Overview of Carbon Monoxide (CO) Air Quality in the United States

Updated: June 09, 2022

1.	Introduction

The overall purpose of this document is to maintain an up-to-date graphical summary of air quality information that
supports the review of the National Ambient Air Quality Standards (NAAQS) for carbon monoxide (CO). In previous
reviews of the CO NAAQS, this type of information has generally been included in atmospheric sections of the Integrated
Science Assessment (ISA) and Policy Assessment (PA) for carbon monoxide. This stand-alone document will either replace
or complement the air quality emissions and monitoring data in the atmospheric sections of future CO NAAQS documents,
and will be updated at regular intervals as new data becomes available.

The content of past NAAQS documents' atmospheric sections has included major sections on emissions and concentration
trends utilizing maps and data from the EPA's National Emissions Inventory (NEI) and the EPA's Air Quality System
(AQS) database. In past NAAQS reviews, this often involved adaptation of figures and tables prepared for other reports, or
development of new figures and tables using data analysis and mapping software. Additionally, the release of updated emission
inventories and ambient monitoring data may not coincide with the schedule for the development of NAAQS documents. As a
result, data access and resources can limit the availability of the most recent information for inclusion in NAAQS documents.

This stand-alone document allows the content to be updated as soon as new data becomes available, rather than pulling
from whatever is available at the time of publication. It also ensures that the public will have access to a consistent set of
maps and figures for each NAAQS pollutant that are updated on a routine basis, rather than separated by several years
following the disparate schedules of the various NAAQS reviews for each pollutant. Moreover, a stand-alone document can be
expanded to include new air quality analyses as they are completed, rather than following the timeline for the public release
of the NAAQS documents. Finally, this document takes advantage of a more flexible digital format for the routinely prepared
maps and trends figures, with an end product that more strongly emphasizes visual presentation of data and reduces the
amount text, while also creating a more interactive presentation of the information through the use of external links.

This document follows an organization similar to the structure of the atmospheric sections of past CO NAAQS documents.
The subsequent sections are as follows: 2. Atmospheric Chemistry; 3. Sources and Emissions of CO; 4. Ambient Air
Monitoring Requirements and Monitoring Networks; 5. Data Handling Conventions and Computations for Determining
Whether the Standards are Met; and 6. CO Concentrations Measured at Ambient Air Monitoring Sites Across the U.S.
These sections are broad enough in scope to handle changes in what is known about CO atmospheric science as it advances
but specific enough that NAAQS-relevant information will be able to be quickly retrieved by users of the document.

2.	Atmospheric Chemistry

CO is formed primarily by incomplete combustion of carbon-containing fuels and photochemical reactions in the atmo-
sphere. In general, any increase in fuel O2 content, burn temperature, or mixing time in the combustion zone will tend to
decrease production of CO relative to CO2. CO emissions from large fossil-fueled power plants are typically very low since
the boilers at these plants are tuned for highly efficient combustion with the lowest possible fuel consumption. In contrast,
internal combustion engines used in many mobile sources have widely varying operating conditions. Therefore, higher and
more varying CO formation results from the operation of these mobile sources.

Oxidation of anthropogenic and biogenic volatile organic compounds (VOCs) constitute important secondary sources
of CO. Secondary CO production occurs by photooxidation of methane (CH4) and other VOCs, including nonmethane
hydrocarbons (NMHCs) in the atmosphere and organic molecules in surface waters and soils. Photolysis of formaldehyde
(CH2O) proceeds by two pathways. The first produces molecular hydrogen (H2) and CO with a reaction yield of 55% in
conditions of clear skies and low zenith angles; the second yields a hydrogen radical (H) and the formyl radical (HCO). HCO
then reacts with O2 to form hydroperoxy radical (HO2; OH and HO2 together are termed HOx) and CO. Reaction of methyl
peroxy radical (CH3O2) with HO2 radicals to form methyl hydroperoxide (CH3OOH) is also operative, especially in low
oxides of nitrogen (NOx) conditions. Heterogeneous removal of the partially water-soluble intermediate products, such as
CH3OOH and CH2O, will decrease CO yields from CH4 oxidation.

1


-------
While oxidation of CH2O nearly always produces GO and some small quantities of formic acid (CH2O2) in the reaction of
CH2O with HO2, oxidation of acetaldehyde (CH3CHO) does not always yield two GO molecules. Reaction of CH3CHO with
OH can yield acetyl radicals (CH3CO) which then will participate with O2 in a termolecular recombination reaction to form
peroxyacyl radicals, which then can react with nitric oxide (NO) to form CH3 and CO2. The peroxyacyl radicals may also
react with NO2 to form peroxyacetyl nitrate (PAN), CH3CO3NO2. In this way, one carbon atom is oxidized directly to CO2
without passing through GO. The yield of GO from these pathways depends on the OH concentration and the photolysis rate
of CH3CHO, as well as on the abundance of NO, since peroxyacyl radicals also will react with other odd hydrogen radicals
like IK); .

Estimating the GO yield from oxidation of hydrocarbons (HGs) larger than CH4 requires computing the yields of CH2O,
CH3CHO, CH3CO, and analogous radicals from oxidation of the parent molecules. Moreover, the extent of heterogeneous
removal of soluble intermediate products also affects oxidation of more complex HGs. However, the detailed gas-phase kinetics
for many HGs with more than a few carbons is still unknown. This is especially the case for several important classes of VOGs,
including the aromatics, biogenic HGs including isoprene, and their intermediate oxidation products like epoxides, nitrates,
and carbonyls. Mass-balance analyses performed on irradiated smog chamber mixtures of aromatic HGs indicate that only
about one-half of the carbon is in the form of compounds that can be identified. In addition, reactions like the oxidation of
terpenes that produce condensable products are also significant because these reactions produce secondary organic aerosols,
thereby reducing the potential yield of GO.

The major pathway for removal of GO from the atmosphere is reaction with OH to produce CO2 and H radicals that rapidly
combine with O2 to form HO2 radicals. The mean tropospheric photochemical lifetime of GO in the northern hemisphere is
estimated to be about 57 days. Owing to variation in atmospheric water vapor, OH concentration, and insolation, shorter
photochemical lifetimes are found nearer the tropics and longer ones at higher latitudes. During winter at high latitudes, GO
has nearly no photochemical reactivity on urban and regional scales. Because the GO lifetime is shorter than the roughly
one year characteristic time scale for mixing between the hemispheres and because northern hemisphere GO emissions are
higher due to anthropogenic activity, a large gradient in concentrations exists between the hemispheres. In addition, the
GO lifetime at high latitudes is long enough to result in much smaller gradients between 30° latitude and the pole of either
hemisphere. The typical residence time of GO in urban areas when assuming a diel-average OH concentration of 3xl06/cm3
in urban areas is about 16 days, so GO will not typically be destroyed in urban areas where it is emitted and will likely be
mixed on continental and larger scales. OH concentrations are orders of magnitude lower in indoor environments, and so GO
will generally not be affected by indoor air reactions.

Sources: Integrated Science Assessment for Carbon Monoxide, January 2010 (Chapter 3)

Policy Assessment for the Review of the Carbon Monoxide NAAQS, October 2010 (Chapter 1)

3. Sources and Emissions of CO

Mobile sources are the largest anthropogenic source of CO emissions in the U.S., comprising 44% of total GO emissions in
2017 (Figure 1). CO emissions from internal combustion engines vary substantially with ambient temperature and operating
conditions. Substantial light-duty gasoline vehicle GO emissions occur during the cold start before the catalyst is warmed
up. Lower ambient temperatures result in increased CO emissions because ignition engines are required to run richer air:fuel
ratios for longer periods of time. Increased vehicle GO emissions can also occur under conditions such as high rates of
acceleration, rapid speed fluctuations, heavy-vehicle load demands (such as occur while pulling a trailer or going up a steep
hill), and use of air-conditioning. Moreover, the gasoline-powered spark ignition engines that predominate in light-duty
on-road vehicles have higher uncontrolled CO emission rates than other combustion sources because they typically operate
closer to the stoichiometric air-to-fuel ratio, have relatively short residence times at peak combustion temperatures, and
have very rapid cooling of cylinder exhaust gases. By contrast, the diesel-powered engines that predominate in heavy-duty
onroad vehicles and in off-road and non-road fixed combustion sources have much lower engine-out GO emissions than do
the spark-ignition engines because the diesels typically operate at very high air-to-fuel ratios, which promote mixing oxygen
and fuel, thus improving carbon burn.

Another important source of CO emissions is fires, which consists of wildfires, agricultural field burning to control
the growth of unwanted plants on crop and pasture land, and prescribed burns to manage forest resources. Although it is
generally accepted that a large proportion of wildfires are anthropogenic in origin, wildfires are typically treated as natural
emissions in emissions inventories, while agricultural and prescribed fires are treated as anthropogenic. Fires made up 40%
of total U.S. GO emissions in 2017, though wildfires especially tend to exhibit large interannual variability mostly due to
fluctuations in meteorological conditions. Other important sources of CO emissions include stationary fuel combustion, which
includes emissions from coal-, gas-, and oil-fired power plants and industrial, commercial, and institutional sources, as well as
residential heaters (e.g., wood-burning stoves) and boilers; industrial processes, which include chemical production, petroleum
refining and metals production, and natural emissions from plants and soil (biogenics).

2


-------
The National Emissions Inventory (NEI) is a comprehensive and detailed estimate of air emissions of criteria pollutants,
precursors to criteria pollutants, and hazardous air pollutants from air emissions sources. The NEI is released every three
years based primarily upon data provided by State, Local, and Tribal air agencies for sources in their jurisdictions and
supplemented by data developed by the US EPA. The NEI is built using the EPA's Emissions Inventory System (EIS) first
to collect the data from State, Local, and Tribal air agencies and then to blend that data with other data sources.

Accuracy in an emissions inventory reflects the extent to which the inventory represents the actual emissions that occurred.
Anthropogenic emissions of air pollutants result from a variety of sources such as power plants, industrial sources, motor
vehicles and agriculture. The emissions from any individual source typically varies in both time and space. For the thousands
of sources that make up the NEI, there is uncertainty in one or both of these factors. For some sources, such as power plants,
direct emission measurements enable the emission factors derived from them to be more certain than sources without such
direct measurements. However, it is not practically possible to directly monitor each of the emission sources individually and,
therefore, emission inventories necessarily contain assumptions, interpolation and extrapolation from a limited set of sample
data.

CO Emissions (70,794 kTon/year)

Figure 1. U.S. GO emissions (tons/year) by sector. Source: 2017 NEI.

Figure 2 shows the national trend in U.S. anthropogenic GO emissions by sector from 2002 to 2021. Nationally, GO
emissions have decreased by 51% since 2002, mostly due to reductions in mobile source emissions. Figure 3 shows the GO
emissions density in tons/mi2/year for each U.S. county based on the 2017 NEI. The majority of GO emissions tend to be
located near urban areas, which tend to have the most vehicle traffic and industrial sources. However, there are also some
counties in rural areas with higher GO emissions due to fires or the presence of large stationary sources such as power plants.

3


-------
~T~

O
CM

CM
o
o
CM

LO

o
o
CM

00

o
o
CM

o
CM

o
CM

o
CM
o
CM

Inventory Year

Figure 2. U.S. anthropogenic NOx emissions trend, 2002-2021. Source: EPA's Air Pollutant Emissions Trends Data

Carbon Monoxide Emissions Density in tons/year/miA2 (# Counties)
~ 10-19.9 (945) ~ 20-49.9(840) ~ 50-99.9(279)

Figure 3. U.S. county-level CO emissions density estimates in tons/year/mi2. Source: 2017 NEI


-------
4. Ambient Air Monitoring Requirements and Monitoring Networks

Ambient GO concentrations are measured by monitoring networks that are operated by state and local monitoring
agencies in the U.S., which are typically funded in part by the EPA. There were 289 monitoring sites reporting hourly GO
concentration data to the EPA during the 2019-2021 period. The locations of these monitoring sites are shown in Figure
4. The main network providing ambient data for use in comparison to the NAAQS is the State and Local Air Monitoring
Stations (SLAMS) network, which consists of nearly 90% of all GO monitoring sites in the U.S. Currently there are no
minimum monitoring requirements for the number of GO monitoring sites, except as part of the NCore and near-road
networks as discussed below. However, continued operation of existing SLAMS sites is required unless discontinuation is
approved by the EPA Regional Administrator. Further, in areas where SLAMS GO monitoring is ongoing, at least one site
must be a maximum concentration site for the area.

Two important subsets of SLAMS sites are the National Gore (NCore) multi-pollutant monitoring network and the
near-road network. The NCore network, designed to collect consistent measurements of criteria pollutants for trends and
NAAQS compliance purposes, was fully implemented in 2011 and consists of approximately 60 urban monitoring stations
and 20 rural monitoring stations. Each state is required to have at least one NCore station. The near-road monitoring
network, which began operating in 2014, requires sites to operate near major roadways in each metropolitan statistical area
(MSA) with a population of 1,000,000 or greater. There were 59 near-road monitors collecting CO measurements during the
2019-2021 period.

Finally, there are also a number of Special Purpose Monitors (SPMs), which are not required but are often operated by
air agencies for short periods of time (i.e., less than 3 years) to collect data for human health and welfare studies, as well as
other types of monitoring sites, including monitors operated by tribes and industrial sources. The SPMs are typically not
used to assess compliance with the NAAQS.

• SLAMS (124) • NCORE (77) O NEAR ROAD (59) • SPM/OTHER (29)

Figure 4: Map of U.S. CO monitoring sites reporting data to the EPA during the 2019-2021 period. Source: AQS.

EPA has established federal reference methods (FRMs) and methods designated as equivalent (federal equivalent methods,
FEMs) for use in ambient air sample collection and analysis to promote uniform enforcement of the air quality standards
set forth under the CAA. Measurements for determinations of NAAQS compliance must be made with FRMs or FEMs.

5


-------
Prior to 2006, GO monitoring instruments typically had a lower detection limit (LDL) of 0.5 ppm. This is sufficient for the
purpose of determining compliance with the GO NAAQS, but with many areas routinely measuring GO levels below 1 ppm,
a large percentage of the measurements from these monitors were below the LDL of these instruments, which contributed to
greater measurement uncertainties. Since 2005, the older instruments have slowly been replaced with a new generation of
'trace-level' instruments, which have LDLs on the order of 0.02 to 0.04 ppm. As of 2021, about half of the GO monitoring
network consists of measurements from these newer trace-level instruments.

5. Data Handling Conventions and Computations for Determining Whether the Standards
are Met

To assess whether a monitoring site or geographic area (usually a county or urban area) meets or exceeds a NAAQS, the
monitoring data are analyzed consistent with the established regulatory requirements for the handling of monitoring data
for the purposes of deriving a design value. A design value summarizes ambient air concentrations for an area in terms of
the indicator, averaging time and form for a given standard such that its comparison to the level of the standard indicates
whether the area meets or exceeds the standard. There are currently two GO NAAQS in effect: the 1-hour NAAQS of 35
ppm and the 8-hour NAAQS of 9 ppm, neither to be exceeded more than once per year.1

Hourly GO measurement data collected at an ambient air monitoring site using Federal Reference or Equivalent Methods,
meeting all applicable requirements in 40 GFR Part 58, and reported to AQS in parts per million (ppm) with decimal digits
after the first decimal place truncated are used in design value calculations. The design value for the 1-hour and 8-hour GO
NAAQS are evaluated for each monitor based on hourly concentration data collected over two consecutive calendar years.
For the 1-hour GO NAAQS, the 2nd highest hourly concentration in each year is determined, and the design value is the
higher of these two annual 2nd maximum values, rounded to the nearest ppm. The 1-hour NAAQS is met when the design
value is less than or equal to 35 ppm.

For the 8-hour NAAQS, rolling 8-hour averages are computed from the hourly concentration data for each 8-hour period
over the 2 years. The 8-hour averages are stored in the last hour of each 8-hour period (e.g., for the 8-hour period from
8:00 AM to 3:59 PM, the 8-hour average is stored in the 3:00 PM hour). Each 8-hour average is considered valid if hourly
concentrations are available for at least 6 of the 8 hours in the 8-hour period. For each of the 2 years, the 2nd highest
non-overlapping 8-hour average concentration is determined, and the design value is the higher of these two annual 2nd
maximum values, rounded to the nearest ppm. The 8-hour NAAQS is met when the design value is less than or equal to 9
ppm. Unlike the other pollutants, there are no minimum data completeness requirements for determining valid 1-hour and
8-hour GO design values.

The procedures for calculating design values for the GO NAAQS are documented in 40 GFR §50.8 and (Laxt.on, 1990).

6


-------
6. CO Concentrations Measured at Ambient Air Monitoring Sites Across the U.S.

Table 1 below presents summary statistics based on three daily GO metrics, the daily maximum 1-hour (MDA1) metric,
the daily maximum 8-hour (MDA8) metric, and the daily 24-hour average (DA24) metric. These statistics are presented for
year-round and each season (winter=Dec/Jan/Feb, spring=Mar/Apr/May, summer=Jun/Jul/Aug, autumn=Sep/Oct/Nov)
for monitors that have complete data (defined as having at least 75% data completeness) in AQS for 2019-2021.

Table 1. National distribution of GO concentrations in ppm for 2019-2021. Source: AQS.

metric

season

N.sites

N.obs

mean

SD

min

Pi

p5

plO

p25

p50

p75

p90

p95

p98

p99

max

max.site

MDA1

all

233

245,210

0.5

0.4

-0.4

0.0

0.1

0.2

0.2

0.4

0.6

1.0

1.2

1.5

1.8

35.0

060531003

MDA1

winter

233

60,899

0.6

0.5

-0.3

0.1

0.1

0.2

0.3

0.5

0.8

1.2

1.4

1.8

2.1

35.0

060531003

MDA1

spring

230

61,676

0.4

0.3

-0.3

0.0

0.1

0.2

0.2

0.3

0.5

0.8

0.9

1.2

1.3

9.4

420031376

MDA1

summer

226

60,361

0.4

0.3

-0.4

0.0

0.1

0.1

0.2

0.3

0.5

0.7

0.9

1.1

1.3

6.1

410670005

MDA1

autumn

222

58,468

0.6

0.5

-0.4

0.0

0.1

0.2

0.3

0.5

0.8

1.1

1.3

1.7

2.0

21.4

517100024

MDA8

all

233

245,155

0.4

0.3

-0.4

0.0

0.1

0.1

0.2

0.3

0.5

0.7

0.9

1.1

1.3

14.3

410670005

MDA8

winter

233

60,888

0.5

0.3

-0.4

0.0

0.1

0.2

0.2

0.4

0.6

0.9

1.1

1.3

1.5

5.3

060531003

MDA8

spring

230

61,669

0.3

0.2

-0.3

0.0

0.1

0.1

0.2

0.3

0.4

0.6

0.7

0.8

0.9

4.3

420031376

MDA8

summer

226

60,362

0.3

0.2

-0.4

0.0

0.1

0.1

0.2

0.3

0.4

0.6

0.7

0.8

1.0

3.4

410670005

MDA8

autumn

221

58,228

0.4

0.3

-0.4

0.0

0.1

0.2

0.2

0.4

0.6

0.8

1.0

1.3

1.5

14.3

390350051

DA24

all

233

245,210

0.3

0.2

-0.4

0.0

0.1

0.1

0.2

0.2

0.4

0.5

0.6

0.8

0.9

10.5

410670005

DA24

winter

233

60,899

0.3

0.2

-0.4

0.0

0.1

0.1

0.2

0.3

0.4

0.6

0.7

0.9

1.0

2.5

020200018

DA24

spring

230

61,676

0.2

0.1

-0.3

0.0

0.1

0.1

0.2

0.2

0.3

0.4

0.5

0.6

0.7

1.8

420031376

DA24

summer

226

60,361

0.2

0.2

-0.4

0.0

0.0

0.1

0.1

0.2

0.3

0.4

0.5

0.6

0.7

1.6

020200018

DA24

autumn

222

58,468

0.3

0.2

-0.4

0.0

0.1

0.1

0.2

0.3

0.4

0.6

0.7

0.8

1.0

10.5

390350060

N.sites = number of sites; N.obs = number of observations; SD = standard deviation; min = minimum; pi, p5, plO, p25,
p50, p90, p95, p98, p99 = 1st, 5th, 10th, 25th, 50th, 90th, 95th, 98th, 99th percentiles; max = maximum; max.site = AQS ID
number for the monitoring site corresponding to the observation in the max column, winter = December/January/February;
spring = March/April/May; summer = June/July/August; autumn = September/October/November.

7


-------
Figure 5 below shows a map of the 8-hour GO design values and Figure 6 shows a map of the 1-hour GO design values at
U.S. ambient air monitoring sites based on data from the 2020-2021 period. There were two sites in the Portland, OR area
and one site in Puerto Rico with design values exceeding the 8-hour GO NAAQS, and the Puerto Rico site also exceeded the
1-hour GO NAAQS. The high values in Portland, OR were caused by smoke from wildfires in 2020, while it is unclear what
caused the high concentrations in Puerto Rico. Nearly all other sites in the U.S. were well below the NAAQS, with design
values generally below 3 ppm for the 8-hour GO NAAQS and below 5 ppm for the 1-hour GO NAAQS.

• 0.0 - 3 ppm (255 sites) O 9.1 - 15 ppm (2 sites)
O 3.1-6 ppm (5 sites) • 15.1 - 29.7 ppm (1 sites)

Figure 5: 8-hour GO design values in ppm for the 2020-2021 period. Source: AQS.

8


-------
• 0.1 - 5 ppm (255 sites) O 10.1 - 20 ppm (3 sites)

O 5.1 - 10 ppm (5 sites) • 35.1 - 41.6 ppm (1 sites)

Figure 6: 1-hour GO design values in ppm for the 2020-2021 period. Source: AQS.

9


-------
Figure 7 below shows a map of the site-level trends in the 8-hour GO design values and Figure 8 shows a map of the
site-level trends in the 1-hour GO design values at U.S. monitoring sites having valid design values in at least 17 years from
2000 through 2021. The trends were computed using the Thiel-Sen estimator, and tests for significance were computed using
the Mann-Kendall test. From these figures it is apparent that GO concentrations have been decreasing at nearly all sites in
the U.S. One site in Puerto Rico had an increasing trend in the 1-hour design values, but the same site had a decreasing
trend in the 8-hour design values.

^ Decreasing > 0.1 ppm/yr (72 sites) o No Significant Trend (15 sites)
V Decreasing < 0.1 ppm/yr (74 sites)

Figure 7: Site-level trends in 8-hour GO design values based on data from 2000 through 2021. Source: AQS, trends
computed using R statistical software.

10


-------
^ Decreasing > 0.2 ppm/yr (53 sites) o No Significant Trend (16 sites)

V Decreasing < 0.2 ppm/yr (91 sites) A Increasing > 0.2 ppm/yr (1 sites)

Figure 8: Site-level trends in 1-hour GO design values based on data from 2000 through 2021. Source: AQS, trends
computed using R statistical software

11


-------
Figure 9 below shows the national trends in the 8-hour and 1-hour co design values based on the 161 sites shown in
Figure 7 and Figure 8, respectively. The national median of the 8-hour design values has decreased by 65% from about 3.7
ppm in 2000 to about 1.3 ppm in 2021. The national median of the 1-hour design values has decreased by 67% from 5.7 ppm
in 2000 to 2 ppm in 2021.

10th/90th Percentile 1-hour DV
Median 1-hour DV
10th/90th Percentile 8-hour DV

E

Q.
Q.

£

£=

O)

'(/)

(D

O CD

o

O

o
o
o
CM

o
o
CM

CM
o
o
CM

CO
o
o
CM

o
o
CM

LO

o
o
CM

CD
o
o
CM

h-
o
o
CM

00

o
o
CM

CD

o
o
CM

o
CM

o
CM

o
CM

o
CM

o
C\J

o
CM

o
CM

o
C\J

o
CM

o
C\J

o
CM
o
CM

C\J
o
CM

Figure 9: National trends in CO design values in ppm, 2000 to 2021. Source: AQS.

Additional Resources

Carbon Monoxide (GO) Pollution

Reviewing National Ambient Air Quality Standards (NAAQS): Scientific and Technical Information
Air Emissions Inventories

Ambient Monitoring Technology Information Center (AMTIG)

Air Quality Design Values

National Air Quality: Status and Trends of Key Air Pollutants

Air Data: Air Quality Data Collected at Outdoor Monitors Across the U.S.

12


-------