Reporting emissions on a process rate parameter.
There are emission limits based on process rate parameters. In the ERT the first process parameter will
be determined with the Source Classification Code (SCC). This code is important and describes the
process unit and fuel used. If the process parameter units of measure is in the drop down list for the
SCC, select it.
Facility/Tester Permit/SCC Locations/Methods Regulations Process/APCD Methods cont. Audit/Calibrations Schedule I Reviewers I Attach,
Air Permit Number:
S1 Permitted St;
Permitted Ma
Maximum Nor
Tj get Procei
Operational H
Source Class
f$ SCC/
Target Para
Target Para
Descripl
nfioir
3 Select SCC
(* required fields)
Level 1
Level 2
Level 3
Level 4
QEEB
SCC | Unite I Measure | Materials | Action
10200204
External Combustion Boilers
Industrial
IBituminous Coal
B
Description
SCC8
UNIT
MEASURE
MATERIAL
ACTION
>
Pulverized Coal: Dry Bottom Tangential
10200226
Lb
Million Btus
Heat
Input
Pulverized Coal: Dry Bottom Tangential
10200226
Lb
Tons
Subbituminous Coa
Burned
Pulverized Coal: Wet Bottom
10200201
Lb
1000 Tons
Bituminous Coal
Burned
Pulverized Coal: Wet Bottom
10200201
Lb
Million Btus
Heat
Input
Pulverized Coal: Wet Bottom
10200201
Lb
Tons
Bituminous Coal
Burned
Pulverized Coal: Wet Bottom
10200221
Lb
1000 Tons
Subbituminous Coa
Burned
Pulverized Coal: Wet Bottom
10200221
Lb
Million Btus
Heat
Input
Pulverized Coal: Wet Bottom
10200221
10200204
Lb
Lb
Tons
1000 Tons
Subbituminous Coa
Bituminous Coal
Burned
Burned
Spreader Stoker
Spreader Stoker
10200204
Lb
Million Btus
Heat
Input
Spreader Stoker
10200204
Lb
Tons
Bituminous Coal
Burned
Spreader Stoker
10200204
mg
Megagrams
Coal
Burned
Spreader Stoker
10200224
Lb
1000 Tons
Subbituminous Coa
Burned
Spreader Stoker
10200224
Lb
Million Btus
Heat
Input
Spreader Stoker
10200224
Lb
Tons
Subbituminous Coa
Burned
*¦
sPage
Next Page
Figure 1. Selecting SCC with process parameter unit of measure.
The SCC process and unit of measure are highlighted in yellow in the ERT.
-------
Facility/Tester Permit/SCC Locations/Methods Regulations Process/APCD Methods cont. Audit/Calibrations Schedule Reviewers Attach.
Air Permit Number:
1 Permitted State Source ID/Name: j
Permitted Maximum Process Rate:
Maximum Normal Operation Process Rate:
Target Process Rate for Testing:
Operational Hours Per Year:
Source Classification Code:
Select SCC from list
SCC/Desc.: * [l
External Combustion Boilers - Industrial - Bituminous Coal - Spreader
Stoker
Target Parameter: |Bituminous Coal Burned
Process Rate: |Tons/hr
Pollutant Unit of Measure: |Lb/hr
Target Parameter
Description (if
needed):
(* required fields)
Previous Page Next Page
Figure 2. Result of SCC selection
Always assign the appropriate SCC for the process.
If the unit of measure that is required by the permit or rule is not in the SCC list, the information can be
added under the Process/APCD tab 6a. of the test plan.
-------
Facility /Tester | Permit/SCC | Locations/Methods | Regulations Process/APCD Methods cont. | Audit/Calibrations | Schedule | Reviewers | Attach^
@ 6a. Enter the process data to be documented during testing. (Required before test data entry)
Add Process
Process Parameter: (click to view/edit w
Process Rate ~
Pollutant Unit T
Measure
Time Unit
Materi*
¦Bituminous Coal BurnedH
Tons/hr
Lb
Tons
/hr
Bituminous
Steam Produced
Pounds/hr
Lb
Poumls
/hr
Steam
JL
0
6b. Enter the process lab data to be documented during testing.
Add Lab
Analysis Required: (click to view/edit)
Units
Comments
7a. Please give a brief description of the source (including control equipment) and attach source or
process flow diagram:
Attach File
7b. Control Devices: (Required before test data entry)
Add Control Device
Location
Contro l Device : (click to view/edit)
Units
Target ValL
Outlet
| T | BAGHOUSE
stack
ELECTROSTATIC PRECIPITATOR
l
-------
rocess Information
Process Parameter: jsteam Produced
NOTE: The Material and the Action become the Process Parameter (as in "Coal Burned")
Process Rate: Tons/hr
NOTE: The Measure and Time Unit become the Process Rate (as in "Tons/hr")
Pollutant Unit:
Lb
Measure:
Emission factor unit numerator; units associated with pollutant emitted (as in "LB" in "LB of N Ox
per tons of coal burned ")
Time Unit:
Tons
/hr
Emission factor unit denominator; units associated
with material processed (as in "TONS" in "LbofNOx
per TONS of coal burned")
Will be the same for
the Process Rate and
Compound Unit
Material:
Steam
Materialprocessed (as in "COAL" in "Lb of NOx per tons of COAL burned")
Action: -r
Action performed on the materia! (as in "BURNED" in "Lb of NOx per tons of coal BURNED")
Target Value Range: Target Low:
Comments:
0 Target High:
Exit
Save and Exit
Figure 4. Adding process information.
Once this information is added, it needs to be linked to the test data. In the test plan select the
Location/Methods tab. In 2b Method 5 Ib/hr select the Process Rate, parameter Ib/hr of steam
produced (Figure 5). The ERT will now calculate on the emissions tab of the test run data lb of PM/lb of
steam produced (Figure 6). The method 5 run 1 is associated with the process run 1 so the calculations
can be conducted. If the association is not assigned on the Emissions tab, #Error will will be displayed
in the lb/lb of steam produced column.
-------
Facility/Tester Permit/SCC Locations/Methods ^Regulations ' Process/APCD j Methods cont. j Audit/Calibrations J Schedule j Reviewers J Attach.
@ 1. Please enter sampling location information, (all dimensions in inches)
(Required before test data entry)
Add Location
Attach File
Location: (click to view/edit)
. In let/0 utl ~
Total Trave T
Ports ~ Round Duct Diam ~ DuctLe ^ DuctWkf -r Equivalent
T Up Stream Distar T Down S
Outlet
24
4 24
10
1
E
^ (Note: UpStreamDist = Distance from upstream disturbance; DwnStreamDist = Distance from downstream disturbance)
2a. Please provide the following information for each test parameter. (Required before test data entry)
Add Target
Parameters
Location *\
Test Method *\ Target Parameter
Num Test Runs ~
Test Run Duration ~
Comments
stack
Method 1 - 4 Flow rate
3
60
stack
Method 1-4 % H20
3
60
stack
Method 10 Carbon Monoxide
3
60
stack
Method 12 Inorganic Lead
3
60
stack
Method 5 Filterable Particulate
3
60
Record: M < |l of 5 | ~ M
Search
2b. Please select the Emissions Units of Measure for each location.
Add Emissions/Concentrations
Local w\
Method
~I Units of Measure
~ Corre ~
Corrected % ~
Process Rate, Parameter
stack
Method 10
ppm
0
stack
Method 5
grains/dscf
0
stack
Method 5
Ib/hr
0
Pounds/hr of Steam Produced
Record; H
|1 of 3 ~
~I
11 Search
[ Previous Page | | Next Page
Figure 5. Method and Process Rate parameter.
-------
<*' -
ERT v 5 12/3/2015
HOME 1 CREATE EXTERNAL DATA
DATABASE TOOLS
Lowe, T
"^1 Run Data Details
I - li ® IE
1
H|Fox River Paper Mill
Select Location - Method:
Add New Run Data 1
Delete Run Data
Select Run:
1 Change Run Number 1
Change Run Date
Method Setup Header Data Point Data Lab Data
Sampling/Stack Data Results
| Cydone Cut Size Emissions
Associated ^
Method: RunNuober: RunDate: Process Run:
Figure 6. Emissions in units required by the permit.
------- |