SEPA

United States
Environmental Protection
Agency

Analytical Methods Approved for Compliance Monitoring under the
Revised Total Coliform Rule

Analysis for the following contaminants shall be conducted in accordance with the methods in the following table, or their equivalent as
determined by EPA. The methods and monitoring requirements for these contaminants are specified in 40 CFR 141.852(a)(5).

Additional methods are listed in Appendix A to Subpart C of Part 141.

The CFR is the legal reference for approved methods and takes precedent over this table. The table should accurately reflect the
analytical methods information published in 40 CFR 141.

§141.852 - Analytical Methods and Laboratory Certification

(a)	Analytical methodology

(1)	The standard sample volume required for analysis, regardless of analytical method used, is 100 mL.

(2)	Systems need only determine the presence or absence of total coliforms and E. coli; a determination of density is not required.

(3)	The time from sample collection to initiation of test medium incubation may not exceed 30 hours. Systems are encouraged but not required to hold
samples below 10°C during transit.

(4)	If water having residual chlorine (measured as free, combined, or total chlorine) is to be analyzed, sufficient sodium thiosulfate (Na2S203) must be added
to the sample bottle before sterilization to neutralize any residual chlorine in the water sample. Dechlorination procedures are addressed in Section
9060A.2 of Standard Methods for the Examination of Water and Wastewater (20th and 21st editions).

(5)	Systems must conduct total coliform and E.coli analyses in accordance with one of the analytical methods in the table at §141.852 or one of the
alternative methods listed in Appendix A to Subpart C of Part 141.

The procedures must be done in accordance with the documents listed at paragraph (c) of §141.852 or one of the alternative methods listed in Appendix A to
Subpart C of Part 141. For Standard Methods Online, the year in which each method was approved by the Standard Methods Committee is designated by the
last two digits following the hyphen in the method number. The methods listed are the only online versions of the method that maybe used. For vendor
methods, the date of the method listed in paragraph (c) of §141.852 or Appendix A to Subpart C of Part 141 is the date/version of the approved method. The
methods listed are the only versions that may be used for compliance with this rule. Laboratories should be careful to use only the approved versions of the
methods as product packaging inserts may not be the same as the approved versions of the methods.

(b)	Laboratory certification- systems must have all compliance samples required under this subpart analyzed by a laboratory certified by EPA or a primacy
state to analyze drinking water samples. The laboratory used by the system must be certified for each method (and associated contaminant(s)) used for
compliance monitoring analyses under this rule.

(c)	Incorporate by reference - The standards required in §141.852 (a) are incorporated by reference into the regulation.

Contaminant

Office of Water (MS - 4606 M)

EPA 815-B-24-008

January 2024


-------
Page 2 of 16

Total Coliforms - lactose fermentation methods:

Method

Organization

Reference Title/Source

Date

Notes

9221 B.l, B.2

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 20th Edition
Standard Methods

1998

Lactose broth, as commercially available, may be used in lieu of
lauryl tryptose broth, if the system conducts at least 25 parallel
tests between lactose broth and lauryl tryptose broth using the
water normally tested, and if the findings from this comparison
demonstrate that the false-positive rate and the false-negative
rate for total coliforms, using lactose broth, is less than 10
percent

9221 B.l, B.2

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 21st Edition
Standard Methods

2005

Lactose broth, as commercially available, may be used in lieu of
lauryl tryptose broth, if the system conducts at least 25 parallel
tests between lactose broth and lauryl tryptose broth using the
water normally tested, and if the findings from this comparison
demonstrate that the false-positive rate and the false-negative
rate for total coliforms, using lactose broth, is less than 10
percent

9221 B.l, B.2

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 22nd Edition
Standard Methods

2012

Lactose broth, as commercially available, may be used in lieu of
lauryl tryptose broth, if the system conducts at least 25 parallel
tests between lactose broth and lauryl tryptose broth using the
water normally tested, and if the findings from this comparison
demonstrate that the false-positive rate and the false-negative
rate for total coliforms, using lactose broth, is less than 10
percent

9221 B.l, B.2,
B.3, B.4

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 23rd Edition
Standard Methods

2017

Lactose broth, as commercially available, may be used in lieu of
lauryl tryptose broth, if the system conducts at least 25 parallel
tests between lactose broth and lauryl tryptose broth using the
water normally tested, and if the findings from this comparison
demonstrate that the false-positive rate and the false-negative
rate for total coliforms, using lactose broth, is less than 10
percent

9221 B.l, B.2,
B.3, B.4

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 24th Edition
Standard Methods

2023

Lactose broth, as commercially available, may be used in lieu of
lauryl tryptose broth, if the system conducts at least 25 parallel
tests between lactose broth and lauryl tryptose broth using the
water normally tested, and if the findings from this comparison
demonstrate that the false-positive rate and the false-negative
rate for total coliforms, using lactose broth, is less than 10
percent

9221 B.l, B.2-99

Standard Methods Online

Online version. Approval year is
designated by the last 2 digits.
Only online versions cited in the

1999

Lactose broth, as commercially available, may be used in lieu of
lauryl tryptose broth, if the system conducts at least 25 parallel
tests between lactose broth and lauryl tryptose broth using the


-------
Page 3 of 16

Method

Organization

Reference Title/Source

Date

Notes





regulations or in Appendix A to
Subpart C of Part 141 are
approved.

Standard Methods



water normally tested, and if the findings from this comparison
demonstrate that the false-positive rate and the false-negative
rate for total coliforms, using lactose broth, is less than 10
percent.

9221 B.l, B.2-06

Standard Methods Online

Online version. Approval year is
designated by the last 2 digits.
Only online versions cited in the
regulations or in Appendix A to
Subpart C of Part 141 are
approved.

Standard Methods

2006

Lactose broth, as commercially available, may be used in lieu of
lauryl tryptose broth, if the system conducts at least 25 parallel
tests between lactose broth and lauryl tryptose broth using the
water normally tested, and if the findings from this comparison
demonstrate that the false-positive rate and the false-negative
rate for total coliforms, using lactose broth, is less than 10
percent

9221 D.l, D.2

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 20th Edition
Standard Methods

1998

A multiple tube enumerative format, as described in Standard
Methods for the Examination of Water and Wastewater 9221,
is approved for this method for use in presence-absence
determination under this regulation.

9221 D.l, D.2

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 21st Edition
Standard Methods

2005

A multiple tube enumerative format, as described in Standard
Methods for the Examination of Water and Wastewater 9221,
is approved for this method for use in presence-absence
determination under this regulation.

9221 D.l, D.2,
D.3

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 23rd Edition
Standard Methods

2017

A multiple tube enumerative format, as described in Standard
Methods for the Examination of Water and Wastewater 9221,
is approved for this method for use in presence-absence
determination under this regulation.

9221 D.l, D.2,
D.3

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 24th Edition

2023

A multiple tube enumerative format, as described in Standard
Methods for the Examination of Water and Wastewater 9221,
is approved for this method for use in presence-absence
determination under this regulation.

9221 D.l, D.2-99

Standard Methods Online

Online version. Approval year is
designated by the last 2 digits.
Only online versions cited in the
regulations or in Appendix A to
Subpart C of Part 141 are
approved.

Standard Methods

1999

A multiple tube enumerative format, as described in Standard
Methods for the Examination of Water and Wastewater 9221,
is approved for this method for use in presence-absence
determination under this regulation.

Total coliforms - membrane filtration methods:


-------
Page 4 of 16

Method

Organization

Reference Title/Source

Date

Notes

9222 B, C

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 20th Edition
Standard Methods

1998

All filtration series must begin with membrane filtration
equipment that has been sterilized by autoclaving.

9222 B, C

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 21st Edition
Standard Methods

2005

All filtration series must begin with membrane filtration
equipment that has been sterilized by autoclaving.

9222 B, C

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 23rd Edition
Standard Methods

2017

All filtration series must begin with membrane filtration
equipment that has been sterilized by autoclaving.

9222 B, C

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 24th Edition
Standard Methods

2023

All filtration series must begin with membrane filtration
equipment that has been sterilized by autoclaving.

9222 B, C-97

Standard Methods Online

Online version. Approval year is
designated by the last 2 digits.
Only online versions cited in the
regulations or in Appendix A to
Subpart C of Part 141 are
approved.

Standard Methods

1997

All filtration series must begin with membrane filtration
equipment that has been sterilized by autoclaving.

1604

EPA

Method 1604: Total Coliforms
and Escherichia coli in Water by
Membrane Filtration Using a
Simultaneous Detection
Technique (Ml Medium),
September 2002
EPA Method 1604

2002

All filtration series must begin with membrane filtration
equipment that has been sterilized by autoclaving.

m-ColiBlue24®Test

Hach Company

Membrane Filtration Method m-
ColiBlue24® Broth, Revision 2,
August 17,1999
m-ColiBlue 24 Test

1999

All filtration series must begin with membrane filtration
equipment that has been sterilized by autoclaving.

9222 J
m-ColiBlue24®Test

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 23rd Edition
Standard Methods

2017

All filtration series must begin with membrane filtration
equipment that has been sterilized by autoclaving.


-------
Page 5 of 16

Method

Organization

Reference Title/Source

Date

Notes

9222 J
m-ColiBlue24®Test

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 24th Edition
Standard Methods

2023



Chromocult

EMD Millipore

Chromocult® Coliform Agar
Presence/Absence Membrane
Filter Test Method for Detection
and Identification of Coliform
Bacteria and Escherichia coli for
Finished Waters, November
2000, Version 1.0
Chromocult

2000

All filtration series must begin with membrane filtration
equipment that has been sterilized by autoclaving.

RAPID'E.coli 2
(REC 2)

Bio-Rad

Simultaneous Detection of Total
Coliform Bacteria and Escherichia
coli using RAPID'E.coli 2 (REC 2) in
Drinking Water, May 2020.
RAPID'E.coli 2

2020

All filtration series must begin with membrane filtration
equipment that has been sterilized by autoclaving.

Total coliforms - enzyme substrate methods:

Method

Organization

Reference Title/Source

Date

Notes

9223 B
Colilert®

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 20th Edition
Standard Methods

1998

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence
determination under this regulation.

9223 B
Colilert®

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 21st Edition
Standard Methods

2005

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence
determination under this regulation.

9223 B
Colilert®

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 22nd Edition
Standard Methods

2012

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence
determination under this regulation.

9223 B
Colilert®

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 23rd Edition
Standard Methods

2017

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence
determination under this regulation.

9223 B
Colilert®

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 24th Edition

2023

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence
determination under this regulation.


-------
Page 6 of 16

Method

Organization

Reference Title/Source

Date

Notes





Standard Methods





9223 B-97
Colilert®

Standard Methods Online

Online version. Approval year is
designated by the last 2 digits.
Only online versions cited in the
regulations or in Appendix A to
Subpart C of Part 141 are
approved.

Standard Methods

1997

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence
determination under this regulation.

9223 B-04
Colilert®

Standard Methods Online

Online version. Approval year is
designated by the last 2 digits.
Only online versions cited in the
regulations or in Appendix A to
Subpart C of Part 141 are
approved.

Standard Methods

2004

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence
determination under this regulation.

9223 B
Colisure®

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 20th Edition
Standard Methods

1998

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence
determination under this regulation.

Colisure results may be read after an incubation time of 24
hours.

9223 B
Colisure®

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 21st Edition
Standard Methods

2005

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence
determination under this regulation.

Colisure results may be read after an incubation time of 24
hours.

9223 B
Colisure®

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 22nd Edition
Standard Methods

2012

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence
determination under this regulation.

Colisure results may be read after an incubation time of 24
hours.

9223 B
Colisure®

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 23rd Edition
Standard Methods

2017

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence
determination under this regulation.

Colisure results may be read after an incubation time of 24
hours.


-------
Page 7 of 16

Method

Organization

Reference Title/Source

Date

Notes

9223 B
Colisure®

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 23rd Edition
Standard Methods

2023

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence
determination under this regulation.

Colisure results may be read after an incubation time of 24
hours.

9223 B-97
Colisure®

Standard Methods Online

Online version. Approval year is
designated by the last 2 digits.
Only online versions cited in the
regulations or in Appendix A to
Subpart C of Part 141 are
approved.

Standard Methods

1997

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence
determination under this regulation.

Colisure results may be read after an incubation time of 24
hours.

9223 B-04
Colisure®

Standard Methods Online

Online version. Approval year is
designated by the last 2 digits.
Only online versions cited in the
regulations or in Appendix A to
Subpart C of Part 141 are
approved.

Standard Methods

2004

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence
determination under this regulation.

Colisure results may be read after an incubation time of 24
hours.

9223 B
Colilert-18®

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 20th Edition
Standard Methods

1998

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence
determination under this regulation.

9223 B
Colilert-18®

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 21st Edition
Standard Methods

2005

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence
determination under this regulation.

9223 B
Colilert-18®

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 22nd Edition
Standard Methods

2012

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence
determination under this regulation.

9223 B
Colilert-18®

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 23rd Edition
Standard Methods

2017

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence
determination under this regulation.

9223 B
Colilert-18®

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 24th Edition
Standard Methods

2023

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence
determination under this regulation.


-------
Page 8 of 16

Method

Organization

Reference Title/Source

Date

Notes

9223 B-04
Colilert-18®

Standard Methods Online

Online version. Approval year is
designated by the last 2 digits.
Only online versions cited in the
regulations or in Appendix A to
Subpart C of Part 141 are
approved.

Standard Methods

2004

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence
determination under this regulation.

E*Colite®

Charm Sciences

Charm E*Colite™
Presence/Absence Test for
Detection and Identification of
Coliform Bacteria and Escherichia
coli in Drinking Water,
January 9,1998
Charm E*Colite

1998



Readycult®

EMD Millipore

Readycult® Coliforms 100
Presence/Absence Test for
Detection and Identification of
Coliform Bacteria and Escherichia
coli in Finished Waters,
January 2007,

Version 1.1
Readvcult

2007



Modified
Colitag™

CPI International, Inc.

Modified Colitag™ Test Method
for the Simultaneous Detection
of E. coli and other Total
Coliforms in water (ATP D05-
0035), August 28, 2009
Modified Colitag

2009



Modified
Colitag™, version
2.0

Neogen Corp.

Modified Colitag™ Test Method
for the Simultaneous Detection
of Total Coliforms and E. coli in
Water, June 2020
Modified Colitag, version 2.0

2020



Tecta EC/TC, v.
1.0

Veolia Water Solutions and
Technologies

Tecta™ EC/TC medium and the

Tecta™ Instrument: A
Presence/Absence Method for
the Simultaneous Detection of
Total Coliforms and Escherichia
coli (E. coli) in Drinking Water,
May 2014, Version 1.0

2014




-------
Page 9 of 16

Method

Organization

Reference Title/Source

Date

Notes





Tecta, Version 1.0





Tecta EC/TC, v.
2.0

Pathogen Detection Systems, Inc.

Tecta™ EC/TC medium and the

Tecta™ Instrument: A
Presence/Absence Method for
the Simultaneous Detection of
Total Coliforms and Escherichia
coli (E. coli) in Drinking Water,
March 2017, Version 2.0
Tecta, Version 2.0

2017



Contaminant

Escherichia coli ¦

Procedure (following Lactose Fermentation Methods):

Method

Organization

Reference Title/Source

Date

Notes

9221 F.l

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 20th Edition
Standard Methods

1998



9221 F.l

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 21st Edition
Standard Methods

2005



9221 F.l

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 22nd Edition
Standard Methods

2012



9221 F.l

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 23rd Edition
Standard Methods

2017



9221 F.l

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 24th Edition
Standard Methods

2023




-------
Page 10 of 16

Method

Organization

Reference Title/Source

Date

Notes

9221 F.l-06

Standard Methods Online

Online version. Approval year is
designated by the last 2 digits.
Only online versions cited in the
regulations or in Appendix A to
Subpart C of Part 141 are
approved.

Standard Methods

2006



Contaminant

Escherichia coli ¦

Partition methods:

Method

Organization

Reference Title/Source

Date

Notes

9222 G.lc(2)

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 20th Edition
Standard Methods

1998



9222 G.lc(2)

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 21st Edition
Standard Methods

2005



9222 H

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 23rd Edition
Standard Methods

2017



9222H

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 24th Edition
Standard Methods

2023



9222 G.lc(l)

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 20th Edition
Standard Methods

1998



9222 G.lc(l)

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 21st Edition
Standard Methods

2005




-------
Page 11 of 16

Method

Organization

Reference Title/Source

Date

Notes

9222 1

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 23rd Edition
Standard Methods

2017



9222 1

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 24th Edition
Standard Methods

2023



Contaminant

Escherichia coli - membrane filtration methods:

Method

Organization

Reference Title/Source

Date

Notes

1604

EPA

Method 1604: Total Coliforms
and Escherichia coli in Water by
Membrane Filtration Using a
Simultaneous Detection
Technique (Ml Medium),
September 2002
EPA Method 1604

2002

All filtration series must begin with membrane filtration
equipment that has been sterilized by autoclaving.

m-

ColiBlue24®Test

Hach Company

Membrane Filtration Method m-
ColiBlue24® Broth, Revision 2,
August 17,1999
m-ColiBlue 24 Test

1999

All filtration series must begin with membrane filtration
equipment that has been sterilized by autoclaving.

9222 J

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 23rd Edition
Standard Methods

2017

All filtration series must begin with membrane filtration
equipment that has been sterilized by autoclaving.

9222 J

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 24th Edition
Standard Methods

2023

All filtration series must begin with membrane filtration
equipment that has been sterilized by autoclaving.

Chromocult

EMD Millipore

Chromocult® Coliform Agar
Presence/Absence Membrane
Filter Test Method for Detection
and Identification of Coliform
Bacteria and Escherichia coli for
Finished Waters, November
2000, Version 1.0
Chromocult

2000

All filtration series must begin with membrane filtration
equipment that has been sterilized by autoclaving.


-------
Page 12 of 16

Method

Organization

Reference Title/Source

Date

Notes

RAPID'E.coli 2
(REC 2)

Bio-Rad

Simultaneous Detection of Total
Coliform Bacteria and
Escherichia coli using
RAPID'E.coli 2 (REC 2) in
Drinking Water, May 2020.
RAPID'E.coli 2

2020

All filtration series must begin with membrane filtration
equipment that has been sterilized by autoclaving.

Contaminant

Escherichia coli - enzyme substrate methods:

Method

Organization

Reference Title/Source

Date

Notes

9223 B
Colilert®

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 20th Edition
Standard Methods

1998

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence determination
under this regulation.

9223 B
Colilert®

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 21st Edition
Standard Methods

2005

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence determination
under this regulation.

9223 B
Colilert®

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 22nd Edition
Standard Methods

2012

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence determination
under this regulation.

9223 B
Colilert®

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 23rd Edition
Standard Methods

2017

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence determination
under this regulation.

9223 B
Colilert®

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 24th Edition
Standard Methods

2023

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence determination
under this regulation.

9223 B
Colilert® B-97

Standard Methods Online

Online version. Approval year is
designated by the last 2 digits.
Only online versions cited in the
regulations or in Appendix A to
Subpart C of Part 141 are
approved.

Standard Methods

1997

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence determination
under this regulation.


-------
Page 13 of 16

Method

Organization

Reference Title/Source

Date

Notes

9223 B
Colilert® B-04

Standard Methods Online

Online version. Approval year is
designated by the last 2 digits.
Only online versions cited in the
regulations or in Appendix A to
Subpart C of Part 141 are
approved.

Standard Methods

2004

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence determination
under this regulation.

9223 B
Colisure®

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 20th Edition
Standard Methods

1998

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence determination
under this regulation.

Colisure results may be read after an incubation time of 24 hours.

9223 B
Colisure®

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 21st Edition
Standard Methods

2005

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence determination
under this regulation.

Colisure results may be read after an incubation time of 24 hours.

9223 B
Colisure®

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 22nd Edition
Standard Methods

2012

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence determination
under this regulation.

Colisure results may be read after an incubation time of 24 hours.

9223 B
Colisure®

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 23rd Edition
Standard Methods

2017

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence determination
under this regulation.

Colisure results may be read after an incubation time of 24 hours.

9223 B
Colisure®

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 24th Edition
Standard Methods

2023

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence determination
under this regulation.

Colisure results may be read after an incubation time of 24 hours.

9223 B-97
Colisure®

Standard Methods Online

Online version. Approval year is
designated by the last 2 digits.
Only online versions cited in the
regulations or in Appendix A to
Subpart C of Part 141 are
approved.

Standard Methods

1997

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence determination
under this regulation.

Colisure results may be read after an incubation time of 24 hours.


-------
Page 14 of 16

Method

Organization

Reference Title/Source

Date

Notes

9223 B
Colisure® B-04

Standard Methods Online

Online version. Approval year is
designated by the last 2 digits.
Only online versions cited in the
regulations or in Appendix A to
Subpart C of Part 141 are
approved.

Standard Methods

2004

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence determination
under this regulation.

Colisure results may be read after an incubation time of 24 hours.

9223 B
Colilert-18®

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 20th Edition
Standard Methods

1998

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence determination
under this regulation.

9223 B
Colilert-18®

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 21st Edition
Standard Methods

2005

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence determination
under this regulation.

9223 B
Colilert-18®

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 22nd Edition
Standard Methods

2012

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence determination
under this regulation.

9223 B
Colilert-18®

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 23rd Edition
Standard Methods

2017

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence determination
under this regulation.

9223 B
Colilert-18®

Standard Methods

Standard Methods for the
Examination of Water and
Wastewater, 24th Edition
Standard Methods

2023

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence determination
under this regulation.

9223 B-04
Colilert-18®

Standard Methods Online

Online version. Approval year is
designated by the last 2 digits.
Only online versions cited in the
regulations or in Appendix A to
Subpart C of Part 141 are
approved.

Standard Methods

2004

Multiple-tube and multi-well enumerative formats for this
method are approved for use in presence-absence determination
under this regulation.


-------
Page 15 of 16

Method

Organization

Reference Title/Source

Date

Notes

E*Colite®

Charm Sciences

Charm E*Colite™
Presence/Absence Test for
Detection and Identification of
Coliform Bacteria and
Escherichia coli in Drinking
Water,

January 9,1998
Charm E*Colite

1998



Readycult®

EMD Millipore

Readycult® Coliforms 100
Presence/Absence Test for
Detection and Identification of
Coliform Bacteria and
Escherichia coli in Finished
Waters,

January 2007,

Version 1.1
Readvcult

2007



Modified
Colitag™

CPI International, Inc.

Modified Colitag™ Test Method
for the Simultaneous Detection
of E. coli and other Total
Coliforms in water (ATP D05-
0035), August 28, 2009
Modified Colitag

2009



Modified
Colitag™,
version 2.0

Neogen Corp.

Modified Colitag™ Test Method
for the Simultaneous Detection
of Total Coliforms and E. coli in
Water, June 2020
Modified Colitag, version 2.0

2020



Tecta EC/TC, v.
1.0

Veolia Water Solutions and
Technologies

Tecta™ EC/TC medium and the

Tecta™ Instrument: A
Presence/Absence Method for
the Simultaneous Detection of
Total Coliforms and Escherichia
coli (E. coli) in Drinking Water,
May 2014, Version 1.0
Tecta, Version 1.0

2014




-------
Page 16 of 16

Method

Organization

Reference Title/Source

Date

Notes

Tecta EC/TC, v.
2.0

Pathogen Detection Systems, Inc.

Tecta™ EC/TC medium and the

Tecta™ Instrument: A
Presence/Absence Method for
the Simultaneous Detection of
Total Coliforms and Escherichia
coli (E. coli) in Drinking Water,
March 2017, Version 2.0
Tecta, Version 2.0