Troubleshooting Manual for Small, Facultative, Partial-Mix
Aerated, and Complete-Mix Aerated Wastewater Lagoons

Source: Jessica Duggan, EPA Region 8.

Office of Compliance
Office of Enforcement and Compliance Assurance
U.S. Environmental Protection Agency
EPA Document # 305B23001

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons


-------
Contents

Contributions and Acknowledgements	3

Abbreviations	4

Introduction	5

Manual Organization	5

1.	Manual Navigation, Impacts of Managing Change, and Financial Resources	6

IA.	Recommended Manual Navigation	6

IB.	Managing Change	7

IC.	Financial Resources	7

2.	Approach to Troubleshooting	9

3.	General Lagoon Troubleshooting Tips	10

3A.	Short-Circuiting	10

3B.	Sewage Sludge Accumulation	12

3C.	Hydraulic Overloading	13

3D. Algal Overgrowth	15

3E.	Erosion	16

3F.	Overgrown Vegetation Other Than Algae (Lagoon Surface and Banks)	18

3G. Scum and Trash Accumulation	19

3H. Low Water Levels (Leakage)	19

31.	Disinfection and Dechlorination Issues	20

4.	Facultative Lagoon Troubleshooting Tips	22

4A.	Short-Circuiting	22

4B.	Organic Overload	23

4C.	Odors	26

4D.	Algal Overgrowth	26

4E.	Inadequate Nitrification for Facilities with Ammonia Permit Limits	27

5.	Partial-Mix Aerated Lagoon Troubleshooting Tips	29

5A.	Short-Circuiting	29

5B.	Organic Overload	30

5C.	Odors	33

5D.	Algal Overgrowth	34

5E.	Inadequate Nitrification for Facilities with Ammonia Permit Limits	35

6.	Complete-Mix Aerated Lagoon Troubleshooting Tips	37

6A. Foaming	37

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons	1


-------
6B. Algal Overgrowth	38

6C. Inadequate Nitrification for Facilities with Ammonia Permit Limits	39

Appendix A. Establishing Standard Operating Parameters for Operator Observations and
Field Measurements	41

Appendix B. Establishing Standard Operating Parameters Using Laboratory Analysis	45

Bibliography	47

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

2


-------
Contributions and Acknowledgements

This report was prepared by the U.S. Environmental Protection Agency (EPA). Colleen Neely,
Cezanne Lojeski, and Rachel McAnallen edited and managed the completion of the manual. EPA
authors include Jodi Bruno, Seth Draper, Jessica Duggan, David Esparza, Chad Harsh, Seth
Heminway, Adam Howell, John Kosco, Tina Laidlaw, Damon McElroy, David Piantanida, Tess
Richman, Paul Shriner, Michael Tate, David Tobias, Barbara VanTil, and Phil Zahreddine. Ohio
Environmental Protection Agency authors include Jon van Dommelen. This report was
completed with support from Catherine Allen, Shari Barash, and Daniel Palmer.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

3


-------
Abbreviations

Table 1 presents the abbreviations used throughout the document.

Table 1. Acronyms and abbreviations.

Abbreviations

Full Phrase

BOD

biochemical oxygen demand

BODs

five-day biological oxygen demand

CBODs

five-day carbonaceous biochemical oxygen demand

CFR

Code of Federal Regulations

DO

dissolved oxygen

EPA

United States Environmental Protection Agency

l&l

infiltration and inflow

mg/L

milligrams per liter

NPDES

National Pollutant Discharge Elimination System

TSS

total suspended solids

WWTP

wastewater treatment plant

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

4


-------
Introduction

To reduce the rate of significant noncompliance with National Pollutant Discharge Elimination
System (NPDES) permits at lagoon facilities, improve water quality, and protect environmental
and public health, the U.S. Environmental Protection Agency (EPA) has developed this
troubleshooting manual. Specifically, this manual is designed to help operators at small
wastewater treatment plant (WWTP) lagoons, also called wastewater stabilization ponds,
identify causes of lagoon upset conditions and the corresponding troubleshooting steps.

This manual specifically focuses on small, facultative lagoons and partial-mix and complete-mix
aerated lagoons serving communities under 1,000 people. Additionally, while this manual
focuses on NPDES-permitted lagoons with controlled or continuous discharge, it is also relevant
to non-discharging lagoons.

Note: For more details on these and other lagoon types, review EPA's Principles of Design and
Operations of Wastewater Treatment Pond Systems for Plant Operators, Engineers, and
Managers (EPA/600/R-11/088).

Manual Organization

This manual is organized into six sections as follows:

•	Section 1 provides an overview of the recommended approach to navigating this
manual and managing lagoon changes, as well as information on financial resources.

•	Section 2 provides the steps operators should follow to identify possible lagoon upset
conditions before proceeding to the troubleshooting tips outlined in this manual.

•	Section 3 describes troubleshooting procedures applicable to all lagoon types.

•	Section 4 describes troubleshooting procedures specific to facultative lagoons.

•	Section 5 describes troubleshooting procedures specific to partial-mix aerated lagoons.

•	Section 6 describes troubleshooting procedures specific to complete-mix aerated
lagoons.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

5


-------
1. Manual Navigation, Impacts of Managing Change, and Financial
Resources

This section gives a brief overview of the recommended approach to navigating this manual and
managing lagoon changes, as well as information on financial resources.

1A. Recommended Manual Navigation

This manual includes a sample of operational problems or upsets experienced at small lagoon
systems. The troubleshooting content included in this manual is broken into four sections:

•	General lagoon troubleshooting tips.

•	Troubleshooting tips for facultative lagoons.

•	Troubleshooting tips for partial-mix aerated lagoons.

•	Troubleshooting tips for complete-mix aerated lagoons.

Table 2, below, shows the upset conditions included in each troubleshooting section of the
manual. Each upset condition section includes the following content: (1) description of upset
condition, (2) common indicators, (3) impacts, and (4) troubleshooting tips.

When experiencing an upset condition, first review the applicable general upset conditions in
Section 3. Then, review additional lagoon-specific tips in sections 4, 5, or 6. For example, if a
facultative lagoon facility is experiencing short-circuiting, first review the short-circuiting tips in
Section 3: General Lagoon Troubleshooting Tips. Then, review the additional short-circuiting
content included in Section 4: Facultative Lagoon Troubleshooting Tips.

Table 2. Manual navigation.

Section 3:
General Lagoon
Troubleshooting Tips

Section 4: Facultative

Lagoon
Troubleshooting Tips

Section 5:
Partial-Mix Aerated

Lagoon
Troubleshooting Tips

Section 6:
Complete-Mix
Aerated Lagoon
Troubleshooting
Tips

Short-Circuiting

Short-Circuiting

Short-Circuiting

Foaming

Sewage Sludge
Accumulation

Organic Overload

Organic Overload

Algal Overgrowth

Hydraulic Overloading

Odors

Odors

Inadequate
Nitrification for
Facilities with
Ammonia Permit
Limits

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

6


-------
Algal Overgrowth

Algal Overgrowth

Algal Overgrowth



Erosion

Inadequate
Nitrification for
Facilities with
Ammonia Permit
Limits

Inadequate
Nitrification for
Facilities with
Ammonia Permit
Limits

Overgrown Vegetation
Other Than Algae
(Lagoon Surface and
Banks)







Scum and Trash
Accumulation







Low Water Levels
(Leakage)







Disinfection and
Dechlorination Issues |





IB.	Managing Change

Anytime changes are made at a facility, it is critical that operators consider their potential
impacts, including those resulting from implementing troubleshooting solutions outlined in this
manual. Potential impacts include:

•	Permit requirements. Changes to the lagoon (particularly physical changes) may require
approval by a permitting or regulatory authority and/or may require design by a
licensed professional engineer. Where possible, these considerations are noted within
the manual. However, when in doubt, permitted facilities should contact their
permitting or regulatory authority with any questions.

•	Unintended impacts. Changes to lagoon design or standard operational procedures
implemented as a result of troubleshooting may result in unintended impacts elsewhere
in the lagoon. Permitted facilities should follow management of change protocols,
including documenting changes to the lagoon operating conditions, procedures, or
parameters and considering potential unintended impacts throughout the lagoon.

IC.	Financial Resources

For lagoon troubleshooting solutions beyond a facility's budget, consider grant or loan
programs offered through the federal government or other entities. At the time this manual
was completed, federal programs to consider include but are not limited to:

•	EPA's State Revolving Fund Program and Tribal Funding Sources.

•	U.S. Department of Agriculture Rural Development Program Loan and Grant Programs.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

7


-------
•	The U.S. Department of Housing and Urban Development Community Development
Block Grant Program.

Additionally, the facility may consider:

•	Contacting state or EPA permitting or regulatory authorities to learn more about
wastewater infrastructure funding or financing resources.

•	Referring to the Water Finance Clearinghouse to identify additional funding and
financing resources available for wastewater infrastructure projects.

•	Contacting a Rural. Small and Tribal Technical Assistance provider, local Environmental
Finance Center, or requesting technical assistance through EPA's Water Technical
Assistant Request Form.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

8


-------
2. Approach to Troubleshooting

If the lagoon facility is not meeting discharge requirements, first consider any feasible
operational changes. The goal of these changes should be to improve retention times, solids
removal, and lagoon hydraulics or flow patterns. After these operational changes, begin
conducting troubleshooting activities outlined in this manual.

If permit violations continue, conduct observations, field measurements, and/or lab analysis
throughout the lagoon. Operators should conduct observations, field measurements, and
analysis at the influent and effluent of each pond or cell. If there is aeration, the midway point
or both before and after any aeration should also be considered. Compare this information to
older records. Then, given observations, measurements, or sampling results, proceed to the
troubleshooting tips outlined in this manual for the system upset conditions experienced.

Note: Central to identifying when lagoons are experiencing system upset conditions is having
established and recorded standard operating parameters. Baseline data allow facilities to more
effectively identify upset conditions. They also help identify possible root causes or contributing
factors. The troubleshooting techniques described in this manual assume the facility has
baseline data to compare against data the operator has observed, measured in the field, or
analytically tested.

If baseline data are not yet established:

•	Appendix A provides a recommended inspection checklist for establishing standard
operating parameters based on operator observations and field measurements.

•	Appendix B provides an example sampling protocol for establishing standard operating
parameters based on laboratory-tested lagoon parameters.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

9


-------
3. General Lagoon Troubleshooting Tips

3A.Short-Circuiting

Short-circuiting occurs when influent passes through the lagoon, from the inlet to the outlet,
without circulating through treatment processes. Short-circuiting may lead to high biochemical
oxygen demand (BOD) and soluble BOD, moderate total suspended solids (TSS), and high
ammonia in the final cell. Short-circuiting can be most serious for lagoons with a single cell.
Operators should evaluate all cells when evaluating the presence of short-circuiting conditions,
as some may short-circuit while others may not.

Effluent that is warmer than the overall lagoon may indicate a short-circuit. To confirm this
diagnosis, conduct a dye test or add small floating objects such as oranges or tennis balls at the
influent pipe and observe the path they take. The objects may need to be added at the influent
point to each cell if the transfer pipes between cells are screened or have turtle guards. Be
mindful of any effect ambient wind may have on driving the objects. If the objects are floating
along the dike wall, rather than completing a winding path, a cell may be short-circuiting. An
additional way to identify potential short-circuiting is to compare actual detention time to
design detention time. If actual detention time is less than design detention time, this could
indicate the wastewater flow is taking a shorter path, and short-circuiting may be occurring.

Note: If the facility routinely experiences high-wind conditions, consider using a drogue or
drifter device, as shown in Figure 1. These floating devices have an underwater "sail" to catch
underwater currents when they exist. If an underwater current does exist, the operator will be
able to observe the movement of the buoy attached to the device.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

10


-------
Surface Buoy

Sensor

Tether

Sensor

Holey-Sock
- Drogue
(sea anchor)

Figure 1. Drifter device.

Short-circuiting can be exacerbated by hydraulic overloading, such as from inflow and
infiltration (l&l). If hydraulic overloading is suspected, see Section 3C.

Potential Solutions

The design and placement of influent and effluent structures is critical to avoiding short-
circuiting and loss of solids. While the options presented below may be expensive, they have
the highest probability of preventing short-circuiting in the future:

•	If the lagoon inlet is located at the center, short-circuiting can occur. Facilities should
redesign inlet and outlet structures to include manifolds and then relocate these
structures as far apart from each other as possible to avoid short-circuiting. This
redesign may require contacting a professional engineer to develop plans and getting
approval from the appropriate permitting authority.

•	If possible, add additional cells that are long and narrow. This addition will generally
require hiring an engineer to design the retrofit, receiving approval from the permitting
authority, and hiring a contractor to construct the retrofit.

•	If practicable, consider making the bottom of each cell as flat as possible and round the
corners to improve flow.

Additional solutions may be less costly than those in the previous list. However, these potential
solutions may not solve the short-circuiting. The solutions include:

•	Changing the lagoon from series operation to parallel operation (in multicell lagoons,
where feasible).

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

11


-------
•	Cleaning out weeds or accumulated solids if they affect the flow patterns.

•	In some cases, relocating mixers or aerators in a cell may improve flow distribution.

For more information, see Section 4A for facultative lagoons and
Section 5A for partial-mix aerated lagoons.

3B.Sewage Sludge Accumulation

Excess sewage sludge means less volume is available to store
wastewater and therefore reduces retention time, which can
result in poor treatment. Common indicators of sewage sludge
accumulation include high BOD, low-to-moderate TSS, low
dissolved oxygen (DO), and high ammonia in the final cell.

To diagnose sewage sludge accumulation, check for buildup at the
inlet and outlet points, tanks, ultraviolet channels, pipes, or
anywhere sewage sludge may accumulate. As an example, Image
1 shows sludge accumulating at a transfer structure. Next,
measure sewage sludge depth in the lagoon using a core sampler,
sonar, or sewage sludge interface detector at 24 to 36 sample points throughout each ceil,
depending on the number of cells in the system. After collecting measurements, calculate the
average sewage sludge depth to estimate overall sewage sludge accumulation. If the sewage
sludge depth is at or above 25 percent of the lagoon operating depth, the lagoon requires de-
sludging.

Example: A facultative lagoon with a typical operating depth of 60 inches (5 feet) should be de-
sludged when the average sewage sludge depth meets or exceeds 15 inches (i.e., 25 percent of
60 inches).

Potential Solutions

A short-term solution to sewage sludge accumulation is to use a vacuum truck or trash pump to
remove accumulated sewage sludge from conveyance structures. Depending on available
equipment, an operator may also consider fitting a power takeoff pump on a tractor or
commercial vehicle to pump out sewage sludge. Other tools an operator may consider include
chain drags, nets, or rakes.

If sludge accumulation is causing problems (e.g., high soluble BOD), increase aeration as a
temporary solution and plan to remove sludge from the bottom of the lagoon in accordance
with local regulations.

Source: EPA.

Image 1. Sludge accumulation
at a transfer structure.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

12


-------
Options for sewage sludge waste management include:

•	Land application as fertilizer or soil conditioner, meeting the requirements of 40 Code of
Federal Regulations (CFR) Part 503.

p Note: This management method is typically part of the facility discharge permit.
However, the facility may need to obtain an additional permit depending on the
specific sewage sludge reuse scenario.

•	Surface disposal, meeting the requirements of 40 CFR Part 503.

•	A landfill, meeting the requirements of 40 CFR Part 258.

•	Incineration, meeting the requirements of 40 CFR Part 503

3C. Hydraulic Overloading

Hydraulic overloading occurs when increased flow (e.g., from population growth) or l&l exceed
lagoon design flow capacity. Hydraulic overloading shortens water retention time and degrades
performance.

As depicted in Figure 2 below, inflow is water that enters a sewer system through a specific
path, such as manhole covers, roof leaders, cellar drains, yard drains, area drains, drains from
wet areas, cross-connections between storm sewers and sanitary sewers, catch basins, or
cooling towers. Infiltration is water that can seep into the collection system through broken
sewage pipes or faulty joints.

Figure 2. Infiltration and inflow.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

13


-------
Note: Hydraulic overloading can also be caused by sewage sludge accumulation, which can
reduce available lagoon volume. If the overloading may be due to sewage sludge accumulation,
refer to Section 3B.

If water levels in the lagoon exceed the design depth (e.g., reduced freeboard) for an extended
period, or the lagoon is frequently overloaded during rainfall events, the lagoon may be
experiencing hydraulic overloading.

Comparing the actual (i.e., measured) detention time with the lagoon's designed detention
time can help confirm hydraulic overloading due to increased flow or l&l. If the measured
detention time is less than the designed detention time, the lagoon is hydraulically
overloaded.

Note: To calculate the actual detention time, measure the influent rate using a flow meter and
divide this value by the total lagoon volume. Then, compare this measured detention time
against the lagoon's designed detention time.

Potential Solutions

If resources allow, consider contacting a technical assistance provider or a professional
engineer to perform an l&l study.

If l&l studies are not accessible, facilities may monitor for common indicators of an l&l problem
such as significant spikes in inflow during a wet weather event, high groundwater conditions, or
lift stations that run for a longer period after a rain event. Additionally, systems may consider
utilizing a 2014 EPA Guide for Estimating Infiltration and Inflow for additional means of
identifying l&l.

If inflow is discovered, cap or seal the open access points contributing to inflow. Repair
manholes by grouting and/or repairing the frames and covers.

If sources of infiltration are discovered, consider repairing damaged pipes that are contributing
to infiltration through trenchless rehabilitation or an open-cut replacement, as appropriate.

Note: Become familiar with the sewer use ordinance that gives municipalities legal standing to
prohibit illegal sources of l&l.

If correcting l&l does not resolve the hydraulic overloading, consider constructing an additional
lagoon cell. Resolving hydraulic overloading via construction may be necessary to meet effluent
limits.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

14


-------
3D. Algal Overgrowth

Algal overgrowth, such as that depicted in Image 2, is prevalent in
regions with a high number of sunny days during the year,

Overgrowth occurs predominantly in the spring and summer. Long
detention times, shallow pond depths, abundant nutrients, warm
water, and sunshine promote algal growth. Algal overgrowth
increases water pH, consumes oxygen (deficits are measurable at
night when photosynthesis is absent), and can lead to high TSS
levels. Ammonia increases in toxicity when pH is elevated, meaning
the same amount of ammonia is more toxic. This condition may
cause fish kills in the water body receiving lagoon discharge.

Algal overgrowth may increase effluent BOD under certain
conditions. Effluent from some types of lagoons contains algae and
may require additional treatment or "polishing" to meet discharge
permit requirements.

Algae consume carbon dioxide in sunlight, which raises pH levels. Consequently, high effluent
pH (greater than 9.0) can be a sign of algal overgrowth. Operators can also determine algal
overgrowth by examining effluent microscopically and observing elevated algae content.

Potential Solutions

To suppress algae growth and reduce solids in effluent discharges:

•	Add water-soluble dye that blocks sunlight.

•	Add a floating cover, such as floating ballast balls or a swimming pool cover. Installing a
lagoon cover may require assistance from an engineer,

b Note: The pool cover should not cover the entire lagoon.

•	Add mechanical aeration and mixing to a lagoon to help control algae overgrowth.
Mechanical aeration can cause turbulent surface water to block sunlight penetration.
Recirculating wastewater in the final cell may help stifle algae growth before an algae
bloom sets in, but this should be done carefully so as not to adversely impact settling
where needed. If the lagoon is not currently discharging, mixing the lagoon for a month
prior to discharge can be effective to address algae overgrowth.

•	For a multicell aerated lagoon system, consider removing an individual cell from
operation to reduce the overall hydraulic retention time and prevent or address an algal
overgrowth condition. However, make sure the reduction in retention time does not
negatively affect treatment.

Source: EPA.

Image 2. Yellow-colored
algae growth.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

15


-------
•	If considerable sewage sludge accumulation exists, de-sludge the lagoon.

•	If permitted to discharge, discharge effluent that is below the surface at variable depths
to reduce surface algae entering the effluent. Take care not to discharge effluent from
too far below the surface, or sewage sludge may inadvertently be drawn out with the
effluent.

•	For multicell lagoon systems, consider operating cells in series (e.g., effluent flows
through each cell in succession), provided that operating in series does not affect overall
lagoon operations.

•	If available, and in coordination with the relevant regulatory authority, use a small final
lagoon that has a one-day to two-day hydraulic detention time.

For additional algal overgrowth troubleshooting solutions, refer to Section 4D for facultative
lagoons, Section 5D for partial-mix aerated lagoons, and Section 6B for complete-mix aerated
lagoons.

3E. Erosion

Erosion can be a common problem for lagoon systems, specifically for the interior slopes,
where erosion can reduce the structural effectiveness of banks and dikes constructed to
contain process water. Disintegration of the soils and materials that compose the interior
slopes is primarily caused by lagoon wave action and surface runoff. Wave action mechanisms
occur at the interface of lagoon water and the surrounding interior slopes, while surface runoff
occurs when particles detach from and transport off the slopes.

Other factors that can contribute to erosion include burrowing animals and deteriorated or
inappropriately constructed erosion control features (e.g., protection systems at pipe locations,
riprap, geotextile fabric, liners, topsoil with established growth).

Operators should first determine the primary erosion mechanism and review the lagoon system
design, but the primary objective of erosion control should be to protect the interior slopes.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

16


-------
Potential Solutions

Source: EPA.

Image 3. Riprap dike construction.

Install riprap, such as the riprap
depicted in Image 3, or a concrete
liner along banks to prevent erosion.

If riprap is not available, gunite (also
known as shotcrete or sprayed
concrete) may be an option. Be sure
the liner, or sprayed concrete,
extends from the lagoon banks to 3
feet below the surface of the water.

This depth will help deter muskrats
and protect against erosion from
strong wave action. Contact the

appropriate regulatory authority to discuss any regulatory requirements prior to lining
dikes.

Consider adding fast-growing grass cover with a shallow and dense root system. Avoid
long-rooted plants that can cause leakage or damage to other structural elements.

Control burrowing animals such as muskrats with the following methods:

b Maintain fencing around the lagoon to discourage rodents.

b Remove food supply such as cattails and burr reed. See Section 3F for more
information.

>	Raise and lower the water level by 6 to 8 inches over several weeks, which
upsets the muskrats' environment and makes them vulnerable to predators.

>	If the problem persists, check with the local regulatory authorities for approved
methods of removing burrowing animals.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

17


-------
3F. Overgrown Vegetation Other Than Algae (Lagoon Surface and Banks)

Excessive weed growth on lagoon banks,
such as that in Image 4, can harbor insects,
attract vermin and snakes, and trap grease
and organics. Weeds can also interfere with
wind movement, provide habitat for
burrowing animals, cause odors, create
breeding conditions for mosquitoes, cause
short-circuiting problems, and allow scum to
collect in the lagoon.

On the lagoon surface, duckweed and other
vegetation stop sunlight penetration and
prevent wind movement, thus reducing
oxygen in the lagoon. Root penetration through the bottom of the dike can cause leaks in the
lagoon seal. Woody vegetation, such as trees and shrubs, should never grow on lagoon dikes.

Note: Unless duckweed is specifically introduced to create shade and control algal growth, skim
the surface regularly and do not allow it or other vegetation to accumulate. Otherwise,
duckweed can cause sewage sludge accumulation, low DO, and odors.

Potential Solutions

Implement control measures when vegetation becomes excessive.

For lagoon banks:

•	Mow grass periodically and control weed growth along the edges of lagoon cells,
including pulling new growth of cattails and bulrushes.

•	Cut and remove trees, shrubs, and dead vegetation on dikes and at the edges of lagoon
cells.

•	As a last resort, if the lagoon or dikes have excessive vegetation that can only be
remedied by herbicides, contact a licensed herbicide applicator to apply herbicide
according to the label restrictions. Failure to do so may result in harm to the beneficial
biological activity in the lagoon and failure to meet permit limits.

For the lagoon surface:

•	Use a boat to push and collect vegetation in the corner of a lagoon cell, or take
advantage of a windy day, then remove the collected vegetation with a rake or a
vacuum truck.

Source: EPA.

image 4. Partially cleared, overgrown vegetation.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

18


-------
3G. Scum and Trash Accumulation

Both scum and trash accumulation can be problematic for lagoons, preventing sunlight
penetration and wind movement, as well as reducing DO concentration. These conditions can
lead to odors and provide a habitat for insects.

Note: A small amount of scum may not be cause for concern. However, scum covering a
significant portion of a lagoon cell will require intervention.

Potential Solutions

Inspect the lagoon surface and the inlet and outlet structures for scum buildup on a weekly
basis. Clean the structures regularly to remove floating debris, caked scum, or trash.

To remove excessive scum and trash:

•	Use rakes, a portable pump that can create a water jet, or motorboats to break up scum
formations. Scum usually sinks once it is broken up. If scum remains, skim and properly
dispose of the removed scum. Facilities should coordinate with state regulatory
agencies regarding potential options and related regulatory requirements for handling
scum, including potential recycling opportunities.

•	If the influent regularly contains excessive fats, oils, and greases, review local sewer use
ordinances and implement a fats, oils, and greases program that requires installing
grease interceptors at commercial (e.g., a restaurant) and industrial facilities.

•	Add pretreatment (e.g., skimming, floating booms, sorbent pads) to prevent scum
buildup in the future.

•	If trash accumulates in the primary treatment cell, consider modifying the influent
structure to screen it out. This process may require approval from the permitting
authority; consider applicable design standards in making modifications.

•	Add a channel in the headworks at an appropriate flow velocity (between 15-30
centimeters per second) to settle sand and grit particles before they enter the lagoon
and contribute to scum and trash buildup. Always properly dispose of built-up grit.

•	Study wind directions and locate transfer outlets to prevent dead pockets where scum
tends to accumulate. Retrofits may need approval from the permitting authority and
should be designed by a professional engineer.

3H. Low Water Levels (Leakage)

Lagoons can leak due to excessive vegetation, erosion caused by burrowing animals, or leaks in
the lagoon lining, seals, or control structures. Leakage can cause low water levels, increased
vegetation, and potential groundwater infiltration or permit violations.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

19


-------
Note: Some states have requirements for lagoons that include maximum seepage, leakage
tolerance, and/or leak detection.

If leakage is suspected, consider conducting water balance testing by determining the
difference between recorded inflows (i.e., sewage and rainfall) and outflows (i.e., seepage,
discharge, irrigation, and evaporation). In arid and semi-arid parts of the country, evaporation
will exceed rainfall, so be sure to factor evaporation in the "outflow" calculation. If outflows
exceed inflows, further investigation may be required to determine potential sources of
leakage.

Note: For resources on water balance testing, refer to the Oregon Department of
Environmental Quality's Guidelines for Estimating Leakage from Existing Sewage Lagoons or, if
possible, contact a technical service provider to assist with testing.

Potential Solutions

To address leakage, inspect control structures and lagoon lining for breaches and repair as
necessary. Many states have protocols for inspecting and repairing leaking lagoons. Check with
the state government for inspection or repair protocols if support is needed.

If leakage is due to erosion or burrowing animals, refer to Section 3E and Section 3F,
respectively, for additional troubleshooting information.

31. Disinfection and Dechlorination Issues

The last steps in treating wastewater can include disinfection1 to kill pathogenic organisms and
dechlorination to remove chlorine residuals generated from chlorine disinfection before
effluent is discharged.

Improper or incomplete disinfection and dechlorination can result in excess coliform. Coliform
can form for several reasons, including poor chlorine contact chamber design or an increase in
chlorine-demanding substances such as hydrogen sulfide, dead algae, organic matter, or
waterfowl contamination.

Note: When using chlorine to disinfect, chlorination must be followed by dechlorination prior
to effluent discharge. This step protects fish and other aquatic life in receiving waters from the
toxic nature of chlorine, even at low levels. Additionally, dechlorination dosing and retention
times should follow state requirements.

1 The most common disinfection methods are chlorination (with gas or liquid) or exposure to ultraviolet light.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

20


-------
Potential Solutions

To address the potential causes improper or incomplete disinfection and dechlorination, begin
by inspecting the chlorine contact chamber for buildup of solids. If buildup is present, remove
the buildup with available tools.

Next, test the chlorine residual to determine whether to increase the chlorine feed rate. A
chlorine residual test, also called a CI- test, determines the amount of chlorine present after
disinfection. Grab samples must be tested immediately and cannot be held for analysis.

Note: To help prevent inaccurate chlorine residual readings, ensure the sample is not exposed
to sunlight or agitation, and that the sample collection bottle is clean. These issues can cause an
inaccurate (generally low) reading.

Note: Maintaining sufficient chlorine residual in accordance with NPDES permit requirements is
important for complying with coliform requirements in the facility's NPDES permit. However,
NPDES permits can also include limits on chlorine residuals in effluent. To avoid permit
violations, take chlorine residual samples to determine when the residual is low enough to
discharge, per the facility's NPDES permit.

If using a tablet feeder in a small lagoon for chlorine disinfectant, be aware that if the tablets
are used up and fully dissolved, no chlorine will be available to disinfect the effluent. Likewise, if
the dechlorinator runs out of dechlorination tablets, then the effluent may contain harmful
concentrations of chlorine in the effluent. At times, the chlorine and dechlorination tablets can
become trapped in the dispensing tube and therefore do not fall down into the flow entering
the contact tank. When this happens, it is possible no chlorination or dechlorination will occur,
which would likely result in a permit violation for chlorination. The tablets must be properly
inserted into the tubes so that when one tablet dissolves, the next tablet falls into the correct
place.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

21


-------
4. Facultative Lagoon Troubleshooting Tips

A facultative lagoon, also known as a photosynthetic pond, is not mechanically mixed or
aerated. As depicted in Figure 3 below, facultative lagoons have an aerobic layer, followed by
an anoxic or facultative layer, and then an anaerobic layer beneath. The aerobic layer at the top
is caused by atmospheric reaeration and algal photosynthesis, which supports aerobic and
facultative bacteria.

Evaporation

Aerobic

Bacteria

Anaerobic
Bacteria

Wastewater

Settled Solids

Sunlight

ig-L

Air Movement ¦

Figure 3. Facultative lagoon.

Some unique features of facultative lagoons include:

•	Most facultative lagoons operate without primary treatment.

•	Facultative lagoons may be unable to discharge during the winter due to ice and low
oxygenation and fermentation, which can slow and impede treatment.

•	Facultative lagoon layers may invert in the spring and fall when temperature
fluctuations make the surface water layer more dense than lower layers. When the
heavier water sinks, it creates instability, turbidity, and odors.

4A.Short-Circuiting

Short-circuiting occurs when influent passes from the inlet to the outlet of the lagoon without
circulating through treatment processes. Short-circuiting is more likely during the winter
months when temperature stratification is more likely. Temperature stratification can cause
short-circuiting when the influent water temperature is much higher than the lagoon
temperature and flows over the lower layers without mixing.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

22


-------
Short-circuiting may lead to high BOD and soluble BOD, moderate TSS, and high ammonia in the
final cell. Short-circuiting can be most serious for lagoons with a single cell. Operators should
evaluate all cells when evaluating the presence of short-circuiting conditions, as some may
short-circuit while others may not.

Effluent that is warmer than the overall lagoon may be an indicator of a short-circuit. To
confirm this diagnosis, conduct a dye test or add small floating objects such as oranges or tennis
balls at the influent pipe and observe the path they take. The objects may need to be added at
the influent point to each cell if the transfer pipes between cells are screened or have turtle
guards. Be mindful of any effect ambient wind may have on driving the objects. If the objects
are floating along the dike wall, rather than completing a winding path, a cell may be short-
circuiting. An additional way to identify potential short-circuiting is to compare actual detention
time to design detention time. If actual detention time is less than design detention time, this
could indicate the wastewater flow is taking a shorter path, and short-circuiting may be
occurring.

Note: If the facility routinely experiences high-wind conditions, consider using a drogue or
drifter device, as shown in Figure 1. These floating devices have an underwater "sail" to catch
underwater currents when they exist. If an underwater current does exist, the operator will be
able to observe the movement of a buoy attached to the device.

Short-circuiting can be exacerbated by hydraulic overloading, such as from l&l. If hydraulic
overloading is suspected, see Section 3C.

Potential Solutions

In addition to the potential solutions listed within Section 3A, consider these additional
potential solutions, specific to facultative lagoons:

•	Add baffles, curtains, or other engineered barriers along the width of the cell to redirect
flow and enhance turbulence and mixing.

•	Install a manifold at the cell inlet to distribute the hydraulic load more evenly across the
cell.

4B. Organic Overload

Organic overloading occurs when a lagoon is receiving more organic material than it was
designed to receive. In small rural communities, food processing entities such as small animal
slaughtering and dairy operations can contribute to a significant organic load. Additional causes
can include expanding the service area without increasing the capacity of the lagoon, as well as
poor lagoon design.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

23


-------
The layer of water near the surface of a facultative lagoon generally contains sufficient DO from
atmospheric aeration and photosynthetic oxygenation to support the growth of aerobic and
facultative bacteria that oxidize and stabilize wastewater organics. However, when a lagoon is
organically overloaded, DO levels drop as organic material consumes more oxygen to meet an
increase in BOD.

When DO levels drop, phi falls, ammonia levels
increase, effluent has high BOD, and odors may
be present. Color changes, such as the lagoon
water in Image 5, may also indicate overloading.

For example, facultative lagoons are commonly
emerald green but may change to gray, brown,
black, pink, or red when experiencing organic
overloading.

As a starting point to monitor DO levels, measure
DO at the effluent discharge point of each lagoon
cell. If a DO meter and boat are available, measure oxygen in the upper photic zone at different
locations throughout the lagoon system to get a better idea of the lagoon's condition.
Generally, the average DO content in the upper photic zones should be approximately 2.0
milligrams per liter (mg/L), with 1 mg/L or below (or a pH level below 6.5) indicating conditions
requiring intervention.

Note: Levels of DO vary throughout the day and night. For this reason, it is best to establish
baseline measurements for different periods throughout the day and night.

Potential Solutions

There are multiple ways to address organic overloading, including reducing organic matter in
the influent or making adjustments to the lagoon that can support increased DO concentration
and thus handle an increased organic load.

Other solutions include:

• if the lagoon receives industrial or commercial wastewater, consider asking these
facilities to improve housekeeping procedures (e.g., reduce spills, clean up raw feed
materials near floor drains, install grease traps). Alternatively, the lagoon WWTP can
consider implementing pretreatment programs.2

2 The National Pretreatment Program is a Clean Water Act regulatory program designed to control pollution
emitted from indirect dischargers, which are often commercial or industrial users that send their waste to a direct

Source: Jessica Duggan, EPA Region 8.

Image 5. Brownish-red lagoon water.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

24


-------
•	Remove weeds such as duckweed if they cover more than 40 percent of the lagoon.
Removing excess weeds on the surface of the lagoon can increase DO content.

•	If there is evidence of excess sewage sludge accumulation that is causing organic
overloading beyond lagoon design, de-sludge the affected cells to increase DO (see
Section 3B).

•	If the lagoon is operated in series (e.g., flow goes through each cell in successions),
consider converting to operating in parallel (e.g., more than one cell that is receiving
wastewater at the same stage of treatment). See Figure 4 for examples of both
methods. Splitting influent flow between two cells reduces the effective load. However,
the lagoon design and actual hydraulic loading may make this impossible since a single
cell does not provide sufficient treatment in many cases. Consult the permitting
authority and a professional engineer when considering changing the cell structure.

Influent

Effluent

Cells in Series

Influent

Effluent

Cells in Parallel

Figure 4. Parallel and series cell operations.

discharger (i.e., NPDES permitholder) like a WWTP. It is always good operational practice to require industries to
institute pollution prevention practices in their facilities to minimize impacts on a lagoon system. This practice
becomes imperative if a lagoon is consistently experiencing organic overloading, pass-through, or interference. The
operator may need to require industrial users in their community to pretreat their waste before sending it to the
lagoon. Learn more about the National Pretreatment Program.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

25


-------
4C. Odors

Aerobic treatment processes in the upper layer of facultative lagoons generally control odors
produced by the lower anaerobic layers. However, during seasonal inversion, odorous
compounds are released into the air and may become a public nuisance. These odors are
typically temporary.

Odors can also be caused by low DO. When DO is low, the contents might be septic. In most
cases, wastewater odors result from anaerobic or septic conditions with no DO available for
microbial respiration. As a result, sulfate-reducing bacteria utilize the sulfate for respiration and
produce malodorous hydrogen sulfide, which has low solubility in the wastewater and is
characterized by a strong rotten egg odor released to the atmosphere. Other odorous organic
compounds such as mercaptans and amines may also be present and released.

Odors and low DO could also be caused by short-circuiting, as well as poor wind action in
facultative ponds due to trees, resulting in anaerobic conditions and low pH in certain areas.

Note: If multiple cells exist, use a DO probe to identify which cell is causing the odor.

If algal overgrowth is the suspected cause of the odor, see Section 4D.

Potential Solutions

•	Reduce organic overload if possible (see Section 4B for details).

•	If a multicell lagoon is operated in series and there is organic overload, consider
converting to operating in parallel by splitting influent flow between the first two cells,
thereby reducing the loading rate on the first cell. The lagoon design and actual
hydraulic loading may make operating in parallel impossible since a single cell might not
provide sufficient treatment in many cases. Consult the permitting authority and a
professional engineer when considering changing the cell structure.

•	Mitigate odor with sodium nitrate to increase DO.

4D. Algal Overgrowth

Algae in the aerobic and facultative zones is essential to the proper functioning of a facultative
treatment lagoon. It produces oxygen necessary for aerobic bacteria, which break down the
organic waste compounds in sewage. However, excessive algae growth can lead to high TSS and
BOD concentration in the effluent and contribute to turbidity.

Overgrowth typically occurs in the spring and summer during extended exposure to higher
temperatures and sunlight. Algae consume carbon dioxide during sunlight, which raises pH
levels. Consequently, high effluent pH (greater than 9.0) can be a sign of algal overgrowth. The

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

26


-------
presence of algal overgrowth may also be determined by examining effluent microscopically
and observing elevated algae content.

Effluent from some types of lagoons may require additional treatment or "polishing" to meet
discharge permit requirements.

Potential Solutions

In addition to the potential solutions listed within Section 3D, consider these additional
potential solutions, specific to facultative lagoons:

•	If permitted, discharge effluent that is below the surface at variable depths to reduce
the amount of surface algae that enters the effluent. However, take care not to draw
effluent from too low in the lagoon or sewage sludge may be drawn inadvertently.

•	Consider blocking sunlight with a cover in areas with algae areas or on the last settling
cell in a multicell lagoon, which will prevent new algae growth and cause existing algae
to die off and settle to the bottom. As a last option, consider using chemical additives in
accordance with EPA registry instructions provided they do not negatively impact
effluent quality.

•	If the algal overgrowth is caused by excessive hydraulic retention time in a multicell
lagoon, consider temporarily removing an individual cell from operation, if possible, to
reduce the overall hydraulic retention time and prevent algal overgrowth conditions.

4E. Inadequate Nitrification for Facilities with Ammonia Permit Limits

Nitrification is a biological process involving a group of aerobic organisms referred to as
nitrifiers that oxidize ammonia to nitrite and then to nitrate. This process occurs under aerobic
conditions, sufficient alkalinity, a favorable temperature, and other conditions such as a
sufficient detention time for the nitrifiers, suspension of nitrifiers for contact with ammonia and
nitrite, and an adequate DO concentration (typically maintained at a minimum of 2 mg/L).
Alkalinity levels above 60 mg/L of calcium carbonate are required to maintain nitrification and
depend on pH and concentrations of ammonium nitrogen. Nitrifiers are slow growers and more
sensitive to environmental factors than compounds that remove BOD. As such, for facilities that
rely on nitrification to meet discharge permit limits for ammonia, maintaining such favorable
conditions is important. Otherwise, effluent ammonia concentration can exceed permit limits.

Providing enough oxygen to meet both the BOD and ammonia removal demand is important
for nitrification. Depending on lagoon design and the ammonia effluent limit, this may involve
lagoon modifications requiring the services of a consultant and approval of the permitting
authority.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

27


-------
Nitrification generally occurs over a wastewater temperature range of 4-45 °C (39-113 °F), with
35-42 °C (95-108 °F) being the optimum range. Many facultative lagoons in colder climates are
not capable of implementing sufficient operational upgrades and are required to store
wastewater and not discharge during winter periods.

Potential Solutions

Identify what may be causing partial or low nitrification (e.g., poor ammonia removal), then
consider one of the following potential solutions depending on the cause:

•	Check for increases in BOD and ammonia loading to the lagoon and consider whether
options are available to reduce the loadings to the lagoon. In some cases, running
lagoons in parallel instead of in series may be a temporary option until the loadings are
reduced, provided adequate retention time is available. Such changes may need
approval from the permitting authority.

•	If there is considerable sewage sludge accumulation, de-sludge the affected cell (see
Section 3B).

•	Increase the DO content mechanically by removing anything blocking atmospheric
reaeration and algal photosynthesis in sunlight. This process may include removing
excessive duckweed, matted algae, or sewage sludge that is blocking the surface.

•	Supplement alkalinity by adding lime, using the facility's standard operating procedures
specific to the lagoon design and dimensions.

•	If short-circuiting is suspected, consider adding baffles to better control flow and
improve hydraulic retention time.

•	If necessary, consider conducting an engineering study of feasible options for upgrading
the lagoon facility for consistent ammonia removal.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

28


-------
5. Partial-Mix Aerated Lagoon Troubleshooting Tips

In aerated lagoons, such as the one
depicted in Image 6, oxygen is supplied
primarily through mechanical (i.e. surface)
or diffused aeration, rather than by algal
photosynthesis. Partial-mix aerated
lagoons provide enough aeration to meet
the oxygen requirements of the system
and provide partial mixing of the lagoon.

Some partial-mix aerated lagoons were
originally facultative and eventually
needed aerators to meet discharge
requirements. Aerated lagoons can usually
discharge throughout the winter, while an ice-covered facultative lagoon may not be able to do
so. Overall, aerated lagoons need less land area than facultative lagoons and can provide a
more consistent level of treatment.

A common modification to aerated lagoons is using plastic curtains with floats anchored to the
bottom of the dike to divide existing lagoons into multiple cells and/or serve as baffles to
improve hydraulic conditions. Another modification is to install a row of submerged d iff users—
suspended from flexible, floating booms—that cause the wastewater to move in a cyclical
pattern.

5A.Short-Circuiting

Short-circuiting occurs when influent passes through the lagoon, from the inlet to outlet,
without properly circulating through treatment processes. Short-circuiting is more likely during
the winter months when temperature stratification is more iikely. Temperature stratification
can cause short-circuiting when the influent water temperature is much higher than the lagoon
temperature and flows over the lower layers without mixing. Additionally, in partial-mix
aerated lagoons, if aerators are cycled on and off, short-circuiting is more likely to occur when
aerators are cycled off.3 It's recommended to aerate lagoons at night when there is no sunlight
to support algae growth.

3 During the day, when light allows for photosynthesis by algae, aerators can be cycled off. If aerators are left on
during the day, the lagoon may be "off-gassing" essential oxygen.

Source: EPA.

Image 6. Wind-driven aerators on a lagoon.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

29


-------
Short-circuiting may lead to high BOD and soluble BOD, moderate TSS, and high ammonia in the
final cell. Short-circuiting can be most serious for lagoons with a single cell. Operators should
evaluate all cells when evaluating the presence of short-circuiting conditions, as some may
short-circuit while others may not.

Effluent that is warmer than the overall lagoon may be an indicator of a short-circuit. To
confirm this diagnosis, conduct a dye test or add small floating objects such as oranges or tennis
balls at the influent pipe and observe the path they take. The objects may need to be added at
the influent point to each cell if the transfer pipes between cells are screened or have turtle
guards. Be mindful of any effect ambient wind may have on driving the objects. If the objects
are floating along the dike wall, rather than completing a winding path, a cell may be short-
circuiting. An additional way to identify potential short-circuiting is to compare actual detention
time to design detention time. If actual detention time is less than design detention time, this
could indicate the wastewater flow is taking a shorter path, and short-circuiting may be
occurring.

Note: If the facility routinely experiences high-wind conditions, consider using a drogue or
drifter device, as shown in Figure 1. These floating devices have an underwater "sail" to catch
underwater currents when they exist. If an underwater current does exist, the operator will be
able to observe the movement of a buoy attached to the device.

Short-circuiting can be exacerbated by hydraulic overloading, such as from l&l. If hydraulic
overloading is suspected, see Section 3C.

Potential Solutions

In addition to the potential solutions listed in Section 3A, consider these additional potential
solutions, specific to aerated lagoons:

•	Relocate aerators to promote a flow path that moves through the lagoon rather than
adhering to the dike wall. Baffles and manifolds can be added to break up the flow path.

•	Add directional aerators or mixers.

•	If the lagoon has appropriate pumping and piping equipment, recirculate effluent using
portable pumps to encourage mixing.

5B.Organic Overload

Organic overloading occurs when the lagoon is receiving more organic material than it was
designed to receive. In small rural communities, food processing entities such as small animal
slaughtering and dairy operations can contribute to a significant organic load. Additional causes

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

30


-------
can include expanding the service area without increasing the capacity of the lagoon, as well as
poor lagoon design.

The layer of water near the surface of a facultative lagoon generally contains sufficient DO from
atmospheric aeration and photosynthetic oxygenation to support the growth of aerobic and
facultative bacteria that oxidize and stabilize wastewater organics. However, when a lagoon is
organically overloaded, DO levels drop as more oxygen is consumed by organic material to
meet an increase in BOD.

When DO levels drop, pH falls, ammonia levels increase, effluent has high BOD, and odors may
be present. Color changes may also indicate overloading. For example, facultative lagoons are
commonly emerald green but may change to gray, brown, black, pink, or red when
experiencing organic overloading.

As a starting point to monitor DO levels, measure DO at the effluent discharge point of each
lagoon cell. If a DO meter and boat are available, measure oxygen in the upper photic zone at
different locations throughout the lagoon system to get a better idea of the lagoon's condition.
Generally, the average DO content in the upper photic zones should be approximately 2.0 mg/L,
with 1 mg/L or below (or a pH level below 6.5) indicating conditions requiring intervention.

Note: Levels of DO vary throughout the day and night. For this reason, it is best to establish
baseline measurements for different periods throughout the day and night.

Potential Solutions

There are multiple ways to address organic overloading by either reducing organic matter in the
influent or making adjustments to the lagoon that can support increased DO concentration and
thus handle an increased organic load. For instance:

• If the lagoon receives industrial or commercial wastewater, consider asking these
facilities to improve housekeeping procedures (e.g., reduce spills, clean up raw feed
materials near floor drains, install grease traps). Alternatively, the lagoon WWTP can
consider implementing pretreatment programs.4

4 The National Pretreatment Program is a Clean Water Act regulatory program designed to control pollution
emitted from indirect dischargers, which are often commercial or industrial users that send their waste to a direct
discharger (i.e., NPDES permitholder) like a WWTP. It is always good operational practice to require industries to
institute pollution prevention practices in their facilities to minimize impacts on a lagoon system. This practice
becomes imperative if a lagoon is consistently experiencing organic overloading, pass-through, or interference. The
operator may need to require industrial users in their community to pretreat their waste before sending it to the
lagoon. Learn more about the National Pretreatment Program.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

31


-------
•	Increase aerator running time with a goal of maintaining at least 2 mg/L DO in all
treatment cells. If the DO is fluctuating, use a timer to control the aeration system to
allow operation during high-load periods, keeping DO at 2 mg/L or more at all times.

•	If increasing the aerator running time does not provide enough oxygen, add
supplemental aeration such as surface aerators, diffusors, and/or daily operation of a
motorboat. Such changes may need approval from the permitting authority and should
be designed by a professional engineer.

•	Check for clogged d iff users:

>	If clogging is minor, increase airflow output or turn off the affected section of the
diffuser and increase diffusion in the section that is not blocked, which will
compensate for the reduced airflow in the blocked section of the diffuser.

¦	Note: Increasing the amount of air going through each diffuser beyond
design specifications should be done carefully and only temporarily as it
can increase the backpressure at the blower, potentially causing
problems depending on the severity of the clogging. Additionally,
increasing airflow can increase power and electricity costs.

>	As a cleaning option for minor clogs, introduce oxygen, ozone, or other gases
through the air lines.

¦	Note: Introducing gases through the air lines should be done with care
and following safety instructions. If none of these procedures work, the
last option would be to draw the lagoon cell down to repair or replace
diffusers.

>	If clogging is major, or if the options above do not solve the clog, draw down the
lagoon to clean, repair, or replace the diffusers.

•	Remove weeds such as duckweed if they cover more than 40 percent of the lagoon.
Removing excess weeds covering the surface of the lagoon can result in increased DO
content.

•	If there is evidence of excess sewage sludge accumulation that is causing organic
overloading beyond lagoon design, de-sludge the affected cells to increase DO (see
Section 3B).

•	If the lagoon is operated in series (e.g., flow goes through each cell in successions),
consider converting to operating in parallel (e.g., more than one cell receives
wastewater at the same stage of treatment). See Figure 4 for examples of both
methods. By splitting influent flow between two cells, the effective load reduces. The
lagoon design and actual hydraulic loading may make this step impossible since a single

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

32


-------
cell might not provide sufficient treatment in many cases. Consult the permitting
authority and a professional engineer when considering changing the cell structure.

•	Add more mixing to the final cell in the lagoon system to discourage algae growth and
improve effluent TSS.

•	If the lagoon has appropriate pumping and piping equipment, recirculate effluent to the
headworks using portable pumps to provide more oxygen.

5C. Odors

Aerated lagoons can generate lagoon odors when DO levels in the lagoon are not sufficient to
meet the demand of the organic load in the wastewater. Excessive buildup of sewage sludge on
the bottom of aerated lagoons can cause noxious odors as well. Algal overgrowth, duckweed,
seasonal inversion, and excess weed growth on lagoon banks can trap grease and organics, also
causing odors.

If multiple cells exist, use a DO probe to identify the cell causing the odor. When DO is low, the
contents might be septic, causing odors. In most cases, wastewater odors result from anaerobic
or septic conditions with no DO available for microbial respiration. As a result, sulfate-reducing
bacteria utilize the sulfate for respiration and produce malodorous hydrogen sulfide, which has
low solubility in the wastewater and is characterized by a strong rotten egg odor released to
the atmosphere. Other odorous organic compounds such as mercaptans and amines may also
be present and released.

If algal overgrowth is the suspected cause of the odor, see Section 5D.

Potential Solutions

•	Reduce organic overload, if possible (see Section 5B for details).

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

33


-------
•	Remove excess weeds, such as those
shown in Image 7, Physically remove any
excess weeds by pulling or mowing. As a
last resort, consider contracting a
licensed herbicide applicator. Take
caution as herbicide application can
harm the beneficial biological activity in
the lagoon and result in a failure to meet
permit limits.

•	In colder months, lower the water level
so that ice freezes around the weed
stem, killing the weeds.

•	If a multicell lagoon is operated in series
and organic overload occurs, consider
converting to operating in parallel: split influent flow between the first two cells,
thereby reducing the loading rate on the first cell. The lagoon design and actual
hydraulic loading may make this impossible since a single cell does not provide sufficient
treatment in many cases. Consult the permitting authority and a professional engineer
when considering changing the cell structure.

•	Increase aerator running time with a goal of at least 2.0 mg/L DO in all treatment cells. If
increasing the aerator running time does not provide enough oxygen to reduce odors,
add supplemental aeration such as surface aerators, diffusors, and/or daily operation of
a motorboat.

•	If possible, recirculate effluent from the odorous cell to the head of the plant.
5D. Algal Overgrowth

Overgrowth typically occurs in the spring and summer during extended exposure to higher
temperatures and sunlight.

Because partial-mix aerated lagoons receive oxygen through mechanical or diffused aeration,
algal photosynthesis is not important to the survival of aerobic bacteria. Surface agitation
through mixing or aeration simulates wind movement, helping remove stagnant areas of water
that are prime for algae growth. Aeration also prevents algae growth within the water column
because it evens out temperature differences and prevents algae from getting direct sunlight.
However, when mixing or aeration is inadequate, algal overgrowth can occur, causing high BOD
and TSS in the final cell.

Source: EPA.

Image 7. Excess weed growth.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

34


-------
Operators can determine the presence of algal overgrowth by examining effluent
microscopically and observing elevated algae content. Effluent from some types of lagoons may
require additional treatment or "polishing" to meet discharge permit requirements.

Potential Solutions

In addition to the potential solutions listed within Section 3D, consider these additional
potential solutions, specific to facultative lagoons:

•	Increase aerator running time at night when photosynthetic activity is reduced.

•	Where DO is reduced, increase mixing and aerator running time at all times. Increased
DO may help remove or reduce BOD, meeting BOD limits and, where applicable,
ammonia nitrogen permit limits.

•	Investigate causes of reduced DO, including poor light penetration, low detention time,
high BOD loading, or toxic industrial wastes, and address as appropriate.

5E. Inadequate Nitrification for Facilities with Ammonia Permit Limits

Nitrification is a biological process involving a group of aerobic organisms referred to as
nitrifiers that oxidize ammonia to nitrite and then to nitrate. This process occurs under aerobic
conditions, sufficient alkalinity, a favorable temperature, and other conditions such as a
sufficient detention time for the nitrifiers, suspension of nitrifiers for contact with ammonia and
nitrite, and an adequate DO concentration, usually maintained at a minimum of 2 mg/L.
Alkalinity levels above 60 mg/L of calcium carbonate are required to maintain nitrification and
depend on pH and concentrations of ammonium nitrogen. Nitrifiers grow slowly and are more
sensitive to environmental factors than compounds that remove BOD. As such, maintaining
such favorable conditions are important for facilities that rely on nitrification to meet discharge
permit limits for ammonia. Otherwise, effluent ammonia concentration can exceed permit
limits.

Providing enough oxygen to meet both the BOD and ammonia removal demand is important
for nitrification. Depending on lagoon design and the ammonia effluent limit, this may involve
increasing lagoon volume and aeration capacity to support nitrification, particularly for heavily
loaded systems.

Nitrification generally occurs over a wastewater temperature range of 4-45 °C (39-113 °F) with
35-42 °C (95-108 °F) being the optimum range. Aerated lagoons in colder climates may
experience inhibited nitrification. Increasing detention time and maintaining a higher
concentration of nitrifiers can compensate for colder temperatures. Other options include
adding sedimentation to clarifiers with solids recycle and add-on processes to support
nitrification in cold weather.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

35


-------
Facilities that decide to implement modifications may require the services of a consultant and
approval from the permitting authority.

Potential Solutions

Identify what may be causing poor ammonia removal, then consider one of the following
potential solutions depending on the cause:

•	Check for increases in BOD and ammonia loading to the lagoon and consider whether
options are available to reduce the loadings to the lagoon. In some cases, running
lagoons in parallel instead of in series may be a temporary option until the loadings are
reduced, provided adequate retention time is available. Such changes may need
approval from the permitting authority.

•	If there is considerable sewage sludge accumulation, de-sludge the affected cell (see
Section 3B).

•	Increase the DO content mechanically by removing anything blocking atmospheric
reaeration and algal photosynthesis in sunlight. This process may include removing
excessive duckweed, matted algae, or sewage sludge that is blocking the surface.

•	Supplement alkalinity by adding lime, using the facility's standard operating procedures
specific to the lagoon design and dimensions.

•	If short-circuiting is suspected, consider adding baffles to better control flow and
improve hydraulic retention time.

•	If necessary, consider conducting an engineering study of feasible options for upgrading
the lagoon facility for consistent ammonia removal.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

36


-------
6. Complete-Mix Aerated Lagoon Troubleshooting Tips

Complete-mix aerated lagoons rely on mechanical aeration for three things. The first is to
introduce enough oxygen to significantly biodegrade five-day biological oxygen demand (BOD5).
The second is to oxidize ammonia where required by permit. The third is to provide additional
mixing to suspend all solids to enhance biodegradation.

Complete-mix aerated lagoons maintain DO throughout their entire depth. These lagoons are
appropriate for treatment in warm, sunny climates. They are typically shallow, between 1-6
feet in depth, to allow sunlight to penetrate throughout the water column. To boost DO
concentration and keep all solids in suspension, aerobic lagoons use mechanical aeration.

6A.Foaming

Accumulated foam and scum in aerobic lagoons can produce unwanted odors, clog equipment,
and degrade the quality of the effluent. Foam and scum have been observed in the presence of
non-degradable surfactants and with specific filamentous microorganisms in the process water.
This condition contributes to a mechanism that floats significant amounts of solids to the
surface, producing putrid brown foam and scum. Buildup of filamentous microorganisms makes
particles more hydrophobic, making it easier for those particles to then cling to air bubbles,
resulting in foam and scum at the surface.

Oil and grease in the wastewater, low food-to-microorganism ratio, and high TSS levels have
been correlated with the presence of foam and scum. To prevent harmful effects of foaming
and scum, monitor conditions as frequently as possible, remove any buildup identified, and
address the issue with the following approaches in mind.

Potential Solutions

•	Use rakes, a portable pump that can create a water jet, or motorboats to break up scum
formations. Scum usually sinks once it is broken up. If scum remains, skim and properly
dispose of materials removed. Facilities should coordinate with state regulatory
agencies regarding potential options and related regulatory requirements for handling
scum, including potential recycling opportunities.

> If the influent regularly contains excessive fats, oils, and greases, review sewer
use ordinances and implement a fats, oils, and greases program that requires
installing grease interceptors at commercial (e.g., restaurants) and industrial
facilities.

•	Add pretreatment to prevent scum buildup in the future, such as skimming, floating
booms, or sorbent pads.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

37


-------
•	If trash accumulates in the primary treatment cell, consider modifying the influent
structure to screen it out. This process may require approval from the permitting
authority; consider applicable design standards in making modifications.

•	Study wind directions and locate transfer outlets to prevent dead pockets where scum
will tend to accumulate. Retrofits may need approval from the permitting authority and
should be designed by a professional engineer.

6B.Algal Overgrowth

Overgrowth typically occurs in the spring and summer during extended exposure to higher
temperatures and sunlight.

Because complete-mix aerated lagoons receive oxygen through mechanical or diffused
aeration, algal photosynthesis is not important to the survival of aerobic bacteria. Surface
agitation through mixing or aeration simulates wind movement, helping remove stagnant areas
of water that are prime for algae growth. Aeration also prevents algae growth within the water
column because it evens out temperature differences and prevents algae from getting direct
sunlight. However, when mixing or aeration is inadequate, algal overgrowth can occur, causing
high BOD and TSS in the final cell.

Aerobic lagoons are particularly susceptible to excessive algae growth due to warmer climates
year round. These conditions can lead to high TSS and BOD concentration in the final cell, which
contribute to higher levels of turbidity.

The presence of algal overgrowth may also be determined by examining effluent
microscopically and observing elevated algae content. Effluent from some types of lagoons may
require additional treatment or "polishing" to meet discharge permit requirements.

Potential Solutions

In addition to the potential solutions listed within Section 3D, consider these additional
potential solutions, specific to complex-mix aerated lagoons:

•	Divide the lagoon basin into a series of two or three cells using curtain walls to limit algal
growth, provided retention times do not increase.

•	In some cases, increasing aeration power intensities can provide shading by improving
suspension of solids to reduce algal growth. Additional mixing by aeration will also
remove significant quantities of carbon dioxide from the system during the night hours,
ensuring carbon dioxide becomes growth-limiting to algae earlier in the day.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

38


-------
> Note: Operators should only increase aeration times if needed and within certain
limits to prevent flocculation problems and unnecessary additional power
consumption.

•	Consider installing covers to prevent light from entering the lagoon water column,
helping to limit algae growth. Commercially available floating polyester fabrics have
been used to shade aerated lagoons. They should not cover the entire lagoon surface.
Leave sufficient room if the lagoon uses mechanical surface aerators.

•	Increase aerator running time at night when photosynthetic activity is reduced.

•	Where there is reduced DO, increase mixing and aerator running time at all times.
Increased DO may help remove or reduce BOD, meeting BOD permit limits and, where
applicable, ammonia nitrogen permit limits.

•	Investigate causes of reduced DO, including poor light penetration, low detention time,
high BOD loading, or toxic industrial wastes, and address as appropriate.

6C. Inadequate Nitrification for Facilities with Ammonia Permit Limits

Nitrification is a biological process involving a group of aerobic organisms referred to as
nitrifiers that oxidize ammonia to nitrite and then to nitrate. This process occurs under aerobic
conditions, sufficient alkalinity, a favorable temperature, and other conditions such as a
sufficient detention time for the nitrifiers, suspension of nitrifiers for contact with ammonia and
nitrite, and an adequate DO concentration, usually maintained at a minimum of 2 mg/L.
Alkalinity levels above 60 mg/L of calcium carbonate are required to maintain nitrification and
depend on pH and concentrations of ammonium nitrogen. Nitrifiers grow slowly and are more
sensitive to environmental factors than compounds that remove BOD. As such, maintaining
such favorable conditions are important for facilities that rely on nitrification to meet discharge
permit limits for ammonia. Otherwise, effluent ammonia concentration can exceed permit
limits.

Many aerobic organisms remove organic material and reduce BOD in wastewater. The
competition for oxygen restricts the growth potential of slow-growing nitrifiers. However, when
the organic material and BOD is significantly reduced, this competition is also reduced, which
allows the nitrification (i.e., ammonia removal) process to occur more efficiently. Providing
enough oxygen to meet both the BOD and ammonia removal demand is important. Depending
on lagoon design and the ammonia effluent limit, providing oxygen may involve increasing
lagoon volume and aeration capacity to support nitrification.

Nitrification generally occurs over a wastewater temperature range of 4-45 °C (39-113 °F) with
35-42 °C (95-108 °F) being the optimum range. Aerated lagoons in colder climates may
experience inhibited nitrification. Increasing detention time and maintaining a higher

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

39


-------
concentration of nitrifiers can compensate for colder temperatures. Alternative options include
adding sedimentation to clarifiers with solids recycle and add-on processes to support
nitrification in cold weather.

Facilities that decide to implement modifications may require the services of a consultant and
approval from the permitting authority.

Potential Solutions

Identify what may be causing poor ammonia removal, then consider one of the following
potential solutions depending on the cause:

•	Check for increases in BOD and ammonia loading to the lagoon and consider whether
options are available to reduce such loadings. In some cases, running lagoons in parallel
instead of in series may be a temporary option until the loadings reduce, provided
adequate retention time is available. Such changes may need approval from the
permitting authority.

•	If there is considerable sewage sludge accumulation, de-sludge the affected cell (see
Section 3B).

•	Increase the DO concentration mechanically to improve aeration.

•	Supplement alkalinity by adding lime. The amount of lime added will be based on a
standard operating procedure specific to the lagoon design and dimensions.

•	If short-circuiting is suspected, consider adding baffles to better control flow and
improve hydraulic retention time.

•	If necessary, consider conducting an engineering study of feasible options for upgrading
the lagoon facility for consistent ammonia removal.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

40


-------
Appendix A. Establishing Standard Operating Parameters for Operator
Observations and Field Measurements

This section provides recommended operator visual inspections and lagoon field measurements
for establishing standard operating parameters.

In order to effectively identify and troubleshoot lagoon upset conditions, it is important to have
standard operating parameters to allow for baseline comparisons. This section provides
recommended inspection checklists that facilities can use to help establish standard operating
parameters.

Note 1: Because all lagoons are unique, the checklists below should be considered a minimum
list of operational checks. Review equipment manuals for additional parameters that require
routine inspection and the frequency of those inspections. Use those parameters and
associated inspection frequencies to establish a routine inspection and monitoring program.

Note 2: Lagoon operating conditions may vary seasonally, or even daily, as ambient
temperatures change throughout the day and throughput varies. Establish and record standard
operating parameters for varying conditions.

Note 3: Consider compiling sample results in a spreadsheet to use in assessing baseline
conditions, parameter variability, trends, and upsets.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

41


-------
Visual Inspections

Recommended frequency: On a weekly basis (at minimum, unless otherwise specified)

~	Lagoon Area Visual Checks (Inspect Daily):

~	Weed and grass control.

~	Dike vegetation

~	Evidence of dike erosion and instability.

~	Fencing (see Image 8 for an example of poorly
maintained fencing).

~	Signs of burrowing animals.

~	Condition of outbuildings.	Source: Mike Beck, Eastern Research Group, Inc.

~	Lagoon System Visual Checks:	|mage 6. A poorly maintained

~	Floating material in each lagoon cell, such as	fence,
grease, sewage sludge, trash, floating vegetation, or mats of algae.

~	Changes in ceil color,

~	Septic odors, which indicates the presence of hydrogen sulfide and absence of
oxygen.

~	Unusually high solids or turbidity and/or floating material.

~	Water level and freeboard height (i.e., the distance between the water surface
of the lagoon and the top of the dike).

~	Evidence of sewage sludge buildup at effluent points or conveyance structures.
0 Influent and/or Effluent Flows:

~	Higher-than-normal influent and effluent flows (if applicable) that could indicate
infiltration and inflow (l&l) problems.

~	Lower-than-normal flow or rising water levels that could indicate a blockage.

~	Critical Equipment Operation Checks:

~	Operating status of pump stations.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

42


-------
Lagoon Field Measurements

Recommended frequency: Annually (at minimum)

Note 1: If possible, use a boat to take measurements at various points throughout each cell for
better data quality. If a boat is unavailable, sample influent and effluent from each cell for all
parameters below.

Note 2: To ensure data quality, it is a good practice to develop profiles for sewage sludge depth,
DO, and pH by measuring each parameter at 1-foot increments from the surface of the cell to
the bottom of the lagoon.

Recommended field measurements:

•	pH, using a pH probe.

•	DO, using a portable meter.

>	Note 1: If a DO meter is not available, conduct a visual assessment. Low DO
indicators include the presence of red streaks from stressed Daphnia magna, the
common water flea, or gray to black water due to anaerobic conditions.

>	Note 2: If measuring DO with a meter, perform the test at various times of the
day, including the morning, close to sunrise, and in the afternoon, (between 2:00
and 3:00 p.m.), to capture the low and high DO concentrations for the day.

•	Temperature, using a temperature probe.

•	Sludge depth, using a core sampler or similar.

>	Note: Aerators should be turned off when taking core sewage sludge samples.

•	Alkalinity, using a test kit.

Additional Sources of Obtaining and Establishing Baseline Operating Parameters

In addition to visual observations and operator-performed analytical tests, equipment manuals
or associated documentation can also help establish baseline operation conditions.

Consider reviewing the following documents, if available:

•	Past inspection reports.

•	If the lagoon meets state design standards, as-built construction plans.

•	NPDES permit requirements.

•	Discharge monitoring reports and plant performance records.

•	Operation and maintenance records and standard operating procedures.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

43


-------
•	Noncompliance correspondence.

•	WWTP design specifications.

•	Recommendations from the facility's past assessments or reports from technical
assistance providers.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

44


-------
Appendix B. Establishing Standard Operating Parameters Using
Laboratory Analysis

In order to effectively identify and troubleshoot lagoon upset conditions, it is important to
establish standard operating parameters to allow for baseline comparisons. This section gives a
recommended sampling approach to establish standard operating parameters using laboratory
testing.

Note 1: Because all lagoons are unique, the sampling approach shown below should be
considered a minimum. Review equipment manuals for parameters that require sampling and
testing. Also review equipment manuals for sampling frequency. Use those parameters and
associated sampling frequencies to establish a routine sampling program.

Note 2: Lagoon operating conditions may vary seasonally, or even daily, due to ambient
temperature and flow rate changes throughout the day and year. Establish and record standard
operating parameters for varying conditions.

Note 3: Consider compiling sample results in a spreadsheet to use in assessing baseline
conditions, parameter variability, trends, and upsets.

Table 3, below, is an example of a lagoon WWTP sampling approach that can be used monthly
or quarterly to identify deviations from standard operating parameters. The sampling and
analysis approach presented here is based on a three-cell lagoon configuration. The approach
will be different depending on site-specific conditions.

Table 3. Recommended sample analysis parameters.

Sample Site

Ammonia

TSS

Alkalinity

PH

bod5

Soluble

bod5

CBOD5

Temperature

DO

Influent

V



V



V

V







Cell #1
effluent

V



V



V

V



V



Cell #2
effluent

V



V



V

V



V



Cell #3
effluent

V



V



V

V



V



Final effluent

V



V



V

V



V



If resources are limited, operators may focus on certain parameters that are causing
compliance problems. The goal is to consistently collect analytical results that will help make
process control decisions.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

45


-------
Ideally, a comprehensive analysis of lagoon WWTP performance would include five years of
historical data. However, with limited data, start examining trends beginning in the second year
of data collection. Consider contacting a technical assistance provider to perform a statistical
analysis to find correlations and likely causes of noncompliance. Once enough analytical data
have been collected, use these data to identify possible causes of compliance problems and
corresponding solutions.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

46


-------
Bibliography

Kansas Department of Health and Environment. (2020). Guidance for desludging domestic
wastewater lagoons by dredging the sludge from the cell.

https://www.kdhe.ks.gov/DocumentCenter/View/9383/Desludging-Lagoon-Guidance—
Dredging-PDF.

Kansas Department of Health and Environment. (2020). Guidance for desludging domestic
wastewater lagoons by drying the sludge before removal.

https://www.kdhe.ks.gov/DocumentCenter/View/9384/Desludging-Lagoon-Guidance—
Drying-PDF.

Lamfers, J. (2016). Why is my lagoon not meeting effluent limits? A review of common

problems causing compliance issues. The Kansas Lifeline. Kansas Rural Water Association.
https://krwa.net/portals/krwa/lifeline/1611/024.pdf.

Maine Department of Environmental Protection. (2003). Microbiological and chemical testing
for troubleshooting lagoons, http://www.lagoonsonline.com/trouble-shooting-wastewater-
lagoons.htm.

Minnesota Pollution Control Agency. (2013). Stabilization pond systems operations

maintenance and management, https://www.pca.state.mn.us/sites/default/files/wq-
wwtp8-22.pdf.

Montana Department of Environmental Quality. (2015). User guide—Optimization methods
and best management practices for facultative lagoons.

https://deq.mt.gov/files/Water/TFAB/Documents/SOPs/20201023Basic%20Lagoon%20Man
ual Edited.pdf.

National Small Flows Clearinghouse. (1997). Lagoon systems can provide low-cost wastewater
treatment. Pipeline Newsletter, http://www.lagoonsonline.com/pipeline-
lagoon-article-1997-volume8.pdf

Rural Community Assistance Partnership. (2019). Wastewater lagoon basics and wastewater
lagoon troubleshooting webinars. https://www.rcap.org/resource/wastewater-lagoon-
basics and https://www.rcap.org/resource/wastewater-lagoon-troubleshooting.

U.S. EPA. (2002). Wastewater technology factsheet: Facultative lagoons. EPA/832/F-02/014.
Office of Water. Washington, D.C. https://www3.epa.gov/npdes/pubs/faclagon.pdf.

U.S. EPA. (2004). Primer for municipal wastewater treatment systems. EPA 832-R04-001. Office
of Water and Office of Wastewater Management. Washington, D.C.
https://www3.epa.gov/npdes/pubs/primer.pdf.

EPA Troubleshooting Manual for Small, Facultative, Partial-Mix Aerated, and Complete-Mix
Aerated Wastewater Lagoons

47


-------
U.S. EPA. (2011). Principles of design and operations of wastewater treatment pond systems for
plant operators, engineers, and managers. EPA/600/R-11/088. Office of Research and
Development. Washington, D.C. https://www.epa.gov/sites/default/files/2014-
09/documents/lagoon-pond-treatment-2011.pdf.

U.S. EPA. (2020). Optimizing performance of facultative wastewater lagoon systems webinars,
parts 1 and 2. Office of Compliance. Presentation by Steve Harris, President, H&S
Environmental, LLC. https://www.epa.gov/compliance/optimizing-performance-facultative-
wastewater-lagoon-systems-part-1-1 and https://www.epa.gov/compliance/optimizing-
performance-aerated-wastewater-lagoon-systems-part-2.

Utah State University Cooperative Extension. (2011). How a lagoon works for livestock
wastewater treatment.

https://digitalcommons.usu.edu/cgi/viewcontent.cgi?article=1003&context=extension curt
§£¦

Water Environment Federation. (2017). What every operator should know about wastewater
ponds. WE&TMagazine. https://www.waterenvironmenttechnology-
digital.com/waterenvironmenttechnology/februarv 2017/MobilePagedReplica.action?pm=