ERT Data Dictionary

Wednesday, May 04, 2016
10:17:43 AM

Table Name: tbIRunHeader
Table Description: Instrumental Methods Header Data

Field Name

Field Description

Field Type

Size

Key

Required

PercCOHDR

This is the carbon monoxide percentage which
defaults to zero (0). ... not used for method 5 or 202

Double

8





NozzleCkPost

This is a pull-down selection for nozzle inspections
for dents, nicks, etc. This field is present only on the
single train "Header Data" tab.

Text

20





Impinit2

This is the initial volume or weight of impinger
number 2. The ERT uses the value in this field in the
calculation to produce the sum of the differences of
all of the impingers and populate this value into the
VIcHDR field.

Double

8





Impinitl

This is the initial volume or weight of impinger
number 1. The ERT uses the value in this field in the
calculation to produce the sum of the differences of
all of the impingers and populate this value into the
VIcHDR field.

Double

8





FcHDR

The value "Fc" is the ratio of the theoretical carbon
dioxide produced during combustion to the higher
heating value of the fuel combusted. With carbon
dioxide, the emission rate in Ib/MMBtu can be
calculated from wet or dry emissions concentration.

Long Integer

4





FwHDR

The value "Fw" is the ratio of the quantity of wet
effluent gas generated by combustion to the gross
calorific value of the fuel. With wet oxygen and
moisture concentration, the emission rate in
Ib/MMBtu can be calculated.

Long Integer

4





RunStatus

added 9/28/05 - Accepted/Rejected

Text

20





Impinit4

This is the initial volume or weight of impinger
number 4. The ERT uses the value in this field in the
calculation to produce the sum of the differences of
all of the impingers and populate this value into the
VIcHDR field.

Double

8





FuelType

This is a pull-down selection of the Fuel Type which
also populates the three F-factor fields FdHDR,
FwHDR and FcHDR with the values presented in
Table 19-2 of EPA Method 19. In addition, the user
may select "Override" and enter fuel specific F-
factors.

Text

25





Page 1 of 54


-------
Table Name: tbIRunHeader
Table Description: Instrumental Methods Header Data

Field Name

Field Description

Field Type

Size

Key

Required

Impinit5

This is the initial volume or weight of impinger
number 5. The ERT uses the value in this field in the
calculation to produce the sum of the differences of
all of the impingers and populate this value into the
VIcHDR field.

Double

8





PstdHDR

This is the standard pressure which defaults to EPA
standard of 29.92 inches of mercury. When the test
method performed requires the use of a different
standard pressure, the user can change the "29.92"
in this field to the pressure specified.

Double

8





tstdHDR

This is the standard temperature which defaults to
EPA standard of 68 degrees F. When the test
method performed requires the use of a different
standard temperature, the user can change the "68"
in this field to the temperature specified.

Double

8





Location

This is the unique sampling location name, such as
inlet, stack, ESP inlet, scrubber outlet, etc. which
was provided during the Test Plan preparation.

Text

50





Personnel

Not Used. This is left in for compatibility with old
project data sets.

Text

50





StackTCCKPost

This is a pull-down selection for the post-test results
of the thermocouple check, as applicable. Paired
sampling trains also requires the recording of
sorbent trap and probe temperatures, there are
checks for these thermocouples.

Text

25





StackTCCKMid

This is a pull-down selection for the mid-test results
of the thermocouple check, as applicable. Paired
sampling trains also require the recording of
sorbent trap and probe temperatures, there are
checks for these thermocouples.

Text

25





StackTCCKPre

This is a pull-down selection for the pre-test results
of the thermocouple check, as applicable. Paired
sampling trains also require the recording of
sorbent trap and probe temperatures, there are
checks for these thermocouples.

Text

20





FdHDR

The value "Fd" is the ratio of the quantity of dry
effluent gas generated by combustion to the gross
calorific value of the fuel. With oxygen
concentration, the emission rate in Ib/MMBtu can
be calculated from the dry pollutant emissions
concentration.

Long Integer

4





Page 2 of 54


-------
Table Name: tbIRunHeader
Table Description: Instrumental Methods Header Data

Field Name

Field Description

Field Type

Size

Key

Required

Impfin6

This is the final volume or weight of impinger
number 6 determined after the test. The ERT uses
the value in this field in the calculation to produce
the sum of the differences of all of the impingers
and populate this value into the VIcHDR field.

Double

8





RunNumber

PK- This is for the Run Number of the test. This
number is assigned by the test company. Generally,
the run number is an integer value which indicates
the sequence order for the performance of the test
method for the location.

Text

50

Primary



ProcRunID

This is the run id of the process parameter
associatied with the same time the test was
performed. The user uses a drop down menu to
select the process parameter which is stored in the
"Process ParamID" field of table
"tbIProcessRunData".

Text

75





PercC02Runld

This is the run id of a Method 3A test for C02 if the
users selects the C02 run from the pull down menu,
(if pulled from that method)

Text

75





Probe

This is the sample probe and or Pitot equipment
identification number. The Pitot is the piece of
hardware used to measure the velocity pressure of
the stack gas. The ID is necessary for calibration
documentation purposes.

Text

50





Ambient

Ambient Temperature in degrees F. The ambient
temperature field is present only on the single train
"Header Data" tab.

Long Integer

4





Mansense

This is the sensitivity of the micromanometer if one
was used. The units for this field is inches of water
column.

Double

8





Impinit3

This is the initial volume or weight of impinger
number 3. The ERT uses the value in this field in the
calculation to produce the sum of the differences of
all of the impingers and populate this value into the
VIcHDR field.

Double

8





Silicafin

This is the final weight of impinger containing Silica
Gel determined after the test. The ERT uses the
value in this field in the calculation to produce the
sum of the differences of all of the impingers and
populate this value into the VIcHDR field.

Double

8





Perc02Runld

This is the run id of a Method 3A test for 02 if the
users selects the 02 run from the pull down menu,
(if pulled from that method)

Text

75





Page 3 of 54


-------
Table Name: tbIRunHeader
Table Description: Instrumental Methods Header Data

Field Name

Field Description

Field Type

Size

Key

Required

Impfin5

This is the final volume or weight of impinger
number 5 determined after the test. The ERT uses
the value in this field in the calculation to produce
the sum of the differences of all of the impingers
and populate this value into the VIcHDR field.

Double

8





Impfin4

This is the final volume or weight of impinger
number 4 determined after the test. The ERT uses
the value in this field in the calculation to produce
the sum of the differences of all of the impingers
and populate this value into the VIcHDR field.

Double

8





Impfin3

This is the final volume or weight of impinger
number 3 determined after the test. The ERT uses
the value in this field in the calculation to produce
the sum of the differences of all of the impingers
and populate this value into the VIcHDR field.

Double

8





Impfin2

This is the final volume or weight of impinger
number 2 determined after the test. The ERT uses
the value in this field in the calculation to produce
the sum of the differences of all of the impingers
and populate this value into the VIcHDR field.

Double

8





Impfinl

This is the final volume or weight of impinger
number 1 determined after the test. The ERT uses
the value in this field in the calculation to produce
the sum of the differences of all of the impingers
and populate this value into the VIcHDR field.

Double

8





Silicainit

This is the initial weight of impinger containing Silica
Gel. The ERT uses the value in this field in the
calculation to produce the sum of the differences of
all of the impingers and populate this value into the
VIcHDR field.

Double

8





Impinit6

This is the initial volume or weight of impinger
number 6. The ERT uses the value in this field in the
calculation to produce the sum of the differences of
all of the impingers and populate this value into the
VIcHDR field.

Double

8





Manused

This is the identification number of the
micromanometer if used.

Text

50





FilterNum2

This is the specific identifier for the second filter
used for the test run if used. The value provided is
the filter's unique identification number and is used
for associating laboratory analyses with a specific
test.

Text

20





Pitot

This is the Pitot tube ID. Used with the spreadsheet
import

Text

25





Page 4 of 54


-------
Table Name: tbIRunHeader
Table Description: Instrumental Methods Header Data

Field Name

Field Description

Field Type

Size

Key

Required

TCReadOut

This is the Thermocouple read out. Used with the
spreadsheet import

Text

25





MeterBox

This is the identification number of the Dry Gas
Meter. The dry gas meter is the piece of hardware
responsible for quantifying the volume of gas
passing through the meter. The ID is necessary for
calibration documentation purposes.

Text

25





SampBox

This is the ID of the sample box. Used with the
spreadsheet import.

Text

25





TedlarBag

This is the ID of a Tedlar bag, if used. The Tedlar bag
ID is present only on the "Single Train" header tab.

Text

25





Umbical

This is the identificatin number of the sample
transport line either from the sample probe to the
filter and impinger box or from the exit of the
impingers to the Meter Box console. The Umbilical
ID is present only on the "Single Train" header tab.

Text

25





Nozzle

The nozzle ID is necessary for calibration
documentation purposes. Method 5 requires the
measurement of the diameter of each probe nozzle
before use and a permanent unique identifier. The
Nozzle ID is present only on the "Single Train"
header tab.

Text

25





FilterNum3

This is the specific identifier for the third filter used
for the test run if used. The value provided is the
filter's unique identification number and is used for
associating laboratory analyses with a specific test.

Text

20





OrasatPump

This is the ID of the pump used for filling a Tedlar
bag, for example. The Orsat Pump ID is present only
on the "Single Train" header tab.

Text

25





FilterNuml

This is the specific identifier for the first filter used
for the test run. The value provided is the filter's
unique identification number and is used for
associating laboratory analyses with a specific test.

Text

20





PgHDR

This is the static pressure (inches of water), of the
sampling location. Some screens show Pstatic or Pg.
Static pressure is typically measured with a Pitot
tube. The value is the difference between the stack
and local atmospheric pressure.

Double

8





Page 5 of 54


-------
Table Name: tbIRunHeader
Table Description: Instrumental Methods Header Data

Field Name

Field Description

Field Type

Size

Key

Required

PbHDR

The barometric pressure of the sampling location.
The pressure is reported in units of inches of
mercury at the sampling platform. User obtained
weather service pressures are adjusted for the
differences in pressure due to differences in
elevation.

Double

8





Method

PK- The field identifies the method used to measure
the analyte emissions. The test method was one of
the user selected isokinetic or manual sampling
methods which were entered in Item 2a of the Test
Plan.

Text

20

Primary



RunDate

PK- This is the date that the test was performaned.

Date/Time

8

Primary



JobNumber

This is the contractor's internal job or project
number. Used with the spreadsheet import

Text

25





NozzleCkMid

This is a pull-down selection for nozzle inspections
for dents, nicks, etc. This field is present only on the
single train "Header Data" tab.

Text

20





ReagBox

This is the identification number of the Control
Console. The control console is the combination of
the dry gas meter, pumps, temperature controllers,
manometers, etc. The ID is necessary for calibration
documentation purposes.

Text

25





LeakRtPost

The post-test sampling train leak check rate. The
post-test leak rate must be less than or equal to 4
percent of the average sampling rate or 0.02 acfm
whichever is less.

Double

8





NozzleCkPre

This is a pull-down selection for nozzle inspections
for dents, nicks, etc. This field is present only on the
single train "Header Data" tab.

Text

20





PitotCkPost

This is a pull-down selection for the mandatory post-
test leak check result. This is a pass or fail
assessment against the specifications in EPA
Method 2.

Text

20





StackTC

This is the ID of the thermocouple device used for
monitoring the stack gas temperature. The ID is
necessary for calibration documentation purposes.

Text

25





PitotCkPre

This is a pull-down selection for the pre-test leak
check result, if performed. This is a pass or fail
assessment against the specifications in EPA
Method 2.

Text

20





Page 6 of 54


-------
Table Name: tbIRunHeader
Table Description: Instrumental Methods Header Data

Field Name

Field Description

Field Type

Size

Key

Required

VIcHDR

This is the sum of the volume or weight of the
moisture condensed in each of the impingers to the
nearest milliliter. In the ERT application this field is
shown as "Vic".

Double

8





LeakRtPre

The pre-test sampling train leak check rate. The
post-test leak rate must be less than or equal to 4
percent of the initial sampling rate or 0.02 acfm
whichever is less.

Double

8





FinalDGM

For single sampling trains, this is the total volume
recorded by the dry gas meter (DGM) during all leak
checks performed between the pre test and post
test leak checks. This volume is subtracted from the
total sample volume recorded for the test run.

Double

8





InitDGM

This is the initial volume or the dry gas meter prior
to any of the leak checks conducted between the
pre test and post test leak checks. This value is set
at 0.

Double

8





VacCkPost

The vacuum at which the post sampling train leak
checks was performed.

Double

8





Perc02HDR

The oxygen percent of the gas stream tested. The
pull-down to the right of the field for the 02
concentration provides access to the results of
instrumental measurements of 02.

Double

8





PercC02HDR

The carbon dioxide percent of the gas stream
tested. The pull-down to the right of the field for the
C02 concentration provides access to the results of
instrumental measurements of C02.

Double

8





DnHDR

This is the nozzle diameter. The nozzle diameter is
measured in inches.

Double

8





CpHDR

This is the Pitot tube coefficient which is
dimensionless. The Pitot tube coefficient for an S-
type Pitot can range from 0.80 to 0.88 but is usually
between 0.84 and 0.864. The Cp for a standard
Pitot is 0.99.

Double

8





DH@HDR

Delta H @ (AH@) is the orifice pressure differential
in inches of H20 of an isokinetic sampling train
meterbox (such as used for Method 5 sampling) that
correlates to 0.75 cfm at 5282R and 29.92 in Hg.

Double

8





Page 7 of 54


-------
Table Name: tbIRunHeader
Table Description: Instrumental Methods Header Data

Field Name

Field Description

Field Type

Size

Key

Required

YHDR

This is the dry gas meter correction coefficient,
gamma, of an isokinetic sampling train meterbox
(such as used for Method 5 sampling). In the
displayed header screen, gamma is shown as "Y".
The units of gamma are dimensionless.

Double

8





VacCkPre

The vacuum at which the pre sampling train leak
checks was performed.

Double

8





PitotCkMid

This is a pull-down selection for the mid-test leak
check result, if performed. This is a pass or fail
assessment against the specifications in EPA
Method 2.

Text

20





Table Name: tbIRunPoints
Table Description: Manual Methods Point Run Data

Field Name

Field Description

Field Type

Size

Key

Required

FinalExitTemp

This is the temperature of sample gas exiting silica
gel impinger, degrees F.

Long Integer

4





PumpVac

This is the vacuum of the sampling pump, measured
in inches mercury.

Double

8





Notes

These are any observations or comments
concerning the test run.

Text

255





Location

RF- This is the unique sampling location name, such
as inlet, stack, ESP inlet, scrubber outlet, etc. which
was provided during the Test Plan preparation.

Text

50



Req.

Point

RF- This is the sampling point label used by the test
company, such as Al, A-l, D-2, etc.

Text

8



Req.

JobNumber

This is the contractors project or job number. Used
with the spreadsheet import.

Text

25





Method

RF- The field identifies the method used to measure
the analyte emissions. The test method was one of
the user selected isokinetic or manual sampling
methods which were entered in Item 2a of the Test
Plan.

Text

20



Req.

FilTempOut

This is the gas temperature exiting the filter box or
compartment, degrees F. Where a sampling
protocol requires the monitoring of two filter
temperatures, this may be used as the exit gas
temperature for the second filter.

Long Integer

4





SampleRate

This is the sampling rate, measured in cubic ft per
min.

Double

8





Page 8 of 54


-------
Table Name: tbIRunPoints
Table Description: Manual Methods Point Run Data

Field Name

Field Description

Field Type

Size

Key

Required

RunNumber

RF- This is for the Run Number of the test. This
number is assigned by the test company. Generally,
the run number is an integer value which indicates
the sequence order for the performance of the test
method for the location.

Text

20



Req.

ImpingTemp

This field is left in for backwards compatibility with
older project data sets.

Double

8





FilTempIn

This is the gas temperature entering the filter box or
compartment, degrees F. Where a sampling
protocol requires the monitoring of two filter
temperatures, this may be used as the exit gas
temperature for the first filter.

Long Integer

4





GasMeter

RF- The dry gas meter volume reading at the
beginning (or end) of the sampling at a point. This
means that the final (or initial) volume reading is
recorded in a row without a point label and no
other recorded point data.

Double

8



Req.

FilterTemp

This field is left in for backwards compatibility with
older project data sets.

Double

8





RunDate

RF- This is the date that the test was performaned.

Date/Time

8



Req.

BeginTime

This is the number of minutes of cumulative
sampling time prior to the beginning of sampling at
the sample point.

Double

8





Clock

This is the actual local clock time at the start of
sampling at a point.

Date/Time

8





Velocity

RF- This is the velocity pressure (Ap) expressed in
inches of water. Values in "AP" are used in the
calculation of isokinetics, average delta p, velocity of
gas stream and actual and standard stack gas flow.

Double

8



Req.

StackTemp

RF- This is the measured stack temperature of the
effluent gas at the sampling point and is expressed
as degrees F. The values in the stack temp are used
in subsequent calculations.

Double

8



Req.

DryGaslnlet

RF- This is the dry gas meter intlet gas temperature,
expressed as degrees F. The values in the dry gas
intlet are used in subsequent calculations.

Double

8



Req.

DryGasOutlet

RF- This is the dry gas meter outlet gas temperature,
expressed as degrees F. The values in the dry gas
outlet are used in subsequent calculations.

Double

8



Req.

Page 9 of 54


-------
Table Name: tbIRunPoints
Table Description: Manual Methods Point Run Data

Field Name

Field Description

Field Type

Size

Key

Required

OrificePresDesired

This is the orifice pressure setting required for
sampling isokinetically, measured by inches water.

Double

8





OrificePresActual

RF- Orifice pressure actually sampled or reached,
measured in inches of water. The values in the
"Orifice Pressure Actual" are used in subsequent
calculations.

Double

8



Req.

ProbeTemp

This is the temperature of the sampling probe,
degrees F.

Double

8





EndTime

RF- This is the number of minutes of cumulative
sampling time at the end of sampling at the sample
point.

Double

8



Req.

Table Name: tbIRunLab
Table Description: Manual Methods Lab Data

Field Name

Field Description

Field Type

Size

Key

Required

Units

This is the mass units, including: gm (grams), mg
(milligrams), ug (micrograms), ng (nanograms) or pg
(picograms).

Text

10





Mass

This is the numerical value of the sample catch
weight reported from the lab. This value may be the
sum of multiple analytical components.

Double

8





Compliance

added 9/28/05 - Yes/No/Indeterminate

Text

20





RunDate

PK- This is the date that the test was performaned.

Date/Time

8

Primary



Flag

Lab qualifier for the sample data. EPA guidance
requests the following flags: BDL (all components
are below detection level); DLL (not all components
are less than the detection level); and ADL (all
components are above the detection level).

Text

50





PlantID

FK- This number provides a link to tbltestplan.

Text

50

Foreign



Method

PK- The field identifies the method used to measure
the analyte emissions. The test method was one of
the user selected isokinetic or manual sampling
methods which were entered in Item 2a of the Test
Plan.

Text

50

Primary



RunNumber

PK- This is for the Run Number of the test. This
number is assigned by the test company. Generally,
the run number is an integer value which indicates
the sequence order for the performance of the test
method for the location.

Text

50

Primary



Page 10 of 54


-------
Table Name: tbIRunLab
Table Description: Manual Methods Lab Data

Field Name

Field Description

Field Type

Size

Key

Required

Location

PK-This is the unique sampling location name, such
as inlet, stack, ESP inlet, scrubber outlet, etc. which
was provided during the Test Plan preparation.

Text

50

Primary



Compound

PK- Analyte name from the Test Plan "Setup"
window.

Text

50

Primary



Comments

Observations or comments. EPA guidance
recommends the reporting of individual
components and laboratory detection level(s) in the
comment field.

Memo

0





Table Name: tblRunHeader30B
Table Description: Method 30 B Header Run Data

Field Name

Field Description

Field Type

Size

Key

Required

tsHDR

This is the calculated stacktemperature based upon
the method selected in TemperatureRunlD. If the
user selected "User Entered" the value is the
number entered.

Double

8





FlowRateRunID

This is the flow rate run identification for the period
corresponding to the time for the emissions test
documented in this record. It is selected from a list
of available flow rate runs by the user. The user also
has the option to select "User Entered".

Text

75





QsdHDR

This is the calculated stack flow in dscfm based upon
the method selected in FlowRateRunID. If the user
selected "User Entered" the value is the number
entered.

Double

8





SorbentT rapCkPostA

This is a pull-down selection for the A train post-test
results of the sorbent trap check, as applicable.

Text

20





SorbentTrapCkPreA

This is a pull-down selection for the A train pre-test
results of the sorbent trap check, as applicable.

Text

20





ProbeCkPostB

This is a pull-down selection for the B train post-test
results of the probe check, as applicable.

Text

20





ProbeCkPostA

This is a pull-down selection for the A train post-test
results of the probe check, as applicable.

Text

20





ProbeCkPreB

This is a pull-down selection for the B train pre-test
results of the probe check, as applicable.

Text

20





ProbeCkPreA

This is a pull-down selection for the A train pre-test
results of the probe check, as applicable.

Text

20





Page 11 of 54


-------
Table Name: tblRunHeader30B
Table Description: Method 30 B Header Run Data

Field Name

Field Description

Field Type

Size

Key

Required

StackTCCKPostB

This is a pull-down selection for the B train post-test
results of the thermocouple check, as applicable.

Text

25





StackTCCKPostA

This is a pull-down selection for the A train post-test
results of the thermocouple check, as applicable.

Text

25





StackTCCKPreB

This is a pull-down selection for the B train pre-test
results of the thermocouple check, as applicable.

Text

25





StackTCCKPreA

This is a pull-down selection for the A train pre-test
results of the thermocouple check, as applicable.

Text

20





LeakRtPostB

The B train post-test sampling train leak check rate.
The post-test leak rate must be less than or equal to
4 percent of the average sampling rate.

Double

8





TemperatureRunID

This is a drop down menu to select the method for
determining temperature and moisture. Available
selections include using calculated data from the
test, using data from another manual test method
or allowing manually entered data by the user.

Text

75





GasMeterUnits

This is the units that the dry gas meter displays. The
ERT limits selection to liters, cubic meters and cubic
feet.

Text

15





LeakRtPostA

The A train post-test sampling train leak check rate.
The post-test leak rate must be less than or equal to
4 percent of the average sampling rate.

Double

8





HighPointCalibration

This is the highest mass which the technician selects
for calibration of the analytical instrument.

Double

8





LeakRtPreB

The B train pre-test sampling train leak check rate.
The pre-test leak rate must be less than or equal to
4 percent of the initial sampling rate.

Double

8





SorbentTrapCkPreB

This is a pull-down selection for the B train pre-test
results of the sorbent trap check, as applicable.

Text

20





H20HDR

This is the calculated moisture percent based upon
the method selected in tsHDR unless the user
selected "User Entered".

Double

8





H20RunlD

This is the H20 run identification for the period
corresponding to the time for the emissions test
documented in this record. It is selected from a list
of available H20 runs by the user. The user also has
the option to select "User Entered".

Text

75





Page 12 of 54


-------
Table Name: tblRunHeader30B
Table Description: Method 30 B Header Run Data

Field Name

Field Description

Field Type

Size

Key

Required

MercuryMassUnits

This field provides the metric units associated with
all the reported mass values used in the sample
data tab. Metric mass values available range from
grams (g) to nanograms (ng).

Text

10





ProcRunID

This is the run id of the process parameter
associatied with the same time the test was
performed. The user uses a drop down menu to
select the process parameter which is stored in the
"Process ParamID" field of table
"tbIProcessRunData".

Text

75





CpHDRB

This is the train B (if used) Pitot tube coefficient
which is dimensionless. The Pitot tube coefficient
for an S-type Pitot can range from 0.80 to 0.88 but is
usually between 0.84 and 0.864. The Cp for a
standard Pitot is 0.99.

Double

8





ExpectedMassHg

This is the mass value of Hg expected to be collected
in Section 1 of the sample trap. The expected mass
is used to assess the acceptability of the spike level
used during the field recovery test.

Double

8





VIcComA

This is the sample train A sum of the volume or
weight of the moisture condensed in each of the
impingers or otherwise measured to the nearest
milliliter. In the ERT application this field is shown
as "Vic Components".

Double

8





LowPointCalibration

This is the lowest mass which the technician selects
for calibration of the analytical instrument.

Double

8





LabReportMDL

The laboratory must establish their minimum
detection limit (MDL). Method 30B requires that the
MDL must be determined at least once for the
analytical system using an MDL study.

Double

8





FcHDR

The value "Fc" is the ratio of the theoretical carbon
dioxide produced during combustion to the higher
heating value of the fuel combusted. With carbon
dioxide, the emission rate in Ib/MMBtu can be
calculated from wet or dry emissions concentration.

Long Integer

4





FwHDR

The value "Fw" is the ratio of the quantity of wet
effluent gas generated by combustion to the gross
calorific value of the fuel. With wet oxygen and
moisture concentration, the emission rate in
Ib/MMBtu can be calculated.

Long Integer

4





Page 13 of 54


-------
Table Name: tblRunHeader30B
Table Description: Method 30 B Header Run Data

Field Name

Field Description

Field Type

Size

Key

Required

FdHDR

The value "Fd" is the ratio of the quantity of dry
effluent gas generated by combustion to the gross
calorific value of the fuel. With oxygen
concentration, the emission rate in Ib/MMBtu can
be calculated from the dry pollutant emissions
concentration.

Long Integer

4





FuelType

This is a pull-down selection of the Fuel Type which
also populates the three F-factor fields FdHDR,
FwHDR and FcHDR with the values presented in
Table 19-2 of EPA Method 19. In addition, the user
may select "Override" and enter fuel specific F-
factors.

Text

25





VIcComB

This is the sample train A sum of the volume or
weight of the moisture condensed in each of the
impingers or otherwise measured to the nearest
milliliter. In the ERT application this field is shown
as "Vic Components".

Double

8





CpHDRA

This is the train A Pitot tube coefficient which is
dimensionless. The Pitot tube coefficient for an S-
type Pitot can range from 0.80 to 0.88 but is usually
between 0.84 and 0.864. The Cp for a standard
Pitot is 0.99.

Double

8





MeterBoxB

This is the identification number of Dry Gas Meter B.
The dry gas meter is the piece of hardware
responsible for quantifying the volume of gas
passing through the meter. The ID is necessary for
calibration documentation purposes.

Text

25





DH@HDRB

The Delta H @ (AH@) for sample train B. The AH@
is the orifice pressure differential in inches of H20
of an isokinetic sampling train meterbox (such as
used for Method 5 sampling) that correlates to 0.75
cfm at 5282R and 29.92 in Hg.

Double

8





YHDRB

This is the dry gas meter correction coefficient,
gamma, of sampling train A meterbox. In the
displayed header screen, gamma is shown as "Y".
The units of gamma are dimensionless.

Double

8





DH@HDRA

The Delta H @ (AH@) for sample train A. The AH@
is the orifice pressure differential in inches of H20
of an isokinetic sampling train meterbox (such as
used for Method 5 sampling) that correlates to 0.75
cfm at 5282R and 29.92 in Hg.

Double

8





YHDRA

This is the dry gas meter correction coefficient,
gamma, of sampling train A meterbox. In the
displayed header screen, gamma is shown as "Y".
The units of gamma are dimensionless.

Double

8





Page 14 of 54


-------
Table Name: tblRunHeader30B
Table Description: Method 30 B Header Run Data

Field Name

Field Description

Field Type

Size

Key

Required

ProbeA

This is the sample probe identification number. The
ID is necessary for calibration documentation
purposes.

Text

50





StackTCA

This is the ID of the A thermocouple used for
monitoring the stack gas temperature. The ID is
necessary for calibration documentation purposes.

Text

25





PbHDR

The barometric pressure of the sampling location.
The pressure is reported in units of inches of
mercury at the sampling platform. User obtained
weather service pressures are adjusted for the
differences in pressure due to differences in
elevation.

Double

8





ReagBoxA

This is the identification number of Control Console
A. The control console is the combination of the dry
gas meter, pumps, temperature controllers,
manometers, etc. The ID is necessary for calibration
documentation purposes.

Text

25





ProbeB

This is the sample probe identification number. The
ID is necessary for calibration documentation
purposes.

Text

50





MeterBoxA

This is the identification number of Dry Gas Meter
A. The dry gas meter is the piece of hardware
responsible for quantifying the volume of gas
passing through the meter. The ID is necessary for
calibration documentation purposes.

Text

25





TechnicianName

This field is the name of the person that operated
the equipment used to collect the sample.

Text

25





RunDate

PK- This is the date that the test was performaned.

Date/Time

8

Primary



RunNumber

PK- This is for the Run Number of the test. This
number is assigned by the test company. Generally,
the run number is an integer value which indicates
the sequence order for the performance of the test
method for the location.

Text

50

Primary



JobNumber

This is the contractors project or job number. Used
with the spreadsheet import.

Text

25





Method

PK- The field identifies the method used to measure
the analyte emissions. The test method was one of
the user selected isokinetic or manual sampling
methods which were entered in Item 2a of the Test
Plan.

Text

20

Primary



SorbentTrapCkPostB

This is a pull-down selection for the B train post-test
results of the sorbent trap check, as applicable.

Text

20





Page 15 of 54


-------
Table Name: tblRunHeader30B
Table Description: Method 30 B Header Run Data

Field Name

Field Description

Field Type

Size

Key

Required

ReagBoxB

This is the identification number of Control Console
B if used. The control console is the combination of
the dry gas meter, pumps, temperature controllers,
manometers, etc. The ID is necessary for calibration
documentation purposes.

Text

25





AnalysisMethod

This is information to identify the method used
extract, prepare and analyze the collected samples.

Text

50





VacCkPostB

The vacuum at which the B train post sampling train
leak checks was performed.

Double

8





VacCkPostA

The vacuum at which the A train post sampling train
leak checks was performed.

Double

8





StackTCB

This is the ID of the B thermocouple used for
monitoring the stack gas temperature. The ID is
necessary for calibration documentation purposes.

Text

25





VacCkPreA

The vacuum at which the A train pre sampling train
leak checks was performed.

Double

8





PgHDR

This is the static pressure (inches of water), of the
sampling location. Some screens show Pstatic or Pg.
Static pressure is typically measured with a Pitot
tube. The value is the difference between the stack
and local atmospheric pressure.

Double

8





AnalysisTechnician

This is the name of the person operating the trap
analysis equipment.

Text

50





TrapAnalysisSource

This is the combined equipment and apparatus used
to perform sample analyses. This includes any
associated sample preparation apparatus e.g.,
digestion equipment, spiking systems, reduction
devices, etc., as well as analytical instrumentation.

Text

50





TrapManufacturer

This is the manufacturer of the sample cartridge or
sleeve containing a sorbent media (typically
activated carbon treated with iodine or some other
halogen) with multiple sections separated by an
inert material such as glass wool.

Text

50





PercCOHDR

This is the carbon monoxide percentage which
defaults to zero (0). ... not used for method 5 or 202

Double

8





LeakRtPreA

The A train pre-test sampling train leak check rate.
The pre-test leak rate must be less than or equal to
4 percent of the initial sampling rate.

Double

8





VacCkPreB

The vacuum at which the B train pre sampling train
leak checks was performed.

Double

8





Page 16 of 54


-------
Table Name: tblRunHeader30B
Table Description: Method 30 B Header Run Data

Field Name

Field Description

Field Type

Size

Key

Required

PstdHDR

This is the standard pressure which defaults to EPA
standard of 29.92 inches of mercury. When the test
method performed requires the use of a different
standard pressure, the user can change the "29.92"
in this field to the pressure specified.

Double

8





Perc02HDR

The oxygen percent of the gas stream tested. The
pull-down to the right of the field for the 02
concentration provides access to the results of
instrumental measurements of 02.

Double

8





PercC02Runld

This is the run id of a Method 3A test for C02 if the
users selects the C02 run from the pull down menu.

Text

75





Location

PK-This is the unique sampling location name, such
as inlet, stack, ESP inlet, scrubber outlet, etc. which
was provided during the Test Plan preparation.

Text

50

Primary



Perc02Runld

This is the run id of a Method 3A test for 02 if the
users selects the 02 run from the pull down menu.

Text

75





tstdHDR

This is the standard temperature which defaults to
EPA standard of 68 degrees F. When the test
method performed requires the use of a different
standard temperature, the user can change the "68"
in this field to the temperature specified.

Double

8





PercC02HDR

The carbon dioxide percent of the gas stream
tested. The pull-down to the right of the field for the
C02 concentration provides access to the results of
instrumental measurements of C02.

Double

8





Table Name: tblRunPoints30B
Table Description: Method 30 B Point Run Data

Field Name

Field Description

Field Type

Size

Key

Required

DryGasB

RF- This is the inlet or outlet temperature of sample
gas at Dry Gas Meter B, degrees F.

Double

8



Req.

Method

RF- The field identifies the method used to measure
the analyte emissions. The test method was one of
the user selected isokinetic or manual sampling
methods which were entered in Item 2a of the Test
Plan.

Text

20



Req.

SampleRateB

RF- This is the train B sampling rate, measured in
the units of measure selected on the "Header Data"
tab.

Double

8



Req.

DryGasA

RF- This is the inlet or outlet temperature of sample
gas at Dry Gas Meter A, degrees F.

Double

8



Req.

Page 17 of 54


-------
Table Name: tblRunPoints30B
Table Description: Method 30 B Point Run Data

Field Name

Field Description

Field Type

Size

Key

Required

PumpVacA

This is train A sampling pump vacuum, measured in
inches mercury.

Double

8





PumpVacB

This is train B sampling pump vacuum, measured in
inches mercury.

Double

8





SampleRateA

RF- This is the train A sampling rate, measured in
the units of measure selected on the "Header Data"
tab.

Double

8



Req.

Notes

These are any observations or comments
concerning the test run.

Text

255





RunNumber

RF- This is for the Run Number of the test. This
number is assigned by the test company. Generally,
the run number is an integer value which indicates
the sequence order for the performance of the test
method for the location.

Text

20



Req.

Location

RF- This is the unique sampling location name, such
as inlet, stack, ESP inlet, scrubber outlet, etc. which
was provided during the Test Plan preparation.

Text

50



Req.

JobNumber

This is the contractor's project or job number. Used
with the spreadsheet import.

Text

25





EndTime

RF- This is the number of minutes of cumulative
sampling time at the end of sampling at the sample
point.

Double

8



Req.

TrapTempB

This is the temperature of the sampling trap B,
degrees F.

Double

8





RunDate

RF- This is the date that the test was performaned.

Date/Time

8



Req.

Clock

This is the actual local clock time at the start of
sampling at a point.

Date/Time

8





ProbeTempB

This is the temperature of the sampling probe B,
degrees F.

Double

8





ProbeTempA

This is the temperature of the sampling probe A,
degrees F.

Double

8





StackTempB

RF- This is the train B measured stack temperature
of the effluent gas at the sampling point and is
expressed as degrees F. The values in the stack
temp are used in subsequent calculations.

Double

8



Req.

StackTempA

RF- This is the train A measured stack temperature
of the effluent gas at the sampling point and is
expressed as degrees F. The values in the stack
temp are used in subsequent calculations.

Double

8



Req.

Page 18 of 54


-------
Table Name: tblRunPoints30B
Table Description: Method 30 B Point Run Data

Field Name

Field Description

Field Type

Size

Key

Required

OrificePresActual

Orifice pressure actually sampled or reached,
measured in inches of water. The values in the
"Orifice Pressure Actual" are used in subsequent
calculations.

Double

8





OrificePresDesired

This is the orifice pressure setting required for
sampling isokinetically, measured by inches water.

Double

8





Velocity

This is the velocity pressure (Ap) expressed in inches
of water. Values in "AP" are used in the calculation
of isokinetics, average delta p, velocity of gas
stream and actual and standard stack gas flow.

Double

8





GasMeterB

RF- The dry gas meter B volume reading at the
beginning (or end) of the sampling at a point. This
means that the final (or initial) volume reading is
recorded in a row without a point label and no
other recorded point data.

Double

8



Req.

Point

RF- This is the sampling point label used by the test
company, such as Al, A-l, D-2, etc.

Text

8



Req.

BeginTime

This is the number of minutes of cumulative
sampling time prior to the beginning of sampling at
the sample point.

Double

8





GasMeterA

RF- The dry gas meter A volume reading at the
beginning (or end) of the sampling at a point. This
means that the final (or initial) volume reading is
recorded in a row without a point label and no
other recorded point data.

Double

8



Req.

TrapTempA

This is the temperature of sampling trap A, degrees
F.

Double

8





Table Name: tblRunLab30B
Table Description: Method 30 B Lab Data

Field Name

Field Description

Field Type

Size

Key

Required

AM If

This is used to enter an aggregate Hg Mass. Totals
to AMI.

Double

8





AMle

This is used to enter an aggregate Hg Mass. Totals
to AMI.

Double

8





AMlc

This is used to enter an aggregate Hg Mass. Totals
to AMI.

Double

8





BMlh

This is used to enter an aggregate Hg Mass. Totals
to BM1.

Double

8





Page 19 of 54


-------
Table Name: tblRunLab30B
Table Description: Method 30 B Lab Data

Field Name

Field Description

Field Type

Size

Key

Required

AMlg

This is used to enter an aggregate Hg Mass. Totals
to AMI.

Double

8





BSpikePen

This is for backward compatibility... this field is not
used.

Yes/No

1





BMlf

This is used to enter an aggregate Hg Mass. Totals
to BM1.

Double

8





AMla

This is used to enter an aggregate Hg Mass. Totals
to AMI.

Double

8





AMlh

This is used to enter an aggregate Hg Mass. Totals
to AMI.

Double

8





BMla

This is used to enter an aggregate Hg Mass. Totals
to BM1.

Double

8





BMlb

This is used to enter an aggregate Hg Mass. Totals
to BM1.

Double

8





BMlc

This is used to enter an aggregate Hg Mass. Totals
to BM1.

Double

8





BMle

This is used to enter an aggregate Hg Mass. Totals
to BM1.

Double

8





BMlg

This is used to enter an aggregate Hg Mass. Totals
to BM1.

Double

8





AMlb

This is used to enter an aggregate Hg Mass. Totals
to AMI.

Double

8





BBreakthroughPen

This is for backward compatilbility... this field is not
used.

Yes/No

1





BMld

This is used to enter an aggregate Hg Mass. Totals
to BM1.

Double

8





Location

PK-This is the unique sampling location name, such
as inlet, stack, ESP inlet, scrubber outlet, etc. which
was provided during the Test Plan preparation.

Text

50

Primary



BM3

This is the mass determined by the analysis of the
third section of sorbent trap B. The units of measure
displayed after the entry fields are the units
selected on the "Header Data" screen. Currently the
ERT does not accommodate a three part trap.

Double

8





PlantID

FK- This field is not used.

Text

50

Foreign



Page 20 of 54


-------
Table Name: tblRunLab30B
Table Description: Method 30 B Lab Data

Field Name

Field Description

Field Type

Size

Key

Required

Method

PK- The field identifies the method used to measure
the analyte emissions. The test method was one of
the user selected isokinetic or manual sampling
methods which were entered in Item 2a of the Test
Plan.

Text

50

Primary



RunNumber

PK- This is for the Run Number of the test. This
number is assigned by the test company. Generally,
the run number is an integer value which indicates
the sequence order for the performance of the test
method for the location.

Text

50

Primary



RunDate

PK- This is the date that the test was performaned.

Date/Time

8

Primary



ATrapID

This is the alphanumeric code for trap A as required
by section 6.1.1 of Method 30B which uniquely
identifies a cartridge or sleeve containing a sorbent
media with two sections separated by an inert
material.

Text

50





AMI

This is the mass determined by the analysis of the
first section of sorbent trap A and the inert
separation material. The units of measure displayed
after the date entry fields are the units selected on
the paired train "Header Data" screen.

Double

8





AM2

This is the mass determined by the analysis of the
second section of sorbent trap A. The units of
measure displayed after the entry fields are the
units selected on the "Header Data" screen.

Double

8





BMS

This is the mass which was spiked (added) to
"Section 1" of one of the pairs of traps used for the
Field Recovery Test. If the B train of this run was
spiked, it would have a value entered.

Double

8





AM3

This is the mass determined by the analysis of the
third section of sorbent trap A. The units of measure
displayed after the entry fields are the units
selected on the "Header Data" screen. Currently the
ERT does not accommodate a three part trap.

Double

8





ABreakthroughPen

This is for backward compatilbility... this field is not
used.

Yes/No

1





ASpikePen

This is for backward compatilbility... this field is not
used.

Yes/No

1





BTrapID

This is the alphanumeric code for trap B as required
by section 6.1.1 of Method 30B which uniquely
identifies a cartridge or sleeve containing a sorbent
media with two sections separated by an inert
material.

Text

50





Page 21 of 54


-------
Table Name: tblRunLab30B
Table Description: Method 30 B Lab Data

Field Name

Field Description

Field Type

Size

Key

Required

BM1

This is the mass determined by the analysis of the
first section of sorbent trap B and the inert
separation material. The units of measure displayed
after the date entry fields are the units selected on
the paired train "Header Data" screen.

Double

8





BM2

This is the mass determined by the analysis of the
second section of sorbent trap B. The units of
measure displayed after the entry fields are the
units selected on the "Header Data" screen.

Double

8





AMS

This is the mass which was spiked (added) to
"Section 1" of one of the pairs of traps used for the
Field Recovery Test. If the A train of this run was
spiked, it would have a value entered.

Double

8





AMld

This is used to enter an aggregate Hg Mass. Totals
to AMI.

Double

8





Table Name: tbIRunDatalTM
Table Description: Instrumental Methods Run Data

Field Name

Field Description

Field Type

Size

Key

Required

FuelType

This is a pull-down selection of the Fuel Type which
also populates the three F-factor fields FdHDR,
FwHDR and FcHDR with the values presented in
Table 19-2 of EPA Method 19. In addition, the user
may select "Override" and enter fuel specific F-
factors.

Text

50





CgasUnits

This is the measurment units (typically the same as
the measured units but corrected to dry conditions).

Text

50





Cgas

This is the calculated emissions concentration
corrected for bias and drift and in the proper
measurement units.

Double

8





Cavg Units

This is the measurement units (ppmvd, ppmvw,
ppbvd, %vd, %vw etc.) for Cavg.

Text

50





Cavg

This is the Average concentration from the
instrumant during the test run.

Double

8





CalPostH Drift

This is a value calculated by the ERT and is the post
run calibration high level system drift.

Double

8





CalPostHSysBias

This is a value calculated by the ERT and is the post
run calibration high level system bias.

Double

8





Page 22 of 54


-------
Table Name: tbIRunDatalTM
Table Description: Instrumental Methods Run Data

Field Name

Field Description

Field Type

Size

Key

Required

CalPostHRV

This is the post run calibration high level results
value and is the instrument response when
challenged with the high level gas.

Double

8





CalPostHCyllD

Cylinder identification number on the gas cylinder
for the post run high level calibration gas. This is
populated by selecting the previously entered
information from a drop down menu of the
calibration cylinder informaion entered in the Test
Plan.

Text

50





CalPostZSysBias

This is a value calculated by the ERT and is the post
run calibration zero bias.

Double

8





CalPostZRV

This is the post run calibration Zero Results Value
and is the instrument response when challenged
with the zero gas.

Double

8





Fd

The value "Fd" is the ratio of the quantity of dry
effluent gas generated by combustion to the gross
calorific value of the fuel. With oxygen
concentration, the emission rate in Ib/MMBtu can
be calculated from the dry pollutant emissions
concentration.

Long Integer

4





CEMSLbMMBTU

This is the facilities as indicated CEMS value
recorded in pounds per million British Thermal Units
(BTU) and for the same time period as performed by
the instrumental test method. Added 3/12

Double

8





CalPostZDrift

This is a value calculated by the ERT and is the post
run calibration zero drift.

Double

8





CEMSLbHR

This is the facilities indicated CEMS value recorded
in pounds per hour units and for the same time
period as performed by the instrumental test
method. Added 3/12

Double

8





CEMS02Corr

This is the facilities recorded 02 correction perc

Double

8





Exclude

This is a check box for the user to indicate that the
test run is to be excluded from the Performance
Specification Test (PST) Relative Accuracy Test
Assessment (RATA) calculation.

Yes/No

1





ProcRunID

This is a drop down menu selection of the Process
run ID documenting the process rate during the
same time measurements for the reference test
method. Process based emissions are the test
method emission rate divided by the associated
process rate.

Text

50





Page 23 of 54


-------
Table Name: tbIRunDatalTM
Table Description: Instrumental Methods Run Data

Field Name

Field Description

Field Type

Size

Key

Required

MMBTUHrCERMS

This is the facilities indicated CEMS fuel combustion
rate in British Thermal Units (BTU) per hour and for
the same time period as performed by the
instrumental test method. Added 5/11

Double

8





FlowCERMS

This is the facilities as measured CEMS stack gas
flow value recorded in the same units and for the
same time period as performed by the instrumental
test method. Added 5/11

Double

8





CEMSPPM

This is the facilities as measured CEMS value
recorded in parts per million (PPM) units and for the
same time period as performed by the instrumental
test method. Added 3/12

Double

8





CalPreHCyllD

Cylinder identification number on the gas cylinder
for the pre run high level calibration gas. This is
populated by selecting the previously entered
information from a drop down menu of the
calibration cylinder informaion entered in the Test
Plan.

Text

50





Fw

The value "Fw" is the ratio of the quantity of wet
effluent gas generated by combustion to the gross
calorific value of the fuel. With wet oxygen and
moisture concentration, the emission rate in
Ib/MMBtu can be calculated.

Long Integer

4





CalPostZCyllD

Cylinder identification number on the gas cylinder
for the post run zero calibration gas. This is
populated by selecting the previously entered
information from a drop down menu showing
calibration cylinder informaion entered in the Test
Plan.

Text

50





RunStatus

added 3/6/07 - Accepted/Rejected

Text

20





CgaswUnits

This is the measurment units (typically the same as
the measured units but wet concentration basis).

Text

50





Cgasw

This is the calculated emissions concentration
corrected for bias and drift but on a wet basis.

Double

8





Fo

This is the Fo and is the ratio of excess Oxygen and
Carbon Dioxide. Calculation uses (20.9 -
%02)/%C02. calc'd (20.9 - %02)/%C02

Double

8





Fc

The value "Fc" is the ratio of the theoretical carbon
dioxide produced during combustion to the higher
heating value of the fuel combusted. With carbon
dioxide, the emission rate in Ib/MMBtu can be
calculated from wet or dry emissions concentration.

Long Integer

4





CEMSValue

This is the facilities indicated CEMS value

Double

8





Page 24 of 54


-------
Table Name: tbIRunDatalTM
Table Description: Instrumental Methods Run Data

Field Name

Field Description

Field Type

Size

Key

Required

FlowRateRunID

This is a drop down menu to select the method for
determining the stack flow rate. Available selections
include using data from a manual test method or
allowing manually entered data by the user.

Text

50





Location

PK-This is the unique sampling location name, such
as inlet, stack, ESP inlet, scrubber outlet, etc. which
was provided during the Test Plan preparation.

Text

50

Primary



Method

PK- The field identifies the method used to measure
the analyte emissions. The test method was one of
the user selected isokinetic or manual sampling
methods which were entered in Item 2a of the Test
Plan.

Text

50

Primary



Run

PK- This is for the Run Number of the test. This
number is assigned by the test company. Generally,
the run number is an integer value which indicates
the sequence order for the performance of the test
method for the location.

Text

50

Primary



RunDate

This is the date that the test was performaned.

Date/Time

8





StartTime

Hour-minute-second AM/PM that run was
performed. Time can be entered as 24 hour time or
12 hour time with the AM/PM extension and the
time will revert to the latter time format.

Date/Time

8





CalPreHSysBias

This is a value calculated by the ERT and is the pre
run calibration high level bias.

Double

8





Qsd

This is the calculated stack flow in dscfm based upon
the method selected in FlowRateRunID. If the user
selected "User Entered" the value is the number
entered.

Double

8





CalPreHDrift

Drift in Percent

Double

8





MoisturePerc

The moisture percent of the gas stream tested. The
pull-down to the right of the field for the moisture
provides access to the results of instrumental
measurements of moisture.

Double

8





MoistureRunID

This is the run ID of method used for moisture (if
pulled from that method)

Text

50





PercC02

The carbon dioxide percent of the gas stream
tested. The pull-down to the right of the field for the
C02 concentration provides access to the results of
instrumental measurements of C02.

Double

8





C02RunlD

This is the run ID of method used for C02 (if pulled
from that method)

Text

50





Page 25 of 54


-------
Table Name: tbIRunDatalTM
Table Description: Instrumental Methods Run Data

Field Name

Field Description

Field Type

Size

Key

Required

Perc02

The oxygen percent of the gas stream tested. The
pull-down to the right of the field for the 02
concentration provides access to the results of
instrumental measurements of 02.

Double

8





CalPreZCyllD

Cylinder identification number on the gas cylinder
for the pre run zero calibration gas. This is
populated by selecting the previously entered
information from a drop down menu showing
calibration cylinder informaion entered in the Test
Plan.

Text

50





EndTime

Hour-minute-second AM/PM that run was
completed. Time can be entered as 24 hour time or
12 hour time with the AM/MP extension and the
time will revert to the latter time format.

Date/Time

8





02RunlD

This is the run ID of method used for 02 (if pulled
from that method)

Text

50





CalPreZDrift

Drift in Percent

Double

8





CalPreZRV

This is the pre run calibration Zero Results Value and
is the instrument response when challenged with
the zero gas.

Double

8





CalPreHRV

This is the pre run calibration high results value and
is the instrument response when challenged with
the high level gas.

Double

8





CalSet

The number assigned to the set of readings. The
number used to associate this data to the data
entered in "Calibrations" tab

Long Integer

4





Timelnterval

This is the time interval between readings.

Text

50





Readings

This is the number of readings or average number of
readings for the Time Interval specified in
Timelnterval.

Long Integer

4





OperUnits

This is the units used for the operating range.

Text

25





OperRange

This is the acceptable operating range or fluctuation
of concentrations for the analytes being measured.

Double

8





AnalyzerSN

This is the serial numbet of the Instrument Analyzer.

Text

50





AnalyzerModel

This is the Instrument Analyzer Model.

Text

50





AnalyzerMake

This is the Instrument Analyzer Make.

Text

50





CalPreZSysBias

This is a value calculated by the ERT and is the pre
run calibration zero level system bias.

Double

8





Page 26 of 54


-------
Table Name: tbIRunDatalTM
Table Description: Instrumental Methods Run Data

Field Name

Field Description

Field Type

Size

Key

Required



Table Name: tbICals
Table Description: Instrument Methods Calibration Data

Field Name

Field Description

Field Type

Size

Key

Required

DZError

This is a value calculated by the ERT and is the Direct
zero level calibration Error

Text

50





DHCyllD

Cylinder identification number on the gas cylinder
for the high calibration gas. This is populated by
selecting the previously entered information from a
drop down menu showing all the calibration
cylinder informaion originaly entered in the Test
Plan.

Text

50





DMCyllD

Cylinder identification number on the gas cylinder
for the mid calibration gas. This is populated by
selecting the previously entered information from a
drop down menu showing all the calibration
cylinder informaion originaly entered in the Test
Plan.

Text

50





DIError

This is a value calculated by the ERT and is the Direct
low level calibration Error

Text

50





DLRV

This is the Direct Low Level Results Value and is the
instrument response when challenged with the low
level calibration gas.

Double

8





DLCyllD

Cylinder identification number on the gas cylinder
for the low calibration gas. This is populated by
selecting the previously entered information from a
drop down menu showing all the calibration
cylinder informaion originaly entered in the Test
Plan.

Text

50





DZRV

This is the Direct Zero Results Value and is the
instrument response when challenged with the zero
gas.

Double

8





DZCyllD

Cylinder identification number on the gas cylinder
for the zero calibration gas. This is populated by
selecting the previously entered information from a
drop down menu showing all the calibration
cylinder informaion originaly entered in the Test
Plan.

Text

50





Span

Calibration Span for this set

Double

8





Set

PK- The number assigned by the user to the set of
readings. The number is used to associate this data
to the run calibration data.

Long Integer

4

Primary



Page 27 of 54


-------
Table Name: tbICals
Table Description: Instrument Methods Calibration Data

Field Name

Field Description

Field Type

Size

Key

Required

Method

PK- The field identifies the method used to measure
the analyte emissions. The test method was one of
the user selected isokinetic or manual sampling
methods which were entered in Item 2a of the Test
Plan.

Text

50

Primary



DMError

This is a value calculated by the ERT and is the Direct
mid level calibration Error

Text

50





Location

PK-This is the unique sampling location name, such
as inlet, stack, ESP inlet, scrubber outlet, etc. which
was provided during the Test Plan preparation.

Text

50

Primary



DHRV

This is the Direct High Level Results Value and is the
instrument response when challenged with the high
level calibration gas.

Double

8





DHError

This is a value calculated by the ERT and is the Direct
high level calibration Error

Text

50





SZCyllD

Cylinder identification number on the gas cylinder
for the zero calibration gas. This is populated by
selecting the previously entered information from a
drop down menu showing all the calibration
cylinder informaion originaly entered in the Test
Plan.

Text

50





SZRV

This is the System Zero Results Value and is the
instrument response when challenged with the zero
gas.

Double

8





SZError

This is a value calculated by the ERT and is the
system zero level calibration Error

Text

50





SHCyllD

Cylinder identification number on the gas cylinder
for the high calibration gas. This is populated by
selecting the previously entered information from a
drop down menu showing all the calibration
cylinder informaion originaly entered in the Test
Plan.

Text

50





SHRV

This is the System High Level Results Value and is
the instrument response when challenged with the
high level calibration gas.

Double

8





SHError

This is a value calculated by the ERT and is the
system high level calibration Error

Text

50





DMRV

This is the Direct Mid Level Results Value and is the
instrument response when challenged with the mid
level calibration gas.

Double

8





Page 28 of 54


-------
Table Name: tbIPSTCals
Table Description: Performance Standard Test Calibration Drift Data

Field Name

Field Description

Field Type

Size

Key

Required

Location

PK- This identifies the test location for the
calibration drift data.

Text

50

Primary



High

This is the high value for the calibration for the day.

Double

8





Low

This is the low value for the calibration for the day.

Double

8





Method

PK- This identifies the test method for the
calibration drift data.

Text

50

Primary



Day

PK- This identifies the day sequence for the
calibration drift data.

Long Integer

4

Primary



Table Name: tbIPSTHeader
Table Description: Performance Standard Test Header Data

Field Name

Field Description

Field Type

Size

Key

Required

PPMvStandard

If specified in the applicable regulation, this is the
emission limit in units of actual parts per million
(PPM) by volume.

Double

8





Lb/Hr

This is the ERT calculated emissions in pounds per
hour for the concurent time period of the CEMS run.

Double

8





Lb/MMBTU

This is the ERT calculated emissions in pounds per
million BTU for the concurent time period of the
CEMS run.

Double

8





Lb/MMBTUStandard

If specified in the applicable regulation, this is the
emission limit in units of pounds per million BTU.

Double

8





Lb/HrStandard

If specified in the applicable regulation, this is the
emission limit in units of pounds per hour.

Double

8





PPM@02Corr

If specified in the applicable regulation, this is the
emission limit in units of parts per million (PPM) by
volume corrected to the 02 concentration required
by the emission standard.

Double

8





02Corr

If specified in the applicable regulation, this is the
oxygen concentration for correcting the actual
measured concentration.

Double

8





RAStartDate

This is the start date for the calibration drift test.

Date/Time

8





CDEndDate

This is the end date for the calibration drift test.

Date/Time

8





HighCal

This is the high calibration value for the CEMS
instrument.

Double

8





LoCal

This is the low calibration value for the CEMS
instrument.

Double

8





Page 29 of 54


-------
Table Name: tbIPSTHeader
Table Description: Performance Standard Test Header Data

Field Name

Field Description

Field Type

Size

Key

Required

Span

This is the span for the CEMS instrument.

Double

8





Method

PK- This the reference test method used to assess
the relative accuracy of the CEMS.

Text

50

Primary



mmBTUTollse

This can be "C02" or "02" and determines which
one is used for the calculations.

Text

3





Location

PK- This is the test location for the reference test
method used to assess the relative accuracy of the
CEMS.

Text

50

Primary



RAEndDate

This is the end date for the relative accuracy test
audit evaluation.

Date/Time

8





Table Name: tbITestPlan
Table Description: Test Plan Data

Field Name

Field Description

Field Type

Size

Key

Required

TestRepEmail

This is the email of the test company representative
that reviewed the test plan. Added 1/30/12

Text

255





TestSchedule

This field is a text field for the test company or the
source to advise the regulatory agency of the
proposed schedulet for the performance test.

Memo

0





Comments

This field is a text field for the test company or the
source to provide additional inforamtion on details
of the test program.

Memo

0





FacRepName

The person authorized to represent the facility
being tested that reviewed the test plan or report.

Text

50





FacRepEmail

This is the email of the Facility representative that
reviewed the test plan. Added 1/30/12

Text

255





FacRepTitle

The corporate title of the person authorized to
represent the facility being tested.

Text

50





FacRepCompany

The public or commercial name of the company
owning the facility (i.e., the full name that
commonly appears on invoices, signs, or other
business documents).

Text

50





CalibGasConcSummar

y

This is used for backward compatibility with old
project data sets and is not used now.

Memo

0





TestRepName

The person in the test company that reviewed the
source test plan or report.

Text

50





Page 30 of 54


-------
Table Name: tbITestPlan
Table Description: Test Plan Data

Field Name

Field Description

Field Type

Size

Key

Required

EPASampleAuditDesc

This is used for backward compatibility with old
project data sets and is not used now.

Memo

0





TestRepTitle

The corporate title of the person in the test
company that reviewed the source test plan or
report.

Text

50





TestRepCompany

The public or commercial name of the test company
that commonly appears on invoices, signs or other
business documents.

Text

50





FacRepSignDate

The date that the authorized person reviewed the
test plan or report.

Date/Time

8





DilutionProposedYN

This is a set of check boxes indicating if a Method
205 dilution system for calibration gases will be
used. l=Yes, 2=No, 3=NA

Text

1





CalibGasCertProcedur
e

The text box contains an explanation for any
negative response or supplementary detail for
certification per EPA Traceability Protocol
procedures.

Memo

0





CalibGasCertifiedYN

This checkbox indicates whether or not all
calibration gases have a valid certification per EPA
Traceability Protocol procedures. l=Yes, 2=No, 3=NA

Text

1





EqupCalibrationYN

This checkbox indicates whether or not all testing
equipment been calibrated within the past 12
months.

Yes/No

1





EPASampleAuditYN

This checkbox indicates whether or not audit
samples are required.

Yes/No

1





OxygenConcDet3or3a

This is a drop down menu to select the method used
to determine the gas molecular weight, oxygen
concentration or carbon dioxide concentration.
Selection options include Method 3 or Method 3A

Text

40





OxygenConcDetYN

This is used for backward compatibility with old
project data sets and is not used now.

Yes/No

1





CyclonicFlowDesc

This field is for summary information on the
documentation of the presence or absence of
cyclonic flow and what the test company did to
correct the issues that precludes collecting a
represenative sampld.

Memo

0





CyclonicFlowYN

This field is for the user to indicate the availability of
documentation on the presence or absence of
cyclonic flow.

Yes/No

1





Page 31 of 54


-------
Table Name: tbITestPlan
Table Description: Test Plan Data

Field Name

Field Description

Field Type

Size

Key

Required

MeetMinReq

This field is for the user to explain why the methods
used at the sampling location provide a
representative sample and document any approval,
as applicable.

Memo

0





MeetMinReqYN

This checkbox indicates whether the test location
meets Method 1 criteria.

Yes/No

1





TestRepSignDate

The date that the authorized person for the test
company reviewed the test plan or report.

Date/Time

8





HrsPerYear

Normal hours the facility operates in a year. Added
6/8/2011

Long Integer

4





EquipCalibrationDesc

The text box contains an explanation for any
negative response for equipment not being
calibrated within 12 months..

Memo

0





TRTestRepTitle

This is the title of the Test Companies
Representative that performed the Final Test Report
Verification. Added 9/20/05

Text

50





PDSiDDate

This is the date which the PDS ID was originally
assigned to this file. Added 4/14

Date/Time

8





PDSiD

This is an alphanumeric value assigned by the ERT to
provide a unique indicator for this electronic report
to differentiate this report from all other submitted
reports. Added 4/14

Text

40





OpenExpandedQAQ

This is a check box field which is used to open the
visible Completeness and Quality Assessment
Review pages to full screen or the colapse it to a
smaller size. Added 3/20/13

Yes/No

1





OpenExpandedPD

This is a check box field which is used to open the
visible process data entry page to full screen or the
colapse it to a smaller size. Added 3/13/13

Yes/No

1





OpenExpandedTR

This is a check box field which is used to open the
visible regulatory agency test report review page to
full screen or the colapse it to a smaller size. Added
3/1/13

Yes/No

1





OpenExpandedSA

This is a check box field which is used to open the
visible test plan review page to full screen or the
colapse it to a smaller size. Added 2/21/13

Yes/No

1





OpenExpandedRun

This is a check box field which is used to open the
visible run data page to full screen or the colapse it
to a smaller size. Added 2/21/13

Yes/No

1





OpenExpanded

This is a check box field which is used to open the
test plan visible page to full screen or the colapse it
to a smaller size. Added 2/19/13

Yes/No

1





Page 32 of 54


-------
Table Name: tbITestPlan
Table Description: Test Plan Data

Field Name

Field Description

Field Type

Size

Key

Required

TestCoProjNum

The assigned project number for the testing project
by the test. Added 10/19/11 - nj request

Text

25





StateFacID

The state identification number as provided by a
state air pollution control agency. Added 10/19/11 -
nj request

Text

25





RATA

This is a checkbox indicating that the purpose of the
test was to satisfy a regulatory requirement to
perform a Relative Accuracy Test Audit comparing
installed Continuous Emissions Monitiring results
with results of a reference test method.

Yes/No

1





TRTestRepSignDate

This is the date that the Test Companies
Representative performed the Final Test Report
Verification. Added 9/20/05

Date/Time

8





TestlnAccordanceDes
c

This field is for summary details about the test
method used which are not readily available.
Information included include modifications and/or
alternative methods used. Attachments with greater
detail are suggested to supplement the summary
informaion.

Memo

0





PPE

This field is a text field for the test company or the
source to provide inforamtion on details of the
personal protective equipment that would be
needed for the test program.

Memo

0





TRTestRepCompany

This is the name of the Company that employs the
Test Companies Representitive that performed the
Final Test Report Verification. Added 9/20/05

Text

50





TRTestRepEMail

This is the email address of the Test Companies
Representitive that performed the Final Test Report
Verification. Added 1/30/12

Text

50





TRTestRepName

This is the name of the Test Companies
Representative that performed the Final Test Report
Verification. Added 9/20/05

Text

50





TRFacRepSignDate

This is the date that the Permitted Facilities
Representative performed the Final Test Report
review and verified that the report was true,
accurate and complete. Added 9/20/05

Date/Time

8





TRFacRepTitle

This is the title of the Permitted Facilities
Representative that performed the Final Test Report
Verification. Added 9/20/05

Text

50





TRFacRepCompany

This is the name of the Company that employs the
Permitted Facilities Representitive that performed
the Final Test Report Verification. Added 9/20/05

Text

50





Page 33 of 54


-------
Table Name: tbITestPlan
Table Description: Test Plan Data

Field Name

Field Description

Field Type

Size

Key

Required

TRFacRepEmail

This is the email address of the Permitted Facilities
Representative that performed the Final Test Report
Verification. Added 1/30/12

Text

50





TRFacRepName

This is the name of the Permitted Facilities
Representative that performed the Final Test Report
review and verified that the report was true,
accurate and complete. Added 9/20/05

Text

50





AFSid

EPA AIRS Facility System (AFS) number, added
9/8/05

Text

25





TesterComments

This is used for backward compatibility with old
project data sets and is not used now.

Memo

0





AgencyComments

This is used for backward compatibility with old
project data sets and is not used now.

Memo

0





see

RF-The eight digit Source Classification Code (SCC)
is selected through the use of the "Select SCC from
list" button. Added 1/19/06

Text

11



Req.

FacZip

RF- The mailing zip code in which the facility resides.

Text

50



Req.

TestCoCity

RF- The state in which the source test company
resides.

Text

50



Req.

TestCoAddress2

This is the continuation line for the physical address
of the test company.

Text

50





TestCoAddressl

RF- The standard address used to send mail to an
individual with the source test company.

Text

50



Req.

TestCoAddressFull

This is used for backward compatibility with old
project data sets and is not used now.

Memo

0





TestCoName

RF- The public or commercial name that commonly
appears on invoices, signs or other business
documents.

Text

50



Req.

TestlnAccordanceYN

This is used for backward compatibility with old
project data sets and is not used now.

Yes/No

1





FacLatitude

RF- Latitude of emission release point (typically the
stack), with a minimum of 5 decimal places.

Text

50



Req.

ApplRegs

This is used for backward compatibility with old
project data sets and is not used now.

Memo

0





FaclndustryType

North American Industry Classification System
numerical identifier. The digits designate the
economic sector, the subsector, the industry group,
the NAICS industry, and the national industry.

Text

100





Page 34 of 54


-------
Table Name: tbITestPlan
Table Description: Test Plan Data

Field Name

Field Description

Field Type

Size

Key

Required

FacEmail

RF- A working email address of the contact which
can be used to assist the reviewers.

Text

50



Req.

FacFax

The facsimile number of the facility through which
the contact can assist the reviewers.

Text

50





TestCoState

RF- The two letter state and mailing zip code of the
source test company.

Text

50



Req.

FacPOC

RF- The person with knowledge of the facility's
operations during the test program who can assist
reviewers of the test plan or test report if they have
questions.

Text

50



Req.

FacLongitude

RF- Longitude of emission release point (typically
the stack), with a minimum of 5 decimal places.

Text

50



Req.

FacState

RF- The two letter state and mailing zip code in
which the facility resides. Use the drop down menu
to select the two letter postal code for the State.

Text

50



Req.

FacCounty

RF- The county or parish in which the facility is
located. Use the drop down menu to select the
county. These will be available after the postal code
for the State is selected. Added 1/30/12

Text

50



Req.

FacCity

RF- The city in which the facility resides.

Text

50



Req.

FacAddress2

This is the continuation line for the physical address
of the facility.

Text

50





FacAddressl

RF- The address that describes the physical
(geographical) location of the front door or main
entrance of a facility site, including urban-style
street address or rural address.

Text

50



Req.

FacAddressFull

This is used for backward compatibility with old
project data sets and is not used now.

Memo

0





FacName

RF- The public or commercial name of the facility
site (i.e., the full name that commonly appears on
invoices, signs, or other business documents).

Text

50



Req.

TestPlanTitle

RF- This is the title chosen by the test company or
tested facility for the test program.

Text

100



Req.

TestPlanDate

RF- The date which the test report was initially
created. This date may be associated with the test
plan preparation.

Date/Time

8



Req.

TestPlanNumber

This field is for backwards compatibility and is not
used now.

Text

50





TestPlanID

PK- This is a unique ID for the Testplan record.

AutoNumber

4

Primary



Page 35 of 54


-------
Table Name: tbITestPlan
Table Description: Test Plan Data

Field Name

Field Description

Field Type

Size

Key

Required

FacPhone

RF- The phone number of the contact or the facility.

Text

50



Req.

Sectionll4

This is a checkbox indicating that the purpose of the
test was to satisfy a requirement under Section 114
of the Clean Air Act to perform the emission test.

Yes/No

1





SampLocDesc

This is used for backward compatibility with old
project data sets and is not used now.

Memo

0





SourceDesc

In this text box the user provides a summary
description of the source, a description of the
control equipment.

Memo

0





HowDataDocumented

This is used for backward compatibility with old
project data sets and is not used now.

Memo

0





OtherRegPurposeDes
c

List the secondary reasons for performing this
emissions test.

Memo

0





FINS

RF- EPA Facility Registry System number (FRS) is a
twelve digit number. The FRS number is a centrally
managed database that identifies facilities, sites or
places subject to environmental regulations or of
environmental interest.

Text

50



Req.

TestCoZip

RF- The mailing zip code of the source test company.

Text

50



Req.

StateRule

This is a checkbox indicating that the purpose of the
test was to satisfy a regulatory emission limit
requirement in a State Rule.

Yes/No

1





TestPurpose

This text box is to provide additional information on
the purpose for the test. The text box may also
contain information on those pollutants that are of
primary interest, DQO's, DQI's, and criteria to
determine if the test program met the DQO's.

Memo

0





SIP

This is a checkbox indicating that the purpose of the
test was to satisfy a regulatory emission limit
requirement in a State Implementation Plan.

Yes/No

1





NSRPSD

This is a checkbox indicating that the purpose of the
test was to satisfy a regulatory emission limit
requirement in a New Source Review or Prevention
of Significand Deterioration Permit.

Yes/No

1





Part65

This is a checkbox indicating that the purpose of the
test was to satisfy a regulatory emission limit
requirement in 40CFR Part 65.

Yes/No

1





Part63

This is a checkbox indicating that the purpose of the
test was to satisfy a regulatory emission limit
requirement in 40CFR Part 63.

Yes/No

1





Page 36 of 54


-------
Table Name: tbITestPlan
Table Description: Test Plan Data

Field Name

Field Description

Field Type

Size

Key

Required

Test Co Fax

RF- The facsimile number of the source test
company through which the contact can assist the
reviewers.

Text

50



Req.

TestCoPOC

RF-The person with knowledge of the design and
conduct of the source test program.

Text

50



Req.

Other

This is a checkbox indicating that there was some
other purpose for the test than one of the other
check boxes.

Yes/No

1





TestCoPhone

RF- The phone number of the source test company
through which the contact can assist the reviewers.

Text

50



Req.

Part61

This is a checkbox indicating that the purpose of the
test was to satisfy a regulatory emission limit
requirement in 40CFR Part 61.

Yes/No

1





TestCoEmail

RF- A working email address through which the
contact can assist the reviewers.

Text

50



Req.

AirPermitNumber

State or Federal Permit Number.

Text

50





Part60

This is a checkbox indicating that the purpose of the
test was to satisfy a regulatory emission limit
requirement in 40CFR Part 60.

Yes/No

1





PermittedSourcelD

This is the official State ID number of the emission
source as listed in the Title 5 permit. Many state and
local agencies have alphanumeric identifiers for
individual process operating units with an
associated name describing the unit.

Text

50





PermittedMaxProcess
Rate

Permitted Maximum Process Rate as listed in Title V
or state permit.

Text

50





MaxNormalOpRate

Maximum Normal Operation Process Rate as listed
in Title V or state permit.

Text

50





TargetProcessTestRat
e

Value of the target process rate for the test
program.

Text

50





PermittedSourceNam
e

This is the official name of the emission source as
listed in the Title 5 permit. Many state and local
agencies have alphanumeric identifiers for
individual process operating units with an
associated name describing the unit.

Text

50





Page 37 of 54


-------
Table Name: tbIEmisConcs
Table Description: Emission Concentrations selected for this test

Field Name

Field Description

Field Type

Size

Key

Required

Method

PK- This is the test method at this test location that
the emission concentratio indicated in this record is
to be applied.

Text

50

Primary



ProcessUnits

This is the units associated with the process
parameter. It is typically a mass value per unit of
time. The user has been advised that the time unit
must be the same as the time unit for the calculated
emission rate.

Text

50





ProcessParam

This is the Process Parameter selected by the user
when a process based emission is to be calculated. A
process parameter is selected only in conjunction
with an emission rate (i.e. Ib/hr or grams/minute).

Text

75





ProcessParamID

FK-This is the process parameter Foreign Key which
is to be used to generate a process based emission
value. This process parameter is associated with an
emission rate with the same time denominator as
the one used for the process parameter.

Long Integer

4

Foreign



CorrPerc

PK- This is the oxygen or carbon dioxide
concentration value to which the concentration is to
be corrected for air dilution.

Double

8

Primary



Location

PK- This is the test location that the emission
concentration indicated in this record.is to be
applied.

Text

50

Primary



EmisConc

PK- This is the basic units of measurement (emission
or Concentration) to be applied to the test method
at the test location specified in this record.

Text

50

Primary



CorrAnal

PK- This is the compound (02 or C02) which should
be used to correct for dilution with air the basic
emission concentration indicated in this record.

Text

5

Primary



Table Name: tbILocation
Table Description: Sample Locations selected for this test

Field Name

Field Description

Field Type

Size

Key

Required

ACFM

This is an estimated volume rate (cubic feet per
minute) of the stack gas. This value is used in the
Test Plan Review to assess the proposed sampling
volume, time and analytical finish.

Long Integer

4





Page 38 of 54


-------
Table Name: tbILocation
Table Description: Sample Locations selected for this test

Field Name

Field Description

Field Type

Size

Key

Required

VdwnStreamDist

For ducts less than 12 inches in diameter, this is the
distance in inches to the nearest downstream
(toward the exit point or with the gas flow)
disturbance in the gas flow.

Long Integer

4





Controlled

This check box field indicates whether this location
is after a control device which would affect the
emissions.

Yes/No

1





AssumedMoisturePct

This is an estimated moisture of the stack gas. This
value is used in the Test Plan Review to assess the
proposed sampling volume, time and analytical
finish.

Single

4





AssumedStack02Pct

This is an estimated oxygen concentration of the
stack gas. This value is used in the Test Plan Review
to assess the proposed sampling volume, time and
analytical finish.

Single

4





InletOutlet

This check box field indicates whether this location
is before or after a control device which would
affect the emissions.

Text

50





NPTraverse

This check box field indicates whether the sampling
methodologies used for this test location are for a
pollutant that is particulate form or is a gas or vapor
form.

Yes/No

1





VUpStreamDist

For ducts less than 12 inches in diameter, this is the
distance in inches to the nearest upstream (toward
the emission source or counter to the gas flow)
disturbance in the gas flow.

Long Integer

4





NumPoints

This is the number of sample collection points. This
value can be calculated by the ERT based upon the
diameter (equivalent diameter), the upstream
distance, the downstream distance and the type of
traverse (particulate or non particulate).

Long Integer

4





DuctDiam

If the test location is a circular duct or stack, the
tester or facility will provde the diameter of the duct
in inches in this field. This field will be blank if the
duct or stack is rectangular.

Double

8





Temp

This is an estimated temperature (F) of the stack
gas. This value is used in the Test Plan Review to
assess the proposed sampling volume, time and
analytical finish.

Long Integer

4





Location

PK- RF- This is the name of the test location as
entered by the source tester or facility

Text

50

Primary

Req.

Page 39 of 54


-------
Table Name: tbILocation
Table Description: Sample Locations selected for this test

Field Name

Field Description

Field Type

Size

Key

Required

DuctLength

If the test location is a rectangular duct or stack, the
tester or facility will provde the length of the duct in
inches in this field. This field will be blank if the duct
or stack is circular.

Double

8





DuctWidth

If the test location is a rectangular duct or stack, the
tester or facility will provde the width of the duct in
inches in this field. This field will be blank if the duct
or stack is circular.

Double

8





EquivDiam

If the test location is a rectangular duct or stack and
both the duct length and width is available, the
equivalent diameter of the duct will be calculated
using equation Equation 1-1 in Section 12.2 of
Method 1 and entered in this field.

Double

8





UpStreamDist

This is the distance in inches to the nearest
upstream (toward the emission source or counter to
the gas flow) disturbance in the gas flow.

Double

8





NumTravPorts

This is the number of access holes (Ports) in the duct
or stack which are available to insert the sampling
equipment.

Long Integer

4





DwnStreamDist

This is the distance in inches to the nearest
downstream (toward the exit point or with the gas
flow) disturbance in the gas flow.

Double

8





TestPlanID

FK- This number provides a link to tbltestplan.

Long Integer

4

Foreign



Table Name: tbIMethodParams
Table Description: Methods and Target Parameters selected for this test

Field Name

Field Description

Field Type

Size

Key

Required

Group

8/11/11 keeps islSO for custom methods

Text

10





Comments

This is a comment by the user on the proposed
performance of the test method at the test location.

Memo

0





Molwt

This is the molecular weight of the custom pollutant
identified by the user. This field was added
10/10/11.

Double

8





CAS

This is the CAS Registry Number provided by the
user for custom pollutants.The number is a unique
identifier assigned by Chemical Abstracts Service
(CAS) to every chemical substance. It was added
8/5/11

Text

40





Page 40 of 54


-------
Table Name: tbIMethodParams
Table Description: Methods and Target Parameters selected for this test

Field Name

Field Description

Field Type

Size

Key

Required

LbHrLimit

added 5/13/11 for outlet QA calculations -10/29/12
not used, now with emisconc

Double

8





Compliance

added 9/29/05 - Yes/No/Indeterminate - says if it
demonstrates compliance or not

Text

20





TestRunDuration

This is the proposed sampling duration for the test
method at the test location.

Long Integer

4





NumTestRuns

This is the number of test runs of the test method
which are proposed for the test series at the test
location.

Long Integer

4





TestMethod

PK- RF- This is the test method which will be used to
quantify the target pollutant at the sample location.

Text

50

Primary

Req.

TargetPoll

PK- RF- This is the pollutants which is intended to be
measured during the test program.

Text

50

Primary

Req.

TestPlanID

FK- This number provides a link to tbltestplan.

Long Integer

4

Foreign



Location

PK- RF- This is the sample location as entered in the
"Location" area of the test plan.

Text

50

Primary

Req.

NumSampPoints

This is the number of samplng points which were
identified in the test plan sampling location page.

Long Integer

4





Table Name: tbIProcessParams
Table Description: Target Process Parameters selected for this test

Field Name

Field Description

Field Type

Size

Key

Required

ACTION

RF- This is the action performed on the process
material (for example the term "Burned" in "Tons of
Coal Burned per hour") Added 1/16/07 for EF factor

Text

20



Req.

UDesc

This is user comments which are entered on the SCC
selection tab. Added 1/23/06 How they came up
with the U factor

Memo

0





Poll Unit

RF- This is the combination of the Pollutant Units of
emission per Time Unit and is present only for
Process Parameter ID number 1. Added 1/23/06

Text

25



Req.

TimeUnit

RF- This is the unit of time for the emissions
measurement (for example the term "hour" in
"Tons of Coal Burned per hour"). For consistency
user is told to select the same process paramete
time units as the calculated emission time units.
Added 1/23/06

Text

25



Req.

Page 41 of 54


-------
Table Name: tbIProcessParams
Table Description: Target Process Parameters selected for this test

Field Name

Field Description

Field Type

Size

Key

Required

POLLJJNIT

RF- This is the mass units of measurement for the
pollutant emissions. Added 1/16/07 for EF factor

Text

10



Req.

U

added 1/23/06 +/- U factor This field does not
appear in the current "Permit/SCC" tab of the Test
Plan.

Long Integer

4





MATERIAL

RF- This is the name of the process material
described in the parameter (for example the term
"Coal" in "Tons of Coal Burned per hour"). Added
1/16/07 for EF factor

Text

40



Req.

TargetLow

The Target Low is the lower bound value of the
expected range for the Units of Measure of Process
Parameter.

Double

8





MEASURE

RF- This is the process parameter measurement unit
(eg. the term "Tons" in "Tons of Coal Burned per
hour"). In an emission factor or a process based
emission value, the measure rate is divided into the
pollutant mass rate. Added 1/16/07 for EF factor

Text

35



Req.

ProcessParamID

PK- This is the numerical sequence of the process
parameters. The value 1 is assigned to the process
parameter associated with the SCC. When the SCC
has existing default parameters the parameters in
the first record are set.

AutoNumber

4

Primary



comments

This is user comments which are entered on the
Process Parameter tab.

Memo

0





TargetValue

The Target Value is the upper bound value of the
expected range for the Units of Measure of Process
Parameter.

Double

8





UOM

This is the "Unit of Measure" for the Process
Material. It is the combination of the "Measure" for
the Process parameter (typically weight, energy or
volume) per the a "Time Unit" (for example Tons per
hour, cubic feet per hour).

Text

50





Target Pa ram

The Target Parameter is shown on the SCC selection
tab and is the default denominator for the Emission
Factor associated with the SCC. It is presented on
the first line of the Process Data area as the
combination of the Material and Action.

Double

8





Name

The Name is a concatenation of the Material and
Action (for example Coal Burned)

Text

75





TestPlanID

FK- This number provides a link to tbltestplan.

Long Integer

4

Foreign



Page 42 of 54


-------
Table Name: tbIProcessParams
Table Description: Target Process Parameters selected for this test

Field Name

Field Description

Field Type

Size

Key

Required

see

This is the SCC which is selected on the SCC tab from
a multi stage drop down list and is only present for
Process Parameter ID number 1. Added 1/23/06

Text

11





Table Name: tbIRegs
Table Description: Regulatory Limit Data

Field Name

Field Description

Field Type

Size

Key

Required

Compliance

not used

Text

25





ProcessUnits

not used

Text

50





ProcessParam

not used

Text

75





Part_SubPart

This is text from a drop down list of 40CFR60 and
40CFR63 regulations.

Text

30





ProcessParamID

not used

Long Integer

4





Limit

This field is the numerical value for the regulatory
limit for the compound and units of measure
selected by the user.

Double

8





RegDesc

This is text provided by the user to describe either
supplementary information providing more detail
than the citation of the regulation or providing the
regulatory citation and details of an applicable
regulation for a non part 60 or 63 regulation.

Text

150





Unit

This is text from a drop down list of emissions units
for compounds which were previously entered by
the selection in the test methods and
concentrations area.

Text

50





Compound

This is text from a drop down list of compounds
which were previously entered by the selection in
the test methods and concentrations area.

Text

50





Table Name: tbIProcessLab
Table Description: Process Parameter Lab Data

Field Name

Field Description

Field Type

Size

Key

Required

ProcessLabID

PK- This is the numerical identifier for the Process
Lab Parameter.

AutoNumber

4

Primary



TestPlanID

FK- This number provides a link to tbltestplan.

Long Integer

4

Foreign



Page 43 of 54


-------
Table Name: tbIProcessLab
Table Description: Process Parameter Lab Data

Field Name

Field Description

Field Type

Size

Key

Required

Name

This is the name of the Process Lab Parameter

Text

75





UOM

This is the unit of measure for the parameter.

Text

15





comments

This is a comment on the process parameter or unit
of measure.

Memo

0





Table Name: tbIAPCDParams
Table Description: Air Pollution Control Devices

Field Name

Field Description

Field Type

Size

Key

Required

tbIAPCDParamID

PK- This is the numerical identifier for this air
pollution control device.

AutoNumber

4

Primary



ptb

This is used for backward compatibility with old
project data sets and is not used now.

Text

50





comments

This is a comment field for the user to provide more
details on the design or operation of the air
pollution control or the Target Parameter used to
characterize the controls performance.

Memo

0





TargetValue

This is the pre test prospective value of the target
parameter in the units of measure which is
expected to be achieved during the emission test.

Double

8





UOM

This is the units of measure for the target parameter
identified in UOM.

Text

50





Target Pa ram

This is the name of an operating parameter which
provides an indication of the effectiveness of the
operation of the identified control device.

Double

8





TestPlanID

FK- This number provides a link to tbltestplan.

Long Integer

4

Foreign



location

FK- This is the test location which the named APDC
is associated.

Text

50

Foreign



APCDName

RF- This is the text identifier of one or more general
installed air pollution control devices. The user may
select one of the standard control devices in
apptblContoEquip or another name of a control not
on that list.

Text

75



Req.

Page 44 of 54


-------
Table Name: tbIAPCDRunData
Table Description: Air Pollution Control Device run data

Field Name

Field Description

Field Type

Size

Key

Required

Comment

This is a text field for additional run specific
information on the operation of the control device
or the measured parameter value.

Memo

0





Value

This is the numerical value of the process variable
identivied in tbIAPCDParams.

Double

8





APCDParamID

PK- This is the numerical identifier as indicated in
tbIAPCDParams for this air pollution control device.
It is a link to tbIAPCDParams

Long Integer

4

Primary



Run

PK- This is the numerical identifier for the process
run number for the measured value. The run
numbers used would be associated with the test
runs.

Long Integer

4

Primary



Table Name: tbIAttachments
Table Description: Attached documents to support this test

Field Name

Field Description

Field Type

Size

Key

Required

keep

This is used for backward compatibility with old
project data sets and is not used now.

Yes/No

1





Attach ID

PK- This is an ID number for the description of the
attachments for the test report. Attachment ID
numbers below 50 are used for established fixed
documentation areas. Attachment ID numbers
above 50 are supplementary types provided by the
user.

AutoNumber

4

Primary



TestPlanID

FK- This number provides a link to tbltestplan.

Long Integer

4

Foreign



Attach Desc

This is a description of the type of documentation
filed in the area covered by these attachments.
Descriptions for ID numbers below 50 are set and
not changeable.

Text

120





Filename

This is used for backward compatibility with old
project data sets and is not used now.

Text

100





xfile

This field has an indicator of the number of
attachments in this record. When selected, this field
opens a menu which contains the names of the files
that the user attached to the documentation area
described in AttachDesc.

Attachment

4





Page 45 of 54


-------
Table Name: tbICyllnv
Table Description: Inventory of test gas cylinders

Field Name

Field Description

Field Type

Size

Key

Required

CertDate

This is the date which the gas provider certified the
concentration of the gas contained in the cylinder.

Date/Time

8





UncertainPercent

This is the uncertainty associated with the
certification value for the gas. It may be the
required uncertainty for the specific procedure or a
value assigned by the vendor.

Double

8





CertValue

This is the numerical value of the concentration of
the gas contained in the cylinder. This value will be
used by the ERT to compare with the measured
values during calibration.

Double

8





CertProcedure

This is the certification procedure used by the gas
provider to verify the concentration of the gas in the
cylinder and indicated in the provided paperwork.

Text

50





CylID

PK- This is a unique identifier provided for the
specific calibration gas cylinder and gas. EPA
guidance is to use the cylinder ID on the gas
certificate supplemented by the specific gas
identifier for multicomponent gasses.

Text

50

Primary



ExpDate

This is the date which the certification expires on
the certificate of the concentration of the gas
contained in the cylinder.

Date/Time

8





Compound(Analyte)

This is the specific gas compound for which this
certified value will be used to calibrate an
instrument.

Text

50





Table Name: tbIProcessLabRun
Table Description: Process Parameter Lab Run Data

Field Name

Field Description

Field Type

Size

Key

Required

Comment

This is a comment on the process parameter
collection, measurement or analysis.

Memo

0





Value

This is the value in the units of measure described in
the test plan record.

Double

8





Run

PK- This is the Run number for the Process Lab
analysis.

Long Integer

4

Primary



ProcesslabID

PK- This is the Process Lab ID which this record is
one of the runs. It provides a link to
tbIProcessParams

Long Integer

4

Primary



Page 46 of 54


-------
Table Name: tbIProcessRunData
Table Description: Process Parameter Run Data

Field Name

Field Description

Field Type

Size

Key

Required

ProcessParamID

PK- This is the numerical Process Parameter ID
assigned in the Process Parameter during the
preparation of the Test Plan. Links to
tbIProcessParams

Long Integer

4

Primary



Run

PK- This is the numerical Run number for the
Process Parameter. For Emission Factor
development and for process parameter based
emissions, the process parameter runs are
associated with emission test runs.

Long Integer

4

Primary



Value

This is the numerical value for the rate which the
Action on the Process Parameter is occuring during
the run.

Double

8





Comment

This is user comments on the some aspect of
process parameter run.

Memo

0







Table Name: tbIComments
Table Description: Observer, Test Reviewer, and Tester Comments

Field Name

Field Description

Field Type

Size

Key

Required

FieldID

PK- This is the field name for the type of comment.
Currently there are three fields which are available
for users or reviewers to provide comments on the
overall test report. These are Observer (State
agency), Test Reviewer (test company) and Tester.

Text

50

Primary



Comment

This is the text provided by the user identified in
FieldID.

Memo

0





Table Name: tbIStateQA
Table Description: Regulatory Test Plan Review Data

Field Name

Field Description

Field Type

Size

Key

Required

TesterComments

This is used for backward compatibility with old
project data sets and is not used now.

Text

5





EPASampleAuditYN

This check box is used by State agency reviewers to
indicate whether the information provided in the
test plan Audit Samples area (12) is acceptable,
requires revision or is not applicable for the test
plan.

Text

5





Page 47 of 54


-------
Table Name: tbIStateQA
Table Description: Regulatory Test Plan Review Data

Field Name

Field Description

Field Type

Size

Key

Required

EqupCalibrationYN

This check box is used by State agency reviewers to
indicate whether the information provided in the
test plan Equipment Calibration area (13) is
acceptable, requires revision or is not applicable for
the test plan.

Text

5





CalibGasCertifiedYN

This check box is used by State agency reviewers to
indicate whether the information provided in the
test plan Calibration Gas Certification area (14) is
acceptable, requires revision or is not applicable for
the test plan.

Text

5





DilutionProposedYN

This check box is used by State agency reviewers to
indicate whether the information provided in the
test plan Dilution probe area (15) is acceptable,
requires revision or is not applicable for the test
plan.

Text

5





Gas

This check box is used by State agency reviewers to
indicate whether the information provided in the
test plan Calibration Gas list area (16) is acceptable,
requires revision or is not applicable for the test
plan.

Text

5





TestSchedule

This check box is used by State agency reviewers to
indicate whether the information provided in the
test plan Test Schecule area (17) is acceptable,
requires revision or is not applicable for the test
plan.

Text

5





Comments

This check box is used by State agency reviewers to
indicate whether the information provided in the
test plan Additional Comments area (18) is
acceptable, requires revision or is not applicable for
the test plan.

Text

5





FacRepName

This check box is used by State agency reviewers to
indicate whether the information provided in the
test plan Facility Review Signature area is
acceptable, requires revision or is not applicable for
the test plan.

Text

5





TestRepName

This check box is used by State agency reviewers to
indicate whether the information provided in the
test plan Test Company Review Signatue area is
acceptable, requires revision or is not applicable for
the test plan.

Text

5





OxygenConcDet3or3a

This check box is used by State agency reviewers to
indicate whether the information provided in the
test plan Molecular Weight determination area (11)
is acceptable, requires revision or is not applicable
for the test plan.

Text

5





Page 48 of 54


-------
Table Name: tbIStateQA
Table Description: Regulatory Test Plan Review Data

Field Name

Field Description

Field Type

Size

Key

Required

AgencyComments

This is used for backward compatibility with old
project data sets and is not used now.

Text

5





Target Pa ram

This check box is used by State agency reviewers to
indicate whether the information provided in the
test plan Sampling Method, Pollutants measured,
test runs and durating area is acceptable, requires
revision or is not applicable for the test plan.

Text

5





Attachments

This check box is used by State agency reviewers to
indicate whether the information provided in the
test plan Attachments area is acceptable, requires
revision or is not applicable for the test plan.

Text

5





PPE

This check box is used by State agency reviewers to
indicate whether the information provided in the
test plan Personal Protective Equipment area (19) is
acceptable, requires revision or is not applicable for
the test plan.

Text

5





Process

This check box is used by State agency reviewers to
indicate whether the information provided in the
test plan Process area (4a) is acceptable, requires
revision or is not applicable for the test plan.

Text

5





TestPlanID

PK- This number provides a link to tbltestplan.

Long Integer

4

Primary



FacName

This check box is used by State agency reviewers to
indicate whether the information provided in the
test plan Facility Information area is acceptable,
requires revision or is not applicable for the test
plan.

Text

5





TestCoName

This check box is used by State agency reviewers to
indicate whether the information provided in the
test plan Test Company Information area is
acceptable, requires revision or is not applicable for
the test plan.

Text

5





PermittedSourcelD

This check box is used by State agency reviewers to
indicate whether the information provided in the
test plan Permit and Source ID area is acceptable,
requires revision or is not applicable for the test
plan.

Text

5





TestPurpose

This check box is used by State agency reviewers to
indicate whether the information provided in the
test plan Purpose area (1) is acceptable, requires
revision or is not applicable for the test plan.

Text

5





Page 49 of 54


-------
Table Name: tbIStateQA
Table Description: Regulatory Test Plan Review Data

Field Name

Field Description

Field Type

Size

Key

Required

MeetMinReqYN

This check box is used by State agency reviewers to
indicate whether the information provided in the
test plan Method 1 Acceptability area (9) is
acceptable, requires revision or is not applicable for
the test plan.

Text

5





OtherRegPurposeDes
c

This check box is used by State agency reviewers to
indicate whether the information provided in the
test plan Other Regulatorty Purposes area (3) is
acceptable, requires revision or is not applicable for
the test plan.

Text

5





CyclonicFlowYN

This check box is used by State agency reviewers to
indicate whether the information provided in the
test plan Cyclonic flow area (10) is acceptable,
requires revision or is not applicable for the test
plan.

Text

5





ProcessLab

This check box is used by State agency reviewers to
indicate whether the information provided in the
test plan Process Lab area (4b) is acceptable,
requires revision or is not applicable for the test
plan.

Text

5





SourceDesc

This check box is used by State agency reviewers to
indicate whether the information provided in the
test plan Source Description area (5a) is acceptable,
requires revision or is not applicable for the test
plan.

Text

5





APCD

This check box is used by State agency reviewers to
indicate whether the information provided in the
test plan Air Pollution Control Device area (5b) is
acceptable, requires revision or is not applicable for
the test plan.

Text

5





Location

This check box is used by State agency reviewers to
indicate whether the information provided in the
test plan Sampling Location area (6) is acceptable,
requires revision or is not applicable for the test
plan.

Text

5





EmisCon

This check box is used by State agency reviewers to
indicate whether the information provided in the
test plan Emissions Concentrations area (7b) is
acceptable, requires revision or is not applicable for
the test plan.

Text

5





TestlnAccordanceDes
c

This check box is used by State agency reviewers to
indicate whether the information provided in the
test plan Alternative Methods area (8) is acceptable,
requires revision or is not applicable for the test
plan.

Text

5





Page 50 of 54


-------
Table Name: tbIStateQA
Table Description: Regulatory Test Plan Review Data

Field Name

Field Description

Field Type

Size

Key

Required

ApplRegs

This check box is used by State agency reviewers to
indicate whether the information provided in the
test plan Applicable Regulations area (2) is
acceptable, requires revision or is not applicable for
the test plan.

Text

5





Table Name: tbIStateQACmts
Table Description: Regulatory Test Plan Review Comments

Field Name

Field Description

Field Type

Size

Key

Required

Accepted

This field is the result of the acceptability check box
for the area described by the Field ID. PAUL -1
selected Yes, No and N/A and there was no change
in the values shown in the "Accepted" field.

Text

1





Comment

This field is the comments by the State Agency
Reviewer on the area described by the Field ID.

Memo

0





SortID

This is the sequence number for the Field ID.

Long Integer

4





testPlanID

FK- This number provides a link to tbltestplan.

Long Integer

4

Foreign



TestPlanSection

This is the alphanumeric ID for the test plan area
which the record associated with thid field ID covers.

Text

30





FieldID

This is text describing the area of the test plan which
the record associated with this field ID covers.

Text

30





Table Name: apptblQAQs
Table Description: Table that holds the Quality Assurance Questions used for the test report

Field Name

Field Description

Field Type

Size

Key

Required

Nval

Value for No answer

Long Integer

4





AnsField

field to check

Text

255





ERTCheck

calculation for answering ERT questions

Text

255





RefrLink

link to web reference

Hyperlink

0





Page 51 of 54


-------
Table Name: apptblQAQs
Table Description: Table that holds the Quality Assurance Questions used for the test report

Field Name

Field Description

Field Type

Size

Key

Required

Data Link

link to data in ERT

Text

255





DataType

Attach=attachment; Qry = query; frm = Form;....
used with Showdata to show data related to the
question

Text

10





SortID

master question number

Double

8





RevType

Review type (ERT or 3rd Party)

Text

10





AnsTable

table to check

Text

255





Y2val

Value to add if ERT ans is no and 3rd ans is yes. on
yes, adds to yes value

Long Integer

4





Yval

Value for Yes answer

Long Integer

4





Question

Question

Memo

0





LinkID

links Reg to Completeness

Long Integer

4





QID

Unique ID for this record

Long Integer

4





QuestType

Question type: All; Manual Test Method (MTM);
Instrumental Test Method (ITM); Lab; Other (OTH)

Text

10





Table Name: tbIQAQAns
Table Description: Quality Assurance Question Answers

Field Name

Field Description

Field Type

Size

Key

Required

Comment

Ths is a text field which the reviewer may provide
comments with respect to the review of the area
described by the quality assessment question.

Memo

0





QID

PK- This is the ID number of the quality assessment
question.

Long Integer

4

Primary



Answer

This is a drop down response for the reviewers
assessment on whether the available
documentation demonstrates that the test meets
the required specifications for the question area.
Available responses include Blank (no selection),
Yes, No and N/A.

Text

5





Page 52 of 54


-------
Table Name: tbIEFLink
Table Description: Table for the Emission Factor Export

Field Name

Field Description

Field Type

Size

Key

Required

xtbl

This is the table record which should be used to
calculate the basic emission rate in pounds per hour
and which should be divided by the process rate
documented in the process run indicated in this
record. tbIRunDatalTM; tbIRunHeader

Text

20





Location

This is the test location that the emission
concentration indicated in this record.is to be
applied.

Text

50





Method

This is the test method at this test location that the
emission concentratio indicated in this record is to
be applied.

Text

20





RunNumber

This is the Emission Test Method run number for the
location which this record represents.

Text

20





see

This is the SCC for which this test record represents,
added 1/23/06

Text

11





Run

This is the primary or initial process run number for
which this record represents

Long Integer

4





Table Name: tbISubmitActions
Table Description: Project Data Set Submittal History

Field Name

Field Description

Field Type

Size

Key

Required

Comment

This is a comment field where the submitting
individual may provide supplementary information
to the recipient about the Project Data Set or
submission report.

Memo

0





SubmittedFrom Email

This is the email address of the individual that is
preparing the Project Data Set file for transmittal..

Text

50





SubmittedFrom

This is the name of the individual that is submitting
the Project Data Set.

Text

50





SubmittedToEmail

This is the email address (if known) of the individual
to whom the Project Data Set file is being sent.

Text

50





SubmittedTo

This is the name of the person or system to whom
the user is submitting the Project Data Set.

Text

50





SubmitDate

This is the date that the user processed the Project
Data Set for submission to the next individual.

Date/Time

8





ID

PK- This is the unique key for this record.

AutoNumber

4

Primary



Page 53 of 54


-------
Table Name: tbISubmitActions
Table Description: Project Data Set Submittal History

Field Name

Field Description

Field Type

Size

Key

Required

PkgName

This is the file name which the ERT assigns to the
Project Data Set package. It consists of the Facility
Name followed by the date and time that the ERT
created the file.

Text

255





Action

This is one of a limited list of possible actions which
the current user may select. The actions include but
are not limited to Submit (or Resubmit) Test Plan (or
Report), Approve Test Plan (or Report), Notice of
Deficiency (Test Plan or Test Report).

Text

50