2018-19 NRSA Fish Fillet Tissue Data Dictionary for Mercury, PCBs, and PFAS

October 2022

The U.S. Environmental Protection Agency (EPA) Office of Science and Technology (OST) within the Office of
Water (OW) is providing the fish fillet tissue results from the 2018-19 National Rivers and Streams Assessment
(NRSA). The specific chemical analyses include:

•	Mercury (total)

•	Poly chlorinated biphenyls (PCBs) (all 209 congeners)

•	Per- and polyfluoroalkyl substances (PFAS) (33 compounds)

This file includes the "data dictionary" for each type of chemical contaminant analysis. The field names and
descriptions for the analytical results are similar for each type of chemical analysis, but results from some analyses
include additional information that may not apply to all analysis types. OST is also providing information on the
fish composite samples collected during the study and used to prepare the fillet tissue samples that were analyzed.
The fish sample information for each contaminant data file is identical, so only one version of the dictionary for the
sample information is provided after the dictionary for the results for each type of contaminant analysis.

Results Tabs for

IMcrcurv, PCBs, and PFAS

Field Name

Description

EPA Region
(Column A)

The EPA Region in which the fish composite sample was collected.

State

(Column B)

U.S. Postal Service 2-letter abbreviation for the state in which the fish composite sample was
collected.

Site ID
(Column C)

The identifier assigned by EPA to each river sampling site.

EPA Sample ID
(Column D)

Unique 6-digit number assigned by EPA to each fish composite sample.

Tissue Type
(Column E)

The type of fish tissue used to prepare samples for analysis. For the 2018-19 NRSA Fish Tissue
Study, fillet tissue samples were analyzed for all the chemical contaminants.

% Lipids
(Column F)

The percentage of lipids in the fillet tissue sample. (Please note that the lipid results were not
used to normalize the mercury, PCB, or PFAS results.)



An identifier for the analytical method used for each chemical. For the mercury and PCB results,
the identifiers refer to the following standardized EPA methods:

EPA Method 163 IE. Mercury in Water bv Oxidation, Purse and Trap, and Cold Vapor Atomic
Fluorescence Spectrometry, EPA-821-R-02-019, August 2002.

Method
(Column G)

EPA Method 1668C. Chlorinated Biphenvl Conveners in Water, Soil, Sediment, Biosolids, and
Tissue by HRGC/HRMS, EPA-820-R-10-005, April 2010.

For the PFAS results, there were no EPA methods for analysis of fish tissue at the time of the
study, so fillet samples were analyzed by an in-house procedure developed by the commercial
laboratory, utilizing liquid chromatography with tandem mass spectrometric detection
(LC/MS/MS).



Common name or abbreviation for the chemical.

Chemical
(Column H)

For PCBs, the abbreviation "PCB" is followed by the congener number (i.e., "PCB-7"). It is not
practical to completely separate all 209 PCB congeners from one another during analysis, so
congeners that elute from the gas chromatograph together are listed with a forward slash between
each congener, in increasing congener number order, e.g., PCB-12/PCB-13. "Total PCBs" is the
name given to the sum of the results for all 209 of the congeners (which includes the coeluting
congener groups) reported in the fillet sample. This value was calculated by OST, using zero for
any congener result that was "not detected" at the method detection limit.

For PFAS, the chemical names are those of the anion form of the chemical (e.g., the "ate" form).



Chemical Abstracts Service (CAS) Registry Number assigned by CAS to the chemical.

CAS Number
(Column I)

CAS Numbers do not exist for the groups of coeluting PCB congeners.

For PFAS, this is the CAS Number of the parent acid or amide form, because the anions do not
have separate CAS Numbers.

1


-------
2018-19 NRSA Fish Fillet Tissue Data Dictionary for Mercury, PCBs, and PFAS

October 2022

Results Tabs for

Mercury, PCBs, and PFAS

Field Name

Description



Concentration of the chemical, if detected. If this field is blank, then the chemical was not
detected in the fillet sample. In order to accommodate the range of concentrations in these
samples, all the results are presented with the same number of decimal places for a chemical
(mercury) or chemical class (PCBs and PFAS).

Amount
(Column J)

For mercury, the amount field is presented to 1 decimal place.

For the PCBs, the amount fields are presented to 5 decimal places.

For PFAS, the amount field is presented to 3 decimal places.

However, these results have at most 3 significant figures, regardless of the number of decimal
places (for example, a PFAS value of 19.000 does not imply 5 significant figures).

MDL

(Column K)

The nominal method detection limit (MDL) for the chemical, based on the procedure in 40 CFR
part 136, not adjusted for actual sample size, in the units shown in the Units columns.

For mercury, MDLs are reported to 2 decimal places.

For PCBs, MDLs are reported to 5 decimal places.

For PFAS, MDLs are reported to 3 decimal places.

QL

(Column L)

The nominal quantitation limit (QL) or "Minimum Level" for the chemical, based on the lowest
calibration standard analyzed, not adjusted for sample size, in the units shown in the Units
columns.

Unit 1

(Column M)

The weight/weight units of nanograms per gram or ng/g (see Unit 2 description below for
equivalent unit).

Unit 2
(Column N)

The "parts per billion" notation ppb, which is equivalent to ng/g.



The data qualifier flag(s) applied by the laboratory. For mercury, no lab qualifier flags were
required.

Lab Qualifier
Flag

(Column 0)

For the other chemicals, the following flags were used, either singly or in combination:

U = Not detected

B = Chemical also present in the method blank
C = Chemical is a coeluting group of congeners
D = Result is from a diluted analysis

G = Evidence of a disturbance with the lock-mass used during the analysis
H = Estimated concentration (for reason not covered by "J")

J = Estimated value (between the MDL and QL values)

K = Ion abundance ratio is outside of the acceptance limits, but the chemical meets all the other

identification criteria
NQ = Not quantified because the associated labeled compound was not detected

SCC Code

Qualifiers applied by the Sample Control Center staff at CSRA (EPA analytical support
contractor) during data validation. For mercury, no SCC codes were required.

(Column P)

The individual SCC codes applied to the other results (PCBs and PFAS) are identified and
defined in the table of SCC codes below.

Comments
(Column Q)

A text translation of the SCC code combinations applied to each result. For mercury, no SCC
codes were required, so no comments were needed.

Sort Order
(Column R)

Applies only to PCBs and PFAS. A field used to sort the chemical names in a consistent order
within each chemical group.

For PCBs, the values in this field range from 1 to 160.

For PFAS, the values in this field range from 1 to 33.

2


-------
2018-19 NRSA Fish Fillet Tissue Data Dictionary for Mercury, PCBs, and PFAS

October 2022

Sample Information Tab for All Chemicals

Field Name

Description

EPA Region
(Column A)

The EPA Region in which the fish composite sample was collected.

State

(Column B)

U.S. Postal Service 2-letter abbreviation for the state in which the fish composite sample was
collected.

Site ID
(Column C)

The identifier assigned by EPA to each river sampling site.

River Name
(Column D)

The name of the river from which the fish composite sample was collected.

Latitude
(Column E)

Latitude, in decimal format, to 5 decimal places.

Longitude
(Column F)

Longitude, in decimal format, to 5 decimal places.

Site Type
(Column G)

Urban, Non-urban designation (based on Census Bureau GIS data).

Stream Order
(Column H)

A measure of stream position within a drainage network system. Streams that have no
tributaries flowing into them are called first-order streams. Stream orders in this study range
from fifth-order (5) to greater than eighth-order (8+), which are defined as rivers for this
study.

Sample Collection
Date

(Column I)

Sample collection date, in MM/DD/YYYY format.

EPA Sample ID
(Column J)

Unique 6-digit number assigned by EPA to each fish composite sample.

Specimen ID
(Column K)

The 6-digit EPA Sample ID, followed by a decimal point and a value between 1 and 10. The
decimal portion identifies the number assigned to the individual fish specimen in the
composite sample.

Spec Sort
(Column L)

A specimen sorting field designed to account for the fact that samples with more than 9
specimens do not sort properly (i.e., XX. 10 sorts before XX.2).

Family
(Column M)

Latin name of the Family based on Nelson el al. (2004). (see full citation directly below)

Species - Scientific
Name

(Column N)

Latin name (Genus and species) based on Nelson et al. (2004), Common and Scientific Names
of Fishes from the United States, Canada, and Mexico, Sixth Edition.

Species - Common
Name

(Column 0)

Generally accepted common name based on Nelson et al. (2004).

Total Length (mm)
(Column P)

Length of each individual fish specimen in millimeters (mm).

Included in
composite?
(Column Q)

This field indicates if the fish specimen was included in the fillet tissue sample for analysis or
not. The options are either "Yes" or "No" and the rationale is explained in the "Fillet Sample
Preparation Instructions" field to the far right.

Predator or Bottom
Dweller
(Column R)

Classification of the fish species as either:
P = Predator species, or
BD = Bottom-dweller species

Composite
Classification
(Column S)

Routine vs. Non-routine composite, based on the fish composite sample criteria specified in
the human health fish sampling procedures and identified online in the 2018-19 NRSA Fish
Tissue Study web page.

Deviation
(Column T)

For non-routine composites, the nature of the deviation from the criteria (e.g., number of fish,
fish length, or both).

Fillet Sample
Preparation
Instructions
(Column U)

Instructions from EPA/OW/OST to the sample preparation laboratory regarding which
specimens to include in the fillet composite sample for analysis, based on specimen length,
species, etc.

3


-------
2018-19 NRSA Fish Fillet Tissue Data Dictionary for Mercury, PCBs, and PFAS

October 2022

Individual SCC Codes Applied to the 2018-19 NRSA Fish Tissue Study Results

SCC Code

Comments

Implication

B, RMAX

Blank Contamination,
Result is a Maximum
Value

Blank contamination was observed, and the target chemical was reported in
the sample at a concentration between 5 and 10 times higher than the blank
value. The result was considered to be of acceptable quality, but data users
are cautioned that it may be a maximum value due to possible influence of
contamination.

B, RNAF

Blank Contamination,
Result is Not Affected

Blank contamination was present but was not considered to adversely
impact the sample result. The presence of the chemical in the blank is not
considered to adversely affect the data in cases where the sample results are
more than 10 times the associated blank results or where the chemical is
not detected in associated samples.

B, RNON

Blank Contamination,
Result Reported as a
Non-detect

When the sample result is less than five times the blank result, there are no
means by which to ascertain whether or not the presence of the chemical
may be attributed to contamination. Therefore, the result is reported in the
database as a non-detect at the MDL, adjusted for sample size and dilution.

HIAR, J

High Ion Abundance
Ratio, Estimated

Each chemical is identified and quantified based on the instrumental
response for two specific ions and the ratio of those two ions was above the
upper acceptance limit, suggesting a potential interference that may affect
the sample result. Therefore, the result also is flagged as an estimated
value.

HLBL

High Labeled
Compound Recovery

The labeled analog of the target chemical was recovered above acceptance
criteria, suggesting the possible presence of matrix interferences. Isolated
instances of high recovery are not uncommon, and patterns across multiple
samples are more of a concern. If the chemical was not detected in a field
sample, there is no concern and the RNAF is added to the HLBL flag.

HLBL, J

High Labeled
Compound Recovery,
Estimated

The labeled analog of the target chemical was recovered above acceptance
criteria, suggesting the possible presence of matrix interferences. Isolated
instances of high recovery are not uncommon, and patterns across multiple
samples are more of a concern.

HLBL,
RNAF

High Labeled
Compound Recovery,
Result is Not Affected

The labeled analog of the target chemical was recovered above acceptance
criteria, suggesting the possible presence of matrix interferences. Isolated
instances of high recovery are not uncommon, and patterns across multiple
samples are more of a concern. If the chemical was not detected in a field
sample, there is no concern and the RNAF is added to the HLBL flag.

HLCS

High Lab Control
Sample Recovery

The lab control sample (LCS) was a clean reference matrix. If recovery in
the

LCS was high, there may be a high bias for that chemical.

HLCS,
RNAF

High Lab Control
Sample Recovery,
Result is Not Affected

The recovery in the LCS was high, but the chemical was not detected in the
associated fillet tissue sample, so there was no high bias concern and the
RNAF flag was applied.

HRPD, J

High RPD, Estimated

The relative percent difference (RPD) between the results in the parent
sample and the laboratory duplicate is above the acceptance limit. This may
be due to inhomogeneity in the bulk sample or analytical variability. When
high RPD was observed for a chemical, all the detected results for that
chemical in any of the samples in the batch with the duplicate sample were
qualified as estimated values.

HRPD,
RNAF

High RPD, Result is Not
Affected

The relative percent difference (RPD) between the results in the parent
sample and the laboratory duplicate is above the acceptance limit. This may
be due to inhomogeneity in the bulk sample or analytical variability.
However, when high RPD was observed for an chemical, the non-detected
results for that chemical were not affected, and the RNAF flag was applied.

4


-------
2018-19 NRSA Fish Fillet Tissue Data Dictionary for Mercury, PCBs, and PFAS

October 2022

Individual SCC Codes Applied to the 2018-19 NRSA Fish Tissue Study Results

SCC Code

Comments

Implication

HVER, J

High CALVER,
Estimated

The results for the calibration verification associated with the chemical
were above the acceptance limit, suggesting a possible high bias. Detected
chemicals also are considered estimated values.

J

Estimated

When applied alone, this code indicates that the result is at or above the
MDL, but below the QL. This flag also may be applied in conjunction with
other flags to indicate the potential for greater uncertainty.

LIAR, J

Low Ion Abundance
Ratio, Estimated

Each chemical is identified and quantified based on the instrumental
response for two specific ions and the ratio of those two ions was below the
lower acceptance limit, suggesting a potential interference that may lower
the sample result. Therefore, the result also is flagged as an estimated
value.

LLBL

Low Labeled
Compound Recovery

The labeled analog of the target chemical was recovered below acceptance
criteria, suggesting the possible presence of matrix interferences or
incomplete recovery of both the labeled compound and target chemical
during the extract cleanup processes used in the analytical procedure. The
use of isotope dilution quantitation automatically corrects the results for the
target chemical, even when the labeled compound recovery is below
expectations. This flag is applied when the chemical associated with the
labeled analog is not detected in the sample.

LLBL, J

Low Labeled
Compound Recovery,
Estimated

The labeled analog of the target chemical was recovered below acceptance
criteria, suggesting the possible presence of matrix interferences or
incomplete recovery of both the labeled compound and target chemical
during the extract cleanup processes used in the analytical procedure. The
use of isotope dilution quantitation automatically corrects the results for the
target chemical, even when the labeled compound recovery is below
expectations. When the chemical associated with the labeled analog is
detected in the sample, the result is also flagged as an estimated value.

LLCS

Low LCS result

The lab control sample (LCS) was a clean reference matrix. If recovery in
the LCS was low, there may be a low bias for that chemical. When low
LCS recovery was observed for a chemical, the results for that chemical
were qualified in all of the samples in the batch with the LCS.

LMI, J

Lock mass interference,
Estimated

There was an interference with the lock mass monitored by the high-
resolution mass spectrometer to ensure accurate mass identification. That
interference may affect the quantification of the chemical and the result is
flagged as an estimated value.

LMI, RNAF

Lock mass interference,
Result is Not Affected

There was an interference with the lock mass monitored by the high-
resolution mass spectrometer to ensure accurate mass identification. That
interference may affect the quantification of the chemical, but when the
chemical was not detected, the result is not affected.

LND, NQ

Labeled compound Not
Detected, Not
Quantified

The labeled compound associated with this chemical could not be detected
due to interferences or other causes. Therefore, the chemical could not be
quantified by isotope dilution and was reported as a non-detect at the MDL.

NPD, RNON

No definitive peak
shoulder for coeluter,
Result Reported as Non-
detect

Coeluting PCB congeners cannot be completely separated by the gas
chromatograph and one or more of the coeluting congeners will appear as a
"shoulder" on the peak for the other congeners. If such a shoulder is not
present, the chemical has not been identified and the result is reported as
not detected.

RRT, J

RRT outside of window,
Estimated

The relative retention time of the chemical shifted outside of its expected
window and as a result, the quantification of the chemical may be affected,
and the result is considered an estimated value.

5


-------
2018-19 NRSA Fish Fillet Tissue Data Dictionary for Mercury, PCBs, and PFAS

October 2022

Individual SCC Codes Applied to the 2018-19 NRSA Fish Tissue Study Results

SCC Code

Comments

Implication

RTI, RMAX

Retention Time
Interference; Result is a
Maximum Value

There was an interference apparent at the retention time of the chemical.
Although it did not prevent the identification of the chemical, it likely
affected the quantitative result, and the result is considered a maximum
value.

Note: Commas are used to separate related parts of a single code (e.g., "B, RNON" is considered one code), while
semicolons are used to separate different codes (e.g., "B, RNAF; J" is the combination of two codes).

6


-------