Reporting emissions on a process rate parameter.

There are emission limits based on process rate parameters. In the ERT the first process parameter will
be determined with the Source Classification Code (SCC). This code is important and describes the
process unit and fuel used. If the process parameter units of measure is in the drop down list for the
SCC, select it.

Facility/Tester Permit/SCC Locations/Methods Regulations Process/APCD Methods cont. Audit/Calibrations Schedule I Reviewers I Attach,

Air Permit Number:
S1 Permitted St;
Permitted Ma
Maximum Nor
Tj get Procei
Operational H
Source Class

f$ SCC/

Target Para

Target Para
Descripl

nfioir

3 Select SCC

(* required fields)

Level 1
Level 2
Level 3
Level 4

QEEB

SCC | Unite I Measure | Materials | Action

10200204

External Combustion Boilers

Industrial

IBituminous Coal

B

Description	

SCC8

UNIT

MEASURE

MATERIAL

ACTION

>

Pulverized Coal: Dry Bottom Tangential

10200226

Lb

Million Btus

Heat

Input



Pulverized Coal: Dry Bottom Tangential

10200226

Lb

Tons

Subbituminous Coa

Burned



Pulverized Coal: Wet Bottom

10200201

Lb

1000 Tons

Bituminous Coal

Burned



Pulverized Coal: Wet Bottom

10200201

Lb

Million Btus

Heat

Input



Pulverized Coal: Wet Bottom

10200201

Lb

Tons

Bituminous Coal

Burned



Pulverized Coal: Wet Bottom

10200221

Lb

1000 Tons

Subbituminous Coa

Burned



Pulverized Coal: Wet Bottom

10200221

Lb

Million Btus

Heat

Input



Pulverized Coal: Wet Bottom

10200221
10200204

Lb
Lb

Tons

1000 Tons

Subbituminous Coa
Bituminous Coal

Burned
Burned



Spreader Stoker



Spreader Stoker

10200204

Lb

Million Btus

Heat

Input



Spreader Stoker

10200204

Lb

Tons

Bituminous Coal

Burned



Spreader Stoker

10200204

mg

Megagrams

Coal

Burned



Spreader Stoker

10200224

Lb

1000 Tons

Subbituminous Coa

Burned



Spreader Stoker

10200224

Lb

Million Btus

Heat

Input



Spreader Stoker

10200224

Lb

Tons

Subbituminous Coa

Burned

*¦

sPage

Next Page

Figure 1. Selecting SCC with process parameter unit of measure.

The SCC process and unit of measure are highlighted in yellow in the ERT.


-------
Facility/Tester Permit/SCC Locations/Methods Regulations Process/APCD Methods cont. Audit/Calibrations Schedule Reviewers Attach.

Air Permit Number:

1 Permitted State Source ID/Name: j
Permitted Maximum Process Rate:
Maximum Normal Operation Process Rate:
Target Process Rate for Testing:
Operational Hours Per Year:

Source Classification Code:

Select SCC from list

SCC/Desc.: * [l

External Combustion Boilers - Industrial - Bituminous Coal - Spreader
Stoker

Target Parameter: |Bituminous Coal Burned

Process Rate: |Tons/hr
Pollutant Unit of Measure: |Lb/hr

Target Parameter
Description (if
needed):

(* required fields)

Previous Page	Next Page

Figure 2. Result of SCC selection

Always assign the appropriate SCC for the process.

If the unit of measure that is required by the permit or rule is not in the SCC list, the information can be
added under the Process/APCD tab 6a. of the test plan.


-------
Facility /Tester | Permit/SCC | Locations/Methods | Regulations Process/APCD Methods cont. | Audit/Calibrations | Schedule | Reviewers | Attach^
@ 6a. Enter the process data to be documented during testing. (Required before test data entry)

Add Process

Process Parameter: (click to view/edit w

Process Rate ~

Pollutant Unit T

Measure

Time Unit

Materi*

¦Bituminous Coal BurnedH

Tons/hr

Lb

Tons

/hr

Bituminous

Steam Produced

Pounds/hr

Lb

Poumls

/hr

Steam

JL

0

6b. Enter the process lab data to be documented during testing.

Add Lab

Analysis Required: (click to view/edit)

Units

Comments

7a. Please give a brief description of the source (including control equipment) and attach source or
process flow diagram:

Attach File

7b. Control Devices: (Required before test data entry)

Add Control Device

Location

Contro l Device : (click to view/edit)

Units

Target ValL

Outlet

| T | BAGHOUSE





stack

ELECTROSTATIC PRECIPITATOR





l
-------
rocess Information

Process Parameter: jsteam Produced

NOTE: The Material and the Action become the Process Parameter (as in "Coal Burned")

Process Rate: Tons/hr

NOTE: The Measure and Time Unit become the Process Rate (as in "Tons/hr")
Pollutant Unit:

Lb

Measure:

Emission factor unit numerator; units associated with pollutant emitted (as in "LB" in "LB of N Ox
per tons of coal burned ")

Time Unit:

Tons

/hr

Emission factor unit denominator; units associated
with material processed (as in "TONS" in "LbofNOx
per TONS of coal burned")

Will be the same for
the Process Rate and
Compound Unit

Material:

Steam

Materialprocessed (as in "COAL" in "Lb of NOx per tons of COAL burned")
Action:	-r

Action performed on the materia! (as in "BURNED" in "Lb of NOx per tons of coal BURNED")

Target Value Range: Target Low:
Comments:

0 Target High:

Exit

Save and Exit

Figure 4. Adding process information.

Once this information is added, it needs to be linked to the test data. In the test plan select the
Location/Methods tab. In 2b Method 5 Ib/hr select the Process Rate, parameter Ib/hr of steam
produced (Figure 5). The ERT will now calculate on the emissions tab of the test run data lb of PM/lb of
steam produced (Figure 6). The method 5 run 1 is associated with the process run 1 so the calculations
can be conducted. If the association is not assigned on the Emissions tab, #Error will will be displayed
in the lb/lb of steam produced column.


-------
Facility/Tester Permit/SCC Locations/Methods ^Regulations ' Process/APCD j Methods cont. j Audit/Calibrations J Schedule j Reviewers J Attach.

@ 1. Please enter sampling location information, (all dimensions in inches)

(Required before test data entry)

Add Location

Attach File

Location: (click to view/edit)

. In let/0 utl ~

Total Trave T

Ports ~ Round Duct Diam ~ DuctLe ^ DuctWkf -r Equivalent

T Up Stream Distar T Down S



Outlet

24

4 24

10

1

E

^	(Note: UpStreamDist = Distance from upstream disturbance; DwnStreamDist = Distance from downstream disturbance)

2a. Please provide the following information for each test parameter. (Required before test data entry)

Add Target
Parameters

Location *\

Test Method *\ Target Parameter

Num Test Runs ~

Test Run Duration ~

Comments



stack

Method 1 - 4 Flow rate

3

60







stack

Method 1-4 % H20

3

60







stack

Method 10 Carbon Monoxide

3

60







stack

Method 12 Inorganic Lead

3

60







stack

Method 5 Filterable Particulate

3

60





Record: M < |l of 5 | ~ M



Search

2b. Please select the Emissions Units of Measure for each location.

Add Emissions/Concentrations

Local w\

Method

~I Units of Measure

~ Corre ~

Corrected % ~

Process Rate, Parameter

stack

Method 10

ppm



0

stack

Method 5

grains/dscf



0

stack

Method 5

Ib/hr



0

Pounds/hr of Steam Produced



Record; H

|1 of 3 ~

~I

11 Search





[ Previous Page | | Next Page

Figure 5. Method and Process Rate parameter.


-------
<*' -

ERT v 5 12/3/2015





HOME 1 CREATE EXTERNAL DATA

DATABASE TOOLS



Lowe, T

"^1 Run Data Details





I - li ® IE

1

H|Fox River Paper Mill









Select Location - Method:



Add New Run Data 1

Delete Run Data

Select Run:



1 Change Run Number 1

Change Run Date

Method Setup Header Data Point Data Lab Data

Sampling/Stack Data Results

| Cydone Cut Size Emissions



Associated ^

Method:	RunNuober:	RunDate:	Process Run:

Figure 6. Emissions in units required by the permit.


-------