June 2001
NSF 01/11/EPADW395

Environmental Technology
Verification Report

Physical Removal of Giardia cysts and
Cryptosporidium oocysts in Drinking Water

Kinetico Incorporated

SW224 Backwashable Macrolite®

Pressure Filtration System

Prepared by

NSF International

Under a Cooperative Agreement with

&EFA U.S. Environmental Protection Agency

eiVetVeiV


-------
THE ENVIRONMENTAL TECHNOLOGY VERIFICATION

PROGRAM

&EPA

r ixwvjIvvm a

ETV

U.S. Emironmental Protection Agency	NSF International

ETV Joint Verification Statement

TECHNOLOGY TYPE:

BACKWASHABLE DEPTH FILTRATION USED IN
DRINKING WATER TREATMENT SYSTEMS

APPLICATION:

PHYSICAL REMOVAL OF GIARDIA CYSTS AND
CRYPTOSPORIDIUM OOCYSTS IN DRINKING WATER

TECHNOLOGY NAME:

SW224 BACKWASHABLE MACROLITE® PRESSURE
FILTRATION SYSTEM

COMPANY:

KINETICO INCORPORATED



ADDRESS:

10845 KINSMAN ROAD
NEWBURY, OHIO 44065

PHONE: (440)564-9111
FAX: (440) 564-9541

WEB SITE:

www.kinetico.com



EMAIL:

glatimer@kinetico.com



The U.S. Environmental Protection Agency (EPA) has created the Environmental Technology
Verification (ETV) Program to facilitate the deployment of innovative or improved environmental
technologies through performance verification and dissemination of information. The goal of the ETV
program is to further environmental protection by substantially accelerating the acceptance and use of
improved and more cost-effective technologies. ETV seeks to achieve this goal by poviding high
quality, peer reviewed data on technology performance to those involved in the design, distribution,
permitting, purchase, and use of environmental technologies.

ETV works in partnership with recognized standards and testing organizations; stakeholders groups which
consist of buyers, vendor organizations, and permitters; and with the full participation of individual
technology developers. The program evaluates the performance of innovative technologies by developing
test plans that are responsive to the needs of stakeholders, conducting field or laboratory tests (as
appropriate), collecting and analyzing data, and preparing peer reviewed reports. All evaluations are
conducted in accordance with rigorous quality assurance protocols to ensure that data of known and
adequate quality are generated and that the results are defensible.

NSF International (NSF) in cooperation with the EPA operates the Drinking Water Treatment Systems
(DWTS) Pilot, one of 12 technology areas under ETV. The DWTS Pilot recently evaluated the
performance of a backwashable depth filter system used in drinking water treatment system applications.
This verification statement provides a summary of the test results for the Kinetico Incorporated SW224
Backwashable Macrolite® Pressure Filtration System. Cartwright, Olsen and Associates, an NSF-
qualified field testing organization (FTO), performed the verification testing.

01/11/EPADW395	The accompanying notice is an integral part of this verification statement.	June 2001

VS-i


-------
ABSTRACT

Verification testing of the Kinetico Incorporated SW224 Backwashable Macrolite® Pressure Filtration
System was conducted for 3 2'/days between March 24 and May 1, 2000, and three protozoan challenges
were performed between April 24 and 27, 2000. Between March 24 and May 1, 2000, raw water
characteristics were: average pH 8.6, temperature 10.3°C, turbidity 0.77 Nephlometric Turbidity Units
(NTU), and total alkalinity 53 mg/L. Average calculated flow rate over the test period was 27.98 gpm.
The filter runs averaged 11.7 hours, with an average of 21,075 gallons per filter run. The average effluent
turbidity was 0.23 NTU. During the protozoan challenges the raw water characteristics were: average pH
9.2, temperature 11.4°C, turbidity 0.6 NTU, and total alkalinity in the range of 50-52 mg/L. The average
effluent turbidity was 0.2 NTU. The system demonstrated 1.6 to 3.7 logio reductions of Giardia lamblia
(G. lamblia) cysts and 0 to 0.8 logio reductions of Cryptosporidium parvum (C. parvum) oocysts. These
results were obtained at an average flow rate of 28.4 gpm. Analysis of filter effluent samples suggest G.
lamblia cysts and C. parvum oocysts were released from the filter bed as a result of the stop/start
sequence.

TECHNOLOGY DESCRIPTION

The Kinetico SW224 is designed expressly for small system applications. Media vessels (filters)
measured 24" in diameter and 72" in height and are offered in fiberglass or steel construction. Fiberglass
reinforced polyethylene media tanks, pressure rated to 100 psi, were used for this study. The liquid
volume capacity of each media vessel is 119 gallons without media. Filter media bed depth was 36".

Two identical filters are used within the Kinetico SW224 Filter System. Filters are identified as "T1A"
and "T2A" and operating alternately. The filter media is Macrolite®, a synthetic ceramic, filter media.

Macrolite® of the 70/80 mesh size has a bulk density of 0.96 grams/cubic centimeter (g/cc). The specific
gravity (as measured by American Society for Testing and Materials (ASTM) D2840) is 2.23 g/cc. The
collapse strength for the media of this size has not been measured, however, for a larger sphere (30/50
mesh) the collapse strength (as measured by ASTM D3102) is a nominal 7,000 psi for 10% and nominal
8,000 psi for 20% collapse.

The uniformity of the Macrolite® 70/80 mesh media was analyzed in accordance with AWWA Standard
B100-96 by Bowser-Morner, Inc in December, 1997. The results of this analysis are summarized below:

Uniformity of the Macrolite® 70/80 Mesh Media (AWWA Standard B100-96)

Sieve Size, USA Std.

Nominal, mm

Effective, mm

Percent passing

#45

0.355

0.360

100.0

#50

0.300

0.307

99.9

#60

0.250

0.249

79.8

#70

0.212

0.212

28.9

#80

0.180

0.180

7.2

#100

0.150

0.150

0.4

Effective Size:	0.19 mm

Uniformity Coefficient: 1.2

In addition, a June 1998 Kinetico internal laboratory analysis of 70 mesh media (lot # 352) employing a
mercury/penetrometer Micromeritics Autopore II 9220 instrument produced the following results:

01/11/EPADW395	The accompanying notice is an integral part of this verification statement.	June 2001

VS-ii


-------
Uniformity of the Macrolite® 70/80 Mesh Media (Micromeritics Autopore)

Total intrusion volume	0.2098 mL/g

Total pore area	0.18 sq-m/g

Median pore diameter by volume 53.7990 (im
Median pore diameter by area	52.5351 (im

Median pore diameter by 4V/A 46.5685 (im

The flow of water through the system is controlled with hydro pneumatically actuated valves mounted on
face piping constructed of Schedule 80 PVC. Automatic valves are actuated via a programmable logic
controller. The valves also have handles for manual activation.

Accessories and instrumentation included with the Kinetico SW224 System included flow rate and
pressure sensors and monitors, on-line turbidimeters, pressure gauges, backwash pumps and an electrical
enclosure containing a programmable logic controller and a touch screen monitor. The equipment also
contained data transfer connections available for remote monitoring.

The filters are shipped skid mounted and absent of media. Filter media was loaded on site. The total
weight of the system, without media, is approximately 1,700 pounds. Spatial size of the Kinetico SW224
Filter System was 4'l1/4" W x 9'6 %L x 87 W" H.

VERIFICATION TESTING DESCRIPTION

Test Site

The host site for this demonstration was the University of Minnesota St. Anthony Falls Hydraulic
Laboratory (SAFHL), which has direct access to untreated and treated Mississippi river water. SAFHL is
located on the Mississippi River at Third Avenue S.E., Minneapolis, Minnesota 55414. Influent to the
Kinetico SW224 system was a blend of river water and treated water from the Minneapolis Water Works.

Methods and Procedures

The verification test was divided into tasks that evaluated the system's treatment performance,
specifically its ability to physically remove G. lamblia cysts and C. parvum oocysts from the feed water,
and documented the system's operational parameters.

Water quality parameters that were monitored during the verification test included: pH, temperature,
turbidity, particle counts, free chlorine residual, total alkalinity, total hardness, total organic carbon
(TOC), ultraviolet absorbance (UVA) at 254 nanometer (nm), true color, ron, manganese, algae, total
coliform, and E. coli. Laboratory analyses were performed in accordance with the procedures and
protocols established in Standard Methods for the Examination of Water and Wastewater, 19th Edition
(SM) or EPA-approved methods.

Three seeding challenges employing G. lamblia cysts and C. parvum oocysts occurred between April 24
and 27, 2000. The protozoan analyses (identification and enumeration) were conducted using EPA
Method 1623. During seeding studies, sodium thiosulfate was injected into the blended feedwater stream
in place of chlorine to reduce chlorine residuals within the filter influent water previous to the point of
protozoan injection. A mixture of cysts and oocysts was added to the raw water through an injection
probe at the intake of the static mixer. The analyses of the influent samples indicated that the mixture
contained between 660,000 and 3,800,000 G. lamblia cysts per liter, and between 2,800,000 and
17,000,000 C. parvum oocysts per liter during the three seeding challenges. During the seedings, 10 liters
were collected from a side stream at a rate of 170 milliliters per minute over a one-hour period (equivalent
to 20 bed volumes) and filtered through a Gelman capsule filter for enumeration. The 10-liter samples
filtered through a Gelman capsule filter were evaluated in accordance with the procedures indicated in
EPA Method 1623. Filter influent and effluent grab samples were taken at initial start up, at the mid-

01/1 1/EPADW395	The accompanying notice is an integral part of this verification statement.	June 2001

VS-iii


-------
point of the filter run and at the end of the filter run, just prior to terminal headloss. These seedings allow
determination of filter efficacy at several points in the filter cycle. In addition to these challenges, the
flow of water through the Kinetico SW224 Filter System was discontinued soon after the midpoint
(oo)cyst seeding study during each of the three challenge filter runs. Filter effluent water was directed to
an (oo)cyst collection filter over a period of 60 minutes beginning immediately after the resumption of
flow though the filter and analyzed for G. lamblia cysts and C. parvum oocysts. This sequence was
termed a "stop/start event".

VERIFICATION OF PERFORMANCE

Source Water

Between March 24 and May 1, 2000, raw water characteristics were: average pH 8.6, temperature 10.3°C,
turbidity 0.77 NTU, and total alkalinity 53 mg/L. During the protozoan challenges the raw water
characteristics were: average pH 9.2, temperature 11.4°C, turbidity 0.6 NTU, and total alkalinity in the
range of 50-52 mg/L.

Operation and Maintenance

The length per filter run varied over the test period, and although the system was not monitored 24 hours
per day, a representative filter run at the beginning of the test period was 19.94 hours in length, in the
middle of the test period was 17.95 hours and at the end of the test period was 6.50 hours. Recorded total
filter run volumes ranged from 5,163 gallons (4/28/00) to 44,347 gallons (3/26/00) per filter run. The
filter runs averaged 11.7 hours, with an average of 21,075 gallons per filter run. Continuous monitoring
was not required and the technician was not on site during all filter runs; therefore data averages are
representative of runs that occurred during technician monitoring. Average calculated flow rate over the
test period was 27.98 gpm. The following table is representative of data compiled from two runs selected
for the beginning, middle and end run cycles to replicate the data during that time frame.

Average Operating Conditions (March 24 through May 1, 2000)













Backwash







Filter Run

Beginning Flow

Ending Flow

Change in



Rinse

Backwash

Backwash

Test Period

Time

Rate

Rate

Pressure

Gallons

Volume

Volume

Flow Rate

Time Frame

(hrs)

(gpm)

(gpm)

(psi)

Filtered

(Gallons)

(Gallons)

(gpm)

Beginning

19.94

29.70

28.47

13

34,037

146

287

16

Middle

17.95

30.24

26.52

12

30,847

183

285

16.5

End

6.50

30.15

27.27

11

10,237

157

339

16.8

The Kinetico SW224 Filter System is a packaged water filtration plant designed to provide a continuous
process flow and automated to require minimal operator intervention. To support this design two filters
are included within the Kinetico SW224 package. When one filter is in operation, the alternate filter is
off-line. Filter run time is determined by one of the following events as monitored by the water treatment
plant's PLC with timers and sensors/meters installed within the appropriate process stream: Head loss;
Turbidity breakthrough; and Time. These values were initially set at 22 psi, 0.5 NTU and 24 hours,
respectively. When one of these set-point values is exceeded, the filter run is discontinued and the
alternate filter is rinsed and put on-line with minimal interruption in flow. During 50 filter runs that were
observed in their entirety, it was noted that the equipment could virtually operate without operator
interface.

The only recurring problem with the operation of the Kinetico SW224 filter system involved the on-line
turbidimeters supplied with the equipment which required frequent cleaning and verification of
calibration.

01/11/EPADW395	The accompanying notice is an integral part of this verification statement.	June 2001

VS-iv


-------
The O&M manual provided by the manufacturer primarily defined installation, operation and
maintenance requirements for Kinetico SW224 Filter System. The manual provided information
pertaining to basic installation, start-up, and operational process. A process schematic, trouble shooting
guide, and associated O&M manuals for components used within the Kinetico SW224 Filter System were
also provided. The O&M manual was reviewed for completeness and used during equipment installation,
start-up, system operation, and trouble-shooting. It was found the manual provides adequate instruction
for tasks required to perform these functions over the period of operation of the ETV test period. In cases
where the operator desired to confirm his interpretation of instructions within the O&M manual,
Kinetico's customer support department proved to be responsive.

Protozoan Contaminant Removal

The system demonstrated 1.6 to 3.7 logio reductions of G. lamblia cysts and 0 to 0.8 logio reductions of C.
parvum oocysts. These results were obtained at an average flow rate of 28.4 gpm. Analysis of filter
effluent samples suggest G. lamblia cysts and C. parvum oocysts were released from the filter bed as a
result of the stop/start event. The number of (oo)cysts detected in the filter effluent during the stop/start
event were considerably lower than the number detected during the midpoint seeding challenges and may
be further reduced by lengthening the filter-to-waste.

Finished Water Quality

The average effluent turbidity during the 3214day verification testing period was 0.23 NTU. The
average effluent turbidity during the protozoan challenges was 0.17 NTU. A summary of the influent and
effluent water quality information for the verification period of March 24 through May 1, 2000 is
presented in the following table.

	Influent/Effluent Water Quality (March 24-May 1, 2000)	

Parameter

# of Samples

Average

Minimum

Maximum

Total Alkalinity (mg/L)

6/6

53/54

47/49

62/63

Total Hardness (mg/L)

6/6

80/78

74/73

88/87

TOC (mg/L)

6/6

6.4/6.4

6.1/6.1

6.5/6.6

UVA254 (cm1)

6/6

0.098/0.098

0.082/0.086

0.108/0.106

Iron (mg/L)

6/6

<0.1/0.1

<0.1/0.1

<0.1/0.1

Manganese (mg/L)

6/6

0.01/0.01

0.01/0.01

0.02/0.01

pH

34

8.6/NA

7.2/NA

9.5/NA

Temperature (C)

34

10.3/NA

7.1/NA

15.4/NA

Free Chlorine (ppm)

11

0.78/NA

0.27/NA

1.48/NA

Notes: All calculations involving results with below PQL values used 1/2 the PQL in the calculation.
Effluent samples were not analyzed for pH, temperature or free chlorine.

Power Consumption

During the 32l4day verification testing period the Kinetico SW224 Filter System unit used 147 kWh for
1,307,850 gallons of water filtered. This equates to 8,897 gallons of filtered water per kWh.

Original Signed by
Frank Princiotta for
E. Timothy Oppelt

07/25/01

Original Signed by
Gordon Bellen

07/26/01

E. Timothy Oppelt	Date

Director

National Risk Management Research Laboratory

Office of Research and Development

United States Environmental Protection Agency

Gordon Bellen
Vice President
Federal Programs
NSF International

Date

01/11/EPADW395	The accompanying notice is an integral part of this verification statement.	June 2001

VS-v


-------
NOTICE: Verifications are based on an evaluation of technology performance under specific,
predetermined criteria and the appropriate quality assurance procedures. EPA and NSF make no
expressed or implied warranties as to the performance of the technology and do not certify that a
technology will always operate as verified. The end user is solely responsible for complying with
any and all applicable federal, state, and local requirements. Mention of corporate names, trade
names, or commercial products does not constitute endorsement or recommendation for use of
specific products. This report is not a NSF Certification of the specific product mentioned herein.

Availability of Supporting Documents

Copies of the ETV Protocol for Equipment Verification Testing for Physical Removal of
Microbiological and Particulate Contaminants dated May 14, 1999, the Verification
Statement, and the Verification Report (NSF Report # 01/11/EPADW395) are available
from the following sources:

(NOTE: Appendices are not included in the Verification Report. Appendices are
available from NSF upon request.)

1.	Drinking Water Treatment Systems ETV Pilot Manager (order hard copy)
NSF International

P.O. Box 130140

Ann Arbor, Michigan 48113-0140

2.	NSF web site: http://www.nsf.org/etv (electronic copy)

3.	EPA web site: http://www.epa.gov/etv (electronic copy)

01/11/EPADW395	The accompanying notice is an integral part of this verification statement.	June 2001

VS-vi


-------
Environmental Technology Verification Report

Removal of
Giardia and Cryptosporidium
in Drinking Water

Kinetico SW224 Backwashable Pressure Filtration

System

Prepared for:

NSF International
Ann Arbor, Michigan 48105

Prepared by
Cartwright, Olsen and Associates, LLC

Under a cooperative agreement with the U.S. Environmental Protection Agency

Jeffrey Q. Adams, Project Officer
National Risk Management Research Laboratory
U.S. Environmental Protection Agency
Cincinnati, Ohio 45268


-------
Notice

The U.S. Environmental Protection Agency (EPA) through its Office of Research and Development has
financially supported and collaborated with NSF International (NSF) under Cooperative Agreement
No. CR 824815. This verification effort was supported by Drinking Water Treatment Systems Pilot
operating under the Environmental Technology Verification (ETV) Program. This document has been
peer reviewed and reviewed by NSF and EPA and recommended for public release.

11


-------
Foreword

The following is the final report on an Environmental Technology Verification (ETV) test performed for
NSF International (NSF) and the United States Environmental Protection Agency (EPA) by Cartwright,
Olsen & Associates, LLC, (COA) in cooperation with Kinetico, Inc. The test was conducted during
March and April of 2000 at the University of Minnesota St. Anthony Falls Hydraulic Laboratory.

Throughout its history, the EPA has evaluated the effectiveness of innovative technologies to protect
human health and the environment. A new EPA program, the Environmental Technology Verification
Program (ETV) has been instituted to verify the performance of innovative technical solutions to
environmental pollution or human health threats. ETV was created to substantially accelerate the
entrance of new environmental technologies into the domestic and international marketplace. Verifiable,
high quality data on the performance of new technologies are made available to regulators, developers,
consulting engineers, and those in the public health and environmental protection industries. This
encourages more rapid availability of approaches to better protect the environment.

The EPA has partnered with NSF, an independent, not-for-profit testing and certification organization
dedicated to public health, safety and protection of the environment, to verify performance of small
package drinking water systems that serve small communities under the Drinking Water Treatment
Systems (DWTS) ETV Pilot Project. A goal of verification testing is to enhance and facilitate the
acceptance of small package drinking water treatment equipment by state drinking water regulatory
officials and consulting engineers while reducing the need for testing of equipment at each location where
the equipment's use is contemplated. NSF will meet this goal by working with manufacturers and NSF-
qualified Field Testing Organizations (FTO) to conduct verification testing under the approved
protocols.

The ETV DWTS is being conducted by NSF with participation of manufacturers, under the sponsorship
of the EPA Office of Research and Development, National Risk Management Research Laboratory,
Water Supply and Water Resources Division, Cincinnati, Ohio. It is important to note that verification
of the equipment does not mean that the equipment is "certified" by NSF or "accepted" by EPA.
Rather, it recognizes that the performance of the equipment has been determined and verified by these
organizations for those conditions tested by the FTO.

111


-------
Table of Contents

Section	Page

Verification Statement	VS-i

Title Page	i

Notice	ii

Foreword	iii

Table of Contents	iv

Abbreviations and Acronyms	ix

Definitions	xi

Acknowledgments	xii

Chapter 1: Introduction.	1

1.1	ETV Purpose and Program Operation	1

1.2	Testing Participants and Responsibilities	1

1.2.1	NSF International	2

1.2.2	Field Testing Organization	2

1.2.3	Manufacturer	3

1.2.4	Analytical Laboratories	3

1.2.5	University of Minnesota St. Anthony Falls Hydraulic Laboratory	4

1.2.6	U. S. Environmental Protection Agency	5

1.3	Verification Testing Site	5

1.3.1	Source Water	5

1.3.2	Pilot Effluent Discharge	7

Chapter 2 Equipment Description and Operating Processes	8

2.1	Historical Background	8

2.2	Equipment Description	9

2.3	Operator Licensing Requirements	15

Chapter 3 Methods and Procedures	16

3.1	Experimental Design	16

3.1.1 Objectives	16

3.1.1.1	Evaluation of Stated Equipment Capabilities	16

3.1.1.2	Evaluation of Equipment Performance Relative To Water Quality Regulations	16

3.1.1.3	Evaluation of Operational and Maintenance Requirements	16

3.1.1.4	Evaluation of Equipment Characteristics	17

3.2	Verification Testing Schedule	17

3.3	Initial Operations	17

3.3.1	Characterization of Influent Water	18

3.3.2	Initial Test Runs	19

3.4	Verification Task Procedures	20

3.4.1 Task 1 - Verification Testing Runs and Routine Equipment Operation	20

iv


-------
Table of Contents, continued

Section	Page

3.4.2	Task 2 - Influent and Effluent Water Quality Characterization	21

3.4.3	Task 3 - Documentation of Operating Conditions and Treatment Equipment
Performance	22

3.4.4	Task 4 - Microbiological Contaminant Removal Testing	23

3.4.4.1	Preparation of Microbial Doses	24

3.4.4.2	Analytical Schedule	24

3.4.4.3	Data Evaluation	26

3.4.4.4	Evaluation Criteria	26

3.5	Recording Data	26

3.5.1	Objectives	27

3.5.2	Procedures	27

3.5.2.1	Logbooks	27

3.5.2.2	Photographs	27

3.5.2.3	Chain of Custody	28

3.5.2.4	Inline Measurements	28

3.5.2.5	Spreadsheets	28

3.6	Calculation of Data Quality Indicators	28

3.6.1	Representativeness	28

3.6.2	Statistical Uncertainty	29

3.6.3	Accuracy	29

3.6.4	Precision	30

3.7	Equipment	30

3.8	Health and Safety Measures	31

3.9	QA/QC Procedures	31

3.9.1	QA/QC Verifications	32

3.9.2	On-Site Analytical Methods	32

3.9.2.1	pH	32

3.9.2.2	Temperature	33

3.9.2.3	Turbidity	33

3.9.2.4	Particle Counting	33

3.9.2.5	Particle Free Water	35

3.9.3	Off-Site Analysis For Chemical and Biological Samples	35

3.9.3.1	Organic Parameters: Total Organic Carbon and UV254 Absorbance	35

3.9.3.2	Microbial Samples: Coliform and Algae	35

3.9.3.3	Inorganic Samples	36

3.9.3.4	True Color	36

Chapter 4 Results and Discussion	37

4.1	Introduction	37

4.2	Initial Operations Period Results	37

v


-------
Table of Contents, continued

Section	Page

4.2.1	Characterization of Influent Water	37

4.2.2	Initial Test Runs	38

4.2.3	Hydraulic Flow Tracer Study	39

4.3	Verification Testing Results and Discussions	41

4.3.1	Task 1 - Verification Testing Runs And Routine Equipment Operation	41

4.3.2	Task 2 - Influent and Effluent Water Quality Characterization	42

4.3.3	Task 3 - Documentation of Operating Conditions and Treatment Equipment
Performance	46

4.3.4	Task 4 - Microbiological Contaminant Removal Testing	48

4.3.4.1	Water Characteristics	48

4.3.4.2	Operational and Analytical Data Tables	49

4.3.4.3	Discussion of Results	51

4.3.4.4	Stop/Start Event Evaluation	53

4.4	Equipment Characteristics Results	57

4.4.1	Qualitative F actors	57

4.4.1.1	Susceptibility to Changes in Environmental Conditions	57

4.4.1.2	Operational Requirements	57

4.4.1.3	Evaluation of O&M Manual	58

4.4.1.4	Safety	58

4.4.2	Quantitative F actors	58

4.4.2.1 Power Requirements	58

4.5	QA/QC Results	58

4.5.1	Data Correctness	59

4.5.1.1	Representativeness	59

4.5.1.2	Statistical Uncertainty	59

4.5.1.3	Accuracy	59

4.5.1.4	Precision	60

4.5.2	Daily QA/QC Results	60

4.5.3	One- Time QA/QC Verification Results	61

4.5.4	Results Of QA/QC Verifications At The Start Of Each Testing Period	61

4.5.5	Analytical Laboratory QA/QC	66

Chapter 5 References	68

Tables	Page

Table 1-1. Influent Water Quality (March 24 - May 1, 2000)	7

Table 2-1. Uniformity of Macrolite® 70/80 Mesh Media (AWWA Standard B100-96)	11

Table 2-2. Uniformity of Macrolite® 70/80 Mesh Media (Micromeritics Autopore 119220)	11

Table 3-1. Analytical Data Collection Schedule	22

Table 3-2. Operating Data	23

vi


-------
Table of Contents, continued

Tables	Page

Table 4-1. Influent and Effluent Water On-Line Turbidity (March 24 - May 1, 2000)	42

Table 4-2. Influent Water Samples Characteristics (March 24 - May 1, 2000)	44

Table 4-3. Effluent Water Samples Characteristics (March 24 - May 1, 2000)	45

Table 4-4. Summary of Filter Influent and Effluent Particle Counts of >_3 |am,  3|im, < 7|im Sized

Particles Indigenous to the Source Water	46

Figure 4-5. 3-7 |j,m Particle Count Logio Removal and Turbidity Measurement During Challenge #1..50
Figure 4-6. 3-7 |j,m Particle Count Logio Removal and Turbidity Measurement During Challenge #2..50
Figure 4-7. 3-7 |j,m Particle Count Logio Removal and Turbidity Measurement During Challenge #3. .51

Figure 4-8. Effluent 3-7 |j,m Particle Count Stop/Start During Protozoa Challenge #1	55

Figure 4-9. Effluent 3-7 |j,m Particle Count Stop/Start During Protozoa Challenge #2	55

Figure 4-10. Effluent 3-7 |j,m Particle Count Stop/Start During Protozoa Challenge #3	56

Figure 4-11. Verification of 3 |j,m Influent Particles	62

Figure 4-12. Verification of 10 |j,m Influent Particles	62

Figure 4-13.Verification of 15 |j,m Influent Particles	63

Figure 4-14. Verification of Mix of 3, 10 & 15 |j,m Influent Particles	63

Figure 4-15. Verification of 3 |j,m Effluent Particles	64

Figure 4-16. Verification of 10 |j,m Effluent Particles	64

Figure 4-17. Verification of 15 |j,m Effluent Particles	65

Figure 4-18. Verification of 3, 10 & 15 |j,m Effluent Particles	65

Photos

Photo 1. Front view of the Kinetico SW224 Filter System at the University of Minnesota	14

Photo 2. Side view of the Kinetico SW224 Filter System at the University of Minnesota	14

vii


-------
Table of Contents, continued

Appendices

A.

Laboratory Approval Statements

B.

Manufacturer's Operation and Maintenance Manual

C.

Data Spreadsheets

D.

Data Logbook

E.

Laboratory Chain of Custody Forms

F.

Laboratory Reports

G.

QA/QC Documentation

viii


-------
Abbreviations and Acronyms

APHA	American Public Health Association

ASTM	American Society for Testing and Materials

AWWA	American Water Works Association

°C	Degrees Celsius

cc	Cubic centimeters

C. parvum	Cryptosporidium parvum

cfh	Cubic feet per hour

cfrn	Cubic feet per minute

CFU	Colony Forming Units

CO A	Cartwright, Olsen, and Associates, LLC

DI	Deionized (demineralized) water

DWTS	Drinking Water Treatment Systems

E.coli	Escherichia coli

EPA	U.S. Environmental Protection Agency

ESWTR	Enhanced Surface Water Treatment Rule

ETV	Environmental Technology Verification

°F	Degrees Fahrenheit

F OD	Field Operations Document

FTO	Field Testing Organization

G. lamblia	Giardia Lamblia

G. muris	Giardia Muris

gallons	Gallons are expressed as US gallons, 1 gal = 3.785 liters

gpm	Gallons per minute

HP	Horse power

ICR	Information Collection Rule

IMS	Immunomagnetic separation

Kinetico	Kinetico Incorporated

kW	Kilowatt

Log	Logarithm to the base 10

|j,m	Micron

mgd	Million gallons per day

mg/L	Milligram per liter

mL	Milliliter

MPA	Microscopic Particulate Analysis

MWW	Minneapoli s W ater W orks

NAWQA	National Water-Quality Assessment

NIST	National Institute of Standards and Technology

NSF	NSF International, formally known as National Sanitation Foundation

NTU	Nephelometric Turbidity Unit

(oo)cyst	Conventionally used to refer to either cysts or oocysts

O&M	Operations and Maintenance

IX


-------
PFW
pH

PLC

PQL

psi

Psig

PVC

QA/QC

SAFHL

SM

SWTR

TCU

IDS

TOC

TSS

Ten State's Standards

USGS

UV

WEF

Particle Free Water

A measure of the degree of the acidity or the dkalinity of a solution as

measured on a scale of 0 to 14.

Programmable Logic Computer

Practical Quantification Limit

Pounds per square inch

Pounds per square inch gauge

Polyvinyl chloride

Quality Assurance/Quality Control

St. Anthony Falls Laboratory of the University of Minnesota

Standard Methods for the Examination of Water and Wastewater, 19th

Edition

Surface Water Treatment Rule
Total Color Units
Total dissolved solids
Total Organic Carbon
Total Suspended Solids

Great Lakes-Upper Mississippi River Board of State Public Health and
Environmental Managers, Recommended Standards for Water Works
U.S. Geological Survey
Ultraviolet

Water Environment Federation

x


-------
Definitions

Backwashable Depth Filter

A granulated media filter intended to filter uncoagulated or coagulated water and designed to be
backwashed when either turbidity breakthrough occurs or terminal headloss is reached.

Colloid

In water treatment the term refers to charged, suspended particles such as clays, metal salts and
microbes that coagulate into larger agglomerates in water, thus allowing filtration.

Conventional filtration treatment

A treatment train involving coagulation, flocculation, sedimentation, and filtration.

Direct filtration

A process involving coagulation and filtration, but excluding the sedimentation step.

Filtration

A process for removing particulate matter from water by passage through porous media.

Granular Media Filter

A deep bed filter containing granular media used to filter water. These filters rely on straining particles
out of the water, or by attachment of the particles to the media.

Sedimentation

Separation of solids prior to filtration by gravity settling or through other hydraulic means.

Ten State's Standards

A compilation of accepted civil engineering water treatment plant design standards, published as "Great
Lakes-Upper Mississippi River Board of State Public Health and Environmental Managers,
Recommended Standards for Water Works" (1992).

XI


-------
Acknowledgments

The Field Testing Organization, Cartwright, Olsen & Associates (COA), was responsible for all
elements in the testing sequence, including collection of samples, calibration and verification of
instruments, data collection and analysis, data management, data interpretation and the preparation of
this report.

Cartwright, Olsen & Associates, LLC

19406 East Bethel Blvd.

Cedar, Minnesota 55011

Phone: (763)434-1300

Fax: (763) 434-8450

E-mail: p.olsen@ix.netcom.com

Contact Person: Philip C. Olsen

Challenge seeding and elution of filter cartridges for concentration of Cryptosporidium parvum (C.
parvum) oocysts were conducted by:

Debra Huffman Env. Consulting

6762 Millstone Drive

New Port Richey, Florida 34655

Phone: (727) 553-3946

Fax: (727) 893-1189

Contact Person: Debra Huffman, Ph.D.

E-mail: dhuffinan@marine.usf.edu

The laboratory that conducted the protozoa analytical work of this study was:

BioVir Laboratories, Inc.

685 Stone Road

Benicia, California 94510

Phone: (707) 747-5906 or (800) 442-7342

Fax (707)747-1751

Contact Person: Richard E. Danielson, Ph.D., Quality Assurance Officer, Principal
Analyst/ Supervi sor

The laboratory that conducted the remaining analytical work of this study was:

Spectrum Labs Inc.

301 West County Road E2
St. Paul, Minnesota 55112
Phone: (651)633-0101
Fax: (651)633-1402

Xll


-------
Contact Person: Gerard Herro, Laboratory Manager
E-mail: gherro@spectrum-labs.com

The Manufacturer of the Equipment was:

Kinetico Incorporated

10845 Kinsman Road

Newbury, Ohio 44065

Phone: (440) 564-9111 or (800) 432-1166

Fax: (440)564-9541

E-mail: glatimer@kinetico.com

Contact Person: Glen Latimer, Operations Manager

CO A wishes to thank NSF International, especially Mr. Bruce Bartley, Project Manger, and Carol
Becker and Kristie Wilhelm, Environmental Engineers for providing guidance and program management.

Glen Latimer, Manager Municipal Sales, Chip Fatheringham, Coordinator-Pilot Operations, Sam
Mason, Research Scientist, Skip Wolf and Jeff Hoover, Kinetico Incorporated are to be commended
for providing the treatment system and the excellent technical and product expertise.

The University of Minnesota St. Anthony Falls Hydraulic Laboratory staffs including Scott Morgan,
M.S., P.E. Research Fellow, Jeff Marr, Research Fellow, Julie A. Tank, Jr. Engineer, and Jason
McDonald, Jr. Engineer, are to be recognized for their assistance during the pilot setup, and tear down
as well as assistance during the pilot operation.

COA also wishes to thank the Minnesota Department of Health, Drinking Water Protection for their
invaluable analytical and operational assistance, especially Gerald Smith, P.E., Public Health Engineer,
and Anita C. Anderson, Public Health Engineer.

xrn


-------

-------
Chapter 1
Introduction

1.1	ETV Purpose and Program Operation

The U.S. Environmental Protection Agency (EPA) has created the Environmental Technology
Verification (ETV) Program to facilitate the deployment of innovative or improved environmental
technologies through performance verification and dissemination of information. The goal of the ETV
program is to further environmental protection by substantially accelerating the acceptance and use of
improved and more cost-effective technologies. ETV seeks to achieve this goal by providing high
quality, peer le vie wed data on technology performance to those involved in the design, distribution,
permitting, purchase, and use of environmental technologies.

ETV works in partnership with recognized standards and testing organizations; stakeholders groups
which consist of buyers, vendor organizations, and permitters; and with the full participation of individual
technology developers. The program evaluates the performance of innovative technologies by
developing test plans that are responsive to the needs of stakeholders, conducting field or laboratory (as
appropriate) testing, collecting and analyzing data, and preparing peer reviewed reports. All evaluations
are conducted in accordance with rigorous quality assurance protocols to ensure that data of known
and adequate quality are generated and that the results are defensible.

NSF International (NSF) in cooperation with the EPA operates the Drinking Water Treatment Systems
(DWTS) project, one of 12 technology areas under ETV. The DWTS project evaluated the
performance Kinetico, Inc. (Kinetico) SW224 Backwashable Macrolite® Pressure Filtration System
(KI SW224 Filter System), which is a backwashable depth filter used in package drinking water
treatment system applications. The testing of the system was conducted to verify the system's capability
of removing Cryptosporidium parvum (C. parvum) and Giardia lamblia (G. lamblia). This
document provides the verification test results for the Kinetico SW224 Filter System.

1.2	Testing Participants and Responsibilities

The ETV testing of the Kinetico SW224 Filter System was a cooperative effort between the following
participants:

NSF International

Cartwright, 01 sen & Associates, LLC
Kinetico, Incorporated
Debra Huffman Env. Consulting
BioVir Laboratories, Inc.,

Spectrum Labs, Inc.

University of Minnesota St. Anthony Falls Hydraulic Laboratory
U.S. Environmental Protection Agency

1


-------
The following is a brief description of each ETV participant and their roles and responsibilities.

1.2.1	NSF International

NSF is a not-for-profit standards and certification organization dedicated to public health safety and the
protection of the environment. Founded in 1946 and located in Ann Arbor, Michigan, NSF has been
instrumental in the development of consensus standards for the protection of public health and the
environment. NSF also provides testing and certification services to ensure that products bearing the
NSF Name, Logo and/or Mark meet those standards. The EPA partnered with the NSF to verify the
performance of drinking water treatment systems through the EPA's ETV Program.

NSF provided technical and primarily quality oversight of the verification testing. An audit of the field
analytical and data gathering and recording procedures was conducted. NSF also reviewed the Field
Operations Document (FOD) to assure its conformance with pertinent ETV generic protocol and test
plan. NSF also conducted a review of this report and coordinated the EPA and technical reviews of
this report.

Contact Information:

NSF International

789 N. Dixboro Rd.

Ann Arbor, Michigan 48105

Phone: 734-769-8010

Fax: 734-769-0109

Contact: Bruce Bartley, Project Manager

E-mail: bartley@nsf.org

1.2.2	Field Testing Organization

Cartwright, Olsen & Associates, a Limited Liability Company, conducted the verification testing of
Kinetico SW224 Filter System. COA is a NSF-qualified Field Testing Organization (FTO) for the
DWTS ETV pilot project.

The FTO was responsible for conducting the verification testing for 30 calendar days. The FTO
provided all needed logistical support, established a communications network, and scheduled and
coordinated activities of all participants. The FTO was responsible for ensuring that the testing location
and influent water conditions were such that the verification testing could meet its stated objectives. The
FTO prepared the FOD, oversaw the pilot testing, managed, evaluated, interpreted and reported on the
data generated by the testing, as well as evaluated and reported on the performance of the technology.

FTO associates and University of Minnesota staff conducted the onsite analyses and data recording
during the testing. Oversight of the daily tests was provided by the FTO's Project Manager.

2


-------
Contact Information:

Cartwright, 01 sen & Associates, LLC
19406 East Bethel Blvd.

Cedar, Minnesota 55011
Phone: (763)434-1300
Fax: (763) 434-8450

Contact Person: Philip C. Olsen, Project Manager
E-mail: p.olsen@ix.netcom.com

1.2.3	Manufacturer

The treatment system is manufactured by Kinetico, a manufacturer of non-electric, demand operated
water processing systems. Kinetico has grown rapidly into one of the largest manufactures of water
treatment systems worldwide. Kinetico is headquartered in Newbury, Ohio

Kinetico was responsible for supplying a field-ready Kinetico SW224 Filter System equipped with all
necessary components including treatment equipment, instrumentation and controls and an operations
and maintenance manual. Kinetico was responsible for providing logistical and technical support as
needed as well as providing technical assistance to the FTO during operation and monitoring of the
equipment undergoing field verification testing.

Contact Information:

Kinetico, Incorporated
10845 Kinsman Road
Newbury, Ohio 44065
Phone: (440) 564-9111
Fax: (440)564-9541
Contact Person: Glen Latimer
E-mail: glatimer@kinetico.com

1.2.4	Analytical Laboratories

Challenge seeding and recovery of G. lamblia and C. parvum (oo)cysts:

Contact Information:

Debra Huffman Env. Consulting

6762 Millstone Drive

New Port Richey, Florida 34655

Phone: (727) 553-3946

Fax: (727) 893-1189

Contact: Debra Huffman, Ph.D.

E-mail: dhuffinan@marine.usf.edu

3


-------
BioVir Laboratories, Inc. of Benicia, California, performed microbiological laboratory work. BioVir's
laboratory is certified by the California Department of Health Services. Additionally, the laboratory has
received Protozoa Laboratory Approval from the EPA under the Information Collection Rule (ICR)
Program. A copy of the Laboratory Approval Statements is attached in Appendix A.

Contact Information:

BioVir Laboratories, Inc.

685 Stone Road
Benicia, California 94510
Phone: (707) 747-5906
Fax: (707) 747-1751

Contact: Richard E. Danielson, Ph.D., Quality Assurance Officer, Principal Analyst/Supervisor

Tests for Escherichia coli (E.coli), Coliform bacteria and off-site non-microbial work were performed
by Spectrum Labs, Inc. Spectrum's laboratory provided analytical services for Total Alkalinity, Total
Hardness, Total Organic Carbon (TOC), Ultraviolet (UV)254 Absorbance, True Color, Total Coliform,
Algae, (number and species), Iron and Manganese.

Contact Information:

Spectrum Labs Inc.

301 West County Road E2
St. Paul, Minnesota 55112
Phone: (651)633-0101
Fax: (651)633-1402

Contact: Gerard Herro, Laboratory Manager
E-mail: gherro@spectrum-labs.com

1.2.5 University of Minnesota St. Anthony Falls Hydraulic Laboratory

The University of Minnesota St. Anthony Falls Hydraulic Laboratory (SAFHL) structure is located on
Hennepin Island at the head of St. Anthony Falls in the heart of Minneapolis. It is literally carved from
the limestone ledge forming the falls on the Mississippi River.

SAFHL's primary purpose is to provide a research program to support graduate studies in water
resources engineering and hydromechanics.

During the testing of the Kinetico SW224 Filter System, SAFHL provided the use of their facility, and
assisted COA in the installation, initial operations and equipment operation and monitoring during the
performance verification period.

Contact Information:

University of Minnesota

St. Anthony Falls Hydraulic Laboratory

Engineering, Environmental and Geophysical Fluid Dynamics

4


-------
Department of Civil and Mineral Engineering
Mississippi River at Third Avenue S.E.

Minneapolis, Minnesota 55414-2196
Phone(612)627-4010
Fax: (612) 627-4609

Contact: Scott Morgan, M.S., P.E. Research Fellow
E-mail: morga016@tc.umn.edu

1.2.6 U. S. Environmental Protection Agency

The EPA through its Office of Research and Development has financially supported and collaborated
with NSF under Cooperative Agreement No. CR 824815. This verification effort was supported by
Drinking Water Treatment Systems Pilot operating under the ETV Program. This document has been
reviewed for technical and quality content by the EPA.

1.3 Verification Testing Site

In March through May of 2000, the ability of the Kinetico SW224 Filter System to remove C. parvum
oocysts and G. lamblia was tested at the University of Minnesota SAFHL. A blend of untreated and
treated water from the Mississippi River was used for this verification test.

The test site was accepted by the manufacturer to represent a challenging surface water condition as
compared to an optimum condition for their equipment. While pH was not within the range the
manufacturer considers their equipment to perform at its best, it is within what is often encountered in
the field and as such appropriate for an ETV challenge.

1.3.1 Source Water

The SAFHL has direct access to untreated and treated Mississippi River water. Untreated river water
was supplied directly from an intake operated by the SAFHL. The Minneapolis Water Works
(MWW) treatment plant provided treated river water to the Hydraulic Laboratory through the
Minneapolis potable water distribution system.

The Mississippi River, at SAFHL's location, is considered part of the Upper Mississippi River Basin
area. The U.S. Geological Survey (USGS), U.S. Department of Interior, National Water-Quality
Assessment (NAWQA) program provides the following description of this area: Geology,
geomorphology, climate, hydrology and land covering this area control the occurrence and flow of
water, and the distribution of water-quality constituents. Landforms within this Upper Mississippi River
Basin are primarily results of Pleistocene glaciation. Soils developed on glacial deposits range from
heavy, poorly-drained clay soils developed on ground moraine to light, well-drained sands on outwash
plains. Agriculture is the dominant land use in the southern and western parts of the study area: forests
cover much of the northern and eastern parts of the basin area, and the Twin Cities (location of the
MWW) dominates the east-central part of the basin area.

5


-------
The Upper Mississippi's River Basin is underlain by glacial sediments and by a thick sequence of
limestone, shale, shaley sandstone and sandstone of Precambrian and Paleozoic age.

The climate of the Minneapolis, Mnnesota area is sub-humid continental. The average monthly
temperature ranges from -12° Celsius (°C), (11° Fahrenheit (°F)) in January to 23°C (74°F) in July.
Average precipitation at the MWW is 30 inches. About three-quarters of the annual precipitation falls
from April to September.

Mssissippi River water is treated at the Mnneapolis Water Works. The treatment plant is the largest
water utility in the upper Mdwest, producing an average of 70 million gallons per day (mgd). Peak rate
during the summer may be as high as 180 mgd.

At the MWW, water is withdrawn from the river and piped to the pumping station. From the pumping
station, the water is delivered to a softening plant. At the softening plant, lime is used for softening, and
alum is used for removal of color and turbidity. Dilute lime and alum slurry precipitates and settles out
during the softening process. Powered activated carbon is added to remove taste and order. The
water is then treated with carbon dioxide to lower the pH and stabilize the remaining hardness prior to
being pumped to one of two filtration plants.

At the filtration plant, chloramine (chlorine and ammonia) is added for initial disinfection, fluoride is
added for tooth decay prevention and ferric chlorine is added as a coagulant to remove remaining color
and turbidity. The water then enters a series of coagulation/sedimentation basins after which the water is
filtered with single, dual or mixed media filters. Blended poly/ortho phosphate is later added as a
corrosion control/inhibitor. The water is post chlorinated for final adjustment of the disinfectant residual
before being fed into the reservoirs and pumped into the distribution system.

The quality of the water is assured and controlled through the various stages of treatment by plant and
laboratory tests. An average of 500 chemical, physical and bacteriological examinations are done each
and every day (182,500 tests per year).

During the 32'/klay ETV test period, influent water to the Kinetico SW224 Filter System, which was a
blend of river water and treated water from the MWW, exhibited the following characteristics: turbidity
concentration average of 0.77 nephelometric turbidity unit (NTU), temperature range from 7.1°C to
15.4°C, pH in the range of 7.2 to 9.5, total alkalinity of 53 Mlligram per Liter (mg/L), total hardness of
80 mg/L, total organic carbon (TOC) concentration less than or equal to 6.4 mg/L, UV Absorbance @
254 nm of 0.082 to 0.108 cm"1, and true color of 10 Total Color Units (TCU). Iron was not detected
or was below the Practical Quantification Limit (PQL) of 0.1 mg/L. Manganese was analyzed at 0.02
mg/L or below the PQL of 0.01 mg/L throughout the testing period. Total coliform was measured six
times during the testing period. Five out of the six times no total coliform was measured or was below
the PQL of 1 Colony Forming Units (CFU)/100 milliliter (mL). Total coliform was measured one time
at 87 CFU/100 mL. During the testing period six samples were tested for algae. Five times out of the
six algae were not detected or were below the PQL of 1 Algae/mL. One Algae sample contained

6


-------
Nitzschia (genus within the group Diatoma of Algae) at a concentration of 25 Algae/100 mL. At the
test site, the blended, untreated and treated Mississippi River water, was dosed with liquid sodium
hypochloride to assure water supplied to the filtration equipment maintained a measurable, but low level
of free chlorine. Free chlorine measured in the filter influent during the test period averaged 0.78 ppm.
During protozoan seeding studies, sodium hypochloride was replaced with injection of sodium
thiosulfate to assure any free chlorine residual from the treated water supply was reduced to a level that
would not interfere with the seeding study. A summary of the influent water quality information is
presented in Table 1-1 below.

Table 1-1. Influent Water Quality (March 24- May 1,2000)

Parameter	Average Minimum Maximum Standard 95% Confidence

Deviation	Interval

Total Alkalinity (mg/L)

53

47

62

5

49, 58

Total Hardness (mg/L)

80

74

88

5

76, 85

TOC (mg/L)

6.4

6.1

6.5

0.1

6.3,6.5

UVA254 (cm"1)

0.098

0.082

0.108

0.011

0.088,0.108

Turbidity (NTU)

0.777

0.31

2.52

0.15

0.76,0.77

Free Chlorine (ppm)*

0.78

0.27

1.48

0.42

0.64,0.92

* - Free chlorine measurements taken during normal equipment operation (see Section 4.3.4.1 for measurements taken
during seeding).

1.3.2 Pilot Effluent Discharge

The effluent of the pilot treatment unit was discharged to Minneapolis Metropolitan sanitary sewer. The
Metropolitan Environmental Authority, which encompasses the Minneapolis Metro Area, maintains a
primary sewage treatment plant that discharges to the Mississippi River downstream of the Hydraulic
Laboratory. No discharge permits were required.

7


-------
Chapter 2

Equipment Description and Operating Processes
2.1 Historical Background

Filtration is the most ancient of all water treatment methods. The slow movement of water through
granulated media, commonly sand, coal or charcoal, has been employed as a civil engineering technique
for almost as long as water has been distributed in communities. Water that is muddied, discolored, or
contains debris of varying sizes, has long been poured through filter media and the accumulated debris
then scraped or backwashed away.

Only in recent times have scientists been able to quantify the collection of material within the filter bed,
especially the particulate matter—including microbes—that lie below our visual capabilities. We now
know that particles that we cannot see can also be removed by filtration. Still under study, however,
are the mechanisms through which particulate matter, including microscopic life forms, are accumulated
within the filter media.

It has been assumed that along with simple straining, which is the physical capture of particles too large
to move through the pores between the media granules, smaller particles are captured through other
attachment mechanisms. Most of those mechanisms involve a surface charge attraction of the
granulated media to the particle. Many experiments have been performed to better describe the
attraction process and to seek methods to improve it. Other mechanisms include particles that are
collected by impact on the surface of filter media granules as well as multiple particles bridging between
filter media granules.

The most common filtration system used in municipal treatment is the gravity filter, which uses the weight
or head of the water to force it through the filter at very low flow rates. Normal gravity filters, often
called "rapid" sand filters, have a normal flow rate of 3 gallons per minute (gpm) per square foot of
surface, or less. Other filters, such as slow sand filters, have even slower service flow rates.

Also listed among rapid sand filters are pressure filters, where the water is forced through a media bed
by high head pressures, and where the media bed is contained in a pressure vessel. They have bng
been used for iron and manganese removal, but have not been as readily accepted for surface water
treatment where microbial matter is of concern (Ten State's Standards, 1992). The advantages—
especially to small systems—of rapid sand pressure filters, are many. They are relatively passive
treatment systems, involve minimal operator attention, are low in cost and long-lived. Of concern,
however, is whether pressure filters can capture and contain particles that are small, and more
importantly, particles that may pose a threat to public health, such as the protozoan oocyst C. parvum.

C. parvum oocysts are small, from 4 to 6 microns (|im) in diameter, relatively spherical in shape, and
somewhat pliable. They have a slight electronegative surface charge which serves to keep them
separated from each other; that is, they behave as colloids in water suspensions (Cushen, 1996, Drozd,
1996, American Water Works Association (AWWA), 1992, Ongerth, 1996, Harter, 2000). G.

8


-------
lamblia cysts are slightly larger and elongated with one cross section 5 to 7 |jm in diameter, and the
other up to 15 |jm in cross section

2.2 Equipment Description

The equipment tested in this ETV program and shown in Figure 2-1, was the Kinetico SW224 Filter
System. The Kinetico SW224 is designed expressly for small system applications. Spatial size of the
Kinetico SW224 Filter System was 4' 1 '/t" W x 9' 6V2 L x 8' 1VI} H.

Media vessels (filters) measured 24" in diameter and 72" in height and are offered in fiberglass or steel
construction. Fiberglass reinforced polyethylene media tanks, pressure rated to 100 psi, were used for
this study. The liquid volume capacity of each media vessel is 119 gallons without media. Filter media
bed depth was 36". Sub-fill was not used. Total liquid volume capacity with media was at 87 gallons:

Tank manufacturer specifies 119 gallons as total tank capacity (or 15.91 ft3). Filter bed depth = 36".
Tank height is 72". Filter bed depth = 36", (or '/flf total tank volume of 15.91 ft3). Total media within
tank = V2X 15.91 = 7.96 ft3. Porosity of media is calculated from data found in Section 2.2, page 11.
Porosity = Specific gravity (2.23 g/cc) x Total intrusion volume (0.2098 mL/g) = .47 mL/cc (or 47%).

Total displacement of water within 7.96 ft3 of media bed with 47% porosity = (7.96 ft3 x 7.48 gallons
x 53%) = 30.96 gallons (or 31 gallons). Accordingly, total tank water volume = (119 gallons -
31.56gallons) = 87.04 gallons (or 87 gallons).

Two identical filters are used within the Kinetico SW224 Filter System. Filters are identified as "T1A"
and "T2A" and operating alternately.

The filter media is Macrolite®, a synthetic ceramic, filter media and is not included in AWWA standards
for filter media (B100-89). Standard B100-89 is a purchase guide for filter media and is not intended
as a design standard; however, many of the testing parameters will be of interest to public health
administrators, especially those physical characteristics that may impact on the longevity of the material.
Thus, hardness, specific gravity, acid solubility, uniformity coefficients, particle sieve size distributions
(within manufacturing lots and from lot to lot) and other similar physical data have been furnished by the
manufacturer and are noted below.

9


-------




7W turnwe mo irt colons anc »c norenr or
DNcnce HcaivoAUca imct n»c kin umc» id *ou
rot. a una tm mo nvot MwrMtM
comb m o«uena.in«ir ix miw mmemh
or m wwaa OMift or kxhco movcmu.
Momowur. i>c Mxm. mcimo> oaai mo ua

ra wremai row* « ccwmmt k* in ra

mCTml WWflKTKt



«r

tarn ME MR

WATER SYSTEMS
ismrasinMcirtN

midbud |mjow. |immt

m Mm \mm lia

0 | 1/28/98 1 PI0U80I 1 0

**« i/3--i]-o'l**w Ism

Figure 2-1. Schematic of the Kinetico SW224 Filter System

10


-------
Macrolite® of the 70/80 mesh size has a bulk density of 0.96 grams/cubic centimeter (cc). The specific
gravity (as measured by American Society for Testing and Materials (ASTM) EE840) is 2.23 g/cc.
The collapse strength for the media of this size has not been measured, however, for a larger sphere
(30/50 mesh) the collapse strength (as measured by ASTM D3102) is a nominal 7,000 psi for 10% and
nominal 8,000 psi for 20% collapse.

The uniformity of the Macrolite® 70/80 mesh media was analyzed in accordance with AWWA
Standard B100-96 by Bowser-Morner, Inc in December, 1997. The results of this analysis are
summarized below in Table 2-1.

Table 2-1. Uniformity of Macrolite® 70/80 Mesh Media (AWWA Standard B100-96)

Sieve Size, USA Std.	Nominal, mm	Effective, mm	Percent passing

#45

0.355

0.360

100.0

#50

0.300

0.307

99.9

#60

0.250

0.249

79.8

#70

0.212

0.212

28.9

#80

0.180

0.180

7.2

#100

0.150

0.150

0.4

Effective Size:	0.19 mm

Uniformity Coefficient: 1.2

In addition, a Kinetico Inc. internal laboratory analysis in June 1998 of 70 mesh media (Lot #352)
employing a mercury/penetrometer Micromeritics Autopore II 9220 instrument produced the following
results as shown in Table 2-2.

Table 2-2. Uniformity of Macrolite® 70/80 Mesh Media (Micromeritics Autopore

II9220)

Total intrusion volume

0.2098 mL/g

Total pore area

0.18 sq-m/g

Median pore diameter by volume (based on volume distribution curve)

53.7990 ^m

Median pore diameter by area (based on area distribution curve)

52.5351 (im

Median pore diameter (based on 4V/A)

46.5685 (im

The pore diameters are those measures by an instrument, AutoPore n, performing an intrusion study of
the media. A measured volume of the media was placed in a glass penetrometer which was then
degassed by vacuum. A known volume of mercury was introduced into the penetrometer which was
then placed under pressure. As the mercury penetrates the interstitial spaces, the volume is
electronically measured. The volumes and pore sizes are then calculated from the data by use of the
Washburn Equation. The total intrusion volume is the maximum volume of mercury at the highest
pressure; the total pore area is the area of the pore wall as calculated on the pore shape as a right
cylinder. The Median Pore Diameter (volume) is the pore diameter at the 50th percentile point on the
volume distribution curve; the Median Pore Diameter (area) is the pore diameter at the 50th percentile
point on the area distribution curve and the Average Pore Diameter (4V/A) is based on the total pore
diameter wall area of a right cylinder.

11


-------
A Material Safety Data Sheet for the Macrolite® was included as part of the FOD. Macrolite® media
meets the requirements of ANSI/NSF Standard 61 and is NSF certified.

Accessories and instrumentation included with the Kinetico SW224 System included flow rate and
pressure sensors and monitors, on-line turbidimeters, pressure gauges, backwash pumps and an
electrical enclosure containing a programmable logic controller and a touch screen monitor. The
equipment also contained data transfer connections available for remote monitoring.

The flow of water through the system is controlled with hydro pneumatically actuated valves mounted on
face piping constructed of Schedule 80 PVC. Automatic valves are actuated via a programmable logic
controller. The valves also have handles for manual activation.

Electrical power was required for operation of backwashing pumps, air compressor, analytical
instruments and system instrumentation.

The manufacturer claims the filter media is long lasting and estimates that less than 2% per year is lost to
attrition.

The filters are shipped skid mounted and absent of media. Filter media was loaded on site. The total
weight of the system, without media, is approximately 1,700 pounds.

A process design schematic of the Test Station, including the Kinetico SW224 Filter System, used to
conduct this ETV test is shown in Figure 2-2.

The Test Station supplied a mixture of raw Mississippi river water and fully treated Minneapolis City
water. The Test Station consisted of flow regulating valves, pumps, chemical metering pump, and
storage containers to maintain a consistent blend as measured by turbidity. An injection probe and on-
line static mixer were located at the outlet of the blending station for injection of (oo)cysts during
microbial challenge testing.

A Watts Reduced Pressure Zone (RPZ) backflow prevention device was installed on both the untreated
and treated water supply lines to the blending station to ensure (oo)cysts were not inadvertently
introduced into either stream.

While the manufacturer requires the Kinetico SW224 be supplied with chlorinated feed water,
chlorination equipment was not provided with the equipment package. Accordingly, the test station
included a liquid sodium hypochloride metering pump to assure a measurable concentration of free
chlorine was always present within the blended feed water supply. Further, during protozoan seeding
studies, sodium hypochloride was replaced with injection of sodium thiosulfate to assure free chlorine
residuals from the treated water supply was reduced to a level that would not interfere with the seeding
study.

12


-------
Untreated River
Water

Metering Valve

Municipal Water
Storage Tank
(250 Gallons)

Centrifugal Pump

Centrifugal Pump

RPZ
Backflow
Preventer

Liquid Sodium Hypochloride

Liquid Sodium Thiosulphate

Liquid Metering
Pump

Metering Valve

RPZ
Backflow
Preventor

Metering Valve



Blended V\feter



StorageTank



(250 Gallons)



f

I



Centrifugal Pump

RPZ
Backflow
Preventor

_ Minneapolis Public Drinking
Water Distribution System

Metering Valve

Note:

Sample taps, flow
meters, pressure
gauges are not
included within this
schematic.

Challenge Organisms
Suspended in Dl Water

Liquid Metering
Pump

Backwash/Rinse V\faste Line

Metering Valve

On-Line Turbidimeter

On-Line Particle Counter

Kinetico SW224

Sidestream Sample
Collection Station for
Challenge Organisms

On-Line Turbidimeter

On-Line Particle Counter

Sanitary Waste

Figure 2-2. Process Design Schematic Of The ETV Test Station for the Kinetico SW224 Filter System

13


-------
The following two photographs were taken of the equipment while it was on-site at the University of
Minnesota Hydraulic Laboratory for the verification testing.

Photo 1. Front view of the was Kinetico SW224 Filter System at the University of Minnesota

Photo 2. Side view of the Kinetico SW224 Filter System at the University of Minnesota.

14


-------
2.3 Operator Licensing Requirements

While limited operator experience is required, most states will require a licensed water treatment plant
operator to operate and maintain the system on a regular (daily) schedule. Operator training for small
systems filter operation is limited and offered by the manufacturer on delivery of a system. The
manufacturer requires no special license beyond that required by the state of local public health
authorities. Kinetico reports that licensing has not been an issue in prior installations of the equipment.
Operators of community water supplies have requirements that vary from state to state. In Minnesota,
there are four levels of community water plant operator qualification: A, B, C and D, depending on the
size of the community. At this time there is no requirement for licensing for operators of non-
community, non-transient public supplies; however the state is considering enacting such a requirement.
There is also no requirement for licensing for operators of transient, non-community public water
supplies, and there is little likelihood of such a requirement due to the nature of the owner/operator
status of most such facilities. Other states may have requirements beyond those noted here, although it
is expected that designers of public health water treatment installations will be familiar with any
requirements specific to their state or municipality. There may be possible Federal requirements
concurrent with the enactment of the Enhanced Surface Water Treatment Rule (ESWTR), but those are
not yet in effect.

15


-------
Chapter 3
Methods and Procedures

3.1 Experimental Design

The experimental design of this verification study was developed to provide accurate information
regarding the performance of the treatment system. The impact of the field operations as they relate to
data validity was minimized, as much as possible, through the use of standard sampling and analytical
methodology. Due to the unpredictability of environmental conditions and mechanical equipment
performance, this document should not be viewed in the same light as scientific research conducted in a
controlled laboratory setting.

3.1.1 Objectives

The verification testing was undertaken to evaluate the performance of the Kinetico SW224 Filter
System. Specifically evaluated were Kinetico's stated equipment capabilities and equipment
performance relative to water quality regulations. Also evaluated were the operational requirements and
maintenance requirements of the system. The details of each of these evaluations are discussed below.

3.1.1.1	Evaluation of Stated Equipment Capabilities

The experimental design plan was prepared to challenge the Kinetico SW224 Filter System for its
capability of removing viable C. parvum and G. lamblia.

3.1.1.2	Evaluation of Equipment Performance Relative To Water Quality Regulations

With increased awareness of pathogens resistant to traditional disinfection techniques, and with
implementation of the ESWTR and the Groundwater Rule in the near future, it is expected that the
search for alternative disinfection technologies will grow significantly. The current ESWTR requires a 2-
logio removal of C. parvum.

C. parvum oocysts are small, from 4 to 6 |im in diameter, relatively round in shape, and somewhat
pliable. They have a slight electronegative surface charge that serves to keep them separated from each
other; that is, they behave as a colloid in water suspensions (Cushen, 1996; AWWA, 1992; Ongerth,
1996; Harter, 2000). The purpose of the verification test is to demonstrate whether the Kinetico
SW224 pressure filter can act as a suitable barrier for these particles, preventing their passage into
drinking water.

3.1.1.3	Evaluation of Operational and Maintenance Requirements

An overall evaluation of the operational requirements for the treatment system was undertaken as part of
this verification. This evaluation was qualitative in nature. The manufacturer's Operations and
Maintenance (O&M) manual, experiences, and events that occurred during the verification period were

16


-------
used to develop a subjective judgment of the operational requirements of this system. The O&M
manual is attached to this report as Appendix B.

Verification testing also evaluated the maintenance requirements of the treatment system. Not all of the
system's maintenance requirements were necessary due to the short duration of the testing cycle. Pump
motors, flow meters and electronic monitoring devices required repairs as noted in the discussion
sections below. The O&M manual details various maintenance activities and their frequencies.

3.1.1.4 Evaluation of Equipment Characteristics

The qualitative, quantitative and cost factors of the tested equipment were identified, in so far as
possible, during the verification testing. The relatively short duration of the testing cycle creates difficulty
in reliably identifying some of the qualitative, quantitative operational and cost factors. The quantitative
factors examined during the verification were operational aspects of the Kinetico SW224 Filter System,
for example, the measurement of head loss, as well as other factors that might impact performance. The
qualitative factors examined during the verification testing process included, ease of operation and
troubleshooting. Costs associated with the system largely included power requirements. The operating
conditions were recorded to allow reasonable prediction of performance under other, similar conditions.
Also to be noted and reported were any occasional, anomalous conditions that might require operator
response such as high levels of algae growth, excessive turbidity spikes or frequent filter clogging. It is
important to note that the results obtained here are for the Kinetico SW224 Filter System. This
treatment system operated at 8.25 to 9.75 gpm/ft2 at 7.1°C to 15.4°C.

3.2	Verification Testing Schedule

The verification testing started on March 24, 2000 and continued for 32 '/days of operation and data
recording. During this period a total of 78 filter cycles occurred. Data was logged for a total of 779.5
hours of treatment system operation. The system was shut down for a total of 132.5 hours, between
April 12 and April 18, 2000 due to problems found in EPA Method 1623 associated with the testing of
Giardia muris (G. muris) versus G. lamblia. The DYNAL immunomagnetic separation (IMS)
technology used in EPA Method 1623 to concentrate and clarify protozoa samples cannot be used on
G. muris due to an extremely low affinity for the G. muris cysts. The shut down on the test unit was
due to the lead-time needed to secure the G. lamblia for the retesting. Original testing was performed
with G. muris due to safety considerations, because G. muris is not a human pathogen.

Microbiological challenge testing was performed during March 27 through March 29, and again during
April 24, 25 and 27, 2000. Daily testing concluded on May 1, 2000.

3.3	Initial Operations

An initial operations period was performed to allow the equipment manufacturer to refine the unit's
operating procedures and to make operational adjustments as needed to successfully treat the source
water. Initial operations procedures included a characterization of influent water, and establishment of

17


-------
operational data such as filter run times and backwashing schedules. Information gathered during
system start-up and optimization was used to refine the FOD. Adjustments that were made to the FOD
included:

Water temperature was recorded once per day due to the stable water temperature conditions
of the influent water.

Blending raw river water with finished municipal drinking water to achieve influent turbidity of
1.0 NTU provided water quality of minimal color. Therefore, color was not measured after the
first week of testing.

The flow rate across the filter bed was allowed to decrease as pressure differential across the
filter increased during each filter run. This was done to better emulate the true field operational
conditions of the packaged water treatment plant under test.

The Kinetico SW224 Filter System was on site in November of 1999. Shortly thereafter, the test
station was installed and plumbed to the filter system.

3.3.1 Characterization of Influent Water

The objective of the Initial Operations was to determine the suitability of the influent water to the
application of the technology.

The suitability of the influent water to the application of this technology was reviewed before testing.
Mississippi River data from past years from local and regional sources was compiled and analyzed with
respect to the biological, physical and chemical characteristics of the water. Parameters studied at the
verification testing site include (but were not limited to) the following: Turbidity, Temperature and
temperature variations within a season, pH, Total Alkalinity, Hardness, TOC, UV254 Absorbance, True
Color, Total Coliform, Algae (number and species), Iron, Manganese, and Free Chlorine. Review of
this data indicated that the technology should be suitable for this site.

Due to blending untreated river water with water from the Minneapolis public drinking water distribution
system chloramine residual was reduced. Accordingly, sodium hypochlorite was injected into the
blended during normal operation to elevate free chlorine to a detectable level. During the C. parvum
and G. lamblia seeding studies, injection of sodium hypochlorite was replaced with sodium thiosulfate
to remove chloramines carried over from Minneapolis drinking water supply within the blended water.

The parameters, which were analyzed as part of this testing and the sampling frequency, are presented
in Table 3-1, Section 3.4.

Intermittent factors that might influence water chemistry, such as weather, boat traffic, in and out-flows,
and bottom composition were noted in the logbook where appropriate. The Mississippi River has, by
the time it reaches this location, been exposed to municipal, industrial and agricultural use. The flow
past this point varies with the season, however typically exceeds 3,000,000 gallons per minute, and has

18


-------
been augmented by other rivers, somewhat less stressed by industry. The effects of most upstream
activity have been diluted accordingly.

3.3.2 Initial Test Runs

The purpose of the initial test runs was to establish operational data such as filter run times and
backwashing schedules, and to qualify the equipment for performance with the selected source water.

Initial test runs were performed to both terminal headloss and to turbidity breakthrough. Flow rate
variations and the character of effluent water were also studied to determine optimum operational
conditions. Backwashing was initiated when either a terminal headloss was reached or when turbidity
breakthrough occurred. Filters were backwashed until the waste stream ran clear, as determined by
turbidity of 5 NTU or less. Similarly, filters were rinsed (down flow) to waste until turbidity reached 0.5
NTU before they were put online. Terminal headloss was considered when a filter experienced a 22-
psi pressure differential between inlet and outlet.

Upon return to service, the filter ripening period was monitored and timed. These data were used to
determine the benchmarks for automatic backwash, rinse and run cycles during the testing and
verification period.

During initial operations, tracer tests using sodium chloride brine of approximately 313,000 mg/L
concentration were used to determine the amount of time required for a change in influent feed water
quality to be detected in the filter effluent stream, and then, the amount of time required for the
concentration of Total Dissolved Solids (TDS) in the effluent stream to become homogeneous with the
concentration of TDS in the influent stream. This information was needed to establish the start time and
length of effluent sample collection periods during microbial seeding challenges.

Tracer tests were conducted when the filter was in service and subjected to a process flow of 29 gpm.
The brine solution was injected into the influent stream with a metering pump and injection probe
previous to an in-line static mixer. Portable TDS meters were used to establish baseline concentrations
(mg/L dissolved solids) previous to brine injection. Previous to brine injection the metering pump was
primed and the tubing connected to the pump outlet to the injection probe was flooded with the brine
solution. Also, previous to injection sample taps located close to the outlet of the in-line static mixer and
on the filter effluent line were partially opened to allow a continuous flow rate of approximately 1 gpm.
Filter flow rate was verified with a rotameter and influent and effluent TDS meters were calibrated
against each other. A stopwatch was used to track time cnce the metering pump was started. Once
the brine injection commenced, sample cells of two portable TDS meters were triple rinsed and samples
collected every minute until the effluent sample TDS concentration elevated to the same concentration as
the influent sample and then continued for several minutes after this equilibrium was achieved. After that
point, the metering pump was stopped and injection of brine discontinued. Samples were collected
after that point with the same frequency to determine if TDS concentrations decreased at the same rate
and time as they had previously increased. Two tracer tests were conducted due to a TDS meter failure
during the first two minutes of the first tracer test.

19


-------
The use of sodium chloride brine over tracer dye in this application was preferable because dissolved
sodium chloride can be conveniently measured at small increments, thereby demonstrating both initial
and final concentrations; it dissolves readily and hence is not impeded by the filter; and after the tracer
test is complete, it is rinsed clean it leaves no residual on the filter media.

3.4 Verification Task Procedures

The procedures for each task of the verification testing were developed in accordance with the
requirements of the EPA/NSF Protocol (EPA/NSF, 1999). The Verification Tasks were as follows:

Task 1 - Verification Testing Runs and Routine Equipment Operation
Task 2 - Influent and Effluent Water Quality Characterization

Task 3 - Documentation of Operating Conditions and Treatment Equipment Performance
Task 4 - Microbiological Contaminant Removal Testing

Detailed descriptions of each task are provided in the following sections.

3.4.1 Task 1 - Verification Testing Runs and Routine Equipment Operation

The objective of this task was to operate the equipment provided by Kinetico for a minimum of a 30-
day period and assess its ability to meet water quality goals and other performance characteristics
specified by Kinetico.

The ETV protocol required the equipment be run continuously for a minimum of 30 days. One
verification test period was conducted over a total period of 32'/2days (779.5 hours). Verification
testing consisted of continuous evaluation of the treatment system, using the most successful treatment
parameters defined in Initial Operations. During this period the FTO attempted to provide influent
water quality consistent with the Kinetico's statement of performance capability of the equipment.
Influent water quality (turbidity and temperature) during this period ranged from 0.31 to 2.52 NTU, and
7.1°Cto 15.4°C.

Temperature, turbidity, other influent water quality parameters such as algae, natural organic matter, and
pH will influence filtration performance. In order to offer a "worst case" challenge to the equipment
under test, verification testing conditions included water of varying quality. Under these conditions a
total of 78 filter runs were monitored.

The Kinetico SW224 had control functions that allowed for differing conditions to initiate backwash.
The control functions that allowed backwash initiation due to headloss were verified as well as the
controls that initiated backwash based on turbidity breakthrough.

20


-------
Also tested was the ability of the filter to attain previous filter performance following an interruption of
flow. The Kinetico SW224 is configured to follow each interruption (stop-start) with a filter-to-waste
cycle. This aspect and the resultant particle distribution were evaluated.

Flow rate and total gallons produced are among the factors that were recorded.

Standard operating parameters for filtration and backwash were established through the use of the
manufacturer's O&M Manual and initial operations of the treatment system. After establishment of
these parameters, the unit was operated under those conditions.

3.4.2 Task 2 - Influent and Effluent Water Quality Characterization

Characterization of the influent water quality of the system was an important consideration in the
development of the experimental design of the ETV Test Plan. Water quality and microbial analyses
were selected to demonstrate the effectiveness of the manufacturer's equipment.

Analyses for G. lamblia, G. muris cysts and C. parvum oocysts were conducted during the microbial
removal phase of the evaluation. These analyses were conducted using procedures developed by the
EPA for use during the ICR for the identification and enumeration of G. lamblia cysts and C. parvum
oocysts, in particular Method 1623 (EPA, 1999). It was discovered during laboratory analysis that the
DYNAL IMS technology (prescribed in EPA Method 1623) to concentrate and clarify protozoa
samples could not be used on G. muris due to an extremely low affinity for the G. muris cysts.
Therefore, the microbial challenge testing was repeated, and G. lamblia was used for the retesting.

This task evaluated the water quality matrices of the influent and effluent water and identified the
composition of the removed particulate material with the relationship to terminal headloss and/or
turbidity breakthrough point. The collection of water quality parameters was performed as in Table 3-
1. Samples of both influent and effluent water were analyzed.

21


-------
Table 3-1. Analytical Data Collection Schedule

Parameter

Frequency

Influent

Effluent

On-Site Analyses
Temperature
pH

Turbidity
Particle Counts
Free Chlorine

Continuous
Continuous
Varied

Daily
Daily

X
X
X
X
X

X
X

Laboratory Analyses
Total Alkalinity
Total Organic Carbon
Total Hardness
UV Absorbance (254)
True color
Total Coliform
Algae
Iron

Manganese	

Once per period
Semi-weekly

Daily
Weekly
Weekly
Weekly

Weekly
Weekly
Weekly

X
X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X

All testing was performed in accordance with the procedures and protocols established as in Standard
Methods for the Examination of Water aid Wastewater 19th Edition (SM) or EPA-approved
methods. All on-site testing instrumentation or procedures were calibrated and/or standardized by FTO
staff. Evaluation of water quality in this task was related with respect to manufacturer's claims of
performance in addition to the SWTR.

Particle counts were evaluated and logio removals calculated by recording the change between the logio
of the influent and effluent particle counts in the ranges of 2-3 |j,m, 3-5 |j,m, 5-7 |j,m, 7-10 |j,m, 10-15
|j,m, and 15+ |j,m. The aggregate of particle counting data obtained during verification testing was
analyzed to determine the median logio removal and the 95th percentile logio removal during the test
period. The filter runs varied between approximately 1 and 24 hours. Filter run performance is
discussed further in Section 4.0, Results and Discussions.

3.4.3 Task 3 - Documentation of Operating Conditions and Treatment Equipment
Performance

The objective of this task was to denote the conditions surrounding the performance of the filter system,
including the physical instrument measurement of pressure losses at and prior to turbidity breakthrough.
Included in the performance parameters were flow rates (and any variations), pressures of influent and
effluent streams, length of filter runs, and backwash lengths.

Flow rates were measured with Data Industrial Corp. on-line flow rate sensors and flow monitor (Series
2100). Accuracy was verified by bucket and stopwatch technique. A utility power meter, reading in
kilowatt-hours, was attached to the power connection for the pilot plant.

The two filters were operated on an alternating basis near 30 gpm each at the beginning of each filter
run, as specified by the Manufacturer, for a throughput flowrate of 9.55 gpm/ft2 bed area. When one

22


-------
filter approached the end of the run, as determined by one of the conditions noted above, the stand-by
vessel was brought on line and the first filter was backwashed and placed into a standby mode. This
process was automatically controlled by electrically activated, motorized ball valves, with no discernible
loss of flow, and controlled automatically by the on-board programmable computer.

The Macrolite® media employed had a US sieve size of 70, as reported by the Manufacturer. This is
equivalent to 0.008 inches (0.2 mm or 210 |j,m) average diameter for each sphere. The pore size for
three such spheres that are touching leave a void that is 15.47% of the diameter of the spheres, or 32.5
|j,m, considerably larger than the size of C. parvum oocysts. Thus presumably, straining alone was not
the sole mechanism of removal.

Surface attachment mechanisms, none of which are entirely understood, most likely did not influence
contaminant removal. Some of the surface mechanisms had been related to pH and to ionic strengths as
well as to surface charges. The performance claim established for this ETV test was not for removal of
particulate matter only, but also for protozoan (oo)cysts; thus it was important to include challenges
employing viable (oo)cysts in this testing.

Treatment equipment operating parameters for both pretreatment and filtration were monitored and
recorded on a routine basis. This included a complete description of basis of initiation and operational
parameters for filtration, backwash and rinse cycles. Data on filter head loss and frequency/duration of
backwash cycles were also collected. Electrical energy consumed by the treatment equipment was also
measured and recorded. Data for rates of waste production were also collected.

Operating data included in the evaluation during the ETV test are itemized below in Table 3-2.

Table 3-2. Operating Data

Parameter	Frequency

Influent water and Filter Flow
Filter Headloss

Air Sparging
Backwashing

Electric Power
Hours of Operation
Filtered Water Production
Watershed Events

Checked and recorded 2 x /day. Recorded rates in logbook.

Recorded at beginning of run and at least twice daily; also recorded at end of

run or when breakthrough occurred when technician was present.

Recorded date, time and duration when technician was present.

Recorded date, time, influent and filtered water meter reading and calculated

filter effluent water volume. Noted terminal headloss prior to filter backwash.

Described reason for backwash; noted backwash rate and volume for each

backwash when technician was present.

Read meter once daily at same time.

Recorded daily at beginning of first shift.

Calculated total per filter run and total for each day per filter.

Recorded weather, snow melt, construction, excessive traffic or other events

that could impact source water quality daily at end of shift.	

3.4.4 Task 4 - Microbiological Contaminant Removal Testing

The objective of this task was to measure the ability of the filter to remove seeded microorganisms.
This portion of the study was of central importance, as it is the ability of the filters to remove the target

23


-------
microorganisms C. parvum and G. lamblia that is the primary claim of the manufacturer, and of
greatest interest to the public water community.

The mechanism for removal of viruses by the Kinetico SW224 was not under examination here (that is
beyond the scope of this ETV study). Here, only the ability to remove C. parvum and G. lamblia, to
detach them from the media during backwash, and to prevent re-entry into the process stream, was
challenged and verified.

3.4.4.1	Preparation of Microbial Doses

The C. parvum isolate used in this study was purchased from the University of Arizona and is also
referred to as the Harley Moon or Iowa strain. This strain was originally isolated from a calf and has
been maintained by passage through neonatal calves. A lot number was assigned to each calf on the
day the calf was infected and a batch number was given for the day the oocysts were shed. These lot
and batch numbers are recorded to validate oocysts' age. The oocysts excreted in the feces of
experimentally infected calves were isolated from the feces by discontinuous sucrose gradients followed
by microcentrifuge-scale cesium chloride gradients (Arrowood and Sterling, 1987; Arrowood and
Donaldson, 1996). The purified oocysts were stored at 4°C in 0.01% Tween 20 solution containing
100 units of penicillin, 100 |ig of streptomycin, and 100 |ig of gentamicin per mL to retard bacterial
growth. Oocysts were used within 90 days of isolation in all experiments.

The G. lamblia cysts were less than four weeks old, and were purchased from Waterborne Inc.
(additional information on the G. lamblia cysts is discussed in Chapter 4, Results and Discussions).
The cysts were stored in phosphate buffered saline without preservatives. At a field lab near the site,
Debra Huffman PhD., divided them into the required number of doses, and into the required
concentration of 108 oocysts and 107 cysts for injection into the water stream. The doses were
prepared by removing an aliquot of the enumerated (oo)cyst suspension and enumerating using the
method described in EPA Method 1623 (April 1999).

3.4.4.2	Analytical Schedule

There were three challenges employing a mixed cocktail of G. lamblia cysts and C. parvum oocysts.

During seeding studies, sodium thiosulfate was injected into the blended feedwater stream in place of
chlorine to reduce residuals within the filter influent water previous to the point of protozoan injection.
Measurements for free chlorine were conducted more frequently at these times to verify residuals had
been reduced to a level that would not impact C. parvum or G. lamblia during the study.

During the seedings, 10-liter samples for microbiological evaluation (identification and enumeration)
were taken from a side stream and filtered through a Gelman capsule filter for enumeration. Filter
influent and effluent grab samples were taken as follows:

#1—At initial start up

24


-------
#2—At the mid-point of the filter run

#3—At the end of the filter run, just prior to terminal headloss

These seedings allow determination of filter efficacy at several points in the filter cycle.

In addition, at a point in the middle of the run, the filter flow was stopped, and then restarted without a
backwash sequence following a brief interruption. Grab samples (as well as particle counter and
turbidity recordings) were taken immediately (within one bed volume) following the resumption of flow.
The objective was to determine if interruption of flow allows previously captured organisms to detach
from the filter media and re-enter the water stream. Pressure loss and flow data was also recorded
before and after the interruption.

This sequence was repeated during three successive runs of the same filter; the second and third runs
followed a run of the alternate, non-seeded filter. Since both filters are identical; only one filter of the
two was employed for seeding studies.

The inoculation point was through an injection probe at the intake of the static mixer. A 100 milliliter
graduated cylinder containing C. parvum and G. lamblia in suspension was connected by flexible
tygon tubing to an injection pump and probe that extended into the axis of the static mixer. Each
challenge test injected between 107 to 108 (oo)cysts concentrated into 100 milliliters of deionized water
containing 0.01% Tween 20. There were no additional detergents, wetting agents or other chemicals
added to the suspension. C. parvum and G. lamblia suspensions were injected into the influent stream
as a slug dose over a period of two to four minutes. The 100 mL graduated container used for the
original suspension was flushed three times with particle free sanitized water to void the excess (oo)cysts
though the injection stream.

The influent concentration of (oo)cysts was determined by hemacytometer count (EPA Method 1623)
based upon a grab sample from the influent container prior to injection.

The effluent concentration of (oo)cysts was determined based upon collection of a ten-liter sample using
a one micron pore size Gelman capsule filter per EPA Method 1623. The logio removal was
determined as follows:

Effluent Concentration ((oo)cysts/L) x Process Flow Rate (L/minute) x Collection time
(minutes) = Total (oo)cysts in the effluent.

The logio removal was determined using the calculation N/N0
where N= Total number of (oo)cysts in the effluent
No = Total number of (oo)cysts in the influent

During the seedings, 10 liters were collected from a side stream at a rate of 170 milliliters per minute
over a one-hour period (equivalent to 20 bed volumes) and filtered through a Gelman capsule filter for

25


-------
enumeration. The 10 liter samples filtered through a Gelman capsule filter were evaluated in accordance
with the procedures indicated in EPA Method 1623.

Simultaneous with the seeding, on-line particle counters located at the raw (seeded) water at the filter
inlet following the static mixer and at the effluent of the filter, recorded at an interval of every two
minutes for particles in the ranges of 2-3 |j,m, 3-5 |j,m, 5-7 |j,m, 7-10 |j,m, 10-15 |j,m, and 15+ |j,m.

3.4.4.3	Data Evaluation

Data from electronic particle counters were analyzed to determine the median logio removal as well as
the 95th percentile removal for the verification period. Particle count data were analyzed at one-hour
intervals, except during challenge periods where additional particle count data was correlated to grab
sample data times as closely as possible. The particle counter operated continuously, and recorded the
particle counts in the ranges of 2-3 |j,m, 3-5 |j,m, 5-7 |j,m, 7-10 |j,m, 10-15 |j,m, and 15+ |j,m. The data
was recorded electronically to display trends of particle count over time.

Turbidity was also evaluated continuously in two-minute intervals. The turbidity was recorded
electronically and correlated to the particle count data.

Protozoa densities of filtered water were analyzed by EPA Method 1623 for median logio removal and
95th percentile logio removal for each of the operating points noted above: startup following backwash,
midpoint, stop/start, and 85%-95% of terminal headloss.

3.4.4.4	Evaluation Criteria

All particle counting and turbidity data taken during the challenge period were correlated with the
microbial samples. Microbial results were compared with the logio removals for filtration processes in
the SWTR, and with respect to Kinetico's expected values of a 1.5-logi0 removal of C. parvum, and a
2-logio removal of G. lamblia.

3.5 Recording Data

The parameters and operating data collected by the technician were maintained in a bound logbook and
transferred to computer spreadsheets on a daily basis. Documentation of study events was facilitated
through the use of logbooks, photographs, data sheets and chain of custody forms. In addition any
variations in the treatment plant regimen were noted, such as changes in disinfection levels in response to
varying biological contamination and unusual source water episodes (i.e., weather related incidents (ice
outs, storms), unusual river traffic or contaminant spills).

Data handling is a critical component of any equipment evaluation testing. Care in handling data assures
that the results are accurate and verifiable. Accurate sample analysis is meaningless without verifying
that the numbers are being entered into spreadsheets and reports accurately and that the results are
statistically valid.

26


-------
The control system for the Kinetico SW224 Filter System included automatic data recording access and
automatic systems were employed where possible.

3.5.1	Objectives

The objective was to tabulate the collected data for completeness and accuracy, and to permit ready
retrieval for analysis and reporting. In addition, the use of computer spreadsheets allowed manipulation
of the data for arrangement into forms, useful for evaluation. A second objective was the statistical
analysis of the data as described in the "NSF/EPA ETV Protocol for Equipment Verification Testing for
Physical Removal of Microbiological and Particulate Contaminants" (EPA/NSF 1999).

3.5.2	Procedures

Data handling procedures were used for all aspects of the verification test. Procedures existed for the
use of logbooks used for recording the operational data, the documentation of photographs taken during
the study, the use of chain of custody forms, the gathering of on-line measurements, entry of data into
the customized spreadsheets, and the method for performing statistical analyses.

3.5.2.1	Logbooks

CO A as the FTO for the project was responsible for the maintenance of the logbooks and field
notebooks. Operational data was iead and recorded for each day of the testing cycle. Data was
collected in bound logbooks and on charts from the instrumentation panels and individual testing
instruments. There was a single field logbook containing all on-site operating data that remained on site
and contained instrument readings, on-site analyses and any comments concerning the test run with
respect to either the nature of the feedwater or the operation of the equipment.

The logbook was identified as Kinetico Backwash ETV Test and each page of the logbook was
sequentially numbered. Each completed page was signed by the on-duty FTO staff. Errors were
crossed with a single line and initialed. Deviations from the FOD whether by error or by a change in the
conditions of either the test equipment or the water conditions were noted in the logbook. The logbook
included a carbon copy of each page. The original logbook was stored on-site; the carbon copy sheets
were forwarded to the project engineer of CO A at least once per week. This not only eased
referencing the original data, but offered protection of the original record of results.

3.5.2.2	Photographs

Photographs were logged into the field logbook. These entries include time, date, and identity of the
photographer.

27


-------
3.5.2.3 Chain of Custody

Original chain of custody forms traveled with the samples from the test site to the laboratory (copies of
which are attached as Appendix E).

3.5.2.4	Inline Measurements

Data from a computer recording continuous inline measurements for turbidity and particle counts were
printed on a hard copy and copied to a disk on a daily basis. The data transfer disks were stored off
site, at the FTO's office.

3.5.2.5	Spreadsheets

A COA technician entered data into a computer spreadsheet program (Microsoft© Excel) on a daily
basis from the logbook and from any analytical reports. A back-up copy of the computer data was
maintained off site. The database for the project was set up in the form of custom-designed
spreadsheets. All data from the laboratory notebooks and the data logbook were entered into the
appropriate spreadsheet. COA technicians conducted data entry. All recorded calculations were
checked at this time. Following data entry, the spreadsheet was printed out and the printout was
checked against the handwritten data sheet. Corrections were noted on the hard copies and corrected
on the screen, and then a corrected version of the spreadsheet was printed out. The COA operator or
engineer performing the entry or verification step initialized each step of the verification process. The
data spreadsheets are attached to this report as Appendix C.

Each challenge test run was numbered for coordination with the on-site data from that run along with the
laboratory testing data. The operating conditions for each test run were entered into the logbooks and
onto the spreadsheet. The spreadsheet consolidated the information from Tasks 2, 3, 4, and the results
from oft-site laboratory analyses.

Computer data was transferred by the physical transfer of data disks.

3.6 Calculation of Data Quality Indicators
3.6.1 Representativeness

Water quality parameter samples for the Kinetico SW224 Filter System were taken as indicated in
Table 3-1. Off-site samples were delivered to the laboratory for analysis. The holding times are those
indicated in EPA 40 CFR, Ch. 1, § 136.3 and SM 1060. On-site samples were taken utilizing SM
1060 sampling techniques.

Operating data, such as flow rate, volume measurements and pressure gauges were recorded and the
time noted. Operational parameters were recorded and graphed.

28


-------
3.6.2 Statistical Uncertainty

Statistical 95% confidence calculations were performed for critical water quality data. Each of the
water quality parameters was analyzed, and confidence intervals determined by taking a minimum of
three discrete samples for each of the parameters at one operating set during the testing period.

The formula used for confidence interval calculations is:

Confidence Interval = X ± t

n-1,1-

S = standard deviation

n = number of measurements in data set

t = distribution value with n-1 degrees of freedom

a = the significance level defined for 95% confidence as: 1-0.95 = 0.05.

		f S ^

95%) Confidence Interval = X ±tn_l 0 975 —=

3.6.3 Accuracy

For water quality parameters, the accuracy referred to the difference between the sample result and the
true or reference value. Care in sampling, calibration and standardization of instrumentation and
consistency in analytical technique ensured accuracy.

For operating parameters such as flow rates and pressures, high levels of accuracy were ensured by
redundant testing by confirming flow meters with bucket and stopwatch measurements. Pressure
gauges were verified by reference to NIST-traceable standard gauges.

Performance evaluation was established by calibration of instruments used on-site and by conformance
to SM and EPA protocols. Although Spectrum Labs could perform similar analyses to those performed
on-site, the nature of the samples for pH, turbidity, temperature and chlorine levels, all tests of which
were subject to change upon transport and time delay.

Accuracy was measured by spiking a known value to a solute, or by using a standard sample. The
spiked (or standard) sample was analyzed and the following equations were used:

For a spiked sample:	%>R = 100

A - B

For a standard:	%>R = 100 x ^served

True

29


-------
Where:

%R
A
B
S

Recovery percent
Result of spiked sample
Result of un-spiked sample
Spike value

3.6.4 Precision

Precision was the measure of the degree of consistency from test to test, and was assured by
replication. In the case of on-site testing for water quality, precision was ensured by triplicate tests and
averaging; for single reading parameters, such as pressure and flow rate, precision was ensured by
redundant readings from operator to operator.

Travel blanks were not required for this testing.

Matrix and method blanks were used for turbidity measurements, pH standardization, and for
calibration of the particle counter both with respect to enumeration and size distribution.

Samples analyzed in duplicate or triplicate included bench-top turbidity measurements associated with
verification of calibration of the on-line turbidimeter.

The equation employed for precision was:

3.7 Equipment

In order to assure data validity, the EPA/NSF Verification Testing Plan procedures were followed.
This ensured the accurate documentation of both water quality and equipment performance. Strict
adherence to these procedures resulted in verifiable performance of equipment.

The following analytical equipment was used on-site during the verification testing:

A Hach 21 OOP portable turbidimeter (serial number 96090012047) was used for bench-top
turbidity analysis.

%RSD = D,/D2 x 100

%RSD

Di

D2

% Relative standard deviation
Standard deviation of sample set
Mean of recovery values (of replicates)

30


-------
Pressure gauges were Ametek 556L (0 to 100 psi) with calibration field verified with a National
Institute of Standards and Technology (NIST) traceable pressure gauge. There were four gauges
on the system. Pressure gauges were located on the inlet and outlet of each filter vessel.
• NIST-traceable Miller Weber Thermometer, Model P63C Serial number 3E7652 was used for
measurement of temperature.

A rotameter (Blue and White model F451004LHN) (0 to 40 gpm) and a paddle wheel (Burkart,
model #423-927B) were used to measure flow rates.

On-line turbidity measurements were taken with Great Lakes Model 95T/SS4_turbidimeters.
On-line particle count measurements were taken with Met One PCX particle counters (Serial
numbers: 000100288 and 000100292).

Chlorine measurements were taken with a HACH 2010 spectrophotometer.

Pressure were glycerin-filled Ametek 556L and Orange Research Differential pressure gauges.

The operating procedures for the Kinetico SW224 Filter System are described in Kinetico's O&M
Manual. The O&M Manual for the treatment system was maintained on-site and is attached to this
document as Appendix B. Additionally, operating procedures and equipment descriptions were
described in detail in Chapter 2, Equipment Description and Operating Process, of this report.

3.8	Health and Safety Measures

There was only one major safety concern for on-site staff with respect to this testing procedure. The
microbes used during the testing were highly infectious. For protection against accidental infection by
oocysts, strict environmental laboratory procedures were followed. Protective clothing such as gloves,
glasses and lab coats was on hand and used when appropriate. The capture filters removed from the
filtration housing were double bagged for shipment in protective containers. Laboratory personnel
trained in biological safety performed the handling of all live oocysts and oocyst-containing materials.

Built into the equipment were a number of safety features. Since this equipment has been designed for
installation in water treatment plants, interlock connections, breakers and other protective devices have
been included in its manufacture.

3.9	QA/QC Procedures

The objective of the Quality Assurance/Quality Control (QA/QC) procedures was to control the
methods and instrumentation procedures such that the data were not subject to corruption. Adherence
to analytical methods, both on site and off site, as published in Standard Methods or EPA-approved
methods was assured. Moreover, instrumentation and standard reagents were used in accordance to
NIST. Instruments used to gather data were standardized and calibrated in accordance with the
schedules noted below.

31


-------
3.9.1 QA/QC Verifications

QA/QC verifications were performed at the beginning of each testing period included instrumentation
checks, cleaning and maintenance of the turbidimeters, pressure gauges, tubing and other components.
Flow meters were calibrated with the "bucket and stopwatch" technique. Turbidimeters were tested for
volumetric accuracy and standardized. The particle counters were verified using calibrated
microspheres in the 2, 5 and 15 |im levels.

Results of the several verification and QA/QC procedures are detailed in the Chapter 4, Results and
Discussions section.

Daily QA/QC Verifications included:

On-line turbidimeter flow rates verified volumetrically with a 2,000 mL graduated cylinder and
stopwatch.

On-line turbidimeter readings standardized against a calibrated bench-top turbidimeter.
pH meter calibration verified at pH 7 and pH 10 with NIST-traceable pH buffers.

Bench-top turbidimeter calibration verified against standards of 0.1, 0.5 and 3.0 NTU.

On-line particle counter flow rates verified volumetrically with a 100 mL graduated cylinder and
stopwatch.

One-time QA/QC Verifications included:

On-line flow meters cleaned and flow verified volumetrically with a 55 gallon graduated
container and stopwatch. The flow rate through the system determined by stopwatch and
calibrated bucket, and compared to the flow rate as indicated on the flow meters and the results
noted in the logbook.

QA/QC Verifications at the beginning of each testing period included:

Cleaning and re-calibration of on-line turbidimeters; although required at the beginning of the
verification period, the nature of the test was such that the turbidimeters needed to be cleaned
much more frequently, a result to be discussed below.

Verification of particle counter calibration using NIST microspheres at 3, 5 and 15 |im size.
This procedure is noted in section 3.9.2.4 below.

Verification of pressure gauges with NIST-traceable gauge.

Inspection of particle counter and turbidimeter tubing for unimpeded flow and integrity.

Further descriptions on verifications of on-site instrumentation are provided below.

3.9.2 On-Site Analytical Methods

Specific instrumentation methods for on-site QA/QC are described below:

3.9.2.1 pH

Analysis of pH was performed according to SM 4500-H+, A two-point calibration with NIST-
traceable pH buffers of pH 7 and pH 10 was performed daily. Between tests the pH probe was kept
wet in KC1 solution. For on-site determination of pH, field procedures were used to limit absorbance of

32


-------
carbon dioxide to avoid skewing results by poorly buffered water. The samples were collected in a
dedicated beaker and promptly analyzed.

3.9.2.2	Temperature

Temperatures were measured in accordance with SM2550 daily. The thermometer used was a NIST-
traceable thermometer, marked n 0.1 °C increments. During initial operations, temperature did not
significantly fluctuate during any 24-hour period. Therefore, during the verification period, temperature
was measured once per day, rather than twice per day as proposed within the FOD.

3.9.2.3	Turbidity

The on-line turbidimeters remained on during the duration of the testing period. On-line and bench-top
turbidimeters were used for measurement of turbidity. The bench-top turbidimeter was the calibration
standard for the test. The on-line turbidimeters were further verified against a standardization cell
provided by the manufacturer, Great Lakes. The bench-top turbidimeter was calibrated at the start of
testing and then weekly according to manufacturer's instructions at 20, 100 and 800 NTU with freshly-
prepared Formazin suspensions. The provided Gelex vials were correlated with the turbidimeter for
verification between calibrations. In addition, prepared Formazin standards of 0.1, 0.5, 1.0 and 3.0
NTU were used to verify turbidimeter calibration. The bench-top turbidimeter was a Hach 21 OOP, and
is designed to shut off automatically after a specified period of inaction to preserve the battery;
accordingly, it was not left on at all times. Manufacturer's procedures for maintenance were followed
and the schedules for maintenance and cleaning noted in the logbook.

Samples were taken from a sample tap at a slow steady stream and along the side of a triple-rinsed
dedicated beaker to avoid air entrapment. Sample was poured from the beaker into a double-rinsed
clean sample vial and inserted into the chamber. This was repeated for influent and effluent samples,
and the reading of the on-line turbidimeter was noted when the sample was drawn.

All glassware for turbidity measurements were kept clean and handled with lint-free laboratory tissue.
Sample cells were additionally wiped with a silicone-oiled velvet cloth. SM 2130 protocol was
employed for measurement of turbidity.

3.9.2.4	Particle Counting

Two particle counters were used. Particle counters were factory calibrated by Hach Company using
polystyrene latex spheres traceable to NIST (certifications dated January 11, and 12, 2000). Particle
counter calibration was verified on-site with calibrated, mono-sized polymer microspheres. During the
verification period the calibration was verified by the use of NIST-traceable mono-sized particles.
Particle counter verification was performed for size distribution only, although counts were
corroborated. Particle counters cannot be field verified for count accuracy.

The procedure for monosphere verification was as follows, and as described in the ETV Test Plan.

33


-------
1)	Establish an initial analysis of particle concentration in the dilution water with the use of a particle
counter.

2)	To that dilution water add a sample of each size of the monospheres (2, 10, and 15 |jm) to
achieve a close approximation to 50,000 particles in 25 mL, swirl each suspension in turn.

3)	Quickly run suspension through the particle counter to determine that the peak concentration lies
at the size of the added monospheres.

4)	Prepare a suspension that combines all three of the particle sizes in a concentration of 1,000
particles of each of the three sizes (3,000 total) in 1 mL; swirl the suspension.

5)	Quickly run the suspension through the particle counter to determine that the particle counter
peaks at each of the three particle sizes, and in approximately the proper enumeration.

The above procedure, as described in the test plan, was designed for bench-top, batch type particle
counters and not on-line counters. The in line-counters require a different approach which is explained
below.

To one liter of dilution water an amount of particle suspension was added to measure approximately
2,000 particles per milliliter. The particle sizes were NIST-traceable for size and included 3 |jm, 10 |jm
and 15 |jm particles. Batch and true sizes are noted by Duke Scientific Corp. in the logbook as follows:

3.0 ± 0.027 |j,m
10.0 ± 0.061|j,m
15.0 ± 0.08 |j,m

This procedure was performed eight times, four each for the influent and effluent counters. Although the
test plan specified 2 (im, 10 (im and 15 (im sizes, CO A requested that the 2 (im size be replaced with 3
(im particles. Particle counting is done by segregating the particles into bins and since the lower limit of
the counter was 2 (im, the count of particles at that level would be uncertain. The verifications were
then performed with 3 (im, 10 (im 15 (im mono-sizes, and once with a mixture of all three sizes at the
1,000 particles per milliliter, or 3,000 particles per milliliter total.

Specially equipped hoses were attached to the influent and effluent ports of the particle counter sensor.
The influent hose was inserted into a flask containing either dilution water or the particle mixture, and the
effluent hose attached to a pump.

Dilution water was suctioned through the particle counter and the pump rate adjusted to 100 mL/min.
When the counts and flows were stable, the influent hose was switched to the particle suspension, which
was mixed gently with a magnetic mixer. Those particle counts were logged and the distribution noted
to assure separation into the proper particle count bin, and the time noted for correlation to the
computer data recorder. After several sensor readings, the hose was switched back to the dilution
water to clear the sensor and to stabilize the counter. During the procedure the flow was carefully
controlled at 100 mL/min, and exceptions noted since reductions or increases in the flow rate alter the
counts significantly.

34


-------
Maintenance of the particle counter is important. Manufacturer-recommended maintenance was
followed and noted in the logbook.

Procedures for particle counting were conducted as described in SM 2560 (and subsections
appropriate to the equipment in use).

3.9.2.5 Particle Free Water

Particle free water (PFW) was a necessary component of the testing procedure and was prepared fresh
and as often as storage limitations would allow. Fresh PFW was necessary to limit biological growth
that could affect the particle counts. Field conditions made the production of PFW in accordance with
SM difficult; however, commercially prepared DI water, filtered on site thorough a 0. |j,m filter was
suitable for particle counting suspension and other reagent preparation in this application. PFW was
subject to contamination by airborne particles after filtration. There was no clean room available on site.
Following consultation with the particle counter manufacturer, the FTO used MWW water filtered off-
site as dilution water. Since the particle counts were low (less than 99/mL), 1his was suitable dilution
water. As with turbidity, glassware associated with the particle counters was dedicated and cleaned
with laboratory glassware detergent, then triple rinsed with PFW.

3.9.3 Off-Site Analysis For Chemical and Biological Samples

Analytical procedures are described in BioVir's and Spectrum Laboratory's Quality Assurance Plans
(located in FOD). Tables la and lb of the Code of Federal Regulations 40 Parts 136.3 cross-
reference Standard Methods, EPA Methods, ASTM methods and U.S. Geological Survey (USGS)
methods. Spectrum Labs follows EPA, SM or other accepted methodology for all of their analytical
procedures. For example, to analyze alkalinity, EPA Method 310.1 is used; this correlates to SM
2320B, which is the same as ASTM 1067-92 and USGS i-1030-85. All four of the testing methods
are the same.

3.9.3.1	Organic Parameters: Total Organic Carbon and UV254 Absorbance

Samples for analysis of TOC and UV254 were collected in glass bottles supplied by Spectrum and were
delivered by courier to Spectrum Labs (the travel time was approximately 20 minutes). Samples were
preserved, held and shipped in accordance with SM 5010B and SM 1060. Samples were analyzed at
the laboratory for TOC by EPA Method 415.1. Samples were analyzed for UV254 using SM 5910B.

3.9.3.2	Microbial Samples: Coliform and Algae

Samples were collected in glass bottles supplied by Spectrum Labs and kept at 4°C in the proper
shipping cooler. Coliform samples were preserved with sodium thiosulfate. Because of the brief travel
time (less than 20 minutes) it was not considered necessary by the Spectrum Labs, to preserve algae
samples in Lugol's solution. Samples were analyzed for Total Coliform Bacteria and E. coli bacteria at

35


-------
the laboratory using the EPA MI Agar Method, (EPA 600 R 00 013), and algae using SM 10200F
(when algae were found, SM 10900 was used for speciation).

3.9.3.3	Inorganic Samples

Inorganic Samples were collected, preserved and shipped in accordance with SM 3010B and C and
1060 and EPA §136.3, 40 CFR Chapter 1. Proper bottles and preservatives where required (Iron and
Manganese for example) were used. Although the travel time was brief, samples were shipped cooled.
Samples were analyzed at the laboratory in accordance with the following methods: total alkalinity -
EPA Method 310.2, color - EPA Method 110.2, total hardness - EPA Method 130.1, iron - EPA
Method 200.7, and manganese - EPA Method 200.7.

3.9.3.4	True Color

True color was measured in accordance with SM 2120 at the beginning of the verification period. True
color readings did not impact on filter removal performance, unlike its effect on disinfection processes,
and were not measured after the first week.

36


-------
Chapter 4
Results and Discussion

4.1	Introduction

The verification testing for the Kinetico SW224 Filter System that occurred at the University of
Minnesota St. Anthony Falls Hydraulic Laboratory in Minneapolis, Minnesota, commenced on March
24, 2000, and concluded on May 1, 2000. The system was operated for a period of 321/xlays during
this period. Microbial challenge testing was performed twice. The first challenge test was performed
using G. muris and C. parvum as prescribed in EPA Method 1623. It was subsequently found that
the DYNAL IMS technology (also prescribed in EPA Method 1623) to concentrate and clarify
protozoa samples could not be used on G. muris due to an extremely low affinity for the G. muris
cysts. Because it would not be possible to replicate identical source water conditions at a later date,
comparative performance data for the reduction of G. muris and C. parvum could not be provided by
completing the analyses for only C. parvum from the first challenge series. Due to this limitation, in
addition to cost constraints, analyses for C. parvum were discontinued on sample from the first
challenge series. The Kinetico SW224 Filter System was then shut down between April 12 and April
18, 2000, for a total of 132.5 hours due to the lead-time needed to secure the G. lamblia for the
retesting. C. parvum and G. lamblia challenge testing was performed on April 24, 25 and April 27,
2000.

This section of the verification report presents the results of the testing and offers a discussion of the
results. Results and discussions of the following are included: initial operations, equipment
characteristics, effluent water quality, C. parvum and G. lamblia removal, and QA/QC.

4.2	Initial Operations Period Results

The objective of the initial operations period was to establish operational data including filter run times
and backwashing schedules, and to qualify the equipment for performance with the selected source
water. The initial operations period allowed the equipment manufacturer to refine the unit's operating
procedures and to make operational adjustments as needed to successfully treat the source water.

The unit was on site at the University of Minnesota in October of 1999 and was operated during initial
operations to establish the optimum treatment scheme prior to initiation of verification testing.

The major operating parameters examined during initial operations were characterization of influent
water, filter runs times and backwashing schedules.

4.2.1 Characterization of Influent Water

The SAFHL offered the FTO the ability to blend untreated river water with finished municipal drinking
water to achieve and maintain filter influent turbidity at a level specified by the equipment manufacturer.

37


-------
Historical untreated surface water quality data that was obtained from the City of Minneapolis Municipal
Water Works department and reviewed for the same time frame as the verification testing period
(March and April) exhibited the following characteristics: the temperature varied from 0.3°C to 13.2°C;
pH was in the range of 7.6 to 8.2; total alkalinity ranged from 103 mg/L to 169 mg/L; total hardness
ranged between 122 mg/L and 188 mg/L; true color ranged between 31 and 69 TCU and the turbidity
range was between 5.2 and 18.6 NTU.

Actual measurements taken by the City of Minneapolis Municipal Water Works for treated water used
during the verification testing period exhibited the following characteristics: the temperature varied from
0.2°C to 16.2°C; pH in the range of 8.0 to 9.2; total alkalinity ranged from 35 mg/L to 53 mg/L; total
hardness ranged between 67 mg/L and 96 mg/L; true color ranged between 3 and 11 TCU; and the
turbidity range was between 0.09 and 0.36 NTU. Review of this data previous to, and during the
testing period, confirmed that this site was suitable to conduct this equipment performance verification
test.

The water was blended from both sources to achieve the optimum characteristics for the system under
test. Filter influent turbidity levels were initially maintained close to 1 NTU. During the microbial
challenge test, this was reduced to an average of 0.6 NTU due to shorter filter runs being experienced
at that time.

4.2.2 Initial Test Runs

Some of information gathered during system start-up was used to refine the FOD. The adjustments that
were made included the following:

Water temperature was recorded once per day due to the stable water temperature conditions
of the influent water.

Blending untreated river water with effluent municipal drinking water to achieve influent turbidity
of 1.0 NTU provided water quality of minimal color. Therefore, color was not measured after
the first week of testing.

The flow rate across the filter bed was allowed to decrease as pressure differential across the
filter increased during each filter run. This was done to reflect actual operating conditions of the
packaged water treatment plant.

During the initial operations period the following items were also noted:

Before the verification testing period began, the Kinetico SW224 Filter System filters were backwashed
to remove media dust. This procedure was completed when the backwash turbidity meter values
stabilized. It required approximately sixteen backwash cycles per filter with city water to stabilize the
backwash turbidity.

Upon initial start up of filter runs, it was observed that the outlet turbidimeter indicated a value above the
programmed trip point of 0.5 NTU. This would send the filter on-line at that time into backwash mode.

38


-------
By inspecting the location of the sample port used to measure outlet turbidity, it was concluded that a
representative sample of the filtered water was not being supplied to the turbidimeter. Accordingly, the
manufacturer changed the location of the outlet turbidity meter sample port to a point where a
representative sample of filtered water could be supplied on a continuous basis.

It was noted that the pressure in the water line supplying blended water to the pilot was not adequate to
satisfy backwash flow requirements of one filter while the other filter was in service. Therefore, the
backwash water source was relocated. Finished city water was taken from an open storage tank and
repressurized via a backwash water pump (already incorporated into the pressure filtration module) to
satisfy filter backwash requirements.

Because filter effluent water was directed to the sanitary sewer (non-elevated) as compared to a water
tower (elevated), outlet sample taps remained non-pressurized. Therefore a manual metering valve was
installed downstream to create the backpressure necessary to make the outlet sample taps functional.

The Kinetico SW224 Filter System was run through multiple filter runs and backwash cycles during
initial operations. It was observed during this period that filter runs exceeded 24 hours when the
system's PLC was programmed to allow filter runs to continue beyond 24 hours. During initial
operations, backwash cycles were initiated based on turbidity breakthrough (established at 1 NTU) or
pressure drop (established at 22 psig). During the performance verification period the system's PLC
was programmed to discontinue a filter run if it exceeded 24-hours, regardless of headloss or effluent
turbidity values.

During air sparge it was observed that a little water would exit from the backwash turbidity meter
reservoir lid. Kinetico was consulted, and they indicated that the filter drain interval prior to air sparge
was too short. Kinetico then changed the drain interval factor in the software via modem connection.
This corrected the problem.

4.2.3 Hydraulic Flow Tracer Study

The purpose of the hydraulic flow tracer study was to establish hydraulic characteristics of the Kinetico
SW224 Filter System previous to microbiological challenges. Information from this study was used to
determine the start time and length of effluent sample collection periods relative t) seeding during
microbial challenges. The flow rates used for these hydraulic flow tracer studies were the same as for
the testing period (approximately 30 gpm).

Two tracer studies were performed using sodium chloride on March 27 and March 28, 2000 (Figure 4-
1 and 4-2). At the start of the first study a TDS meter failed during the first two minutes of the study
and was replaced with an alternate for the remainder of the study. Therefore COA conducted a second
study. The second study was conducted the same as the first and with the same process stream sample
ports.

39


-------
Time Elapsed (minutes)

—•— Effluent —A— Influent

Figure 4-1. Tracer Study #1

Time Elasped (minutes)

—•—Effluent —A—Influent

Figure 4-2. Tracer Study #2

Based upon the results of the above tracer studies, it was concluded that the one-hour side-stream
microbial sample collection period was sufficient and it should begin simultaneously with the slug-dose
injection of (oo)cysts.

40


-------
4.3 Verification Testing Results and Discussions

The results and discussions of testing runs, routine equipment operations, influent and effluent water
quality, operating conditions and equipment performance, and microbiological removal tasks of the
verification testing are presented below.

4.3.1 Task 1 - Verification Testing Runs And Routine Equipment Operation

The objectives of this task were to operate the equipment provided by the manufacturer for the 32'/klay
testing period and assess its ability to meet water quality goals and other performance characteristics
specified by Kinetico, Inc.

The verification testing for the Kinetico SW224 Filter System started on March 24, 2000 and continued
for 321/ilays of operation and data recording. During the performance verification period the equipment
was shut down for a total of 132.5 hours between April 12 and April 18, 2000 due to problems
encountered by the microbiological laboratory when using EPA Method 1623 for recovering of G.
muris versus G. lamblia. This shut down was due to the lead-time needed to secure the G. lamblia
for retesting. Due to this interruption, the Kinetico SW224 Filter System was not operated continuously
during the performance verification period. The actual time of equipment operation during the
performance verification period was 779.5 hours (321/klays).

By instruction of the Manufacturer, the initial target influent turbidity of 1.0 NTU was decreased to 0.60
and then to 0.70 NTU to help increase filter run duration.

The equipment provided by the manufacturer was designed to operate automatically, providing for
automatic backwash cycles to occur based upon turbidity breakthrough, pressure differential, or
elapsed filter run time of 24 hours. Because the ETV test protocol requires continued monitoring of
performance until terminal head loss occurs, the automatic backwash option based upon elapsed filter
run time was discontinued.

The only recurring problem that was problematic to the operation of the Kinetico SW224 filter system
involved the on-line turbidimeters. On-line turbidimeters supplied with the equipment package required
frequent cleaning and verification of calibration. Influent turbidimeter sensor cells were cleaned and re-
calibrated 25 times during the verification period. Effluent turbidimeter sensor cells were cleaned and
re-calibrated 63 times during the verification period. When turbidity readings began to increase
uncharacteristically fast, or when the PLC status screen alerted the operator of a turbidimeter problem
sensor cells were inspected and cleaned. The effluent water turbidimeter required the most
maintenance. Based upon visual inspection, filter media fines were typically found deposited within this
sensor cell. After completion of this ETV study, filter media was removed from the pressure vessels in
preparation to ship the Kinetico SW224 filter system. At that time significant loss of filter media was
not apparent. Kinetico estimates media loss at 2% per year to attrition.

41


-------
The backwash/rinse turbidimeter also required frequent cleaning and verification of calibration. The
backwash turbidimeters were cleaned and re-calibrated 21 times during the verification period. As in
the case with the effluent turbidimeters, filter media fines were typically found deposited within the
backwash turbidimeter sensor cell.

The filter runs averaged 11.7 hours, with an average of 21,075 gallons per filter run. Continuous
monitoring was not required and the technician was not on site during all filter runs; therefore data
averages are representative of runs that occurred during technician monitoring.

4.3.2 Task 2 - Influent and Effluent Water Quality Characterization

Temperature of the blended influent water varied during the testing period due to changes in the
Mississippi River water temperature. It ranged from a low of 7.1°C to a high of 15.4°C. Water
temperature did not steadily increase during the period, but advanced and declined as the air
temperatures changed. Fluctuations in water temperature were expected due to seasonal climatic
changes.

Results of on-line turbidity measurements taken throughout the entire verification period in the influent
and effluent water are presented in Table 4-1 below.

Table 4-1. Influent and Effluent Water On-Line Turbidity (March 24- May 1,2000)

Average	Minimum	Maximum	Standard	95%

Parameter	(NTU)	(NTU)	(NTU)	Deviation	Confidence*

Influent	0.77	0.31	2.52	0.15	0.76,0.77

Effluent	023	005	L16	0J3	0.23,0.23

* Note: Because on-line turbidity readings were taken every 2 minutes during the entire verification period (over
23,000 entries), the confidence interval is very small due to significant digits rounding.

Figure 4-3 demonstrates turbidity reductions achieved during the performance verification test period.

42


-------
1.50

0.00

Period of Performance (3/25/00 - 5/1/00)

-Influent Turbidity ¦ Effluent Turbidity
Figure 4-3. Daily Scatter Plots of Influent and Effluent Turbidity Values

A summary of the influent water quality information is presented in Table 4-2. Detailed laboratory
reports are provided in Appendix F. One sample for color detected 10 TCU. E.coli analyses were
conducted six times. Five samples of the six measured below the PQL of 1 CFU/100 mL. One sample
dated April 27, 2000, measured E.coli at 1 CFU/100 mL. Six samples were taken for Total Coliform
Bacteria. Analyses of five samples of the six did not detect Total Coliform Bacteria or measure above
the reported PQL of 1 CFU/100 mL. One sample of Total Coliform Bacteria taken on April 27, 2000,
recorded 87 CFU/100 mL.

One influent water sample dated March 27, 2000, for Total Coliform Bacteria and E.coli did not
contain a sufficient sample volume for a 100 mL analysis, thus an 80 mL analysis was performed.
Drinking water compliance samples (SDWA) must be 100 mL volumes to report <1 coliform/100 mL
or <1 E.coli/100 mL. This sample analysis must therefore be reported as <1/80 mL, or <1.25 per 100
mL (adjusting the PQL for the lower volume received and filtered). Therefore, Spectrum Labs deemed
that due to adjusting the PQL, data could be produced from the 80 mL sample for analysis. No
detection of Total Coliform Bacteria or E.coli was found in the 80 mL sample.

Algae were detected once in the influent water during the verification testing period on April 27, 2000,
as Nitzschia at a concentration of 25 Algae/mL. This detection for Algae in the influent water is not
considered outside the expected influent water conditions of this study.

43


-------
Table 4-2. Influent Water Sample Characteristics (March 24- May 1,2000)



#of







Std.

95% Confidence



Parameter

Samples

Average

Minimum

Maximum

Dev.

Interval

PQL

Total Alkalinity (mg/L)

6

53

47

62

5

49, 58

10 mg/L

Total Hardness (mg/L)

6

80

74

88

5

76,85

10 mg/L

TOC (mg/L)

6

6.4

6.1

6.5

0.2

6.2, 6.5

0.01 mg/L

UVA254 (cm4)

6

0.098

0.082

0.108

0.011

0.088,0.108

-

Iron (mg/L)

6

<0.1

<0.1

<0.1

0.0

NA

0.1 mg/L

Manganese (mg/L)

6

0.01

0.01

0.02

<0.01

NA

0.01 mg/L

pH

34

8.6

7.2

9.5

0.4

8.5, 8.7

-

Temperature (C)

34

10.3

7.1

15.4

2.0

9.5,10.9

-

Free Chlorine (ppm)*

11

0.78

0.27

1.48

0.42

0.64, 0.92

0.01**

Note: All calculations involving results with below PQL values used 1/2 the PQL in the calculation.

NA - Not Applicable because Standard Deviation = 0.

* - Free chlorine measurements taken during normal equipment operation (see Section 4.3.4.1 for absence of free
chlorine measurements during seeding studies).

** - This is the Estimated Detection Level (EDL) for free chlorine, this is not the same as the PQL. Hach
(manufacturer of the DRT/2010 Spectrophotometer) provides a value called the Estimated Detection Limit for USEPA
accepted and approved programs. The EDL is the calculated lowest concentration in a deionized water matrix that is
different from zero with a 99% level of confidence.

A summary of the effluent water quality information is presented in Table 4-3 and a detailed report is
presented in Appendix F. One sample for color was analyzed during the testing period at 5 TCU. Six
samples were taken for Total Coliform Bacteria. One sample dated April 27, 2000 reported 45
CFU/100 mL. Four of the other samples tested did not detect Total Coliform Bacteria above the PQL
of 1 CFU/100 mL. No algae were detected at the PQL of 1 Algae/mL in the effluent water samples.
E.coli was detected once on 4/26/00 at 1 CFU/100 mL. The remaining samples of E.coli were below
the PQL detection of 1 CFU/100 mL during the testing period. These low counts of Total Coliform
Bacteria and E.coli can be attributed to the practice of maintaining free chlorine residual in the influent
water (Table 4-2).

One effluent water sample dated March 27, 2000, for Total Coliform Bacteria and E.coli did not
contain a sufficient sample volume for a 100 mL analysis. Drinking water compliance samples (SDWA)
must be 100 mL volumes to report <1 coliform/100 mL or <1 E.coli/100 mL. This sample analysis
must therefore be reported as <1/90 mL, or < 1.15 per 100 mL (adjusting the PQL for the lower
volume received and filtered). Accordingly, Spectrum Labs deemed that due to adjusting the PQL,
data could be produced from the 90 mL sample for analysis. No detection of Total Coliform Bacteria
or E.coli was found in the 90 mL sample.

44


-------
Table 4-3. Effluent Water Sample Characteristics (March 24- May 1,2000)



#of





Std.

95%

Practical

Parameter

Sample; Average

Minimum

Maximum

Dev.

Confidence

Quantificatio











Interval

n Limit

Total Alkalinity (mg/L)

6 54

49

63

6

49, 59

10 mg/L

Total Hardness (mg/L)

6 78

73

87

5

74,82

10 mg/L

TOC (mg/L)

6 6.4

6.1

6.6

0.2

6.2, 6.5

0.4 mg/L

UVA254 (cm4)

6 0.098

0.086

0.106

0.008

0.091,0.105

-

Iron (mg/L)

6 <0.1

<0.1

<0.1

0.0

NA

0.1 mg/L

Manganese (mg/L)

6 <0.01

<0.01

0.01

0.0

NA

0.01 mg/L

NA - Not Applicable because the Standard Deviation = 0.

Due to the low residence time (Figure 4-2) and lack of chemical addition, effluent water temperature
and pH were not recorded.

Beyond these observations, there were no other significant changes in the influent or effluent water
quality characteristics during the verification testing period.

Table 4-4 and Figure 4-4 demonstrate the Kinetico SW224's ability to remove > 3 |im, < 7 |im sized
particles indigenous to the source water.

Table 4-4. Summary of Filter Influent and Effluent Particle Counts of >3 jim < 7 jim Sized Particles

Indigenous to the Source Water from On-Line Particle Counters





Average

Minimum

Maximum

Standard

95% Confidence

(#/mL)

(#/mL)

(#/mL)

Deviation

Interval (#/mL)

Influent >3(im,< 7 (im 3,179.16

209.85

7,942.20

573.56

3,171.75, 3,186.57

Effluent > 3 pm, < 7 pm 439.04

5.90

1,384.98

132.33

437.33,440.75

Note average log10 reduction of indigenous particles > 3 |im, < 7 (jm = 0.87

45


-------
5,000

4,000

E

5E 3,000

CO
0)

.£2 2,000

i_

(0
Q.

1,000

I i .j , :]

System shut down

.¦ ii111j|j I|i!|

li..l



ii!" ¦

¦

/¦ »',

Nil

¦

¦

"!

;Uit

; v • ',»¦

illihiihli

= _•	i. = , L t

! j11 i i

¦—i	1	r	P " ^ ^

1 ' , m

,! 11 i 11!,

Period of Performance (3/25/00 - 5/1/00)

¦Total Influent 3-7 • Total Effluent 3-7

Figure 4-4. Daily Scatter Plots of Influent and Effluent Particle Count Values of > 3 jim, < 7 jim Sized Particles
Indigenous to the Source Water

4.3.3 Task 3 - Documentation of Operating Conditions and Treatment Equipment
Performance

The purpose of this task was to accurately and fully document the operating conditions during treatment,
and the performance of the Kinetico SW224 Filter System during the Verification Testing run. During
this task, data was collected that described the operation of the equipment and provided information to
be used to develop cost estimates for operation of the equipment.

The following observations were also noted:

As described in Chapter 2, Equipment Description and Operating Processes, the Kinetico SW224
Filter System is a packaged water filtration plant designed to provide a continuous process flow and
automated to require minimal operator intervention. To support this design two filters are included
within the Kinetico SW224 package. When one filter is in operation, the alternate filter is off-line. Filter
run time is determined by one of the following events as monitored by the water treatment plant's PLC
with timers and sensors/meters installed within the appropriate process stream: Head loss; Turbidity
breakthrough; and Time. These values were initially set at 22 psi, .5 NTU and 24 hours, respectively.
When one of these set-point values is exceeded, the filter run is discontinued and the alternate filter is
rinsed and put on-line with minimal interruption in flow.

46


-------
The filtration system tested was designed for automatic vs. manual operation. Thus, it operated 24
hours per day. Due to this level of system automation, in conjunction with filter runs exceeding the 8-
hour technician-monitoring schedule, operational data such as maximum head loss were rarely recorded
immediately before the termination of a filter run.

It is observed from the operational data log (Appendix C) that during the performance verification
period, filter runs were usually terminated based upon a filter exceeding the maximum head loss set point
as compared to turbidity or run time set points. If terminal head loss did not occur during an operator's
shift the filters automatically alternated. Clean bed and terminal head losses could not be recorded in
such instances. COA recorded operational data beyond the required 8 hours/day, to 13 hours/day and
manually recorded operational data every hour in order to increase the probability of being present as
filter columns alternated. Even with this schedule, COA was not present to record these data on a
consistent basis. Listed below in Table 4-5 is a representative sample where data was recorded
throughout a filter run during the start, middle and end of the verification testing period.

Figure 4-5. Average Run Cycles At Beginning, Middle & End Of Performance Testing Period



Test

Filter

Beginnin

Ending

Change

Beginning

Ending

Change Gallons Backwas Backwas Backwas

Period

Run

g Flow

Flow Rate

in Flow Change in

Change in

in

Filtered

h Rinse

h Volume

h Flow

Time

Time

Rate

(gpm)

Rate

Pressure

Pressure

Pressur



Volume

(Gallons)

Rate

Frame

(hrs)

(gpm)



(gpm)

(psi)

(psi)

e (psi)



(Gallons)



(gpm)

Beginnin

19.94

29.70

28.47

-1.2

9

22

13

34,037

146

287

16

§

Middle

17.95

30.24

26.52

-3.7

9

21

12

30,847

183

285

16.5

End

6.50

30.15

27.27

-2.9

11

22

11

10,237

157

339

16.8

The Table 4-5 data is representative of data compiled from two runs selected for the beginning, middle
and end run cycles to replicate the data during that time frame. The data is also representative of runs
cycles in which a technician was able to observe and record the entire cycle.

Filter run times became shorter near the end of the verification test period. It is also noted that the
effluent turbidity set point was increased from 0.5 NTU to 10 NTU on 4/18/00. This change was in
response to problems that were being experienced with the outlet turbidimeter and occasional presence
of filter media within its sensor cell (as described in section 4.3.1) that caused the system to experience
multiple filter run - backwash cycles when an operator was not present to monitor and service the outlet
turbidimeter sensor. The maximum head loss set point was increased to 30 psi during microbial seeding
challenges to prevent the possibility of the filter run being automatically terminated during the 90% of
terminal head loss sample collection period.

A total of 1,307,850 gallons of water were filtered over a period of 32'/2days of operation (779.5
hours) including 78 filter runs. Average calculated flow rate for this period is therefore 27.98 gpm.
Recorded flow rates range from 24.72 gpm (4/25/00 @ 3:43 PM) to 30.48 gpm (4/26/00 @ 2:16
PM). Average calculated filter run volume is therefore 16,767 gallons. Technician recorded total filter
run volumes range from 5,163 gallons (4/28/00) to 44,347 gallons (3/26/00).

47


-------
During the 32'/klay verification testing period the Kinetico SW224 Filter System used 147 kWh for
1,307,850 gallons of water filtered. This equates to 8,897 gallons of filtered water per kWh.

Watershed events were noted in logbook. Data from the logbook and historical weather data from the
Minnesota State Climatology Office (DNR Waters) was compiled and is presented in Appendix G
detailing daily climatic events. A mild winter and extraordinarily high temperatures in February and
March lead to the occurrence of spring run-off and area lake ice-out dates to coincide with the ETV
test period. Lighter than average snowfalls, (typically 50 to 75 percent of average) and mild weather
contributed to reduced stream discharge (i.e., lower than average turbidity and particle count). Though
potential watershed events could lead to changes in water chemistry, which in turn could change filter
performance, these watershed events were minimized by the blending of river water and treated water
from the MWW.

4.3.4 Task 4 - Microbiological Contaminant Removal Testing

The purpose of this task was to demonstrate the Kinetico SW224 Filter System's ability to provide
reduction of C. parvum and G. lamblia within defined influent water quality specifications at a flow rate
of approximately 30 gpm. The challenge testing was performed on April 24, 25 and 27, 2000.

4.3.4.1 Water Characteristics

A blend of raw river and finished water served as the source water for this performance verification test.
The following influent water characteristics were observed during the challenge period: temperature
averaged 11.4°C; pH averaged 9.2; total alkalinity in the range of 50 to 52 mg/L; total hardness from
76 to 79 mg/L; TOC concentration of 6.4 mg/L; and UV254 absorbance in the range of 0.087 to 0.104
cm"1. Total coliform was measured twice during the challenge period. One sample result of the two
was below the PQL of 1 CFU/100 mL, the second sample measured 87 CFU/100 mL. Two samples
were tested for E.coli. The first sample was below the PQL of 1 CFU/100 mL, and the second E.coli
sample dated April 27, 2000 measured 1 CFU/100 mL. Iron was below the PQL of 0.1 mg/L.
Manganese was detected once at 0.01 mg/L. The second sample of Manganese was measured below
the PQL of 0.01 mg/L. Two samples were tested for Algae. Algae was detected in one influent water
sample on April 27, 2000 as Nitzschia at a concentration of 25 Algae/mL. The other sample of Algae
was below the PQL of 1 Algae/mL.

During seeding studies, the liquid metering pump previously used for chlorine injection was supplied with
sodium thiosulfate to assure the blended water did not contain free chlorine residuals at a level that
would negatively impact this study. Free chlorine measurements taken during the challenge period had
an average of 0.02 ppm, which is near the estimated detection limit (0.01 ppm) of the measurement
instrument (HACH DR/2010 Spectrophotometer).

The on-line influent turbidity during the microbial challenge testing ranged from 0.45 to 0.77 NTU, with
an average of 0.63 NTU. The on-line effluent turbidity during the challenge test ranged from 0.09 to
0.27 NTU, with an average of 0.17 NTU.

48


-------
The influent water temperature and pH during the microbial challenges were recorded as following:
challenge #1 temperature reading of 10.4°C and pH of 9.1; challenge #2 temperature of 10.8°C, and
pH of 9.5; challenge #3 temperature of 13.1°C, and pH of 8.8.

The following effluent water quality parameters during challenge testing period were observed: total
alkalinity in the range of 50 to 52 mg/L, total hardness between 75 and 78 mg/L, TOC concentrations
between 6.3 and 6.6 mg/L, and UV254 absorbance in the range of 0.089 to 0.102 cm"1. Total coliform
was measured twice during the challenge period. One sample of the two was below the PQL of 1
CFU/100 mL; a second sample had a reading of 45 CFU/100 mL. E.coli was below the PQL of 1
CFU/100 mL. Iron and manganese were not detected above the PQL of 0.1 mg/L and 0.01 mg/L
respectively during the challenge testing period.

4.3.4.2 Operational and Analytical Data Tables

The Kinetico SW224 Filter System included two identical filter vessels identified as "T1 A" and "T2A"
operating alternately. During the challenge testing only filter "T2A" was used for the challenge. Table
4-6 summarizes the operating conditions on filter "T2A" during the challenge testing.

Table 4-6. Operating Conditions During Each Protozoa Challenge Event



Challenge# Date Average Filter Flow Rate (Digital gpm)

Total Gallons Filtered

1 4/24/00 28.8

17.384

2 4/25/00 28.3

11,608

3 4/27/00 28.2

8.977

Figure 4-5 shows that the Kinetico SW224 Filter System removed an average of 0.75 logio (95%
Confidence Interval of 0.74, 0.76) of particles in the 3-7 |j,m size range during challenge test #1 on April
24, 2000. During this challenge #1, the average on-line influent turbidity as shown below in Figure 4-5
was 0.70 NTU, and the average on-line effluent turbidity was 0.29 NTU. It is also suspected the
influent turbidity did not increase during the first half of the filter run as figure 4-5 suggests. The sharp
decrease detected in influent turbidity at the approximate midpoint of the filter run coincides with an
entry within the field log book noting the influent turbidimeter sensor cell was cleaned at that time.

49


-------
Micro Sample Collection

£
O

o
3

¦c

d>

O)

o

0.0 •£

..£> $> & £> <£> <# £> <£>	t?> <£> <# £>

"S?5 ~v* ~v*

Micbial Seeding/Collection Times

Filter Pi in	Start FnH

Beginning 11:10 12:10
Middle 7:32 18:32
Stop/start 19:33 20:03

Time of day on April 24, 2000

End

20:14 21:28

-Log

.Filter Influent Turbidity

.Filter Effluent Turbidity

Figure 4-5. 3-7 |lm Particle Count Logio Removal and Turbidity Measurements During Challenge #1

Figure 4-6 shows the particle count logio removal and the turbidity measurements during challenge test
#2. This figure shows that the Kinetico SW224 Filter System removed an average of 0.82 logio (95%
Confidence Interval of 0.81, 0.84) of particles in the 3-7 |jm size range during challenge test #2 on April
25, 2000. During this challenge test #2, the average on-line influent turbidity as shown below in Figure
4-6 was 0.73 NTU, and the average on-line effluent turbidity was 0.15 NTU.

0.4

o.o

Micro Sample Collection

-ww

jflPW>llHKIH30H3HCiHlfl(Syjp

Stop/Start	I	I

^33



S/WW

71IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIn

0.2
0.0

°>- °>- ^	nk-	
-------
Figure 4-7 shows the particle count logio removal and turbidity measurements during challenge test #3.
This figure illustrates that the Kinetico SW224 Filter System removed an average of 0.85 logio (95%
Confidence Interval of 0.84, 0.86) of particles in the 3-7 |j,m size range during challenge test #3 on April
27, 2000. During challenge test #3, as shown below in Figure 4-7, the average turbidity as read by the
on-line turbidimeter was 0.54 NTU for the influent, and 0.16 NTU for the effluent. Again, as noted in
Figure 4-5, the sharp decrease in influent turbidity in figure 4-7 coincides with a cleaning of the turbidity
sensor cell.

0.00





,t*N

- of ^.N ^ nK-

Time of day on April 27, 2000

-Log

-Filter Effluent Turbidity '

¦Filter Influent Turbidity

Figure 4-7. 3-7 \lm Particle Count Log10 Removal and Turbidity Measurements During Challenge #3

4.3.4.3 Discussion of Results

The results of the three replicate challenge filter runs for Giardia lamblia are presented in Table 4-7.
The average cyst removal per filter run ranged from 1.6 logio to 3.7 logio with a mean of 2.4 logio, a
standard deviation of 0.6 logio, and a 95% confidence interval of ±0.4 logio.

51


-------
Table 4-7. Run 1-3 G. lamblia Logio Removal













(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

Run #

Giardia!L

Giardia!L

Process Flow

Collection Time

Total Giardia

Log10

Log10

Log10



Influent

Effluent

Liters/min

inMin

oocysts

Influent

Effluent

Removal

Run 1

















Start

700,000

0.2

116.77

54.0

1,261

5.8

3.1

2.7

Middle

1,000,000

1.0

107.27

60.0

6,436

6.0

3.8

2.2

Stop/Start



0.8

103.60

60.0

4,973







End

960,000

1.1

100.72

60.0

6,648

6.0

3.8

2.2

Run 2

















Start

660,000

0.2

116.20

60.0

1,394

5.8

3.1

2.7

Middle

960,000

0.7

105.60

59.0

4,361

6.0

3.6

2.4

Stop/Start



0.4

101.17

60.0

2,428







End

840,000

0.4

96.21

38.0

1,462

5.9

3.2

2.7

Run 3

















Start

3,800,000

0.1

116.50

64.0

746

6.6

2.9

3.7

Middle

2,000,000

6.6

107.95

47.0

33,486

6.3

4.5

1.8

Stop/Start



2.5

106.85

20.0

5,343







End

2.800.000

12.8

99.47

51.0

64.934

6.4

4.8

1.6

(1)	= BioVir result/5 (BioVir reported results/1 liter; actual influent volume was 200 mL)

(2)	= BioVir result organisms in capture filter (per liter)

(3)	= Average process flow during collection time (liters per minute)

(4)	= Effluent capture filter collection time (minutes)

(5)	= Columns 2x3x4 (total effluent organisms)

(6)	= Total number of organisms seeded (Logi0 of column 1)

(7)	= Total number of organisms released from filter system (Logi0 of column 5)

(8)	= Column 6 - Column 7

The results of the three challenge filter runs for Cryptosporidium parvum are presented in Table 4-8.
The calculated average oocyst removal per filter run ranged from 0 to 0.8 logio with a mean of 0.4 logio,
a standard deviation of 0.3 logio, and a 95% confidence interval of ±0.2 logi0.

52


-------
Table 4-8. Run 1-3 C. parvum Logio Removal



(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

Run #

Cryptolh

CryptofL Process Flow

Collection

Total Crypto

o

o

o

o

o

o



Influent

Effluent

Liters/min

Time inMin

oocysts

Influent

Effluent

Removal

Run 1

















Start

4,600,000

344.8

116.77

54.0

2,175,164

6.7

6.3

0.4

Middle

4,600,000

135.3

107.27

60.0

670,818

6.7

5.9

0.8

Stop/Start



5.5

103.60

60.0

34,188







End

3,600,000

137.7

100.72

60.0

832,149

6.6

5.9

0.7

Run 2

















Start

2,800,000

239.0

116.20

60.0

1,666,308

6.4

6.2

0.2

Middle

3,200,000

158.8

105.60

59.0

989,388

6.5

6.0

0.5

Stop/Start



8.0

101.17

60.0

48,562







End

2,800,000

131.2

96.21

38.0

479,665

6.4

5.7

0.7

Run 3

















Start

13,000,000

1,999.0

116.50

64.0

14,904,544

7.1

7.2

-0.1

Middle

9,600,000

716.0

107.95

47.0

3,632,733

7.0

6.6

0.4

Stop/Start



6.7

106.85

20.0

14,318







End

17.000.000

4.048.0

99.47

51.0

20.535.383

7.2

7.4

-0.1

(1)	= BioVir result/5 (BioVir reported results/1 liter; actual influent volume was 200 mL)

(2)	= BioVir result organisms in capture filter (per liter)

(3)	= Average process flow during collection time (liters per minute)

(4)	= Effluent capture filter collection time (minutes)

(5)	= Columns 2x3x4 (total effluent organisms)

(6)	= Total number of organisms seeded (Logi0 of column 1)

(7)	= Total number of organisms released from filter system (Logi0 of column 5)

(8)	= Column 6 - Column 7

The removal of G. lamblia cysts during each challenge were significantly greater than the removal of C.
parvum oocysts. This was expected as the G. lamblia cysts (9-12 |j,m) are larger than the oocysts
of C. parvum oocysts (4-6 |j,m) (Medema, 1998).

4.3.4.4 Stop/Start Event Evaluation

The flow of water through the Kinetico SW224 Filter System was discontinued soon after the midpoint
(oo)cyst seeding study during each of the three challenge filter runs. Filter effluent water was directed to
an (oo)cyst collection filter over a period of 60 minutes beginning immediately after the resumption of
flow though the filter. The collection period for the third challenge run was limited to 20 minutes due to
an unexpectedly short filter run. Turbidity and particle distribution counts were also recorded every two
minutes with the use of on-line sensors during each protozoan sample collection period.

4.3.4.4.1 Protozoan Sample Analyses

Analysis of filter effluent samples suggest G. lamblia cysts and C. parvum oocysts were released from
the filter bed as a result of this stop/start sequence. The number of (oo)cysts detected in the filter
effluent were considerably lower than the number detected during the midpoint seeding challenges.
Results specific to the stop/start sequence are presented in Table 4-9.

53


-------
Table 4-9. Run 1-3 Release of G. Lamblia, C. parvum Associated with Cessation and Resumption in Flow

Run #

(1)

(2)

(3)

Side-Stream Capture Filter
Collection Time in Min

(4)

Run 1









G. Lamblia

0.8

103.60

60.0

4,973

C. parvum

5.5

103.60

60.0

34,188

Run 2









G. Lamblia

0.4

101.17

60.0

2,428

C. parvum

8.0

101.17

60.0

48,562

Run 3









G. Lamblia

2.5

106.85

20.0

5,343

C. parvum

6.7

106.85

20.0

14.318

(1)	= BioVir result organism per liter in capture filter

(2)	= Filtration system flow rate in liters per minute

(3)	= Effluent capture filter collection time in minutes

(4)	= Columns 1x2x3 (total effluent organisms)

4.3.4.4.2 Turbidity and Particle Count Analyses

The above analyses represent the total number of (oo)cysts released from the filter bed based upon the
number collected within a single sample collection filter for up to one hour after the resumption of flow.
While the results provide a representation of the number of (oo)cysts released, there is some interest in
when they were released during the collection period. Of specific interest is the duration of time oocysts
were stripped from the filter bed as a result of the stop/start event as compared to what could be
expected from normal filter operation with uninterrupted flow. While this information cannot be
provided from the microbial analyses above, a study of turbidity and particle counts over the protozoan
collection period may provide some insight.

Because turbidimeters and particle counters cannot differentiate between (oo)cysts and other particles,
they cannot be used for direct measurement of (oo)cyst concentrations. Despite this limitation, there is
some confidence that (oo)cysts would be released into the filter effluent stream in the same pattern as
similarly sized indigenous particles following the cessation and resumption of flow. Accordingly, on-line
particle count data collected from the effluent stream were analyzed to determine the pattern of release
of particles close to the size of C. parvum oocysts (3 |j,m to 7 |j,m). These analyses are presented
below.

In Figure 4-8, flow was discontinued after the midpoint seeding of the first challenge run then re-started
at 19:33 hours. Effluent particle counts were recorded as zero previous to this point due to lack of flow
through the particle counter. Because the on-line particle counter recorded counts every two minutes,
the first value (1,417 particles per mL) was recorded after resumption of flow at 19:35 hours. At 19:37
hours, counts decreased considerably and were nearly stable after that point. Effluent turbidity values
demonstrated the same trend characteristics. Influent particle counts and turbidity remained relatively
stable between 19:33 and 19:37 hours.

54


-------
4,000

o

k.

O —

E E
>_

CO 0)
—' Q.

3,500

o
O

3,000

2,500

2,000

= 1,500

0
19

:31 19:33 19:35 19:37 19:39 19:41 19:43 19:45 19:47 19:49 19

1.00
0.90
0.80
0.70
0.60
0.50
0.40
0.30
0.20
0.10

0.00
:51

;o
'3

Time

~ Influent Total 3-7 • Effluent Total 3-7 Influent Turbidity	Effluent Turbidity

Figure 4-8. Turbidity and 3-7 (lm Particle Count Stop/Start During Protozoa Challenge #1

In Figure 4-9, flow was discontinued after the midpoint seeding of the second challenge run then re-
started at 13:50 hours. The first value recorded after resumption of flow was 942 particles per mL at
13:51 hours. At 13:53 hours counts decreased considerably and were nearly stable after that point.
Effluent turbidity values demonstrated the same trend characteristics. Influent particle counts and
turbidity remained relatively stable between 13:50 and 13:53 hours.

o

k.

o

E

hp

fO

O

o

0)

u

t
ra
Q.

4,000
3,500
3,000
2,500
2,000
1,500
1,000
500



Start flow at 13:50

1.00

0.90

0.80

0.70 S
H

0.60 Z
0.50 &
0.40 1

0.30
-- 0.20

0.10

	V	T	1	1	1	1	1	1	1	

13:45 13:47 13:49 13:51 13:53 13:55 13:57 13:59 14:01 14:03 14:05

0.00

Time

~ Influent Total 3-7 • Effluent Total 3-7 Influent Turbidity	Effluent Turbidity

Figure 4-9. Turbidity and 3-7 (lm Particle Count Stop/Start During Protozoa Challenge #2

55


-------
In Figure 4-10 flow was discontinued after the midpoint seeding of the third challenge run then re-
started at 10:35 hours. The first value recorded after resumption of flow was 602 particles per mL at
10:37 hours. At 10:39 hours, counts decreased and were nearly stable after that point. Effluent
turbidity values did not demonstrate the same trend characteristics. In this case, and as described in
Section 4.3.4.2, it is suspected that effluent turbidity values within Figure 4-10 were not accurate at this
time and until the sensor was cleaned and recalibrated at 10:43 hours. Influent particle counts and
turbidity remained relatively stable between 10:35 and 10:39 hours.

4,000 •

3,500 •

« -T 3,000 0-

o
O

¦- 2,500-

0)

Q.

 2,000-

0)

p 1,500-

— 1,000-

500 •

Start flow at 10:35

.00
J- 0.90
0.80
• - 0.70
Z ¦ 0.60

-- 0.

J - 0.

¦¦ 0.

~+ o.

0.

0 W	1	1	1	1	1	1	1	1	1	\- 0.

10:35 10:37 10:39 10:41 10:43 10:45 10:47 10:49 10:51 10:53 10:55

Time

50 ~
40 'B

L_

30 H
20
10
00

~ Influent Total 3-7 • Effluent Total 3-7 •

¦Influent Turbidity

¦ Effluent Turbidity

Figure 4-10. Turbidity and 3-7 (lm Particle Count Stop/Start During Protozoa Challenge #3

The above analyses suggest that indigenous particles of same approximate size of oocysts were released
from a filter bed within four minutes after the resumption of flow. To what degree this shedding period
is comparable to the period of time oocysts were also released is unknown, but it is suspected they
would be released in a similar pattern as indigenous particles of the same size.

To prevent hgh concentrations of particles from entering the filter effluent stream in the event of a
stop/start occurrence, the Kinetico SW224 Filter System employs a rinse to waste cycle previous to the
resumption of flow into the filter effluent stream. This rinse to waste cycle did occur in each of the three
stop/start episodes described above and likely accounts for the low effluent (oo)cyst concentrations
detected in the effluent stream during this stop/start evaluation. However, because elevated (oo)cyst
counts were detected once flow was directed to the filter effluent stream, consideration should be given
to increasing the duration of filter-to-waste cycle.

56


-------
4.4 Equipment Characteristics Results

The qualitative, quantitative and cost factors of the tested equipment were identified during the
verification period, in so far as possible. The results of these three factors are limited due to the
relatively short duration of the testing period.

4.4.1 Qualitative Factors

The qualitative factors examined during the verification were operational aspects of the Kinetico SW224
Filter System, specifically, susceptibility to changes in environmental conditions, operational
requirements and equipment safety, as well as other factors that might impact performance.

4.4.1.1	Susceptibility to Changes in Environmental Conditions

Changes in environmental conditions will influence the performance of the Kinetico SW224 Filter
System if they alter suspended particulate and/or algae concentrations, or pH. Higher concentrations of
suspended particulate matter will shorten filter run time between backwash cycles. Algae blooms,
especially of species known to disrupt filter performance will also decrease filter run times. Although,
given the alternating filter process design of the Kinetico SW224, shortened filter run times are of little
consequence other than elevating backwash and rinse water volumes.

Duration of filter runs decreased throughout the verification 32-'/day test period. While influent turbidity
was controlled rot to exceed 1 NTU, filter runs initially exceeding 24 hours decreased to less than 5
hours near the end of the test period. Because untreated water was blended with treated water to
achieve a 1 NTU equipment influent water quality specification, changes in raw water quality due to
spring run-off were minimized. Measured water quality parameters confirm this. Accordingly, it is
suspected that shortened filter runs can be attributed to changes in water quality parameters that were
not measured and/or a mechanical aberration within the filtration equipment being tested.

As stated by the Manufacturer, because the surface charge of filter media used within the Kinetico
SW224 filtration system is positive between pH 2.3 to 8.0 with a maximum positive charge between pH
3 to 4, filtration performance for the removal of G. lamblia cysts and C. parvum oocysts are enhanced
between this pH range.

The test site offered influent water conditions intended to present a worst case challenge for the Kinetico
SW224's ability to filter C. parvum and G. lamblia. Under more optimal conditions, with influent
water pH between 2.3 and 8.0, greater logio reductions may be exhibited.

4.4.1.2	Operational Requirements

The Kinetico SW224 Filter System was staffed eight hours per day. The operator was not on site for
the entire period of each of the 78 filter runs, therefore, a complete set of data for all of the filter runs
was not recorded. During 50 filter runs that were entirely observed by operators, it was noted that the

57


-------
equipment could virtually operate without operator interface. This being said, the recurring problems
encountered with the operation of the on-line turbidimeters, as previously described in Section 4.3.1,
would not allow for such hands-off operation of the treatment equipment.

4.4.1.3	Evaluation of O&M Manual

The O&M manual provided by the manufacturer primarily defined installation, operation and
maintenance requirements for Kinetico SW224 Filter System. The manual provided information
pertaining to basic installation, start-up, and operational process. A process schematic, trouble shooting
guide, and associated O&M manuals for components used within the Kinetico SW224 Filter System
were also provided. Warranty policies described within the O&M manual included those pertaining to
equipment and labor. The manufacturer also describes guarantees pertaining to the Kinetico SW224
Filter System's process and design.

The O&M manual was reviewed for completeness and used during equipment installation, start-up,
system operation, and trouble-shooting. It was found the manual provides adequate instruction for
tasks required to perform these functions over the period of operation of the ETV test period. In cases
where the operator desired to confirm his interpretation of instructions within the O&M manual,
Kinetico's customer support department proved to be responsive. In one such case, during initial
operations, Kinetico changed minor timing sequences controlled by the equipment's PLC via a phone
line modem connection.

4.4.1.4	Safety

The Kinetico SW224 Filter System did not introduce safety concerns beyond what is normally
expected in the operation of a small filtration system.

4.4.2 Quantitative Factors

Quantitative factors examined during the verification testing are limited to the review of power
requirements.

4.4.2.1 Power Requirements

Power use by the Kinetico SW224 Filter System was recorded by the use of a dedicated power meter.
During the 32'/klay verification testing period the Kinetico SW224 Filter System unit used 147 kWh for
1,307,850 gallons of water filtered. This equates to 8,897 gallons of filtered water per kWh.

4.5 QA/QC Results

The objective of this task is to assure the high quality and integrity of all measurements of operational
and water quality parameters during the ETV project. QA/QC verifications were recorded in the

58


-------
laboratory logbooks or spread sheets. QA/QC documentation and calibration certifications are
attached to this report as Appendix G.

4.5.1 Data Correctness

Data correctness refers to data quality, for which there are four indicators:

•	Representativeness

•	Statistical Uncertainty

•	Accuracy

•	Precision

Calculations of all of the above data quality indicators were outlined in the Chapter 3, Methods &
Procedures. All water quality samples were collected according to the sampling procedures specified
by the EPA/NSF ETV protocols, which ensured the representativeness of the samples.

4.5.1.1	Representativeness

Operational parameters graphs and discussions are included under Task 3 - Documentation of
Operations Conditions and Treatment Equipment Performance. Individual operational parameters, such
as flow rate, particle count data, turbidity data, and testing equipment verification are presented below in
discussions on Daily, One-Time and Start of Testing Period QA/QC Results.

4.5.1.2	Statistical Uncertainty

Ninety-five percent confidence intervals were calculated for the water quality parameters of the Kinetico
SW224 Filter System. These include influent and effluent turbidity, particle count, and various other
filter runs performance data as discussed in Task 3 - Documentation of Operations Conditions and
Treatment Equipment Performance. Ninety-five percent confidence intervals were also presented in the
water samples summary tables in the discussion of Task 2 - Influent and Effluent Water Quality
Characterization.

4.5.1.3	Accuracy

For this ETV study, the accuracy refers to the difference between the sample result, and the true or
reference value. Calculations of data accuracy were made to ensure the accuracy of the testing
equipment in this study. Accuracy of parameters particle count data, turbidity data, and testing
equipment verification are presented below in discussions on Daily, One-Time and Start of Testing
Period QA/QC Results.

59


-------
4.5.1.4 Precision

Precision is a measure of the degree of consistency from test to test, and can be measured by
replication. Precision was ensured by verifying replicated field and lab measurements were within 30%
of the relative standard deviation of each sample set. Both influent and effluent turbidity was within 30%
of the relative standard deviation. For single reading parameters, on-site, such as pressure, pH and flow
rates, precision was ensured by calibration of analytical equipment and redundant readings from
operator to operator. Calibration procedures and results are presented in QA/QC Results.

4.5.2 Daily QA/QC Results

The on-line influent turbidimeter flow rate averaged 1,192 mL/minute. This average was calculated only
to show that the limits were observed. The maximum rate during the testing period was 2,280
mL/minute; the minimum was 880 mL/minute. The acceptable ranges of flows as specified by the
manufacturer are 190 mL/minute to 26,582 mL/minute. The turbidimeter readings are accurate within
those ranges; however, the time from beginning of flow to stable turbidity indication is lengthened with
the lower flows. The on-line effluent turbidimeter flow rate averaged 2186 mL/minute. The maximum
rate during the testing period was 2,320 mL/minute; the minimum was 2,020 mL/minute.

Values from the GLI Model 95T/8320 on-line influent and effluent turbidimeters averaged 0.77 and
0.23 NTU respectively during the verification test period. Values from the Hach 21 OOP bench-top
turbidimeter averaged 0.64 and 0.25 NTU respectively for filter influent and effluent water samples.
On-line turbidimeter readings were compared against bench-top turbidimeter readings daily. The RPD
between these sets of comparative online vs. benchtop values for influent and effluent samples, were not
within 30%) on a consistent basis (refer to Appendix G). This variation is thought to be partly
attributable to measurement of turbidity values near the limitations of measurement of the sensors, and
partly attributable to possible scratches on the on-line turbidity sensor caused by the occasional
presence of media fines within the sensor cells.

The influent water particle counter flow rate averaged 100 mL/minute. The flow rate of the cn-line
influent water particle counter was determined using a graduated cylinder and stopwatch. The maximum
flow rate measured was 103 mL/minute; the minimum was 98 mL/minute. The target flow rate specified
by the manufacturer is 100 mL/minute. Efforts were made to keep the flow rate at 100 mL/minute and
the flow was adjusted whenever those boundaries were crossed. The effluent water particle counter
flow rate averaged 100 mL/minute. The flow was measured using a graduated cylinder and stopwatch.

The pH meter was calibrated daily against NIST-traceable pH buffers of 7.0 and 10.0. The pH meter
was a Cole Palmer Oakton® WD-3 5615 Series. The pH calibration buffers were Oakton pH Singles
7.0 (model #35653-02), and pH Singles 10.0 (model #35653-03). The pH calibration was performed
prior to the recorded inlet pH measurement. pH meters were calibrated to standards previous to each
pH measurement to ensure accuracy of measurement.

60


-------
4.5.3 One-Time QA/QC Verification Results

Verifications of the on-line flow meters were performed once during the testing period.

Digital flow meters provided with the test unit were verified by bucket and stopwatch using a measured
container on April 30, 2000. Flows were measured at 29.03 gpm three times. Comparative flow
displayed by the digital flow meters 29.07, 28.80, and 29.10 gpm. This represents an average error of
-0.04 gpm, or 0.14%. This was within acceptable limits.

Flow rate rotameter readings were verified by bucket and stopwatch using a measured container on
April 30, 2000. Flows were measured at 29.03 gpm three times. Comparative flows displayed by the
rotameters were 29.8 gpm three times. This represents a factor of error of -0.77 gpm or 2.65%. This
was within acceptable limits.

The Burkert 8035 on-line flow meter was verified by bucket and stopwatch using a measured container
on April 30, 2000. The Burket flow was measured at 30.72, 30.90, & 30.80 gpm. The
bucket/stopwatch was measured at 29.03 gpm three times. This represents a factor of error of +1.77
gpm, or 5.8%).

4.5.4 Results Of QA/QC Verifications At The Start Of Each Testing Period

Accuracy of on-line flow rate meters were verified once at the end of the testing period when plumbing
revisions could be made to accommodate this procedure.

The tubing and all water lines used on the treatment system were inspected at the beginning of the testing
period (March 25, 2000). The tubing and lines were checked periodically throughout the testing
period. They remained in good condition and replacements were not necessary.

Particle counters used on site were Met One PCX models. The particle counters were calibrated by
HACH Company using polystyrene latex spheres traceable to NIST standards. Particle counters used
on site had a HACH Company factory calibration certificate dated January 11, and 12, 2000.

Calibration was verified on site with NIST mono-sized polymer microspheres on April 29, 2000 as
described in Section 3.9.2.4 above. The following figures show the distribution as counted by the
MetOne particle counter during the NIST-traceable verification of calibration using 500 mL of a
microsphere dilution as detailed below for each verification test.

Figure 4-11 shows the particle counts during the influent 3 |j,m verification using 500 mL of a
microsphere dilution (5 x 107/mL, 0.04 mL concentration to 1 Liter PFW). The Figure shows the
addition of the added particles in the 3 |j,m size range as would be expected.

61


-------
0 ¥=

15:21

15:23 15:25 15:27
Time of day on April 29,2000

15:29

Figure 4-11. Verification of 3 |lm Influent Particles

Figure 4-12 shows the particle counts during the influent 10 |j,m verification using 500 mL of a
microsphere dilution (1 x lOVrnL, 2 mL concentration to 1 Liter PFW). This Figure shows the addition
of the added particles as would be expected in the 10 |j,m size range.

-Influent P:2-3
-Influent P:3-5
-Influent P:5-7
-Influent P:7-10
-Influent P:10-15
-Influent P:15+

14:43 14:45 14:47 14:49 14:51
Time of day on April 29, 2000

1400
1200
1000
800
600
400
200
0

14:41

Figure 4-12. Verification of 10 |lm Influent Particles

Figure 4-13 shows the particle counts during the influent 15 |j,m verification using 500 mL of a
microsphere dilution (1 x lOVrnL, 2 mL concentration to 1 Liter PFW). This Figure shows the addition
of the added particles in the 15 |j,m range as expected.

62


-------
14:17 14:19 14:21 14:23
Time of day on April 29,2000

14:25

Figure 4-13. Verification of 15 |lm Influent Particles

Figure 4-14 shows the particle counts during the influent "cocktail" mix of 3, 10 and 15 |j,m verification
using 500 mL of a microsphere dilution (1 mL of 15 |j,m, 1 mL of 10 |j,m. 0.02 mL of 3 |j,m to 1 Liter
PFW). The Figure shows the addition of the added particles in the 3, 10 and 15 |j,m size range as
would be expected.

1200

-	Influent P:2-3

-	Influent P:3-5

-	Influent P:5-7
-Influent P:7-10
-Influent P:10-15
-Influent P:15+

15:41	15:43	15:45

Time of day on April 29,2000

15:47

Figure 4-14. Verification of Mix of 3,10 & 15 |lm Influent Particles

Figure 4-15 shows the particle counts during the effluent 3 |j,m verification using 500 mL of a
microsphere dilution (5 x 107/mL, 0.04 mL concentration to 1 Liter PFW). The Figure shows the
addition of the added particles in the 3 |j,m size range as expected.

63


-------
V)

0)

o

r

ro

CL

-	Effluent P:2-3
-Effluent P: 3-5
-Effluent P: 5-7
-Effluent P:7-10
-Effluent P: 10-15

-	Effluent P: 15+

15:11 15:13 15:15 15:17
Time of day on April 29, 2000

15:19

Figure 4-15. Verification of 3 \im Effluent Particles

Figure 4-16 illustrates the particle counts during the 10 \xm effluent verification using 500 mL of a
microsphere dilution (1 x 106/mL, 2 mL concentration to 1 Liter PFW). The Figure shows the addition
of the added particles in the 10 \im size range as expected.

-	Effluent P:2-3

-	Effluent P:3-5

-	Effluent P:5-7
-Effluent P:7-10

-	Effluent P:10-15
-Effluent P:15+

14:51 14:53 14:55 14:57
Time of day on April 29,2000

14:59

Figure 4-16. Verification of 10 |lm Effluent Particles

Figure 4-17 illustrates the particle counts during the 15 |j,m effluent verification using 500 mL of a
microsphere dilution (1 x 106/mL, 2 mL concentration to 1 Liter PFW). The Figure shows the addition
of the added particles in the 15 |j,m size range as expected.

64


-------


1200



1000

VI

800

0)



O



t

600

ra



Q.





400



200



0

-Effluent P:2-3
-Effluent P:3-5
-Effluent P:5-7
-Effluent P:7-10
-Effluent P:10-15
.Effluent P:15+

14:07 14:09 14:11 14:13
Time of day on April 29, 2000

14:15

Figure 4-17. Verification of 15 (lm Effluent Particles

Figure 4-18 illustrates the particle counts during the "cocktail" mix of 3, 10, and 15 |j,m effluent
verification using 500 mL of a microsphere dilution (1 mL of 15 |j,m, 1 mL of 10 |j,m, 0.02 mL of 3 |j,m
to 1 Liter PFW). The Figure shows the addition of the added particles in the 3, 10 and 15 |j,m size
range as expected.

-Effluent P:2-3
-Effluent P:3-5
-Effluent P:5-7
-Effluent P:7-10
-Effluent P:10-15
-Effluent P:15+

15:47 15:49 15:51 15:53 15:55
Time of day on April 29, 2000

Figure 4-18. Verification of 3,10 & 15 \im Effluent Particles

The addition of particles in the effluent and influent samples were recorded via the particle counter
during the verification process.

65


-------
Particles that were added were:

Duke Scientific Corp	3.0 ± 0.027 |j,m

10.0 ± 0.061 |j,m
15.0 ± 0.08 |j,m

Visual inspections of the particle counter and turbidimeter tubing showed unimpeded flow and integrity.
The tubing was also inspected periodically throughout the testing period, no replacements were
necessary.

Pressure gauges were verified on March 28, 2000 by comparing the pressure shown on the gauge with
the pressure shown on a MST-traceable pressure gauge (Identification Number 9286-11). The inlet
gauge had a reading of 53 psig, while the corresponding MST-traceable gauge had a reading of 53.25
psig. The outlet gauge had a reading of 41 psig, and the corresponding NIST-traceable reading was 41
psig. Differences between the gauges were acceptable, and no further verification was needed.

CO A performed calibration procedures on the bench-top, Hach 21 OOP turbidimeter. The instrument
was calibrated to the manufacturer's recommended standards of 20, 100 and 800 NTU with fresh
Formazin suspensions. Standards were made with dilutions from a standard Formazin suspension of
4,000 NTU. NIST-traceable glassware, including pipettes and volumetric flasks were used.

The manufacturer explains that since the response signal is linear from 0-20 NTU efforts to standardize
to lower levels are fruitless and may instead throw the readings off. Calibration standards are further
required to be at least 65 NTU apart. In addition, weighting the curve to the range of interest (in this
case at levels less than 5 NTU) also provides the opportunity for increasing error. The manufacturer's
recommended settings were also observed in subsequent calibrations.

Fixed Gelex secondary standards were correlated with the instrument following calibration, which was
performed according to the manufacturer's instructions with Formazin standards. This was done each
time the instrument was calibrated with Formazin suspensions thereby standardizing the Gelex cells to
that instrument for that period. When the instrument is recalibrated, the Gelex cells are also
recalibrated. Additional secondary standards of 0.1, 0.5, 1.0 and 3.0 NTU were prepared from fresh
Formazin stock, or purchased as a standard from Hach. These standards were referenced daily. While
the comparison of the readings to the standards at 0.5, 1.0 and 3.0 NTU were relatively stable, the
reference of 0.1 NTU was somewhat ambiguous as it is at or near the limit of detection for this
instrument.

4.5.5 A nalytical Laboratory QA/QC

QA/QC procedures for laboratory analyses were based on SM, 19th Ed. (APHA, 1995) and Methods
for Chemical Analysis of Water and Wastes (EPA, 1995).

The QA/QC for the field collection of water samples using EPA Method 1623 was achieved throughout
the pilot testing. All samples collected using the Gelman filter cartridges were maintained at 4°C prior to

66


-------
and during shipping to BioVir Laboratories where the filters were processed. All samples were
processed to completion within 72 hours of sample collection as stated in EPA Method 1623.

Calibration results of the analytical instrumentation used to conduct the analyses on effluent water is
recorded and kept on file at Spectrum Labs, Inc. QA/QC procedures and documentation pertinent to
this verification test are on file at Spectrum Laboratories, and Cartwright, Olsen & Associates, LLC.

It was noted that the Spectrum QC data documentation lacked the reviewer's initials and the date of
review. The written response from Spectrum regarding this issue indicated that they believed that the
review occurred, however, the documents lack the notation of the review. A review of the QC data
and results of analytical instrumentation indicate that adequate controls were in place to render the data
obtained acceptable.

67


-------
Chapter 5
References

Adin, Anner and Rebhum, Menahem. A model to predict concentration and headloss profiles in
filtration. Journal AWWA, 444-453 (1977).

Amirtharajah, A. "Some theoretical and conceptual views of filtration", American Water Works
Association Seminar Proceedings, American Water Works Association, Denver CO, 21-26, 1988.

ANSI/AWWA B100-89, AWWA Standard for Filtering Material, American Water Works
Association, Denver, CO, 1989.

American Public Health Association, American Water Works Association, Water Environmental
Federation, Standard Methods for the Examination of Water and Wastewater, 19th Edition,
APHA, AWWA, WEF, Washington D C, 1995.

American Water Works Association, Operational Control of Coagulation and Filtration
Processes, Manual of Water Supply Practices M37, American Water Works Association, Denver,
CO, 1992.

Arrowood, M.J. and C.R. Sterling. Isolation of Cryptosporidium oocysts and sporozoites using
discontinuous sucrose and siopycnic gradients. Journal of Parasitology 73: 314-319 (1987).

Arrowood, M.J. and K, Donaldson. Improved purification methods for calf-derived Cryptosporidium
parvum oocysts using discontinuous sucrose and cesium gradients. Journal of Peukaryotic
Microbiology 43: 89S (1996).

Barnes, I. Field Measurement of Alkalinity and pH, Geological Survey Water-Supply Paper 1535-
H, 1964.

Clancy, J.L., McKelvey G., Latimer, G., and Shramko, J. "Performance of the Kinetico Pressure
Filtration System in a Pilot Plant Challenge Using Giardia lamblia Cysts and Cryptosporidium
Oocysts", Paper presented at the American Water Works Association Annual Conference, June
1993.

Cleasby, J.L. Filtration in Water Quality and Treatment, Fourth Edition, by American Water
Works Association, 455-560, 1990.

Cleasby, J.L., Logsdon G. S. Granular Bed and Precoat Filtration in Water Quality and Treatment,
Fifth Edition. Journal A WWA, 8.1-8.99, 1999.

Cleasby, J. L., Williamson, M.M., & Bauman, E.R. Effect of Filtration Rate Changes on Quality,
American Water Works Association, 869-880, 1963.

68


-------
Cleasby, J.L. Approaches to filterability index for granular filters, American Water Works
Association, 372-381, Aug. 1969.

Cushen, A.D., Kugrens, P., and Hendricks D.W. Zeta Potentials of Selected Algae,
Cryptosporidium oocysts, Giardia cysts, Environmental Engineering Technical Report 53-5204-96-3,
Dept. of Civil Engineering, Colorado State University, 1996.

Drozd, C. and Schwartzbrod J. Hydrophobic and Electrostatic Cell Surface Properties of
Cryptosporidium parvum. Applied and Environmental Microbiology, 62 (4): 1227-1232 (1996).

Frey, M.N. et.al., "A Synthesis Report of Cryptosporidium." Paper presented at the American Water
Works Association Annual Conference Presentation, Atlanta, Georgia, June 18, 1997.

Great Lakes-Upper Mississippi River Board of State Public Health and Environmental Managers,
Recommended Standards for Water Works, (Commonly referred to as the Ten State's Standards)
Health Education Services, Albany NY, 1992.

Hancock, C.M, Ward, J.V., Hancock, K.W., Klonicki P.T. and Sturbaum C.D. Assessing Plant
Performance Using MP A, Journal AWWA, 12:88:24-34, (1996).

Harter, T. Wagner, S. and Atwill, E.R. Colloid Transport and Filtration of Cryptosporidium parvum in
Sandy Soils and Aquifer Sediments. Environmental Science and Technology 24 (1): 62-70 (2000).

Kiminski, J.C. Correspondence in New England Journal of Medicine 331 (22): 1529-1530, (1994).

LeChevallier, M.W. et al. Giardia and Cryptosporidium spp. in Filtered Drinking Water Supplies.
Applied and Environmental Microbiology. 57 (9): 2617-2621 (1991).

MacKenzie, W.R. et al. A Massive Outbreak in Milwaukee of Cryptosporidium Infection Transmitted
through the Public Water Supply. New England Journal of Medicine 331 (3): 161-167 (1994).

McTigue, N. E., and MacPhee, M.J., Engineering Pilot Plant Studies for Assessing Pathogen Removal
Treatment: Design and Operational Considerations. Environmental Engineering and Technology.
Newport News, Virginia.

Medema, G.J, F.M Schets, P.F.M. Teunis, and A.H. Havelaar, Sedimentation of Free and Attached
Cryptosporidium Oocysts and Giardia Cysts in Water, Applied and Environmental Microbiology.
64(11): 4460-4466 (1998)

Ongerth, J.E., and Proctor Precoraro, J. Electrophoretic Mobility of Cryptosporidium oocysts and
Giardia cysts, Journal of Environmental Engineering. 122, (3): (ASCE) 228-231 (1996).

69


-------
U.S. Environmental Protection Agency, Method 1622. Cryptosporidium in water by
Filtration/IMS/FA, Draft of December 1997, EPA-821-R-97-023. Cincinnati, OH: U.S. Environmental
Protection Agency, 1998.

U.S. Environmental Protection Agency, Method 1623. Cryptosporidium and (jiardia in water by
Filtration/IMS/FA, EPA-821-R-99-006. Cincinnati, OH: U.S. Environmental Protection Agency,
1999.

U.S. Environmental Protection Agency, National Primary Drinking Water Regulations: Interim
Enhanced Surface Water Treatment Rule Notice of Data Availability, 62 Fed. Reg. 59486-59577
(1997) (to be codified at 40 C.F.R. pt 141, 142)(proposed).

U.S. Environmental Protection Agency/NSF International. ETV Protocol: Protocol for Equipment
Verification Testing for Physical Removal of Microbiological and Particulate Contaminants,
EPA/NSF, April 20, 1998.

U.S. Environmental Protection Agency/NSF International. EPA Test Plan: NSF Equipment
Verification Testing Plan, Backwashable Depth Filtration for the Removal of Microbiological
and Particulate Contaminants, EPA/NSF, April 20, 1998.

U.S. Environmental Protection Agency, Office of Drinking Water, Guidance Manual for Compliance
with the Filtration and Disinfection Requirements for Public Water System Using Surface Water
Sources, EPA No. 68-1-6989, U.S. EPA, Washington, D.C., March 1991b.

"U.S. Geological Survey National Water-Quality Assessment Program" Upper Mississippi River
Basin Study Unit, July 12, 1997, http:/www.cr.usgs.gov/umis/descrip.html, (November 10, 1999).

Watanabe, M.E. New Cryptosporidium Testing Methods, Environmental Science and Technology.
30(12): 532A-535A (1996).

70


-------