other generating units because it is a unique facility with a significant
federal purpose. The commenter notes that NGS powers the delivery of water, a trust resource, to fulfill

684


-------
the mandate of eight Congressionally-approved Indian water rights settlements, to Native American
communities, and provides jobs both directly and through the associated coal mine.

Response to Comment 9: As discussed above, the EPA is sensitive to the commenters' concerns and
intends to work with tribal and other authorities to ensure a smooth transition and address specific issues
as they arise. However, we note that section 112 of the CAA imposes specific requirements with respect
to the methodology the EPA must use in establishing emission standards for HAP, including Hg
emissions from EGUs. The commenter suggests treating NGS differently from other generating
facilities, and we interpret this comment at least in part as a request for a subcategory for NGS. Pursuant
to CAA section 112(d)(1), the EPA may subcategorize sources based on differences in class, type, or
size. In the preamble to the proposed rule, the EPA further explains that any basis for subcategorizing
(e.g. class) must be related to an effect on emissions, rather than some difference which does not affect
emissions performance. The EPA does not agree that a subcategory based on location on tribal lands is
consistent with the statutory authority to subcategorize, and the commenter does not explain why
emissions would be different for EGUs located on tribal lands. Absent that showing, it would not be
appropriate to subcategorize units even if we believed such a subcategory was consistent with the
statute. Another commenter believes that there is no legal or factual basis for creating subcategories or
weaker standards for state, tribal, or municipal governments or small entities that are operating obsolete
units. The commenter points out that relaxation in standards would not only harm downwind
governments and small businesses who incur higher labor costs due to pollution, but will harm other
small businesses and state, tribal and local governments developing or operating generation facilities
using modern and less polluting generation technologies. The methodology for determining emission
standards under CAA section 112 does not result in requirements that specify the means of complying
with standards. Thus, affected sources make their own determination regarding how they will comply
with the standards. We believe that flexible and achievable pollution control requirements are promoted
in the final rule through inclusion of alternative standards, alternative compliance options, and emissions
averaging as a means of demonstrating compliance with the standards for existing EGUs.

Comment 10: Commenter 18017 states that if the proposed rule and other pending rules require
installation of new control equipment costing hundreds of millions of dollars, the potential result could
be early closure of their plant because the owners will be required to comply before they know whether
the approvals necessary to operate after 2019 can be obtained. The commenter is concerned that the
EPA may establish final emission limits governing NGS PM emissions that are so stringent that a new
PM control will be required with compliance dates before approvals can realistically be obtained. The
commenter asserts that this would lead to high compliance costs and could jeopardize continued
operation of the NGS facility with severe economic impacts on numerous Indian Tribes.

Response to Comment 10: As the EPA has noted previously in this document, facilities that have or are
already in the process of installing significant emission controls are likely to experience lower
compliance costs as the result of this rule. Many coal facilities have already invested in pollution
controls, and they are well positioned to comply with this rule with modest changes to operations. The
EPA will work with relevant authorities to ensure a smooth transition with this rule and address specific
issues as they arise.

Comment 11: Commenter 19686 states that the EPA needs to integrate the United Nations Declaration
on the Rights of Indigenous Peoples (signed in December 2010) into the rule and other EPA actions. A
number of federal entities including the Department of the Interior and Department of Justice are taking
actions to implement the Declaration in their programs and policies. However, the EPA has been silent
on how it plans to implement the Declaration. The rule is a good place for the EPA to start, making sure

685


-------
that the individual and collective rights of Tribes are protected and advanced in the EPA's efforts to
reduce Hg and other toxic emissions from EGUs. The NTAA asks that the EPA inform our Tribal
members about how it plans to implement the Declaration through the rule and other EPA actions with
potential Tribal implications.

Response to Comment 11: The U.S. announced its support for the United Nations Declaration on the
Rights of Indigenous Peoples in December of 2010. US agencies, including EPA, are currently engaged
in many initiatives to address the issues in the Declaration. Consistent with the Declaration's call to
develop a concept of self-determination specific to indigenous peoples, EPA has worked to strengthen
the government-to-government relationship with tribes through the development and implementation of
its May 4, 2011 Policy on Consultation and Coordination with Indian Tribes. Consistent with the
important provisions of the Declaration that address environmental issues, in the development of this
rule EPA encouraged tribal participation, by requesting data and information from the tribes to help us
understand the impacts of the pollutant from the power plants in Native American Communities.
Additionally, EPA conducted a series of outreach and consultation activities including consultation prior
to proposal and post proposal, webinars, and onsite consultation with several tribes at their request. The
EPA's discussion of EO 13175 includes additional details regarding EPA's consultation and
coordination with Indian tribes.

Comment 12: Commenters 17846 and 19686 state that the Tribe and its members are greatly concerned
about the environmental, health, and economic impacts of Hg deposition from coal-fired EGUs. Because
of this, commenter 17846 commends the EPA for proposing a rule that, in accordance with the
requirements of CAA section 112, applies the same emission limits to all EGUs within a subcategory.
This is critical to avoid the creation of Hg "hot spots," which could leave large portions of Indian
country susceptible to continuing Hg contamination.

Response to Comment 12: The EPA acknowledges commenters' concerns and appreciates their
support of this important rule that will reduce emissions of Hg and other air toxics.

Comment 13: Commenter 19686 states that the EPA has failed to provide Tribes with any assurances
that their communities and land will not be part of Hg emission hotspots as a result of the rule's
implementation. The EPA has a trust responsibility to Tribes that requires it to look out for the general
welfare of such Tribes when taking actions with potential Tribal implications. The commenter
recommends that the EPA develop a plan for dealing with hotspots that affect Tribes. In addition, the
EPA must provide Tribes with a map overlay of Tribal lands and EGUs so that Tribes can have a better
understanding of how the rule might impact them.

Response to Comment 13: In the final rule, the EPA established technology-based standards consistent
with the requirements of CAA section 112(d). Such standards require all sources within a source
category or subcategory to reduce HAP emissions to the same level without consideration of risk. To
determine whether additional standards are necessary, the EPA will consider whether risk remains from
HAP emissions from a source category within 8 years of promulgating final section 112(d) standards
pursuant to section 112(f)(2). We encourage the commenter's suggestions on how to continue to
minimize the potential local impact of Hg from these sources as the rule is implemented. The EPA will
provide any non-privileged available information relevant to Hg deposition in Indian country in
response to a request from the tribe. Finally, we encourage tribes to work with the EPA as it considers
the risk to public health, including tribal members, in determining the need for further standards as the
EPA reviews these standards consistent with the statute.

686


-------
Comment 14: Commenter 17846 states that the Tribe and its members are greatly concerned about the
environmental, health, and economic impacts of Hg deposition from coal-fired EGUs. Because of this,
The Fond du Lac Band of Lake Superior Chippewa commends the EPA for proposing a rule that, in
accordance with the requirements of section 112, applies the same emission limits to all EGUs within a
subcategory. This is critical to avoid the creation of Hg "hot spots," which could leave large portions of
Indian country susceptible to continuing mercury contamination.

Response to Comment 14: The EPA shares the tribes concerns about Hg and its potential impact on
tribes. We believe this rule will prevent local hotspots from occurring.

687


-------
7G - Executive Order 13045, Protection of Children From Environmental Health Risks and Safety
Risks

Commenters: 10822, 12462, 16121

Comment 1: Commenter 10822 provides a copy of a journal article entitled "Pregnancy Loss and
Maternal Methemoglobin Levels: An Indirect Explanation of the Association of Environmental Toxics
and Their Adverse Effects on the Mother and the Fetus." According to the abstract, the aim of this
epidemiologic study was to point out a relationship between the exposure to products of coal
combustion, and complications in pregnancy where one third of causes of stillbirth are still unknown.

Comment 2: Commenter 12462 notes Hg is of special concern to Tribal children and women of
childbearing age, as Hg is a neurotoxin that causes neurological delays and damage. The commenter
states in utero exposure to Hg, via contaminated fish eaten by expectant mothers, can impair thinking,
memory, attention, language, and fine motor and spatial skills. Additionally, the commenter states that
children who eat Hg-contaminated fish are at risk for decreased brain function.

Comment 3: Commenter 16121 supports the EPA for its proposal to reduce Hg and other harmful
emissions, stating the American public, especially vulnerable populations such as pregnant women and
children, is currently not adequately protected from Hg exposure in the environment. The commenter
briefly summarizes Hg issues related to health effects and exposures for these populations.

Response to Comments 1-3: The EPA acknowledges the concerns of all three commenters and
appreciates their input regarding health effects of Hg and other coal combustion emissions. In addition,
the EPA thanks commenter 16121 for their general support of the proposal.

688


-------
7H - Executive Order 13211, Actions Concerning Regulations That Significantly Affect Energy
Supply, Distribution or Use

Commenters: 18447

Comment 1: Commenter 18447 suggests that, despite the EPA's conclusion, the rule is likely to have
adverse effect on the supply, distribution, or use of energy, and the EPA downplays the impact of the
rule with respect to the costs that the taxpayers and U.S economy must bear, which the commenter
believes are substantial.

Response to Comment 1: As discussed extensively elsewhere in this document, the preamble to the
final rule, the RIA, and other supporting materials, the EPA disagrees with commenter and maintains
that the EPA's analysis of the rule is reasonable, and does not understate impacts as the commenter
suggests.

689


-------
71 - National Technology Transfer and Advancement Act

No comments were received specifically on the National Technology Transfer and Advancement Act
(NTTAA) or its requirements. To the extent that the NTTAA is referenced in the context of comments
regarding another topic it has been addressed as appropriate.

690


-------
7J - Executive Order 12898, Federal Actions to Address Environmental Justice in Minority
Populations and Low-Income Populations

Commenters: 17254, 17681, 17697, 17710, 17713, 17766, 18433, 18934, 19145, 19210,
19536/19537/19538

1. General comments regarding impacts on minority and low-income populations.

Comment 1: Commenter 17254 presents a map showing the close correlation between the location of
populations below the poverty line expected in 2016 and the locations of power plants. The commenter
states that while the EPA developed these maps to show the potential impacts from fish consumption in
nearby waterways, the evidence also shows that these populations face higher risks because of the air
they breathe.

Commenter 17254 notes that coal-fired power plants are disproportionately located in or near low
income and minority communities. The commenter states that 68% of all African Americans in the U.S.
live within 30 miles of a power plant, as opposed to 56% of whites. The commenter also notes that even
though African Americans compromise 13% of the U.S. population, they account for 17% of the
population living within 5 miles of power plant waste sites.

Comment 2: Multiple commenters (17524, 19210, 19536, 19537, 19538) note that disadvantaged
communities that rely on the extra source of protein from fishing shoulder a disproportionate share of
the impact from Hg pollution. Commenter 17524 cites a study that Sierra Club commissioned from
Bendixen and Amandi, a polling firm, in which increased risks to the Hispanic community are identified
from fishing in urban communities, where fish caught tend to have the highest concentration of Hg
contamination. The commenter notes that the study reports that Hispanics in California consume almost
twice the EPA safe limit of Hg due to subsistence fishing.

Response to Comments 1-2: The EPA agrees that minority and low-income populations are
overrepresented among those persons who live in close proximity to coal-fired power plants and that
certain low income and minority community members (such as subsistence fishers) consume higher
levels of fish that may be contaminated by Hg. For these reasons, the EPA expects that minority, low-
income and indigenous population groups would benefit disproportionately from the reduced emissions
that will result from the rulemaking, both in terms of reduced inhalation of pollutants and reduced
ingestion of Hg-contaminated fish.

Comment 3: Commenterl7681 requests that the EPA work towards developing scientific evidence of
EGU's impact on Hg blood concentrations in at risk populations, such as minorities and the elderly. The
commenter notes that they are cautious to endorse a rule which will financially impact such populations
to great extent while at the same time it is witnessing unexplained substantial reductions in blood Hg
concentrations of all population classes according to the EPA's National Health and Nutrition
Examination Survey (NHANES) data.

Response to Comment 3: First, the EPA has developed an analytical method to estimate the impact of
Hg emissions from U.S. EGUs on Hg fish tissue concentrations and the implications for human health,
as documented in the National-Scale Mercury Risk Assessment. Second, the EPA disagrees that there is
a statistically discernible downward trend in the NHANES data on blood Hg. The EPA is unaware that a
formal statistical analysis for temporal trends has been completed for NHANES data on blood Hg levels
for the period 1999 to 2008. Mahaffey et al. 2009, evaluating NHANES data collected 1999 to 2004 for

691


-------
women at child-bearing age, could "not support the conclusion that there was a general downward trend
in blood mercury concentrations over the 6-year study period." However, the same publication noted
that "there was a decline in the upper percentiles reflecting the most highly exposure women" having
blood Hg concentration greater than established levels of concern. Visual observations of the data show
a slight decrease in Hg blood level concentrations from 1999-2008 at the geometric mean. This decrease
may not be statistically significant based on overlapping confidence intervals. A decrease in Hg blood
level concentrations is also observed at the 95th percentile. Except for differences observed between
1999 and 2008, the temporal decrease may not be statistically significant. Conclusions cannot be drawn
without further and more formal statistical analysis of the data.

The EPA remains concerned that substantial numbers of women of childbearing age in the U.S. may
have blood Hg levels that are equivalent to exposures at or above the RfD. Mean and 95th percentiles
from recent NHANES data are below 5.8 ug/1 (a blood Hgy concentration equivalent to the RfD).
However, blood levels for some portions of the population (high consumers of fish, for example) may be
indicative of exposures above the RfD. The EPA did not find data for NHANES blood distributions
above the 95th percentile. Modeled data from Tran et al., 2004 provided estimates showing high blood
Hg levels at the 99th percentile for females of child-bearing age (i.e., 24.41 ug/L at the 99th percentile).
Mahaffey et al. 2009 showed that 2.4% of women of child-bearing age had blood Hg values above 5.8
ug/L. Other published studies have shown that various population groups can have high blood Hg levels
(Mahaffey 2005; Miranda et al. 2011; Hightower and More 2003; Hightower et al. 2006; McKelvey et
al. 2007). For example, in Hightower et al. 2006, the authors found that Asian populations had Hg
exposures greater than 5.8 ug/L in 83% of the Asian population compared to 12% for the total survey
population.) (Butler Walker, J., J. Houseman, et al. (2006). "Maternal and umbilical cord blood levels of
mercury, lead, cadmium, and essential trace elements in Arctic Canada." Environ Res 100(3): 295-318;
Hightower, J. M. and D. Moore (2003). "Mercury levels in high-end consumers of fish." Environ Health
Perspect 111(4): 604-608; Hightower, J. M., A. O'Hare, et al. (2006). "Blood mercury reporting in
NHANES: identifying Asian, Pacific Islander, Native American, and multiracial groups." Environ
Health Perspect 114(2): 173-175.)

Comment 4: Several commenters (17697, 17710, 18433) note that Guam is designated as a "distressed
nonmetropolitan middle-income" area due to both high poverty and unemployment rates, yet its utility
costs are among the highest in the nation. Given these circumstances, commenter 17710 requests that the
EPA consider relief for the Guam Power Authority (GPA) from the final rule.

Commenter 17710 suggests the compliance costs and risks associated with the rule would require
significantly increased electricity rates that could cause economic hardship on its customers, such as the
unemployed, underemployed and those with limited or fixed incomes.

Response to Comment 4: The EPA disagrees that the rule will result in significantly increased prices
for electricity. The increase in electric rates to consumers as shown in the RIA will be 3.7% on average
nationally by 2015. These increases are accompanied by substantial benefits to health from the emission
reductions that will take place across the country due to this rule. The increased price information is
factored into the agency's decision making and is discussed in more detail in the RIA. States and local
entities responsible for utility rate structures are best positioned to deal with economic impacts on low
income customers and with the overall distribution of increased costs.

The EPA expects that the general population, including low income persons, would experience
significant health benefits as a result of this rulemaking. The standards would prevent as many as 17,000
premature deaths and 11,000 heart attacks a year and would provide particular health benefits for

692


-------
children, preventing 120,000 cases of childhood asthma symptoms and about 11,000 fewer cases of
acute bronchitis among children each year. The EPA estimates that for every dollar spent to reduce
pollution from power plants, the American public and American businesses will see up to $13 in health
and economic benefits. It is also likely that household income for some low income families may
increase if individuals are able to work (or work more) as a result of improved health.

Finally, the EPA has acknowledged the unique circumstances of non-continental liquid oil-fired EGUs,
such as those on Guam, and adopted specific provisions for them in the final rule.

Comment 5: Commenter 18934 suggests that in the case of EJ communities, more extensive reductions
beyond that required to meet the average level achieved by the top 12% of plants be required as such
technology exists. The commenter offers to work with the EPA to further define EJ communities for
such a purpose.

Response to Comment 5: CAA section 112(d) standards are technology-based standards. Pursuant to
section 112(d)(3), the EPA establishes MACT floor limits for existing sources based on the best
performing 12% of sources. After establishing the MACT floors, the statute requires the agency to
determine whether standards more stringent than the MACT floor are achievable after considering the
costs of achieving such additional emission reductions and the non-air quality health and environmental
impacts of more stringent standards. CAA section 112(d)(2). The EPA has conducted an analysis
consistent with section 112(d)(2) for this rule and determined that a more stringent standard is
achievable for one pollutant from one existing source subcategory. As the D.C. Circuit recognized in
Sierra Club v. EPA, 353F.3d976 (D.C. Cir. 2004:

"These [112(d)(2) and (d)(3)] emission standards are to be based not on an assessment of the risks posed
by HAP, but instead on the maximum achievable control technology (MACT) for sources in each
category. Senate Report, at 148 ("The MACT standards are based on the performance of technology,
and not on the health and environmental effects of hazardous air pollutants."). The standards, at a
minimum, must reflect the emissions limitation achieved by the best-performing sources in a particular
category. . . The idea is to set limits that, as an initial matter, require all sources in a category to at least
clean up their emissions to the level that their best performing peers have shown can be achieved." 353
F.3d at 990.

In Sierra Club, Sierra Club argued that the phrase "non-air quality health and environmental impacts" in
112(d)(2) required the EPA to consider the "impacts of deposition, persistence, toxicity and
bioaccumulation of metal HAP emissions on people, wildlife and the environment." The Court rejected
this argument and upheld the EPA's interpretation of the phrase, which was that "'non-air quality ...
impacts' refers to any health and environmental impacts ... that may result directly or indirectly from
[the control] measures that will achieve the emission reductions." 353 F.3d at 990-91. The Court further
held that "Sierra Club's interpretation would collapse the technology-based/risk-based distinction at the
heart of the Act, undermining the central purpose of the 1990 Amendments." Id. The commenter here
seeks to infuse risk into setting technology-standards, which is not permissible.

Within 8 years after the EPA promulgates section 112(d) standards, section 112(f) directs the agency to
evaluate the risk remaining after implementation of the MACT standards to determine whether the
standard provides an ample margin of safety to protect public health. The EPA will consider risks posed
to disadvantaged communities in that evaluation, but any resulting standards must be national in their
scope and applicability. To the extent that any given community is seeking greater protection than a

693


-------
national rule would provide, we encourage them to work with the appropriate State and local authorities
to fashion solutions that are specific to their community.

Comment 6: Commenter 19145 provides several statistics on the disproportionate impacts related to
African Americans and power plants. The commenter uses these statistics to show pollution from power
plants is an issue of racial disparity as African Americans are most likely to be exposed to the toxins
coming from power plants and the impact is apparent through the higher rates of infant mortality, low
birth weight, and premature births among the population. The commenter also notes that the African
American population has increased rates of asthma, with power plant pollution being a contributing
factor to asthma and chronic bronchitis.

Response to Comment 6: The EPA agrees that minority populations, including African Americans,
generally have worse health than whites and that many minority and low income communities are
overburdened by air pollution. The EPA agrees that the African American population has increased rates
of asthma compared to other population groups and that pollution from power plants can be a
contributing factor to asthma and chronic bronchitis. To that extent, African Americans living in the
vicinity of power plants can be expected to receive disproportionate benefits from the rule's
implementation.

Comment 7: Several commenters (19536, 19537, 19538) believes information gathering and better
understanding of the cumulative health impacts in areas where many sources of HAP are located
together, such as industrial areas, would be beneficial for addressing EJ concerns.

Response to Comment 7: The EPA generally agrees with the value of assessing cumulative impacts in
such areas, and that additional data would be useful in that process, but collection of these data is outside
the scope of this regulatory action.

2. The EPA did not meet requirements of EO 12898.

Comment 8: Commenter 17713 believes the Environmental Justice Statement included in the proposed
rule does not meet the requirements of EO 12898 as it failed to address increased electric rates to
consumers that will cause disproportionate harm to minority, fixed-income and low-income populations,
as well as health impacts from the decreased disposable incomes that these consumers would have to
spend on health care, food, cooling and heating, and housing.

Response to Comment 8: The EPA does not agree with the commenter's assertion that the agency
failed to consider the impacts of increased electric rates to consumers, including minority, fixed income
and low-income populations. The commenter also makes an assertion which relies on a theory that the
cost of a rule will result in lost income that will, in turn, result in negative health effects that offset the
positive health effects of the rule. (This is sometimes referred to as a "health-health tradeoff") The EPA
also disagrees with this claim and notes that there are a number of conceptual and empirical problems
with any attempt to quantify the health-health tradeoffs of regulatory action to control air pollution.
Claims about health-health tradeoffs rely on questionable applications of cross-sectional data and ignore
key factors that may influence changes in population health risks. Additionally, marginal decreases in
household income caused by the pass-through costs of the regulation are unlikely to cause large changes
in any single aspect of household spending, such as health care. These analyses also fail to consider that
household income may increase if individuals are able to work (or work more) as a result of improved
health, offsetting some or all of the pass-through costs of the rule. For these and other reasons, the

694


-------
EPA's science and economic peer review panels have consistently advised against incorporating alleged
health-health tradeoffs in the EPA analyses of regulatory effects.

The agency's rule requires reductions of HAP such as Hg, arsenic, lead and other metals, that are shown
to cause serious injury to exposed populations. The benefits of Hg and HAP emission reductions, along
with the substantial benefits from reductions in emissions of PM, SO2, and other pollutants are shown in
our RIA. Populations that are the focus of EO 12898 will benefit from these reductions as shown in the
RIA. In addition, the increase in electric rates to consumers as shown in the RIA will be 3.7% on
average nationally by 2015, with some consumers in certain regions seeing increases of less than 10%
while other consumers in different regions will see increases of only 1%. These increases in electric
rates may not be minimal in some areas of the U.S., but they should be seen in light of the substantial
benefits to health from the emission reductions that will take place across the country due to this rule.

Comment 9: Commenter 17713 believes the Environmental Justice Statement failed to consider the
cumulative impacts of the rule in addition to other power sector rules, which disproportionately impact
lower income, elderly and minority populations. The commenter cites an economic analysis prepared by
National Economic Research Associates for the American Coalition for Clean Coal Electricity (ACEE)
showing estimated increases in electricity prices, natural gas prices, and loss of jobs from the combined
impacts of the proposed rule and the CSAPR. The commenter also includes in their comment a copy of a
January 2011 publication entitled "Energy Cost Impacts on American Families, 2001-2011" and cites a
March 2010 study performed for the Affordable Power Alliance by Management Systems, Inc. on the
effect of GHG regulations, both of which conclude that there are disproportionate impacts on low
income and minority groups from these regulations.

Response to Comment 9: As discussed above, the EPA disagrees with the assertion that the rule will
result in disproportionate negative impacts on low-income, elderly, and minority populations. The EPA
believes this rule will provide significant benefits to all citizens, including minority, low-income and
indigenous populations. Furthermore, the EPA has recently assessed the cumulative impact of
regulations adopted to implement the 1990 CAA Amendments. In March 2011, the EPA issued the
Second Clean Air Act Prospective Report which assessed the benefits and costs of regulations pursuant
to the 1990 CAA Amendments. The study examines the cumulative impact of these regulations (found
at http://www.epa.gov/air/sect812/febll/summaryreport.pdf). As shown in the report, the direct benefits
from the 1990 CAA Amendments reach almost $2 trillion for the year 2020, a figure that dwarfs the
direct costs of implementation ($65 billion). The full report is at

http://www.epa. gov/air/sect812/prospective2.html. The direct benefits of the 1990 CAA Amendments
and associated programs significantly exceed their direct costs, which means economic welfare and
quality of life for Americans were improved by passage of the 1990 Amendments. The wide margin by
which benefits exceed costs combined with extensive uncertainty analysis suggest it is very unlikely this
result would be reversed using any reasonable alternative assumptions or methods. The EPA believes
the same conclusion applies to this rulemaking, as discussed in the RIA.

The economy as a whole is also stronger with 1990 CAA Amendment programs as cleaner air leads to
better health and productivity for American workers and less money spent on health care to treat air
pollution-related health problems. Economy-wide modeling shows that long-term economic growth is
greater and American household economic welfare is improved because benefits such as fewer sick days
and lower medical costs more than offset the economy-wide cost of investing in air pollution control.

695


-------
Comment 10: Commenter 17713 suggests that high energy prices from the rule will lead to businesses
cutting costs by laying off workers, with low-wage workers being the groups that will be impacted by
such layoffs. The commenter notes that low-wage workers are disproportionately Black and Hispanic.

Response to Comment 10: As discussed elsewhere in this document, the EPA's analysis shows that
high energy prices will not result from this rule, and increases are expected to be 3.7% on average
nationally by 2015. The EPA estimates that the overall impact on short-term employment will be an
increase on net of 46,000 jobs associated with the rule, with an increase in long-term jobs annually of
9,000 (with jobs being measured as job-years, or 1 year of employment for one full-time worker). The
range of employment impacts in the long-term is a loss of 15,000 to a gain of 30,000 jobs. Thus, any
lay-offs will be smaller than the number of jobs expected to be supported or created from compliance
with the rule.

Comment 11: Commenter 17713 believes the EPA's regulations will significantly impact the cost of all
fossil fuels, leading to an increase in prices of all basic goods, disproportionately impacting minority
populations. The commenter provides statistics showing the percentage of income spent on food,
housing and clothing by minority populations in comparison to Whites.

Response to Comment 11: Although there may be increases in price for electricity, natural gas, and
coal associated with this rule, it should be noted that the increase in electricity price to consumers is less
than 4% by 2015, and the increase in natural gas price on average from 2015-2030 is less than
1.5%. These estimates are presented in the RIA for the rule. Thus, these increases are unlikely to
significantly affect the prices of basic goods, and are modest when considering the substantial benefits
from reductions of HAP and other pollutant reductions that this rule is expected to achieve. These
benefits will be enjoyed by minority populations, as well as other populations, and to a disproportionate
extent for those living in the vicinity of power plants.

Comment 12: Commenter 17713 notes that the combined impacts from increased unemployment,
reduced incomes, and increased prices for housing, basic necessities, energy, and utilities resulting from
the EPA regulations will further reduce Black and Hispanic discretionary incomes.

Response to Comment 12: As discussed elsewhere in this document and the preamble to this rule, the
EPA provides estimates of the impact of this rule on energy prices, unemployment, and prices for
industries affected by any predicted increases in energy prices in the RIA for this rule. As stated above,
the EPA expects that the impacts of increased electricity prices would be small and would be more than
offset by increases in employment and the substantial benefits from reductions of HAP and other
pollutant reductions that this rule is expected to achieve.

3. The EPA met requirements of EO 12898.

Comment 13: Commenter 17766 believes the current rule as written, would significantly protect
minority and low-income populations living near coal- and oil-burning EGUs by lowering Hg, HAP, and
fine particulate emissions in the air and in turn Hg in water and accumulated in fish.

Response to Comment 13: The EPA agrees with this comment.

696


-------
7K - Statutory and Executive Orders: Other

Commenters: 15182, 16705, 17295, 17400, 17697, 17710, 17824, 18038, 18433, 18433, 18575, 19042,
19213, 19580

Comment 1: Commenter 15182 requests that the EPA further regulate emissions from power plants to
meet the goal of achieving zero emissions of nine critical pollutants (including Hg) by 2020, which the
EPA and other signatories established under the Binational Program to Restore and Protect Lake
Superior.

Response to Comment 1: Reductions in Hg and other emissions from this action are modeled for full
compliance in 2016. Although this action is neither intended nor required by the CAA to achieve the
zero emissions target of the Binational Program to Restore and Protect Lake Superior, it is a critical step
toward significantly reducing overall emissions of these pollutants in support of that goal by the
year 2020.

Comment 2: Commenter 17751 believes the proposed rule does not adequately comply with EO 13563,
EO 12866, the RFA or UMRA. The commenter also believes the proposal does not show the proposed
emissions reductions would have substantial benefit, ignores the "dwarfing" presence of Hg from natural
sources, and attempts to justify the rule almost completely from alleged co-benefits. The commenter also
notes that the proposal does not fully consider that state of scientific knowledge, is duplicative of other
regulatory programs, violates the requirements of the Information Quality Act (IQA), and fails to carry
out the requirements of UMRA and EO's to compare costs and benefits of alternative regulatory
approaches, including no regulation.

Response to Comment 2: The EPA has complied with all applicable statutory and executive order
requirements in the preparation of this rulemaking. The RIA for the proposed rule does show that the
emission reductions from this rule would result in substantial benefits (on the order of $50 to over $100
billion). Accounting for ancillary benefits is standard practice in benefit-cost assessment since these
benefits are a consequence of the rule, regardless of the rule's intended purpose. As such, the EPA
estimates all of the anticipated costs and benefits associated with a regulatory action, to the extent
feasible, for the purpose of determining the likely impacts, not to justify an action. This rule is expected
to achieve substantial PM2.5 health benefits resulting from primary PM and SO2 emission reductions and
are, thus, an important category to quantify. Consideration of ancillary benefits in benefit-cost analysis
is directed by OMB Circular A-4.

Comment 3: Multiple commenters (16705, 17295, 17400, 17697, 17710, 18038, 18433, 18575, 19213)
request that the EPA evaluate the impact to their utility under the SBREFA, UMRA, EO 13563, EO
13132, EO 12866 and EO 13211 based on their concerns with the proposed rule. The commenters state
that they have standing under these Executive Orders to call for reasonable and cost-effective
regulations to achieve reductions in air pollution in a reasonable timeframe.

Response to Comment 3: The EPA has complied with all applicable statutory and executive order
requirements in the preparation of this rulemaking. All utilities that the agency expects will be impacted
by this rule have been included in all analyses completed as part of compliance with the applicable
statutory and executive order requirements. The results of these analyses are contained in the RIA for
this rule, in various TSD) prepared for this rule, and the results are summarized in the preamble for this
rule. Results of these analyses are available in various level of detail in the RIA and the TSDs, and the
detailed results can be found in the docket for this rulemaking and through the official web site for this

697


-------
rule. In adopting a final rule establishing national emission standards, the EPA is not required to conduct
individual plant-specific analyses under the cited statutes and executive orders.

Comment 4: Commenter 18575 requests that the EPA review the impacts of the proposed rule on a
"least cost to society basis," pursuant to EO 13563, 12866, 13211, and 13132, as the commenter
believes the EPA can propose less costly, yet still protective, alternatives to the proposed rule.

Comment 5: Commenter 19580 recommends the EPA more closely follow the existing requirements
for promulgating regulations and actually conduct detailed analysis prior to rulemaking. This analysis
would include: a review of the EPA's IQA Guidelines; a detailed RFA analysis to determine the impact
of a regulatory action upon small businesses before certifying that there is no significant economic
impact; UMRA analysis to determine the least costly, most cost-effective, or least burdensome
alternative that achieves the objective of the rule; and PRA analysis to determine if OMB approval is
needed to meet information collection requirements.

Response to Comments 4-5: The EPA is obligated to meet the relevant requirements of the CAA. In
doing so, the agency developed control strategies in the proposal that would show how affected EGUs
could meet these requirements at least cost to them consistent with the requirements of the rule. In
addition, the agency is mindful of mitigating the cost to society as part of this regulatory effort and
completed economic impact analyses for this rule that examined the impacts not only to the electric
power sector but to sectors outside of the power sector. These analyses are in the RIA for the rule. The
agency also completed analyses and consultations in compliance with the stated Executive Orders; the
OMB and other federal agencies reviewed these analyses and was aware of the consultations. All of the
analyses are in the RIA and in other documents within the docket for this rulemaking; documentation for
the consultations are in the docket as well.

Comment 6: Commenter 19042 suggests the Obama Administration has, with limited transparency and
no Congressional and industry scrutiny, promulgated a complex scheme of Executive Orders, reports,
scorecards, and associated documents that assert implementation of various environmental regulations
will reduce costs to the federal government and industry without any supporting analytical regulatory
documentation. The commenter notes several sustainability goals identified by EO 13514 and imposed
by the CEQ, noting that as a result of the proposed Utility MACT standards, utility costs will increase
within the federal budget, obviating any potential savings claimed by the Obama Administration due to
implementation ofEO 13514.

Response to Comment 6: In adopting today's final rule, the EPA has complied with the statutes and all
relevant executive orders, and has provided extensive documentation in support of its technical and
economic analyses. To the extent that the commenter is questioning other actions taken by the Executive
Branch, this comment is outside the scope of this rulemaking.

Comment 7: Several commenters (19536, 19537, 19538) maintains that because endangered, threatened
and other protected species have been documented with high levels of Hg, and the livelihood and
reproductive success of these creatures can be affected by this and other hazardous pollutants, the EPA
is required to consult with the appropriate agencies to determine the levels at which emissions need to be
set not only as required under the Endangered Species Act (ESA) section 7(a)(2) but also to meet the
EPA's ESA section 7(a)(1) duty to determine how the EPA can use its authority to enhance the recovery
of these species.

698


-------
Response to Comment 7: The EPA generally agrees that such species are threatened by high levels of
Hg and other HAP and that actions to reduce those levels is appropriate. However, the commenters are
incorrect in their assertion that the EPA must conduct an ESA consultation in this action. In a challenge
to the NESHAP for primary copper smelters, the D.C. Circuit held that the ESA does not apply to the
MACT standard setting process under CAA section 112(d). Sierra Club V. EPA, 353 F.3d 976, 992
(D.C. Cir. 2004).

699


-------
CHAPTER 8: RULE LANGUAGE CORRECTIONS

8A - Rule: Definitions (existing)

Commenters: 17174, 17316, 17386, 17402, 17620, 17623, 17648, 17681, 17690, 17715, 17716, 17721,
17725, 17728, 17733, 17754, 17756, 17771, 17775, 17796, 17800, 17801, 17804, 17805, 17808, 17812,
17818, 17821, 17838, 17843, 17846, 17855, 17870, 17878, 17880, 17881, 17904, 17914, 18024, 18025,
18031, 18034, 18425, 18427, 18444, 18483, 18498, 18963, 19040, 19114, 18023

Several commenters requested that the EPA review the proposed definitions for consistency and clarity.

1. Definition of natural gas.

Comment 1: Multiple commenters (17174, 17801, 18483, 17878) request that the EPA review and
revise the definition of natural gas to be consistent with the NSPS. For natural gas, the third element of
the NSPS definition is excluded in the NESHAP definition (i.e., "A mixture of hydrocarbons that
maintains a gaseous state at ISO conditions. Additionally, natural gas must either be composed of at
least 70 % methane by volume or have a gross calorific value between 34 and 43 megajoules (MJ) per
dry standard cubic meter (910 and 1,150 Btu per dry standard cubic foot)"). Commenters 17801 and
17878 state that by excluding this provision, IGCC or other generating units will be subject to the same
standards as coal-fired boilers despite the fact they burn substitute natural gas (SNG), which is the same
chemically as natural gas. Should such IGCC or other generating units remain subject to the rule, fuel
sampling should be allowed as a compliance demonstration option in lieu of a Hg CEMS or sorbent trap
methodology due to Hg being removed from the fuel prior to combustion and the absence of post-
combustion Hg controls. If the EPA decides that the definitions should have different scopes and
limitations, the reasons for the divergent definitions should be clarified. Commenter 17174 also requests
that the EPA use the definition for distillate oil in the subpart Db NSPS, which contains a limitation on
the weight % nitrogen, while the proposed definition for the Utility MACT does not.

Response to Comment 1: The EPA concurs with the commenters concerning the definition of natural
gas from the NSPS and has made the suggested revisions to the 40 CFR subpart UUUUU definitions in
the final rule so as to be consistent with 40 CFR Part 75. Concerning the IGCC units, EPA must regulate
such units if the gas at issue is derived from coal or oil and EPA is listing coal- and oil-fired EGUs.
Although EPA believes that IGCC units could sample the gas stream before it enters the turbine, as
noted elsewhere in this document, EPA has dropped fuel sampling, and, thus, the issue is moot. Owners
or operators of IGCCs will need to perform instrumental monitoring (Hg CEMS or sorbent traps) or
quarterly emissions testing for mercury.

Natural gas means a naturally occurring fluid mixture of hydrocarbons (e.g., methane,
ethane, or propane) produced in geological formations beneath the Earth's surface that
maintains a gaseous state at standard atmospheric temperature and pressure under
ordinary conditions. Natural gas contains 20.0 grains or less of total sulfur per 100
standard cubic feet. Additionally, natural gas must either be composed of at least 70 %
methane by volume or have a gross calorific value between 950 and 1100 Btu per
standard cubic foot. Natural gas does not include the following gaseous fuels: landfill
gas, digester gas, refinery gas, sour gas, blast furnace gas, coal-derived gas, producer gas,
coke oven gas, or any gaseous fuel produced in a process which might result in highly
variable sulfur content or heating value.

700


-------
2. Definition of EGU.

Comment 2: Several commenters (17620, 17316, 17805) request that the EPA clarify in the final
regulations what the "25 MW" in EGU definition references. Commenter 17316 questions whether the
25 MW EGU threshold refers to the power supplied to the grid (i.e., the net MWs) or the power
generated by the EGU (i.e., the gross MWs). The commenter indicates that the 40 CFR 60.2 definition
of EGU implies that the net MW is of more relevant concern. Similarly, Commenter 17620 recommends
that the EPA specify whether the unit can produce more than 25 MWe is based on its maximum rated
capacity, short-term peak capacity, or if it is based on the unit's current ability taking into consideration
the age of the unit and its thermal efficiency.

Comment 3: Commenter 17805 requests that the EPA clarify that the definition of EGU is assessed by
reference to the maximum electrical generating capacity of the generator the combustion unit serves.
Thermal units, or boilers, are not, from an engineering standpoint, assigned MW or MWe ratings in
design or specification and are only known to be assigned to generator electric output (i.e., to the
generators a boiler serves). Thus, the thermal capabilities of a combustion unit are specified by reference
to generator output. The commenter requests that the definition of EGU should therefore be revised as
follows:

"Electric utility steam generating unit (EGU) means a fossil fuel-fired combustion unit
serving a generator of more than 25 megawatts (MWe) that serves a generator that
produces electricity for sale. A fossil fuel-fired unit that cogenerates steam and electricity
and supplies more than one-third of its potential electric output capacity and more than 25
MWe output to any utility power distribution system for sale is considered an electric
utility steam generating unit."

Comment 4: Commenter 18425 states that the definition of EGU is unclear for two reasons:

•	The phrase "of more than" can have multiple reasonable definitions (e.g., that a facility has the
capability to produce 25 MWe or that the facility is actually producing 25 MWe). The
commenter recommends that the definition should be clarified that EGUs will be affected by the
proposed rule if they are capable of producing 25 MWe rather than only when they produce 25
MWe during operation.

•	It is unclear if cogenerating units can be classified as EGUs using the first sentence of the
definition as it is currently written. The commenter recommends that the definition specify
whether cogenerating units apply.

Comment 5: Commenter 17818 supports the proposed definitions for fossil fuel, fossil fuel-fired and
the specification that an EGU must have fired coal or oil for more than 10.0 % of the average annual
heat input during the previous three calendar years or for more than 15.0 % of the annual heat input
during any one of those calendar years to be considered a fossil fuel-fired EGU but indicates that the
provision for combusting more than "73 megawatt-electric (MWe) (250 million British thermal units per
hour, MMBtu/hr) heat input (equivalent to 25 MWe electrical output) of coal or oil" is confusing. The
commenter suggests that it would seem to be more appropriate to consistently relate MW thermal as
fossil fuel fired heat input rather than MW electric (73 MW, or 73 MW thermal, or 73 MWhr/hr).

Comment 6: Alternatively, Commenter 17316 states that depending on the heat rate of an EGU, it may
require more or less than 250 MMBtu to generate 25 Mw of electricity. The commenter states that
referencing 250 MMBtu/hr as a threshold marker is confusing and 25 Mw alone should be used as the

701


-------
applicability threshold in all Sections of the rule for consistency and clarity.

Comment 7: Commenter 17386 states that the definition of "Electric utility steam generating unit"
provided in section 63.10042 of the proposed rule seems to include inconsistent designations. The
definition suggests the 25 MW threshold is a gross value for EGUs that output electricity only (1st
sentence) and a net value for EGUs that output steam and electricity (2nd sentence): "Electric utility
steam generating unit means a fossil fuel-fired combustion unit of more than 25 megawatts electric
(MWe) that serves a generator that produces electricity for sale. A fossil fuel-fired unit that cogenerates
steam and electricity and supplies more than one-third of its potential electric output capacity and more
than 25 MWe output to any utility power distribution system for sale is considered an electric utility
steam generating unit."

Commenter 17386 states that classifying EGUs based on their gross MW capacity, for EGUs that output
electricity also conflicts with the 40 CFR 60 definition that implies the 25 MW threshold is based on net
electrical output, as identified below: "Electric utility steam generating unit means any steam electric
generating unit that is constructed for the purpose of supplying more than one-third of its potential
electric output capacity and more than 25 MW electrical output to any utility power distribution system
for sale. Any steam supplied to a steam distribution system for the purpose of providing steam to a
steam-electric generator that would produce electrical energy for sale is also considered in determining
the electrical energy output capacity of the affected facility."

Commenter 17386-A2, therefore, requests that the EPA clarify the rule to identify whether the 25 MW
applicability threshold is based on gross electricity generation or net electrical output. The commenter
also recommends utilizing the 25 MW net electrical output approach consistent with the 40 CFR 60
definition in all sections of the MACT rule for consistency and clarity.

Comment 8: Commenter 17818 supports the applicability cutoff limit of greater than a 25 MWe rating
level, but questions the applicability of the proposed rule to EGU's that have an actual "nameplate"
rating capacity of 25 MWe or less but have actual demonstrated outputs of greater than 25 MWe.
Numerous examples of units with nameplate capacity listed as 25 MWe or less have demonstrated
summer and/or winter outputs of greater than 25 MWe, as documented in EIA listings. Conversely, the
EIA listings also identify EGUs with 25 MWe nameplate capacities that have actual demonstrated
output ratings less than 25 MWe. Such units that have actual ratings below the original nameplate may
have permit restrictions or other cycle restrictions that prevent the unit from attaining actual outputs
greater than 25 MWe. Units with 25 MWe nameplate rating but have demonstrated generation outputs in
excess of 25 MWe may have been under-rated from the manufacturer or may have undergone
modifications or operating practices that increase the output in excess of that anticipated by the
generator manufacturer. Commenter believes that the EPA must consider these circumstances in
determining unit applicability.

Comment 9: Commenters 17818 and 17843 support the EPA's proposed EGU exemptions as listed in
paragraphs (a) through (c) of section 63.9983.

Comment 10: Commenter 18031 agrees with the EPA's expanded EGU definition which supports
renewable energy from biomass, however clarification is needed to ensure that boilers which provide
steam to a generator <25 MW are not considered EGU's under the proposed EGU MACT Rule.
Commenter currently owns and operates four units that burn a combination of biomass, coal, and natural
gas. Commenter is in the process of upgrading these facilities in order to provide for even more biomass
generation to help meet a state mandate of 25 % renewable energy by 2025. Careful wording of the

702


-------
definition of an EGU in the proposed EGU MACT Rule is important to ensure the viable future of these
renewable energy sources.

Commenter 18031 states that the EGU definition in the proposed EGU MACT Rule allows for up to 10
% coal on a 3-year basis, and up to 15 % on a one-year basis, and these units would still qualify as
industrial boilers, even though the rated capacity is greater than 25 MW per unit. Two of Commenter's
four biomass units (located at the Hibbard Renewable Energy Center) are greater than 25 MW rated
capacity of the turbine/generator. Allowance for the use of coal for start-up and flame stabilization is
important due to the nature of the woody biomass combustion characteristics at these units. Biomass
heat content can vary from 2000 to 6500 Btu/lb with a moisture content ranging from 24 % to 65 %.

Coal helps to reduce the impact of this variability, resulting in better combustion and increased
operational stability.

Commenter 18031 states that because of the small size of these units, the emphasis on renewable
biomass generation, and the fact their primary function historically has been to provide steam to an
industrial process (paper mill), the Hibbard Renewable Energy Center boilers are more properly
classified as industrial boilers, not EGUs. Commenter supports retaining the language in the EGU
definition that would allow the continued use of coal for start-up and flame stabilization, and yet classify
these boilers as industrial boilers, not EGUs.

Commenter 18031 states that two of their boilers that burn primarily biomass were primarily designed
as industrial boilers to provide steam to a co-located paper mill. These two solid fuel boilers are both
rated at greater than 250 MMBtu/hr (270 MMBtu/hr), however the turbine/generator each unit serves is
less than 25 MWe, so these boilers should be classified as industrial boilers, not EGUs. CAA section
112(a)(8) defines an EGU as: "a fossil fuel-fired combustion unit of more than 25 megawatts electric

(MWe) that serves a generator that produces electricity for sale	" . ... Since the boilers do not feed

turbine/generators greater than 25 MWe, and have a primary purpose of providing steam to a paper mill,
they should not be classified as utility boilers. These boilers are more properly defined as industrial
boilers, and should fall under the Industrial Boiler MACT requirements. The definition of an EGU in the
final EGU MACT Rule should not require boilers rated at greater than 250 MMBtu/hr, but serving a
generator <25 MW, to meet the EGU MACT emission limits and other requirements.

Comment 11: Commenters 17316 and 17386 state that section 63.9983(c) of the proposed MACT rule
references an applicability threshold of 250 MMBtu/hr, with a parenthetical indicating that this heat
input is equivalent to 25 MW. Commenters note that, depending on the heat rate of an EGU, it may
require more or less than 250 MMBtu to generate 25 MW of electricity. Commenters state that
referencing 250 MMBtu/hr as a threshold marker is confusing; 25 MW alone should be used as the
applicability threshold in all sections of the rule for consistency and clarity.

Comment 12: Commenter 17733 strongly agrees with the preamble's statement that units that do not
meet the efficiency standards required to be a cogeneration unit should still qualify as EGUs if they
otherwise meet the definition of an EGU. Otherwise, owners of coal and oil-fired units would be
encouraged to avoid the EGU MACT requirements by reducing their units' efficiency. This result would
clearly be contrary to the intent of the CAA, and also clearly violate the EPA's Trust Responsibility and
its obligations under the Environmental Justice Doctrine. The commenter requests that the EPA should
make it clear in the final rule that any unit that does not meet the efficiency requirements of a
cogeneration unit will still qualify as an EGU if the unit otherwise meets the CAA EGU definition.

Further, Commenter 17733 strongly disagrees with the EPA's interpretation of the CAA section

703


-------
112(a)(8) definition "that a non-cogeneration unit must both have a combustion unit of more than 25
MWe and supply more than 25MWe to any utility power distribution system for sale to be considered an
EGU pursuant to this proposed rule so as to be consistent with the cogeneration definition in CAA
section 112(a)(8)." This interpretation is contrary to the plain language of the first sentence of CAA
section 112(a)(8). This sentence makes clear that an EGU includes "any fossil fuel-fired combustion unit
of more than 25 megawatts that serves a generator that produces electricity for sale." Nowhere does it
indicate that a non-cogeneration unit must supply more than 25 MWe to a utility-power distribution
system for sale to be considered an EGU.

Commenter 17733 states that the EPA's narrowing of the definition of an EGU is especially concerning,
since it is likely to exclude from the requirements of the EGU MACT Rule many older, less efficient,
and dirtier facilities. Owners of these facilities will likely be incentivized to reduce their electrical output
to just below 25 MWe and thereby avoid having to implement more effective Hg controls. This will
allow substantially more Hg contamination to occur, and therefore will be inconsistent with the EPA's
Trust Responsibility and the Environmental Justice Doctrine.

Commenter 17733 states that the EPA should make clear that units that fail to qualify as a cogeneration
unit will appropriately be considered an EGU if they meet the qualifications in the first sentence of the
EGU definition. This would mean that units that do not meet the efficiency standards for a cogeneration
unit are considered an EGU if they are a fossil fuel-fired combustion unit of more than 25 MW, that
serves a generator that produces electricity for sale (regardless of whether the generator actually supplies
more than 25 MWe to a utility power distribution system). By applying this standard, the EPA can
ensure that units that do not meet the cogeneration efficiency requirements are appropriately treated like
any other fossil fuel-fired unit. This will allow the EPA to help limit Hg emissions and therefore their
impact on Native American communities.

Comment 13: Commenter 17648 states that the EPA has scoped the Toxics Rule properly to apply to
EGUs that meet the definition of EGU in CAA section 112(a)(8). The affected sources will all be units
with original nameplate rate capacity of more than 25 MW, consistent with the statutory definition of
EGUs, thus excluding from the rule relatively small units.

Comment 14: Commenter 17775 supports the EPA's choice of dates for defining a new EGU.

Response to Comments 2 - 14: The EPA's interpretation of the statutory definition of the source
category found in CAA section 112(a)(8) (."..combustion unit of more than 25 megawatts...") is that it
clearly refers to the size of the combustion unit (i.e., boiler) rather than to the size of the generator. Thus,
EPA is not modifying the definition of an EGU such that it relies on the generator size as suggested by
some commenters as this would be outside EPA's authority. We do not interpret the CAA section
112(a)(8) definition to include consideration of the size of the generator for a non-cogeneration
combustion unit as long as the combustion unit itself is greater than 25 MW.

As noted by other commenters, boilers by themselves do not generate any electricity. The EPA had,
therefore, provided for clarity the general heat input equivalency. However, other commenters indicated
that this equivalency would not hold uniformly as a result of differences in boiler efficiency. Further,
EPA's stated intent was to use the "nameplate" capacity of the boiler (i.e., the design capacity expressed
on the "nameplate" affixed to the boiler). Absent such a "nameplate," the boiler size contained in the
original permit would serve as the "nameplate capacity." The EPA has re-evaluated its use of the term
"MW" and believes the correct interpretation would be "megawatt-thermal," or MWt (thermal power
produced by the combustion unit) as opposed to MWe which is the electric power generated by the

704


-------
generator. The EPA has modified the final rule to note only the 25 MW distinction for consistency and
clarity rather than the equivalent heat input. Further, EPA interprets the "more than" in the literal sense
to mean a combustion unit having a nameplate capacity (either original or modified) of greater than 25
megawatts regardless of its current operating capacity. Any combustion unit with a nameplate capacity
of 25 MW or less, regardless of the size of the generator being served, would not be subject to the final
rule.

The EPA agrees with the commenter that we erred in providing the "non-cogeneration" definition and
have removed it from the final rule. Further, EPA believes that the statutory definition for non-
cogeneration units is clear in CAA section 112(a)(8) and in the final rule, EPA adheres to that definition.
However, EPA believes that the commenter has misunderstood the provisions of the rule. There are no
"efficiency standards required to be a cogeneration unit" included in the proposed or final rule. There is
only the requirement contained in CAA section 112(a)(8) that the cogeneration unit supply "more than
one-third of its potential electric output capacity and more than 25 megawatts electrical output to any
utility power distribution system for sale..."

The EPA specified in Table 10 of the proposal preamble that the output-based emission limits (i.e.,
lb/MWh or lb/GWh) are specified as "gross." The EPA has made this clarification in the final rule.

4.	Definition of cogeneration facility.

Comment 15: Commenter 19040 questions why the definitions for a cogeneration facility differ in the
proposed rule and the Transport rule. The definition in the Transport Rule requires the cogeneration
system either be a topping-cycle or bottom-cycle unit and the electric sales onto the grid cannot exceed
the greater of one-third the nameplate capacity or 219,000 MWh per year.

Response to Comment 15: The EPA is operating under different statutory provisions for the Cross-
State Air Pollution Rule and the Mercury and Air Toxics Standards. We believe that our definitions in
each rule are consistent with the relevant statutory authority.

5.	Definition of "fossil fuel-fired."

Comment 16: Commenter 17733 supports the EPA's definition of "fossil fuel-fired," which helps
ensure that units cannot make short-term operational changes to avoid or delay meeting the requirements
of the EGU MACT Rule, consistent with the first sentence of the CAA definition and the EPA's
obligations under the Trust Responsibility and the Environmental Justice Doctrine.

Comment 17: Commenter 17805 recommends that the definition of "fossil fuel-fired" should also be
revised as follows for consistency:

"Fossil fuel-fired (or cogeneration means a cogeneration means an electric utility steam
generating unit (EGU) that is capable of combusting sufficient fossil fuel more than 73
MWe (250 million Btu/hr, MMBtu/hr) heat input (equivalent to 25 MWe output of fossil
fuels to generate 25 MWe from such fuels alone. To be "capable of combusting' ' fossil
fuels, an EGU would need to have these fossil fuels allowed in their permits and have the
appropriate fossil fuel handling facilities on-site (e.g., coal handling equipment, including
coal storage area, belts and conveyers, pulverizers, etc.; oil storage facilities). In addition,
fossil fuel-fired means any EGU that fired fossil fuels for more than 10.0 % of the
average annual heat input during the previous 3 calendar years or for more than 15.0 % of

705


-------
the annual heat input during any one of those calendar years."

Commenter 17880 also recommends this proposed definition of fossil-fuel fired.

Comment 18: Commenter 17796 recommends that the EPA revise the definitions for "fossil fuel" and
"fossil fuel-fired steam generating unit" to be consistent with the definitions of subpart D.

Comment 19: Commenter 17818 states that the definition of "fossil fuel-fired" units should be refined
to reduce confusion and inconsistencies. The commenter provides several examples where the language
uses both MW to convey fossil fuel-fired heat input and to convey MW electric. The commenter
suggests that it may be more appropriate to relate MW thermal as fossil fuel-fired heat input rather than
MW electric.

Response to Comments 16 -19: As noted in the preamble to the final rule, the EPA has made some
changes to the definition of "fossil fuel-fired" in the final rule; we believe the final definition to be
consistent with the statutory definition in CAA section 112(a)(8). In addition, as noted elsewhere, the
EPA has clarified its use of the term "MW" and has removed the than 73 MWe (250 million Btu/hr,
MMBtu/hr) equivalency term.

Comment 20: Several commenters indicated that the definition of "fossil fuel-fired" did not adequately
account for fuel switching and would require permit revisions to eliminate any mention of using coal or
oil to produce electricity and the removal of all coal handling equipment, coal storage areas.

Comment 21: Commenters 17756 and 17775 state that the definition of "fossil fuel-fired" EGUs may
potentially discourage natural gas and biomass conversions which require "bridging strategies." The
EPA views a unit as "capable of combusting" fossil fuels if burning those fuels is allowed in their
permits and they have the appropriate fuel handling equipment on site therefore the unit would be
subject to the proposed Toxics Rule. The commenter requests that the EPA revise the definition of
"fossil fuel-fired" EGUs.

Comment 22: Commenter 18023 requests that the EPA update the definition of "fossil fuel-fired" to
adequately account for fuel switching as a potential compliance strategy.

Response to Comments 20 - 22: The EPA does not agree with the commenters and we are not revising
that aspect of the definition of "fossil-fuel fired." The EPA does not agree that sources will have to
dismantle all their fossil-fuel handling systems and revise their Title V permits to prohibit fossil-fuel
combustion above a certain threshold, though either approach may be independently sufficient to make a
source incapable of combusting sufficient fossil fuel to meet the definition of "fossil-fuel fired." Sources
could retain both their fossil-fuel handling facilities and their Title V permit authority as long as the
source is not combusting fossil-fuel more than 10.0 % of the average annual heat input during the any
three 3 calendar years or for more than 15.0 % of the annual heat input during any one calendar years
after the applicable compliance date. The EPA believes the definition provides flexibility for sources
while simultaneously preventing sources from improperly avoiding regulation. EGUs that want to use
fuel switching as a compliance strategy should include in their Title V permit provisions that preclude
being coal- or oil-fired EGUs.

Comment 23: Commenters 18023 and 17775 state that the "look-back" period may potentially penalize
a unit that retains capability to combust fuels other than natural gas and units that previously burned coal
or oil. Commenter 18023 recommends that the EPA should eliminate the "look-back" period and define

706


-------
an affected unit by whether it actually has heat input exceeding the stated thresholds. A unit that,
beginning on the effective date, fires less than 15 % coal or oil on an annual basis (and less than 10 % on
a triennial basis) would not be considered "fossil fuel-fired" and would not be considered an affected
facility. Under this scenario, a unit that switches to natural gas and retains its capability to combust coal
or oil would not be penalized for burning coal or oil during the time period before the effective date.

Comment 24: Commenter 17775 recommends that the EPA should revise the definition to change the
"look-back" period to begin 3 years after the unit's final compliance date so that it does not penalize a
unit for having burned coal or oil in the period before compliance or for switching to natural gas but
retaining the ability to combust coal or oil (a desirable outcome to provide system reliability). The
commenter further states that unit owners would need to convert the unit to 100 % biomass or natural
gas within 3 years and remove all capability to burn coal or oil in order be exempt from the EGU MACT
rule. Alternatively, the unit could convert to biomass or natural gas by 2012 and ensure that the heat
input from coal or oil in 2012, 2013 and 2014 is below the annual 15 % heat input requirement and the
3-year requirement of 10 % heat input. Commenter 17775 also requests that the EPA clarify that a unit
that switches to natural gas and later switches back to highly controlled coal use would not be in
violation of the 3-year average for the years it was burning natural gas.

Response to Comments 23 and 24: As noted preamble to the final rule, the EPA has made changes to
the definition of "fossil fuel-fired" which we believe will address this comment. Further, a Title V
permit modification that prohibits the combustion of coal or oil would make the source incapable of
legally burning such fuels and would be sufficient to satisfy the requirements of the final rule.

6. Definition of "oil-fired electric steam generating unit."

Comment 25: Commenter 17805 recommends that the definition of "oil fired electric steam generating
unit" should be revised as follows for consistency:

"Oil-fired electric utility steam generating unit means an electric utility steam generating
unit that either burns oil exclusively, or burns oil alternately with burning fuels other than
oil at other times. In addition, oil-fired means any EGU that fired oil (or more than 10.0
% of the average annual/teat input during the previous 3 calendar years or (or more than
15.0 % of the annual/teat input during any one of those calendar years."

Comment 26: Commenter18024 submits that the EGU MACT Rule should exclude the fuel input
associated with complying with state reliability requirements from the heat input calculation for the
liquid oil-fired unit subcategory. Commenter requests that the EPA add the following language to the
proposed definition of "units" designed to burn liquid oil fuel:

"Units designed to burn liquid oil fuel subcategory includes any EGU that burned any
liquid oil for more than 10.0 % of the average annual heat input during the previous three
calendar years or for more than 15.0 % of the annual heat input during any one of those
calendar years, either alone or in combination with gaseous fuels, provided, however, that
liquid oil burned during the three calendar year period to meet state reliability
requirements shall be excluded from the heat input calculation."

Alternatively, Commenter18024 would support changing the applicability definition for "units"
designed to burn liquid oil fuel from > 10 %/15 % of actual heat input to >30 % of actual heat input (3-
year rolling average). Based on historical operation, the commenter believes that 30 % oil firing at a

707


-------
facility would be sufficient to provide needed reliability in conformance with the State reliability rules.

Comment 27: Commenter 17725 notes that the definition for "oil-fired EGU" may have the unintended
consequence of excluding some units using emissions averaging. The proposed regulations state that
emissions averaging can only be used for units within the same subcategory at the same location, and
under the common control of the same person. But, as the fuel use of the dual-fueled units is managed at
the site to meet the requirements of averaging, there is the risk that an individual dual-fueled EGU at the
site may use more than 85-90 % natural gas, and therefore may no longer meet the definition of "oil-
fired EGU." If a unit does not meet the definition of "oil-fired EGU" then, it is ineligible to be used in
the averaging strategy.

Response to Comments 25-27: As stated in the preamble to the final rule, the EPA is establishing a
limited-use liquid oil-fired EGU subcategory and sources in the subcategory will be required to comply
with work practice standards. See the preamble for specific responses to the comments.

7. Definition of "coal-fired electric utility steam generating unit."

Comment 28: Commenter 17805 recommends that the definitions of "coal-fired electric utility steam
generating unit" should be revised as follows for consistency:

"Coal-fired electric utility steam generating unit" means an electric utility steam
generating unit meeting the definition of "fossil fuel fired" that burns coal or coal refuse
either exclusively, in any combination together, or in any combination with other fuels in
any amount. In addition, coal-fired means any EGU that fired coal for more than 10.0 %
of the average annual/teat input during the previous 3 calendar years or for more than
15.0 % of the annual/heat input during any one of those calendar years.

Comment 29: Commenter 17623 requests that the EPA update the definitions to clearly state that the
emissions standards applicable to coal-fired units also apply to any EGU using any amount of coal or
coal refuse, whether blended with other fuels or burning both coal and petcoke. The commenter states
that although the preamble contains the appropriate language, the definitions for each subcategory could
be interpreted differently if read separate from the preamble. The commenter recommends that the final
rule clearly specifies that the standards for coal-fired units apply in cases where an EGU is burning coal
or any combination of coal and another fuel.

Response to Comments 28 - 29: As stated in the preamble to the final rule, the EPA is revising the
definition of "coal-fired electric utility steam generating unit." We believe this is appropriate to be
consistent with the definition of "fossil-fuel fired." We are making a similar change to the definition of
"oil-fired" EGU and adding a definition for "natural gas-fired" EGU. We think these definitional
changes provide clarity to the approach we proposed. In addition, EPA has revised the definitions to
make clear that a unit is not an oil-fired EGU if it meets the definition of "coal-fired EGU."

Comment 30: Commenter 17868 disagrees with the EPA's decision not to include petcoke in the coal
subcategory and urges EPA to review UARG's comments on the subject.

Comment 31: Commenters 17623 and 18034 recommend that the coal subcategorization definitions
should be reviewed and revised for clarity.

Comment 32: Because the EPA chose not to subcategorize based on coal rank or liquid fuel type (i.e.,

708


-------
No. 2/ No. 6), Commenter 17881 believes that fuel type should correspond to the subcategory definition.
As long as the emission limits are being met for the applicable subcategory, the blend of
bituminous/sub-bituminous or other solid fuel should not matter. The same can be said for different
ranks of liquid fuels. Ultimately, compliance is based on the subcategory definition, not on fuel types,
and the onus is on the facility to demonstrate compliance.

Response to Comments 30 - 32: The EPA generally agrees with the commenters' characterization of a
sources responsibility to assure its compliance with the final rule. The EPA has revised the definitions in
the final rule in a manner that we believe provides added clarity. As petroleum coke (pet coke) is
derived from liquid oil rather than coal, we believe it appropriate to maintain it as a subcategory of oil.

Comment 33: Commenter 18034 suggests that the coal subcategorization definitions be based solely on
fuel heat content design criteria. Alternatively, the EPA should provide a definition of height-to-depth
ratio to avoid misinterpretation regarding applicability of coal units since some investigators not have
the necessary information to verify the proper categorization of a unit. The commenter further suggests
that may create an inadvertent loop-hole in the rule if a unit is designed to burn coal with heat content
greater than 8,300 Btu/lb and a height-to-depth ration greater than 3.82, and therefore would not be
subject to the emission limits.

Comment 34: Commenter 17914 states that it is the fuel properties that impact the potential Hg
emissions rate and submits that they have designed and supplied boilers to burn similar low-rank coals
with lower height-to-depth ratios than the proposed ratio cut-off of 3.82 in the U.S. EGU market. The
commenter believes the ratio was determined directly from Figure 19 of Chapter 20 in, "Steam/its
generation and use," 40th Edition but states that the dimensions are illustrative only and do not reflect a
firm design criteria. The commenter respectfully questions the significance of the boiler dimensional
criterion as a condition for establishing the Hg emissions limit for an existing EGU and states that an
arbitrary limit on HID may actually prohibit a designer from reaching the most optimized combustion
system and furnace design for new EGUs. Like commenter 18034-A3, Commenter 17914 requests that
the EPA consider using the noted fuel characteristic as the sole criteria for defining the appropriate Hg
emissions limit.

Comment 35: Commenter 17846 states that the definition "burn lignite coal" provides too much
flexibility for EGUs to switch categories by simply changing their fuel source and does not make clear
that the 3.82 height to depth ratio applies to the EGU furnace and not the EGU as a whole. The
commenter requests that the EPA revise the rule's definition to limit the subcategory to "any EGU
designed to burn only [lignite coal] in an EGU with a height-to-depth ratio of 3.82 or greater."

Response to Comments 33-35: The EPA does not believe it appropriate to base the subcategorization
solely on the fuel heat content. However, the EPA has revised the definition of the subcategory to more
adequately define the subcategory without precluding fuel blending. The EPA does not believe that units
designed to burn this low rank virgin coal will be constructed outside the area where the coal is found
because of the unique considerations that are involved; proximity to the mine has been included in the
definition.

8. Definition of "coal refuse."

Comment 36: Multiple commenters (17754, 17855, 17812, 17838, 18963, 17804) recommend that the
definition of coal refuse be reviewed and updated to account for the documented and inherent variability
of the fuel source. The commenters note that the definition of "coal refuse" in the proposed rule contains

709


-------
additional qualifying language that requires material to exhibit "ash content greater than 50 % (by
weight) and a heating value less than 13,900 kilojoules per kilogram (6,000 Btu per pound) on a dry
basis to be defined as coal refuse." Therefore, much of the coal refuse combusted would not meet the
applicable definition because it would not satisfy the applicable ash content and heating value
criteria. The commenters requests that the EPA revise the definition of "coal refuse" under the proposed
rule by eliminating the restrictions on heating value and ash content to account for the variability and be
consistent other federal regulatory language.

Comment 37: Commenter 17855 states that the definitions do not seem to incorporate waste-coal power
plants as affected facilities, although we believe it is the EPA's intent that these plants be regulated as
EGUs under this rule. Similarly, Commenters 17754, 17838 and 18963 question how a unit combusting
coal refuse that does not satisfy the definitions under the proposed rule of either coal refuse or coal
would be classified, and whether it would therefore effectively avoiding regulation under the proposed
rule altogether. The commenters further state that the heating value and ash content within the proposed
definition of "coal refuse" are inconsistent with the EPA's clear recognition in the preamble to the
proposed rule of the environmental benefits associated with the combustion of coal refuse.

Comment 38: Commenter-17812 states that waste-coal plants that are classified as Qualifying Facilities
either as Independent Power Production Facilities or Cogeneration Facilities burning waste-coal had
their fuel supply certified by FERC. The commenter refers to the preamble and its reference to the
NHSM rule that currently-mined coal refuse should not be considered a solid waste under the Resource
Conservation and Recovery Act (RCRA), as long as it is not discarded. The NHSM rule further states
that the coal refuse would be subject to the Utility MACT regulation, if the unit meets the definition of
EGU. The commenter indicates that the definition of coal refuse should be revised so that coal refuse
can be subject to the Utility MACT regulations, consistent with the language of the NHSM rule.

Comment 39: Commenter 17880 states that if a unit combusts coal by-products, it should be subject to
regulation under CAA section 129 - Solid Waste Combustion Rule. In February of 2011, the EPA
determined that unless processed coal refuse is discarded, it cannot be considered solid waste under the
Non-Hazardous Solid Waste Definition Rule.

Response to Comments 36 - 39: The EPA has revised the definition of "coal refuse" to be consistent
with the definition found in 40 CFR subpart Da. The EPA believes that the definition of "Coal-fired
electric utility steam generating unit" already clearly states that coal refuse is a covered fuel. Units
burning coal refuse and not meeting the definition of an EGU in the final rule would likely be subject to
the Industrial Boiler NESHAP (40 CFR Part 63, subpart DDDDD).

Certification of a fuel by FERC or any other body does not supersede the appropriate definitions
applicable to CAA section 112. EGUs burning a coal refuse meeting the definition of a "solid waste"
under the NHSM rule would be subject to standards issued pursuant the CAA section 129 (e.g., the final
CISWI rule); however, we did not identify in the proposed rule any EGUs that are burning coal refuse
that is a solid waste. Furthermore, no units indicated in comments that they are burning coal refuse that
is a solid waste so all units that meet the definition of EGU and combust coal refuse are subject to this
final rule.

9. Definition of fossil fuel.

Comment 40: Commenter 18427 requests that the EPA revise the definition of "fossil fuel" in the
proposed Utility MACT as follows:

710


-------
"Fossil fuel means natural gas, oil, coal and any form of solid, liquid, or gaseous fuel
derived from such material for the purpose of creating useful heat."

The commenter states that there is no justifiable basis to define the term "fossil fuel" meaningfully
differently under the two relevant regulatory programs, both of which apply to fossil fuel-fired electric
utility steam generating units. Further, revising the definition of fossil fuel under the proposed Utility
MACT in this manner will ensure consistent application of the applicable regulatory standards to these
units.

Further, the commenter requests that the EPA clarify within subpart Da and the proposed Utility MACT
that the definition of "fossil fuel" does not include landfill gas, biogases or other materials such as
engineered fuels that are produced from processing components of municipal solid waste. The
commenter believes that the EPA has not intended to include landfill gas or other biogases within the
definition of "fossil fuel," but states that there is some ambiguity presented by the definitions included in
the proposed rules as drafted because both the proposed Utility MACT and the proposed revision to
subpart Da define and use the term "gaseous fuel" (which is contained within the definition of "fossil
fuel") to encompass a broader category of fuels than fossil fuels.

The commenter also requests:

•	EPA clarify in the context of the proposed rules that neither subpart Da nor the proposed Utility
MACT would apply to a unit which exclusively or primarily combusts a "gaseous fuel" that is
not otherwise a fossil fuel.

•	EPA clarify the circumstances under which a non-fossil gaseous fuel-fired unit may be affected
by the proposed rules.

•	To the extent that use of a non-fossil gaseous fuel may be covered under subpart Da or the
proposed Utility MACT under certain circumstances, the proposed rules should be clear with
respect to the manner in which such non-fossil gaseous fuels may be affected.

Response to Comment 40: Some fossil fuels in current use at EGUs (e.g., petroleum coke) were not
derived for the purpose of creating useful heat. Therefore, including this phrase in the definition as
commenter suggests would preclude coverage of an EGU burning pet coke under the final rule unless
the unit blended the pet coke with coal such that the unit met the definition of "coal-fired electric utility
steam generating unit." The EPA recognizes that there may be differences in the definition of "fossil
fuel" among the different regulatory actions, but we have determined that byproducts of fossil fuels
should be regulated for HAP in the same manner as raw fossil fuels because the fuel-borne HAP content
is the same as the raw fuel, regardless of whether there was an intent to create the byproduct for the
purpose of creating useful heat. For example, pet coke contains the same fuel borne HAP as the raw
fossil fuel from which it is derived (i.e., oil). In addition, although pet coke is a byproduct of oil refining,
it is also currently recognized as a valuable fuel commodity, which was not the case when the 40 CFR
Part 60, subpart Da definition was promulgated. For these reasons, we are retaining the proposed
definition.

The EPA believes that the definitions are sufficiently clear that only fossil fuels, or fuels derived from
fossil fuels, are covered under the final rule. Materials noted by the commenter (e.g., landfill gas,
biogases, materials derived from municipal solid waste) are, in EPA's opinion, clearly not derived from
"fossil fuel" and, thus, not covered under the final rule. "Gaseous fuel" in the definition of "fossil fuel"
is clearly linked to fossil fuels through the "derived from" phrase. The EPA does not believe that there is
any confusion in the definition.

711


-------
10. Definitions of miscellaneous terms.

Comment 41: Several commenters note inconsistent definitions for operating limits. Commenters
17716 and 18498 state that the PM operating limit is defined in section 63.10011(d) as "the average of
the PM filterable results" of the three Method 5 performance tests runs and as "at or below the highest 1-
hour average" measured during the most recent performance test in Table 4. The commenters suggest
that the inconsistency should be eliminated by using a filterable PM (FPM) limit as a surrogate for non-
Hg metal HAP instead of total PM (TPM). However, if a PM operating limit is used, the inconsistency
between sections should be reviewed and corrected.

Response to Comment 41: The comment is moot because rule now allows compliance with filterable,
not total, particulate matter (PM).

Comment 42: Commenter 17800 states that the EPA provides four inconsistent definitions for
minimum control device operating parameters in:

•	the preamble ("The average of the three minimum (or maximum) values from the three runs for
each applicable parameter would establish a site-specific operating limit."(FR Vol. 76, No. 85, p.
25,029));

•	Section § 63.10042 ("90 %" of the "test average" during the most recent performance test);

•	Table 4 ("at or above the lowest 1-hour average"); and

•	Table 8 ("12-hour block average" "at or above" the operating limit established under
§ 63.10011(c)).

The commenter recommends that the EPA adopt the "90 %" criterion and the 12-hour-block average to
provide some level of flexibility to account for changes in unit operation. Furthermore, the commenter
requests that the EPA provide data to support achievability or enforceability of operating parameters
under the final definition.

Response to Comment 42: This comment is moot because rule no longer requires parameter
monitoring or operational limits for pollution control devices.

Comment 43: Commenter 18444 supports limiting emissions of total filterable and total condensable
PM and therefore recommends that the PM definition in the proposed rules include the sum of the total
filterable and total condensables.

Response to Comment 43: As explained elsewhere, the rule now uses filterable PM as an indicator of
non-Hg metals since filterable PM, total PM and total PM2.5 provided comparable correlations with the
metals emissions. As a result, the comment requesting a definition clarifying that total PM emissions is
the sum of the condensable and filterable PM is moot.

Comment 44: Commenter 18023 requests that the EPA revise the definition of an operating day to be
consistent with the NSPS. Specifically, the commenter suggests that the definition of an operating day's
worth of data in section 5.2. 1, Sorbent Trap Monitoring Systems, should include no less than 18 hours
of valid data rather than only 15 minutes.

Response to Comment 44: The commenter's suggestion to establish a minimum data collection period
that would constitute a boiler operating day is inconsistent with the Agency's view that data collection,
as well as emissions control device operation, needs to occur during each period of unit operation,

712


-------
regardless of the duration. The rule maintains requirements to operate the monitoring system and collect
data at all required intervals at all times that the affected unit is operating, except for periods of
monitoring system malfunctions or out-of-control periods and periods of monitoring quality checks, and
to use all data collected outside these periods in assessing continuous compliance.

Comment 45: Commenter 17681 requests that the EPA clarify the definition of a "30 Operating Day
Rolling Average" as well as the methods used to calculate the average. Commenter requests that the
EPA clarify that a 30-operating day is based on the average of all applicable hours in the 30-day period.

Response to Comment 45: The agency is unsure of the commenter's clarification request, as a 30 boiler
operating day rolling average is the average of all the hourly values calculated over 30 previous,
consecutive boiler operating days. The equation is as follows:

1 30

30 boiler operating day rolling average = — ^ hourly averagek

k=1

where k = individual hourly average over previous 30 days on which fuel was combusted.

The rule contains a definition of boiler operating day in section 63.10042 and the equation in section
63.10021(b)(3).

Comment 46: Commenter 17721 requests that the EPA revise the definition of "minimum sorbent
injection rate" on page 25123 of the proposed rule as follows:

"Minimum Sorbent Injection or Addition Rate means 90 % of the test average sorbent
injection or addition rate for each sorbent measured according to Table 7 to this subpart
during the most recent performance test demonstrating compliance with the applicable
emission limits."

Response to Comment 46: This comment is moot because rule no longer requires monitoring of the
sorbent injection rate.

Comment 47: Commenters 17801 and 17821 recommend that the EPA modify the proposed definition
(p. 25123) of gross output as follows:

"Gross output means the gross useful work performed by the steam generated and, for an
IGCC electric utility steam generating unit, the work performed by the stationary
combustion turbines. For a unit generating only electricity (including IGCC), the gross
useful work performed is the gross electrical output from the unit's turbine/generator sets
(including steam turbines). For a cogeneration unit, the gross useful work performed is
the gross electrical, including any such electricity used in the power production process
(which process includes, but is not limited to, any on-site emission controls), or
mechanical output plus 75% of the useful thermal output measured relative to ISO
conditions that is not used to generate additional electrical or mechanical output or to
enhance the performance of the unit (i.e., steam delivered to an industrial process)."

Response to Comment 47: The EPA has modified the definition in the final rule as follows:

Gross output means the gross useful work performed by the steam generated and, for an

713


-------
IGCC electric utility steam generating unit, the work performed by the stationary
combustion turbines. For a unit generating only electricity, the gross useful work
performed is the gross electrical output from the unit's turbine/generator sets. For a
cogeneration unit, the gross useful work performed is the gross electrical, including any
such electricity used in the power production process (which process includes, but is not
limited to, any on-site processing or treatment of fuel combusted at the unit and any on-
site emission controls), or mechanical output plus 75 % of the useful thermal output
measured relative to ISO conditions that is not used to generate additional electrical or
mechanical output or to enhance the performance of the unit (i.e., steam delivered to an
industrial process).

Comment 48: Commenters 1780 land 17821 recommend modifying the definition of Heat Input (p.
25,123) as follows: "Heat Input means heat derived from combustion of fuel in an EGU (synthetic gas to
the combustion turbine for IGCC) and does not include the heat input from..." This will help avoid any
confusion or inconsistent application of using coal in lieu of syngas as the basis for any values based on
heat input.

Response to Comment 48: The EPA has modified the definition in the final rule as follows:

Heat input means heat derived from combustion of fuel in an EGU (synthetic gas for an
IGCC) and does not include the heat input from preheated combustion air, recirculated
flue gases, or exhaust gases from other sources such as gas turbines, internal combustion
engines, etc.

Comment 49: Commenter 17821 supports the rule's proposed definition for fuel type, specifically
agreeing that receiving fuel from different suppliers does not constitute a change in fuel type.

Response to Comment 49: The EPA appreciates the commenter's support. The EPA has made
revisions to certain definitions as discussed elsewhere to provide clarity in the final rule.

Comment 50: Commenter17402 suggests that the EPA's definition of "deviation" is too broad and
results in excessive infeasible reporting requirements. The commenter recommends that operating limits
and monitoring requirements should not be included in the definition. Additionally, the commenter
recommends that any notification of exceedances should be reported in semiannual compliance reports
rather than the current proposed notification schedule.

Response to Comment 50: Even though the agency disagrees with the commenter's view, a rule change
to drop almost all operating limits and control device parameter monitoring in favor of frequent
emissions testing or continuous monitoring should alleviate the commenter's concerns. The proposed
notification schedule for deviations from operating limits established by unit owners or operators by
choice for non-mercury metals monitoring and for fuel oil moisture monitoring for hydrogen halides will
remain. The EPA has modified the definition of "deviation" in the final rule as follows:

Deviation.

(1) Deviation means any instance in which an affected source subject to this subpart, or
an owner or operator of such a source:

(i)	Fails to meet any requirement or obligation established by this subpart including, but
not limited to, any emission limit, operating limit, or work practice standard; or

(ii)	Fails to meet any term or condition that is adopted to implement an applicable

714


-------
requirement in this subpart and that is included in the operating permit for any affected
source required to obtain such a permit.

(2) A deviation is not always a violation. The determination of whether a deviation
constitutes a violation of the standard is up to the discretion of the entity responsible for
enforcement of the standards.

Comment 51: Commenter 17838 states that the definition of FGD creates confusion because the first
sentence of the definition appears to state that any dry FGD technology shall require an "add-on air
pollution control system located downstream of the steam generating unit." In order to avoid the
potential inconsistency between these two sentences of the definition, the Commenter recommends that
the EPA revise the definition of FGD to expressly state in the second sentence that the sorbent injection
system in a CFB boiler need not be a separate add-on air pollution control system located downstream of
the steam generating unit.

Response to Comment 51: We believe that the last sentence of the definition ("Sorbent injection
systems in fluidized bed combustors (FBC) or circulating fluidized bed (CFB) boilers are included in
this definition.") clearly indicate that the Agency considers CFB to be a "dry flue gas desulfurization
technology." However, we have made a minor edit to the definition to indicate that alkaline sorbent must
be used in CFB units to qualify.

Comment 52: Commenter 17771 requests that the EPA revise the language defining the work practice
standard requirement to "optimize combustion" to avoid a situation where facilities might be required to
completely shut down operations every 12 to 18 months in order to achieve compliance.

Response to Comment 52: Although the rule does not define the work practice standard requirement to
"optimize combustion," the final rule increases the time between burner inspections to 36 months and to
48 months for EGUs that employ neural net technology. This lengthening of time better coincides with
routine boiler inspections and should alleviate the commenter's concerns over frequent, premature
shutdowns.

Comment 53: Commenter 17655 states that the rule does not clearly define the term "optimize" with
respect to the work practice standard for organic HAPS. Section 63.10021 (a)(16)(iv) includes a
subjective requirement to "optimize" total emissions of CO and NOx per manufacturer's specifications,
but the commenter argues that the term needs to be defined so that it is not interpreted as "minimized" or
"balanced" by future facilities seeking compliance. The commenter suggests that an operational
definition should aim to yield reduced CO levels and comply with applicable NOx limits throughout the
normal range of operation and suggests that manufacturers' recommendations, if available, could be of
considerable assistance in developing the definition.

Response to Comment 53: The EPA recognizes the economic drivers behind optimal combustion of
fuel to maximize output while minimizing fuel costs, and the EPA recognizes the nuances of managing
NOx emission limits with these optimization efforts. Rather than drive tuning toward "minimal NOx" or
"minimal CO" thresholds, we have developed language requiring tuning to conform with "best
combustion engineering practice" for each burner type affected. We expect owners or operators of
EGUs to maintain the balance of optimal combustion with NOx control and use sound combustion
engineering practice to maintain that balance. In the final rule we have also added incentives for units
that employ neural net combustion optimization systems during hours of normal operation.

Comment 54: Commenter 17728 indicates that the definitions for major and area sources are

715


-------
inconsistent within section 112(a). The section defines major and area sources as any "stationary source
located within a contiguous area and under common control." The section also declares that the
"stationary source" term is defined in CAA section 111(a), stating that "any building, structure, facility,
or installation which emits or may emit any air pollutant."

Response to Comment 54: The EPA did not provide definitions for "major source" or "area source"
within the final preamble. Instead, EPA relies on the definitions as they appear in CAA section 112.

716


-------
8B - Rule: Definitions (new)

Commenters: 17655, 17696, 17711, 17718, 17721, 17725, 17755, 17760, 17800, 17808, 17878, 17881,
18025

Comment 1: Several commenters (17760, 17718, 17808, 18025) recommend new definitions with
regard to oil-fired units to ensure that applicability is capacity-based. Commenter 17760 and 17718 state
that the EPA should adopt the term "oil-affected units" to address oil-fired and oil- and gas-fired units
that have low capacity factors on oil fuel usage. In the proposed rule, the definition determines whether
a unit that combusts oil is an affected unit based on the percentage of oil combusted by the unit
compared to its total heat input. Because the exclusion is based on a fuel combustion ratio, a unit that
operates for only two days (one on oil, one on gas) could be subject to the proposed rule, and a unit that
combusts the same quantity of oil as the first unit but operates for multiple days on gas to be excluded.
Such an arbitrary result is possible given the current operating practices for oil and oil/gas units. Since
the promulgation of the Acid Rain Program regulations in 1993, the operation of oil- and oil/gas-fired
units has changed significantly. A large fraction of these units are no longer base load units, and
typically operate at capacity factors well below 50 %. In many cases, the capacity factor is less than 15
%. The EIA Annual Energy Outlook 2011 forecasts that the amount of liquid fuels used for electricity
generation in 2015 will be approximately 60 % lower than 2000 levels.

The commenters suggest that the EPA define an oil-affected unit (an oil-fired unit that is subject to the
EGUMACT rule) as:

"A unit that had a three-year average oil heat input greater than 10 % of the maximum
potential annual heat input, calculated by multiplying the maximum design heat input by
8760. This definition would ensure that the EGU MACT rule targets EGUs with greater
HAP emissions from the combustion of oil, and address EPA's concerns regarding
limited use oil-fired units, which typically operate at very low capacity factors."

Response to Comment 1: As noted elsewhere, the EPA has modified the definition of "oil-fired" EGU.
A discussion of the limited use issue is provided elsewhere in the final rule record.

Comment 2: Commenters 17808 and 18025 request that the EPA adopt a definition for a limited-use
oil-fired EGU, which is any boiler that burns any amount of liquid oil, has a rated capacity of greater
than 25 MW, and has an annual average capacity factor based on its oil use of 10.0 % or less over the
past 3 years (and not more than 20.0 % in each of those 3 years). The commenters recommend this
definition it reflects the varying loads of an EGU and is precedented in Part 75. The commenters also
suggest that that "capacity factor" is the ratio of the unit's actual annual oil heat input to the unit's
maximum design heat input times 8,760.

Response to Comment 2: A discussion of the limited use issue is provided elsewhere in this document.

Comment 3: Commenter 17725 proposes that the EPA adopt a new definition, "Oil-fired facility for site
averaging," to account for the event that a site meets its emissions limits but may have individual dual-
fired units which do not meet the oil-fired EGU definition. Currently, the source owner may be forced to
operate the EGU on oil just to maintain the EGU's oil-fired status and eligibility for inclusion in the
averaging calculation, resulting in additional emissions with no compliance benefits. In fact, based on
the amount of oil-firing needed, the site's emissions average may increase to the point where site-wide
compliance is not attained. The commenter recommends a definition based on the total average oil-fired

717


-------
heat input for all EGUs within the site averaging plan as follows:

"For purposes of site averaging, the subcategorization for individual EGUs shall be based
on the EGU's operation prior to the effective date of the regulations. Upon the effective
date of the regulations, subcategorization shall be based on the total oil-fired heat input
divided by the total heat input from all fuels from the affected EGUs An Oil-fired facility
shall have an average annual heat input on oil more than 10.0% for the 3 calendar years
prior to the effective date of the regulations or more than 15.0 % for any single year
within the three-year period."

The commenter states that this definition encourages the use of lower emitting fuels through emission
averaging but does not limit compliance options or require mandatory oil-firing to maintain an EGU's
oil-fired status.

Response to Comment 3: As noted elsewhere, the EPA has modified the definition of "oil-fired" EGU.
Discussions of the limited use and site averaging issues are provided elsewhere in this document.

Comment 4: Commenter17800 recommends that the EPA provides definitions for certified Flow, CO2,
or O2 monitoring systems, with respect to appendix A, subpart UUUUU. The commenter inquires as to
whether the certification refers to CFR Part 75 or Part 60.

Response to Comment 4: In the final rule, section 3.2.3 of Appendix A explicitly states that the
certified flow rate, diluent gas, and moisture monitoring systems that are used to convert Hg
concentrations to units of the standard must be installed, certified, operated, maintained, and quality-
assured according to 40 CFR Part 75. This is reinforced by §§63.10010(b) through (d).

Comment 5: Commenter 17715 recommends that the EPA use the part 72 definitions for CO2 and flow
range determination and the definition for zero gas to provide an accurate definition which harmonizes
the definitions across more than one rule.

Response to Comment 5: The agency agrees with the commenter, and, as part of its review to reduce
burden and costs, decided to better integrate MATS monitoring requirements with those of the Acid
Rain program. As a result, and as mentioned elsewhere, the rule builds off the Acid Rain program
requirements whenever possible.

Comment 6: Commenter 17711 requests that the EPA add a definition for fuel cell to avoid any
misinterpretations. Although the commenter believes the steam generating unit language is intended to
address integrated gasification fuel cells, the wood products industry commonly uses the term fuel cells
to refer to biomass combustion devices.

Response to Comment 6: Fuel cells as noted by commenter would not be EGUs under the final rule as
they are biomass-fired and, thus, not fossil fuel-fired.

Comment 7: Commenter 17721 proposes that the EPA add the following definition of DLPS to section
63.10042 of subpart UUUUU of the proposed rule (page 25121):

"Dual liquid powder sorbent injection (DLPS) is an Hg-control technology where a liquid
sorbent is added onto the coal before combustion and a powder sorbent is mixed with the
coal, injected into the furnace, or is duct injected. The liquid sorbent is a water solution of

718


-------
a bromine compound, while the powder sorbent is an alkaline powder containing calcium
and significant levels of aluminosilicates."

The commenter further suggests that the following language be added to the proposed rule to expressly
authorize or at least recognize DLPS systems as available emissions control technology:

•	(at the fourth-to-last sentence in section III.D.6.C, which appears on page 25014 of the proposed
rule) "Hydrogen chloride and HF have also been shown to be effectively removed using DSI
where a dry, alkaline sorbent (e.g., hydrated lime, trona, sodium carbonate) is injected upstream
of a PM control device, or when powder sorbents such as those used in a dual liquid-powder
sorbent system are combined with coal or injected into the fireball of the furnace."

•	(at the second-to-last paragraph in section III.D.6.C, which appears on page 25014 of the
proposed rule) "The use of halogen additives in combination with powders containing calcium
and aluminosilicates leads to significant reduction of SO2 as well as nearly complete control of
emitted Hg. A dual liquid-powder sorbent ("DLPS") system consists of adding an aqueous
solution of a halogen, especially a bromine compound, onto the coal upstream of the furnace.
Then a powder sorbent containing calcium and aluminosilicates is injected into the furnace
during combustion of the halogen-containing coal. With some fuels, adequate Hg control is
achieved with only the powder sorbent. Whether halogen is added or not, the use of the powder
sorbent results in capture of the Hg and other HAP metals in a microencapsulated non-leaching
form in the ceramic matrix of the coal ash remaining from combustion. Such methods are in
commercial use and perform well with high sulfur coals, as it provides for sulfur removal as
well. An additional advantage is that the Hg and other HAP metals are bound tightly in the fly
ash so that they do not leach from the ash during storage or reuse, including during reuse in
concrete."

•	(after the sentence beginning "Activated carbon injection is the most successfully demonstrated
Hg-specific control technology," in section D.8.c, which appears on page 25017 of the proposed
rule) "On the other hand, the effectiveness of the dual liquid-powder sorbent ("DLPS") system
for controlling S02, Hg, and other HAP metal emissions may not be compromised by the sulfur
content of the coal."

Commenter 17721 also suggests that the following language be added to the rule:

•	(following sentence in section III.E, which appears on page 25023 of the proposed rule)
"Hydrogen chloride also has a large acid dissociation constant (i.e., HC1 is a strong acid) and
it, thus, will react easily in an acid-base reaction with caustic sorbents (e.g., lime, limestone),
including the powder sorbent containing calcium and aluminosilicates used in the Chem-Mod
DLPS system."

•	(at the first sentence in section IV.I.(6)(3), which appears on page 25030 of the proposed rule)
"For units with dry scrubbers, DSI (including ACI), or DLPS, you would be required to measure
the sorbent injection or addition rate for each sorbent used during the performance tests for HC1
and Hg and determine the minimum hourly rate of injected sorbent for each test run."

•	(at the last sentence in section IV. J. 1 .(3), which appears on page 25031 of the proposed rule)
"For units with dry scrubbers, DSI systems, or DLPS systems we are proposing that you
continuously monitor the sorbent injection or addition rate and maintain it at or above the
operating limits established during the performance tests."

•	(following sentence in section V.K., which appears on page 25052 of the proposed rule) "These
parameters include pH, pressure drop and liquid flow rate for wet scrubbers; and sorbent
injection or addition rate for dry scrubbers, DSI systems, and DLPS systems."

719


-------
•	(following sentence in section V.M., which appears on page 25054 of the proposed rule) "This
includes technologies to control acid gases (wet and dry scrubber technology and the use of
sorbent injection), the Hg requirements (co-benefits from other controls such as scrubbers and
FFs and Hg-specific controls such as ACI and DLPS), the non-Hg metal requirements (upgrades
and or replacements of existing particulate control devices), and other HAP emissions (GCP)."

•	(following sentence in section V.M., which appears on page 25054 of the proposed rule) "For
Hg, EPA projects that companies will comply through the collateral reductions created by other
controls (e.g., scrubber/SCR combination), ACI, or DLPS technology."

•	(In section 63.10011(b)(6)(iv), which appears on page 25114 of the proposed rule) "For a dry
scrubber, dry sorbent injection (DSI) system, or dual liquid-powder sorbent (DLPS) system, you
must establish the minimum hourly average sorbent injection or addition rate for each sorbent, as
measured during the three-run performance test and as defined in §63.10042, as your operating
limit."

•	(In section 63.10022(a)(4), which appears on page 25118 of the proposed rule) "For each
existing unit participating in the emissions averaging option that is equipped with dry sorbent
injection or dual liquid-powder sorbent injection, maintain the 3-hour average parameter values
at or below the operating limits established during the most recent performance test;"

Response to Comment 7: The agency reviewed the changes suggested by the commenter, and, apart
from adding "or other sorbent injection system" to the description of dry sorbent injection, did not make
other changes. The Agency notes that the process described by the commenter has been addressed
already in the preamble.

Comment 8: Commenter 17755 suggests that the EPA provide a definition of "operating" with regard
to section 63.10020(b), which states that the CEMS must operate at all times that the affected EGU is
operating. The commenter recommends that the definition should clarify whether operating will include
times when the unit is combusting fuel, or only include times when the unit is producing electricity, or if
operating includes when the boiler fans are being operated (i.e., ID and FD fans), and will it include
startup, shutdown, malfunction, maintenance, and/or offline periods.

Response to Comment 8: The comment is moot because rule's definition of the term boiler operating
day already describes operation as being the period when fuel is combusted at any time.

Comment 9: Commenter 17696 requests that the EPA create an explicit definition for the "maximum
normal operating load" at which performance tests would be required to be conducted under
63.10007(c). The commenter suggests that defining the term will minimize variations in implementation
and recommends that the term be defined as"90-100 % of the unit's reported maximum
load as identified in EPA's Emissions Collection and Monitoring Plan System (ECMPS) or EIA-767."

Comment 10: Commenter 17881 notes that the term "normal load" is not defined in either Part 63
subpart UUUUU or its associated appendix A. For purposes of defining normal load at which the RATA
should be operated, the commenter recommends that the provisions of 40 CFR Part 75, appendix A,
section 6.5.2.1 should be adopted in order to eliminate any potential confusion and provide needed
flexibility for infrequently operated units (i.e., peaking units), in which case the normal operating load
may vary widely.

Response to Comments 9 -10: The agency reviewed the commenters' concerns, and the rule has been
revised so that for purposes of this rule a normal load shall have the meaning given in section 6.5.2.1 of
appendix A to Part 75.

720


-------
Comment 11: Commenter 17881 recommends that the EPA develop a definition for "long-term cold
storage" to clarify the EPA's intent on reporting for those units placed into long tern cold storage
(LTCS). The commenter states that if the EPA intends to allow discontinuation, similar to the associated
provisions in 40 CFR Part 75, the proposed appendix A should also be revised to include relevant
supporting infrastructure (i.e., a definition for LTCS, provisions in subpart UUUUU to clarify the
reporting obligation for such units etc.).

Response to Comment 11: The rule has not been changed because agency finds the comment not
relevant, since an inoperable EGU would have no emissions to report.

Comment 12: Commenter 17878 recommends that ambiguities regarding measurement of "Btus"
should be resolved by explicitly defining "British thermal unit" or "Btu" as the gross calorific value (i.e.,
the higher heating value). This will eliminate the possibility of confusion with the net calorific value
(i.e., the lower heating value). Disputes and misunderstandings may result if it is unclear to which basis,
gross or net calorific value, the rule refers.

Response to Comment 12: The agency disagrees with the commenter's assertion that the rule is
ambiguous, for the Agency and its rules have consistently used the higher heating value, i.e., the gross
calorific value, in association with a British thermal unit (Btu). No changes to the rule have been made.

721


-------
8C - Rule: Corrections to tables

Commenters: 17174, 17191, 17197, 17675, 17677, 17691, 17716, 17718, 17721, 17725, 17775, 17800,
17801, 17808, 17821, 17881, 17886, 17909, 17913, 17915, 18034, 18498, 18539

Comment 1: Several commenters request that the EPA look at inconsistencies within the tables
contained in the proposed rule. Most of the comments pertained to specific tables, however Commenter
17677 states that the tables are confusing because they appear to be summarizing too much information
in one table and are not pollutant category oriented, e.g., Dioxin/Furans, Non-Hg Metals, Mercury, Acid
Gases. The commenter suggests that clarity may be achieved by creating more tables and separating by
fuel types as most all facilities will be > 8,300 Btu/lb, then by unit types under each fuel section, then by
the pollutant groups. The commenter recommends that the EPA expand the last column "Using these
requirements as appropriate" to include specifics rather than statements which may be too general to
provide clarity. Additionally, listing a reference method for each test and then including the exceptions
to that reference method, as done in some rows, is recommended.

Response to Comment 1: The agency reviewed the concerns of this commenter, as well as other
commenters, and the rule tables have been revised for clarity.

Specific comments to tables have been organized by Table, below.

1.	Table 1:

Comment 2: Commenterl7174 recommends that Table 1 should state that total particulate matter
(filterable and condensable) is the pollutant being regulated rather than "particulate matter" in order to
clearly agree with the preamble.

Comment 3: Commenters 17801 and 17821 note that Footnotes 1, 2, 3, and 4 from Table 1 (p. 25125-
25126) are missing so the readers cannot confirm or fully assess the intent.

Comment 4: Commenter 17909 questions whether the agency intended to insert OR vs. AND between
choices for compliance based on total PM, total non-Hg metals, and individual HAP metals. The
commenter recommends that the EPA clarify Table 1 and correct the text of the preamble and the rule
accordingly. The commenter further states that if Table 1 is correct as written, the preamble and the rule
should be updated to match and that tests that are not compared to a standard are unnecessary and should
be deleted from the description of the initial and ongoing testing requirements. If Table 1 is not correct
the commenter requests a detailed explanation and guidance as to how to run initial and subsequent
stack tests, how to assess compliance of those results, and how to determine the "operational limit" for
continuous compliance should be issued by the EPA. The commenter also requests that this portion of
the proposed rule should be re-written and re-published for comment.

Response to Comments 2-4: Based in part on the comments received and the Agency's review of
those comments, the table now identifies the type of particulate matter in the emissions limit, contains
all footnotes, and has comparable rule text. The Agency sees no need for reproposal because its
revisions follow from these and other comments and are a logical outgrowth of the proposal and
suggested revisions.

2.	Table 2:

722


-------
Comment 5: Commenterl7191 requests that the EPA revise Subpart UUUUUU of Part 63-Emission
Limits for Existing EGUs, Table 2, Row 3 regarding IGCC units to include the S02 CEMs option for
acid gas compliance in new and reconstructed IGCC units, adjusting the SO2 emission limit as
appropriate for existing units.

Comment 6: Commenter 17801 notes that Footnotes 5, 6, and 7 from Table 2 (p. 25126-25128) are
missing so the reader cannot confirm or fully assess the intent.

Comment 7: Commenter 17909 questions whether the agency intended to insert OR vs. AND between
choices for compliance based on total PM, total non-Hg metals, and individual HAP metals. The
commenter states that no indication is given as to how (or even if) results of tests to determine total
particulate AND total non-Hg HAP metals AND individual HAP metals, as discussed in the preamble of
the rule (p.25029) and the rule itself (p. 25103),are to be compared to the standards in Table 2. If Table 2
is correct, a source could comply by running tests to determine total particulate (if results are less than
0.030 lb/MMBTU, the source passes initial certification), and no metals data would be needed at all OR
a source could determine total metals and no total particulate or individual metals data would be needed,
etc. Subsequently, the commenter emailed the EPA. The EPA's email stated that both particulate AND
metals testing are indeed required during the initial certification testing and in subsequent tests required
every 5 years. No indication was given as to how to determine compliance of the results, however the
EPA did state that a relationship or correlation between filterable particulate and total particulate would
be developed. The EPA also stated a relationship or correlation between total particulate and total metals
emissions could be developed. The commenter requests clarification on whether this means that one
would check total metals test results against the Table 2 standard (pass/fail) and check the total
particulate results (pass/fail), then try to correlate those results with a Method 5 filterable test result and
a PM CEMS reading. That PM CEMS reading in lb/MMBTU then would be the "operational limit" to
be calculated on a 30 boiler day operating average to determine compliance. The commenter
recommends that EPA clarify Table 2.

The commenter further recommends that EPA clarify Table 2 and correct the text of the preamble and
the rule accordingly. The commenter states that if Table 2 is correct as written, the preamble and the rule
should be updated to match and that tests that are not compared to a standard are unnecessary and should
be deleted from the description of the initial and ongoing testing requirements. If Table 2 is not correct
the commenter requests a detailed explanation and guidance as to how to run initial and subsequent
stack tests, how to assess compliance of those results and how to determine the "operational limit" for
continuous compliance should be issued by the EPA. The commenter also requests that this portion of
the proposed rule should be re-written and re-published for comment.

Response to Comments 5-7: The agency reviewed all comments and revised the rule to allow an SO2
alternative emissions limit for new IGCC EGUs that employ flue gas desulfurization technology, to
include all footnotes, and to allow the EGU owner or operator to choose one of a number of non-
mercury HAP metals alternative emissions limits and demonstrate compliance with the selected limit
only. As mentioned elsewhere, the agency finds no need to repropose the rule.

3. Table 3:

Comment 8: Commenter 17881 suggests that the current reference of 63.10005, which relates to the
initial compliance requirements is very broad, and a more appropriate citation would be 63.10005(f).

Comment 9: Commenters 17174 and 17691 state that the reference provided in Table 3

723


-------
regarding annual performance tests for work practice standards, section 63.10005, does not contain any
reference for tune-up work practice performance tests to be conducted annually. However, section
63.10006(r) contains language regarding meeting applicable tune-up work practice standards. The
commenters request that the proper citation and period testing be provided in Table 3. Furthermore,
Commenter 17691 adds that section 63.10006(r) states that sources required to meet an applicable tune-
up work practice standard must conduct a performance tune-up according to 63.10007, but that section
speaks only of performance testing, not tune-ups. The commenter requests that each section be reviewed
for clarity.

Comment 10: Several commenters (17716, 18498, 17725) recommend that the phrase "performance
test" in Table 3 be replaced with "boiler tune-up" to avoid confusion and be consistent with the language
in 63.10005(f).

Response to Comments 8 -10: The agency reviewed the commenters' concerns, and Table 3 in the rule
has been revised to better describe the work practice standards. As the performance test for some units
subject to a work practice standard is a tune-up, no change to the rule language was made.

4. Table 4:

Comment 11: Commenter 17197 provides the following recommendations for Table 4:

•	If compliance with the applicable Table 1 and 2 emissions limits is being demonstrated using Hg
CEMS, SO2 CEMS, and PM CEMS, there is no need to also establish operation limits for the
EGU's control equipment. Therefore, Table 4 is unnecessary, but should at least be modified to
state that Hg, acid gas and total PM compliance can be demonstrated using CEMS. Section
63.9991 (a) should also be modified to read "7ow must meet the requirement in paragraph (a)(1)
and or (2) of this section. "

•	The commenter recommends that the rule should clearly state that: If continuous compliance is
demonstrated with PM CEMS, a fabric filter bag leak detection system (BLDS) operating limit is
not applicable. Table 4 contains both PM CEMS and Fabric Filter Control "Operating Limits"
and the fabric filter operating limit requirement to install and operate a BLDS could be
interpreted as additive to the PM CEMS requirement.

•	The commenter suggests that operating limit for Dry Scrubber DSI and carbon injection control
in Table 4 may only be intended for EGUs that demonstrate Low Emitting EGU status for Hg
and qualify for alternate monitoring. The operating limit requires that the sorbent or carbon
injection rate be maintained at or above the lowest 1-hour average sorbent flow rate measured
during the most recent performance test demonstrating compliance with the Hg emissions
limitation. However, since the Hg CEMS performance test is the initial 30-day rolling average
period, the minimum 1-hour injection rate could be zero. Furthermore, the commenter states that
if continuous compliance is demonstrated with Hg CEMS or sorbent trap monitoring, section
63.9991 should clearly state that establishing operating limits for dry scrubber, DSI, or carbon
injection control is not required.

Comment 12: Commenter 17721 states that Table 4 should be revised as follows:

"Dry scrubber, DSI, or DLPS injection control: Maintain the sorbent injection or addition
rate at or above the lowest 1-hour average sorbent flow rate measured during the most
recent performance test demonstrating compliance with the Hg emissions limitation."

724


-------
Comment 13: Commentersl7174and 17775 suggest that the intended reference provided in Table 4
regarding fuel analysis procedures to demonstrate compliance with the applicable limits may be
63.10011(c) and not 63.10011(d). No provisions for fuel analysis compliance are found in the reference.
Similarly, Commenter 17881 states that the Fuel Analysis requirement should reference 63.1001 l(c)(3-
6) as applicable.

Comment 14: Commenter 17675 recommends that the language in Table 4 be revised to allow
flexibility when implementing the parametric monitoring requirements for EGUs. The commenter points
out that parameters determined at the maximum operating rate(s) as required by the language in the
proposed standard will not be attainable over all levels of operation without the flexibility to set ranges
of parameters that vary with operating levels, heat input, or electrical output of the EGU historical data
and multiple tests to be utilized when establishing parameter ranges for operating parameters, consistent
with 63.864(j) (Part 63 subpart MM).

The commenter also indicates that paragraph 2.a (operating limits for acid gas scrubbers) contains
clarity issues and a possible error. The paragraph is unclear if the requirements to "maintain the pH at or
above the lowest 1-hour average pressure drop across the wet scrubber" are intended to apply to pH and
liquid flow rate; pressure drop and liquid flow rate; or pH, pressure drop, and liquid flow rate. However,
if the EPA intended to regulate pressure drop, regulation/monitoring should be removed from the
requirements for acid gas scrubbers that utilize spray absorption because there is no way to adjust or
control the pressure drop, nor does it have any relationship to the acid gas scrubbing efficiency of a
spray absorber.

Comment 15: Commenter 17821 notes that in Table 4, pH is incorrectly referenced "2. Wet acid gas
scrubbers... a. Maintain the pH at or above the lowest 1-hour average pressure drop." Also, pH is
omitted from the description on page 25,112 of how to monitor various operating parameters.

Comment 16: Commenter 17808 notes inconsistencies between the operating limits specified in Table 4
and Table 7. Page 25030 of the preamble states that the operating limits for an ESP would be based on
the "minimum hourly values" for each test run; however, Table 7 requires sources to "collect secondary
voltage and current... every 15 minutes during the entire each individual test run in the three-run
performance test by computing the average of all the 15-minute readings taken during each test run."

Comment 17: Commenter 17881 states that the requirement that the injection rate shall be maintained
at or above the lowest 1-hr average is in conflict with the definition of minimum sorbent injection rate
provided in 63.10042, which states that the minimum rate means 90% of the test average sorbent
injection rate for each sorbent measured during the most recent performance test.

Commenter 17881 also states that the Performance Testing requirement should specify that operating
load must be monitored and recorded.

Response to Comments 11-17: The commenters' concerns are moot, for with the exception of a new
option for meeting the non-Hg HAP metals emissions requirements through the use of a PM CPMS, the
rule no longer requires operating parameters for pollutants.

5. Table 5:

Comment 18: Commenter 17886 states that Table 5 specifies a Method 5 front half temperature of 320
degrees F and should instead reference Method 5B to be consistent with any standard.

725


-------
Commenter 17886 also states that Table 5 specifies quantification of HF, but should not since there are
no limits given for HF.

Response to Comment 18: As explained elsewhere, the agency disagrees with the commenter, and the
rule continues to require the use of Method 5, not 5B. The rule continues to contain an HF emissions
limit for liquid oil-fired units, so the comment is moot.

Comment 19: Commenter 18498 states that Table 5 should be revised to include the following
reference methods as an option for compliance demonstration:

•	EPA Method 2H and Conditional Test Method 41 (wall effects adjustment for flow)

•	EPA Method 26A (HC1- option for dry stacks)

.	EPA Method 320 (HC1- FTIR option)

•	EPA Method 5B, 17 (total, filterable PM)

Commenter states that the table should indicate that Method 2 (or equivalent) need only be used if
necessary to calculate output-based emissions.

Response to Comment 19: The agency reviewed the commenter's concerns, and the rule is revised to
include Method 2H, 26A, and 320; other Methods did not meet this rule's criteria and remain excluded.

Comment 20: Several commenters (17716, 17725, 18498) point out that the reference provided for
Table 5 (Appendix A) does not address monitoring certification and ongoing monitoring requirements
for PM and HC1 CEMS.

Response to Comment 20: The agency reviewed the commenter's concern, and the table now has
appropriate monitoring certification and monitoring requirements.

Comment 21: Commenter 18034 states that the reference footnote 9 in Table 5 (section 63.10005(1))
does not address calculating emissions during startup and shutdown operations.

Response to Comment 21: The comment is moot because rule now requires work practice standards,
not adherence to emissions limits, during periods of startup or shutdown.

Comment 22: Several commenters (17716, 17725, 18498) note that for the SO2 CEMS (Item 5) in the
"using" column for Item a, the table should include the alternative to use Part 75 requirements for
"installation," "operate," and "maintain CEMS." See Section 63.10010(e). Also, the table refers to
Sections 4.1.3 and 5.3 of Appendix A to the subpart, but SO2 is never mentioned in Appendix A.

Response to Comment 22: The agency has reviewed the comments, and the table now references Part
75 requirements and contains correct references.

Comment 23: Several commenters (17675, 17718, 17881) state that section 63.10010(h) discusses
installing CPMS as specified in Table 5 of this subpart. This section should instead refer to Table 4
which contains operational parameters rather than Table 5 which contains performance testing
requirements. If the section is correctly referencing Table 5, then it is unclear what CPMS are required.

Response to Comment 23: The comment is moot, as table 6 now contains operational parameter
instructions for those EGU owners or operators who choose to use PM CPMS.

726


-------
Comment 24: Commenters 18498 and 17725 recommend that the EPA add the text below to Table 5, as
applicable:

"Alternatively, for an affected source that is also subject to the 02or CO2 monitoring
requirements of Part 75 of this chapter, the owner or operator may install, certify,
maintain, operate and quality assure the data from an 02or CO2CEMS according to Part
75 of this chapter in lieu of the procedures in paragraphs b(l) through b(3) of this
section."

Commenter 18498 also recommends Section 60.10010(b) should reference Part 75 in lieu of the
alternate requirements specified in Appendix A to Subpart UUUUU with regard the 02and CO2 CEMS
requirements.

Response to Comment 24: The agency reviewed the commenters' concerns, and the rule now
references Part 75 requirements in both table 5 and in rule text.

Comment 25: Commenter 17881 states that exhaust flow and moisture should only need to be
determined if you are complying with the lb/MWh limit. The O2/CO2 levels should only need to be
determined if you are complying with the lb/MMBtu standard. The commenter recommends that the
EPA clarify the language in Table 5 in order to prevent the collection of data which is not needed to
assess compliance with the chosen emission limit form (i.e., heat input or electrical output basis).

Response to Comment 25: The agency has reviewed the commenter's concern, but disagrees with the
concern. The table is not changed, for an owner or operator need not provide the exhaust flow or
moisture levels if his or her EGU complies with an electrical output based standard.

Comment 26: Commenters 18498 and 17725 request clarity regarding performance specification for
HCI. Table 5 lists Performance Specification 6 but it does not apply since it is for systems that measure
pollutant emissions in units of mass per unit of time. The EPA has developed no performance
specification for non-FTIR based HCI CEMS. The commenters state that the lack of a performance
specification for HCI (coupled with limited utility HCI operating experience, particularly for compliance
near the detection limits of the systems) makes it difficult to provide meaningful comments.

Response to Comment 26: The agency disagrees with the commenter, for an FTIR CEMS, subject to
PS 15, could be used for HCI CEMS. Should an owner or operator of an EGU not choose to use an FTIR
CEMS to demonstrate compliance with HCI emissions, he or she could use quarterly emissions testing
or wait and use non-FTIR HCI CEMS using the separate HCI CEMS performance specifications under
development but expected to be promulgated before the rule's compliance date.

Comment 27: Commenter 17881 states that bullet c. should read: "Determine oxygen OR carbon
dioxide concentrations of the stack."

Response to Comment 27: This change to the rule has been made.

Comment 28: Commenter 17881 states that the reference to a 30-day rolling average is not appropriate.
Per 63.10005(k)(2), a 28-30 day integrated average value is being established, not a 30-day rolling
average.

Response to Comment 28: The comment is moot because rule now requires a 30-day integrated

727


-------
average value.

6.	Table 6:

Comment 29: Commenter 17881 states that Table 6, which provides the fuel analysis requirements,
does not address gaseous fuels at all even though gaseous fuel may be co-fired (for purposes other than
startup and flame stabilization) with one or more fossil fuels which are regulated in the proposed EGU
MACT, particularly liquid oils.

Commenter 17881 states that in the requirements for HF, there is a typo in bullet f.; it should read
"measure fluorine concentration in fuel sample" instead of chlorine.

Response to Comment 29: The comment is moot, for the rule no longer requires fuel analysis for
pollutants.

7.	Table 7:

Comment 30: Several commenters (17174, 17808, 17881) state that the reference provided in the table
regarding emission operating limits through fuel analysis should be 63.10011(b) as opposed to
63.10011(c).

Comment 31: Commenters 17775 and 17808 state that the table only lists the operating limits for ESPs
for units that operate wet scrubbers, therefore conflicting with other provisions, including proposed
section 63.1001 l(b)(6)(iii). The table does not include the operating parameters for a unit with an ESP,
but no wet scrubber.

Comment 32: Commenter 17721 states that Table 7 should be revised to add operating limits for
sources using dry scrubbers, DSI, or DLPS to comply with PM, Hg, or non-Hg HAP metals emission
limits as follows:

1 Particulate matter (PM), mercury (Hg), or other non-Hg HAP metals:

d. Dry scrubber, DSI, or DLPS operating parameters

i. Establish a site specific minimum sorbent injection or addition rate operating limit according to
§63.10011(c). If different Hg sorbents are used during the Hg performance test, the average value for
each sorbent becomes the site-specific operating limit for that sorbent.

(1) Data from the sorbent injection or addition rate monitors and Hg performance test.

(a)	You must collect sorbent injection or addition rate data every 15 minutes during the entire period
of the performance tests;

(b)	Determine the average hourly sorbent injection or addition rates of the three test run averages
measured during the performance test.

Comment 33: Commenter 17721 states that Table 7 should be revised to add operating limits for
sources using dry scrubbers, DSI, or DLPS to comply with HC1 or HF emission limits as follows:

728


-------
2. "Hydrogen Chloride (HCL) or hydrogen fluoride (HF)

(b)	Dry scrubber, DSI, or DLPS operating parameters

(1) Establish a site specific minimum sorbent injection or addition rate operating limit according to
§63.10011

(c)	If different Hg sorbents are used during the Hg performance test, the average value for each sorbent
becomes the site-specific operating limit for that sorbent.

(1) Data from the sorbent injection or addition rate monitors and Hg performance test.

(a)	You must collect sorbent injection or addition rate data every 15 minutes during the entire
period of the performance tests;

(b)	Determine the average hourly sorbent injection or addition rates of the three test run averages
measured during the performance test."

Response to Comments 30 - 33: The comments are moot, for the rule no longer requires establishment
of operating parameters for pollutant control devices.

8. Table 8:

Comment 34: Several commenters (17716, 17725, 17775, 18498) point out that Table 8 erroneously
refers to "QA Procedure 5" for the PM CEMS QA/QC requirements and should refer to "Procedure 2"
instead.

Comment 35: Commenter 17881 states that the references in the "you must" column should be re-
checked, as there are several that are incorrect. For example, 7.a. should be QA Procedure 2, not 5, and
7.b. should be "30 boiler operating day average mg/dscm values" rather than the current "30 boiler
operating mg/dscm values."

Comment 36: Commenters 17775 and 17808 state that references to section 63.1011(c) in Table 8 may
be intended to reference section 63.1011(b) instead.

Comment 37: Several commenters (17800, 17725, 18498) state that the method for calculating 30
rolling averages in Table 8 is not consistent with the method in section §63.10010(g). Table 8 states that
the source should convert "hourly emissions concentrations to 30 boiler operating mg/dscm values,"
which suggests that compliance is assess based on the average of 30 individual daily values. However,
section 63.10010(g)(5) states that 30-day rolling average is calculated as "the average of all of the
hourly particulate emissions data for the preceding 30 boiler operating days." Commenter 17800
recommends that the EPA consider changing this averaging time to a 12-month rolling average
consistent with the Illinois MPS rule to help capture the variability associated with the operation of an
EGU. If the 30-day average is not updated to be consistent with the Illinois MPS rule, the commenter
suggests that the methodology in Table 8 be updated to be consistent with the other sections.

Comment 38: Commenters 18498 and 17725 note that Table 8 requires CPMS data to be reduced to 12-
hour block averages; however, this requirement is not specified in section 63.10010(h).

729


-------
Comment 39: Commenter 18539 states that Table 8 refers to opacity operating limits however it
appears that no other references to opacity operating limits exist. The commenter requests that the EPA
clarify whether the intent is to allow for opacity operating limits exist in the proposed rule.

Comment 40: Commenter 17721 states that Table 8 should be revised as follows:

"4. Dry scrubber, DSI sorbent, DLPS sorbent, or carbon injection rate

a.	Collecting the sorbent or carbon injection rate monitoring system data from the dry scrubber, DSI,
or DLPS according to §63.10010 and §63.10020; and

b.	Reducing the data to 12-hour block averages; and

c.	Maintaining the 12-hour average sorbent or carbon injection rate at or above the operating limit
established during the performance test according to §63.10011(c)."

Response to Comments 34 - 40: The agency finds the comments are moot, as table 8 has been revised
to remove all requirements associated with developing and maintaining operating limits for pollution
control devices.

9.	Table 9:

Comment 41: Several commenters (17913, 17915, 17174) request that the reference to startup,
shutdown, and malfunction (SSM) plans in Table 9 should be removed because it conflicts with the text
in Table 10 and the preamble that states SSM plans are not required.

Comment 42: Commenter 17775 indicates that the Table 9 should be evaluated for the following
inconsistencies:

•	The error, "information required in §63.10031(c)(1) through (11) through (11)," should be
addressed. In addition, the EPA should review the text and consider referencing §63.10031(c)
subsection (12) as well. Commenter 17881 notes this inconsistency as well.

•	The table specifically requires submission of a startup, shutdown, and malfunction report containing
the information in §63.10(d)(5)(i) at l.d and 2, however, Table 10 states that §63.10(d)(5) does not
apply. The EPA should address the inconsistency and correctly identify applicable reporting
requirements.

Response to Comments 41 - 42: The Agency has reviewed the commenters' concerns and revised the
table by removing requirements to develop and submit a startup, shutdown, or malfunction plan and
corrected the text cite language, as suggested by the commenter.

10.	TablelO:

Comment 43: Commenter 17775 states that section 63.1(a)(4)(i) requires each standard to "identify
explicitly whether each provision in this subpart A is or is not included" and that the EPA proposes to
address applicability in Table 10. The commenter provides the following instances of inconsistencies in
Table 10 with respect to applicability:

• EPA identifies §63.6(h)(2)-(9), and §63.9(f), and (g)(2) as applicable. Proposed §63.10030(a)

730


-------
also requires compliance with §63.9(f). These provisions pertain solely to compliance with
opacity and visible emission standards. Since the proposed rule does not include any applicable
opacity or visible emission standards, these portions of the general provision do not apply and
Table 10 should be revised accordingly.

•	EPA fails to identify whether §63.6(e)(l)(iii) applies.

•	EPA fails to identify whether §63.8(a)(1), (2), and (4), (b), (c)(2), (4)(i), (5), (6), (8), (d)(1),
(d)(2), (f), or (g) apply. Sections (c)(l)(ii), (3), (4)(ii), (7)(i), (8), and (d) are referenced in
proposed §63.10000(d)(4) and §63.8(e) is referenced in proposed §63.10030(a), but not in Table
10. Some of these provisions apply solely to opacity monitoring, and should not apply, but the
EPA must state whether or not they are included. The EPA should provide that CEMS meeting
the requirements of Part 75 are exempt from the "performance evaluation" test plan and notices
in §63.8(e). The EPA also should make clear that those requirements do not apply to "calibration
error testing," since "performance evaluation" is defined in §63.2 to include both relative
accuracy testing and calibration error testing.

•	EPA fails to identify whether §63.10(b)(2)(x)-(xiii) apply.

•	EPA identifies §63.10(c) as applicable in its entirely, but later in the table separates out

§63.10(c)(7) and (8) as applicable and §63.10(c)(10), (11), and (15) as not applicable. The EPA
also cites §63.10(c) in its entirety as requirements of the site-specific monitoring plan in
proposed §63.10000(d)(7). Note also that §63.10(c)(7) and (8), which specify recordkeeping for
sources with continuous monitoring requirements, require reporting of "excess emissions" "as
defined in the relevant standard(s), that occur during startups, shutdowns, and malfunctions of
the affected source" and those that occur "during periods other than startups, shutdowns, and
malfunctions." Proposed subpart UUUUU does not define "excess emissions" for any standard
and does not exempt periods of startup, shutdown, or malfunction.

•	In determining whether the recordkeeping requirements in §63.10(b) and (c) apply, the EPA
must ensure its compliance with the PRA. Under 5 C.F.R. §1320.5(d)(2), the EPA cannot require
retention of such records for more than 3 years, unless the agency demonstrates in its OMB
submission that that a longer retention period is necessary to "satisfy statutory requirements or
other substantial need."

•	EPA fails to identify whether § 63.10(d)(3)-(4) are applicable.

Response to Comment 43: The agency reviewed the commenter's concerns, and the rule and table have

been revised, where appropriate, to remove inconsistencies.

Appendix A:

Comment 44: Commenter 17775 points out the following inconsistencies in Appendix A:

•	Appendix A §4.1.1.3 incorrectly refers to Table A-2 instead of Table A-l.

•	The conversion factors used in Appendix A §6.2.1.2, Equation A-2 and Equation A-3 should be the

consistent. Appendix A §6.2.1.2 includes a factor of 6.24x10-11 to convert Hg concentration from

[j,g/scm to lb/scf whereas Equations A-2 and A-3 use a constant of 6.236x10-11.

•	Appendix A says that quarterly reports must include the information in §§7.1.2-7.1.19, however

§§7.1.11-7.1.19 do not exist.

Comment 45: Commenter 17881 suggests that the following changes be made regarding Hg Monitoring

Provisions in order to harmonize Appendix A of the EGU MACT with the requirements of 40 CFR Part

75, as most (if not all) units subject to the EGU MACT will also be subject to 40 CFR Part 75 emissions

monitoring:

731


-------
•	Table A-2, Flow Rate RATA Specifications: "40 CFR Part 75, App. A, Section 3.3.4 also provides
an alternate performance specification of not > 2.0 feet per second (FPS) when the average RM
value is < 10.0 FPS."

•	Table A-3, Daily Calibration Error Test: The first bullet should read "use zero gas and either a mid-
or high- level gas," as daily calibration error tests are generally conducted using a zero and upscale
calibration gas.

•	Table A-4, Daily Calibration Error Test for 02 or C02: The first bullet should read "use zero gas
and either a mid- or high- level gas," as daily calibration error tests are generally conducted using a
zero and upscale calibration gas.

•	Table A-4, Daily Interference Check for Flow Rate: "40 CFR Part 75, App. B, Section 2.1.4(a)
allows < 6.0% of the calibration span."

•	Table A-4, Flow Rate RATA: "The 40 CFR Part 75 App. B, Section 2.3.1.2(d) alternate
specification for flow monitors of ± 1.5 FPS when the average RM value is < 10 FPS should also be
allowed."

Commenter 17881 also asks if the EPA intends moisture monitoring systems consisting of wet and dry
O2 monitoring systems to be exempt from any sort of daily calibration error test requirement. For such
moisture monitoring systems, the commenter states that 40 CFR Part 75 generally requires those same
on-going quality assurance tests as are required for O2 diluent monitors however Appendix A of the
proposed EGU MACT only appears to require a RATA test.

Response to Comments 44 and 45: The reference to Table A-2 in section 4.1.1.3 of Appendix A was a
typographical error and has been corrected. The conversion factors in Equations A-2 and A-3 have been
made consistent; both factors are now 6.24 x 10E-11. The reference in the quarterly reporting section of
Appendix A to section 7.1.19 was a typographical error and has been corrected.

The EPA has not incorporated the commenter's suggestion to harmonize the information in Tables A-2
and A-4 with Part 75, because Tables 2 and 4 have been deleted from Appendix A. The agency has
decided against reproducing part 75 certification and QA specifications in Appendix A for the flow rate,
diluent gas, and moisture monitoring systems that are used to convert Hg concentrations to units of the
standard. Instead, section 3.2.3 of Appendix A simply states that these monitoring systems must be
certified, operated, maintained, and quality-assured according to 40 CFR part 75. The EPA has
incorporated the edit to Table A-3 (which has been renumbered as Table A-2) suggested by the
commenter, i.e., that the daily calibration error tests of the Hg CEMS must be done with a zero gas and
either a mid-level or high-level calibration gas. Finally, moisture monitoring systems consisting of wet
and dry O2 analyzers are not exempted from daily calibration error tests. The O2 monitors in these
systems must meet the daily calibration requirements of part 75.

732


-------
8D - Rule: Language

Commenters: 16513, 17174, 17191, 17254, 17386, 17622, 17623, 17655, 17656, 17675, 17677, 17681,
17689, 17691, 17696, 17705, 17711, 17714, 17716, 17718, 17721, 17725, 17730, 17731, 17752, 17756,
17758, 17775, 17781, 17795, 17796, 17800, 17801, 17808, 17821, 17843, 17848, 17870, 17881, 17909,
17912, 18014, 18027, 18034, 18037, 18498, 19120, 19536/19537/19538, 18023

1.	Clarifications.

Comment 1: Several commenters request that the language of the rule be updated to clearly state the
requirements for each category, subcategory, pollutant and compliance option used at facilities.
Commenter 18034 requests that the EPA clarify how to determine emission rates during a startup,
shutdown, or malfunction situation.

Response to Comment 1: We believe that the final rule language is clear.

Comment 2: Multiple commenters (17677, 17730, 17758, 17909, 17912) request that the preamble
should be updated and clarified to be consistent with the rule language. For example, Commenter 17912
notes that the preamble to the proposed rule states the EPA's intent to exclude stationary combustion
turbines from this rule. However, the proposed rule text excludes only those stationary combustion
turbines located at major sources. The commenter requests that the EPA revise the rule text to confirm
its intent to exclude all stationary combustion turbines, including those located at minor source facilities.

Response to Comment 2: We do not believe that the regulatory language distinguishes between major
and area source facilities as the term "major source" is not used.

Comment 3: Commenter 17656 urges the EPA to make clear precisely what requirements apply to each
category/subcategories and the different options for compliance that are available. Commenters 17677
and 17730 both oppose leaving such clarification for follow-on guidance.

Response to Comment 3: We believe that the final rule clearly presents the compliance options as
requested by commenters.

Comment 4: Commenter 17730 appreciates the variety of options that the EPA has provided for sources
to demonstrate ongoing compliance, but states that several of the options will require clarification in
order for facilities to understand the options, applicability, and to demonstrate compliance. The
commenter recommends that the EPA revise the proposal to make clear exactly what requirements and
rationale apply to each compliance option. The commenter points out that the EPA has the opportunity
to electronically publish each of the different subcategories and the different options in a clear, direct,
and plain language fashion with a limited amount of references to other subsections, or mentions of "as
applicable. The EPA has substantively failed to provide a clear and readily understandable set of
requirements for sources in this proposed rulemaking.

Response to Comment 4: The agency believes that the final rule provides a clear and readily
understandable set of requirements, and the rule contains clarifications where appropriate.

2.	CEMS comments.

Comment 5: Multiple commenters (17623, 17655, 17716, 17681, 17800, 17821 and several others)

733


-------
request that the EPA review and update the language regarding CEMS, performance testing and
operating limits.

Response to Comment 5: As mentioned earlier, the agency has reviewed the commenters' concerns
and revised the rule where appropriate.

Comment 6: Commenter 17716 states that the proposed rule should be clarified to explicitly exempt
sources using a CEMS for compliance for a particular pollutant from all fuel sampling requirements for
that pollutant. The commenter states that the fuel sampling requirements apply only to those units that
demonstrate compliance through performance (i.e., stack) testing for a particular pollutant, but
§63.10005(a) states that "performance testing" may also consist of CEMS operating data, thereby
creating ambiguity about whether units using a CEMS for compliance must also meet the fuel sampling
requirements.

Comment 7: Commenters 18498 and 17725 recommend that the EPA revise §63.10007 to indicate that
the fuel sampling and operating parameter limits are not required when the applicable HAP (or
surrogates) are monitored using a CEMS.

Response to Comments 6-7: The agency agrees with the commenters, and the rule has been revised to
not require fuel sampling of pollutants where CEMS are used for compliance purposes.

Comment 8: Commenter 17718 states that it is not clear that installing and operating CEMS for the
regulated HAP and surrogates will relieve a source of the burden of also monitoring compliance with
operating limits on control equipment based on a performance stack test. The commenter recommends
that the EPA require no proof of compliance beyond a properly calibrated and installed CEMS, and that
the EPA revise both the language and tables in the rule to clarify its intent as it relates to CEMS used for
demonstrating compliance.

Comment 9: Several commenters (17655, 17696, 17716) state that the language regarding performance
testing and compliance is unclear and should be revised so that facilities can clearly understand and
follow regulations. Commenter 17655 specifically notes that Sections §63.10005(a), §63.10011(a), and
§63.10011(b) are difficult to interpret. For example, it is unclear whether facilities using CEMS are also
required to track performance parameters to show compliance. The commenter requests that the EPA
use consistent and clear language to enumerate the requirements for facilities with and without CEMS.

Response to Comments 8-9: The comments are moot because rule no longer requires emissions
control device operating parameters or limits when CEMS are used for compliance purposes.

Comment 10: Commenter 17821 states that the best method of determining initial compliance is with
the applicable reference method. Reference methods are used to certify the CEMS on a source. The
commenter recommends that the EPA specifically state in the rule that the use of Reference Methods are
required to demonstrate initial compliance with the emission limitations in this rule.

Response to Comment 10: The methods suitable for conducting performance tests for this rule, or any
rule, are defined in large part by specified averaging time. In many cases, this final rule clarifies that the
averaging time for initial and periodic compliance testing is the result of three relatively short term
performance test runs and through the use of manually operated test methods found in Appendix A of 40
CFR part 60 or 63. This approach to conducting initial and periodic performance tests applies to metal
HAPs, PM, and HF and HC1, and is consistent with the commenter's suggestion. On the other hand, for

734


-------
sources who opt to use Hg or SO2 CEMS in lieu of manual performance testing, the averaging time of
the rule is 30 unit operating days. This long averaging time precludes the use of manual performance test
methods on a practical basis. The final rule specifies that CEMS or sorbent trap monitoring be the
performance test method for determining initial and continuous compliance with limits expressed as a
30-day average value.

Comment 11: Commenter 17623 requests that the language in both the preamble and the rule be
updated to clarify that testing is not mandated for pollutants being controlled through a surrogate and
performance standards are not required when a CEMS is employed. In the preamble, the commenter
requests that the clause that states "and an operating limit would be established" should be removed
because it is duplicative of the CEMS requirement.

Response to Comment 11: The agency has reviewed the commenter's concern, and while the rule has
been revised so that neither emissions testing other than RATAs (or initial calibration for PM CEMS)
nor operating limits are required for EGUs that use CEMS for compliance purposes, the rule has not
been revised to exclude the requirements of performance specifications when CEMS are used for
compliance purposes.

Comment 12: Commenter 17696 states that sections 63.10000(c),(d), 63.10005, 63.10006, 63.10008,
63.10011, and 63.10021 are complex and confusing and in some cases inconsistent with the preamble
and examples in the rule. The commenter cites language on whether a coal-fired EGU without an HC1
CEMS is required to conduct monthly fuel analysis for chlorine from sections 63.10005(a), 63.10006(s),
and 76 FR 25,051 to illustrate the difficulty and contradictions contained in the rule.

Response to Comment 12: The agency has reviewed this concern, and the rule has been revised for
consistency and clarity.

Comment 13: Commenter 17796 suggests that the Hg compliance metric be succinctly stated in section
63.10010(1). The commenter states that although section 63.10010(g)(5) for PM CEMs discusses that
compliance is based upon a 30 boiler operating day rolling average emissions rate on a daily basis, the
commenter was unable to find this language for the Hg compliance limit. Section 63.10010(1) refers the
reader to Appendix A but Appendix A does not state the compliance average.

Response to Comment 13: The agency disagrees with the commenter's concern, for the rule states the
initial Hg CEMS compliance requirement at §63.10005(a)(2) and the ongoing Hg CEMS compliance
requirement at §63.10021(a).

Comment 14: Commenter 17718 notes that sections 63.10005(d)(3)-(6) state if CEMS are going to be
used for initial compliance determinations then the average hourly concentrations obtained during the
first 30-day operating period will be used "after the monitoring system is certified." The commenter
requests that the EPA clarify when the 30-day operating period begins if the systems are already
certified (e.g., current SO2 or PM CEMS being used for 40 CFR Part 75 and/or 40 CFR Part 60
monitoring programs).

Response to Comment 14: The EPA disagrees that any additional clarification is needed in the rule.
Owners or operators of new EGUs have up until 60 days after the rule appears in the Federal Register or
upon startup, whichever is later; or, for existing units, at least 3 years and 60 days after promulgation to
be in compliance with the emissions limits and standards.

735


-------
Comment 15: Commenter 17796 requests that the rule clearly state what the acceptable data capture
percentage is for Hg, HC1 and PM CEMs. The method of counting hours when a monitor is out of
service, as hours of monitor down time and using this value to determine the % of monitor availability is
consistent with NSPS requirement. For Hg, section 60.490a paragraph (p)(4) discusses the need for 75
% data capture on a monthly basis for a monitor to achieve an acceptable % monitor availability and to
be able to demonstrate consistent compliance. However, the commenter states that this whole section
will become obsolete and removed from the NSPS if the proposed changes to the NSPS and NESHAP
rules go into effect.

Response to Comment 15: The agency considered the commenter's suggestion but made no change to
the rule. The rule contains no minimum acceptable data capture percentage, for the rule at §63.10010(j)
requires data to be collected at all times an EGU is combusting fuel except for periods of monitoring
system malfunction, out-of-control operation, or quality assurance or control activities.

Comment 16: Commenter 17622 requests that the EPA clarify the statement "continuous compliance
would be determined using a PM CEMS with an operating limit established based on the filterable PM
values measured using Method 5." (76 FR 25029/2). The commenter recommends that the EPA
explicitly state if the PM CEMS would be correlated against the filterable PM fraction of total PM to
avoid confusion.

Response to Comment 16: The agency considered this and other comments, and the rule has been
revised to include a filterable PM, but not total PM, alternative emissions standard. The rule also allows
use of PM CPMS, which would have an operating limit, as well as PM CEMS, which would allow direct
measure of compliance, as compliance options.

Comment 17: Commenter 17675 further recommends that the wording in section 63.10010(a) should be
updated to clearly state that Hg CEMS and/or sorbent traps can be used for Hg monitoring, rather than
implying that both CEMS and sorbent traps are required. Similarly, Commenter 17821 recommends that
the EPA clarify the term "demonstrate initial and continuous compliance through the use on a
continuous... HC1... [and]... Hg CEMS or a sorbent trap... system" to indicate that a "certified CEMS"
must be used. The term "certified CEMS" means that all of the required testing outlined in this rule, or
in applicable portions of 40 CFR parts 60 or 75, have been completed, and that the results of the testing
met the requirements of the applicable rules. Without clarification, this section could be interpreted to
mean that certification of the CEMS is not required before using it for purposes of demonstrating
compliance.

Response to Comment 17: Although the agency appreciates the commenter's concern, no change was
made to the rule, for §63.10010(g) requires Hg CEMS or sorbent trap monitoring systems to be certified.

Comment 18: Commenter 17716 requests the following corrections and clarifications regarding CEMS:

• EPA should evaluate and revise the data reduction citations to be consistent throughout the rule.
The commenter specifically provides the following example: sections 63.10010(b)(4);
63.10010(c)(4); 63.10010(d)(4); 63.10010(e)(4); and 63.10010(g)(4) all state: "Reduce the
CEMS data as specified in section 63.8(g)(2) and (4)." However, section 6.1.1 of appendix A
relates data reduction from "Hg CEMS and (as applicable) flow rate, diluent gas, and moisture
monitoring systems to hourly averages in accordance with section 60.13(h)(2) of this chapter."
The commenter suggests that requirements in section 60.13(h)(2) are more complete since it
addresses "partial operating hours" and other data needs. Commenters 18014-A2, 17725 and

736


-------
18498 also make the same recommendation.

•	For S02 CEMS, section 63.10021(a)(13) does not include the option to use the Part 75
certification and ongoing QA/QC requirements as allowed in section 63.10010(e). Commenter
17725 also notes this issue.

•	For Hg CEMS, section 63.1002l(h)(ii) states the "Quarterly accuracy determinations and daily
calibration drift tests shall be performed in accordance with procedure 5 in Appendix F of 40
CFR Part 60." This contradicts section 63.10010(f) which references appendix A of this subpart
and should be revised to reference section 5 to appendix A. Commenter 17725 also notes this
contradiction.

Comment 19: Commenter 17881 requests the following corrections and clarifications regarding CEMS:

•	Section 63.10011(b)(6) should clarify how these requirements apply in cases where CEMs are
used for compliance.

•	The reference in section 63.1002l(a)(10)(i) is inconsistent because section 63.10010(a) does not
require the installation of O2 CEMS while section 63.10010(b) allows installation of CO2 or O2
CEMS.

•	In sections 7.1.3.5 and 7.1.4.8, the EPA requires that hourly records of % monitor availability
(PMA) be maintained for Hg CEMS and sorbent trap monitoring systems. The PMA concept is
employed in 40 CFR Part 75 in the context of determining appropriate missing data substitution
procedures. As missing data substitution will not be allowed in the context of Hg monitoring, the
commenter requests that these requirements should be deleted from proposed appendix A.

Response to Comments 18 -19: The agency has reviewed and considered each of the commenters'
suggestions. The rule now uses Part 75 data reduction and quality assurance procedures for those CEMS
also used in Part 75; Hg CEMS and sorbent traps are subject to the requirements of appendix A; HC1 or
HF CEMS are subject to the requirements of appendix B. The commenter's concern over simultaneous
control device operational parameter monitoring and CEMS is moot, for the rule no longer requires
control device operational parameter monitoring. The inconsistency between the use of C02 or 02
CEMS has been clarified; the rule now allows either type of CEMS. The rule retains the requirement to
report Hg CEMS or sorbent trap monitoring data availability; although the Agency agrees that there is
no minimum data availability requirement for these types of monitors, the Agency sees no inconsistency
between the monitoring operational and data availability reporting requirements.

Comment 20: Commenter 18498 states that as proposed, the EGU MACT Rule does not include
provisions to use the Part 75 "conditionally valid data procedures." For example, if a CEMS fails a
linearity check the CEMS remains out-of control until the successful completion of a subsequent
linearity check (reference section 60. 13(h)(2); section 63.8(g)(2) and (4)). This would require the
operator to invalidate the Part 75 conditionally valid data (for SO2, CO2, O2 or flow monitors) for the
EGU MACT recordkeeping and reporting purposes. The commenter recommends that the EPA allow
quality assured data from a CEMS certified and operated in accordance to Part 75 to be used for EGU
MACT compliance (with the exception of bias adjusted data and values derived from missing data
substitution procedures).

Response to Comment 20: As mentioned elsewhere, the rule now allows use of Part 75 procedures for
quality assurance and control activities for those monitors also used in Part 75.

Comment 21: Commenters 18498 and 17725 note that section 63.1002l(a)(10)(i) requires sources to
"continuously monitor oxygen according to §§63.10010(a) and 63.10020" if you are required to install a

737


-------
CEMS according to section 63.10010(a), however this contradicts the requirements in section
63.10010(b) which allow the use of 02 or C02. Also, the commenters note that the majority of Part 75
affected coal-fired units utilize dilution extractive CEMS which are equipped with CO2 analyzers and
CEMS cannot measure O2 as a diluent.

Comment 22: Commenter 17718 states that section 63.1002l(a)(10)(i)and(ii)) references continuously
monitoring O2, but should also reference CO2 monitoring as a diluent as an alternative. The following
specific language changes are suggested:

•	Section 63.10021 (a)(10)(i): "You must continuously monitor O2 or CO2 according to sections
63.10010(a) and 63.10020."

•	Section 62.1002l(a)(10)(ii): "Keep records of O2 or CO2 according to section 63.10032(b)."

Response to Comments 21 - 22: As mentioned elsewhere, the rule now allows O2 or CO2 CEMS to be
used.

Comment 23: Commenter 17718 states that section 63.1002l(a)(ll)(v) requires all CEMS relative
accuracy test audits (RATA) to be submitted electronically using the Electronic Reporting Tool. The
commenter requests that the EPA clarify whether this requirement is only applicable to CEMS RATAs
performed under the requirements of the rule. The commenter also requests that the EPA clarify whether
only SO2 RATAs performed for the combined purposes of 40 CFR Part 75 and this regulation would be
reported in ERT. Any annual NOx or flow monitor RATA performed for 40 CFR Part 75 requirements
would not to be reported in the ERT even though it may have been performed concurrently.

Response to Comment 23: The agency reviewed the commenter's concern and disagrees with the
commenter's assertion. The rule has not been changed, for the rule covers only those EGUs subject to
the rule's applicability. In the commenter's example, no NOx CEMS RATA data would ever need to be
reported electronically under this rule, but, as the commenter suggests, S02 CEMS RATA data from
those EGUs whose owners or operators choose to use SO2 CEMS as an alternative means of
demonstrating compliance with acid gas emissions limits would need to submit those data electronically.

3. IGCC comments.

Comment 24: Commenter 17801 recommends that the EPA provide further definition and clarification
regarding air pollution control devices (APCD) to account for upstream fuel cleanup (e.g., removal of
particulate, Hg, non-Hg metal HAPS, sulfur and/or chloride directly from the fuel stream of IGCC
units). For example, for coal-fired units with add-on APCDs, it is unclear in section 63.10006 and/or
Table 7 as to the testing program or operating limits to which IGCC would be subject. There is not an
applicable combination of CEMS/APCD described that pertains to IGCC which could allow for
emissions testing every five years for some coal-fired EGU sources instead of every other month for
those sources without add-on controls. The EPA should consider any upstream gasification/fuel clean-up
(e.g., AGR, SRU, PM scrubber) in the same way that coal-fired EGUs are credited for post-combustion
or other APCD. IGCC should not be burdened with additional testing requirements if reduced testing
programs are allowed for coal-fired units with add-on APCDs.

Response to Comment 24: The agency considered the commenter's concerns, but the rule has not been
changed. An IGCC unit can qualify for reduced frequency emissions testing under the existing rule's
LEE provisions, should an IGCC EGU owner or operator choose to use emissions testing as the means
for demonstrating compliance with the emissions limits.

738


-------
Comment 25: Commenter 17191 notes that footnote number 206 appears to preclude the use of the SO2
monitoring option for IGCC units. The commenter suggests that this may be an unintentional
consequence from carrying over language of other EGU category requirements for consistency and
requests that either the footnote be removed or modified to state, "The alternate S02 limit may not be
used if your EGU does not have some form of pre- or post-combustion desulfurization system." The
commenter suggests that the modification is necessary because IGCC units do not require "flue gas
desulfurization systems" as the sulfur is removed in the gasification phase (i.e., no post-combustion
"flue gas" desulfurization is necessary). Instead, removing the reference to "flue gas" and replacing it
with "pre- or post-combustion" accomplishes the objective of requiring desulfurization controls as a
prerequisite for S02 monitoring option without inadvertently preventing new and reconstructed IGCC
units from pursuing the SO2 alternative.

Response to Comment 25: We believe that IGCC EGUs qualify for the use of SO2 monitoring as a
surrogate for HC1. We have also clarified the definitions.

Comment 26: Commenter 17821 states that the EPA needs to revise the description and definitions of
the IGCC APCD to account for upstream fuel cleanup and/or pollution prevention measures. For
example, the technology used in IGCC units directly removes contaminants (such as particulate, Hg,
non-Hg metal HAP, sulfur, chloride) directly from the fuel stream of IGCC units. In this respect, IGCC
is more akin to a natural gas-fired combined cycle unit, since it burns a syngas, which is cleaner than the
coal combusted in a pulverized coal unit. The EPA should reflect that IGCCs use upstream
gasification/fuel clean-up (for example, AGR, SRU, PM scrubber) in the same way that coal-fired EGUs
are credited for post-combustion or other air pollution control equipment such as SCR, ESP, and FGD. It
makes no sense for IGCC to have additional testing burdens if reduced testing programs are allowed for
coal-fired units with APCD. The EPA recognizes that an IGCC unit is a distinct type of electric
generating unit by proposing a separate subcategory for IGCC units. The EPA needs to further
acknowledge the process differences between IGCC units and PC units by providing clarification that
for purposes of this MACT the affected facility is the combustion turbines and any emission limitations
apply to the heat recovery steam generator HRSG stack. Commenter recommends that the EPA needs to
provide further clarification that all upstream fuel clean-up in the IGCC process qualifies as control
equipment, thereby not putting any additional testing burdens on IGCC units when reduced testing is
allowed for coal-fired units with add-on pollution control equipment.

Response to Comment 26: As mentioned elsewhere, the agency considered the commenters' concerns,
but the rule has not been changed. An IGCC unit can qualify for reduced frequency emissions testing
under the existing rule's LEE provisions, should an IGCC EGU owner or operator choose to use
emissions testing as the means for demonstrating compliance with the emissions limits.

Comment 27: Commenter 19114 states that for IGCC units, the EPA should clarify the use of heat input
and generation output terminology to account for (1) differences between coal-based (gasifier feedstock
-based) and syngas-based heat input; and (2) differences between syngas-based and natural gas-based
output during co-firing operations.

Response to Comment 27: The EPA is regulating IGCC units that burn synthetic gas derived from coal
and/or solid oil-derived fuel. Natural gas-fired EGUs are not subject to this final rule.

4. Fuel sampling and analysis.

Comment 28: Commenters 17716 and 17725 request that the EPA clarify whether units that fire a

739


-------
single type of fuel (e.g., diesel oil) are exempt from all fuel sampling and analysis requirements.
Although section 63.10005(c)(4) exempts units that fire a single fuel type from conducting fuel analysis
as part of the initial compliance requirements, it does not address other fuel sampling requirements.
Section 63.1001 states, "you must also conduct fuel analyses according to §63.10008 and establish
maximum fuel pollutant input levels" and includes specifics for handling single-fuel units. The
commenter questions whether the EPA intended to require single-fuel sources to conduct initial and
ongoing fuel sampling like the IB MACT approach since other sections appear to only require fuel
sampling when burning a new fuel type.

Comment 29: In addition to the fuel sampling clarification, commenter 17716 also recommends that the
EPA expand the exemption in section 63.10005(c)(5) to cover units that fire multiple fuel types or
blends in the final rule. The section states that, fuel sampling and analysis are not required for single-
fuel units using supplemental fuels that are used only for startup, shutdown or for maintaining flame
stability.

Comment 30: Commenter 17775 requests that the EPA review and update the language regarding fuel
analysis tests in section 63.10008 and Table 6 to ensure clarity and consistency. Proposed section
63.10008 requires fuel analysis tests according to the "procedures in paragraphs (b) through (e)" and
Table 6. Paragraphs (c) and (d) specify minimum sampling procedure and compositing procedures.
However, Table 6 also provides sampling methods that can be used in lieu of those in paragraph (c) and
some of those procedures address compositing. The commenter requests that the language clearly state
that any procedure identified in Table 6 can be used in lieu of procedures in paragraphs (c) and (d).

Comment 31: Commenter 17796 states that "What Are My General Requirements for Complying with
this Subpart," paragraph (c)(2), clearly states that liquid oil-fired EGUs can demonstrate initial and
continuous compliance using fuel analysis for HC1, HF and total HAP metals but does not indicate that
Hg can be used in the fuel analysis to demonstrate compliance. The commenter states that non-Hg HAP
metals and Hg are generally segregated from other parameters for compliance determinations and
requests that the EPA address these constituents clearly and cohesively.

Comment 32: Commenter 17386 states that the fuel analysis provision appears to be in direct
contradiction to the discussion of this topic in the preamble of the rule (FR page 25053 Columnl},
which states (after the initial compliance demonstration by fuel analysis), "We are proposing that a
source be required to recalculate the fuel pollutant content only if it burns a new fuel type or fuel
mixture..."

Comment 33: Commenter 17718 requests that the EPA clarify the frequency of ongoing fuel
sampling/analysis required for purposes of comparison with "the maximum fuel input values calculated
during the last performance tests (if demonstrating compliance through performance stack testing) "

Comment 34: Commenter 17718 states that the establishment of fuel limits appears applicable only to
facilities that choose to comply via fuel analysis. If facilities apply CEMS, accurate compliance can be
determined at the emission point and, therefore, the fuel input becomes irrelevant. Additionally, there
are numerous inaccurate section/paragraph references within the proposed regulatory language of 40
CFR 63.10011(b). The EPA should carefully review this section to properly link references to the
appropriate sections and paragraphs.

Response to Comments 28 -34: The comments are moot because rule no longer requires fuel analysis
for pollutants.

740


-------
5. Subcategory comments.

Comment 35: Commenter 17843 supports fuel-based testing for compliance demonstrations by liquid
oil-fired units, but not stack testing every other month. The commenter notes the following
inconsistencies and clarity issues regarding liquid oil-fired units sections:

•	It is not clear that the language at section 63.10006(p) applies to low emitting EGUs and it is
difficult to understand how the timing set out in section 63.10006(o) follows in section
63.10006(p). The commenter suggests that sections 63.10006(f) and (g) should refer to Table 6
(Fuel Analysis Requirements), not 5 (Performance Stack Testing Requirements), which would
have more clearly allowed liquid oil-fired units to use fuel analysis to demonstrate compliance.
Commenter 16513 also states that this section is unclear and adds that it is unclear what the term
"continue to meet" in section 63.10006(p) means in the context of section 63.10006(o).

•	In section 63.10006(s), the opportunity to demonstrate compliance with the Hg, individual or
total non-Hg HAP metals, HC1, or HF emissions limit based on fuel analysis seems broader than
the liquid oil-fired limited use subcategory, but the description in the preamble (see (d) above)
appears to limit the fuel analysis compliance option to liquid oil-fired units that operate a limited
amount of time per year on oil and are inoperative the remainder of the year.

•	Commenters 17843 and 17796 both note that under section 63.10006 "When must I conduct
subsequent performance tests, fuel analysis or tune-ups?," it is clear that affected EGUs firing
solid oil-derived fuel and coal-fired must demonstrate continuous compliance with either CEMS,
or stack testing based upon the methodologies in Table 5, stack testing. It is not clear in this
section what is required for liquid oil-fired EGUs. In subdivisions (f) and (g), based upon EGUs
with or without non-Hg HAP metal controls, continuous compliance is demonstrated by either
every other month or monthly, respectively, performance testing (stack testing) based upon Table
5. In the same section 63.10006 subdivision (s), continuous compliance can be based upon fuel
analysis, which contradicts subdivisions (f) and (g). The general requirements state fuel analysis
is acceptable for liquid oil-fired EGUs for the initial and continuous compliance options these
issues and request continuous monitoring requirements for liquid oil-fired EGU should be
rewritten for parity and clarity.

Response to Comment 35: The comments concerning fuel analysis for pollutants are moot because rule
no longer contains this requirement. The rule has been revised to clarify compliance options for liquid
oil-fired EGUs, and the rule continues to allow an EGU owner or operator to choose a compliance
option, including quarterly emissions testing, use of CEMS, or, in certain circumstances, tune-ups or
fuel moisture analysis.

Comment 36: Commenter 17843 requests that the language in sections 63.10006(o), (p) and (s) be
updated to clearly state the monitoring requirements for oil-fired EGUs and to indicate that stack testing
is not intended to be conducted every two months.

Comment 37: Commenter 17718 recommends that the EPA clarify whether the fuel analyses and
procedures in section 63.10008 are only applicable to liquid oil-fired EGUs that desire to meet their
applicable emission limits through fuel sampling.

Comment 38: Commenter 17796 recommends that the requirements for the oil-fired units subcategory
be evaluated and revised for clarity with regard to initial and continuous monitoring parameters. For
example, although section 63.10005, Testing, Fuel Analysis and Initial Compliance Requirements,
subdivision (b) is clear that affected EGUs must demonstrate initial compliance with each of the

741


-------
applicable emission limits in Tables 1 and Tables 2 by conducting performance tests according to
section 63.10007 and Table 5 and either conduct fuel analysis, set operating limits or conduct
Continuous Monitoring System evaluations. It is not clear in subdivision (c) that liquid oil-fired EGUs
may choose to demonstrate compliance with fuel analysis. Subdivision (c) begins with compliance that
can be demonstrated by fuel analysis "except for those affected EGUs that meet the exemption in (c)(4)
and (c)(5) and those affected EGUs that opt to comply with individual or Total HAP metals limits in
Tables 1 and 2 which must comply by conducting a fuel analysis as described in paragraph (c)(1)." No
mention is made to paragraph (c)(2) which refers to HF or (c)(3). The commenter requests that
subdivision (c) and continuous monitoring requirements be rewritten for clarity, and that all language
regarding oil-fired units be evaluated for consistency and clarity.

The commenter states that section 63.10006(s), the opportunity to demonstrate compliance with the
mercury, individual or total non-mercury HAP metals, HC1, or HF emissions limit based on fuel
analysis seems broader than the liquid oil-fired limited use subcategory. The commenter recommends
that if it is not the EPA's intention to allow units other than liquid oil-fired limited use units to utilize a
fuel analysis compliance mechanism, the EPA should clarify the language.

Comment 39: Commenter 17718 states that section 63.10011(b) makes reference to conducting fuel
analyses and establishing maximum fuel pollutant input levels ." .as applicable." The commenter
requests that the EPA clarify that the fuel sampling, analyses, and maximum input levels are only
applicable to liquid oil-fired EGUs that choose to meet their emission limits through fuel sampling
methodologies.

Comment 40: Commenter 17881 states that if compliance via fuel sampling and analysis is only
available to liquid oil-fired units, then section 63.10021(a)(3) only applies to liquid oil-fired units, and
the rule should clarify this point. Additionally, the commenter requests that the provisions of sections
63.10011(c), 63.10021 (a)(6) and 63.10022(a)(6) should also specify that the paragraph applies only to
liquid oil fired units or possibly LEE.

Response to Comments 36 - 40: As mentioned elsewhere, the comments concerning fuel analysis for
pollutants are moot because rule no longer contains this requirement. The rule has been revised to clarify
compliance options for liquid oil-fired EGUs, and the rule continues to allow an EGU owner or operator
to choose a compliance option, including quarterly emissions testing, use of CEMS, or, in certain
circumstances, tune-ups or fuel moisture analysis.

Comment 41: Commenter 17174 states that the language in section 63.9983(b) for the natural gas-fired
EGU exemption contradicts the preamble of the rule. The commenter suggests that EPA use the
language in the preamble for the natural gas-fired EGU exemption in section 63.9983(b). Furthermore,
the commenter states that the language does not clearly state the types of fuel-fired EGUs which are
subject to this subpart. The commenter recommends that should be rewritten for clarity.

Comment 42: Similarly, Commenter 17881 notes that the preamble discussion is confusing and sheds
no light on the purpose of section 63.9983(b). The preamble discussion could lead one to the conclusion
that the proposed rule applies to all units other than natural gas-fired units (i.e., those units for which at
least 90 % of the annual average heat over a 3-year period, or more than 85 % of the annual heat input in
at least one year, is derived from natural gas).

Comment 43: Commenter 17881 states that the provisions of section 63.9983(b) are confusing because
rule only applies to coal- and oil-fired EGUs, and the percentage of heat input supplied by natural gas is

742


-------
not relevant if the unit is not classified as a coal- or oil-fired EGU. The provisions of section 63.9983(b)
state that EGUs which are not coal-fired or oil-fired EGUs and which combust natural gas for certain
minimum percentages of the annual average (i.e., >15 %) or 3-year average heat input (i.e., > 10 %) are
exempt from the rule. In cases where coal-fired or oil-fired EGUs co-fire such fuels with other fuels,
section 63.9983(c) already contains provisions on the relative amount of coal and/or oil firing (on a heat
input basis) which would subject the unit to the requirements of the rule.

Response to Comment 41 - 43: We believe that the definitions in the final rule along with other edits
related to situations where sources may "switch" source categories make the clarifications suggested by
the commenter.

Comment 44: Commenter 17758 recommends that the language for coal-based compliance should be
clarified. The commenter states that the most likely coal-based configurations able to comply with the
EPA's proposed rule will 1) opt for the total PM limit and utilize PM CEMS for continuous filterable
PM measurements; 2) employ some combination of wet or dry scrubbing, and/or DSI, for acid gas
control and elect to use already installed SO2 CEMS; and 3) directly monitor mercury using either a Hg
CEMS or a sorbent trap monitoring system. For the above-described scenario in which either all of the
regulated HAP or their surrogates are continuously monitored, the commenter states that no additional
burdens (e.g., coal sampling, operating parameter limits, etc.) should be imposed. Although the
commenter believes that the EPA does not intend to create additional burdens, the proposed rule is
drafted is unclear and it is recommended that the language be updated for clarity.

Response to Comment 44: Although the agency is appreciative of the commenter's view that the
agency does not intend to create additional burdens, the rule must be written with all EGUs in mind, not
just the majority. As mentioned elsewhere, the rule has been revised not to require additional
compliance information from those EGU owners or operators who choose to use CEMS or sorbent trap
monitoring as the means for compliance determination.

Comment 45: Commenter 17881 recommends that section 63.10006(e) be updated to reduce
confusion. The paragraph pertains to those solid oil-fired and coal-fired EGUs without either a PM
CEMS or PM control device. On the surface, it is hard to imagine any coal or petroleum coke fired
boilers being operated without PM controls, so it is assumed that this paragraph must apply exclusively
to IGCC units. To eliminate any possible confusion, the commenter suggests that the EPA replace the
term "solid oil-fired and coal-fired EGUs" with "IGCC unit" (Note that the definition of IGCC unit at
section 63.10042 already incorporates the concept of solid oil or coal being used in the gasification
process).

Response to Comment 45: The agency disagrees with the commenter, noting that the rule must be
written to cover all possible control device scenarios, not just the ones believed to exist at the present
time. As a result, no change to the rule has been made.

6. Operating limits comments.

Comment 46: Several commenters (17752, 17725, 17800) note that the rule contains conflicting
language regarding how operating limits are established. Section 63.10011(d) refers to the average of
three runs, while Table 4 of the proposed rule refers to the highest hourly average during the
performance test. Commenter 17800 states that use of the "highest hour" makes no sense if the EPA is
referring to Method 5 data, since runs are not measured in hours but in sample volume (and runs will be
more than one hour). Both commenters recommend that the EPA provide a rationale for how a three-run

743


-------
performance test is sufficient to capture operational variability of a unit and revise the operating limits
language to be consistent across both sections, as opposed to allowing for a 30 boiler operating days as
done for the other HAP. Commenter 17725 recommends establishing a FPM limit as a surrogate for
non-Hg metal HAP instead of TPM, which would do away with the need for a PM "operating limit."

Comment 47: Commenters 17681 and 17800 state that operating limits, including operating load limits
and fuel limits, should not be established for units using CEMS for compliance because requirements to
measure operating parameters are unnecessary and overly burdensome. For facilities using stack tests for
compliance, the commenter recommends that the EPA allow sources to develop a CAM plan as an
alternative to mandating operating limits, including operating load limits and fuel limits.

Comment 48: Commenter 17881 states that the procedures in Table 7 are not consistent with the
provisions of section 63.10011(b)(6) or the definitions in section 63.10042. The commenter requests
that, for Table 7, the EPA clarify that operating limits only apply in cases where CEMS are not used and
does not apply for HF/HCl/Metals when you are demonstrating compliance with the surrogate standards.
The commenter requests that consideration be given to the form of the DSI or ACI rates as an absolute
mass will not work at reduced loads. For ACI, the rate has often been specified as lb ACI/mmACFM of
flue gas.

Comment 49: Several commenters (17881, 17725, 18498) state that the limits for other operating
parameters are inconsistent. Section 63.10042 defines the minimum operating parameters limits
(minimum scrubber effluent pH, minimum pressure drop, minimum scrubber flow rate, minimum
sorbent injection rate and minimum voltage or amperage) as 90 % of average value measured during the
most recent performance test. However, Table 4 states that the parameters must be maintained "at or
above the lowest 1-hour average" from the performance test. Commenter 18498 states that the "one-
size-fits all" operating parameter limit approach should be revised to allow sources greater flexibility in
defining representative operating parameters. Commenter 17881 requests the EPA must provide
clarification as to how the operating limits are to be established.

Comment 50: Commenter 17718 states that the regulatory language seen in 40 CFR 63.10006 (a), (b),
(d), (h) and (i) does not seem to allow for process improvements. As written, subsequent performance
tests must be conducted "during the same compliance test period and under the same process (e.g., fuel)
and control device operating conditions." Process improvements discovered after initial compliance
testing could potentially allow for the same or better control of emissions yet move the control device
operating conditions outside of what was established as the "operating limits" established per Tables 4
and 7 of the proposed rule. The commenter suggests that the "same process and control device operating
conditions" language be removed from these regulatory sections to be similar to language proposed in
40 CFR 63.10006 (e), (f), (g), (j), (k), (1), and (m) where testing under those "same conditions" is not
required.

Comment 51: Commenter 17718 notes that section 63.10022(a)(6) states that existing units with an
ESP in an emission averaging option must "maintain the monthly fuel content values at or below the
operating limit established during the most recent performance test. The commenter requests that the
EPA clarify why the presence of an ESP would require monthly fuel content determinations and
suggests that the reference should be removed from the proposed regulation.

Response to Comments 46-51: As mentioned elsewhere, the comments concerning control device
operating parameters and fuel analysis for pollutants are moot because the rule no longer requires them.
In addition, the Agency agrees that EGU owners or operators who choose to use CEMS as a compliance

744


-------
option need not conduct other monitoring, that the use of continuous operating parameters in existing
CAM plans or due to permitting or other program requirements is an appropriate means of assuring
compliance with this rule's emissions limits between emissions testing, and that a clarification on
establishment of operating parameters for those EGU owners or operators who choose to use PM CPMS
as a compliance option is needed; the rule now addresses each of those items.

7.	Normal operating load.

Comment 52: Commenter 17174 states that section 63.10009(e) requires performance tests to be
conducted at "maximum normal operating load." However, section 63.10009(g)(2)(vii) requires
demonstration of compliance with each of the applicable emission limit(s) to be achieved under
"representative operating conditions." The commenter requests that the EPA clarify this discrepancy and
clearly define in section 63.10042 what constitutes maximum normal operating load or representative
operating conditions.

Comment 53: Commenter 17731 states that the term "maximum normal operating load," section
63.10007(c), should be clarified and distinguished from "representative normal operating load."

Response to Comments 52 and 53: The agency has reviewed the commenters' concerns and revised
the rule such that emissions testing is to occur at normal operating conditions. Moreover, if an EGU
owner or operator wishes to demonstrate compliance under other than normal operating conditions, the
rule requires emissions testing at those other conditions.

8.	30-day rolling averages.

Comment 54: Commenter 17821 has the following recommendations regarding 30-day rolling
averages:

•	Section 63-10010(b)(5) contains language that could be interpreted to mean that an O2
monitoring system is required for compliance with these regulations. The last sentence of this
paragraph references developing 30-day rolling averages from "hourly oxygen emissions data."
Paragraph (b) of this section references using CO2 monitoring. The commenter recommends that
paragraph (5) of this section be modified to reference averaging either O2 or CO2 emissions data,
if the EPA believes that O2 andCC>2 are necessary.

•	Section 63.10010(b)(5) also references using "all the hourly.. .emissions data" to develop 30-day
rolling averages. This language could be construed to mean that both valid and invalid data
should be used to develop long-term averages. The commenter recommends that paragraph (5)
be modified to include language to specify that only valid hourly data should be used to develop
30-day rolling averages.

•	Section 63.10010(c)(5)indicates that a 30-day rolling average for HC1 should be developed;
however the applicable engineering units are not specified. The commenter recommends that the
EPA specify the engineering units that apply to the 30-day rolling average. Furthermore, this
paragraph also references using "all the hourly HC1 emissions data" to develop 30-day rolling
averages. This language could be construed to mean that both valid and invalid data should be
used to develop long-term averages. The commenter recommends that paragraph (5) be modified
to include language to specify that only valid hourly data should be used to develop 30-day
rolling averages.

•	Section 63.10010 (e)(5) indicates that sources should develop 30-day rolling average for SO2 but
it does not specify the applicable engineering units. The commenter recommends that the EPA

745


-------
specify the engineering units that apply to the 30-day rolling average. Furthermore, this
paragraph also references using "all the hourly S02 emissions data" to develop 30-day rolling
averages. This language could be construed to mean that both valid and invalid data should be
used to develop long-term averages. The EPA should modify this paragraph to include language
to specify that only valid hourly data should be used to develop 30-day rolling averages.

• Section 63.10010 (g)(5) indicates that a 30-day rolling average for particulate emissions should
be developed; however, the applicable engineering units are not specified. The commenter
recommends that the EPA specify the engineering units that apply to the 30-day rolling
average. Furthermore, this paragraph also references using "all the hourly particulate emissions
data" to develop 30-day rolling averages. This language could be construed to mean that both
valid and invalid data should be used to develop long-term averages. The EPA should modify
this paragraph to specify that only valid hourly data should be used to develop 30-day rolling
averages.

Comment 55: Commenter 17681 notes an inconsistency between section 63.10010(g)(5) and Table 8.
Section 63.10010(g)(5) states that 30-day rolling average is calculated as "the average of all of the
hourly particulate emissions data for the preceding 30 boiler operating days." In contrast, Table 8 states
that the source is to convert "hourly emissions concentrations to 30 boiler operating mg/dscm values,"
which suggests that compliance is assessed on the average of 30 individual daily values. Commenter
17681 also notes that the methods to calculate the 30-day rolling average is unclear and requests that the
EPA clarify that a 30-operating day is based on the average of all applicable hours in the 30-day period.

Response to Comments 54 and 55: As mentioned elsewhere, the rule now allows C02 or 02 CEMS to
be used, clarifies that only valid hours are to be included in the 30 boiler operating day rolling average,
identifies the reporting units as either pounds per heat input or pounds per electrical output, and clarifies
that the 30 boiler operating day rolling average is based on the average of all valid hours in the
preceeding 30 days of boiler operation.

9. Fuel mixtures and switches.

Comment 56: Commenter 17696 recommends that the EPA clearly state that performance testing on a
"fuel mixture" does not require performance testing using coal of the same classification/common name
that is provided by different suppliers, different mines or different seams. The commenter states that the
proposal's references to "fuel mixture" leave room for confusion even though the definition of "fuel
type" (section 63.10042) is clear that individual fuel types received from different suppliers are not
considered new fuel types. The EPA should clarify that, for example, if a subbituminous coal-fired unit
has different suppliers of subbituminous coal, then the unit can conduct performance tests while burning
any one of its suppliers' subbituminous coal (or mixture of the different supplier's subbituminous coals)
and is not required to conduct performance tests using each supplier's coal or to test using a blend of
subbituminous coal from each of its different suppliers.

Response to Comment 56: The agency considered the commenter's concern and disagrees with the
commenter's suggestion that the rule needs to offer additional clarification with respect to fuel switching
with the same fuel type. The rule maintains that EGU owners or operators are to operate at normal
operating conditions using normal fuels; if fuel conditions change, the rule requires the EGU owner or
operator to conduct additional emissions testing. If an EGU owner or operator wishes to avoid having to
be concerned about retesting based on fuel switching, he or she could use a CEMS option, rather than
the emissions testing option, to demonstrate compliance.

746


-------
Comment 57: Commenter 18034 requests that the rule should articulate which standard applies when a
unit fuel switches or when a unit burns blends of different fuels. Although units may have been designed
to burn coal with a heat content of less than 8,300 Btu/lb, several units can and may switch to coal with
a heat content greater than 8,300 Btu/lb. Fuel blending and fuel switching are common practices utilized
to minimize SO2 emissions and the commenter recommends that the EPA take into consideration and
encourage environmentally beneficial practices such as fuel blending and fuel switching.

Comment 58: Commenter 17781 recommends that the EPA clarify section 63.9982(d) regarding
switching coal rank or fuel type by revising the language as follows:

"An existing electric utility steam generating unit that has switched completely to burning
a different coal rank or fuel type is considered to be an existing affected source under this
subpart."

Response to Comments 57 and 58: The agency considered the commenters' concerns and disagrees
with the commenters' suggestions. As mentioned elsewhere, the rule maintains that EGU owners or
operators are to operate at normal operating conditions using normal fuels; if fuel conditions change, the
rule requires the EGU owner or operator to conduct additional emissions testing. If an EGU owner or
operator wishes to avoid having to be concerned about retesting based on fuel switching, he or she could
use a CEMS option, rather than the emissions testing option, to demonstrate compliance. Moreover, the
Agency sees no need to include the commenter's suggested language changes in the rule because such
changes could be misconstrued as changing the current definition of modification.

Comment 59: Commenters 17808 and 17870 seek clarification on the compliance requirements for
units that may change from being "natural gas-fired" to "fossil fuel-fired." A natural gas-fired
generating unit may be forced to combust oil to maintain electric system reliability, and could suddenly
change from being an unregulated natural gas-fired unit to a regulated fossil fuel-fired generating unit (if
the EPA does not adopt the above-proposed definition for curtailment). Outside of curtailment
situations, a dual-fired unit may also burn oil if prices are competitive relative to natural gas or for other
reasons. The proposed rule is unclear with regard to how much time the EPA would allow a newly-
designated fossil fuel-fired unit to schedule and perform its initial performance tests to demonstrate
compliance with the applicable standards. Commenter 17870 recommends a period of 180 days from the
date that a unit newly meets the definition of an affected fossil fuel-fired unit subject to the rule.

Response to Comment 59: Although the agency has considered the commenter's suggestions, the rule
remains unchanged. An EGU owner or operator must remain cognizant of the definitions in the rule,
especially, for this instance, the definitions of natural gas-fired electric utility steam generating unit and
of oil-fired electric utility steam generating unit, along with rule requirements that trigger applicability
and compliance dates.

10. S02 comments.

Comment 60: Commenter 18498 notes that for SO2 CEMS, section 63.10021(a)(13) does not include
the option to use the Part 75 certification and ongoing QA/QC requirements as allowed in section
63.10010(e). Commenter 17705 suggests that section 63.1002l(a)(13)(ii) should include a cross-
reference to section 63.10010 allowing use of 40 CFR Part 75 certified monitors to conduct SO2
monitoring, with exceptions listed in section 63.10010 (e)(6). This cross-reference will help clarify that
monitors following the requirements of 40 CFR Part 75 can be used in lieu of monitors following 40
CFR Part 60.

747


-------
Comment 61: Commenter 17716 recommends that the EPA use the Part 75 text on linear check tests
instead of the text section 63.10010(e)(6)(ii), which states that one "must perform the linearity check test
required in appendix A to Part 75 on the SO2 CEMS whether or not it has a span of 30 ppm or less." The
Part 75 exemption was developed on the basis that a linearity check "begins to lose its significance" at
span values less than or equal to 30 ppm (63 FR 28032/28061 (May 21, 1998)).

Comment 62: Commenter 17714 requests that the EPA clarify the language placement of the SO2
monitor at the outlet of the EGU in section 63.10010(e) to definitively state that it refers to placing the
monitor in the stack downstream of the SO2 control device for the EGU.

Comment 63: Commenter 17821 notes an unintended conflict between sections 63.10010 (e) and (e)(1).
In paragraph (e), the EPA clearly states that sources operating an SO2 monitoring system for purposes of
compliance with 40 CFR Part 75 may continue to do so under these proposed rules. However, in
paragraph (e)(1), the rule defines and limits the operation and quality assurance to specific sections of 40
CFR Part 60 without referencing the prior alternative to operate an S02 CEMS under 40 CFR Part 75.
The commenter recommends that the EPA modify paragraph (e)(1) of this section to clearly state the
EPA's intended use of 40 CFR Part 75 for applicable sources.

Response to Comments 60 - 63: As mentioned elsewhere, the rule has been clarified to allow use of
Part 75 procedures for those CEMS subject to the rule and used in the Acid Rain Program. Moreover,
the rule has been clarified so that CEMS are to be placed at the outlet of an EGU.

Comment 64: Commenterl7881 states that none of the definitions for the term Er (regarding rolling
emission averages in Equations 1 through 5) mention SO2, but there do not seem to be any prohibitions
from averaging SO2 emission rates (assuming that all units included in the averaging plan would need to
be eligible to use the SO2 surrogate). The commenter suggests that SO2 be added to the list of pollutants
included in the term Er.

Comment 65: Commenters 18498 and 17725 recommend that the EPA add a subsection to section
63.10010(e), which clarifies that bias adjusted data and Part 75 missing data shall not be used in
calculating the 30 boiler operating day average SO2 emission rate. Although this is discussed in
appendix A to subpart UUUUU for Hg CEMS (Reference appendix A sections 1.4 and 4.1.2.4), this data
exclusion is not clearly stated for SO2 CEMS.

Response to Comments 64 and 65: The agency agrees with the commenter that SO2 should be included
in all equations with the term Er, and the rule has been revised to correct that omission. The agency
disagrees with the commenter that additional language concerning acid rain program requirements is
necessary for this rule. Should an EGU owner or operator lack SO2 hourly emissions data, no other data
would be valid and thus eligible for inclusion in a 30 boiler operating day rolling average. Moreover, the
EGU owner or operator would have to report the period of missing data to the Agency for further review
and potential enforcement action.

11. Testing guidelines and timeline comments.

Comment 66: Commenter 17821 recommends that the EPA review the inconsistencies regarding
section 63.10030(a) and section 63.10030(d). Section 63.10030(a) requires submission of all of the
notifications in section 63.7(b) and section 63.9(e). Proposed Table 10 also identifies section 63.7(b) and
section 63.9 as applicable. Sections 63.7(b) and 63.9(e) require notification of "intent to conduct a
performance test at least 60 calendar days before the performance test" is initially scheduled to begin.

748


-------
However, proposed section 63.10030(d) requires submission of a "Notification of Intent" to conduct a
performance test, but "at least 30 days before the performance test is scheduled to begin." Requiring
submission of two identical notices at different times makes no sense. If the EPA intends to allow
submission of the notice only 30 days before the test, the EPA should identify as "inapplicable" the
inconsistent notice requirements. If the EPA intends to require submission 60 days before the test, the
EPA must remove the redundant requirement in section 63.10030(d).

Response to Comment 66: The agency agrees with the commenter's concerns, and the rule will be
revised to have a consistent submission date for the notification of intent to conduct performance testing.

Comment 67: Commenterl7758 requests that the EPA specify whether the time ranges provided for
testing guidelines in section 63.10006(n) refer to calendar or operating days to avoid confusion. The
commenter recommends that the preferred option should be in terms of operating days or operating
quarters since these terms are used routinely by utilities to manage emissions program schedules and
give utilities the flexibility necessary for performing the required tests.

Response to Comment 67: The time ranges in the rule refer to calendar, not operating, days.

Comment 68: Commenter 17821 requests that the EPA either identify when EGUs are not required to
submit a Notice of Compliance Status or revise the section to make clear that all EGUs must submit
such a Notice. Proposed section 63.10031(e) requires EGUs to submit a "Notification of Compliance
Status" according to section 63.9(h)(2)(ii), "[i]f you are required to conduct an initial compliance
demonstration as specified in § 63.10011(a)." However, under proposed section 63.10005(a) all EGUs
"must demonstrate initial compliance with each of the applicable emission limits in Tables 1 or 2"
Moreover, section 63.9(h) on its face applies to each affected source when it becomes subject to a
relevant standard.

Response to Comment 68: The agency disagrees with the commenter's suggestion that an EGU owner
or operator is unable to determine whether or not he or she will need to provide notice of compliance
status based on the results of initial performance testing, whether for CEMS or for stack tests. The rule
language has not been revised.

Comment 69: Commenter 17821 requests that the EPA issue a rule that clearly articulates the various
compliance demonstration options. The commenter also notes that under paragraph (3), the Notification
of Compliance Status must include "[identification of whether you plan to demonstrate compliance
with each applicable emission limit through performance testing and fuel analysis; performance testing
with operational limits (e.g., CEMS for surrogates or CPMS); CEMS; or sorbent trap monitoring
system." The listed options do not appear to correspond with the rest of the proposed rule. For example,
proposed section 63.10011(b) appears to require all EGUs that conduct performance testing to perform
fuel analysis and to set operational limits.

Response to Comment 69: As mentioned elsewhere, much of the commenter's concern is moot
because rule no longer requires fuel analysis for pollutants or operational limits for control device
parameters. Although the Agency disagrees with the commenter's assertion that the rule is unclear with
respect to compliance demonstration options, the rule has been revised to further clarify the options
available to EGU owners or operators.

Comment 70: Commenter 17881 states that the language in section 63.10009(j)(2) regarding each
affected and non-affected unit meeting the most stringent emission limit is confusing, as non-affected

749


-------
units do not have any applicable emission limits under the proposed rule. The commenter questions
whether the intent is to simply allow the common stack to comply with the most stringent emission limit
that applies to any of the affected EGUs that exhaust to the common stack. If so, the commenter
recommends that the regulatory language should more clearly reflect this intent.

Response to Comment 70: The agency disagrees with the commenter's concern that the language
regarding appropriate emissions limits from differing units sharing a common stack is confusing. The
rule retains language requiring an EGU owner or operator who chooses to use emissions averaging to
shut down units not subject to the rule during performance testing or to operate all units sharing a
common stack at or below the most stringent emissions limit to which any individual EGU is subject,
whether or not such individual EGU is subject to this rule. Should an EGU owner or operator remain
concerned about meeting the rule's requirements, he or she could choose not to use emissions averaging.

Comment 71: Commenter 17881 requests that section 63.10021(a)(4) be revised for clarity because
EGUs without HC1 CEMS are required to test monthly or bimonthly. Thus, the tests would already be
conducted within the frequency (60 days) specified in the paragraph.

Response to Comment 71: The comment is moot, for the rule now requires EGU owners or operators
who choose to use emissions testing as the compliance option for acid gas emissions limitations to
conduct testing every quarter.

Comment 72: Commenter 17718 requests the following modifications to improve the clarity regarding
performance testing:

•	Section 63.10006(o) states that the ability to decrease the frequency of performance testing from
annual (or more frequent) is available if testing shows emissions at or below 50 % of the
emission limit and if there are "no changes in the operation of the affected source or air pollution
control equipment that could increase emissions." The commenter requests that the EPA provide
clarification on what constitutes "no change" and what information would be needed to
successfully pass these criteria. For example, it is unclear whether the "no change" provision
applies to the affected unit and is not inclusive of the entire facility.

•	Section 63.10007(c) requires performance tests to be conducted "while burning the type of fuel
or mixture of fuels that has the highest content..." The commenter recommends that the EPA
clarify whether reference to "type of fuel" simply means that if bituminous coal is typically
burned, then bituminous coal is to be used during the test. This section does not appear to require
a determination that the highest chlorine (or other constituent) content bituminous coal be used
during the test. The commenter also suggests a clarification that "special fuels" are not required
or expected for the performance test.

•	Section 63.10007(f) states that "(p)erformance tests shall be conducted under such conditions as
the EPA Administrator specifies to the owner or operator...." The commenter recommends that
the EPA clarify whether it will specify when and how performance testing is to be completed,
beyond what is already proposed in other sections of the regulatory language. If the
specifications are the same the commenter recommends that section 63.10007(f) should be
removed.

Response to Comment 72: The agency disagrees with the commenter's suggestion that specific criteria
be enumerated concerning possible impacts of EGU operation on emissions for those EGU owners or
operators who choose to seek LEE status. Those EGU owners or operators are in the best position to
understand what changes could cause impacts on emissions and remain responsible for EGU emissions;

750


-------
should an EGU owner or operator be uncomfortable meeting the LEE eligibility requirements, he or she
need not apply. As mentioned elsewhere, the comment concerning highest pollutant content in fuel is
moot, as fuel analysis for pollutants is no longer required. Finally, as mentioned elsewhere, the rule now
requires emissions testing be performed at normal operating conditions.

Comment 73: Commenter 17718 requests that EPA clarify whether section 63.10009(c) requires that a
"pre-test" be conducted so that a comparison can be made between a "30 day after" value and the initial
compliance test. Section 63.10009(c) states that, ".. .the emission rate achieved during the initial
compliance test for the HAP being averaged must not exceed the emission level that was being achieved
on [...] or the control technology employed during the initial compliance test must not be less effective
for the HAP being averaged than the control technology employed on...." If a pre-test is required, the
EPA should specify the notification and submittal requirements for such a test.

Response to Comment 73: The rule has been revised so that an EGU owner or operator who chooses to
use emissions averaging must be able to demonstrate compliance on a 30 (or 90) boiler operating day
rolling average basis, which means that those owners or operators will need to ensure their existing units
have at least one set of 30 (or 90) boiler operating day average values if CEMS are used for compliance
determination and at least one completed emissions test with test results if emissions testing is used for
compliance determination by 180 days after the effective date of this rule. Should an EGU owner or
operator find these requirements to be of concern, he or she should choose not to use the emissions
averaging option.

12. Other comments.

Comment 74: Commenter 17711 states that the word "sources" as used in the last clause of sections
112(d)(3)(A) and (B) is ambiguous and, therefore, susceptible to reasonable interpretation. As the EPA
explains in the preamble, the word "sources" might be construed to refer to all sources in the given
category or subcategory. However, the word "sources" in the first clause of sections 112(d)(3)(A) and
(B) clearly refers to the sources for which the EPA has emissions information. Notably, the second use
of the word "sources" in section 112(d)(3)(A) also clearly is a reference to sources for which the EPA
has emissions information. So, it is reasonable to conclude that Congress intended the word "sources" to
have a consistent meaning for all purposes under these provisions. In other words, the reference "30 or
more sources" at the end of section 112(d)(3)(A) and "fewer than 30 sources" at the end of section
112(d)(3)(B) reasonably should be construed as a reference to sources for which the EPA has emissions
information. This interpretation avoids the "absurd results" described above and allows for the EPA to
naturally reconcile the application of sections 112(d)(2)(A) and (B) such that the number of sources for
which the EPA has emissions information in a given category or subcategory dictates whether sections
112(d)(2)(A) or (B) should apply.

Response to Comment 74: The EPA does not agree with the commenter's interpretation. When
Congress qualifies a word in one place but not others in the same section, the more reasonable inference
is that it intended the qualification to apply only to that one instance.

Comment 75: Commenter 18034 supports the proposed emissions averaging approach; however, the
EPA uses the term "applicable regulatory authority" exclusively in the context of submission, review,
and approval of the emissions averaging implementation plan, such as in section 63.10009. Sources may
incorrectly believe that the state regulatory authority is responsible for review and approval the
emissions averaging plans even if the state has not received delegation from the EPA for the specific
NESHAP rule. The commenter states that it is unnecessary for the EPA to use a separate term within the

751


-------
emissions averaging section. If a state accepts delegation of the final version of the proposed new
subpart UUUUU, using the term "administrator" would apply equally for the emissions averaging
provisions as it does to the other provisions of the rule. If a state has not received delegation for the
NESHAP rule, not only would the state have no authority to issue an approval under section
63.10009(g), the state is under no obligation to review the plans on the EPA's behalf. The commenter
recommends that the EPA should use the standard term of "the administrator" used elsewhere in the
proposed rule to avoid confusion.

Response to Comment 75: The agency agrees with the commenter's suggestion and has revised the
rule.

Comment 76: Commenter 17174 suggests the following areas which would benefit from additional
review and clarity.

•	Section 63.10009(a) states "you may demonstrate compliance by emission averaging among the
existing EGUs in the same subcategory, if your averaged emissions for such EGUs are equal to
or less than the applicable emission limit" However, section 63.10009(e)(1) states, "You must use
equation 1 of this section to demonstrate that the PM, HF, SO2, HC1, non-Hg HAP metals, or Hg
emissions from all existing units participating in the emissions averaging option do not exceed
the emission limits in Table 2." The commenter recommends that the same wording be used in
both sections in order to avoid confusion.

•	Section 63.10009(e)(1) requires a facility to use Equation 1 to demonstrate compliance with PM,
HF, S02, HC1, non-Hg HAP metals or Hg emissions, by using the emission rate as determined
during the most recent performance test and the maximum rated heat input capacity. The
commenter requests that the EPA clarify what constitutes the maximum rated heat input capacity
of a utility boiler due to the variability in reported heat input ratings for utility boilers.

•	Section 63.10009(g)(2) states that, "If affected units from nonaffected units vent to the common
stack, the units from nonaffected units must be shut down or vented to a different stack during
the performance test.," however it is unclear as to how one can have "affected units from
nonaffected units." The commenter suggests the phrase be evaluated and rewritten for clarity.

•	Although section 63.10009(g)(1) states that implementation plan "must" be submitted no later
than 180 days before the facility intends to implement the plan, section 63.10009(g) indicates
that implementation plan submittal is only necessary "upon request." The commenter
recommends that the requirement to submit an implementation plan for emission averaging
compliance should be evaluated and edited for consistency across sections. Commenter 17821
also seeks clarification regarding the discrepancy between sections.

•	Section 63.1002l(a)(16)(vii) should clarify whether performance tune-ups needs to be submitted
electronically to the EPA's Central Data Exchange (CDX) by using the Electronic Reporting
Tool (ERT), as required in other parts of this section (63.1002 l(a)(l 1) and (17)).

Response to Comment 76: Although the agency notes that the applicable emissions limit is the limit
obtained from Table 2 (or in the case of Hg from the EGUs designed for coal > 8,300 Btu/lb
subcategory, the limit given in §63.1009(a)(2)), the rule has been revised to be consistent. The agency
does not agree that additional clarification on maximum rated heat input capacity is needed; EGU
owners or operators should use the values submitted as part of the ICR process or as part of the acid rain
program. The rule has been revised such that the sentence of concern now begins as "If emissions from
affected units and from nonaffected units..." The rule has been clarified so that an averaging plan need
only be submitted if requested by the Administrator. As a performance tune-up is a performance test,
and the rule already requires performance test results to be submitted electronically using the CDX, no

752


-------
additional clarification language is needed.

Comment 77: Commenter 17716 requests the following corrections and clarifications:

•	The rule does not include the equations for calculating PM or HC1 mass emissions. Appendix A
only includes equations for Hg. Commenter 17725 also notes this issue.

•	Section 63.10009 (j)(3) references opacity requirements, however no opacity operating limits
have been introduced as part of the rule. Commenters 17725, 17775, 18498-A2, 19120-Aland
18014 also took notice and have requested that the issue be addressed.

•	Section 63.10010(b)(5) should be revised to include CO2. For example, "... the average of all of
the hourly oxygen or carbon dioxide emissions data for the preceding 30 boiler operating days."

Response to Comment 77: As mentioned elsewhere, Table 5 describes how mass emissions can be
calculated. The rule no longer contains opacity requirements, which were included in the proposal in
error. As mentioned elsewhere the rule has been revised to include CO2 as well as O2 measurements.

Comment 78: Commenters 17675 and 17718 request that the reference in section 63.10010(a)(4) to
"paragraph 2.1 of this section" does not specify if it is referring to appendix A or another paragraph 2.1.
The commenter s recommends that the rule clearly state the proposed monitoring methods for stacks on
units with main and bypass stacks.

Response to Comment 78: The agency agrees with the commenter, and the rule has been revised to
clarify installation requirements.

Comment 79: Commenter 17681 requests that the EPA further explain what constitutes sufficient
monitoring for control devices in section 63.10009(g)(2)(vi)(B).

Response to Comment 79: As mentioned elsewhere, this comment is moot for the rule no longer
requires monitoring of control device operational parameters.

Comment 80: Commenter 17730 states that the requirement to optimize the flame in the boiler and
optimize the emissions of CO and NOx lacks definition and needs explanation prior to the rule being
finalized in order to comment.

Response to Comment 80: Although the agency disagrees with the commenter's suggestion that the
flame optimization requirements need additional explanation, the rule has been clarified with respect to
these requirements.

Comment 81: Commenter 17756 requests that the EPA clarify the language regarding "dry flue gas
technology." The commenter states that the rule does not clearly indicate whether "dry flue gas
technology" includes both dry scrubbers and dry sorbent injection. The commenter recommends that the
EPA revise the language to specify that dry sorbent injection is an acceptable dry desulfurization
technology.

Response to Comment 81: We believe that the definition in the final rule clearly indicates that both
"dry scrubbers" and "dry sorbent injection" are included in "Dry flue gas desulfurization technology."

Comment 82: Commenter 18023 states that to provide efficient application of the proposed rule, 4.1.3
Diluent Gas, Flow Rate, and/or Moisture Monitoring Systems should state that "Monitors that have been

753


-------
certified and quality assured to meet the requirements of 40 CFR Part 60 and/or 40 CFR Part 75 are
acceptable for the purpose of calculating and reporting emissions without any additional certification or
quality assurance."

Response to 82: In the final rule, section 4.1.3 of Appendix A states that the flow rate, diluent gas, and
moisture monitoring systems that are used to convert Hg concentrations to units of the standard must be
certified according to 40 CFR Part 75. This is necessary, since all of the CEMS data will be collected
using the ECMPS system. Section 63.10005(d) specifies that if a continuous monitoring system has been
previously certified under another State or Federal program and is continuing to meet the on-going QA
requirements of that program, no additional performance evaluations of the monitoring system are
required for Subpart UUUUU, provided that the applicable requirements of §§63.10010(b) through (h)
are met.

Comment 83: Additionally, commenter 18023 states that section 3.2.1.4.2 is in conflict with section
3.1.7 where span value is defined but does allow rounding off the span value to the next highest integer
multiple of 10. This would essentially restrict the span value to either 2 |ig/m3 or 10 [j,g/m3. The rule
should allow the user to set the span value anywhere between 2 and 10 |ig/m3 as long as that range falls
within acceptable limitations of the NIST traceable calibrator.

Response to Comment 83: The final rule provides sources with greater flexibility in setting the span
value of the Hg monitor. The Hg concentration corresponding to the standard is doubled and then
rounded off to either: (a) the next highest integer; (b) the next highest multiple of 5 |ig/m3 or; or (c) the
next highest multiple of 10 |ig/m3.

Comment 84: Commenter 17881 states that section 63.10011(c)(5) should clarify whether compliance
can be based on all HAP metals in aggregate or individual metals.

Response to Comment 84: As mentioned elsewhere, this comment is moot for the rule no longer
requires fuel analysis of pollutants.

Comment 85: Commenter 17718 states that within the proposed regulatory language seen in 40 CFR
63.10005(1), it is mentioned that a "default diluents gas concentration value of 10.0 % 02 or the
corresponding fuel-specific CO2 concentration" are to be used during periods of startup or shutdown
when calculating emissions in units of "lb/MMBtu" or "lb/TBtu." The EPA should clarify how to
calculate the "corresponding fuel-specific CO2 concentration."

Response to Comment 85: As mentioned elsewhere, this comment is moot for the rule no longer
requires emissions limits during periods of startup or shutdown.

Comment 86: Commenter 17795 requests that the EPA make the following revisions:

•	In section 63.10005(k) on start-up and shutdown default values, the commenter requests the
following language be added: "For those CEM systems that measure on a wet basis use of the
moisture estimation as specified in 40 CFR 75 §75.11 (b) shall be acceptable for this provision."

•	Also in section 63.10005(k) on start-up and shutdown default values, the commenter requests the
following reference equations be added: 40 CFR 75, Appendix F, equations F-14a and F-14b.

•	In section 63.10010 (b), the commenter requests the following language be added: 40 CFR 75
QA/QC is sufficient to meet the CO2/O2 requirements of this regulation.

•	In section 63.10010 (e)(6)(iii), the commenter requests that the reference to a fourth level needs

754


-------
to be removed because there is no additional benefit or reason to run four gases during a
linearity. This additional calibration level will not make the system any more accurate.

Response to Comment 86: As mentioned elsewhere, the comments are moot, for the rule no longer
requires numerical emissions limits during periods of startup or shutdown, the rule allows use of Part 75
quality assurance requirements for those monitors that are also used in the acid rain program, and the
reference to a fourth level was removed from the rule, even though it was an optional requirement.

Comment 87: Commenter 17714 recommends that the definitional language regarding "monitoring
system malfunction" be moved into the definition area of the rule identified as section 63.10042 since it
appears to be more of a definition than a requirement.

Response to Comment 87: The final rule will include a definition of monitoring system malfunction in
the definitions section of the rule. That definition will mirror the definition for monitoring system
malfunctions found in the proposed rule.

Comment 88: Commenter 17881 requests the following clarifications and revisions:

•	Information regarding the unit or stack operating time [7.1.2.2] is not needed in order to calculate
the Hg emission rate in units of lb/GWh, nor is it needed to calculate the lb/TBtu emission rate.
Thus, the commenter requests that the requirement to collect this data be deleted.

•	The commenter also requests that the EPA clarify that the hourly gross unit load [7.1.2.3] is only
needed for those units which are attempting to demonstrate compliance with a lb/GWh Hg
emission limit.

•	Information regarding the hourly heat input rate [7.1.2.4] is not needed to support the lb/GWh
Hg emission rate calculations. The use of fuel factors in conjunction with the Method 19
equations allow the determination of a lb/TBtu emission rate without the need to determine the
hourly heat input rate. Thus, the requirement to collect this data should be deleted.

•	In the context of the lb/TBtu Hg emission rate determination, the F-factor is not used to calculate
the heat input rate. Thus, the commenter requests that section 7.1.2.6 should be revised as
follows: "The F-factor used to calculate the lb/TBtu Hg emission rate, consistent with section
6.2.1.2." Further, the EPA should clarify that this information is only needed for those units
which are attempting to demonstrate compliance with a lb/TBtu Hg emission limit (i.e., it is
totally unnecessary for lb/GWh calculations).

•	The commenter disagrees with the assertion in section 7.1.5 that volumetric flow rate records are
required for purposes of determining lb/TBtu emission rates pursuant to section 6.2.1. None of
the referenced Method 19 Equations (i.e., 19-1 - 19-9) rely on volumetric flow rate; rather, these
equations rely on pollutant and diluent concentrations, fuel factors, and in some cases, flue gas
moisture content. Thus, the EPA should clarify that volumetric flow rate measurements are only
required for those units relying on sorbent trap monitoring systems and/or conducting lb/GWh
mercury emission rate calculations.

•	Section 7.1.5.2.5 requires the reporting of hourly PMA, however the commenter states that the
requirement is not appropriate when missing data substitution is being prohibited.

•	Section 7.1.7 contains provisions related to diluent gas records in cases where compliance is
being demonstrated on a lb/TBtu basis. Section 7.1.7.1 currently states that CO2 or O2
concentrations are needed "in order to calculate hourly heat input values." The commenter states
that the preceding statement is incorrect, as the diluent gas values are being used to allow the
direct calculation of lb/TBtu emission rates based upon additional Hg concentration data and
appropriate fuel factors. The cited text in section 7.1.7.1 should be deleted. As noted for similar

755


-------
provisions within appendix A, section 7.1.7.2.5 relates to hourly PMA records and should be
deleted.

•	The monitoring plan reporting time lines also do not align with the related reporting provisions
in 40 CFR Part 63, subparts A and UUUUU. The EPA must carefully review the two sets of
reporting provisions and clearly reconcile any differences between the provisions.

Response to Comment 88: The agency has reviewed the commenter's suggestions and in some cases
revised Appendix A of the rule. The rule retains requirements for collecting operating time and gross
unit load; EGU owners or operators who do not need these values to determine their unit's compliance
need not collect these data. Rule text has been revised to remove hourly heat input rate from section
7.1.2.4, as well as section 7.1.2.6. The rule has been revised so that section 7.1.5 refers only to
volumetric flow from EGUs that use sorbent trap monitoring systems and that percent monitoring
availability (PMA) is no longer included. The language in section 7.1.7.1 has been revised "...to convert
Hg concentrations to units of the standard." Finally, the agency believes the reporting time lines are now
consistent.

Comment 89: Commenter 18034 states that section 63.10005(1) addresses the use of default 02 and C02
concentrations for input-based emissions calculations and the default power production rate for output-
based emissions calculations but does not explain what pollutant concentrations should be used. The
commenter requests that the pollutant concentrations be clearly stated. The commenter also requests that
the EPA revise the rule to address the calculation of emissions during a malfunction.

Response to Comment 89: As mentioned elsewhere, this comment is moot for the rule now requires
work practice standards, not emissions limitations, during periods of startup or shutdown.

Comment 90: Commenter 18034 states that provisions in the affirmative defense rules need
clarification or appear to be contradictory:

•	Section 63.10001(a)(4) unnecessarily requires additional conditions to meet an affirmative
defense to bypass a control device. In some circumstances, the bypass may be the most
appropriate temporary implementation while correcting or repairing a condition of upset, since
the upset may be with the control device itself. All actions required to meet an affirmative
defense are sufficiently listed in the other provisions of section 63.10001(a) and must be met,
including those actions designed to minimize emissions.

•	Section 63.10001(a)(7) lists a requirement that "All actions in response were properly
documented by properly signed contemporaneous operating logs," but does not define or
accurately describe what would fulfill that requirement.

•	Section 63.10001(a)(9) requires "a written root cause required to determine, correct, and
eliminate the primary cause of the malfunction." This inevitably leads to an owner or operator
attempting to describe a preventative action to an event that (by definition of one of the criteria)
was not preventable.

Response to Comment 90: We believe the language is clear, not contradictory in nature, and provides
an owner or operator a systematic and thorough approach for establishing an affirmative defense in the
event of a malfunction that results in an exceedance of a standard. Many of the conditions were modeled
after the conditions of the affirmative defense in the EPA's SIP SSM policy, which several states have
adopted into their SIPs. We do not have any indication that parties to enforcement proceedings have had
any significant difficulties applying the terms of these SIP affirmative defenses. (See, e.g., State
Implementation Plans: Policy Regarding Excessive Emissions During Malfunctions, Startup, and

756


-------
Shutdown (Sept. 20, 1999); Policy on Excess Emissions During Startup, Shutdown, Maintenance, and
Malfunctions (Feb. 15, 1983)). Other conditions were modeled after a Federal Implementation
promulgated by EPA. ((40 CFR 50.1312). The EPA's view is that use of consistent terms in establishing
affirmative defense regulations and policies across various CAA programs will promote consistent
implementation of those rules and policies. The EPA notes that the purpose of the root cause analysis is
to determine, correct, and eliminate the primary cause of the malfunction and that the root cause analysis
itself does not necessarily require that the cause be determined, corrected or eliminated. However, in
most cases, the EPA believes that a properly conducted root cause analysis will have such results.

Comment 91: Commenter 18498 states that section 63.10010(b)(5) should be revised to include CO2.
For example, the commenter recommends that the language be amended to state:

"... the average of all of the hourly oxygen or carbon dioxide emissions data for the
preceding 30 boiler operating days."

Comment 92: Commenter 18498 notes that section 63.10021 (a)(10)(ii) does not include a reference to
CO2 records.

Response to Comments 91 and 92: As mentioned elsewhere, the rule now includes carbon dioxide as
well as oxygen, where oxygen is referenced.

Comment 93: Several commenters (17730, 17758, 17800) state that several provisions indicate that the
requirements apply "as applicable," but few provisions clearly state to which EGU subcategory or to
which option the requirement applies. For example, the overuse of "as applicable" makes it difficult for
the regulated source, or the state agency that will likely implement the program, to fully understand the
requirements or demonstrate compliance with the chosen option. Commenter 17758 recommends that
the EPA update the regulatory language to be consistent with its intent (e.g., unnecessary parameter
limits which are not meant to apply when CEMS are used). The commenter further states that requiring
excessive testing is inconsistent with EO 13563, as discussed elsewhere in these comments, which
requires agencies to tailor regulations to impose the least burden on society, consistent with obtaining
regulatory objectives.

Response to Comment 93: The agency disagrees with the commenters' suggestions. An EGU owner or
operator who does not have applicable requirements is not subject to the provisions of the rule, e.g., an
owner or operator who chooses to use CEMS as the compliance demonstration method is not subject to
the frequent emissions testing compliance demonstration method. Apart from some clarification, the rule
remains unchanged. As mentioned elsewhere, the rule no longer requires separate operating parameter
monitoring from emissions control devices if CEMS are used as the compliance demonstration method.
Although the emissions testing frequency has been reduced to quarterly, it remains consistent with
supplying the information necessary to show compliance with the emissions standard. Should an EGU
owner or operator find the emissions testing compliance method too burdensome, he or she should
choose from among the other options for demonstrating compliance with the emissions limits.

Comment 94: Similarly, commenter 17800 states that due to the incorrect references to sections,
incorrect citations and many other inconsistencies and misstatements within the proposed rule, it is
difficult for the commenter to evaluate what is needed to comply and determine the best plan for
compliance with this rule. The commenter requests that remove the many inconsistencies noted before
sources are expected to justify the expenditures associated with compliance to its shareholders, its rate
payers and its regulators such as the public service commission.

757


-------
Response to Comment 94: As mentioned elsewhere, the rule has been revised to remove
inconsistencies based on the Agency's review and commenter's suggestions.

Comment 95: Commenter 17909 states that the non-Hg metal HAP rules and compliance provisions
portion of the proposed rule are indiscernible. Despite diligent, protracted study of the rule, participation
in many, many conference calls and discussions with consultants, lawyers and the EPA staff, the
commenter is unable to follow the rationale in the rule and therefore cannot apply the requirements to
our affected source, plan for compliance or effectively comment on the proposed rule.

Response to Comment 95: Although the agency remains concerned that an EGU owner or operator
claims difficulty understanding non-Hg metals rule options, the rule's flexibility in that regard appears
to be understood, if not welcomed, by a large majority of commenters. Basically, an EGU owner or
operator chooses a PM emissions limit, or individual non-Hg metals emissions limits, or a total non-Hg
metals emission limit and demonstrates compliance based on that choice. Depending on the emissions
limit, compliance options range from frequent emissions testing to use of PM CPMS to use of PM
CEMS. Notwithstanding a few clarifications as discussed elsewhere, the rule maintains this flexibility.
The commenter should contact the Agency if he or she remains confused as to the rule requirements.

Comment 96: Commenter 17254 urges the EPA to re-propose the rule to address statistical errors in the
calculation of the proposed emission standards for Hg. Commenter cannot comment meaningfully on the
rules until we know what standard the agency ultimately will propose.

Response to Comment 96: We have corrected the errors noted during the public comment period as
soon as they were brought to our attention and believe that commenters had sufficient review time with
the corrected values to provide meaningful comment. Consequently, the EPA does not believe that
reproposal is necessary or required.

Comment 97: Commenter 17689 states that the EPA construes "the requirements of the act" to mean
only acid rain control when evaluating effects of other CAA program EGU emission reductions on EGU
HAP emissions. The language here is clear and unambiguous: "requirements of the act" cannot be read
to include only acid rain control.

Response to Comment 97: To the extent that EGUs are subject to other control requirements
established by states and tribes as part of their strategies to attain the NAAQS, these are not
"requirements of the act." Similarly, requirements established as a result of specific new source
permitting are in compliance with CAA-mandated programs but are not requirements of the act. The
EPA did not state that the only requirement of the CAA contemplated in section 112(n)(l)(A) was the
Title IV Acid Rain Program.

13. Reference and numerical corrections.

Comment 98: Commenter17796 notes that the Hg limit in the preamble is a typo and should read
0.0007 lb/GWh.

Response to Comment 98: The limits in the final rule have been reanalyzed and corrected.

Comment 99: Commenter 17848 notes that the preamble contains an error in the output-based limit for
Hg. The rule text indicates that the emission limit should be 0.008 lb/GWh, [however Table 1 indicates
that it is 0.00081b/GWh],

758


-------
Response to Comment 99: The limits in the final rule have been reanalyzed and corrected.

Comment 100: Commenter 17881 agrees with the intent of section 63.10005(1) but notes that the
proposed rule erroneously identifies this paragraph as 63.10005(1).

Response to Comment 100: The comment is moot because the rule now requires work practice
standards, not emissions limitations.

Comment 101: Commenterl7655 recommends that the paragraphs (p) and (q) in section 63.10006 be
renumbered as (o)(l) and (o)(2) because they are not free-standing but instead within the context of (o).
The commenter also recommends that if these changes are made, the references to paragraphs (p) and
(q), such as section 63.10006(n) be updated for consistency.

Response to Comment 101: The rule has been revised to consolidate the LEE requirements.

Comment 102: Several commenters (17696, 17718, 18037, 17821) note incorrect cross references in
the text of the proposed rule. For example, section 63.10006(r) states "If you are required to meet an
applicable tune-up work practice standard, you must conduct a performance tune-up according to
§63.10007. Each performance tune-up specified in § 63.10007 must be no more than 18 months after the
previous performance tune-up." Section 63.10007 addresses only performance testing. Commenter
17718 states that if "performance tune-ups" is the correct term, it appears that section 63.10021(a)(16)
would be the more accurate section reference.

Response to Comment 102: Although the agency believes a tune-up serves as the performance test for
certain EGUs for certain pollutants, the rule has been revised to describe the tune-up as a performance
tune-up.

Comment 103: Commenterl7174 notes the following editorial issues:

•	The last paragraph of section 63.10005(k) on start-up and shutdown default values for calculations is
numbered as (1).30 but should be labeled as (4) to continue the numbering of the section.
Commenters 17775 and 17795 also note this incorrect numbering.

•	The word "limit" is missing at the end of the last sentence of section 63.1 001 l(b)(6)(iv).

•	Section 63.10011 (c) states "and follow the procedures in paragraphs (c)(1) through (c)(7) of this
section." however there are only 6 paragraphs in section 63.10011 (c). Commenter 17881 also notes
this inconsistency.

Response to Comment 103: As mentioned elsewhere, the comments are moot because rule no longer
requires emissions limitations during periods of startup or shutdown, monitoring of control device
operational parameters, or fuel analysis for pollutants.

Comment 104: Commenterl7718 states that the reference in section 63.10010(b) to appendix A "..in
lieu of procedures in paragraphs (a)(1) through (a)(3) below...." is inaccurate because they do not pertain
to O2 and CO2 monitors. The EPA likely needs to correct this reference to (b)(1) through (b)(5).

Response to Comment 104: The cross-reference to paragraphs (a)(1) through (a)(3) was clearly
incorrect, and should have been (b)(1) through (b)(5), as noted by the commenter. Note, however, that in
the final rule, the Agency has removed the Part 60 certification and QA alternative for diluent gas
monitors, since all of the CEMS data will be collected using the ECMPS system. Section 63.10010(b) of

759


-------
the final rule specifies that the CO2 or O2 monitors must be certified and quality-assured according to
Part 75.

Comment 105: Commenters 17705 and 17775 note the following reference inconsistencies:

•	Section 63.10021 (a)(10) references compliance with paragraphs (a)(10)(i) through (iii), but
subsection (iii) is missing. Commenters 17821 and 17881 also note this inconsistency.

•	Section 63.10021 (a)(l 1) references compliance with paragraphs (a)(l l)(i) through (iv), yet the
rule text includes additional paragraphs (v) and (vi).

•	Section 63.10021 (a)(12) references compliance with paragraphs (a)(12)(i) through (iii), but
subsection (iii) is missing. Commenter 17881 also notes this inconsistency.

•	Section 63.10021 (a)(13) references compliance with paragraphs (a)(13)(i) through (iii), but
subsection (iii) is missing.

•	Section 63.10021 (a)(14) references compliance with paragraphs (a)(14)(i) through (iii), but
subsection (iii) is missing.

Response to Comment 105: The agency appreciates the comments, and the rule has been revised to
remove these inconsistencies.

Comment 106: Several commenters (19536, 19537, 19538) state that although the default diluents
language can be found in section 63.10005(k), Low Emitting EGUs, in the second numbered paragraph
(1), this appears to be a location error. The commenter states that it is not obvious where this paragraph
should be located. Commenter 17718 states that within the proposed regulatory language seen in 40
CFR 63.10005(k), the reference to performance test data requirements of "paragraph (1) of this section"
does not seem appropriate. The reference to "paragraph (1)" seems to point to "63.10005(1)" which
discusses default diluents gas concentrations to be used for calculating emissions during startup and
shutdown events and does not seem pertinent to "performance testing" mentioned in proposed
63.10005(b). The commenter requests that the EPA clarify or provide guidance on how these two
sections are to be used to aid qualification of LEE status.

Response to Comment 106: As mentioned earlier, these comments are moot, for the rule no longer
requires emissions limitations during periods of startup or shutdown.

Comment 107: Commenter-17775 notes the following incorrect or missing references:

•	Section 63.10005(k)(3) refers to section 63.10010(k)(3) however, there is no such provision.
Commenter 17696 also notes this inconsistency.

•	Section 63.10010(e) refers to procedures in (g)(1) through (g)(3) and (g)(6) however the EPA
may have meant (e)(1) through (3) and (e)(6). Commenters 17714, 17795, 17718 and 17881 also
note this inconsistency.

•	Section 63.10010(h) refers to CPMS "as specified in Table 5." Table 5 addresses "Performance
Stack Testing Requirements." Commenters 17752 and 17718 also note this incorrect reference.
Commenter 17718 states that it appears that the EPA should have referenced Table 4 or Table 7
instead.

•	The reference in section 63.10011(b) to paragraph (c)(6) should most likely be section
63.10011(b)(6). Commenter 17752 also notes this incorrect reference.

•	The numbering of paragraph in section 63.10011(b) is not sequential. There is no section (b)(5)
between (b)(4) and (b)(6). Commenter 17881 also notes this inconsistency.

•	Section 63.10021 (a)(8) refers to "maximum Hg input using Equation 9 of § 63.10011." The

760


-------
section and Equation 9 address non-Hg metals. Commenter 17752 also notes this incorrect
reference.

• Table 4 states "If you demonstrate compliance using ... Fuel Analysis, you must "[mjaintain the
fuel type or fuel mixture such that the applicable emission rate calculated according to
§63.10011(d)(3), (4) and/or (5).

Response to Comment 107: The comments are moot, as described elsewhere the rule no longer
requires operating parameter monitoring along with sorbent tube monitoring system monitoring, requires
the use of Part 75 monitoring for those sources that also use monitors for the acid rain program, requires
the establishment or monitoring of control device operating parameters, or requires fuel analysis of
pollutants.

Comment 108: Commenter 17752 notes an incorrect reference in section 63.10031 (c).

Response to Comment 108: Although the comment lacks specificity, the agency has reviewed the
section and revised the rule to correct references.

Comment 109: Commenter 17821 notes that appendix A, section 7.2.5.3.3 refers to paragraphs 7.1.2
through 7.1.19. Section 7.1 ends with paragraph 7.1.10.8. The EPA should modify this paragraph to
correct the misidentified range of paragraph numbers.

Response to Comment 109: The reference to section 7.1.19 was a typographical error, which has been
corrected in the final rule.

Comment 110: Commenters 17881 and 17718 note that paragraph (a)(4) of section 63.10010 references
"systems described in paragraph 2.1 of this section," but there is no paragraph 2.1. The commenter
suggests that it is likely that the EPA meant to reference section 2.1 in appendix A of proposed 40 CFR
Part 63, subpart UUUUU instead.

Response to Comment 110: The reference in §63.10010(a)(4) to "paragraph 2.1 of this section" was
clearly an error and has been removed from the rule.

Comment 111: Commenter 17881 notes that in paragraph 63.1002l(a)(14)(ii), the reference should
likely be "Appendix A of this part."

Response to Comment 111: The reference in §63.1002l(a)(14)(ii) to "procedure 5 in Appendix F of 40
CFR Part 60" was incorrect and should have been "Appendix A to this subpart", as suggested by the
commenter. However, note that in the final rule, all CEMS certification and QA requirements have been
removed from §63.10021 and have been consolidated in §§63.10010 (b) through (h).

Comment 112: Commenter17821 recommends that the EPA revise the reference in section

63.10021 (a)(16)(vi) to reflect the language in section 63.10006(r) which states that each performance

tune-up must be no more than 18 months after the previous tune-up.

Response to Comment 112: The agency has revised the rule so that the performance tune-up testing
frequency is consistent.

Comment 113: Commenter 18498 suggests that section 63.10021 (h)(ii) should be revised to reference
appendix A or more specifically, section 5 to appendix A. The commenter states that for Hg CEMS,

761


-------
section 63.10021 (h)(ii) states the "Quarterly accuracy determinations and daily calibration drift tests
shall be performed in accordance with procedure 5 in Appendix F of 40 CFR Part 60." and contradicts
section 63.10010(f) which references appendix A of this subpart.

Response to Comment 113: Section 63.10021 does not have a paragraph (h)(ii). The commenter is
probably referring to §63.1002 l(a)(14)(ii), which references Procedure 5 in Appendix F of Part 60. See
the response to Comment 113, above.

Comment 114: Commenter 17881 notes that the following references and sections are wrong:

•	reference to section 63.10021(a)(10) in section 63.10031(g)(1)

•	reference to section 63.10032(b) and (c) in section 63.10032(d)(5)

Response to Comment 114: The rule has been revised to correct the cross references.

Comment 115: Commenter 17718 states that that the reference in section 63.10021(a)(2) to section
63.10031(c) for keeping records of fuels should be section 63.10032(d) which outlines what fuel records
are to be kept.

Response to Comment 115: The comment is moot, for the rule no longer requires fuel analysis of
pollutants.

Comment 116: Commenter 17881 notes typographical errors in second sentence of section
63.10009(j)(2). The commenter recommends that the sentence be revised as follows:

"If affected units and nonaffected units vent to the common stack, the nonaffected units
must be shut down or vented to a different stack during the performance test or each
affected and each nonaffected unit must meet the most stringent emissions limit"

Response to Comment 116: As mentioned elsewhere, the rule has been revised to clarify the language.

Comment 117: Commenter 17691 notes the following typographical errors in the rule:

. At 76 FR 25036, ECPMS could be modified [ .. .], ECPMS should be ECMPS.

•	At 63.9990, "(2) EGUs designed for coal< 8,300 Btu/lb. (b) Oil-fired EGUs are [...], 40 CFR 63
.9990(b) should begin on the next line for better understanding. 76 FR 25103

•	At 63.10005, the numbering of the 63.10005(k) is out of sequence. The last paragraph, (1)
Startup and Shut down default [.. .],should be numbered (4) instead of (1). 76 FR 25106

•	At 63.10011, the numbering of the proposed 40 CFR 63 .1 0011 (b) is out of sequence. The
numbering skips (5). 76 FR 25114

Response to Comment 117: The agency agrees with the commenter's first two suggestions, and the
preamble and rule have been revised. No changes to the rule were made for the last two suggestions
since the rule no longer requires default values for calculations during periods of startup or shutdown
and since the rule no longer requires establishment of maximum pollutant fuel input levels.

Comment 118: Commenter 17691 states that the rule refers back to a site-specific monitoring plan
required by section 63.10000(d) in several places, however, section 63.10000(d) says there is an
exemption in which some sources will not need a site-specific monitoring plan (i.e., facilities with

762


-------
existing monitoring plans that meet the requirements of section 63.10010). Then, the proposed section
63.10010 refers back to 40 CFR 63.10000(d). The commenter states that this circular reference causes
confusion, makes the regulation difficult to follow, and should be eliminated. The commenter suggests
that for each instance where the text refers back to the proposed 40 CFR 63.10000(d), there should be
additional language to address the exemption.

Response to Comment 118: Although the agency disagrees with the commenter's assertions, the rule
has been revised so that only those EGUs without existing site-specific monitoring plans are required to
submit those plans.

763


-------
8E - Rule: Other Language Corrections
Commenter: 17851

Comment 1: Commenter 17851 states that it is impossible to eliminate the causes for certain
malfunctions, such as lightning strikes. The commenter also recommends that the EPA allow
notification by email or other electronic means in addition to faxing to make the rule more modern and
useful. The commenter requests that the rule be modified to include these notification methods.

Response to Comment 1: The agency agrees that some causes for malfunctions may be difficult to
eliminate, which is why the rule offers EGU owners or operators the ability to describe the
circumstances concerning a malfunction in a report. The agency understands and appreciates the
commenter's suggestion regarding use of electronic mail, but at this time the rule has not been changed
to allow it for notification purposes. As the agency works through security and routing issues, the rule
may be revised in the future to allow for electronic mail notification.

Comment 2: Commenter 17691 requests an inclusion of an equation in 40 CFR 63.10009 to provide a
compliance demonstration method for each individual affected unit exhausting through a common stack.

Response to Comment 2: The EPA disagrees with the commenter's suggestion. As mentioned
elsewhere, the rule contains instructions on how EGUs sharing a common stack and subject to an
emissions averaging program meet eligibility requirements and demonstrate compliance. No changes
have been made to the rule.

764


-------
CHAPTER 9: GENERAL SUPPORT AND GENERAL OPPOSITION

9A - General Support

Comment 1: The EPA received 677,132 mass-mail and form letters expressing general support for the
EGU NESHAP. Due to the high number of such comments for this proposed rule, these comments were
categorized and sorted according to the group that organized the mass-mailing.

The U.S. Docket office identified 664,695 mass-mail comment letters and assigned them to 65 DCNs.
These mass-mail DCNs are listed in Table 9A-1 of this section with the count of comment letters and the
associated organization.

More mass-mail comment letters were identified from the remaining comment letters and are listed in
Tables 9A-2 through 9A-20 in this section.

Three thousand and fifty (3,050) letters expressing general support that are not associated with any
mass-mail campaign are listed in Table 9A-21 in this section.

Many organizations provided members with form letters. Form letters containing substantive comments
had a few representative letters excerpted and summarized for the Response to Comments document,
and the remaining letters are listed here.

Many commenters representing the American Lung Association (18576, 18590, 18707, 18716, 18721,
18749, 18750, 18751, 18823, 18897, 18898, 18899, 18900, 18901 and 18930) wrote in support of the
proposed mercury and air toxics standards, particularly in regard to the standards' effect on human
health. Further comments from the American Lung Association can be found in the document in
comments from commenters 16826 and 18445.

Commenters (19111, 19210, 19225) representing chapters of the National Audubon Society, wrote to
support the proposed rule and its reduction of mercury impacts on wildlife. Other Audubon Society
commenters in this document are 17278, 17279, 17405 and 19101.

Commenters (16844, 17278, 17279, 17291, 17294, 17625, 18248, 18431, 18666, 19225) also expressed
general support for the proposed rule, citing benefits to human health and the environment, particularly
due to controls on Hg emissions. Commenters 17291, 17294 and 19225 encourage the EPA to make the
standard more stringent.

Comment 2: Commenter 18025 owns and operates four coal units and is part owner of four additional
units ranging in size from small to large, anticipates the units will achieve the proposed standards, and
therefore supports the proposed subcategories and emissions standards for coal-fired EGUs and agrees
that they are consistent with requirements in the CAA.

Response to Comments 1-2: The EPA appreciates the commenters' support for the Mercury and Air
Toxics Standards.

765


-------
Section 9A Tables
Mass Mailings - General Support for the Proposed Rule

Table 9A-1. Mass mail comments identified by the U.S. Docket Office

DCN

Docket Entry

Count

3084

Early Mass Comment Campaign sponsored by National Wildlife Federation
(NWF)

10,845

3085

Early Mass Comment Campaign sponsored by Environmental Defense Fund
(EDF)

66,532

3086

Early Mass Comment Campaign sponsored by League Of Conservation
Voters

65,149

3087

Early Mass Comment Campaign sponsored by Sierra Club

27,019

3088

Early Mass Comment Campaign sponsored by Union of Concerned
Scientists

10,872

3089

Early Mass Comment Campaign sponsored by American Lung Association
Action Network

2,116

3090

Early Mass Comment Campaign sponsoring organization unknown

3,053

3091

Early Mass Comment Campaign sponsored by Union of Concerned
Scientists

47

6638

Mass Comment Campaign sponsored by Greenpeace

4,685

11053

Mass Comment Campaign sponsored by Earthjustice

8,704

12055

Mass Comment Campaign sponsored by Earthjustice (Part 1 of 2)

3,112

12056

Mass Comment Campaign sponsored by Earthjustice (Part 2 of 2)



13059

Mass Comment Campaign sponsored by the League of Conservation Voters

593

13060

Mass Comment Campaign sponsoring organization unknown

78

13061

Mass Comment Campaign sponsored by Citizens for Pennsylvania's Future
(PennFuture)

172

13062

Mass Comment Campaign sponsoring organization unknown

202

13063

Mass Comment Campaign sponsored by Sierra Club

27,255

13421

Mass Comment Campaign sponsoring organization unknown

4,258

16530

Mass Comment Campaign sponsoring organization unknown

95

16531

Mass Comment Campaign sponsored by Environment Florida

43

16546

Mass Comment Campaign sponsored by Earthjustice

29

16547

Mass Comment Campaign sponsoring organization unknown

220

16553

Mass Comment Campaign sponsored by Natural Resources Defense Council
(NRDC)

9,678

16554

Mass Comment Campaign sponsoring organization unknown

513

16562

Mass Comment Campaign sponsoring organization unknown

73

16565

Mass Comment Campaign sponsored by Physicians for Social Responsibility

2,607

16566

Mass Comment Campaign sponsoring organization unknown

42

16567

Mass Comment Campaign sponsored by National Audubon Society

5,279

17007

Mass Mail Campaign sponsored by Alliance for Climate Protection

47,525

17030

Mass Mail campaign sponsored by First Congregational Church of Sonoma

28

17058

Mass Comment campaign sponsored by Environmental Defense Fund (EDF)

18,425

766


-------
17059

Mass Comment campaign sponsored by Natural Resources Council of Maine

123

17060

Mass Comment campaign sponsored by National Wildlife Federation Action
Fund

9,106

17802

Mass comment Campaign sponsored by Kentucky Environmental
Foundation

12

18190

Mass comment campaign sponsored by Sierra Club

9,440

18490

Mass Comment Campaign sponsored by Ohio Citizen Action

1,405

18491

Mass Comment Campaign sponsored by Fair Climate Project

52

18492

Mass Comment Campaign sponsored by Clean Air Council

49

18493

Mass Comment Campaign sponsoring organization unknown

39

18494

Mass Comment Campaign sponsored by Interfaith Power & Light

643

18495

Mass Comment Campaign sponsoring organization unknown

2,181

18496

Mass Comment Campaign sponsored by Restoring Eden

11,819

18546

Mass Comment Campaign sponsored by National Wildlife Federation
(NWF)

433

18638

Mass Comment Campaign sponsoring organization unknown

58

18639

Mass Comment Campaign sponsored by Citizens Campaign for the
Environment

33,165

18640

Mass Comment Campaign sponsoring organization unknown

67

18641

Mass Comment Campaign sponsoring organization unknown

29

18642

Mass Comment Campaign sponsoring organization unknown

105

18643

Mass Comment Campaign sponsoring organization unknown

2,611

18965

Mass Comment Campaign sponsored by CREDO Action

136,779

18979

Mass Comment Campaign sponsored by GASP (formerly Alabama First)

94

18986

Mass Comment Campaign sponsored by NC Conservation Network

904

18988

Mass Comment Campaign sponsored by One Million Calls For Clean
Energy

4,481

19112

Mass Comment Campaign sponsored by Greenpeace

77,844

19113

Mass Comment Campaign sponsoring organization unknown

20

19125

Mass Comment Campaign sponsored by Respiratory Health Association of
Metropolitan Chicago

94

19150

Mass comment campaign sponsored by Earthjustice

37,286

19550

Mass Comment Campaign sponsored by Fall-line Alliance for a Clean
Environment (FACE)

130

19573

Mass Comment Campaign sponsoring organization unknown

23

19615

Mass Comment Campaign sponsored by GreenFaith, Interfaith Partners in
Action for the Earth

13,074

19632

Mass Comment Campaign sponsoring organization unknown

25

19643

Mass Comment Campaign sponsored by Moms Clean Air Force

95

19644

Mass Comment Campaign sponsoring organization unknown

2,959

19647

Mass Comment Campaign sponsoring organization unknown

32

19648

Mass Comment Campaign sponsored by Environmental Defense Fund
(EDF)

269

Total:

664,695

767


-------
768


-------
In addition to the mass mailings identified by the Docket Office, 12,437 mass mail comments were also
identified by RTI International. Not all of the comments can be linked to a specific organization.

Table 9A-2. American Lung Association

3328

5122

5212

5216

7582

7583

7586

7587

7588

7658

7659

7662

7663

7664

7665

7666

7667

7668

7669

7670

7671

7673

7674

7675

7747

7828

7859

8287

8434

8520

8521

8579

8958

8961

9022

9072

9112

9154

9159

9172

9376

9790

11314

11915

12384

12409

12411

12418

12425

12430

12431

12439

12467

12508

12521

12589

12630

12639

12675

12676

12715

12716

12720

12768

12801

13099

13539

14288

14303

14345

14347

14844

14901

14952

14965

14969

14972

14973

15020

15171

15209

15230

15280

15387

15457

15525

16054

16073

16214

16215

16217

16228

16241

17075

17076

17080

17081

17082

17086

17146

17147

18531

18559

18663

18676

18678

18679

18680

18688

18698

18914

18945

19203

19250













Total:

114

Table 9A-3. National Audubon Society

14180

14186

14191

14227

14228

14230

14233

14235

14239

14243

14258

14259

14265

14266

14269

14270

14273

14276

14277

14278

14285

14289

14290

14291

14292

14293

14294

14295

14296

14297

14298

14302

14304

14305

14306

14307

14308

14320

14321

14322

14323

14324

14326

14351

14352

14353

14355

14356

14357

14360

14361

14362

14363

14364

14383

14384

14385

14387

14389

14396

14401

14412

14415

14438

14439

14452

14453

14454

14455

14456

14457

14458

14459

14727

14767

14768

14778

14779

14791

14793

14805

14841

14843

14846

14853

14902

14903

14950

14951

14953

14962

14963

14964

14966

14970

14974

14975

15003

15006

15016

15017

15019

15042

15044

15050

15060

15165

15166

15167

15168

15194

15195

15196

15198

15211

15244

15252

15264

15265

15267

15268

15275

15277

15278

15279

15289

15290

15291

15292

15293

15294

15295

15296

15297

15298

15299

15324

15325

15326

15327

15333

15334

15340

15342

15343

15346

15386

15346

15389

15390

15391

15399

15400

15401

15405

15406

15407

15409

15419

15420

15421

15422

15423

15461

15494

15498

15532

15681

15683

15684

15891

15895

15913

16011

16049

16060

16064

16065

16066

16067

16068

16069

16072

16080

16081

16083

16084

16092

16100

16104

16117

16218

16282

16312

16528

16587

















Total:

196

Table 9A-4. Care2Address

13791

13863

13864

13867

13869

13873

13874

13876

13880

13881

13882

13883

13888

13923

13983

17987

17988

17989

17990

17991

17992

17993

17994

17995

17996

17997

17998

18000

18001

18002

18003

18004

18005

18006

18007

18008

18010

18011

18012

18013

18050

18064

18069

18070

18071

18072

18073

18074

18075

18076

18077

18078

18079

18080

18081

18082

18083

18084

18085

18086

769


-------
18087

18088

18089

18090

18091

18092

18093

18094

18095

18096

18097

18098

18099

18100

18101

18102

18103

18105

18106

18107

18108

18109

18110

18113

18114

18115

18117

18118

18120

18121

18122

18124

18126

18127

18128

18129

18130

18131

18132

18133

18135

18136

18138

18140

18141

18142

18143

18144

18145

18146

18148

18149

18150

18151

18152

18154

18155

18156

18159

18161

18162

18163

18164

18165

18166

18167

18168

18169

18170

18171

18173

18175

18178

18179

18180

18181

18182

18183

18184

18187

18339

18340

18342

18343

18344

18345

18347

18345

18349

18350

18464

18466

18469

18470

18471

18473

18474

18578

18579

18587

18588

18589

18591

18592

18593

18594

18595

18596

18598

18629

18648

18651

18652

18656

18685

18691

18715

18717

18722

18723

18724

18725

18726

18727

18728

18766

18767

18781

18797

18798

18799

18800

18801

18802

18824

18825

18826

18827

18836

18851

18880

18881

18882

18883

18884

18976

18977

18978

18980

18982

18983

18984

18985

18989

18990

18992

18993

18994

18995

18996

18997

18998

18999

19000

19001

19002

19003

19031

19043

19044

19045

19046

19047

19048

19049

19050

19051

19052

19054

19055

19056

19058

19059

19060

19061

19062

19063

19064

19065

19066

19067

19068

19069

19070

19071

19072

19073

19074

19086

19087

19088

19092

19093

19106

19108

19110

19115

19116

19132

19133

19134

19136

19138

19139

19180

19181

19182

19183

19184

19186

19187

19190

19191

19306

19307

19333

19334

19335

19336

19337

19338

19339

19340

19341

19342

19343

19344

19345

19346

19347

19348

19349

19350

19351

19352

19353

19354

19355

19356

19357

19358

19359

19360

19361

19362

19363

19364

19365

19366

19367

19368

19369

19370

19371

19372

19373

19374

19375

19376

19377

19378

19379

19380

19381

19382

19383

19384

19385

19386

19387

19388

19389

19390

19391

19392

19393

19394

19395

19396

19397

19398

19399

19400

19401

19402

19403

19404

19405

19406

19407

19408

19409

19410

19411

19412

19413

19414

19415

19416

19417

19418

19419

19420

19421

19422

19423

19424

19425

19426

19427

19428

19429

19430

19431

19438

19439

19440

19441

19442

19443

19444

19445

19446

19447

19448

19449

19450

19451

19452

19453

19454

19455

19456

19457

19458

19459

19460

19462

19464

19465

19466

19467

19468

19470

19471

19472

19473

19474

19475

19476

19477

19478

19479

19480

19481

19482

19487

19492

19495

19499

19500

19501

19502

19503

19504

19505

19544

19567

19568

19569

19593

19608





Total:

443

Table 9A-5. Change.org

3640

3656

3657

3665

3666

3686

3687

3688

3698

3700

3703

3735

3736

3737

3738

3739

3793

3794

3795

3823

3907

3941

3942

3943

4001

4002

4003

4004

4005

4006

4007

4008

4009

4010

4011

4012

4014

4015

4016

4017

4018

4019

4020

4021

4022

4023

4024

4025

4026

4247

4250

4251

4253

4254

4255

4256

4257

4258

4259

4260

4261

4262

4263

4282

4284

4285

4287

4288

4289

4290

4303

4304

4305

4307

4308

4309

4310

4311

4312

4314

4315

4320

4347

4348

4349

4350

4351

4392

4393

4394

4395

4429

4430

4431

4454

4783

770


-------
4825

4999

5000

5014

5042

5053

5054

5065

5082

5097

5138

5182

5183

5190

5191

5203

5204

5264

5280

5348

5349

5350

5351

5352

5353

5354

5355

5356

5369

5413

5414

5415

5416

5691

5701

5702

5703

5704

5705

5706

5707

5708

5709

5710

5711

5712

5713

5750

5751

5752

5753

5752

5852

5854

5856

5857

6113

6114

6494

6495

6496

6497

6500

6508

6509

6514

6517

6518

6519

6523

6524

6525

6526

6527

6530

6531

6532

6533

14776











Total:

175

Table 9A-6. EarthJustice

12116

12117

12118

12119

12120

12121

12122

12134

12135

12136

12137

12138

12139

12140

12141

12143

12144

12157

12158

12159

12160

12161

12162

12163

12164

12165

12166

12167

12168

12169

12179

12180

12181

12182

12183

12188

12189

12194

12196

12197

12198

12199

12200

12212

12213

12214

12215

12217

12218

12219

12220

12291

12292

12293

12294

12300

12302

12303

12304

12305

12315

12318

12319

12320

12321

12322

12323

12324

12325

12326

12327

12328

12329

12330

12331

12333

12338

12340

12343

12346

12347

12348

12349

12350

12351

12352

12353

12354

12357

12358

12360

12361

12362

12363

12364

12365

12366

12367

12368

12370

12371

12372

12373

12679

13700

13712

13733

13767

13768

13769

13770

13771

13772

13773

13774

13775

13777

13778

13779

13780

13781

13782

13783

13784

13786

13787

13788

13789

13790

13792

13810

13811

13812

13813

13814

13815

13816

13861

13862

13865

13866

13870

13875

13878

13961

14034

14424

14034

14507

14508

14515

14516

14517

14518

14600

14601

14602

14603

14604

14605

14606

14607

14608

14609

14611

14615

14622

14623

14626

14627

14632

14633

14650

14653

14655

14663

14670

14676

14677

15792

15828

15867

15873

15875

15915

15917

15918

15919

15921

15922

15923

15933

15954

15960

15985

15999

16000

16383

16413

17327

17328

17491

17981

17999

18104

18111

18112

18125

18139

18147

18172

18177

18189

18250

18251

18252

18253

18255

18256

18257

18258

18264

18271

18273

18275

18351

18352

18355

18358

18359

18461

18462

18586

18597

18650

18653

18657

18658

18713

18718

18789

18834

18842

18847

19104

19105

19107

19137

19305







Total:

249

Table 9A-7. Environmental Defense Fund (EDF)

3092

3093

3094

3095

3096

3097

3098

3099

3100

3101

3102

3103

3104

3105

3138

3139

3140

3141

3142

3143

3144

3145

3146

3147

3148

3149

3150

3151

3152

3153

3154

3155

3156

3157

3158

3159

3160

3188

3223

3224

3246

3247

3248

3249

3250

3251

3252

3253

3254

3255

3256

3258

3259

3260

3261

3262

3263

3264

3265

3266

3267

3268

3269

3270

3275

3276

3277

3278

3279

3280

3281

3282

3283

3284

3285

3286

3287

3288

3289

3290

3291

3292

3293

3294

3295

3296

3297

3298

3299

3300

3301

3302

3303

3304

3305

3306

771


-------
3307

3324

3364

3384

3405

3417

3444

3497

3513

3555

3576

3592

3604

3616

3628

3641

3653

3669

3681

3699

3714

3726

3744

3764

3779

3791

3817

3835

3854

3877

3923

3952

3964

3976

3988

4000

4038

4075

4109

4121

4141

4170

4182

4194

3308

3309

3315

3316

3317

3318

3319

3320

3321

3322

3323

3325

3326

3327

3329

3330

3331

3334

3335

3336

3358

3361

3366

3367

3371

3372

3373

3375

3378

3379

3380

3381

3383

3389

3390

3392

3397

3398

3399

3400

3401

3402

3403

3404

3406

3407

3406

3409

3410

3411

3412

3413

3414

3415

3416

3418

3419

3420

3436

3437

3438

3439

3440

3441

3442

3443

3454

3455

3456

3457

3458

3459

3460

3461

3494

3495

3496

3498

3499

3500

3501

3502

3503

3504

3505

3506

3510

3512

3515

3516

3517

3518

3519

3549

3550

3551

3552

3553

3554

3556

3557

3558

3567

3569

3570

3571

3572

3573

3574

3575

3577

3578

3579

3580

3581

3582

3583

3584

3585

3586

3587

3593

3594

3595

3596

3597

3598

3599

3600

3601

3602

3603

3605

3606

3607

3608

3609

3610

3611

3612

3613

3614

3615

3617

3618

3619

3620

3621

3622

3623

3624

3625

3626

3627

3629

3630

3631

3632

3633

3634

3635

3636

3637

3638

3639

3642

3643

3644

3645

3646

3647

3648

3649

3650

3651

3652

3654

3655

3658

3659

3660

3661

3662

3663

3664

3667

3668

3670

3671

3672

3673

3674

3675

3676

3677

3678

3679

3680

3682

3683

3684

3685

3689

3692

3693

3694

3695

3696

3697

3701

3702

3704

3706

3707

3708

3709

3710

3711

3712

3713

3715

3716

3717

3718

3719

3720

3721

3722

3723

3724

3725

3727

3728

3729

3730

3731

3732

3733

3734

3741

3742

3743

3745

3746

3747

3756

3757

3758

3759

3760

3761

3762

3763

3765

3766

3767

3768

3769

3773

3774

3775

3776

3777

3778

3780

3781

3782

3783

3784

3785

3786

3787

3788

3789

3790

3792

3805

3806

3807

3808

3809

3810

3811

3812

3813

3814

3818

3819

3820

3821

3822

3827

3828

3829

3830

3833

3834

3836

3838

3839

3840

3841

3842

3843

3847

3848

3849

3853

3855

3856

3861

3862

3863

3864

3869

3870

3871

3875

3876

3878

3879

3884

3885

3886

3890

3895

3900

3908

3921

3922

3924

3925

3938

3939

3944

3945

3946

3947

3949

3950

3951

3953

3954

3955

3956

3957

3958

3959

3960

3961

3962

3963

3965

3966

3967

3968

3969

3970

3971

3972

3973

3974

3975

3977

3978

3979

3980

3981

3982

3983

3984

3985

3986

3987

3989

3990

3991

3992

3993

3994

3995

3996

3997

3998

3999

4013

4027

4028

4029

4030

4032

4033

4034

4035

4036

4037

4039

4040

4041

4042

4043

4044

4045

4046

4047

4049

4074

4076

4099

4100

4101

4102

4103

4104

4105

4106

4107

4108

4110

4111

4112

4113

4114

4115

4116

4117

4118

4119

4120

4122

4123

4124

4125

4126

4127

4128

4129

4137

4138

4140

4142

4143

4144

4145

4146

4147

4148

4162

4167

4168

4169

4171

4172

4171

4174

4175

4176

4177

4178

4179

4180

4181

4183

4184

4185

4186

4187

4188

4189

4190

4191

4192

4193

4196

4200

4216

4217

4218

4219

4220

4221

4222

4223

4224

772


-------
4225

4238

4266

4291

4316

4329

4345

4362

4388

4405

4418

4435

4452

4466

4478

4493

4509

4521

4540

4556

4572

4585

4597

4612

4626

4639

4655

4676

4698

4712

4726

4740

4753

4765

4796

4822

4982

5085

5245

5346

5458

6119

6131

6144

4226

4227

4228

4229

4230

4231

4232

4233

4234

4235

4236

4241

4242

4243

4244

4245

4246

4248

4249

4252

4264

4265

4268

4274

4275

4276

4277

4278

4279

4280

4281

4283

4286

4292

4293

4295

4296

4298

4299

4300

4301

4302

4306

4313

4317

4318

4319

4321

4322

4323

4324

4325

4326

4327

4328

4330

4331

4332

4333

4334

4335

4336

4337

4338

4339

4340

4346

4352

4353

4354

4355

4356

4357

4358

4359

4360

4361

4377

4378

4379

4380

4381

4382

4383

4384

4385

4386

4387

4389

4390

4391

4396

4397

4398

4399

4400

4402

4403

4404

4406

4407

4408

4409

4410

4412

4413

4414

4415

4416

4417

4419

4420

4421

4422

4423

4424

4425

4426

4427

4428

4433

4436

4437

4438

4442

4443

4444

4445

4446

4447

4450

4451

4453

4455

4456

4457

4458

4459

4460

4461

4463

4464

4465

4467

4468

4469

4470

4471

4472

4473

4474

4475

4476

4477

4479

4480

4481

4482

4484

4485

4486

4489

4490

4491

4492

4497

4498

4499

4500

4501

4503

4504

4505

4506

4507

4508

4510

4511

4512

4513

4514

4515

4516

4517

4518

4519

4520

4527

4528

4529

4530

4531

4532

4533

4534

4537

4538

4539

4542

4543

4546

4547

4548

4549

4550

4551

4552

4553

4555

4558

4559

4560

4561

4562

4564

4566

4567

4568

4569

4570

4573

4574

4575

4576

4577

4578

4579

4581

4582

4583

4584

4586

4587

4588

4589

4590

4591

4592

4593

4594

4595

4596

4598

4599

4602

4603

4604

4605

4606

4608

4609

4610

4611

4613

4614

4616

4617

4619

4620

4621

4622

4623

4624

4625

4628

4629

4630

4631

4632

4633

4634

4635

4636

4637

4638

4640

4641

4643

4646

4647

4648

4649

4650

4651

4652

4653

4656

4657

4658

4659

4660

4661

4663

4664

4669

4670

4675

4679

4680

4681

4682

4683

4691

4692

4693

4694

4695

4696

4699

4700

4701

4702

4703

4704

4707

4708

4709

4710

4711

4713

4714

4715

4716

4717

4719

4720

4722

4723

4724

4725

4727

4728

4729

4731

4733

4734

4735

4736

4737

4738

4739

4741

4742

4743

4744

4745

4746

4747

4748

4749

4750

4752

4754

4755

4756

4757

4758

4759

4760

4761

4762

4763

4764

4766

4767

4768

4769

4784

4785

4786

4787

4788

4789

4795

4798

4804

4798

4809

4810

4811

4812

4818

4819

4820

4821

4823

4824

4920

4922

4924

4926

4927

4928

4931

4933

4942

4983

4993

5005

5006

5007

5026

5027

5028

5029

5030

5031

5098

5142

5158

5159

5174

5175

5192

5193

5205

5206

5207

5247

5267

5268

5269

5295

5305

5318

5321

5330

5331

5345

5446

5447

5448

5449

5450

5452

5453

5454

5455

5456

5457

5459

5460

5517

5518

5560

5562

6112

6115

6116

6117

6118

6120

6121

6122

6123

6124

6125

6126

6127

6128

6129

6130

6132

6133

6134

6135

6136

6137

6139

6140

6141

6142

6143

6145

6146

6147

6148

6149

6150

6151

6152

6153

6154

6155

773


-------
6156

6168

6181

6193

6205

6217

6229

6241

6253

6265

6277

6289

6301

6313

6325

6337

6349

6361

6373

6385

6397

6409

6421

6433

6445

6457

6469

6481

6493

6512

6537

6550

6562

6574

6587

6599

6611

6623

6636

6675

6687

6700

6712

6724

6157

6158

6159

6160

6161

6162

6163

6164

6165

6166

6167

6169

6170

6171

6172

6173

6174

6175

6176

6178

6179

6180

6182

6183

6184

6185

6186

6187

6188

6189

6190

6191

6192

6194

6195

6196

6197

6198

6199

6200

6201

6202

6203

6204

6206

6207

6208

6209

6210

6211

6212

6213

6214

6215

6216

6218

6219

6220

6221

6222

6223

6224

6225

6226

6227

6228

6230

6231

6232

6233

6234

6235

6236

6237

6238

6239

6240

6242

6243

6244

6245

6246

6247

6248

6249

6250

6251

6252

6254

6255

6256

6257

6258

6259

6260

6261

6262

6263

6264

6266

6267

6268

6269

6270

6271

6272

6273

6274

6275

6276

6278

6279

6280

6281

6282

6283

6284

6285

6286

6287

6288

6290

6291

6292

6293

6294

6295

6296

6297

6298

6299

6300

6302

6303

6304

6305

6306

6307

6308

6309

6310

6311

6312

6314

6315

6316

6317

6318

6319

6320

6321

6322

6323

6324

6326

6327

6328

6329

6330

6331

6332

6333

6334

6335

6336

6338

6339

6340

6341

6342

6343

6344

6345

6346

6347

6348

6350

6351

6352

6353

6354

6355

6356

6357

6358

6359

6360

6362

6363

6364

6365

6366

6367

6368

6369

6370

6371

6372

6374

6375

6376

6377

6378

6379

6380

6381

6382

6383

6384

6386

6387

6388

6389

6390

6391

6392

6393

6394

6395

6396

6398

6399

6400

6401

6402

6403

6404

6405

6406

6407

6408

6410

6411

6412

6413

6414

6415

6416

6417

6418

6419

6420

6422

6423

6424

6425

6426

6427

6428

6429

6430

6431

6432

6434

6435

6436

6437

6438

6439

6440

6441

6442

6443

6444

6446

6447

6448

6449

6450

6451

6452

6453

6454

6455

6456

6458

6459

6460

6461

6462

6463

6464

6465

6466

6467

6468

6470

6471

6472

6473

6474

6475

6476

6477

6478

6479

6480

6482

6483

6482

6485

6486

6487

6488

6489

6490

6491

6492

6498

6499

6501

6502

6503

6504

6505

6506

6507

6510

6511

6513

6515

6516

6520

6521

6522

6528

6529

6534

6535

6536

6538

6539

6540

6541

6542

6544

6545

6546

6547

6548

6549

6551

6552

6553

6554

6555

6556

6557

6558

6559

6560

6561

6563

6564

6565

6566

6567

6568

6569

6570

6571

6572

6573

6575

6576

6577

6578

6579

6580

6581

6582

6583

6585

6586

6588

6589

6590

6591

6592

6593

6594

6595

6596

6597

6598

6600

6601

6602

6603

6604

6605

6606

6607

6608

6609

6610

6612

6613

6614

6615

6616

6617

6618

6619

6620

6621

6622

6624

6625

6626

6627

6628

6629

6630

6631

6632

6633

6634

6664

6665

6666

6667

6668

6669

6670

6671

6672

6673

6674

6676

6677

6678

6679

6680

6681

6682

6683

6684

6685

6686

6688

6689

6690

6691

6692

6693

6695

6696

6697

6698

6699

6701

6702

6703

6704

6705

6706

6707

6708

6709

6710

6711

6713

6714

6715

6716

6717

6718

6719

6720

6721

6722

6723

6725

6726

6727

6728

6729

6730

6731

6732

6733

6734

6735

774


-------
6736

6748

6760

6772

6784

6796

6808

6820

6832

6844

6856

6868

6880

6892

6904

6916

6928

6940

6952

6964

6976

6988

7000

7012

7024

7036

7048

7060

7086

7207

7219

7231

7243

7349

7500

7512

7524

7539

8587

9275

9529

9542

9555

9567

6737

6738

6739

6740

6741

6742

6743

6744

6745

6746

6747

6749

6750

6751

6752

6753

6754

6755

6756

6757

6758

6759

6761

6762

6763

6764

6765

6766

6767

6768

6769

6770

6771

6773

6774

6775

6776

6777

6778

6779

6780

6781

6782

6783

6785

6786

6787

6788

6789

6790

6791

6792

6793

6794

6795

6797

6798

6799

6800

6801

6802

6803

6804

6805

6806

6807

6809

6810

6811

6812

6813

6814

6815

6816

6817

6818

6819

6821

6822

6823

6824

6825

6826

6827

6828

6829

6830

6831

6833

6834

6835

6836

6837

6838

6839

6840

6841

6842

6843

6845

6846

6847

6848

6849

6850

6851

6852

6853

6854

6855

6857

6858

6859

6860

6861

6862

6863

6864

6865

6866

6867

6869

6870

6871

6872

6873

6874

6875

6876

6877

6878

6879

6881

6882

6883

6884

6885

6886

6887

6888

6889

6890

6891

6893

6894

6895

6896

6897

6898

6899

6900

6901

6902

6903

6905

6906

6907

6908

6909

6910

6911

6912

6913

6914

6915

6917

6918

6919

6920

6921

6922

6923

6924

6925

6926

6927

6929

6930

6931

6932

6933

6934

6935

6936

6937

6938

6939

6941

6942

6943

6944

6945

6946

6947

6948

6949

6950

6951

6953

6954

6955

6956

6957

6958

6959

6960

6961

6962

6963

6965

6966

6967

6968

6969

6970

6971

6972

6973

6974

6975

6977

6978

6977

6980

6981

6982

6983

6984

6985

6986

6987

6989

6990

6991

6992

6993

6994

6995

6996

6997

6998

6999

7001

7002

7003

7004

7005

7006

7007

7008

7009

7010

7011

7013

7014

7015

7016

7017

7018

7019

7020

7021

7022

7023

7025

7026

7027

7028

7029

7030

7031

7032

7033

7034

7035

7037

7038

7039

7040

7041

7042

7043

7044

7045

7046

7047

7049

7050

7051

7052

7053

7054

7055

7056

7057

7058

7059

7061

7062

7077

7078

7079

7080

7081

7082

7083

7084

7085

7087

7088

7198

7199

7200

7201

7202

7203

7204

7205

7206

7208

7209

7210

7211

7212

7213

7214

7215

7216

7217

7218

7220

7221

7222

7223

7224

7225

7226

7227

7228

7229

7230

7232

7233

7234

7235

7236

7237

7238

7239

7240

7241

7242

7244

7254

7255

7256

7302

7303

7304

7305

7346

7347

7348

7350

7351

7352

7353

7354

7355

7356

7357

7358

7496

7499

7501

7502

7503

7504

7505

7506

7507

7508

7509

7510

7511

7513

7514

7515

7516

7517

7518

7519

7520

7521

7522

7523

7525

7526

7527

7528

7529

7530

7531

7532

7533

7534

7538

8256

8257

8300

8301

8580

8581

8582

8583

8584

8585

8586

8588

8877

8878

8879

9268

9269

9270

9271

9272

9273

9274

9276

9518

9519

9520

9521

9522

9524

9525

9526

9527

9528

9530

9531

9532

9533

9534

9535

9536

9537

9538

9539

9540

9543

9544

9545

9546

9547

9548

9550

9551

9552

9553

9554

9556

9557

9558

9559

9560

9561

9562

9563

9564

9565

9566

9568

9570

9571

9572

9573

9574

9576

9577

9578

9579

9580

775


-------
9581

9582

9583

9584

9585

9586

9587

9588

9589

9590

9591

9592

9593

9594

9595

9596

9597

9598

9599

9600

9601

9602

9603

9604

9605

9606

9607

9608

9609

9610

9611

9612

9613

9614

9617

9618

9619

9620

9621

9622

9623

9624

9625

9626

9627

9628

9629

9630

9631

9632

9633

9634

9635

9636

9637

9638

9639

9640

9641

9642

9643

9644

9645

9646

9647

9648

9650

9651

9652

9653

9654

9655

9656

9657

9658

9659

9660

9661

9662

9663

9664

9666

9667

9668

9669

9670

9671

9672

9673

9674

9675

9676

9677

9678

9679

9680

9681

9682

9683

9684

9685

9686

9687

9688

9689

9690

9691

9692

9693

9694

9695

9696

9697

9698

9699

9701

9702

9703

9704

9705

9706

9707

9708

9709

9711

9712

9713

9714

9716

9718

9719

9720

9721

9722

9723

9724

9725

9726

9727

9765

9766

9767

9768

9769

9770

9860

9963

9964

9965

9966

9967

9968

9969

9970

9971

9972

9973

9974

9975

9974

9978

9979

9980

9981

9982

9983

9984

9985

9986

9987

9988

9989

9990

9991

9992

9993

9994

9995

9996

9997

9998

9999

10000

10002

10003

10004

10005

10006

10007

10008

10009

10011

10012

10013

10014

10015

10016

10017

10018

10019

10020

10021

10022

10023

10024

10025

10026

10027

10029

11064

11065

11066

11067

11108

11109

11110

11111

11112

11113

11114

11115

11116

11117

11118

11119

11120

11121

11122

11123

11124

11125

11126

11127

11128

11129

11130

11131

11132

11133

11134

11135

11136

11137

11139

11140

11141

11142

11143

11144

11145

11146

11147

11148

11149

11150

11151

11152

11153

11154

11155

11156

11157

11158

11159

11160

11161

11162

11163

11164

11165

11166

11167

11168

11169

11170

11171

11172

11173

11174

11175

11176

11177

11178

11179

11180

11181

11182

11183

11184

11185

11186

11187

11188

11189

11190

11191

11192

11193

11194

11195

11196

11197

11198

11199

11200

11201

11202

11203

11204

11205

11206

11207

11208

11209

11210

11211

11212

11213

11214

11215

11216

11217

11218

11219

11220

11221

11222

11223

11224

11225

11226

11227

11228

11229

11230

11231

11232

11233

11234

11235

11236

11237

11238

11239

11240

11241

11242

11243

11244

11245

11246

11247

11248

11249

11250

11251

11252

11253

11254

11255

11256

11257

11258

11259

11260

11261

11262

11263

11264

11265

11266

11267

11268

11269

11270

11271

11272

11273

11274

11275

11276

11277

11278

11279

11280

11281

11285

11286

11287

11288

11298

11351

11352

11403

11404

11439

11440

11441

11442

11443

11444

11446

11447

11448

11711

11712

11757

11772

11784

11785

11793

11794

11795

11810

11811

11812

11813

11814

11815

11816

12077

12078

12079

12080

12101

12102

12103

12105

12106

12107

12108

12110

12112

12113

12114

12115

12173

12174

12175

12176

12177

12185

12190

12191

12195

12203

12204

12205

12206

12207

12208

12209

12210

12211

12225

12234

12235

12236

12237

12241

12268

12269

12270

12271

12272

12273

12274

12275

12276

12277

12285

12286

12306

12309

12310

12311

12313

12317

12337

12342

12359

13696

13699

13701

13707

13709

13716

13801

13868

13871

13877

13879

14187

14422

14423

14425

14648

14657

15444

15668

15669

15671

15672

15673

15674

15675

15677

15774

15775

15776

15777

15778

15784

15787

15788

15789

15791

15852

15865

15866

15876

15930

15951

15952

15953

15955

15984

16377

lie


-------
16378

16382

16386

16387

16388

16389

16390

16391

16392

16393

16394

16395

16396

16397

16398

16399

16400

16401

16418

16448

16452

16453

16454

16455

16456

16457

16458

16459

16460

16462

16463

16464

16465

16466

16467

16468

16476

16477

16478

16480

16481

16482

16483

16484

16485

16486

16500

16978

16979

16980

16981

16982

17047

17048

17050

17051

17229

17230

17232

17235

17236

17252

17253

17256

17272

17288

17301

17302

17311

17312

17313

17326

17392

17394

17410

17394

17412

17413

17414

17415

17416

17417

17418

17419

17420

17421

17422

17423

17424

17425

17426

17427

17428

17429

17430

17431

17432

17433

17434

17435

17436

17437

17438

17439

17440

17441

17442

17443

17444

17446

17447

17448

17449

17450

17451

17452

17453

17454

17455

17456

17458

17459

17460

17461

17462

17464

17467

17468

17469

17474

17475

17476

17477

17478

17479

17480

17481

17482

17483

17484

17485

17487

17488

17492

17493

17494

17495

17497

17498

17499

17500

17501

17502

17503

17504

17505

17506

17507

17508

17509

17510

17511

17512

17513

17514

17515

17516

17517

17518

17519

17520

17521

17522

17523

17524

17525

17526

17527

17528

17529

17530

17531

17532

17533

17534

17535

17536

17537

17538

17539

17540

17541

17542

17543

17544

17545

17546

17547

17548

17549

17550

17551

17552

17553

17554

17555

17556

17557

17558

17559

17560

17561

17562

17563

17564

17565

17566

17567

17568

17569

17570

17571

17572

17573

17574

17575

17576

17577

17578

17579

17580

17581

17582

17583

17584

17585

17586

17587

17588

17589

17590

17591

17592

17593

17594

17595

17596

17597

17598

17599

17600

17601

17602

17603

17604

17605

17606

17607

17609

17610

17611

17612

17613

17614

17615

17616

17617

17618

17619

17630

17631

17632

17633

17634

17635

17636

17642

17643

17644

17645

17646

17647

17664

17665

17666

17667

17668

17669

17670

17671

17672

17673

17858

17859

17860

17861

17864

17865

17954

17955

17956

17957

17958

17959

17960

17961

17962

17963

17964

17965

17966

17967

17968

17969

17970

17971

17972

17976

17977

17978

17979

17980

17982

17983

17984

17985

17986

18009

18053

18054

18055

18056

18057

18058

18059

18060

18061

18062

18063

18066

18067

18068

18116

18119

18123

18134

18137

18153

18157

18158

18160

18174

18176

18185

18188

18191

18192

18193

18194

18195

18196

18197

18198

18199

18200

18201

18202

18203

18204

18205

18206

18207

18208

18209

18210

18211

18212

18213

18214

18215

18216

18217

18218

18219

18220

18221

18222

18223

18224

18225

18226

18227

18228

18229

18230

18231

18232

18233

18234

18235

18236

18237

18238

18239

18240

18241

18242

18243

18244

18245

18246

18247

18254

18259

18261

18262

18263

18265

18266

18268

18269

18270

18272

18274

18276

18277

18278

18329

18330

18331

18332

18333

18334

18335

18336

18337

18338

18341

18346

18353

18354

18356

18360

18451

18452

18453

18454

18455

18456

18457

18458

18459

18460

18463

18465

18467

18468

18472

18475

18476

18536

18577

18580

18581

18582

18583

18584

18585

18625

18626

18627

18628

18630

18632

18633

18645

18647

18649

18654

18655

18677

18684

18702

18709

18710

18711

18714

18729

18730

18731

18732

18733

18734

18735

18736

18737

18738

18739

18740

18741

18742

18752

18753

18754

18755

18756

18757

18758

18768

18769

18770

18771

18772

18773

18774

18775

18777

18778

18779

18778

18783

18786

18787

18788

18790

18791

18792

18793

777


-------
18794

18795

18796

18803

18804

18805

18806

18807

18808

18809

18810

18811

18812

18813

18814

18816

18817

18818

18819

18821

18822

18829

18830

18832

18833

18837

18838

18839

18840

18843

18844

18845

18846

18852

18853

18854

18855

18856

18857

18858

18859

18860

18861

18862

18885

18886

18888

18889

18890

18891

18892

18902

18903

18904

18905

18906

18923

18931

18941

18942

18943

18948

18981

18991

19017

19018

19019

19020

19021

19022

19053

19057

19126

19127

19128

19129

19130

19131

19135

19146

19147

19151

19152

19157

19169

19170

19171

19185

19192

19263

19267

19268

19269

19270

19272

19288

19289

19291

19292

19297

19298

19299

19303

19304

19310

19311

19312

19313

19314

19315

19316

19317

19318

19319

19321

19322

19323

19324

19325

19326

19327

19329





















Total:

3,386

Table 9A-8. Persons of Faith

11377

11378

11379

11380

11383

11384

11386

11387

11388

11389

11391

11392

11394

11395

11413

11414

11415

11416

11417

11421

11422

11423

11424

11425

11427

11532

11536

11882

11884

11885

11886

11887

11888

11996

11997

11998

12000

12001

12004

12065

12066

12068

12090

12093

12129

12132

12171

12417

12464

12719

12836

13537

13640

14027

16094

16095

16096

16097

16098

16099

16101

16102

16114

16115

16116

16126

16166

16213

16225

16231

16311

16323

16352

16555

16556

16557

16558

16559

16561

16564

16569

16584

16585

16586

16588

16589





















Total:

86

Table 9A-9. Green Peace

5911

5913

6639

10646

10651

10758

10766

10767

10811

10813

10847

10848

10849

10850

10851

10852

10853

10854

10855

10856

10857

10858

10859

10860

10861

10862

10869

10870

10871

10872

10873

10874

10875

10876

10877

10878

10879

10880

10881

10882

10883

10884

10885

10886

10887

10888

10889

10890

10891

10892

10893

10894

10895

10896

10897

10898

10899

10900

10901

10903

10904

10905

10907

10908

10909

10910

10911

10912

10913

10915

10916

10917

10918

10919

10920

10921

10922

10923

10924

10925

10926

10927

10928

10929

10930

10931

10932

10933

10934

10935

10936

10937

10938

10939

10940

10941

10945

10946

10947

10948

10949

10950

10951

10952

10953

10954

10955

10956

10957

10958

10959

10960

10961

10962

10963

10964

10965

10966

10967

10968

10969

10970

10971

10972

10973

10974

10975

10976

10977

10978

10979

10980

10981

10982

10983

10984

10985

10986

10988

10989

10990

10991

10992

10993

10994

10995

10996

10995

10998

10999

11000

11001

11002

11003

11004

11005

11006

11007

11008

11009

11010

11011

11012

11013

11014

11015

11016

11017

11018

11019

11020

11021

11022

11023

11024

11025

11026

11027

11028

11029

11030

11031

11032

11033

11034

11035

11036

11037

11038

11039

11040

11041

11042

11043

11044

11045

11046

11047

11048

11049

11050

11051

11052

11054

778


-------
11055

11057

11058

11059

11060

11061

11062

11063

11068

11069

11070

11071

11072

11073

11074

11075

11076

11077

11078

11079

11080

11081

11088

11089

11090

11091

11092

11093

11094

11095

11097

11098

11099

11100

11101

11102

11103

11709

12625

12674

12890

13052

14001

14002

14246







Total:

249

Table 9A-10. Full Support

16177

16220

16242

16319

17151

18659

18665

18667

Total:

8

Table 9A-11. League of Conservation Voters

5465

9382

Total:

2

Table 9A-12. Natural Resources Council of Maine

4077

4078

4079

4080

4081

4082

4083

4084

4085

4086

4195

4197

4198

4199

4201

4202

4203

4204

4205

4206

4207

4208

4209

4213

4239

4240

4267

4269

4270

4271

4272

4273

4374

4462

4554

5146

5163

5432

6635

12287

12355

12356

13697

14669

15676

15926

16439

16440

16441

16442

16443

16444

16445

16446

16447

16449

16451

16470

16471

16472

16473

16474

16475

16479

16541

16545

17231

17284

17285

17286

17287

17314

17322

17325





















Total:

74

Table 9A-13. Natural Resources Defense Council (NRDC)

12645

12875

13084

13085

13089

13090

13091

13092

13093

13097

13100

13101

13105

13106

13148

13150

13190

13191

13192

13193

13255

13256

13264

13265

13266

13272

13273

13299

13300

13301

13331

13332

13336

13337

13347

13348

13349

13350

13351

13352

13354

13355

13356

13357

13359

13360

13361

13362

13366

13367

13368

13369

13370

13371

13372

13373

13374

13376

13377

13378

13379

13384

13386

13387

13388

13389

13390

13391

13392

13393

13394

13395

13396

13397

13401

13406

13407

13408

13412

13413

13414

13415

13416

13417

13418

13427

13428

13429

13430

13431

13444

13445

13446

13447

13459

13464

13465

13468

13496

13497

13508

13509

13510

13511

13517

13536

13538

13540

13541

13547

13564

13566

13569

13570

13572

13573

13603

13604

13605

13606

13609

13611

13612

13613

13614

13621

13622

13623

13624

13629

13630

13631

13632

13635

13639

13644

13672

13673

13674

13690

13691

13693

13694

13796

13797

13798

13799

13798

14019

14025

14033

14046

14047

14071

14077

14122

14135

14139

14140

14144

14149

14160

14170

14171

14202

14394

14721

14804

15173

15197

15281

15285

15321

15339

15341

15914

16522

16525

17144

17145

17149

17150

18396

18398

18403

18407

18412

18635

18636

18913





779


-------
Total:

190

Table 9A-14. National Wildlife Federation (NWF)

3852

3860

3868

3882

3883

3894

3899

4087

4088

4089

4090

4091

4092

4093

4094

4095

4096

4097

4098

4154

4155

4156

4157

4158

4159

4160

4161

4163

4164

4165

4166

4210

4211

4212

4214

4215

4237

4297

4366

4367

4368

4369

4370

4371

4372

4373

4375

4376

4401

4411

4434

4439

4440

4441

4448

4449

4494

4495

4496

4502

4525

4526

4535

4536

4541

4544

4545

4563

4565

4571

4580

4600

4601

4607

4615

4618

4627

4642

4644

4645

4665

4666

4667

4668

4672

4674

4678

4688

4689

4690

4697

4732

4826

4827

4923

4925

4932

4959

4971

5001

5002

5003

5004

5019

5020

5021

5022

5023

5024

5025

5056

5057

5068

5076

5077

5078

5084

5102

5103

5104

5120

5140

5141

5176

5184

5242

5243

5244

5246

5265

5266

5281

5282

5286

5294

5303

5304

5317

5319

5320

5329

5428

5429

5430

5431

5433

5434

5433

5436

5437

5438

5439

5440

5441

5442

5443

5444

5445

5451

5469

5470

6177

6694

9710

9976

10001

10010

10028

11056

11138

11445

11533

12100

12109

12111

12142

12178

12184

12186

12187

12193

12216

12289

12299

12301

12308

12332

12341

12344

13698

13710

13803

13884

13885

13886

13887

13889

13890

13891

13892

13893

13894

13895

13896

13897

13898

13899

13900

13901

13903

13904

13905

13906

13909

13910

13911

13912

13913

13914

13915

13916

13917

13918

13920

13921

13922

13924

13925

13926

13927

13928

13929

13930

13931

13933

13934

13935

13936

13937

13938

13939

13940

13941

13942

13943

13944

13945

13946

13947

13948

13949

13950

13951

13952

13953

13954

13955

13956

13957

13958

13959

13960

13962

13963

13964

13984

13985

13986

13987

13988

13989

13990

13991

13992

13993

13994

13995

13996

13997

13998

13999

14000

14421

14426

14435

14436

14437

14462

14463

14464

14465

14466

14467

14468

14469

14470

14471

14472

14473

14474

14475

14476

14477

14479

14502

14505

14510

14661

14665

15402

15433

15434

15435

15436

15437

15438

15440

15441

15442

15443

15445

15446

15514

15515

15516

15517

15518

15548

15549

15550

15551

15552

15557

15558

15559

15786

15813

15920

15931

15932

15934

15956

15959

15961

16380

16384

16551

17234

17324

17653

19606

19612

















Total:

352

Table 9A-15. Ohio Citizens Action

17239

17240

17245

17257

17258

17259

17260

17261

17262

17263

17264

17266

18309

18310

18312

18314

18318

18321

18322

18328

18373

18374

18378

18380

18383

18384

18386

18387

18393

18402

18404

18408

18542

18549

18564

18602

18603

18605

18607

18617

18619

18660

18681

18848

18863

18864

18866

18868

18870

18872

18873

18876

18877

19005

19007

19034

19038

19197

19200

19208

19218

19219

19222

19230

19231

19235

19243

19251

19254

19520

19522

19526

780


-------
19533

19535

19542

19545

19547

19548

19551

19555

19558

19587





Total:

82

Table 9A-16. Our Families

4149

5214

5241

5576

5648

7063

7064

7065

7066

7067

7068

7069

7070

7071

7072

7073

7074

7075

7076

7089

7090

7091

7092

7093

7094

7095

7096

7097

7098

7099

7100

7101

7102

7103

7104

7105

7106

7107

7108

7109

7110

7111

7112

7113

7114

7115

7116

7117

7118

7119

7120

7121

7122

7123

7135

7136

7245

7246

7247

7248

7249

7250

7251

7252

7253

7257

7258

7259

7260

7261

7262

7263

7264

7265

7266

7267

7268

7269

7270

7271

7272

7273

7274

7275

7276

7277

7278

7279

7280

7281

7282

7283

7284

7285

7286

7287

7288

7289

7290

7291

7292

7293

7294

7295

7296

7297

7298

7299

7300

7301

7306

7307

7308

7309

7310

7311

7312

7313

7314

7315

7316

7317

7318

7319

7320

7321

7322

7323

7324

7325

7326

7327

7328

7329

7330

7331

7332

7333

7334

7335

7336

7337

7338

7339

7340

7341

7342

7341

7344

7359

7360

7361

7362

7363

7364

7365

7366

7367

7368

7369

7370

7371

7372

7373

7374

7375

7376

7377

7378

7379

7380

7381

7382

7383

7384

7385

7386

7387

7388

7389

7390

7391

7392

7393

7394

7395

7396

7397

7398

7399

7400

7401

7402

7403

7404

7405

7406

7407

7408

7409

7410

7411

7412

7413

7414

7415

7416

7417

7418

7419

7420

7421

7422

7423

7424

7425

7426

7427

7428

7429

7430

7431

7432

7433

7434

7435

7436

7437

7438

7439

7440

7441

7442

7443

7444

7445

7446

7447

7448

7449

7450

7451

7452

7453

7454

7455

7456

7457

7458

7459

7460

7461

7462

7463

7464

7465

7466

7467

7468

7469

7470

7471

7472

7473

7474

7475

7476

7477

7478

7479

7480

7481

7482

7483

7484

7485

7486

7487

7488

7489

7490

7491

7492

7493

7494

7495

7535

7536

7537

7540

7541

7542

7543

7544

7545

7546

7547

7548

7549

7550

7551

7552

7553

7554

7555

7556

7557

7558

7559

7560

7561

7562

7563

7564

7565

7566

7567

7568

7569

7570

7571

7572

7573

7574

7575

7576

7577

7578

7579

7580

7581

7632

7633

7634

7635

7636

7637

7638

7639

7640

7641

7642

7643

7644

7645

7646

7647

7648

7649

7650

7651

7652

7660

7672

9102

9158

9325

9349

9505

9508

9510

9649

9730

9736

9737

9742

9807

10065

10160

11878

12406

12803

13617























Total:

385

Table 9A-17. Physicians for Social Responsibility

13107

13149

13315

13317

13322

13365

13375

13383

13411

13492

13493

13494

13555

13575

13578

13580

13600

13627

13636

13692

13695

14123

14132

15220

15227

15229

15250

15251

15253

15286

15320

15322

15345

15347

15348

15349

781


-------
15350

15351

15495

15496

15526

15527

15528

15529

15530

15531

15533

15534

15831

16006

16026

16209

















Total:

52

Table 9A-18. Salsa Labs

7129

9575

9733

10172

10194

10200

10201

10213

10214

10215

10659

10736

11299

11359

11364

11366

11368

11370

11371

11390

11402

11410

11411

11418

11419

11546

11547

11549

11550

11552

11554

11555

11556

11557

11558

11559

11560

11561

11562

11563

11564

11565

11566

11567

11569

11570

11571

11572

11573

11574

11576

11577

11578

11580

11581

11582

11583

11584

11585

11586

11588

11589

11590

11591

11592

11639

11640

11641

11642

11643

11651

11659

11660

11661

11665

11666

11702

11725

11763

11764

11790

11791

11832

11834

11835

11836

11837

11840

11841

11842

11858

11860

11865

11877

11891

11892

11894

11901

11902

11903

11904

11905

11914

11916

11917

11924

11927

11928

11935

11963

11967

11999

12002

12023

12049

12094

12151

12284

12416

12421

12438

12440

12441

12442

12443

12448

12449

12450

12457

12463

12466

12468

12474

12495

12507

12512

12519

12537

12539

12540

12551

12556

12573

12574

12584

12599

12609

12599

12624

12644

12654

12677

12678

12712

12714

12717

12718

12727

12769

12770

12772

12791

12802

12812

12815

12828

12891

12892

12894

12901

12979

13194

13326

13353

13382

13385

13400

13404

13435

13442

13443

13458

13475

13477

13483

13563

13568

13576

13579

13601

13615

14028

14029

14051

14052

14053

14054

14055

14056

14057

14058

14059

14060

14061

14063

14064

14067

14068

14074

14079

14080

14081

14082

14088

14097

14098

14099

14105

14108

14112

14113

14114

14121

14124

14136

14137

14150

14153

14154

14156

14157

14173

14174

14175

14176

14177

14181

14182

14183

14185

14190

14206

14207

14208

14209

14210

14211

14212

14213

14214

14215

14216

14217

14218

14219

14220

14221

14222

14223

14224

14225

14229

14231

14232

14234

14236

14237

14238

14240

14241

14242

14244

14245

14247

14248

14249

14250

14251

14252

14253

14254

14260

14261

14262

14263

14264

14267

14268

14271

14272

14274

14275

14301

14309

14310

14311

14312

14313

14314

14315

14316

14317

14318

14319

14325

14327

14328

14329

14330

14331

14332

14333

14334

14335

14336

14337

14338

14339

14340

14341

14342

14343

14344

14346

14348

14349

14350

14354

14358

14359

14365

14366

14367

14376

14377

14378

14379

14380

14381

14382

14386

14388

14395

14397

14398

14399

14400

14402

14403

14406

14407

14408

14409

14410

14411

14416

14429

14430

14440

14451

14460

14461

14486

14521

14522

14523

14524

14525

14526

14527

14528

14529

14530

14531

14532

14533

14534

14535

14536

14537

14538

14539

14540

14678

14725

14726

14763

14764

14765

14766

14792

14794

14796

14797

14798

14799

14800

14801

14806

14810

14811

14812

14833

14834

14835

14836

14837

14838

14839

14840

14842

14847

14848

14849

14850

14851

14852

14854

14904

15007

15009

15011

15018

15021

15022

15023

15043

15045

15046

15048

15049

15052

15053

15054

15056

15057

15058

15059

15061

15080

15082

15164

15170

15172

15174

15176

15212

15214

15217

15219

15221

15224

15225

15249

15273

15283

782


-------
15335

15337

15344

15403

15408

15425

15448

15449

15450

15458

15460

15465

15483

15484

15485

15486

15487

15488

15489

15490

15491

15492

15519

15520

15523

15553

15570

15682

15685

15686

15687

15688

15689

15690

15691

15790

15892

15893

15910

15911

15912

15949

16005

16007

16008

16009

16010

16012

16013

16014

16024

16025

16027

16028

16030

16031

16032

16046

16047

16052

16053

16055

16075

16164

16165

16226

16227

16229

16230

16233

16236

16237

16238

16281

16297

16304

16306

16320

16515

16516

16518

16526

16527

16538

16539

16540

16552

16560

16568

16591

17073

17089

17142

17143

17148

17152

17374

17404

18280

18281

18282

18283

18284

18285

18289

18290

18291

18292

18293

18294

18295

18296

18297

18298

18299

18300

18303

18304

18305

18307

18308

18311

18315

18316

18317

18320

18323

18324

18325

18326

18327

18371

18372

18375

18376

18375

18381

18382

18385

18388

18389

18390

18391

18392

18394

18395

18397

18399

18400

18405

18409

18410

18411

18508

18509

18510

18512

18513

18514

18515

18516

18517

18518

18519

18520

18521

18522

18523

18524

18525

18526

18527

18528

18529

18530

18532

18533

18534

18535

18537

18543

18544

18545

18550

18555

18560

18561

18563

18567

18569

18573

18574

18599

18600

18601

18604

18606

18608

18609

18610

18611

18612

18613

18614

18618

18624

18634

18637

18673

18674

18675

18687

18701

18704

18744

18760

18761

18762

18763

18764

18765

18865

18875

18895

18896

18908

18909

18910

18911

18912

18915

18916

18919

18920

18921

18922

18938

18939

18946

18947

18949

18950

18951

18952

18953

18954

18956

18958

18967

18968

18970

19006

19008

19011

19012

19014

19015

19035

19036

19037

19188

19189

19193

19194

19201

19204

19207

19232

19234

19237

19245

19252

19253

19525

19530

19552

19553

19583

19585

19586

















Total:

736

Table 9A-19. Sierra Club

3106

3107

3108

3109

3110

3111

3112

3113

3114

3115

3116

3117

3118

3119

3120

3183

3187

3189

3190

3191

3192

3193

3194

3195

3196

3197

3198

3200

3201

3204

3205

3206

3207

3209

3210

3211

3212

3214

3216

3218

3219

3221

3257

3342

3343

3344

3345

3346

3347

3348

3351

3352

3354

3355

3357

3363

3368

3369

3376

3377

3387

3394

3395

3396

3421

3422

3423

3445

3446

3447

3448

3449

3450

3451

3475

3479

3480

3481

3482

3483

3484

3485

3486

3487

3507

3589

3590

3591

3690

3691

3705

3748

3749

3752

3753

3754

3755

3770

3771

3796

3800

3801

3803

3804

3815

3816

3824

3825

3826

3831

3832

3837

3844

3850

3851

3857

3858

3867

3872

3873

3874

3880

3881

3892

3896

3898

3901

3902

3905

3906

3911

3912

3914

3916

3917

3918

3928

3929

3930

3931

3932

3940

4050

4051

4052

4054

4055

4054

4061

4062

4064

4066

4068

4069

4070

4072

4073

4130

4131

4132

4133

4134

4135

4136

4151

4152

4153

4344

4363

4364

4365

4523

4524

4557

4671

4684

4706

4718

4730

4770

783


-------
4771

4790

4807

4834

4846

4858

4870

4882

4894

4906

4918

4944

4956

4969

4989

5013

5040

5055

5071

5091

5112

5127

5147

5161

5178

5198

5219

5231

5251

5263

5284

5299

5314

5334

5357

5370

5382

5394

5406

5422

5468

5482

4772

4773

4774

4775

4776

4777

4778

4779

4780

4781

4782

4791

4792

4793

4794

4799

4800

4801

4802

4803

4805

4806

4813

4814

4815

4816

4817

4828

4829

4830

4831

4832

4833

4835

4836

4837

4838

4839

4840

4841

4842

4843

4844

4845

4847

4848

4849

4850

4851

4852

4853

4854

4855

4856

4857

4859

4860

4861

4862

4863

4864

4865

4866

4867

4868

4869

4871

4872

4873

4874

4875

4876

4877

4878

4879

4880

4881

4883

4884

4885

4886

4887

4888

4889

4890

4891

4892

4893

4895

4896

4897

4898

4899

4900

4901

4902

4903

4904

4905

4907

4908

4909

4910

4911

4912

4913

4914

4915

4916

4917

4919

4929

4934

4935

4936

4937

4938

4939

4940

4941

4943

4945

4946

4947

4948

4949

4950

4951

4952

4953

4954

4955

4957

4958

4960

4961

4962

4963

4964

4965

4966

4967

4968

4970

4974

4975

4976

4977

4978

4979

4980

4981

4987

4988

4990

4991

4992

4996

4997

4998

5008

5009

5010

5011

5012

5015

5017

5018

5032

5033

5034

5035

5036

5037

5038

5039

5041

5043

5044

5045

5046

5047

5048

5049

5050

5051

5052

5058

5059

5060

5061

5062

5063

5064

5066

5067

5069

5070

5072

5073

5074

5075

5079

5080

5081

5083

5088

5089

5090

5092

5093

5094

5095

5096

5099

5100

5101

5109

5110

5111

5113

5114

5115

5116

5117

5118

5119

5121

5123

5124

5126

5128

5129

5130

5131

5132

5133

5134

5135

5136

5137

5139

5148

5149

5150

5151

5152

5153

5154

5155

5156

5157

5160

5164

5165

5166

5167

5168

5169

5170

5171

5172

5173

5177

5179

5180

5181

5185

5186

5187

5188

5189

5194

5195

5197

5199

5200

5201

5202

5208

5209

5210

5211

5213

5217

5218

5220

5221

5222

5223

5224

5225

5226

5227

5228

5229

5230

5232

5233

5234

5235

5236

5237

5238

5239

5240

5249

5250

5252

5253

5254

5255

5256

5257

5258

5259

5260

5261

5262

5270

5271

5272

5273

5274

5275

5276

5277

5278

5279

5283

5285

5287

5288

5289

5290

5291

5292

5293

5296

5297

5298

5300

5301

5302

5306

5307

5308

5309

5310

5311

5312

5313

5315

5316

5322

5323

5324

5325

5326

5327

5328

5332

5333

5335

5336

5337

5338

5339

5340

5341

5342

5343

5344

5347

5358

5359

5358

5361

5362

5363

5364

5365

5366

5367

5368

5371

5372

5373

5374

5375

5376

5377

5378

5379

5380

5381

5383

5384

5385

5386

5387

5388

5389

5390

5391

5392

5393

5395

5396

5397

5398

5399

5400

5401

5402

5403

5404

5405

5407

5408

5409

5410

5411

5412

5417

5418

5419

5420

5421

5423

5424

5425

5426

5427

5461

5462

5463

5464

5466

5467

5471

5472

5473

5474

5475

5476

5477

5478

5479

5480

5481

5483

5484

5485

5486

5487

5488

5489

5490

5491

5492

5493

784


-------
5494

5506

5520

5532

5544

5556

5571

5584

5596

5608

5620

5632

5644

5657

5669

5681

5694

5719

5731

5743

5759

5771

5783

5795

5807

5822

5834

5851

5872

5884

5896

5908

5922

5934

5946

5958

5970

5982

5994

6006

6019

6031

5495

5496

5497

5498

5499

5500

5501

5502

5503

5504

5505

5507

5508

5509

5510

5511

5512

5513

5514

5515

5516

5519

5521

5522

5523

5524

5525

5526

5527

5528

5529

5530

5531

5533

5534

5535

5536

5537

5538

5539

5540

5541

5542

5543

5545

5546

5547

5548

5549

5550

5551

5552

5553

5554

5555

5557

5558

5561

5563

5564

5565

5566

5567

5568

5569

5570

5572

5573

5574

5575

5577

5578

5579

5580

5581

5582

5583

5585

5586

5587

5588

5589

5590

5591

5592

5593

5594

5595

5597

5598

5599

5600

5601

5602

5603

5604

5605

5606

5607

5609

5610

5611

5612

5613

5614

5615

5616

5617

5618

5619

5621

5622

5623

5624

5625

5626

5627

5628

5629

5630

5631

5633

5634

5635

5636

5637

5638

5639

5640

5641

5642

5643

5645

5646

5647

5649

5650

5651

5652

5653

5654

5655

5656

5658

5659

5660

5661

5662

5663

5664

5665

5666

5667

5668

5670

5671

5672

5673

5674

5675

5676

5677

5678

5679

5680

5682

5683

5684

5685

5686

5687

5688

5689

5690

5692

5693

5695

5696

5697

5698

5699

5700

5714

5715

5716

5717

5718

5720

5721

5722

5723

5724

5725

5726

5727

5728

5729

5730

5732

5733

5734

5735

5736

5737

5738

5739

5740

5741

5742

5744

5745

5746

5747

5748

5749

5754

5755

5756

5757

5758

5760

5761

5762

5763

5764

5765

5766

5767

5768

5769

5770

5772

5773

5774

5775

5776

5777

5778

5779

5780

5781

5782

5784

5785

5786

5787

5788

5789

5790

5791

5792

5793

5794

5796

5797

5798

5799

5800

5801

5802

5803

5804

5805

5806

5808

5809

5810

5811

5812

5813

5816

5817

5818

5819

5821

5823

5824

5825

5826

5827

5828

5829

5830

5831

5832

5833

5835

5836

5837

5841

5842

5843

5844

5845

5846

5849

5850

5853

5862

5863

5864

5865

5866

5867

5868

5869

5870

5871

5873

5874

5875

5876

5877

5878

5879

5880

5881

5882

5883

5885

5886

5885

5888

5889

5890

5891

5892

5893

5894

5895

5897

5898

5899

5900

5901

5902

5903

5904

5905

5906

5907

5909

5910

5912

5914

5915

5916

5917

5918

5919

5920

5921

5923

5924

5925

5926

5927

5928

5929

5930

5931

5932

5933

5935

5936

5937

5938

5939

5940

5941

5942

5943

5944

5945

5947

5948

5949

5950

5951

5952

5953

5954

5955

5956

5957

5959

5960

5961

5962

5963

5964

5965

5966

5967

5968

5969

5971

5972

5973

5974

5975

5976

5977

5978

5979

5980

5981

5983

5984

5985

5986

5987

5988

5989

5990

5991

5992

5993

5995

5996

5997

5998

5999

6000

6001

6002

6003

6004

6005

6007

6009

6010

6011

6012

6013

6014

6015

6016

6017

6018

6020

6021

6022

6023

6024

6025

6026

6027

6028

6029

6030

6032

6033

6034

6035

6036

6037

6038

6039

6040

6041

6042

785


-------
6043

6056

6068

6080

6092

6104

6645

6657

7130

7144

7156

7168

7180

7192

7594

7606

7618

7630

7684

7696

7708

7720

7732

7744

7757

7769

7781

7793

7805

7817

7830

7842

7854

7867

7879

7891

7903

7915

7927

7939

7951

7963

6044

6045

6046

6047

6048

6049

6050

6051

6052

6053

6055

6057

6058

6059

6060

6061

6062

6063

6064

6065

6066

6067

6069

6070

6071

6072

6073

6074

6075

6076

6077

6078

6079

6081

6082

6083

6084

6085

6086

6087

6088

6089

6090

6091

6093

6094

6095

6096

6097

6098

6099

6100

6101

6102

6103

6105

6106

6107

6108

6109

6110

6111

6641

6642

6643

6644

6646

6647

6648

6649

6650

6651

6652

6653

6654

6655

6656

6658

6659

6660

6661

6662

6663

7124

7125

7126

7127

7128

7131

7132

7133

7134

7137

7138

7139

7140

7141

7142

7143

7145

7146

7147

7148

7149

7150

7151

7152

7153

7154

7155

7157

7158

7159

7160

7161

7162

7163

7164

7165

7166

7167

7169

7170

7171

7172

7173

7174

7175

7176

7177

7178

7179

7181

7182

7183

7184

7185

7186

7187

7188

7189

7190

7191

7193

7194

7195

7196

7197

7345

7589

7590

7591

7592

7593

7595

7596

7597

7598

7599

7600

7601

7602

7603

7604

7605

7607

7608

7609

7610

7611

7612

7613

7614

7615

7616

7617

7619

7620

7621

7622

7623

7624

7625

7626

7627

7628

7629

7631

7656

7657

7676

7677

7678

7679

7680

7681

7682

7683

7685

7686

7687

7688

7689

7690

7691

7692

7693

7694

7695

7697

7698

7699

7700

7701

7702

7703

7704

7705

7706

7707

7709

7710

7711

7712

7713

7714

7715

7716

7717

7718

7719

7721

7722

7723

7724

7725

7726

7727

7728

7729

7730

7731

7733

7734

7735

7736

7737

7738

7739

7740

7741

7742

7743

7745

7746

7748

7749

7750

7751

7752

7753

7754

7755

7756

7758

7759

7758

7761

7762

7763

7764

7765

7766

7767

7768

7770

7771

7772

7773

7774

7775

7776

7777

7778

7779

7780

7782

7783

7784

7785

7786

7787

7788

7789

7790

7791

7792

7794

7795

7796

7797

7798

7799

7800

7801

7802

7803

7804

7806

7807

7808

7809

7810

7811

7812

7813

7814

7815

7816

7818

7819

7820

7821

7822

7823

7824

7825

7826

7827

7829

7831

7832

7833

7834

7835

7836

7837

7838

7839

7840

7841

7843

7844

7845

7846

7847

7848

7849

7850

7851

7852

7853

7855

7856

7857

7858

7860

7861

7862

7863

7864

7865

7866

7868

7869

7870

7871

7872

7873

7874

7875

7876

7877

7878

7880

7881

7882

7883

7884

7885

7886

7887

7888

7889

7890

7892

7893

7894

7895

7896

7897

7898

7899

7900

7901

7902

7904

7905

7906

7907

7908

7909

7910

7911

7912

7913

7914

7916

7917

7918

7919

7920

7921

7922

7923

7924

7925

7926

7928

7929

7930

7931

7932

7933

7934

7935

7936

7937

7938

7940

7941

7942

7943

7944

7945

7946

7947

7948

7949

7950

7952

7953

7954

7955

7956

7957

7958

7959

7960

7961

7962

7964

7965

7966

7967

7968

7969

7970

7971

7972

7973

7974

786


-------
7976

7989

8001

8013

8025

8037

8049

8061

8073

8085

8097

8109

8121

8133

8145

8157

8169

8181

8193

8205

8217

8229

8241

8253

8267

8279

8292

8306

8318

8330

8342

8354

8366

8378

8390

8402

8414

8426

8439

8452

8464

8476

7977

7978

7979

7980

7981

7982

7983

7984

7985

7986

7988

7990

7991

7992

7993

7994

7995

7996

7997

7998

7999

8000

8002

8003

8004

8005

8006

8007

8008

8009

8010

8011

8012

8014

8015

8016

8017

8018

8019

8020

8021

8022

8023

8024

8026

8027

8028

8029

8030

8031

8032

8033

8034

8035

8036

8038

8039

8040

8041

8042

8043

8044

8045

8046

8047

8048

8050

8051

8052

8053

8054

8055

8056

8057

8058

8059

8060

8062

8063

8064

8065

8066

8067

8068

8069

8070

8071

8072

8074

8075

8076

8077

8078

8079

8080

8081

8082

8083

8084

8086

8087

8088

8089

8090

8091

8092

8093

8094

8095

8096

8098

8099

8100

8101

8102

8103

8104

8105

8106

8107

8108

8110

8111

8112

8113

8114

8115

8116

8117

8118

8119

8120

8122

8123

8124

8125

8126

8127

8128

8129

8130

8131

8132

8134

8135

8136

8137

8138

8139

8140

8141

8142

8143

8144

8146

8147

8148

8149

8150

8151

8152

8153

8154

8155

8156

8158

8159

8160

8161

8162

8163

8164

8165

8166

8167

8168

8170

8171

8172

8173

8174

8175

8176

8177

8178

8179

8180

8182

8183

8184

8185

8186

8187

8188

8189

8190

8191

8192

8194

8195

8196

8197

8198

8199

8200

8201

8202

8203

8204

8206

8207

8206

8209

8210

8211

8212

8213

8214

8215

8216

8218

8219

8220

8221

8222

8223

8224

8225

8226

8227

8228

8230

8231

8232

8233

8234

8235

8236

8237

8238

8239

8240

8242

8243

8244

8245

8246

8247

8248

8249

8250

8251

8252

8254

8255

8258

8259

8260

8261

8262

8263

8264

8265

8266

8268

8269

8270

8271

8272

8273

8274

8275

8276

8277

8278

8280

8281

8282

8283

8284

8285

8286

8288

8289

8290

8291

8293

8294

8295

8296

8297

8298

8299

8302

8303

8304

8305

8307

8308

8309

8310

8311

8312

8313

8314

8315

8316

8317

8319

8320

8321

8322

8323

8324

8325

8326

8327

8328

8329

8331

8332

8333

8334

8335

8336

8337

8338

8339

8340

8341

8343

8344

8345

8346

8347

8348

8349

8350

8351

8352

8353

8355

8356

8357

8358

8359

8360

8361

8362

8363

8364

8365

8367

8368

8369

8370

8371

8372

8373

8374

8375

8376

8377

8379

8380

8381

8382

8383

8384

8385

8386

8387

8388

8389

8391

8392

8393

8394

8395

8396

8397

8398

8399

8400

8401

8403

8404

8405

8406

8407

8408

8409

8410

8411

8412

8413

8415

8416

8417

8418

8419

8420

8421

8422

8423

8424

8425

8427

8428

8429

8430

8431

8432

8433

8435

8436

8437

8438

8440

8441

8442

8444

8445

8446

8447

8448

8449

8450

8451

8453

8454

8455

8456

8457

8458

8459

8460

8461

8462

8463

8465

8466

8467

8468

8469

8470

8471

8472

8473

8474

8475

8477

8478

8479

8480

8481

8482

8483

8484

8485

8486

8487

787


-------
8488

8500

8512

8526

8538

8550

8562

8574

8596

8608

8620

8632

8644

8656

8668

8680

8693

8705

8717

8729

8741

8753

8765

8777

8789

8801

8813

8825

8837

8849

8861

8881

8893

8905

8917

8929

8941

8953

8967

8979

8991

9003

8489
8501
8513
8527
8539
8551
8563
8575
8597
8609
8621
8633
8645
8657
8669
8681
8694
8706
8718
8730
8742
8754
8766
8778
8790
8802
8814
8826
8838
8850
8862
8882
8894
8906
8918
8930
8942
8954
8968
8980
8992
9004

8490
8502
8514
8528
8540
8552
8564
8576
8598
8610
8622
8634
8646
8658
8670
8682
8695
8707
8719
8731
8743
8755
8767
8779
8791
8803
8815
8827
8839
8851
8863
8883
8895
8907
8919
8931
8943
8955
8969
8981
8993
9005

8491
8503
8515
8529
8541
8553
8565
8577
8599
8611
8623
8635
8647
8659
8669
8683
8696
8708
8720
8732
8744
8756
8768
8780
8792
8804
8816
8828
8840
8852
8864
8884
8896
8908
8920
8932
8944
8956
8970
8982
8994
9006

8492
8504
8516
8530
8542
8554
8566
8578
8600
8612
8624
8636
8648
8660
8672
8685
8697
8709
8721
8733
8745
8757
8769
8781
8793
8805
8817
8829
8841
8853
8865
8885
8897
8909
8921
8933
8945
8957
8971
8983
8995
9007

8493
8505
8517
8531
8543
8555
8567
8589
8601
8613
8625
8637
8649
8661
8673
8686
8698
8710
8722
8734
8746
8758
8770
8782
8794
8806
8818
8830
8842
8854
8866
8886
8898
8910
8922
8934
8946
8959
8972
8984
8996
9008

8494
8506
8518
8532
8544
8556
8568
8590
8602
8614
8626
8638
8650
8662
8674
8687
8699
8711
8723
8735
8747
8759
8771
8783
8795
8807
8819
8831
8843
8855
8867
8887
8899
8911
8923
8935
8947
8960
8973
8985
8997
9009

8495
8507
8519
8533
8545
8557
8569
8591
8603
8615
8627
8639
8651
8663
8675
8688
8700
8712
8724
8736
8748
8760
8772
8784
8796
8808
8820
8832
8844
8856
8868

8900
8912
8924
8936
8948
8962
8974
8986
8998
9010

8496
8508
8522
8534
8546
8558
8570
8592
8604
8616
8628
8640
8652
8664
8676
8689
8701
8713
8725
8737
8749
8761
8773
8785
8797
8809
8821
8833
8845
8857
8869
8889
8901
8913
8925
8937
8949
8963
8975
8987
8999
9011

8497
8509
8523
8535
8547
8559
8571
8593
8605
8617
8629
8641
8653
8665
8677
8690
8702
8714
8726
8738
8750
8762
8774
8786
8798
8810
8822
8834
8846
8858
8870
8890
8902
8914
8926
8938
8950
8964
8976
8988
9000
9012

8498
8510
8524
8536
8548
8560
8572
8594
8606
8618
8630
8642
8654
8666
8678
8691
8703
8715
8727
8739
8751
8763
8775
8787
8799
8811
8823
8835
8847
8859
8871
8891
8903
8915
8927
8939
8951
8965
8977
8989
9001
9013

8499
8511
8525
8537
8549
8561
8573
8595
8607
8619
8631
8643
8655
8667
8679
8692
8704
8716
8728
8740
8752
8764
8776
8788
8800
8812
8824
8836
8848
8860
8880
8892
8904
8916
8928
8940
8952
8966
8978
8990
9002
9014

788


-------
9015

9016

9017

9018

9019

9020

9021

9023

9024

9025

9026

9027

9028

9029

9030

9031

9032

9033

9034

9035

9036

9037

9038

9039

9040

9041

9042

9043

9044

9045

9046

9047

9048

9049

9050

9051

9052

9053

9054

9055

9056

9057

9058

9059

9060

9061

9062

9063

9064

9065

9066

9067

9068

9069

9070

9071

9073

9074

9075

9076

9077

9078

9079

9080

9081

9082

9083

9084

9085

9086

9087

9088

9089

9090

9091

9092

9093

9094

9095

9096

9097

9098

9099

9100

9101

9103

9104

9105

9106

9107

9108

9109

9110

9111

9113

9114

9115

9116

9117

9119

9120

9121

9122

9123

9124

9125

9126

9127

9128

9129

9130

9129

9132

9133

9134

9135

9136

9137

9138

9139

9140

9141

9142

9143

9144

9145

9146

9147

9148

9149

9150

9151

9152

9153

9155

9156

9157

9160

9161

9162

9163

9164

9165

9166

9167

9168

9169

9170

9171

9173

9218

9219

9220

9286

9287

9288

9289

9290

9291

9292

9293

9294

9295

9296

9297

9345

9347

9348

9350

9351

9352

9353

9354

9355

9356

9357

9358

9359

9360

9361

9362

9363

9364

9365

9366

9367

9368

9369

9370

9371

9372

9373

9374

9375

9377

9378

9379

9380

9381

9383

9384

9385

9386

9387

9388

9389

9390

9391

9392

9393

9394

9395

9396

9397

9398

9399

9400

9401

9402

9403

9404

9405

9406

9407

9408

9409

9410

9411

9412

9413

9414

9415

9416

9417

9418

9419

9420

9421

9422

9423

9424

9425

9426

9427

9428

9429

9448

9466

9467

9468

9484

9497

9499

9507

9509

9512

9514

9523

9616

9728

9729

9731

9734

9735

9739

9740

9741

9745

9746

9747

9748

9750

9751

9752

9753

9771

9772

9773

9774

9775

9776

9777

9778

9779

9780

9781

9782

9783

9784

9785

9786

9787

9788

9789

9791

9792

9793

9794

9795

9796

9797

9798

9799

9800

9801

9802

9803

9804

9850

9851

9852

9853

9856

9857

9861

9865

9905

9906

9908

9910

9911

9912

9913

9914

9915

9916

9917

9918

9922

9923

9924

9925

9926

9927

9928

9929

9930

9935

9936

9937

9938

9945

9948

9949

9950

9952

9954

9955

9956

9957

9960

9961

10030

10031

10032

10033

10034

10035

10036

10037

10038

10039

10040

10042

10043

10044

10045

10046

10047

10048

10049

10050

10051

10052

10053

10054

10055

10056

10057

10058

10059

10060

10061

10062

10063

10064

10066

10067

10068

10069

10070

10071

10072

10073

10074

10075

10076

10077

10078

10079

10080

10081

10082

10083

10084

10085

10086

10087

10088

10089

10090

10091

10092

10093

10094

10095

10096

10097

10098

10101

10102

10103

10105

10107

10108

10111

10112

10113

10123

10124

10127

10129

10130

10131

10132

10133

10134

10135

10136

10137

10138

10139

10140

10141

10142

10143

10144

10145

10146

10147

10148

10149

10150

10151

10152

10153

10154

10155

10156

10157

10158

10159

10161

10162

10163

10164

10168

10171

10173

10174

10175

10176

10177

10178

10179

10180

10181

10183

10184

10185

10186

10187

10188

10189

10190

10191

10192

10193

10195

10196

10197

10198

10199

10202

10203

10204

10205

10206

10207

10208

10209

10210

10211

10212

789


-------
10216

10217

10218

10219

10220

10221

10222

10223

10224

10225

10226

10227

10228

10229

10230

10231

10232

10233

10234

10235

10236

10237

10238

10239

10240

10241

10242

10243

10244

10245

10246

10247

10248

10249

10250

10251

10252

10253

10254

10255

10256

10257

10258

10259

10260

10261

10262

10263

10264

10265

10266

10265

10268

10269

10270

10271

10272

10273

10274

10275

10276

10277

10278

10279

10280

10281

10282

10283

10284

10285

10286

10287

10288

10289

10290

10291

10292

10293

10294

10295

10296

10297

10298

10299

10300

10301

10302

10303

10304

10305

10306

10307

10308

10309

10310

10311

10312

10313

10314

10315

10316

10317

10318

10319

10320

10321

10322

10323

10324

10325

10326

10327

10328

10329

10330

10331

10332

10333

10334

10335

10336

10337

10338

10339

10340

10341

10342

10343

10344

10345

10346

10347

10348

10349

10350

10351

10352

10353

10354

10355

10356

10357

10358

10359

10360

10361

10362

10363

10364

10365

10366

10367

10368

10369

10370

10371

10372

10373

10374

10375

10376

10377

10378

10379

10380

10381

10382

10383

10384

10385

10386

10387

10388

10389

10390

10391

10392

10393

10394

10395

10396

10397

10398

10399

10400

10401

10402

10403

10404

10405

10406

10407

10408

10409

10410

10411

10412

10413

10414

10415

10416

10417

10418

10419

10420

10421

10422

10423

10424

10425

10426

10427

10428

10429

10430

10431

10432

10433

10434

10435

10436

10437

10438

10439

10440

10441

10442

10443

10444

10445

10446

10447

10448

10449

10450

10451

10452

10453

10454

10455

10456

10457

10458

10459

10460

10461

10462

10463

10464

10465

10466

10467

10468

10469

10470

10471

10472

10473

10474

10475

10476

10477

10478

10479

10480

10481

10482

10483

10484

10485

10486

10487

10488

10489

10490

10491

10492

10493

10494

10495

10496

10497

10498

10499

10500

10501

10502

10503

10504

10505

10506

10507

10508

10509

10510

10511

10512

10513

10514

10515

10516

10517

10518

10519

10520

10523

10524

10525

10526

10527

10528

10529

10530

10531

10532

10533

10534

10535

10536

10537

10538

10539

10540

10541

10542

10543

10544

10545

10546

10547

10548

10549

10550

10551

10552

10553

10554

10555

10556

10557

10558

10559

10560

10561

10562

10563

10564

10565

10566

10567

10568

10570

10571

10572

10573

10574

10575

10576

10577

10578

10579

10580

10581

10582

10583

10584

10585

10586

10587

10588

10589

10590

10591

10592

10593

10594

10595

10596

10597

10598

10599

10600

10601

10602

10603

10604

10605

10606

10607

10608

10609

10611

10612

10613

10614

10615

10616

10617

10618

10619

10620

10621

10622

10624

10625

10626

10627

10628

10629

10630

10631

10632

10633

10634

10635

10636

10638

10639

10640

10641

10642

10643

10644

10645

10647

10648

10649

10650

10652

10653

10654

10655

10656

10657

10658

10661

10662

10663

10664

10665

10666

10667

10668

10669

10670

10671

10672

10673

10674

10675

10676

10677

10678

10679

10680

10681

10682

10683

10684

10685

10686

10687

10688

10689

10690

10691

10692

10693

10694

10695

10696

10697

10698

10699

10700

10701

10702

10703

10704

10705

10706

10707

10708

10709

10710

10711

10712

10713

10714

10715

10716

10717

10718

10719

10720

10719

10722

10723

10724

10725

10726

10727

10728

10730

790


-------
10731

10733

10735

10737

10738

10739

10740

10741

10742

10743

10744

10745

10746

10747

10748

10749

10751

10752

10753

10754

10755

10756

10759

10760

10761

10763

10764

10765

10768

10769

10770

10771

10772

10773

10774

10775

10776

10777

10778

10779

10780

10781

10782

10783

10784

10785

10786

10787

10788

10789

10790

10791

10792

10793

10794

10795

10796

10797

10798

10799

10800

10801

10802

10803

10804

10805

10806

10807

10808

10809

10810

10812

10814

10815

10816

10817

10818

10819

10820

10823

10824

10825

10826

10829

10830

10831

10832

10833

10834

10835

10836

10837

10838

10839

10840

10841

10842

10843

10844

10845

10846

10863

10864

10865

10866

10867

10868

10914

11082

11083

11084

11085

11086

11087

11282

11283

11284

11289

11290

11291

11292

11293

11294

11295

11296

11297

11300

11301

11302

11303

11304

11305

11306

11307

11308

11309

11310

11311

11312

11313

11315

11316

11317

11318

11319

11320

11321

11322

11323

11324

11325

11326

11327

11328

11329

11330

11331

11332

11333

11334

11335

11336

11337

11338

11339

11340

11341

11342

11343

11344

11345

11346

11347

11348

11349

11350

11353

11354

11355

11356

11357

11358

11360

11361

11362

11363

11365

11367

11369

11372

11375

11376

11381

11385

11397

11398

11399

11400

11405

11406

11407

11408

11409

11412

11420

11428

11429

11430

11431

11432

11433

11434

11435

11436

11437

11438

11449

11450

11451

11452

11453

11454

11455

11456

11457

11458

11459

11460

11461

11462

11463

11464

11465

11466

11467

11468

11469

11470

11471

11472

11473

11474

11475

11476

11478

11479

11480

11481

11482

11483

11484

11485

11486

11487

11488

11489

11490

11491

11492

11493

11494

11495

11496

11497

11498

11499

11500

11501

11502

11503

11504

11505

11506

11507

11508

11509

11510

11511

11512

11513

11514

11515

11516

11517

11518

11519

11520

11521

11522

11523

11524

11525

11526

11527

11537

11538

11539

11540

11541

11542

11543

11544

11545

11548

11551

11553

11568

11575

11579

11587

11593

11594

11595

11604

11621

11625

11629

11631

11632

11637

11638

11646

11649

11650

11652

11657

11658

11662

11663

11664

11668

11696

11697

11698

11699

11700

11701

11704

11705

11713

11714

11715

11716

11717

11718

11719

11720

11721

11722

11723

11724

11726

11727

11729

11730

11731

11732

11733

11734

11735

11736

11737

11738

11739

11740

11741

11742

11743

11744

11745

11746

11747

11748

11749

11750

11751

11752

11753

11754

11755

11756

11758

11759

11760

11761

11762

11765

11766

11773

11774

11775

11776

11777

11778

11779

11780

11781

11786

11787

11788

11789

11796

11797

11798

11799

11800

11817

11818

11819

11820

11821

11822

11823

11824

11825

11826

11827

11828

11829

11830

11831

11833

11838

11839

11843

11845

11859

11861

11866

11875

11880

11895

11925

11926

11929

11926

11934

11936

11937

11938

11939

11950

11956

11957

11958

11959

11960

11961

11962

11964

11965

11966

11968

11995

12005

12006

12010

12015

12016

12017

12018

12019

12020

12021

12034

12044

12052

12057

12058

12063

12064

12069

12070

12071

12074

12075

12076

12081

12082

12088

12089

12092

12096

12097

12098

12123

12124

12125

12126

12127

12130

12145

12146

12147

12149

12150

12153

12154

12170

12172

12201

12202

12229

12233

791


-------
12239

12240

12242

12243

12244

12245

12246

12247

12248

12249

12250

12251

12263

12266

12279

12280

12282

12385

12386

12387

12388

12389

12390

12391

12392

12393

12394

12395

12396

12397

12398

12399

12400

12401

12403

12404

12407

12408

12410

12412

12413

12414

12415

12419

12420

12422

12423

12424

12426

12427

12428

12429

12432

12433

12434

12435

12436

12437

12444

12445

12446

12447

12451

12452

12453

12454

12455

12456

12458

12465

12469

12470

12471

12472

12473

12475

12476

12477

12478

12479

12480

12481

12482

12483

12484

12485

12486

12487

12488

12489

12490

12491

12492

12493

12494

12496

12497

12498

12499

12500

12501

12502

12514

12515

12516

12517

12522

12523

12524

12527

12528

12529

12530

12531

12538

12541

12542

12543

12544

12545

12549

12550

12552

12553

12554

12555

12557

12558

12559

12575

12576

12577

12578

12579

12580

12581

12582

12583

12585

12586

12587

12588

12590

12591

12592

12593

12594

12595

12596

12597

12598

12600

12601

12602

12603

12604

12605

12606

12607

12608

12610

12611

12612

12613

12614

12616

12623

12631

12632

12633

12634

12635

12636

12637

12638

12640

12641

12642

12643

12646

12647

12655

12656

12657

12658

12659

12660

12666

12667

12668

12669

12670

12671

12672

12680

12681

12688

12689

12690

12691

12692

12693

12694

12695

12696

12697

12698

12699

12700

12701

12702

12703

12713

12721

12726

12728

12729

12730

12731

12732

12733

12734

12735

12736

12737

12738

12739

12740

12741

12742

12743

12744

12745

12746

12747

12748

12749

12750

12751

12752

12753

12754

12771

12773

12774

12775

12776

12777

12778

12779

12781

12782

12783

12784

12785

12786

12787

12788

12789

12790

12792

12804

12805

12806

12808

12809

12810

12811

12813

12817

12818

12819

12820

12821

12822

12823

12824

12825

12826

12827

12829

12830

12831

12832

12833

12834

12835

12837

12838

12839

12840

12841

12842

12843

12844

12845

12846

12847

12848

12849

12850

12851

12852

12853

12854

12855

12856

12857

12858

12859

12860

12861

12862

12863

12864

12865

12866

12867

12868

12869

12870

12871

12872

12873

12874

12876

12877

12878

12879

12880

12882

12883

12884

12885

12893

12895

12897

12898

12899

12900

12902

12903

12904

12905

12906

12907

12908

12909

12910

12911

12912

12913

12914

12915

12916

12917

12918

12919

12920

12921

12922

12923

12924

12925

12926

12927

12928

12929

12930

12931

12932

12933

12934

12935

12936

12935

12938

12939

12940

12941

12942

12943

12944

12945

12946

12947

12972

12973

12974

12975

12978

12980

12981

12982

12983

12984

12985

12986

12990

12993

12997

12998

12999

13000

13001

13002

13003

13004

13009

13011

13012

13013

13014

13015

13016

13017

13018

13019

13020

13021

13022

13023

13024

13025

13026

13027

13028

13030

13031

13032

13033

13034

13035

13036

13037

13038

13039

13040

13041

13042

13043

13044

13045

13046

13047

13048

13049

13050

13051

13053

13054

13057

13058

13064

13065

13066

13067

13068

13069

13070

13071

13072

13073

13074

13075

13076

13077

13078

13079

13080

13081

13082

13083

13086

13087

13088

13094

13095

13096

13098

13102

13103

13104

13108

13111

13113

13114

13115

13116

13123

13124

13125

13129

13130

13135

13136

13142

13143

13144

13145

13146

13147

13155

13156

792


-------
13157

13158

13160

13161

13162

13173

13174

13175

13176

13177

13219

13220

13221

13222

13223

13224

13225

13231

13232

13233

13245

13246

13247

13248

13249

13254

13260

13261

13262

13263

13274

13275

13277

13278

13279

13280

13281

13282

13283

13284

13285

13286

13287

13288

13289

13290

13291

13292

13293

13294

13295

13296

13297

13298

13316

13318

13319

13320

13321

13323

13324

13327

13328

13329

13330

13333

13334

13335

13338

13339

13340

13341

13342

13343

13344

13345

13346

13358

13363

13364

13380

13381

13403

13405

13409

13410

13422

13423

13424

13425

13426

13436

13437

13438

13439

13440

13441

13467

13470

13471

13473

13474

13476

13481

13482

13484

13485

13486

13487

13488

13489

13490

13491

13499

13500

13501

13502

13503

13504

13505

13506

13507

13516

13535

13542

13543

13565

13567

13571

13574

13577

13581

13582

13583

13584

13585

13586

13587

13588

13602

13607

13608

13610

13616

13618

13625

13626

13628

13633

13634

13637

13638

13641

13642

13643

13689

13795

14018

14021

14024

14026

14030

14031

14032

14048

14049

14062

14078

14083

14084

14089

14090

14103

14104

14111

14120

14125

14131

14143

14147

14151

14155

14158

14159

14161

14162

14163

14167

14169

14172

14184

14188

14189

14196

14197

14198

14199

14200

14203

14204

14226

14390

14391

14392

14393

14404

14405

14762

14795

15008

15015

15024

15051

15081

15180

15210

15274

15282

15332

15338

15536

15556

15894

16001

16029

16128

16129

16131

16132

16133

16134

16135

16136

16147

16148

16150

16151

16153

16155

16156

16157

16158

16210

16211

16216

16235

16283

16298

16299

16303

16322

16345

16514

16520

16521

16523

16524

16590

17072

17074

17083

17084

17085

17087

17088

17141

18553

18562

18570

18572

18700

19523

19524

19528

19532

19534

19543

19546

19557

19563

19570

19571

19572

19613

19636

19637

19638

19639

19640

19641

19642

19663

19664

19665

19672

19673

19674

19675





Total:

5,014

Table 9A-20. Union of Concerned Scientists

3121

3122

3123

3124

3125

3126

3127

3128

3129

3130

3131

3132

3133

3134

3135

3136

3137

3161

3162

3163

3164

3165

3166

3167

3168

3169

3170

3171

3172

3173

3174

3175

3176

3177

3178

3179

3180

3181

3182

3184

3185

3186

3199

3202

3203

3208

3213

3215

3217

3220

3222

3225

3226

3227

3228

3229

3230

3231

3232

3233

3234

3235

3236

3237

3238

3239

3240

3241

3242

3243

3244

3245

3271

3272

3273

3274

3310

3311

3312

3313

3314

3332

3333

3337

3338

3339

3340

3341

3349

3350

3353

3356

3359

3360

3362

3365

3370

3382

3386

3388

3391

3424

3425

3426

3427

3428

3429

3430

3431

3432

3433

3434

3435

3452

3453

3462

3463

3464

3465

3466

3467

3468

3469

3470

3471

3472

3473

3474

3476

3477

3478

3488

3489

3490

3491

3492

3493

3508

3509

3511

3514

3520

3521

3522

3523

3524

3525

3524

3527

3528

3529

3530

3531

3532

3533

3534

3535

3536

3537

3538

3539

3540

3541

3542

3543

3544

3545

3546

793


-------
3547

3548

3559

3560

3561

3562

3563

3564

3565

3566

3568

3588

3750

3751

3772

3797

3798

3799

3802

3845

3846

3859

3865

3866

3887

3888

3889

3891

3897

3903

3904

3909

3910

3913

3915

3919

3920

3926

3927

3933

3934

3935

3936

3937

3948

4053

4057

4058

4059

4060

4063

4065

4067

4071

4150

4342

4343

4673

4677

4685

4686

4687

4705

4930

4972

4973

4984

4985

4986

4994

4995

5016

5086

5087

5105

5106

5107

5108

5125

5143

5144

5145

5162

5196

5215

5248

5814

5815

5820

5838

5839

5840

5848

5858

5859

5860

5861

6008

6054

7987

9174

9175

9176

9177

9178

9179

9180

9181

9182

9183

9184

9185

9186

9187

9188

9189

9190

9191

9192

9193

9194

9195

9196

9197

9198

9199

9200

9201

9202

9203

9204

9205

9206

9207

9208

9209

9210

9211

9212

9213

9214

9215

9216

9217

9221

9222

9223

9224

9225

9226

9227

9228

9229

9230

9231

9232

9233

9234

9235

9236

9237

9238

9239

9240

9241

9242

9243

9244

9245

9246

9247

9248

9249

9250

9251

9252

9253

9254

9255

9256

9257

9258

9259

9260

9261

9262

9263

9264

9265

9266

9267

9277

9278

9279

9280

9281

9282

9283

9284

9285

9298

9299

9300

9301

9302

9303

9304

9305

9306

9307

9308

9309

9310

9311

9312

9313

9314

9315

9316

9317

9318

9319

9320

9321

9322

9323

9324

9326

9327

9328

9329

9330

9331

9332

9333

9334

9335

9336

9337

9338

9339

9340

9341

9342

9343

9344

9346

9430

9431

9432

9433

9434

9435

9436

9437

9438

9439

9440

9441

9442

9443

9444

9445

9446

9447

9449

9450

9451

9452

9453

9454

9455

9456

9457

9458

9459

9495

9496

9498

9500

9501

9502

9503

9504

9506

9511

9513

9515

9516

9517

9615

9665

9700

9715

9732

9744

9749

9754

9755

9756

9757

9758

9759

9760

9761

9762

9763

9764

9805

9806

9808

9809

9810

9811

9812

9813

9814

9815

9816

9817

9818

9819

9820

9821

9822

9823

9824

9825

9826

9827

9828

9829

9830

9831

9832

9833

9834

9835

9836

9837

9838

9839

9840

9841

9842

9843

9844

9845

9846

9847

9848

9849

9854

9855

9862

9863

9864

9866

9867

9868

9869

9870

9871

9872

9873

9874

9875

9876

9877

9878

9879

9880

9881

9882

9883

9884

9885

9886

9887

9888

9889

9890

9891

9892

9893

9894

9895

9896

9897

9898

9899

9900

9901

9902

9903

9904

9907

9909

9919

9920

9921

9931

9932

9933

9934

9939

9940

9941

9942

9943

9944

9946

9947

9951

9953

9958

9959

9962

10099

10100

10104

10106

10109

10106

10114

10115

10116

10117

10118

10119

10120

10121

10122

10125

10126

10128

10182

10610

11703

11728

12072

12816

16502

19521

19556























Total:

644

Three thousand and fifty (3,050) letters were received in support of the proposed rule that were not
matched to any mass mail efforts.

794


-------
Table 9A-21. General Support Letters

3374

3385

3393

3740

4031

4048

4139

4294

4341

4432

4483

4487

4488

4522

4721

4751

4797

4921

5559

6138

7497

7498

7584

7585

7653

7654

7655

7661

7975

8684

9118

9541

9549

9569

9717

9743

10166

10169

10170

10521

10522

10637

10660

10729

10732

10734

10757

10762

10902

10906

11096

11104

11105

11106

11373

11374

11382

11393

11396

11401

11426

11477

11528

11529

11530

11531

11534

11535

11596

11597

11598

11599

11600

11601

11602

11603

11605

11606

11607

11608

11609

11610

11611

11612

11613

11614

11615

11616

11617

11618

11619

11620

11622

11623

11624

11626

11627

11628

11630

11633

11634

11635

11636

11644

11645

11647

11648

11653

11654

11655

11656

11667

11669

11670

11671

11672

11673

11674

11675

11676

11677

11678

11679

11680

11681

11682

11683

11684

11685

11686

11687

11688

11689

11690

11691

11692

11693

11694

11695

11706

11707

11708

11710

11767

11768

11769

11770

11769

11782

11783

11792

11801

11802

11803

11804

11805

11806

11807

11808

11809

11844

11846

11847

11848

11849

11850

11851

11852

11853

11854

11855

11856

11857

11862

11863

11868

11869

11870

11871

11872

11873

11874

11876

11879

11881

11883

11893

11896

11897

11898

11899

11900

11906

11907

11908

11909

11910

11911

11912

11913

11918

11919

11920

11921

11922

11923

11930

11931

11932

11940

11941

11942

11943

11944

11945

11946

11947

11948

11949

11951

11952

11953

11954

11955

11969

11970

11971

11972

11973

11974

11975

11976

11977

11978

11979

11980

11981

11982

11983

11984

11985

11986

11987

11988

11989

11990

11991

11992

11993

11994

12003

12007

12008

12009

12011

12012

12013

12014

12022

12024

12025

12026

12027

12028

12029

12030

12031

12032

12033

12035

12036

12037

12038

12039

12040

12041

12042

12043

12045

12046

12047

12048

12051

12053

12054

12059

12060

12061

12062

12067

12073

12083

12084

12085

12086

12087

12091

12095

12099

12104

12128

12131

12133

12148

12155

12156

12221

12222

12223

12224

12226

12227

12228

12230

12231

12232

12238

12252

12253

12254

12255

12256

12257

12258

12259

12260

12261

12262

12264

12265

12278

12281

12283

12288

12290

12295

12296

12297

12307

12312

12314

12316

12334

12335

12336

12339

12345

12369

12374

12375

12376

12377

12378

12379

12381

12382

12383

12402

12405

12459

12460

12461

12503

12504

12505

12506

12509

12510

12511

12513

12518

12520

12525

12526

12532

12533

12534

12535

12536

12546

12547

12548

12560

12561

12562

12563

12564

12565

12566

12567

12568

12569

12570

12571

12572

12617

12618

12619

12620

12621

12622

12626

12627

12628

12629

12648

12649

12651

12652

12653

12661

12662

12663

12664

12665

12673

12682

12683

12684

12685

12686

12687

12704

12705

12706

12707

12709

12710

12711

12722

12723

12724

12725

12755

12756

12757

12758

12759

12760

12761

12762

12763

12764

12765

12766

12767

12780

12793

12794

12795

12796

12797

12799

12800

12807

12814

12881

12886

12887

12888

12896

12948

12949

12950

12951

12952

12953

12954

12955

12956

12957

12958

12959

12960

12961

12962

12963

12964

12965

12966

12967

12968

12969

12970

12971

12976

12977

12987

12988

12989

12992

12994

12995

13005

13006

13007

13008

13010

13110

13112

13117

13118

13119

13120

795


-------
13121

13122

13126

13127

13128

13131

13132

13133

13134

13137

13138

13139

13140

13141

13151

13152

13153

13154

13159

13163

13164

13165

13166

13167

13168

13169

13170

13171

13172

13179

13180

13181

13182

13183

13184

13185

13186

13187

13188

13189

13195

13196

13197

13198

13199

13200

13201

13202

13203

13204

13205

13206

13207

13208

13209

13210

13211

13212

13213

13214

13215

13216

13217

13218

13226

13227

13228

13229

13230

13234

13235

13236

13237

13238

13239

13240

13241

13242

13243

13244

13250

13251

13252

13253

13257

13258

13259

13258

13268

13269

13270

13271

13276

13302

13303

13304

13305

13306

13307

13308

13309

13310

13311

13312

13313

13314

13325

13398

13399

13402

13419

13420

13432

13433

13434

13448

13449

13450

13451

13452

13453

13454

13455

13456

13457

13460

13461

13462

13463

13466

13469

13472

13478

13479

13480

13495

13498

13512

13513

13514

13515

13518

13519

13520

13521

13522

13523

13524

13525

13527

13528

13530

13531

13532

13533

13534

13544

13545

13546

13548

13549

13550

13551

13552

13553

13554

13556

13557

13558

13559

13560

13561

13562

13589

13590

13591

13592

13593

13594

13595

13596

13597

13598

13599

13619

13620

13645

13646

13647

13648

13649

13650

13651

13652

13653

13654

13655

13656

13657

13658

13659

13660

13661

13663

13664

13665

13666

13667

13668

13669

13670

13671

13675

13676

13677

13678

13679

13680

13681

13682

13683

13684

13685

13686

13687

13688

13702

13703

13704

13705

13706

13708

13711

13713

13714

13715

13717

13718

13719

13720

13721

13722

13723

13724

13725

13726

13727

13728

13729

13730

13731

13732

13734

13735

13736

13737

13738

13739

13740

13741

13742

13743

13744

13745

13746

13747

13748

13750

13751

13752

13753

13754

13755

13756

13757

13758

13759

13760

13761

13762

13763

13764

13765

13766

13776

13785

13793

13794

13802

13804

13805

13806

13807

13808

13809

13817

13818

13819

13820

13821

13822

13823

13824

13825

13826

13828

13829

13830

13831

13832

13833

13834

13835

13836

13837

13838

13839

13840

13841

13842

13843

13844

13845

13846

13847

13848

13849

13850

13851

13852

13853

13854

13855

13856

13857

13858

13859

13860

13872

13907

13908

13919

13932

13965

13966

13967

13968

13969

13970

13971

13972

13973

13974

13975

13976

13977

13978

13979

13980

13981

13982

14004

14005

14006

14007

14008

14009

14010

14011

14012

14013

14014

14015

14020

14044

14045

14050

14065

14066

14072

14073

14075

14076

14085

14086

14087

14091

14092

14093

14094

14095

14096

14100

14101

14102

14109

14110

14116

14117

14118

14119

14126

14127

14128

14129

14130

14133

14134

14138

14141

14142

14145

14146

14148

14152

14164

14165

14166

14168

14178

14179

14192

14193

14194

14195

14201

14205

14255

14256

14257

14280

14281

14282

14283

14284

14286

14287

14299

14300

14369

14370

14371

14372

14373

14374

14375

14413

14414

14417

14418

14419

14420

14428

14431

14432

14433

14434

14441

14442

14443

14444

14445

14446

14447

14448

14450

14478

14480

14482

14483

14484

14485

14488

14489

14490

14491

14492

14493

14494

14495

14496

14497

14498

14499

14500

14503

14504

14512

14513

14514

14541

14542

14543

14544

14545

14546

14547

14548

14549

14550

14551

14552

14553

14554

14555

14556

14557

14558

14559

14560

14561

14562

14563

14564

14565

14566

14567

14568

14569

14570

14571

14572

14573

14574

14575

14576

14577

14578

796


-------
14579

14580

14581

14580

14583

14584

14585

14586

14587

14588

14589

14590

14591

14592

14593

14594

14595

14596

14597

14598

14599

14629

14672

14673

14674

14675

14697

14698

14699

14700

14701

14702

14703

14704

14705

14706

14707

14708

14709

14710

14711

14712

14713

14714

14715

14716

14717

14718

14719

14720

14722

14723

14724

14728

14729

14730

14731

14732

14733

14734

14735

14736

14737

14738

14739

14740

14741

14742

14743

14744

14745

14746

14747

14748

14749

14750

14751

14752

14753

14754

14755

14756

14757

14758

14759

14760

14761

14769

14770

14771

14772

14773

14774

14775

14780

14781

14782

14783

14784

14785

14786

14787

14788

14789

14790

14802

14803

14807

14808

14809

14813

14814

14815

14816

14817

14819

14820

14821

14822

14823

14824

14825

14826

14827

14828

14829

14830

14831

14832

14845

14855

14856

14857

14858

14859

14860

14861

14862

14863

14864

14865

14866

14867

14868

14869

14870

14871

14872

14873

14874

14875

14876

14877

14878

14879

14880

14881

14882

14883

14884

14885

14886

14887

14888

14889

14890

14891

14892

14893

14894

14895

14896

14897

14898

14899

14900

14905

14906

14907

14908

14909

14910

14911

14912

14913

14914

14915

14916

14917

14918

14919

14920

14921

14922

14923

14924

14925

14926

14927

14928

14929

14930

14931

14932

14933

14934

14935

14936

14937

14938

14939

14940

14941

14942

14943

14944

14945

14946

14947

14948

14949

14954

14955

14956

14957

14958

14959

14960

14961

14967

14968

14971

14976

14977

14978

14979

14980

14981

14982

14983

14984

14985

14986

14987

14988

14989

14990

14991

14992

14993

14994

14995

14996

14997

14998

14999

15000

15001

15004

15005

15010

15012

15013

15014

15025

15026

15027

15028

15029

15030

15031

15032

15033

15034

15035

15036

15037

15038

15039

15040

15041

15047

15055

15062

15063

15064

15065

15066

15067

15068

15069

15070

15071

15072

15073

15074

15075

15076

15077

15078

15079

15083

15084

15085

15086

15087

15088

15089

15090

15091

15092

15093

15094

15095

15096

15097

15098

15099

15100

15101

15102

15103

15105

15106

15107

15108

15109

15110

15111

15112

15113

15114

15115

15116

15117

15118

15119

15120

15121

15122

15123

15124

15125

15126

15127

15128

15129

15130

15131

15132

15133

15134

15135

15136

15137

15138

15139

15140

15141

15142

15143

15144

15145

15146

15147

15148

15149

15150

15151

15152

15153

15154

15155

15156

15157

15158

15159

15162

15163

15169

15175

15177

15178

15179

15181

15183

15184

15185

15186

15187

15188

15189

15191

15192

15193

15199

15200

15201

15202

15203

15204

15205

15206

15207

15208

15213

15215

15216

15218

15222

15223

15226

15228

15231

15232

15233

15234

15235

15236

15237

15238

15239

15240

15241

15242

15243

15245

15246

15247

15248

15254

15255

15256

15257

15258

15259

15260

15261

15262

15263

15266

15269

15270

15271

15272

15276

15284

15276

15288

15300

15301

15302

15303

15304

15305

15306

15307

15308

15309

15310

15311

15312

15313

15314

15315

15316

15317

15318

15319

15328

15329

15330

15331

15336

15352

15353

15354

15355

15356

15357

15358

15359

15360

15361

15362

15363

15364

15365

15366

15367

15368

15369

15370

15371

15372

15373

15374

15375

15376

15377

15378

15379

15380

15381

15382

15383

15384

15385

15392

15393

15394

15395

15396

15397

15398

15404

15410

15411

15412

15413

15414

15415

15416

15417

15418

15424

15426

15427

797


-------
15428

15429

15430

15431

15432

15447

15451

15452

15453

15454

15455

15456

15459

15462

15463

15464

15466

15467

15468

15469

15470

15471

15472

15473

15474

15475

15476

15477

15478

15479

15480

15481

15482

15493

15497

15499

15500

15501

15502

15503

15504

15505

15506

15507

15508

15509

15510

15511

15512

15513

15521

15524

15535

15537

15538

15539

15540

15541

15542

15543

15544

15545

15546

15547

15554

15555

15561

15562

15563

15564

15565

15571

15572

15573

15574

15575

15576

15577

15578

15579

15580

15581

15582

15583

15584

15585

15586

15587

15588

15589

15591

15592

15593

15594

15595

15596

15597

15598

15599

15600

15601

15602

15603

15604

15605

15606

15607

15608

15609

15610

15611

15612

15613

15614

15615

15616

15617

15618

15619

15620

15621

15622

15623

15624

15625

15626

15627

15628

15629

15630

15631

15632

15633

15634

15635

15637

15638

15639

15640

15641

15642

15643

15644

15645

15646

15647

15648

15649

15650

15651

15652

15653

15654

15655

15656

15657

15658

15659

15660

15665

15666

15667

15679

15692

15693

15694

15695

15696

15697

15698

15699

15700

15701

15702

15703

15704

15705

15706

15707

15708

15709

15710

15711

15712

15713

15714

15715

15716

15717

15718

15719

15720

15721

15722

15723

15724

15725

15726

15727

15728

15729

15730

15731

15732

15733

15734

15735

15736

15737

15738

15739

15740

15741

15742

15743

15744

15745

15746

15747

15748

15749

15750

15751

15752

15753

15754

15755

15756

15757

15758

15759

15760

15761

15762

15763

15764

15765

15766

15767

15800

15801

15804

15805

15806

15807

15808

15809

15810

15811

15814

15815

15816

15817

15818

15819

15820

15821

15822

15830

15832

15833

15834

15835

15836

15837

15838

15839

15840

15841

15842

15843

15844

15845

15846

15847

15848

15849

15853

15854

15855

15856

15857

15858

15859

15860

15861

15862

15863

15864

15874

15877

15878

15879

15881

15885

15886

15887

15888

15889

15890

15897

15898

15899

15900

15901

15902

15903

15904

15905

15906

15907

15908

15909

15916

15927

15928

15929

15936

15937

15938

15939

15940

15941

15942

15943

15944

15945

15946

15947

15957

15962

15963

15964

15965

15966

15967

15968

15969

15970

15971

15972

15973

15974

15975

15976

15977

15978

15979

15980

15981

15982

15983

15986

15987

15988

15989

15990

15991

15992

15993

15994

15995

15996

15995

15998

16002

16003

16004

16015

16016

16017

16018

16019

16020

16021

16022

16023

16033

16034

16035

16036

16037

16038

16039

16040

16041

16042

16043

16044

16045

16048

16050

16051

16056

16057

16058

16059

16061

16062

16063

16070

16071

16074

16076

16077

16078

16079

16082

16085

16086

16087

16088

16089

16090

16091

16093

16103

16105

16106

16107

16108

16109

16110

16111

16112

16113

16118

16119

16120

16123

16124

16137

16138

16139

16140

16141

16142

16143

16144

16145

16146

16149

16152

16163

16167

16168

16169

16170

16171

16172

16173

16174

16175

16176

16178

16179

16180

16181

16182

16183

16184

16185

16186

16187

16188

16189

16191

16193

16194

16195

16196

16197

16198

16199

16200

16201

16202

16203

16204

16205

16206

16219

16232

16240

16243

16244

16245

16246

16247

16248

16249

16250

16251

16252

16253

16254

16255

16256

16257

16258

16259

16260

16261

16262

16263

16264

16265

16266

16267

16268

16269

16270

16271

16272

16273

16274

16275

16276

16277

16278

16279

16280

16284

16288

16289

16290

16291

16292

798


-------
16293

16294

16295

16296

16301

16302

16305

16307

16308

16309

16310

16313

16317

16318

16321

16325

16326

16327

16328

16329

16330

16331

16332

16333

16334

16335

16336

16337

16338

16339

16340

16341

16342

16343

16344

16347

16348

16356

16359

16360

16361

16362

16363

16364

16365

16366

16367

16368

16369

16370

16371

16372

16373

16374

16375

16385

16407

16408

16409

16410

16411

16419

16420

16421

16422

16423

16424

16425

16426

16427

16428

16429

16430

16431

16432

16433

16434

16437

16487

16490

16491

16492

16493

16494

16495

16496

16497

16498

16499

16503

16519

16544

16563

16570

16571

16572

16573

16574

16579

16580

16582

16583

16593

16594

16595

16596

16599

16600

16601

16604

16605

16606

16607

16608

16609

16610

16611

16612

16613

16614

16615

16616

16617

16618

16619

16620

16621

16622

16623

16624

16625

16631

15745

15746

15747

15748

15749

15750

15751

15752

15753

15754

15755

15756

15757

15758

15759

15760

15761

15762

15763

15764

15765

15766

15767

15800

15801

15804

15805

15806

15807

15808

15809

15810

15811

15814

15815

15816

15817

15818

15819

15820

15821

15822

15830

15832

15833

15834

15835

15836

15837

15838

15839

15840

15841

15842

15843

15844

15845

15846

15847

15848

15849

15853

15854

15855

15856

15857

15858

15859

15860

15861

15862

15863

15864

15874

15877

15878

15879

15881

15885

15886

15887

15888

15889

15890

15897

15898

15899

15900

15901

15902

15903

15904

15905

15906

15907

15908

15909

15916

15927

15928

15929

15936

15937

15938

15939

15940

15941

15942

15943

15944

15945

15946

15947

15957

15962

15963

15964

15965

15966

15967

15968

15969

15970

15971

15972

15973

15974

15975

15976

15977

15978

15979

15980

15981

15982

15983

15986

15987

15988

15989

15990

15991

15992

15993

15994

15995

15996

15995

15998

16002

16003

16004

16015

16016

16017

16018

16019

16020

16021

16022

16023

16033

16034

16035

16036

16037

16038

16039

16040

16041

16042

16043

16044

16045

16048

16050

16051

16056

16057

16058

16059

16061

16062

16063

16070

16071

16074

16076

16077

16078

16079

16082

16085

16086

16087

16088

16089

16090

16091

16093

16103

16105

16106

16107

16108

16109

16110

16111

16112

16113

16118

16119

16120

16123

16124

16137

16138

16139

16140

16141

16142

16143

16144

16145

16146

16149

16152

16163

16167

16168

16169

16170

16171

16172

16173

16174

16175

16176

16178

16179

16180

16181

16182

16183

16184

16185

16186

16187

16188

16189

16191

16193

16194

16195

16196

16197

16198

16199

16200

16201

16202

16203

16204

16205

16206

16219

16232

16240

16243

16244

16245

16246

16247

16248

16249

16250

16251

16252

16253

16254

16255

16256

16257

16258

16259

16260

16261

16262

16263

16264

16265

16266

16267

16268

16269

16270

16271

16272

16273

16274

16275

16276

16277

16278

16279

16280

16284

16288

16289

16290

16291

16292

16293

16294

16295

16296

16301

16302

16305

16307

16308

16309

16310

16313

16317

16318

16321

16325

16326

16327

16328

16329

16330

16331

16332

16333

16334

16335

16336

16337

16338

16339

16340

16341

16342

16343

16344

16347

16348

16356

16359

16360

16361

16362

16363

16364

16365

16366

16367

16368

16369

16370

16371

16372

16373

16374

16375

16385

16407

16408

16409

16410

16411

16419

16420

16421

16422

16423

16424

16425

16426

16427

16428

16429

16430

16431

16432

16433

16434

16437

16487

16490

16491

16492

16493

16494

799


-------
16495

16496

16497

16498

16499

16503

16519

16544

16563

16570

16571

16572

16573

16574

16579

16580

16582

16583

16593

16594

16595

16596

16599

16600

16601

16604

16605

16606

16607

16608

16609

16610

16611

16612

16613

16614

16615

16616

16617

16618

16619

16620

16621

16622

16623

16624

16625

16631

17172

17173

17175

17176

17177

17178

17179

17180

17181

17182

17183

17185

17186

17187

17188

17189

17190

17192

17195

17196

17198

17199

17200

17201

17202

17203

17204

17205

17206

17207

17208

17209

17210

17211

17212

17213

17214

17215

17216

17217

17218

17219

17220

17221

17222

17223

17224

17225

17226

17227

17228

17237

17238

17241

17242

17243

17244

17246

17247

17248

17249

17250

17251

17255

17267

17268

17271

17273

17274

17275

17276

17277

17282

17289

17290

17292

17293

17303

17304

17309

17310

17317

17318

17319

17320

17321

17323

17336

17337

17338

17339

17340

17341

17342

17343

17344

17345

17346

17347

17348

17349

17350

17351

17352

17353

17355

17356

17357

17358

17359

17360

17361

17362

17363

17364

17366

17367

17368

17369

17371

17372

17373

17375

17376

17377

17378

17379

17380

17382

17384

17387

17388

17389

17390

17391

17393

17395

17396

17397

17398

17399

17407

17457

17463

17465

17466

17470

17466

17473

17489

17490

17496

17624

17641

17652

17688

17759

17764

17780

17793

17828

17832

17888

17896

17905

17906

17907

17932

17933

17934

17935

17951

17952

18040

18041

18042

18044

18045

18046

18047

18048

18049

18065

18249

18260

18267

18286

18287

18288

18302

18306

18313

18319

18361

18362

18363

18364

18365

18366

18367

18368

18369

18370

18401

18406

18413

18503

18504

18505

18506

18507

18511

18547

18548

18551

18552

18554

18557

18616

18646

18668

18669

18670

18671

18672

18695

18696

18697

18708

18712

18719

18743

18828

18850

18869

18878

18879

18918

18928

18929

18957

18972

18973

18974

18987

19004

19009

19010

19013

19016

19024

19027

19028

19030

19039

19084

19089

19090

19095

19097

19098

19099

19102

19103

19117

19118

19119

19124

19144

19149

19154

19155

19156

19159

19161

19162

19164

19165

19166

19167

19172

19173

19175

19177

19179

19195

19196

19198

19202

19206

19220

19221

19223

19224

19226

19227

19228

19229

19236

19238

19239

19240

19241

19242

19244

19246

19247

19248

19249

19255

19256

19257

19258

19259

19260

19262

19264

19265

19271

19273

19274

19275

19276

19277

19278

19279

19280

19281

19282

19283

19284

19285

19286

19287

19290

19293

19294

19300

19301

19308

19309

19328

19330

19331

19332

19433

19507

19518

19519

19529

19531

19554

19561

19575

19576

19577

19582

19590

19591

19594

19596

19597

19598

19599

19600

19602

19604

19605

19607

19614

19616

19618

19619

19621

19623

19624

19626

19655

19656

19657

19658

19676

19695

19696

19697

19698





















Total:

3,050

800


-------
9B - General Opposition

Comment 1: The EPA received 4,830 mass-mail and form letters expressing general opposition to the
electric generating units NESHAP. Commenter's concerns include the rule's effect on electricity prices,
system dependability, employment, and the effect on small businesses and the overall economy. Due to
the high number of comments for this proposed rule, these comments were categorized and sorted
according to the group that organized the mass-mail campaign.

The U.S. Docket office identified 4,527 mass-mail comment letters and assigned them to 6 DCNs,
simplifying this process. These mass-mail DCNs are listed in Table 9B-1 of this section with the count
of comment letters and the associated organization.

More mass-mail comment letters were identified from the remaining comment letters and are listed in
Tables 9B-2 through 9B-4 in this section.

Letters expressing general opposition that are not associated with any mass-mail campaign are listed in
Table 9B-5 in this section.

Many organizations provided members with form letters. Form letters containing substantive comments
had a few representative letters excerpted and summarized for the Response to Comments document.
The remaining letters are listed here.

Many commenters (17295, 17401, 17748, 17749, 17750, 17763, 17778, 17783, 17788, 17792, 17822,
17825, 17826, 17827, 17866, 17890, 17891, 17897, 17910, 17924, 18414, 18482, 18499, 18705, 18706,
18894, 18936, 18937, 18944, 19549, 19559, 19560, 19566) representing municipal utilities expressed
concerns about the proposed rule. These commenters asked that the EPA evaluate the impact of the
proposed rule under SBREFA, UMRA and EO 13563, EO 13132, EO 12866, and EO 13211. Comments
are discussed in further detail by commenter 18038.

Response to Comment 1: The EPA acknowledges the general concerns of the commenters regarding
the Mercury and Air Toxics Standards, and responses to comments elsewhere in this document generally
address those concerns. Comments and responses relating to the consideration of SBREFA, UMRA, EO
13563, EO 13132, EO 12866, andEO 13211 may also be found elsewhere in this document.

801


-------
Section 9B Tables
Mass Mailings - General Opposition to the Proposed Rule

Table 9B-1. Mass mail comments identified by the U.S. Docket Office

DCN

Docket Entry

Count

19651

Mass Comment Campaign sponsoring organization unknown

142

19633

Mass Comment Campaign sponsoring organization unknown

885

19646

Mass Comment Campaign sponsoring organization unknown

20

19645

Mass Comment Campaign sponsoring organization unknown

945

19650

Mass Comment Campaign sponsoring organization unknown

1,788

19652

Mass Comment Campaign sponsoring organization unknown

747

Total:

4,527

In addition to the mass mailings identified by the U.S. Docket Office, 268 mass mail comments were
also identified by RTI International.

Table 9B-2. American Electric Power

14487

14509

14511

14520

14610

14612

14613

14614

14616

14617

14618

14619

14620

14621

14624

14628

14630

14631

14634

14635

14636

14637

14638

14639

14640

14641

14642

14643

14644

14645

14646

14647

14649

14651

14652

14654

14656

14658

14659

14660

14662

14664

14666

14667

14668

14671

14679

14680

14681

14682

14683

14684

14685

14686

14687

14688

14689

14690

14691

14692

14693

14694

15190

15439

15560

15566

15567

15568

15569

15661

15662

15663

15664

15670

15768

15769

15770

15771

15772

15773

15779

15780

15781

15782

15783

15785

15793

15794

15795

15796

15797

15798

15799

15812

15825

15826

15827

15829

15850

15851

15868

15869

15870

15871

15872

15880

15882

15924

15925

15935

15948

15950

15958

16127

16130

16154

16159

16160

16161

16162

16208

16212

16221

16222

16223

16224

16234

16239

16285

16286

16287

16300

16314

16315

16316

16324

16349

16350

16351

16353

16354

16355

16357

16358

16376

16379

16381

16379

16436

16450

16461

16488

16489

16501

16517

16536

16537

16542

16597

16845

17108

17184

17300

17330

17331

17332

17333

17334

17335

17354

17365

17370

17445

17472

17486

17908

17947

17953

18186

18301

18357

18377

18558

18565

18571

18620

18621

18623

18631

18661

18662

18664

18682

18683

18686

18689

18690

18692

18693

18694

18699

18776

18780

18784

18841

18849

18874

18917

18925

18926

18927

18940

18955

18969

18971

19085

19295

19320

19625



















Total: 219

802


-------
Table 9B-3. Chamber of Commerce

17657

17658

17659

17660

17661

17680

17684

17685

17686

17693

17694

17695

17700

17708

17717

17779

17823

18415

18416

18417

18418

18420

19296



Total:

23

Table 9B-4. Public Service Company of Oklahoma

18959

18960

18975

19025

19026

19029

19091

19096

19100

19109

19140

19141

19142

19148

19153

19158

19160

19163

19168

19174

19176

19261

19266

19461

19527

19584





















Total:

26

The EPA received 35 letters opposing the proposed rule that were not matched to any mass mail efforts.

Table 9B-5. General Opposition Letters

12152

12192

12708

13749

14003

14427

14501

14519

14625

14818

15104

16412

16414

16415

16416

16417

16438

16543

16718

16947

16966

17032

17233

17269

17280

17329

18279

18615

18622

18867

18966

19178

19302

19562

19635



Total:

35

803


-------
CHAPTER 10: INCORPORATION BY REFERENCE

10 - Incorporation by Reference

Comment: Many commenters requested that the remarks of other commenters be incorporated into their
own comments on the proposed rule. The table below lists the commenters who have been referenced,
followed by the commenters who asked to incorporate the referenced commenters' remarks.

Specifically, the first column in Table 10-1 is a list of commenters who were referred to by other
commenters. The second column gives a short name for the commenters who were referenced. The third
column provides a list of the commenters who referred to each of the referenced commenters.

Response: The EPA acknowledges the general concerns of the commenters regarding the proposed
Mercury and Air Toxics Standards and has responded to them in this document, the preamble to the final
rule, and other associated technical and regulatory impact analysis supporting materials.

Table 10-1. Incorporation by Reference

Referenced

Referenced



Commenter

Commenter

Referencing Commenters

DCN

Short Name



17799

ACCCE

17790

17877

AECI

19094

17815

AECT

17904, 18785

19114

AEP

17715, 17757, 18907, 19041

17810

ANGA

17853

8443, 17868

APPA

17655, 17702, 17705, 17767, 18015, 18018, 18031, 18032,
18437, 18500, 18831, 19121, 19213

17754

ARIPPA

18427

17757

Buckeye

19041

17760

Class 85

17702, 17722, 17776, 17807, 17870a, 17902, 17909, 17920,
18018, 18020, 18831

17808

Clean Energy
Group

17870a, 18025

18500

CPG

18437

17758

EEI

17627, 17770, 17772, 17776, 17790, 17800, 17805b, 17807,
17820, 17870a, 17881, 17902, 17920, 18015, 18031, 18428

18037

EPGA

17627

17621

EPRI

17627, 17705, 17722, 17730, 17757, 17790, 17800, 17820,
17821, 17881, 17886, 17902, 17904, 18015, 18020, 18021,
18428, 18437, 18443, 19041

17638

FCG

17702, 17769, 17807, 17814, 18018, 18831

18018

FMEA

18831

17930

GCLC

17813, 17904, 18785

17698

GPA

17710

19506

IDEM

19212

19122

LADWP

19121

17724

LEC

17722, 17805, 18031

804


-------
17623

LPPC

17705, 18437, 18831

18426

MDEQ

17881

19742

MMA

17881

18488

MOG

17627, 17800

17297

MPSC

17881

17640,

NAM

18031

19580



17701,

NARUC

16850

17791



17842

NDPSC

17805

17735

New Units

17817

18033

NMA

17901, 17904, 18051, 18424, 18489

17689

NRECA

17197, 17909, 17730, 17757, 17813, 17817, 17909c, 18020,
18429, 18443, 18820, 19041, 19094

17736

OEUG

17627, 17715, 17772

16549

PACE

17137, 17782

18448,

PJM

17804

18441



16873

PUCO

17856

18538

TX PUC

18034

17775

UARG

17197, 17627, 17705, 17715, 17728, 17730, 17737, 17770,
17772, 17790, 17795, 17800, 17820, 17821, 17868d, 17881,
17886, 17904, 18015, 18021, 18031, 18033, 18428, 18429,
19041, 19121, 18203

16496

UJAE

17817

17656

WBRT

17805

19741

West

17705, 17737, 18015

14115

Willie Soon

14368

a NextEra Energy Inc. (DCN 17870) incorporated by reference comments from several contributors, but
with the caveat, "except in instances when the comments of these industry groups may conflict with
NextEra Energy's position as set forth in the comments below."

b Montana-Dakota Utilities Company (DCN 17805) incorporated by reference the majority of EEI's
comments, as identified in Montana-Dakota Utilities Company's letter.

c PowerSouth Energy Cooperative (DCN 17909) incorporated by reference comments from NRECA on
setting numerical standards.

d American Public Power Association (DCN 17868) incorporated by reference UARG's comments in
regard to data availability, data analysis, conversion errors, and MACT monitoring.

805


-------
APPENDIX A: PUBLIC HEARING PARTICIPANTS

List of Speakers for Public Hearing - Atlanta - 26 May 2011

Time

Name

Affiliation

9:15

Josh Galperin

Southern Alliance for Clean Energy

9:20

Jen Rennicks

Southern Alliance for Clean Energy

9:25

Katie Preston

Georgia Interfaith Power and Light

9:30

Colleen Kiernan

Georgia Sierra Club

9:35

Peter Bahouth

US Climate Action Network

9:40

H. James Gooden

American Lung Association Board of Directors

9:45

Robert Kappelmann

Energy and Environmental Policy Consultants

9:50

Dr. Anne Mellinger-
Birdsong

Georgia Chapter of the American Academy of Pediatrics
Committee on Environmental Health

9:55

Janice Nolen

American Lung Association

10:00

Charles "Clay" B. Jones,
III

Georgia Traditional Manufacturers Association

10:05

William P. Brown

Individual

10:10

Representative Scott
Hoi comb

GA State Representative

10:15

Dale Kemmerick

POPE

10:20

Stanley P. Saunders

Individual

10:25

Juliet Cohen

Upper Chattahoochee River Keeper

10:30

Rebecca Watts-Hull

Mothers & Others for Clean Air

10:35

Joe Hudson

Farmers & Merchants Bank

10:40

Chris Hob son

Southern Company Services

10:45

Rev. Woody Bartlett

Georgia Interfaith Power & Light

10:50

Robert D. Bullard

Environmental Justice Resource Center
Clark Atlanta University

10:55

Dr. Yolanda Whyte

Individual

11:00

Mike Kennedy

Progress Energy

11:05

Byron T. Burrows

Tampa Electric Company

11:10

Alison Amyx

Georgia Interfaith Power & Light

11:15

Bob Donaghue

Georgia Interfaith Power & Light

11:20

Clark Efaw

Georgia Interfaith Power and Light

11:25

Dr. James Rust



11:30

Thomas Pearce

Sierra Club

11:35

Robin Mann

Sierra Club

11:40

Jaffer Khimani

Clean Air Task Force

11:45

Mark MacLeod

Environmental Defense Fund

11:50

John B. Hammond

National Wildlife Federation

11:55

Jack Thirolf

Business Council for Sustainable Energy

12:00

Dabney Dixon

Individual

12:05

Lance Brown

Partnership for Affordable Clean Energy (PACE)

12:10

Steve Earle

UMWA Region 3

12:15

Virginia Galloway

Americans for Prosperity

12:20

Kevin McGrath

GA Trout Unlimited

12:25

Alan O. Toney

Individual

806


-------
Time

Name

Affiliation

12:30

James Capp

Georgia Air Protection Branch

12:35

Joy Kramer

GA Solar Energy Association

12:40

Thelma Heywood

Sierra Club

12:45

Roger Mills

Individual

12:50

Sean Hutchins

KY Environmental Foundation

2:10

Seandra Rawls

Southern Alliance for Clean Energy

2:15

Eriqua Foreman Williams

Southern Alliance for Clean Energy

2:20

Emily Enderlee

Earthjustice

2:25

Danny Schweinhart

Individual

2:30

Alexei Laushkin

The Evangelical Environment Network

2:35

Rev. Richard Cizik

Evangelicals for the Common Good

2:40

Glen Hooks

Sierra Club

2:45

Katherine Helms
Cummings

FACE

2:50

Midge Sweet

Georgians for Smart Energy Coalition

2:55

Lynn Redwood

SAFE MINDS

2:25

Jennette Gayer

Environment Georgia

2:55

Dave Muhly

Sierra Club

3:00

Eddie Ehlert

Individual

3:05

Lyndsay Moseley

Sierra Club

3:10

Imran Battla

The Prana Group

3:15

David Richardson



3:20

Ron Shipman

Georgia Power Company

3:25

Seth Hutchins

KY Environmental Foundation

3:30

Thomas Hutegger

Individual

3:35

John Walsh

Sierra Club

3:40

Robert Fletcher



3:45

Elizabeth Crowe

Kentucky Environmental Foundation

3:50

Kathy Little

Kentucky Environmental Foundation

3:55

Robert Ukeiley

Citizen

4:00

Natalie Crone & Student
group

Chelsea Carroll
Matt Callo
Shawn Hutchins
Alex English
Austin Delph
Seth Hutchins

Kentucky Environmental Foundation

4:05

Simon Montelongo

Kentucky Environmental Foundation

4:10

Benita Dodd



4:15

Shelia Tyson

Citizen-Birmingham, A1

4:20

Jessica Spruill

Southern Energy Network

4:25

Joan Lindop

Sierra Club GA

4:30

Elizabeth Lopez

Global Warming and Energy Team

807


-------
Time

Name

Affiliation

4:35

Patti Gettinger

Individual

4:40

Rel Corbin



4:45

Cassy Hobert

Kentucky Environmental Foundation

4:50

Michael J. Churchman

Alabama Environmental

4:55

Molly Embree

Environment Georgia

5:00

April Ingle

GA River Network

5:05

Natasha Herbert



5:10

Arthur Gibert

Sierra Club

5:15

Andrea Lyle

Individual

5:20

John Krueger

Georgia Chamber of Commerce
30303

5:25

Flora Tommie

Sierra Club / Perkerson Civic Association (PCA)

5:30

June Deen

American Lung Association in Georgia

6:40

Lev Guter

Sierra Club

6:45

Jenna Garland

Southern Energy Network

6:50

Michael Wall

Environment Georgia

6:55

Bill Cunningham

Unions for Jobs and the Environment (UJAE)



Mark Woodall

Sierra Club Georgia Chapter

7:10

Tony C. Anderson

The Lets Raise a Million Education Fund

7:15

Erin Glynn (presented
video testimony narrated
by Erin Savage)

Sierra Club

7:20

John Noel

Individual

7:25

Burt Lesnick

American Thoracic Society

7:35

Brandon Sutton

Sierra Club

7:40

Carly Queen

Individual

7:45

Melissa Nummink

Individual

808


-------
List of Speakers for Public Hearing - Chicago - 24 May 2011

Time

Name

Affiliation

9:15

Rev. Dr. Clare
Butterfield

Faith in Place and the Illinois Interfaith Power and Light
Campaign

9:20

Rev. Faith Bugel

Environmental Law and Policy Center

9:25

Brian Urbaszewski

Respiratory Health Association of Metropolitan Chicago

9:30

Amy M. Trojecki

Exelon Business Services Company

9:35

Ben Lowe

Evangelical Environmental Network

9:40

Verena Owen

Sierra Club

9:45

Peter Iwanowicz

American Lung Association

9:50

Sarah Hodgdon

Sierra Club

9:55

Matthew Dunne for Lisa
Madigan

IL Attorney General

10:00

Mary Gade

Gade Environmental Group, LLC

10:05

Catie Krasner

Environmental Illinois

10:10

Steve Frenkel

Union of Concerned Scientists

10:15

Jerry Mead-Lucero

Pilsen Environmental Rights and Reform Organization

10:20

William "Bill"
Kempiners

American Lung Association Advocacy Committee

10:25

Jennifer Johnson
Monberg

Individual

10:30

Lyman C. Welch

Alliance for the Great Lakes

10:35

Erika Dornfeld

Faith in Place

10:40

Michael T.W. Carey

Ohio Coal Association

10:45

Matt Most

Encana Natural Gas Inc.

10:50

Dr. Michael S. Hogue

Meadville Lombard Theological School

10:55

Matthew Soerens

Individual

11:00

Jerome Stone

Individual

11:05

Cathy S. Woollums

MidAmerican Energy Holdings Company

11:10

Dr. Lin Kaatz Chary

Indiana Toxics Action

11:15

Dr. Dawn M. Nothwehr

Catholic Theological Union

11:20

Dr. Helen J. Binns

American Academy of Pediatrics

11:25

Nancy Bultinck

Respiratory Health Association of Metropolitan Chicago

11:30

Jim Ginderske

Neighbors for a Healthy Rogers Park

11:35

Michael Murray

Individual

11:40

Eve Pytel

Metropolitan Mayors Caucus Clean Air Counts Campaign

11:45

Terry Grace

Educator - Retired

11:50

Cory Jones

Sierra Club

11:55

Don Ferber

Sierra Club

12:00

Rev. Homer Cobb

NAACP

12:05

Kimberly Wasserman

Little Village Environmental Justice Organization /NETAC

12:10

Ian Viteri

Little Village Environmental Justice Organization

12:15

Victoria Persky

Individual

12:20

John Blair

Valley Watch

12:25

Leigh Touchton

NAACP

12:30

Dr. Howard Ehrman

UIC/LVESO

809


-------
Time

Name

Affiliation

12:35

Benjamin Stewart

Lutheran School of Theology at Chicago

12:40

Janet Bohn

Individual

12:45

David Shaw

National Association of Clean Air Agencies

12:50

Brenda Archambo

Individual

2:00

Rose Gomez

Sierra Club

2:05

Chris Pado

Individual

2:10

Dr. Suzanna McColley

American Thoracic Society

2:15

Richard Cogan

President of Textile Industries, Inc.

2:20

Margaret Nelson

League of Conservation Voters

2:25

Shannon Fisk

Natural Resources Defense Council

2:30

Laura Kratz

League of Women Voters of Illinois

2:35

Alfred B.J. Williams II

NAACP

2:40

Brad Vam Guilder

Ecology Center, Ann Arbor, MI

2:45

Susan Michetti

Individual

2:50

Howard A. Learner

Environmental Law and Policy Center

2:55

Boise Jones

Sierra Club/EJAM

3:00

Ade Ob a Abdalla

Energy Efficiency and Environmental Health Services - Task
Force

3:05

Dennis Nelson

NEIS

3:10

Jerry B. Cain

Judson University

3:15

Rebecca Rossof

Climate and Energy Program

3:20

Michelle Martinez

Sierra Club

3:25

Ingrid Wendland
(daughter of Juliee De La
Terre)

Individual

3:27

Juliee De La Terre

Individual

3:30

Lance Green

Individual

3:35

Patricia Rosenthal

Sierra Club

3:40

Kelly Pierce

Individual

3:45

Patricia A.S. Crowley

Kalamazoo County Drain Commissioner

3:50

James McPike

Individual

3:55

Vivian Hood

Individual

4:00

Joan Arnold

Individual

4:05

Dr. Sarah Lovinger

Physicians for Social Responsibility

4:10

Susan E. Harley

Michigan Policy Director

4:15

Lee Sprague

Little River Band of Ottawa Indians
Tribal Council

4:20

Danielle Korpalski

National Wildlife Federation

4:25

Frank Szollosi

National Wildlife

Federation's Great Lake's Office in Ann Arbor

4:30

Suhail Barot

Individual

4:35

Amy Allen

Individual

4:40

Dr. Barbara Timmermans

Evangelical Environmental Network

4:45

Frederick Ellsworth

Sierra Club

4:50

Dr. Daniel N. Weber

Children's Environmental Health Sciences Center

810


-------
Time

Name

Affiliation

4:55

Amanda Kaley

Individual

5:00

Susan Williams

Sierra Club

5:05

David A. Creech

ELCA World Hunger

5:10

Dr. Edward (Ted)
Naureckas

Individual

5:15

Sue Blaine

Labadie Environmental Organization/Individual

5:20

Dana March

Individual

5:25

Jason Duba

Individual

5:30

Jennifer Jansen

National Wildlife Federation

5:35

Jocelyn Travis

NAACP

5:40

David L. DePrez

Individual

5:45

Rose Joshua

NAACP

5:50

Auriel Banister

Little Village Environmental Justice Organization

6:45

Olivia Woollam

University of Chicago Climate Action Network, and the
Chicago Youth Climate Coalition

6:50

Caroline Wooten

UChicago Climate Action Network, Chicago Youth Climate
Coalition

6:55

Pamela Ortner

Individual

7:00

Donna Hriljac

Individual

7:05

Rev. Theresa Dear

NAACP

7:10

Jim Schneider

Individual

7:15

Dr. Sam Dorevitch

University of Illinois

7:20

Susanne Brooks

Environmental Defense Fund

7:25

Brian Perbix

Sierra Club

7:30

Sherry Leonard

Individual

7:35

Marianne Flanagan

Individual

7:40

Jessica Brackett

Individual

7:45

Paul Kim

University of Chicago

7:50

Joyce Blumenshine

Heart of Illinois Sierra Club

7:55

Dr. Maureen McCue

Iowa Physicians for Social Responsibility

8:00

Susan Lannin

Individual

8:05

Tim Sutherlin

Individual

8:10

Kristen Vyhnal

Individual

8:15

Melissa Mullarkey



8:20

Alexandra Sipiora

Individual

8:25

Kevin Carol

Individual

8:30

Adam Burke

Individual

8:35

Marybeth Gardam

Women's International League for Peace & Freedom

8:40

Richard Stucky

Individual

8:45

Grace Pai

University of Chicago

8:50

Dr. Robert A. Rosenstein

Sierra Club, Union of Concerned Scientists, and Green America

8:55

Carol Chaplan

GREENFAITH

9:00

Chris Didato

Individual

9:05

Bonnie Atkins

Clean Air Muscatine

811


-------
List of Speakers for Public Hearing - Philadelphia - 24 May 2011

Time

Name

Affiliation

9:15

Rabbi Daniel Swartz

Scranton Area Ministerium and PA Interfaith Power and Light

9:20

Deborah P. Brown

The American Lung Assoc.

9:25

Charles McPhedran

Citizens for PA's Future (PennFuture)

9:30

Robin Mann

Sierra Club

9:35

Joseph Minott

Clean Air Council

9:40

Adam Garber

Penn Environment

9:45

Paul J. Miller

Northeast States for Coordinated Air Use Management

9:50

Dr. Walter Tsou

Philadelphia Physicians for Social Responsibility

9:55

Stephen Harvey

Sierra Club; Pepper Hamilton LLP

10:00

Reverend Cheryl Pyrch

Summit Presbyterian Church

10:05

Eileen O'Boyle

Greenpeace USA

10:10

Jay Butera

Individual

10:15

Rev. Mitchell Hescox

Evangelical Environmental Network

10:20

Leslie G. Fields

Sierra Club

10:25

Paul G. Billings

American Lung Association

10:30

James W. Banford, Jr.

International Brotherhood of Boilermakers; Boilermakers
Local Lodge No. 13

10:35

Dr. Poune Sabieri

Sierra Club

10:40

Doug Keith

Sierra Club

10:45

Joy Bergey

The Center for the Celebration of Creation

10:50

Kevin M. Stewart

American Lung Association of the Mid-Atlantic

10:55

Christine Guhl

Sierra Club



Statement from Anna
Maria Caldera read by
Christine Guhl

Individual

11:00

Scott Segal

Electric Reliability Coordinating Council/B&G

11:05

Corinne Wright

Sisters of St. Francis of Philadelphia

11:10

Thomas Au

Clean Air Board of Central Pennsylvania

11:05

Ed Perry

National Wildlife Federation

11:10

Don Robertson

Isaac

Walton League of America

11:15

Rev. Horace W. Strand

Chester Environmental Partnership

11:20

William Kramer

Sierra Club

11:25

Dr. Scott Manaker

American Thoracic Society

11:30

Chris Salmi

New Jersey Department of Environmental Protection

11:35

Michael Bradley

The Clean Energy Group

11:40

Anthony Di S orb o

Individual

11:45

John McLaughlin

Individual

11:50

Jack Miller

Individual

11:45

Mariko Franz

Individual

11:50

Paul J Mellon, Jr

Novetas Solutions, LLC

11:55

Jim Black

Partnership for Sustainability in Delaware

12:00

Kevin Pflug

Sierra Club

12:05

Mervyn Kline

Individual

812


-------
Time

Name

Affiliation

12:10

Alicia McDevitt

MA Dept of Environmental Protection

12:15

Margaret Motheral

Union of Concerned Scientists

12:20

Catherine Bowes

National Wildlife Federation

12:25

Rabbi Kevin M. Kleinman

Individual

12:30

Jamin Bogi

Group Against Smog and Pollution

2:15

Nancy Parks

SC/PA Chapter/Clean Air Committee

2:20

Jay Butera

One Million Calls For Clean Energy

2:25

Katie Feeney

Clean Air Council

2:30

Tyra Bryant-Stephens

The Community Asthma Prevention Program

2:35

Candance Cheatham

Individual

2:40

Mark Schmerling

Individual

2:45

Dr. Rima Synnestivedt

Sierra Club

2:50

Robert Cooper

Union of Concerned Scientists

2:55

Sarah Bucic

Delaware City Environmental Coalition

3:00

Dr. Kristen Welker-Hood

Physicians for Social Responsibility

3:05

Gretchen Dahlkemper-
Alfonso

Individual

3:10

Judith Focareta



3:15

Sarah Landini

Pittsburgh City Council

3:20

John El wood

Evangelical Environmental Network

3:25

Rev. Leah Schade

The Evangelical Lutheran Church in America

3:30

Donna Henry

Individual

3:35

Dr. Kevin Osterhoudt

American Academy of Pediatrics

3:40

Theodore Carrington

NAACP

3:45

Gina E. Wood

Joint Center for Political and Economic Studies

3:50

John Hanger

PA Dept of Environmental Protection
Hanger Consulting

3:55

Teresa Mendez-Quigley

Women's Health and Environmental Network

4:00

Amy Roe

Individual

4:05

Geneva Boyer

Individual

4:10

Shreena Bindra

Individual

3:55

Coralie A. Pryde

Individual

4:00

Josh Nelson

CREDO Action from Working Assets

4:20

Jeff A McNelly

ARIPPA

4:25

Brenda Afzal

HCWH, U.S. Climate Policy Coordinator

4:30

Ed Braun

City of Philadelphia Department of Public Health, Air
Management Services

4:35

Mary Anne Rushlau

Sierra Club

4:40

Jenny Kordick

Individual

4:45

Bruce Alexander

Exelon Corporation

4:50

Kate Etherington

Philadelphia Physicians for Social Responsibility

4:55

Alex Milone



5:00

Mandy Warner

Environmental Defense Fund

5:05

Katie Edwards

Individual

5:10

Phillipa Strahm

League of Conservation Voters

5:15

James Grande

Sierra Club

813


-------
Time

Name

Affiliation

5:20

James Kelley

Individual

5:25

Freyda Black

Individual

6:45

A1 Rizzo

American Lung Association

6:50

Matthew Pale

PennEnvironment

6:55

Joe Parrish

American Lung Association of New Jersey

7:00

Kendall Mackey

National Wildlife Federation

7:05

Adam H. Cutler

Public Health and Environmental Justice Law Clinic

7:10

Rachel Mentin

Individual

7:15

Lynn Jaeger

Eastern MontCo Action

7:20

Captain Joel Fogel

Waterwatch International

7:25

Kate Zaidan

Individual

7:30

Myriam Fallon

Greenpeace

7:35

Christina Marie Glessner

Individual

7:40

Rosa Michmya

Individual

7:30

Dr. Gwen DuBois

Chesapeake Physicians for Social Responsibility

7:35

Dr. Cindy Parker

Chesapeake Physicians for Social Responsibility

7:40

Jeff Player

Individual

7:45

Lisa Hastings

Individual

7:50

Stephen Shapiro

Chesapeake Physicians for Social Responsibility

7:55

Hollister Knowlton

National Council of Churches and the Quaker Earthcare
Ministry

8:00

Georgina Shanley

Citizens United for Renewable Energy

8:05

Steven Fenichel

Citizens United for Renewable Energy

8:10

Miranda Outman



8:15

Martin Hage

Individual

8:20

Ann Dixon

Penn Environment

8:25

Jay Fabrikant

Individual

814


-------
12/08/11 DRAFT

APPENDIX B: LIST OF COMMENTERS

DCN

Commenter
Name

Commenter Affiliation

EPA-HQ-OAR-2009-0234-6543-A1

Chris M. Hob son

Southern Company

EPA-HQ-OAR-2009-0234-6584-A1

Sheila C.
Holman

North Carolina Department of
Environment and Natural
Resources (NCDENR), Division
of Air Quality (NC DAQ)

EP A-HQ-0 AR-2009-023 4-663 7-A1

Naomi Goodman

Electric Power Research Institute
(EPRI)

EPA-HQ-OAR-2009-0234-6640-A1

A. Mellinger-
Birdsong

None

EP A-HQ-0 AR-2009-0234-8443-A1

Theresa Pugh

American Public Power
Association (APPA)

EP A-HQ-0 AR-2009-0234-9738-A1

H. Tsourous

None

EP A-HQ-0 AR-2009-0234-10167-A1

Mike Roddy

Seminole Electric Cooperative, Inc

EPA-HQ-OAR-2009-0234-10569-A1

Juan Ramirez

Florida Electric Power
Coordinating Group, Inc. (FCG)

EPA-HQ-OAR-2009-0234-10750-A1

John M.
McManus

American Electric Power (AEP)

EP A-HQ-0 AR-2009-0234-10821-A2

Michael J. Nasi

Jackson Walker, LLP on behalf of
Gulf Coast Lignite Coalition
(GCLC)

EP A-HQ-0 AR-2009-0234-10822-A2

L. Mohorovic,
PhD

None

EPA-HQ-OAR-2009-0234-10942-A1

John D. Free

Alabama Public Service
Commission (APSC)

EP A-HQ-0 AR-2009-0234-10943-A1

James 0. Vick

Gulf Power Company

EPA-HQ-OAR-2009-0234-10944-A1

Charles
McPhedran

Citizens for Pennsylvania's Future
(PennFuture)

EP A-HQ-0 AR-2009-0234-10987-A1

Rae Cronmiller,
James J. Nipper

National Rural Electric
Cooperative Association
(NRECA), American Public
Power Association (APPA)

EP A-HQ-0 AR-2009-0234-11107-A1

Alan H.
Lockwood

None

EP A-HQ-0 AR-2009-0234-11889

Douglas K.
Stevens

None

EP A-HQ-0 AR-2009-0234-12050-A2

Thomas Au

Clean Air Board of Central
Pennsylvania (CAB)

EP A-HQ-0 AR-2009-0234-12267-A1

S. W. Kuntz,
PhD



EP A-HQ-0 AR-2009-0234-123 80-A2

Anonymous
public comment

None

815


-------
12/08/11 DRAFT

EPA-HQ-OAR-2009-0234-12462-A1

Lee Sprague

Little River Band of Ottawa
Indians

EPA-HQ-OAR-2009-0234-12798-A2

Alisa Gravitz

Green America

EPA-HQ-OAR-2009-0234-12991 -A1

Jeffrey Quick

Utah Geological Survey, Utah
Department of Natural Resources

EPA-HQ-OAR-2009-0234-12996-A2

Michael P.
Halpin

Division of Air Resource
Management, Florida Department
of Environmental Protection
(DEP)

EPA-HQ-OAR-2009-0234-13178-A1

Patrick
O'Loughlin

Buckeye Power, Inc.

EPA-HQ-OAR-2009-0234-13 526-A1

Susana M.
Hildebrand

Texas Commision on
Environmental Quality (TCEQ)

EPA-HQ-OAR-2009-0234-13 529-A1

Byron T.
Burrows

Tampa Electric Company (TECO)

EPA-HQ-OAR-2009-0234-13 827-A1

Darrell Dorsey

Kansas City Board of Public
Utilities (BPU)

EPA-HQ-OAR-2009-0234-14017-A1

David R. Tripp
and Dennis Lane

Stinson Morrison Hecker LLP on
behalf of Westar Energy, Inc.

EPA-HQ-OAR-2009-0234-14069-A1

Raymond L.
Evans

FirstEnergy Corp.

EPA-HQ-OAR-2009-0234-14070-A1

G. Vinson
Hellwig

Michigan Department of
Environmental Quality (MDEQ)

EPA-HQ-OAR-2009-0234-14070-A2

G. Vinson
Hellwig

Michigan Department of
Environmental Quality (MDEQ)

EPA-HQ-OAR-2009-0234-14115- A 1

Dr. W. Soon

None

EPA-HQ-OAR-2009-0234-143 68-A1

Niger Innis

Congress of Racial Equality on
behalf of Affordable Power
Alliance (APA)

EPA-HQ-OAR-2009-0234- 15002-A1

Barbara Gottlieb

Physicians for Social
Responsibility (PSR)

EPA-HQ-OAR-2009-0234-15160-A1

Dr. Lawrence
Raymond

Clean Air Carolina

EPA-HQ-OAR-2009-0234-15182-A2

James Zorn

Great Lakes Indian Fish and
Wildlife Commission (GLIFWC)

EPA-HQ-OAR-2009-0234- 15678-A2

William Skrabak

Transportation and Environmental
Services, Office of Environmental
Quality, City of Alexandria,
Virginia

EPA-HQ-OAR-2009-0234-15884-A2

Joseph Otis
Minott

Clean Air Council

EPA-HQ-OAR-2009-0234-16121 - A1

Cynthia Bearer,
Board Chair

Children's Environmental Health
Network (CEHN)

EPA-HQ-OAR-2009-0234-16122-A1

Harold "Gus"
Frank

Forest County Potawatomi
Community (FCPC)

816


-------
12/08/11 DRAFT

EPA-HQ-OAR-2009-0234-16207-A1

Nancy F. Parks

Sierra Club

EPA-HQ-OAR-2009-0234-16402-A1

Joseph S. Hensel

Rochester Public Utilities

EP A-HQ-0 AR-2009-0234-16403 - A 1

Paul Bailey

American Coalition for Clean Coal
Electricity (ACCCE)

EPA-HQ-OAR-2009-0234-16404-A1

Charles D.
Connor

American Lung Association

EPA-HQ-OAR-2009-0234-16405-A1

Art Graham

Florida Public Service
Commission (FPSC)

EP A-HQ-0 AR-2009-0234-16469-A1

Bill Banig and
Jim Hunter

Unions for Jobs and the
Environment (UJAE)

EP A-HQ-0 AR-2009-0234-16513 - A1

Daniel C. Esty

Connecticut Department of Energy
and Environmental Protection

EP A-HQ-0 AR-2009-0234-16549-A1

Lance Brown et
al.

Partnership for Affordable Clean
Energy (PACE)

EP A-HQ-0 AR-2009-0234-16626-A1

Congressman
John D. Dingell,
et al.

Congress of the United States

EPA-HQ-OAR-2009-0234-16627-A1

Illona A.
Jeffcoat-Sacco

North Dakota Public Service
Commission

EP A-HQ-0 AR-2009-023 4-1663 0-A1

Ellen Rendulich

Citizens Against Ruining the
Environment (CARE)

EPA-HQ-OAR-2009-0234-16682-A1

Juliet Cohen

Upper Chattahoochee
Riverkeepers

EPA-HQ-OAR-2009-0234-16705-A2

William H.
Conrad

City of Newberry, Florida

EP A-HQ-0 AR-2009-0234-1673 8-A1

Leonard Levin

Electric Power Research Institute
(EPRI)

EPA-HQ-OAR-2009-0234-16822-A1

Senator James A.
Inhofe, et al.

Congress of the United States

EP A-HQ-0 AR-2009-0234-16824-A2

Chris Clark

Georgia Chamber of Commerce

EP A-HQ-0 AR-2009-0234-16826-A1

Brian Saylor

American Lung Association

EPA-HQ-OAR-2009-0234-16844-A1

John A. Arway

Pennsylvania Fish and Boat
Commission (PFBC)

EPA-HQ-OAR-2009-0234-16849-A1

Rebecca Heffren

Empire District Electric Company

EPA-HQ-OAR-2009-0234-16850-A2

Cindy B. Miller

Florida Public Service
Commission

EP A-HQ-0 AR-2009-0234-16856-A1

Tom Bloss

Pritchard Electric

EPA-HQ-OAR-2009-0234-16857-A1

Caroline Choi

Progress Energy

EP A-HQ-0 AR-2009-0234-16858-A1

R.D. Cross

Gilmer, TX

EPA-HQ-OAR-2009-0234-16859-A1

Leo M. Drozdoff

Environmental Council of the
States (ECOS)

EP A-HQ-0 AR-2009-0234-16861 - A1

Thomas R. Kuhn

Edison Electric Institute (EEI)

EPA-HQ-OAR-2009-0234-16872-A1

Tony Clark

National Association of
Regulatory Utility Commissioners

817


-------
12/08/11 DRAFT





(NARUC)

EPA-HQ-OAR-2009-0234-16873-A1

Thomas W.
McNamee

Public Utilities Commission Ohio
(PUCO)

EP A-HQ-0 AR-2009-0234-17003 - A 1

Scott H. Segal

Electric Reliability Coordinating
Council (ERCC)

EPA-HQ-OAR-2009-0234-17004-A1

Billy Ray Jones

City of Nashville, Arkansas

EPA-HQ-OAR-2009-0234-17022-A1

Charles Waldon

Town of Stonewall, Louisiana

EPA-HQ-OAR-2009-0234-17026-A1

David R.
Rockett, Jr.

Greater Bossier Economic
Development Foundation

EPA-HQ-OAR-2009-0234-17028-A1

Carson C. Joines

City of Carthage, Texas

EP A-HQ-0 AR-2009-0234-17055-A1

Nicholas A.
Brown

Southwest Power Pool, Inc. (SPP)

EP A-HQ-0 AR-2009-0234-17110-A1

Michael Bradley

Clean Energy Group's Clean Air
Policy Initiative

EP A-HQ-0 AR-2009-0234-17114-A1

Rosemary
Elebash

National Federation of
Independent Business (NFIB)

EP A-HQ-0 AR-2009-0234-17123 -A1

Andrew J. Such

Michigan Manufacturers
Association (MMA)

EP A-HQ-0 AR-2009-0234-1713 7-A1

Mike Arms

Association of Tennessee Valley
Governments (ATVG)

EP A-HQ-0 AR-2009-0234-17157-A1

Evelyn Fang

Leadership Council Alaska,
American Lung Association

EP A-HQ-0 AR-2009-0234-17174-A2

Myra C. Reece

Bureau of Air Quality, South
Carolina Department of Health
and Environmental Control
(DHEC)

EP A-HQ-0 AR-2009-0234-17191-A2

Terry Hogan

Wabash Valley Power Association
(WVPA)

EP A-HQ-0 AR-2009-0234-17197-A1

Paul Schulz

Platte River Power Authority

EPA-HQ-OAR-2009-0234-17254-A1

Public Hearing
in Atlanta, GA
on May 26, 2011



EP A-HQ-0 AR-2009-0234-17265-A1

Michael P.
Halpin

Division of Air Resource
Management, Florida Department
of Environmental Protection
(FDEP)

EP A-HQ-0 AR-2009-0234-17270

V. Watson

None

EPA-HQ-OAR-2009-0234-17278-A1

Donald H. Picard

Southeast Volusia Audubon
Society chapter of the National
Audubon Society

EP A-HQ-0 AR-2009-0234-17279

Mark Mueller

St. Petersburg chapter of the
National Audubon Society

EP A-HQ-0 AR-2009-0234-17281-A2

Kenneth J.
Schilling

Washington Electric Cooperative,
Inc.

818


-------
12/08/11 DRAFT

EPA-HQ-OAR-2009-0234-17283-A1

Carli Smith et al.

Cooper Environmental Services,
LLC (CES)

EPA-HQ-OAR-2009-0234-17291

Anonymous
public comment

None

EPA-HQ-OAR-2009-0234-17294

L. McClain

None

EPA-HQ-OAR-2009-0234- 17295-A2

L. J. Joey Durel,
Jr.,

Lafayette Consolidated
Government on behalf of
Lafayette Utilities System

EPA-HQ-OAR-2009-0234-17296-A2

Marshall D.
Moore

Chemtura Corporation

EPA-HQ-OAR-2009-0234-17297-A2

Orjiakor N.
Isiogu, Monica
Martinez, and
Greg R. White

Department of Licensing and
Regulatory Affairs, Michigan
Public Service Commission

EPA-HQ-OAR-2009-0234-17299-A2

George Carter

Paulding Putnam Electric
Cooperative, Inc.

EPA-HQ-OAR-2009-0234-17305-A2

Gerald Lauer

Consolidated Electric Cooperative,
Inc.

EPA-HQ-OAR-2009-0234-173 06-A2

Glenn W. Miller

Holmes-Wayne Electric
Cooperative, Inc.

EPA-HQ-OAR-2009-0234-17316-A2

B. Machaver

None

EPA-HQ-OAR-2009-0234-17381

Jon Hinck

Maine House of Representatives

EPA-HQ-OAR-2009-0234-173 83 -A 1

John T. Graves

Minnkota Power Cooperative, Inc.

EPA-HQ-OAR-2009-0234-173 85-A2

Floyd

DesChamps

Alliance to Save Energy

EPA-HQ-OAR-2009-0234-173 86-A2

Richard Velez

Taunton Municipal Lighting Plant
(TMLP)

EPA-HQ-OAR-2009-0234- 17400-A1

Eugene F.
Wallace and
Paul H.
Beckhusen

Coldwater Board of Public
Utilities, City of Coldwater,
Michigan

EPA-HQ-OAR-2009-0234-17401 -A1

Jay Vavricek and

Timothy

Luchsinger

City of Grand Island, Nebraska

EPA-HQ-OAR-2009-0234-17402-A1

Basil G.
Constantelos

Edison Mission Energy, LLC

EPA-HQ-OAR-2009-0234-17403-A1

Anthony N.
Jacobs

International Brotherhood of
Boilermakers, Iron Ship Builders,
Blacksmiths, Forgers and Helpers
and AFL-CIO (Boilermakers
Union)

EPA-HQ-OAR-2009-0234-17405-A1

Jennifer Lust

Brainerd Lakes Area Audubon
Society

EPA-HQ-OAR-2009-0234-17406-A1

Raymond Burns

Rogers-Lowell Area Chamber of
Commerce

819


-------
12/08/11 DRAFT

EPA-HQ-OAR-2009-0234-17408-A1

Public Hearing
in Chicago, IL
on May 24, 2011



EPA-HQ-OAR-2009-0234-17409-A1

Public Hearing
in Philadelphia,
PA on May 24,
2011



EPA-HQ-OAR-2009-0234-17608-A1

Winslow
Sargeant

Small Business Administration
(SB A)

EPA-HQ-OAR-2009-0234-17620-A1

S. William
Becker

National Association of Clean Air
Agencies (NACAA)

EPA-HQ-OAR-2009-0234-17621 -A1

Paul Chu

Electric Power Research Institute
(EPRI)

EPA-HQ-OAR-2009-0234-17622-A1

David Foerter

Institute of Clean Air Companies
(ICAC)

EPA-HQ-OAR-2009-0234-17623-A1

Brian H. Moeck

Large Public Power Council
(LPPC)

EPA-HQ-OAR-2009-0234- 17625-A1

Ronald Poltak

New England Interstate Water
Pollution Control Commission
(NEIWPCC)

EPA-HQ-OAR-2009-0234- 17626-A1

Robert G. Hilton

Power Technologies for
Government Affairs, Alstom

EPA-HQ-OAR-2009-0234-17627-A1

Raymond L.
Evans

FirstEnergy Corp. (FE)

EPA-HQ-OAR-2009-0234-17628-A1

Les Oakes

King & Spalding LLP on behalf of
Power4Georgians, LLC (P4G)

EPA-HQ-OAR-2009-0234-17629-A1

John V. Corra

Wyoming Department of
Environmental Quality

EPA-HQ-OAR-2009-0234-17637-A1

Ruthanne F.
Calabrese

Northeast Utilities System
Company (NUSCO)

EPA-HQ-OAR-2009-0234-1763 8-A1

James 0. Vick

Florida Electric Power
Coordinating Group, Inc. (FCG)

EPA-HQ-OAR-2009-0234-1763 9-A1

Terry E.

Branstad,

Governor

State of Iowa

EPA-HQ-OAR-2009-0234-17640-A1

Paul A. Yost

National Association of
Manufacturers (NAM)

EPA-HQ-OAR-2009-0234-17648-A2

Kathleen Barron

Exelon Corporation (Part 1 of 3)

EPA-HQ-OAR-2009-0234- 17654-A1

David E.
Meehan

Sunbury Generation LP

EPA-HQ-OAR-2009-0234-17655-A1

David M. Fraley

City Utilities of Springfield,
Missouri (CU)

EPA-HQ-OAR-2009-0234-17656-A1

Holly Propst

Western Business Roundtable

EPA-HQ-OAR-2009-0234- 17657-A1

Joan Small

Gilmer Area Chamber of
Commerce

EPA-HQ-OAR-2009-0234-1765 8-A1

Lynda Munkres,

Morris County, TX

820


-------
12/08/11 DRAFT



Judge



EPA-HQ-OAR-2009-0234-17659-A1

Kelly R. Hall

Real East Texas Longview
Chamber of Commerce

EPA-HQ-OAR-2009-0234-17660-A1

J. W. Fullen,
Mayor

City of Henderson, TX

EPA-HQ-OAR-2009-0234-17661 -A1

Charles Thomas

Carthage Economic Development
Corporation

EPA-HQ-OAR-2009-0234-17674-A1

Charles L.
Franklin

Akin Gump Strauss Hauer & Feld
LLP on behalf of Gila River
Indian Community

EPA-HQ-OAR-2009-0234-17675-A1

Brian Brazil

TransAlta Centralia Generation
LLC

EPA-HQ-OAR-2009-0234-17676-A1

Ellen Bloom et
al.

Consumers Union

EPA-HQ-OAR-2009-0234-17677-A1

Tim Mordhorst

Black Hills Corporation (BH)

EPA-HQ-OAR-2009-0234-17678-A1

Eric Redman

Summit Texas Clean Energy, LLC

EPA-HQ-OAR-2009-0234-17679-A1

David Evers

Biodiversity Research Institute
(BRI)

EPA-HQ-OAR-2009-0234- 17680-A1

David

Chadwick,

Mayor

City of Center, TX

EPA-HQ-OAR-2009-0234-17681 - A1

Farzie Shelton

Lakeland Electric

EPA-HQ-OAR-2009-0234-17682-A1

Steven C. Borell

Alaska Miners Association (AMA)

EPA-HQ-OAR-2009-0234-17683-A1

Tim Gestwicki
and Dick
Hamilton

North Carolina (NC) Wildlife
Federation and North Carolina
Camouflage Coalition

EPA-HQ-OAR-2009-0234- 17684-A1

Judy Sewell

Henderson Area Chamber of
Commerce

EPA-HQ-OAR-2009-0234-17685-A1

Bobby Beane

Kilgore Economic Development
Corporation

EPA-HQ-OAR-2009-0234- 17686-A1

Alan Grantham
and Connie
Ware

Marshall Chamber of Commerce

EPA-HQ-OAR-2009-0234-17689-A1

Rae E.
Cronmiller

The National Rural Electric
Cooperative Association
(NRECA)

EPA-HQ-OAR-2009-0234-17690-A1

Roger Caiazza

Environmental Energy Alliance of
New York, LLC

EPA-HQ-OAR-2009-0234-17691 -A1

John S. Lyons

Commonwealth of Kentucky,
Division for Air Quality

EPA-HQ-OAR-2009-0234-17692-A1

Daniel L. Juneau

Louisiana Association of Business
and Industry (LABI)

EPA-HQ-OAR-2009-0234-17693 - A 1

Stephen J.
Metcalf and
Susan

Longview Economic Development
Corporation

821


-------
12/08/11 DRAFT



Mazarakes-Gill



EPA-HQ-OAR-2009-0234-17694-A1

Lynda Rauscher

Mineola, Texas, Community
Development Department

EPA-HQ-OAR-2009-0234-17695-A1

Sue Henderson

Henderson Economic
Development Corporation

EPA-HQ-OAR-2009-0234-17696-A2

Linda Whelan

Dynegy, Inc.

EPA-HQ-OAR-2009-0234-17697-A1

Edward J. B.
Calvo

Governor of Guam on behalf of
Guam Power Authority (GPA)

EPA-HQ-OAR-2009-0234-17698-A1

Joaquin C.
Flores

Guam Power Authority (GPA)

EPA-HQ-OAR-2009-0234- 17699-A1

Alexander
Jackson

Fond du Lac Band of Lake
Superior Chippewa

EPA-HQ-OAR-2009-0234-17700-A1

R. E. Spradlin,
III, Mayor

Kilgore, TX

EPA-HQ-OAR-2009-0234-17701 -A1

Robin J. Lunt

National Association of
Regulatory Utility Commissioners
(NARUC)

EPA-HQ-OAR-2009-0234-17702-A1

Robert E.
Hunzinger

Gainesville Regional Utilities
(GRU)

EPA-HQ-OAR-2009-0234-17703-A1

Ronald W. Gore

Alabama Department of
Environmental Management
(ADEM)

EPA-HQ-OAR-2009-0234-17704-A1

Angela
Rodriguez

City Public Service (CPS Energy)

EPA-HQ-OAR-2009-0234- 17705-A1

Kevin Wanttaja

Salt River Project (SRP)

EPA-HQ-OAR-2009-0234- 17707-A1

Jack Pelfrey

Eufaula Barbour County Chamber
of Commerce

EPA-HQ-OAR-2009-0234- 17708-A1

E. F. Whitus,
Mayor

Mineola, Texas

EPA-HQ-OAR-2009-0234- 17709-A1

Bruce Caswell,
State Senator

State of Michigan

EPA-HQ-OAR-2009-0234-17710-A1

Senator Thomas
C. Ada

Committee on Utilities,
Transportation, Public Works, and
Veterans Affairs of the 31st Guam
Legislature

EPA-HQ-OAR-2009-0234-17711-A1

Paul Noe and

Robert

Glowinski

American Forest & Paper
Association (AF&PA) and
American Wood Council (AWC)

EPA-HQ-OAR-2009-0234-17712-A1

Leonard F.
Hopkins

Southern Illinois Power
Cooperative (SIPC)

EPA-HQ-OAR-2009-0234-17713 - A1

Niger Innis

Affordable Power Alliance

EPA-HQ-OAR-2009-0234-17714-A1

Nicholas M.
Dernik

Northern Indiana Public Service
Company (NIPSCO)

EPA-HQ-OAR-2009-0234-17715-A1

David E. Jones

Ohio Valley Electric Corporation
(OVEC)/Indiana Kentucky

822


-------
12/08/11 DRAFT





Electric Corporation (UCEC)

EPA-HQ-OAR-2009-0234-17716-A1

Dennis Lane

Stinson Morrison Hecker LLP on
behalf of Westar Energy, Inc.

EPA-HQ-OAR-2009-0234-17717-A1

Lorenz Walker,
Mayor

Bossier City, LA

EPA-HQ-OAR-2009-0234-17718-A1

Reid T. Clemmer

PPL Corporation

EPA-HQ-OAR-2009-0234-17719-A1

Martha E.
Rudolph

Colorado Department of Public
Health and Environment

EPA-HQ-OAR-2009-0234-17720-A1

Angila M.
Retherford

Vectren Corporation

EPA-HQ-OAR-2009-0234-17721 - A1

Winston &
Strawn LLP

on behalf of Chem-Mod LLC

EPA-HQ-OAR-2009-0234-17722-A1

Mary Jo Roth

Great River Energy (GRE)

EPA-HQ-OAR-2009-0234-17723 - A 1

David M. Fraley

City Utilities of Springfield,
Missouri (CU)

EPA-HQ-OAR-2009-0234- 17724-A1

John W. Dwyer

Lignite Energy Council (LEC)

EPA-HQ-OAR-2009-0234-17725-A1

Verne Shortell

NRG Energy, Inc.

EPA-HQ-OAR-2009-0234-17727-A1

John Proos, et
al., State Senate

State of Michigan

EPA-HQ-OAR-2009-0234- 17728-A1

Douglas J. Fulle

Oglethorpe Power Corporation

EPA-HQ-OAR-2009-0234- 17729-A1

Bruce Parker

Electric Energy, Inc. (EEI)

EPA-HQ-OAR-2009-0234-1773 0-A1

Barbara A. Walz

Tri-State Generation &
Transmission Association, Inc.

EPA-HQ-OAR-2009-0234-17731 -A 1

Parthenia B.
Evans and
Dennis Lane

Stinson Morrison Hecker LLP on
behalf of the Kansas City Board of
Public Utilities (BPU)

EPA-HQ-OAR-2009-0234- 17732-A1

Stephen B.
Etsitty

Navajo Nation Environmental
Protection Agency

EPA-HQ-OAR-2009-0234-1773 3 - A 1

Harold "Gus"
Frank and James
Crawford

Forest County Potawatomi
Community (FCPC)

EPA-HQ-OAR-2009-0234-17734-A1

Ed Williams

Novinda Corporation

EPA-HQ-OAR-2009-0234-1773 5-A1

Wayne E.
Penrod

Coalition of New Units

EPA-HQ-OAR-2009-0234-17736-A1

Ryan D. Elliott

Shumaker, Loop & Kendrick, LLP
on behlaf of Ohio Utility Group

EPA-HQ-OAR-2009-0234-1773 7-A1

Arie Hoekstra

Tucson Electric Power Company
(TEP)

EPA-HQ-OAR-2009-0234-1773 8-A1

Derek R.
McDonald

Baker Botts LLP on behalf of the
IP A Coleto Creek LLC (IP A)

EPA-HQ-OAR-2009-0234-1773 9-A1

Neal J. Cabral

McguireWoods LLP on behalf of
CONSOL Energy, Inc.

823


-------
12/08/11 DRAFT

EPA-HQ-OAR-2009-0234-17740-A1

William M.
Bumpers

Baker Botts L.L.P., on behalf of
Class of 1985 Regulatory
Response Group

EPA-HQ-OAR-2009-0234-17741 -A1

Stephen R.
Lindauer

The Association of Union
Constructors (TAUC)

EPA-HQ-OAR-2009-0234-17743-A1

E. Scott Pruitt,
Attorney General

State of Oklahoma

EPA-HQ-OAR-2009-0234- 17745-A1

Samuel S. Olens,
Attorney General

State of Georgia

EPA-HQ-OAR-2009-0234- 17747-A1

Krag Petterson

Pall Corporation

EPA-HQ-OAR-2009-0234- 17748-A1

Charles L. Hardy
Jr., Mayor

City of Commerce, Georgia

EPA-HQ-OAR-2009-0234-17749-A1

Jeff Lewis

Fitzgerald Water, Light & Bond
Commission

EPA-HQ-OAR-2009-0234- 17750-A1

Charlie Denham

Crisp County Power Commission

EPA-HQ-OAR-2009-0234-17751 - A1

William L.
Kovacs

U.S. Chamber of Commerce

EPA-HQ-OAR-2009-0234- 17752-A1

Mark Thoma

Otter Tail Power Company

EPA-HQ-OAR-2009-0234-17753-A1

Jason D. Bostic

West Virginia Coal Association
(WVCA)

EPA-HQ-OAR-2009-0234-17754-A1

Jeff McNelly

ARIPPA

EPA-HQ-OAR-2009-0234-17755-A1

Eddie Terrill

Oklahoma Department of
Environmental Quality (ODEQ)

EPA-HQ-OAR-2009-0234- 17756-A1

Paul M. Ling

Kansas City Power & Light
Company (KCP&L

EPA-HQ-OAR-2009-0234-17757-A1

Patrick
O'Loughlin

Buckeye Power, Inc.

EPA-HQ-OAR-2009-0234-17758-A1

Thomas R. Kuhn

Edison Electric Institute (EEI)

EPA-HQ-OAR-2009-0234-17760-A1

William M.
Bumpers

Baker Botts L.L.P., on behalf of
Class of 1985 Regulatory
Response Group

EPA-HQ-OAR-2009-0234-17761 -A1

Cathy S.
Woollums

Mid American Energy Holdings
Company

EPA-HQ-OAR-2009-0234-17763 - A 1

Camille Payne,
Mayor

Thomasville, GA

EPA-HQ-OAR-2009-0234-17765-A1

John T. Heard

The Virginia Coal Association,
Inc. (VCA)

EPA-HQ-OAR-2009-0234-17766-A1

Dennis M.
Grzezinski

Midwest Environmental
Advocates, Inc. (MEA)

EPA-HQ-OAR-2009-0234-17767-A1

PJ Becker

City of Springfield, Illinois - City
Water Light & Power (CWLP)

EPA-HQ-OAR-2009-0234-17768-A1

Michael A.
Livermore et al.

Institute for Policy Integrity, New
York University School of Law

EPA-HQ-OAR-2009-0234-17769-A1

Mike Roddy

Seminole Electric Cooperative,
Inc.

824


-------
12/08/11 DRAFT

EPA-HQ-OAR-2009-0234-17770-A1

Bruce W.
Ramme

We Energies

EPA-HQ-OAR-2009-0234-17771 - A1

Dave Martin

New Mexico Environment
Department (NMED)

EPA-HQ-OAR-2009-0234-17772-A1

Jo Anne Rau

Dayton Power and Light Company
(DP&L)

EPA-HQ-OAR-2009-0234-17773-A1

Leonard Levin

Electric Power Research Institute
(EPRI)

EPA-HQ-OAR-2009-0234- 17774-A1

Jay Hudson

Santee Cooper

EPA-HQ-OAR-2009-0234-17775

None

Utility Air Regulatory Group
(UARG)

EPA-HQ-OAR-2009-0234-17775-A1

Lee B. Zeugin et.
al Hunton and
Williams LLP

on behalf of Utility Air Regulatory
Group (UARG)

EPA-HQ-OAR-2009-0234- 17776-A1

Patricia D. Horn

Oklahoma Gas And Electric
Company (OGandE)

EPA-HQ-OAR-2009-0234- 17777-A1

Hunton and
Williams LLP

on behalf of Utility Air Regulatory
Group (UARG)

EPA-HQ-OAR-2009-0234- 17778-A1

Willie E. Burns,
Mayor

City of Washington, Georgia

EPA-HQ-OAR-2009-0234- 17779-A1

Albert Doughty,
Mayor

Town of Benton, Louisiana

EPA-HQ-OAR-2009-0234- 17780-A1

Mary Jo Graham

Oakmoss Education

EPA-HQ-OAR-2009-0234-17781 - A1

Hunton and
Williams LLP

on behalf of Utility Air Regulatory
Group (UARG)

EPA-HQ-OAR-2009-0234- 17782-A1

Rosemary
Elebash

National Federation of
Independent Business (NFIB)

EPA-HQ-OAR-2009-0234-17783-A1

Kenneth D.
Roberts

City of Barnesville, Georgia

EPA-HQ-OAR-2009-0234- 17784-A1

Hunton and
Williams LLP

on behalf of Utility Air Regulatory
Group (UARG)

EPA-HQ-OAR-2009-0234- 17785-A1

Hunton and
Williams LLP

on behalf of Utility Air Regulatory
Group (UARG)

EPA-HQ-OAR-2009-0234-17786-A1

Lauren Freeman

Hunton & Williams LLP on behalf
of Utility Air Regulatory Group

EPA-HQ-OAR-2009-0234-17787-A1

Lauren Freeman

Hunton & Williams LLP on behalf
of Utility Air Regulatory Group

EPA-HQ-OAR-2009-0234-17788-A1

Scott

Getzschman and
Derril Marshall

Fremont Department of Utilities,
Nebraska

EPA-HQ-OAR-2009-0234-17789-A2

Scott M. Lorey

Adirondack Council

EPA-HQ-OAR-2009-0234-17790-A2

William Rogers

DTE Energy

EPA-HQ-OAR-2009-0234-17791-A2

Robin J. Lunt

National Association of
Regulatory Utility Commissioners
(NARUC)

825


-------
12/08/11 DRAFT

EPA-HQ-OAR-2009-0234-17792-A1

L. J. "Joey"
Durel, Jr.

Lafayette Consolidated
Government on behalf of
Lafayette Utilities System et al.

EPA-HQ-OAR-2009-0234-17795-A1

Brian W. Green

GenOn Energy, Inc.

EPA-HQ-OAR-2009-0234-17796-A1

J. Jared Snyder

New York State Department of
Environmental Conservation
(NYSDEC)

EPA-HQ-OAR-2009-0234-17797-A1

El don Long,
Mayor

City of Lowell, Arkansas

EPA-HQ-OAR-2009-0234-17798-A1

William B.
Baumann

Wisconsin Department of Natural
Resources (WDNR)

EPA-HQ-OAR-2009-0234-17799-A1

Paul Bailey

American Coalition for Clean
Electricity (ACCCE)

EPA-HQ-OAR-2009-0234-17800

Steven C.
Whitworth

Ameren Corporation

EPA-HQ-OAR-2009-0234-17800-A1

Steven C.
Whitworth

Ameren Corporation

EPA-HQ-OAR-2009-0234-17801 - A1

Steve Meyers

General Electric Company (GE)

EPA-HQ-OAR-2009-0234-17803-A1

Robert D. Teetz

National Grid

EPA-HQ-OAR-2009-0234-17804-A1

Michael L.
Krancer

Pennsylvania Department of
Environmental Protection (DEP)

EPA-HQ-OAR-2009-0234-17805-A1

Abbie Krebsbach

Montana-Dakota Utilities
Company

EPA-HQ-OAR-2009-0234- 17806-A1

Henry R. Darwin

Arizona Department of
Environmental Quality (ADEQ)

EPA-HQ-OAR-2009-0234-17807

Thomas L.
Hernandez

Tampa Electric Company (TEC)

EPA-HQ-OAR-2009-0234-17807-A1

Thomas L.
Hernandez

Tampa Electric Company (TEC)

EPA-HQ-OAR-2009-0234-17808-A1

Michael Bradley

The Clean Energy Group

EPA-HQ-OAR-2009-0234-17809-A1

Mike Roddy

Seminole Electric Cooperative,
Inc.

EPA-HQ-OAR-2009-0234-17810-A1

Regina Hopper

America's Natural Gas Alliance
(ANGA)

EPA-HQ-OAR-2009-0234-17811 - A1

J. Dorgan and M.
D. Gibson
Lindblom on
behalf of
Michael
Churchman

Alabama Environmental Council
et al.

EPA-HQ-OAR-2009-0234-17812-A1

Robert D.
Bessette

Council of Industrial Boiler
Owners (CIBO)

EPA-HQ-OAR-2009-0234-17813 -A 1

Joseph G. Eutizi

San Miguel Electric Cooperative,
Inc.

EPA-HQ-OAR-2009-0234-17814-A1

James O. Vick

Gulf Power Company

826


-------
12/08/11 DRAFT

EPA-HQ-OAR-2009-0234-17815-A1

John W. Fainter,
Jr.

Association of Electric Companies
of Texas (AECT)

EPA-HQ-OAR-2009-0234-17816-A1

Michael L. Jones

Puget Sound Energy, Inc.

EPA-HQ-OAR-2009-0234-17817-A1

Wayne E.
Penrod

Sunflower Electric Power
Corporation

EPA-HQ-OAR-2009-0234-17818-A2

Ronald A.
Amirikian

State of Delware, Department of
Natural Resources &
Environmental Control, Division
of Air and Waste Management

EPA-HQ-OAR-2009-0234-17819-A2

Keith Harley

Environment Illinois, Chicago
Legal Clinic, Inc. on behalf of
Environmental Law and Policy
Center (ELPC)

EPA-HQ-OAR-2009-0234- 17820-A1

Pamela F.
Faggert

Dominion

EPA-HQ-OAR-2009-0234-17820-A2

Pamela F.
Faggert

Dominion

EPA-HQ-OAR-2009-0234-17821 - A1

John L. Stowell

Duke Energy

EPA-HQ-OAR-2009-0234-17822-A1

Richard Barr,
Mayor

Adel, GA

EPA-HQ-OAR-2009-0234-17823-A1

Woodrow
Wilson, Jr.

Parrish of Caddo

EPA-HQ-OAR-2009-0234-17824-A1

Peter B. Storey

Childersburg Chamber of
Commerce

EPA-HQ-OAR-2009-0234- 17825-A1

Keith Brady,
Mayor

Newnan, GA

EPA-HQ-OAR-2009-0234- 17826-A1

Peter L. Banks,
Mayor

Barnesville, GA

EPA-HQ-OAR-2009-0234-17827-A1

J.D. Herring

Quitman, GA

EPA-HQ-OAR-2009-0234- 17829-A1

Fred Hlava,

Gordon, NE

EPA-HQ-OAR-2009-0234-17830-A1

Dan Leise

Cedar-Knox Public Power District
(CKPPD)

EPA-HQ-OAR-2009-0234-17831 -A 1

Neal D. Suess

Loup River Public Power District

EPA-HQ-OAR-2009-0234-1783 3 - A1

David P. Hackett
and Jessica
Mitchell Wicha,
Baker &
McKenzie LLP

on behalf of Michael A. Gardner
Gypsum Association

EPA-HQ-OAR-2009-0234-17834-A1

Jon Bruning

State of Nebraska et al.

EPA-HQ-OAR-2009-0234-1783 5-A1

David M. Fraley

City Utilities of Springfield,
Missouri (CU)

EPA-HQ-OAR-2009-0234-17836

John T. Suttles

Southern Environmental Law
Center (SELC)

EPA-HQ-OAR-2009-0234-17836-A1

John T. Suttles,
Jr.,

Southern Environmental Law
Center (SELC) and Southeast

827


-------
12/08/11 DRAFT





Environmental Organizations

EP A-HQ-0 AR-2009-0234-1783 7-A2

Thomas
Holbrook,
Illinois State
Representative

Illinois General Assembly, 113th
District

EPA-HQ-OAR-2009-0234-1783 8-A2

R. J. Shaffer

Scrubgrass Generating Company
LP.

EP A-HQ-0 AR-2009-0234-1783 9-A2

Wallace L.
Taylor

Sierra Club Iowa Chapter

EPA-HQ-OAR-2009-0234-17840-A2

William D.
Bissett

Kentucky Coal Association (KCA)

EPA-HQ-OAR-2009-0234-17841-A2

Craig S.
Campbell

Lafarge North America-Cement
Division

EPA-HQ-OAR-2009-0234-17842-A2

Kevin Cramer

North Dakota Public Service
Commission (NDPSC) et al.

EPA-HQ-OAR-2009-0234-17843 -A2

Arthur N. Marin

Northeast States for Coordinated
Air Use Management
(NESCAUM)

EPA-HQ-OAR-2009-0234-17844-A2

Mindy Lubber

Ceres

EPA-HQ-OAR-2009-0234-17845-A2

C. Richard Neff

Cogentrix Energy, LLC

EPA-HQ-OAR-2009-0234-17846-A2

Alex Jackson

Fond du Lac Band of Lake
Superior Chippewa

EPA-HQ-OAR-2009-0234-17848-A2

Travis J. Blake

Division of Air Pollution Control,
Tennessee Department of
Environment and Conservation

EPA-HQ-OAR-2009-0234-17849-A2

Garry A. Mbiad

Guernsey-Muskingum Electric
Cooperative, Inc.

EPA-HQ-OAR-2009-0234-17850-A1

Jeff A. McNelly

ARIPPA

EPA-HQ-OAR-2009-0234-17851-A2

Melvin E.
Keener

Coalition for Responsible Waste
Incineration (CRWI)

EPA-HQ-OAR-2009-0234- 17852-A2

Gregory C.
Staple

American Clean Skies Foundation
(ACSF)

EP A-HQ-0 AR-2009-0234-17853-A2

Matt Most

Encana Natural Gas, Inc.

EPA-HQ-OAR-2009-0234-17854-A1

Kristina Curtis

Green Century Capital
Management

EP A-HQ-0 AR-2009-0234-17855-A2

David A.
Kellermeyer

Northern Star Generation, LLC

EPA-HQ-OAR-2009-0234-17856-A2

Scott J. Nally

Ohio Environmental Protection
Agency (Ohio EPA)

EPA-HQ-OAR-2009-0234-17857-A2

John A. Benedict

West Virginia Department of
Environmental Protection,
Division of Air Quality

EPA-HQ-OAR-2009-0234-17866-A1

Jackie L.
Wilson, Mayor

City of Douglas, Georgia

828


-------
12/08/11 DRAFT

EPA-HQ-OAR-2009-0234-17867-A2

Stephen
Quennoz

Portland General Electric
Company (PGE)

EPA-HQ-OAR-2009-0234-17868-A2

Alex Hofmann
and Theresa
Pugh

American Public Power
Association (APPA)

EPA-HQ-OAR-2009-0234- 17869-A1

Seth Jacobson

Mercury Free Partnership (MFP)

EPA-HQ-OAR-2009-0234-17870-A2

Randall R.
LaBauve

NextEra Energy Inc.

EPA-HQ-OAR-2009-0234-17871-A2

Dennis P.
Laybourn

Newmont Nevada Energy
Investment, LLC (NNEI)

EPA-HQ-OAR-2009-0234-17872-A2

W. Lawrence
Givens

Umatilla County Board of County
Commissioners, Oregon

EPA-HQ-OAR-2009-0234-17873 -A2

Frank P. Prager

Xcel Energy, Inc.

EPA-HQ-OAR-2009-0234- 17875-A1

Susan Lyon

Center for American Progress

EPA-HQ-OAR-2009-0234-17876-A2

Deborah Fohr
Levchak

Basin Electric Power Cooperative
(BEPC)

EPA-HQ-OAR-2009-0234- 17877-A1

Todd A. Tolbert

Associated Electric Cooperative,
Inc.

EPA-HQ-OAR-2009-0234-17877-A2

Todd A. Tolbert

Associated Electric Cooperative,
Inc.

EPA-HQ-OAR-2009-0234-17878-A3

Ben Yamagata

Coal Utilization Research Council
(CURC)

EPA-HQ-OAR-2009-0234-17879-A2

Thomas S.
Howard

Domtar

EPA-HQ-OAR-2009-0234- 17880-A2

Adrienne
Esposito

Citizens Campaign for the
Environment (CCE)

EPA-HQ-OAR-2009-0234-17881-A2

Louis P.
Pocalujka

Consumers Energy

EPA-HQ-OAR-2009-0234- 17882-A2

Shelley Vinyard

Environment America et al.

EPA-HQ-OAR-2009-0234-17883-A2

Kevin Cahill

IPR-GDF SUEZ Energy
Generation NA, Inc.

EPA-HQ-OAR-2009-0234- 17884-A2

Peter Glaser

Troutman Sanders LLP on be half
of Peabody Energy Company

EPA-HQ-OAR-2009-0234-17885-A1

Leonard F.
Hopkins

Southern Illinois Power
Cooperative (SIPC)

EPA-HQ-OAR-2009-0234- 17886-A2

John W. Myers

Tennessee Valley Authority
(TV A)

EPA-HQ-OAR-2009-0234- 17887-A2

James E. Melia

Pennsylvania Public Utility
Commission (PAPUC)

EPA-HQ-OAR-2009-0234- 17889-A1

Kevin Pollard

Norris Public Power

EPA-HQ-OAR-2009-0234- 17890-A1

Duncan
Kinchelow

Missouri Association of Municipal
Utilities

EPA-HQ-OAR-2009-0234-17891 - A1

William J.
Yearta, Mayor

Sylvester, GA

EPA-HQ-OAR-2009-0234- 17892-A1

Clay A. Gibbs

Cornhusker Public Power District

829


-------
12/08/11 DRAFT

EPA-HQ-OAR-2009-0234-17895-A1

Senator Jack
Reed

United States Senate

EPA-HQ-OAR-2009-0234-17897-A1

Greg Thompson,
Mayor

Monroe, GA

EPA-HQ-OAR-2009-0234-17898-A1

Kathy French

Longleaf Energy Associates, LLC

EPA-HQ-OAR-2009-0234-17901-A2

Michael T.W.
Carey

Ohio Coal Association (OCA)

EPA-HQ-OAR-2009-0234-17902-A2

Douglas R. Kopp

Alliant Energy Corporate Services,
Inc.

EPA-HQ-OAR-2009-0234-17903-A2

Lei and M.
Searles

Iowa Environmental Council
(IEC)

EPA-HQ-OAR-2009-0234-17904-A3

Leslie Garrett
Allen

Balch & Bingham LLP on behalf
of Luminant

EPA-HQ-OAR-2009-0234-17909-A1

Keith M.
Stephens

PowerSouth Energy Cooperative

EPA-HQ-OAR-2009-0234-17910-A1

Robert T.
Hunnicutt, Sr.

Fort Valley Utility Commission,
Fort Valley, CA

EPA-HQ-OAR-2009-0234-17911-A1

Floyd Gilzow

Missouri Joint Municipal Electric
Utility Commission (MJMEUC)

EPA-HQ-OAR-2009-0234-17912-A1

Les Oakes and
Cynthia Stroman

King & Spalding LLP on behalf of
IPP Coalition

EPA-HQ-OAR-2009-0234-17913 - A1

Russ Baker

Omaha Public Power District
(OPPD)

EPA-HQ-OAR-2009-0234-17914-A1

R. L. Killion

Babcock & Wilcox Power
Generation Group, Inc. (B&W)

EPA-HQ-OAR-2009-0234-17915-A1

Alice Edwards

Division of Air Quality, Alaska
Department of Environmental
Conservation (ADEC)

EPA-HQ-OAR-2009-0234-17916-A1

John Wilkinson

Province of Ontario Ministry of
the Environment, Canada

EPA-HQ-OAR-2009-0234-17917-A1

Matthew H.
Mead, Governor

State of Wyoming

EPA-HQ-OAR-2009-0234-17918-A1

Dustin McDaniel

Arkansas Attorney General's
Office

EPA-HQ-OAR-2009-0234-17919-A1

Scott H. Segal

Electric Reliability Coordinating
Council (ERCC)

EPA-HQ-OAR-2009-0234-17920-A1

Joseph Hantz

Entergy Services, Inc.

EPA-HQ-OAR-2009-0234-17921 - A1

Indra Frank

Improving Kids' Environment

EPA-HQ-OAR-2009-0234- 17922-A1

Ross Gould

Environmental Advocates of New
York

EPA-HQ-OAR-2009-0234-17923 - A 1

Craig Bressan

Prairie State Generating Company,
LLC (PSGC)

EPA-HQ-OAR-2009-0234-17924-A1

James C. Welsh

Kissimmee Utility Authority
(KUA)

EPA-HQ-OAR-2009-0234- 17925-A2

Bill Matthews

Cleco Power LLC

830


-------
12/08/11 DRAFT

EPA-HQ-OAR-2009-0234-17926-A2

Derf Johnson

Montana Environmental
Information Center (MEIC)

EPA-HQ-OAR-2009-0234-17927-A2

Grant Rodway

Bison Engineering, Inc.

EPA-HQ-OAR-2009-0234-17928-A2

Paul J. Allen

Constellation Energy

EPA-HQ-OAR-2009-0234-17929-A2

James Pew

Earthjustice

EPA-HQ-OAR-2009-0234-17930-A2

Michael J. Nasi

Jackson Walker L.L.P. on behalf
of Gulf Coast Lignite Coalition
(GCLC)

EPA-HQ-OAR-2009-0234-17931-A2

William D.
Bissett

Kentucky Coal Association (KCA)

EPA-HQ-OAR-2009-0234-17973-A1

John A. Paul

Regional Air Pollution Control
Agency (RAPCA) of Dayton,
Ohio

EPA-HQ-OAR-2009-0234- 17974-A1

James 0. Vick

Florida Electric Power
Coordinating Group, Inc. (FCG)

EPA-HQ-OAR-2009-0234- 17975-A1

Eric Schaeffer

Environmental Integrity Project
(HP)

EPA-HQ-OAR-2009-0234-18014-A2

Larry J. Koshire

Rochester Public Utlities (RPU)

EPA-HQ-OAR-2009-0234-18015-A2

Edward Z. Fox

Arizona Public Service Company
(APS)

EPA-HQ-OAR-2009-0234-18016-A2

John D. Free

Alabama Public Service
Commission (APSC)

EPA-HQ-OAR-2009-0234-18017-A2

David V.
Modeer

Central Arizona Water
Conservation District (CAWCD)

EPA-HQ-OAR-2009-0234-18018-A2

Barry Moline

Florida Municipal Electric
Association (FMEA)

EPA-HQ-OAR-2009-0234-18019-A2

Susan Ackerman
and John Savage

Oregon Public Utility Commission
(OPUC)

EPA-HQ-OAR-2009-0234- 18020-A2

Jonathan Oliver

Arkansas Electric Cooperative
Corporation (AECC)

EPA-HQ-OAR-2009-0234-18021-A2

James M.
Landreth

South Carolina Electric and Gas
Company (SCE&G)

EPA-HQ-OAR-2009-0234- 18022-A2

Ross Gould

Environmental Advocates of New
York

EPA-HQ-OAR-2009-0234-18023

Chris Hob son

Southern Company

EPA-HQ-OAR-2009-0234-18023-A2

Chris M. Hob son

Southern Company

EPA-HQ-OAR-2009-0234- 18024-A2

John P. Reese

US Power Generating Company
(USPG)

EPA-HQ-OAR-2009-0234- 18025-A2

EricB. Svenson

PSEG Services Corporation

EPA-HQ-OAR-2009-0234- 18026-A2

Kevin Schmidt

Ohio Manufacturers' Association
(OMA)

EPA-HQ-OAR-2009-0234- 18027-A2

Vickie Patton

Environmental Defense Fund
(EDF)

EPA-HQ-OAR-2009-0234-18028

J. Butera

Environmental Defense Fund
(EDF)

831


-------
12/08/11 DRAFT

EPA-HQ-OAR-2009-0234-18029-A2

Thomas M.
Gibbons

Jersey City Environmental
Commission

EPA-HQ-OAR-2009-0234-18030-A2

Bill Schuette

State of Michigan Attorney
General Office

EPA-HQ-OAR-2009-0234-18031-A2

Michael G.
Cashin

Minnesota Power (ALLETE)

EPA-HQ-OAR-2009-0234-18032-A2

Jim Weeks

Michigan Municipal Electric
Association (MMEA)

EPA-HQ-OAR-2009-0234-1803 3 - A2

Thomas C. Perry

National Mining Association
(NMA)

EPA-HQ-OAR-2009-0234- 18034-A2

Mark R. Vickery

Texas Commission on
Environmental Quality (TCEQ)

EPA-HQ-OAR-2009-0234- 18034-A3

Mark R. Vickery

Texas Commission on
Environmental Quality (TCEQ)

EPA-HQ-OAR-2009-0234-1803 5-A2

Lauren Freeman,
et al. Hunton &
Williams LLP

Utility Air Regulatory Group
(UARG)

EPA-HQ-OAR-2009-0234-18036-A2

Aaron Flynn,
Hunton &
Williams LLP

Utility Air Regulatory Group
(UARG)

EPA-HQ-OAR-2009-0234-18037-A2

Douglas L.
Biden

Electric Power Generation
Association (EPGA)

EPA-HQ-OAR-2009-0234-1803 8-A2

Justin M.
Nickels

City of Manitowoc Public
Utilities, Wisconsin

EPA-HQ-OAR-2009-0234-18039-A2

Kenneth L.
Kimmell

Massachusetts Department of
Environmental Protection
(MassDEP)

EPA-HQ-OAR-2009-0234-18043-A2

Allison D. Beals

Adirondack Mountain Club
(ADK)

EPA-HQ-OAR-2009-0234-18051-A2

Greg Schaefer

Arch Coal, Inc. (ACI)

EPA-HQ-OAR-2009-0234- 18248-A2

Joseph

Mendelson III

National Wildlife Federation
(NWF)

EPA-HQ-OAR-2009-0234-18414-A1

Larry L. Guest,
Mayor

City of Elberton, Georgia

EPA-HQ-OAR-2009-0234-18415-A1

W.Kurt
Foreman

North Louisiana Economic
Partnership (NLEP)

EPA-HQ-OAR-2009-0234-18416-A1

Greg Hines,
Mayor

City of Rogers, Arkansas

EPA-HQ-OAR-2009-0234-18417-A1

Patsy Meek

Panola County Economic
Development Corporation

EPA-HQ-OAR-2009-0234-18418-A1

Doug Sprouse,
Mayor

City of Springdale, Arkansas

EPA-HQ-OAR-2009-0234-18419-A1

Jennifer G.
Trammell

Greater Shelby County Chamber
of Commerce

EPA-HQ-OAR-2009-0234-18420-A1

Perry Webb

Springdale Chamber of Commerce

EPA-HQ-OAR-2009-0234-18421-A2

Susanne Brooks

Environmental Defense Fund

832


-------
12/08/11 DRAFT





(EDF)

EPA-HQ-OAR-2009-0234-18422-A1

Ted Hampton

Utah Associated Municipal Power
Systems (UAMPS)

EPA-HQ-OAR-2009-0234-18422-A2

Ted Hampton

Utah Associated Municipal Power
Systems (UAMPS)

EP A-HQ-0 AR-2009-0234-18423 - A2

David
Bookbinder

Julander Energy Company

EPA-HQ-OAR-2009-0234-18424-A2

J. Nathan Noland

Indiana Coal Council, Inc.

EPA-HQ-OAR-2009-0234-18425-A2

Erika Padgett

Clean Wisconsin, et al.

EPA-HQ-OAR-2009-0234-18426-A2

G. Vinson
Hellwig

Michigan Department of
Environmental Quality (MDEQ)

EPA-HQ-OAR-2009-0234-18427-A2

Kerry Kelly

Waste Management (WM)

EPA-HQ-OAR-2009-0234-18428-A2

Caroline Choi

Progress Energy

EPA-HQ-OAR-2009-0234-18429-A2

Coment
submitted by
Brian L. Warner

Wolverine Power Supply
Cooperative, Inc. (WPSCI)

EP A-HQ-0 AR-2009-0234-1843 0-A2

Robert F.
McDonnell

Commonwealth of Virginia

EP A-HQ-0 AR-2009-0234-18431-A1

John Blair

Valley Watch, Inc.

EPA-HQ-OAR-2009-0234-18432-A2

Adam H. Cutler

Public Interest Law Center of
Philadelphia

EP A-HQ-0 AR-2009-0234-1843 3 - A2

Joaquin C.
Flores, P.E.

Guam Power Authority (GPA)

EP A-HQ-0 AR-2009-0234-1843 3 - A3

Joaquin C.
Flores, P.E.

Guam Power Authority (GPA)

EP A-HQ-0 AR-2009-0234-1843 3 - A4

Joaquin C.
Flores, P.E.

Guam Power Authority (GPA)

EPA-HQ-OAR-2009-0234-18434-A2

David Gardiner

The Alliance for Industrial
Efficiency

EPA-HQ-OAR-2009-023 4-1843 5-A2

American
Academy of
Pediatrics et al.

American Lung Association et al.

EP A-HQ-0 AR-2009-0234-1843 6-A2

Jenny Dorgan

Alabama Rivers Alliance

EP A-HQ-0 AR-2009-0234-18437-A1

Patrick L. Pope

Nebraska Public Power District

EP A-HQ-0 AR-2009-0234-1843 8-A2

Vickie Patton

Environmental Defense Fund
(EDF)

EP A-HQ-0 AR-2009-0234-1843 9-A2

Lisa Jacobson

Business Council for Sustainable
Energy (BCSE)

EPA-HQ-OAR-2009-0234-18440-A2

Dustin McCaniel

Arkansas Attorney General's
Office

EP A-HQ-0 AR-2009-0234-18441 - A2

Craig Glazer

PJM Interconnection, L.L.C.

EP A-HQ-0 AR-2009-0234-18442-A1

Michael G.
Dowd

Virginia Department of
Environmental Quality (VADEQ)

EP A-HQ-0 AR-2009-0234-18443-A1

Michalene Reilly

Hoosier Energy Rural Electric

833


-------
12/08/11 DRAFT





Cooperative, Inc.

EPA-HQ-OAR-2009-0234-18444-A2

William
0'Sullivan, P.E.

State of New Jersey Department of
Environmental Protection

EPA-HQ-OAR-2009-0234-18445-A2

Edward F. Miller

American Lung Association
(ALA)

EPA-HQ-OAR-2009-0234-18446-A2

Thomas Home

State of Arizona et al.

EPA-HQ-OAR-2009-0234-18447-A2

Brian Trower

Ames Municipal Electric System

EPA-HQ-OAR-2009-0234-18448-A2

Craig A. Glazer

PJM Interconnection, L.L.C. et al.

EPA-HQ-OAR-2009-0234-18449-A2

Frank Schaedlich

Tekran Instruments Corporation

EPA-HQ-OAR-2009-0234-18450-A2

Donald Neal

Calpine Corporation

EPA-HQ-OAR-2009-0234-18477-A3

Ronald R. Cox

Hawaiian Electric Company, Inc.

EPA-HQ-OAR-2009-0234-18478-A1

Lois Capps, et al.

Congress of the United States

EPA-HQ-OAR-2009-0234-18480-A1

Neal F. Niedfeldt

City of Beatrice, Nebraska

EPA-HQ-OAR-2009-0234-18481-A1

William I.
McLarty, Mayor

City of South Sioux City,
Nebraska

EPA-HQ-OAR-2009-0234-18482-A1

Ann H.

Campbell,

Mayor

Mayor's Office, City of Ames,
Iowa

EPA-HQ-OAR-2009-0234-18483-A2

Larry G. Carlson

Tenaska, Inc.

EPA-HQ-OAR-2009-0234-18484-A2

Steven C. Borell

Alaska Miners Association (AMA)

EPA-HQ-OAR-2009-0234-18486-A2

Mark Maslyn

American Farm Bureau Federation

EPA-HQ-OAR-2009-0234-18487-A2

Sierra Club, et
al.

Sierra Club, et al.

EPA-HQ-OAR-2009-0234-18488-A2

Edward L.
Kropp

Midwest Ozone Group (MOG)

EPA-HQ-OAR-2009-0234-18489-A2

Marion Loomis

Wyoming Mining Association
(WMA)

EPA-HQ-OAR-2009-0234-18497-A2

Jolene M.
Thompson

American Municipal Power, Inc.
(AMP)

EPA-HQ-OAR-2009-0234-18498-A2

Jerry Purvis

East Kentucky Power Cooperative,
Inc. (EKPC)

EPA-HQ-OAR-2009-0234-18499-A2

Sal LoBianco

Muscatine Power and Water

EPA-HQ-OAR-2009-0234-18500-A2

Climate Policy
Group (CPG)

Climate Policy Group (CPG)

EPA-HQ-OAR-2009-0234-18501 - A2

Tyler Edgar

National Council of Churches

EPA-HQ-OAR-2009-0234-18502-A2

Late Miguel A.
Cordero Lopez

Puerto Rico Electric Power
Authority (PREPA)

EPA-HQ-OAR-2009-0234-18538-A2

Donna L. Nelson

Public Utility Commission of
Texas (Texas PUC)

EPA-HQ-OAR-2009-0234-18539-A1

Al DePaoli

AES Corporation

EPA-HQ-OAR-2009-0234-18540-A2

Louis J. Manuel
Jr.

Ak-Chin Indian Community

EPA-HQ-OAR-2009-0234-18541-A1

J. Fitzgerald and

None

834


-------
12/08/11 DRAFT



C. R. de Azua



EPA-HQ-OAR-2009-0234-18575-A1

Heartland
Consumers
Power District

Heartland Consumers Power
District

EPA-HQ-OAR-2009-0234-18576-A2

Sherri Bulkley,
et al.

American Lung Association in
Hawaii

EPA-HQ-OAR-2009-0234-18590-A2

Robin Grant

American Lung Association in
Tennessee (ALATN)

EPA-HQ-OAR-2009-0234-18644-A2

S. Nelson Jr.

None

EPA-HQ-OAR-2009-0234-18666-A1

P. Difani

None

EPA-HQ-OAR-2009-0234-18705-A1

Michael P.
Marcotte

City of Alexandria, Louisiana

EPA-HQ-OAR-2009-0234-18706-A1

Bucky Johnson,
Mayor

City of Norcross, Georgia

EPA-HQ-OAR-2009-0234-18707-A2

Linda McGrath

American Lung Association in
Idaho

EPA-HQ-OAR-2009-0234-18716-A2

Taylor A. Davis
III, Patty Unfred
and Matthew
Walker

American Lung Association in
Oregon

EPA-HQ-OAR-2009-0234-18721-A2

Jon Breiner, et
al.

American Lung Association in
Washington

EPA-HQ-OAR-2009-0234- 18749-A2

Mike Moody

American Lung Association in
Kentucky

EPA-HQ-OAR-2009-0234- 18750-A2

Harry Perlstadt

American Lung Association in
Michigan

EPA-HQ-OAR-2009-0234-18751 - A2

William Lawson
and Jesse Neeley

American Lung Association in
Tennessee

EPA-HQ-OAR-2009-0234- 18759-A2

Rick

MacCornack

Washington Asthma Initiative
(WAI)

EPA-HQ-OAR-2009-0234- 18785-A2

Eddy Young

Optim Energy LP, Twin Oaks

EPA-HQ-OAR-2009-0234- 18820-A1

M. Stiefermann

Central Electric Power
Cooperative

EPA-HQ-OAR-2009-0234-18823-A2

John Cloud

American Lung Association in
Ohio

EPA-HQ-OAR-2009-0234-18831-A1

Berdell Knowles

JEA

EPA-HQ-OAR-2009-0234- 18894-A1

Ric Hall, Mayor

City of Blakely, Georgia

EPA-HQ-OAR-2009-0234- 18897-A2

Daniel Sutton

American Lung Association in
Ohio (ALAO)

EPA-HQ-OAR-2009-0234-18898-A2

Linn Billingsley

American Lung Association,
Nevada

EPA-HQ-OAR-2009-0234- 18899-A2

Marlis Hadley

American Lung Association, New
Mexico

EPA-HQ-OAR-2009-0234- 18900-A2

Caroline
Moassessi

American Lung Association,
Nevada

835


-------
12/08/11 DRAFT

EPA-HQ-OAR-2009-0234-18901 - A2

Andy Boyce

American Lung Association,
Nevada

EPA-HQ-OAR-2009-0234-18907-A2

Charles D.
Bennett

Marathon Petroleum Company LP

EPA-HQ-OAR-2009-0234-18924-A1

Jim Hawks

City of North Platte

EPA-HQ-OAR-2009-0234-18930-A2

Connie Shawler
et al.

American Lung Association in
Arizona

EPA-HQ-OAR-2009-0234-18933-A2

Michael S.
Hubbard

National Council of Textile
Organizations (NCTO)

EPA-HQ-OAR-2009-0234- 18934-A2

Nicky Sheats,
Esq.

New Jersey Environmental Justice
Alliance (NJEJA)

EPA-HQ-OAR-2009-0234-18935-A2

Jon Howard

Weston Solutions, Inc.

EPA-HQ-OAR-2009-0234-18936-A1

Hays Arnold,
Mayor

City of Thomaston, GA

EPA-HQ-OAR-2009-0234-18937-A1

Kimberly C.
Carter, Mayor

City of Covington, GA

EPA-HQ-OAR-2009-0234- 18944-A1

Charles
Sherwood

City of Ellaville, GA

EPA-HQ-OAR-2009-0234-18961-A2

Meg Voorhes

US SIF - The Forum for
Sustainable and Responsible
Investment

EPA-HQ-OAR-2009-0234-18963-A2

Daniel Traynor

Northampton Generating
Company, L.P

EPA-HQ-OAR-2009-0234-18964-A2

CONSOL
Energy Inc.

CONSOL Energy Inc.

EPA-HQ-OAR-2009-0234-19032-A1

James M.
Andrew

Arizona Electric Power
Cooperative, Inc. (AEPCO)

EPA-HQ-OAR-2009-0234-1903 3 - A 1

Samuel H.
Bruntz

Alcoa Power Generating, Inc.
(APGI)

EPA-HQ-OAR-2009-0234- 19040-A1

D. S. McKeown

None

EPA-HQ-OAR-2009-0234-19041 -A1

Steven K.
Nelson

The Frontier Power Company

EPA-HQ-OAR-2009-0234-19042-A2

James Parkhurst

EOP Foundation

EPA-HQ-OAR-2009-0234-19094-A1

Michael C.
Stiefermann

Central Electric Power
Cooperative (CEPC)

EPA-HQ-OAR-2009-0234-19101 -A 1

James J. Egge

Audubon Chapter of Minneapolis

EPA-HQ-OAR-2009-0234-19111-A1

Linda

Vanderveen

Conservation Chair, Hernando
Audubon of Florida

EPA-HQ-OAR-2009-0234-19114-A1

John M.
McManus

American Electric Power (AEP)

EPA-HQ-OAR-2009-0234-19120-A1

Angelique Oliger

Indianapolis Power & Light
Company (IPL)

EPA-HQ-OAR-2009-0234-19121 -A1

Jon A. Finlinson

Intermountain Power Service
Corporation (IPSC)

EPA-HQ-OAR-2009-0234-19122-A1

Mark J. Sedlacek

Los Angeles Department of Water

836


-------
12/08/11 DRAFT





and Power (LADWP)

EPA-HQ-OAR-2009-0234-19123 - A1

Markus I. Bryant

Lorain-Medina Rural Electric
Cooperative, Inc.

EP A-HQ-0 AR-2009-0234-19143 - A 1

John (no
surname
provided)

None

EPA-HQ-OAR-2009-0234-19145-A1

Juan M. Cofield

National Association for the
Advancement of Colored People
(NAACP)

EPA-HQ-OAR-2009-0234-19199-A1

Heath R.
VanNatter

House of Representative, State of
Indiana

EPA-HQ-OAR-2009-0234- 19205-A1

L. Garvey

None

EPA-HQ-OAR-2009-0234- 19209-A1

Markus I. Bryant

North Central Electric
Cooperative, Inc.

EPA-HQ-OAR-2009-0234-19210-A1

Richard H.
Baker

Pelican Island Audubon Society

EPA-HQ-OAR-2009-0234-19211-A1

Joseph Croce

Virginia Manufacturers
Association (VMA)

EPA-HQ-OAR-2009-0234-19212-A2

James D.
Atterholt

Indiana Utility Regulatory
Commission (IURC) et al.

EPA-HQ-OAR-2009-0234-19213 - A1

J. Michael
Houston, Mayor

City of Springfield, Illinois

EPA-HQ-OAR-2009-0234-19214-A1

Willie R. Taylor,
Director

United States Department of the
Interior

EP A-HQ-0 AR-2009-0234-19225-A1

Mike Godwin

Orange Audubon Society

EP A-HQ-0 AR-2009-0234-19296-A1

Richard H.
Bremer

Greater Shreveport Chamber of
Commerce

EPA-HQ-OAR-2009-0234-19506-A1

Thomas W.
Easterly

Indiana Department of
Environmental Management

EPA-HQ-OAR-2009-0234-19540

Ann Brewster
Weeks

Clean Air Task Force, et al.

EPA-HQ-OAR-2009-0234- 19549-A1

David Theiss,
Mayor

City of Ellaville, Georgia

EP A-HQ-0 AR-2009-0234-19559-A1

C. Neil Mayer

City of Whigam, Georgia

EPA-HQ-OAR-2009-0234-19560-A1

Lemuel 0.
Edwards

Albany Water Gas & Light
Commission, Albany, Georgia

EPA-HQ-OAR-2009-0234- 19564-A1

Jamey D.
Pankoke

Perennial Public Power District

EP A-HQ-0 AR-2009-0234-19565-A1

Brian

Lukasiewicz

Howard Greeley Rural Public
Power District

EP A-HQ-0 AR-2009-0234-19566-A1

L. J. Joey Durel,
Jr.

Lafayette Utilities System,
Louisianna

EPA-HQ-OAR-2009-0234-19574-A1

Thomas E.
Rudloff

Elkhorn Rural Public Power
District

EP A-HQ-0 AR-2009-0234-19580-A1

Jay Timmons

National Association of

837


-------
12/08/11 DRAFT





Manufacturers (NAM)

EPA-HQ-OAR-2009-0234-195 81 - A1

Kent Greenwalt,
Mayor

City of Terrytown

EPA-HQ-OAR-2009-0234-19595

N.A. Bishop

City of Terrytown

EPA-HQ-OAR-2009-0234-19601 -A 1

J. M. Gibney, Jr.

Wahoo Public Utility

EPA-HQ-OAR-2009-0234-19603 - A 1

Steve Rentfrow

Crisp County Power Commission

EPA-HQ-OAR-2009-0234-19622-A2

Adriana Oiler

Nickel Producers Environmental
Reseach Association (NiPERA,
Inc)

EPA-HQ-OAR-2009-0234-19653-A1

Richard Marshall

Spectrum Systems Inc.

EPA-HQ-OAR-2009-0234-19654

Rick Wajda

Indiana Builders Association
(IBA)

EPA-HQ-OAR-2009-0234-19671-A2

Lee A. Casey,
Counsel, Baker
& Hostetler LLP
on behalf of
Institute for
Liberty et al.

Institute for Liberty et al.

EPA-HQ-OAR-2009-0234-19671 -A3

Lee A. Casey,
Counsel, Baker
& Hostetler LLP
on behalf of
Institute for
Liberty et al.

Institute for Liberty et al.

EPA-HQ-OAR-2009-0234- 19677-A1

Michael Ralston

Iowa Association of Business and
Industry (ABI)

EPA-HQ-OAR-2009-0234-19678-A2

Barbara A. Walz

Tri-State Generation and
Transmission Association, Inc.

EPA-HQ-OAR-2009-0234-19679

John Artes

Maryland Department of the
Environment

EPA-HQ-OAR-2009-0234-19741

A. Gwen
Ecklund

West Associates

EPA-HQ-OAR-2009-0234-19742

Andrew J. Such

Michigan Manufacturer's
Association

838


-------