0 EDA United States	^u1Sm u 0fficeof

Environmental Protection Agency	Research and Development

National Human Exposure Assessment Survey

(NHEXAS)

Arizona Study

Quality Systems and Implementation Plan
for Human Exposure Assessment

The University of Arizona
Tucson, Arizona 85721

Cooperative Agreement CR 821560

Standard Operating Procedure	SOP-UA-L-9.1

Title: Filter Weighing
Source: The University of Arizona

U.S. Environmental Protection Agency
Office of Research and Development
Human Exposure & Atmospheric Sciences Division
Human Exposure Research Branch

Notice: The U.S. Environmental Protection Agency (EPA), through its Office of Research and Development (ORD), partially funded
and collaborated in the research described here. This protocol is part of the Quality Systems Implementation Plan (QSIP)
that was reviewed by the EPA and approved for use in this demonstration/scoping study. Mention of trade names or
commercial products does not constitute endorsement or recommendation by EPA for use.


-------
SOP# UA-L-9.1
Revision #1
15 May., 1999
Page: 1 of 20

Filter Weighing

1.0 Purpose and Applicability

The purpose of this SOP is to describe the procedures to be followed in determining the pre-
and post-weighing of 37mm and 25mm teflon filters, teflon sentinel filters and teflon vacuum
dust filters. This procedure applies to the pre- and post-weighing of the filters and samples
for the EPA NHEXAS and EPA Border projects of the University of Arizona/Battelle/Illinois
Institute of Technology consortia, as well as future "Health in the Environment"
investigations.

2.0 Definitions

2.1	Control weight= A metallic object of determined and constant weight that is
periodically re-weighed during filter weighing operations to monitor the precision of
the balance.

2.2	Deionizing unit= Radioactive Polonium-210 alpha particle source used to generate air
ions for neutralizing static charges on a filter or other object prior to weighing.

2.3	Field blank = Filter placed in impactor in the field that has no air drawn through it by a
sampling pump.

2.4	Lab blank = Randomly selected filter of a batch that is weighed and then retained in
the weighing room, to be re-weighed when the complete batch of filters returns from
the field.

2.5	M3 = cubic meter

2.6	|j.g = microgram

2.7	|im = micrometer

2.8	mg = milligram

2.9	mm = millimeter

2.10	PM = Particulate matter

2.11	SOP = Standard Operating Procedure

3.0 References

3.1	Turner, William. Manual for the Indoor Sampler (Draft dated 10/7/85). Section 3.4.4.
Harvard School of Public Health, Boston, MA 1985.

3.2	ApppnHiv F in Quality Assurance Manual for Air Quality Assessment. Harvard
University Six-City Air Pollution Health Effects Study. 1986. Volume II, Sections 3.2
and 3.3.

3.3	Mettler Toledo BalanceLink (V2.0) Software. Operating Instructions. Mettler
Instrument Corporation, Hightstown NJ, 1994.


-------
SOP# UA-L-9.1
Revision #1
15 May., 1999
Page: 2 of 20

4.0 Discussion

Net sample weight determinations are made by weighing conditioned filters prior to sampling,
and then conditioning and re-weighing the filters after they are returned from the sampling
site. The difference between pre-weight and post-weight represents the weight of the material
collected during the sampling procedure.

5.0 Responsibilities

5.1	The Project Director will be responsible for:

5.1.1 Final review and approval of this procedure.

5.2	The Project Lab Supervisor will be responsible for:

5.2.1	Insuring SOP procedures are followed by the Project Lab Staff.

5.2.2	Notifying the appropriate technicians with needed repairs. In cases when the item
can not be fixed in-house, Project Field Coordinator will generate the appropriate
paperwork, notify the appropriate vendor or company, and ship the disfunctional
item.

5.3	The Project Lab Staff will be responsible for:

5.3.1	Knowing and following the procedures described in this SOP.

5.3.2	Recording the information as directed in this SOP.

5.3.3	Notifying the Project Lab Supervisor with down equipment and repair supplies

needed (where applicable).

5.3.4	Providing the Project Lab Supervisor with down equipment label and isolating the

down equipment into the down equipment area.

5.3.5	Insuring proper labeling techniques of down equipment.

5.3.6	Repairing the item (where applicable) in a timely manner.

6.0 Equipment and Materials

6.1 Equipment

6.1.1	Class "S" calibration weight, 20 mg (#9800008)

6.1.2	Class "S" calibration weight, 100 mg (#9800007)

6.1.3	Deionizing units with Po2i0 to dissipate static electricity

6.1.4	Hydrothermograph

6.1.5	Filter trays (12" x 18")

6.1.6	Mettler AE 163 (UA ID# A195535) Balance

6.1.7	Mettler AE 166 (UA ID# A201335) Balance

6.1.8	Millipore plastic petrislide filter dish with cover, 47 mm

6.1.9	Plastic cable tie

6.1.10	Plastic 30 dram vial

6.1.11	Teflon coated forceps


-------
SOP# UA-L-9.1
Revision #1
15 May., 1999
Page: 3 of 20

6.1.12	Teflo filters, 25mm and 37mm, with 2.0 \im pore size

6.1.13	Teflon sentinel filter sheets, with 2.0 |-im pore size

6.1.14	Teflon vacuum dust filter sheets, with 2.0 \im pore size

6.2 Materials

6.2.1. Deionized distilled water (DDW)

7.0 Procedure

7.1 Preparation

7.1.1.	Weighing Area

A.	Clean the weighing area with paper towels and deionized distilled water.

B.	Locate teflon coated forceps and standard weights.

C.	Prepare the balance as outlined in "Calibration and Operation of the Mettler

Balance" (UA-L-1.1).

D.	Turn on the computer and type "cd\balance" to go to the "balance" sub-directory.

E.	Once in the Balance subdirectory, type "Balink Numeric Stable Right" to start
the program and setup the balance (UA-L-1.1; 7.2.3.A-C).

7.1.2.	Computer File Set up

A.	Computer files are created in the tracking system as they are received. A file
consist often sample ID numbers with a field for the balance weights in a database
file (UA-D-28.0).

B.	The files are created and stored in the "G:\Filters" subdirectory with the following
format "mm/dd/yffc.dbf, where; "mm" is the month, "dd" is the day, "y" is the last
digit of the year (i.e. 6 for 1996), "ff* is the sample prefix, "c" is a alphanumeric
counter (i.e. A,B,C,...) for multiple files created on the same day, and "dbf' is the

dbase program suffix.

C.	The tracking system (UA-D-28.0 ) prompts during the logging in procedure, pre-
field and post-field, for the creation of the computer datafile. Type "y" for yes and
follow the file naming convention listed above.

D.	Seperate filters into groups of five and scan into the tracking system using the light
pen. After each five filters enter one of the two class S calibration weight ID
numbers (#9800007, #9800008) which is appropriate for the general weight of the
filter class. For example, 27mm filters generally weigh -20 mg thus #9800008, the

20 mg weight, ID number is entered.

E.	After the tenth filter press escape to back out of the program which saves the file
to "G:\Filters", a subdirectory restricted to input by lab personnel only. Mark the
file name on the filter weighing backup forms (figure 1-5,7).

7.2. 25mm and 37mm Teflo Filters

7.2.1 Conditioning 25mm and 37mm Teflo Filters


-------
SOP# UA-L-9.1
Revision #1
15 May., 1999
Page: 4 of 20

A.	Conditioning consists of acclimatizing filters to standard temperature, and humidity
conditions prior to weighing.

B.	Arrange clean (UA-L-5.1) 47mm plastic petrislide filter dishes with 25mm or
37mm filters on a tray in groups of ten. Loosen the top of each petrislide to
expose the filter to ambient conditions.

C.	Check to see that a sample ID label is placed upon each plastic filter dish. Record
the date and time on the "25mm and 37mm Teflo Filter Pre-Weighing Form"

(figure 1). Place the form with the filters during conditioning. Ensure that the
computer file with the sample ID numbers has been created in the tracking system
(7.1.2. A-E) and is marked on each form.

D.	The weighing-room must remain at standard weighing conditions for temperature,
75 °± 5 °F, and humidity 50 ± 10% as outlined in the "Weighing Room Operation
and Maintenance" SOP (UA-L-2.1).

E.	Store the tray in the weigh-room conditioning locker for at least 48 hours prior to
weighing.

7.2.2 Pre-Weighing 25mm and 37mm Teflo Filters

A.	Take a batch of 10 pre-conditioned filters from the weigh-room conditioning
locker. Check that the equilibration start date and time on the batch is at least 48
hours prior to the current date and time.

B.	Set-up and calibrate the Mettler balance (UA-L-1.1).

C.	Turn on the computer, log in, and follow the computer-balance set-up (UA-L-1.1;
7.2.3.A-C).

D.	Record the pre-weigh date, room temperature, relative humidity and technicians
initials on the filter weighing form (Figure 1).

E.	Re-zero the balance for weighing by momentarily depressing the control bar.

F.	Remove a filter from it's Petrislide dish using teflon coated forceps. Pass the filter

over a deionizing unit.

G.	Check balance to read "0.00000 g" with the doors closed (re-zero if necessary),
then open a side door and place filter onto the filter support in the middle of the
balance pan.

H.	Close the door and observe the illuminated stability indicator dot.

I.	Wait five to ten seconds after stability indicator dot goes out, and depress the hand
switch transferring the weight to the computer screen. Follow the instructions on
recording weights with the computer 7.5.1.A-I.

J. Record the weight onto the "filter weighing backup form". Slight changes in the
scales environment may cause slight variations in the display. All recorded values
are valid if they reflect the value at the time that the stability light went out and
was recorded on the computer.

K. Return the filter to its petrislide dish.

L. Close the balance access doors and allow the display to return to zero. If the


-------
SOP# UA-L-9.1
Revision #1
15 May., 1999
Page: 5 of 20

display does not return to 0.00000, this may indicate zero-drift. Re-zero the
display and weigh the filter again following steps G through L.

M Repeat steps G through L for each filter.

N. Return pre-weighed filters to the lab supervisor for QC and QA checks.
7.2.3. Post-Weigh 25mm and 37mm Teflo Filter

A Upon assignment to the lab after field sampling, open the petrislide dish tops and
place onto a tray for post-conditioning. Record the sample ID#'s along with the
date and time on the "25mm and 37mm Post Weighing Form" (figure 2.0). Create
a computer file with the sample ID numbers is created within the tracking system
(UA-D-28.0).

B.	Place the "25mm and 37mm Post Weighing Form" (figure 2.0) with the filters and
place into the weigh-room conditioning locker. Ensure that the weighing room
conditions meet those defined in UA-L-2.1.

C.	Condition the filters for at least 48 hours before post-weighing the filters.

D.	Perform post-weighing by following the procedures outlined in 7.2.2(A) through
7.2.2(M).

E.	Return the filters to their petrislide dishes and transfer to the lab supervisor
QC/QA actions and to await further analysis and/or archival.

7.3 Sentinel Filters

7.3.1.	Conditioning of Sentinel Filters

A.	Conditioning consists of acclimatizing filters to standard temperature, and humidity

conditions prior to weighing.

B.	Arrange the sentinel filters on a tray in groups of ten. Open the top of each
ziplock bag containing a single filter to allow expose to ambient conditions.

C.	Check to see that a sample ID label is placed upon each ziplock bag. Record the
date and time on the "Sentinel Filter Pre-Weighing Form" (figure 3). Place the
form with the filters during conditioning. Ensure that the computer file with the
sample ID numbers has been created in the tracking system (7.1.2. A-E) and is

marked on each form.

D.	The weighing-room must remain at standard weighing conditions for temperature,
75 °± 5°F, and humidity 50 ± 10% as outlined in the "Weighing Room Operation

and Maintenance" SOP (UA-L-2.1).

E.	Store the tray in the weigh-room conditioning locker for at least 48 hours prior to

weighing.

7.3.2.	Pre-weighing Sentinel Filters

A.	Take a batch of 10 conditioned filters from the weigh-room conditioning locker.
Check that the equilibration start date and time on the batch is at least 48 hours
prior to the current date and time.

B.	Set-up and calibrate the Mettler balance (UA-L-1.1)


-------
SOP# UA-L-9.1
Revision #1
15 May., 1999
Page: 6 of 20

C.	Turn on the computer, login, and follow the computer-balance set-up (UA-L-1.1;
7.2.3.A-C).

D.	Record the pre-weigh date, room temperature, relative humidity and technicians
initials on the filter weighing form (Figure 3).

E.	Place a plastic 30 dram vial, cleaned to specifications outlined in UA-L-5.1, on the
balance pan. Re-zero the balance for weighing by momentarily depressing the
control bar.

F.	Check that the balance reads "0.00000 g" with the doors closed (re-zero if
necessary). Remove a Sentinel teflon filter sheet from its ziplock bag. Roll the
filter sheet into a tube and then open a side door and place the filter into the 30
dram vial.

G.	Close the door and observe the illuminated stability indicator dot.

H.	Wait five to ten seconds after stability indicator dot goes out, and depress the hand
switch transferring the weight to the computer screen. Follow the instructions on
recording weights with the computer 7.5.1.A-I.

I.	Record the weight onto the "Sentinel Filter Weighing Form" (figure 3). Slight
changes in the scales environment may cause slight variations in the display.
Recorded values are valid if they reflect the displayed value at the time of the first
reading.

J. Return the filter to its ziploc bag.

K. Close the balance access doors and allow the display to return to zero. If the
display does not return to 0.00000, this may indicate zero-drift. Re-zero the
display and weigh the filter again following steps F through J.

L. Repeat steps F through K for each filter.

M. Return pre-weighed sentinel filters to the lab supervisor for QC and QA checks.

7.3.3. Post-weighing Sentinel Filters

A.	Upon assignment to the lab after field sampling, open the ziplock bags and place
onto a tray for post-conditioning. Record the sample ID#'s along with the date
and time on the "Sentinel Teflon Filter Post Weighing Backup Form" (figure 4) A
computer file with the sample ID numbers is created within the tracking system
(UA-D-28.0).

B.	Place the "Sentinel Teflon Filter Post Weighing Backup Form" (figure 4) with the
filtwers and place into the weigh-room conditioning locker. Ensure that the
weighing room conditions meet those specified in UA-L-2.1.

C.	Condition the filters for at least 48 hours under set temperature and humidity
conditions, before post-weighing the filters.

D.	After exposure in the field each filter is folded into quarters (UA-F-10.1). The
folded filter sheet is placed onto the balance rather then in the 30 dram vial during
the weighing procedure.

E.	Perform post-weighing by following the procedures outlined in 7.3.2 (A) through


-------
SOP# UA-L-9.1
Revision #1
15 May., 1999
Page: 7 of 20

(L).

F. Return the filters to their plastic ziplock bags and transfer to the lab supervisor for
QC/QA actions and to await further analysis and/or archival.

7.4 Vacuum Dust Filters

7.4.1	Conditioning Vacuum Dust Filters

A.	Conditioning consists of acclimatizing filters to standard temperature, and humidity
conditions prior to weighing.

B.	Arrange in groups of ten, bags with a vacuum dust filter and plastic cable tie in
each, onto a tray. Open each bag's ziploc to allow the interior to equilibrate with
exterior conditions.

C.	Record the pre-assigned sample ID#'s onto the "Vacuum Dust Pre-weighing
Form" (figure 5). Ensure that the computer file with the sample ID numbers has
been created in the tracking system (7.1.2. A-E) and is marked on each form.

D.	Ensure that the weighing-room is at standard weighing conditions for temperature,
75°± 5°F, and humidity 50 ± 10% as outlined in the "Weighing Room Operation
and Maintenance" SOP (UA-L-1.1).

E.	Store the tray in the weigh-room locker labeled "PRE" for at least 48 hours prior
to weighing.

7.4.2	Pre-Weighing Vacuum Dust Filters

A.	Take a batch of 10 pre-conditioned filters from the weigh room conditioning
locker. Check that the equilibration start date and time on the batch is at least 48
hours prior to the current date and time. Each filter ziploc bag contains a teflon
vacuum dust filter and a plastic cable tie.

B.	Set-up and calibrate the Mettler balance (UA-L-1.1)

C.	Turn on the computer, login, and follow the computer-balance set-up (UA-L-1.1;
7.2.3.A-C).

D.	Record the pre-weigh date, room temperature, relative humidity and technicians
initials on the "Vacuum Dust Pre-weight Form" (Figure 5).

E.	Place a plastic 30 dram vial, cleaned to specifications outlined in UA-L-5.1, on the
balance pan. Re-zero the balance.

F.	Remove a vacuum dust teflon filter sheet from its plastic sample bag and roll into a
tube which will fit into the 30 dram vial.

G.	Wait five to ten seconds after stability indicator dot goes out, and depress the hand
switch transferring the weight to the computer screen. Follow instructions on
recording weights with the computer (see 7.5.1.A-I).

H.	Record the weight onto the "Vacuum Dust Pre-weight Form" (figure 5) and
"Vacuum Dust Chain of Custody" (figure 6). Slight changes in the scales
environment may cause slight variations in the display. Recorded values are valid
if they reflect the displayed value at the time of the first reading.


-------
SOP# UA-L-9.1
Revision #1
15 May., 1999
Page: 8 of 20

I. Return the filter to its respective container with its chain of custody record.

J. Close the balance access doors and allow the display to return to zero. If the
display does not return to 0.00000, this may indicate zero-drift. Re-zero the
display and weigh the filter again following steps F through I.

K. Remove a plastic cable tie and measure following step F through J substituting
"plastic cable tie" for "filter". Record the weight on the "Vacuum Dust Pre-weight
Form" (figure 5), and "Vacuum Dust Chain of Custody" record (figure 6). Place it
in the filter bag with the weighed filter.

L. Repeat steps F through J for each filter and plastic cable tie.

M. Return pre-weighed sentinel filters to the lab supervisor for QC and QA checks.

7.4.3 Vacuum Dust Teflon Filter Post-weighing

A.	Dust filters are consigned to the lab while in the freezer after field sampling (UA-
F-7.1). Field sampling involves the pouching of the filter with the sample in the
center and the top portion secured with the weighed cable tie making a pouch
(UA-F-7.1).

B.	Transfer filter pouches to be weighed to the freezer in the lab (room 130A) and
allow to equilibrate (10 min.). Procedures for sample processing can be found in
UA-L-12.1.

C.	Take each filter one by one from the freezer, remove the sample pouch from its
ziplock bag and weigh as quickly as possible. Weigh on the Mettler AE 166
balance in the laboratory (Room 130A) to facilitate the maintenance of the samples
cold temperature.

D Allow the balance to stabilize. Record the post-weight onto the "Vacuum Dust
Characterization " form (figure 7), "Vacuum Dust Chain of Custody" form (figure
6) and the "Vacuum Dust Aliquot Chain of Custody" form (figure 8).

7.4.4 Vacuum Dust Post Sieving Filter Weighing

A.	Characterization of the vacuum dust calls for each pouch to be opened and the
material in the filter pouch removed and sieved (see UA-L-12.1 for instructions on

further processing).

B.	To determine the sieved sample weight, the cable tie and dirty filter are re-
weighed.

C.	Weigh the filter and cable tie together.

D.	Wait five to ten seconds after stability indicator dot goes out.

E.	Record the weight onto the "Vacuum Dust Characterization" form (figure 7),
"Vacuum Dust Chain of Custody" record (figure 6) and "Vacuum Dust Aliquot
Chain of Custody" record (figure 8). Slight changes in the scales environment may
cause slight variations in the display. Recorded values are valid if they reflect the

displayed value at the time of the first reading.

F.	Return each filter and cable tie to its respective container to await archival.

G.	Close the balance access doors and allow the display to return to zero. If the


-------
SOP# UA-L-9.1
Revision #1
15 May., 1999
Page: 9 of 20

display does not return to 0.00000, this may indicate zero-drift. If zero-drift is
suspected re-zero the display and weigh the filter again following steps C through
E.

H. Repeat steps C through G for each filter-cable tie pair.

Computer Operation

. 1. AE163 (#195535) balance/computer interface and computer operation

A.	The AE163 (#195535) balance in the weighing room is equipped with a computer
interface allowing the electronic recording of data from the balance display into
files containing the sample ID numbers. The programs used are validated under
protocol UA-D-2.0.

B.	Turn on the computer and type "cd\balance" to go to the "balance" sub-directory.

C.	Once in the Balance subdirectory, type "Balink Numeric Stable Right" to start
the program and setup the balance (UA-L-1.1; 7.2.3.A-C).

D.	Go to the "G:\Filters" subdirectory and type "DBASE" to start the database
program. The "G:\Filters" subdirectory is restricted to only lab personnel.

E.	From the database program find and load the file with the filter ID's, from the
"G:\filters" (UA-D-1.0) drive and subdirectory, into the database program
(7.1.2.G). The file name appears on each backup weighing forms.

F.	Follow each filter types weighing instructions (7.2.2.A-N; 7.2.3.A-G; 7.3.2.A-M;
7.3.3.A-G; 7.4.2.A-M).

G.	Weigh each filter in the order that they occur in the database file. After each 5
filters weigh one of the Class "S" calibration weights and record it under the
appropriate ID number.

H.	After the stability light goes out on the balance wait 5 seconds and press the
handswitch to transfer the weight to the computer. Upon transfer the computer
will beep. Visually check that the weight transferred is the weight appearing on
the balance display. Record the weight onto the appropriate weighing backup
form (figure 1-4, 5).

I.	The cursor will move to the next sample ID. Repeat step 5 and 6 for each sample.

J. After each group of filters is weighed and the cursor is at the end of the computer

file, save the data and return the filters to the lab supervisor for QC/QA checks.

K. The lab supervisor QC checks each filter weight against the value recorded on the
back-up form. Once completed the file is moved from "G:\Filters" to "G:\Fil-
Pre" for pre-weights or "G:\Fil-Pos" for post-weights. The "G:\Fil-Pre" and
"G:\Fil-Pos" subdirectories are restricted to lab personnel only. Each back-up
form is checked by an additional lab person to ensure that each form is completely
filled out for quality assurance.


-------
SOP# UA-L-9.1
Revision #1
15 May., 1999
Page: 10 of 20

7.6 Quality Control

7.6.1	Tolerance Limits

A.	The "Standard Weight" must be within 0.02 mg of its previously determined

weight.

B.	Lab or field blank status will be assigned by the materials technician to one out of
every 10 filters. The identification of blanks will be unknown to the lab staff
during the pre and post weighing procedure.

C.	The postweight of each batch blank must be within 0.02 mg of its initially
determined pre-weight.

D.	A visual check of individual weight values between the computer screen and the
pre- and post-weight forms will be made during the weighing procedure.

E.	To insure the accuracy of values recorded in computer files, 10% of pre- and post-
weigh forms are scanned (UA-D-24.0) and compared to recorded values.

7.6.2	Detection Limits

A.	Only the Mettler AE 163 (UA ID# A195535) and the AE 166 (UA ID# A201335)
will be used to weigh filters (table 1).

B.	The sensitivity of the Mettler AE 163 and AE 166 electrobalance is specified by
the manufacturer as 0.02 mg. Set at 0 to 30 g. the balance can read to 0.01 mg,
whereas set to read from 0 to 162 g it can be read to 0.1 mg.

C.	Record all filter weight determinations to the nearest 0.01 mg.

D.	Net filter sample weights are assumed to have a detection limit of 0.02 mg.

7.6.3	Corrective Actions

A. If the control weight (#9800007, #9800008) varies by more than + 1% from its
previous weight, recalibrate the electrobalance and re-weigh all filters in the
previous 5 filter sequence.

8.0 RECORDS

8.1 Data Collected by this Procedure

8.1.2 Filter Pre-weight and Post-weight Data

A.	The date, temperature, relative humidity, conditioning period information and
technician's initials are recorded on all Pre- and Post- filter weighing backup forms
(figures 1-5) at the beginning of all filter weighing sessions.

B.	The sample ID #, weight in grams, and status if applicable are recorded on the
filter weighing forms, and vacuum dust chain of custody forms (figures 1-6, 8).

C.	Measured results for control weights are recorded in grams on all filter weighing
forms (figures 1-8).

D.	10% of filter weighing backup forms are scanned and compared with computer
files to insure computer accuracy.


-------
SOP# UA-L-9.1
Revision #1
15 May., 1999
Page: 11 of 20

Location/Placement of Forms
2.2 Sample Weighing Forms

A.	Values recorded on weighing forms (figures 1-6) are checked against the
electronic files by the lab supervisor to ensure quality control and signs and dates
under "Q/C". An additional lab person checks that all appropriate fields are
complete and signs and dates under "Q/A" Data forms are passed to the data
coordinator and backup forms are archived in files in the lab supervisors office.

B.	A signout sheet is kept on the file cabinet to record the removal of any backup
forms. Any individual removing the files will record their name and date of
removal on the sign-out sheet.


-------
SOP# UA-L-9.1
Revision #1
15 May., 1999
Page: 12 of 20

Table 1. Balances to be used in the weighing of each filter type.

Filter Type

37 mm Teflo Pre-weigh
37 mm Teflo Post-weigh

25 mm Teflo Pre-weigh
25 mm Teflo Post-weigh

Sentinel Filter Pre-weigh
Sentinel Filter Post-weigh

Sample Type	Balance

(Computer File Suffix)

31P	AE 163

31S	AE 163

41P	AE 163

41S	AE 163

12P	AE 163

12S	AE 163

Vacuum Dust Filter Pre-weigh
Vacuum Dust Filter Post-weigh
Vacuum Dust Filter Post sieve weigh

71P

N/A
N/A

AE 163
AE 166
AE 166


-------
SOP# UA-L-9.1
Revision #1
15 May., 1999
Page: 13 of 20

Figure 1. PM Filter Pre-Weighing Form

25mm and 37mm TEFLO FILTER PRE-WEIGHING BACKUP FORM

Balance

Equilibration Start Date 	/	/	 0AE163

Equilibration Start Time [][]:[][] 0 AE 166
Weighing Date		/	/	 0#V-1200

Technician [ ] [ ]	 Temperature [ ] [ ] °F

Code Init. Relative Humidity [ ] [ ] %

File Name:		

All Weights Are Recorded In Grams (g).



Sample ID#





Weight







Status



QA/QC

[

][ ][ ][ K

][

][ ]

[ ][ ]•[ ][

][

][

]

[ ][

]

0 0

[

][ ][ ][ ][

][

][ ]

[ ][ ]•[ ][

][

][

]

[ ][

]

0 0

[

][ ][ ][ ][

][

][ ]

[ ][ ]•[ ][

][

][

]

[ ][

]

0 0

[

][ ][ ][ ][

][

][ ]

[ ][ ]•[ ][

][

][

]

[ ][

]

0 0

[

][ ][ K ][

][

][ ]

[ ][ ]•[ ][

][

][

]

[ ][

]

0 0

[

][

][

][

][

][

][ ]

[ ][

]•[

][

][

][

]

[

][

]

0 0

[

][

][

][

][

][

][ ]

[ ][

]•[

][

][

][

]

[

][

]

0 0

[

][

][

][

][

][

][ ]

[ ][

].[

][

][

][

]

[

][

]

0 0

[

][

][

][

][

][

][ ]

[ ][

]•[

][

][

][

]

[

][

]

0 0

[

][

][

][

][

][

][ ]

[ ][

]•[

][

][

][

]

[

][

]

0 0

Standard Weight	_g. Number

Standard Weight	g. Number

Comments:

L-9.0-1.0


-------
SOP# UA-L-9.1
Revision #1
15 May., 1999
Page: 14 of 20

Figure 2. PM Filter Post-Weighing Form

25mm and 37mm TEFLO FILTER POST-WEIGHING FORM

Equilibration Start Date 	/	/	 Balance

Equilibration Start Time [ ][ ]:[ ][ ]	0AE163

Weighing Date		/	/	 0AE166

0 #V-1200

Technician #1 [ ][ ]	 Temperature [ ] [ ] °F

Technician #2 [ ][ ]	 Relative Humidity [ ] [ ]%

Code Init.

File Name: 			

All Weights Are Recorded In Grams (g).

Sample ID#

Standard Weight
Standard Weight

Weight

_g. Number
_g. Number

Status

QA/QC

][ ] [ It ]

0 0

][ ] [ H ]

0 0

][ ] [ K ]

0 0

][ ] [ It 1

0 0

][ ] [ K 1

0 0

][ ] [ It 1

0 0

][ ] [ ][ ]

0 0

][ ] [ ][ 1

0 0

][ ] [ ][ ]

0 0

][ ] [ ][ 1

0 0



0 0



0 0

Comments:

L-9.0-2.0


-------
SOP# UA-L-9.1
Revision #1
15 May., 1999
Page: 15 of 20

Figure 3. Sentinel Filter Pre-Weighing Form

SENTINEL FILTER PRE-WEIGHING BACK-UP FORM

Equilibration Start Date 	/	/		Balance

Equilibration Start Time [ ][ ]:[ ][ ]	0AE163

Weighing Date 	/	/		0 AE 166

0 #V-1200

Technician #1 [ ][ ]	 Temperature	[ ][ ] °F

Technician #2 [ ][ ]	 Relative Humidity	[ ][ ]%

Code Init.

File Name: 		

All Weights Are Recorded In Grams (g).



Sample ID#



Weight





Status

QA/QC

][

][ ][ ][ ][

][ ]

[ ][ ]•[ ][

][

][ ]

[ ][ ]

00

][

][ ][ ][ K

][ ]

[ ][ M ][

][

][ ]

[ ][ ]

00

][

][ ][ ][ It

][ ]

[ ][ ]•[ ][

][

][ ]

[ ][ ]

00

][

][ ][ ][ ][

][ ]

[ ][ ]•[ ][

][

][ ]

[ ][ ]

00

][

][ ][ ][ K

][ ]

[ ][ ]•[ ][

][

][ ]

[ ][ ]

00

][	][	][	][	][	It

][	][	][	][	][	][

][	][	K	][	K	][

][	][	][	][	][	It

][ ][	][ It	][	][

Standard Weight
Standard Weight

[	][	].[	][	][	][	1	I M ]

[	][	]•[	][	][	][	1	[Ml

[	][	]•[	][	][	][	1	MM

[	][	].[	][	][	][	]	I II 1

[	][	]•[	][	][	][	1	I II 1

g. Number
g. Number

00
00
00
00
00

00
00

Comments:

L-9.0-3.0


-------
SOP# UA-L-9.1
Revision #1
15 May., 1999
Page: 16 of 20

Figure 4. Sentinel Filter Post-Weighing Form

SENTINEL FILTER POST-WEIGHING BACK-UP FORM

Equilibration Start Date 	/	/		Balance

Equilibration Start Time [ ][ ]:[ ][ ]	0AE163

Weighing Date 	/	/		0 AE 166

0 #V-1200

Technician #1 [ ][ ]	 Temperature	[ ][ ] °F

Technician #2 [ ][ ]	 Relative Humidity	[ ][ ]%

Code Init.

File Name: 		

All Weights Are Recorded In Grams (g).





Sample ID#









Weight



Status

QA/QC

[

][

][ ][ ][ ][

][

]

[

][

]•[ ][ It

][ ]

[ ][ ]

00

[

][

][ ][ K It

][

]

[

][

]•[ ][ ][

][ ]

[ ][ 3

00

[

][

][ ][ ][ ][

][

]

[

][

]•[ ][ ][

][ ]

[ ][ ]

00

[

][

][ ][ K ][

][

]

[

][

]•[ ][ It

][ ]

[ ][ ]

00

[

][

][ ][ ][ ][

][

]

[

][

]•[ It ][

][ ]

[ ][ ]

00

[ ][ ][ ][ ][

][

][

]

[

][

]•[

][ ][ ][

]

[

][

]

00

[ ][ ][ ][ ][

][

][

]

[

][

]•[

][ ][ ][

]

[

][

]

00

[ ][ ][ ][ ][

][

][

]

[

][

]•[

][ 3t ][

]

[

][

]

00

[ ][ ][ ][ ][

][

][

]

[

][

]•[

][ ][ ][

]

[

][

]

00

[ ][ ][ ][ ][

][

][

]

[

][

]-[

][ ][ ][

]

[

][

]

00

Standard Weight











g-

Number









00

Standard Weight











g-

Number









00

Comments:

L-9.0-4.0


-------
SOP # UA-L-9.1
Revision #1
15 May, 1999
Page: 17 of 20

Figure 5. Vacuum Dust Filter Pre-Weighing Form

VACUUM DUST FILTER PRE-WEIGHING BACK-UP FORM

Equilibration Start Date 	/	/	 Balance

Equilibration Start Time [ ][ ]:[ ][ ]	0AE163

Technician [ ][ ]	 0AE166

Code Init.	0#V-1200

Weighing Date	/	/	 Temperature	[ ] [ ] °F

Technician [ ][ ]		Relative Humidity [ ] [ ] %

Code Init.

File Name:		

All Weights Are Recorded In Grams (g).

Sample ID#

Weight



[ ][ ][ ][ ][ 1

[ ]•[ ][

][ ][ ][

[ u

[ ][ ][ ][ ][ 1

[ ]•[ ][

][ ][ ][

[ J-L

[ ][ ][ ][ ][ 1

[ ]¦[ ][

][ ][ ][

[ J-L

[ ][ ][ ][ ][ 1

[ ]•[¦][

][ ][ ][

[ J-l

[ ][ ][ ][ ][ 1

[ ]•[ ][

][ ][ ][

I JL

[ ][ ][ ][ ][ 1

[ ]¦[ ][

][ ][ ][

[ ]•[

[ ][ ][ ][ ][ ]

[ ]¦[ ][

][ ][ ][

L J-l

[ ][ ][ ][ ][ 1

[ ]•[ ][

][ ][ ][

I J-L

[ ][ ][ ][ It ]

[ ]•[ ][

][ ][ ][

I J-L

[ ][ ][ ][ ][ ]

[ ]•[ ][

][ ][ ][

[ J-L

Tie

Status QA/QC
0 0
00
0 0
0 0
00

00
00
00
00
00

Standard Weight	g- Number

Standard Weight	g. Number

Comments:

L-9.0-5.1


-------
SOP# UA-L-9.1
Revision #1
15 May., 1999
Page: 18 of 20

Figure 6. Vacuum dust sample chain of custody form.

Sample Weights and Chain of Custody Sheet NHEXAS Arizona
Vacuum Dust Sample







QA/QC

Sample ID# :

Tech ID T

][ ] 0 0





Init. Code

Filter Weight:

g. Tie Weight:

R-

Total Weight:

Balance

0 0

Pesticide Aliquot ID#:



0 AE 163 0 0

Metals Aliquot ID#:



0 AE 166 0 0





0 V#1200

Standard Weight #:

Weight:



g. 0 0

Custody Record

Relinquished

Signature

Date

Time

Action

or Received

mo./day/yr.





[Rel] [Rec]



/ /













[Rel] [Rec]



/ /

•











[Rel] [Rec]



/ /













[Rel] [Rec]



/ /













[Rel] [Rec]



/ /













[Rel] [Rec]



/ /













[Rel] [Rec]



/ /

•











[Rel] [Rec]



/ /





L-12.0-2.0


-------
SOP# UA-L-9.1
Revision #1
15 May., 1999
Page: 19 of 20

Figure 7. Vacuum Dust Characterization Form

VACUUM DUST CHARACTERIZATION FORM

Technician	[ ][ ]	Start Date

Init. Code

[ ][ ][ ][ ][][][] [ 1

Sam£leID_____Statu^

Total Sample	Y N

	g. - 	g- = 	g-	00

Total Wt.	Filter + Tie Wt. Collected Wt.

Tech ID (Init.)	 (Code) [ ][ ] Balance [ ]AE163	[ ] AE 166

.g-"

0 0

Total Wt.	Dirty Filter + Tie Wt.	Sample Wt.

Tech ID (Init.)	 (Code) [ ][ ]	Balance [ ] AE 163 [ ] AE 166

Screen Set [ ][ ] Archive Code [ ][ ]-[ ]-[ ][ ][ ][ ][ ]

Aliquots Pesticide Sample ID# [ ][ ][ ][ ][ ][ ][ ]

	g. - 	g- = 	g-	0 0

Split Wt.	Weighing Paper Wt. Pesticide Sample Wt.

Tech. ID (Init.)	(Code) [ ][ ]	Balance [ ] AE 163 [ ] AE 166

Metals Sample ID# [ ][ ][ ][ ][ ][ ][ ]

	g. - 	g- = 	g-	0 0

Split Wt.	Weighing Paper Wt. Metals Sample Wt.

Tech. ID (Init.)	(Code) [ ][ ]	Balance [ ] AE 163 [ ] AE 166

XRF Cup # [ ][ ] XRF Form Header Completed Y [ ] N [ ]

Other Fractions

	_g. -	g- = 	g- 0 0

>10 Screen Wt.	Weighing Paper Wt.	>10 Sample Wt.

g. - 		g- = 	g- 0 0

10-230 S creen Wt. Weighing Paper Wt. 10-230 S ample Wt.

Tech. ID (Init.)	(Code) [ ][ ]	Balance [ ]AE163 [ ]AE166

QA/QC Check	Total Screened Weight 	g-	00

(	g. . 	g.)*100 =	% 0 0

Sample Wt.	Total Screened Wt.	% Dust Loss

Total Sample Aliquots	Other Fractions

Standard Wt. Number	 			

Weight		g- 	g- 			§ " ® ®

QA/QC Signature;			 Date;	/	/	

L-12.0-1.0


-------
SOP# UA-L-9.1
Revision #1
15 May., 1999
Page: 20 of 20

Figure 8. Vacuum dust aliquot chain of custody form.





Sample Protocol and Chain of Custody Sheet
NHEXAS Arizona







Vacuum Dust Aliquots





















/V/

Sample ID#



Original Sample ID# :





00



Status:

FS: HHID:







C#4)Total Wt.:

a. -(#3)

g. = (#5)

R-

00







Filter + Tie Wt.

Collected Wt.



(#4)Total Wt.:

e. -(#6)

g. = (#7)_

R-

00

Dirty Filter + Tie Wt.

Sample Wt.

00
00

Aliquot Type:
(#8)Split Wt.

Pesticides ID

e. - (#10) g.

= (#12)

R-





Weighing Paper wt.



Aliquot wt.

00
00

Aliquot Type:
(#9">Sr>lit Wt.

Metals ID:

e. -f#ll) g-

= (#13)

R-

Weighing Paper wt.
Standard Wt #: Weight:

Aliquot wt.
K-

00







Custody Record





Relinquished
or Received

Signature

Date
mo./day/yr.

Time

Action

[Rell [Rec]



/ /







[Rell [Reel



/ /







[Rell [Reel



/ /







[Rell [Reel



/ /







[Rell [Reel



/ /







[Rell [Reel



/ /







TRell [Rec]



/ /







[Rell \Rec]



/ /







[Rell [Reel



/ /







[Rell [Reel



/ /







[Rell [Reel



/ /







[Rell [Reel



/ /







[Rell [Reel



/ /







L-12.0-2.0


-------