Information on the Various Spray
&EPA Environmental Protection	^ENVIRONMENT	Polyurethane Foam Products

v

Information on the Various Types of Spray Polyurethane Foam Products

SPF Types

Two-component
High-Pressure

Open-Cell (low density, half
lb.)

Closed-Cell (medium density,
2 1b.)

Closed-Cell (high density, 3
lb.)

Two-component
Low-Pressure

One Component
Foam (OCF)

Uses

Larger insulation
applications;

Air sealant in hybrid
insulation installation
with fiberglass or other
insulation material
Roofing applications
(Closed-Cell, high
density,

3 1b.)

Air sealant;

Adhesive;

Smaller insulation
applications;
Weatherization activities

Sealant for filling cracks, holes, gaps,
and crevices:

•	Around windows and doors;

•	For sealing up small gaps (0.5"-
3") in a building to create an
energy efficient building
envelope

This product is inappropriate for
"creative" uses such as science or art
projects and should not be used
around children.

Applicator

Professional Installer

Professional Installer;
Weatherization worker;
Available for do-it-yourself
applicators, but the same
precautions should be taken as
with professional-use. DIY
applicators are often unaware
of inhalation and dermal
hazards and may not have
adequate knowledge, training
and experience to wear
adequate personal protective
equipment.

Professional Installer;
Weatherization worker;
Available for do-it-yourself
applicators but note that the
same precautions should be
taken as with professional-use

Container
Size

55 gallon drum containers

Typically three to five gallons per
container from the system house,
but can be purchased in larger
containers over the internet or in
some retail markets

Available in retail and hardware
stores nationwide in a variety of sizes
ranging from 12 oz. to 24 oz. cans


-------
&EPA Environmental Protection ^^ENVIRONMENT

Information on the Various Spray
Polyurethane Foam Products

Engineering
Controls

Ventilation and containment practices should be considered to control chemical exposures. Work in
"permit-reauired" confined spaces as defined bv OSHA, which mav include work in attics and crawl
spaces, requires entry procedures, including an entry permit, and training for the workers.

OSHA requires a hierarchy of controls, under which employers must first implement engineering controls
where feasible. Consult the safetv data sheet for additional guidance on the use of Personal Protective
Equipment (PPE) and Respiratory Protection when the use of engineering controls are not feasible or
adequate to control exposures. See below for personal protection recommendations for each type of SPF
product.

Personal

Protective

Equipment

•	Supplied Air Respirator;
Loose fitting respirators
are available and do not
require fit testing.
Respirators with a tight
face seal require a fit
test. For more
information, see OSHA's
Respiratory Protection
Standard (29 CFR
1910.134).

•	Eye protection

•	Chemical resistant
clothing;

•	Chemical resistant (e.g.,
nitrile) gloves so that no
skin is exposed

Receive medical surveillance
to ensure applicator is
healthy enough to wear
respirator. Ensure all
equipment is intact upon use
and ensure proper
equipment maintenance.
Vacate all unprotected
workers and building
occupants.

•	Air Purifying Respirator;
Replace cartridges on
appropriate change-out
schedule. Respirators with a
tight face seal require a fit
test. For more information,
see OSHA's Respiratory
Protection Standard (29 CFR
1910.134).

•	Eye protection

•	Chemical resistant clothing;

•	Chemical resistant (e.g.,
nitrile) gloves so that no skin is
exposed

Receive medical surveillance to
ensure applicator is healthy
enough to wear respirator. Ensure
all equipment is intact upon use
and ensure proper equipment
maintenance. Vacate all
unprotected workers and building
occupants.

Read more information about
personal protection when using
two-component low pressure kits.

urn

•	Eye protection

•	Chemical resistant clothing;

•	Chemical resistant (e.g., nitrile)
gloves so that no skin is exposed

Avoid breathing vapors and provide
adequate ventilation. Consult safety
data sheets for additional respiratory
guidance when needed. Ensure all
equipment is intact upon use and
ensure proper equipment
maintenance. Vacate all unprotected
workers and building occupants.

Chemical
Composition

SPF products contain approximately 50 percent Side A and 50 percent Side B. This chemical reaction
generates heat. Side A contains very reactive chemicals known as isocyanates. Side B contains a polyol,
which reacts with isocyanates to make polyurethane, and a mixture of other chemicals, including
catalysts (which help the reaction to occur), flame retardants, blowing agents and surfactants.

Variations in

Chemical

Composition

Open-Cell Blowing Agents:
Carbon Dioxide or Water

Closed-Cell Blowing Agents:
HFC-245fa



Application
Process

Sides A and B are pumped
through heated hoses from
supply tanks into a nozzle
where the two components
react and are spray applied at
elevated temperatures
(>150°F) and pressure (1200

Sides A and B combined at
application site and sprayed on as
a stream or bead. After the foam is
applied, has expanded, and has
cured, it may then be trimmed or
cut, if needed.

OCF components are pre-reacted and
undergo further reaction with
ambient moisture at the time of
application (moisture cured). Applied
as stream or bead. May be trimmed
or sanded.


-------
&EPA Environmental Protection	^ENVIRONMENT

Information on the Various Spray
Polyurethane Foam Products



psij. "Open" cell foam
expands more vigorously
than "closed" cell foam and
should be applied in layers.
See photographs below
illustrating expansion
differences between open-
cell and closed-cell SPF. Foam
can expand up to 120 times
its original volume. After the
foam is applied, has
expanded, and has cured, it
may be trimmed or cut, as
needed; this might especially
be true for the use of "open"
cell foam that may expand
beyond the wall.





Chemical
Exposure
Potential

May be exposed to chemicals:

•	During application

•	After application

•	During heat-generating processes such as drilling, welding, or sanding

•	During fires

Through:

•	Aerosols

•	Vapors

•	Dust that may contain unreacted chemicals

Hazards

•	Asthma

•	Sensitization

•	Lung damage

•	Other respiratory and breathing problems

•	Skin and eye irritation

Re-Entry

Some manufacturers
recommend 24 hours after
application for worker re-
entry without the use of PPE
and for re-occupancy by
residents and other building
occupants, but the
recommended time may vary.
Contact your manufacturer or
supplier for specific guidance.

Some manufacturers recommend
24 hours after application for
worker re-entry without the use of
PPE and for re-occupancy by
residents and other building
occupants, but the recommended
time may vary. Contact your
manufacturer or supplier for
specific guidance.

Some manufacturers estimate that it
can take 8 to 24 hours for one
component foam to cure, but curing
rates can vary.

4^	United States

Environmental Protection
Lb I W^\ Agency


-------