OMB 2060-0580
Expiration Date: 01/31/2025

Combined Air Emissions Reporting System

(CAERS) Version 3
User's Guide Version 3.2

Last updated: 03/30/2022


-------
OMB 2060-0580
Expiration Date: 01/31/2025

About CAERS and the Paperwork Reduction Act

CAERS supports both emissions data collection from owners/operators of facilities to state, local, and
tribal (SLT) agencies as well as collection from SLT agencies to the EPA. Data collection by a SLT from
owner/operators is subject to the regulations of the SLT agency. Historically, these data collections have
been done by SLTs prior to EPA's creation of the Air Emissions Reporting Rule (AERR; 40 CFR Part 51,
Subpart A). The AERR built on the Consolidated Emissions Reporting Requirements (CERR), which was
created to consolidate several emissions reporting requirements for SLTs to the EPA.

Given this history, the burden included with the Information Collection Request for the AERR covers the
burden for SLTs to report to the EPA. The burden statement below covers that part of the emission data
collection process.

Burden Statement

This collection of information is approved by OMB under the Paperwork Reduction Act, 44 U.S.C. 3501
et seq. (OMB Control No. 2060-0580). Responses to this collection of information are mandatory (40 CFR
§ 51.15) and include voluntary aspects for reporting (40 CFR § 51.15 paragraphs (a)(2)-(4)). A federal
agency may not conduct or sponsor, and a person is not required to respond to, a collection of
information unless it displays a currently valid OMB control number. The public reporting and
recordkeeping burden for this collection of the point source portion of the AERR information is
estimated to range from 50 -190 hours per response. Send comments on the Agency's need for this
information, the accuracy of the provided burden estimates and any suggested methods for minimizing
respondent burden to the Regulatory Support Division Director, U.S. Environmental Protection Agency
(2821T), 1200 Pennsylvania Ave., NW, Washington, D.C. 20460. Include the OMB control number in any
correspondence. Do not send the completed form to this address.

ii


-------
Table of Contents

About CAERS and the Paperwork Reduction Act	ii

Burden Statement	ii

1	Introduction	1

1.1	Introduction to CAERS	1

1.2	Highlights of CAERS Features	1

1.3	Software Requirements for CAERS	2

2	Initial Pre-Reporting Steps	2

2.1	Determine Your Role as Preparer or Certifier	2

2.2	Option for Reporting TRI-bound Air Toxics Data	3

2.3	Timing of Your NEI and TRI Submissions	3

3	Registration	4

3.1	Registration in CDX	4

3.2	Add CAERS to your CDX Account	5

3.3	Gain Access to CAERS and your Facility	13

3.4	Opt in-Process for Facilities Reporting to GADNR	15

3.4.1	If the Facility was Operating	16

3.4.1.1	Facilities Bellow All Pollutant Thresholds	17

3.4.1.2	Facilities Above at Least One Pollutant Threshold	19

3.4.2	If the Facility was Temporarily or Permanently Shut Down	20

4	Reporting Emissions and Facility Information via the User Interface	20

4.1	Navigating the User Interface	20

4.1.1	General Description of User Interface Features	20

4.1.2	Emissions Reports Page	21

4.1.3	Report Summary Page	23

4.1.4	Including an Attachment in Your Report	25

4.2	Facility Inventory	26

4.2.1	Facility Information	26

4.2.2	Emission Units Page	29

4.2.3	Release Points Page	32

4.2.4	Control Devices Page	35

4.2.5	Control Paths Page	40

4.3	Emissions inventory	45

4.3.1	Units	45

4.3.2	Processes	45

iii


-------
4.3.2.1	Associating a Process to a Release Point	50

4.3.2.2	Entering and Calculating Emissions	51

5	Reporting Emissions and Facility Information Using Bulk Upload	54

5.1	The Bulk Upload Excel Template	54

5.2	Bulk Upload Steps	59

5.3	JSON	60

6	Reporting Emissions Using Bulk Entry	60

7	Performing Quality Checks	62

8	Certifying and Submitting to your State, Local, or Tribal (SLT) Authority	65

8.1	Certification and Submission of Report	66

8.2	Correcting Reports with Errors	67

8.3	Disputing or Repudiating a Report	67

8.4	CDX Submission History	67

9	Submission Approval	68

10	Using Data Reported in CAERSfor a TRI-MEweb submission	68

11	Where to Go for Help	71

11.1	Help with the CAERS application itself	72

11.2	Help with programmatic questions:	72

Appendix A Understanding Controls	A-l

Appendix B Types of Fugitive Release Points	B-l

Appendix C Additional Resources	C-l

Appendix D CAERS Submission Checklist	D-l

Appendix E Monthly Reporting for DOEE Facilities	E-l

List of Figures

Figure 3-1. CDX Login Screen	5

Figure 3-2. CDX Terms and Conditions	5

Figure 3-3. CDX Program Service Page	6

Figure 3-4. Role Selection Screen	6

Figure 3-5. User Information Data Entry	7

Figure 3-6. Selection of Organization	8

Figure 3-7. Organization Information Data Entry	8

Figure 3-8. Confirmation Code Entry	9

Figure 3-9. CDX Lexis Nexis Identity Verification	9

Figure 3-10. CDX Lexis Nexis Identity Verification	10

Figure 3-11. Verification Questions	11

Figure 3-12. CDX Electronic Signature Agreement	11

iv


-------
Figure 3-13. eSignature Screen	12

Figure 3-14. MyCDX Page	12

Figure 3-15. "My Facilities" Page in CAERS	13

Figure 3-16. Facility Search in CAERS	14

Figure 3-17. Request Access to Selected Facility	14

Figure 3-18. "My Facilities" Page Listing Facilities	15

Figure 3-19. Starting the GADNR Opt-in/Opt-out Process	16

Figure 3-20. Selecting Operating Status for GADNR Facilities	17

Figure 3-21. Potential to Emit Threshold Questionnaire for GADNR Facilities	17

Figure 3-22. Report Summary Page for a Facility that Opted Out	18

Figure 3-23. Attaching the Thresholds Analysis for GADNR Facilities that Opted Out	19

Figure 3-24. Certify and Submit for GADNR Facilities that Opted Out	19

Figure 4-1. Begin Emissions Report	22

Figure 4-2. Emissions Report Page	23

Figure 4-3. Facility Report Summary Page	24

Figure 4-4. Including an Attachment	25

Figure 4-5. Facility Information Page	26

Figure 4-6. Editing Facility Information	27

Figure 4-7. Edit Facility NAICS codes	28

Figure 4-8. Find and Select NAICS Code	28

Figure 4-9. Enter Facility Contact Information	29

Figure 4-10. Emissions Units Page	30

Figure 4-11. Adding a New Unit	30

Figure 4-12. Example of a Page for a Specific Unit	31

Figure 4-13. Editing a Unit	31

Figure 4-14. Release Points Page	33

Figure 4-15. Adding a New Release Point	34

Figure 4-16. Example of a Page for a Release Point	35

Figure 4-17. Editing a Release Point	35

Figure 4-18. Control Devices Page	36

Figure 4-19. Adding a New Control	37

Figure 4-20. Example of a Page for a Control Device	37

Figure 4-21. Editing a Control Device	38

Figure 4-22. Associating a Pollutant and Control Efficiency to a Control	39

Figure 4-23. Control Paths Page	41

Figure 4-24. Adding a New Path	41

Figure 4-25. Example of a Page for a Control Path	42

Figure 4-26. Editing a Path	42

Figure 4-27. Adding a Path Assignment	43

Figure 4-28. Example of a Facility with Complex Controls	44

Figure 4-29. Adding a New Process	46

Figure 4-30. SCC Search	47

Figure 4-31. Example of a Page for a Process	48

Figure 4-32. Editing a Process	49

Figure 4-33. Release Point Apportionment	50

Figure 4-34. Adding a New Pollutant	52

Figure 4-35. Selecting a Calculation Method	53

Figure 4-36. Using EPA Emission Factor Alternative	54

v


-------
Figure 5-1. Example of Bulk Upload Template Worksheet	59

Figure 5-2. JSON Upload Option in CAERS	60

Figure 6-1. Bulk Entry Process Information Tab	61

Figure 6-2. Bulk Entry Emissions Information Tab	62

Figure 7-1. Quality Review Page	63

Figure 7-2. Correcting an Error	64

Figure 7-3. Completing Quality Checks	65

Figure 8-1. Submission Review Screen	66

Figure 8-2. Submission Certification	66

Figure 8-3. CDX Submission History Page	68

Figure 10-1. Example of Section 5 Form R Screen in TRI-MEweb	69

Figure 10-2. Example of "NEI Data Available" Screen	70

Figure 10-3. Example NEI Data Availability Pop-Up Window	70

Figure 10-4. Example Pop-Up Window for Comment	71

Figure 11-1. Help Screen in CAERS	72

Figure A. 1. Example of a Facility with No Controls	A-2

Figure A. 2. Example of a Facility with a Single Control	A-3

Figure A. 3. Example of a Facility with Controls in Series	A-4

Figure A. 4. Path Assignments for a Facility with Controls in Series	A-5

Figure A. 5. Example of Complex Controls	A-6

Figure A. 6. Path Assignment for a Facility with Complex Controls	A-7

Figure A. 7. Planer Mill Cyclofilter Path Assignment	A-8

Figure A. 8. Example for Controls Working Alternately	A-9

Figure A. 9. Path Assignment for Controls Working Alternately	A-10

Figure A. 10. Flow of Uncontrolled Emissions	A-ll

Figure B. 1. Graphical Representation of Current "Area" Fugitive Release Points	B-l

Figure B. 2. Graphical Representation of 2-Dimensional Fugitive Release Points	B-2

Figure B. 3. Graphical Representation of 3-Dimensional Fugitive Release Points	B-2

List of Tables

Table 4-1. Example of Data Entry for Controls in Sequence for Path 1	44

Table 4-2. Example of Data Entry for an Assignment including a Control and a Path Running in Parallel
for Path 2	44

Table A. 1. Example Associations for a Facility with No Controls	A-2

Table A. 2. Example Associations with No Controls	A-3

Table A. 3. Example Path Data for a Facility with a Single Control	A-3

Table A. 4. Example Associations for a Facility with a Single Control	A-4

Table A. 5. Example Path Data for a Facility with Controls in Series	A-5

Table A. 6. Example Associations for a Facility with Controls in Series	A-5

Table A. 7. Example Path Data for a Facility with Complex Controls	A-7

Table A. 8. Example Associations for a Facility with Complex Controls	A-7

vi


-------
Table A. 9. Path Data for Planer Mill Cyclofilter	A-8

Table A. 10. Associations for Planer Mill Cyclofilter	A-8

Table A. 11. Path Data for Controls Working Alternately	A-10

Table A. 12. Associations for Controls Working Alternately	A-10

Table C. 1. Default Heat Values for Fuels	C-l

Table C. 2. List of Simple Unit of Measure Conversions in CAERS	C-4

vii


-------
1 Introduction

1.1	Introduction to CAERS

The Combined Air Emissions Reporting System (CAERS) is an application that allows industry from

subscribed State, Local, or Tribal authorities (or SLTs) to report their air emissions, so that you can:

•	Meet specific SLT air emissions reporting requirements given individual SLT regulations.

•	Report annual or triennial emissions to meet the requirements of the U.S. EPA's Air Emissions
Reporting Rule (AERR), as per the Code of Federal Regulations (or CFR) 40, Part 51.

•	And, optionally, get a head start on reporting your facility's toxics air emissions to the U.S. EPA's
Toxics Release Inventory (TRI), as per 40 CFR Part 372.

You should check with your SLT to determine if you meet the criteria for annual reporting.

1.2	Highlights of CAERS Features

The following basic features will help users navigate CAERS. By becoming familiar with these

features, you will have a smoother and less time-consuming reporting experience. You should

also consult the Checklist (Appendix D) at the end of this user guide to assist you in your

submission.

1.	Previously reported data prepopulated in a current inventory year report, as a starting point.

2.	All pages look, feel, and function in a consistent predictable way.

3.	All required fields are marked with an symbol, and a "?" symbol next to data fields
provides a pop-up box with its definition and examples.

4.	Three options for data entry:

a.	User interface - for users with few changes to a previous year report, and with
different kinds of changes.

b.	Bulk entry - for users with a few changes to their annual throughput and emissions,
and with few to no changes to their facility inventory.

c.	Bulk upload - for users with a large number of changes, and/or with a variety of
changes from a previous year report, this includes new and/or large facilities with no
previous reporting history who will want to start a brand new report.

i.	Via excel template - for users who would like to work with excel

ii.	Via JSON upload - for users who would like to send data directly from their
custom systems.

5.	Ability to include attachments: Your SLT may require you to provide supplemental
information to your estimates such as detailed calculations in a spreadsheet or word
document.

6.	Bulk download: You will be able to download your previous year report in the excel template
you will need for bulk upload. This will allow you to make the relevant changes directly to the
template.

7.	Ability to download summary reports: You can obtain a summary of your submission in an
excel file (different from the bulk download described above).

8.	Use of toxics air pollutants and hazardous air pollutants (HAPs) reported to CAERS for Toxics
Release Inventory (TRI) reporting: When using the calculation features and/or uploading
calculations for toxics emissions in CAERS, CAERS will aggregate toxics emissions for the
facility, and leave that data ready for TRI-MEweb to pick up so it can be used for that facility's
air emissions reporting.

1


-------
9. A "Report History" page: major activities from reporters and certifiers such as attachments,
certification, and submission of the report are recorded.

1.3 Software Requirements for CAERS
To use the CAER system, you will need:

•	Internet browser and connectivity: This should be a recent version of any internet
browser such as Chrome, Explorer, Edge, or Firefox. Your internet connectivity will
determine how fast data can be uploaded, as will the amount of data you are uploading
at one time.

•	Microsoft Excel: Bulk uploads will be in "XLSX" format, and Excel 2013 or later is
required.

2 Initial Pre-Reporting Steps

2.1 Determine Your Role as Preparer or Certifier

Your first step will be to determine if you are a preparer or certifier as follows:

You are a Preparer if you are authorized to prepare an emissions report for National Emissions Inventory

(NEI) and/or Toxics Release Inventory (TRI) data for a given facility. You may be a consultant, or a staff

person for the company owning the facility, for example. Note that:

•	There may be more than one Preparer for a facility and that facility is associated with each
Preparer's account.

•	There may be a single Preparer for more than one facility, and all those facilities are associated
with that Preparer's account.

•	A Preparer cannot sign and submit the report like a Certifier can.

You are an NEI Certifier if you are authorized to sign the emissions report on behalf of the facility to

meet your legal obligation for reporting to your State, Local, or Tribal authority (SLT). Note that:

•	The Certifier can do everything a Preparer does in the System. Therefore, a Certifier who is also
the Preparer for a facility only needs to register as a Certifier for that facility and does not
require an additional Preparer account.

•	There may be only one Certifier for a facility. Only one individual can sign the report for that
facility. You should consult your SLT to determine who from the facility should be the certifier.

•	There may be a single Certifier for more than one facility (multiple facilities associated with the
certifier account). However, your SLT may have additional limitations to those the system
allows, so you should check with your SLT for specific instructions.

If your facility does not submit toxics air emissions data to TRI-MEweb, you may skip to Section 3.

•	If your facility also submits air toxics data to TRI-MEweb, and your facility will use shared toxics
data reported to CAERS in the TRI reporting (as per sections 2.2 and 2.3), you should note the
following: TRI data is certified in TRI-MEweb, not CAERS. However, when the NEI Certifier
certifies their annual report in CAERS, they will also be signaling to the system that reporting is
complete and that shared data is ready to be made available to TRI-MEweb. So long as a report
is still in progress, CAERS will not make the data available for TRI-MEweb pick up. Furthermore,
TRI bound data will be certified in TRI-MEweb, not CAERS. The NEI Certifier may not be the
same person as the TRI certifier so NEI and TRI certifiers may want to coordinate amongst

2


-------
themselves to ensure they are reporting data to CAERS appropriately. Please direct any
questions about this to caer@epa.gov.

2.2	Option for Reporting TRI-bound Air Toxics Data

CAERS has an optional feature that allows you to get a jump start on air toxics emissions reporting
for your facility. You can enter air toxics/HAP data in CAERS in conjunction with your NEI reporting.
When you are finished, CAERS will then add toxics data up to your facility total and leave that data
available for TRI-MEweb to pick up and prepopulate your air toxics report.

Regulations do not require your report to be reviewed by your SLT for your toxics data to be made
available for TRI reporting. Additionally, your SLT may not require you to report your facility's air
toxics/HAP emissions through CAERS. However, we are encouraging facilities to submit HAPS data at
the process level in CAERS for the following reasons:

•	You'll be able to enter this data and take advantage of the CAERS aggregating air toxics data to
the facility total.

•	Having your SLT review your criteria pollutant data before your data gets to TRI-MEweb gives
you the opportunity to correct any related toxics data. For example, assume your SLT finds an
error with throughput for a unit/process affecting your facility's CO and NOX emissions, that is
also affecting your VOC calculations. As you correct that throughput, all affected emissions are
corrected as well.

•	If no HAPS are reported for the facility, then EPA estimates these emissions from your criteria
emissions data via HAP augmentation calculations. These estimates may not be as accurate as
your own data. By submitting your own HAPs emissions at process level in CAERS, you are in
charge of your data.

•	You should consult your SLT to determine if you are required to submit HAPS data to comply
with SLT requirements.

2.3	Timing of Your NEI and TRI Submissions

CAERS will add up all shared toxics/HAP emissions entered and calculated at the unit/process
level, and make those totals available to you in TRI-MEweb (see Section 10). The goal is for reporters to
save time in doing calculations separately for each program when common or shared input data (e.g.
throughput, emissions) entered for one program can be used for reporting to another program, in this
case TRI reporting. Therefore, a reporter should create the CAERS emissions report leaving time for the
submission to take place before the SLT submission deadline, as well as the TRI deadline of July 1st. TRI
data submissions do not require review by your SLT authority and are picked up by TRI-MEweb by the
submission deadline. A submission that, upon SLT review, requires edits after that date, will be updated
accordingly for submission to NEI. However, any toxics data affected by such edits will be updated in
TRI-MEweb at a later date. Furthermore, you will also want to account for your SLT's submission
deadline. For example, GADNR El deadline is June 30th of each year.

Finally, it is important to leave time in case issues come up that require intervention by the help desk,
SLT, or EPA staff to resolve. Were we to find any glitches in the software, those will take time to resolve
as well. Therefore, we recommend that you:

•	Register as Preparer or Certifier as soon as you know your role in the process.

o If you are already registered as Preparer/Certifier for a facility from last year's

submission, you do not need to re-register, but you should follow any additional steps
your SLT may require.

3


-------
o If staff changes:

¦	For new GADNR preparers and certifiers: go to GECO to register first, then
proceed to CDX to register only after you have gone through the steps in GECO.

¦	For new non-GDNR SLT preparers and certifiers: please notify your SLT
immediately with the name, email address, mailing address and phone number
of the new staff person. Then, new staff should register to CDX immediately to
start and/or continue the report. You should consult with your SLT, as they may
have additional SLT specific verification steps to complete the process as well.

¦	For preparers and certifiers that will no longer be working on a facility's reports,
please let your SLT know as soon as possible so your link to the facility can be
removed promptly. You should consult with your SLT, as they may have
additional SLT specific verification steps to complete the process as well.

•	Coordinate your NEI and TRI reporters so that you start your report no later than one month
before the first program deadline you are facing.

•	Complete your report no later than two weeks before your submission deadline, to allow for
unforeseen circumstances that might delay your emissions report.

For example, given that GADNR's submission deadline is June 30th, it is best for the facility to submit its
emissions inventory through CAERS at least two weeks before that deadline to allow GADNR Reviewer's
advanced QA reviewing process.

Once your SLT has reviewed your report, it will then send that report to EPA in two steps (first facility
information, second throughput and emissions data). While every effort has been made to provide
preparers with quality assurance checks that will help you submit the highest quality data, both your SLT
staff and EPA's Emissions Inventory System (EIS) may present additional checks (either new, or checks
that are not possible to include in CAERS given their nature). These checks may require you to make
corrections to your report after you have certified it. In that case your SLT will return your report for
revisions. These revisions usually take place in the Fall. To avoid some of these issues, we encourage
you to review the "Additional Considerations" sections after each section and chapter.

3 Registration

3.1 Registration in CDX

In order to enter CAERS, you will need to be registered in EPA's Central Data Exchange (CDX). If
you already have a CDX account but have not registered to use CAERS, go to section 3.2. If you are new
to CDX, click on the "Register with CDX" button (Figure 3-1). You will be directed to the Terms and
Conditions screen for CDX registration (Figure 3-2). After reading these, check the box confirming that
you are the registrant and click "Proceed" at the bottom left of your screen.

4


-------
Figure 3-1. CDX Login Screen

: ho-w I Cftm Om C«h» x
CO * cd>*p*-gov

) TStliMwmUM

./Hh/i- G Zmud *Tht vffMtt. 0 N««T«t H (}i2wwtsdl • pqm- 2 — CcdtoI ft- v>

fl o » 4

'vmhGi « s»tu»*i Gm *nd M-

CD)fc Central Data Exchange

Log in to CDX

User ID

Welcome

Welcome to the Environmental Protection Agency (EPA) Central Data Exchange (CDX) - the Agency's electronic reporting site. The
Central Data Exchange concept has been defined as a central point which supplements EPA reporting systems by performing new
and existing functions for receiving legally acceptable data In various formats, including consolidated and Integrated data.

Warning Notice and Privacy Policy

warning Nonet

In proceeding and accessing U.S. Government information and information systems, you acknowledge that you fully understand and consent to
all of the following:

1.	you are accessing U.S. Government information and information systems that are provided for official U.S. Government purposes only,

2.	unauthorized access to or unauthorized use of U-S Government informatnn or information systems is subiect to cnmmal, civil.

Figure 3-2. CDX Terms and Conditions

vvEPA

United States Environmental Protection Agency

Home About Recent Announcements Terms and Conditions FAQ Help Virtual Assistant

CDX? Terms and Conditions

a Contact Us

The access and use of CDX Registration for the electronic submittal of environmental information require the creation of a user
ID and password that I must maintain and keep confidential. I will review the following steps concerning the creation and
maintenance of a user ID and password.

Warning Notice

In proceeding and accessing U.S. Government information and information systems, you acknowledge that you fully
understand and consent to all of the following:

1.	you are accessing U.S. Government information and information systems that are provided for official U.S. Government
purposes only;

2.	unauthorized access to or unauthorized use of U.S. Government information or information systems is subject to criminal,
civil, administrative, or other lawful action;

3.2 Add CAERS to your CDX Account

If you are both an authorized Certifier and Preparer, you do not need to go through this process
twice. Instead, just register as Certifier in CAERS once you are in. Once you have accepted terms and

5


-------
conditions, you will be taken to the Program Services page. You can search "CAER: Combined Air
Emissions Reporting" from the list, or you can type it in the search list as shown in Figure 3-3.

Figure 3-3. CDX Program Service Page

CDX; Edit Account Profile

3. Organization Information

Begin typing a program service name or related keywords to filter the list of available services (e.g., air quality system, AQS, or
Clean Air Act).

Active Program Services List

ARCS: Aircraft Reporting and Compliance System

CAER: Combined Air Emissions Reporting
CDRsTconsennJeCTe^eporTing System
CEDRI: Compliance and Emissions Data Reporting Interface
CSPP: Submissions for Chemical Safety and Pesticide Programs
eDisdosure: Voluntary Disclosure System

Figure 3-4, Role Selection Screen

&EPA

United States Environmental Protection Agency

Home About Recent Announcements Terms and Conditions FAQ Help Virtual Assistant

CDX- Edit Account Profile

¦ Contact Us
Looped in as JSMiTH

3. Organization Information

Registration Information

Program Service
Role

Combined Air Emissions Reporting
Not selected

Select a role from the drop down list and provide any required additional information, if applicable.
Select Role

CDX Hdp Desk: 888 890 1995 | (970) 494 SS00 for International eaten
EPA Home Privacy and Securrfy No<>ce > i!W|	About CDX I Ffrqurntty Asked Qwrrfwm | Term* and Conrfftiom | Contact tM

6


-------
You will be taken to the role access screen where you can choose your role as Preparer or NEI Certifier,
as shown in Figure 3-4. Remember that if you are both Preparer and NEI Certifier, you only need to
register as Certifier. You will only need one NEI Certifier account if you are handling both roles.

After selecting your role click on "Request Role Access". This will take you through a few screens where
you will enter information about yourself, and your organization. On the User and Organization screen
(Figure 3-5) complete the User Information section, including your preferred User ID, password, and CDX
security questions and answers. Make sure to follow all instructions that are provided, including the
identity authentication questions asked. Make sure you remember the answers to those questions. The
authentication questions are an additional step that is needed to ensure that only you, the authorized
staff, can work on and submit the report (see Section 8 for more information).

Figure 3-5. User Information Data Entry

Part 1 (Jsei lrifoim.Uion

Tfv orugtam you are rtsjiwwimj for a:quN;s 
-------
Figure 3-6. Selection of Organization

Part 2: Organization Info

CGI Test

Enter organization or organization ID

Organization ID

Organization Name

Address

City

State

ZIP Code

21947

CGI TEST

12601 FAIRLAKES PKWY

FAIRFAX

VI

22033

Can't find your organization? Use advanced search or

Figure 3-7. Organization Information Data Entry

Part 2: Organization Info
CGI TEST

12601 FAIRLAKES PKWY
FAIRFAX, VI, US
22033

Email *

Re-enter Email *

Phone Number *

Phone Number Ext
Fax Number

john.doe@epa.gov

| john.doe@epa.gov
1(337) 777-7777|

Wrong organization information? Back to Search Results. Use advanced search or request that we add vour organization.

Submit Request for Access

Once you've selected your organization, you will be required to enter an email address and phone
number where you can be contacted. Click "Submit Request for Access" (Figure 3-7). This will generate
an email that will be delivered to the email address you provided and forward you to the confirmation
screen. This email will contain a code you will need to enter to complete your registration. Make sure
to check all your email folders to ensure it was not lost in a spam folder.

Locate the email that was automatically sent to your address and enter the provided code. Once you
have located the email and code, enter the code in the "Code" box. Then, click "Create Account" (Figure
3-8).

You will then be redirected to the 'Identity Verification' screen where you will provide your personal
information to gain access to CDX. You MUST provide accurate personal information during CDX
registration in order to pass LexisNexis Electronic Identity Verification (Figure 3-9).

8


-------
Figure 3-8. Confirmation Code Entry

SEPA

tfi-i n United States Environmental Protection Agency
Home About Recent Announcements Terms and Conditions FAQ Help Virtual Assistant

CDX- Confirmation

S Contact Us

1. Program Service V ^



3. User and Organization ~ ^



A few more steps...

You will soon receive an email confirmation message at Your email address	with a validation code. Enter the

validation code below or follow the link provided in the email to activate your user account.

Resend validation code

User ID:
Code:

JDOE.REGISTRATION2

Create Account ¦ Return to CDX Home

Figure 3-9. CDX Lexis Nexis Identity Verification

vvEPA

k/i-i n United States Environmental Protection Agency
Home About Recent Announcements Terms and Conditions FAQ Help Virtual Assistant

CDX: CDX Registration: LexisNexis

S Contact Us

Logged in as JDOE.REGISTRATION2 (Loo out)

1. Identity Verification y 2. ES

9

The program you are registering for requires additional proof of identity. Identity verification allows the EPA to confirm applicants
have provided sufficient identity information in order to conduct business safely and securely. Your options are to use the
electronic identity proofing service for immediate access to your program service or to print and submit a signed form through U.S.
Postal Mail to the U.S. Environmental Protection Agency. Note: Additional LexisNexis(K) Information

LexisNexis® Instant ID
Legal Name

John

doe

Home Address

Address Line 1*

Address Line 2

City*

State*

Zip Code*

9


-------
If you do not pass LexisNexis verification you will be prompted to view, print, and sign a paper ESA. If
this happens simply view and sign the paper ESA by clicking the 'Paper Verification' link and then closing
the resulting window. This will bring you to the "MyCDX" screen. Reach out to the CDX help desk for
further instructions.

When you are done filling out your personal information, scroll to the bottom of the Identity Verification
screen. Then, check the box as shown below and click the 'Proceed to Verification' button (Figure 3-10).

Figure 3-10. CDX Lexis Nexis Identity Verification

Home Address

538 Cajundome Blvd

Address Line 2

(Lafayette	Louisiana v 70S06

Home or Personal Phone

|(337) 777-7777

Date of Birth

Month* v Day* v Year*

Last 4 of SSN

Show SSN

] The name above is me. Please proceed with LexisNexis® Validation.

Proceed with Verification

Paper Verification Exit

EPA Home Privacy and Security Notice Aoces^bUity

COX Help Desfc 88B-8QO- 19Q5 | (970) 404 S5O0 for International (alien.

About COX | Frequently Asked Questions | Terms and Conditions | Contact Us

Once you have passed identity verification, you will be directed to choose and answer 5 challenge
questions. These will be used when signing and submitting reports in CAER. After entering your answers,
click the 'Save Answers' button (Figure 3-11).

You will then be prompted to electronically sign an ESA. Click the 'Sign Electronically' button as seen
below. Click 'Accept' in the pop-up window that appears after clicking the button (Figure 3-12).
Remember that you may be able to use the same Electronic Signature Agreement (ESA) in CDX that you
use for other programs and/or systems in CDX. You may need additional ESAs for additional
organizations you are associated with. You should reach out to the help desk if you have questions
about this.

10


-------
Figure 3-11. Verification Questions

CDX Registration: Additional Verification

1. Identity Verification V / 2. Electronic Signature Agreement

You are registered for a program that requires eSignature PIN Verification. Please select five (5) challenge questions and answers.
The questions that you select should be questions that you can remember, but difficult for anyone else to guess.

Select 5 Challenge Questions and Answers

What is your favorite TV show?

T show

What is your favorite vacation destination?

T destination

Where did you first meet your spouse?

T spouse

What is your favorite book?

T book

What is your favorite pet's name?

	 T]|name

Save Answers

Figure 3-12. CDX Electronic Signature Agreement

Electronic CDX Electronic Signature Agreement

The CDX electronic signature agreement (ESA) is an agreement between yourself and CDX that will authorize your electronic signature. By signing the E5A you agree to
adhere to the conditions listed on the agreement below. Once the ESA has been signed, you will be authorized to sign and/or encrypt information for your data flow. For
questions regarding the CDX ESA, please contact the CDX Help Desk.

Signing an electronic document on behalf of another person is subject to criminal, civil, administrative, or other lawful action.

penalties for submitting false information, including the possibility of fine and imprisonment.

(13)	Agree to protect the electronic signature credential, consisting of my Central Data Exchange (CDX) user identification and
password, from use by anyone except me. Specifically, I agree to maintain the secrecy of the password; I will not divulge or delegate my
user name and password to any other individual; I will not store my password in an unprotected location; and I will not allow my
password to be written into computer scripts to achieve automated login.

(14)	Agree to immediately contact the U.S. EPA CDX Help Desk after suspecting misuse of my account. I will contact the CDX Help
Desk at 1-S88-S90-1995 as soon as possible, but no later than 24 hours, after suspecting or determining that my user name and password
have become lost, stolen, compromise or used inconsistent with CDX Terms and Conditions at https://cdx.epa.gov/terms

Name of electronic signature holder:	Mr Joshua Martin

Signature:

Date:

PLEASE MAIL THIS DOCUMENT AS SOON AS POSSIBLE TO:

U.S. Environmental Protection Aeencv



jj

Cancel

CDX Help Desk: 888-890-1995 | (970) 494-5500 for International callers



ii


-------
Figure 3-13. eSignature Screen

eSignature Widget

X

1. Authentication



Log into CDX



User:



JOSMARTIPREREGISTER



Password:

I i



i i

Show Password U



Login





Figure 3-14. MyCDX Page

oEPA

k/UI fl United States Environmental Protection Agency
Home About Recent Announcements Terms and Conditions FAQ Help Virtual Assistant

coy- Central Data Exchange

S Contact Us

Logged in as jsmithsHRINGHN (Log out)

MyCDX

Inbox

My Profile Submission History Payment History E-Enterprise Portal

Services eg Manage I

CDX Service Availability

Status ^ Program Service Name ^ Role ^

See the status for all program services

& CAER: Combined Air Emissions Reporting [ NEI Certifier ]





News and Updates

No news/updates.

Add Program Service H Manage Your Program Services

EPA Home Privacy and Security Notice Accessibility

CDX Help Desk: 888 89^1995 | (970) 494-5500 for International callers
About CDX | Frequently Asked Questions | Terms and Conditions | Contact Us

Enter all required information in the 'eSignature Widget' pop-up (Figure 3-13). After the 3 steps, click
the 'Sign' button to complete the process.

Once you have clicked to sign the ESA, you should receive an email that the process is complete. You wil
also be redirected to the "MyCDX" screen (Figure 3-14) inside your CDX account. When this happens,
your account should be activated automatically. If you are a certifier, then the 'NEl Certifier' link in the

12


-------
'Role' column on the "MyCDX" screen will be active and clickable. If you are a preparer, then "Preparer"
will appear under your Role.

Whenever you want to access CAERS, you'll go to CDX and login to enter your credentials. For security
reasons, CDX forces users to change their password every 90 days, so make sure you have your most
recent password available to you. Once you've entered your login and password, you will be taken to
your "My CDX" page.

3.3 Gain Access to CAERS and your Facility

Once you click on your role, you will be re-directed to enter CAERS, and you will see "My
Facilities" (Figure 3-15). Click on the "Request Access to a New Facility" button to request that your SLT
verify that you are associated with the correct facility.

The next screen will allow you to search for your facility by entering your SLT agency and Agency Facility
ID. If you do not know your facility ID, you may enter more search criteria (such as part of the facility
name) to find your facility. Once you've entered it, click "Search" to find your facility (Figure 3-16).

A list of facilities matching your search criteria will appear. Be sure to only select the facility you are
reporting and/or certifying for. Once you have selected it, click "Request Access" (Figure 3-17). You will
be asked to confirm you have selected the correct facility. Click "Confirm" or click "Cancel" to go back to
the previous screen. You will receive an email from your SLT confirming or rejecting your request for
access to the facility you selected. When your request has been accepted, upon reentry to CAERS, you
should see your facility, listed in your "My Facilities" page (Figure 3-18).

Figure 3-15. "My Facilities" Page in CAERS

13


-------
Figure 3-16. Facility Search in CAERS

Mv Facilities > Facility Search

A CBI Disclaimer CAERS Help Contact CDX

Request Access to Facility

Agency:
City:

Georgia Department of Natu

Name:
State:

Agency Facility ID:

EPA Home | MyCDX | Accessibility Notice | Privacy and Security Notice

Figure 3-17. Request Access to Selected Facility

Request Access to Facility

Agency:

District Department of the Er v Name:

Facility

Agency Facility ID:

999999



City:

State:

v Postal Code:















1

n

;t | Back to My Facilities

Filter Table: Se.

Filter Request Status:









Facility Name

Agency Facility ID

Address







My Facility Inc.

999999

123 MyFacility Road, Washington, DC 99999







EPA Home | MyCDX | Accessibility Notice | Privacy and Security Notice

14


-------
Figure 3-18. "My Facilities" Page Listing Facilities

3.4 Opt in-Process for Facilities Reporting to GADNR

This section applies only to all Georgia Department of Natural Resources (GADNR) facility
preparers and certifiers. If you do not report to GADNR, you may proceed to Section 4.

After logging in and having received access to your facility from GADNR, you will be redirected to the
Emissions Reports page. Now, you will begin your opt-in/opt-out process. Click on "Create New
Report", you will be generating a report no matter whether you opt in or opt out, but the process for
each will be different. See Figure 3-19.

15


-------
Figure 3-19. Starting the GADNR Opt-in/Opt-out Process

Via a pop-up window (Figure 3-20), the system will ask about the status of your facility. Only select
"Permanently" or "Temporarily" Shutdown if the facility had no activity in the inventory year you are
reporting. For annual reports, "shutdown", either temporarily or permanently means that the facility
did not operate from January 1st to Dec. 31st of the inventory year. If the facility operated at all, even one
day, in that inventory year, then the facility is considered to have been operating for that inventory year.
If you have further questions, please reach out to your SLT before you make a selection to avoid having
to go through the process again. Otherwise, your facility was "Operating".

3.4.1 If the Facility was Operating

Your selection will take you to another pop-up window asking if the facility met the Potential to
Emit (PTE) thresholds listed for the inventory year you are reporting (Figure 3-21).

16


-------
Figure 3-20. Selecting Operating Status for GADNR Facilities

Agency ID: 99999999
Facility Inc.

123 Main street
MytomGA 12345
Agency. GADNR

Emission Reporting Opt-In

X

You are about to report facility emissions data for the 2021 Reporting Year.



Was this facility operating in 2021?



O Yes, Operating



O No, Temporarily Shutdown



O No, Permanently Shutdown





O C3

Greate New Report

Figure 3-21. Potential to Emit Threshold Questionnaire for GADNR Facilities

Mv Facilities > Emissions Reports

Agency ID: 99999999

123 Main Street
r«tytown, GA12345
A8encyt GADNR

Emission Reporting Opt-In

You are about to report facility emissions data for the 2021 Reporting Year.

Was this facility operating in 2021?

® Yes, Operating
O No, Temporarily Shutdown
O No. Permanently Shutdown

Facility Emissions Thresholds

Note that the thresholds below pertain to potential emissions, except for lead. The threshold for lead (Pb) is based on actual emissions.
Pollutant	Threshold (tpy)

VOC
SOx
NOx
CO

PM10-PRI
PM25-PRI
NH3

250
2500
2500
2500
250
250
250

Is the facility below ALL of the thresholds listed?

O Yes
O No

3.4.1.1 Facilities Bellow All Pollutant Thresholds

If you answered "Yes" to the question "Is the facility below ALL of the thresholds listed?" (Figure
3-21), then your facility will be opting out of emissions inventory reporting for the inventory year. The
next screen you see, will show you the Summary Screen in CAERS where the summary will appear
empty. Your previous year data will not be used to prepopulate the current inventory year, as your

17


-------
facility will not be submitting an annual report, but instead, will be saved for the next time your facility
reports. Your report for this inventory year is effectively reporting that the facility opted out from the
requirement to submit an emissions inventory report for this inventory year (Figure 3-22).

Please review your facility information carefully. Even if you are going to opt out, you will need to have
updated facility information so that it is current, including a point of contact, for any subsequent
submissions. If any information is incorrect or missing, please edit it. Click on "Run Quality Checks" to
see if you have any errors or omissions in facility data that need to be corrected. If there are corrections
that you cannot make, as your SLT may not authorize you to do so, please reach out to them as soon as
possible before you certify and submit. Otherwise, you may have to go through this process again until
the correction is provided.

If you are opting out, you will be required to attach your Potential to Emit Threshold Analysis (TA) excel
file. You can click on "Attach Report Document" to do so (Figure 3-23). Please note that GADNR
requires a specific template to be used for the opt-out TA. The TA template for GADNR reporters can be
found in the GECO website in the Emission Inventory Application section. Reach out to GADNR staff if
you need further guidance on this. Make sure that the facility data in your TA template matches that
listed in CAERS exactly to avoid having rework later. Failure to attach the TA will result in an error that
will not allow the certifier to proceed with certification (Figure 3-24). Once the TA is attached the
certifier will click "Certify and Submit to SLT". GADNR will only reject this submission and return to the
facility if it encountered errors in the analysis. If so, the process must be re-started by going back to the
"Emissions Reports" page and clicking "Delete". Once that is done, the system will re-set and you will
start the Opt in/Opt out process again.

Figure 3-22. Report Summary Page for a Facility that Opted Out

18


-------
Figure 3-23. Attaching the Thresholds Analysis for GADNR Facilities that Opted Out

> 2021 Emissions Report

:y ID: 99999999

2021 Emissions Report

Pollutant

Total Emissions (To

Attach Report Document

x

Search for document file to be attached to the 2021 Emissions Report for Facility Inc..



Comments:



(2000 character limit)

1 Attachment: Click to browse-

Browse 1

1

i

Date	User ID



ear Reported Emissions Previous Submittal Year

t Summary I Download Process Emissions Summary

Attach Report Document

iust attach your Potential to Emit (PTES

Figure 3-24. Certify and Submit for GADNR Facilities that Opted Out

Agency ID: 99999999
Facility Inc.

123 Main Street
Mytown, GA12345

Agency: GADNR

Report Summary

Report Facility & Emissions Information

Perform Quality Checks

Submit to SLT Authority

Approved by SLT Authority

Report Summary

Pollutant

Type Fugitive Amount Stack Amount Units of Measure 2021 Reported Emissions

Previous Year Reported Emissions

Previous Submittal Year

Total Emissions (Tons)

_ _ - 0

0

-











1

Download Report Summary 1 Download?

Tocess Emissions Summary



Preparer/NEI Certifier Attachments





Date

User ID

User Name

Comments

Attachments

3/25/22

NEI Certifier-JULIAGAMAS

Julia Gamas



Threshold Analysis My Facility 99999999.xlsx ffi

Attach Report Document

Certify and Submit to SLT

EPA Home | MyCDX | Accessibility Notice | Privacy and Security Notice

3.4.1.2 Facilities Above at Least One Pollutant Threshold

If you answer "No" to the question "Is the facility below ALL of the thresholds listed?" (Figure
3-21), then your facility will be opting in. The next screen you will see will be the "Report Summary"
screen. If you have submitted a previous year report, your data from that report will have prepopulated
this screen and you can begin your report per section 4.1.3 of this User Guide. Note that if the facility

19


-------
PTE emissions exceeds some of the pollutants, the actual emissions of all pollutants emitted at the
facility must be reported.

3.4.2 If the Facility was Temporarily or Permanently Shut Down

After selecting either "Temporarily Shutdown" or "Permanently Shutdown" you will be re-directed
to the facility summary page, but the previous year report will not pre-populate your current year
report. The Report Summary screen for facilities that have shut down will be the same as for the opted
out facility (see Figure 3-22). Your report for this inventory year, is effectively reporting the status
change for your facility, and the status year will automatically be marked as the previous year (inventory
year). See section 4.2.1 for more details on facility operating status. You will not be required to submit a
threshold (TA) analysis if your facility was shut down.

4 Reporting Emissions and Facility Information via the User Interface
4.1 Navigating the User Interface

4.1.1 General Description of User Interface Features

This section will help you understand the basics about navigating the CAERS User Interface (Ul), that
will be helpful whether you choose to do your reporting via Ul, bulk entry, or bulk upload. The Ul has
many pages and data entry points, however, there are some common themes throughout the Ul. This
list will help you understand the general layout of the Ul and its characteristics. Specific features are
explained in more detail, including screenshots, in subsequent sections and are not duplicated here to
avoid repetition.

General features (refer to Section 4.1.3, Figure 4-3):

•	Breadcrumbs at the top of the screens displaying the path that got you to the current screen
from previous screens.

•	Submission steps bar at the top of the screen that indicates what step you are on in the
submission process.

•	A menu with links to different facility and emissions data pages on the left-hand side of the
screen, that will help you find the relevant screens for viewing and data entry. Where multiple
units exist, the menu can be expanded and collapsed.

•	Link to "MyCDX" at the bottom of the screen.

•	Link to "Help" at the top right of your screen that takes you to a page containing the help desk
contact information and additional resources.

User interface data entry features:

•	Organization of data in each screen in boxes. For example, facility information is organized in
the following boxes: Facility Information, Facility North American Industrial Classification
System (NAICS) Codes, Contact Information (Section 4.2.1, Figure 4-5. Facility Information
Page).

•	Greyed out data entry boxes indicating where data is not expected to be changed by the user
(Section 4.2.1, Figure 4-6, for example).

•	Asterisk symbols indicate required data fields. Error messages for missing data fields and for
data fields that are conditionally required. (E.g. entering one data field may require entry of a
companion data field)

20


-------
•	Question mark icons next to data fields to explain what they are and how to use them. In
addition, the glossary in the help section contains all these definitions and can be downloaded
for your reference.

•	Drop down menus for data entry boxes to assist the user in entering the relevant data without
errors (Section 4.2.1, Figure 4-6 for example).

•	Pop-up windows directing the user to make a choice or enter specific information related to the
page the user is in (Section 4.2.1, Figure 4-7, for example).

•	Data entry quality checks (warnings in purple, critical errors in red) to help the user to address
issues and corrections before submission (Section 4.2.2, Figure 4-11, for example)

•	"Trash can" icons to delete specific sub-facility components. These are not to be used when that
component existed in a previous submission. If data was entered in error during the current
submission, the trash can should be used. If the data existed in a previous submission, then the
component operating status should be changed to temporarily or permanently shut down (as
the case may be), and the year of that change should be recorded as well (Section 4.2.1, Figure
4-6 for example).

•	Links for sub-facility components on lists to indicate when the user can edit them from there
(Section 4.2.2, Figure 4-10, for example).

•	Process of adding sub-facility components. These must be added first before they can be
associated with other components. When a component is added as new, the associations won't
show up on the screen for that component until the component information has been filled out
and saved (for example, compare screens for Figure 4-11 and Figure 4-13 in Section 4.2.2).

Then, the component page can be re-opened and boxes for the associations will appear.

4.1.2 Emissions Reports Page

From "My Facilities", click on Begin/Continue Reporting. This will take you to the "Emissions
Reports" page, where you can see all the reports for that facility (See Figure 4-1 for a new report, and
Figure 4-2 for a report in progress). The CAER system will contain your report from the last year you
submitted one, which will serve as a starting point for you to begin a new report for the current
inventory year you are reporting. Note: For facilities reporting to GADNR, make sure to see section 3.4
for Georgia's op-in/opt-out process before you proceed with this section.

From this screen you have options to work on your report as follows:

•	If you will be reporting via the Ul or Bulk Entry:

o To start your current report click on "Create New Report" (Figure 4-1) to start reporting.
This will prepopulate your current year report with your previous year data. You will be
re-directed to the facility "Report Summary" page. If your facility has control
equipment, you should also familiarize yourself with Appendix A before beginning a
report.

o To continue your current report if you have already started it in a previous session, click
"Continue" to be redirected to the Ul (Figure 4-2).

•	If you will be reporting using Bulk Upload:

o You can download your previous year data in the pre-formatted template. This can be
used as a starting point to edit and enter your current year report. If you are using bulk
upload to enter your report, refer to Section 5 and, if your facility has control
equipment, refer to Appendix A before beginning a report.

o Once you've filled out your template with your current report, you can upload it from
this screen as well by clicking on "Upload Report".

21


-------
•	If you would like to view a previous year report, you can click on "View" to enter the Ul and see
the report without modifying it.

•	If you find that your current year report is in error and would like to start over, you can click on
the "Delete" button. Note that if you delete a previous year report, you will not be able to get
that data back easily and recovery may take several weeks. If you have any doubts, download a
copy of your current report in the bulk upload template before you click "Delete" to ensure you
can save this information.

Note that, at this time, you will not be able to re-submit a previous year report for a previous reporting
year.

Figure 4-1. Begin Emissions Report

22


-------
Figure 4-2. Emissions Report Page

4.1.3 Report Summary Page

Once you have selected a facility and report from the "My Facilities" page, you will be taken to a
"Report Summary" page (Figure 4-3). Your new report will be preloaded based on your previous year
submission, and include a list of pollutants for that facility, the reported emissions in the current report,
and the tons for each pollutant that were reported in your facility's previous submission.

23


-------
Figure 4-3. Facility Report Summary Page

Mv Facilities > Emissions Reports > 2022 Emissions Report

Agency ID: 999999
My Facility Inc.
123 MyFacility Road
Washington, DC 99999
2022 Emissions Report
Agency: DOEE

Report Summary <
Report History
Quality Checks
Report Creation Log
Monthly Fuel Reporting
Data Bulk Entry
~Facility Inventory

Facility I nformation
Emissions Units

~Emissions Inventory

~	B201

~	B202

Report Facility & Emissions Information

Perform Quality Checks

Submit to SLT Authority

ACBI Disclaimer CAERS Help Contact CDX

Approved by SLT Authority

Report Summary

Pollutant

Type

Fugitive Amount

Stack Amount

Units of Measure 2022 Reported Emissions

Previous Year Reported Emissions

Previous Submittal Year

Carbon Monoxide

CAP

0.45

84.55

Tons

85

85

2021

Nitrous Oxide

GHG

0

195

Tons

19.5

19.5

2021

PM2.5 Filterable

CAP

0.00054

0.01746

Tons

0.018

0.018

2021

PM2.5 Primary (Filt + Cond)

CAP

0.00075

0.02425

Tons

0.025

0.025

2021

Volatile Organic Compounds

CAP

0

13

Tons

13

13

2021

Total Emissions (Tons)









117.543

117.543



Download Report Summary I Download Process Emissions Summary

Preparer/NEI Certifier Attachments

Attach Report Document

You will see breadcrumbs in the dark blue bar at the top of the screen. These display the path that got
you to the current screen from the "My Facilities" page. By clicking on any of the links, you will be
returned to a previous page. For example, from "2020 Emissions Report" you can click on "Emissions
Reports" to be taken back to that page.

Below the breadcrumbs, at the top center of the screen, you'll see a bar showing the four main steps of
submission that will help guide you through the submission process:

•	Report Facility & Emissions Information,

•	Perform Quality Checks,

•	Submit to SLT (your State, Local, or Tribal) Authority, and

•	Approved by SLT Authority.

On the left-hand side you will see an expandable menu with links that will take you to different pages:

•	Report History (shows a list of actions associated with the report over time and who performed
them, for example, when it was created, submitted, whether the SLT has approved it).

•	Quality Assurance (QA) Checks (takes you to the list of QA checks that your report, as it stands,
is currently generating) see Section 7.

•	Data Bulk Entry (takes you to the bulk entry tabs).

•	Facility Inventory data (with summary pages at different levels of detail: facility information,
emissions units, release points, control devices, control paths) see Section 4.2.1.

•	Emissions Inventory (a collapsible list of units that you can expand to view the processes
associated with each unit) see Section 4.3.

24


-------
4.1.4 Including an Attachment in Your Report

You can add a file to your report to explain your calculations where CAERS has not done the
calculations for you (e.g. when your estimation method is mass balance, engineering judgement, or the
emission factor you are using is not listed in the CAERS menu). To attach a file to your report, go to the
"Report Summary" page from the left-hand side menu. Below the "Report Summary" section you will
see a section titled "Preparer/NEI Certifier Attachments". Click on the "Attach Report Document" on the
bottom right of that section (see Figure 4-4). A window will pop up where you will be able to enter
comments if needed, and then select the file to attach by using the "Browse" button to find and retrieve
your attachment. Click "OK" when you have selected the right file to attach. Your SLT may require that
the attachment should show the formulas and their application in an excel file. For your SLT, a verbal
description may not be sufficient, as your SLT should be able to verify your estimates. Please be advised
that if you do not submit your attachment in the format your SLT requires, this may result in your report
being rejected and sent back to you automatically.

Figure 4-4. Including an Attachment

Washington. DC 99999
2022 Emissions Report
Agency; DOEE

Report History
Quality Checks
Report Creation Log
Monthly Fuel Reporting
Data Bulk Entry
~Facility Inventory

~Emissions Inventory

~	B201

~	B202

Attach Report Document

Search for document file to be attached to the 2022 Emissions Report for My Facility Inc..
Comments:

Pollutant

Carbon Monoxide
Nitrous Oxide
PM2.5 Filterable
PM2.5 Primary (Filt
Volatile Orgs
Total Emissions (To

Attachment:

(2000 character limit)
Click to browse...

ir Reported Emissions

Previous Submittal Year

2021
2021
2021
2021
2021

Preparer/NEI Certifier Attachments

Download Report Summary I Download Process

Attachments

Attach Report Document

EPA Home | MyCDX | Accessibility Notice | Privacy and Security Notice

Once you have attached the file you will see it listed in the attachments section. It will also appear listed
in the "Report History" page that you can get to from the left-hand side menu of your screen.

If you need to remove an attachment, from within the "Report Summary" page, click on the garbage
icon to the right of the document attachment name. You will be asked to confirm the deletion. Once
deleted, the attachment will no longer appear in the list of attachments. However, a record of the
attachment upload and its removal will appear in the "Report History" page to help you keep track of
your work and ensure you have the most updated attachment you wish to submit with your report.

25


-------
4.2 Facility Inventory

4.2.1 Facility Information

From the left-hand side menu, click on "Facility Inventory" to expand that menu. Click on
"Facility Information" to get to the facility information screen (Figure 4-5).

Figure 4-5. Facility Information Page

Washington, DC 99999
2022 Emissions Report
Agency: DOEE









Facility Information



Report Summary

Agency Facility ID:

999999 Latitude: 38.870926 Operating Status:

Operating

Report History

Facility Name:

My Facilitylnc Longitude: -77.035803 Operating Status Year:

2012

Quality Checks

Facility Category Code:

CAP Major



Report Creation Log

Facility Address:

123 MyFacility Road Mailing Address: 123 MyFacility Road





Washington, DC 99999 Washington, DC 99999



Monthly Fuel Reporting

County:

District of Columbia



Data Bulk Entry

BIA Code:





~Facility Inventory

Description:
Comments:





Facility Information <







Emissions Units







Release Points



Facility NAICS Codes



Control Devices







Control Paths







~Emissions Inventory

NAICS Description

NAICS Code NAICS Code Type



» B201

Dog and Cat Food Manufacturing 311111 PRIMARY

Bf I

~ B202





+













Facility Contact Information

Q i



Contact Type:

Emissions Inventory Phone Number: 999-999-9999 Ext:





Contact Name:

John Johnson Email Address: john.johnson@MyFacility.com





Contact Address:

123 MyFacility Road Mailing Address: 123 MyFacility Road County:
Washington, DC 99999 Washington, DC 99999

District of Columbia















Add Facility Contact Information









EPA Home | MyCDX | Accessibility Notice | Privacy and Security Notice

You will be able to edit facility information by clicking on the "Edit" button at the far right, which will
take you to the facility information edit page (Figure 4-6). Note that fields that have been locked will
not be editable. They will appear in gray. You should contact your SLT authority (for example, GA DNR)
if you think there is an error in locked fields. A gray arrow within a data field box indicates a drop-down
menu is available to choose your entry.

• Facility Operating Status: If the facility operated partially in the reporting year and was
permanently shut down in the reporting year, you will need to leave the "Operating" status
unchanged for the year you are reporting, and change it the following reporting year. For
example, if the facility operated in part in 2019 and shut down for the rest of 2019, you would
change its status to permanently shut down in your 2020 inventory year report, but would have
it as operating in 2019.Once you change the operating status to "Permanently Shut-down", all
units, processes, controls and release points will also be automatically set to "Permanently
Shutdown", and you will no longer be able to enter data for the facility. The operating status
year can be set to a year in the past, but not if emissions were reported in that year in a
previous year report. An operating facility that reported 0 emissions in a previous year, will still
be considered "Operating", so you should ensure consistency in your reports overtime.

26


-------
Figure 4-6. Editing Facility Information

Agency ID: 99999999
Facility Inc.

123 Main Street
Mytown, GA12345
2020 Emissions Report
Agency. GADNR

Report Summary
Report History
Quality Checks
Data Bulk Entry
~Facility Inventory

Facility Information <
Emissions Units
Release Points
Control Devices
Control Paths

~Emissions Inventory

Report Facility & Emissions Information

Perform Quality Checks

Submit to SLT Authority

Approved by SLT Authority

Q Agency Facility ID:
0 Facility Name:

0 Longitude:

0

Facility Category
Code:

0 Facility Address:
City:

ZIP code:
0 BIACode:

99999999
Facility Inc.

123 Main Street

Mytown

12345

Facility Information

0 Operating Status:*

Operating

Operating but State/Local/Tribe Not Reporting Emissions
Operating but State/Local/Tribe Reporting Emissions in the Nonpoint Category
Permanently Shutdown
Temporarily Shutdown

State:
County:

GA
Bacon

Mailing Street
Address:

City:

Description:
Comments:

123 OAR Road

Atlanta

• Adding NAICS Codes: Under the "Facility Information" box, you will be able to add a NAICS code
if your SLT allows it. More than one NAICS are allowed as secondary and tertiary NAICS codes,
but a single NAICS should be designated as the primary NAICS code. When you click the "+"
button at the bottom right of that box, a pop-up window will appear to help you search for your
NAICS (Figure 4-7). Type the digits of your NAICS and a menu for the NAICS that contain those
numbers will appear to help you select the correct code (Error! Reference source not found.). O
nee you've selected your NAICS, click the "Submit" button, if you have questions about NAICS
you can reference the U.S. Census Bureau. NAICS change every 5 years. At the time this
document was written, the codes being referenced were from 2017.

27


-------
Figure 4-7. Edit Facility NAICS codes

Figure 4-8. Find and Select NAICS Code



Combined Air Emission's Reporting Form

Select an NAICS Code to add to the facility

;y&

Select NAICS Code:

334

Approved bi

itylD:
e;

111334 • Berry (except Strawberry) Farming

333411	- Air Purification Equipment Manufacturing

333412	• Industrial and Commercial Fan and Blower Manufacturing

333413	- Industrial and Commercial Fan and Blower and Air Purification Equipment Manufacturing

333414	¦ Heating Equipment {except Warm Air Furnaces) Manufacturing

333415	- Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing

334111 - Electronic Computer Manufacturing

334112	- Computer Storage Device Manufacturing

334113	- Computer Terminal Manufacturing

334118	- Computer Terminal and Other Computer Peripheral Equipment Manufacturing

334119	• Other Computer Peripheral Equipment Manufacturing
334210 - Telephone Apparatus Manufacturing

334220 • Radio and Television Broadcasting and Wireless Communications Equipment Manufacturing
334290 - Other Communications Equipment Manufacturing
334310 - Audio and Video Equipment Manufacturing

334411	- Electron Tube Manufacturing

334412	- Bare Printed Circuit Board Manufacturing

334413	- Semiconductor and Related Device Manufacturing

334414	- Electronic Capacitor Manufacturing

334415	¦ Electronic Resistor Manufacturing

2017
Rockdc

Emissions Inventory

Phone Number:
Email Address:

• Facility Contact Information: Below the NAICS code box, you should find the "Facility Contact
Information" box(es). Note that if you have not submitted information to CAERS before, no

28


-------
boxes will be displayed yet. You can enter as many contacts for the facility as you need. For
example, you may enter a point of contact as the facility expert on emissions inventory criteria
pollutant questions, and another for the Toxics Release Inventory expert. Click on the "Add
Facility Contact Information" at the bottom right of the screen to open a window to enter new
facility contact information (Figure 4-9). Enter all relevant information such as name, number,
and make sure to select a "Contact Type".

You will be required to enter at least one contact for National Emissions Inventory (NEI)
reporting. This should be the person that your SLT authority can reach out to if they have
questions about the submission. If a contact person for the NEI is missing, a QA error will
appear at the top of the "Facility Information" page. For the NEI contact select contact type:
"Emissions Inventory". Click "Save" after adding the information. The application will
automatically take you back to the "Facility Information" page and you should be able to see
your contact information displayed at the bottom of the page. You can also edit an existing
contact by clicking on the "Edit" button for that contact. This will take you to that contact's edit
page where you will be able to make changes.

Figure 4-9. Enter Facility Contact Information

Data Bulk Entry
~Facility Inventory

Facility Information
Emissions Units
Release Points
Control Devices
Control Paths

~Emissions Inventory

Facility Address:

BIA Code:

Description:

Comments:

123 Main Street
Mytown, GA12345

Mailing Address:

123 OAR Road
Atlanta. GA 78912

County:

This facility isfor EPA testing purposes only.

Phone Number:

Email Address:

Contact Information

Contact Type:*
Last Name:'
Ext.:

Emissions Inventory

Asbestos

Billing/Invoice

Compliance

Emissions Inventory

Contact Street
Address: *

City:*

County:

~ Make mailing address the same as contact address

Mailing Street
Address:

City:

ZIP code:

Environmental
Facility
Monitoring
NSR Billing
NSR Permitting
On Site Operator
Permit

Responsible Official

Technical

Title V Permission

4.2.2 Emission Units Page

From the left-hand side menu, click on "Emissions Units" to go to a list of units in your facility
(Figure 4-10).

29


-------
• To add a unit, click on the plus sign at the bottom of the list. This will take you to a blank unit
page (Figure 4-11). Add all the data fields. Messages will appear where required information is
missing. When you have entered all unit information, click "Save" and this will take you back to
the Units page. After you have finished with your entries or edits, click "Save" to go back to the
"Emissions Units" page. Your new unit will now be listed on that page as an existing unit. If you
are entering new unit data and find you have begun entering it in error, click "Cancel" to take
you back to the "Emissions Units" page without saving any edits. You should consult with your
SLT on what should be used to determine a "Unit ID," such as what is listed in a permit, etc.
before assigning an ID to a new unit.

Figure 4-10. Emissions Units Page

Agency ID: 999999
My Facility Inc.
123 MyFarility Road
Washington. DC 99999
2022 Emissions Report
Agency: DOEE

Report Facility & Emissions Information

A

Perform Quality Checks

Submit to SLT Authority

Approved by SLT Authority











Emissions Units





Report Summary

Unit ID Unit Type

Unit Description

Operating Status



Report History

B201 Boiler

Boiler Building A

Operating

i

Quality Checks

B202 Boiler

Boiler Building B

Operating

OD

Report Creation Log







+

Monthly Fuel Reporting
Data Bulk Entry
~Facility Inventory

Facility Information
Emissions Units <

Release Points
Control Devices









~Emissions Inventory

t 6201
~ 8202









EPA Home | MyCDX | Accessibility Notice | Privacy and Security Notice

Figure 4-11. Adding a New Unit

Mv Facilities > Emissions Reports

> 2022 Emissions Report





A CBI Disclaimer CAERSHelp Contact CDX

Agency ID: 999999
My Fadlity Inc.

Report Facility & Emissions Information

Perform Quality Checks

Submit to SLT Authority

Approved by SLT Authority

123 MyFacility Road
Washington. DC 99999
2022 Emissions Report
Agency: DOEE











Emission Unit Information













Report Summary

© Unit ID:*

A401 © Operating Status:'

-

Report History

© Unit Type Code:*

v I © Operating Status Year: *

Quality Checks

© Unit Description:
© Unit Design Capacity:







Report Creation Log

Aerated Grit Chamber
Aeration Basin

Agricultural Fiber Board Press
Air Gas Furnace
Anaerobic Digester
Atmospheric Refiner
Batch Digester
Belt Filter Press

lit Design Capacity UoM:

-

Monthly Fuel Reporting
Data Bulk Entry
~Facility Inventory
Fadlity Information
Emissions Units
Release Points
Control Devices
Control Paths
~Emissions Inventory

> B201
>6202

Comments:





Black Liquor Oxidation System
Black Liquor Storage
Bleach Storage

Bleaching and Extraction Tower

Blend Chest

Boiler

Bottoms Receiver Vessel
Brown Stock Refiner
Calciner

Chemical Reactor

Chemical Recovery Combustion Unit ~



mm











EPA Home | MyCDX | Accessibility Notice | Privacy and Security Notice

30


-------
• To edit an existing unit, from the "Emissions Units" page click on the corresponding unit ID from
the list of units to be taken to that unit's page (Figure 4-12). On the unit page, you'll see the
"Emission Unit Information" box. Click on the "Edit" button at the top right of the screen to
make changes to the emissions unit information. This will take you to that unit's edit screen
(Figure 4-13). When you are finished with your edits click "Save" to take you back to the
"Emissions Units" page. If you entered data by mistake, click "Cancel", the changes will not be
saved, and you will be returned to the "Emissions Units" page.

Figure 4-12. Example of a Page for a Specific Unit

2019 Emissions Report
Agency: GA

Report Summary
Report History
Quality Checks
•Facility Inventory
Facility Information
Emissions Units
Release Points
Control Devices
Control Paths
"Emissions Inventory

~	FSA

~	FIB

~	PIOl

~	VPOl <

~	VP02

» VP02A
» VP02B

~	VP02C

~	VP02D

~	VP02E

~	VP02F

~	VP04

Emission Unit Information

Unit ID:

Unit Description:

Unit Design Capacity:

Comments:

VPOl

Nebraska Package boiler
279

Back-up boiler

Unit Type Code:

Unit Status Year:
Unit Design Capacity
UoM:

Boiler
2008

E6BTU/HR

Unit Status:
UoM Description:

Operating

MILLION BTU PER
HOUR

Process ID

NOX1

Processes Associated with this Emissions Unit

see

10200601

Controls Associated with this Emissions Unit

Control	Description

7894768	Flue Gas Recirculation

Control Path

227

Figure 4-13. Editing a Unit

Agency ID: 999999
My Facility Inc.
123 MyFadlity Road
Washington. DC 99999
2022 Emissions Report
Agency: DOEE

Report Facility & Emissions Information

Perform Quality Checks

Submit to SLT Authority

Approved by SLT Authority

~Emissions Inventory

Report Summary
Report History
Quality Checks
Report Creation Log
Monthly Fuel Reporting
Data Bulk Entry
~Facility Inventory
Facility I nformation
Emissions Units
Release Points
Control Devices
Control Paths

© Unit ID:4
© Unit Type Code:'
© Unit Description:
© Unit Design Capacity:
Comments:

Emissions Unit Information

Processes Associated with this Emissions Unit

B201



© Operating Status:'

[ Operating

HI

Boiler



© Operating Status Year:

1



Operating

Boiler Building A





Permanently Shutdown
Temporarily Shutdown

200



© Unit Design Capacity UoM:

HP

-



Controls Associated with this Emissions Unit

~ B201 < Process ID

see



Control

Description

Control Path

~ 8202 P201

10300101

I

CTRLB



PTHB

• To delete a unit, you should only delete a unit using the garbage can icon if you added it to this
year's report and that addition was an error. If the unit existed in a previous year's report, and

31


-------
is no longer in use for the entirety of this reporting year, you should click on its ID and change its
status from "Operating" to "Permanently Shutdown" and mark the status year as the year when
it was shut down. If the unit operated part of the reporting year and then was permanently shut
down, then the unit is considered as operating during that reporting year, and should be marked
as permanently shutdown the next year.

•	Important additional considerations about units:

o New but inactive units: Please do not create a new unit and then mark it as temporarily
or permanently shut down. If you have a new unit that will report emissions in a future
year, add it in that future year report.

o Relabeling pitfall: Please do not relabel current units in the bulk upload template with
new ID's. The system will not recognize these units as existing, effectively adding units
to your facility instead of simply replacing the ID's. If you do, your facility inventory of
record with EPA will reflect additional units and potential emissions that do not really
exist in your facility. Your efforts in this regard will help us keep your facility inventory
up to date.

o Choosing IDs: If your SLT allows it, the reporter can choose the ID for the unit. There is
a requirement that no two units be labeled with the exact same ID. You should choose
ID's that you will not find confusing to use in future.

•	Editing processes: At the bottom of each unit's page, you will also see processes and controls
associated with that unit. You can add, edit, or delete processes associated with this unit from
this page by clicking on the process ID. See section 4.3.2 to learn how to add, edit, or delete
processes.

•	Editing controls: You can also edit controls from this page. Note that if no controls appear on
the unit's page, but there are existing controls that should be associated with this unit, you must
add those controls to the system first. They will appear on this unit page once you have done
so. See section 4.2.4 to learn how to add, edit or delete controls.

4.2.3 Release Points Page

From the left-hand side menu, click on "Release Points" under the "Facility Inventory" heading.

You will see a list of release points associated with the facility (Figure 4-14).

32


-------
Figure 4-14. Release Points Page

Agency ID:999999
My Facility Inc.

Report Facility & Emissions 1 nformation Perform Quality Checks Submit to SLT Authority

fir ft ft

Approved by SLT Authority
•

123 MyFacility Road
Washington. DC 99999
2022 Emissions Report
Agency: DOEE



Release Points









Report Summary

Release Point ID Release Point Type Release Point Description

Operating Status

Report History

RP2 Goose Neck Release Building A

Operating fin

Quality Checks

RP4 Fugitive 3-D: Center of Release Footprint Coords Release Fugitive

Operating j®

Report Creation Log



+

Monthly Fuel Reporting
Data Bulk Entry









~Facility Inventory





Facility Information





Release Points <
Control Devices
Control Paths





~Emissions Inventory





» B201
~ B202





EPA Home | MyCDX | Accessibility Notice | Privacy and Security Notice

•	To add a new release point, click on the "+" sign at the bottom right of the list. This will take
you to a blank release point page. Enter all relevant information. Messages will appear for
required fields. Dropdown menus are available for some data fields by clicking on the arrow in
the data field box (Figure 4-15). Click "Save" to take you back to the "Release Points" page.

Your new release point will now appear in the list of existing release points. If you entered new
release point data by mistake, click "Cancel" so the changes will not be saved. You will be taken
back to the "Release Points" page. Consult with your SLT on what should be used to determine
a "Release Point ID," such as what is listed in a permit, etc.

•	To edit an existing release point, click on the release point ID from the list of release points.

This will take you to that release point's information page (Figure 4-16). Click on "Edit" at the
top right of the screen for that release point. You will also be taken to the release point page
(similar to that of a new release point), where you will enter all relevant information about that
release point (Figure 4-17). A gray arrow icon next to a data field indicates a drop-down menu
that will allow you to make a choice. Consult with your SLT before attempting to edit the ID of
an existing release point in case the SLT has requirements on how those ID's should be set, and
whether they should be modified.

•	To delete a release point, note that the garbage can icon on the "Release Points" page should
only be used if you added a release point by mistake during this submission. If you are retiring a
release point that existed in a previous report, then you must go into that release point's screen
by clicking on the release point ID from the list and change the operating status to "Permanently
Shutdown".

•	Important additional considerations about release points:

o New inactive release points: Please do not create a new release point and then mark it
as temporarily or permanently shut down. If you have a new release point that will
report emissions in a future year, add it in that future year report,
o Relabeling pitfall: Please do not relabel current release points in the bulk upload

template with new ID's. The system will not recognize these release points as existing,
effectively adding release points to your facility instead of simply replacing the ID's. If
you do, your facility inventory of record with EPA will reflect additional release points

33


-------
and potential emissions that do not really exist in your facility. Your efforts in this
regard will help us keep your facility inventory up to date,
o Choosing IDs: If your SLT allows it, the reporter can choose the ID for the release point.
There is a requirement that no two release points be labeled with the exact same ID.
You should choose ID's that you will not find confusing to use in future. Consult your
SLT on any rules the SLT may have regarding IDs. For example, the SLT may want your
release point to be labelled by a specific naming convention.

Figure 4-15. Adding a New Release Point

R< !s\r,e Point infor rrwtton

Report History-
Quality Checks
Report Creation Loj

, f,-i
Data Bulk Entry
•f 1' I'ltV ¦ ¦	,

© RticSbe Pomt IP "
© RtW^ePi.' n? FViuipistm
© ReW^e Po ru Type '
© Lrttltl'dP \W'M>e

© FMU>sr. Wloctv Meruit-
© l-vit iiac f |n\v Rat^
© F\tt Gas Tfnj,pi Murp Me^ui

©Sts^k ght Mf,V
©Stuk Lengtn Mej

© Oonaiing Hatus"
0 CVrm.iRSntus Yrat
© F- w Line CVihi-cp IvV.i-
v.ce

JxtCPsVe'fX itvUoM
riov/Hatpil°M

© StuckDiaiiKt^r Mfjiwp
© S'dvk Wult'' Meci-usf

On an existing release point's page, you can view processes and controls associated with that particular
release point. See Section 4.3.2 on how to edit processes and Section 4.2.4 on how to edit controls.
Once you have done so, they will appear in the release points page.

34


-------
Figure 4-16. Example of a Page for a Release Point

Agency ID: 999999
My Facility Inc.
123 MyFarility Road
Washingtoa DC 99999
2022 Emissions Report
Agency: DOEE

Report Summary
Report History
Quality Checks
Report Creation Log
Monthly Fuel Reporting
Data Bulk Entry
¦»Facility Inventory

Release Points
Control Devices
Control Paths

^Emissions Inventory

~	B201

>	B202

Report Facility & Emissions Information

Release Point ID:

Perform Quality Checks

Submit to SIT Authority

Approved by SLT Authority

Fence Line Distance:

Fence Line Distance UoM:
Exit Gas Velocity Measure:

Exit Gas Velocity UoM:

Stack Height Measure:
Stack Height UoM:
Comments:

FEET PER MINUTE

Release Point Information

Release Point Type:
Release Point Description:
Latitude Measure:

Exit Gas Flow Rate
Measure:

Exit Gas Flow Rate UoM:

Stack Diameter Measure:
Stack Diameter UoM:

Processes Associated with this Release Point

Process ID	SCC

P201	10300101

P202	10201302

P202-1	10201302

Goose Neck
Release Building A
38.870926

ACTUAL CUBIC FEET PER
MINUTE

Operating Status:
Operating Status Year:
Longitude Measure:

Exit Gas Temperature
Measure (F):

Operating
2017

Control

CTRLB

Controls Associated with this Release Point

Control Path

PTHB

Figure 4-17. Editing a Release Point

Washingtoa DC 99999
2022 Emissions Report
Agency: DOEE

Release Point Information

Report Summary
Report History
Quality Checks
Report Creation Log
Monthly Fuel Reporting
Data Bulk Entry
^Facility Inventory

Facility Information
Emissions Units

Control Devices
Control Paths
"Emissions Inventory

» B201
~ B202

@ Release Point ID:'

© Release Point Description:
© Release Point Type:'

© Latitude Measure:

© Exit Gas Velocity Measure:*
© Exit Gas Flow Rate Measure: *
© Exit Gas Temperature Measure:'

© Stack Height Measure:*

© Stack Length Measure:

RP2

Release BuilaingA
Goose Neck
38.870926

20
141

© Operating Status:'
© Operating Status Year:
© Fence Line Distance Measure:
© Longitude Measure:

© Exit Gas Velocity UoM:

© Exit Gas Flow Rate UoM:

© Stack Diameter Measure:
© Stack Width Measure:

Operating
2017

FPM

V





FPS

3

FT
FT

Processes Associated with this Release Point

Controls Associated with this Release Point

Process ID

P201
P202

SCC

10300101
10201302

Control

CTRLB

Control Path

PTHB

4.2.4 Control Devices Page

Appendix A in this document explains the concepts surrounding controls. You should familiarize
yourself with that section before proceeding to set up your facility's controls. Depending on your
control set up, you will have the choice to work in the control device effectiveness and control device
pollutant removal efficiencies of your control equipment either at the individual control level, or at the
path level. While you are highly encouraged to provide the data at the individual equipment level, a
very complex control set up with combinations of controls in sequence and in parallel may make it more

35


-------
tenable for you to report control efficiencies at the path level. Your SLT may require you to provide
more detailed information, so you should check with your SLT authority before creating the controls and
control paths portion of your emissions report.

From the left-hand side menu, click on "Control Devices" under the "Facility Inventory" heading. If this
is the first NEI reported in CAERS, because we are changing how controls should be reported, previously
reported control data will not be prepopulated in your current year report. However, once you have
entered control equipment data, you will see a list of control devices associated with the facility (Figure
4-18).

Figure 4-18. Control Devices Page

Agency ID: 999999
My Facility Inc.

Report Facility & Emissions 1 nformation Perform Quality Checks Submit to SLT Authority
• • •

Approved by SLT Authority

123 MyFacility Road
Washington. DC 99999
2022 Emissions Report
Agency: DOEE





Control Devices









Report Summary

Control ID Control Description Operating Status



Report History

CTRLB Operating

i

Quality Checks



+

Report Creation Log





Monthly Fuel Reporting
Data Bulk Entry
~Facility Inventory

Facility Information
Emissions Units

Control Devices <

Control Paths
~Emissions Inventory
» B201
> B202





EPA Home | MyCDX | Accessibility Notice | Privacy and Security Notice

•	To add a new control device, click on the "+" sign at the bottom right of the list of controls. This
will take you to a blank control page (Figure 4-19). As with other sub-facility components, drop-
down menus are available for fields that require a selection. For example, to select the
operating status click on the gray arrow icon. Note that the control ID for each individual
control must be unique within the facility. On the control's page, you will add the percent
effectiveness. To ensure adding all relevant information, QA check messages will appear for
data fields that are required, for value ranges (for example, percent effectiveness must be less
than 100%), and for other errors. Click on "Save" to add the new control to the list of existing
controls. Now that the control has been added to the list of controls, you can edit it and
associate it to paths and pollutants.

•	To edit an existing control device, click on the control device ID from the list of controls. This
will take you to that control device's information page (Figure 4-20). Click on "Edit" which will
open the edit screen for the control (Figure 4-21).

36


-------
Figure 4-19. Adding a New Control

Agency ID: 999999
My Facility Inc.
123 MyFadlity Road
Washington. DC 99999
2022 Emissions Report
Agency: DOEE

Report Facility & Emissions Information
•	

Perform Quality Checks

Submit to SLT Authority

Approved by SLT Authority

Control Device Information

Report Summary
Report History
Quality Checks
Report Creation Log
Monthly Fuel Reporting
Data Bulk Entry
»Facility Inventory

Facility Information
Emissions Units
Release Points
Control Devices
Control Paths
^Emissions Inventory

~	B201

~	B202

0 Control ID:'
© Control Measure: *
© Control Description:

© Control Number Operating Months:
© Control Start Date:

© Control End Date:

© Control Upgrade Description:

Control 3

Catalytic Afterburner

yyyy-mm-dd
yyyy-mm-dd

is

IS

) Operating Status:'
) Operating Status Year:'

© Percent Control Effectiveness:
© Control Upgrade Date:

IE

EPA Home | MyCDX | Accessibility Notice | Privacy and Security Notice

Figure 4-20. Example of a Page for a Control Device

2022 Emissions Report
Agency: DOEE

Report Summary
Report History
Quality Checks
Report Creation Log
Monthly Fuel Reporting
Data Bulk Entry
^Facility Inventory
Facility Information
Emissions Units

Control Devices
Control Paths
'Emissions Inventory
~ B201

Control ID:

Control Measure:

Control Description:

Control Number Operating
Months:

Control Start Date:

Control Upgrade
Description:

CTRLB
Dry Scrubber

Control Device Information

Operating Status:	Operating

Operating Status Year:	2018

Percent Control
Effectiveness:

Control Upgrade Date:

Control End Date:

Control Device Assignment

Control Device Pollutants





Identifier

Component

Type

Pollutant Name

Code CAS ID % Reduction Efficiency

Kmu

B201

Boiler Building A

Emissions Unit

Carbon Monoxide

CO 630-08-0 99

Of na

P201

Power Anthracite

Emissions Process

+

RP2

Release Building A

Release Point



Paths Associated with this Control

Path Identifier

PTHB

EPA Home | MyCDX | Accessibility Notice | Privacy and Security Notice

37


-------
Figure 4-21. Editing a Control Device

I US EPA-CAERS Combined Air E X +

C A cdxappstest.epacdx.net/cef-web/#/fadlity/2070/report/2160/control/5734

Control Device Information

- ~ X

is 8201
~ B202

© Control ID:*	CTRIB

© Control Measure:'	Dry Scrubber

© Control Description:

© Control Number Operating Months:	12

© Control Start Date:	2018-12-01

© Control End Date:

© Control Upgrade Description:

10
M

© Operating Status:*
© Operating Status Year:

© Percent Control Effectiveness:
© Control Upgrade Date:

Operating
2018

Control Device Assignment

Control Device Pollutants

Identifier

Component

Type

Pollutant Name

Code CAS ID % Reduction Efficiency



B201

Boiler Building A

Emissions Unit

Carbon Monoxide

CO 630-08-0 99

ST on

P201

Power Anthracite

Emissions Process

+

RP2

Release Building A

Release Point



o To associate a pollutant with this control device, click on the "+" sign at the bottom right of
the "Control Device Pollutants" box. You will be taken to a pop-up window that will allow
you to select a pollutant. Start typing the name of the pollutant or its abbreviation (for
example, PM) and a list of possible pollutants will appear for you to make your selection
(Figure 4-22). When you have chosen the pollutant and entered the control percent
reduction efficiency, click "Save" and you will be returned to the control device's
information page. Now, the pollutant you entered will appear in the list of pollutants.

38


-------
Figure 4-22. Associating a Pollutant and Control Efficiency to a Control

Release Points _





Q Control Up

Control Devices

Control Device Pollutant



^Emissions Inventory





^ g2oi Comment

Pollutant:*



» B202

This field is required.





Q Percent Reduction Efficiency:*











ol Device Pollutants

Identifier



^SID % Reduction Efficiency

B201



0-08-0 99 Ef i

P201



+

RP2







Paths Associated with this Control



Path Identifier Path Description



PTHB





EPA Home | MyCDX | Accessibility Notice | Privacy and Security Notice

•	Control device assignment: The Control Device Assignment box will show the components that
are related to the control. For example, it will show the release point, emission unit, and
emission process that are used by the control. You cannot do edits on this list in this screen.
Instead, you have the ability associate the control with these components through the Control
Paths page (see Section 4.2.5).

•	Paths associated with this control: The path(s) that contain this control are also listed on the
control device's page. These are also not editable from this screen. You must go to the Control
Paths link on the left-hand side menu on your screen to edit paths (see Section 4.2.5).

•	To delete a control device, if you find you have started to enter a new control in error, you can
click "Cancel" to avoid saving the changes, and you will be returned to the "Control Devices"
page. Please do not delete a control device if it was reported in a previous year. Instead, mark
it as temporarily or permanently shut down to avoid having it remain idle in your facility
inventory.

•	Important additional considerations about control devices:

o Finding individual control equipment information: Resources to find out information about
your control release point apportionment (previously control capture efficiency) and control
efficiency can include vendor specifications, and trade associations that may be able to
provide you with averages for the industry. However, you should consult with staff at your
SLT with your questions about controls and your planned approach to make sure they
approve of it before you have submitted the data,
o Use of the control efficiency percentage: Note that the overall percent controlled, as

described in Section 4.3.2.2, will be the value factored into the emissions calculations when
the calculation method calls for its application. For example, the overall control % will not
be applied to your calculations if you are reporting stack test data,
o New but inactive control devices: As with other sub-facility components, please do not
create a new control device in your report, and then mark it as temporarily or permanently
shut down. If you have a new control device that will report emissions in a future year, add
it in that future year report.

39


-------
o Relabeling pitfall: Please do not relabel current control devices in the bulk upload template
with new ID's. The system will not recognize these controls as existing, effectively adding
control to your facility instead of simply replacing the ID's. If you do, your facility inventory
of record with EPA will reflect additional controls and potential emissions that do not really
exist in your facility. Your efforts in this regard will help us keep your facility inventory up to
date.

o Choosing IDs: If your SLT allows it, the reporter can choose the ID for the control

equipment. There is a requirement that no two control devices be labeled with the exact
same ID. You should choose ID's that you will not find confusing to use in future. Consult
your SLT on any rules the SLT may have regarding IDs. For example, the SLT may want your
control device to be labelled by a specific naming convention.

4.2.5 Control Paths Page

Control devices will be reported differently than in years prior to the 2019 inventory year, and
this includes associating controls with specific paths. Appendix A in this document explains the concepts
surrounding controls and control paths. You should familiarize yourself with that section before
proceeding to set up your facility's control paths.

By clicking on the left-hand side menu, click on "Control Paths" under the "Facility Inventory" heading.
You will be taken to the control paths page (Figure 4-23), where you will be able to see a list of control
paths associated with that facility. If the first time you are reporting paths, you will not see any paths
displayed, and you will be creating paths and populating that list from this screen.

•	To add a new control path, click on the "+" sign. This will take you to a blank path page (Figure
4-24). You will be asked to enter a Path ID, which should be unique within the facility, and a brief
description to help identify which path it is. Click "Save" and this will take you back to the Control
Paths page. Now your new path will appear in the list of existing paths and you will be able to edit
it.

•	To edit a control path, click on its ID from the "Control Paths" page and you will be taken to that
path's information page (Figure 4-25). Click on "Edit" to edit the path information (Figure 4-26).
When you are finished with your edits click "Save". This will take you back to the information
page for that path. If the changes are an error, you can click "Cancel".

o Adding control devices to a path: Click on the path you want to add controls to from the
"Control Paths" page. This will take you to that path's information page (Figure 4-25). On
the bottom right of the "Control Path Assignment" box, click on the This will take you
to a pop-up window that will allow you to place either a control or a child path into the path
you are editing (Figure 4-27). Enter the sequence number for its position in the path with
respect to other controls. For example, if it is the second control device in the path you will
enter 2.

Next, enter either a control device or a control path (you must select one or the other, but
not attempt to enter both a control and a path here). Drop-down menus will allow you to
select either an existing control device or an existing path. Note that you must enter the
controls first, so they will appear in the corresponding menu. You must build smaller
(children) paths first, before building larger (parent) paths that contain children paths.

40


-------
Figure 4-23. Control Paths Page

Agency ID: 999999
My Facility Inc.
123 MyFacility Road
Washington, DC 99999
2022 Emissions Report
Agency: DOEE

Report Facility & Emissions Information

Perform Quality Checks

Submit to SLT Authority

Approved by SLT Authority

Report Summary
Report History
Quality Checks
Report Creation Log
Monthly Fuel Reporting
Data Bulk Entry
"Facility Inventory
Facility Information
Emissions Units
Release Points
Control Devices
Control Paths <

"Emissions Inventory

Path Id

PTHB

EPA Home | MyCDX | Accessibility Notice | Privacy and Security Notice

Figure 4-24. Adding a New Path

Agency ID: 999999
My Facility Inc.
123 MyFacility Road
Washington. DC 99999
2022 Emissions Report
Agency: DOEE

Emissions Units
Release Points
Control Devices
Control Paths

"Emissions Inventory

~	B201

~	B202

Report Facility & Emissions Information
•	

Perform Quality Checks

Submit to SLT Authority

Approved by SLT Authority

Report Summary
Report History
Quality Checks
Report Creation Log
Monthly Fuel Reporting
Data Bulk Entry
"Facility Inventory

6 Path ID:'

© Path Description:

Control Path Information

Q Percent Path Effectiveness:

EPA Home | MyCDX | Accessibility Notice | Privacy and Security Notice

41


-------
Figure 4-25. Example of a Page for a Control Path

Agency ID: 999999
My Facility Inc.
123 MyFacility Road
Washington. DC 99999
2022 Emissions Report
Agency: DOEE

Report Facility & Emissions Information

Perform Quality Checks

Submit to SLT Authority

Approved by SLT Authority

Report Summary
Report History
Quality Checks
Report Creation Log
Monthly Fuel Reporting
Data Bulk Entry
^Facility Inventory

Facility Information

Emissions Units

Control Devices

Control Paths
'Emissions Inventory

»B201

Path ID:

Path Description:

Control Path Information

Percent Path Effectiveness: 97

Control Path Assignment

Control Path Pollutants

Sequence Number

Assignment

% Apportionment

¦ «¦

Pollutant Name

Code CAS ID % Reduction Efficiency



1

CTRLB

100

B* fin

Carbon Monoxide

CO 630-08-0 99

m

+

+

EPA Home | MyCDX | Accessibility Notice | Privacy and Security Notice

Figure 4-26. Editing a Path

AgencyID: 999999
My Facility Inc.
123 MyFacility Road
Washington. DC 99999
2022 Emissions Report
Agency: DOEE

Report Facility & Emissions Information

Perform Quality Checks

Submit to SLT Authority

Approved by SLT Authority

Report Summary
Report History
Quality Checks
Report Creation Log
Monthly Fuel Reporting
Data Bulk Entry
~Facility Inventory

Facility Information
Emissions Units
Release Points

Control Paths
~Emissions Inventory
» B201
~ B202

©Path ID:

© Path Description:

Control Path Information

) Percent Path Effectiveness:

Control Path Assignment

Control Path Pollutants

Sequence Number

Assignment

% Apportionment

¦¦¦

Pollutant Name

Code CAS ID % Reduction Efficiency



1

CTRLB

100

BD

Carbon Monoxide

CO 630-08-0 99

Of ffi

+

+

EPA Home | MyCDX | Accessibility Notice | Privacy and Security Notice

42


-------
Figure 4-27. Adding a Path Assignment

Agency ID:999999
My Facility Inc.
123 MyFacility Road

Report Facility

Control Path Assignment





¦

Approved bySLT Authority















0 Enter the Sequence Number*

1







2022 Emissions Report
Agency: DOEE



6 You must select either a Control or a Control Path:*









Report Summary

O Path ID:*

Control Control Path









Report History

-

-









© Path Desc











Quality Checks



6 % Path Apportionment (of Control or Sub-Path) *

1







Report Creation Log























¦¦¦I

Monthly Fuel Reporting







Cancel



WBSMmm

Data Bulk Entry

























~Facility Inventory



Control Path Assignment





Control Path Pollutants

Release Points
Control Devices

Sequence Number Assignment % Apportionment

Pollutant Name

Code

CAS 1D % Reduction Efficiency

1

CTRLB 100 B* i

Carbon Monoxide

CO

630-08-0 99 Bf 1

Control Paths
~Emissions Inventory



+







+

» B201













» B202

















EPA Home | MyCDX | Accessibility Notice | Privacy an

d Security Notice







Enter the control apportionment percentage. For example, if the control device or path you
have selected will be first in the sequence and will be receiving 100% of the emissions from the
emissions process, you would enter 100. If a control receives all emissions from the previous
control device or path in the sequence, enter 100. If the control will be receiving 50% of the
emissions from the previous control or path in the sequence, enter 50. Click "Save" to go back
to that path's screen. Your assignment should appear in the list of assignments.

Here is an example of how data would be entered for a facility with complex controls (see the
example facility in Appendix A, 11.2A. 4). For the example facility, controls are configured as
shown in Figure 4-28. Additionally, Control Device 1 sends 60% of its emissions to Path 1 and
40% of its emissions to Control Device 3. Controls 2 and 4 are configured in sequence, and
would be added to Path 1 from Path l's screen as shown in Table 4-1. In Path 2, Path 1 and
Control 3 run in parallel and thus, have the same sequence number. Path 2 would include the
following as shown in Table 4-2 where Path 1 and Control 3 have been highlighted.

43


-------
Figure 4-28. Example of a Facility with Complex Controls

Path 3

L

Table 4-1. Example of Data Entry for Controls in Sequence for Path 1

Control or Control Path

Sequence Number

% Apportionment

Control 2

1

100

Control 4

2

100

Table 4-2. Example of Data Entry for an Assignment including a Control and a Path Running in Parallel
for Path 2

Control or Control Path

Sequence Number

% Apportionment

Control 1

1

100

Path 1

2

60

Control 3

2

40

Control 5

3

100

•	To associate the control path to one or more processes and release points, select the relevant
unit from the "Emissions Inventory" menu on the left-hand side or from the list in the "Emissions
Unit" page under "Facility Inventory". Then, choose the relevant process for that unit that you
want to associate and follow the instructions in Section 4.3.2 on how to associate a release points
with processes.

•	Important additional considerations about control paths:

44


-------
o Relationship between control devices, children, parent, and main path: It is important to
remember that a path can include one or more controls as well as another path. While
there may be many "children" paths within "parent" paths, there should be one main path
between each process, and the controls between it and its release point(s). As you create
paths, keep in mind that while one path may contain other paths, ultimately, you will want
to ensure that you've created a path that includes all controls leading from any process to a
release point. Each relationship between an emissions process and a release point (i.e. the
release point apportionment) can only be associated with one control path. All processes
from a unit to a release point can share the same path,
o Relabeling pitfall: Please do not relabel current control devices or control paths in the bulk
upload template with new ID's. The system will not recognize these controls as existing,
effectively adding control to your facility instead of simply replacing the ID's. If you do, your
facility inventory of record with EPA will reflect additional controls and potential emissions
that do not really exist in your facility. Your efforts in this regard will help us keep your
facility inventory up to date,
o Avoid idle paths: Empty paths add unnecessary data to your report. You are encouraged to

create only paths that will actually be used, i.e. that contain controls in them,
o Choosing IDs: If your SLT allows it, the reporter can choose the ID for the control path.
There is a requirement that no two control paths be labeled with the exact same ID. You
should choose ID's that you will not find confusing to use in future. Consult your SLT on any
naming conventions they may require you to use to label control paths.

4.3 Emissions inventory

The left-hand side menu of the application shows a list of units for the facility under "Emissions
Inventory". You can click on the arrow to the left of the Unit ID to show a list of processes associated
with that unit. Click on any one of those units or processes to show the unit's information.

4.3.1	Units

Click on the unit you are interested in. This will take you to that unit's information page. Click
on the "Edit" button at the top right of the screen to make changes to the emissions unit information.
For more information on adding or editing a unit, see Section 4.2.2.

4.3.2	Processes

From the left-hand side menu, click on the relevant unit. Once you are in that unit's information
page, you will be able to add or edit a process.

• To add a process, click on the "+" at the bottom of the list of processes in the "Processes

Associated with this Emissions Unit" box. This will take you to a process page (Figure 4-29) where
you can enter all relevant information for that process. Drop-down menus will assist you in
selecting some data fields. Error messages will appear for items that have been entered
incorrectly or for missing fields that are required.

45


-------
Figure 4-29. Adding a New Process

Mytown,GA 12345
2020 Emissions Report
Agency: GADNR

Report Summary
Report History
Quality Checks
Data Bulk Entry
~Facility Inventory

Facility I nformation
Emissions Units
Release Points
Control Devices
Control Paths

~Emissions Inventory

Process Information

© Unit ID:
G Process ID:*

G

Process Description:
© SCC:*

0 SCC Description:

© Operating Status:*
©

Operating Status Year:*

Search for Source Classification Code

Operating Details

© Avg. Days per Week: *	© Hours per Period: *

© Avg. Hours per Day: *	© Avg. Weeks per Year:*

© Summer Operating Percent:*	©Winter Operating Percent:*

© Spring Operating Percent:*	© Fall Operating Percent:*

Reporting Period













© Reporting Period:*

Annual

v © Operating Type: *

-

©

-









Throughput Parameter:



©

Throughput Material:*



v © Throughput Value:*



© Throughput UoM: +

-











© Fuel Material:



v © Fuel Value:



© Fuel UoM:

V

Note that your process Source Classification Code (SCC) can be found via search. Click on the
"Search for SCC Code" button and enter a search term (for example, boiler). The search will be
performed and return a list of options for you to choose from. Click on the SCC you want to use
Note that the SCC Level descriptions for that code will pre-populate in the SCC Description box.
You may also enter an SCC if you already know it (for example, 10100201). See Figure 4-30.

The form will crosscheck that the code you are entering is a valid point source code and is a
code that has not been retired before the inventory year you are reporting. A warning will be
displayed if the selected SCC is being retired the year of your report, or in the future, but you
will still be able to use that code. However, if the SCC you select was retired before the year of
your report, you will see a critical error. If you want to see a full list of codes or perform
different searches, go to https://epa.gov/scc.

46


-------
Figure 4-30. SCC Search











Select an SCC Code











Search for an SCC Code by any of the SCC levels: J, 2.3. or 4. Text. Code Number. Short Name, or Description. You can do a more extensive search at









SCCCode Description Sector





10100101 Combustion Boilers > Electric Generation > Anthracite Coal. Pulverized > Boiler Fuel Comb • Electrk Generation •





Coal





10100102 £XTern*' Combustion Boilers > Electric Generation»Anthracite Coal > Boiler. Traveling Grate (Overfeed) Stoker Fuel Comb - Electric Generation -





Coal





10100201 External Combustion Boilers » Electrk Generation > Bituminous Coai. Pulverized > Boiler, Wet Bottom Fuel Comb-Electrk Generation -





Coal





10100202 Erf*™*1 Combustion Boilers » Electric Generation »Bituminous Coal. Pulverized » Boiler. Dry Bottom Fuel Comb • Electric Generation -





Coal





10100203 **twna' Combustion Boilers » Electric Generation > Bituminous Coal > Boiler, Cyclone Furnace Fuel Comb • Electrk Generation -





Coal





10100204 External Combustion Boilers ~ Electric Generation > Bituminous Coal » Boiler. Spreader Stoker Fuel Comb • Electric Generation -





Coal





10100205 External Combustion Boilers > Electric Generation > Bituminous Coal > Boiler. Traveling Grate (Overfeed) Fuel Comb • Electrk Generation -





Stoker Coal





10100211 Combustion Boilers > Electrk Generation > Bituminous Coal > Boiler. Wet Bottom Tw^entiai-Ared Fuel Comb - Electrk Generation -





Coal





10100212 Extern*1 Combustion Boilers > Electrk Generation > Bituminous Coal. Pulverized » Boiler. Dry Bottom Fuel Comb - Electrk Generation -





Tangential fired Coal





101002 IS £xt*fn*< Combustion Boilers > Electrk Generation > Bituminous Coal > Cell Burner Fuel Comb - Electrk Generation -





Coal





10100217 Combustion Boilers > Electrk Generation > Bituminous Coal» Boiler. Atmospherk f luidized Bed Fuel Comb • Electrk Generation -





Combustion: Bubbling Bed Coal













Once you add a process, it will appear in the list of processes associated with that unit on the
unit's information page.

• To edit a process, from the unit's information page, you can also edit a process. Click on the
process you want to edit. This will take you to a page with all the information about that process
(Figure 4-31). Click on the "Edit" button at the top right of the screen to make changes to the
process information (Figure 4-32). You can edit operating details and reporting period
information by clicking "Edit" in each of those boxes. Note that this version of CAERS is for annual
reporting only. Future versions of the system will offer more reporting periods. Click "Save" when
your edits are finished. Click "Cancel" if you find your edits are an error and wish to discard them
o Editing throughput: When throughput for a process is changed, the CAER system will
automatically calculate the emissions for all pollutants associated with the process, where
this is possible given the calculation method selected for each pollutant. A message in a
green box will appear at the top right of the screen indicating that calculations were
successful. If a calculation is not possible, an orange or red box will appear with an error
message indicating the problem encountered with the calculation,
o Entering fuel data: Certain fuel-based processes must be reported by using the fuel

material listed in the description. You will be asked to enter the fuel (e.g. diesel, natural gas,
anthracite) as per the fuel listed for the process SCC, the amount of fuel used (value), and
that fuel's heat content, together with units of measure. Because it is highly likely that the
fuel material you report will be the same as the throughput material you would have
reported, you can enter the fuel and then copy it as the throughput material for that
process. To do so, click on "Copy Fuel Data to Throughput Data Fields". Check that the fuel

47


-------
type and units of measure match the fuel listed in the SCC. For example, SCC 10200101 has
the following description: External Combustion, Industrial: Boilers, Anthracite Coal,
Pulverized Coal. The fuel reported would be "Anthracite", and it is likely that you would
have listed the throughput material for this SCC as "Anthracite" so you can simply click to
copy it in. You might, in addition, choose to use an alternative throughput for one of the
pollutants for this process in order to use an emission factor to match that alternative
throughput, as described in the next bullet. Refer to Appendix C, Section C.l for default
heat content values. CAERS will prepopulate the default heat content value if the units of
measure the user enters match up exactly to those as listed in the default heat content list,
o Entering alternative throughput: When using emission factors with different materials
and/or units of measure for different pollutants for the same process (SCC), CAERS allows
you to enter an alternative throughput. CAERS will create a copy of your original process
when you click on the "Add Alternative Throughput for this Process" button at the top of the
screen for that process. A pop-up window will appear, asking if you are sure this is what you
want to do. If you accept, you will be taken to a new screen where all your process data has
been prepopulated for you except for the process ID, throughput data fields, and emissions.
From there, you can enter a new ID, your alternative throughput data, and list the pollutants
for which you'll be using this throughput to calculate emissions.

Figure 4-31. Example of a Page for a Process

Add Alternative Throughput for this Process

Process Information

Unit ID:

8201





Process ID:

P201

Process Description:

Power Anthracite

Operating Status:

Operating

Operating Status Year:

2017

SCC:

10300101

SCC Description:

External Combustion Boilers > Commercial/Institutional > Anthracite Coal > Pulverized Coal

Comments:







Operating Details

Avg. Days per Week:
Avg. Hours per Day:
Avg. Weeks per Yean

5
8

52

Hours per Period: 2080
Winter Operating Percent: 25
Spring Operating Percent: 25

Summer Operating Percent:
Fall Operating Percent:

25
25

Reporting Period

Reporting Period:	Annual	Operating Type:	Routine	Throughput Parameter:	Input

Throughput Material:	Anthracite	Throughput Value:	100	Throughput UoM:	TONS

Fuel Material:	Anthracite	Fuel Value:	Fuel UoM:	TONS

Heat Content Ratio:	25.09	Heat Content Ratio Numerator:	MILLION BTUS

Emissions Associated with this Process	Release Points Associated with this Process

Pollutant Name	Code	CAS ID	Release Point	Release Type	Control Path	%

Carbon Monoxide	CO	630-08-0	1	RP2	Goose Neck	PTHB	100% Bf i

Nitrous Oxide	N20	®	Total % Apportionment of Emissions	100%

Volatile Organic Compounds	VOC	fi	+

+	Note: Each process must allocote exactly 100% of its emissions to one or more release points before the report can be submitted.

Controls Associated with this Process

48


-------
Figure 4-32. Editing a Process

Agency ID: 99999999
Facility Inc.

123 Main Street
Mytown. GA12345
2020 Emissions Report
Agency; GADNR

Report Summary
Report History
Quality Checks
Data Bulk Entry
'Facility Inventory

Facility Information
Emissions Units
Release Points
Control Devices
Control Paths

~Emissions Inventory

» B001

Report Facility & Emissions Information

Perform Quality Checks

Submit to SLT Authority

O Unit ID:
Q Process ID:'

©

Process Description: *
©SCC:"

0 SCC Description:

B001
PR001

Boiler for Anthracite

Approved by SLT Authority

Add Alternative Throughput for this Process

Process Information

© Operating Status:'

Operating

Operating Status Year:"

10200101

External Combustion > Industrial: Boilers > Anthracite Coal > Pulverized Coal

Search for Source Classification Code

Operating Details

Avg. Days per Week:

5

Hours per Period:

2080





Avg. Hours per Day:

8

Winter Operating

25

Summer Operating

25





Percent:



Percent:



Avg. Weeks per Year:

52

Spring Operating

25

Fall Operating Percent:

25





Percent:









Reporting Period

•	To delete a process, from a unit's page, you should only delete a process using the garbage can
icon if you added it to this year's report and that addition was an error. If the process existed in a
previous year's report, and is no longer in use, you can click on its ID and change its status from
"Operating" to "Permanently Shutdown". Once you have done so, the data on the operating
details and reporting period for that process will be hidden from view. However, the "Release
Point Apportionment" and "Controls Associated with this Process" will remain.

•	Other items in the process page: In this page you will also see pollutants, release points, and
controls associated with the process.

o To add a release point to a process, see Section 4.3.2.1. Associated control paths and

controls will appear once the process has been associated to the release point as described
in Section 4.3.2.1.

o To add pollutants to a process, see Section 4.3.2.2.

o To add controls, see Section 4.2.4.

•	Important additional considerations about processes:

o New but inactive processes: As with other sub-facility components, please do not create a
new process in your report, and then mark it as temporarily or permanently shut down. If
you have a new process that will report emissions in a future year, add it in that future year
report.

o Relabeling pitfall: Please do not relabel current processes in the bulk upload template with
new ID's. The system will not recognize these processes as existing, effectively adding
processes to your facility instead of simply replacing the ID's. If you do, your facility
inventory of record with EPA will reflect additional processes and potential emissions that

49


-------
do not really exist in your facility. Your efforts in this regard will help us keep your facility
inventory up to date.

o Choosing IDs: If your SLT allows it, the reporter can choose the ID for the process. There is
a requirement that no two processes for the same unit be labeled with the exact same ID.
You should choose ID's that you will not find confusing to use in future. Consult your SLT on
any naming conventions they may require you to use to label processes,
o Caution with processes for alternative throughput: When using the alternative throughput
option, the system will recognize that the new throughput is in a copy of an existing process.
Be careful not to alter the process copy, or the system may interpret it as a different process
and flag it for any relevant errors. Additionally, if the copy process is altered, and it is for an
SCC where fuel is required, the system will require you to enter fuel use for that process
again, and fuel use will be double counted. Similarly, a process copy should only list the
pollutants that are using the alternative throughput, otherwise, emission from pollutants
may be compounded.

4.3.2.1 Associating a Process to a Release Point

Go to the process information page (Figure 4-31). You can get there by clicking on the
corresponding unit from the left-hand side menu, and then clicking on the relevant process ID. First, in
the "Release Points Associated with this Process" box, click on the "+" sign to add a release point
associated with the current process. A pop-up window will appear requesting information about the
release point, and the percentage of the process' emissions being directed to that release point (Figure
4-33). If there are no controls between the process and a release point, you do not have to enter a
control path. You will simply apportion the corresponding emissions to the release point.

If there are controls to associate the control path to one or more processes and release points, you
should associate them here. Note that the control and path assignments should have been defined
before attempting this step (Sections 4.2.4 and 4.2.5). This will allow you to select from existing release
points, and control paths. All emissions from the process must be apportioned to a release point so that
100% of total emissions have been assigned to one or more release points.

Figure 4-33. Release Point Apportionment

Release Point Apportionment

Select a Release Point'

RP001- Building 1

Select a Control Path (optional)

t
t-

© Enter the Emission Percentage"

Save I Cancel

50


-------
After entering the relevant information, click "Save". Now you will be able to see, in the "Controls
Associated with this Process" box at the bottom left of the screen, the path you have associated with
the release point and process.

You will not be able to edit the controls associated with the process from this page. If you need to edit
the controls and/or paths, you must ensure you have entered the relevant control devices and their
paths as in the steps described above, and that you have associated them to the relevant process.

4.3.2.2 Entering and Calculating Emissions

In the page for that process, go to the "Emissions Associated with this Process" box in the lower
left side of the screen (Figure 4-32). Click the "+" sign to add emissions. This will take you to a new
pollutant page (Figure 4-34). In the "Pollutant" data field start typing in the name, code, or CAS number.
The form will assist in finding the name of the pollutant. Once you have found the pollutant you are
looking for, select it. The form will then prepopulate the other pollutant data fields: Pollutant Code,
Pollutant Name, and CAS ID if it exists. For example, typing in sulfur will render Sulfur Hexafluoride -
SF6, and Sulfur Dioxide - S02-9-5-7446. Note that some pollutants, such as Volatile Organic Compounds
(VOC) do not have a CAS number because they are groups of pollutants, as opposed to single pollutants.
You will still be able to select such pollutants even if the CAS number field appears blank.

EPA augments triannual reports to reflect Hazardous Air Pollutants (HAPs). Alternatively, if you wish to
reflect your own HAP calculations instead of EPA's, you will be able to do so by entering your own HAP
data when entering pollutant emissions (see Section 4.3.2.2). You are encouraged to provide HAP
information even if your SLT does not require it, so that you avoid EPA having to estimate that
information, which may not be as accurate as your own information.

Note that for any estimation method that does not involve an emission factor and thus, does not occupy
the CAERS calculator, you will be required to enter a comment and provide an attachment. Only one
attachment is required for your entire report, but it should contain an explanation of each of the
situations where a factor was not used. Check with your SLT staff to ensure you provide them with the
information they require before creating the attachment and submitting it with your report, and in the
correct format they require. Your SLT may require, specifically, that your attachment be an excel file
showing all the data used in your calculations so that the SLT staff person can replicate your estimates.
If you do not provide all the relevant information, your SLT may return your report to you.

51


-------
Figure 4-34. Adding a New Pollutant

Report Summary
Report History
Quality Checks
Data Bulk Entry
~Facility Inventory

Facility I nformation
Emissions Units
Release Points
Control Devices
Control Paths

~Emissions Inventory

» BOOl

Unit ID:	BOOl

Process ID:	PR001

Throughput Material:	Anthracite

Throughput Parameter:	Input

Fuel Material:	Anthracite

Reporting Period:
Throughput Value:

Fuel Value:

Heat Content Ratio:

Annual
100

Operating Status:
Throughput UoM:

Heat Content Ratio
Numerator:

Operating
MILLION BTUS

MILLION BTUS

Emission Information

6 Pollutant:4
© Pollutant Name:
0 Calculation Method: "

© Emission Factor:*

© Pollutant Code:
0 CAS ID:

Emission Factor Description:

0 Emission Factor Numerator UoM:

© Overall Control %:

0 Total Emissions:*

Emission Factor Denominator UoM:*

0 Emissions UoM:*

~ I prefer to calculate the total emissions of this pollutant.

Calculate Emissions I Cancel

EPA Home | MyCDX | Accessibility Notice | Privacy and Security Notice

Next, select calculation method from the drop-down menu (Figure 4-35). The form will require the user
to enter specific data fields according to the calculation method selected.

• Using emission factors: There are multiple options in CAERS for using emission factors.

o If you have selected a U.S. EPA Emission Factor, the form will allow you to search for an
emission factor by clicking on the corresponding box under the calculation method. EPA
emission factors in CAERS can also be searched in US EPA's WebFIRE. However, the list of
EPA emission factors in CAERS may not contain factors listed in WebFIRE if those factors are
of a quality "U". CAERS Version 3 will show if an emission factor has been revoked, and is
thus, no longer appropriate to use. For an EPA Emission Factor to be used in CAERS, the
SCC, pollutant and units of measure listed for the emission factor must match with the
throughput units of measure and pollutant you are reporting exactly, or the units of
measure must be easily convertible so that CAERS can do the conversion for you. For
example, you may use an emission factor in tons/pound, for throughput measured in
pounds, or any weight unit of measure that can be converted into from pounds. You may
not be able to use a factor in tons/gallon when your throughput is in hours. Finally, you may
not be able to use an emission factor if the SCC listed for that factor has been retired. If you
and your SLT, in consultation with EPA, determine that an EPA factor from a retired SCC is
still valid and can be used for a process, you should select "Other Emission Factor" as your
calculation method and enter it there. We encourage you to discuss this with your SLT staff
before you enter the data to your report to avoid having the report sent back to you for
corrections. Some emission factors have been corrected by EPA, and you may get an error

52


-------
message requiring you to review your existing factor or select a new one. If you feel there
are errors in an emission factor listed in CAERS, please reach out to your SLT. For EPA
factors, the system will flag a factor from your previous year report, or upon bulk upload, if
it doesn't recognize the factor you have used as an EPA factor. If that is the case, you should
search and select the correct factor or select another calculation method,
o S/L/T Emission Factor can be used as well by entering an SLT specific and SLT approved
emission factor for your process. CAERS will prepopulate SLT factors from other states if
your SLT allows you to use them, you can select your factor from there or enter it yourself.
You should discuss the factor you intend to use if selecting this option with your SLT to
ensure it is appropriate for use with your process.

Figure 4-35. Selecting a Calculation Method

Control Devices

Emission Information







Control Paths









~Emissions Inventory 0 Pollutant:+

Q Pollutant Code:







~ BOOl

0 Pollutant Name:









0 CAS ID:

















0 Calculation Method: *

I '1





© Emission Factor:*

Continuous Emission Monitoring System









Emission Factor based on data available peer reviewed literature







© Emission Factor Numerator UoM:*

Emission Factor based on Fire Emission Production Simulator (FEPS)
Emission Factor based on Regional Testing Program







0 Overall Control %:

Engineering Judgment







0 Total Emissions:*

Manufacturer Specification
Material Balance

Other Emission Factor (no Control Efficiency used)







Comments:

Other Emission Factor (pre-control) plus Control Efficiency
S/L/T Emission Factor (no Control Efficiency used)
S/L/T Emission Factor (pre-control) plus Control Efficiency
S/L/T Speciation Profile



1





Site-Specific Emission Factor (no Control Efficiency used)
Site-Specific Emission Factor (pre-control) plus Control Efficiency



1











EPA Home |

Stack Test (no Control Efficiency used)





o Formulas: Note that some factor searches will return formulas. The form will require
the user to then supply additional parameters for that formula. For example, sulfur
content %. If the emission factor units of measure (UoM) is different from the
throughput UoM's, the form will return an error. However, the form will perform a
simple conversion for units of the same kind (for example, weight UoM conversions
from lbs to tons). See Appendix B for more information on conversions in CAERS. After
entering all required fields, click on "Calculate Emissions" and the form will calculate the
emissions for you. A green confirmation message at the top right of your screen will
appear to indicate the calculations have been performed. Click "Save" to be taken back
to the emission unit information page,
o EPA Factors requiring additional explanation: If you have selected an EPA emission
factor because one exists but its use is not straightforward you can check the box "I
prefer to calculate the total emissions of this pollutant" located under the Emissions
UoM box, and the calculator will disengage. If you disengage the calculator, you must
enter a description of your calculation process in "Description of Calculation" box and
add the explanation in the attachment to justify the use of an alternative emission
factor or total emissions you calculated (Figure 4-36). EPA factors that may fall under

53


-------
this category include, for example: factors for retired SCCs being used for a new map to
SCC, factors within range where the factor is listed as being a mid-range value, or as
being expected to be lower than the value listed, factors not available through the
CAERS search feature but that exist in AP42 (consult WebFIRE and make sure that those
factors have not been either revoked, or marked as lower quality).

• Controls: If controls are present (associated with this process via a path), enter the overall control
efficiency for the path in the "Overall Control %" box so that CAERS can calculate the post-controls
emissions for you. For a single control this is equal to the multiplication of: (percent capture) x
(percent effectiveness) x (percent efficiency). For more than one control (including control paths)
it is the total percent of the pollutant that is removed by the controls (or control paths). You
should reach out to your SLT if you have questions about how to calculate this value for your
specific control device configuration. For a numerical example on controls and how the different
percentages are used to calculate emissions, see Appendix A, Section A.6.

Figure 4-36. Using EPA Emission Factor Alternative

Keport History
Quality Checks
Data Bulk Entry

~Facility Inventory

Facility Information
Emissions Units
Release Points
Control Devices
Control Paths

~Emissions Inventory

~ 8001

Throughput Material: Anthracite
Throughput Parameter: Input
Fuel Material:	Anthracite

© Pollutant:'

© Pollutant Name:

© Calculation Method:'

© Emission Factor:'

O Emission Factor Numerator UoM:'

© Overall Control %:

© Total Emissions:'

Description of Calculation:"

Throughput Value:

Fuel Value:	100

Heat Content Ratio:

Emission Information

Volatile Organic Compounds - VO< © Pollutant Code:
Volatile Organic Compounds	© CAS ID:

USEPA Emission Factor (no Control Efficiency used)

Throughput UoM:

Heat Content Ratio
Numerator:

MILLION BTUS

MILLION BTUS

© Emission Factor Description:

Emission Factor Denominator UoM:'

Search for Emission Factor

This factor was present in AIRS
Facility Subsystem Source

© Emissions UoM: "	LB

~ I prefer to calculate the total emissions of this pollutant

loM:	

O ^pr^er

AP-42 Factor not usable given UOM discrepancy]

5 Reporting Emissions and Facility Information Using Bulk Upload

5.1 The Bulk Upload Excel Template

If you will have relatively few changes between your previous year report and your current year
report, we encourage you to use the user interface instead of bulk upload (BU) because this may be
more time saving for you in the longer term. If you have a variety of changes, and/or your facility is very
large, BU may be the best choice for you. You should familiarize yourself with this section of the
instructions before beginning any data entry. There is a special template for bulk upload in Excel format.

54


-------
You should use extreme care when entering data into the spreadsheet making sure you have not
created an error in the template inadvertently. This section will help you avoid errors that will be time
consuming to you. You should also consult the checklist in Appendix D at the back of this user guide
before submitting your data.

Before you download your excel template, if you have submitted a previous year report, we strongly
encourage you to run the Quality Checks via the user interface. Doing so will alert you to any new QA
checks that have come online since your previous report, and you will be able to address these errors
while creating your new report. Failing to do so may result in rework of your template and more than
one upload attempt.

Also, if this is your first time using CAERS for reporting, we encourage you to enter a few items in the Ul
first, then download the template. You should see the items you edited in the Ul appear in the version
of the template you downloaded. This may help you understand how data fields are related from one
data tab to the next. Even if you plan to do all your work in the BU template, having the Ul open to
specific screens you can reference and where you can test data entry, may be extremely helpful in
understanding what and how to enter data in each tab and cell.

Note that while testing is useful, you should be aware that whatever you enter in the BU will override
data in the Ul, so you should take care not to enter some items in the Ul and some in the BU, unless the
changes in the Ul have been done before you downloaded your template.

Also, tips and tools for data entry under the "important additional considerations", that have been
explained throughout the User Interface portion of this guide (Section 4) will be helpful for bulk upload.
We strongly encourage you to review those sections before attempting to use the template, as this may
save you time and a potential rejection of your report later on.

Facilities that have reported in previous years can download an excel template, which contains their
previous year report pre-populated with your previous year annual emissions (National Emissions
Inventory) report. We strongly recommend that you make a copy of that pre-loaded template and work
with the copy, in case you need to revert to the original. You can obtain this pre-loaded template by
clicking on "Download as Template" from the Emissions Reports page (Figure 4-1). While you can
always download another copy from the Ul, having an extra copy may help you reference the previous
year report as well.

When you open your file, if a yellow bar appears at the top asking if you want to enable content or allow
edits, click on the button provided to enable content or edits. Once you have your Excel file template
open, you should enter your edits into this file, to reflect the current year submission data.

The template contains several tabs (Figure 5-1). The first tab in the excel file is an "Information" tab.
This worksheet shows the version of your template, the date the version of the template was updated,
some general instructions, as well as a list of recent changes from a previous version. You should make
sure that you download your previous year data in the most recent version of the workbook available in
CAERS. Using a workbook from a previous year report, for example, will cause errors in upload, further
QA checks, and a potential rejection due to an incomplete submission further down the process.
Versioning of workbooks is kept at a minimum during reporting, but updates do happen. When they do,
it is recommended you upload your report with changes you have already made, and then download
your report again, in the new template, to continue reporting. This helps ensure that you have an
updated version of the template, which may prevent errors in future.

55


-------
In general, the template contains two sets of tabs:

Reference tabs are highlighted in gray. These are an Information tab, Worksheet Map and lists of codes
for entry of different data fields. Please do not attempt to edit these lists as they are part of the data
validation for the data entry tabs. The list of tabs is as follows:

•	Information Tab

•	Worksheet Map (containing JSON Keys)

•	Aircraft Engine Type Code (for airport SCCs only)

•	Calculation Material Code

•	Calculation Method Code

•	Calculation Parameter Type Code

•	Contact Type Code

•	Control Measure Code

•	Emission Factor Code

•	Emission Formula Variable Code

•	Emissions Operating Type Code

•	Facility Category Code

•	Facility Source Type Code

•	FIPS County Code

•	FIPS State Code

•	HAP Facility Category Code

•	NAICS Code

•	Operating Status Code

•	Pollutant

•	Program System Code

•	Release Point Type Code

•	Reporting Period Type Code

•	Source Classification Code

•	Tribal Code

•	Unit of Measure Code

•	Unit Type Code

Data entry tabs are highlighted in blue. Each tab contains specific types of data to be submitted. Drop-
down menus help you avoid errors when entering codes, by displaying the allowed choices. The data
entry tabs are:

•	Facility

•	Facility Contacts

•	NAICS

•	Release Points

•	Emission Units

•	Emission Processes

•	Controls

•	Control Paths

•	Control Assignments

•	Control Pollutants

56


-------
•	Apportionment

•	Reporting Period

•	Operating Details

•	Emissions

•	Emission Formula Variables

The blue data entry worksheets have the same entities that are presented in the web application, for
example: facility level data, release points, and emissions units. There are several fields that are
required in the spreadsheet so that it can be used in CAERS successfully. These fields are denoted by an
asterisk in the column header (row 10). Be sure to enter values or select an option from the dropdown
menu in each of the required fields.

There are also relationships among some of the blue data entry worksheets. For example, the "Emission
Processes" worksheet will ask for the corresponding Unit ID for each process row. The options in the
"Unit ID" dropdown menu on the "Emission Processes" worksheet are based on the units that are
available on the "Emission Units" worksheet. As new units are added on the "Emission Units"
worksheet, they will be automatically added to the "Unit ID" dropdown menu on the "Emission
Processes" worksheet. Therefore, you need to enter your emission units before they are available in the
"Emission Processes" worksheet. Other instances where fields are dependent on other worksheets
include:

•	"Control Assignments" worksheet:

o Path ID relies on entries from the "Control Paths" worksheet,
o Control ID relies on entries from the "Controls" worksheet,
o -Control Path (Child) relies on entries from the "Control Paths" worksheet

•	"Control Pollutants" worksheet: Control ID relies on entries from the "Controls" worksheet

•	"Apportionment" worksheet:

o Release Point ID relies on entries from the "Release Points" worksheet,
o Process ID relies on entries from the "Emission Processes" worksheet,
o Control Path ID relies on entries from the "Control Paths" worksheet

•	"Reporting Period" worksheet: Process ID relies on entries from the "Emission Processes"
worksheet

•	"Operating Details" worksheet: Reporting Period relies on entries from the "Reporting Periods"
worksheet

•	"Emissions" worksheet: Reporting Period relies on entries from the "Reporting Periods"
worksheet

•	"Emission Formula Variables" worksheet: Reporting Period Name relies on entries from the
"Emissions" worksheet

There is special formatting in the bulk upload template, such as hidden fields and formulas. Ensure that
you are keeping with the correct format for each data field and are using the codes as indicated by the
drop-down menus. Many fields that are required by CAERS are hidden from view in the spreadsheet to
help avoid uploading mismatched data, for example associating an emissions process to the wrong
emissions unit. Use caution when performing certain actions within the bulk upload spreadsheet. Here
are examples of potential risks:

•	Overriding formulas: Within Excel, if you copy several horizontally adjacent cells of data and
paste them into the CAERS Bulk Upload spreadsheet then you risk overwriting a necessary

57


-------
formula in a hidden field. However, you can safely copy and paste data vertically within a
column.

•	Overriding drop-down menu values: Pasting data into a field which has a drop-down menu will
allow you to enter any data; however, if the value does not precisely match one of the values in
the drop-down menu then the upload will return an error.

•	Deleting drop-down menu: Deleting a cell that has a drop-down menu can potentially delete
the drop-down menu completely. While deleting the entire cell will cause a problem, deleting
the content of the cell is not a problem. For example, if cell E24 has a value of "CAP" then you
can delete "CAP" but should not delete cell E24.

•	Overlooking changes to other worksheets: when an error is fixed in a parent cell, connected
cells do not refresh automatically. Be sure to update the connected cells even if the change
doesn't alter the connected cells. For example, when you enter a Unit ID on the "Emission
Units" tab, that value will be available as an option in the Unit ID dropdown menu on the
"Emission Processes" tab. If you navigate back to the "Emission Units" tab and change a Unit ID
then you will need to manually update all of the rows on the "Emission Processes" tab that have
the unit chosen. There may be a cascading effect with this example if the process has already
been chosen from the Process ID dropdown menu on the "Apportionment" tab. In this scenario,
you would need to update the Unit ID on the "Emission Units" tab, reselect the unit from the
Unit ID dropdown on the "Emission Processes" tab, and reselect the Process ID on the
"Apportionment" tab.

•	Skipping or clearing rows: If a row is skipped or cleared in a worksheet, the identifiers below the
cleared or skipped rows may not cascade to subsequent worksheets. For example, if a row of
data is cleared in the "Emission Units" worksheet, then the units below the cleared rows do not
always appear in the drop down for available units in the "Emissions Process" worksheet.

58


-------
Figure 5-1. Example of Bulk Upload Template Worksheet

AutoSave OfQ

Home Insert

99999999-Facilitylnc.-2020.xlsx - Last Modified: 4m ago »

Page Layout Formulas Data Review View Help Acrobat

P Search

fh*0*

nscopy -

* ^ Format Painter

B I U

' A A -

Font

BOOl-PROOl-Annual

$ - % 5

Number

Condrtionsl Format as

l£5 Share P Comments

mmm Eg*¦ zvpi

Insert Delete Format .	Find &

v Clear-	Filter - Select-

3	Enter all information marked Where a drop-down menu exists, select from the list of options in each menu. All field formats are "General" except where specified.

4	Ensure that data copied into cells is in the correct format and is devoid of spaces, quotation marks and other characters.

5	Enter all reporting period information before working on this tab.

6

7]

8 Tab: Emissions

9

to

14

15

16

24

25

Instruction:

Drop down. The unit,
process, and reporting
period reference.

Drop down. Pollutant from the process in
the reporting year.

Drop down. Select "true" if no emission
factor exists, or the units of measure of the
denominator of the available emission
factor do not match your throughput units of
measure.

Total emisisons for
the pollutant.

Drop down. Units of measure
of the emissions.

The overall perce
pollutant that is re
the controls in th
from the process 1
release point.

Field

Reporting Period*

Pollutant Name*

I prefer to calculate this emission myself

Total Emissions*

Emissions Unit of Measure*

Overall Control %

example entry

ML05-1 -Annual

Acetaldehyde

false

1000







SCR-1-Annual

Benzene

false

1007 75

TON





SCR-2-Annual

Nitrogen Oxides

true

2015 e

TON





BOOl-PROOl-Annual

»ilatile Organic Compounds

true

300

LB













26













27













28













29













30













31













32













33













34













35













36













37













38













39













40













41













42



























.

^Display Settings

5.2 Bulk Upload Steps

Once your data is ready in the bulk upload template, from the "Emissions Reports" screen (Figure
4-2) click on "Upload Report". Click on the "Browse" button to find the location of your bulk upload
workbook on your computer. Once you have found the workbook, select it and the file name will now
appear on your screen. Click the "Upload" button. A pop-up window will appear to show that the
workbook is being uploaded. The speed at which this happens will depend on your internet connectivity
speed. The upload may take several minutes depending on the size of the file.

It is good practice to give yourself extra time to address any errors that may emerge when using bulk
upload and/or the actual report content. CAERS wiii run validations checks on your Excel file before
allowing you to submit it, such as verifying that the required fields are present and that text fields do not
exceed maximum lengths. These validation checks will be different than the QA checks that will be run
on the data contents in addition, once it has been uploaded. Validation checks are run for the data file
structure and format, whereas QA checks are run on the data contained in the file.

If the uploaded spreadsheet has errors that keep it from uploading to CAERS successfully then you will
see a list of "Data Errors" on the screen. Each error will indicate the worksheet and row in error, as well
as a brief message describing the error. After all the errors have been resolved, you can attempt to
upload the file again. If there are not any errors in the uploaded spreadsheet then you will be brought
directly to the "Report Summary" for the uploaded report. At this stage you can navigate the CAER
System as described in Section 4.

59


-------
Note that there are two kinds of errors you may get with BU. The first, as described above, are upload
errors. These errors are separate from reporting errors. Once your report is uploaded, you should now
click on the "Quality Checks" (per Section 7) to ensure that you do not have data errors that need to be
addressed. Depending on how many errors you may have, it may be easier for you to just address them
in the Ul instead of attempting another upload. This is a matter of personal preference.

5.3 JSON

If you would like to upload your file in JavaScript Object Notation (JSON), you should select that option
from the drop-down menu on the "Download as Template" button. To upload the report, you will
similarly use the "Upload Report" button. For reference data, you can use the gray tabs in the BU
template, as explained in the previous section (section 5.15.1 above). If you are interested in this
option, send an email to caer@epa.gov and we will send you a schema to follow, as one is not currently
available in CAERS. A schema will eventually be available by clicking on the "Help" link from the top left-
hand side of your screen, and scrolling down to "Additional Resources", then clicking on the "JSON
Upload Schema" link.

Figure 5-2. JSON Upload Option in CAERS

ACBI Disclaimer CAERS Help Contact CDX

Emissions Reports

Continue I Download as Template ' I Delete

Upload Report ~ I Continue

Excel Download
JSON Download

6 Reporting Emissions Using Bulk Entry

If there are few to no changes in the facility inventory data, the reporter may benefit from bulk
entry. Note that to use bulk entry, facility data will have to be present in the system beforehand. If you
need to add a unit, process, release point, or controls information, refer to the sections in this guide for
reporting through the user interface. If you have many changes, you may prefer to use the bulk upload
capability. Also note, that if emission factors changed, you should re-select the emission factors from
the emissions calculation page to allow CAERS to update it. Then you can proceed to your bulk entry.

To start entering data via bulk entry, click on "Bulk Entry" from the left-hand side menu. There are two
tabs to work on for bulk entry. The first one is for "Process Information". Here, you should enter the
throughput value information that has changed since your previous year report. Click on the "Save and
Update" button at the bottom right of the tab to save your changes. See Figure 6-1.

60


-------
Note that this is the only information that can be edited from this screen. If there are changes to
throughput material, or units of measure of throughput, those changes must be made in the page for
the relevant process. You can access that process page by clicking on the process ID. This will re-direct
you to the process page. Once you have made the edits there, you can return to the bulk entry screen
and continue with your report.

Figure 6-1. Bulk Entry Process Information Tab

Agency: GA

Report Summary
Report History
Quality Checks
Data Bulk Entry <

~Facility Inventory

Facility Information
Emissions Units
Release Points
Control Devices
Control Paths

~Emissions
Inventory

~	FlA

~	FIB

~	PI01

~	VP01

~	VP02

~	VP02A

Data Bulk Entry

Process Information

Emission Information

Unit

Process

Throughput





Previously Reported Throughput

% Change in

ID

ID

Material

Throughput Value



Value

Throughput

PI01

NOX

Wood Waste

123.56

E3TO

123.56 E3TON

0.000

©







N





VP01

NOX1

Item

315435

E6BT

315435 E6BTU

0.000

0





U





VP02

VOC1

Paper

357918

TON

357918 TON

0.000

0











VP04

PSS

Natural Gas

137771

E6BT

137771E6BTU

0.000

o





U





Save and Update

The second page for Bulk Entry is the "Emissions Information" tab, which you can click on from the
"Process Information" tab after entering your throughput data. Enter the total emissions if they have
changed since your previously reported emissions. Click on the "Save and Update" button at the bottom
right of the tab to save your changes. Again, in this tab, note that any changes to the calculation
method, or units of measure must be entered in the relevant pollutant page. To go to that page, click on
the pollutant and this will re-direct you to the relevant page. See Figure 6-2.

61


-------
Figure 6-2. Bulk Entry Emissions Information Tab

Agency: GA

Report Summary
Report History
Quality Checks
Data Bulk Entry <

'•Facility Inventory

Facility Information
Emissions Units
Release Points
Control Devices
Control Paths

~Emissions
Inventory

~	F1A

~	FIB

~	PI01

~	VP01

~	VP02

~	VP02A

Data Bulk Entry

Process Information

Emission Information















Previously

% Change

Unit

Process





Emission





Reported Total

in

ID

ID

Pollutant

Calculation Method

Factor

Total Emissions



Emissions

Emissions





Nitrogen

Continuous Emission Monitoring



72.10

TO

72.107 TON

0.000





Oxides

System



N





PI01
©

NOX ©

Sulfur Dioxide

Continuous Emission Monitoring
System



12.78

TO
N

12.781 TON

0.000





Volatile

Stack Test (no Control Efficiency



100

TO

5.5151 TON

1713.204





Organic

used)



N









Compounds

















Nitrogen

Continuous Emission Monitoring



16.99

TO

16.996 TON

0.000





Oxides

System



N





\/oni

wrv/1

Sulfur Dioxide

Continuous Emission Monitoring



0.100

TO

0.1005 TON

0.000

Save and Update

7 Performing Quality Checks

When you have finished entering or uploading your data, the next step is to run the quality checks.
Before doing so, please consult the checklist in Appendix D of this user guide. When you are ready to
perform the quality checks, click on "Report Summary" on the left-hand side menu of your screen to go
to the Report Summary page. Click on the "Run Quality Checks" button below the "Report Summary"
table. This will take you to a "Quality Review" page where you will see two types of errors listed (Figure
7-1):

•	Critical errors will appear in red. These errors must be addressed for the report to go through.

•	Warnings will appear in purple. These errors will not prevent you from submitting the report,
but they will alert you to potential issues you may want to address before submitting.

Broadly speaking, error messages fit in one of the following categories:

•	Calculation errors - Data calculated outside the form that doesn't match up with what
the CAERS is calculating, for example:

o Your reported emissions for a process and pollutant are not within 1% (warning)
or 5% (critical) of the emissions CAERS is calculating.

•	Inconsistent data entries - Data entered is not possible given some physical or temporal
constraint, for example:

o 100% of annual emissions for 52 weeks of operation have been entered as

occurring during the Winter season;
o The latitude for a release point has been reported but is too far from the facility

(outside of its facility latitude threshold);
o An emission factor was provided, but its denominator is in different units of

measure than throughput, so a simple conversion is not possible; and
o The reported emissions previous year reported emissions are identical to the
previous inventory year reported emissions.

62


-------
•	Expected information is missing - Data are expected to be entered, but the data field is
empty. This includes data fields that are conditional on the entry of others. Examples
include:

o In the EPA emission factor, the" I prefer to calculate the total emissions of this
pollutant" has been checked but the "Description of Calculation" box has not
been populated;
o Controls exist that have not been assigned to a path; and

o If a release point stack diameter is reported, then exit gas flow rate and exit gas
velocity should also be reported.

•	Incorrect format - Data must be entered in a specific format, for example:

o Postal code must be in five-digit or nine-digit format; and
o Value for a year must be four digits.

•	Data is not allowed - Data entered is not allowed, for example:

o Duplicate ID was entered for the same component (unit, release point, process,
or control), but ID's for sub-facility components must be unique within the
facility;

o Units of measure that are not supported are being used; and
o SCC entered has been retired in a year prior to the inventory year being
reported.

In the case of data that are not allowed, some legacy data may have been carried into the CAER System.
While the old data will be displayed, the system may require you to update it. For example, in a
previous submission you used a unit of measure code "Million BTUS", but the system now requires you
to enter the new code "E6BTU". Be sure to update the information by selecting a valid code from the
drop-down list.

Figure 7-1. Quality Review Page

Report Facility & Emissions Information	Perform Quality Checks	Submit to SL.T Authority	Approved by SLT Authority

ajiflCY 1012345671

f ACUITY INC	#

Report Summary

Report History
Quality Checks <
~Facility Inventory

Fac -ty Information
Emissions Units

Control Devices
Control Piths
"Emissions Inventory

t FIB

~	PK>1

~	VPOI

~	VP02

~	VP02A
» VP02Q

~	VP02C

~	VP02D

~	VP02E

Errors

1	Em ssion Unit '/PW. Emission Process: PSS. Pclutant: Nitrogen Oxides - Total emissions cannot oe calcijiatec with the given emissions factor because Throughput UoM MILLION BTUS cannot
beconverted to Emission Factor Denominator UoM MILLION CUBIC FEET PSease adjust Units of Measure or choose the option "i prefer to calculate the total emissions of this pollutant"

2	Emission Unit VP04 Em'ssion Process PSS. Polutant: Carbon Monoxide - Total emissions cannot be calculated with the given emissions factor because Throughput UoM MILLION BTUS cannot
be converted to Emission Factor Denominator UoM MILLION CUBIC FEET Please adjust Units of Measure or choose the option "i prefer to osculate the total emissions of this polutant."

3.	Envision Unit VP04 Em'ssion Process. PSS. Pollutant: Su fur pipode • Total emiss-ons cannot be calcu steti with the given emissions factor because Throughput UoM MILLION BTUS cannot be
converted to Emission Factor Denominator UoM MILLION CUBIC FEET. Please adjust Units of Measure or choose the option 'I prefer to calculate the totai emissions of thispol: utant"

4.	Emission Unit VP04 Emission Process PSS. Pc lutant Vo -ati e Organic Compounds - Total emissions cannot be calculated with the given emissions factor because Throughput UoM MILLION
BTUS cannot be converted to Emission Factor Denominator UoM MILLION CUBIC FEET. Please adjust Units of Measure or choose the option "I prefer to calculate the totai emissions of this
pollutant*

3. Emission Unit VPOI. Envssion Process NQX1. Polutant: Volatile Orgaric Compounds • Total emissions cannot be calculated with the given envssions factor because Throughput UoM MILLION
BTUS cannot be converted to Emission Factor Denominator UoM MILLION CUBIC FEET. Please adjust Units of Measure or choose the option "I prefer to calculate the total emissions of this
pollutant'

4 Emission Unit VPOI. Emission Process NOX1 - The total apportionment for alI re ease points associated with this process must equa-' 100%

7	Emission Unit VPOI. Emission Process NOX1 • The release point SV03 is reported more than once for the same release point apportionment collection

8	Emission Unit FiA. Emiss-on Process Mace up process - The total apportionment for al s release points associated with this process must ecua 1005%

9. Envssion Unit FIA Emission Process Mace uo process - The emissions process is not associated with a release point A process must go to at least one release point

10. Emissions lin t: F IB - Emission Unit Design Capacity must be between 0.01 and lOO.OCO.OOO.

11 Release Pomt: 5V04 • Release Point latitude must be within me 0.0035 tolerance range of Facility latitude coordinate 33.660270.

12.	Release Point SV04 • Release Point longitude must be within the 0.0035 tolerance range of Facility longitude coordinate -83.933850.

13.	Release Point: SV01 - Release Point latitude must oe within the 0.0035 tolerance range of Facility latitude coordinate 33.660270.

14 Release Point: SVQ1 - Re'ease Point longitude must be within the 0.0035 tolerance range of Facility longitude coordinate -83 938S90.

Note: Example errors here are riot comprehensive in this figure.

63


-------
To address each error on the quality review page, click on the name of the error (underlined), to be
taken to the screen where the error is occurring (Figure 7-2). You will see a red bar at the top of your
screen containing the error to be addressed. Click on the "Edit" button of the relevant box to make your
edits, then click "Save". You can now click on the "x" at the top right of the error message in the red box
to remove it from view.

Figure 7-2. Correcting an Error

Report Facility & Emissions Information

Perform Quality Checks

Submit to SLT Authority

Approved by SLT Authority

1. Total emissions cannot be calculated with the given emissions factor because Throughput UoM MILLION BTUS cannot be converted to Emission Factor Denominator UoM
MILLION CUBIC FEET. Please adjust Units of Measure or choose the option "I prefer to calculate the total emissions of this pollutant"

Process Information

Unit ID:

VP04









Process ID

PSS

Reporting Period:

Annual

Operating Status:

Operating

Calculation Material:

Natural Gas

Calculation Value:

137771

Calculation UoM:

MILLION BTUS

Calculation Parameter

Input









Emission Information

Pollutant:
Pollutant Name:

Nitrogen Oxides • NOX
Nitrogen Oxides

Pollutant Code:
CAS ID:

Calculation Method:
Emission Factor:

Emission Factor
Numerator UoM:

Overall Control %;
Total Emissions:

USEFA Emission Factor (no Control Efficierv
100

Emissions Factor
Description:

~ Emission Factor

Denominator UoM:

Emissions UoM:

TON

I prefer to calculate the total emission:

of this pollutant

Click on "Quality Checks" link on the left-hand side of your screen to return to the "Quality Review"
page. When you return to the "Quality Review" screen the error will have disappeared. Once you have
finished correcting your errors you should re-run the quality checks. Once you have addressed all errors
you will see the "Quality Review" screen devoid of error messages (Figure 7-3). Note that warnings may
still appear. You will also see the blue line has advanced on the top of your screen to show that the
quality checks step has been completed.

64


-------
Figure 7-3. Completing Quality Checks

Agency ID: 999S9999

Report Summary

Report Facility & Emissic

Perform Quality Checks

Approved by SLT Authority
	•

Quality checks were completed successfully with no warnings or

Quality Review

rs. You can now certify and submit your report from the Report Summan

Quality Checks <
Report Creation Log
Data Bulk Entry
•Facility Inventory
Facility Information

'Emissions Inventory

ressibility Notice | Privacy and Security Notice

8 Certifying and Submitting to your State, Local, or Tribal (SLT)
Authority

As an NEI Certifier, you will log into CAERS and chose the "certifier" role from the "My CDX" page
(Figure 3-14). You will see the same screens as the preparer. However, when you are in the "Report
Summary" page, you will see an additional button "Certify and Submit to SLT". When you are ready to
certify that your submission is complete and accurate, click on that button.

You will see a window stating that you can download and review a copy of your report as in Figure 8-1,
indicating the date and time since the last time the report was updated. The current copy of record is in
Excel (Windows). The window also shows links to instructions for you to download free versions of the
software for viewing in Windows or Mac.

If in a final review of your report, you find an error, please correct it before certifying and submitting, to
avoid delaying your submission further (see Section 8.2 for instructions on how to correct a report after
it has been certified).

65


-------
Figure 8-1. Submission Review Screen

I

"lissic

1

Submission Review

Facility Name:

-lissic Facility ID:

Report Year:

Emissions Report Last Updated:

Facility Inc.

99999999
2021

March 30,2022 at 9:15:16 PM GMT-4

Before submitting your report, you should download a copy and review it for accuracy.

Download Report Excel File

Download Report Attachments

•	Attachment 999999 My Facilftyxlsx

If you do not have Microsoft Excel installed on your computer you can open and view the report using the following
alternative applications:

•	XL5X Viewer Free I7ul if you are working in Windows OS.

•	Numbers	if you are working in Mac OS.

~ I acknowledge that I have had the opportunity to download and review the data in this report.

None

Noi>
0

Proceed I Cancel

ole

Comments

8.1 Certification and Submission of Report

If you are satisfied with the report, you can click "Proceed". This will take you to a three-stage
(CROMERR) process. First, it will request your password, then it will ask you to answer a security
question. Finally, it will ask you to click certify and verify you are submitting correct information (Figure
8-2). You will see a "please wait" sign while you are waiting. Once the submission has been certified, a
message will appear in green at the top right of your screen. The progress bar at the top of your screen
will have changed and "Submit to SLT Authority" will now be highlighted in blue.

Figure 8-2. Submission Certification

^lame

Preparer/NEI Certifier Attachm

I certify under penalty of lav/ that I have personally
examined and am familiar with the information I
submitted in this and all attached documents, and
that based on my inquiry of those individuals
immediately responsible for obtaining the
information, I believe that the submitted information
is true, accurate, and complete. I am aware that
there are significant penalties for submitting false
information, including the possibility of fine and
imprisonment.

Accept I Decline

66


-------
Once you have submitted your report, you will also be able to click the "Report" button on the "to
obtain a summary report for your records.

8.2	Correcting Reports with Errors

Once your report has been certified and submitted to your SLT, it will be locked and in "view only"
mode. You will receive an email from the system notifying you that your report has been successfully
submitted. You will now only be able edit the report if your SLT pushes it back to you. This may happen
if your SLT has found errors and would like you to correct them. If so, you will receive an email with an
explanation of what the SLT would like you to change.

However, if you have already certified your report and realize it contains an error, you should
reach out to your SLT immediately, and have them reject the report and push it back to you so you may
edit the report. The POC information for your SLT can be found by clicking on the "Help" tab, and is also
listed in this document in Section 11.2.

8.3	Disputing or Repudiating a Report

In the unlikely event that you receive an email notifying you that your report has been submitted

but:

•	You did not perform this submission,

•	You have any reason to dispute or repudiate this submission,

•	You determine there is a discrepancy between the electronic document you signed and
submitted, and the record received by CDX,

then please reach out to the Help Desk immediately, and within the first 24 hours of realizing there is an
issue with your report so that the relevant action may be taken promptly. The email notification from
the original submission will contain instructions for how to proceed as well as the Help Desk
information. Please do not reach out to your SLT first for this issue, as this will only delay solving the
problem further. If you do, your SLT will have to direct you back to the Help Desk to start the
repudiation process. Your Help Desk staff will take the necessary steps to address the matter. The Help
Desk information can also be found in the Help tab at the top right of your screen, and in Section 11.1 of
this document.

8.4	CDX Submission History

You can obtain copies of record for your submissions by going to the CDX "Submission History"
page. From your MyCDX screen (Figure 3-14), at the top of your screen you will see the "Submission
History" tab. By clicking on that tab, you will find your submission history. See

67


-------
Figure 8-3. CDX Submission History Page

S-EPA

Home About Recent Announcements Terms and Conditions FAQ Help

CDX; Central Data Exchange

I MyCDX I i Inbox j My Profile

Logged in as JUUAGAMAS fLoo out)

Submission History

Recent Submissions

Your most recent submissions are displayed below. You can perform Custom Submission Search to view more
submissions.

9 items found, displaying all items.
Submission id i

dae8be6a-3464-
45e8-9996-
b3795a6fa25e

41bld212-d562-
435f-ade9-

Combined Air
Emissions
Reporting
Submission

Combined Air

Emissions

Reporting

Download

Link f.zipl

4ab61a39-80ed-
4312-91a0-
9a6bfel6977d

CAER

Combined Air
Emissions
Reporting
Submission

Mar 31, 2021
2:02:45 PM

Link (.zip)

7f54b307-1869-
4134-8b56-
ee0b5fc22649

CAER

Combined Air
Emissions
Reporting
Submission

Mar 23, 2021
3:53:09 PM

Link f.zip)

e4a6c5aa-a8f9-
de3cl2c967e6

CAER

Combined Air
Emissions
Reporting
Submission

Jan 6, 2021
1:54:05 PM

Link (.zip)

b5e4b2fa-f94e-
40cc-bd61-
eefd97c9d269

CAER

Combined Air
Emissions
Reporting
Submission

Jan 6, 2021
1:43:33 PM

Link (.ziDl

cb697a54-fced-
49a6-a988-
C011a2c76760

CAER

Combined Air
Emissions
Reporting
Submission

Jan 6, 2021
1:35:15 PM

Link f.ziDl

22f52454-al03-
4134-bf62-
91236fce8bl9

CAER

Combined Air
Emissions
Reporting
Submission

Jan 6, 2021
1:27:57 PM

Link (.zip)

9	Submission Approval

Once the report has been submitted, your SLT Authority will review the report. The person listed as
preparer, certifier, and the "Emissions Inventory" contact for your facility, will be notified of whether the
report was approved or rejected.

Once your SLT has reviewed your report, it will then send that report to EPA. While every effort has
been made to provide preparers with quality assurance checks that will help you submit the highest
quality data, both your SLT staff and EPA's Emissions Inventory System (EIS) may present additional
checks (either new, or checks that are not possible to include in CAERS given their nature). These checks
may require you to make corrections to your report after you have certified it. In that case your SLT will
return your report for revisions. These revisions usually take place in the Fall. To avoid some of these
issues, we encourage you to review the "Additional Considerations" sections after each section and
chapter.

If rejected, comments in the email will explain the issue(s) to be addressed. At that point you
should re-open your report and issue the corrections indicated by your SLT Authority. If your preparer
or certifier contact person will change at any time after the report was submitted, please let staff at
your SLT know so the new contact person can be approved to enter CAERS and issue any corrections as
needed.

10	Using Data Reported in CAERS for a TRI-MEweb submission

If you are an NEI-TRI facility reporter, you may start a TRI and NEI reportable chemical Reporting
Year (RY) 2020 Form R in TRI-MEweb at anytime before the July 1 TRI reporting deadline. You must have

68


-------
submited and certified your CAERS data before you start your TRI Form R in the TRI-MEweb application
to use the API web service call to populate CAERS data into Section 5.1 and 5.2. You should follow these
steps to use data reported to CAERS in TRI-MEweb to save time reporting to both systems.

Note that currently in CAERS, for your data to be usable in TRI, you must have a one to one match
between your NEI and TRI facility, and pollutant. Your emissions types should also match: in your
emissions inventory report you typically enter an emission operating type " routine", and can also enter
shutdown, startup and upset. Your TRI report also includes a category of non-routine (catastrophic
events not associated with normal or routine production processes which can apply to air emissions
releases) in Form R, Section 8.8. You must ensure that your routine emissions in your annual inventory
report in NEI matches your routine emissions in TRI

1. Upon arriving to Section 5 of the RY 2020 TRI Form R, an an application to application

(Application Programming Interface or API) call between CAERS and TRI-MEweb will verify if
your EPA Facility Registration ID and CAS number match any data point in the CAERS database.
Data in the CAERS database must be certified for it to be used in TRI-MEweb. See Figure 10-1.

Figure 10-1. Example of Section 5 Form R Screen in TRI-MEweb

EI

& Ott sil* IfSfttflllS *

1: Oil-Mid UVaslo MsriAtyaimant

On-site Releases and Disposal

Form R Part II. Section 5 © Need Reporting Help?

Hovw your cuisct ovei II'o © Icon lot imva irili* mutton f-iitei date iinlKQ iM."

Form Section

Air Retaasas

Section 51 Fugitive or NorvPowt Air Enrofore ©

Section 52 Slack or Poont Ah Emissions ©

I acid Releases

Section i 4 1 On-site UruJagiound tajedlon Clmt I Walls ©

Sectkm 5 4 2 On-site Underground Ireealan Class ll-V V-'alls Q
Section 551A On-ste Landfllls RCRA Subtitle C ©

Section 5510 On Ms Landfills Oltwr ©

Sectkm 5 52 On-site land Treatment andAppfccation Famwtg ©
Sedlon553A On-ateSwtece Impoundments RCRASuMMeC©

Section 55 JO On-s«eSurface Impoundments Other©

Settle* 554 Other On-Sits Disposal ©

A facifcy that manages waste rock piles may ele
-------
Figure 10-2. Example of "NEI Data Available" Screen

EU

My TR)	Mefiageniei* - Nino- SuMnonHHoq Hep

Pint IV 3/4: AntMrtn* anil UsasIMsi On «IW 5. On *ll» Rnfeawui v

6; Off *Wa Tnin«f«r* v 7: On-*»« W

hi Mnnagarnem v 9; Misc. infejmKMion

On-site Releases and Disposal

Fomi R. Part II. Section 5 Q Need Reporting Help?

TFXPAR nAiNBRIOGr TrRMIWll ni7l7TXPRM>WllN

Saefon $ I Fiiglbvo or MocvAjim Ar FmtsslMW Q
5-sctton 52 Steele or Pcfct'fr Efrtssons Q

Laid lielHM)

Soc6w>5J1 Qtt-sfteUm!etsiuu>dltxet4an.CS»s»llftells0
SscBur 5 4.2 On-afce UiOeiyrotiiiJ Itfec&vi Oass fl-V Welfc ©
iecUonOivawUndiHb. ncHASuwmeCO
section s 5.16: Oivsts LamlHBs Oln« Q
Sadlwi $ 52 On-sf» Laro Trwiinent and AtClcalion Fjrmng O
Sactkin 5 5 3A Otvste SlrtK* lironi.ndmfnts RCRA SutsKs C Q
^selkw6fi.TR QihASurfacelirjxwmdmeTli; OthatQ
^etitwf.5 4 Oth« On-Silc Oispixil Q

A fablity dial irunagw «aaa rock pfiat m
8 Select Ihc checkboa 2 ;ou wsiulifBke to

Tntai Quantity (fat) Q

Sdcd a Range Ccds -
Safer* a Rargn Crate •

¦	s Range C
-------
collected in Section 9.1 of the TRI Form R. We would like to make the submission process easier
for you, and we appreciate knowing how we can improve this process for you.

Figure 10-4. Example Pop-Up Window for Comment

»»

Sw.t»N Si 4 Qtliti Or-:

_n aatr.I a Range Cooe

ne cf tbcguflnlhcs oftrcd jfcnc fcn Se

6. If you select "Yes, copy my CY [year] NEI emission data into Section 5.1 and 5.2", the quantities
will be copied into the TRI form R. You will then need to complete Form R, validate, and certify
to complete their TRI reporting requirement.

11 Where to Go for Help

You can get help and more resources by clicking on the "CAERS Help" tab on the top right side of your
screen (see Figure 11-1).

71


-------
Figure 11-1. Help Screen in CAERS

Help Resources

Application Support

The Combined Air Emissions Reporting User Guide and Glossary will provide instructions and terminology necessary to navigate through the application from registration to report submission.

•	Combined Air Emissions Reporting User Guide Version 3.2

•	Combined Air Emissions Reporting Glossary

CAERS Helpdesk Support

The CDX Helpdesk Support is also your CAERS Helpdesk Support.

Please contact the CDX Helpdesk by using one of the options listed at https://cdx.epa.gov/Contact.

Program Support

Note: Questions relating specifically to emissions reporting and facility data should be directed to your SLT Authority.

•	Georgia Department of Natural Resources (GADNR): Emissions.lnventory@dnr.ga.gov. (470) 524-0723

•	Pima. AZ Department of Environmental Quality (PDEQ): Janice Easley. Janice.easley@pima.gov, (520) 724-7451

•	Rhode Island Department of Environmental Management (RIDEM): Alexi.Mangili@dem.ri.gov. (401) 222-2808 ext. 2777019

•	Washington. D.C. Department of Energy & Environment (DOEE): air.quality@dc.gov. (202) 535-2600

Additional Resources

•	Default Fuel Heat Content for Energy Conversions

•	TRI-NEI Pollutant Crosswalk - email caer@epa.gov for a copy of the crosswalk.

•	Data Collection Authority

EPA Home | MyCDX | Accessibility Notice | Privacy and Security Notice

I'l.l Help with the CAERS application itself.

Reach out to the help desk for questions about how to enter data into CAERS: You can find that
help by clicking on the "Contact CDX" link at the top right of your screen at any time while you are in the
User Interface.

Questions for the CDX help desk include the following types of issues:

•	Questions about logging into your CDX account

•	Unexplained errors while using the application

•	How to enter a specific piece of data

•	How to navigate from one screen to another

Note that the help desk above is not the right resource for questions about the data itself. Those
questions should be referred to your SLT Authority.

11,2 Help with programmatic questions:

Reach out to your SLT for questions related to the content of your submission, such as:

•	Critical errors will appear in red. These errors must be addressed for the report to go through.

•	Selecting an appropriate SCC and/or emission factor

•	Finding out the unit capacity measure of a unit

•	The appropriateness of a specific type of conversion for a specific kind of process:

Points of contact from your SLT are:

Georgia Department of Natural Resources (GADNR): Emissions. Inventory (Sdnr.ga.gov
Pima, AZ Department of Environmental Quality (PDEQ): Janice Easley, Janice.easlev@pima.gov
Rhode Island Department of Environmental Management (RIDEM): Alexi.MangiiiPdem.ri.gov
Washington, DC Department of Energy & Environment (DOEE): air.qualitv(5)dc.gov

72


-------
Please do not contact EPA directly, or EPA contractors for any questions, or this will only delay getting
you help further. Please reach out to the CDX help desk (registration, and CAERS application-related) or
your SLT first (programmatic). This will ensure the right help gets to you as quickly as possible.

73


-------
Appendix A Understanding Controls

The U.S. EPA is moving to a new way of representing controls in the National Emissions Inventory
(NEI). In this section, we introduce the new concepts regarding controls to help you understand how to
set the controls up for your facility in the CAERS.

It is important to capture the overall control reduction percentage for a given Process-Release Point-
Pollutant combination, and thus, capture emissions totals correctly.

In the previous control device requirements for the NEI, we were not able to:

•	Describe how controls are configured at a facility

•	Define the relationship among Controls and Units, Processes, and / or Release Points

•	Reuse the Definition a Control in the data, so that the same Control Equipment can be used by
many components (Units, Processes, and Release Points)

•	Change the values of controls data fields easily

The new way of setting up controls for emissions reporting will include the following features:

•	A list of controls can exist for the facility as those controls exist in the real world.

•	A control will only define one single piece of control equipment.

•	Only the pollutants impacted by this piece of equipment will be listed with the control.

•	The percent reduction for the pollutant will be the amount of emissions reduced due to this one
piece of equipment.

•	The "path" of can be described with the data:

o In series
o In parallel

There will be three new items to track in the new controls approach that are worth explaining. A few
examples are included to illustrate the application of the concepts:

1.	Control Path: defined as one or more controls at a facility that are linked. The path will allow
the user to define multiple kinds of control setups. A path can consist of controls or other
"children" paths. A path cannot refer to itself (or another path that contains it). Ultimately,
there should be a "main path" that will define the controls that are encountered from the
emissions generation point to the release point. That is, there should ultimately be at least one
master path between a unit and a release point. These concepts will become clearer in the
examples to follow.

2.	Control Apportionment: defined as the percentage of the emissions that flows to the next
control or path. For example, if emissions coming out of one control flow into one other control
in a series, then the control apportionment is 100%. If emissions from one control flow to two
or more other controls or paths, then the combined apportionment of those emissions to the
other controls or paths must be equal to 100%. For example, 60% of emissions move from
control 1 to control 2, and 40% of emissions flow from control 1 to control 3.

3.	Control Assignment: defines the sequence or order in which controls are configured within a
path. The first control in a path would have sequence number 1, the second control would have
sequence number 2, and so forth. If there is a path within the path, that path will also have a
sequence number.

A-l


-------
A. 1	Example of a Facility with No Controls

A facility that has no controls does not need to create any paths. All the user must do is provide a
release point apportionment for the process(es) that send emissions to one or more release points.
Figure A. 1 shows a graphic example of a facility with no controls. The red arrow represents emissions
that ultimately move from the process to the release point: in this case all Process 1 emissions go to
Stack 1. Table A. 1 shows how the data would be entered into the CAERS (or the bulk upload template)
for the facility absent any controls. In this example, emissions from Process 1 are sent to Stack 1, so
Stack 1 is apportioned 100% of Process 1 emissions.

Figure A. 1. Example of a Facility with No Controls

Table A. 1. Example Associations for a Facility with No Controls

Unit ID

Process ID



Path ID

Release Point
ID

Release Point
Apportionment

Boiler 1

Process 1





Stack 1

100%

If the process emits to more than one release point, then the relevant percentage of emissions
ultimately moving from Process 1 to each release point would need apportionment percentages. For
example, assume that Process 1 emissions ultimately go to all three stacks with 50% going to Stack 1,
25% of its emissions going to Stack 2 and 25% going to Stack 3. In this case, the release point
apportionments would be as shown in Table A. 2.

A-2


-------
Table A. 2. Example Associations with No Controls

Unit ID

Process ID



Path ID

Release Point
ID

Release Point
Apportionment

Boiler 1

Process 1





Stack 1

50%

Boiler 1

Process 1





Stack 2

25%

Boiler 1

Process 1





Stack 3

25%

A. 2	Example of a Facility with a Single Control

Figure A. 2 shows the example of a facility with a single control. The yellow arrow indicates
emission moving from the process to the control device. The red arrow shows the emissions moving to
the release point. In this scenario, assume there is one process, Process 1. The Control 1 is placed in
Path 1. The control apportionment is 100% and the control assignment sequence number is 1. Error! R
eference source not found, shows the assignment of the control. Table A. 4 shows the associations for
that control and the other relevant sub-facility components.

Figure A. 2. Example of a Facility with a Single Control

all

/ U U U a

; Path 1



l-f.'If-TU '





Table A. 3. Example Path Data for a Facility with a Single Control

Path ID

Sequence Number

Control or Child Path
Assignment

Apportionment
(for Control or Path)

Path 1

1

Control Device 1

100%

A-3


-------
Table A. 4. Example Associations for a Facility with a Single Control

Unit ID

Process ID

Path ID

Release Point ID

Release Point
Apportionment

Boiler 1

Process 1

Path 1

Stack 2

100%

A. 3	Example of a Facility with Controls in Series

In Figure A. 3 we can see an example of a facility that has controls in series. Assume there is one
process per unit, Process 1 and Process 2 for Boiler 1 and Boiler 2 respectively. In this case, there are
three controls. Controls 2 and 3 have been placed in Path 1. Path 2 contains Control Device 1 and Path
1. Path 1 is a child path of Path 2.

You should configure your controls into paths is a matter of how your controls are laid out in the facility
from the units to the release points. There should ultimately be one master path between a unit and a
release point. In this case, that master path is Path 2. If more than one process is being run from the
unit, then all the processes would be associated with the control path in the same manner as Process 1.

Figure A. 3. Example of a Facility with Controls in Series

For this example, we can see in Figure A. 4 that the controls are in series. The emissions flow directly
from one control to the other. Thus, the control apportionment for Control 1 to Path 1 is 100%, and the
control apportionment for each control within Path 1 is 100%. In Path 1, Control 2 is first in the
sequence, Control 3 is second. In Path 2, Control 1 is first in the sequence, Path 1 is second in the
sequence, and, and Scrubber 1 is third. Table A. 5 shows the assignment for this facility. Table A. 6
shows the associations for the different sub-facility components. Also, note that all emissions enter
Stack 1 after leaving Path 2 (as indicated by the red arrow). Finally, 100% of emissions from Process 1
went to Stack 1, and 100% of emissions from Process 2 also went to Stack 1.

A-4


-------
Figure A. 4. Path Assignments for a Facility with Controls in Series

Path 2

Table A. 5. Example Path Data for a Facility with Controls in Series

Path ID

Sequence Number

Control or Child Path
Assignment

Apportionment
(for Control or Path)

Path 1

1

Control Device 2 (C2)

100%

Path 1

2

Control Device 3 (C3)

100%

Path 1

3

Scrubber 1 (SI)

100%

Path 2

1

Control Device 1 (CI)

100%

Path 2

2

Path 1

100%

Table A. 6. Example Associations for a Facility with Controls in Series

Unit ID

Process ID

Path ID

Release Point ID

Release Point
Apportionment

Boiler 1

Process 1

Path 1

Stack 1

100%

Boiler 2

Process 2

Path 2

Stack 1

100%

A. 4	Example of a Facility with Complex Controls

Figure A. 5 represents a more complex controls set up. Again, we show just one process for the
unit, but all processes associated with that unit (if shown) would be treated in the same way as Process
1. This controls setup is a combination of controls in series and parallel. Path 1 contains Control 2 and
Control 4. Path 2 contains Control 1, Control 3, and Path 1 (child path), and Control 5. Path 3 contains
Path 2 (child path), and Scrubber 1.

A-5


-------
Figure A. 5. Example of Complex Controls

Figure A. 6. shows the different assignments and apportionments given this set up. in Path 1, Control 2
is first in the sequence, Control 4 is second, and 100% of emissions flow from Control 2 to Control 4, and
100% of the emissions flow to Control 5 from Path 1. Path 1 is a child path of Path 2. In Path 2, Control

1	sends 60% of its emissions to Path 1 (where Control 2 is first in the sequence), and 40% of its emissions
go on to Control 3. Then 100% of emissions go from Control 3 to Control 5, 100% of emissions exit Path

2	(via Control 5) to Path 3. In Path 3, Path 2 (child path) is first in the sequence, then the Scrubber is
second in the sequence. Assignments are shown in Table A. 7. How the different sub-facility
components are associated is shown in Table A. 8. Note that 50% of emissions from Process 1 go to
Stack 1, and 50% of emissions from Process 1 went to Stack 3 (as indicated by the red arrows in Figure A.
5).

A-6


-------
Figure A. 6. Path Assignment for a Facility with Complex Controls

Path 3

L

Table A. 7. Example Path Data for a Facility with Complex Controls

Path ID

Sequence Number

Control or Child Path
Assignment

Apportionment
(for Control or Path)

Path 1

1

Control Device 2 (C2)

100%

Path 1

2

Control Device 4 (C4)

100%

Path 2

1

Control Device 1 (CI)

100%

Path 2

2

Control Device 3 (C3)

40%

Path 2

2

Path 1

60%

Path 2

3

Control Device 5 (C5)

100%

Path 3

1

Path 2

100%

Path 3

2

Scrubber 1 (SI)

100%

Table A. 8. Example Associations for a Facility with Complex Controls

Unit ID

Process ID

Path ID

Release Point ID

Release Point
Apportionment

Boiler 2

Process 1

Path 2

Stack 3

50%

Boiler 2

Process 1

Path 3

Stack 1

50%

A-7


-------
A. 5	Additional Examples of Control and Path Assignments

Example 1: Planer Mill Cyclofilter (single control)

Figure A. 7 shows an example of a single control where a Planer Mill Cyclofilter is used. In this
case there is only one control and it should be placed in one path. All processes (planer and planer trim
block hog) should be associated with that path and the corresponding release point. Table A. 9 and
Table A. 10 show path and association data respectively.

Figure A. 7. Planer Mill Cyclofilter Path Assignment

Table A. 9. Path Data for Planer Mill Cyclofilter

Path ID

Sequence Number

Control or Child Path
Assignment

Assigned Control or
Child Path
Apportionment

Path 1

1

Planer Mill Cyclofilter

100%

Table A. 10. Associations for Planer Mill Cyclofilter

Unit ID

Process ID

Path ID

Release Point ID

Release Point
Apportionment

Planer

Process 1

Path 1

Stack 1

100%

Planer Trim Block Hog

Process 2

Path 1

Stack 1

100%

A-8


-------
Example 2: Controls Working Alternately Example

In this example, emissions go from a loading rack to a vapor combustor unit (VCU) or a vapor
recovery unit (VRU), but not to both. There are VOC emissions from the VRU. When the VRU is used,
the emissions go to a stack. The VCU works when the VRU is not working. The VCU is a backup to the
VRU, and in this example, assume it only works 1% of the time. However, when each one of these
controls is working, it takes in 100% of the emissions. When the VCU is operating, the emissions are
flared. The VCU uses propane, so its emissions are VOC as well as NOX and CO. See Figure A. 8

Figure A. 8. Example for Controls Working Alternately

Tanks

Liquid
return

Propane

In this case, while the vapors could go to either the VRU or the VCU, because of the use of propane in
the VCU, we effectively have two different processes with two different SCCs (Figure A. 9).

Furthermore, each process is going to a different release point. Specific information about the number
of hours each component is working would be entered in with the process information. For example,
the number of hours that each is run. Note that because in this case the original process has been
divided in two processes to run through each of the two control devices, effectiveness for each would be
100% and you would enter the hours that each control runs. Table A. 11 and Table A. 12 show path and
association data respectively.

A-9


-------
Figure A. 9. Path Assignment for Controls Working Alternately

Process 2

Propane

VOC, NOXand CO

Table A. 11. Path Data for Controls Working Alternately

Path ID

Sequence Number

Control or Child Path
Assignment

Assigned Control or
Child Path
Apportionment

Path 1

1

VRU

100%

Path 2

1

VCU

100%

Table A. 12. Associations for Controls Working Alternately

Unit ID

Process ID

Path ID

Release Point ID

Release Point
Apportionment

Unit 1

Process 1

Path 1

Release Point 1

100%



Process 2

Path 2

Release Point 2

100%

A, 6	Example of Controls Calculations

The following example may help you understand how the different percentages involved in
controls calculations are related. This example may help you estimate your "Overall Control %" for your
individual control and/or control path. The example is illustrative, you should work with your SLT
authority to determine the best way to do these calculations for your specific control device
configuration.

The following definitions are used in this example:

Percent Capture Efficiency: The percentage of an exhaust gas stream that is actually collected for
routing to a set of control devices. This value could be obtained from the vendor or measured at the
facility. The capture is equivalent to the release point apportionment.

Percent Control Effectiveness: The percentage of time or activity throughput that a control approach is
operating as designed, including the capture and reduction devices. This percentage accounts for the

VCU





Release point 2

1

1

1

Path 2

A-10


-------
fact that controls typically are not 100 percent effective because of equipment downtime, upsets and
decreases in control efficiencies. This could be estimated from the amount of time the control is
operational, versus down for maintenance or repairs.

Percent Reduction Efficiency: The percent reduction achieved for the pollutant when all control
measures are operating as designed. This could be obtained from the vendor.

Assume you have a control or control path for Particulate Matter with the following:

•	capture efficiency (cap) is 90%,

•	control effectiveness (effect) is 80%,

•	control efficiency (effic) is 95%, and

•	uncontrolled (unc) or pre-control emissions total 100 tons.

Figure A. 10. Flow of Uncontrolled Emissions

% Efficient

Process

Uncontrolled Emissions

Then:

Total uncontrolled emissions = captured emissions + fugitive (non-captured emissions) = [unc x cap] +
[unc x (1-cap)].

Captured emissions= emissions when control is not effective + emissions when control is effective = [unc
x cap x (1-effect)] + [unc x cap x (effect)]

Emissions when control is effective = emissions reduced from control efficiency (controlled emissions) +
emissions from control inefficiency = [unc x cap (effect) x effic] +[ unc x cap x (effect) x (1-effic)]

Stack emissions = emissions when control is not effective + emissions from effective control inefficiency
= [unc x cap x (1-effect)] + [unc x cap x effect x (1-effic)] = unc x cap [(1-effect) + effect x (1-effic)] = unc x
cap (1-effect + effect x effic) = unc x cap x (1-effect x effic)

Fugitive emissions = 100 x (1-0.9) = 10

A-ll


-------
Stack emissions = 100 x 0.9 x (1-0.8 x 0.95) = 21.6

Controlled emissions = unc x cap x effect x effic = 100 x 0.9 x 0.8 x 0.95 = 68.4

Total emissions = Controlled emissions + Stack emissions + Fugitive emissions = 68.4 + 21.6 + 10 = 100

A-12


-------
Appendix B Types of Fugitive Release Points

EPA is moving to have more detailed representations of fugitive emissions. While in the past data
has only been entered using the "Fugitive - Area" format, there are now two new ways that you can
enter your fugitive emissions data, in addition to the current form of representation. When you choose
the format you will use, you will only need to enter data required by that format. Below are the three
types of fugitives for the reporter to select.

1. Fugitive - Area

This is the current format for entering fugitive release point data. The reporter is asked to enter:

1.	Fugitive "Area" Release Point

•	Width

•	Length

•	Height

•	Latitude from South West corner of the facility blueprint

•	Longitude from South West corner Longitude

•	Angle of Measure

Figure B. 1. Graphical Representation of Current "Area" Fugitive Release Points

2. 2-Dimensional Fugitive Release Points

This is an updated version of a Fugitive "Area" representation as described above. Examples of 2-
Dimensional release points include: a single elongated roof (horizontal) vent, opening, or window,
typically greater than or equal to 10 square feet, or a wastewater holding pond for building fugitives,
typically greater than 10 square feet. Data fields to be reported for this type of release point are:

•	Height

•	Width

•	Two Sets of Coordinates (Latitude/Longitude of the Midpoints of Opposing Sides of Source).
These should be within a default tolerance of 0.003, from the facility latitude and longitude. If
you feel your fugitive coordinates should be allowed beyond the default tolerance, please
contact your SLT as soon as possible.

o Coordinate 1 Latitude
o Coordinate 1 Longitude
o Coordinate 2 Latitude

Fugitive Angle

Coordinates from
SW Corner

Release Point Length

Release Point Width

B-l


-------
o Coordinate 2 Longitude
Figure B. 2. Graphical Representation of 2-Dimensional Fugitive Release Points

3. Graphical Representation of 3-Dimensional Fugitive Release Points

Unlike two-dimensional release points that emit only at a specific height, the emissions from three-
dimensional release points are emitted across the entire height of the release point. Typically, a single
vertical window should be reported as a "low flow vent" type of release point, unless there are multiple
windows of that nature in which case the 3D fugitive type is more appropriate.

Examples of this type of release point include: an entire building with multiple release point on walls
and/or roof where each release point could not be easily identified by using many low flow vent
releases, and an outdoor storage pile. The assumption is that the base of the release point is square.
While the shape of a storage pile, for example, is unlikely to be a shape with a square base, reporters
should simply set the width and length so that the horizontal dimension represents or encompasses, as
best as possible, the actual shape and set the height to represent the height span of the release. If the
release is not a square shape, the length and width must be set as best as possible to represent the
actual shape of the source, since width and length are required to be the same.

Figure B. 3. Graphical Representation of 3-Dimensional Fugitive Release Points

Release Point
Fugitive Height

Release Point Width

\

Coordinates Represent
Center of Footprint

Data fields to be reported for this type of release point are:



Height

• Width

Latitude of the footprint center
Longitude of the footprint center

Additional Considerations: Dimensions for height, width, length, as the case may be, are expected to
be greater than 0. Also, latitude and longitude values are expected to be within a 0.003 tolerance of the

B-2


-------
facility latitude and longitude coordinates. If you feel that the release point coordinates for your facility
should be allowed beyond that default tolerance, please get in touch with your SLT as soon as possible.

B-3


-------
Appendix C Additional Resources

C, 1	Heat Content for Energy Conversions

The following is a list of default heat content values for energy conversions for a variety of fuels.
You should reach out to your SLT to determine the best approach for your specific fuel type and fuel use,
as these default values may not be appropriate for you to use under your specific circumstances.

Table C. 1. Default Heat Values for Fuels

Fuel Name

Default High

Units of Measure

Source



Heat Value





Anthracite

25.09

Million BTU/ShortTon

GHGRP

Anthracite Culm

11.513

Million BTU/ShortTon

EIAA5

Bagasse At 50% moisture

4000

BTU/Pound

AP42 AA

Bark At 50% moisture

4,500

BTU/Pound

AP42 AA

Bituminous Coal

24.93

Million BTU/ShortTon

GHGRP

Bituminous/Subbituminous Coal

17.25

Million BTU/ShortTon

GHGRP

Butane

0.103

Million BTU/Gallon

GHGRP

Coal

19.292

Million BTU/ShortTon

EIAA5

Coal Mixed (Commercial sector)

21.39

Million BTU/ShortTon

GHGRP

Coal Mixed (Industrial coking)

26.28

Million BTU/ShortTon

GHGRP

Coal Mixed (Industrial sector)

22.35

Million BTU/ShortTon

GHGRP

Coal Mixed (Electric Power sector)

19.73

Million BTU/ShortTon

GHGRP

Coke

24.8

Million BTU/ShortTon

EIAA5

Coke Mixed (Commercial sector)

21.39

Million BTU/ShortTon

GHGRP

Coke Mixed (Industrial coking)

26.28

Million BTU/ShortTon

GHGRP

Coke Mixed (Industrial sector)

22.35

Million BTU/ShortTon

GHGRP

Coke Mixed (Electric Power sector)

19.73

Million BTU/ShortTon

GHGRP

Coke Petroleum Coke

30

Million BTU/ShortTon

GHGRP

Coke Oven Gas

590

BTU/Dry Standard Cubic Feet

AP42 AA

Crude Oil

0.138

Million BTU/Gallon

GHGRP

Digester Gas

0.619

Million Btu/Thousand Cubic Feet

EIARNW

Distillate Oil Average

5.771

Million BTU/Barrel

EIAA3

Distillate Oil 15ppm sulfur and under

5.7

Million BTU/Barrel

EIAA1

Distillate Oil > 15 ppm to 500 ppm sulfur

5.817

Million BTU/Barrel

EIAA1

Distillate Oil >500 ppm sulfur

5.825

Million BTU/Barrel

EIAA1



C-l






-------
Fuel Name

Default High

Units of Measure

Source



Heat Value







Distillate Oil Diesel

137381

Btu/Gallon

EIA CC

Distillate Oil No. 1

0.139

M

llion BTU/Gallon

GHGRP

Distillate Oil No. 2

0.138

M

llion BTU/Gallon

GHGRP

Distillate Oil No. 4

0.146

M

llion BTU/Gallon

GHGRP

Gas Blast Furnace Gas

0.092 x 10-3

M

llion BTU/Dry Standard Cubic Feet

GHGRP

Gas Coke Oven Gas

0.599 x 10-3

M

llion BTU/Dry Standard Cubic Feet

GHGRP

Gas Fuel Gas 4

1.388 x 10-3

M

llion BTU/Dry Standard Cubic Feet

GHGRP

Gas Other Biomass Gases

0.655 x 10-3

M

llion BTU/Dry Standard Cubic Feet

GHGRP

Gasoline

5.222

M

llion BTU/Barrel

EIA A1

Gasoline Natural Gasoline

0.11

M

llion BTU/Gallon

GHGRP

Gasoline Motor Gasoline

0.125

M

llion BTU/Gallon

GHGRP

Gasoline Aviation Gasoline

0.12

M

llion BTU/Gallon

GHGRP

Kerosene-Type Jet Fuel

0.135

M

llion BTU/Gallon

GHGRP

Kerosene-Type Jet Fuel

5.67

M

llion BTU/Barrel

EIAA1

Special Naphtha

0.125

M

llion BTU/Gallon

GHGRP

Naphtha Type Jet Fuel

5.355

M

llion BTU/Gallon

EIAA1

Kerosene

0.135

M

llion BTU/Gallon

GHGRP

Landfill Gas

0.485 x 10-3

M

llion BTU/Dry Standard Cubic Feet

GHGRP

Lignite

14.21

M

llion BTU/Short Ton

GHGRP

Liquid Waste Rendered Animal Fat

0.125

M

llion BTU/Gallon

GHGRP

Liquid Waste Vegetable Oil

0.12

Million BTU/Gallon

GHGRP

Liquid Waste Ethanol

0.084

Million BTU/Gallon

GHGRP

Liquid Waste Biodiesel (100%)

0.128

M

llion BTU/Gallon

GHGRP

Liquid Waste Black Liquor

11.758

M

llion Btu/ShortTon

EIARNW

Liquid Waste Waste Alcohol

3.800

M

llion Btu/Barrel

EIARNW

Liquified Petroleum Gas (LPG)

0.092

M

llion BTU/Gallon

GHGRP

Natural Gas (Weighted U.S. Average)

1.026 x 10-3

M

llion BTU/Dry Standard Cubic Feet

GHGRP

Natural Gas Methane

0.841

M

llion Btu/Thousand Cubic Feet

EIARNW

Propane Gas

2.516 x 10-3

Million BTU/Dry Standard Cubic Feet

GHGRP

Natural Gas Liquids Ethane 1

0.068

M

llion BTU/Gallon

GHGRP

Natural Gas Liquids Isobutane 1

0.099

M

llion BTU/Gallon

GHGRP

Natural Gas Liquids Natural Gasoline

0.11

M

llion BTU/Gallon



Oil Used Oil

0.138

M

llion BTU/Gallon

GHGRP

Oil Unfinished Oils

0.139

M

llion BTU/Gallon

GHGRP

C-2


-------
Fuel Name

Default High

Units of Measure

Source



Heat Value







Oil Heavy Gas Oils

0.148

M

llion BTU/Gallon

GHGRP

Oil Lubricants

0.144

M

llion BTU/Gallon

GHGRP

Oil Asphalt and Road Oil

0.158

M

llion BTU/Gallon

GHGRP

Petroleum Liquid Other Oil (>401 deg F)

0.139

M

llion BTU/Gallon

GHGRP

Petroleum Liquid Pentanes Plus

0.11

M

llion BTU/Gallon

GHGRP

Petroleum Liquid Petrochemical Feedstocks

0.125

M

llion BTU/Gallon

GHGRP

Petroleum Liquid Butylene 1

0.105

M

llion BTU/Gallon

GHGRP

Petroleum Liquid Ethylene 2

0.058

M

llion BTU/Gallon

GHGRP

Petroleum Liquid Isobutylene 1

0.103

M

llion BTU/Gallon

GHGRP

Petroleum Liquid Still Gas

0.143

M

llion BTU/Gallon

GHGRP

Naphtha (<401 deg F)

0.125

M

llion BTU/Gallon

GHGRP

Propylene

0.091

M

llion BTU/Gallon

GHGRP

Blast Furnace Gas

0.092 x 10-3

M

llion BTU/Dry Standard Cubic Feet

GHGRP

Process Gas

0.599 x 10-3

M

llion BTU/Dry Standard Cubic Feet

GHGRP

Landfill Gas

0.485 x 10-3

M

llion BTU/Dry Standard Cubic Feet

GHGRP

Methane

0.841

M

llion BTU/Thousand Cubic Feet

EIARNW

Propane

0.091

M

llion BTU/Gallon

GHGRP

Residual Oil No. 5

0.14

M

llion BTU/Gallon

GHGRP

Residual Oil No. 6

0.15

M

llion BTU/Gallon

GHGRP

Sludge Waste

7.512

M

llion BTU/Short Ton

EIA RNW

Sludge Wood

10.071

M

llion BTU/Short Ton

EIA RNW

Solid Waste Municipal Solid Waste

9.95 3

M

llion BTU/Short Ton

GHGRP

Solid Waste Agricultural Byproducts

8.25

M

llion BTU/Short Ton

GHGRP

Solid Waste Peat

8

M

llion BTU/Short Ton

GHGRP

Solid Waste Solid Byproducts

10.39

M

llion BTU/Short Ton

GHGRP

Solid Waste Tires

28

M

llion BTU/Short Ton

GHGRP

Solid Waste Plastics

38

M

llion BTU/Short Ton

GHGRP

Solid Waste Agricultural Byproducts

8.248

M

llion BTU/Short Ton

EIARNW

Solid Waste MSW Biogenic

9.696

M

llion BTU/Short Ton

EIARNW

Solid Waste Paper Pellets

13.029

M

llion BTU/Short Ton

EIARNW

Solid Waste Railroad Ties

12.618

M

llion BTU/Short Ton

EIARNW

Solid Waste Solid Byproducts

25.830

M

llion BTU/Short Ton

EIARNW

Solid Waste Spent Sulfite Liquor

12.720

M

llion BTU/Short Ton

EIA RNW

Solid Waste Utility Poles

12.500

M

llion BTU/Short Ton

EIA RNW

Subbituminous

17.25

M

llion BTU/Short Ton

GHGRP

Wood and Wood Residuals (dry basis)

17.48

M

llion BTU/Short Ton

GHGRP

C-3


-------
Energy Conversion Sources:

•	EIA CC: https://www.eia.gov/energyexplained/units-and-calculators/energy-conversion-
calculators.php

•	EIA A1-A5: https://www.eia.gOv/totalenergy/data/monthly/#appendices

•	EIA RNW: https://www.eia.gov/renewable/annual/trends/pdf/tablel_10.pdf

•	GHGRP: Table C-l to Subpart C of part 98'; https://www.epa.gov/sites/production/files/2015-
06/documents/ghg-mrr-finalrule.pdf

•	AP42 AA: https://www3.epa.gov/ttnchiel/ap42/appendix/appa.pdf

C, 2	Unit Conversions in the CAER System

The following is a list of simple conversions that the CAER system can perform on units of
measure to the level of detail (decimal values) that the form is performing them:

Table C. 2. List of Simple Unit of Measure Conversions in CAERS

Type of
conversion:

Amount

to
convert
from:

Units to convert
from:

Amount to convert to (application
conversion):

Units to
convert to:

Area

1

ACRES

43560

SQUARE FEET

Area

1

SQUARE YARDS

9

SQUARE FEET

Area

1

ACRES

4840

SQUARE
YARDS

Length

1

MILES

5280

FEET

Mass

1

KILOGRAMS

1000

GRAMS

Mass

1

POUNDS

0.45359237

KILOGRAMS

Mass

1

GRAMS

0.000001

MEGAGRAMS

Mass

1

KILOGRAMS

.001

MEGAGRAMS

Mass

1

POUNDS

.00045359237

MEGAGRAMS

Mass

1

GRAMS

1000000

MICROGRAMS

Mass

1

KILOGRAMS

1000000000

MICROGRAMS

Mass

1

POUNDS

453592370

MICROGRAMS

Mass

1

MEGAGRAMS

1E+12

MICROGRAMS

Mass

1

MILLIGRAMS

1000

MICROGRAMS

Mass

1

NANOGRAMS

0.001

MICROGRAMS

Mass

1

TONS

907,184,740,000

MICROGRAMS

Mass

1

GRAMS

1000

MILLIGRAMS

Mass

1

KILOGRAMS

1000000

MILLIGRAMS

Mass

1

POUNDS

453592.37

MILLIGRAMS

Mass

1

MEGAGRAMS

1000000000

MILLIGRAMS

Mass

1

GRAMS

1000000000

NANOGRAMS

Mass

1

KILOGRAMS

1E+12

NANOGRAMS

Mass

1

POUNDS

453592370000

NANOGRAMS

Mass

1

MEGAGRAMS

1E+15

NANOGRAMS

Mass

1

MILLIGRAMS

1000000

NANOGRAMS

C-4


-------
Type of
conversion:

Amount

to
convert
from:

Units to convert
from:

Amount to convert to (application
conversion):

Units to
convert to:

Mass

1

GRAMS

.0022046226218488

POUNDS

Mass

1

TONS

2000

POUNDS

Mass

1

GRAMS

.000001102311310924388

TONS

Mass

1

KILOGRAMS

.0011023113109244

TONS

Mass

1

MEGAGRAMS

1.102311310924388

TONS

Mass

1

MILLIGRAMS

.000000001102311310924388

TONS

Mass

1

NANOGRAMS

.000000000000001102311310924388

TONS

Volume

1

DRY STANDARD
CUBIC FEET

.028316846592

DRY

STANDARD

CUBIC

METERS

Volume

1

GALLONS

.00378541178

DRY

STANDARD

CUBIC

METERS

Volume

1

DRY STANDARD
CUBIC FEET

.037037037037037

CUBIC YARDS

Volume

1

GALLONS

.004951131682011

CUBIC YARDS

Volume

1

CUBIC METERS

1.307950619314392

CUBIC YARDS

Volume

1

DRY STANDARD
CUBIC FEET

7.480519488424055

GALLONS

C. 3	Volume Conversions for Natural Gas

Volumetric conversions of natural gas depend on the physical conditions of the natural gas as

follows.

To convert the volume of natural gas below 60 psia:

Under these conditions the Ideal Gas Law can be applied. Subscript 1 indicates gas at one set of
conditions of absolute temperature (T) in degrees Rankine (°R), and absolute pressure (P) in pounds per
square inch absolute (psia), subscript 2 indicates the same gas at a different set of conditions for the gas.

VI = Tl/Pl (P2 V2/T2), to get VI in cubic feet (cf).

A dry standard cubic foot (scf) of gas is defined as a cubic foot at a temperature of 21 °C (70 °F or 530 °R)
and a pressure of 101.325 kilopascals [kPa] (14.696 psia), except for liquefied petroleum gas.

Therefore, if converting from a gas with volume V2 at standard cubic feet of gas to VI, the formula to
apply would be:

V1=T1/P1 (14.696 x V2)/530

To convert the volume of natural gas above 60 psia:

C-5


-------
Natural gas does not behave like an ideal gas in this case. The formula requires a compressibility factor
(Z).

V1=V2(Z1 T1 P2)/(Z2 T2 PI), to get VI in cf,
where Z1/Z2 is the compressibility ratio.

For example: If converting from a gas with volume V2 at 60 °F (or 520 °R) and 14.73 psia to another
volume, the formula would be:

V1=V2(Z1 x T1 x 14.73)/(Z2 x 520 x PI),

Sources:

Paul R. Ludtke, Natural Gas Handbook, National Bureau of Standards, U.S. Department of Commerce,
Boulder, CO, August 1986. p 14.

NIST, Uniform Laws and Regulations in the Areas of Legal Metrology and Engine Fuel Quality (2017 ed.).
National Institute of Standards and Technology (NIST). November 2016. p. 120.
doi:10.6028/NIST.HB. 130-2017. Retrieved 21 November 2017.

C. 4	State Emission Factor Compendium

If your SLT Authority allows it, you may use emission factors available from other states. To
browse the Emission Factor Compendium, go to the CAER website and look under the "Development of
a State-Local-Tribal Emission Factors Compendium". You will find three spreadsheets (from Minnesota,
Michigan and South Carolina), that may contain an emission factor your SLT deems appropriate for you
to use.

The current version of CAERS (V3) will be upgraded later in 2022 to allow facility reporters to
select an SLT factor from the compendium when selecting "SLT Emission Factor" from the calculation
method list when estimating emissions.

C-6


-------
Appendix D CAERS Submission Checklist

While CAERS is equipped with a number of QA checks designed to prevent you from sending
incorrect data to EPA and your SLT, there are still some checks that CAERS cannot run. It is in your best
interest to check this list to remove as many issues as possible that may delay your submission, and/or
cause your report to be rejected by EPA's Emissions Inventory System if it finds additional errors. EPA
reserves the right to send a report back to your SLT even if all these steps have been taken, if additional
issues that are not listed here, appear in your report.

Before Entering CAERS	

Make sure you're registered and have an account with CDX as preparer or certifier.

Make sure you remember your password or have allowed time for password changes every
90 days.

Before Starting a Report or Downloading the Bulk Upload Template	

Your facility is listed in "My Facilities" page, or you have requested access to your facility.
You have gone into the User Interface and have checked that your facility information is
correct before certifying the report, and have reached out to the SLT to help with corrections
only the SLT can make.

You have run the QA checks in the User Interface to see any new QA checks that need to be
addressed in your report.

You have made any edits or corrections in the Ul that you would prefer to do there, to have
them appear in your Bulk Upload template.

If your facility did not report last year, your operating status is set to "Operating", and that
status year is not in conflict with a previously reported status year. E.g. you have not
reported your facility as "TS" in 2019, but are now reporting it as "Operating" also in 2019.

While Creating a Report	

	 Bulk Upload Template	

You have not deleted entire rows in the template.

You have not replaced entire rows in the template.

You have not attempted to enter component IDs in columns where you must select them
from the drop-down menu.

	All Reporting Methods	

You have not deleted a component (e.g. unit, control) that existed in a previous report. You

	must report it or mark it as "PS" or "TS".	

You have not simply re-labeled a component, as you must keep the original ID, or mark as
"PS" a component you want to re-label, then you must recreate it.

You have not created a brand new component and then marked it as "TS" or "PS". Any new
components must be operating.

For any components you have marked "PS" or "TS" you have also provided an "operating
status year" that is greater than the last year you reported the component as operating. E.g.
you cannot report that an item was operating in 2020 in a previous report, and then say it was

	"PS" in this year's (2020) report.	

For any process you have marked as "PS" or "TS" you have also provided an operating status
year that is consistent with the operating status of its unit. E.g. you cannot have an operating
process in 2019 if the unit was "TS" in 2019 unless it is a landfill.

You have not marked as "PS" or "TS" a component for the same year when that component
operated and had emissions and is reporting emissions. E.g. if a unit operated only 3 days in a
year, it is still considered "Operating" for that year.

D-l


-------


You have put all controls in their respective paths, and have no empty paths.



You have cleared all critical quality checks.

D-2


-------
Appendix E Monthly Reporting for DOEE Facilities

This section only applies to facilities reporting to DOEE as their SLT, Starting 2022, facility
reporters wiii be able to enter fuel data on a monthly basis. To do so, you should look for the "Monthly
Fuel Reporting" link on the left hand side of your screen (Figure E. 1).

Figure E, 1. Monthly Fuel Reporting Link for DOEE Facilities

Report Summary <
Report History

TyChecks"
Monthly Fuel Reporting

ata Bulk Entry
^Facility Inventory

Facility Information
Emissions Units
Release Points
Control Devices
Control Paths

'Emissions Inventory

~	005

~	006

~	Bethune

~	Blackburn

~	Burr Gymnasium

~	Cook

~	CU-1

~	CU-18

Pollutant	Tyf

Ammonia	CA

Carbon Dioxide	GH

Carbon Monoxide	CA

Lead	CA

Nitrogen Oxides	CA

PM Condensible	CA

PM10 Filterable	CA

PM10 Primary (Filt + Cond)	CA

PM2.5 Filterable	CA

PM2.5 Primary (Filt + Cond)	CA

Sulfur Dioxide	CA

Volatile Organic Compounds	CA

Total Emissions (Tons)	—

When you click on that link, you will be taken to a separate set of screens where you can see, at the top,
a tab for each month of the year (Figure E. 2). To report fuel for a specific process, that process must
already have been created in CAERS. If you have reported to DOEE in previous years, the list of
previously reported processes will be prepopulated for you. To this list you should add any data that
may be missing for new processes that operated that inventory year. You should not attempt to start
reporting monthly fuel for the inventory year 2022 until after you have completed your 2021 inventory
year report, as processes cannot be created for a future year in CAERS at this time.

E-l


-------
Figure E. 2. Monthly Fuel Reporting Screens for DOEE Facilities

Report Summary













Report History

January

February

March

April May

June

Semi-Annual Review

Quality Checks

July

August

September

October November

December

Annual Review

Monthly Fuel Reporting <

Unit ID

Process ID SCC

Fuel Material

Total Fuel Value



Total Operating Days

Data Bulk Entry

Blackburn

0

1^_ ^ 10200502









"Facility Inventory













Facility Information
Emissions Units
Release Points
Control Devices
Control Paths

"Emissions Inventory

CU-21

o

CU-22

o

From Figure E. 2, we can see that in this example, the facility has no fuel material reported. The
reporter would click on the process ID to be taken to that process page (refer to section 4.3.2) and enter
the fuel material there. Then the fuel material will appear on the monthly reporting screen (see Figure
E. 3). Note that many SCCs have a single fuel allowed to be reported. While future versions of CAERS
may prepopulate this fuel for you, as of now, the reporter must enter it.

Figure E. 3. Monthly Fuel Reporting with Fuel Material Listed

Report Summary
Report History
Quality Checks
Monthly Fuel Reporting <
Data Bulk Entry
"Facility Inventory
Facility Information
Emissions Units
Release Points
Control Devices
Control Paths

"Emissions Inventory

January
July

February
August

March
September

April	May

October	November

Unit ID

Blackburn

CU-21
©

CU-22
©

rocessID SCC



June	Semi-Annual Review

December	Annual Review

Total Operating Days

10200502 V Distillate Oil
10300602
10300602

Enter amount of fuel used in the "Total Fuel Value" column, as well as the total operating days that
month (Figure E. 4). Click "Save Monthly Data".

Figure E. 4, Example of a Monthly Fuel Report

Agency: DOEE

Report Summary
Report History
Quality Checks
Monthly Fuel Reporting <
Data Bulk Entry
"Facility Inventory
Facility Information
Emissions Unite
Release Points
Control Devices
Control Paths

"Emissions Inventory

January
July

February
August

March
September

Unit ID

Blackburn
0

CU-19
©

CU-21

0

CU-22

0

Process ID	SCC	Fuel Material

1	10200502	Distillate Oil

1	10300602	Natural Gas

1	10300602	Natural Gas

1	10300602	Natural Gas

Monthly Data Reporting

April
October

Total Fuel Value

May
November

June
December

Save Monthly Data

Semi-Annual Review
Annual Review

Total Operating Days

Once you have entered data from January to June for the year, you will be able to submit your Semi-
Annual fuel report. Note that for 2021 inventory year, you will not be submitting that report, but
instead, will be entering monthly data for 2021. Please note that if the process operated at all during
the year, then it is considered as "Operating". Any process that did not operate at ail during the

E-2


-------
inventory year can be marked as "Permanently" or "Temporarily" shut down, as the case may be.
However, this should be done at the beginning of reporting (before certifying) or so long as you have
reported zero fuel use throughout the year. Once you have submitted a Semi-Annual Report, and/or
once you have reported any emissions for a process, you will not be able to mark that process as shut
down nor edit previous process or fuel data entered unless the SLT has pushed back your report. If you
find an error in your semiannual submission after you have certified and submitted it, you should reach
out to your SLT to have them reject your report so you may edit it.

E-3


-------