DRAFT
ECMPS Emissions
Check Specifications
United States Environmental Protection Agency
Office of Air and Radiation
Clean Air Markets Division
Ariel Rios Building
1200 Pennsylvania Avenue
Washington, DC 20460
June 17, 2015
-------
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
Table of Contents
Appendix D and E Status
1
Daily Calibration Status
35
Daily Calibration Test
47
Daily Emissions Data
99
Daily Interference Status
115
Daily Test
122
EM Weekly System Integrity Test
129
EM Weekly Test Summary
140
Flow-to-Load Status
150
Hourly Aggregation
163
Hourly Appendix D
210
Environmental Protection Agency
Page 850 of 850
-------
Hourly Appendix E 272
Hourly Apportionment 288
Hourly Calculated Data 305
Hourly Derived Data 365
Hourly General 433
Hourly Monitor Data 465
Hourly Operating Data 521
Leak Status 575
Linearity Status 584
LME 611
MATS Calculated Hourly Value Checks 664
MATS Derived Hourly Value Checks 691
MATS Hourly GFM Data 711
MATS Monitor Hourly Value Checks 721
MATS Operating Hour Checks 745
MATS Sampling Train Checks 765
MATS Sorbent Trap Data 787
RATA Status 806
Weekly System Integrity Status 845
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Category:
Appendix D and E Status
Environmental Protection Agency
Page 1 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: ADESTAT-1
Check Name: Determine Appendix E Status
Related Former Checks:
Applicability:
Description:
Validation Tables:
Fuel Code (Lookup Table)
Specifications:
Set PriorAppendixERecord = null.
Set InvalidAppendixERecord = null.
Set CurrentAppendixEStatus = null.
Set PriorAppendixEEventRecord = null.
Set SubsequentAppendixERecord = null
Set AppendixEMissingOpDatalnfo = null.
ff (App E Op Code in set {N, W, X, Y, Z} ) AND AppE NOXE System ID is not null)
Append AppE NOXE System ID to NOXE System ID Array.
Locate the most recent record in AppendixETestRecordsByLocationForQAStatus for the location where the SystemID is equal to
the AppE NOXE System ID and the TestResultCode is not equal to "INVALID" and the EndDate/Hour is prior to the
CurrentOperatingDate/Hour.
if (AppendixETestRecordsByLocationForQAStatus is found)
Set Prior AppendixERecord = the found record in AppendixETestRecordsByLocationForQAStatus.
Locate the most recent record in AppendixETestRecordsByLocationForQAStatus for the location where the SystemID is
equal to the AppENOXESystemID and the TestResultCode is equal to "INVALID" and the EndDate/Hour is prior to the
CurrentOperatingDate/Hour and the EndDate/Hour is greater than the PriorAppendixERecord.EndDate/How.
if (AppendixETestRecordsByLocationForQAStatus is found)
Set InvalidAppendixERecord = the found record in AppendixETestRecordsByLocationForQAStatus.
else
Locate the most recent record in AppendixETestRecordsHyLocationForOAStatus for the location where the SystemID is
equal to the AppE NOXE System ID and the TestResultCode is equal to "INVALID" and the EndDate/Hour is prior to the
CurrentOperatingDate/Hour.
if (AppendixETestRecordsByLocationForQAStatus is found)
Set InvalidAppendixERecord = the found record in AppendixETestRecordsByLocationForQAStatus.
if (PriorAppendixERecord is not null)
if (PriorAppenclixERecord.QANccdsE\ i\\ui\UonFh\g = "Y")
Set CurrentAppendixEStatus = "Prior Test Not Yet Evaluated",
else if (PriorAppenclbcERecorcl.TcstRcsultCodc = null)
Set CurrentAppendixEStatus = "OOC-Prior Test Has Critical Errors".
Environmental Protection Agency
Page 2 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
else
Set PriorTestExpirationDate = Prior A ppendixERecord. Tc s t E \ p i ra t i o n D a tc
if {PriorTestExpirationDate is null)
Set PriorTestExpirationDate = 5 years (20 calendar quarters) after the end of the quarter of the
PriorAppendixERecordEndDate/How.
if (CurrentOperatingDate/Hour is AFTER the PriorTestExpirationDate)
Set CurrentAppendixEStatus = "OOC-Expired".
Locate the most recent record in QACertificationEventRecords where the SystemID is equal to the
AppENOXESystemID and the RequiredTestCode is equal to 75 and the QACertEventDate/Hour is prior
to the CurrentOperatingDate/Hour and theQACertEventDate/Hour is on or after the
PriorAppendixERecordEndDate/How
if (QACertificationEventRecords is found)
Set PriorAppendixEEventRecord = the found record in QACertificationEventRecords.
if (the number of calendar days ON OR AFTER the
Prior A ppen dixEE vent Record. Q A C c rt E y e n t D a t c and ON OR BEFORE the
CurrentOperatingDate/Hour > 180)
Set CurrentAppendixEStatus = "OOC-Event".
else if {PriorAppendixEEventRecord .MinOpDaysPriorQuarter is null)
Set PriorAppendixEEventRecord .MinOpDaysPriorQuarter = 0
Set PriorAppendixEEventRecord .MaxOpDaysPriorQuarter = 0
for each quarter beginning with the quarter of the
PriorAppendixEEventRecord.QACertEymtDate and continuing through the quarter
BEFORE the CurrentOperatingDate/Hour.
if (EarliestLocationReportDate <= the last day of the quarter being checked)
Locate the record in OperatingSuppDataRecordsbyLocation where the
OpTypeCode is equal to "OPDAYS" and the reporting period is equal to
the quarter being checked.
if (OperatingSuppDataRecordsbyLocation is not found)
else
Set Prior AppendixEEventRecord.MmOpDaysPriorQuarter = -1
Set AppendixEMissingOpDatalnfo = "[YEAR] Q[QTR]"
(where [YEAR] is the year of the quarter being checked and
[QTR] is the number of the quarter being checked,
exit for.
else
If the quarter being checked is the quarter of the
PriorAppendixEEventRecord.QACertEventDate
If (()peratingSuppl)ataRecordsbyLocation.Op Va 1 lie
Environmental Protection Agency
Page 3 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
MINUS the number of calendar days in the quarter
being checked that are PRIOR to the
Prior A ppen ilixEE vent Record. Q A C c rt Ey e n t D a t c > 0)
Set
Prior A ppend'ixEEventRecord. IVI i nOp D ay s P ri o
rQuarter =
()peratingSuppI)ataRecordsby Location. Op Va 1
ue MINUS the number of calendar days in the
quarter being checked that are PRIOR to the
Prior A ppen d'ixEE ventRecord. Q A C c rt E v e n t D a
te
If (()peratingSuppl)ataRecordsbyL ocation. Op Va 1 lie is
less than the number of calendar days in the quarter
being checked that are ON OR AFTER the
Prior A ppen dixEE ventRecord. Q A C c rt Ey e n t D a t c)
Set
PriorAppendbcEEventRecord.MdxOpDdxsPrio
rQuarter =
()peratingSuppl)ataRecordsby Location. Op Va 1
ue.
else
Set
PriorAppendixEEventRecord.MaxOpDaysPrio
rQuarter = the number of calendar days in the
quarter being checked that are ON OR AFTER
the
Pr iorAppendbcEEventRecordX) ACcr[E\cn[Dt\
te.
Set
PriorAppendixEEventRecord.MmOpDaysPriorQuarter
PriorAppendixEEventRecord.MmOpDaysPriorQuarter
+ OperatingSuppDataRecordsby Location.Op\la\uc.
Set Prior A ppen d'ixEE ventRecord. IVI a \ O p D a\ s
PriorQuarter =
Prior A ppen dixEE ventRecord. IVI a \ O p D ay s P ri o rQ ua rtc r
+ OperatingSuppDataRecordsbyLocation. Op V alue.
If (CurrentAppendixEStatus does NOT begin with "OOC")
if (Rpt Period Op Time Accumulator Array for the Location == -1)
set CurrentAppendixEStatus = "Invalid Op Data"
elseif (PriorAppendixEEventRecord.MlnOpDnysPvlorQuiwlcr == -1)
set CurrentAppendixEStatus = 'Missing Op Data"
else if (PriorAppendbcEEventRecord.M\nOpDi\xsPriorQiVc\r[cr + Rpt Period Op Days
Environmental Protection Agency
Page 4 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Accumulator Array for the Location >30)
Set CurrentAppendbcEStatus = "OOC-Event".
else if (PriorAppendixEEventRecord.MaxOpDaysPnorQuarter + Rpt Period Op Days
Accumulator Array for the Location >30)
Set CurrentAppendbcEStatus = "Undetermined-Event".
else
Set CurrentAppendbcEStatus = "IC".
else
Set CurrentAppendbcEStatus = "IC".
if (AppEFuelCode is not equal to "MIX")
Locate the earliest record in AppendbcETestRecordsByLocationForQAStatus for the location where the SystemID
is equal to the AppENOXESystemID and the TestResultCode is not equal to "INVALID" and the EndDate/Hour is
on or after the CurrentOperatingDate/Hour
if (AppendbcETestRecordsByLocationForQAStatus is found)
Set SubsequentAppendbcERecord = the found record in
AppendbcETestRecordsByLocationForQAStatus.
Locate the earliest record in AppendbcETestRecordsByLocationForQAStatus for the location where the
SystemID is equal to the AppENOXESystemID and the TestResultCode is equal to "INVALID" and the
EndDate/Hour is on or after the CurrentOperatingDate/Hour and the EndDate/Hour is before the
SubsequentAppendbcERecord.EndDatefHom:
if (AppendbcETestRecordsByLocationForQAStatus is found)
Set InvalidAppendbcERecord = the found record in
AppendbcETestRecordsByLocationForQAStatus.
Locate the earliest record in OperatingSuppDataRecordsbyLocation where the FuelCode is equal to
AppEFuelCode and the OpTypeCode is equal to "OPHOURS"
If OperatingSuppDataRecordsbyLocation is found)
Set FuelOpSuppDataRecord = the found record in OperatingSuppDataRecordsbyLocation
Set DateFuelFirstCombusted = end date of quarter of the FuelOpSuppDataRecord .RptPeriodID -
int((FuelOpSuppDataRecord .OpValue -1)/24) days
if (If OperatingSuppDataRecordsbyLocation is found AND DateFuelFirstCombusted is more than 180
calendar days before the CurrentOperatingDate/Hour)
Set CurrentAppendbcEStatus = "OOC-No Prior Test"
else
Locate the record in the FuelCode lookup table where the FuelCode is equal to AppEFuelCode
Locate the record in FuelRecordsByHour Location for the hour and location where the FuelCode
Environmental Protection Agency
Page 5 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
is equal to the FuelCode.UnitFuclCodc
if (FuelRecordsByHourLocation is not found OR more than one FuelRecordsByHourLocation
is found)
Set CurrentAppendbcEStatus = "Invalid Location Fuel"
else if (FuelRecordsByHourLocation.lndicatorCode is equal to "S",
if (SubsequentAppendixERecord.QANQQdsEvaluationFlag = "Y")
Set CurrentAppendbcEStatus = "Subsequent Test Not Yet Evaluated",
else if (Su b sequent A ppen dlxERecord. Tc s t R c s u 11C o dc = null)
Set CurrentAppendbcEStatus = "OOC-Subsequent Test Has Critical Errors".
else
Set CurrentAppendbcEStatus = "IC"
Set PriorAppendbcERecord = SubsequentAppendixERecord
else
Set CurrentAppendbcEStatus = "OOC-No Prior Test"
else
Set CurrentAppendbcEStatus = "OOC-No Prior Test"
Locate the earliest record in AppendixETestRecordsByLocationForQAStatus for the location where the
SystemID is equal to the AppENOXESystemID and the TestResultCode is equal to "INVALID" and the
EndDate/Hour is on or after the CurrentOperatingDate/Hour
if (AppendbcETestRecordsByLocationForQAStatus is found)
Set InvalidAppendbcERecord = the found record in
AppendixETestRecordsByLocationForQAStatus.
else
Set CurrentAppendbcEStatus = "OOC-No Prior Test"
if (CurrentAppendbcEStatus begins with "OOC")
if (InvalidAppendbcERecord is not null)
Set CurrentAppendbcEStatus = CurrentAppendbcEStatus &
if (CurrentAppendbcEStatus does not begin with "IC")
Return result CurrentAppendbcEStatus.
Environmental Protection Agency
Page 6 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
Invalid Location
Fuel
Invalid Monitor
System
Invalid Op Data
Missing Fuel Op
Data
Missing Op Data
OOC-Event
OOC-Event*
OOC-Expired
OOC-Expired*
OOC-No Prior
Test
OOC-No Prior
Test*
OOC-Prior Test
Has Critical
Errors
OOC-Prior Test
Has Critical
Errors*
OOC-Subsequent
Test Has Critical
Errors
OOC-Subsequent
Test Has Critical
Errors*
Prior Test Not
Yet Evaluated
Subsequent Test
Not Yet
Evaluated
Undetermined-Ev
ent
Response
The Appendix E test status for MonitoringSystemID [ID] could not be determined,
because you did not report a single, valid unit fuel record for FuelCode [unitfuel] that
was active during the current hour.
The Appendix E test status for MonitoringSystemID [ID] could not be determined,
because the Monitor System record for the NOXE system has a critical error.
The Appendix E test status for MonitoringSystemID [ID] could not be determined,
because the OperatingTime in at least one Hourly Operating Data records was missing
or invalid.
The Appendix E test status for MonitoringSystemID [ID] could not be determined,
because the Op Supp Data record for OPHOURS for FuelCode [fuel] is missing for one
or more previous reporting periods. If you have submitted emissions data for prior
quarters, you should be able to retrieve these records by logging on to the EPA host.
The Appendix E test status for MonitoringSystemID [ID] could not be determined,
because the Op Supp Data record for OPDAYS is missing for
[MISSINGOPDATAINFO] (and possibly other previous reporting periods). If you
have submitted emissions data for prior quarters, you should be able to retrieve these
records by logging on to the EPA host.
You reported a QA Certification Event record for QACertEventCode [code]
QACertEventDate [eventdate] for MonitoringSystemID [ID], but you did not perform a
subsequent Appendix E test within the specified timeframe.
You reported a QA Certification Event record for QACertEventCode [code]
QACertEventDate [eventdate] for MonitoringSystemID [ID], but you did not perform a
subsequent Appendix E test within the specified timeframe. An invalid Appendix E test
was ignored.
The prior Appendix E test TestNumber [testnum] for MonitoringSystemID [ID] has
expired.
The prior Appendix E test TestNumber [testnum] for MonitoringSystemID [ID] has
expired. An invalid prior Appendix E test TestNumber [invtestnum] was ignored.
You did not report a prior Appendix E test for MonitoringSystemID [ID],
You did not report a prior Appendix E test for MonitoringSystemID [ID]. An invalid
prior Appendix E test Test Number [invtestnum] was ignored.
The applicable prior Appendix E test TestNumber [testnum] for MonitoringSystemID
[ID] has critical errors.
The prior Appendix E test TestNumber [testnum] for MonitoringSystemID [ID] has
critical errors. An invalid prior Appendix E test TestNumber [invtestnum] was ignored.
The subsequent recertification Appendix E test TestNumber [subtestnum] for
MonitoringSystemID [ID] has critical errors.
The subsequent recertification Appendix E test TestNumber [subtestnum] for
MonitoringSystemID [ID] has critical errors. An invalid Appendix E test TestNumber
[invtestnum] was ignored.
The Appendix E test status for MonitoringSystemID [ID] could not be determined,
because the applicable prior Appendix E test TestNumber [testnum] for the system has
not yet been evaluated.
The Appendix E test status for MonitoringSystemID [ID] could not be determined,
because the subsequent certification test TestNumber [subtestnum] for the system has
not yet been evaluated.
The software could not determine if the current hour was within the 30-operating day
window required to conduct another Appendix E test following QACertEventCode
[code] QACertEventDate [eventdate] for MonitoringSystemID [ID],
Severity
Critical Error Level
Critical Error Level
Critical Error Level
Critical Error Level
Critical Error Level
Critical Error Level
Critical Error Level
Critical Error Level
Critical Error Level
Critical Error Level
Critical Error Level
Critical Error Level
Critical Error Level
Critical Error Level
Critical Error Level
Critical Error Level
Critical Error Level
Critical Error Level
Environmental Protection Agency
Page 7 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
Usage:
1
Process/Category:
Emissions Data Evaluation Report — Hourly Configuration Evaluation
Conditions:
App E Checks Needed Equals true
2
Process/Category:
Emissions Data Evaluation Report NOx Emissions Rate Calculation Verification
Conditions:
App E Constant Fuel Mix Equals true
3
Process/Category:
Emissions Data Evaluation Report Hourly Fuel Flow
Conditions:
App E Constant Fuel Mix Equals false
Environmental Protection Agency
Page 8 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: ADESTAT-2
Check Name: Locate Most Recent Prior Accuracy Test
Related Former Checks:
Applicability:
Description:
Specifications:
Set Current Accuracy Status = null.
Set PriorAccuracyRecord = null.
Set InvalidAccuracyRecord = null.
Set Inappropriate Transmitter Transducer Test to false.
Locate the most recent record in AccuracyTestRecordsByLocationForQAStatus for the location where the ComponentID is equal to the
Fu el Flo i vCompon entRecord To Ch eck. C o m po nc n 11D and the TestResult is not equal to "INVALID" and the EndDate/Hour is prior to the
CurrentOperatingDate/Hour
if (AccuracyTestRecordsByLocationForQAStatusis found)
Set PriorAccuracyRecord = the found record in Accuracy TestRecordsByLocationForQAStatus.
if (Prior Accuracy Record.J cstTy pcCodc is equal to "FFACCTT" AND
FuelFlowComponentRecordToCheck.SampleAcquisitionMethod is not equal to "ORF", "NOZ", or "VEN")
Set Inappropriate Transmitter Transducer Test to true.
Locate the most recent record in AccuracyTestRecords By Location ForQAStatus for the location where the ComponentID is equal
to the FuelFlowComponentRecordToCheck. ComponentID and the EndDate/Hour is prior to the CurrentOperatingDate/Hour and
the EndDate/Hour is greater than the Prior A ccuracy Record. EndDate/Hour and the TestResult is equal to "INVALID".
if (AccuracyTestRecordsByLocationForQAStatus is found)
Set InvalidAccuracyRecord = the found record in Accuracy TestRecordsByLocationForQAStatus.
if (Prior A ccuracy Record. Q A Needs E va 1 uat io n F1 ag = "Y")
Set CurrentAccuracyStatus = "Accuracy Test Not Yet Evaluated".
else if (PriorAccuracyRecord J cstRcsultCodc is null)
Set Cur rentAccuracy Status = "OOC-Accuracy Test Has Critical Errors".
else if (Prior Accuracy Record.T cstRcsultCodc = "FAILED")
Set CurrentAccuracyStatus = "OOC-Accuracy Test Failed".
else if (Prior Accuracy Record.T cstRcsultCodc = "ABORTED")
Set CurrentAccuracyStatus = "OOC-Accuracy Test Aborted".
else
Set CurrentAccuracyStatus = "OOC-No Prior Accuracy Test"
Locate the most recent record in AccuracyTestRecords By Location ForQAStatus for the location where the ComponentID is equal
to the FuelFloti'ComponentRecordToCheck.ComponcnUD and the TestResult is equal to "INVALID" and the EndDate/Hour is
prior to the CurrentOperatingDate/Hour.
if (AccuracyTestRecordsByLocationForQAStatus is found)
Environmental Protection Agency
Page 9 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Set InvalidAccuracyRecord = the found record in AccuracyTestRecordsByLocationForQAStatus.
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Fuel Flowmeter QA Status Evaluation
Environmental Protection Agency
Page 10 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
ADESTAT-3
Check Name:
Locate Most Recent Prior Accuracy Event
Related Former Checks:
Applicability:
Description:
Specifications:
Set PriorAccuracyEventRecord = null.
If (CurrentA ccuracyStatus is null)
Locate the most recent record in QACertificationEventRecords WHERE
a) the ComponentID is equal to the FuelFlowComponentRecordToCheck.ComponentID AND
b) FFACCRequired is equal to "Y" AND
c) the QACertEventDate/Hour is prior to the CurrentOperatingDate/Hour AND
d) the QACertEventDate/Hour is after the later of the Prior Accuracy Record.EndDi\\dY\oux and the
TMojvlccwracyTtecon/.ReinstallationDate/Hour.
if (QACertificationEventRecords is found)
Set PriorAccuracyEventRecord = the found record in QACertificationEventRecords.
Set CurrentAccuracyStatus = "OOC-Event".
else
Set PriorTestExpirationDate = 5 years (20 calendar quarters) after the end of the quarter of the
Prior A ccuracyRecord. EndD ate/Hour.
if (CurrentOperatingDate/Hour is AFTER the PriorTestExpirationDate)
Set CurrentA ccuracyStatus = "OOC-Accuracy Test Expired".
else
Set PriorTestExpirationDate = 4 quarters after the end of the quarter of the later of the
Prior Accuracy Record.EndDMdHoux and the Prior A ccuracy Record. R c i n s t a 11 a t i o n D a t c/ H o u r.
Set Prior A ccuracy Record. Tc s t E \ p i ra t i o n D a t c = PriorTestExpirationDate.
If (CurrentOperatingDate/Hour is ON OR BEFORE the PriorTestExpirationDate)
Set CurrentAccuracyStatus = "IC".
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report
Fuel Flowmeter QA Status Evaluation
Environmental Protection Agency
Page 11 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: ADESTAT-4
Check Name: Determine Eligibility for Fuel Flow to Load Testing (Accuracy)
Related Former Checks:
Applicability:
Description:
Specifications:
Set FF2LAccuracyEligible = null.
Set FF2LAccuracyC1ieckDate = null.
if (CurrentA ecu racy Status is null)
Locate any record in FF2LTestRecordsByLocationForQAStatus for the location where the SystemID is equal to the
FuelFlowComponentRecordToCheck.SystemlD and the TestResult is equal to "PASSED", "EXC168H", "INPROG", or
"FAILED" and the quarter is prior to the quarter of the CurrentOperatingDate and the quarter is subsequent to the quarter of the
later of the PriorAccuracyRecord.EndDate and the Prior A ccuracy Record. R c i n s ta 11 a t i o n D a t c.
if (FF2LTestRecordsByLocationForQAStatus is found)
Set FF2LAccuracyEligible = true.
Set FF2LAccuracyCheckDate = the later of the PriorAccuracyRecord.EndDate and the
Pr iorAccuracy Record. Rci nstal lationDatc.
for each record in FuelFlowComponentRecords
if (FuelFlowComponentRecords. ComponentID is not equal to
Fu el Flo i vCompon entRecord To Ch eck. C o m po lie n 11D)
Locate the latest record in AccuracyTestRecordsHyLocationForOAStatus for the location where the
ComponentID is equal to the FuelFlowComponentRecords.ComponentID and the TestResult is equal to
"PASSED" and the quarter of the later of the EndDate and the ReinstallationDate is in the same or
adjacent quarter of the later of the PriorAccuracyRecord.EndDate and the
Prior A ccuracy Record. ReinstallationDate.
if (AccuracyTestRecordsByLocationForQAStatus is not found)
Set FF2 LAccuracy Eligible = false, and exit this check.
else
Set FF2LAccuracyCheckDate = the later of FF2LAccuracyCheckDate and the
AccuracyTestRecordsByLocationForQAStatus.EndDate and the
AccuracyTestRecordsByLocationForQAStatus.KeinstallationDate.
if (AccuracyTestRecords fly Location ForQAStcitus.TcslTxpcCodc is equal to "FFACCTT")
Locate the latest record in PEITestRecordsByLocationForQAStatus for the location
where the ComponentID is equal to the FuelFlowComponentRecords. ComponentID and
the TestResult is equal to "PASSED" and the quarter is in the same or adjacent quarter of
the later of the Prior Accuracy Record EndDate and the
Prior A ccuracy Record. ReinstallationD ate.
if (PEITestRecordsByLocationForQAStatus is not found)
Set FF2LAccuracyEligible = false, and exit this check.
else
Environmental Protection Agency
Page 12 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Set FF2LAccuracyC1ieckDate = the later of FF2LAccuracyC1ieckDate and the
PEITestRecords/iy Location ForOAStatus.EndD'Mc.
else if (PriorAccuracyTestRecord.7cs[7xpcCodc is equal to "FFACCTT")
Locate the latest record in PEITestRecordsByLocationForQAStatus for the location where the
ComponentID is equal to the FuelFlowComponentRecords.ComponentID and the TestResult is equal to
"PASSED" and the quarter is in the same or adjacent quarter of the Prior A ccuracy Record. E nd D a t c.
if (PEITestRecordsBy Location ForOAStatus is not found)
Set FF2 LAccuracy Eligible = false, and exit this check.
else
Set FF2LAccuracyC1ieckDate = the later of FF2LAccuracyC1ieckDate and the
PEFLestRecordsBy Location ForOAStatus.EndDdic.
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report
Fuel Flowmeter QA Status Evaluation
Environmental Protection Agency
Page 13 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
ADESTAT-5
Check Name:
Evaluate Fuel Flow to Load Tests (Accuracy)
Related Former Checks:
Applicability:
Description:
Specifications:
Set FF2LAccuracyBeginYear Quarter = null.
Set FF2LAccuracyEndYear Quarter = null.
Set InvalidFF2LTestNumber = null.
Set MissingFF2 LYear Quarter = null.
if {FF2LAccuracy Eligible == true)
Locate any record in FF2LTestRecordsByLocationForQAStatus for the location where the SystemID is equal to the
FuelFlowComponentRecordToCheck. SystemID and the TestResult is equal to "FAILED" and the quarter is prior to the quarter of
the CurrentOperatingDate and the quarter is subsequent to the quarter of the later of the PriorAccuracyRecord.EndDate and the
Prior A ccuracy Record. R c i n s ta 11 a t i o n D a t c.
if (FF2LTestRecordsByLocationForQAStatus is found)
Set InvalidFF2LTestNumber = FF21, TestRecordsByL ocation For OA Status. Te st N u lube r
Set CurrentAccuracyStatus = "OOC-Fuel Flow to Load Test Failed",
exit check.
Locate any record in FF2LTestRecordsByLocationForQAStatus for the location where the SystemID is equal to the
FuelFlowComponentRecordToCheck. SystemID and the TestResult is NULL and the quarter is prior to the quarter of the
CurrentOperatingDate and the quarter is subsequent to the quarter of the later of the PriorAccuracyRecord.EndDate and the
Prior A ccuracy Record. R c i n s ta 11 a t i o n D a t c.
if (FF2LTestRecordsByLocationForQAStatus is found)
Set InvalidFF2LTestNumber = FF21. TestRecordsByL ocation ForOA Status. Te st N u lube r
Set Cur rentAccuracy Status = "OOC-Fuel Flow to Load Test Has Critical Errors",
exit check.
Locate any record in FF2LTestRecordsByLocationForQAStatus for the location where the SystemID is equal to the
FuelFlowComponentRecordToCheck. SystemID and the QANeedsEvaluation flag is equal to "Y" and the quarter is prior to the
quarter of the CurrentOperatingDate and the quarter is subsequent to the quarter of the later of the PriorAccuracyRecord.EndDate
and the PriorAccuracyRecordR-QinstaAationDate.
if (FF2LTestRecordsByLocationForQAStatus is found)
Set InvalidFF2LTestNumber = FF21. TestRecordsByL ocation ForOA Status. Te st N u lube r
Set Cur rentAccuracy Status = "Fuel Flow to Load Test Has Not Yet Been Evaluated",
exit check.
Locate the earliest record in FF2LTestRecordsByLocationForQAStatus for the location where the SystemID is equal to the
FuelFlowComponentRecordToCheck.SystemlD and the TestResult is equal to "PASSED", "FEW168H", or "EXC168H" and the
quarter is prior to the quarter of the CurrentOperatingDate and the quarter is subsequent to the quarter of the later of the
PriorAccuracyRecord.EndDate and the PriorAccuracyRecordRsinsta&ationDate.
if (FF2LTestRecordsByLocationForQAStatus is found)
Set FF2LAccuracyBeginYearQuarter = FF2LTestRecordsBy Location ForOAStatus.Ycar &
FF2L TestRecordsByLocationForQAStatus. Quarter.
Environmental Protection Agency
Page 14 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
else
Set FF2LAccuracyBeginYearQuarter = null
Locate the latest record in FF2LTestRecordsByLocationForQAStatus for the location where the SystemID is equal to the
FuelFlowComponentRecordToCheck. SystemID and the TestResult is equal to "INPROG" and the quarter is prior to the quarter of
the CurrentOperatingDate and the quarter is subsequent to the quarter of the later of the Prior Accuracy Record EndDats and the
Prior A ccuracy Record. R c i n s ta 11 a t i o n D a t c.
if (FF2LTestRecordsByLocationForQAStatus is found)
if {FF2LAccuracyBeginYearQuarter is not null AND FF2/.TestRecordsByLocationForOAStatus. Ycar/Quartcr >
FF2LAccuracyBegin YearQuarter)
Set InvalidFF2LTestNumber = FF21, TestRecordsByL ocation ForOA Status. Te st N u lube r
Set CurrentAccuracyStatus = "OOC-Invalid Fuel Flow to Load Test",
exit check.
else if (FF2LTestRecordsByLocationForQAStatus.Year/Quarter is more than 4 quarters after the quarter of the
FF2LAccuracyC1ieckDate)
Set InvalidFF2LTestNumber = FF21, TestRecordsByL ocation ForOA Status. Te st N u lube r
Set CurrentAccuracy Status = "Undetermined-Baseline Period Expired",
exit check.
Set FF2LAccuracyBeginYearQuarter = the quarter after the quarter of the FF2LAccuracyCheckDate.
Locate the latest record in FF2LTestRecordsByLocationForQAStatus for the location where the SystemID is equal to the
FuelFlowComponentRecordToCheck.SystemID and the TestResult is equal to "PASSED", "EXC168H", "INPROG", or
"FEW 168H", and the quarter is prior to the quarter of the CurrentOperatingDate and the quarter is subsequent to the quarter of the
later of the Prior Accuracy Record EndDs&Q and the Prior A ecu racy Record. R c i n s ta 11 a t i o n D a t c.
Set FF21 A ccuracyEnd YearOuarter = FF2 L TestRecordsByL ocation ForQAStatus. Year &
FF21. TestRecordsBy Location ForOA Status. Q ua rtc r.
for each quarter between the FF2LAccuracyBeginYearQuarter and the FF2LAccuracyEndYearQuarter (inclusive)
Locate any record in FF2LTestRecordsByLocationForQAStatus for the location where the SystemID is equal to the
FuelFlowComponentRecordToCheck. SystemID and the quarter is equal to the quarter to check.
if (FF2LTestRecordsByLocationForQAStatus is found)
if (FF2LTestRecordsByLocationForOAStatus.TcslRcsull = "FEW168H")
Locate a record in OperatingSuppDataRecordsbyLocation where the FuelCode is equal to
CurrentFuelFlowRecord.FuelCode and the OpTypeCode is equal to "OPHOURS" or "OSHOURS" and
the quarter is equal to the quarter to check and the OpValue >= 168.
if (OperatingSuppDataRecordsbyLocation is found)
Locate any record in FF2LBaselineRecordsByLocationForQAStatus for the location where the
SystemID is equal to the FuelFlowComponentRecordToCheck. SystemID, and the EndDate is
within the quarter being checked.
If not found,
Set InvalidFF2LTestNumber =
FF2 LTestRecordsBy Location ForOAStatus.TcslNumbcr
Set CurrentAccuracyStatus = "OOC-Invalid Fuel Flow to Load Test".
Environmental Protection Agency
Page 15 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Exit check.
else
Locate a record in OperatingSuppDataRecordsbyLocation where the FuelCode is equal to
CurrentFuelFlou= 168.
if (OperatingSuppDataRecordsbyLocation is found)
Set MissingFF2 LYear Quarter equal to the year/quarter to check.
Set CurrentAccuracyStatus = "Undetermined-Missing Fuel Flow to Load Test".
Exit check.
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report
Fuel Flowmeter QA Status Evaluation
Environmental Protection Agency
Page 16 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
ADESTAT-6
Check Name:
Determine Accuracy Test Expiration Date
Related Former Checks:
Applicability:
Description:
Specifications:
Set AccuracyMissingOpDatalnfo = null,
if {CurrentAccuracy Status is null)
Set PriorTestExpirationDate = Prior A ccuracy Record. Tc st E \ p i ra t i o n Da tc.
for each quarter subsequent to the quarter of the later of the Pr iorAccuracy Record En&DMdHoux and the
Prior A ccuracy Record. Re i nsta llat ionDate/H our and prior to the quarter of the CurrentOperatingDate/Hour
Set OSO Reporter to false.
Locate a LocationReportingFrequency record for the test location where ReportingFrequencyCode = "OS", the
BeginQuarter is on or before the quarter being checked, and the EndQuarter is null or is on or after the quarter being
checked.
If found,
Set OSO Reporter to true.
if (OSO Reporter == false or the quarter to check is the 3rd quarter)
if (FF2LAccuracyEligible == true and the quarter to check is between the FF2LAccuracyBeginYearQuarter and
the FF2LA ccuracyEnd YearQuarter (inclusive))
Add 1 quarter to the PriorTestExpirationDate.
else
if (EarliestLocationReportDate > the last day of the quarter being checked)
Add 1 quarter to the PriorTestExpirationDate.
else
Locate the record in OperatingSuppDataRecordsbyLocation where the OpTypeCode is equal to
"OPHOURS" and the reporting period is equal to the quarter to check and the FuelCode is equal
to CurrentFuelFUnvRecord. FuelCode.
if (OperatingSuppDataRecordsbyLocation is not found)
Locate the record in OperatingSuppDataRecordsbyLocation where the OpTypeCode is
equal to "OPHOURS" and the reporting period is equal to the quarter to check and the
FuelCode is null.
if (OperatingSuppDataRecordsbyLocation is not found)
Set AccuracyMissingOpDatalnfo = "[YEAR] Q[QTR]" (where [YEAR] is the
year of the quarter being checked and [QTR] is the number of the quarter being
checked).
else
Environmental Protection Agency
Page 17 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Add 1 quarter to the PriorTestExpirationDate.
else if (OperatingSuppI)ataRecordsby Location.OpV'Muc <= 168)
Add 1 quarter to the PriorTestExpirationDate.
else
Locate a record in TestExtensionExemptionRecords for the location where the
ComponentID is equal to the FuelFlowComponentRecordToCheck.CompomntlD, the
reporting period is equal to the quarter to check, AND the ExtensionExemptionCode is
equal to "NONQADB".
if (TestExtensionExemptionRecords is found)
Add 1 quarter to the PriorTestExpirationDate.
else if (OSO Reporter == true and the quarter to check is the 2nd quarter)
if {FF2 LAccuracyEligible == true and the quarter to check is between the FF2LAccuracyBeginYearQuarter and
the FF2LAccuracyEndYearQuarter (inclusive))
Add 1 quarter to the PriorTestExpirationDate.
else
Locate a record in TestExtensionExemptionRecords for the location where the reporting period is equal
to the quarter to check , AND the ExtensionExemptionCode is equal to "NONQAOS" and the FuelCode is
equal to the CurrentFuelFlowRecord.Fuc\Codc.
if (TestExtensionExemptionRecords is found)
Add 1 quarter to the PriorTestExpirationDate.
else
Locate a record in TestExtensionExemptionRecords for the location where the ComponentID is
equal to the Fu el Flo i vCompon en tRecord To Ch eck .ComponentID. the reporting period is equal to
the quarter to check , AND the ExtensionExemptionCode is equal to "NONQADB".
if (TestExtensionExemptionRecords is found)
Add 1 quarter to the PriorTestExpirationDate.
else if (OSO Reporter == true and the quarter to check is the 1st or 4th quarter)
if (FF2LAccuracyEligible == true and the 2nd quarter following the quarter being checked is between the
FF2LAccuracyBeginYearQuarter and the FF2LAccuracyEndYearQuarter (inclusive))
Add 1 quarter to the PriorTestExpirationDate.
else
Locate a record in TestExtensionExemptionRecords for the location where the reporting period is equal
to the quarter to check , AND the ExtensionExemptionCode is equal to "NONQAOS" and the FuelCode is
equal to the CurrentFuelFlowRecord.Fuc\Codc.
if (TestExtensionExemptionRecords is found)
Environmental Protection Agency
Page 18 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
Add 1 quarter to the PriorTestExpirationDate.
else
Locate a record in TestExtensionExemptionRecords for the location where the ComponentID is
equal to the Fu el Flo i vCompon entRecord To Ch eck .ComponentID. the reporting period is equal to
the quarter to check , AND the ExtensionExemptionCode is equal to "NONQADB".
if (TestExtensionExemptionRecords is found)
Add 1 quarter to the PriorTestExpirationDate.
if (CurrentOperatingDate/Hour > PriorTestExpirationDate)
if (AccuracyMissingOpDatalnfo is not null)
Set CurrentAccuracyStatus = 'Missing Op Data"
Return result CurrentAccuracy Status .
else if {FF2 LAccuracy Eligible == false)
Set CurrentAccuracy Status = "OOC-Accuracy Test Expired-Fuel Flow To Load Test Ignored".
Return result CurrentAccuracyStatus.
else
Set CurrentAccuracyStatus = "OOC-Accuracy Test Expired"
else
Set CurrentAccuracyStatus = "IC-Extension"
If (CurrentAccuracyStatus does not begin with "IC" and is not null)
if (CurrentAccuracyStatus starts with "OOC" or "Undetermined" AND InvalidAccuracyRecord is not null)
Set CurrentAccuracyStatus = CurrentAccuracyStatus &
Return result CurrentAccuracyStatus.
else if (Inapprorpriate Transmitter Transducer Test == true)
Return result "Inappropriate Transmitter Transducer Test" // do NOT set current accuracy status
Environmental Protection Agency
Page 19 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
Accuracy Test
Not Yet
Evaluated
Fuel Flow to
Load Test Has
Not Yet Been
Evaluated
Inappropriate
Transmitter
Transducer Test
Missing Op Data
OOC-Accuracy
Test Aborted
OOC-Accuracy
Test Aborted*
OOC-Accuracy
Test Expired
OOC-Accuracy
Test Expired*
OOC-Accuracy
Test
Expired-Fuel
Flow To Load
Test Ignored
OOC-Accuracy
Test
Expired-Fuel
Flow To Load
Test Ignored*
OOC-Accuracy
Test Failed
OOC-Accuracy
Test Failed*
OOC-Accuracy
Test Has Critical
Errors
OOC-Accuracy
Test Has Critical
Errors*
OOC-Event
OOC-Event*
OOC-Fuel Flow
to Load Test
Failed
OOC-Fuel Flow
to Load Test
Failed*
Response Severity
The [testtype] status for [key] could not be determined, because the applicable prior Critical Error Level 1
[testtype] with TestNumber [testnum] has not yet been evaluated.
The [testtype] status for [key] could not be determined, because a prior Critical Error Level 1
fuel-flow-to-load test for MonitoringSystemID [ID] with TestNumber [ff21testnum] has
not yet been evaluated.
The prior [testtype] for [key] with TestNumber [testnum] is a transmitter/transducer Critical Error Level 2
test], but this type of test is inappropriate for the SampleAcquisitionMethodCode for the
fuel flowmeter. A transmitter/transducer test can only be performed on a NOZ, VEN,
and ORF fuel flowmeter.
The [testtype] status for [key] could not be determined, because the Op Supp Data Critical Error Level 1
record for OPHOURS, OSHOURS, or OPDAYS is missing for
[MISSINGOPDATAINFO] (and possibly other previous reporting periods). If you
have submitted emissions data for prior quarters, you should be able to retrieve these
records by logging on to the EPA host.
The applicable prior [testtype] for [key] with TestNumber [testnum] was aborted. Critical Error Level 1
The prior [testtype] for [key] with TestNumber [testnum] was aborted. An invalid prior Critical Error Level 1
[testtype] with TestNumber [invtestnum] was ignored.
The prior [testtype] for [key] with TestNumber [testnum] has expired. Critical Error Level 1
The prior [testtype] for [key] with TestNumber [testnum] has expired. An invalid prior Critical Error Level 1
[testtype] with TestNumber [invtestnum] was ignored.
The prior [testtype] for [key] with TestNumber [testnum] has expired. A prior Critical Error Level 1
fuel-flow-to-load test for MonitoringSystemID [ID] was ignored.
The prior [testtype] for [key] with TestNumber [testnum] has expired. A prior Critical Error Level 1
fuel-flow-to-load test for MonitoringSystemID [ID] was ignored. An invalid prior
[testtype] with TestNumber [invtestnum] was also ignored.
The applicable prior [testtype] for [key] with TestNumber [testnum] failed. Critical Error Level 1
The prior [testtype] for [key] with TestNumber [testnum] failed. An invalid prior Critical Error Level 1
[testtype] with TestNumber [invtestnum] was ignored.
The applicable prior [testtype] for [key] with TestNumber [testnum] has critical errors. Critical Error Level 1
The prior [testtype] for [key] with TestNumber [testnum] has critical errors. An invalid Critical Error Level 1
prior [testtype] with TestNumber [invtestnum] was ignored.
You reported a QA Certification Event record for QACertEventCode [code] Critical Error Level 1
QACertEventDate [eventdate] for [key], but you did not perform a subsequent
[testtype].
You reported a QA Certification Event record for QACertEventCode [code] Critical Error Level 1
QACertEventDate [eventdate] for [key], but you did not perform a subsequent
[testtype]. An invalid [testtype] was ignored.
The [testtype] status for [key] could not be determined, because a prior Critical Error Level 1
fuel-flow-to-load test for MonitoringSystemID [ID] with TestNumber [ff21testnum] has
failed.
The [testtype] status for [key] could not be determined, because a prior Critical Error Level 1
fuel-flow-to-load test for MonitoringSystemID [ID] with TestNumber [ff21testnum] has
failed. An invalid [testtype] with TestNumber [invtestnum] was ignored.
Environmental Protection Agency
Page 20 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
OOC-Fuel Flow
to Load Test Has
Critical Errors
OOC-Fuel Flow
to Load Test Has
Critical Errors*
OOC-Invalid
Fuel Flow to
Load Test
OOC-Invalid
Fuel Flow to
Load Test*
OOC-No Prior
Accuracy Test
OOC-No Prior
Accuracy Test*
Undetermined-Ba
seline Period
Expired
U ndetermined-Mi
ssing Fuel Flow
to Load Test
The [testtype] status for [key] could not be determined, because a prior
fuel-flow-to-load test for MonitoringSystemID [ID] with TestNumber [ff21testnum] has
critical errors.
The [testtype] status for [key] could not be determined, because a prior
fuel-flow-to-load test for MonitoringSystemID [ID] with TestNumber [ff21testnum] has
critical errors. An invalid [testtype] with TestNumber [invtestnum] was ignored.
The [testtype] status for [key] could not be determined, because one or more prior
fuel-flow-to-load tests, including the test for MonitoringSystemID [ID] with
TestNumber [ff21testnum], are invalid. These tests may be invaild because (1) the
TestResultCode indicates that baseline data collection is ongoing, yet you reported a
prior test indicating that baseline data collection was completed; or (2) the
TestResultCode indicates that there were fewer than 168 fuel QA operating hours in the
quarter, yet your emissions data for that quarter indicates otherwise.
The [testtype] status for [key] could not be determined, because one or more prior
fuel-flow-to-load tests, including the test for MonitoringSystemID [ID] with
TestNumber [ff21testnum], are invalid. These tests may be invaild because (1) the
TestResultCode indicates that baseline data collection is ongoing, yet you reported a
prior test indicating that baseline data collection was completed; or (2) the
TestResultCode indicates that there were fewer than 168 fuel QA operating hours in the
quarter, yet your emissions data for that quarter indicates otherwise. An invalid
[testtype] with TestNumber [invtestnum] was ignored.
You did not report a prior [testtype] for [key].
You did not report a valid prior [testtype] for [key]. An invalid [testtype] with
TestNumber [invtestnum] was ignored.
The [testtype] status for [key] could not be determined, because, according to the
fuel-flow-to-load test for MonitoringSystemID [ID] with TestNumber [ff21testnum],
baseline data was still being collected after the deadline.
The [testtype] status for [key] could not be determined, because a prior
fuel-flow-to-load test for MonitoringSystemID [ID] was missing for [missingff21].
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 2
Critical Error Level 1
Usage:
1
Process/Category: Emissions Data Evaluation Report ¦
¦ Fuel Flowmeter QA Status Evaluation
Environmental Protection Agency
Page 21 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
ADESTAT-7
Check Name:
Determine if Component Requires a PEI Test
Related Former Checks:
Applicability:
Description:
Specifications:
Set PEIRequired = false.
if (PriorAccuracy Record is not null and Pr iorAccuracy Record Jc${T\\ycCo(lc is equal to "FFACCTT")
Set PEIRequired = true.
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report
Fuel Flowmeter QA Status Evaluation
Environmental Protection Agency
Page 22 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
Check Code: ADESTAT-8
Check Name: Locate Most Recent Prior PEI Test
Related Former Checks:
Applicability:
Description:
Specifications:
Set CurrentPEIStatus = null.
Set PriorPEIRecord = null.
if (PEIRequired == true)
Locate the most recent record in PEITestRecordsByLocationForQAStatus for the location where the ComponentID is equal to the
FuelFlowComponentRecordToCheck.Componcn[\D and the EndDate/Hour is prior to the CurrentOperatingDate/Hour
if (PEITestRecordsByLocationForQAStatus is found)
Set Prior PEIRecord = the found record in PEITestRecordsByLocationForQAStatus.
if (7>iorP£77?ecor
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
Usage:
1 Process/Category: Emissions Data Evaluation Report Fuel Flowmeter QA Status Evaluation
Environmental Protection Agency
Page 24 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
ADESTAT-9
Check Name:
Locate Most Recent Prior PEI Event
Related Former Checks:
Applicability:
Description:
Specifications:
Set PriorPEIEventRecord = null.
If (PEI Required == true AND CurrentPEIStatus is null)
Locate the most recent record in QACertificationEventRecords WHERE
a) the ComponentID is equal to the FuelFlowComponentRecordToCheckCompomnSD AND
b) PEIRequired is equal to "Y" AND
c) the QACertEventDate/Hour is prior to the CurrentOperatingDate/Hour AND
d) the QACertEventDate/Hour is after the PriorPEIRecord. E ndDatc/Hour.
if (QACertificationEventRecords is found)
Set PriorPEIEventRecord = the found record in QACertificationEventRecords.
Set CurrentPEIStatus = "OOC-Event".
else
Set PriorTestExpirationDate = 5 years (20 calendar quarters) after the end of the quarter of the PriorPEIRecord. EndDatc.
if (CurrentOperatingDate is AFTER the PriorTestExpirationDate)
Set CurrentPEIStatus = "OOC-PEI Test Expired".
else
Set PriorTestExpirationDate = 12 quarters after the end of the quarter of the Prior PEI Record.EnADMc.
Set PriorPEIRecord.Tcst E\pi ratio nDatc = PriorTestExpirationDate.
If (CurrentOperatingDate is ON OR BEFORE the PriorTestExpirationDate)
Set CurrentPEIStatus = "IC".
If (CurrentPEIStatus starts with "OOC")
Return result CurrentPEIStatus.
Results:
Result
OOC-Event
Response
You reported a QA Certification Event record for QACertEventCode [code]
QACertEventDate [eventdate] for [key], but you did not perform a subsequent
[testtype].
The prior [testtype] for [key] with TestNumber [testnum] has expired.
Severity
Critical Error Level 1
OOC-PEI Test
Expired
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report
Fuel Flowmeter QA Status Evaluation
Environmental Protection Agency
Page 25 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Name:
Related Former Checks:
Check Code:
ADESTAT-10
Determine Eligibility for Fuel Flow to Load Testing (PEI)
Applicability:
Description:
Specifications:
Set FF2LPEIEligible = null
Set FF2LPEICheckDate = null.
if (PEIRequired == true AND CurrentPEIStatus is null)
Locate any record in FF2LTestRecordsByLocationForQAStatus for the location where the SystemID is equal to the
FuelFlowComponentRecordToCheck.Sxs{cm\D and the CalculatedTestResult is equal to "PASSED", "FEW168H", "EXC168H",
"INPROG", or "FAILED" and the Year/Quarter is prior to the quarter of the CurrentOperatingDate and the Year/Quarter is
subsequent to the quarter of the Prior PEIRecord.EndDdic.
if (FF2LTestRecordsByLocationForQAStatus is found)
Set FF2LPEIEligible = true.
Set FF2LPEICheckDate = PriorPEIRecord ALndDeWc.
for each record in FuelFlowComponentRecords
Locate the latest record in Accuracy TestRecordsIiyLocationForOAStatus for the location where the
ComponentID is equal to the FuelFlowComponentRecords. ComponentID and the TestResult is equal to
"PASSED" and the Year/Quarter of the later of the EndDate and Reinstallation Date is in the same or adjacent
quarter of the PriorPEIRecord.EndDate.
if (Accuracy TestRecordsByLoccitionForQAStcitus is not found)
Set FF2LPEIEligible = false, and exit check.
Set FF2LPEICheckDate = the later of FF2LPEICheckDate and the
AccuracyTestRecordsIiyLocationForQAStatus.^i\\ADc\\c and the
AccuracyTestRecordsByLocationForQAStatus.ReinstallationDate.
if (FuelFlowComponentRecords. ComponentID is not equal to
FuelFlowComponentRecordToCheck.Componcn[\D AND
AccuracyTestRecordsIiyLocationForOAStatus.TcslTypcCodc is equal to "FFACCTT")
Locate the latest record in PEITestRecordsByLocationForQAStatus for the location where the
ComponentID is equal to the FuelFlowComponentRecords.ComponentID and the TestResult is
equal to "PASSED" and the Year/Quarter is in the same or adjacent quarter of the
PriorPEI Record. EndD ate.
if (PEITestRecordsByLocationForQAStatus is not found)
Set FF2LPEIEligible = false, and exit check.
else
Set FF2LPEICheckDate = the later of FF2LPEICheckDate and the
PEITestRecordsBy Location ForOAStatusM\\&Dc\[c.
else
Results:
Result
Response
Severity
Environmental Protection Agency
Page 26 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
Usage:
1 Process/Category: Emissions Data Evaluation Report Fuel Flowmeter QA Status Evaluation
Environmental Protection Agency
Page 27 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Name:
Check Code:
ADESTAT-11
Evaluate Fuel Flow to Load Tests (PEI)
Related Former Checks:
Applicability:
Description:
Specifications:
Set FF2LPEIBeginYearQuarter = null.
Set FF2LPEIEndYearQuarter = null.
if (.FF2LPEIEligible == true)
Locate any record in FF2LTestRecordsByLocationForQAStatus for the location where the SystemID is equal to the
FuelFlowComponentRecordToCheck.SystQvaK) and the TestResultCode is equal to "FAILED" and the Year/Quarter is prior to the
quarter of the CurrentOperatingDate and the Year/Quarter is subsequent to the quarter of the PriorPEIRecord.EndDate.
if (FF2LTestRecordsByLocationForQAStatus is found)
Locate a record in QACertificationEventRecords WHERE
a) the ComponentID is equal to the Fu el Flo i vCompon en tRecord To Ch eck. C o m po nc n 11D AND
b) the QACertEventCode is equal to "410"
c) the RequiredTestCode is equal to "53"AND
d) the QACertEventDate/Hour is after the EndDate/Hour and of the located failed
FF2L TestRecordsByLocationForQAStatus record.
e) the QACertEventDate/Hour is prior to the CurrentOperatingDate/Hour
if (QACertificationEventRecords is not found)
Set InvalidFF2LTestNumber = FF21. TestRecordsByL ocation ForOA Status. Te st N u lube r
Set CurrentPEIStatus = "OOC-Fuel Flow to Load Test Failed".
Return result CurrentPEIStatus.
Locate any record in FF2LTestRecordsByLocationForQAStatus for the location where the SystemID is equal to the
FuelFlowComponentRecordToCheck. SystemID and the TestResultCode is NULL and the Year/Quarter is prior to the quarter of
the CurrentOperatingDate and the Year/Quarter is subsequent to the quarter of the PriorPEIRecord.EndDate.
if (FF2LTestRecordsByLocationForQAStatus is found)
Set InvalidFF2LTestNumber = FF21. TestRecordsByL ocation ForOA Status. Te st N u lube r
Set CurrentPEIStatus = "OOC-Fuel Flow to Load Test Has Critical Errors".
Return result CurrentPEIStatus.
Locate any record in FF2LTestRecordsByLocationForQAStatus for the location where the SystemID is equal to the
FuelFlowComponentRecordToCheck. SystemID and the QANeedsEvaluation flag is equal to "Y" and the Year/Quarter is prior to
the quarter of the CurrentOperatingDate and the Year/Quarter is subsequent to the quarter of the Prior PEI Record E ndDate.
if (FF2LTestRecordsByLocationForQAStatus is found)
Set InvalidFF2LTestNumber = FF21. TestRecordsByL ocation ForOA Status. Te st N u lube r
Set CurrentPEIStatus = "Fuel Flow to Load Test Has Not Yet Been Evaluated".
Return result CurrentPEIStatus.
Locate the earliest record in FF2LTestRecordsByLocationForQAStatus for the location where the SystemID is equal to the
FuelFlowComponentRecordToCheck.SystemID and the TestResultCode is equal to "PASSED", "FEW168H", or "EXC168H" and
the Year/Quarter is prior to the quarter of the CurrentOperatingDate and the Year/Quarter is subsequent to the quarter of the
PriorPEIRecord. E ndDate.
Environmental Protection Agency
Page 28 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
if (FF2LTestRecordsByLocationForQAStatus is found)
Set FF2LPEIBeginYearQuarter = FF2LTestRecordsByLocationForQAStatus.YQar &
FF2L TestRecordsByLocationForQAStatus. Quarter.
else
Set FF2LPEIBeginYearQuarter = null
Locate the latest record in FF2LTestRecordsByLocationForQAStatus for the location where the SystemID is equal to the
FuelFlowComponentRecordToCheck. SystemID and the TestResultCode is equal to "INPROG" and the Year/Quarter is prior to
the quarter of the CurrentOperatingDate and the Year/Quarter is subsequent to the quarter of the Prior PEI Record E ndDate.
if (FF2LTestRecordsByLocationForQAStatus is found)
if (Set FF2LPEIBeginYearQuarter is not null AND FF2LTestRecordsByLocationForQAStatus.Year/Quarter >
FF2LPEIBegin YearQuarter)
Set InvalidFF2LTestNumber = FF21, TestRecordsByL ocation ForOA Status. Test N u lube r
Set CurrentPEIStatus = "OOC-Invalid Fuel Flow to Load Test".
Return result CurrentPEIStatus.
else if (FF2I< TestRecordsBy Location ForOAStatus. Year/Quarter is more than 4 quarters after the quarter of the
FF2LPEICheckDate)
Set InvalidFF2LTestNumber = FF2 LTestRecordsBy Location ForOAStatus.TcsiNumbcr
Set CurrentPEIStatus = "Undetermined-Baseline Period Expired".
Return result CurrentPEIStatus.
Set FF2LPEIBeginYearQuarter to the quarter after the quarter of the FF2LPEICheckDate.
Locate the latest record in FF2LTestRecordsByLocationForQAStatus for the location where the SystemID is equal to the
Fu el Flo i vCompon entRecord To Ch eeA'. Sy s t c m ID and the TestResultCode is equal to "PASSED", "FEW168H", or "EXC168H" and
the Year/Quarter is prior to the quarter of the CurrentOperatingDate and the Year/Quarter is subsequent to the quarter of the
PriorPEIRecord. E ndDate.
Set FF2LPEIEndYearQuarter = FF2LTestRecordsByLocationForQAStatus.YQar &
FF2L TestRecordsByLocationForQAStatus. Quarter.
for each quarter between the FF2LPEIBeginYearQuarter and the FF2LPEIEndYearQuarter (inclusive)
Locate any record in FF2 LTestRecordsByLocationForQAStatus for the location where the SystemID is equal to the
FuelFlowComponentRecordToCheck. SystemID and the Year/Quarter is equal to the year/quarter to check.
if (FF2LTestRecordsByLocationForQAStatus is found)
if (FF2 LTestRecordsBy Location ForOAStatus.C'dlcuhicdTcsiRcsuh = "FEW168H")
Locate a record in OperatingSuppDataRecordsbyLocation where the FuelCode is equal to
CurrentFuelFlowRecord.FuelCode and the OpTypeCode is equal to "OPHOURS" or "OSHOURS" and
the Year/Quarter is equal to the year/quarter to check and the OpValue >= 168.
if (OperatingSuppDataRecordsbyLocation is found)
Locate any record in FF2LBaselineRecordsByLocationForQAStatus for the location where the
SystemID is equal to the FuelFlowComponentRecordToCheck.SystemID, and the EndDate is
within the quarter being checked.
Environmental Protection Agency
Page 29 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
If not found,
Set InvalidFF2LTestNumber =
FF2 LTestRecords/iy Location ForOAStatus.TcslNumbcr
Set CurrentPEIStatus = "OOC-Invalid Fuel Flow to Load Test".
Return result CurrentPEIStatus.
else
Locate a record in OperatingSuppDataRecordsbyLocation where the FuelCode is equal to
CurrentFuelFlou= 168.
if (OperatingSuppDataRecordsbyLocation is found)
Set MissingFF2 LYear Quarter equal to the year/quarter to check.
Set CurrentPEIStatus = "Undetermined-Missing Fuel Flow to Load Test".
Return result CurrentPEIStatus.
Results:
Result
Fuel Flow to
Load Test Has
Not Yet Been
Evaluated
OOC-Fuel Flow
to Load Test
Failed
OOC-Fuel Flow
to Load Test Has
Critical Errors
OOC-Invalid
Fuel Flow to
Load Test
Undetermined-Ba
seline Period
Expired
U ndetermined-Mi
ssing Fuel Flow
to Load Test
Usage:
1 Process/Category: Emissions Data Evaluation Report Fuel Flowmeter QA Status Evaluation
Response
The [testtype] status for [key] could not be determined, because a prior
fuel-flow-to-load test for MonitoringSystemID [ID] with TestNumber [ff21testnum] has
not yet been evaluated.
Seventy
Critical Error Level 1
The [testtype] status for [key] could not be determined, because a prior
fuel-flow-to-load test for MonitoringSystemID [ID] with TestNumber [ff21testnum] has
failed.
The [testtype] status for [key] could not be determined, because a prior
fuel-flow-to-load test for MonitoringSystemID [ID] with TestNumber [ff21testnum] has
critical errors.
The [testtype] status for [key] could not be determined, because one or more prior
fuel-flow-to-load tests, including the test for MonitoringSystemID [ID] with
TestNumber [ff21testnum], are invalid. These tests may be invaild because (1) the
TestResultCode indicates that baseline data collection is ongoing, yet you reported a
prior test indicating that baseline data collection was completed; or (2) the
TestResultCode indicates that there were fewer than 168 fuel QA operating hours in the
quarter, yet your emissions data for that quarter indicates otherwise.
The [testtype] status for [key] could not be determined, because, according to the
fuel-flow-to-load test for MonitoringSystemID [ID] with TestNumber [ff21testnum],
baseline data was still being collected after the deadline.
The [testtype] status for [key] could not be determined, because a prior
fuel-flow-to-load test for MonitoringSystemID [ID] was missing for [missingff21].
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 2
Critical Error Level 1
Environmental Protection Agency
Page 30 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Name:
Check Code:
ADESTAT-12
Determine PEI Test Expiration Date
Related Former Checks:
Applicability:
Description:
Specifications:
Set PEIMissingOpDatalnfo = null.
if (PEIRequired == true AND CurrentPEIStatus is null)
Set PriorTestExpirationDate = Prior PEI Record. Te s t Ex p i ra t i o n D a t e.
for each quarter subsequent to the quarter of the Prior PEI Record.EndDdic and prior to the quarter of the CurrentOperatingDate
Set OSO Reporter to false.
Locate a LocationReportingFrequency record for the test location where ReportingFrequencyCode = "OS", the
BeginQuarter is on or before the quarter being checked, and the EndQuarter is null or is on or after the quarter being
checked.
If found,
Set OSO Reporter to true.
if (OSO Reporter == false or the quarter to check is the 3rd quarter)
if (FF2LPEIEligible == true and the quarter to check is between the FF2LPEIBeginYearQuarter and the
FF2LPEIEndYearQuarter (inclusive))
else if (OSO Reporter == true and the quarter to check is the 2nd quarter)
if (FF2 LPEI Eligible == true and the quarter to check is between the FF2LPEIBeginYearQuarter and the
FF2LPEIEndYearQuarter (inclusive))
Add 3 quarters to the PriorTestExpirationDate.
if (CurrentOperatingDate > PriorTestExpirationDate)
if (PEIMissingOpDatalnfo is not null)
Set CurrentPEIStatus = 'Missing Op Data"
else if (FF2LPEIEligible == false)
Set CurrentPEIStatus = "OOC-PEI Test Expired-Fuel Flow To Load Test Ignored"
else
Set CurrentPEIStatus = "OOC-PEI Test Expired"
Return result CurrentPEIStatus.
Add 1 quarter to the PriorTestExpirationDate.
else
Set CurrentPEIStatus = "IC-Extension"
Environmental Protection Agency
Page 31 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
Missing Op Data
OOC-PEI Test
Expired
OOC-PEI Test
Expired-Fuel
Flow To Load
Test Ignored
Usage:
1
Response
The [testtype] status for [key] could not be determined, because the Op Supp Data
record for OPHOURS, OSHOURS, or OPDAYS is missing for
[MISSINGOPDATAINFO] (and possibly other previous reporting periods). If you
have submitted emissions data for prior quarters, you should be able to retrieve these
records by logging on to the EPA host.
The prior [testtype] for [key] with TestNumber [testnum] has expired.
The prior [testtype] for [key] with TestNumber [testnum] has expired. A prior
fuel-flow-to-load test for MonitoringSystemID [ID] was ignored.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Process/Category: Emissions Data Evaluation Report Fuel Flowmeter QA Status Evaluation
Environmental Protection Agency
Page 32 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: ADESTAT-13
Check Name: Determine System Appendix D Status
Related Former Checks:
Applicability:
Description:
Specifications:
if (CurrentAppendixDStatus == "OOC-Multiple Reasons" OR (CurrentAppendixDStatus starts with "OOC" and CurrentAccuracyStatus
starts with "OOC" and CurrentAppendixDStatus <> CurrentAccuracyStatus))
Set CurrentAppendixDStatus = "OOC-Multiple Reasons"
else if (CurrentAppendixDStatus starts with "OOC")
-do nothing
else if (CurrentAccuracyStatus starts with "OOC")
Set CurrentAppendixDStatus = CurrentAccuracyStatus.
else if ((CurrentAppendixDStatus is not null and does not start with "IC" or "Undetermined" and CurrentAppendixDStatus does not end
with "Not Yet Evaluated") and (CurrentAccuracyStatus does not start with "IC" or "Undetermined" and CurrentAccuracyStatus does not
end with "Not Yet Evaluated") and CurrentAppendixDStatus <> CurrentAccuracyStatus)
Set CurrentAppendixDStatus = "Invalid Data".
else if (CurrentAppendixDStatus does not start with "IC" or "Undetermined" and CurrentAppendixDStatus does not end with "Not Yet
Evaluated" AND CurrentAppendixDStatus is not null)
-- do nothing
else if (CurrentAccuracyStatus does not start with "IC" or "Undetermined" and CurrentAccuracyStatus does not end with "Not Yet
Evaluated")
Set CurrentAppendixDStatus = CurrentAccuracyStatus.
else if (CurrentAppendixDStatus ends with "Not Yet Evaluated" or CurrentAccuracyStatus ends with "Not Yet Evaluated")
Set CurrentAppendixDStatus = "Test Not Yet Evaluated"
else if (CurrentAppendixDStatus starts with "Undetermined" or CurrentAccuracyStatus starts with "Undetermined")
Set CurrentAppendixDStatus = "Undetermined"
else if (CurrentAppendixDStatus == "IC-Extension" or CurrentAccuracyStatus == "IC-Extension")
Set CurrentAppendixDStatus = "IC-Extension"
else
Set CurrentAppendixDStatus = "IC"
if (PEIRequired == true)
if (CurrentAppendixDStatus == "OOC-Multiple Reasons" OR (CurrentAppendixDStatus starts with "OOC" and
CurrentPEIStatus starts with "OOC" and CurrentAppendixDStatus <> CurrentPEIStatus))
Environmental Protection Agency
Page 33 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Set CurrentAppendixDStatus = "OOC-Multiple Reasons"
else if (CurrentAppendixDStatus starts with "OOC")
-- do nothing
else if (CurrentPEIStatus starts with "OOC")
Set CurrentAppendixDStatus = CurrentPEIStatus.
else if ((CurrentAppendixDStatus is not null and does not start with "IC" or "Undetermined" and CurrentAppendixDStatus does
not end with "Not Yet Evaluated") and (CurrentPEIStatus does not start with "IC" or "Undetermined" and CurrentPEIStatus
does not end with "Not Yet Evaluated") and CurrentAppendixDStatus <> CurrentPEIStatus)
Set CurrentAppendixDStatus = "Invalid Data".
else if (CurrentAppendixDStatus does not start with "IC" or "Undetermined" and CurrentAppendixDStatus does not end with
"Not Yet Evaluated" AND CurrentAppendixDStatus is not null)
-- do nothing
else if (CurrentPEIStatus does not start with "IC" or "Undetermined" and CurrentPEIStatus does not end with "Not Yet
Evaluated")
Set CurrentAppendixDStatus = CurrentPEIStatus.
else if (CurrentAppendixDStatus ends with "Not Yet Evaluated" or CurrentPEIStatus ends with "Not Yet Evaluated")
Set CurrentAppendixDStatus = "Test Not Yet Evaluated"
else if (CurrentAppendixDStatus starts with "Undetermined" or CurrentPEIStatus starts with "Undetermined")
Set CurrentAppendixDStatus = "Undetermined"
else if (CurrentAppendixDStatus == "IC-Extension" or CurrentPEIStatus == "IC-Extension")
Set CurrentAppendixDStatus = "IC-Extension"
else
Set CurrentAppendixDStatus = "IC"
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report
Fuel Flowmeter QA Status Evaluation
Environmental Protection Agency
Page 34 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Category:
Daily Calibration Status
Environmental Protection Agency
Page 35 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: DCSTAT-1
Check Name: Locate Most Recent Prior Daily Calibration Test
Related Former Checks:
Applicability:
Description:
Specifications:
Set PriorDailyCalRecord = null.
Set InvalidDailyCalRecord = null.
Locate the most recent record in DailyCalTestRecordsByLocationForQAStatus for the location where:
a) ComponentID is equal to the ApplicableComponentID AND
b) ValidFlag is equal to "Y" AND
c) the SpanScaleCode is equal to the CurrentAnalyzerRangeUsed
if (DailyCalTestRecordsByLocationForQAStatus is found)
Set PriorDailyCalRecord = the found record in DailyCalTestRecordsByLocationForQAStatus.
Locate the most recent record in DailyCalTestRecordsByLocationForQAStatus for the location where:
a) the ComponentID is equal to the ApplicableComponentID AND
b) ValidFlag is equal to "N" AND
c) the SpanScaleCode is equal to the CurrentAnalyzerRangeUsed
if (DailyCalTestRecordsByLocation ForOAStatus is found AND EndDate/Hour/Min is greater than the
PriorDailyCalRecord.EndDi\\dY\ouxlMm)
Set InvalidDailyCalRecord = the found record in DailyCalTestRecordsByLocationForQAStatus.
else
Locate the most recent record in DailyCalTestRecordsByLocationForQAStatus for the location where:
a) the ComponentID is equal to the ApplicableComponentID AND
b) ValidFlag is equal to "N" AND
c) the SpanScaleCode is equal to the CurrentAnalyzerRangeUsed
if (DailyCalTestRecordsByLocationForQAStatus is found)
Set InvalidDailyCalRecord = the found record in DailyCalTestRecordsByLocationForQAStatus.
Results:
Result Response Severity
Environmental Protection Agency
Page 36 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Usage:
1
Process/Category:
Emissions Data Evaluation Report
C02 Daily Calibration Status Evaluation
2
Process/Category:
Emissions Data Evaluation Report
FLOW Daily Calibration Status Evaluation
3
Process/Category:
Emissions Data Evaluation Report
Hg Daily Calibration Status Evaluation
4
Process/Category:
Emissions Data Evaluation Report
NOX Daily Calibration Status Evaluation
5
Process/Category:
Emissions Data Evaluation Report
02 Dry Daily Calibration Status Evaluation
6
Process/Category:
Emissions Data Evaluation Report
02 Wet Daily Calibration Status Evaluation
7
Process/Category:
Emissions Data Evaluation Report
S02 Daily Calibration Status Evaluation
Environmental Protection Agency
Page 37 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: DCSTAT-2
Check Name: Locate Most Recent Prior Event
Related Former Checks:
Applicability:
Description:
Specifications:
Set Prior Daily CalE vent Record = null.
Set CurrentDailyCalStatus = null.
If (QaStatusSystemTypeCode is NOT equal to "HG")
Locate the most recent record in QACertificationEventRecords where:
a) the ComponentID is equal to the ApplicableComponentID AND
b) the QACertEventDate/Hour is on or prior to the CurrentDateHour AND
AND either
a) PriorDailyCalRecord is null AND the QACertEventDate/Hour is in the CurrentReportingPeriod OR
b) QACertEventDate/Hour is after the PriorDailyCalRecordEndDate/How
AND either
a) DualRangeStatus = false OR
b) HighRangeComponentID <> LowRangeComponentID OR
c) QACertEventCode <> 20, 25, 26, 30, or 172 and CurrentAnalyzerRangeUsed = "H" OR
d) QACertEventCode <> 35 or 171 and CurrentAnalyzerRangeUsed = "L"
if (QACertificationEventRecords is found)
Set PriorDailyCalEventRecord = the found record in QACertificationEventRecords
If (PriorDailyCalEventRecord is null)
if (PriorDailyCalRecord is null)
if (the number of clock hours between the First Day of Operation/First Hour of Operation and the CurrentDateHour is
less than 25)
Set CurrentDailyCalStatus = "IC-Undetermined".
else
Locate the latest record in HourlyOpData where the Date/Hour is ON OR PRIOR to the 24th clock hour following
the First Day of Operation/First Hour of Operation and OpTime is equal to zero.
if (HourlyOpData is found)
Locate the first record in HourlyOpData where the Date/Hour is after the Date/Hour in the
HourlyOpData record found above and ON OR PRIOR to the CurrentDateHour and the OpTime is
greater than zero.
if (not found OR the number of clock hours between HourlyOpData.DMc/Hour and the
CurrentDateHour is less than 8)
Set CurrentDailyCalStatus = "IC-Undetermined".
Environmental Protection Agency
Page 38 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
else
Set CurrentDailyCalStatus = "OOC-No Prior Test".
else
Set CurrentDailyCalStatus = "OOC-No Prior Test".
else
if (PriorDailyCalRecord .TestResultCode = null)
Set CurrentDailyCalStatus = "OOC-Test Has Critical Errors",
else if (PriorDailyCalRecord .TestResultCode = "FAILED")
Set CurrentDailyCalStatus = "OOC-Test Failed",
else if (PriorDailyCalRecord .TestResultCode = "ABORTED")
Set CurrentDailyCalStatus = "OOC-Test Aborted".
else
Set CurrentDailyCalStatus = "OOC-Event".
if (InvalidDailyCalRecord is not null and InvalidDailyCalRecord.EndDate/How is BEFORE the
PriorDailyCalEventRecord.QACertEventDate/Hour)
Set InvalidDailyCalRecord = null.
Results:
Result Response Severity
Usage:
1
Process/Category:
Emissions Data Evaluation Report
C02 Daily Calibration Status Evaluation
2
Process/Category:
Emissions Data Evaluation Report
FLOW Daily Calibration Status Evaluation
3
Process/Category:
Emissions Data Evaluation Report
Hg Daily Calibration Status Evaluation
4
Process/Category:
Emissions Data Evaluation Report
NOX Daily Calibration Status Evaluation
5
Process/Category:
Emissions Data Evaluation Report
02 Dry Daily Calibration Status Evaluation
6
Process/Category:
Emissions Data Evaluation Report
02 Wet Daily Calibration Status Evaluation
7
Process/Category:
Emissions Data Evaluation Report
S02 Daily Calibration Status Evaluation
Environmental Protection Agency
Page 39 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: DCSTAT-3
Check Name: Determine Test Expiration Date for Most Recent Prior Daily Calibration Test
Related Former Checks:
Applicability:
Description:
Specifications:
Set OnlineDailyCalRecord to null,
if (CurrentDailyCalStatus is null)
if (Prior DailyCalRecord. On 1 i ne Indicator ==1)
if (the number of clock hours between the PriorDailyCalRecordDate/How and the CurrentDateHour is less than 26)
Set CurrentDailyCalStatus = "IC".
else
Locate the latest record in HourlyOpData where OpTime is equal to zero and the number of clock hours between
the Date/Hour and the PriorDailyCalRecord.Date/How is less than or equal to 26.
if (HourlyOpData is found)
Locate the earliest record in HourlyOpData where the Date/Hour is after the Date/Hour in the
HourlyOpData record found above and OpTime is greater than zero.
if (the number of clock hours between the HourlyOpData.Date/Hour and the CurrentDateHour is greater
than or equal to 8)
Set CurrentDailyCalStatus = "OOC-Expired".
else
Set CurrentDailyCalStatus = "IC-Grace".
else
Set CurrentDailyCalStatus = "OOC-Expired".
else
Locate the most recent record in DailyCalTestRecordsByLocationForQAStatus for the location where:
a) ComponentID is equal to the ApplicableComponentID AND
b) ValidFlag is equal to "Y" AND
c) the Onlinelndicator = 1 AND
d) the SpanScaleCode is equal to the CurrentAnalyzerRangeUsed
if (DailyCalTestRecordsByLocationForQAStatus is found
Set OnlineDailyCalRecord = the found record in DailyCalTestRecordsByLocationForQAStatus.
if (InvalidDailyCalRecord is null)
Locate the record in DailyCalTestRecordsByLocationForQAStatus for the location where:
Environmental Protection Agency
Page 40 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
a) the ComponentID is equal to the ApplicableComponentID AND
b) ValidFlag is equal to "N" AND
c) the Onlinelndicator = 1 AND
d) the SpanScaleCode is equal to the CurrentAnalyzerRangeUsed
if (DailyCalTestRecordsByLocationForOAStatus is found AND the EndDate/Hour is after the
OnlineDailyCalRecord.EndDate/Rom AND the EndDate/Hour is equal to or prior to the
PriorDailyCalRecordDatefHouf)
set InvalidDailyCalRecord = the found record in DailyCalTestRecordsByLocationForQAStatus.
if (OnlineDailyCalRecord .TestResultCode = null)
Set CurrentDailyCalStatus = "OOC-Prior Online Test Has Critical Errors".
else if (OnlineDailyCalRecord .TestResultCode = "FAILED")
Set CurrentDailyCalStatus = "OOC-Prior Online Test Failed".
else if (OnlineDailyCalRecord.TestResultCode = "ABORTED")
Set CurrentDailyCalStatus = "OOC-Prior Online Test Aborted".
else if (the number of OPERATING hours between the OnlineDailyCalRecord.Date/Hour and the
CurrentDateHour is less than 26 AND the number of clock hours between the PriorDailyCalRecord.DatefRour
and the CurrentDateHour is less than 26)
Set CurrentDailyCalStatus = "IC".
else
if (the number of clock hours between the OnlineDailyCalRecord Date/Hour and the CurrentDateHour is
less than 26)
Set CurrentDailyCalStatus = "IC".
else
Locate the latest record in HourlyOpData where OpTime is equal to zero and the number of clock
hours between the Date/Hour and the OnlineDailyCalRecord.Date/Hour is less than or equal to
26.
if (HourlyOpData is found)
Locate the earliest record in HourlyOpData where the Date/Hour is after the Date/Hour
in the HourlyOpData record found above and OpTime is greater than zero.
if (the number of clock hours between the HourlyOpData.Date/Rour and the
CurrentDateHour is greater than or equal to 8)
Set CurrentDailyCalStatus = "OOC-Expired".
else
Set CurrentDailyCalStatus = "IC-Grace".
else
Environmental Protection Agency
Page 41 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Set CurrentDailyCalStatus = "OOC-Expired".
else
if (Rpt Period Op Hour Accumulator Array for the location is less than 26)
Set CurrentDailyCalStatus = "IC-Undetermined".
else
Set CurrentDailyCalStatus = "OOC-Expired".
Results:
Result Response Severity
Usage:
1
Process/Category:
Emissions Data Evaluation Report
C02 Daily Calibration Status Evaluation
2
Process/Category:
Emissions Data Evaluation Report
FLOW Daily Calibration Status Evaluation
3
Process/Category:
Emissions Data Evaluation Report
Hg Daily Calibration Status Evaluation
4
Process/Category:
Emissions Data Evaluation Report
NOX Daily Calibration Status Evaluation
5
Process/Category:
Emissions Data Evaluation Report
02 Dry Daily Calibration Status Evaluation
6
Process/Category:
Emissions Data Evaluation Report
02 Wet Daily Calibration Status Evaluation
7
Process/Category:
Emissions Data Evaluation Report
S02 Daily Calibration Status Evaluation
Environmental Protection Agency
Page 42 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: DCSTAT-4
Check Name: Determine Final Daily Calibration Status
Related Former Checks:
Applicability:
Description:
Specifications:
Set AlternateDailyCalRecord = null.
if (CurrentDailyCalStatus begins with "OOC")
if (InvalidDailyCalRecord is not null)
Set CurrentDailyCalStatus = CurrentDailyCalStatus &
Return result CurrentDailyCalStatus.
else if (DualRangeStatus = true and CurrentDailyCalStatus begins with "IC")
if (CurrentAnalyzerRangeUsed = "H")
Set AlternateAnalyzerRange = "L".
Set AlternateComponentID = LowRangeComponentlD.
else
Set AlternateAnalyzerRange = "H".
Set AlternateComponentID = HighRangeComponentlD.
Locate the most recent record in DailyCalTestRecordsByLocationForQAStatus for the location where:
a) ComponentID is equal to the AlternateComponentID AND
b) ValidFlag = "Y" AND
c) SpanScaleCode is equal to the AlternateAnalyzerRange
if (DailyCalTestRecordsByLocationForQAStatus is found)
Set AlternateDailyCalRecord = the found record in DailyCalTestRecordsByLocationForQAStatus.
if {AlternateDailyCalRecord is not null)
if (A Item ateDailyCalRecord. Tc s t R c s u 11C o dc = null)
Set CurrentDailyCalStatus = "OOC-Alternate Range Test Has Critical Errors",
else if (AlternateDailyCalRecordTestResultCode= "FAILED")
Set CurrentDailyCalStatus = "OOC-Alternate Range Test Failed",
else if (AlternateDailyCalRecord TesiResultCode = "ABORTED")
Set CurrentDailyCalStatus = "OOC-Alternate Range Test Aborted".
else
Locate the latest record in DailyCalTestRecordsByLocationForQAStatus for the location where:
Environmental Protection Agency
Page 43 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
a) ComponentID is equal to the AlternateComponentID AND
b) the SpanScaleCode is equal to the AlternateAnalyzerRange
c) the TestResultCode is equal to "FAILED" or "ABORTED"
if (DailyCalTestRecordsByLocationForQAStatus is found AND (either the PriorDailyCalRecord is null or
EndDate/Hour/Minute is after the PriorDailyCalRecord En&DMdHouxIMimtic))
Set CurrentDailyCalStatus = "OOC-No Passing Test After Alternate Range Failed Test".
(Report this status in the Evaluation Report under the PriorDailyCalRecord.7cs{Di\{c/Hour.)
Else
Locate the latest record in DailyCalTestRecordsByLocationForQAStatus for the location where:
a) ComponentID is equal to the ApplicableComponentID AND
b) the SpanScaleCode is equal to the CurrentAnalyzerRangeUsed
c) the TestResultCode is equal to "FAILED" or "ABORTED"
if (DailyCalTestRecordsByLocationForOAStatus is found AND EndDate/Hour/Minute is after the
A IternateDailyCalRecord. E ndDatc/Hour/IVI i nutc)
Set CurrentDailyCalStatus = "OOC-No Passing Alternate Range Test After Failed Test".
(Report this status in the Evaluation Report under the PriorDailyCalRecord. TcstDatc/Hour.)
if (CurrentDailyCalStatus begins with "OOC")
if (InvalidDailyCalRecord is not null)
Set CurrentDailyCalStatus = CurrentDailyCalStatus &
Locate the most recent record in DailyCalTestRecordsByLocationForQAStatus for the location where:
a) ComponentID is equal to the AlternateComponentID AND
b) ValidFlag is equal to "N" AND
c) the SpanScaleCode is equal to the AlternateAnalyzerRange
if (DailyCalTestRecordsByLocationForQAStatus is found AND the EndDate/Hour is after the
AltemateDailyCalRecord.EndDMc/Hour)
Set InvalidDailyCalRecord = the found record in DailyCalTestRecordsByLocationForQAStatus.
Set CurrentDailyCalStatus = CurrentDailyCalStatus &
Return result CurrentDailyCalStatus.
elseif (CurrentDailyCalStatus does not begin with "IC")
Return result CurrentDailyCalStatus.
Environmental Protection Agency
Page 44 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
OOC-Alternate
Range Test
Aborted
OOC-Alternate
Range Test
Aborted*
OOC-Alternate
Range Test
Failed
OOC-Alternate
Range Test
Failed*
OOC-Alternate
Range Test Has
Critical Errors
OOC-Alternate
Range Test Has
Critical Errors*
OOC-Event
OOC-Event*
OOC-Expired
OOC-Expired*
OOC-No Passing
Alternate Range
Test After Failed
Test
OOC-No Passing
Alternate Range
Test After Failed
Test*
OOC-No Passing
Test After
Alternate Range
Failed Test
OOC-No Passing
Test After
Alternate Range
Failed Test*
OOC-No Prior
Test
OOC-No Prior
Test*
OOC-No
Probationary
Calibration Test
Response
The prior daily calibration test for the alternate range [altscale] cf [compkey], which
was completed on [altdate], was aborted.
The prior daily calibration test for the alternate range [altscale] cf [compkey], which
was completed on [altdate], was aborted. An invalid daily calibration test completed on
[invdate] was ignored.
The prior daily calibration test for the alternate range [altscale] cf [compkey], which
was completed on [altdate], failed.
The prior daily calibration test for the alternate range [altscale] cf [compkey], which
was completed on [altdate], failed. An invalid daily calibration test completed on
[invdate] was ignored.
The prior daily calibration test for the alternate range [altscale] cf [compkey], which
was completed on [altdate], has critical errors.
The prior daily calibration test for the alternate range [altscale] cf [compkey], which
was completed on [altdate], has critical errors. An invalid daily calibration test
completed on [invdate] was ignored.
You reported a QA Certification Event record for QACertEventCode [code]
QACertEventDate [eventdate] for [compkey], but you did not perform a subsequent
daily calibration test.
You reported a QA Certification Event record for QACertEventCode [code]
QACertEventDate [eventdate] for [compkey], but you did not perform a subsequent
daily calibration test. An invalid daily calibration test completed on [invdate] was
ignored.
The prior daily calibration test for [compkey] completed on [date] has expired.
The prior daily calibration test for [compkey] completed on [date] has expired. An
invalid daily calibration test completed on [invdate] was ignored.
The prior daily calibration test for [compkey] was completed on [date], however a
subsequent passing test on [altscale] has not been completed. When a daily calibration
test is failed for a dual-range analyzer, you must complete a passing daily calibration
test on both ranges before the monitor is considered to be in-control. An invalid daily
calibration test completed on [invdate] was ignored.
The prior daily calibration test for [compkey] was completed on [date], however a
subsequent passing test on [altscale] has not been completed. When a daily calibration
test is failed for a dual-range analyzer, you must complete a passing daily calibration
test on both ranges before the monitor is considered to be in-control. An invalid daily
calibration test completed on [invdate] was ignored.
The prior daily calibration test for [compkey] was completed on [date], which is prior to
a failed or aborted test for the alternate range [altscale]. When a daily calibration test is
failed for a dual-range analyzer, you must complete a passing daily calibration test on
both ranges before the monitor is considered to be in-control.
The prior daily calibration test for [compkey] was completed on [date], which is prior to
a failed or aborted test for the alternate range [altscale]. When a daily calibration test is
failed for a dual-range analyzer, you must complete a passing daily calibration test on
both ranges before the monitor is considered to be in-control. An invalid daily
calibration test completed on [invdate] was ignored.
You did not report a prior daily calibration test for [compkey] during the reporting
period. Any daily calibration test that may have been completed in a prior reporting
period has expired.
You did not report a prior daily calibration test for [compkey] during the reporting
period. Any daily calibration test that may have been completed in a prior reporting
period has expired. An invalid daily calibration test completed on [invdate] was
ignored.
This check result is obsolete.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
No Errors
Environmental Protection Agency
Page 45 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
This check result is obsolete.
No Errors
The prior online daily calibration test for [compkey] completed on [ondate] was
aborted.
The prior online daily calibration test for [compkey] completed on [ondate] was
aborted. An invalid daily calibration test completed on [invdate] was ignored.
Critical Error Level 1
Critical Error Level 1
OOC-No
Probationary
Calibration Test*
OOC-Prior
Online Test
Aborted
OOC-Prior
Online Test
Aborted*
OOC-Prior
Online Test
Expired
OOC-Prior
Online Test
Expired*
OOC-Prior
Online Test
Failed
OOC-Prior
Online Test
Failed*
OOC-Prior
Online Test Has errors.
Critical Errors
OOC-Prior The prior online daily calibration test for [compkey] completed on [ondate] has critical Critical Error Level 1
Online Test Has errors. An invalid daily calibration test completed on [invdate] was ignored.
Critical Errors*
The prior daily calibration test for [compkey] completed on [date] was aborted.
The prior online daily calibration test for [compkey] completed on [ondate] has expired. Critical Error Level 1
The prior online daily calibration test for [compkey] completed on [ondate] has expired. Critical Error Level 1
An invalid daily calibration test completed on [invdate] was ignored.
The prior online daily calibration test for [compkey] completed on [ondate] failed.
Critical Error Level 1
The prior online daily calibration test for [compkey] completed on [ondate] failed. An Critical Error Level 1
invalid daily calibration test completed on [invdate] was ignored.
The prior online daily calibration test for [compkey] completed on [ondate] has critical Critical Error Level 1
OOC-Test
Aborted
OOC-Test
Aborted*
The prior daily calibration test for [compkey] completed on [date] was aborted. An
invalid daily calibration test completed on [invdate] was ignored.
OOC-Test Failed The prior daily calibration test for [compkey] completed on [date] failed.
OOC-Test
Failed*
OOC-Test Has
Critical Errors
OOC-Test Has
Critical Errors*
The prior daily calibration test for [compkey] completed on [date] failed. An invalid
daily calibration test completed on [invdate] was ignored.
The prior daily calibration test for [compkey] completed on [date] has critical errors.
The prior daily calibration test for [compkey] completed on [date] has critical errors.
An invalid daily calibration test completed on [invdate] was ignored.
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1
Process/Category:
Emissions Data Evaluation Report
C02 Daily Calibration Status Evaluation
2
Process/Category:
Emissions Data Evaluation Report
FLOW Daily Calibration Status Evaluation
3
Process/Category:
Emissions Data Evaluation Report
Hg Daily Calibration Status Evaluation
4
Process/Category:
Emissions Data Evaluation Report
NOX Daily Calibration Status Evaluation
5
Process/Category:
Emissions Data Evaluation Report
02 Dry Daily Calibration Status Evaluation
6
Process/Category:
Emissions Data Evaluation Report
02 Wet Daily Calibration Status Evaluation
7
Process/Category:
Emissions Data Evaluation Report
S02 Daily Calibration Status Evaluation
Environmental Protection Agency
Page 46 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Category:
Daily Calibration Test
Environmental Protection Agency
Page 47 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
DAYCAL-1
Check Name:
Daily Calibration Test Component Type Check
Related Former Checks:
Applicability:
Description:
Specifications:
For the daily calibration test:
Set Daily Cal Calc Result to null.
Set Daily Cal Fail Date and Daily Cal Fail Hour to null.
If the ComponentID is null,
set Daily Cal Component Type Valid to false,
return result A.
Otherwise,
If the ComponentTypeCode of the associated component is equal to "S02", "NOX", "C02", "02", or "FLOW",
set Daily Cal Component Type Valid to true.
Else if the ComponentTypeCode of the associated component is equal to "HG",
If (OnlineOfflinelndicator is equal to 1)
set Daily Cal Component Type Valid to true.
Else
set Daily Cal Component Type Valid to false,
return result C.
Otherwise,
set Daily Cal Component Type Valid to false,
return result B.
If component is invalid, do not perform injection-based checks. Set the calculated values to null.
Results:
Result
A
B
Response
You did not provide [fieldname], which is required for [key].
The ComponentTypeCode in the monitoring plan is [comptype]. This type of
component does not require a calibration test. Only component types 'S02', 'NOX',
'C02', '02', "HG", or 'FLOW' may have a daily calibration test.
For Hg CEMS, all calibrations must be done while unit is online.
Severity
Fatal
Critical Error Level 1
C
Critical Error Level 1
Environmental Protection Agency
Page 48 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
Usage:
1 Process/Category: Emissions Data Evaluation Report Daily Calibration Test
Environmental Protection Agency
Page 49 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
DAYCAL-2
Check Name:
Aborted and Incomplete Daily Calibration Test Check
Related Former Checks:
Applicability:
Description:
Specifications:
For the daily calibration test:
Set Evaluate Upscale Injection AND Evaluate Zero Injection to false.
If Daily Cal Component Type Valid is equal to true,
If the TestResultCode is equal to "ABORTED",
set Daily Cal Calc Result to "ABORTED", and return result A.
If the TestResultCode is equal to "INC",
set Daily Cal Calc Result to "INC".
If ZeroInjectionDate, ZeroInjectionHour, and ZeroMeasuredValue are not null,
set Evaluate Zero Injection to true.
If UpscalelnjectionDate, UpscalelnjectionHour, and UpscaleMeasuredValue are not null,
set Evaluate Upscale Injection to true.
Otherwise,
set Evaluate Upscale Injection AND Evaluate Zero Injection to true.
Results:
Result
A
Response
The TestResultCode indicates that the [type] test for [key] was aborted. If the test was
aborted for a reason not related to monitor performance, you should not report the test.
Severity
Informational Message
Usage:
1 Process/Category: Emissions Data Evaluation Report Daily Calibration Test
Environmental Protection Agency
Page 50 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: DAYCAL-3
Check Name: Online Offline Indicator Valid
Related Former Checks:
Applicability:
Description:
Specifications:
For a daily calibration test:
Set Daily Cal Calc Online Ind to null.
If ZeroOpTime is equal to 0 OR UpscaleOpTime is equal to 0
set Daily Cal Calc Online Ind to 0
else if ZeroOpTime is equal to 1 AND UpscaleOpTime is equal to 1
set Daily Cal Calc Online Ind to 1
else
set Daily Cal Calc Online Ind to the OnlineOfflinelndicator.
If (OnlineOfflinelndicator is null)
return result A.
else if (ComponentTypeCode is equal to "HG")
If (OnlineOfflinelndicator is equal to 1) // Earlier component type error will occur if indicator is not 1
If (Daily Cal Calc Online Ind is equal to 0)
return result E.
If (Daily Cal Calc Online Ind is equal to 0)
If (OnlineOfflinelndicator is equal to 1)
return result B.
Locate the latest OOC Test Record for the location where the ComponentID and SpanScaleCode is equal
to the ComponentID and SpanScaleCode in the current test and the EndDate/Hour is prior to the
Date/Hour of the current test.
If not found,
Set Ignored Daily Calibration Tests to true.
If (Daily Cal Calc Result <> "INVALID")
set Daily Cal Calc Result to "IGNORED"
Otherwise,
Locate an OA Certification Event Record for the location where the ComponentID is equal to the
ComponentID in the current test AND OOCRequired == "Y" AND the EventDate/Hour is after
the EndDate/Hour of the retrieved OOC test AND the EventDate/Hour is on or before the
EndDate/Hour of the current test AND EITHER
a) SpanScaleCode in the current test is null OR
b) SpanScaleCode in the current test == "H" and QACertEventCode <> 20, 25, 26, 30, or 172 OR
c) SpanScaleCode in the current test == "L" and QACertEventCode <> 35 or 171
Environmental Protection Agency
Page 51 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
If found,
return result D.
Results:
Result
A
B
C
D
Response
You did not provide [fieldname], which is required for [key].
The OnlineOfflinelndicator in the daily calibration test indicates that the test was
performed on-line, but OperatingTime in the Hourly Operating Data record is 0.
This check result is obsolete.
The test was peformed while the unit was not operating, but this is not valid, because
you reported an QA Certification Event record indicating that you needed to perform an
online-offline calibration demonstration allowing you to conduct off -line daily
calibration tests. However, you have not reported an online-offline calibration
demonstration subsequent to the EventDate and EventHour in the QA Certification
Event record.
For Hg CEMS, all calibrations must be done while unit is online.
Severity
Critical Error Level 1
Critical Error Level 1
No Errors
Critical Error Level 2
Critical Error Level 1
Usage:
1
Process/Category: Emissions Data Evaluation Report Daily Calibration Test
Environmental Protection Agency
Page 52 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
DAYCAL-4
Check Name:
Test Span Scale Valid
Related Former Checks:
Applicability:
Description:
Specifications:
For a daily calibration test with a valid component:
Set Daily Cal Span Scale Valid to true.
If the ComponentTypeCode of the associated component is not equal to "FLOW" and not equal to "HG",
If the SpanScaleCode is null,
set Daily Cal Span Scale Valid to false, and return result A.
If the SpanScaleCode is not equal to "H" or "L",
set Daily Cal Span Scale Valid to false, and return result B.
If the EM Test Date Valid AND EM Test Hour Valid are true,
If the SpanScaleCode is equal to "H"
Locate an Analyzer Range record for the component where the AnalyzerRangeCode is equal to "L", the
BeginDate and BeginHour is on or before the Date and Hour in the current test, and the EndDate is null or
the EndDate and EndHour is on or after the Date and Hour of the current test.
If the SpanScaleCode is equal to "L"
Locate an Analyzer Range record for the component where the AnalyzerRangeCode is equal to "H", the
BeginDate and BeginHour is on or before the Date and Hour of the current test, and the EndDate is null or
the EndDate and EndHour is on or after the Date and Hour of the current test.
Else, if the ComponentTypeCode of the associated component is equal to "HG",
If the SpanScaleCode is null,
set Daily Cal Span Scale Valid to false, and return result A.
Else if the SpanScaleCode is not equal to "H",
set Daily Cal Span Scale Valid to false, and return result B.
Otherwise,
If the SpanScaleCode is not null,
set Daily Cal Span Scale Valid to false, and return result D.
If found,
set Daily Cal Span Scale Valid to false, and return result C.
If found,
set Daily Cal Span Scale Valid to false, and return result C.
Environmental Protection Agency
Page 53 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
A
B
C
D
Usage:
1
Response Severity
You did not provide [fieldname], which is required for [key]. Critical Error Level 1
You reported the value [value], which is not in the list of valid values, in the field Critical Error Level 1
[fieldname] for [key].
The active analyzer range for the component is inconsistent with the span scale [value] Critical Error Level 1
reported for the [type] test for [key].
You reported a SpanScaleCode in the [type] test for [key], but this is not appropriate for Critical Error Level 1
flow component.
Process/Category: Emissions Data Evaluation Report Daily Calibration Test
Environmental Protection Agency
Page 54 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: DAYCAL-5
Check Name: Determine Span Value
Related Former Checks:
Applicability:
Description:
Specifications:
For a daily calibration test:
Set Daily Cal Span Value to null.
If EM Test Date Valid, EM Test Hour Valid, and Daily Cal Span Scale Value are all true,
Locate the System Component records for the associated component with the earliest Begin Date.
If found,
If the BeginDate in the retrieved record is not null, the BeginHour in the retrieved record is between 0 and 23, and
the BeginDate and BeginHour is later than the Date and Hour of the test.
Locate a Span Record for the location where the ComponentTypeCode equal to the ComponentTypeCode
of the associated component, the SpanScaleCode is equal to the SpanScaleCode in the test, the Span Value
is greater than 0, the BeginDate and BeginHour is on or before the BeginDate and BeginHour of the
retrieved record, and the EndDate is null or the EndDate and EndHour is after the BeginDate and
BeginHour of the retrieved record.
Otherwise,
Locate a Span Record for the location where the ComponentTypeCode equal to the ComponentTypeCode
of the associated component, the SpanScaleCode is equal to the SpanScaleCode in the test, the Span Value
is greater than 0, the BeginDate and BeginHour is on or before the Date and Hour of the test, and the
EndDate is null or the EndDate and EndHour is after the Date and Hour of the test.
If not found,
return result A.
If more than one record is found,
return result B.
If one record is found,
set Daily Cal Span Value to the SpanValue in the retrieved span record.
else
return result C.
Environmental Protection Agency
Page 55 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result Response Severity
A You have not reported a valid monitoring plan span record that was active during the Critical Error Level 1
test for [key].
B You reported more than one monitoring plan span record that was active during the test Critical Error Level 1
for [key].
C The component reported for [key] is not part of any monitoring system. Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Daily Calibration Test
Environmental Protection Agency
Page 56 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
DAYCAL-6
Check Name:
Daily Calibration Test Upscale Gas Level Code Valid
Related Former Checks:
Applicability:
Description:
Specifications:
For the daily calibration test with an upscale injection:
If the UpscaleGasCode is null,
set Daily Cal Upscale Gas Level Valid to false, and return result A.
If the UpscaleGasCode is not equal to "MID" or "HIGH",
set Daily Cal Upscale Gas Level Valid to false, and return result B.
If the ComponentTypeCode of the associated component is equal to "FLOW", and the UpscaleGasLevelCode is equal to "MID",
set Daily Cal Upscale Gas Level Valid to false, and return result C.
Otherwise,
set Daily Cal Upscale Gas Level Valid to true.
Results:
Result
A
B
Response
You did not provide [fieldname], which is required for [key].
You reported the value [value], which is not in the list of valid values, in the field
[fieldname] for [key].
You have reported a value of "MID" as the UpscaleGasCode. This value is not
appropriate for flow components.
Severity
Critical Error Level 1
Critical Error Level 1
C
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Daily Calibration Test
Environmental Protection Agency
Page 57 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: DAYCAL-7
Check Name: Reference Values Consistent with Calibration Gas Levels
Related Former Checks:
Applicability:
Description:
Specifications:
For the daily calibration test with an upscale and zero injection:
If ZeroReferenceValue greater than or equal to 0, UpscaleReferenceValue greater than 0, AND ZeroReferenceValue is greater than
or equal to UpscaleReferenceValue,
set Daily Cal Calc Result to "INVALID", and return result A.
Results:
Result Response Severity
A The reference value is not consistent with the reported calibration gas levels in the daily Critical Error Level 1
calibration test for [key]. The reference values of zero-level gas injection or reference
signals must be less than that of the upscale gas injection.
Usage:
1 Process/Category: Emissions Data Evaluation Report Daily Calibration Test
Environmental Protection Agency
Page 58 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
DAYCAL-8
Check Name:
Zero Measured Value Valid
Related Former Checks:
Applicability:
Description:
Specifications:
For the daily calibration test with a zero injection:
If ZeroMeasuredValue is null,
return result A.
Results:
Result
A
Response
You did not provide [fieldname], which is required for [key].
Severity
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Daily Calibration Test
Environmental Protection Agency
Page 59 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: DAYCAL-9
Check Name: Zero Reference Value Valid
Related Former Checks:
Applicability:
Description:
Specifications:
For the daily calibration test with a zero injection:
If ZeroReferenceValue is null,
return result A.
If ZeroReference Value is less than 0,
return result B.
Results:
Severity
Critical Error Level 1
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Daily Calibration Test
Result Response
A You did not provide [fieldname], which is required for [key].
B The value [value] in the field [fieldname] for [key] is not within the range of valid
values. This value must be greater than or equal to zero.
Environmental Protection Agency
Page 60 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: DAYCAL-10
Check Name: Zero Calibration Error Valid
Related Former Checks:
Applicability:
Description:
Specifications:
For the daily calibration test with a zero injection:
If the ZeroCalibrationError is null,
return result A.
If the ZeroCalibrationError is less than 0,
return result B.
Results:
Severity
Critical Error Level 1
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Daily Calibration Test
Result Response
A You did not provide [fieldname], which is required for [key].
B The value [value] in the field [fieldname] for [key] is not within the range of valid
values. This value must be greater than or equal to zero.
Environmental Protection Agency
Page 61 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
DAYCAL-11
Check Name:
Zero APS Indicator Valid
Related Former Checks:
Applicability:
Description:
Specifications:
For the daily calibration test with a zero injection:
If ZeroAPSIndicator is null,
return result A.
Results:
Result
A
Response
You did not provide [fieldname], which is required for [key].
Severity
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Daily Calibration Test
Environmental Protection Agency
Page 62 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
DAYCAL-12
Check Name:
Upscale Measured Value Valid
Related Former Checks:
Applicability:
Description:
Specifications:
For the daily calibration test with an upscale injection:
If UpscaleMeasuredValue is null,
return result A.
Results:
Result
A
Response
You did not provide [fieldname], which is required for [key].
Severity
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Daily Calibration Test
Environmental Protection Agency
Page 63 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: DAYCAL-13
Check Name: Upscale Reference Value Valid
Related Former Checks:
Applicability:
Description:
Specifications:
For the daily calibration test with an upscale injection:
If UpscaleReferenceValue is null,
return result A.
If UpscaleReferenceValue is less than or equal to 0,
return result B.
Results:
Severity
Critical Error Level 1
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Daily Calibration Test
Result Response
A You did not provide [fieldname], which is required for [key].
B The value [value] in the field [fieldname] for [key] is not within the range of valid
values. This value must be greater than zero.
Environmental Protection Agency
Page 64 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: DAYCAL-14
Check Name: Upscale Calibration Error Valid
Related Former Checks:
Applicability:
Description:
Specifications:
For the daily calibration test with an upscale injection:
If the UpscaleCalibrationError is null,
return result A.
If the UpscaleCalibrationError is less than 0,
return result B.
Results:
Severity
Critical Error Level 1
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Daily Calibration Test
Result Response
A You did not provide [fieldname], which is required for [key].
B The value [value] in the field [fieldname] for [key] is not within the range of valid
values. This value must be greater than or equal to zero.
Environmental Protection Agency
Page 65 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
DAYCAL-15
Check Name:
Upscale APS Indicator Valid
Related Former Checks:
Applicability:
Description:
Specifications:
For the daily calibration test with an upscale injection:
If Upscale APSIndicator is null,
return result A.
Results:
Result
A
Response
You did not provide [fieldname], which is required for [key].
Severity
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Daily Calibration Test
Environmental Protection Agency
Page 66 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
DAYCAL-16
Check Name:
Upscale Injection Time Valid
Related Former Checks:
Applicability:
Description:
Specifications:
For the daily calibration test with an upscale injection:
If the UpscalelnjectionHour is not between 0 and 23, or the UpscalelnjectionMinute is null and Legacy Data Evaluation == false,
or the UpscalelnjectionMinute is not between 0 and 59,
set Daily Cal Upscale Injection Time Valid to false, and return result A.
Otherwise,
set
Daily Cal Upscale Injection Time Valid to true.
Results:
Result
A
Response
The [type] date, hour, and/or minute for [key] is invalid.
Severity
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Daily Calibration Test
Environmental Protection Agency
Page 67 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: DAYCAL-17
Check Name: Zero Injection Time Valid
Related Former Checks:
Applicability:
Description:
Specifications:
For the daily calibration test with a zero injection:
If the ZeroInjectionHour is not between 0 and 23, or the ZeroInjectionMinute is null and Legacy Data Evaluation == false, or the
ZeroInjectionMinute is not between 0 and 59,
set Daily Cal Injection Times Valid to false, and return result A.
else if Legacy Data Evaluation == false, the UpscalelnjectionDate is not null, the UpscalelnjectionHour is between 0 and 23, the
UpscalelnjectionMinute is between 0 and 59, and the UpscalelnjectionDate, UpscalelnjectionHour, and UpscalelnjectionMinute
are equal to the ZeroIniectionDate, ZeroIniectionHour, and ZeroIniectionMinute, and the associated ComponentTypeCode is not
equal to "FLOW"
set Daily Cal Injection Times Valid to false, and return result B.
Otherwise,
set Daily Cal Injection Times Valid to Daily Cal Upscale Injection Time Valid.
Locate another Daily Calibration Test Record for the location where the ComponentID and SpanScale are equal to the
ComponentID and SpanScale in the current record, TestResultCode is not equal to "INC", and the EndDate/Hour/Minute is
between the UpscalelnjectionDate/Hour/Minute and ZeroInjectionDate/Hour/Minute of the current test.
If found,
return result C.
else
If the absolute value of the difference between the ZeroInjectionDate/Hour and the UpscalelnjectionDate/Hour in
the current test is greater than 1,
return result D.
Results:
Result
A
B
C
D
Response
The [type] date, hour, and/or minute for [key] is invalid.
You reported that the zero injection and upscale injection for [key] were performed at
the same time. This is invalid.
This [testtype] was conducted at the same time as another [testtype] for the same
component and range.
The zero and upscale injections for [key] were not performed in the same or adjacent
clock hours.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 2
Usage:
1
Process/Category: Emissions Data Evaluation Report Daily Calibration Test
Environmental Protection Agency
Page 68 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: DAYCAL-18
Check Name: Zero Reference Value Consistent with Span
Related Former Checks:
Applicability:
Description:
Validation Tables:
Test Tolerances (Cross Check Table)
Specifications:
For the daily calibration test with a Daily Cal Span Value that is not null and a ZeroReferenceValue greater than or equal to 0:
If the ComponentTypeCode of the associated component is not equal to "HG",
Calculate Zero Reference Percent of Span = ZeroReferenceValue / Daily Cal Span Value * 100, and round to result to
one decimal place.
If Zero Reference Percent of Span is greater than 20.0,
Locate the Test Tolerance cross-check record where the TestTypeCode is equal to "7DAY" and the
FieldDescription is equal to "GasPercentOfSpan".
If Zero Reference Percent of Span is greater than 20.0 + Tolerance in the cross-check record,
return result A.
Otherwise,
return result B.
Results:
Result
A
B
Response
The tag value of at least one Zero level reference signal or calibration gas for [key] is
[percent]%, which does not meet the performance specifications of 40 CFR Part 75.
The concentration of the zero reference signal or calibration gas must be less than or
equal to 20.0% of the span value. The test is invalid.
The tag value of at least one zero level reference signal or calibration gas for [key] is
[percent]%, which does not meet the performance specifications of 40 CFR Part 75.
The concentration of the zero reference signal or calibration gas must be less than or
equal to 20.0% of the span value.
Severity
Critical Error Level 2
Non-Critical Error
Usage:
1
Process/Category: Emissions Data Evaluation Report Daily Calibration Test
Environmental Protection Agency
Page 69 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: DAYCAL-19
Check Name: Upscale Reference Value Consistent with Span
Related Former Checks:
Applicability:
Description:
Validation Tables:
Test Tolerances (Cross Check Table)
Specifications:
For the daily calibration test with a Daily Cal Span Value that is not null and an UpscaleReferenceValue greater than 0:
Calculate Upscale Reference Percent of Span = UpscaleReferenceValue / Daily Cal Span Value * 100, and round to result to one
decimal place.
Locate the Test Tolerance cross-check record where the TestTypeCode is equal to "7DAY" and the FieldDescription is equal to
" GasPercentOfSpan".
If UpscaleGasLevelCode is equal to "MID", and the ComponentTypeCode of the associated component is not equal to "FLOW",
If Upscale Reference Percent of Span is less than 50.0 or greater than 60.0,
If Upscale Reference Percent of Span is less than 50.0 - Tolerance in the cross-check record or Upscale
Reference Percent of Span greater than 60.0 + Tolerance in the cross-check record,
return result A.
Otherwise,
return result B.
If UpscaleGasLevelCode is equal to "HIGH",
If the ComponentTypeCode of the associated component is equal to "FLOW",
If Upscale Reference Percent of Span is less than 50.0 or greater than 70.0,
If Upscale Reference Percent of Span is less than 50.0 - Tolerance in the cross-check record or Upscale
Reference Percent of Span greater than 70.0 + Tolerance in the cross-check record,
return result C.
Otherwise,
return result D.
Otherwise,
If Upscale Reference Percent of Span is greater than 100.0,
return result E
If Upscale Reference Percent of Span is less than 80.0,
If Upscale Reference Percent of Span is less than 80.0 - Tolerance in the cross-check record,
return result E.
Otherwise,
return result F.
Environmental Protection Agency
Page 70 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
A
B
C
D
Response Severity
The tag value of at least one Mid level reference signal or calibration gas for [key] is Critical Error Level 2
[percent] %, which does not meet the applicable performance specifications. The
concentration of the mid reference signal or calibration gas must be between 50.0% and
60.0% of the span value. The test is invalid.
The tag value of at least one Mid level reference signal or calibration gas for [key] is Non-Critical Error
[percent] %, which does not meet the applicable performance specifications. The
concentration of the 'mid' reference signal or calibration gas must be between 50.0%
and 60.0% of the span value.
The tag value of at least one High level reference signal for [key] is [percent] %, which Critical Error Level 2
does not meet the performance specifications of 40 CFR Part 75. The value of the high
reference signal for a flow component must be between 50.0% and 70.0% of the span
value. The test is invalid.
The tag value of at least one High level reference signal for [key] is [percent] %, which
does not meet the performance specifications of 40 CFR Part 75. The value of the 'high'
reference signal for a flow component must be between 50.0% and 70.0% of the span
value.
The tag value of at least one High level reference calibration gas for [key] is
[percent] %, which does not meet the applicable performance specifications. The
concentration of the high reference calibration gas must be between 80.0% and 100.0%
of the span value. The test is invalid.
The tag value of at least one High level reference calibration gas for [key] is
[percent] %, which does not meet the applicable performance specifications. The
concentration of the 'high' reference calibration gas must be between 80.0% and 100.0%
of the span value.
Non-Critical Error
Critical Error Level 2
Non-Critical Error
Usage:
1
Process/Category: Emissions Data Evaluation Report Daily Calibration Test
Environmental Protection Agency
Page 71 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: DAYCAL-20
Check Name: Calculate Zero Gas Injection or Reference Signal Results
Related Former Checks:
Applicability:
Description:
Validation Tables:
Test Tolerances (Cross Check Table)
Specifications:
For the daily calibration test with a zero injection:
If (Daily Cal Span Value is null, or ZeroReference Value of the test is null or is less than zero, or ZeroMeasuredValue of the test is
null)
Set Daily Cal Calc Result to "INVALID", Daily Cal Zero Injection Calc Result to null, Daily Cal Zero Injection Calc
APS Indicator to null, and return result A.
Otherwise,
Calculate dijf = abs(ZeroMeasuredValue - ZeroReference Value)
Set Daily Cal Zero Injection Calc APS Indicator to 0.
If (ComponentTypeCode of the associated component is equal to "C02" or "02")
Round dijf to 1 decimal place.
Set Daily Cal Zero Injection Calc Result to diff.
If {Daily Cal Calc Result is not equal to "INVALID" or "IGNORED")
If (Daily Cal Zero Injection Calc Result is greater than 1.0)
If (ZeroCalibrationError is greater than or equal to 0 and less than or equal to 1.0)
Locate the Test Tolerance cross-check record where the TestTypeCode is equal to
"7DAY" and the FieldDescription is equal to "DifferencePCT".
If (the absolute value of the difference between dijf and ZeroCalibrationError is less than
or equal to the Tolerance in the cross-check record)
if (Daily Cal Calc Result is not equal to "INC" or "FAILED")
set Daily Cal Calc Result to "PASSED".
else
set Daily Cal Calc Result to "FAILED".
If (Daily Cal Injection Times Valid == true)
If (Daily Cal Fail Date is null)
set Daily Cal Fail Date to ZeroInjectionDate.
set Daily Cal Fail Hour to Zerolnjection Hour,
else if (Daily Cal Fail Date/Daily Cal Fail Hour is greater than
Zerolnj ectionDate/ZeroInj ectionHour)
set Daily Cal Fail Date to ZeroInjectionDate.
set Daily Cal Fail Hour to Zerolnjection Hour.
else
set Daily Cal Calc Result to "FAILED".
If (Daily Cal Injection Times Valid == true)
If (Daily Cal Fail Date is null)
Environmental Protection Agency
Page 72 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
set Daily Cal Fail Date to ZeroInjectionDate.
set Daily Cal Fail Hour to Zerolnjection Hour,
else if (Daily Cal Fail Date/Daily Cal Fail Hour is greater than
ZeroInjectionDate/ZeroInjectionHour)
set Daily Cal Fail Date to ZeroInjectionDate.
set Daily Cal Fail Hour to Zerolnjection Hour.
else if (Daily Cal Calc Result is not equal to "INC" or "FAILED")
set Daily Cal Calc Result to "PASSED".
If (ComponentTypeCode of the associated component is equal to "S02" or "NOX")
Calculate Daily Cal Zero Injection Calc Result = min(round(
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
If (ZeroAPSIndicator is equal to 1 and ZeroCalibrationError is greater than or
equal to 0, and (Daily Cal Span Value is less than or equal to 50 AND
ZeroCalibrationError is less than or equal to 5.0) OR {Daily Cal Span Value is
greater than 50 AND Daily Cal Span Value is less than or equal to 200 AND
ZeroCalibrationError is less than or equal to 10.0)))
Locate the Test Tolerance cross-check record where the TestTypeCode
is equal to "7DAY" and the FieldDescription is equal to
"DifferencePPM".
If (the absolute value of the difference between diff and
ZeroCalibrationError is less than or equal to the Tolerance in the
cross-check record)
If {Daily Cal Calc Result is not equal to "INC" or "FAILED")
set Daily Cal Calc Result to "PASSAPS".
else
set Daily Cal Calc Result to "FAILED".
If {Daily Cal Injection Times Valid == true)
If {Daily Cal Fail Date is null)
set Daily Cal Fail Date to ZeroInjectionDate.
set Daily Cal Fail Hour to Zerolnjection Hour,
else if {Daily Cal Fail Date/Daily Cal Fail Hour is
greater than ZeroInjectionDate/ZeroInjectionHour)
set Daily Cal Fail Date to ZeroInjectionDate.
set Daily Cal Fail Hour to Zerolnjection Hour.
else
set Daily Cal Calc Result to "FAILED".
If {Daily Cal Injection Times Valid == true)
If {Daily Cal Fail Date is null)
set Daily Cal Fail Date to ZeroInjectionDate.
set Daily Cal Fail Hour to Zerolnjection Hour,
else if {Daily Cal Fail Date/Daily Cal Fail Hour is greater than
Zerolnj ectionDate/ZeroInj ectionHour)
set Daily Cal Fail Date to ZeroInjectionDate.
set Daily Cal Fail Hour to Zerolnjection Hour.
Otherwise,
If {Daily Cal Calc Result is not equal to "FAILED" or "INC" or "PASSAPS" or "IGNORED")
set Daily Cal Calc Result to "PASSED".
If (ComponentTypeCode of the associated component is equal to "FLOW")
Calculate Daily Cal Zero Injection Calc Result = min(round(diff / Daily Cal Span Value * 100, 1), 9999.9).
Round diff to 2 decimal places.
If {Daily Cal Zero Injection Calc Result is greater than 6.0, the SampleAcquisitionMethodCode of the associated
component is equal to "DP", and diff is less than or equal to 0.02)
set Daily Cal Zero Injection Calc Result to diff.
set Daily Cal Zero Injection Calc APS Indicator to 1.
If {Daily Cal Calc Result is not equal to "INVALID" or "FAILED" or "INC" or "IGNORED")
set Daily Cal Calc Result to "PASSAPS".
Environmental Protection Agency
Page 74 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Otherwise,
If {Daily Cal Zero Injection Calc Result is greater than 6.0)
If {Daily Cal Calc Result is not equal to "INVALID" or "IGNORED")
If (ZeroAPSIndicator is NOT equal to 1 and ZeroCalibrationError is greater than or equal
to 0 and less than or equal to 6.0)
Locate the Test Tolerance cross-check record where the TestTypeCode is equal
to "7DAY" and the FieldDescription is equal to "CalibrationError".
If (the absolute value of the difference between Daily Cal Zero Injection Calc
Result and ZeroCalibrationError is less than or equal to the Tolerance in the
cross-check record)
If {Daily Cal Calc Result is not equal to "PASS APS" or "INC" or
"FAILED")
set Daily Cal Calc Result to "PASSED".
Otherwise,
set Daily Cal Calc Result to "FAILED".
If {Daily Cal Injection Times Valid == true)
If {Daily Cal Fail Date is null)
set Daily Cal Fail Date to ZeroInjectionDate.
set Daily Cal Fail Hour to Zerolnjection Hour,
else if {Daily Cal Fail Date/Daily Cal Fail Hour is greater than
ZeroInjectionDate/ZeroInjectionHour)
set Daily Cal Fail Date to ZeroInjectionDate.
set Daily Cal Fail Hour to Zerolnjection Hour.
Otherwise,
If (ZeroAPSIndicator is equal to 1, the SampleAcquisitionMethodCode of the
associated component is equal to "DP", and ZeroCalibrationError is greater than
or equal to 0 and less than or equal to 0.02)
Locate the Test Tolerance cross-check record where the TestTypeCode
is equal to "7DAY" and the FieldDescription is equal to
"DifferenceINH20".
If (the absolute value of the difference between dijf and
ZeroCalibrationError is less than or equal to the Tolerance in the
cross-check record)
If {Daily Cal Calc Result is not equal to "INC" or "FAILED")
set Daily Cal Calc Result to "PASSAPS".
else
set Daily Cal Calc Result to "FAILED".
If {Daily Cal Injection Times Valid == true)
If {Daily Cal Fail Date is null)
set Daily Cal Fail Date to ZeroInjectionDate.
set Daily Cal Fail Hour to Zerolnjection Hour,
else if {Daily Cal Fail Date/Daily Cal Fail Hour is
greater than ZeroInjectionDate/ZeroInjectionHour)
set Daily Cal Fail Date to ZeroInjectionDate.
set Daily Cal Fail Hour to Zerolnjection Hour.
Environmental Protection Agency
Page 75 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
else
set Daily Cal Calc Result to "FAILED".
If {Daily Cal Injection Times Valid == true)
If (Daily Cal Fail Date is null)
set Daily Cal Fail Date to ZeroInjectionDate.
set Daily Cal Fail Hour to Zerolnjection Hour,
else if (Daily Cal Fail Date/Daily Cal Fail Hour is greater than
Zerolnj ectionDate/ZeroInj ectionHour)
set Daily Cal Fail Date to ZeroInjectionDate.
set Daily Cal Fail Hour to Zerolnjection Hour.
Otherwise,
If {Daily Cal Calc Result is not equal to "INC" or "FAILED", or "PASSAPS" or "IGNORED")
set Daily Cal Calc Result to "PASSED".
If (ComponentTypeCode of the associated component is equal to "HG")
Calculate Daily Cal Zero Injection Calc Result = min(round(
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
set Daily Cal Fail Date to ZeroInjectionDate.
set Daily Cal Fail Hour to Zerolnjection Hour.
Otherwise,
If (ZeroAPSIndicator is equal to 1 and ZeroCalibrationError is greater than or
equal to 0 and less than or equal to 1.0)
Locate the Test Tolerance cross-check record where the TestTypeCode
is equal to "7DAY" and the FieldDescription is equal to "Difference
UGSCM".
If (the absolute value of the difference between diff and
ZeroCalibrationError is less than or equal to the Tolerance in the
cross-check record)
If (Daily Cal Calc Result is not equal to "INC" or "FAILED")
set Daily Cal Calc Result to "PASSAPS".
else
set Daily Cal Calc Result to "FAILED".
If (Daily Cal Injection Times Valid == true)
If {Daily Cal Fail Date is null)
set Daily Cal Fail Date to ZeroInjectionDate.
set Daily Cal Fail Hour to Zerolnjection Hour,
else if {Daily Cal Fail Date/Daily Cal Fail Hour is
greater than ZeroInjectionDate/ZeroInjectionHour)
set Daily Cal Fail Date to ZeroInjectionDate.
set Daily Cal Fail Hour to Zerolnjection Hour.
set Daily Cal Calc Result to "FAILED".
If {Daily Cal Injection Times Valid == true)
If {Daily Cal Fail Date is null)
set Daily Cal Fail Date to ZeroInjectionDate.
set Daily Cal Fail Hour to Zerolnjection Hour,
else if {Daily Cal Fail Date/Daily Cal Fail Hour is greater than
ZeroInjectionDate/ZeroInjectionHour)
set Daily Cal Fail Date to ZeroInjectionDate.
set Daily Cal Fail Hour to Zerolnjection Hour.
Otherwise,
If {Daily Cal Calc Result is not equal to "FAILED" or "INC" or "PASSAPS" or "IGNORED")
set Daily Cal Calc Result to "PASSED".
Results:
Result Response Severity
A The software could not evaluate the [test] calculations reported for [key], because of the Informational Message
errors listed above.
Usage:
1 Process/Category: Emissions Data Evaluation Report Daily Calibration Test
Environmental Protection Agency
Page 77 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: DAYCAL-21
Check Name: Calculate Upscale Gas Injection or Reference Signal Results
Related Former Checks:
Applicability:
Description:
Validation Tables:
Test Tolerances (Cross Check Table)
Specifications:
For the daily calibration test with an upscale injection:
If (Daily Cal Span Value is null, or Daily Cal Upscale Gas Level Valid is false, or UpscaleReferenceValue of the test is null or is
less than or equal to zero, or UpscaleMeasuredValue of the test is null)
Set Daily Cal Calc Result to "INVALID", Daily Cal Upscale Injection Calc Result to null, Daily Cal Upscale Injection
Calc APS Indicator to null, and return result A.
Otherwise,
Calculate diff' = abs(UpscaleMeasuredValue - UpscaleReferenceValue)
Set Daily Cal Upscale Injection Calc APS Indicator to 0.
If (ComponentTypeCode of the associated component is equal to "C02" or "02")
Round diff to 1 decimal place.
Set Daily Cal Upscale Injection Calc Result to diff.
If (Daily Cal Calc Result is not equal to "INVALID" or "IGNORED")
If (Daily Cal Upscale Injection Calc Result is greater than 1.0)
If (UpscaleCalibrationError is greater than or equal to 0 and less than or equal to 1.0)
Locate the Test Tolerance cross-check record where the TestTypeCode is equal to
"7DAY" and the FieldDescription is equal to "DifferencePCT".
If (the absolute value of the difference between diff and UpscaleCalibrationError is less
than or equal to the Tolerance in the cross-check record)
if (Daily Cal Calc Result is not equal to "INC" or "FAILED")
set Daily Cal Calc Result to "PASSED".
else
set Daily Cal Calc Result to "FAILED".
If (Daily Cal Injection Times Valid == true)
If (Daily Cal Fail Date is null)
set Daily Cal Fail Date to UpscalelnjectionDate.
set Daily Cal Fail Hour to Upscalelnjection Hour,
else if (Daily Cal Fail Date/Daily Cal Fail Hour is greater than
UpscalelnjectionDate/UpscalelnjectionHour)
set Daily Cal Fail Date to UpscalelnjectionDate.
set Daily Cal Fail Hour to Upscalelnjection Hour.
else
set Daily Cal Calc Result to "FAILED".
If (Daily Cal Injection Times Valid == true)
Environmental Protection Agency Page 78 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
If (Daily Cal Fail Date is null)
set Daily Cal Fail Date to UpscalelnjectionDate.
set Daily Cal Fail Hour to Upscalelnjection Hour,
else if {Daily Cal Fail Date/Daily Cal Fail Hour is greater than
Upscalelnj ectionDate/Upscalelnj ectionHour)
set Daily Cal Fail Date to UpscalelnjectionDate.
set Daily Cal Fail Hour to Upscalelnjection Hour.
else if {Daily Cal Calc Result is not equal to "INC" or "FAILED" or "IGNORED")
set Daily Cal Calc Result to "PASSED".
If (ComponentTypeCode of the associated component is equal to "S02" or "NOX")
Calculate Daily Cal Upscale Injection Calc Result = min(round(
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
If (UpscaleAPSIndicator is equal to 1 and UpscaleCalibrationError is greater
than or equal to 0, and (Daily Cal Span Value is less than or equal to 50 AND
UpscaleCalibrationError is less than or equal to 5.0) OR (Daily Cal Span Value
is greater than 50 AND Daily Cal Span Value is less than or equal to 200 AND
UpscaleCalibrationError is less than or equal to 10.0)))
Locate the Test Tolerance cross-check record where the TestTypeCode
is equal to "7DAY" and the FieldDescription is equal to
"DifferencePPM".
If (the absolute value of the difference between diff and
UpscaleCalibrationError is less than or equal to the Tolerance in the
cross-check record)
If (Daily Cal Calc Result is not equal to "INC" or "FAILED")
set Daily Cal Calc Result to "PASSAPS".
else
set Daily Cal Calc Result to "FAILED".
If (Daily Cal Injection Times Valid == true)
If {Daily Cal Fail Date is null)
set Daily Cal Fail Date to
UpscalelnjectionDate.
set Daily Cal Fail Hour to Upscalelnjection
Hour.
else if (Daily Cal Fail Date/Daily Cal Fail Hour is
greater than
UpscalelnjectionDate/UpscalelnjectionHour)
set Daily Cal Fail Date to
UpscalelnjectionDate.
set Daily Cal Fail Hour to Upscalelnjection
Hour.
else
set Daily Cal Calc Result to "FAILED".
If {Daily Cal Injection Times Valid == true)
If {Daily Cal Fail Date is null)
set Daily Cal Fail Date to UpscalelnjectionDate.
set Daily Cal Fail Hour to Upscalelnjection Hour,
else if {Daily Cal Fail Date/Daily Cal Fail Hour is greater than
Upscalelnj ectionDate/Upscalelnj ectionHour)
set Daily Cal Fail Date to UpscalelnjectionDate.
set Daily Cal Fail Hour to Upscalelnjection Hour.
Otherwise,
If {Daily Cal Calc Result is not equal to "FAILED" or "INC", or "PASSAPS" or "IGNORED")
set Daily Cal Calc Result to "PASSED".
If (ComponentTypeCode of the associated component is equal to "FLOW")
Calculate Daily Cal Upscale Injection Calc Result = min(round(dilf / Daily Cal Span Value * 100, 1), 9999.9).
Round diff to 2 decimal places.
If {Daily Cal Upscale Injection Calc Result is greater than 6.0, the SampleAcquisitionMethodCode of the
associated component is equal to "DP", and diff is less than or equal to 0.02)
Environmental Protection Agency
Page 80 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
set Daily Cal Upscale Injection Calc Result to diff.
set Daily Cal Upscale Injection Calc APS Indicator to 1.
If {Daily Cal Calc Result is not equal to "INVALID" or "FAILED" or "INC" or "IGNORED")
set Daily Cal Calc Result to "PASSAPS".
Otherwise,
If (Daily Cal Upscale Injection Calc Result is greater than 6 .0)
If {Daily Cal Calc Result is not equal to "INVALID" or "IGNORED")
If (UpscaleAPSIndicator is NOT equal to 1 and UpscaleCalibrationError is greater than
or equal to 0 and less than or equal to 6.0)
Locate the Test Tolerance cross-check record where the TestTypeCode is equal
to "7DAY" and the FieldDescription is equal to "CalibrationError".
If (the absolute value of the difference between Daily Cal Upscale Injection
Calc Result and UpscaleCalibrationError is less than or equal to the Tolerance in
the cross-check record)
If {Daily Cal Calc Result is not equal to "PASS APS" or "INC" or
"FAILED")
set Daily Cal Calc Result to "PASSED".
Otherwise,
set Daily Cal Calc Result to "FAILED".
If {Daily Cal Injection Times Valid == true)
If {Daily Cal Fail Date is null)
set Daily Cal Fail Date to UpscalelnjectionDate.
set Daily Cal Fail Hour to Upscalelnjection Hour,
else if {Daily Cal Fail Date/Daily Cal Fail Hour is greater than
Upscalelnj ectionDate/Upscalelnj ectionHour)
set Daily Cal Fail Date to UpscalelnjectionDate.
set Daily Cal Fail Hour to Upscalelnjection Hour.
Otherwise,
If (UpscaleAPSIndicator is equal to 1, the Sample AcquisitionMethodCode of the
associated component is equal to "DP", and UpscaleCalibrationError is greater
than or equal to 0 and less than or equal to 0.02)
Locate the Test Tolerance cross-check record where the TestTypeCode
is equal to "7DAY" and the FieldDescription is equal to
"DifferenceINH20".
If (the absolute value of the difference between diff and
UpscaleCalibrationError is less than or equal to the Tolerance in the
cross-check record)
If {Daily Cal Calc Result is not equal to "INC" or "FAILED")
set Daily Cal Calc Result to "PASSAPS".
else
set Daily Cal Calc Result to "FAILED".
If {Daily Cal Injection Times Valid == true)
Environmental Protection Agency
Page 81 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
If (Daily Cal Fail Date is null)
set Daily Cal Fail Date to
UpscalelnjectionDate.
set Daily Cal Fail Hour to Upscalelnjection
Hour.
else if (Daily Cal Fail Date/Daily Cal Fail Hour is
greater than
UpscalelnjectionDate/UpscalelnjectionHour)
set Daily Cal Fail Date to
UpscalelnjectionDate.
set Daily Cal Fail Hour to Upscalelnjection
Hour.
else
set Daily Cal Calc Result to "FAILED".
If (Daily Cal Injection Times Valid == true)
If (Daily Cal Fail Date is null)
set Daily Cal Fail Date to UpscalelnjectionDate.
set Daily Cal Fail Hour to Upscalelnjection Hour,
else if (Daily Cal Fail Date/Daily Cal Fail Hour is greater than
UpscalelnjectionDate/UpscalelnjectionHour)
set Daily Cal Fail Date to UpscalelnjectionDate.
set Daily Cal Fail Hour to Upscalelnjection Hour.
Otherwise,
If {Daily Cal Calc Result is not equal to "INC" or "FAILED", or "PASSAPS" or "IGNORED")
set Daily Cal Calc Result to "PASSED".
If (ComponentTypeCode of the associated component is equal to "HG")
Calculate Daily Cal Upscale Injection Calc Result = inin(round(t//// / Daily Cal Span Value * 100, 1), 9999.9)
Round diff to 1 decimal places.
If (Daily Cal Upscale Injection Calc Result is greater than 5.0, AND diff is less than or equal to 1.0)
set Daily Cal Upscale Injection Calc Result to diff.
set Daily Cal Upscale Injection Calc APS Indicator to 1.
If (Daily Cal Calc Result is not equal to "INVALID" or "FAILED" or "INC" or "IGNORED")
set Daily Cal Calc Result to "PASSAPS".
Otherwise,
If (Daily Cal Upscale Injection Calc Result is greater than 5 .0)
If {Daily Cal Calc Result is not equal to "INVALID" or "IGNORED")
If (UpscaleAPSIndicator is NOT equal to 1 and UpscaleCalibrationError is greater than
or equal to 0 and less than or equal to 5.0)
Locate the Test Tolerance cross-check record where the TestTypeCode is equal
to "7DAY" and the FieldDescription is equal to "CalibrationError".
If (the absolute value of the difference between Daily Cal Upscale Injection
Calc Result and UpscaleCalibrationError is less than or equal to the Tolerance in
the cross-check record)
If {Daily Cal Calc Result is not equal to "PASSAPS" or "INC" or
Environmental Protection Agency
Page 82 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
"FAILED")
set Daily Cal Calc Result to "PASSED".
Otherwise,
set Daily Cal Calc Result to "FAILED".
If {Daily Cal Injection Times Valid == true)
If (Daily Cal Fail Date is null)
set Daily Cal Fail Date to UpscalelnjectionDate.
set Daily Cal Fail Hour to Upscalelnjection Hour,
else if (Daily Cal Fail Date/Daily Cal Fail Hour is greater than
UpscalelnjectionDate/UpscalelnjectionHour)
set Daily Cal Fail Date to UpscalelnjectionDate.
set Daily Cal Fail Hour to Upscalelnjection Hour.
Otherwise,
If (UpscaleAPSIndicator is equal to 1 and UpscaleCalibrationError is greater
than or equal to 0 AND UpscaleCalibrationError is less than or equal to 1.0)
Locate the Test Tolerance cross-check record where the TestTypeCode
is equal to "7DAY" and the FieldDescription is equal to
"DifferenceUGSCM".
If (the absolute value of the difference between diff and
UpscaleCalibrationError is less than or equal to the Tolerance in the
cross-check record)
If (Daily Cal Calc Result is not equal to "INC" or "FAILED")
set Daily Cal Calc Result to "PASSAPS".
else
set Daily Cal Calc Result to "FAILED".
If (Daily Cal Injection Times Valid == true)
If {Daily Cal Fail Date is null)
set Daily Cal Fail Date to
UpscalelnjectionDate.
set Daily Cal Fail Hour to Upscalelnjection
Hour.
else if {Daily Cal Fail Date/Daily Cal Fail Hour is
greater than
UpscalelnjectionDate/UpscalelnjectionHour)
set Daily Cal Fail Date to
UpscalelnjectionDate.
set Daily Cal Fail Hour to Upscalelnjection
Hour.
else
set Daily Cal Calc Result to "FAILED".
If {Daily Cal Injection Times Valid == true)
If {Daily Cal Fail Date is null)
set Daily Cal Fail Date to UpscalelnjectionDate.
set Daily Cal Fail Hour to Upscalelnjection Hour,
else if {Daily Cal Fail Date/Daily Cal Fail Hour is greater than
Upscalelnj ectionDate/Upscalelnj ectionHour)
set Daily Cal Fail Date to UpscalelnjectionDate.
Environmental Protection Agency
Page 83 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
set Daily Cal Fail Hour to Upscalelnjection Hour.
Otherwise,
ff {Daily Cal Calc Result is not equal to "FAILED" or "INC", or "PASSAPS" or "IGNORED")
set Daily Cal Calc Result to "PASSED".
Results:
Result Response Severity
A The software could not evaluate the [test] calculations reported for [key], because of the Informational Message
errors listed above.
Usage:
1 Process/Category: Emissions Data Evaluation Report Daily Calibration Test
Environmental Protection Agency
Page 84 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
DAYCAL-22
Check Name:
Daily Calibration Test End Time Valid
Related Former Checks:
Applicability:
Description:
Specifications:
For the daily calibration test with upscale and zero injections and a valid date, hour, and minute and injection times:
If Date, Hour, and Minute of the test does not equal the later of the ZeroInjectionDate, Hour, and Minute (if not null) and the
UpscalelnjectionDate, Hour, and Minute (if non-null),
return result A.
Results:
Result
A
You reported a test Date, Hour, and Minute that is not the same as the Date, Hour, and Critical Error Level 1
Minute of the last injection in the daily calibration test for [key].
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Daily Calibration Test
Environmental Protection Agency
Page 85 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
DAYCAL-23
Check Name:
Reported Zero Injection Results Consistent with Recalculated Values
Related Former Checks:
Applicability:
Description:
Validation Tables:
Test Tolerances (Cross Check Table)
Specifications:
For the daily calibration test with a zero injection:
If the ZeroAPSIndicator is equal to 1, the ComponentTypeCode of the associated component is equal to "FLOW", and the
SampleAcquisitionMethodCode of the associated component is not equal to "DP",
return result A.
If the ZeroAPSIndicator is equal to 1, the ComponentTypeCode of the associated component is equal to "S02" or "NOX", and the
Daily Cal Span Value is greater than or equal to 200,
return result B.
If the ZeroAPSIndicator is equal to 1, the ComponentTypeCode of the associated component is equal to "C02" or "02",
return result C.
Otherwise,
If Daily Cal Zero Injection Calc Result is not null,
If the ZeroAPSIndicator in the current record is not equal to 1 and the Daily Cal Zero Injection Calc APS
Indicator is equal to 1,
return result D.
If the ZeroCalibrationError is greater than or equal to 0,
If the ComponentTypeCode of the associated component is equal to "C02" or "02"
Locate the Test Tolerance cross-check record where the TestTypeCode is equal to "7DAY" and
the FieldDescription is equal to "DifferencePCT".
If the absolute value of the difference between the Daily Cal Zero Injection Calc Result and the
ZeroCalibrationError is greater than the Tolerance in the cross-check record,
return result E.
If the Daily Cal Zero Injection Calc APS Indicator is equal to 1,
If the ComponentTypeCode of the associated component is equal to "FLOW",
Locate the Test Tolerance cross-check record where the TestTypeCode is equal to
"7DAY" and the FieldDescription is equal to "DifferenceINH20".
If the absolute value of the difference between the Daily Cal Zero Injection Calc Result
and the ZeroCalibrationError is greater than the Tolerance in the cross-check record,
return result E.
Else, If the ComponentTypeCode of the associated component is equal to "HG",
Locate the Test Tolerance cross-check record where the TestTypeCode is equal to
"7DAY" and the FieldDescription is equal to "DifferenceUGSCM".
Environmental Protection Agency
Page 86 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
If the absolute value of the difference between the Daily Cal Zero Injection Calc Result
and the ZeroCalibrationError is greater than the Tolerance in the cross-check record,
return result E.
Otherwise,
Locate the Test Tolerance cross-check record where the TestTypeCode is equal to
"7DAY" and the FieldDescription is equal to "DifferencePPM".
If the absolute value of the difference between the Daily Cal Zero Injection Calc Result
and the ZeroCalibrationError is greater than the Tolerance in the cross-check record,
return result E.
else if ZeroAPSIndicator is equal to 0,
Locate the Test Tolerance cross-check record where the TestTypeCode is equal to "7DAY" and
the FieldDescription is equal to "CalibrationError".
If the absolute value of the difference between the Daily Cal Zero Injection Calc Result and the
ZeroCalibrationError is greater than the Tolerance in the cross-check record,
return result F.
Results:
Result
A
B
C
D
E
F
Response
You reported a value of " 1" as the [level] AP S Indicator for [key], but you must use the
standard performance criteria for non-differential pressure flow monitors.
You reported a value of " 1" as the [level] AP S Indicator for [key], but you must use the
standard performance specification criteria for S02 and NOX components when the
instrument span is greater than or equal to 200.
You reported a value of " 1" as the [level] AP S Indicator for [key], but you must use the
standard performance specification criteria for C02 and 02 components.
You did not report a value of "1" in the [level] APS Indicator for [key], although EPA
applied the alternative performance specification to determine that the injection passed
the applicable performance specification.
The absolute difference reported as the [level] Calibration Error for [key] is inconsistent
with the recalculated absolute difference for the gas injection or reference signal.
The [level] Calibration Error reported for [key] is inconsistent with the recalculated
calibration error for the gas injection or reference signal.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1
Process/Category: Emissions Data Evaluation Report Daily Calibration Test
Environmental Protection Agency
Page 87 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
DAYCAL-24
Check Name:
Reported Upscale Injection Results Consistent with Recalculated Values
Related Former Checks:
Applicability:
Description:
Validation Tables:
Test Tolerances (Cross Check Table)
Specifications:
For the daily calibration test with an upscale injection:
If the UpscaleAPSIndicator is equal to 1, the ComponentTypeCode of the associated component is equal to "FLOW", and the
SampleAcquisitionMethodCode of the associated component is not equal to "DP",
return result A.
If the UpscaleAPSIndicator is equal to 1, the ComponentTypeCode of the associated component is equal to "S02" or "NOX", and
the Daily Cal Span Value is greater than or equal to 200,
return result B.
If the UpscaleAPSIndicator is equal to 1, the ComponentTypeCode of the associated component is equal to "C02" or "02",
return result C.
Otherwise,
If Daily Cal Upscale Injection Calc Result is not null,
If the UpscaleAPSIndicator in the current record is not equal to 1 and the Daily Cal Upscale Injection Calc APS
Indicator is equal to 1,
return result D.
If the UpscaleCalibrationError is greater than or equal to 0,
If the ComponentTypeCode of the associated component is equal to "C02" or "02"
Locate the Test Tolerance cross-check record where the TestTypeCode is equal to "7DAY" and
the FieldDescription is equal to "DifferencePCT".
If the absolute value of the difference between the Daily Cal Upscale Injection Calc Result and
the UpscaleCalibrationError is greater than the Tolerance in the cross-check record,
return result E.
If the Daily Cal Upscale Injection Calc APS Indicator is equal to 1,
If the ComponentTypeCode of the associated component is equal to "FLOW",
Locate the Test Tolerance cross-check record where the TestTypeCode is equal to
"7DAY" and the FieldDescription is equal to "DifferenceINH20".
If the absolute value of the difference between the Daily Cal Upscale Injection Calc
Result and the UpscaleCalibrationError is greater than the Tolerance in the cross-check
record,
return result E.
Else, if the ComponentTypeCode of the associated component is equal to "HG",
Locate the Test Tolerance cross-check record where the TestTypeCode is equal to
Environmental Protection Agency
Page 88 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
"7DAY" and the FieldDescription is equal to "DifferenceUGSCM".
If the absolute value of the difference between the Daily Cal Upscale Injection Calc
Result and the UpscaleCalibrationError is greater than the Tolerance in the cross-check
record,
return result E.
Otherwise,
Locate the Test Tolerance cross-check record where the TestTypeCode is equal to
"7DAY" and the FieldDescription is equal to "DifferencePPM".
If the absolute value of the difference between the Daily Cal Upscale Injection Calc
Result and the UpscaleCalibrationError is greater than the Tolerance in the cross-check
record,
return result E.
else if Upscale APSIndicator is equal to 0,
Locate the Test Tolerance cross-check record where the TestTypeCode is equal to "7DAY" and
the FieldDescription is equal to "CalibrationError".
If the absolute value of the difference between the Daily Cal Upscale Injection Calc Result and
the UpscaleCalibrationError is greater than the Tolerance in the cross-check record,
return result F.
Results:
Result
A
B
C
D
E
F
Usage:
1
Response
You reported a value of " 1" as the [level] AP S Indicator for [key], but you must use the
standard performance criteria for non-differential pressure flow monitors.
You reported a value of " 1" as the [level] AP S Indicator for [key], but you must use the
standard performance specification criteria for S02 and NOX components when the
instrument span is greater than or equal to 200.
You reported a value of " 1" as the [level] AP S Indicator for [key], but you must use the
standard performance specification criteria for C02 and 02 components.
You did not report a value of "1" in the [level] APS Indicator for [key], although EPA
applied the alternative performance specification to determine that the injection passed
the applicable performance specification.
The absolute difference reported as the [level] Calibration Error for [key] is inconsistent
with the recalculated absolute difference for the gas injection or reference signal.
The [level] Calibration Error reported for [key] is inconsistent with the recalculated
calibration error for the gas injection or reference signal.
Process/Category: Emissions Data Evaluation Report Daily Calibration Test
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 89 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: DAYCAL-25
Check Name: Determination of Overall Daily Calibration Test Result
Related Former Checks:
Applicability:
Description:
Specifications:
For the daily calibration test:
If Daily Cal Calc Result is equal to "INVALID",
set Daily Cal Calc Result to null.
If TestResultCode is null,
return result A.
If TestResultCode is not equal to "PASSED", "PASSAPS", "FAILED", "INC", or "ABORTED",
return result B.
If Daily Cal Calc Result is equal to "FAILED",
If TestResultCode is equal to "PASSED" or "PASSAPS",
return result C.
If TestResultCode is equal to "INC",
return result D.
If Daily Cal Calc Result is equal to "PASSED" or "PASSAPS", and the TestResultCode is equal to "FAILED",
return result E.
Results:
Result
A
B
C
D
Response
You did not provide [fieldname], which is required for [key].
You reported the value [value], which is not in the list of valid values for this test type,
in the field [fieldname] for [key].
The TestResultCode for [key] indicates a passing test, but the recalculated results
indicate a failing test.
The TestResultCode for [key] indicates an incomplete test, but the recalculated results
indicate a failing test. A test is considered to have failed if it fails to meet the
performance criteria for any injection.
You reported a TestResultCode of "FAILED" for [key], but the results recalculated or
determined from the other reported values indicate that the test passed.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1
Process/Category: Emissions Data Evaluation Report Daily Calibration Test
Environmental Protection Agency
Page 90 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: DAYCAL-26
Check Name: Upscale Gas Type Code Valid
Related Former Checks:
Applicability:
Description:
Validation Tables:
Gas Type Code (Lookup Table)
Vw System Parameter (Lookup Table)
Specifications:
For the daily calibration test with an upscale injection:
UpscaleGasTypeValid = true.
Locate System Parameter lookup table record where Sys Param Name = 'PGVPAETBRULEDATE'.
Set Daily Cal PGVP Rule Date to System ParameterPwarn_Valuel.
If UpscaleGasTypeCode is null,
If the ComponentTypeCode of the associated component is equal to "S02", "NOX", "C02", or "02", and the Date of the
test is on or after 9/26/2011,
UpscaleGasTypeValid = false,
return result A.
Otherwise,
If the ComponentTypeCode of the associated component is equal to "FLOW" or "HG",
UpscaleGasTypeValid = false
return result B.
else if the UpscaleGasTypeCode is not equal to "GMIS", "PRM", "RGM", or "SRM",
if the UpscaleGasTypeCode is not in the GasTypeCode lookup table.
UpscaleGasTypeValid = false
return result C.
else if the UpscaleGasTypeCode == "ZERO" or "ZAM"
UpscaleGasTypeValid = false
return result C
else if the UpscaleGasTypeCode == "APPVD"
return result D
else if the ComponentTypeCode == "S02", "NOX", "C02" or "02",
Locate Protocol Gas Parameter To Type Cross Reference records where ProtocolGasParameter is equal
to ComponentTypeCode in the current Daily Calibration record, and GasTypeList contains the
UpscaleGasTypeCode in the current Daily Calibration record.
If not found,
UpscaleGasTypeValid = false
return result E.
else if ComponentTypeCode == "02", UpscaleGasTypeCode == "AIR", and the UpscaleGasCode is not
equal to "HIGH",
Environmental Protection Agency
Page 91 of 850
-------
Draft ECMPS Emissions Check Specifications
UpscaleGasTypeValid = false
return result F.
6/17/2015 12:00:00AM
Results:
Result
A
B
C
D
E
F
Response
You did not report a UpscaleGasTypeCode for [key]. This information is required by
the Protocol Gas Verification Program reporting rule.
You reported a value in the UpscaleGasTypeCode field for [key]. This value should
not be reported for a FLOW or HG component.
You reported the value [value], which is not in the list of valid values, in the field
[fieldname] for [key].
You reported "APPVD" as the [fieldname] for [key]. This code indicates that you
received approval from EPA for a new type of Protocol Gas. If you have not received
approval from EPA, please contact ECMPS support. If you have already received
approval, you should log in to the ECMPS host, so that the ECMPS program can obtain
the necessary information to override this error.
You reported an UpscaleGasTypeCode that is not appropriate for a [comptype]
component for [key].
You reported an [fieldname] cf "AIR" for [key], which indicates the use of purified air
material, but this material can only be used for a high-level calibration.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1
Process/Category: Emissions Data Evaluation Report Daily Calibration Test
Environmental Protection Agency
Page 92 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: DAYCAL-27
Check Name: Cylinder ID Valid
Related Former Checks:
Applicability:
Description:
Specifications:
For the daily calibration test with an upscale injection:
If CylinderlD is null,
If UpscaleGasTypeValid is true, and the UpscaleGasTypeCode is not null and not equal to "AIR",
return result A.
Otherwise,
If the UpscaleGasTypeCode is equal to "AIR",
return result B.
else if UpscaleGasTypeValid is true, and the UpscaleGasTypeCd is null,
return result C.
Results:
Result Response Severity
A You did not provide [fieldname], which is required for [key]. Critical Error Level 1
B You indicated that you used purified air material or zero air material instead of a Critical Error Level 1
cylinder gas, but you reported a Cylinderldentifier.
C You reported a [fieldname] for [key], but you did not report an UpscaleGasTypeCode. Non-Critical Error
Usage:
1 Process/Category: Emissions Data Evaluation Report Daily Calibration Test
Environmental Protection Agency
Page 93 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: DAYCAL-28
Check Name: Vendor ID Valid
Related Former Checks:
Applicability:
Description:
Validation Tables:
Protocol Gas Vendor (Lookup Table)
Specifications:
For the daily calibration test with an upscale injection:
If VendorlD is null,
If UpscaleGasTypeValid is true, and the UpscaleGasTypeCode is not null and not equal to "AIR", "SRM", "NTRM",
"GMIS", "RGM", or "PRM",
return result A.
else if the VendorlD is not in the Protocol Gas Vendor lookup table,
return result B.
Otherwise,
If the UpscaleGasTypeCode is equal to "AIR", "SRM", "NTRM", "GMIS", "RGM", or "PRM",
return result C.
else if the DeactivationDate in the Protocol Gas Vendor record is not null and the Date of the current test is on or after the
January 1 after DeactivationDate + 8 years,
return result F.
else if the VendorlD is equal to "NONPGVP", and the Date of the test is on or after the Daily Cal PGVPRule Date + 60
days + 8 years,
return result D.
Results:
Result
A
B
C
D
E
F
Usage:
1
else if UpscaleGasTypeValid is true, and the UpscaleGasTypeCd is null,
return result E.
Response
You did not provide [fieldname], which is required for [key].
You reported a Vendorldentifier of [value], which is not in the list of Protocol Gas
Vendors, for [key]. Please visit the ECMPS Support Website for the list of Protocol
Gas Vendors.
You reported a [fieldname] for [key], but this value should only be reported for an EPA
Protocol Gas Type. The cylinder gas type of [gastype] indicates the use of a non-EPA
Protocol Gas Type.
You reported a Vendorldentifier of "NONPGVP" for [key], indicating the use of a EPA
Protocol Gas Type purchased from a vendor not participating in the Protocol Gas
Vendor Program (PGVP). You cannot use a gas purchased from a non-participating
vendor that was acquired more than 60 days after the PGVP Effective Date.
You reported a [fieldname] for [key], but you did not report an UpscaleGasTypeCode.
You have reported a Vendorldentifier for [key] of a vendor who is no longer
participating in the Protocol Gas Verification Program.
Process/Category: Emissions Data Evaluation Report Daily Calibration Test
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 2
Non-Critical Error
Critical Error Level 2
Environmental Protection Agency
Page 94 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
DAYCAL-29
Check Name:
Cylinder Expiration Date Valid
Related Former Checks:
Applicability:
Description:
Specifications:
For the daily calibration test with an upscale injection:
If ExpirationDate is null,
If UpscaleGasTypeValid is true, and the UpscaleGasTypeCode is not null and not equal to "AIR",
return result A.
Otherwise,
If the UpscaleGasTypeCode is equal to "AIR",
return result B.
else if the ExpirationDate is prior to the Date of the test,
return result C.
else if the ExpirationDate is more than 8 years after the Date of the test,
return result D.
else if UpscaleGasTypeValid is true, and the UpscaleGasTypeCd is null,
return result E.
Results:
Result
A
B
Response
You did not provide [fieldname], which is required for [key].
You reported a [fieldname] for [key], but this value should only be reported for an EPA
Protocol Gas Type. The cylinder gas type of [gastype] indicates the use of a non-EPA
Protocol Gas Type.
You reported an ExpirationDate for the cylinder that is prior to the date of the test for
[key].
You reported an ExpirationDate for the cylinder that is more than eight years after the
date of the test for [key]. Gas cylinders expire in less than eight years.
You reported a [fieldname] for [key], but you did not report an UpscaleGasTypeCode.
Severity
Critical Error Level 1
Critical Error Level 1
C
Critical Error Level 2
D
Critical Error Level 2
E
Non-Critical Error
Usage:
1 Process/Category: Emissions Data Evaluation Report Daily Calibration Test
Environmental Protection Agency
Page 95 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
DAYCAL-30
Check Name:
Upscale Gas Type Code Components Valid
Related Former Checks:
Applicability:
Description:
Validation Tables:
Vw System Parameter (Lookup Table)
Specifications:
For the daily calibration test with an upscale injection:
UpscaleGasTypeValid = true.
Locate System Parameter lookup table record where Sys Param Name = 'PGVP AETB RULE DATE'.
Set Daily Cal PGVP Rule Date to System ParameterPwarn_Valuel.
If UpscaleGasTypeCode is null,
If the ComponentTypeCode of the associated component is equal to "S02", "NOX", "C02", or "02", and the Date of the
test is on or after 9/26/2011,
UpscaleGasTypeValid = false,
return result A.
Set Protocol Gas Invalid Component List to null.
Set Protocol Gas Exclusive Component List to null.
Set Protocol Gas Balance Component List to null.
Set Protocol Gas Duplicate Component List to null.
Set Protocol Gas Component List to null.
Set Protocol Gas Approval Requested = true.
Set Protocol Gas Component Count to 0.
Set Balance Component Count to 0.
For each GasComponentCode in UpscaleGasTypeCode ,
Locate a record in the GasComponentCodeLookupTable where GasComponentCode is equal to the
GasComponentCode in the UpscaleGasTypeCode .
If not found, or GasComponentCode is equal to "ZERO",
Add GasComponentCode to Protocol Gas Invalid Component List.
Else
If CanCombinelndicator is equal to 0,
Add GasComponentCode to Protocol Gas Exclusive Component List.
Otherwise,
If the ComponentTypeCode of the associated component is equal to "FLOW"or "HG",
UpscaleGasTypeValid = false
return result B.
Else
If BalanceComponentlndicator is equal to 1,
Environmental Protection Agency
Page 96 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Add GasComponentCode to Protocol Gas Balance Component List.
Increament Balance Component Count by 1.
If the GasComponentCode is equal to "APPVD",
Set Protocol Gas Approval Requested = true.
If GasComponentCode is not in Protocol Gas Component List,
add GasComponentCode to Protocol Gas Component List.
Else if GasComponentCode is not in Protocol Gas Duplicate Component List,
add GasComponentCode to Protocol Gas Duplicate Component List.
Increament Protocol Gas Component Count by 1.
If Protocol Gas Invalid Component List is not null,
UpscaleGasTypeValid = false
return result C.
Else if Protocol Gas Duplicate Component List is not null,
set Protocol Gas Component List Valid = false,
return result L.
Else if Protocol Gas Exclusive Component List is not null, and Protocol Gas Component Count is greater than 1,
UpscaleGasTypeValid = false
return result D.
Else if Protocol Gas Approval Requested is equal to true,
return result E.
Else if Protocol Gas Exclusive Component List is null, and Balance Component Count is equal to 0,
set UpscaleGasTypeValid = false,
return result J.
Else if Protocol Gas Exclusive Component List is null, and Balance Component Count is greater than 1,
set UpscaleGasTypeValid = false,
return result K.
Else if the UpscaleGasTypeCode is not equal to "GMIS", "NTRM", "PRM", "RGM", or "SRM",
If the ComponentTypeCode is equal to "S02" or "C02",
If no GasComponentCode in UpscaleGasTypeCode is equal to ComponentTypeCode,
UpscaleGasTypeValid = false
return result F.
Else if the ComponentTypeCode is equal to "02",
If UpscaleGasTypeCode is not equal to "AIR", and no GasComponentCode in
UpscaleGasTypeCode is equal to "02",
UpscaleGasTypeValid = false
return result G.
Else if UpscaleGasTypeCode is equal to "AIR", and the UpscaleGasCode is not equal to "HIGH",
UpscaleGasTypeValid = false
return result H.
Else if the ComponentTypeCode is equal to "NOX",
Environmental Protection Agency
Page 97 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
If no GasComponentCode in GasTypeCode is equal to "NO" or "N02",
UpscaleGasTypeValid = false
return result I.
Results:
Result
A
B
C
D
E
F
G
H
I
J
K
Usage:
1
Response
You did not report a UpscaleGasTypeCode for [key]. This information is required by
the Protocol Gas Verification Program reporting rule.
You reported a value in the UpscaleGasTypeCode field for [key]. This value should
not be reported for a FLOW or HG component.
You reported the values ([invalidlist]), in the field [fieldname] for [key], which are not
in the list of valid values.
You reported multiple gas components in the field [fieldname] for [key] that include
values ([exclusivelist]) that you should report by themselves.
You reported "APPVD" as the [fieldname] for [key]. This code indicates that you
received approval from EPA for a new type of Protocol Gas. If you have not received
approval from EPA, please contact ECMPS support. If you have already received
approval, you should log in to the ECMPS host, so that the ECMPS program can obtain
the necessary information to override this error.
You reported an UpscaleGasTypeCode that is not appropriate for a [comptype]
component for [key].
You reported an UpscaleGasTypeCode that is not appropriate for a [comptype]
component for [key].
You reported an [fieldname] cf "AIR" for [key], which indicates the use of purified air
material, but this material can only be used for a high-level calibration.
You reported an UpscaleGasTypeCode that is not appropriate for a [comptype]
component for [key].
You reported an UpscaleGasTypeCode that does not contain a PGVP balance
component. A single balance component is required when reporting other individual
gas components.
You reported an UpscaleGasTypeCode that contains multiple PGVP balance
components ([balancelist]). A single balance component is required when reporting
other individual gas components.
Your reported one or more duplicate gas component records.
Process/Category: Emissions Data Evaluation Report Daily Calibration Test
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 98 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Category:
Daily Emissions Data
Environmental Protection Agency
Page 99 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
DAILY-1
Check Name:
Determine Need for Daily C02 Emissions Record
Related Former Checks:
Applicability:
Description:
Specifications:
Current C02 Mass Daily Record = null
Daily Op Time = null
if (Daily Op Time Accumulator Array for the location >= 0)
Daily Op Time = Daily Op Time Accumulator Array for the location
Daily Op Time Accumulator Array for the location = 0.
C02 Method Count = Active records in MonitoringMethodData for the location and date where
ParameterCode begins with "C02"
FSA Method Count = Active records in MonitoringMethodData for the location and date where
ParameterCode = "C02M" and MethodCode = "FSA"
if (FSA Method Count > 0 AND C02 Method Count >1)
return result A
if (FSA Method Count > 0)
Expected Summary Value for C02 Array for the location = true
C02 Mass Daily Emissions Count = count of DailyEmissionsData records with ParameterCode = "C02M" where
Current Date = DailyEmissionsData.Date
if (C02 Mass Daily Emissions Count > 1)
Rpt Period C02 Mass Reported Accumulator Array for the location = -1
Rpt Period C02 Mass Calculated Accumulator Array for the location = -1
return result B
else if (FSA Method Count == 0 AND C02 Mass Daily Emissions Count > 0)
return result C
else if (FSA Method Count > 0 AND C02 Mass Daily Emissions Count == 0 AND Daily Op Time > 0
return result D
else if (FSA Method Count > 0 AND C02 Mass Daily Emissions Count ==1)
Current C02 Mass Daily Record = matching DailyEmissionsData record
else
If (Daily Op Time == 0)
return result E
Environmental Protection Agency
Page 100 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
B
C
D
E
Usage:
1
Response
You have reported more than one active method to determine C02 emissions in your
monitoring plan for this date.
You reported more than one Daily Emissions record for [param] for the day.
You reported a Daily Emissions record for C02M, but you did not report an active
C02M FSA method record in your monitoring plan for the day.
You did not report a Daily Emissions record for C02M for the day.
You reported a Daily Emissions record for C02M, but this is not appropriate for a
non-operating day.
Process/Category: Emissions Data Evaluation Report C02 Daily Emissions
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 101 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: DAILY-2
Check Name: Check Total Daily Emissions Value
Related Former Checks:
Applicability:
Description:
Validation Tables:
Hourly Emissions Tolerances (Cross Check Table)
Specifications:
Set Calc TDE to null.
If (Current CO2 Mass Daily Record is not null)
If (Current C02 Mass I) aily To ta 1D a i ly E m i s s i o n s >= 0 AND Rpt Period C02 Mass Reported Accumulator Array for the
location >= 0)
Rpt Period C02 Mass Reported Accumulator Array for the location = Rpt Period C02 Mass Reported Accumulator
Array for the location + Current C02 Mass Daily Tota 1Da i ly E mi ssions
if (Current C02 Mass Daily Record. U nadj ustcdDa i ly Emi ssio ns is not null OR Calc CO2 Unadj is not null)
if (Current C02 Mass Daily /?6'ew= 0)
Calc TDE = Calc TDE + Current C02 Mass Daily /?6'cmy/. SorbcntRclatcdMassEmissions
else
Set Calc TDE to null.
else if (Current C02 Mass Daily Ttecon/.UnadjustedDailyEmissions is null AND Legacy Data Evaluation == true AND Current
C02 Mass Daily /?6'cmy/.Tota 1Da i ly Emi ssio ns >= 0)
Calc TDE = Current C02 Mass Daily /?6'ewY/.Total Daily Emissions
If (Calc TDE is null)
Rpt Period C02 Mass Calculated Accumulator Array for the location = -1
else
If {Rpt Period C02 Mass Calculated Accumulator Array for the location >= 0)
Rpt Period C02 Mass Calculated Accumulator Array for the location = Rpt Period C02 Mass Calculated
Accumulator Array for the location + Calc TDE
If (Current C02 Mass Daily /?6'cmy/. To t a 1D a i ly E m i s s i o n s >= 0)
Environmental Protection Agency
Page 102 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
If (Calc TDE is not null)
Tolerance = Lookup Tolerance from Cross-Check Table "Hourly Emissions Tolerances" where
Parameter = "C02M DAILY" AND
UOM = "TON"
if (A B S(Current C02 Mass Daily To ta 1Da i ly E missions - Calc TDE) > Tolerance)
return result A
else
return result C
else
Rpt Period C02 Mass Reported Accumulator Array for the location = -1
return result B
Results:
Result
A
Response
The [fieldname] reported in the Daily Emissions record for [param] is inconsistent with
the recalculated value.
The [fieldname] reported in the Daily Emissions record for [param] is invalid. The
value must be greater than or equal to 0.
The TotalDailyEmissions in the Daily Emissions record for [param] could not be
recalculated due to other errors listed in this report.
Severity
Critical Error Level 1
B
Critical Error Level 1
C
Informational Message
Usage:
1 Process/Category: Emissions Data Evaluation Report C02 Daily Emissions
Environmental Protection Agency
Page 103 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: DAILY-3
Check Name: Check Adjusted Daily Emissions Value
Related Former Checks:
Applicability:
Description:
Specifications:
if (Current C02 Mass Daily Record is not null),
if (Current C02 Mass 7?«»£w
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
DAILY-4
Check Name:
Check Sorbent Related Emissions
Related Former Checks:
Applicability:
Description:
Specifications:
if (Current C02 Mass Daily Record is not null),
if (Current C02 Mass Daily SorbcntRc 1 atcdIVIassEmissions is not null AND is less than 0),
return result A
Results:
Result
A
Response
The [fieldname] reported in the Daily Emissions record for [param] is invalid. The
value must be greater than or equal to 0.
Severity
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report C02 Daily Emissions
Environmental Protection Agency
Page 105 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
DAILY-5
Check Name:
Validate Presence of Adjusted Daily Emissions
Related Former Checks:
Applicability:
Description:
Specifications:
if (Current C02 Mass Daily Record) is not null
if (Current C02 Mass 7?«»£w
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
DAILY-6
Check Name:
Validate Presence of Sorbent Related Emissions
Related Former Checks:
Applicability:
Description:
Specifications:
if (Current C02 Mass Daily Record) is not null
if (Current C02 Mass Daily /?6'ewY/.SorbcntRclatcdIVIassEmissions is not null),
Missing C02M Formula = null
Locate a Monitor Formula record for the location and hour where the ParameterCode is equal to 'C02M" and the
FormulaCode is equal to "G-5" or "G-6".
If not found,
Set Missing C02MFormula to "G-5 or G-6"
Locate a Monitor Formula record for the location and hour where the ParameterCode is equal to 'C02M" and the
FormulaCode is equal to "G-8".
If not found,
Append "G-8" to Missing C02MFormula.
If {Missing C02M Formula is not null)
return result A.
Results:
Result
A
You reported SorbentRelatedMassEmissions in the Daily Emissions record for C02M, Critical Error Level 1
but you did not report [code] formula(s) in your monitoring plan.
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report C02 Daily Emissions
Environmental Protection Agency
Page 107 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
DAILY-7
Check Name:
Check Unadjusted Daily Emissions Value
Related Former Checks:
Applicability:
Description:
Validation Tables:
Hourly Emissions Tolerances (Cross Check Table)
Specifications:
Set Calc C02 Unadj to null.
if (Current C02 Mass Daily Record is not null)
if (Calc Total Carbon Burned is greater than 0)
Calculate Calc C02 Unadj = Calc Total Carbon Burned * 44 / 24,000, and round the result to 1 decimal place.
if (Current C02 Mass Daily nadj ustcdDailv Emissions is null OR is less than 0)
return result A
else if (Current CO2 Mass Daily nadj ustcdDailv Emissions >= 0)
Tolerance = Lookup Tolerance from Cross-Check Table "Hourly Emissions Tolerances" where
Parameter = "C02M DAILY" AND
UOM = "TON"
if (ABS(Current C02 Mass Daily RecordUnadjustcdDai ly Em iss io lis - Calc C02 Unadj) > Tolerance)
return result B
else if (Current C()2 Mass Daily /?6'ewY/.UnadjustcdDailyEmissions is null)
If (Legacy Data Evaluation == false)
return result A.
else if (Current C02 Mass Daily /?6'ew
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
DAILY-8
Check Name:
Check Fuel in Daily Fuel Record
Related Former Checks:
Applicability:
Description:
Specifications:
Locate UnitFuel record for the location and day
where FuelCd = Current Daily Fuel Record.UnitFuelCd
If not found,
return result A
Results:
Result Response Severity
A You did not report an active Unit Fuel record for FuelCode [fueled] in your monitoring Critical Error Level 1
plan.
Usage:
1 Process/Category: Emissions Data Evaluation Report C02 Daily Emissions Fuel
Environmental Protection Agency
Page 109 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
DAILY-9
Check Name:
Check Daily Fuel Feed
Related Former Checks:
Applicability:
Description:
Specifications:
if {CurrentDaily Fuel Record .Di\W\ FuelFeed is null)
return result A.
else if {CurrentDaily Fuel Record. Daily Flie 1 Fccd is less than or equal to 0)
return result A.
Results:
Result
A
The [fieldname] reported in the Daily Fuel record for [key] is missing or invalid. The Critical Error Level 1
value must be greater than 0.
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report C02 Daily Emissions Fuel
Environmental Protection Agency
Page 110 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
DAILY-10
Check Name:
Check Carbon Content Used
Related Former Checks:
Applicability:
Description:
Specifications:
if {Current Daily Fuel Record. Carbo nCo ntc ntU scd is null)
return result A.
else if {Current Daily Fuel Record. C a rb o n C o lit c n t U s cd is less than or equal to 0 or greater than 100)
return result A.
Results:
Result
A
The CarbonContentUsed in the Daily Fuel record for [key] is invalid. The value must Critical Error Level 1
be greater than 0 and less than or equal to 100.
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report C02 Daily Emissions Fuel
Environmental Protection Agency
Page 111 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: DAILY-11
Check Name: Check Fuel Carbon Burned
Related Former Checks:
Applicability:
Description:
Validation Tables:
Hourly Emissions Tolerances (Cross Check Table)
Specifications:
Calc Fuel Carbon Burned = null
if {Current Daily Fuel Record. Dai 1 y Flie 1 Feed is greater than 0 and Current Daily Fuel Carbo nCo ntc ntU scd is greater than 0 and
less than or equal to 100)
Calculate Calc Fuel Carbon Burned = Current Daily Fuel Record. Dai ly Flie 1 Feed * Current Daily Fuel
Record. Carbo nCo ntc ntU scd /100, and round the result to 1 decimal place.
If Calc Total Carbon Burned is greater than or equal to 0,
Add Calc Fuel Carbon Burned to Calc Total Carbon Burned.
else
Set Calc Total Carbon Burned to -1.
if {Current Daily Fuel FuclCarbonBurncd is null)
return result A.
else if {Current Daily Fuel Record .Fuel C a rb o n B u rnc d is less than or equal to 0)
return result A.
else if {Calc Fuel Carbon Burned is not null ANDCurrent Daily Fuel Record .Fuel C a rb o n B u rncd <> Calc Fuel Carbon Burned)
Tolerance = Lookup Tolerance from Cross-Check Table "Hourly Emissions Tolerances" where
Parameter = "CARBON" AND
UOM = "LB"
if (A B S( Current Daily Fuel Record .Fuel C a rb o n B u rnc d - Calc Fuel Carbon Burned ) > Tolerance)
return result B.
Results:
Result Response Severity
A The [fieldname] reported in the Daily Fuel record for [key] is missing or invalid. The Critical Error Level 1
value must be greater than 0.
B The [fieldname] in the Daily Fuel record for [key] is inconsistent with the recalculated Critical Error Level 1
value.
Usage:
1 Process/Category: Emissions Data Evaluation Report C02 Daily Emissions Fuel
Environmental Protection Agency
Page 112 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: DAILY-12
Check Name: Intialize Daily Emissions
Related Former Checks:
Applicability:
Description:
Specifications:
Set Calc Total Carbon Burned to 0.
Daily Op Time Accumulator Array for the location = 0.
Results:
Result Response
Usage:
1 Process/Category: Emissions Data Evaluation Report
Severity
C02 Daily Emissions Initialization
Environmental Protection Agency
Page 113 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
DAILY-13
Check Name:
Check Total Carbon Burned
Related Former Checks:
Applicability:
Description:
Validation Tables:
Hourly Emissions Tolerances (Cross Check Table)
Specifications:
Set Calculate C02M TDE to true.
if (Current C02 Mass Daily Record. Tota 1 Ca rbo nBurued is null)
if (Calc Total Carbon Burned is not equal to 0)
else if (Current C()2 Mass Daily Record.ToVdlCarbonBumcd is less than 0)
return result B.
if (Calc Total Carbon Burned is greater than 0 AND Current C02 Mass Daily Record.Total Carbo nB urncd <> Calc Total Carbon
Tolerance = Lookup Tolerance from Cross-Check Table "Hourly Emissions Tolerances" where
Parameter = "CARBON" AND
UOM= "LB"
if (ABS {Current C02 Mass Daily Record. Total C a rb o n B u rnc d - Calc Total Carbon Burned ) > Tolerance)
return result C.
else if (Calc Total Carbon Burned == 0 )
Set Calc Total Carbon Burned to Current C02 Mass Daily Record. Total Ca rbo nB urncd.
return result A.
else
Burned)
Results:
Result
A
Response
You did not report TotalCarbonBurned in the Daily Emission record for C02M. You
must report this value if you report Daily Fuel records.
The [fieldname] reported in the Daily Emissions record for [param] is invalid. The
value must be greater than or equal to 0.
The [fieldname] reported in the Daily Emissions record for [param] is inconsistent with
the recalculated value.
Severity
Critical Error Level 1
B
Critical Error Level 1
C
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report C02 Daily Emissions
Environmental Protection Agency
Page 114 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Category:
Daily Interference Status
Environmental Protection Agency
Page 115 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
INTSTAT-1
Check Name:
Determine the Online Daily Interference Check
Related Former Checks:
Applicability:
Description:
Specifications:
Set OnlineDailylntRecord = null
Set OfflineDailylntRecord = null.
Set DailylntStatusResult = null
Locate the latest record in DailyIntCheckRecordsByLocationForQAStatus for the location:
a) Date/Hour is on or prior to the Current MHVRecord.Date/Hour
b) ComponentID is equal to the Current MH V Record. Co mpo ncnt ID AND
c) TestResultCd is not equal to "IGNORED" //Ignored indicates an offline test
if (Daily IntCheckRecords By Location ForOAStatus is found)
Set OnlineDailylntRecord = the found record in DailylntCheckRecordsByLocationForQAStatus.
If (On tin el) ailylntRecord TestResultCd = "PASSED")
If (the number of clock hours between the OnlineDailylntRecord.EndDate/Hour and the CurrentMHVRecord.Date/Hour
is less than 26)
Set DailylntStatusResult = "IC"
else if (On/inel)ailylntRecord.TcstRcsu 11Cd = "FAILED")
Set DailylntStatusResult = "OOC-Test Failed"
else if (On tin el) ailylntRecord. Tc s t R c s u 11C d = "ABORTED")
Set DailylntStatusResult = "OOC-Test Aborted"
Set DailylntStatusResult = "OOC-Test Has Critical Errors"
If {DailylntStatusResult is not equal to "IC")
Locate the latest record in DailyIntCheckRecordsByLocationForQAStatus for the location where:
a) Date/Hour is on or prior to the Current MHV Record. Date/Hour
b) Date/Hour/Min is after the ()nI'meDailylntRecord. EndDatc/Hour/Mi n
c) The ComponentID is equal to the CurrentMHVRecord.ComponentID AND
d) TestResultCd is equal to "IGNORED"
if (DailylntCheckRecordsByLocationForQAStatus is found
else
Set OfflineDailylntRecord = the found record in DailyIntCheckRecordsByLocationForQAStatus.
If (DailylntStatusResult is not null)
Set DailylntStatusResult = DailylntStatusResult &
Results:
Result
Response
Severity
Environmental Protection Agency
Page 116 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
Usage:
1 Process/Category: Emissions Data Evaluation Report Daily Interference Check Status Evaluation
Environmental Protection Agency
Page 117 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: INTSTAT-2
Check Name: Determine Daily Interference Status for No Prior Check
Related Former Checks:
Applicability:
Description:
Specifications:
If (DailylntStatusResult is null) and (OnlineDailylntRecord is null)
/ Determine whether check in previous quarter is possibly effective for current hour.
If (the number of clock hours between the First Day of Operation/First Hour of Operation and the
CurrentMHVRecord Date/Hour is less than 25)
Set DailylntStatusResult = "IC-Undetermined".
else
/ If a non operating hour exists within the first 24 hours after the first operating hour in the quarter, a grace period exists
for seven hours after the operating hour subsequent to the non operating hour.
Locate the latest record in HourlyOpData where:
a) Date/Hour is ON OR PRIOR to the 24th clock hour following the First Day of Operation/First Hour of Operation
b) OpTime is equal to zero.
if (HourlyOpData is found)
Locate the first record in HourlyOpData where:
a) Date/Hour is after the Date/Hour in the HourlyOpData record found above
b) Date/Hour is ON OR PRIOR to the CurentMHVRecord. Datc/Hour
c) OpTime is greater than zero.
if (HourlyOpData is found) and (the number of clock hours starting at HourlyOpData.Date/Rour and up to the
hour before CurrentMHVRecord.Date/Hour is greater than 7)
Set DailylntStatusResult = "OOC-No Prior Test".
else
Set DailylntStatusResult = "IC-Undetermined".
else
Set DailylntStatusResult = "OOC-No Prior Test".
If (DailylntStatusResult begins with "OOC")
Locate the record in DailylntCheckRecordsByLocationForQAStatus for the location where:
a) Date/Hour is on or prior to the Current MHVRecord.Date/Hour
b) the ComponentID is equal to the Current MHV Record.Compo nc lit ID AND
c) TestResultCd is equal to "IGNORED"
if (DailyIntCheckRecordsByLocationForQAStatus is found)
Set OfflineDailylntRecord = the found record in DailyIntCheckRecordsByLocationForQAStatus.
Set DailylntStatusResult = DailylntStatusResult &
Environmental Protection Agency
Page 118 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Daily Interference Check Status Evaluation
Environmental Protection Agency
Page 119 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
INTSTAT-3
Check Name:
Determine Expiration Status for Prior Daily Interference Check
Related Former Checks:
Applicability:
Description:
Specifications:
If (DailylntStatusResult is null)
/ If a non operating hour exists within the first 27 hours after the hour of the online Daily Interference Check, a grace period exists
for seven hours after the operating hour subsequent to the non operating hour.
Locate the latest record in HourlyOpData where:
a) DateHour is after the OnlineDailyCalRecord Date/Hour.
b) Date/Hour is ON OR PRIOR to the 27th hour after the OnlineDailyCalRecord Date/Hour.
c) OpTime is equal to zero.
if (HourlyOpData is found)
Locate the earliest record in HourlyOpData where:
a) Date/Hour is after the Date/Hour in the HourlyOpData record found above.
b) Date/Hour is on or before the CurrentMHVRecordDate/Row
c) OpTime is greater than zero.
if (HourlyOpData is found) and (the number of clock hours starting at HourlyOpData.Date/Rour and up to the hour before
CurrentMHVRecord.Date/Hour is greater than 7)
else
Set DailylntStatusResult = "OOC-Expired".
If (DailylntStatusResult begins with "OOC" and OfflineDailylntRecord is not null)
Set DailylntStatusResult = DailylntStatusResult &
Return DailylntStatusResult
Set DailylntStatusResult = "OOC-Expired".
else
Set DailylntStatusResult = "IC-Grace".
else
Return DailylntStatusResult
Environmental Protection Agency
Page 120 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
OOC-Expired
OOC-Expired*
OOC-No Prior
Test
OOC-No Prior
Test*
OOC-Test
Aborted
OOC-Test
Aborted*
OOC-Test Failed
OOC-Test
Failed*
OOC-Test Has
Critical Errors
OOC-Test Has
Critical Errors*
Response
The prior daily interference check for [compkey] completed on [date] expired.
The prior daily interference check for [compkey] completed on [date] expired. A daily
interference check completed on [invdate] was ignored because it was completed while
the unit was offline.
You did not report a prior daily interference check for [compkey] during the reporting
period. Any daily interference check that may have been completed in a prior reporting
period has expired.
You did not report a prior daily interference check for [compkey] during the reporting
period. Any daily interference check that may have been completed in a prior reporting
period has expired. A daily interference check completed on [invdate] was ignored
because it was completed while the unit was offline.
The prior daily interference check for [compkey] completed on [date] was aborted.
The prior daily interference check for [compkey] completed on [date] was aborted. An
daily interference check completed on [invdate] was ignored because it was performed
while the unit was offline.
The prior daily interference check for [compkey] completed on [date] failed.
The prior daily interference check for [compkey] completed on [date] failed. An daily
interference check completed on [invdate] was ignored because it was performed while
the unit was offline.
The prior daily interference check for [compkey] completed on [date] has critical errors.
The prior daily interference check for [compkey] completed on [date] has critical errors.
An daily interference check completed on [invdate] was ignored because it was
performed while the unit was offline.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1
Process/Category: Emissions Data Evaluation Report Daily Interference Check Status Evaluation
Environmental Protection Agency
Page 121 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Category:
Daily Test
Environmental Protection Agency
Page 122 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: EMTEST-1
Check Name: Daily Test Date Valid
Related Former Checks:
Applicability:
Description:
Specifications:
For the daily emission test:
Set EM Test Date Valid to true.
If Date is null,
set EM Test Date Valid to false, and return result A.
If Date is before 01/01/1993 or after the end of the Current Reporting Period,
set EM Test Date Valid to false, and return result B.
Results:
Result Response Severity
A You did not provide [fieldname], which is required for [key]. Fatal
B You reported a [Fieldname] cf [Date], which is outside the range of acceptable values Critical Error Level 1
for this date for [key].
Usage:
1 Process/Category: Emissions Data Evaluation Report Daily Calibration Test
2 Process/Category: Emissions Data Evaluation Report Miscellaneous Emission File Test
Environmental Protection Agency
Page 123 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: EMTEST-2
Check Name: Daily Test Hour Valid
Related Former Checks:
Applicability:
Description:
Specifications:
For the daily emission test:
Set EM Test Hour Valid to true.
If Hour is null,
Set EM Test Hour Valid to false, and return result A.
If Hour is not between 0 and 23,
Set EM Test Hour Valid to false, and return result B.
Results:
Result Response Severity
A You did not provide [fieldname], which is required for [key]. Fatal
B You reported a [Fieldname] cf [Hour], which is outside the range of acceptable values Critical Error Level 1
for this hour for [key].
Usage:
1 Process/Category: Emissions Data Evaluation Report Daily Calibration Test
2 Process/Category: Emissions Data Evaluation Report Miscellaneous Emission File Test
Environmental Protection Agency
Page 124 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
EMTEST-3
Check Name:
Daily Test Minute Valid
Related Former Checks:
Applicability:
Description:
Specifications:
For the daily emission test:
Set EM Test Minute Valid to true.
If Minute is null,
If (Legacy Data Evaluation == false)
set EM Test Minute Valid to false, and return result A.
Otherwise,
return result B.
If Minute is not between 0 and 59,
set EM Test Minute Valid to false, and return result C.
Results:
Result
A
B
Response
You did not provide [fieldname], which is required for [key].
You did not provide [fieldname] for [key]. This information will be required for
ECMPS submissions.
You reported a [Fieldname] cf [Minute] for [key], which is outside the range of
acceptable values.
Severity
Fatal
Informational Message
C
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Daily Calibration Test
2 Process/Category: Emissions Data Evaluation Report Miscellaneous Emission File Test
Environmental Protection Agency
Page 125 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
EMTEST-4
Check Name:
Daily Test System or Component Valid
Related Former Checks:
Applicability:
Description:
Specifications:
For the daily test:
If both the MonitoringSystemID and ComponentID are not null,
return result A.
If TestTypeCode is equal to "INTCHK",
If ComponentID is null,
return result B.
If the ComponentTypeCode of the associated component is not equal to "FLOW",
return result C.
If TestTypeCode is equal to "PEMSCAL",
If MonitoringSystemID is null,
return result D.
If the SystemTypeCode of the associated system is not equal to "NOXP",
return result E.
Results:
Result
A
Response
You have reported both a MonitoringSystemID and a ComponentID for [key]. This is
invalid.
You did not provide [fieldname], which is required for [key].
The ComponentTypeCode for [key] is not appropriate for this type of test.
You did not provide a MonitoringSystemID for [key], which is required for this test
type.
The SystemTypeCode of the system for [key] is not appropriate for this type of test.
Severity
Critical Error Level 1
B
C
D
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
E
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Daily Calibration Test
2 Process/Category: Emissions Data Evaluation Report Miscellaneous Emission File Test
Environmental Protection Agency
Page 126 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
EMTEST-5
Check Name:
Daily Test Span Scale Valid
Related Former Checks:
Applicability:
Description:
Specifications:
For the daily test:
If the SpanScaleCode is not null,
return result A.
Results:
Result Response Severity
A You reported [fieldname] for [key], which is not appropriate for this test type. Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Miscellaneous Emission File Test
Environmental Protection Agency
Page 127 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: EMTEST-6
Check Name: Daily Test Result Code Valid
Related Former Checks:
Applicability:
Description:
Specifications:
For the daily test:
Set EM Test Calc Result to null.
If TestResultCode is null,
return result A.
else if TestResultCode is not equal to "ABORTED", "PASSED", or "FAILED",
return result B.
else
Set EM Test Calc Result to TestResultCode.
if TestTypeCode is equal to "INTCHK" and EM Test Date Valid and EM Test Hour Valid and OpTime is equal to 0,
Set Ignored Daily Interference Tests to true.
Set EM Test Calc Result to "IGNORED".
Results:
Result Response Severity
A You did not provide [fieldname], which is required for [key]. Critical Error Level 1
B You reported the value [value], which is not in the list of valid values for this test type, Critical Error Level 1
in the field [fieldname] for [key].
Usage:
1 Process/Category: Emissions Data Evaluation Report Miscellaneous Emission File Test
Environmental Protection Agency
Page 128 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Category:
EM Weekly System Integrity Test
Environmental Protection Agency
Page 129 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
EMWSI-1
Check Name:
Check Hg Converter Indicator of the Component
Related Former Checks:
Applicability:
Description:
Specifications:
If (CurrentWeeklySystemlntegrityTest .HgConverterlndicator is NOT equal to 1)
Set Weekly TestSummary Valid to false,
return result A.
Results:
Result
A
Response
For [key] you reported a HgConverterlndicator that is not equal to I, which indicates
that a Weekly System Integrity Test is not necessary.
Severity
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Weekly System Integrity Test Evaluation
Environmental Protection Agency
Page 130 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
EMWSI-2
Check Name:
Check Gas Level
Related Former Checks:
Applicability:
Description:
Specifications:
For CurrentWeeklySystemlntegrifyTest
If (GasLevelCode is null)
Set Weekly TestSummary Valid to false,
return result A.
Else if (GasLevelCode is NOT in set (HIGH, MID, LOW, ZERO))
Set Weekly TestSummary Valid to false,
return result B.
Else if (GasLevelCode is NOT in set (HIGH, MID))
Set Weekly TestSummary Valid to false,
return result C.
Results:
Result
A
B
Response
You did not provide a [fieldname], which is required, for [key].
For [key] you reported a [levelcode] that is not in the list of valid [fieldname] for this
test type.
For [key], you reported an invalid Gas Level Code of [levelcode], for a [testype].
Severity
Critical Error Level 1
Critical Error Level 1
C
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Weekly System Integrity Test Evaluation
Environmental Protection Agency
Page 131 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
EMWSI-3
Check Name:
Check Weekly System Integrity Reference Value
Related Former Checks:
Applicability:
Description:
Specifications:
For CurrentWeeklySystemlntegrifyTest
Set InjectionReferenceValueValid to false.
If (ReferenceValue is null)
Set Weekly TestSummary Valid to false,
return result A.
Else if (Reference Value is NOT rounded to one decimal place)
Set Weekly TestSummary Valid to false,
return result B.
Else if (ReferenceValue is NOT greater than 0)
Set Weekly TestSummary Valid to false,
return result C.
Else
Set InjectionReferenceValueValid to true
Results:
Result
Response
You did not provide a [fieldname], which is required, for [key].
The [fieldname] value for [key] should be reported to one decimal place.
Your reported CEM Value and/or Reference Value for [key] is less than or equal to
zero.
Severity
A
B
C
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Weekly System Integrity Test Evaluation
Environmental Protection Agency
Page 132 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
EMWSI-4
Check Name:
Check Weekly System Integrity Measured Value
Related Former Checks:
Applicability:
Description:
Specifications:
For CurrentWeeklySystemlntegrifyTest
Set InjectionMeasuredValueValid to false.
If (MeasuredValue is null)
Set Weekly TestSummary Valid to false,
return result A.
Else if (MeasuredValue is NOT rounded to one decimal place)
Set Weekly TestSummary Valid to false,
return result B.
Else if (MeasuredValue is NOT greater than 0)
Set Weekly TestSummary Valid to false,
return result C.
Else
Set InjectionMeasuredValueValid to true
Results:
Result
Response
You did not provide a [fieldname], which is required, for [key].
The [fieldname] value for [key] should be reported to one decimal place.
Your reported CEM Value and/or Reference Value for [key] is less than or equal to
zero.
Severity
A
B
C
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Weekly System Integrity Test Evaluation
Environmental Protection Agency
Page 133 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
EMWSI-5
Check Name:
Calculate System Integrity Error and Alternate Performance Spec Indicator
Related Former Checks:
Applicability:
Description:
Specifications:
For CurrentWeeklySystemlntegrifyTest
Set CalculatedSystemlntegrityApsIndicator to null.
Set CalculatedSystemlntegrityError to null.
If (InjectionReferenceValueValid AND InjectionMeasuredValueValid)
Set PercentError to (100 * ABS(Reference Value - MeasuredValue) / Reference Value), rounded to 1 decimal place.
If (PercentError is less than or equal to 10)
Set CalculatedSystemlntegrityApsIndieator to 0.
Set CalculatedSystemlntegrityError to PercentError.
Set CalculatedWeeklyTestSummaryResult to "PASSED".
Else
Set AbsoluteError to ABS(ReferenceValue - MeasuredValue), rounded to 2 decimal places.
If {AbsoluteError is less than or equal to 0.8)
Set CalculatedSystemlntegrityApsIndicator to 1.
Set CalculatedSystemlntegrityError to AbsoluteError.
Set CalculatedWeeklyTestSummaryResult to "PASSAPS".
Else
Set CalculatedSystemlntegrityApsIndicator to 0.
Set CalculatedSystemlntegrityError to PercentError.
Set CalculatedWeeklyTestSummaryResult to "FAILED".
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Weekly System Integrity Test Evaluation
Environmental Protection Agency
Page 134 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
EMWSI-6
Check Name:
Check Weekly System Integrity Alternative Performance Spec
Related Former Checks:
Applicability:
Description:
Specifications:
For CurrentWeeklySystemlntegrifyTest
Set WeeklySystemlntegrityApsIsValid to false.
If (InjectionReferenceValueValid and InjectionMeasuredValueValid)
If (Apslndicator is null)
Set Weekly TestSummary Valid to false,
return result A.
Else if (Apslndicator is NOT equal to 0 OR 1)
Set Weekly TestSummary Valid to false,
return result B.
Else if (Apslndicator is NOT equal to CalculatedSystemlntegrityApslndicator)
Set Weekly TestSummary Valid to false,
return result C.
Else
Set WeeklySystemlntegrityApsIsValid to true.
Results:
Result
Response
You did not provide a [fieldname], which is required, for [key].
You did not report an APSIndicator of "0" or "1" for [key].
The APSIndicator reported for [key] is inconsistent with the APSIndicator recalculated
from the reported reference and measured values.
Severity
A
B
C
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Weekly System Integrity Test Evaluation
Environmental Protection Agency
Page 135 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
EMWSI-7
Check Name:
Check Weekly System Integrity Error
Related Former Checks:
Applicability:
Description:
Specifications:
For CurrentWeeklySystemlntegrifyTest
Set WeeklySystemlntegrityErrorlsValid to false.
If (InjectionReferenceValueValid and InjectionMeasuredValueValid)
If (SystemlntegrityError is null)
Set Weekly TestSummary Valid to false,
return result A.
Else if (WeeklySystemlntegrityApsIsValid)
If (SystemlntegrityError is NOT rounded to one decimal place)
Set Weekly TestSummary Valid to false,
return result B.
Else if (SystemlntegrityError is NOT equal to CalculatedSystemlntegrityError)
Set Weekly TestSummary Valid to false,
return result C.
Else
Set WeeklySystemlntegrityErrorlsValid to true.
Results:
Result
Response
You did not provide a [fieldname], which is required, for [key].
[fieldname] is not reported to one decimal place.
The [fieldname] value for [key] is inconsistent with the value of [value], recalculated
from the reported [testtype] records.
Severity
A
B
C
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Weekly System Integrity Test Evaluation
Environmental Protection Agency
Page 136 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
EMWSI-8
Check Name:
Check Weekly Test Summary Result Against Calculated Value
Related Former Checks:
Applicability:
Description:
Specifications:
If (CalculatedWeeklyTestSummaryResult is NOT null) and (CurrentWeekly TestSummary. TcstRcsu 11Codc is NOT equal to
CalculatedWeekly TestSummary Result)
Set CalculatedWeekly TestSummary Result to null.
Set Weekly TestSummary Valid to false,
return result A.
Results:
Result
A
Response
For [key], the [fieldname] is not consistent with the test result recalculated from the
reported records.
Severity
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Weekly System Integrity Test Evaluation
Environmental Protection Agency
Page 137 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
EMWSI-9
Check Name:
Update Weekly System Integrity Dictionary Component Entry
Related Former Checks:
Applicability:
Description:
Specifications:
If (WsiTestDictionary does NOT contain a key equal to CurrentWeeklySystemlntegrityTest.Componentld)
Add an entry to WsiTestDictionary for Cur rentWeeklySystem Integrity Test. Co mpo ne nt Id with the following fields:
a) MostRecentTestRecord
b) OperatingDateList initialized as an empty list.
For the WsiTestDictionary entry where the key is equal to Current Weekly Systemlntegrity Test.Compomntld:
Set MostRecentTestRecord to CurrentWeeklySystemlntegrityTest.
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Weekly System Integrity Test Evaluation
Environmental Protection Agency
Page 138 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
EMWSI-10
Check Name:
Update Weekly System Integrity Dictionary Operating Date Information
Related Former Checks:
Applicability:
Description:
Specifications:
If (CurrentOperatingTime is greater than 0)
For each entry in WsiTestDictionary:
If (MostRecentTestRecord is NOT null) AND (MostRecentTestRecord .TestDateHour is equal to CurrentDateHour)
Set OperatingDateList to an empty list.
If (MostRecentTestRecord is NOT null) AND (MostRecentTestRecord.TestDate is prior to or CurrentDateHour) AND
(OperatingDateList does NOT contain CurrentOperatingDate)
Add CurrentOperatingDate to OperatingDateList
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Weekly System Integrity Test Operating Dates
Environmental Protection Agency
Page 139 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Category:
EM Weekly Test Summary
Environmental Protection Agency
Page 140 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: EMWTS-1
Check Name: Initialize Parameters
Related Former Checks:
Applicability:
Description:
Specifications:
Set Weekly TestSummary Valid to true.
Set CalculatedWeeklyTestSummaryResult to null.
Results:
Result Response
Usage:
1 Process/Category: Emissions Data Evaluation Report
Severity
Weekly System Integrity Test Evaluation
Environmental Protection Agency
Page 141 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: EMWTS-2
Check Name: Check Weekly Test Type
Related Former Checks:
Applicability:
Description:
Specifications:
For CurrentWeeklyTestSummary
If (TestTypeCode is not equal to "HGSI1"),
Set Weekly TestSummary Valid to false,
return result A.
Results:
Result Response Severity
A You reported a [testtype] in [key] that is not a valid TestTypeCode for a weekly test. Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Weekly System Integrity Test Evaluation
Environmental Protection Agency
Page 142 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: EMWTS-3
Check Name: Check Weekly Test System
Related Former Checks:
Applicability:
Description:
Specifications:
For CurrentWeeklyTestSummary
If (TestTypeCode is equal to "HGSI1"),
If (Systemld is NOT null),
Set Weekly TestSummary Valid to false,
return result A.
Results:
Result Response Severity
A You reported a MonitoringSystemID for [key], which is not valid for a [testtype]. Only Critical Error Level 1
a ComponentID is reported for a [testtype].
Usage:
1 Process/Category: Emissions Data Evaluation Report Weekly System Integrity Test Evaluation
Environmental Protection Agency
Page 143 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
EMWTS-4
Check Name:
Check Weekly Test Component
Related Former Checks:
Applicability:
Description:
Specifications:
For CurrentWeeklyTestSummary
If (TestTypeCode is equal to "HGSI1")
If (Componentld is null)
Set Weekly TestSummary Valid to false,
return result A.
Else if (ComponentTypeCode is NOT equal to "HG")
Set Weekly TestSummary Valid to false,
return result B.
Results:
Result
A
B
Response
You did not provide [fieldname], which is required for [key].
The ComponentTypeCode for [key] is not appropriate for this type of test.
Severity
Critical Error Level 1
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Weekly System Integrity Test Evaluation
Environmental Protection Agency
Page 144 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: EMWTS-5
Check Name: Check Weekly Test Date
Related Former Checks:
Applicability:
Description:
Specifications:
For CurrentWeeklyTestSummary
Set TestDateValid to false.
If (TestDate is null)
Set Weekly TestSummary Valid to false,
return result A.
Else if (TestDate is before 01/01/1993) OR (TestDate is after CurrentReportingPeriodEndHour)
Set Weekly TestSummary Valid to false,
return result B.
Else
Set TestDateValid to true.
Results:
Result Response Severity
A You did not provide a [fieldname], which is required, for [key]. Critical Error Level 1
B You reported a [Fieldname] cf [Date], which is outside the range of acceptable values Critical Error Level 1
for this date for [key].
Usage:
1 Process/Category: Emissions Data Evaluation Report Weekly System Integrity Test Evaluation
Environmental Protection Agency
Page 145 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: EMWTS-6
Check Name: Check Weekly Test Hour
Related Former Checks:
Applicability:
Description:
Specifications:
For CurrentWeeklyTestSummary
Set TestHourValid to false.
If (TestHour is null)
Set Weekly TestSummary Valid to false,
return result A.
Else if (TestHour is NOT between 0 and 23)
Set Weekly TestSummary Valid to false,
return result B.
Else
Set TestHourValid to TestDateValid.
Results:
Result Response Severity
A You did not provide [fieldname], which is required for [key]. Critical Error Level 1
B You reported a [Fieldname] cf [Hour], which is outside the range of acceptable values Critical Error Level 1
for this hour for [key].
Usage:
1 Process/Category: Emissions Data Evaluation Report Weekly System Integrity Test Evaluation
Environmental Protection Agency
Page 146 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: EMWTS-7
Check Name: Check Weekly Test Minute
Related Former Checks:
Applicability:
Description:
Specifications:
For CurrentWeeklyTestSummary
Set TestDateTimeValid to false.
If (TestMinute is null)
Set Weekly TestSummary Valid to false,
return result A.
Else if (TestMinute is NOT between 0 and 59)
Set Weekly TestSummary Valid to false,
return result B.
Else if (TestHour Valid)
Set TestDateTimeValid to true.
Results:
Result Response Severity
A You did not provide a [fieldname], which is required, for [key]. Critical Error Level 1
B You reported a [Fieldname] cf [Minute] for [key], which is outside the range of Critical Error Level 1
acceptable values.
Usage:
1 Process/Category: Emissions Data Evaluation Report Weekly System Integrity Test Evaluation
Environmental Protection Agency
Page 147 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
EMWTS-8
Check Name:
Check Weekly Test Span Scale
Related Former Checks:
Applicability:
Description:
Specifications:
For CurrentWeeklyTestSummary
If (SpanScaleCode is null)
Set Weekly TestSummary Valid to false,
return result A.
Else if (SpanScaleCode is NOT in set (H, M, L))
Set Weekly TestSummary Valid to false,
return result B.
Else if (TestTypeCode is equal to "HGSI1")
If (SpanScaleCode is NOT equal to "H")
Set Weekly TestSummary Valid to false,
return result C.
Results:
Result
A
B
Response
You did not provide a [fieldname], which is required, for [key].
For [key], you reported a SpanScaleCode that in not an appropriate code for a
[testtype].
For [key], you reported a SpanScaleCode that in not an appropriate code for a
[testtype].
Severity
Critical Error Level 1
Critical Error Level 1
C
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Weekly System Integrity Test Evaluation
Environmental Protection Agency
Page 148 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
EMWTS-9
Check Name:
Check Weekly Test Result
Related Former Checks:
Applicability:
Description:
Specifications:
For CurrentWeeklyTestSummary
Set TestResultValid = false.
If (TestResultCode is null)
Set Weekly TestSummary Valid to false,
return result A.
Else if (TestResultCode is not in TestResultCodeList)
Set Weekly TestSummary Valid to false,
return result B.
Else if (TestTypeCode is equal to "HGSI1")
ff (TestResultCode is NOT in set (PASSED, PASSAPS, FAILED))
Set Weekly TestSummary Valid to false,
return result C.
Else
Set TestResultValid = true.
Else
Set TestResultValid = true.
Results:
Result
A
B
Response
You did not provide a [fieldname], which is required, for [key].
You reported the value [value], which is not in the list of valid values for this test type,
in the field [fieldname] for [key].
You reported the value [value], which is not in the list of valid values for this test type,
in the field [fieldname] for [key].
Severity
Critical Error Level 1
Critical Error Level 1
C
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Weekly System Integrity Test Evaluation
Environmental Protection Agency
Page 149 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Category:
Flow-to-Load Status
Environmental Protection Agency
Page 150 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: F2LSTAT-1
Check Name: Determine Most Recent Flow-to-Load QA Operating Quarter
Related Former Checks:
Applicability:
Description:
Specifications:
Set F2LStatusPriorTestRequiredQuarter = null.
Set F2LStatusPriorTestRequiredQuarterMissingOpData = null.
If F2LStatusSystemResuItDictionary does not contain lookup value for CurrentMh vRecord.SystemID
Locate the most recent record in RataTestRecordsByLocationForQaStatus where the SystemID is equal to
Cur rentMh v Record. Sy stc m ID. EndDateHour is before the CurrentReportingPeriod, and TestResultCode is not equal to
"INVALID"
If found,
For each quarter before CurrentReportingPeriod beginning with the quarter immediately before CurrentReportingPeriod
and going back to later of the quarter of the located RataTestRecordsByLocationForQaStatus and the quarter of the
Earliest Location Report Date
If AnnualReportingRequirement equals true, or the quarter being checked is 2 or 3
If AnnualReportingRequirement equals true, or the quarter being checked is 3
Locate the record in OperatingSuppDataRecordsByLocation where OpTypeCode is equal to
"OPHOURS", FuelCode is null, and reporting period equals the quarter being checked
Else
Locate the record in OperatingSuppDataRecordsBy Location where OpTypeCode is equal to
"OSHOURS", FuelCode is null, and reporting period equals the quarter being checked
If OperatingSuppDataRecordsByLocation record is found
If F2LStatusPriorTestRequiredQuarter does not equal -1
If ()peratingSuppl)ataRecordsIiyLocation.OpVa 1 lie >= 168
Locate a record in F2LCheckRecordsForQaStatus where SystemID is equal to
CurrentMhvRecord. SystemID, the quarter is equal to the quarter being checked,
and TestResultCode is equal to "EXC168H" or "FEW168H"
If not found
Set F2LStatusPriorTestRequiredQuarter. Year = The year value of the
quarter being checked.
Set F2LStatusPriorTestRequiredQuarter. Quarter = The quartervalue of
the quarter being checked.
Exit the check.
Else
Set F2LStatusPriorTestRequiredQuarter = -1.
Append "[YEAR]Q[QTR]" to F2LStatusPriorTestRequiredQuarterMissingOpData (where
[YEAR] and [QTR are the year and number of the quarter being checked.
Environmental Protection Agency
Page 151 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Else
Set F2I.StatusPriorTestRequiredQuarter = -1.
Set F2LStatusPriorTestRequiredQuarterMissingOpData = "No Prior RATA"
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Flow-to-Load Status Evaluation
Environmental Protection Agency
Page 152 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
F2LSTAT-2
Check Name:
Locate Most Recent Flow-to-Load Check Prior to the Current Hour
Related Former Checks:
Applicability:
Description:
Specifications:
If F2LStatusSystemResu1tDietionary contains lookup value for CurrentMh vRecord. Sy stem ID
Set F2LStatusResult = F2LStatusSystemResu1tDietionary lookup value for CurrentMh vRecord. Sy stcmID.
Set CurrentFlowToLoadStatusCheck = F2LStatusSystemCheckDictionary lookup value for CurrentMh vRecord. Sy stem ID.
Set F2LStatusMissingOpDataInfo = F2lStatusSystemMissingOpDictionary lookup value for CurrentMhvRecord.SystemID.
Else
Set F2LStatusResult = null.
Set CurrentFlowToLoadStatusCheck = null.
Set F2LStatusMissingOpDataInfo = null.
Locate the most recent record in F2LCheckRecordsForQaStatus where SystemID is equal to CurrentMhvRecord. SystemID,
EndDate < CurrentReportingPeriodBeginDateHour, and TestResultCode is equal to "PASSED" or "FAILED"
If not found
Locate a record in MpLocationNonLoadBasedRecords where the location is the location in CurrentMhvRecord.
If found, and NonLoadBaselnd equals 1
Set F2LStatusResult = "IC-Exempt".
Else
Locate a record in TestExtensionExemptionRecords where the SystemID is equal to the
CurrentMhvRecord.SystemID, the ExtensionExemptionCode is equal to "F2LEXP", and the reporting period is
the period before the current reporting period.
If found
Set F2LStatusResuh = "IC-Exempt".
Else
Locate the most recent record in RataTestRecordsByLocationForQaStatus where the SystemID is equal
to CurrentMhvRecord.SystemID, EndDate < CurrentReportingPeriodBeginDateHour, and
TestResultCode is not equal to "INVALID"
If not found
Set F2LStatusResult = "IC-No Prior RATA".
Else if F2LStatusPriorTestRequiredQuarter is equal to -1
Set F2LStatusResuh = 'Missing Op Data".
Set F2LStatusMissingOpDataInfo = F2LStatusPriotTestRequiredQuarterMissingOpData.
Else if F2LStatusPriorTestRequiredQuarter is null or before the quarter of the located
Rata TestRecordsByLocationForQaStatus record
Environmental Protection Agency
Page 153 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Set F2LStatusResu1t = "IC".
Else if the quarter of the located RataTestRecordsByLocationForQaStatus record is the quarter before
CurrentReportingPeriod, the TestReasonCode equals "INITIAL" or "RECERT" and TestResultCode
equals "PASSED"
Set F2LStatusResult = "IC".
Else if CurrentMhvRecord.SystemDQsigmtionCode is equal to "RB"
Set F2LStatusResult = "Undetermined-No Prior Check reported for Redundant Backup Monitor".
Else
Set F2LStatusResult = "OOC-Prior Check Missing".
Set CurrentFlowToLoadStatusCheck = the located F2LCheckRecordsForQaStatus record.
If the quarter of CurrentFlowToLoadStatusCheck is not the quarter before CurrentReportingPeriod
If F2LStatusPriorTestRequiredQuarter is equal to -1
Set F2LStatusResuh = 'Missing Op Data".
Set F2LStatusMissingOpDataInfo = F2LStatusPriotTestRequiredQuarterMissingOpData.
Else if F2LStatusPriorTestRequiredQuarter is not null, and is after the quarter of
CurrentFlowToLoadStatusCheck
if CurrentMhvRecord.SyslcmDcsigmlionCodc is equal to "RB"
Set F2LStatusResult = "Undetermined-No Prior Check reported for Redundant Backup Monitor".
Else
Else
Set F2LStatusResult = "OOC-Prior Check Missing".
Else if CurrentFlowToLoadStatusCheck.TesiResultCode = "PASSED'
Set F2LStatusResult = "IC".
Else
If CurrentFlowToLoadStatusCheck.TesiResultCode = "PASSED'
Set F2LStatusResult = "IC".
Set F2LStatusSystemResultDictionary lookup value for CurrentMh vRecord. Sy stem ID = F2LStatusResult.
Set F2LStatusSystemCheckDictionary lookup value for CurrentMhvRecord.SystemID = CurrentFlowToLoadStatusCheck.
Set F2lStatusSystemMissingOpDictionary lookup value for CurrentMhvRecord .SystemID = F2LStatusMissingOpDataInfo.
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Flow-to-Load Status Evaluation
Environmental Protection Agency
Page 154 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
F2LSTAT-3
Check Name:
Locate Intervening RATA
Related Former Checks:
Applicability:
Description:
Specifications:
Set F2LStatusInterveningRata = null.
If F2LStatusResult is null
Locate the most recent record in RataTestRecordsByLocationForQaStatus where the SystemID is equal to
CurrentMh vRecord. Sy stem ID. EndDateHour is after CurrentFlowToLoadStatusCheck .EndDateHour and before
CwmjM/MAvTtecon/.BeginDate/BeginHour, and TestResultCode is not equal to "INVALID"
If found,
Set F2LStatusResult = "IC-Subsequent RATA Performed".
Set F2LStatusInterveningRata = The located record in RataTestRecordsByLocationForQaStatus.
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Flow-to-Load Status Evaluation
Environmental Protection Agency
Page 155 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: F2LSTAT-4
Check Name: Locate Most Recent QA Cert Event
Related Former Checks:
Applicability:
Description:
Validation Tables:
[Test Type to Required Test Code] (Cross Check Table)
Specifications:
Set F2LStatusQaCertEvent = null.
Set F2L Status Event Requires RA TA = false.
Set F2L Status Event Requires Abbreviated Check = false.
If F2LStatusResuh is null
Locate the most recent record in QACertificationEventRecords where the SystemID is equal to CurrentMhvRecord.SystemID.
QaCertEventCode is equal to "312", QaCertEventDateHour is on or after CurrentFlowToLoadStatusCheck.EndDdicHour. and
QaCertEventDateHour is on or before CurrentMh vRecord. Begi nDatc/BcginHour.
If found,
Set F2LStatusQaCertEvent = The located record in QACertificationEventRecords.
Locate a record in Cross-Check Table "Test Type to Required Test Code" where TestTypeCode begins with "RATA" and
RequireTestCode equals F2LStatusOaCertE vent.RcqulrcdJcsiCodc.
If found,
F2L Status Event Requires RA TA = true.
Locate a record in Cross-Check Table "Test Type to Required Test Code" where TestTypeCode is equal to "AF2LCHK"
and RequireTestCode equals F2LStatusQaCertEvent.RequirQdTestCode.
If found,
F2L Status Event Requires Abbreviated Check = true.
If F2/..SY«?M.v(>rtC.'6'/-?£'v'6'rt?.LastTcstCoinplctcdDatcHour is on or before Cu rrentMh v Record. B eg i n Da tc/B eg i n H ou r
If F2L Status Event Requires Abbreviated Check is equal to true,
Set F2LStatusResult = "IC-Subsequent Abbreviated Flow-to-Load Check Passed".
If F2LStatusResult is null,
If F2LStatusQaCertEvent = null, or F2/..SY«?M.v(>c/C.'6'/*?£'v'6'rt?.ConditionalDataBcginDatcHour is after
CurrentMh v Record. B c g i n D a t c/ B eg i n H o u r.
Locate records in RataTestRecordsByLocationForQaStatus where the SystemID is null or is equal to
Cu rrentMh v Record .SystemID. EndDateHour is after CurrentFlowToLoadStatusCheck. EndDateHour and before
CurrentMhBeginDate/BeginHour. and TestResultCode is equal to "INVALID".
If found
Set F2LStatusResult = "OOC-Check Failed - Invalid RATA Ignored".
Environmental Protection Agency
Page 156 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Else
Set F2LStatusResult = "OOC-Check Failed".
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Flow-to-Load Status Evaluation
Environmental Protection Agency
Page 157 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
F2LSTAT-5
Check Name:
Locate Earliest Valid Required Test
Related Former Checks:
Applicability:
Description:
Specifications:
Set F2lStatusEarliestValidRequiredTest = null.
If F2LStatusResult is null
If F2L Status Event Requires RA TA is true,
Locate earliest record in RataTestRecordsByLocationForQaStatus where the SystemID is equal to
CurrentMh vRecord. Sy stem ID. EndDateHour is after CwrreMfMAvTtecon/.BeginDate/BeginHour, and TestResultCode is
not equal to "INVALID".
If found,
Set F2LStatusEarliestValidRequiredTest = The located record in RataTestRecordsByLocationForQaStatus .
If F2LStatusEarliestValidRequiredTest .TestResultCode is equal to "FAILED"
Locate records in RataTestRecordsHy Location ForOaStatus w here the SystemID is equal to
CurrentMh vRecord. Sy stcml D. EndDateHour is after F2LStatusQaCertEvent.QaCer\E\en\DateRow and
before F2LSt(itusEarliestValidRequiredTest.EndDMcHour. and TestResultCode is equal to "INVALID".
If found
Set F2LStatusResu1t = "OOC-Recertification RATA Failed - Invalid RATA Ignored".
Else
Set F2LStatusResu1t = "OOC-Recertification RATA Failed".
Else if F2L Status Event Requires Abbreviated Check is false,
Set F2LStatusResult = "OOC-Invalid Cert Event".
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Flow-to-Load Status Evaluation
Environmental Protection Agency
Page 158 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: F2LSTAT-6
Check Name: Determine Event Conditional Status and Final Status
Related Former Checks:
Applicability:
Description:
Specifications:
If F2LStatusResuh is null
Set F2L Status Missing Op Data Info = null.
If F2L Status Event Requires RA TA is true,
Set OperatingHourLimit = 720
else
Set OperatingHourLimit = 168
If (the quarter of the F2LStatusOaCertEvent.Con&\\\om\\BcgmDi\\c is equal to the quarter of the CurrentMhvRecord.Date/Hour)
Count the number of HourlyOpData records for the location where OpTime is greater than 0 and Date/Hour is ON OR
AFTER the F2LS,fafMsgaC,ert£'vewf.ConditionalBeginDate/Hour and ON OR BEFORE CurrentMhvRecord Date/Hour,
If the number > OperatingHourLimit,
Set F2LStatusResuh = "OOC-Conditional Period Expired".
else
Set F2LStatusResuh = "IC-Conditional".
else
if (F2LStatusOaCertEventMinOpHoursPrior()ui\r{cr is null)
Set F2LStatusOaCertEventM'mO\Mov\xsPf\oxQv\c\r\cx = 0
Set F2 LStatusOaCertEvent MnxOpHomsPnoKJirMcr = 0
for each quarter beginning with the quarter of the F2 LStatusOaCertEvent.Cond\Uom\Rcg\nDn{c and continuing
through the quarter BEFORE the CurrentMhvRecord Date/Hour :
if (EarliestLocationReportDate <= the last day of the quarter being checked)
if {Annual Reporting Requirement == false AND the quarter being checked == 2)
Locate the record in OperatingSuppDataRecordsbyLocation where the OpTypeCode is
equal to "OSHOURS" and the reporting period is equal to the quarter being checked.
else
Locate the record in OperatingSuppDataRecordsby Location where the OpTypeCode is
equal to "OPHOURS", FuelCode is null, and the reporting period is equal to the quarter
being checked.
if (OperatingSuppDataRecordsbyLocation is not found)
Environmental Protection Agency
Page 159 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Set F2LStatusOaCertEventM\nO\Mo\ixsVnoxQmx\c.x = -1
Append " [YEAR] Q[QTR]" to F2L Status Missing Op Data Info (where [YEAR] is the
year of the quarter being checked and [QTR] is the number of the quarter being checked.)
exit for.
else
If the quarter being checked is the quarter of the
F2LStatusOaCertEvent.Con&\\\om\\Bcg\nDi\\c
If ((iperatingSuppDataRecordsbyLocation. O p Va 1 lie MINUS the number of
calendar hours in the quarter being checked that are PRIOR to the
F2/..SY«?M.v(>c/C.'67*?£'v'6'rt?.CoiiditioiialBcgiiiDatc/Hour > 0)
Set F2/..SY«?M.v(>c/C.'67*?£'v'6'rt?.IVIiiiOpHoursPriorQuartcr =
OperatingSuppDataRecordsby Location.OpVn\uc MINUS the number
of calendar hours in the quarter being checked that are PRIOR to the
F2LStatusQaCertEvent.Conditiom1BeginDate/Ylow
If ((iperatingSuppDataRecordsbyL ocation. O p Va 1 lie is less than the number of
calendar hours in the quarter begin checked that are ON OR AFTER the
F2/..SY?M.v(>c/C.'67*?£'v'677?.IVIa\OpHoursPriorQuartcr =
OperatingSuppDataRecordsby Location.OpVMuc.
else
Set F2 LStatusOaCertEvent.MaxOpHoursPviorQwMcr = the number of
calendar hours in the quarter being checked that are ON OR AFTER the
F2 LStatusOaCertE vent.CondiUom\\Bcg'u\D'Mc/Hour.
else
Set F2 LStatusOaCertE vent. IVT i nO p H o u rs P ri o rQ ua rtc r =
F2 LStatusOaCertEvent.MlnOpHoursPvlorQunvlcr +
(iperatingSuppDataRecordsbyL ocation. O p Va 1 lie.
Set F2 LStatusOaCertE vent. IVT a\0 p H o u rs PriorQuarter =
F2 LStatusOaCertEvent.MaxOpHoursPviorQwMcr +
(iperatingSuppDataRecordsbyL ocation. O p Va 1 lie.
If (F2 LStatusOaCertE vent. IVT i nO p H o u rs P ri o rQ ua rtc r == -1)
set F2LStatusResult to "Missing Op Data"
Else if (F2/..SY«?M.v(>c/C.'67*?£'v'677?.IVIinOpHoursPriorQuartcr > OperatingHourLimit)
If F2L Status Event Requires RA TA is true,
Locate records in RataTestRecordsByLocationForQaStatus where the SystemID is equal to
CurrentMh vRecord. Sy stcmID. EndDateHour is on or after
F2/..SY«?M.v(>c/C.'67*?£'v'677?.ConditionalDataBcginDatc/ConditionalDataBcginHour and on or before
CurrentMh vRecord. B c g i n D a t c/B c g i n H o u r. and TestResultCode is equal to "INVALID".
If found,
Environmental Protection Agency
Page 160 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Set F2LStatusResult = "OOC-Conditional Period Expired-Invalid RATA Ignored".
Else
Set F2LStatusResuh = "OOC-Conditional Period Expired".
Else
Set F2LStatusResuh = "OOC-Conditional Period Expired".
Else if (Rpt Period Op Hours Accumulator Array for the location == -1)
Set F2LStatusResult = "Invalid Op Data".
Else if (F2LStatusQaCertEventMmO\fiiomsPnoxQ\m{sx + Rpt Period Op Hours Accumulator Array for the Location >
OperatingHourLimit)
If F2L Status Event Requires RA TA is true,
Locate records in RataTestRecordsByLocationForQaStatus where the SystemID is equal to
CurrentMh v Record. Sy stcmID. EndDateHour is on or after
/r2/,lSY«fH.v(7«Ce/,f£Vewf.ConditionalDataBcginDatc/ConditionalDataBcginHour and on or before
CurrentMhvRecord.BcginDatc/BcginHour. and TestResultCode is equal to "INVALID".
If found,
Set F2LStatusResuh = "OOC-Conditional Period Expired-Invalid RATA Ignored".
Else
Set F2LStatusResult = "OOC-Conditional Period Expired".
Else
Set F2LStatusResuh = "OOC-Conditional Period Expired".
Else if (F2LStatusOaCertEvent.Mi\xOpHoursPrior()ui\r{cr + Rpt Period Op Hours Accumulator Array for the Location >
OperatingHourLimit)
Set F2LStatusResult = "Undetermined-Conditional Data".
Else
Set F2LStatusResuh = "IC-Conditional".
If (FlowToLoadStatusResult does not begin with "IC")
Return result F2LStatusResult.
Environmental Protection Agency
Page 161 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
Invalid Op Data
Missing Op Data
OOC-Check
Failed - Invalid
RATA Ignored
OOC-Conditional
Period Expired
OOC-Conditional
Period
Expired-Invalid
RATA Ignored
OOC-Invalid
Cert Event
OOC-Prior
Check Missing
OOC-Recertificat
ion RATA Failed
OOC-Recertificat
ion RATA Failed
- Invalid RATA
Ignored
Undetermined-Co
nditional Data
U ndetermined-N
o Prior Check
reported for
Redundant
Backup Monitor
Response
The Flow-to-Load status for [SYSID] could not be determined, because the
OperatingTime in at least one Hourly Operating Data records was missing or invalid.
The Flow-to-Load status for [SYSID] could not be determined, because the Op Supp
Data record for OPHOURS, OSHOURS, or OPDAYS is missing for one or more
previous reporting periods. If you have submitted emissions data for prior quarters, you
should be able to synchronize these records to your Client Tool by logging on to the
EPA host.
The prior Flow-to-Load Check for SystemID [SYSID] has failed, a subsequent invalid
RATA with was ignored.
The conditional data period for QACertEventCode [code] QACertEventDate
[eventdate] for [SYSID] has expired.
The conditional data period for QACertEventCode [code] QACertEventDate
[eventdate] for SystemID [EVENTKEY] has expired. An invalid RATA was ignored.
You reported an invalid QA Certification Event record for QACertEventCode [code]
QACertEventDate [eventdate] for [SYSID],
One or more Flow-to-Load Checks is missing for prior quarters.
The subsequent recertification RATA for SystemID [SYSID] with TestNumber
[subtestnum] failed.
The subsequent recertification RATA for SystemID [SYSID] with TestNumber
[subtestnum] failed. An invalid RATA was ignored.
The software could not determine if the current hour was within the conditional data
period for QACertEventCode [code] QACertEventDate [eventdate] for SystemID
[eventkey].
The software could not determine if a Flow-to-Load check is required for the
Redundant Backup Flow Monitor.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Informational Message
Informational Message
Usage:
1
Process/Category: Emissions Data Evaluation Report ¦
¦ Flow-to-Load Status Evaluation
Environmental Protection Agency
Page 162 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Category:
Hourly Aggregation
Environmental Protection Agency
Page 163 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAGG-1
Check Name: Determine Start Quarter
Related Former Checks:
Applicability:
Description:
Specifications:
Set Start Quarter to null.
Set SO2 Start Quarter to null.
Set NOXR Start Quarter to null.
Set CO 2 Start Quarter to null.
Set Heat Input Start Quarter to null.
Set NOXStart Quarter to null.
Set Emissions Tolerance Deviators to null.
If (Quarter of the Current Reporting Period is greater than 1)
Locate the earliest Monitor Method for location where BeginDate is on or before the last day of the Current Reporting Period, and
EndDate is null or is on or after Jan 1 of the year of the Current Reporting Period.
If found,
If BeginDate is in a year prior to the current reporting period,
If {Annual Reporting Requirement == true)
Set Start Quarter to 1.
else
Set Start Quarter to 2.
else
Set Start Quarter to the quarter of the BeginDate.
Locate the earliest Monitor Method for location where ParameterCode = "S02" or "S02M", BeginDate is on or before the last day
of the Current Reporting Period, and EndDate is null or is on or after Jan 1 of the year of the Current Reporting Period.
If found,
If BeginDate is in a year prior to the current reporting period,
Set SO2 Start Quarter to 1.
else
Set SO2 Start Quarter to the quarter of the BeginDate.
If (IME Annual == true)
Locate the earliest Monitor Method for location where ParameterCode = "NOXM", BeginDate is on or before the last day
of the Current Reporting Period, and EndDate is null or is on or after Jan 1 of the year of the Current Reporting Period.
else
if {Current Monitor Plan Location Record.LocationName begins with "MS" OR Multiple Stack Configuration == false)
Locate the earliest Monitor Method for location where ParameterCode = "NOXR", BeginDate is on or before the
last day of the Current Reporting Period, and EndDate is null or is on or after Jan 1 of the year of the Current
Reporting Period.
else
Locate the earliest Monitor Method for ALL locations in the monitor plan where ParameterCode = "NOXR".
BeginDate is on or before the last day of the Current Reporting Period, and EndDate is null or is on or after Jan 1
of the year of the Current Reporting Period.
If the NOXR or NOXM method record was found,
Environmental Protection Agency
Page 164 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Locate the earliest Location Program Record for location where ProgramCode is equal to "ARP", the Class is not equal to
"NA", and UnitMonitorCertBeginDate is on or before the last day of the Current Reporting Period, and the EndDate is
null or is on or after Jan 1 of the year of the Current Reporting Period.
If found,
If the EmissionsRecordingBeginDate is null,
If the later of the method BeginDate and the UnitMonitorCertBeginDate is in a year prior to the current
reporting period,
Set NOXR Start Quarter to 1.
else
Set NOXR Start Quarter to the quarter of the later of the method BeginDate and
UnitMonitorCertBeginDate.
Otherwise,
If the later of the method BeginDate and the EmissionsRecordingBeginDate is in a year prior to the
current reporting period,
Set NOXR Start Quarter to 1.
else
Set NOXR Start Quarter to the quarter of the later of the method BeginDate and
EmissionsRecordingBeginDate.
Locate the earliest Monitor Method for location where ParameterCode = "C02" or "C02M", BeginDate is on or before the last day
of the Current Reporting Period, and EndDate is null or is on or after Jan 1 of the year of the Current Reporting Period.
If found,
If BeginDate is in a year prior to the current reporting period,
Set CO2 Start Quarter to 1.
else
Set CO2 Start Quarter to the quarter of the BeginDate.
If (the Quarter of the Current Reporting Period is greater than 2 OR (Annual Reporting Requirement == true AND the Quarter of the
Current Reporting Period is equal to 2))
Locate the earliest Monitor Method for location where ParameterCode = "HI" or "HIT", MethodCode is not equal to "EXP",
BeginDate is on or before the last day of the Current Reporting Period, and EndDate is null or is on or after Jan 1 of the year of the
Current Reporting Period.
If found,
If BeginDate is in a year prior to the Current Reporting Period,
If Annual Reporting Requirement == true
Set Heat Input Start Quarter to 1
else
Set Heat Input Start Quarter to 2
else if BeginDate is in Quarter 1 of the year of the Current Reporting Period AND Annual Reporting Requirement ==
false,
Set Heat Input Start Quarter to to 2
else
Set Heat Input Start Quarter to the quarter of the BeginDate.
Locate the earliest Monitor Method for location where ParameterCode is equal to "NOX" or "NOXM", BeginDate is on or before
the last day of the Current Reporting Period, and EndDate is null or is on or after Jan 1 of the year of the Current Reporting
Period.
If found,
If BeginDate is in a year prior to the Current Reporting Period,
Environmental Protection Agency
Page 165 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
If Annual Reporting Requirement == true
Set NOXStart Quarter to 1
else
Set NOX Start Quarter to 2
else if BeginDate is in Quarter 1 of the year of the Current Reporting Period AND Annual Reporting Requirement ==
false,
Set NOX Start Quarter to to 2
else
Set NOX Start Quarter to the quarter of the BeginDate.
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Summary Value Evaluation
Environmental Protection Agency
Page 166 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAGG-2
Check Name: Compare S02 Mass Accumulator Values
Related Former Checks:
Applicability:
Description:
Validation Tables:
[Quarterly Emissions Tolerances] (Cross Check Table)
Specifications:
S02 Mass Quarterly Tolerance = Lookup Tolerance from Cross-Check Table "Quarterly Emissions Tolerances" where
Parameter = "S02M" AND
UOM = "TON"
Current S02 Summary Value Record = Summary Value record at this location where
Parameter = "S02M" AND
Reporting Period ID = Current Reporting Period
if (Rpt Period S02 Mass Calculated Accumulator Array for this location == -1 OR Expected Summary Value S02 Array for this location
== false)
Rpt Period S02 Mass Calculated Value = null
else
Rpt Period S02 Mass Calculated Value = {Rpt Period S02 Mass Calculated Accumulator Array for this location / 2000, and
rounded to one decimal place).
if (Rpt Period S02 Mass Reported Accumulator Array for this location >= 0)
Rpt Period S02 Mass Reported Accumulator Array for this location = (Rpt Period S02 Mass Reported Accumulator Array for
this location/ 2000, and rounded to one decimal place).
if (Current SO2 Summary Value Record is null OR Current SO2 Summary Value Record. Current Reporting Period Total is null)
if (Expected Summary Value S02 Array for this location == true)
return result C
else
if (Expected Summary Value S02 Array for this location == false)
if (Rpt Period Op Hours Accumulator Array for this Location is not equal to 0 OR Current S02 Summary Value
Record. Current Reporting Period Total is not equal to 0)
return result D
else
S02 Mass Quarterly Reported Value = Current S02 Summary Value Record. Current Reporting Period Total
if (S02 Mass Quarterly Reported Value < 0)
return result F
else if (S02 Mass Quarterly Reported Value is not rounded to one decimal place)
return result G
else if (Rpt Period S02 Mass Calculated Value is not null)
If (Rpt Period S02 Mass Calculated Value <> S02 Mass Quarterly Reported Value)
if (ABS(Rpt Period S02 Mass Calculated Value - S02 Mass Quarterly Reported Value) > S02 Mass
Quarterly Tolerance)
return Result A
else
append "S02M" to Emissions ToleranceDeviators.
else
Environmental Protection Agency
Page 167 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
return result E
// if no result
if (Rpt Period S02 Mass Reported Accumulator Array for this location >= 0 AND A B S( Rpt Period S02 Mass Reported
Accumulator Array for this location - S02 Mass Quarterly Reported Value) > S02 Mass Quarterly Tolerance)
Reported Emissions Value = Rpt Period S02 Mass Reported Accumulator Array for this location
return result B
Results:
Result
A
B
C
D
E
F
G
Response
The CurrentReportingPeriodTotalof [sumval] reported in the Summary Value record
for S02M for the reporting period is inconsistent with the recalculated value of
[calcval].
The CurrentReportingPeriodTotalof [sumval] reported in the Summary Value record
for S02M is inconsistent with [sum], the sum of the hourly values reported in the DHV
records for the reporting period.
The CurrentReportingPeriodTotal in the Summary Value record for S02M is missing
or the record is missing.
You reported a value as the CurrentReportingPeriodTotal in the Summary Value record
for S02M, but there were no Hourly Operating Data records or appropriate S02
Methods defined in your monitoring plan.
The CurrentReportingPeriodTotal in the Summary Value record for [param] could not
be recalculated because of errors listed above.
The CurrentReportingPeriodTotal reported in the Summary Value record for [param] is
invalid. The value must be greater than or equal to 0.
You reported [fieldname] in the [type] record for [param] that is not rounded to the
appropriate precision for that parameter.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1
Process/Category: Emissions Data Evaluation Report Summary Value Evaluation
Environmental Protection Agency
Page 168 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAGG-3
Check Name: Compare C02 Mass Accumulator Values
Related Former Checks:
Applicability:
Description:
Validation Tables:
[Quarterly Emissions Tolerances] (Cross Check Table)
Specifications:
If Current Reporting Period Year is greater than or equal to 2012
C02 Mass Quarterly Tolerance = Lookup Tolerance from Cross-Check Table "Quarterly Emissions Tolerances" where
Parameter = "C02M" AND
UOM = "TON"
else
C02 Mass Quarterly Tolerance = Lookup Tolerance from Cross-Check Table "Quarterly Emissions Tolerances" where
Parameter = "C02M-OLD" AND
UOM = "TON"
Current C02 Summary Value Record = Summary Value record at this location where
Parameter = "C02M" AND
Reporting Period ID = Current Reporting Period
if (Rpt Period C02 Mass Calculated Accumulator Array for this location < 0 OR Expected Summary Value C02 Array for this location
== false)
Rpt Period C02 Mass Calculated Value = null
else
Rpt Period C02 Mass Calculated Value = Rpt Period C02 Mass Calculated Accumulator Array for this location, rounded to one
decimal place.
if {Rpt Period C02 Mass Reported Accumulator Array for this location >= 0)
Rpt Period C02 Mass Reported Accumulator Array for this location = (Rpt Period C02 Mass Reported Accumulator Array for
this location, rounded to one decimal place).
if (Current CO2 Summary Value Record is null OR Current C02 Summary Value Record. Current Reporting Period Total is null)
if (Expected Summary Value C02 Array for this location == true)
return result C
else
if (Expected Summary Value C02 Array for this location == false)
if {Rpt Period Op Hours Accumulator Array for this Location is not equal to 0 OR Current C02 Summary Value
Record. Current Reporting Period Total is not equal to 0)
return result D
else
C02 Mass Quarterly Reported Value = Current C02 Summary Value Record. Current Reporting Period Total
if (C02 Mass Quarterly Reported Value < 0)
return result F
else if (C02 Mass Quarterly Reported Value is not rounded to one decimal place)
return result G
else if {Rpt Period C02 Mass Calculated Value is not null)
if {Rpt Period C02 Mass Calculated Value <> C02 Mass Quarterly Reported Value)
if (ABS{Rpt Period C02 Mass Calculated Value - C02 Mass Quarterly Reported Value) > C02 Mass
Quarterly Tolerance)
return Result A
else
Environmental Protection Agency
Page 169 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
append "C02M" to Emissions Tolerance Deviators.
else
if (Rpt Period C02 Mass Calculated Accumulator Array for this location == -1)
return result E
// if no result
if {Rpt Period C02 Mass Reported Accumulator Array for this location >= 0 AND ABS(Rpt Period C02 Mass Reported
Accumulator Array for this location - C02 Mass Quarterly Reported Value) > C02 Mass Quarterly Tolerance)
Reported Emissions Value = Rpt Period C02 Mass Reported Accumulator Array for this location
return Result B
Results:
Result
A
B
C
D
E
F
G
Response
The CurrentReportingPeriodTotalof [sumval] reported in the Summary Value record
for C02M for the reporting period is inconsistent with the recalculated value of
[calcval].
The CurrentReportingPeriodTotalof [sumval] reported in the Summary Value record
for C02M is inconsistent with [sum], the sum of the hourly values reported in the DHV
records for the reporting period.
The CurrentReportingPeriodTotal in the Summary Value record for C02M is missing
or the record is missing.
You reported a value for the CurrentReportingPeriodTotal in the Summary Value
record for [param], but there was no emissions data in your file or an appropriate C02
Method defined in your monitoring plan.
The CurrentReportingPeriodTotal in the Summary Value record for [param] could not
be recalculated because of errors listed above.
The CurrentReportingPeriodTotal reported in the Summary Value record for [param] is
invalid. The value must be greater than or equal to 0.
You reported [fieldname] in the [type] record for [param] that is not rounded to the
appropriate precision for that parameter.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1
Process/Category: Emissions Data Evaluation Report Summary Value Evaluation
Environmental Protection Agency
Page 170 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAGG-4
Check Name: Compare HI Accumulator Values
Related Former Checks:
Applicability:
Description:
Validation Tables:
[Quarterly Emissions Tolerances] (Cross Check Table)
Specifications:
HI Quarterly Tolerance = Lookup Tolerance from Cross-Check Table "Quarterly Emissions Tolerances" where
Parameter = "HIT" AND
UOM = "MMBTU"
Current HI Summary Value Record = Summary Value record at this location where
Parameter = "HIT" AND
Reporting Period ID = Current Reporting Period
if (Rpt Period HI Calculated Accumulator Array for this location == -1 OR Expected Summary Value HI Array for this location == false)
Rpt Period HI Calculated Value = null
else
Rpt Period HI Calculated Value = Rpt Period HI Calculated Accumulator Array for this location, rounded to zero decimal places.
if (Rpt Period HI Reported Accumulator Array for this location >= 0)
Rpt Period HI Reported Accumulator Array for this location = (Rpt Period HI Reported Accumulator Array for this location,
rounded to zero decimal places).
if (Current HI Summary Value Record is null OR Current HI Summary Value Record.Current Reporting Period Total is null)
if (Expected Summary Value HI Array for this location == true)
return result C
else
if (Expected Summary Value HI Array for this location == false)
if (Rpt Period Op Hours Accumulator Array for this Location is not equal to 0 OR Current HI Summary Value
Record. Current Reporting Period Total is not equal to 0)
return result D
else
HI Quarterly Reported Value = Current HI Summary Value Record.Current Reporting Period Total
if (HI Quarterly Reported Value < 0)
return result F
else if (HI Quarterly Reported Value is not rounded to zero decimal places)
return result G
else if (Rpt Period HI Calculated Value is not null)
if (Rpt Period HI Calculated Value <> HI Quarterly Reported Value)
if (ABS(Rpt Period HI Calculated Value - HI Quarterly Reported Value) > HI Quarterly Tolerance)
return result A
else
append "HIT" to Emissions Tolerance Deviators.
else
return result E
// if no result
if (Rpt Period HI Reported Accumulator Array for this location >= 0 AND ABS(Rpt Period HI Reported Accumulator
Array for this location (rounded to zero decimal places) - HI Quarterly Reported Value) > HI Quarterly Tolerance)
Reported Emissions Value = Rpt Period HI Reported Accumulator Array for this location
Environmental Protection Agency
Page 171 of 850
-------
Draft ECMPS Emissions Check Specifications
return Result B
6/17/2015 12:00:00AM
Results:
Result
A
B
C
D
E
F
G
Response
The CurrentReportingPeriodTotal of [sumval] reported in the Summary Value record
for HIT for the reporting period is inconsistent with the recalculated value of [calcval].
The CurrentReportingPeriodTotal of [sumval] reported in the Summary Value record
for HIT is inconsistent with [sum], the sum of the hourly values reported in the DHV
records for the reporting period.
The CurrentReportingPeriodTotal in the Summary Value record for HIT is missing or
the record is missing.
You reported a value as the CurrentReportingPeriodTotal in the Summary Value record
for HIT, but there were no Hourly Operating Data records or appropriate HI Methods
defined in your monitoring plan.
The CurrentReportingPeriodTotal in the Summary Value record for [param] could not
be recalculated because of errors listed above.
The CurrentReportingPeriodTotal reported in the Summary Value record for [param] is
invalid. The value must be greater than or equal to 0.
You reported [fieldname] in the [type] record for [param] that is not rounded to the
appropriate precision for that parameter.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1
Process/Category: Emissions Data Evaluation Report Summary Value Evaluation
Environmental Protection Agency
Page 172 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAGG-5
Check Name: Compare Op Hours Values
Related Former Checks:
Applicability:
Description:
Validation Tables:
[Quarterly Emissions Tolerances] (Cross Check Table)
Specifications:
Op Hours Quarterly Tolerance = Lookup Tolerance from Cross-Check Table "Quarterly Emissions Tolerances" where
Parameter = "OPHOURS" AND
UOM = "HR"
Current Op Hours Summary Value Record = Summary Value record at this location where
Parameter = "OPHOURS" AND
Reporting Period ID = Current Reporting Period
if (Rpt Period Op Hours Accumulator Array for this location == -1 OR (LME HI Method is not null and location is a common pipe))
Rpt Period Op Hours Calculated Value = null
Rpt Period Op Days Calculated Value = null
else
Rpt Period Op Hours Calculated Value = Rpt Period Op Hours Accumulator Array for this location
Rpt Period Op Days Calculated Value = Rpt Period Op Days Accumulator Array for this location
if (Current Op Hours Summary Value Record is null OR Current Op Hours Summary Value Record. Current Reporting Period Total is
null)
If (LME HI Method is null or location is not a common pipe)
return result B
else
Op Hours Quarterly Reported Value = Current Op Hours Summary Value Record. Current Reporting Period Total
if (Op Hours Quarterly Reported Value < 0)
return result D
else if (Op Hours Quarterly Reported Value is not rounded to zero decimal places)
return result E
else if (Rpt Period Op Hours Calculated Value is not null)
if (Rpt Period Op Hours Calculated Value <> Op Hours Quarterly Reported Value)
if ( ABS(Rpt Period Op Hours Calculated Value - Op Hours Quarterly Reported Value) > Op Hours Quarterly
Tolerance)
return Result A
else
append "OPHOURS" to Emissions Tolerance Deviators.
else
return result C
Environmental Protection Agency
Page 173 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
B
C
D
E
Usage:
1
Response
The CurrentReportingPeriodTotal of [sumval] reported in the Summary Value record
for OPHOURS is inconsistent with [calcval], the number of operating hours reported in
the Hourly Operating Data records for the reporting period.
The CurrentReportingPeriodTotal in the Summary Value record for OPHOURS is
missing or the record is missing.
The CurrentReportingPeriodTotal in the Summary Value record for [param] could not
be recalculated because of errors listed above.
The CurrentReportingPeriodTotal reported in the Summary Value record for [param] is
invalid. The value must be greater than or equal to 0.
You reported [fieldname] in the [type] record for [param] that is not rounded to the
appropriate precision for that parameter.
Process/Category: Emissions Data Evaluation Report Summary Value Evaluation
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 174 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAGG-6
Check Name: Compare Op Time Values
Related Former Checks:
Applicability:
Description:
Validation Tables:
[Quarterly Emissions Tolerances] (Cross Check Table)
Specifications:
Op Time Quarterly Tolerance = Lookup Tolerance from Cross-Check Table "Quarterly Emissions Tolerances" where
Parameter = "OPTIME" AND
UOM = "HR"
Current Op Time Summary Value Record = Summary Value record at this location where
Parameter = "OPTIME" AND
Reporting Period ID = Current Reporting Period
if {Rpt Period Op Time Accumulator Array for this location == -1 OR (LME HI Method is not null and location is a common pipe))
Rpt Period Op Time Calculated Value = null
else
Rpt Period Op Time Calculated Value = Rpt Period Op Time Accumulator Array for this location
if (Current Op Time Summary Value Record is null OR Current Op Time Summary Value Record. Current Reporting Period Total is null)
If (LME HI Method is null or location is not a common pipe)
if (Legacy Data Evaluation == true)
return result B
else
return result E
else
Op Time Quarterly Reported Value = Current Op Time Summary Value Record.Current Reporting Period Total
if (Op Time Quarterly Reported Value >= 0)
if (Op Time Quarterly Reported Value is not rounded to two decimal places)
return result F
else
if (Rpt Period Op Time Calculated Value is not null)
if {Rpt Period Op Time Calculated Value <> Op Time Quarterly Reported Value)
if (ABS{Rpt Period Op Time Calculated Value - Op Time Quarterly Reported Value) > Op Time
Quarterly Tolerance)
return A
else
append "OPTIME" to Emissions Tolerance Deviators.
else
return result D
else
return result C
Environmental Protection Agency
Page 175 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
B
C
D
E
F
Usage:
1
Response
The CurrentReportingPeriodTotal of [sumval] reported in the Summary Value record
for OPTIME is inconsistent with [calcval], the sum of the hourly values reported in the
Hourly Operating Data records for the reporting period.
You did not report a Summary Value record for OPTIME for the reporting period.
While this information was not required for legacy EDR data, it is required for ECMPS.
The CurrentReportingPeriodTotal reported in the Summary Value record for OPTIME
is invalid. The value must be greater than or equal to 0.
The CurrentReportingPeriodTotal in the Summary Value record for [param] could not
be recalculated because of errors listed above.
The CurrentReportingPeriodTotal in the Summary Value record for OPTIME is missing
or the record is missing.
You reported [fieldname] in the [type] record for [param] that is not rounded to the
appropriate precision for that parameter.
Process/Category: Emissions Data Evaluation Report Summary Value Evaluation
Severity
Critical Error Level 1
Informational Message
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 176 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAGG-7
Check Name:
Compare NOx Rate Accumulator Values
Related Former Checks:
Applicability:
Description:
Validation Tables:
[Quarterly Emissions Tolerances] (Cross Check Table)
Specifications:
If (Expected Summary Value NOx Rate Array for this location == true)
if (LME Annual == true)
if (Rpt Period HI Calculated Value is not null and Rpt Period NOx Mass Calculated Value is not null)
If (Rpt Period NOx Mass Calculated Accumulator Array for this location = 0)
Rpt Period NOx Rate Calculated Value = 0
else
Rpt Period NOx Rate Calculated Value = Rpt Period NOx Mass Calculated Accumulator Array for this
location / Rpt Period HI Calculated Value, and round the result to three decimal places
if (Rpt Period NOx Rate Hours Accumulator Array for this location > 0 AND Rpt Period NOx Rate Calculated
Accumulator Array for this location >= 0)
Rpt Period NOx Rate Calculated Value = Rpt Period NOx Rate Calculated Accumulator Array for this location /
Rpt Period NOx Rate Hours Accumulator Array for the location, and round the result to three decimal places
Rpt Period NOx Rate Sum = Rpt Period NOx Rate Calculated Accumulator Array for this location
Rpt Period NOx Rate Hours = Rpt Period NOx Rate Hours Accumulator Array for this location
else if (Rpt Period NOx Rate Hours Accumulator Array for this location == 0 AND Rpt Period NOx Rate Calculated
Accumulator Array for this location == 0)
Rpt Period NOx Rate Calculated Value = 0
Rpt Period NOx Rate Sum = 0
Rpt Period NOx Rate Hours = 0
else
Rpt Period NOx Rate Calculated Value = null
Rpt Period NOx Rate Sum = null
Rpt Period NOx Rate Hours = null
if (Rpt Period NOx Rate Hours Accumulator Array for this location > 0 AND Rpt Period NOx Rate Reported
Accumulator Array for this location >= 0)
Rpt Period NOx Rate Reported Accumulator Array for this location = Rpt Period NOx Rate Reported
Accumulator Array for this location / Rpt Period NOx Rate Hours Accumulator Array for this location, and
round the result to three decimal places
else
Rpt Period NOx Rate Reported Accumulator Array for this location = -1
else
Rpt Period NOx Rate Calculated Value = null
NOx Rate Quarterly Tolerance = Lookup Tolerance from Cross-Check Table "Quarterly Emissions Tolerances" where
Parameter = "NOXR" AND
UOM = "LBMMBTU"
Current NOx Rate Summary Value Record = Summary Value record at this location where
Parameter = "NOXR" AND
Reporting Period ID = Current Reporting Period
if (Current NOx Rate Summary Value Record is null OR Current NOx Rate Summary Value Record. Current Reporting Period Total is
else
Rpt Period NOx Rate Calculated Value = null
else
Environmental Protection Agency
Page 177 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
if (Expected Summary Value NOx Rate Array for this location == false)
if (Rpt Period NOx Rate Hours Accumulator Array for this Location is not equal to 0 OR Current NOx Rate Summary
Value Record. Current Reporting Period Total is not null)
NOx Rate Quarterly Reported Value = Current NOx Rate Summary Value Record. Current Reporting Period Total
If (NOx Rate Quarterly Reported Value < 0)
return result F
else if (Rpt Period NOx Rate Calculated Value is not null)
if (ABS{Rpt Period NOx Rate Calculated Value - NOx Rate Quarterly Reported Value) > NOx Rate Quarterly
Tolerance)
return result A
//if no result
if {LME Annual == false)
if {Current Monitor Plan Location Record. LocationNamc begins with "MS" OR Multiple Stack Configuration
== false)
if {Rpt Period NOx Rate Reported Accumulator Array for this location >= 0 AND ABS {Rpt Period NOx
Rate Reported Accumulator Array for this location - NOx Rate Quarterly Reported Value) > NOx Rate
Quarterly Tolerance)
Reported Emissions Value = Rpt Period NOx Rate Reported Accumulator Array for this
location
return Result B
return result D
else
return result E
Environmental Protection Agency
Page 178 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
B
C
D
E
F
Usage:
1
Response
The CurrentReportingPeriodTotal of [sumval] reported in the Summary Value record
for NOXR for the reporting period is inconsistent with the recalculated value of
[calcval].
The CurrentReportingPeriodTotal of [sumval] reported in the Summary Value record
for NOXR is inconsistent with [average], the average of the hourly values reported in
the DHV records for the reporting period.
The CurrentReportingPeriodTotal in the Summary Value record for NOXR is missing
or the record is missing.
You reported a value as the CurrentReportingPeriodTotal in the Summary Value record
for NOXR, but this is not appropriate, either because there were no Hourly Operating
Data records in your emissions file, or because this value is not consistent with the unit
program records and monitoring methodologies in your monitoring plan.
The CurrentReportingPeriodTotal in the Summary Value record for [param] could not
be recalculated because of errors listed above.
The CurrentReportingPeriodTotal reported in the Summary Value record for [param] is
invalid. The value must be greater than or equal to 0.
Process/Category: Emissions Data Evaluation Report Summary Value Evaluation
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 179 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAGG-8
Check Name: Compare NOx Mass Accumulator Values
Related Former Checks:
Applicability:
Description:
Validation Tables:
[Quarterly Emissions Tolerances] (Cross Check Table)
Specifications:
NOx Mass Quarterly Tolerance = Lookup Tolerance from Cross-Check Table "Quarterly Emissions Tolerances" where
Parameter = "NOXM" AND
UOM = "TON"
Current NOx Mass Summary Value Record = Summary Value record at this location where
Parameter = "NOXM" AND
Reporting Period ID = Current Reporting Period
if {Rpt Period NOx Mass Calculated Accumulator Array for this location == -1 OR Expected Summary Value NOx Mass Array for this
location == false)
Rpt Period NOx Mass Calculated Value = null
else
Rpt Period NOx Mass Calculated Value = Rpt Period NOx Mass Calculated Accumulator Array for this location / 2000, and
rounded to one decimal place).
if (Rpt Period NOx Mass Reported Accumulator Array for this location >= 0)
Rpt Period NOx Mass Reported Accumulator Array for this location = Rpt Period NOx Mass Reported Accumulator Array for
this location/ 2000, and rounded to one decimal place).
if (Current NOx Mass Summary Value Record is null OR Current NOx Mass Summary Value Record. Current Reporting Period Total is
null)
if (Expected Summary Value NOxMass Array for this location == true)
return result C
else
if (Expected Summary Value NOX Array for this location == false)
if (Rpt Period Op Hours Accumulator Array for this Location is not equal to 0 OR Current NOx Mass Summary Value
Record. Current Reporting Period Total is not equal to 0)
return result D
else
NOx Mass Quarterly Reported Value = Current NOx Mass Summary Value Record.Current Reporting Period Total
If (NOx Mass Quarterly Reported Value < 0)
return result F
else if (NOx Mass Quarterly Reported Value is not rounded to one decimal place)
return result G
else if (Rpt Period NOx Mass Calculated Value is not null)
if (Rpt Period NOx Mass Calculated Value <> NOx Mass Quarterly Reported Value)
if (ABS{Rpt Period NOx Mass Calculated Value - NOx Mass Quarterly Reported Value) > NOx Mass
Quarterly Tolerance)
return Result A
else
append "NOXM" to Emissions Tolerance Deviators.
else
return result E
Environmental Protection Agency
Page 180 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
// if no result
If (Rpt Period NOx Mass Reported Accumulator Array for this location >= 0 AND AB S(Rpt Period NOx Mass Reported
Accumulator Array for this location - NOx Mass Quarterly Reported Value) > NOx Mass Quarterly Tolerance)
Reported Emissions Value = Rpt Period NOx Mass Reported Accumulator Array for this location
return Result B
Results:
Result
B
C
D
E
F
G
Usage:
1
Response
The CurrentReportingPeriodTotalof [sumval] reported in the Summary Value record
for NOXM for the reporting period is inconsistent with the recalculated value of
[calcval].
The CurrentReportingPeriodTotalof [sumval] reported in the Summary Value record
for NOXM is inconsistent with [sum], the sum of the hourly values reported in the
DHV records for the reporting period.
The CurrentReportingPeriodTotal in the Summary Value record for NOXM is missing
or the record is missing.
You reported a value as the CurrentReportingPeriodTotal in the Summary Value record
for NOXM, but there were no Hourly Operating Data records or appropriate NOX
Methods defined in your monitoring plan.
The CurrentReportingPeriodTotal in the Summary Value record for [param] could not
be recalculated because of errors listed above.
The CurrentReportingPeriodTotal reported in the Summary Value record for [param] is
invalid. The value must be greater than or equal to 0.
You reported [fieldname] in the [type] record for [param] that is not rounded to the
appropriate precision for that parameter.
Process/Category: Emissions Data Evaluation Report Summary Value Evaluation
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 181 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAGG-10
Check Name:
Compare C02 Mass YTD Values
Related Former Checks:
Applicability:
Description:
Specifications:
Annual C02M Calculated Value = null
if (Rpt Period C02 Mass Calculated Value is not null OR Expected Summary Value C02 Array for this location == false)
if (Expected Summary Value C02 Array for this location == true)
else if (Quarter of the Current Reporting Period is greater than 1)
Annual C02M Calculated Value = 0
If (Quarter of the Current Reporting Period is greater than 1)
If (CO2 Start Quarter is not null)
For each quarter in the current year from the CO2 Start Quarter to the quarter prior to the quarter of the Current
Reporting Period:
Locate an Op Supp Data record for the location and quarter where ParameterCode = "C02M".
If not found,
if (Expected Summary Value C02 Array for this location == true)
set Annual C02M Calculated Value to null
return result A
Otherwise,
add OpValue to Annual C02M Calculated Value.
else
set Annual C02M Calculated Value to null
if (Current C02 Summary Value Record is not null)
If (Annual C02M Calculated Value is null AND Expected Summary Value C02 Array for this location == false)
return result G
else if (Current C02 Summary Value Ttecon/.YearToDateTotal is null or is less than 0)
return result B
else if (Current C02 Summary Value Record. YearToDateTotal is not rounded to one decimal place)
return result D
else if (Annual C02M Calculated Value is not null)
if {Annual C02M Calculated Value <> Current C02 Summary V(due Record. YearToDateTotal)
return result C
// If no result
If (Current C02 Summary Value /?6'ewY/.OzoncScasonToDatcTotal is not null)
Environmental Protection Agency Page 182 of 850
If (Emissions Tolerance Deviators contains "C02M")
Annual C02M Calculated Value = Current C02 Summary Value Record.Current Reporting Period Total
else
Annual C02M Calculated Value = Rpt Period C02 Mass Calculated Value
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
else
return result E
If (Expected Summary Value C02 Array for this location == false AND Annual C02M Calculated Value > 0)
return result F
Results:
Result
A
B
C
D
E
F
G
Usage:
1
Response
The program could not determine year-to-date for [param], because the Op Supp Data
record for this parameter is missing for one or more previous reporting periods. If you
have submitted emissions data for prior quarters, you should be able to retrieve these
records by logging on to the EPA host.
The [fieldname] in the Summary Value record for [param] is missing or invalid.
The YearToDateTotalof [ytdval] in the Summary Value record for [param] is
inconsistent with the recalculated value of [ytdcalc].
You reported [fieldname] in the [type] record for [param] that is not rounded to the
appropriate precision for that parameter.
You reported OzoneSeasonToDate in the Summary Value record for [param], but this is
not valid for this parameter.
You did not report a Summary Value record to report year-to-date total for [param].
You reported a Summary Value record for [param], but there was no [param] method
defined in your monitoring plan that was active during the year.
Process/Category: Emissions Data Evaluation Report Summary Value Evaluation
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 183 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAGG-11
Check Name: Compare S02 Mass YTD Values
Related Former Checks:
Applicability:
Description:
Specifications:
Annual S02M Calculated Value = null
if (Rpt Period S02 Mass Calculated Value is not null OR Expected Summary Value S02 Array for this location == false)
if (Expected Summary Value S02 Array for this location == true)
If (Emissions Tolerance Deviators contains "S02M")
AnnualS02M Calculated Value = Current S02 Summary Value Record. Current Reporting Period Total
else
AnnualS02M Calculated Value = Rpt Period S02 Mass Calculated Value
else if (Quarter of the Current Reporting Period is greater than 1)
Annual S02M Calculated Value = 0
If (Quarter of the Current Reporting Period is greater than 1)
If (S()2 Start Quarter is not null)
For each quarter from the SO2 Start Quarter to the quarter prior to the quarter of the Current Reporting Period.
Locate an Op Supp Data record for the location and quarter where ParameterCode = "S02M".
If not found,
if (Expected Summary Value S02 Array for this location == true)
set Annual S02M Calculated Value to null
return result A
Otherwise,
add OpValue to AnnualS02M Calculated Value
else
set Annual S02M Calculated Value to null
if (Current S02 Summary Value Record is not null)
if (Annual S02M Calculated Value is null AND Expected Summary Value S02 Array for this location == false)
return result H
else if (Current S02 Summary Value Record. YearToDateTotal is null or is less than 0)
return result B
else if (Current S02 Summary Value Record. Yca rTo DatcTota 1 is not rounded to one decimal place)
return result D
else if (Annual S02M Calculated Value is not null)
if (AnnualS02MCalculated Value<> Current S02 Summary ValueRecord.YcarToDatcTotal)
return result C
// if no result
if (Current S02 Summary Value Record. Ozo ne Seaso nTo DateTotal is not null)
Environmental Protection Agency
Page 184 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
return result F
else if {LME Annual is equal to true and Current S02 Summary Value Record. YearToDateTotal is greater than 25)
return result E
else
Results:
Result
If (Expected Summary Value S02 Array for this location == false AND Annual S02M Calculated Value > 0)
return result G
B
C
D
E
G
H
Usage:
1
Response
The program could not determine year-to-date for [param], because the Op Supp Data
record for this parameter is missing for one or more previous reporting periods. If you
have submitted emissions data for prior quarters, you should be able to retrieve these
records by logging on to the EPA host.
The [fieldname] in the Summary Value record for [param] is missing or invalid.
The YearToDateTotal of [ytdval] in the Summary Value record for [param] is
inconsistent with the recalculated value of [ytdcalc].
You reported [fieldname] in the [type] record for [param] that is not rounded to the
appropriate precision for that parameter.
The [paramname] emissions from this unit exceed the applicable number of tons
necessary to qualify as an LME unit. According to Part 75.19(b), you must install the
appropriate monitoring systems to measure [paramname] by December 31 of the year
following this reporting period.
You reported OzoneSeasonToDate in the Summary Value record for [param], but this is
not valid for this parameter.
You did not report a Summary Value record to report year-to-date total for [param].
You reported a Summary Value record for [param], but there was no [param] method
defined in your monitoring plan that was active during the year.
Process/Category: Emissions Data Evaluation Report Summary Value Evaluation
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Informational Message
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 185 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAGG-12
Check Name: Compare NOx Mass YTD and OS Values
Related Former Checks:
Applicability:
Description:
Validation Tables:
[Quarterly Emissions Tolerances] (Cross Check Table)
Specifications:
Annual NOXM Calculated Value = null
OS NOXM Calculated Value = null
NOXM Summary Invalid Fields = null
Imprecise Fields = null
if (Rpt Period NOx Mass Calculated Value is not null OR Expected Summary Value NOx Mass Array for this location == false)
if (Expected Summary Value NOx Mass Array for this location == true)
If {Annual Reporting Requirement == true)
If (Emissions Tolerance Deviators contains "NOXM")
Annual NOXM Calculated Value = Current NOX Mass Summary Value Record. Current Reporting
Period Total
else
Annual NOXM Calculated Value = Rpt Period NOx Mass Calculated Value
If (OS Reporting Requirement == true)
if (Quarter of the Current Reporting Period is equal to 2 or 3)
If (Annual Reporting Requirement == true AND the Quarter of the Current Reporting Period is equal to
2)
OS NOXM Calculated Value = (Rpt Period NOx Mass Calculated Accumulator Array for this
location - April NOx Mass Calculated Accumulator Array for this location) / 2000, rounded to
one decimal place.
else
If (Emissions Tolerance Deviators contains "NOXM")
OS NOXM Calculated Value = Current NOX Mass Summary Value Record. Current
Reporting Period Total
else
OS NOXM Calculated Value = Rpt Period NOx Mass Calculated Value
else if (Quarter of the Current Reporting Period is equal to 4)
OS NOXM Calculated Value = 0
else
If (Annual Reporting Requirement == true AND the Quarter of the Current Reporting Period is greater than 1)
Annual NOXM Calculated Value = 0
If (OS Reporting Requirement == true AND the Quarter of the Current Reporting Period is greater than 2)
OS NOXM Calculated Value = 0
If (the Quarter of the Current Reporting Period is greater than 2 OR (Annual Reporting Requirement == true AND the Quarter of
the Current Reporting Period is equal to 2))
If (NOXStart Quarter is not null)
For each quarter in the current year from the NOX Start Quarter to the quarter prior to the quarter of the Current
Reporting Period:
Environmental Protection Agency
Page 186 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
If this quarter is equal to 2 AND OS Reporting Requirement == true,
Locate an Op Supp Data record for the location and quarter where ParameterCode = "NOXMOS".
If not found,
if (Expected Summary Value NOx Mass Array for this location == true)
set Annual NOXM Calculated Value to null,
set OS NOXM Calculated Value to null
return result A
otherwise,
Locate an Op Supp Data record for the location and quarter where
ParameterCode = "NOXM".
If found,
set Annual NOXM Calculated Value to null,
set OS NOXM Calculated Value to null
return result A
Otherwise,
add OpValue to OS NOXM Calculated Value.
If this quarter is not equal to 2 OR Annual Reporting Requirement == true,
Locate an Op Supp Data record for the location and quarter where ParameterCode = "NOXM".
If not found,
if (Expected Summary Value NOx Mass Array for this location == true)
set Annual NOXM Calculated Value to null,
set OS NOXM Calculated Value to null
return result B
Otherwise,
if Annual Reporting Requirement == true
add OpValue to Annual NOXM Calculated Value
if this quarter is equal to 3 AND OS Reporting Requirement == true
add OpValue to OS NOXM Calculated Value.
else
set Annual NOXM Calculated Value to null
set OS NOXM Calculated Value to null
if (Current NOX Mass Summary Value Record is not null)
If (OS NOXM Calculated Value Value is null AND Annual NOXM Calculated Value is null AND Expected Summary
Value NOx Mass Array for this location == false)
return result K
Otherwise,
If (Current NOX Mass Summary Value Record. Y carToDatcT otal is null and Annual Reporting Requirement ==
true) OR (Current NOX Mass Summary Value YcarToDatcT otal is less than 0,
append "YearToDateTotal" to NOXM Summary Invalid Fields
If (Current NOX Mass Summary Value /?6'cwY/.OzoneSeasonToDateTotal is null and OS Reporting
Requirement == true AND Quarter of the Current Reporting Period is equal to 2 or 3 or 4), OR Current NOX
Mass Summary Value Record.OzoneSeasonToDateTota 1 is less than 0,
append "OzoneSeasonToDateTotal" to NOXM Summary Invalid Fields
Environmental Protection Agency
Page 187 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
If {Current NOXMass Summary Value Record. YearToDateTotal is not rounded to one decimal place)
append "YearToDateTotal" to Imprecise Fields
If {Current NOX Mass Summary Value Record. O zo ne S ea so 11T0 D ateTo ta 1 is not rounded to one decimal place)
append "OzoneSeasonToDateTotal" to Imprecise Fields
If {NOXM Summary Invalid Fields is not null)
return result C
else if {Imprecise Fields is not null)
Set NOXM Summary Invalid Fields to Imprecise Fields
return result E
else if {Annual NOXM Calculated Value is not null OR OS NOXM Calculated Value is not null)
Tolerance = Lookup Tolerance from Cross-Check Table "Quarterly Emissions Tolerances" where
Parameter = "NOXM" AND
UOM = "TON"
if {Annual NOXM Calculated Value is not null AND Annual NOXM Calculated Value <> Current
NOX Mass Summary Value Ttecon/.YearToDateTotal)
append "YearToDateTotal" to NOXM Summary Invalid Fields
if {OS NOXM Calculated Value is not null AND OS NOXM Calculated Value <> Current NOX Mass
Summary Value Record. OzoneSeasonToDateTotal)
if (ABS(OS' NOXM Calculated Value - Current NOXM Summary Value
Record. Ozo ncScasonToDateTotal) > Tolerance OR quarter of the Current Reporting Period is
greater than 2)
append "OzoneSeasonToDateTotal" to NOXM Summary Invalid Fields
If NOXM Summary Invalid Fields is not null,
If {NOXM Summary Invalid Fields contains "Year")
If {NOXM Summary Invalid Fields contains "Ozone")
return result D
else
return result H
else
return result I
// if no result
if {OS Reporting Requirement == false and Current NOXM Summary Value Record. OzoneSeasonToDateTotal
is not null)
return result G
else if {Annual Reporting Requirement == false and Current NOXM Summary Value Record. YearToDateTotal
is not null)
return result L
else if {{LME Annual is equal to true and Current NOXM Summary Value Record. YearToDateTotal is greater
than 100) OR {LME OS is equal to true and Current NOXM Summary Value /?6'ewY/.OzoncScasonToDatcTotal
is greater than 50))
return result F
else
If {Expected Summary Value NOx Mass Array for this location == false AND {OS NOXM Calculated Value > 0 OR
Annual NOXM Calculated Value > 0))
return result J
Environmental Protection Agency
Page 188 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
B
C
D
E
F
G
H
I
J
K
Usage:
1
Response
The program could not determine ozone-season-to-date totals for [osparam], because
the Op Supp Data record for this parameter is missing for one or more previous
reporting periods. If you have submitted emissions data for prior quarters, you should
be able to retrieve these records by logging on to the EPA host.
The program could not determine year-to-date for [param], because the Op Supp Data
record for this parameter is missing for one or more previous reporting periods. If you
have submitted emissions data for prior quarters, you should be able to retrieve these
records by logging on to the EPA host.
The [fieldname] in the Summary Value record for [param] is missing or invalid.
The YearToDateTotalof [ytdval] in the Summary Value record for [param] is
inconsistent with the recalculated value of [ytdcalc], and the OzoneSeasonToDateTotal
cf [osval] in the Summary Value record for [param] is inconsistent with the recalculated
value of [oscalc].
You reported [fieldname] in the [type] record for [param] that is not rounded to the
appropriate precision for that parameter.
The [paramname] emissions from this unit exceed the applicable number of tons
necessary to qualify as an LME unit. According to Part 75.19(b), you must install the
appropriate monitoring systems to measure [paramname] by December 31 of the year
following this reporting period.
You reported OzoneSeasonToDate in the Summary Value record for [param], but this is
not valid for locations that are not associated with an ozone-season program.
The YearToDateTotalof [ytdval] in the Summary Value record for [param] is
inconsistent with the recalculated value of [ytdcalc].
The OzoneSeasonToDateTotal of [osval] in the Summary Value record for [param] is
inconsistent with the recalculated value of [oscalc].
You did not report a Summary Value record to report year-to-date total for [param].
You reported a Summary Value record for [param], but there was no [param] method
defined in your monitoring plan that was active during the year.
You reported YearToDate in the Summary Value record for [param], but this is not
valid for locations that only report during the ozone season.
Process/Category: Emissions Data Evaluation Report Summary Value Evaluation
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Informational Message
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 189 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAGG-13
Check Name: Compare NOx Rate YTD Values
Related Former Checks:
Applicability:
Description:
Validation Tables:
[Quarterly Emissions Tolerances] (Cross Check Table)
Specifications:
Annual NOXR Calculated Value = null
If (LMEAnnual == true)
Set Total NOx Mass to null.
if (Expected Summary Value NOx Rate Array for this location == true)
if (Rpt Period NOx Mass Calculated Accumulator Array for this location is greater than or equal to 0 AND Rpt Period HI
Calculated Value is not null)
Set Total NOx Mass to Rpt Period NOx Mass Calculated Accumulator Array for this location.
Set Total HI to Rpt Period HI Calculated Value.
else if (Quarter of the Current Reporting Period is greater than 1)
Set Total NOx Mass to 0.
Set Total HI to 0.
If (Quarter of the Current Reporting Period is greater than 1 AND Total NOx Mass is not null)
if (NOXR Start Quarter is not null)
For each quarter in the current year from the NOXR Start Quarter to the quarter prior to the quarter of the Current
Reporting Period:
Locate an Op Supp Data record for the location and quarter where ParameterCode = "NOXR".
If not found,
if (Expected Summary Value NOx Rate Array for this location == true)
set Total NOx Mass to null,
return result A
Otherwise,
set NOX Value to OpValue.
Locate an Op Supp Data record for the location and quarter where ParameterCode = "HIT".
If not found,
if (Expected Summary Value NOx Rate Array for this location == true)
set Total HI to null,
return result E
Otherwise,
Add OpValue to Total HI.
Calculate NOX Value = NOX Value * OpValue, and round the result to 1 decimal place.
Add NOX Value to Total NOx Mass.
Environmental Protection Agency
Page 190 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
else
Set Total NOxMass to null.
If (Total NOxMass is not null AND Total HI is not null)
If (Total NOxMass == 0)
Set Annual NOXR Calculated Value to 0.
else
Calculate Annual NOXR Calculated Value = Total NOx Mass / TotalHI, and round the result to 3 decimal places.
Set TotalOpHours to null.
if (Expected Summary Value NOx Rate Array for this location == true)
if (Rpt Period NOx Rate Calculated Value is not null)
Annual NOXR Calculated Value = Rpt Period NOx Rate Sum
Set TotalOpHours to Rpt Period NOx Rate Hours.
else if ((Quarter of the Current Reporting Period is greater than 1)
Set TotalOpHours to 0.
If (Quarter of the Current Reporting Period is greater than 1 AND TotalOpHours is not null)
if (NOXR Start Quarter is not null)
For each quarter from the NOXR Start Quarter to the quarter prior to the quarter of the Current Reporting Period.
Locate an Op Supp Data record for the location and quarter where ParameterCode = "NOXRSUM".
If found,
Add OpValue to Annual NOXR Calculated Value
Locate an Op Supp Data record for the location and quarter where ParameterCode =
"NOXRHRS".
If found,
Add OpValue to TotalOpHours.
If not found,
set Annual NOXR Calculated Value to null
return result A
Otherwise,
Locate an Op Supp Data record for the location and quarter where ParameterCode = "NOXR".
If not found,
if (Expected Summary Value NOx Rate Array for this location == true)
set Annual NOXR Calculated Value to null
return result A
Otherwise,
set NOXVal to OpValue
Locate an Op Supp Data record for the location and quarter where ParameterCode =
"OPHOURS" and FuelCode is null.
Environmental Protection Agency
Page 191 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
If not found,
if (Expected Summary Value NOx Rate Array for this location == true)
set Annual NOXR Calculated Value to null
return result B
Otherwise,
Add OpValue to TotalOpHours.
Add OpValue * NOXVal to Annual NOXR Calculated Value
else
set Annual NOXR Calculated Value to null.
If {Annual NOXR Calculated Value is not null)
If (TotalOpHours == 0)
Set Annual NOXR Calculated Valueto 0.
else if (Annual NOXR Calculated Value > 0)
Calculate Annual NOXR Calculated Value = Annual NOXR Calculated Value / TotalOpHours, and round the
result to 3 decimal places.
if (Current NOXR Summary Value Record is not null)
If {Annual NOXR Calculated Value is null AND Expected Summary Value NOx Rate Array for this location == false)
return result H
else if {Current NOXR Summary Value Record. Y earToDateTotal is null oris less thanO)
return result C
else if {Annual NOXR Calculated Value is not null)
if {Annual NOXR Calculated Value <> Current NOXR Summary Value Record. YearToDateTotal)
Tolerance = Lookup Tolerance from Cross-Check Table "Quarterly Emissions Tolerances" where
Parameter = "NOXR" AND
UOM = "LBMMBTU"
if (ABS(Annual NOXR Calculated Value - Current NOXR Summary Value Record. YearToDatcTotal) >
Tolerance)
return result D
// if no result
if {Current NOXR Summary Value Record. O/o ne Seaso nTo DateTota 1 is not null)
return result F
else
If {Expected Summary Value NOx Rate Array for this location == false AND Annual NOXR Calculated Value > 0)
return result G
Environmental Protection Agency
Page 192 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
B
C
D
G
H
Usage:
1
Response
The program could not determine year-to-date for [param], because the Op Supp Data
record for this parameter is missing for one or more previous reporting periods. If you
have submitted emissions data for prior quarters, you should be able to retrieve these
records by logging on to the EPA host.
The program could not determine year-to-date for [param], because the Op Supp Data
record for OPHOURS is missing for one or more previous reporting periods. If you
have submitted emissions data for prior quarters, you should be able to retrieve these
records by logging on to the EPA host.
The [fieldname] in the Summary Value record for [param] is missing or invalid.
The YearToDateTotalof [ytdval] in the Summary Value record for [param] is
inconsistent with the recalculated value of [ytdcalc].
The program could not determine year-to-date for [param], because the Op Supp Data
record for HIT is missing for one or more previous reporting periods. If you have
submitted emissions data for prior quarters, you should be able to retrieve these records
by logging on to the EPA host.
You reported OzoneSeasonToDate in the Summary Value record for [param], but this is
not valid for this parameter.
You did not report a Summary Value record to report year-to-date total for [param].
You reported a Summary Value record for NOXR, but this is not appropriate, because
this record is not consistent with the unit program records and monitoring
methodologies in your monitoring plan. You only report a NOXR Summary Value if
the unit belongs to the Acid Rain program.
Process/Category: Emissions Data Evaluation Report Summary Value Evaluation
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 193 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAGG-14
Check Name: Compare Total Heat Input YTD and OS Values
Related Former Checks:
Applicability:
Description:
Validation Tables:
[Quarterly Emissions Tolerances] (Cross Check Table)
Specifications:
Annual HIT Calculated Value = null
OS HIT Calculated Value = null
HI Summary Invalid Fields = null
Imprecise Fields = null
if (Rpt Period HI Calculated Value is not null OR Expected Summary Value HI Array for this location == false)
if (Expected Summary Value HI Array for this location == true)
If {Annual Reporting Requirement == true)
If (Emissions Tolerance Deviators contains "HIT")
Annual HI Calculated Value = Current HI Summary Value Record.Current Reporting Period Total
else
Annual HI Calculated Value = Rpt Period HI Calculated Value
If (OS Reporting Requirement == true)
if (the Quarter of the Current Reporting Period is equal to 2 or 3)
If (Annual Reporting Requirement == true AND the Quarter of the Current Reporting Period is equal to
2)
OS HIT Calculated Value = Rpt Period HI Calculated Accumulator Array for this location -
April HI Calculated Accumulator Array for this location, and round the result to zero decimal
places.
else
If (Emissions Tolerance Deviators contains "HIT")
OS HIT Calculated Value = Current HI Summary Value Record. Current Reporting
Period Total
else
OS HIT Calculated Value = Rpt Period HI Calculated Value
else if (Quarter of the Current Reporting Period is equal to 4)
OS HIT Calculated Value = 0
If (Annual Reporting Requirement == true AND the Quarter of the Current Reporting Period is greater than 1)
Annual HI Calculated Value = 0
If (OS Reporting Requirement == true AND the Quarter of the Current Reporting Period is greater than 2)
OS HIT Calculated Value = 0
If (the Quarter of the Current Reporting Period is greater than 2 OR (Annual Reporting Requirement == true AND the Quarter of
the Current Reporting Period is equal to 2))
If (Heat Input Start Quarter is not null)
For each quarter in the current year from the Heat Input Start Quarter to the quarter prior to the quarter of the
Current Reporting Period:
else
Environmental Protection Agency
Page 194 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
If this quarter is equal to 2 AND OS Reporting Requirement == true,
Locate an Op Supp Data record for the location and quarter where ParameterCode = "HITOS".
If not found,
if (Expected Summary Value HI Array for this location == true)
set Annual HIT Calculated Value to null,
set OS HIT Calculated Value to null
return result A
otherwise,
Locate an Op Supp Data record for the location and quarter where
ParameterCode = "HIT".
If found,
set Annual HIT Calculated Value to null,
set OS HIT Calculated Value to null
return result A
Otherwise,
add OpValue to OS HIT Calculated Value.
If this quarter is not equal to 2 OR Annual Reporting Requirement == true,
Locate an Op Supp Data record for the location and quarter where ParameterCode = "HIT".
If not found,
if (Expected Summary Value HI Array for this location == true)
set Annual HIT Calculated Value to null,
set OS HIT Calculated Value to null
return result B
Otherwise,
if Annual Reporting Requirement == true
add OpValue to Annual HIT Calculated Value
if this quarter is equal to 3 AND OS Reporting Requirement == true
add OpValue to OS HIT Calculated Value.
else
set Annual HIT Calculated Value to null
set Annual OS HIT Calculated Value to null
if {Current HI Summary Value Record is not null)
If (OS HIT Calculated Value is null AND Annual HIT Calculated Value is null AND Expected Summary Value HI
Array for this location == false and (LME HI Method <> "LTFF" or location does not start with "CP") )
return result K
Otherwise,
If (Current HI Summary Value Record. YcarToDatcTotal is null and Annual Reporting Requirement == true)
OR (Current HI Summary Value Record. Y carToDatcT otal is less than 0,
append "YearToDateTotal" to HIT Summary Invalid Fields
If (Current HI Summary Value Record. O/o lie Seaso nTo DatcTota 1 is null and OS Reporting Requirement == true
AND Quarter of the Current Reporting Period is equal to 2 or 3 or 4), OR Current HI Summary Value
Record. O zo ne Sea so nTo Da teTo ta 1 is less than 0,
append "OzoneSeasonToDateTotal" to HIT Summary Invalid Fields
Environmental Protection Agency
Page 195 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
If {Current HI Summary Value Record. YearToDateTotal is not rounded to zero decimal places)
append "YearToDateTotal" to Imprecise Fields
If {Current HI Summary Value 7?ecor Current HI
Summary Value Record. YearToDateTotal)
append "YearToDateTotal" to HIT Summary Invalid Fields
if {OS HIT Calculated Value is not null AND OS HIT Calculated Value <> Current HI Summary Value
Record. OzoneSeasonToDateTotal)
If {Legacy Data Evaluation == false)
if (ABS(YAV HIT Calculated Value - Current HI Summary Value
Record. Ozo neSeaso 11T0 DateTota 1) > Tolerance OR the quarter of the Current Reporting
Period is greater than 2)
append "OzoneSeasonToDateTotal" to HIT Summary Invalid Fields
else
if (ABS(YAV HIT Calculated Value - Current HI Summary Value
Record.OzoncScasonToDatcTota 1 rounded to the nearest integer) > Tolerance OR the
quarter of the Current Reporting Period is greater than 2)
append "OzoneSeasonToDateTotal" to HIT Summary Invalid Fields
If {HIT Summary Invalid Fields is not null)
If {HIT Summary Invalid Fields contains "Year")
If {HIT Summary Invalid Fields contains "Ozone")
return result D
else
return result H
else
If {Legacy Data Evaluation == true)
return result F
else
return result I
// if no result
if {OS Reporting Requirement == false and Current HI Summary Value Record. OzoneSeasonToDateTotal is not
null)
return result G
Environmental Protection Agency
Page 196 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
else
else if {Annual Reporting Requirement == false and Current HI Summary Value Record. YcarToDatcTotal is not
null)
return result L
If (Expected Summary Value HI Array for this location == false AND {Annual HIT Calculated Value > 0 OR OS HIT
Calculated Value > 0))
return result J
Results:
Result
A
B
C
D
E
F
G
H
I
J
K
Response
The program could not determine ozone-season-to-date totals for [osparam], because
the Op Supp Data record for this parameter is missing for one or more previous
reporting periods. If you have submitted emissions data for prior quarters, you should
be able to retrieve these records by logging on to the EPA host.
The program could not determine year-to-date for [param], because the Op Supp Data
record for this parameter is missing for one or more previous reporting periods. If you
have submitted emissions data for prior quarters, you should be able to retrieve these
records by logging on to the EPA host.
The [fieldname] in the Summary Value record for [param] is missing or invalid.
The YearToDateTotalof [ytdval] in the Summary Value record for [param] is
inconsistent with the recalculated value of [ytdcalc], and the OzoneSeasonToDateTotal
cf [osval] in the Summary Value record for [param] is inconsistent with the recalculated
value of [oscalc].
You reported [fieldname] in the [type] record for [param] that is not rounded to the
appropriate precision for that parameter.
The OzoneSeasonToDateTotal of [osval] in the Summary Value record for [param] is
inconsistent with the recalculated value of [oscalc].
You reported OzoneSeasonToDate in the Summary Value record for [param], but this is
not valid for locations that are not associated with an ozone-season program.
The YearToDateTotalof [ytdval] in the Summary Value record for [param] is
inconsistent with the recalculated value of [ytdcalc].
The OzoneSeasonToDateTotal of [osval] in the Summary Value record for [param] is
inconsistent with the recalculated value of [oscalc].
You did not report a Summary Value record to report year-to-date total for [param].
You reported a Summary Value record for [param], but there was no [param] method
defined in your monitoring plan that was active during the year.
You reported YearToDate in the Summary Value record for [param], but this is not
valid for locations that only report during the ozone season.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Informational Message
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1
Process/Category: Emissions Data Evaluation Report Summary Value Evaluation
Environmental Protection Agency
Page 197 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAGG-15
Check Name:
Compare Operating Time YTD and OS Values
Related Former Checks:
Applicability:
Description:
Validation Tables:
[Quarterly Emissions Tolerances] (Cross Check Table)
Specifications:
Annual OPTIME Calculated Value = null
OS OPTIME Calculated Value = null
OPTIME Summary Invalid Fields = null
Imprecise Fields = null
if {Rpt Period Op Time Calculated Value is not null)
If Annual Reporting Requirement == true
If (Emissions Tolerance Deviators contains "OPTIME")
Annual OPTIME Calculated Value = Current Op Time Summary Value Record. Current Reporting Period Total
Annual OPTIME Calculated Value = Rpt Period Op Time Calculated Value
If OS Reporting Requirement == true)
if (the Quarter of the Current Reporting Period is equal to 2 or 3)
If Annual Reporting Requirement == true AND the Quarter of the Current Reporting Period is equal to 2,
OS OPTIME Calculated Value = Rpt Period Op Time Accumulator Array for this location - April Op
Time Accumulator Array fortius location.
If (Emissions Tolerance Deviators contains "OPTIME")
OS OPTIME Calculated Value = Current Op Time Summary Value Record. Current Reporting
Period Total
else
OS OPTIME Calculated Value = Rpt Period Op Time Calculated Value
else if (Quarter of the Current Reporting Period is equal to 4)
OS OPTIME Calculated Value = 0
If (the Quarter of the Current Reporting Period is greater than 2 OR (Annual Reporting Requirement == true AND the Quarter of
the Current Reporting Period is equal to 2))
If (Start Quarter is not null)
For each quarter in the current year from the Start Quarter to the quarter prior to the quarter of the Current
Reporting Period:
If this quarter is equal to 2 AND OS Reporting Requirement == true
Locate an Op Supp Data record for the location and quarter where ParameterCode = "OSTIME".
else
else
If not found,
set Annual OPTIME Calculated Value to null,
set OS OPTIME Calculated Value to null
Locate the Facility record for the location.
If the First ECMPS Reporting Period in the retrieved record is not null AND is on or
before the 2nd quarter of the current year,
Environmental Protection Agency
Page 198 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
return result A.
exit for.
Otherwise,
add OpValue to OS OPTIME Calculated Value.
If this quarter is not equal to 2 OR Annual Reporting Requirement == true,
Locate an Op Supp Data record for the location and quarter where ParameterCode = "OPTIME".
If not found,
if Annual Reporting Requirement == true
set Annual OPTIME Calculated Value to null.
if OS Reporting Requirement == true
set OS OPTIME Calculated Value to null.
Locate the Facility record for the location.
If the First ECMPS Reporting Period in the retrieved record is not null AND is on or
before the Start Quarter of the current year,
return result B.
exit for.
Otherwise,
if Annual Reporting Requirement == true
add OpValue to Annual OPTIME Calculated Value
if this quarter is equal to 3 AND OS Reporting Requirement == true
add OpValue to OS OPTIME Calculated Value.
Otherwise,
set Annual OPTIME Calculated Value to null,
set OS OPTIME Calculated Value to null.
if (Current Op Time Summary Value Record is not null)
If (Current Op Time Summary Value Record. YearToDateTotal is null and Annual Reporting Requirement == true) OR
0Current Op Time Summary Value Record. YearToDateTotal is less than 0,
append "YearToDateTotal" to OPTIME Summary Invalid Fields
If (CurrentOp Time Summary Value 7?ecor
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
else if (Annual OPTIME Calculated Value is not null OR OS OPTIME Calculated Value is not null)
Tolerance = Lookup Tolerance from Cross-Check Table "Quarterly Emissions Tolerances" where
Parameter = "OPTIME" AND
UOM = "HR"
if (Annual OPTIME Calculated Value is not null AND Annual OPTIME Calculated Value <> Current Op Time
Summary Value Record.YearToDateTotal)
append "YearToDateTotal" to OPTIME Summary Invalid Fields
if (OS OPTIME Calculated Value is not null AND OS OPTIME Calculated Value <> Current Op Time
Summary Value /?6'cwy/. Ozone Sea so nT oDatcT otal)
if (ABS(YAV OPTIME Calculated Value - Current Op Time Summary Value
Record. Ozo ne Seaso 11T0 Da teTo ta 1) > Tolerance OR quarter of the Current Reporting Period is greater
than 2)
append "OzoneSeasonToDateTotal" to OPTIME Summary Invalid Fields
If OPTIME Summary Invalid Fields is not null,
If (OPTIME Summary Invalid Fields contains "Year")
If (OPTIME Summary Invalid Fields contains "Ozone")
return result D
else
return result G
else
return result H
// if no result
if (OS Reporting Requirement == false and Current Op Time Summary Value /?6'cwy/. Ozone Sea so nT oDatcT otal is not
null)
return result F
else if (Annual Reporting Requirement == false and Current Op Time Summary Value Record. YearToDateTotal is not
null)
return result I
Environmental Protection Agency
Page 200 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
B
C
D
E
F
G
H
I
Usage:
1
Response
The program could not determine ozone-season-to-date totals for [osparam], because
the Op Supp Data record for this parameter is missing for one or more previous
reporting periods. If you have submitted emissions data for prior quarters, you should
be able to retrieve these records by logging on to the EPA host.
The program could not determine year-to-date for [param], because the Op Supp Data
record for this parameter is missing for one or more previous reporting periods. If you
have submitted emissions data for prior quarters, you should be able to retrieve these
records by logging on to the EPA host.
The [fieldname] in the Summary Value record for [param] is missing or invalid.
The YearToDateTotalof [ytdval] in the Summary Value record for [param] is
inconsistent with the recalculated value of [ytdcalc], and the Ozone SeasonToDateTotal
cf [osval] in the Summary Value record for [param] is inconsistent with the recalculated
value of [oscalc].
You reported [fieldname] in the [type] record for [param] that is not rounded to the
appropriate precision for that parameter.
You reported OzoneSeasonToDate in the Summary Value record for [param], but this is
not valid for locations that are not associated with an ozone-season program.
The YearToDateTotalof [ytdval] in the Summary Value record for [param] is
inconsistent with the recalculated value of [ytdcalc].
TheOzoneSeasonToDateTotalof [osval] in the Summary Value record for [param] is
inconsistent with the recalculated value of [oscalc].
You reported YearToDate in the Summary Value record for [param], but this is not
valid for locations that only report during the ozone season.
Process/Category: Emissions Data Evaluation Report Summary Value Evaluation
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 201 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAGG-16
Check Name: Compare Operating Hours YTD and OS Values
Related Former Checks:
Applicability:
Description:
Validation Tables:
[Quarterly Emissions Tolerances] (Cross Check Table)
Specifications:
Annual OPHOURS Calculated Value = null
OS OPHOURS Calculated Value = null
OPHOURS Summary Invalid Fields = null
Imprecise Fields = null
if {Rpt Period Op Hours Calculated Value is not null)
If Annual Reporting Requirement == true
If (Emissions Tolerance Deviators contains "OPHOURS")
Annual OPHOURS Calculated Value = Current Op Hours Summary Value Record.Current Reporting Period
Total
else
Annual OPHOURS Calculated Value = Rpt Period Op Hours Calculated Value
If OS Reporting Requirement == true)
if (the Quarter of the Current Reporting Period is equal to 2 or 3)
If Annual Reporting Requirement == true AND the Quarter of the Current Reporting Period is equal to 2,
OS OPHOURS Calculated Value = Rpt Period Op Hours Accumulator Array for this location - April
Op Hours Accumulator Array for this location.
else
If (Emissions Tolerance Deviators contains "OPHOURS")
OS OPHOURS Calculated Value = Current Op Hours Summary Value Record.Current
Reporting Period Total
else
OS OPHOURS Calculated Value = Rpt Period Op Hours Calculated Value
else if (Quarter of the Current Reporting Period is equal to 4)
OS OPHOURS Calculated Value = 0
If (the Quarter of the Current Reporting Period is greater than 2 OR (Annual Reporting Requirement == true AND the Quarter of
the Current Reporting Period is equal to 2))
If (Start Quarter is not null)
For each quarter in the current year from the Start Quarter to the quarter prior to the quarter of the Current
Reporting Period:
If this quarter is equal to 2 AND OS Reporting Requirement == true,
Locate an Op Supp Data record for the location and quarter where ParameterCode =
"OSHOURS" and FuelCd is null.
If not found,
set Annual OPHOURS Calculated Value to null,
set OS OPHOURS Calculated Value to null
return result A
Otherwise,
Environmental Protection Agency
Page 202 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
add OpValue to OS OPHOURS Calculated Value.
If this quarter is not equal to 2 OR Annual Reporting Requirement == true,
Locate an Op Supp Data record for the location and quarter where ParameterCode =
"OPHOURS" and FuelCd is null.
If not found,
set Annual OPHOURS Calculated Value to null,
set OS OPHOURS Calculated Value to null
return result B
Otherwise,
if Annual Reporting Requirement == true
add OpValue to Annual OPHOURS Calculated Value
if this quarter is equal to 3 AND OS Reporting Requirement == true
add OpValue to OS OPHOURS Calculated Value.
Otherwise,
set Annual OPHOURS Calculated Value to null,
set OS OPHOURS Calculated Value to null.
if (Current Op Hours Summary Value Record is not null)
If (Current Op Hours Summary Value Record. YearToDateTotal is null and Annual Reporting Requirement == true) OR
(iCurrent Op Hours Summary Value Record. YearToDateTotal is less than 0,
append "YearToDateTotal" to OPHOURS Summary Invalid Fields
If (Current Op Hours Summary V(due Record. Ova lie Seaso nTo DateTotal is null and OS Reporting Requirement == true
AND Quarter of the Current Reporting Period is equal to 2 or 3 or 4), OR Current Op Hours Summary Value
Record.OzoneSeasonToDateTota 1 is less than 0,
append "OzoneSeasonToDateTotal" to OPHOURS Summary Invalid Fields
If (Current Op Hours Summary Value Record. YearToDateTotal is not rounded to zero decimal places)
append "YearToDateTotal" to Imprecise Fields
If (Current Op Hours Summary Value Record.OzoneSeasonToDateTotal is not rounded to zero decimal places)
append "OzoneSeasonToDateTotal" to Imprecise Fields
If (OPHOURS Summary Invalid Fields is not null)
return result C
else if (Imprecise Fields is not null)
set OPHOURS Summary Invalid Fields to Imprecise Fields
return result E
else if (.Annual OPHOURS Calculated Value is not null OR OS OPHOURS Calculated Value is not null)
Tolerance = Lookup Tolerance from Cross-Check Table "Quarterly Emissions Tolerances" where
Parameter = "OPHOURS" AND
UOM = "HR"
if (Annual OPHOURS Calculated Value is not null AND Annual OPHOURS Calculated Value o Current Op
Hours Summary Value Record.YearToDateTotal)
append "YearToDateTotal" to OPTIME Summary Invalid Fields
if (OS OPHOURS Calculated Value is not null AND OS OPHOURS Calculated Value <> Current Op Hours
Environmental Protection Agency
Page 203 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Summary Value /?6'cwy/. Ozone Sea so nT oDatcT otal)
if (ABS(YAV OPHOURS Calculated Value - Current Op Hours Summary Value
Record. Ozo nc Scaso nTo Da tcTo ta 1) > Tolerance OR quarter of the Current Reporting Period is greater
than 2)
append "OzoneSeasonToDateTotal" to OPHOURS Summary Invalid Fields
If OPHOURS Summary Invalid Fields is not null,
If (OPHOURS Summary Invalid Fields contains "Year")
If (OPHOURS Summary Invalid Fields contains "Ozone")
return result D
else
return result G
else
return result H
// if no result
if (OS Reporting Requirement == false and Current Op Hours Summary Value Record.O/oncScasoiiT oDatcT otal is not
null)
return result F
else if {Annual Reporting Requirement == false and Current Op Hours Summary V(due Record. Yca rTo DateTotal is not
null)
return result I
Environmental Protection Agency
Page 204 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
B
C
D
E
F
G
H
I
Usage:
1
Response
The program could not determine ozone-season-to-date totals for [osparam], because
the Op Supp Data record for this parameter is missing for one or more previous
reporting periods. If you have submitted emissions data for prior quarters, you should
be able to retrieve these records by logging on to the EPA host.
The program could not determine year-to-date for [param], because the Op Supp Data
record for this parameter is missing for one or more previous reporting periods. If you
have submitted emissions data for prior quarters, you should be able to retrieve these
records by logging on to the EPA host.
The [fieldname] in the Summary Value record for [param] is missing or invalid.
The YearToDateTotalof [ytdval] in the Summary Value record for [param] is
inconsistent with the recalculated value of [ytdcalc], and the Ozone SeasonToDateTotal
cf [osval] in the Summary Value record for [param] is inconsistent with the recalculated
value of [oscalc].
You reported [fieldname] in the [type] record for [param] that is not rounded to the
appropriate precision for that parameter.
You reported OzoneSeasonToDate in the Summary Value record for [param], but this is
not valid for locations that are not associated with an ozone-season program.
The YearToDateTotalof [ytdval] in the Summary Value record for [param] is
inconsistent with the recalculated value of [ytdcalc].
TheOzoneSeasonToDateTotalof [osval] in the Summary Value record for [param] is
inconsistent with the recalculated value of [oscalc].
You reported YearToDate in the Summary Value record for [param], but this is not
valid for locations that only report during the ozone season.
Process/Category: Emissions Data Evaluation Report Summary Value Evaluation
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 205 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAGG-17
Check Name: Check BC02 Summary Value
Related Former Checks:
Applicability:
Description:
Specifications:
Current BC02 Summary Value Record = Summary Value record at this location where
Parameter = "BC02" AND
Reporting Period ID = Current Reporting Period
Set RGGIBegin Date, RGGI Start Quarter, AND BC02 Quarterly Reported Value to null.
if (Current BC02 Summary Value Record is not null)
if (CurrentMonitorPlanLocationRecord. StackPipelD is not null)
return result A
Locate a Program record for the unit where the ProgramCode == "RGGI", the UnitMonitorCertBeginDate is on or prior to
the last day of the reporting period, and the EndDate is null or is on or after the first day of reporting period.
If not found,
return result B
else
Set RGGI Begin Date to the later of the UnitMonitorCertBeginDate and the EmissionsRecordingBeginDate (if not
null) in the retrieved record.
If RGGI Begin Date is in a year prior to the current reporting period,
Set RGGI Start Quarter to 1
else
Set RGGI Start Quarter to the quarter of the RGGI Begin Date.
if (Current BC02 Summary Value Record. Current Reporting Period Total < 0)
return result C
else if (Current BC02 Summary Value Record. Currcnt Reporting Period Total is not rounded to one decimal
place)
return result D
else
BC02 Quarterly Reported Value = Current BC02 Summary Valu e Record. C u rrc nt Reporting Period
Total
Environmental Protection Agency
Page 206 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
Response
Severity
A
You reported a Summary Value record for [param], but this value should only be
reported at the unit, not at a stack or pipe.
Critical Error Level 1
B
You reported a Summary Value record for BC02, but this location does not belong to
the RGGI program during this reporting period.
Critical Error Level 1
C
The CurrentReportingPeriodTotal reported in the Summary Value record for [param] is
invalid. The value must be greater than or equal to 0.
Critical Error Level 1
D
You reported [fieldname] in the [type] record for [param] that is not rounded to the
appropriate precision for that parameter.
Critical Error Level 1
E
This check result is obsolete.
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Summary Value Evaluation
Environmental Protection Agency
Page 207 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAGG-18
Check Name: Compare BC02 Mass YTD Values
Related Former Checks:
Applicability:
Description:
Validation Tables:
[Quarterly Emissions Tolerances] (Cross Check Table)
Specifications:
Set AnnualBC02 Calculated Value to null.
If (BC02 Quarterly Reported Value is not null)
AnnualBC02M Calculated Value = BC02 Quarterly Reported Value
else
AnnualBC02M Calculated Value = -1
If (RGGI Start Quarter is not null AND Quarter of the Current Reporting Period is greater than 1)
For each quarter in the current year from the RGGI Start Quarter to the quarter prior to the quarter of the Current Reporting
Period:
Locate an Op Supp Data record for the location and quarter where ParameterCode = "BC02".
If not found,
If (BC02 Quarterly Reported Value is not null)
set AnnualBC02 Calculated Value to null
return result A
Otherwise,
If {AnnualBC02M Calculated Value == -1)
Set AnnualBC02M Calculated Value to OpValue
else
add OpValue to AnnualBC02 Calculated Value.
If (Current BC02 Summary Value Record is not null)
If (AnnualBC02M Calculated Value = -1)
set AnnualBC02 Calculated Value to null
return result G
else if (Current BC02 Summary Value Record. YearToDateTotal is null or is less than 0)
return result B
else if (Current BC02 Summary Value Record. Yca rTo DatcTota 1 is not rounded to one decimal place)
return result C
else if (AnnualBC02 Calculated Value is not null)
if (AnnualBC02 Calculated Value <> Current BC02 Summary Value 7te£w
Tolerance)
Environmental Protection Agency
Page 208 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
return result D
// If no result
If {Current BC02 Summary Value Record.O/.oneSeaso 11ToDatcTota 1 is not null)
return result E.
else
If (AnnualBC02 Calculated Value == -1)
set AnnualBC02 Calculated Value to null
If (AnnualBC02 Calculated Value > 0)
return result F
Results:
Result
A
B
C
D
E
F
G
Response
The program could not determine year-to-date for [param], because the Op Supp Data
record for this parameter is missing for one or more previous reporting periods. If you
have submitted emissions data for prior quarters, you should be able to retrieve these
records by logging on to the EPA host.
The [fieldname] in the Summary Value record for [param] is missing or invalid.
You reported [fieldname] in the [type] record for [param] that is not rounded to the
appropriate precision for that parameter.
The YearToDateTotalof [ytdval] in the Summary Value record for [param] is
inconsistent with the recalculated value of [ytdcalc].
You reported OzoneSeasonToDate in the Summary Value record for [param], but this is
not valid for this parameter.
You did not report a Summary Value record to report year-to-date total for [param].
You reported a Summary Value record for [param], but there was no [param] method
defined in your monitoring plan that was active during the year.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1
Process/Category: Emissions Data Evaluation Report Summary Value Evaluation
Environmental Protection Agency
Page 209 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Category:
Hourly Appendix D
Environmental Protection Agency
Page 210 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAD-1
Check Name: Initialize Accumulators for Appendix D Calculations
Related Former Checks:
Applicability:
Description:
Specifications:
HIApp D Accumulator = 0
SO2 App D Accumulator = 0
CO 2 App D Accumulator = 0
NOXR App E Accumulator = 0
Current Fuel Flow Record = null
Current Fuel Group = null
Fuels Used List = null
Results:
Result Response
Usage:
1 Process/Category:
Severity
Emissions Data Evaluation Report Appendix D/E Unit-Level Initialization
Environmental Protection Agency
Page 211 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAD-3
Check Name:
Initialize Fuel Flow Record
Related Former Checks:
Applicability:
Description:
Specifications:
Current Fuel Group = Current Fuel Flow Record.Fuel Group Cd
if (Current Fuel Flow Record.UmtFuelCd in set {OGS, PRG,OOL})
Special Fuel Burned = true
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Environmental Protection Agency
Page 212 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAD-4
Check Name: Check Fuel Usage Time
Related Former Checks:
Applicability:
Description:
Specifications:
HFF Usage Time Status = true
If (Current Fuel Flow Record.FuelUsageTims is null OR Current Fuel Flow Record.FuelUsageTims < 0 OR Current Fuel Flow
Record. F uc 1U sagcTi mc > 1)
HFF Usage Time Status = false
return result A
else if (Current Hourly Op Record.Opc rat i ngTi me > 0 AND Current Hourly Op Record. OperatingTime <= 1)
if Current Fuel Flow Record.FuelCode is not in Fuels Used List
add 1 to Fuel Op Hours Accumulator Array for the location and fuel
append FuelCode to the Fuels Used List
if (Current Fuel Flow Record.FuelUsageTime > Current Hourly Op Record.OperatingTime)
HFF Usage Time Status = false
return result B
else if (Hourly Fuel Flow Count For Gas + Hourly Fuel Flow Count For Oil == 1 AND (MPPipe Config for Hourly Checks is
null OR Current Hourly Op Record. Lo ca t i o n N a mc begins with "CP") AND Current Fuel Flow Record. F ucl U sagcT i me <>
Current Hourly Op Record.OperatingTime)
HFF Usage Time Status = false
return result B
Results:
Result
A
B
Usage:
1
Response
The FuelUsageTime reported in the HFF record for FuelCode [fueled] is invalid. The
must be greater than 0 and less than or equal to 1.
The FuelUsageTime reported in the HFF record for FuelCode [fueled] is inconsistent
with the OperatingTime for the hour.
Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Severity
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 213 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAD-5
Check Name:
Check Volumetric SODC Code
Related Former Checks:
Applicability:
Description:
Specifications:
HFF SODC Status = true
If (Current Fuel Flow /?6'cwY/.SourceOfData VoluinetricCode is null)
If (Current Fuel Flow /?6'cwy/. VoluinetricFlow Rate is not null)
HFF SODC Status == false
return result A
If (Current Fuel Flow /?6'cwy/. VoluinetricFlow Rate is null)
HFF SODC Status == false
return result B
else if {Current Fuel Group == "GAS" and Current Fuel Flow /?6'co/Y/.SourccOfDataVolumctricCodc in set {5, 6})
HFF SODC Status == false
return result C
else if (Current Fuel Flow /?6'cwY/.SourccOfDataVoluinctricCodc = "3" AND Current Unit Is Peaking == false)
HFF SODC Status == false
return result D
else if (HFF Fuel Indicator Code is not null)
if (Current Fuel Flow /?6'cwY/.SourceOfData VoluinetricCode == "4" AND HFF Fuel Indicator Code<> "E")
HFF SODC Status == false
return result E
else if (Current Fuel Flow /?6'co/Y/.SourccOfDataVolumctricCodc in set {5, 6} AND HFF Fuel Indicator CodeO "I")
HFF SODC Status == false
else
return result F
Results:
Result
A
Response
You did not report a [fieldname] in the HFF record for FuelCode [fueled], but you
reported a [ratefieldname].
You reported a [fieldname] in the HFF record for FuelCode [fueled], but you did not
report a [ratefieldname].
The SourceOfDataVolumetricCode reported in the HFF record for FuelCode [fueled] is
invalid.
You reported a [fieldname] of 3 in the HFF record for FuelCode [fueled], but,
according to the qualification record in your monitoring plan, this is not a peaking unit.
You reported a [fieldname] of 4 in the HFF record for FuelCode [fueled], which
indicates that the fuel is an emergency fuel, but according to the Unit Fuel record in
your monitoring plan, this fuel is not an emergency fuel.
You reported a [fieldname] of [sodc] in the HFF record for FuelCode [fueled], which
indicates that the fuel is an igniter fuel, but according to the Unit Fuel record in your
monitoring plan, this fuel is not an igniter fuel.
Severity
Critical Error Level 1
B
Critical Error Level 1
C
Critical Error Level 1
D
Critical Error Level 1
E
Critical Error Level 1
F
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Environmental Protection Agency
Page 214 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOUR AD-6
Check Name:
Check Oil Mass SODC Code
Related Former Checks:
Applicability:
Description:
Specifications:
HFF Mass SODC Status == true
If (Current Fuel Flow Record.SourceOfDataMassCode is null)
If (Current Fuel Flow Record.MassFlowRate is not null)
HFF Mass SODC Status == false
return result A
If (Current Fuel Flow Record.MassFlowRate is null)
HFF Mass SODC Status == false
return result B
else if (Current Fuel Flow /?6'cwy/. VoluinetricFlow Rate is not null AND Current Fuel Flow Record. SourceOfDataMassCode <>
"2")
HFF Mass SODC Status == false
return result C
else if (Current Fuel Flow Record.VolumetricFlowRate is null AND Current Fuel Flow Record. SourceOfDataMassCode == "2")
HFF Mass SODC Status == false
return result D
else if (Current Fuel Flow Record. SourceOfDataMassCode = "3" AND Current Unit Is Peaking == false)
HFF Mass SODC Status == false
return result E
else if (HFF Fuel Indicator Code is not null)
if (Current Fuel Flow Record. SourceOfDataMassCode == "4" AND HFF Fuel Indicator Code <> "E")
HFF Mass SODC Status == false
return result F
else if (Current Fuel Flow Record. SourceOfDataMassCode in set {5, 6} AND HFF Fuel Indicator CodeO "I")
HFF Mass SODC Status == false
return result G
else
Results:
Result
A
Response
You did not report a [fieldname] in the HFF record for FuelCode [fueled], but you
reported a [ratefieldname].
You reported a [fieldname] in the HFF record for FuelCode [fueled], but you did not
report a [ratefieldname].
You reported a SourceOfDataMassCode of [sodc] in the HFF record for FuelCode
[fueled], but you also reported a VolumetricFlowRate. The SourceOfDataMassCode
must be 2 when mass oil flow is calculated from volumetric oil flow.
You reported a SourceOfDataMassCode of 2 in the HFF record for FuelCode [fueled],
but you did not report a VolumetricFlowRate. The SourceOfDataMassCode should be
2 only when the mass oil rate is calculated from volumetric oil flow.
You reported a [fieldname] of 3 in the HFF record for FuelCode [fueled], but,
according to the qualification record in your monitoring plan, this is not a peaking unit.
You reported a [fieldname] of 4 in the HFF record for FuelCode [fueled], which
indicates that the fuel is an emergency fuel, but according to the Unit Fuel record in
your monitoring plan, this fuel is not an emergency fuel.
You reported a [fieldname] of [sodc] in the HFF record for FuelCode [fueled], which
indicates that the fuel is an igniter fuel, but according to the Unit Fuel record in your
monitoring plan, this fuel is not an igniter fuel.
Severity
Critical Error Level 1
B
Critical Error Level 1
C
Critical Error Level 1
D
Critical Error Level 1
E
Critical Error Level 1
F
Critical Error Level 1
G
Critical Error Level 1
Environmental Protection Agency
Page 215 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
Usage:
1 Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Environmental Protection Agency
Page 216 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAD-7
Check Name: Check Fuel Flow Monitoring System
Related Former Checks:
Applicability:
Description:
Specifications:
HFF System Type = null
FuelFlowComponentRecords = null
CurrentAppendixDStatus = null
f (Current Fuel Flow /?6'ew "GAS")
return result E
else if (Current Fuel Group == "OIL" AND Current Mon ,SV.v Record. SystemTypeCode not in set {OILV, OILM})
return result F
else if (Current Fuel Group == "OIL" AND Current Oil Fuel Flow Record.SourceOfDataMassCode == "2" AND
Current Mon ,SV.v Record. SystemTypeCode <> "OILV")
return result G
else
HFF System Type = Current Mon Sys Record. SystemTypeCode
if Current Mon Sys Record. FuelCode is not null and is not equal to Current Fuel Flow Record .Vuc\Co Ac
HFF System Fuel = Current Mon Sys Record FvlqXCo&q
return result H
else if (Current Fuel Flow Record. SourceOfDataVolumetricCode in set (0,9} OR (Current Fuel Group ==
"OIL" AND Current Fuel Flow Record. SourceOfDataMassCode in set {0,9}))
if (Current Fuel Group = "OIL")
Locate MonitorSystemComponentRecordsByHourLocation where the SystemID is equal to
CurrentFuelFlowRecord. SystemID and the ComponentTypeCd = "OFFM" or "BOFF"
Environmental Protection Agency
Page 217 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
For each retrieved record found:
If (MonitorSystemComponentRecordsByHourLocation. ComponentTypeCd ==
"OFFM")
Add the MonitorSystemComponentRecordsByHourLocation record to
FuelFlowComponentRecords.
If none were found,
return result I.
else if {Current Fuel Group = "GAS")
Locate MonitorSystemComponentRecordsByHourLocation where the SystemID is equal to
CurrentFuelFlowRecord.SystemID and the ComponentTypeCd = "GFFM" or "BGFF"
For each retrieved record found:
If (MonitorSystemComponentRecordsByHourLocation.ComponentTypeCd ==
"GFFM")
Add the MonitorSystemComponentRecordsByHourLocation record to
FuelFlowComponentRecords.
If none were found,
return result I.
Environmental Protection Agency
Page 218 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
B
C
D
E
F
G
H
Usage:
1
Response
You reported a SourceOfDataVolumetricCode or SourceOfDataMassCode in the HFF
record for FuelCode [fueled], indicating the use of a fuel flowmeter system, but you did
not report its MonitoringSystemlD.
You reported a SourceOfDataVolumetricCode or SourceOfDataMassCode in the HFF
record for FuelCode [fueled] that indicates the use of substitute data, but you did not
report a MonitoringSystemlD. This was not required for legacy EDR data, but for
ECMPS, you should report the primary MonitoringSystemlD of the fuel flowmeter
system that normally records the flow for this fuel.
You reported a SourceOfDataVolumetricCode or SourceOfDataMassCode in the HFF
record for FuelCode [fueled] that indicates the use of an emergency or igniter fuel, so
you should not have reported a MonitoringSystemlD in this record.
You reported MonitoringSystemlD [ID] in the HFF record for FuelCode [fueled], but
there is no MonitorSystem record for this system in your monitoring plan that was
active during the hour.
You reported MonitoringSystemlD [ID] in the HFF record for FuelCode [fueled], but
this system is not a GAS monitoring system.
You reported MonitoringSystemlD [ID] in the HFF record for FuelCode [fueled], but
this system is not an OILM or OILV monitoring system.
You reported a SourceOfDataMassCode of 2 in the HFF record for FuelCode [fueled],
indicating that you are calculating mass oil rate from volumetric oil flow, but
MonitoringSystemlD [ID] is not an OILV monitoring system.
Your reported MonitoringSystemlD [ID] in the HFF record for FuelCode [fueled], but
the FuelCode for this system in the MonitorSystem record is [sysfuel]. The FuelCode
in the Monitor System record should be the same as the FuelCode in the HFF record.
You did not report any active fuel flowmeter components in your monitoring plan for
MonitoringSystemlD [ID], The QA status for Appendix D testing for this system will
not be evaluated.
Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 219 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAD-8
Check Name:
Check Volumetric Units of Measure
Related Former Checks:
Applicability:
Description:
Specifications:
HFF UOM Status = true
If (Current Fuel Flow /fec-wrf. VolumetricUnitsOfMeasureCode is null)
If (Current Fuel Flow /?6'cwy/. VoluinetricFlow Rate is not null)
HFF UOM Status = false
return result A
If (Current Fuel Flow /?6'cwy/. VoluinetricFlow Rate is null)
HFF UOM Status = false
return result B
else if (Current Fuel Group == "OIL" AND Current Fuel Flow Record. VolumctricUnitsOnvicasurcCodc is not in set {"GALHR",
"BBLHR", "M3HR", "SCFH"})
HFF UOM Status = false
return result C
else if (Current Fuel Group == "GAS" AND Current Fuel Flow Record. VolumetricUnitsOfMeasureCode <> "HSCF")
HFF UOM Status = false
return result C
else
Results:
Result
A
Response
You did not report a [fieldname] in the HFF record for FuelCode [fueled], but you
reported a [ratefieldname].
You reported a [fieldname] in the HFF record for FuelCode [fueled], but you did not
report a [ratefieldname].
The VolumetricUnitsOfMeasureCode reported in the HFF record for FuelCode [fueled]
is invalid.
Severity
Critical Error Level 1
B
Critical Error Level 1
C
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Environmental Protection Agency
Page 220 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAD-9
Check Name:
Check Fuel in HFF Record
Related Former Checks:
Applicability:
Description:
Specifications:
HFF Fuel Indicator Code = null
Locate active UnitFuel record for the location
where FuelCd = Current Fuel Flow Record.UmtFuelCd
If found,
HFF Fuel Indicator Code = Current Fuel Flow Record. I ndicatorCd
else
return result A
Results:
Result
A
You did not report an active Unit Fuel record for FuelCode [fueled] in your monitoring Critical Error Level 1
plan.
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Environmental Protection Agency
Page 221 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAD-10
Check Name: Check Volumetric Flow in HFF Record
Related Former Checks:
Applicability:
Description:
Specifications:
HFF Calc Volumetric Rate = null
HFF Max Heat Input for Volume = null
If (HFF System Type is not null AND HFF SOD Status == true AND HFF Mass SODC Status == true AND HFF UOM Status == true)
If (Current Fuel Flow /?6'cwy/. VoluinetricFlow Rate is null)
If (HFF System Type<> "OILM")
return result A
else
If (HFF System Type== "OILM")
return result B
else if (Current Fuel Flow Record. SourceOfDataVolumetricCode == "4")
If (Current Entity Type is equal to "Unit")
Locate a Unit Capacity record for the location and hour.
If exactly one record is found, and the MaximumHourlyHeatlnputCapacity in the retrieved record is
greater than 0,
HFF Max Heat Input for Volume =
t/wifCa/7ac%Bj//
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
if (Count <> 1)
return result C
else if (Defcm It Record. D c fa ill t V a 1 lie <= 0)
return result D
else if (Default /tecwc/.DcfaultUnitsOnVIcasiircCodc == Current Fuel Flow
Record. Vo 1 u l lie t ri c U n i t sO HVI e a s u re C o de)
HFF Calc Volumetric Rate = Default Record .DefaultValue
If (Current Fuel Flow VolumetricFlowRate <= 0)
return result E
else if (Current Fuel Flow Record. VolumctricFlowRatc <> HFF Calc Volumetric Rate)
return result F
else
If (Current Fuel Flow VolumetricFlowRate <= 0)
return result E
else
return result G
else if Current Fuel Flow Ttecon/.MonitoringSy stemID is not null)
If (Current Fuel Flow VolumetricFlowRate <= 0)
return result E
else
If (Current Fuel Flow Record. SourceOfDataVolumstricCode <> 3)
HFF Calc Volumetric Rate = Current Fuel Flow Record. VolumetricFlowRate
Count active System Fuel Flow Record for the system.
If (Count o 1)
return result H
else if (System Fuel Flow i?ecorHFF Calc Volumetric Rate)
return result J
else
If (HFF Calc Volumetric Rate > System Fuel Flow itecordMaximumFuelFlowRate
return result K
else
return result L
else
If (Current Fuel Flow Record VolumetricFlowRate <= 0)
return result E
else
HFF Calc Volumetric Rate = Current Fuel Flow Record. VolumetricFlowRate
Environmental Protection Agency
Page 223 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
A
B
C
D
E
F
H
I
J
K
M
Usage:
1
Response
You did not report a VolumetricFlowRate in the HFF record for FuelCode [fueled],
which is required when using [systype] MonitoringSystemID [ID],
You reported a VolumetricFlowRate in the HFF record for FuelCode [fueled], which is
invalid when using an OILM system.
You did not report one and only one default record for [parameter] for FuelCode
[fueled] in your monitoring plan that was active during current hour.
The DefaultValue reported in the active [parameter] default record for the hour is
invalid.
The VolumetricFlowRate reported in the HFF record for FuelCode [fueled] is invalid.
You reported a SourceOfDataVolumetricCode of [sodc] in the HFF record for
FuelCode [fueled], but the VolumetricFlowRate is not equal to the fuel flow rate
defined in the active [parameter] default record in your monitoring plan.
The VolumetricUnitsOfMeasureCode in the HFF record for FuelCode [fueled] is not
the same as the DefaultUnitsOfMeasureCode in the active [parameter] default record in
your monitoring plan.
You did not report one and only one active SystemFuelFlow record for
MonitoringSystemID [ID] in your monitoring plan for the hour.
The MaximumFuelFlowRate reported in the active System Fuel Flow record for
MonitoringSystemID [ID] in your monitoring plan is invalid.
You reported a SourceOfDataVolumetricCode of 3 in the HFF record for FuelCode
[fueled], but the VolumetricFlowRate is not equal to the MaximumFuelFlowRate
specified in the active System Fuel Flow record for MonitoringSystemID [ID] in your
monitoring plan.
Warning: The VolumetricFlowRate reported in the HFF record for FuelCode [fueled]
exceeds the MaximumFuelFlowRate specified in the active System Fuel Flow record
for MonitoringSystemID [ID] in your monitoring plan. Sources are required to
periodically (at least once annually) evaluate the appropriateness of these maximum
values in the monitoring plan and make proper adjustments when necessary. You
should investigate the cause of these exceedances and determine whether an adjustment
to your monitoring systems or monitoring plan is necessary.
The VolumetricUnitsOfMeasureCode in the HFF record for FuelCode [fueled] is not
the same as the SystemFuelFlowUOMCode in the active System Fuel Flow record for
MonitoringSystemID [ID] in your monitoring plan.
You did not report one and only one valid active Unit Capacity record in your
monitoring plan for the unit for the hour.
Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Informational Message
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 224 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAD-11
Check Name: Check Mass Oil Flow in HFF Record
Related Former Checks:
Applicability:
Description:
Specifications:
HFF Calc Mass Oil Rate = null
HFF Max Heat Input for Mass = null
If (HFF System Type is not null AND HFF SOD Status == true AND HFF Mass SODC Status == true AND HFF UOM Status == true)
If (Current Fuel Flow Record.MassFlowRate is null)
If (HFF System Type== "OILM")
return result A
Else if (HFFSystem Type== "OILV"
If (Current Fuel Flow Record. SourceOfDataMassCode == "2")
return result B
Else if (Current Unit isARP == true)
return result C
else
If (HFF System Type== "GAS")
return result D
else if (HFF System Type == "OILV")
If (Current Fuel Flow Record. SourceOfDataMassCode == "2" AND Current Fuel Flow Record.MassFlowRate
<=0)
return result E
else if (Current Fuel Flow Record. SourceOfDataMassCode == "4")
If (Current Entity Type is equal to "Unit")
Locate a Unit Capacity record for the location and hour.
If exactly one record is found, and the MaximumHourlyHeatlnputCapacity in the retrieved record is
greater than 0,
HFF Max Heat Input for Mass =
UnitCapacityByHourLocation. MaximumHourlyHeatlnputCapacity
If (HFFGCV is not null)
HFF Calc Mass Oil Rate = HFF Max Heat Input for Mass / HFFGCV * 1000000,
rounded to one decimal place.
else
return result M
else
If (Current Fuel Flow Record. MassFlowRatc <= 0)
return result E
else
HFF Calc Mass Oil Rate = Current Fuel Flow Record.MassFlowRate
else if (Current Fuel Flow Record. SourceOfDataMassCode == "9")
HFF Mass Oil Default Parameter = "MNOF"
Count active Default Record for the location where
ParameterCode == HFF Mass Oil Default Parameter
FuelCode == Current Fuel Flow Record.¥uc\CoAc
if (Count <> 1)
return result F
else if (Defau It Record. D c fan 11V a 1 lie <= 0 OR Default Record DefauVAJmtsOfM&asmeCoAe <> "LBHR")
Environmental Protection Agency
Page 225 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
return result G
HFF CalcMass Oil Rate = Default Record. DefaultValue
If (Current Fuel Flow Record. MassFlowRatc <= 0)
return result E
else if (Current Fuel Flow Record. MassFlow Ratc <> HFF Calc Mass Oil Rate)
return result H
else if (Current Fuel Flow RecordMomtoxmgSystevaSD is not null)
If (Current Fuel Flow Record.MassFlowRate <= 0)
return result E
else
If (Current Fuel Flow Record. SourceOfDataMassCode <> 3)
HFF CalcMass Oil Rate = Current Fuel Flow Record. MassFlowRate
Count active System Fuel Flow Record for the system.
If (Count o 1)
return result I
else if (System Fuel Flow itecordMaximumFuelFlowRate <= 0 OR System Fuel Flow
itecor "LBHR")
return result J
else
If (Current Fuel Flow Record. SourceOfDataMassCode == 3)
HFF Calc Mass Oil Rate = System Fuel Flow itecordMaximumFuelFlowRate
If (Current Fuel Flow Record. MassFlowRate <> HFF Calc Mass Oil Rate)
return result K
else
If (HFF CalcMass Oil Rate > System Fuel Flow Recor dMaximumFuelFlowRate
return result L
else
If (Current Fuel Flow Record.MassFlowRate <= 0)
return result E
else
HFF Calc Mass Oil Rate = Current Fuel Flow Record .MassFlowRate
Environmental Protection Agency
Page 226 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
A
B
C
D
E
F
G
H
I
J
K
M
Usage:
1
Response
You did not report a [fieldname] in the HFF record for FuelCode [fueled], but the
MonitoringSystemID [ID] is an [systype] fuel flow system.
You reported a SourceOfDataMassCode of 2 in the HFF record for FuelCode [fueled],
which indicates that the mass oil rate was calculated from the volumetric oil rate, but
you did not report a MassFlowRate in the record.
You did not report a [fieldname] in the HFF record for FuelCode [fueled], but this value
is required for an ARP unit.
You reported a MassFlowRate in the HFF record for FuelCode [fueled]. This value
should be blank for a gas fuel.
The MassFlowRate reported in the HFF record for FuelCode [fueled] is invalid.
You did not report one and only one default record for [parameter] for FuelCode
[fueled] in your monitoring plan that was active during current hour.
The DefaultValue or DefaultUnitsOfMeasureCode reported in the active [parameter]
default record for the hour is invalid.
You reported a SourceOfDataMassCode of [sodc] in the HFF record for FuelCode
[fueled], but the MassFlowRate is not equal to the fuel flow rate defined in the active
[parameter] default record in your monitoring plan.
You did not report one and only one active SystemFuelFlow record for
MonitoringSystemID [ID] in your monitoring plan for the hour.
The MaximumFuelFlowRate or SystemFuelFlowUOMCode reported in the active
System Fuel Flow record for MonitoringSystemID [ID] in your monitoring plan is
invalid.
You reported a SourceOfDataMassCode of 3 in the HFF record for FuelCode [fueled],
but the MassFlowRate is not equal to the MaximumFuelFlowRate specified in the
active System Fuel Flow record for MonitoringSystemID [ID] in your monitoring plan.
Warning: The MassFlowRate reported in the HFF record for FuelCode [fueled] exceeds
the MaximumFuelFlowRate specified in the active System Fuel Flow record for
MonitoringSystemID [ID] in your monitoring plan. Sources are required to periodically
(at least once annually) evaluate the appropriateness of these maximum values in the
monitoring plan and make proper adjustments when necessary. You should investigate
the cause of these exceedances and determine whether an adjustment to your
monitoring systems or monitoring plan is necessary.
You did not report one and only one valid active Unit Capacity record in your
monitoring plan for the unit for the hour.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Informational Message
Critical Error Level 1
Process/Category: Emissions Data Evaluation Report ¦
¦ Hourly Fuel Flow
Environmental Protection Agency
Page 227 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAD-12
Check Name: Determine Density
Related Former Checks:
Applicability:
Description:
Validation Tables:
Fuel Type Reality Checks for Density (Cross Check Table)
Fuel Type Warning Levels for Density (Cross Check Table)
Table D-6 Missing Data Values (Cross Check Table)
Specifications:
HFF Density = null
Current Density Record = null
Count the HourlyParamFuelFlow record where
HourlyParamFuelFlow.HourlyFuelFlowID = Current Fuel Flow /?6'cwy/.Hourly FuclFlow ID AND
HourlyParamFuelFlow.ParameterCode = "DENSOIL"
If (Count >1)
return result A
Else If (Count == 0)
If (HFF System Type== "OILV" and Current Fuel Flow Record. SourceOfDataMassCode == "2")
return result B
Else if {HFF System Type= "OILV" AND Current Fuel Flow Record. SourceOfDataMassCode == "2")
Current Density Record = matching record
Density UOM = Current Density Record. Para mete rUOMCode
if (Density UOM not in set {LBGAL, LBBBL, LBM3, LBSCF})
return result C
else if (Current Fuel Flow Record VolumetricUnitsOfMeasureCode
return result D
else if (Current Fuel Flow Record VolumetricUnitsOfMeasureCode
return result D
else if (Current Fuel Flow Record VolumetricUnitsOfMeasureCode
return result D
else if (Current Fuel Flow Record VolumetricUnitsOfMeasureCode
return result D
else if (Current Density Record.ParamValFuel > 0)
Density Default = null
If (Current Density Record. SampleTypeCode == 8)
Density Default = Lookup "MissingDataValue" in "Table D-6 Missing Data Values"
where "Parameter" column = "DENSOIL -" + Density UOM AND "FuelCode" column = Current Fuel
Flow Record .FuelCode
If (Density Default == null)
Max Expected Density = Lookup "Upper Value" in "Fuel Type Warning Levels for Density Cross Check Table"
where "Fuel Code - Units Of Measure" column = concatenation of (Current Fuel Flow Record.FuelCode,
" -", Density UOM)
Min Expected Density = Lookup "Lower Value" in "Fuel Type Warning Levels for Density Cross Check Table"
where "Fuel Code - Units Of Measure" column = concatenation of (Current Fuel Flow Record.FuelCode,
" -", Density UOM)
Max Allowed Density = Lookup "Upper Value" in "Fuel Type Reality Checks for Density Cross Check Table"
where "Fuel Code - Units Of Measure" column = concatenation of (Current Fuel Flow Record.FuelCode,
" -", Density UOM)
== "GALHR" AND Density UOM <> "LBGAL")
== "BBLHR" AND Density UOM <> "LBBBL")
== "M3HR" AND Density UOM <> "LBM3")
== "SCFH" AND Density UOM <> "LBSCF")
Environmental Protection Agency
Page 228 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Min Allowed Density = Lookup "Lower Value" in "Fuel Type Reality Checks for Density Cross Check Table"
where "Fuel Code - Units Of Measure" column = concatenation of (Current Fuel Flow Record.FuelCode,
" -", Density UOM)
if (Max Allowed Density is not null AND Current Density /?6'eMY/.ParamValFucl > \ lax. I Uowed Density) OR
(Min Allowed Density is not null AND Current Density Record. Param ValFucl < Min Allowed Density)
return result E
else
HFFDensity = Current Density Record. Pa ram Va 1Fuc 1
if (Min Expected Density is not null AND HFF Density < Min Expected Density) OR (Max Expected
Density is not null AND HFF Density > Max Expected Density)
return result F
else
if (Density Default == Current Density Record.ParamValFuel)
HFF Density = Current Density Record. Pa ra m Va 1Fuc 1
else
return result G
else
return result H
else
return result I
Results:
Result
A
B
C
D
E
F
G
H
I
Response
You reported more than one HPFF record for [parameter] for FuelCode [fueled] for the
hour.
You did not report an HPFF record for [parameter] for FuelCode [fueled] for the hour.
The ParameterUOMCode reported in the HPFF record for DENSOIL for FuelCode
[fueled] is missing or invalid.
The ParameterUOMCode reported in the HPFF record for DENSOIL for FuelCode
[fueled] is inconsistent with the VolumetricUnitsOfMeasureCode reported in the
associated HFF record.
The ParameterValueForFuel reported in the HPFF record for [parameter] for FuelCode
[fueled] is outside the range of allowable values for the fuel type.
The ParameterValueForFuel reported in the HPFF record for [parameter] for FuelCode
[fueled] is outside the range of expected values for the fuel type.
You reported a SampleTypeCode of 8 in the HPFF record for [parameter] for FuelCode
[fueled], indicating the use of a Table D-6 default, but the ParameterValueForFuel does
not equal the default value for the fuel.
The ParameterValueForFuel reported in the HPFF record for [parameter] for FuelCode
[fueled] is invalid. The value should be greater than 0.
You reported an HPFF record for [parameter] for FuelCode [fueled], but this value is
only appropriate when using an OILV system and a SourceOfDataMassCode equal to 2.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 2
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1
Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Environmental Protection Agency
Page 229 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAD-13
Check Name:
Check Density Sample Type
Related Former Checks:
Applicability:
Description:
Specifications:
If {Current Density Record is not null)
If Current Density Record. SampleTypeCode not in {1, 2, 5, 6, 7, 8}
return result A
Results:
Result
A
Response
The SampleTypeCode reported in the HPFF record for DENSOIL for FuelCode
[fueled] is missing or invalid.
Severity
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Environmental Protection Agency
Page 230 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAD-14
Check Name:
Check Extraneous Density Record Fields
Related Former Checks:
Applicability:
Description:
Specifications:
Hourly Extraneous Fields = null
If {Current Density Record is not null)
If (Current Density Record. F o rm u 1 a I dc n t i fi c r is not null)
append "Formulaldentifier" to Hourly Extraneous Fields
If (Current Density Record Momio ri ngSy stc m ID is not null)
append "MonitoringSystemID" to Hourly Extraneous Fields
If {Current Density . ScgmcntNumbc r is not null)
append "SegmentNumber" to Hourly Extraneous Fields
If (Current Density Record.OpcratingConditionCodc is not null)
append "OperatingConditionCode" to Hourly Extraneous Fields
If {Hourly Extraneous Fields is not null)
return result A
Results:
Result
A
Response
You reported [fieldnames] in the HPFF record for DENSOIL for FuelCode [fueled].
This data should be blank.
Severity
Non-Critical Error
Usage:
1 Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Environmental Protection Agency
Page 231 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAD-15
Check Name:
Calculate Mass Oil Flow
Related Former Checks:
Applicability:
Description:
Validation Tables:
Hourly Emissions Tolerances (Cross Check Table)
Specifications:
IfHFF Calc Volumetric Flow is not null AND HFFDensity is not null)
HFF Calc Mass Oil Flow = HFF Density * HFF Calc Volumetric Flow, and round the result to one decimal place (0.1)
Flow Rate Tolerance = Lookup Tolerance from Cross-Check Table "Hourly Emissions Tolerances" where
Parameter = "OILM" AND
UOM = "LBHR"
If (Current Fuel Flow Record.MassFlowRate > 0)
if (ABS(Current Fuel Flow Record.MassFlowRate - HFF Calc Mass Oil Flow) > Flow Rate Tolerance)
return result A
Results:
Result
A
Response
The MassFlowRate reported in the HFF record for FuelCode [fueled] is inconsistent
with the value calculated from the VolumetricFlowRate and density.
Severity
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Environmental Protection Agency
Page 232 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAD-16
Check Name: Determine GCV
Related Former Checks:
Applicability:
Description:
Validation Tables:
Fuel Type Reality Checks for GCV (Cross Check Table)
Fuel Type Warning Levels for GCV (Cross Check Table)
Table D-6 Missing Data Values (Cross Check Table)
Specifications:
HFFGCV= null
Current GCV Record = null
Count the HourlyParamFuelFlow record where
HourlyParamFuelFlow.HourlyFuelFlowID = Current Fuel Flow /?6'cwy/.Hourly FuclFlow ID AND
HourlyParamFuelFlow.ParameterCode = "GCV"
If (Count >1)
return result A
Else If (Count == 0)
If (Current HI HPFF Record is not null)
return result B
Else if (Current HI HPFF Record is not null)
Current GCV Record = matching record
GCV UOM = Current GCV Record. Pa ra llie te rU OIVICode
if (GCV UOM not in set {BTUGAL, BTUBBL, BTUM3, BTUSCF, BTULB, BTUHSCF}
return result C
else if (Current Fuel Group == "GAS" AND GCV UOM <> "BTUHSCF")
return result D
else if (Current Fuel Group == "OIL" AND Current Fuel Flow Record.MassFlowRate is not null AND GCV UOM <>
"BTULB")
return result D
else if (Current Fuel Group == "OIL" AND Current Fuel Flow Ttecon/.MassFlowRate is null AND Current Fuel Flow
Record. Vo 1 ulliet ricU ni tsOHVIeasureCode == "GALHR" AND GCV UOM <> "BTUGAL")
return result D
else if (Current Fuel Group == "OIL" AND Current Fuel Flow Ttecon/.MassFlowRate is null AND Current Fuel Flow
Record. Vo 1 u me t ri c U n i t s O fM ea s u re C ode == "BBLHR" AND GCV UOM <> "BTUBBL")
return result D
else if (Current Fuel Group == "OIL" AND Current Fuel Flow Ttecon/.MassFlowRate is null AND Current Fuel Flow
Record. Vo 1 u me t ri c U n i t s O fM ea s u re C o de == "M3HR" AND GCV UOM <> "BTUM3")
return result D
else if (Current Fuel Group == "OIL" AND Current Fuel Flow 7?ecor "BTUSCF")
return result D
else if (Current GCV Record. P a ra m Va 1F uc 1 > 0)
GCV Default = null
If (Current GCV Record. SampleT\ pcCode == 8)
GCV Default = Lookup "MissingDataValue" in "Table D-6 Missing Data Values"
where "Parameter" column = "GCV -" + GCV UOM AND "FuelCode" column = Current Fuel Flow
Record. FuclCodc
If (GCVDefault == null)
GCV Default = Lookup "MissingDataValue" in "Table D-6 Missing Data Values"
Environmental Protection Agency
Page 233 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
where "Parameter" column = "GCV -" + GCV UOM and FuelCode column is null.
If (GCVDefault == null)
Max Expected GCV = Lookup "Upper Value" in "Fuel Type Warning Levels for GCV Cross Check Table"
where "Fuel Code - Units Of Measure" column = concatenation of (Current Fuel Flow Record.FuelCode,
" -GCV UOM)
Min Expected GCV = Lookup "Lower Value" in "Fuel Type Warning Levels for GCV Cross Check Table"
where "Fuel Code - Units Of Measure" column = concatenation of (Current Fuel Flow Record.FuelCode,
" -GCV UOM)
Max Allowed GCV = Lookup "Upper Value" in "Fuel Type Reality Checks for GCV Cross Check Table"
where "Fuel Code - Units Of Measure" column = concatenation of (Current Fuel Flow Record .Vuc\Co Ac.
" -GCV UOM)
Min Allowed GCV = Lookup "Lower Value" in "Fuel Type Reality Checks for GCV Cross Check Table"
where "Fuel Code - Units Of Measure" column = concatenation of (Current Fuel Flow Record .Vuc\Co Ac.
" -GCV UOM)
if (MaxAllowed GCV is not null AND Current GCVRecord.ParamValFucl >MaxAllowed GCV) OR (Min
Allowed GCV is not null AND Current GC V Record. Pa rain Va 1Flie 1 < Min Allowed GCV)
return result E
else if (Current GCV Record. Pa ra m Va 1Flie 1 is not rounded to one decimal place)
return result J
else
HFF GCV = Current GCV Record. Param Val Fuel
if (Min Expected GCV is not null AND HFF GCV < Min Expected GCV) OR (Max Expected GCV is not
null AND HFF GCV > Max Expected GCV)
return result F
If (Current GCV Record. Pa ra m Va 1F uc 1 is not rounded to one decimal place)
return result J
else if (GCV Default == Current GCV Record. P a ra m Va 1F uc 1)
HFF GCV = Current GCV Record. Param Val Fuel
else
return result G
else
return result H
else
return result I
Environmental Protection Agency
Page 234 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
A
B
C
D
E
F
G
H
I
J
Usage:
1
Response
You reported more than one HPFF record for [parameter] for FuelCode [fueled] for the
hour.
You did not report a HPFF record for GCV for FuelCode [fueled] for the hour.
The ParameterUOMCode reported in the HPFF record for GCV for FuelCode [fueled]
is missing or invalid.
The ParameterUOMCode reported in the HPFF record for GCV for FuelCode [fueled]
is inconsistent with the fuel flow units of measure.
The ParameterValueForFuel reported in the HPFF record for [parameter] for FuelCode
[fueled] is outside the range of allowable values for the fuel type.
The ParameterValueForFuel reported in the HPFF record for [parameter] for FuelCode
[fueled] is outside the range of expected values for the fuel type.
You reported a SampleTypeCode of 8 in the HPFF record for [parameter] for FuelCode
[fueled], indicating the use of a Table D-6 default, but the ParameterValueForFuel does
not equal the default value for the fuel.
The ParameterValueForFuel reported in the HPFF record for GCV for FuelCode
[fueled] is invalid. The value must be greater than 0.
You reported an HPFF record for GCV for FuelCode [fueled], but you have not
reported an HPFF record for HI for the hour.
You reported [fieldname] in the [type] record for [param] that is not rounded to the
appropriate precision for that parameter.
Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Non-Critical Error
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 235 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAD-17
Check Name:
Check GCV Sample Type
Related Former Checks:
Applicability:
Description:
Specifications:
If (Current GCV Record is not null)
If (Current Fuel Group == "OIL" AND Current G C V Record .Sample T\ pc C ode not in {1, 2, 5, 6, 7, 8})
return result A
else if (Current Fuel Group == "GAS" AND Current GCV Record .Sample T\ pc C ode not in {0, 2, 3, 4, 6, 7, 8})
return result A
Results:
Result
A
Response
The SampleTypeCode reported in the HPFF record for GCV for FuelCode [fueled] is
missing or invalid.
Severity
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Environmental Protection Agency
Page 236 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAD-18
Check Name:
Check Extraneous GCV Record Fields
Related Former Checks:
Applicability:
Description:
Specifications:
Hourly Extraneous Fields = null
If (Current GCV Record is not null)
If (Current GCVTtecon/.Formulaldentifier is not null)
append "Formulaldentifier" to Hourly Extraneous Fields
If (Current GCV Recordri ngSy stcmID is not null)
append "MonitoringSystemID" to Hourly Extraneous Fields
If (Current GCVTtecwrf.SegmentNumber is not null)
append "SegmentNumber" to Hourly Extraneous Fields
If (Current GCV Record.Opc rat i ngCo ndi tio nCodc is not null)
append "OperatingConditionCode" to Hourly Extraneous Fields
If (Hourly Extraneous Fields is not null)
return result A
Results:
Result
A
Response
You reported [fieldnames] in the HPFF record for GCV for FuelCode [fueled]. This
data should be blank.
Severity
Non-Critical Error
Usage:
1 Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Environmental Protection Agency
Page 237 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAD-19
Check Name: Validate Heat Input Record
Related Former Checks:
Applicability:
Description:
Specifications:
Current HI HPFF Record = null
Count the HourlyParamFuelFlow record where
HourlyParamFuelFlow.HourlyFuelFlowID = Current Fuel Flow Hourly FuclFlow ID AND
HourlyParamFuelFlow.ParameterCode = "HI"
If (Count >1)
HIApp D Accumulator = -1
return result A
Else If (Count == 0)
If (Heat Input App D Method Active For Hour == true)
HIApp D Accumulator = -1
return result B
Else if (Heat Input App D Method Active For Hour == true)
Current HI HPFF Record = matching record
if (Current HI HPFF . Mo ni to ri ngFo rmu 1 a Id is null
return result C
else
Cur HIMon Formula Record = Lookup active formula in MonitoringFormula Table where
MonitoringFormulalD = Current HI HPFF . Mo n i to ri ng Fo rmu 1 a ID
if (Cur HIMon Formula Record is null)
return result D
else if (Cur HIMon Formula Record.ParameterCode <> "HI")
return result E
else if (Current Fuel Group == "GAS")
If (Cur HIMon Formula Record. EquationCodc not in set {D-6, F-20})
return result F
else if (Current Fuel Flow Ttecon/.MassFlowRate is not null)
If (Cur HIMon Formula .RecordEquationCode not in set {D-8, F-19})
return result F
else
If {Cur HIMon Formula Record.EquationCode <> "F-19V")
return result F
else
return result G
Environmental Protection Agency
Page 238 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
A
B
C
D
E
F
G
Usage:
1
Response
You reported more than one HPFF record for [parameter] for FuelCode [fueled] for the
hour.
You did not report an HPFF record for [parameter] for FuelCode [fueled] for the hour.
You did not report a FormulalD in the HPFF record for HI for FuelCode [fueled].
You reported FormulalD [ID] in the HPFF record for HI for FuelCode [fueled], but
there is no active Formula record for this formula in your monitoring plan.
You reported FormulalD [ID] in the HPFF record for HI for FuelCode [fueled], but this
is not an HI formula.
The FormulaCode of FormulalD [ID] reported in the HPFF record for HI for FuelCode
[fueled] is invalid.
You reported an HPFF record for GCV for FuelCode [fueled], but you have not
reported an HPFF record for HI for the hour.
Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 239 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAD-20
Check Name:
Check Extraneous Heat Input Record Fields
Related Former Checks:
Applicability:
Description:
Specifications:
Hourly Extraneous Fields = null
If (Current HI HPFF Record is not null)
If (Current HI HPFF Record Momio ri ngSy stc m ID is not null)
append "MonitoringSystemID" to Hourly Extraneous Fields
If (Current HI HPFF Record. Seg 1 lie nt N u 1 libe r is not null)
append "SegmentNumber" to Hourly Extraneous Fields
If (Current HI HPFF Record. O pc ra t i ngCo ndi t i o nCode is not null)
append "OperatingConditionCode" to Hourly Extraneous Fields
If (Current HI HPFF Record. SampleTypeCode is not null)
append "SampleTypeCode" to Hourly Extraneous Fields
If (Hourly Extraneous Fields is not null)
return result A
Results:
Result
A
You reported [fieldnames] in the HPFF record for HI for FuelCode [fueled]. This data Non-Critical Error
should be blank.
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Environmental Protection Agency
Page 240 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAD-21
Check Name: Calculate Heat Input Rate
Related Former Checks:
Applicability:
Description:
Validation Tables:
Hourly Emissions Tolerances (Cross Check Table)
Specifications:
HFF Calc HI Rate = null
If {Current HI HPFF Record is not null)
if (Current Fuel Flow Record.SourceOfDataVohimstricCode== "4")
if (HFF Max Heat Input for Volume is not null)
HFF Calc HI Rate = HFF Max Heat Input for Volume
else
HIApp D Accumulator = -1
return result A
else if {Current Fuel Flow Record. SourceOfDataMassCode == "4")
if (HFF Max Heat Input for Mass is not null)
HFF Calc HI Rate = HFF Max Heat Input for Mass
else
HIApp D Accumulator = -1
return result A
else if (HFF GCV is not null)
HI HPFF Tolerance = Lookup Tolerance from Cross-Check Table "Hourly Emissions Tolerances" where
Parameter = "HI HPFF" AND
UOM = "MMBTUHR"
If (HFF System Type== "GAS" OR Current Fuel Flow Record.MassFlowRate is null)
If (HFF Calc Volumetric Rate is not null)
HFF Calc HI Rate = HFF Calc Volumetric Rate * HFF GCV /1000000, and round the result to one
decimal place.
else
HI App D Accumulator = -1
return result A
else
if (HFF Calc Mass Oil Rate is not null)
HFF Calc HI Rate = HFF Calc Mass Oil Rate * HFF GCV / 1000000, and round the result to one
decimal place.
else
HI App D Accumulator = -1
return result A
If (HFF Calc HI Rate is not null)
If Current Fuel Flow Record.FuelUsageTime > 0 AND Current Fuel Flow Record.FuelUsageTime <= 1 AND HI App D
Accumulator >= 0)
// Note - this accumulates totals for all Fuel flow records and does not work like a normal parameter
HIApp D Accumulator = HIApp D Accumulator + HFF Calc HI Rate * Current Fuel Flow
Record. F uc 1U sagcTi mc
Environmental Protection Agency
Page 241 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
else
HIApp D Accumulator = -1
If (Current HI HPFF Record. ParamVaWuel > 0)
If (Current Fuel Flow Record.SowLceOfDataYolumetncCode == "4" OR Current Fuel Flow
Ttecon/.SourceOfDataMassCode == "4")
/ (HFF Calc HI Rate is equal to Current HI HPFF Record. Param Va 1Flie 1)
if (Current Fuel Flow /?6'cwY/.SourccOfDataVoluinctricCodc == "4")
If (Current Fuel Flow /?6'cwy/. VoluinctricFlow Rate is greater than 0, AND
HFF Calc Volumetric Rate is not equal to Current Fuel Flow
Record. VolumetricFlowRate)
Flow Tolerance = Lookup Tolerance from Cross-Check Table "Hourly
Emissions Tolerances" where Parameter = "FOIL"
if (ABS(HFF Calc Volumetric Rate - Current Fuel Flow
Record. VolumetricFlowRate) > Flow Tolerance)
return result C
else
If (Current Fuel Flow Record.MassFlowRate is greater than 0, AND
HFF Calc Mass Oil Rate is not equal to Current Fuel Flow Ttecon/.MassFlowRate)
Flow Tolerance = Lookup Tolerance from Cross-Check Table "Hourly
Emissions Tolerances" where Parameter = "FOIL"
if (ABS(HFF Calc Mass Oil Rate - Current Fuel Flow Record.MassFlowRate)
> Flow Tolerance)
return result D
else
If (ABS (HFF Calc HI Rate - Current HI HPFF Record. P a ra m Va 1F lie 1) > HI HPFF Tolerance)
return result B
else
HIApp D Accumulator = -1
return result A
Results:
Result
A
B
C
D
Response
The ParameterValueForFuel in the HPFF record for [parameter] for FuelCode [fueled]
could not be recalculated due to errors listed above.
The ParameterValueForFuel reported in the HPFF record for HI for FuelCode [fueled]
is inconsistent with the recalculated value.
You reported a SourceOfDataVolumetricCode of 4, indicating that you burned an
emergency fuel, but the VolumetricFlowRate in the HFF record for FuelCode [fueled]
is inconsistent with the maximum fuel flow rate for the unit. When you burn an
emergency fuel, you should report the maximum fuel flow rate, which is based on the
maximum hourly heat input capacity of the unit.
You reported a SourceOfDataMassCode of 4, indicating that you burned an emergency
fuel, but the MassFlowRate in the HFF record for FuelCode [fueled] is inconsistent
with the maximum fuel flow rate for the unit. When you burn an emergency fuel, you
should report the maximum fuel flow rate, which is based on the maximum hourly heat
input capacity of the unit.
Severity
Informational Message
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 242 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
Usage:
1 Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Environmental Protection Agency
Page 243 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAD-22
Check Name:
Check Reported Heat Input
Related Former Checks:
Applicability:
Description:
Specifications:
If (Current HI HPFF Record is not null)
If (Current HI HPFF Record. Pa ra m Va 1Fuc 1 >= 0
If (Current HI HPFF Record. Pa ra m Va 1Fuc 1 is not rounded to one decimal place)
return result D
else if (Current Fuel Flow Record. SourceOfDataVolumetricCode == "4" and HFF Max Heat Input for Volume is not
null)
if (Current HI HPFF Record. Pa ram Va 1F lie 1 is not equal to HFF Max Heat Input for Volume)
return result E
else if (Current Fuel Flow Record.SourceOfDataMassCode == "4" and HFF Max Heat Input for Mass is not null)
if (Current HI HPFF Record. Pa ra m Va 1F lie 1 is not equal to HFF Max Heat Inputfor Mass)
return result F
else
If Current Entity Type == "CP",
Count active UnitCapacity record for each unit linked to the pipe
if (Count <> 1 for any unit)
return result A
else
Calculate Max Heat Input as the sum of Unit Capacity
itecordMaximumHourlyHeatlnputCapacity for all units.
Count active UnitCapacity record for the associated unit,
if (Count <> 1)
return result A
else
Max Heat Input = Unit Capac/Yy.Recorii.MaximumHourlyHeatlnputCapacity
if Current HI HPFF Record. ParamValFuel > Unit CapacityRecor(i.MaximumHourlyHeatlnputCapacity
return result B
else
else
return result C
Environmental Protection Agency
Page 244 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
A
B
C
D
E
Usage:
1
Response
You did not report one and only one active Unit Capacity record in your monitoring
plan for the unit (or for each unit linked to the pipe) for the hour.
Warning: The ParameterValueForFuel reported in the HPFF record for HI for FuelCode
[fueled] exceeds the MaximumHourlyHeatlnputCapacity reported in the Unit Capacity
record in your monitoring plan. Sources are required to periodically (at least once
annually) evaluate the appropriateness of maximum values in the monitoring plan and
make proper adjustments when necessary. You should investigate the cause of these
exceedances and determine whether an adjustment to the
MaximumHourlyHeatlnputCapacity reported in your monitoring plan is necessary.
The ParameterValueForFuel reported in the HPFF record for HI for FuelCode [fueled]
is invalid. The value must be greater than or equal to 0.
You reported [fieldname] in the [type] record for [param] that is not rounded to the
appropriate precision for that parameter.
You reported a SourceOfDataVolumetricCode of 4 in the HFF record, indicating that
you burned an emergency fuel. However, you did not report the maximum hourly heat
input capacity for the unit as the ParameterValueforFuel in the HPFF record for HI,
which is required when you burn an emergency fuel.
You reported a SourceOfDataMassCode of 4 in the HFF record, indicating that you
burned an emergency fuel. However, you did not report the maximum hourly heat
input capacity for the unit as the ParameterValueforFuel in the HPFF record for HI,
which is required when you burn an emergency fuel.
Severity
Critical Error Level 1
Informational Message
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Process/Category: Emissions Data Evaluation Report ¦
¦ Hourly Fuel Flow
Environmental Protection Agency
Page 245 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAD-23
Check Name:
Check Heat Input Units Of Measure
Related Former Checks:
Applicability:
Description:
Specifications:
If (Current HI HPFF Record is not null)
If {Current HI HPFF Record.ParameterUOMCode <> "MMBTUHR")
return result A
Results:
Result
A
Response
The ParameterUOMCode reported in the HPFF record for HI for FuelCode [fueled] is Critical Error Level 1
missing or invalid. The value should be "MMBTUHR".
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Environmental Protection Agency
Page 246 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAD-24
Check Name: Validate S02 Record
Related Former Checks:
Applicability:
Description:
Specifications:
Current S02 HPFFRecord = null
HFF S02 Equation Code = null
Count the HourlyParamFuelFlow record where
HourlyParamFuelFlow.HourlyFuelFlowID = Current Fuel Flow /?6'cwy/.Hourly FuclFlow ID AND
HourlyParamFuelFlow.ParameterCode = "S02"
If (Count >1)
SO2 App D Accumulator = -1
return result A
Else If (Count == 0)
If (S02 App D Method Active For Hour == true)
SO2 App D Accumulator = -1
return result B
Else if (S()2 App D Method Active For Hour == true)
Current S02 HPFF Record = matching record
if (Current S02 HPFF wy/. Mo ni to ri ngFo rmu 1 a Id is null
return result C
else
Cur S02 Mon Formula Record = Lookup active formula in MonitoringFormula Table where
MonitoringFormulalD = Current S02 HPFF Mo ni to ri ngFo rmu 1 a ID
if (Cur S02 Mon Formula Record is null)
return result D
else if (Cur S02 Mon Formula Record.ParameterCode <> "S02")
return result E
else if (Current Fuel Group == "GAS")
If (Cur S02 Mon Formula Record.EquationCode in set {D-4, D-5})
HFF S02 Equation Code = Cur S02 Mon Formula Record. EquationCodc
else
return result F
else
If {Cur S02 Mon Formula Record .EquationCode == "D-2")
HFF S02 Equation Code = Cur S02 Mon Formula Record. Equat io nCodc
else
return result F
else
return result G
Environmental Protection Agency
Page 247 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
A
B
C
D
E
F
G
Usage:
1
Response
You reported more than one HPFF record for [parameter] for FuelCode [fueled] for the
hour.
You did not report an HPFF record for [parameter] for FuelCode [fueled] for the hour.
You did not report a FormulalD in the HPFF record for S02 for FuelCode [fueled].
You reported FormulalD [ID] in the HPFF record for S02 for FuelCode [fueled], but
there is no active Formula record for this formula in your monitoring plan.
You reported FormulalD [ID] in the HPFF record for S02 for FuelCode [fueled], but
this is not an S02 formula.
The FormulaCode of FormulalD [ID] reported in the HPFF record for S02 for
FuelCode [fueled] is invalid.
You reported an HPFF record for S02 for FuelCode [fueled], but you do not have an
active Appendix D S02 method for the hour.
Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 248 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAD-25
Check Name:
Check Extraneous S02 Record Fields
Related Former Checks:
Applicability:
Description:
Specifications:
Hourly Extraneous Fields = null
If (Current S02 HPFFRecord is not null)
If (Current S02 HPFF Record. Mo n i to ri ng Sy stc m ID is not null)
append "MonitoringSystemID" to Hourly Extraneous Fields
If (Current S02 HPFF SegmcntNumbc r is not null)
append "SegmentNumber" to Hourly Extraneous Fields
If (Current S02 HPFF Record.Opc ra t i ngC'o nditio nCodc is not null)
append "OperatingConditionCode" to Hourly Extraneous Fields
If (Current S02 HPFF Record. S a mp 1 cTy pc Code is not null)
append "SampleTypeCode" to Hourly Extraneous Fields
If (Hourly Extraneous Fields is not null)
return result A
Results:
Result
A
Response
You reported [fieldnames] in the HPFF record for S02 for FuelCode [fueled]. This
data should be blank.
Severity
Non-Critical Error
Usage:
1 Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Environmental Protection Agency
Page 249 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAD-26
Check Name:
Check S02 Units Of Measure
Related Former Checks:
Applicability:
Description:
Specifications:
If {Current S02 HPFFRecord is not null)
If (Current S02 HPFF Record. Para 1 lieterUOIVI Code <> "LBHR")
return result A
Results:
Result
A
Response
The ParameterUOMCode reported in the HPFF record for S02 for FuelCode [fueled] is Critical Error Level 1
missing or invalid. The value should be "LBHR".
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Environmental Protection Agency
Page 250 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAD-27
Check Name: Calculate S02 Mass Rate
Related Former Checks:
Applicability:
Description:
Validation Tables:
Hourly Emissions Tolerances (Cross Check Table)
Specifications:
HFF Calc S02 = mill
If {Current S02 HPFFRecord is not null)
if 0Current Fuel Group == "GAS" AND HFFS02 Equation Code == "D-4" AND HFF Sulfur is not null AND HFF Calc
Volumetric Rate is not null
SO 2 HPFF Tolerance = Lookup Tolerance from Cross-Check Table "Hourly Emissions Tolerances" where
Parameter = "S02 Gas HPFF" AND
UOM = "LBHR"
HFF Calc S02 = HFF Sulfur * HFF Calc Volumetric Rate * 2.0 / 7000, and round the result to 5 decimal places.
else if (Current Fuel Group == "GAS" AND HFF S02 Equation Code == "D-5" AND HFF S02 Emission Rate is not null AND
HFF Calc HI Rate is not null
SO 2 HPFF Tolerance = Lookup Tolerance from Cross-Check Table "Hourly Emissions Tolerances" where
Parameter = "S02 Gas HPFF" AND
UOM = "LBHR"
HFF Calc S02 = HFF S02 Emission Rate * HFF Calc HI Rate, and round the result to 5 decimal places.
else if (Current Fuel Group == "OIL" AND HFF Sulfur is not null AND HFF Calc Mass Oil Rate is not null
SO2 HPFF Tolerance = Lookup Tolerance from Cross-Check Table "Hourly Emissions Tolerances" where
Parameter = "S02 Oil HPFF" AND
UOM = "LBHR"
HFF Calc S02 = HFF Sulfur * HFF Calc Mass Oil Rate *2.0/100, and round the result to 1 decimal place,
ff (HFF Calc S02 is not null)
If Current Fuel Flow Record.FuelUsageTime > 0 AND Current Fuel Flow Record.FuelUsageTime <= 1 AND SO2 App
D Accumulator >= 0)
// Note - this accumulates totals for all Fuel flow records and does not work like a normal parameter
SO2 App D Accumulator = S02 App D Accumulator + HFF Calc S02 * Current Fuel Flow
Record .FuelU sageT ime
else
SO2 App D Accumulator = -1
If (Current S02 HPFF Record. Pa rain Va 1F lie 1 >= 0)
if (ABS (HFF Calc S02 - Current S02 HPFF Record.? aramValFuel) > S02 HPFF Tolerance)
return result A
else
SO2 App D Accumulator = -1
return result B
Environmental Protection Agency
Page 251 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result Response Severity
A The ParameterValueForFuel reported in the HPFF record for S02 for FuelCode Critical Error Level 1
[fueled] is inconsistent with the recalculated value.
B The ParameterValueForFuel in the HPFF record for [parameter] for FuelCode [fueled] Informational Message
could not be recalculated due to errors listed above.
Usage:
1 Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Environmental Protection Agency
Page 252 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAD-28
Check Name: Determine Sulfur Content
Related Former Checks:
Applicability:
Description:
Validation Tables:
Fuel Type Reality Checks for Sulfur (Cross Check Table)
Fuel Type Warning Levels for Sulfur (Cross Check Table)
Table D-6 Missing Data Values (Cross Check Table)
Specifications:
HFF Sulfur = null
Current Sulfur Record = null
Count the HourlyParamFuelFlow record where
HourlyParamFuelFlow.HourlyFuelFlowID = Current Fuel Flow RecordRom\y¥nQW\owlT) AND
HourlyParamFuelFlow.ParameterCode = "SULFUR"
If (Count >1)
return result A
Else If (Count == 0)
If (HFF S02 Equation Code in set {D-2, D-4})
return result B
Else if (HFFS02 Equation Code in set {D-2, D-4})
Current Sulfur Record = matching record
Sulfur UOM = Current Sulfur Record. ParamctcrUOMCodc
ff (Current Fuel Group == "GAS" AND Sulfur UOM <> "GRHSCF")
return result C
else if (Current Fuel Group == "OIL" AND Sulfur UOM <> "PCT")
return result C
else if {Current Sulfur Record.ParamValFuel > 0)
Sulfur Default = null
ff (Sulfur UOM == "GRHSCF")
Sulfur Precision = 1
else
Sulfur Precision = 4
If (Current Sulfur Record. SampleTypeCode == 8)
Sulfur Default = Lookup "MissingDataValue" in "Table D-6 Missing Data Values"
where "Parameter" column = "SULFUR" AND "FuelCode" column = Current Fuel Flow
Record .FuelCode
If (Sulfur Default == null)
Max Expected Sulfur = Lookup "Upper Value" in "Fuel Flow Warning Levels for Sulfur Content Cross Check
Table"
where "Fuel Code" column = Current Fuel Flow Record.FuelCode
Min Expected Sulfur = Lookup "Lower Value" in "Fuel Flow Warning Levels for Sulfur Content Cross Check
Table"
where "Fuel Code" column = Current Fuel Flow Record.FuelCode
Max Allowed Sulfur = Lookup "Upper Value" in "Fuel Flow Reality Checks for Sulfur Content Cross Check
Table"
where "Fuel Code" column = Current Fuel Flow Record.FuelCode
Min Allowed Sulfur = Lookup "Lower Value" in "Fuel Flow Reality Checks for Sulfur Content Cross Check
Environmental Protection Agency
Page 253 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Table"
where "Fuel Code" column = Current Fuel Flow Record.FuelCode
If {Max Allowed Sulfur is not null AND Current Sulfur Record.ParamValFuel > Max Allowed Sulfur) OR (Min
Allowed Sulfur is not null AND Current Sulfur Record .ParamValFuel < Min Allowed Sulfur)
return result D
else if {Current Sulfur Record.ParainValFuel is not rounded to Sulfur Precision)
return result I
else
HFF Sulfur = Current Sulfur Record.ParamValFuel
if {Min Expected Sulfur is not null AND HFF Sulfur < Min Expected Sulfur) OR {Max Expected Sulfur is
not null AND HFF Sulfur > Max Expected Sulfur)
return result E
If (Current SuIfur Record. Pa ra inValFuel is not rounded to Sulfur Precision)
return result I
else if Sulfur Default == Current Sulfur Record.ParamValFuel
HFF Sulfur == Current Sulfur Record. Pa ra inValFuel
else
return result F
else
return result G
else
return result H
Results:
Result
A
B
C
D
E
F
G
H
I
Response
You reported more than one HPFF record for [parameter] for FuelCode [fueled] for the
hour.
You reported a formula with a FormulaCode of [code] in the HPFF record for S02 for
FuelCode [fueled], but you did not report an HPFF record for SULFUR. Use of this
formula to calculate S02 requires the reporting of the fuel's sulfur content.
The ParameterUOMCode reported in the HPFF record for SULFUR for FuelCode
[fueled] is missing or invalid.
The ParameterValueForFuel reported in the HPFF record for [parameter] for FuelCode
[fueled] is outside the range of allowable values for the fuel type.
The ParameterValueForFuel reported in the HPFF record for [parameter] for FuelCode
[fueled] is outside the range of expected values for the fuel type.
You reported a SampleTypeCode of 8 in the HPFF record for [parameter] for FuelCode
[fueled], indicating the use of a Table D-6 default, but the ParameterValueForFuel does
not equal the default value for the fuel.
The ParameterValueForFuel reported in the HPFF record for [parameter] for FuelCode
[fueled] is invalid. The value should be greater than 0.
You reported an HPFF record for [parameter] for FuelCode [fueled], but you do not
require this value to calculate S02.
You reported [fieldname] in the [type] record for [param] that is not rounded to the
appropriate precision for that parameter.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 2
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1
Process/Category: Emissions Data Evaluation Report ¦
¦ Hourly Fuel Flow
Environmental Protection Agency
Page 254 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAD-29
Check Name:
Check Extraneous Sulfur Record Fields
Related Former Checks:
Applicability:
Description:
Specifications:
Hourly Extraneous Fields = null
If {Current Sulfur Record is not null)
If (Curren t Su //m/* . Fo rm u 1 a I dc n t i fi c r is not null)
append "Formulaldentifier" to Hourly Extraneous Fields
If (Current Sulfur Record.MomtoringSystemlD is not null)
append "MonitoringSystemID" to Hourly Extraneous Fields
If (Current Sulfur Record. ScgmcntNumbcr is not null)
append "SegmentNumber" to Hourly Extraneous Fields
If (Current Sulfur Record.Opc rat i ngCo ndit io nCodc is not null)
append "OperatingConditionCode" to Hourly Extraneous Fields
If (Hourly Extraneous Fields is not null)
return result A
Results:
Result
A
Response
You reported [fieldnames] in the HPFF record for SULFUR for FuelCode [fueled].
This data should be blank.
Severity
Non-Critical Error
Usage:
1 Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Environmental Protection Agency
Page 255 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAD-30
Check Name:
Check Sulfur Sample Type
Related Former Checks:
Applicability:
Description:
Specifications:
If {Current Sulfur Record is not null)
If (Current Fuel Group == "OIL" AND Current Sulfur Record. SampleTypeCode not in {1, 2, 5, 6, 7, 8})
return result A
else if {Current Fuel Group == "GAS" AND Current Sulfur Record.SampleTypeCode not in {0, 2, 4, 5, 6, 7, 8})
return result A
Results:
Result
A
Response
The SampleTypeCode reported in the HPFF record for SULFUR for FuelCode [fueled] Critical Error Level 1
is missing or invalid.
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Environmental Protection Agency
Page 256 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAD-31
Check Name: Determine S02 Emission Rate
Related Former Checks:
Applicability:
Description:
Specifications:
HFF S02 Emission Rate = null
Current S02R Record = null
Count the HourlyParamFuelFlow record where
HourlyParamFuelFlow.HourlyFuelFlowID = Current Fuel Flow /?6'cwy/.Hourly FuclFlow ID AND
HourlyParamFuelFlow.ParameterCode = "S02R"
If (Count >1)
return result A
Else If (Count == 0)
If (HFF S02 Equation Code== "D-5")
return result B
Else if (HFFS02 Equation Code== "D-5")
Current S02R Record = matching record
If (Current S()2R Record. Pa ramctc rUOIVICode <> "LBMMBTU"}
return result C
else if (Current S()2R Record. Pa rain Va 1Flie 1 > 0)
HFF S02 Emission Rate = Current S()2 R Record. Pa rain Va 1F lie 1
else
return result D
else
return result E
Results:
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
require this value to calculate S02.
Usage:
1 Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Result Response
A You reported more than one HPFF record for [parameter] for FuelCode [fueled] for the
hour.
B You reported a formula with a FormulaCode of "D-5" in the HPFF record for S02 for
FuelCode [fueled], but you did not report an HPFF record for S02R. Use of formula
D-5 to calculate S02 requires the reporting of the S02 emission rate for the fuel.
C The ParameterUOMCode reported in the HPFF record for S02R for FuelCode [fueled]
is missing or invalid. The value should be "LBMMBTU".
D The ParameterValueForFuel reported in the HPFF record for [parameter] for FuelCode
[fueled] is invalid. The value should be greater than 0.
E You reported an HPFF record for [parameter] for FuelCode [fueled], but you do not
Environmental Protection Agency
Page 257 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAD-32
Check Name:
Check Extraneous S02R Record Fields
Related Former Checks:
Applicability:
Description:
Specifications:
Hourly Extraneous Fields = null
If (Current S02R Record is not null)
If (Current .S'02/?/?6'cwY/.MonitoringS\ stcinID is not null)
append "MonitoringSystemID" to Hourly Extraneous Fields
If (Current S()2R Record. ScgmcntNumber is not null)
append "SegmentNumber" to Hourly Extraneous Fields
If (Current S()2R Record .0\~>cn\{\ngConditionCodc is not null)
append "OperatingConditionCode" to Hourly Extraneous Fields
If (Current S02R Record. SampleTypeCode is not null)
append "SampleTypeCode" to Hourly Extraneous Fields
If (Hourly Extraneous Fields is not null)
return result A
Results:
Result
A
Response
You reported [fieldnames] in the HPFF record for S02R for FuelCode [fueled]. This
data should be blank.
Severity
Non-Critical Error
Usage:
1 Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Environmental Protection Agency
Page 258 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAD-33
Check Name: Check S02R Formula
Related Former Checks:
Applicability:
Description:
Specifications:
If {Current S02R Record is not null)
If (Current M2/? Fo rm u 1 a I dc nt i fic r is null)
If {Current Fuel Flow Record. FuelCode <> "PNG" OR Current S()2 R Record. Pa rain Va 1F lie 1 <> 0.0006)
return result A
else
Cur S02R Mon Formula Record = Lookup active formula in MonitoringFormula Table where
MonitoringFormulalD = Current S02R Record. MonitoringFormulalD
if {Cur S02R Mon Formula Record is null)
return result B
else if {Cur S02R Mon Formula Record. ParameterCode <> "S02R"
return result C
else if {Cur S02R Mon Formula Record.EquationCode <> "D-1H")
return result D
Results:
Result
A
B
C
D
Response
You did not report a FormulalD in the HPFF record for S02R for FuelCode [fueled].
This formula is required except when using the standard default emission rate of 0.0006
for pipeline natural gas.
You reported FormulalD [ID] in the HPFF record for S02R for FuelCode [fueled], but
there is no active Formula record for this formula in your monitoring plan.
You reported FormulalD [ID] in the HPFF record for S02R for FuelCode [fueled], but
this is not an S02R formula.
The FormulaCode of FormulalD [ID] reported in the HPFF record for S02R for
FuelCode [fueled] is invalid. The FormulaCode should be "D-1H".
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1
Process/Category: Emissions Data Evaluation Report ¦
¦ Hourly Fuel Flow
Environmental Protection Agency
Page 259 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAD-34
Check Name:
Check Reported S02 Mass Rate
Related Former Checks:
Applicability:
Description:
Specifications:
If {Current S02 HPFFRecord is not null)
If (Current S02 HPFF Record. Pa ra m Va 1Fuc 1 is null or is less than 0
else if (Current Fuel Group == "OIL" AND Current S02 HPFF Record. P a ra m Va 1F uc 1 is not rounded to one decimal place)
return result A
return result B
Results:
Result
A
Response
The ParameterValueForFuel reported in the HPFF record for S02 for FuelCode
[fueled] is invalid. The value must be greater than or equal to 0.
You reported [fieldname] in the [type] record for [param] that is not rounded to the
appropriate precision for that parameter.
Severity
Critical Error Level 1
B
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Environmental Protection Agency
Page 260 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAD-35
Check Name: Determine FC Factor
Related Former Checks:
Applicability:
Description:
Validation Tables:
Fuel Type Reality Checks for FC FACTOR (Cross Check Table)
Specifications:
HFF Fc Factor = null
Current Fc Factor Record = null
Count the HourlyParamFuelFlow record where
HourlyParamFuelFlow.HourlyFuelFlowID = Current Fuel Flow Hourly FuclFlow ID AND
HourlyParamFuelFlow.ParameterCode = "FC"
If (Count >1)
return result A
Else If (Count == 0)
If (Current C02 HPFFRecord is not null)
return result B
Else if (Current C02 HPFF Record is not null)
Current Fc Factor Record = matching record
If (Current Fc Factor /?6'ewY/.ParamctcrUOIVICodc <> "SCFCBTU")
return result C
else if (Current FcFactor Record. Para m Va 1Flie 1 > 0)
if (Current FcFactor Record. Pa ra m Va 1F lie 1 is not rounded to one decimal place)
return result G
else
HFF Fc Factor = Current Fc Factor Record.ParamValFuel
Max Allowed Fc Factor = Lookup "Upper Value" in "Fuel Type Reality Checks for FC Factor Cross Check
Table"
where "FuelType" column = Current Fuel Group
Min Allowed Fc Factor = Lookup "Lower Value" in "Fuel Type Reality Checks for FC Factor Cross Check Table"
where "FuelType" column = Current Fuel Group
If {Max Allowed FcFactor is not null AND Current Fc Factor Record. Pa rain Va 1F lie 1 > Max Allowed Fc Factor)
OR (Min Allowed FcFactor is not null AND Current Fc Factor Record. Pa ra m Va 1Flie 1 < Min Allowed Fc Factor)
return result D
else
return result E
else
return result F
Environmental Protection Agency
Page 261 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
A
B
C
D
E
F
G
Usage:
1
Response
You reported more than one HPFF record for [parameter] for FuelCode [fueled] for the
hour.
You reported an HPFF record for C02 for FuelCode [fueled], but you did not report an
HPFF record for FC for the hour.
The ParameterUOMCode reported in the HPFF record for FC for FuelCode [fueled] is
missing or invalid.
The ParameterValueForFuel reported in the HPFF record for [parameter] for FuelCode
[fueled] is outside the range of allowable values for the fuel type.
The ParameterValueForFuel reported in the HPFF record for FC for FuelCode [fueled]
is invalid.
You reported an HPFF record for FC for FuelCode [fueled], but you have not reported
an HPFF record for C02 for the hour.
You reported [fieldname] in the [type] record for [param] that is not rounded to the
appropriate precision for that parameter.
Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 262 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAD-36
Check Name:
Check Extraneous Fc Factor Record Fields
Related Former Checks:
Applicability:
Description:
Specifications:
Hourly Extraneous Fields = null
If (Current Fc Factor Record is not null)
If {Current Fc Factor Record. Fo rmu 1 a Idcnt i ficr is not null)
append "Formulaldentifier" to Hourly Extraneous Fields
If (Current Fc Factor Record Momio ri ngSy stc m ID is not null)
append "MonitoringSystemID" to Hourly Extraneous Fields
If (Current Fc Factor Record. Segllient Nullibe r is not null)
append "SegmentNumber" to Hourly Extraneous Fields
If (Current Fc Factor /?ec«/Y/.OpcratingConditionCodc is not null)
append "OperatingConditionCode" to Hourly Extraneous Fields
If {Current Fc Factor Record. SampleTypeCode is not null)
append "SampleTypeCode" to Hourly Extraneous Fields
If {Hourly Extraneous Fields is not null)
return result A
Results:
Result
A
You reported [fieldnames] in the HPFF record for FC for FuelCode [fueled]. This data Non-Critical Error
should be blank.
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Environmental Protection Agency
Page 263 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAD-37
Check Name:
Validate C02 Record
Related Former Checks:
Applicability:
Description:
Specifications:
Current C02 HPFFRecord = null
Count the HourlyParamFuelFlow record where
HourlyParamFuelFlow.HourlyFuelFlowID = Current Fuel Flow Hourly FuclFlow ID AND
HourlyParamFuelFlow.ParameterCode = "C02"
If (Count >1)
CO2 App D Accumulator = -1
return result A
Else If (Count == 0)
If (CO 2 App D Method Active For Hour == true)
CO2 App D Accumulator = -1
If (Legacy Data Evaluation == false)
return result H
Else if (CO 2 App D Method Active For Hour == true)
Current C02 HPFF Record = matching record
if (Current CO2 HPFF M o n i to ri ng Fo rm u 1 a I d is null
return result C
else
Cur C02 Mon Formula Record = Lookup active formula in MonitoringFormula Table where
MonitoringFormulalD = Current CO2 HPFF Mo ni to ri ng Fo rmu 1 a ID
if (Cur C02 Mon Formula Record is null)
return result D
else if (Cur C02 Mon Formula i?ecor "C02")
return result E
else if (Cur C02 Mon Formula Record.EquationCode <> "G-4")
return result F
return result B
else
else
return result G
Environmental Protection Agency
Page 264 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
A
B
C
D
E
F
G
H
Usage:
1
Response
You reported more than one HPFF record for [parameter] for FuelCode [fueled] for the
hour.
Your monitoring plan indicates the use of the Appendix D C02 method, but you did not
report an HPFF record for C02 for FuelCode [fueled] for the hour.
You did not report a FormulalD in the HPFF record for C02 for FuelCode [fueled].
You reported FormulalD [ID] in the HPFF record for C02 for FuelCode [fueled], but
there is no active Formula record for this formula in your monitoring plan.
You reported FormulalD [ID] in the HPFF record for C02 for FuelCode [fueled], but
this is not a C02 formula.
The FormulaCode of FormulalD [ID] reported in the HPFF record for C02 for
FuelCode [fueled] is invalid. The FormulaCode should be "G-4".
You reported an HPFF record for C02 for FuelCode [fueled], but you do not have an
active Appendix D C02 method for the hour.
Your monitoring plan indicates the use of the Appendix D C02 method, but you did not
report an HPFF record for C02 for FuelCode [fueled] for the hour. Fuel-specific C02
emissions data was not required in the EDR data, but is required for all data submitted
through ECMPS. The software will not recalculate C02 emissions values.
Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Informational Message
Environmental Protection Agency
Page 265 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAD-38
Check Name:
Check Extraneous C02 Record Fields
Related Former Checks:
Applicability:
Description:
Specifications:
Hourly Extraneous Fields = null
If (Current C02 HPFFRecord is not null)
If (Current C02 HPFF Mo nito ri ngSy stc m ID is not null)
append "MonitoringSystemID" to Hourly Extraneous Fields
If (Current C02 HPFF Record. SegmentNumber is not null)
append "SegmentNumber" to Hourly Extraneous Fields
If (Current C02 HPFF Record. Opc rat i ngCo ndit io nCodc is not null)
append "OperatingConditionCode" to Hourly Extraneous Fields
If (Current C02 HPFF Record. Sample T\ pc C ode is not null)
append "SampleTypeCode" to Hourly Extraneous Fields
If (Hourly Extraneous Fields is not null)
return result A
Results:
Result
A
Response
You reported [fieldnames] in the HPFF record for C02 for FuelCode [fueled]. This
data should be blank.
Severity
Non-Critical Error
Usage:
1 Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Environmental Protection Agency
Page 266 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAD-39
Check Name:
Calculate C02 Mass Rate
Related Former Checks:
Applicability:
Description:
Validation Tables:
Hourly Emissions Tolerances (Cross Check Table)
Specifications:
HFF Calc C02 = mill
If (Current C02 HPFFRecord is not null)
if (HFF Calc HI Rate is not null AND HFF Fc Factor is not null)
C02 HPFF Tolerance = Lookup Tolerance from Cross-Check Table "Hourly Emissions Tolerances" where
Parameter = "C02" AND
UOM = "TNHR"
HFF Calc C02 = HFF Calc HI Rate * HFF Fc Factor * 44.0 / (385.0 * 2000.0), and round the result to one decimal
place.
If Current Fuel Flow Record.FuelUsageTime > 0 AND Current Fuel Flow Record.FuelUsageTime <= 1 AND C02 App
D Accumulator >= 0)
// Note - this accumulates totals for all Fuel flow records and does not work like a normal parameter
CO2 App D Accumulator = C02 App D Accumulator + HFF Calc C02 * Current Fuel Flow
Record .FuelU sageT ime
else
CO2 App D Accumulator = -1
If (Current C02 HPFF Record. Pa ram Va 1F lie 1 >= 0)
if (ABS (HFF Calc C02 - Current C02 HPFF Record. ParamValFuel) > C02 HPFF Tolerance)
return result A
else
CO2 App D Accumulator = -1
return result B
Results:
Result
A
Response
The ParameterValueForFuel reported for HPFF record for C02 for FuelCode [fueled] is
inconsistent with the recalculated value.
The ParameterValueForFuel in the HPFF record for [parameter] for FuelCode [fueled]
could not be recalculated due to errors listed above.
Severity
Critical Error Level 1
B
Informational Message
Usage:
1 Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Environmental Protection Agency
Page 267 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAD-40
Check Name:
Check Reported C02 Mass Rate
Related Former Checks:
Applicability:
Description:
Specifications:
If (Current C02 HPFFRecord is not null)
If (Current C02 HPFF Record. Pa rain Va 1Fuc 1 is null or is less than 0
return result A
else if (Current C02 HPFF Record. Pa ram Va 1F uc 1 is not rounded to one decimal place)
return result B
Results:
Result
A
Response
The ParameterValueForFuel reported in the HPFF record for C02 for FuelCode
[fueled] is invalid. The value should be greater than or equal to 0.
You reported [fieldname] in the [type] record for [param] that is not rounded to the
appropriate precision for that parameter.
Severity
Critical Error Level 1
B
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Environmental Protection Agency
Page 268 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAD-44
Check Name:
Check C02 Units Of Measure
Related Former Checks:
Applicability:
Description:
Specifications:
If (Current C02 HPFFRecord is not null)
If (Current C02 HPFF Record. Pa ra mc tc rU OIVI Code <> "TNHR")
return result A
Results:
Result
A
Response
The ParameterUOMCode reported in the HPFF record for C02 for FuelCode [fueled] is Critical Error Level 1
missing or invalid. The value should be "TNHR".
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Environmental Protection Agency
Page 269 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAD-45
Check Name: Determine Appendix D Measure Codes
Related Former Checks:
Applicability:
Description:
Specifications:
If (Current Fuel Flow Record. SowceOfDatsMassCode in set {4, 5, 6} OR Current Fuel Flow Record. SourceOfDataVolumetricCode in
set {4, 5, 6} OR Monitor Measure Code Array for "FF" =="OTHER")
set Monitor Measure Code Array for "FF" to "OTHER"
else if (Current Fuel Flow Record. SourceOfDataMassCode in set {1, 3} OR Current Fuel Flow Record. SowceOfDataVolumetricCode
in set {1, 3})
if (Monitor Measure Code Array for "FF" begins with "MEAS")
set Monitor Measure Code Array for "FF" to "MEASSUB"
else
set Monitor Measure Code Array for "FF" to "SUB"
else if (Current Fuel Flow Record. SourceOfDataMassCode in set {0, 9} OR Current Fuel Flow Record. SowceOfDataVolumetricCode
in set {0, 9}))
if (Monitor Measure Code Array for "FF" contains "SUB")
set Monitor Measure Code Array for "FF" to "MEASSUB"
else
set Monitor Measure Code Array for "FF" to "MEASURE"
if (Current Sulfur Record is not null)
if (Current Sulfur Record. SampleTypeCode == 8)
if (Monitor Measure Code Array for "SULFUR" begins with "MEAS")
set Monitor Measure Code Array for "SULFUR" to "MEASSUB"
else
set Monitor Measure Code Array for "SULFUR" to "SUB"
else if (Current Sulfur Record. SampleTypeCode in set {0, I, 2, 4, 5, 6, 7})
if (Monitor Measure Code Array for "SULFUR" contains "SUB")
set Monitor Measure Code Array for "SULFUR" to "MEASSUB"
else
set Monitor Measure Code Array for "SULFUR" to "MEASURE"
if (Current GC VRecord is not null)
if (Current GC V Record .SampleTypeCode == 8)
if (Monitor Measure Code Array for "GCV" begins with "MEAS")
set Monitor Measure Code Array for "GCV" to "MEASSUB"
else
set Monitor Measure Code Array for "GCV" to "SUB"
else if (Current GCV Record. SampleTypeCode in set {0, 1, 2, 3, 4, 5, 6, 7})
if (Monitor Measure Code Array for "GCV" contains "SUB")
set Monitor Measure Code Array for "GCV" to "MEASSUB"
else
set Monitor Measure Code Array for "GCV" to "MEASURE"
if (Current Density Record is not null)
if (Current Density Record. SampleTypeCode == 8)
if (Monitor Measure Code Array for "DENSITY" begins with "MEAS")
set Monitor Measure Code Array for "DENSITY" to "MEASSUB"
else
set Monitor Measure Code Array for "DENSITY" to "SUB"
else if (Current Density Record. SampleTypeCode in set {1, 2, 5, 6, 7})
if (Monitor Measure Code Array for "DENSITY" contains "SUB")
set Monitor Measure Code Array for "DENSITY" to "MEASSUB"
Environmental Protection Agency
Page 270 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
else
set Monitor Measure Code Array for "DENSITY" to "MEASURE"
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Environmental Protection Agency
Page 271 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Category:
Hourly Appendix E
Environmental Protection Agency
Page 272 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAE-1
Check Name: Initialize AE Reporting Method
Related Former Checks:
Applicability:
Description:
Specifications:
App E Reporting Method = null
App E Op Code = null
App E Segment Number = null
App E Reported Value = null
App E Fuel Code = null
App E Calc HI = null
if {Current NOx Rate Method Code == "AE")
Total Fuel Sources = Hourly Fuel Flow Count for Gas + Hourly Fuel Flow Count for Oil
II App E Constant Fuel Mix detected when processing DHV records
if (Total Fuel Sources > 1)
App E Reporting Method = "MULTIPLE"
else if {Total Fuel Sources == 1)
App E Reporting Method = "SINGLE"
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Environmental Protection Agency
Page 273 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAE-2
Check Name:
Validate NOXR Record
Related Former Checks:
Applicability:
Description:
Specifications:
Current App E NOXR Record = null
App E NOXR HPFF Count for Gas = find matching HourlyParamFuelFlow records where
HourlyParamFuelFlow.HourlyFuelFlowID = Current Fuel Flow Hourly FuclFlow ID AND
HourlyParamFuelFlow.ParameterCode = "NOXR"
If (App E NOXR HPFF Count for Gas == 0)
if (App E Reporting Method in set {MULTIPLE, SINGLE})
NOXR App E Accumulator = -1
return result A
else if (If App E NOXR HPFF Count for Gas >1)
if (App E Reporting Method in set {MULTIPLE, SINGLE})
NOXR App E Accumulator = -1
return result B
else
return result D
Else if (App E Reporting Method in set {MULTIPLE, SINGLE})
Current App E NOXR Record = matching record
App E Segment Number = Current App E NOXR Record. SegmentNumber
App E Reported Value = Current App E NOXR Record. Pa ra m Va 1F lie 1
App E Calc HI = HFF Calc HI Rate
App E Fuel Code = Current Fuel Flow Record,¥uc\Co
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
A
B
C
D
Usage:
1
Response
You did not report an HPFF record for NOXR to report the NOx emission rate for
individual fuels.
You reported more than one HPFF record for NOXR for FuelCode [fueled] for the
hour.
The OperatingConditionCode reported in the HPFF record for NOXR for FuelCode
[FUELCD] is missing or invalid.
You reported an HPFF record for NOXR, but, according to your monitoring plan, you
use an Appendix E mixed fuel curve to determine the NOx emission rate. If this is the
case, you should report the NOx emission rate in a NOXR DHV record. The HPFF
record will not be evaluated and the NOx emissions rate will not be recalculated.
You reported an HPFF record for NOXR, but you have not defined a NOXR AE
method in your monitoring plan that is active during the current hour. The HPFF
record will not be evaluated and the NOx emissions rate will not be recalculated.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Process/Category: Emissions Data Evaluation Report ¦
¦ Hourly Fuel Flow
Environmental Protection Agency
Page 275 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAE-4
Check Name:
Check for Extraneous Fields in NOXR Record
Related Former Checks:
Applicability:
Description:
Specifications:
Hourly Extraneous Fields = null
if (Current App E NOXR Record is not null)
if (Current App E NOXR Record. SampleT\ pcCode is not NULL)
append "SampleTypeCode" to Hourly Extraneous Fields
if (Current App E NOXR wy/. Mo ni to ri ngFo rmu 1 a Id is not NULL)
append "MonitoringFormulalD" to Hourly Extraneous Fields
If (Hourly Extraneous Fields is not null)
return result A
Results:
Result
A
You reported [fieldnames] in the HPFF record for NOXR for FuelCode [fueled]. This Non-Critical Error
data should be blank.
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Environmental Protection Agency
Page 276 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAE-5
Check Name: Check Monitoring System Data for Appendix E NOXR
Related Former Checks:
Applicability:
Description:
Specifications:
if {Current App E NOXR Record is not null)
App E NOXE System ID = null
App E NOXE System Identifier = null
if {Current App E NOXR Record. Mo ni to ri ngSy stc m Id is null)
if {CurrentApp ENOXR Record.OperatingConditionCode== "E")
if {HFF Fuel Indicator Code <> "E")
return result A
else
return result B
// report Monitoring System in all other cases
else
Current App E NOXR Mon Sys Record = find MonitoringSystem record where
MonitoringSystem.MonitoringSystemld = Current App E NOXR Record .MonitoringSystemld
if {Current App E NOXR Mon Sys Record is null)
return result C
else if {Current App E NOXR Mon Sys Record. SystemTypeCode <> "NOXE"
return result D
else if {Current App E NOXR Mon Sys RecordFvlqXCo&q <> Current Fuel Flow Record. FuclCodc
return result E
else
App E NOXE System ID = Current App E NOXR Record .MonitoringSystemld
App E NOXE System Identifier = Current App E NOXR Mon Sys Record. Systemldentifier
Results:
Result
B
C
D
E
Usage:
1
Response
The OperatingConditionCode of E reported in the HPFF record for NOXR for
FuelCode [fueled] indicates that the fuel is an emergency fuel, but this is inconsistent
with the IndicatorCode in the UnitFuel record for the fuel.
You did not report a MonitoringSystemID in the HPFF record for NOXR for FuelCode
[fueled], but you did not report an OperatingConditionCode of E. You must report a
NOXE MonitoringSystemID for non-emergency fuels.
You reported MonitoringSystemID [ID] in the HPFF record for NOXR for FuelCode
[fueled], but there is no MonitorSystem record for this system in your monitoring plan
that was active during the hour.
You reported MonitoringSystemID [ID] in the HPFF record for NOXR for FuelCode
[fueled], but this system is not a NOXE monitoring system.
You reported NOXE MonitoringSystemID [ID] in the HPFF record for NOXR, but the
FuelCode of this system is not equal to FuelCode [fueled] in the associated HFF record.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Process/Category: Emissions Data Evaluation Report ¦
¦ Hourly Fuel Flow
Environmental Protection Agency
Page 277 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAE-7
Check Name:
Retrieve Appendix E Correlation Test Results or Default Value
Related Former Checks:
Applicability:
Description:
Specifications:
Maximum App E Curve NOx Emission Rate = null
App E NOx MER = null
App E Segment Total = null
If {App E Op Code in set {N, W, X, Y, Z} )
if {Current Appendix E Status begins with "IC" or "Undetermined")
QA Supp Attribute Count Record = matching record in QASuppAttribute where
QASuppAttribute.QASuppDatald = Prior Appendix E Record.QASwppDatald
QASuppAttribute. AttributeName = "SEGMENTCOUNT"
if {QA Supp Attribute Count Record is not null)
App E Segment Total = QA Supp AttributeCount Record. Attribute Value
Dimension App E Correlation NOx Rate Array with App E Segment Total elements
Dimension App E Correlation Heat Input Array with App E Segment Total elements
for (X = 1 to App E Segment Total)
QA Supp Attribute Segment NOx Record = matching record in QASuppAttribute where
QASuppAttribute.QASuppDatald = Prior Appendix E Record.QASwppDatald
QASuppAttribute.AttributeName = "NOX RATE X" (where X matches the loop variable)
if (QA Supp Attribute Segment NOx Record is not null)
if (QA Supp Attribute Segment NOx Record .Attribute Value > Maximum App E Curve NOx
Emission Rate
Maximum App E Curve NOx Emission Rate = QA Supp Attribute Segment NOx
Record. AttributeValue
App E Correlation NOx Rate Array\X\ = QA Supp Attribute Segment NOx
Record. Attribute V alue
QA Supp Attribute Segment HI Record = matching record in QASuppAttribute where
QASuppAttribute.QASuppDatald = Prior Appendix ERecord.QASwppDatald
QASuppAttribute. AttributeName = "HI RATE X" (where X matches the loop variable)
if (QA Supp Attribute Segment HI Record is not null)
App E Correlation Heat Input Array[X\ = QA Supp Attribute Segment HI Record .AttributeValue
else if (App E Op Code in set {E, M, U} )
Count active MonitoringDefault record for location where
ParameterCode = "NORX" AND
DefaultPurpose = "MD" AND
FuelCode = App E Fuel Code
if (Count <> 1)
return result A
else
Environmental Protection Agency Page 278 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
App E NOxMER Default Record = matching record
If (App E NOxMER Default Record. DefaultValue > 0
App E NOx MER = App E NOxMER Default Record. Default Value
else
return result B
Results:
Result Response Severity
A The NOx emission rate could not be determined, because you did not report one and Critical Error Level 1
only one missing data default record for NORX for FuelCode [fueled] in your
monitoring plan that was active during current hour.
B The NOx emission rate could not be determined, because the DefaultValue in the Critical Error Level 1
NORX default record for FuelCode [fueled] is invalid.
Usage:
1
Process/Category:
Emissions Data Evaluation Report — Hourly Configuration Evaluation
Conditions:
App E Checks Needed Equals true
2
Process/Category:
Emissions Data Evaluation Report NOx Emissions Rate Calculation Verification
Conditions:
App E Constant Fuel Mix Equals true
3
Process/Category:
Emissions Data Evaluation Report Hourly Fuel Flow
Conditions:
App E Constant Fuel Mix Equals false
Environmental Protection Agency
Page 279 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAE-8
Check Name: Determine Appendix E Curve Segment
Related Former Checks:
Applicability:
Description:
Specifications:
App E Calc Segment Num = null
if (App E Op Code is not null)
switch (App E Op Code)
case "E" or "U" or "M" or "W":
if App E Segment Number is not null
return result A
case "N" or "X":
If (App E Segment Total is not null)
if App E Segment Number is not null
if [App E Segment Number > number of elements in the App E Correlation NOx Rate Array)
return result B
else if (App E Correlation NOx Rate Array [App E Segment Number] <> Maximum App E
Curve NOx Emission Rate)
return result B
else
if (Legacy Data Evaluation == false)
return result G
case "Y" OR "Z":
If (App E Calc HI is not null) and (App E Segment Total is not null)
/= 1
while (i <= App E Segment Total AND App E C ale HI > App E Correlation Heat Input Rate Array[i\)
i = i + 1
if (i <= App E Segment Total AND App E Calc HI <= App E Correlation Heat Input Array\i\)
App E Calc Segment Num = i
if (App E Op Code == "Z")
if (App E Calc Segment Num <> 1)
return result C
else if App E Segment Number is null
if (Legacy Data Evaluation == false)
return result G
else if (App E Segment Number <> 1)
return result D
else if App E Segment Number is null
if (Legacy Data Evaluation == false)
return result G
Environmental Protection Agency
Page 280 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
else if {App E Calc HI == App E Correlation Heat Input Array\i\)
if (App E Segment Number <> App E Calc Segment Num AND App E Segment
Number <> App E Calc Segment Num +1)
return result E
else
if (App E Segment Number <> App E Calc Segment Num)
return result E
return result F
Results:
Result
A
B
C
D
E
F
Response
You reported a SegmentNumber in the HPFF or DHV record for NOXR for FuelCode
[fueled]. This field should be blank when OperatingConditionCode is [OpCode].
You reported an OperatingConditionCode of [OpCode] in the DHV or HPFF record for
NOXR for FuelCode [fueled], but the reported SegmentNumber does not represent the
segment on the Appendix E curve with the maximum NOx emission rate.
You reported an OperatingConditionCode of Z in the DHV or HPFF record for NOXR
for FuelCode [fueled], but the calculated heat input rate is not below the lowest point on
the Appendix E curve.
You reported an OperatingConditionCode of Z in the DHV or HPFF record for NOXR
for FuelCode [fueled], but you did not report a SegmentNumber of 1.
The SegmentNumber reported in the HPFF or DHV record for NOXR for FuelCode
[fueled] is inconsistent with the calculated heat input.
You reported an OperatingConditionCode of [OpCode] in the DHV or HPFF record for
NOXR for FuelCode [fueled], but the calculated heat input rate is higher than the
maximum heat input rate on the Appendix E curve. You should report an
OperatingConditionCode of W, and use the appropriate substitute data algorithm to
calculate the NOx emission rate.
You did not report a SegmentNumber in the HPFF or DHV record for NOXR for
FuelCode [fueled].
Severity
Critical Error Level 1
Non-Critical Error
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1
2
3
Process/Category:
Conditions:
Process/Category:
Conditions:
Process/Category:
Conditions:
Emissions Data Evaluation Report — Hourly Configuration Evaluation
App E Checks Needed Equals true
Emissions Data Evaluation Report NOx Emissions Rate Calculation Verification
App E Constant Fuel Mix Equals true
Emissions Data Evaluation Report Hourly Fuel Flow
App E Constant Fuel Mix Equals false
Environmental Protection Agency
Page 281 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAE-9
Check Name: Calculate Appendix E NOx Rate
Related Former Checks:
Applicability:
Description:
Validation Tables:
Hourly Emissions Tolerances (Cross Check Table)
Specifications:
App E Calculated NOx Rate for Source = null
if (App E Op Code in set {Y, Z})
If (App E Calc Segment Num is not null)
if (App E Calc Segment Num == 1)
App E Calculated NOx Rate for Source = App E Correlation NOx Rate Array[\\
else
y2 = App E Correlation NOx Rate Array[App E Calc Segment Num\
x2 = App E Correlation Heat Input Array[App E Calc Segment Num\
y 1 = App E Correlation NOx Rate Array[App E Calc Segment Num - 1 ]
xl = App E Correlation Heat Input Array[App E Calc Segment Num - 1]
slope = (y2 - y 1) / (x2 - xl)
App E Calculated NOx Rate for Source= slope * (AppE CalcHI - xl) +yl, and round the result to 3 decimal
places.
else if (App E Op Code in set {N, X})
App E Calculated NOx Rate for Source = Maximum App E Curve NOx Emission Rate
else if (App E Op Code in set {E, M, U})
App E Calculated NOx Rate for Source = App E NOx MER
else if (App E Op Code == "W" AND Maximum App E Curve NOx Emission Rate is not null AND App E Reported Value >= 0 AND
App E Reported Value is rounded to three decimal places)
If (App E Reported Value >= Maximum App E Curve NOx Emission Rate * 1.25 (rounded to 3 decimal places))
App E Calculated NOx Rate for Source = App E Reported Value
Count active MonitoringDefault record for location where
ParameterCode = "NORX" AND
DefaultPurpose = "MD" AND
FuelCode = App E Fuel Code
if (Count <> 1)
return result A
else
NOx MER Default Record = matching record
If (NOxMER DefaultRecord.DefaultValxie > 0)
If (App E Reported Value >= NOx MER Default Record. DefaultValue)
App E Calculated NOx Rate for Source = App E Reported Value
Environmental Protection Agency
Page 282 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
else
if (AppE Reporting Method == "CONSTANT" or "APPORTIONED")
return result B
else
NOXR App E Accumulator = -1
return result C
else
if {AppE Reporting Method == "CONSTANT" or "APPORTIONED")
return result D
else
NOXR App E Accumulator = -1
return result D
if (App E Calculated NOx Rate for Source is not null)
NOXR HPFF Tolerance = Lookup Tolerance from Cross-Check Table "Hourly Emissions Tolerances" where
Parameter = "NOXR" AND
UOM = "LBMMBTU"
if (App E Reporting Method == "CONSTANT")
if (App E Reported Value >= 0 AND A BS(/!/>/> E Calculated NOx Rate for Source - App E Reported Value) > NOXR
HPFF Tolerance)
return result E
if (AppE Reporting Method == "APPORTIONED")
Apportionment Calc NOXR Array at this Location = App E Calculated NOx Rate for Source
if (Rpt Period NOx Rate Calculated Accumulator Array for this location is not null)
if (Rpt Period NOx Rate Calculated Accumulator Array for this location >= 0)
Rpt Period NOx Rate Calculated Accumulator Array for this location = Rpt Period NOx Rate
Calculated Accumulator Array for this location + App E Calculated NOx Rate for Source
else
Rpt Period NOx Rate Calculated Accumulator Array for this location = App E Calculated NOx Rate for Source
Rpt Period NOx Rate Hours Accumulator Array for this location = Rpt Period NOx Rate Hours Accumulator Array for
this location + 1
Set Current Measure Code to the Monitor Measure Code Array for "NOXR".
if (App E Reported Value >= 0 AND A BS(/!/>/> E Calculated NOx Rate for Source - App E Reported Value) > NOXR
HPFF Tolerance)
return result E
else
If Current Fuel Flow Record.FuelUsageTims >0 AND Current Fuel Flow Record.FuelUsageTims <= 1 AND NOXR
App E Accumulator >= 0 AND App E Calc HI is not null)
NOXR App E Accumulator = NOXR App E Accumulator + (App E Calculated NOx Rate for Source * Current
Fuel Flow /?6'ewY/.FuclUsagcTimc * AppE Calc HI)
else
NOXR App E Accumulator = -1
if (App E Reported Value >= 0 AND A BS(/!/>/> E Calculated NOx Rate for Source - App E Reported Value) > NOXR
HPFF Tolerance)
return result F
else
if (App E Reporting Method == "CONSTANT")
Environmental Protection Agency
Page 283 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
return result G
else if (App E Reporting Method == "APPORTIONED")
Apportionment Calc NOXR Array at this Location = -1
Rpt Period NOX Rate Calculated Accumulator Array for this location = -1
return result G
else if (App E Op Code is not null)
NOXR App E Accumulator = -1
return result H
Results:
Result
A
B
C
D
E
F
G
H
Response
The NOx emission rate could not be determined, because you did not report one and
only one missing data default record for NORX for FuelCode [fueled] in your
monitoring plan that was active during current hour.
You reported an OperatingConditionCode of W in the DHV record for NOXR for
FuelCode [fueled], but the AdjustedHourly Value is less than the minimum allowable
substitute data value according to Appendix E sec. 2.5.2.1.
You reported an OperatingConditionCode of W in the HPFF record for NOXR for
FuelCode [fueled], but the ParameterValueForFuel is less than the minimum allowable
substitute data value according to Appendix E sec. 2.5.2.1.
The NOx emission rate could not be determined, because the DefaultValue in the
NORX default record for FuelCode [fueled] is invalid.
The AdjustedHourly Value reported in the DHV record for [param] is inconsistent with
the recalculated value.
The ParameterValueForFuel reported in the HPFF record for NOXR for FuelCode
[fueled] is inconsistent with the value recalculated from the Appendix E curve.
The AdjustedHourly Value in the DHV record for [param] could not be recalculated due
to errors listed above.
The ParameterValueForFuel in the HPFF record for [parameter] for FuelCode [fueled]
could not be recalculated due to errors listed above.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Informational Message
Informational Message
Usage:
1
2
3
Process/Category:
Conditions:
Process/Category:
Conditions:
Process/Category:
Conditions:
Emissions Data Evaluation Report — Hourly Configuration Evaluation
App E Checks Needed Equals true
Emissions Data Evaluation Report NOx Emissions Rate Calculation Verification
App E Constant Fuel Mix Equals true
Emissions Data Evaluation Report Hourly Fuel Flow
App E Constant Fuel Mix Equals false
Environmental Protection Agency
Page 284 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAE-13
Check Name:
Check Reported NOx Emission Rate
Related Former Checks:
Applicability:
Description:
Specifications:
If {Current Appe E NOXR Record is not null)
If (Current App E NOXR Record. Para m Va 1Fuc 1 is null or is less than 0
return result A
else if (Current App E NOXR Record. P a ra m Va 1F uc 1 is not rounded to three decimal places)
return result B
Results:
Result
A
Response
The ParameterValueforFuel reported in the HPFF record for NOXR for FuelCode
[fueled] is invalid. The value must be greater than or equal to 0.
You reported [fieldname] in the [type] record for [param] that is not rounded to the
appropriate precision for that parameter.
Severity
Critical Error Level 1
B
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Environmental Protection Agency
Page 285 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAE-14
Check Name:
Check NOXR Units Of Measure
Related Former Checks:
Applicability:
Description:
Specifications:
If {Current App E NOXR Record is not null)
If (Current App E NOXR Record.ParameterUOMCode <> "LBMMBTU")
return result A
Results:
Result
A
Response
The ParameterUOMCode reported in the HPFF record for NOXR for FuelCode [fueled] Critical Error Level 1
is missing or invalid. The value should be "LBMMBTU".
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Hourly Fuel Flow
Environmental Protection Agency
Page 286 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAE-15
Check Name:
Determine Appendix E Measure Code
Related Former Checks:
Applicability:
Description:
Specifications:
if (App E Op Code is not null)
If (App E Op Code = "E" or Monitor Measure Code Array for "NOXR" =="OTHER")
set Monitor Measure Code Array for "NOXR" to "OTHER"
else if (App E Op Code in set {M, U, N})
if (Monitor Measure Code Array for "NOXR" begins with "MEAS")
set Monitor Measure Code Array for "NOXR" to "MEAS SUB"
else
set Monitor Measure Code Array for "NOXR" to "SUB"
else if (App E Op Code in set {W, X, Y, Z})})
if (Monitor Measure Code Array for "NOXR" contains "SUB")
set Monitor Measure Code Array for "NOXR" to "MEASSUB"
else
set Monitor Measure Code Array for "NOXR" to "MEASURE"
Results:
Result
Response
Severity
Usage:
2
3
Process/Category:
Conditions:
Process/Category:
Conditions:
Process/Category:
Conditions:
Emissions Data Evaluation Report — Hourly Configuration Evaluation
App E Checks Needed Equals true
Emissions Data Evaluation Report NOx Emissions Rate Calculation Verification
App E Constant Fuel Mix Equals true
Emissions Data Evaluation Report Hourly Fuel Flow
App E Constant Fuel Mix Equals false
Environmental Protection Agency
Page 287 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Category:
Hourly Apportionment
Environmental Protection Agency
Page 288 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAPP-1
Check Name:
Determine Monitoring Plan Configuration
Related Former Checks:
Applicability:
Description:
Specifications:
MP Stack Config for Hourly Checks = null
MP Pipe Config for Hourly Checks = null
MP Load UOM = null
MP Unit Load = null
Stack OpTime Accumulator = 0
Stack LoadTimesOpTime Accumulator = 0
Pipe LoadTimesOpTime Accumulator = 0
Config HeatlnputTimesOpTime Accumulator = 0
Config NOxRateTimesHeatlnput Accumulator = 0
Config NOxRateTimesOpTime Accumulator = 0
Config OpTime Accumulator = 0
Config Heatlnput Accumulator = 0
Max Stack OpTime = 0
Unit OpTime Accumulator = 0
Unit LoadTimesOpTime Accumulator = 0
Unit HeatlnputTimesOpTime Accumulator = 0
Max Unit OpTime = 0
CP Fuel Count = 0
Current Month = month from Current Date
App E Reporting Method = null
App E Op Code = null
App E Segment Number = null
App E Reported Value = null
App E Fuel Code = null
App E Calc HI = null
App E NOXE System ID = null
App E NOXE System Identifier = null
CurrentAppendixEStatus = null
EarliestLocationReportDate = null
Current Measure Code = null
Set Monitor Measure Code Array to null for each parameter.
For each array below, initialize each array with Current Location Count entries and the values as described
Apportionment OpTime Array - set each element in array to 0.0
Apportionment Load Array - set each element in array to 0
Apportionment Calc HI Array - set each element in array to 0.0
Apportionment CalcNOXR Array - set each element in array to 0.0
Apportionment HI Method Array - set each element in array to null
Apportionment NOX Method Array - set each element in array to null
Apportionment HI Measure Code Array - set each element in array to null
Apportionment NOXR Measure Code Array - set each element in array to null
Apportionment Stack Unit List - set each element in array to null
Apportionment NOXR Method Array - set each element in array to null
If Current Location Count > 1
Find List of MonitorLocationlds in MonitorPlanLocation Table that match Current Monitoring Plan Id
Environmental Protection Agency
Page 289 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
For each MonitorLocationld in list, lookup record in MonitorLocation table
if StackPipeld is not null, add StackPipeld to StackPipe list
if Unitld is not null, add Unitld to Unit list
MS Count = 0
MP Count = 0
CS Count = 0
CP Count = 0
Unit Count = 0
CS Unit Count = 0
CP Unit Count = 0
Unit MS Count = 0
For each MonitorLocationld in list, lookup record in MonitorLocation table
if MonitorLocation.StackPipelD is not null,
set Stack Unit Count to 0
for each UnitStackConfiguration record where
BeginDate <= Current Date AND EndDate >= Current Date AND
StackPipeld = MonitorLocation. StackPipeld
add 1 to Stack Unit Count
append MonitorLocationID of the unit to Apportionment Stack Unit List for the stack location
if (StackPipe Unit Count > 0)
if {MonitorLocation. StackPipeName begins with "MS")
add 1 to MS Count
else if {MonitorLocation. StackPipeName begins with "MP")
add 1 to MP Count
else if {MonitorLocation. StackPipeName begins with "CS")
add 1 to CS Count
f (CS Count == 1)
CS Unit Count = Stack Unit Count
else if {MonitorLocation. StackPipeName begins with "CP")
add 1 to CP Count
if {CP Count ==1)
CP Unit Count = Stack Unit Count
else if Unitld is not null
add 1 to Unit Count
if {Unit Count == 1)
Unit MS Count = number of UnitStackConfiguration records where
UnitStackConfiguration .BeginDate <= Current Date AND
UnitStackConfiguration.EndDate >= Current Date AND
UnitStackConfiguration.UnitID = MonitorLocation. UnitLd
UnitStackConfiguration. StackPipeName begins with "MS"
if (MS Count > 1 AND CS Count == 0 AND Unit Count == 1 AND MS Count == Unit MS Count)
MP Stack Config for Hourly Checks = 'MS"
Environmental Protection Agency
Page 290 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Multiple Stack Configuration = true
else if (CS Count == 1 AND MS Count == 0 AND Unit Count > 1 AND Unit Count = = CS Unit Count)
MP Stack Configfor Hourly Checks = "CS"
else if (CS Count == 1 AND MS Count > 0)
MP Stack Config for Hourly Checks = "CSMS"
else if (CS Count + MS Count > 0)
MP Stack Config for Hourly Checks = "COMPLEX"
If (CP Count == 1 AND MP Count == 0 AND Unit Count > 1 AND Unit Count == CP Unit Count)
MP Pipe Config for Hourly Checks = "CP"
else if (CP Count + MP Count > 0)
MP Pipe Configfor Hourly Checks = 'MULTIPLE"
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report — Hourly Configuration Initialization
Environmental Protection Agency
Page 291 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAPP-2
Check Name: Pre-Validate Heat Input Calculation
Related Former Checks:
Applicability:
Description:
Specifications:
Calculate Apportioned HI = false
Calculate NOXM From Apportioned HI = false
if Current Monitor Plan Location Record. StackPipc ID is not null
If the StackPipelD of the monitoring location begins with "CS",
set Current HI Entity Type = "CS"
If the StackPipelD of the monitoring location begins with "CP",
set Current HI Entity Type = "CP"
If the StackPipelD of the monitoring location begins with "MS",
set Current HI Entity Type = 'MS"
If the StackPipelD of the monitoring location begins with "MP",
set Current HI Entity Type = 'MP"
else if the UnitID of the monitoring location is not null
set Current HI Entity Type = "Unit"
If (Apportionment HI Method Array for the location contains "CALC") OR {Apportionment HI Method Array for the location ==
"COMPLEX")
If {MP Pipe Config for Hourly Checks == "CP" AND CP Fuel Count > 1)
Apportionment HI Method Array for the location == "NOCALC"
If {Apportionment Op Time Array for the location > 0 AND Apportionment Op Time Array for the location <= 1)
// F-25
If {MP Stack Config for Hourly Checks == "CS" AND Current HI Entity Type = "CS")
if {Apportionment NOX Method Array == "NOXR")
Calculate NOXM From Apportioned HI = true
If Apportionment OpTime Array for the location < Max Unit OpTime
return result A
else if Apportionment OpTime Array for the location > Unit OpTime Accumulator + (the number of units in the
monitoring plan * .005)
return result B
else
If {Config HeatlnputTimesOpTime Accumulator > 0)
Calculate Apportioned HI = true
if {MPLoad UOM <> "INVALID" AND StackLoadTimesOpTime Accumulator > 0 AND Unit
LoadTimesOpTime Accumulator > 0 AND abs{Stack LoadTimesOpTime Accumulator - Unit
LoadTimesOpTime Accumulator) >= number of items in the Apportionment OpTime Array)
return result C
// F-21A/B
else if {{MP Stack Config for Hourly Checks == "CS" OR MP Pipe Config for Hourly Checks == "CP") AND
Apportionment HI Method Array for the location not in set {NOCALC, COMPLEX})
Environmental Protection Agency
Page 292 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
if {Apportionment NOX Method Array == "NOXR")
Calculate NOXM From Apportioned HI = true
If Max Stack OpTime < Max Unit OpTime AND MP Pipe Config for Hourly Checks is null
return result A
else if Max Stack OpTime > Unit OpTime Accumulator + (the number of units in the monitoring plan * .005)
AND MP Pipe Config for Hourly Checks is null
return result B
else if MP Load UOM <> "INVALID"
if ((MP Pipe Config for Hourly Checks<> "CP" AND MP Stack Configfor Hourly Checks== "CS"
AND StackLoadTimesOpTime Accumulator > 0 AND Unit LoadTimesOpTime Accumulator > 0 AND
{Stack LoadTimesOpTime Accumulator - Unit LoadTimesOpTime Accumulator) > number of items in
the Apportionment OpTime Array)
return result C
else if (Config HeatlnputTimesOpTime Accumulator >= 0 AND Apportionment Load Array for this
Location >= 0 AND Unit LoadTimesOpTime Accumulator >= 0 AND Apportionment Calc HI Array for
this Location >= 0)
Calculate Apportioned HI = true
If (Unit LoadTimesOpTime Accumulator == 0)
Apportionment HI Method Array for the location == "NOCALC"
// Cannot apportionment but will validate total configuration
else if ((MP Stack Config for Hourly Checks begins with "CS" OR MP Pipe Config for Hourly Checks == "CP" OR MP
Pipe Config for Hourly Checks == 'MULTIPLE") AND Apportionment HI Method Array for the location <>
"COMPLEX")
if (Apportionment NOX Method Array == "NOXR")
Calculate NOXM From Apportioned HI = true
If Max Stack OpTime > Unit OpTime Accumulator + (the number of units in the monitoring plan * .005) AND
MP Pipe Config for Hourly Checks is null
return result B
else if (Config HeatlnputTimesOpTime Accumulator > 0 and Unit HeatlnputTimesOpTime Accumulator == 0)
OR (Config HeatlnputTimesOpTime Accumulator == 0 AND Unit HeatlnputTimesOpTime Accumulator > 0)
return result G
else if (Config HeatlnputTimesOpTime Accumulator >= 0 AND Unit HeatlnputTimesOpTime Accumulator >=
0)
Calculate Apportioned HI = true
// COMPLEX
else if (MP Stack Config for Hourly Checks == "COMPLEX" OR Apportionment HI Method Array for the location ==
"COMPLEX")
if (Apportionment NOX Method Array == "NOXR")
Calculate NOXM From Apportioned HI = true
if (Config HeatlnputTimesOpTime Accumulator > 0 and Unit HeatlnputTimesOpTime Accumulator == 0) OR
(Config HeatlnputTimesOpTime Accumulator == 0 AND Unit HeatlnputTimesOpTime Accumulator > 0)
return result G
else if (Config HeatlnputTimesOpTime Accumulator >= 0 AND Unit HeatlnputTimesOpTime Accumulator >=
0)
Calculate Apportioned HI = true
//F-21C
else if (MP Stack Config for Hourly Checks == 'MS")
Environmental Protection Agency
Page 293 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
if {Apportionment NOX Method Array == "NOXR")
Calculate NOXM From Apportioned HI = true
if (ConfigHeatlnputTimesOpTime Accumulator >= 0)
Calculate Apportioned HI = true
If Apportionment OpTime Array for the location < Max Stack OpTime
return result D
else if Apportionment OpTime Array for the location > Stack OpTime Accumulator
return result E
else if (Current Entity Type <>"Unit" AND Apportionment OpTime Array for the location > 0 AND the sum of Apportionment OpTime
Array for all units in the Apportionment Stack Unit List for the location == 0)
if (Current Entity Type starts with "C")
return result B
else
return result D
else if (Current Entity Type == 'MS" AND MP Load UOM <> "INVALID" and MP Unit Load > 0 AND Apportionment Load Array for
the location > 0)
if (MP Unit Load o Apportionment Load Array for the location)
return result F
Results:
Result
A
B
C
D
E
F
G
Usage:
1
Response
The OperatingTime reported at the common stack/pipe is less than the OperatingTime
reported for one or more units linked to the stack/pipe.
The OperatingTime reported for one (or more) stacks/pipes is greater than the sum of
the operating times reported for the units for the hour.
The HourLoad reported at the common stack/pipe is inconsistent with the load and
operating time values reported at the units linked to the stack/pipe.
The OperatingTime reported for the unit is less than the OperatingTime reported for
one or more multiple stacks linked to the unit.
The OperatingTime reported for the unit is greater than the sum of operating times at
the multiple stacks linked to the unit.
The HourLoad in the Hourly Operating record for all multiple stacks linked to this unit
are not equal.
The Heat Input Rate and Operating Time reported for the unit is inconsistent with the
Heat Input Rates and Operating Times for the configuration.
Process/Category: Emissions Data Evaluation Report — Hourly Configuration Evaluation
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 294 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAPP-3
Check Name:
Calculate Apportioned or Summed Heat Input Rate
Related Former Checks:
Applicability:
Description:
Validation Tables:
Hourly Emissions Tolerances (Cross Check Table)
Specifications:
Current HI Apportionment Record = null
HI Calculated Apportioned Value = null
App E Checks Needed = false
If (Apportionment HI Method Array for the location contains "CALC" OR Apportionment HI Method Array fox the location equals
"COMPLEX")
If {Calculate Apportioned HI = true)
Count active DerivedHourlyValueData records for location
WHERE ParameterCode = "HI"
If (Count ==1)
Current HI Apportionment Record = matching record
Heat Input Tolerance = Lookup Tolerance from Cross-Check Table "Hourly Emissions Tolerances" where
// F-25
If {MP Stack Config for Hourly Checks == "CS" AND Current HI Entity Type = "CS")
If {Calculate Apportioned HI == true)
HI Calculated Apportioned Value = Config HeatlnputTimesOpTime Accumulator / Apportionment OpTime
Array for this Location, rounded to one decimal place.
if {Current Month is not April OR Annual Reporting Requirement == true)
If {Rpt Period HI Calculated Accumulator for this location >= 0)
Rpt Period HI Calculated Accumulator for this location = Rpt Period HI Calculated
Accumulator for this location + {HI Calculated Apportioned Value * Apportionment OpTime
Array for this Location)
if {Current Month is April)
April HI Calculated Accumulator for this location = April HI Calculated Accumulator for this
location + {HI Calculated Apportioned Value * Apportionment OpTime Array for this Location)
if (Current HI Apportionment Record. Adj ustedHourly Value >= 0 AND ABS{Current HI Apportionment
Record. Adj ustedHourly Value - HI Calculated Apportioned Value) > Heat Input Tolerance)
return result A
else if {Apportionment OpTime Array for the location <> 0)
if {Current Month is not April OR Annual Reporting Requirement == true)
Rpt Period HI Calculated Accumulator for this location = -1
return result B
Parameter = "HI" AND
UOM = "MMBTUHR"
else
Calculate Apportioned HI = false
Environmental Protection Agency
Page 295 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
// other complex situations
else if {Current HI Entity Type<> "Unit")
If {Calculate Apportioned HI == true AND Current HI Apportionment Record. AdjustedHourlyVaiue >= 0)
HI Calculated Apportioned Value = Current Hf Apportionment Record. Ad) ustedHourlv Value
if {Current Month is not April OR Annual Reporting Requirement == true)
If (Rpt Period HI Calculated Accumulator for this location >= 0)
Rpt Period HI Calculated Accumulator for this location = Rpt Period HI Calculated
Accumulator for this location + {HI Calculated Apportioned Value * Apportionment OpTime
Array for this Location)
if {Current Month is April)
April HI Calculated Accumulator for this location = April HI Calculated Accumulator for this
location + {HI Calculated Apportioned Value * Apportionment OpTime Array for this Location)
else if {Apportionment OpTime Array for the location <> 0)
if {Current Month is not April OR Annual Reporting Requirement == true)
Rpt Period HI Calculated Accumulator for this location = -1
return result B
// F-21A/B
else if {{MP Stack Config for Hourly Checks == "CS" OR MP Pipe Config for Hourly Checks == "CP") AND
(Apportionment HI Method Array for the location not in set {NOCALC, COMPLEX})
If (Apportionment NOXR Method Array for the location = "AE")
App E Checks Needed = true
If {Calculate Apportioned HI == true)
if {Unit LoadTimesOpTime Accumulator > 0 OR Current HI Apportionment Record. Ad)ustedRourlyValue >=
0)
if {Unit LoadTimesOpTime Accumulator >0)
HI Calculated Apportioned Value = {Config HeatlnputTimesOpTime Accumulator*
Apportionment OpTime Array for this Location * Apportionment Load Array for this Location /
Unit LoadTimesOpTime Accumulator ) / Apportionment OpTime Array for this Location),
rounded to one decimal place.
else
HI Calculated Apportioned Value = Current HI Apportionment Record. AdjustedHourly Value
HI Calculated Apportioned Value = HI Calculated Apportioned Value + Apportionment Calc HI Array
for this Location
if {Current Month is not April OR Annual Reporting Requirement == true)
If {Rpt Period HI Calculated Accumulator for this location >= 0)
Rpt Period HI Calculated Accumulator for this location = Rpt Period HI Calculated
Accumulator for this location + {HI Calculated Apportioned Value * Apportionment
OpTime Array for this Location)
if {Current Month is April)
April HI Calculated Accumulator for this location = April HI Calculated Accumulator
for this location + {HI Calculated Apportioned Value * Apportionment OpTime Array
Environmental Protection Agency
Page 296 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
for this Location)
if (Current HI Apportionment Record. AdjustedHowlyVahie >= 0 AND ABS (Current HI
Apportionment Record. Ad) ustcdHourly Value - HI Calculated Apportioned Value) > Heat Input
Tolerance)
return result A
else if (Apportionment Op Time Array for the location <> 0)
if (Current Month is not April OR Annual Reporting Requirement == true)
Rpt Period HI Calculated Accumulator for this location = -1
return result B
else if (Apportionment OpTime Array for the location <> 0)
if (Current Month is not April OR Annual Reporting Requirement == true)
Rpt Period HI Calculated Accumulator for this location = -1
return result B
// Cannot apporition or Complex configuration
else if (MP Stack Config for Hourly CAecfcs begins with" CS" OR MP Stack Configfor Hourly Checks == "COMPLEX" OR
MP Pipe Configfor Hourly Checks in set {CP, MULTIPLE})
If (Apportionment NOXR Method Array for the location = "AE")
App E Checks Needed = true
If (Calculate Apportioned HI == true)
If (ABS(Config HeatlnputTimesOpTime Accumulator - UnitHeatlnputTimesOpTimeAccumulator) <= Heat
Input 'tolerance OR Apportionment HI Method Array for the location == "COMPLEX" OR (MP Stack Config
for Hourly Checks== "COMPLEX" and MP Pipe Config for Hourly Checks is null))
HI Calculated Apportioned Value = Current HI Apportionment Record .AdjustedHourlyValue
if (Current Month is not April OR Annual Reporting Requirement == true)
If (Rpt Period HI Calculated Accumulator for this location >= 0)
Rpt Period HI Calculated Accumulator for this location = Rpt Period HI Calculated
Accumulator for this location + (HI Calculated Apportioned Value * Apportionment
OpTime Array for this Location)
if (Current Month is April)
April HI Calculated Accumulator for this location = April HI Calculated Accumulator
for this location + (HI Calculated Apportioned Value * Apportionment OpTime Array
for this Location)
else
if (Current Month is not April OR Annual Reporting Requirement == true)
Rpt Period HI Calculated Accumulator for this location = -1
return result C
else if (Apportionment OpTime Array for the location <> 0)
if (Current Month is not April OR Annual Reporting Requirement == true)
Rpt Period HI Calculated Accumulator for this location = -1
Count active DerivedHourlyValueData records for location
WHERE ParameterCode = "HI"
If (Count ==1)
Current HI Apportionment Record = matching record
Environmental Protection Agency
Page 297 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
if (Current HI Apportionment Record. Ad) ustcdHourly Value > 0 AND Config HeatlnputTimesOpTime
Accumulator == 0)
return result D
else
return result B
else
return result B
// F-21C
else if {MP Stack Config for Hourly Checks == 'MS")
If {Calculate Apportioned HI == true)
HI Calculated Apportioned Value = Config HeatlnputTimesOpTime Accumulator / Unit OpTime Accumulator,
rounded to one decimal place.
if {Current Month is not April OR Annual Reporting Requirement == true)
If {Rpt Period HI Calculated Accumulator for this location >= 0)
Rpt Period HI Calculated Accumulator for this location = Rpt Period HI Calculated
Accumulator for this location + {HI Calculated Apportioned Value * Unit OpTime
Accumulator)
if {Current Month is April)
April HI Calculated Accumulator for this location = April HI Calculated Accumulator for this
location + {HI Calculated Apportioned Value * Apportionment OpTime Array for this Location)
if {Current HI Apportionment Record. Ad) ustcdHourly Value >= 0 AND ABS(Current HI Apportionment
Record. A dj ustcdHourly Value - HI Calculated Apportioned Value) > Heat Input Tolerance)
return result A
else if {Apportionment OpTime Array for the location <> 0)
if {Current Month is not April OR Annual Reporting Requirement == true)
Rpt Period HI Calculated Accumulator for this location = -1
return result B
Results:
Result
A
B
C
D
Usage:
1
Response Severity
The AdjustedHourly Value reported in the DHV record for HI is inconsistent with the Critical Error Level 1
recalculated apportioned or summed value.
The AdjustedHourly Value in the DHV record for [param] could not be recalculated due Informational Message
to other errors listed in this report.
The heat input calculated for the configuration is inconsistent with the sum of the
reported heat input at the units in this configuration.
You reported heat input at the unit, but there was no heat input at any of the locations
where heat input was measured.
Process/Category: Emissions Data Evaluation Report — Hourly Configuration Evaluation
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 298 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURAPP-4
Check Name: Calculate NOx Mass Rate from Apportioned or Summed Heat Input Rate
Related Former Checks:
Applicability:
Description:
Validation Tables:
Hourly Emissions Tolerances (Cross Check Table)
Specifications:
Current NOX Apportionment Based Record = null
NOX Calculated Apportionment Based Value = null
If (Calculate NOXM From Apportioned HI == true)
If (HI Calculated Apportioned Value is not null AND Apportionment Calc NOXR Array for this location >= 0)
Count active DerivedHourlyValueData records for location and hour
WHERE ParameterCode = "NOX"
If (Count ==1)
Current NOX Apportionment Based Record = matching record
NOX Tolerance = Lookup Tolerance from Cross-Check Table "Hourly Emissions Tolerances" where
Parameter = "NOX" AND
UOM = "LBHR"
NOX Calculated Apportionment Based Value = HI Calculated Apportioned Value * Apportionment Calc NOXR
Array, rounded to one decimal place.
if (Current Month is not April OR Annual Reporting Requirement == true
if (Apportionment OpTime Array for this location is between 0 and 1 (inclusive))
If (Rpt Period NOX Mass Calculated Accumulator for this location) >= 0)
Rpt Period NOX Mass Calculated Accumulator fox this location = Rpt Period NOX
Mass Calculated Accumulator for this location + (NOX Calculated Apportionment
Based Value * Apportionment OpTime Array for this location)
if (Current Month is April)
April NOX Mass Calculated Accumulator for this location = April NOX Mass
Calculated Accumulator for this location + (NOX Calculated Apportionment Based
Value * Apportionment OpTime Array for this location)
else
Rpt Period NOX Mass Calculated Accumulator for this location = -1
if (Current NOX Apportionment Record. AdjustedHourlyValue >= 0)
If (ABS(Current HI Apportionment /?6'«;/Y/.AdjustcdHourlv Value - NOX Calculated Apportionment
Based Value) > NOX Tolerance)
If (Legacy Data Evaluation == false)
return result A
else if (Apportionment OpTime Array for this Location is greater than 0 and less than or equal to
1)
If (A B S( Current HI Apportionment Record. Adj ustcdHourly V al lie - NOX Calculated
Environmental Protection Agency
Page 299 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Apportionment Based Value) > NOX Tolerance / Apportionment Op Time Array for this
Location)
return result A
else
if {Current Month is not April OR Annual Reporting Requirement == true)
Rpt Period NOX Mass Calculated Accumulator for this location = -1
return result B
if {Current Month is not April OR Annual Reporting Requirement == true)
Rpt Period NOX Mass Calculated Accumulator for this location = -1
return result B
Results:
Result Response Severity
A The AdjustedHourly Value reported in the DHV record for [param] is inconsistent with Critical Error Level 1
the recalculated value.
B The AdjustedHourly Value in the DHV record for [param] could not be recalculated due Informational Message
to other errors listed in this report.
Usage:
1 Process/Category: Emissions Data Evaluation Report — Hourly Configuration Evaluation
Environmental Protection Agency
Page 300 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAPP-5
Check Name:
Sum Weighted NOx Emission Rate from Multiple Stacks
Related Former Checks:
Applicability:
Description:
Specifications:
If {MP Stack Conjig for Hourly Checks == 'MS" AND Current HI Entity Type == "Unit")
If {Config NOxRateTimesHeatlnput Accumulator <> 0 OR Config NOxRateTimesOpTime Accumulator <> 0)
Expected Summary Value NOx Rate Array for this location = true
If {Config NOxRateTimesHeatlnput Accumulator > 0 AND Config Heatlnput Accumulator > 0 AND Rpt Period NOX
Rate Calculated Accumulator Array for this location >= 0)
Rpt Period NOX Rate Calculated Accumulator Array for this location = Rpt Period NOX Rate Calculated
Accumulator for this location + {Config NOxRateTimesHeatlnput Accumulator / Config Heatlnput
Accumulator, rounded to 3 decimal places.)
Rpt Period NOX Rate Hours Accumulator Array for this location = Rpt Period NOX Rate Hours Accumulator
for this location + 1
else if {Config NOxRateTimesOpTime Accumulator > 0 AND Config OpTime Accumulator > 0 AND Rpt Period NOX
Rate Calculated Accumulator Array for this location >= 0)
Rpt Period NOX Rate Calculated Accumulator Array for this location = Rpt Period NOX Rate Calculated
Accumulator for this location + {Config NOxRateTimesOpTime Accumulator / Config OpTime Accumulator,
rounded to 3 decimal places.)
Rpt Period NOX Rate Hours Accumulator Array for this location = Rpt Period NOX Rate Hours Accumulator
for this location + 1
else
Rpt Period NOX Rate Calculated Accumulator Array for this location = -1
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report — Hourly Configuration Evaluation
Environmental Protection Agency
Page 301 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAPP-6
Check Name:
Related Former Checks:
Initialize Variable for Calculating Appendix E NOx Rate via Apportionment
Applicability:
Description:
Specifications:
If (App E Checks Needed == true)
App E Op Code = null
App E Reporting Method = "APPORTIONED"
Count active DerivedHourly ValueData records for location and hour
WHERE ParameterCode = "NOX"
If (Count == 1)
Current NOXR Apportionment Based Record = matching record
if (Current NOXR Apportionment Based RecordMomtormgSystemlD is not null)
Mon Sys Record = find active MonitoringSystemData record for location where
MonitoringSy stemData.MonitoringSystemID = Current NOXR Apportionment Based
Record. Mo ni to ri ngSy stem ID
if (found AND Mon Sys Record. SystemTypeCode == "NOXE" AND Mon ,SV.v /tecwc/.FuclTvpcCodc is not null)
if (Current NOXR Apportionment Based Record.OpemtingConditionCode in set {X, Y, Z, U, W, N, M})
App E Op Code= Current NOXR Apportionment Based Record.OperatingConditionCode
App E CalcHI = HI Calculated Apportioned Value
App E Reported Value = Current NOXR Apportionment Based Record. k
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
B
C
Usage:
1
Response
You reported an OperatingConditionCode of E in the DHV record for NOXR. You
should report the NOx emission rate for emergency fuels in an HPFF record, not a
DHV record.
The OperatingConditionCode reported in the DHV record for NOXR is missing or
invalid.
According to your monitoring plan, your reported that you are determining NOx
emission rate using the Appendix E methodology, but you did not report a
MonitoringSystemID in this record. You should report the MonitoringSystemID of the
NOXE system associated with the Appendix E fuel curve.
Process/Category: Emissions Data Evaluation Report — Hourly Configuration Evaluation
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 303 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURAPP-7
Check Name:
Handle NOx Rate Summary Expected for ARP
Related Former Checks:
Applicability:
Description:
Specifications:
If CurrentHIEntityType is equal to "Unit", MPStackConfigForHourlyChecks is equal to "MS", and the
ExpectedSummaryValueNOxRateArray value fortius location is equal to false,
Locate a record in LocationProgramRecordsByHourAndLocation where:
1) ProgramCode is equal to 'ARP', and
2) Class is equal to 'PI' or 'P2'.
if found,
Set ExpectedSummaryValueNOxRateArray for this location to true
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report — Hourly Configuration Evaluation
Environmental Protection Agency
Page 304 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Category:
Hourly Calculated Data
Environmental Protection Agency
Page 305 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURCV-1
Check Name:
Calculate Percent H20
Related Former Checks:
Applicability:
Description:
Validation Tables:
Hourly Emissions Tolerances (Cross Check Table)
Specifications:
if (H20 Method Code = "MWD" AND Current DHV Record ModcCode in set {01, 02, 03, 04, 53, 54})
if (H20 CEM Equation Code == "F-31")
if (Current DHV Record Valid == true AND 02 Wet Calculated Adjusted Value is not null AND 02 Dry Calculated
Adjusted Value is not null)
H20 DHV Calculated Adjusted Value = ((02 Dry Calculated Adjusted Value - 02 Wet Calculated Adjusted
Value) * 100.0 ) / 02 Dry Calculated Adjusted Value, ROUNDED to one decimal place.
H20 Cone Tolerance = Lookup Tolerance from Cross-Check Table "Hourly Emissions Tolerances" where
Parameter = "H20" AND
UOM = "PCT"
If (Derived Hourly Adjusted Value Status == true AND ABS(H20 DHV Calculated Adjusted Value - Current
DHV Record. A dj u s t ed H o u r ly Va 1 ue) > H20 Cone Tolerance)
return result A
else
return result B
else if (H20 CEM Equation Code == "M-1K")
if (Derived Hourly Adjusted Value Status == true)
H20DHV Calculated Adjusted Value = Current DHV Record. Ad} ustedHourly Value
else
return result B
else if (H20 Method Code = "MDF" AND Current DHV Record ModcCode == "40")
H20 DHV Calculated Adjusted Value = H20 Default Value
else
H20 DHV Calculated Adjusted Value = Current DHV Calculated Adjusted Value
Results:
Result
A
Response
The AdjustedHourly Value reported in the DHV record for [param] is inconsistent with
the recalculated value.
The AdjustedHourly Value in the DHV record for [param] could not be recalculated due
to errors listed above.
Severity
Critical Error Level 1
B
Informational Message
Usage:
1 Process/Category: Emissions Data Evaluation Report H20 Calculation Verification
Environmental Protection Agency
Page 306 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURCV-3
Check Name: Determine Diluent Cap and Moisture for C02 Concentration Calculation Verification
Related Former Checks:
Applicability:
Description:
Specifications:
if (C()2 Cone CEM Equation Code == "F-14B")
If (H20 Method Code == "MWD" AND H20 Derived Hourly Checks Needed == true AND H20 DHV Calculated Adjusted
Value is not null)
Calculated Moisture for C02C = H20 DHV Calculated Adjusted Value
else if (H20 Method Code in set {MMS, MTB } AND H20 Monitor Hourly Checks Needed == true AND H20 MHV Calculated
Adjusted Value is not null)
Calculated Moisture for C02C = H20 MHV Calculated Adjusted Value
else if (H20 Method Code == "MDF" AND H20 Derived Hourly Checks Needed == true AND H20 DHV Calculated Adjusted
Value is not null)
Calculated Moisture for C02C = H20 DHV Calculated Adjusted Value
else if (H20 Method Code == "MDF" AND H20 Derived Hourly Checks Needed == false AND H20 Default Value is not null)
Calculated Moisture for C02C = H20 Default Value
if (Use 02 Diluent Cap for Co2 Cone Calc == true)
02XCount = # of active MonitoringDefault records for location where
ParameterCode = '02X' AND DefaultPurposeCode = 'DC' AND
FuelCode = 'NFS'
if (02X Count > 1)
return result A
else if (02XCount == 0)
return result B
else if MonitoringDefaultDefaultValue <= 0
return result C
else
Calculated Diluent for C02C = MonitoringDefaultDefaultValue
else
case (CO2 Cone CEM Equation Code)
"F-14A":
Calculated Diluent for C02C = 02 Drv Calculated Adjusted Value
"F-14B":
Calculated Diluent for C02C = 02 Wet Calculated Adjusted Value
Results:
Result Response
A You reported more than one diluent cap default record for 02X in your monitoring plan
that was active during current hour.
B You did not report a default record for 02X in your monitoring plan that was active
during the current hour. Please note that the use of a diluent cap to calculate C02
concentration is only applicable to legacy data.
C The DefaultValue reported in the active Default record for 02X in your monitoring
plan is invalid. The value must be greater than 0.
Usage:
1 Process/Category: Emissions Data Evaluation Report C02 Concentration Calculation Verification
Seventy
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 307 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURCV-4
Check Name:
Related Former Checks:
Calculate C02 Concentration
Applicability:
Description:
Specifications:
If {CurrentDHVRecord.ModcCode in set {01, 02, 03, 04, 53, 54})
C02 Cone Tolerance = Lookup Tolerance from Cross-Check Table "Hourly Emissions Tolerance" where
Parameter = "C02C" AND
UOM = "PCT"
case (CO 2 Cone CEM Equation Code)
"F-14A":
If {Current DHV Record Valid == true AND Calculated Diluentfor C02C is not null AND Valid FC Factor
Exists == true AND Valid FD Factor == true)
C02C DHV Calculated Adjusted Value = 100 * {Current Hourly Op Record.FcFactor /Current Hourly
Op Record. FdFactor) * [(20.9 - Calculated Diluent for C02C) / 20.9 ], and round the result to 1 decimal
place.
If {C02C DHV Calculated Adjusted Value < 0)
C02C DHV Calculated Adjusted Value = 0
If {Derived Hourly Adjusted Value Status == true AND ABS(CY/2C DHV Calculated Adjusted Value -
Current /)//K/?6'cwY/.AdjustcdHourly Value) > C02 Cone Tolerance)
return result A
else
return result B
"F-14B":
If {Current DHV Record Valid == true AND Calculated Diluentfor C02C is not null AND Valid FC Factor
Exists == true AND Valid FD Factor Exists == true AND Calculated Moisture for C02C is not null)
C02C DHV Calculated Adjusted Value = [100/20.9] * {Current Hourly Op Record.FcFactor /Current
Hourly Op Record. FdFactor) * [20.9 * ((100 - Calculated Moisture for C02C)/100) - Calculated
Diluentfor C02C ], and round the result to 1 decimal place.
If {C02C DHV Calculated Adjusted Value < 0)
C02C DHV Calculated Adjusted Value = 0
If {Derived Hourly Adjusted Value Status == true AND ABS{C02CDHV Calculated Adjusted Value-
Current /)//K/?6'cwY/.AdjustcdHourly Value) > C02 Cone Tolerance)
return result A
else
return result B
Otherwise
return result B
else
C02C DHV Calculated Adjusted Value = Current DHV Calculated Adjusted Value
Environmental Protection Agency
Page 308 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result Response Severity
A The AdjustedHourly Value reported in the DH V record for [param] is inconsistent with Critical Error Level 1
the recalculated value.
B The AdjustedHourly Value in the DHV record for [param] could not be recalculated due Informational Message
to errors listed above.
Usage:
1 Process/Category: Emissions Data Evaluation Report C02 Concentration Calculation Verification
Environmental Protection Agency
Page 309 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURCV-6
Check Name: Determine Diluent Cap and Moisture for Heat Input Calculation Verification
Related Former Checks:
Applicability:
Description:
Specifications:
If {Heat Input Method Code == "CEM")
if {Heat Input Equation Code in set {F-16, F-17, F-18}
ff {H20 Method Code == "MWD" AND H20 Derived Hourly Checks Needed == true AND H20 DHV Calculated
Adjusted Value is not null)
Calculated Moisture for HI = H20 DHV Calculated Adjusted Value
else if {H20 Method Code in set {MMS, MTB } AND H20 Monitor Hourly Checks Needed == true AND H20MHV
Calculated Adjusted Value is not null)
Calculated Moisture for HI = H20 MHV Calculated Adjusted Value
else if {H20 Method Code == "MDF" AND H20 Derived Hourly Checks Needed == true AND H20 DHV Calculated
Adjusted Value is not null)
Calculated Moisture for HI = H20 DHV Calculated Adjusted Value
else if {H20 Method Code == 'MDF" AND H20 Derived Hourly Checks Needed == false AND H20 Default Value is
not null)
Calculated Moisture for HI = H20 Default Value
if {Heat Input Equation Code = "F-15" OR Heat Input Equation Code = "F-16"
If (Current DHV Record. D ilucntCtipI ndictitor == 1)
C02N Count = # of active MonitoringDefault records for the location where
ParameterCode = 'C02N' AND DefaultPurposeCode = 'DC' AND
FuelCode = 'NFS'
if {CO2N Count > 1)
return result A
else if {C02N Count == 0)
return result B
else if MonitoringDefaultDefaultValue <= 0
return result C
else
Calculated Diluent For HI = MonitoringDefaultDefaultValue
else if {CO2 Cone Checks Needed for Heat Input == true)
if {Current C02 Cone Missing Data Monitor Hourly Record is not null)
Calculated Diluent for HI = C02C SD Calculated Adjusted Value
else
Calculated Diluent for HI = C02C MHV Calculated Adjusted Value
else if {Heat Input Equation Code == "F-17" OR Heat Input Equation Code == "F-18")
if (Current DH V Record.D i 1 lie ntCap I ndicato r == 1)
02X Count = # of active MonitoringDefault records for the location where
ParameterCode = '02X' AND DefaultPurposeCode = 'DC' AND
FuelCode = 'NFS'
if {02XCount > 1)
return result D
else if {02XCount == 0)
return result E
else if MonitoringDefaultDefaultValue <= 0
return result F
else
Calculated Diluent For HI = MonitoringDefaultDefaultValue
else if {Heat Input Equation Code = "F-17" AND 02 Wet Checks Needed for Heat Input == true)
Environmental Protection Agency
Page 310 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
if {Current 02 Wet Missing Data Monitor Hourly Record is not null)
Calculated Diluent for HI = 02C SD Calculated Adjusted Value
else
Calculated Diluent for HI = 02 Wet Calculated Adjusted Value
else if {Heat Input Equation Code == "F-18" AND 02 Dry Checks Needed for Heat Input == true)
if {Current 02 Dry Missing Data Monitor Hourly Record is not null)
Calculated Diluent for HI = 02C SD Calculated Adjusted Value
else
Calculated Diluent for HI = 02 Dry Calculated Adjusted Value
Result Response Severity
A You reported more than one diluent cap default record for C02N in your monitoring Critical Error Level 1
plan that was active during the current hour.
B You did not report an active C02N diluent cap default record in your monitoring plan Critical Error Level 1
for the hour. The use of the diluent cap to calculate HI is only applicable for legacy
data.
C The DefaultValue reported in the active Default record for C02N in your monitoring Critical Error Level 1
plan is invalid. The value must be greater than 0.
D You reported more than one diluent cap default record for 02X in your monitoring plan Critical Error Level 1
that was active during current hour.
E You did not report a default record for 02X in your monitoring plan that was active Critical Error Level 1
during the current hour. Please note that the use of a diluent cap to calculate HI is only
applicable to legacy data.
F The DefaultValue reported in the active Default record for 02X in your monitoring Critical Error Level 1
plan is invalid. The value must be greater than 0.
Usage:
1 Process/Category: Emissions Data Evaluation Report Heat Input Calculation Verification
Environmental Protection Agency
Page 311 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURCV-7
Check Name: Calculate Heat Input
Related Former Checks:
Applicability:
Description:
Validation Tables:
Hourly Emissions Tolerances (Cross Check Table)
Specifications:
if (Derived Hourly Adjusted Value Status == true AND Current Hourly Op Ttecwrf.OperatingTime is between 0 and 1 (inclusive))
Heat Input Total Reported Value = Current /)//K/?6'cwY/.AdjustcdHourly Value * Current Hourly Op Record.Opcrat ingTime.
if (Current Month is not April OR Annual Reporting Requirement == true)
if {Rpt Period HI Reported Accumulator Array for this location is not null)
if {Rpt Period HI Reported Accumulator Array >= 0)
Rpt Period HI Reported Accumulator Array for this location = Rpt Period HI Reported Accumulator
Array for this location + Heat Input Total Reported Value
else
Rpt Period HI Reported Accumulator Array for this location = Heat Input Total Reported Value
if {Current Entity Type == "Unit" AND Unit HeatlnputTimesOpTime Accumulator >= 0)
Unit HeatlnputTimesOpTime Accumulator = Unit HeatlnputTimesOpTime Accumulator + Heat Input Total Reported
Value
else
if {Current Month is not April OR Annual Reporting Requirement == true)
Rpt Period HI Reported Accumulator Array for this location = -1
if {Current Entity Type== "Unit")
Unit HeatlnputTimesOpTime Accumulator = -1
Total Heat Input from Fuel Flow = null
If {Heat Input Method Code== "CEM")
case {Heat Input Equation Code)
= "F-15":
If {Current DHVRecord Valid == true AND Calculated Diluent for HI is not null AND Valid FC Factor Exists
== true AND FLOW Calculated Adjusted Value is not null)
HI Calculated Adjusted Value= {FLOW Calculated Adjusted Value * Calculated Diluent for Heat
Input) / {Current Hourly Op RecordFcF&ctox * 100.0), and round the result to 1 decimal place.
else
return result A
= "F-16":
If {Current DHV Record Valid == true AND Calculated Diluentfor HI is not null AND Valid FC Factor Exists
== true AND FLOW Calculated Adjusted Value is not null AND Calculated Moisturefor HI is not null)
HI Calculated Adjusted Value= [FLOW Calculated Adjusted Value * (100 - Calculated Moisture for
HI) * Calculated Diluent for HI ] / (10,000 * Current Hourly Op Record. FcFactor), and round the result
to 1 decimal place.
else
return result A
= "F-17":
If {Current DHV Record Valid == true AND Calculated Diluentfor HI is not null AND Valid FD Factor Exists
Environmental Protection Agency
Page 312 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
== true AND FLOW Calculated Adjusted Value is not null AND Calculated Moisturefor HI is not null)
HI Calculated Adjusted Value = [FLOW Calculated Adjusted Value * (1 / Current Hourly Op
Record. FdFactor)* [ 0.209 * (100 - Calculated Moisture for HI) - Calculated Diluent for HI] / 20.9) ],
and round the result to 1 decimal place.
else
return result A
= "F-18":
If (Current DHVRecord Valid == true AND Calculated Diluent for HI is not null AND Valid FD Factor Exists
== true AND FLOW Calculated Adjusted Value is not null AND Calculated Moisturefor HI is not null)
HI Calculated Adjusted Value = (FLOW Calculated Adjusted Value *[100 - Calculated Moisture for
HI\ * [20.9 - Calculated Diluent for HI] ) / (2090 * Current Hourly Op Record.FdFactor), and round the
result to 1 decimal place.
else
return result A
= All Other Equation Codes:
return result A
if no result
if (HI Calculated Adjusted Value is less than 1 AND Legacy Data Evaluation == false)
HI Calculated Adjusted Value = 1
Apportionment Calc HI Array at this Location = HI Calculated Adjusted Value
if (MPStack Configfor Hourly Checks == 'MS")
Config Heatlnput Accumulator = Config Heatlnput Accumulator + HI Calculated Adjusted Value
if result A
Apportionment Calc HI Array at this Location = -1
Config HeatlnputTimesOpTime Accumulator = -1
if (Current Month is not April OR Annual Reporting Requirement == true)
Rpt Period HI Calculated Accumulator Array for this location = -1
if (MP Stack Config for Hourly Checks == 'MS")
Config Heatlnput Accumulator = -1
else if (Heat Input App D Method Active for Hour == true)
if (HI App D Accumulator >= 0)
Total Heat Input from Fuel Flow = HI App D Accumulator
if (HI App D Accumulator >= 0 AND Current Hourly Op /?6'cw
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Rpt Period HI Calculated Accumulator Array for this location = -1
return result A
else if (Heat Input Method Code NOT in set {ADCALC, CALC})
HI Calculated Adjusted Value = Current DHV Calculated Adjusted Value
Apportionment Calc HI Array at this Location = HI Calculated Adjusted Value
If (HI Calculated Adjusted Value is not null)
If (Current Hourly Op Record.Ope rat i ngTi me is between 0 and 1 inclusive)
Heat Input Total Calculated Value = HI Calculated Adjusted Value * Current Hourly Op Record.OperatingTime.
if ( Config HeatlnputTimesOpTime Accumulator >= 0)
Config HeatlnputTimesOpTime Accumulator = Config HeatlnputTimesOpTime Accumulator + Heat Input
Total Calculated Value
if (Current Month is not April OR Annual Reporting Requirement == true)
if (Rpt Period HI Calculated Accumulator Array for this location is not null)
if (Rpt Period HI Calculated Accumulator Array for this location >= 0)
Rpt Period HI Calculated Accumulator Array for this location = Rpt Period HI Calculated
Accumulator Array for this location + Heat Input Total Calculated Value
else
Rpt Period HI Calculated Accumulator Array for this location = Heat Input Total Calculated Value
if (Current Month is April)
if (April HI Calculated Accumulator Array for this location is not null)
April HI Calculated Accumulator Array for this location = April HI Calculated Accumulator
Array for this location + Heat Input Total Calculated Value
else
April HI Calculated Accumulator Array for this location = Heat Input Total Calculated Value
else
Config HeatlnputTimesOpTime Accumulator = -1
if (Current Month is not April OR Annual Reporting Requirement == true)
Rpt Period HI Calculated Accumulator Array for this location = -1
If (Derived Hourly Adjusted Value Status == true)
If (Heat Input Method Code in set {CEM, AD})
if (HI Calculated Adjusted Value is equal to 1 AND Current DHV Record. Adj ustedHourly Value is less than 1
AND Current DHV Record.MODCCode is not equal to "26" and Legacy Data Evaluation == false)
return result C
else
Heat Input Tolerance = Lookup Tolerance from Cross-Check Table "Hourly Emissions Tolerances" where
Parameter = "HI" AND
UOM = "MMBTUHR"
if (A B S( Current DHV Record. Adj ustedHourly V al lie - HI Calculated Adjusted Value) > Heat Input
Tolerance)
return result B
else if (Apportionment Calc HI Array at this Location is greater than or equal to 0) \\ ADCALC
If (Current Hourly Op Record.OperatingTime is between 0 and 1 inclusive)
Environmental Protection Agency
Page 314 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Heat Input Total Calculated Value = Apportionment Calc HI Array at this Location * Current Hourly Op
Record. OperatingTime.
if ( Config HeatlnputTimesOpTime Accumulator >= 0)
Config HeatlnputTimesOpTime Accumulator = Config HeatlnputTimesOpTime Accumulator + Heat Input
Total Calculated Value
else
Config HeatlnputTimesOpTime Accumulator = -1
else if {Heat Input Method Code not in set {ADCALC, CALC})
Apportionment Calc HI Array at this Location = -1
Config HeatlnputTimesOpTime Accumulator = -1
if {Current Month is not April OR Annual Reporting Requirement == true)
Rpt Period HI Calculated Accumulator Array for this location = -1
Results:
Result Response Severity
A The AdjustedHourly Value in the DHV record for [param] could not be recalculated due Informational Message
to errors listed above.
B The AdjustedHourly Value reported in the DHV record for [param] is inconsistent with Critical Error Level 1
the recalculated value.
C You reported in AdjustedHourly Value of less than 1 in the DHV record for [param]. Critical Error Level 1
You must report a minimum heat input of 1 and a MODCCode of "26".
Usage:
1 Process/Category: Emissions Data Evaluation Report Heat Input Calculation Verification
Environmental Protection Agency
Page 315 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURCV-9
Check Name: Calculate S02 Mass Emissions
Related Former Checks:
Applicability:
Description:
Validation Tables:
Hourly Emissions Tolerances (Cross Check Table)
Specifications:
if (Derived Hourly Adjusted Value Status == true AND Current Hourly Op Ttecwrf.OperatingTime is between 0 and 1 (inclusive))
S02 Total Reported Value = Current DHV Record .k&\\iS{cAHom\\Va 1 lie * Current Hourly Op Record.OpcratingTime.
if (Rpt Period S02 Mass Reported Accumulator Array for this location is not null)
if {Rpt Period S02 Mass Reported Accumulator Array for this location >= 0)
Rpt Period S02 Mass Reported Accumulator Array for this location = Rpt Period S02 Mass Reported
Accumulator Array for this location + S02 Total Reported Value
else
Rpt Period S02 Mass Reported Accumulator Array for this location = SO2 Total Reported Value
else
Rpt Period S02 Mass Reported Accumulator Array for this location = -1
If (S()2 CEM Method Active for Hour == true)
if (SO2 Equation Code== "F-l")
If {Current DHV Record Valid == true AND S02C Calculated Adjusted Valuers not null AND FLOW Calculated
Adjusted Value is not null)
SO2 Calculated Adjusted Value = 0.000000166 * S02C Calculated Adjusted Value * FLOW Calculated
Adjusted Value, ROUNDED to one decimal place.
else
Rpt Period S02 Mass Calculated Accumulator Array for this location = -1
return result A
else if (SO2 Equation Code== "F-2")
If {Current DHV Record Valid == true AND S02C Calculated Adjusted Value is not null AND FLOW Calculated
Adjusted Value is not null AND Calculated Moisture for S02 is not null)
SO2 Calculated Adjusted Value = 0.000000166 * S02C Calculated Adjusted Value * FLOW Calculated
Adjusted Value * (100.0 - Calculated Moisture for S02) /100.0, ROUNDED to one decimal place.
else
Rpt Period S02 Mass Calculated Accumulator Array for this location = -1
return result A
else
Rpt Period S02 Mass Calculated Accumulator Array for this location = -1
return result A
else if (SO 2 F23 Method Active for Hour == true)
If {Current DHV Record Valid == true AND F23 Default Value is not null AND HI Calculated Adjusted Value is not
null)
SO2 Calculated Adjusted Value = F23 Default Value * HI Calculated Adjusted Value, rounded to one decimal
place.
Environmental Protection Agency
Page 316 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
else
Rpt Period S02 Mass Calculated Accumulator Array for this location = -1
return result A
else if (SO 2 App D Method Active for Hour == true)
if (SO2 App D Accumulator >= 0 AND Current Hourly Op Record.Opcrat ingTime is between 0 and 1 (inclusive))
SO2 Calculated Adjusted Value = S02 App D Accumulator / Current Hourly Op Record.OperatingTime.
If (Hourly Fuel Flow Count For Gas is greater than 0)
Round SO2 Calculated Adjusted Value to four decimal places.
else
Round SO2 Calculated Adjusted Value to one decimal place.
else
Rpt Period S02 Mass Calculated Accumulator Array for this location = -1
return result A
else
S02 Calculated Adjusted Value = Current DHV Calculated Adjusted Value
If (S()2 Calculated Adjusted Value is not null)
If {Current Hourly Op Record.OperatingTime is between 0 and 1 inclusive)
S02 Total Calculated Value = S02 Calculated Adjusted Value * Current Hourly Op Record.OperatingTime
if (Rpt Period S02 Mass Calculated Accumulator Array for this location is not null)
if (Rpt Period S02 Mass Calculated Accumulator Array for this location >= 0)
Rpt Period S02 Mass Calculated Accumulator Array for this location = Rpt Period S02 Mass
Calculated Accumulator Array for this location + S02 Total Calculated Value
else
Rpt Period S02 Mass Calculated Accumulator Array for this location = S02 Total Calculated Value
else
Rpt Period S02 Mass Calculated Accumulator Array for this location = -1
If (Derived Hourly Adjusted Value Status == true)
S02 Tolerance = Lookup Tolerance from Cross-Check Table "Hourly Emissions Tolerances" where
Parameter = "S02" AND
UOM = "LBHR"
if (A B S(Current I)H V Record. Adj ustcdHourly Va luc - SO2 Calculated Adjusted Value) > S02 Tolerance)
return result B
else
Rpt Period S02 Mass Calculated Accumulator Array for this location = -1
Results:
Result Response Severity
A The AdjustedHourly Value in the DHV record for [param] could not be recalculated due Informational Message
to errors listed above.
B The AdjustedHourly Value reported in the DHV record for [param] is inconsistent with Critical Error Level 1
the recalculated value.
Usage:
1 Process/Category: Emissions Data Evaluation Report S02 Calculation Verification
Environmental Protection Agency
Page 317 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURCV-12
Check Name: Determine Diluent Cap, Moisture, and NOXC for NOx Rate Calculation Verification
Related Former Checks:
Applicability:
Description:
Specifications:
If 0Current NOx Rate Method Code == "CEM" AND Current DHV Record ModcCode in set {0 \ 02, 03, 04, 14, 22, 53, 54})
if (NOx Cone Monitor Hourly Count == 1 AND Current NOx Cone Monitor Hourly Record.UnadjustedHourly Value is not null)
NOx Cone for NOx Rate Calculation = Current NOx Cone Monitor Hourly Record. U nadj ustedHourly Value
else
NOx Cone for NOx Rate Calculation = null
if (NOx Rate Equation Code inset {19-3, 19-3D, 19-4, 19-5, 19-8, 19-9})
ff (H20 Method Code == "MWD" AND H20 Derived Hourly Checks Needed == true AND H20 DHV Calculated
Adjusted Value is not null)
Calculated Moisture for NOXR = H20 DHV Calculated Adjusted Value
else if (H20 Method Code in set {MMS, MTB} AND H20 Monitor Hourly Checks Needed == true AND H20MHV
Calculated Adjusted Value is not null)
Calculated Moisture for NOXR = H20 MHV Calculated Adjusted Value
else if (H20 Method Code == "MDF" AND H20 Derived Hourly Checks Needed == true AND H20 DHV Calculated
Adjusted Value is not null)
Calculated Moisture for NOXR = H20 DHV Calculated Adjusted Value
else if (H20 Method Code == 'MDF" AND H20 Derived Hourly Checks Needed == false AND H20 Default Value is
not null)
Calculated Moisture for NOXR = H20 Default Value
if (NOx Rate Equation Code in set {19-3D, 19-5D} OR Current DHV Record ModcCode == 14)
ff (NOx Rate Equation Code in set {F-5, 19-1, 19-2, 19-3, 19-3D, 19-4, 19-5, 19-5D})
02 Monitor Default Matches = count of # active MonitoringDefaultData records for location where
MonitoringDefaultData.ParameterCode = "02X" AND MonitoringDefaultData.DefaultPurposeCode =
"DC" AND MonitoringDefaultData.FuelCode = "NFS"
if 02 Monitor Default Matches > 1
return result A
else if 02 Monitor Default Matches = 0
return result B
else
02 Monitor Default Record = the single matched record
if ( 02 Monitor Default Record.DefaultValue is NULL OR 02 Monitor Default Record.DefaultValue <=
0)
return result C
else
Calculated Diluent for NOXR = 02 Monitor Default Record .DefaultValue
else if (NOx Rate Equation Code inset {F-6, 19-6, 19-7, 19-8, 19-9})
C02 Monitor Default Matches = count of # active MonitoringDefaultData records for location where
MonitoringDefaultData.ParameterCode = "C02N" AND MonitoringDefaultData.DefaultPurposeCode =
"DC" AND MonitoringDefaultData.FuelCode = "NFS"
if C02 Monitor Default Matches > 1
return result D
else if C02 Monitor Default Matches = 0
return result E
Environmental Protection Agency
Page 318 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
CO2 Monitor Default Record = the single matched record
if (CO 2 Monitor Default Record DefaultValue is NULL OR C02 Monitor Default Record.DefaultValue
<=0)
return result F
else
Calculated Diluent for NOx Rate = C02 Monitor Default Record. Default Value
If (NOx Rate Equation Code in set {F-5, 19-1, 19-4} AND 02 Dry Checks Neededfor NOx Rate Calc == true)
Calculated Diluent for NOx Rate = 02 Dry Calculated Adjusted Value
else if (NOxRate Equation Code in set {19-2. 19-3, 19-5} AND ()2 Wet Checks Neededfor NOx Rate Calc == true)
Calculated Diluent for NOx Rate = 02 Wet Calculated Adjusted Value
else if (NOxRate Equation Code inset {F-6, 19-6, 19-7, 19-8, 19-9} AND CO 2 Cone Monitor Hourly Checks Needed
== true)
Calculated Diluent for NOx Rate = C02C MHV Calculated Adjusted Value
Results:
Result
A
B
C
D
E
F
Usage:
1
Severity
Response
You reported more than one diluent cap default record for 02X in your monitoring plai
that was active during current hour.
You did not report a default record for 02X in your monitoring plan that was active
during current hour.
The DefaultValue reported in the active Default record for 02X in your monitoring
plan is invalid. The value must be greater than 0.
You reported more than one diluent cap default record for C02N in your monitoring
plan that was active during the current hour.
You did not report an active C02N diluent cap default record in your monitoring plan
for the hour.
The DefaultValue reported in the active Default record for C02N in your monitoring
plan is invalid. The value must be greater than 0.
Process/Category: Emissions Data Evaluation Report NOx Emissions Rate Calculation Verification
Critical
Error Level 1
Critical
Error Level 1
Critical
Error Level 1
Critical
Error Level 1
Critical
Error Level 1
Critical
Error Level 1
Environmental Protection Agency
Page 319 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURCV-13
Check Name:
Calculate Unadjusted NOx Emissions Rate
Related Former Checks:
Applicability:
Description:
Validation Tables:
Hourly Emissions Tolerances (Cross Check Table)
Specifications:
NOXR Calculated Unadjusted Value = null
Derived Hourly Unadjusted Calculation Status = false
If {Current NOx Rate Method Code == "CEM" AND Current I)HV Record. ModcCodc in set {01, 02, 03, 14, 22, 53})
If (Current DHV Record.SxsicmTxpcCodc == "NOX")
RA TA Status Required = true
case (NOx Rate Equation Code)
"19-1" or "F-5":
If {Current DHV Record Valid == true AND Calculated Diluent for NOXR is not null AND NOX Cone for NOx Rate
Calc is not null AND Valid FD Factor Exists == true)
if {Calculated Diluent for NOXR == 20.9)
return result A
else
NOXR Calculated Unadjusted Value = 0.0000001194 * NOX Cone for NOx Rate Calc * Current
Hourly Op Record.FdF actor * [20.9 / (20.9 - Calculated Diluent for NOXR)], rounded to 3 decimal
places.
else
return result B
"19-2":
Moisture Fraction = null
BWA Default Record Count = count active MonitoringDefaultData Records for the location where ParameterCd = 'BWA'
If {BWA Default Record Count == 0)
Moisture Fraction = 0.027
else If {BWA Default Record Count == 1 AND MonitorDefaultData.DefaultValue > 0 AND
MonitorDefaultData.DefaultValue < 1)
Moisture Fraction = MonitorDefaultData.DefaultValue
else
return result D
If {Current DHV Record Valid == true AND Calculated Diluent for NOXR is not null AND NOX Cone for NOx Rate
Calc is not null AND Valid FW Factor Exists == true AND Moisture Fraction is not null)
if {Calculated Diluent for NOXR == 20.9 * (1 - Moisture Fraction))
return result A
else
NOXR Calculated Unadjusted Value = 0.0000001194 * NOX Cone for NOx Rate Calc * Current
Hourly Op Record. FwFac to r * [20.9 / (20.9 *(1 - Moisture Fraction) - Calculated Diluent for NOXR)],
rounded to 3 decimal places.
else
return result B
Environmental Protection Agency
Page 320 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
"19-3":
If (Current DHV Record Valid == true AND Calculated Diluent for NOXR is not null AND NOX Cone for NOx Rate
Calc is not null AND Valid FD Factor Exists == true AND Calculated Moisture for NOXR is not null)
if (Calculated Diluent for NOXR == 20.9*(100 - Calculated Moisture for NOXR) / 100 )
return result A
else
denom = (20.9*(100 - Calculated Moisture for NOXR )/100 - Calculated Diluent for NOXR)
NOXR Calculated Unadjusted Value = 0.0000001194 * NOX Cone for NOx Rate Calc * Current
Hourly Op RecordFdFactor * [20.9 /denom ], rounded to 3 decimal places.
else
return result B
"19-3D":
If (Current DHV Record Valid == true AND Calculated Diluent for NOXR is not null AND NOX Cone for NOx Rate
Calc is not null AND Valid FD Factor Exists == true AND Calculated Moisture for NOXR is not null)
h2oFactor = (100 - Calculated Moisture for NOXR) / 100.0
denomTerm = (20.9 * h2oFactor) - (Calculated Diluent for NOXR * h2oFactor)
if ( denomTerm == 0)
return result A
else
NOXR Calculated Unadjusted Value = 0.0000001194 * NOX Cone for NOx Rate Calc * Current
Hourly Op Record.¥AFncXor * 20.9 / denomTerm, rounded to 3 decimal places.
else
return result B
"19-4":
If (Current DHV Record Valid == true AND Calculated Diluent for NOXR is not null AND NOX Cone for NOx Rate
Calc is not null AND Valid FD Factor Exists == true AND Calculated Moisture for NOXR is not null)
if ( Calculated Diluent for NOXR == 20.9 OR Calculated Moisture for NOXR == 100)
return result A
else
NOXR Calculated Unadjusted Value = 0.0000001194 * NOX Cone for NOx Rate Calc * Current
Hourly Op Record. FdFac to r / [ (100 - Calculated Moisture for NOXR) / 100.0] * (20.9 / (20.9 -
Calculated Diluent for NOXR)), rounded to 3 decimal places.
else
return result B
"19-5":
If (Current DHV Record Valid == true AND Calculated Diluent for NOXR is not null AND NOX Cone for NOx Rate
Calc is not null AND Valid FD Factor Exists == true AND Calculated Moisture for NOXR is not null)
if (Calculated Moisture for NOXR == 100)
return result A
else
H20Term = (100 - Calculated Moisture for NOXR) / 100.0
denom = 20.9 - Calculated Diluent for NOXR / H20Term
if (denom == 0)
return result A
Environmental Protection Agency
Page 321 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
else
NOXR Calculated Unadjusted Value = 0.0000001194 * NOX Cone for NOx Rate Calc'
Current Hourly Op Record.FdFactor / denom, rounded to 3 decimal places.
else
return result B
"19-5D":
If (Current DHV Record Valid == true AND Calculated Diluent for NOXR is not null AND NOX Cone for NOx Rate
Calc is not null AND Valid FD Factor Exists == true)
if (Calculated Diluent for NOXR == 20.9)
return result A
else
NOXR Calculated Unadjusted Value = 0.0000001194 * NOX Cone for NOx Rate Calc * Current
Hourly ()p Record. FdFactor * 20.9/ (20.9 - Calculated Diluent for NOXR), rounded to 3 decimal
places.
else
return result B
"19-6" or "19-7" or "F-6":
If (Current DHV Record Valid == true AND Calculated Diluent for NOXR is not null AND NOX Cone for NOx Rate
Calc is not null AND Valid FC Factor Exists == true)
if (Calculated Diluent for NOXR ==0.0)
return result A
else
NOXR Calculated Unadjusted Value = 0.0000001194 * NOX Cone for NOx Rate Calc * Current
Hourly Op Record.FcF actor * 100.0 / Calculated Diluent for NOXR, rounded to 3 decimal places.
else
return result B
"19-8":
If (Current DHV Record Valid == true AND Calculated Diluent for NOXR is not null AND NOX Cone for NOx Rate
Calc is not null AND Valid FC Factor Exists == true AND Calculated Moisture for NOXR is not null)
if (Calculated Diluent for NOXR == 0.0 OR Calculated Moisture for NOXR == 100)
return result A
else
NOXR Calculated Unadjusted Value = 0.0000001194 * NOX Cone for NOx Rate Calc * Current
Hourly Op Record. FcFactor / [ (100 - Calculated Moisture for NOXR) / 100.0] * (100.0 / Calculated
Diluentfor NOXR), rounded to 3 decimal places.
else
return result B
"19-9":
If (Current DHV Record Valid == true AND Calculated Diluent for NOXR is not null AND NOX Cone for NOx Rate
Calc is not null AND Valid FC Factor Exists == true AND Calculated Moisture for NOXR is not null)
if (Calculated Diluent for NOXR ==0.0)
return result A
else
H20Term = (100 - Calculated Moisture for NOXR) / 100.0
C02Term = 100.0 / Calculated Diluent for NOXR
Environmental Protection Agency
Page 322 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
NOXR Calculated Unadjusted Value = 0.0000001194 * NOX Cone for NOx Rate Calc * Current
Hourly Op Record.FcFactor * H20Term * C02Term, rounded to 3 decimal places.
else
return result B
If (Derived Hourly Unadjusted Value Status == true AND NOXR Calculated Unadjusted Value is not null)
Tolerance = Lookup Tolerance from Cross-Check Table "Hourly Emissions Tolerances" where
Parameter = "NOXR" AND
UOM = "LBMMBTU"
if (ABS(Current I)HVRecord.UnadjustcdHourly Value - NOXR Calculated Unadjusted Value) > Tolerance)
return result C
else
Derived Hourly Unadjusted Calculation Status = true
else if (Current NOx Rate Method Code == "PEM" AND Current I)HVRecord. ModcCodc in set {01, 02, 03})
If (CurrentDHVRecord.SystemTypeCode == "NOXP")
RA TA Status Required = true
If Current I)H V Record. U nadj ustcdHourly Va 1 uc >= 0
NOXR Calculated Unadjusted Value = Current /)//K/?6'cwy/.U nadj ustcdHourly Value
Derived Hourly Unadjusted Calculation Status = true
else if (Current NOx Rate Method Code == "AE")
If (App E Constant Fuel Mix == true)
NOXR Calculated Adjusted Value = App E Calculated NOx Rate for Source
else
NOXR Calculated Adjusted Value = Current DHV Calculated Adjusted Value
if (Current NOx Rate Method Code in set {CEM, PEM} AND Current DHV Record. ModcCode == 21)
If (Current DHV Record. SystemTypeCode in set {NOX, NOXP})
RA TA Status Required = true
Results:
Result
B
C
D
Response
The NOx emission rate could not be recalculated, because the diluent and/or moisture
value would result in division by zero. You should report an MODC of 14 indicating
the use of a diluent cap to prevent this.
The UnadjustedHourly Value in the DHV record for [param] could not be recalculated
due to errors listed above.
The UnadjustedHourlyValue reported in the DHV record for [param] is inconsistent
with the recalculated value.
You did not report a single valid MonitorDefault record for ParameterCode BWA for
the hour.
Severity
Critical Error Level 1
Informational Message
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 323 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
Usage:
1 Process/Category: Emissions Data Evaluation Report NOx Emissions Rate Calculation Verification
Environmental Protection Agency
Page 324 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURCV-15
Check Name:
Determine Moisture for NOx Mass Calculation Verification
Related Former Checks:
Applicability:
Description:
Specifications:
If {NOx Mass Monitor Method Code begins with "CEM")
If (NOx Mass Equation Code== "F-26B")
If (H20 Method Code == "MWD" AND H20 Derived Hourly Checks Needed == true AND H20 DHV Calculated
Adjusted Value is not null)
Calculated Moisture for NOX = H20 DHV Calculated Adjusted Value
else if (H20 Method Code in set {MMS, MTB} AND H20 Monitor Hourly Checks Needed == true AND H20MHV
Calculated Adjusted Value is not null)
Calculated Moisture for NOX = H20 MHV Calculated Adjusted Value
else if (H20 Method Code == "MDF" AND H20 Derived Hourly Checks Needed == true AND H20 DHV Calculated
Adjusted Value is not null)
Calculated Moisture for NOX = H20 DHV Calculated Adjusted Value
else if (H20 Method Code == 'MDF" AND H20 Derived Hourly Checks Needed == false AND H20 Default Value is
not null)
Calculated Moisture for NOX = H20 Default Value
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report NOx Mass Rate Calculation Verification
Environmental Protection Agency
Page 325 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURCV-16
Check Name: Calculate NOx Mass Emissions
Related Former Checks:
Applicability:
Description:
Validation Tables:
Hourly Emissions Tolerances (Cross Check Table)
Specifications:
if (Derived Hourly Adjusted Value Status == true AND Current Hourly Op Ttecwrf.OperatingTime is between 0 and 1 (inclusive))
NOX Mass Total Reported Value = Current DHV Record. k&\us{cAHo\.tf\\V'c\\\iC * Current Hourly Op Ttecon/.OperatingTime.
if (Current Month is not April OR Annual Reporting Requirement == true)
if (Rpt Period NOX Mass Reported Accumulator Array for this location is not null)
if (Rpt Period NOX Mass Reported Accumulator Array fortius location >=0)
Rpt Period NOX Mass Reported Accumulator Array for this location = Rpt Period NOX Mass Reported
Accumulator Array for this location + NOX Mass Total Reported Value
else
Rpt Period NOX Mass Reported Accumulator Array for this location = NOX Mass Total Reported Value
else
if (Current Month is not April OR Annual Reporting Requirement == true)
Rpt Period NOX Mass Reported Accumulator Array for this location = -1
If (NOx Mass Monitor Method Code in set {CEM, NOXR, CEMNOXR})
if (NOx Mass Equation Code== "F-26A")
If (Current DHV Record Valid == true AND NOXC Calculated Adjusted Value is not null AND FLOW Calculated
Adjusted Value is not null)
NOX Calculated Adjusted Value = 0.0000001194 * NOXC Calculated Adjusted Value * Stack Flow Calculated
Adjusted Value, ROUNDED to one decimal place.
else
if (Current Month is not April OR Annual Reporting Requirement == true)
Rpt Period NOX Mass Calculated Accumulator Array for this location = -1
return result A
else if (NOXMass Equation Code== "F-26B")
If (Current DHV Record Valid == true AND NOXC Calculated Adjusted Value is not null AND FLOW Calculated
Adjusted Value is not null AND Calculated Moisture for NOX is not null)
NOX Calculated Adjusted Value= 0.0000001194 * NOXC Calculated Adjusted Value * FLOW Calculated
Adjusted Value * (100.0 - Calculated Moisture for NOX) /100.0, ROUNDED to one decimal place.
else
if (Current Month is not April OR Annual Reporting Requirement == true)
Rpt Period NOX Mass Calculated Accumulator Array for this location = -1
return result A
else if (NOXMass Equation Code== "F-24A")
if (Heat Input Method Code NOT in set {CALC, ADCALC})
If (Current DHV Record Valid == true AND NOXR Calculated Adjusted Value is not null
Environmental Protection Agency
Page 326 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
If (HI Calculated Adjusted Value is not null)
NOX Calculated Adjusted Value = NOXR Calculated Adjusted Value * HI Calculated Adjusted
Value, ROUNDED to one decimal place.
else
if {Current Month is not April OR Annual Reporting Requirement == true)
Rpt Period NOX Mass Calculated Accumulator Array for this location = -1
return result A
else
if {Current Month is not April OR Annual Reporting Requirement == true)
Rpt Period NOX Mass Calculated Accumulator Array for this location = -1
return result A
else
if {Current Month is not April OR Annual Reporting Requirement == true)
Rpt Period NOX Mass Calculated Accumulator Array for this location = -1
return result A
else
NOX Calculated Adjusted Value = Current DHV Calculated Adjusted Value
If {NOX Calculated Adjusted Value is not null)
If {Current Hourly Op Record.OperatingTime is between 0 and 1 inclusive)
NOxMass Total Calculated Value = NOX Calculated Adjusted Value * Current Hourly Op Record.Ope rat i ngTi me.
if {Current Month is not April OR Annual Reporting Requirement == true)
if {Rpt Period NOX Mass Calculated Accumulator Array for this location is not null)
if {Rpt Period NOX Mass Calculated Accumulator Array for this location >=0)
Rpt Period NOX Mass Calculated Accumulator Array for this location = Rpt Period NOX Mass
Calculated Accumulator Array for this location + NOX Mass Total Calculated Value
else
Rpt Period NOXMass Calculated Accumulator Array for this location = NOXMass Total Calculated
Value
if {Current Month is April)
if {April NOX Mass Calculated Accumulator Array for this location is not null)
April NOX Mass Calculated Accumulator Array fox this location = April NOX Mass Calculated
Accumulator Array for this location + NOXMass Total Calculated Value
else
April NOX Mass Calculated Accumulator Array for this location = NOX Mass Total Calculated
Value
else
if {Current Month is not April OR Annual Reporting Requirement == true)
Rpt Period NOX Mass Calculated Accumulator Array for this location = -1
If {Derived Hourly Adjusted Value Status == true AND Current DHV Method in set {CEM, NOXR, CEMNOXR})
NOX Tolerance = Lookup Tolerance from Cross-Check Table "Hourly Emissions Tolerances" where
Parameter = "NOX" AND
UOM = "LBHR"
if (ABS(C.'m/*/*6'«?/)//K/?6'cwY/.AdjustcdHourly Value - NOX Calculated Adjusted Value) > NOX Tolerance)
If {Legacy Data Evaluation == false)
return result B
else if {Current Hourly Op /Jafa.OpTime is greater than 0 and less than or equal to 1)
Environmental Protection Agency
Page 327 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
if (AB S( Current DHV Record. Adj ustcdHourly Value - NOX Calculated Adjusted Value) > NOX
Tolerance / Current Hourly ()p Record Opcrat ingTiinc)
return result B
else if {NOX Mass Equation CodeO "F-24A" OR Current DHV Record Valid == false OR NOXR Calculated Adjusted Value is null OR
Heat Input Method Code NOT in set {CALC, ADCALC})
if {Current Month is not April OR Annual Reporting Requirement == true)
Rpt Period NOX Mass Calculated Accumulator Array for this location = -1
Results:
Result Response Severity
A The AdjustedHourly Value in the DHV record for [param] could not be recalculated due Informational Message
to errors listed above.
B The AdjustedHourly Value reported in the DHV record for [param] is inconsistent with Critical Error Level 1
the recalculated value.
Usage:
1 Process/Category: Emissions Data Evaluation Report NOx Mass Rate Calculation Verification
Environmental Protection Agency
Page 328 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURCV-18
Check Name: Determine Diluent Cap and Moisture for C02 Mass Calculation Verification
Related Former Checks:
Applicability:
Description:
Specifications:
If (C02 Method Code == "CEM")
if (CO 2 Mass Equation Code== "F-2")
ff (H20 Method Code == "MWD" AND H20 Derived Hourly Checks Needed == true AND H20 DHV Calculated
Adjusted Value is not null)
Calculated Moisture for C02 = H20 DHV Calculated Adjusted Value
else if (H20 Method Code in set {MMS, MTB} AND H20 Monitor Hourly Checks Needed == true AND H20MHV
Calculated Adjusted Value is not null)
Calculated Moisture for C02 = H20 MHV Calculated Adjusted Value
else if (H20 Method Code == "MDF" AND H20 Derived Hourly Checks Needed == true AND H20 DHV Calculated
Adjusted Value is not null)
Calculated Moisture for C02 = H20 DHV Calculated Adjusted Value
else if (H20 Method Code == 'MDF" AND H20 Derived Hourly Checks Needed == false AND H20 Default Value is
not null)
Calculated Moisture for C02 = H20 Default Value
if (Use C02 Diluent Cap for C02 Mass Calc == true)
C02N Count = # of active MonitoringDefault records for location where
ParameterCode = 'C02N' AND DefaultPurposeCode = 'DC' AND
FuelCode = 'NFS'
if (C02N Count > 1)
return result A
else if (C02N Count == 0)
return result B
else if MonitoringDefaultDefaultValue <= 0
return result C
else
Calculated Diluent for C02 = MonitoringDefaultDefaultValue
else if (C02 Cone Derived Checks Needed == true)
Calculated Diluent for C02 = C02C DHV Calculated Adjusted Value
else if (CO2 Cone Checks Neededfor C02 Mass == true)
if (Current C02 Cone Missing Data Monitor Hourly Record is not null)
Calculated Diluent for C02 = C02C SD Calculated Adjusted Value
else
Calculated Diluent for C02 = C02C MHV Calculated Adjusted Value
Results:
Result
A
B
C
Response
Severity
You reported more than one diluent cap default record for C02N in your monitoring Critical Error Level 1
plan that was active during the current hour.
A DHV record indicates use of a diluent cap to calculate C02, but you did not report an Critical Error Level 1
active C02N default record in your monitoring plan for the hour. Please note that the
use of the diluent cap to calculate C02 is only applicable to legacy data.
The DefaultValue reported in the active Default record for C02N in your monitoring Critical Error Level 1
plan is invalid. The value must be greater than 0.
Environmental Protection Agency
Page 329 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
Usage:
1 Process/Category: Emissions Data Evaluation Report C02 Mass Rate Calculation Verification
Environmental Protection Agency
Page 330 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURCV-19
Check Name: Calculate C02 Mass Emissions
Related Former Checks:
Applicability:
Description:
Validation Tables:
Hourly Emissions Tolerances (Cross Check Table)
Specifications:
if (Derived Hourly Adjusted Value Status == true AND Current Hourly Op OperatingTime is between 0 and 1 (inclusive))
C02 Total Reported Value = Current /)//K/?6'cwY/.AdjustcdHourly Value * Current Hourly Op Record.Opcrat ingTime.
if (Rpt Period C02 Mass Reported Accumulator Array for this location is not null)
if {Rpt Period C02 Mass Reported Accumulator Array for this location >= 0)
Rpt Period C02 Mass Reported Accumulator Array for this location = Rpt Period C02 Mass Reported
Accumulator Array for this location + C02 Total Reported Value
else
Rpt Period C02 Mass Reported Accumulator Array for this location = CO 2 Total Reported Value
else
Rpt Period C02 Mass Reported Accumulator Array for this location = -1
ff (CX)2 Method Code == "CEM")
if (C02 Mass Equation Code== "F-ll")
If (Current DHV Record Valid == true AND Calculated Diluent for C02 is not null AND FLOW Calculated Adjusted
Value is not null)
CO 2 Calculated Adjusted Value = 0.00000057* Calculated Diluent for C02 * FLOW Calculated Adjusted
Value, ROUNDED to one decimal place.
else
Rpt Period C02 Mass Calculated Accumulator Array for this location = -1
return result A
else if (CO2 Mass Equation Code == "F-2")
If (Current DHV Record Valid == true AND Calculated Diluent for C02 is not null AND FLOW Calculated Adjusted
Value is not null AND Calculated Moisture for C02 is not null)
CO 2 Calculated Adjusted Value = 0.00000057* Calculated Diluent for C02 * FLOW Calculated Adjusted
Value* [(100.0 - Calculated Moisture for C02) /100.0], ROUNDED to one decimal place.
else
Rpt Period C02 Mass Calculated Accumulator Array for this location = -1
return result A
else
Rpt Period C02 Mass Calculated Accumulator Array for this location = -1
return result A
else if (CO 2 App D Method Active for Hour == true)
if (CO2 App D Accumulator >= 0 AND Current Hourly Op Record.OperatingTime is between 0 and 1 (inclusive))
CO2 Calculated Adjusted Value = C02 App D Accumulator / Current Hourly Op Record.OperatingTime, rounded to one
decimal place.
else
if (Legacy Data Evaluation == false)
Environmental Protection Agency
Page 331 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Rpt Period C02 Mass Calculated Accumulator Array for this location = -1
return result A
else
Rpt Period C02 Mass Calculated Accumulator Array for this location = -2
else
CO2 Calculated Adjusted Value = Current DHV Calculated Adjusted Value
If (CO2 Calculated Adjusted Value is not null)
If {Current Hourly Op Record.Operat i ngTi me is between 0 and 1 inclusive)
C02 Total Calculated Value = CO2 Calculated Adjusted Value * Current Hourly Op Ttecon/.OperatingTime.
if (Rpt Period C02 Mass Calculated Accumulator Array for this location is not null)
if (Rpt Period C02 Mass Calculated Accumulator Array for this location >= 0)
Rpt Period C02 Mass Calculated Accumulator Array for this location = Rpt Period C02 Mass
Calculated Accumulator Array for this location + C02 Total Calculated Value
else
Rpt Period C02 Mass Calculated Accumulator Array for this location = C02 Total Calculated Value
else
Rpt Period C02 Mass Calculated Accumulator Array for this location = -1
If (Derived Hourly Adjusted Value Status == true)
C02 Tolerance = Lookup Tolerance from Cross-Check Table "Hourly Emissions Tolerances" where
Parameter = "C02" AND
UOM = "TNHR"
if (A B S(Current DH V Record. Adj ustcdHourly Va luc - CO2 Calculated Adjusted Value) > C02 Tolerance)
return result B
else
if (Rpt Period C02 Mass Calculated Accumulator Array for this location <> -2)
Rpt Period C02 Mass Calculated Accumulator Array for this location = -1
Results:
Result Response Severity
A The AdjustedHourly Value in the DHV record for [param] could not be recalculated due Informational Message
to errors listed above.
B The AdjustedHourly Value reported in the DHV record for [param] is inconsistent with Critical Error Level 1
the recalculated value.
Usage:
1 Process/Category: Emissions Data Evaluation Report C02 Mass Rate Calculation Verification
Environmental Protection Agency
Page 332 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURCV-25
Check Name:
Determine B AF Value for NOx Emission Rate System
Related Former Checks:
Applicability:
Description:
Specifications:
Current NOX System BAF = null
If (Current NOx System Status == true AND NOXR Calculated Unadjusted Value is not null AND Current NOx Rate Method Code in
set {CEM, PEM}) AND Current I)HVRecord.ModcCodc in set {01, 02, 03, 14, 22, 53})
If (RATA Status BAF is not null)
Current NOX System BAF = RA TA Status BAF
else
return result A
Results:
Result
A
Response
The BAF for [ParamCode] MonitoringSystemID [ID] cannot be determined, because
the prior RATA had critical errors or because of a RATA Status error listed on this
report.
Severity
Informational Message
Usage:
1 Process/Category: Emissions Data Evaluation Report NOX RATA Status Evaluation
Environmental Protection Agency
Page 333 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURCV-30
Check Name: Initialize S02 Calculated Hourly Data
Related Former Checks:
Applicability:
Description:
Specifications:
Current DHV Parameter = "S02"
Current DHVRecord Valid = SOI Derived Hourly Status
S02 Calculated Adjusted Value = null
Calculated Moisture for S02 = null
Current DHV Record = Current S02 Derived Hourly Record
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report S02 Calculation Verification
Environmental Protection Agency
Page 334 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURCV-31
Check Name:
Initialize NOX Calculated Hourly Data
Related Former Checks:
Applicability:
Description:
Specifications:
Current DHV Parameter = "NOX"
Current DHV Record Valid = NOX Derived Hourly Status
NOX Calculated Adjusted Value = null
Calculated Moisture for NOX = null
Current DHV Record = Current NOx Rate Derived Hourly Record
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report NOx Mass Rate Calculation Verification
Environmental Protection Agency
Page 335 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURCV-32
Check Name:
Initialize NOXR Calculated Hourly Data
Related Former Checks:
Applicability:
Description:
Specifications:
Current DHV Parameter = "NOXR"
Current DHVRecord Valid = NOXR Derived Hourly Status
NOXR Calculated Adjusted Value = null
Calculated Diluent for NOXR = null
Calculated Moisture for NOXR = null
Current DHVHBHA Value = Current NOXR HBHA Value
Current DHV Record = Current NOx Rate Derived Hourly Record
Current Appendix E Status = null
RATA Status Required = false
RA TA Status BAF = null
Current Hourly Record for RA TA Status = Current NOx Rate Derived Hourly Record
Set QaStatusComponentld = null
Set QaStatusComponentldentifier = null
Set QaStatusComponentTypeCode = null
Set QaStatusSystemDesignationCode = CurrentDHVRecord.S\s{cmr>cs'\gK\{\o\\CoAc
Set QaStatusSystemld = CurrentDHVRecord. Sy stcmId
Set QaStatusSystemldentifier = CurrentDH VRecord. Sy stem I dc nti fie r
Set QaStatusSystemTypeCode = CurrentDH VRecord.SyslcmTypcCodc
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report NOx Emissions Rate Calculation Verification
Environmental Protection Agency
Page 336 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURCV-33
Check Name: Initialize C02 Calculated Hourly Data
Related Former Checks:
Applicability:
Description:
Specifications:
Current DHV Parameter = "C02"
Current DHVRecord Valid = CO2 Derived Hourly Status
C02 Calculated Adjusted Value = null
Calculated Diluent for C02 = null
Calculated Moisture for C02 = null
Current DHV Record = Current C02 Mass Derived Hourly Record
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report C02 Mass Rate Calculation Verification
Environmental Protection Agency
Page 337 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURCV-34
Check Name:
Initialize C02C Calculated Hourly Data
Related Former Checks:
Applicability:
Description:
Specifications:
Current DHV Parameter = "C02C"
Current DHVRecord Valid = C02C Derived Hourly Status
C02C DHV Calculated Adjusted Value = null
Calculated Diluent for C02C = null
Calculated Moisture for C02C = null
Current DHVHBHA Value = Current C02C DHVHBHA Value
Current DHV Record = Current C02 Cone Derived Hourly Record
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report C02 Concentration Calculation Verification
Environmental Protection Agency
Page 338 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURCV-35
Check Name:
Initialize H20 Calculated Hourly Data
Related Former Checks:
Applicability:
Description:
Specifications:
Current DHV Parameter = "H20"
Current DHVRecord Valid = H20 Derived Hourly Status
H20 DHV Calculated Adjusted Value = null
Current DHVHBHA Value = Current H20 DHVHBHA Value
Current DHV Record = Current H20 Derived Hourly Record
Set QaStatusComponentld = null
Set QaStatusComponentldentifier = null
Set QaStatusComponentTypeCode = null
Set QaStatusSystemDesignationCode = CurrentDHVRecord.SystemDesigmtionCode
Set QaStatusSystemld = CurrentDHVRecord. Sy stcmId
Set QaStatusSystemldentifier = CurrentDHVRecord. Sy stem I dc nti fie r
Set QaStatusSystemTypeCode = CurrentDHVRecord. SystemTypeCode
if {CurrentDHVRecord.MODCCode in set {01, 02, 03, 21, 53} AND CurrentDHVRecord.SystemTypeCode == "H20")
RA TA Status Required = true
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report H20 Calculation Verification
Environmental Protection Agency
Page 339 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURCV-36
Check Name:
Initialize HI Calculated Hourly Data
Related Former Checks:
Applicability:
Description:
Specifications:
Current DHV Parameter = "HI"
Current DHV Record Valid = HI Derived Hourly Status
HI Calculated Adjusted Value = null
Calculated Diluent for HI = null
Calculated Moisture for HI = null
Current DHV Record = Current Heat Input Derived Hourly Record
RATA Status Required = false
Current Hourly Record for RA TA Status = Current Heat Input Derived Hourly Record
Set QaStatusComponentld = null
Set QaStatusComponentldentifier = null
Set QaStatusComponentTypeCode = null
Set QaStatusSystemDesignationCode = CurrentDHVRecord.SxsicmDcsigmiionCodc
Set QaStatusSystemldentifier = CurrentDHVRecord. Sy stem I dc nti fie r
Set QaStatusSystemTypeCode = CurrentDHVRecord.SxsicmTxpcCodc
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Heat Input Calculation Verification
Environmental Protection Agency
Page 340 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURCV-37
Check Name:
Check Unadjusted Value
Related Former Checks:
Applicability:
Description:
Specifications:
Derived Hourly Unadjusted Value Status = false
If (Current NOx Rate Method Code in set {CEM, PEM})
If (CurrentDHVRecord.ModcCode in set {01, 02, 03, 04, 14, 21, 22, 53, 54})
If (Current DHV Record. U nadj ustedHourly Value is not null)
If (Current DHV Record \) nadjustcdHourly Value < 0.0 AND
Current DHV Record. ModcCode <> "21")
return result A
Else if (Current DHV Record \] nadjustcdHourly Value > 0 AND
Current DHV Record. ModcCode == 21)
return result B
Else if (Current DHV Record X) nadjustcdHourly Value is not rounded to three decimal places)
return result F
Derived Hourly Unadjusted Value Status = true
if (Current DHV Max Min Value is not null AND (NOx Cone MODC is null OR is NOT in set {19,
20}))
if (Current DHV Record .{J litidjustedHourly Vtilue > Current DHV Max Min Value)
return result C
Else If (Current DHV Record. ModcCode not in set {04, 53, 54})
return result A
Else
Derived Hourly Unadjusted Value Status = true
Else if (Derived Hourly Mode Status == true)
If (Current DHV Record U nadj ustedHourly Value is not null)
return result D
Else
Derived Hourly Unadjusted Value Status = true
Else If (Current DH V Record. U nadj ustedHourly Val lie is not null)
return result E
Else
Derived Hourly Unadjusted Value Status = true
Else
Environmental Protection Agency
Page 341 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
A
B
C
D
E
F
Usage:
1
Response
The UnadjustedHourly Value reported in the DHV record for [param] is invalid. The
value must be greater than or equal to 0.
You reported anMODCCode of 21 in the DHV record for [param], but the
UnadjustedHourly Value is greater than 0.
Warning: The UnadjustedHourly Value reported in the DHV record for [param] is in
excess of the maximum value listed in the monitoring plan. Sources are required to
periodically (at least once annually) evaluate the appropriateness of these maximum
values in the monitoring plan and make proper adjustments when necessary.
Adjustments may include the need to update Span and/or Default values. You should
investigate the cause of these exceedances and determine whether adjustments to your
monitoring systems or monitoring plan are necessary.
You reported anMODCCode of [modcCode] in the DHV record for [param], so you
should not have reported a value for the UnadjustedHourly Value.
You reported an UnadjustedHourly Value in the DHV record for [param], A value in
this field should not be reported for the [param] [method] method.
You reported [fieldname] in the [type] record for [param] that is not rounded to the
appropriate precision for that parameter.
Severity
Critical Error Level 1
Critical Error Level 1
Informational Message
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Process/Category: Emissions Data Evaluation Report NOx Emissions Rate Calculation Verification
Environmental Protection Agency
Page 342 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURCV-38
Check Name: Determine Maximum or Minimum Value for Parameter in DHV Record
Related Former Checks:
Applicability:
Description:
Specifications:
Current DHV Max Min Value = null
If {Current DHV Record Valid == true AND
((Current DHV Parameter == "H20" AND H20 Method Code == "MWD") OR
(Current DHV Parameter == "NOXR" AND Current NOx Rate Method Code in set { CEM,PEM}) OR
Current DHV Parameter == "C02C" OR
Current DHV Parameter =="HI")
If (Current DHV Parameter == "H20")
If (H20 Fuel Specific Missing Data == true)
Current DHV Fuel Specific Hour = true
If (H20 Missing Data Approach == 'MAX")
Current DHVDefault Parameter = "H20X"
Else If (H20 Missing Data Approach == 'MIN")
Current DHV Default Par ameter = "H20N"
Else If (Current DHV Record. ModcCode== 12)
return result A
else if (Current DHV Parameter == "NOXR")
Current DHV Default Parameter = "NORX"
If (Current DHV Record. IVIodcCodc in set {23, 24})
If (NOx Rate Bypass Code== "BYMAXFS")
Current DHV Fuel Specific Hour = true
else
Current DHV Fuel Specific Hour = false
else if (NOx Rate Fuel Specific Missing Data == true)
Current DHV Fuel Specific Hour = true
else
Current DHV Fuel Specific Hour = false
else if (Current DHV Parameter == "C02C")
Current DHV Default Parameter = "C02X"
If (CO2 Fuel Specific Missing Data == true)
Current DHV Fuel Specific Hour = true
If (Current DHV Parameter == "HI")
Locate all active UnitCapacity records linked to the location where MaxHourlyHeatlnputCapacity > 0.
If any are found,
Set Current DHV Max Min Value to the sum of MaxHourlyHeatlnputCapacity in all records found,
else if (Current DHV Default Parameter is not null)
If (Current DHV Record. ModcCode in set {12, 23, 25} AND Current DHV Fuel Specific Hour = true)
If (Current Hourly Op Record.FuelCode is not null)
Environmental Protection Agency
Page 343 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Current DHVMissing Data Fuel = Current Hourly Op Record. FuclCodc
Count active MonitoringDefaultData record for location where
ParameterCode = Current DHV Default Parameter
FuelCode = Current Hourly Op Record.FuelCode
DefaultPurposeCode = "MD" // Missing Data
OperatingCode in set {A,U} // Not Controlled
if (count >1)
return result B
else if (count == 0)
return result C
else
Default Record = the single matched record
if (Defeat It Record. D c fa u 11V a 1 lie > 0)
Current DHV Max Min Value = Default Record. DefaultValue
else
return result D
else if {Current DHV Record. ModcCode in set {13, 24}
If (Current DHV Fuel Specific Hour == true)
If Current Hourly Op Record .FuelCode is not null
Current DHV Missing Data Fuel = Current Hourly Op Record. FuelCode
Count active MonitoringDefaultData record for location where
ParameterCode = Current DHV Default Parameter
FuelCode = Current Hourly Op Record.FuelCode
DefaultPurposeCode = 'MD" // Missing Data
OperatingCode in == "C" // Controlled
if (count >1)
return result B
else if (count == 0)
return result C
else
Default Record = the single matched record
if (Default Record. Default Value > 0)
Current DHV Max Min Value = Default Record .DefaultValue
else
return result D
else
Current DHV Missing Data Fuel = "NFS"
Count active MonitoringDefaultData record for location where
ParameterCode = Current DHV Default Parameter
FuelCode = "NFS"
DefaultPurposeCode = "MD" // Missing Data
OperatingCode in == "C" // Controlled
if (count >1)
return result B
else if (count == 0)
Environmental Protection Agency
Page 344 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
return result C
else
Default Record = the single matched record
if (Defeat It Record. D c fa u 11V a 1 lie > 0)
Current DHVMax Min Value = DefaultRecorJ.DefaultValue
else
return result D
else if {Current DHV Record. ModcCode <> "15"
Current DHV Missing Data Fuel = "NFS"
Count active MonitoringDefaultData record for location where
ParameterCode = Current DHV Default Parameter
FuelCode = "NFS"
DefaultPurposeCode = "MD" // Missing Data
OperatingCode in set {A,U} // Not Controlled
if (count >1)
return result B
else if {count == 0 AND Current DHV Parameter == "C02C")
Monitor Span Record Count = Find active MonitoringSpanData records for location where
MonitoringSpanData .ComponentTypeCode = "C02" AND
MonitoringSpanData. SpanScaleCode = "H"
if {Monitor Span Record Count > 1)
return result E
else if {Monitor Span Record Count = 0)
return result F
else
Current Monitor Span Record = the single matched record
If {Current Monitor Span Record. DefaultHighRange is null AND Current DHV
Record.ModcCode not in set {13, 24})
if {CurrentMonitor Span Record.MPCValue > 0)
Current DHV Max Min Value = Current Monitor Span Record.MPCValus
else
return result G
else if {count == 0 AND Current DHV Parameter == "NOXR")
Count active MonitoringDefaultData record for location where
ParameterCode = "MNNX"
FuelCode = "NFS"
DefaultPurposeCode = "MD" // Missing Data
OperatingCode in set {A,U} // Not Controlled
if {count >1)
Current DHV Default Parameter = 'MNNX"
return result B
else if {count = 0)
return result C
Environmental Protection Agency
Page 345 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
else
Current DHVDefault Parameter = 'MNNX"
Default Record = the single matched record
if (Defeat It Record. D c fan 11V a 1 lie >= 0)
Current DHV Max Min Value = Default Recor J.DefaultValue
else
return result D
else if (count == 0)
return result C
Default Record = the single matched record
if (Defeat It Record. D c fa u 11V a 1 lie > 0)
Current DHV Max Min Value = Default Record. Default Value
else
return result D
Results:
Result Response Severity
A The missing data default parameter for H20 could not be determined, because you used Critical Error Level 2
both Standard and Inverse Part 75 missing data approaches during the hour.
B You reported more than one applicable [param] Default record with a FuelCode of Critical Error Level 1
[FuelCode] in your monitoring plan for the hour.
C You did not report an applicable [param] Default record with a FuelCode of Critical Error Level 1
[FuelCode].
D The values reported in the applicable [param] Default record with a FuelCode of Critical Error Level 1
[FuelCode] are invalid.
E You reported more than one active span record for [key] in your monitoring plan for the Critical Error Level 1
hour.
F You did not report a missing data maximum default for C02 in a span or default record Critical Error Level 1
in your monitoring plan.
G The values reported in the applicable span record for [key] are invalid. Critical Error Level 1
Usage:
1
Process/Category:
Emissions Data Evaluation Report —
— C02 Concentration Calculation Verification
2
Process/Category:
Emissions Data Evaluation Report —
— H20 Calculation Verification
3
Process/Category:
Emissions Data Evaluation Report —
— Heat Input Calculation Verification
4
Process/Category:
Emissions Data Evaluation Report —
— NOx Emissions Rate Calculation Verification
Environmental Protection Agency
Page 346 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURCV-39
Check Name: Check Adjusted Hourly Value in DHV Record
Related Former Checks:
Applicability:
Description:
Validation Tables:
Parameter UOM (Complex Lookup Table)
Specifications:
Derived Hourly Adjusted Value Status = false
Current DHV Calculated Adjusted Value = null
if {Current DHV Record Valid == true)
Locate Parameter Units of Measure lookup table record where ParameterCode = Current DHV Parameter.
If (Hourly Fuel Flow Count For Gas is greater than 0 AND Current DHV Parameter == "S02")
Set Current DHV Precision to 4.
else
Set Current DHV Precision to the Parameter Units of Measure.r>cc\\K\\s_Hr\\.
if (Current DHV Record.ModcCode is not null)
case (Current DHV Record. ModcCodc )
= 21: Current DHV Calculated Adjusted Value = 0
if (Current DHV Record. Ad) ustedHourly Value == 0)
Derived Hourly Adjusted Value Status = true
else
return result A
= 12 OR 23 OR 25:
If (Current DHV Max Min Value is not null)
Current DHV Calculated Adjusted Value = Current DHV Max Min Value
if (Current DHV Record. Adj ustedHourlyValue == Current DH V Max Min Value)
Derived Hourly Adjusted Value Status = true
else
return result B
= 13 OR 24:
If (Current DHV Max Min Value is not null)
Current DHV Calculated Adjusted Value = Current DHV Max Min Value
if (Current DHV Record. Adj ustedHourlyValue == Current DH V Max Min Value)
Derived Hourly Adjusted Value Status = true
else
return result C
= 06:
If (Current DHV Parameter in set {C02C, H20} AND (Current DHV Record. Ad) ustedHourly Value is null or
Current DHV /fecwf/. Adj ustedHourly Value < 0 or Current DHV Record. Adj ustedHourlyValue > 100))
return result L
else if (Current DHVHBHA Value is not null)
Environmental Protection Agency
Page 347 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Current DHV Calculated Adjusted Value = Current DHVHBHA Value
If (Current /)//K/?6'cmy/. Adj ustedHourly Value >= 0)
if ( Current DHV /?£6y>/y/. AdjiistcdHourly Value == Current DHV Calculated Adjusted Value)
Derived Hourly Adjusted Value Status = true
else
return result D
else
return result E
else
If (Current /)//K/?6'cmy/. Adj ustedHourly Value >= 0)
If (Current DHV Record. Ad) ustedHourly Value is not rounded to Current DHV Precision)
return result M
else
Current DHV Calculated Adjusted Value = Current DHV Record. Ad) ustedHourly Value
Derived Hourly Adjusted Value Status = true
if {Current DHV Parameter in set {C02C, H20, NOXR} AND Current DHV Max Min
Value is not null)
If {Current DHV Parameter == "H20" AND H2() Missing Data Approach ==
"MIN")
if (Current /)//K/?6'cwY/.Adj ustedHourly Value < Current DHV Max
Min Value)
return result H
else
if (Current DHV Record. Adj ustedHourly Value > Current DHV Max
Min Value)
If {Current DHV Parameter == "NOXR" and Current DHV
Record. Adj ustedHourly Value > Current DHV Max Min Value
*2)
return result O
Otherwise,
return result G
Else
return result E
= 08 OR 09:
If {Current DHV Parameter in set {C02C, H20} AND (Current /)//K/?6'cwy/. Adj ustedHourly Value is null or
Current DHV/fecwf/. Adj ustedHourly Value < 0 or Current DHV/?6'cwY/.AdjustedHourly Value > 100))
return result L
else if (Current DHV/?£6Y>/Y/.AdjustcdHourly Value >= 0)
If {Current DHV HBHA Value is not null AND Current DHV Parameter == "H20" AND H20 Missing
Data Approach == 'MIN" AND Current DHV HBHA Value < Current DHV
Record. Adj ustedHourly Value)
Current DHV Calculated Adjusted Value = Current DHV HBHA Value
return result N
else if {Current DHV HBHA Value is not null AND {Current DHV Parameter <> "H20" OR H20
Missing Data Approach == "MAX") AND Current DHV HBHA Value > Current DHV
Record. Ad) ustedHourly Value AND {Unit is Load Based == true or Current DHV Parameter <>
"NOXR"))
Current DHV Calculated Adjusted Value = Current DHV HBHA Value
return result F
Environmental Protection Agency
Page 348 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
elseif {Current DHV Record.hdi)us\c.dHo\ix\\Vc\\\ic. is not rounded to Current DHVPrecision)
return result M
else
Current DHV Calculated Adjusted Value = Current Adj ustedHourly Value
Derived Hourly Adjusted Value Status = true
if {Current DHV Parameter in set {C02C, H20, NOXR} AND Current DHV Max Min Value
is not null)
If {Current DHV Parameter == "H20" AND H2() Missing Data Approach == "MIN")
if (Current DHV Record. Adi) ustedHourly Value < Current DHV Max Min
Value)
return result H
else
if (Current DHV Record. Adi) ustedHourly Value > Current DHV Max Min
Value)
If {Current DHV Parameter == "NOXR" and Current DHV
Record. A dj us tcdH o u rly V a 1 lie > Current DHV Max Min Value * 2)
return result O
Otherwise,
return result G
Else
return result E
= 04, 05, 07, 10, 11, 15, 53, 54, OR 55:
If {Current DHV Parameter in set {C02C, H20} AND (Current DHV Record. Ad) ustedHourly Value is null or
Current DHV Record. Ad)ustedRourlyYalue < 0 or Current DHV Record. Ad)ustedRourlyYalue > 100))
return result L
elseif (Current DHV Record. Ad) ustedHourly Value >= 0)
If {Current DHV Record. Adj ustedHourly Value is not rounded to Current DHV Precision)
return result M
else
Current DHV Calculated Adjusted Value = Current DHV Record. Adi)u?XcdY{oux\\Yi\\uc
Derived Hourly Adjusted Value Status = true
if {Current DHV Parameter in set {C02C, H20, NOXR} AND Current DHV Max Min Value
is not null)
If {Current DHV Parameter == "H20" AND H2() Missing Data Approach == "MIN")
if (Current DHV Record. Adi) ustedHourly Value < Current DHV Max Min
Value)
return result H
else
if (Current DHV Record. Ad) ustedHourly Value > Current DHV Max Min
Value)
If {Current DHV Parameter == "NOXR" and Current DHV
Record. Adj ustedHourly V al lie > Current DHV Max Min Value * 2)
return result O
Otherwise,
return result G
Else
return result E
= 26: If (Current DHV Record. Ad) ustedHourly Value == 1)
Derived Hourly Adjusted Value Status = true
else
Environmental Protection Agency
Page 349 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
return result I
= All Other Codes except 40:
If {CurrentDHVParameter in set {C02C, H20} AND (Current DHV Record .k&\us{cAHo\.tf\\V'c\\\iC is null or
Current DHV/fecwY/.AdjustcdHourly Value < 0 or Current DHV/?6'cwY/.AdjustedHourly Value > 100))
return result L
else if (Current DHV Record. A dj us tcdH o u rly V a 1 lie >= 0)
If {Current DHV Record. AdjustedHourly Value is not rounded to Current DHV Precision)
return result M
else
Derived Hourly Adjusted Value Status = true
If {Current DHV Parameter in set {C02C, H20} AND Current DHV Max Min Value is not
null)
If {Current DHV Parameter == "H20" AND H2() Missing Data Approach == "MIN")
if {Current DHV Record. AdjustedHourlyValue < Current DHV Max Min
Value)
return result H
else
if {Current DHV Record. AdjustedHourlyValue > Current DHV Max Min
Value)
return result G
Else
return result E
else
If {Current DHV Record. AdjustedHourlyValue >= 0)
If {Current DHV Record. AdjustedHourlyValue is not rounded to Current DHV Precision)
return result M
else
Derived Hourly Adjusted Value Status = true
If {Current DHV Parameter == "HI")
if {Heat Input Method Code not in set {AD, ADCALC, CALC})
Current DHV Calculated Adjusted Value = Current DHV Record. AdjustedHourlyValue
If (Current DHV Record. Ad) ustcdH ourly Value == 0.0)
If {Heat Input Method Code== "CEM")
If Legacy Data Evaluation = true
If {Current Hourly Op Record.OpTime > 0.25)
return result J
else
If {Current Hourly Op Record. OpTime > 0)
return result K
else if {Current DHV Max Min Value is not null and Current DHV
Record AA) ustcdH ourly Value > Current DHV Max Min Value)
return result G
else if {Current DHV Parameter == "NOXR")
if {Current NOx Rate Method Code<> "AE")
Environmental Protection Agency
Page 350 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
else
Current DHV Calculated Adjusted Value = Current DHV Record. Ad) ustedHourly Value
else if {Current DHV Parameter == "S02")
if (S02 App D Method Active for Hour == false)
Current DHV Calculated Adjusted Value = Current DHV Record. Ad) ustedHourly Value
else if {Current DHV Parameter == "C02")
if (CO 2 App D Method Active for Hour == false)
Current DHV Calculated Adjusted Value = Current DHV Record. Ad) ustedHourly Value
else
Current DHV Calculated Adjusted Value = Current DHV Record. AdjustedHourlyValue
return result E
Environmental Protection Agency
Page 351 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
A
B
C
D
E
F
H
I
J
K
L
M
N
O
Response
You reported an MOD CCode of 21 in the DH V record for [param], but the
AdjustedHourly Value does not equal 0.
You reported an MOD CCode of [modcCode] in the DHV record for [param], but the
AdjustedHourly Value does not equal the maximum potential value reported in the span
or default record in your monitoring plan.
You reported an MOD CCode of 13 or 24 in the DHV record for NOXR, but the
AdjustedHourly Value does not equal the maximum controlled emission rate reported in
the NORX default record in your monitoring plan.
You reported an MOD CCode of 06 in the DHV record for [param], but the
AdjustedHourly Value does not equal average of measured hour before and measured
hour after.
The AdjustedHourly Value reported in the DHV record for [param] is invalid. The
value must be greater than or equal to 0.
You reported an MODCCode of [MODCCode] in the DHV record for [param], but you
reported an AdjustedHourly Value that is less than the average of the measured hour
before and measured hour after.
Warning: The AdjustedHourly Value reported in the DHV record for [param] is in
excess of the maximum value listed in the monitoring plan. Sources are required to
periodically (at least once annually) evaluate the appropriateness of these maximum
values in the monitoring plan and make proper adjustments when necessary.
Adjustments may include the need to update Span, Default, and/or Unit Capacity
values. You should investigate the cause of these exceedances and determine whether
adjustments to your monitoring systems or monitoring plan are necessary.
Warning: The AdjustedHourly Value reported in the DHV record for [param] is lower
than the minimum value listed in the monitoring plan. Sources are required to
periodically (at least once annually) evaluate the appropriateness of these minimum
values in the monitoring plan and make proper adjustments when necessary.
Adjustments may include the need to update Span Default values. You should
investigate the cause of these low values and determine whether adjustments to your
monitoring systems or monitoring plan are necessary.
You reported an MODCCode of 26 in the DHV record for [param], but the
AdjustedHourly Value does not equal 1.
You reported an AdjustedHourly Value of 0 in the DHV record for HI, but you operated
more than 0.25 hour.
You reported an AdjustedHourly Value of 0 in the DHV record for HI, but you had
operating time during the hour. If you operated, you must report a heat input rate of at
least 1 mmBtu/hr.
The AdjustedHourly Value reported in the DHV record for [param] is invalid. The
value must be between 0 and 100.
You reported [fieldname] in the [type] record for [param] that is not rounded to the
appropriate precision for that parameter.
You reported an MODCCode of [MODCCode] in the DHV record for [param], but you
reported an AdjustedHourly Value that is greater than the average of the measured hour
before and measured hour after.
The AdjustedHourly Value reported in the DHV record for NOXR is in excess of 200%
of the maximum value listed in the monitoring plan. Sources are required to
periodically (at least once annually) evaluate the appropriateness of these maximum
values in the monitoring plan and make proper adjustments when necessary.
Adjustments may include the need to update Span and/or Default values. You should
investigate the cause of these exceedances and determine whether adjustments to your
monitoring systems or monitoring plan are necessary.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Informational Message
Informational Message
Critical Error Level 1
Non-Critical Error
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 2
Environmental Protection Agency
Page 3 52 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Usage:
1
Process/Category:
Emissions Data Evaluation Report —
— C02 Concentration Calculation Verification
2
Process/Category:
Emissions Data Evaluation Report —
— C02 Mass Rate Calculation Verification
3
Process/Category:
Emissions Data Evaluation Report —
— H20 Calculation Verification
4
Process/Category:
Emissions Data Evaluation Report —
— Heat Input Calculation Verification
5
Process/Category:
Emissions Data Evaluation Report —
— NOx Emissions Rate Calculation Verification
6
Process/Category:
Emissions Data Evaluation Report —
— NOx Mass Rate Calculation Verification
7
Process/Category:
Emissions Data Evaluation Report —
— S02 Calculation Verification
Environmental Protection Agency
Page 353 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURCV-40
Check Name:
Determine Moisture for S02 Mass Calculation Verification
Related Former Checks:
Applicability:
Description:
Specifications:
If (S()2 Method Code begins with "CEM")
if (S02 Mass Equation Code== "F-2")
ff (H20 Method Code == "MWD" AND H20 Derived Hourly Checks Needed == true AND H2() DHV Calculated
Adjusted Value is not null)
Calculated Moisture for S02 = H20 DHV Calculated Adjusted Value
else if (H20 Method Code in set {MMS, MTB } AND H20 Monitor Hourly Checks Needed == true AND H20MHV
Calculated Adjusted Value is not null)
Calculated Moisture for S02 = H20 MHV Calculated Adjusted Value
else if (H20 Method Code == "MDF" AND H20 Derived Hourly Checks Needed == true AND H20 DHV Calculated
Adjusted Value is not null)
Calculated Moisture for S02 = H20 DHV Calculated Adjusted Value
else if (H20 Method Code == 'MDF" AND H20 Derived Hourly Checks Needed == false AND H20 Default Value is
not null)
Calculated Moisture for S02 = H20 Default Value
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report S02 Calculation Verification
Environmental Protection Agency
Page 354 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURCV-41
Check Name: Calculate Adjusted NOx Rate in DHV Record
Related Former Checks:
Applicability:
Description:
Validation Tables:
Hourly Emissions Tolerances (Cross Check Table)
Specifications:
if (Derived Hourly Adjusted Value Status == true)
if (Rpt Period NOx Rate Reported Accumulator Array for this location is not null)
if (Rpt Period NOx Rate Reported Accumulator Array for this location >= 0)
Rpt Period NOx Rate Reported Accumulator Array for this location = Rpt Period NOx Rate Reported
Accumulator Array fortius location + Current DHV Record. AdjustedHourly Value
else
Rpt Period NOx Rate Reported Accumulator Array fortius location= Current DHV Record. AdjustedHourly Value
else
Rpt Period NOx Rate Reported Accumulator Array for this location = -1
if (RATA Status Required == true AND Current NOX System BAF is not null)
NOXR Calculated Adjusted Value = NOXR Calculated Unadjusted Value * Current NOX System BAF, and round the result to
three decimal places
else if (Current NOx Rate Method Code == "AE" AND Hourly Fuel Flow Count for Gas + Hourly Fuel Flow Count for Oil > 0 AND
App E Constant Fuel Mix == false)
If (NOXR App E Accumulator >= 0 AND HI Calculated Adjusted Value is not null AND Current Hourly Op
Record.OperatingTime is between 0 and 1 (inclusive))
If (NOXR App E Accumulator == 0)
NOXR Calculated Adjusted Value = 0
else
NOXR Calculated Adjusted Value = NOXR App E Accumulator / Total Heat Input from Fuel Flow, and round
the result to three decimal places
else
Apportionment Calc NOXR Array at this Location = -1
Rpt Period NOx Rate Calculated Accumulator Array for this location = -1
return result A
If (NOXR Calculated Adjusted Value is not null)
Apportionment Calc NOXR Array at this Location = NOXR Calculated Adjusted Value
if (MP Stack Config for Hourly Checks == "MS" AND Expected Summary Value NOx Rate Array for the location == true)
if (Config NOxRateTimesHeatlnput Accumulator >= 0 AND HI Calculated Adjusted Value is not null)
Config NOxRateTimesHeatlnput Accumulator = Config NOxRateTimesHeatlnput Accumulator + (HI
Calculated Adjusted Value * NOXR Calculated Adjusted Value)
else
Config NOxRateTimesHeatlnput Accumulator = -1
if (Config NOxRateTimesOpTime Accumulator >= 0 AND Current Hourly Op Record.Operati ngTime is between 0 and
1 (inclusive))
Config NOxRateTimesOpTime Accumulator = Config NOxRateTimesOpTime Accumulator + (Current Hourly
Op Record .Opc rat i ngT i me * NOXR Calculated Adjusted Value)
Config OpTime Accumulator = Config Op Time Accumulator + Current Hourly Op Record. OperatingTime
else
Environmental Protection Agency
Page 355 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Config NOxRateTimesOpTime Accumulator = -1
Rpt Period NOx Rate Hours Accumulator Array for this location = Rpt Period NOx Rate Hours Accumulator Array for this
location + 1
if (Derived Hourly Adjusted Value Status == true AND Derived Hourly Unadjusted Calculation Status == true)
Tolerance = Lookup Tolerance from Cross-Check Table "Hourly Emissions Tolerances" where
Parameter = "NOXR" AND
UOM = "LBMMBTU"
if ABS(NOXR Calculated Adjusted Value - Current DHV Record. Ad) ustedHourly Value) > Tolerance
return result B
else if Current NOx Rate Method Code <> " AE" OR Hourly Fuel Flow Count for Gas + Hourly Fuel Flow Count for Oil > 0)
>0)
Apportionment Calc NOXR Array at this Location = -1
Rpt Period NOx Rate Calculated Accumulator Array for this location = -1
if (MP Stack Config for Hourly Checks == "MS")
Config NOxRateTimesHeatlnput Accumulator = -1
if (RA TA Status Required == true AND Current NOX System BAF is null AND NOXR Calculated Unadjusted Value is not null
)
return result A
Results:
Result
A
Response
The AdjustedHourly Value in the DHV record for [param] could not be recalculated due
to errors listed above.
The AdjustedHourly Value reported in the DHV record for [param] is inconsistent with
the recalculated value.
Severity
Informational Message
B
Critical Error Level 1
Environmental Protection Agency
Page 356 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
Usage:
1 Process/Category: Emissions Data Evaluation Report NOx Emissions Rate Calculation Verification
Conditions: RATA Status Required Equals false
2 Process/Category: Emissions Data Evaluation Report NOX RATA Status Evaluation
Environmental Protection Agency
Page 3 57 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURCV-42
Check Name:
Related Former Checks:
Check HI System in DHV Record
Applicability:
Description:
Specifications:
If Current DHV Parameter == "HI" AND Heat Input Method Code in set {CEM, AMS})
If (Current DHV Record. Mo nito ri ngSy stc m ID is null
If {Heat Input Method Code == "CEM" AND
(CO2 Cone Checks Needed for Heat Input == true AND Current C02 Cone Monitor Hourly Record is
not null AND Current C02 Cone Monitor Hourly Record. ModcCode in set {01, 02, 03, 04, 17, 20, 21})
OR
(()2 Wet Checks Needed for Heat Input == true AND Current 02 Wet Monitor Hourly Record is not
null AND Current 02 Wet Monitor Hourly Record.ModcCode in set {01, 02, 03, 04, 17, 20}) OR
(02 Dry Checks Needed for Heat Input == true AND Current 02 Dry Monitor Hourly Record is not
null AND Current 02 Dry Monitor Hourly Record.ModcCode in set {01, 02, 03, 04, 17, 20}))
If {Heat Input Method Code == "CEM" AND
((C02 Cone Checks Needed for Heat Input == false OR (Current C02 Cone Monitor Hourly Record is
not null AND Current C02 Cone Monitor Hourly Record.ModcCode NOT in set {01, 02, 03, 04, 05, 17,
20,21,53, 54})) AND
(()2 Wet Checks Needed for Heat Input == false OR {Current 02 Wet Monitor Hourly Record is not
null AND Current 02 Wet Monitor Hourly Record.ModcCode NOT in set {01, 02, 03, 04, 05, 17, 20,
53, 54})) AND
(()2 Dry Checks Needed for Heat Input == false OR {Current 02 Dry Monitor Hourly Record is not null
AND Current 02 Dry Monitor Hourly Record.ModcCode NOT in set {01, 02, 03, 04, 05, 17, 20, 53,
54})))
If {Current DHV Record Valid == true)
return result B
else
HI DHVMon Sys Record = find active MonitoringSy stemData record for location where
MonitoringSystemData.MonitoringSystemID = Current DHV /?6'ewY/.Monitori ngSystcmID
if {HI DHV Mon Sys Record is null)
return result C
else if {HI DHV Mon Sys Record. SystemTypeCode not in set {C02, 02})
return result D
else
if (CO2 RATA Required == true)
RA TA Status Required = true
return result A
else
Environmental Protection Agency
Page 358 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
A
B
C
D
Usage:
1
Response
You did not report MonitoringSystemID in the DHV record for HI. While this was
acceptable for legacy data, this field is required when you report measured data.
You reported a MonitoringSystemID in the DHV record for [param]. This field should
be blank when missing data substitution is used.
You reported MonitoringSystemID [ID] in the DHV record for [param], but according
to your monitoring plan this system was not active during the hour.
You reported MonitoringSystemID [ID] in the DHV record for HI, but this system is
not a C02 or 02 monitoring system.
Severity
Critical Error Level 1
Non-Critical Error
Critical Error Level 1
Critical Error Level 1
Process/Category: Emissions Data Evaluation Report Heat Input Calculation Verification
Environmental Protection Agency
Page 359 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURCV-43
Check Name: Determine DHV Measure Code
Related Former Checks:
Applicability:
Description:
Specifications:
Set Current Measure Code to null.
If (Current DHV Parameter in set {C02C, H20})
If (Current DHV Record. ModcCode in set {01, 02, 03, 04, 21, 53, 54})
Set Monitor Measure Code Array for the Current DHV Parameter to "MEASURE"
if (Current DHV Parameter == "C02C" AND CO 2 Cone CEM Equation Code == "F-14B" AND Monitor Measure
Code Array for "H20" == "SUB")
Set Monitor Measure Code Array for "C02C" to "MEASSUB".
else if (Current DHV Record. ModcCode in set {06, 07, 08, 09, 10, 12, 55})
Set Monitor Measure Code Array for the Current DHV Parameter to "SUB"
if (Current DHV Parameter == "C02C" AND CO 2 Cone CEM Equation Code== "F-14B" AND Monitor Measure
Code Array for "H20" == "MEASURE")
Set Monitor Measure Code Array for "C02C" to "MEASSUB".
else if (Current DHV Parameter == "NOXR")
If (Current NOx Rate Method Code in set {CEM, PEM}
ff (Current DHV Record. ModcCode in set {01, 02, 03, 04, 05, 14, 21, 22, 53, 54})
Set Current Measure Code" to "MEASURE".
if (NOx Rate Equation Code in set {19-3, 19-3D, 19-4, 19-5, 19-8, 19-9} ANT) Monitor Measure Code Array
for "H20" == "SUB")
set Current Measure Code to "MEASSUB".
else if (Current DHV Record. ModcCode in set {06, 07, 08, 09, 10, 11, 12, 13, 15, 23, 24, 25, 55})
Set Current Measure Code to "SUB"
if (NOx Rate Equation Code in set {19-3, 19-3D, 19-4, 19-5, 19-8, 19-9} ANT) Monitor Measure Code Array
for "H20" == 'MEASURE")
set Current Measure Code to "MEASSUB".
else if (Current NOx Rate Method Code == "AE")
Set Current Measure Code to the Monitor Measure Code Array for "NOXR".
Set NOXR Measure Code to the Current Measure Code.
else if (Current DHV Parameter == "HI")
If (Heat Input Method Code == "CEM")
if (Heat Input Equation Code in set {F-15, F-16})
If (Monitor Measure Code Array for "C02C" and "FLOW" are both equal to "MEASURE")
set Current Measure Code to "MEASURE".
Environmental Protection Agency
Page 360 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
else if (Monitor Measure Code Array for "C02C" and "FLOW" are both equal to "SUB")
set Current Measure Code to "SUB".
else if (Monitor Measure Code Array for "C02C" and "FLOW" are both not null)
set Current Measure Code to "MEASSUB".
else if {Heat Input Equation Code in set {F-18})
If (Monitor Measure Code Array for "02D" and "FLOW" are both equal to "MEASURE")
set Current Measure Code to "MEASURE".
else if (Monitor Measure Code Array for "02D" and "FLOW" are both equal to "SUB")
set Current Measure Code to "SUB".
else if (Monitor Measure Code Array for "02D" and "FLOW" are both not null)
set Current Measure Code to "MEASSUB".
else if (Heat Input Equation Code in set {F-17})
If (Monitor Measure Code Array for "02W" and "FLOW" are both equal to "MEASURE")
set Current Measure Code to "MEASURE".
else if (Monitor Measure Code Array for "02 W" and "FLOW" are both equal to "SUB")
set Current Measure Code to "SUB".
else if (Monitor Measure Code Array for "02 W" and "FLOW" are both not null)
set Current Measure Code to "MEASSUB".
if (Heat Input Equation Code in set {F-16, F-17, F-18} AND Monitor Measure Code Array for "H20" is not null)
If ((Current Measure Code == 'MEASURE" AND Monitor Measure Code Array for "H20" == "SUB") OR
(Current Measure Code == "SUB" AND Monitor Measure Code Array for "H20" == "MEASURE"))
set Current Measure Code to "MEASSUB".
else if (Heat Input App D Method Active for Hour == true)
If (Monitor Measure Code Array for "FF" in set {OTHER, MEASSUB})
set Current Measure Code to Monitor Measure Code Array for "FF".
else if (Monitor Measure Code Array for "FF" and "GCV" are both equal to "MEASURE")
set Current Measure Code to "MEASURE".
else if (Monitor Measure Code Array for "FF" and "GCV" are both equal to "SUB")
set Current Measure Code to "SUB".
else if (Monitor Measure Code Array for "FF" and "GCV" are both not null)
set Current Measure Code to "MEASSUB".
if (Monitor Measure Code Array for "DENSITY" is not null)
If ((Current Measure Code == 'MEASURE" AND Monitor Measure Code Array for "DENSITY" == "SUB")
OR (Current Measure Code == "SUB" AND Monitor Measure Code Array for "DENSITY" == "MEASURE"))
set Current Measure Code to "MEASSUB".
Set HI Measure Code to the Current Measure Code.
else if (Current DHVParameter == "S02")
Environmental Protection Agency
Page 361 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
If (S02 CEM Method Active for Hour == true)
If (Monitor Measure Code Array for "S02C" and "FLOW" are both equal to "MEASURE")
set Current Measure Code to "MEASURE".
else if (Monitor Measure Code Array for "S02C" and "FLOW" are both equal to "SUB")
set Current Measure Code to "SUB".
else if (Monitor Measure Code Array for "S02C" and "FLOW" are both not null)
set Current Measure Code to "MEASSUB".
if (SO2 Equation Code == "F-2" AND Monitor Measure Code Array for "H20" is not null)
If ((Current Measure Code == "MEASURE" AND Monitor Measure Code Array for "H20" == "SUB") OR
(Current Measure Code == "SUB" AND Monitor Measure Code Array for "H20" == 'MEASURE"))
set Current Measure Code to "MEASSUB".
else if (SO 2 F23 Method Active for Hour == true)
set Current Measure Code to HI Measure Code.
else if (SO 2 App D Method Active for Hour == true)
If (Monitor Measure Code Array for "FF" in set {OTHER, MEASSUB} OR Monitor Measure Code Array for
"SULFUR" is null)
set Current Measure Code to Monitor Measure Code Array for "FF".
else if (Monitor Measure Code Array for "FF" and "SULFUR" are both equal to "MEASURE")
set Current Measure Code to "MEASURE".
else if (Monitor Measure Code Array for "FF" and "SULFUR" are both equal to "SUB")
set Current Measure Code to "SUB".
else if (Monitor Measure Code Array for "FF" is not null)
set Current Measure Code to "MEASSUB".
else if (CurrentDHVParameter == "C02")
If (C02 Method Code == "CEM")
If (Monitor Measure Code Array for "C02C" and "FLOW" are both equal to "MEASURE")
set Current Measure Code to "MEASURE".
else if (Monitor Measure Code Array for "C02C" and "FLOW" are both equal to "SUB")
set Current Measure Code to "SUB".
else if (Monitor Measure Code Array for "C02C" and "FLOW" are both not null)
set Current Measure Code to "MEASSUB".
if (CO2 Mass Equation Code == "F-2" AND Monitor Measure Code Array for "H20" is not null)
If ((Current Measure Code == 'MEASURE" AND Monitor Measure Code Array for "H20" == "SUB") OR
(Current Measure Code == "SUB" AND Monitor Measure Code Array for "H20" == 'MEASURE"))
set Current Measure Code to "MEASSUB".
else if (CO2 App D Method Active for Hour == true)
Environmental Protection Agency
Page 362 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
set Current Measure Code to HI Measure Code.
else if {Current DHVParameter == "NOX")
if (NOx Mass Equation Code== "F-24A")
If (HI Measure Code and NOXR Measure Code are both equal to "MEASURE")
set Current Measure Code to "MEASURE".
else if (HI Measure Code and NOXR Measure Code are both equal to "SUB")
set Current Measure Code to "SUB".
else if (HI Measure Code and NOXR Measure Code are both not null)
set Current Measure Code to "MEASSUB".
else if (NOx Mass Equation Code in set {F-26A, F-26B })
ff (Monitor Measure Code Array for "NOXC" and "FLOW" are both equal to "MEASURE")
set Current Measure Code to "MEASURE".
else if (Monitor Measure Code Array for "NOXC" and "FLOW" are both equal to "SUB")
set Current Measure Code to "SUB".
else if (Monitor Measure Code Array for "NOXC" and "FLOW" are both not null)
set Current Measure Code to "MEASSUB".
if (NOx Mass Equation Code== "F-26B" AND Monitor Measure Code Array for "H20" is not null)
If ({Current Measure Code == 'MEASURE" AND Monitor Measure Code Array for "H20" == "SUB") OR
(Current Measure Code == "SUB" AND Monitor Measure Code Array for "H20" == "MEASURE"))
set Current Measure Code to "MEASSUB".
else if (Current DHV Parameter in set {S02M, NOXM, C02M, HIT}
Set Current Measure Code to "LME".
Results:
Result
Response
Severity
Environmental Protection Agency
Page 363 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Usage:
1
Process/Category
2
Process/Category
3
Process/Category
4
Process/Category
5
Process/Category
6
Process/Category
7
Process/Category
8
Process/Category
9
Process/Category
10
Process/Category
11
Process/Category
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
C02 Concentration Calculation Verification
C02 Mass Rate Calculation Verification
C02M Derived Hourly Evaluation (LME)
H20 Calculation Verification
Heat Input Calculation Verification
HIT Derived Hourly Evaluation (LME)
NOx Emissions Rate Calculation Verification
NOx Mass Rate Calculation Verification
NOXM Derived Hourly Evaluation (LME)
S02 Calculation Verification
S02M Derived Hourly Evaluation (LME)
Environmental Protection Agency
Page 364 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Category:
Hourly Derived Data
Environmental Protection Agency
Page 365 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURDHV-1
Check Name: Initialize S02 Derived Hourly Data
Related Former Checks:
Applicability:
Description:
Specifications:
Current DHV Parameter = "S02"
SO2 Derived Hourly Status = true
Current DHV Record = Current S02 Derived Hourly Record
Current DHV Method = S02 Method Code
Current DHV System Type = null
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report S02 Derived Hourly Evaluation
Environmental Protection Agency
Page 366 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURDHV-2
Check Name: Initialize NOX Derived Hourly Data
Related Former Checks:
Applicability:
Description:
Specifications:
Current DHV Parameter = "NOX"
NOX Derived Hourly Status = true
Current DHV Record = Current NOx Mass Derived Hourly Record
Current DHV Method = NOx Mass Monitor Method Code
Current DHV System Type = null
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report NOx Mass Rate Derived Hourly Evaluation
Environmental Protection Agency
Page 367 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURDHV-3
Check Name:
Initialize NOXR Derived Hourly Data
Related Former Checks:
Applicability:
Description:
Specifications:
Current DHV Parameter = "NOXR"
NOXR Derived Hourly Status = true
Current DHV System Type = null
Current DHV Record = Current NOx Rate Derived Hourly Record
Current DHV Method = Current NOx Rate Method Code
NOx Emission Rate MODC = Current NOx Rate Derived Hourly Record. IVIodcCode
if {Current DHV Method == "CEM")
Current DHV System Type = "NOX"
else if (Current DHV Method == "PEM")
Current DHV System Type= "NOXP"
if (Current DHV Method == "AE")
Current DHV System Type = "NOXE"
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report NOx Emissions Rate Derived Hourly Evaluation
Environmental Protection Agency
Page 368 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURDHV-4
Check Name: Initialize C02 Derived Hourly Data
Related Former Checks:
Applicability:
Description:
Specifications:
Current DHV Parameter = "C02"
CO2 Derived Hourly Status = true
Current DHV Record = Current C02 Mass Derived Hourly Record
Current DHV Method = C02 Method Code
Current DHV System Type = null
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report C02 Mass Rate Derived Hourly Evaluation
Environmental Protection Agency
Page 369 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURDHV-5
Check Name: Initialize C02C Derived Hourly Data
Related Former Checks:
Applicability:
Description:
Specifications:
Current DHV Parameter = "C02C"
C02C Derived Hourly Status = true
Current DHV Record = Current C02 Cone Derived Hourly Record
Current DHV System Type = 'C02'
Current DHV Method = "CEM"
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report C02 Concentration Derived Hourly Evaluation
Environmental Protection Agency
Page 370 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURDHV-6
Check Name:
Initialize H20 Derived Hourly Data
Related Former Checks:
Applicability:
Description:
Specifications:
Current DHV Parameter = "H20"
H20 Derived Hourly Status = true
Current DHV Record = Current H20 Derived Hourly Record
Current DHV System Type= "H20"
Current DHV Method = H20 Method Code
RATA Status Required = false
Current Hourly Record for RA TA Status = Current H20 Derived Hourly Record
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report H20 Derived Hourly Evaluation
Environmental Protection Agency
Page 371 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURDHV-7
Check Name: Initialize HI Derived Hourly Data
Related Former Checks:
Applicability:
Description:
Specifications:
Current DHV Parameter = "HI"
HI Derived Hourly Status = true
Current DHV System Type = null
Current DHV Record = Current Heat Input Derived Hourly Record
Current DHV Method = Heat Input Method Code
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Heat Input Derived Hourly Evaluation
Environmental Protection Agency
Page 372 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURDHV-8
Check Name: Initialize S02R Derived Hourly Data
Related Former Checks:
Applicability:
Description:
Specifications:
Current DHV Parameter = "S02R"
S02R Derived Hourly Status = true
Current DHV System Type = null
Current DHV Record = Current S02R Derived Hourly Record
Current DHV Method = null
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report S02R Derived Hourly Evaluation
Environmental Protection Agency
Page 373 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURDHV-9
Check Name: Initialize S02M Derived Hourly Data
Related Former Checks:
Applicability:
Description:
Specifications:
Current DHV Parameter = "S02M"
S02M Derived Hourly Status = true
Current DHV System Type = null
Current DHV Method = "LME"
Current DHV Record = Current S02 Derived Hourly Record
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report S02M Derived Hourly Evaluation (LME)
Environmental Protection Agency
Page 374 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURDHV-10
Check Name:
Initialize NOXM Derived Hourly Data
Related Former Checks:
Applicability:
Description:
Specifications:
Current DHV Parameter = "NOXM"
NOXM Derived Hourly Status = true
Current DHV System Type = null
Current DHV Method = "LME"
Current DHV Record = Current NOx Mass Derived Hourly Record
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report NOXM Derived Hourly Evaluation (LME)
Environmental Protection Agency
Page 375 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURDHV-11
Check Name:
Initialize C02M Derived Hourly Data
Related Former Checks:
Applicability:
Description:
Specifications:
Current DHV Parameter = "C02M"
C02M Derived Hourly Status = true
Current DHV System Type = null
Current DHV Method = "LME"
Current DHV Record = Current C02 Mass Derived Hourly Record
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report C02M Derived Hourly Evaluation (LME)
Environmental Protection Agency
Page 376 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURDHV-12
Check Name: Initialize HIT Derived Hourly Data
Related Former Checks:
Applicability:
Description:
Specifications:
Current DHV Parameter = "HIT"
HIT Derived Hourly Status = true
Current DHV System Type = null
Current DHV Method = Heat Input Method Code
Current DHV Record = Current Heat Input Derived Hourly Record
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report HIT Derived Hourly Evaluation (LME)
Environmental Protection Agency
Page 377 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURDHV-13
Check Name: Check MODC in DHV Record
Related Former Checks:
Applicability:
Description:
Specifications:
Derived Hourly Mode Status = false
case {Current DHV Parameter)
S02: If (Current DHV Method == "AMS")
If (Current DHV Record. ModcCode is not null and is not in set {01, 02, 03, 04, 05, 06, 07, 08, 09, 10, 12, 13, 15,
16, 21, 23, 53, 54, 55})
return result A
Else
Derived Hourly Mode Status = true
else
If {Current DHV Record. ModcCode is not null)
return result B
Else
Derived Hourly Mode Status = true
NOX: If {Current DHV Method == "AMS")
If {Current DHV Record. ModcCode is not null and is not in set {01, 02, 03, 04, 05, 06, 07, 08, 09, 10, 11, 12, 13,
15, 21, 23, 24, 53, 54, 55})
return result A
Else
Derived Hourly Mode Status = true
else
If (Current DHV Record. ModcCode is not null)
return result B
Else
Derived Hourly Mode Status = true
NOXR: If {Current DHV Method == "AMS" AND Current DHV Record. ModcCode is null)
Derived Hourly Mode Status = true
else if {Current DHV Method == "AE")
If (Current DHV Record. ModcCode is not null)
return result C
Else
Derived Hourly Mode Status = true
else
if {Current DHV Record. ModcCode not in set {01, 02, 03, 04, 05, 06, 07, 08, 09, 10, 11, 12, 13, 14, 15, 21, 22,
23, 24, 25, 53, 54, 55})
return result A
Else
Derived Hourly Mode Status = true
C02C: If {Current DHV Record. ModcCode not in set {01, 02, 03, 04, 05, 06, 07, 08, 09, 10, 12, 21, 53, 54, 55})
return result A
Else
Derived Mode Status = true
C02: If {Current DHV Method == "AMS")
If {Current DHV Record. ModcCode is not null and is not in set {01, 02, 03, 04, 05, 06, 07, 08, 09, 10, 12, 53, 54,
Environmental Protection Agency
Page 378 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
55})
return result A
Else
Derived Hourly Mode Status = true
else
If (Current I)HV Record. ModcCode is not null)
return result B
Else
Derived Hourly Mode Status = true
HI: If {CurrentDHVMethod == "AMS")
If {Current DHV Record. ModcCode is not null and is not in set {01, 02, 03, 04, 05, 06, 07, 08, 09, 10, 12, 26, 53,
54, 55})
return result A
Else
Derived Hourly Mode Status = true
else
If {Current DHV Record. ModcCode is not null and Current DHV Record. ModcCode <> "26")
return result B
Else
Derived Hourly Mode Status = true
H20: H20DHVMODC = Current DHV Record. ModcCode
if {Current DHV Method == "MWD")
If {Current DHV Record. ModcCode not in set {01, 02, 03, 04, 05, 06, 07, 08, 09, 10, 12, 21, 53, 54, 55})
return result A
else
Derived Hourly Mode Status = true
else if {Current DHV Method == "MDF")
If (Current DHV Record. ModcCode <> "40")
return result A
else
Derived Hourly Mode Status = true
S02R: If {S02 F23 Method Active For Hour == true)
If {Current DHV Record. ModcCode <> "40")
return result A
else
Derived Hourly Mode Status = true
HIT: If {Current DHV Record. ModcCode == "45")
If {LME HI Substitute Data Code== "MHHI")
Derived Hourly Mode Status = true
else
return result D
else if {Current DHV Record. ModcCode is not null)
return result A
Else
Derived Hourly Mode Status = true
S02M, NOXM, C02M:
If {Current DHV Record. ModcCode is not null)
return result B
Else
Environmental Protection Agency
Page 379 of 850
-------
Draft ECMPS Emissions Check Specifications
Derived Hourly Mode Status = true
6/17/2015 12:00:00AM
Results:
Result
A
B
C
D
Response Severity
The MODCCode reported in the DHV record for [param] is invalid. Critical Error Level 1
You reported an MODCCode in the DHV record for [param]. This field should be Non-Critical Error
blank.
You reported an MODCCode in the DHV record for NOXR. This field should be blank Critical Error Level 1
when you use the Appendix E method to determine the NOx emission rate.
You reported an MODCCode of 45 in the DHV record for HIT, but you have not
reported a SubstituteDataCode of MHHI in the active heat input method record in your
monitoring plan.
Critical Error Level 1
Usage:
1
Process/Category:
Emissions Data Evaluation Report —
— C02 Concentration Derived Hourly Evaluation
2
Process/Category:
Emissions Data Evaluation Report —
— C02 Mass Rate Derived Hourly Evaluation
3
Process/Category:
Emissions Data Evaluation Report —
— C02M Derived Hourly Evaluation (LME)
4
Process/Category:
Emissions Data Evaluation Report —
— H20 Derived Hourly Evaluation
5
Process/Category:
Emissions Data Evaluation Report —
— Heat Input Derived Hourly Evaluation
6
Process/Category:
Emissions Data Evaluation Report —
— HIT Derived Hourly Evaluation (LME)
7
Process/Category:
Emissions Data Evaluation Report —
— NOx Emissions Rate Derived Hourly Evaluation
8
Process/Category:
Emissions Data Evaluation Report —
— NOx Mass Rate Derived Hourly Evaluation
9
Process/Category:
Emissions Data Evaluation Report —
— NOXM Derived Hourly Evaluation (LME)
10
Process/Category:
Emissions Data Evaluation Report —
— S02 Derived Hourly Evaluation
11
Process/Category:
Emissions Data Evaluation Report —
— S02M Derived Hourly Evaluation (LME)
12
Process/Category:
Emissions Data Evaluation Report —
— S02R Derived Hourly Evaluation
Environmental Protection Agency
Page 380 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURDHV-14
Check Name:
Check Percent Monitor Availability in DHV Record
Related Former Checks:
Applicability:
Description:
Specifications:
Derived Hourly Pma Status = false
Derived Hourly Missing Data Status = true
If (Derived Hourly Mode Status == true)
If ( Current DHV Record. PercentAvailable is NULL)
if {Current DHV Parameter not in set {H20, C02C, NOXR})
Derived Hourly Pma Status = true
else if {Current DHV Parameter == "NOXR" and Current DHV Method not in set {PEM, CEM})
Derived Hourly Pma Status = true
else if {Current DHV Parameter == "H20" and Current DHV Record. ModcCode == "40")
Derived Hourly Pma Status = true
if {Current DHV Record. ModcCode not in set {01, 02, 03, 04, 14, 21, 22, 53, 54} AND Legacy Data Evaluation
== true)
Derived Hourly Pma Status = true
return result A
else
return result B
else
if {Current DHV Parameter == "NOXR" and Current DHV Method == "AE")
return result C
else if {Current DHV Parameter == "H20" and Current DHV Record. ModcCode == "40")
return result C
else if {Current DHV Parameter not in set {H20, C02C, NOXR} AND Current DHV Method <> "AMS")
return result C
else if (Current DHV Record.PcrccnlAvcUh\b\c> 100.0 OR
Current DHV Record. Pc rcc lit Ay a i 1 ab 1 c < 0.0)
return result D
Else
case {Current DHV Record.ModcCode)
= 06: If CurrentDHVRecord.PercentAvailable >= 90.0
Derived Hourly Pma Status = true
Else
return result E
= 08: If Current DHV Record. PercentAvailable >= 95.0
Derived Hourly Pma Status = true
Else
return result E
= 09: If Current DHV Record .PercentAvailable >= 90.0 AND Current DHV Record. PercentAvailable < 95.0
Derived Hourly Pma Status = true
Else
return result E
else
Environmental Protection Agency
Page 381 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
= 10: If Current DHV Record PercentAvailable >=80.0 AND Current DHVRecord.PcrccntAyai 1 ab 1 c < 90.0
Derived Hourly Pma Status = true
Else If Current DHV Parameter == "NOXR" and Current DHV Record. PercentAvailable >=90.0
Derived Hourly Pma Status = true
return result F
Else
return result E
= 11: If Current DHV Record. PercentAvailable >=90.0
Derived Hourly Pma Status = true
Else
return result E
All other MODC Codes:
Derived Hourly Pma Status = true
Results:
Result
A
B
C
D
E
F
Response
You reported anMODCCode of [ModcCode] in the DHV record for [param], but you
did not report a value for PercentAvailable. While this is not required for legacy EDR
data, it is required in all [param] DHV records for ECMPS.
You did not report PercentAvailable in the DHV record for [param].
You reported PercentAvailable in the DHV record for [param]. This field should be
blank.
The PercentAvailable reported in the DHV record for [param] is invalid. This value
must be between 0 and 100.
You reported an MODCCode of [modcCode] in the DHV for [param], but the
PercentAvailable is not appropriate for this MODC.
You reported an MODCCode of 10 in the [type] record for [param], but the
PercentAvailability is greater than or equal to 90. When the PMA is greater than or
equal to 90, you should only report an MODC of 10 to indicate that you used the
maximum hourly value in the lookback period for the next available higher load bin,
because there were no quality-assured data in the bin corresponding to the current load
range. (See Part 75.33(c)(5).)
Severity
Informational Message
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Informational Message
Environmental Protection Agency
Page 382 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Usage:
1
Process/Category
2
Process/Category
3
Process/Category
4
Process/Category
5
Process/Category
6
Process/Category
7
Process/Category
8
Process/Category
9
Process/Category
10
Process/Category
11
Process/Category
12
Process/Category
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
C02 Concentration Derived Hourly Evaluation
C02 Mass Rate Derived Hourly Evaluation
C02M Derived Hourly Evaluation (LME)
H20 Derived Hourly Evaluation
Heat Input Derived Hourly Evaluation
HIT Derived Hourly Evaluation (LME)
NOx Emissions Rate Derived Hourly Evaluation
NOx Mass Rate Derived Hourly Evaluation
NOXM Derived Hourly Evaluation (LME)
S02 Derived Hourly Evaluation
S02M Derived Hourly Evaluation (LME)
S02R Derived Hourly Evaluation
Environmental Protection Agency
Page 383 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURDHV-15
Check Name: Check Prior QA'd Hours for MODC 07
Related Former Checks:
Applicability:
Description:
Specifications:
if (Derived Hourly Mode Status == true AND Derived Hourly PMA Status == true)
if (Current I)HV Record. ModcCodc == 07)
case (Current DHVParameter)
NOXR: MODC Set = {01, 02, 04, 14, 21, 22, 53}
C02C: MODC Set = {01, 02, 04, 21, 53}
H20: MODC Set = {01, 02, 04, 21, 53}
Prior QA Hours = count DerivedHourly ValueData records where
DerivedHourlyValueData.ModcCode in set MODC Set AND
DerivedHourlyValueData.ParameterCode = CurrentDHVRecord.ParamctcrCodc AND
(DerivedHourly ValueData.BeginDate < Current Date OR
(DerivedHourly ValueData.BeginDate = Current Date AND DerivedHourly ValueData.BeginHour < Current
Hour))
if (Current DHV Parameter == "NOXR")
if (Prior QA Hours > 2160)
Derived Hourly Missing Data Status = false
return result A
else
if (Prior QA Hours > 720)
Derived Hourly Missing Data Status = false
return result A
Results:
Result Response Severity
A You reported anMODCCode of 07 in the DHV record for [param], but too many prior Critical Error Level 1
quality assured hours exist in evaluation period for use of this missing data approach.
Usage:
1 Process/Category: Emissions Data Evaluation Report C02 Concentration Derived Hourly Evaluation
2 Process/Category: Emissions Data Evaluation Report H20 Derived Hourly Evaluation
3 Process/Category: Emissions Data Evaluation Report NOx Emissions Rate Derived Hourly Evaluation
Environmental Protection Agency
Page 384 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURDHV-16
Check Name:
Related Former Checks:
Check for Correct Use of Missing Data MODCs
Applicability:
Description:
Specifications:
Current DHVHBHA Value = null
if (Derived Hourly Mode Status == true AND Derived Hourly PMA Status == true)
case {Current DHV Parameter)
NOXR: MODCSet = {01, 02, 03, 04, 14, 21, 22, 53, 54}
C02C: MODCSet = {01, 02, 03, 04, 21, 53, 54}
H20: MODCSet = {01, 02, 03, 04, 21, 53, 54}
if (Current DHV Record.ModcCode in set {06, 08, 09})
If (Current MHVParameter in set {C02C, H20})
Prior Record = latest DerivedHourly ValueData record or MonitorHourly ValueData record where
ParameterCode = Current DHV Parameter AND
ModcCode in set MODC Set AND
(Date < Current Date OR
(Date = Current Date AND Hour < Current Hour ))
If Prior Record is not null and is in current reporting period
Next Record = earliest DerivedHourly ValueData record or MonitorHourly ValueData record where
Data.ParameterCode = Current MHV Parameter AND
Data.ModcCode in set MODC Set AND
(Date > Current Date OR
(Date = Current Date AND Hour > Current Hour ))
If Next Record is not null and is in current reporting period
If /Jr/V;rAdjustedHourly Value >= 0 AND TVex/.Record. AdjustedHourly Value >= 0
Current DHV HBHA Value = (Prior Record. Adj ustedHourly Value + Next
.Record. AdjustedHourly Value) / 2, ROUNDED to a single decimal.
else
Derived Hourly Missing Data Status = false
return result A
Prior DHV Record = latest DerivedHourly ValueData record where
DerivedHourly ValueData.ParameterCode = Current DHV Parameter AND
DerivedHourValueData.ModcCode in set MODC Set AND
[DerivedHourly ValueData.Date < Current Date OR
(DerivedHourly ValueData.Date = Current Date AND DerivedHourly ValueData.Hour < Current Hour )]
If Prior DHV Record is not null and is in current reporting period
else
Environmental Protection Agency
Page 385 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Next DHVRecord = earliest DerivedHourlyValueData record where
DerivedHourlyValueData.ParameterCode = Current MHVParameter AND
DerivedHourValueData.ModcCode in set MODC Set AND
[DerivedHourlyValueData.Date > Current Date OR
(DerivedHourlyValueData.Date = Current Date AND DerivedHourlyValueData.Hour > Current
Hour)]
If Next DHV Record is not null and is in current reporting period
If Prior DIP VtecwY/.AdjustcdHourlv Value >= 0 AND Xexi DIP Vfecort/.AdjustcdHourly Value
>=0
Current DHV HBHA Value = (Prior 1)11} VtecwY/.AdjustcdHourlv Value + Next DHV
.Record. AdjustedHourly Value) / 2, ROUNDED to three decimal places.
else
Derived Hourly Missing Data Status = false
return result A
else if {Current DHV Record. ModcCode == "11")
Prior Measured DHV Record = DerivedHourlyValueData record at latest time for the location where
DerivedHourlyValueData.ModcCode in set MODC Set AND
DerivedHourlyValueData.ParameterCode = Current DHV Parameter AND
(DerivedHourlyValueData.BeginDate < Current Date OR
(DerivedHourlyValueData.BeginDate = Current Date AND DerivedHourlyValueData.BeginHour < Current
Hour))
If Prior Measured DHV Record is not null and is in the current reporting period
PriorDate = Prior Measured DHVRecord.BeginDate
PriorHour = Prior Measured DHVRecordBsgmRour
else
PriorDate = the day prior to the beginning of the current reporting period
PriorHour = 23
Next Measured DHV Record = DerivedHourlyValueData record at earliest time for the location where
DerivedHourlyValueData.ModcCode in set MODC Set AND
DerivedHourlyValueData.ParameterCode = Current DHV Parameter AND
(DerivedHourlyValueData.BeginDate > Current Date OR
(DerivedHourlyValueData.BeginDate = Current Date AND DerivedHourlyValueData.BeginHour > Current
Hour))
If Next Measured DHV Record is not null and is in the current reporting period
NextDate = Next Measured DHV Record .BeginDate
NextHour = Next Measured DHV Record .BeginHour
else
NextDate = the day after the end of the current reporting period
NextHour = 0
Missing Data Period Length = Count of DerivedHourlyValueData records for the location where
DerivedHourlyValueDataParameterCode = Current DHV Parameter AND
(DerivedHourly ValueData.BeginDate > PriorDate OR
(DerivedHourly ValueData.BeginDate = PriorDate AND DerivedHourly ValueData.BeginHour >
PriorHour)) AND
(DerivedHourly ValueData.BeginDate < NextDate OR
(DerivedHourly ValueData.BeginDate = NextDate AND DerivedHourly ValueData.BeginHour <
NextHour))
Environmental Protection Agency
Page 386 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
if (Current DHV Record.FercentAvmlable is null OR Current DHVRecord. PercentA\ ailable >= 95.0)
if (Missing Data Period Length > 24)
Derived Hourly Missing Data Status = false
return result B
else
if (Missing Data Period Length > 8)
Derived Hourly Missing Data Status = false
return result B
Results:
Result
A
B
Usage:
1
2
3
Response Severity
The AdjustedHourly Value reported in the DHV record for [param] either before or after Critical Error Level 1
the current hour is invalid.
You reported an MODCCode of 11 in the DHV record for [param], but the length of Critical Error Level 1
the missing data period exceeds the allowable value for use of this missing data
procedure.
Process/Category:
Process/Category:
Process/Category:
Emissions Data Evaluation Report C02 Concentration Derived Hourly Evaluation
Emissions Data Evaluation Report H20 Derived Hourly Evaluation
Emissions Data Evaluation Report NOx Emissions Rate Derived Hourly Evaluation
Environmental Protection Agency
Page 387 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURDHV-17
Check Name:
Check Extraneous Data in DHV Record
Related Former Checks:
Applicability:
Description:
Specifications:
Derived Hourly Null Status = false
Hourly Extraneous Fields = null
if (Current DHV Record X) litidjustedHourly Vtilue is not null)
append "UnadjustedHourly Value" to Hourly Extraneous Fields
if (Current DHV Record.ScgmcnVSiumbcx is not null)
append "SegmentNumber" to Hourly Extraneous Fields
if (Current /)//K/?6'cwY/.OperatingConditionCode is not null)
if {Current DHV Parameter is not equal to "NOXM")
append "OperatingConditionCode" to Hourly Extraneous Fields
if (Current DHV Record. Flie ICodc is not null)
if {Current DHV Parameter not in set {N0XM,S02M,C02M})
append "FuelCode" to Hourly Extraneous Fields
if {Hourly Extraneous Fields is not null)
return result A
else
Derived Hourly Null Status = true
Results:
Result
A
You reported [fieldnames] in the DHV record for [param]. This data should be blank. Non-Critical Error
Response
Severity
Environmental Protection Agency
Page 388 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Usage:
1
Process/Category
2
Process/Category
3
Process/Category
4
Process/Category
5
Process/Category
6
Process/Category
7
Process/Category
8
Process/Category
9
Process/Category
10
Process/Category
11
Process/Category
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
C02 Concentration Derived Hourly Evaluation
C02 Mass Rate Derived Hourly Evaluation
C02M Derived Hourly Evaluation (LME)
H20 Derived Hourly Evaluation
Heat Input Derived Hourly Evaluation
HIT Derived Hourly Evaluation (LME)
NOx Mass Rate Derived Hourly Evaluation
NOXM Derived Hourly Evaluation (LME)
S02 Derived Hourly Evaluation
S02M Derived Hourly Evaluation (LME)
S02R Derived Hourly Evaluation
Environmental Protection Agency
Page 389 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURDHV-18
Check Name: Check System in DHV Record
Related Former Checks:
Applicability:
Description:
Specifications:
Current DHVMon Sys Record = null
Derived Hourly System Status = false
if {Current DHV Parameter == "NOXR")
App E Constant Fuel Mix = false
If {{Current DHV Parameter in set {S02, S02R, NOX, C02} AND Current DHV Method <> "AMS") OR
{Current DHV Parameter == "HI" AND Current DHV Method in set {CALC, AD, ADCALC}) OR
{Current DHV Parameter == "H20" AND Current DHV Method == "MDF") OR
LME HI Method is not null)
if Current DHV Record Momtoxmg'iystQvaiD is NOT null
return result A
else
Derived Hourly System Status = true
else if {Current DHV Parameter <> "HI")
case {Current DHV Parameter)
NOXR: MODC Set ={01, 02, 03, 04, 14, 21, 22}
C02C: MODC Set ={01, 02, 03, 04, 21}
H20: MODC Set = {01, 02, 03, 04, 21}
If {Current DHV Record MomtormgSystQvaK) is null)
If {Current DHV Method == "AMS")
Derived Hourly System Status = true
Else If {Current DHV Method == "AE")
If Current DHV Record.0\~>cri\{\ngCo\\&\{\o\\CoAc is null
Derived Hourly System Status = true
else
return result J
Else If (Current DHV Record. ModcCode in set MODC Set)
return result C
else
Derived Hourly System Status = true
else
If {Derived Hourly MODC Status == true AND Current DHV Method in set { CEM, PEM, MWD } AND Current DHV
Record. ModcCode not in set {05, 53, 54} AND Current DHV Record. ModcCode not in set MODC Set)
return result B
else
Current DHV Mon Sys Record = find active MonitoringSy stemData record for location where
MonitoringSystemData.MonitoringSystemID = Current DHVTtecon/.MonitoringSystemID
Environmental Protection Agency
Page 390 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
if (Current DHVMon Sys Record is null)
return result D
else if (Derived MHVMon Sys Record. Sy stc mTy pcCodc <> Current DHV System Type)
return result E
else if (Current DHV Method == "AE" AND Hourly Fuel Flow Countfor Gas + Hourly Fuel Flow Countfor
Oil > 0)
If (Derived DHV Mon .Sys Record.Fvlc\Co&c. == 'MIX" OR Current DHV
Record. Ope rat i ngCo ndit io nCodc is not null)
if (Current DHV Record. OperatingConditionCode == "E")
return result F
else
App E Constant Fuel Mix = true
App E Reporting Method = "CONSTANT"
App E Reported Value = Current DHV Record. AdjustedHourly Value
App E Segment Number = Current DHV Record. SegmentNumber
App E Fuel Code = 'MIX"
App E NOXE System ID = Current DHV . IVIo n i t o ri ng Sy s t c m ID
App E NOXE System Identifier = Curren ?/.)// K . Sy s tc m I dc n t i fi c r
Derived Hourly System Status = true
if (Current DHV Record. OperatingConditionCode in set {X, Y, Z, U, W, N, M})
App E Op Code= Current DHV Record. Opc ra t i ngC'o nditio nCodc
if (Derived DHV Mon Sys Record.Vuc\CoAc <> "MIX")
return result G
else
return result H
else
return result I
else
Derived Hourly System Status = true
else
Derived Hourly System Status = true
Environmental Protection Agency
Page 391 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
A
B
C
D
E
F
H
I
Response
You reported [fieldnames] in the DHV record for [param]. This data should be blank.
You reported a MonitoringSystemID in the DHV record for [param]. This field should
be blank when missing data substitution is used.
You did not report a MonitoringSystemID in the DHV record for [param]. This
information is required when you report measured data.
You reported MonitoringSystemID [ID] in the DHV record for [param], but according
to your monitoring plan this system was not active during the hour.
You reported MonitoringSystemID [ID] in the DHV record for [param], but the
SystemTypeCode of this system is not appropriate.
You reported an OperatingConditionCode of E in the DHV record for NOXR. You
should report the NOx emission rate for emergency fuels in an HPFF record, not a
DHV record.
You reported an OperatingConditionCode in the DHV record for NOXR, which
indicates that you are determining NOx emission rate from a mixed fuel Appendix E
curve, but the FuelCode of NOXE MonitoringSystemID [ID] is not equal to "MIX". If
a NOXE system measures an individual fuel, the emissions from this system should be
reported in an HPFF record, not a DHV record.
The OperatingConditionCode reported in the DHV record for NOXR is missing or
invalid.
You reported NOXE MonitoringSystemID [ID] in the DHV record for NOXR, but the
FuelCode of this system is not equal to "MIX". If a NOXE system measures an
individual fuel, the emissions from this system should be reported in an HPFF record.
If this data represents unit-level emissions based on fuel-specific emissions data that
have been reported in one or more HPFF records, then the MonitoringSystemID should
be blank.
You reported an OperatingConditionCode in the DHV record for NOXR, which
indicates that you are determining NOx emission rate using Appendix E, but you did
not report a MonitoringSystemID in this record. If you determined the NOx emission
rate from a mixed fuel curve or via heat input apportionment, you should report the
MonitoringSystemID of the NOXE system for the curve. If you determined the NOx
emission rate from one or more individual fuel curves, you should not report an
OperatingConditionCode in the NOXR DHV record.
Severity
Non-Critical Error
Non-Critical Error
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 392 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Usage:
1
Process/Category
2
Process/Category
3
Process/Category
4
Process/Category
5
Process/Category
6
Process/Category
7
Process/Category
8
Process/Category
9
Process/Category
10
Process/Category
11
Process/Category
12
Process/Category
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
C02 Concentration Derived Hourly Evaluation
C02 Mass Rate Derived Hourly Evaluation
C02M Derived Hourly Evaluation (LME)
H20 Derived Hourly Evaluation
Heat Input Derived Hourly Evaluation
HIT Derived Hourly Evaluation (LME)
NOx Emissions Rate Derived Hourly Evaluation
NOx Mass Rate Derived Hourly Evaluation
NOXM Derived Hourly Evaluation (LME)
S02 Derived Hourly Evaluation
S02M Derived Hourly Evaluation (LME)
S02R Derived Hourly Evaluation
Environmental Protection Agency
Page 393 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURDHV-19
Check Name: Check System Designation Code for System in DHV Record
Related Former Checks:
Applicability:
Description:
Specifications:
If (Derived Hourly Mode Status == true AND Derived Hourly System Status == true AND Current DHVMon Sys Record is not null)
case (Current DHV Record. ModcCode)
01: If {Current DHV Mon Sys Record. SystemDesignationCode NOT in set {P, PB})
return result A
02: If {Current DHV Mon Sys Record. SystemDesignationCode NOT in set {B, RB, DB}
return result B
04: If {Current DHV Mon Sys Record. SystemDesignationCode <> "RM")
return result C
22: If {Current DHV Mon Sys Record. SystemDesignationCode <> "CI")
return result D
Results:
Result Response Severity
A You reported anMODCCode of [modcCode] in the DHV record for [param], but Critical Error Level 1
MonitoringSystemID [ID] is not a primary system.
B You reported anMODCCode of [modcCode] in the DHV record for [param], but Critical Error Level 1
MonitoringSystemID [ID] is not a backup system.
C You reported anMODCCode of [modcCode] in the DHV record for [param], but Critical Error Level 1
MonitoringSystemID [ID] is not a reference method system.
D You reported an MODCCode of 22 in the DHV record for NOXR, but Critical Error Level 1
MonitoringSystemID [ID] is not a certified inlet system.
Usage:
1 Process/Category: Emissions Data Evaluation Report C02 Concentration Derived Hourly Evaluation
2 Process/Category: Emissions Data Evaluation Report H20 Derived Hourly Evaluation
3 Process/Category: Emissions Data Evaluation Report NOx Emissions Rate Derived Hourly Evaluation
Environmental Protection Agency
Page 394 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURDHV-24
Check Name: Check Formula in DHV Record
Related Former Checks:
Applicability:
Description:
Specifications:
Derived Hourly Formula Status = false
Derived Hourly Equation Status = false
Current DHV Multiple Fuel Equation Code == null
Current DHV Formula Record = null
If (Current DHV Record Formula I DKcy is null)
If {Current DHV Method in set {AMS, LME}) OR
(Derived Hourly Mode Status == true AND Current DHV Record .ModcCode == "40") OR
LME HI Method is not null)
Derived Hourly Formula Status = true
else if (Current DHV Parameter = "AE" AND App E Constant Fuel Mix == true)
Derived Hourly Formula Status = true
else if (Current DHV Parameter in set {NOXR, S02, HI, C02}) AND Current DHV Method in set {AD, AE})
Derived Hourly Formula Status = true
If (Hourly Fuel Flow Count for Gas + Hourly Fuel Flow Count for Oil >1)
case (Current DHV Parameter)
NOXR: Current DHV Multiple Fuel Equation Code = "E-2"
S02: Current DHV Multiple Fuel Equation Code = "D-12"
C02: Current DHV Multiple Fuel Equation Code = "G-4 A"
HI: Current DHV Multiple Fuel Equation Code = "D-15A"
Locate active Formula Record for location WHERE
ParameterCode == Current DHV Parameter AND
EquationCode == Current DHV Multiple Fuel Equation Code
If found,
If (Legacy Data Evaluation == true)
return result A
else
return result B
else if (Current DHV Method = "PEM")
Derived Hourly Formula Status = true
else if (Current DHV Parameter == "NOX" AND Current NOx Rate Method Code == "AE" AND Hourly Fuel Flow Count for
Gas + Hourly Fuel Flow Count for Oil > 1 AND Legacy Data Evaluation == true)
Derived Hourly Formula Status = true
else if (Current DHV Parameter in set {NOXR, H20, C02C})
If (Derived Hourly Mode Status == true)
If (Current DHV Record ModcCode in set {01, 02, 03, 04, 05, 14, 21, 22, 53, 54})
return result C
else
Derived Hourly Formula Status = true
else
return result C
Environmental Protection Agency
Page 395 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
else
If {CurrentDHVParameter in set {S02R, H20} AND CurrentDHVRecord.MODCCode == "40")
return result D
else if (LME HI Method is not null)
return result J
else
Current DHV Formula Record= Find MonitoringFormulaData record where
MonitoringFormulaData,MonitoringFormulaIDKey = Current DHV Record. Fo rm u 1 a ID K ey
If {Current DHV Formula Record is null)
return result E
else if {Current DHV Formula Record. ParameterCode is not equal to Current DHV Parameter)
If Current DHV Parameter == "HI" AND Current DHV Method = "AD" AND Hourly Fuel Flow Count for Gas
+ Hourly Fuel Flow Count for Oil > 1 AND Current DHV Formula Record. Para mctc rCodc == "HIT" AND
Current DHV Formula Record. E q ua t i o n C o dc == "D-15" AND Legacy Data Evaluation == true)
return result I
else
return result F
else
Derived Hourly Formula Status = true
if Current DHV Parameter == "HI" AND Current DHV Method = "ADCALC" and Current DHV Formula
Record. EquationCodc not in {F-21A,F-21B,F-2ID}
Count all active MonitoringFormulaData record for location where
EquationCode in {F-21A,F-21B,F-21D}
if (Count =1)
Current DHV Formula Record = Find active MonitoringFormulaData record for location where
EquationCode in {F-21A,F-21B,F-21D}
else if {Current DHV Method == "AE")
if (App E Constant Fuel Mix == true OR Hourly Fuel Flow Count for Gas + Hourly Fuel Flow Count
for Oil == 0)
return result H
else if {Derived Hourly Mode Status == true)
ff {Current DHV Parameter in set {NOXR, H20, C02C} AND Current DHV Record. MODCCode NOT
in set {01, 02, 03, 04, 05, 14, 21, 22, 53, 54} AND Legacy Data Evaluation == false)
return result G
Environmental Protection Agency
Page 396 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
Results:
Result Response
A You did not report a FormulalD in the DHV record for [param]. While this is
acceptable for legacy EDR data, the FormulalD will be required for ECMPS.
B You did not report a FormulalD in the DHV record for [param]. This formula is
required when you burn multiple fuels during the hour.
C You did not report a FormulalD in the DHV record for [param].
D You reported an MODC of 40, but you reported a FormulalD in the DHV record for
[param]. This field should be blank when reporting a default value.
E You reported FormulalD [ID] in the DHV record for [param], but there is no active
Formula record for this formula in your monitoring plan.
F You reported FormulalD [ID] in the DHV record for [param], but this is not a [param]
formula.
G You reported a FormulalD in the DHV record for [param]. This field should be blank
when using missing data substitution.
H You reported a FormulalD in the DHV record for NOXR. This field should be blank
unless you determine the NOX emission rate using multiple Appendix E curves.
I You reported FormulalD [ID] in the DHV record for HI, but FormulaCode D-15 will
no longer be appropriate for calculating HI from multiple fuels. For ECMPS, the
ParameterCode should be for this formula should be HI and the FormulaCode should I
"D-15A".
J You reported a FormulalD in the DHV record for [param]. This field should be blank
when reporting emissions for LME units.
Usage:
1
Process/Category:
Emissions Data Evaluation Report —
— C02 Concentration Derived Hourly Evaluation
2
Process/Category:
Emissions Data Evaluation Report —
— C02 Mass Rate Derived Hourly Evaluation
3
Process/Category:
Emissions Data Evaluation Report —
— C02M Derived Hourly Evaluation (LME)
4
Process/Category:
Emissions Data Evaluation Report —
— H20 Derived Hourly Evaluation
5
Process/Category:
Emissions Data Evaluation Report —
— Heat Input Derived Hourly Evaluation
6
Process/Category:
Emissions Data Evaluation Report —
— HIT Derived Hourly Evaluation (LME)
7
Process/Category:
Emissions Data Evaluation Report —
— NOx Emissions Rate Derived Hourly Evaluation
8
Process/Category:
Emissions Data Evaluation Report —
— NOx Mass Rate Derived Hourly Evaluation
9
Process/Category:
Emissions Data Evaluation Report —
— NOXM Derived Hourly Evaluation (LME)
10
Process/Category:
Emissions Data Evaluation Report —
— S02 Derived Hourly Evaluation
11
Process/Category:
Emissions Data Evaluation Report —
— S02M Derived Hourly Evaluation (LME)
12
Process/Category:
Emissions Data Evaluation Report —
— S02R Derived Hourly Evaluation
Severity
Informational Message
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Non-Critical Error
Critical Error Level 1
Informational Message
Critical Error Level 1
Environmental Protection Agency
Page 397 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURDHV-25
Check Name: Check Heat Input Equation Code
Related Former Checks:
Applicability:
Description:
Specifications:
CO 2 Cone Checks Needed for Heat Input = false
02 Wet Checks Needed for Heat Input = false
02 Dry Checks Needed for Heat Input = false
if (Heat Input App D Method Active For Hour == true)
Hourly Fuel Flow Checks needed for Heat Input = true
else
Hourly Fuel Flow Checks needed for Heat Input = false
Heat Input Equation Code = null
if (Derived Hourly Formula Status == true)
if {Current DHVFormula Record is not null)
Heat Input Equation Code= Current DHV Formula Record. EquationCode
if (Heat Input CEM Method Active For Hour == true)
if (Heat Input Equation Code in set {F-15, F-16, F-17, F-18} )
Derived Hourly Equation Status = true
Flow Monitor Hourly Checks Needed = true
if (Heat Input Equation CodeO "F-15")
Moisture Needed = true
append "MIN" to H20 Missing Data Approach
if (Heat Input Equation Code = "F-15" OR Heat Input Equation Code = "F-16")
CO2 Cone Checks Needed for Heat Input = true
FC Factor Needed = true
else if (Heat Input Equation Code= "F-17")
02 Wet Checks Needed for Heat Input = true
FD Factor Needed = true
else if (Heat Input Equation Code = "F-18")
02 Dry Checks Needed for Heat Input = true
FD Factor Needed = true
else if (Heat Input Equation Code is null)
return result A
else
return result B
else if (Heat Input App D Method Active For Hour == true)
if (Heat Input Equation Code== "D-15A")
Derived Hourly Equation Status = true
else if (Heat Input Method Code == "ADCALC" and Heat Input Equation Code in set {F-21A, F-21B, F-21C,
F-21D, F-25})
Derived Hourly Equation Status = true
if (Heat Input Equation Code== "F-21D")
Apportionment HI Method Array for the location= "NOCALC"
elseif (Heat Input Equation Code in set {F-19, F-19V, F-20, D-6, D-8} AND (Legacy Data Evaluation == true
OR Hourly Fuel Flow Count for Gas + Hourly Fuel Flow Count for Oil == 1))
Derived Hourly Equation Status = true
return result C
else if (Heat Input Equation Code is null)
return result A
else
Environmental Protection Agency
Page 398 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
return result B
else if {CurrentDHVMethod in set {CALC, ADCALC})
if (Heat Input Equation Code in set {F-21A, F-21B, F-21C, F-25})
Derived Hourly Equation Status = true
else if (Heat Input Equation Code== "SS-3B")
Derived Hourly Equation Status = true
Apportionment HI Method Array for the location= "COMPLEX"
else if (Heat Input Equation Code== "F-21D" OR Current DHV Method == "ADCALC")
Derived Hourly Equation Status = true
Apportionment HI Method Array for the location= "NOCALC"
else if (Heat Input Equation Code is null)
return result A
else
return result B
else
Derived Hourly Equation Status = true
else
Derived Hourly Equation Status = true
Results:
Result
A
You reported FormulalD [ID] in the DHV record for [param], but you did not report a Critical Error Level 1
FormulaCode for this formula in your monitoring plan.
You reported FormulalD [ID] in the DHV record for HI, but the FormulaCode of this Critical Error Level 1
formula is not appropriate for calculating HI.
You reported FormulalD [ID] in the DHV record for HI, but a formula with a Informational Message
FormulaCode [EQCODE] is no longer appropriate in this record. For ECMPS, if you
are calculating heat input from multiple fuels using Appendix D, you should report a
formula with a FormulaCode of D-15A in the DHV record; otherwise, do not report a
FormulalD.
Response
Severity
B
C
Usage:
1 Process/Category: Emissions Data Evaluation Report Heat Input Derived Hourly Evaluation
Environmental Protection Agency
Page 399 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURDHV-26
Check Name: Check NOX Equation Code
Related Former Checks:
Applicability:
Description:
Specifications:
NOx Rate Checks Neededfor NOx Mass Calc = false
Heat Input Checks Needed for NOx Mass Calc = false
NOx Mass Equation Code = null
if (Derived Hourly Formula Status == true)
if (Current DHVFormula Record is not null)
NOx Mass Equation Code= Current DHV Formula Record. EquationCode
if (Current DHV Method == "CEM")
if (NOx Mass Equation Code in set {F-26A, F-26B} )
Derived Hourly Equation Status = true
Flow Monitor Hourly Checks Needed = true
if (NOx Mass Equation Code= "F-26B") // note that the old name fortius formula was "N-2"
Moisture Needed = true
append "MIN" to H20 Missing Data Approach
else if (NOx Mass Equation Code is null)
return result A
else
return result B
else if (Current DHV Method == "NOXR")
if (NOx Mass Equation Code== "F-24A")
Derived Hourly Equation Status = true
Heat Input Checks Needed for NOx Mass Calc = true
Nox Rate Checks Neededfor NOx Mass Calc = true
else if (NOx Mass Equation Code is null)
return result A
else
return result C
else
Derived Hourly Equation Status = true
else
Derived Hourly Equation Status = true
if (Current NOx Rate Method Code == "AE" AND Hourly Fuel Flow Count for Gas + Hourly Fuel Flow Countfor Oil
> 1 AND Legacy Data Evaluation == true)
NOx Mass Equation Code= "F-24A"
Environmental Protection Agency
Page 400 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result Response Severity
A You reported FormulalD [ID] in the DHV record for [param], but you did not report a Critical Error Level 1
FormulaCode for this formula in your monitoring plan.
B You reported FormulalD [ID] in the DHV record for NOX, but the FormulaCode of this Critical Error Level 1
formula is not appropriate for calculating NOX from a NOXC system.
C You reported FormulalD [ID] in the DHV record for NOX, but the FormulaCode of this Critical Error Level 1
formula is not appropriate for calculating NOX from a NOx-diluent system.
Usage:
1 Process/Category: Emissions Data Evaluation Report NOx Mass Rate Derived Hourly Evaluation
Environmental Protection Agency
Page 401 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURDHV-27
Check Name: Check NOXR Equation Code
Related Former Checks:
Applicability:
Description:
Specifications:
02 Dry Checks Neededfor NOx Rate Calc = false
02 Wet Checks Neededfor NOx Rate Calc = false
CO2 Diluent Checks Neededfor NOx Rate Calc = false
if {CurrentDHVMethod == "AE")
Hourly Fuel Flow Needed for NOx Rate Calc = true
else
Hourly Fuel Flow Needed for NOx Rate Calc = false
NOx Rate Equation Code= "" // null string
if (Derived Hourly Formula Status == true)
if {Current DHV Formula Record is not null)
NOx Rate Equation Code= Current DHV Formula Record. EquationCode
if {Current NOx Rate Method Code == "CEM")
if {NOx Rate Equation Code in set {19-1, 19-2, 19-3, 19-3D, 19-4, 19-5, 19-5D, 19-6, 19-7, 19-8, 19-9, F-5, F-6}
)
Derived Hourly Equation Status = true
ff {Current DHV Record.ModcCode in set {01, 02, 03, 04, 05, 14, 21, 22, 53, 54})
if {NOx Rate Equation Code in set {19-1, 19-4, F-5} )
02 Dry Checks Neededfor NOx Rate Calc = true
FD Factor Needed = true
else if {NOx Rate Equation CWeinset {19-3, 19-5} )
02 Wet Checks Neededfor NOx Rate Calc = true
FD Factor Needed = true
else if {NOx Rate Equation Code in set {19-3D, 19-5D})
FD Factor Needed = true
else if {NOx Rate Equation Code inset {19-6, 19-7, 19-8, 19-9, F-6} )
CO2 Diluent Checks Neededfor NOx Rate Calc = true
FC Factor Needed = true
else if {NOx Rate Equation Code == "19-2")
02 Wet Checks Neededfor NOx Rate Calc = true
FW Factor Needed = true
if {NOx Rate Equation Code in set {19-3, 19-3D, 19-4, 19-8}
Moisture Needed = true
append "MAX" to H20 Missing Data Approach
else if (NOx Rate Equation Code in set {19-5. 19-9}
Moisture Needed = true
append "MIN" to H20 Missing Data Approach
else (if {NOx Rate Equation Code is null)
Environmental Protection Agency
Page 402 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
else
return result A
else
return result B
else if {Current NOx Rate Method Code == "AE")
if (NOx Rate Equation Code == 'E-2')
Derived Hourly Equation Status = true
else if (NOx Rate Equation Code is null)
return result A
else
return result C
else
Derived Hourly Equation Status = true
Derived Hourly Equation Status = true
Results:
Result
A
B
C
Response
You reported FormulalD [ID] in the DHV record for [param], but you did not report a
FormulaCode for this formula in your monitoring plan.
You reported FormulalD [ID] in the DHV record for NOXR, but the FormulaCode of
this formula is not appropriate for calculating NOXR.
You reported FormulalD [ID] in the DHV record for NOXR, but the FormulaCode of
this formula is not appropriate for calculating NOXR from multiple fuels. The
FormulaCode should be E-2.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1
Process/Category: Emissions Data Evaluation Report NOx Emissions Rate Derived Hourly Evaluation
Environmental Protection Agency
Page 403 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURDH V-28
Check Name:
Check C02C Equation Code
Related Former Checks:
Applicability:
Description:
Specifications:
CO 2 Cone CEM Equation Code = "" // null string
if (Derived Hourly Formula Status == true)
if {Current DHVFormula Record is not null)
CO2 Cone CEM Equation Code = Current DHV Formula Record. FormulaCode
if (CO2 Cone CEM Equation Code in set {F-14A, F-14B})
Derived Hourly Equation Status = true
else
return result A
else
Derived Hourly Equation Status = true
Results:
Result
A
Response
You reported FormulalD [ID] in the DHV record for C02C, but the FormulaCode of
this formula is not appropriate for calculating C02C.
Severity
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report C02 Concentration Derived Hourly Evaluation
Environmental Protection Agency
Page 404 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURDHV-29
Check Name: Check C02 Equation Code
Related Former Checks:
Applicability:
Description:
Specifications:
CO 2 Cone Checks Neededfor C02 Mass Calc = false
Use C02 Diluent Cap for Co2 Mass Calc = false
Use 02 Diluent Cap for Co2 Cone Calc = false
if (CO 2 App D Method Active For Hour == true)
Hourly Fuel Flow Checks Neededfor C02= true
else
Hourly Fuel Flow Checks Neededfor C02 = false
CO2 Mass Equation Code = "" // null string
if (Derived Hourly Formula Status == true)
if {Current DHVFormula Record is not null)
CO 2 Mass Equation Code = Current DHV Formula Record. F o rm u 1 a C ode
if (CO2 CEM Method Active For Hour == true)
Flow Monitor Hourly Checks Needed = true
CO2 Cone Checks Neededfor C02 Mass Calc = true
if (CO 2 Mass Equation Code== "F-2" OR CO 2 Mass Equation Code== "F-ll")
Derived Hourly Equation Status= true
If (C02 Mass Equation Code== 'F-2')
Moisture Needed = true
append "MIN" to H20 Missing Data Approach
if (Current DH V Record. D i 1 ucntCap I ndicato r == 1)
Use C02 Diluent Cap for Co2 Mass Calc = true
Use 02 Diluent Cap for Co2 Cone Calc = true
else
return result A
else if (CO2 App D Method Active For Hour == true)
if (CO2 Mass Equation Code == "G-4A")
Derived Hourly Equation Status= true
else if (CO2 Mass Equation Code== "G-4" AND (Legacy Data Evaluation == true OR Hourly Fuel Flow Count
for Gas+ Hourly Fuel Flow Count for Oil == 1))
Derived Hourly Equation Status= true
return result B
else
return result A
else
Derived Hourly Equation Status = true
else
Derived Hourly Equation Status= true
Environmental Protection Agency
Page 405 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
A
B
Usage:
1
Response
You reported FormulalD [ID] in the DHV record for C02, but the FormulaCode of this
formula is not appropriate for calculating C02.
You reported FormulalD [ID] in the DHV record for C02, but a formula with a
FormulaCode [EQCODE] is no longer appropriate in this record. For ECMPS, if you
are calculating C02 from multiple fuels using Appendix D, you should report a formula
with a FormulaCode of G-4A in the DHV record; otherwise, do not report a FormulalD.
Severity
Critical Error Level 1
Informational Message
Process/Category: Emissions Data Evaluation Report C02 Mass Rate Derived Hourly Evaluation
Environmental Protection Agency
Page 406 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURDHV-30
Check Name: Check S02 Equation Code
Related Former Checks:
Applicability:
Description:
Specifications:
SO2 Monitor Hourly Checks Needed = false
if (S02 App D Method Active For Hour == true)
Hourly Fuel Flow Checks Needed for SQ2 = true
else
Hourly Fuel Flow Checks Needed for SQ2 = false
SOI Equation Code = "" // null string
if (Derived Hourly Formula Status == true)
If {Current DHVFormula Record is not null)
SO2 Equation Code= Current DHV Formula Record. FormulaCode
if (SO2 CEM Method Active For Hour == true)
if (SO2 Equation Code== "F-l" OR S02 Equation Code == "F-2")
Derived Hourly Equation Status = true
Flow Monitor Hourly Checks Needed = true
If (SO2 Equation Code== "F-2")
Moisture Needed = true
append "MIN" to H20 Missing Data Approach
if (S02 Monitor Hourly Count == 0)
return result A
else
SO2 Monitor Hourly Checks Needed = true
else if (S()2 Equation Code== "F-23" AND SO2 F23 Method Active For Hour == true)
Derived Hourly Equation Status = true
else
return result B
else if (S()2 F23 Method Active For Hour == true)
if (S()2 Equation Code== "F-23")
Derived Hourly Equation Status = true
else
return result B
else if (S()2 App D Method Active For Hour == true)
if (S()2 Equation Code= "D-12")
Derived Hourly Equation Status = true
else if (S()2 Equation Code in {D-2, D-4, D-5} AND Hourly Fuel Flow Count for Gas + Hourly Fuel Flow
Countfor Oil == 1))
Derived Hourly Equation Status = true
return result C
else
return result B
else
Derived Hourly Equation Status = true
else
Derived Hourly Equation Status = true
Environmental Protection Agency
Page 407 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
A
B
C
Usage:
1
Response
You did not report an MHV record for [param] for the hour.
You reported FormulalD [ID] in the DHV record for S02, but the FormulaCode of this
formula is not appropriate for calculating S02.
You reported FormulalD [ID] in the DHV record for S02, but a formula with a
FormulaCode [EQCODE] is not appropriate in this record. If you are calculating S02
from multiple fuels using Appendix D, you should report a formula with a
FormulaCode of D-12 in the DHV record; otherwise, do not report a FormulalD.
Process/Category: Emissions Data Evaluation Report S02 Derived Hourly Evaluation
Severity
Critical Error Level 1
Critical Error Level 1
Informational Message
Environmental Protection Agency
Page 408 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURDHV-31
Check Name:
Check H20 Equation Code
Related Former Checks:
Applicability:
Description:
Specifications:
H20 CEM Equation Code = "" // null string
if (Derived Hourly Formula Status == true)
If {Current DHVFormula Record is not null)
H20 CEM Equation Code = Current DHV Formula Record. FormulaCode
if CH20 CEM Equation Code in set (F-31, M-1K)
Derived Hourly Equation Status = true
else
return result A
else
Derived Hourly Equation Status = true
Results:
Result
A
You reported FormulalD [ID] in the DHV record for H20, but the FormulaCode of this Critical Error Level 1
formula is not appropriate for calculating H20.
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report H20 Derived Hourly Evaluation
Environmental Protection Agency
Page 409 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURDHV-32
Check Name: Verily Correct Reporting of NOXC MHV Record
Related Former Checks:
Applicability:
Description:
Specifications:
If {CurrentDHVMethod in set {CEM, CEMNOXR})
If {Current DHV Parameter == "NOXR")
Nox Cone Neededfor NOx Rate Calc = false
If Current DHV Record. ModcCodc in set {01, 02, 03, 04, 14, 21, 22, 53, 54} // only need cone for measured data
If {NOx Cone Monitor Hourly Count == 0)
return result A
else
Nox Cone Needed for NOx Rate Calc = true
else
If {NOx Cone Monitor Hourly Count == 1 AND Nox Cone Needed for NOx Mass Calc == false)
return result B
Else if {Current DHV Parameter == "NOX")
Nox Cone Needed for NOx Mass Calc = false
If {Derived Hourly Equation Status == true AND NOx Mass Equation Code begins with "F-26")
if {NOx Cone Monitor Hourly Count == 0)
return result A
else
Nox Cone Needed for NOx Mass Calc = true
Results:
Result
A
B
Response
You did not report an MHV record for NOXC for the hour.
You reported an MHV record for NOXC, but you reported a MODCCode of [mode] in
the DHV record for NOXR. You should not report an MHV record for NOXC when
you use substitute data to determine the NOx emission rate.
Severity
Critical Error Level 1
Non-Critical Error
Usage:
1
Process/Category: Emissions Data Evaluation Report NOx Emissions Rate Derived Hourly Evaluation
Process/Category: Emissions Data Evaluation Report NOx Mass Rate Derived Hourly Evaluation
Environmental Protection Agency
Page 410 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURDHV-33
Check Name: Determine Default Value for MODC 40
Related Former Checks:
Applicability:
Description:
Specifications:
Derived Hourly Default Status == true
If (Derived Hourly Mode Status == true AND Current DHVRecord.ModcCode == 40)
If {Current DHV Parameter == "H20")
If Current /)//K/?6'cwY/.AdjustcdHourly Value is null OR
Current /)//K/?6'cwY/.AdjustcdHourly Value <= 0 OR
Current /)//K/?6'cwY/.AdjustedHourly Value >= 100
Derived Hourly Default Status == false
return result A
If H20 Default Max Value is null
If (H20 Default Value > 0 AND H20 Default Value < 100)
if (Current DHV Record. AdjustedHourlyValue <> H20 Default Value)
Derived Hourly Default Status == false
return result B
else if (H20 Default Max Value > 0 AND H20 Default Max Value <100 AND H20 Default Min Value > 0 AND H20
Default Min Value < 100)
If Current DHV Record. Adj\istedHo\irlyVal\ie H20 Default Max Value)
Derived Hourly Default Status == false
return result C
Else
H20 Default Value = Current DHV Record. Ad^u^cdHourhV^uc
Else if (Current DHV Parameter == "S02R")
If Current /)//K/?6'cwY/.AdjustedHourly Value is null OR
Current /)//K/?6'cwY/.AdjustedHourly Value <= 0
Derived Hourly Default Status == false
return result D
If F23 Default Max Value is null
If (F23 Default Value > 0)
if (Current DHV/?£?6Y>/Y/,AdjustcdHourly Value <> F23 Default Value)
Derived Hourly Default Status == false
return result B
else if (F23 Default Max Value > 0 AND F23 Default Min Value > 0)
If Current DHV Record. AdjustedHowlyVaiue F23 Default Max Value)
Derived Hourly Default Status == false
return result C
Else
F23 Default Value = Current DHV Record. Ad) ustcdHourly Value
Environmental Protection Agency
Page 411 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
A
B
C
D
Usage:
1
Response
The AdjustedHourly Value reported in the DHV record for [param] is invalid. The
value must be between 0 and 100.
You reported an MODCCode of 40 in the DHV record for [param], but the
AdjustedHourly Value is not equal to the active default value in your monitoring plan.
You reported an MODCCode of 40 in the DHV record for [param], but the
AdjustedHourly Value is outside the range of the active default values in your
monitoring plan.
The AdjustedHourly Value reported in the DHV record for [param] is invalid. The
value must be greater than 0.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Process/Category: Emissions Data Evaluation Report H20 Derived Hourly Evaluation
Process/Category: Emissions Data Evaluation Report S02R Derived Hourly Evaluation
Environmental Protection Agency
Page 412 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
HOURDHV-34
Determine Derived Hourly Record Status
Check Code:
Check Name:
Related Former Checks:
Applicability:
Description:
Specifications:
If {Current DHVParameter == "NOXR")
Current NOX System Status = Derived Hourly System Status
Current NOXR HBHA Value = Current DHVHBHA Value
else if (Current DHV Parameter == "C02C")
Current C02C DHV HBHA Value = Current DHV HBHA Value
else if (Current DHV Parameter == "H20")
Current H20 DHV HBHA Value = Current DHV HBHA Value
If (Derived Hourly Mode Status == false OR Derived Hourly Equation Status == false OR Derived Hourly Missing Data Status == false
OR (Current DHV Record. MODCCode in set {06, 07, 08, 09, 10, 11) AND Derived Hourly Pma Status == false))
Case (Current DHV Parameter)
S02: SO2 Derived Hourly Status = false
NOXR: NOXR Derived Hourly Status = false
NOX: NOX Derived Hourly Status = false
C02: CO2 Derived Hourly Status = false
HI: HI Derived Hourly Status = false
C02C: C02C Derived Hourly Status = false
H20: H20 Derived Hourly Status = false
S02R: S02R Derived Hourly Status = false
S02M: S02M Derived Hourly Status = false
NOXM: NOXM Derived Hourly Status = false
C02M: C02M Derived Hourly Status = false
HIT: HIT Derived Hourly Status = false
Results:
Result
Response
Severity
Environmental Protection Agency
Page 413 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Usage:
1
Process/Category:
Emissions Data Evaluation Report
2
Process/Category:
Emissions Data Evaluation Report
3
Process/Category:
Emissions Data Evaluation Report
4
Process/Category:
Emissions Data Evaluation Report
5
Process/Category:
Emissions Data Evaluation Report
6
Process/Category:
Emissions Data Evaluation Report
7
Process/Category:
Emissions Data Evaluation Report
8
Process/Category:
Emissions Data Evaluation Report
C02 Concentration Derived Hourly Evaluation
C02 Mass Rate Derived Hourly Evaluation
H20 Derived Hourly Evaluation
Heat Input Derived Hourly Evaluation
NOx Emissions Rate Derived Hourly Evaluation
NOx Mass Rate Derived Hourly Evaluation
S02 Derived Hourly Evaluation
S02R Derived Hourly Evaluation
Environmental Protection Agency
Page 414 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURDHV-36
Check Name:
NOx Rate DHV Extraneous Fields Check
Related Former Checks:
Applicability:
Description:
Specifications:
Hourly Extraneous Fields = null
if (Current DHV Method <> " AE" OR (Hourly Fuel Flow Countfor Gas + Hourly Fuel Flow Countfor Oil > 0 AND App E Constant
Fuel Mix == false)
if (Current DHV Record. ScgmcntNumbcr is not null)
append "SegmentNumber" to Hourly Extraneous Fields
if (Current DHV Record. Ope rat i ngCo ndit io nCodc is not null)
if {Current DHV Method <> "LME")
if (Current DHV Record. Fuc\Codc is not null)
append "FuelCode" to Hourly Extraneous Fields
if (Hourly Extraneous Fields is not null),
return result A
append "OperatingConditionCode" to Hourly Extraneous Fields
Results:
Result
A
You reported [fieldnames] in the DHV record for [param]. This data should be blank. Non-Critical Error
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report NOx Emissions Rate Derived Hourly Evaluation
Environmental Protection Agency
Page 415 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURDHV-37
Check Name: Calculate Heat Input for LME Unit
Related Former Checks:
Applicability:
Description:
Specifications:
HIT Calculated Adjusted Value = null
If (Derived Hourly Mode Status == true)
if {LME HI Method is equal to "MHHI" OR Current I) HV Record. MODCCodc = "45")
Locate all Monitor Default records for the hour and location where the ParameterCode is equal to "MHHI".
If (one record is found, AND Monitor Default. Default Value is greater than 0, AND Monitor
Default.DefaultUnitsOfMcasurcCode is equal to "MMBTUHR")
If {Current Hourly Op Record .OpT\mc is greater than 0 and less than or equal to 1)
Calculate HIT Calculated Adjusted Value = DefaultValue * Current Hourly Op Record .OpWmc.
rounded to one decimal place.
else
return result A
else if {LME HI Method is equal to "LTFF")
If {LME CP Total Heat Input is greater than or equal to 0, AND LME Total Heat Input Array for the location is greater
than or equal to 0, AND Current Hourly Op Record. HourLoad is greater than or equal to 0, AND Current Hourly Op
Record.OpTime is greater than 0 and less than or equal to 1)
If {LME OS is equal to true, AND the Quarter of the Current Reporting Period is equal to 2)
If the Current Month is April,
If {LME April Load is greater than 0)
If (HourLoad is equal to 0)
Set HIT Calculated Adjusted Value = 0
else
Calculate HIT Calculated Adjusted Value = {LME CP April Heat Input *
Current Hourly Op Record.HourLoad * Current Hourly Op Record.OpTime /
LME April Load) + {LME April Heat Input Array for the location * Current
Hourly Op Record.HourLoad * Current Hourly Op Record. OpTime / LME
April Load Array for the location), and round the result to 1 decimal place.
else if {LME April Optime is greater than 0)
Calculate HIT Calculated Adjusted Value = {LME CP April Heat Input * Current
Hourly Op Record:OpTime / LME April Optime) + {LME April Heat Input Array for
the location * Current Hourly Op Record OpTime / LME April OpTime Array for the
location), and round the result to 1 decimal place.
Otherwise,
If {LME Total Load is greater than 0)
If (HourLoad is equal to 0)
Environmental Protection Agency
Page 416 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Set HIT Calculated Adjusted Value = 0
else
Calculate HIT Calculated Adjusted Value = ((LME CP Total Heat Input -
LME CP April Heat Input) * Current Hourly Op Record. HourLoad * Current
Hourly Op Record. OpTime / (LME Total Load - LME April Load)) + {{LME
Total Heat Input Array for the location - LME April Heat Input Array for the
location) * Current Hourly Op Record.HourLoad * Current Hourly Op
Record. OpTime / {LME Total Load Array for the location - LMEAprilLoad
Array for the location)), and round the result to 1 decimal place.
else if {LME Total Optime is greater than 0)
Calculate HIT Calculated Adjusted Value = {{LME CP Total Heat Input - LME CP
April Heat Input) * Current Hourly Op Record. OpTime / {LME Total Optime-LME
April Optime)) + {{LME Total Heat Input Array for the location - LME April Heat
Input Array for the location) * Current Hourly Op Record. OpTime / {LME Total
OpTime Array for the location - LME April OpTime Array for the location)), and round
the result to 1 decimal place.
If {LME Total Load is greater than 0)
If (HourLoad is equal to 0)
Set HIT Calculated Adjusted Value = 0
else
Calculate HIT Calculated Adjusted Value = {LME CP Total Heat Input * Current
Hourly Op Record.HouxLonA * Current Hourly Op Record.OpTime / LME Total Load)
+ {LME Total Heat Input Array for the location * Current Hourly Op Record. HourLoad
* Current Hourly Op Record .0\yT\mc / LME Total Load Array for the location), and
round the result to 1 decimal place.
else if {LME Total Optime is greater than 0)
Calculate HIT Calculated Adjusted Value = {LME CP Total Heat Input * Current Hourly Op
Record. OpTime / LME Total Optime) + {LME Total Heat Input Array for the location *
Current Hourly Op Record. OpTime / LME Total OpTime Array for the location), and round the
result to 1 decimal place.
Otherwise,
Results:
Result
A
Response
You did not report a single, active, valid default record for MHHI in your monitoring
plan.
This check result is obsolete.
Severity
Critical Error Level 1
B
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report HIT Derived Hourly Evaluation (LME)
Environmental Protection Agency
Page 417 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURDHV-38
Check Name: Check Reported Heat Input for LME Unit
Related Former Checks:
Applicability:
Description:
Validation Tables:
Hourly Emissions Tolerances (Cross Check Table)
Specifications:
If (Current DHVRecord. AdjustedHourly Value is null or is less than 0)
Rpt Period HI Reported Accumulator Array for this location = -1
return result A
else if (Current DHV Record. AdixistQdRomXyVdlxiQ is not rounded to one decimal place)
Rpt Period HI Reported Accumulator Array for this location = -1
return result C
else
if (Current Month is not April OR LME Annual == true)
if (Rpt Period HI Reported Accumulator Array for this location is not null)
if (Rpt Period HI Reported Accumulator Array >= 0)
Rpt Period HI Reported Accumulator Array for this location = Rpt Period HI Reported Accumulator
Array for this location + Current DHV Record. A dj u s t ed H o u r l y Va 1 lie
else
Rpt Period HI Reported Accumulator Array for this location = Current DHV Record. Adj ustedHourlyValue
If (HIT Calculated Adjusted Value is not null and Current DHV Record. A dj u s t ed H o u r ly Va 1 lie is not equal to HIT Calculated
Adjusted Value)
If (HIT Calculated Adjusted Value is greater than 1 OR Current DHV Record .k&\\iS{cAHo\.tf\\V'c\\\iC is greater than 1)
Heat Input Tolerance = Lookup Tolerance from Cross-Check Table "Hourly Emissions Tolerances" where
Parameter = "HIT" AND
UOM = "MMBTU"
if (AB S( Current DHV Record. Adj ustedHourly Value - HIT Calculated Adjusted Value) > Heat Input Tolerance)
return result B.
Results:
Result Response Severity
A The AdjustedHourly Value reported in the DHV record for [param] is invalid. The Critical Error Level 1
value must be greater than or equal to 0.
B The AdjustedHourly Value reported in the DHV record for [param] is inconsistent with Critical Error Level 1
the recalculated value.
C You reported [fieldname] in the [type] record for [param] that is not rounded to the Critical Error Level 1
appropriate precision for that parameter.
Environmental Protection Agency
Page 418 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
Usage:
1 Process/Category: Emissions Data Evaluation Report HIT Derived Hourly Evaluation (LME)
Environmental Protection Agency
Page 419 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURDHV-39
Check Name: Calculate S02 Mass for LME Unit
Related Former Checks:
Applicability:
Description:
Specifications:
S02M Calculated Adjusted Value = null
If Current DHVRecord.FuelCode is null,
Rpt Period S02 Mass Calculated Accumulator Array for this location = -1
return result A.
Otherwise,
Locate MonitorDefault record for the hour and location where ParameterCd = "S02R", DefaultPurposeCd = "LM", and FuelCode
is equal to Current DHV Record. FuelCode.
If not found, or if more than one record is found, or if DefaultValue is less than or equal to 0, or DefaultValueUnitsOfMeasure is
not equal to "LBMMBTU".
Rpt Period S02 Mass Calculated Accumulator Array for this location = -1
return result B.
Otherwise,
S02R Default Value = MonitorDefault.DefaultValue
Locate MonitorDefault record for the hour and location where ParameterCd = "S02R", DefaultPurposeCd = "LM",
FuelCode is in LME Fuel Code List, FuelCode is not equal to Current DHV Record. FuelCode, Default Value is greater
than S()2R Default Value, and DefaultValueUnitsOfMeasure is equal to "LBMMBTU".
If found,
Rpt Period S02 Mass Calculated Accumulator Array for this location = -1
return result C.
Otherwise,
If HIT Calculated Adjusted Value is null,
Rpt Period S02 Mass Calculated Accumulator Array for this location = -1
return result D.
else
Calculate S02M Calculated Adjusted Value = HIT Calculated Adjusted Value * S02R Default Value,
and round the result to one decimal place.
if (Rpt Period S02 Mass Calculated Accumulator Array for this location is not null)
if (Rpt Period S02 Mass Calculated Accumulator Array for this location >= 0)
Rpt Period S02 Mass Calculated Accumulator Array for this location = Rpt Period S02
Mass Calculated Accumulator Array for this location + S02M Calculated Adjusted
Value
else
Rpt Period S02 Mass Calculated Accumulator Array for this location = SOI Mass Calculated
Adjusted Value
Environmental Protection Agency
Page 420 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
A
B
C
D
Response
The AdjustedHourly Value in the DHV record for [param] could not be recalculated,
because you did not report a FuelCode in this record.
You have not reported one and only one active Monitor Default record with a valid
ParameterCode and DefaultPurposeCode in your monitoring plan to report the default
emission rate for the fuel. The AdjustedHourly Value in the DHV for [param] could not
be recalculated.
You reported [Fuel] as the FuelCode in the DHV record for [param], but, according to
the Monitor Default records in your monitoring plan, this fuel does not have the highest
default emissions rate of the fuels combusted during the hour. The
AdjustedHourly Value could not be recalculated.
The AdjustedHourly Value in the DHV record for [param] could not be recalculated
because the heat input rate could not be determined for the hour.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Informational Message
Usage:
1
Process/Category: Emissions Data Evaluation Report S02M Derived Hourly Evaluation (LME)
Environmental Protection Agency
Page 421 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURDHV-40
Check Name: Determine Fuels Burned for LME Unit
Related Former Checks:
Applicability:
Description:
Specifications:
LME Fuel Code List = null
If (HIT Calculated Adjusted Value is not null)
Locate all DerivedHourlyValue records for the location and hour where ParameterCode in set {S02M, C02M, NOXM}
For each record found,
Append DerivedHourlyValue. FuelCode to LME Fuel Code List.
if (Current Month is not April OR LME Annual == true)
if (Rpt Period HI Calculated Accumulator Array for this location is not null)
if (Rpt Period HI Calculated Accumulator Array for this location >= 0)
Rpt Period HI Calculated Accumulator Array for this location = Rpt Period HI Calculated Accumulator
Array for this location + HIT Calculated Adjusted Value
else
Rpt Period HI Calculated Accumulator Array for this location = HIT Calculated Adjusted Value
if (Current Month is April)
if (April HI Calculated Accumulator Array for this location is not null)
April HI Calculated Accumulator Array for this location = April HI Calculated Accumulator Array for
this location + HIT Calculated Adjusted Value
else
April HI Calculated Accumulator Array for this location = HIT Calculated Adjusted Value
if (Current Month is not April OR LME Annual == true)
Rpt Period HI Calculated Accumulator Array for this location = -1
return result A
else
Results:
Result Response Severity
A The AdjustedHourly Value in the DHV record for HIT could not be recalculated due to Informational Message
another error listed in this report.
Usage:
1 Process/Category: Emissions Data Evaluation Report HIT Derived Hourly Evaluation (LME)
Environmental Protection Agency
Page 422 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURDHV-41
Check Name: Check Reported S02M for LME Unit
Related Former Checks:
Applicability:
Description:
Validation Tables:
Hourly Emissions Tolerances (Cross Check Table)
Specifications:
If (Current DHVRecord. AdjustedHourly Value is null or is less than 0)
Rpt Period S02 Mass Reported Accumulator Array for this location = -1
return result A
else if (Current DHV Record. AdixistQdRomXyVdlxiQ is not rounded to one decimal place)
Rpt Period S02 Reported Accumulator Array for this location = -1
return result C
else
if (Rpt Period S02 Mass Reported Accumulator Array for this location is not null)
if (Rpt Period S02 Mass Reported Accumulator Array >= 0)
Rpt Period S02 Mass Reported Accumulator Array for this location = Rpt Period S02 Mass Reported
Accumulator Array for this location + Current DHV Record .Adj ustedHourly Value
else
Rpt Period S02 Mass Reported Accumulator Array for this location = Current DHV Record. A dj u s tc d H o u r ly Va 1 lie
If (S02M Calculated Adjusted Value is not null AND Current DHV Record. Adj ustedHourly Value is not equal to S02M
Calculated Adjusted Value)
S02Mass Tolerance = Lookup Tolerance from Cross-Check Table "Hourly Emissions Tolerances" where
Parameter = "S02M" AND
UOM= "LB"
if (AB S (Current DHV Record. A dj u s t ed H o u r ly Va 1 lie - S02M Calculated Adjusted Value) > S02 Mass Tolerance)
return result B
Results:
Result Response Severity
A The AdjustedHourly Value reported in the DHV record for [param] is invalid. The Critical Error Level 1
value must be greater than or equal to 0.
B The AdjustedHourly Value reported in the DHV record for [param] is inconsistent with Critical Error Level 1
the recalculated value.
C You reported [fieldname] in the [type] record for [param] that is not rounded to the Critical Error Level 1
appropriate precision for that parameter.
Usage:
1 Process/Category: Emissions Data Evaluation Report S02M Derived Hourly Evaluation (LME)
Environmental Protection Agency
Page 423 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURDHV-42
Check Name: Calculate C02 Mass for LME Unit
Related Former Checks:
Applicability:
Description:
Specifications:
C02M Calculated Adjusted Value = null
If Current DHVRecord.FuelCode is null,
Rpt Period C02 Mass Calculated Accumulator Array for this location = -1
return result A.
Otherwise,
Locate MonitorDefault record for the hour and location where ParameterCd = "C02R", DefaultPurposeCd = "LM", and FuelCode
is equal to Current DHV Record. FuelCode.
If not found, or if more than one record is found, or if DefaultValue is less than or equal to 0, or DefaultValueUnitsOfMeasure is
not equal to "TNMMBTU".
Rpt Period C02 Mass Calculated Accumulator Array for this location = -1
return result B.
Otherwise,
C02R Default Value = MonitorDefault. Dcfau 11Va 1 lie
Locate MonitorDefault record for the hour and location where ParameterCd = "C02R", DefaultPurposeCd = "LM",
FuelCode is in LME Fuel Code List, FuelCode is not equal to Current DHV Record. FuelCode, Default Value is greater
than C02R Default Value, and DefaultValueUnitsOfMeasure is equal to "TNMMBTU".
If found,
Rpt Period C02 Mass Calculated Accumulator Array for this location = -1
return result C.
Otherwise,
If HIT Calculated Adjusted Value is null,
Rpt Period C02 Mass Calculated Accumulator Array for this location = -1
return result D.
else
Calculate C02M Calculated Adjusted Value = HIT Calculated Adjusted Value * C02R Default Value,
and round the result to one decimal place.
if {Rpt Period C02 Mass Calculated Accumulator Array for this location is not null)
if (Rpt Period C02 Mass Calculated Accumulator Array for this location >= 0)
Rpt Period C02 Mass Calculated Accumulator Array for this location = Rpt Period
C02 Mass Calculated Accumulator Array for this location + C02M Calculated
Adjusted Value
else
Rpt Period C02 Mass Calculated Accumulator Array for this location = CO 2 Mass Calculated
Adjusted Value
Environmental Protection Agency
Page 424 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
A
B
C
D
Usage:
1
Response
The AdjustedHourly Value in the DHV record for [param] could not be recalculated,
because you did not report a FuelCode in this record.
You have not reported one and only one active Monitor Default record with a valid
ParameterCode and DefaultPurposeCode in your monitoring plan to report the default
emission rate for the fuel. The AdjustedHourly Value in the DHV for [param] could not
be recalculated.
You reported [Fuel] as the FuelCode in the DHV record for [param], but, according to
the Monitor Default records in your monitoring plan, this fuel does not have the highest
default emissions rate of the fuels combusted during the hour. The
AdjustedHourly Value could not be recalculated.
The AdjustedHourly Value in the DHV record for [param] could not be recalculated
because the heat input rate could not be determined for the hour.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Informational Message
Process/Category: Emissions Data Evaluation Report C02M Derived Hourly Evaluation (LME)
Environmental Protection Agency
Page 425 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURDHV-43
Check Name:
Check Reported C02M for LME Unit
Related Former Checks:
Applicability:
Description:
Validation Tables:
Hourly Emissions Tolerances (Cross Check Table)
Specifications:
If (Current DHVRecord. AdjustedHourly Value is null or is less than 0)
Rpt Period C02 Mass Reported Accumulator Array for this location = -1
return result A
else if (Current DHV Record. AdjustedHourlyValue is not rounded to one decimal place)
Rpt Period C02 Reported Accumulator Array for this location = -1
return result C
else
if (Rpt Period C02 Mass Reported Accumulator Array for this location is not null)
if (Rpt Period C02 Mass Reported Accumulator Array >= 0)
Rpt Period C02 Mass Reported Accumulator Array for this location = Rpt Period C02 Mass Reported
Accumulator Array for this location + Current DHV Record .Adj ustedHourly Value
Rpt Period C02 Mass Reported Accumulator Array for this location = Current DHV Record. k^uiXcAHovuhV'^uc
If (C02M Calculated Adjusted Value is not null AND Current DHV Record. k&\us{cAHo\.tf\\V'c\\\iC is not equal to C02M
Calculated Adjusted Value)
C02Mass Tolerance = Lookup Tolerance from Cross-Check Table "Hourly Emissions Tolerances" where
Parameter = "C02M" AND
UOM = "TON"
if (ABS (Current DHV Record. A dj u s t cd H o u r ly Va 1 uc - C02M Calculated Adjusted Value) > C02 Mass Tolerance)
else
return result B
Results:
Result
A
Response
The AdjustedHourly Value reported in the DHV record for [param] is invalid. The
value must be greater than or equal to 0.
The AdjustedHourly Value reported in the DHV record for [param] is inconsistent with
the recalculated value.
You reported [fieldname] in the [type] record for [param] that is not rounded to the
appropriate precision for that parameter.
Severity
Critical Error Level 1
B
Critical Error Level 1
C
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report C02M Derived Hourly Evaluation (LME)
Environmental Protection Agency
Page 426 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURDHV-44
Check Name:
Calculate NOX Mass for LME Unit
Related Former Checks:
Applicability:
Description:
Specifications:
NOXM Calculated Adjusted Value = null
UDEFStatus = null.
UDEFExpirationDate = null.
If Current DHVRecord.FuelCode is null,
if {Current Month is not April OR LME Annual == true)
Rpt Period NOx Mass Calculated Accumulator Array for this location = -1
return result A
Default Condition = null
If Current DHV Record.OpcrMmgCon^UonCoAc is null,
Default Condition = "A"
else if Current DHV Record .OpcmUngCondlUonCodc in set {C, U, P, B}
Default Condition = Current DHV Record.0\~>cri\{\ngCo\\&\{\o\\CoAc
If Default Condition is null,
if {Current Month is not April OR LME Annual == true)
Rpt Period NOx Mass Calculated Accumulator Array for this location = -1
return result B
if (Current DHV/?£?6Y>/Y/,OpcFtitingConditionCodc is equal to "U")
Locate MonitorDefault record for the hour and location where ParameterCd = "NORX". DefaultPurposeCd =
"MD", OperatingConditionCode is equal to Default Condition, and FuelCode is equal to CurrentDHV
Record. Fuel Code.
Locate MonitorDefault record for the hour and location where ParameterCd = "NOXR". DefaultPurposeCd =
"LM", OperatingConditionCode is equal to Default Condition, and FuelCode is equal to CurrentDHV
Record. Fuel Code.
If not found, or if more than one record is found, or if DefaultValue is less than or equal to 0, or
DefaultValueUnitsOfMeasure is not equal to "LBMMBTU".
if {Current Month is not April OR LME Annual == true)
Rpt Period NOx Mass Calculated Accumulator Array for this location = -1
return result C
Otherwise,
NOXR Default Value = MonitorDefault.DefaultValue
if {Default Condition is in set { A,C,B,P} AND MonitorDefa u It.Dch\u\{^omccCo Ac == "TEST")
Otherwise,
else
else
Environmental Protection Agency
Page 427 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
if (MonitorDefault. G roup ID is null)
if (Default Condition == "A" or "C")
Locate the latest UnitDefaultTestRecordsByLocationForQAStatus for the location
where FuelCode = Current DHVRecord.FuelCode and EndDate/EndHour is on or
before the CurrentOperatingDate/Hour.
else if {Default Condition == "B")
Locate the latest UnitDefaultTestRecordsByLocationForQAStatus for the location
where FuelCode = Current DHV Record. FuelCode, OperatingConditionCode == "A" or
"B", and EndDate/EndHour is on or before the CurrentOperatingDate/Hour.
else if (Default Condition == "P")
Locate the latest UnitDefaultTestRecordsByLocationForQAStatus for the location
where FuelCode = Current DHV Record. FuelCode, OperatingConditionCode == "A" or
"P", and EndDate/EndHour is on or before the CurrentOperatingDate/Hour.
If not found,
UDEFStatus = 'MISSING"
else
UDEFStatus = "FOUND"
Set UDEFExpiration Date to 5 years after the end of the quarter of the
UnitDefaultTestRecordsByLocationForQAStatusEndDatQ.
Otherwise,
UDEFStatus = "GROUP"
Set UDEFExpiration Date to 5 years after the end of the quarter of the
Man itorDefault. B c g i n D a tc.
if {Current DHV Record. OperatingConditionCode is equal to "U")
Locate MonitorDefault record for the hour and location where ParameterCd = "NORX",
DefaultPurposeCd = "MD", OperatingConditionCode is equal to Default Condition, FuelCode is in LME
Fuel Code List, FuelCode is not equal to Current DHV Record. FuelCode, Default Value is greater than
NOXR Default Value, and DefaultValueUnitsOfMeasure is equal to "LBMMBTU".
Locate MonitorDefault record for the hour and location where ParameterCd = "NOXR",
DefaultPurposeCd = "LM", OperatingConditionCode is equal to Default Condition, FuelCode is in LME
Fuel Code List, FuelCode is not equal to Current DHV Record. FuelCode, Default Value is greater than
NOXR Default Value, and DefaultValueUnitsOfMeasure is equal to "LBMMBTU".
If found,
if {Current Month is not April OR LME Annual == true)
Rpt Period NOx Mass Calculated Accumulator Array for this location = -1
return result D
Otherwise,
If HIT Calculated Adjusted Value is null,
if {Current Month is not April OR LME Annual == true)
Rpt Period NOx Mass Calculated Accumulator Array for this location = -1
Environmental Protection Agency
Page 428 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
return result E
else
Calculate NOXM Calculated Adjusted Value = HIT Calculated Adjusted Value * NOXR Default
Value, and round the result to one decimal place.
if {Current Month is not April OR LMEAnnual == true)
if (Rpt Period NOx Mass Calculated Accumulator Array for this location is not null)
if (Rpt Period NOx Mass Calculated Accumulator Array for this location >= 0)
Rpt Period NOx Mass Calculated Accumulator Array for this location
= Rpt Period NOx Mass Calculated Accumulator Array for this
location + NOXM Calculated Adjusted Value
else
Rpt Period NOx Mass Calculated Accumulator Array for this location = NOx
Mass Calculated Adjusted Value
if {Current Month is April)
if {April NOx Mass Calculated Accumulator Array for this location is not null)
April NOx Mass Calculated Accumulator Array for this location =
April NOx Mass Calculated Accumulator Array for this location +
NOXM Calculated Adjusted Value
else
April NOx Mass Calculated Accumulator Array for this location =
NOXM Calculated Adjusted Value
Results:
Result Response
A The AdjustedHourly Value in the DH V record for [param] could not be recalculated,
because you did not report a FuelCode in this record.
B You reported an invalid OperatingConditionCode in the DHV record for [param]. The
AdjustedHourly Value could not be recalculated.
C You have not reported one and only one active Monitor Default record with a valid
ParameterCode, DefaultPurposeCode, and OperatingConditionCode in your monitoring
plan to report the default emission rate for the fuel. The AdjustedHourly Value in the
DHV for [param] could not be recalculated.
D You reported [Fuel] as the FuelCode in the DHV record for [param], but, according to
the Monitor Default records in your monitoring plan, this fuel does not have the highest
default emissions rate of the fuels combusted during the hour. The
AdjustedHourly Value could not be recalculated.
E The AdjustedHourly Value in the DHV record for [param] could not be recalculated
because the heat input rate could not be determined for the hour.
Usage:
1 Process/Category: Emissions Data Evaluation Report NOXM Derived Hourly Evaluation (LME)
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Informational Message
Environmental Protection Agency
Page 429 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURDHV-45
Check Name: Check Reported NOXM for LME Unit
Related Former Checks:
Applicability:
Description:
Validation Tables:
Hourly Emissions Tolerances (Cross Check Table)
Specifications:
If (Current DHVRecord. AdjustedHourly Value is null or is less than 0)
Rpt Period NOx Mass Reported Accumulator Array for this location = -1
return result A
else if (Current DHV Record is not rounded to one decimal place)
Rpt Period NOx Mass Reported Accumulator Array for this location = -1
return result C
else
if (Current Month is not April OR LME Annual == true)
if (Rpt Period NOx Mass Reported Accumulator Array for this location is not null)
if (Rpt Period NOx Mass Reported Accumulator Array >= 0)
Rpt Period NOx Mass Reported Accumulator Array for this location = Rpt Period NOx Mass Reported
Accumulator Array for this location + Current DHV Record. A dj u s t ed H o u r ly Va 1 lie
else
Rpt Period NOx Mass Reported Accumulator Array for this location = Current DHV
Record Ad) ustedHourly Value
If (NOXM Calculated Adjusted Value is not null AND Current DHV Record. A dj u s t ed H o u r ly Va 1 lie is not equal to NOXM
Calculated Adjusted Value)
NOX Mass Tolerance = Lookup Tolerance from Cross-Check Table "Hourly Emissions Tolerances" where
Parameter = "NOXM" AND
UOM= "LB"
if (AB S( Current DHV Record. Adj ustedHourly Value - NOXM Calculated Adjusted Value) > NOX Mass Tolerance)
return result B
Results:
Result Response Severity
A The AdjustedHourly Value reported in the DHV record for [param] is invalid. The Critical Error Level 1
value must be greater than or equal to 0.
B The AdjustedHourly Value reported in the DHV record for [param] is inconsistent with Critical Error Level 1
the recalculated value.
C You reported [fieldname] in the [type] record for [param] that is not rounded to the Critical Error Level 1
appropriate precision for that parameter.
Usage:
1 Process/Category: Emissions Data Evaluation Report NOXM Derived Hourly Evaluation (LME)
Environmental Protection Agency
Page 430 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURDHV-46
Check Name: Equation Code Consistent with Moisture Basis
Related Former Checks:
Applicability:
Description:
Specifications:
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report S02M Derived Hourly Evaluation (LME)
Environmental Protection Agency
Page 431 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURDHV-47
Check Name: Unit Default Test Expiration Check
Related Former Checks:
Applicability:
Description:
Specifications:
If UDEF Status is not null,
If {UDEFStatus == 'MISSING")
return result A.
else if {UDEF Status == "FOUND")
if {Current Operating Date is after the UDEF Expiration Date)
return result B.
else
Append CurrentDHV .¥ uclCodc to the LME Fuel Array for the location.
else if {UDEF Status == "GROUP")
if {Current Operating Date is after the UDEF Expiration Date)
return result C.
Results:
Result
A
B
C
Response
You did not report an applicable prior LME Unit Default Test for Fuel Code [FUEL],
The applicable prior LME Unit Default Test for Fuel Code [FUEL] has expired. You
need to use a Part 75 default NOx emissions rate until you perform a new
unit-and-fuel-specific default test. You will need to put an end date on your existing
NOXR default records in your monitoring plan, and add a new NOXR default record
based on the Part 75 default value.
Warning: Based on the BeginDate in your NOXR Default record in your monitoring
plan, the LME Unit Default Test(s) that established the default NOx emission rate for
Fuel Code [FUEL] may have expired. Unit Default Tests must be performed every five
years. If your test has expired, you need to use a Part 75 default NOx emissions rate
until you perform a new unit-and-fuel-specific default test. You will need to put an end
date on your existing NOXR default records in your monitoring plan, and add a new
NOXR default record based on the Part 75 default value.
Severity
Critical Error Level 1
Critical Error Level 1
Informational Message
Usage:
1
Process/Category: Emissions Data Evaluation Report NOXM Derived Hourly Evaluation (LME)
Environmental Protection Agency
Page 432 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Category:
Hourly General
Environmental Protection Agency
Page 433 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURGEN-1
Check Name:
Initialize Accumulators for Summary Value Data
Related Former Checks:
Applicability:
Description:
Specifications:
For each location in Monitoring Plan, initialize arrays with size Current Location Count
Rpt Period C02 Mass Reported Accumulator Array for the location = 0
Rpt Period C02 Mass Calculated Accumulator Array for the location =0
Expected Summary Value C02 Array for the location = false
Rpt Period HI Reported Accumulator Array for the location =0
Rpt Period HI Calculated Accumulator Array for the location = 0
Expected Summary Value HI Array for the location = false
Rpt Period NOx Rate Reported Accumulator Array for the location = 0
Rpt Period NOx Rate Calculated Accumulator Array for the location = 0
Rpt Period NOx Rate Hours Accumulator Array for the location = 0
Expected Summary Value NOx Array for the location = false
Rpt Period S02 Mass Reported Accumulator Array for the location = 0
Rpt Period S02 Mass Calculated Accumulator Array for the location = 0
Expected Summary Value S02 Array for the location = false
Rpt Period NOx Mass Reported Accumulator Array for the location = 0
Rpt Period NOx Mass Calculated Accumulator Array for the location = 0
Expected Summary Value NOx Mass Array for the location = false
Rpt Period Op Time Accumulator Array for the location = 0
Rpt Period Op Hours Accumulator Array for the location = 0
Rpt Period Op Days Accumulator Array for the location = 0
Rpt Period Load Accumulator Array for the location = 0
Daily Op Time Accumulator Array for this location = 0
April HI Calculated Accumulator Array for the location = 0
April NOx Mass Calculated Accumulator Array for the location = 0
April Op Time Accumulator Array for the location = 0
April Op Hours Accumulator Array for the location = 0
April Op Days Accumulator Array for the location = 0
LME Total Load Array for the location = 0
LME April Load Array for the location = 0
LME Total Heat Input Array for the location = 0
LME April Heat Input Array for the location = 0
LME Total Op Time Array for the location = 0
LME April Op Time Array for the location = 0
Last Day of Operation Array for the location = null
First Day of Operation = null
First Hour of Operation = null
FLOW System ID Array for the location = null
NOXE System ID Array for the location = null
LME Fuel Array for the location = null
Environmental Protection Agency
Page 434 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Operating Date Array for the location = empty date list
Count the number of unique location + FuelCode in the Hourly Fuel Flow records for the monitoring configuration and reporting period.
Initialize an array with this number of elements:
Fuel Op Hours Accumulator Array for the location and FuelCode = 0
Initialize F2LStatusSystemResultDictionary as a dictionary with both a string key and lookup value
Initialize F2LStatusSystemCheckDictionary as a dictionary with a string key and a data row value
Initialize F2LStatusSystemMissingOpDictionary as a dictionary with both a string key and lookup value
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Summary Value Initialization
Environmental Protection Agency
Page 435 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURGEN-2
Check Name: Reporting Period Details
Related Former Checks:
Applicability:
Description:
Specifications:
Abort Hourly Checks = false
Legacy Data Evaluation = false
LME HI Method = null
LME HI Substitute Data Code = null
Annual Reporting Requirement = false
OS Reporting Requirement = false
LME Annual = false
LME OS = false
Reported Emissions Value = null
Multiple Stack Configuration = false
Ignored Daily Calibration Tests = false
Ignored Daily Interference Tests = false
if ({Current Reporting Period < Current Monitoring Plan . Bcgi nRcpo rt Pcriod) OR
{Current Monitoring Plan Record. EndRcportPcriod is not null AND Current Monitoring Plan Ttecon/.EndReportPeriod <
Current Reporting Period))
Abort Hourly Checks = true
return result A
else
Locate a UnitProgram record for any unit in the configuration where ProgramCode in set {NBP, CAIROS, TRNOXOS, NHNOX,
SIPNOX}, UnitMonitorCertBeginDate is on or before the December 31 of the year of the Current Reporting Period, and the
EndDate is null or is on or after Jan 1 of the year of the Current Reporting Period.
If found,
OS Reporting Requirement = true
Locate all LocationReportingFrequency record for any unit in the configuration where BeginQuarter is on or before the Current
Reporting Period, and the EndQuarter is null or is on or after the Current Reporting Period.
If found, and the ReportingFrequencyCode in all records == "Q",
Annual Reporting Requirement = true
else if found, and the ReportingFrequencyCode in all records == "OS",
If OS Reporting Requirement == false
Abort Hourly Checks = true
return result B
else if the Quarter of the Current Reporting Period is equal to 1 or 4,
Abort Hourly Checks = true
return result C
Otherwise,
Abort Hourly Checks = true
return result B
If {Abort Hourly Checks == false)
If (the associated First ECMPS Reporting Period for the monitoring plan is null)
If Current Reporting Period is on or prior to 2008)
Environmental Protection Agency
Page 436 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Legacy Data Evaluation = true
Else
If Current Reporting Period is prior to the First ECMPS Reporting Period)
Legacy Data Evaluation = true
Locate a Hourly Op Data record for the configuration and reporting period where OperatingTime is greater than 0,
If found,
Reporting Period Operating = true
else,
Reporting Period Operating = false
Locate MonitorMethod record for ANY location in the file where ParameterCode in set {S02M, NOXM, C02M}, MethodCode =
"LME"
BeginDate is on or before the first day of the Current Reporting Period, and the EndDate is null or is on or after the last day of the
Current Reporting Period.
If found,
Locate all MonitorQualification records for all units in the monitoring configuration where the QualificationTypeCode is
equal to "LMEA" or "LMES", BeginDate is on or before the last day of the reporting period, and the EndDate is null or is
on or after December 31 of the year prior to the Current Reporting Period.
If a record with QualificationTypeCode equal to "LMEA" is found,
set LME Annual to true.
If a record with QualificationTypeCode equal to "LMES" is found,
set LME OS to true.
If {LME Annual == true and Annual Reporting Requirement == false)
Abort Hourly Checks = true
return result D
else if (LME OS == true and OS Reporting Requirement == false)
Abort Hourly Checks = true
return result E
else if (LMEAnnual == false and LME OS == false)
Abort Hourly Checks = true
return result F
Otherwise,
Locate MonitorMethod records for all locations in the file where ParameterCode = "HIT", BeginDate is on or
before the first day of the Current Reporting Period, and the EndDate is null or is on or after the last day of the
Current Reporting Period.
If not found for any location,
Abort Hourly Checks = true
return result G
If MethodCode = "MHHI" for all locations,
LME HI Method = "MHHI"
If MethodCode in set {LTFF, CALC, LTFCALC} for all locations,
LME HI Method = "LTFF"
If SubstituteDataCode is equal to "MHHI" for any location,
LME HI Substitute Data Code= "MHHI".
Environmental Protection Agency
Page 437 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Otherwise,
Abort Hourly Checks = true
return result H
If (Abort Hourly Checks == false)
Locate all Unit Program records for all units in the configuration where the UnitMonitorCertBeginDate is on or prior to the Current
Reporting Period and the EndDate is null or is on or after the Current Reporting Period.
If the ProgramCode in all the retrieved Location Program records are only equal to "NBP", "OTC", "NHNOX", or "SIPNOX",
Locate all Unit Operating Status records for all units in the configuration where the Op Status Code is equal to "RET", the
year of the Begin Date is prior to Current Reporting Period, and the End Date is null or is on or after the last day of the
Current Reporting Period.
If found,
return result I
Otherwise,
For each Unit Program record retrieved above where the ProgramCode is not equal to "NBP", "OTC", "NHNOX", or
"SIPNOX",
If Program Code is equal to "CAIROS" or "TRNOXOS" and the Current Reporting Period is in the first or second
quarter,
Locate a Unit Program Exemption record for the unit program where the Exempt Type is equal to "RUE",
the Exemption Begin Date is on or prior to May 1 of the year of the Current Reporting Period, and the
Exemption End Date is null or is on or after the last day of the Current Reporting Period.
Otherwise,
Locate a Unit Program Exemption record for the unit program where the Exempt Type is equal to "RUE",
the Exemption Begin Date is on or prior to the first day of the Current Reporting Period, and the
Exemption End Date is null or is on or after the last day of the Current Reporting Period.
If a Unit Program Exemption record was found for all unit programs,
return result I
Environmental Protection Agency
Page 438 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
A
B
C
D
G
H
I
Usage:
1
Response Severity
The locations in the file do not represent a valid monitoring configuration during the Fatal
reporting period. The file will not be evaluated.
The active Reporting Frequency records for this configuration are missing or invalid. Fatal
The file will not be evaluated. Please contact ECMPS technical support for assistance
with this matter.
According to the Reporting Frequency records, this monitoring configuration is an Fatal
ozone-season-only reporter, however the reporting period is not within the ozone
season. The file will not be evaluated.
You have reported an LME Annual Qualification record in your monitoring plan, but, Fatal
according to the Reporting Frequency records, this configuration is not an annual
reporter. The file will not be evaluated.
You have reported an LME Ozone Season Qualification record in your monitoring plan, Fatal
but, according to the Unit Program records, this configuration does not report ozone
season totals. The file will not be evaluated.
You have reported an LME method in your monitoring plan for one or more units in Fatal
this configuration, but you have not reported an LME qualification record. The file will
not be evaluated.
You did not report an active heat input method for one or more locations in the file. Fatal
The file will not be evaluated.
The active heat input methods reported for the locations in the file are inconsistent. The Fatal
file will not be evaluated.
This file contains at least one unit that is retired. Please contact EPA if you believe that Critical Error Level 2
all units in this configuration should report emissions data during this reporting period.
Process/Category: Emissions Data Evaluation Report Summary Value Initialization
Environmental Protection Agency
Page 439 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURGEN-3
Check Name:
Related Former Checks:
Calculate Total Load for LME Configuration for Reporting Period
Applicability:
Description:
Specifications:
LME Total Load = 0
LME April Load = 0
LME CP Total Heat Input = 0
LME CP April Heat Input = 0
LME Total Optime = 0
LME April Optime = 0
If {LME HI Method is not null)
If {LME HI Method == "MHHI")
Locate an LTFF record for any location in the monitoring configuration during the reporting period.
If found,
set Abort Hourly Checks to true, and return result A.
else
For each Hourly Op Data record for every unit in the monitoring configuration.
If Hourly Op Data OpTime is not equal to 0 or Hourly Op Data.HourLoad is not null,
If Hourly Op Data HourLoad is greater than or equal to 0 and Hourly Op Data OpTime is between 0 and
1 (inclusive),
Locate the DerivedHourlyValue record for the unit and the hour where ParameterCode is equal to
If found, AND DerivedHourlyValue.MODCCode is null,
Add HourLoad * OpTime to LME Total Load Array for the location
Add HourLoad * OpTime to LME Total Load.
Add OpTime to LME Total OpTime Array for the location
Add OpTime to LME Total Optime.
If the month of Hourly Op Data. Date is "April" AND LME OS is equal to true ,
Add HourLoad * OpTime to LME April Load Array for the location
Add HourLoad * OpTime to LME April Load.
Add OpTime to LME April OpTime Array for the location
Add OpTime to LME April Optime.
If not found, AND Hourly Op /Jafa. HourLoad is greater than 0,
set LME Total Load to -1.
exit for.
Otherwise,
set LME Total Load to -1.
exit for.
If LME OS is equal to true and the reporting period is the second quarter,
Locate an LTFF record for any location in the monitoring configuration during the reporting period where the
'HIT".
Environmental Protection Agency
Page 440 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
FuelFlowPeriodCode is equal to "A".
If found, AND LME April Load is equal to 0 and LME April Optime is equal to 0,
set Abort Hourly Checks to true, and return result C.
else if not found AND {LME April Load is greater than 0 or LME April Optime is greater than 1),
return result F.
Locate an LTFF record for any location in the monitoring configuration during the reporting period where
the FuelFlowPeriodCode is equal to "MJ".
If found,
If (LME Total Load - LME April Load) is equal to 0 and (LME Total Optime - LME April
Optime) is equal to 0,
set Abort Hourly Checks to true, and return result E.
else
If (LME Total Load - LME April Load) is greater than 0 or (LME Total Optime - LME April
Optime) is greater than 1,
return result G.
Locate an LTFF record for any location in the monitoring configuration during the reporting period.
If found,
If LME Total Load is equal to 0 and LME Total Optime is equal to 0,
set Abort Hourly Checks to true, and return result B.
else
If LME Total Load is greater than 0 or LME Total Optime is greater than 1,
return result D.
else
else
Results:
Result
A
Response
You have reported MHHI as the heat input method for this configuration, but you have
reported a long-term fuel flow record.
You have reported a long-term fuel flow record for this reporting period, but the sum of
the load and operating time values in the hourly records (where MHHIIndicator is not
equal to 1) are equal to 0.
You have reported a long-term fuel flow record for April, but the sum of the load and
operating time values in the hourly records (where MHHIIndicator is not equal to 1) are
equal to 0.
You have reported LTFF as the heat input method for this configuration, but you have
not reported a long-term fuel flow record for this reporting period.
You have reported a long-term fuel flow record for May and June, but the sum of the
load and operating time values in the hourly records (where MHHIIndicator is not equal
to 1) are equal to 0.
You have reported LTFF as the heat input method for this ozone-season reporting
configuration, but you have not reported a long-term fuel flow record for April.
You have reported LTFF as the heat input method for this ozone-season reporting
configuration, but you have not reported a long-term fuel flow record for May/June.
Severity
Fatal
B
Fatal
C
Fatal
D
Critical Error Level 1
E
Fatal
F
Critical Error Level 1
G
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Summary Value Initialization
Environmental Protection Agency
Page 441 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURGEN-7
Check Name: Validate LME Eligibility
Related Former Checks:
Applicability:
Description:
Specifications:
If (LME HI Method is not null)
Set LME Exceeding Parameter to null.
Set Final LME Year to false.
For each unit in the monitoring configuration:
If {LMEAnnual == true)
Locate the latest MonitorQualification record where location is the unit being evaluated, the
QualificationTypeCode is equal to "LMEA", BeginDate is on or before the first day of the Current Reporting
Period, and the EndDate is null or is on or after December 31 of the year prior to the Current Reporting Period.
If (not found)
return result A.
If (found and the BeginDate of the retrieved qualification record is prior to the Current Reporting Period Year)
For each year from three years prior to the Current Reporting Period Year until the year prior to the
Current Reporting Year:
Set Annual NOx to 0.
Set Annual S02 to 0.
For quarter 1 until quarter 4:
Locate an Op Supp Data record for the location and quarter/year being checked where
the OpTypeCode = "NOXM".
If (found)
add OpValue to Annual NOx.
Locate an Op Supp Data record for the location and quarter/year being checked where
the OpTypeCode = "S02M".
If (found)
add OpValue to Annual S02.
If (the year being evaluated is the year prior to the Current Reporting Period Year)
If (AnnualNOxis greater than 100 or AnnualS02 is greater than 25)
set Final LME Year to true.
Else
If (AnnualNOxis greater than 100)
append "Annual NOx" to LME Exceeding Parameter.
If (Annual S02 is greater than 25)
append "Annual S02" to LME Exceeding Parameter.
Environmental Protection Agency
Page 442 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
If (LME OS == true)
Locate the latest MonitorQualification record where the location is the unit being evaluated,
QualificationTypeCode is equal to "LMES", BeginDate is on or before the later of the first day of the Current
Reporting Period and May 1 of the year of the Current Reporting Period, and the EndDate is null or is on or after
December 31 of the year prior to the Current Reporting Period.
If (not found)
return result B.
If (found and the BeginDate of the retrieved qualification record is prior to the Current Reporting Period Year)
For each year from three years prior to the Current Reporting Period Year until the year prior to the
Current Reporting Period Year.
Set OS NOx to 0.
Locate an Op Supp Data record for the location and quarter 2 of the year being checked where
the OpTypeCode = "NOXMOS".
If found,
add OpValue to OS NOx.
Locate an Op Supp Data record for the location and quarter 3 of the year being checked where
the OpTypeCode = "NOXM".
If found,
add OpValue to OS NOx.
If (the year being evaluated is the year prior to the Current Reporting Period Year)
If (OS NOx is greater than 50)
set Final LME Year to true.
Else
If (OS NOx is greater than 50)
append "Ozone Season NOx" to LME Exceeding Parameter.
if (LME Exceeding Parameter is not null)
return result C.
else if (Final LME Year == true)
return result D.
Results:
Result
A
Response
You have reported an active LME A qualification record for this configuration in your
monitoring plan, but you have not reported an active LMEA qualification record for at
least one unit in the configuration.
You have reported an active LMES qualification record for this configuration in your
monitoring plan, but you have not reported an active LMES qualification record for at
least one unit in the configuration.
You have reported that this configuration has an active LME qualification, but this
configuration is no longer eligible to qualify for an LME methodology, because at least
one unit in the configuration has exceeded the eligibility limit for [param] in a prior
year.
The emissions from at least one unit in this configuration exceeded the applicable
number of tons necessary to qualify as an LME unit in the previous reporting year.
According to Part 75.19(b), you must install the appropriate monitoring systems by
December 31 of this reporting year.
Severity
Fatal
B
Fatal
C
Critical Error Level 2
D
Informational Message
Environmental Protection Agency
Page 443 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
Usage:
1 Process/Category: Emissions Data Evaluation Report Summary Value Initialization
Environmental Protection Agency
Page 444 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURGEN-8
Check Name:
Monitor Plan Evaluation Check
Related Former Checks:
Applicability:
Description:
Specifications:
Set MpSuccessfulfyEvaluated = false.
If the SeverityLevelCd of the monitoring plan record for this configuration is equal to "CRIT1" or "FATAL",
return result A.
Otherwise,
If the NeedsEvalFlag and MustSubmitFlag of the monitoring plan record for this configuration are equal to "Y",
return result B.
Otherwise,
Set MpSuccessfulfyEvaluated = true.
Results:
Result
A
Response
The Monitoring Plan associated with this quarterly emissions file has critical errors.
You must correct the Monitoring Plan for this monitoring configuration in order to
submit this emissions file to be loaded on EPA's host system.
The Monitoring Plan associated with this quarterly emissions file has not been
evaluated. You must evaluate the Monitoring Plan for this monitoring configuration in
order to complete the evaluation of this emissions file.
Severity
Critical Error Level 1
B
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Summary Value Initialization
Environmental Protection Agency
Page 445 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURGEN-9
Check Name: QA/Cert Test Evaluation Check
Related Former Checks:
Applicability:
Description:
Specifications:
Locate any QA/Cert Test record for the monitoring configuration where the EndDate is on or before the last day of the Current Reporting
Period, MustSubmitFlag is equal to 'Y' or CanSubmitFlag and UpdatedStatusFlag are equal to "Y", and the SeverityCd is equal to "CRIT1"
or "FATAL".
If found,
return result A.
Otherwise,
Locate any QA/Cert Test record for the monitoring configuration where the EndDate is on or before the last day of the Current
Reporting Period, MustSubmitFlag is equal to Y' or CanSubmitFlag and UpdatedStatusFlag are equal to "Y", and the
NeedsEvalFlag are equal to "Y".
If found,
return result B.
Otherwise,
Locate any QA Supp Data record for the monitoring configuration without any associated Test Summary record where the
EndDate is on or before the last day of the Current Reporting Period and MustSubmitFlag is equal to Y'.
If found,
return result C.
Results:
Result
A
B
C
Response
At least one QA/certification test associated with this monitoring configuration has
critical errors. You must correct all prior or concurrent QA/certification tests in order
to submit this quarterly emissions file to be loaded on EPA's host system.
At least one QA/certification test associated with this monitoring configuration has not
been evaluated. You must evaluate all prior or concurrent QA/certification tests in
order to complete the evaluation of this quarterly emissions file.
The emissions quarterly reported cannot be submitted, because EPA has required the
resubmission of a QA/certification test that is not present in the Client Tool. Please
review the Submission Access report for more information about what needs to be
submitted.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1
Process/Category: Emissions Data Evaluation Report Summary Value Initialization
Environmental Protection Agency
Page 446 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURGEN-10
Check Name:
QA/Cert Event Evaluation Check
Related Former Checks:
Applicability:
Description:
Specifications:
Locate any QA/Certification Event record for the monitoring configuration where the QACertEventDate is on or before the last day of the
Current Reporting Period, the MustSubmitFlag is equal to "Y", and the SeverityCd is equal to "CRIT1" or "FATAL".
If found,
return result A.
Otherwise,
Locate any QA/Certification Event record for the monitoring configuration where the QACertEventDate is on or before the last day
of the Current Reporting Period and the MustSubmitFlag and NeedsEvalFlag are equal to "Y".
If found,
return result B.
Results:
Result
A
Response
At least one QA/certification event associated with this monitoring configuration has
critical errors. You must correct all prior or concurrent QA/certification events in order
to submit this quarterly emissions file to be loaded on EPA's host system.
At least one QA/certification event associated with this monitoring configuration has
not been evaluated. You must evaluate all prior or concurrent QA/certification event in
order to complete the evaluation of this quarterly emissions file.
Severity
Critical Error Level 1
B
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Summary Value Initialization
Environmental Protection Agency
Page 447 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURGEN-11
Check Name:
Test Extension/Exemption Evaluation Check
Related Former Checks:
Applicability:
Description:
Specifications:
Locate any Test Extension/Exemption record for the monitoring configuration where the ReportingPeriod is on or before the Current
Reporting Period, the MustSubmitFlag is equal to "Y", and the SeverityCd is equal to "CRIT1" or "FATAL".
If found,
return result A.
Otherwise,
Locate any Test Extension/Exemption record for the monitoring configuration where the ReportingPeriod is on or before the
Current Reporting Period and the MustSubmitFlag and NeedsEvalFlag are equal to "Y".
If found,
return result B.
Results:
Result
A
Response
At least one test extension/exemption associated with this monitoring configuration has
critical errors. You must correct all prior or concurrent test extension/exemption
records in order to submit this quarterly emissions file to be loaded on EPA's host
system.
At least one test extension/exemption associated with this monitoring configuration has
not been evaluated. You must evaluate all prior or concurrent test extension/exemption
records in order to complete the evaluation of this quarterly emissions file.
Severity
Critical Error Level 1
B
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Summary Value Initialization
Environmental Protection Agency
Page 448 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURGEN-12
Check Name: Prior Emissions File Evaluation Check
Related Former Checks:
Applicability:
Description:
Specifications:
Locate any Emissions File for any location in the current monitoring configuration where the ReportingPeriod is prior to the Current
Reporting Period, and either the Submission Availability Code = 'CRITERR' or (CANSUBMIT = 'Y' and SeverityCd is equal to "CRIT1"
or "FATAL").
If found,
return result A.
Otherwise,
Locate any Emissions File for any location in the current monitoring configuration where CAN SUBMIT = 'Y', the
ReportingPeriod is prior to the Current Reporting Period, and the NeedsEvalFlag is equal to "Y".
If found,
return result B.
If not found,
Locate any Emissions File for any location in the current monitoring configuration where the ReportingPeriod is prior to
the Current Reporting Period, and either the Submission Availability Code = 'NOTSUB' or (CAN SUBMIT = 'Y' and
UpdatedStatusFlag = 'NOD ATA1).
If found,
return result C.
Results:
Result
B
C
Response
At least one prior quarterly emissions file for at least one location in this monitoring
configuration has critical errors. You must correct all prior quarterly emissions files in
order to submit this quarterly emissions file to be loaded on EPA's host system.
At least one prior quarterly emissions file for at least one location in this monitoring
configuration has not been evaluated. You must evaluate all prior quarterly emissions
files in order to complete the evaluation for this quarterly emissions file.
At least one prior quarterly emissions file for at least one location in this monitoring
configuration has not been submitted and has been authorized for resubmission. You
must submit all prior quarterly emissions files in order to submit this quarterly
emissions file to be loaded on EPA's host system.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1
Process/Category: Emissions Data Evaluation Report Summary Value Initialization
Environmental Protection Agency
Page 449 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURGEN-13
Check Name:
Determine If File Can Be Submitted
Related Former Checks:
Applicability:
Description:
Specifications:
Locate the Emission Submission Access record for the configuration and reporting period.
If not found, or the Submission Availability Code is null,
return result A.
else if the Submission Availability Code is not equal to "GRANTED" or "REQUIRE",
return result B.
Results:
Result
A
Response
The emissions quarterly report cannot be submitted, either because the EPA has not yet
opened the submission window, you have not logged into the EPA host system, or you
are no longer a representative or agent for this facility. If you are a representative or
agent for this facility, when EPA opens the submission window you should log in to the
EPA host system to receive automatic permission to submit. You will then need to
reevaluate this file prior to submitting.
The emissions quarterly report cannot be resubmitted until you contact the EPA for
permission. After the EPA grants permission, you will need to log in to the EPA host
system to retrieve the permission record. You will then need to reevaluate this file prior
to submitting.
Severity
Informational Message
B
Informational Message
Usage:
1 Process/Category: Emissions Data Evaluation Report Summary Value Initialization
Environmental Protection Agency
Page 450 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURGEN-14
Check Name: Ignored Offline Daily Calibration Check
Related Former Checks:
Applicability:
Description:
Specifications:
If (Ignored Daily Calibration Tests == true)
set Ignored Daily Calibration Tests to false
return result A.
Results:
Result Response Severity
A You reported one or more daily calibration tests that will not fulfill your daily Informational Message
calibration testing requirement, because these tests were performed while the unit was
not operating and you have not reported a prior online-offline calibration
demonstration. These tests have been assigned a CalculatedTestResult of "IGNORED",
and they can be viewed on the Daily Calibration tab of the View Detailed Emissions
Screen. If you intend to use offline tests to fulfill your daily calibration testing
requirement, you must conduct an online-offline calibration demonstration.
Usage:
1 Process/Category: Emissions Data Evaluation Report Summary Value Evaluation
Environmental Protection Agency
Page 451 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURGEN-15
Check Name: Expiring Test Check
Related Former Checks:
Applicability:
Description:
Specifications:
Set Expired Systems and Expiring Systems to null.
Set Expiration Text to "have expired"
If FLOW System ID Array for the location is not null,
For each SystemID in the FLOW System ID Array for the location:
Locate the latest RATATestRecordsByLocationForQAStatus for the location where the SystemID is equal to the
SystemID being checked and the number of operating levels the OpLevelCodeList is equal to 3,
If found,
If RA TA TestRecordsBy Location ForOAStatus.TcstRcasonCodc equal to "INITIAL" then
Locate the latest QACertEventsForEMEvaluation where SystemID is equal to the SystemID being
checked and QACertEventCode equal to "305"
If QACertEventforEMEvaluation.TestCompletionDate is after the
RA TA TestRecordsByLocationForOAStatus.EndDalc
Set ExpirationDate to five years after the end of the quarter of the
OA CertE ventforEME v«/« £>>«. Te s t C o m p 1 e t i o n D a t e
Else
Set ExpirationDate to five years after the end of the quarter of the
RA TA TestRecordsByLocationForQAStatusEndDate
Else
Set ExpirationDate to five years after the end of the quarter of the
RA TA TestRecords By Location ForOAStatus.EndDi\{c.
If ExpirationDate is prior to the current calendar date,
Append the Systemldentifier being checked to Expired Systems.
else if ExpirationDate is on or before the last day of the Current Reporting Period,
Set Expiration Text to "will be expiring at the end of the reporting period".
Append the Systemldenitifier being checked to Expired Systems.
else if ExpirationDate is on or before the last day of the quarter following the Current Reporting Period,
Append the Systemldentifier being checked to Expiring Systems.
If both Expired Systems and Expiring Systems are not null,
return result A
else if Expired Systems is not null,
return result B
else if Expiring Systems is not null,
return result C
else if NOXE System ID Array for the location is not null,
For each SystemID in the NOXE System ID Array for the location:
Locate the latest AppendixETestRecordsByLocationForQAStatus for the location where the SystemID is equal to the
SystemID being checked,
Environmental Protection Agency
Page 452 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
If found,
Set ExpirationDate to five years after the end of the quarter of the
AppendixETestRecordsByLocationForQAStatusEndDats.
If ExpirationDate is prior to the current calendar date,
Append the Systemldentifier being checked to Expired Systems.
else if ExpirationDate is on or before the last day of the Current Reporting Period,
Set Expiration Text to "will be expiring at the end of the reporting period".
Append the Systemldentifier being checked to Expired Systems.
else if ExpirationDate is on or before the last day of the quarter following the Current Reporting Period,
Append the Systemldentifier being checked to Expiring Systems.
If both Expired Systems and Expiring Systems are not null,
return result D
else if Expired Systems is not null,
return result E
else if Expiring Systems is not null,
return result F
else if LME Fuel Array for the location is not null,
For each FuelCode in the LME Fuel Array for the location:
Locate the latest UnitDefaultTestRecordsByLocationForQAStatus for the location where the FuelCode is equal to the
FuelCode being checked,
If found,
Set ExpirationDate to five years after the end of the quarter of the
UnitDefaultTestRecordsBy Location ForQAStatus.EndDi\{c.
If ExpirationDate is prior to the current calendar date,
Append the FuelCode being checked to Expired Systems.
else if ExpirationDate is on or before the last day of the Current Reporting Period,
Set Expiration Text to "will be expiring at the end of the reporting period".
Append the FuelCode being checked to Expired Systems.
else if ExpirationDate is on or before the last day of the quarter following the Current Reporting Period,
Append the FuelCode being checked to Expiring Systems.
If both Expired Systems and Expiring Systems are not null,
return result G
else if Expired Systems is not null,
return result H
else if Expiring Systems is not null,
return result I
Environmental Protection Agency
Page 453 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
B
C
D
H
Usage:
1
Response
Warning: The three-level RATA conducted for each of the following monitoring
systems [TEXT]: System ID(s) [EXPIRED]. Except for a 720 operating-hour grace
period extension, you will need monitor stack flow with another FLOW system or
report substitute data until you perform another three-level RATA. In addition, the
three-level RATA conducted for each of the following monitoring systems will expire
at the end of the next reporting period: System ID(s) [EXPIRING]. Three-level RATAs
expire after five years.
Warning: The three-level RATA conducted for each of the following monitoring
systems [TEXT]: System ID(s) [EXPIRED]. Except for a 720 operating-hour grace
period extension, you will need monitor stack flow with another FLOW system or
report substitute data until you perform another three-level RATA. Three-level RATAs
expire after five years.
Prior Notice: The three-level RATA conducted for each of the following monitoring
systems will expire at the end of the next reporting period: System ID(s) [EXPIRING].
Three-level RATAs expire after five years.
Warning: The Appendix E test conducted to determine the NOx correlation curve for
each of the following monitoring systems [TEXT]: System ID(s) [EXPIRED], In
subsequent reporting periods, you will need report substitute data until you perform
another Appendix E test. In addition, the Appendix E test conducted for each of the
following monitoring systems will expire at the end of the next reporting period:
System ID(s) [EXPIRING]. Appendix E tests expire after five years.
Warning: The Appendix E test conducted to determine the NOx correlation curve for
each of the following monitoring systems [TEXT]: System ID(s) [EXPIRED], In
subsequent reporting periods, you will need report substitute data until you perform
another Appendix E test. Appendix E tests expire after five years.
Prior Notice: The Appendix E test conducted to determine the NOx correlation curve
for each of the following monitoring systems will expire at the end of the next reporting
period: System ID(s) [EXPIRING]. Appendix E tests expire after five years.
Warning: The LME Unit Default Test conducted to determine the default NOx
emission rate for each of the following fuels [TEXT]: Fuel Code(s) [EXPIRED], In
subsequent reporting periods, you will need report substitute data until you perform
another Unit Default Test. In addition, the Unit Default Test conducted for each of the
following fuels will expire at the end of the next reporting period: Fuel Code(s)
[EXPIRING]. LME Unit Default Tests expire after five years.
Warning: The LME Unit Default Test conducted to determine the default NOx
emission rate for each of the following fuels [TEXT]: Fuel Code(s) [EXPIRED], In
subsequent reporting periods, you will need report substitute data until you perform
another Unit Default Test. LME Unit Default Tests expire after five years.
Prior Notice: The LME Unit Default Test conducted to determine the default NOx
emission rate for each of the following fuels will expire at the end of the next reporting
period: Fuel Code(s) [EXPIRING]. LME Unit Default Tests expire after five years.
Process/Category: Emissions Data Evaluation Report Summary Value Evaluation
Severity
Informational Message
Informational Message
Informational Message
Informational Message
Informational Message
Informational Message
Informational Message
Informational Message
Informational Message
Environmental Protection Agency
Page 454 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURGEN-16
Check Name: Ignored Offline Daily Interference Check
Related Former Checks:
Applicability:
Description:
Specifications:
If (Ignored Daily Interference Tests == true)
return result A.
Results:
Result Response Severity
A You reported one or more daily interference checks that will not fulfill your daily Informational Message
testing requirement for your stack flow monitors, because these tests were performed
while the unit was not operating. These tests have been assigned a
CalculatedTestResultof "IGNORED". They can be viewed on the Other Daily Tests
tab of the View Detailed Emissions Screen.
Usage:
1 Process/Category: Emissions Data Evaluation Report Summary Value Evaluation
Environmental Protection Agency
Page 455 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURGEN-17
Check Name: Missing Peaking or Gas Fired Qualification Percent Check
Related Former Checks:
Applicability:
Description:
Specifications:
If Mp Successfully Evaluated equals true,
Set Qualification Percent Missing List = null.
For each QualificationRecord record in MpQualificationRecords where QualificationTypeCode is equal to "PK", "SK" or "GF",
BeginDate is on or before Current Reporting Period End Hour, and EndDate is null or or is on or after Current Reporting Period
Begin Hour :
Locate the record in MpQualificationPercentRecords where MonitorQualificationld is equal to
QualificationRecord.MomtorQuaiificationld, and QualificationDataYear is equal to CurrentReportingPeriodYear.
If not found,
Add MpQualificationRecords. Location I d to Qualification Percent Missing List.
If Qualification Percent Missing List is not null,
return result A.
Results:
Result Response Severity
A You did not report a current year peaking qualification percent record. Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Summary Value Initialization
Environmental Protection Agency
Page 456 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURGEN-18
Check Name:
Validate Unit Fuel
Related Former Checks:
Applicability:
Description:
Specifications:
If Quarter of the Current Reporting Period is equal to I,
For each unit in MonitoringPlanLocationRecords
Locate all Facility Unit Fuel Records for the unit where :
1) Indicator Code is equal to "P"
2) BeginDate is prior to the end date of Current Reporting Period.
3) EndDate is null OR is after the begin date of Current Reporting Period.
If found,
Set Sum of Op Hours to 0
Locate all Facility Operating Supp Data Records for the unit where:
a) The calendar year is the year prior to the calendar year of Current Reporting Period.
b) Parameter Code is equal to "OPHOURS".
c) Fuel Code is equal to NULL.
For each located record
Increment Sum of Op Hours by Facility Operating Supp Data Records. O p V a 1 lie
If Sum of Op Hours > 168
Set Sum of Op Hours by Fuel to null
Locate all Facility Operating Supp Data Records for the unit where:
a) The calendar year is the year prior to the calendar year of Current Reporting Period.
b) Parameter Code is equal to "OPHOURS".
c) Fuel Code is NOT equal to NULL.
For each located record
Increment Sum of Op Hours by Fuel for Facility Operating Supp Data Records.¥uc\Codc. by
Facility Operating Supp Data Records. O p Va 1 lie
For each FuelCode in Sum of Op Hours by Fuel
If {Sum of Op Hours by Fuel / Sum of Op Hours is greater than or equal to 0.60)
For each located Facility Unit Fuel Records record
If Facility Unit Fuel Records. FuclCodc is not equal to the FuelCode for Sum of
Op Hours by Fuel
return A
Environmental Protection Agency
Page 457 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result Response Severity
A The current active primary fuel type defined in the monitoring plan is inconsistent with Informational Message
the prior year operating hours by fuel type. Please update the primary fuel type in the
monitoring plan to match the prior year predominant fuel type by operating hours.
Usage:
1 Process/Category: Emissions Data Evaluation Report Summary Value Initialization
Environmental Protection Agency
Page 458 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURGEN-19
Check Name:
Initialize Sorbent Trap Check Parameters
Related Former Checks:
Applicability:
Description:
Specifications:
Set MatsSorbentTrapEvaluationNeeded to false.
Initialize MatsSorbentTrapDictionary to an empty dictionary.
Initialize MatsSamplingTrainDictionary to an empty dictionary.
Initialize MatsSorbentTrapListByLocationArray with the number of elements equal to CurrentLocationCount.
For each record in MatsSorbentTrapSupplementalDataRecords
II Note that MatsSorbentTrapSupplementalDataRecords only contains records for which the begin date of the reporting period
// is between the BeginDate and EndDate of the Sorbent Trap Supplemental Data record.
Set SorbentTrapInformation record with:
1) SorbentTrapValidExists set to false .
2) SorbentTrapForQuarterBoarder set to true.
3) SorbentTrapBeginDateHour set to BeginDateHour for the current record in MatsSorbentTrapSupplementalDataRecords
4) SorbentTrapEndDateHour set to EndDateHour for the current record in MatsSorbentTrapSupplementalDataRecords
5) SamplingTrainProblemComponentExists set to false.
6) SamplingTrainDictionary set to an empty dictionary.
7) OperatingDateList set to an empty list of dates.
Set MatsSorbentTrapDictionary entry to SorbentTrapInformation, where key is equal to Trapld for the current record in
MatsSorbentTrapSupplementalDataRecords.
If Count of records in MatsSorbentTrapRecords is greater than 0,
Set MatsSorbentTrapEvaluationNeeded to true.
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Summary Value Initialization
Environmental Protection Agency
Page 459 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURGEN-20
Check Name: Initialize Weekly System Integrity Test Dictionary
Related Former Checks:
Applicability:
Description:
Specifications:
Initialize WsiTestDictionary with a string key for Componentld, and an entry with the following fields:
1) MostRecentTestRecord to hold a CurrentWeeklySystemlntegrify record.
2) LastEvaluatedTestRecord to hold a CurrentWeeklySystemlntegrify record.
3) OperatingDateList to hold a date list.
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Summary Value Initialization
Environmental Protection Agency
Page 460 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURGEN-21
Check Name: Initialize General Lists
Related Former Checks:
Applicability:
Description:
Validation Tables:
Test Result Code (Lookup Table)
Specifications:
Append each TestResultCodeLookupTable.TestResultCode to TestResultCodeList delimited by a comma.
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Summary Value Initialization
Environmental Protection Agency
Page 461 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURGEN-4
Check Name:
Emission Comment Reporting Period Valid
Related Former Checks:
Applicability:
Description:
Specifications:
For a Emission Comment record:
If ReportingPeriod is null,
return result A.
Results:
Result Response Severity
A You did not provide [fieldname], which is required for [key]. Fatal
Usage:
1 Process/Category: Emissions Data Entry Screen Evaluation Emission Comments Evaluation
Environmental Protection Agency
Page 462 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURGEN-5
Check Name:
Submission Comment Valid
Related Former Checks:
Applicability:
Description:
Specifications:
For the Emission Comment record:
If SubmissionComment is null,
return result A.
Results:
Result Response Severity
A You did not provide [fieldname], which is required for [key]. Fatal
Usage:
1 Process/Category: Emissions Data Entry Screen Evaluation Emission Comments Evaluation
Environmental Protection Agency
Page 463 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURGEN-6
Check Name:
Duplicate Emission Comment Records
Related Former Checks:
Applicability:
Description:
Specifications:
For a Emission Comment record:
Locate another EmissionComment record for the monitoring plan with a ReportingPeriod equal to the ReportingPeriod in the
current record.
If found,
return result A.
Results:
Result
A
Response
Another [recordtype] record already exists with the same [fieldnames].
Severity
Fatal
Usage:
1 Process/Category: Emissions Data Entry Screen Evaluation Emission Comments Evaluation
Environmental Protection Agency
Page 464 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Category:
Hourly Monitor Data
Environmental Protection Agency
Page 465 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURMHV-1
Check Name: Initialize S02C Hourly Monitor Data
Related Former Checks:
Applicability:
Description:
Specifications:
Current MHV Parameter = "S02C"
S02C Calculated Adjusted Value = null
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report S02 Monitor Hourly Evaluation
Environmental Protection Agency
Page 466 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURMHV-2
Check Name: Initialize H20 Hourly Monitor Data
Related Former Checks:
Applicability:
Description:
Specifications:
Current MHV Parameter = "H20"
H20 MHV Calculated Adjusted Value = null
Results:
Result Response
Usage:
1 Process/Category: Emissions Data Evaluation Report
Severity
H20 Monitor Hourly Evaluation
Environmental Protection Agency
Page 467 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURMHV-3
Check Name: Initialize NOXC Hourly Monitor Data
Related Former Checks:
Applicability:
Description:
Specifications:
Current MHV Parameter = "NOXC"
NOXC Calculated Adjusted Value = null
Results:
Result Response
Usage:
1 Process/Category: Emissions Data Evaluation Report
Severity
NOx Concentration Monitor Hourly Evaluation
Environmental Protection Agency
Page 468 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURMHV-4
Check Name: Initialize Flow Hourly Monitor Data
Related Former Checks:
Applicability:
Description:
Specifications:
Current MHV Parameter = "FLOW"
FLOW Calculated Adjusted Value = null
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report FLOW Monitor Hourly Evaluation
Environmental Protection Agency
Page 469 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURMHV-5
Check Name: Initialize C02C Hourly Monitor Data
Related Former Checks:
Applicability:
Description:
Specifications:
Current MHV Parameter = "C02C"
C02C MHV Calculated Adjusted Value = null
Results:
Result Response
Usage:
1 Process/Category: Emissions Data Evaluation Report
Severity
C02 Concentration Monitor Hourly Evaluation
Environmental Protection Agency
Page 470 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURMHV-6
Check Name: Initialize 02 Dry Hourly Monitor Data
Related Former Checks:
Applicability:
Description:
Specifications:
Current MHV Parameter = "02D"
02 Dry Calculated Adjusted Value = null
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report 02 Dry Monitor Hourly Evaluation
Environmental Protection Agency
Page 471 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURMHV-7
Check Name: Initialize 02 Wet Hourly Monitor Data
Related Former Checks:
Applicability:
Description:
Specifications:
Current MHV Parameter = "02 W"
02 Wet Calculated Adjusted Value = null
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report 02 Wet Monitor Hourly Evaluation
Environmental Protection Agency
Page 472 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURMHV-8
Check Name: Check MODC in MHV Record
Related Former Checks:
Applicability:
Description:
Specifications:
Monitor Hourly Mode Status = false
Current MHV Parameter Description = Current MHV Parameter
Complete MHV Record Needed = true
case (Current MHV Parameter)
S02C: Current MHV Record = Current S02 Monitor Hourly Record
Current MHV Component Type = 'S02'
Current MHV System Type = 'S02'
Current MHV Default Parameter = 'S02X'
If (Current MHV Record. ModcCodc == "23")
If (S02 Bypass Code == "BYMAXFS")
Current MHV Fuel Specific Hour = true
else
Current MHV Fuel Specific Hour = false
else if (S()2 Fuel Specific Missing Data == true)
Current MHV Fuel Specific Hour = true
else
Current MHV Fuel Specific Hour = false
If {Current MHV Record. ModcCode not in set {01, 02, 03, 04, 05, 06, 07, 08, 09, 10, 12, 13, 15, 16, 17, 18, 19, 20, 21,
22, 23, 53, 54, 55})
return result A
Else
Monitor Hourly Mode Status = true
NOXC: Current MHV Record = Current NOx Cone Monitor Hourly Record
Current MHV System Type = 'NOXC'
Current MHV Component Type = 'NOX'
Current MHV Default Parameter = 'NOCX'
NOx Cone MODC = null
If (Current MHV Record.ModcCode in set {23, 24})
If (NOx Mass Bypass Code == "BYMAXFS")
Current MHV Fuel Specific Hour = true
else
Current MHV Fuel Specific Hour = false
else if (NOx Mass Fuel Specific Missing Data == true)
Current MHV Fuel Specific Hour = true
else
Current MHV Fuel Specific Hour = false
If (NOx Cone Neededfor Nox Mass Calc == true)
If (CurrentMHVRecord.ModcCode not in set {01, 02, 03, 04, 05, 06, 07, 08, 09, 10, 11, 12, 13, 15, 17, 18, 19,
20, 21, 22, 23, 24, 53, 54, 55})
return result A
Else
Environmental Protection Agency
Page 473 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Monitor Hourly Mode Status = true
Else
Complete MHVRecord Needed = false
If (Current MHV Record. ModcCode not in set {01, 02, 03, 04, 17, 18, 19, 20, 21, 22, 53, 54})
return result B
Else
Monitor Hourly Mode Status = true
NOx Cone MODC = Current MHV Record. ModcCode
FLOW: Current MHV Record = Current Stack Flow Hourly Record
Current MHV Component Type = 'FLOW'
Current MHV System Type = 'FLOW'
Current MHV Default Parameter = 'FLOX'
If (S02 Fuel Specific Missing Data == true OR CO2 Fuel Specific Missing Data == true OR NOx Mass Fuel Specific
Missing Data == true OR Heat Input Fuel Specific Missing Data == true)
Current MHV Fuel Specific Hour = true
else
Current MHV Fuel Specific Hour = false
If {Current MHV Record. ModcCode not in set {01, 02, 03, 04, 05, 06, 07, 08, 09, 10, 11, 12, 20, 53, 54, 55})
return result A
Else
Monitor Hourly Mode Status = true
C02C: Current MHV Record = Current C02 Cone Monitor Hourly Record
Current MHV Component Type = 'C02'
Current MHV System Type = 'C02'
Current MHV Default Parameter = 'C02X'
CO 2C MHV MODC = Current C02 Cone Monitor Hourly Record. ModcCode
If ((C02 Fuel Specific Missing Data == true AND CO2 Cone Checks Needed for C02 Mass Calc == true) OR (Heat
Input Fuel Specific Missing Data == true AND CO2 Cone Checks Needed for Heat Input == true))
Current MHV Fuel Specific Hour = true
else
Current MHV Fuel Specific Hour = false
If ((C02 Cone Checks Needed for Heat Input == true) OR (CO2 Cone Checks Needed for C02 Mass Calc == true))
If (Current MHV Record.ModcCode not in set {01, 02, 03, 04, 06, 07, 08, 09, 10, 12, 17, 18, 20, 21, 53, 54, 55})
return result A
Else
Monitor Hourly Mode Status = true
If ((C02 Diluent Checks Neededfor NOx Rate Calc == true) OR (CO 2 Diluent Neededfor MATS ==
true)) AND (Current MHV Record. ModcCode not in set {01, 02, 03, 04, 17, 20, 21, 53, 54})
return result E
Else
Complete MHV Record Needed = false
If Current MHV Record. ModcCode not in set {01, 02, 03, 04, 17, 18, 20, 21, 53, 54}
return result C
Else
Monitor Hourly Mode Status = true
02D: Current MHV Record = Current 02 Dry Monitor Hourly Record
Current MHV Component Type = '02'
Current MHV System Type = null
Current MHV Default Parameter = '02N'
Environmental Protection Agency
Page 474 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
02 Dry MODC = Current 02 Dry Monitor Hourly Record.ModcCode
If (Current MHV Record .Moisl 11 reBasis is null)
Current MHVParameter Description = "02C"
else
Current MHV Parameter Description = "02C with a MoistureBasis of " + Current MHV Record. IVI0i sture Bas is
If (Heat Input Fuel Specific Missing Data == true AND 02 Dry Checks Needed for Heat Input == true)
Current MHV Fuel Specific Hour = true
else
Current MHV Fuel Specific Hour = false
If (02 Dry Checks Needed for Heat Input == true)
If (Current MHV Record. ModcCode not in set {01, 02, 03, 04, 06, 07, 08, 09, 10, 12, 17, 20, 53, 54, 55})
return result A
Else
Monitor Hourly Mode Status = true
If (((02 Dry Checks Neededfor NOx Rate Calc == true) OR (()2 Dry Neededfor MA TS == true)) AND
(Current MHV Record. ModcCode not in set {01, 02, 03, 04, 17, 20, 53, 54}))
return result E
Else
Complete MHV Record Needed = false
If Current MHV Record. ModcCode not in set {01, 02, 03, 04, 17, 20, 53, 54}
return result D
Else
Monitor Hourly Mode Status = true
02W: Current MHV Record = Current 02 Wet Monitor Hourly Record
Current MHV Component Type = '02'
Current MHV System Type = null
Current MHV Default Parameter = '02N'
02 Wet MODC = Current 02 Wet Monitor Hourly Record ModcCode
If (Current MHV Record.MoistureBasis is null)
Current MHV Parameter Description = "02C"
else
Current MHV Parameter Description = "02C with a MoistureBasis of " + Current MHV Record. IVI0 i sture Basi s
If (Heat Input Fuel Specific Missing Data == true AND 02 Wet Checks Neededfor Heat Input == true)
Current MHV Fuel Specific Hour = true
else
Current MHV Fuel Specific Hour = false
If (02 Wet Checks Needed for Heat Input == true)
If (Current MHV Record. ModcCode not in set {01, 02, 03, 04, 06, 07, 08, 09, 10, 12, 17, 20, 53, 54, 55})
return result A
Else
Monitor Hourly Mode Status = true
If (((02 Wet Checks Needed for NOx Rate Calc == true) OR (02 Wet Neededfor MA TS == true)) AND
(Current MHV Record. ModcCode not in set {01, 02, 03, 04, 17, 20, 53, 54}))
return result E
Else
Complete MHV Record Needed = false
Environmental Protection Agency
Page 475 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
If CurrentMHVRecord.ModcCode not in set {01, 02, 03, 04, 17, 20, 53, 54}
return result D
Else
Monitor Hourly Mode Status = true
H20: Current MHV Record = Current H20 Monitor Hourly Record
Current MHV Parameter = 'H20'
H20 MHVMODC = Current H20 Monitor Hourly Record .ModcCode
ff (H20 Method Code == "MMS")
Current MHV Component Type = "H20"
else
Current MHV Component Type = "DAHS"
Current MHV System Type = null
Current MHV Default Parameter = null'
If (H20 Fuel Specific Missing Data == true)
Current MHV Fuel Specific Hour = true
else
Current MHV Fuel Specific Hour = false
ff {Current MHV Record. ModcCode not in set {01, 02, 03, 04, 06, 07, 08, 09, 10, 12, 21, 53, 54, 55})
return result A
else
Monitor Hourly Mode Status = true
C02CSD:
Current MHV Record = Current C02 Cone Missing Data Monitor Hourly Record
Current MHV Component Type = 'C02'
Current MHV System Type = null
Current MHV Default Parameter = 'C02X'
Current MHV Parameter Description = "C02C (Substitute Data)"
If ((C02 Fuel Specific Missing Data == true AND CO2 Cone Checks Neededfor C02 Mass Calc == true) OR (Heat
Input Fuel Specific Missing Data == true AND CO 2 Cone Checks Neededfor Heat Input == true))
Current MHV Fuel Specific Hour = true
else
Current MHV Fuel Specific Hour = false
If {Current MHV Record. ModcCode not in set {06, 07, 08, 09, 10, 12, 55})
return result A
Else
Monitor Hourly Mode Status = true
02CSD:
if {Current 02 Dry Missing Data Monitor Hourly Record is not null)
Current MHV Record = Current 02 Dry Missing Data Monitor Hourly Record
else
Current MHV Record = Current 02 Wet Missing Data Monitor Hourly Record
Current MHV Component Type = '02'
Current MHV System Type = null
Current MHV Default Parameter = '02N'
Current MHV Parameter Description = "02C (Substitute Data)"
Environmental Protection Agency
Page 476 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
If (Heat Input Fuel Specific Missing Data == true AND 02 Dry Checks Needed for Heat Input == true)
Current MHV Fuel Specific Hour = true
else
Current MHV Fuel Specific Hour = false
If (Current MHV Record. ModcCodc not in set {06, 07, 08, 09, 10, 12, 55})
return result A
Else
Monitor Hourly Mode Status = true
Results:
Result Response
A The MODCCode reported in the MHV record for [param] is invalid.
B You reported a MODCCode of [MODC] in the MHV record for NOXC, but this
MODC is not appropriate when NOX concentration is used in a NOx-diluent system to
calculate the NOx emission rate.
C You reported a MODCCode of [MODC] in the MHV record for C02C, but this MODC
is not appropriate when C02 concentration is only used to calculate a heat input based
emission rate.
D You reported a MODCCode of [MODC] in the MHV record for [param], but this
MODC is not appropriate when 02 concentration is not used to calculate the heat input
rate.
E You reported a MODCCode of [MODC] in the MHV record for [param], but this
MODC is not appropriate when this value is used in a diluent system to calculate the
heat input based emission rate.
Usage:
1
Process/Category:
Emissions Data Evaluation Report —
— C02 Concentration Monitor Hourly Evaluation
2
Process/Category:
Emissions Data Evaluation Report —
— C02C Monitor Hourly Evaluation for Substitute Data
3
Process/Category:
Emissions Data Evaluation Report —
— FLOW Monitor Hourly Evaluation
4
Process/Category:
Emissions Data Evaluation Report —
— H20 Monitor Hourly Evaluation
5
Process/Category:
Emissions Data Evaluation Report —
— NOx Concentration Monitor Hourly Evaluation
6
Process/Category:
Emissions Data Evaluation Report —
— 02 Dry Monitor Hourly Evaluation
7
Process/Category:
Emissions Data Evaluation Report —
— 02 Wet Monitor Hourly Evaluation
8
Process/Category:
Emissions Data Evaluation Report —
— 02C Monitor Hourly Evaluation for Substitute Data
9
Process/Category:
Emissions Data Evaluation Report —
— S02 Monitor Hourly Evaluation
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 477 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURMHV-9
Check Name:
Related Former Checks:
Check Percent Monitor Availability in MHV Record
Applicability:
Description:
Specifications:
Monitor Hourly Pma Status = false
Monitor Hourly Missing Data Status = true
If (Monitor Hourly Mode Status == true)
If ( Current MHV Record.Percent Available is NULL)
if (Complete MHV Record Needed == false)
Monitor Hourly Pma Status = true
else
if {Current MHV Record. ModcCode not in set {01, 02, 03, 04, 16, 17, 18, 19, 20, 21, 22, 53, 54} AND Legacy
Data Evaluation == true)
Monitor Hourly Pma Status = true
return result A
else
return result B
else
if (Complete MHV Record Needed == false)
return result C
else if (Current MHV Record 5>ercentAvail?fole> 100.0 OR
Current MHV Record. PercentAvailable < 0.0)
return result D
Else
case (Current MHV Record. ModcCode)
= 06:
If CurrentMHVRecord.PercentAvailable >= 90.0
Monitor Hourly Pma Status = true
Else
return result E
= 08:
If Current MHV Record.Percent Available >= 95.0
Monitor Hourly Pma Status = true
Else
return result E
= 09:
If Current MH V Record. Pc rcc lit Ay a i lab lc >= 90.0 AND Current MHV Record.Percent Available < 95.0
Monitor Hourly Pma Status = true
Else
return result E
= 10:
If Current MHV Record.PercentAvailable >=80.0 AND Current MHV Record.PercentAvailable < 90.0
Monitor Hourly Pma Status = true
Else if Current MHV Parameter in {FLOW,NOXC} and Current MHV Record.Percent Available >=
90.0
Monitor Hourly Pma Status = true
return result F
Else
Environmental Protection Agency
Page 478 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
return result E
= 11:
If Current MHV Record.PercentAvailable >=90.0
Monitor Hourly Pma Status = true
Else
return result E
All other MODC Codes:
Monitor Hourly Pma Status = true
Results:
Result
A
B
C
D
E
F
Response
You reported an MODCCode of [ModcCode] in the MHV record for [param], but you
did not report a value for PercentAvailable. While this is not required for legacy EDR
data, it is required in all MHV records for ECMPS.
You did not report PercentAvailable in the MHV record for [param].
You reported PercentAvailable in the MHV record for [param], but this value should
not be reported when the monitoring system is only being used to calculate the NOX
emission rate, moisture, and/or C02 concentration. In that case, the percent monitor
availability should be reported in the appropriate DHV record.
The PercentAvailable reported in the MHV record for [param] is invalid. This value
must be between 0 and 100.
You reported an MODCCode of [modcCode] in the MHV record for [param], but the
PercentAvailable is not appropriate for this MODC.
You reported an MODCCode of 10 in the [type] record for [param], but the
PercentAvailability is greater than or equal to 90. When the PMA is greater than or
equal to 90, you should only report an MODC of 10 to indicate that you used the
maximum hourly value in the lookback period for the next available higher load bin,
because there were no quality-assured data in the bin corresponding to the current load
range. (See Part 75.33(c)(5).)
Severity
Informational Message
Critical Error Level 1
Non-Critical Error
Critical Error Level 1
Critical Error Level 1
Informational Message
Usage:
1
Process/Category:
Emissions Data Evaluation Report —
— C02 Concentration Monitor Hourly Evaluation
2
Process/Category:
Emissions Data Evaluation Report —
— C02C Monitor Hourly Evaluation for Substitute Data
3
Process/Category:
Emissions Data Evaluation Report —
— FLOW Monitor Hourly Evaluation
4
Process/Category:
Emissions Data Evaluation Report —
— H20 Monitor Hourly Evaluation
5
Process/Category:
Emissions Data Evaluation Report —
— NOx Concentration Monitor Hourly Evaluation
6
Process/Category:
Emissions Data Evaluation Report —
— 02 Dry Monitor Hourly Evaluation
7
Process/Category:
Emissions Data Evaluation Report —
— 02 Wet Monitor Hourly Evaluation
8
Process/Category:
Emissions Data Evaluation Report —
— 02C Monitor Hourly Evaluation for Substitute Data
9
Process/Category:
Emissions Data Evaluation Report —
— S02 Monitor Hourly Evaluation
Environmental Protection Agency
Page 479 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURMHV-10
Check Name: Check Prior QA'd Hours for MODC 07
Related Former Checks:
Applicability:
Description:
Specifications:
if (Monitor Hourly Mode Status == true AND Monitor Hourly PMA Status == true)
if (Current MHV Record. ModcCodc == 07)
if {Current MHV Parameter in set {02D, 02 W, 02CSD})
Prior QA Hours = count MonitorHourly ValueData records where
MonitorHourlyValueData.ModcCode in set {01, 02, 04, 17, 20, 53} AND
MonitorHourlyValueData.ParameterCode = "02C" AND
(MonitorHourly ValueData.MoistureBasis = Current MHV Record.MoistareBasis OR
MonitorHourlyValueData.MoistureBasis is null) AND
(MonitorHourly ValueData.BeginDate < Current Date OR
(MonitorHourly ValueData.BeginDate = Current Date AND MonitorHourly ValueData.BeginHour <
Current Hour))
else if {Current MHV Parameter == "C02CSD")
Prior QA Hours = count MonitorHourly ValueData records where
MonitorHourlyValueData.ModcCode in set {01, 02, 04, 17, 20, 21, 53} AND
MonitorHourlyValueData.ParameterCode = "C02C" AND
(MonitorHourly ValueData.BeginDate < Current Date OR
(MonitorHourly ValueData.BeginDate = Current Date AND MonitorHourly ValueData.BeginHour <
Current Hour))
else
case {Current MHV Parameter)
S02C: MODC Set = {01, 02, 04, 16, 17, 19, 20, 21, 22, 53}
NOXC: MODC Set = {01, 02, 04, 17, 19, 20, 21, 22, 53}
C02C: MODC Set = {01, 02, 04, 17, 20, 21, 53}
FLOW: MODC Set = {01, 02, 04, 20, 53}
H20: MODC Set = {01, 02, 04, 21, 53}
Prior QA Hours = count MonitorHourly ValueData records where
MonitorHourly ValueData.ModcCode in set MODC Set AND
MonitorHourly ValueData.ParameterCode = Current MHV Record. ParamctcrCodc AND
(MonitorHourly ValueData.BeginDate < Current Date OR
(MonitorHourly ValueData.BeginDate = Current Date AND MonitorHourly ValueData.BeginHour <
Current Hour))
if {Current MHV Parameter in set {NOXC, FLOW})
if {Prior QA Hours > 2160)
Monitor Hourly Missing Data Status = false
return result A
else
Results:
if {Prior QA Hours > 720)
Monitor Hourly Missing Data Status = false
return result A
Result Response Severity
A You reported an MODCCode of 07 in the MHV record for [param], but too many prior Critical Error Level 1
quality assured hours exist in evaluation period for use of this missing data approach.
Environmental Protection Agency
Page 480 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Usage:
1
Process/Category:
Emissions Data Evaluation Report —
— C02 Concentration Monitor Hourly Evaluation
2
Process/Category:
Emissions Data Evaluation Report —
— C02C Monitor Hourly Evaluation for Substitute Data
3
Process/Category:
Emissions Data Evaluation Report —
— FLOW Monitor Hourly Evaluation
4
Process/Category:
Emissions Data Evaluation Report —
— H20 Monitor Hourly Evaluation
5
Process/Category:
Emissions Data Evaluation Report —
— NOx Concentration Monitor Hourly Evaluation
6
Process/Category:
Emissions Data Evaluation Report —
— 02 Dry Monitor Hourly Evaluation
7
Process/Category:
Emissions Data Evaluation Report —
— 02 Wet Monitor Hourly Evaluation
8
Process/Category:
Emissions Data Evaluation Report —
— 02C Monitor Hourly Evaluation for Substitute Data
9
Process/Category:
Emissions Data Evaluation Report —
— S02 Monitor Hourly Evaluation
Environmental Protection Agency
Page 481 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURMHV-11
Check Name: Check Extraneous Data in MHV Record
Related Former Checks:
Applicability:
Description:
Specifications:
Monitor Hourly Null Status = false
Hourly Extraneous Fields = null
if (Current M//K/?6'cwY/.AdjustcdHourly Value is not null AND Current MHV Parameter not in set {S02C, NOXC, FLOW})
append "AdjustedHourly Value" to Hourly Extraneous Fields
if (Current MHV Record.MoistareBasis is not null AND Current MHV Parameter not in set {02D, 02 W, 02CSD})
append "MoistureBasis" to Hourly Extraneous Fields
if (Hourly Extraneous Fields is not null)
return result A
else
Monitor Hourly Null Status = true
Results:
Result Response Severity
A You reported [fieldnames] in the MHV record for [param]. This data should be blank. Non-Critical Error
Usage:
1
Process/Category:
Emissions Data Evaluation Report —
— C02 Concentration Monitor Hourly Evaluation
2
Process/Category:
Emissions Data Evaluation Report —
— C02C Monitor Hourly Evaluation for Substitute Data
3
Process/Category:
Emissions Data Evaluation Report —
— FLOW Monitor Hourly Evaluation
4
Process/Category:
Emissions Data Evaluation Report —
— H20 Monitor Hourly Evaluation
5
Process/Category:
Emissions Data Evaluation Report —
— NOx Concentration Monitor Hourly Evaluation
6
Process/Category:
Emissions Data Evaluation Report —
— 02 Dry Monitor Hourly Evaluation
7
Process/Category:
Emissions Data Evaluation Report —
— 02 Wet Monitor Hourly Evaluation
8
Process/Category:
Emissions Data Evaluation Report —
— 02C Monitor Hourly Evaluation for Substitute Data
9
Process/Category:
Emissions Data Evaluation Report —
— S02 Monitor Hourly Evaluation
Environmental Protection Agency
Page 482 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURMHV-12
Check Name: Check For Correct Use of MODCs
Related Former Checks:
Applicability:
Description:
Specifications:
Current MHVHBHA Value = null
if (Monitor Hourly Mode Status == true AND Monitor Hourly PMA Status == true)
if {Current MHV Record. ModcCode in set {06, 08, 09})
if (Current MHV Parameter in set {02D, 02 W, 02CSD})
Prior MHV Record = latest MonitorHourlyValueData record where
MonitorHourlyValueData.ModcCode in set {01, 02, 03, 04, 17, 20, 53, 54} AND
MonitorHourlyValueData.ParameterCode = "02C" AND
(MonitorHourly ValueData.MoistureBasis = Current MHV Record.MoistureBasis OR
MonitorHourlyValueData.MoistureBasis is null) AND
[MonitorHourly ValueData.Date < Current Date OR
(MonitorHourly ValueData.Date = Current Date AND MonitorHourly ValueData.Hour < Current Hour)]
If Prior MHV Record is not null and is in current reporting period
Next MHV Record = earliest MonitorHourlyValueData record where
MonitorHourly ValueData.ModcCode in set {01, 02, 03, 04, 17, 20, 53, 54} AND
MonitorHourly ValueData.ParameterCode = "02C" AND
(MonitorHourly ValueData.MoistureBasis = Current MHV Record.MoistureBasis OR
MonitorHourly ValueData.MoistureBasis is null) AND
[MonitorHourly ValueData.Date > Current Date OR
(MonitorHourly ValueData.Date = Current Date AND MonitorHourly ValueData.Hour > Current
Hour)]
If Next MHV Record is not null and is in current reporting period
If Prior Mill 7^£'6r;«/.UnadjustcdHourly Value >= 0 AND Next MHV
itecorJ.UnadjustedHourly Value >= 0
Current MHV HBHA Value = (Prior Mill 'Record. U nadjustcdHourlv Value + Next
\1II\ Vtecw^/.U nadjustcdHourlv Value) / 2, ROUNDED to a single decimal.
else
Monitor Hourly Missing Data Status = false
return result A
case (Current MHV Parameter)
S02C:
NOXC:
FLOW:
C02C OR C02CSD:
H20:
MODCSet={01, 02, 03, 04, 16, 17, 19, 20, 21, 22, 53, 54}
MODCSet = {01, 02, 03, 04, 17, 19, 20, 21, 22, 53, 54}
MODC Set = {01, 02, 03, 04, 20, 53, 54}
MODCSet = {01, 02, 03, 04, 17, 20, 21, 53, 54}
MODCSet = {01, 02, 03, 04, 21, 53, 54}
if (Current MHV Parameter in set {H20, C02C})
Environmental Protection Agency
Page 483 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Prior Record = latest MonitorHourly ValueData record or DerivedHourly ValueData record where
ParameterCode = Current MHVParameter AND
ModcCode in set MODC Set AND
(Date < Current Date OR
(Date = Current Date AND Hour < Current Hour ))
If Prior Record is not null and is in current reporting period
Next Record = earliest MonitorHourly ValueData record or DerivedHourly ValueData record
where
ParameterCode = Current MHV Parameter AND
ModcCode in set MODC Set AND
(Date > Current Date OR
(Date = Current Date AND Hour > Current Hour ))
If Next Record is not null and is in current reporting period
If Pr/'oritecordUnadjustedHourlyValue >= 0 AND Next
itecordUnadjustedHourly Value >= 0
Current MHVHBHA Value = (Pr/'oritecordUnadjustedHourlyValue + Next
Record.UnadjustcdHourly Value) / 2, ROUNDED to a single decimal.
else
Monitor Hourly Missing Data Status = false
return result A
else if {Current MHV Parameter == "C02CSD")
Prior MHV Record = latest MonitorHourly ValueData record where
MonitorHourlyValueData.ParameterCode = "C02C" AND
MonitorHourValueData.ModcCode in set MODC Set AND
[MonitorHourly ValueData.Date < Current Date OR
(MonitorHourly ValueData.Date = Current Date AND MonitorHourly ValueData.Hour < Current
Hour)]
If Prior MHV Record is not null and is in current reporting period
Next MHV Record = earliest MonitorHourly ValueData record where
MonitorHourly ValueData.ParameterCode = "C02C" AND
MonitorHourValueData.ModcCode in set MODC Set AND
[MonitorHourly ValueData.Date > Current Date OR
(MonitorHourly ValueData.Date = Current Date AND MonitorHourly ValueData.Hour > Current
Hour)]
If Next MHV Record is not null and is in current reporting period
If Prior MI I\ U nadj ustedHourlv Value >= 0 AND AND Next MHV
itecordUnadjustedHourly Value >= 0
Current MHV HBHA Value = (Prior MI I\ U nadj ustedHourlv Value +
Xext \III\ '/^ccywy/.U nadj ustcdHourly Value) / 2, ROUNDED to a single decimal.
else
Monitor Hourly Missing Data Status = false
return result A
else
Environmental Protection Agency
Page 484 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Prior MHVRecord = latest MonitorHourlyValueData record where
MonitorHourlyValueData.ParameterCode = Current MHV Parameter AND
MonitorHourValueData.ModcCode in set MODC Set AND
[MonitorHourlyValueData.Date < Current Date OR
(MonitorHourlyValueData.Date = Current Date AND MonitorHourlyValueData.Hour < Current
Hour)]
If Prior MHV Record is not null and is in current reporting period
Next MHV Record = earliest MonitorHourlyValueData record where
MonitorHourlyValueData.ParameterCode = Current MHV Parameter AND
MonitorHourValueData.ModcCode in set MODC Set AND
[MonitorHourlyValueData.Date > Current Date OR
(MonitorHourlyValueData.Date = Current Date AND MonitorHourlyValueData.Hour >
Current Hour)]
If Next MHV Record is not null and is in current reporting period
If Prior MI I\ VtecwY/.AdjustcdHourlv Value >= 0 AND Next MHV
Record. AdjustedHourlyValue >= 0
if {Current MHV Parameter == "FLOW")
Current MHVHBHA Value = {Prior MHV
Record. AdjustedHourlyValue + Next MHV
/fecort/. AdjustedHourlyValue) / 2, ROUNDED to the nearest 1000.
else
Current MHV HBHA Value = {Prior MHV
Record. AdjustedHourlyValue + Next MHV
Record.AdjustedHourlyValue) / 2, ROUNDED to a single decimal.
else
Monitor Hourly Missing Data Status = false
return result B
else if {Current MHV Record.ModcCode == "11")
case {Current MHV Parameter)
NOXC: MODC Set = {01, 02, 03, 04, 17, 19, 20, 21, 22, 53, 54}
FLOW: MODC Set = {01, 02, 03, 04, 20, 53, 54}
Prior Measured MHV Record = MonitorHourlyValueData record at latest time for the location where
MonitorHourlyValueData.ModcCode in set MODC Set AND
MonitorHourlyValueData.ParameterCode = Current MHV Parameter AND
(MonitorHourlyValueData.BeginDate < Current Date OR
(MonitorHourlyValueData.BeginDate = Current Date AND MonitorHourlyValueData.BeginHour< Current
Hour))
If Prior Measured MHV Record is not null and is in the current reporting period
PriorDate = Prior Measured MHV Record .BeginDate
PriorHour = Prior Measured MHVRecord .BeginHour
else
PriorDate = the day prior to the beginning of the current reporting period
PriorHour = 23
Next Measured MHV Record = MonitorHourlyValueData record at earliest time for the location where
MonitorHourly ValueData.ModcCode in set MODC Set AND
Environmental Protection Agency
Page 485 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
MonitorHourlyValueData.ParameterCode = Current MHVParameter AND
(MonitorHourlyValueData.BeginDate > Current Date OR
(MonitorHourlyValueData.BeginDate = Current Date AND MonitorHourlyValueData.BeginHour > Current
Hour))
If Next Measured MHV Record is not null and is in the current reporting period
NextDate = Next Measured MHV Record .BeginDate
NextHour = Next Measured MHV Record .BeginHour
else
NextDate = the day after the end of the current reporting period
NextHour = 0
Missing Data Period Length = Count of MonitorHourly ValueData records for the location where
MonitorHourlyValueData.ParameterCode = Current MHV Parameter AND
(MonitorHourly ValueData.BeginDate > PriorDate OR
(MonitorHourly ValueData.BeginDate = PriorDate AND MonitorHourlyValueData.BeginHour >
Prior Hour)) AND
(MonitorHourly ValueData.BeginDate < NextDate OR
(MonitorHourly ValueData.BeginDate = NextDate AND MonitorHourly ValueData.BeginHour <
NextHour))
if (Current MH V Record. Pc rcc lit Ay a i 1 ab 1 c is null OR Current MHV Record. Percent Available >= 95.0)
if (Missing Data Period Length > 24)
Monitor Hourly Missing Data Status = false
return result C
else
if (Missing Data Period Length > 8)
Monitor Hourly Missing Data Status = false
return result C
else if (Current MHV Record ModcCode == "17" AND Monitor Hourly System Status == true)
Hours of Use of Like Kind Analyzer = Count of MonitorHourly ValueData records for the location and reporting period
where
MonitorHourlyValueData.ParameterCode = Current MHV Parameter AND
MonitorHourly ValueData.ModcCode == "17" AND
(MonitorHourly ValueData.BeginDate < Current Date OR
(MonitorHourly ValueData.BeginDate = Current Date AND MonitorHourly ValueData.BeginHour< Current
Hour))
If Hours of Use of Like Kind Analyzer >= 720
First Use of Like Kind Analyzer Record = MonitorHourly ValueData record at earliest time for the location and
and reporting period where
MonitorHourly ValueData.ParameterCode = Current MHV Parameter AND
MonitorHourlyValueData.ModcCode == "17" AND
(MonitorHourly ValueData.BeginDate < Current Date OR
(MonitorHourly ValueData.BeginDate = Current Date AND MonitorHourly ValueData.BeginHour<
Current Hour))
If Current MHV Record IVT o ni to ri ngSy stem ID is not null,
Locate a RA TA TestRecordsByLocationForQAStatus for the location
where the MonitoringSystemID is equal to Current MHK . IVIo nito ri ngSy stc m ID. the
TestResultCode begins with "PASS", and the EndDate/EndHour is after the First Use of Like
Kind Analyzer Record. Date/Hour and on or prior to the Current Date/Current Hour.
If not found,
Environmental Protection Agency
Page 486 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
return result D
else
Locate all Monitor System Component Records for Hour and Location
where the ComponentID is equal to Current MHV Record. Co mpo nc lit ID.
Locate a RA TA TestRecordsByLocationForQAStatus for the location
where the MonitoringSystemID is equal to any MonitoringSystemID in the retrieved Monitor
System Component records, the TestResultCode begins with "PASS", and the EndDate/EndHour
is after the First Use ofLike Kind Analyzer Record .Date/Hour and on or prior to the Current
Date/Current Hour.
If not found,
return result D
Results:
Result Response
A The UnadjustedHourly Value reported in the MHV record for [param] either before or
after the current hour is invalid.
B The AdjustedHourly Value reported in the MHV record for [param] either before or
after the current hour is invalid.
C You reported an MODCCode of 11 in the MHV record for [param], but the length of
the missing data period exceeds the allowable value for use of this missing data
procedure.
D You reported an MODCCode of 17 in the MHV record for [param], indicating the use
of a like-kind analyzer, but you have used a like-kind analyzer to monitor this
parameter for more than 720 hours during this reporting period. You are not allowed t
use a like-kind analyzer for more than 720 hours during a calendar year, unless the
analyzer is identified as a non-redundant backup and a RATA is performed.
Usage:
1
Process/Category:
Emissions Data Evaluation Report —
— C02 Concentration Monitor Hourly Evaluation
2
Process/Category:
Emissions Data Evaluation Report —
— C02C Monitor Hourly Evaluation for Substitute Data
3
Process/Category:
Emissions Data Evaluation Report —
— FLOW Monitor Hourly Evaluation
4
Process/Category:
Emissions Data Evaluation Report —
— H20 Monitor Hourly Evaluation
5
Process/Category:
Emissions Data Evaluation Report —
— NOx Concentration Monitor Hourly Evaluation
6
Process/Category:
Emissions Data Evaluation Report —
— 02 Dry Monitor Hourly Evaluation
7
Process/Category:
Emissions Data Evaluation Report —
— 02 Wet Monitor Hourly Evaluation
8
Process/Category:
Emissions Data Evaluation Report —
— 02C Monitor Hourly Evaluation for Substitute Data
9
Process/Category:
Emissions Data Evaluation Report —
— S02 Monitor Hourly Evaluation
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 487 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURMHV-13
Check Name: Check System in MHV Record
Related Former Checks:
Applicability:
Description:
Specifications:
Current MHVMon Sys Record = null
Monitor Hourly System Status = false
If {Current MHV Parameter == "NOXC" AND NOx Cone Checks Neededfor Nox Mass == false)
if {Current MHV Record Momtoxmg'&yslQvaiD is NOT null AND Legacy Data Evaluation == false)
return result A
else
Monitor Hourly System Status = true
else if {Current MHV Parameter == "C02C" AND CO 2 Cone Checks Neededfor Heat Input == false AND CO 2 Cone Checks Needed
for C(12 Mass Calc == false)
if {Current MHV Record Momtoxmg'&yslQvaiD is NOT null AND Legacy Data Evaluation == false)
return result B
else
Monitor Hourly System Status = true
else if {Current MHV Parameter == "02 W" AND 02 Wet Checks Neededfor Heat Input == false AND 02 Wet Checks Needed to
Support C02 Calculation == false) OR {Current MHV Parameter == "02D" AND 02 Dry Checks Neededfor Heat Input == false AND
02 Dry Checks Needed to Support C02 Calculation == false)
if {Current MHV Record Momtoxmg'iystQvaiD is NOT null AND Legacy Data Evaluation == false)
return result G
else
Monitor Hourly System Status = true
else if {Current MHV Parameter in set {C02CSD, 02CSD})
if Current MHV Record.MomtoringSystemlD is NOT null
return result F
else
Monitor Hourly System Status = true
case {Current MHV Parameter)
S02C:
NOXC:
C02C, 02D, or 02W:
FLOW:
H20:
MODCSet={01, 02, 03, 04, 16, 17, 18, 19, 20, 21, 22}
MODCSet={01, 02, 03, 04, 17, 18, 19, 20, 21, 22}
MODCSet = {01, 02, 03, 04, 17, 18, 20, 21}
MODC Set = {01, 02, 03, 04, 20}
MODCSet = {01, 02, 03, 04, 21}
If {Current MHVRecord.ModcCode in set MODC Set)
if Current MHV Record. IVT o ni to ri ngSy stem ID is null
return result C
Environmental Protection Agency
Page 488 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
else
Current MHVMon Sys Record = find active MonitoringSy stemData record for location where
MonitoringSystemData.MonitoringSystemlD = Current MHVTtecon/.MonitoringSystemID
if Current MHV Mon Sys Record is null
return result D
else
if (Current MHV Parameter in set {02D, 02W})
if (Legacy Data Evaluation == true
if (Current MHV Mon Sys Record. Sy s tc mTy pc C o dc not in set
{H20,02,C02,N0XC,N0X})
return result E
else
Monitor Hourly System Status = true
else if (Current MHV Mon Sys Record. Sy s tc mTy pc C o dc not in {02, C02})
return result E
else
Monitor Hourly System Status = true
else if (Current MHV Parameter = "H20")
if (Current MHV Mon Sys Record. Sy s t c mTy pc C o dc not in {H20T, H20M})
return result E
else
Monitor Hourly System Status = true
else
if (Current MHV Mon Sys Record. Sy stc mTy pcCodc <> Current MHV System Type)
If (Current MHV Parameter == "C02C" AND Legacy Data Evaluation == true AND
Current MHV Mon Sys Record.SyslcmTypc C ode == "NOX")
Monitor Hourly System Status = true
else
return result E
else
Monitor Hourly System Status = true
else if (Current MHV Record MomtormgSystQmiD is NOT null AND Monitor Hourly MODC Status == true AND Current
MHV Record. ModcCode not in set {05, 16, 53, 54} )
return result F
else
Monitor Hourly System Status = true
Environmental Protection Agency
Page 489 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
Results:
Result Response
A You reported a MonitoringSystemID in the MHV record for NOXC, but this field
should be blank when the NOX concentration is used to calculate the NOX emission
rate as part of a NOX-diluent system.
B You reported a MonitoringSystemID in the MHV record for C02C, but this field
should be left blank when C02 concentration is not used to calculate C02 mass or heat
input.
C You did not report a MonitoringSystemID in the MHV record for [param]. This
information is required when you report measured data.
D You reported MonitoringSystemID [ID] in the MHV record for [param], but there is no
Monitoring System record for this system in your monitoring plan that was active
during the hour.
E You reported MonitoringSystemID [ID] in the MHV record for [param], but this
SystemTypeCode for this monitoring system is not appropriate.
F You reported a MonitoringSystemID in the MHV record for [param], but this is not
appropriate when substitute data is used.
G You reported a MonitoringSystemID in the MHV record for [param], but this field
should be left blank when 02 concentration is not used to calculate C02 concentration
or heat input.
Usage:
1
Process/Category:
Emissions Data Evaluation Report —
— C02 Concentration Monitor Hourly Evaluation
2
Process/Category:
Emissions Data Evaluation Report —
— C02C Monitor Hourly Evaluation for Substitute Data
3
Process/Category:
Emissions Data Evaluation Report —
— FLOW Monitor Hourly Evaluation
4
Process/Category:
Emissions Data Evaluation Report —
— H20 Monitor Hourly Evaluation
5
Process/Category:
Emissions Data Evaluation Report —
— NOx Concentration Monitor Hourly Evaluation
6
Process/Category:
Emissions Data Evaluation Report —
— 02 Dry Monitor Hourly Evaluation
7
Process/Category:
Emissions Data Evaluation Report —
— 02 Wet Monitor Hourly Evaluation
8
Process/Category:
Emissions Data Evaluation Report —
— 02C Monitor Hourly Evaluation for Substitute Data
9
Process/Category:
Emissions Data Evaluation Report —
— S02 Monitor Hourly Evaluation
Seventy
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Non-Critical Error
Critical Error Level 1
Environmental Protection Agency
Page 490 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURMHV-14
Check Name: Check System Designation Code for System in MHV Record
Related Former Checks:
Applicability:
Description:
Specifications:
If (Monitor Hourly Mode Status == true AND Monitor Hourly System Status == true AND Current MHV Mon Sys Record is not null)
case {Current MHV Record. ModcCode)
01 OR 17: If {Current MHV Mon Sys Record. SystemDesignationCode NOT in set {P, PB})
return result A
02: If {Current MHV Mon Sys Record. SystemDesignationCode NOT in set {B, RB, DB}
return result B
04: If {Current MHV Mon Sys Record. SystemDesignationCode <> "RM")
return result C
22: If {Current MHV Mon Sys Record. SystemDesignationCode <> "CI")
return result D
Results:
Result
A
B
C
D
Response
You reported an MODCCode of [modcCode] in the MHV record for [param], but
MonitoringSystemID [ID] is not a primary system.
You reported an MODCCode of 02 in the MHV record for [param], but
MonitoringSystemID [ID] is not a backup system.
You reported an MODCCode of 04 in the MHV record for [param], but
MonitoringSystemID [ID] is not a reference method system.
You reported an MODCCode of 22 in the MHV record for [param], but
MonitoringSystemID [ID] is not a certified inlet system.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1
Process/Category:
Emissions Data Evaluation Report —
— C02 Concentration Monitor Hourly Evaluation
2
Process/Category:
Emissions Data Evaluation Report —
— FLOW Monitor Hourly Evaluation
3
Process/Category:
Emissions Data Evaluation Report —
— H20 Monitor Hourly Evaluation
4
Process/Category:
Emissions Data Evaluation Report —
— NOx Concentration Monitor Hourly Evaluation
5
Process/Category:
Emissions Data Evaluation Report —
— 02 Dry Monitor Hourly Evaluation
6
Process/Category:
Emissions Data Evaluation Report —
— 02 Wet Monitor Hourly Evaluation
7
Process/Category:
Emissions Data Evaluation Report —
— S02 Monitor Hourly Evaluation
Environmental Protection Agency
Page 491 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURMHV-15
Check Name: Check Component in MHV Record
Related Former Checks:
Applicability:
Description:
Specifications:
Monitor Hourly Component Status = false
if {Current MHV Parameter NOT in set {C02CSD, 02CSD})
case (Current MHV Parameter)
S02C: MODCSet = {01, 02, 03, 04, 16, 17, 18, 19, 20, 21, 22, 53}
NOXC: MODCSet = {01, 02, 03, 04, 17, 18, 19, 20, 21, 22, 53}
C02C, 02D, 02W: MODCSet = {01, 02, 03, 04, 17, 18, 20, 21, 53}
FLOW: MODCSet = {01, 02, 03, 04, 20, 53}
H20: MODCSet = {01, 02, 03, 04, 21, 53}
If (Current MHV Record.ModcCode in set MODC Set)
if Current MHV Record. ComponentID is null
If (Current MHV Parameter == "FLOW" and Current MH V Record. IVT o ni to ri ngSy stem ID is not null)
Count Mon Sys Comp Record = count active MonitoringSystemComponent record for location where
MonitoringSystemComponentData .ComponentTypeCode = "FLOW" AND
MonitoringSystemComponentData.MonitoringSystemID = Current MHV
Record. IVI o n i t o ri ng Sy s t e m ID
If (Count Mon Sys Comp Record < 2)
return result A
Otherwise,
return result A
else
Current MHV Component Record = find ComponentData record where ComponentData. ComponentID = Current
MHV Record. ComponentID
If Current MHV Component Record. ComponentTypeCode <> Current MHV Component Type
return result B
else if Monitor Hourly ModcStatus == true AND Current MHV Record. ModcCode == 17 AND CurrentMHV
Component Record. Componentldentifier does not begin with "LK"
return result C
else if (Monitor Hourly System Status == true AND Current MHV Mon Sys Record is not null)
Count Mon Sys Comp Record = count active MonitoringSystemComponent record for location where
MonitoringSystemComponentData .ComponentID = Current MHV Record. ComponentID AND
MonitoringSystemComponentData.MonitoringSystemID = CurrentMHV
Record. IVI o n i t o ri ng Sy s t c m ID
If Count Mon Sys Comp Record = 0
return result D
Else
Monitor Hourly Component Status= true
Environmental Protection Agency
Page 492 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Else
Monitor Hourly Component Status = true
else
if Current MHVRecord. ComponentID is NOT null
return result E
else
Monitor Hourly Component Status = true
else
if Current MHV Record. ComponentID is NOT null
return result E
else
Monitor Hourly Component Status = true
Results:
Result
A
B
C
D
Usage:
Response
You did not report a ComponentID in the MHV record for [param].
You reported ComponentID [ID] in the MHV record for [param], but this is not an
[comptype] component.
You reported an MODCCode of 17 in the MHV record for [param], which indicates
that the component is a like-kind analyzer, but the ComponentID does not begin with
LK.
You reported MonitoringSystemID [sys] ComponentID [ID] in the MHV record for
[param], but there is no MonitorSystemComponent record for this system and
component in your monitoring plan that was active during the hour.
You reported a ComponentID in the MHV record for [param], but this field should be
blank whenever missing data substitution is performed.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Non-Critical Error
1
Process/Category:
Emissions Data Evaluation Report —
— C02 Concentration Monitor Hourly Evaluation
2
Process/Category:
Emissions Data Evaluation Report —
— C02C Monitor Hourly Evaluation for Substitute Data
3
Process/Category:
Emissions Data Evaluation Report —
— FLOW Monitor Hourly Evaluation
4
Process/Category:
Emissions Data Evaluation Report —
— H20 Monitor Hourly Evaluation
5
Process/Category:
Emissions Data Evaluation Report —
— NOx Concentration Monitor Hourly Evaluation
6
Process/Category:
Emissions Data Evaluation Report —
— 02 Dry Monitor Hourly Evaluation
7
Process/Category:
Emissions Data Evaluation Report —
— 02 Wet Monitor Hourly Evaluation
8
Process/Category:
Emissions Data Evaluation Report —
— 02C Monitor Hourly Evaluation for Substitute Data
9
Process/Category:
Emissions Data Evaluation Report —
— S02 Monitor Hourly Evaluation
Environmental Protection Agency
Page 493 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURMH V -16
Check Name:
Check Pre-Bias-Adjusted Value
Related Former Checks:
Applicability:
Description:
Specifications:
Monitor Hourly Preadjusted Value Status = false
S02C: MODCSet = {01, 02, 03, 04, 16, 17, 18, 19, 20, 21, 22, 53, 54}
NOXC: MODCSet = {01, 02, 03, 04, 17, 18, 19, 20, 21, 22, 53, 54}
FLOW: MODCSet = {01, 02, 03, 04, 20, 53, 54}
If (Current MHVRecord. ModcCode in set MODC Set)
If (Current M//K/?6'«;/y/.U nadjustedHourly Value is null AND
Current MHV Record. ModcCode not in set {04, 19, 20, 53, 54})
return result A
else if (Current M//K/?6'«;/y/.U nadjustedHourly Value < 0.0 AND
Current MHV Record. ModcCode not in set {16, 21} )
return result A
else if (Current M//K/?6'«.»/y/.U nadjustedHourly Value > 2 AND
Current MHV Record. ModcCode == 16)
return result B
else if (Current M//K/?6'«.»/y/.U nadjustedHourly Value > 0 AND
Current MHV Record. ModcCode == 21)
return result C
else if {Current MHV Parameter in set {S02C, NOXC} and Current M//K/?6'cmy/.U nadjustedHourly Value is not rounded to 1
decimal place)
return result F
else if {Current MHV Parameter == "FLOW" and Current MHV Record. U nadjustedHourly Value is not rounded to the nearest
1000)
return result F
else
Monitor Hourly Preadjusted Value Status = true
if {Current MHV Max Min Value is not null)
if (Current M//K/?6'cmy/.U nadjustedHourly Value > Current MHV Max Min Value)
return result D
else if {Monitor Hourly Mode Status == true)
If (Current MHV Record \) nadjustedHourly Value is not null)
return result E
Else
Monitor Hourly Preadjusted Value Status = true
Environmental Protection Agency
Page 494 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result Response Severity
A The UnadjustedHourly Value reported in the MHV record for [param] is missing or Critical Error Level 1
invalid.
B You reported an MODCCode of 16 in the MHV record for [param], but the Critical Error Level 1
UnadjustedHourly Value exceeds 2.
C You reported an MODCCode of 21 in the MHV record for [param], but the Critical Error Level 1
UnadjustedHourly Value is greater than 0.
D Warning: The UnadjustedHourly Value reported in the MHV record for [param] is in Informational Message
excess of the maximum value listed in the monitoring plan. Sources are required to
periodically (at least once annually) evaluate the appropriateness of these maximum
values in the monitoring plan and make proper adjustments when necessary.
Adjustments may include the need to update Span and/or Default values. You should
investigate the cause of these exceedances and determine whether adjustments to your
monitoring systems or monitoring plan are necessary.
E You reported an MODCCode of [modcCode] in the MHV record for [param], so you Critical Error Level 1
should not have reported a value for the UnadjustedHourly Value.
F You reported [fieldname] in the [type] record for [param] that is not rounded to the Critical Error Level 1
appropriate precision for that parameter.
Usage:
1 Process/Category: Emissions Data Evaluation Report FLOW Monitor Hourly Evaluation
2 Process/Category: Emissions Data Evaluation Report NOx Concentration Monitor Hourly Evaluation
3 Process/Category: Emissions Data Evaluation Report S02 Monitor Hourly Evaluation
Environmental Protection Agency
Page 495 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURMHV-17
Check Name: Verily Consistency Between NOx Emission Rate and NOx Concentration
Related Former Checks:
Applicability:
Description:
Specifications:
If (NOx Cone Needed for NOx Rate Calc == true AND Monitor Hourly Mode Status == true)
if (Current MHV Record.MODCCode not in set {01, 02, 03, 04, 17, 18, 19, 20, 21, 22, 53} )
return result A
else if (Current MHV Record. MODCCode == 21 AND NOx Emission Rate MODC not in set {14, 21})
return result A
elseif (Current MHV Record. MODCCode == 22 AND NOx Emission Rate MODC not in set{14, 22})
return result A
Results:
Result Response Severity
A You reported an MODCCode of [MODC] in the MHV record for NOXC that is Critical Error Level 1
inconsistent with MODCCode of [NOX ER MODC] reported in the DHV record for
NOXR.
Usage:
1 Process/Category: Emissions Data Evaluation Report NOx Concentration Monitor Hourly Evaluation
Environmental Protection Agency
Page 496 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURMHV-18
Check Name: Determine Maximum or Minimum Value for Parameter in MHV Record
Related Former Checks:
Applicability:
Description:
Specifications:
Current MHV Max Min Value = null
If {Current MHV Parameter == "H20")
If (H20 Missing Data Approach == "MAX")
Current MHV Default Parameter = "H20X"
Else If (H20 Missing Data Approach == "MIN")
Current MHV Default Parameter = "H20N"
else if {Current MHV Record. ModcCode== 12)
return result A
If {Monitor Hourly Mode Status == true AND Current MHV Default Parameter is not null)
If {Current MHV Record. ModcCode in set {12, 23} AND Current MHV Fuel Specific Hour = true)
If Current Hourly Op Record. Fucl Code is not null
Current MHV Missing Data Fuel = Current Hourly Op Record. FuelCode
Count active MonitoringDefaultData record for location where
ParameterCode = Current MHV Default Parameter
FuelCode = Current Hourly Op Record.FuelCode
DefaultPurposeCode = "MD" // Missing Data
OperatingCode in set {A,U} // Not Controlled
if {count >1)
return result B
else if {count == 0)
return result C
else
Default Record = the single matched record
if (Defeat It Re card. D c fa ill t V a 1 lie > 0)
Current MHV Max Min Value = Default Record. DefaultValue
else
return result D
else if {Current MHV Record. ModcCode in set {13, 24} AND Current MHV Fuel Specific Hour == true)
If Current Hourly Op Record.FuelCode is not null
Current MHV Missing Data Fuel = Current Hourly Op Record. FuelCode
Count active MonitoringDefaultData record for location where
ParameterCode = Current MHV Default Parameter
FuelCode = Current Hourly Op Record .FuelCode
DefaultPurposeCode = "MD" // Missing Data
OperatingCode in == "C" // Controlled
if {count >1)
return result B
Environmental Protection Agency
Page 497 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
else if (count == 0)
return result C
else
Default Record = the single matched record
if (Defeat It Record. D c fa u 11V a 1 lie > 0)
Current MHV Max Min Value = Default Record. Default Value
else
return result D
else if {Current MHV Record. ModcCode <> 15)
If {Current MHV Parameter in set {H20, 02W, 02D, 02CSD})
if {Current MHV Default Parameter is not null)
Current MHV Missing Data Fuel = "NFS"
else
if {Current MHV Parameter in set {02W, 02D} AND Current MHV Record. ModcCode == 20)
Current MHV Default Parameter = "02X"
Count active MonitoringDefaultData record for location where
ParameterCode = Current MHV Default Parameter
FuelCode = "NFS"
DefaultPurposeCode = "DC" // diluent cap
else
Count active MonitoringDefaultData record for location where
ParameterCode = Current MHV Default Parameter
FuelCode = "NFS"
DefaultPurposeCode = "MD" // missing data
if {count >1)
return result B
else if {{Current MHV Parameter == "02D" AND 02 Dry Checks Needed for Heat Input == false) OR
{Current MHV Parameter == "02W" AND 02 Wet Checks Neededfor Heat Input == false))
Current MHV Max Min Value = 0
else if {count == 0)
return result C
else
Default Record = the single matched record
if (Defeat It Record. D c Ian 11V a 1 lie > 0)
Current MHV Max Min Value = Default Record. DefaultValue
else
return result D
If {Current MHV Component Type == 'FLOW")
Current MHV Span Description = 'FLOW"
Monitor Span Record Count = Find active MonitoringSpanData records for location where
MonitoringSpanData .ComponentTypeCode = 'FLOW"
else
Environmental Protection Agency
Page 498 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Current MHV Span Description = Current MHV Component Type + " with a SpanScale of H"
Monitor Span Record Count = Find active MonitoringSpanData records for location where
MonitoringSpanData .ComponentTypeCode = Current MHV Component Type AND
MonitoringSpanData. SpanScaleCode = "H"
if {Monitor Span Record Count > 1)
return result E
else if (Monitor Span Record Count = 0)
return result F
else
Current Monitor Span Record = the single matched record
If {Current MHV Record. ModcCode == 19)
if Current Monitor Span .RecordDefaultHighRange > 0)
Current MHV Max Min Value = Current Monitor Span i?ecor0)
Current MHV Max Min Value = Current Monitor Span
itecorii.FlowFullScaleRange * 2
else
return result G
else
if Current Monitor Span Record.FullScaleRange >0)
Current MHV Max Min Value = Current Monitor Span
Record. Fu 11 Sea 1 c Ra ngc * 2
else
return result G
else
if {Current MHV Parameter == "FLOW")
if Current Monitor Span RecordMPYValue > 0)
Current MHV Max Min Value = Current Monitor Span
Record. MPF V alue
else
return result G
else
if Current Monitor Span Record. IVT PC Va 1 lie > 0)
Current MHV Max Min Value = Current Monitor Span
Record. MPC Value
else
return result G
else if {Current MHV Parameter in set {S02C, NOXC})
Current MHV Span Description = Current MHV Component Type + " with a SpanScale of L"
Monitor Span Record Count = Find active MonitoringSpanData records for location where
MonitoringSpanData .ComponentTypeCode = Current MHV Component Type AND
MonitoringSpanData.SpanScaleCode = "L"
if {Monitor Span Record Count > 1)
Environmental Protection Agency
Page 499 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
return result E
else if (Monitor Span Record Count = 0)
return result F
else
Current Monitor Span Record = the single matched record
if (Current MHV Record. ModcCodc == 20)
if Current Monitor Span .RecordFullScaleRange > 0)
Current MHV Max Min Value = Current Monitor Span
Record. Fill 1 SealcRange * 2
else
return result G
else if {Current MHV Record. ModcCode in set {13, 24})
if Current Monitor Span Record .MECValue > 0)
Current MHV Max Min Value = Current Monitor Span
Record. MEC V alue
else
return result G
if Current Monitor Span Record. SpanValue >0)
Current MHV Max Min Value = Current Monitor Span
Record. SpanValue
else
return result G
else
Results:
Result
A
Response
The missing data default parameter for H20 could not be determined, because you used
both Standard and Inverse Part 75 missing data approaches during the hour.
You reported more than one applicable [param] Default record with a FuelCode of
[FuelCode] in your monitoring plan for the hour.
You did not report an applicable [param] Default record with a FuelCode of
[FuelCode].
The values reported in the applicable [param] Default record with a FuelCode of
[FuelCode] are invalid.
You reported more than one active span record for [key] in your monitoring plan for the
hour.
You did not report an active span record for [key] in your monitoring plan for the hour.
The values reported in the applicable span record for [key] are invalid.
Severity
Critical Error Level 2
B
Critical Error Level 1
C
Critical Error Level 1
D
Critical Error Level 1
E
Critical Error Level 1
F
G
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 500 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Usage:
1
Process/Category:
Emissions Data Evaluation Report —
— C02 Concentration Monitor Hourly Evaluation
2
Process/Category:
Emissions Data Evaluation Report —
— C02C Monitor Hourly Evaluation for Substitute Data
3
Process/Category:
Emissions Data Evaluation Report —
— FLOW Monitor Hourly Evaluation
4
Process/Category:
Emissions Data Evaluation Report —
— H20 Monitor Hourly Evaluation
5
Process/Category:
Emissions Data Evaluation Report —
— NOx Concentration Monitor Hourly Evaluation
6
Process/Category:
Emissions Data Evaluation Report —
— 02 Dry Monitor Hourly Evaluation
7
Process/Category:
Emissions Data Evaluation Report —
— 02 Wet Monitor Hourly Evaluation
8
Process/Category:
Emissions Data Evaluation Report —
— 02C Monitor Hourly Evaluation for Substitute Data
9
Process/Category:
Emissions Data Evaluation Report —
— S02 Monitor Hourly Evaluation
Environmental Protection Agency
Page 501 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURMHV-19
Check Name: Check Adjusted Hourly Value in MHV Record
Related Former Checks:
Applicability:
Description:
Specifications:
Monitor Hourly Adjusted Value Status = false
if (Monitor Hourly Mode Status == true AND Monitor Hourly Missing Data Status == true AND
(Monitor Hourly Pma Status == true OR Current MHV Record .ModcCode NOT in set {06, 07, 08, 09, 10, 11}))
If (Current MHV Parameter <> "NOXC" OR NOx Cone Neededfor Nox Mass Calc == true)
If (Current MHV Parameter == "FLOW")
set Current MHV Precision to -3.
else
set Current MHV Precision to 1.
case {Current MHV Record. ModcCode)
= 21: Current MHV Calculated Adjusted Value = 0
if (Current MHV Record. AdjustedHourly Value == 0)
Monitor Hourly Adjusted Value Status = true
else
return result A
= 16: Current MHV Calculated Adjusted Value = 2
if (Current MH V Record. Adj ustcdHourly Va 1 lie == 2)
Monitor Hourly Adjusted Value Status = true
else
return result B
= 12 OR = 23:
If (Current MHV Max Min Value is not null)
Current MHV Calculated Adjusted Value = Current MHV Max Min Value
if (Current MH V Record. AdjustedHourlyValue == Current MHV Max Min Value)
Monitor Hourly Adjusted Value Status = true
else
return result C
= 13 OR 24:
If (Current MHV Max Min Value is not null)
Current MHV Calculated Adjusted Value = Current MHV Max Min Value
if (Current MHV Record. AdjustedHomlyValue == Current MHV Max Min Value)
Monitor Hourly Adjusted Value Status = true
else
return result D
= 06: If (Current MHVHBHA Value is not null)
Current MHV Calculated Adjusted Value = Current MHVHBHA Value
If (Current MHV Record. Ad) ustcdHourly Value >= 0)
if ( Current MHV Record. Ad) ustcdHourly Value == Current MHV Calculated Adjusted Value)
Monitor Hourly Adjusted Value Status = true
else
Environmental Protection Agency
Page 502 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
return result G
else
return result H
else
If (Current MHV Record. AdjustedHourly Value >= 0)
If (Current MHV Record. Ad) ustedHourly Value is not rounded to Current MHV Precision)
return result L
else
Current MHV Calculated Adjusted Value = Current MHV
Record. Adj ustedHourly Value
Monitor Hourly Adjusted Value Status = true
If {Current MHV Max Min Value is not null)
if (Current MHV Record. AdjustedHomlyValue > Current MHV Max Min
Value)
If (Current MHV Parameter == "S02C" and Current MHV
Record. Ad) ustcdH ourly Value > Current MHV Max Min Value * 2)
return result O
Otherwise,
return result K
Else
return result H
= 08 OR 09:
If (Current MHV Record. Ad) ustedHourly Value >= 0)
If (Current MHV HBHA Value is not null AND Current MHV HBHA Value > Current MHV
Record. Adj ustedHourly Va 1 lie AND (Unit is Load Based == true or Current MHV Parameter <>
"NOXC")
Current MHV Calculated Adjusted Value = Current MHV HBHA Value
return result I
else
If (Current MHV Record. Adi) ustedHourly Value is not rounded to Current MHV Precision)
return result L
else
Current MHV Calculated Adjusted Value = Current MHV
Record. Adj ustedHourly Value
Monitor Hourly Adjusted Value Status = true
If (Current MHV Max Min Value is not null)
if (Current MHV Record.KdjustQdRouxXyNaXuQ > Current MHV Max Min
Value)
If (Current MHV Parameter == "S02C" and Current MHV
Record. Adi) ustedHourly Value > Current MHV Max Min Value * 2)
return result O
Otherwise,
return result K
Else
return result H
= 04, 05, 07, 10, 11, 15, 53, 54, OR 55:
If (Current MHV Record. Adj ustedHourly Value >= 0)
If (Current MHV Record. Adi) ustedHourly Value is not rounded to Current MHV Precision)
Environmental Protection Agency
Page 503 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
return result L
else
Current MHV Calculated Adjusted Value = Current Adj ustedHourly Value
Monitor Hourly Adjusted Value Status = true
If (Current MHV Max Min Value is not null)
if {Current MH V Record. AdjustedHourlyValue > Current MHV Max Min Value)
If {Current MHV Parameter == "S02C" and Current MHV
Record. Adj ustcdHourly Value > Current MHV Max Min Value * 2)
If the Current MHV Record.ModcCode == 10
return result P
Otherwise,
return result O
Otherwise,
return result K
Else
return result H
= All Other Codes:
If (Current MHV Record. Ad) ustedHourly Value >= 0)
f (Current MHV Record.ModcCode in set {19, 20} AND Current MHV
Record. U nadj ustedHourly Value is null)
If {Current MHV Max Min Value is not null)
if {Current MH V Record. AdjustedHourlyValue == Current MHV Max Min Value)
Current MHV Calculated Adjusted Value = Current MHV
Record. Adj ustedHourly Val uc
Monitor Hourly Adjusted Value Status = true
else
if {Current MHV Record. ModcCode == "19")
return result M
else
return result N
else if {Current MHV Record. A dj u s t cd H o u r ly Va 1 uc is not rounded to Current MHV Precision)
return result L
else
Monitor Hourly Adjusted Value Status = true
Else
return result H
If (Current MHV Record. k
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result Response Severity
A You reported an MODCCode of 21 in the MHV record for [param], but the Critical Error Level 1
AdjustedHourly Value does not equal 0.
B You reported an MODCCode of 16 in the MHV record for [param], but the Critical Error Level 1
AdjustedHourly Value does not equal 2.
C You reported an MODCCode of [modcCode] in the MHV record for [param], but the Critical Error Level 1
AdjustedHourly Value does not equal the maximum potential value reported in the
[comptype] span or fuel-specific default record in your monitoring plan.
D You reported an MODCCode of 13 or 24 in the MHV record for [param], but the Critical Error Level 1
AdjustedHourly Value does not equal the maximum expected value reported in the
[comptype] span or fuel-specific default record in your monitoring plan.
G You reported an MODCCode of 06 in the MHV record for [param], but the Critical Error Level 1
AdjustedHourly Value does not equal average of measured hour before and measured
hour after.
H The AdjustedHourly Value reported in the MHV record for [param] is invalid. Critical Error Level 1
I You reported an MODCCode of [MODCCode] in the MHV record for [param], but you Critical Error Level 1
reported an AdjustedHourly Value that is less than the average of the measured hour
before and measured hour after.
J You reported an AdjustedHourly Value in the MHV record for NOXC. This field Critical Error Level 1
should be blank when the NOX concentration is used to calculate the NOX emission
rate as part of a NOX system.
K Warning: The AdjustedHourly Value reported in the MHV record for [param] is in Informational Message
excess of the maximum value listed in the monitoring plan. Sources are required to
periodically (at least once annually) evaluate the appropriateness of these maximum
values in the monitoring plan and make proper adjustments when necessary.
Adjustments may include the need to update Span and/or Default values. You should
investigate the cause of these exceedances and determine whether adjustments to your
monitoring systems or monitoring plan are necessary.
L You reported [fieldname] in the [type] record for [param] that is not rounded to the Critical Error Level 1
appropriate precision for that parameter.
M You reported an MODCCode of 19 in the MHV record for [param], but the Critical Error Level 1
AdjustedHourly Value does not equal the DefaultHighRange reported in the [comptype]
span record in your monitoring plan.
N You reported an MODCCode of 20 in the MHV record for [param], but the Critical Error Level 1
AdjustedHourly Value does not equal 200 percent of the FullScaleRange reported in the
[comptype] span record in your monitoring plan.
O The AdjustedHourly Value reported in the MHV record for [param] is in excess of the Critical Error Level 2
maximum value listed in the monitoring plan. Sources are required to periodically (at
least once annually) evaluate the appropriateness of these maximum values in the
monitoring plan and make proper adjustments when necessary. Adjustments may
include the need to update Span and/or Default values. You should investigate the
cause of these exceedances and determine whether adjustments to your monitoring
systems or monitoring plan are necessary.
P The AdjustedHourly Value reported in the MHV record for [param] is in excess of the Informational Message
maximum value listed in the monitoring plan. Sources are required to periodically (at
least once annually) evaluate the appropriateness of these maximum values in the
monitoring plan and make proper adjustments when necessary. Adjustments may
include the need to update Span and/or Default values. You should investigate the
cause of these exceedances and determine whether adjustments to your monitoring
systems or monitoring plan are necessary.
Usage:
1 Process/Category: Emissions Data Evaluation Report FLOW Monitor Hourly Evaluation
2 Process/Category: Emissions Data Evaluation Report NOx Concentration Monitor Hourly Evaluation
3 Process/Category: Emissions Data Evaluation Report S02 Monitor Hourly Evaluation
Environmental Protection Agency
Page 505 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURMHV-20
Check Name:
Check Unadjusted Hourly Value in MHV Record
Related Former Checks:
Applicability:
Description:
Specifications:
Monitor Hourly Unadjusted Value Status = false
if (Monitor Hourly Mode Status == true AND Monitor Hourly Missing Data Status == true AND
(Monitor Hourly Pma Status == true OR Current MHV Record .ModcCode NOT in set {06, 07, 08, 09, 10, 11}))
Calculated Unadjusted Value = null
case {Current MHV Record. ModcCode)
= 21: Calculated Unadjusted Value = 0
if (CurrentM//K/?6'cwY/.UnadjustcdHourly Value == 0)
If {Current MHV Parameter == "C02C" and Current Hourly Op Record. LoadRa ngc is greater than 1,
return result L
else
Monitor Hourly Unadjusted Value Status = true
Calculated Unadjusted Value = Current MHV Max Min Value
if {Current M//^./te£w= 0)
If {Current MHV Max Min Value is not null)
If (Current MHV Parameter begins with "02" AND Current M//K/?6'cw
20.9)
Calculated Unadjusted Value = Current MHV Max Min Value
return result K
else if Current MHV Parameter == "C02C" AND C.'M/7*6'rt?M//K/?6'cwY/.UnadjustcdHourly Value >
Current MHV Max Min Value)
Calculated Unadjusted Value = Current MHV Max Min Value
return result C
elseif (Current MHV Record U nadj ustedHourly Value is not rounded to one decimal place)
return result I
else
Calculated Unadjusted Value = Current A///K/?6'cwy/.U nadj ustedHourly Value
Monitor Hourly Unadjusted Value Status = true
else
return result A
= 12 OR = 23:
If {Current MHV Max Min Value is not null)
else
return result E
= 06: If {Current MHVHBHA Value is not null)
Calculated Unadjusted Value = Current MHVHBHA Value
Environmental Protection Agency
Page 506 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
If (Current MH V Record. U nadj ustcdHourly Va 1 lie >= 0)
if ( Current A///K/?6'cwy/.U nadj ustcdHourly Value == Calculated Unadjusted Value)
Monitor Hourly Unadjusted Value Status = true
else
return result D
else
return result E
else
If (Current MH V Record. U nadj ustcdHourly Va 1 uc >= 0)
If (Current MHV Record U nadj ustcdHourly Value is not rounded to one decimal place)
return result I
else
Calculated Unadjusted Value = Current A///K/?6'cwy/.U nadj ustcdHourly Value
Monitor Hourly Unadjusted Value Status = true
if {Current MHV Max Min Value is not null)
If {{Current MHV Parameter == "H20" AND H2() Missing Data Approach == 'MIN")
OR Current MHV Parameter begins with "02")
if {Current MHV Record \Jn&&)v&tQdiKom\yYa[uQ < Current MHV Max Min
Value)
return result H
else
if {Current MHV Record > Current MHV Max Min
Value)
return result F
Else
return result E
= 08 OR = 09:
If {Current MHV Record \] nadjustcdHourly Value >= 0)
If {Current MHV HBHA Value is not null AND {{Current MHV Parameter == "H20" AND H20 Missing Data
Approach == "MIN") OR Current MHV Parameter begins with "02") AND Current MHV HBHA Value <
Current MHV Record A3 nadjustedHourly Value)
Calculated Unadjusted Value = Current MHV HBHA Value
return result J
else if {Current MHV HBHA Value is not null AND {{Current MHV Parameter == "H20" AND H20 Missing
Data Approach == "MAX") OR Current MHV Parameter does not begin with "02" or "H20") AND Current
MHV HBHA Value > Current A///K/?6'cwy/.U nadj ustcdHourly Value)
Calculated Unadjusted Value = Current MHV HBHA Value
return result G
else
if (Current MHV Record U nadj ustcdHourly Value is not rounded to one decimal place)
return result I
else
Calculated Unadjusted Value = M//K/?6'cwY/.UnadjustcdHourly Value
Monitor Hourly Unadjusted Value Status = true
if {Current MHV Max Min Value is not null)
If {{Current MHV Parameter == "H20" AND H2() Missing Data Approach == 'MIN")
OR Current MHV Parameter begins with "02")
if (CMjrewfM//^./te£w
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
if {Current MHVRecord.UnadjustedHourly Value > Current MHVMax Min
Value)
return result F
Else
return result E
= All Other Codes:
If (Current MHV Record U nadj ustedHourly Value >= 0)
If {Current MHV Parameter in set {"H20", "C02C", "02D", "02W", "C02CSD", "02CSD"} AND Current
MHV Record. U nadj ustcdH oil rly Value > 100)
return result E
else if {Current MHV Record. U nadj ustcdH on rly Value is not rounded to one decimal place)
return result I
else if uadj ustedHourly Value == 0 AND Current MHV Parameter == "C02C" and
Current Hourly Op Record.LoadRange is greater than I,
return result L
else
Calculated Unadjusted Value = Current MHV Record. UnadjustedHourly Value
Monitor Hourly Unadjusted Value Status = true
if {Current MHV Max Min Value is not null)
If {{Current MHV Parameter == "H20" AND H2() Missing Data Approach == 'MIN") OR
Current MHV Parameter begins with "02")
if (Current UnadjustedHourly Value < Current MHV Max Min Value)
return result H
else
if (Current UnadjustedHourly Value > Current MHV Max Min Value)
return result F
Else
return result E
Whether or not there is a result returned:
If {Calculated Unadjusted Value is not null)
case {Current MHV Parameter)
C02C: C02C MHV Calculated Adjusted Value = Calculated Unadjusted Value
02 W: 02 Wet Calculated Adjusted Value = Calculated Unadjusted Value
02D: 02 Dry Calculated Adjusted Value = Calculated Unadjusted Value
H20: H20 MHVCalculated Adjusted Value = Calculated Unadjusted Value
C02CSD: C02C SD Calculated Adjusted Value = Calculated Unadjusted Value
02CSD: 02C SD Calculated Adjusted Value = Calculated Unadjusted Value
Environmental Protection Agency
Page 508 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
A
B
C
D
E
F
H
I
J
K
Response
You reported an MODCCode of 21 in the MHV record for [param], but the
UnadjustedHourly Value does not equal 0.
You reported an MODCCode of [mode] in the MHV record for [param], but the
UnadjustedHourly Value does not equal the maximum potential value reported in the
[comptype] span or default record in your monitoring plan.
You reported an MODCCode of 20 in the MHV record for [param], but the
UnadjustedHourly Value does not equal 200 percent of the FullScaleRange reported in
the C02 span record in your monitoring plan.
You reported an MODCCode of 06 in the MHV record for [param], but the
UnadjustedHourly Value does not equal average of measured hour before and measured
hour after.
The UnadjustedHourly Value reported in the MHV record for [param] is missing or
invalid.
Warning: The UnadjustedHourly Value reported in the MHV record for [param] is in
excess of the maximum value listed in the monitoring plan. Sources are required to
periodically (at least once annually) evaluate the appropriateness of these maximum
values in the monitoring plan and make proper adjustments when necessary.
Adjustments may include the need to update Span and/or Default values. You should
investigate the cause of these exceedances and determine whether adjustments to your
monitoring systems or monitoring plan are necessary.
You reported an MODCCode of [MODC] in the MHV record for [param], but you
reported an UnadjustedHourly Value that is less than the average of the measured hour
before and measured hour after.
Warning: The UnadjustedHourly Value reported in the MHV record for [param] is
lower than the minimum value listed in the monitoring plan. Sources are required to
periodically (at least once annually) evaluate the appropriateness of these minimum
values in the monitoring plan and make proper adjustments when necessary.
Adjustments may include the need to update Default values. You should investigate the
cause of these low values and determine whether adjustments to your monitoring
systems or monitoring plan are necessary.
You reported [fieldname] in the [type] record for [param] that is not rounded to the
appropriate precision for that parameter.
You reported an MODCCode of [MODC] in the MHV record for [param], but you
reported an UnadjustedHourly Value that is greater than the average of the measured
hour before and measured hour after.
You reported an MODCCode of 20 in the MHV record for [param], but the
UnadjustedHourly Value does not equal the default value reported in the 02X default
record in your monitoring plan.
You have reported an UnadjustedHourly Value of 0 in the MHV record for [param], but
the LoadRange is greater than 1. Emissions for [param] should be greater than 0 when
the unit (or stack) is operating at this load level.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Informational Message
Critical Error Level 1
Informational Message
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1
Process/Category:
Emissions Data Evaluation Report —
— C02 Concentration Monitor Hourly Evaluation
2
Process/Category:
Emissions Data Evaluation Report —
— C02C Monitor Hourly Evaluation for Substitute Data
3
Process/Category:
Emissions Data Evaluation Report —
— H20 Monitor Hourly Evaluation
4
Process/Category:
Emissions Data Evaluation Report —
— 02 Dry Monitor Hourly Evaluation
5
Process/Category:
Emissions Data Evaluation Report —
— 02 Wet Monitor Hourly Evaluation
6
Process/Category:
Emissions Data Evaluation Report —
— 02C Monitor Hourly Evaluation for Substitute Data
Environmental Protection Agency
Page 509 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
Check Name:
Related Former Checks:
Applicability:
Description:
Specifications:
Current S02 System BAF = null
Current NOXC System BAF = null
Current FLOW System BAF = null
Continue = true
If (Current MHVParameter == "NOXC")
If (NOx Cone Needed for Nox Mass Calc == false)
Continue == false
If (Continue == true AND Monitor Hourly System Status == true AND Monitor Hourly Preadjusted Value Status == true AND (Current
MHV Record. ModcCode in set {01, 02, 03, 17, 18, 22, 53} OR (Current MHV Record. ModcCode in set {19, 20} AND Current MHV
/?6'cwY/.UnadjustcdHourly Value is not null AND Current MHV Max Min Value is not null)))
If (RATA Status BAF is not null)
case (Current MHV Parameter)
S02C: Current S02 System BAF = RATA Status BAF
NOXC: Current NOXC System BAF = RATA Status BAF
FLOW: Current FLO WSystem BAF = RA TA Status BAF
else
return result A
Results:
Result Response Severity
A The BAF for [ParamCode] MonitoringSystemID [ID] cannot be determined, because Critical Error Level 1
the prior RATA had critical errors or because of a RATA Status error listed on this
report.
Usage:
1 Process/Category:
2 Process/Category:
3 Process/Category:
HOURMHV-21
Determine BAF Value for Monitoring System in MHV Record
Emissions Data Evaluation Report NOXC RATA Status Evaluation
Emissions Data Evaluation Report S02 RATA Status Evaluation
Emissions Data Evaluation Report Stack Flow RATA Status Evaluation
Environmental Protection Agency
Page 510 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURMHV-22
Check Name: Calculate Bias Adjusted Value in MHV Record
Related Former Checks:
Applicability:
Description:
Specifications:
case (Current MHV Parameter)
S02C: CurrentBAF = Current S02 SystemBAF
NOXC: Current BAF = Current NOXC System BAF
FLOW: Current BAF = Current FLOW System BAF
if {Current BAF is not null)
If (Current MHV Parameter == "FLOW")
Tolerance = Lookup Tolerance from Cross-Check Table "Hourly Emissions Tolerances" where
Parameter = Current MHV Parameter AND
UOM = "SCFH"
Calculated Adjusted Value = M//K/?6'cwY/.UnadjustcdHourly Value * Current BAF, and the result to the nearest
1000.
else
Tolerance = Lookup Tolerance from Cross-Check Table "Hourly Emissions Tolerances" where
Parameter = Current MHV Parameter AND
UOM = "PPM"
Calculated Adjusted Value = M//K/?6'cwY/.UnadjustcdHourly Value * Current BAF, and the result to one decimal
place (0.1).
If (Current MHV Record. ModcCode in set {19, 20} AND Calculated Adjusted Value > Current MHV Max Min Value)
case (Current MHV Parameter)
S02C: S02C Calculated Adjusted Value = Current MHV Max Min Value
NOXC: NOXC Calculated Adjusted Value = Current MHV Max Min Value
FLOW: FLOW Calculated Adjusted Value = Current MHV Max Min Value
if (Monitor Hourly Adjusted Value Status == true)
if (Current MHV Record. AdjustedHourlyValue <> Current MHV Max Min Value)
If (Current MHVRecord .ModcCode == 20)
return result A
else
return result C
else
case (Current MHV Parameter)
S02C: S02C Calculated Adjusted Value = Calculated Adjusted Value
NOXC: NOXC Calculated Adjusted Value = Calculated Adjusted Value
FLOW: FLOW Calculated Adjusted Value = Calculated Adjusted Value
if (Monitor Hourly Adjusted Value Status == true)
if ABS(CalculatedAdjusted Value - Current MHV/?6'cwY/.AdjustedHourly Value) > Tolerance
return result B
case (Current MHV Parameter)
S02C: S02C Calculated Adjusted Value = Current MHV Calculated Adjusted Value
NOXC: NOXC Calculated Adjusted Value = Current MHV Calculated Adjusted Value
FLOW: FLOW Calculated Adjusted Value = Current MHV Calculated Adjusted Value
else
Environmental Protection Agency
Page 511 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
A
B
C
Response
You reported an MODCCode of 20 in the MHV record for [param], but the
AdjustedHourly Value does not equal 200 percent of the FullScaleRange reported in the
[comptype] span record in your monitoring plan.
The AdjustedHourly Value reported in the MHV record for [param] is not equal to the
UnadjustedHourly Value times the BAF for the [systype] MonitoringSystemID [ID],
You reported an MODCCode of 19 in the MHV record for [param], but the
AdjustedHourly Value does not equal the DefaultHighRange reported in the [comptype]
span record in your monitoring plan.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report NOXC RATA Status Evaluation
2 Process/Category: Emissions Data Evaluation Report S02 RATA Status Evaluation
3 Process/Category: Emissions Data Evaluation Report Stack Flow RATA Status Evaluation
Environmental Protection Agency
Page 512 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURMHV-23
Check Name: Initialize C02C Hourly Monitor for Substitute Data
Related Former Checks:
Applicability:
Description:
Specifications:
Current MHV Parameter = "C02CSD"
C02C SD Calculated Adjusted Value = null
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report C02C Monitor Hourly Evaluation for Substitute Data
Environmental Protection Agency
Page 513 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURMHV-24
Check Name: Initialize 02C Hourly Monitor for Substitute Data
Related Former Checks:
Applicability:
Description:
Specifications:
Current MHV Parameter = "02CSD"
02C SD Calculated Adjusted Value = null
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report 02C Monitor Hourly Evaluation for Substitute Data
Environmental Protection Agency
Page 514 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOURMHV-26
Check Name:
Determine if MHV Record Needs QA Status Evaluation
Related Former Checks:
Applicability:
Description:
Specifications:
Set LinearityStatusRequired = false.
Set Current Linearity Status = null.
Set RATAStatusRequired = false.
Set Current RATA Status = null.
Set RA TA Status BAF = null.
Set DailyCalStatusRequired = false
Set Current Daily Cal Status = null.
Set F2L Status Required = false.
Set Daily Int Status Required = false
Set Leak Status Required = false
Set QaStatusComponentld = CurrentMHVRecord. Co mpolie n11d
Set QaStatusComponentldentifier = CurrentMH VRecord. C o m po lie n 11 dc n t i fi c r
Set QaStatusComponentTypeCode = CurrentMH VRecord.CompolientTypcCodc
Set QaStatusSystemDesignationCode = CurrentMH VRecord. Sy s tc 111D c s i g na t i o 11C o dc
Set QaStatusSystemld = CurrentMHVRecord .Syslcm I d
Set QaStatusSystemldentifier = CurrentMH VRecord. Sy stem I dc nti fie r
Set QaStatusSystemTypeCode = CurrentMH VRecord. Sy s t c niTy pc C 0 dc
if (Monitor Hourly Mode Status == true AND
(CurrentMHVRecord.IVI0dcC0dc in set {01, 02, 03, 17, 18, 21, 22, 53} OR
(CurrentMHVRecord.IVI0dcC0dc in set {19, 20} AND CurrentMHVRecord UnadjustcdHourly Value is not null AND
Current MHV Max Min Value is not null)))
if (Monitor HourlyComponentStatus = true AND CurrentMH VRecord. C 0111 po 11c 1111D is not null AND CurrentMHVParameter in
set {S02C, NOXC, C02C, 02D, 02W})
Set LinearityStatusRequired = true.
Set DailyCalStatusRequired = true.
if (Monitor HourlyComponentStatus = taic AND CurrentMH VRecord.Componcnl\D is not null AND CurrentMHVParameter in
set {FLOW})
Set DailyCalStatusRequired = true.
Set Daily Int Status Required = true.
If SampleAcquistionlVIctliodCd = "DP"
Set Leak Status Required = true.
if (MonitorHourlySystemStatus = true AND CurrentMH VRecord Mo\\\{o ri ngSy stc 1111D is not null AND
CurrentMHVRecord SystcmTypcCodc is in {S02, NOXC, FLOW, H20M})
Set RATAStatusRequired = true.
Set CurrentHourlyRecordforRATAStatus = CurrentMHVRecord.
if CurrentMH VRecord. Sy stc mTy pcCodc is equal to 'FLOW',
Set F2L Status Required = true.
Environmental Protection Agency
Page 515 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
else if ((CO2 Cone Checks Neededfor Heat Input == true AND CurrentMHVParameter == "C02C") OR (02 Wet Checks
Needed for Heat Input == true AND CurrentMHVParameter == "02 W") OR (()2 Dry Checks Needed for Heat Input == true
AND CurrentMHVParameter == "02D"))
Set C02RATARequired = true.
if (RATA Status Required == false AND Current MHVParameter in {S02C, NOXC, FLOW})
case (Current MHV Parameter)
S02C: S02C Calculated Adjusted Value = Current MHV Calculated Adjusted Value
NOXC: NOXC Calculated Adjusted Value = Current MHV Calculated Adjusted Value
FLOW: FLOW Calculated Adjusted Value = Current MHV Calculated Adjusted Value
if (LinearifyStatusRequired == true OR DailyCalStatusRequired == true)
Set DualRangeStatus = false.
Set CurrentAnalyzerRangeUsed = null.
Set ApplicableSystemlDs = null.
Set HighRangeComponentID = null.
Set LowRangeComponentID = null.
if (CurrentMHVParameter == "FLOW")
Set ApplicableComponentll) = Current MHV Record.Components)
else
Set ApplicableComponentID = null.
Locate a record in AnalyzerRangeRecordsByHourLocation for the hour and location where the ComponentID is equal to
the CurrentMHVRecord. ComponentID.
if (AnalyzerRangeRecordsByHourLocation is not found OR if more than one AnalyzerRangeRecordsByHourLocation is
found)
set Linearity Status Required == false
set DailyCalStatusRequired = false
return result A
else
if (AnalyzerRangeRecordsByHourLocation.DualRangelndicator =1)
Set DualRangeStatus = true.
if (Analyzer Range Record.AnalyzerRangeCode = "A")
Locate the record in MonitorSpanRecordsByHourLocation for the hour and location where the
ComponentTypeCode is equal to the CurrentMHVRecord ComponcntTypcCode and the
SpanScaleCode is equal to "L".
if (MonitorSpanRecordsByHourLocation is not found OR if more than one
MonitorSpanRecordsByHourLocation is found OR if the
MonitorSpanRecordsByHourLocation ScaleTransitionPoint is null or <= 0)
set Linearity Status Required == false
set DailyCalStatusRequired = false
return result B
else if (MonitorSpanRecordsByHourLocation is found AND
Environmental Protection Agency
Page 516 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
C.'M/7*6'M?M//K/?6'eMY/.UnadjustcdHourly Value >
MonitorSpanRecordsByHourLocation. ScaleTransitionPoint AND
CurrentMHVRecord.ModcCode <> "18")
Set CurrentAnalyzerRangeUsed = "H".
Set HighRangeComponentID = CurrentMHVRecord. Component ID.
Set LowRangeComponentID = CurrentMHVRecord. Component ID.
else
Set CurrentAnalyzerRangeUsed = "L".
Set HighRangeComponentID = CurrentMHVRecord.Componcnl ID.
Set LowRangeComponentID = CurrentMHVRecord.Componcnl ID.
Set CurrentAnalyzerRangeUsed =
AnalyzerRangeRecordsByHourLocation. AnalyzerRangeCode.
if (AnalyzerRangeRecordsByHourLocation.Amh/crRdngcCodc = "H")
Locate a record in AnalyzerRangeRecordsByHourLocation for the hour and location
where the ComponentTypeCode is equal to the
CurrentMHVRecord.ComponcntTypcCodc and the AnalyzerRangeCode is equal to "L"
AND the ComponentSerialNumber is equal to the
CurrentMHVRecord.ComponcnlScmWumbcr (removing the phrases "HIGH", "HI",
"LOW", and "LO").
if (AnalyzerRangeRecordsByHourLocation is not found OR if more than one
AnalyzerRangeRecordsByHourLocation is found)
set Linearity Status Required == false
set DailyCalStatusRequired = false
return result C
else If (AnalyzerRangeRecordsByHourLocation is found)
Set HighRangeComponentID = CurrentMHVRecord. Component ID.
Set LowRangeComponentID =
AnalyzerRangeRecordsByHourLocation. Component ID.
else if {CurrentMHVRecord. AnalyzerRangeCode = "L")
Locate a record in AnalyzerRangeRecordsByHourLocation for the
CurrentMHVRecord. Hour where the ComponentTypeCode is equal to the
CurrentMHVRecord. ComponentTypeCode and the AnalyzerRangeCode is equal to "H"
AND the ComponentSerialNumber is equal to the
CurrentMHVRecord.ComponentSerialNumber (removing the phrases "HIGH", "HI",
"LOW", and "LO").
if (AnalyzerRangeRecordsByHourLocation is not found OR if more than one
AnalyzerRangeRecordsByHourLocation is found)
set Linearity Status Required == false
set DailyCalStatusRequired = false
return result C
else If (AnalyzerRangeRecordsByHourLocation is found)
Environmental Protection Agency
Page 517 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Set LowRangeComponentID = CurrentMHVRecord. Component ID.
Set HighRangeComponentID =
AnalyzerRangeRecordsByHourLocation. Component ID.
else
Set CurrentAnalyzerRangeUsed = AnalyzerRangeRecordsByHourLocation. AnalyzerRangeCode.
if (CurrentAnalyzerRangeUsed = "H")
Set HighRangeComponentID = CurrentMHVRecord.Componcnl ID.
else
Set LowRangeComponentID = CurrentMHVRecord. Co mpo lie lit ID.
if (CurrentAnalyzerRangeUsed = "H")
Set ApplicableComponentID = HighRangeComponentID.
else
Set ApplicableComponentID = LowRangeComponentID.
For each record in MonitorSystemComponentRecordsByHourLocation where the ComponentID is equal to the
ApplicableComponentID
Append MonitorSystemComponentRecordsByHourLocation.SystemlD to ApplicableSystemlDs.
if (MonitorSystemComponentRecordsByHourLocation is not found)
set Linearity Status Required == false
set DailyCalStatusRequired = false
return result D
Results:
Result
A
B
C
D
Response
You did not report one (and only one) valid Analyzer Range record in your monitoring
plan for ComponentID [COMPID] for this hour. The QA Status of the linearity and/or
daily calibration tests for this component will not be evaluated.
You reported that ComponentID [COMPID] is a dual-range analyzer, but you did not
report one (and only one) active low-scale [COMPTYPE] span record with a valid
ScaleTransitionPoint in your monitoring plan for this hour. The QA Status of the
linearity and/or daily calibration tests for this component will not be evaluated.
You reported that ComponentID [COMPID] is a dual-range analyzer, but the program
could not identify the alternate range component in your monitoring plan. The QA
Status of the linearity and/or daily calibration tests for this component will not be
evaluated.
You did not report any System Component records for ComponentID [compid] in your
monitoring plan for the hour. The QA Status of the linearity and/or daily calibration
tests for this component will not be evaluated.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 518 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Usage:
1 Process/Category: Emissions Data Evaluation Report
2 Process/Category: Emissions Data Evaluation Report
3 Process/Category: Emissions Data Evaluation Report
4 Process/Category: Emissions Data Evaluation Report
5 Process/Category: Emissions Data Evaluation Report
6 Process/Category: Emissions Data Evaluation Report
7 Process/Category: Emissions Data Evaluation Report
C02 Concentration Monitor Hourly Evaluation
FLOW Monitor Hourly Evaluation
H20 Monitor Hourly Evaluation
NOx Concentration Monitor Hourly Evaluation
02 Dry Monitor Hourly Evaluation
02 Wet Monitor Hourly Evaluation
S02 Monitor Hourly Evaluation
Environmental Protection Agency
Page 519 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOURMHV-27
Check Name: Determine MHV Measure Code
Related Former Checks:
Applicability:
Description:
Specifications:
If {Current MHV Parameter == "C02CSD")
Set Monitor Measure Code Array for "C02C" to "SUB"
else If {Current MHV Parameter == "02CSD")
Set Monitor Measure Code Array for "02D" to "SUB"
Set Monitor Measure Code Array for "02 W" to "SUB"
else if {Current MHV Parameter in set { S02C, NOXC, C02C, 02D, 02 W, FLOW, H20 } AND Monitor Measure Code Array for the
Current MHV Parameter is null)
If {Current MHV Record. ModcCode in set {01, 02, 03, 04, 05, 16, 17, 19, 20, 21, 22, 53, 54})
Set Monitor Measure Code Array for the Current MHV Parameter to "MEASURE"
else if {Current MHV Record.ModcCode in set {06, 07, 08, 09, 10, 11, 12, 13, 15, 23, 24, 55})
Set Monitor Measure Code Array for the Current MHV Parameter to "SUB"
else if {Current MHV Record. ModcCode == "18"
Set Monitor Measure Code Array for the Current MHV Parameter to "MEASSUB"
Results:
Result Response Severity
Usage:
1
Process/Category:
Emissions Data Evaluation Report —
— C02 Concentration Monitor Hourly Evaluation
2
Process/Category:
Emissions Data Evaluation Report —
— C02C Monitor Hourly Evaluation for Substitute Data
3
Process/Category:
Emissions Data Evaluation Report —
— FLOW Monitor Hourly Evaluation
4
Process/Category:
Emissions Data Evaluation Report —
— H20 Monitor Hourly Evaluation
5
Process/Category:
Emissions Data Evaluation Report —
— NOx Concentration Monitor Hourly Evaluation
6
Process/Category:
Emissions Data Evaluation Report —
— 02 Dry Monitor Hourly Evaluation
7
Process/Category:
Emissions Data Evaluation Report —
— 02 Wet Monitor Hourly Evaluation
8
Process/Category:
Emissions Data Evaluation Report —
— 02C Monitor Hourly Evaluation for Substitute Data
9
Process/Category:
Emissions Data Evaluation Report —
— S02 Monitor Hourly Evaluation
Environmental Protection Agency
Page 520 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Category:
Hourly Operating Data
Environmental Protection Agency
Page 521 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOUROP-1
Check Name: Validate Single Operating Data record for hour
Related Former Checks:
Applicability:
Description:
Specifications:
Current Hourly Op Record = null
Unit Hourly Operational Status = false
Current Operating Time = null
Hourly Extraneous Fields = null
Count all HourlyOperatingData records with current MonitoringLocationID where
BeginHour = Current Hour AND
BeginDate = Current Date
If count == 0
Derived Hourly Checks Needed = false
if {Current Month is not April OR Annual Reporting Requirement == true)
If (Current Entity Type == "Unit" OR LME HI Method is null)
If (Reporting Period Operating == false AND Legacy Data Evaluation == true)
return result E
else
Locate Monitor Method records where the BeginDate/BeginHour is on or before the Current Date and
Hour, and the EndDate/EndHour is null or is on or after the Current Date and Hour.
If found
return result A
else if count > 1
if {Current Month is not April OR Annual Reporting Requirement == true)
Rpt Period C02 Mass Reported Accumulator Array for the location = -1
Rpt Period C02 Mass Calculated Accumulator Array for the location =-1
Rpt Period HI Reported Accumulator Array for the location =-1
Rpt Period HI Calculated Accumulator Array for the location = -1
Rpt Period NOx Rate Reported Accumulator Array for the location = -1
Rpt Period NOx Rate Calculated Accumulator Array for the location = -1
Rpt Period S02 Mass Reported Accumulator Array for the location = -1
Rpt Period S02 Mass Calculated Accumulator Array for the location = -1
Rpt Period NOx Mass Reported Accumulator Array for the location = -1
Rpt Period NOx Mass Calculated Accumulator Array for the location = -1
Rpt Period Op Time Accumulator Array for the location = -1
Rpt Period Op Hours Accumulator Array for the location = -1
Daily Op Time Accumulator Array for the location = -1
Derived Hourly Checks Needed = false
return result B
else if {Current Entity Type <> "Unit" AND LME HI Method is not null)
Derived Hourly Checks Needed = false
return result D
else
Current Hourly Op Record = Unique HourlyOperatingData record
Current Operating Time = Current Hourly Op Record.OperatingTime
If {First Day of Operation is null)
Environmental Protection Agency
Page 522 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
First Day of Operation = Current Hourly Op Record. Date
First Hour of Operation = Current Hourly Op Record.Hour
if Current Operating Time >1.0 OR Current Operating Time < 0.0
Derived Hourly Checks Needed = false
if {Current Month is not April OR Annual Reporting Requirement == true)
Rpt Period Op Time Accumulator Array for the location = -1
Rpt Period Op Hours Accumulator Array for the location = -1
Daily Op Time Accumulator Array for the location = -1
if {Current Entity Type= "Unit")
Unit OpTime Accumulator = -1
else
Stack OpTime Accumulator = -1
return result C
else
Derived Hourly Checks Needed = true
if Current Operating Time > 0.0
Unit Hourly Operational Status = true
if {Operating Date Array entry for this location does not contain Current Hourly Op Record.Date)
Add Current Hourly Op Record.Date to Operating Date Array entry for this location
if {Current Month is not April OR Annual Reporting Requirement == true)
if {Rpt Period Op Hours Accumulator Array for this location is not null)
if {Rpt Period Op Hours Accumulator Array for this location >= 0)
Rpt Period Op Hours Accumulator Array for this location = Rpt Period Op Hours
Accumulator + 1
else
Rpt Period Op Hours Accumulator Array for this location = 1
if {Rpt Period Op Time Accumulator Array for this location is not null)
if {Rpt Period Op Time Accumulator Array for this location >= 0)
Rpt Period Op Time Accumulator Array for this location = Rpt Period Op Time
Accumulator + Current Hourly Op Record.Opcrat ingTime
else
Rpt Period Op Time Accumulator Array for this location = Current Hourly Op
Record. OperatingT ime
If {Current Month is April)
if {April Op Hours Accumulator Array for this location is not null)
April Op Hours Accumulator Array for this location = April Op Hours Accumulator + 1
else
April Op Hours Accumulator Array for this location = 1
if {April Op Time Accumulator Array for this location is not null)
April Op Time Accumulator Array for this location = April Op Time Accumulator +
Current Hourly Op Record. O pc rat i ngT ime
else
April Op Time Accumulator Array for this location = Current Hourly Op
Record. OperatingT ime
if {Daily Op Time Accumulator Array for this location is not null)
if {Daily Op Time Accumulator Array for this location >= 0)
Daily Op Time Accumulator Array for this location = Daily Op Time Accumulator + Current
Hourly Op Record.OperatingTime
Environmental Protection Agency
Page 523 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
else
Daily Op Time Accumulator Array for this location = Current Hourly Op Record. Opcra t i ngTi mc
if (Last Day of Operation Array for the location is null OR is not equal to Current Date)
Last Day of Operation Array for the location = Current Date
if (Rpt Period Op Days Accumulator Array for this location is not null)
if (Rpt Period Op Days Accumulator Array for this location >= 0)
Rpt Period Op Days Accumulator Array for this location = Rpt Period Op Days
Accumulator + 1
else
Rpt Period Op Days Accumulator Array for this location = 1
If (Current Month is April)
if (April Op Days Accumulator Array for this location is not null)
April Op Days Accumulator Array for this location = April Op Days Accumulator + 1
else
April Op Days Accumulator Array for this location = 1
if (Current Entity Type= "Unit")
if (Unit OpTime Accumulator >= 0)
Unit OpTime Accumulator = Unit OpTime Accumulator + Current Hourly Op
Record. OperatingT ime
if Current Hourly Op ./tecon/.OperatingTime > Max Unit OpTime
Max Unit OpTime = Current Hourly Op Record.Opc rat i ngT i me
else if (Current Entity Type == "CS" OR Current Entity Type == 'MS")
if (Stack OpTime Accumulator >= 0)
Stack OpTime Accumulator = Stack OpTime Accumulator + Current Hourly Op
Record. OperatingT ime
if Current Hourly Op Ttecon/.OperatingTime > Max Stack OpTime
Max Stack OpTime = Current Hourly Op Ttecon/.OperatingTime
Results:
Result
A
B
C
D
Response Severity
You did not report an Hourly Operating record for the hour. Critical Error Level 1
You reported more than one Hourly Operating records for the hour. There will be no Critical Error Level 1
further evaluation of the reported emissions data for this hour.
The OperatingTime reported in the Hourly Operating record is invalid. This value must Critical Error Level 1
be between 0 and 1. There will be no further evaluation of the reported emissions data
for this hour.
You reported an invalid Hourly Operating record. Only the units in an LME
monitoring configuration should report this record. There will be no further evaluation
of the reported emissions data for this hour.
You did not report an Hourly Operating record for the hour. Although this was
acceptable for legacy data during a non-operating quarter, it is not allowed in ECMPS.
Critical Error Level 1
Fatal
Usage:
1
Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Environmental Protection Agency
Page 524 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOUROP-2
Check Name: Count Flow, 02, and Heat Input records
Related Former Checks:
Applicability:
Description:
Specifications:
Flow Monitor Hourly Count = count of MonitorHourlyValueData records with parameter FLOW where
Current Date = MonitorHourlyValueData.Date and
Current Hour = MonitorHourlyValueData.Hour
02 Wet Monitor Hourly Count = count of MonitorHourlyValueData records with ParameterCode = "02C" AND MoistureBasis = "W"
where
Current Date = MonitorHourlyValueData.Date and
Current Hour = MonitorHourlyValueData.Hour
02 Dry Monitor Hourly Count = count of MonitorHourlyValueData records with ParameterCode = "02C" AND MoistureBasis = "D"
where
Current Date = MonitorHourlyValueData.Date and
Current Hour = MonitorHourlyValueData.Hour
02 Null Monitor Hourly Count = count of MonitorHourlyValueData records with ParameterCode = "02C" AND MoistureBasis is NULL
where
Current Date = MonitorHourlyValueData.Date and
Current Hour = MonitorHourlyValueData.Hour
if 02 Null Monitor Hourly Count == 1
Current 02 Null Monitor Hourly Record = the single matching record
Heat Input Derived Hourly Count = count of DerivedHourly ValueData records with ParameterCode equal to "HI" where
Current Date = DerivedHourly ValueData.Date and
Current Hour = DerivedHourly ValueData.Hour
// 02 Needed To Support Heat Input = false
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Environmental Protection Agency
Page 525 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOUROP-3
Check Name: Initialize Location Variables for the Hour
Related Former Checks:
Applicability:
Description:
Specifications:
Current Unit Is Peaking = false
Current UnitlsARP = false
Special Fuel Burned = false
FC Factor Needed = false
FI) Factor Needed = false
FW Factor Needed = false
Moisture Needed = false
H20 Missing Data Approach = null
Flow Monitor Hourly Checks Needed = false
Current MHV Parameter = null
Current DHVParameter = null
Current DHVRecord Valid = false
Current DHV Record = null
Current DHV Method = null
Current DHV System Type = null
Current DHVHBHA Value = null
CO2 Cone Checks Neededfor C02 Mass Calc = false
CO2 Cone Checks Needed for Heat Input = false
CO2 Diluent Checks Neededfor NOx Rate Calc = false
02 Dry Checks Needed for Heat Input = false
02 Dry Checks Neededfor NOx Rate Calc = false
02 Wet Checks Neededfor Heat Input = false
02 Wet Checks Neededfor NOx Rate Calc = false
CO2 Diluent Needed for MA TS = false
02 Dry Needed for MA TS = false
02 Wet Needed for MA TS = false
Linearity Status Required = false
AppendixEStatusRequired = false
RATAStatusRequired = false
Current RATA Status = null
CurrentHourlyRecordforRATAStatus = null
RA TAStatusBAF = null
Daily Cal Status Required = false
CO2 RA TA Required = false
HI Measure Code = null.
NOXR Measure Code = null.
F2L Status Required = false
Daily Int Status Required = false
Leak Status Required = false
C02CMHVMODC = null
H20DHVMODC = null
H20MHVMODC = null
02 DryMODC = null
02 WetMODC = null
If the StackPipelD of the monitoring location begins with "CS",
set Current Entity Type = "CS"
else if the StackPipelD of the monitoring location begins with "CP",
Environmental Protection Agency
Page 526 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
set Current Entity Type = "CP"
else if the StackPipelD of the monitoring location begins with "MS",
set Current Entity Type = "MS"
else if the StackPipelD of the monitoring location begins with "MP",
set Current Entity Type = "MP"
else
set Current Entity Type = "Unit"
if Current Entity Type = "Unit"
Mon Qual Record Count = Find Monitor Qualification Records by Hour where
MonitoringLocationld = Current Location
Mon Qual Record. QualTypecode == "PK" OR Mon Qual RecordQualTypecode == "SK"
if Mon Qual Record Count > 0
Current Unit Is Peaking = true
else if Current Entity Type = "CP"
find all entries in UnitStackConfiguration table where
UnitStackConfiguration.StackPipeId = the StackPipeld for this pipe
for each matching record
set Assoc Unit = UnitStackConfiguration.Unitld
Mon Qual Record Count = Find MonitorQualification Records by Hour where
MonitoringLocationld = Assoc Unit
Mon Qual Record. QualTypecode == "PK" OR Mon Qual Record. QualTypecode == "SK"
if Mon Qual Record Count is not null
Current Unit Is Peaking = true
locate records in the UnitProgram Table where
either (a) for a unit there is a record with the location identifier for that unit, OR
(b) for a non-unit there is a record with the location identifier for a unit associated with that entity
if any records from UnitProgram table meeting these conditions exist and within those records:
PRG CD = "ARP", CLASS <> "NA", EndDate is on or after the Current Operating Date
and either a) the EmissionsRecordingDate is not null and is on or prior to the Current Operating Date or b) the
EmissionsRecordingDate is null and the UnitMonitorCertBeginDate is not null and is on or prior to the Current Operating Date.
Current Unit Is ARP = true
Set EarliestLocationReportDate = CurrentMonitorPlanLocationRecord.EarliestReportDate
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Environmental Protection Agency
Page 527 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOUROP-4
Check Name: Verily S02 Monitor Method Active During Current Hour
Related Former Checks:
Applicability:
Description:
Specifications:
If (DerivedHourly Checks Needed)
S02 Monitor Method Record = null
SO2 CEM Method Active For Hour = false
SO2 App D Method Active For Hour = false
SO2 F23 Method Active For Hour = false
SO2 Method Code = null
S02 Fuel Specific Missing Data = false
SO2 Bypass Code = null
S02 Method Count = Active records in MonitoringMethodData for the location where
ParameterCode = "S02" or "S02M"
if {SO2 Method Count >1)
return result A
else if SO2 Method Count == 1
SO2 Monitor Method Record = the single matched record
SO2 Method Code = S02 Monitor Method Record. MethodCode
if (LME HI Method is not null AND S02 Method Code <> "LME")
return result B
else
if (S02 Monitor Method Record. SubDataCodc begins with "FSP75")
SO2 Fuel Specific Missing Data = true
SO2 Bypass Code = S02 Monitor Method Record. Bypass ApproachCodc
Expected Summary Value S02 Array for this location = true
if (S02 Monitor Method Record. MethodCode == "CEM")
SO 2 CEM Method Active For Hour = true
else if S02 Monitor Method Record.MethodCode == "F23")
SO 2 F23 Method Active For Hour = true
else if (S02 Monitor Method Record. MethodCode == "AD")
S02 App D Method Active For Hour = true
Results:
Result Response Severity
A You have reported more than one active S02 Method record in your monitoring plan Critical Error Level 1
for this hour.
B You reported an invalid [param] method for a location that is part of a configuration of Critical Error Level 1
LME units.
Environmental Protection Agency
Page 528 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
Usage:
1 Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Environmental Protection Agency
Page 529 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOUROP-5
Check Name: Determine H20 Method
Related Former Checks:
Applicability:
Description:
Specifications:
if Derived Hourly Checks Needed
H20 Method Code = null
H20 Default Value = null
H20 Default Max Value = null
H20 Default Mitt Value = null
Current Hourly H20 Table Reference = null
H20 Fuel Specific Missing Data = false
H20 Reported Value = null
H20 Method Count = Active records in MonitoringMethodData for the location where
ParameterCode = "H20"
H20 Derived Hourly Count = count of DerivedHourly ValueData where ParameterCode = "H20" for current hour
H20 Monitor Hourly Count = count of MonitorHourly ValueData where ParameterCode = "H20" for current hour
if (H20 Method Count > 2
return result A
else if (H20 Method Count == 2)
If (H20 Derived Hourly Count + H20 Monitor Hourly Count > 0)
If (H20 Derived Hourly Count == 1 AND H20 Monitor Hourly Count == 0 AND the MethodCode in one of the
matched records is equal to "MWD")
Current Hourly H20 Table Reference = DerivedHourly ValueData where ParameterCode = "H20"
H20 Reported Value = Current Hourly H20 Table Reference. k&\ ustedHourly Value
H20 Method Code = "MWD"
else if (H20 Derived Hourly Count == 0 AND H20 Monitor Hourly Count == 1 AND the MethodCode in one
(but not both) of the matched records is equal to "MTB" or "MMS")
Current Hourly H20 Table Reference = MonitorHourlyValueData where ParameterCode = "H20"
H20 Reported Value = Current Hourly H20 Table /fe/mJwce.UnadjustcdHourlv Value
if the MethodCode in the matched record == 'MMS"
H20 Method Code = 'MMS"
else
H20 Method Code = 'MTB"
else
return result A
else if H20 Method Count == 1
H20 Monitor Method Record = the single matched record
H20 Method Code = H20 Monitor Method Record. MethodCode
if (H20 Monitor Method Record. SlibDataCode begins with "FSP75")
H20 Fuel Specific Missing Data = true
if (H20 Method Code == MDF')
H20 Default Record Count = count active MonitoringDefaultData Records for the location where ParameterCd =
'H20'
if (H20 Default Record Count == 0)
return result B
else if (H20 Default Record Count >1)
if (H20 Derived Hourly Count == 1)
Current Hourly H20 Table Reference = DerivedHourly ValueData where ParameterCode =
Environmental Protection Agency
Page 530 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
"H20'
H20 Default Max Value = Highest DefaultValue field from active MonitoringDefaultData record for
location where ParameterCd = 'H20'
H20 Default Min Value = Lowest DefaultValue field from active MonitoringDefaultData record for
location where ParameterCd = 'H20'
If (H20 Default Max Value <= 0 OR H20 Default Min Value <= 0 OR H20 Default Max Value >=
100 OR H20 Default Min Value >= 100)
return result C
H20 Default Value = DefaultValue field from active MonitoringDefaultData record for location where
ParameterCd = 'H20'
If (H2() Default Value <= 0 OR H20 Default Value >= 100)
return result C
else if (H20 Method Code == "MWD")
if (H20 Derived Hourly Count == 1)
Current Hourly H20 Table Reference = DerivedHourlyValueData where ParameterCode = "H20"
H20 Reported Value = Current Hourly H20 Table Reference.hdL)ustQdRom\y Value
else if (H2() Method Code == "MMS" OR H20 Method Code == "MTB")
if (H20 Monitor Hourly Count == 1)
Current Hourly H20 Table Reference = MonitorHourly ValueData where ParameterCode = "H20"
H20 Reported Value = Current Hourly H20 Table /?e/67*6'rtC6'.UnadjustcdHourly Value
else
Results:
Result
A
Response
You have reported more than one active H20 Method record in your monitoring plan
for this hour.
You reported an H20 MethodCode of MDF, but you did not report an active H20
default record in your monitoring plan for the hour.
The DefaultValue reported in the active H20 default record in your monitoring plan is
invalid.
Severity
Critical Error Level 1
B
Critical Error Level 1
C
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Environmental Protection Agency
Page 531 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOUROP-6
Check Name:
Verily NOx Rate Monitor Method
Related Former Checks:
Applicability:
Description:
Specifications:
If (DerivedHourly Checks Needed)
NOx Rate Bypass Code = null
NOx Rate Fuel Specific Missing Data = false
Current NOx Rate Monitor Method Record = null
Current NOx Rate Method Code = null
NOx Rate Method Count = Active records in MonitoringMethodData for the location where
ParameterCode = "NOXR"
if (NOx Rate Method Count > 1)
return result A
else if NOx Rate Method Count == 1
if (LME HI Method is not null)
Current NOx Rate Monitor Method Record = the single matched record
Current NOx Rate Method Code = Current NOx Rate Monitor Method McthodCodc
NOx Rate Bypass Code = Current NOx Rate Monitor Method Record .Bypass ApproachCode
if (Current NOx Rate Monitor Method Record. SubDataCode begins with "FSP75")
NOx Rate Fuel Specific Missing Data = true
If (Current Unit is ARP == true)
Expected Summary Value NOx Rate Array for this location = true
return result B
else
Results:
Result
A
You reported more than one active NOXR Method record in your monitoring plan for Critical Error Level 1
this hour.
You reported a [param] method, which is not valid for a location that is part of a Critical Error Level 1
configuration of LME units.
Response
Severity
B
Usage:
1 Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Environmental Protection Agency
Page 532 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOUROP-7
Check Name:
Verily NOx Mass Monitor Method Record
Related Former Checks:
Applicability:
Description:
Specifications:
If (DerivedHourly Checks Needed)
Current NOx Mass Monitor Method Record = null
NOx Mass Method Active For Hour = false
NOx Mass Monitor Method Code = null
NOx Mass Bypass Code = null
NOx Mass Fuel Specific Missing Data = false
NOx Mass Method Count = Active records in MonitoringMethodData for the location where
ParameterCode = "NOX" or "NOXM"
if (NOx Mass Method Count > 1)
return result A
else if NOx Mass Method Count == 1
Current NOx Mass Monitor Method Record = the single matched record
NOx Mass Monitor Method Code = NOx Mass Monitor Method Record. MethodCode
if (LME HI Method is not null AND NOx Mass Monitor Method Code <> "LME")
return result B
else
Expected Summary Value NOx Mass Array for this location = true
NOx Mass Bypass Code = Current NOx Mass Monitor Method Record. By pass ApproachCode
if (Current NOx Mass Monitor Method Record. SubDataCode begins with "FSP75")
NOx Mass Fuel Specific Missing Data = true
if (NOx Mass Monitor Method Record. MethodCode == "CEM" OR
NOx Mass Monitor Method Record.MethodCode == "NOXR" OR
NOx Mass Monitor Method Record.MethodCode == "CEMNOXR" OR
NOx Mass Monitor Method Record.MethodCode == "AMS")
NOx Mass Method Active For Hour = true
If (NOx Mass Monitor Method Code == "LME" AND Current Unit is ARP == true)
Expected Summary Value NOx Rate Array for this location = true
Results:
Result
A
Response
You reported more than one active NOX Method record in your monitoring plan for
this hour.
Severity
Critical Error Level 1
B
You reported an invalid [param] method for a location that is part of a configuration of Critical Error Level 1
LME units.
Environmental Protection Agency
Page 533 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
Usage:
1 Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Environmental Protection Agency
Page 534 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOUROP-8
Check Name:
Verily C02 Method Active During Current Hour
Related Former Checks:
Applicability:
Description:
Specifications:
If (DerivedHourly Checks Needed)
C02 Monitor Method Record = null
CO 2 CEM Method Active For Hour = false
CO 2 App D Method Active For Hour = false
CO2 Fuel Specific Missing Data = false
CO2 Method Code = null
// AD and CEMs are possible method codes
CO2 Method Count = Active records in MonitoringMethodData for the location where
ParameterCode = "C02" or "C02M"
if (CO2 Method Count > 1)
return result A
else if C02 Method Count == 1
CO2 Monitor Method Record = the single matched record
CO 2 Method Code = C02 Monitor Method Record .MethodCode
if (Current C02 Monitor Method Record. SubDataCode begins with "FSP75")
CO2 Fuel Specific Missing Data = true
if {C02 Monitor Method Record. MethodCode == "CEM")
CO2 CEM Method Active For Hour = true
else if (C02 Monitor MethodRecord.MeihodCode == "AD")
CO 2 App D Method Active For Hour = true
Expected Summary Value C02 Array for this location = true
if (LME HI Method is not null and CO 2 Method Code is not equal to "LME")
return result B
else
Results:
Result
A
Response
You have reported more than one active C02 Method record in your monitoring plan
for this hour.
You reported an invalid [param] method for a location that is part of a configuration of
LME units.
Severity
Critical Error Level 1
B
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Environmental Protection Agency
Page 535 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOUROP-9
Check Name:
Verily Heat Input Method Active During Current hour
Related Former Checks:
Applicability:
Description:
Specifications:
If (DerivedHourly Checks Needed)
Heat Input Monitor Method Record = null
Heat Input Fuel Specific Missing Data = false
Heat Input Method Code= null
Heat Input CEM Method Active For Hour = false
Heat Input App D Method Active For Hour = false
Heat Input Method Count = Active records in MonitoringMethodData for the location where
ParameterCode begins with "HF
if (Heat Input Method Count > 1)
return result A
else if (LME HI Method is not null AND (Heat Input Method Count == 0 OR ParameterCode in the matched record is not equal
to "HIT"))
return result B
else if (Heat Input Method Count == 1)
Heat Input Monitor Method Record = the single matched record
Heat Input Method Code = Heat Input Monitor Method McthodCodc
LME HI Substitute Data Code = Heat Input Monitor Method Record. SubstituteDataCode
if (Heat Input Monitor Method Ttecon/.SubDataCode begins with "FSP75")
Heat Input Fuel Specific Missing Data = true
if (Heat Input Monitor Method Record.MQthodCodQ == "CEM")
Heat Input CEM Method Active For Hour = true
else if (Heat Input Monitor Method Record. McthodCodc == "AD" OR Heat Input Monitor Method
Record. McthodCodc == "ADCALC")
Heat Input App D Method Active For Hour = true
If (Heat Input Monitor Method Record.MethodCode <> "EXP")
Expected Summary Value HI Array for this location = true
if (Heat Input Monitor Method Record ParameterCode == "HI")
Apportionment HI Method Array for this location = Heat Input Method Code
Results:
Result
A
Response
You have reported more than one active HI Method record in your monitoring plan for
this hour.
You did not report an HIT Method record for this location in your monitoring plan,
which is required for all locations that are part of a configuration of LME units.
Severity
Critical Error Level 1
B
Critical Error Level 1
Environmental Protection Agency
Page 536 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
Usage:
1 Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Environmental Protection Agency
Page 537 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOUROP-17
Check Name: Verily Single S02 Derived Hourly Data Record
Related Former Checks:
Applicability:
Description:
Specifications:
If (Derived Hourly Checks Needed == true)
SO2 Derived Checks Needed = false
S02MDerived Checks Needed = false
Current S02 Derived Hourly Record = null
F23 Default Max Value = null
F23 Default Min Value = null
F23 Default Value = null
S02 Derived Hourly Count = count of DerivedHourly ValueData records with ParameterCode = "S02" or "S02M" where
Current Date = DerivedHourly ValueData.Date and
Current Hour = DerivedHourly ValueData.Hour
If Current Hourly Op Ttecon/.OperatingTime > 0
If (S()2 Derived Hourly Count == 0 AND SO2 Method Code is not null)
If (S02 Method Code == "AD")
If (Hourly Fuel Flow Count for Gas + Hourly Fuel Flow Count for Oil > 0)
return result A
else
return result A
Else if (S()2 Derived Hourly Count > 0 AND SO2 Method Code is null)
Rpt Period S02 Mass Reported Accumulator Array for the location = -1
Rpt Period S02 Mass Calculated Accumulator Array for the location = -1
return result B
Else if (S02 Derived Hourly Count >1)
Rpt Period S02 Mass Reported Accumulator Array for the location = -1
Rpt Period S02 Mass Calculated Accumulator Array for the location = -1
return result C
Else if (S()2 Derived Hourly Count > 0 AND SO2 Method Code == "AD" AND Hourly Fuel Flow Count for Gas +
Hourly Fuel Flow Count for Oil == 0)
Rpt Period S02 Mass Reported Accumulator Array for the location = -1
Rpt Period S02 Mass Calculated Accumulator Array for the location = -1
return result G
Else if {S02 Derived Hourly Count ==1)
Current S02 DerivedHourly Record = DerivedHourly ValueData rec matching with param S02 or S02M where
Current Date = DerivedHourly ValueData.Date and Current Horn = DerivedHourly ValueData.Hour
If (LME HI Method is not null)
If (S02 Method Code == "LME")
If (Current SO2 Derived Hourly ParameterCode == "S02M")
S02MDerived Checks Needed = true
else
Rpt Period S02 Mass Reported Accumulator Array for the location = -1
Rpt Period S02 Mass Calculated Accumulator Array for the location = -1
return result H
else
Rpt Period S02 Mass Reported Accumulator Array for the location = -1
Rpt Period S02 Mass Calculated Accumulator Array for the location = -1
Environmental Protection Agency
Page 538 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
If {Current S02 Derived Hourly Record. ParameterCode == "S02M")
Rpt Period S02 Mass Reported Accumulator Array for the location = -1
Rpt Period S02 Mass Calculated Accumulator Array for the location = -1
return result H
else
SO2 Derived Checks Needed = true
If (S()2 Method Code in set {CEMF23,AMS})
if (S()2 Method Code == "CEMF23")
SO2 CEM Method Active For Hour = true
if (Current SO2 Derived Hourly Record. Fo rmula Idcnt i fic r is not null)
S02 Formula Record = MonitorFormulaData record where
MonitorFormulaData.FormulaID = Current S02 Derived Hourly
Record. F o rm u 1 a I dc n t i fi c r
If (S02 Formula Record is not null)
If (S02 Formula Record.ParameterCode == "S02")
if (S02 Method Code == "CEMF23")
If (S02 Formula Record.EquationCode == "F-23")
SO2 F23 Method Active For Hour = true
SO2 CEM Method Active For Hour = false
if (S02 Method Code == "AMS")
If (S02 Formula Record.EquationCode in set
{F-l,F-2})
S02 Method Code == "CEM"
SO2 CEM Method Active For Hour = true
If {SO2 F23 Method Active For Hour == true)
F23 Default Record Count = count active MonitoringDefaultData Records for the
location where ParameterCd = 'S02R' and DefaultPurposeCd = 'F23'
if (F23 Default Record Count == 0)
return result D
else if (F23 Default Record Count > 1)
F23 Default Max Value = Highest DefaultValue field from active
MonitoringDefaultData record for location where ParameterCd = 'S02R' and
DefaultPurposeCd = 'F23'
F23 Default Min Value = Lowest DefaultValue field from active
MonitoringDefaultData record for location where ParameterCd = 'S02R' and
DefaultPurposeCd = 'F23'
If (F23 Default Max Value <= 0 OR F23 Default Min Value <= 0)
return result E
else
F23 Default Value = DefaultValue field from active MonitoringDefaultData
record for location where ParameterCd = 'S02R' and DefaultPurposeCd = 'F23'
Environmental Protection Agency
Page 539 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
If (F23 Default Value <= 0)
return result E
else
If SO2 Derived Hourly Count > 0
Return result F
Results:
Result
Response
Severity
A
You did not report a DHV record for S02 (or S02M) for the hour.
Critical Error Level 1
B
You reported a DHV record for S02 (or S02M), but you did not report an active S02
method record in your monitoring plan for the hour.
Critical Error Level 1
C
You reported more than one DHV records for S02 (or S02M) for the hour.
Critical Error Level 1
D
You did not report an active S02R default record in your monitoring plan for use in
F23 calculation for the hour.
Critical Error Level 1
E
The DefaultValue reported in the active S02R F23 default record in your monitoring
plan is invalid.
Critical Error Level 1
F
You reported a DHV record for S02 (or S02M), but this is not appropriate for a
non-operating hour.
Critical Error Level 1
G
You reported a DHV record for [param], but you did not report any Hourly Fuel Flow
records at the location.
Critical Error Level 1
H
The ParameterCode reported in the DHV record does not match the ParameterCode in
the Method record in your monitoring plan used to determine [eparam].
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Environmental Protection Agency
Page 540 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOUROP-18
Check Name: Verily Single S02 Concentration record
Related Former Checks:
Applicability:
Description:
Specifications:
Current S02 Monitor Hourly Record = null
SO2 Monitor Hourly Count = count of MonitorHourly ValueDate records with param" S02C" where
Current Date = MonitorHourly ValueData.Date and
Current Hour = MonitorHourly ValueData.Hour
If Unit Hourly Operational Status = true
If (S02 Monitor Hourly Count >0 AND SO 2 CEM Method Active For Hour == false AND MATS S02C Needed == false)
Return result A
Else if (SO2 Monitor Hourly Count >1)
Return result B
Else if {SO2 Monitor Hourly Count ==1)
Current S02 Monitor Hourly Record = MonitorHourly ValueData rec with param S02C where
CurrentDate = MonitorHourly ValueData.Date and
CurrentHour = MonitorHourly ValueData.Hour
Else
if (SO2 Monitor Hourly Count > 0)
return result C
Results:
Result
A
B
C
Response
You reported an MHV record for S02C, but you did not report an active S02 method
record in your monitoring plan for the hour.
You reported more than one MHV record for S02C for the hour.
You reported an MHV record for S02C, but this is not appropriate for a non-operating
hour.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1
Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Environmental Protection Agency
Page 541 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOUROP-19
Check Name: Verily Single NOx Concentration Record
Related Former Checks:
Applicability:
Description:
Specifications:
Current NOx Cone Monitor Hourly Record = null
NOx Cone Monitor Hourly Count = count of MonitorHourly ValueDate records with param "NOXC" where
Current Date = MonitorHourly ValueData.Date and
Current Hour = MonitorHourly ValueData.Hour
if Unit Hourly Operational Status = true
if (NOx Cone Monitor Hourly Count >1)
Return result A
Else if (NOx Cone Monitor Hourly Count ==1)
If {NOx Mass Monitor Method Code in {CEM, CEMNOXR, AMS} OR Current NOx Rate Method Code in
{CEM,AMS})
Current NOx Cone Monitor Hourly Record = MonitorHourly ValueData rec with param "NOXC" where
CurrentDate = MonitorHourly ValueData.Date and
CurrentHour = MonitorHourlyValueData.Hour
else
return result B
Else
if (NOx Cone Monitor Hourly Count > 0)
return result C
Results:
Result
A
B
C
Response
You reported more than one MHV record for NOXC for the hour.
You reported an MHV record for NOXC, but you did not report an appropriate NOXR
or NOX method record in your monitoring plan for the hour.
You reported an MHV record for NOXC, but this is not appropriate for a non-operating
hour.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1
Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Environmental Protection Agency
Page 542 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOUROP-20
Check Name:
Verily Single NOx Rate Derived Hourly Record
Related Former Checks:
Applicability:
Description:
Specifications:
If (Derived Hourly Checks Needed == true)
NOx Rate Derived Checks Needed = false
NOx Rate Derived Hourly Count = count of DerivedHourly ValueData records with ParameterCode = "NOXR" where
Current Date = DerivedHourly ValueData.Date and
Current Hour = DerivedHourly ValueData.Hour
If Current Hourly Op Record. OperatingTime > 0
If (NOx Rate Derived Hourly Count == 0 AND Current NOx Rate Method Code is not null)
Return result A
Else if (NOx Rate Derived Hourly Count > 0 AND Current NOx Rate Method Code is NULL)
Rpt Period NOx Rate Reported Accumulator Array for the location = -1
Rpt Period NOx Rate Calculated Accumulator Array for the location = -1
Return result B
Else if {NOx Rate Derived Hourly Count >1)
Rpt Period NOx Rate Reported Accumulator Array for the location = -1
Rpt Period NOx Rate Calculated Accumulator Array for the location = -1
Return result C
Else if (NOx Rate Derived Hourly Count == 1)
Current NOx Rate Derived Hourly Record = DerivedHourly ValueData rec matching param NOXR
NOx Rate Derived Checks Needed = true
Apportionment NOXR Method Array at Was location= Current NOx Rate Method Code
If (Current NOx Rate Method Code == "AMS")
if (Current NOx Rate Derived Hourly . Fo rmu 1 a I dc nt i fic r is null)
if Current NOx Rate Derived Hourly Record.MODCCode is not null)
Current NOx Rate Method Code = "CEM"
else
NOXR Formula Record = MonitorFormulaData record where
MonitorFormulaData.FormulalD = Current NOx Rate Derived Hourly
Record. Fo rm u 1 a I dc n t i fi c r
If (NOXR Formula Record is not null)
If (NOXR Formula Record.ParameterCode == "NOXR" AND NOXR Formula
Record.EquationCode in set
{F-5,F-6,19-1,19-2,19-3,19-3D,19-4,19-5,19-5D,19-6,19-7,19-8,19-9})
Current NOx Rate Method Code = "CEM"
else
If NOx Rate Derived Hourly Count > 0
Return result D
Environmental Protection Agency
Page 543 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
A
B
C
D
Response
You did not report a DHV record for NOXR for the hour.
You reported a DHV record for NOXR, but you did not report an active NOXR method
record in your monitoring plan for the hour.
You reported more than one DHV record for NOXR for the hour.
You reported a DHV record for NOXR, but this is not appropriate for a non-operating
hour.
This check result is obsolete.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
No Errors
Usage:
1
Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Environmental Protection Agency
Page 544 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOUROP-21
Check Name:
Verily Single NOx Mass Derived Hourly Record
Related Former Checks:
Applicability:
Description:
Specifications:
If (Derived Hourly Checks Needed == true)
NOx Mass Derived Checks Needed = false
NOXMDerived Checks Needed = false
Current NOx Mass Derived Hourly Record = null
NOx Mass Derived Hourly Count = count of DerivedHourly ValueData records with ParameterCode = "NOX" or "NOXM" where
Current Date = DerivedHourly ValueData.Date and
Current Hour = DerivedHourly ValueData.Hour
If Current Hourly Op /?6'tw 0
If (NOx Mass Derived Hourly Count == 0 AND (NOx Mass Method Active For Hour == true OR NOx Mass Monitor
Method Code == "LME"))
Return result A
Else if (NOx Mass Derived Hourly Count > 0 AND NOx Mass Method Active For Hour == false AND NOx Mass
Monitor Method Code <> "LME")
Rpt Period NOx Mass Reported Accumulator Array for the location = -1
Rpt Period NOx Mass Calculated Accumulator Array for the location = -1
Return result B
Else if {NOx Mass Derived Hourly Count >1)
Rpt Period NOx Mass Reported Accumulator Array for the location = -1
Rpt Period NOx Mass Calculated Accumulator Array for the location = -1
Return result C
Else if (NOx Mass Derived Hourly Count > 0 AND Current NOx Rate Method Code == "AE" AND Hourly Fuel Flow
Count for Gas + Hourly Fuel Flow Countfor Oil == 0)
Rpt Period NOx Mass Reported Accumulator Array for the location = -1
Rpt Period NOx Mass Calculated Accumulator Array for the location = -1
Return result E
Else if (NOx Mass Derived Hourly Count == 1)
Current NOX Mass Derived Hourly Record = DerivedHourly ValueData rec matching with param NOX or
NOXM where Current Date = DerivedHourly ValueData.Date and Current Hour =
DerivedHourlyValueData.Hour
If (LME HI Method is not null)
If (NOx Mass Monitor Method Code == "LME")
if (Current NOX Mass Derived Hourly Record. ParameterCode == "NOXM")
NOXM Derived Checks Needed = true
else
Rpt Period NOx Mass Reported Accumulator Array for the location = -1
Rpt Period NOx Mass Calculated Accumulator Array for the location = -1
return result F
else
Rpt Period NOx Mass Reported Accumulator Array for the location = -1
Rpt Period NOx Mass Calculated Accumulator Array for the location = -1
else
Environmental Protection Agency
Page 545 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
if {Current NOXMass Derived Hourly Record.ParameterCode == "NOXM")
Rpt Period NOx Mass Reported Accumulator Array for the location = -1
Rpt Period NOx Mass Calculated Accumulator Array for the location = -1
return result F
else
NOx Mass Derived Checks Needed = true
If {NOx Mass Monitor Method Code in set {AMS, CEMNOXR})
If {NOx Rate Derived Hourly Count > 0)
NOx Mass Monitor Method Code = "NOXR"
Else if {NOx Mass Monitor Method Code == "CEMNOXR")
NOx Mass Monitor Method Code == "CEM"
Else if {Current NOx Mass Derived Hourly . Fo rmu 1 a I dc n t i fic r is not null)
NOX Formula Record = MonitorFormulaData record where
MonitorFormulaData.FormulalD = Current NOx Mass Derived Hourly
Record. F ormulaldentifier
If (NOX Formula Record is not null)
If (NOX Formula Record.ParameterCode == "NOX" AND NOX
Formula Record.EquationCode in set {F-26A,F-26B})
NOx Mass Monitor Method Code = "CEM"
Apportionment NOX Method Array at this location = NOx Mass Monitor Method Code
else
If NOx Mass Derived Hourly Count > 0
Return result D
Results:
Result
A
B
C
D
Response
You did not report a DHV record for NOX (or NOXM) for the hour.
You reported a DHV record for NOX (or NOXM), but you did not report an active
NOX (or NOXM) method record in your monitoring plan for the hour.
You reported more than one DHV record for NOX (or NOXM) for the hour.
You reported a DHV record for NOX (or NOXM), but this is not appropriate for a
non-operating hour.
You reported a DHV record for [param], but you did not report any Hourly Fuel Flow
records at the location.
The ParameterCode reported in the DHV record does not match the ParameterCode in
the Method record in your monitoring plan used to determine [eparam].
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 546 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
Usage:
1 Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Environmental Protection Agency
Page 547 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOUROP-22
Check Name: Verily Single C02 Mass Derived Hourly Value Record
Related Former Checks:
Applicability:
Description:
Specifications:
If (Derived Hourly Checks Needed == true)
CO 2 Mass Derived Checks Needed = false
Current C02 Mass Derived Hourly Record = null
C02MDerived Checks Needed = false
CO2 Mass Derived Hourly Count = count of DerivedHourly ValueData records with ParameterCode beginning with "C02" where
Current Date = DerivedHourly ValueData.Date and
Current Hour = DerivedHourly ValueData.Hour
If Current Hourly Op Ttecon/.OperatingTime > 0
If (CO2 Mass Derived Hourly Count == 0 AND CO2 Method Code is not null AND C02 Method Code <> "FSA")
If (C02 Method Code == "AD")
If (Hourly Fuel Flow Countfor Gas + Hourly Fuel Flow Count for Oil > 0)
return result A
else
Return result A
Else if (CO 2 Mass Derived Hourly Count > 0 AND (CO 2 Method Code is null OR CO 2 Method Code== "FSA"))
Rpt Period C02 Mass Reported Accumulator Array for the location = -1
Rpt Period C02 Mass Calculated Accumulator Array for the location =-1
return result B
Else if (C02 Mass Derived Hourly Count >1)
Rpt Period C02 Mass Reported Accumulator Array for the location = -1
Rpt Period C02 Mass Calculated Accumulator Array for the location =-1
Return result C
Else if (CO2 Mass Derived Hourly Count > 0 AND C02 Method Code == "AD" AND Hourly Fuel Flow Count for
Gas + Hourly Fuel Flow Countfor Oil == 0)
Rpt Period C02 Mass Reported Accumulator Array for the location = -1
Rpt Period C02 Mass Calculated Accumulator Array for the location =-1
Return result E
Else if (C02 Mass Derived Hourly Count == 1)
Current C02 Mass Derived Hourly Record = DerivedHourly ValueData rec matching with param C02 or C02M
where Current Date = DerivedHourly ValueData.Date and Current Horn = DerivedHourly ValueData.Hour
If (LME HI Method is not null)
If (C()2 Method Code == "LME")
if {Current C02 Mass Derived Hourly Record ParameterCode == "C02M")
C02MDerived Checks Needed = true
else
Rpt Period C02 Mass Reported Accumulator Array for the location = -1
Rpt Period C02 Mass Calculated Accumulator Array for the location =-1
return result F
else
Rpt Period C02 Mass Reported Accumulator Array for the location = -1
Rpt Period C02 Mass Calculated Accumulator Array for the location = -1
else
if {Current C02 Mass Derived Hourly Record.¥arameterCode == "C02M")
Rpt Period C02 Mass Reported Accumulator Array for the location = -1
Rpt Period C02 Mass Calculated Accumulator Array for the location = -1
Environmental Protection Agency
Page 548 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
return result F
else
CO 2 Mass Derived Checks Needed = true
ff (C02 Method Code == "AMS")
if (Current CO2 Mass Derived Hourly Record. Fo rmu 1 a Idcnt i ficr is not null)
C02 Formula Record = MonitorFormulaData record where
MonitorFormulaData.FormulalD = Current C02 Mass Derived Hourly
Record. F ormulaldentifier
If (C02 Formula Record is not null)
If (C02 Formula Record.ParameterCode == "C02" AND C02 Formula
Record.EquationCode in set {F-2,F-11})
C02 Method Code == "CEM"
CO 2 CEM Method Active For Hour = true
Else
If CO2 Mass Derived Hourly Count > 0
Return result D
Results:
Result Response Severity
A You did not report a DHV record for C02 (or C02M) for the hour. Critical Error Level 1
B You reported a DHV record for C02 (or C02M), but you did not report an active C02 Critical Error Level 1
(or C02M) method record in your monitoring plan for the hour.
C You reported more than one DHV records for C02 (or C02M) for the hour. Critical Error Level 1
D You reported a DHV record for C02 (or C02M), but this is not appropriate for a Critical Error Level 1
non-operating hour.
E You reported a DHV record for [param], but you did not report any Hourly Fuel Flow Critical Error Level 1
records at the location.
F The ParameterCode reported in the DHV record does not match the ParameterCode in Critical Error Level 1
the Method record in your monitoring plan used to determine [eparam].
Usage:
1 Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Environmental Protection Agency
Page 549 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOUROP-23
Check Name:
Verily C02 Cone Derived and Monitor Hourly Data Record
Related Former Checks:
Applicability:
Description:
Specifications:
Current C02 Cone Derived Hourly Record = null
Current C02 Cone Monitor Hourly Record = null
Current C02 Cone Missing Data Monitor Hourly Record = null
CO2 Cone Derived Checks Needed = false
CO2 Cone Monitor Checks Needed = false
02 Dry Needed to Support C02 Calculation = false
02 Wet Needed to Support C02 Calculation = false
CO2 Cone Derived Hourly Count = count of DerivedHourly ValueData records with ParameterCode = "C02C" where
Current Date = DerivedHourly ValueData.Date and
Current Hour = DerivedHourly ValueData.Hour
CO2 Cone Monitor Hourly Count = count of MonitorHourly ValueData records with ParameterCode = "C02C" where
Current Date = MonitorHourly ValueData.Date and
Current Hour = MonitorHourly ValueData.Hour
Total C02 Cone Records = C02 Cone Derived Hourly Count + CO2 Cone Monitor Hourly Count
If (Current Hourly Op Record.OperatingTime > 0)
If ((C02 Cone Checks Needed for Heat Input == true) OR (CO2 Diluent Checks Needed for NOx Rate Calc == true) OR (CO2
Diluent Neededfor MATS == true) OR (CO2 Cone Checks Neededfor C02 Mass Calc == true))
If ((CO2 Cone Monitor Hourly Count == 0) AND ((CO2 Cone Checks Needed for Heat Input == true) OR (CO2 Diluent
Checks Needed for NOx Rate Calc == true) OR (CO2 Diluent Needed for MA TS == true)))
return result B
else if (Total C02 Cone Records == 0)
return result A
else if ((C02 Cone Monitor Hourly Count == 2) AND (CO2 Cone Derived Hourly Count == 0) AND ((C02 Diluent
Checks Needed for NOx Rate Calc == true) OR (CO2 Diluent Needed for MA TS == true)) AND ((C02 Cone Checks
Needed for Heat Input == true) OR (CO2 Cone Checks Needed for C02 Mass Calc = true))
Current C02 Cone Monitor Hourly Record = Find MonitorHourly ValueData records with ParameterCode =
"C02C" and MODCCode in set {01, 02, 03, 04, 53, 54} where
Current Date = MonitorHourly ValueData.Date and
Current Hour = MonitorHourly ValueData.Hour
Current C02 Cone Missing Data Monitor Hourly Record = Find MonitorHourly ValueData records with
ParameterCode = "C02C" and MODCCode not in set {01, 02, 03, 04, 54} where
Current Date = MonitorHourly ValueData.Date and
Current Hour = MonitorHourly ValueData.Hour
If (Current C02 Cone Monitor Hourly Record is null OR Current C02 Cone Missing Data Monitor Hourly
Record is null)
return result C
else
CO2 Cone Monitor Checks Needed = true
Environmental Protection Agency
Page 550 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
else if (Total C02 Cone Records > 1)
return result C
else if (CO 2 Cone Derived Hourly Count == 1)
CO2 Cone Derived Checks Needed = true
Current C02 Cone Derived Hourly Record = matching DerivedHourly ValueData rec
if (Current C02 Cone Derived Hourly Record.MODCCode in set {01, 02, 03, 04, 05, 21, 53, 54}
Fc Factor Needed = true
Fd Factor Needed = true
If (Current C02 Cone Derived Hourly RecordFomnAa Id Key is not null)
C02C Formula record = Find MonitoringFormulaData record where
MonitoringFormulalDKey = Current C02 Cone Derived Hourly
Record.Formula Id Key
If (C02C Formula record is not null)
If (C02C Formula recordParameterCode == "C02C")
If (C02C Formula record.EquationCode == "F-14A")
02 Dry Needed to Support C02 Calculation = true
else if (C02C Formula record.EquationCode == "F-14B")
02 Wet Needed to Support C02 Calculation = true
Moisture Needed = true
else if (CO2 Cone Monitor Hourly Count == 1)
CO2 Cone Monitor Checks Needed = true
Current C02 Cone Monitor Hourly Record = matching MonitorHourly ValueData rec
else
If (Total C02 Cone Records > 0)
Return result D
else
If (Total C02 Cone Records > 0)
Return result E
Results:
Result
Response
Severity
A
You did not report a MHV or DHV record for C02C for the hour.
Critical Error Level 1
B
You did not report an MHV record for C02C for the hour.
Critical Error Level 1
C
You reported more than one MHV and/or DHV records for C02C for the hour.
Critical Error Level 1
D
You reported a MHV or DHV record for C02C, but this record is not required to
Non-Critical Error
calculate emissions.
E
You reported a MHV or DHV record for C02C, but this is not appropriate for a
Critical Error Level 1
non-operating hour.
Environmental Protection Agency
Page 551 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
Usage:
1 Process/Category: Emissions Data Evaluation Report Unit-Level Evaluation
Environmental Protection Agency
Page 552 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOUROP-24
Check Name:
Count Hourly Fuel Flow Records
Related Former Checks:
Applicability:
Description:
Specifications:
If (Derived Hourly Checks Needed == true)
Hourly Fuel Flow Count For Oil = 0
Hourly Fuel Flow Count For Gas = 0
Appendix D Method Active = Heat Input App D Method Active For Hour OR
CO 2 App D Method Active For Hour OR
S02 App D Method Active For Hour
Hourly Fuel Flow List = set of all DerivedHourly ValueData records
Current Date = DerivedHourly ValueData.Date and
Current Hour = DerivedHourly ValueData.Hour
For each record (Current Hourly Fuel Flow Record) in Hourly Fuel Flow List
Cur Fuel Code = Current Hourly Fuel Flow Record.FuelCode
if (Cur Fuel Code is null)
return result D
Current Fuel Group = select FuelGroupCode from FuelCode Table where FuelCode = Cur Fuel Code
if {Current Fuel Group is null)
return result D
else If Current Fuel Group == "GAS"
Add 1 to Hourly Fuel Flow Count For Gas
else if Current Fuel Group == "OIL"
Add 1 to Hourly Fuel Flow Count For Oil
Hourly Fuel Flow Count = Hourly Fuel Flow Count For Gas + Hourly Fuel Flow Count For Oil
If {Current Hourly Op Record.LocationNamc begins with "CP")
CP Fuel Count = CP Fuel Count + Hourly Fuel Flow Count
If {Current Hourly Op Record.OpcratingTimc== 0)
If {Hourly Fuel Flow Count > 0)
if {Appendix D Method Active = true AND Hourly Fuel Flow Count == 0 AND MP Pipe Config for Hourly Checks is
null)
Return result B
else if {Appendix D Method Active = false AND Hourly Fuel Flow Count >0)
Return result A
else
return result C
Environmental Protection Agency
Page 553 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
A
B
C
D
Usage:
1
Response
You reported an HFF record, but this is not appropriate for a non-operating hour.
You did not report an HFF record for the hour.
You reported a HFF record, but you did not report an active AD or AE method record
in your monitoring plan for the hour.
The FuelCode reported in the HFF record is missing or invalid.
Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 554 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOUROP-30
Check Name: Determine Load Based Status of unit
Related Former Checks:
Applicability:
Description:
Specifications:
Unit is Load Based = false
Location Name = Current Monitor Plan Location Record. LOC ATIONN AIVIE
if the Location Name begins with "CS" or "CP" or "MS" or "MP"
Locate all Unit Stack Configuration records where the stack/pipe location is the monitoring location, the BeginDate is on or before
the Current Date, and the EndDate is null or is on or after the Current Date.
If the NonLoadBasedlndicator in all of the retrieved records is equal to 1,
Unit is Load Based = false
else
Unit is Load Based = true
else // current location is a unit
if the NonLoadBasedlndicator field for the unit = 1
Unit is Load Based = false
else
Unit is Load Based = true
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Environmental Protection Agency
Page 555 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOUROP-32
Check Name: Perform Load Checks for Operating Hour
Related Former Checks:
Applicability:
Description:
Specifications:
if {Current Hourly Op Record is not null)
Apportionment OpTime Array for this location = Current Hourly Op Record.OperatingTime
Apportionment Load Array for this Location = Current Hourly Op Record. Hourly Load
if (Unit is Load Based == true and Current Hourly Op Ttecon/.OperatingTime > 0.0)
if (Current Hourly Op Record. HourLoad is null OR Current Hourly Op Record.HourLoad < 0)
if (Current Entity Type= "Unit")
Unit LoadTimesOpTime Accumulator = -1
else if (Current Entity Type in set {CP, MP})
Pipe LoadTimesOpTime Accumulator = -1
else
Stack LoadTimesOpTime Accumulator = -1
return result A
else
if (MPStack Config for Hourly Checks == 'MS" AND Current Entity Type == "Unit")
MP Unit Load = Current Hourly Op Record.HourLoad
if (Current Entity Type= "Unit")
if (Unit LoadTimesOpTime Accumulator >= 0)
Unit LoadTimesOpTime Accumulator = Unit LoadTimesOpTime Accumulator +
(Current Hourly Op Record .HourLoad * Current Hourly Op Record. OperatingTime)
else if (Current Entity Type in set {CP, MP})
if (Pipe LoadTimesOpTime Accumulator >= 0)
Pipe LoadTimesOpTime Accumulator = Pipe LoadTimesOpTime Accumulator +
(Current Hourly Op Record .HourLoad * Current Hourly Op Record. OperatingTime)
else
if (Stack LoadTimesOpTime Accumulator >= 0)
Stack LoadTimesOpTime Accumulator = Stack LoadTimesOpTime Accumulator +
(Current Hourly Op Record.HourLoad * Current Hourly Op Record. OperatingTime)
if Current Hourly Op Record. LoadU nitsOfMcasurcCodc not in {"MW","KLBHR", "MMBTUHR"}
MP Load UOM = "INVALID"
return result B
else if (MP Load UOM is not null AND MP Load UOM <> "INVALID" AND MP Load UOM <> Current
Hourly Op Record. LoadU nitsOflVIcasurcCodc)
MP Load UOM = "INVALID"
return result C
else
if (MPLoad UOM is null)
MP Load UOM = Current Hourly Op Record. LoadU nitsOflVIcasurcCodc
Locate the MonitorLoadRecordsByHourandLocation record for the hour and location.
If (only one record is found AND MonitorLoadRecordByHourandLocation.Maxim\imLoadVal\ie is
greater than 0),
Environmental Protection Agency
Page 556 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
If {CurrentHourly Op Record.LoadUnitsOflVIcasurcCodc ==
MonitorLoadRecordByHourandLocation.MaxiimimLoad\JmtsOfMeasureCodd)
If {Current Hourly Op Record .HourLoad is greater than
MonitorLoadRecordByHourandLocation.MaximamLoadValue)
return result H
else if {Current Hourly Op Record .HourLoad == 0)
If {Current Hourly Op Record.LoadRange is greater than or equal to 2 OR
Current Hourly Op Record. Commo nStackLoadRa nge is greater than or equal to
2)
If {Current Entity Type <> "Unit" OR {MP Stack Configfor Hourly
Checks <> "CS" AND MP Pipe Config for Hourly Checks <> "CP"))
return result K
else
return result I
else
return result J
else if {Current Hourly Op Record.OperatingTillie == 0.0)
if {Current Hourly Op Record.HourLoad is not null)
return result D
if Current Hourly Op Record. LoadU nitsOflVIcasurcCodc is not null
return result E
else if {Unit is Load Based == false)
if {Current Hourly Op Record.HourLoad is not null)
return result F
if Current Hourly Op Record. LoadU nitsOflVIcasurcCodc is not null
return result G
Environmental Protection Agency
Page 557 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
A
B
C
D
E
F
G
H
I
J
K
Usage:
1
Response
The HourLoad reported in the Hourly Operating record is invalid. The value must be
greater than or equal to 0.
The LoadUnitsOfMeasureCode reported in the Hourly Operating record is invalid.
You did not report the same LoadUnitsOfMeasureCode for all locations in the
configuration.
You reported HourLoad in the Hourly Operating record. This field should be blank for
a non-operating hour.
You reported a LoadUnitsOfMeasureCode in the Hourly Operating record. This field
should be blank for a non-operating hour.
You reported HourLoad in the Hourly Operating record. This field should be blank for
a non-load-based unit.
You reported a LoadUnitsOfMeasureCode in the Hourly Operating record. This field
should be blank for a non-load-based unit.
Warning: The HourLoad reported in the Hourly Operating Data record is higher than
the MaximumLoadValue in the Monitoring Load record reported in your monitoring
plan. Sources are required to periodically (at least once annually) evaluate the
appropriateness of these maximum values in the monitoring plan and make proper
adjustments when necessary. You should investigate the cause of these exceedances
and determine whether an adjustment to the MaximumLoadValue in your monitoring
plan is necessary.
The [fieldname] does not correspond to the MaximumLoadUnitsOfMeasure reported in
the monitoring plan.
You did not have one and only one valid Monitor Load record that was active during
the hour.
The LoadRange or CommonStackLoadRange reported in the Hourly Operating record
is inconsistent with the HourLoad. When no load is generated, the load range should be
less than 2.
You reported an HourLoad in the Hourly Operating Data record that is 125% or greater
than the MaximumLoadValue in the Monitoring Load record reported in your
monitoring plan.
Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Non-Critical Error
Critical Error Level 1
Critical Error Level 1
Informational Message
Critical Error Level 2
Critical Error Level 1
Informational Message
Critical Error Level 1
Environmental Protection Agency
Page 558 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOUROP-33
Check Name: Check reported Fuel Code for Operating Hour
Related Former Checks:
Applicability:
Description:
Specifications:
if {Current Hourly Op Record is not null)
Fuel Code Validation Needed = false
If (NOx Rate Fuel Specific Missing Data == true OR NOx Mass Fuel Specific Missing Data == true OR SO 2 Fuel Specific
Missing Data == true OR CO 2 Fuel Specific Missing Data == true OR Heat Input Fuel Specific Missing Data == true OR H20
Fuel Specific Missing Data == true)
Fuel Code Validation Needed = true
else
if (Current S02 Monitor Hourly Record is not null AND S02 Bypass Code == "BYMAXFS")
if {Current S02 Monitor Hourly Record.MODCCode == 23)
Fuel Code Validation Needed = true
if {Current NOx Cone Monitor Hourly Record is not null AND NOx Mass Bypass Code == "BYMAXFS")
if {Current NOx Cone Monitor Hourly Record MODCCode in set {23,24})
Fuel Code Validation Needed = true
if {Current NOx Rate Derived Hourly Record is not null AND NOx Rate Bypass Code== "BYMAXFS")
if {Current NOx Rate Derived Hourly Record MODCCode in set {23,24})
Fuel Code Validation Needed = true
if {Fuel Code Validation Needed == true)
if {Current Hourly Op Record.FuelCode is null)
If {Current Hourly Op Record .Ope rat i ngT i me is greater than 0)
return result A
else
Current Hourly Fuel Group Code = FuelGroupCode from FuelCode table entry where
FuelCode = Current Hourly Op Record.FuelCode
if {Current Hourly Op Record.FuelCode = "NFS" OR
{Current Hourly Fuel Group Code == "COAL" AND Current Hourly Op Record.FuelCode <> "C"))
return result B
else if {Current Hourly Op Record FuelCode is not null)
if (S()2 Bypass Code <> "BYMAXFS" AND NOx Rate Bypass Code <> "BYMAXFS" AND NOx Mass Bypass Code <>
"BYMAXFS")
return result C
Results:
Result
A
B
C
Response Severity
You did not report a FuelCode in the Hourly Operating record. Critical Error Level 1
The FuelCode reported Hourly Operating record is invalid. Critical Error Level 1
You reported a FuelCode in the Hourly Operating record. This value should only be Critical Error Level 1
reported if you use fuel-specific missing data or have an unmonitored bypass stack that
reports emissions based on fuel-specific maximum values.
Environmental Protection Agency
Page 559 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
Usage:
1 Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Environmental Protection Agency
Page 560 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOUROP-34
Check Name:
Validate Reported FC Factor
Related Former Checks:
Applicability:
Description:
Validation Tables:
F-Factor Range Checks (Cross Check Table)
Specifications:
if FC Factor Needed = true
Valid FC Factor Exists = false
if {Current Hourly Op Record.FcFactor is null)
return result A
else if (Current Hourly Op Record FcF actor <= 0)
return result A
else
Valid FC Factor Exists = true
if (Special Fuel Burned = false)
FC Factor Minimum = Lookup Lower from Cross-Check Table "F-Factor Range Checks" where Factor = "FC"
FC Factor Maximum = Lookup Upper from Cross-Check Table "F-Factor Range Checks" where Factor = "FC"
if (Current Hourly Op Record.FcFactor > FC Factor Maximum OR Current Hourly Op Record. FcFactor < FC
Factor Minimum)
return result B
Results:
Result
A
B
Response
The [FNAME] reported in the Hourly Operating record is missing or invalid.
The [FNAME] reported in the Hourly Operating record is outside of the expected range
from [MIN] to [MAX],
Severity
Critical Error Level 1
Critical Error Level 2
Usage:
1 Process/Category: Emissions Data Evaluation Report Unit-Level Evaluation
Environmental Protection Agency
Page 561 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOUROP-35
Check Name:
Validate Reported FD Factor
Related Former Checks:
Applicability:
Description:
Validation Tables:
F-Factor Range Checks (Cross Check Table)
Specifications:
if FD Factor Needed = true
Valid FD Factor Exists = false
if {Current Hourly Op RecordFdF&ctox is null)
return result A
else if (Current Hourly Op RecordFdFactor <= 0)
return result A
else
Valid FD Factor Exists = true
if (Special Fuel Burned = false)
FD Factor Minimum = Lookup Lower from Cross-Check Table "F-Factor Range Checks" where Factor = "FD"
FD Factor Maximum = Lookup Upper from Cross-Check Table "F-Factor Range Checks" where Factor = "FD"
if (Current Hourly Op Record. FdF actor > FD Factor Maximum OR Current Hourly Op Record .V AV'c\c\or < FD
Factor Minimum)
return result B
Results:
Result
A
B
Response
The [FNAME] reported in the Hourly Operating record is missing or invalid.
The [FNAME] reported in the Hourly Operating record is outside of the expected range
from [MIN] to [MAX],
Severity
Critical Error Level 1
Critical Error Level 2
Usage:
1 Process/Category: Emissions Data Evaluation Report Unit-Level Evaluation
Environmental Protection Agency
Page 562 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOUROP-36
Check Name:
Validate Reported FW Factor
Related Former Checks:
Applicability:
Description:
Validation Tables:
F-Factor Range Checks (Cross Check Table)
Specifications:
if FW Factor Needed = true
Valid FW Factor Exists = false
if {CurrentHourly Op Record .¥w¥i\c\ox is null)
return result A
else if (Current Hourly Op Record.FwFactor <= 0)
return result A
else
Valid FW Factor Exists = true
if (Special Fuel Burned = false)
FW Factor Minimum = Lookup Lower from Cross-Check Table "F-Factor Range Checks" where Factor = "FW"
FWFactor Maximum = Lookup Upper from Cross-Check Table "F-Factor Range Checks" where Factor = "FW"
if (Current Hourly Op Record .FwFactor > FW Factor Maximum OR Current Hourly Op Record .FwFactor <
FW Factor Minimum)
return result B
Results:
Result
A
B
Response
The [FNAME] reported in the Hourly Operating record is missing or invalid.
The [FNAME] reported in the Hourly Operating record is outside of the expected range
from [MIN] to [MAX],
Severity
Critical Error Level 1
Critical Error Level 2
Usage:
1 Process/Category: Emissions Data Evaluation Report Unit-Level Evaluation
Environmental Protection Agency
Page 563 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOUROP-37
Check Name: Verily Single Heat Input Derived Hourly Record
Related Former Checks:
Applicability:
Description:
Specifications:
Current Heat Input Derived Hourly Record= null
Heat Input Derived Checks Needed = false
HIT Derived Checks Needed = false
Heat Input Derived Hourly Count = # of DerivedHourly ValueData record with parameter beginning with "HI" where
Current Date = DerivedHourly ValueData.Date and
Current Hour = DerivedHourly ValueData.Hour
If Current Hourly Op Record.Opcrati ngTime > 0
If (Heat Input Derived Hourly Count == 0)
If {Heat Input Method Code is not null)
If (Heat Input Method Code not in set {EXP, LTFF})
return result A
else if (Heat Input Method Code == "LTFF" AND Current Entity Type == "Unit")
return result A
Else if (Heat Input Derived Hourly Count > 0 AND
(Heat Input Method Code is null OR
Heat Input Method Code == "EXP" OR
(Heat Input Method Code== "LTFF" AND Current Entity Type == "CP"))
Rpt Period HI Reported Accumulator Array for the location =-1
Rpt Period HI Calculated Accumulator Array for the location = -1
return result B
Else if (Heat Input Derived Hourly Count >1)
Rpt Period HI Reported Accumulator Array for the location =-1
Rpt Period HI Calculated Accumulator Array for the location = -1
return result C
Else
Current Heat Input Derived Hourly Record= DerivedHourly ValueData record with parameter "HI" or "HIT" where
Current Date = DerivedHourly ValueData.Date and
Current Hour = DerivedHourly ValueData.Hour
If (LME HI Method is not null)
if (Current Heat Input Derived Hourly Record.ParameterCode == "HIT")
HIT Derived Checks Needed = true
else
Rpt Period HI Reported Accumulator Array for the location =-1
Rpt Period HI Calculated Accumulator Array for the location = -1
return result E
else
if (Current Heat Input Derived Hourly Record.ParameterCode == "HIT")
Rpt Period HI Reported Accumulator Array for the location =-1
Rpt Period HI Calculated Accumulator Array for the location = -1
return result E
else
Heat Input Derived Checks Needed = true
If (Heat Input Method Code == "AMS")
if (Current Heat Input Derived Hourly Record. Formulaldentifier is not null)
Environmental Protection Agency
Page 564 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
HI Formula Record = MonitorFormulaData record where
MonitorFormulaData.FormulalD = Current Heat Input Derived Hourly
Record. Fo rm u 1 a I dc lit i fi c r
If (HI Formula Record is not null)
If (HI Formula Record.ParameterCode == "HI" AND HI Formula
Record.EquationCode in set {F-15,F-16,F-17,F-18})
Heat Input Method Code == "CEM"
Heat Input CEM Method Active For Hour == true
else
If Heat Input Derived Hourly Count > 0
return result D
Results:
Result
A
B
C
D
Response Severity
You did not report a DHV record for HI (or HIT) for the hour. If you have entered Critical Error Level 1
LME data via the LME Emissions Data Utility, this error indicates that you have not yet
generated your quarterly emissions data. You must do this by clicking on the Generate
Emissions Data link on the LME Emissions Data Utility submenu.
You reported a DHV record for HI (or HIT), but, according to the monitoring methods Critical Error Level 1
in your monitoring plan, you should not report hourly heat input at this location.
You reported more than one DHV record for HI (or HIT) for the hour.
You reported a DHV record for HI (or HIT), but this is not appropriate for a
non-operating hour.
The ParameterCode reported in the DHV record does not match the ParameterCode in
the Method record in your monitoring plan used to determine [eparam].
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1
Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Environmental Protection Agency
Page 565 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOUROP-38
Check Name: Determine Fuel Type
Related Former Checks:
Applicability:
Description:
Specifications:
If (Derived Hourly Checks Needed == true)
If Current Hourly Op Record.FcFactor is not null OR Current Hourly Op Recordactor is not null OR Current Hourly Op
Record.FwFactor is not null
If (Hourly Fuel Flow Count For Oil + Hourly Fuel Flow Count For Gas == 0)
If (Current Hourly Op Record.FuelCd is null OR Current Hourly Op Record.FuelCd == 'MIX")
Count all active UnitFuel records for the location where
FuelCd in set {OOL, PRG, PRS, OGS}
If count > 0
Special Fuel Burned = true
else if Current Hourly Op Record. U nitFuclCd in set {OOL, PRG, PRS, OGS}
Special Fuel Burned = true
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Unit-Level Evaluation
Environmental Protection Agency
Page 566 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOUROP-39
Check Name:
Verily Single H20 Cone Derived or Monitor Hourly Data Record
Related Former Checks:
Applicability:
Description:
Specifications:
H20 Monitor Hourly Checks Needed = false
H20 Derived Hourly Checks Needed = false
CurrentH20 Monitor Hourly Record = null
Current H20 Derived Hourly Record = null
02 Wet Checks Neededfor H20= false
02 Dry Checks Neededfor H20= false
If Current Hourly Op Record.Opcrati ngTi 111c > 0.00
If (Moisture Needed == true)
If H20 Monitor Hourly Count + H20 Derived Hourly Count == 0
If (H2() Method Code == "MWD")
return result A
Else if (H20 Method Code <> "MDF")
return result B
Else if H20 Default Max Value is not null
return result C
Else if (H20 Derived Hourly Count >1)
return result D
Else if (H20 Monitor Hourly Count >1)
return result E
Else if (H20 Derived Hourly Count == 1 AND H20 Method Code in set {MTB, MMS})
return result F
Else if (H20 Monitor Hourly Count == 1 AND H20 Method Code in set {MWD, MDF})
return result G
Else if (H20 Monitor Hourly Count ==1)
CurrentH20 Monitor Hourly Record = MonitorHourly ValueData record matching with ParameterCode = "H20"
where
Current Date = MonitorHourly ValueData.Date and
Current Hour = MonitorHourly ValueData.Hour
H20 Monitor Hourly Checks Needed = true
Else if (H20 Derived Hourly Count ==1)
Current H20 Derived Hourly Record = DerivedHourly ValueData rec matching where
DerivedHourly ValueData.ParameterCode = "H20" AND
DerivedHourly ValueData.Date = Current Date AND
DerivedHourly ValueData.Hour = Current Hour
Environmental Protection Agency
Page 567 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
H20 Derived Hourly Checks Needed = true
if (Current H2() Derived Hourly Record. ModcCodc in set {01, 02, 03, 04, 05, 21, 53, 54} AND CurrentH20
I)eri ved Hourly Record. Fo rmu 1 a I dc n t i fic r is not null)
H20 Formula Record = MonitorFormulaData record where
MonitorFormulaData.FormulalD = Current H20 Derived Hourly Record. Fo ri nil 1 a I dc n t i fi e r
If (H20 Formula Record is not null)
If (H20 Formula Record.ParameterCode == "H20" AND H20 Formula Record.EquationCode in
set {F-31, M-1K})
02 Wet Checks Needed for H20= true
02 Dry Checks Needed for H20= true
else
If H20 Monitor Hourly Count + H20 Derived Hourly Count > 0
return result H
else
If H20 Monitor Hourly Count + H20 Derived Hourly Count > 0
return result I
Results:
Result
A
B
C
D
E
F
G
H
Usage:
1
Response
You did not report a DHV record for H20 for the hour.
You did not report an MHV record for H20 for the hour.
You did not report a DHV record for H20 for the hour. You must report this record if
you have multiple H20 default values for different fuels.
You reported more than one DHV record for H20 for the hour.
You reported more than one MHV record for H20 for the hour.
You reported a DHV record for H20, but the H20 MethodCode is not "MWD" or
"MDF".
You reported a MHV record for H20, but the H20 MethodCode is not "MTB" or
"MMS".
You reported a DHV and/or MHV record for H20, but this record is not required to
calculate emissions.
You reported a DHV and/or MHV record for H20, but this is not appropriate for a
non-operating hour.
Process/Category: Emissions Data Evaluation Report Unit-Level Evaluation
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Informational Message
Critical Error Level 1
Environmental Protection Agency
Page 568 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOUROP-40
Check Name:
Verily Single 02 Dry Monitor Hourly Value Record
Related Former Checks:
Applicability:
Description:
Specifications:
Current 02 Dry Monitor Hourly Record = null
Current 02 Dry Missing Data Monitor Hourly Record = null
02 Dry Monitor Hourly Checks Needed = false
If Current Hourly Op Record.Opcrati ngTi me > 0.00
If ((()2 Dry Checks Needed for Heat Input == true) OR (02 Dry Checks Needed for NOx Rate Calc == true) OR (02 Dry Checks
Needed To Support C02 Calculation == true) OR (()2 Dry Checks Neededfor H20 == true) OR (()2 Dry Neededfor MA TS ==
true))
If ((()2 Dry Monitor Hourly Count == 0) AND ((()2 Wet Checks Needed for Heat Input == true) OR (02 Wet Checks
Neededfor NOx Rate Calc == true) OR (()2 Wet Checks Needed To Support C02 Calculation == true) OR (()2 Wet
Checks Needed for H20 == true) OR (02 Wet Needed for MA TS == true)))
return result A
Else if (()2 Dry Monitor Hourly Count + 02 Null Monitor Hourly Count == 0)
Return result B
Else if ((()2 Dry Monitor Hourly Count + 02 Null Monitor Hourly Count > 2) OR (02 Dry Monitor Hourly Count +
02 Null Monitor Hourly Count == 2 AND 02 Wet Monitor Hourly Count + 02 Null Monitor Hourly Count ==2))
Return result C
Else if (()2 Dry Monitor Hourly Count + 02 Null Monitor Hourly Count == 2)
If (()2 Dry Checks Needed for Heat Input == true AND (()2 Dry Checks Needed for NOx Rate Calc == true OR
02 Dry Checks Neededfor H20 == true) OR (02 Dry Needed for MA TS == true))
Current 02 Dry Monitor Hourly Record = Find MonitorHourly ValueData records with ParameterCode =
"02C" AND (MoistureBasis = "D" OR MoistureBasis is null) and MODCCode in set {01, 02, 03, 04, 53,
54} where
Current Date = MonitorHourly ValueData.Date and
Current Hour = MonitorHourly ValueData.Hour
Current 02 Dry Missing Data Monitor Hourly Record = Find MonitorHourly ValueData records with
ParameterCode = "02C" AND (MoistureBasis = "D" OR MoistureBasis is null) and MODCCode not in
set {01, 02, 03, 04, 54} where
Current Date = MonitorHourly ValueData.Date and
Current Hour = MonitorHourly ValueData.Hour
If (Current 02 Dry Monitor Hourly Record is null OR Current 02 Dry Missing Data Monitor Hourly
Record is null)
return result C
else
02 Dry Monitor Hourly Checks Needed = true
else
return result C
Else if (()2 Dry Monitor Hourly Count == 1)
Environmental Protection Agency
Page 569 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
02 Dry Monitor Hourly Checks Needed = true
Current 02 Dry Monitor Hourly Record = MonitorHourly ValueData record with ParameterCode = "02C" AND
MoistureBasis = "D" where
Current Date = MonitorHourly ValueData.Date and
Current Hour = MonitorHourly ValueData.Hour
Else if (()2 Null Monitor Hourly Count ==1)
02 Dry Monitor Hourly Checks Needed = true
Current 02 Dry Monitor Hourly Record = Current 02 Null Monitor Hourly Record
else
If (()2 Dry Monitor Hourly Count > 0)
Return result D
If ((()2 Null Monitor Hourly Count > 0) AND (02 Wet Checks Needed for Heat Input == false) AND (02 Wet Checks
Neededfor NOx Rate Calc == false) AND (()2 Wet Checks Needed To Support C02 Calculation == false) AND (()2
Wet Checks Needed for H20 == false) AND (()2 Wet Needed for MA TS == false))
return result E
else
If (02 Dry Monitor Hourly Count 02 + Null Monitor Hourly Count + 02 Wet Monitor Hourly Count > 0)
Return result F
Results:
Result
A
B
Response
You did not report a MHV record for 02C with a MoistureBasis of D for the hour.
You did not report a MHV record for 02C with a MoistureBasis of D (or blank) for the
hour.
You reported too many MHV records for 02C with a MoistureBasis of D (or blank) for
the hour.
You reported an MHV record for 02C with a MoistureBasis of [basis], but this record
is not required to calculate emissions.
You reported an MHV record for 02C with a blank MoistureBasis, but this record is
not required to calculate emissions.
You reported a MHV record for 02C, but this is not appropriate for a non-operating
hour.
Severity
Critical Error Level 1
Critical Error Level 1
C
Critical Error Level 1
D
Non-Critical Error
E
Non-Critical Error
F
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Unit-Level Evaluation
Environmental Protection Agency
Page 570 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOUROP-41
Check Name: Verily Single 02 Wet Monitor Hourly Value Record
Related Former Checks:
Applicability:
Description:
Specifications:
Current 02 Wet Monitor Hourly Record = null
Current 02 Wet Missing Data Monitor Hourly Record = null
02 Wet Monitor Hourly Checks Needed = false
If Current Hourly Op Record.Opcrati ngTi me > 0.00
If ((()2 Wet Checks Neededfor Heat Input == true) OR (()2 Wet Checks Needed for NOx Rate Calc == true) OR (()2 Wet
Checks Needed To Support C02 Calculation == true) OR (()2 Wet Checks Needed for H20 == true) OR (()2 Wet Needed for
MATS == true))
If ((()2 Wet Monitor Hourly Count == 0) AND ((()2 Dry Checks Needed for Heat Input == true) OR (()2 Dry Checks
Neededfor NOx Rate Calc == true) OR (02 Dry Checks Needed To Support C02 Calculation == true) OR (02 Dry
Checks Needed for H20 == true) OR (02 Dry Needed for MA TS == true)))
return result A
Else if (02 Wet Monitor Hourly Count + 02 Null Monitor Hourly Count == 0)
Return result B
Else if (02 Wet Monitor Hourly Count + 02 Null Monitor Hourly Count > 2)
Return result C
Else if (()2 Wet Monitor Hourly Count + 02 Null Monitor Hourly Count == 2
If ((02 Wet Checks Needed for Heat Input == true) AND (02 Dry Monitor Hourly Count + 02 Null
Monitor Hourly Count <> 2) AND ((()2 Wet Checks Needed for NOx Rate Calc == true) OR (()2 Wet
Checks Needed for H20 == true) OR (02 Wet Needed for MA TS == true)))
Current 02 Wet Monitor Hourly Record = Find MonitorHourly ValueData records with
ParameterCode = "02C" AND (MoistureBasis = "W" OR MoistureBasis is null) and
MODCCode in set {01, 02, 03, 04, 53, 54} where
Current Date = MonitorHourly ValueData.Date and
Current Hour = MonitorHourlyValueData.Hour
Current 02 Wet Missing Data Monitor Hourly Record = Find MonitorHourlyValueData records
with ParameterCode = "02C" AND (MoistureBasis = "W" OR MoistureBasis is null) and
MODCCode not in set {01, 02, 03, 04, 54} where
Current Date = MonitorHourly ValueData.Date and
Current Hour = MonitorHourlyValueData.Hour
If (Current 02 Wet Monitor Hourly Record is null OR Current 02 Wet Missing Data Monitor
Hourly Record is null)
return result C
else
02 Wet Monitor Hourly Checks Needed = true
else
return result C
Else if (02 Wet Monitor Hourly Count == 1)
Environmental Protection Agency
Page 571 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
02 Wet Monitor Hourly Checks Needed = true
Current 02 Wet Monitor Hourly Record = MonitorHourly ValueData record with ParameterCode =
"02C" AND MoistureBasis = "W" where
Current Date = MonitorHourly ValueData.Date and
Current Hour = MonitorHourly ValueData.Hour
Else if (02 Null Monitor Hourly Count == 1)
02 Wet Monitor Hourly Checks Needed = true
Current 02 Wet Monitor Hourly Record = Current 02 Null Monitor Hourly Record
else
If (02 Wet Monitor Hourly Count > 0)
Return result D
Results:
Result
A
B
Response
You did not report a MHV record for 02C with a MoistureBasis of W for the hour.
You did not report a MHV record for 02C with a MoistureBasis of W (or blank) for the
hour.
You reported too many MHV records for 02C with a MoistureBasis of W (or blank)
for the hour.
You reported an MHV record for 02C with a MoistureBasis of [basis], but this record
is not required to calculate emissions.
Severity
Critical Error Level 1
Critical Error Level 1
C
Critical Error Level 1
D
Non-Critical Error
Usage:
1 Process/Category: Emissions Data Evaluation Report Unit-Level Evaluation
Environmental Protection Agency
Page 572 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
HOUROP-42
Check Name:
Verily Single S02R Derived Hourly Data Record
Related Former Checks:
Applicability:
Description:
Specifications:
If (Derived Hourly Checks Needed == true)
S02R Derived Checks Needed = false
S02R Derived Hourly Count = count of DerivedHourly ValueData records with ParameterCode = "S02R" where
Current Date = DerivedHourly ValueData.Date and
Current Hour = DerivedHourly ValueData.Hour
If Current Hourly Op Record.Opcrati ngTi mc > 0
If (S02R Derived Hourly Count == 0 AND F23 Default Max Value is not null)
Return result A
Else if (S02R Derived Hourly Count > 0 AND SO2 F23 Method Active For Hour == false)
Return result B
Else if (S02R Derived Hourly Count >1)
Return result C
Else if (S02R Derived Hourly Count ==1)
Current S02R Derived Hourly Record = DerivedHourly ValueData rec matching with param S02R where
Current Date = DerivedHourly ValueData.Date and
Current Hour = DerivedHourly ValueData.Hour
S02R Derived Checks Needed = true
else
If S02R Derived Hourly Count > 0
Return result D
Results:
Result
A
B
Response
You did not report a DHV record for S02R for the hour.
You reported a DHV record for S02R, but this record is not required to calculate
emissions.
You reported more than one DHV record for S02R for the hour.
You reported a DHV record for S02R, but this is not appropriate for a non-operating
hour.
Severity
Critical Error Level 1
Non-Critical Error
C
D
Critical Error Level 1
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Environmental Protection Agency
Page 573 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: HOUROP-43
Check Name: Validate Single Stack Flow Record
Related Former Checks:
Applicability:
Description:
Specifications:
Current Stack Flow Hourly Record= null
If Flow Monitor Hourly Checks Needed == true)
If (Flow Monitor Hourly Count == 0)
Flow Monitor Hourly Checks Needed = false
return result A
Else if (Flow Monitor Hourly Count >1)
return result B
Else
Current Stack Flow Hourly Record = MonitorHourly ValueData record with parameter FLOW where
Current Date = MonitorHourly ValueData.Date and
Current Hour = MonitorHourly ValueData.Hour
else
If Flow Monitor Hourly Count > 0
return result C
Results:
Result
A
B
C
Response Severity
You did not report an MHV record for FLOW for the hour. Critical Error Level 1
You reported more than one MHV record for FLOW for the hour. Critical Error Level 1
You reported a MHV record for FLOW, but this record is not appropriate for the hour. Non-Critical Error
Usage:
1
Process/Category: Emissions Data Evaluation Report Unit-Level Evaluation
Environmental Protection Agency
Page 574 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Category:
Leak Status
Environmental Protection Agency
Page 575 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
LKSTAT-1
Check Name:
Locate Most Recent Prior Leak Check
Related Former Checks:
Applicability:
Description:
Specifications:
Set PriorLeakRecord = null.
Locate the most recent record in LeakCheckRecordsByLocationForQAStatus for the location where:
a) the ComponentID is equal to the CurrentMHV.ComponentW
b) the TestResultCd is not equal to "INVALID" and
c) the EndDate/Hour is on or prior to the CurrentMHVRecord. Datc/Hour
if (LeakCheckRecordsByLocationForQAStatus is found)
Set PriorLeakRecord = the found record in LeakCheckRecordsByLocationForQAStatus.
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Leak Check Status Evaluation
Environmental Protection Agency
Page 576 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: LKSTAT-2
Check Name: Locate Most Recent Prior Event
Related Former Checks:
Applicability:
Description:
Specifications:
Set PriorLeakEventRecord = null.
Set LeakStatusResult = null
If (PriorLeakRecord is null)
Locate the latest record in QACertiflcationEventRecords where the ComponentID is equal to the CurrentMHV.ComponentID,
QaCertEventCode is equal to "300" or "305", and the QACertEventDate/Hour is prior to CurrentReportingPeriod.
if (QACertificationEventRecord is found)
Set PriorLeakEventRecord = the found record in QACertificationEventRecord.
Locate the latest record in RataTestRecordsByLocationForQaStatus where the SystemID is equal to
CurrentMhvRecord.Svstcml D. TestReasonCode is equal to "INITIAL" or "RECERT", TestResultCode is equal to
"PASSED", and EndDateHour is after QACertificationEventRecord.QACertEveniDate/Hour and is prior to
CurrentReportingPeriod.
if found,
Set LeakStatusResult = "OOC-Event".
else
Set LeakStatusResult — "IC".
else
Locate the SystemComponent record with the earliest BeginDate where the ComponentID is equal to the
CurrentMHV.ComponentID.
If found, and the BeginDate in the SystemComponent record is in the current reporting period,
Set LeakStatusResult = "IC"
else
Set LeakStatusResult = "OOC-No Prior Test".
else
Locate the latest record in QACertiflcationEventRecords where the ComponentID is equal to the CurrentMHV .Components),
LeakRequired is equal to "Y" and QaCertEventCode is not equal to "300", and the QACertEventDate/Hour is prior to the
CurrentMHVRecord Date/Hour and after the Priori.ectkRecord. EndDatc/Hour.
if a record is found
Set PriorLeakEventRecord = the found record in QACertiflcationEventRecords.
if Priori. eakE vent Record. La s t Co m p 1 c t c dTc s t D a t c is not null
Set ExpectedLeakCheckQuarter = the quarter of PriorLeakEventRecord.LastCompletedTestDate.
else
Set ExpectedLeakCheckQuarter = the quarter after Priori. eakE vent Record. Q A C c rt E v c n t D a t c.
Set QuartersAfterCount = 0.
For each quarter beginning with ExpectedLeakCheckQuarter and ending with CurrentReportingPeriod,
Environmental Protection Agency
Page 577 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
if QuartersAfterCount is equal to 4,
Set RequiredLeakCheckQuarter to quarter.
Exit the loop.
else if AnnualReportingRequirement equals true, or the quarter being checked is 2 or 3
if AnnualReportingRequirement equals true, or the quarter being checked is 3
Locate the record in OperatingSuppDataRecordsByLocation where OpTypeCode is equal to
"OPHOURS", FuelCode is null, and reporting period equals the quarter being checked
else
Locate the record in OperatingSuppDataRecordsByLocation where OpTypeCode is equal to
"OSHOURS", FuelCode is null, and reporting period equals the quarter being checked
if OperatingSuppDataRecordsByLocation record is found
If ()peratingSuppI)ataRecordsliyLocation.OpVa 1 lie >= 168
Set RequiredLeakCheckQuarter to quarter.
Exit the loop.
else
Set RequiredLeakCheckQuarter to quarter.
Exit the loop.
Increament QuartersAfterCount by 1.
if RequiredLeakCheckQuarter is prior to CurrentReportingPeriod
Set LeakStatusResult ="OOC-Event".
else
Set LeakStatusResult = "IC".
else if T^iorZ.eaWfecwY/.QANeedsEvaluationFlag = "Y"
Set LeakStatusResult = "Prior Test Not Yet Evaluated".
else if PriorLeakRecord.TestResultCd is null
Set LeakStatusResult = "OOC-Test Has Critical Errors".
else if Priori.eak Record.TestResultCd == "FAILED"
Set LeakStatusResult = "OOC-Test Failed".
else if Priori. eak Record. TestResultCd == "ABORTED"
Set LeakStatusResult = "OOC-Test Aborted".
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Leak Check Status Evaluation
Environmental Protection Agency
Page 578 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: LKSTAT-3
Check Name: Determine Expiration Date For Prior Leak Check
Related Former Checks:
Applicability:
Description:
Specifications:
if (LeakStatusResuIt is null)
Set PriorLeakExpirationDate = Priori, eak Record. Tc s t E \ p i ra t i o n D a tc.
if (PriorLeakExpirationDate is null)
if {Annual Reporting Requirement == false)
if (PriorLeakRecord .TestEndQuarter = "2")
Set PriorLeakExpirationDate = September 30th following PriorLeakRecord .EndDate.
else
Set PriorLeakExpirationDate = June 30th following PriorLeakRecord .EndDate.
else
if (PriorLeakRecord .GracePeriodlnd =1)
Set PriorLeakExpirationDate = the end of the quarter of the PriorLeakRecord.EndDate.
else
Set PriorLeakExpirationDate = the end of the quarter following the quarter of the PriorLeakRecord
.EndDate.
Set PriorLeakRecord TestExpirationDate = PriorLeakExpirationDate.
if {CurrentMHVRecord.Date is ON OR BEFORE the PriorLeakExpirationDate)
Set LeakStatusResuIt = "IC".
else
Set PriorLeakExpirationDate = null.
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Leak Check Status Evaluation
Environmental Protection Agency
Page 579 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
LKSTAT-4
Check Name:
Related Former Checks:
Determine Extended Expiration Date for Prior Leak Check
Applicability:
Description:
Specifications:
Set LeakMissingOpDatalnfo = null.
if (LeakStatusResult is null)
Set MissingOpData = false
if (PriorL eakRecord. Tc s t E \ p i ra t i o n D a tc W i t h E \ t c n s i o n is null)
For each quarter beginning with the quarter of the PriorLeakExpirationDate and continuing through the quarter prior to
the quarter of the CurrentMHVRecord.Date:
if (EarliestLocationReportDate > the last day of the quarter being checked)
Set NumberOfExtensionQuarters = NumberOJExtensionQuarters + 1.
else
If (Annual Reporting Requirement == true OR the quarter being checked is == 2 or 3)
If (AnnualReporting Requirement == true OR the quarter being checked == 3)
Locate a record in OperatingSuppDataRecordsByLocation where the reporting period is
equal to the year/quarter being checked and the OpTypeCode = "OPHOURS" and
FuelCode is null.
else
Locate a record in OperatingSuppDataRecordsBy Location where the reporting period is
equal to the year/quarter being checked and the OpTypeCode = "OSHOURS" and
FuelCode is null.
if (OperatingSuppDataRecordsByLocation is found AND
OperatingSuppDataRecordsBy Location.OpV'Muc < 168)
If (Annual Reporting Requirement = true OR the quarter being checked == 2)
Set NumberOfExtensionQuarters — NumberOfExtensionQuarters + 1.
else
Set NumberOfExtensionQuarters = NumberOfExtensionQuarters + 3.
else if (OperatingSuppDataRecordsByLocation is not found)
If (the quarter being checked == 1 or 4)
Locate a LocationReportingFrequency record for the test location where
ReportingFrequencyCode = "OS", the Begin Quarter is on or before the quarter
being checked and the EndQuarter is null or is on or after the quarter being
checked.
Environmental Protection Agency
Page 580 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
If (LocationReportingFrequency record is found)
if (Annual Reporting Requirement == true and the quarter being
checked == 4 and the year of the EndQuarter is equal to the year of the
quarter being checked.
Set NumberOfExtensionQuarters =
NumberOfExtensionQuarters + 1.
else
else
else
Stop looking for extensions.
Set Missing Op Data to true.
Set LeakMissingOpDatalnfo = "[YEAR] Q[QTR]" (where [YEAR] is
the year of the quarter being checked and [QTR] is the number of the
quarter being checked.)
Stop looking for extensions.
Set Missing Op Data to true.
Set LeakMissingOpDatalnfo = "[YEAR] Q[QTR]" (where [YEAR] is the year
of the quarter being checked and [QTR] is the number of the quarter being
checked.)
Stop looking for extensions.
Stop looking for extensions.
else
Add NumberOfExtensionQuartersto PriorLeakExpirationDate
Set Priori,eakRecord. TcstE\pi ratio nDatc Wi thE\tcnsio n = PriorLeakExpirationDate
else
Set PriorLeakExpirationDate = Priori.eakRecord. Tc s t E\ p i ra t io n Da tc W i t h E\ tc lis io n
If (CurrentMHVRecord.Date/Hour is ON OR BEFORE the PriorLeakExpirationDate)
Set LeakStatusResult = "IC-Extension".
else if (Missing Op Data == true)
Set LeakStatusResult = "Missing Op Data".
Set Priori.eakRecord. Tc s t E\ p i ra t i o n Da tc W i t h E \ tc lis i o n = null
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Leak Check Status Evaluation
Environmental Protection Agency
Page 581 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
LKSTAT-5
Check Name:
Determine Grace Period for Leak Check
Related Former Checks:
Applicability:
Description:
Specifications:
if (LeakStatusResuIt is null)
if (Annual Reporting Requirement == false)
Set LeakStatusResuIt = "OOC-Expired".
else if (Rpt Period Op Hours Accumulator Array for the location == -1)
Set LeakStatusResuIt = "Invalid Op Data".
Set GraceOpHours = RptPeriodOpHoursAccumulatorArray for the location,
if (GraceOpHours > 168)
Set LeakStatusResuIt = "OOC-Expired".
else
If the quarter after the LATER of the PriorLeakExpirationDate and the EarliestLocationReportDate is the
quarter of the CurrentMHVRecord.Date/Hour,
Set LeakStatusResuIt = "IC-Grace".
else
For each quarter beginning with the quarter after the LATER of the PriorLeakExpirationDate and the
EarliestLocationReportDate ,and continuing through the quarter prior to the
CurrentMHVRecord Date/Hour,
if (EarliestLocationReportDate <= the last day of the quarter being checked)
else
Locate a record in OperatingSuppDataRecordsByLocation where the reporting period is
equal to the year/quarter being checked and the OpTypeCode = "OPHOURS" and
FuelCode is null.
if (OperatingSuppDataRecordsByLocation is found)
Add OpValue to GraceOpHours.
if (GraceOpHours > 168)
Set LeakStatusResuIt = "OOC-Expired".
exit for.
else
Set LeakStatusResuIt = 'Missing Op Data".
Set LeakMissingOpDatalnfo = "[YEAR] Q[QTR]" (where [YEAR] is the year
Environmental Protection Agency
Page 582 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
of the quarter being checked and [QTR] is the number of the quarter being
checked.)
exit for.
if (LeakStatusResuIt is null)
Set LeakStatusResult = "IC-Grace".
if LeakStatusResult does not begin with "IC"
return LeakStatusResult
Results:
Result
Invalid Op Data
Missing Op Data
OOC-Event
OOC-Expired
OOC-No Prior
Test
OOC-Test
Aborted
OOC-Test Failed
OOC-Test Has
Critical Errors
Prior Test Not
Yet Evaluated
Usage:
1
Severity
Critical Error Level 1
Response
The [testtype] status for [key] could not be determined, because the OperatingTime in at
least one Hourly Operating Data records was missing or invalid.
The Leak Check status for [COMPID] could not be determined, because the Op Supp Critical Error Level 1
Data record for OPHOURS or OSHOURS is missing for [MISSINGOPDATAINFO]
(and possibly other previous reporting periods). If you have submitted emissions data
for prior quarters, you should be able to retrieve these records by logging on to the EPA
host.
You reported a QA Certification Event record for QACertEventCode [code]
QACertEventDate [eventdate] for [compid], but you did not perform a subsequent leak
check.
The prior leak check for [compid] completed on [date] has expired.
You did not report a prior [testtype] for [key].
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
The prior leak check for [compid] completed on [date] was aborted.
The prior leak check for [compid] completed on [date] failed.
The prior leak check for [compid] completed on [date] has critical errors.
The [testtype] status for [key] could not be determined, because the applicable prior
[testtype] with TestNumber [testnum] has not yet been evaluated.
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Process/Category: Emissions Data Evaluation Report Leak Check Status Evaluation
Environmental Protection Agency
Page 583 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Category:
Linearity Status
Environmental Protection Agency
Page 584 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: LINSTAT-1
Check Name: Check Analyzer Range Exemption For Linearity Status
Related Former Checks:
Applicability:
Description:
Specifications:
Set CurrentLinearifyStatus = null
if (CurrentMHI'Parameter = "S02C" or CurrentMHI 'Parameter = "NOXC")
Locate the record in MonitorSpanRecordsByHourLocation for the hour and location where the ComponentTypeCode is equal to
the QaStatusComponentTypeCode and the SpanScaleCode is equal to the CurrentAnalyzerRangeUsed.
if (MonitorSpan Records By HourLocation is not found OR more than one MonitorSpanRecordsByHourLocation is found OR if
the MonitorSpanRecordsByHourLocation. S pa n Va 1 lie is null or <= 0)
Set CurrentLinearityStatus = "Invalid Monitor Span".
else if (MonitorSpanRecordsByHourLocation is found and MonitorSpanRecordsBy HourLocation. Span Va 1 lie <= 30)
Set CurrentLinearifyStatus = "IC-Exempt".
Results:
Result Response Severity
Usage:
1
Process/Category:
Emissions Data Evaluation Report
C02 Linearity Status Evaluation
2
Process/Category:
Emissions Data Evaluation Report
Hg Linearity Status Evaluation
3
Process/Category:
Emissions Data Evaluation Report
NOX Linearity Status Evaluation
4
Process/Category:
Emissions Data Evaluation Report
02 Dry Linearity Status Evaluation
5
Process/Category:
Emissions Data Evaluation Report
02 Wet Linearity Status Evaluation
6
Process/Category:
Emissions Data Evaluation Report
S02 Linearity Status Evaluation
Environmental Protection Agency
Page 585 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
LINSTAT-2
Check Name:
Locate Most Recent Prior Linearity Test
Related Former Checks:
Applicability:
Description:
Specifications:
Set Prior Linearity Record = null.
Set InvalidLinearityRecord = null.
if (CurrentLinearifyStatus is null)
Locate the most recent record in LinearityTestRecordsByLocationForQAStatus for the location where the ComponentID is equal
to the ApplicableComponentID and the SpanScaleCode is equal to the CurrentAnalyzerRangeUsed and the CalculatedTestResult
is not equal to "INVALID" and the EndDate/Hour is either:
a) prior to the CurrentDateHour OR
b) equal to the CurrentDateHour and the EndMinute is less than 45 and the CalculatedTestResult is equal to "PASSED" or
"PASS APS".
if (Linearity TestRecordsByLocationForQAStatus is found)
Set Prior Linearity Record = the found record in Linearity TestRecordsByLocationForQAStatus.
Locate the most recent record in Linearity TestRecordsByLocationForQAStatus for the location where the ComponentID
is equal to the ApplicableComponentID and the SpanScaleCode is equal to the CurrentAnalyzerRangeUsed and the
EndDate/Hour is prior to the CurrentDateHour and the EndDate/Hour is greater than the Prior Test Record. E ndD atc/H o u r
and the CalculatedTestResult is equal to "INVALID".
if (Linearity TestRecordsByLocationForQAStatus is found)
Set InvalidLinearityRecord = the found record in Linearity TestRecordsByLocationForQAStatus.
Locate the most recent record in Linearity TestRecordsByLocationForQAStatus for the location where the ComponentID
is equal to the ApplicableComponentID and the SpanScaleCode is equal to the CurrentAnalyzerRangeUsed and the
CalculatedTestResult is equal to "INVALID" and the EndDate/Hour is prior to the CurrentDateHour.
if (Linearity TestRecordsByLocationForQAStatus is found)
Set InvalidLinearityRecord = the found record in Linearity TestRecordsByLocationForQAStatus.
else
Results:
Result
Response
Severity
Environmental Protection Agency
Page 586 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Usage:
1
Process/Category:
Emissions Data Evaluation Report
C02 Linearity Status Evaluation
2
Process/Category:
Emissions Data Evaluation Report
Hg Linearity Status Evaluation
3
Process/Category:
Emissions Data Evaluation Report
NOX Linearity Status Evaluation
4
Process/Category:
Emissions Data Evaluation Report
02 Dry Linearity Status Evaluation
5
Process/Category:
Emissions Data Evaluation Report
02 Wet Linearity Status Evaluation
6
Process/Category:
Emissions Data Evaluation Report
S02 Linearity Status Evaluation
Environmental Protection Agency
Page 587 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: LINSTAT-3
Check Name: Locate Most Recent Prior Event
Related Former Checks:
Applicability:
Description:
Specifications:
Set PriorLinearifyEventRecord = null,
if (CurrentLinearifyStatus is null)
Locate all records in QACertificationEventRecords where:
the ComponentID is equal to the ApplicableComponentID
AND LinearityRequired is equal to "Y";
AND the QACertEventDate/Hour is either:
a) prior to the CurrentDateHour OR
b) equal to both the CurrentDateHour and the ConditionalBeginDate/Hour;
AND either
a) Prior Test Record is null OR
b) QACertEventDate/Hour is after the Prior IksfTtecon/.EndDate/Hour OR
c) QACertEventDate/Hour is equal to the PriorTestRecord. EndDatc/Hour AND (TestCompletionDate is null or the
TestCompletionDate/Hour is after the Prior TestRecord. E ndDatc/Hour)
AND either
a) DualRangeStatus = false OR
b) HighRangeComponentID <> LowRangeComponentID OR
c) QACertEventCode <> 27 or 30 or 172 and CurrentAnalyzerRangeUsed = "H" OR
d) QACertEventCode <> 35 or 171 and CurrentAnalyzerRangeUsed = "L"
AND either
a) Annual Reporting Requirement is equal to true OR
b) QACertEventDate/Hour is on or after April 1 of the year of the CurrentDateHour
if (QACertificationEventRecords is found)
Sort QACertificationEventRecords by QACertEventDate/Hour descending.
For each record in QACertificationEventRecords
Set PriorLinearifyEventRecord = the found record in QACertificationEventRecords.
if (Priori, in earityE vent Record. Q A C c rt E v e n t C o dc = 170 and DualRangeStatus = true)
Locate the record in MonitorSpanRecordsByLocation where the ComponentTypeCode is equal to
QaStatusComponentTypeCode and the SpanScaleCode is equal to the CurrentAnalyzerRangeUsed and
the BeginDate/Hour is equal to the PriorLinearityEventRecord.QACertEventDate/Hour.
if (MonitorSpanRecordsByLocation is found)
exit for loop.
Environmental Protection Agency
Page 588 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
else
set PriorLinearityEventRecord = null.
else
exit for loop.
If (PriorLinearityEventRecord is null)
If (PriorLinearityRecord is null)
Set CurrentLinearityStatus = "OOC-No Prior Test or Event".
else if (InvalidLinearityRecord is not null ANDPriorLinearityEventRecord.QACertEventDate/Hour is after
In validTestRecord. E ndDatc/Hour)
Locate the earliest record in Linearity TestRecordsByLocationForQAStatus where the ComponentID is equal to the
ApplicableComponentID, the SpanScaleCode is equal to the CurrentAnalyzerRangeUsed, the CalculatedTestResult is
equal to "INVALID", and the EndDate/Hour is after the PriorLinearityEventRecord.QACertEventDate/Hour and prior to
the CurrentDateHour.
if (Linearity TestRecordsByLocationForQAStatus is found)
Set InvalidLinearityRecord = the found record in Linearity TestRecordsByLocationForQAStatus.
else
Set InvalidLinearityRecord = null.
Results:
Result
Usage:
1
2
3
4
5
6
Response
Process/Category:
Process/Category:
Process/Category:
Process/Category:
Process/Category:
Process/Category:
Severity
Emissions Data Evaluation Report C02 Linearity Status Evaluation
Emissions Data Evaluation Report Hg Linearity Status Evaluation
Emissions Data Evaluation Report NOX Linearity Status Evaluation
Emissions Data Evaluation Report 02 Dry Linearity Status Evaluation
Emissions Data Evaluation Report 02 Wet Linearity Status Evaluation
Emissions Data Evaluation Report S02 Linearity Status Evaluation
Environmental Protection Agency
Page 589 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
LINSTAT-4
Check Name:
Determine Expiration Dates For Most Recent Prior Linearity Test
Related Former Checks:
Applicability:
Description:
Specifications:
Set LinearityMissingOpDatalnfo = null.
if (CurrentLinearifyStatus is blank and PriorLinearityRecord is not null and PriorLinearityEventRecord is null)
Set CheckForlgnoredLinearify = true.
Set PriorTestExpirationDate = null
Set PriorTestExpirationDate WithExtension = null
Set MissingOpData = false
if (PriorLinearityRecord.QANQQdsEvaluationFlag = "Y")
Set CurrentLinearifyStatus = "Prior Test Not Yet Evaluated".
else if (Prior Linearity Record JcstRcsultCodc = null or Priori.inearityRecord.TcstRcsu 11Codc = "FAILED" or
Priori, in earity Record. Tc s t R c s u 11C o dc = "ABORTED")
Locate the most recent record in QACertificationEventRecords where:
the ComponentID is equal to the ApplicableComponentID
AND Linearity Required is equal to "Y";
AND the ConditionalBeginDate/Hour is:
a) on or prior to the CurrentDateHour AND
b) on or after the PriorTestRecord.EndDate/Hour;
AND either
a) DualRangeStatus = false OR
b) HighRangeComponentID <> LowRangeComponentID OR
c) QACertEventCode <> 27 or 30 or 172 and CurrentAnalyzerRangeUsed = "H" OR
d) QACertEventCode <> 35 or 171 and CurrentAnalyzerRangeUsed = "L"
AND either
a) Annual Reporting Requirement is equal to true OR
b) QACertEventDate/Hour is on or after April 1 of the year of the CurrentHourlyRecordforRA TAStatus.DMc
if (QACertificationEventRecords is found)
Set PriorLinearityEventRecord = found record in QACertificationEventRecords.
elseif (Priori, in earity Record. Tc s t Re s u 11C o dc = null)
Set CurrentLinearifyStatus = "OOC-Test Has Critical Errors",
else if (Priori, in earity Record. Tc s t R c s u 11C o dc = "FAILED")
Set CurrentLinearifyStatus = "OOC-Test Failed".
Environmental Protection Agency
Page 590 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
else if (Priori.inearityRecord.TestResu 11Code = "ABORTED")
Set CurrentLinearityStatus = "OOC-Test Aborted".
else
Set PriorTestExpirationDate = Priori, in earity Record. Tc s t E \ p i ra t i o n D a t c.
Set PriorTestExpirationDate WithExtension = Priori, in earityRecord. Tc s t E \ p i ra t i o n D a tc W i t h E \ tc n s i o n.
if (PriorTestExpirationDate is null)
if {Annual Reporting Requirement == false)
if (PrioriJnearityRecord.TcslEndQunftcr = "2")
Set PriorTestExpirationDate = July 30th following Priori, in earityRecord. E nd D a t c.
else
else
Set PriorTestExpirationDate = April 30th following PriorLinearityRecord.EndDate.
Set AlternateTestDate = null
if (Priori.inearityRecord.Com\~>o\\c\\{J\\~>cCoAc is equal to "HG")
Locate the record in LocationProgramRecordsByHourLocation with the latest
EmissionsRecordingBeginDate where the ProgramCode is equal to MATS and the
EmissionsRecordingBeginDate is ON OR BEFORE the BeginDate of the associated system in the
Prior Linearity Record.
if found
Set AlternateTestDate = EmissionsRecordingBeginDate of the located record
Locate the most recent QACertificationEventRecords for the ApplicableComponentlD w here
LinearityRequired is equal to "Y", and the BeginDate/Hour is prior to the
Priori, in earityRecord. B c g i n D a tc/ H o u r.
if (QACertificationEventRecords is found AND the LinearityCertEvent is equal to "Y" and the
ConditionalDataBeginDate is null and the CompletionTestDate/Hour is after the
Priori, in earityRecord. E nd D a tc/ H o u r)
If AlternateTestDate is null
Set PriorTestExpirationDate = the end of the quarter following the quarter of the
OA Certification E ventRecords. C o m p 1 c t i o nTc s t D a tc.
Else
Set PriorTestExpirationDate = the end of the quarter following the quarter of the later of
OA Certification E ventRecords. C o m p 1 c t i o nTc s t D a tc and AlternateTestDate .
else if (Priorl.inearityRecord.GmccPcvlodlnd =1)
If AlternateTestDate is null
Set PriorTestExpirationDate = the end of the quarter of the quarter of the
Environmental Protection Agency
Page 591 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
PrioriJnearityRecord.EndDnlc.
Else
Set PriorTestExpirationDate = the end of the quarter of the quarter of the later of
PriorLinearityRecord.EndDate and AlternateTestDate .
else
If AlternateTestDate is null
Set PriorTestExpirationDate = the end of the quarter following the quarter of the
PriorlJnearityRecord.EndDdlc.
Else
Set PriorTestExpirationDate = the end of the quarter following the quarter of the later of
PriorLinearityRecord.EndDate ami AlternateTestDate .
Set Priori,inearilyRecord.TcstE\pirationDatc = PriorTestExpirationDate.
if (CurrentDateHour is ON OR BEFORE the PriorTestExpirationDate)
Set CurrentLinearityStatus = "IC".
else if {Annual Reporting Requirement == false)
Set CurrentLinearityStatus = "OOC-Expired".
else
if (PriorTestExpirationDateWithExtension is null)
Set NumberOfExtensionQuarters = 0;
For each quarter beginning with the quarter of the PriorTestExpirationDate and continuing through the
quarter prior to the quarter of the CurrentDate,
if {NumberOfExtensionQuarters = 3)
Stop looking for extensions.
else
if {EarliestLocationReportDate > the last day of the quarter being checked)
Set NumberOfExtensionQuarters — NumberOfExtensionQuarters + 1.
else
Locate a record in OperatingSuppDataRecordsByLocation where the reporting
period is equal to the year/quarter being checked and the OpTypeCode =
"OPHOURS".
if {OperatingSuppDataRecordsByLocation is found AND
OperatingSuppDataRecordsByLocation.OpValue < 168)
Set NumberOfExtensionQuarters — NumberOfExtensionQuarters + 1.
else if (Prior Linearity Record. Co mpo ncntTy pcCodc is NOT equal to "HG")
Environmental Protection Agency
Page 592 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Locate a record in TestExtensionExemptionRecords where the
ComponentID is equal to the ApplicableComponentID and the
ExtensionExemptionCode is equal to "RANGENU", and the
SpanScaleCode is equal to the CurrentAnalyzerRangeUsed and the
Year/Quarter is equal to the year/quarter to check.
if (TestExtensionExemptionRecords is found)
Set NumberOfExtensionQuarters =
NumberOfExtensionQuarters + 1.
else
Locate a record in TestExtensionExemptionRecords where the
ComponentID is equal to the ApplicableComponentID and the
ExtensionExemptionCode is equal to "NONQAPB", and the
Year/Quarter is equal to the year/quarter to check.
if (TestExtensionExemptionRecords is found)
Set NumberOfExtensionQuarters =
NumberOfExtensionQuarters + 1.
else if (OperatingSuppDataRecordsByLocation is not found)
If (the quarter being checked == 1 or 4)
Locate a LocationReportingFrequency record
for the test location where
ReportingFrequencyCode = "OS", the Begin
Quarter is on or before the quarter being
checked and the EndQuarter is null or is on or
before the quarter being checked.
If (LocationReportingFrequency record is
found)
if {Annual Reporting Requirement ==
true and the quarter being checked ==
4 and the year of the EndQuarter is
equal to the year of the quarter being
checked.
Set
NumberOfExtensionQuarters
NumberOfExtensionQuarters
+ 1.
else
Stop looking for extensions.
else
Set Missing Op Data to true.
Set LinearityMissingOpDatalnfo =
"[YEAR] Q[QTR]" (where [YEAR] is
the year of the quarter being checked
Environmental Protection Agency
Page 593 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
and [QTR] is the number of the quarter
being checked.)
Stop looking for extensions.
else
Set Missing Op Data to true.
Set LinearityMissingOpDatalnfo = " [YEAR]
Q[QTR]" (where [YEAR] is the year of the
quarter being checked and [QTR] is the number
of the quarter being checked.)
Stop looking for extensions.
else
Stop looking for extensions.
if (PrioriJnearityRecord.ComponcnfTypcCodc is NOT equal to "HG")
For each quarter beginning with the quarter after the End Quarter and continuing through the
quarter prior to the quarter of the CurrentDateHour
Locate a record in TestExtensionExemptionRecords where the ComponentID is equal to
the ApplicableComponentID and the ExtensionExemptionCode is equal to
"NONQAPB", and the Year/Quarter is equal to the year/quarter to check.
if (TestExtensionExemptionRecords is found)
Set NumberOfExtensionQuarters = NumberOfExtensionQuarters + 1.
Set PriorTestExpirationDateWithExtension = PriorTestExpirationDate.
Add NumberOfExtensionQuarters to PriorTestExpirationDate WithExtension.
Set Priori.inearity Record.TcstE\pi rationDatc WithE\tclision = PriorTestExpirationDate WithExtension.
Set PriorL in earity Record. Tc s t E \ p i ra t i o n D a tc W i t h E \ tc lis i o n = PriorTestExpirationDate
If (CurrentDateHour is ON OR BEFORE the PriorTestExpirationDateWithExtension)
Set CurrentLinearityStatus = "IC-Extension".
else if {Missing Op Data == true)
Set CurrentLinearityStatus = 'Missing Op Data".
Set PriorL in earity Record. Tc s t E \ p i ra t i o n D a t c W i t h E \ t c n s i o n = null
else if (Rpt Period Op Days Accumulator Array for the location == -1)
Set CurrentLinearityStatus = "Invalid Op Data".
Set GraceOpHours = RptPeriodOpHoursAccumulatorArray for the location,
if (GraceOpHours > 168)
Set CurrentLinearityStatus = "OOC-Expired".
Environmental Protection Agency
Page 594 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
else
Results:
Result
Usage:
1
2
3
4
5
6
Response
Process/Category:
Process/Category:
Process/Category:
Process/Category:
Process/Category:
Process/Category:
If there are NO quarters beginning with the LATER of the quarter after the
PriorTestExpirationDateWithExtension and the quarter of the EarliestLocationReportDate and
ending with the quarter prior to the CurrentDateHour,
else
Set CurrentLinearityStatus = "IC-Grace".
For each quarter beginning with the quarter after the
PriorTestExpirationDateWithExtension and continuing through the quarter prior to the
CurrentDateHour,
if (EarliestLocationReportDate <= the last day of the quarter being checked)
Locate a record in OperatingSuppDataRecordsByLocation where the
reporting period is equal to the year/quarter being checked and the
OpTypeCode = "OPHOURS" and FuelCode is null.
if (OperatingSuppDataRecordsByLocation is found)
Add OpValue to GraceOpHours.
if (GraceOpHours > 168)
Set CurrentLinearityStatus = "OOC-Expired".
exit for.
else
Set CurrentLinearityStatus = "Missing Op Data".
Set LinearityMissingOpDataInfo= "[YEAR] Q[QTR]" (where
[YEAR] is the year of the quarter being checked and [QTR] is
the number of the quarter being checked.)
exit for.
if (CurrentLinearityStatus is null)
Set CurrentLinearityStatus = "IC-Grace".
Severity
Emissions Data Evaluation Report C02 Linearity Status Evaluation
Emissions Data Evaluation Report Hg Linearity Status Evaluation
Emissions Data Evaluation Report NOX Linearity Status Evaluation
Emissions Data Evaluation Report 02 Dry Linearity Status Evaluation
Emissions Data Evaluation Report 02 Wet Linearity Status Evaluation
Emissions Data Evaluation Report S02 Linearity Status Evaluation
Environmental Protection Agency
Page 595 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
LINSTAT-5
Check Name:
Determine Event Conditional Status
Related Former Checks:
Applicability:
Description:
Specifications:
Set SubsequentLinearityRecord = null.
if (CurrentLinearifyStatus is null and PriorLinearifyEventRecord is not null)
if (/3/*iw/.irt6'«/*%£'v'6'rt?/?6'cwY/.ConditionalDataBcginDatc/Hour is null or CurrentDateHour is prior to the
/3/*iV>/*/.irt6'c//*iVv,£'v't'rt?/?6'cwY/. Conditional DataBegiiiDate/Hour)
Locate the earliest record in LinearityTestRecordsByLocationForQAStatus where the ComponentID is equal to the
ApplicableComponentID, the SpanScaleCode is equal to the CurrentAnalyzerRangeUsed, the CalculatedTestResult is not
equal to "INVALID" and the EndDate/Hour is on or after the
Prior Linear ityEventRecord.Conditiom\DataBQgvaDatQl\lom.
if (LinearityTestRecordsByLocationForQAStatus is found)
Set SubsequentLinearityRecord = the found record in LinearityTestRecordsByLocationForQAStatus.
if (LinearityTestRecordsByLocationForQAStafus.QANeedsEvaluaticmFlag = "Y")
Set CurrentLinearifyStatus = "Recertification Test Not Yet Evaluated".
else if (LinearityTestRecordsByLocationForQAStatus.TestResultCode is null)
Set CurrentLinearifyStatus = "OOC-Recertification Test Has Critical Errors".
else if (LinearityTestRecordsByLocationForQAStatus.TestResultCode = "FAILED")
Set CurrentLinearifyStatus = "OOC-Recertification Test Failed".
else if (LinearityTestRecordsByLocationForQAStatus.TestResultCode = "ABORTED")
Set CurrentLinearifyStatus = "OOC-Recertification Test Aborted".
If (InvalidLinearityRecord is null)
Locate the earliest record in Linearity TestRecordsByLocationForQAStatus where the ComponentID is
equal to the ApplicableComponentID, the SpanScaleCode is equal to the CurrentAnalyzerRangeUsed,
the CalculatedTestResult is equal to "INVALID" and the EndDate/Hour is on or after the
Prior I An ectrity Ev entRecord. Conditional Data Begi nDate/H our and is before the EndDate/EndHour of the
Linearity TestRecordsByLocationForQAStatus record retrieved above.
if (Linearity TestRecordsByLocationForQAStatus is found)
Set InvalidLinearityRecord = the found record in
Linearity TestRecordsByLocationForQAStatus.
if {CurrentLinearifyStatus is null AND Annual Reporting Requirement == false)
Set CurrentLinearityStafus = "OOC-Event".
else
Environmental Protection Agency
Page 596 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
If (SubsequentLinearityRecord is not null and SubsequentLinearity Record. EndDatc/H our is greater than
October 30th of the year of the CurrentDateHour) OR (SubsequentLinearityRecord is null and the
CurrentDateHour is in the 3rd quarter))
Set CurrentLinearityStatus = "OOC-Conditional Period Expired".
if (CurrentLinearityStatus is null)
if (PriorLinearityEventRecord.LimantvCertEyent == "Y") and (Priori.inearityEventRecord. SvstcmTvpcCode is
NOT in set (HG, ST))
if (Priori, in earityE ventRecord. E v e n t C o dc = 125)
If (Prior L in earityE ventRecord. M o n i t o ri ng S v s t e m ID is null)
Set CurrentLinearityStatus = "Invalid Certification Event"
else if (the associated BeginDate of the system in the PriorLinearityEventRecord is null)
Set CurrentLinearityStatus = "Invalid Monitor System"
else
If (the associated SystemTypeCode of the system in the PriorLinearityEventRecord ==
"S02")
Locate the record in LocationProgramRecordsByHourLocation with the latest
UnitMonitorCertBeginDate where the ProgramCode is in set {ARP, CAIRS02,
TRS02G1, TRS02G2} and the UnitMonitorCertBeginDate is ON OR BEFORE
the associated BeginDate of the system in the PriorLinearityEventRecord.
If (the record in LocationProgramRecordsByHourLocation is not found)
Locate the record in LocationProgramRecordsByHourLocation with
the latest EmissionsRecordingBeginDate where the ProgramCode is in
set {ARP, CAIRS02, TRS02G1, TRS02G2} and the
EmissionsRecordingBeginDate is ON OR BEFORE the associated
BeginDate of the system in the PriorLinearityEventRecord.
else if (the associated SystemTypeCode of the system in the PriorLinearityEventRecord
== "NOX")
Locate the record in LocationProgramRecordsByHourLocation with the latest
UnitMonitorCertBeginDate where the ProgramCode is in set {ARP, NBP,
NHNOX, CAIRNOX, CAIROS, TRNOX, TRNOXOS, SIPNOX} and the
UnitMonitorCertBeginDate is ON OR BEFORE the associated BeginDate of the
system in the PriorLinearityEventRecord.
If (the record in LocationProgramRecordsByHourLocation is not found)
Locate the record in LocationProgramRecordsByHourLocation with
the latest EmissionsRecordingBeginDate where the ProgramCode is in
set {ARP, NBP, NHNOX, CAIRNOX, CAIROS, TRNOX, TRNOXOS,
SIPNOX} and the EmissionsRecordingBeginDate is ON OR BEFORE
the associated BeginDate of the system in the
PriorLinearityEventRecord.
else if (the associated SystemTypeCode of the system in the PriorLinearityEventRecord
== "NOXC")
Locate the record in LocationProgramRecordsByHourLocation with the latest
UnitMonitorCertBeginDate where the ProgramCode is in set {NBP, NHNOX,
CAIRNOX, CAIROS, TRNOX,TRNOXOS, SIPNOX} and the
Environmental Protection Agency
Page 597 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
UnitMonitorCertBeginDate is ON OR BEFORE the associated BeginDate of the
system in the PriorLinearityEventRecord.
If (the record in LocationProgramRecordsByHourLocation is not found)
Locate the record in LocationProgramRecordsByHourLocation with
the latest EmissionsRecordingBeginDate where the ProgramCode is in
set {NBP, NHNOX, CAIRNOX, CAIROS, TRNOX,TRNOXOS,
SIPNOX} and the EmissionsRecordingBeginDate is ON OR BEFORE
the associated BeginDate of the system in the
Prior Linearity EventRecord.
Locate the record in LocationProgramRecordsByHourLocation with the latest
UnitMonitorCertBeginDate where the UnitMonitorCertBeginDate is ON OR
BEFORE the associated BeginDate of the system in the
Prior Linearity EventRecord.
If (the record in LocationProgramRecordsByHourLocation is not found)
Locate the record in LocationProgramRecordsByHourLocation with
the latest EmissionsRecordingBeginDate where the
EmissionsRecordingBeginDate is ON OR BEFORE the associated
BeginDate of the system in the Prior Linearity EventRecord.
If (the record in LocationProgramRecordsByHourLocation is not found)
Set CurrentLinearityStatus = 'Missing Program".
else if (LocationProgramRecordsByHourLocationUmtMomtorCertDeadline is not null)
if (CurrentDate is prior to the
LocationProgramRecordsByHourLocation.UmtMomtorCertDeadlme)
Set CurrentLinearityStatus = "IC-Conditional".
else
Set CurrentLinearityStatus = "OOC-Conditional Period Expired".
else
if (CurrentDate is prior to the
/. ocation ProgramRecordsIiy Hour Location. U n i t Mo n i to rCe rt B eg i n Da tc + 180
days)
Set CurrentLinearityStatus = "IC-Conditional".
else
Set CurrentLinearityStatus = "OOC-Conditional Period Expired".
else
If (the number of calendar days ON OR AFTER the
Priori, in earityEventRecord. Q A C c rt E v e n t D a t c and ON OR BEFORE the CurrentDateHour >
180)
Set CurrentLinearityStatus = "OOC-Conditional Period Expired".
else if (the quarter of the Priori, in earityE vent Record. Q A C c rt E v e n t D a tc is equal to the quarter of
the CurrentDateHour)
If (the number of calendar days ON OR AFTER the
PriorLinearityEventRecord.QACertEventDate and ON OR BEFORE the
CurrentDateHour > 90)
Environmental Protection Agency
Page 598 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
If {Rpt Period Op Hours Accumulator Array for the location == -1)
Set CurrentLinearityStatus = "Invalid Op Data".
else if (the number of calendar days ON OR AFTER the
Prior Linearity EventRecord.Q ACcvlEvcnlD'Mc and ON OR BEFORE the
CurrentDateHour is equal to Rpt Period Op Days Accumulator Array for the
location)
Set CurrentLinearity Status = "OOC-Conditional Period Expired".
else
Set CurrentLinearity Status = "IC-Conditional".
else
Set CurrentLinearity Status = "IC-Conditional".
else if (PriorL in earityE vent Record. M i nO p D ay s P ri o rQ ua rt e r is null)
Set PriorLinearityEventRecord.MinOipDaysPriorQuarter = 0
Set PriorLinearityEventRecord.MaxOpDaysPriorQuarter = 0
for each quarter beginning with the quarter of the
PriorLinearityEventRecord.QACertEventDate and continuing through the quarter
BEFORE the CurrentDateHour:
if (EarliestLocationReportDate <= the last day of the quarter being checked)
Locate the record in OperatingSuppDataRecordsbyLocation where the
OpTypeCode is equal to "OPDAYS" and the reporting period is equal to
the quarter being checked.
if (OperatingSuppDataRecordsbyLocation is not found)
Set PriorLinearityEventRecord.MmOpDaysPnorQuarter = -1
Set Linearity MissingOpDatalnfo = "[YEAR] Q[QTR]" (where
[YEAR] is the year of the quarter being checked and [QTR] is
the number of the quarter being checked,
exit for.
else
If the quarter being checked is the quarter of the
PrioriJnearity EventRecord.Q ACcr[E\cn[D't\[c
If (()peratingSuppI)ataRecordsbyLocation.OpVa 1 lie
MINUS the number of calendar days in the quarter
being checked that are PRIOR to the
PriorL in earityE vent Record. Q A C c rt E v e n t D a t c > 0)
Set
PriorL in earityE vent Record. IVI i nO p D ay s P ri o rQ
uarter =
OperatingSuppDataRecordsbyLocation. Op V al
ue MINUS the number of calendar days in the
quarter being checked that are PRIOR to the
PriorL in earityE vent Record. Q A C c rt E v e n t D a tc
If (OperatingSuppDataRecordsbyLocation.OpValue is
less than the number of calendar days in the quarter
being checked that are ON OR AFTER the
Environmental Protection Agency
Page 599 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Priori, in earityE vent Record. Q A C c rt Ey c n t D a t c)
Set
Priori, in earityE ventRecord. IVI a x O p D ay s P ri o r
Quarter =
()peratingSuppI)ataRecordsby Location. Op Va 1
ue.
else
Set
Priori, in earityE ventRecord. IVI a x O p D ay s P ri o r
Quarter = the number of calendar days in the
quarter being checked that are ON OR AFTER
the
PrioriJnearity EventRecordX) ACcr[E\cn[Dc\[c.
else
Set
Priori, in earityE ventRecord. M mO p D ay s P ri o rQ ua rtc r =
Priori, in earityE ventRecord. M mO p D ay s P ri o rQ ua rtc r +
()peratingSuppI)ataRecordsbyI. ocation. O p Va 1 lie.
Set Priori, in earityE ventRecord. IVI a \ O p D a\ s
PriorQuarter =
Priori, in earityE ventRecord. IVI a \ O p D ay s P ri o rQ ua rtc r +
()peratingSuppI)ataRecordsbyI. ocation. O p Va 1 lie.
if (Priori, in earityE ventRecord. M i nO p D ay s P ri o rQ ua rtc r == -1
set CurrentLinearityStatus to "Missing Op Data"
else if (PriorEventRecord. IVIi nOpDay s Prio rQuartcr + Rpt Period Op Days Accumulator
Array for the Location > 90)
Set CurrentLinearityStatus = "OOC-Conditional Period Expired".
else if (PriorE ventRecord. IVI axO p Day s P rio rQua rtc r + Rpt Period Op Days Accumulator
Array for the Location > 90)
Set CurrentLinearityStatus = "Undetermined-Conditional Data".
else
Set CurrentLinearityStatus = "IC-Conditional".
else
Set CurrentLinearityStatus = "IC-Conditional".
If (the quarter of the Priori, in earityE ventRecord. C o nd i t i o na 1B eg i n D a t c is equal to the quarter of the
CurrentDateHour)
Count the number of HourlyOpData records for the location where OpTime is greater than 0 and
Date/Hour is ON OR AFTER the PriorLinearityEventRecord.CondLitiomHiQgmDaiQlYiom and
ON OR BEFORE the CurrentDateHour,
If the number > 168,
Set CurrentLinearityStatus = "OOC-Conditional Period Expired".
else
Set CurrentLinearityStatus = "IC-Conditional".
Environmental Protection Agency
Page 600 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
else
if (PriorL inearityE vent Record. IVI i nOp H o u rs P rio rQua rtc r is null)
Set Priori. inearityE ventRecorcl. IVI i nO pH o u rs P ri o rQua rtc r = 0
Set Priori, in earityE ventRecorcl. IVI a \ O p H o u rs P ri o rQ ua rtc r = 0
for each quarter beginning with the quarter of the
PriorLinearityEventRecord.ConditiomlBeginDate and continuing through the quarter
BEFORE the CurrentDateHour:
if (EarliestLocationReportDate <= the last day of the quarter being checked)
if {Annual Reporting Requirement == false AND the quarter being
checked == 2)
Locate the record in OperatingSuppDataRecordsbyLocation
where the OpTypeCode is equal to "OSHOURS" and the
reporting period is equal to the quarter being checked.
else
Locate the record in OperatingSuppDataRecordsbyLocation
where the OpTypeCode is equal to "OPHOURS", FuelCode is
null, and the reporting period is equal to the quarter being
checked.
if (OperatingSuppDataRecordsbyLocation is not found)
Set Prior Lin earityE ventRecorcl. IVI i nO p H o u rs P ri o rQ ua rtc r = -1
Set Linearity MissingOpDatalnfo = "[YEAR] Q[QTR]" (where
[YEAR] is the year of the quarter being checked and [QTR] is
the number of the quarter being checked.)
exit for.
If the quarter being checked is the quarter of the
PrioriJnearityEventRecorcl.Conditiom\\Bcgu\D'Mc
If (()peratingSuppI)ataRecorclsbyL ocation. O p Va 1 lie
MINUS the number of calendar hours in the quarter
being checked that are PRIOR to the
Prior Linearity EventRecord.Condi\\\om\\Bcg\nDi\\clY{ou
r> 0)
Set
PriorL in earityE ventRecorcl. IVI i nO p H o u rs P ri o r
Quarter =
OperatingSuppDataRecordsbyLocation. Op V al
ue MINUS the number of calendar hours in the
quarter being checked that are PRIOR to the
PriorL in earityE ventRecorcl. C o nd i t i o na 1B c g i n
Date/Hour
If (()peratingSuppI)ataRecorclsbyL ocation. O p Va 1 lie is
less than the number of calendar hours in the quarter
begin checked that are ON OR AFTER the
Environmental Protection Agency
Page 601 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
PriorLinearityEventRecord.ConditionalBegiviDate/llou
r)
Set
Priori, in earityE ventRecorcl. IVI a \ O p H o u rs P ri o r
Quarter =
()percitingSuppI)citciRecorclsby Location. Op Va 1
ue.
else
Set
Priori, in earityE ventRecorcl. IVI a \ O p H o u rs P ri o r
Quarter = the number of calendar hours in the
quarter being checked that are ON OR AFTER
the
Priori An earityE ventRecorcl. Co ndit io na 1 Begin
Date/Hour.
else
Set
Priori, in earityE ventRecorcl. IVI i nO pH o u rs P ri o rQua rtc r
Priori, in earityE ventRecorcl. IVI i nO pH o u rs P ri o rQua rte r
+ OperatingSuppDataRecordsbyLocation. Op V alue.
Set Priori, in earityE ventRecorcl. IVI a \ O p H o u rs
PriorQuarter =
Priori, in earityE ventRecorcl. IVI a \ O p H o u rs P ri o rQ ua rtc r
+ OperatingSuppDataRecorclsby Location.OpV'Muc.
if (PriorLinecirityEventRecorcl.MlnOpHoursPriorQmricr == -1)
set CurrentLinearityStatus to "Missing Op Data"
else if (Rpt Period Op Days Accumulator Array for the location == -1)
if (Prior E ventRecorcl. IVI i nO pH o u rs P rio rQ ua rtc r > 168)
Set CurrentLinearity Status = "OOC-Conditional Period Expired".
else
Set CurrentLinearityStatus = "Invalid Op Data".
else
if (Prior E ventRecorcl. IVI i nO pH o u rs P ri o rQua rtc r + Rpt Period Op Hours Accumulator
Array for the Location > 168)
Set CurrentLinearityStatus = "OOC-Conditional Period Expired".
else if (PriorEventRecorcl. MaxOpHoursPriorQuartcr + Rpt Period Op Hours
Accumulator Array for the Location > 168)
Set CurrentLinearityStatus = "Undetermined-Conditional Data".
else
Set CurrentLinearityStatus = "IC-Conditional".
Results:
Result Response Severity
Environmental Protection Agency
Page 602 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Usage:
1
Process/Category:
Emissions Data Evaluation Report
C02 Linearity Status Evaluation
2
Process/Category:
Emissions Data Evaluation Report
Hg Linearity Status Evaluation
3
Process/Category:
Emissions Data Evaluation Report
NOX Linearity Status Evaluation
4
Process/Category:
Emissions Data Evaluation Report
02 Dry Linearity Status Evaluation
5
Process/Category:
Emissions Data Evaluation Report
02 Wet Linearity Status Evaluation
6
Process/Category:
Emissions Data Evaluation Report
S02 Linearity Status Evaluation
Environmental Protection Agency
Page 603 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
LINSTAT-6
Check Name:
Determine Final Linearity Status
Related Former Checks:
Applicability:
Description:
Specifications:
Set AlternateLinearityRecord = null
Set AlternatelnvalidLinearityRecord = null
if {CurrentLinearityStatus begins with "OOC")
if (InvalidLinearityRecord is not null)
Set CurrentLinearityStatus = CurrentLinearity Status &
Return result CurrentLinearityStatus.
else if (CurrentLinearityStatus= "Invalid Monitor Span")
if (CurrentAnalyzerRangeUsed = "H")
Set CurrentLinearityStatus = CurrentLinearityStatus & " (High Scale)".
else
Set CurrentLinearityStatus = CurrentLinearityStatus & " (Low Scale)".
Return result CurrentLinearityStatus.
else if (DualRangeStatus = true and CurrentLinearityStatus begins with "IC" or "Undetermined")
if (CurrentAnalyzerRangeUsed = "H")
Set AlternateAnalyzerRange = "L".
Set AlternateComponentID = LowRangeComponentlD.
else
Set AlternateAnalyzerRange = "H".
Set AlternateComponentID = HighRangeComponentlD.
for each record in MonitorSystemComponentRecordsByHourLocation where the ComponentID is equal to the
AlternateComponentID
Append MonitorSystemComponentRecordsByHourLocation. Sy stcmID to AlternateSystemlDs.
if (MonitorSystemComponentRecordsByHourLocation is not found)
Set CurrentLinearityStatus = "Invalid Monitor System Component".
Return result CurrentLinearityStatus.
if (CurrentMHVParameter in set {S02C, NOXC})
Locate the record in MonitorSpanRecordsByHourAndLocation for the hour where the ComponentTypeCode is equal to
the QaStatusComponentTypeCode and the SpanScaleCode is equal to the AlternateAnalyzerRange.
if (MonitorSpanRecordsByHourAndLocation is not found OR more than one MonitorSpanRecordsByHourAndLocation
Environmental Protection Agency
Page 604 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
is found or MonitorSpanRecordsByHourAndLocation.SparNahiQ is null or is less than or equal to 0)
Set CurrentlAnearityStatus = "Invalid Monitor Span",
if (AlternateAnalyzerRange = "H")
Set CurrentlAnearity Status = CurrentlAnearity Status & " (High Scale)".
else
Set CurrentlAnearity Status = CurrentlAnearityStatus & " (Low Scale)".
Return result CurrentlAnearityStatus.
else if (MonitorSpanRecordsByHourAndLocation.SpanVahie <=30)
If (CurrentlAnearityStatus does not begin with "IC")
Return result CurrentlAnearityStatus.
else
exit check.
Locate the most recent record in LinearityTestRecordsByLocationForQAStatus for the AlternateComponentID where the
SpanScaleCode is equal to the AlternateAnalyzerRange and the CalculatedTestResult is not equal to "INVALID" and the
EndDate/Hour is either:
a) prior to the CurrentDateHour OR
b) equal to the CurrentDateHour and the EndMinute is less than "45" and the CalculatedTestResult is equal to "PASSED" or
"PASSAPS".
if (Linearity TestRecordsByLocationForQAStatus is found)
Set AlternateLinearityRecord = the found record in Linearity TestRecordsByLocationForQAStatus.
Locate all records in QACertificationEventRecords where:
the ComponentID is equal to the AlternateComponentID
AND LinearityRequired is equal to "Y",
AND the QACertEventDate/Hour is either:
a) prior to the CurrentDateHour OR
b) equal to both the CurrentDateHour and the ConditionalDataBeginDate/Hour;
AND either
a) AlternateLinearityRecord is null OR
b) QACertEventDate/Hour is after the A Item ate I. in earity Record. EndDate/Hour OR
c) QACertEventDate/Hour is equal to the AltemateLinearity Record.EndDMc/Hour AND (TestCompletionDate is null or the
TestCompletionDate/Hour is after the A Item ateL in earity Record. EndDate/Hour)
AND either
a) DualRangeStatus = false OR
b) HighRangeComponentID <> LowRangeComponentID OR
c) QACertEventCode <> 27 or 30 or 172 and AlternateAnalyzerRange = "H" OR
d) QACertEventCode <> 35 or 171 and AlternateAnalyzerRange = "L"
if (QACertificationEventRecords is found)
Environmental Protection Agency
Page 605 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
if ((>/4C.'6'/*?i/i«/?iVw£'v'6'rt?/?6'cwY/.s.ConditionalBcginDatc/Hour is null or CurrentDateHour is prior to the
QACertificationEventRecords.ConditiomSSQgmD&tQrRom)
If (CurrentLinearityStatus does not begin with "IC")
Return result CurrentLinearityStatus.
Locate the most recent record in Linearity TestRecordsByLocationForQAStatus for the AlternateComponentID
where the SpanScaleCode is equal to the. I1 tenia te. InalyzerRange, the CalculatedTestResult is equal to
"INVALID", and the EndDate/Hour is after the OA Certification E ventRecords. Q A Cc rt E v e n t D a tc/ H o u r and prior
to the CurrentDateHour.
if (Linearity TestRecordsByLocationForQAStatus is found)
Set AlternatelnvalidLinearityRecord = the found record in
Linearity TestRecordsByLocationForQAStatus.
else
Set AlternatelnvalidLinearityRecord = null.
Locate the first record in Linearity TestRecordsByLocationForQAStatus where the ComponentID is equal to the
AlternateComponentID,the SpanScaleCode is equal to the. 11 tern ate. InalyzerRangelhc CalculatedTestResult is
not equal to "INVALID", and the EndDate/Hour is on or after the
QACertificationEventRecords.ConditiomlDataBeginDate/Hour.
if (Linearity TestRecordsByLocationForQAStatus is found)
Set AlternateLinearityRecord = the found record in LinearityTestRecordsByLocationForQAStatus.
if (AlternateLinearityRecord .QANeedsEvaluationFlag = "Y")
Set CurrentLinearityStatus = "Alternate Range Recertification Test Not Yet Evaluated".
else if (AlternateLinearityRecord .TestResultCode is null or is in set {FAILED, ABORTED})
If (AlternatelnvalidLinearityRecord is null)
Locate the most recent record in LinearityTestRecordsByLocationForQAStatus for the
AlternateComponentID where the SpanScaleCode is equal to the
AlternateAnalyzerRange, the CalculatedTestResult is equal to "INVALID", and the
EndDate/Hour is after the QACertificationEventRecords.QACertEyentDate/Hour and
prior to the EndDate/Hour of the LinearityTestRecordsByLocationForQAStatus record
retrieved above.
if (Linearity TestRecordsByLocationForQAStatus is found)
Set AlternatelnvalidLinearityRecord = the found record in
Linearity TestRecordsByLocationForQAStatus.
if (AlternateLinearityRecord .TestResultCode is null)
Set CurrentLinearityStatus = "OOC-Alternate Range Recertification Test Has Critical
Errors".
if (AlternatelnvalidTestRecord is not null)
Set CurrentLinearityStatus = CurrentLinearityStatus &
else if (AlternateLinearityRecord .TestResultCode = "FAILED")
Set CurrentLinearityStatus = "OOC-Alternate Range Recertification Test Failed",
if (AlternatelnvalidTestRecord is not null)
Set CurrentLinearityStatus = CurrentLinearityStatus &
else if (AlternateLinearityRecord .TestResultCode = "ABORTED")
Set CurrentLinearityStatus = "OOC-Alternate Range Recertification Test Aborted",
if (AlternatelnvalidTestRecord is not null)
Environmental Protection Agency
Page 606 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
Set CurrentLinearityStatus = CurrentLinearityStatus &
If (CurrentLinearityStatus does not begin with "IC")
Return result CurrentLinearityStatus.
else
else
if (A Item ateL in earity Record is found)
if (AltemateIJnearityRecord.QANccdsEvi\\ui\tionFk\g = "Y")
Set CurrentLinearityStatus = "Alternate Range Test Not Yet Evaluated".
else if (A Item ateL in earity Record. TestResultCode is null or is in set {ABORTED, FAILED})
Locate the most recent record in Linearity TestRecordsByLocationForQAStatus for the
AlternateComponentID where the SpanScaleCode is equal to the AlternateAnalyzerRange and the
EndDate/Hour is prior to the CurrentDateHour and the EndDate/Hour is greater than the
A Item at el. in earity Record. E nd D a tc/ H o u r and the CalculatedTestResult is equal to "INVALID".
if (LinearityTestRecordsByLocationForQAStatus is found)
Set AlternatelnvalidLinearityRecord = the found record in
Linearity TestRecordsByLocationForQAStatus.
if (AlternateLinearityRecord .TestResultCode = null)
Set CurrentLinearityStatus = "OOC-Alternate Range Test Has Critical Errors",
if (AlternatelnvalidLinearityRecord is not null)
Set CurrentLinearityStatus = CurrentLinearityStatus &
else if {AlternateLinearityRecord TestResultCode = "FAILED")
Set CurrentLinearityStatus = "OOC-Alternate Range Test Failed",
if (AlternatelnvalidLinearityRecord is not null)
Set CurrentLinearityStatus = CurrentLinearityStatus &
else if (AlternateLinearityRecord TestResultCode = "ABORTED")
Set CurrentLinearityStatus = "OOC-Alternate Range Test Aborted",
if (AlternatelnvalidLinearityRecord is not null)
Set CurrentLinearityStatus = CurrentLinearityStatus &
else
Set CurrentLinearityStatus = "OOC-No Prior Alternate Range Test or Event".
If (CurrentLinearityStatus does not begin with "IC")
Return result CurrentLinearityStatus.
If (CurrentLinearityStatus does not begin with "IC")
Return result CurrentLinearityStatus.
Environmental Protection Agency
Page 607 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
Alternate Range
Recertification
Test Not Yet
Evaluated
Alternate Range
Test Not Yet
Evaluated
Invalid
Certification
Event
Invalid Monitor
Span (High
Scale)
Invalid Monitor
Span (Low Scale)
Invalid Monitor
System
Invalid Monitor
System
Component
Invalid Op Data
Missing Op Data
Missing Program
OOC-Alternate
Range
Recertification
Test Aborted
OOC-Alternate
Range
Recertification
Test Aborted*
OOC-Alternate
Range
Recertification
Test Failed
OOC-Alternate
Range
Recertification
Test Failed*
OOC-Alternate
Range
Recertification
Test Has Critical
Errors
OOC-Alternate
Range
Recertification
Test Has Critical
Errors*
Response Severity
The [testtype] status for [key] could not be determined, because the prior [testtype] for Critical Error Level 1
the alternate range component with TestNumber [alttestnum] has not yet been
evaluated.
The [testtype] status for [key] could not be determined, because the prior [testtype] for
the alternate range component with TestNumber [alttestnum] has not yet been
evaluated.
The [testtype] status for [key] could not be determined, because the QA Certification
Event record for QACertEventCode [code] QACertEventDate [eventdate] has a critical
error.
The [testtype] status for [key] could not be determined, because you did not report a
single, valid high-scale [comptype] span record that was active during the test.
The [testtype] status for [key] could not be determined, because you did not report a
single, valid low-scale [comptype] span record that was active during the test.
The [testtype] status for [key] could not be determined, because the Monitor System
record for MonitoringSystemID [system] has a critical error.
The [testtype] status for [key] could not be determined, because you did not report any
active Monitor System Component records for the alternate range of the component.
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
The [testtype] status for [key] could not be determined, because the OperatingTime in at Critical Error Level 1
least one Hourly Operating Data records was missing or invalid.
The [testtype] status for [key] could not be determined, because the Op Supp Data Critical Error Level 1
record for OPHOURS, OSHOURS, or OPDAYS is missing for
[MISSINGOPDATAINFO] (and possibly other previous reporting periods). If you
have submitted emissions data for prior quarters, you should be able to retrieve these
records by logging on to the EPA host.
The [testtype] status for [key] could not be determined, because a Unit Program record Critical Error Level 1
associated with the initial certification event for QACertEventCode [code]
QACertEventDate [eventdate] either does not exist or has a
UnitMonitorCertificationBeginDate inconsistent with the BeginDate of the associated
Monitor System record.
The subsequent recertification [testtype] for the alternate range of the component for Critical Error Level 1
[key] with TestNumber [alttestnum] was aborted.
The subsequent recertification [testtype] for the alternate range of [key] with Critical Error Level 1
TestNumber [alttestnum] was aborted. An invalid [testtype] with TestNumber
[altinvtestnum] was ignored.
The subsequent recertification [testtype] for the alternate range of the component for Critical Error Level 1
[key] with TestNumber [alttestnum] failed.
The subsequent recertification [testtype] for the alternate range of the component for Critical Error Level 1
[key] with TestNumber [alttestnum] failed. An invalid [testtype] with TestNumber
[altinvtestnum] was ignored.
The subsequent recertification [testtype] for the alternate range of the component for Critical Error Level 1
[key] with TestNumber [alttestnum] has critical errors.
The subsequent recertification [testtype] for the alternate range of the component for Critical Error Level 1
[key] with TestNumber [alttestnum] has critical errors. An invalid [testtype] with
TestNumber [altinvtestnum] was ignored.
Environmental Protection Agency
Page 608 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
OOC-Alternate
Range Test
Aborted
OOC-Alternate
Range Test
Aborted*
OOC-Alternate
Range Test
Failed
OOC-Alternate
Range Test
Failed*
OOC-Alternate
Range Test Has
Critical Errors
OOC-Alternate
Range Test Has
Critical Errors*
OOC-Conditional
Period Expired
OOC-Conditional
Period Expired*
OOC-Event
OOC-Event*
OOC-Expired
OOC-Expired*
OOC-No Prior
Alternate Range
Test or Event
OOC-No Prior
Test or Event
OOC-No Prior
Test or Event*
OOC-Recertificat
ion Test Aborted
OOC-Recertificat
ion Test
Aborted*
OOC-Recertificat
ion Test Failed
OOC-Recertificat
ion Test Failed*
OOC-Recertificat
ion Test Has
Critical Errors
OOC-Recertificat
ion Test Has
Critical Errors*
OOC-Test
Aborted
OOC-Test
Aborted*
OOC-Test Failed
OOC-Test
Failed*
The prior [testtype] for the alternate range of the component for [key] with TestNumber Critical Error Level
[alttestnum] was aborted.
The prior [testtype] for the alternate range of the component for [key] with TestNumber Critical Error Level
[alttestnum] was aborted. An invalid [testtype] with TestNumber [altinvtestnum] was
ignored.
The prior [testtype] for the alternate range of the component for [key] with TestNumber Critical Error Level
[alttestnum] failed.
The prior [testtype] for the alternate range of the component for [key] with TestNumber Critical Error Level
[alttestnum] failed. An invalid [testtype] with TestNumber [altinvtestnum] was ignored.
The prior [testtype] for the alternate range of the component for [key] with TestNumber Critical Error Level
[alttestnum] has critical errors.
The prior [testtype] for the alternate range of the component for [key] with TestNumber
[alttestnum] has critical errors. An invalid [testtype] with TestNumber [altinvtestnum]
was ignored.
The conditional data period for QACertEventCode [code] QACertEventDate
[eventdate] for [key] has expired.
The conditional data period for QACertEventCode [code] QACertEventDate
[eventdate] for [key] has expired. An invalid [testtype] was ignored.
You reported a QA Certification Event record for QACertEventCode [code]
QACertEventDate [eventdate], but you did not indicate the use of conditional data for
[key].
You reported a QA Certification Event record for QACertEventCode [code]
QACertEventDate [eventdate] for [key], but you did not indicate the use of conditional
data. An invalid [testtype] was ignored.
The prior [testtype] for [key] with TestNumber [testnum] has expired.
The prior [testtype] for [key] with TestNumber [testnum] has expired. An invalid prior
[testtype] with TestNumber [invtestnum] was ignored.
You did not report a prior [testtype] or certification event for the alternate range of the
component for [key].
You did not report a prior [testtype] or certification event for [key].
You did not report a valid prior [testtype] or certification event for [key]. An invalid
[testtype] with TestNumber [invtestnum] was ignored.
The subsequent recertification [testtype] for [key] with TestNumber [subtestnum] was
aborted.
The subsequent recertification [testtype] for [key] with TestNumber [subtestnum] was
aborted. An invalid [testtype] with TestNumber [invtestnum] was ignored.
Critical
Error Level 1
Critical
Error Level 1
Critical
Error Level 1
Critical
Error Level 1
Critical
Error Level 1
Critical
Error Level 1
Critical
Error Level 1
Critical
Error Level 1
Critical
Error Level 1
Critical
Error Level 1
Critical
Error Level 1
Critical
Error Level 1
The subsequent recertification [testtype] for [key] with TestNumber [subtestnum] Critical Error Level
failed.
The subsequent recertification [testtype] for [key] with TestNumber [subtestnum] Critical Error Level
failed. An invalid [testtype] with TestNumber [invtestnum] was ignored.
The subsequent recertification [testtype] for [key] with TestNumber [subtestnum] has Critical Error Level
critical errors.
The subsequent recertification [testtype] for [key] with TestNumber [subtestnum] has Critical Error Level
critical errors. An invalid [testtype] with TestNumber [invtestnum] was ignored.
The applicable prior [testtype] for [key] with TestNumber [testnum] was aborted. Critical Error Level
The prior [testtype] for [key] with TestNumber [testnum] was aborted. An invalid prior Critical Error Level
[testtype] with TestNumber [invtestnum] was ignored.
The applicable prior [testtype] for [key] with TestNumber [testnum] failed. Critical Error Level
The prior [testtype] for [key] with TestNumber [testnum] failed. An invalid prior Critical Error Level
[testtype] with TestNumber [invtestnum] was ignored.
Environmental Protection Agency
Page 609 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
OOC-Test Has
Critical Errors
OOC-Test Has
Critical Errors*
Prior Test Not
Yet Evaluated
Recertification
Test Not Yet
Evaluated
Undetermined-Co
nditional Data
The applicable prior [testtype] for [key] with TestNumber [testnum] has critical errors. Critical Error Level 1
The prior [testtype] for [key] with TestNumber [testnum] has critical errors. An invalid
prior [testtype] with TestNumber [invtestnum] was ignored.
The [testtype] status for [key] could not be determined, because the applicable prior
[testtype] with TestNumber [testnum] has not yet been evaluated.
The [testtype] status for [key] could not be determined, because the subsequent
recertification [testtype] for the component with TestNumber [subtestnum] has not yet
been evaluated.
The software could not determine if the current hour was within the conditional data
period for QACertEventCode [code] QACertEventDate [eventdate] for [key]
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Informational Message
Usage:
1
Process/Category:
Emissions Data Evaluation Report
C02 Linearity Status Evaluation
2
Process/Category:
Emissions Data Evaluation Report
Hg Linearity Status Evaluation
3
Process/Category:
Emissions Data Evaluation Report
NOX Linearity Status Evaluation
4
Process/Category:
Emissions Data Evaluation Report
02 Dry Linearity Status Evaluation
5
Process/Category:
Emissions Data Evaluation Report
02 Wet Linearity Status Evaluation
6
Process/Category:
Emissions Data Evaluation Report
S02 Linearity Status Evaluation
Environmental Protection Agency
Page 610 of 850
-------
Draft ECMPS Emissions Check Specifications
Check Category:
LME
6/17/2015 12:00:00AM
Environmental Protection Agency
Page 611 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
LME-11
Check Name:
Check LTFF System
Related Former Checks:
Applicability:
Description:
Specifications:
For the LTFF record:
If MonitoringSystemID is null,
return result A.
else
Locate the Monitor System record for the MonitoringSystemID.
If the associated SystemTypeCode is not equal to "LTOL" or "LTGS",
return result B.
Results:
Result
A
B
Response
You did not report a MonitoringSystemID in an LTFF record.
The MonitoringSystemID reported in the LTFF record for [key] is not a long-term fuel
flow system.
Severity
Fatal
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report — Long Term Fuel Flow
1
Process/Category: LME Emissions Data Generation LTFF Heat Input Data
1
Process/Category: Emissions Data Entry Screen Evaluation LTFF Data Evaluation
Environmental Protection Agency
Page 612 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
LME-13
Check Name:
Check Long Term Fuel Flow Value
Related Former Checks:
Applicability:
Description:
Specifications:
For the LTFF record:
If the LongTermFuelFlowValue is null or is less than or equal to 0,
return result A.
Results:
Result
A
Response
The [fieldname] reported in the LTFF record for [key] is missing or invalid.
Severity
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report — LongTermFuelFlow
1
Process/Category: LME Emissions Data Generation LTFF Heat Input Data
1
Process/Category: Emissions Data Entry Screen Evaluation LTFF Data Evaluation
Environmental Protection Agency
Page 613 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
Check Name:
Related Former Checks:
Applicability:
Description:
Specifications:
For the LTFF record:
If the LongTermFuelFlowUOMCode is null,
return result A.
Otherwise,
If the SystemTypeCode is "LTOL" and the LongTermFuelFlowUOMCode is not in set {"LB", "GAL"},
return result A.
If the SystemTypeCode is "LTGS" and the LongTermFuelFlowUOMCode is not equal to "SCF",
return result A.
Results:
Result Response Severity
A The [fieldname] reported in the LTFF record for [key] is missing or invalid. Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report — Long Term Fuel Flow
1 Process/Category: LME Emissions Data Generation LTFF Heat Input Data
1 Process/Category: Emissions Data Entry Screen Evaluation LTFF Data Evaluation
LME-14
Check Long Term Fuel Flow UOM
Environmental Protection Agency
Page 614 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
LME-15
Check Name:
Check LTFF GCV
Related Former Checks:
Applicability:
Description:
Specifications:
For the LTFF record:
If the GrossCalorificValue is null or is less than or equal to 0,
return result A.
Results:
Result
A
Response
The [fieldname] reported in the LTFF record for [key] is missing or invalid.
Severity
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report — Long Term Fuel Flow
1
Process/Category: LME Emissions Data Generation LTFF Heat Input Data
1
Process/Category: Emissions Data Entry Screen Evaluation LTFF Data Evaluation
Environmental Protection Agency
Page 615 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
LME-16
Check Name:
Check LTFF GCV UOM
Related Former Checks:
Applicability:
Description:
Validation Tables:
Fuel Type Reality Checks for GCV (Cross Check Table)
Fuel Type Warning Levels for GCV (Cross Check Table)
Fuel Type Reality Checks for GCV (Cross Check Table)
Fuel Type Warning Levels for GCV (Cross Check Table)
Fuel Type Reality Checks for GCV (Cross Check Table)
Fuel Type Warning Levels for GCV (Cross Check Table)
Specifications:
For the LTFF record:
LME Gen LTFF Heat Input = null.
If the GCVUnitsOfMeasureCode is null,
return result A.
Otherwise,
If the LongTermFuelFlowUOMCode is "LB" and the GCVUnitsOfMeasureCode is not equal to "BTULB",
return result A.
If the LongTermFuelFlowUOMCode is "GAL" and the GCVUnitsOfMeasureCode is not equal to "BTUGAL",
return result A.
If the LongTermFuelFlowUOMCode is "SCF" and the GCVUnitsOfMeasureCode is not equal to "BTUSCF",
return result A.
Otherwise,
If GrossCalorificValue is greater than 0 and LongTermFuelFlowValue is greater than 0,
Calculate LME Gen LTFF Heat Input = GrossCalorific Value * LongTermFuelFlowValue / 1,000,000,
rounded to the nearest integer.
Max Expected GCV = Lookup "Upper Value" in "Fuel Type Warning Levels for GCV Cross Check Table"
where "Fuel Code - Units Of Measure" column = concatenation of (FuelCode," -",
LongTermFuelFlowUOMCode)
Min Expected GCV = Lookup "Lower Value" in "Fuel Type Warning Levels for GCV Cross Check Table"
where "Fuel Code - Units Of Measure" column = concatenation of (FuelCode," -",
LongTermFuelFlowUOMCode)
Max Allowed GCV = Lookup "Upper Value" in "Fuel Type Reality Checks for GCV Cross Check Table"
where "Fuel Code - Units Of Measure" column = concatenation of (FuelCode," -",
LongTermFuelFlowUOMCode)
Min Allowed GCV = Lookup "Lower Value" in "Fuel Type Reality Checks for GCV Cross Check Table"
where "Fuel Code - Units Of Measure" column = concatenation of (FuelCode," -",
LongTermFuelFlowUOMCode)
if {Max Allowed GCV is not null AND GrossCalorific Value > Max Allowed GCV) OR {Min Allowed GCV is not
null AND GrossCalorificValue < Min Allowed GCV)
return result B
else
if {Min Expected GCV is not null AND GrossCalorificValue < Min Expected GCV) OR {Max Expected
GCV is not null AND GrossCalorificValue > Max Expected GCV)
return result C
Environmental Protection Agency
Page 616 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
A
B
C
Usage:
1
Response
The [fieldname] reported in the LTFF record for [key] is missing or invalid.
The GrossCalorificValue reported in the long-term fuel flow record for [key] is outside
the range of allowable values for the fuel type [fueled].
The GrossCalorific Value reported in the long-term fuel flow record for [key] is outside
the range of expected values for the fuel type [fueled].
Process/Category: Emissions Data Evaluation Report — Long Term Fuel Flow
Severity
Critical Error Level 1
Critical Error Level 1
Non-Critical Error
1 Process/Category: LME Emissions Data Generation LTFF Heat Input Data
1 Process/Category: Emissions Data Entry Screen Evaluation LTFF Data Evaluation
Environmental Protection Agency
Page 617 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: LME-41
Check Name: Check LTFF Fuel Flow Period Code
Related Former Checks:
Applicability:
Description:
Specifications:
For the LTFF record:
If LME OS is equal to true,
If the Quarter of the Current Reporting Period is equal to 2,
If the FuelFlowPeriodCode is null,
return result A.
Otherwise,
If the FuelFlowPeriodCode is not null,
return result B.
Otherwise,
If the FuelFlowPeriodCode is not null,
return result C.
Results:
Result
A
B
C
Usage:
1
Response Severity
You did not report a FuelFlowPeriodCode in the LTFF record for [key]. This value is Critical Error Level 1
required for LME units with an ozone-season qualification during the second quarter.
You reported a FuelFlowPeriodCode in the LTFF record for [key], but this value is only Critical Error Level 1
appropriate during the second quarter.
You reported a FuelFlowPeriodCode in the LTFF record for [key], but this value is only Critical Error Level 1
appropriate for LME units with an ozone-season qualification.
Process/Category: Emissions Data Evaluation Report — Long Term Fuel Flow
Environmental Protection Agency
Page 618 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
LME-42
Check Name:
Check LTFF Total Heat Input
Related Former Checks:
Applicability:
Description:
Validation Tables:
Hourly Emissions Tolerances (Cross Check Table)
Specifications:
For the Current LTFF record:
If LME Gen LTFF Heat Input is not null,
If LME Total Heat Input Array for the location is greater than or equal to 0,
add LME Gen LTFF Heat Input to LME Total Heat Input Array for the location.
If LME OS is true and the Current LTFF . F lie 1F1 o w Pc ri o dC o dc is equal to "A",
add LME Gen LTFF Heat Input to LME April Total Heat Input Array for the location.
If (the LocationName begins with "CP")
If LME CP Total Heat Input is greater than or equal to 0,
add LME Gen LTFF Heat Input to LME CP Total Heat Input.
If LME OS is true and the Current LTFF . F lie 1F1 o w P c ri o dC o dc is equal to "A",
add LME Gen L TFF Heat Input to LME CP April Heat Input.
Set LME Total Heat Input Array for the location to -1.
If (the LocationName begins with "CP")
set LME CP Total Heat Input to -1.
If (the LocationName begins with "CP")
Rpt Period HI Calculated Accumulator Array for this location = LME Total Heat Input Array for the location.
April HI Calculated Accumulator Array for this location = LME Total April Input Array for the location
Expected Summary Value HI Array for this location = true
If Current LTFF Record J otalHcatlnput is greater than or equal to 0,
If (the LocationName begins with "CP" AND Rpt Period HI Reported Accumulator Array for this location is greater than
or equal to 0)
Rpt Period HI Reported Accumulator Array for this location = Rpt Period HI Reported Accumulator Array for
this location + Current /. TFF Record.To ta 1Hca 11 nput
If LME Gen LTFF Heat Input is not null AND Current LTFF Record. To ta 1H ca 11 n p u t is not equal to LME Gen LTFF
Heat Input,
Heat Input Tolerance = Lookup Tolerance from Cross-Check Table "Hourly Emissions Tolerances" where
Parameter = "HI" AND
UOM = "MMBTUHR"
else
if (ABS(Current LTFF Record. To t a 1H ca 11 n p u t - LME Gen LTFF Heat Input) > Heat Input Tolerance)
return result A.
else
If (the LocationName begins with "CP")
Rpt Period HI Reported Accumulator Array for this location= -1.
return result B
Environmental Protection Agency
Page 619 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result Response Severity
A The TotalHeatlnput reported in the LTFF record for [key] is inconsistent with the Critical Error Level 1
recalculated value.
B The [fieldname] reported in the LTFF record for [key] is missing or invalid. Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report — Long Term Fuel Flow
Environmental Protection Agency
Page 620 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: LME-10
Check Name: Determine Total Load for Reporting Period
Related Former Checks:
Applicability:
Description:
Specifications:
Set LME Gen LTFF Heat Input Array, LME Gen Total Heat Input Array, LME Gen Total Load Array, LME Gen Total S02M Array,
LME Gen Total NOXM Array, LME Gen Total C02M Array, LME Gen Total Op Time Array, LME Gen Total Op Hours Array, and
LME Gen LTFF Total Op Time Array to 0 for each location in the monitor configuration.
Set LME Gen LTFF April Heat Input Array, LME Gen April Heat Input Array, LME Gen April Load Array, LME Gen April NOXM
Array, LME Gen April Op Time Array, LME Gen April Op Hours Array, and LME Gen L TFF April Op Time Array to 0 for each
location in the monitoring configuration.
Set LME Gen CP Total Heat Input, LME Gen Total Load, and LME Gen Total Optime to 0.
Set LME Gen CP April Heat Input, LME Gen April Load, and LME Gen April Optime to 0.
Set LME Gen Annual and LME Gen OS to false.
Set LME Gen HI Method and LME Gen HI Substitute Data Code to null.
Locate MonitorMethod records for all locations in the monitoring configuration where ParameterCode = "HIT", BeginDate is on or before
the first day of the reporting period, and the EndDate is null or is on or after the last day of the reporting period.
If any location does not have a retrieved record,
return result A.
Otherwise,
Set LME Year Start Quarter to the quarter of the current reporting period.
Locate a MonitorQualification for all units in the monitoring configuration where the QualificationTypeCode is equal to "LMEA"
or "LMES", BeginDate is on or before the last day of the reporting period, and the EndDate is null or is on or after December 31 cf
the year prior to the reporting period.
If a record with QualificationTypeCode equal to "LMEA" is found,
set LME Gen Annual to true.
If a record with QualificationTypeCode equal to "LMES" is found,
set LME Gen OS to true.
If LME Gen Annual AND LME Gen OS are both false,
return result B.
else if LME Gen Annual is false AND the Quarter of the reporting period is equal to 1 or 4,
return result C.
Otherwise,
If the Quarter of the reporting period is greater than 1,
If the earliest BeginDate in the retrieved records is in a year prior to the year of the current reporting period,
If LME Gen Annual is equal to true,
set LME Year Start Quarter to 1.
else
set LME Year Start Quarter to 2.
else if the earliest BeginDate in the retrieved records is in a quarter prior to the LME Year Start Quarter,
set LME Year Start Quarter to the quarter of the earliest BeginDate.
Environmental Protection Agency
Page 621 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
If MethodCode in all the retrieved Method records is equal to "MHHI",
LME Gen HI Method = 'MHHI".
Locate an LTFF record for any location during the reporting period.
If found,
return result D.
If MethodCode in all the retrieved Method records is in set {LTFF, CALC, LTFCALC},
LME Gen HI Method = "LTFF".
If SubstituteDataCode in any retrieved record is equal to "MHHI",
LME Gen HI Substitute Data Code = 'MHHI".
For each Hourly Op Data record for the configuration:
If Hourly Op DataHourLoad is not null and is less than 0,
return result E.
Hourly Op /Jafa. OpTime for any hour is null, less than 0, or greater than 1,
return result F.
Hourly Op /Jafa. OpTime is greater than 0 and Hourly Op /Jafa. HourLoad is null,
return result E.
Hourly Op /Jafa OpTime is greater than 0 AND Hourly Op DataMHRl Indicator is not equal to 1,
Add HourLoad * OpTime to LME Gen Total Load Array for the location.
Add HourLoad * OpTime to LME Gen Total Load.
Add OpTime to LME Gen Total Optime.
Add OpTime to LME Gen LTFF Total Op Time Array for location.
If the month of Hourly Op Data.Date is April AND LME Gen OS is equal to true,
Add HourLoad * OpTime to LME Gen April Load Array for the location.
Add HourLoad * OpTime to LME Gen April Load.
Add OpTime to LME Gen April Optime.
Add OpTime to LME Gen LTFF April Op Time Array for location
If LME Gen OS is equal to true and the Quarter of the reporting period is equal to 2,
Locate an LTFF record for any location in the monitoring configuration during the reporting period where
the FuelFlowPeriodCode is equal to "A".
If found and the LME Gen April Load is equal to 0 and LME Gen April Optime is equal to 0,
return result J.
Else if not found AND (LME Gen April Load is greater than 0 or LME Gen April Optime is greater than
1),
return result K.
Otherwise,
Locate an LTFF record for any location in the monitoring configuration during the reporting
period where the FuelFlowPeriodCode is equal to "MJ".
If found,
If {LME Gen Total Load - LME Gen April Load) is equal to 0 and (LME Gen Total
else if
else if
else if
Environmental Protection Agency
Page 622 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Optime - LME Gen April Optime) is equal to 0,
return result L.
If not found,
If (LME Gen Total Load - LME Gen April Load) is greater than 0 or {LME Gen Total
Optime - LME Gen April Optime) is greater than 1,
return result M.
Locate an LTFF record for any location in the monitoring configuration during the reporting period.
If LME Gen Total Load is equal to 0 and LME Gen Total Optime is equal to 0,
return result G.
If not found,
If LME Gen Total Load is greater than 0 or LME Gen Total Optime is greater than 1,
return result I.
Otherwise,
If found,
Otherwise,
return result H.
Do not process remaining categories if fatal error is returned.
Environmental Protection Agency
Page 623 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
A
B
C
D
E
F
G
H
I
J
K
L
M
Usage:
1
Response
You have not reported an active HIT method in your monitoring plan for at least one
monitoring location in the configuration.
You have not reported an active LMEA or LMES qualification record for this
configuration in your monitoring plan.
You have not reported an active LMEA qualification record for this configuration in
your monitoring plan, but the reporting period is the first or fourth quarter. Only annual
LME units should report in the first or fourth quarter.
You have reported MHHI as the heat input method for this configuration, but you have
reported a long-term fuel flow record.
You have reported LTFF as the heat input method for this configuration, but the
LoadValue in at least one hourly record is missing or invalid.
You have reported LTFF as the heat input method for this configuration, but the
OperatingTime in at least one hourly record is missing or invalid.
You have reported a long-term fuel flow record for this reporting period, but the sum of
the load and operating time values in the hourly records (where MHHIIndicator is not
equal to 1) are equal to 0.
You have not reported the same heat input method in your monitoring plan for all
locations in the configuration during the reporting period.
You have reported LTFF as the heat input method for this configuration, but you have
not reported a long-term fuel flow record for this reporting period.
You have reported a long-term fuel flow record for April, but the sum of the load and
operating time values in the hourly records (where MHHIIndicator is not equal to 1) are
equal to 0.
You have reported LTFF as the heat input method for this ozone-season reporting
configuration, but you have not reported a long-term fuel flow record for April.
You have reported a long-term fuel flow record for May and June, but the sum of the
load and operating time values in the hourly records (where MHHIIndicator is not equal
to 1) are equal to 0.
You have reported LTFF as the heat input method for this ozone-season reporting
configuration, but you have not reported a long-term fuel flow record for May/June.
Process/Category: LME Emissions Data Generation LME Initialization
Severity
Fatal
Fatal
Fatal
Fatal
Fatal
Fatal
Fatal
Fatal
Critical Error Level 1
Fatal
Critical Error Level 1
Fatal
Critical Error Level 1
Environmental Protection Agency
Page 624 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: LME-12
Check Name: Check LTFF Fuel Flow Period Code
Related Former Checks:
Applicability:
Description:
Specifications:
For the LTFF record:
If LME Gen OS is equal to true,
If the Quarter of the reporting period is equal to 2,
If the FuelFlowPeriodCode is null,
return result A.
Otherwise,
If the FuelFlowPeriodCode is not null,
return result B.
Otherwise,
If the FuelFlowPeriodCode is not null,
return result C.
Results:
Result
A
B
C
Usage:
1
Response Severity
You did not report a FuelFlowPeriodCode in the LTFF record for [key]. This value is Critical Error Level 1
required for LME units with an ozone-season qualification during the second quarter.
You reported a FuelFlowPeriodCode in the LTFF record for [key], but this value is only Critical Error Level 1
appropriate during the second quarter.
You reported a FuelFlowPeriodCode in the LTFF record for [key], but this value is only Critical Error Level 1
appropriate for LME units with an ozone-season qualification.
Process/Category: LME Emissions Data Generation LTFF Heat Input Data
Environmental Protection Agency
Page 625 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
LME-17
Check Name:
Check LTFF Total Heat Input
Related Former Checks:
Applicability:
Description:
Specifications:
For the LTFF record:
If LME Gen LTFF Heat Input is not null and is greater than or equal to 0 ,
if LME Gen Total Heat Input Array for the location is greater than or equal to 0,
add LME Gen L TFF Heat Input to LME Gen L TFF Heat Input Array for the location.
If LME Gen OS is true and the FuelFlowPeriodCode is equal to "A",
add LME Gen L TFF Heat Input to LME Gen L TFF April Heat Input Array for the location.
If Location is a common pipe,
If LME Gen CP Total Heat Input is greater than or equal to 0,
add LME Gen LTFF Heat Input to LME Gen CP Total Heat Input.
If LME Gen OS is true and the FuelFlowPeriodCode is equal to "A",
add LME Gen L TFF Heat Input to LME Gen CP April Heat Input.
Otherwise,
If Location is a common pipe,
set LME Gen CP Total Heat Input to -1.
Set LME Gen L TFF Heat Input Array for the location to -1.
Results:
Result
A
Response
obsolete
Severity
No Errors
Usage:
1 Process/Category: LME Emissions Data Generation LTFF Heat Input Data
Environmental Protection Agency
Page 626 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: LME-21
Check Name: Locate Hourly Op Record for LME Unit
Related Former Checks:
Applicability:
Description:
Specifications:
Set Current LME Hourly Op Record to null.
Set Generate LME to false.
If LME Gen Annual = true
Locate all Monitor Method records for the unit and the hour where the ParameterCode is equal to "S02M", "NOXM", or "C02M",
and the MethodCode is equal to "LME".
else
Locate all Monitor Method records for the unit and the hour where the ParameterCode is equal to "NOXM and the MethodCode is
equal to "LME".
If found,
Set LME Gen Parameters to the list of ParameterCodes in the retrieved records.
Otherwise,
Set LME Gen Parameters to null.
Locate an Hourly Op Data record for the unit and the hour.
If found,
If LME Gen Parameters is null,
return result A.
else
Set Current LME Hourly Op Record to the retrieved record.
Set Generate LME to true.
if LME Gen Annual is equal to false, and the current date is in the month of April,
return result B.
Otherwise,
If LME Gen Parameters is not null, AND
(LME Gen Annual is equal to true OR the current date is in the months of May thru September),
return result C.
Results:
Result
A
B
C
Response Seventy
There is no active LME method in your monitoring plan. Critical Error Level 1
You reported an LME Hourly record for April, but the unit does not have an annual Informational Message
LME qualification. Emissions for this hour will not be included in the totals reported in
the Summary Value record.
You did not report an LME Hourly record for the hour. Critical Error Level 1
Environmental Protection Agency
Page 627 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
Usage:
1 Process/Category: LME Emissions Data Generation Hourly Emissions Data
Environmental Protection Agency
Page 628 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
LME-22
Check Name:
Check LME Op Time
Related Former Checks:
Applicability:
Description:
Specifications:
If Current LME Hourly Op Record is not null,
If OpTime is null, or is not between 0 and 1 inclusive,
Set LME Gen Total Op Time Array for location to -1, Generate LME to false, and return result A.
Otherwise,
If OpTime is greater than 0, AND LME Gen Total Op Time Array for location is greater than or equal to 0,
Add 1 to LME Gen Total Op Hours Array for location.
Add OpTime to LME Gen Total Op Time Array for location.
If current date in the month of April,
Add 1 to LME Gen April Op Hours Array for location.
Add OpTime to LME Gen April Op Time Array for location.
Results:
Result
A
Response
The [fieldname] reported in the LME Hourly record is missing or invalid.
Severity
Critical Error Level 1
Usage:
1 Process/Category: LME Emissions Data Generation Hourly Emissions Data
Environmental Protection Agency
Page 629 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
LME-24
Check Name:
Check LME Load Value
Related Former Checks:
Applicability:
Description:
Specifications:
If Current LME Hourly Op Record is not null,
If LoadValue is less than 0,
set Generate LME to false, and return result A.
else if LoadValue is null,
If OperatingTime is greater than 0,
If LME Gen HI Method is equal to "LTFF"
set Generate LME to false, and return result B.
Otherwise
return result C.
else
If OperatingTime is equal to 0,
return result D.
Results:
Result
Response
The [fieldname] reported in the LME Hourly record is invalid.
You did not report a LoadValue in the LME Hourly record.
You did not report a LoadValue in the LME Hourly record.
You reported a LoadValue in the LME Hourly record. This field should be blank for a
non-operating hour.
Severity
A
B
C
D
Critical Error Level 1
Critical Error Level 1
Non-Critical Error
Critical Error Level 1
Usage:
1 Process/Category: LME Emissions Data Generation Hourly Emissions Data
Environmental Protection Agency
Page 630 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
LME-26
Check Name:
Check LME Load UOM
Related Former Checks:
Applicability:
Description:
Specifications:
If Current LME Hourly Op Record is not null,
If LoadValue is null,
If LoadUOMCode is not null,
return result A.
Otherwise,
If LoadUOMCode is not equal to "MW", "KLBHR", or "MMBTUHR",
set Generate LME to false, and return result A.
Otherwise,
Locate Monitor Load record for the location and hour.
If not found, or more than one record is found, or the MaximumLoadUnitsOfMeasureCode is null,
set Generate LME to false, and return result B.
Otherwise,
If the LoadUOMCode is not equal to the MaximumLoadUnitsOfMeasureCode in the retrieved record,
set Generate LME to false, and return result C.
Results:
Result
A
B
Response
The [fieldname] reported in the LME Hourly record is missing or invalid.
You have not reported a single, active, valid Monitor Load record in your monitoring
plan.
The LoadUOMCode in the LME Hourly record is not consistent with the value in the
Monitor Load record in your monitoring plan.
Severity
Critical Error Level 1
Critical Error Level 1
C
Critical Error Level 1
Usage:
1 Process/Category: LME Emissions Data Generation Hourly Emissions Data
1
Process/Category: Emissions Data Entry Screen Evaluation Hourly Op Data Evaluation
Environmental Protection Agency
Page 631 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: LME-27
Check Name: Check LME Fuel Code List
Related Former Checks:
Applicability:
Description:
Specifications:
If Current LME Hourly Op Record is not null,
If OpTime is greater than 0, and FuelCodeList is null,
set Generate LME to false, and return result A.
Results:
Result Response Severity
A You did not report a value in the FuelCodeList in the LME Hourly record, but the unit Critical Error Level 1
operated during the hour.
Usage:
1 Process/Category: LME Emissions Data Generation Hourly Emissions Data
1 Process/Category: Emissions Data Entry Screen Evaluation Hourly Op Data Evaluation
Environmental Protection Agency
Page 632 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: LME-28
Check Name: Calculate Heat Input for LME Unit
Related Former Checks:
Applicability:
Description:
Specifications:
LME Gen Heat Input Record = null
LME Calc Heat Input = null
LME Gen Fuel Code = null
If Generate LME is equal to true,
If Current LME Hourly Op Record. OperatingTime is greater than 0,
If LME Gen HI Method is equal to "MHHI" or Current LME Hourly Op Record. IVIH H11 ndica to r is equal to 1,
Locate all Monitor Default records for the hour and location where the ParameterCode is equal to "MHHI".
If one record is found, the DefaultValue is greater than 0, and the DefaultUnitsOfMeasureCode is equal to
"MMBTUHR".
Calculate LME Calc Heat Input = DefaultValue * Current LME Hourly Op Record.OpTime, rounded to
one decimal place.
Otherwise,
If LME Gen Parameters contains "S02M",
set LME Gen Total S02MArray for location to -1.
If LME Gen Parameters contains "NOXM",
set LME Gen Total NOXM Array for location to -1.
If LME Gen Parameters contains "C02M",
set LME Gen Total C02M Array for location to -1.
set LME Gen Total Heat Input Array for location to -1, and return result A.
else if LME Gen HI Method is equal to "LTFF",
If LME Gen CP Total Heat Input is greater than or equal to 0, LME Gen Total Heat Input Array for the location
is greater than or equal to 0, AND Current LME Hourly Op Record. HonrLoad is greater than or equal to 0,
If LME Gen OS is equal to true, and the Quarter of the reporting period is equal to 2,
If the current date is in the month of April,
if LME Gen April Load is greater than 0,
If Current LME Hourly Op Record.HourLoad is equal to 0
Set LME Calc Heat Input = 0
else
Calculate LME Calc Heat Input = (LME Gen CP April Heat Input *
Current LME Hourly Op Record.HourLoad * Current LME Hourly Op
Record. OpTime / LME Gen April Load) + (LME Gen LTFF April
Heat Input Array for the location * Current LME Hourly Op
Record .HouxLo'dA * Current LME Hourly Op Record .OpTime / LME
Gen April Load Array for the location), and round the result to 1
decimal place.
else if LME Gen April Optime is greater than 0,
Environmental Protection Agency
Page 633 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Calculate LME Calc Heat Input = (LME Gen CP April Heat Input * Current
LME Hourly Op Record:OpTime / LME Gen April Optime) + {LME Gen
LTFF April Heat Input Array for the location * Current LME Hourly Op
Record. OpTime / LME Gen LTFF April Op Time Array for the location), and
round the result to 1 decimal place.
Otherwise,
if LME Gen Total Load is greater than 0,
If Current LME Hourly Op Record. HourLoad is equal to 0,
Set LME Calc Heat Input = 0
else
Calculate LME Calc Heat Input = {{LME Gen CP Total Heat Input -
LME Gen CP April Heat Input) * Current LME Hourly Op
Record. HourLoad * Current LME Hourly Op Record.OpTime / {LME
Gen Total Load - LME Gen April Load)) + {{LME Gen LTFF Heat
Input Array for the location - LME Gen LTFF April Heat Input Array
for the location) * Current LME Hourly Op Record.HourLoad *
Current LME Hourly Op Record. OpTime / {LME Gen Total Load
Array for the location - LME Gen April Load Array for the location)),
and round the result to 1 decimal place.
else if LME Gen Total Optime is greater than 0,
Calculate LME Calc Heat Input = {{LME Gen CP Total Heat Input - LME
Gen CP April Heat Input) * Current LME Hourly Op Record. OpTime / {LME
Gen Total Optime - LME Gen April Optime)) + {{LME Gen LTFF Heat Input
Array for the location - LME Gen LTFF April Heat Input Array for the
location) * Current LME Hourly Op Record.OpTime / {LME Gen Total Optime
Array for the location - LME Gen LTFF April Op Time Array for the location)),
and round the result to 1 decimal place.
Otherwise,
if LME Gen Total Load is greater than 0,
If Current LME Hourly Op Record.HomLonA is equal to 0,
Set LME Calc Heat Input = 0
else
Calculate LME Calc Heat Input = {LME Gen CP Total Heat Input * Current
LME Hourly Op Record.HourLoad * Current LME Hourly Op Record. OpTime
/ LME Gen Total Load) + {LME Gen LTFF Heat Input Array for the location *
Current LME Hourly Op Record.HourLoad * Current LME Hourly Op
Record:OpTime / LME Gen Total Load Array for the location), and round the
result to 1 decimal place.
else if LME Gen Total Optime is greater than 0,
Calculate LME Calc Heat Input = {LME Gen CP Total Heat Input * Current LME
Hourly Op Record.OpTime / LME Gen Total Optime) + {LME Gen LTFF Heat Input
Array for the location * Current LME Hourly Op Record.OpTime / LME Gen LTFF
Total Op Time Array for the location), and round the result to 1 decimal place.
Environmental Protection Agency
Page 634 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
If LME Calc Heat Input is not null,
If LME Calc Heat Input is greater than 999,999.9
If LME Gen Parameters contains "S02M",
set LME Gen Total S02MArray for location to -1.
If LME Gen Parameters contains "NOXM",
set LME Gen Total NOXM Array for location to -1.
If LME Gen Parameters contains "C02M",
set LME Gen Total C02M Array for location to -1.
set LME Calc Heat Input to null, LME Gen Total Heat Input Array for location to -1, and return result
B.
else if LME Calc Heat Input is greater than or equal to 0,
LME Gen Heat Input Record.HourlD = Current LME Hourly Op RecordHom\D
LME Gen Heat Input Record.ParameterCode = "HIT"
LME Gen Heat Input Record. AdjustedHourlyValue = LME Calc Heat Input
If Current LME Hourly Op Record. IVTH H11 ndicator is equal to 1,
LME Gen Heat Input Record.MODCCode = "45"
If LME Gen Total Heat Input Array for location is greater than or equal to 0,
Add LME Calc Heat Input to LME Gen Total Heat Input Array for location.
If current date in the month of April,
Add LME Calc Heat Input to LME Gen April Heat Input Array for location.
Otherwise,
If LME Gen Parameters is not null, AND
(LME Gen Annual is equal to true OR the current date is in the months of May thru September),
If LME Gen Parameters contains "S02M",
set LME Gen Total S02M Array for location to -1.
If LME Gen Parameters contains "NOXM",
set LME Gen Total NOXM Array for location to -1.
If LME Gen Parameters contains "C02M",
set LME Gen Total C02M Array for location to -1.
set LME Gen Total Heat Input Array for location to -1.
Environmental Protection Agency
Page 635 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result Response Severity
A You did not report a single, active, valid default record for MHHI in your monitoring Critical Error Level 1
plan.
B The value calculated for [param] in the LME Hourly record exceeds the maximum Critical Error Level 1
value.
Usage:
1 Process/Category: LME Emissions Data Generation Hourly Emissions Data
Environmental Protection Agency
Page 636 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: LME-29
Check Name: Calculate S02 Mass for LME Unit
Related Former Checks:
Applicability:
Description:
Specifications:
LME Gen S02M Record = null
If LME Gen Parameters contains "S02M" and Current LME Hourly Op Record is not null,
If Current LME Hourly Op Fuel Code List is not null,
S02 Rate = 0
S02 Fuel = null
For each FuelCode in the Current LME Hourly Op /?6'cwy/. Fuel Code List
Locate all Monitor Default Records for the location and hour where ParameterCode is equal to "S02R",
DefaultPurposeCd = "LM", and FuelCode is equal to the current FuelCode.
If one and only one record is found, the DefaultValue is greater than 0, and DefaultUnitsOfMeasureCode is equal
to "LBMMBTU",
If SO2 Rate is less than the DefaultValue in the retrieved record,
set SO2 Rate to the DefaultValue.
set SO2 Fuel to the current FuelCode.
Otherwise,
set LME Gen Total S02M Array for location to -1, LME Gen Fuel Code to the current FuelCode,
and return result A.
If LME Calc Heat Input is not null and is greater than or equal to 0 AND SO2 Rate is greater than 0,
Calculate SO2 Mass = LME Calc Heat Input * SO2 Rate, and round the result to 1 decimal place.
If SO2 Mass is greater than 99,999.9
set LME Gen Total S02MArray for location to -1, and return result B.
Otherwise,
LME Gen S02MRecord.HourlD = Current LME Hourly Op RecordRom\D
LME Gen S02M Record. ParameterCode = "S02M"
LME Gen S02MRecord. AdjustedHourlyValue = S02 Mass
LME Gen S02MRecord.FuelCode = S02 Fuel
If LME Gen Total S02MArray for location is greater than or equal to 0,
Add SO2 Mass to LME Gen Total S02M Array for location.
Environmental Protection Agency
Page 637 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result Response Severity
A You did not report a single, active, valid [defparm] default record for FuelCode [fuel] in Critical Error Level 1
your monitoring plan.
B The value calculated for [param] in the LME Hourly record exceeds the maximum Critical Error Level 1
value.
Usage:
1 Process/Category: LME Emissions Data Generation Hourly Emissions Data
Environmental Protection Agency
Page 638 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
LME-30
Check Name:
Related Former Checks:
Calculate NOX Mass for LME Unit
Applicability:
Description:
Specifications:
LME Gen NOXM Record = null
If LME Gen Parameters contains "NOXM" and Current LME Hourly Op Record is not null and Current LME Hourly Op
Record.0\y\\mc is greater than 0,
If Current LME Hourly Op /?6'cw
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Otherwise,
LME Gen NOXM Record MourlD = Current LME Hourly Op RecordHowcYD
LME Gen NOXM Record. ParamctcrCodc = "NOXM"
LME Gen NOXM Record, kdi] ustcdHourly Value = NOXMass
LME Gen NOXM Record.¥uc\CoAc = NOX Fuel
LME Gen NOXM Record. Opcra t i ngCondi t io nCodc = Current LME Hourly Op Record. Opc rat i ngCo ndi t io nCode
If LME Gen Total NOXM Array for location is greater than or equal to 0,
Add NOX Mass to LME Gen Total NOXM Array for location.
If current date in the month of April,
Add NOX Mass to LME Gen April NOXM Array for location.
Results:
Result
A
Response
You did not report a single, active, valid [defparm] default record for FuelCode [fuel] in
your monitoring plan.
You did not report a single, active, valid [defparm] default record for FuelCode [fuel]
OperatingConditionCode [cond] in your monitoring plan.
The value calculated for [param] in the LME Hourly record exceeds the maximum
value.
Severity
Critical Error Level 1
B
Critical Error Level 1
C
Critical Error Level 1
Usage:
1 Process/Category: LME Emissions Data Generation Hourly Emissions Data
Environmental Protection Agency
Page 640 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: LME-31
Check Name: Calculate C02 Mass for LME Unit
Related Former Checks:
Applicability:
Description:
Specifications:
LME Gen C02M Record = null
If LME Gen Parameters contains "C02M" and Current LME Hourly Op Record is not null,
If Current LME Hourly Op Fuel Code List is not null,
C02 Rate = 0
C02 Fuel = null
For each FuelCode in the Current LME Hourly Op /?6'cwy/. Fuel Code List
Locate all Monitor Default Records for the location and hour where ParameterCode is equal to "C02R",
DefaultPurposeCd = "LM", and FuelCode is equal to the current FuelCode.
If one and only one record is found, the DefaultValue is greater than 0, and DefaultUnitsOfMeasureCode is equal
to "TNMMBTU",
If C02 Rate is less than the DefaultValue in the retrieved record,
set C02 Rate to the DefaultValue.
set C02 Fuel to the current FuelCode.
Otherwise,
set LME Gen Total C02M Array for location to -1, LME Gen Fuel Code to the current FuelCode,
and return result A.
If LME Calc Heat Input is not null and is greater than or equal to 0 AND CO2 Rate is greater than 0,
Calculate C02 Mass = LME Calc Heat Input * C02 Rate, and round the result to 1 decimal place.
If C02 Mass is greater than 99,999,999.9
set LME Gen Total C02M Array for location to -1, and return result B.
Otherwise,
LME Gen C()2M Record. HourID = Current LME Hourly Op Record.HourlD
LME Gen C()2M Record.?-Mm\c{cxCoAc = "C02M"
LME Gen C()2MRecord. Ad)ustedHourly Value = C02 Mass
LME Gen C02MRecordIuqXCo&q = C02 Fuel
If LME Gen Total C02MArray for location is greater than or equal to 0,
Add C02 Mass to LME Gen Total C02M Array for location.
Environmental Protection Agency
Page 641 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result Response Severity
A You did not report a single, active, valid [defparm] default record for FuelCode [fuel] in Critical Error Level 1
your monitoring plan.
B The value calculated for [param] in the LME Hourly record exceeds the maximum Critical Error Level 1
value.
Usage:
1 Process/Category: LME Emissions Data Generation Hourly Emissions Data
Environmental Protection Agency
Page 642 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: LME-32
Check Name: Calculate HIT Summary Values
Related Former Checks:
Applicability:
Description:
Specifications:
LME Summary Heat Input Record = null
If location is a common pipe,
tempHIT = LME Gen LTFF Heat Input Array for the location
tempAprilHIT = LME Gen LTFF April Heat Input Array for the location
else
tempHIT = If LME Gen Total Heat Input Array for the location
tempAprilHIT = LME Gen April Heat Input Array for the location
If tempHIT is greater than or equal to 0,
LME Summary Heat Input Record.MonLocld = current location ID
LME Summary Heat Input Record. RcportingPcriodld = current reporting period ID
I.ME Summary Heat Input Record. ParamctcrCodc = "HIT"
If LME Gen OS == true and LME Gen Annual == false and Quarter of Reporting Period is equal to 2,
LME Summary Heat Input /feca/v/. Current RcportingPeriodTotal = tempHIT - tempAprilHIT, rounded to 0 decimal places.
else
LME Summary Heat Input Current RcportingPeriodTotal = tempHIT, rounded to 0 decimal places.
If LME Gen OS == true,
If Quarter of Reporting Period is equal to 2,
LME Summary Heat Input /?6'ewY/.OzoncScasonToDatcTotal = tempHIT - tempAprilHIT, rounded to 0 decimal
places.
else if Quarter of Reporting Period is equal to 3,
LME Summary Heat Input /?6'ewY/.OzoncScasonToDatcTotal = tempHIT, rounded to 0 decimal places.
else if Quarter of Reporting Period is equal to 4 AND LME Year Start Quarter is less than 4,
Locate the Op Supp Data records for the location WHERE the reporting period is the third quarter of the Year of
the Reporting Period and OpTypeCode = "HIT".
If not found,
set LME Summary Heat Input /?6'cwY/.OzoneScasonToDateTotal to null, and return result A.
Otherwise,
LME Summary Heat Input /?6'ewY/.OzoncScasonToDatcTotal = OpValue in the retrived record.
if Quarter of Reporting Period is equal to 3 or 4 AND LME Year Start Quarter is less than 3,
Locate the Op Supp Data records for the location WHERE the reporting period is the second quarter of the Year
of the Reporting Period and OpTypeCode = "HITOS".
If not found,
set LME Summary Heat Input /?6'ewY/.OzoncScasonToDatcTotal to null, and return result A.
Otherwise,
Environmental Protection Agency
Page 643 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
add OpValue in the retrieved record to LME Summary Heat Input Ttecon/.OzoneSeasonToDateTotal.
If LME Gen Annual == true,
LME Summary Heat Input Record YearToDateTotal = LME Summary Heat Input Record. Currc litRcpo rt i ngPc riodTota 1.
rounded to 0 decimal places.
If the quarter of the current reporting period is greater than the LME Year Start Quarter,
For each reporting period in the year of the current reporting period and in a quarter that is on or after the LME
Year Start Quarter and is prior to the current reporting period.
Locate the Op Supp Data records for the location and reporting period WHERE the OpTypeCode =
"HIT".
If not found,
set LME Summary Heat Input Record. YcarToDatcTota 1 to null, and return result B.
Otherwise,
add OpValue in the retrieved record to LME Summary Heat Input Record. YearToDateTotal.
Results:
Result
A
B
Usage:
1
Response
The program could not determine ozone-season-to-date totals for [osparam], because
the Op Supp Data record for this parameter is missing for one or more previous
reporting periods. If you have submitted emissions data for prior quarters, you should
be able to retrieve these records by logging on to the EPA host.
The program could not determine year-to-date for [param], because the Op Supp Data
record for this parameter is missing for one or more previous reporting periods. If you
have submitted emissions data for prior quarters, you should be able to retrieve these
records by logging on to the EPA host.
Process/Category: LME Emissions Data Generation Summary Value Data
Severity
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 644 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
LME-33
Check Name:
Calculate OPTIME Summary Values
Related Former Checks:
Applicability:
Description:
Specifications:
LME Summary Op Time Record = null
If location is a unit AND LME Gen Total Op Time Array for the location is greater than or equal to 0,
LME Summary Op Time Record. MonLocId = current location ID
LME Summary Op Time Record. Rcpo rti ngPc riodld = current reporting period ID
LME Summary Op Time Record.ParameterCode = "OPTIME"
If LME Gen OS == true and LME Gen Annual == false and Quarter of Reporting Period is equal to 2,
LME Summary Op Time Ttecon/.CurrentReportingPeriodTotal = LME Gen Total Op Time Array for the location - LME
Gen April Op Time Array for the location.
LME Summary Op Time /?6'cwy/. Current Rcpo rtingPeriodTotal = LME Gen Total Op Time Array for the location.
If LME Gen OS == true,
If Quarter of Reporting Period is equal to 2,
LME Summary Op Time Record.O/o ne Seaso nTo DateTotal = LME Gen Total Op Time Array for the location -
LME Gen April Op Time Array for the location.
else if Quarter of Reporting Period is equal to 3,
LME Summary Op Time Record.O/o ne Seaso nT o DateTotal = LME Gen Total Op Time Array for the location.
else if Quarter of Reporting Period is equal to 4 AND LME Year Start Quarter is less than 4,
Locate the Op Supp Data records for the location WHERE the reporting period is the third quarter of the Year of
the Reporting Period and OpTypeCode = "OPTIME".
If not found,
set LME Summary Op Time /?6'ewY/.OzoncScasonToDatcTotal to null, and return result A.
Otherwise,
LME Summary Op Time Record. O zo ne Sea so nTo D ateTo ta 1 = OpValue in the retrived record.
if Quarter of Reporting Period is equal to 3 or 4 AND LME Year Start Quarter is less than 3,
Locate the Op Supp Data records for the location WHERE the reporting period is the second quarter of the current
year and OpTypeCode = "OSTIME".
If not found,
set LME Summary Op Time /?6'cw
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
If LME Gen Annual == true,
LME Summary Op 2Y»ie7?ecor
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: LME-34
Check Name: Calculate OPHOURS Summary Values
Related Former Checks:
Applicability:
Description:
Specifications:
LME Summary Op Hours Record = null
If location is a unit AND LME Gen Total Op Time Array for the location is greater than or equal to 0,
LME Summary Op Hours Record.MonLocId = current location ID
LME Summary Op Hours Record. Rcpo rt i ngPcriodId = current reporting period ID
LME Summary Op Hours ./iecon/.ParameterCode = "OPHOURS"
If LME Gen OS == true and LME Gen Annual == false and Quarter of Reporting Period is equal to 2,
LME Summary Op Hours Record. C urrc n t Rc po rt i ng Pc ri odTo t a 1 = LME Gen Total Op Hours Array for the location -
LME Gen April Op Hours Array for the location.
else
LME Summary Op Hours Record. C urrc n t Rc po rt i ng Pc ri odTo t a 1 = LME Gen Total Op Hours Array for the location.
If LME Gen OS == true,
If Quarter of Reporting Period is equal to 2,
LME Summary Op Hours Ttecorrf.OzoneSeasonToDateTotal = LME Gen Total Op Hours Array for the location
- LME Gen April Op Hours Array for the location.
else if Quarter of Reporting Period is equal to 3,
LME Summary Op Hours Ttecorrf.OzoneSeasonToDateTotal = LME Gen Total Op Hours Array for the location.
else if Quarter of Reporting Period is equal to 4 AND LME Year Start Quarter is less than 4,
Locate the Op Supp Data records for the location WHERE the reporting period is the third quarter of the Year of
the Reporting Period and OpTypeCode = "OPHOURS".
If not found,
set LME Summary Op Hours /?6'cmy/. O zo lie S c a s o nTo D a tc To ta 1 to null, and return result A.
Otherwise,
LME Summary Op Hours /?«:¦ wy/. O zo lie S c a s o nTo D a tc To t a 1 = OpValue in the retrived record.
if Quarter of Reporting Period is equal to 3 or 4 AND LME Year Start Quarter is less than 3,
Locate the Op Supp Data records for the location WHERE the reporting period is the second quarter of the current
year and OpTypeCode = "OSHOURS".
If not found,
set LME Summary Op Hours wy/. Ozo lie ScasonTo Da tcTo ta 1 to null, and return result A.
Otherwise,
add OpValue in the retrieved record to LME Summary Op Hours Ttecon/.OzoneSeasonToDateTotal.
If LME Gen Annual == true,
LME Summary Op Hours Record. Y ca rT o DatcTota 1 = LME Summary Op Hours /?6'cwy/. Current Rcpo rtingPcriodTotal.
If the quarter of the current reporting period is greater than the LME Year Start Quarter,
For each reporting period in the year of the current reporting period and in a quarter that is on or after the LME
Environmental Protection Agency
Page 647 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Year Start Quarter and is prior to the current reporting period.
Locate the Op Supp Data records for the location and reporting period WHERE the OpTypeCode =
"OPHOURS".
If not found,
set LME Summary Op Hours YcarToDatcTotal to null, and return result B.
Otherwise,
add OpValue in the retrieved record to LME Summary Op Hours Record. Yca rTo DatcTota 1.
Results:
Result
A
B
Response
The program could not determine ozone-season-to-date totals for [osparam], because
the Op Supp Data record for this parameter is missing for one or more previous
reporting periods. If you have submitted emissions data for prior quarters, you should
be able to retrieve these records by logging on to the EPA host.
The program could not determine year-to-date for [param], because the Op Supp Data
record for this parameter is missing for one or more previous reporting periods. If you
have submitted emissions data for prior quarters, you should be able to retrieve these
records by logging on to the EPA host.
Severity
Critical Error Level 1
Critical Error Level 1
Usage:
1
Process/Category: LME Emissions Data Generation Summary Value Data
Environmental Protection Agency
Page 648 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
LME-35
Check Name:
Calculate S02M Summary Values
Related Former Checks:
Applicability:
Description:
Specifications:
LME Summary S02M Record = null
If location is a unit, LME Gen Annual == true, AND LME Gen Total S02M Array for the location is greater than or equal to 0,
Locate a Monitor Method record for the unit where the ParameterCode is equal to "S02M", and the MethodCode is equal to
"LME", BeginDate is on or before the first day of the reporting period, and the EndDate is null or is on or after the last day of the
reporting period.
LME Summary S()2M Record. Mo nLoc Id = current location ID
LME Summary .SY/2 A/ Repo rt i ngPe riodId = current reporting period ID
LME Summary S02MRecord.FammsterCode = "S02M"
LME Summary S()2M Record. Currclit Rcpo rti ngPc riodTota 1 = LME Gen Total S02M Array for the location / 2000,
rounded to one decimal place.
LME Summary S02M Record.YearToDateTotal = LME Summary S'O^M./tecon/.CurrentReportingPeriodTotal.
If the quarter of the current reporting period is greater than the LME Year Start Quarter,
For each reporting period in the year of the current reporting period and in a quarter that is on or after the LME
Year Start Quarter and is prior to the current reporting period.
If found,
Locate the Op Supp Data records for the location and reporting period WHERE the OpTypeCode
S02M".
If not found,
set LME Summary S()2M Record. YcarToDatcTota 1 to null, and return result A.
Otherwise,
add OpValue in the retrieved record to LME Summary S()2M Record. Yca rTo DatcTota 1.
Results:
Result
A
Response
The program could not determine year-to-date for [param], because the Op Supp Data
record for this parameter is missing for one or more previous reporting periods. If you
have submitted emissions data for prior quarters, you should be able to retrieve these
records by logging on to the EPA host.
Severity
Critical Error Level 1
Usage:
1 Process/Category: LME Emissions Data Generation Summary Value Data
Environmental Protection Agency
Page 649 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
LME-36
Check Name:
Calculate C02M Summary Values
Related Former Checks:
Applicability:
Description:
Specifications:
LME Summary C02M Record = null
If location is a unit, LME Gen Annual == true, AND LME Gen Total C02M Array for the location is greater than or equal to 0,
Locate a Monitor Method record for the unit where the ParameterCode is equal to "C02M", and the MethodCode is equal to
"LME", BeginDate is on or before the first day of the reporting period, and the EndDate is null or is on or after the last day of the
reporting period.
LME Summary C02MRecord.MoviLocld = current location ID
LME Summary C02MTtecon/.ReportingPeriodld = current reporting period ID
LME Summary C02MTtecon/.ParameterCode = "C02M"
LME Summary C()2M Record. Currc nt Rcpo rt i ngPc riodTota 1 = LME Gen Total C02M Array for the location.
LME Summary C02MTtecon/.YearToDateTotal = LME Summary C02MTtecon/.CurrentReportingPeriodTotal.
If the quarter of the current reporting period is greater than the LME Year Start Quarter,
For each reporting period in the year of the current reporting period and in a quarter that is on or after the LME
Year Start Quarter and is prior to the current reporting period.
If found,
Locate the Op Supp Data records for the location and reporting period WHERE the OpTypeCode
C02M".
If not found,
set LME Summary C()2M Record. YcarToDatcTota 1 to null, and return result A.
Otherwise,
add OpValue in the retrieved record to LME Summary C()2 M Record. Y ca rTo D a tc To t a 1.
Results:
Result
A
Response
The program could not determine year-to-date for [param], because the Op Supp Data
record for this parameter is missing for one or more previous reporting periods. If you
have submitted emissions data for prior quarters, you should be able to retrieve these
records by logging on to the EPA host.
Severity
Critical Error Level 1
Usage:
1 Process/Category: LME Emissions Data Generation Summary Value Data
Environmental Protection Agency
Page 650 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
LME-37
Check Name:
Related Former Checks:
Calculate NOXM Summary Values
Applicability:
Description:
Specifications:
LME Summary NOXM Record = null
If location is a unit AND LME Gen Total NOXM Array for the location is greater than or equal to 0.
Locate a Monitor Method record for the unit where the ParameterCode is equal to "NOXM", and the MethodCode is equal to
"LME", BeginDate is on or before the first day of the reporting period, and the EndDate is null or is on or after the last day of the
reporting period.
If found,
LME Summary NOXM Record. MonLocId = current location ID
IME Summary NOXM Record. RcportingPcriodld = current reporting period ID
LME Summary NOXM Record. ParameterCode = "NOXM"
If LME Gen OS == true and LME Gen Annual == false and Quarter of Reporting Period is equal to 2,
LME Summary NOXM Record. C u rrc n t Rcpo rt i ng Pc ri odTo ta 1 = {LME Gen Total NOXM Array for the location -
LME Gen April NOXM Array for the location) / 2000, rounded to one decimal place.
LME Summary NOXM Record. C u rrc lit Rcpo rt i ng Pc ri odTo ta 1 = LME Gen Total NOXM Array for the location /
2000, rounded to one decimal place.
ff LME Gen OS == true,
If Quarter of Reporting Period is equal to 2,
LME Summary NOXM Record.OzoneSeasonToDateTotal= (LME Gen Total NOXM Array fox the
location - LME Gen April NOXM Array for the location) / 2000, rounded to one decimal place.
else if Quarter of Reporting Period is equal to 3,
LME Summary NOXM wy/. Ozo ne Seaso nTo Da teTo t a 1 = LME Gen Total NOXM Array for the
location / 2000, rounded to one decimal place.
else if Quarter of Reporting Period is equal to 4 AND LME Year Start Quarter is less than 4,
Locate the Op Supp Data records for the location WHERE the reporting period is the third quarter of the
Year of the Reporting Period and OpTypeCode = "NOXM".
If not found,
set LME Summary NOXM /?6'ewY/.OzoncScasonToDatcTotal to null, and return result A.
Otherwise,
LME Summary NOXM Record.O/o ne Seaso nTo DateTotal = OpValue in the retrived record.
if Quarter of Reporting Period is equal to 3 or 4 AND LME Year Start Quarter is less than 3,
Locate the Op Supp Data records for the location WHERE the reporting period is the second quarter of
the current year and OpTypeCode = "NOXMOS".
If not found,
set LME Summary NOXM /?6'ewY/.OzoncScasonToDatcTotal to null, and return result A.
Otherwise,
add OpValue in the retrieved record to LME Summary NOXM
else
Environmental Protection Agency
Page 651 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Record. Ozone SeasonT oDateT otal.
If LME Gen Annual == true,
LME Summary NOXM Ttecon/.YearToDateTotal = LME Summary NOXM
Record. CurrentReportingPeriodT otal.
If the quarter of the current reporting period is greater than the LME Year Start Quarter,
For each reporting period in the year of the current reporting period and in a quarter that is on or after the
LME Year Start Quarter and is prior to the current reporting period.
Locate the Op Supp Data records for the location and reporting period WHERE the OpTypeCode
= "NOXM".
If not found,
set LME Summary NOXM Record. YcarTo DatcTota 1 to null, and return result B.
Otherwise,
add OpValue in the retrieved record to LME Summary NOXM
Record. Y earT oD ateT otal.
Results:
Result
A
B
Response
The program could not determine ozone-season-to-date totals for [osparam], because
the Op Supp Data record for this parameter is missing for one or more previous
reporting periods. If you have submitted emissions data for prior quarters, you should
be able to retrieve these records by logging on to the EPA host.
The program could not determine year-to-date for [param], because the Op Supp Data
record for this parameter is missing for one or more previous reporting periods. If you
have submitted emissions data for prior quarters, you should be able to retrieve these
records by logging on to the EPA host.
Severity
Critical Error Level 1
Critical Error Level 1
Usage:
1
Process/Category: LME Emissions Data Generation Summary Value Data
Environmental Protection Agency
Page 652 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: LME-38
Check Name: Calculate NOXR Summary Values
Related Former Checks:
Applicability:
Description:
Specifications:
LME Summary NOXR Record = null
If LME Summary Heat Input Record and LME Summary NOXM Record are both not null,
Locate a Program record for the unit where the ProgramCode is equal to "ARP", the Class is not equal to "NA",
UnitMonitorCertBeginDate is on or before the first day of the reporting period, and the EndDate is null or is on or after the last day
of the reporting period.
If found,
LME Summary NOXR Record. MonLocId = current location ID
LME Summary NOXR Record. Rcpo rti ngPc riodld = current reporting period ID
LME Summary NOXR Ttecon/.ParameterCode = "NOXR"
If LME Summary NOXM Record. RcportingPcriodTotal == 0
LME Summary NOXR Record. Currc nt Rcpo rt i ngPcriodTo ta 1 = 0
else
LME Summary NOXR Record. C u rrc n t R c po rt i ng P c ri o dTo ta 1 = LME Gen Total NOXM Array for the location /
LME Summary Heat Input /?6'ewY/.RcportingPcriodTotal. rounded to 3 decimal places.
If the quarter of the current reporting period is greater than the LME Year Start Quarter,
If LME Summary Heat Input Record. YearToDateTotal is not null,
NOxTotal = LME Gen Total NOXM Array for the location.
For each reporting period in the year of the current reporting period and in a quarter that is on or after the
LME Year Start Quarter and is prior to the current reporting period.
Locate the Op Supp Data records for the location and reporting period WHERE the OpTypeCode
= "NOXR".
If not found,
set LME Summary NOXR Record. YcarToDatcTotal to null, and return result A.
Otherwise,
NOXRValue = OpValue.
Locate the Op Supp Data records for the location and reporting period WHERE the
OpTypeCode = "HIT".
If not found,
set LME Summary NOXR Record. Y carToDatcT otal to null, and return result B.
Otherwise,
Add OpValue * NOXRValue (rounded to 1 decimal) to NOxTotal.
ff NOxTotal == 0,
LME Summary NOXR Record. YearToDateTotal = 0.
Environmental Protection Agency
Page 653 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
else
LME Summary NOXR Record. Y ca rT o DatcT ota 1 = NOxTotal / LME Summary Heat Input
Record earToDateTotal. rounded to 3 decimal places.
else
LME Summary NOXR Ttecon/.YearToDateTotal = LME Summary NOXR Ttecon/.CurrentReportingPeriodTotal.
Results:
Result
A
B
Response
The program could not determine year-to-date for [param], because the Op Supp Data
record for this parameter is missing for one or more previous reporting periods. If you
have submitted emissions data for prior quarters, you should be able to retrieve these
records by logging on to the EPA host.
The program could not determine year-to-date for [param], because the Op Supp Data
record for HIT is missing for one or more previous reporting periods. If you have
submitted emissions data for prior quarters, you should be able to retrieve these records
by logging on to the EPA host.
Severity
Critical Error Level 1
Critical Error Level 1
Usage:
1
Process/Category: LME Emissions Data Generation Summary Value Data
Environmental Protection Agency
Page 654 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
LME-40
Check Name:
Check LME MHHI Indicator
Related Former Checks:
Applicability:
Description:
Specifications:
If Current LME Hourly Op Record is not null,
If MHHIIndicator is equal to 1,
If LME Gen HI Substitute Data is not equal to "MHHI",
set Generate LME to false, and return result A.
Results:
Result
A
Response
You reported a MHHIIndicator, but you did not report an active LTFF heat input
method with a SubstituteDataCode of "MHHI".
Severity
Critical Error Level 1
Usage:
1 Process/Category: LME Emissions Data Generation Hourly Emissions Data
Environmental Protection Agency
Page 655 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
LME-44
Check Name:
Check Fuel Codes against LTFF Records
Related Former Checks:
Applicability:
Description:
Specifications:
If Current LME Hourly Op Record is not null and LME Gen HI Method = "LTFF",
If MHHIIndicator is not equal to 1 and FuelCodeList is not null,
Locate all Unit Stack Configuration Records where the unit location is the location in the Current LME Hourly Op
Record, the StackID begins with "CP", the BeginDate and BeginHour is on or before the Date and Hour in the Current
LME Hourly Op Record, and the EndDate is null or the EndDate and EndHour is on or after the Date and Hour in the
Current LME Hourly Op Record.
For each FuelCode in FuelCodeList,
Locate a LTFF Record for the configuration and reporting period where the location is the location in the Current
LME Hourly Op Record or is any of the common pipes in the retrieved Unit Stack Configuration Records, and
the FuelCode of the associated fuel flow system is equal to the FuelCode in the FuelCodeList that is being
evaluated.
If not found for any FuelCode,
set Generate LME to false, and return result A.
Results:
Result
A
Response
You did not report a Long Term Fuel Flow record for a fuel flow system for one or
more fuels in the FuelCodeList in the LME Hourly record. If you burn a fuel that is not
measured by a fuel flow meter, you must use maximum hourly heat input for the hour.
Severity
Critical Error Level 1
Usage:
1 Process/Category: LME Emissions Data Generation Hourly Emissions Data
Environmental Protection Agency
Page 656 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
LME-45
Check Name:
Duplicate LTFF Record
Related Former Checks:
Applicability:
Description:
Specifications:
For the LTFF record:
Locate another LTFF record for the location with same ReportingPeriod, MonitoringSystemID, and FuelFlowPeriodCode as the
current record.
If found,
return result A.
Results:
Result
A
Response
Another [recordtype] record already exists with the same [fieldnames].
Severity
Fatal
Usage:
1 Process/Category: LME Emissions Data Generation LTFF Heat Input Data
Environmental Protection Agency
Page 657 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
LME-18
Check Name:
Check LME Begin Hour
Related Former Checks:
Applicability:
Description:
Specifications:
For the LME Hourly Op record:
If BeginHour is null or is not between 0 and 23 (inclusive),
return result A.
Results:
Result
A
Response
The Hour is missing or invalid.
Severity
Fatal
Usage:
1 Process/Category: Emissions Data Entry Screen Evaluation Hourly Op Data Evaluation
Environmental Protection Agency
Page 658 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
LME-19
Check Name:
Check LME Begin Date
Related Former Checks:
Applicability:
Description:
Specifications:
For the LME Hourly Op record:
If BeginDate is null or is not within the reporting period,
return result A.
Results:
Result
A
Response
The Date is missing or not within the reporting period.
Severity
Fatal
Usage:
1 Process/Category: Emissions Data Entry Screen Evaluation Hourly Op Data Evaluation
Environmental Protection Agency
Page 659 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
LME-20
Check Name:
Duplicate LME Hourly Op Record
Related Former Checks:
Applicability:
Description:
Specifications:
For the LME Hourly Op record:
Locate another Hourly Op record for the location with same BeginDate and BeginHour.
If found,
return result A.
Results:
Result
A
Response
Another [recordtype] record already exists with the same [fieldnames].
Severity
Fatal
Usage:
1 Process/Category: Emissions Data Entry Screen Evaluation Hourly Op Data Evaluation
Environmental Protection Agency
Page 660 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
LME-23
Check Name:
Check LME Data Entry Screen Op Time
Related Former Checks:
Applicability:
Description:
Specifications:
For the LME Hourly Op record:
If OpTime is null, or is not between 0 and 1 inclusive,
return result A.
Results:
Result
A
Response
The [fieldname] reported in the LME Hourly record is missing or invalid.
Severity
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Entry Screen Evaluation Hourly Op Data Evaluation
Environmental Protection Agency
Page 661 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: LME-25
Check Name: Check LME Data Entry Screen Load Value
Related Former Checks:
Applicability:
Description:
Specifications:
For the LME Hourly Op record:
If LoadValue is null,
If OperatingTime is greater than 0,
return result A.
else if LoadValue is less than 0,
return result A.
else
If OperatingTime is equal to 0,
return result B.
Results:
Result Response Severity
A The [fieldname] reported in the LME Hourly record is missing or invalid. Critical Error Level 1
B You reported a LoadValue in the LME Hourly record. This field should be blank for a Non-Critical Error
non-operating hour.
Usage:
1 Process/Category: Emissions Data Entry Screen Evaluation Hourly Op Data Evaluation
Environmental Protection Agency
Page 662 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: LME-43
Check Name: Check LTFF Fuel Flow Period Code
Related Former Checks:
Applicability:
Description:
Specifications:
For the LTFF record:
If the Quarter of the reporting period is not equal to 2,
If the FuelFlowPeriodCode is not null,
return result A.
Results:
Result Response Severity
A You reported a FuelFlowPeriodCode in the LTFF record for [key], but this value is only Critical Error Level 1
appropriate during the second quarter.
Usage:
1 Process/Category: Emissions Data Entry Screen Evaluation LTFF Data Evaluation
Environmental Protection Agency
Page 663 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Category:
MATS Calculated Hourly Value Checks
Environmental Protection Agency
Page 664 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
Check Name:
Related Former Checks:
Applicability:
Description:
Specifications:
CalculationConversionFactor = 6.24 x 10 A -11
CurrentDh v Parameter = MatsHgDhvParameter
CurrentDhvRecordValid = MatsHgDhvValid
MatsDh v Record = MatsHgDh v Record
MatsMhvCalculatedValue = MatsMhvCalculatedHgcValue
MatsMh v Record = MatsHgcMh v Record
MatsMoistureEquationList = {A-3}
MatsDhvMeasuredModcListto {36, 39}
MatsDhvUnavailableModcListto {38}
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS Hg RE Calculation Verification
MATSCHV-1
Initialize HGRE Calculated Hourly Data
Environmental Protection Agency
Page 665 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
Check Name:
Related Former Checks:
Applicability:
Description:
Specifications:
CalculationConversionFactor = 9.43 x 10 A -8
CurrentDh v Parameter = MatsHclDh vParameter
CurrentDhvRecordValid = MatsHclDhvValid
MatsDh v Record = MatsHclDh v Record
MatsMhvCalculatedValue = MatsMhvCalculatedHclcValue
MatsMh v Record = MatsHctcMh vRecord
MatsMoistureEquationList = {HC-3 }
MatsDhvMeasuredModcListto {36, 39}
MatsDhvUnavailableModcListto {38}
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS HC1 RE Calculation Verification
MATSCHV-2
Initialize HCLRE Calculated Hourly Data
Environmental Protection Agency
Page 666 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
Check Name:
Related Former Checks:
Applicability:
Description:
Specifications:
CalculationConversionFactor = 5.18 x 10 A -8
CurrentDh v Parameter = MatsHfDh vParameter
CurrentDhvRecordValid = MatsHfDhvValid
MatsDh v Record = MatsHfDh v Record
MatsMhvCalculatedValue = MatsMhvCalculatedHfcValue
MatsMh v Record = MatsHfcMh v Record
MatsMoistureEquationList = {HF-3 }
MatsDhvMeasuredModcListto {36, 39}
MatsDhvUnavailableModcListto {38}
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS HF RE Calculation Verification
MATSCHV-3
Initialize HFRE Calculated Hourly Data
Environmental Protection Agency
Page 667 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
Check Name:
Related Former Checks:
Applicability:
Description:
Specifications:
CalculationConversionFactor = 1.66 x 10 A -7
CurrentDh v Parameter = MatsSo21)h v Parameter
CurrentDhvRecordValid = MatsSo2DhvValid
MatsDh v Record = MatsSo2 Dh v Record
MatsMoistureEquationList = { S-3 }
MatsDhvMeasuredModcListto {36, 39}
MatsDhvUnavailableModcListto {38}
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS S02 RE Calculation Verification
MATSCHV-4
Initialize S02RE Calculated Hourly Data
Environmental Protection Agency
Page 668 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSCHV-5
Check Name:
Initialize HGRH Calculated Hourly Data
Related Former Checks:
Applicability:
Description:
Specifications:
CalculationConversionFactor = 6.24 x 10 A -11
CurrentDh v Parameter = MatsHgDhvParameter
CurrentDhvRecordValid = MatsHgDhvValid
MatsDh v Record = MatsHgDh v Record
MatsMhvCalculatedValue = MatsMhvCalculatedHgcValue
MatsMh v Record = MatsHgcMh v Record
MatsMoistureEquationList = {19-3, 19-3D, 19-4, 19-5, 19-8, 19-9}
MatsDhvMeasuredModcList to {36, 37}
MatsDhvUnavailableModcListto {38}
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS Hg RH Calculation Verification
Environmental Protection Agency
Page 669 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSCHV-6
Check Name:
Initialize HCLRH Calculated Hourly Data
Related Former Checks:
Applicability:
Description:
Specifications:
CalculationConversionFactor = 9.43 x 10 A -8
CurrentDh v Parameter = MatsHclDh vParameter
CurrentDhvRecordValid = MatsHclDhvValid
MatsDh v Record = MatsHclDh v Record
MatsMhvCalculatedValue = MatsMhvCalculatedHclcValue
MatsMh v Record = MatsHctcMh vRecord
MatsMoistureEquationList = {19-3, 19-3D, 19-4, 19-5, 19-8, 19-9}
MatsDhvMeasuredModcList to {36, 37}
MatsDhvUnavailableModcListto {38}
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS HC1RH Calculation Verification
Environmental Protection Agency
Page 670 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSCHV-7
Check Name:
Initialize HFRH Calculated Hourly Data
Related Former Checks:
Applicability:
Description:
Specifications:
CalculationConversionFactor = 5.18 x 10 A -8
CurrentDh v Parameter = MatsHfDh vParameter
CurrentDhvRecordValid = MatsHfDhvValid
MatsDh v Record = MatsHfDh v Record
MatsMhvCalculatedValue = MatsMhvCalculatedHfcValue
MatsMh v Record = MatsHfMh v Record
MatsMoistureEquationList = {19-3, 19-3D, 19-4, 19-5, 19-8, 19-9}
MatsDhvMeasuredModcList to {36, 37}
MatsDhvUnavailableModcListto {38}
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS HF RH Calculation Verification
Environmental Protection Agency
Page 671 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSCHV-8
Check Name:
Initialize S02RH Calculated Hourly Data
Related Former Checks:
Applicability:
Description:
Specifications:
CalculationConversionFactor = 1.66 x 10 A -7
CurrentDh v Parameter = MatsSo21)h v Parameter
CurrentDhvRecordValid = MatsSo2DhvValid
MatsDh v Record = MatsSo2 Dh v Record
MatsMoistureEquationList = {19-3, 19-3D, 19-4, 19-5, 19-8, 19-9}
MatsDhvMeasuredModcList to {36, 37}
MatsDhvUnavailableModcListto {38}
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS S02 RH Calculation Verification
Environmental Protection Agency
Page 672 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSCHV-9
Check Name: Determine the Calculation Concentration for a MATS Parameter
Related Former Checks:
Applicability:
Description:
Specifications:
CalculationConcentration = null
CalculationConcentrationSubstituted = false
If CurrentDhvRecordValid AND (MatsDhvRecord.ModcCode in MatsDhvMeasuredModcList)
If {MatsMhvCalculatedValue is not null)
CalculationConcentration = MatsMhvCalculatedValue (convert from Scientific Notation)
If (MatsMhvRecordMatsMhvRecord is not null) AND (MatsMhvRecord.ModcCode is equal to "34" or "35")
CalculationConcentrationSubstituted = true
Results:
Result Response Severity
Usage:
1
Process/Category:
Emissions Data Evaluation Report —
— MATS
HC1 RE Calculation Verification
2
Process/Category:
Emissions Data Evaluation Report —
— MATS
HC1RH Calculation Verification
3
Process/Category:
Emissions Data Evaluation Report —
— MATS
HF RE Calculation Verification
4
Process/Category:
Emissions Data Evaluation Report —
— MATS
HF RH Calculation Verification
5
Process/Category:
Emissions Data Evaluation Report —
— MATS
Hg RE Calculation Verification
6
Process/Category:
Emissions Data Evaluation Report —
— MATS
Hg RH Calculation Verification
Environmental Protection Agency
Page 673 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSCHV-10
Check Name: Determine the Calculation Concentration for S02
Related Former Checks:
Applicability:
Description:
Specifications:
CalculationConcentration = null
CalculationConcentrationSubstituted = false
If CurrentDhvRecordValid AND (MatsDhvRecord.ModcCode in MatsDhvMeasuredModcList)
CalculationConcentration = CurrentSo2MonitorHourlyRecord.UnadjustedHourlyValue
If (CurrentSo2MonitorHourlyRecord.ModcCode in set {05, 06, 07, 08, 09, 10, 12, 13, 15, 18, 23, 55})
CalculationConcentrationSubstituted = true
Results:
Result Response
Usage:
1 Process/Category:
2 Process/Category:
Severity
Emissions Data Evaluation Report MATS S02 RE Calculation Verification
Emissions Data Evaluation Report MATS S02 RH Calculation Verification
Environmental Protection Agency
Page 674 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSCHV-11
Check Name:
Determine the Calculation Flow
Related Former Checks:
Applicability:
Description:
Specifications:
CalculationFlow = null
CalculationFlowSubstituted = false
If CurrentDhvRecordValid AND (MatsDhvRecord.ModcCode in MatsDhvMeasuredModcList)
If (CurrentStackFlowHourlyRecord is NOT null)
CalculationFlow = CurrentStackFlowHourlyRecord.UnadjustedHourlyYalue
If (CurrentStackFlowHourlyRecord.ModcCode not in set {01, 02, 03, 04, 20, 53, 54})
CalculationFlowSubstituted = true
Else
CalculationFlow = null
CalculationFlowSubstituted = false
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS HC1 RE Calculation Verification
2 Process/Category: Emissions Data Evaluation Report MATS HF RE Calculation Verification
3
Process/Category: Emissions Data Evaluation Report MATS Hg RE Calculation Verification
4 Process/Category: Emissions Data Evaluation Report MATS S02 RE Calculation Verification
Environmental Protection Agency
Page 675 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSCHV-12
Check Name: Determine the Calculation Diluent Value
Related Former Checks:
Applicability:
Description:
Specifications:
CalculationDiluent = null
CalculationDiluentSubstituted = false
If CurrentDhvRecordValid AND (MatsDhvRecord.ModcCode in MatsDhvMeasuredModcList)
If (MatsDhvRecord.EquationCode in set {19-3D, 19-5D} OR MatsDhvRecord.ModcCode == 37)
If (MatsDhvRecord.EquationCodc inset {19-1, 19-2, 19-3, 19-3D, 19-4, 19-5, 19-5D})
02MonitorDefaultMatches = count of MonitorDefaultRecordsByHourLocation where:
1) ParameterCode = "02X"
2) DefaultPurposeCode = "DC"
3) FuelCode = "NFS"
If (02MonitorDefaultMatches > 1)
return result A
Else if (02MonitorDefaultMatches == 0)
return result B
Else
02MonitorDefaultRecord = the single matched record
If (02MonitorDefaultRecord.DefmltVahie is NULL OR 02MonitorDefaultRecordDQfaultValuQ <= 0)
return result C
Else
CalculationDiluent = 02MonitorDefaultRecord.T>Qfau[tVahiQ
Else if (MatsDhvRecord.EquationCode in set {19-6, 19-7, 19-8, 19-9})
Co2MonitorDefaultMatches = count of MonitorDefaultRecordsByHourLocation where:
1) ParameterCode = "C02N"
2) DefaultPurposeCode = "DC"
3) FuelCode = "NFS"
If (Co2MonitorDefaultMatches > 1)
return result D
Else if (Co2MonitorDefaultMatches == 0)
return result E
Else
Co2MonitorDefaultRecord = the single matched record
If (Co2MonitorDefaultRecord.DefmltVahie is NULL OR Co2MonitorDefaultRecordDQfaultVdluQ <= 0)
return result F
Else
CalculationDiluent = Co2MonitorDefaultRecord .DefaultValue
Environmental Protection Agency
Page 676 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Else
If (MatsDh vRecord. Equatio nCodc in set { 19-1, 19-5} AND 02DryNeededForMats == true)
CalculationDiluent = 02DryCalculatedAdjustedValue
If (()2 Dry Mode not in set {01, 02, 03, 04, 17, 20, 53, 54})
CalculationDiluentSubstituted = true
Else if (MatsDh vReeord. Equat io nCodc in set {19-2, 19-3, 19-4} AND ()2 WetNeededFor Mats == true)
CalculationDiluent = 02WetCalculatedAdjustedValue
If (02WetModc not in set {01, 02, 03, 04, 17, 20, 53, 54})
CalculationDiluentSubstituted = true
Else if (MatsDhvReeord.EqmUonCodc in set { 19-6, 19-7, 19-8, 19-9} AND Co2DUuentNeededForMats== true)
CalculationDiluent = Co2cMhvCalculatedAdjustedValue
If (Co2cMhvModc not in set {01, 02, 03, 04, 17, 20, 21, 53, 54})
CalculationDiluentSubstituted = true
Results:
Result Response
A You reported more than one diluent cap default record for 02X in your monitoring plan
that was active during current hour.
B You did not report a default record for 02X in your monitoring plan that was active
during current hour.
C The DefaultValue reported in the active Default record for 02X in your monitoring
plan is invalid. The value must be greater than 0.
D You reported more than one diluent cap default record for C02N in your monitoring
plan that was active during the current hour.
E You did not report an active C02N diluent cap default record in your monitoring plan
for the hour.
F The DefaultValue reported in the active Default record for C02N in your monitoring
plan is invalid. The value must be greater than 0.
Usage:
1
Process/Category:
Emissions Data Evaluation Report —
— MATS HC1RH Calculation Verification
2
Process/Category:
Emissions Data Evaluation Report —
— MATS HF RH Calculation Verification
3
Process/Category:
Emissions Data Evaluation Report —
— MATS Hg RH Calculation Verification
4
Process/Category:
Emissions Data Evaluation Report —
— MATS S02 RH Calculation Verification
Seventy
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 677 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSCHV-13
Check Name:
Determine the Calculation Moisture
Related Former Checks:
Applicability:
Description:
Specifications:
CalculationMoisture = null
CalculationMoistureSubstituted = false
If CurrentDhvRecordValid AND (MatsDhvRecord.ModcCode in MatsDhvMeasuredModcList)
If (MatsDhvRecord.EquationCode in MatsMoistureEquationList)
Else if (H2oMethodCode in set {MMS, MTB}) AND H2oMonitorHourlyChecksNeeded AND
(H2oMhvCalculatedAdjustedValue is not null)
CalculationMoisture = H2oMhvCalculatedAdjustedValue
If (H2oMhvMode not in set {01, 02, 03, 04, 06, 07, 08, 09, 10, 12, 21, 53, 54, 55})
CalculationMoistureSubstituted = true
Else if (H2oMethodCode is equal to "MDF") AND H2oDerivedHourlyChecksNeeded AND
(H2oDhvCalculatedAdjustedValue is not null)
CalculationMoisture = H2oDhvCalculatedAdjustedValue
If (H2oDhvMode not in set {01, 02, 03, 04, 05, 06, 07, 08, 09, 10, 12, 21, 53, 54, 55})
CalculationMoistureSubstituted = true
Else if (H2oMethodCode is equal to "MDF") AND (H2oDerivedHourlyChecksNeeded is false) AND (H2oDefaultValue
is not null)
CalculationMoisture = H2oDefau1tValue
If (H2oMethodCode is equal to "MWD") AND H2oDerivedHourlyChecksNeeded AND
(H2oDhvCalculatedAdjustedValue is not null)
CalculationMoisture = H2oDhvCalculatedAdjustedValue
If (H2oDhvModc not in set {01, 02, 03, 04, 05, 06, 07, 08, 09, 10, 12, 21, 53, 54, 55})
CalculationMoistureSubstituted = true
Results:
Result
Response
Severity
Environmental Protection Agency
Page 678 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Usage:
1
Process/Category:
Emissions Data Evaluation Report —
— MATS HC1 RE Calculation Verification
2
Process/Category:
Emissions Data Evaluation Report —
— MATS HC1RH Calculation Verification
3
Process/Category:
Emissions Data Evaluation Report —
— MATS HF RE Calculation Verification
4
Process/Category:
Emissions Data Evaluation Report —
— MATS HF RH Calculation Verification
5
Process/Category:
Emissions Data Evaluation Report —
— MATS Hg RE Calculation Verification
6
Process/Category:
Emissions Data Evaluation Report —
— MATS Hg RH Calculation Verification
7
Process/Category:
Emissions Data Evaluation Report —
— MATS S02 RE Calculation Verification
8
Process/Category:
Emissions Data Evaluation Report —
— MATS S02 RH Calculation Verification
Environmental Protection Agency
Page 679 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSCHV-14
Check Name:
Check MODC and determine the MATS Formula Calculated Unadjusted Value
Related Former Checks:
Applicability:
Description:
Specifications:
CalculatedUnadjustedValue = null
If CurrentDhvRecordValid
If (Mats I) h v Record. Mode Code in MatsDhvMeasuredModcList)
If (MatsDh vRecord. EquationCodc is NOT null)
If (MatsDh vRecord. Equat io nCodc is in MatsMoistureEquationList)
If CalculationConcentrationSubstituted OR CalculationFlowSubstituted OR
CalculationMoistureSubstituted
return result A
Else if (CalculationConcentration is null) OR (CalculationFlow is null) OR (CalculationMoisture is
null)
return result B
Else
CalculatedUnadjustedValue = CalculationConversionFactor * CalculationConcentration *
CalculationFlow * (1 - CalculationMoisture))
Else
If CalculationConcentrationSubstituted OR CalculationFlowSubstituted
return result C
Else if (CalculationConcentration is null) OR (CalculationFlow is null)
return result D
Else
CalculatedUnadjustedValue = CalculationConversionFactor * CalculationConcentration *
Calcu lationFlow
Else
return result E
Else // Unavailable MODC
If (MatsDh vRecord. Equat io nCodc is NOT null)
return result E
Environmental Protection Agency
Page 680 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
A
B
C
D
Response
You reported an incorrect MODCCode in the MATS Derived Hourly Value record for
[param], as you reported substitute data for one or more essential auxiliary parameters.
You reported a Formulaldentifier in the MATS Derived Hourly Value record for
[param], but you did not report a value for all the essential parameters needed to
perform the calculation.
You reported an incorrect MODCCode in the MATS Derived Hourly Value record for
[param], as you reported substitute data for one or more essential auxiliary parameters.
You reported a Formulaldentifier in the MATS Derived Hourly Value record for
[param], but you did not report a value for all the essential parameters needed to
perform the calculation.
You reported an incorrect MODCCode in the MATS Derived Hourly Value record for
[param], as you reported measured data for essential auxiliary parameters.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS HC1 RE Calculation Verification
2 Process/Category: Emissions Data Evaluation Report MATS HF RE Calculation Verification
3 Process/Category: Emissions Data Evaluation Report MATS Hg RE Calculation Verification
4 Process/Category: Emissions Data Evaluation Report MATS S02 RE Calculation Verification
Environmental Protection Agency
Page 681 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSCHV-15
Check Name:
Related Former Checks:
Check MODC and determine the Formula 19 Calculated Unadjusted Value
Applicability:
Description:
Specifications:
CalculatedUnadjustedValue = null
If CurrentDhvRecordValid
If (MatsDh v Record. Mode Code in MatsDhvMeasuredModcList)
If (MatsDh vRecord. EquationCodc is NOT null)
Case (MatsDh vRecord. E q ua t i o n C o dc)
"19-1" :
If CalculationConcentrationSubstituted OR CalculationDiluentSubstkuted
return result A
Else if (CalculationDiluent is null) OR (CalculationConcentration is null) OR
(VatidFdFactor Exists is false)
return result C
Else if (CalculationDiluent is equal to 20.9)
return result D
CalculatedUnadjustedValue = CalculationConversionFactor *
CalculationConcentration * CurrentHourlyOpRecord.FdFactor * [20.9 / (20.9 -
CalculationDiluent)]
"19-2":
If CalculationConcentrationSubstituted OR CalculationDiluentSubstkuted
return result A
MoistureFraction = null
BwaDefaultRecordCount = count MonitorDefaultRecordsByHourLocation where
ParameterCd = 'BWA'
If (BwaDefaultRecordCount is equal to 0)
MoistureFraction = 0.027
Else If (BwaDefaultRecordCount is equal to 1) AND
(MonitorDefaultRecordsByHourLocation record's DefaultValue is greater than 0 AND
is less than 1)
MoistureFraction = MonitorDefaultRecordsByHourLocation record's
DefaultValue
Else
return result F
If (CalculationDiluent is null) OR (CalculationConcentration is null) OR
(ValidF\ v Factor Exists is false) OR {MoistureFraction is null)
return result C
Else
Else
Environmental Protection Agency
Page 682 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Else if (CalculationDiluent is equal to 20.9 * (1 - MoistureFraction))
return result D
Else
CalculatedUnadjustedValue = CalculationConversionF'actor *
CalculationConcentration * CurrentHourlyOpRecord .FwFactor * [20.9 / (20.9
*(1 - MoistureFraction) - CalculationDiluent)]
"19-3":
If CalculationConcentrationSubstituted OR CalculationDiluentSubstituted OR
CalculationMoistureSubstituted
return result A
Else if (CalculationDiluent is null) OR {CalculationConcentration is null) OR
{ValidFdFactorExists is false) OR (CalculationMoisture is null)
return result C
Else if (CalculationDiluent is equal to 20.9 * (100 - CalculationMoisture) / 100)
return result D
Else
h2oFactor = (100 - CalculationMoisture) / 100.0
denom = ((20.9 * h2oFactor) - CalculationDiluent)
CalculatedUnadjustedValue = CalculationConversionFactor *
CalculationConcentration * CurrentHourlyOpRecord.FdFactor * (20.9 Idenom)
"19-3D":
If CalculationConcentrationSubstituted OR CalculationDiluentSubstituted OR
CalculationMoistureSubstituted
return result A
Else if (CalculationDiluent is null) OR (CalculationConcentration is null) OR
{ValidFdFactorExists is false) OR (CalculationMoisture is null)
return result C
Else if (CalculationDiluent is equal to 20.9)
return result D
Else
h2oFactor = (100 - CalculationMoisture) / 100.0
denom = (20.9 * h2oFactor) - {CalculationDiluent * h2oFactor)
CalculatedUnadjustedValue = CalculationConversionFactor *
CalculationConcentration * CurrentHourlyOpRecord.FdFactor *(20.9 / denom)
"19-4":
If CalculationConcentrationSubstituted OR CalculationDiluentSubstituted OR
CalculationMoistureSubstituted
return result A
Else if (CalculationDiluent is null) OR (CalculationConcentration is null) OR
{ValidFdFactor Exists is false) OR {CalculationMoisture is null)
return result C
Environmental Protection Agency
Page 683 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Else if (CalculationDiluent is equal to 20.9) OR (CalculationMoisture is equal to 100)
return result D
Else
CalculatedUnadjustedValue = CalculationConversionFactor *
(CalculationConcentration * CurrentHourlyOpRecord.FdFactor / ((100 -
CalculationMoisture) / 100.0)) * (20.9 / (20.9 - CalculationDiluent))
"19-5":
If CalculationConcentrationSubstituted OR CalculationDiluentSubstituted OR
CalculationMoistureSubstituted
return result A
Else if (CalculationDiluent is null) OR (CalculationConcentration is null) OR
{ValidFdFactorExists is false) OR (CalculationMoisture is null)
return result C
Else if (CalculationDiluent is equal to 20.9) OR (CalculationMoisture is equal to 100)
return result D
Else
h2oFactor = (100 - CalculationMoisture) / 100.0
denom = 20.9 - (CalculationDiluent / h2oFactor)
CalculatedUnadjustedValue = CalculationConversionFactor *
CalculationConcentration * CurrentHourlyOpRecord.¥dFactor * 20.9 / denom
"19-5D":
If CalculationConcentrationSubstituted OR CalculationDiluentSubstituted
return result A
Else if (CalculationDiluent is null) OR (CalculationConcentration is null) OR
{ValidFdFactor Exists is false)
return result C
Else if (CalculationDiluent is equal to 20.9)
return result D
Else
CalculatedUnadjustedValue = CalculationConversionFactor *
CalculationConcentration * CurrentHourlyOpRecord.FdFactor * (20.9/ (20.9 -
CalculationDiluent))
"19-6" or "19-7":
If CalculationConcentrationSubstituted OR CalculationDiluentSubstituted
return result A
Else if (CalculationDiluent is null) OR (CalculationConcentration is null) OR
(ValidFcFactorExists is false)
return result C
Else if (CalculationDiluent is equal to 0.0)
return result D
Else
CalculatedUnadjustedValue = CalculationConversionFactor *
Environmental Protection Agency
Page 684 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
CalculationConcentration * CiirrentHourlyOpRecor
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
A
B
C
D
F
Response
You reported an incorrect MODCCode in the MATS Derived Hourly Value record for
[param], as you reported substitute data for one or more essential auxiliary parameters.
You reported an incorrect MODCCode in the MATS Derived Hourly Value record for
[param], as you reported measured data for essential auxiliary parameters.
You reported a Formulaldentifier in the MATS Derived Hourly Value record for
[param], but you did not report a value for all the essential parameters needed to
perform the calculation.
The [param] could not be recalculated, because the diluent value would result in
division by zero.
You did not report a single valid MonitorDefault record for ParameterCode BWA for
the hour.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1 Process/Category:
2 Process/Category:
3 Process/Category:
4 Process/Category:
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
Emissions Data Evaluation Report
MATS HC1RH Calculation Verification
MATS HF RH Calculation Verification
MATS Hg RH Calculation Verification
MATS S02 RH Calculation Verification
Environmental Protection Agency
Page 686 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSCHV-16
Check Name:
Stash Hg Calculated Value
Related Former Checks:
Applicability:
Description:
Specifications:
MatsCalculatedHgRateValue = CalculatedUnadjustedValue (converted to Scientific Notation, with 3 significant digits)
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS Hg RE Calculation Verification
2 Process/Category: Emissions Data Evaluation Report MATS Hg RH Calculation Verification
Environmental Protection Agency
Page 687 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSCHV-17
Check Name:
Stash HC1 Calculated Value
Related Former Checks:
Applicability:
Description:
Specifications:
MatsCalculatedHclRateValue = CalculatedUnadjustedValue (converted to Scientific Notation, with 3 significant digits)
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS HC1 RE Calculation Verification
2 Process/Category: Emissions Data Evaluation Report MATS HC1RH Calculation Verification
Environmental Protection Agency
Page 688 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSCHV-18
Check Name:
Stash HF Calculated Value
Related Former Checks:
Applicability:
Description:
Specifications:
MatsCalculatedHfRateValue = CalculatedUnadjustedValue (converted to Scientific Notation, with 3 significant digits)
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS HF RE Calculation Verification
2 Process/Category: Emissions Data Evaluation Report MATS HF RH Calculation Verification
Environmental Protection Agency
Page 689 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSCHV-19
Check Name:
Stash S02 Calculated Value
Related Former Checks:
Applicability:
Description:
Specifications:
MatsCalculatedSo2RateValue = CalculatedUnadjustedValue (converted to Scientific Notation, with 3 significant digits)
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS S02 RE Calculation Verification
2 Process/Category: Emissions Data Evaluation Report MATS S02 RH Calculation Verification
Environmental Protection Agency
Page 690 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Category:
MATS Derived Hourly Value Checks
Environmental Protection Agency
Page 691 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSDHV-1
Check Name: Initialize HGRE Derived Hourly Value Data
Related Former Checks:
Applicability:
Description:
Specifications:
CurrentDh v Parameter = "HGRE"
MatsDh v Record = MatsHgDh v Record
MatsEquationCodeWithH2o = "A-3"
MatsEquationCodeWithoutH2o = "A-2"
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS Hg RE Derived Hourly Evaluation
Environmental Protection Agency
Page 692 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSDHV-2
Check Name: Initialize HGRH Derived Hourly Value Data
Related Former Checks:
Applicability:
Description:
Specifications:
CurrentDh v Parameter = "HGRH"
MatsDh v Record = MatsHgDh v Record
Results:
Result Response
Usage:
1 Process/Category: Emissions Data Evaluation Report
Severity
MATS Hg RH Derived Hourly Evaluation
Environmental Protection Agency
Page 693 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
Check Name:
Related Former Checks:
Applicability:
Description:
Specifications:
CurrentDh v Parameter = "HCLRE"
MatsDh v Record = MatsHctDh v Record
MatsEquationCodeWithH2o = "HC-3"
MatsEquationCodeWithoutH2o = "HC-2"
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS HC1 RE Derived Hourly Evaluation
MATSDHV-3
Initialize HCLRE Derived Hourly Value Data
Environmental Protection Agency
Page 694 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSDHV-4
Check Name: Initialize HCLRH Derived Hourly Value Data
Related Former Checks:
Applicability:
Description:
Specifications:
CurrentDh v Parameter = "HCLRH"
MatsDh v Record = MatsHctDh v Record
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS HC1RH Derived Hourly Evaluation
Environmental Protection Agency
Page 695 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSDHV-5
Check Name: Initialize HFRE Derived Hourly Value Data
Related Former Checks:
Applicability:
Description:
Specifications:
CurrentDh v Parameter = "HFRE"
MatsDh v Record = MatsHfDh v Record
MatsEquationCodeWithH2o = "HF-3"
MatsEquationCodeWithoutH2o = "HF-2"
Results:
Result Response
Usage:
1 Process/Category: Emissions Data Evaluation Report
Severity
MATS HF RE Derived Hourly Evaluation
Environmental Protection Agency
Page 696 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSDHV-6
Check Name: Initialize HFRH Derived Hourly Value Data
Related Former Checks:
Applicability:
Description:
Specifications:
CurrentI)h v Parameter = "HFRH"
MatsDh v Record = MatsHfDh v Record
Results:
Result Response
Usage:
1 Process/Category: Emissions Data Evaluation Report
Severity
MATS HF RH Derived Hourly Evaluation
Environmental Protection Agency
Page 697 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSDHV-7
Check Name: Initialize S02RE Derived Hourly Value Data
Related Former Checks:
Applicability:
Description:
Specifications:
CurrentDh vParameter = "S02RE"
MatsDh v Record = MatsSo2 Dh v Record
MatsEquationCodeWithH2o = "S-3"
MatsEquationCodeWithoutH2o = "S-2"
Results:
Result Response
Usage:
1 Process/Category: Emissions Data Evaluation Report
Severity
MATS S02 RE Derived Hourly Evaluation
Environmental Protection Agency
Page 698 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSDHV-8
Check Name: Initialize S02RH Derived Hourly Value Data
Related Former Checks:
Applicability:
Description:
Specifications:
CurrentDh vParameter = "S02RH"
MatsDh v Record = MatsSo2 Dh v Record
Results:
Result Response
Usage:
1 Process/Category: Emissions Data Evaluation Report ¦
Severity
MATS S02 RH Derived Hourly Evaluation
Environmental Protection Agency
Page 699 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSDHV-9
Check Name: Check Mats MODC in DHV Records
Related Former Checks:
Applicability:
Description:
Specifications:
DerivedHourlyModcStatus = false
If IV!iitsDhvRecord.ModcCodc not in set {36, 37, 38, 39}
return result A
Else
DerivedHourlyModcStatus = true
Results:
Result Response Severity
A You reported an MODC code that is not valid for the MATS DHV. Critical Error Level 1
Usage:
1
Process/Category:
Emissions Data Evaluation Report —
— MATS HC1 RE Derived Hourly Evaluation
2
Process/Category:
Emissions Data Evaluation Report —
— MATS HC1RH Derived Hourly Evaluation
3
Process/Category:
Emissions Data Evaluation Report —
— MATS HF RE Derived Hourly Evaluation
4
Process/Category:
Emissions Data Evaluation Report —
— MATS HF RH Derived Hourly Evaluation
5
Process/Category:
Emissions Data Evaluation Report —
— MATS Hg RE Derived Hourly Evaluation
6
Process/Category:
Emissions Data Evaluation Report —
— MATS Hg RH Derived Hourly Evaluation
7
Process/Category:
Emissions Data Evaluation Report —
— MATS S02 RE Derived Hourly Evaluation
8
Process/Category:
Emissions Data Evaluation Report —
— MATS S02 RH Derived Hourly Evaluation
Environmental Protection Agency
Page 700 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSDHV-10
Check Name: Check Formula in MATS DHV Record
Related Former Checks:
Applicability:
Description:
Specifications:
DerivedHourlyFormulaStatus = false
If (DerivedHourlyModcStatus = true)
If (MatsDh v Record. Fo rm u 1 a Key is null)
If MatsDhvRecord.ModcCode = "38"
DerivedHourlyFormulaStatus = true
else
return result A
else //FormulaKey not null
If (MatsDhvRecord.ModcCode in set {36, 37, 39})
If (MatsDh vRecord. Fo rm u 1 a A c t i ve I nd is NOT equal to 1)
return result B
Else if (MatsDh vRecord. Fo rmu 1 a Pa ra mc t c rCodc is not equal to CurrentDh vParameter)
return result C
Else if (CurrentDhvParameter in set {"HGRE", "HCLRE", "HFRE", "S02RE"} and MatsDhvRecord.ModcCode
= "37"
return result D
Else if (CurrentDhvParameter in set {"HGRH", "HCLRH", "HFRH", "S02RH"} and
MatsDh v Record. IVI o dc C o dc = "39"
return result E
Else
DerivedHourlyFormulaStatus = true
else //other MODC code (38)
return result F
Results:
Result Response
A You did not report a FormulalD in the MATS DHV record for [param],
B You reported FormulalD [ID] in the MATS DHV record for [param], but there is no
active Formula record for this formula in your monitoring plan.
C You reported FormulalD [ID] in the MATS DHV record for [param], but in your
monitoring plan this formula has a different ParameterCode.
D You reported a MODCCode of 37 for the MATS DHV record, but the use of a diluent
cap value is not applicable to [param],
E You reported a MODCCode of 39 for the MATS DHV record, but the use of a default
electrical load value is not applicable to [param],
F You reported a FormulalD for a MATS DHV record, that is not reported if valid
concentration was not available or substitute data reported for one or more essential
auxiliary parameters.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 701 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Usage:
1
Process/Category:
Emissions Data Evaluation Report —
— MATS HC1 RE Derived Hourly Evaluation
2
Process/Category:
Emissions Data Evaluation Report —
— MATS HC1RH Derived Hourly Evaluation
3
Process/Category:
Emissions Data Evaluation Report —
— MATS HF RE Derived Hourly Evaluation
4
Process/Category:
Emissions Data Evaluation Report —
— MATS HF RH Derived Hourly Evaluation
5
Process/Category:
Emissions Data Evaluation Report —
— MATS Hg RE Derived Hourly Evaluation
6
Process/Category:
Emissions Data Evaluation Report —
— MATS Hg RH Derived Hourly Evaluation
7
Process/Category:
Emissions Data Evaluation Report —
— MATS S02 RE Derived Hourly Evaluation
8
Process/Category:
Emissions Data Evaluation Report —
— MATS S02 RH Derived Hourly Evaluation
Environmental Protection Agency
Page 702 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSDHV-11
Check Name:
Check Equation Code for MATS RE
Related Former Checks:
Applicability:
Description:
Specifications:
DerivedHourlyEquationStatus = false
If (DerivedHourlyFormulaStatus == true)
If (MatsDh vRecord. Equat io nCodc is not null)
If (MatsDh vRecord. EquationCodc == MatsEquationCodeWithoutH2o)
DerivedHourlyEquationStatus = true
FlowMonitorHourlyChecksNeeded = true
Else If (MatsDh vRecord. EquationCodc == MatsEquationCodeWithH2o)
Derived Hourly Equation Status = true
Flow Monitor Hourly Checks Needed = true
Moisture Needed = true
append "MIN" to H20MissingDataApproach
Else
return result A
Else
DerivedHourlyEquationStatus = true
Results:
Result
A
Response
You reported a formula code that does not match any of the MATS derived hourly
value formulas.
Severity
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS HC1 RE Derived Hourly Evaluation
2 Process/Category: Emissions Data Evaluation Report MATS HF RE Derived Hourly Evaluation
3
Process/Category: Emissions Data Evaluation Report MATS Hg RE Derived Hourly Evaluation
4 Process/Category: Emissions Data Evaluation Report MATS S02 RE Derived Hourly Evaluation
Environmental Protection Agency
Page 703 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
Check Code: MATSDHV-12
Check Name: Check Equation Code for MATS RH
Related Former Checks:
Applicability:
Description:
Specifications:
DerivedHourlyEquationStatus = false
If (DerivedHourlyFormulaStatus == true)
If (MatsDh vRecord. Equat io nCodc is not null)
If (MatsDhvRecord.EquationCode in set {19-1, 19-2, 19-3, 19-3D, 19-4, 19-5, 19-5D, 19-6, 19-7, 19-8, 19-9} )
DerivedHourlyEquationStatus = true
If (MatsDh vRecord. Equat io nCodc in set {19-1, 19-4} )
02DryNeededForMats = true
FDFactorNeeded = true
Else if {MatsDhvTtecwrf.EquationCode in set {19-3,19-3D, 19-5, 19-5D})
()2 WetNeededForMats = true
FDFactorNeeded = true
Else if (MatsDh vRecord. Equat io nCodc in set {19-2} )
()2 WetNeededForMats = true
FWFactorNeeded = true
Else if (MatsDh v Record. Equat io nCodc inset {19-6, 19-7, 19-8, 19-9} )
C02DiluentNeededForMats = true
FCFactorNeeded = true
If (MatsDhvRecord.EquationCodc inset {19-3, 19-3D, 19-4, 19-5, 19-8, 19-9}
MoistureNeeded = true
Else
return result A
Else
DerivedHourlyEquationStatus= true
Results:
Result Response Severity
A You reported a formula code that does not match any of the MATS derived hourly Critical Error Level 1
value formulas.
Usage:
1
Process/Category:
Emissions Data Evaluation Report
2
Process/Category:
Emissions Data Evaluation Report
3
Process/Category:
Emissions Data Evaluation Report
4
Process/Category:
Emissions Data Evaluation Report
Environmental Protection Agency
Page 704 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSDHV-13
Check Name:
Complete HGRE and HGRH Derived Hourly Value
Related Former Checks:
Applicability:
Description:
Specifications:
MatsHgDhvParameter = Cur rentI)h v Parameter
MatsHgDhvValid = DerivedHourlyEquationStatus AND DerivedHourlyUnadjustedValueStatus
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS Hg RE Derived Hourly Evaluation
2
Process/Category: Emissions Data Evaluation Report MATS Hg RH Derived Hourly Evaluation
Environmental Protection Agency
Page 705 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSDHV-14
Check Name: Complete HCLRE and HCLRH Derived Houly Value
Related Former Checks:
Applicability:
Description:
Specifications:
MatsHclDhvParameter = CurrentDh vParameter
MatsHclDhvValid = DerivedHourlyEquationStatus AND DerivedHourlyUnadjustedValueStatus
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS HC1 RE Derived Hourly Evaluation
2 Process/Category: Emissions Data Evaluation Report MATS HC1RH Derived Hourly Evaluation
Environmental Protection Agency
Page 706 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSDHV-15
Check Name:
Complete HFRE and HFRH Derived Hourly Value
Related Former Checks:
Applicability:
Description:
Specifications:
MatsHfDhvParameter = CurrentDh v Parameter
MatsHfDhvValid = DerivedHourlyEquationStatus AND DerivedHourlyUnadjustedValueStatus
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS HF RE Derived Hourly Evaluation
2 Process/Category: Emissions Data Evaluation Report MATS HF RH Derived Hourly Evaluation
Environmental Protection Agency
Page 707 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSDHV-16
Check Name: Complete S02RE and S02RH Derived Hourly Value
Related Former Checks:
Applicability:
Description:
Specifications:
MatsSo21)h v Parameter = Cur rentI)h v Parameter
MatsSo2DhvValid = DerivedHourlyEquationStatus AND DerivedHourlyUnadjustedValueStatus
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS S02 RE Derived Hourly Evaluation
2 Process/Category: Emissions Data Evaluation Report MATS S02 RH Derived Hourly Evaluation
Environmental Protection Agency
Page 708 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSDHV-17
Check Name:
Check Unadjusted Value
Related Former Checks:
Applicability:
Description:
Specifications:
DerivedHourlyUnadjustedValueStatus = false
If (DerivedHourlyModcStatus = true)
If (MatsDhvRecord.ModcCode in set {36, 37, 39})
If (MatsDhvRecord.UnadjustedHourly Value is null)
return result A
Else if (MatsDh vRecord. U nadj ustedHourly Value is NOT reported in scientific notation to three significant digits)
return result B
Else if (MatsDh vRecord. U nadj ustedHourly Value <0)
return result C
Else
DerivedHourlyUnadjustedValueStatus = true
Else//MODC38
If (MatsDh vRecord. U nadj ustedHourly Value is not null)
return result D
Else
DerivedHourlyUnadjustedValueStatus = true
Results:
Result
A
B
Response
You did not provide a [fieldname], which is required, for [key].
The [fieldname] value in the [key] records is not reported in scientific notation rounded
to three significant figures, with one digit to the left of the decimal point.
You reported a negative value, which is invalid, in the field [fieldname] for [key].
You reported an UnadjustedHourly Value for a MATS DHV record, that is not reported
if a valid concentration was not available or substitute data reported for one or more
essential auxiliary parameters.
Severity
Critical Error Level 1
Critical Error Level 1
C
D
Critical Error Level 1
Critical Error Level 2
Environmental Protection Agency
Page 709 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Usage:
1
Process/Category:
Emissions Data Evaluation Report —
— MATS HC1 RE Derived Hourly Evaluation
2
Process/Category:
Emissions Data Evaluation Report —
— MATS HC1RH Derived Hourly Evaluation
3
Process/Category:
Emissions Data Evaluation Report —
— MATS HF RE Derived Hourly Evaluation
4
Process/Category:
Emissions Data Evaluation Report —
— MATS HF RH Derived Hourly Evaluation
5
Process/Category:
Emissions Data Evaluation Report —
— MATS Hg RE Derived Hourly Evaluation
6
Process/Category:
Emissions Data Evaluation Report —
— MATS Hg RH Derived Hourly Evaluation
7
Process/Category:
Emissions Data Evaluation Report —
— MATS S02 RE Derived Hourly Evaluation
8
Process/Category:
Emissions Data Evaluation Report —
— MATS S02 RH Derived Hourly Evaluation
Environmental Protection Agency
Page 710 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Category:
MATS Hourly GFM Data
Environmental Protection Agency
Page 711 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSGFM-1
Check Name: Component ID Valid
Related Former Checks:
Applicability:
Description:
Specifications:
Set MatsHourlyGFMComponentldValid = false.
Set MatsSamplingTrainRecord to null.
Set MatsSamplingTrainQaStatus to null.
Set MatsSorbentTrapBeginDateHour to null.
Set MatsSorbentTrapEndDateHour to null.
Set MatsSamplingTrainCount to null.
If the MatsHourlyGFMRecord.ComponentlD is null,
Return result A.
Else
Locate MatsSamplingTrainRecords where:
1) Componentld is equal to MatsHourlyGFMRecord. Co mpo nc lit ID
2) SorbentTrapBeginDateHour is on or before CurrentDateHour
3) SorbentTrapEndDateHour is on or after CurrentDateHour
4) Records are sorted by SorbentTrapBeginDateHour and SorbentTrapEndDateHour // The earliest sampling train is the correct
train.
Set MatsSamplingTrainCount to the number of records located in MatsSamplingTrainsRecords.
If not found,
Locate an entry in the element in MatsSorbentTrapListByLocationArray for CurrentMonitorPlanLocationPosition
where:
1) SorbentTrapForQuarterBorder is true.
2) SorbentTrapBeginDateHour is on or before CurrentDateHour.
3) SorbentTrapEndDateHour is on or after CurrentDateHour.
If not found,
Return result B.
Else
Set MatsHourlyGFMComponentldValid to true.
Set MatsSamplingTrainRecord to the first record located in MatsSamplingTrainsRecords.
Set MatsSamplingTrainQaStatus to MatsSamplingTrainRecord.TramQAStatusCode.
Set MatsSorbentTrapBeginDateHour to MatsSampling Train Record. B eg i n Date H o u r.
Set MatsSorbentTrapEndDateHour to MatsSamplingTrainRecordEndDateRom:.
Environmental Protection Agency
Page 712 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
B
Usage:
1
Response
You did not report a [fieldname] value in the [key] records which is required if the
sorbent train QA Status Code is PASSED, FAILED, or UNCERTAIN, and the stack
flow rate for the hour is a measured data value.
For [key], you reported a sorbent train GFM Component ID that does not match a
sorbent train Component ID record.
Severity
Critical Error Level 1
Critical Error Level 1
Process/Category: Emissions Data Evaluation Report MATS Hourly Gas Flow Meter Evaluation
Environmental Protection Agency
Page 713 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSGFM-2
Check Name: Begin and End Hour Flags Valid
Related Former Checks:
Applicability:
Description:
Specifications:
If MatsHourlyGFMComponentldValid is true,
If Hourly(iFMData B eg i n E ndH o u rF 1 ag is "I",
If CurrentDateHour is not equal to the MatsSorbentTrapBeginDateHour and is not the hour after the
MatsSorbentTrapBeginDateHour.
Return result A
Else if the Hourly (iFMData. B eg i n E ndH o u rF 1 ag is "F",
If CurrentDateHour is not equal to theMatsSorbentTrapEndDateHour and is not the hour before the
MatsSorbentTrapEndDateHour,
Return result B.
Else if Hourly (i FMI) at a B eg i n E ndH o u rF 1 ag is null,
If CurrentDateHour is on the MatsSorbentTrapBeginDateHour,
Return result C.
Else if CurrentDateHour is on the MatsSorbentTrapEndDateHour,
Return result D.
Else if //owr/jGFMDafa.BeginEndHourFlag is "T",
If MatsSamplingTrainCount is less than or equal to 1,
// No transition overlap between sorbent traps
Return result E.
Else if CurrentDateHour is not equal to the MatsSorbentTrapEndDateHour
II Current hour is not the end hour of the current sorbent trap
Return result F.
Environmental Protection Agency
Page 714 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result Response Severity
A For [key], you identified a begin hour that is not the first or second hour of the sampling Critical Error Level 1
period.
B For [key], you identified an end hour that is not the last or second to the last hour of the Critical Error Level 1
sampling period.
C For [key], you did not identify the first hour of the sampling period as a begin or Critical Error Level 1
transition hour.
D For [key], you did not identify the last hour of the sampling period as an end or Critical Error Level 1
transition hour.
E For [key], you identified an hour as a transition hour, but the hour is not included in two Critical Error Level 1
consecutive sampling periods.
F For [key], you identified a transition hour that is not the last hour of a sampling period. Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS Hourly Gas Flow Meter Evaluation
Environmental Protection Agency
Page 715 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSGFM-3
Check Name: Hourly GFM Reading Valid
Related Former Checks:
Applicability:
Description:
Specifications:
If MatsHourlyGFMComponentldValid is true,
If the MatsHourlyGFMRecordMowlyGFMReading is null,
If the MiitsSamplingTrainOaStatus is not "INC", "EXPIRED", or "LOST",
Return result A.
Else,
If the MatsSampling Train OaStatus is not "PASSED", "FAILED", or "UNCERTAIN",
Return result B.
Else if the MatsHourlyGFMRecord.HourlyGFMReadmg is not reported to two decimal places ,
Return result C.
Results:
Result
B
C
Usage:
1
Response
You did not report a [fieldname] value in the [key] records which is required if the
sorbent train QA Status Code is PASSED, FAILED, or UNCERTAIN, and the stack
flow rate for the hour is a measured data value.
You reported a [fieldname] value in the [key] records which is reported only if the
sorbent train QA Status Code is PASSED, FAILED, or UNCERTAIN, and the stack
flow rate for the hour is a measured data value.
For [key], the [fieldname] value is not reported to two decimal places.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Process/Category: Emissions Data Evaluation Report MATS Hourly Gas Flow Meter Evaluation
Environmental Protection Agency
Page 716 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSGFM-4
Check Name: Average Hourly Sampling Rate Valid
Related Former Checks:
Applicability:
Description:
Specifications:
If MatsHourlyGFMComponentldValid is true,
If the MatsHourlyGFMRecord.AvgHourlySamplingRate is null,
If the MatsSamplingTrainQaStatus is not "INC", "EXPIRED", or "LOST",
Return result A.
Else,
If the MatsSamplingTrainQaStatus is not "PASSED", "FAILED", or "UNCERTAIN",
Return result B.
Else if the MatsHourlyGFMRecorcl. AvgHourhSmnpWngR'Mc is not reported to two decimal places ,
Return result C.
Results:
Result
A
B
C
Response
You did not report a [fieldname] value in the [key] records which is required if the
sorbent train QA Status Code is PASSED, FAILED, or UNCERTAIN, and the stack
flow rate for the hour is a measured data value.
You reported a [fieldname] value in the [key] records which is reported only if the
sorbent train QA Status Code is PASSED, FAILED, or UNCERTAIN, and the stack
flow rate for the hour is a measured data value.
For [key], the [fieldname] value is not reported to two decimal places.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1
Process/Category: Emissions Data Evaluation Report MATS Hourly Gas Flow Meter Evaluation
Environmental Protection Agency
Page 717 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
Check Name:
Related Former Checks:
Applicability:
Description:
Specifications:
If MatsHourlyGFMComponentldValid is true,
If the MatsHourlydFMRecord.SampWngR-MciJOM is null,
If the MatsSamplingTrainQaStatus is not "INC", "EXPIRED", or "LOST",
Return result A.
MATSGFM-5
Sampling Rate UOM Valid
Else,
If the MatsSamplingTrainQaStatus is not "PASSED", "FAILED", or "UNCERTAIN",
Return result B.
Else if the MatsHourlyGFMRecord.SamplingRateUOM is not "CCMIN", "DSCMMIN', "LMIN", "CCHR",
"DSCMHR", or "LHR" ,
Return result C.
Results:
Result
A
B
C
Response
You did not report a [fieldname] value in the [key] records which is required if the
sorbent train QA Status Code is PASSED, FAILED, or UNCERTAIN, and the stack
flow rate for the hour is a measured data value.
You reported a [fieldname] value in the [key] records which is reported only if the
sorbent train QA Status Code is PASSED, FAILED, or UNCERTAIN, and the stack
flow rate for the hour is a measured data value.
For [key] you reported a [value] which is not valid for [fieldname].
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1
Process/Category: Emissions Data Evaluation Report MATS Hourly Gas Flow Meter Evaluation
Environmental Protection Agency
Page 718 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSGFM-6
Check Name:
Hourly SFSR Ratio Valid
Related Former Checks:
Applicability:
Description:
Specifications:
If the MatsHourlydFMRecord.HourlySFSRRatio is null,
If MatsSamplingTrainQaSiatus is not "INC", "EXPIRED", or "LOST", AND CurrentStackFlowHourlyRecord is NOT null
AND CurrentStackFlowHourly Record. ModcCode in set {01, 02, 03, 04, 20, 53, 54},
Else,
If MatsSamplingTrainQaStatus is not "PASSED", "FAILED", or "UNCERTAIN",
Return result B.
Else if CurrentStackFlowHourlyRecord is null,
Return result F.
Else if CurrentStackFlowHourlyRecord ModcCode NOT in set {01, 02, 03, 04, 20, 53, 54},
Return result E.
Else if the the MatsHourlydFMRecord. H ourly S F S R Rat io is not reported to one decimal place ,
Return result C..
Else if the MatsHourlyGFMRecord.Hourly SFSRRatio is not greater than or equal to 1.0 and less than or equal to 100.0,
Return result D.
Else if MatsHourlyGFMComponentldValid is true AND MatsSamplingTrainDictionary contains a key equal to
MatsSampllng Train Record. T ra i n ID AND MatsSampling Train Dictionary. Rc fc rc ncc S F S R Ra t i o where the key equals
MatsSampling Train Record. T ra i n ID is NOT null or equal to 0,
Set MatsHourlySfsrRatioDeviation to absolute value of [1 - (MatsHourlydFMRecord. H ourly S FS R Rat io /
MatsSamplingTrainDictionary. ReferenceSFSRRatio where the key equals MatsSamplingTrainRecord^ rainID) | x 100,
rounded to an integer.
Add one to MatsSamplingTrainDictionary.TotalSFSRRatioCount where the key equals
MatsSamplingTrainRecord. T rainID
If the MatsHourlySfsrRatioDeviation is greater than 25,
Add one to MatsSamplingTrainDictionary.DeviatedSFSRRatioCount where the key equals
MatsSamplingTrainRecord. T rainID
Return result A.
Environmental Protection Agency
Page 719 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
B
C
D
E
Usage:
1
Response
You did not report a [fieldname] value in the [key] records which is required if the
sorbent train QA Status Code is PASSED, FAILED, or UNCERTAIN, and the stack
flow rate for the hour is a measured data value.
You reported a [fieldname] value in the [key] records which is reported only if the
sorbent train QA Status Code is PASSED, FAILED, or UNCERTAIN, and the stack
flow rate for the hour is a measured data value.
The [fieldname] value for [key] should be reported to one decimal place.
The [fieldname] value for [key] must be a number between 1 and 100.
You reported a [fieldname] value in the [key] records which is not reported if the stack
gas flow rate for the hour is a substitute data value.
You reported a [fieldname] value in the [key] records which you should not report
when a stack gas flow rate is not reported for the hour.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Process/Category: Emissions Data Evaluation Report MATS Hourly Gas Flow Meter Evaluation
Environmental Protection Agency
Page 720 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Category:
MATS Monitor Hourly Value Checks
Environmental Protection Agency
Page 721 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSMHV-1
Check Name:
MATS HgC: Initialize
Related Former Checks:
Applicability:
Description:
Specifications:
Set CurrentMh v Parameter to "HGC"
Set MatsMh vRecord to MatsHgcMh vRecord
If (MatsHgcMhvRecord.SystemTypeCode is equal to "ST")
Set CurrentMhvSystemType to "ST"
Set CurrentMhvComponentType to "STRAIN"
Set MatsMhvMeasuredModd 1st to {01, 02, 32, 33, 41, and 42}
Else
Set CurrentMhvSystemType to "HG"
Set CurrentMhvComponentType to "HG"
Set MatsMhvMeasuredModcList to {01, 02, 17, and 21}
Set McitsMhvUnavailahleModc/Jst to {34 and 35}
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS Hg Concentration Monitor Hourly Evaluation
Environmental Protection Agency
Page 722 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSMHV-2
Check Name: MATS HC1C: Initialize
Related Former Checks:
Applicability:
Description:
Specifications:
Set CurrentMhv Parameter to "HCLC"
Set MatsMh vRecord to MatsHctcMh vRecord
Set CurrentMhvComponentType to "HCL"
Set CurrentMh vSystem Type to" H CL"
Set MatsMhvMeasuredModcList to {01, 02, 17, and 21}
Set MatsMhvUnavaikibleModcList to {34 and 35}
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS HC1 Concentration Monitor Hourly Evaluation
Environmental Protection Agency
Page 723 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSMHV-3
Check Name: MATS HFC: Initialize
Related Former Checks:
Applicability:
Description:
Specifications:
Set CurrentMh v Parameter to "HFC"
Set MatsMh vRecord to MatsHfcMh vRecord
Set CurrentMhvComponentType to "HF"
Set CurrentMhvSystemType to "HF"
Set MatsMhvMeasuredModd 1st to {01, 02, 17 and 21}
Set MatsMhvUnavaikibleModcList to {34 and 35}
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS HF Concentration Monitor Hourly Evaluation
Environmental Protection Agency
Page 724 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSMHV-4
Check Name: MATS: Check MODC
Related Former Checks:
Applicability:
Description:
Specifications:
Set MonitorHourlyModcStatus to false.
If (MatsMhvRecord.ModcCode is null)
return result A
Else if (MatsMh v Record. Mode Code not in MatsMhvMeasuredModcList AND not in MatsMhvUnavailableModcList)
return result B
Else if (CurrentMhvSystemType is equal to "ST") AND (MatsMhvRecord.ModcCode is NOT equal to "41" or "42")
Locate MatsSorbentTrapRecords where:
1) Systemld is equal to MatsMhvRecord. SystemID
2) BeginDateHour is on or before CurrentDateHour
3) EndDateHour is on or after CurrentDateHour
4) Records are sorted by BeginDateHour and EndDateHour // The earliest sorbent trap is the correct trap.
If found,
For the first located record in MatsSorbentTrapRecords
If (ModcCode is NOT null) AND (MatsMhvRecord.ModcCode is NOT equal to ModcCode)
return result C
Else
MonitorHourlyModcStatus = true
Else
MonitorHourlyModcStatus = true
Else
MonitorHourlyModcStatus = true
Results:
Result
A
B
C
Response
You did not provide a [fieldname], which is required, for [key].
The MODCCode reported for MATS Monitor Hourly Value is invalid.
The MODCCode reported for MATS Monitor Hourly Value is invalid for Hg sorbent
trap systems.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 725 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS HC1 Concentration Monitor Hourly Evaluation
2 Process/Category: Emissions Data Evaluation Report MATS HF Concentration Monitor Hourly Evaluation
3 Process/Category: Emissions Data Evaluation Report MATS Hg Concentration Monitor Hourly Evaluation
Environmental Protection Agency
Page 726 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSMHV-5
Check Name: MATS: Check Percent Monitor Availability
Related Former Checks:
Applicability:
Description:
Specifications:
Set MonitorHourlyPmaStatus = false
If (MonitorHourlyModcStatus == true)
If ( MatsMh v Record. Pc rcc lit Ay a i lab lc is NULL)
return result A
Else if (MatsMh vRecord. Pcrccnt Ayai 1 ab 1 c> 100.0 OR MatsMh vRecord.Pcrccnt Ayai 1 ab 1 c <0.0)
return result B
Else
Set MonitorHourlyPmaStatus = true
Results:
Result Response Severity
A You did not report a PMA for the MATS Monitor Hourly Value. Critical Error Level 1
B The PMA must be in a range from 0 to 100. Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS HC1 Concentration Monitor Hourly Evaluation
2 Process/Category: Emissions Data Evaluation Report MATS HF Concentration Monitor Hourly Evaluation
3 Process/Category: Emissions Data Evaluation Report MATS Hg Concentration Monitor Hourly Evaluation
Environmental Protection Agency
Page 727 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSMHV-6
Check Name: MATS: Monitoring System
Related Former Checks:
Applicability:
Description:
Specifications:
Set MonitorHourlySystemStatus = false
If (MonitorHourlyModcStatus == true)
If (MatsMh v Record. Mode Code in MatsMhvMeasuredModcList)
If MatsMh vRecord. MonitoringSystemID is null
return result A
Else if MatsMh vRecord. Sy s te m I de n t i fi e r is null
return result B
Else if (MatsMh vRecord. SystcmTypcCodc <> CurrentMhvSystemType)
return result C
Else
MonitorHourlySystemStatus = true
Else // Unavailable MODC
If (MatsMh vRecord. IVIo ni to ri ngSy stem ID is NOT null)
return result D
Else
MonitorHourlySystemStatus = true
Results:
Result
A
B
C
D
Severity
Critical Error Level 1
Critical Error Level 1
Response
You did not report a MonitoringSystemID for the [param] MATS Monitor Hourly
Value.
You reported MonitoringSystemID [ID] in the MATS MHV record for [param], but
there is no Monitoring System recored for this system in your monitoring plan that was
active during the hour.
The system type associated with the Monitoring System ID for the [param] MATS
Monitor Hourly Value is not consistent with that parameter.
You reported a MonitoringSystemID for the [param] MATS Monitor Hourly Value that Critical Error Level 1
is not reported based on the MODCCode.
Critical Error Level 1
Environmental Protection Agency
Page 728 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS HC1 Concentration Monitor Hourly Evaluation
2 Process/Category: Emissions Data Evaluation Report MATS HF Concentration Monitor Hourly Evaluation
3 Process/Category: Emissions Data Evaluation Report MATS Hg Concentration Monitor Hourly Evaluation
Environmental Protection Agency
Page 729 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSMHV-7
Check Name: MATS: System Designation
Related Former Checks:
Applicability:
Description:
Specifications:
If (MonitorHourlyModcStatus == true AND MonitorHourlySystemStatus == true AND McitsMh vRecord. S y s t e m I dc n t i fi e r is not null)
case (MatsMh v Record. Mode Code)
01 OR 17: If (MatsMhvRecord.SystcmDcsignationCodc <> "P")
return result A
02: If (MatsMhvRecord.SystcmDcsignationCodc NOT in set {B, RB}
return result B
Results:
Result Response Severity
A You reported a MATS Hourly Value MODCCode that is only used with primary or Critical Error Level 1
temporary like kind monitoring systems.
B You reported a MATS Monitor Hourly Value MODCCode that is only used with Critical Error Level 1
backup or redundant backup monitoring systems.
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS HC1 Concentration Monitor Hourly Evaluation
2 Process/Category: Emissions Data Evaluation Report MATS HF Concentration Monitor Hourly Evaluation
3 Process/Category: Emissions Data Evaluation Report MATS Hg Concentration Monitor Hourly Evaluation
Environmental Protection Agency
Page 730 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSMHV-8
Check Name: MATS: Check Like Kind Analyzer Use
Related Former Checks:
Applicability:
Description:
Specifications:
If (MonitorHourlyModcStatus == true AND MonitorHourlySystemStatus == true)
If (MatsMhvRecord.ModcCode == "17")
HoursOjUseOfLikeKindAnalyzer = Count of MonitorHourly ValueData records for the location and reporting period where:
1) ParameterCode = CurrentMhvParameter
2) ModcCode == "17"
3) BeginDateHour < CurrentOperatingDateHour
If HoursOjUseOfLikeKindAnalyzer >= 720
FirstUseOfLikeKindAnalyzerRecord = MonitorHourly ValueData record at earliest time for the location and
reporting period where:
1) ParameterCode = CurrentMhvParameter
2) ModcCode == "17"
3) BeginDateHour < CurrentOperatingDateHour
Locate a RATATestRecordsByLocationForQAStatus for the location where:
1) MonitoringSystemID is equal to McitsMh vRecord. M o n i t o ri ng S y s t e m ID
2) TestResultCode begins with "PASS"
3) EndDate/EndHour is after the FirstUseOfLikeKindAnalyzerRecord.Date/Hour and on or prior to the
CurrentOperatingDateHour.
If not found,
return result A
Results:
Result Response
A You reported an MODCCode of 17 in the MATS Monitor Hourly Value record for
[param], indicating the use of a like-kind analyzer, but you have used a like-kind
analyzer to monitor this parameter for more than 720 hours during this reporting period
You are not allowed to use a like-kind analyzer for more than 720 hours during a
calendar year, unless the analyzer is identified as a non-redundant backup and a RATA
is performed.
Usage:
1 Process/Category:
2 Process/Category:
3 Process/Category:
Seventy
Critical Error Level 1
Emissions Data Evaluation Report MATS HC1 Concentration Monitor Hourly Evaluation
Emissions Data Evaluation Report MATS HF Concentration Monitor Hourly Evaluation
Emissions Data Evaluation Report MATS Hg Concentration Monitor Hourly Evaluation
Environmental Protection Agency
Page 731 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSMHV-9
Check Name:
MATS: Component
Related Former Checks:
Applicability:
Description:
Specifications:
MonitorHourlyComponentStatus = false
If (CurrentMhvSystemType <> "ST")
If (MonitorHourlyModcStatus = true)
If (MatsMh v Record. Mode Code in set MatsMhvMeasuredModcList)
If MatsMh vRecord. Co mpo ne lit ID is null
return result A
If MatsMh vRecord. C o m po nc n 11 dc n t i fi c r is null
return result B
Else if (MatsMh vRecord. Co mpo ncntTy pcCodc <> CurrentMhvComponentType)
return result C
Else if MatsMh vRecord. ModcCodc == 17 AND MafsMAvTtecon/.Componentldentifier does not begin
with "LK"
return result D
Else
Else
MonitorHourlyComponentStatus = true
Else
If MatsMh vRecord. Co mpo ne lit ID is NOT null
return result E
Else
MonitorHourlyComponentStatus = true
Else
If MatsMh vRecord. Co mpo ncnt ID is NOT null
return result F
Else
MonitorHourlyComponentStatus = true
Environmental Protection Agency
Page 732 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
A
B
C
D
E
F
Usage:
1
Response
You did not report a ComponentID for the [param] MATS Monitor Hourly Value.
Your reported ComponentID [ID] in the MATS MHV record for [param], but there is
no Component record for this component in your monitoring plan.
The component type associated with the ComponentID for the [param] MATS Monitor
Hourly Value is not consistent with the parameter.
You reported an MODCCode of 17 in the MATS MHV record for [param], which
indicates that the component is a like-kind analyzer, but the ComponentID does not
begin with LK.
You reported a ComponentID for the [param] MATS Monitor Hourly Value that is not
reported based on the MODCCode.
You reported a ComponentID in the MATS MHV record for a [type] system, but a
ComponentID is only reported for a gas CEMS.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Process/Category: Emissions Data Evaluation Report MATS HC1 Concentration Monitor Hourly Evaluation
Process/Category: Emissions Data Evaluation Report MATS HF Concentration Monitor Hourly Evaluation
Process/Category: Emissions Data Evaluation Report MATS Hg Concentration Monitor Hourly Evaluation
Environmental Protection Agency
Page 733 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSMHV-10
Check Name:
MATS: System Component
Related Former Checks:
Applicability:
Description:
Specifications:
If (MonitorHourlySystemStatus == true) AND (MatsMh vRecord. Mo ni to ri ngSy stc m ID is not null) AND
(MonitorHourlyComponentStatus == true) AND (MatsMh vRecord. Co mpo ncnt ID is not null)
CountMonSysCompRecord = count MonitoringSystemComponentByHourLocation records where:
1) MonitoringSystemID = MatsMh v Record. IVI o n i to ri ng Sy s t c m ID
2) ComponentID = MatsMh vRecord. Co mpo ncnt ID
If CountMonSysCompRecord = 0
return result A
Results:
Result
A
You reported MonitoringSystemID [sys] ComponentID [ID] in the MATS MHV record Critical Error Level 1
for [param], but there is no MonitorSystemComponent record for this system and
component in your monitoring plan that was active during the hour.
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS HC1 Concentration Monitor Hourly Evaluation
2 Process/Category: Emissions Data Evaluation Report MATS HF Concentration Monitor Hourly Evaluation
3
Process/Category: Emissions Data Evaluation Report MATS Hg Concentration Monitor Hourly Evaluation
Environmental Protection Agency
Page 734 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSMHV-11
Check Name: MATS: Max/Min Value
Related Former Checks:
Applicability:
Description:
Specifications:
CurrentMHVMaxMin Value = null
If (MonitorHourlyModcStatus == true AND MatsMh v Record. Mode Code in set MatsMhvMeasuredModcList)
If (CurrentMhvComponentType == "HG")
MonitorSpanRecordCount = Find active MonitorSpanRecordByHourAndLocation where:
1) ComponentTypeCode = CurrentMhvComponentType AND
2) SpanScaleCode = "H"
If {MonitorSpanRecordCount > 1)
return result A
Else if (MonitorSpanRecordCount = 0)
return result B
Else
CurrentMonitorSpanRecord = the single matched record
If CurrentMonitorSpanRecord.MPCValue > 0)
CurrentMhvMaxMinValue = CurrentMonitorSpanRecord.MPCValuQ
Else
return result C
Results:
Result Response Severity
A You have more than one active High Range SpanScaleCode at the current location for Critical Error Level 1
the hour.
B You have no active High Range SpanScaleCode at the current location for the hour. Critical Error Level 1
C The value in the reported span record for [param] is invalid. Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS HC1 Concentration Monitor Hourly Evaluation
2 Process/Category: Emissions Data Evaluation Report MATS HF Concentration Monitor Hourly Evaluation
3 Process/Category: Emissions Data Evaluation Report MATS Hg Concentration Monitor Hourly Evaluation
Environmental Protection Agency
Page 735 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSMHV-12
Check Name:
Related Former Checks:
MATS: Unadjusted Value
Applicability:
Description:
Specifications:
MonitorHourlyUnadjustedValueStatus = false
Mats Mil vCalculated Value = null
If (MonitorHourlyModcStatus == true)
Case (MatsMh vRecord. ModcCodc)
= 21: MatsMhvCalculatedValue = 0.00E0
If (MatsMh vRecord. U nadj ustedHourly Value == 0)
MonitorHourlyUnadjustedValueStatus = true
Else
return result A
= All Other Codes:
If (MatsMhvRecord.ModcCode in set MatsMhvMeasuredModcList)
If (MatsMh vRecord. U nadj ustcdHourly Value is null)
return result B
Else if (MatsMh vRecord. U nadj ustedHourly Val uc is not reported in scientific notation to three significant
digits)
return result C
Else if (MatsMh vRecord. U nadj ustedHourly Va 1 uc < 0)
return result D
MonitorHourlyUnadjustedValueStatus = true
MatsMhvCalculatedValue = A/aivA/Av/fecvMY/.U nadj ustedHourly Value
If (CurrentMhvMaxMinValue is not null AND MatsMh vRecord. U nadj ustcdH ourly Value >
CurrentMhvMaxMin Value)
return result E
Else
Else
If (A/aivA/Av/tecvw/.U nadj ustedHourly Value is not null)
return result F
Environmental Protection Agency
Page 736 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result Response Severity
A You reported an MODCCode of 21 in the MATS Monitor Hourly Value record for Critical Error Level 1
[param], but the UnadjustedHourlyValue does not equal 0.
B You reported a measured value MODCCode in the MATS Monitor Hourly Value Critical Error Level 1
record for [param] but did not report an UnadjustedHourlyValue.
C The [fieldname] value in the [key] records is not reported in scientific notation rounded Critical Error Level 1
to three significant figures, with one digit to the left of the decimal point.
D You reported a negative value, which is invalid, in the field [fieldname] for [key]. Critical Error Level 1
E Warning: The UnadjustedHourlyValue reported in the MATS MHV record for [param] Informational Message
is in excess of the maximum value listed in the monitoring plan. Sources are required
to periodically (at least once annually) evaluate the appropriateness of these maximum
values in the monitoring plan and make proper adjustments when necessary.
Adjustments may include the need to update range values. You should investigate the
cause of these exceedances and determine whether adjustments to your monitoring
systems or monitoring plan are necessary.
F You did not report a measured value MODCCode in the MATS Monitor Hourly Value Critical Error Level 1
record for [param], but did report an UnadjustedHourlyValue.
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS HC1 Concentration Monitor Hourly Evaluation
2 Process/Category: Emissions Data Evaluation Report MATS HF Concentration Monitor Hourly Evaluation
3 Process/Category: Emissions Data Evaluation Report MATS Hg Concentration Monitor Hourly Evaluation
Environmental Protection Agency
Page 737 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSMHV-13
Check Name:
MATS: QA Status Required and QA Status Parameters
Related Former Checks:
Applicability:
Description:
Specifications:
Set QaStatusComponentld = MatsMh vRecord. Co mpo lie lit Id
Set QaStatusComponentldentifier = MatsMh v Record. Co mpo lie lit I dc nti ficr
Set QaStatusComponentTypeCode = MatsMh vRecord. CompolientTy pcCodc
Set QaStatusSystemDesignationCode = MatsMh vRecord. Sy s t c ill D c s i g na t i o n C o dc
Set QaStatusSystemld = MatsMh vRecord. Sy stc 1111d
Set QaStatusSystemldentifier = MatsMh v Record. Sy s t c 1111 dc 111 i fi c r
Set QaStatusSystemTypeCode = MatsMh vRecord. Sy stcniTypcC0dc
Set DailyCalStatusRequired = false.
Set LinearityStatusRequired = false.
Set QuarterlyGasAuditStatus = false.
Set RataStatusRequired = false.
Set WsiStatusRequired = false.
if (Monitor Hour lyModcStatus == true) AND (MatsMh v Record. Mode Code i 11 MatsMh vMeasuredModc/Jst) AND
(MatsMhvRecord.UnadjustcdHourly Value is not null)
if (MonitorHourlyComponentStatus = true) AND (MatsMh v Record. Compo lie lit ID is not null)
if (MatsMhvRecord.PimmcicrCodc is equal to "HGC")
If (MatsMhvRecord. SystemTypeCode is equal to "HG")
Set DailyCalStatusRequired = true.
Set LinearityStatusRequired = true.
If (MatsMh vRecord. H gCo m e rtc rl nd is equal to 1)
Set WsiStatusRequired = true.
else if (MatsMh vRecord. Pa ra 111c tc rCodc is in set {"HCLC", "HFC"})
Set QuarterlyGasAuditStatus = true.
if (MonitorHourlySystemStatus = true) AND (MatsMhvRecord.MonitoringSystcmlD is not null)
Set RataStatusRequired = true.
Environmental Protection Agency
Page 738 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
Usage:
1
2
3
Response
Process/Category:
Process/Category:
Process/Category:
Severity
Emissions Data Evaluation Report MATS HC1 Concentration Monitor Hourly Evaluation
Emissions Data Evaluation Report MATS HF Concentration Monitor Hourly Evaluation
Emissions Data Evaluation Report MATS Hg Concentration Monitor Hourly Evaluation
Environmental Protection Agency
Page 739 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSMHV-14
Check Name: MATS HgC: Complete
Related Former Checks:
Applicability:
Description:
Specifications:
MatsMhvCalculatedHgcValue = MatsMhvCalculatedValue
Results:
Result Response
Usage:
1 Process/Category: Emissions Data Evaluation Report
Severity
MATS Hg Concentration Monitor Hourly Evaluation
Environmental Protection Agency
Page 740 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSMHV-15
Check Name: MATS HC1C: Complete
Related Former Checks:
Applicability:
Description:
Specifications:
MatsMhvCalculatedHclcValue = MatsMhvCalculatedValue
Results:
Result Response
Usage:
1 Process/Category: Emissions Data Evaluation Report
Severity
MATS HC1 Concentration Monitor Hourly Evaluation
Environmental Protection Agency
Page 741 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSMHV-16
Check Name: MATS HFC: Complete
Related Former Checks:
Applicability:
Description:
Specifications:
MatsMhvCalculatedHfcValue = MatsMhvCalculatedValue
Results:
Result Response
Usage:
1 Process/Category: Emissions Data Evaluation Report
Severity
MATS HF Concentration Monitor Hourly Evaluation
Environmental Protection Agency
Page 742 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSMHV-17
Check Name: MATS: QA Status Analyzer Range Parameters
Related Former Checks:
Applicability:
Description:
Specifications:
If (LinearityStatusRequired == true) OR (DailyCalStatusRequired == true)
Set DualRangeStatus = false.
Set ApplicableComponentID = null.
Set ApplicableSystemlDs = null.
Set CurrentAnalyzerRangeUsed = null.
Set HighRangeComponentID = null.
Set LowRangeComponentID = null.
Locate a record in AnalyzerRangeRecordsByHourLocation for the hour and location where the ComponentID is equal to the
QaStatusComponentld.
If (AnalyzerRangeRecordsByHourLocation is not found OR if more than one AnalyzerRangeRecordsByHourLocation is found)
Set LinearityStatusRequired = false
Set DailyCalStatusRequired = false
return result A
Else if (AnalyzerRangeRecordsByHourLocationDualRangelndicator= 1)
Set LinearityStatusRequired = false
Set DailyCalStatusRequired = false
return result B
Else if (AnalyzerRangeRecordsByHourLocation. AnalyzerRangeCode <> "H")
Set LinearityStatusRequired = false
Set DailyCalStatusRequired = false
return result C
Else
Set CurrentAnalyzerRangeUsed = AnalyzerRangeRecordsByHourLocation.AnalyzerRangeCode.
Set ApplicableComponentID = QaStatusComponentld.
Set HighRangeComponentID = QaStatusComponentld.
For each record in MonitorSystemComponentRecordsByHourLocation where the ComponentID is equal to the
ApplicableComponentID
Append MonitorSystemComponentRecordsByHourLocation.SystemlD to ApplicableSystemlDs.
if (MonitorSystemComponentRecordsByHourLocation is not found)
set LinearityStatusRequired = false
set DailyCalStatusRequired = false
Environmental Protection Agency
Page 743 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
return result D
Results:
Result
B
C
D
Response
You did not report one (and only one) valid Analyzer Range record in your monitoring
plan for ComponentID [COMPID] for this hour. The QA Status of the linearity and/or
daily calibration tests for this component will not be evaluated.
You reported that ComponentID [COMPID] is a dual range analyzer, but dual range
analyzers are not allowed for MATS. The QA Status of the linearity and/or daily
calibration tests for this component will not be evaluated.
You reported that ComponentID [COMPID] is not a high range analyzer, but only a
high range analyzer is allowed for MATS. The QA Status of the linearity and/or daily
calibration tests for this component will not be evaluated.
You did not report any System Component records for ComponentID [compid] in your
monitoring plan for the hour. The QA Status of the linearity and/or daily calibration
tests for this component will not be evaluated.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS HC1 Concentration Monitor Hourly Evaluation
2 Process/Category: Emissions Data Evaluation Report MATS HF Concentration Monitor Hourly Evaluation
3 Process/Category: Emissions Data Evaluation Report MATS Hg Concentration Monitor Hourly Evaluation
Environmental Protection Agency
Page 744 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Category:
MATS Operating Hour Checks
Environmental Protection Agency
Page 745 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSHOD-1
Check Name: MATS Hg: Locate Active Monitor Method
Related Former Checks:
Applicability:
Description:
Specifications:
Set MatsHgMethodRecord to null.
Set MatsHgParameterCode to null.
If DerivedHourlyChecksNeeded is equal to true,
Locate MonitorMethodRecordsByHourLocation records where ParameterCode is equal to "HGRE" or "HGRH".
If more than one record was located,
return result A
Else if one record was located,
Set MatsHgMethodRecord to the located record.
Set MatsHgParameterCode to MatsHgMethodRecord.ParameterCode.
Results:
Result Response
A You reported more than one monitoring method record for [param] for the hour and
location.
Usage:
1 Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Severity
Critical Error Level 1
Environmental Protection Agency
Page 746 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSHOD-2
Check Name: MATS HC1: Locate Active Monitor Method
Related Former Checks:
Applicability:
Description:
Specifications:
Set MatsHclMethodRecord to null.
Set MatsHclParameterCode to null.
If DerivedHourlyChecksNeeded is equal to true,
Locate MonitorMethodRecordsByHourLocation records where ParameterCode is equal to "HCLRE" or "HCLRH".
If more than one record was located,
return result A
Else if one record was located,
Set MatsHclMethodRecord to the located record.
Set MatsHclParameterCode to MatsHclMeth od Record. P a ra 1 lie t e rC o de.
Results:
Result Response Severity
A You reported more than one monitoring method record for [param] for the hour and Critical Error Level 1
location.
Usage:
1 Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Environmental Protection Agency
Page 747 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSHOD-3
Check Name: MATS HF: Locate Active Monitor Method
Related Former Checks:
Applicability:
Description:
Specifications:
Set MatsHfMethodRecord to null.
Set MatsHfParameterCode to null.
If DerivedHourlyChecksNeeded is equal to true,
Locate MonitorMethodRecordsByHourLocation records where ParameterCode is equal to "HFRE" or "HFRH".
If more than one record was located,
return result A
Else if one record was located,
Set MatsHfMethodRecord to the located record.
Set MatsHfParameterCode to MatsHfMethodRecord.ParameterCode.
Results:
Result Response
A You reported more than one monitoring method record for [param] for the hour and
location.
Usage:
1 Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Severity
Critical Error Level 1
Environmental Protection Agency
Page 748 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSHOD-4
Check Name: MATS S02: Locate Active Monitor Method
Related Former Checks:
Applicability:
Description:
Specifications:
Set MatsSo2 Met It otlRecord to null.
Set MatsSo2 ParameterCode to null.
If DerivedHourlyChecksNeeded is equal to true,
Locate MonitorMethodRecordsByHourLocation records where ParameterCode is equal to "S02RE" or "S02RH".
If more than one record was located,
return result A
Else if one record was located,
Set MatsSo2MethodRecord to the located record.
Set MatsSo2 ParameterCode to MatsSo2MethodRecord.PiumnclcrCodc.
Results:
Result Response Severity
A You reported more than one monitoring method record for [param] for the hour and Critical Error Level 1
location.
Usage:
1 Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Environmental Protection Agency
Page 749 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSHOD-5
Check Name: MATS: Set MATS Expected Flag
Related Former Checks:
Applicability:
Description:
Specifications:
If MatsHgParameterCode, MatsHclParameterCode, MatsHfParameterCode or MatsSo2 ParameterCode is not null,
Set MatsExpected to true.
Else
Set MatsExpected to false.
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Environmental Protection Agency
Page 750 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSHOD-6
Check Name: MATS Hg: Locate Derived Hourly Record
Related Former Checks:
Applicability:
Description:
Specifications:
Set MatsHgreDhvChecksNeeded to false.
Set MatsHgrhDhvChecksNeeded to false.
Set MatsHgcNeeded to false.
Set MatsHgDhvRecord to null.
Set MatsHgDhvParameterDescription to "MATS Hg Rate".
If DerivedHourlyChecksNeeded is equal to true,
Set RecordCount equal to the number of records in MatsDhvRecordsByHourLocation where ParameterCode is equal to "HGRE"
or "HGRH".
If CurrentHourlyOpRecord.Opc rat i ngTi me is greater than 0
If MatsHgParameterCode is null, and RecordCount is greater than 0,
return result A.
Else if RecordCount is greater than 1,
return result B.
Else if RecordCount is equal to 1,
Set MatsHgDhvRecord to the located MatsDhvRecordsByHourLocation record.
If MatsHgDhvRecord.FammsterCode is equal to MatsHgParameterCode
Set MatsHgcNeeded to true.
if MatsHgDhvRecord.ParameterCode is equal to 'HGRE',
Set MatsHgreDhvChecksNeeded to true,
if MatsHgDhvRecord.ParameterCode is equal to 'HGRH',
Set MatsHgrhDhvChecksNeeded to true.
Else /* DHV and Method parameter code mismatch */
return result C.
Else /* Non Operating Hour */
If RecordCount is greater than 0,
return result D.
Environmental Protection Agency
Page 751 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result Response Severity
A MATS Derived Hourly Value records were reported for [param], but no supporting Critical Error Level 1
method exists.
B You reported more than one MATS Derived Hourly Value records for [param] for the Critical Error Level 1
hour.
C MATS Derived Hourly Value records were reported for [param], but no supporting Critical Error Level 1
method exists.
D You reported MATS Derived Hourly Value records for [param] that are not reported if Critical Error Level 1
the unit did not operate in the hour.
Usage:
1 Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Environmental Protection Agency
Page 752 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSHOD-7
Check Name:
MATS HC1: Locate Derived Hourly Record
Related Former Checks:
Applicability:
Description:
Specifications:
Set MatsHclreDhvChecksNeeded to false.
Set MatsHclrhDhvChecksNeeded to false.
Set MatsHclcNeeded to false.
Set MatsHclDhvRecord to null.
Set MatsHclDhvParameterDescription to "MATS HC1 Rate".
If DerivedHourlyChecksNeeded is equal to true,
Set RecordCount equal to the number of records in MatsDhvRecordsByHourLocation where ParameterCode is equal to "HCLRE"
or "HCLRH".
If CurrentHourlyOpRecord.Ope rat i ngTi me is greater than 0
If HIat.s Hcl Para meter Code is null, and RecordCount is greater than 0,
return result A.
Else if RecordCount is greater than 1,
return result B.
Else if RecordCount is equal to 1,
Set MatsHclDhvRecord to the located MatsDhvRecordsByHourLocation record.
If MatsHclDhvRecord.ParameterCode is equal to Mats Hcl Par a meter Code
Set MatsHclcNeeded to true.
if MatsHclDhvRecord.ParameterCode is equal to 'HCLRE',
Set MatsHclreDhvChecksNeeded to true,
if MatsHclDhvRecord.ParameterCode is equal to 'HCLRH',
Set MatsHclrhDhvChecksNeeded to true.
Else /* DHV and Method parameter code mismatch */
return result C.
Else /* Non Operating Hour */
If RecordCount is greater than 0,
return result D.
Environmental Protection Agency
Page 753 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result Response Severity
A MATS Derived Hourly Value records were reported for [param], but no supporting Critical Error Level 1
method exists.
B You reported more than one MATS Derived Hourly Value records for [param] for the Critical Error Level 1
hour.
C MATS Derived Hourly Value records were reported for [param], but no supporting Critical Error Level 1
method exists.
D You reported MATS Derived Hourly Value records for [param] that are not reported if Critical Error Level 1
the unit did not operate in the hour.
Usage:
1 Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Environmental Protection Agency
Page 754 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSHOD-8
Check Name: MATS HF: Locate Derived Hourly Record
Related Former Checks:
Applicability:
Description:
Specifications:
Set MatsHfreDhvChecksNeeded to false.
Set MatsHfrhDhvChecksNeeded to false.
Set MatsHfcNeeded to false.
Set MatsHfDhvRecord to null.
Set MatsHfDhvParameterDescription to "MATS HF Rate".
If DerivedHourlyChecksNeeded is equal to true,
Set RecordCount equal to the number of records in MatsDhvRecordsByHourLocation where ParameterCode is equal to "HFRE"
or "HFRH".
If CurrentHourlyOpRecord.OpemtingTims is greater than 0
If MatsHf ParameterCode is null, and RecordCount is greater than 0,
return result A.
Else if RecordCount is greater than 1,
return result B.
Else if RecordCount is equal to 1,
Set MatsHfDhvRecord to the located MatsDhvRecordsByHourLocation record.
If MatsHfDhvRecord. ParameterCode is equal to MatsHf ParameterCode
Set MatsHfcNeeded to true.
if MatsHfDhvRecord.ParameterCode is equal to 'HFRE',
Set MatsHfreDhvChecksNeeded to true,
if MatsHfDh vRecord. Para llieterCode is equal to 'HFRH',
Set MatsHfrhDhvChecksNeeded to true.
Else /* DHV and Method parameter code mismatch */
return result C.
Else /* Non Operating Hour */
If RecordCount is greater than 0,
return result D.
Environmental Protection Agency
Page 755 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result Response Severity
A MATS Derived Hourly Value records were reported for [param], but no supporting Critical Error Level 1
method exists.
B You reported more than one MATS Derived Hourly Value records for [param] for the Critical Error Level 1
hour.
C MATS Derived Hourly Value records were reported for [param], but no supporting Critical Error Level 1
method exists.
D You reported MATS Derived Hourly Value records for [param] that are not reported if Critical Error Level 1
the unit did not operate in the hour.
Usage:
1 Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Environmental Protection Agency
Page 756 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSHOD-9
Check Name:
MATS S02: Locate Derived Hourly Record
Related Former Checks:
Applicability:
Description:
Specifications:
Set MatsSo2reDhvChecksNeeded to false.
Set MatsSo2rhDhvChecksNeeded to false.
Set MatsSo2cNeeded to false.
Set MatsSo2DhvRecord to null.
Set MatsSo2DhvParameterDescription to "MATS S02 Rate".
If DerivedHourlyChecksNeeded is equal to true,
Set RecordCount equal to the number of records in MatsDhvRecordsByHourLocation where ParameterCode is equal to "S02RE"
or "S02RH".
If CurrentHourlyOpRecord.Opc rat i ngTi me is greater than 0
If MatsSo2 Parameter Code is null, and RecordCount is greater than 0,
return result A.
Else if RecordCount is greater than 1,
return result B.
Else if RecordCount is equal to 1,
Set MatsSo2DhvRecord to the located MatsDhvRecordsByHourLocation record.
If MatsSo2DhvRecord.FammsterCode is equal to MatsSo2ParameterCode
Set MatsSo2cNeeded to true.
if MatsSo2DhvRecord.ParameterCode is equal to 'S02RE',
Set MatsSo2reDhvChecksNeeded to true,
if MatsSo2 DhvRecord.PimunclcrCodc is equal to 'S02RH',
Set MatsSo2rhDhvChecksNeeded to true.
Else /* DHV and Method parameter code mismatch */
return result C.
Else /* Non Operating Hour */
If RecordCount is greater than 0,
return result D.
Environmental Protection Agency
Page 757 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result Response Severity
A MATS Derived Hourly Value records were reported for [param], but no supporting Critical Error Level 1
method exists.
B You reported more than one MATS Derived Hourly Value records for [param] for the Critical Error Level 1
hour.
C MATS Derived Hourly Value records were reported for [param], but no supporting Critical Error Level 1
method exists.
D You reported MATS Derived Hourly Value records for [param] that are not reported if Critical Error Level 1
the unit did not operate in the hour.
Usage:
1 Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Environmental Protection Agency
Page 758 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSHOD-10
Check Name:
MATS Hg: Locate Monitor Hourly Record
Related Former Checks:
Applicability:
Description:
Specifications:
Set MatsHgcMhvChecksNeeded to false.
Set MatsHgcMh vRecord to null.
If DerivedHourlyChecksNeeded is equal to true,
Set RecordCount equal to the number of records in MatsMhvHgcRecordsByHourLocation.
If CurrentHourlyOpRecord.Opc rat i ngTi me is greater than 0
Else if RecordCount is equal to 0,
return result B.
Else if RecordCount is greater than 1,
return result C.
Else /* RecordCount is equal to 1 */
Set MatsHgcMh v Record to the located MatsMhvHgcRecordsByHour Location record.
Set MatsHgcMhvChecksNeeded to true.
Else /* Non Operating Hour */
If RecordCount is greater than 0,
return result D.
If MatsHgcNeeded is equal to false,
If RecordCount is greater than 0,
return result A.
Results:
Result
A
Response
You reported a MATS Monitor Hourly Value for [param], but did not report either a
MATS Derived Hourly Value or monitoring method for that pollutant.
You did not report a MATS Hourly Monitor Value record for [param], though reporting
a MATS Derived Hourly Value for the hour.
You reported more than one [param] MATS Monitor Hourly Value for the hour.
You reported a MATS Hourly Monitor Value record for [param] for a non-operating
hour.
Severity
Critical Error Level 1
B
Critical Error Level 1
C
D
Critical Error Level 1
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Environmental Protection Agency
Page 759 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSHOD-11
Check Name:
MATS HC1: Locate Monitor Hourly Record
Related Former Checks:
Applicability:
Description:
Specifications:
Set MatsHclcMhvChecksNeeded to false.
Set MatsHclcMh vRecord to null.
If DerivedHourlyChecksNeeded is equal to true,
Set RecordCount equal to the number of records in MatsMhvHclcRecordsByHourLocation.
If CurrentHourlyOpRecord.OpemtingTims is greater than 0
Else if RecordCount is equal to 0,
return result B.
Else if RecordCount is greater than 1,
return result C.
Else /* RecordCount is equal to 1 */
Set MatsHclcMh vRecord to the located MatsMhvHclcRecordsByHourLocation record.
Set MatsHclcMhvChecksNeeded to true.
Else /* Non Operating Hour */
If RecordCount is greater than 0,
return result D.
If MatsHclcNeeded is equal to false,
If RecordCount is greater than 0,
return result A.
Results:
Result
A
Response
You reported a MATS Monitor Hourly Value for [param], but did not report either a
MATS Derived Hourly Value or monitoring method for that pollutant.
You did not report a MATS Hourly Monitor Value record for [param], though reporting
a MATS Derived Hourly Value for the hour.
You reported more than one [param] MATS Monitor Hourly Value for the hour.
You reported a MATS Hourly Monitor Value record for [param] for a non-operating
hour.
Severity
Critical Error Level 1
B
Critical Error Level 1
C
D
Critical Error Level 1
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Environmental Protection Agency
Page 760 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSHOD-12
Check Name:
MATS HF: Locate Monitor Hourly Record
Related Former Checks:
Applicability:
Description:
Specifications:
Set MatsHfcMhvChecksNeeded to false.
Set MatsHfcMh vRecord to null.
If DerivedHourlyChecksNeeded is equal to true,
Set RecordCount equal to the number of records in MatsMhvHfcRecordsByHourLocation where ParameterCode is equal to
Else if RecordCount is equal to 0,
return result B.
Else if RecordCount is greater than 1,
return result C.
Else /* RecordCount is equal to 1 */
Set MatsHfcMh vRecord to the located MatsMhvHfcRecordsByHourLocation record.
Set MatsHfcMhvChecksNeeded to true.
Else /* Non Operating Hour */
If RecordCount is greater than 0,
return result D.
'HFC".
If CurrentHourlyOpRecord.OpemtingTime is greater than 0
If MatsHfcNeeded is equal to false,
If RecordCount is greater than 0,
return result A.
Results:
Result
A
Response
You reported a MATS Monitor Hourly Value for [param], but did not report either a
MATS Derived Hourly Value or monitoring method for that pollutant.
You did not report a MATS Hourly Monitor Value record for [param], though reporting
a MATS Derived Hourly Value for the hour.
You reported more than one [param] MATS Monitor Hourly Value for the hour.
You reported a MATS Hourly Monitor Value record for [param] for a non-operating
hour.
Severity
Critical Error Level 1
B
Critical Error Level 1
C
D
Critical Error Level 1
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Environmental Protection Agency
Page 761 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSHOD-13
Check Name:
MATS: Check MATS Load
Related Former Checks:
Applicability:
Description:
Specifications:
If CurrentHourlyOpRecord is not null
If CurrentHourlyOpRecord.OperatingTime is greater than 0,
If MatsHgParameterCode is equal to "HGRE", OR MatsHclParameterCode is equal to "HCLRE", OR
MatsHfParameterCode is equal to "HFRE", OR MatsSo2ParameterCode is equal to "S02RE",
If CurrentHourlyOpRecord.MatsRourLoad is null,
return result A.
Else
If CurrentHourlyOpRecord.MatsHowLoad is not null,
return result B.
Else
If CurrentHourlyOpRecord.MatsRourLoad is not null,
return result C.
Results:
Result
A
Response
You did not provide a MATSHourLoad record, which is required when you report an
output based emission rate.
You provided a MATSHourLoad record which is not required when you report a heat
input based emission rate.
You reported a MATSHourLoad record, but this is not appropriate for a non-operating
hour.
Severity
Critical Error Level 1
B
Informational Message
C
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Environmental Protection Agency
Page 762 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSHOD-14
Check Name:
Update Sorbent Trap Operating Date List
Related Former Checks:
Applicability:
Description:
Specifications:
If CurrentHourlyOpRecord is NOT null,
For each entry in MatsSorbentTrapListByLocationArray where the array index is CurrentMonitorPlanLocationPosition,
When:
1) CurrentHourlyOpRecord.OperatingTime is greater than 0.
2) CurrentOperatingDate is on or after the date of the entry's SorbentTrapBeginDatehour.
3) CurrentOperatingDate is on or before the date of the entry's SorbentTrapEndDatehour.
4) CurrentOperatingDate is not in the entry's OperatingDateList.
Then:
Append CurrentOperatingDate to the entry's OperatingDateList.
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Operating Hour Evaluation
Environmental Protection Agency
Page 763 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSHOD-15
Check Name:
Initialize Message Plug-ins
Related Former Checks:
Applicability:
Description:
Specifications:
Set MatsHclDhvParameterDescription to "HCLRE or HCLRH".
Set MatsHclMhv Parameter Description to "HCLC".
Set MatsHfDhvParameterDescription to "HFRE or HFRH".
Set MatsHfMhvParameterDescription to "HFC".
Set MatsHgDhvParameterDescription to "HGRE or HGRH".
Set MatsHgMhvParameterDescription to "HGC".
Set MatsSo2DhvParameterDescription to "S02RE or S02RH".
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Summary Value Initialization
Environmental Protection Agency
Page 764 of 850
-------
Draft ECMPS Emissions Check Specifications
Check Category:
MATS Sampling Train Checks
6/17/2015 12:00:00AM
Environmental Protection Agency
Page 765 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSTRN-1
Check Name:
Component ID Valid
Related Former Checks:
Applicability:
Description:
Specifications:
Set MatsSamplingTrainComponentldValid equal to false.
If MatsSamplingTrainRecord. Co mpo ncnt ID is null,
Set MatsSamplingTrainProblemComponentExists equal to true.
Return result A.
Else if MatsSamplingTrainRecord.ComponenfTypeCode is not equal to "STRAIN",
Set MatsSamplingTrainProblemComponentExists equal to true.
Return result B.
Set MatsSamplingTrainComponentldValid equal to true.
Add an entry to MatsSamplingTrainDictionary with a key equal to MatsSampling Train Record. T ra i n ID and the value record
initialized with the following values:
1) Set HgConcentration equal to null
2) Set TrainQAStatusCode equal to null
3) Set ReferenceSFSRRatio equal to null
4) Set TotalSFSRRatioCount equal to 0
5) Set DeviatedSFSRRationCount equal to 0
6) Set SamplingTrainValid equal to true
Add the same entry to MatsSorbentTrapSamplingTrainList.
Else
Results:
Result
A
B
Response
For [key], you have not reported a value for [fieldname], which is required.
The [fieldname] in the monitoring plan is [component type]. A [component type]
[fieldname] is not associated with sorbent trap data.
Severity
Critical Error Level 1
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS Sampling Train Evaluation
Environmental Protection Agency
Page 766 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSTRN-2
Check Name: Sorbent Trap Serial Number
Related Former Checks:
Applicability:
Description:
Specifications:
If the MatsSampling Train Record. S o rb c n t T ra p S n is null,
Return result A.
Results:
Result Response Severity
A You did not provide a [fieldname], which is required, for [key]. Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS Sampling Train Evaluation
Environmental Protection Agency
Page 767 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSTRN-3
Check Name:
Train Quality Assurance Status Valid
Related Former Checks:
Applicability:
Description:
Validation Tables:
Train Qa Status Code (Lookup Table)
Specifications:
Set MatsSamplingTrainQaStatusCodeValid to false.
If MatsSampling Train Record. T ra i 11Q A S t a t u s C ode is null,
If MatsSamplingTrainComponentldValid is true,
Set MatsSampling Train Diction ary. Sam p 1 i ngT ra i n Va 1 i d to false where the key equals
MatsSamplingTrainRecord. T rainID.
Return result A,
Else if MatsSampling Train Record. T ra i nQ A S ta t u s C ode does not match a value in MatsSamplingTrainQaStatusLookupTable,
If MatsSamplingTrainComponentldValid is true,
Set MatsSampling Train Dictionary. Sam pli ngT ra i n Va 1 i d to false where the key equals
MatsSamplingTrainRecord. T rainID.
Set MatsSamplingTrainQaStatusCodeValid to true.
If MatsSamplingTrainComponentldValid is true,
Set MatsSamplingTrain Dictionary."Jxi\mQkS\i\\us,CoA.c to MatsSampling Train Record. T ra i nQ A S t a t u s C ode where the key
equals MatsSamplingTrainRecord. TrainID.
Return result B.
Else
Results:
Result
A
B
Response
For [key], you have not reported a value for [fieldname], which is required.
For [key] you reported a [value] which is not valid for [fieldname].
Severity
Critical Error Level 1
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS Sampling Train Evaluation
Environmental Protection Agency
Page 768 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
Check Name:
Related Former Checks:
Applicability:
Description:
Specifications:
Set MatsMainTrapHgValid to false.
If MatsSamplingTrainQaStatusCodeValid is true,
If the MatsSampling Train Record. IVT a i 11T ra p H g is null,
If the MatsSamplingTrainRecord.QASVdiusCodc is not "INC. ". "EXPIRED", or "LOST",
Return result A.
Otherwise
Set MatsMainTrapHgValid to true.
Else,
If the MatsSamplingTrainRecord.QAStatus Code is not "PASSED", "FAILED", or "UNCERTAIN",
Return result B.
MATSTRN-4
Main Trap Hg Valid
Else, if the MatsSampling Train Record. IVT a i 11T ra p H g is not reported in scientific notation rounded to three decimal
places, keeping one to the left of the decimal point (x.xx-E-x),
Return result C.
Otherwise
Set MatsMainTrapHgValid to true.
Results:
Result
A
B
C
Response
You did not report a [fieldname] value in the [key] records which is required if the
sorbent train QA Status Code is PASSED, FAILED, or UNCERTAIN, and the stack
flow rate for the hour is a measured data value.
You reported a [fieldname] value in the [key] records which is reported only if the
sorbent train QA Status Code is PASSED, FAILED, or UNCERTAIN, and the stack
flow rate for the hour is a measured data value.
The [fieldname] value in the [key] records is not reported in scientific notation rounded
to three significant figures, with one digit to the left of the decimal point.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1
Process/Category: Emissions Data Evaluation Report ¦
¦ MATS Sampling Train Evaluation
Environmental Protection Agency
Page 769 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
Check Name:
Related Former Checks:
Applicability:
Description:
Specifications:
Set MatsBtTrapHgValid to false.
If MatsSamplingTrainQaStatusCodeValid is true,
If the MatsSamplingTr ain Record. BTTrapHg is null,
If the MatsSamplingTrainRecord.QASVdiusCodc is not "INC. ". "EXPIRED", or "LOST",
Return result A.
Otherwise
Set MatsBtTrapHgValid to true.
Else,
If the MatsSamplingTrainRecord.QAStatus Code is not "PASSED", "FAILED", or "UNCERTAIN",
Return result B.
MATSTRN-5
BT Trap Hg Valid
Else if the MatsSamplingTr ain Record. BTT rapHg is not reported in scientific notation rounded to three decimal places,
keeping one to the left of the decimal point (x.xx-E-x),
Return result C.
Otherwise
Set MatsBtTrapHgValid to true.
Results:
Result
A
B
C
Response
You did not report a [fieldname] value in the [key] records which is required if the
sorbent train QA Status Code is PASSED, FAILED, or UNCERTAIN, and the stack
flow rate for the hour is a measured data value.
You reported a [fieldname] value in the [key] records which is reported only if the
sorbent train QA Status Code is PASSED, FAILED, or UNCERTAIN, and the stack
flow rate for the hour is a measured data value.
The [fieldname] value in the [key] records is not reported in scientific notation rounded
to three significant figures, with one digit to the left of the decimal point.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1
Process/Category: Emissions Data Evaluation Report ¦
¦ MATS Sampling Train Evaluation
Environmental Protection Agency
Page 770 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSTRN-6
Check N ame: Spike T rap Hg Valid
Related Former Checks:
Applicability:
Description:
Specifications:
Set MatsSpikeTrapHgValid to false.
If MatsSamplingTrainQaStatusCodeValid is true,
If the MatsSamplingTrain Record. SpikcTrapHg is null,
If the MatsSampling Train Record. Q A S ta t u s C ode is not "INC", "EXPIRED", or "LOST",
Return result A.
Otherwise
Set MatsSpikeTrapHgValid to true.
Else,
If the MatsSamplingTrainRecord.QAStatus Code is not "PASSED", "FAILED", or "UNCERTAIN",
Return result B.
Else if the MatsSamplingTrain Record. SpikcT rapHg is not reported in scientific notation rounded to three decimal
places, keeping one to the left of the decimal point (x.xx-E-x),
Return result C.
Otherwise
Set MatsSpikeTrapHgValid to true.
Results:
Result
B
C
Usage:
1
Response
You did not report a [fieldname] value in the [key] records which is required if the
sorbent train QA Status Code is PASSED, FAILED, or UNCERTAIN, and the stack
flow rate for the hour is a measured data value.
You reported a [fieldname] value in the [key] records which is reported only if the
sorbent train QA Status Code is PASSED, FAILED, or UNCERTAIN, and the stack
flow rate for the hour is a measured data value.
The [fieldname] value in the [key] records is not reported in scientific notation rounded
to three significant figures, with one digit to the left of the decimal point.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Process/Category: Emissions Data Evaluation Report ¦
¦ MATS Sampling Train Evaluation
Environmental Protection Agency
Page 771 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
Check Name:
Related Former Checks:
Applicability:
Description:
Specifications:
Set MatsSpikeReferenceValueValid to false.
If MatsSamplingTrainQaStatusCodeValid is true,
If the MatsSamplingTrainRecord.SpikeReferenceValue is null,
If the Sampling Train Data.Q ASt a t u s C ode is not "INC", "EXPIRED", or "LOST",
Return result A.
Otherwise
Set MatsSpikeReferenceValueValid to true.
Else,
If the MatsSamplingTrainRecord.QAStatus Code is not "PASSED", "FAILED", or "UNCERTAIN",
Return result B.
MATSTRN-7
Spike Reference Value Valid
Else if the MatsSumpling Train Record. S p ike Re fc re nee Va 1 lie is not reported in scientific notation rounded to three
decimal places, keeping one to the left of the decimal point (x.xx-E-x),
Return result C.
Otherwise
Set MatsSpikeReferenceValueValid to true.
Results:
Result
A
B
C
Response
You did not report a [fieldname] value in the [key] records which is required if the
sorbent train QA Status Code is PASSED, FAILED, or UNCERTAIN, and the stack
flow rate for the hour is a measured data value.
You reported a [fieldname] value in the [key] records which is reported only if the
sorbent train QA Status Code is PASSED, FAILED, or UNCERTAIN, and the stack
flow rate for the hour is a measured data value.
The [fieldname] value in the [key] records is not reported in scientific notation rounded
to three significant figures, with one digit to the left of the decimal point.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1
Process/Category: Emissions Data Evaluation Report ¦
¦ MATS Sampling Train Evaluation
Environmental Protection Agency
Page 772 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSTRN-8
Check Name:
Total Sample Volume DSCM Valid
Related Former Checks:
Applicability:
Description:
Specifications:
Set MatsTotalSampleVolumeDSCMValid to false.
If MatsSamplingTrainQaStatusCodeValid is true,
If the MatsSampling Train Record. To ta 1S a m p 1 c Vo 1 u mc D S CIVI is null,
If the Sampling Train Data.QASi a t u s C ode is not "INC", "EXPIRED", or "LOST",
If the MatsSamplingTrainRecord.QAStatus Code is not "PASSED", "FAILED", or "UNCERTAIN",
Return result B.
Else if the MatsSampling Train Record. To ta 1S a m p 1 c Vo 1 u mc D S C IVI is not reported to two decimal places ,
Return result C.
Otherwise
Set Mats TotalSample VolumeDSCM V(did to true.
Return result A.
Otherwise
Set Mats TotalSample VolumeDSCM Valid to true.
Else,
Results:
Result
A
Response
You did not report a [fieldname] value in the [key] records which is required if the
sorbent train QA Status Code is PASSED, FAILED, or UNCERTAIN, and the stack
flow rate for the hour is a measured data value.
You reported a [fieldname] value in the [key] records which is reported only if the
sorbent train QA Status Code is PASSED, FAILED, or UNCERTAIN, and the stack
flow rate for the hour is a measured data value.
For [key], the [fieldname] value is not reported to two decimal places.
Severity
Critical Error Level 1
B
Critical Error Level 1
C
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS Sampling Train Evaluation
Environmental Protection Agency
Page 773 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSTRN-9
Check Name:
Related Former Checks:
Reference SFSR Ratio Valid
Applicability:
Description:
Specifications:
If MatsSamplingTrainQaStatusCodeValid is true,
If the MatsSamplingTrainRcfcrcnccSFSRRatio is null,
If the MatsSampling Train Record. Q A S ta t u s C ode is not "INC", "EXPIRED", or "LOST",
If MatsSamplingTrainComponentldValid is true,
Set MatsSamplingTrainDictionary. SamplingTrainValid to false where the key equals
MatsSamplingTrainRecord. T rainID.
Return result A.
Else,
If the MatsSamplingTrainRecord.QAStatas Code is not "PASSED", "FAILED", or "UNCERTAIN",
If MatsSamplingTrainComponentldValid is true,
Set MatsSamplingTrainDictionary. SamplingTrainValid to false where the key equals
MatsSamplingTrainRecord. T rainID.
Return result B.
Else if the MatsSampling Train Record. Rc fc rc ncc S F S R Ra t i o is not reported to one decimal place,
If MatsSamplingTrainComponentldValid is true,
Set MatsSamplingTrainDictionary.SampYmgY rain Valid to false where the key equals
MatsSamplingTrainRecord. T rainID.
Return result C.
Else if the MatsHourlyGFMRecord.Hourly SFSRRatio is not greater than or equal to 1.0 and less than or equal to 100.0,
If MatsSamplingTrainComponentldValid is true,
Set MatsSamplingTrainDictionary. SamplingTrainValid to false where the key equals
MatsSamplingTrainRecord. T rainID.
Return result D.
Else
If MatsSamplingTrainComponentldValid is true,
Set MatsSamplingTrainDictionary.ReferenceSFSRRatio to
MatsSampling Train Record. Rc fc rc ncc S F S R Ra t i o where the key equals
MatsSamplingTrainRecord. T rainID.
Environmental Protection Agency
Page 774 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
B
C
D
Usage:
1
Response
You did not report a [fieldname] value in the [key] records which is required if the
sorbent train QA Status Code is PASSED, FAILED, or UNCERTAIN, and the stack
flow rate for the hour is a measured data value.
You reported a [fieldname] value in the [key] records which is reported only if the
sorbent train QA Status Code is PASSED, FAILED, or UNCERTAIN, and the stack
flow rate for the hour is a measured data value.
The [fieldname] value for [key] should be reported to one decimal place.
The [fieldname] value for [key] must be a number between 1 and 100.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Process/Category: Emissions Data Evaluation Report ¦
¦ MATS Sampling Train Evaluation
Environmental Protection Agency
Page 775 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSTRN-10
Check Name: Sampling Ratio Check Result Code Valid
Related Former Checks:
Applicability:
Description:
Specifications:
If MatsSamplingTrainQaStatusCodeValid is true,
If MatsSamplingTrainRecord.SamplingRatioChsckResultCode is null,
If the MatsSampling Train Record. Q A S ta t u s C ode is not "INC", "EXPIRED", or "LOST",
If MatsSamplingTrainComponentldValid is true,
Set MatsSamplingTrainDictionary.SamplingTrainValid to false where the key equals
MatsSamplingTrainRecord. T rainID.
Return result A.
Else,
If MatsSamplingTrainRecord.SamplingRatioCheckResultCode is equal to "PASSED",
If MatsSamplingTrainRecord.QAStatus Code is not equal "PASSED", "FAILED", or "UNCERTAIN",
If MatsSamplingTrainComponentldValid is true,
Set MatsSamplingTrainDictionary.SamplingTrainValid to false where the key equals
MatsSamplingTrainRecord. T rainID.
Return result B.
Else if MatsSamplingTrainRecord.Si\mp\ingR'MioC\\cckRcsu\lCodc is equal to "FAILED",
If MatsSampling Train Record. Q A S ta t u s Code is not equal "FAILED",
If MatsSamplingTrainComponentldValid is true,
Set MatsSamplingTrainDictionary.SamplingTramValid to false where the key equals
MatsSamplingTrainRecord. T rainID.
Return result C.
Otherwise
If MatsSamplingTrainComponentldValid is true,
Set MatsSamplingTrainDictionary.SampYmgY rain Valid to false where the key equals
MatsSamplingTrainRecord. T rainID.
Return result D.
Environmental Protection Agency
Page 776 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
B
C
D
Usage:
1
Response
You did not report a [fieldname] value in the [key] records which is required if the
sorbent train QA Status Code is PASSED, FAILED, or UNCERTAIN, and the stack
flow rate for the hour is a measured data value.
You reported a [fieldname] value in the [key] records which is reported only if the
sorbent train QA Status Code is PASSED, FAILED, or UNCERTAIN, and the stack
flow rate for the hour is a measured data value.
For [key], you reported that the sampling train SFSR Ratio check FAILED, but did not
also report the train QA Status Code as FAILED.
For [key], the [fieldname] is not reported as PASSED or FAILED..
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Process/Category: Emissions Data Evaluation Report MATS Sampling Train Evaluation
Environmental Protection Agency
Page 777 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
Check Name:
Related Former Checks:
Applicability:
Description:
Specifications:
If MatsSamplingTrainQaStatusCodeValid is true,
If the MatsSamplingTrainRecord.FosiLedkChsckRssultCode is null,
If the MatsSampling Train Record. Q A S ta t u s C ode is not" "INC", "EXPIRED" or "LOST",
Return result A.
Else
If MatsSamplingTrainRecord.PostLeakCheckResultCode is equal to "PASSED",
If MatsSampling Train Record. Q A S t a t u s Code is not equal to "PASSED", "FAILED", OR "UNCERTAIN",
Return result B.
Else if MatsSamplingTrainRecord.PostLeakCheckResultCode is equal to "FAILED",
If MatsSamplingTrainRecord.QAStatus Code is not equal to "FAILED",
Return result C.
Otherwise
Return result D.
MATSTRN-11
Post Leak Check Result Code Valid
Results:
Result
A
B
C
D
Usage:
1
Response
You did not report a [fieldname] value in the [key] records which is required if the
sorbent train QA Status Code is PASSED, FAILED, or UNCERTAIN, and the stack
flow rate for the hour is a measured data value.
You reported a [fieldname] value in the [key] records which is reported only if the
sorbent train QA Status Code is PASSED, FAILED, or UNCERTAIN, and the stack
flow rate for the hour is a measured data value.
The [fieldname] value of [value] from the [key] records exceeds the PS-12B
breakthrough criteria, but you did not report the train QA Status Code as FAILED.
The [fieldname] is not reported as PASSED or FAILED.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Process/Category: Emissions Data Evaluation Report ¦
¦ MATS Sampling Train Evaluation
Environmental Protection Agency
Page 778 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSTRN-12
Check Name:
Sample Damage Explanation
Related Former Checks:
Applicability:
Description:
Specifications:
If MatsSamplingTrainQaStatusCodeValid is true,
If the MatsSampUngTrain Record. Sa mple Da mage Expla nat io n is null,
If the MatsSampling Train Record. Q A S t a t u s Code is equal to "LOST",
Return result A.
Results:
Result
A
Response
For [key], you did not report a SampleDamageExplanation which is required if the
sorbent train QA Status Code is LOST.
Severity
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS Sampling Train Evaluation
Environmental Protection Agency
Page 779 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSTRN-13
Check Name:
Related Former Checks:
Hg Concentration reported properly
Applicability:
Description:
Specifications:
Set MatsCalcTrainHgConcentration = null.
If MatsSamplingTrainQaStatusCodeValid is true,
If MatsSamplingTrain Record.HgConcen\xa\\on is null,
If MatsSamplingTrainRecord JrainQAStatusCode is not "INC", "EXPIRED", or "LOST",
If MatsSamplingTrainComponentldValid is true,
Set MatsSamplingTrainDictionary. SamplingTrainValid to false where the key equals
MatsSamplingTrainRecord. T rainID.
Return result A.
If MatsSamplingTrainRecord.TrainQAStatusCode is not "PASSED", "FAILED", or "UNCERTAIN",
If MatsSamplingTrainComponentldValid is true,
Set MatsSamplingTrainDictionary.SampMngYxainVaWd to false where the key equals
MatsSamplingTrainRecord. T rainID.
Return result B.
Else if MatsSamplingTrainRecord. HgCo ncc ntrat io n is not reported in scientific notation rounded to three decimal
places, keeping one to the left of the decimal point (x.xx-E-x).
If MatsSamplingTrainComponentldValid is true,
Set MatsSamplingTrainDictionary. SamplingTrainValid to false where the key equals
MatsSamplingTrainRecord. T rainID.
Return result C.
Else if Mats Main TrapHg Va lid is true AND MatsB TTrapHg Valid is true AND Mats TotalSample VolumeDSCM Valid is
true,
Set MatsCalcTrainHgConcentration = (MatsSamplingTrainRecord Ma i 11TrapHg +
MatsSampling Train Record. B TTra p H g) / MatsSampling Train Record. To ta 1S a m p 1 c Vo 1 u mc D S CIVI. rounded to
three significant figures, using scientific notation (x.xx-E-2).
If MatsSamplingTrainComponentldValid is true,
Set MatsSamplingTrainDictionary.HgConccnlri\Uon to MatsCalcTrainHgConcentration where the key
cq ua 1 s MatsSampling Train Record. T ra i n ID.
If MatsSamplingTrainRecord.HgConccnlmUon is not equal to MatsCalcTrainHgConcentration,
Else,
If MatsSamplingTrainComponentldValid is true,
Set MatsSamplingTrainDictionary. SamplingTrainValid to false where the key equals
MatsSamplingTrainRecord. T rainID.
Environmental Protection Agency
Page 780 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Return result D
Else // A calculation input is not valid
If MatsSamplingTrainComponentldValid is true,
Set MatsSamplingTrainDictionary.SamplingTrainValid to false where the key equals
MatsSamplingTrainRecord. T rainID.
Results:
Result
A
B
C
D
Response
You did not report a [fieldname] value in the [key] records which is required if the
sorbent train QA Status Code is PASSED, FAILED, or UNCERTAIN, and the stack
flow rate for the hour is a measured data value.
You reported a [fieldname] value in the [key] records which is reported only if the
sorbent train QA Status Code is PASSED, FAILED, or UNCERTAIN, and the stack
flow rate for the hour is a measured data value.
The [fieldname] value in the [key] records is not reported in scientific notation rounded
to three significant figures, with one digit to the left of the decimal point.
The [fieldname] is inconsistent with the value [value] calculated from the reported [key]
records used in the calculation.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1
Process/Category: Emissions Data Evaluation Report ¦
¦ MATS Sampling Train Evaluation
Environmental Protection Agency
Page 781 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSTRN-14
Check Name:
Percent Breakthrough reported properly.
Related Former Checks:
Applicability:
Description:
Specifications:
If MatsSamplingTrainQaStatusCodeValid is true,
If the MatsSampling Train Record. P c rcc n t B rc a k t h ro ug h is null,
If the MatsSamplingTrainRecord.QAStatus Code is "PASSED", "FAILED", or "UNCERTAIN", AND the.
MatsSamplingTrain Record.HgConccntration is greater than or equal to 0.2,
Return result A.
If the MatsSampling Train Record. Q A S t a t u s C ode is "LOST", "EXPIRED", or "INC",
Return result B
Else if the MatsSamplingTrainRecord.PercentBreakthrough is NOT reported to one decimal place.
Return result C
Else if MatsMainTrapHgValid is equal to true, and MatsBtTrapHgValid is equal to true,
Set MatsCalcTrainPercentBreakthrough = (MatsSampling Train Record. B TT ra p H g /
MatsSamplingTrain Record Mi\\nYrapHg) x 100, rounded to one decimal place.
If MatsSamplingTrainRecord.PercentBreakthrough is NOT equal to MatsCalcTrainPercentBreakthrough,
Return result D,
Else, if the MatsSamplingTrain Record. H gCo nccnt rat io n is NOT less than 0.2,
If the MatsSamplingTrainRecord.PercentBreakthrough is greater than 10%, OR
the MatsSamplingTrainRecord.PercentBreakthrough is greater than 5%, AND the
Else,
MatsSamplingTrainRecord.HgConcentration is greater than 0.5,
If MatsSampling Train Record. T ra i nQ A S ta tus Code is NOT equal to "FAILED",
Return result E
Results:
Result
A
Response
For [key], you did not report a [fieldname] value which is required if the sorbent train
QA Status Code is PASSED, FAILED, or UNCERTAIN, and the train Hg
Concentration is not less than 10% of the Hg limit equivalent concentration.
For [key], you reported a [fieldname] value which is not reported if the sorbent train
QA Status Code is LOST, EXPIRED, or INC.
The [fieldname] value for [key] should be reported to one decimal place.
The [fieldname] is inconsistent with the value [value] calculated from the reported [key]
records used in the calculation.
The [fieldname] value of [value] from the [key] records exceeds the PS-12B
breakthrough criteria, but you did not report the train QA Status Code as FAILED.
Severity
Critical Error Level 1
B
Critical Error Level 1
C
D
Critical Error Level 1
Critical Error Level 1
E
Critical Error Level 1
Environmental Protection Agency
Page 782 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS Sampling Train Evaluation
Environmental Protection Agency
Page 783 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSTRN-15
Check Name: Percent Spike Recovery reported properly
Related Former Checks:
Applicability:
Description:
Specifications:
If MatsSamplingTrainQaStatusCodeValid is true,
If the MatsSamplingTrainRecord. PercentSpikeRecovery is null,
If the MatsSamplingTrainRecord.QAStatus Code is not "INC", "EXPIRED", or "LOST",
Return result A.
Else
If the MatsSampling Train Record. Q A S ta t u s Code is not "PASSED", "FAILED", or "UNCERTAIN",
Return result B.
Else if the MatsSampling Train Record. PcrccntSpikcRccovery is not reported to one decimal place,
Return result C.
Else if MatsSpikeTrapHgValid is equal to true, AND MatsSpikeReferenceValueValid, is equal to true,
Set MatsCalcTrainPercentSpikeRecovery = MatsSampling Train Record. S p i k c T ra p H g /
MatsSampling Train Record. S p ike Re fc re nee Va 1 lie) x 100, rounded to one decimal place.
If MatsSampling Train Record. PcrccntSpikcRccovery is not equal to MatsCalcTrainPercentSpikeRecovery,
Return result D.
Else if the MatsSamplingTrainRecord. PcrccnlSplkcRcco\ cr\ is less than 75% or greater than 125%
If MatsSamplingTrainRecord.TrmnQASVMusCodc is not equal to "FAILED",
Return result E
Results:
Result Response
A You did not report a [fieldname] value in the [key] records which is required if the
sorbent train QA Status Code is PASSED, FAILED, or UNCERTAIN, and the stack
flow rate for the hour is a measured data value.
B You reported a [fieldname] value in the [key] records which is reported only if the
sorbent train QA Status Code is PASSED, FAILED, or UNCERTAIN, and the stack
flow rate for the hour is a measured data value.
C The [fieldname] value for [key] should be reported to one decimal place.
D The [fieldname] is inconsistent with the value [value] calculated from the reported [key]
records used in the calculation.
E The [fieldname] value of [value] from the [key] records exceeds the PS-12B
breakthrough criteria, but you did not report the train QA Status Code as FAILED.
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS Sampling Train Evaluation
Seventy
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 784 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSTRN-16
Check Name:
Check Hourly Sampling Ratios
Related Former Checks:
Applicability:
Description:
Specifications:
If MatsSamplingTrain Dictionary contains the key MatsSamplingTrain Record.Trai n ID.
Set SamplingTrainValid to MatsSamplingTrain Dictionary.SnmpMngT rain Valid where the key equals
MatsSampling Train Record. T ra i n ID.
Else
Set SamplingTrainValid to false.
If SamplingTrainValid is true,
Set TotalSFSRRatioCount to MatsSamplingTrain Dictionary.To[c\\SFSRRi\{ioCoun{ where the key equals
MatsSampling Train Record. T ra i n ID.
Set DeviatedSFSRRatioCount to MatsSamplingTrain Dictionary.Dcv'vMcdSFSRRaUoCounl where the key equals
MatsSampl ing Train Record. T ra i n ID.
If TotalSFSRRatioCount is greater than or equal to 100,
Set MatsCalcPercentSFSRRatioDev to DeviatedSFSRRatioCount I TotalSFSRRatioCount x 100, rounded to an integer.
If the MatsSamplingTrain Record.SnmpUngRnUoChcckRcsuhCodc is equal to "PASSED"
If the MatsCalcPercentSFSRRatioDev is greater than 5,
Return result A.
Else if the MatsSamplingTrain Record.SmnpUngRnUoChcckRcsuhCodc is equal to "FAILED",
If the MatsCalcPercentSFSRRatioDev is less than or equal to 5,
Return result B.
Else // TotalSFSRRatioCount is less than 100
If the MatsSamplingTrain Record.SnmpUngRnUoChcckRcsuhCodc is equal to "PASSED"
If the DeviatedSFSRRatioCount is greater than 5,
Return result C.
If the MatsSamplingTrainRecord.SamplingRatioChsckResultCode is equal to "FAILED",
If the DeviatedSFSRRatioCount is less than or equal to 5,
Return result D.
Environmental Protection Agency
Page 785 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
B
C
D
Usage:
1
Response Severity
For [key], you reported that the SFSR Ratio Check PASSED, but more than five Critical Error Level 1
percent of hourly SFSR Ratios deviated from the reference ratio by more than 25
percent.
For [key], you reported that SFSR Ratio Check FAILED, but not more than five percent Critical Error Level 1
of hourly SFSR Ratios deviated from the reference ratio by more than 25 percent.
For [key], you reported that the SFSR Ratio Check PASSED, but more than five hourly
SFSR Ratios deviated from the reference ratio by more than 25 percent.
For [key], you reported that the SFSR Ratio Check FAILED, but not more than five
hourly SFSR Ratios deviated from the reference ratio by more than 25 percent.
Critical Error Level 1
Critical Error Level 1
Process/Category: Emissions Data Evaluation Report MATS Sampling Train Last Hour Evaluation
Environmental Protection Agency
Page 786 of 850
-------
Draft ECMPS Emissions Check Specifications
Check Category:
MATS Sorbent Trap Data
6/17/2015 12:00:00AM
Environmental Protection Agency
Page 787 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSTRP-1
Check Name:
Begin Date Valid
Related Former Checks:
Applicability:
Description:
Specifications:
Set MatsSorbentTrapBeginDateValid equal to false.
If the MatsSorbent TrapRecoril. Bcgi nDa tc is null,
Set MatsSorbentTrapEvaluationNeeded to false.
Return Result A.
Else
Set MatsSorbentTrapBeginDateValid equal to true.
Results:
Result Response Severity
A For [key], a value for [fieldname] is required. Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report — MATS Sorbent Trap Hour and Range Evaluation
Environmental Protection Agency
Page 788 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSTRP-2
Check Name:
Begin Hour Valid
Related Former Checks:
Applicability:
Description:
Specifications:
Set MatsSorbentTrapBeginDateHourValid equal to false.
If MatsSorbentTrapBeginDate Valid,
If the MatsSorbent TrapRecord. Begi nHour is null,
Set MatsSorbentTrapEvaluationNeeded to false.
Return Result A.
Else, if the MatsSorbent TrapRecord. B eg i n H o u r is less than 0 or greater than 23,
Set MatsSorbentTrapEvaluationNeeded to false.
Return Result B.
Else
MatsSorbentTrapBeginDateHourValid equal to true.
Results:
Result
A
B
Response
For [key], a value for [fieldname] is required.
For [key], you have reported a Begin Hour not between 0 and 23.
Severity
Critical Error Level 1
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report — MATS Sorbent Trap Hour and Range Evaluation
Environmental Protection Agency
Page 789 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: MATSTRP-3
Check Name: End Date Valid
Related Former Checks:
Applicability:
Description:
Specifications:
Set MatsSorbentTrapEndDateValid equal to false.
If the MatsSorbentTrapRecord.EndDate is null,
Set MatsSorbentTrapEvaluationNeeded to false.
Return Result A.
Else
Set MatsSorbentTrapEndDateValid equal to true.
Results:
Result Response Severity
A For [key], a value for [fieldname] is required. Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report — MATS Sorbent Trap Hour and Range Evaluation
Environmental Protection Agency
Page 790 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSTRP-4
Check Name:
End Hour Valid
Related Former Checks:
Applicability:
Description:
Specifications:
Set MatsSorbentTrapEndDateHourValid equal to false.
If the MatsSorbentTrapRecord.EndHour is null,
Set MatsSorbentTrapEvaluationNeeded to false.
Return Result A.
Else, if the MatsSorbentTrapRecord.EndHour is less than 0 or greater than 23,
Set MatsSorbentTrapEvaluationNeeded to false.
Return Result B.
Else
Set MatsSorbentTrapEndDateHourValid equal to true.
Results:
Result
A
B
Response
For [key], a value for [fieldname] is required.
For [key], you have reported an End Hour that is not between 0 and 23.
Severity
Critical Error Level 1
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report — MATS Sorbent Trap Hour and Range Evaluation
Environmental Protection Agency
Page 791 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSTRP-5
Check Name:
Begin and End Times Consistent
Related Former Checks:
Applicability:
Description:
Specifications:
Set MatsSorbentTrapDatesAndHoursConsistent to false.
If MatsSorbentTrapBeginDateHourValid is true AND MatsSorbentTrapEndDateHourValid is true,
If the the MatsSorbentTrapRecord. BcginDatcHour is after the MatsSorbentTrapRecord.EndDateHour,
Set MatsSorbentTrapEvaluationNeeded to false.
Return result A.
Else
Set MatsSorbentTrapDatesAndHoursConsistent to true.
Results:
Result
A
Response
For [key], the BeginDate/Hour is inconsistent with the EndDate/Hour.
Severity
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report — MATS Sorbent Trap Hour and Range Evaluation
Environmental Protection Agency
Page 792 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSTRP-6
Check Name:
Check For Overlap With Another Sorbent Trap
Related Former Checks:
Applicability:
Description:
Specifications:
Locate MatsSorbentTrapRecords where:
1) Systemld equalsMatsSorbentTrapRecord.Systemld
2) Trapld does not equal MutsSorbentTrapRecord.Trap Id
3) BeginDateHour is before MatsSorbentTrapRecord.EndDateRow
4) EndDateHour is after MutsSorbentTrapRecord. BeginDateHour
If found,
Set MatsSorbentTrapEvaluationNeeded to false.
Return result A.
Results:
Result
A
Response
For [key], you reported sorbent traps with overlapping sampling periods.
Severity
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS Sorbent Trap Overlap Evaluation
Environmental Protection Agency
Page 793 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
Check Name:
Related Former Checks:
Applicability:
Description:
Specifications:
Set MatsSorbentTrapValidExists to false.
Set MatsSorbentTrapSamplingTrainList to null.
Set MatsSamplingTrainProblemComponentExists to false.
For MatsSorbentTrapRecord:
If MatsSorbentTrapRecordEndDateHour is after CurrentReportingPeriodEndHour,
Set SorbentTrapForQuarterBorder to true.
Else
Set SorbentTrapForQuarterBorder to false.
Set SorbentTrapInformation record with:
1) SorbentTrapValidExists set to true.
2) SorbentTrapForQuarterBorder set to SorbentTrapForQuarterBorder.
3) SorbentTrapId set to MatsSorbentTrapRecord.TrapId
3) SorbentTrapBeginDateHour set to MatsSorbentTrapRecord.BeginDatcHour
4) SorbentTrapEndDateHour set to MatsSorbentTrapRecord.EndDateHour
5) SorventTrapModcCd set to MatsSorbentTrapRecord.ModcCd
6) SamplingTrainProblemComponentExists set to false.
7) SamplingTrainList with a record containing the following fields:
a) HgConcentration as a decimal
b) TrainQAStatusCode as a string
c) ReferenceSFSRRatio as an integer
d) TotalSFSRRatioCount as an integer
e) DeviatedSFSRRatioCount as an integer
f) SamplingTrainValid as a boolean
8) OperatingDateList set to an empty list of dates.
Set MatsSorbentTrapDictionary to SorbentTrapInformation, where the Locationld key is equal MatsSorbentTrapRecord J rapid.
Append SorbentTrapInformation to MatsSorbentTrapListByLocationArray element for CurrentMonitorPlanLocationPosition.
Set MatsSorbentTrapValidExists to MatsSorb en t TrapDiction ary. S o rb c n tT ra p Va 1 i d E \ i s t s where MatsSorbentTrapDictionary key
is equal to MatsSorbentTrapRecord. Trap Id.
Set MatsSorbentTrapSamplingTrainList to MatsSorbentTrapDictionary. SamplingTrainList where MatsSorbentTrapDictionary
key is equal to MatsSorbentTrapRecord J rapid.
Set MatsSamplingTrainProblemComponentExists to MatsSorbentTrapDictionary.SampYmgYrainProblcmComponent Exists
where MatsSorbentTrapDictionary key is equal to MatsSorbentTrapRecord.Trapld.
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS Sorbent Trap First Hour Initialization
MATSTRP-7
Initialize MATS Sorbent Trap Parameters
Environmental Protection Agency
Page 794 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSTRP-8
Check Name:
Monitoring System Check
Related Former Checks:
Applicability:
Description:
Specifications:
If the MatsSorbentTrapRecord. Mo n i to ri ng Sy stc m ID is null,
Set MatsSorbentTrapValidExists to false.
Return result A.
Else, if the MatsSorbentTrapRecord. Sy stc mTy pcCodc of the associated system is not equal to "ST",
Set MatsSorbentTrapValidExists to false.
Return result B.
Results:
Result
A
B
Response
For [key], you have not reported a value for [fieldname], which is required.
The SystemTypeCode in the monitoring plan is [system type]. This type of system
does not report sorbent trap data.
Severity
Critical Error Level 1
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS Sorbent Trap Evaluation
Environmental Protection Agency
Page 795 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSTRP-9
Check Name:
Number and Validity of Sampling Trains
Related Former Checks:
Applicability:
Description:
Specifications:
Set MatsSamplingTrainsValid to false,
If MatsSamplingTrainProblemComponentExists is false,
If number of entries in MatsSorbentTrapSamplingTrainList is not equal to 2,
Set MatsSorbentTrapValidExiststo false.
Return result A.
Else if MatsSorbentTrapSamplingTrainList .SamplingTrainValid for one or both sampling train components is false,
Set MatsSorbentTrapValidExists to false.
Else
Set MatsSamplingTrainsValid to true
Results:
Result
A
Response
For [key], you did not report two sets of sorbent train records for the sorbent trap.
Severity
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS Sorbent Trap Evaluation
Environmental Protection Agency
Page 796 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSTRP-10
Check Name:
Sorbent Trap MODC Code is Valid
Related Former Checks:
Applicability:
Description:
Specifications:
Set MatsSorbentTrapMODCCodeValid to false
If MatsSorbentTrapRecord.MODCCode is not equal to "01", "02", "32", "33", "34" or "35",
Set MatsSorbentTrapValidExists to false.
Return result A.
Else if MatsSamplingTrainsValid,
If MatsSorbentTrapRecord.MODCCode is equal to "01" or "02",
If MatsSorbentTrapSampHngTrainlAst.TraiiiQAStatusCode for both sampling train components are equal to "PASSED",
Set MatsSorbentTrapMODCCodeValid equal to true.
Else
Set MatsSorbentTrapValidExists to false.
Return result B
Else if MatsSorbentTrapRecord.MODCCode is equal to "32",
If MatsSorbentTrapSamplingTrainList.TmmQAStatusCode are equal to "PASSED" for one sampling train component,
AND "FAILED" or "LOST" for the other,
Set MatsSorbentTrapMODCCodeValid equal to true.
Else
Set MatsSorbentTrapValidExists to false.
Return result C
Else if the MatsSorbentTrapRecord.MODCCode is equal to "33",
If MatsSorbentTrapSamplingTrainList.TmmQAStatusCode for both sampling train components are equal to
"UNCERTAIN",
Set MatsSorbentTrapMODCCodeValid equal to true.
Else
Set MatsSorbentTrapValidExists to false.
Return result D
Else if the MatsSorbentTrapRecord.MODCCode is equal to "34",
If MatsSorbentTrapSamplingTrainList.TmmQAStatusCode for both sampling train components are equal to "FAILED",
Set MatsSorbentTrapMODCCodeValid equal to true.
Else If MatsSorbentTrapSamplingTrainList^TraiiiQAStatusCode for both sampling train components are equal to
"UNCERTAIN",
Environmental Protection Agency
Page 797 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Set MatsSorbentTrapMODCCodeValid equal to true.
Else if MatsSorbentTrapSamplingTrainList.TminQAStatusCode for one or both sampling train components is equal to
"LOST", "EXPIRED" or "INC",
Set MatsSorbentTrapMODCCodeValid equal to true.
Else
Set MatsSorbentTrapValidExiststo false.
Return result E
Else if the MatsSorbentTrapRecord.MODCCode is equal to "35',
Set MatsSorbentTrapMODCCodeValid equal to true.
Results:
Result Response
A For [key] you reported a [value] which is not valid for [fieldname].
B For [key], you reported a [fieldname] cf [value] which is valid if the QA Status Codes
of both trains is PASSED.
C For [key], you reported a [fieldname] cf [value] which is valid if the QA Status Code
of one train is PASSED and the other FAILED.
D For [key] you reported a [fieldname] cf [value] which is valid if the QA Status Code of
both trains is UNCERTAIN.
E For [key], you reported a [fieldname] cf [value] which is valid if the QA Status Code of
both trains is FAILED or UNCERTAIN, or one or both trains is LOST, EXPIRED, or
INC.
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS Sorbent Trap Evaluation
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 798 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSTRP-11
Check Name:
Related Former Checks:
Paired Trap Agreement Validation and Re-calculation
Applicability:
Description:
Specifications:
Set MatsSorbentTrapPairedTrapAgreementValid to false.
Set MatsCalcTrapAbsoluteDifference = null.
Set MatsCalcTrapPercentDifference = null.
If the MatsSorbentTrapMODCCodeValid is equal to true,
If MatsSorbentTrapRecord.PmkAJrapAgrccmerit is null,
If MatsSorbentTrapRecord MODCCodc is not "32". "34", or "35',
Set MatsSorbentTrapValidExiststo false.
Return result A.
Else if MatsSorbentTrapRecord. AbsoluteDifferencelndicator is not null,
Set MatsSorbentTrapValidExists to false.
Return result B.
If MatsSorbentTrapRecordMODCCode is not "01", "02", or "33",
Set MatsSorbentTrapValidExists to false.
Return result C.
Else if MatsSorbentTrapRecord.PmrcdT rap Agreement is not rounded to two decimal places)
Set MatsSorbentTrapValidExists to false.
Return result D.
Else if MatsSorbentTrapRecord. AbsoluteDifferencelndicator is equal to 0, OR
MatsSorbentTrapRecord. AbsoluteDifferencelndicator is equal to 1,
Set MatsCalcTrapAbsoluteDifference = the absolute value of the difference between the
MatsSorbentTrapSamplingTrain I.ist. H gConccnt rat io n for each train.
Set MatsCalcTrapPercentDifference = 100 * MatsCalcTrapAbsoluteDifference divided by the sum of the
MatsSorbentTrapSamplingTrainListHgConcentiation for each train.
Round MatsCalcTrapAbsoluteDifference to 2 decimal places.
Round MatsCalcTrapPercentDifference to 2 decimal place.
If MatsSorbentTrapRecord. AbsoluteDifferencelndicator is equal to 0,
If MatsSorbentTrapRecord.PmrcdT rap Agreement does not equal MatsCalcTrapPercentDifference,
Set MatsSorbentTrapValidExists to false.
Return result G.
Else
Set MatsSorbentTrapPairedTrapAgreementValid to true
Else
Environmental Protection Agency
Page 799 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Else if MatsSorbentTrapRecord.PalrcdT rap Agreement is less than or equal to 10,
If MatsSorbentTrapRecord.MODCCode is not equal to "01" OR "02",
Set MatsSorbentTrapValidExiststo false.
Return result H.
Else
Set MatsSorbentTrapPairedTrapAgreementValid to true.
Else if MatsSorbentTrapRecord.PmrcdT rap Agreement is less than or equal to 20, and the
MatsSorbentTrapRecord.HgSyslcmConccnlmUon is less than or equal to 1.0,
If MatsSorbentTrapRecord.MODCCode is not equal to "01" OR "02",
Set MatsSorbentTrapValidExists to false.
Return result I.
Else
Set MatsSorbentTrapPairedTrapAgreementValid to true.
Else
If MatsSorbentTrapRecord.MODCCode is not equal to "33",
Set MatsSorbentTrapValidExists to false.
Return result J.
Else
Set MatsSorbentTrapPairedTrapAgreementValid to true.
Else // AbsoluteDifferencelndicator is equal to 1
If MatsSorbentTrapRecord.PmrcdT rap Agreement is less than or equal to 0.03,
If MatsSorbentTrapRecord.PMKdJ rap Agreement does not equal
MatsCalc TrapAbsoluteDifferen ce.
Set MatsSorbentTrapValidExists to false.
Return result E.
Else
Set MatsSorbentTrapPairedTrapAgreementValid to true.
Else
Set MatsSorbentTrapValidExists to false.
Return result F.
Else // AbsoluteDifferencelndicator is null (not 0 or 1)
Set MatsSorbentTrapValidExists to false.
Return result K.
Environmental Protection Agency
Page 800 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
B
C
D
E
G
H
I
J
K
Usage:
1
Response
For [key], you did not report a [fieldname] value which is required if the sorbent trap
system MODC Code is [value].
For [key], you reported a [fieldname2], but did not report a [fieldname].
For [key], you reported a [fieldname] value which is not reported if the sorbent trap
system MODC Code is [value].
The [fieldname] value for [key] should be reported to two decimal places.
The [fieldname] is inconsistent with the value [value 1] calculated from the reported
[key] records used in the calculation.
For [key], you reported an Absolute Difference Indicator of 1 that can only be used if
the absolute difference between the Hg concentrations of the paired traps is less than or
equal to 0.03 ug/m3.
The [fieldname] is inconsistent with the value [value2] calculated from the reported
[key] records used in the calculation.
For [key], you reported a passing Paired Trap Agreement that is not consistent with an
MODC Code other than 01 or 02.
For [key], you reported a passing Paired Trap Agreement that is not consistent with an
MODC Code other than 01 or 02.
For [key], you reported a failed Paired Trap Agreement that is not consistent with an
MODC Code other than 33.
For [key], you did not report a [fieldname2] value which is required if the sorbent trap
system MODC Code is [value].
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Process/Category: Emissions Data Evaluation Report ¦
¦ MATS Sorbent Trap Evaluation
Environmental Protection Agency
Page 801 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSTRP-12
Check Name:
Related Former Checks:
Hg System Concentration Validation and Re-calculation
Applicability:
Description:
Specifications:
Set MatsCalcHgSystemConcentration equal to null.
If the MatsSorbentTrapPairedTrapAgreementValid is equal to true,
If the MatsSorbentTrapRecord.HgSxsicmConccnlmlion is null,
If the MatsSorbentTrapRecord.MODCCode is not "34" or "35",
Set MatsSorbentTrapValidExiststo false.
Return result A.
Else
If the MatsSorbentTrapRecord.MODCCode is not "01", "02", "32", or 33,
Set MatsSorbentTrapValidExists to false.
Return result B.
Else if the MatsSorbent TrapRecord. H g S y s t e m C o nc e n t ra t i o n is not reported in scientific notation rounded to three
significant figures, keeping one to the left of the decimal point (x.xx-E-x).
Set MatsSorbentTrapValidExists to false.
Return result C.
If MatsSorbentTrapRecord.MODCCode is equal to "32" ,
Set HgConcentrationCalculation= multiply 1.111 times the
MatsSorb en t TrapSampling Train /. ist. H g C o nc c lit ra t i o n entry where
MatsSorb en t TrapSampling Train /. ist. T ra i nQ A S t a t u s C ode is equal to "PASSED".
Else if MatsSorbentTrapDataRecord.MODCCode is equal to "33" ,
Set HgConcentrationCalculation = the higher of the
MatsSorbentTrapSamplingTrainList.HgConccnirdtion entries for the sampling train components.
Else //MODC "01" or "02"
Set HgConcentrationCalculation = the sum of the MatsSorbentTrapSamplingTrainList. HgConccnt ration
for each train divided by two.
Set MatsCalcHgSystemConcentration to HgConcentrationCalculation in scientific notation with three significant
digits, keeping one to the left of the dicmal point (x.xxEx).
If MatsSorbentTrapRecord.HgSxs[cmConccn[n\[\on does not equal MatsCalcHgSystemConcentration,
Set MatsSorbentTrapValidExists to false.
Return result D.
Else
Environmental Protection Agency
Page 802 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
A
B
C
D
Usage:
1
Response
For [key], you did not report a [fieldname] value which is required if the sorbent trap
system MODC Code is [value].
For [key], you reported a [fieldname] value which is not reported if the sorbent trap
system MODC Code is [value].
The [fieldname] value in the [key] records is not reported in scientific notation rounded
to three significant figures, with one digit to the left of the decimal point.
The [fieldname] is inconsistent with the value [value 1] calculated from the reported
[key] records used in the calculation.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Process/Category: Emissions Data Evaluation Report ¦
¦ MATS Sorbent Trap Evaluation
Environmental Protection Agency
Page 803 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSTRP-13
Check Name:
Update Sorbent Trap Parameters
Related Former Checks:
Applicability:
Description:
Specifications:
For SorbentTrapDictionary entry where the key is equal to MatsSorbentTrapRecord.TrapId. set:
1) SorbentTrapValidExists set to MatsSorbentTrapValidExists.
2) SamplingTrainProblemComponentExists set to MatsSamplingTrainProblemComponentExists.
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS Sorbent Trap Evaluation
Environmental Protection Agency
Page 804 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
MATSTRP-14
Check Name:
Number of Unit Operating Days
Related Former Checks:
Applicability:
Description:
Specifications:
If MatsSorbentTrapDictionary.OperatingPateList where MatsSorbentTrapDictionary key is equal to MatsSorbentTrapRecord.Trapid
contains more than 14 dates,
Return result A.
Results:
Result
A
Response
You reported a sorbent trap sampling period longer than the maximum 14 operating
days.
Severity
Critical Error Level 1
Usage:
1 Process/Category: Emissions Data Evaluation Report MATS Sorbent Trap Last Hour Evaluation
Environmental Protection Agency
Page 805 of 850
-------
Draft ECMPS Emissions Check Specifications
Check Category:
RATA Status
6/17/2015 12:00:00AM
Environmental Protection Agency
Page 806 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
RATSTAT-1
Check Name:
Check Low Sulfur and FLOW Exemptions
Related Former Checks:
Applicability:
Description:
Specifications:
Set CurrentRATAStatus = null.
Set OverrideRATABAF = null.
Set MaxLevelCount = null.
Set FlowRATAExemption = false.
if (O a Statu sSystem Typ eCode begins with "S02")
Locate a record in TestExtensionExemptionRecords for the location where the SystemID is equal to the QaStatusSystemld, the
reporting period is the Current Reporting Period, AND the ExtensionExemptionCode is equal to "LOWSYTD"
if (TestExtensionExemptionRecords is found)
Set CurrentRATAStatus = "IC-Exempt"
else
Locate a record in MonitorQualiJicationRecordsByHour for the hour and where MonitoringLocationld =
CurrentMonitorLocationld
and the QualificationTypeCode is equal to "LOWSULF".
if (MonitorQualificationRecordsByHour is found)
Set CurrentRATAStatus = "IC-Exempt".
else if (QaStatusSystemTypeCode = "FLOW")
Set PeakingBypass = false.
if (CurrentEntityType is equal to "CS" or "MS")
Locate the record in LocationAttributeRecordsByHourLocation for the hour and location.
if (LocationAttributeRecords. By pass I nd == 1)
Set PeakingBypass = true.
else
Set PeakingBypass = true.
For each record in UnitStackConfigurationRecordsByHourLocation for the hour and stack location
Locate a record in MonitorQualificationRecordsByHour for the hour where MonitoringLocationld = the
unit location in the UnitStackConfigurationRecordsByHourLocation record and QualificationTypeCode
is equal to "PK" or "SK".
if (MonitorQualificationRecordsByHour is NOT found)
Set PeakingBypass = false.
Exit for.
Environmental Protection Agency
Page 807 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
else if (CurrentUnitisPeaking)
Set P eakingBypass = true,
if (PeakingBypass)
Set MaxLevelCount = 1.
else
Locate a record in MonitorQualificationRecordsByHour for the hour where the MonitoringLocationld =
CurrentMonitorLocationld and QualificationTypeCode is equal to "PRATA1"
if (MonitorQualificationRecordsByHour is found)
Set MaxLevelCount = 1.
else
Locate a record in MonitorQualificationRecordsByHour for the hour where MonitoringLocationld =
CurrentMonitorLocationld and the QualificationTypeCode is equal to "PRATA2"
if (MonitorQualificationRecordsByHour is found)
Set MaxLevelCount = 2.
else
Set MaxLevelCount = 3.
Append QaStatusSystemld to FLOWSystemlDArray for the location.
Locate a record in TestExtensionExemptionRecords for the location where the SystemID is equal to the QaStatusSystemld, the
ComponentID is equal to the the QaStatusComponentld the reporting period is the Current Reporting Period, AND the
ExtensionExemptionCode is equal to "FLOWEXP"
if (TestExtensionExemptionRecords is found)
Set FlowRA TAExemption = true.
Results:
Result Response Severity
Environmental Protection Agency
Page 808 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Usage:
1
Process/Category:
Emissions Data Evaluation Report
C02/02 RATA Status Evaluation
2
Process/Category:
Emissions Data Evaluation Report
H20 RATA Status Evaluation
3
Process/Category:
Emissions Data Evaluation Report
H20M RATA Status Evaluation
4
Process/Category:
Emissions Data Evaluation Report
Hg RATA Status Evaluation
5
Process/Category:
Emissions Data Evaluation Report
NOX RATA Status Evaluation
6
Process/Category:
Emissions Data Evaluation Report
NOXC RATA Status Evaluation
7
Process/Category:
Emissions Data Evaluation Report
S02 RATA Status Evaluation
8
Process/Category:
Emissions Data Evaluation Report
Stack Flow RATA Status Evaluation
Environmental Protection Agency
Page 809 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
Check Code: RATSTAT-2
Check Name: Locate Most Recent Prior RATA Test
Related Former Checks:
Applicability:
Description:
Specifications:
Set PriorRA TA Record = null.
Set InvalidRATARecord = null.
Set ApplicableSystemlDList = null.
If Flow RATA Exemption is true,
Locate all MonitorSystemComponentRecordsforHourandLocation for the location and hour where the ComponentID is equal to
QaStatusComponentld.
For each record found,
Append MonitorSystemComponentRecordsforHourandLocation.SystemiD to the ApplicableSystemlDList
else
Append QaStatusSystemld to the ApplicableSystemlDList
Locate the most recent record in RATATestRecordsByLocationForQAStatus for the location where the SystemID is in the
ApplicableSystemlDList and the TestResultCode is not equal to "INVALID" and the EndDate/Hour is prior to the CurrentDateHour
if (RATATestRecordsByLocationForQAStatus is found)
Set Prior RA TA Record = the found record in RATATestRecordsByLocationForQAStatus.
if (CurrentRATAStatus is null)
Locate the most recent record in RATATestRecordsByLocationForQAStatus for the location where the SystemID is in the
ApplicableSystemlDList and the EndDate/Hour is prior to the CurrentDateHour and the EndDate/Hour is greater than the
Prior RA TA Record EndDatc/H our and the TestResultCode is equal to "INVALID".
if (RATATestRecordsByLocationForQAStatus is found)
Set InvalidRATARecord = the found record in RATATestRecordsByLocationForQAStatus.
else
Locate the most recent record in RATATestRecordsByLocationForQAStatus for the location where the SystemID is in the
ApplicableSystemlDList and the TestResultCode is equal to "INVALID" and the EndDate/Hour is prior to the CurrentDateHour
if (RATATestRecordsByLocationForQAStatus is found)
Set InvalidRATARecord = the found record in RATATestRecordsByLocationForQAStatus.
Results:
Result Response Severity
Environmental Protection Agency
Page 810 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Usage:
1
Process/Category:
Emissions Data Evaluation Report
C02/02 RATA Status Evaluation
2
Process/Category:
Emissions Data Evaluation Report
H20 RATA Status Evaluation
3
Process/Category:
Emissions Data Evaluation Report
H20M RATA Status Evaluation
4
Process/Category:
Emissions Data Evaluation Report
Hg RATA Status Evaluation
5
Process/Category:
Emissions Data Evaluation Report
NOX RATA Status Evaluation
6
Process/Category:
Emissions Data Evaluation Report
NOXC RATA Status Evaluation
7
Process/Category:
Emissions Data Evaluation Report
S02 RATA Status Evaluation
8
Process/Category:
Emissions Data Evaluation Report
Stack Flow RATA Status Evaluation
Environmental Protection Agency
Page 811 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: RATSTAT-3
Check Name: Locate Most Recent Prior Event
Related Former Checks:
Applicability:
Description:
Specifications:
Set Prior RA TA E vent Record = null.
If (CurrentRATAStatus is null)
Locate the most recent record in QACertificationEventRecords where the SystemID is in the ApplicableSystemlDList and
RATARequired is equal to "Y" and the QACertEventDate is either:
a) prior to the CurrentDateHour OR
b) equal to both the CurrentDateHour and the ConditionalBeginDate/Hour;
AND either:
a) PriorRA TA Record is null OR
b) QACertEventDate/Hour is after the PriorRA TA Record. EndDatc/H our OR
c) QACertEventDate/Hour is equal to the PriorRA TA Record. E nd D a tc/ H o u r AND (TestCompletionDate is null or the
TestCompletionDate/Hour is after the PriorRA TA Record. E ndDa t c/H o ur)
AND either:
a) Annual Reporting Requirement is equal to true OR
b) QACertEventDate/Hour is on or after April 1 of the year of CurrentDateHour
AND either:
a) QaStatusSystemTypeCode NOT is set (HCL, HF, HG, ST) OR
b) QACertEventCode is in set (101, 110, 125, 130)
if (QACertificationEventRecords is found)
Set PriorRA TA E vent Record = the found record in QACertificationEventRecords.
if (PriorRA TAEventRecord is null)
if (PriorRA TA Record is null)
Set CurrentRATAStatus = "OOC-No Prior Test or Event"
if (CurrentMhvParameter == "FLOW")
Set OverrideRA TAIiAF =1.0
else if (InvalidRATARecord is not null AND PriorRA 7>l£'v'6'rt?/?6'cwY/.QACcrtE\ cntDatc/Hour is after
InvalidRA TA Record. E ndDa tc/H o u r)
Locate the earliest record in RATATestRecordsByLocationForQAStatus for the location where the SystemID is equal to
the QaStatusSystemld and the EndDate/Hour is after the PriorRA TA E vent Record. Q A C c rt E v e n t D a tc/ H o u r and the
EndDate/Hour is prior to CurrentDateHour and the TestResult is equal to "INVALID"
if (RATATestRecordsByLocationForQAStatus is found)
Set InvalidRATARecord = the found record in RATATestRecordsByLocationForQAStatus.
Environmental Protection Agency
Page 812 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
else
Set InvalidRATARecord = null.
Results:
Result Response
Usage:
1 Process/Category: Emissions Data Evaluation Report
2 Process/Category: Emissions Data Evaluation Report
3 Process/Category: Emissions Data Evaluation Report
4 Process/Category: Emissions Data Evaluation Report
5 Process/Category: Emissions Data Evaluation Report
6 Process/Category: Emissions Data Evaluation Report
7 Process/Category: Emissions Data Evaluation Report
8 Process/Category: Emissions Data Evaluation Report
Severity
C02/02 RATA Status Evaluation
H20 RATA Status Evaluation
H20M RATA Status Evaluation
Hg RATA Status Evaluation
NOX RATA Status Evaluation
NOXC RATA Status Evaluation
S02 RATA Status Evaluation
Stack Flow RATA Status Evaluation
Environmental Protection Agency
Page 813 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
RATSTAT-4
Check Name:
Check RATA Result
Related Former Checks:
Applicability:
Description:
Specifications:
if (CurrentRATAStatus is null and Prior RA TA Record is not null and Prior RATAEventRecord is null)
Set EvaluateMultiLevelRATA = true.
if (PriorRA 7/4/?ecwY/.Q ANccdsEvaluationFlag = "Y")
Set CurrentRATAStatus = "Prior Test Not Yet Evaluated".
else if (Prior RA TA Record. Te s t Re s u 11C o de = null or Prior RA TA Record. Te s t Re s u 11C o de = "FAILED" or
PriorRA TARecord.T cstRcsultCodc = "ABORTED")
Locate the most recent record in QACertificationEventRecords where the SystemID is in the ApplicableSystemlDList and
RATARequired is equal to "Y" and the ConditionalBeginDate/Hour is:
a) on or prior to the CurrentDateHour AND
b) on or after the PriorRA TA Record. EndDatc/H our: AND
c) Annual Reporting Requirement is equal to true OR QACertEventDate/Hour is on or after April 1 of the year of the
CurrentDateHour.
if {QACertificationEventRecords is found)
Set Prior RAT AEventRecord = found record in QACertificationEventRecords.
elseif (PriorRA TARecord.T cstRcsultCodc = null)
Set CurrentRATAStatus = "OOC-Prior Test Has Critical Errors".
if (CurrentMhvParameter == "FLOW")
Set OverrideRATABAF = PriorRA 7/4/?6'ewl/?6'cwY/.0\cral IB ias Adjust incut Factor.
elseif (PriorRATARecord.TestResultCode= "ABORTED")
Set CurrentRATAStatus = "OOC-Prior Test Aborted".
if (CurrentMhvParameter == "FLOW")
Set OverrideRATABAF = PriorRA 7>l/?6'cwY/.0\cral IB ias Adjust incut Factor.
Environmental Protection Agency
Page 814 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result Response
Usage:
1 Process/Category: Emissions Data Evaluation Report
2 Process/Category: Emissions Data Evaluation Report
3 Process/Category: Emissions Data Evaluation Report
4 Process/Category: Emissions Data Evaluation Report
5 Process/Category: Emissions Data Evaluation Report
6 Process/Category: Emissions Data Evaluation Report
7 Process/Category: Emissions Data Evaluation Report
8 Process/Category: Emissions Data Evaluation Report
Severity
C02/02 RATA Status Evaluation
H20 RATA Status Evaluation
H20M RATA Status Evaluation
Hg RATA Status Evaluation
NOX RATA Status Evaluation
NOXC RATA Status Evaluation
S02 RATA Status Evaluation
Stack Flow RATA Status Evaluation
Environmental Protection Agency
Page 815 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
RATSTAT-5
Check Name:
Determine Event Conditional Status
Related Former Checks:
Applicability:
Description:
Specifications:
Set SubsequentRATARecord = null.
Set RATAMissingOpDatalnfo = null.
Set RA TA Event Operating Level Count = null.
if (CurrentRATAStatus is null and Prior RA TA E vent Record is not null)
if (PwwTf/l 7/4£"vewf/tecwf/. Conditional DataBeginDatc/Hour is null or CurrentDateHour is prior to the
Prior RA TAEventRecord. ConditionalDataBeginDate/Hour)
Locate the earliest record in RATATestRecordsByLocationForQAStatus where the SystemID is equal to the
Prior RA TAEventRecord. Sy stc m ID, the TestResult is not equal to "INVALID" and the EndDate/Hour is on or after the
PriorRA 7>4 £v'677?/?6'ew/y/.0yc rail Bias Adjust merit Factor.
else if (RA TA Test Records By Location ForOAStatus.TcsiRcsuhCodc = "FAILED")
Set CurrentRATAStatus = "OOC-Recertification Test Failed".
if (CurrentMh vParameter == "FLOW")
Set OverrideRATABAF = SubsequentRA 7/4/?6'cmy/.Overall Bias Adjust merit Factor.
else if (RA TA Test Records By Location ForOAStatus.TcsiRcsuhCodc = "ABORTED")
Set CurrentRATAStatus = "OOC-Recertification Test Aborted".
if (CurrentMh vParameter == "FLOW")
Set OverrideRATABAF = SubsequentRA 7/4Overall Bias Adjust merit Factor.
Set CurrentRATAStatus = "OOC-Event".
Set OverrideRATABAF = 1.0.
else
else
if (PriorRA TA Record is null)
RequiredLevelCount = MaxLevelCount
Environmental Protection Agency
Page 816 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
else (if PriorRA TAEvcntRccord.RAT A3 Required is equal to "Y")
RequiredLevelCount = 3
else (if PriorRA TAEvcntRccord.RATA2Rcquircd is equal to "Y")
RequiredLevelCount = 2
else
RequiredLevelCount = 1
If (number of levels in RA TA TcstRccords/iyLocationForOAStatus.OpLcvdCodcLisl is less than
RequiredLevelCount)
Set CurrentRATAStatus = "OOC-Incomplete Recertification".
if (CurrentMh vParameter == "FLOW")
Set OverrideRATABAF = SubsequentRA 7>l/?6'cwY/.0\crallBiasAdjustincntFactor.
else
Set RA TA Event Operating Level Count to the RequiredLevelCount.
If (InvalidRATARecord is null)
Locate the earliest record in RATATestRecordsByLocationForQAStatus where the SystemID is equal to
the PriorRA TAEventRecord. SystemID, the TestResult is equal to "INVALID" and the EndDate/Hour is
on or after the PwmT?/! yMEvewf/fecwf/. Conditional DataBcginDate/Hour and is before the
EndDate/EndHour of the RATATestRecordsByLocationForQAStatus record retrieved above.
if (RATATestRecordsByLocationForQAStatus is found)
Set InvalidRATARecord = the found record in RATATestRecordsByLocationForQAStatus.
else
if (PriorRA TAEventRecord. R ATA3 Rcqui red is equal to "Y")
Set RA TA Event Operating Level Count to 3.
else (if PriorRA TAEvcntRccord.RATA2Rcquircd is equal to "Y")
Set RA TA Event Operating Level Count to 2.
else
Set RA TA Event Operating Level Count to 1.
if (CurrentRATAStatus is null AND Annual Reporting Requirement == false)
If (SubsequentRA TARecord is not null and SubsequentRA TA Record. E ndDa tc/H o u r is greater than October 30th
of the year of the CurrentDateHour) OR (SubsequentRA TARecord is null and the CurrentDateHour is in the 3rd
quarter))
Set CurrentRATAStatus = "OOC-Conditional Period Expired".
if (CurrentMh vParameter == "FLOW")
Set OverrideRATABAF = 1.0.
if (CurrentRATAStatus is null)
if (PriorRA TAEvcntRccord.RATACcrtEvent == "Y") and (PriorRA TAEvcntRccord. SystcmTypcCodc is NOT in
set (HCL, HF, HG, ST))
Environmental Protection Agency
Page 817 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
if ((CurrentMhvParameter <> "FLOW" and Prior RA TA Event Record.ExcnlCodc = 125) or
0CurrentMhvParameter == "FLOW" and Prior RA TAEventRecord.E\c\\{CoAc = 305))
if (the associated BeginDate of the system in the Prior RA TA E vent Record is null)
Set CurrentRATAStatus = "Invalid Monitor System"
else
If (the associated SystemTypeCode of the system in the Prior RA TA E vent Record ==
"S02")
Locate the record in LocationProgramRecordsByHourLocation with the latest
UnitMonitorCertBeginDate where the ProgramCode is in set {ARP, CAIRS02,
TRS02G1, TRS02G2} and the UnitMonitorCertBeginDate is ON OR BEFORE
the associated BeginDate of the system in the PriorRA TAEventRecord.
If (the record in LocationProgramRecordsByHourLocation is not found)
Locate the record in LocationProgramRecordsByHourLocation with
the latest EmissionsRecordingBeginDate where the ProgramCode is in
set {ARP, CAIRS02, TRS02G1, TRS02G2} and the
EmissionsRecordingBeginDate is ON OR BEFORE the associated
BeginDate of the system in the PriorRA TAEventRecord.
else if (the associated SystemTypeCode of the system in the PriorRA TAEventRecord ==
"NOX")
Locate the record in LocationProgramRecordsByHourLocation with the latest
UnitMonitorCertBeginDate where the ProgramCode is in set {ARP, NBP,
NHNOX, CAIRNOX, CAIROS, TRNOX, TRNOXOS, SIPNOX} and the
UnitMonitorCertBeginDate is ON OR BEFORE the associated BeginDate of the
system in the PriorRA TAEventRecord.
If (the record in LocationProgramRecordsByHourLocation is not found)
Locate the record in LocationProgramRecordsByHourLocation with
the latest EmissionsRecordingBeginDate where the ProgramCode is in
set {ARP, NBP, NHNOX, CAIRNOX, CAIROS, TRNOX, TRNOXOS,
SIPNOX} and the EmissionsRecordingBeginDate is ON OR BEFORE
the associated BeginDate of the system in the Prior RA TA E ventRecord.
else if (the associated SystemTypeCode of the system in the PriorRA TAEventRecord ==
"NOXC")
Locate the record in LocationProgramRecordsByHourLocation with the latest
UnitMonitorCertBeginDate where the ProgramCode is in set {NBP, NHNOX,
CAIRNOX, CAIROS, TRNOX, TRNOXOS, SIPNOX} and the
UnitMonitorCertBeginDate is ON OR BEFORE the associated BeginDate of the
system in the PriorRA TAEventRecord.
If (the record in LocationProgramRecordsByHourLocation is not found)
Locate the record in LocationProgramRecordsByHourLocation with
the latest EmissionsRecordingBeginDate where the ProgramCode is in
set {NBP, NHNOX, CAIRNOX, CAIROS, TRNOX, TRNOXOS,
SIPNOX} and the EmissionsRecordingBeginDate is ON OR BEFORE
the associated BeginDate of the system in the Prior RA TA E ventRecord.
else
Locate the record in LocationProgramRecordsByHourLocation with the latest
Environmental Protection Agency
Page 818 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
UnitMonitorCertBeginDate where the UnitMonitorCertBeginDate is ON OR
BEFORE the associated BeginDate of the system in the
PriorRA TAEventRecord.
If (the record in LocationProgramRecordsByHourLocation is not found)
Locate the record in LocationProgramRecordsByHourLocation with
the latest EmissionsRecordingBeginDate where the
EmissionsRecordingBeginDate is ON OR BEFORE the associated
BeginDate of the system in the Prior RATAEventRecord.
If (the record in LocationProgramRecordsByHourLocation is not found)
Set CurrentRATAStatus = 'Missing Program".
else if (LocationProgramRecordsByHourLocationUmtMomtorCertDeadline is not null)
if (CurrentDate is prior to the
LocationProgramRecordsByHourLocation.UmtMomtorCQrtDeadlme)
Set CurrentRATAStatus = "IC-Conditional".
else
Set CurrentRATAStatus = "OOC-Conditional Period Expired".
if (CurrentMhv Parameter == "FLOW")
Set OverrideRATABAF = 1.0.
else
if (CurrentDate is prior to the
L ocation ProgramRecordsHyHourLocation. U ni t Mo n i to rCe rt B eg i n Da tc + 180
days)
Set CurrentRATAStatus = "IC-Conditional".
else
Set CurrentRATAStatus = "OOC-Conditional Period Expired".
if (CurrentMhvParameter == "FLOW")
Set OverrideRATABAF = 1.0.
If (the number of calendar days ON OR AFTER the PriorRA TA E ventRecord. Q A C c rt E v e n t D a tc
and ON OR BEFORE the CurrentDateHour > 180)
Set CurrentRATAStatus = "OOC-Conditional Period Expired".
if (CurrentMh vParameter == "FLOW")
Set OverrideRATABAF = 1.0.
else if (the quarter of the PriorRA TA EventRecord.Q ACc rt E vent Datc is equal to the quarter of the
CurrentDateHour)
If (the number of calendar days ON OR AFTER the
PriorRA TA EventRecord. Q A C c rt E v e n t D a t c and ON OR BEFORE the CurrentDateHour
>90)
If (Rpt Period Op Hours Accumulator Array for the location == -1)
Set CurrentRATAStatus = "Invalid Op Data".
Environmental Protection Agency
Page 819 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
else if (the number of calendar days ON OR AFTER the
Prior RA TA E vent Record. Q A C c rt Ey e n t D a t c and ON OR BEFORE the
CurrentDateHour is equal to Rpt Period Op Days Accumulator Array for the
location)
Set CurrentRATAStatus = "OOC-Conditional Period Expired".
if (CurrentMhvParameter == "FLOW")
Set OverrideRATABAF = 1.0.
else
Set CurrentRATAStatus = "IC-Conditional".
else
Set CurrentRATAStatus = "IC-Conditional".
else if (Prior RA TA E ventRecord. IVT i nO p Day s P rio rQua rtc r is null)
Set PriorRA TA E ventRecord. IVT i nOp Day s P ri o rQua rtc r = 0
Set PriorRATAEventRecord.MaxOpDaysPriorQuarter = 0
For each quarter beginning with the quarter of the
PriorRA TAEventRecord. Q ACc rtEvent Datc and continuing through the quarter BEFORE
the CurrentDateHour:
if (Earliest!.ocationReportDate <= the last day of the quarter being checked)
Locate the record in OperatingSuppDataRecordsbyLocation where the
OpTypeCode is equal to "OPDAYS" and the reporting period is equal to
the quarter being checked.
if (OperatingSuppDataRecordsbyLocation is not found)
Locate the record in ReportingFrequencyBy Location where
CalendarYear/Quarter are equal to the quarter being checked.
if found, and (the quarter being checked is 2 or 3, or
ReportingFrequency/iyLocation.RcpovUngFrcqucncyCodc is
equal to "Q"),
Set PriorRA TA EventRecord. IVI i nO pD ay s P rio rQua rtc r
= -1
Set RATAMissingOpDatalnfo = "[YEAR] Q[QTR]"
(where [YEAR] is the year of the quarter being checked
and [QTR] is the number of the quarter being checked.)
exit for.
else
If the quarter being checked is the quarter of the
PriorRA TAEventRecord. Q ACertEventDate
If (OperatingSuppDataRecordsby Location.OpVa\uc
MINUS the number of calendar days in the quarter
being checked that are PRIOR to the
PriorRATAEventRecord.QACertEventDate > 0)
Set
Environmental Protection Agency
Page 820 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
PriorRATAEventRecordMmO^DaysVnorQvia
rter =
()peratingSuppl)ataRecordsby Location. Op Va 1
ue MINUS the number of calendar days in the
quarter being checked that are PRIOR to the
PriorRA TA E ventRecord. Q A Cc rt E v e n t D a tc
If (()peratingSuppDataRecordsbyL ocation. Op Va 1 lie is
less than the number of calendar days in the quarter
being checked that are ON OR AFTER the
Prior RA TA E ventRecord. Q A C c rt E v e n t D a tc)
Set
Prior RA TA E ventRecord. IVT a\0 p Day s P rio rQua
rter =
OperatingSuppDataRecordsbyLocation. Op Val
ue.
else
Set
Prior RA TA E ventRecord. IVT a\0 p Day s P rio rQua
rter = the number of calendar days in the
quarter being checked that are ON OR AFTER
the
PriorRATAEventRecord.QACertEventDate.
Set PriorRA TAEventRecord. M iiiO p D ay s P ri o rQ ua rtc r
= Prior RA 7/4£V677?/?6'ew 90)
Set CurrentRATAStatus = "OOC-Conditional Period Expired".
if (CurrentMh vParameter == "FLOW")
Set OverrideRATABAF = 1.0.
else if (Prior RA TA E ventRecord. IVI a \ O p D ay s P ri o rQ ua rtc r + Rpt Period Op Days
Accumulator Array for the Location > 90)
Set CurrentRATAStatus = "Undetermined-Conditional Data".
else
Set CurrentRATAStatus = "IC-Conditional".
else
Set CurrentRATAStatus = "IC-Conditional".
else
Environmental Protection Agency
Page 821 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
If (the quarter of the PriorRA 7/4£V677?/?6'cw 720,
Set CurrentRATAStatus = "OOC-Conditional Period Expired".
if (CurrentMh vParameter == "FLOW")
Set OverrideRATABAF = 1.0.
else
Set CurrentRATAStatus = "IC-Conditional".
if (PriorRA TA E vent Record. IVI i nO pH o u rs P ri o rQua rtc r is null)
Set PriorRA TA E ventRecord. IVI i nOp H o u rs P rio rQua rtc r = 0
Set PriorRA TA E ventRecord. IVI a\Op H o u rs P ri o rQua rtc r = 0
for each quarter beginning with the quarter of the
PriorRA TAEventRecord. Condi t io na 1Begi nDa tc and continuing through the quarter
BEFORE the CurrentDateHour:
if (Earliest!.ocationReportDate <= the last day of the quarter being checked)
if {Annual Reporting Requirement == false AND the quarter being
checked == 2)
Locate the record in OperatingSuppDataRecordsbyLocation
where the OpTypeCode is equal to "OSHOURS" and the
reporting period is equal to the quarter being checked.
else
Locate the record in OperatingSuppDataRecordsbyLocation
where the OpTypeCode is equal to "OPHOURS", FuelCode is
null, and the reporting period is equal to the quarter being
checked.
if (OperatingSuppDataRecordsbyLocation is not found)
Locate the record in ReportingFrequencyByLocation where
CalendarYear/Quarter are equal to the quarter being checked.
if found, and (the quarter being checked is 2 or 3, or
ReportingFrequency/iyLocation.RcpovUngFrcqucncyCodc is
equal to "Q"),
Set PriorRA TA E ventRecord. IVI i nO pH o u rs P ri o rQua rtc r
= -1
Set RATAMissingOpDatalnfo = "[YEAR] Q[QTR]"
(where [YEAR] is the year of the quarter being checked
and [QTR] is the number of the quarter being checked.)
exit for.
Environmental Protection Agency
Page 822 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
If the quarter being checked is the quarter of the
Prior RA TAEventRecord. ConditionalBeginDate
If (()peratingSuppI)ataRecordsbyLocation. Op Va 1 lie
MINUS the number of calendar hours in the quarter
being checked that are PRIOR to the
PriorRA 7>4 £v'677?/?6'ew
0)
Set
PriorRA TA E vent Record. IVI i nOp H o u rs P rio rQu
arter =
()peratingSuppI)ataRecordshy Location. Op Va 1
ue MINUS the number of calendar hours in the
quarter being checked that are PRIOR to the
PriorRA 7M£Vewf/?ec«/Y/.ConditionalBcginDat
e/Hour
If (()peratingSuppl)ataRecordsbyL ocation. Op Va 1 lie is
less than the number of calendar hours in the quarter
begin checked that are ON OR AFTER the
Conditional BcginDatc/Hour)
Set
PriorRA TA E ventRecord. IVI a \ O p H o u rs P ri o rQ u
arter =
()peratingSuppI)ataRecordsby Location. Op Va 1
ue.
else
Set
PriorRA TA E ventRecord. IVI a \ O p H o u rs P ri o rQ u
arter = the number of calendar hours in the
quarter being checked that are ON OR AFTER
the
PriorRA 7M£Vewf/?ec«/Y/.ConditionalBcginDat
e/Hour.
Set PriorRA TAEventRecord. IVI i nOpHoursP rio rQua rtcr
= PriorRA TA EventRecord. IVI i nOpHoursP rio rQuartcr +
()peratingSuppl)ataRecordsbyL ocation. Op Va 1 lie.
Set PriorRA TA E ventRecord. IVI a\0 p H o u rs
PriorQuarter =
PriorRA TA E ventRecord. IVI a\Op H o u rs P rio rQua rtc r +
()peratingSuppl)ataRecordsbyL ocation. Op Va 1 lie.
if (PriorRA TA E ventRecord. IVI i nO p H o u rs P ri o rQ ua rtc r == -1)
set CurrentRATAStatus to "Missing Op Data"
else if (Rpt Period Op Days Accumulator Array for the location == -1)
if (PriorRA TA EventRecord. IVI i nOpH ours Prio rQua rtc r > 720)
Environmental Protection Agency
Page 823 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Set CurrentRATAStatus = "OOC-Conditional Period Expired".
if (CurrentMh vParameter == "FLOW")
Set OverrideRATABAF = 1.0.
else
Set CurrentRATAStatus = "Invalid Op Data".
else
if (PriorRA TA E vent Record. IVI i nOp H on rs P rio rQua rtc r + Rpt Period Op Hours
Accumulator Array for the Location > 720)
Set CurrentRATAStatus = "OOC-Conditional Period Expired".
if (CurrentMh vParameter == "FLOW")
Set OverrideRATABAF = 1.0.
else if (Prior E ventRecord. IVI a \ O p H o u rs P ri o rQ ua rtc r + Rpt Period Op Hours
Accumulator Array for the Location > 720)
Set CurrentRATAStatus = "Undetermined-Conditional Data".
else
Set CurrentRATAStatus = "IC-Conditional".
Results:
Result Response Severity
Usage:
1
Process/Category:
Emissions Data Evaluation Report
C02/02 RATA Status Evaluation
2
Process/Category:
Emissions Data Evaluation Report
H20 RATA Status Evaluation
3
Process/Category:
Emissions Data Evaluation Report
H20M RATA Status Evaluation
4
Process/Category:
Emissions Data Evaluation Report
Hg RATA Status Evaluation
5
Process/Category:
Emissions Data Evaluation Report
NOX RATA Status Evaluation
6
Process/Category:
Emissions Data Evaluation Report
NOXC RATA Status Evaluation
7
Process/Category:
Emissions Data Evaluation Report
S02 RATA Status Evaluation
8
Process/Category:
Emissions Data Evaluation Report
Stack Flow RATA Status Evaluation
Environmental Protection Agency
Page 824 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: RATSTAT-6
Check N ame: Evaluate Prior Multi-Level RAT A
Related Former Checks:
Applicability:
Description:
Specifications:
Set PriorRatalsAlternateSingleLevelRATA = false.
Set ThreeLoadRATAExpirationDate to null.
If (CurrentMh vParameter == "FLOW" AND PriorRA TA Record is not null AND CurrentRATAStatus is null, starts with "IC", or starts
with "Undetermined")
Set PriorRatalsAlternateSingleLevelRATA = true.
Set Prior MultilevelRA TARecord = null.
Set InvalidMultiLevelRATARecord = null.
Set Prior MaxLevelRA TARecord = null.
if (the number of levels in PriorRA TA Record. O p Lc vc 1 Code Li st is greater than or equal to the MaxLevelCount)
Set PriorRatalsAlternateSingleLevelRATA = false,
exit check.
else if (PriorRA TARecord.0\~>Lc\c\CoAcL\s{ contains 2 levels)
Set PriorRataIsAlternateSingleLevelRATA = false,
if (MaxLevelCount <> 3)
exit check.
else if (AnnualReportingRequiremnt == true)
if (PriorRA 7>l/?6'co/Y/.OpLc\clCodcList contains 1 level and PriorRA TA Record. Tc s t C1 a i m Code == "SLC")
Set PriorRataIsAlternateSingleLevelRATA = false.
if (PriorRatalsAlternateSingleLevelRATA == true AND RATAEventOperatingLevelCount is null or less than 2)
Locate the most recent record in RATATestRecordsByLocationForQAStatus for the location where the SystemID is equal
to the Prior RATARecord. SystemID and the TestResultCode is not equal to "INVALID" and the EndDate/Hour is prior to
the PriorRA 7/1EndDate/Hour. and (the number of operating levels in the OpLevelCodeList is greater than or equal
to 2 or the TestClaimCode == "SLC").
if (RATATestRecordsByLocationForQAStatus is found)
Set PriorMultiLevelRA TA Record = the found record in RATATestRecordsByLocationForQAStatus.
Locate the most recent record in RATATestRecordsByLocationForQAStatus for the location where the SystemID
is equal to the PriorRA TA Record. Sy stem ID and the EndDate/Hour is prior to the
PriorRA 7M/?ec«/Y/. EndDate/Hour and the EndDate/Hour is greater than the
Prior Mu ItiL eve/RA TA Record. EndDate/Hour and the TestResult is equal to "INVALID", and (the number of
operating levels the OpLevelCodeList is greater than or equal to 2 or the TestClaimCode == "SLC").
if (RATATestRecordsByLocationForQAStatus is found)
Set InvalidMultiLevelRATARecord = the found record in RATATestRecordsByLocationForQAStatus.
Environmental Protection Agency
Page 825 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Locate the most recent record in RATATestRecordsByLocationForQAStatus for the location where the SystemID
is equal to the PriorRA TA Record. SystemID and the EndDate/Hour is prior to the
PriorRA TARecord EndDatc/Hour and the TestResultCode is equal to "INVALID", and the number of operating
levels the OpLevelCodeList is greater than or equal to 2 or the TestClaimCode == "SLC").
if (RATATestRecordsByLocationForQAStatus is found)
Set InvalidMultiLevelRATARecord = the found record in RATATestRecordsByLocationForQAStatus.
if (PriorMultiLevelRA TA Record is not null)
Locate the most recent record in QACertificationEventRecords where the SystemID is equal to the
Prior Mu ItiL eve/RA TA Record. SystemID and RATA2Required is equal to "Y" and the QACertEventDate is either:
a) prior to the CurrentDateHour OR
b) equal to both the CurrentDateHour and the ConditionalBeginDate/Hour;
AND either:
a) QACertEventDate/Hour is after the PriorMultiLevelRATARecordEndDate/Hour OR
b) QACertEventDate/Hour is equal to the PriorMultiLevelRATARecord.EndDate/Hour AND
(TestCompletionDate is null or the TestCompletionDate/Hour is after the
PriorMultiLevelRATARecordEndDate/Hour)
AND either
a) Annual Reporting Requirement is equal to true OR
b) QACertEventDate/Hour is on or after April 1 of the year of CurrentDateHour
if {QACertificationEventRecords is found)
Set SubsequentRA TARecord = PriorMultiLevelRATARecord.
Set CurrentRataStatus = "OOC-Incomplete Recertification".
Set OverrideRataBaf = 1.0.
else
if (PriorMultiLevelRA TARecord ,Q ANccdsEvaluationFlag = "Y")
Set CurrentRATAStatus = "Prior Multi-Level RATA Not Yet Evaluated".
else if (PriorMultiLevelRATARecord TestResultCode = null or PriorMultiLevelRATARecord
.TestResultCode = "FAILED" ox PriorMultiLevelRATARecord .TestResultCode = "ABORTED")
Set CurrentRataStatus = "OOC-Incomplete QA RATA".
Set OverrideRataBaf = PriorRA TA Record. O v e ra 11B i a s A d j u s t me n t Fa c t o r.
else if (the number of levels in Prior Mu ItiL eveIRA TA Record. OpLevelCodeList is greater than or equal to
MaxLevelCount)
exit check.
else
Set CurrentRataStatus = "OOC-Incomplete QA RATA".
Environmental Protection Agency
Page 826 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Set OverrideRataBaf = fWwTf/r/M/fecwf/. Overall Bias Adjustment Factor.
if (CurrentRATAStatus is null, starts with "IC", or starts with "Undetermined" AND RATAEventOperatingLevelCount is null or
less than MaxLevelCount))
Set InvalidMultiLevelRATARecord = null.
Locate the most recent record in RATATestRecordsByLocationForQAStatus for the location where the SystemID is equal
to the QaStatusSystemld and the TestResultCode is not equal to "INVALID" and the EndDate/Hour is prior to the
Prior RA TA Record EndDatc/Hour and the number of operating levels in the OpLevelCodeList is equal to the
MaxLevelCount.
if (RATATestRecordsByLocationForQAStatus is found)
Set Prior MaxL eve/RA TA Record = the found record in RATATestRecordsByLocationForQAStatus.
Locate the most recent record in RATATestRecordsByLocationForQAStatus for the location where the SystemID
is equal to the QaStatusSystemld and the EndDate/Hour is prior to the PriorRA TA Record. E ndDatc/H our and the
EndDate/Hour is greater than the PriorMaxLevelRATARecord.EndDate/How: and the TestResultCode is equal to
"INVALID" and the number of operating levels the OpLevelCodeList is equal to the MaxLevelCount.
if (RATATestRecordsByLocationForQAStatus is found)
Set InvalidMultiLevelRATARecord = the found record in RATATestRecordsByLocationForQAStatus.
else
Locate the most recent record in RATATestRecordsByLocationForQAStatus for the location where the SystemID
is equal to the QaStatusSystemld and the EndDate/Hour is prior to the Prior RA TA Record. E ndDatc/H our and the
TestResultCode is equal to "INVALID" and the number of operating levels the OpLevelCodeList is equal to the
MaxLevelCount.
if (RATATestRecordsByLocationForQAStatus is found)
Set InvalidMultiLevelRATARecord = the found record in RATATestRecordsByLocationForQAStatus.
if (PriorMaxLevelRA TA Record is null)
Set CurrentRATAStatus = "OOC-No Prior Maximum Level RATA".
Set OverrideRataBaf = 1.0.
Locate the most recent record in QACertificationEventRecords where the SystemID is equal to the
QaStatusSystemld and
AND either
a) MaxLevelCount is equal to 2 and RATA2Required is equal to "Y" OR
b) MaxLevelCount is equal to 2 and RATA3Required is equal to "Y" OR
c) MaxLevelCount is equal to 3 and RATA3Required is equal to "Y"
AND the QACertEventDate is either:
a) prior to the CurrentDateHourOR
b) equal to both the CurrentDateHourwd the ConditionalBeginDate/Hour;
AND either:
Environmental Protection Agency
Page 827 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
a) QACertEventDate/Hour is after the PriorMaxLevelRATARecordEndDate/Hour OR
b) QACertEventDate/Hour is equal to the PriorMaxLeveIRA TARecord. EndDatc/Hour AND (TestCompletionDate
is null or the TestCompletionDate/Hour is after the Prior MaxLevelRA TA Record. EndDatc/Hour)
if (QACertificationEventRecords is found)
Set SubsequentRATARecord = Prior MaxI,eveIRA TA Record.
Set CurrentRataStatus = "OOC-Incomplete Recertification".
Set OverrideRataBaf = 1.0.
else if (Prior MaxLevelRA 7>1/?6'cwy/.Q ANeedsE\ aluationFlag = "Y")
Set CurrentRATAStatus = "Prior Maximum Level RATA Not Yet Evaluated".
else if (Prior MaxLevelRA TA Record.T cstRcsultCodc = null)
Set CurrentRATAStatus = "OOC-Prior Maximum Level RATA Has Critical Errors".
Set OverrideRataBaf = PriorRA 7>l/?6'cwY/.0\cral IB ias Adjustment Factor.
else if (PriorMaxLevelRATARecord.TesiResultCode = "FAILED")
Set CurrentRATAStatus = "OOC-Prior Maximum Level RATA Failed".
Set OverrideRataBaf = PriorRA 7>l/?6'cwY/.0\cral IB ias Adjustment Factor.
else if (PriorMaxLevelRATARecord TestResultCode = "ABORTED")
Set CurrentRATAStatus = "OOC-Prior Maximum Level RATA Aborted".
Set OverrideRataBaf = PriorRA 7>l/?6'cwY/.0\cral IB ias Adjust merit Factor.
if Prior MaxLevelRA TA Record J cstRcasonCodc = "INITIAL",
Locate the latest record in QACertificationEventRecords where
1) SystemID is equal to the QaStatusSystemld
2) QaCertEventCode is equal to "305"
3) QACertEventDate/Hour is prior to the CurrentDateHour,
if (QACertificationEventRecords is found, and the TestCompletionDate in the located record is
after PriorMaxLevelRATARecord.EndDate)
Set Prior Max I. eveIRA TA Record. Tc s t E \ p i ra t i o n D a tc = the end of the quarter twenty
quarters after the TestCompletionDate .
else
Set PriorMaxL eveIRA TA Record. Tc s t E\ p i ra t i o n D a tc = the end of the quarter twenty
quarters after the PriorMaxLevelRATARecordEndDatQ.
else
Set PriorMaxL eveIRA TA Record. Tc s t E \ p i ra t i o n Da t c = the end of the quarter twenty quarters
after the PriorMaxLevelRATARecordEndDate.
if (the date for CurrentDateHour is after the PriorMaxL eveIRA TA Record. Tc s t E \ p i ra t i o n Da tc)
if {Annual Reporting Requirement == false)
Set CurrentRATAStatus = "OOC-Prior Maximum Level RATA Expired".
Set OverrideRataBaf = PriorRA TA Record. Ovcra 11B ias Adj ust mc nt Factor.
Environmental Protection Agency
Page 828 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
else
Set GraceOpHours = RptPeriodOpHoursAccumulatorArray for the location.
If (GraceOpHours < 0)
Set CurrentRATAStatus = "Invalid Op Data".
else if (GraceOpHours > 720)
Set CurrentRATAStatus = "OOC-Prior Maximum Level RATA Expired".
Set OverrideRataBaf = PriorRA TA Record. O v c ra 11B i a s A dj u s t mc n t F ac t o r.
For each quarter beginning with the quarter after the
Prior MaxI.evetRA TA Record. Tc st E \ p i ra t i o n Da tc and continuing through the
quarter prior to the CurrentDateHour,
if (EarliestLocationReportDate <= the last day of the quarter being
checked)
Locate a record in OperatingSuppDataRecordsByLocation
where the reporting period is equal to the year/quarter being
checked and the OpTypeCode = "OPHOURS" and FuelCode is
null.
if (OperatingSuppDataRecordsByLocation is found)
Add OpValue to GraceOpHours.
if (GraceOpHours > 720)
Set CurrentRATAStatus = "OOC-Prior
Maximum Level RATA Expired".
Set OverrideRataBaf =
PriorRA TA Record. O v e ra 11B i a s A dj u s t mc n t Fa c t
or.
exit for.
else
Locate the record in ReportingFrequencyByLocation
where CalendarYear/Quarter are equal to the quarter
being checked.
if found, and (the quarter being checked is 2 or 3, or
Reporting Frequency By Location.RcporUngFrcqucncxC
ode is equal to "Q"),
Set CurrentRATAStatus = "Missing Op Data".
Set RA TAMissingOpDatalnfo = " [YEAR]
Q[QTR]" (where [YEAR] is the year of the
quarter being checked and [QTR] is the number
of the quarter being checked.)
exit for.
Results:
Result Response Severity
Environmental Protection Agency
Page 829 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Usage:
1
Process/Category:
Emissions Data Evaluation Report
C02/02 RATA Status Evaluation
2
Process/Category:
Emissions Data Evaluation Report
H20 RATA Status Evaluation
3
Process/Category:
Emissions Data Evaluation Report
H20M RATA Status Evaluation
4
Process/Category:
Emissions Data Evaluation Report
Hg RATA Status Evaluation
5
Process/Category:
Emissions Data Evaluation Report
NOX RATA Status Evaluation
6
Process/Category:
Emissions Data Evaluation Report
NOXC RATA Status Evaluation
7
Process/Category:
Emissions Data Evaluation Report
S02 RATA Status Evaluation
8
Process/Category:
Emissions Data Evaluation Report
Stack Flow RATA Status Evaluation
Environmental Protection Agency
Page 830 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: RATSTAT-7
Check Name: Determine Expiration Dates for Most Recent Prior RATA Test
Related Former Checks:
Applicability:
Description:
Specifications:
if (CurrentRATAStatus is null and Prior RA TA Record is not null and Prior RATAEventRecord is null)
Set PriorTestExpirationDate = null
Set PriorTestExpirationDate WithExtension = null
Set MissingOpData = false
Set NumberOfExtensionQuarters = 0
Set PriorTestExpirationDate = PriorRA TARecord.TcstE\pirationDatc.
Set PriorTestExpirationDateWithExtension = Prior RA TA Record. Tc s t E \ p i ra t i o n D a tc W i t h E \ tc lis i o n.
If (PriorRA 7>1/?6'cwy/.IgnorcGraccForExtcnsions is equal to 1)
Set PriorTestlgnoreGraceForExtensions = true
Else
Set PriorTestlgnoreGraceForExtensions = false
if (PriorTestExpirationDate is null)
if {Annual Reporting Requirement == false)
if (PriorRA TARecord. EndDatc is between 10/01/2007 and 12/31/2007)
Set PriorTestExpirationDate = 09/30/2008
else
Set PriorTestExpirationDate = September 30th of the year of the PriorRA TA Record. E ndDatc.
else if (QaStatusSystemDesignationCode == "B")
Locate a record in TestExtensionExemptionRecords where the SystemID is equal to the QaStatusSystemld and
the ExtensionExemptionCode is equal to "NRB720" and a ReportingPeriod equal to the CurrentReportingPeriod.
if (TestExtensionExemptionRecords is found)
Set PriorTestExpirationDate = the end of the quarter eight quarters after the PriorRA TARecord EndDatc.
if {PriorTestExpirationDate is null)
if {PriorRataIsAlternateSingleLevelRATA== true)
Set PriorTestExpirationDate = the end of the quarter one year after the
Prior MultiLevelRA TARecordlLndDate.
if (Prior Mu ItiLevelRA TA Record. G race Pc ri od I nd == 1)
Set PriorTestExpirationDate = the end of the quarter prior to the PriorTestExpirationDate.
else
if (PriorRA 7>4Rata Frequency Cd in set {4QTRS,8QTRS})
Locate the most recent QACertificationEventRecords for the PriorRA TARecord.Sy stcmID
where RATARequired is equal to "Y" and the BeginDate/Hour is prior to the
PriorRA 7>1/?6'cwy/. Bcgi nDatc/H our.
Environmental Protection Agency
Page 831 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
if (QACertificationEventRecords is found and RATACertEvent == "Y" and the
ConditionalDataBeginDate is null and the CompletionTestDate/Hour is after the
PriorRA TA Record. E ndDa te/H our)
if (PriorRA TA Record. Sy stc mTy pcCodc is in set (HCL, HF, HG, ST))
Locate the record in LocationProgramRecordsByHourLocation with the latest
EmissionsRecordingBeginDate where the ProgramCode is equal to MATS and
the EmissionsRecordingBeginDate is ON OR BEFORE the BeginDate of the
associated system in the PriorRA TA E vent Record.
If (the record in LocationProgramRecordsByHourLocation is found) and
(EmissionsRecordingBeginDate is later than
OA Certification E ventRecords. C o m p 1 c t i o nTc s t D a tc)
Set PriorTestExpirationDate = the end of the quarter one year after the
EmissionsRecordingBeginDate.
Else
Set PriorTestExpirationDate = the end of the quarter one year after the
OA CertiflcationEventRecords. CompletionT estDate.
if (PriorRA TA Record .GxnccVcnoAX nd == 1)
Set PriorTestlgnoreGraceForExtensions = true.
Else
Set PriorTestExpirationDate = the end of the quarter one year after the
OA Certification E ventRecords. C o m p 1 c t i o nTc s t D a t c.
if (PriorRA TARecord.Gn\ccPcY'\oA\nd == 1)
Set PriorTestExpirationDate = the end of the quarter prior to the
Pri orTestExpirati onDate.
if (PriorRA TA Record. Sy stc mTy pcCodc is in set (HCL, HF, HG, ST))
Locate the record in LocationProgramRecordsByHourLocation with the latest
EmissionsRecordingBeginDate where the ProgramCode is equal to MATS and
the EmissionsRecordingBeginDate is ON OR BEFORE the BeginDate of the
associated system in the PriorRA TAEventRecord.
If (the record in LocationProgramRecordsByHourLocation is found) and
(EmissionsRecordingBeginDate is later than PriorRATARecord.EndD'Mc)
Set PriorTestExpirationDate = the end of the quarter one year after the
EmissionsRecordingBeginDate.
Else
Set PriorTestExpirationDate = the end of the quarter one year after the
PriorRA 7M7tecw
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
if (PriorRA TA Record. GracePcriodI nd == 1)
Set PriorTestExpirationDate = the end of the quarter prior to the
PriorTestExpirationDate.
else
Locate the most recent QACertificationEventRecords for the Prior RA TA Record. Sy s tc m ID
where RATARequired is equal to " Y" and the BeginDate/Hour is prior to the
PriorRA TA Record. B eg i n Datc/H o u r.
if (OA Certification Event Records is found AND RATACertEvent == "Y" and the
ConditionalDataBeginDate is null and the CompletionTestDate/Hour is after the
PriorRA TA Record. EndDa te/Hour)
Set PriorTestExpirationDate = the end of the quarter two quarters after the
OA CertificationEventRecords. CompletionT estDate.
else
Set PriorTestExpirationDate = the end of the quarter two quarters after the
PriorRA TARecordEmSDntQ.
Set PriorRA TARecord J estExpirationDate = PriorTestExpirationDate.
If (PriorTestlgnoreGraceForExtensions is true)
Set PriorRA 7>1/?6'cwy/.IgnorcGraccForExtensions = 1
Else
Set PriorRA 7>1/?6'cwy/.IgnorcGraccForExtensions = 0
if (CurrentDateHour is ON OR BEFORE the PriorTestExpirationDate)
Set CurrentRATAStatus = "IC".
else if {Annual Reporting Requirement == false)
Set CurrentRATAStatus = "OOC-Expired".
if (CurrentMh vParameter == "FLOW")
Set OverrideRATABAF = ftw7L47M./te£w
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
StartQuarter = the quarter after the PriorRA TA Record. EndDatc
set EndQuarter = the quarter two years after the quarter of the PriorRA TARecord. EndDatc.
Set MaximumExtensionDate = the last date of EndQuarter
Set StartNonQaPrimaryBypassQuarter = StartQuarter
For each quarter beginning with the StartQuarter and continuing through the earlier of the quarter prior to the
quarter of the CurrentDateHour and EndQuarter
II Prevent extensions beyond the maximum expiration date
if PriorTestExpirationDate plus NumberOfExtensionQuarters + 1 is after MaximumExtensionDate,
exit loop
if (Earliest Location ReportDate > the last day of the quarter being checked)
Set NumberOfExtensionQuarters — NumberOfExtensionQuarters + 1.
Set StartNonQaPrimaryBypassQuarter = year/quarter being checked plus one quarter.
Locate a record in OperatingSuppDataRecordsByLocation where the reporting period is equal to
the year/quarter being checked and the OpTypeCode = "OPHOURS".
if (OperatingSuppDataRecordsByLocation is found AND
OperatingSuppDataRecords/iy Location.OpV'Muc < 168)
Set NumberOfExtensionQuarters — NumberOfExtensionQuarters + 1.
Set StartNonQaPrimaryBypassQuarter = year/quarter being checked plus one quarter.
else if (OaStatusSystemTypeCode begins with "S02")
Locate a record in TestExtensionExemptionRecords where the SystemID is equal to the
QaStatusSystemld and the ExtensionExemptionCode is equal to "LOWSQTR" and the
reporting period is equal to the year/quarter being checked.
if (TestExtensionExemptionRecords is found)
Set NumberOfExtensionQuarters — NumberOfExtensionQuarters + 1.
Set StartNonQaPrimaryBypassQuarter = year/quarter being checked plus one
quarter.
else if (OperatingSuppDataRecordsByLocation is not found)
Locate the record in ReportingFrequencyByLocation where
CalendarYear/Quarter are equal to the year/quarter being checked .
if found, and (the quarter being checked is 2 or 3, or
Reporting Frequency By Location.RcportingFrcqucncxCodc is equal to "Q"),
Set Missing Op Data to true.
Set RA TA Miss ing()pl) atalnfo = "[YEAR] Q[QTR]" (where [YEAR] is
the year of the quarter being checked and [QTR] is the number of the
quarter being checked.)
else if (QaStatusSystemDesignationCode == "PB")
Locate a record in TestExtensionExemptionRecords where the SystemID is equal to the
Environmental Protection Agency
Page 834 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
QaStatusSystemld and the ExtensionExemptionCode is equal to "NONQAPB" and the
reporting period is equal to the year/quarter being checked.
if (TestExtensionExemptionRecords is found)
Set NumberOfExtensionQuarters = NumberOfExtensionQuarters + 1.
Set StartNonQaPrimaryBypassQuarter = year/quarter being checked plus one
quarter.
else if (OperatingSuppDataRecordsByLocation is not found)
Locate the record in ReportingFrequencyByLocation where
CalendarYear/Quarter are equal to the year/quarter being checked .
if found, and (the quarter being checked is 2 or 3, or
ReportingFrequency/iyLocation.RcpovUngFrcqucncyCodc is equal to "Q"),
Set Missing Op Data to true.
Set RATAMissingOpDiitalnfo = "[YEAR] Q[QTR]" (where [YEAR] is
the year of the quarter being checked and [QTR] is the number of the
quarter being checked.)
else if (OperatingSuppDataRecordsByLocation is not found)
Locate the record in ReportingFrequencyByLocation where CalendarYear/Quarter are
equal to the year/quarter being checked.
if found, and (the quarter being checked is 2 or 3, or
ReportingFrequency/iyLocation.RcpovUngFrcqucncyCodc is equal to "Q"),
Set Missing Op Data to true.
Set RATAMissingOpDatalnfo = "[YEAR] Q[QTR]" (where [YEAR] is the year
of the quarter being checked and [QTR] is the number of the quarter being
checked.)
if (QaStatusSystemDesignationCode == "PB")
// Allow additional extensions for non QA Primary Bypass exemptions.
For each quarter beginning with StartNonQaPrimaryBypassQuarter and continuing through the quarter
prior to the quarter of the CurrentDateHour
Locate a record in TestExtensionExemptionRecords where the SystemID is equal to the
QaStatusSystemld and the ExtensionExemptionCode is equal to "NONQAPB" and the reporting
period is equal to the year/quarter being checked.
if {TestExtensionExemptionRecords is found)
Set NumberOfExtensionQuarters = NumberOfExtensionQuarters + 1.
else
exit loop.
Set PriorTestExpirationDateWithExtension = PriorTestExpirationDate.
Add NumberOfExtensionQuarters to PriorTestExpirationDateWithExtension.
If PriorTestExpirationDateWithExtension is greater thanMaximumExtensionDate
Set PriorTestExpirationDate WithExtension = MaximumExtensionDate
Set PriorRATARecord.TcstE\pirationDatcWithE\tcnsion = PriorTestExpirationDateWithExtension.
Environmental Protection Agency
Page 835 of 850
-------
Draft ECMPS Emissions Check Specifications 6/17/2015 12:00:00AM
else
Set PriorRA TARecord.TcstE\pi rationDatcWithE\tclision = PriorTestExpirationDate
If (CurrentDateHour is ON OR BEFORE the PriorTestExpirationDateWithExtension)
Set CurrentRATAStatus = "IC-Extension".
else if {Missing Op Data is true)
Set CurrentRATAStatus = "Missing Op Data".
Set PriorRA TA Record. Tc s t E \ p i ra t i o n D a tc W i t h E \ t c n s i o n = null
else if (RptPeriodOpTimeAccumulatorArray == -1)
Set CurrentRATAStatus = "Invalid Op Data".
else
Set GraceOpHours = RptPeriodOpHoursAccumulatorArray for the location.
if (GraceOpHours > 720)
Set CurrentRATAStatus = "OOC-Expired".
if (CurrentMh vParameter == "FLOW")
Set OverrideRA TABAF = fW yM/tecwf/.Ovcral IB ias Adjustment Factor.
else
If there are no quarters beginning with the LATER of the quarter after the
PriorTestExpirationDateWithExtension and the quarter of the EarliestLocationReportDate and ending
with the quarter prior to the CurrentDateHour,
Set CurrentRATAStatus = "IC-Grace".
else
For each quarter beginning with the quarter after the PriorTestExpirationDateWithExtension and
continuing through the quarter prior to the CurrentDateHour,
if (EarliestLocationReportDate <= the last day of the quarter being checked)
Locate a record in OperatingSuppDataRecordsByLocation where the reporting
period is equal to the year/quarter being checked and the OpTypeCode =
"OPHOURS" and FuelCode is null.
if (OperatingSuppDataRecordsByLocation is found)
Add OpValue to GraceOpHours.
if (GraceOpHours > 720)
Set CurrentRATAStatus = "OOC-Expired".
if (CurrentMh vParameter == "FLOW")
Set OverrideRATABAF =
/3/w/*/?/17>l/?6'cwY/.0\crallBiasAdjustiiicntFactor.
Environmental Protection Agency
Page 836 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
else
exit for.
Locate the record in ReportingFrequencyBy Location where
CalendarYear/Quarter are equal to the year/quarter being checked .
if found, and (the quarter being checked is 2 or 3, or
ReportingFrequency/iyLocation.RcpovUngFrcqucncyCodc is equal to
"Q"),
Set CurrentRATAStatus = 'Missing Op Data".
Set RATAMissingOpDiitalnfo = "[YEAR] Q[QTR]" (where
[YEAR] is the year of the quarter being checked and [QTR] is
the number of the quarter being checked.)
exit for.
if (CurrentRATAStatus is null)
Set CurrentRATAStatus = "IC-Grace".
If (PriorRataIsAlternateSingleLevelRATA== true AND CurrentRATAStatus = "OOC-Expired")
Set CurrentRATAStatus = "OOC-Incomplete QA RATA".
if (CurrentMh vParameter == "FLOW")
Set OverrideRATABAF = PriorRA 7>l/?6'cwY/.0\crallBiasAdjustincntFactor.
Results:
Result
Usage:
Response
Severity
1
Process/Category:
Emissions Data Evaluation Report
C02/02 RATA Status Evaluation
2
Process/Category:
Emissions Data Evaluation Report
H20 RATA Status Evaluation
3
Process/Category:
Emissions Data Evaluation Report
H20M RATA Status Evaluation
4
Process/Category:
Emissions Data Evaluation Report
Hg RATA Status Evaluation
5
Process/Category:
Emissions Data Evaluation Report
NOX RATA Status Evaluation
6
Process/Category:
Emissions Data Evaluation Report
NOXC RATA Status Evaluation
7
Process/Category:
Emissions Data Evaluation Report
S02 RATA Status Evaluation
8
Process/Category:
Emissions Data Evaluation Report
Stack Flow RATA Status Evaluation
Environmental Protection Agency
Page 837 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: RATSTAT-8
Check Name: Determine Final RATA Status
Related Former Checks:
Applicability:
Description:
Specifications:
Set AlternateRATARecord = null.
if (CurrentRATAStatus begins with "OOC")
Set InvalidRATATestNumber = null.
if (InvalidMultiLevelRATARecord is not null)
Set Invalid RATA Test Number = In validMultiL e velRA TA Record. Tc s t N u 1 lib c r
Set CurrentRATAStatus = CurrentRATAStatus &
if (CurrentMh vParameter == "FLOW")
Set RATA Status BAF = InvalidMultiLevelRA 7>4/?6'ew
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
If (/3/w/*/?/17>l£'v'6'rt?/?6'cwY/.ConditionalBcginDatc is not null)
Locate the most recent record in RATATestRecordsByLocationForQAStatus for the location
where the SystemID is in AlternateSystemlDList and the EndDate/Hour is prior to the
CurrentDateHour and the EndDate/Hour is after the
P/w/M/zlf'v'ert^ecwY/. Conditional BeginDate/Hour.
If there are multiple records found with the same begindate, prefer the record with
TestResultCode = "PASSED" or "PASSAPS", then prefer the record with TestResultCode =
"FAILED" or "ABORTED".
if (RATATestRecordsByLocationForQAStatus is found)
Set AlternateRATARecord = the found record in
RA TA TestRecordsByLocationForQAStatus.
if (AlternateRA TARecord.TcstRcsultCodc = null)
Set CurrentRATAStatus = "OOC-Prior Alternate System RATA Has Critical
Errors".
else if (AlternateRA 7>l/?6'co/Y/.TcstRcsultCodc = "FAILED")
Set CurrentRATAStatus = "OOC-Prior Alternate System RATA Failed",
else if (AlternateRA 7>l/?6'co/Y/.TcstRcsultCodc = "ABORTED")
Set CurrentRATAStatus = "OOC-Prior Alternate System RATA Aborted".
else
Locate the most recent record in RA TA TestRecordsByLocationForQAStatus for the
location where the SystemID is in AlternateSystemlDList and the EndDate/Hour is prior
to the CurrentDateHour and the EndDate/Hour is after the
Prior RA 7M£Vewf/?ectf/Y/.ConditionalBcginDatc/Hour and the QANeedsEvaluationFlag
is equal to "Y".
if (RATATestRecordsByLocationForQAStatus is found)
Set AlternateRATARecord = the found record in
RA TA TestRecordsByLocationForQAStatus.
Set CurrentRATAStatus = "Prior Alternate System RATA Not Yet Evaluated".
else if (Prior RA TA Record is not null)
Locate the most recent record in RATATestRecordsByLocationForQAStatus for the location where the
SystemID is in AlternateSystemlDList and the EndDate/Hour is prior to the CurrentDateHour and the
EndDate/Hour is after the Prior RA TA Record. EndDate/Hour.
If there are multiple records found with the same begindate, prefer the record with TestResultCode =
"PASSED" or "PASSAPS", then prefer the record with TestResultCode = "FAILED" or "ABORTED".
if (RATATestRecordsByLocationForQAStatus is found)
Set AlternateRATARecord = the found record in RATATestRecordsByLocationForQAStatus.
if (A Item ateRA TA Record. TestResultCode = null)
Environmental Protection Agency
Page 839 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Set CurrentRATAStatus = "OOC-Prior Alternate System RATA Has Critical Errors",
else if (AlternateRA 7>l/?6'cwY/.TcstRcsultCodc = "FAILED")
Set CurrentRATAStatus = "OOC-Prior Alternate System RATA Failed",
else if (AlternateRA 7>l/?6'cwY/.TcstRcsultCodc = "ABORTED")
Set CurrentRATAStatus = "OOC-Prior Alternate System RATA Aborted".
else
Locate the most recent record in RATATestRecordsByLocationForQAStatus for the location
where the SystemID is in AlternateSystemlDList and the EndDate/Hour is prior to the
CurrentDateHour and the EndDate/Hour is after the Prior RA TA Record .EndDate/Hour and the
QANeedsEvaluationFlag is equal to "Y".
if (RATATestRecordsByLocationForQAStatus is found)
Set AlternateRATARecord = the found record in
RA TA TestRecordsByLocationForQAStatus.
Set CurrentRATAStatus = "Prior Alternate System RATA Not Yet Evaluated".
If {Current RATA Status begins with "IC" or "Undetermined")
If (PriorRA TA Record is null)
Set RATA StatusBAF = 1
else if (Current RA TA Status begins with "IC-Cond", "Undetermined-Cond" or "PendingOOC-Cond" AND
(PriorRATAEventRecord QACertEventCode is in set {40, 50, 51, 100, 101, 120, 125, 151, 250, 255,
300, 305}) OR Prior RA TA Record. Te s t Re s u 11C o de does NOT begin with "PASS"))
Set RATA Status BAF = 1
else if (QaStatusSystemld is NOT equal to PriorRA TA Record. Sy stc m ID)
Locate the most recent record in RATATestRecordsByLocationForQAStatus for the location where the SystemID
is equal to the QaStatusSystemld, the TestResultCode is NOT equal to "INVALID" and the EndDate/Hour is prior
to the CurrentDateHour
If found,
Set RA TA Status BAF to the OverallBiasAdjustmentFactor in the RATA record found above.
else
Set CurrentRATAStatus to "OOC-No Prior Test or Event".
Locate the most recent record in RATATestRecordsByLocationForQAStatus for the location where the
SystemID is equal to the QaStatusSystemld, the TestResultCode is equal to "INVALID" and the
EndDate/Hour is prior to the CurrentDateHour.
If found,
Set InvalidRATATestNumber to the TestNumber in the RATA record found above.
Set CurrentRATAStatus = CurrentRATAStatus &
Set RATA Status BAF = PriorRA TA Record. O v e ra 11B i a s A dj u s t mc n t Fa c to r
Environmental Protection Agency
Page 840 of 850
-------
Draft ECMPS Emissions Check Specifications
If (CurrentRATAStatus does not begin with "IC")
Return result CurrentRATAStatus.
6/17/2015 12:00:00AM
Environmental Protection Agency
Page 841 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Results:
Result
Invalid Monitor
System
Invalid Op Data
Missing Op Data
Missing Program
OOC-Conditional
Period Expired
OOC-Conditional
Period Expired*
OOC-Event
OOC-Event*
OOC-Expired
OOC-Expired*
OOC-Incomplete
QA RATA
OOC-Incomplete
QA RATA*
OOC-Incomplete
Recertification
OOC-Incomplete
Recertification*
OOC-No Prior
Maximum Level
RATA
OOC-No Prior
Maximum Level
RATA*
OOC-No Prior
Test or Event
OOC-No Prior
Test or Event*
OOC-Prior
Alternate System
RATA Aborted
OOC-Prior
Alternate System
RATA Failed
Response
The [testtype] status for [key] could not be determined, because the Monitor System
record for MonitoringSystemID [system] has a critical error.
The [testtype] status for [key] could not be determined, because the OperatingTime in at
least one Hourly Operating Data records was missing or invalid.
The [testtype] status for [key] could not be determined, because the Op Supp Data
record for OPHOURS, OSHOURS, or OPDAYS is missing for
[MISSINGOPDATAINFO] (and possibly other previous reporting periods). If you
have submitted emissions data for prior quarters, you should be able to retrieve these
records by logging on to the EPA host.
The [testtype] status for [key] could not be determined, because a Unit Program record
associated with the initial certification event for QACertEventCode [code]
QACertEventDate [eventdate] either does not exist or has a
UnitMonitorCertificationBeginDate inconsistent with the BeginDate of the associated
Monitor System record.
The conditional data period for QACertEventCode [code] QACertEventDate
[eventdate] for SystemID [EVENTKEY] has expired.
The conditional data period for QACertEventCode [code] QACertEventDate
[eventdate] for SystemID [EVENTKEY] has expired. An invalid RATA was ignored.
You reported a QA Certification Event record for QACertEventCode [code]
QACertEventDate [eventdate] for SystemID [eventkey], but you did not indicate the
use of conditional data.
You reported a QA Certification Event record for QACertEventCode [code]
QACertEventDate [eventdate] for SystemID [eventkey], but you did not indicate the
use of conditional data. An invalid [testtype] was ignored.
The prior RATA for SystemID [RATASYS] with TestNumber [testnum] has expired.
The prior RATA for [RATASYS] with TestNumber [testnum] has expired. An invalid
prior [testtype] with TestNumber [invtestnum] was ignored.
The prior RATA for FLOW SystemID [RATASYS] with TestNumber [testnum] was a
single-level RATA instead of the required multi-level RATA. If applicable, please
review the prior single-level RATA to determine if it contained a single load flow claim
qualification record under Part 75, Appendix B, Section 2.3.1.3(c)(3)).
The prior RATA for FLOW SystemID [RATASYS] with TestNumber [testnum] was a
single-level RATA instead of the required multi-level RATA. An invalid prior test with
TestNumber [invtestnum] was ignored.
The subsequent recertification RATA for FLOW SystemID [SUBSYS] with
TestNumber [subtestnum] was performed at fewer than the required operating levels.
The subsequent recertification RATA for FLOW SystemID [SUBSYS] with
TestNumber [subtestnum] was performed at fewer than the required operating levels.
An invalid prior test with TestNumber [invtestnum] was ignored.
You did not report a valid prior [max]-level flow RATA for [key].
You did not report a valid prior [max]-level flow RATA for [key]. An invalid RATA
with TestNumber [invtestnum] was ignored.
You did not report a prior [testtype] or certification event for [key].
You did not report a valid prior [testtype] or certification event for [key]. An invalid
[testtype] with TestNumber [invtestnum] was ignored.
A prior RATA with TestNumber [alttestnum] for MonitoringSystemID [altsys] was
aborted, so [key], which contains a component that is also in the former system, is
out-cf -control.
A prior RATA with TestNumber [alttestnum] for MonitoringSystemID [altsys] failed,
so [key], which contains a component that is also in the former system, is
out-cf -control.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Environmental Protection Agency
Page 842 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
OOC-Prior
Alternate System
RATA Has
Critical Errors
OOC-Prior
Maximum Level
RATA Aborted
OOC-Prior
Maximum Level
RATA Aborted*
OOC-Prior
Maximum Level
RATA Expired
OOC-Prior
Maximum Level
RATA Expired*
OOC-Prior
Maximum Level
RATA Failed
OOC-Prior
Maximum Level
RATA Failed*
OOC-Prior
Maximum Level
RATA Has
Critical Errors
OOC-Prior
Maximum Level
RATA Has
Critical Errors*
OOC-Prior Test
Aborted
OOC-Prior Test
Aborted*
OOC-Prior Test
Failed
OOC-Prior Test
Failed*
OOC-Prior Test
Has Critical
Errors
OOC-Prior Test
Has Critical
Errors*
OOC-Recertificat
ion Test Aborted
OOC-Recertificat
ion Test
Aborted*
OOC-Recertificat
ion Test Failed
OOC-Recertificat
ion Test Failed*
OOC-Recertificat
ion Test Has
Critical Errors
OOC-Recertificat
ion Test Has
Critical Errors*
A prior RATA with TestNumber [alttestnum] for MonitoringSystemID [altsys] has Critical Error Level
critical errors, so [key], which contains a component that is also in the former system, is
out-cf-control.
The prior [max]-level flow RATA for [key] with TestNumber [maxtestnum] was
aborted.
Critical Error Level
The prior [max]-level flow RATA for [key] with TestNumber [maxtestnum] was
aborted. An invalid RATA with TestNumber [invtestnum] was ignored.
Critical Error Level
The prior [max]-level flow RATA for [key] with TestNumber [maxtestnum] has
expired.
Critical Error Level
The prior [max]-level flow RATA for [key] with TestNumber [maxtestnum] has
expired. An invalid RATA with TestNumber [invtestnum] was ignored.
Critical Error Level
The prior [max]-level flow RATA for [key] with TestNumber [maxtestnum] failed.
Critical Error Level
The prior [max]-level flow RATA for [key] with TestNumber [maxtestnum] failed. An Critical Error Level
invalid RATA with TestNumber [invtestnum] was ignored.
The prior [max]-level flow RATA for [key] with TestNumber [maxtestnum] has critical Critical Error Level
errors.
The prior [max]-level flow RATA for [key] with TestNumber [maxtestnum] has critical Critical Error Level
errors. An invalid RATA with TestNumber [invtestnum] was ignored.
The prior RATA for SystemID [RATASYS] with TestNumber [testnum] was aborted. Critical Error Level
The prior RATA for SystemID [RATASYS] with TestNumber [testnum] was aborted. Critical Error Level
An invalid prior [testtype] with TestNumber [invtestnum] was ignored.
The prior RATA for SystemID [RATASYS] with TestNumber [testnum] failed. Critical Error Level
The prior RATA for SystemID [RATASYS] with TestNumber [testnum] failed. An Critical Error Level
invalid prior [testtype] with TestNumber [invtestnum] was ignored.
The prior RATA for SystemID [RATASYS] with TestNumber [testnum] has critical Critical Error Level
errors.
The prior RATA for SystemID [RATASYS] with TestNumber [testnum] has critical Critical Error Level
errors. An invalid prior [testtype] with TestNumber [invtestnum] was ignored.
The subsequent recertification RATA for SystemID [subsys] with TestNumber
[subtestnum] was aborted.
The subsequent recertification RATA for SystemID [subsys] with TestNumber
[subtestnum] was aborted. An invalid [testtype] with TestNumber [invtestnum] was
ignored.
The subsequent recertification RATA for SystemID [subsys] with TestNumber
[subtestnum] failed.
The subsequent recertification RATA for SystemID [subsys] with TestNumber
[subtestnum] failed. An invalid [testtype] with TestNumber [invtestnum] was ignored.
The subsequent recertification RATA for SystemID [subsys] with TestNumber
[subtestnum] has critical errors.
Critical Error Level
Critical Error Level
Critical Error Level
Critical Error Level
Critical Error Level
The subsequent recertification RATA for SystemID [subsys] with TestNumber Critical Error Level
[subtestnum] has critical errors. An invalid [testtype] with TestNumber [invtestnum]
was ignored.
Environmental Protection Agency
Page 843 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Prior Alternate
System RATA
Not Yet
Evaluated
Prior Maximum
Level RATA Not
Yet Evaluated
Prior Multi-Level
RATA Not Yet
Evaluated
Prior Test Not
Yet Evaluated
Recertification
Test Not Yet
Evaluated
Undetermined-Co
nditional Data
The RATA status for [key] could not be determined, because a prior RATA with
TestNumber [alttestnum] for MonitoringSystemID [altsys], which contains a
component that is also in the former system, has not yet been evaluated.
The RATA status for [key] could not be determined, because the prior [max]-level flow
RATA with TestNumber [maxtestnum] has not yet been evaluated.
The RATA status could not be determined, because the prior multi-level flow RATA
for SystemID [RATASYS] with TestNumber [multitestnum] has not yet been
evaluated.
The RATA status could not be determined, because the applicable prior RATA for
SystemID [RATASYS] with TestNumber [testnum] has not yet been evaluated.
The RATA status could not be determined, because the subsequent recertification
RATA for SystemID [subsys] with TestNumber [subtestnum] has not yet been
evaluated.
The software could not determine if the current hour was within the conditional data
period for QACertEventCode [code] QACertEventDate [eventdate] for SystemID
[eventkey].
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Informational Message
Usage:
1
Process/Category:
Emissions Data Evaluation Report
C02/02 RATA Status Evaluation
2
Process/Category:
Emissions Data Evaluation Report
H20 RATA Status Evaluation
3
Process/Category:
Emissions Data Evaluation Report
H20M RATA Status Evaluation
4
Process/Category:
Emissions Data Evaluation Report
Hg RATA Status Evaluation
5
Process/Category:
Emissions Data Evaluation Report
NOX RATA Status Evaluation
6
Process/Category:
Emissions Data Evaluation Report
NOXC RATA Status Evaluation
7
Process/Category:
Emissions Data Evaluation Report
S02 RATA Status Evaluation
8
Process/Category:
Emissions Data Evaluation Report
Stack Flow RATA Status Evaluation
Environmental Protection Agency
Page 844 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Category:
Weekly System Integrity Status
Environmental Protection Agency
Page 845 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: WSISTAT-1
Check Name: Initialize Status Checking
Related Former Checks:
Applicability:
Description:
Specifications:
Set WsiStatus to null.
Results:
Result Response
Usage:
1 Process/Category: Emissions Data Evaluation Report
Severity
Hg System Integrity Status Evaluation
Environmental Protection Agency
Page 846 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code:
WSISTAT-2
Check Name:
Locate Prior Test
Related Former Checks:
Applicability:
Description:
Specifications:
For the WsiTestDictionary entry where the key is equal to QaStatusComponentld.
If (WsiTestDictionary entry exists)
Set WsiPriorTestRecord to null.
If (WsiPriorTestRecord is equal to null)
If (the count of days in OperatingDateArray for current location is greater than 7)
Set WsiPriorTestRecord to JFsiTes/BicftVwary.MostRecentTestRecord.
Else
Set WsiStatus to "OOC-No Prior Test".
Else
Set WsiStatus to "IC-Undetermined".
Results:
Result
Response
Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Hg System Integrity Status Evaluation
Environmental Protection Agency
Page 847 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: WSISTAT-3
Check Name: Check For Intervening Event
Related Former Checks:
Applicability:
Description:
Specifications:
Set WsilnterveningEventRecord to null.
If (WsiStatus is equal to null)
Locate the most recent record in QACertificationEventRecords where:
a) ComponentID is equal to QaStatusComponentld.
b) QaCertEventDateHour is prior to CurrentDateHour.
c) QaCertEventDateHour is after WsiPrior TestRecord. TcstDatc Hour.
d) QaCertEventCode is equal to "110" or "130"
If found
Set WsilnterveningEventRecord to the located record.
Set WsiStatus to "OOC-Event".
Else
If (WsiPriorTestRecord .TcstRcsultCodc is equal to null)
Set WsiStatus to "OOC-Test Has Critical Errors".
Else if (WsiPriorTestRecord.TestResultCode is equal to "FAILED")
Set WsiStatus to "OOC-Test Failed".
Else
For the WsiTestDictionary entry where the key is equal to QaStatusComponentld.
If {WsiTestDictionary. OperatingDateList is not null) AND (the count of days in
WsiTestDictionary.0\>QX?&mgP?&QList is greater than 7)
Set WsiStatus to "OOC-Expired".
Else
Set WsiStatus to "IC".
Results:
Result Response Severity
Usage:
1 Process/Category: Emissions Data Evaluation Report Hg System Integrity Status Evaluation
Environmental Protection Agency
Page 848 of 850
-------
Draft ECMPS Emissions Check Specifications
6/17/2015 12:00:00AM
Check Code: WSISTAT-4
Check Name: Return the Final Status
Related Former Checks:
Applicability:
Description:
Specifications:
If (WsiStatus does not begin with "IC")
return result WsiStatus.
Results:
Result
OOC-Event
OOC-Expired
OOC-No Prior
Test
OOC-Test Failed
OOC-Test Has
Critical Errors
Response
You reported a QA Certification Event record for QACertEventCode [code]
QACertEventDate [event] for [compkey], and have not yet performed the required
recertification tests.
The prior weekly system integrity test for [compkey] on [date] has expired.
You did not report a prior weekly system integrity test for [compkey] during the
reporting period. Any weekly system integrity that may have been completed in a prior
reporting period has expired.
The prior weekly system integrity test for [compkey] completed on [date] failed.
The prior weekly system integrity test for [compkey] completed on [date] has critical
errors.
Severity
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Critical Error Level 1
Usage:
1
Process/Category: Emissions Data Evaluation Report Hg System Integrity Status Evaluation
Environmental Protection Agency
Page 849 of 850
------- |