Long-Term Stewardship Assessment Report

Hoover Treated Wood Products, Inc.

EPA ID #: VAD988190021

Milford, Virginia 22514

Assessment Date: September 21, 2022

Introduction: Long-term stewardship (LTS) refers to the activities necessary to ensure that
engineering controls (ECs) are maintained and that institutional controls (ICs) continue to be enforced.
The purpose of the EPA Region 3 LTS program is to periodically assess the efficacy of the
implemented remedies (i.e., ECs and ICs) and to update the community on the status of the RCRA
Corrective Action facilities. The assessment is conducted in twofold, which consists of a record review
and a field inspection, to ensure that the remedies are implemented and maintained in accordance with
the final decision.

Facility Background: Hoover Treated Wood Products, Inc. (Hoover) operates a wood preserving
facility located at 18315 House Road in Milford, Caroline County, Virginia at approximate latitude
38° 00' 32" North and longitude 77° 21' 59" West. Hoover owns approximately 53.48 acres of land at
this site. Approximately 65% of the property is developed. The Hoover site is generally considered the
developed portion of the property only. The site is bounded on the south by a swamp with oxbow lake
features, on the north by a low lying marshy intermittent drainage way and American Stone Mix Inc.,
to the northwest by Jones Chemical Inc., to the east by undeveloped woodland, to the south by
woodland and swamp followed by farmland and a residence, and to the west by Keller Ladders, Inc.

Wood is preserved at the Hoover facility by pressure treatment with a Chromated Copper Arsenate
solution (CCA) and other wood preserving solutions, as well as interior and exterior fire retardants.
Alkaline Copper Quat (ACQ) is also used as a wood preserving chemical at the facility. ACQ is a wood
preservative that has been developed in recent years as an alternative to CCA. The fungicides and
insecticides in ACQ consist of copper oxide (approximately 67%) and a quaternary ammonium
compound (approximately 33%). Interior and exterior fire retardants used at the facility include Pyro-
Guard® and Exterior Fire-X®. Pyro-Guard is pressure-impregnated, interior fire-retardant treated
lumber and plywood for enclosed structural applications that is generally composed of boron, nitrogen,
phosphorus, and sodium compounds. Exterior Fire-X is pressure-impregnated fire-retardant lumber
and plywood that provides tested fire protection for applications directly exposed to the weather or
high humidity, outdoors as well as indoors. Exterior Fire-X is generally composed of polymerized resin
of nitrogen-phosphorus complex.

Page 1


-------
Current Site Status: In July 2016, the facility's Hazardous Waste Management Permit (Permit) was
modified to incorporate a final remedy detailed in a Statement of Basis (SB) developed by the Virginia
Department of Environmental Quality (DEQ), dated May 13, 2016, which consists of the following
components: 1) continue the groundwater monitoring program and operation of existing groundwater
extraction system, 2) continue to comply with the Facility's Corrective Measures Implementation
Workplan, dated December 8, 2014, and 3) maintain compliance with institutional controls (ICs) in
the form of land use restrictions. The modified Permit became effective on July 8, 2016 and represents
Remedy Selection and Remedy Construction Complete determinations in accordance with the
Corrective Action process.

Long-term Stewardship Site Visit: On September 21, 2022, EPA conducted a long-term stewardship
site visit with Hoover Treated Wood Products, Inc. to discuss and assess the status of the implemented
remedies at the Facility.

The attendees were:

Name

Organization

Email Address

Christine Kimak

EPA Region 3

kimak.christine@epa.gov

Stephanie Houston

Virginia Department of
Environmental Quality

Stephanie.houston@deq.virginia.gov

Mike Rastatter

Hoover Treated Wood Products,
Inc.



Gene Henson

Hoover Treated Wood Products,
Inc.



David Kerschner

KU Resources, Inc.

dkershner@kuresources.com

Institutional Controls (ICs) Status: The Facility must comply with the ICs which will be imposed
by the Facility's Hazardous Waste Management Permit for Site Wide Corrective Action. The
following ICs apply to the Hoover Facility, shown on Figure 1:

Groundwater Use Restriction: Groundwater beneath the property shall not be used for any purposes
except for environmental monitoring and testing, or for non-contact industrial use as may be
approved by EPA subject to the considerations in the Corrective Measures Study until cleanup goals
for groundwater have been met. Any new groundwater wells installed on the property must be
approved by EPA. Groundwater on site is not used for potable purposes.

Residential Land Use Restriction: The Facility property shall not be used for residential purposes or
for children's (under the age of 16) daycare facilities, schools, or playground purposes. The site is
currently being used as a wood preserving facility.

Engineering Controls (ECs) Status:

Groundwater Treatment System: The groundwater extraction system consists of nine recovery wells
(RW-1 through RW-9), nine electric submersible pumps, a vertical storage tank, and cycle and
overfill controls. Extracted groundwater from each well is routed via buried piping to a 15,840-

Page 2


-------
gallon vertical water storage tank located within the bermed area east of the wood treatment plant.
The water held in the storage tank is introduced into the facility process stream. Along with
development water and purge water generated from site assessment and monitoring activities, the
water is used to mix wood treating solutions for generation of product at the Facility. Approximately
1,400 gallons of this water are used at the Facility each day. The latest data suggest that there was
hydraulic control of the groundwater, and it appears that the system is effectively removing arsenic
from groundwater at the Facility via the recovery wells.

Per the Permit and SB, remedial efforts utilizing groundwater extraction to reduce concentrations of
arsenic in groundwater and to provide containment of the dissolved arsenic groundwater plume will
continue. Active remediation will continue until the remedial cleanup goals for arsenic have been met
or until it has been demonstrated that the remedy is no longer effective.

Monitored Natural Attenuation Groundwater Monitoring: The groundwater monitoring program
outlined in the Facility's approved CMI Plan will continue to provide adequate hydraulic control of
arsenic in groundwater and ongoing reductions in arsenic concentrations within the plume, and to
monitor attenuation and/or dissipation of arsenic.

Financial Assurance: The Facility is providing financial assurance for continued groundwater
monitoring and investigation activities required by the Facility's Permit. Updated cost estimates for
DEQ's final decision were required by the Permit and were the basis for financial responsibility for
the implementation and operation and maintenance of the final remedy.

Reporting Requirements/Compliance: Hoover submits annual groundwater monitoring reports,
which includes the Operation and Maintenance requirements associated with the groundwater
extraction system. The latest Annual Groundwater Monitoring Report was submitted on April 27,
2022. The Facility is in compliance with activity and use limitations set forth in the Permit. No transfer
of Facility property, change in use of the property, or work that will affect contamination at the property
has been reported.

Mapping: The EPA website map displays the approximate 64-acre Facility boundary. A downloadable
geospatial PDF map is available on EPA's corrective action facility webpage under the "Reports,
Documents and Photographs" section, found here.

Follow-Up Activities: No follow-up activities required.

Conclusions and Recommendations: No institutional or engineering control deficiencies were
identified. EPA has determined that the remedy institutional and engineering controls have been fully
implemented. The remedy remains effective in being protective of human health and the environment.

Page 3


-------
Attachments:

Figure 1: Aerial Map of Hoover Treated Wood Products Facility
Picture 1: Area A
Picture 2: MW-3

Picture 3: Storage Tank Control Panel
Picture 4: Storage Tank
Picture 5: RW-7
Picture 6: RW-2

Attachment 1: Remedy Review and Assessment Questionnaire

Page 4


-------
Figure 1: Aerial Map of Hoover Treated Wood Products Facility



Hoover Treated Wood Products
EPA ID# VAD988190021
18315 House Drive
Milford, VA 22514

Property Boundary

200 400

BSliregl Esni IBi qiWiJ opg


-------
Picture 2: MW-3


-------
Picture 3: Storage Tank Control Panel

Picture 4: Storage Tank


-------
Picture 6: RW-2


-------
Attachment 1

Remedv Review and Assessment Questions:

Yes

No

Notes

• Have the ICs specified in the remedy been fully
implemented? Implementation mechanism in place?

X





• Are there plans to develop or sell the property?



X



• Have all reporting requirements been met?

X





• Is groundwater onsite used for potable purposes?



X



• Is the Facility connected to a public water supply?



X



• Have any new wells been installed at the facility?



X



• Has (active remediation system) been maintained as
necessary?

X





• Have there been recent construction or earth-moving
activities or plans for such?



X



• Is the security fence intact?

X



There is a fence that surrounds
the property, but as per the
Plant Manager it cannot be
considered a security fence.


-------